42 CFR 493.861 - Standard; Unexpected antibody detection.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 5 2010-10-01 2010-10-01 false Standard; Unexpected antibody detection. 493.861 Section 493.861 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... for Laboratories Performing Tests of Moderate Complexity (including the Subcategory), High Complexity...
42 CFR 493.861 - Standard; Unexpected antibody detection.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 5 2011-10-01 2011-10-01 false Standard; Unexpected antibody detection. 493.861 Section 493.861 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... for Laboratories Performing Tests of Moderate Complexity (including the Subcategory), High Complexity...
42 CFR 493.959 - Immunohematology.
Code of Federal Regulations, 2010 CFR
2010-10-01
... purposes— (1) Those that perform ABO group and/or D (Rho) typing; (2) Those that perform ABO group and/or D (Rho) typing, and unexpected antibody detection; (3) Those that in addition to paragraph (a)(2) of this... Test Procedure ABO group (excluding subgroups) D (Rho) typing Unexpected antibody detection...
21 CFR 660.36 - Samples and protocols.
Code of Federal Regulations, 2010 CFR
2010-04-01
... ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.36 Samples... a cell panel intended for identification of unexpected antibodies. The sample shall be packaged as... distribution of each lot of Reagent Red Blood Cells for detection or identification of unexpected antibodies...
Kaur, Daljit; Bains, Lovenish; Kandwal, Manoj; Parmar, Indu
2017-03-01
The ultimate aim of pretransfusion testing is the acceptable survival of donor red cells in recipient's body and antibody detection plays a critical role in achieving the same. The cornerstone of antibody detection method is detecting an unexpected antibody as against the expected antibodies of ABO blood group system. Autoantibodies can also interfere with the detection of clinically significant alloantibodies. To study the frequency of alloantibodies and autoantibodies in the healthy blood donors and patient population visiting our hospital. The Column Agglutination Technology (CAT) was used for ABO RhD blood grouping, Direct Antiglobulin Test (DAT), Autocontrol (AC), Indirect Antiglobulin Test (IAT) and red cell antibody screening and the unexpected reactions in any of these tests were recorded for further evaluation. Ethylene Diamine Tetra Acetic Acid (EDTA) blood samples were used for all these tests for both blood donors and admitted patients. The CAT was exercised for the blood grouping (using ABD-Reverse Diluent cassettes) and antibody screening (using 0.8% Surgiscreen, Ortho Clinical Diagnostics Limited, USA and Low Ionic Strength Saline Ortho BLISS with AHG cassettes) on the automated immunohaematology platform ORTHO AutoVue ® Innova system (Ortho Clinical Diagnostics Limited, USA). Among all blood donors (n=6350), seven (0.11%) donors had showed unexpected reaction. Of these, four had positive antibody screen (three having naturally occuring antibodies 2=anti-M, 1=anti-Le a and 1=inconclusive) and the other three had positive DAT. Of all the patient samples (n=6136) screened for irregular red cell antibodies, four (0.06%) patients were found to have unexpected reaction revealing one (0.02%) with anti-M antibody and the other three (0.05%) had autoantibodies in their serum. The combined prevalence for both blood donor and recipient population (n=12,486) was found to be 0.11% at our center. The alloimmunisation among patient population was found to be lower than many other studies worldwide as our hospital does not cater to multitransfused or transfusion dependant patients with haematological disorders and majorly elective surgery patients with no history of previous blood transfusions visit our hospital.
Bains, Lovenish; Kandwal, Manoj; Parmar, Indu
2017-01-01
Introduction The ultimate aim of pretransfusion testing is the acceptable survival of donor red cells in recipient’s body and antibody detection plays a critical role in achieving the same. The cornerstone of antibody detection method is detecting an unexpected antibody as against the expected antibodies of ABO blood group system. Autoantibodies can also interfere with the detection of clinically significant alloantibodies. Aim To study the frequency of alloantibodies and autoantibodies in the healthy blood donors and patient population visiting our hospital. Materials and Methods The Column Agglutination Technology (CAT) was used for ABO RhD blood grouping, Direct Antiglobulin Test (DAT), Autocontrol (AC), Indirect Antiglobulin Test (IAT) and red cell antibody screening and the unexpected reactions in any of these tests were recorded for further evaluation. Ethylene Diamine Tetra Acetic Acid (EDTA) blood samples were used for all these tests for both blood donors and admitted patients. The CAT was exercised for the blood grouping (using ABD-Reverse Diluent cassettes) and antibody screening (using 0.8% Surgiscreen, Ortho Clinical Diagnostics Limited, USA and Low Ionic Strength Saline Ortho BLISS with AHG cassettes) on the automated immunohaematology platform ORTHO AutoVue® Innova system (Ortho Clinical Diagnostics Limited, USA). Results Among all blood donors (n=6350), seven (0.11%) donors had showed unexpected reaction. Of these, four had positive antibody screen (three having naturally occuring antibodies 2=anti-M, 1=anti-Lea and 1=inconclusive) and the other three had positive DAT. Of all the patient samples (n=6136) screened for irregular red cell antibodies, four (0.06%) patients were found to have unexpected reaction revealing one (0.02%) with anti-M antibody and the other three (0.05%) had autoantibodies in their serum. Conclusion The combined prevalence for both blood donor and recipient population (n=12,486) was found to be 0.11% at our center. The alloimmunisation among patient population was found to be lower than many other studies worldwide as our hospital does not cater to multitransfused or transfusion dependant patients with haematological disorders and majorly elective surgery patients with no history of previous blood transfusions visit our hospital. PMID:28511387
Development of enhancing agglutination reaction using gold nanoparticle for pre-transfusion testing.
Choktaweesak, N; Krasathong, P; Ammaranond, P
2016-10-01
To explore an alternative way for antibody detection testing, the examination of gold nanoparticle solution for enhancing unexpected antibodies for pre-transfusion testing was investigated. Exposure of foreign antigens on red blood cells from transfusion can trigger the immune system to produce unexpected antibodies. This immunological response may cause the complication to future transfusion. For detection of unexpected antibodies, the antibody screening test is performed approximately 30-60 min. To reduce turnaround time, enhancing reagent, low-ionic strength solution (LISS), is widely used. However, cost of enhancing reagent is an issue which has concerned in resource limited countries. Gold nanoparticle solution can increase red blood cells agglutination reaction. To solve this issue, study of gold nanoparticle solution was investigated. Samples were performed comparing between LISS and gold nanoparticle solution at antiglobulin phase. After reading the agglutination reaction, supernatants were collected and measured at the optical density at 760 nm by spectrophotometer. The optical density in the tube of gold nanoparticle solution was higher than in the tube of 2-5% cell suspension and monoclonal antibody. It has been observed that gold nanoparticle solution enhanced the reaction of agglutination 98% while LISS enhanced the agglutination only 60·8%. Employing a commercially available enhancing reagent, parallel samples confirmed results providing validation of the assay. It approximately costs $1 US dollars compared to $30 for a commercially available reagent. The low cost and yet effective time-consuming test for antibody screening is a practical and viable solution alternative way for performing in antibody screening test in resource limited countries. © 2016 British Blood Transfusion Society.
USDA-ARS?s Scientific Manuscript database
Objectives. Prominent nuclear immunohistochemical staining of a PCV-2 free porcine kidney cell line (PK-15) was detected with a rabbit polyclonal antibody produced against a conserved PCV2 Rep-protein peptide. This unexpected finding led us to retrospectively test sera from gnotobiotic pigs for the ...
Anti-P1: the most common unexpected antibodies in northeastern-Thais.
Romphruk, A V; Wanhagij, C; Akahat, J; Tantanapornkul, P; Anuphan, T; Pattayaso, P; Puapairoj, C
1999-08-01
The prevalence of unexpected antibodies in the Northeastern-Thai population was studied. Sera were collected from 25,673 blood donors including 18,209 males and 7,464 females. The sera were screened for unexpected antibodies by saline and enzyme techniques. The sera which gave a positive antibody screening test were identified for specificity of antibody. The result demonstrated that 3,928 from 25,673 samples (15.30%) were positive for the antibody screening test and only 3,883 samples could be identified for specificity of antibody. The most common unexpected antibodies were anti-P1, anti-lewis and anti-P1 + anti-lewis with the frequency of 70.8, 18.6 and 10.1 per cent, respectively. The prevalence of anti-P1 in this study was higher than that reported in Central Thailand and Southeast Asia which may due to the high prevalence of liver fluke infection in the Northeastern-Thai population.
Code of Federal Regulations, 2014 CFR
2014-04-01
... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.34 Processing. (a... required blood group antigens specified in the labeling as present. (b) Products prepared from pooled red blood cells. If the product is recommended for the detection of unexpected antibodies, the pool shall be...
Code of Federal Regulations, 2011 CFR
2011-04-01
... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.34 Processing. (a... required blood group antigens specified in the labeling as present. (b) Products prepared from pooled red blood cells. If the product is recommended for the detection of unexpected antibodies, the pool shall be...
Code of Federal Regulations, 2012 CFR
2012-04-01
... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.34 Processing. (a... required blood group antigens specified in the labeling as present. (b) Products prepared from pooled red blood cells. If the product is recommended for the detection of unexpected antibodies, the pool shall be...
Code of Federal Regulations, 2013 CFR
2013-04-01
... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.34 Processing. (a... required blood group antigens specified in the labeling as present. (b) Products prepared from pooled red blood cells. If the product is recommended for the detection of unexpected antibodies, the pool shall be...
Omura, Mako; Furuya, Koji; Kudo, Shinichi; Sugiura, Wataru; Azuma, Hiroshi
2007-02-01
Encephalitozoon cuniculi, a spore-forming obligate intracellular parasitic pathogen belonging to the phylum Microsporidia, has a unique and highly specialized organelle called the polar tube. Using an enzyme immunostaining assay in which germinated E. cuniculi spores were coated onto plastic surfaces, we tested healthy and human immunodeficiency virus (HIV)-infected individuals in Japan for anti-polar tube antibodies of each immunoglobulin (Ig) class. Anti-polar tube IgG was detected in just 4 of 380 healthy individuals; no anti-polar tube IgA was detected in any individuals; however, unexpectedly, anti-polar tube IgM antibodies were detected in 138 individuals (36%). When the healthy individuals were grouped by age, the highest rate of positivity to anti-polar tube IgM antibodies was seen in individuals aged 20 years old or younger. Fifty-nine percent (24/41) of the individuals aged 20 years or younger were anti-polar tube IgM antibody positive. This rate tended to decrease among individuals in older age groups. However, no anti-polar tube IgM antibodies were detected in 21 HIV-infected persons who were younger than 30 years of age and who had CD4 cell levels below 250/mul. These seroepidemiological results clearly indicate that circulating anti-polar tube IgM antibodies that are capable of strongly reacting with filaments extruded from geminated spores exist and suggest that such antibodies may play a part in protective immunity.
Barlough, J E; Jacobson, R H; Sorresso, G P; Lynch, T J; Scott, F W
1986-07-01
A total of 2238 feline serum samples submitted to the New York State Diagnostic Laboratory over a 1-year period were tested for the presence of coronavirus antibodies, using the computer-assisted, kinetics-based enzyme-linked immunosorbent assay (KELA). Cats from which sera were obtained were categorized by sex, age, breed, and disease status, and variations in mean antibody titers for different sub-classifications within each category were analyzed by computerized statistical analysis. As expected, higher mean antibody titers were recorded for cats with feline infectious peritonitis, and for cats with a recent history of possible coronavirus exposure. However, an unexpected inverse relationship between coronavirus antibody titer and age was also found. Certain cattery-oriented pure breeds appeared to have higher mean antibody titers, because their sample populations contained a higher percentage of younger cats and cats of unknown age-groups which, over-all, had higher mean titers. Taken together, the data substantiated the efficacy of the computer-assisted KELA for routine detection of serum coronavirus antibodies in cats.
Code of Federal Regulations, 2010 CFR
2010-04-01
... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.34 Processing. (a... blood cells. If the product is recommended for the detection of unexpected antibodies, the pool shall be prepared by combining equal amounts of cells from no more than two donors. Umbilical cord cells are exempt...
Makroo, Raj Nath; Bhatia, Aakanksha; Hegde, Vikas; Chowdhry, Mohit; Thakur, Uday Kumar; Rosamma, N L
2014-09-01
The development of alloantibodies can significantly complicate transfusion therapy and results in difficulties in cross-matching of blood. Most literature on alloimmunization is limited to multitransfused individuals, with very few studies on the general hospital patients. This study was aimed at assessing the frequency and type of unexpected red cell antibodies in the general patient population at a multispecialty tertiary care centre in New Delhi, India. The results of 49,077 antibody screening tests carried out on patients, from January 2009 to December 2012 were analyzed. The clinical and transfusion records were reviewed. The data were compiled and statistically analysed. A total of 49,077 (29,917; 60.96% males and 19,160; 39.04% females) patient samples were screened for the presence of unexpected antibodies. Antibody screening was positive in 403 patients (0.82%). In the serum samples of 164 patients only autoantibodies were identified, 27 revealed autoantibodies with one or more underlying alloantibodies, while 212 patients had only alloantibody/ies in their serum. The overall alloimmunization rate was 0.49 per cent. Antibodies against the Rh system were the most frequent (64.1%), the most common alloantibody identified being anti E (37.2%), followed by anti D (19.2%). Since clinically significant antibodies are frequently detected in our patient population, antibody screening and if required, identification is the need of the hour. Since antibodies against the common Rh and Kell blood group antigens are the most frequent, provision of Rh and Kell matched red cells may be of protective value.
21 CFR 660.36 - Samples and protocols.
Code of Federal Regulations, 2014 CFR
2014-04-01
..., whenever a new donor is used, a sample of red blood cells from each new donor used in a cell panel intended... ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.36 Samples... distribution of each lot of Reagent Red Blood Cells for detection or identification of unexpected antibodies...
21 CFR 660.36 - Samples and protocols.
Code of Federal Regulations, 2013 CFR
2013-04-01
..., whenever a new donor is used, a sample of red blood cells from each new donor used in a cell panel intended... ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.36 Samples... distribution of each lot of Reagent Red Blood Cells for detection or identification of unexpected antibodies...
21 CFR 660.36 - Samples and protocols.
Code of Federal Regulations, 2012 CFR
2012-04-01
..., whenever a new donor is used, a sample of red blood cells from each new donor used in a cell panel intended... ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.36 Samples... distribution of each lot of Reagent Red Blood Cells for detection or identification of unexpected antibodies...
Morales, María A; Fabbri, Cintia M; Zunino, Gabriel E; Kowalewski, Martín M; Luppo, Victoria C; Enría, Delia A; Levis, Silvana C; Calderón, Gladys E
2017-02-01
Several medically important mosquito-borne flaviviruses have been detected in Argentina in recent years: Dengue (DENV), St. Louis encephalitis (SLEV), West Nile (WNV) and Yellow Fever (YFV) viruses. Evidence of Bussuquara virus (BSQV) and Ilheus virus (ILHV) activity were found, but they have not been associated with human disease. Non-human primates can act as important hosts in the natural cycle of flaviviruses and serological studies can lead to improved understanding of virus circulation dynamics and host susceptibility. From July-August 2010, we conducted serological and molecular surveys in free-ranging black howlers (Alouatta caraya) captured in northeastern Argentina. We used 90% plaque-reduction neutralization tests (PRNT90) to analyze 108 serum samples for antibodies to WNV, SLEV, YFV, DENV (serotypes 1and 3), ILHV, and BSQV. Virus genome detection was performed using generic reverse transcription (RT)-nested PCR to identify flaviviruses in 51 antibody-negative animals. Seventy animals had antibodies for one or more flaviviruses for a total antibody prevalence of 64.8% (70/108). Monotypic (13/70, 19%) and heterotypic (27/70, 39%) patterns were differentiated. Specific neutralizing antibodies against WNV, SLEV, DENV-1, DENV-3, ILHV, and BSQV were found. Unexpectedly, the highest flavivirus antibody prevalence detected was to WNV with 9 (8.33%) monotypic responses. All samples tested by (RT)-nested PCR were negative for viral genome. This is the first detection of WNV-specific antibodies in black howlers from Argentina and the first report in free-ranging non-human primates from Latin-American countries. Given that no animals had specific neutralizing antibodies to YFV, our results suggest that the study population remains susceptible to YFV. Monitoring of these agents should be strengthened to detect the establishment of sylvatic cycles of flaviviruses in America and evaluate risks to wildlife and human health.
Economic and workflow analysis of a blood bank automated system.
Shin, Kyung-Hwa; Kim, Hyung Hoi; Chang, Chulhun L; Lee, Eun Yup
2013-07-01
This study compared the estimated costs and times required for ABO/Rh(D) typing and unexpected antibody screening using an automated system and manual methods. The total cost included direct and labor costs. Labor costs were calculated on the basis of the average operator salaries and unit values (minutes), which was the hands-on time required to test one sample. To estimate unit values, workflows were recorded on video, and the time required for each process was analyzed separately. The unit values of ABO/Rh(D) typing using the manual method were 5.65 and 8.1 min during regular and unsocial working hours, respectively. The unit value was less than 3.5 min when several samples were tested simultaneously. The unit value for unexpected antibody screening was 2.6 min. The unit values using the automated method for ABO/Rh(D) typing, unexpected antibody screening, and both simultaneously were all 1.5 min. The total cost of ABO/Rh(D) typing of only one sample using the automated analyzer was lower than that of testing only one sample using the manual technique but higher than that of testing several samples simultaneously. The total cost of unexpected antibody screening using an automated analyzer was less than that using the manual method. ABO/Rh(D) typing using an automated analyzer incurs a lower unit value and cost than that using the manual technique when only one sample is tested at a time. Unexpected antibody screening using an automated analyzer always incurs a lower unit value and cost than that using the manual technique.
Naturally acquired antibodies against Clostridium perfringens epsilon toxin in goats.
Veschi, Josir Laine A; Bruzzone, Octavio A; Losada-Eaton, Daniela M; Dutra, Iveraldo S; Fernandez-Miyakawa, Mariano E
2008-09-15
Clostridium perfringens type D-producing epsilon toxin is a common cause of death in sheep and goats worldwide. Although anti-epsilon toxin serum antibodies have been detected in healthy non-vaccinated sheep, the information regarding naturally acquired antibodies in ruminants is scanty. The objective of the present report was to characterize the development of naturally acquired antibodies against C. perfringens epsilon toxin in goats. The levels of anti-epsilon toxin antibodies in blood serum of goat kids from two different herds were examined continuously for 14 months. Goats were not vaccinated against any clostridial disease and received heterologous colostrums from cows that were not vaccinated against any clostridial disease. During the survey one of these flocks suffered an unexpectedly severe C. perfringens type D enterotoxemia outbreak. The results showed that natural acquired antibodies against C. perfringens epsilon toxin can appear as early as 6 weeks in young goats and increase with the age without evidence of clinical disease. The enterotoxemia outbreak was coincident with a significant increase in the level of anti-epsilon toxin antibodies.
Horling, L; Neuhuber, W L; Raab, M
2012-02-15
Highly sensitive immunohistochemical detection systems such as tyramide signal amplification (TSA) are widely used, since they allow using two primary antibodies raised in the same species. Most of them are based on the streptavidin-biotin-peroxidase system and include streptavidin-coupled secondary antibodies. Using TSA in cryostat-sectioned tissues of mouse esophagus, we were puzzled by negative controls with unexpected staining mostly in the ganglionic areas. This prompted us to search for the causing agent and to include also other parts of the mouse gastrointestinal tract for comparison. Streptavidin-coupled antibodies bound to endogenous binding sites yet to be characterized, which are present throughout the mouse intestines. Staining was mainly localized around neuronal cell bodies of enteric ganglia. Thus, caution is warranted when applying streptavidin-coupled antibodies in the mouse gastrointestinal tract. The use of endogenous biotin-blocking kits combined with a prolonged post-fixation time could significantly reduce unintentional staining. Copyright © 2011 Elsevier B.V. All rights reserved.
Natural and cross-inducible anti-SIV antibodies in Mauritian cynomolgus macaques
Li, Hongzhao; Nykoluk, Mikaela; Li, Lin; Liu, Lewis R.; Omange, Robert W.; Soule, Geoff; Schroeder, Lukas T.; Toledo, Nikki; Kashem, Mohammad Abul; Correia-Pinto, Jorge F.; Liang, Binhua; Schultz-Darken, Nancy; Alonso, Maria J.; Whitney, James B.; Plummer, Francis A.
2017-01-01
Cynomolgus macaques are an increasingly important nonhuman primate model for HIV vaccine research. SIV-free animals without pre-existing anti-SIV immune responses are generally needed to evaluate the effect of vaccine-induced immune responses against the vaccine epitopes. Here, in order to select such animals for vaccine studies, we screened 108 naïve female Mauritian cynomolgus macaques for natural (baseline) antibodies to SIV antigens using a Bio-Plex multiplex system. The antigens included twelve 20mer peptides overlapping the twelve SIV protease cleavage sites (-10/+10), respectively (PCS peptides), and three non-PCS Gag or Env peptides. Natural antibodies to SIV antigens were detected in subsets of monkeys. The antibody reactivity to SIV was further confirmed by Western blot using purified recombinant SIV Gag and Env proteins. As expected, the immunization of monkeys with PCS antigens elicited anti-PCS antibodies. However, unexpectedly, antibodies to non-PCS peptides were also induced, as shown by both Bio-Plex and Western blot analyses, while the non-PCS peptides do not share sequence homology with PCS peptides. The presence of natural and vaccine cross-inducible SIV antibodies in Mauritian cynomolgus macaques should be considered in animal selection, experimental design and result interpretation, for their best use in HIV vaccine research. PMID:28982126
Shirai, Takushi; Sano, Tasuku; Kamijo, Fuminao; Saito, Nana; Miyake, Tomomi; Kodaira, Minori; Katoh, Nagaaki; Nishie, Kenichi; Okuyama, Ryuhei; Uhara, Hisashi
2016-01-01
We reported an 81-year-old woman with metastatic melanoma, in whom myasthenia gravis and rhabdomyolysis developed after nivolumab monotherapy. The first symptom of myasthenia gravis was dyspnea. Ultrasonography detected hypokinesis of the bilateral diaphragm suggesting myasthenia gravis, although there was no abnormal finding of the lungs in computed tomography images. Acetylcholine receptor binding antibodies were low-titer positive in the preserved serum before administration of nivolumab, strongly suggesting that the myasthenia gravis was a nivolumab-related immune adverse event. Despite the remarkable clinical benefits of immune checkpoint inhibitors for patients with advanced melanoma, it is important to recognize unexpected immune-related adverse events. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Apelseth, Torunn O; Kvalheim, Venny L; Kristoffersen, Einar K
2016-05-01
Allergic transfusion reactions (ATRs) present with a broad range of symptoms probably caused by mediators released from mast cells and basophil granulocytes upon activation. Passive immunoglobulin (Ig)E sensitization may yield clinical symptoms and positive allergy tests. Unexpected findings of IgE antibodies in pooled solvent/detergent (S/D)-treated plasma (Octaplas, Octapharma) during routine analysis initiated an investigation of serum proteins. Consecutive batches of S/D-plasma transfused during September 2014 through March 2015 were investigated for IgE, IgG, IgA IgM, C3, C4, haptoglobin, anti-nuclear antibodies (ANAs), and red blood cell (RBC) antibodies. During the study period, 4203 S/D-plasma units were transfused. Nineteen (14 Octaplas A and five Octaplas AB) of 20 batches of S/D-plasma were included, representing 99.9% of total number of plasma units. A total of 0.4% of units and five batches reported ATRs. Concentrations of total IgE higher than expected values in adults (<120 kU/L) were observed in 18 of the 19 (95%) batches investigated (median concentration [quartiles], 161 [133-183]). Specific IgE antibodies (expected < 0.35 kilounits antigen [kUA]/L) against house dust mite (2.52 [1.01-5.09]), timothy (2.83 [2.48-3.24]), cat (1.13 [0.58-1.52]), dog (0.83 [0.50-1.05]), mugwort (0.69 [0.53-0.97]), birch (0.62 [0.28-0.92]), peanut (0.52 [0.29-075]), wheat (0.46 [0.33-0.69]), and latex (0.32 [0.21-0.53]) were also detected. IgG, IgA, IgM, C3, C4, and haptoglobin were within or below normal ranges. No RBC antibodies were observed, but 18% of batches showed low levels of ANA (anti-RNP). Specific IgE antibodies against airborne allergens, food allergens, and latex were detected in S/D-treated pooled plasma. © 2016 AABB.
Caldas, Cristina; Coelho, Verônica; Kalil, Jorge; Moro, Ana Maria; Maranhão, Andrea Q; Brígido, Marcelo M
2003-05-01
Humanization of monoclonal antibodies by complementary determinant region (CDR)-grafting has become a standard procedure to improve the clinical usage of animal antibodies. However, antibody humanization may result in loss of activity that has been attributed to structural constraints in the framework structure. In this paper, we report the complete humanization of the 6.7 anti-human CD18 monoclonal antibody in a scFv form. We used a germline-based approach to design a humanized VL gene fragment and expressed it together with a previously described humanized VH. The designed humanized VL has only 14 mutations compared to the closest human germline sequence. The resulting humanized scFv maintained the binding capacity and specificity to human CD18 expressed on the cell surface of peripheral blood mononuclear cells (PBMC), and showed the same pattern of staining T-lymphocytes sub-populations, in comparison to the original monoclonal antibody. We observed an unexpected effect of a conserved mouse-human framework position (L37) that hinders the binding of the humanized scFv to antigen. This paper reveals a new framework residue that interferes with paratope and antigen binding and also reinforces the germline approach as a successful strategy to humanize antibodies.
Doritchamou, Justin; Arango, Eliana M.; Cabrera, Ana; Arroyo, Maria Isabel; Kain, Kevin C.; Ndam, Nicaise Tuikue; Maestre, Amanda
2014-01-01
In pregnancy, parity-dependent immunity is observed in response to placental infection with Plasmodium falciparum. Antibodies recognize the surface antigen, VAR2CSA, expressed on infected red blood cells and inhibit cytoadherence to the placental tissue. In most settings of malaria endemicity, antibodies against VAR2CSA are predominantly observed in multigravid women and infrequently in men, children, and nulligravid women. However, in Colombia, we detected antibodies against multiple constructs of VAR2CSA among men and children with acute P. falciparum and Plasmodium vivax infection. The majority of men and children (>60%) had high levels of IgGs against three recombinant domains of VAR2CSA: DBL5ε, DBL3X, and ID1-ID2. Surprisingly, these antibodies were observed only in pregnant women, men, and children exposed either to P. falciparum or to P. vivax. Moreover, the anti-VAR2CSA antibodies are of high avidity and efficiently inhibit adherence of infected red blood cells to chondroitin sulfate A in vitro, suggesting that they are specific and functional. These unexpected results suggest that there may be genotypic or phenotypic differences in the parasites of this region or in the host response to either P. falciparum or P. vivax infection outside pregnancy. These findings may hold significant clinical relevance to the pathophysiology and outcome of malaria infections in this region. PMID:24686068
Chow, Nancy A; Lindsley, Mark D; McCotter, Orion Z; Kangiser, Dave; Wohrle, Ron D; Clifford, Wayne R; Yaglom, Hayley D; Adams, Laura E; Komatsu, Kenneth; Durkin, Michelle M; Baker, Rocky J; Shubitz, Lisa F; Derado, Gordana; Chiller, Tom M; Litvintseva, Anastasia P
2017-01-01
Coccidioides is a soil-dwelling fungus that causes coccidioidomycosis, a disease also known as Valley fever, which affects humans and a variety of animal species. Recent findings of Coccidioides in new, unexpected areas of the United States have demonstrated the need for a better understanding of its geographic distribution. Large serological studies on animals could provide important information on the geographic distribution of this pathogen. To facilitate such studies, we used protein A/G, a recombinant protein that binds IgG antibodies from a variety of mammalian species, to develop an enzyme immunoassay (EIA) that detects IgG antibodies against Coccidioides in a highly sensitive and high-throughput manner. We showed the potential of this assay to be adapted to multiple animal species by testing a collection of serum and/or plasma samples from dogs, mice, and humans with or without confirmed coccidioidomycosis. We then evaluated the performance of the assay in dogs, using sera from dogs residing in a highly endemic area, and found seropositivity rates significantly higher than those in dogs of non-endemic areas. We further evaluated the specificity of the assay in dogs infected with other fungal pathogens known to cross-react with Coccidioides. Finally, we used the assay to perform a cross-sectional serosurvey investigating dogs from Washington, a state in which infection with Coccidioides has recently been documented. In summary, we have developed a Coccidioides EIA for the detection of antibodies in canines that is more sensitive and has higher throughput than currently available methods, and by testing this assay in mice and humans, we have shown a proof of principle of its adaptability for other animal species.
Lindsley, Mark D.; McCotter, Orion Z.; Kangiser, Dave; Wohrle, Ron D.; Clifford, Wayne R.; Yaglom, Hayley D.; Adams, Laura E.; Komatsu, Kenneth; Durkin, Michelle M.; Baker, Rocky J.; Shubitz, Lisa F.; Derado, Gordana; Chiller, Tom M.; Litvintseva, Anastasia P.
2017-01-01
Coccidioides is a soil-dwelling fungus that causes coccidioidomycosis, a disease also known as Valley fever, which affects humans and a variety of animal species. Recent findings of Coccidioides in new, unexpected areas of the United States have demonstrated the need for a better understanding of its geographic distribution. Large serological studies on animals could provide important information on the geographic distribution of this pathogen. To facilitate such studies, we used protein A/G, a recombinant protein that binds IgG antibodies from a variety of mammalian species, to develop an enzyme immunoassay (EIA) that detects IgG antibodies against Coccidioides in a highly sensitive and high-throughput manner. We showed the potential of this assay to be adapted to multiple animal species by testing a collection of serum and/or plasma samples from dogs, mice, and humans with or without confirmed coccidioidomycosis. We then evaluated the performance of the assay in dogs, using sera from dogs residing in a highly endemic area, and found seropositivity rates significantly higher than those in dogs of non-endemic areas. We further evaluated the specificity of the assay in dogs infected with other fungal pathogens known to cross-react with Coccidioides. Finally, we used the assay to perform a cross-sectional serosurvey investigating dogs from Washington, a state in which infection with Coccidioides has recently been documented. In summary, we have developed a Coccidioides EIA for the detection of antibodies in canines that is more sensitive and has higher throughput than currently available methods, and by testing this assay in mice and humans, we have shown a proof of principle of its adaptability for other animal species. PMID:28380017
Iida, Midori; Inamura, Noboru; Takeuchi, Makoto
2006-01-01
Newborn case of maternal anti-SSA antibody-induced congenital complete heart block (CCHB) accompanying cardiomyopathy is presented. Unexpectedly, she died of ventricular tachycardia, not bradycardia, 6 days after birth. Autopsy revealed left ventricular cardiomyopathy with endocardial fibroelastosis. Thus, when evaluating fetal cardiac performance in cases of maternal anti-SSA antibody-induced CCHB, it is necessary to pay attention to myocardial attributes such as endocardial hyperplasia.
Opening the file drawer: Unexpected insights from a chytrid infection experiment.
Byrne, Allison Q; Poorten, Thomas J; Voyles, Jamie; Willis, Craig K R; Rosenblum, Erica Bree
2018-01-01
Infection experiments are critical for understanding wildlife disease dynamics. Although infection experiments are typically designed to reduce complexity, disease outcomes still result from complex interactions between host, pathogen, and environmental factors. Cryptic variation across factors can lead to decreased repeatability of infection experiments within and between research groups and hinder research progress. Furthermore, studies with unexpected results are often relegated to the "file drawer" and potential insights gained from these experimental outcomes are lost. Here, we report unexpected results from an infection experiment studying the response of two differentially-susceptible but related frogs (American Bullfrog Rana catesbeiana and the Mountain yellow-legged frog Rana muscosa) to the amphibian-killing chytrid fungus (Batrachochytrium dendrobatidis, Bd). Despite well-documented differences in susceptibility between species, we found no evidence for antibody-mediated immune response and no Bd-related mortality in either species. Additionally, during the study, the sham-inoculated R. catesbeiana control group became unexpectedly Bd-positive. We used a custom genotyping assay to demonstrate that the aberrantly-infected R. catesbeiana carried a Bd genotype distinct from the inoculation genotype. Thus R. catesbeiana individuals were acquired with low-intensity infections that could not be detected with qPCR. In the Bd-inoculated R. catesbeiana treatment group, the inoculated genotype appeared to out-compete the cryptic infection. Thus, our results provide insight into Bd coinfection dynamics, a phenomenon that is increasingly relevant as different pathogen strains are moved around the globe. Our experiment highlights how unexpected experimental outcomes can serve as both cautionary tales and opportunities to explore unanswered research questions. We use our results as a case study to highlight common sources of anomalous results for infection experiments. We argue that understanding these factors will aid researchers in the design, execution, and interpretation of experiments to understand wildlife disease processes.
Klaver, Andrea C; Coffey, Mary P; Bennett, David A; Loeffler, David A
2017-01-01
Tau vaccination and administration of anti-tau antibodies can prevent pathology and cognitive impairment in transgenic mouse models of tauopathy, suggesting that therapies which increase anti-tau antibodies might slow the development and/or progression of Alzheimer's disease (AD). The extent to which individuals with no cognitive impairment (NCI) possess serum anti-tau antibodies, and whether their concentrations of these antibodies differ from anti-tau antibody levels in persons with mild cognitive impairment (MCI) or AD, are unclear. Previous studies measuring these antibodies did not account for antibody polyvalent binding, which can be extensive, nor that antibody binding to phosphorylated tau peptides could be due to binding to non-phosphorylated epitopes on those peptides. An ELISA controlling for these factors was used to measure the specific binding of serum IgG and IgM to phosphorylated ("pTau;" phosphorylated at Serine-199 and Serine-202) and non-phosphorylated ("non-pTau") tau 196-207 in subjects with NCI, MCI, or AD ( n = 10/group). Between-group differences in these antibody levels were evaluated for statistical significance, and correlations were examined in pooled data from all subjects between these antibody levels and subject age, global cognitive functioning, and NFT counts. Specific IgG binding to pTau and non-pTau was detected in all subjects except for one NCI control. Specific IgM binding was detected to pTau in all subjects except for two AD patients, and to non-pTau in all subjects. Mean pTau IgG was increased in MCI subjects by 53% and 70% vs. AD and NCI subjects respectively (both p < 0.05), while no significant differences were found between groups for non-pTau IgG ( p = 0.052), pTau IgM, or non-pTau IgM. Non-pTau IgG was negatively associated with global cognition (Spearman rho = -0.50). Specific binding of serum IgG and IgM to phosphorylated and non-phosphorylated tau may be present in older persons regardless of their cognitive status. Serum IgG to phosphorylated tau may be increased in individuals with MCI, but this unexpected finding requires confirmation. The approach used in this study to measure specific serum antibodies to phosphorylated tau should be useful for measuring antibodies to other post-translationally-modified proteins that are of relevance to neurodegenerative disorders.
Menon, S; Stansfield, S H; Walsh, M; Hope, E; Isaia, L; Righarts, A A; Niupulusu, T; Temese, S V A; Iosefa-Siitia, L; Auvaa, L; Tapelu, S A; Motu, M F; Suaalii-Sauni, T; Timms, P; Hill, P C; Huston, W M
2016-04-21
In our recent village-based cross-sectional study, the prevalence of nucleic acid amplification technique (NAAT) diagnosed Chlamydia trachomatis (CT) in sexually active Samoan women was very high (36 %), and test positivity was associated with sub-fertility. We conducted a serological and epidemiological analysis in these participants to identify if serological data can provide further insight into the potential contribution of CT to sub-fertility in this population. Serological prediction of CT associated sub-fertility was conducted using a series of commercial tests. The correlation between fertility or sub-fertility, behavioral factors, and serologically predicted CT associated sub-fertility was determined. A positive antibody reaction against the Chlamydia Major Outer Membrane Protein (MOMP) was significantly associated with sub-fertility, with 50 % of infertile women being positive. Serum IgG and IgA antibodies against MOMP correlated with current infection measured by urine NAAT, suggesting longer term infections are common in this population. Chlamydia pneumoniae antibodies were frequently detected in this population (84 %), and unexpectedly, were significantly associated with sub-fertility. The high prevalence of chlamydial infection and of positive chlamydial sub-fertility results suggests that CT is an important and frequent contributory factor to sub-fertility in this population.
Domingo, Cristina; Escadafal, Camille; Rumer, Leonid; Méndez, Jairo A.; García, Paquita; Sall, Amadou A.; Teichmann, Anette; Donoso-Mantke, Oliver; Niedrig, Matthias
2012-01-01
Objective We describe an external quality assurance (EQA) study designed to assess the efficiency and accurateness of molecular and serological methods used by expert laboratories performing YF diagnosis. Study Design For molecular diagnosis evaluation, a panel was prepared of 14 human plasma samples containing specific RNA of different YFV strains (YFV-17D, YFV South American strain [Brazil], YFV IvoryC1999 strain), and specificity samples containing other flaviviruses and negative controls. For the serological panel, 13 human plasma samples with anti-YFV-specific antibodies against different strains of YFV (YFV-17D strain, YFV IvoryC1999 strain, and YFV Brazilian strain), as well as specificity and negative controls, were included. Results Thirty-six laboratories from Europe, the Americas, Middle East, and Africa participated in these EQA activities. Only 16% of the analyses reported met all evaluation criteria with optimal performance. Serial dilutions of YFV-17D showed that in general the methodologies reported provided a suitable sensitivity. Failures were mainly due to the inability to detect wild-type strains or the presence of false positives. Performance in the serological diagnosis varied, mainly depending on the methodology used. Anti-YFV IgM detection was not performed in 16% of the reports using IIF or ELISA techniques, although it is preferable for the diagnosis of YFV acute infections. A good sensitivity profile was achieved in general; however, in the detection of IgM antibodies a lack of sensitivity of anti-YFV antibodies against the vaccine strain 17D was observed, and of the anti-YFV IgG antibodies against a West African strain. Neutralization assays showed a very good performance; however, the unexpected presence of false positives underlined the need of improving the running protocols. Conclusion This EQA provides information on each laboratory's efficacy of RT-PCR and serological YFV diagnosis techniques. The results indicate the need for improving serological and molecular diagnosis techniques and provide a follow-up of the diagnostic profiles. PMID:22570700
Domingo, Cristina; Escadafal, Camille; Rumer, Leonid; Méndez, Jairo A; García, Paquita; Sall, Amadou A; Teichmann, Anette; Donoso-Mantke, Oliver; Niedrig, Matthias
2012-01-01
We describe an external quality assurance (EQA) study designed to assess the efficiency and accurateness of molecular and serological methods used by expert laboratories performing YF diagnosis. For molecular diagnosis evaluation, a panel was prepared of 14 human plasma samples containing specific RNA of different YFV strains (YFV-17D, YFV South American strain [Brazil], YFV IvoryC1999 strain), and specificity samples containing other flaviviruses and negative controls. For the serological panel, 13 human plasma samples with anti-YFV-specific antibodies against different strains of YFV (YFV-17D strain, YFV IvoryC1999 strain, and YFV Brazilian strain), as well as specificity and negative controls, were included. Thirty-six laboratories from Europe, the Americas, Middle East, and Africa participated in these EQA activities. Only 16% of the analyses reported met all evaluation criteria with optimal performance. Serial dilutions of YFV-17D showed that in general the methodologies reported provided a suitable sensitivity. Failures were mainly due to the inability to detect wild-type strains or the presence of false positives. Performance in the serological diagnosis varied, mainly depending on the methodology used. Anti-YFV IgM detection was not performed in 16% of the reports using IIF or ELISA techniques, although it is preferable for the diagnosis of YFV acute infections. A good sensitivity profile was achieved in general; however, in the detection of IgM antibodies a lack of sensitivity of anti-YFV antibodies against the vaccine strain 17D was observed, and of the anti-YFV IgG antibodies against a West African strain. Neutralization assays showed a very good performance; however, the unexpected presence of false positives underlined the need of improving the running protocols. This EQA provides information on each laboratory's efficacy of RT-PCR and serological YFV diagnosis techniques. The results indicate the need for improving serological and molecular diagnosis techniques and provide a follow-up of the diagnostic profiles.
Cho, Chung Y; Oles, Carolyn; Nowatzke, William; Oliver, Kerry; Garber, Eric A E
2017-10-01
The homology between proteins in legumes and tree nuts makes it common for individuals with food allergies to be allergic to multiple legumes and tree nuts. This propensity for allergenic and antigenic cross-reactivity means that commonly employed commercial immunodiagnostic assays (e.g., dipsticks) for the detection of food allergens may not always accurately detect, identify, and quantitate legumes and tree nuts unless additional orthogonal analytical methods or secondary measures of analysis are employed. The xMAP ® Multiplex Food Allergen Detection Assay (FADA) was used to determine the cross-reactivity patterns and the utility of multi-antibody antigenic profiling to distinguish between legumes and tree nuts. Pure legumes and tree nuts extracted using buffered detergent displayed a high level of cross-reactivity that decreased upon dilution or by using a buffer (UD buffer) designed to increase the stringency of binding conditions and reduce the occurrence of false positives due to plant-derived lectins. Testing for unexpected food allergens or the screening for multiple food allergens often involves not knowing the identity of the allergen present, its concentration, or the degree of modification during processing. As such, the analytical response measured may represent multiple antigens of varying antigenicity (cross-reactivity). This problem of multiple potential analytes is usually unresolved and the focus becomes the primary analyte, the antigen the antibody was raised against, or quantitative interpretation of the content of the analytical sample problematic. The alternative solution offered here to this problem is the use of an antigenic profile as generated by the xMAP FADA using multiple antibodies (bead sets). By comparing the antigenic profile to standards, the allergen may be identified along with an estimate of the concentration present. Cluster analysis of the xMAP FADA data was also performed and agreed with the known phylogeny of the legumes and tree nuts being analyzed. Graphical abstract The use of cluster analysis to compare the multi-antigen profiles of food allergens.
Constitutive NOTCH3 Signaling Promotes the Growth of Basal Breast Cancers.
Choy, Lisa; Hagenbeek, Thijs J; Solon, Margaret; French, Dorothy; Finkle, David; Shelton, Amy; Venook, Rayna; Brauer, Matthew J; Siebel, Christian W
2017-03-15
Notch ligands signal through one of four receptors on neighboring cells to mediate cell-cell communication and control cell fate, proliferation, and survival. Although aberrant Notch activation has been implicated in numerous malignancies, including breast cancer, the importance of individual receptors in distinct breast cancer subtypes and the mechanisms of receptor activation remain unclear. Using a novel antibody to detect active NOTCH3, we report here that NOTCH3 signals constitutively in a panel of basal breast cancer cell lines and in more than one third of basal tumors. Selective inhibition of individual ligands revealed that this signal does not require canonical ligand induction. A NOTCH3 antagonist antibody inhibited growth of basal lines, whereas a NOTCH3 agonist antibody enhanced the transformed phenotype in vitro and in tumor xenografts. Transcriptomic analyses generated a Notch gene signature that included Notch pathway components, the oncogene c-Myc , and the mammary stem cell regulator Id4 This signature drove clustering of breast cancer cell lines and tumors into the common subtypes and correlated with the basal classification. Our results highlight an unexpected ligand-independent induction mechanism and suggest that constitutive NOTCH3 signaling can drive an oncogenic program in a subset of basal breast cancers. Cancer Res; 77(6); 1439-52. ©2017 AACR . ©2017 American Association for Cancer Research.
Demma, Linda J; Traeger, Marc; Blau, Dianna; Gordon, Rondeen; Johnson, Brian; Dickson, Jeff; Ethelbah, Rudy; Piontkowski, Stephen; Levy, Craig; Nicholson, William L; Duncan, Christopher; Heath, Karen; Cheek, James; Swerdlow, David L; McQuiston, Jennifer H
2006-01-01
During 2002 through 2004, 15 patients with Rocky Mountain spotted fever (RMSF) were identified in a rural community in Arizona where the disease had not been previously reported. The outbreak was associated with Rickettsia rickettsii in an unexpected tick vector, the brown dog tick (Rhipicephalus sanguineus), which had not been previously associated with RMSF transmission in the United States. We investigated the extent of exposure to R. rickettsii in the local area through serologic evaluations of children and dogs in 2003-2004, and in canine sera from 1996. Antibodies to R. rickettsii at titers > or = 32 were detected in 10% of children and 70% of dogs in the outbreak community and 16% of children and 57% of dogs in a neighboring community. In comparison, only 5% of canine samples from 1996 had anti-R. rickettsii antibodies at titers > or = 32. These results suggest that exposures to RMSF have increased over the past 9 years, and that RMSF may now be endemic in this region.
Kafkas, Alexandros; Montaldi, Daniela
2015-01-01
The role of contextual expectation in processing familiar and novel stimuli was investigated in a series of experiments combining eye tracking, functional magnetic resonance imaging, and behavioral methods. An experimental paradigm emphasizing either familiarity or novelty detection at retrieval was used. The detection of unexpected familiar and novel stimuli, which were characterized by lower probability, engaged activity in midbrain and striatal structures. Specifically, detecting unexpected novel stimuli, relative to expected novel stimuli, produced greater activity in the substantia nigra/ventral tegmental area (SN/VTA), whereas the detection of unexpected familiar, relative to expected, familiar stimuli, elicited activity in the striatum/globus pallidus (GP). An effective connectivity analysis showed greater functional coupling between these two seed areas (GP and SN/VTA) and the hippocampus, for unexpected than for expected stimuli. Within this network of midbrain/striatal–hippocampal interactions two pathways are apparent; the direct SN–hippocampal pathway sensitive to unexpected novelty and the perirhinal–GP–hippocampal pathway sensitive to unexpected familiarity. In addition, increased eye fixations and pupil dilations also accompanied the detection of unexpected relative to expected familiar and novel stimuli, reflecting autonomic activity triggered by the functioning of these two pathways. Finally, subsequent memory for unexpected, relative to expected, familiar, and novel stimuli was characterized by enhanced recollection, but not familiarity, accuracy. Taken together, these findings suggest that a hippocampal–midbrain network, characterized by two distinct pathways, mediates encoding facilitation and most critically, that this facilitation is driven by contextual novelty, rather than by the absolute novelty of a stimulus. This contextually sensitive neural mechanism appears to elicit increased exploratory behavior, leading subsequently to greater recollection of the unexpected stimulus. © 2015 The Authors Hippocampus Published by Wiley Periodicals, Inc. PMID:25708843
Rix, Catherine S; Sims, Mark R; Cullen, David C
2011-11-01
The proposed ExoMars mission, due to launch in 2018, aims to look for evidence of extant and extinct life in martian rocks and regolith. Previous attempts to detect organic molecules of biological or abiotic origin on Mars have been unsuccessful, which may be attributable to destruction of these molecules by perchlorate salts during pyrolysis sample extraction techniques. Organic molecules can also be extracted and measured with solvent-based systems. The ExoMars payload includes the Life Marker Chip (LMC) instrument, capable of detecting biomarker molecules of extant and extinct Earth-like life in liquid extracts of martian samples with an antibody microarray assay. The aim of the work reported here was to investigate whether the presence of perchlorate salts, at levels similar to those at the NASA Phoenix landing site, would compromise the LMC extraction and detection method. To test this, we implemented an LMC-representative sample extraction process with an LMC-representative antibody assay and used these to extract and analyze a model sample that consisted of a Mars analog sample matrix (JSC Mars-1) spiked with a representative organic molecular target (pyrene, an example of abiotic meteoritic infall targets) in the presence of perchlorate salts. We found no significant change in immunoassay function when using pyrene standards with added perchlorate salts. When model samples spiked with perchlorate salts were subjected to an LMC-representative liquid extraction, immunoassays functioned in a liquid extract and detected extracted pyrene. For the same model sample matrix without perchlorate salts, we observed anomalous assay signals that coincided with yellow coloration of the extracts. This unexpected observation is being studied further. This initial study indicates that the presence of perchlorate salts, at levels similar to those detected at the NASA Phoenix landing site, is unlikely to prevent the LMC from extracting and detecting organic molecules from martian samples.
Carroll, Ty B; Fisco, Amy J H; Auchus, Richard J; Kennedy, Laurence; Findling, James W
2014-07-01
The use of ovine corticotropin releasing hormone (oCRH) maximizes the diagnostic accuracy of inferior petrosal sinus sampling (IPSS) in patients with adrenocorticotropin hormone (ACTH)-dependent Cushing's syndrome (CS). oCRH is marketed as ACTHrel and, understandably, may be confused with cosyntropin [ACTH (1-24)]. The inadvertent substitution of synthetic ACTH(1-24) for oCRH (ACTHrel) during IPSS may cause unexpected and misleading results. The aim of this report is to raise awareness of the potential confounding results created when synthetic ACTH(1-24) is mistakenly used during IPSS. We present 3 patients treated at 3 different centers with ACTH-dependent CS in whom ACTH(1-24) was mistakenly substituted for oCRH (ACTHrel) during IPSS. In all patients, there was an abrupt and unexpected decrease in plasma ACTH in the inferior petrosal sinus (IPS) samples after presumptive stimulation with oCRH. Re-evaluation of the patients' pharmacy records confirmed that synthetic ACTH(1-24) had been used rather than oCRH during each procedure. Because "sandwich" immunometric assays for ACTH measure the entire pool of endogenous ACTH, the administration of synthetic ACTH(1-24) artifactually decreases the endogenous plasma ACTH(1-39) measurement by binding only to the N-terminal antibody raised against ACTH(1-17) and not to the C-terminal antibody raised against ACTH(34-39). This results in a lack of a detectable sandwich complex and explains the apparent reduction in ACTH concentration. An abrupt decrease in ACTH during IPSS suggests that synthetic ACTH(1-24) rather than oCRH (ACTHrel) has been administered. The labeling of oCRH as ACTHrel poses a potential patient safety problem about which endocrinologists, interventional radiologists, and pharmacists should be aware.
2008-04-01
symptoms may have been related to endotoxin . Clinical signs in the ponies and the mule were either minimal (fever) or nonexistent. All 6 equids produced ...ponies, 1 mule, 1 donkey), natural hosts, for purposes of producing antibodies. Multiple high inocula were used in some cases. Unexpectedly SAVP1 appeared...that was experimentally infected in 6 equids (4 ponies, 1 mule, 1 donkey), natural hosts, for purposes of producing antibodies. Multiple high inocula
The detection of faked identity using unexpected questions and mouse dynamics.
Monaro, Merylin; Gamberini, Luciano; Sartori, Giuseppe
2017-01-01
The detection of faked identities is a major problem in security. Current memory-detection techniques cannot be used as they require prior knowledge of the respondent's true identity. Here, we report a novel technique for detecting faked identities based on the use of unexpected questions that may be used to check the respondent identity without any prior autobiographical information. While truth-tellers respond automatically to unexpected questions, liars have to "build" and verify their responses. This lack of automaticity is reflected in the mouse movements used to record the responses as well as in the number of errors. Responses to unexpected questions are compared to responses to expected and control questions (i.e., questions to which a liar also must respond truthfully). Parameters that encode mouse movement were analyzed using machine learning classifiers and the results indicate that the mouse trajectories and errors on unexpected questions efficiently distinguish liars from truth-tellers. Furthermore, we showed that liars may be identified also when they are responding truthfully. Unexpected questions combined with the analysis of mouse movement may efficiently spot participants with faked identities without the need for any prior information on the examinee.
Werwitzke, S; Geisen, U; Nowak-Göttl, U; Eichler, H; Stephan, B; Scholz, U; Holstein, K; Klamroth, R; Knöbl, P; Huth-Kühne, A; Bomke, B; Tiede, A
2016-05-01
Essentials Factor VIII (FVIII) binding IgG detected by ELISA could be an alternative to the Bethesda assay. We studied the performance of anti-FVIII IgG ELISA in patients with acquired hemophilia and controls. Anti-FVIII IgG > 99th percentile of controls was highly sensitive and specific. Patients with high anti-FVIII IgG have a lower chance of achieving remission. Background Acquired hemophilia A is a severe bleeding disorder that requires fast and accurate diagnosis as it occurs often unexpectedly in previously healthy men and women of every age. The Nijmegen-modified Bethesda assay is the diagnostic reference standard for detecting neutralizing autoantibodies against factor VIII (FVIII), but is not widely available, not ideal for quantifying the complex type 2 inhibitors seen in acquired hemophilia, and suffers from high inter-laboratory variability. Objectives To assess the diagnostic and prognostic value of FVIII-binding antibodies as detected by ELISA compared with the Nijmegen Bethesda assay. Methods Samples from the time of first diagnosis and clinical data were available from 102 patients with acquired hemophilia enrolled in the prospective GTH-AH 01/2010 study. Controls (n = 102) were matched for gender and age. Diagnostic cut-offs were determined by receiver-operator curve analysis. The prognostic value was assessed in 92 of the 102 patients by Cox regression analysis of time to partial remission. Results Anti-FVIII IgG above the 99th percentile (> 15 arbitrary units per mL) revealed high sensitivity and specificity (both 0.99; 95% confidence interval, 0.95-1.0) for diagnosing acquired hemophilia. The likelihood of achieving partial remission was related to anti-FVIII IgG concentration (< 300 arbitrary units, 1.0; 300-1050, 0.65; > 1050, 0.39). The Bethesda titer was only associated with the likelihood of partial remission when analyzed in the central laboratory, but not when data from local GTH study sites were used. Conclusion Although the Nijmegen-modified Bethesda assay is the reference standard for demonstrating neutralizing antibodies, the detection of FVIII-binding antibodies by ELISA is similarly sensitive and specific for diagnosing acquired hemophilia. In addition, anti-FVIII IgG may provide prognostic information. © 2016 International Society on Thrombosis and Haemostasis.
Campero, Lucía M; Moreno-Gonzalo, Javier; Venturini, María C; Moré, Gastón; Dellarupe, Andrea; Rambeaud, Magdalena; Echaide, Ignacio E; Valentini, Beatriz; Campero, Carlos M; Moore, Dadín P; Cano, Dora B; Fort, Marcelo; Mota, Rinaldo A; Serrano-Martínez, Marcos E; Cruz-Vázquez, Carlos; Ortega-Mora, Luis M; Álvarez-García, Gema
2018-01-01
We carried out an inter-laboratory trial to compare the serological tests commonly used for the detection of specific Neospora caninum antibodies in cattle in Ibero-American countries. A total of eight laboratories participated from the following countries: Argentina (n = 4), Brazil (n = 1), Peru (n = 1), Mexico (n = 1), and Spain (n = 1). A blind panel of well-characterized cattle sera (n = 143) and sera representative of the target population (n = 351) was tested by seven in-house indirect fluorescent antibody tests (IFATs 1-7) and three enzyme-linked immunosorbent assays (ELISAs 1-3; two in-house and one commercial). Diagnostic performance of the serological tests was calculated and compared according to the following criteria: (1) the "Pre-test information," which uses previous epidemiological and serological data; (2) the "Majority of tests," which classifies a serum as positive or negative according to the results obtained by most tests evaluated. Unexpectedly, six tests showed either sensitivity (Se) or specificity (Sp) values lower than 90%. In contrast, the best tests in terms of Se, Sp, and area under the ROC curve (AUC) values were IFAT 1 and optimized ELISA 1 and ELISA 2. We evaluated a high number of IFATs, which are the most widely used tests in Ibero-America. The significant discordances observed among the tests regardless of the criteria employed hinder control programs and urge the use of a common test or with similar performances to either the optimized IFAT 1 and ELISAs 1 and 2.
Biomarkers of exposure, antibodies, and respiratory symptoms in workers heating polyurethane glue.
Skarping, G; Dalene, M; Svensson, B G; Littorin, M; Akesson, B; Welinder, H; Skerfving, S
1996-01-01
OBJECTIVES: The pathogenic basis of respiratory disorders associated with isocyanates are still obscure. One reason for this is the lack of good estimates of human exposure. In this study exposure was estimated by measurement of isocyanate metabolites in biological samples. METHODS: In a factory using isocyanate based polyurethane (PUR) glue, isocyanate concentrations in air were measured by liquid chromatography. Samples from 174 employees were analysed for metabolites of 4,4'-methylene diphenyl diisocyanate (MDI) in plasma (P-MDX) and urine (U-MDX). After hydrolysis, 4,4'-methylenedianiline was measured by gas chromatography-mass spectrometry (GC-MS). The employees were screened for work related respiratory symptoms and tested for specific immunoglobulin E (IgE) and IgG antibodies directed against isocyanate conjugated to human serum albumin. RESULTS: The time weighted isocyanate concentrations in air were low (MDI < 0.2-7; hexamethylene diisocyanate (HDI) < 0.1-0.7; 2,6-toluene diisocyanate (TDI) < 0.1 microgram/m3). All subjects had detectable P-MDX and U-MDX. There were significant associations between the estimates of exposure to thermal degradation products of an MDI based glue and P-MDX (range < or = 0.10-5.5 micrograms/l); and U-MDX (< or = 0.04-5.0 micrograms/g creatinine); in cases of heavy exposure. P-MDX and U-MDX were associated with each other (r = 0.64; P = 0.0001), work related symptoms (P-MDX: P = 0.03; Mann-Whitney U test), and serum concentrations of MDI specific IgG antibodies (r = 0.26; P = 0.0007). Unexpectedly, high P-MDX and U-MDX concentrations were also encountered in workers cutting textile (P-MDX 2.4-4.5 micrograms/l; U-MDX 0.81-3.8 micrograms/g creatinine); the reason is still unknown. Equally unexpected, there were significant negative associations between P-MDX and liver function tests. CONCLUSIONS: The results clearly show the value of biomarkers for isocyanate exposure; in particular, P-MDX is useful. Further, these results show the risk connected with thermal degradation of PUR. PMID:8704859
Zhao, Xuelian; Howell, Katie A.; He, Shihua; Brannan, Jennifer M.; Wec, Anna Z.; Davidson, Edgar; Turner, Hannah L.; Chiang, Chi-I; Lei, Lin; Fels, J. Maximilian; Vu, Hong; Shulenin, Sergey; Turonis, Ashley N.; Kuehne, Ana I.; Liu, Guodong; Ta, Mi; Wang, Yimeng; Sundling, Christopher; Xiao, Yongli; Spence, Jennifer S.; Doranz, Benjamin J.; Holtsberg, Frederick W.; Ward, Andrew B.; Chandran, Kartik; Dye, John M.; Qiu, Xiangguo; Li, Yuxing; Aman, M. Javad
2018-01-01
Summary While neutralizing antibodies are highly effective against ebolavirus infections, current experimental ebolavirus vaccines primarily elicit species-specific antibody responses. Here we describe an immunization-elicited macaque antibody (CA45) that clamps the internal fusion loop with the N-terminus of the ebolavirus glycoproteins (GP) and potently neutralizes Ebola, Sudan, Bundibugyo, and Reston viruses. CA45, alone or in combination with an antibody that blocks receptor binding, provided full protection against all pathogenic ebolaviruses in mice, guinea pigs, and ferrets. Analysis of memory B cells from the immunized macaque suggests that elicitation of broadly neutralizing antibodies (bNAbs) for ebolaviruses is possible but difficult, potentially due to the rarity of bNAb clones and their precursors. Unexpectedly, germline-reverted CA45, while exhibiting negligible binding to full-length GP, bound a proteolytically remodeled GP with picomolar affinity, suggesting that engineered ebolavirus vaccines could trigger rare bNAb precursors more robustly. These findings have important implications for developing pan-ebolavirus vaccine and immunotherapeutic cocktails. PMID:28525756
Goodpasture’s Disease: An Uncommon Disease With an Atypical Clinical Course
Shiferaw, Bethel; Miro, Viktor; Smith, Carroll; Akella, Jagadish; Chua, Walter; Kim, Zae
2016-01-01
Goodpasture’s disease is an uncommon composite of features including renal failure with pulmonary hemorrhage secondary to an autoimmune response that specifically targets these organ systems. We present a case of particular interest in regards to atypical presentation, and the uncommon treatment that the patient underwent. A 65-year-old Afghani female arrived with complaints of nausea, vomiting, loss of appetite, malaise, decreased urine output, exertional dyspnea, and cough. The patient presented initially with renal failure and unexpectedly developed respiratory failure after hemodialysis. Initial CT of thorax revealed diffuse bilateral pulmonary edema. Subsequently, the patient received a bronchoscopy demonstrating alveolar hemorrhage, which highlights a clinician’s need to maintain a differential and reassess patients. Anti-GBM antibody in the serum was detected and the renal biopsy revealed evidence of the antibody on immunofluorescence. In regards to management, the patient could only be treated with plasmapheresis as she had contraindication to initiation of immunosuppression, after which she showed significant clinical improvement. We would like to highlight the benefit of plasmapheresis without concomitant immunosuppression and recommend such an approach to be considered in similar clinical scenarios, where contraindication for immunosuppressant therapy exists. PMID:26668684
Hand, P H; Thor, A; Wunderlich, D; Muraro, R; Caruso, A; Schlom, J
1984-01-01
Monoclonal antibodies (MAbs) of predefined specificity have been generated by utilizing a synthetic peptide reflecting amino acid positions 10-17 of the Hu-rasT24 gene product as immunogen. These MAbs, designated RAP-1 through RAP-5 (RA, ras; P, peptide), have been shown to react with the ras gene product p21. Since the Hu-ras reactive determinants (positions 10-17) have been predicted to be within the tertiary structure of the p21 molecule, it was not unexpected that denaturation of cell extracts or tissue sections with Formalin or glutaraldehyde enhanced binding of the RAP MAbs. When paraffin-embedded Formalin-fixed tissue sections and the avidin-biotin complex immunoperoxidase method were used, the RAP MAbs clearly defined enhanced ras p21 expression in the majority of human colon and mammary carcinomas. The majority of all abnormal ducts and lobules from fibroadenoma and fibrocystic disease patients were negative, as were all normal mammary and colonic epithelia examined. The findings reported here form the basis for quantitative radioimmunoassays for a ras translational product and provide a means to evaluate ras p21 expression within individual cells of normal tissues and benign, "premalignant," and malignant lesions. Images PMID:6382261
Animacy, perceptual load, and inattentional blindness.
Calvillo, Dustin P; Jackson, Russell E
2014-06-01
Inattentional blindness is the failure to notice unexpected objects in a visual scene while engaging in an attention-demanding task. We examined the effects of animacy and perceptual load on inattentional blindness. Participants searched for a category exemplar under low or high perceptual load. On the last trial, the participants were exposed to an unexpected object that was either animate or inanimate. Unexpected objects were detected more frequently when they were animate rather than inanimate, and more frequently with low than with high perceptual loads. We also measured working memory capacity and found that it predicted the detection of unexpected objects, but only with high perceptual loads. The results are consistent with the animate-monitoring hypothesis, which suggests that animate objects capture attention because of the importance of the detection of animate objects in ancestral hunter-gatherer environments.
Sloan, John H; Conway, Richard G; Pottanat, Thomas G; Troutt, Jason S; Higgs, Richard E; Konrad, Robert J; Qian, Yue-Wei
2016-10-01
Immunogenicity testing of biotherapeutic drugs is a regulatory requirement. Herein, we describe a drug-tolerant assay for detecting neutralizing antibodies against a therapeutic antibody. Excess target of the therapeutic antibody was incorporated into the detection step of an affinity capture elution assay. Signal generated from binding of antidrug antibody (ADA) to the therapeutic antibody was compared with signal from binding of ADA to the therapeutic antibody preincubated with its target. The results demonstrated that the target blocked binding of the therapeutic antibody to neutralizing monkey ADA and to two anti-idiotypic antibodies. This highly drug-tolerant novel approach enables the detection of neutralizing antibodies and allows for one basic assay format to achieve complete characterization of ADA responses.
Distinct human antibody response to the biological warfare agent Burkholderia mallei.
Varga, John J; Vigil, Adam; DeShazer, David; Waag, David M; Felgner, Philip; Goldberg, Joanna B
2012-10-01
The genetic similarity between Burkholderia mallei (glanders) and Burkholderia pseudomallei (melioidosis) had led to the general assumption that pathogenesis of each bacterium would be similar. In 2000, the first human case of glanders in North America since 1945 was reported in a microbiology laboratory worker. Leveraging the availability of pre-exposure sera for this individual and employing the same well-characterized protein array platform that has been previously used to study a large cohort of melioidosis patients in southeast Asia, we describe the antibody response in a human with glanders. Analysis of 156 peptides present on the array revealed antibodies against 17 peptides with a > 2-fold increase in this infection. Unexpectedly, when the glanders data were compared with a previous data set from B. pseudomallei infections, there were only two highly increased antibodies shared between these two infections. These findings have implications in the diagnosis and treatment of B. mallei and B. pseudomallei infections.
Sharma, Vikas K.; Patapoff, Thomas W.; Kabakoff, Bruce; Pai, Satyan; Hilario, Eric; Zhang, Boyan; Li, Charlene; Borisov, Oleg; Kelley, Robert F.; Chorny, Ilya; Zhou, Joe Z.; Dill, Ken A.; Swartz, Trevor E.
2014-01-01
For mAbs to be viable therapeutics, they must be formulated to have low viscosity, be chemically stable, and have normal in vivo clearance rates. We explored these properties by observing correlations of up to 60 different antibodies of the IgG1 isotype. Unexpectedly, we observe significant correlations with simple physical properties obtainable from antibody sequences and by molecular dynamics simulations of individual antibody molecules. mAbs viscosities increase strongly with hydrophobicity and charge dipole distribution and decrease with net charge. Fast clearance correlates with high hydrophobicities of certain complementarity determining regions and with high positive or high negative net charge. Chemical degradation from tryptophan oxidation correlates with the average solvent exposure time of tryptophan residues. Aspartic acid isomerization rates can be predicted from solvent exposure and flexibility as determined by molecular dynamics simulations. These studies should aid in more rapid screening and selection of mAb candidates during early discovery. PMID:25512516
Atypical antibody responses in dengue vaccine recipients.
Kanesa-Thasan, N; Sun, W; Ludwig, G V; Rossi, C; Putnak, J R; Mangiafico, J A; Innis, B L; Edelman, R
2003-12-01
Eight of 69 (12%) healthy adult volunteers vaccinated with monovalent live-attenuated dengue virus (DENV) vaccine candidates had atypical antibody responses, with depressed IgM:IgG antibody ratios and induction of high-titer hemagglutination-inhibiting and neutralizing (NT) antibodies to all four DENV serotypes. These features suggested flavivirus exposure prior to DENV vaccination, yet no volunteer had a history of previous flavivirus infection, flavivirus vaccination, or antibody to flaviviruses evident before DENV vaccination. Moreover, production of antibody to DENV by atypical responders (AR) was not accelerated compared with antibody responses in the 61 flavivirus-naive responders (NR). Further evaluation revealed no differences in sex, age, race, DENV vaccine candidate received, or clinical signs and symptoms following vaccination between AR and NR. However, viremia was delayed at the onset in AR compared with NR. A comparative panel of all AR and five randomly selected NR found flavivirus cross-reactive antibody after vaccination only in AR. Unexpectedly, six of eight AR had NT antibodies to yellow fever virus (YFV) > 1:10 before vaccination while NR had none (P = 0.04). The AR also universally demonstrated YFV NT antibody titers > or = 1:160 after DENV vaccination, whereas four of five NR failed to seroconvert (P = 0.02). Yellow fever virus priming broadens the antibody response to monovalent DENV vaccination. The effect of flavivirus priming on the clinical and immunologic response to tetravalent DENV vaccine remains to be determined.
Osuna, Christa E; Grandjean, Philippe; Weihe, Pál; El-Fawal, Hassan A N
2014-11-01
Methylmercury, polychlorinated biphenyls (PCBs), and perfluorinated compounds (PFCs) are ubiquitous and persistent environmental chemicals with known or suspected toxic effects on the nervous system and the immune system. Animal studies have shown that tissue damage can elicit production of autoantibodies. However, it is not known if autoantibodies similarly will be generated and detectable in humans following toxicant exposures. Therefore, we conducted a pilot study to investigate if autoantibodies specific for neural and non-neural antigens could be detected in children at age 7 years who have been exposed to environmental chemicals. Both prenatal and age-7 exposures to mercury, PCBs, and PFCs were measured in 38 children in the Faroe Islands who were exposed to widely different levels of these chemicals due to their seafood-based diet. Concentrations of IgM and IgG autoantibodies specific to both neural (neurofilaments, cholineacetyltransferase, astrocyte glial fibrillary acidic protein, and myelin basic protein) and non-neural (actin, desmin, and keratin) antigens were measured and the associations of these autoantibody concentrations with chemical exposures were assessed using linear regression. Age-7 blood-mercury concentrations were positively associated with titers of multiple neural- and non-neural-specific antibodies, mostly of the IgM isotype. Additionally, prenatal blood-mercury and -PCBs were negatively associated with anti-keratin IgG and prenatal PFOS was negatively associated with anti-actin IgG. These exploratory findings demonstrate that autoantibodies can be detected in the peripheral blood following exposure to environmental chemicals. The unexpected association of exposures with antibodies specific for non-neural antigens suggests that these chemicals may have toxicities that have not yet been recognized. © The Author 2014. Published by Oxford University Press on behalf of the Society of Toxicology. All rights reserved. For permissions, please email: journals.permissions@oup.com.
2012-01-01
Background Viral myocarditis is a major cause of sudden unexpected death in children and young adults. Until recently, coxsackievirus B3 (CVB3) has been the most commonly implicated virus in myocarditis. At present, no standard diagnosis is generally accepted due to the insensitivity of traditional diagnostic tests. This has prompted health professionals to seek new diagnostic approaches, which resulted in the emergence of new molecular pathological tests and a more detailed immunohistochemical and histopathological analysis. When supplemented with immunohistochemistry and molecular pathology, conventional histopathology may provide important clues regarding myocarditis underlying etiology. Methods This study is based on post-mortem samples from sudden unexpected death victims and controls who were investigated prospectively. Immunohistochemical investigations for the detection of the enteroviral capsid protein VP1 and the characterization and quantification of myocardial inflammatory reactions as well as molecular pathological methods for enteroviral genome detection were performed. Results Overall, 48 sudden unexpected death victims were enrolled. As for controls, 37 cases of unnatural traffic accident victims were studied. Enterovirus was detected in 6 sudden unexpected death cases (12.5 %). The control samples were completely enterovirus negative. Furthermore, the enteroviral capsid protein VP1 in the myocardium was detected in enterovirus-positive cases revealed by means of reverse transcriptase-polymerase chain reaction (RT-PCR). Unlike control samples, immunohistochemical investigations showed a significant presence of T and B lymphocytes in sudden unexpected death victims. Conclusions Our findings demonstrate clearly a higher prevalence of viral myocarditis in cases of sudden unexpected death compared to control subjects, suggesting that coxsackie B enterovirus may contribute to myocarditis pathogenesis significantly. PMID:22966951
Louie, Brian; Lei, John; Liska, Sally; Dowling, Teri; Pandori, Mark W
2009-07-01
The performances of three blood-based immunoassays test kits were compared with regard to their ability to detect HIV-1 antibody in oral fluid. It was found that these three kits differ in their ability to detect HIV-1 antibody. Notably, a third generation EIA which has been shown to possess superior sensitivity for antibody detection in plasma appears to possess no sensitivity advantage for detecting HIV-1 antibody in oral fluid.
Lo, Chia-Yun; Strobl, Susan L.; Dunham, Kimberly; Wang, Wei; Stewart, Lucy; Misplon, Julia A.; Garcia, Mayra; Gao, Jin; Ozawa, Tatsuhiko; Price, Graeme E.; Navidad, Jose; Gradus, Steve; Bhattacharyya, Sanjib; Viboud, Cecile; Eichelberger, Maryna C.; Weiss, Carol D.; Gorski, Jack
2017-01-01
Abstract Background. Antibody and T-cell immunity to conserved influenza virus antigens can protect animals against infection with diverse influenza strains. Although immunity against conserved antigens occurs in humans, whether such responses provide cross-protection in humans and could be harnessed as the basis for universal influenza vaccines is controversial. The 2009 pandemic provided an opportunity to investigate whether pre-existing cross-reactive immunity affected susceptibility to infection. Methods. In 2009, we banked sera and peripheral blood mononuclear cells (PBMC) from blood donors, then monitored them for pandemic influenza infection (pH1N1) by polymerase chain reaction or seroconversion. Antibodies to hemagglutinin (HA), neuraminidase (NA), nucleoprotein (NP), matrix 2 (M2), and HA-pseudotypes were measured in sera. T-cell inteferon-γ enzyme-linked immunospot responses were measured in PBMC. Results. There were 13 infections in 117 evaluable donors. Pre-existing T-cell reactivity to pH1N1 was substantial (of 153 donors tested, 146 had >100 spot-forming cells/106 cells). Antibodies reactive with pH1N1 were common: anti-NP (all donors) and anti-M2 (44% of donors). Pseudotype-neutralizing antibodies to H1 were detected, but not to highly conserved HA epitopes. Unexpectedly, donors with symptomatic pH1N1 infection had sharp rises in HA pseudotype-neutralizing antibodies, not only pH1N1 but also against multiple seasonal H1s. In addition, an exploratory study of a T-cell marker (response to NP418-426) identified probable infection missed by standard criteria. Conclusions. Although the number of infections was inadequate for conclusions about mechanisms of protection, this study documents the wide variety of pre-existing, cross-reactive, humoral and cellular immune responses to pandemic influenza virus antigens in humans. These responses can be compared with results of other studies and explored in universal influenza vaccine studies. PMID:28730155
Clinical survey of antibodies against red blood cells in horses after homologous blood transfusion.
Wong, P L; Nickel, L S; Bowling, A T; Steffey, E P
1986-12-01
Serum samples of 20 horses were evaluated for antibodies against RBC after homologous blood transfusion. Transfusion-associated antibodies against RBC were detected in 10 horses. Antibodies recognizing horse blood group antigens Aa, Ae, Db, and Dc were identified. Antibodies against Aa were found in all samples from Aa-negative horses that were transfused with Aa-positive RBC. Antibodies against Aa persisted for at least 1 year after transfusion. Antibodies against Ae were detected in 7 of 8 horses transfused with Ae-positive RBC. Initial appearance and persistence of antibodies against Ae differed among the horses; antibodies were initially detected 1 week to 154 weeks after transfusion and disappeared as early as 4 weeks after transfusion. Antibodies against Db or Dc were detected in less than or equal to 33% of the horses that lacked Db or Dc antigens and were transfused with Db- or Dc-positive RBC. Antibodies against Db and Dc were initially detected in sera later than were the A-system antibodies. Three mares with transfusion-associated antibodies subsequently produced healthy offspring. Two foals had RBC antigens corresponding to their dam's alloantibodies; maternal colostrum with antibodies against Aa was withheld from the Aa-positive foal. The Db-positive foal remained healthy after nursing the mare with serum antibodies against Db.
[Antibody responses in Japanese volunteers after immunization with yellow fever vaccine].
Taga, Kenichiro; Imura, Shunro; Hayashi, Akihiro; Kamakura, Kazumasa; Hashimoto, Satoru; Takasaki, Tomohiko; Kurane, Ichiro; Uchida, Yukinori
2002-09-01
To monitor the development of specific and cross-reactive antibody response in twenty Japanese volunteers after vaccination with live yellow fever vaccine. Serum samples were collected on various days after vaccination and examined for hemagglutination inhibition (HI) antibodies against yellow fever virus (YFV), Japanese encephalitis virus (JEV) and dengue virus (DV), neutralizing antibodies against YFV and JEV, and IgM antibodies against YFV. None of the volunteers had been previously immunized with this vaccine. Fifteen of 20 had pre-vaccinated with JEV 7 to 40 years before. Ten of the 20 had neutralizing antibodies against JEV before immunization. None of the 20 had detectable antibodies against YFV or DV before vaccination. On day 10th after the vaccination, neutralizing antibodies to YFV were detected in 6 of 19 volunteers and IgM antibodies against YFV were detected in 7 of 19. On day 14th, HI, neutralizing, and IgM antibodies against YFV were detected in all the tested sera. Neutralizing antibodies against JEV were developed in 2 volunteers and HI antibodies against JEV were increased in 3 of 6 volunteers respectively. On day 29th, cross-reactive HI antibodies for JEV and DV were detected in all the tested sera. The results indicate that YF vaccine induces YFV-specific antibodies in all the tested volunteers and that it also induces HI antibodies cross-reactive for JEV and DV. The YF vaccine has a strong immunogenicity because it is a live vaccine, and induces antibody against YFV predominantly. The international certificate of yellow fever vaccination becomes valid 10 days after vaccination. On day 14th after vaccination, we detected neutralizing antibodies against YFV from all tested volunteers, however, only 6 of 19 volunteers had detectable neutralizing antibody on the 10th day after vaccination. Therefore, the vaccine may not be perfectly effective on day 10th after the vaccination.
Novo, Pedro; Prazeres, Duarte Miguel França; Chu, Virginia; Conde, João Pedro
2011-12-07
Microfluidic technology has the potential to decrease the time of analysis and the quantity of sample and reactants required in immunoassays, together with the potential of achieving high sensitivity, multiplexing, and portability. A lab-on-a-chip system was developed and optimized using optical and fluorescence microscopy. Primary antibodies are adsorbed onto the walls of a PDMS-based microchannel via microspotting. This probe antibody is then recognised using secondary FITC or HRP labelled antibodies responsible for providing fluorescence or chemiluminescent and colorimetric signals, respectively. The system incorporated a micron-sized thin-film hydrogenated amorphous silicon photodiode microfabricated on a glass substrate. The primary antibody spots in the PDMS-based microfluidic were precisely aligned with the photodiodes for the direct detection of the antibody-antigen molecular recognition reactions using chemiluminescence and colorimetry. The immunoassay takes ~30 min from assay to the integrated detection. The conditions for probe antibody microspotting and for the flow-through ELISA analysis in the microfluidic format with integrated detection were defined using antibody solutions with concentrations in the nM-μM range. Sequential colorimetric or chemiluminescence detection of specific antibody-antigen molecular recognition was quantitatively detected using the photodiode. Primary antibody surface densities down to 0.182 pmol cm(-2) were detected. Multiplex detection using different microspotted primary antibodies was demonstrated.
DETECTION OF IDIOTYPIC CROSS-REACTIONS AMONG STREPTOCOCCAL ANTISERA FROM RELATED RABBITS
Kindt, Thomas J.; Seide, Rochelle K.; Bokisch, Viktor A.; Krause, Richard M.
1973-01-01
Idiotypic cross-reactions among antibodies to Group C streptococcal carbohydrate were studied using idiotypic antisera prepared in allotypically matched rabbits. Antibodies with idiotypic cross-specificity to one proband antibody were detected in 58% of the antisera from related rabbits, while approximately 1% of nonrelated rabbits produced antibody with this specificity. The cross-specificity was related to the group a (VH) allotype of 133 rabbits tested with only one exception. Studies utilizing antisera against a second proband antibody failed to detect antibodies with idiotypic cross-reactivity among the same group of related rabbits. This result emphasizes the variation in expression of idiotypic determinants of antibodies. It was further shown that the presence of anti-IgG's in the streptococcal antisera interfere with the detection of idiotypic cross-reactions. These anti-IgG's masked the presence of antibodies with idiotypic cross-specificity when inhibition of precipitation tests were used for their detection. PMID:4727913
Liu, Xi; Yang, Zheng; Yuan, Jing; Liao, Jian; Duan, Lian; Wang, Wenfei; Zhang, Fuping; Chen, Xinchun; Zhou, Boping
2017-09-01
A new type of highly pathogenic avian influenza virus, H7N9, has been a great threat to public health since its 2013 outbreak. The humoral immune response plays a critical role in protection from the influenza virus, but its role and kinetics in H7N9-infected patients remain to be determined. In this study, we performed a retrospective investigation of the antibody response in plasma samples from 37 cases of hospitalized patients and analysed the relationship between the antibody response and the clinical outcomes. Our results showed that the HA7-binding antibody was generated earlier than the neutralizing antibody. Higher titer of HA7-binding antibody during the first 14 days after disease onset were associated with a shorter virus-positive continuation period, which is an important risk predictor ( P <0.05). Additionally, the titers of HA7-binding antibody were consistently and significantly lower in patients who died than those who recovered from the severe disease. Unexpectedly, no correlation between the titer of neutralizing antibody and the resulting clinical outcomes was found, suggesting that a neutralizing antibody-independent mechanism also contributed to virus control. In summary, our data suggests that an early antibody response against H7N9 influenza virus contributes to the eradication of the virus. A higher, early HA7-binding antibody response is associated with better clinical outcomes in H7N9 patients. © 2017 by the Association of Clinical Scientists, Inc.
Frade, Marco Andrey C; de Paula, Natália A; Gomes, Ciro M; Vernal, Sebastian; Bernardes Filho, Fred; Lugão, Helena B; de Abreu, Marilda M M; Botini, Patrícia; Duthie, Malcolm S; Spencer, John S; Soares, Rosa Castália F R; Foss, Norma T
2017-02-01
Leprosy diagnosis is mainly based on clinical evaluation, although this approach is difficult, especially for untrained physicians. We conducted a temporary campaign to detect previously unknown leprosy cases in midwestern Brazil and to compare the performance of different serological tests. A mobile clinic was stationed at the main bus terminal in Brasília, Brazil. Volunteers were quizzed and given a clinical exam to allow categorization as either patients, known contacts of patients or non-contacts, and blood was collected to determine anti-PGL-I and anti-LID-1 antibody titers by ELISA and by the NDO-LID rapid test. New cases of leprosy and the impact of performing this broad random surveillance strategy were evaluated. Accuracy values and concordance between the test results were evaluated among all groups. Four hundred thirty-four individuals were evaluated, and 44 (10.1%) were diagnosed with leprosy. Borderline forms were the most frequent presentation. Both tests presented higher positivity in those individuals with multibacillary disease. Serological tests demonstrated specificities arround 70% for anti-PGL-1 and anti-LID ELISA; and arround 40% for NDO-LID. Sensitivities ranged from 48 to 62%. A substantial agreement between NDO-LID and ELISA with concomitant positive results was found within leprosy patients (Kappa index = 0.79 CI95% 0.36-1.22). The unexpectedly high leprosy prevalence in this population indicates ongoing community-based exposure to Mycobacterium leprae antigens and high rates of subclinical infection. All tests showed low specificity and sensitivity values and therefore cannot be considered for use as stand-alone diagnostics. Rather, considering their positivity among MB patients and non-patients, these tests can be considered effective tools for screening and identifying individuals at high risk who might benefit from regular monitoring.
Zhang, Yu; Liu, Huiying; Sun, Bin; Zhao, Linlin; Ge, Naijian; Qian, Haihua; Yang, Yefa; Wu, Mengchao; Yin, Zhengfeng
2014-01-01
Background Asialoglycoprotein receptor (ASGPR)-ligand-based separation combined with identification with Hep Par 1 or pan-cytokeratin (P-CK) antibody have been demonstrated to detect circulating tumor cells (CTCs) in hepatocellular carcinoma (HCC). The aim of this study was to develop an improved enrichment and identification system that allows the detection of all types of HCC CTCs. Methods The specificity of the prepared anti-ASGPR monoclonal antibody was characterized. HCC cells were bound by ASGPR antibody and subsequently magnetically isolated by second antibody-coated magnetic beads. Isolated HCC cells were identified by immunofluorescence staining using a combination of anti-P-CK and anti-carbamoyl phosphate synthetase 1 (CPS1) antibodies. Blood samples spiked with HepG2 cells were used to determine recovery and sensitivity. CTCs were detected in blood samples from HCC patients and other patients. Results ASGPR was exclusively expressed in human hepatoma cell line, normal hepatocytes and HCC cells in tissue specimens detected by the ASGPR antibody staining. More HCC cells could be identified by the antibody cocktail for CPS1 and P-CK compared with a single antibody. The current approach obtained a higher recovery rate of HepG2 cells and more CTC detection from HCC patients than the previous method. Using the current method CTCs were detected in 89% of HCC patients and no CTCs were found in the other test subjects. Conclusions Our anti-ASGPR antibody could be used for specific and efficient HCC CTC enrichment, and anti-P-CK combined with anti-CPS1 antibodies is superior to identification with one antibody alone in the sensitivity for HCC CTC detection. PMID:24763545
Development and application of antibody microarray for lymphocystis disease virus detection in fish.
Sheng, Xiuzhen; Xu, Xiaoli; Zhan, Wenbin
2013-05-01
Lymphocystis disease virus (LCDV) is the causative agent of lymphocystis disease affecting marine and freshwater fish worldwide. Here an antibody microarray was developed and employed to detect LCDV in fish. Rabbit anti-LCDV serum was arrayed on agarose gel-modified slides as capture antibody, and Cy3-conjugated anti-LCDV monoclonal antibody (MAbs) was added as detection antibody. The signals were imaged with a laser chip scanner and analyzed by corresponding software. To improve the sensitivity, different substrate binders (poly-L-lysine, MPTS, aldehyde, APES and agarose gel modified slides, and commercially available amino-modified slides), markers (fluorescein isothiocyanate, Cy3, horseradish peroxidase, biotin or colloidal gold) conjugated to anti-LCDV Mabs, and storage time of the antibody were assessed. The results showed that the antibody microarrays based on agarose gel-modified slides gave a lower detection limit of 0.55μg/ml of LCDV when Cy3 and HRP conjugated anti-LCDV MAbs were used as detection antibody; and the lowest detectable LCDV protein concentration was 0.0686 μg/ml when streptavidin-biotin conjugated to anti-LCDV MAbs served as detection antibody. The developed antibody microarray proved to have a high specificity for LCDV detection and a shelf-life of more than 8 months at -20°C. Furthermore, the LCDV detection results of the microarray in fish gills or fins (n=50) presented a concordance rate of 100% with enzyme-linked immunosorbent assay (ELISA) and 98% with immunofluorescence assay technique (IFAT). These results revealed that the developed antibody microarray could serve as an effective tool for diagnostic and epidemiological studies of LCDV in fish. Copyright © 2013 Elsevier B.V. All rights reserved.
A model of high-affinity antibody binding to type III group B Streptococcus capsular polysaccharide.
Wessels, M R; Muñoz, A; Kasper, D L
1987-12-01
We recently reported that the single repeating-unit pentasaccharide of type III group B Streptococcus (GBS) capsular polysaccharide is only weakly reactive with type III GBS antiserum. To further elucidate the relationship between antigen-chain length and antigenicity, tritiated oligosaccharides derived from type III capsular polysaccharide were used to generate detailed saturation binding curves with a fixed concentration of rabbit antiserum in a radioactive antigen-binding assay. A graded increase in affinity of antigen-antibody binding was seen as oligosaccharide size increased from 2.6 repeating units to 92 repeating units. These differences in affinity of antibody binding to oligosaccharides of different molecular size were confirmed by immunoprecipitation and competitive ELISA, two independent assays of antigen-antibody binding. Analysis of the saturation binding experiment indicated a difference of 300-fold in antibody-binding affinity for the largest versus the smallest tested oligosaccharides. Unexpectedly, the saturation binding values approached by the individual curves were inversely related to oligosaccharide chain length on a molar basis but equivalent on a weight basis. This observation is compatible with a model in which binding of an immunoglobulin molecule to an antigenic site on the polysaccharide facilitates subsequent binding of antibody to that antigen.
Kuglstatter, A; Stihle, M; Neumann, C; Müller, C; Schaefer, W; Klein, C; Benz, J
2017-09-01
An increasing number of bispecific therapeutic antibodies are progressing through clinical development. The Knob-into-Hole (KiH) technology uses complementary mutations in the CH3 region of the antibody Fc fragment to achieve heavy chain heterodimerization. Here we describe the X-ray crystal structures of glycosylated and disulfide-engineered heterodimeric KiH Fc fragment and its homodimeric Knob-Knob and Hole-Hole side products. The heterodimer structure confirms the KiH design principle and supports the hypothesis that glycosylation stabilizes a closed Fc conformation. Both homodimer structures show parallel Fc fragment architectures, in contrast to recently reported crystal structures of the corresponding aglycosylated Fc fragments which in the absence of disulfide mutations show an unexpected antiparallel arrangement. The glycosylated Knob-Knob Fc fragment is destabilized as indicated by variability in the relative orientation of its CH3 domains. The glycosylated Hole-Hole Fc fragment shows an unexpected intermolecular disulfide bond via the introduced Y349C Hole mutation which results in a large CH3 domain shift and a new CH3-CH3 interface. The crystal structures of glycosylated, disulfide-linked KiH Fc fragment and its Knob-Knob and Hole-Hole side products reported here will facilitate further design of highly efficient antibody heterodimerization strategies. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Watanabe, Osamu
2013-04-01
Various antibodies are associated with voltage-gated potassium channels (VGKCs). Representative antibodies to VGKCs were first identified by radioimmunoassays using radioisotope-labeled alpha-dendrotoxin-VGKCs solubilized from rabbit brain. These antibodies were detected only in a proportion of patients with acquired neuromyotonia (Isaacs' syndrome). VGKC antibodies were also detected in patients with Morvan's syndrome and in those with a form of autoimmune limbic encephalitis. Recent studies indicated that the "VGKC" antibodies are mainly directed toward associated proteins (for example LGI-1 and CASPR-2) that complex with the VGKCs themselves. The "VGKC" antibodies are now commonly known as VGKC-complex antibodies. In general, LGI-1 antibodies are most commonly detected in patients with limbic encephalitis with syndrome of inappropriate secretion of antidiuretic hormone. CASPR-2 antibodies are present in the majority of patients with Morvan's syndrome. These patients develop combinations of CNS symptoms, autonomic dysfunction, and peripheral nerve hyperexcitability. Furthermore, VGKC-complex antibodies are tightly associated with chronic idiopathic pain. Hyperexcitability of nociceptive pathways has also been implicated. These antibodies may be detected in sera of some patients with neurodegenerative diseases (for example, amyotrophic lateral sclerosis and Creutzfeldt-Jakob disease).
Milongo, D; Kamar, N; Del Bello, A; Guilbeau-Frugier, C; Sallusto, F; Esposito, L; Dörr, G; Blancher, A; Congy-Jolivet, N
2017-02-01
The reasons for the increased incidence of de novo anti-human leukocyte antibody (HLA) donor-specific antibodies (DSAs) observed after kidney allograft nephrectomy are not fully understood. One advocated mechanism suggests that at graft loss, DSAs are not detected in the serum because they are fixed on the nonfunctional transplant; removal of the kidney allows DSAs to then appear in the blood circulation. The aim of our study was to compare anti-HLA antibodies present in the serum and in the graft at the time of an allograft nephrectomy. Using solid-phase assays, anti-HLA antibodies were searched for in the sera of 17 kidney transplant patients undergoing allograft nephrectomy. No anti-HLA antibodies were detected in the graft if they were not also detected in the serum. Eleven of the 12 patients who had DSAs detected in their sera also had DSAs detected in the grafts. Epitopic analysis revealed that most anti-HLA antibodies detected in removed grafts were directed against the donor. In summary, our data show that all anti-HLA antibodies that were detected in grafts were also detected in the sera. These intragraft anti-HLA antibodies are mostly directed against the donor at an epitopic level but not always at an antigenic level. © Copyright 2016 The American Society of Transplantation and the American Society of Transplant Surgeons.
Improving TCO-Conjugated Antibody Reactivity for Bioorthogonal Pretargeting
NASA Astrophysics Data System (ADS)
Chu, Tina Tingyi
Cancer remains a major cause of death because of its unpredictable progression. Utilizing bioorthogonal chemistry between trans-cyclooctene (TCO) and tetrazine to target imaging agents to tumors in two subsequent steps offers a more versatile platform for molecular imaging. This is accomplished by pretargeting TCO-modified primary antibody to cell surface biomarkers, followed by delivery of tetrazine-modified imaging probes. In previous work, it has been established that TCO-tetrazine chemistry can be applied to in vivo imaging, resulting in precise tumor detection. However, most TCO modifications on an antibody are not reactive because they are buried within hydrophobic domains. To expose and improve the reactivity, Rahim et al. incorporated a polyethylene glycol (PEG) linker through a two-step reaction with DBCO-azide, which successfully maintained 100% TCO functionality. In this project, various types of linkers were studied to improve the reactivity in a single step. Three primary types of linkers were studied: hydrophilic PEG chains, hydrophobic short linkers, and amphiphilic linkers. Our results show that PEG chain alone can only maintain 40% TCO reactivity. Unexpectedly, a short alkyl chain (valeric acid) provided superior results, with 60% TCO reactivity. Lengthening the alkyl chain did not improve results further. Finally, an amphiphilic linker containing valeric acid and PEG performed worse than either linker type alone, at ˜30% functionality. We conclude that our previous 100% functional TCO result obtained with the two-step coupling may have stemmed from generation of the DBCO/azide cycloaddition product. Future work will explore factors such as rigidity of linker structure, polarity, or charges.
Nagata, Keiko; Higaki, Katsumi; Nakayama, Yuji; Miyauchi, Hiromi; Kiritani, Yui; Kanai, Kyosuke; Matsushita, Michiko; Iwasaki, Takeshi; Sugihara, Hirotsugu; Kuwamoto, Satoshi; Kato, Masako; Murakami, Ichiro; Nanba, Eiji; Kimura, Hiroshi; Hayashi, Kazuhiko
2014-05-01
Graves' disease is an autoimmune hyperthyroidism caused by thyrotropin receptor antibodies (TRAbs). Because Epstein-Barr virus (EBV) persists in B cells and is occasionally reactivated, we hypothesized that EBV contributes to TRAbs production in Graves' disease patients by stimulating the TRAbs-producing B cells. In order for EBV to stimulate antibody-producing cells, EBV must be present in those cells but that have not yet been observed. We examined whether EBV-infected (EBV(+)) B cells with TRAbs on their surface (TRAbs(+)) as membrane immunoglobulin were present in peripheral blood of Graves' disease patients. We analyzed cultured or non-cultured peripheral blood mononuclear cells (PBMCs) from 13 patients and 11 healthy controls by flow-cytometry and confocal laser microscopy, and confirmed all cultured PBMCs from 8 patients really had TRAbs(+) EBV(+) double positive cells. We unexpectedly detected TRAbs(+) cells in all healthy controls, and TRAbs(+) EBV(+) double positive cells in all cultured PBMC from eight healthy controls. The frequency of TRAbs(+) cells in cultured PBMCs was significantly higher in patients than in controls (p = 0.021). In this study, we indicated the presence of EBV-infected B lymphocytes with TRAbs on their surface, a possible player of the production of excessive TRAbs, the causative autoantibody for Graves' disease. This is a basic evidence for our hypothesis that EBV contributes to TRAbs production in Graves' disease patients. Our results further suggest that healthy controls have the potential for TRAbs production. This gives us an important insight into the pathogenesis of Graves' disease.
Nagata, Keiko; Higaki, Katsumi; Nakayama, Yuji; Miyauchi, Hiromi; Kiritani, Yui; Kanai, Kyosuke; Matsushita, Michiko; Iwasaki, Takeshi; Sugihara, Hirotsugu; Kuwamoto, Satoshi; Kato, Masako; Murakami, Ichiro; Nanba, Eiji; Kimura, Hiroshi; Hayashi, Kazuhiko
2014-01-01
Abstract Graves’ disease is an autoimmune hyperthyroidism caused by thyrotropin receptor antibodies (TRAbs). Because Epstein–Barr virus (EBV) persists in B cells and is occasionally reactivated, we hypothesized that EBV contributes to TRAbs production in Graves’ disease patients by stimulating the TRAbs-producing B cells. In order for EBV to stimulate antibody-producing cells, EBV must be present in those cells but that have not yet been observed. We examined whether EBV-infected (EBV(+)) B cells with TRAbs on their surface (TRAbs(+)) as membrane immunoglobulin were present in peripheral blood of Graves’ disease patients. We analyzed cultured or non-cultured peripheral blood mononuclear cells (PBMCs) from 13 patients and 11 healthy controls by flow-cytometry and confocal laser microscopy, and confirmed all cultured PBMCs from 8 patients really had TRAbs(+) EBV(+) double positive cells. We unexpectedly detected TRAbs(+) cells in all healthy controls, and TRAbs(+) EBV(+) double positive cells in all cultured PBMC from eight healthy controls. The frequency of TRAbs(+) cells in cultured PBMCs was significantly higher in patients than in controls (p = 0.021). In this study, we indicated the presence of EBV-infected B lymphocytes with TRAbs on their surface, a possible player of the production of excessive TRAbs, the causative autoantibody for Graves’ disease. This is a basic evidence for our hypothesis that EBV contributes to TRAbs production in Graves’ disease patients. Our results further suggest that healthy controls have the potential for TRAbs production. This gives us an important insight into the pathogenesis of Graves’ disease. PMID:24467196
Influenza A virus hemagglutinin glycosylation compensates for antibody escape fitness costs.
Kosik, Ivan; Ince, William L; Gentles, Lauren E; Oler, Andrew J; Kosikova, Martina; Angel, Matthew; Magadán, Javier G; Xie, Hang; Brooke, Christopher B; Yewdell, Jonathan W
2018-01-01
Rapid antigenic evolution enables the persistence of seasonal influenza A and B viruses in human populations despite widespread herd immunity. Understanding viral mechanisms that enable antigenic evolution is critical for designing durable vaccines and therapeutics. Here, we utilize the primerID method of error-correcting viral population sequencing to reveal an unexpected role for hemagglutinin (HA) glycosylation in compensating for fitness defects resulting from escape from anti-HA neutralizing antibodies. Antibody-free propagation following antigenic escape rapidly selected viruses with mutations that modulated receptor binding avidity through the addition of N-linked glycans to the HA globular domain. These findings expand our understanding of the viral mechanisms that maintain fitness during antigenic evolution to include glycan addition, and highlight the immense power of high-definition virus population sequencing to reveal novel viral adaptive mechanisms.
ANTIDOG IgG SECONDARY ANTIBODY SUCCESSFULLY DETECTS IgG IN A VARIETY OF AQUATIC MAMMALS.
Roehl, Katherine; Jankowski, Mark; Hofmeister, Erik
2016-12-01
Serological tests play an important role in the detection of wildlife diseases. However, while there are many commercial assays and reagents available for domestic species, there is a need to develop efficient serological assays for wildlife. In recent years, marine mammals have represented a wildlife group with emerging infectious diseases, such as influenza, brucellosis, and leptospirosis. However, with the exception of disease-agent-specific assays or functional assays, few reports describe the use of antibody detection assays in marine mammals. In an indirect enzyme-linked immunoassay (EIA) or an immunofluorescence assay, antibody is detected using an antitarget species secondary conjugated antibody. The sensitivity of the assay depends on the avidity of the binding reaction between the bound antibody and the detection antibody. A commercial polyclonal antidog IgG conjugated antibody was tested in an EIA for its ability to sensitively detect the IgG of seven marine mammals including sea otter ( Enhydra lutris ), polar bear ( Ursus maritimus ), grey seal ( Halichoerus grypus ), harbor seal ( Phoca vitulina ), northern elephant seal ( Mirounga angustirostris ), California sea lion ( Zalophus californianus ), Pacific walrus ( Odobenus rosmarus ) and one freshwater mammal: Asian small-clawed otter ( Aonyx cinerea ). With the exception of Asian small-clawed sea otters, the detection of IgG in these marine mammals either exceeded or was nearly equal to detection of dog IgG. The use of the tested commercial antidog IgG antibody may be a valid approach to the detection of antibody response to disease in sea mammals.
Anti-dog IgG secondary antibody successfully detects IgG in a variety of aquatic mammals
Roehl, Katherine; Jankowski, Mark D.; Hofmeister, Erik K.
2016-01-01
Serological tests play an important role in the detection of wildlife diseases. However, while there are many commercial assays and reagents available for domestic species, there is a need to develop efficient serological assays for wildlife. In recent years, marine mammals have represented a wildlife group with emerging infectious diseases, such as influenza, brucellosis, and leptospirosis. However, with the exception of disease-agent-specific assays or functional assays, few reports describe the use of antibody detection assays in marine mammals. In an indirect enzyme-linked immunoassay (EIA) or an immunofluorescence assay, antibody is detected using an antitarget species secondary conjugated antibody. The sensitivity of the assay depends on the avidity of the binding reaction between the bound antibody and the detection antibody. A commercial polyclonal antidog IgG conjugated antibody was tested in an EIA for its ability to sensitively detect the IgG of seven marine mammals including sea otter (Enhydra lutris), polar bear (Ursus maritimus), grey seal (Halichoerus grypus), harbor seal (Phoca vitulina), northern elephant seal (Mirounga angustirostris), California sea lion (Zalophus californianus), Pacific walrus (Odobenus rosmarus) and one freshwater mammal: Asian small-clawed otter (Aonyx cinerea). With the exception of Asian small-clawed sea otters, the detection of IgG in these marine mammals either exceeded or was nearly equal to detection of dog IgG. The use of the tested commercial antidog IgG antibody may be a valid approach to the detection of antibody response to disease in sea mammals.
Surface grafted antibodies: controlled architecture permits enhanced antigen detection.
Sebra, Robert P; Masters, Kristyn S; Bowman, Christopher N; Anseth, Kristi S
2005-11-22
The attachment of antibodies to substrate surfaces is useful for achieving specific detection of antigens and toxins associated with clinical and field diagnostics. Here, acrylated whole antibodies were produced through conjugation chemistry, with the goal of covalently photografting these proteins from surfaces in a controlled fashion, to facilitate rapid and sensitive antigenic detection. A living radical photopolymerization chemistry was used to graft the acrylated whole antibodies on polymer surfaces at controlled densities and spatial locations by controlling the exposure time and area, respectively. Copolymer grafts containing these antibodies were synthesized to demonstrate two principles. First, PEG functionalities were introduced to prevent nonspecific protein interactions and improve the reaction kinetics by increasing solvation and mobility of the antibody-containing chains. Both of these properties lead to sensitive (pM) and rapid (<20 min) detection of antigens with this surface modification technique. Second, graft composition was tailored to include multiple antibodies on the same grafted chains, establishing a means for simultaneously detecting multiple antigens on one grafted surface area. Finally, the addition of PEG spacers between the acrylate functionality and the pendant detection antibodies was tuned to enhance the detection of a short-half-life molecule, glucagon, in a complex biological environment, plasma.
Distinct human antibody response to the biological warfare agent Burkholderia mallei
Varga, John J.; Vigil, Adam; DeShazer, David; Waag, David M.; Felgner, Philip; Goldberg, Joanna B.
2012-01-01
The genetic similarity between Burkholderia mallei (glanders) and Burkholderia pseudomallei (melioidosis) had led to the general assumption that pathogenesis of each bacterium would be similar. In 2000, the first human case of glanders in North America since 1945 was reported in a microbiology laboratory worker. Leveraging the availability of pre-exposure sera for this individual and employing the same well-characterized protein array platform that has been previously used to study a large cohort of melioidosis patients in southeast Asia, we describe the antibody response in a human with glanders. Analysis of 156 peptides present on the array revealed antibodies against 17 peptides with a > 2-fold increase in this infection. Unexpectedly, when the glanders data were compared with a previous data set from B. pseudomallei infections, there were only two highly increased antibodies shared between these two infections. These findings have implications in the diagnosis and treatment of B. mallei and B. pseudomallei infections. PMID:23076276
James, Kaitlyn E; Smith, Woutrina A; Conrad, Patricia A; Packham, Andrea E; Guerrero, Leopoldo; Ng, Mitchell; Pusterla, Nicola
2017-06-01
OBJECTIVE To describe the general seroprevalence of anti-Sarcocystis neurona and anti-Neospora hughesi antibodies among healthy equids by use of indirect fluorescent antibody tests and determine potential risk factors for seropositivity. DESIGN Cross-sectional study. SAMPLE Whole blood samples collected from 5,250 equids (1 sample/animal) across 18 states in the United States during October 2013. PROCEDURES Information regarding potential risk factors (geographic region, breed, primary use, sex, and age) was collected along with the blood samples. For each equid, an indirect fluorescent antibody test was used to determine serum titers of antibody against each of the 2 protozoal parasites. Mixed-effects logistic regression models were created to determine ORs for seropositivity. RESULTS The overall seroprevalence of anti-S neurona and anti-N hughesi antibodies in the tested equids was 78% and 34%, respectively. Of the equids, 31% were seropositive and 18% were seronegative for antibodies against both parasites. Factors associated with equids being seropositive for anti-S neurona antibodies were residence in the South, warmblood breed, and age > 5 years. Seroprevalence of anti-N hughesi antibodies did not differ among equids in different states across the country, but warmblood breed and age > 5 years were associated with seropositivity. CONCLUSIONS AND CLINICAL RELEVANCE With regard to risk factors for S neurona and N hughesi exposure and antibody response among tested equids, older age was not unexpected; however, the influences of warmblood breed and geographic location on seropositivity for anti-S neurona antibody but not for anti-N hughesi antibody deserve further investigation.
Zhou, Jie; Liao, Yu-xue; Chen, Zhong; Li, Yu-chun; Gao, Lu-Lu; Chen, Yi-xiong; Cai, Lian-gong; Chen, Qing; Yu, Shou-yi
2008-05-01
To develop an simple and sensitive method for detecting anti-coronavirus IgG antibodies in bat sera based on enzyme-linked immunosorbent assay (ELISA). A commercial ELISA kit for detecting SARS-CoV antibody was modified for detecting coronavirus antibodies in bat serum samples. The second antibody in the kit was replaced with horseradish peroxidase-conjugated protein-A (HRP-SPA) based on the characteristics of binding between Staphylococcus aureus protein A (SPA) and mammal IgG Fc fragment. The sera of 55 fulvous fruit bats (Rousettus dasymallus) were tested using the SPA-ELISA. The test results of the positive and negative controls in the kit and the serum samples from convalescent ;patient were consistent with expectation. Coronavirus antibody was detected in 2 out of the 55 bat serum samples. Serum neutralization test confirmed the validity of the SPA-ELISA method. This SPA-ELISA method is applicable for detecting coronavirus antibody in bat sera.
Bowers, Alex R.; Tant, Mark; Peli, Eli
2012-01-01
Aims. Homonymous hemianopia (HH), a severe visual consequence of stroke, causes difficulties in detecting obstacles on the nonseeing (blind) side. We conducted a pilot study to evaluate the effects of oblique peripheral prisms, a novel development in optical treatments for HH, on detection of unexpected hazards when driving. Methods. Twelve people with complete HH (median 49 years, range 29–68) completed road tests with sham oblique prism glasses (SP) and real oblique prism glasses (RP). A masked evaluator rated driving performance along the 25 km routes on busy streets in Ghent, Belgium. Results. The proportion of satisfactory responses to unexpected hazards on the blind side was higher in the RP than the SP drive (80% versus 30%; P = 0.001), but similar for unexpected hazards on the seeing side. Conclusions. These pilot data suggest that oblique peripheral prisms may improve responses of people with HH to blindside hazards when driving and provide the basis for a future, larger-sample clinical trial. Testing responses to unexpected hazards in areas of heavy vehicle and pedestrian traffic appears promising as a real-world outcome measure for future evaluations of HH rehabilitation interventions aimed at improving detection when driving. PMID:23316415
Simpson, C.; Shirodaria, P. V.; Evans, J. P.; Simpson, D. I.; Stanford, C. F.
1992-01-01
AIMS: To compare the sensitivity of two methods for the detection of serum antibodies to pigeon faecal antigens in patients with pigeon breeder's disease. METHODS: Serum samples stored at -20 degrees C from 50 patients with pigeon breeder's disease, 50 control samples from patients with other respiratory diseases, and 50 healthy blood donors were examined for the precipitating antibodies and IgG antibodies to antigens present in extract of pigeon droppings by immunodiffusion and enzyme linked immunosorbent assay (ELISA), respectively. RESULTS: Both antigen preparations of pigeon dropping extract were equally effective. A positive immunodiffusion reaction gave one or more precipitin lines and these antibodies were detected only in undiluted sera from 80% of the patients with pigeon breeder's disease. In the ELISA the sera were tested at a starting dilution of 1 in 100 because positive reactions were observed with sera from healthy blood donors at lower dilutions. All sera which gave optical density readings above 3 SD of the control value were considered to have IgG antibodies. These antibodies were detected in sera from all the patients with pigeon breeder's disease. The antibody titres were much higher in those patients who had precipitating antibodies (range 800-51,200) than those without (range 100-800). The antibodies were not detected in the sera of patients with respiratory diseases or healthy blood donors by either method. CONCLUSIONS: Antibodies to pigeon dropping antigens were detected by immunodiffusion and ELISA in sera from patients with pigeon breeder's disease but not in control sera. ELISA was a more sensitive method for detecting antibodies and therefore seems to have considerable potential as a routine technique in the serological diagnosis of pigeon breeder's disease. PMID:1624596
Florek, Nicholas W; Weinfurter, Jason T; Jegaskanda, Sinthujan; Brewoo, Joseph N; Powell, Tim D; Young, Ginger R; Das, Subash C; Hatta, Masato; Broman, Karl W; Hungnes, Olav; Dudman, Susanne G; Kawaoka, Yoshihiro; Kent, Stephen J; Stinchcomb, Dan T; Osorio, Jorge E; Friedrich, Thomas C
2014-11-01
Current influenza virus vaccines primarily aim to induce neutralizing antibodies (NAbs). Modified vaccinia virus Ankara (MVA) is a safe and well-characterized vector for inducing both antibody and cellular immunity. We evaluated the immunogenicity and protective efficacy of MVA encoding influenza virus hemagglutinin (HA) and/or nucleoprotein (NP) in cynomolgus macaques. Animals were given 2 doses of MVA-based vaccines 4 weeks apart and were challenged with a 2009 pandemic H1N1 isolate (H1N1pdm) 8 weeks after the last vaccination. MVA-based vaccines encoding HA induced potent serum antibody responses against homologous H1 or H5 HAs but did not stimulate strong T cell responses prior to challenge. However, animals that received MVA encoding influenza virus HA and/or NP had high frequencies of virus-specific CD4(+) and CD8(+) T cell responses within the first 7 days of H1N1pdm infection, while animals vaccinated with MVA encoding irrelevant antigens did not. We detected little or no H1N1pdm replication in animals that received vaccines encoding H1 (homologous) HA, while a vaccine encoding NP from an H5N1 isolate afforded no protection. Surprisingly, H1N1pdm viral shedding was reduced in animals vaccinated with MVA encoding HA and NP from an H5N1 isolate. This reduced shedding was associated with cross-reactive antibodies capable of mediating antibody-dependent cellular cytotoxicity (ADCC) effector functions. Our results suggest that ADCC plays a role in cross-protective immunity against influenza. Vaccines optimized to stimulate cross-reactive antibodies with ADCC function may provide an important measure of protection against emerging influenza viruses when NAbs are ineffective. Current influenza vaccines are designed to elicit neutralizing antibodies (NAbs). Vaccine-induced NAbs typically are effective but highly specific for particular virus strains. Consequently, current vaccines are poorly suited for preventing the spread of newly emerging pandemic viruses. Therefore, we evaluated a vaccine strategy designed to induce both antibody and T cell responses, which may provide more broadly cross-protective immunity against influenza. Here, we show in a translational primate model that vaccination with a modified vaccinia virus Ankara encoding hemagglutinin from a heterosubtypic H5N1 virus was associated with reduced shedding of a pandemic H1N1 virus challenge, while vaccination with MVA encoding nucleoprotein, an internal viral protein, was not. Unexpectedly, this reduced shedding was associated with nonneutralizing antibodies that bound H1 hemagglutinin and activated natural killer cells. Therefore, antibody-dependent cellular cytotoxicity (ADCC) may play a role in cross-protective immunity to influenza virus. Vaccines that stimulate ADCC antibodies may enhance protection against pandemic influenza virus. Copyright © 2014, American Society for Microbiology. All Rights Reserved.
Florek, Nicholas W.; Weinfurter, Jason T.; Jegaskanda, Sinthujan; Brewoo, Joseph N.; Powell, Tim D.; Young, Ginger R.; Das, Subash C.; Hatta, Masato; Broman, Karl W.; Hungnes, Olav; Dudman, Susanne G.; Kawaoka, Yoshihiro; Kent, Stephen J.; Stinchcomb, Dan T.
2014-01-01
ABSTRACT Current influenza virus vaccines primarily aim to induce neutralizing antibodies (NAbs). Modified vaccinia virus Ankara (MVA) is a safe and well-characterized vector for inducing both antibody and cellular immunity. We evaluated the immunogenicity and protective efficacy of MVA encoding influenza virus hemagglutinin (HA) and/or nucleoprotein (NP) in cynomolgus macaques. Animals were given 2 doses of MVA-based vaccines 4 weeks apart and were challenged with a 2009 pandemic H1N1 isolate (H1N1pdm) 8 weeks after the last vaccination. MVA-based vaccines encoding HA induced potent serum antibody responses against homologous H1 or H5 HAs but did not stimulate strong T cell responses prior to challenge. However, animals that received MVA encoding influenza virus HA and/or NP had high frequencies of virus-specific CD4+ and CD8+ T cell responses within the first 7 days of H1N1pdm infection, while animals vaccinated with MVA encoding irrelevant antigens did not. We detected little or no H1N1pdm replication in animals that received vaccines encoding H1 (homologous) HA, while a vaccine encoding NP from an H5N1 isolate afforded no protection. Surprisingly, H1N1pdm viral shedding was reduced in animals vaccinated with MVA encoding HA and NP from an H5N1 isolate. This reduced shedding was associated with cross-reactive antibodies capable of mediating antibody-dependent cellular cytotoxicity (ADCC) effector functions. Our results suggest that ADCC plays a role in cross-protective immunity against influenza. Vaccines optimized to stimulate cross-reactive antibodies with ADCC function may provide an important measure of protection against emerging influenza viruses when NAbs are ineffective. IMPORTANCE Current influenza vaccines are designed to elicit neutralizing antibodies (NAbs). Vaccine-induced NAbs typically are effective but highly specific for particular virus strains. Consequently, current vaccines are poorly suited for preventing the spread of newly emerging pandemic viruses. Therefore, we evaluated a vaccine strategy designed to induce both antibody and T cell responses, which may provide more broadly cross-protective immunity against influenza. Here, we show in a translational primate model that vaccination with a modified vaccinia virus Ankara encoding hemagglutinin from a heterosubtypic H5N1 virus was associated with reduced shedding of a pandemic H1N1 virus challenge, while vaccination with MVA encoding nucleoprotein, an internal viral protein, was not. Unexpectedly, this reduced shedding was associated with nonneutralizing antibodies that bound H1 hemagglutinin and activated natural killer cells. Therefore, antibody-dependent cellular cytotoxicity (ADCC) may play a role in cross-protective immunity to influenza virus. Vaccines that stimulate ADCC antibodies may enhance protection against pandemic influenza virus. PMID:25210172
Generalized platform for antibody detection using the antibody catalyzed water oxidation pathway.
Welch, M Elizabeth; Ritzert, Nicole L; Chen, Hongjun; Smith, Norah L; Tague, Michele E; Xu, Youyong; Baird, Barbara A; Abruña, Héctor D; Ober, Christopher K
2014-02-05
Infectious diseases, such as influenza, present a prominent global problem including the constant threat of pandemics that initiate in avian or other species and then pass to humans. We report a new sensor that can be specifically functionalized to detect antibodies associated with a wide range of infectious diseases in multiple species. This biosensor is based on electrochemical detection of hydrogen peroxide generated through the intrinsic catalytic activity of all antibodies: the antibody catalyzed water oxidation pathway (ACWOP). Our platform includes a polymer brush-modified surface where specific antibodies bind to conjugated haptens with high affinity and specificity. Hydrogen peroxide provides an electrochemical signal that is mediated by Resorufin/Amplex Red. We characterize the biosensor platform, using model anti-DNP antibodies, with the ultimate goal of designing a versatile device that is inexpensive, portable, reliable, and fast. We demonstrate detection of antibodies at concentrations that fall well within clinically relevant levels.
Concordance of polymerase chain reaction with human immunodeficiency virus antibody detection.
Horsburgh, C R; Ou, C Y; Jason, J; Holmberg, S D; Lifson, A R; Moore, J L; Ward, J W; Seage, G R; Mayer, K H; Evatt, B L
1990-08-01
To evaluate the correlation of detection of human immunodeficiency virus (HIV) by polymerase chain reaction (PCR) with detection of HIV antibody, 271 simultaneous serum and peripheral blood mononuclear cell samples were examined from 242 persons whose activities placed them at increased risk for HIV infection: 142 from homosexual men, 86 from hemophilic men, and 43 from heterosexual partners of HIV-infected persons. PCR was performed using the gag region primer pair SK38/39 and the env region primer pairs SK68/69 and CO71/72. Amplified HIV DNA was detected using specific oligomer probes. Of 63 HIV antibody-positive samples, 58 (92%) had HIV DNA by PCR. Of 208 HIV antibody-negative samples, 7 (3.4%) had HIV DNA by PCR. On follow-up, 4 of the latter persons were seropositive when next tested; 2 were well and antibody- and PCR-negative; 1 had died of a stroke before retesting. Thus, PCR detects HIV in most antibody-positive persons; detection is increased by use of multiple primer pairs. PCR-positive antibody-negative specimens may indicate HIV infection in which antibody has not yet developed or may be false-positive PCR results. When PCR is discordant with HIV antibody, testing of additional specimens and clinical follow-up are necessary to assess HIV infection status.
Egg yolk antibodies for detection and neutralization of Clostridium botulinum type A neurotoxin.
Trott, D L; Yang, M; Gonzalez, J; Larson, A E; Tepp, W H; Johnson, E A; Cook, M E
2009-05-01
The objective of this research project was to determine the usefulness of an egg antibody platform for producing materials for the detection and neutralization of botulinum type A neurotoxin. Yield estimates for detection and neutralizing antibodies produced using methods described were calculated. Antibody specific to botulinum toxoid A (aToxoid) and toxin A (aBoNT/A) was produced by immunizing hens with botulinum toxoid A (toxoid) followed by increasing amounts of botulinum neurotoxin A (BoNT/A) in Freund incomplete adjuvant. Egg yolks were extracted with polyethylene glycol (PEG) for antibody detection and neutralization experiments. A model aToxoid/toxoid immunoassay using only egg yolk antibody was developed and had a detection limit of 1 pg/ml of toxoid. In an indirect enzyme-linked immunosorbent assay of BoNT/A-specific antibody, the aBoNT/A contained more BoNT/A-specific antibody than did the aToxoid, and aBoNT/A was as effective as commercial rabbit antibody. The aToxoid provided no protection against BoNT/A in a standard mouse neutralization assay; however, 1 mg of PEG-extracted aBoNT/A neutralized 4,000 lethal doses of BoNT/A injected intraperitoneally. Based on these results, we calculated that in 1 month one hen could produce more than 100 liters of antibody detection reagents or enough antibody to neutralize approximately 11.6 million mouse lethal doses of botulinum toxin. Utilization of an egg antibody platform is potentially rapid (28 to 70 days) and scalable to kilogram quantities using current egg production facilities with as few as 1,000 hens.
Chaya, Dr; Parija, Subhash Chandra
2013-07-01
Cystic echinococcosis (CE) is a zoonotic disease of humans with variable clinical manifestations. Imaging and immunological methods are currently the mainstay of diagnosis of this disease. Although the immunological tests for detection of anti-echinococcal antibodies have several disadvantages, they are widely being used. Antigen is far more superior than antibody detection test as they can provide a specific parasitic diagnosis. A sandwich enzyme linked immunosorbent assay (ELISA) was designed using antibodies to 24 kDa urinary hydatid antigen for the detection of hydatid antigens in urine, serum and cyst fluid specimens. The performance of this novel test was compared with that of other hydatid antibody detection ELISA and enzyme immune transfer blot (EITB) using radiological and surgical confirmation as the gold standard. The antigen detection ELISA showed 100% sensitivity and specificity when tested with cyst fluid. On testing urine and serum, the antigen detection ELISA was found to be more specific than antibody detection ELISA. EITB was found to be the most sensitive and specific test. ELISA using polyclonal antibodies against 24 kDa urinary hydatid protein was moderately sensitive to detect hydatid antigen in serum and urine. Hence polyclonal antibodies to 24 kDa urinary hydatid antigen can be used as an alternative source of antibody to detect hydatid antigen in serum, urine and cyst fluid. In the present study, EITB was found to be highly specific test for detection of hydatid antibodiesin serum. 24 kDa protein was found to be specific and of diagnostic value in CE.
Onodera, Rie; Kurita, Emi; Taniguchi, Kikuyo; Karakawa, Shuhei; Okada, Satoshi; Kihara, Hirotaka; Fujii, Teruhisa; Kobayashi, Masao
2017-11-01
Anti-human neutrophil antigen (HNA) antibodies have been implicated in the development of neonatal alloimmune neutropenia (NAN) and autoimmune neutropenia (AIN). There are many conventional assay methods that detect anti-HNA antibodies. However, a method to measure multiple samples and detect several anti-HNA antibodies simultaneously is needed. We developed a new method, the extracted granulocyte antigen immunofluorescence assay (EGIFA), to analyze anti-HNA-1a, -1b, and -2 antibodies in sera. The results obtained by EGIFA were evaluated in comparison with those from several standard assay methods. Anti-HNA antibodies in serum samples from nine familial cases with suspected NAN (n = 19) and children with suspected AIN (n = 88) were also measured by EGIFA. The evaluation of nine serum samples with anti-HNA antibodies suggested that EGIFA demonstrated equivalent specificity and superior sensitivity to monoclonal antibody-specific immobilization of granulocyte antigens and had comparable sensitivity to the granulocyte indirect immunofluorescence test. EGIFA successfully detected anti-HNA-1a or -1b antibodies in seven of nine familial cases with suspected NAN. EGIFA detected anti-HNA antibodies in 40.9% of children with suspected AIN. Among them, isolated anti-HNA-1a or -1b antibody was detected in 4.5 or 12.5% of children, respectively, and anti-HNA-2 antibody was identified in 3.4% of children. The 30.8% (16 of 52) of children negative for anti-HNA antibody by EGIFA were positive for anti-HLA antibody. EGIFA facilitated the measurement of anti-HNA-1a, -1b, and/or -2 antibodies in sera. The prompt measurement of anti-HNA antibodies will improve the diagnosis and clinical management of patients with suspected NAN or AIN. © 2017 AABB.
Antibody class capture assays for varicella-zoster virus.
Forghani, B; Myoraku, C K; Dupuis, K W; Schmidt, N J
1984-01-01
Pooled monoclonal antibodies to varicella-zoster virus (VZV) were used as "detector" antibodies in a four-phase enzyme immunofluorescence assay for determination of immunoglobulin M (IgM), IgA, and IgG antibodies to VZV. Polyclonal antisera specific for heavy chains of human IgM, IgA, and IgG were employed as "capture" antibodies on the solid phase. The antibody class capture assay (ACCA) for VZV IgM antibody detected high titers of virus-specific IgM in all patients with varicella and in 5 of 10 zoster patients. VZV IgM antibody was not detected in patients with primary herpes simplex virus infections or in other individuals without active VZV infection, with one exception, a patient with encephalitis who had other serological findings compatible with a reactivated VZV infection. VZV-specific IgA and IgG antibody titers demonstrable by ACCA were compared with those measured by solid-phase indirect enzyme immunofluorescence assay (EIFA). VZV IgA antibody titers detected in patients with varicella and zoster were variable and could not be considered to be reliable markers of active VZV infection. IgA antibody titers detected by ACCA tended to be higher than those demonstrated by solid-phase indirect EIFA in varicella and zoster patients. VZV IgG antibody titers detected by ACCA in patients with varicella, and to a lesser extent in zoster patients, were as high as or higher than those demonstrated by solid-phase indirect EIFA. However, ACCA was totally insensitive in detecting VZV IgG antibody in individuals with past infections with VZV and would not be a suitable approach for determination of immunity status to VZV. PMID:6330163
Ota, Shusuke; Kanazawa, Satoshi; Kobayashi, Masaaki; Otsuka, Takanobu; Okamoto, Takashi
2005-04-01
Antibodies to type II collagen (col II) have been detected in patients with rheumatoid arthritis and in animal models of collagen induced arthritis. Here, we describe a novel method to detect anti-col II antibodies using an immunospot assay with an infrared fluorescence imaging system. This method showed very high sensitivity and specificity, and was simple, with low background levels. It also showed higher reproducibility and linearity, with a dynamic range of approximately 500-fold, than the conventional immunospot assay with enhanced chemiluminescence detection. Using this method we were able to demonstrate the antibody affinity maturation process in mice immunized with col II. In these immunized mice, although cross-reactive antibodies reacting with other collagen species were detected in earlier stages of immunization, the titers of cross-reactive antibodies rapidly diminished after the antigen boost, concomitantly with the elevation of the anti-col II antibody. The method and its possible applications are discussed.
[Comparison of several methods for detecting anti-erythrocyte alloantibodies].
Bencomo, A A
1990-08-01
The efficacy of different methods for anti-red cell antibodies detection was assessed, variations being found in accordance with the specificity of the alloantibodies. The usefulness of enzyme tests in anti-Rh antibody detection was demonstrated, as well as that of low ionic strength saline solutions in detecting anti-Kell, anti-Duffy and anti-Kidd antibodies. Serum precipitation with 15% polyethyleneglycol 8000 previously to indirect antiglobulin test was found the most sensitive method, providing the best results in all the antibodies studied.
Wellehan, James F X; Green, Linda G; Duke, Diane G; Bootorabi, Shadi; Heard, Darryl J; Klein, Paul A; Jacobson, Elliott R
2009-09-01
Megachiropteran bats are biologically important both as endangered species and reservoirs for emerging human pathogens. Reliable detection of antibodies to specific pathogens in bats is thus epidemiologically critical. Eight variable flying foxes (Pteropus hypomelanus) were immunized with 2,4-dinitrophenylated bovine serum albumin (DNP-BSA). Each bat received monthly inoculations for 2 months. Affinity-purified IgG was used for production of polyclonal and monoclonal anti-variable flying fox IgG antibodies. ELISA and western blot analysis were used to monitor immune responses and for assessment of polyclonal and monoclonal antibody species cross-reactivity. Protein G, polyclonal antibodies, and monoclonal antibodies detected specific anti-DNP antibody responses in immunized variable flying foxes, with protein G being the most sensitive, followed by monoclonal antibodies and then polyclonal antibodies. While the polyclonal antibody was found to cross-react well against IgG of all bat species tested, some non-specific background was observed. The monoclonal antibody was found to cross-react well against IgG of six other species in the genus Pteropus and to cross-react less strongly against IgG from Eidolon helvum or Phyllostomus hastatus. Protein G distinguished best between vaccinated and unvaccinated bats, and these results validate the use of protein G for detection of bat IgG. Monoclonal antibodies developed in this study recognized immunoglobulins from other members of the genus Pteropus well, and may be useful in applications where specific detection of Pteropus IgG is needed.
Su, Mengna; Venkatachalam, Mahesh; Liu, Changqi; Zhang, Ying; Roux, Kenneth H; Sathe, Shridhar K
2013-11-13
A sandwich enzyme-linked immunosorbent assay (ELISA) using anti-almond soluble protein rabbit polyclonal antibodies as capture antibodies and murine monoclonal antibody 4C10 as the detection antibodies was developed. The assay is specific and sensitive (3-200 ng almond protein/mL) for almond detection. The standardized assay is accurate (<15% CV) and reproducible (intra- and inter assay variability <15% CV). The assay did not register any cross-reactivity with the tested food matrices, suggesting the assay to be almond amandin specific. The assay could detect the presence of declared almond in the tested matched commercial samples. Further, the assay reliably detected the presence of almonds in the laboratory prepared food samples spiked with almond flour.
Yeo, T; Chen, Z; Chai, J Y H; Tan, K
2017-07-15
The presence of VGKC-complex antibodies, without LGI1/CASPR2 antibodies, as a standalone marker for neurological autoimmunity remains controversial. Additionally, the lack of an unequivocal VGKC-complex antibody cut-off level defining neurological autoimmunity makes it important to test for monospecific antibodies. We aim to determine the performance characteristics of a commercial assay (Euroimmun, Lübeck, Germany) for LGI1/CASPR2 antibody detection in patients with very high VGKC-complex antibody levels and report their clinico-serological associations. We identified 8 patients in our cohort with the highest VGKC-complex antibody levels (median 2663.5pM, range 933-6730pM) with VGKC-complex antibody related syndromes (Group A). Two other groups were identified; 1 group with suspected neuronal surface antibody syndromes and negative for VGKC-complex antibodies (Group B, n=8), and another group with cerebellar ataxia and negative for onconeuronal antibodies (Group C, n=8). Seven out of 8 patients (87.5%) in Group A had LGI1 and/or CASPR2 antibodies. One Group B patient had LGI1 antibodies but was negative on re-testing with a live cell assay. No Group C patients had monospecific antibodies. Inter-rater reliability was high; combining Groups A and B patients, the kappa statistic was 0.87 and 1.0 for LGI1 and CASPR2 antibodies respectively. We demonstrated that a high proportion of patients with very high VGKC-complex antibody levels and relevant clinical syndromes have LGI1 and/or CASPR2 antibodies detected by the commercial assay. Our findings lend support to the use of the assay for rapid and reliable detection of LGI1 and CASPR2 antibodies. Copyright © 2017 Elsevier B.V. All rights reserved.
Li, Wenhua; Yang, Bin; Zhou, Dongmei; Xu, Jun; Ke, Zhi; Suen, Wen-Chen
2016-07-01
Liquid chromatography mass spectrometry (LC-MS) is the most commonly used technique for the characterization of antibody variants. MAb-X and mAb-Y are two approved IgG1 subtype monoclonal antibody drugs recombinantly produced in Chinese hamster ovary (CHO) cells. We report here that two unexpected and rare antibody variants have been discovered during cell culture process development of biosimilars for these two approved drugs through intact mass analysis. We then used comprehensive mass spectrometry-based comparative analysis including reduced light, heavy chains, and domain-specific mass as well as peptide mapping analysis to fully characterize the observed antibody variants. The "middle-up" mass comparative analysis demonstrated that the antibody variant from mAb-X biosimilar candidate was caused by mass variation of antibody crystalline fragment (Fc), whereas a different variant with mass variation in antibody antigen-binding fragment (Fab) from mAb-Y biosimilar candidate was identified. Endoproteinase Lys-C digested peptide mapping and tandem mass spectrometry analysis further revealed that a leucine to glutamine change in N-terminal 402 site of heavy chain was responsible for the generation of mAb-X antibody variant. Lys-C and trypsin coupled non-reduced and reduced peptide mapping comparative analysis showed that the formation of the light-heavy interchain trisulfide bond resulted in the mAb-Y antibody variant. These two cases confirmed that mass spectrometry-based comparative analysis plays a critical role for the characterization of monoclonal antibody variants, and biosimilar developers should start with a comprehensive structural assessment and comparative analysis to decrease the risk of the process development for biosimilars. Copyright © 2016 Elsevier B.V. All rights reserved.
Cazenave, P. -A.; Ternynck, T.; Avrameas, S.
1974-01-01
The occurrence of immunoglobulins with and without antibody specificity and with and without idiotypic specificity was studied, by use of enzyme-labeled antigen and antibodies, in lymph node cells of rabbits immunized with horse-radish peroxidase and hen ovalbumin. Some cells, containing immunoglobulins without detectable antibody function, were shown to contain idiotypes similar to those found in antibody-producing cells. PMID:4140504
Serum antibody titers following routine rabies vaccination in African elephants.
Miller, Michele A; Olea-Popelka, Francisco
2009-10-15
To evaluate serum antibody titers in captive African elephants (Loxodonta africana) following routine vaccination with a commercially available, inactivated rabies vaccine. Seroepidemiologic study. 14 captive African elephants from a single herd. Elephants were vaccinated as part of a routine preventive health program. Initially, elephants were vaccinated annually (2 mL, IM), and blood was collected every 4 or 6 months for measurement of rabies virus-neutralizing antibody titer by means of the rapid fluorescent focus inhibition test. Individual elephants were later switched to an intermittent vaccination schedule to allow duration of the antibody response to be determined. All elephants had detectable antibody responses following rabies vaccination, although there was great variability among individual animals in regard to antibody titers, and antibody titers could be detected as long as 24 months after vaccine administration. Young animals were found to develop an antibody titer following administration of a single dose of the rabies vaccine. Age and time since vaccination had significant effects on measured antibody titers. Results indicated that African elephants developed detectable antibody titers in response to inoculation with a standard large animal dose of a commercially available, inactivated rabies vaccine. The persistence of detectable antibody titers in some animals suggested that vaccination could be performed less frequently than once a year if antibody titers were routinely monitored.
Erdman, D D; Heath, J L; Watson, J C; Markowitz, L E; Bellini, W J
1993-09-01
The use of IgM antibody detection for the classification of the primary and secondary measles antibody response in persons following primary and secondary vaccination and natural measles virus infection was examined. Of 32 nonimmune children receiving primary measles vaccination, 31 (97%) developed IgM antibodies, consistent with a primary antibody response. Of 21 previously vaccinated children with low levels of preexisting IgG antibodies who responded to revaccination, none developed detectable IgM antibodies, whereas 33 of 35 (94%) with no detectable preexisting IgG antibodies developed an IgM response. Of a sample of 57 measles cases with a prior history of vaccination, 55 (96%) had detectable IgM antibodies. Of these, 30 (55%) were classified as having a primary antibody response and 25 (45%) a secondary antibody response based on differences in their ratios of IgM to IgG antibodies. Differences in the severity of clinical symptoms between these 2 groups were consistent with this classification scheme. These findings suggest that 1) an IgM response follows primary measles vaccination in the immunologically naive, 2) an IgM response is absent on revaccination of those previously immunized, and 3) an IgM response may follow clinical measles virus infection independent of prior immunization status.
Chaya, DR; Parija, Subhash Chandra
2013-01-01
Introduction: Cystic echinococcosis (CE) is a zoonotic disease of humans with variable clinical manifestations. Imaging and immunological methods are currently the mainstay of diagnosis of this disease. Although the immunological tests for detection of anti-echinococcal antibodies have several disadvantages, they are widely being used. Antigen is far more superior than antibody detection test as they can provide a specific parasitic diagnosis. Materials and Methods: A sandwich enzyme linked immunosorbent assay (ELISA) was designed using antibodies to 24 kDa urinary hydatid antigen for the detection of hydatid antigens in urine, serum and cyst fluid specimens. The performance of this novel test was compared with that of other hydatid antibody detection ELISA and enzyme immune transfer blot (EITB) using radiological and surgical confirmation as the gold standard. Results: The antigen detection ELISA showed 100% sensitivity and specificity when tested with cyst fluid. On testing urine and serum, the antigen detection ELISA was found to be more specific than antibody detection ELISA. EITB was found to be the most sensitive and specific test. Conclusions: ELISA using polyclonal antibodies against 24 kDa urinary hydatid protein was moderately sensitive to detect hydatid antigen in serum and urine. Hence polyclonal antibodies to 24 kDa urinary hydatid antigen can be used as an alternative source of antibody to detect hydatid antigen in serum, urine and cyst fluid. In the present study, EITB was found to be highly specific test for detection of hydatid antibodiesin serum. 24 kDa protein was found to be specific and of diagnostic value in CE. PMID:24470996
Nato, F; Mazie, J C; Fournier, J M; Slizewicz, B; Sagot, N; Guibourdenche, M; Postic, D; Riou, J Y
1991-01-01
Polyclonal and monoclonal antibodies against capsular polysaccharides of Neisseria meningitidis serogroups A, B, and C were produced in order to develop immunological reagents allowing both the detection of soluble antigens during meningococcal meningitis and antigenic serogrouping of N. meningitidis cultures. The performance characteristics of monoclonal and polyclonal antibody latex reagents were compared. For the detection of soluble polysaccharide antigen, polyclonal antibody latex reagent was selected for N. meningitidis A and C. The latex reagent prepared with polyclonal antibodies against N. meningitidis B could not detect capsular polysaccharide even at 1 mg/ml. The monoclonal antibody B latex reagent which detected 100 ng of polysaccharide per ml was therefore chosen. For the serogroup identification of N. meningitidis, the use of a confirmatory test results in an overall specificity of 100% with polyclonal or monoclonal antibody latex reagents. PMID:1909346
Di Cristofaro, Julie; Frassati, Coralie; Montagnie, Rolande; Basire, Agnes; Merieux, Yves; Picard, Christophe
2015-01-01
Fetal/neonatal allo-immune thrombocytopenia is the most frequent and the most dangerous clinical condition involving anti-human platelet antigens (HPA)-1a allo-antibodies. Anti-HPA-1a allo-immunization requires rapid and accurate diagnosis to determine appropriate treatment. The Capture-P Ready-Screen assay (C-PRS) is a new qualitative immunoassay to detect IgG anti-human leukocyte antigen (HLA) and anti-HPA allo-antibodies. The aim of this study is to assess the identification of anti-HPA-1a allo-antibodies using the C-PRS assay, associated with HLA class I stripping reagents, on the automated benchtop analyzer Galileo Echo. Forty-nine sera were analyzed: without anti-HLA class I or anti-HPA allo-antibodies, with anti-HLA class I allo-antibodies, with anti-HPA-1a allo-antibodies, among which with anti-HLA class I allo-antibodies. None of the samples without allo-antibodies were reactive. Only anti-HLA antibodies, detected by cytotoxicity-dependent complement and not by Luminex, remained positive before and after stripping reagents. Of the 13 samples, anti-HPA-1a allo-antibodies that were correctly identified before and after incubation with HLA assassin reagent were 70% and 85%, respectively. Anti-glycoprotein auto-antibodies and anti-HLA allo-antibodies do not interfere with the detection of anti-HPA-1a antibodies. This preliminary study indicates that further improvement of the test will be helpful in developing a clinically useful assay in the future.
NASA Astrophysics Data System (ADS)
Frampton, John P.; White, Joshua B.; Simon, Arlyne B.; Tsuei, Michael; Paczesny, Sophie; Takayama, Shuichi
2014-05-01
Accurate disease diagnosis, patient stratification and biomarker validation require the analysis of multiple biomarkers. This paper describes cross-reactivity-free multiplexing of enzyme-linked immunosorbent assays (ELISAs) using aqueous two-phase systems (ATPSs) to confine detection antibodies at specific locations in fully aqueous environments. Antibody cross-reactions are eliminated because the detection antibody solutions are co-localized only to corresponding surface-immobilized capture antibody spots. This multiplexing technique is validated using plasma samples from allogeneic bone marrow recipients. Patients with acute graft versus host disease (GVHD), a common and serious condition associated with allogeneic bone marrow transplantation, display higher mean concentrations for four multiplexed biomarkers (HGF, elafin, ST2 and TNFR1) relative to healthy donors and transplant patients without GVHD. The antibody co-localization capability of this technology is particularly useful when using inherently cross-reactive reagents such as polyclonal antibodies, although monoclonal antibody cross-reactivity can also be reduced. Because ATPS-ELISA adapts readily available antibody reagents, plate materials and detection instruments, it should be easily transferable into other research and clinical settings.
Enhanced biosensor performance using an avidin-biotin bridge for antibody immobilization
NASA Astrophysics Data System (ADS)
Narang, Upvan; Anderson, George P.; King, Keeley D.; Liss, Heidi S.; Ligler, Frances S.
1997-05-01
Maintaining antibody function after immobilization is critical to the performance of a biosensor. The conventional methods to immobilize antibodies onto surfaces are via covalent attachment using a crosslinker or by adsorption. Often, these methods of immobilization result in partial denaturation of the antibody and conformational changes leading to a reduced activity of the antibody. In this paper, we report on the immobilization of antibodies onto the surface of an optical fiber through an avidin-biotin bridge for the detection of ricin, ovalbumin, and Bacillus globigii (Bg). The assays are performed in a sandwich format. First, a capture antibody is immobilized, followed by the addition of the analyte. Finally, a fluorophore- labeled antibody is added for the specific detection of the analyte. The evanescent wave-induced fluorescence is coupled back through the same fiber to be detected using a photodiode. In all cases, we observe an improved performance of the biosensor, i.e., lower limit of detection and wide linear dynamic range, for the assays in which the antibody is immobilized via avidin-biotin bridges compared to covalent attachment method.
Frampton, John P.; White, Joshua B.; Simon, Arlyne B.; Tsuei, Michael; Paczesny, Sophie; Takayama, Shuichi
2014-01-01
Accurate disease diagnosis, patient stratification and biomarker validation require the analysis of multiple biomarkers. This paper describes cross-reactivity-free multiplexing of enzyme-linked immunosorbent assays (ELISAs) using aqueous two-phase systems (ATPSs) to confine detection antibodies at specific locations in fully aqueous environments. Antibody cross-reactions are eliminated because the detection antibody solutions are co-localized only to corresponding surface-immobilized capture antibody spots. This multiplexing technique is validated using plasma samples from allogeneic bone marrow recipients. Patients with acute graft versus host disease (GVHD), a common and serious condition associated with allogeneic bone marrow transplantation, display higher mean concentrations for four multiplexed biomarkers (HGF, elafin, ST2 and TNFR1) relative to healthy donors and transplant patients without GVHD. The antibody co-localization capability of this technology is particularly useful when using inherently cross-reactive reagents such as polyclonal antibodies, although monoclonal antibody cross-reactivity can also be reduced. Because ATPS-ELISA adapts readily available antibody reagents, plate materials and detection instruments, it should be easily transferable into other research and clinical settings. PMID:24786974
Barr, Travis P; Kornberg, Daniel; Montmayeur, Jean-Pierre; Long, Melinda; Reichheld, Stephen; Strichartz, Gary R
2015-01-01
Antibodies are important tools for the study of protein expression but are often used without full validation. In this study, we used Western blots to characterize antibodies targeted to the N or C terminal (NT or CT, respectively) and the second or third intracellular loop (IL2 or IL3, respectively) of the endothelin B receptor (ETB). The IL2-targeted antibody accurately detected endogenous ETB expression in rat brain and cultured rat astrocytes by labeling a 50-kDa band, the expected weight of full-length ETB. However, this antibody failed to detect transfected ETB in HEK293 cultures. In contrast, the NT-targeted antibody accurately detected endogenous ETB in rat astrocyte cultures and transfected ETB in HEK293 cultures by labeling a 37-kDa band but failed to detect endogenous ETB in rat brain. Bands detected by the CT- or IL3-targeted antibody were found to be unrelated to ETB. Our findings show that functional ETB can be detected at 50 or 37kDa on Western blot, with drastic differences in antibody affinity for these bands. The 37-kDa band likely reflects ETB processing, which appears to be dependent on cell type and/or culture condition. Copyright © 2014 Elsevier Inc. All rights reserved.
Angiogenic cytokines are antibody targets during graft-versus-leukemia reactions
Piesche, Matthias; Ho, Vincent T.; Kim, Haesook; Nakazaki, Yukoh; Nehil, Michael; Yaghi, Nasser; Kolodin, Dmitriy; Weiser, Jeremy; Altevogt, Peter; Kiefel, Helena; Alyea, Edwin P.; Antin, Joseph H.; Cutler, Corey; Koreth, John; Canning, Christine; Ritz, Jerome; Soiffer, Robert J.; Dranoff, Glenn
2014-01-01
Purpose The graft-versus-leukemia (GVL) reaction is an important example of immune-mediated tumor destruction. A coordinated humoral and cellular response accomplishes leukemia cell killing, but the specific targets remain largely uncharacterized. To learn more about the antigens that elicit antibodies during GVL reactions, we analyzed advanced myelodysplasia (MDS) and acute myeloid leukemia (AML) patients who received an autologous, granulocyte-macrophage colony stimulating factor (GM-CSF) secreting tumor cell vaccine early after allogeneic hematopoietic stem cell transplantation (HSCT). Experimental Design A combination of tumor-derived cDNA expression library screening, protein microarrays, and antigen-specific ELISAs were employed to characterize sera obtained longitudinally from 15 AML/MDS patients who were vaccinated early after allogeneic HSCT. Results A broad, therapy-induced antibody response was uncovered, which primarily targeted intracellular proteins that function in growth, transcription/translation, metabolism, and homeostasis. Unexpectedly, antibodies were also elicited against eight secreted angiogenic cytokines that play critical roles in leukemogenesis. Antibodies to the angiogenic cytokines were evident early after therapy, and in some patients manifested a diversification in reactivity over time. Patients that developed antibodies to multiple angiogenic cytokines showed prolonged remission and survival. Conclusions These results reveal a potent humoral response during GVL reactions induced with vaccination early after allogeneic HSCT and raise the possibility that antibodies, in conjunction with NK cells and T lymphocytes, may contribute to immune-mediated control of myeloid leukemias. PMID:25538258
Fassbinder-Orth, Carol A.; Wilcoxen, Travis E.; Tran, Tiffany; Boughton, Raoul K.; Fair, Jeanne M.; Hofmeister, Erik K.; Grindstaff, Jennifer L.; Owen, Jen C.
2016-01-01
4.This study indicates that the anti-passerine IgY secondary antibody can effectively be used in immunological assays to detect passerine IgY for species in most passerine families and is preferred over anti-chicken and anti-bird secondary antibodies for the majority of passerine species. This anti-passerine antibody will allow for more accurate detection and quantification of IgY in more wild bird species than was possible with previously available secondary antibodies.
Maluping, Ramon P; Oronan, Rey B; Toledo, Steven U
2007-01-01
The present study was undertaken to detect the presence of Chlamydophila psittaci antibodies in captive birds at the Wildlife Rescue Center, Ninoy Aquino Parks and Wildlife Nature Center, Quezon City, Philippines. Blood was collected from 36 birds of different species and the presence of antibodies against C. psittaci was detected using an ELISA-based test kit. 25% of the samples demonstrated antibodies against C. psittaci. The results of this study confirmed the presence of C. psittaci antibodies among the captive birds examined.
La Rosa, Corinna; Limaye, Ajit P.; Krishnan, Aparna; Blumstein, Gideon; Longmate, Jeff; Diamond, Don J.
2012-01-01
Antiviral prophylaxis has proved successful for prevention of cytomegalovirus (CMV) disease in solid organ transplant (SOT) patients; though emerging data suggest that antiviral agents interfere with immunity, and may inhibit immune-priming. In this context, we investigated levels and phenotype of primary CMV-specific immune responses that developed during antiviral prophylaxis in a cohort of CMV seronegative recipients (R−) of a SOT from a seropositive donor (D+). We longitudinally monitored CMV viral load, antibodies and levels of the negative immuno-modulator IL-10. PBMC were stimulated with CMV-specific peptide libraries to measure CD137 activation marker on CMV-specific T-cells and levels of PD-1 receptor, which is overexpressed on exhausted T-cells. Unexpectedly, the majority (13/18) of D+R− patients who developed a primary CMV response showed early post-transplant CMV-specific responses, though levels of PD-1 on CMV-specific T-cells remained elevated throughout prophylaxis. A strong inverse association was found between levels of plasma IL-10 and CMV-specific cellular immune responses. Our study suggests that during prophylaxis, subclinical CMV infection might have occurred in the D+R− patients, and primary CMV-specific responses were detected early post-transplant when levels of plasma IL-10 were low. Extended prophylaxis or antiviral treatment did not appear to suppress CMV-specific antibodies or T-cells, which however showed exhaustion phenotypes. PMID:21672050
Chickpea chlorotic stunt virus: A New Polerovirus Infecting Cool-Season Food Legumes in Ethiopia.
Abraham, A D; Menzel, W; Lesemann, D-E; Varrelmann, M; Vetten, H J
2006-05-01
ABSTRACT Serological analysis of diseased chickpea and faba bean plantings with yellowing and stunting symptoms suggested the occurrence of an unknown or uncommon member of the family Luteoviridae in Ethiopia. Degenerate primers were used for reverse transcriptase-polymerase chain reaction amplification of the viral coat protein (CP) coding region from both chickpea and faba bean samples. Cloning and sequencing of the amplicons yielded nearly identical (96%) nucleotide sequences of a previously unrecognized species of the family Luteoviridae, with a CP amino acid sequence most closely related (identity of approximately 78%) to that of Groundnut rosette assistor virus. The complete genome (5,900 nts) of a faba bean isolate comprised six major open reading frames characteristic of polero-viruses. Of the four aphid species tested, only Aphis craccivora transmitted the virus in a persistent manner. The host range of the virus was confined to a few species of the family Fabaceae. A rabbit antiserum raised against virion preparations cross-reacted unexpectedly with Beet western yellows virus-like viruses. This necessitated the production of murine monoclonal antibodies which, in combination with the polyclonal antiserum, permitted both sensitive and specific detection of the virus in field samples by triple-antibody sandwich, enzyme-linked immunosorbent assay. Because of the characteristic field and greenhouse symptoms in chickpea, the name Chickpea chlorotic stunt virus is proposed for this new member of the genus Polerovirus (family Luteoviridae).
Lo, Chia-Yun; Strobl, Susan L; Dunham, Kimberly; Wang, Wei; Stewart, Lucy; Misplon, Julia A; Garcia, Mayra; Gao, Jin; Ozawa, Tatsuhiko; Price, Graeme E; Navidad, Jose; Gradus, Steve; Bhattacharyya, Sanjib; Viboud, Cecile; Eichelberger, Maryna C; Weiss, Carol D; Gorski, Jack; Epstein, Suzanne L
2017-01-01
Antibody and T-cell immunity to conserved influenza virus antigens can protect animals against infection with diverse influenza strains. Although immunity against conserved antigens occurs in humans, whether such responses provide cross-protection in humans and could be harnessed as the basis for universal influenza vaccines is controversial. The 2009 pandemic provided an opportunity to investigate whether pre-existing cross-reactive immunity affected susceptibility to infection. In 2009, we banked sera and peripheral blood mononuclear cells (PBMC) from blood donors, then monitored them for pandemic influenza infection (pH1N1) by polymerase chain reaction or seroconversion. Antibodies to hemagglutinin (HA), neuraminidase (NA), nucleoprotein (NP), matrix 2 (M2), and HA-pseudotypes were measured in sera. T-cell inteferon-γ enzyme-linked immunospot responses were measured in PBMC. There were 13 infections in 117 evaluable donors. Pre-existing T-cell reactivity to pH1N1 was substantial (of 153 donors tested, 146 had >100 spot-forming cells/10 6 cells). Antibodies reactive with pH1N1 were common: anti-NP (all donors) and anti-M2 (44% of donors). Pseudotype-neutralizing antibodies to H1 were detected, but not to highly conserved HA epitopes. Unexpectedly, donors with symptomatic pH1N1 infection had sharp rises in HA pseudotype-neutralizing antibodies, not only pH1N1 but also against multiple seasonal H1s. In addition, an exploratory study of a T-cell marker (response to NP 418-426 ) identified probable infection missed by standard criteria. Although the number of infections was inadequate for conclusions about mechanisms of protection, this study documents the wide variety of pre-existing, cross-reactive, humoral and cellular immune responses to pandemic influenza virus antigens in humans. These responses can be compared with results of other studies and explored in universal influenza vaccine studies. Published by Oxford University Press on behalf of Infectious Diseases Society of America 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.
The relationship between sustained inattentional blindness and working memory capacity.
Beanland, Vanessa; Chan, Esther Hiu Chung
2016-04-01
Inattentional blindness, whereby observers fail to detect unexpected stimuli, has been robustly demonstrated in a range of situations. Originally research focused primarily on how stimulus characteristics and task demands affect inattentional blindness, but increasingly studies are exploring the influence of observer characteristics on the detection of unexpected stimuli. It has been proposed that individual differences in working memory capacity predict inattentional blindness, on the assumption that higher working memory capacity confers greater attentional capacity for processing unexpected stimuli. Unfortunately, empirical investigations of the association between inattentional blindness and working memory capacity have produced conflicting findings. To help clarify this relationship, we examined the relationship between inattentional blindness and working memory capacity in two samples (Ns = 195, 147) of young adults. We used three common variants of sustained inattentional blindness tasks, systematically manipulating the salience of the unexpected stimulus and primary task practice. Working memory capacity, measured by automated operation span (both Experiments 1 & 2) and N-back (Experiment 1 only) tasks, did not predict detection of the unexpected stimulus in any of the inattentional blindness tasks tested. Together with previous research, this undermines claims that there is a robust relationship between inattentional blindness and working memory capacity. Rather, it appears that any relationship between inattentional blindness and working memory is either too small to have practical significance or is moderated by other factors and consequently varies with attributes such as the sample characteristics within a given study.
Monoclonal antibodies to cyclodiene insecticides and method for detecting the same
Stanker, Larry H.; Vanderlaan, Martin; Watkins, Bruce E.
1994-01-01
Methods are described for making specific monoclonal antibodies useful for detection of cyclodienes in foods and environmental samples. Monoclonal antibodies specifically reactive with cyclodienes can detect accumulated pesticides in food, tissue or environmental samples. Extraction and preparation of organic samples for immunoassay in a polar-nonpolar reaction medium permits detection of halogenated organic ring structures at concentrations in samples.
Morgeaux, S; Manniam, I; Variot, P; Daas, A; Costanzo, A
2015-01-01
The current batch of the European Pharmacopoeia (Ph. Eur.) Biological Reference Reagents (BRRs) used for the in vitro potency assay of hepatitis A vaccines (HAV) by ELISA (enzymelinked immunosorbent assay) was established in 2012 for use in conjunction with Ph. Eur. general chapter 2.7.14 Assay of hepatitis A vaccine. It is composed of a coating reagent and a set of detection antibodies. As stocks of the latter are running low, the European Directorate for the Quality of Medicines & HealthCare (EDQM) organised a collaborative study to qualify replacement batches. The candidate BRR antibodies (primary monoclonal antibody and labelled secondary antibody) were prepared under appropriate conditions from starting materials similar to those used for the current batches. The new batches of antibodies were tested alongside previous batches of BRRs to ensure continuity, and the results confirmed that they were suitable for use in the potency assay of hepatitis A vaccines by ELISA using the standard method referenced in Ph. Eur. general chapter 2.7.14 at the same final concentrations as the previous batches, i.e. 1:500 for the primary monoclonal antibody and 1:400 for the secondary conjugated antibody. The outcome of the study allowed their establishment by the Ph. Eur. Commission in March 2015 as anti-hepatitis A virus primary detection antibody BRR batch 3 and conjugated secondary detection antibody BRR batch 3 respectively. They are available from the EDQM as hepatitis A vaccine ELISA detection antibodies set BRR batch 3.
Sub-Nanogram Detection of RDX Explosive by Monoclonal Antibodies.
Ulaeto, David O; Hutchinson, Alistair P; Nicklin, Stephen
2015-08-01
Polyclonal and monoclonal antibodies were raised to protein carrier molecules haptenized with RDX, a major component of many plastic explosives including Semtex. Sera from immunized mice detected RDX protein conjugates in standard ELISA. Clonally purified monoclonal antibodies had detection limits in the sub-ng/mL range for underivatized RDX in competition ELISA. The monoclonal antibodies are not dependent on the presence of taggants added during the manufacturing process, and are likely to have utility in the detection of any explosive containing RDX, or RDX contamination of environmental sites.
Sub-Nanogram Detection of RDX Explosive by Monoclonal Antibodies
Hutchinson, Alistair P.; Nicklin, Stephen
2015-01-01
Polyclonal and monoclonal antibodies were raised to protein carrier molecules haptenized with RDX, a major component of many plastic explosives including Semtex. Sera from immunized mice detected RDX protein conjugates in standard ELISA. Clonally purified monoclonal antibodies had detection limits in the sub-ng/mL range for underivatized RDX in competition ELISA. The monoclonal antibodies are not dependent on the presence of taggants added during the manufacturing process, and are likely to have utility in the detection of any explosive containing RDX, or RDX contamination of environmental sites. PMID:26252765
Detection of antitrichomonal antibodies in sera and cervical secretions in trichomoniasis.
Romia, S A; Othman, T A
1991-08-01
The AT, IFAT and ELISA were used to detect circulating and cervical antitrichomonal antibodies, using living and dead whole parasite or soluble protein extract as antigens respectively, in 93 women with proven trichomoniasis and 25 healthy women as controls. The results revealed that the IFA test is the most sensitive one for detecting serum (92.5%) and cervical (87.1%) antibodies. Circulating IgM rather than IgG appeared to be the antibody class involved in infected women, while cervical secretions showed a significant high concentrations of IgA, IgG and IgM. On the other hand, no IgE was detected neither in sera nor in secretions. The detection of antitrichomonal antibodies in controls, with no demonstrable trichomonal infection, may be accounted for previous infection.
Forsey, T; Darougar, S
1980-02-01
A rapid indirect micro-immunofluorescence test capable of detecting and differentiating type-specific antibodies to herpes simplex virus is described. The test proved highly sensitive and, in 80 patients with active herpes ocular infection, antibody was detected in 94%. No anti-herpes antibody was detected in a control group of 20 patients with adenovirus infections. Testing of animal sera prepared against herpes simplex virus types 1 and 2 and of human sera from cases of ocular and genital herpes infections showed that the test can differentiate antibodies to the infecting serotypes. Specimens of whole blood, taken by fingerprick, and eye secretions, both collected on cellulose sponges, could be tested by indirect micro-immunofluorescence. Anti-herpes IgG, IgM, and IgA can also be detected.
Detection of Antibodies in Blood Plasma Using Bioluminescent Sensor Proteins and a Smartphone.
Arts, Remco; den Hartog, Ilona; Zijlema, Stefan E; Thijssen, Vito; van der Beelen, Stan H E; Merkx, Maarten
2016-04-19
Antibody detection is of fundamental importance in many diagnostic and bioanalytical assays, yet current detection techniques tend to be laborious and/or expensive. We present a new sensor platform (LUMABS) based on bioluminescence resonance energy transfer (BRET) that allows detection of antibodies directly in solution using a smartphone as the sole piece of equipment. LUMABS are single-protein sensors that consist of the blue-light emitting luciferase NanoLuc connected via a semiflexible linker to the green fluorescent acceptor protein mNeonGreen, which are kept close together using helper domains. Binding of an antibody to epitope sequences flanking the linker disrupts the interaction between the helper domains, resulting in a large decrease in BRET efficiency. The resulting change in color of the emitted light from green-blue to blue can be detected directly in blood plasma, even at picomolar concentrations of antibody. Moreover, the modular architecture of LUMABS allows changing of target specificity by simple exchange of epitope sequences, as demonstrated here for antibodies against HIV1-p17, hemagglutinin (HA), and dengue virus type I. The combination of sensitive ratiometric bioluminescent detection and the intrinsic modularity of the LUMABS design provides an attractive generic platform for point-of-care antibody detection that avoids the complex liquid handling steps associated with conventional immunoassays.
Konrad, Anna; Ashok, Nikhil; Pontén, Fredrik; Hober, Sophia; Asplund, Anna
2013-01-01
Antibody-based protein profiling on a global scale using immunohistochemistry constitutes an emerging strategy for mapping of the human proteome, which is crucial for an increased understanding of biological processes in the cell. Immunohistochemistry is often performed indirectly using secondary antibodies for detection, with the benefit of signal amplification. Direct immunohistochemistry instead brings the advantage of multiplexing; however, it requires labeling of the primary antibody. Many antibody-labeling kits do not specifically target IgG and may therefore cause labeling of stabilizing proteins present in the antibody solution. A new conjugation method has been developed that utilizes a modified Z-domain of protein A (ZBPA) to specifically target the Fc part of antibodies. The aim of the present study was to compare the ZBPA conjugation method and a commercially available labeling kit, Lightning-Link, for in situ protein detection. Fourteen antibodies were biotinylated with each method and stained using immunohistochemistry. For all antibodies tested, ZBPA biotinylation resulted in distinct immunoreactivity without off-target staining, regardless of the presence of stabilizing proteins in the buffer, whereas the majority of the Lightning-Link biotinylated antibodies displayed a characteristic pattern of nonspecific staining. We conclude that biotinylated ZBPA domain provides a stringent method for antibody biotinylation, advantageous for in situ protein detection in tissues. PMID:23920108
Vora, N.M.; Orciari, L.A.; Niezgoda, M.; Selvaggi, G.; Stosor, V.; Lyon, G.M.; Wallace, R.M.; Gabel, J.; Stanek, D.R.; Jenkins, P.; Shiferaw, M.; Yager, P.; Jackson, F.; Hanlon, C.A.; Damon, I.; Blanton, J.D.; Recuenco, S.; Franka, R.
2015-01-01
Background The rabies virus causes a fatal encephalitis and can be transmitted through organ transplantation. In 2013, a man developed rabies 18 months after receiving a kidney from a donor with rabies, who was not known to have been infected when the organs were procured. Three additional persons who received organs from the same donor (liver, kidney, heart), all of whom were not vaccinated for rabies before transplantation, received rabies post-exposure prophylaxis (PEP) with rabies immune globulin and 5 doses of rabies vaccine as soon as the diagnosis of rabies was made in the donor (18 months after their transplant surgeries). We describe their clinical management. Methods As the 3 recipients were all on immunosuppressive medications, post-vaccination serologic testing was performed using the rapid fluorescent focus inhibition test to measure rabies virus neutralizing antibodies (RVNAs). An acceptable antibody response to administration of rabies vaccine was defined as detection of RVNAs at a concentration ≥0.1 IU/mL from a serum specimen collected ≥7 days after the fifth vaccine dose. Results All 3 recipients demonstrated an acceptable antibody response despite their immunosuppressed states. More than 36 months have passed since their transplant surgeries, and all 3 recipients have no evidence of rabies. Conclusions The survival of 3 previously unvaccinated recipients of solid organs from a donor with rabies is unexpected. Although the precise factors that led to their survival remain unclear, our data suggest that PEP can possibly enhance transplant safety in settings in which donors are retrospectively diagnosed with rabies. PMID:25851103
Vora, N M; Orciari, L A; Niezgoda, M; Selvaggi, G; Stosor, V; Lyon, G M; Wallace, R M; Gabel, J; Stanek, D R; Jenkins, P; Shiferaw, M; Yager, P; Jackson, F; Hanlon, C A; Damon, I; Blanton, J D; Recuenco, S; Franka, R
2015-06-01
The rabies virus causes a fatal encephalitis and can be transmitted through organ transplantation. In 2013, a man developed rabies 18 months after receiving a kidney from a donor with rabies, who was not known to have been infected when the organs were procured. Three additional persons who received organs from the same donor (liver, kidney, heart), all of whom were not vaccinated for rabies before transplantation, received rabies post-exposure prophylaxis (PEP) with rabies immune globulin and 5 doses of rabies vaccine as soon as the diagnosis of rabies was made in the donor (18 months after their transplant surgeries). We describe their clinical management. As the 3 recipients were all on immunosuppressive medications, post-vaccination serologic testing was performed using the rapid fluorescent focus inhibition test to measure rabies virus neutralizing antibodies (RVNAs). An acceptable antibody response to administration of rabies vaccine was defined as detection of RVNAs at a concentration ≥0.1 IU/mL from a serum specimen collected ≥7 days after the fifth vaccine dose. All 3 recipients demonstrated an acceptable antibody response despite their immunosuppressed states. More than 36 months have passed since their transplant surgeries, and all 3 recipients have no evidence of rabies. The survival of 3 previously unvaccinated recipients of solid organs from a donor with rabies is unexpected. Although the precise factors that led to their survival remain unclear, our data suggest that PEP can possibly enhance transplant safety in settings in which donors are retrospectively diagnosed with rabies. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Comparison of Gluten Extraction Protocols Assessed by LC-MS/MS Analysis.
Fallahbaghery, Azadeh; Zou, Wei; Byrne, Keren; Howitt, Crispin A; Colgrave, Michelle L
2017-04-05
The efficiency of gluten extraction is of critical importance to the results derived from any analytical method for gluten detection and quantitation, whether it employs reagent-based technology (antibodies) or analytical instrumentation (mass spectrometry). If the target proteins are not efficiently extracted, the end result will be an under-estimation in the gluten content posing a health risk to people affected by conditions such as celiac disease (CD) and nonceliac gluten sensitivity (NCGS). Five different extraction protocols were investigated using LC-MRM-MS for their ability to efficiently and reproducibly extract gluten. The rapid and simple "IPA/DTT" protocol and related "two-step" protocol were enriched for gluten proteins, 55/86% (trypsin/chymotrypsin) and 41/68% of all protein identifications, respectively, with both methods showing high reproducibility (CV < 15%). When using multistep protocols, it was critical to examine all fractions, as coextraction of proteins occurred across fractions, with significant levels of proteins existing in unexpected fractions and not all proteins within a particular gluten class behaving the same.
Mizukami, Tomoyuki; Obara, Megumi; Nishikomori, Ryuta; Kawai, Tomoki; Tahara, Yoshihiro; Sameshima, Naoki; Marutsuka, Kousuke; Nakase, Hiroshi; Kimura, Nobuhiro; Heike, Toshio; Nunoi, Hiroyuki
2012-02-01
X-linked anhidrotic ectodermal dysplasia with immunodeficiency (X-EDA-ID) is caused by hypomorphic mutations in the gene encoding nuclear factor-κB essential modulator protein (NEMO). Patients are susceptibile to diverse pathogens due to insufficient cytokine and frequently show severe chronic colitis. An 11-year-old boy with X-EDA-ID was hospitalized with autoimmune symptoms and severe chronic colitis which had been refractory to immunosuppressive drugs. Since tumor necrosis factor (TNF) α is responsible for the pathogenesis of NEMO colitis according to intestinal NEMO and additional TNFR1 knockout mice studies, and high levels of TNFα-producing mononuclear cells were detected in the patient due to the unexpected gene reversion mosaicism of NEMO, an anti-TNFα monoclonal antibody was administered to ameliorate his abdominal symptoms. Repeated administrations improved his colonoscopic findings as well as his dry skin along with a reduction of TNFα-expressing T cells. These findings suggest TNF blockade therapy is of value for refractory NEMO colitis with gene reversion.
[Drug trials in humans. Risks in the light of the London catastrophe].
Otte, A
2007-06-01
London's first-in-man drug trial with the monoclonal anti-CD28 antibody TGN1412 used for the treatment of oncological and autoimmune diseases resulted in a disaster with life-threatening adverse events in the volunteers triggered by an unexpected cytokine storm. Potential mistakes and consequences from this trial are highlighted in the general context of drug development and its risks. Risks in drug testing are not only found for high risk substances, such as TGN1412, or in the critical first-in-man phase, but can sometimes be detected only in later phases of the clinical testing, such as the phase 3 submission studies, or even after market authorization, as for example was the case in the cyclooxygenase-2-inhibitor rofecoxib (Vioxx) used for the treatment of rheumatic diseases and acute pain. Regulatory requirements to minimize risks in drug trials, however, have improved substantially over the last decades. Moreover, in light of the London incident these are being continuously modified with great diligence.
A New Intrusion Detection Method Based on Antibody Concentration
NASA Astrophysics Data System (ADS)
Zeng, Jie; Li, Tao; Li, Guiyang; Li, Haibo
Antibody is one kind of protein that fights against the harmful antigen in human immune system. In modern medical examination, the health status of a human body can be diagnosed by detecting the intrusion intensity of a specific antigen and the concentration indicator of corresponding antibody from human body’s serum. In this paper, inspired by the principle of antigen-antibody reactions, we present a New Intrusion Detection Method Based on Antibody Concentration (NIDMBAC) to reduce false alarm rate without affecting detection rate. In our proposed method, the basic definitions of self, nonself, antigen and detector in the intrusion detection domain are given. Then, according to the antigen intrusion intensity, the change of antibody number is recorded from the process of clone proliferation for detectors based on the antigen classified recognition. Finally, building upon the above works, a probabilistic calculation method for the intrusion alarm production, which is based on the correlation between the antigen intrusion intensity and the antibody concen-tration, is proposed. Our theoretical analysis and experimental results show that our proposed method has a better performance than traditional methods.
A universal DNA-based protein detection system.
Tran, Thua N N; Cui, Jinhui; Hartman, Mark R; Peng, Songming; Funabashi, Hisakage; Duan, Faping; Yang, Dayong; March, John C; Lis, John T; Cui, Haixin; Luo, Dan
2013-09-25
Protein immune detection requires secondary antibodies which must be carefully selected in order to avoid interspecies cross-reactivity, and is therefore restricted by the limited availability of primary/secondary antibody pairs. Here we present a versatile DNA-based protein detection system using a universal adapter to interface between IgG antibodies and DNA-modified reporter molecules. As a demonstration of this capability, we successfully used DNA nano-barcodes, quantum dots, and horseradish peroxidase enzyme to detect multiple proteins using our DNA-based labeling system. Our system not only eliminates secondary antibodies but also serves as a novel method platform for protein detection with modularity, high capacity, and multiplexed capability.
A Universal DNA-Based Protein Detection System
Tran, Thua N. N.; Cui, Jinhui; Hartman, Mark R.; Peng, Songming; Funabashi, Hisakage; Duan, Faping; Yang, Dayong; March, John C.; Lis, John T.; Cui, Haixin; Luo, Dan
2014-01-01
Protein immune detection requires secondary antibodies which must be carefully selected in order to avoid interspecies cross-reactivity, and is therefore restricted by the limited availability of primary/secondary antibody pairs. Here we present a versatile DNA-based protein detection system using a universal adapter to interface between IgG antibodies and DNA-modified reporter molecules. As a demonstration of this capability, we successfully used DNA nano-barcodes, quantum dots, and horseradish peroxidase enzyme to detect multiple proteins using our DNA-based labeling system. Our system not only eliminates secondary antibodies but also serves as a novel method platform for protein detection with modularity, high capacity, and multiplexed capability. PMID:23978265
Improved method for fluorescence cytometric immunohematology testing.
Roback, John D; Barclay, Sheilagh; Hillyer, Christopher D
2004-02-01
A method for accurate immunohematology testing by fluorescence cytometry (FC) was previously described. Nevertheless, the use of vacuum filtration to wash RBCs and a standard-flow cytometer for data acquisition hindered efforts to incorporate this method into an automated platform. A modified procedure was developed that used low-speed centrifugation of 96-well filter plates for RBC staining. Small-footprint benchtop capillary cytometers (PCA and PCA-96, Guava Technologies, Inc.) were used for data acquisition. Authentic clinical samples from hospitalized patients were tested for ABO group and the presence of D antigen (n = 749) as well as for the presence of RBC alloantibodies (n = 428). Challenging samples with mixed-field reactions and weak antibodies were included. Results were compared to those obtained by column agglutination technology (CAT), and discrepancies were resolved by standard tube methods. Detailed investigations of FC sensitivity and reproducibility were also performed. The modified FC method with the PCA determined the correct ABO group and D type for 98.7 percent of 520 samples, compared to 98.8 percent for CAT (p > 0.05). No-type-determined (NTD) rates were 1.2 percent for both methods. In testing for unexpected alloantibodies, FC determined the correct result for 98.6 percent of 215 samples, compared to 96.3 percent for CAT (p > 0.05). When samples were automatically acquired in the 96-well plate format with the PCA-96, 98.7 percent of 229 samples had correct ABO group and D type determined by FC, compared to 97.4 percent for CAT (p > 0.05). NTD rates were 0.9 and 2.6 percent, respectively. Antibody screens were accurate for 99.1 percent of 213 samples with the PCA-96, compared to 99.5 percent for CAT (p > 0.05). Further investigations demonstrated that FC with the PCA-96 was better than CAT at detecting weak anti-A (p < 0.0001) and alloantibodies. An improved method for FC immunohematology testing has been described. This assay was comparable in accuracy to standard CAT techniques, but had better sensitivity for detecting weak antibodies and was superior in detecting mixed-field reactions (p < 0.005). The FC method demonstrated excellent reproducibility. The compatibility of this assay with the PCA-96 capillary cytometer with plate-handling capabilities should simplify development of a completely automated platform.
Haleyur Giri Setty, Mohan Kumar; Liu, Jikun; Mahtani, Prerna; Zhang, Panhe; Du, Bingchen; Ragupathy, Viswanath; Devadas, Krishnakumar; Hewlett, Indira K
2016-06-01
Accurate detection and quantification of HIV-1 group O viruses have been challenging for currently available HIV assays. We have developed a novel time-resolved fluorescence (TRF) europium nanoparticle immunoassay for HIV-1 group O detection using a conventional microplate enzyme-linked immunosorbent assay (ELISA) and a microchip platform. We screened several antibodies for optimal reactivity with several HIV-1 group O strains and identified antibodies that can detect all the strains of HIV-1 group O that were available for testing. The antibodies were used to develop a conventional ELISA format assay and an in-house developed europium nanoparticle-based assay for sensitivity. The method was evaluated on both microwell plate and microchip platforms. We identified two specific and sensitive antibodies among the six we screened. The antibodies, C65691 and ANT-152, were able to quantify 15 and detect all 17 group O viruses, respectively, as they were broadly cross-reactive with all HIV-1 group O strains and yielded better signals compared with other antibodies. We have developed a sensitive assay that reflects the actual viral load in group O samples by using an appropriate combination of p24 antibodies that enhance group O detection and a highly sensitive TRF-based europium nanoparticle for detection. The combination of ANT-152 and C65690M in the ratio 3:1 was able to give significantly higher signals in our europium-based assay compared with using any single antibody.
Monoclonal antibodies to cyclodiene insecticides and method for detecting the same
Stanker, L.H.; Vanderlaan, M.; Watkins, B.E.
1994-08-02
Methods are described for making specific monoclonal antibodies useful for detection of cyclodienes in foods and environmental samples. Monoclonal antibodies specifically reactive with cyclodienes can detect accumulated pesticides in food, tissue or environmental samples. Extraction and preparation of organic samples for immunoassay in a polar-nonpolar reaction medium permits detection of halogenated organic ring structures at concentrations in samples. 13 figs.
Chirathaworn, Chintana; Janwitthayanan, Weena; Sereemaspun, Amornpun; Lertpocasombat, Kanchalee; Rungpanich, Utane; Ekpo, Pattama; Suwancharoen, Duangjai
2014-04-01
Detection of antibody specific to Leptospira by various immunological techniques has been used for leptospirosis diagnosis. However, the sensitivity of antibody detection during the first few days after infection is low. Molecular techniques are suggested to provide earlier diagnosis than antibody detection, but a rapid and easy to perform assay for Leptospira antigen detection would provide an additional useful tool for disease diagnosis. In this study, we coupled gold nanoparticles with antibody to LipL32, a protein commonly found in pathogenic Leptospira. This coupled gold reagent was used in the immunochromatographic strip for Leptospira detection. We demonstrated that the sensitivity of Leptospira detection by this strip was 10(3) ml(-1). There was no positive result detected when strips were tested with non-pathogenic Leptospira, Staphylococcus aureus, Streptococcus group B, Acinetobacter baumannii, Escherichia coli, Salmonella typhi, Klebsiella pneumoniae, Enterococcus faecalis or Enterococcus faecium. These data suggest that gold nanoparticles coupled with antibody to LipL32 could be used for Leptospira detection by a rapid test based on an immunochromatographic technique.
Animal Diseases Caused by Orbiviruses, Algeria
Madani, Hafsa; Casal, Jordi; Alba, Anna; Allepuz, Alberto; Cêtre-Sossah, Catherine; Hafsi, Leila; Kount-Chareb, Houria; Bouayed-Chaouach, Nadera; Saadaoui, Hassiba
2011-01-01
Antibodies against bluetongue virus were detected in cattle, sheep, goats, and camels in Algeria in 2008. Antibodies against epizootic hemorrhagic disease virus were detected in cattle, but antibodies against African horse sickness virus were not detected in horses and mules. Epizootic hemorrhagic disease in northern Africa poses a major risk for the European Union. PMID:22172371
Detecting decay fungi with antibody-based tests and immunoassays
Carol A. Clausen
2003-01-01
Early detection of wood decay can prolong the service life of wood. Antibodies are the ideal probe for detecting fungi that cause biodeterioration because they are highly specific and can quantitatively determine the fungal antigen concentration from highly complex structures, such as wood. Polyclonal antibodies recognize multiple chemical sites of the targeted...
Method for detecting pathogens attached to specific antibodies
Miles, Robin R.; Venkateswaran, Kodumudi S.; Fuller, Christopher K.
2005-01-25
The use of impedance measurements to detect the presence of pathogens attached to antibody-coated beads. In a fluidic device antibodies are immobilized on a surface of a patterned interdigitated electrode. Pathogens in a sample fluid streaming past the electrode attach to the immobilized antibodies, which produces a change in impedance between two adjacent electrodes, which impedance change is measured and used to detect the presence of a pathogen. To amplify the signal, beads coated with antibodies are introduced and the beads would stick to the pathogen causing a greater change in impedance between the two adjacent electrodes.
Impedance measurements for detecting pathogens attached to antibodies
Miles, Robin R.; Venkateswaran, Kodumudi S.; Fuller, Christopher K.
2004-12-28
The use of impedance measurements to detect the presence of pathogens attached to antibody-coated beads. In a fluidic device antibodies are immobilized on a surface of a patterned interdigitated electrode. Pathogens in a sample fluid streaming past the electrode attach to the immobilized antibodies, which produces a change in impedance between two adjacent electrodes, which impedance change is measured and used to detect the presence of a pathogen. To amplify the signal, beads coated with antibodies are introduced and the beads would stick to the pathogen causing a greater change in impedance between the two adjacent electrodes.
NASA Astrophysics Data System (ADS)
Song, Dandan; Qu, Xiaofeng; Liu, Yushen; Li, Li; Yin, Dehui; Li, Juan; Xu, Kun; Xie, Renguo; Zhai, Yue; Zhang, Huiwen; Bao, Hao; Zhao, Chao; Wang, Juan; Song, Xiuling; Song, Wenzhi
2017-03-01
Brucella spp. are facultative intracellular bacteria that cause zoonotic disease of brucellosis worldwide. Traditional methods for detection of Brucella spp. take 48-72 h that does not meet the need of rapid detection. Herein, a new rapid detection method of Brucella was developed based on polyclonal antibody-conjugating quantum dots and antibody-modified magnetic beads. First, polyclonal antibodies IgG and IgY were prepared and then the antibody conjugated with quantum dots (QDs) and immunomagnetic beads (IMB), respectively, which were activated by N-(3-dimethylaminopropyl)- N'-ethylcar-bodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS) to form probes. We used the IMB probe to separate the Brucella and labeled by the QD probe, and then detected the fluorescence intensity with a fluorescence spectrometer. The detection method takes 105 min with a limit of detection of 103 CFU/mL and ranges from 10 to 105 CFU/mL ( R 2 = 0.9983), and it can be well used in real samples.
Detection of antisalivary duct antibody from Sjögren's syndrome by an autoradiographic method.
Cummings, N A; Tarpley, T M
1978-01-01
A new technique to detect anti-salivary duct antibody (ASDA) has been developed by using autoradiographic, rather than immunofluorescent methods. The antibody activity detected by autoradiography is probably classic ASDA. Both techniques may be consecutively performed on the same tissue section without attenuation of either. Some of the potential advantages of the radiolabelling of ASDA are pointed out, and a few preliminary experiments using the labelled antibody as a marker are presented.
Comparative efficacy of antigen and antibody detection tests for human trichinellosis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ivanoska, D.; Cuperlovic, K.; Gamble, H.R.
1989-02-01
Sera collected from patients with suspected or confirmed exposure to Trichinella spiralis were tested for circulating parasite antigens and antiparasite antibodies. Using an immunoradiometric assay, excretory--secretory antigens from muscle-stage larvae of T. spiralis were detected in the sera of 47% of 62 patients with clinical trichinellosis and 13% of 39 patients without clinical signs but suspected of exposure to infected meat. In comparison, antibodies were detected using an indirect immunofluorescent test in the circulation of 100% of the 62 patients with clinical trichinellosis and 46% of the 39 patients with suspected exposure. The presence of antibodies specific to excretory-secretory productsmore » of T. spiralis muscle larvae was confirmed in the majority of the samples tested by a monoclonal antibody-based competitive inhibition assay. These results indicate that antibody detection is a more sensitive diagnostic method for human trichinellosis, but that antigen detection might be a useful confirmatory test because it is a direct demonstration of parasite products in the circulation.« less
Avian influenza virus antibodies in Pacific Coast Red Knots (Calidris canutus rufa)
Johnson, James A.; DeCicco, Lucas H.; Ruthrauff, Daniel R.; Krauss, Scott; Hall, Jeffrey S.
2014-01-01
Prevalence of avian influenza virus (AIV) antibodies in the western Atlantic subspecies of Red Knot (Calidris canutus rufa) is among the highest for any shorebird. To assess whether the frequency of detection of AIV antibodies is high for the species in general or restricted only to C. c. rufa, we sampled the northeastern Pacific Coast subspecies of Red Knot (Calidris canutus roselaari) breeding in northwestern Alaska. Antibodies were detected in 90% of adults and none of the chicks sampled. Viral shedding was not detected in adults or chicks. These results suggest a predisposition of Red Knots to AIV infection. High antibody titers to subtypes H3 and H4 were detected, whereas low to intermediate antibody levels were found for subtypes H10 and H11. These four subtypes have previously been detected in shorebirds at Delaware Bay (at the border of New Jersey and Delaware) and in waterfowl along the Pacific Coast of North America.
Turner, E S; Pruzansky, J J; Patterson, R; Zeiss, C R; Roberts, M
1980-02-01
Utilizing trimellityl-erythrocytes (TM-E), antibodies were detected in sera of seven workers with trimellitic anhydride (TMA) induced airway syndromes by direct haemagglutination, indirect haemagglutination with anti-human IgG, IgA or IgM or by haemolysis. Detectable levels of antibody were obtained with all three methods. The most sensitive technique was indirect haemagglutination using anti-IgG. When added as an inhibitor, TM-human serum albumin produced a 10- to 800-fold reduction in titres. TM-ovalbumin of similar epitope density was less inhibitory and sodium trimellitate the least inhibitory on a molar basis. All of the assays using haptenized human red cells were also capable of detecting anti-TM antibodies in Rhesus monkeys whose airways had been exposed to TMA. These assays are useful for detecting anti-TM antibodies and may also be adapted to demonstrate antibodies induced against other inhaled haptens in sera of environmentally exposed individuals or in animal models of such exposure.
Lee, SangWook; Kim, Soyoun; Malm, Johan; Jeong, Ok Chan; Lilja, Hans; Laurell, Thomas
2014-01-01
Enriching the surface density of immobilized capture antibodies enhances the detection signal of antibody sandwich microarrays. In this study, we improved the detection sensitivity of our previously developed P-Si (porous silicon) antibody microarray by optimizing concentrations of the capturing antibody. We investigated immunoassays using a P-Si microarray at three different capture antibody (PSA - prostate specific antigen) concentrations, analyzing the influence of the antibody density on the assay detection sensitivity. The LOD (limit of detection) for PSA was 2.5ngmL−1, 80pgmL−1, and 800fgmL−1 when arraying the PSA antibody, H117 at the concentration 15µgmL−1, 35µgmL−1 and 154µgmL−1, respectively. We further investigated PSA spiked into human female serum in the range of 800fgmL−1 to 500ngmL−1. The microarray showed a LOD of 800fgmL−1 and a dynamic range of 800 fgmL−1 to 80ngmL−1 in serum spiked samples. PMID:24016590
Method for detection of antibodies for metallic elements
Barrick, C.W.; Clarke, S.M.; Nordin, C.W.
1993-11-30
An apparatus and method for detecting antibodies specific to non-protein antigens. The apparatus is an immunological plate containing a plurality of plastic projections coated with a non-protein material. Assays utilizing the plate are capable of stabilizing the non-protein antigens with detection levels for antibodies specific to the antigens on a nanogram level. A screening assay with the apparatus allows for early detection of exposure to non-protein materials. Specifically metallic elements are detected. 10 figures.
[Development and application of CK-MB specific monoclonal antibodies].
Chen, Zimin; Zhou, Guoliang; Xu, Weiling; Zheng, Xiaohong; Tong, Xunzhang; Ke, Qishen; Song, Liuwei; Ge, Shengxiang
2017-01-25
The aim of this study is to develop creatine kinase isoenzyme MB (CK-MB) specific monoclonal antibodies (mAb), and characterize the monoclonal antibody and further development of quantitative detection assay for CK-MB. The BALB/c mice were immunized with purchased CK-MB antigen, then monoclonal antibodies were prepared according to conventional hybridoma technique and screened by indirect and capture ELISA method. To identify the epitopes and evaluate the classification, purchased creatine kinase isoenzyme MB (CK-MM/BB/MB) antigen was used to identify the epitopes, with immunoblotting and synthetic CK-MM and CK-BB in different linear epitope. A double antibody sandwich ELISA was applied to screen the mAb pairs for CK-MB detection, and the quantitative detection assay for CK-MB was developed. We used 74 cases of clinical specimens for comparison of our assay with Roche's CK-MB assay. We successfully developed 22 strains of hybridoms against CK-MB, these mAbs can be divided into linear, partial conformational CK-MB, CK-MM or CK-BB cross monoclonal antibody and CK-MB specific reaction with partial conformational monoclonal antibody, and CK-MB quantitative detection assay was developed by using partial conformational monoclonal antibody. The correlation coefficient factor r of our reagent and Roche's was 0.930 9. This study established a screening method for CK-MB partial conformational specific monoclonal antibody, and these monoclonal antibodies were analyzed and an established quantitative detection assay was developed. The new assay had a high concordance with Roche's.
Dou, Baoting; Yang, Jianmei; Shi, Kai; Yuan, Ruo; Xiang, Yun
2016-09-15
We describe here the development of a sensitive and convenient electronic sensor for the detection of antibodies in human serums. The sensor is constructed by self-assembly formation of a mixed monolayer containing the small molecule epitope conjugated double stranded DNA probes on gold electrode. The target antibody binds the epitope on the dsDNA probe and lowers the melting temperature of the duplex, which facilitates the displacement of the antibody-linked strand of the duplex probe by an invading methylene blue-tagged single stranded DNA (MB-ssDNA) through the strand displacement reaction and leads to the capture of many MB-ssDNA on the sensor surface. Subsequent electrochemical oxidation of the methylene blue labels results in amplified current response for sensitive monitoring of the antibodies. The antibody assay conditions are optimized and the sensor exhibits a linear range between 1.0 and 25.0nM with a detection limit of 0.67nM for the target antibody. The sensor is also selective and can be employed to detect the target antibodies in human serum samples. With the advantages of using small molecule epitope as the antibody recognition element over traditional antigen, the versatile manipulability of the DNA probes and the unique properties of the electrochemical transduction technique, the developed sensor thus hold great potential for simple and sensitive detection of different antibodies and other proteins in real samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Granberg, C; Mansikka, A; Lehtonen, O P; Kujari, H; Grönfors, R; Nurmi, H; Räihä, I; Ståhlberg, M R; Leino, R
1993-01-01
We evaluated the performance of new enzyme immunoassay (EIA) kits (Pyloriset; Orion Corporation, Orion Diagnostica, Espoo, Finland) for the detection of immunoglobulin G (IgG) and IgA antibodies to Helicobacter pylori in serum. Serum samples from 195 patients with upper abdominal complaints were collected. Biopsy specimens of the gastric mucosae were taken for histological analysis and bacterial culture. The sensitivity, specificity, and positive and negative predictive values, and efficacy of the Pyloriset EIA-G in detecting IgG antibodies to H. pylori were 92, 84, 88, 90, and 89%, respectively, when compared with those of the reference methods used. The corresponding data for detection of IgA antibodies were 80, 89, 89, 79, and 84%, respectively. The overall prevalence of defined H. pylori positivity was 54%. Moreover, the antibody tests showed a very good correlation with the biopsy findings. IgG antibodies were found in 93% of sera from patients with documented gastritis and H. pylori positivity, whereas only 4% of the sera from patients with documented gastritis and H. pylori-negative patients was positive. The results obtained for IgA antibodies were 81 and 6%, respectively. We conclude that the Pyloriset EIA-G, the test for IgG antibodies, is a good and reliable test for the detection of antibodies to H. pylori and as an indication of H. pylori infection. The determination of IgA antibodies may be used as a test that complements the IgG antibody assay. PMID:8314985
Doppler, Kathrin; Appeltshauser, Luise; Krämer, Heidrun H; Ng, Judy King Man; Meinl, Edgar; Villmann, Carmen; Brophy, Peter; Dib-Hajj, Sulayman D; Waxman, Stephen G; Weishaupt, Andreas; Sommer, Claudia
2015-01-01
Multifocal motor neuropathy is an immune mediated disease presenting with multifocal muscle weakness and conduction block. IgM auto-antibodies against the ganglioside GM1 are detectable in about 50% of the patients. Auto-antibodies against the paranodal proteins contactin-1 and neurofascin-155 and the nodal protein neurofascin-186 have been detected in subgroups of patients with chronic inflammatory demyelinating polyneuropathy. Recently, auto-antibodies against neurofascin-186 and gliomedin were described in more than 60% of patients with multifocal motor neuropathy. In the current study, we aimed to validate this finding, using a combination of different assays for auto-antibody detection. In addition we intended to detect further auto-antibodies against paranodal proteins, specifically contactin-1 and neurofascin-155 in multifocal motor neuropathy patients' sera. We analyzed sera of 33 patients with well-characterized multifocal motor neuropathy for IgM or IgG anti-contactin-1, anti-neurofascin-155 or -186 antibodies using enzyme-linked immunosorbent assay, binding assays with transfected human embryonic kidney 293 cells and murine teased fibers. We did not detect any IgM or IgG auto-antibodies against contactin-1, neurofascin-155 or -186 in any of our multifocal motor neuropathy patients. We conclude that auto-antibodies against contactin-1, neurofascin-155 and -186 do not play a relevant role in the pathogenesis in this cohort with multifocal motor neuropathy.
Schmidt, Robert L; Mock, Donald M; Franco, Robert S; Cohen, Robert M; North, Anne K; Cancelas, José A; Geisen, Christof; Strauss, Ronald G; Vlaar, Alexander P; Nalbant, Demet; Widness, John A
2017-06-01
Biotin-labeled red blood cells (BioRBCs) are used for in vivo kinetic studies. Because BioRBC dosing occasionally induces antibodies, a sensitive and specific anti-BioRBC detection assay is needed. Aims were to 1) develop a gel card assay to evaluate existing, naturally occurring and BioRBC-induced plasma antibodies, 2) compare gel card and tube agglutination detection results, and 3) test for a relationship of antibody induction and BioRBC dose. Reagent BioRBCs were prepared using sulfo-NHS biotin ranging from densities 18 (BioRBC-18) to 1458 (BioRBC-1458) µg/mL RBCs. Among BioRBC-exposed subjects, gel card and tube agglutination results were concordant in 21 of 22 adults and all 19 infant plasma samples. Gel card antibody detection sensitivity was more than 10-fold greater than tube agglutination. Twelve to 16 weeks after BioRBC exposure, induced anti-antibodies were detected by gel card in three of 26 adults (12%) at reagent densities BioRBC-256 or less, but in none of 41 infants. Importantly, induced anti-BioRBC antibodies were associated with higher BioRBC dose (p = 0.008); no antibodies were detected in 18 subjects who received BioRBC doses less than or equal to BioRBC-18. For noninduced BioRBC antibodies, six of 1125 naïve adults (0.3%) and none of 46 naïve infants demonstrated existing anti-BioRBC antibodies using reagent BioRBC-140 or -162. Existing anti-BioRBCs were all neutralized by biotin compounds, while induced antibodies were not. The gel card assay is more sensitive than the tube agglutination assay. We recommend reagent BioRBC-256 for identifying anti-BioRBCs. Use of a low total RBC biotin label dose (≤ BioRBC-18) may minimize antibody induction. © 2017 AABB.
Carbamylated albumin is one of the target antigens of anti-carbamylated protein antibodies.
Nakabo, Shuichiro; Hashimoto, Motomu; Ito, Shinji; Furu, Moritoshi; Ito, Hiromu; Fujii, Takao; Yoshifuji, Hajime; Imura, Yoshitaka; Nakashima, Ran; Murakami, Kosaku; Kuramoto, Nobuo; Tanaka, Masao; Satoh, Junko; Ishigami, Akihito; Morita, Satoshi; Mimori, Tsuneyo; Ohmura, Koichiro
2017-07-01
Anti-carbamylated protein (anti-CarP) antibodies are detected in RA patients. Fetal calf serum is used as an antigen source in anti-CarP ELISA, and the precise target antigens have not been found. We aimed to identify the target antigens of anti-CarP antibodies. Western blotting of anti-CarP antibodies was conducted. Anti-carbamylated human albumin (CarALB) antibody was detected by in-house ELISA for 493 RA patients and 144 healthy controls (HCs). An inhibition ELISA of anti-CarP antibodies by CarALB and citrullinated albumin (citALB) was performed using eight RA patients' sera. Serum CarALB was detected by liquid chromatography-tandem mass spectroscopy (LC/MS/MS), and the serum MPO concentration was measured by ELISA. We focused on carbamylated albumin because it corresponded to the size of the thickest band detected by western blotting of anti-CarP antibodies. Anti-CarALB antibody was detected in 31.4% of RA patients, and the correlation of the titres between anti-CarALB and anti-CarP was much closer than that between anti-citALB and anti-CCP antibodies (ρ = 0.59 and ρ = 0.16, respectively). The inhibition ELISA showed that anti-CarP antibodies were inhibited by CarALB, but not by citALB. CarALB was detected in sera from RA patients by LC/MS/MS. The serum MPO concentration was correlated with disease activity and was higher in RA patients with anti-CarALB antibody than in those without. We found that carbamylated albumin is a novel target antigen of anti-CarP antibodies, and it is the first reported target antigen that has not been reported as the target of ACPA. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com
The Detection of Protein via ZnO Resonant Raman Scattering Signal
NASA Astrophysics Data System (ADS)
Shan, Guiye; Yang, Guoliang; Wang, Shuang; Liu, Yichun
2008-03-01
Detecting protein with high sensitivity and specificity is essential for disease diagnostics, drug screening and other application. Semiconductor nanoparticles show better properties than organic dye molecules when used as markers for optical measurements. We used ZnO nanoparticles as markers for detecting protein in resonant Raman scattering measurements. The highly sensitive detection of proteins was achieved by an antibody-based sandwich assay. A probe for the target protein was constructed by binding the ZnO/Au nanoparticles to a primary antibody by eletrostatic interaction between Au and the antibody. A secondary antibody, which could be specifically recognized by target protein, was attached to a solid surface. The ZnO/Au-antibody probe could specifically recognize and bind to the complex of the target protein and secondary antibody. Our measurements using the resonant Raman scattering signal of ZnO nanoparticles showed good selectivity and sensitivity for the target protein.
Detection of anti-Yta antibodies using a sensitive and specific enzyme-linked immunosorbent assay.
Geen, J; Hullin, D A; Hogg, S I
1999-01-01
A specific, sensitive and semi-quantitative enzyme-linked immunosorbent assay (ELISA) is described to detect anti-Yta antibodies in human serum. Recombinant acetylcholinesterase (AChE E.C.3.1.1.7) was employed as the coating antigen in the microtitre plate and horseradish peroxidase (HRP)-conjugated specific antibody (IgG) was used as the secondary antibody. The method developed showed excellent sensitivity, detecting a titre > 1 in 600,000 (3.5 ng/mL mouse IgG protein) for mouse monoclonal (mMAb) anti-AChE antibody. No cross-reaction was seen with other common blood group antibodies, confirming the specificity of the method. The recombinant antigen's AChE phenotype was confirmed as Yta, as no reaction was detected with anti-Ytb-positive sera. The ELISA method correlated closely with the established serological grading system used routinely in blood transfusion laboratories.
Ács, Balázs; Kulka, Janina; Kovács, Kristóf Attila; Teleki, Ivett; Tőkés, Anna-Mária; Meczker, Ágnes; Győrffy, Balázs; Madaras, Lilla; Krenács, Tibor; Szász, Attila Marcell
2017-07-01
Although several antibodies are available for immunohistochemical detection of Ki-67, even the most commonly used MIB-1 has not been validated yet. Our aim was to compare 5 commercially available antibodies for detection of Ki-67 in terms of agreement and their ability in predicting prognosis of breast cancer. Tissue microarrays were constructed from 378 breast cancer patients' representative formalin-fixed, paraffin-embedded tumor blocks. Five antibodies were used to detect Ki-67 expression: MIB-1 using chromogenic detection and immunofluorescent-labeled MIB-1, SP-6, 30-9, poly, and B56. Semiquantitative assessment was performed by 2 pathologists independently on digitized slides. To compare the 5 antibodies, intraclass correlation and concordance correlation coefficient were used. All the antibodies but immunofluorescent-labeled MIB-1 (at 20% and 30% thresholds, P=.993 and P=.342, respectively) and B56 (at 30% threshold, P=.288) separated high- and low-risk patient groups. However, there were a significant difference (P values for all comparisons≤.005) and a moderate concordance (intraclass correlation, 0.645) between their Ki-67 labeling index scores. The highest concordance was found between MIB-1 and poly (concordance correlation coefficient=0.785) antibodies. None of the antibodies except Ki-67 labeling index as detected by poly (P=.031) at 20% threshold and lymph node status (P<.001) were significantly linked to disease-free survival in multivariate analysis. At 30% threshold, this was reduced to lymph node status (P<.001) alone. Our results showed that there are considerable differences between the different Ki-67 antibodies in their capacity to detect proliferating tumor cells and to separate low- and high-risk breast cancer patient groups. Copyright © 2017 Elsevier Inc. All rights reserved.
Nogueira, J M; Garcia-de-Lomas, J; Buesa, F J; Prat, J; Mir, A; Camarena, J J
1985-10-01
Candida albicans colonization induces antibodies, which must be taken into account in the serological diagnosis of candidiasis. In order to determine the degree of this effect, an experimental study in rabbits free of specific anti-Candida antibodies by cutaneous and digestive inoculation has been carried out. The evolution of humoral response was studied over 8 weeks by indirect immunofluorescence (IIF), direct agglutination (DA), counterimmunoelectrophoresis (CIE) and double diffusion (DD). The cutaneous colonization detectable by culture was maintained until the second week in 70% of the animals and the presence of antibodies detectable by IIF and DA was observed after the 2nd week. The highest antibody titre by IFF and DA was 1/64, and was reached in the 5th week, with a tendency to drop in the following weeks. Precipitins were only detected by CIE in 15% of the animals in the 7th week. Elimination of yeast in stools continued only in 20% of the animals in the 2nd week of the experiment. Antibodies were detected by IIF and DA after the 2nd week, with the highest titres detectable by IFF in the 5th week. Precipitant antibodies detectable by CIE appeared in 15% of the animals in the 8th week.
Clavarino, Giovanna; Gauthier, Arnaud; Hellmark, Thomas; Carron, Pierre-Louis; Giovannini, Diane; Colliard, Sophie; Dragon-Durey, Marie-Agnès; Segelmark, Mårten; Cesbron, Jean-Yves; Dumestre-Pérard, Chantal
2018-04-12
Detection of circulating anti-GBM antibodies has a key role for the diagnosis of Goodpasture syndrome but immunoassays using purified or recombinant alpha3(IV)NC1 as antigen do not recognize all anti-GBM antibodies. We show that anti-GBM antibodies directed against epitopes in their native conformation or cryptic epitopes are detected by indirect immunofluorescence. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Detecting Lyme disease using antibody-functionalized carbon nanotubes
NASA Astrophysics Data System (ADS)
Dailey, Jennifer; Lerner, Mitchell; Goldsmith, Brett; Brisson, Dustin; Johnson, A. T. Charlie
2011-03-01
We combine antibodies for Lyme flagellar protein with carbon nanotube transistors to create an electronic sensor capable of definitive detection of Lyme disease. Over 35,000 cases of Lyme disease are reported in the United States each year, of which more than 23 percent are originally misdiagnosed. Rational design of the coupling of the biological system to the electronic system gives us a flexible sensor platform which we can apply to several biological systems. By coupling these antibodies to carbon nanotubes in particular, we allow for fast, sensitive, highly selective, electronic detection. Unlike antibody or biomarker detection, bacterial protein detection leads to positive identification of both early and late stage bacterial infections, and is easily expandable to environmental monitoring.
Monstad, S E; Storstein, A; Dørum, A; Knudsen, A; Lønning, P E; Salvesen, H B; Aarseth, J H; Vedeler, C A
2006-04-01
Onconeural antibodies are found in patients with cancer and are associated with paraneoplastic neurological syndromes (PNS). The objective of the present study was to assess the frequency of Yo antibodies in ovarian and breast cancer using a sensitive immunoprecipitation technique, and to look for any association of Yo antibodies with neurological symptoms and prognostic factors. A multiwell adapted fluid-phase immunoassay using radiolabelled recombinant cerebellar degeneration related protein (cdr2), produced by coupled in vitro transcription/translation was used for the detection of Yo antibodies. This technique combines high specificity and sensitivity with high sample analysing capacity for the antibody in question. Sera or EDTA-blood from 810 ovarian (n = 557) and breast cancer (n = 253) patients were analysed for Yo antibodies by immunoprecipitation, as well as immunofluorescence and immune blots. Two hundred healthy blood donors and sera from 17 patients with paraneoplastic cerebellar degeneration and Yo antibodies served as controls. Immunoprecipitation was more sensitive in detecting Yo antibodies than immunofluorescence and immune blots. The prevalence of Yo antibodies was 13/557 (2.3%) in ovarian cancer and 4/253 (1.6%) in breast cancer using immunoprecipitation. Yo antibodies were not correlated with specific histological subgroups. The Yo index of ovarian cancer patients in FIGO stage IV was higher compared to FIGO stage I-III. The prevalence of Yo antibodies was 3 times higher in patients with stage III breast cancer than in stage I and II. Only 2/17 (11.8%) patients with Yo antibodies detected during the screen of 810 cancer patients had PNS. The results show that the prevalence of Yo antibodies is low in ovarian and breast cancer. Yo antibodies may be associated with advanced cancer, but less often with PNS.
Porcelijn, Leendert; Huiskes, Elly; Comijs-van Osselen, Ilona; Chhatta, Aniska; Rathore, Vipul; Meyers, Matthew; de Haas, Masja
2014-06-01
The performance of a newly developed Luminex bead-based platelet (PLT) antibody detection method (PAKLx) was compared with the monoclonal antibody immobilization of PLT antigens (MAIPA) assay and the LifeScreen Deluxe Luminex bead-based HLA Class I antibody detection method (LMX). Six sera containing anti-human PLT antigen (HPA)-1a (n=2), HPA-1b, HPA-2b, HPA-3a, or HPA-5b were tested in titration. A total of 194 sera, including HPA-1a, -1b, -2a, -2b, -3a, -5a, and -5b antibodies with or without HLA antibodies (n=63); glycoprotein (GP) IV antibodies (n=1); PLT autoantibodies (n=3); HLA antibodies (n=45); and samples with no PLT-reactive antibodies (n=82), were tested in both assays. Comparable levels of sensitivity were obtained for the MAIPA and PAKLx. The PAKLx showed four (6%) false-negative results in 67 sera with HPA or GP-reactive antibodies: anti-HPA-3a (n=1) or anti-HPA-5b (n=3). The PAKLx showed in 10 of the total 194 samples (5%) the presence of antibodies not detected by the MAIPA. This concerned broadly GP-reactive antibodies (n=7), anti-GPIIb/IIIa combined with anti-HPA-3a (n=1), anti-HPA-1a (borderline, n=1), and anti-GPIV (n=1). Testing 175 sera for anti-HLA Class I antibodies in the PAKLx and LMX showed four discrepant results: PAKLx negative and LMX positive, n=3 and n=1, respectively. For the vast majority of the specimens tested (93%) the results of the PAKLx were in concordance with the MAIPA. The PAKLx is a fast, easy to perform, and sensitive PLT antibody screening method. © 2013 AABB.
Cytoplasmic and nuclear localization of cadherin in honey bee (Apis mellifera L.) gonads.
Florecki, Mônica M; Hartfelder, Klaus
2011-01-01
Cadherins are crucial molecules mediating cell-cell interactions between somatic and germline cells in insect and mammalian male and female gonads. We analysed the presence and localization of cadherins in ovaries of honeybee queens and in testes of drones. Transcripts representing two classical cadherins, E-cadherin (shotgun) and N-cadherin, as well as three protocadherins (Starry night, Fat and Fat-like) were detected in gonads of both sexes. Pan-cadherin antibodies, which most probably detect a honeybee N-cadherin, were used in immunolocalization analyses. In the germarium of ovarioles, cadherin-IR (cadherin immunoreactivity) was evidenced as homogeneously distributed in the cytoplasm and as nuclear foci, in both germline and somatic cells. It was also detected in polyfusomes and ring canals. In testiolar tubules, cadherin-IR showed a cytoplasmic and nuclear distributon alike in ovaries. The unexpected nuclear localization and cytoplasmic distribution in ovaries and testes were corroborated by immunogold electron microscopy, which revealed cadherin aggregates associated with electron-dense nuclear structures. With respect to cadherin localization, the honeybee differs from Drosophila, the model for gametogenesis in insects, raising the question as to how differences among solitary and social species may be built into and generated from the general architecture of polytrophic meroistic ovaries. It also indicates the possibility of divergent roles for cadherin in the functional architecture of insect gonads, in general, especially in taxa with high reproductive output.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thakur, Madhukar L.
1990-01-01
The invention discloses improved reagents containing antibodies against stage specific embryonic antigen-1 antibodies and improved methods for detection of occult abscess and inflammation using the improved reagents.
Liu, Jikun; Mahtani, Prerna; Zhang, Panhe; Du, Bingchen; Ragupathy, Viswanath; Devadas, Krishnakumar
2016-01-01
Abstract Accurate detection and quantification of HIV-1 group O viruses have been challenging for currently available HIV assays. We have developed a novel time-resolved fluorescence (TRF) europium nanoparticle immunoassay for HIV-1 group O detection using a conventional microplate enzyme-linked immunosorbent assay (ELISA) and a microchip platform. We screened several antibodies for optimal reactivity with several HIV-1 group O strains and identified antibodies that can detect all the strains of HIV-1 group O that were available for testing. The antibodies were used to develop a conventional ELISA format assay and an in-house developed europium nanoparticle-based assay for sensitivity. The method was evaluated on both microwell plate and microchip platforms. We identified two specific and sensitive antibodies among the six we screened. The antibodies, C65691 and ANT-152, were able to quantify 15 and detect all 17 group O viruses, respectively, as they were broadly cross-reactive with all HIV-1 group O strains and yielded better signals compared with other antibodies. We have developed a sensitive assay that reflects the actual viral load in group O samples by using an appropriate combination of p24 antibodies that enhance group O detection and a highly sensitive TRF-based europium nanoparticle for detection. The combination of ANT-152 and C65690M in the ratio 3:1 was able to give significantly higher signals in our europium-based assay compared with using any single antibody. PMID:26978478
Eliciting an antibody response against a recombinant TSH containing fusion protein.
Mard-Soltani, Maysam; Rasaee, Mohamad Javad; Sheikhi, AbdolKarim; Hedayati, Mehdi
2017-01-01
Designing novel antigens to rise specific antibodies for Thyroid Stimulating Hormone (TSH) detection is of great significance. A novel fusion protein consisting of the C termini sequence of TSH beta subunit and a fusion sequence was designed and produced for rabbit immunization. Thereafter, the produced antibodies were purified and characterized for TSH detection. Our results indicate that the produced antibody is capable of sensitive and specific detection of TSH with low cross reactivity. This study underscores the applicability of designed fusion protein for specific and sensitive polyclonal antibody production and the importance of selecting an amenable region of the TSH for immunization.
Diagnostics for Lassa Fever: Detecting Host Antibody Responses.
Salvato, Maria S; Lukashevich, Igor S; Medina-Moreno, Sandra; Zapata, Juan Carlos
2018-01-01
There are two types of viral diagnostics: (1) those that detect components of the pathogen (like viral RNA or proteins) and (2) those that detect host molecules that rise or fall as a consequence of pathogen infection (like anti-viral antibodies or virus-induced inflammatory cytokines). Quantitative PCR to detect Lassa RNA, and clinical chemistry to detect high liver enzymes (AST/ALT) are commonly used to diagnose Lassa fever. Here, we discuss the various types of diagnostics for Lassa fever and the urgent need for early diagnosis. We also describe a protocol for using the attenuated Lassa vaccine candidate, ML29 , as an antigen for detecting Lassa-specific antibodies. Since antibodies are developed late in the progression of Lassa fever disease, this is not an early diagnostic, but is more useful in surveillance of the population to determine the sero-prevalence of antibodies to Lassa virus (LASV ), and to define treatment options for people in close contact with a Lassa-infected person.
Complement-dependent cytotoxicity (CDC) to detect Anti-HLA antibodies: old but gold.
Saito, Patrícia Keiko; Yamakawa, Roger Haruki; Pereira, Lucieni Christina Marques da Silva; da Silva, Waldir Veríssimo; Borelli, Sueli Donizete
2014-07-01
The criterion (gold) standard to detect anti-human leukocyte antigen (HLA) antibodies is the complement-dependent cytotoxicity (CDC) assay. Recently, more sensitive methods have been used for the same purpose. This study analyzed 70 serum samples of patients with end-stage renal disease using CDC, CDC with the addition of anti-human globulin (CDC-AHG), CDC with the addition of dithiothreitol (CDC-DTT), and the recent solid-phase immunoassay (SPI; Labscreen PRA) to detect anti-HLA antibodies. Mean percent panel reactive antibodies (PRA) detected by SPI was 37.5% (±34.2) higher than the values detected by the other methods. Comparative analyses revealed significant difference between CDC and CDC-AHG, and between CDC and SPI (P < 0.0001), but not between CDC-AHG and SPI (P = 0.8026). Although the CDC-AHG method is "old," its performance to detect anti-HLA antibodies in the samples analyzed was comparable to the SPI in the evaluation of percent class I PRA. © 2014 Wiley Periodicals, Inc.
Lee, Jiwon; Boutz, Daniel R; Chromikova, Veronika; Joyce, M Gordon; Vollmers, Christopher; Leung, Kwanyee; Horton, Andrew P; DeKosky, Brandon J; Lee, Chang-Han; Lavinder, Jason J; Murrin, Ellen M; Chrysostomou, Constantine; Hoi, Kam Hon; Tsybovsky, Yaroslav; Thomas, Paul V; Druz, Aliaksandr; Zhang, Baoshan; Zhang, Yi; Wang, Lingshu; Kong, Wing-Pui; Park, Daechan; Popova, Lyubov I; Dekker, Cornelia L; Davis, Mark M; Carter, Chalise E; Ross, Ted M; Ellington, Andrew D; Wilson, Patrick C; Marcotte, Edward M; Mascola, John R; Ippolito, Gregory C; Krammer, Florian; Quake, Stephen R; Kwong, Peter D; Georgiou, George
2016-12-01
Molecular understanding of serological immunity to influenza has been confounded by the complexity of the polyclonal antibody response in humans. Here we used high-resolution proteomics analysis of immunoglobulin (referred to as Ig-seq) coupled with high-throughput sequencing of transcripts encoding B cell receptors (BCR-seq) to quantitatively determine the antibody repertoire at the individual clonotype level in the sera of young adults before and after vaccination with trivalent seasonal influenza vaccine. The serum repertoire comprised between 40 and 147 clonotypes that were specific to each of the three monovalent components of the trivalent influenza vaccine, with boosted pre-existing clonotypes accounting for ∼60% of the response. An unexpectedly high fraction of serum antibodies recognized both the H1 and H3 monovalent vaccines. Recombinant versions of these H1 + H3 cross-reactive antibodies showed broad binding to hemagglutinins (HAs) from previously circulating virus strains; several of these antibodies, which were prevalent in the serum of multiple donors, recognized the same conserved epitope in the HA head domain. Although the HA-head-specific H1 + H3 antibodies did not show neutralization activity in vitro, they protected mice against infection with the H1N1 and H3N2 virus strains when administered before or after challenge. Collectively, our data reveal unanticipated insights regarding the serological response to influenza vaccination and raise questions about the added benefits of using a quadrivalent vaccine instead of a trivalent vaccine.
Wessels, Uwe; Schick, Eginhard; Ritter, Mirko; Kowalewsky, Frank; Heinrich, Julia; Stubenrauch, Kay
2017-06-01
Bridging immunoassays for detection of antidrug antibodies (ADAs) are typically susceptible to high concentrations of residual drug. Sensitive drug-tolerant assays are, therefore, needed. An immune complex assay to detect ADAs against therapeutic antibodies bearing Pro329Gly mutation was established. The assay uses antibodies specific for the Pro329Gly mutation for capture and human soluble Fcγ receptor for detection. When compared with a bridging assay, the new assay showed similar precision, high sensitivity to IgG1 ADA and dramatically improved drug tolerance. However, it was not able to detect early (IgM-based) immune responses. Applied in combination with a bridging assay, the novel assay serves as orthogonal assay for immunogenicity assessment and allows further characterization of ADA responses.
Chen, Tsu-Han; Lee, Fan; Lin, Yeou-Liang; Pan, Chu-Hsiang; Shih, Chia-Ni; Tseng, Chun-Hsien; Tsai, Hsiang-Jung
2016-04-01
Foot-and-mouth disease (FMD) and swine vesicular disease (SVD) are serious vesicular diseases that have devastated swine populations throughout the world. The aim of this study was to develop a multianalyte profiling (xMAP) Luminex assay for the differential detection of antibodies to the FMD virus of structural proteins (SP) and nonstructural proteins (NSP). After the xMAP was optimized, it detected antibodies to SP-VP1 and NSP-3ABC of the FMD virus in a single serum sample. These tests were also compared with 3ABC polypeptide blocking enzyme-linked immunosorbent assay (ELISA) and virus neutralization test (VNT) methods for the differential diagnosis and assessment of immune status, respectively. To detect SP antibodies in 661 sera from infected naïve pigs and vaccinated pigs, the diagnostic sensitivity (DSn) and diagnostic specificity (DSp) of the xMAP were 90.0-98.7% and 93.0-96.5%, respectively. To detect NSP antibodies, the DSn was 90% and the DSp ranged from 93.3% to 99.1%. The xMAP can detect the immune response to SP and NSP as early as 4 days postinfection and 8 days postinfection, respectively. Furthermore, the SP and NSP antibodies in all 15 vaccinated but unprotected pigs were detected by xMAP. A comparison of SP and NSP antibodies detected in the sera of the infected samples indicated that the results from the xMAP had a high positive correlation with results from the VNT and a 3ABC polypeptide blocking ELISA assay. However, simultaneous quantitation detected that xMAP had no relationship with the VNT. Furthermore, the specificity was 93.3-94.9% with 3ABC polypeptide blocking ELISA for the FMDV-NSP antibody. The results indicated that xMAP has the potential to detect antibodies to FMDV-SP-VP1 and NSP-3ABC and to distinguish FMDV-infected pigs from pigs infected with the swine vesicular disease virus. Copyright © 2014. Published by Elsevier B.V.
Mbwana, Judica; Ahmed, Hinda J; Ahlman, Karin; Sundaeus, Vivian; Dahlén, Gunnar; Lyamuya, Eligius; Lagergård, Teresa
2003-09-01
Antibodies specific for the cytolethal-distending toxin of Haemophilus ducreyi (HdCDT) complex and for the CdtA, CdtB, and CdtC components were measured by ELISA in the sera of 50 patients with culture and/or PCR proven chancroid, 42 patients with periodontitis, 50 blood donors from Tanzania, 50 blood donors from Sweden. In addition, the biological activity e.g. neutralization capacity of the sera were tested. Our results demonstrate that majority of chancroid patients and healthy individuals had detectable levels of serum antibodies to HdCDT complex and to separate toxin components. However, high levels (> or =100 units) of antibodies to HdCDT complex were significantly more prevalent in the sera of patients with both chancroid and periodontitis than in the sera of the corresponding controls (P=0.001 and P=0.04, respectively). In the sera of the 50 patients with chancroid, antibodies to CdtA, CdtB, and CdtC were detected in 50, 35, and 34 individuals, respectively. Antibodies to CdtC, being less frequently detected than the antibodies to other components, show a good correlation with the neutralizing capacity of sera. High levels of neutralizing antibodies (> or =160) were detected in only 22 and 2% of the patients with chancroid and periodontitis, respectively. The data suggest that the low levels of anti-HdCDT antibodies, which include neutralizing antibodies, may contribute to limited protection in chancroid and since anti-HdCDT antibodies, may be detected in healthy individuals and in patients with certain disease conditions (e.g. periodontitis), they may not be specific markers for chancroid infection.
Thakur, M.L.
1990-04-17
The invention discloses improved reagents containing antibodies against stage specific embryonic antigen-1 antibodies and improved methods for detection of occult abscess and inflammation using the improved reagents. No Drawings
Clinical cytometry and progress in HLA antibody detection.
Bray, Robert A; Tarsitani, Christine; Gebel, Howard M; Lee, Jar-How
2011-01-01
For most solid organ and selected stem cell transplants, antibodies against mismatched HLA antigens can lead to early and late graft failure. In recognition of the clinical significance of these antibodies, HLA antibody identification is one of the most critical functions of histocompatibility laboratories. Early methods employed cumbersome and insensitive complement-dependent cytotoxicity assays with a visual read-out. A little over 20 years ago flow cytometry entered the realm of antibody detection with the introduction of the flow cytometric crossmatch. Cytometry's increased sensitivity and objectivity quickly earned it popularity as a preferred crossmatch method especially for sensitized recipients. Although a sensitive method, the flow crossmatch was criticized as being "too sensitive" as false positive reactions were a know drawback. In part, the shortcomings of the flow crossmatch were due to the lack of corresponding sensitive and specific HLA antibody screening assays. However, in the mid 1990s, solid phase assays, capable of utilizing standard flow cytometers, were developed. These assays used microparticles coated with purified HLA molecules. Hence, the era of solid-phase, microparticle technology for HLA antibody detection was born permitting the sensitive and specific detection of HLA antibody. It was now possible to provide better correlation between HLA antibody detection and the flow cytometric crossmatch. This flow-based technology was soon followed by adaptation to the Luminex platform permitting a mutltiplexed approach for the identification and characterization of HLA antibodies. It is hoped that these technologies will ultimately lead to the identification of parameters that best correlate with and/or predict transplant outcomes. Copyright © 2011 Elsevier Inc. All rights reserved.
Snider, D P; Underdown, B J
1986-04-01
We analyzed the appearance and level of Giardia muris-specific antibody of immunoglobulin A (IgA), IgG, and IgM isotypes, at weekly intervals, over the course of a 7-week infection in BALB/c and C57BL/6 mice. Using sensitive immunoradiometric assays, we observed that IgA antibody was the only detectable anti-G. muris antibody in intestinal secretions throughout the course of infection. No secreted IgG or IgM anti-G. muris antibody was detected even in concentrated intestinal secretions. The expulsion of G. muris by the mice was associated closely with the appearance and increasing levels of secreted anti-G. muris IgA antibody. Both IgG and IgA serum antibody to G. muris were detected, but no serum IgM antibody was detected. Serum IgA and IgG anti-G. muris antibody remained at high levels up to 10 weeks following clearance of the parasite. An interesting observation indicated that serum IgA antibody to G. muris developed more slowly in response to infection than secreted IgA antibody. An analysis of the molecular weight distribution of total serum IgA in infected mice determined that infection produced a transient but significant shift in serum IgA to high-molecular-weight (greater than or equal to dimeric IgA) forms. The results indicate that a substantial IgA antibody response occurs in sera and in gut secretions of G. muris-resistant mice and that IgA antibody is the dominant and possibly the only effector antibody active in intestinal secretions during G. muris infection in mice.
Dzagurova, T K; Solopova, O N; Sveshnikov, P G; Korotina, N A; Balovneva, M V; Leonovich, O A; Varlamov, N E; Malkin, G A; Sotskova, S E; Tkachenko, E A
2013-01-01
The monoclonal antibodies to Puumala, Dobrava, Hantaan, and Seoul hantaviruses were obtained using mice. The viruses were known to cause HFRS, and two variants of ELISA were designed. First, Hanta-PUU variant, was constructed using monoclonal antibodies to Puumala virus envelope glycoprotein (G(N):G(C)) for detecting only Puumala virus antigen. The second, Hanta-N variant, was constructed using monoclonal antibodies to Dobrava and Puumala nucleocapsid proteins for detecting four above mentioned hantaviruses. Both Hanta-PUU and Hanta-N assays were reliable in detecting specific hantavirus antigens and the immunogenecity of hantavirus vaccines.
[Myositis-specific antibodies associated with juvenile dermatomyositis].
Eising, K; Peitz, J; Unterwalder, N; Meisel, C; Horneff, G
2018-02-06
Juvenile dermatomyositis (JDM) is a rare autoimmune disease associated with typical skin changes and muscle weakness. Within the framework of the diagnostics, myositis-associated (MAA) and myositis-specific antibodies (MSA) can be detected. These are important for the assessment of the course of the disease and the prognosis. In this study we searched for MAA and MSA by means of a line immunoassay in 12 currently supervised JDM patients in the Rheumatism Center Sankt Augustin. In 10 of the 12 patients a total of 15 myositis antibodies were detected where 3 patients each had Mi2, SRP or NXP2 antibodies, 2 had TIF-1γ antibodies and Jo1 or Mi2β antibodies were found in 1 patient each. Of the patients two had additional PM-Scl antibodies. In the 10 patients with detected antibodies, a good phenotype-serotype correlation was found with deviation from the phenotypes described in the literature in only 3 patients. The frequent detection of certain antibodies and the good correlation with those phenotypes described in the literature, show that the determination of MSA is an important diagnostic tool to assess the course, complications and outcome and to initiate adequate therapy at an early stage.
Tan, Liming; Zhang, Yuhong; Peng, Weihua; Chen, Juanjuan; Li, Hua; Ming, Feng
2014-01-01
Anti-lactoferrin antibodies (ALA) and anti-myeloperoxidase antibodies (AMPA) are specific serological markers for autoimmune hepatitis (AIH). The project aimed to detect ALA and AMPA and explore their clinical significances in AIH patients. 59 AIH patients, 217 non AIH patients, and 50 healthy controls were enrolled in this study. ALA and AMPA were detected by ELISA. Antineutropil cytoplasmic antibodies (ANCA) and anti-smooth muscle antibodies (ASMA) were examined by indirect immunofluorescence. Antimitochondrial antibody M2 subtype (AMA-M2), anti-liver kidney microsomal antibody Type 1 (LKM1), anti-liver cytosol antibody Type 1 (LC1), and anti-soluble liver antigen/liver-pancreas antibodies (SLA/LP) were tested by immunoblot. The positivity for ALA was 18.6% in AIH group, only one patient in non-AIH group was positive for ALA; the positivity for AMPA was 59.3% in AIH group, with significant differences (P < 0.01) compared with other groups. The specificities for ALA and AMPA were 99.63% and 97.75%; the sensitivities were 18.64% and 59.32%; and the accuracy rates were 84.97% and 90.80%, respectively. A certain correlation was observed between ALA and SLA/LP, AMPA and ANCA, ASMA in AIH group. ALA and AMPA were associated with AIH, and had high clinical diagnostic value. Co-detection with other relative autoantibodies could play an important role in differential diagnosis of AIH.
The indirect fluorescent antibody technique as a method for detecting antibodies in aborted fetuses.
Miller, R B; Wilkie, B N
1979-01-01
In this investigation the indirect fluorescent antibody technique was used to titrate antibodies in bovine sera to parainfluenza 3, infectious bovine rhinotracheitis virus and bovine viral diarrhea virus. These results were compared to those determined on the same samples by hemagglutination inhibition for parainfluenza 3 virus and serum neutralization for bovine virus diarrhea and infectious bovine rhinotracheitis virus. The results of the serological methods agreed closely. The indirect fluorescent antibody technique is a rapid and sensitive method for detecting antibodies and the procedure lends itself to use in diagnostic laboratories. In addition to the above viruses the presence or absence of antibodies to bovine coronavirus and bovine adenovirus 3 were determined by the indirect fluorescent antibody technique in thoracic fluids from 100 aborted fetuses and 50 nonaborted fetuses. Results on these samples were not compared to hemagglutination inhibition or serum neutralization as the condition of fluid samples from aborted fetuses renders interpretation of such tests unreliable. Antibodies to one or more viruses were detected in 30 of the 100 aborted fetuses and in seven of the 50 nonaborted fetuses. Antibodies to more than one agent were detected in eleven of the 100 aborted and in one of the 50 nonaborted fetuses. Reasons for this occurrence and application of the test in determination of causes of abortion are discussed. PMID:226243
Metildi, Cristina A; Kaushal, Sharmeela; Luiken, George A; Talamini, Mark A; Hoffman, Robert M; Bouvet, Michael
2014-04-01
The aim of this study was to evaluate a new fluorescently labeled chimeric anti-CEA antibody for improved detection and resection of colon cancer. Frozen tumor and normal human tissue samples were stained with chimeric and mouse antibody-fluorophore conjugates for comparison. Mice with patient-derived orthotopic xenografts (PDOX) of colon cancer underwent fluorescence-guided surgery (FGS) or bright-light surgery (BLS) 24 hr after tail vein injection of fluorophore-conjugated chimeric anti-CEA antibody. Resection completeness was assessed using postoperative images. Mice were followed for 6 months for recurrence. The fluorophore conjugation efficiency (dye/mole ratio) improved from 3-4 to >5.5 with the chimeric CEA antibody compared to mouse anti-CEA antibody. CEA-expressing tumors labeled with chimeric CEA antibody provided a brighter fluorescence signal on frozen human tumor tissues (P = 0.046) and demonstrated consistently lower fluorescence signals in normal human tissues compared to mouse antibody. Chimeric CEA antibody accurately labeled PDOX colon cancer in nude mice, enabling improved detection of tumor margins for more effective FGS. The R0 resection rate increased from 86% to 96% with FGS compared to BLS. Improved conjugating efficiency and labeling with chimeric fluorophore-conjugated antibody resulted in better detection and resection of human colon cancer in an orthotopic mouse model. © 2013 Wiley Periodicals, Inc.
Sawai, H.; Domae, N.
2010-01-01
Mouse monoclonal anti-Fas (CD95) antibody clone CH-11 has been widely used in research on apoptosis. CH-11 has the ability to bind to Fas protein on cell surface and induce apoptosis. Here, we used polystyrene beads coated with CH-11 to investigate the role of lipid rafts in Fas-mediated apoptosis in SKW6.4 cells. Unexpectedly, by treatment of the cells with CH-11-coated beads Fas protein was detached from cell surface and transferred to the surface of CH-11-coated beads. Western blot analysis showed that Fas protein containing both extracellular and intracellular domains was attached to the beads. Fas protein was not transferred from the cells to the surface of the beads coated with other anti-Fas antibodies or Fas ligand. Similar phenomenon was observed in Jurkat T cells. Furthermore, CH-11-induced apoptosis was suppressed by pretreatment with CH-11-coated beads in Jurkat cells. These results suggest that CH-11 might possess distinct properties on Fas protein compared with other anti-Fas antibodies or Fas ligand, and also suggest that caution should be needed to use polystyrene beads coated with antibodies such as CH-11. PMID:20353915
Fabrication of antibody microarrays by light-induced covalent and oriented immobilization.
Adak, Avijit K; Li, Ben-Yuan; Huang, Li-De; Lin, Ting-Wei; Chang, Tsung-Che; Hwang, Kuo Chu; Lin, Chun-Cheng
2014-07-09
Antibody microarrays have important applications for the sensitive detection of biologically important target molecules and as biosensors for clinical applications. Microarrays produced by oriented immobilization of antibodies generally have higher antigen-binding capacities than those in which antibodies are immobilized with random orientations. Here, we present a UV photo-cross-linking approach that utilizes boronic acid to achieve oriented immobilization of an antibody on a surface while retaining the antigen-binding activity of the immobilized antibody. A photoactive boronic acid probe was designed and synthesized in which boronic acid provided good affinity and specificity for the recognition of glycan chains on the Fc region of the antibody, enabling covalent tethering to the antibody upon exposure to UV light. Once irradiated with optimal UV exposure (16 mW/cm(2)), significant antibody immobilization on a boronic acid-presenting surface with maximal antigen detection sensitivity in a single step was achieved, thus obviating the necessity of prior antibody modifications. The developed approach is highly modular, as demonstrated by its implementation in sensitive sandwich immunoassays for the protein analytes Ricinus communis agglutinin 120, human prostate-specific antigen, and interleukin-6 with limits of detection of 7.4, 29, and 16 pM, respectively. Furthermore, the present system enabled the detection of multiple analytes in samples without any noticeable cross-reactivities. Antibody coupling via the use of boronic acid and UV light represents a practical, oriented immobilization method with significant implications for the construction of a large array of immunosensors for diagnostic applications.
One-Step Immunochromatography Assay Kit for Detecting Antibodies to Canine Parvovirus
Oh, Jin-Sik; Ha, Gun-Woo; Cho, Young-Shik; Kim, Min-Jae; An, Dong-Jun; Hwang, Kyu-Kye; Lim, Yoon-Kyu; Park, Bong-Kyun; Kang, BoKyu; Song, Dae-Sub
2006-01-01
This study was performed to determine the feasibility of using whole serum to detect antibodies to canine parvovirus (CPV) under nonlaboratory conditions and to evaluate the performance characteristics of an immunochromatography assay kit. Precise detection of levels of antibody against CPV in puppies can be used to determine a vaccination schedule, because maternal antibodies frequently result in the failure of protective vaccination, and can also be used to determine the antibody levels of infected puppies. Several methods for the titration of CPV antibodies have been reported, including the hemagglutination inhibition (HI) assay, which is considered the “gold standard.” These methods, however, require intricate and time-consuming procedures. In this study, a total of 386 serum specimens were tested. Compared to the HI assay, the rapid assay had a 97.1% sensitivity and a 76.6% specificity (with a cutoff HI titer of 1:80). This single-step assay could be performed rapidly and easily without special equipment. The kit provides a reliable method for detection of anti-CPV antibody where laboratory support and personnel are limited. PMID:16603622
One-step immunochromatography assay kit for detecting antibodies to canine parvovirus.
Oh, Jin-Sik; Ha, Gun-Woo; Cho, Young-Shik; Kim, Min-Jae; An, Dong-Jun; Hwang, Kyu-Kye; Lim, Yoon-Kyu; Park, Bong-Kyun; Kang, BoKyu; Song, Dae-Sub
2006-04-01
This study was performed to determine the feasibility of using whole serum to detect antibodies to canine parvovirus (CPV) under nonlaboratory conditions and to evaluate the performance characteristics of an immunochromatography assay kit. Precise detection of levels of antibody against CPV in puppies can be used to determine a vaccination schedule, because maternal antibodies frequently result in the failure of protective vaccination, and can also be used to determine the antibody levels of infected puppies. Several methods for the titration of CPV antibodies have been reported, including the hemagglutination inhibition (HI) assay, which is considered the "gold standard." These methods, however, require intricate and time-consuming procedures. In this study, a total of 386 serum specimens were tested. Compared to the HI assay, the rapid assay had a 97.1% sensitivity and a 76.6% specificity (with a cutoff HI titer of 1:80). This single-step assay could be performed rapidly and easily without special equipment. The kit provides a reliable method for detection of anti-CPV antibody where laboratory support and personnel are limited.
Serum transglutaminase 3 antibodies correlate with age at celiac disease diagnosis.
Salmi, Teea T; Kurppa, Kalle; Hervonen, Kaisa; Laurila, Kaija; Collin, Pekka; Huhtala, Heini; Saavalainen, Päivi; Sievänen, Harri; Reunala, Timo; Kaukinen, Katri
2016-06-01
Transglutaminase (TG)2 is the autoantigen in celiac disease, but also TG3 antibodies have been detected in the serum of celiac disease patients. To investigate the correlations between serum TG3 antibodies and clinical and histological manifestations of celiac disease and to assess gluten-dependency of TG3 antibodies. Correlations between serum TG3 antibody levels measured from 119 adults and children with untreated coeliac disease and the demographic data, clinical symptoms, celiac antibodies, histological data and results of laboratory tests and bone mineral densities were tested. TG3 antibodies were reinvestigated in 97 celiac disease patients after 12 months on a gluten-free diet (GFD). TG3 antibody titers were shown to correlate with the age at celiac disease diagnosis. Further, negative correlation with TG3 antibodies and intestinal γδ+ cells at diagnosis and on GFD was detected. Correlations were not detected with the clinical manifestation of celiac disease, TG2 or endomysial autoantibodies, laboratory values, severity of mucosal villous atrophy, associated diseases or complications. TG3 antibody titers decreased on GFD in 56% of the TG3 antibody positive patients. Serum TG3 antibody positivity in celiac disease increases as the diagnostic age rises. TG3 antibodies did not show similar gluten-dependency as TG2 antibodies. Copyright © 2016 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
Hillig, Roman C; Urlinger, Stefanie; Fanghänel, Jörg; Brocks, Bodo; Haenel, Cornelia; Stark, Yvonne; Sülzle, Detlev; Svergun, Dmitri I; Baesler, Siegfried; Malawski, Guido; Moosmayer, Dieter; Menrad, Andreas; Schirner, Michael; Licha, Kai
2008-03-14
Molecular interactions between near-IR fluorescent probes and specific antibodies may be exploited to generate novel smart probes for diagnostic imaging. Using a new phage display technology, we developed such antibody Fab fragments with subnanomolar binding affinity for tetrasulfocyanine, a near-IR in vivo imaging agent. Unexpectedly, some Fabs induced redshifts of the dye absorption peak of up to 44 nm. This is the largest shift reported for a biological system so far. Crystal structure determination and absorption spectroscopy in the crystal in combination with microcalorimetry and small-angle X-ray scattering in solution revealed that the redshift is triggered by formation of a Fab dimer, with tetrasulfocyanine being buried in a fully closed protein cavity within the dimer interface. The derived principle of shifting the absorption peak of a symmetric dye via packaging within a Fab dimer interface may be transferred to other diagnostic fluorophores, opening the way towards smart imaging probes that change their wavelength upon interaction with an antibody.
California serogroup and Powassan virus infection of cats.
Keane, D P; Parent, J; Little, P B
1987-08-01
One hundred and seventy five sera from cats in Ontario, Canada, were tested for hemagglutination inhibition (HI) antibodies to three arboviruses; namely, Powassan (POW) of the Flavivirus serogroup, and Snowshoe hare (SSH) and Jamestown Canyon (JC) viruses of the California (CAL) serogroup. All sera were negative for antibodies to POW virus. Twelve cats possessed CAL serogroup antibodies including 3 with antibodies to SSH alone, 6 with antibodies to JC alone, and 3 with antibodies to both SSH and JC antigens. POW virus was inoculated into seven cats, one intracerebrally and six intravenously. Neurologic signs were not detected in any of the cats. Histologic lesions of a nonsuppurative encephalitis and encephalomyelitis were observed in the intracerebrally inoculated cat and in one of the intravenously inoculated cats, respectively. POW virus was not isolated from the brain or spinal cord of either of these two cats. HI antibodies were detected in the sera of all inoculated animals. HI antibodies were not detected in the CSF of any animal.
Schultze, Detlev; Weder, Bruno; Cassinotti, Pascal; Vitek, Lucie; Krausse, Konrad; Fierz, Walter
2004-11-27
The optimal strategy for the diagnosis of herpes simplex virus (HSV) and varizella-zoster virus (VZV) disease of the central nervous system is the detection of viral DNA by polymerase chain reaction assay (PCR) in cerebrospinal fluid (CSF) and the examination of intrathecal production of specific antibodies. However, in acute neurological disease caused by either HSV or VZV, dual intrathecal synthesis of HSV-1, 2- as well as VZV-specific antibodies may be detectable and thus can hamper accurate aetiological diagnosis. This paper illustrates such equivocal findings in two case reports, investigates their frequency and discusses the possible reasons. Consecutive CSF/serum pairs of two patients with central nervous system (CNS) disease were tested by HSV-1-, HSV-2-, and VZV-specific PCR and by different serological assays for detection of neurotropic viruses and bacteria. Additionally, the results of microbiological investigations of 1'155 CSF/serum samples were retrospectively analyzed for coincident intrathecal antibody synthesis against HSV-1, 2 and VZV. Although only HSV-1 and VZV-specific DNA was detectable in the CSF of two patients with encephalitis and chronic meningitis, respectively, increasing intrathecal antibody production against both virus species could be demonstrated. Retrospective analysis of 1155 CSF/serum pairs revealed 55 (4.8%) pairs with evidence for intrathecally produced antibodies against either HSV-1, 2 (30/55) or VZV (14/55). Eleven of these 55 (20%) pairs showed intrathecal antibody-production against both virus species. Patients with CNS infection with HSV and VZV can be diagnosed by detecting intrathecally produced virus-specific antibodies, in addition to virus-specific PCR. However, in an appreciable proportion of patients a correct diagnosis is hampered by coincidentally detected antibodies in CSF against both virus species. Possible reasons for these equivocal findings are given.
Bernardes Filho, Fred; de Abreu, Marilda M. M.; Botini, Patrícia; Duthie, Malcolm S.; Spencer, John S.; Soares, Rosa Castália F. R.
2017-01-01
Background Leprosy diagnosis is mainly based on clinical evaluation, although this approach is difficult, especially for untrained physicians. We conducted a temporary campaign to detect previously unknown leprosy cases in midwestern Brazil and to compare the performance of different serological tests. Methods A mobile clinic was stationed at the main bus terminal in Brasília, Brazil. Volunteers were quizzed and given a clinical exam to allow categorization as either patients, known contacts of patients or non-contacts, and blood was collected to determine anti-PGL-I and anti-LID-1 antibody titers by ELISA and by the NDO-LID rapid test. New cases of leprosy and the impact of performing this broad random surveillance strategy were evaluated. Accuracy values and concordance between the test results were evaluated among all groups. Results Four hundred thirty-four individuals were evaluated, and 44 (10.1%) were diagnosed with leprosy. Borderline forms were the most frequent presentation. Both tests presented higher positivity in those individuals with multibacillary disease. Serological tests demonstrated specificities arround 70% for anti-PGL-1 and anti-LID ELISA; and arround 40% for NDO-LID. Sensitivities ranged from 48 to 62%. A substantial agreement between NDO-LID and ELISA with concomitant positive results was found within leprosy patients (Kappa index = 0.79 CI95% 0.36–1.22). Conclusions The unexpectedly high leprosy prevalence in this population indicates ongoing community-based exposure to Mycobacterium leprae antigens and high rates of subclinical infection. All tests showed low specificity and sensitivity values and therefore cannot be considered for use as stand-alone diagnostics. Rather, considering their positivity among MB patients and non-patients, these tests can be considered effective tools for screening and identifying individuals at high risk who might benefit from regular monitoring. PMID:28231244
Panyasing, Y; Goodell, C K; Wang, C; Kittawornrat, A; Prickett, J R; Schwartz, K J; Ballagi, A; Lizano, S; Zimmerman, J J
2014-04-01
In commercial swine populations, influenza is an important component of the porcine respiratory disease complex (PRDC) and a pathogen with major economic impact. Previously, a commercial blocking ELISA (FlockChek(™) Avian Influenza Virus MultiS-Screen(®) Antibody Test Kit, IDEXX Laboratories, Inc., Westbrook, ME, USA) designed to detect influenza A nucleoprotein (NP) antibodies in avian serum was shown to accurately detect NP antibodies in swine serum. The purpose of this study was to determine whether this assay could detect NP antibodies in swine oral fluid samples. Initially, the procedure for performing the NP-blocking ELISA on oral fluid was modified from the serum testing protocol by changing sample dilution, sample volume, incubation time and incubation temperature. The detection of NP antibody was then evaluated using pen-based oral fluid samples (n = 182) from pigs inoculated with either influenza A virus subtype H1N1 or H3N2 under experimental conditions and followed for 42 days post inoculation (DPI). NP antibodies in oral fluid were detected from DPI 7 to 42 in all inoculated groups, that is, the mean sample-to-negative (S/N) ratio of influenza-inoculated pigs was significantly different (P < 0.0001) from uninoculated controls (unvaccinated or vaccinated-uninoculated groups) through this period. Oral fluid versus serum S/N ratios from the same pen showed a correlation of 0.796 (Pearson's correlation coefficient, P < 0.0001). The results showed that oral fluid samples from influenza virus-infected pigs contained detectable levels of NP antibodies for ≥42 DPI. Future research will be required to determine whether this approach could be used to monitor the circulation of influenza virus in commercial pig populations. © 2012 Blackwell Verlag GmbH.
Development of solid - based paper strips for rapid diagnosis of Pseudorabies infection.
Joon Tam, Yew; Mohd Lila, Mohd Azmi; Bahaman, Abdul Rani
2004-12-01
Pseudorabies (Aujeszky's disease) is an economically significant disease of swine known to cause central nervous disorders, respiratory disease, reproductive failure and mortality in infected pigs. In attempts to eradicate the disease from becoming endemic, early detection is important to prevent further economic losses and to allow for detection and removal of infected pigs in domestic herds. Thus, a rapid and sensitive technique is necessary for the detection of the virus. For rapid and simple examination, an immuno - chromatographic lateral - flow assay system based on immunologic recognition of specific pseudorabies virus antigen was developed by utilising, as signal generator, colloidal gold conjugated to secondary antibody to detect primary or sample antibody in the sera of pseudorabies infected animals. The pseudorabies virus used as a capture antigen in the test strip was first cultivated in VERO cell culture and then purified by sucrose gradient separation to produce the viral protein concentration of 3.8 mg/ml. The standard pseudorabies antigens reacted well with the hyperimmune serum (HIS). The antibody detection system is basically composed of colloidal gold - labelled antibodies fixed on a conjugate pad, and the complementary pseudorabies antigen immobilised onto a nitrocellulose membrane forming capture zone. If the target antibody is present in a specimen, the colloidal gold-labelled antibody will form a complex with the antibody sample. Subsequently, the formed complex will migrate to the capture zone and is then bound to the solid phase via antigen - antibody interaction. As a result, a signal marker is generated by the accumulation of colloidal gold for detection confirmation. The results obtained demonstrated that the optimum combination of pseudorabies antigen needed as the capture reagent and gold conjugate as secondary antibody recognition marker was at a concentration of 0.38mg/ml and at 1:10 dilution factor respectively. The sensitivity of the solid - based test strip towards pseudorabies antibodies was high with a detection limit of 1 to 10,000 - dilution factor. The specificity of the assay was 100% with no cross - reaction being observed with other sera or antibodies. Accurate reading time needed for confirmation of the assay can be completed in 5 min with a whole blood sample of 25 microl. The colloidal gold - labelled antibody is stable at room temperature for 6 months or more (data not shown). Findings from this study indicated that the solid - based test strip assay system provided high sensitivity and specificity for the detection of pseudorabies at low levels of antibody concentration. The assay was rapid, simple, cheap, and does not require any sophisticated equipment. Thus, the solid based test strip will be a useful serological screening technique or for rapid diagnosis of an infectious disease in target populations of animals characterised by heterogeneous antibody responses.
New Stx2e monoclonal antibodies for immunological detection and distinction of Stx2 subtypes
USDA-ARS?s Scientific Manuscript database
Background Stx2e is a primary virulence factor in STEC strains that cause edema disease in neonatal piglets. Though Stx2a and Stx2e are similar, most antibody-based Stx detection kits are designed to detect Stx2a and do not recognize the Stx2e subtype. Methods and Findings Four monoclonal antibodie...
Zupańska, B; Maślanka, K; van Loghem, E
1982-11-01
13 anti-Rh sera were compared for their usefulness in the detection of Fc-receptor-bearing lymphocytes (EAhum test). IgG subclasses of anti-Rh antibodies were determined by the antiglobulin test with monospecific sera and by the detection of Gm allotypic markers in the haemagglutination inhibition test. Six sera with IgG1 + IgG3 or IgG1 + IgG2 + IgG3 antibodies and one with pure IgG3 antibodies were found to be useful, whereas six other sera with only IgG1 were unsuitable for the EAhum test. G3m markers were detected only on the anti-Rh antibodies which were capable of forming rosettes with lymphocytes. The data show that human peripheral lymphocytes possess Fc receptors for IgG3 immunoglobulins.
ABO blood group antibody levels in infants exposed to mechanical circulatory support.
Guynes, Anthony; Delaney, Meghan; McMullan, David M; Townsend-McCall, Dee; Kemna, Mariska; Boucek, Robert; Law, Yuk M
2014-01-01
ABO sensitization is a barrier to ABO-incompatible heart transplantation in infants. We investigate the development of ABO antibodies in infants with and without mechanical circulatory support (MCS) during their waiting period. Although the proportion of patients with antibodies was similar between the groups, the median age at antibody detection was only 9 days (6-198) for MCS vs. 223 days (28-367) for non-MCS patients (P = 0.028), suggesting MCS is associated with earlier ABO antibody detection.
McElhiney, J; Lawton, L A; Porter, A J
2000-12-01
Single-chain antibody fragments against the cyanobacterial hepatotoxin microcystin-LR were isolated from a naive human phage display library and expressed in Escherichia coli. In competition enzyme-linked immunosorbent assay (ELISA), the most sensitive antibody clone selected from the library detected free microcystin-LR with an IC(50) value of 4 microM. It was found to cross react with three other microcystin variants - microcystin-RR, microcystin-LW and microcystin-LF - and detected microcystins in extracts of the cyanobacterium Microcystis aeruginosa, found to contain the toxins by high-performance liquid chromatography (HPLC). The quantification of microcystins in these extracts by ELISA and HPLC showed good correlation. Although the antibody isolated in this study was considerably less sensitive than the polyclonal and monoclonal antibodies already available for microcystin detection, phage display technology represents a cheaper, more rapid alternative for the production of anti-microcystin antibodies than the methods currently in use.
Liu, Xiao; Zhu, Ling; Shi, Xiaohong; Xu, Zhiwen; Mei, Miao; Xu, Weiwei; Zhou, Yuancheng; Guo, Wanzhu; Wang, Xiaoyu
2012-12-01
The major epitope region of the glycoprotein B (gB) gene of the porcine cytomegalovirus (PCMV), with a length of 270 bp, was cloned and expressed in Escherichia coli Rosetta (DE3). The major gB epitope was detected using an agar gel precipitation and Western blot analysis with the polyclonal antibodies specific for the major epitope. An indirect-blocking enzyme-linked immunosorbent assay (ELISA) was developed using the expressed major gB epitope as a coating antigen for the detection of PCMV antibodies. The results of the tests show that the indirect-blocking ELISA has 98% specificity and 97.8% sensitivity. No cross-reactions were observed between the major gB epitope and the antibodies against other virus, which indicates that the gB epitope is specific for PCMV antibodies. The indirect-blocking ELISA is a highly specific, sensitive method for detecting anti-PCMV gB antibodies. Copyright © 2012 Elsevier B.V. All rights reserved.
Monoclonal antibodies and method for detecting dioxins and dibenzofurans
Vanderlaan, Martin; Stanker, Larry H.; Watkins, Bruce E.; Bailey, Nina R.
1989-01-01
Compositions of matter are described which include five monoclonal antibodies that react with dioxins and dibenzofurans, and the five hybridomas that produce these monoclonal antibodies. In addition, a method for the use of these antibodies in a sensitive immunoassay for dioxins and dibenzofurans is given, which permits detection of these pollutants in samples at concentrations in the range of a few parts per billion.
USDA-ARS?s Scientific Manuscript database
Serologic tools for rapid testing of subtype-specific influenza A (IA) virus antibody in wild birds and poultry are limited. In the current study, the ID Screen Influenza H5 Antibody Competition enzyme-linked immunosorbent assay (ELISA) was tested for the detection of antibodies to the H5 subtype o...
USDA-ARS?s Scientific Manuscript database
An accurate and simple-to-perform new version of a competitive ELISA (cELISA) kit that became commercially available in 2015 for testing of cattle for antibody to Anaplasma marginale was validated for detection of Anaplasma ovis antibody in domestic sheep. True positives and negatives were identifie...
Shinchi, Hiroyuki; Yuki, Nobuhiro; Ishida, Hideharu; Hirata, Koichi; Wakao, Masahiro; Suda, Yasuo
2015-01-01
Sugar chain binding antibodies have gained substantial attention as biomarkers due to their crucial roles in various disorders. In this study, we developed simple and quick detection method of anti-sugar chain antibodies in sera using our previously developed sugar chain-immobilized fluorescent nanoparticles (SFNPs) for the point-of-care diagnostics. Sugar chain structure on SFNPs was modified with the sugar moieties of the GM1 ganglioside via our original linker molecule to detect anti-GM1 antibodies. The structures and densities of the sugar moieties immobilized on the nanoparticles were evaluated in detail using lectins and sera containing anti-GM1 antibodies from patients with Guillain-Barré syndrome, a neurological disorder, as an example of disease involving anti-sugar chain antibodies. When optimized SFNPs were added to sera from patients with Guillain-Barré syndrome, fluorescent aggregates were able to visually detect under UV light in three hours. The sensitivity of the detection method was equivalent to that of the current ELISA method used for the diagnosis of Guillain-Barré syndrome. These results suggest that our method using SFNPs is suitable for the point-of-care diagnostics of diseases involving anti-sugar chain antibodies.
Athanasiou, Labrini V; Petanides, Theodoros A; Chatzis, Manolis K; Kasabalis, Dimitrios; Apostolidis, Kosmas N; Saridomichelakis, Manolis N
2014-03-01
Antibodies against Leishmania spp. are detected in most dogs with clinical signs of leishmaniasis due to Leishmania infantum. Accurate, rapid in-clinic serological tests may permit immediate confirmation of the diagnosis and implementation of therapeutic measures. The aim of the current study was to evaluate the diagnostic accuracy of 2 commercial, rapid in-clinic serological tests for the detection of anti-Leishmania antibodies in sera of dogs, the Snap Canine Leishmania Antibody Test kit (IDEXX Laboratories Inc., Westbrook, Maine) and the ImmunoRun Antibody Detection kit (Biogal Galed Labs, Kibbutz Galed, Israel), using indirect fluorescent antibody test (IFAT) as the reference method. A total of 109 sera collected from 65 seropositive and 44 seronegative dogs were used. The sensitivities of the Snap and ImmunoRun kits were 89.23% (95% confidence interval: 79.05-95.54%) and 86.15% (95% confidence interval: 75.33-93.45%), respectively, and the specificity of both tests was 100%. A good agreement between each of the rapid in-clinic serological tests and IFAT and between the 2 rapid in-clinic serological tests was witnessed. Both rapid in-clinic serological tests showed an adequate diagnostic accuracy and can be used for the fast detection of antibodies against L. infantum in dogs.
Geuijen, Cecilia A W; Clijsters-van der Horst, Marieke; Cox, Freek; Rood, Pauline M L; Throsby, Mark; Jongeneelen, Mandy A C; Backus, Harold H J; van Deventer, Els; Kruisbeek, Ada M; Goudsmit, Jaap; de Kruif, John
2005-07-01
Application of antibody phage display to the identification of cell surface antigens with restricted expression patterns is often complicated by the inability to demonstrate specific binding to a certain cell type. The specificity of an antibody can only be properly assessed when the antibody is of sufficient high affinity to detect low-density antigens on cell surfaces. Therefore, a robust and simple assay for the prediction of relative antibody affinities was developed and compared to data obtained using surface plasmon resonance (SPR) technology. A panel of eight anti-CD46 antibody fragments with different affinities was selected from phage display libraries and reformatted into complete human IgG1 molecules. SPR was used to determine K(D) values for these antibodies. The association and dissociation of the antibodies for binding to CD46 expressed on cell surfaces were analysed using FACS-based assays. We show that ranking of the antibodies based on FACS data correlates well with ranking based on K(D) values as measured by SPR and can therefore be used to discriminate between high- and low-affinity antibodies. Finally, we show that a low-affinity antibody may only detect high expression levels of a surface marker while failing to detect lower expression levels of this molecule, which may lead to a false interpretation of antibody specificity.
Antibody-based bacterial toxin detection
NASA Astrophysics Data System (ADS)
Menking, Darrell E.; Heitz, Jonathon M.; Anis, Nabil A.; Thompson, Roy G.
1994-03-01
Fiber optic evanescent fluorosensors are under investigation in our laboratory for the study of drug-receptor interactions for detection of threat agents and antibody-antigen interactions for detection of biological toxins. In a one step assay, antibodies against Cholera toxin or Staphylococcus Enterotoxin B were noncovalently immobilized on quartz fibers and probed with fluorescein-isothiocyanate (FITC)-labeled toxins. In the two-step assay, Cholera toxin or Botulinum toxoid A was immobilized onto the fiber, followed by incubation in an antiserum or partially purified antitoxin IgG. These were then probed with FITC-anti-IgG antibodies. Unlabeled toxins competed with labeled toxins or antitoxin IgG in a dose-dependent manner and the detection of the toxins was in the nanomolar range.
Erlanger, Bernard F.; Chen, Bi-Xing
1999-01-01
The subject invention provides an antibody which specifically binds to the product of a reaction between a labeling substance and a substrate. The subject invention also provides a method of making an immunogen used to produce the antibody of the subject invention. The invention further provides methods of using the subject antibody for detecting an antigen of interest in a sample, for example, detecting a protein comprising an amino acid sequence of interest and detecting a nucleic acid molecule comprising a nucleic acid sequence of interest, detecting a polypeptide such as those expressed by infectious agents, fungi or parasites.
Erlanger, B.F.; Chen, B.
1999-07-20
The subject invention provides an antibody which specifically binds to the product of a reaction between a labeling substance and a substrate. The subject invention also provides a method of making an immunogen used to produce the antibody of the subject invention. The invention further provides methods of using the subject antibody for detecting an antigen of interest in a sample, for example, detecting a protein comprising an amino acid sequence of interest and detecting a nucleic acid molecule comprising a nucleic acid sequence of interest, detecting a polypeptide such as those expressed by infectious agents, fungi or parasites. 25 figs.
Searching for Life on Mars: Selection of Molecular Targets for ESA's Aurora ExoMars Mission
NASA Astrophysics Data System (ADS)
Parnell, John; Cullen, David; Sims, Mark R.; Bowden, Stephen; Cockell, Charles S.; Court, Richard; Ehrenfreund, Pascale; Gaubert, Francois; Grant, William; Parro, Victor; Rohmer, Michel; Sephton, Mark; Stan-Lotter, Helga; Steele, Andrew; Toporski, Jan; Vago, Jorge
2007-08-01
The European Space Agency's ExoMars mission will seek evidence of organic compounds of biological and non-biological origin at the martian surface. One of the instruments in the Pasteur payload may be a Life Marker Chip that utilizes an immunoassay approach to detect specific organic molecules or classes of molecules. Therefore, it is necessary to define and prioritize specific molecular targets for antibody development. Target compounds have been selected to represent meteoritic input, fossil organic matter, extant (living, recently dead) organic matter, and contamination. Once organic molecules are detected on Mars, further information is likely to derive from the detailed distribution of compounds rather than from single molecular identification. This will include concentration gradients beneath the surface and gradients from generic to specific compounds. The choice of biomarkers is informed by terrestrial biology but is wide ranging, and nonterrestrial biology may be evident from unexpected molecular distributions. One of the most important requirements is to sample where irradiation and oxidation are minimized, either by drilling or by using naturally excavated exposures. Analyzing regolith samples will allow for the search of both extant and fossil biomarkers, but sequential extraction would be required to optimize the analysis of each of these in turn.
Judd, W J; Barnes, B A; Steiner, E A; Oberman, H A; Averill, D B; Butch, S H
1986-01-01
Direct antiglobulin tests (DATs) using anti-IgG were performed on 65,049 blood samples from prospective transfusion recipients; 3570 tests (5.49%) were positive. Using criteria published previously (primarily excluding patients not transfused within the preceding 14 days), 778 samples from other than neonatal patients were selected for further evaluation. Eluates that did not react were obtained on 518 (66.6%) of these samples. Warm-reactive autoantibodies were apparent in 192 eluates, while 16 contained drug-related antibodies, anti-A or anti-B from prior transfusion with ABO mismatched blood components, or anti-D passively acquired from immune serum globulin. Fifty-two eluates contained alloantibodies; however, in only six of these cases did the corresponding serum lack unexpected alloantibodies, as determined by routine pretransfusion studies. Three additional weakly reactive clinically significant alloantibodies were detected solely through additional serum tests performed on DAT-positive samples. On the basis of these findings, the DAT had a low predictive value when used to detect the early manifestations of an immune response to recently transfused red cells. Elimination of the autocontrol from routine pretransfusion testing, therefore, carries minimal risk to patients yet will undoubtedly contribute to the containment of health care costs. Moreover, the risk is lower than that associated with the elimination of the antiglobulin crossmatch.
Detection of unusual strains of RV in patients with acute diarrhoea in Mexico.
del R González-Losa, Maria; Rodríguez-Angulo, Elsa; Manzano-Cabrera, Luis; Mejía-Cámara, Javier; Puerto-Solís, Marylin
2005-04-01
Group A rotaviruses are a major cause of acute gastroenteritis in infants. Human strains with a short RNA pattern generally exhibit subgroup I, G2, P1B[4] specificity, those with a long RNA pattern show subgroup II, G1, G3 or G4, P1A[8] specificity. The presence of strains with unusual specificities has been reported worldwide over the last decade. To determine antigenic diversity among rotaviruses isolated from patients with diarrhoea. A laboratory-based survey study was carried out with faecal samples from patients with acute gastroenteritis form January to April 2000. To classify the samples PAGE and ELISA with specific antibodies to serotype G and P and RT-PCR were carried out. Twenty one specimens from patients with dehydrating diarrhoea had unusual specifies. Nine specimens had unusual combination of long pattern and subgroup I. Twelve specimens with short pattern belong to G1 serotype. As far as the serotypes and genotypes concern 11 samples were P1A, P[4] and one specimen was P1A, P[9]. These results demonstrated the unexpected presence of unusual strains of rotavirus in Mexico. Detection of strains with both human and animal characteristics may indicate interspecies transmission of RV between humans and animals.
Searching for life on Mars: selection of molecular targets for ESA's aurora ExoMars mission.
Parnell, John; Cullen, David; Sims, Mark R; Bowden, Stephen; Cockell, Charles S; Court, Richard; Ehrenfreund, Pascale; Gaubert, Francois; Grant, William; Parro, Victor; Rohmer, Michel; Sephton, Mark; Stan-Lotter, Helga; Steele, Andrew; Toporski, Jan; Vago, Jorge
2007-08-01
The European Space Agency's ExoMars mission will seek evidence of organic compounds of biological and non-biological origin at the martian surface. One of the instruments in the Pasteur payload may be a Life Marker Chip that utilizes an immunoassay approach to detect specific organic molecules or classes of molecules. Therefore, it is necessary to define and prioritize specific molecular targets for antibody development. Target compounds have been selected to represent meteoritic input, fossil organic matter, extant (living, recently dead) organic matter, and contamination. Once organic molecules are detected on Mars, further information is likely to derive from the detailed distribution of compounds rather than from single molecular identification. This will include concentration gradients beneath the surface and gradients from generic to specific compounds. The choice of biomarkers is informed by terrestrial biology but is wide ranging, and nonterrestrial biology may be evident from unexpected molecular distributions. One of the most important requirements is to sample where irradiation and oxidation are minimized, either by drilling or by using naturally excavated exposures. Analyzing regolith samples will allow for the search of both extant and fossil biomarkers, but sequential extraction would be required to optimize the analysis of each of these in turn.
Replication, pathogenicity, shedding, and transmission of Zaire ebolavirus in pigs.
Kobinger, Gary P; Leung, Anders; Neufeld, James; Richardson, Jason S; Falzarano, Darryl; Smith, Greg; Tierney, Kevin; Patel, Ami; Weingartl, Hana M
2011-07-15
(See the editorial commentary by Bausch, on pages 179-81.) Reston ebolavirus was recently detected in pigs in the Philippines. Specific antibodies were found in pig farmers, indicating exposure to the virus. This important observation raises the possibility that pigs may be susceptible to Ebola virus infection, including from other species, such as Zaire ebolavirus (ZEBOV), and can transmit to other susceptible hosts. This study investigated whether ZEBOV, a species commonly reemerging in central Africa, can replicate and induce disease in pigs and can be transmitted to naive animals. Domesticated Landrace pigs were challenged through mucosal exposure with a total of 1 ×10(6) plaque-forming units of ZEBOV and monitored for virus replication, shedding, and pathogenesis. Using similar conditions, virus transmission from infected to naive animals was evaluated in a second set of pigs. Following mucosal exposure, pigs replicated ZEBOV to high titers (reaching 10(7) median tissue culture infective doses/mL), mainly in the respiratory tract, and developed severe lung pathology. Shedding from the oronasal mucosa was detected for up to 14 days after infection, and transmission was confirmed in all naive pigs cohabiting with inoculated animals. These results shed light on the susceptibility of pigs to ZEBOV infection and identify an unexpected site of virus amplification and shedding linked to transmission of infectious virus.
Furtado, Agustin; Torres, Fabrício Dias; Franco, Ana Cláudia; Maisonnave, Jacqueline; Roehe, Paulo Michel
2016-01-01
Bovine herpesviruses (BoHVs) types 1 (BoHV-1) and 5 (BoHV-5) are alphaherpesviruses of major importance to the bovine production chain. Such viruses are capable of establishing latent infections in neuronal tissues. Infected animals tend to develop a serological response to infection; however, such response—usually investigated by antibody assays in serum—may eventually not be detected in laboratory assays. Nevertheless, serological tests such as virus neutralization (VN) and various enzyme-linked immunosorbent assays (ELISAs) are widely employed to check individual or herd status of BoHV infections. The correlation between detection of antibodies and the presence of viral nucleic acids as indicatives of infection in infected cattle has not been deeply examined. In order to investigate such correlation, 248 bovine serum samples were tested by VN to BoHV-1 and BoHV-5, as well as in a widely employed (though not type-differential) gB ELISA (IDEXX IBR gB X2 Ab Test) in search for antibodies to BoHVs. Immediately after blood withdrawal, cattle were slaughtered and trigeminal ganglia (TG) excised for DNA extraction and viral nucleic acid detection (NAD) by nested PCR. Neutralizing antibodies to BoHV-1 and/or BoHV-5 were detected in 44.8% (111/248) of sera, whereas the gB ELISA detected antibodies in 51.2% (127/248) of the samples. However, genomes of either BoHV-1, BoHV-5, or both, were detected in TGs of 85.9% (213/248) of the animals. These findings reveal that the assays designed to detect antibodies to BoHV-1 and/or BoHV-5 employed here may fail to detect a significant number of latently infected animals (in this study, 35.7%). From such data, it is clear that antibody assays are poorly correlated with detection of viral genomes in BoHV-1 and BoHV-5-infected animals. PMID:27224314
Moshgabadi, Noushin; Galli, Rick A; Daly, Amelia C; Ko, Sze Mun Shirley; Westgard, Tayla E; Bulpitt, Ashley F; Shackleton, Christopher R
2015-10-01
Anti-HIV-1 IgM antibody is an important immunoassay target for early HIV antibody detection. The objective of this study is to determine if the early HIV antibody sensitivity of the 60s INSTI test is due to detection of anti-HIV-1 IgM in addition to IgG. To demonstrate HIV gp41 IgM antibody capture by the INSTI HIV-1 gp41 recombinant antigen, an HIV-IgM ELISA was conducted with commercial HIV-1 seroconversion samples. To demonstrate that the INSTI dye-labelled Protein A-based colour developer (CD) has affinity to human IgM, commercial preparations of purified human immunoglobulins (IgM, IgD, IgA, IgE, and IgG) were blotted onto nitrocellulose (NC) and probed with the CD to observe spot development. To determine that INSTI is able to detect anti-HIV-1 IgM antibody, early seroconversion samples, were tested for reduced INSTI test spot intensity following IgM removal. The gp41-based HIV-IgM ELISA results for 6 early seroconversion samples that were INSTI positive determined that the assay signal was due to anti-HIV-1 IgM antibody capture by the immobilised gp41 antigen. The dye-labelled Protein-A used in the INSTI CD produced distinct spots for purified IgM, IgA, and IgG blotted on the NC membrane. Following IgM removal from 21HIV-1 positive seroconversion samples with known or undetermined anti-HIV-1 IgM levels that were western blot negative or indeterminate, all samples had significantly reduced INSTI test spot intensity. The INSTI HIV-1/HIV-2 Antibody Test is shown to detect anti-HIV-1 IgM antibodies in early HIV infection which enhances its utility in early HIV diagnosis. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.
Real-time biochemical assay telemetering system
NASA Technical Reports Server (NTRS)
Kern, Roger G. (Inventor); Mintz, Frederick W. (Inventor); Richards, Gil F. (Inventor); Kidwell, David A. (Inventor)
1999-01-01
The present invention is an apparatus and a method of detecting a chemical released by perspiration, typically through sweat and broadcasting the detection to a receiver. The chemical may be a drug of abuse. The device which is attached to the skin of a subject contains labeled antibodies or label containing microspheres attached to antibodies. The labeled antibodies are bound to solid phase drug via antigen-antibody interaction. These labeled antibodies are displaced from the solid phase support to which they are bound by free drug molecules in the perspiration. These labeled antibodies then migrate through a spacer layer and are trapped by a layer containing a suitable selective binding material. The label is illuminated or excited by a light source and detected by a photodetector. The signal can be recorded, or transmitted to a remote radio monitor.
Bouter, Yvonne; Lopez Noguerola, Jose Socrates; Tucholla, Petra; Crespi, Gabriela A N; Parker, Michael W; Wiltfang, Jens; Miles, Luke A; Bayer, Thomas A
2015-11-01
Solanezumab and Crenezumab are two humanized antibodies targeting Amyloid-β (Aβ) which are currently tested in multiple clinical trials for the prevention of Alzheimer's disease. However, there is a scientific discussion ongoing about the target engagement of these antibodies. Here, we report the immunohistochemical staining profiles of biosimilar antibodies of Solanezumab, Crenezumab and Bapineuzumab in human formalin-fixed, paraffin-embedded tissue and human fresh frozen tissue. Furthermore, we performed a direct comparative immunohistochemistry analysis of the biosimilar versions of the humanized antibodies in different mouse models including 5XFAD, Tg4-42, TBA42, APP/PS1KI, 3xTg. The staining pattern with these humanized antibodies revealed a surprisingly similar profile. All three antibodies detected plaques, cerebral amyloid angiopathy and intraneuronal Aβ in a similar fashion. Remarkably, Solanezumab showed a strong binding affinity to plaques. We also reaffirmed that Bapineuzumab does not recognize N-truncated or modified Aβ, while Solanezumab and Crenezumab do detect N-terminally modified Aβ peptides Aβ4-42 and pyroglutamate Aβ3-42. In addition, we compared the results with the staining pattern of the mouse NT4X antibody that recognizes specifically Aβ4-42 and pyroglutamate Aβ3-42, but not full-length Aβ1-42. In contrast to the biosimilar antibodies of Solanezumab, Crenezumab and Bapineuzumab, the murine NT4X antibody shows a unique target engagement. NT4X does barely cross-react with amyloid plaques in human tissue. It does, however, detect cerebral amyloid angiopathy in human tissue. In Alzheimer mouse models, NT4X detects intraneuronal Aβ and plaques comparable to the humanized antibodies. In conclusion, the biosimilar antibodies Solanezumab, Crenezumab and Bapineuzumab strongly react with amyloid plaques, which are in contrast to the NT4X antibody that hardly recognizes plaques in human tissue. Therefore, NT4X is the first of a new class of therapeutic antibodies.
[Detection of antibodies to adipose tissue cell membranes in human blood].
Bershteĭn, L M; Shemerovskaia, T G; Sofronov, B N; Dil'man, V M
1991-07-01
In serum of some healthy women and patients with fibroadenomatosis of the mammary gland antibodies to the cell membranes of adipocytes were detected. Interconnections between these antibodies and corresponding antigens in blood, on the one hand, and hormonal-metabolic status of probands, on the other hand, were observed. Possible autoimmune origin of phenomenon detected and its relation to the normal and pathological processes in adipose tissue are discussed.
Recombinant antibodies and their use in biosensors.
Zeng, Xiangqun; Shen, Zhihong; Mernaugh, Ray
2012-04-01
Inexpensive, noninvasive immunoassays can be used to quickly detect disease in humans. Immunoassay sensitivity and specificity are decidedly dependent upon high-affinity, antigen-specific antibodies. Antibodies are produced biologically. As such, antibody quality and suitability for use in immunoassays cannot be readily determined or controlled by human intervention. However, the process through which high-quality antibodies can be obtained has been shortened and streamlined by use of genetic engineering and recombinant antibody techniques. Antibodies that traditionally take several months or more to produce when animals are used can now be developed in a few weeks as recombinant antibodies produced in bacteria, yeast, or other cell types. Typically most immunoassays use two or more antibodies or antibody fragments to detect antigens that are indicators of disease. However, a label-free biosensor, for example, a quartz-crystal microbalance (QCM) needs one antibody only. As such, the cost and time needed to design and develop an immunoassay can be substantially reduced if recombinant antibodies and biosensors are used rather than traditional antibody and assay (e.g. enzyme-linked immunosorbant assay, ELISA) methods. Unlike traditional antibodies, recombinant antibodies can be genetically engineered to self-assemble on biosensor surfaces, at high density, and correctly oriented to enhance antigen-binding activity and to increase assay sensitivity, specificity, and stability. Additionally, biosensor surface chemistry and physical and electronic properties can be modified to further increase immunoassay performance above and beyond that obtained by use of traditional methods. This review describes some of the techniques investigators have used to develop highly specific and sensitive, recombinant antibody-based biosensors for detection of antigens in simple or complex biological samples.
NASA Astrophysics Data System (ADS)
Fathil, M. F. M.; Arshad, M. K. Md; Gopinath, Subash C. B.; Adzhri, R.; Ruslinda, A. R.; Hashim, U.
2017-03-01
This paper presents preparation and characterization of conventional enzyme-linked immunosorbent assay (ELISA) for cardiac troponin detection to determine the selectivity of the cardiac troponin monoclonal antibodies. Monoclonal antibodies, used to capture and bind the targets in this experiment, are cTnI monoclonal antibody (MAb-cTnI) and cTnT monoclonal antibody (MAb-cTnT), while both cardiac troponin I (cTnI) and T (cTnT) are used as targets. ELISA is performed inside two microtiter plates for MAb-cTnI and MAb-cTnT. For each plate, monoclonal antibodies are tested by various concentrations of cTnI and cTnT ranging from 0-6400 µg/l. The binding selectivity and level of detection between monoclonal antibodies and antigen are determined through visual observation based on the color change inside each well on the plate. ELISA reader is further used to quantitatively measured the optical density of the color changes, thus produced more accurate reading. The results from this experiment are utilized to justify the use of these monoclonal antibodies as bio-receptors for cardiac troponin detection by using field-effect transistor (FET)-based biosensors coupled with substrate-gate in the future.
Chee, Y C
1983-01-01
'Total antinuclear antibody' (ANF) is detected by the fluorescent antinuclear antibody technique which is a screening test, positive in 99% of systemic lupus erythematosus (SLE) sera. The LE factor (positive in 75% of SLE sera), like the anti-DNA antibody, is an antinuclear antibody but directed against DNA-histone. ANF-negative SLE is a clinical entity with absence of these antibodies. A false negative ANF, in the presence of high titre anti-DNA antibody and/or LE cells, is illustrated in two cases of SLE. Postulated mechanisms for this phenomenon are interference in ANF detection by rheumatoid factor, and the prozone effect on the immunofluorescent tests.
Erlanger, B.F.; Chen, B.X.
1997-07-22
The subject invention provides an antibody which specifically binds to the product of a reaction between a labeling substance and a substrate. The subject invention also provides a method of making an immunogen used to produce the antibody of the subject invention. The invention further provides methods of using the subject antibody for detecting an antigen of interest in a sample, for example detecting a protein comprising an amino acid sequence of interest and detecting a nucleic acid molecule comprising a nucleic acid sequence of interest. 8 figs.
Erlanger, Bernard F.; Chen, Bi-Xing
1997-01-01
The subject invention provides an antibody which specifically binds to the product of a reaction between a labeling substance and a substrate. The subject invention also provides a method of making an immunogen used to produce the antibody of the subject invention. The invention further provides methods of using the subject antibody for detecting an antigen of interest in a sample, for example detecting a protein comprising an amino acid sequence of interest and detecting a nucleic acid molecule comprising a nucleic acid sequence of interest.
Du Plessis, D H; Van Wyngaardt, W; Romito, M; Du Plessis, M; Maree, S
1999-03-01
An indirect sandwich ELISA that can detect as little as 8 ng of African horsesickness virus (AHSV) was developed. Viral antigen was captured from suspension using an immobilized monoclonal antibody specific for an epitope on VP7, a protein that is a major constituent of the virus core. Egg-yolk derived chicken IgY directed against AHSV (serotype 3) was used as the secondary antibody. Since IgY and mouse IgG do not cross-react serologically, the secondary antibody was not labelled, but was instead detected with enzyme-coupled sheep antibodies directed against avian immunoglobulins. The assay recognized all nine AHSV serotypes, but not the Cascara isolate of equine encephalosis virus, a related orbivirus that also infects horses. In addition to being able to detect and quantify whole AHSV, the ELISA could show the presence of VP7 produced by recombinant baculoviruses.
Staroverov, Sergey A; Volkov, Alexei A; Fomin, Alexander S; Laskavuy, Vladislav N; Mezhennyy, Pavel V; Kozlov, Sergey V; Larionov, Sergey V; Fedorov, Michael V; Dykman, Lev A; Guliy, Olga I
2015-01-01
Mini-antibodies that have specific ferritin response have been produced for the first time using sheep's phage libraries (Griffin.1, Medical Research Council, Cambridge, UK). Produced phage antibodies were used for the first time for the development of diagnostic test kits for ferritin detection in the blood of cattle. The immunodot assay with secondary biospecific labeling is suggested as means of ferritin detection in cow blood serum (antiferritin phage antibodies and rabbit antiphage antibodies conjugated with different labels). Сolloidal gold, gold nanoshells, and horse reddish peroxidase used as labels have shown a similar response while detecting concentration of ferritin (0.2 mg/mL). It is shown that the method of solid-phase immunoassay with a visual view of the results allows determination of the minimum concentration of ferritin in the blood of cows at 0.225 g/mL.
Serodiagnosis of parasitic diseases.
Maddison, S E
1991-01-01
In this review on serodiagnosis of parasitic diseases, antibody detection, antigen detection, use of monoclonal antibodies in parasitic serodiagnosis, molecular biological technology, and skin tests are discussed. The focus at the Centers for Disease Control on developing improved antigens, a truly quantitative FAST-enzyme-linked immunosorbent assay, and the very specific immunoblot assays for antibody detection is highlighted. The last two assays are suitable for field studies. Identification of patient response in terms of immunoglobulin class or immunoglobulin G subclass isotypes or both is discussed. Immunoglobulin isotypes may asist in defining the stage of some diseases. In other instances, use of a particular anti-isotype conjugate may increase the specificity of the assay. Monoclonal antibodies have played important roles in antigen purification and identification, in competitive antibody assays with increased sensitivity and specificity, and in assays for antigen detection in serum, body fluids, or excreta. Molecular biological technology has allowed significant advances in the production of defined parasitic serodiagnostic antigens. PMID:1747862
Laitinen, Olli H; Svedin, Emma; Kapell, Sebastian; Hankaniemi, Minna M; Larsson, Pär G; Domsgen, Erna; Stone, Virginia M; Määttä, Juha A E; Hyöty, Heikki; Hytönen, Vesa P; Flodström-Tullberg, Malin
2018-05-01
Enteroviruses (EVs), such as the Coxsackie B-viruses (CVBs), are common human pathogens, which can cause severe diseases including meningitis, myocarditis and neonatal sepsis. EVs encode two proteases (2A pro and 3C pro ), which perform the proteolytic cleavage of the CVB polyprotein and also cleave host cell proteins to facilitate viral replication. The 2A pro cause direct damage to the infected heart and tools to investigate 2A pro and 3C pro expression may contribute new knowledge on virus-induced pathologies. Here, we developed new antibodies to CVB-encoded 2A pro and 3C pro ; Two monoclonal 2A pro antibodies and one 3C pro antibody were produced. Using cells infected with selected viruses belonging to the EV A, B and C species and immunocytochemistry, we demonstrate that the 3C pro antibody detects all of the EV species B (EV-B) viruses tested and that the 2A pro antibody detects all EV-B viruses apart from Echovirus 9. We furthermore show that the new antibodies work in Western blotting, immunocyto- and immunohistochemistry, and flow cytometry to detect CVBs. Confocal microscopy demonstrated the expression kinetics of 2A pro and 3C pro , and revealed a preferential cytosolic localization of the proteases in CVB3 infected cells. In summary, the new antibodies detect proteases that belong to EV species B in cells and tissue using multiple applications. Copyright © 2018 Elsevier B.V. All rights reserved.
Funari, Riccardo; Della Ventura, Bartolomeo; Schiavo, Luigi; Esposito, Rosario; Altucci, Carlo; Velotta, Raffaele
2013-07-02
Photonic immobilization technique (PIT) has been used to develop an immunosensor for the detection of parathion. An antibody solution has been activated by breaking the disulfide bridge in the triad Trp/Cys-Cys through absorption of ultrashort UV laser pulses. The free thiol groups so produced interact with gold lamina making the antibody oriented upside, that is, with its variable parts exposed to the environment, thereby greatly increasing the detection efficiency. PIT has been applied to anchor polyclonal antiparathion antibodies to the gold electrode of a Quartz Crystal Microbalance (QCM) giving rise to very high detection sensitivity once the parathion is made heavier by complexion with BSA (bovine serum albumin), this latter step only required by the mass based transducer used in this case. The comparison of the sensor response with irradiated antibodies against different analytes shows that the high degree of antibody specificity is not affected by PIT nor is it by the complexion of parathion with BSA. These results pave the way to important applications in biosensing, since the widespread occurrence of the Trp/Cys-Cys residues triads in proteins make our procedure very general and effective to detect light analytes.
de Kretser, T A; Thorne, H J; Jacobs, D J; Jose, D G
1985-09-01
A monoclonal antibody, designated OM-1, was raised against ovarian serous papillary cystadenocarcinoma (stage IV) cells. This antibody was found to react strongly with primary and metastatic ovarian serous cystadenocarcinomas and endometrioid carcinomas but the antigen detected was either absent or at very low levels in ovarian mucinous adenocarcinomas, clear cell carcinomas, benign serous and mucinous cystadenomas and Brenner tumours. The OM-1 antibody gave no detectable reaction with 93 other human tumours, including examples of breast and colon adenocarcinomas. In normal tissues the OM-1 antibody reacted with normal sebaceous gland cells, lung type II pneumocytes and placental syncytial trophoblasts. In the normal ovary OM-1 reactivity was confined to extremely weak staining of the surface epithelium. No reaction with any other ovarian cell type could be detected. No evidence of reaction with other normal cell populations present in 24 adult and seven foetal tissues was found. The antigen detected is compared with other ovarian tumour-associated antigens. The OM-1 antibody is likely to prove of value in the detection and diagnosis of ovarian carcinoma.
Construction and Potential Applications of Biosensors for Proteins in Clinical Laboratory Diagnosis
Liu, Xuan
2017-01-01
Biosensors for proteins have shown attractive advantages compared to traditional techniques in clinical laboratory diagnosis. In virtue of modern fabrication modes and detection techniques, various immunosensing platforms have been reported on basis of the specific recognition between antigen-antibody pairs. In addition to profit from the development of nanotechnology and molecular biology, diverse fabrication and signal amplification strategies have been designed for detection of protein antigens, which has led to great achievements in fast quantitative and simultaneous testing with extremely high sensitivity and specificity. Besides antigens, determination of antibodies also possesses great significance for clinical laboratory diagnosis. In this review, we will categorize recent immunosensors for proteins by different detection techniques. The basic conception of detection techniques, sensing mechanisms, and the relevant signal amplification strategies are introduced. Since antibodies and antigens have an equal position to each other in immunosensing, all biosensing strategies for antigens can be extended to antibodies under appropriate optimizations. Biosensors for antibodies are summarized, focusing on potential applications in clinical laboratory diagnosis, such as a series of biomarkers for infectious diseases and autoimmune diseases, and an evaluation of vaccine immunity. The excellent performances of these biosensors provide a prospective space for future antibody-detection-based disease serodiagnosis. PMID:29207528
Construction and Potential Applications of Biosensors for Proteins in Clinical Laboratory Diagnosis.
Liu, Xuan; Jiang, Hui
2017-12-04
Biosensors for proteins have shown attractive advantages compared to traditional techniques in clinical laboratory diagnosis. In virtue of modern fabrication modes and detection techniques, various immunosensing platforms have been reported on basis of the specific recognition between antigen-antibody pairs. In addition to profit from the development of nanotechnology and molecular biology, diverse fabrication and signal amplification strategies have been designed for detection of protein antigens, which has led to great achievements in fast quantitative and simultaneous testing with extremely high sensitivity and specificity. Besides antigens, determination of antibodies also possesses great significance for clinical laboratory diagnosis. In this review, we will categorize recent immunosensors for proteins by different detection techniques. The basic conception of detection techniques, sensing mechanisms, and the relevant signal amplification strategies are introduced. Since antibodies and antigens have an equal position to each other in immunosensing, all biosensing strategies for antigens can be extended to antibodies under appropriate optimizations. Biosensors for antibodies are summarized, focusing on potential applications in clinical laboratory diagnosis, such as a series of biomarkers for infectious diseases and autoimmune diseases, and an evaluation of vaccine immunity. The excellent performances of these biosensors provide a prospective space for future antibody-detection-based disease serodiagnosis.
Radioimmunoassays of hidden viral antigens
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neurath, A.R.; Strick, N.; Baker, L.
1982-07-01
Antigens corresponding to infectious agents may be present in biological specimens only in a cryptic form bound to antibodies and, thus, may elude detection. We describe a solid-phase technique for separation of antigens from antibodies. Immune complexes are precipitated from serum by polyethylene glycol, dissociated with NaSCN, and adsorbed onto nitrocellulose or polystyrene supports. Antigens remain topographically separated from antibodies after removal of NaSCN and can be detected with radiolabeled antibodies. Genomes from viruses immobilized on nitrocellulose can be identified by nucleic acid hybridization. Nanogram quantities of sequestered hepatitis B surface and core antigens and picogram amounts of hepatitis Bmore » virus DNA were detected. Antibody-bound adenovirus, herpesvirus, and measles virus antigens were discerned by the procedure.« less
CMV antibody tests ... never been infected with CMV have no detectable antibodies to CMV. Normal value ranges may vary slightly ... The presence of antibodies to CMV indicates a current or past ... CMV. If the number of antibodies (called the antibody titer) ...
Asambe, A; Sackey, A K B; Tekdek, L B
2018-03-01
This study investigated the prevalence of African swine fever virus (ASFV) and classical swine fever virus (CSFV) antibodies in pigs in Benue State, Nigeria. Serum samples were collected from a total of 460 pigs, including 416 from 74 piggeries and 44 from Makurdi slaughter slab. The samples were analysed using indirect enzyme-linked immunosorbent assay (ELISA) test kit to detect the presence of ASFV antibodies, while competitive ELISA test kit was used to detect antibodies to CSFV. Our findings showed a total ASF prevalence of 13 (2.8%), while prevalences of 7 (1.7%) and 6 (13.6%) were observed in piggeries and in Makurdi slaughter slab, respectively. However, no CSFV antibody sera were detected in this study. Relatively higher ASFV antibody-positive pigs were detected in the slaughter slab than in piggeries. The difference in prevalence of ASF between the two locations was significantly associated (p = 0.017). These findings suggest the presence of ASFV antibody-positive pig in Benue State, Nigeria. Continuous surveillance and monitoring of these diseases among pigs in Nigeria to prevent any fulminating outbreak are recommended.
Sluvko, A L
1976-10-01
Comparative data on production of complement-binding and hemagglutinating antibodies in the process of the antigenic effect of benzylpenicillin under experimental conditions are presented. 30 rabbit antisera and 3 sera of intact animals were studied. The hemagglutinating antibodies were determined in 19 antisera, high and reliable titers of the antipenicillin hemagglutinating antibodies being found only in 8 antisera. The antipenicillin complement-binding antibodies using complex antibiotic antibodies were also found in 19 antisera. The process of antibody production was more pronounced in the complement-binding reaction (CBR). Both types of the antibodies were detected simultaneously in 14 antisera. It is concluded that the CBR with the use of the penicillin complex antigenes on the stroma of the erythrocytes and in combination with the blood serum is a rather sensitive reaction for detection of antipenicillin antibodies.
Design of a sensor for the blood AB0 group antibodies detection
NASA Astrophysics Data System (ADS)
Kolesov, D. V.; Kiselev, G. A.; Moiseev, M. A.; Kudrinskiy, A. A.; Yaminskiy, I. V.
2012-02-01
Control the content of the blood group antibodies in the plasma of the recipient is an important task in modern transplantation. In this paper we proposed to use micromechanical cantilever sensors for detection of the low concentrations of AB0 blood group antibodies in serum. The technique of chemical modification of cantilever surface to create the receptor layer was developed. The apparatus, which provides data acquisition from multiple microconsoles simultaneously was created. We carried out experiments by the detection in a solution the β antibodies with a concentration of 300 times less than the native content of antibodies in the blood. Change in surface stress due to formation of antigen-antibody complexes on the cantilever surface was 0.075 N/m. The resulting lateral strain, apparently, induced by repulsion between the complexes during the sorption of antibodies in layer of antigens, immobilized on the surface. The possibility of regeneration of sensory layer for repeated measurements was shown.
Waner, T; Mazar, S; Nachmias, E; Keren-Kornblatt, E; Harrus, S
2003-05-10
A dot ELISA for the detection of immunoglobulin M (IgM) antibodies to canine distemper virus (CDC) and canine parvovirus (CPV) was assessed. The titres of IgM antibodies to CDV and CPV in 100 dogs were measured by the Immunocomb ELISA kit and compared with the results derived from the immunofluorescence assay (IFA). There was a strong correlation between the results of the dot ELISA technique and the IFA (P < 0.001). The dot ELISA kit was also used to assess the changes in the levels of immunoglobulin G (IgG) and IgM antibodies to CPV and CDV in 10 puppies vaccinated with a polyvalent vaccine. High levels of IgM antibodies to CPV were first detected seven days after they were vaccinated, and after nine days all the pups had high titres of IgG antibodies to CPV. High levels of IgM antibodies to CDV were detected after nine days and the highest average titres were recorded after 12 days. IgG antibodies to CDV were present from nine days after vaccination.
[Myositis-specific autoantibodies].
Gran, Jan Tore; Molberg, Øyvind; Dobloug, Gerd Cecilie; Andersson, Helena; Taraldsrud, Eli; Scheie, David
2009-08-27
Myositis-specific antibodies (MSA) are autoantibodies that are almost exclusively detected in idiopathic inflammatory myopathies (IIM). This article provides an overview of these autoantibodies and how they can be used clinically to identify subgroups of IIM. The article is based on a non-systematic literature review and our own experience. MSA can be detected in up to 50 % of patients with IIM. Patients with anti-synthetase antibodies have a constellation of clinical findings termed "the anti-synthetase syndrome", in which interstitial lung disease dominates the clinical picture. Anti-Mi2 antibodies is another myositis-specific antibody. Patients with anti-Mi2 antibodies often have classical dermatomyositis, while the anti-SRP antibody identifies patients with severe myopathy, poor response to treatment with corticosteroids and histological findings of muscle cell necrosis - often lacking inflammatory infiltrates. The newly detected anti-CADMp140 appears to be associated with amyopathic or hypomyopathic dermatomyositis, previously called dermatomyositis sine myositis. Anti-p155 antibodies are most often found in patients who also have cancer. Myositis-specific antibodies may be useful for identification of clinical subgroups of IIM and can thereby affect the choice of medical treatment.
NASA Astrophysics Data System (ADS)
Baqué, M.; Dobrijevic, M.; Le Postollec, A.; Moreau, T.; Faye, C.; Vigier, F.; Incerti, S.; Coussot, G.; Caron, J.; Vandenabeele-Trambouze, O.
2017-01-01
Several instruments based on immunoassay techniques have been proposed for life-detection experiments in the framework of planetary exploration but few experiments have been conducted so far to test the resistance of antibodies against cosmic ray particles. We present several irradiation experiments carried out on both grafted and free antibodies for different types of incident particles (protons, neutrons, electrons and 12C) at different energies (between 9 MeV and 50 MeV) and different fluences. No loss of antibodies activity was detected for the whole set of experiments except when considering protons with energy between 20 and 30 MeV (on free and grafted antibodies) and fluences much greater than expected for a typical planetary mission to Mars for instance. Our results on grafted antibodies suggest that biochip-based instruments must be carefully designed according to the expected radiation environment for a given mission. In particular, a surface density of antibodies much larger than the expected proton fluence would prevent significant loss of antibodies activity and thus assuring a successful detection.
Handali, Sukwan; Klarman, Molly; Gaspard, Amanda N; Dong, X Fan; Laborde, Ronald; Noh, John; Lee, Yeuk-Mui; Rodriguez, Silvia; Gonzalez, Armando E; Garcia, Hector H; Gilman, Robert H; Tsang, Victor C W; Wilkins, Patricia P
2010-04-01
Taeniasis/cysticercosis caused by Taenia solium is a frequent parasitic infection of the human brain in most of the world. Rapid and simple screening tools to identify taeniasis and cysticercosis cases are needed for control programs, mostly to identify tapeworm carriers which are the source of infection and need to be treated, or as tools for point-of-care case detection or confirmation. These screening assays should be affordable, reliable, rapid, and easy to perform. Immunochromatographic tests meet these criteria. To demonstrate proof of principle, we developed and evaluated two magnetic immunochromatographic tests (MICTs) for detection of human Taenia solium taeniasis antibodies (ES33-MICT) and neurocysticercosis antibodies (T24-MICT). These assays detected stage-specific antibodies by using two recombinant proteins, rES33 for detection of taeniasis antibodies and rT24H for detection of cysticercosis antibodies. The sensitivity and specificity of the ES33-MICT to detect taeniasis infections were 94.5% and 96%, respectively, and those of the T24-MICT to detect cases of human cysticercosis with two or more viable brain cysts were 93.9% and 98.9%, respectively. These data provide proof of principle that the ES33- and T24-MICTs provide rapid and suitable methods to identify individuals with taeniasis and cysticercosis.
Monoclonal Antibodies Attached to Carbon Nanotube Transistors for Paclitaxel Detection
NASA Astrophysics Data System (ADS)
Lee, Wonbae; Lau, Calvin; Richardson, Mark; Rajapakse, Arith; Weiss, Gregory; Collins, Philip; UCI, Molecular Biology; Biochemistry Collaboration; UCI, Departments of Physics; Astronomy Collaboration
Paclitaxel is a naturally-occurring pharmaceutical used in numerous cancer treatments, despite its toxic side effects. Partial inhibition of this toxicity has been demonstrated using weakly interacting monoclonal antibodies (3C6 and 8A10), but accurate monitoring of antibody and paclitaxel concentrations remains challenging. Here, single-molecule studies of the kinetics of antibody-paclitaxel interactions have been performed using single-walled carbon nanotube field-effect transistors. The devices were sensitized with single antibody attachments to record the single-molecule binding dynamics of paclitaxel. This label-free technique recorded a range of dynamic interactions between the antibody and paclitaxel, and it provided sensitive paclitaxel detection for pM to nM concentrations. Measurements with two different antibodies suggest ways of extending this working range and uncovering the mechanistic differences among different antibodies.
Kardi, V; Szegletes, E; Perényi, T; Pergel, I; Smal, Z
1990-01-01
A double antibody sandwich enzyme-linked immunosorbent assay (ELISA) was developed for measuring Aujeszky's disease virus (ADV) antigen concentration and an inhibition technique based on the former was developed for detection of antibodies to ADV. The results were checked by determining the cytopathic and serum neutralization titres. The correlation was satisfactory in both cases, with correlation coefficients above 0.8. When measuring ADV antigen concentration, the lower limit of detection was 10(3) TCID 50/0.2 ml. The sensitivity of ELISA in detecting antibodies to ADV was found to be superior to that of the serum neutralization test and, thus, enabled the testing of rabbit and guinea-pig sera.
NASA Astrophysics Data System (ADS)
Samuelsen, Simone V.; Solov'Yov, Ilia A.; Balboni, Imelda M.; Mellins, Elizabeth; Nielsen, Christoffer Tandrup; Heegaard, Niels H. H.; Astakhova, Kira
2016-10-01
New techniques to detect and quantify antibodies to nucleic acids would provide a significant advance over current methods, which often lack specificity. We investigate the potential of novel antigens containing locked nucleic acids (LNAs) as targets for antibodies. Particularly, employing molecular dynamics we predict optimal nucleotide composition for targeting DNA-binding antibodies. As a proof of concept, we address a problem of detecting anti-DNA antibodies that are characteristic of systemic lupus erythematosus, a chronic autoimmune disease with multiple manifestations. We test the best oligonucleotide binders in surface plasmon resonance studies to analyze binding and kinetic aspects of interactions between antigens and target DNA. These DNA and LNA/DNA sequences showed improved binding in enzyme-linked immunosorbent assay using human samples of pediatric lupus patients. Our results suggest that the novel method is a promising tool to create antigens for research and point-of-care monitoring of anti-DNA antibodies.
Granoff, Dan M.; Costa, Isabella; Konar, Monica; Giuntini, Serena; Van Rompay, Koen K. A.; Beernink, Peter T.
2015-01-01
Background. The meningococcal vaccine antigen, factor H (FH)–binding protein (FHbp), binds human complement FH. In human FH transgenic mice, binding decreased protective antibody responses. Methods. To investigate the effect of primate FH binding, we immunized rhesus macaques with a 4-component serogroup B vaccine (4CMenB). Serum FH in 6 animals bound strongly to FHbp (FHbp-FHhigh) and, in 6 animals, bound weakly to FHbp (FHbp-FHlow). Results. There were no significant differences between the respective serum bactericidal responses of the 2 groups against meningococcal strains susceptible to antibody to the NadA or PorA vaccine antigens. In contrast, anti-FHbp bactericidal titers were 2-fold lower in FHbp-FHhigh macaques against a strain with an exact FHbp match to the vaccine (P = .08) and were ≥4-fold lower against 4 mutants with other FHbp sequence variants (P ≤ .005, compared with FHbp-FHlow macaques). Unexpectedly, postimmunization sera from all 12 macaques enhanced FH binding to meningococci. In contrast, serum anti-FHbp antibodies elicited by 4CMenB in mice whose mouse FH did not bind to the vaccine antigen inhibited FH binding. Conclusions. Binding of FH to FHbp decreases protective anti-FHbp antibody responses of macaques to 4CMenB. Even low levels of FH binding skew the antibody repertoire to FHbp epitopes outside of the FH-binding site, which enhance FH binding. PMID:25676468
de Fockert, Jan W; Bremner, Andrew J
2011-12-01
An unexpected stimulus often remains unnoticed if attention is focused elsewhere. This inattentional blindness has been shown to be increased under conditions of high memory load. Here we show that increasing working memory load can also have the opposite effect of reducing inattentional blindness (i.e., improving stimulus detection) if stimulus detection is competing for attention with a concurrent visual task. Participants were required to judge which of two lines was the longer while holding in working memory either one digit (low load) or six digits (high load). An unexpected visual stimulus was presented once alongside the line judgment task. Detection of the unexpected stimulus was significantly improved under conditions of higher working memory load. This improvement in performance prompts the striking conclusion that an effect of cognitive load is to increase attentional spread, thereby enhancing our ability to detect perceptual stimuli to which we would normally be inattentionally blind under less taxing cognitive conditions. We discuss the implications of these findings for our understanding of the relationship between working memory and selective attention. Copyright © 2011 Elsevier B.V. All rights reserved.
Walpurgis, Katja; Thomas, Andreas; Schänzer, Wilhelm; Thevis, Mario
2016-02-01
Myostatin is a key regulator of skeletal muscle growth and inhibition of its signaling pathway results in an increased muscle mass and function. The aim of this study was to develop a qualitative detection assay for myostatin-neutralizing antibodies for doping control purposes by using immunological approaches. To detect different types of myostatin-neutralizing antibodies irrespective of their amino acid sequence, an immunological assay specific for antibodies directed against myostatin and having a human Fc domain was established. Affinity purification and Western blotting strategies were combined to allow extracting and identifying relevant analytes from 200 μL of plasma/serum in a non-targeted approach. The assay was characterized regarding specificity, linearity, precision, robustness, and recovery. The assay was found to be highly specific, robust, and linear from 0.1 to 1 μg/mL. The precision was successfully specified at three different concentrations and the recovery of the affinity purification was 58%. Within this study, an immunological detection assay for myostatin-neutralizing antibodies present in plasma/serum specimens was developed and successfully characterized. The presented approach can easily be modified to include other therapeutic antibodies and serves as proof-of-concept for the detection of antibody-based myostatin inhibitors in doping control samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
EDRN Biomarker Reference Lab: Pacific Northwest National Laboratory — EDRN Public Portal
The purpose of this project is to develop antibody microarrays incorporating three major improvements compared to previous antibody microarray platforms, and to produce and disseminate these antibody microarray technologies for the Early Detection Research Network (EDRN) and the research community focusing on early detection, and risk assessment of cancer.
Kim, Eun-Ju; Cheong, Kwang-Myun; Joung, Ha-Kyung; Kim, Bo-Hye; Song, Jae-Young; Cho, In-Soo; Lee, Kyoung-Ki; Shin, Yeun-Kyung
2016-12-30
Infection of cattle with bovine leukemia virus (BLV) has been observed and reported worldwide, including in Korea. The onsite identification of infected cattle would help decreasing and eradicating BLV infections on farms. Here, we present a new immunochromatographic assay that employs monoclonal antibodies (MAbs) for the detection of antibodies against BLV in the field. BLV envelope glycoprotein (gp)51 was expressed in E. coli , and MAbs against recombinant BLV gp51 were generated for the development of an immunochromatographic assay to detect BLV antibodies in cattle. The sensitivity and specificity of the assay were determined by comparing these results with those obtained from a standard enzyme linked immunosorbent assay (ELISA). A total of 160 bovine sera were used to evaluate the new immunochromatographic assay. Using ELISA as a reference standard, the relative specificity and sensitivity of this assay were determined to be 94.7% and 98%, respectively. Because of its high sensitivity and specificity, this BLV antibody detection assay would be suitable for the onsite identification of BLV infection in the field.
Sedykh, Sergey E; Lekchnov, Evgenii A; Prince, Viktor V; Buneva, Valentina N; Nevinsky, Georgy A
2016-10-20
In the classic paradigm, immunoglobulins represent products of clonal B cell populations, each producing antibodies recognizing a single antigen (monospecific). There is a common belief that IgGs in mammalian biological fluids are monospecific molecules having stable structures and two identical antigen-binding sites. But the issue concerning the possibility of exchange by HL-fragments between the antibody molecules in human blood is still unexplored. Different physico-chemical and immunological methods for analysis of half-molecule exchange between human blood IgGs were used. Using eighteen blood samples of healthy humans we have shown unexpected results for the first time: blood antibodies undergo extensive post-transcriptional half-molecule exchange and IgG pools on average consist of 62.4 ± 6.5% IgGs containing kappa light chains (kappa-kappa-IgGs), 29.8.6 ± 5.4% lambda light chains (lambda-lambda-IgGs), and 8.8 ± 2.7% (range 2.6-16.8%) IgGs containing both kappa- and lambda-light chains. Kappa-kappa-IgGs and lambda-lambda-IgGs contained on average (%): IgG1 (36.0 and 32.3), IgG2 (50.9 and 51.4), IgG3 (9.7 and 9.9), and IgG4 (6.5 and 5.7), while chimeric kappa-lambda-IgGs consisted of (%): 25.5 ± 4.2 IgG1, 50.8 ± 3.9 IgG2, 9.1 ± 2.1 IgG3, and 14.5 ± 2.2 IgG4. Our unexpected data are indicative of the possibility of half-molecule exchange between blood IgGs of various subclasses, raised against different antigens. The existence of blood chimeric bifunctional IgGs with different binding sites destroys the classic paradigm. Due to the phenomenon of polyspecificity and cross-reactivity of bifunctional IgGs containing HL-fragments of different types to different antigens, such IgGs may be important in human blood for widening their different biological functions.
Shankaran, Dhesingh Ravi; Kawaguchi, Toshikazu; Kim, Sook Jin; Matsumoto, Kiyoshi; Toko, Kiyoshi; Miura, Norio
2006-11-01
Detection of TNT is an important environmental and security concern all over the world. We herein report the performance and comparison of four immunoassays for rapid and label-free detection of 2,4,6-trinitrotoluene (TNT) based on surface plasmon resonance (SPR). The immunosensor surface was constructed by immobilization of a home-made 2,4,6-trinitrophenyl-keyhole limpet hemocyanin (TNPh-KLH) conjugate onto an SPR gold surface by simple physical adsorption within 10 min. The immunoreaction of the TNPh-KLH conjugate with four different antibodies, namely, monoclonal anti-TNT antibody (M-TNT Ab), monoclonal anti-trinitrophenol antibody (M-TNP Ab), polyclonal anti-trinitrophenyl antibody (P-TNPh Ab), and polyclonal anti-TNP antibody (P-TNP Ab), was studied by SPR. The principle of indirect competitive immunoreaction was employed for quantification of TNT. Among the four antibodies, the P-TNPh Ab prepared by our group showed highest sensitivity with a detection limit of 0.002 ng/mL (2 ppt) TNT. The lowest detection limits observed with other commercial antibodies were 0.008 ng/mL (8 ppt), 0.25 ng/mL (250 ppt), and 40 ng/mL (ppb) for M-TNT Ab, P-TNP Ab, and M-TNP Ab, respectively, in the similar assay format. The concentration of the conjugate and the antibodies were optimized for use in the immunoassay. The response time for an immunoreaction was 36 s and a single immunocycle could be done within 2 min, including the sensor surface regeneration using pepsin solution. In addition to the quantification of TNT, all immunoassays were evaluated for robustness and cross-reactivity towards several TNT analogs.
Subtype-Specific Influenza A Virus Antibodies in Canada Geese (Branta canadensis)
Kistler, Whitney M.; Stallknecht, David E.; DeLiberto, Thomas J.; Van Why, Kyle; Yabsley, Michael J.
2015-01-01
Historically, surveillance for influenza A viruses (IAVs) in wild birds has relied on viral detection assays. This was largely due to poor performance of serological assays in wild birds; however, recently developed commercial serological assays have improved the ability to detect IAV antibodies in wild birds. Serological surveillance for IAV antibodies in Canada geese (Branta canadensis) has shown that, despite a low prevalence of virus isolations, Canada geese are frequently exposed to IAVs and that exposure increases with latitude, which follows virus isolation prevalence patterns observed in dabbling ducks. The objectives of this study were to further evaluate IAV antibodies in Canada geese using a subtype-specific serological assay to determine if Canada geese are exposed to subtypes that commonly circulate in dabbling ducks. We collected serum samples from Canada geese in Minnesota, New Jersey, Pennsylvania, and Wisconsin and tested for antibodies to IAVs using a blocking ELISA. Positive samples were further tested by hemagglutination inhibition for 10 hemagglutinin IAV subtypes (H1–H10). Overall, we detected antibodies to NP in 24% (714/2,919) of geese. Antibodies to H3, H4, H5, and H6 subtypes predominated, with H5 being detected most frequently. A decrease in H5 HI antibody prevalence and titers was observed from 2009 to 2012. We also detected similar exposure pattern in Canada geese from New Jersey, Minnesota, Washington and Wisconsin. Based on the published literature, H3, H4, and H6 viruses are the most commonly reported IAVs from dabbling ducks. These results indicate that Canada geese also are frequently exposed to viruses of the same HA subtypes; however, the high prevalence of antibodies to H5 viruses was not expected as H5 IAVs are generally not well represented in reported isolates from ducks. PMID:25845755
Juhl, David; Marget, Matthias; Hallensleben, Michael; Görg, Siegfried; Ziemann, Malte
2017-03-01
Soon, a virtual crossmatch shall replace the complement-dependent cytotoxicity (CDC) allocation crossmatch in the Eurotransplant region. To prevent positive CDC-crossmatches in the recipient centre, careful definition of unacceptable antigens is necessary. For highly sensitized patients, this is difficult by CDC alone. Assignment of all antibodies detected by sensitive assays, however, could prevent organ allocation. To assess the usefulness of the Luminex C1q-assay to prevent positive CDC-crossmatches, all CDC-crossmatches performed prior to deceased kidney transplantation in a 16-month-period were reviewed. Sera causing positive crossmatches were investigated by the C1q-assay. 31 out of 1432 crossmatches (2.2%) were positive. Sera involved in 26 positive crossmatches were available. C1q-binding donor-specific antibodies were detected in 19 sera (73.1%). The other sera were from recipients without any HLA antibodies detectable by CDC or common solid phase assays. Three patients had known Non-HLA antibodies causing positive CDC-results. Four crossmatches were only weak positive. Therefore, avoidance of donors with HLA antigens against whom C1q-binding antibodies were detected would have prevented all positive crossmatches due to HLA antibodies. Provided that all HLA specificities against which antibodies are detected by the Luminex C1q-assay are considered as unacceptable antigens, CDC-crossmatches prior to transplantation might safely be omitted in many patients. They should be maintained in highly immunized patients, however, for whom assignment of all C1q-positive antibodies as unacceptable antigens could lead to a significant delay or even prevention of transplantation. Copyright © 2017 Elsevier B.V. All rights reserved.
Nano-particle enhanced impedimetric biosensor for detedtion of foodborne pathogens
NASA Astrophysics Data System (ADS)
Kim, G.; Om, A. S.; Mun, J. H.
2007-03-01
Recent outbreaks of foodborne illness have been increased the need for rapid and sensitive methods for detection of these pathogens. Conventional methods for pathogens detection and identification involve prolonged multiple enrichment steps. Even though some immunological rapid assays are available, these assays still need enrichment steps result in delayed detection. Biosensors have shown great potential for rapid detection of foodborne pathogens. They are capable of direct monitoring the antigen-antibody reactions in real time. Among the biosensors, impedimetric biosensors have been widely adapted as an analysis tool for the study of various biological binding reactions because of their high sensitivity and reagentless operation. In this study a nanoparticle-enhanced impedimetric biosensor for Salmonella enteritidis detection was developed which detected impedance changes caused by the attachment of the cells to the anti-Salmonella antibodies immobilized on interdigitated gold electrodes. Successive immobilization of neutravidin followed by anti-Salmonella antibodies was performed to the sensing area to create a biological detection surface. To enhance the impedance responses generated by antigen-antibody reactions, anti-Salmonella antibody conjugated nanoparticles were introduced on the sensing area. Using a portable impedance analyzer, the impedance across the interdigital electrodes was measured after the series of antigen-antibody bindings. Bacteria cells present in solution attached to capture antibodies and became tethered to the sensor surface. Attached bacteria cells changed the dielectric constant of the media between the electrodes thereby causing a change in measured impedance. Optimum input frequency was determined by analyzing frequency characteristics of the biosensor over ranges of applied frequencies from 10 Hz to 400 Hz. At 100 Hz of input frequency, the biosensor was most sensitive to the changes of the bacteria concentration and this frequency was used for the detection experiments. The biosensor was able to detect 106 CFU/mL in phosphate buffered saline (PBS) with a detection time of 3 minutes. Additional use of nanoparticles significantly enhanced the detection performance. By using the nanoparticles the biosensor could detect 104 CFU/mL of Salmonella enteritidis in PBS and 105 CFU/mL of cells in milk.
A study of autoimmune markers in hepatitis C infection.
Agarwal, N; Handa, R; Acharya, S K; Wali, J P; Dinda, A K; Aggarwal, P
2001-05-01
Hepatitis C virus (HCV) infection is associated with several autoimmune markers. Despite HCV being common in India, no information on this aspect is available. This study was undertaken to ascertain the frequency and clinical significance of autoimmune markers like rheumatoid factor (RF), antinuclear antibodies (ANA), antibodies to double stranded deoxyribonucleic acid (dsDNA), anti neutrophil cytoplasmic antibody (ANCA), anti smooth muscle antibodies (ASMA), anti liver kidney microsomal 1 antibodies (anti LKM1), anti gastric parietal cell antibodies (anti GPCA), anti mitochondrial antibodies (AMA), anti cardiolipin antibodies (ACL) and cryoglobulins in HCV infection and to determine the effect of treatment on these markers. Twenty five patients with chronic hepatitis C and 25 healthy controls were studied. Cryoglobulins were detected by cryoprecipitation, RF by latex agglutination, anti dsDNA and ACL by ELISA while indirect immunofluorescence was used to detect all other autoantibodies. Eighteen patients (72%) demonstrated autoimmune markers. RF, cryoglobulins and anti LKM1 antibodies were the most frequently detected markers (in 32% patients each). ASMA, perinuclear ANCA (pANCA), ANA and anti GPCA were seen in 24, 20, 12 and 4 per cent patients respectively. None of the patients exhibited ACL, AMA or antibodies to dsDNA. No antibodies were detected in healthy controls. Sixty per cent of the patients had rheumatological symptoms. Of the seven patients followed up after treatment with alpha interferon, only two exhibited persistence of RF, while symptoms and other markers disappeared. Rheumatological symptoms and autoimmune markers are common in HCV infection and are usually overlooked. Patients with unexplained joint pains and/or palpable purpura should be screened for HCV. Further studies are needed to delineate fully the link between infection and autoimmunity.
Kamemura, Norio; Tada, Hitomi; Shimojo, Naoki; Morita, Yoshinori; Kohno, Yoichi; Ichioka, Takao; Suzuki, Koichi; Kubota, Kenji; Hiyoshi, Mineyoshi; Kido, Hiroshi
2012-07-01
To design a rational allergy prevention program, it is important to determine whether allergic sensitization starts in utero under the maternal immune system. To investigate the origin of allergen-specific IgE antibodies in cord blood (CB) and maternofetal transfer of immunoglobulins. The levels of food and inhalant allergen-specific IgE, IgA, IgG, and IgG(4) antibodies in CB and maternal blood (MB) from 92 paired neonates and mothers were measured by using a novel allergen microarray of diamond-like-carbon-coated chip, with high-sensitivity detection of allergen-specific antibodies and allergen profiles. The levels of allergen-specific IgE antibodies against food and inhalant allergens and allergen profiles were identical in CB and newborn blood, but the levels and profiles, specifically against inhalant allergens, were different from those in MB. The level of allergen-specific IgA antibodies was below the detection levels in CB despite clear detection in MB. Therefore, contamination with MB in CB was excluded on the basis of extremely low levels of IgA antibodies in CB and the obvious mismatch of the allergen-specific IgE and IgA profiles between CB and MB. However, the levels of allergen-specific IgG and IgG(4) antibodies and their allergen profiles were almost identical in both MB and CB. Allergen-specific levels of IgE and IgA antibodies and their allergen profiles analyzed by the diamond-like-carbon allergen chip indicate that IgE antibodies in CB are of fetal origin. Food-allergen specific IgE antibodies were detected more often than inhalant-allergen specific IgE antibodies in CB, the reason of which remains unclarified. Copyright © 2012 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All rights reserved.
Characterization of a new chimeric marker vaccine candidate with a mutated antigenic E2-epitope.
Reimann, Ilona; Depner, Klaus; Utke, Katrin; Leifer, Immanuel; Lange, Elke; Beer, Martin
2010-04-21
A new chimeric pestivirus "CP7_E1E2alf_TLA", based on the infectious cDNA of bovine viral diarrhea virus (BVDV) strain CP7, was constructed. The substitution of BVDV E1 and E2 with the respective proteins of classical swine fever (CSF) strain Alfort 187 allows an optimal heterodimerization of E1 and E2 in the chimeric virus, which is beneficial for efficient and authentic virus assembly and growth. In addition, for implementation of E2-based marker diagnostics, the previously described antigenic CSFV-specific TAVSPTTLR epitope was exchanged with the corresponding E2-epitope of BVDV strain CP7. Recombinant virus CP7_E1E2alf_TLA displayed a growth defect, and was not reacting with monoclonal antibodies used in commercial E2 antibody blocking ELISAs. Therefore, efficacy as well as marker properties of CP7_E1E2alf_TLA were investigated in an animal experiment with both a high dose and a low dose vaccine preparation. All CP7_E1E2alf_TLA-vaccinated animals seroconverted until day 28 post-vaccination with neutralizing antibodies. Furthermore, at the day of challenge infection CP7_E1E2alf_TLA-immunized animals showed distinct lower ELISA values in a commercial CSFV E2 antibody test in comparison to the C-strain vaccinated controls. However, E2-ELISA reactivity as well as neutralizing titers were directly connected to the dosage used for vaccination, and only the low dose group had E2-ELISA values below threshold until challenge infection. Following challenge infection with highly virulent CSFV strain Koslov, all vaccinees were protected, however, short-term fever episodes and very limited CSFV genome detection with very low copy numbers could be observed. In conclusion, manipulation of the TAVSPTTLR-epitope within the tested chimeric virus resulted in an slightly reduced efficacy, but the E2 marker properties unexpectedly did not allow a clear differentiation of infected from vaccinated animals in some cases. Copyright 2009 Elsevier B.V. All rights reserved.
Sharp, Michael F; Stephen, Juan N; Kraft, Lukas; Weiss, Thomas; Kamath, Sandip D; Lopata, Andreas L
2015-02-01
Fish are the largest and most diverse group of vertebrates. Fish are also a part of the eight food groups that cause the majority of IgE mediated food reactions. Detection tools for fish allergens are however limited due to the great diversity of fish species, despite fish allergy and its major allergen parvalbumin being well documented. The most commonly studied fish are frequently consumed in North America and Europe. However, much less is known about fish allergens in the Australasian region although fish is widely consumed in this region. A comprehensive phylogenetic analysis was performed of known parvalbumin amino acid sequences to determine possible candidate antigens for new cross-reactive antibodies to be used to detect most fish parvalbumins. Polyclonal rabbit antibodies were raised against parvalbumins from frequently consumed barramundi (Lates calcarifer), basa (Pangasius bocourti), pilchard (Sardinops sagax) and Atlantic salmon (Salmo salar). These were evaluated for cross-reactivity against a panel of 45 fish extracts (raw, heated and canned fish). Anti-barramundi parvalbumin proved to be the most cross-reactive antibody, detecting 87.5% of the 40 species analyzed, followed by anti-pilchard and anti-basa antibody. In contrast the anti-salmon antibody was very specific and only reacted to salmonidae and a few other fish. All analyzed fish species, except mahi mahi, swordfish, yellowfin tuna and all 5 canned fish had parvalbumin detected in raw extracts. However antibody reactivity to many fish was heat liable or susceptible to denaturation, demonstrating that some parvalbumins have most likely conformational epitopes, which lose antibody reactivity after heat treatment. We have demonstrated the generation of highly cross-reactive anti-parvalbumin antibodies that could be used for the detection of allergenic fish parvalbumin in contaminated food products. This cross-reactivity study thus shows processing of fish, especially canning, can have on impact on antibody recognition by ELISA, possibly similar to IgE-binding in vivo. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Parr, M.; Illarionov, R.; Marchenko, Y.; Yakovleva, L.; Nikolaev, B.; Ischenko, A.; Shevtsov, M.
2016-08-01
Switching assay was applied for the detection of antigen-antibody interaction between 70-kDa heat shock protein (Hsp70) and anti-Hsp70 monoclonal antibodies in water solutions using conjugates with magnetic iron oxide nanoparticles (MNPs). Hsp70 is a ubiquitous intracellular protein that plays a crucial role in cancerogenesis and many other pathologies. Detection of the Hsp70 level in the biological fluids might have a prognostic and diagnostic value in clinic. The developed switch assay for the detection of Hsp70 demonstrated high sensitivity for antigen-antibody interaction analysis thus proving its potential for further preclinical and clinical studies.
Abdella, Rana M A; Abdelmoaty, Hatem I; Elsherif, Rasha H; Sayed, Ahmed Mahmoud; Sherif, Nadine Alaa; Gouda, Hisham M; El Lithy, Ahmed; Almohamady, Maged; Abdelbar, Mostafa; Hosni, Ahmed Naguib; Magdy, Ahmed; Ma, Youssef
2015-06-02
To study the prevalence of Chlamydia infection in women with primary and secondary unexplained infertility using ELISA technique for antibody detection and real time, fully automated PCR for antigen detection and to explore its association with circulating antisperm antibodies (ASA). A total of 50 women with unexplained infertility enrolled in this case control study and a control group of 44 infertile women with a known cause of infertility. Endocervical specimens were collected for Chlamydia antigen detection using PCR and serum samples for antibodies detection. Circulating anti-sperm antibodies were detected using sperm antibody Latex Agglutination tests. The overall prevalence of Chlamydial infection in unexplained infertility cases as detected by both ELISA and PCR was 40 % (20/50). The prevalence of current Chlamydial genital infection as detected by real-time PCR was only 6.0 % (3/50); two of which were also IgM positive. Prevalence of ASA was 6.0 % (3/50); all were sero-negative for anti-C.trachomatis IgM and were PCR negative. The incidence of Chlamydial infection in Egyptian patients with unexplained infertility is relatively high. In the setting of fertility investigations; screening for anti. C.trachomatis antibodies using ELISA, and treatment of positive cases should be considered. The presence of circulating ASA does not correlate with the presence of old or current Chlamydia infection in women with unexplained infertility.
Wu, Wenhe; Li, Jun; Pan, Dun; Li, Jiang; Song, Shiping; Rong, Mingge; Li, Zixi; Gao, Jimin; Lu, Jianxin
2014-10-08
Enzyme-linked immunosorbent assay (ELISA) provides a convenient means for the detection of Salmonella enterica serovar Typhimurium (STM), which is important for rapid diagnosis of foodborne pathogens. However, conventional ELISA is limited by antibody-antigen immunoreactions and suffers from poor sensitivity and tedious sample pretreatment. Therefore, development of novel ELISA remains challenging. Herein, we designed a comprehensive strategy for rapid, sensitive, and quantitative detection of STM with high specificity by gold nanoparticle-based enzyme-linked antibody-aptamer sandwich (nano-ELAAS) method. STM was captured and preconcentrated from samples with aptamer-modified magnetic particles, followed by binding with detector antibodies. Then nanoprobes carrying a large amount of reporter antibodies and horseradish peroxidase molecules were used for colorimetric signal amplification. Under the optimized reaction conditions, the nano-ELAAS assay had a quantitative detection range from 1 × 10(3) to 1 × 10(8) CFU mL(-1), a limit of detection of 1 × 10(3) CFU mL(-1), and a selectivity of >10-fold for STM in samples containing other bacteria at higher concentration with an assay time less than 3 h. In addition, the developed nanoprobes were improved in terms of detection range and/or sensitivity when compared with two commercial enzyme-labeled antibody signal reporters. Finally, the nano-ELAAS method was demonstrated to work well in milk samples, a common source of STM contamination.
Chien, Wei Wen; Niogret, Charlène; Jugé, Romain; Lionnard, Loïc; Cornut-Thibaut, Aurélie; Kucharczak, Jérôme; Savina, Ariel; Salles, Gilles; Aouacheria, Abdel
2017-04-01
GA101, also known as obinutuzumab or Gazyva (Gazyvaro), is a glycoengineered type II humanized antibody that targets the CD20 antigen expressed at the surface of B-cells. This novel anti-CD20 antibody is currently assessed in clinical trials with promising results as a single agent or as part of therapeutic combinations for the treatment of B-cell malignancies. Detailed understanding of the mechanisms of GA101-induced cell death is needed to get insight into possible resistance mechanisms occurring in patients. Although multiple in vitro and in vivo mechanisms have been suggested to describe the effects of GA101 on B-cells, currently available data are ambiguous. The aim of our study was to clarify the cellular mechanisms involved in GA101-induced cell death in vitro, and more particularly the respective roles played by lysosomal and mitochondrial membrane permeabilization. Our results confirm previous reports suggesting that GA101 triggers homotypic adhesion and caspase-independent cell death, two processes that are dependent on actin remodeling and involve the production of reactive oxygen species. With respect to lysosomal membrane permeabilization (LMP), our data suggest that lack of specificity of available antibodies directed against cathepsin B may have confounded previously published results, possibly challenging current LMP-driven model of GA101 action mode. Copyright © 2017 Elsevier Ltd. All rights reserved.
Interaction of A1B1 and BRCA1 in the Development of Breast Cancer
2008-03-01
using MCF-7 cellular lysate (Figure 1). In this experiment, BRCA1 was immunoprecipitated with a BRCA1 antibody (Ab2, Oncogene Science) and GammaBind...Sepharose beads (GE Healthcare). AIB1 was detected by immunoblot with an anti-AIB1 antibody (BD Transduction). There was increased association of...EGF-induced tyrosine phosphorylation of EGFR as detected with a phosphotyrosine antibody (Figure 8A). This result was then verified with antibodies
Stanker, Larry H.; Scotcher, Miles C.; Cheng, Luisa; Ching, Kathryn; McGarvey, Jeffery; Hodge, David; Hnasko, Robert
2013-01-01
Botulism is a serious foodborne neuroparalytic disease, caused by botulinum neurotoxin (BoNT), produced by the anaerobic bacterium Clostridium botulinum. Seven toxin serotypes (A – H) have been described. The majority of human cases of botulism are caused by serotypes A and B followed by E and F. We report here a group of serotype B specific monoclonal antibodies (mAbs) capable of binding toxin under physiological conditions. Thus, they serve as capture antibodies for a sandwich (capture) ELISA. The antibodies were generated using recombinant peptide fragments corresponding to the receptor-binding domain of the toxin heavy chain as immunogen. Their binding properties suggest that they bind a complex epitope with dissociation constants (KD’s) for individual antibodies ranging from 10 to 48 × 10−11 M. Assay performance for all possible combinations of capture-detector antibody pairs was evaluated and the antibody pair resulting in the lowest level of detection (L.O.D.), ~20 pg/mL was determined. Toxin was detected in spiked dairy samples with good recoveries at concentrations as low as 0.5 pg/mL and in ground beef samples at levels as low as 2 ng/g. Thus, the sandwich ELISA described here uses mAb for both the capture and detector antibodies (binding different epitopes on the toxin molecule) and readily detects toxin in those food samples tested. PMID:24253240
Stanker, Larry H; Scotcher, Miles C; Cheng, Luisa; Ching, Kathryn; McGarvey, Jeffery; Hodge, David; Hnasko, Robert
2013-11-18
Botulism is a serious foodborne neuroparalytic disease, caused by botulinum neurotoxin (BoNT), produced by the anaerobic bacterium Clostridium botulinum. Seven toxin serotypes (A-H) have been described. The majority of human cases of botulism are caused by serotypes A and B followed by E and F. We report here a group of serotype B specific monoclonal antibodies (mAbs) capable of binding toxin under physiological conditions. Thus, they serve as capture antibodies for a sandwich (capture) ELISA. The antibodies were generated using recombinant peptide fragments corresponding to the receptor-binding domain of the toxin heavy chain as immunogen. Their binding properties suggest that they bind a complex epitope with dissociation constants (KD's) for individual antibodies ranging from 10 to 48 × 10-11 M. Assay performance for all possible combinations of capture-detector antibody pairs was evaluated and the antibody pair resulting in the lowest level of detection (L.O.D.), ~20 pg/mL was determined. Toxin was detected in spiked dairy samples with good recoveries at concentrations as low as 0.5 pg/mL and in ground beef samples at levels as low as 2 ng/g. Thus, the sandwich ELISA described here uses mAb for both the capture and detector antibodies (binding different epitopes on the toxin molecule) and readily detects toxin in those food samples tested.
CSF herpes virus and autoantibody profiles in the evaluation of encephalitis
Linnoila, Jenny J.; Binnicker, Matthew J.; Majed, Masoud; Klein, Christopher J.
2016-01-01
Objective: To report the frequency of coexisting herpes viruses (herpes simplex virus 1 [HSV-1] or HSV-2, varicella zoster virus, Epstein-Barr virus [EBV], cytomegalovirus, or human herpes virus 6 [HHV-6]) and autoantibodies in patients with encephalitis (herpes or autoimmune) in clinical laboratory service. Methods: Three groups were evaluated for herpes viruses and antibodies: group 1—patients whose CSF was positive for a herpes virus by real-time PCR over a period of 6 months; group 2—patients whose CSF was positive for an autoimmune encephalitis–associated antibody over 5 years (e.g., NMDA receptor [NMDA-R] antibody), and the same number of controls without autoimmune/infectious disease; and group 3—incidental autoimmune parainfectious encephalitis cases encountered over 1 year. Results: In group 1, antibodies were detected in 27 of 100 herpes PCR-positive CSF specimens (CSFs), either unclassified neural or nonneural in all but one patient with NMDA-R antibody detected after EBV infection. Antibodies were also detected in 3 of 7 CSFs submitted for repeat PCR testing (unclassified, 2; AMPA receptor, 1). In group 2, herpes viruses were detected in 1 of 77 controls (HHV-6) and 4 of 77 patients with autoimmune encephalitis (EBV, 2; HHV-6, 2); autoantibodies targeted NMDA-R in 3/4 and GABAB-R in 1/4. In group 3, NMDA-R antibody was detected in 7 patients post–HSV-1 encephalitis. Of the remaining 3 patients, 2 had unclassified neural antibodies detected, and one had GABAB-R autoimmunity. Concomitant neoplasms were discovered in 2 patients each from groups 2 and 3. Conclusions: Autoantibodies and herpes virus DNA frequently coexist in encephalitic CSF. Some patients develop parainfectious autoimmunity following viral CNS infection (usually HSV-1 encephalitis). The significance of detecting herpes nucleic acids in others remains unclear. PMID:27308306
Diagnosis of Plasmodium falciparum infection in man: detection of parasite antigens by ELISA*
Mackey, L. J.; McGregor, I. A.; Paounova, N.; Lambert, P. H.
1982-01-01
An ELISA method has been developed for the diagnosis of Plasmodium falciparum infection in man. Parasites from in vitro cultures of P. falciparum were used as source of antigen for the solid phase and the source of specific antibody was immune Gambian sera; binding of antibody in antigen-coated wells was registered by means of alkaline phosphatase-conjugated anti-human IgG. Parasites were detected on the basis of inhibition of antibody-binding. The test was applied to the detection of parasites in human red blood cells (RBC) from in vitro cultures of P. falciparum and in RBC from infected Gambians; RBC from 100 Geneva blood donors served as normal, uninfected controls. In titration experiments, the degree of antibody-binding inhibition correlated with the number of parasites in the test RBC. Parasites were detected at a level of 8 parasites/106 RBC. Samples of RBC were tested from 126 Gambians with microscopically proven infection; significant antibody-binding inhibition was found in 86% of these cases, where parasitaemia ranged from 10 to 125 000/μl of blood. The presence of high-titre antibody in the test preparations was found to reduce the sensitivity of parasite detection in infected RBC from in vitro cultures mixed with equal volumes of different antibody-containing sera. The sensitivity was restored in most cases by recovering the RBC by centrifugation before testing. In a preliminary experiment, there was no significant difference in antibody-binding inhibition using fresh infected RBC and RBC dried on filter-paper and recovered by elution, although there was greater variation in the latter samples. PMID:7044589
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Liming; Du, Dan; Lu, Donglai
2011-05-05
A sandwich enzyme-linked immunosorbent assay (sELISA) is developed for detection of organophosphorylated butyrylcholinesterase (OP-BChE), a potential biomarker for human exposure to organophosphate insecticides and nerve agents. A pair of antibodies specific to OP-BChE adduct were identified through systematic screening of several anti BChE antibodies (anti-BChE) and anti-phosphoserine antibodies (anti-Pser) from different sources. The selected anti-BChE (set as capture antibody) antibodies recognize both phosphorylated and nonphosphorylated BChE. These antibodies can therefore be used to capture both BChE and OP-BChE from the sample matrices. The anti- Pser (set as detecting antibody) was used to recognize the OP moiety of OP-BChE adducts. Withmore » the combination of the selected antibody pair, several key parameters (such as the concentration of anti-BChE and anti-Pser, and the blocking agent) were optimized to enhance the sensitivity and selectivity of the sELISA. Under the optimal conditions, the sELISA has shown a wide linear range from 0.03 nM to 30 nM, with a detection limit of 0.03 nM. Furthermore, the sELISA was successfully applied to detect OP-BChE using in-vitro biological samples such as rat plasma spiked with OP-BChE with excellent adduct recovery (z>99 %). These results demonstrate that this novel approach holds great promise to develop an ELISA kit and offers a simple and cost-effective tool for screening/evaluating exposure to organophosphate insecticides and nerve agents.« less
Valenti, Ornella; Mikus, Nace; Klausberger, Thomas
2018-05-22
The ability to recognize novel situations is among the most fascinating and vital of the brain functions. A hypothesis posits that encoding of novelty is prompted by failures in expectancy, according to computation matching incoming information with stored events. Thus, unexpected changes in context are detected within the hippocampus and transferred to downstream structures, eliciting the arousal of the dopamine system. Nevertheless, the precise locus of detection is a matter of debate. The dorsal CA1 hippocampus (dCA1) appears as an ideal candidate for operating a mismatch computation and discriminating the occurrence of diverse stimuli within the same environment. In this study, we sought to determine dCA1 neuronal firing during the experience of novel stimuli embedded in familiar contexts. We performed population recordings while head-fixed mice navigated virtual environments. Three stimuli were employed, namely a novel pattern of visual cues, an odor, and a reward with enhanced valence. The encounter of unexpected events elicited profound variations in dCA1 that were assessed both as opposite rate directions and altered network connectivity. When experienced in sequence, novel stimuli elicited specific responses that often exhibited cross-sensitization. Short-latency, event-triggered responses were in accordance with the detection of novelty being computed within dCA1. We postulate that firing variations trigger neuronal disinhibition, and constitute a fundamental mechanism in the processing of unexpected events and in learning. Elucidating the mechanisms underlying detection and computation of novelty might help in understanding hippocampal-dependent cognitive dysfunctions associated with neuropathologies and psychiatric conditions.
Granato, Paul A; DeGilio, Marcia A; Wilson, Elsie M
2016-11-01
The Lyra™ Direct HSV 1+2/VZV Assay is a moderately complex, multiplex PCR assay that qualitatively detects the presence of HSV 1, HSV 2, and VZV DNA in cutaneous and mucocutaneous specimens with a time-to-result of less than 60min. To report a one-year laboratory experience using Lyra assay for testing cutaneous and mucocutaneous specimens for HSV and VZV that resulted in the unexpected detection of VZV in 14 male and female genital specimens. Over a one-year period, 2113 cutaneous and mucocutaneous specimens from male and female patients were submitted for testing using the Lyra assay. An unexpected 14 genital specimens were positive for the presence VZV DNA. Eleven of the 14 specimens were available for confirmatory testing using two alternative molecular methods and Sanger sequencing. Fourteen male and female genital specimens were positive for the presence of VZV DNA. All of the 11 specimens (9 female and 2 male) that were available for confirmatory testing by the alternative molecular method and Sanger sequencing were confirmed as containing VZV DNA. Using of the Lyra assay over a one-year time period, VZV DNA was detected in 126 specimens of which 14 (11.1%) were from male and female genital sites. This rare and unexpected finding suggests that the appearance of zoster lesions in the genital area may not be as uncommon as previously thought and that this finding would have considerable impact on patient counseling and public health considerations. Copyright © 2016 Elsevier B.V. All rights reserved.
Inattentional blindness is influenced by exposure time not motion speed.
Kreitz, Carina; Furley, Philip; Memmert, Daniel
2016-01-01
Inattentional blindness is a striking phenomenon in which a salient object within the visual field goes unnoticed because it is unexpected, and attention is focused elsewhere. Several attributes of the unexpected object, such as size and animacy, have been shown to influence the probability of inattentional blindness. At present it is unclear whether or how the speed of a moving unexpected object influences inattentional blindness. We demonstrated that inattentional blindness rates are considerably lower if the unexpected object moves more slowly, suggesting that it is the mere exposure time of the object rather than a higher saliency potentially induced by higher speed that determines the likelihood of its detection. Alternative explanations could be ruled out: The effect is not based on a pop-out effect arising from different motion speeds in relation to the primary-task stimuli (Experiment 2), nor is it based on a higher saliency of slow-moving unexpected objects (Experiment 3).
Sato, Shinji; Murakami, Akihiro; Kuwajima, Akiko; Takehara, Kazuhiko; Mimori, Tsuneyo; Kawakami, Atsushi; Mishima, Michiaki; Suda, Takafumi; Seishima, Mariko; Fujimoto, Manabu; Kuwana, Masataka
2016-01-01
Objective Autoantibodies to melanoma differentiation-associated gene 5 (MDA5) are specifically expressed in patients with dermatomyositis (DM) and are associated with a subset of DM patients with rapidly progressive interstitial lung disease (RP-ILD). Here, we examined the clinical utility of a newly developed enzyme-linked immunosorbent assay (ELISA) system for detecting these antibodies. Methods Here we developed an improved ELISA for detecting anti-MDA5 antibodies. We then performed a multicenter clinical study involving 8 medical centers and enrolled 242 adult patients with polymyositis (PM)/DM, 190 with non-PM/DM connective tissue disease (CTD), 154 with idiopathic interstitial pneumonia (IIP), and 123 healthy controls. Anti-MDA5 antibodies in the patients’ serum samples were quantified using our newly developed ELISA, and the results were compared to those obtained using the gold-standard immunoprecipitation (IP) assay. In addition, correlations between the ELISA-quantified anti-MDA5 antibodies and clinical characteristics were evaluated. Results In patients with PM/DM, the anti-MDA5 antibody measurements obtained from the ELISA and IP assay were highly concordant; the ELISA exhibited an analytical sensitivity of 98.2%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 99.5% (compared to the IP assay). Anti-MDA5 antibodies were detected in 22.7% of the DM patients, but not in any of the patients with PM, non-PM/DM CTD, or IIP. Clinically amyopathic DM, RP-ILD, arthritis, and fever were more prevalent in DM patients who were anti-MDA5 antibody-positive than in those who were antibody-negative (P ≤ 0.0002 for all comparisons). In addition, anti-MDA5 antibody-positive patients with RP-ILD exhibited higher antibody levels than those without RP-ILD (P = 0.006). Conclusion Our newly developed ELISA can detect anti-MDA5 antibodies as efficiently as the gold standard IP assay and has the potential to facilitate the routine clinical measurement of anti-MDA5 antibodies in patients who suspected to have DM. PMID:27115353
Sato, Shinji; Murakami, Akihiro; Kuwajima, Akiko; Takehara, Kazuhiko; Mimori, Tsuneyo; Kawakami, Atsushi; Mishima, Michiaki; Suda, Takafumi; Seishima, Mariko; Fujimoto, Manabu; Kuwana, Masataka
2016-01-01
Autoantibodies to melanoma differentiation-associated gene 5 (MDA5) are specifically expressed in patients with dermatomyositis (DM) and are associated with a subset of DM patients with rapidly progressive interstitial lung disease (RP-ILD). Here, we examined the clinical utility of a newly developed enzyme-linked immunosorbent assay (ELISA) system for detecting these antibodies. Here we developed an improved ELISA for detecting anti-MDA5 antibodies. We then performed a multicenter clinical study involving 8 medical centers and enrolled 242 adult patients with polymyositis (PM)/DM, 190 with non-PM/DM connective tissue disease (CTD), 154 with idiopathic interstitial pneumonia (IIP), and 123 healthy controls. Anti-MDA5 antibodies in the patients' serum samples were quantified using our newly developed ELISA, and the results were compared to those obtained using the gold-standard immunoprecipitation (IP) assay. In addition, correlations between the ELISA-quantified anti-MDA5 antibodies and clinical characteristics were evaluated. In patients with PM/DM, the anti-MDA5 antibody measurements obtained from the ELISA and IP assay were highly concordant; the ELISA exhibited an analytical sensitivity of 98.2%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 99.5% (compared to the IP assay). Anti-MDA5 antibodies were detected in 22.7% of the DM patients, but not in any of the patients with PM, non-PM/DM CTD, or IIP. Clinically amyopathic DM, RP-ILD, arthritis, and fever were more prevalent in DM patients who were anti-MDA5 antibody-positive than in those who were antibody-negative (P ≤ 0.0002 for all comparisons). In addition, anti-MDA5 antibody-positive patients with RP-ILD exhibited higher antibody levels than those without RP-ILD (P = 0.006). Our newly developed ELISA can detect anti-MDA5 antibodies as efficiently as the gold standard IP assay and has the potential to facilitate the routine clinical measurement of anti-MDA5 antibodies in patients who suspected to have DM.
Horner, Patrick J; Wills, Gillian S; Reynolds, Rosy; Johnson, Anne M; Muir, David A; Winston, Alan; Broadbent, Andrew J; Parker, David; McClure, Myra O
2013-08-01
To investigate what factors influence the detection of Chlamydia trachomatis antibody following genital tract infection. One hundred and sixty-four women with a previous history of C trachomatis infection contributed to an earlier report on the performance of chlamydia antibody ELISA assays. We undertook further analysis to explore how chlamydia antibody assay sensitivity changes with time since infection. Chlamydia antibody was detected in more women soon after the last detection of chlamydia at the lower genital tract than at later times. This holds true for all tests, but the Anilabsystems IgG EIA, Medac pELISA plus ELISA and the Savyon SeroCT-IgG ELISA were less sensitive than the pgp3 ELISA and the Anilabsystems microimmunofluorescence (MIF) assay at all time points except during current infection. Fall in seropositivity in women generally occurred in the early weeks and months following the last episode of chlamydia infection. There was no clear pattern of further reduction in seropositivity after 6 months. Multiple previous episodes were associated with increased seropositivity in the pgp3 assay (two or more vs one, OR 19, p<0.001) and other tests, but the effect was significantly smaller for the Anilabs, Medac and SeroCT MOMP peptide ELISAs, but not for the MIF assay. Chlamydia antibody detection decreases with time since infection and this is most apparent in the first 6 months. In women who have had more than one infection, antibody remained detectable longer for all tests, but this was more marked for the pgp3 ELISA and MIF assay.
Hanazawa, S; Sagiya, T; Kitami, H; Ohta, K; Nishikawa, H; Kitano, S
1991-01-01
The aim of the present study was to develop a monoclonal antibody that recognizes the shared antigen of Porphyromonas endodontalis so that we could use the antibody in direct identification and detection of P. endodontalis in infectious material from apical periodontal patients. We established a hybridoma cell line producing monoclonal antibody (BEB5) specific for P. endodontalis. BEB5 antibody reacted with all of the P. endodontalis strains tested, but not with any of the other black-pigmented Porphyromonas and Bacteroides spp. The antibody reacted specifically with the lipopolysaccharide (LPS) of three P. endodontalis strains of different serotypes (O1K1, O1K2, and O1K-). Western blotting (immunoblotting) analysis confirmed the specificity of the antibody to these LPSs, because the antibody recognized the typical "repetitive ladder" pattern characteristic of LPS on sodium dodecyl sulfate-polyacrylamide electrophoretic gels. These observations demonstrate that P. endodontalis LPS is the shared antigen of this species. The antibody can specifically identify P. endodontalis on nitrocellulose membrane blots of bacterial colonies grown on agar. The antibody is also capable of directly detecting the presence of P. endodontalis in infectious material by immunoslot blot assay. These results indicate that LPS is the shared antigen of P. endodontalis and that BEB5 antibody against LPS is a useful one for direct identification and detection of the organisms in samples from apical periodontal patients. Images PMID:1774262
Hanazawa, S; Sagiya, T; Kitami, H; Ohta, K; Nishikawa, H; Kitano, S
1991-11-01
The aim of the present study was to develop a monoclonal antibody that recognizes the shared antigen of Porphyromonas endodontalis so that we could use the antibody in direct identification and detection of P. endodontalis in infectious material from apical periodontal patients. We established a hybridoma cell line producing monoclonal antibody (BEB5) specific for P. endodontalis. BEB5 antibody reacted with all of the P. endodontalis strains tested, but not with any of the other black-pigmented Porphyromonas and Bacteroides spp. The antibody reacted specifically with the lipopolysaccharide (LPS) of three P. endodontalis strains of different serotypes (O1K1, O1K2, and O1K-). Western blotting (immunoblotting) analysis confirmed the specificity of the antibody to these LPSs, because the antibody recognized the typical "repetitive ladder" pattern characteristic of LPS on sodium dodecyl sulfate-polyacrylamide electrophoretic gels. These observations demonstrate that P. endodontalis LPS is the shared antigen of this species. The antibody can specifically identify P. endodontalis on nitrocellulose membrane blots of bacterial colonies grown on agar. The antibody is also capable of directly detecting the presence of P. endodontalis in infectious material by immunoslot blot assay. These results indicate that LPS is the shared antigen of P. endodontalis and that BEB5 antibody against LPS is a useful one for direct identification and detection of the organisms in samples from apical periodontal patients.
An immuno-biosensor system based on quartz crystal microbalance for avian influenza virus detection
NASA Astrophysics Data System (ADS)
Liu, Shengping; Chen, Guoming; Zhou, Qi; Wei, Yunlong
2007-12-01
For the quick detection of Avian Influenza Virus (AIV), a biosensor based on Quartz Crystal Microbalance (QCM) was fabricated according to the specific bonding principle between antibody and antigen. Staphylococcal Protein A (SPA) was extracted from Staphylococcus and purified. Then SPA was coated on the surface of QCM for immobilizing AIV monoclonal antibodies. The use of AIV monoclonal antibody could enhance the specificity of the immuno-biosensor. A multi-channel piezoelectricity detection system for the immuno-biosensor was developed. The system can work for the quick detection of AIV antigen in the case of the entirely aqueous status owe to one special oscillating circuit designed in this work. The optimum conditions of SPA coating and AIV monoclonal antibody immobilization were investigated utilizing the multi-channel detection system. The preliminary application of the immuno-biosensor system for detection of AIV was evaluated. Results indicate that the immuno-biosensor system can detect the AIV antigens with a linear range of 3-200ng/ml. The system can accomplish the detection of AIV antigens around 40 minutes.
Hatori, Toru; Nakamura, Tamiko; Tsukui, Satoshi
2013-01-01
Serum levels of antibody against Chlamydia trachomatis are used routinely to diagnose chlamydial infection among patients undergoing counseling and testing for sexually transmitted disease at public health centers in Japan, whereas tests for pathogen detection are conducted at most clinics. The objective of the present study was to evaluate the usefulness of a test for detecting C. trachomatis and to compare it with that of screening for serum chlamydia antibodies at a public health center. Serum chlamydia antibody titers were estimated using an ELISA, while C. trachomatis was detected in the urine using the nucleic acid amplification assay that included strand displacement amplification (SDA). We compared the results of 120 patients (64 men and 56 women), because the sensitivity of the method using urine samples from women has been reported to be as high as that using cervical samples. The serum antibody test results were considered to be positive when either one or both of the IgA and IgG antibodies were positive. The overall prevalence of positive results for the antibody test was 24.2% (14.1% for men and 35.7% for women), and that for the SDA method was 7.5% (3.1% for men and 12.5% for women). The concordance rate of the 2 tests was 81.7%, with a kappa statistic of 0.35 (95% CI, 0.10-0.59). Of the 9 subjects who were positive for C. trachomatis using the SDA assay, 1 had serum chlamydia IgA antibodies, 6 had IgG antibodies, 1 had both the antibodies, and 1 had no antibodies. On the other hand, of the 111 subjects who were negative for C. trachomatis, only 8 had chlamydia IgA antibodies, 5 had IgG antibodies, and 8 had both the antibodies. These results indicated there was no association between serum IgA antibodies and the presence of C. trachomatis. The presence of serum chlamydia antibodies was significantly higher in subjects with a past history of genital chlamydial infection than in those without a past history of infection (P<0.01). However, there was no difference in the results of the SDA assay between subjects with or without a previous infection. Thus, although serum chlamydia antibodies are generally measured at public health centers, tests for detecting C. trachomatis should also be used.
Antibody detection tests improve the sensitivity of tuberculosis diagnosis in cattle.
Casal, C; Infantes, J A; Risalde, M A; Díez-Guerrier, A; Domínguez, M; Moreno, I; Romero, B; de Juan, L; Sáez, J L; Juste, R; Gortázar, C; Domínguez, L; Bezos, J
2017-06-01
We evaluated the sensitivity (Se) of the single cervical intradermal tuberculin (SIT) test, two interferon-gamma (IFN-γ) assays and three different antibody detection techniques for bovine tuberculosis (bTB) diagnosis in 131 mixed beef breed cattle. The results of the diagnostic techniques performed over the whole herd, and over the animals confirmed as infected based on the presence of lesions compatible with the disease and/or M. bovis isolation were compared to determine apparent prevalence (AP) and Se. The Se of the SIT test (severe interpretation) was 63.7% (95% CI, 54.54-72.00), while the Se of the IFN-γ assays ranged between 60.2% and 92%. The proportion of infected cattle detected by the different antibody detection techniques ranged from 65.5% to 87.6%. Three of the antibody detection techniques yielded a significant higher (p<0.05) Se than that achieved with the official diagnostic techniques. In addition, the interpretation in parallel of cellular and antibody detection techniques reached the highest Se: 98.2% (95% CI, 93.78-99.51) suggesting that the use of diagnostic techniques detecting both cellular and humoral responses could be considered as an alternative in the control of bTB outbreaks in high prevalence settings. Copyright © 2017 Elsevier Ltd. All rights reserved.
Nong, Rachel Yuan; Wu, Di; Yan, Junhong; Hammond, Maria; Gu, Gucci Jijuan; Kamali-Moghaddam, Masood; Landegren, Ulf; Darmanis, Spyros
2013-06-01
Solid-phase proximity ligation assays share properties with the classical sandwich immunoassays for protein detection. The proteins captured via antibodies on solid supports are, however, detected not by single antibodies with detectable functions, but by pairs of antibodies with attached DNA strands. Upon recognition by these sets of three antibodies, pairs of DNA strands brought in proximity are joined by ligation. The ligated reporter DNA strands are then detected via methods such as real-time PCR or next-generation sequencing (NGS). We describe how to construct assays that can offer improved detection specificity by virtue of recognition by three antibodies, as well as enhanced sensitivity owing to reduced background and amplified detection. Finally, we also illustrate how the assays can be applied for parallel detection of proteins, taking advantage of the oligonucleotide ligation step to avoid background problems that might arise with multiplexing. The protocol for the singleplex solid-phase proximity ligation assay takes ~5 h. The multiplex version of the assay takes 7-8 h depending on whether quantitative PCR (qPCR) or sequencing is used as the readout. The time for the sequencing-based protocol includes the library preparation but not the actual sequencing, as times may vary based on the choice of sequencing platform.
Immunoassay procedures for fiber optic sensors
NASA Astrophysics Data System (ADS)
Ligler, Frances S.
1988-04-01
There is an increasing need for the development of an ultrasensitive immunoassay for use with fiber optic sensors. These detection systems can be used for such applications as disease diagnosis, detection of chemical and biological warfare agents or drugs of abuse, pollution control, therapeutic monitoring, and explosive detection. This specific program is designed to produce generic chemistries for use with existing fiber optic-based sensors to detect pathogens of particular threat to Army personnel as determined by USAMRIID. The detection system under development involves the attachment of antibodies to an optical fiber at high density. In addition, the immobilization must be achieved in a way which retains the antibody's ability to bind antigen. The functionality of the antibody will be tested through the binding of a labelled antigen. In the future, this assay could incorporate the antibodies developed by the Army for pathogens of particularly military concern.
Enzymatic signal amplification for sensitive detection of intracellular antigens by flow cytometry.
Karkmann, U; Radbruch, A; Hölzel, V; Scheffold, A
1999-11-19
Flow cytometry is the method of choice for the analysis of single cells with respect to the expression of specific antigens. Antigens can be detected with specific antibodies either on the cell surface or within the cells, after fixation and permeabilization of the cell membrane. Using conventional fluorochrome-labeled antibodies several thousand antigens are required for clear-cut separation of positive and negative cells. More sensitive reagents, e.g., magnetofluorescent liposomes conjugated to specific antibodies permit the detection of less than 200 molecules per cell but cannot be used for the detection of intracellular antigens. Here, we describe an enzymatic amplification technique (intracellular tyramine-based signal amplification, ITSA) for the sensitive cytometric analysis of intracellular cytokines by immunofluorescence. This approach results in a 10 to 15-fold improvement of the signal-to-noise ratio compared to conventional fluorochrome labeled antibodies and permits the detection of as few as 300-400 intracellular antigens per cell.
Pham, Bach-Nga; Gien, Dominique; Bensaad, Farid; Babinet, Jérome; Dubeaux, Isabelle; Rouger, Philippe; Le Pennec, Pierre-Yves
2012-04-01
Drug-dependent antibodies have been associated with approximately 10% of acquired immune hemolytic anemia cases. These antibodies are a rare cause of interference in pretransfusion red blood cell (RBC) serologic testing. The aim of this work was to report three cases of subjects developing antibodies against co-trimoxazole, a combination of trimethoprim (TMP) and sulfamethoxazole (SMX). Blood samples of donor/patients were referred to our laboratory for the exploration of a positive antibody detection test. There was no recent history of drug taking. Antibody identification was performed by gel test using an indirect antiglobulin test, with reagent RBCs in low-ionic-strength solutions (LISS) containing co-trimoxazole or not. All three sera showed positive reactions when RBCs were resuspended in LISS containing co-trimoxazole, but negative reactions when RBCs were resuspended in LISS without antibiotic. We detected antibodies against co-trimoxazole showing three different antibody patterns: anti-TMP plus anti-SMX, anti-TMP alone, or anti-SMX alone. Anti-TMP showed an apparent anti-Ku specificity in the two cases where it was present. Anti-SMX showed an apparent anti-H specificity in one of the two cases described. The drug-dependent antibodies were not associated with acquired hemolytic anemia or other pathologies. Antibodies against co-trimoxazole may only be detected when using a diluent for reagent RBCs containing the drug in question. Antibody pattern (anti-TMP and/or anti-SMX) may vary according to individuals' immune response. Drug-dependent antibodies may react as antibodies against a high-prevalence antigen, supporting the hypothesis of antibodies to drug and membrane components. Drug-dependent antibodies such as anti-co-trimoxazole may be a serologic finding without clinical features. © 2011 American Association of Blood Banks.
Rapid, whole blood diagnostic test for detecting anti-hantavirus antibody in rats.
Amada, Takako; Yoshimatsu, Kumiko; Yasuda, Shumpei P; Shimizu, Kenta; Koma, Takaaki; Hayashimoto, Nobuhito; Gamage, Chandika D; Nishio, Sanae; Takakura, Akira; Arikawa, Jiro
2013-10-01
Hantavirus is a causative agent of rodent-borne viral zoonoses, hemorrhagic fever with renal syndrome (HFRS) and hantavirus pulmonary syndrome. Seoul virus (SEOV) is a causative agent of urban and laboratory rat-associated HFRS worldwide. Surveillance of rodents has been done mainly by serological detection of hantavirus-specific antibodies by enzyme linked immunosorbent assay (ELISA) and immunofluorescent antibody assay (IFA). An immunochromatographic (ICG) test was developed with the N-terminal 103 amino acids of nucleocapsid protein of Hantaan virus expressed by Escherichia coli as an antigen to detect IgG antibody specific to hantavirus in sera from Rattus sp. animals. Antibody-detecting sensitivity of the ICG test was the same as that of ELISA and about 100-times higher than that of IFA. Overall sensitivities and specificities of the ICG test in comparison to ELISA and IFA for sera from 192 urban rats and 123 laboratory rats were 99.3% and 100%, respectively. Diluted whole blood samples without separation could be used for the ICG test. The ICG test enabled detection of antibodies to SEOV, Hantaan, Dobrava/Belgrade, and Thailand viruses, which are causative agents of HFRS throughout Eurasia. The ICG test is a rapid, simple and safe method for diagnosis of SEOV infection in rats. Copyright © 2013 Elsevier B.V. All rights reserved.
Thibaut, Julien; Mérieux, Yves; Rigal, Dominique; Gillet, Germain
2012-01-01
Background Neonatal alloimmune thrombocytopenia is mostly due to the presence of maternal antibodies against the fetal platelet antigen HPA-1a on the platelet integrin GPIIb-IIIa. Accurate detection of anti-HPA-1a antibodies in the mother is, therefore, critical. Current diagnostic assays rely on the availability of pools of human platelets that vary according to donors and blood centers. There is still no satisfactory standardization of these assays. Design and Methods Peptide aptamer was used to detect and identify HPA-1a-specific antibodies in human serum that do not require human platelets. A peptide aptamer library was screened using an anti-HPA-1a human monoclonal antibody as a bait to isolate an aptamer that mimics the human platelet antigen HPA-1a. Results This is the first report in platelet immunology of the use of a peptide aptamer for diagnostic purposes. This assay gives better results than the MAIPA currently in use, detecting around 90% of the expected alloantibodies. Conclusions This assay could help define a standard for the quantitation of anti-HPA antibodies. This report also demonstrates that peptide aptamers can potentially detect a variety of biomarkers in body fluids; this is of particular interest for diagnostic purposes. PMID:22133781
A microarray immunoassay for simultaneous detection of proteins and bacteria
NASA Technical Reports Server (NTRS)
Delehanty, James B.; Ligler, Frances S.
2002-01-01
We report the development and characterization of an antibody microarray biosensor for the rapid detection of both protein and bacterial analytes under flow conditions. Using a noncontact microarray printer, biotinylated capture antibodies were immobilized at discrete locations on the surface of an avidin-coated glass microscope slide. Preservation of capture antibody function during the deposition process was accomplished with the use of a low-salt buffer containing sucrose and bovine serum albumin. The slide was fitted with a six-channel flow module that conducted analyte-containing solutions over the array of capture antibody microspots. Detection of bound analyte was subsequently achieved using fluorescent tracer antibodies. The pattern of fluorescent complexes was interrogated using a scanning confocal microscope equipped with a 635-nm laser. This microarray system was employed to detect protein and bacterial analytes both individually and in samples containing mixtures of analytes. Assays were completed in 15 min, and detection of cholera toxin, staphylococcal enterotoxin B, ricin, and Bacillus globigii was demonstrated at levels as low as 8 ng/mL, 4 ng/mL, 10 ng/mL, and 6.2 x 10(4) cfu/mL, respectively. The assays presented here are very fast, as compared to previously published methods for measuring antibody-antigen interactions using microarrays (minutes versus hours).
Studentsov, Yevgeniy Y.; Schiffman, Mark; Strickler, Howard D.; Ho, Gloria Y. F.; Pang, Yuk-Ying Susana; Schiller, John; Herrero, Rolando; Burk, Robert D.
2002-01-01
Measurement of antibodies to human papillomavirus (HPV) is complicated by many factors. Although enzyme-linked immunosorbent assays (ELISAs) that use virus-like particles (VLPs) have proved useful, the assays have, in general, had moderate sensitivities and low signal-to-noise ratios. To enhance the performance of the assay, a systematic investigation was undertaken to examine key variables used in ELISAs for the detection of antibodies to VLPs of HPV. Incorporation of two vinyl polymers, polyvinyl alcohol (molecular weight, 50,000) (PVA-50) and polyvinylpyrrolidone (molecular weight, 360,000) (PVP-360), was found to increase the sensitivity as well as the specificity of the assay for the detection of antibodies to VLPs of HPV. In particular, the addition of PVA-50 to the blocking solution reduced the amount of nonspecific binding of antibodies to VLPs and the microplate surface, whereas the addition of PVP-360 increased the sensitivity of antibody detection. The new ELISA demonstrated increased sensitivity and specificity for the detection of cervical HPV type 16 infection compared to those of a prototype assay with coded clinical serum samples from women with known cervicovaginal HPV infection status. It is anticipated that the enhanced ELISA conditions will have wide application to a large number of clinical diagnostic assays. PMID:11980956
Senthilkumaran, Chandrika; Yang, Ming; Bittner, Hilary; Ambagala, Aruna; Lung, Oliver; Zimmerman, Jeffrey; Giménez-Lirola, Luis G; Nfon, Charles
2017-04-01
Virus nucleic acids and antibody response to pathogens can be measured using swine oral fluids (OFs). Detection of foot-and-mouth disease virus (FMDV) genome in swine OFs has previously been demonstrated. Virus isolation and viral antigen detection are additional confirmatory assays for diagnosing FMDV, but these methods have not been evaluated using swine OF. The objectives of this study were to further validate the molecular detection of FMDV in oral fluids, evaluate antigen detection and FMDV isolation from swine OFs, and develop an assay for isotypic anti-FMDV antibody detection in OFs. Ribonucleic acid (RNA) from FMDV was detected in OFs from experimentally infected pigs by quantitative real-time reverse transcription polymerase chain reaction (qRT-PCR) from 1 day post-infection (dpi) to 21 dpi. Foot-and-mouth disease virus (FMDV) was isolated from OFs at 1 to 5 dpi. Additionally, FMDV antigens were detected in OFs from 1 to 6 dpi using a lateral flow immunochromatographic strip test (LFIST), which is a rapid pen-side test, and from 2 to 3 dpi using a double-antibody sandwich enzyme-linked immunosorbent assay (DAS ELISA). Furthermore, FMDV-specific immunoglobulin A (IgA) was detected in OFs using an isotype-specific indirect ELISA starting at dpi 14. These results further demonstrated the potential use of oral fluids for detecting FMDV genome, live virus, and viral antigens, as well as for quantifying mucosal IgA antibody response.
Aebig, J A; Jordan, R L; Lawson, R H; Hsu, H T
1987-01-01
A monoclonal antibody reacting with prunus necrotic ringspot ilarvirus was tested in immunochemical studies, neutralization of infectivity assays, and by immuno-electron microscopy. The antibody was able to detect the 27,000 Mr coat protein of prunus necrotic ringspot ilarvirus in western blots and also detected all polypeptide fragments generated after incubation of whole virus with proteolytic enzymes. In neutralization of infectivity studies, the antibody blocked virus infectivity, although it did not precipitate the antigen in agar gel Ouchterlony double diffusion tests. Immuno-electron microscopy confirmed that the antibody coats virions but does not cause clumping. The antibody may be a useful tool for investigating coat protein-dependent initiation of ilarvirus infection.
Antibody response of sandhill and whooping cranes to an eastern equine encephalitis virus vaccine
Clark, G.G.; Dein, F.J.; Crabbs, C.L.; Carpenter, J.W.; Watts, D.M.
1987-01-01
As a possible strategy to protect whooping cranes (Grus americana) from fatal eastern equine encephalitis (EEE) viral infection, studies were conducted to determine the immune response of this species and sandhill cranes (Grus canadensis) to a formalin-inactivated EEE viral vaccine. Viral-specific neutralizing antibody was elicited in both species after intramuscular (IM) vaccination. Subcutaneous and intravenous routes of vaccination failed to elicit detectable antibody in sandhill cranes. Among the IM vaccinated cranes, the immune response was characterized by nondetectable or low antibody titers that waned rapidly following primary exposure to the vaccine. However, one or more booster doses consistently elicited detectable antibody and/or increased antibody titers in the whooping cranes. In contrast, cranes with pre-existing EEE viral antibody, apparently induced by natural infection, exhibited a rapid increase and sustained high-antibody titers. Even though EEE virus vaccine induced neutralizing antibody and produced no adverse side effects, further studies will be required to determine the protective efficacy of the antibody.
Pharmacokinetic de-risking tools for selection of monoclonal antibody lead candidates
Dostalek, Miroslav; Prueksaritanont, Thomayant; Kelley, Robert F.
2017-01-01
ABSTRACT Pharmacokinetic studies play an important role in all stages of drug discovery and development. Recent advancements in the tools for discovery and optimization of therapeutic proteins have created an abundance of candidates that may fulfill target product profile criteria. Implementing a set of in silico, small scale in vitro and in vivo tools can help to identify a clinical lead molecule with promising properties at the early stages of drug discovery, thus reducing the labor and cost in advancing multiple candidates toward clinical development. In this review, we describe tools that should be considered during drug discovery, and discuss approaches that could be included in the pharmacokinetic screening part of the lead candidate generation process to de-risk unexpected pharmacokinetic behaviors of Fc-based therapeutic proteins, with an emphasis on monoclonal antibodies. PMID:28463063
Handali, Sukwan; Klarman, Molly; Gaspard, Amanda N.; Dong, X. Fan; LaBorde, Ronald; Noh, John; Lee, Yeuk-Mui; Rodriguez, Silvia; Gonzalez, Armando E.; Garcia, Hector H.; Gilman, Robert H.; Tsang, Victor C. W.; Wilkins, Patricia P.
2010-01-01
Taeniasis/cysticercosis caused by Taenia solium is a frequent parasitic infection of the human brain in most of the world. Rapid and simple screening tools to identify taeniasis and cysticercosis cases are needed for control programs, mostly to identify tapeworm carriers which are the source of infection and need to be treated, or as tools for point-of-care case detection or confirmation. These screening assays should be affordable, reliable, rapid, and easy to perform. Immunochromatographic tests meet these criteria. To demonstrate proof of principle, we developed and evaluated two magnetic immunochromatographic tests (MICTs) for detection of human Taenia solium taeniasis antibodies (ES33-MICT) and neurocysticercosis antibodies (T24-MICT). These assays detected stage-specific antibodies by using two recombinant proteins, rES33 for detection of taeniasis antibodies and rT24H for detection of cysticercosis antibodies. The sensitivity and specificity of the ES33-MICT to detect taeniasis infections were 94.5% and 96%, respectively, and those of the T24-MICT to detect cases of human cysticercosis with two or more viable brain cysts were 93.9% and 98.9%, respectively. These data provide proof of principle that the ES33- and T24-MICTs provide rapid and suitable methods to identify individuals with taeniasis and cysticercosis. PMID:20181766
NASA Astrophysics Data System (ADS)
Uda, M. N. A.; Hasfalina, C. M.; Samsuzana, A. A.; Hashim, U.; Ariffin, Shahrul A. B.; Zamri, I.; Nur Sabrina, W.; B. Siti Noraini, B.; Faridah, S.; Mazidah, M.; Gopinath, Subash C. B.
2017-03-01
Rice tungro disease (RTD) causes major losses to rice crop plantation. Hence, a highly sensitive tools need to be developed for the detection of RTD which can be employed in both laboratory and field. An electrochemical immunosensor system for the detection of RTD, based on immobilized specific antibodies conjugated with gold nanoparticle was developed for this purpose. However, this paper focus for RTBV interaction using the conjugated antibodies which is added with polymer and deposited on carbon screen printed working electrodes.
Ertekin, Özlem; Öztürk, Selma; Öztürk, Zafer Ziya
2016-08-11
This study introduces the use of an IgA isotype aflatoxin (AF) specific monoclonal antibody for the development of a highly sensitive Quartz Crystal Microbalance (QCM) immunobiosensor for the detection of AF in inhibitory immunoassay format. The higher molecular weight of IgA antibodies proved an advantage over commonly used IgG antibodies in label free immunobiosensor measurements. IgA and IgG antibodies with similar affinity for AF were used in the comparative studies. Sensor surface was prepared by covalent immobilization of AFB1, using self assembled monolayer (SAM) formed on gold coated Quartz Crystal, with 1-Ethyl-3-(3-dimethylaminopropyl) carbodiimide/N-hydroxy succinimide (EDC/NHS) method using a diamine linker. Nonspecific binding to the surface was decreased by minimizing the duration of EDC/NHS activation. Sensor surface was chemically blocked after AF immobilization without any need for protein blocking. This protein free sensor chip endured harsh solutions with strong ionic detergent at high pH, which is required for the regeneration of the high affinity antibody-antigen interaction. According to the obtained results, the detection range with IgA antibodies was higher than IgG antibodies in QCM immunosensor developed for AFB1.
Kunz, U S; Pospischil, A; Paccaud, M F
1991-06-01
Immunohistological detection of chlamydiae in formalin-fixed and paraffin-embedded sections of various organs from several species is described. In a retrospective study, two antisera, a commercially available monoclonal murine antibody (IgMur) and vitelline immunoglobulins (IgY), extracted from the egg yolk of immunized hens, were compared and tested for their applicability under routine condition. Both antisera were applied to tissues from which chlamydiae had been isolated or in which the presence of chlamydiae had been suspected in specially stained sections. Antigen labelling was optimal with the monoclonal antibody. Vitelline immunoglobulins produced some unspecific reactions, especially in lung tissue sections. Because of the antigenic relationship between the vitelline antibodies and tissues of birds, IgY are not suitable for the detection of psittacosis on avian substrates, when using an indirect immunological method. Staining in other tissues e.g. intestine or placenta was of equal quality as that attained with monoclonal antibodies. Depending on the advantages and disadvantages in every individual case, one of the two antibodies may be chosen for further studies. Vitelline antibodies should be preferred with respect to animal welfare.
Ertekin, Özlem; Öztürk, Selma; Öztürk, Zafer Ziya
2016-01-01
This study introduces the use of an IgA isotype aflatoxin (AF) specific monoclonal antibody for the development of a highly sensitive Quartz Crystal Microbalance (QCM) immunobiosensor for the detection of AF in inhibitory immunoassay format. The higher molecular weight of IgA antibodies proved an advantage over commonly used IgG antibodies in label free immunobiosensor measurements. IgA and IgG antibodies with similar affinity for AF were used in the comparative studies. Sensor surface was prepared by covalent immobilization of AFB1, using self assembled monolayer (SAM) formed on gold coated Quartz Crystal, with 1-Ethyl-3-(3-dimethylaminopropyl) carbodiimide/N-hydroxy succinimide (EDC/NHS) method using a diamine linker. Nonspecific binding to the surface was decreased by minimizing the duration of EDC/NHS activation. Sensor surface was chemically blocked after AF immobilization without any need for protein blocking. This protein free sensor chip endured harsh solutions with strong ionic detergent at high pH, which is required for the regeneration of the high affinity antibody-antigen interaction. According to the obtained results, the detection range with IgA antibodies was higher than IgG antibodies in QCM immunosensor developed for AFB1. PMID:27529243
He, Fang; Kiener, Tanja K; Lim, Xiao Fang; Tan, Yunrui; Raj, Kattur Venkatachalam Ashok; Tang, Manli; Chow, Vincent T K; Chen, Qingfeng; Kwang, Jimmy
2013-01-01
Human Enterovirus 71 (EV71) is a common cause of hand, foot and mouth disease (HFMD) in young children. It is often associated with severe neurological diseases and mortalities in recent outbreaks across the Asia Pacific region. Currently, there is no efficient universal antibody test available to detect EV71 infections. In the present study, an epitope-blocking ELISA was developed to detect specific antibodies to human EV71 viruses in human or animal sera. The assay relies on a novel monoclonal antibody (Mab 1C6) that specifically binds to capsid proteins in whole EV71 viruses without any cross reaction to any EV71 capsid protein expressed alone. The sensitivity and specificity of the epitope-blocking ELISA for EV71 was evaluated and compared to microneutralization using immunized animal sera to multiple virus genotypes of EV71 and coxsackieviruses. Further, 200 serum sample from human individuals who were potentially infected with EV71 viruses were tested in both the blocking ELISA and microneutralization. Results indicated that antibodies to EV71 were readily detected in immunized animals or human sera by the epitope blocking ELISA whereas specimens with antibodies to other enteroviruses yielded negative results. This assay is not only simpler to perform but also shows higher sensitivity and specificity as compared to microneutralization. The epitope-blocking ELISA based on a unique Mab 1C6 provided highly sensitive and 100% specific detection of antibodies to human EV71 viruses in human sera.
Vestergard Jorgensen, P. E.; Olesen, N.J.; Lorenzen, N.; Winton, J.R.; Ristow, S.S.
1991-01-01
Sera collected from cultured rainbow trout Oncorhynchus mykiss surviving outbreaks of infectious hematopoietic necrosis (IHN) or viral hemorrhagic septicemia (VHS) were examined for the presence of antibodies to both of the causative viruses, infectious hematopoietic necrosis virus (IHNV) and Egtved virus (viral hemorrhagic septicemia virus: VHSV). Sera were screened with three serological tests: 50% plaque neutralization test (PNT), immunofluorescence (IF), and enzyme-linked immunosorbent assay (ELISA). In sera from 20 rainbow trout surviving IHN, antibodies to IHNV were detected in 9 fish by PNT, in 12 fish by IF, and in 9 fish by ELISA. In these sera, antibodies cross-reacting with VHSV were rare (detected in 0 fish by PNT, in 1 by IF, and in 1 by ELISA). In sera from 20 rainbow trout surviving VHS, antibodies to VHSV were detected in 9 fish by PNT, in 16 fish by IF, and in 18 fish by ELISA. A considerable percentage of the VHS-survivor sera contained antibodies that cross-reacted with IHNV, as detected by ELISA (16 fish) and 1F (7 fish) but not by PNT (0 fish). The three serological tests appear to be useful tools for IHNV and VHSV epidemiology; however, the presence of cross-reacting antibodies in some sera suggests caution when farms require specific pathogen-free certification for one of the viruses in the presence of the other.
Change blindness and visual memory: visual representations get rich and act poor.
Varakin, D Alexander; Levin, Daniel T
2006-02-01
Change blindness is often taken as evidence that visual representations are impoverished, while successful recognition of specific objects is taken as evidence that they are richly detailed. In the current experiments, participants performed cover tasks that required each object in a display to be attended. Change detection trials were unexpectedly introduced and surprise recognition tests were given for nonchanging displays. For both change detection and recognition, participants had to distinguish objects from the same basic-level category, making it likely that specific visual information had to be used for successful performance. Although recognition was above chance, incidental change detection usually remained at floor. These results help reconcile demonstrations of poor change detection with demonstrations of good memory because they suggest that the capability to store visual information in memory is not reflected by the visual system's tendency to utilize these representations for purposes of detecting unexpected changes.
Early indices of deviance detection in humans and animal models.
Grimm, Sabine; Escera, Carles; Nelken, Israel
2016-04-01
Detecting unexpected stimuli in the environment is a critical function of the auditory system. Responses to unexpected "deviant" sounds are enhanced compared to responses to expected stimuli. At the human scalp, deviance detection is reflected in the mismatch negativity (MMN) and in an enhancement of the middle-latency response (MLR). Single neurons often respond more strongly to a stimulus when rare than when common, a phenomenon termed stimulus-specific adaptation (SSA). Here we compare stimulus-specific adaptation with scalp-recorded deviance-related responses. We conclude that early markers of deviance detection in the time range of the MLR could be a direct correlate of cortical SSA. Both occur at an early level of cortical activation, both are robust findings with low-probability stimuli, and both show properties of genuine deviance detection. Their causal relation with the later scalp-recorded MMN is a key question in this field. Copyright © 2015 Elsevier B.V. All rights reserved.
Epitope mapping of commercial antibodies that detect myocilin.
Patterson-Orazem, Athéna C; Hill, Shannon E; Fautsch, Michael P; Lieberman, Raquel L
2018-05-09
The presence of myocilin is often used in the process of validating trabecular meshwork (TM) cells and eye tissues, but the antibody reagents used for detection are poorly characterized. Indeed, for over a century, researchers have been using antibodies to track proteins of interest in a variety of biological contexts, but many antibodies remain ill-defined at the molecular level and in their target epitope. Such issues have prompted efforts from major funding agencies to validate reagents and combat reproducibility issues across biomedical sciences. Here we characterize the epitopes recognized by four commercial myocilin antibodies, aided by structurally and biochemically characterized myocilin fragments. All four antibodies recognize enriched myocilin secreted from human TM cell media. The detection of myocilin fragments by ELISA and Western blot reveal a variety of epitopes across the myocilin polypeptide chain. A more precise understanding of myocilin antibody targets, including conformational specificity, should aid the community in standardizing protocols across laboratories and in turn, lead to a better understanding of eye physiology and disease. Copyright © 2018 Elsevier Ltd. All rights reserved.
Adlhoch, Cornelia; Kaiser, Marco; Hoehne, Marina; Mas Marques, Andreas; Stefas, Ilias; Veas, Francisco; Ellerbrok, Heinz
2011-02-10
The principle of a capture ELISA is binding of specific capture antibodies (polyclonal or monoclonal) to the surface of a suitable 96 well plate. These immobilized antibodies are capable of specifically binding a virus present in a clinical sample. Subsequently, the captured virus is detected using a specific detection antibody. The drawback of this method is that a capture ELISA can only function for a single virus captured by the primary antibody. Human Apolipoprotein H (ApoH) or β2-glycoprotein 1 is able to poly-specifically bind viral pathogens. Replacing specific capture antibodies by ApoH should allow poly-specific capture of different viruses that subsequently could be revealed using specific detection antibodies. Thus, using a single capture ELISA format different viruses could be analysed depending on the detection antibody that is applied. In order to demonstrate that this is a valid approach we show detection of group A rotaviruses from stool samples as a proof of principle for a new method of capture ELISA that should also be applicable to other viruses. Stool samples of different circulating common human and potentially zoonotic group A rotavirus strains, which were pretested in commercial EIAs and genotyped by PCR, were tested in parallel in an ApoH-ELISA set-up and by quantitative real-time PCR (qPCR). Several control samples were included in the analysis. The ApoH-ELISA was suitable for the capture of rotavirus-particles and the detection down to 1,000 infectious units (TCID(50/ml)). Subsets of diagnostic samples of different G- and P-types were tested positive in the ApoH-ELISA in different dilutions. Compared to the qPCR results, the analysis showed high sensitivity, specificity and low cross-reactivity for the ApoH-ELISA, which was confirmed in receiver operating characteristics (ROC) analysis. In this study the development of a highly sensitive and specific capture ELISA was demonstrated by combining a poly-specific ApoH capture step with specific detection antibodies using group A rotaviruses as an example.
Dutta, S K; Rice, R M; Hughes, T D; Savage, P K; Myrup, A C
1987-01-01
An indirect enzyme-linked immunosorbent assay (ELISA) was developed which was specific and sensitive in detecting antibodies to Ehrlichia risticii in Potomac horse fever (PHF). The ELISA antibody titers were correlated with the indirect fluorescent antibody (IFA) titers. E. risticii propagated in human histiocyte culture was purified on renografin gradient and the band of the organisms at a density of 1.182 g/ml was used as antigen. ELISA antibody titers were determined through computer assisted analysis, the observed antibody titers were derived by serial serum dilutions and using a resultant standard curve the predicted antibody titers were obtained from a single serum dilution. The standard curve had a correlation coefficient of 0.8975. The observed and predicted antibody titers were in good agreement, as the respective titers fell within a two-fold range. There was a good correlation between ELISA and IFA test results, but the ELISA titers were several times higher. In experimental infections of horses produced with the infected equine whole blood and the Ehrlichia infected macrophage culture, the antibodies were first detected in two weeks and one week postinoculation (PI), respectively. In both cases the titers reached a peak in about 4 weeks PI with a mean titer of 1:16558 and 1:4030, respectively. The antibody titers of the convalescent sera of field cases of PHF were comparatively lower than the experimentally infected horses.
Zhao, Xuemei; Bender, Florent; Shukla, Rajiv; Kang, John J; Caro-Aguilar, Ivette; Laterza, Omar F
2016-04-01
Pathogenic Clostridium difficile produces two proinflammatory exotoxins, toxin A and toxin B. Low level of serum antitoxin IgG antibodies is a risk factor for the development of primary and recurrent C. difficile infection (CDI). We developed and validated two sensitive, titer-based electrochemiluminescence assays for the detection of serum antibody levels against C. difficile toxins A and B. These assays demonstrated excellent precision. The sensitivity of the assays allowed the detection of antitoxin A and antitoxin B IgG antibodies in all tested serum samples during assay validation. The validated titer-based assays enable assessment of antitoxin A and antitoxin B IgG antibodies as potential biomarkers to identify patients with CDI at increased risk for CDI recurrence.
Wang, Zanyu; Jiyuan, Yin; Su, Chen; Xinyuan, Qiao
2015-01-01
Abstract Porcine epidemic diarrhea virus (PEDV), a coronavirus, can cause acute diarrhea and dehydration in pigs. In the current study, two positive monoclonal cell lines (5D7 and 3H4) specific for PEDV were established, and the immunoreactivity of the monoclonal antibodies was confirmed by immunofluorescence and dot-immunobinding assays. A method, termed antigen capture enzyme-linked immunosorbent assay (AC-ELISA), which used the monoclonal antibody 5D7 as the detecting antibody and rabbit antiserum of PEDV protein S as the capture antibody, was developed. Compared with the reverse transcription polymerase chain reaction method of detecting PEDV in fecal samples, AC-ELISA showed similar sensitivity and specificity. These results suggested that AC-ELISA would be useful for the diagnosis and epidemiological studies of PEDV. PMID:25658793
Gupta, Shalini; Indelicato, Stephen R; Jethwa, Vijay; Kawabata, Thomas; Kelley, Marian; Mire-Sluis, Anthony R; Richards, Susan M; Rup, Bonita; Shores, Elizabeth; Swanson, Steven J; Wakshull, Eric
2007-04-10
The administration of biological therapeutics can evoke some level of immune response to the drug product in the receiving subjects. An immune response comprised of neutralizing antibodies can lead to loss of efficacy or potentially more serious clinical sequelae. Therefore, it is important to monitor the immunogenicity of biological therapeutics throughout the drug product development cycle. Immunoassays are typically used to screen for the presence and development of anti-drug product antibodies. However, in-vitro cell-based assays prove extremely useful for the characterization of immunoassay-positive samples to determine if the detected antibodies have neutralizing properties. This document provides scientific recommendations based on the experience of the authors for the development of cell-based assays for the detection of neutralizing antibodies in non-clinical and clinical studies.
Panda, Rakhi; Zoerb, Hans F; Cho, Chung Y; Jackson, Lauren S; Garber, Eric A E
2015-06-01
In 2013 the U.S. Food and Drug Administration (FDA) defined the term ''gluten-free'' and identified a gap in the analytical methodology for detection and quantification of gluten in foods subjected to fermentation and hydrolysis. To ascertain the ability of current enzyme-linked immunosorbent assays (ELISAs) to detect and quantify gluten in fermented and hydrolyzed products, sorghum beer was spiked in the initial phases of production with 0, 20, and 200 μg/ml wheat gluten, and samples were collected throughout the beer production process. The samples were analyzed using five sandwich ELISAs and two competitive ELISAs and by sodium dodecyl sulfate-polyacrylamide gel electrophoresis with Western analysis employing four antibodies (MIoBS, R5, G12, and Skerritt). The sensitivity of the MIoBS ELISA (0.25 ppm) enabled the reliable detection of gluten throughout the manufacturing process, including fermentation, when the initial concentration of 20 μg/ml dropped to 2 μg/ml. The R5 antibody-based and G12 antibody-based sandwich ELISAs were unable to reliably detect gluten, initially at 20 μg/ml, after the onset of production. The Skerritt antibody-based sandwich ELISA overestimated the gluten concentration in all samples. The R5 antibody-based and G12 antibody-based competitive ELISAs were less sensitive than the sandwich ELISAs and did not provide accurate results for quantifying gluten concentration. The Western analyses were able to detect gluten at less than 5 μg/ml in the samples and confirmed the results of the ELISAs. Although further research is necessary before all problems associated with detection and quantification of hydrolyzed and fermented gluten are resolved, the analytical methods recommended by the FDA for regulatory samples can detect ≥ 20 μg/ml gluten that has undergone brewing and fermentation processes associated with the manufacture of beer.
Ebai, Tonge; Souza de Oliveira, Felipe Marques; Löf, Liza; Wik, Lotta; Schweiger, Caroline; Larsson, Anders; Keilholtz, Ulrich; Haybaeck, Johannes; Landegren, Ulf; Kamali-Moghaddam, Masood
2017-09-01
Detecting proteins at low concentrations in plasma is crucial for early diagnosis. Current techniques in clinical routine, such as sandwich ELISA, provide sensitive protein detection because of a dependence on target recognition by pairs of antibodies, but detection of still lower protein concentrations is often called for. Proximity ligation assay with rolling circle amplification (PLARCA) is a modified proximity ligation assay (PLA) for analytically specific and sensitive protein detection via binding of target proteins by 3 antibodies, and signal amplification via rolling circle amplification (RCA) in microtiter wells, easily adapted to instrumentation in use in hospitals. Proteins captured by immobilized antibodies were detected using a pair of oligonucleotide-conjugated antibodies. Upon target recognition these PLA probes guided oligonucleotide ligation, followed by amplification via RCA of circular DNA strands that formed in the reaction. The RCA products were detected by horseradish peroxidase-labeled oligonucleotides to generate colorimetric reaction products with readout in an absorbance microplate reader. We compared detection of interleukin (IL)-4, IL-6, IL-8, p53, and growth differentiation factor 15 (GDF-15) by PLARCA and conventional sandwich ELISA or immuno-RCA. PLARCA detected lower concentrations of proteins and exhibited a broader dynamic range compared to ELISA and iRCA using the same antibodies. IL-4 and IL-6 were detected in clinical samples at femtomolar concentrations, considerably lower than for ELISA. PLARCA offers detection of lower protein levels and increased dynamic ranges compared to ELISA. The PLARCA procedure may be adapted to routine instrumentation available in hospitals and research laboratories. © 2017 American Association for Clinical Chemistry.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gust, I.D.; Feinstone, S.M.; Purcell, R.H.
1980-01-01
A sensitive ''Farr'' assay, utilizing /sup 125/I-labelled DNA was developed for detecting antibody to single-stranded DNA (anti-ssDNA). The test was shown to be specific and as sensitive as assays using /sup 14/C-labelled DNA, for the detection of antibody in patients with connective tissue diseases. Groups of sera from patients with naturally acquired viral hepatitis and experimentally infected chimpanzees were tested for anti-ssDNA by the /sup 125/I assay and by counterimmunoelectrophoresis (CIEP). No consistent pattern was observed with either technique, indicating the elevated levels of this antibody are not as reliable markers of parenchymal liver damage as had been previously suggested.
Sealy, Robert E; Surman, Sherri L; Hurwitz, Julia L
2017-05-09
The RSV vaccine field suffered a major set-back when children were vaccinated with a formalin-inactivated RSV vaccine (FI-RSV). Unexpectedly, the vaccinated children fared worse than unvaccinated children when they were naturally infected with RSV. Mouse models were then developed that implicated the CD4 + T helper cell population as a contributor to adverse events. Today, the T cell is viewed with much caution in the RSV field, and its induction by vaccination is sometimes discouraged. Here we re-emphasize the beneficial role of the CD4 + T cell. Experiments were performed with RSV-infected nude mice that received CD4 + T cells by adoptive transfer. Data demonstrated that CD4 + T cells were necessary for the induction of mucosal and systemic RSV-specific antibodies, for the establishment of RSV-specific IgG and IgA antibody secreting cells in the upper and lower respiratory tract, and for RSV clearance. Copyright © 2017 Elsevier Ltd. All rights reserved.
π-Clamp-mediated cysteine conjugation
NASA Astrophysics Data System (ADS)
Zhang, Chi; Welborn, Matthew; Zhu, Tianyu; Yang, Nicole J.; Santos, Michael S.; van Voorhis, Troy; Pentelute, Bradley L.
2016-02-01
Site-selective functionalization of complex molecules is one of the most significant challenges in chemistry. Typically, protecting groups or catalysts must be used to enable the selective modification of one site among many that are similarly reactive, and general strategies that selectively tune the local chemical environment around a target site are rare. Here, we show a four-amino-acid sequence (Phe-Cys-Pro-Phe), which we call the ‘π-clamp’, that tunes the reactivity of its cysteine thiol for site-selective conjugation with perfluoroaromatic reagents. We use the π-clamp to selectively modify one cysteine site in proteins containing multiple endogenous cysteine residues. These examples include antibodies and cysteine-based enzymes that would be difficult to modify selectively using standard cysteine-based methods. Antibodies modified using the π-clamp retained binding affinity to their targets, enabling the synthesis of site-specific antibody-drug conjugates for selective killing of HER2-positive breast cancer cells. The π-clamp is an unexpected approach to mediate site-selective chemistry and provides new avenues to modify biomolecules for research and therapeutics.
Wright, Terry W.; Malone, Jane E.; Haidaris, Constantine G.; Harber, Martha; Sant, Andrea J.; Nayak, Jennifer L.
2016-01-01
ABSTRACT Pneumocystis pneumonia (PcP) is a life-threatening infection that affects immunocompromised individuals. Nearly half of all PcP cases occur in those prescribed effective chemoprophylaxis, suggesting that additional preventive methods are needed. To this end, we have identified a unique mouse Pneumocystis surface protein, designated Pneumocystis cross-reactive antigen 1 (Pca1), as a potential vaccine candidate. Mice were immunized with a recombinant fusion protein containing Pca1. Subsequently, CD4+ T cells were depleted, and the mice were exposed to Pneumocystis murina. Pca1 immunization completely protected nearly all mice, similar to immunization with whole Pneumocystis organisms. In contrast, all immunized negative-control mice developed PcP. Unexpectedly, Pca1 immunization generated cross-reactive antibody that recognized Pneumocystis jirovecii and Pneumocystis carinii. Potential orthologs of Pca1 have been identified in P. jirovecii. Such cross-reactivity is rare, and our findings suggest that Pca1 is a conserved antigen and potential vaccine target. The evaluation of Pca1-elicited antibodies in the prevention of PcP in humans deserves further investigation. PMID:28031260
Tournefier, A
1975-01-01
Humoral immunoglobulin synthesis has been studied in two adult urodeles, Pleurodeles waltlii Michah. and Triturus alpestris Laur. following SRBC immunization. The specific antibody response is detected after a long period of immunization and is due exclusively to 'incomplete' antibodies which are unable to induce agglutination. The antibody titre is essentially dependent on the number of stimulations rather than on the dose or nature of the antigen (papainized or normal erythrocytes). Antibodies are detected in only 50 per cent of the immunized animals, 50 per cent never respond. This suggests that the latter group does not possess the genetic equipment (Ir genes) to recognize the antigenic determinants and to synthesize the corresponding antibodies. The sedimentation coefficient of the synthesized immunoglobulins was investigated by sucrose density gradient centrifugation and their characterization was carried out by starch and polyacrylamide gel electrophoresis. With this peculiar antigen even after a booster injection, only one class of immunoglobulin, an 18-2S IgM could be detected. PMID:49296
Martínez, M I; Rodríguez, J M; Suárez, A; Martínez, J M; Azcona, J I; Hernández, P E
1997-06-01
Six mice were immunized intraperitoneally (i.p.) with a chemically synthesized 9-mer fragment (PH1) designed from the N-terminal part of the bacteriocin pediocin PA-1 and conjugated to keyhole limpet haemocyanin (KLH). After three doses of the immunogen had been administered, serum-specific antibodies were detected by a competitive direct ELISA. Myeloma cells were injected i.p. into mice in order to obtain ascites polyclonal antibodies. Although four mice developed ascites, only mouse 2 had detectable specific antibodies in the ascites fluid. The serum and ascites antibodies were specific for PH1 but they did not recognize the whole pediocin PA-1 molecule. This is the first attempt to generate antibodies against bacteriocins with a chemically synthesized oligopeptide as immunogen. This approach still remains attractive for detection, quantification, mode of action studies and purification of bacteriocins, especially those for which the purification process is difficult or inefficient at present.
NASA Astrophysics Data System (ADS)
Hun, Xu; Zhang, Zhujun
2009-10-01
Fluorescent nanoparticles (FNs) with unique optical properties may be useful as biosensors in living cancer cell imaging and cancer targeting. In this study, anti-EGFR antibody conjugated fluorescent nanoparticles (FNs) (anti-EGFR antibody conjugated FNs) probe was used to detect breast cancer cells. FNs with excellent character such as non-toxicity and photostability were first synthesized with a simple, cost-effective and environmentally friendly modified Stőber synthesis method, and then successfully modified with anti-EGFR antibody. This kind of fluorescence probe based on the anti-EGFR antibody conjugated FNs has been used to detect breast cancer cells with fluorescence microscopy imaging technology. The experimental results demonstrate that the anti-EGFR antibody conjugated FNs can effectively recognize breast cancer cells and exhibited good sensitivity and exceptional photostability, which would provide a novel way for the diagnosis and curative effect observation of breast cancer cells and offer a new method in detecting EGFR.
Dixon, Eric P; King, Lorraine M; Nelson, Ramona; Simkins, Stephen G; Knapp, Steven L; Brough, George H; Lenz, Karen L; Henderson, Dorian T; Whitehead, Clark M; Hessling, Janice; Brown, Charlotte A; Malinowski, Douglas P
2017-03-01
The Papanicolaou (Pap) screen has been successful in reducing cervical cancer; but exhibits low sensitivity when detecting cervical dysplasia. Use of molecular biomarkers in Pap tests may improve diagnostic accuracy. Monoclonal antibodies to Minichromosome Maintenance Protein 2 (MCM2) and DNA Topoisomerase II α (TOP2A) were selected for use in IHC based on their ability to differentiate normal from diseased cervical tissues in tissue microarrays. Enhanced Green Fluorescent Protein Western blot analysis was used to help identify binding epitopes specific to MCM2 and TOP2A antibody clones. Antibody affinity was determined by solution phase affinity measurement and immunohistochemistry was performed using high affinity MCM2 or TOP2A antibodies on serial histological sections. Antibody clones to MCM2 and TOP2A clones were selected based on their ability to detect over expression in abnormal cervical epithelia. In IHC, MCM2-27C5.6 and MCM2-26H6.19 demonstrated superior staining in abnormal cervical tissue over the MCM2-CRCT2.1 antibody. A combination of MCM2 and TOP2A antibodies showed greater staining when compared to staining with any of the antibodies alone on serial histological sections. Distinct linear epitopes were elucidated for each of the MCM2 and TOP2A clones. Affinity values (Kd) for MCM2 or TOP2A antibodies had a similar range. In a research study, the MCM2 and TOP2A (BD ProEx™ C) antibody cocktail showed increased epithelia staining with increasing dysplasia. The use of BD ProEx™ C in combination with H&E staining enhanced immunohistochemical discrimination of dysplastic and non-dysplastic FFPE cervical tissue specimens. BD ProEx™ C containing MCM2 and TOP2A antibodies showed strong specific nuclear staining that correlated with increased dysplasia and lesion severity. Enhanced performance of the antibodies was linked to their unique topography recognition. BD ProEx™ C incorporates antibodies that enhance detection of CIN2+ cervical disease. Copyright © 2017 Elsevier B.V. All rights reserved.
Yu, Yanbin; Piddington, Christopher; Fitzpatrick, Dan; Twomey, Brian; Xu, Ren; Swanson, Steven J; Jing, Shuqian
2006-10-20
The presence of neutralizing antibodies against protein therapeutics is a concern in the biomedical field. Such antibodies not only reduce the efficacy of protein therapeutics, but also impose potential dangers to the patients receiving them. To date, a small number of in vitro cell-based bioassays for detecting neutralizing antibodies against therapeutic proteins have been developed. Most of the existing assays, however, either involve the use of radioactive materials or have limited sensitivities and/or poor specificities. With advances in mRNA profiling and detection techniques, we have established a novel and non-radioactive bioassay system using branched DNA (bDNA) technology for detecting protein-therapeutic neutralizing antibodies in patient serum. Our assay measures the variations of target gene expression that reflect the biologic effect of the therapeutic agent and the capability of the antibodies, if present, to neutralize the therapeutics. Compared with most existing assays, the new assay is more sensitive and specific, and completely eliminates the use of radioactive materials. Application of the new assay system can be widely expanded if new target genes and responding cell lines for other therapeutics are identified or engineered.
Increasing the sensitivity of reverse phase protein arrays by antibody-mediated signal amplification
2010-01-01
Background Reverse phase protein arrays (RPPA) emerged as a useful experimental platform to analyze biological samples in a high-throughput format. Different signal detection methods have been described to generate a quantitative readout on RPPA including the use of fluorescently labeled antibodies. Increasing the sensitivity of RPPA approaches is important since many signaling proteins or posttranslational modifications are present at a low level. Results A new antibody-mediated signal amplification (AMSA) strategy relying on sequential incubation steps with fluorescently-labeled secondary antibodies reactive against each other is introduced here. The signal quantification is performed in the near-infrared range. The RPPA-based analysis of 14 endogenous proteins in seven different cell lines demonstrated a strong correlation (r = 0.89) between AMSA and standard NIR detection. Probing serial dilutions of human cancer cell lines with different primary antibodies demonstrated that the new amplification approach improved the limit of detection especially for low abundant target proteins. Conclusions Antibody-mediated signal amplification is a convenient and cost-effective approach for the robust and specific quantification of low abundant proteins on RPPAs. Contrasting other amplification approaches it allows target protein detection over a large linear range. PMID:20569466
ERIC Educational Resources Information Center
Heal, Nicole A.; Hanley, Gregory P.
2011-01-01
This study describes an unexpected behavioral process that influenced behavior during the teaching of concepts to a 4-year-old girl. The efficacy of and preference for three strategies that varied in teacher directedness were assessed in a multielement design and concurrent-chains arrangement, respectively. The strategy that involved the most…
Näsholm, Erika; Rohlfing, Sarah; Sauer, James D.
2014-01-01
Closed Circuit Television (CCTV) operators are responsible for maintaining security in various applied settings. However, research has largely ignored human factors that may contribute to CCTV operator error. One important source of error is inattentional blindness – the failure to detect unexpected but clearly visible stimuli when attending to a scene. We compared inattentional blindness rates for experienced (84 infantry personnel) and naïve (87 civilians) operators in a CCTV monitoring task. The task-relevance of the unexpected stimulus and the length of the monitoring period were manipulated between participants. Inattentional blindness rates were measured using typical post-event questionnaires, and participants' real-time descriptions of the monitored event. Based on the post-event measure, 66% of the participants failed to detect salient, ongoing stimuli appearing in the spatial field of their attentional focus. The unexpected task-irrelevant stimulus was significantly more likely to go undetected (79%) than the unexpected task-relevant stimulus (55%). Prior task experience did not inoculate operators against inattentional blindness effects. Participants' real-time descriptions revealed similar patterns, ruling out inattentional amnesia accounts. PMID:24465932
Mishima, Eikan; Jinno, Daisuke; Akiyama, Yasutoshi; Itoh, Kunihiko; Nankumo, Shinnosuke; Shima, Hisato; Kikuchi, Koichi; Takeuchi, Yoichi; Elkordy, Alaa; Suzuki, Takehiro; Niizuma, Kuniyasu; Ito, Sadayoshi; Tomioka, Yoshihisa; Abe, Takaaki
2015-01-01
The biological roles of RNA modifications are still largely not understood. Thus, developing a method for detecting RNA modifications is important for further clarification. We developed a method for detecting RNA modifications called immuno-northern blotting (INB) analysis and herein introduce its various capabilities. This method involves the separation of RNAs using either polyacrylamide or agarose gel electrophoresis, followed by transfer onto a nylon membrane and subsequent immunoblotting using antibodies against modified nucleosides for the detection of specific modifications. We confirmed that INB with the antibodies for 1-methyladenosine (m1A), N6-methyladenosine (m6A), pseudouridine, and 5-methylcytidine (m5C) showed different modifications in a variety of RNAs from various species and organelles. INB with the anti-m5C antibody revealed that the antibody cross-reacted with another modification on DNA, suggesting the application of this method for characterization of the antibody for modified nucleosides. Additionally, using INB with the antibody for m1A, which is a highly specific modification in eukaryotic tRNA, we detected tRNA-derived fragments known as tiRNAs under the cellular stress response, suggesting the application for tracking target RNA containing specific modifications. INB with the anti-m6A antibody confirmed the demethylation of m6A by the specific demethylases fat mass and obesity-associated protein (FTO) and ALKBH5, suggesting its application for quantifying target modifications in separated RNAs. Furthermore, INB demonstrated that the knockdown of FTO and ALKBH5 increased the m6A modification in small RNAs as well as in mRNA. The INB method has high specificity, sensitivity, and quantitative capability, and it can be employed with conventional experimental apparatus. Therefore, this method would be useful for research on RNA modifications and metabolism.
Quantitative blood group typing using surface plasmon resonance.
Then, Whui Lyn; Aguilar, Marie-Isabel; Garnier, Gil
2015-11-15
The accurate and reliable typing of blood groups is essential prior to blood transfusion. While current blood typing methods are well established, results are subjective and heavily reliant on analysis by trained personnel. Techniques for quantifying blood group antibody-antigen interactions are also very limited. Many biosensing systems rely on surface plasmon resonance (SPR) detection to quantify biomolecular interactions. While SPR has been widely used for characterizing antibody-antigen interactions, measuring antibody interactions with whole cells is significantly less common. Previous studies utilized SPR for blood group antigen detection, however, showed poor regeneration causing loss of functionality after a single use. In this study, a fully regenerable, multi-functional platform for quantitative blood group typing via SPR detection is achieved by immobilizing anti-human IgG antibody to the sensor surface, which binds to the Fc region of human IgG antibodies. The surface becomes an interchangeable platform capable of quantifying the blood group interactions between red blood cells (RBCs) and IgG antibodies. As with indirect antiglobulin tests (IAT), which use IgG antibodies for detection, IgG antibodies are initially incubated with RBCs. This facilitates binding to the immobilized monolayer and allows for quantitative blood group detection. Using the D-antigen as an example, a clear distinction between positive (>500 RU) and negative (<100 RU) RBCs is achieved using anti-D IgG. Complete regeneration of the anti-human IgG surface is also successful, showing negligible degradation of the surface after more than 100 regenerations. This novel approach is validated with human-sourced whole blood samples to demonstrate an interesting alternative for quantitative blood grouping using SPR analysis. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.
Przewodowska, Agnieszka
2017-01-01
The quarantine bacterium Clavibacter michiganensis subsp. sepedonicus (Cms) causes bacterial ring rot (BRR) in potato but is difficult to detect, hampering the diagnosis of this disease. ELISA immunoassays have not been widely used to detect Cms because commercially available anti-Cms antibodies detect mainly EPS-producing bacteria and can fail to detect strains that do not produce EPS. In the current study, we developed a new type of polyclonal antibody that specifically detects Clavibacter michiganensis subsp. sepedonicus bacteria irrespective of their EPS level. We first found that the presence of bacterial EPS precluded quantitative measurement of bacteria by currently available immunoenzymatic methods, but that washing Cms cells with acidic and basic buffers to remove EPS before analysis successfully standardized ELISA results. We used a mix of three strains of Cms with diverse EPS levels to generate antigen for production of antibodies recognizing Cms cells with and without an EPS layer (IgG-EPS and IgG-N-EPS, respectively). The resulting IgG-N-EPS recognized almost all Cms strains tested in this work regardless of their mucoidal level. The availability of this new antibody renders immunological diagnostics of Cms more sensitive and reliable, as our newly developed antibodies can be used in many type of immunoassays. This work represents an important step forward in efforts to diagnose and prevent the spread of BRR, and the methods and solutions developed in this work are covered by six Polish, one European and one US patents. PMID:28068400
Lo, Kai-Yin; Sun, Yung-Shin; Landry, James P.; Zhu, Xiangdong; Deng, Wenbin
2012-01-01
Conventional fluorescent microscopy is routinely used to detect cell surface markers through fluorophore-conjugated antibodies. However, fluorophore-conjugation of antibodies alters binding properties such as strength and specificity of the antibody in ways often uncharacterized. The binding between antibody and antigen might not be in the native situation after such conjugation. Here, we present an oblique-incidence reflectivity difference (OI-RD) microscope as an effective method for label-free, real-time detection of cell surface markers and apply such a technique to analysis of Stage-Specific Embryonic Antigen 1 (SSEA1) on stem cells. Mouse stem cells express SSEA1 on their surfaces and the level of SSEA1 decreases when the cells start to differentiate. In this study, we immobilized mouse stem cells and non-stem cells (control) on a glass surface as a microarray and reacted the cell microarray with unlabeled SSEA1 antibodies. By monitoring the reaction with an OI-RD microscope in real time, we confirmed that the SSEA1 antibodies only bind to the surface of the stem cells while not to the surface of non-stem cells. From the binding curves, we determined the equilibrium dissociation constant (Kd) of the antibody with the SSEA1 markers on the stem cell surface. The results concluded that OI-RD microscope can be used to detect binding affinities between cell surface markers and unlabeled antibodies bound to the cells. The information could be another indicator to determine the cell stages. PMID:21781038
Gleeson, Michael; Bishop, Nicolette C; Struszczak, Lauren
2016-08-01
To assess evidence of health and immune benefit by consumption of a Lactobacillus casei Shirota probiotic in highly physically active people. Single-centre, population-based, randomized, double-blind, placebo-controlled trial. Daily ingestion of probiotic (PRO) or placebo (PLA) for 20 weeks for n = 243 (126 PRO, 117 PLA) university athletes and games players. Subjects completed validated questionnaires on upper respiratory tract infection symptoms (URS) on a daily basis and on physical activity status at weekly intervals during the intervention period. Blood samples were collected before and after 20 weeks of the intervention for determination of Epstein Barr virus (EBV) and cytomegalovirus (CMV) serostatus and antibody levels. URS episode incidence was unexpectedly low (mean 0.6 per individual) and was not significantly different on PRO compared with PLA. URS episode duration and severity were also not influenced by PRO. A significant time × group interaction effect was observed for plasma CMV antibody titres in CMV seropositive participants (p < 0.01) with antibody titre falling in the PRO group but remaining unchanged in the PLA group over time. A similar effect was found for plasma EBV antibody titres in EBV seropositive participants (p < 0.01) with antibody titre falling in the PRO group but increasing in the PLA group over time. In summary, regular ingestion of PRO did not reduce URS episode incidence which might be attributable to the low URS incidence in this study. Regular ingestion of PRO reduced plasma CMV and EBV antibody titres, an effect that can be interpreted as a benefit to overall immune status.
Long-term in vitro reactivity for HLA antibodies and comparison of detection using serum vs. plasma
Norris, Philip J.; Lee, Jar-How; Carrick, Danielle M.; Gottschall, Jerome L.; Lebedeva, Mila; de Castro, B.R.; Kleinman, Steven H.; Busch, Michael P.
2010-01-01
BACKGROUND HLA antibodies are a possible cause of transfusion-related acute lung injury (TRALI), and fluorescent bead assays are often used for antibody detection. Serum is the manufacturer’s recommended sample, but plasma may be easier to obtain for studies of HLA antibody prevalence and TRALI case investigations. STUDY DESIGN AND METHODS Specimens were obtained from 44 multiparous females positive for HLA antibodies by lymphocytotoxicity testing at least 13 years prior, and from 1,000 contemporary blood donors. Screening tests were performed using a Luminex-based assay. In addition to comparing results obtained with paired plasma and serum samples, the effects of storage at 4 °C for one week and of multiple freeze-thaw cycles were evaluated. RESULTS Of 42 evaluable subjects with HLA antibodies documented >13 years earlier, only 1 showed loss of detectable antibodies, with 39 (93%) positive in the screening assay for class I and 24 (57%) positive in the screening assay for HLA class II antibodies. In 968 evaluable contemporary donors, 291 screened positive for HLA class I and 206 for HLA class II antibodies using a low assay cut-off. Screening test concordance using paired plasma and serum samples was high, particularly for subjects with higher level antibodies. Refrigeration of samples for one week did not significantly affect assay results, while repeated freeze-thaw cycles caused a decrement in signal level. CONCLUSION Serum and plasma samples gave concordant results in the majority of cases, particularly for specimens with higher-level antibodies. High-level HLA antibodies were present in most individuals for over 13 years. PMID:18980615
Bok, Sangho; Korampally, Venumadhav; Darr, Charles M; Folk, William R; Polo-Parada, Luis; Gangopadhyay, Keshab; Gangopadhyay, Shubhra
2013-03-15
We report a simple, robust fluorescence biosensor for the ultra-sensitive detection of Clostridium botulinum Neurotoxin Type A (BoNT/A) in complex, real-world media. High intrinsic signal amplification was achieved through the combined use of ultra-bright, photostable dye-doped nanoparticle (DOSNP) tags and high surface area nanoporous organosilicate (NPO) thin films. DOSNP with 22 nm diameter were synthesized with more than 200 times equivalent free dye fluorescence and conjugated to antibodies with average degree of substitution of 90 dyes per antibody, representing an order of magnitude increase compared with conventional dye-labeled antibodies. The NPO films were engineered to form constructive interference at the surface where fluorophores were located. In addition, DOSNP-labeled antibodies with NPO films increased surface roughness causing diffuse scattering resulting in 24% more scattering intensity than dye-labeled antibody with NPO films. These substrates were used for immobilization of capture antibodies against BoNT/A, which was further quantified by DOSNP-labeled signal antibodies. The combination of optical effects enhanced the fluorescence and, therefore, the signal-to-noise ratio significantly. BoNT/A was detected in PBS buffer down to 21.3 fg mL(-1) in 4 h. The assay was then extended to several complex media and the four-hour detection limit was found to be 145.8 fg mL(-1) in orange juice and 164.2 fg mL(-1) in tap water, respectively, demonstrating at least two orders of magnitude improvement comparing to the reported detection limit of other enzyme-linked immunosorbent assays (ELISA). This assay, therefore, demonstrates a novel method for rapid, ultra-low level detection of not only BoNT/A, but other analytes as well. Copyright © 2012 Elsevier B.V. All rights reserved.
Human herpesvirus 8 infection among various population groups in southern Israel.
Margalith, Miriam; Chatlynne, Louise G; Fuchs, Efrat; Owen, Carole; Lee, Cheng-Rei Ruth; Yermiyahu, Tikva; Whitman, James E; Ablashi, Dharam V
2003-12-15
To compare the prevalence of antibodies to human herpesvirus 8 (HHV-8) or Kaposi sarcoma-associated herpesvirus among Israeli and Ethiopian subjects. Serum samples were obtained from 98 Israeli Jewish students aged 18-30 years, 100 HIV-1-seronegative Ethiopian immigrants to Israel of the same age, and 100 HIV-1-seronegative Ethiopian children 1-12 years old upon their arrival in southern Israel. Plasma samples were obtained from 3 hospitalized patients with multicentric Castleman disease (MCD) as positive controls. All serum samples were tested for antibodies to both latent and lytic antigens. Antibodies to the lytic antigens and the latency-associated nuclear antigen (LANA) of HHV-8 were detected by enzyme linked immunosorbent assay and by immunofluorescence assay. HHV-8 DNA from serum or plasma samples was detected by polymerase chain reaction analysis. Antibodies to HHV-8 LANA were detected in 2.9% of the Israeli subjects aged 18-30 years and in 26% of the Ethiopian subjects from both age groups tested. Antibodies to the lytic antigens were detected in all 3 MCD patients, in 4% of the Ethiopian children, and in 2% of the 18- to 30-year-old Ethiopians. No antibodies to the lytic antigens were detected in the Israeli students. HHV-8 DNA was detected in all 3 MCD patients and in 2 of 4 of the Ethiopian children positive for the lytic antigens. HHV-8 is highly prevalent in Ethiopian immigrants to Israel as compared with Israeli students. Antibodies to HHV-8 in Ethiopia are acquired before puberty. The results of this study indicate the association of HHV-8 with MCD, as has been documented by many other researchers.
Decorte, Inge; Van Breedam, Wander; Van der Stede, Yves; Nauwynck, Hans J; De Regge, Nick; Cay, Ann Brigitte
2014-06-17
Oral fluid collected by means of ropes has the potential to replace serum for monitoring and surveillance of important swine pathogens. Until now, the most commonly used method to collect oral fluid is by hanging a cotton rope in a pen. However, concerns about the influence of rope material on subsequent immunological assays have been raised. In this study, we evaluated six different rope materials for the collection of oral fluid and the subsequent detection of total and PRRSV-specific antibodies of different isotypes in oral fluid collected from PRRSV-vaccinated and infected pigs. An initial experiment showed that IgA is the predominant antibody isotype in porcine saliva. Moreover, it was found that synthetic ropes may yield higher amounts of IgA, whereas all rope types seemed to be equally suitable for IgG collection. Although IgA is the predominant antibody isotype in porcine oral fluid, the PRRSV-specific IgA-based IPMA and ELISA tests were clearly not ideal for sensitive detection of PRRSV-specific IgA antibodies. In contrast, PRRSV-specific IgG in oral fluids was readily detected in PRRSV-specific IgG-based IPMA and ELISA tests, indicating that IgG is a more reliable isotype for monitoring PRRSV-specific antibody immunity in vaccinated/infected animals via oral fluids with the currently available tests. Since PRRSV-specific IgG detection seems more reliable than PRRSV-specific IgA detection for monitoring PRRSV-specific antibody immunity via oral fluids, and since all rope types yield equal amounts of IgG, it seems that the currently used cotton ropes are an appropriate choice for sample collection in PRRSV monitoring.
Anti-DNA antibodies--quintessential biomarkers of SLE.
Pisetsky, David S
2016-02-01
Antibodies that recognize and bind to DNA (anti-DNA antibodies) are serological hallmarks of systemic lupus erythematosus (SLE) and key markers for diagnosis and disease activity. In addition to common use in the clinic, anti-DNA antibody testing now also determines eligibility for clinical trials, raising important questions about the nature of the antibody-antigen interaction. At present, no 'gold standard' for serological assessment exists, and anti-DNA antibody binding can be measured with a variety of assay formats, which differ in the nature of the DNA substrates and in the conditions for binding and detection of antibodies. A mechanism called monogamous bivalency--in which high avidity results from simultaneous interaction of IgG Fab sites with a single polynucleotide chain--determines anti-DNA antibody binding; this mechanism might affect antibody detection in different assay formats. Although anti-DNA antibodies can promote pathogenesis by depositing in the kidney or driving cytokine production, they are not all alike, pathologically, and anti-DNA antibody expression does not necessarily correlate with active disease. Levels of anti-DNA antibodies in patients with SLE can vary over time, distinguishing anti-DNA antibodies from other pathogenic antinuclear antibodies. Elucidation of the binding specificities and the pathogenic roles of anti-DNA antibodies in SLE should enable improvements in the design of informative assays for both clinical and research purposes.
Serological Detection of Viral Infections in Captive Wild Cats from Costa Rica
Blanco, Kinndle; Peña, Roberto; Hernández, Carmen; Jiménez, Mauricio; Araya, Luis Nazario; Romero, Juan José; Dolz, Gaby
2011-01-01
Serum samples from a total of 44 wildcats, 28 margays (Leopardus wiedii), 10 ocelots (Leopardus pardalis), four jaguaroundis (Herpailurus yaguaroundi), one oncilla (Leopardus tigrina), and one jaguar (Panthera onca) were obtained between January 2001 and August 2002 from the Profelis Centre for rehabilitation of wild felids, located in the northwestern region of Costa Rica. Forty three samples were tested for antibodies against feline immunodeficiency virus (FIV) and p27 antigen of feline leukemia virus (FeLV), 42 samples for antibodies against feline parvovirus (FPV), and 30 for antibodies against feline calicivirus (FCV). None of the samples contained detectable antibodies against FIV or p27 antigen of FeLV, all samples contained antibodies against FPV, and one sample contained antibodies against FCV. PMID:21547230
Serological detection of viral infections in captive wild cats from costa rica.
Blanco, Kinndle; Peña, Roberto; Hernández, Carmen; Jiménez, Mauricio; Araya, Luis Nazario; Romero, Juan José; Dolz, Gaby
2011-04-03
Serum samples from a total of 44 wildcats, 28 margays (Leopardus wiedii), 10 ocelots (Leopardus pardalis), four jaguaroundis (Herpailurus yaguaroundi), one oncilla (Leopardus tigrina), and one jaguar (Panthera onca) were obtained between January 2001 and August 2002 from the Profelis Centre for rehabilitation of wild felids, located in the northwestern region of Costa Rica. Forty three samples were tested for antibodies against feline immunodeficiency virus (FIV) and p27 antigen of feline leukemia virus (FeLV), 42 samples for antibodies against feline parvovirus (FPV), and 30 for antibodies against feline calicivirus (FCV). None of the samples contained detectable antibodies against FIV or p27 antigen of FeLV, all samples contained antibodies against FPV, and one sample contained antibodies against FCV.
NASA Astrophysics Data System (ADS)
Jiang, Ning
Accurately measuring the immune repertoire sequence composition, diversity, and abundance is important in studying repertoire response in infections, vaccinations, and cancer immunology. Using molecular identifiers (MIDs) to tag mRNA molecules is an effective method in improving the accuracy of immune repertoire sequencing (IR-seq). However, it is still difficult to use IR-seq on small amount of clinical samples to achieve a high coverage of the repertoire diversities. This is especially challenging in studying infections and vaccinations where B cell subpopulations with fewer cells, such as memory B cells or plasmablasts, are often of great interest to study somatic mutation patterns and diversity changes. Here, we describe an approach of IR-seq based on the use of MIDs in combination with a clustering method that can reveal more than 80% of the antibody diversity in a sample and can be applied to as few as 1,000 B cells. We applied this to study the antibody repertoires of young children before and during an acute malaria infection. We discovered unexpectedly high levels of somatic hypermutation (SHM) in infants and revealed characteristics of antibody repertoire development in young children that would have a profound impact on immunization in children.
Detection of Unexpected High Correlations between Balance Calibration Loads and Load Residuals
NASA Technical Reports Server (NTRS)
Ulbrich, N.; Volden, T.
2014-01-01
An algorithm was developed for the assessment of strain-gage balance calibration data that makes it possible to systematically investigate potential sources of unexpected high correlations between calibration load residuals and applied calibration loads. The algorithm investigates correlations on a load series by load series basis. The linear correlation coefficient is used to quantify the correlations. It is computed for all possible pairs of calibration load residuals and applied calibration loads that can be constructed for the given balance calibration data set. An unexpected high correlation between a load residual and a load is detected if three conditions are met: (i) the absolute value of the correlation coefficient of a residual/load pair exceeds 0.95; (ii) the maximum of the absolute values of the residuals of a load series exceeds 0.25 % of the load capacity; (iii) the load component of the load series is intentionally applied. Data from a baseline calibration of a six-component force balance is used to illustrate the application of the detection algorithm to a real-world data set. This analysis also showed that the detection algorithm can identify load alignment errors as long as repeat load series are contained in the balance calibration data set that do not suffer from load alignment problems.
Varied distribution of RhD epitopes in the Indian population.
Kulkarni, S S; Gupte, S C; Vasantha, K; Mohanty, D; Ghosh, K
2007-01-01
Inhabited by more than 4000 caste and tribal groups, India has an extremely heterogenous population. For thousands of years many tribal groups have practised endogamy and are practically genetically isolated. Traditionally, polyclonal anti-D reagent has been used for RhD typing; though monoclonal antibodies are increasingly being used. As a result, blood banks find it difficult to assign the RhD status to an increasing number of people. As monoclonal anti-D typing reagents may not detect all RhD antigen epitopes, we studied the RhD antigen epitope heterogeneity in different population groups in India. Red cells of 5315 RhD-positive individuals belonging to different castes and tribes of India were tested with 30 different epitope-specific monoclonal anti-D antibodies. No single monoclonal antibody could detect all RhD-positive red cells detected by polyclonal antisera. The highest proportion of D antigen was detected by LHM 76/55 and BRAD-8 (98%) monoclonal antibodies. We need to determine the correct mix of monoclonal antibodies that will detect nearly all RhD antigens detected by polyclonal anti-D sera. Similarly, before accepting monoclonal anti-D for therapeutic use, it would be necessary to determine the appropriate ones for use in the Indian population.
Wiley, L M; Obasaju, M F; Overstreet, J W; Cross, N L; Hanson, F W; Chang, R J
1987-08-01
The authors have developed an extension of the sperm penetration assay for detecting serum immunoglobulins to sperm antigens that are transferred to the plasma membrane of a sperm-penetrated hamster oocyte. After the hamster oocytes have been scored for sperm penetration by observing for the presence of swollen sperm heads, they are incubated in serum followed by either a 20-minute treatment with rhodamine-conjugated protein A (which binds to most subclasses of IgA, IgG, and IgM) or a 2-hour incubation in guinea pig serum (complement). Positive fluorescence indicates that the serum contains antibodies to sperm antigens that were transferred to the surface of an oocyte during gamete fusion. Complement-mediated lysis indicates that the immunoglobulin that is bound can also fix complement. The advantages of this assay for detection of serum antisperm antibodies are that it is an extension of a widely used assay, is rapid and requires readily available reagents and equipment, can detect most subclasses of IgA, IgG, and IgM, detects antibodies to those sperm antigens that may be transferred to the oocyte during fertilization, and indicates whether the detected antisperm antibodies can mediate complement-dependent lysis of the fertilized oocyte.
Buehler, Jason; Lager, Kelly; Vincent, Amy; Miller, Cathy; Thacker, Eileen; Janke, Bruce
2014-03-01
A potential mechanism by which highly pathogenic avian Influenza A virus subtype H5N1 could more readily infect human beings is through the infection of and adaptation in pigs. To detect the occurrence of such infection, monitoring of pig populations through serological screening would be highly desirable. In the current study, hemagglutination inhibition assays were able to detect antibodies against H5N1 developed in pigs, but because of antigenic variation between clades, the use of multiple virus strains were required. Whole recombinant virus and recombinant hemagglutinin antigen enzyme-linked immunosorbent assays (ELISAs) were generated that could detect antibody against multiple H5N1 strains, but which also detected antibody against endemic swine influenza viruses. A recombinant hemagglutinin antigen-based ELISA was as effective as the whole virus antigen ELISAs in detecting antibody against the H5N1 virus strains used and eliminated nearly all of the cross-reactivity with non-H5N1 virus antibody. The current study also highlighted the difficulty in establishing a decision (cutoff) value that would effectively counterbalance nonspecific reactivity against sensitivity. The results provide important information and considerations for the development of serological screening assays for highly pathogenic avian H5N1 viruses.
Koren, Eugen; Smith, Holly W; Shores, Elizabeth; Shankar, Gopi; Finco-Kent, Deborah; Rup, Bonita; Barrett, Yu-Chen; Devanarayan, Viswanath; Gorovits, Boris; Gupta, Shalini; Parish, Thomas; Quarmby, Valerie; Moxness, Michael; Swanson, Steven J; Taniguchi, Gary; Zuckerman, Linda A; Stebbins, Christopher C; Mire-Sluis, Anthony
2008-04-20
The appropriate evaluation of the immunogenicity of biopharmaceuticals is of major importance for their successful development and licensure. Antibodies elicited by these products in many cases cause no detectable clinical effects in humans. However, antibodies to some therapeutic proteins have been shown to cause a variety of clinical consequences ranging from relatively mild to serious adverse events. In addition, antibodies can affect drug efficacy. In non-clinical studies, anti-drug antibodies (ADA) can complicate interpretation of the toxicity, pharmacokinetic (PK) and pharmacodynamic (PD) data. Therefore, it is important to develop testing strategies that provide valid assessments of antibody responses in both non-clinical and clinical studies. This document provides recommendations for antibody testing strategies stemming from the experience of contributing authors. The recommendations are intended to foster a more unified approach to antibody testing across the biopharmaceutical industry. The strategies proposed are also expected to contribute to better understanding of antibody responses and to further advance immunogenicity evaluation.
Lorey, Martina; Adler, Belinda; Yan, Hong; Soliymani, Rabah; Ekström, Simon; Yli-Kauhaluoma, Jari; Laurell, Thomas; Baumann, Marc
2015-05-19
A new read-out method for antibody arrays using laser desorption/ionization-mass spectrometry (LDI-MS) is presented. Small, photocleavable reporter molecules with a defined mass called "mass-tags" are used for detection of immunocaptured proteins from human plasma. Using prostate specific antigen (PSA), a biomarker for prostate cancer, as a model antigen, a high sensitivity generic detection methodology based immunocapture with a primary antibody and with a biotin labeled secondary antibody coupled to mass-tagged avidin is demonstrated. As each secondary antibody can bind several avidin molecules, each having a large number of mass-tags, signal amplification can be achieved. The developed PSA sandwich mass-tag analysis method provided a limit of detection below 200 pg/mL (6 pM) for a 10 μL plasma sample, well below the clinically relevant cutoff value of 3-4 ng/mL. This brings the limit of detection (LOD) for detection of intact antigens with matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS) down to levels comparable to capture by anti-peptide antibodies selected reaction monitoring (SISCAPA SRM) and enzyme linked immunosorbent assay (ELISA), as 6 pM corresponds to a maximal amount of 60 amol PSA captured on-spot. We propose the potential use of LDI (laser desorption/ionization) with mass-tag read-out implemented in a sandwich assay format for low abundant and/or early disease biomarker detection.
Antibody Microarray for E. coli O157:H7 and Shiga Toxin in Microtiter Plates.
Gehring, Andrew G; Brewster, Jeffrey D; He, Yiping; Irwin, Peter L; Paoli, George C; Simons, Tawana; Tu, Shu-I; Uknalis, Joseph
2015-12-04
Antibody microarray is a powerful analytical technique because of its inherent ability to simultaneously discriminate and measure numerous analytes, therefore making the technique conducive to both the multiplexed detection and identification of bacterial analytes (i.e., whole cells, as well as associated metabolites and/or toxins). We developed a sandwich fluorescent immunoassay combined with a high-throughput, multiwell plate microarray detection format. Inexpensive polystyrene plates were employed containing passively adsorbed, array-printed capture antibodies. During sample reaction, centrifugation was the only strategy found to significantly improve capture, and hence detection, of bacteria (pathogenic Escherichia coli O157:H7) to planar capture surfaces containing printed antibodies. Whereas several other sample incubation techniques (e.g., static vs. agitation) had minimal effect. Immobilized bacteria were labeled with a red-orange-fluorescent dye (Alexa Fluor 555) conjugated antibody to allow for quantitative detection of the captured bacteria with a laser scanner. Shiga toxin 1 (Stx1) could be simultaneously detected along with the cells, but none of the agitation techniques employed during incubation improved detection of the relatively small biomolecule. Under optimal conditions, the assay had demonstrated limits of detection of ~5.8 × 10⁵ cells/mL and 110 ng/mL for E. coli O157:H7 and Stx1, respectively, in a ~75 min total assay time.
Pegu, Poonam; Vaccari, Monica; Gordon, Shari; Keele, Brandon F; Doster, Melvin; Guan, Yongjun; Ferrari, Guido; Pal, Ranajit; Ferrari, Maria Grazia; Whitney, Stephen; Hudacik, Lauren; Billings, Erik; Rao, Mangala; Montefiori, David; Tomaras, Georgia; Alam, S Munir; Fenizia, Claudio; Lifson, Jeffrey D; Stablein, Donald; Tartaglia, Jim; Michael, Nelson; Kim, Jerome; Venzon, David; Franchini, Genoveffa
2013-02-01
The recombinant canarypox vector, ALVAC-HIV, together with human immunodeficiency virus (HIV) gp120 envelope glycoprotein, has protected 31.2% of Thai individuals from HIV acquisition in the RV144 HIV vaccine trial. This outcome was unexpected, given the limited ability of the vaccine components to induce CD8(+) T-cell responses or broadly neutralizing antibodies. We vaccinated macaques with an immunization regimen intended to mimic the RV144 trial and exposed them intrarectally to a dose of the simian immunodeficiency virus SIV(mac251) that transmits few virus variants, similar to HIV transmission to humans. Vaccination induced anti-envelope antibodies in all vaccinees and CD4(+) and CD8(+) T-cell responses. Three of the 11 macaques vaccinated with ALVAC-SIV/gp120 were protected from SIV(mac251) acquisition, but the result was not significant. The remaining vaccinees were infected and progressed to disease. The magnitudes of vaccine-induced SIV(mac251)-specific T-cell responses and binding antibodies were not significantly different between protected and infected animals. However, sera from protected animals had higher avidity antibodies to gp120, recognized the variable envelope regions V1/V2, and reduced SIV(mac251) infectivity in cells that express high levels of α(4)β(7) integrins, suggesting a functional role of antibodies to V2. The current results emphasize the utility of determining the titer of repeated mucosal challenge in the preclinical evaluation of HIV vaccines.
Pegu, Poonam; Vaccari, Monica; Gordon, Shari; Keele, Brandon F.; Doster, Melvin; Guan, Yongjun; Ferrari, Guido; Pal, Ranajit; Ferrari, Maria Grazia; Whitney, Stephen; Hudacik, Lauren; Billings, Erik; Rao, Mangala; Montefiori, David; Tomaras, Georgia; Alam, S. Munir; Fenizia, Claudio; Lifson, Jeffrey D.; Stablein, Donald; Tartaglia, Jim; Michael, Nelson; Kim, Jerome; Venzon, David
2013-01-01
The recombinant canarypox vector, ALVAC-HIV, together with human immunodeficiency virus (HIV) gp120 envelope glycoprotein, has protected 31.2% of Thai individuals from HIV acquisition in the RV144 HIV vaccine trial. This outcome was unexpected, given the limited ability of the vaccine components to induce CD8+ T-cell responses or broadly neutralizing antibodies. We vaccinated macaques with an immunization regimen intended to mimic the RV144 trial and exposed them intrarectally to a dose of the simian immunodeficiency virus SIVmac251 that transmits few virus variants, similar to HIV transmission to humans. Vaccination induced anti-envelope antibodies in all vaccinees and CD4+ and CD8+ T-cell responses. Three of the 11 macaques vaccinated with ALVAC-SIV/gp120 were protected from SIVmac251 acquisition, but the result was not significant. The remaining vaccinees were infected and progressed to disease. The magnitudes of vaccine-induced SIVmac251-specific T-cell responses and binding antibodies were not significantly different between protected and infected animals. However, sera from protected animals had higher avidity antibodies to gp120, recognized the variable envelope regions V1/V2, and reduced SIVmac251 infectivity in cells that express high levels of α4β7 integrins, suggesting a functional role of antibodies to V2. The current results emphasize the utility of determining the titer of repeated mucosal challenge in the preclinical evaluation of HIV vaccines. PMID:23175374
Surya, Ravindran; Tejasvi, Bobbili; Shenoi, Shrutakirthi D; Pai, Sathish; Rao, Chythra; Rao, Raghavendra
2017-01-01
Background: Subepidermal autoimmune bullous diseases (sAIBD) are diverse of conditions with clinicopathological overlap. Circulating autoantibodies in the serum can be demonstrated using indirect immunofluorescence (IIF) microscopy. Artificially split normal human skin is considered as an optimum substrate for the demonstration of anti-basement membrane zone (BMZ) antibodies using IIF in sAIBD; it not only helps to detect the presence of circulating antibodies in the serum but also helps to subclassify these conditions into “roof” and “floor” binding disorders. Aim: In this study, we evaluated the utility of IIF to detect anti-BMZ antibodies in the blister fluid of patients with sAIBD. Materials and Methods: Twenty-two patients with a clinical diagnosis of sAIBD were enrolled in the study. IIF of serum and blister fluid were done simultaneously using salt-split skin as a substrate. Results: Anti-BMZ antibodies could be detected in the blister fluid using IIF in all patients in the study group. Limitation: We could not do enzyme-linked immunosorbent assay of blister fluid. This would have given us the quantitative data of circulating antibodies in the blister fluid. Conclusion: Blister fluid offers an alternate source for the detection of autoantibodies in patients with sAIBD. It may be of particular help in children and in elderly with poor venous access. PMID:29263541
Dutta, S K; Mattingly, B L; Shankarappa, B
1989-10-01
The antibody response and the antibody reactivity to component antigens of Ehrlichia risticii were studied in horses with induced Potomac horse fever. These horses had no detectable antibodies to E. risticii in their preinoculation (PrI) sera by indirect fluorescent-antibody assay and enzyme-linked immunosorbent assay (ELISA). All the horses exhibited typical disease features following experimental infection and responded with specific antibodies, as measured by ELISA and indirect fluorescent-antibody assay. A primary antibody response was detected in 70% of the horses, while a secondary-type antibody response was detected in 30% of the horses by ELISA. In the primary antibody response, a distinct titer was observed at 2 weeks postinoculation (PI), when the immunoglobulin M (IgM)/IgG ratio was 2 to 5, and the overall antibody titer peaked at 6 to 8 weeks PI. The secondary-type antibody response exhibited a characteristic titer at 1 week PI, the IgM and IgG titers were about equal at 2 weeks PI, and the overall antibody titer peaked at 6 weeks PI. A transient depression in the IgG response at 4 weeks PI was observed in both response types. The antibody was maintained at a high titer for over a year in all horses. Western immunoblot reactivity showed that the antisera collected from these infected horses at 4 to 5 weeks PI recognized some or all of the six major E. risticii component antigens (70, 55, 51, 44, 33, and 28 kilodaltons), all of which were apparent surface components. The 6- to 8-week PI antisera recognized up to 16 component antigens, including 9 major antigens (110, 86, 70, 55, 51, 49, 44, 33, and 28 kilodaltons). However, the PrI sera of these horses showed reactivity at various intensities with one to seven of the component antigens. There was no apparent correlation between this reactivity pattern and the subsequent antibody response types.
Application of surface plasmon resonance biosensor for the detection of Candida albicans
NASA Astrophysics Data System (ADS)
Yodmongkol, Sirasa; Thaweboon, Sroisiri; Thaweboon, Boonyanit; Puttharugsa, Chokchai; Sutapun, Boonsong; Amarit, Ratthasart; Somboonkaew, Armote; Srikhirin, Toemsak
2016-02-01
In this study, surface plasmon resonance imaging (SPR imaging) was developed for the detection of Candida albicans which is a causal agent of oral infection. The detection was based on the sandwich assay. The capture antibody was covalently immobilized on the mixed self assemble monolayers (SAMs). The ratio of mixed SAMs between 11-mercaptoundecanoic acid and 3-mercaptopropanol was varied to find the optimal ratio for use as a sensor surface. The results showed that the suitable surface for C. albicans detection was SAM of carboxylic (mixed SAMs 1:0), even though mixed SAMs 1:40 had a high detection signal in comparison to mixed SAMs 1:0, but the non-specific signal was higher. The detection limit was 107 cells/ml for direct detection, and was increased to 106 cells/ml with sandwich antibody. The use of polyclonal C. albicans antibody as capture and sandwich antibody showed good selectivity against the relevant oral bacteria including Escherichia coli, Streptococcus mutan, Staphylococcus aureus, β-streptococci, and Lactobacillus casei. SPR platform in this study could detect C. albicans from the mixed microbial suspension without requirement of skillful technician. This SPR imaging biosensor could be applied for Candida identification after cultivation.
Production of monoclonal antibody for the detection of meat and bone meal in animal feed.
Kim, Shin-Hee; Huang, Tung-Shi; Seymour, Thomas A; Wei, Cheng-i; Kempf, Stephen C; Bridgman, C Roger; Clemens, Roger A; An, Haejung
2004-12-15
For the detection of prohibited meat and bone meal (MBM) in animal feed, monoclonal antibodies (MAbs) were raised against heat-stable h-caldesmon purified from bovine intestinal smooth muscle. The obtained hybridoma cells were screened against extracts of the bovine MBM and heat-treated smooth muscle, and MAb 5E12 was identified as having the best performance. Antibody 5E12 did not react with animal feed, milk product, plant proteins, and other ingredients used for commercial animal feed except for the gelatin. This antibody diluted to 100-fold was able to detect MBM mixed in animal feed at 0.05% in an ELISA, and it showed strong affinity toward bovine smooth muscle autoclaved at 130 degrees C. Therefore, this antibody can be used in the ELISA system for field testing of the presence of MBM in animal feed.
Experimental results of antigliadin antibodies detection using long period fiber grating
NASA Astrophysics Data System (ADS)
Corres, J. M.; Matias, I. R.; Goicoechea, J.; Arregui, F. J.; Viegas, D.; Araújo, F. M.; Santos, J. L.
2008-04-01
In this work a new nano-biofilm is proposed for the detection of celiac disease (CD). A long-period fiber grating (LPFG) is used as a transducer and the surface of the fiber is coated with a precursor layer of SiO2-nanospheres using the electrostatic self-assembly technique (ESA). This layer has been designed in order to create a substrate of high porosity where the gliadins could be deposited. Under the presence of specific antibodies antigliadin antibodies (AGA) the refractive index of the overlay changes giving a detectable shift in the resonance wavelength of the LPFG. Concentrations as low as 5 ppm were detected.
Botulinum toxin detection using AlGaN /GaN high electron mobility transistors
NASA Astrophysics Data System (ADS)
Wang, Yu-Lin; Chu, B. H.; Chen, K. H.; Chang, C. Y.; Lele, T. P.; Tseng, Y.; Pearton, S. J.; Ramage, J.; Hooten, D.; Dabiran, A.; Chow, P. P.; Ren, F.
2008-12-01
Antibody-functionalized, Au-gated AlGaN /GaN high electron mobility transistors (HEMTs) were used to detect botulinum toxin. The antibody was anchored to the gate area through immobilized thioglycolic acid. The AlGaN /GaN HEMT drain-source current showed a rapid response of less than 5s when the target toxin in a buffer was added to the antibody-immobilized surface. We could detect a range of concentrations from 1to10ng/ml. These results clearly demonstrate the promise of field-deployable electronic biological sensors based on AlGaN /GaN HEMTs for botulinum toxin detection.
Fernandez, José-Carlos; Billecocq, Agnès; Durand, Jean Paul; Cêtre-Sossah, Catherine; Cardinale, Eric; Marianneau, Philippe; Pépin, Michel; Tordo, Noël
2012-01-01
Rift Valley fever (RVF) is an emerging zoonosis in Africa which has spread to Egypt, the Arabian Peninsula, Madagascar, and Comoros. RVF virus (RVFV) (Bunyaviridae family, Phlebovirus genus) causes a wide range of symptoms in humans, from benign fever to fatal hemorrhagic fever. Ruminants are severely affected by the disease, which leads to a high rate of mortality in young animals and to abortions and teratogenesis in pregnant females. Diagnostic tests include virus isolation and genome or antibody detection. During RVFV infection, the nucleoprotein encapsidating the tripartite RNA genome is expressed in large amounts and raises a robust antibody response, while the envelope glycoproteins elicit neutralizing antibodies which play a major role in protection. Much less is known about the antigenicity/immunogenicity of the nonstructural protein NSs, which is a major virulence factor. Here we have developed a competitive enzyme-linked immunosorbent assay (ELISA) enabling detection of low levels of NSs-specific antibodies in naturally infected or vaccinated ruminants. Detection of the NSs antibodies was validated by Western blotting. Altogether, our data showed that the NSs antibodies were detected in only 55% of animals naturally infected by RVFV, indicating that NSs does not induce a consistently high immune response. These results are discussed in light of differentiation between infected and vaccinated animals (DIVA) tests distinguishing naturally infected animals and those vaccinated with NSs-defective vaccines. PMID:22072723
Fernandez, José-Carlos; Billecocq, Agnès; Durand, Jean Paul; Cêtre-Sossah, Catherine; Cardinale, Eric; Marianneau, Philippe; Pépin, Michel; Tordo, Noël; Bouloy, Michèle
2012-01-01
Rift Valley fever (RVF) is an emerging zoonosis in Africa which has spread to Egypt, the Arabian Peninsula, Madagascar, and Comoros. RVF virus (RVFV) (Bunyaviridae family, Phlebovirus genus) causes a wide range of symptoms in humans, from benign fever to fatal hemorrhagic fever. Ruminants are severely affected by the disease, which leads to a high rate of mortality in young animals and to abortions and teratogenesis in pregnant females. Diagnostic tests include virus isolation and genome or antibody detection. During RVFV infection, the nucleoprotein encapsidating the tripartite RNA genome is expressed in large amounts and raises a robust antibody response, while the envelope glycoproteins elicit neutralizing antibodies which play a major role in protection. Much less is known about the antigenicity/immunogenicity of the nonstructural protein NSs, which is a major virulence factor. Here we have developed a competitive enzyme-linked immunosorbent assay (ELISA) enabling detection of low levels of NSs-specific antibodies in naturally infected or vaccinated ruminants. Detection of the NSs antibodies was validated by Western blotting. Altogether, our data showed that the NSs antibodies were detected in only 55% of animals naturally infected by RVFV, indicating that NSs does not induce a consistently high immune response. These results are discussed in light of differentiation between infected and vaccinated animals (DIVA) tests distinguishing naturally infected animals and those vaccinated with NSs-defective vaccines.
Nguyen, Xuan Duc; Dengler, Thomas; Schulz-Linkholt, Monika; Klüter, Harald
2011-02-03
Transfusion-related acute lung injury (TRALI) is a severe complication related with blood transfusion. TRALI has usually been associated with antibodies against leukocytes. The flow cytometric granulocyte immunofluorescence test (Flow-GIFT) has been introduced for routine use when investigating patients and healthy blood donors. Here we describe a novel tool in the automation of the Flow-GIFT that enables a rapid screening of blood donations. We analyzed 440 sera from healthy female blood donors for the presence of granulocyte antibodies. As positive controls, 12 sera with known antibodies against anti-HNA-1a, -b, -2a; and -3a were additionally investigated. Whole-blood samples from HNA-typed donors were collected and the test cells isolated using cell sedimentation in a Ficoll density gradient. Subsequently, leukocytes were incubated with the respective serum and binding of antibodies was detected using FITC-conjugated antihuman antibody. 7-AAD was used to exclude dead cells. Pipetting steps were automated using the Biomek NXp Multichannel Automation Workstation. All samples were prepared in the 96-deep well plates and analyzed by flow cytometry. The standard granulocyte immunofluorescence test (GIFT) and granulocyte agglutination test (GAT) were also performed as reference methods. Sixteen sera were positive in the automated Flow-GIFT, while five of these sera were negative in the standard GIFT (anti-HNA 3a, n = 3; anti-HNA-1b, n = 1) and GAT (anti-HNA-2a, n = 1). The automated Flow-GIFT was able to detect all granulocyte antibodies, which could be only detected in GIFT in combination with GAT. In serial dilution tests, the automated Flow-GIFT detected the antibodies at higher dilutions than the reference methods GIFT and GAT. The Flow-GIFT proved to be feasible for automation. This novel high-throughput system allows an effective antigranulocyte antibody detection in a large donor population in order to prevent TRALI due to transfusion of blood products.
Urusov, Alexandr E; Gubaidullina, Miliausha K; Petrakova, Alina V; Zherdev, Anatoly V; Dzantiev, Boris B
2017-12-06
A new kind of competitive immunochromatographic assay is presented. It is based on the use of a test strip loaded with (a) labeled specific antibodies, (b) a hapten-protein conjugate at the control zone, and (c) antibodies interacting with the specific antibodies in the analytical zone. In the case where a sample does not contain the target antigen (hapten), all labeled antibodies remain in the control zone because of the selected ratio of reactants. The analytical zone remains colorless because the labeled antibodies do not reach it. If an antigen is present in the sample, it interferes with the binding of the specific antibodies in the control zone and knocks them out. Some of these antibodies pass the control zone to form a colored line in the analytical zone. The intensity of the color is directly proportional to the amount of the target antigen in the sample. The assay has an attractive feature in that an appearance in coloration is more easily detected visually than a decoloration. Moreover, the onset of coloration is detectable at a lower concentration than a decoloration. The new detection scheme was applied to the determination of the mycotoxin deoxynivalenol. The visual limit of detection is 2 ng·mL -1 in corn extracts (35 ng per gram of sample). With the same reagents, this is lower by a factor of 60 than the established test strip. The assay takes only 15 min. This new kind of assay has wide potential applications for numerous low molecular weight analytes. Graphical abstract Competitive immunochromatography with direct analyte-signal dependence is proposed. It provides a 60-fold decrease of the detection limit for mycotoxin deoxynivalenol. The analyte-antibody-label complexes move along the immobilized antigen (control zone) and bind with anti-species antibodies (test zone).
Prince, Harry E; Seaton, Brent L; Matud, Jose L; Batterman, Hollis J
2015-03-01
Since first reported in the Americas in December 2013, chikungunya virus (CHIKV) infections have been documented in travelers returning from the Caribbean, with many cases identified by CHIKV antibody and/or RNA testing at our laboratory. We used our large data set to characterize the relationship between antibody titers and RNA detection and to estimate IgM persistence. CHIKV RNA was measured by nucleic acid amplification and CHIKV IgG/IgM by indirect immunofluorescence. Of the 1,306 samples submitted for RNA testing in January through September 2014, 393 (30%) were positive; for 166 RNA-positive samples, CHIKV antibody testing was also ordered, and 84% were antibody negative. Of the 6,971 sera submitted for antibody testing in January through September 2014, 1,811 (26%) were IgM positive; 1,461 IgM positives (81%) were also IgG positive. The relationship between the CHIKV antibody titers and RNA detection was evaluated using 376 IgM-positive samples (138 with RNA testing ordered and 238 deidentified and tested for RNA). RNA detection showed no significant association with the IgM titer but was inversely related to the IgG titer; 63% of the IgG negative sera were RNA positive, compared to 36% of sera with low IgG titers (1:10 to 1:80) and 16% with IgG titers of ≥1:160. Using second-sample results from 62 seroconverters, we estimated that CHIKV IgM persists for 110 days (95% confidence interval, 78 to 150 days) after the initial antibody-negative sample. These findings indicate that (i) RNA detection is more sensitive than antibody detection early in CHIKV infection, (ii) in the absence of RNA results, the IgG titer of the IgM-positive samples may be a useful surrogate for viremia, and (iii) CHIKV IgM persists for approximately 4 months after symptom onset. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Yuan, B; Ai, C-X; Yuan, L; Gao, W; Hu, J-P; Chen, J; Ren, W-Z
2014-09-12
This study aimed to prepare monoclonal antibody of feline calicivirus (FCV) and identify its basic biological characteristics. Saturated ammonium sulfate precipitation, combined differential centrifugation, and cesium chloride density gradient centrifugation were used for the purification of FCV. The purified FCV was used as antigen to immunize BALB/c mice. The hybridoma lines of anti-FCV monoclonal antibodies were established using cell fusion and hybridoma screening techniques. The subtypes of the monoclonal antibody were identified. The results showed that 3 strains of hybridoma cell lines stably secreted anti-FCV monoclonal antibody; they were named as D8, E5, and H4. The D8 and E5 were IgM subtype antibodies, and H4 was IgG2b subtype antibody. The monoclonal antibody obtained shared no cross-reactivity with feline parvovirus, canine parvovirus, and canine distemper virus. According to the different recognition sites of 2 monoclonal antibodies E5 and H4 to the FCV, they were used to coat microtiter plates and prepare 2 enzyme-labeled secondary antibodies to establish double-antibody sandwich enzyme-linked immunosorbent assay detecting method.
1993-01-25
10 DISCUSSION ............................................... 14 FIELD TESTS OF ANTIBODY DETECTION OF HEAT SHOCK PROTEIN ACCUMULATION IN... TESTS OF ANTIBODY DETECTION OF HEAT SHOCK PROTEIN ACCUMULATION IN ASIAN CLAMS (CORBICULA FLUMINEA) INTRODUCTION The Trinity River flows through...the utility of induction of heat shock proteins as an indicator of stress in another test organism, the Asian clam (Corbicula fluminea). This organism
Mahler, Michael; Satoh, Minoru; Hudson, Marie; Baron, Murray; Chan, Jason Y F; Chan, Edward K L; Wick, James; Fritzler, Marvin J
2014-07-01
Antinuclear antibodies (ANA) occur in up to 95% of patients with systemic sclerosis (SSc). In most, SSc-associated antibodies are detected (i.e., centromere, topoisomerase I, RNA polymerase III, PM/Scl, Ro52/TRIM21, and U1RNP). Ribonuclease P protein subunit p25, (Rpp25) is an autoantigenic component of the Th/To complex. The contribution of anti-Th/To and anti-Rpp25 antibodies to ANA positivity in patients with SSc remains unknown. Sera from 873 patients with SSc were tested for ANA, and SSc-associated antibodies were measured. Samples without antibodies to extractable nuclear antigens (ENA; n = 53, ANA+/ENA-), were analyzed by immunoprecipitation (IP) and metabolically labeled proteins and for anti-Rpp25 antibodies (n = 50) by a chemiluminescent immunoassay (CLIA) and Rpp25 ELISA. Anti-Th/To antibodies occurred in 19/53 (36%), as determined by IP, and were the most common autoantibody in ANA+/ENA- SSc. Of those samples, 50/53 were available for additional testing by CLIA and ELISA. Anti-Rpp25 antibodies were detected in 12 (24% CLIA) or 10 (20% ELISA) of 50 patients. Receiver-operating characteristic curve analysis showed similar discrimination between Th/To IP-positive (n = 19) and -negative samples (n = 31) by CLIA and ELISA (area under the curve 0.90 vs 0.87; p = 0.6691). The positive percent agreement between IP and CLIA or ELISA was 12/19 (63.2%, 95% CI 38.4-83.7%) or 10/19 (52.6%, 95% CI 73.3-94.2%), respectively. Negative percent agreement was 100% for both assays. Autoantibodies to the Th/To autoantigen are important in patients with SSc who have been considered negative for SSc-specific or SSc-associated antibodies by widely available commercial assays. Rpp25 can be considered a major target of anti-Th/To antibodies. Assays detecting anti-Th/To and anti-Rpp25 antibodies may be important in SSc.
Photocleavable DNA Barcoding Antibodies for Multiplexed Protein Analysis in Single Cells.
Ullal, Adeeti V; Weissleder, Ralph
2015-01-01
We describe a DNA-barcoded antibody sensing technique for single cell protein analysis in which the barcodes are photocleaved and digitally detected without amplification steps (Ullal et al., Sci Transl Med 6:219, 2014). After photocleaving the unique ~70 mer DNA barcodes we use a fluorescent hybridization technology for detection, similar to what is commonly done for nucleic acid readouts. This protocol offers a simple method for multiplexed protein detection using 100+ antibodies and can be performed on clinical samples as well as single cells.
Detection of antibodies to Trypanosoma cruzi in the South American opossum (Didelphis marsupialis).
Luckins, A G; Miles, M A
1982-01-01
Stocks of Trypanosoma cruzi belonging to two different zymodemes, one usually associated with silvatic reservoir hosts and the other not normally found in wild reservoir hosts, were used as sources of diagnostic antigens in enzyme-linked immunosorbent assays for the detection of antibodies to T. cruzi in Didelphis marsupialis. Both antigen preparations reacted with antibodies in sera from animals found to be infected by conventional parasitological techniques and also in sera from a proportion of the remaining animals in which it was not possible to detect trypanosomes.
García, Antonio A.; Pirez-Gomez, Miguel A.; Pech-Pacheco, José L.; Mendez-Galvan, Jorge F.; Machain-Williams, Carlos; Talavera-Aguilar, Lourdes; Espinosa-Carrillo, José H.; Duarte-Villaseñor, Miriam M.; Be-Ortiz, Christian; Espinosa-de los Monteros, Luz E.; Castillo-Pacheco, Ariel; Garcia-Rejon, Julian E.
2017-01-01
Antibody detection and accurate diagnosis of tropical diseases is essential to help prevent the spread of disease. However, most detection methods lack cost-effectiveness and field portability, which are essential features for achieving diagnosis in a timely manner. To address this, 3D-printed oblate spheroid sample chambers were fabricated to measure green light scattering of gold nanoparticles using an optical caustic focus to detect antibodies. Scattering signals of 20–200 nm gold nanoparticles using a green laser were compared to green light emitting diode (LED) light source signals and to Mie theory. The change in signal from 60 to 120 nm decreased in the order of Mie Theory > optical caustic scattering > 90° scattering. These results suggested that conjugating 60 nm gold nanoparticles and using an optical caustic system to detect plasmonic light scattering, would result in a sensitive test for detecting human antibodies in serum. Therefore, we studied the light scattering response of conjugated gold nanoparticles exposed to different concentrations of anti-protein E antibody, and a feasibility study of 10 human serum samples using dot blot and a handheld optical caustic-based sensor device. The overall agreement between detection methods suggests that the new sensor concept shows promise to detect gold nanoparticle aggregation in a homogeneous assay. Further testing and protocol optimization is needed to draw conclusions on the positive and negative predictive values for this new testing system. PMID:28817080
2017-04-06
recognized by mAb 6D8 when assayed by immunofluourescent antibody staining of transfected cells (Figure 5A). As expected, ELISA of cell culture... ELISA using whole EBOV antigen. Mep1 elicited no detectable antibody response after two vaccinations and only a low response after three...vaccinations. Mep2 elicited a detectable response after two vaccinations with a rise in ELISA antibody titer after three vaccinations (Figure 5C
An evaluation of antibodies and clinical resistance to salmon calcitonin
Singer, Frederick R.; Aldred, J. Phillip; Neer, Robert M.; Krane, Stephen M.; Potts, John T.; Bloch, Kurt J.
1972-01-01
21 patients with Paget's disease of bone and one with osteoporosis were studied to detect development of antibodies to salmon calcitonin during chronic therapy. Antibody titers ranged from 1:40 to 1:30,000 in plasma obtained after treatment of 11 patients. Radio-immunoelectrophoresis revealed that the antibodies were restricted to the γG class. One patient, W. O., with Paget's disease initially responded to treatment with a decrease in bone turnover, but later became resistant to the hormone in association with the appearance of a very high titer (1:30,000) of antibody against salmon calcitonin. A 1:10 dilution of his plasma was shown to completely inactivate 20 mMRC units/ml of salmon calcitonin as detected by bioassay in rats; slight inactivation was detected at a 1:200 dilution. All other patients continued to respond to salmon calcitonin despite the development of antibody to the hormone in ten cases. No evidence of systemic allergic reactions or other toxicity was found in any patient. The data suggest that although antibody formation may occur in as many as 50% of patients treated with salmon calcitonin, this antibody response is unlikely to be of clinical significance in most patients. However, in an occasional patient, a marked antibody response may occur which interferes with the therapeutic use of the hormone. Images PMID:4674133
Highly sensitive detection of target molecules using a new fluorescence-based bead assay
NASA Astrophysics Data System (ADS)
Scheffler, Silvia; Strauß, Denis; Sauer, Markus
2007-07-01
Development of immunoassays with improved sensitivity, specificity and reliability are of major interest in modern bioanalytical research. We describe the development of a new immunomagnetic fluorescence detection (IM-FD) assay based on specific antigen/antibody interactions and on accumulation of the fluorescence signal on superparamagnetic PE beads in combination with the use of extrinsic fluorescent labels. IM-FD can be easily modified by varying the order of coatings and assay conditions. Depending on the target molecule, antibodies (ABs), entire proteins, or small protein epitopes can be used as capture molecules. The presence of target molecules is detected by fluorescence microscopy using fluorescently labeled secondary or detection antibodies. Here, we demonstrate the potential of the new assay detecting the two tumor markers IGF-I and p53 antibodies in the clinically relevant concentration range. Our data show that the fluorescence-based bead assay exhibits a large dynamic range and a high sensitivity down to the subpicomolar level.
[Automatic pre-transfusion serology].
Wattar, B; Govaerts, A
1975-12-01
This paper describes an automated apparatus combining Rosenfield's and Lalezari's antibody screening and identification basic technics. PVP bromelin and low ionic strength acid polybren channels are used; agglutinates are decanded; the remaining cells are hemolyzed and the optical density is then measured through a colorimeter and recorded on a chart; speed is of 40 samples an hour. This machine was also used for irregular antibody screening and identification. Sensitivity is shown to be equal to that of manual technics for ABO, Lewis, Lutheran as well as K, S, M, Kpb, Xga, U and Vel antibodies detection. Nevertheless, a much greater sensitivity is achieved (titers 3 to 10 times higher) than by manual technics for Rh, -k, S, Fya antibodies detection. Polybren channel is suitable for anti-Rh, Duffy, I and M (human detection; bromelin channel however, has a greater sensitivity for other specificities. Anti-M and anti-N sera from rabbits were shown to be non specific when using this machine. Over almost 15 000 sera tested, no antibody (detected by manual techniques) escaped the automated screening. This antibody detection machine was applied to compatibility tests prior to transfusion. (21 480 units were tested. aimed to be transfused to 5 611 patients). A third, PVP without bromelin, was set in parallel in order not to let escape any anti-M, even a weak one. The sera distributor was slaved to the cells distributor so that the whole procedure was automated. Furthermore, each serum was tested against red cells to be transfused, but also against the patient's own red cells to be transfused, but also against the patient's own red cells and against two selected red cells panels, so as to ensure irregular antibody detection at the same time. Using this machine, 3 to 4% of the cell samples were rejected, i.e. more than with usual techniques. All manually detected antibodies were identified, but also some others, which showed only weak reactions by classical techniques. Total results can be obtained within 20 to 30 minutes, which is quite rapid, compared to techniques using for example antiglobulin tests.
Liu, Shuangshuang; Li, Shasha; Zhang, Yang; Wang, Ye; Zhu, Yumeng; Wang, Bin; Chen, Zhi-Nan
2017-01-01
The immunoglobulin superfamily member CD147 is a widely expressed glycoprotein that occurs in both a membrane-spanning and soluble form. Sandwich ELISA is a powerful tool for analyzing soluble antigens. The aim of the present study was to obtain a highly specific polyclonal antibody against human CD147 that can be used for sandwich ELISA analysis. Expression of recombinant CD147 by a eukaryotic expression system was used to immunize rabbits to obtain antiserum. A highly specific polyclonal antibody that was able to detect soluble CD147 in sandwich ELISA was obtained by antigen-immunoaffinity chromatography purification. The purity of rabbit anti-CD147 polyclonal antibodies was ~99%, and ELISA analysis was able to determine the titer of the rabbit anti-CD147 polyclonal antibodies at 1:512,000. The lowest concentration of the standard CD147 antigen that the sandwich ELISA was able to detect was 31.25 pg/ml. The sandwich ELISA system was composed of anti-hepatoma HAb18 monoclonal antibodies and purified rabbit anti-CD147 polyclonal antibodies. The present study demonstrated that antigen-immunoaffinity chromatography may be a good technique for the purification of polyclonal antibodies, which may be used to detect antigen in sandwich ELISAs. PMID:28487989
Prevalence of antibody to hepatitis E virus among wild sika deer, Cervus nippon, in Japan.
Matsuura, Y; Suzuki, M; Yoshimatsu, K; Arikawa, J; Takashima, I; Yokoyama, M; Igota, H; Yamauchi, K; Ishida, S; Fukui, D; Bando, G; Kosuge, M; Tsunemitsu, H; Koshimoto, C; Sakae, K; Chikahira, M; Ogawa, S; Miyamura, T; Takeda, N; Li, T C
2007-01-01
We examined 976 sika deer serum samples, 159 liver tissue samples and 88 stool samples collected from 16 prefectures in Japan, and performed ELISA and RT-PCR assays to detect antibodies to HEV and HEV RNA, respectively. Although 25 (2.6%) of 976 samples were positive for anti-HEV IgG, the antibody titers were very low. The OD values ranged between 0.018 and 0.486, forming a single distribution rather than a bimodal distribution, suggesting that the antibody detected in this study was not induced by HEV infection, or that deer have low sensitivity to HEV. HEV RNA was not detected in these samples, also suggesting that deer may not play a role as an HEV reservoir.
Cai, Huijing; Wang, Yixian; Yu, Yun; Mirkin, Michael V; Bhakta, Snehasis; Bishop, Gregory W; Joshi, Amit A; Rusling, James F
2015-06-16
Quartz nanopipettes have recently been employed for resistive-pulse sensing of Au nanoparticles (AuNP) and nanoparticles with bound antibodies. The analytical signal in such experiments is the change in ionic current caused by the nanoparticle translocation through the pipette orifice. This paper describes resistive-pulse detection of cancer biomarker (Vascular Endothelial Growth Factor-C, VEGF-C) through the use of antibody-modified AuNPs and nanopipettes. The main challenge was to differentiate between AuNPs with attached antibodies for VEGF-C and antigen-conjugated particles. The zeta-potentials of these types of particles are not very different, and, therefore, carefully chosen pipettes with well-characterized geometry were necessary for selective detection of VEGF-C.
Cai, Huijing; Wang, Yixian; Yu, Yun; Mirkin, Michael V.; Bhakta, Snehasis; Bishop, Gregory W.; Joshi, Amit A.; Rusling, James F.
2015-01-01
Quartz nanopipettes have recently been employed for resistive-pulse sensing of Au nanoparticles (AuNP) and nanoparticles with bound antibodies. The analytical signal in such experiments is the change in ionic current caused by the nanoparticle translocation through the pipette orifice. This paper describes resistive-pulse detection of cancer biomarker (Vascular Endothelial Growth Factor-C, VEGF-C) through the use of antibody-modified AuNPs and nanopipettes. The main challenge was to differentiate between AuNPs with attached antibodies for VEGF-C and antigen-conjugated particles. The zeta-potentials of these types of particles are not very different, and, therefore, carefully chosen pipettes with well-characterized geometry were necessary for selective detection of VEGF-C. PMID:26040997
Serological tests for detecting Rift Valley fever viral antibodies in sheep from the Nile Delta.
Scott, R M; Feinsod, F M; Allam, I H; Ksiazek, T G; Peters, C J; Botros, B A; Darwish, M A
1986-01-01
To determine the accuracy of serological methods in detecting Rift Valley fever (RVF) viral antibodies, we examined serum samples obtained from 418 sheep in the Nile Delta by using five tests. The plaque reduction neutralization test (PRNT) was considered the standard serological method against which the four other tests were compared. Twenty-four serum samples had RVF viral antibodies detected by PRNT. Hemagglutination inhibition and enzyme-linked immunosorbent assay antibodies to RVF virus were also present in the same 24 serum samples. Indirect immunofluorescence was less sensitive in comparison with PRNT, and complement fixation was the least sensitive. These results extend observations made with laboratory animals to a large field-collected group of Egyptian sheep. PMID:3533977
Urquiza, Mauricio; Sánchez, Ricardo; Amaya, Jairo; León, Sandra; Acosta, Jenny; Patarroyo, Manuel A.; Camargo, Milena; Patarroyo, Manuel E.
2008-01-01
A serological test for the detection of human papillomavirus (HPV) infection in females at risk of developing cervical cancer could be based on conserved L1 peptides with low levels of antigenicity specifically recognized by antibodies from patients with cervical lesions infected with high-risk HPV (HR-HPV) types. The aim was to assess the ability of L1 peptides 18283, 18294, and 18301 compared with the ability of virus-like particles (VLPs) to identify these infections in females. A total of 391 HPV-infected female volunteers were interviewed, and peripheral blood and cervical cells were obtained for detection of anti-HPV antibodies and HPV DNA; all of the patients had a Pap smear test; 287 patients were referred for colposcopy or biopsy, according to gynecological criteria. The level of agreement, as determined by the use of the Lin coefficient (rho value), showed that 75 to 83% of females with HR-HPV DNA-positive cervical lesions had antibodies that recognized VLPs and peptide 18283, 18294, or 18301, while 15 to 23% of the HPV DNA-negative females with a normal cytology had antibodies that recognized these three peptides and 45% had antibodies that recognized VLPs. The rate of agreement between peptides and VLPs for antibody detection was higher for patients with HPV DNA-positive cervical lesions. Peptides 18283, 18294, and 18301 showed similar sensitivities for the detection of HR-HPV DNA-positive cervical lesions and were more specific than VLPs. Peptide 18301 might be detecting protective antibodies in HPV DNA-negative females with atypical squamous cells of undetermined significance. These peptides could be useful for the design of a serology test for the detection of HR-HPV infection in females with cervical lesions and at risk of cervical cancer. PMID:18799706
Mertens, Marc; Vatansever, Zati; Mrenoshki, Slavcho; Krstevski, Kiril; Stefanovska, Jovana; Djadjovski, Igor; Cvetkovikj, Iskra; Farkas, Robert; Schuster, Isolde; Donnet, Fabien; Comtet, Loic; Tordo, Noël; Ben Mechlia, Mohamed; Balkema-Buschmann, Anne; Mitrov, Dine; Groschup, Martin H.
2015-01-01
Background There are only few assays available for the detection of Crimean-Congo Hemorrhagic Fever Virus (CCHFV)-specific antibodies in animals, and data about diagnostic sensitivity and specificity are incompletely documented for most of these tests. This is unfortunate since CCHFV antibodies in animals can be used as indicator for virus circulation in a geographic area and therewith potential risk of human exposure. This paper therefore reports on a novel ELISA for the detection of CCHFV-specific antibodies in cattle and on its application for testing ruminant sera from the Former Yugoslav Republic of Macedonia. Principal Findings A highly sensitive and specific ELISA was developed to detect CCHFV-specific IgG antibodies in cattle. The assay was validated by using 503 negative serum samples from a country where CCHFV has never been detected until now, and by using 54 positive serum samples. The positive sera were verified by using two commercially available assays (for testing human serum) which we have adapted for use in animals. The sensitivity of the novel ELISA was 98% and its specificity 99%. The presence of Hyalomma ticks was demonstrated in the Former Yugoslav Republic of Macedonia and depending on the region antibody prevalence rates up to 80% were detected in the cattle population. Conclusion This article describes a fully validated, highly sensitive and specific ELISA for the detection of CCHFV-specific IgG antibodies in cattle. Using this assay, CCHFV-specific antibodies were detected for the first time in cattle in the Former Yugoslav Republic of Macedonia, giving evidence for an active circulation of this virus in the country. Supporting this conclusion, the occurrence of the main vector of CCHFV was demonstrated in the present work for the first time in Former Yugoslav Republic of Macedonia. PMID:25742017
Domagała, A; Kamieniczna, M; Kowalczyk, D; Kurpisz, M
1998-09-01
Antisperm antibodies induced in prepubertal boys with testicular failures were characterized by using four techniques of antibody detection. The reactivity of circulating antisperm antibodies in prepubertal boys and the reactivity of antibodies in sera samples of adult fertile and infertile males were compared against the same sperm antigenic pools (live or fixed spermatozoa, or sperm antigenic extracts). The incidence of antisperm antibodies in sera samples of 69 prepubertal boys with testicular failures and 21 samples obtained from adult, male individuals was assessed by indirect immunobead binding test (IDIBT), flow cytometry measurement, enzyme-linked immunosorbent assay, and Western blotting. Immunoblot analysis was performed by using sperm extracts of glycosylated and deglycosylated solubilized membrane antigens. Sera samples were studied in a group composed of healthy prepubertal boys (n = 7) and prepubertal boys with testicular failures (n = 69). Applied tests of antibody detection revealed striking differences in a group of boys with testicular pathology. With IDIBT, 7% of the sera samples were found positive, whereas with flow cytometry measurement, 48% of the sera samples were positive. Immunosorbent assay (fixed sperm) indicated 32% positive cases in the same group. The sera samples were found to be positive in 65% of immunoblotting reactions with glycosylated antigens and in 70% of immunoblotting reactions with deglycosylated antigens. All applied detection assays were clearly negative on sera samples from fertile, adult males. Western immunoblotting indicated an immunodominant antigenic determinant of 58 kDa. Tests of antibody detection with the use of live sperm (IDIBT and flow cytometry measurements) presented low sensitivity (8% and 48%, respectively) in a group of prepubertal boys. This observation underlines the difficulties in assigning the prospective prognosis of future fertility status in prepubertal boys with antisperm antibodies.
Srila, Witsanu; Yuttavanichakul, Watcharin; Teamtisong, Kamonluck; Teaumroong, Neung; Boonkerd, Nantakorn; Tittabutr, Panlada
2017-01-01
A simple and reliable method for the detection of specific nitrogen-fixing bacteria in both free-living and bacteroid forms is essential for the development and application of biofertilizer. Traditionally, a polyclonal antibody generated from an immunized rabbit was used for detection. However, the disadvantages of using a polyclonal antibody include limited supply and cross-reactivity to related bacterial strains. This is the first report on the application of phage display technology for the generation of a rabbit recombinant monoclonal antibody for specific detection and monitoring of nitrogen-fixing bacteria in both free-living form and in plant nodules. Bradyrhizobium sp. DOA9, a broad host range soil bacteria, originally isolated from the root nodules of Aeschynomene americana in Thailand was used as a model in this study. A recombinant single-chain fragment variable (scFv) antibody library was constructed from the spleen of a rabbit immunized with DOA9. After three rounds of biopanning, one specific phage-displayed scFv antibody, designated bDOA9rb8, was identified. Specific binding of this antibody was confirmed by phage enzyme-linked immunosorbent assay (phage ELISA). The phage antibody could bind specifically to DOA9 in both free-living cells (pure culture) and bacteroids inside plant nodules. In addition to phage ELISA, specific and robust immunofluorescence staining of both free-living and bacteroid forms could also be observed by confocal-immunofluorescence imaging, without cross-reactivity with other tested bradyrhizobial strains. Moreover, specific binding of free scFv to DOA9 was also demonstrated by ELISA. This recombinant antibody can also be used for the study of the molecular mechanism of plant–microbe interactions in the future. PMID:28654662
Vu, Nguyen Xuan; Pruksametanan, Natcha; Srila, Witsanu; Yuttavanichakul, Watcharin; Teamtisong, Kamonluck; Teaumroong, Neung; Boonkerd, Nantakorn; Tittabutr, Panlada; Yamabhai, Montarop
2017-01-01
A simple and reliable method for the detection of specific nitrogen-fixing bacteria in both free-living and bacteroid forms is essential for the development and application of biofertilizer. Traditionally, a polyclonal antibody generated from an immunized rabbit was used for detection. However, the disadvantages of using a polyclonal antibody include limited supply and cross-reactivity to related bacterial strains. This is the first report on the application of phage display technology for the generation of a rabbit recombinant monoclonal antibody for specific detection and monitoring of nitrogen-fixing bacteria in both free-living form and in plant nodules. Bradyrhizobium sp. DOA9, a broad host range soil bacteria, originally isolated from the root nodules of Aeschynomene americana in Thailand was used as a model in this study. A recombinant single-chain fragment variable (scFv) antibody library was constructed from the spleen of a rabbit immunized with DOA9. After three rounds of biopanning, one specific phage-displayed scFv antibody, designated bDOA9rb8, was identified. Specific binding of this antibody was confirmed by phage enzyme-linked immunosorbent assay (phage ELISA). The phage antibody could bind specifically to DOA9 in both free-living cells (pure culture) and bacteroids inside plant nodules. In addition to phage ELISA, specific and robust immunofluorescence staining of both free-living and bacteroid forms could also be observed by confocal-immunofluorescence imaging, without cross-reactivity with other tested bradyrhizobial strains. Moreover, specific binding of free scFv to DOA9 was also demonstrated by ELISA. This recombinant antibody can also be used for the study of the molecular mechanism of plant-microbe interactions in the future.
Barquero, Nuria; Gomez-Lucia, Esperanza; Arjona, Alvaro; Toural, Cristina; las Heras, Alfonso; Fernández-Garayzabal, José F.; Domenech, Ana
2013-01-01
The diagnosis of Small Ruminant Lentivirus (SRLV) is based on clinical signs, pathological lesions and laboratory testing. No standard reference test for the diagnosis of maedi visna has been validated up to the present, and it is puzzling that tests which detect antibodies against the virus and tests which detect the proviral genome may render opposite results. The aim of this study was to evaluate the presence in milk throughout a lactation period of specific antibodies by ELISA and of SRLV proviral DNA by a PCR of the highly conserved pol region. A six-month study was conducted with the milk of 28 ewes and 31 goats intensively reared. The percentage of animals with antibodies against SRLV increased throughout the study period. Seroprevalence in sheep was 28% at the beginning of the study and by the end it had increased up to 52.4%. In goats, initial seroprevalence of 5.6% increased to 16%. The percentage of PCR positive ewes was stable throughout the study period. Of the positive sheep, 21.4% were PCR-positive before antibodies could be detected and most of them became PCR-negative shortly after the first detection of antibodies. This might suggest that antibodies have a neutralizing effect. In addition, an equal percentage of sheep were always PCR-negative but either became ELISA-positive or was always ELISA-positive, which might support this hypothesis. On the other hand, the PCR results in goats did not follow any pattern and oscillated between 35.3% and 55.6% depending on the month. Most goats positive by PCR failed to develop antibodies in the 6 months tested. We may conclude that the infection and the antibody response to it follow a different trend in sheep and goats. PMID:24153063
Broadly neutralizing antibody specificities detected in the genital tract of HIV-1 infected women.
Mkhize, Nonhlanhla N; Durgiah, Raveshni; Ashley, Vicki; Archary, Derseree; Garrett, Nigel J; Karim, Quarraisha Abdool; Karim, Salim S Abdool; Moore, Penny L; Yates, Nicole; Passmore, Jo-Ann S; Tomaras, Georgia D; Morris, Lynn
2016-04-24
Broadly neutralizing antibodies (bNAbs) targeting conserved epitopes on the HIV envelope glycoprotein have been identified in blood from HIV-1 infected women. We investigated whether antibodies in the genital tract from these women share similar epitope specificities and functional profiles as those in blood. Immunoglobulin (Ig)G and IgA antibodies were isolated from cervicovaginal lavages or Softcups from 13 HIV-infected women in the CAPRISA cohort using Protein G and Peptide M, respectively. Binding antibodies to envelope antigens were quantified by ELISA and binding antibody multiplex assay. Neutralizing antibody titers and epitope targets were measured using the TZM-bl assay with Env-pseudotyped wild-type and mutated viruses. HIV-specific IgG, but not IgA, was detected in genital secretions and the ratio of total IgG to HIV-specific IgG was similar to plasma. HIV-specific IgG reacted with multiple envelope antigens, including V1V2, gp120, gp140 and gp41. Two women had high plasma titers of HIV-specific IgG3 which was also detected in their genital tract samples. IgG from the genital tract had neutralizing activity against both Tier 1 and Tier 2 primary HIV-isolates. Antibodies targeting well known glycan epitopes and the membrane proximal region of gp41 were detected in genital secretions, and matched specificities in plasma. Women with plasma bNAbs have overlapping specificities in their genital secretions, indicating that these predominantly IgG isotype antibodies may transudate from blood to the genital tract. These data provide evidence that induction of systemic HIV-specific bNAbs can lead to antiviral immunity at the portal of entry.
Prevalence of precore-defective mutant of hepatitis B virus in HBV carriers.
Niitsuma, H; Ishii, M; Saito, Y; Miura, M; Kobayashi, K; Ohori, H; Toyota, T
1995-08-01
Two hundred and seventy-three serum specimens from hepatitis B virus (HBV) carriers were examined for the presence of a characteristic one point mutation at nucleotide (nt) 1896 from the EcoRI site of the HBV genome in the precore region (the preC mutant) using restriction fragment length polymorphism (RFLP) analysis. This assay approach could detect preC mutants or wild-type sequences when either form constituted more than 10% of the total sample. Overall, 65.5% (76/116) of HBeAg-positive carriers had only the preC wild-type. All HBeAg-positive asymptomatic carriers (n = 14) had only the preC wild-type. In patients with chronic hepatitis B and in anti-HBe-positive asymptomatic carriers, increased prevalence of the preC mutant was associated with the development of anti-HBe antibodies and normalization of the serum alanine aminotransferase concentration. Furthermore, 27 (29.0%) of 93 HBeAg-negative carriers had unexpectedly preC wild-type sequences only. Direct sequencing of the HBV precore region of HBV specimens from 24 patients revealed no mutation at nt 1896, supporting the specificity of the RFLP analysis. These results suggest that RFLP analysis was accurate for the detection of the preC mutation and that the absence of serum HBeAg cannot be explained solely by the dominance of the preC mutant.
Label-free protein assay based on a nanomechanical cantilever array
NASA Astrophysics Data System (ADS)
Arntz, Y.; Seelig, J. D.; Lang, H. P.; Zhang, J.; Hunziker, P.; Ramseyer, J. P.; Meyer, E.; Hegner, M.; Gerber, Ch
2003-01-01
We demonstrate continuous label-free detection of two cardiac biomarker proteins (creatin kinase and myoglobin) using an array of microfabricated cantilevers functionalized with covalently anchored anti-creatin kinase and anti-myoglobin antibodies. This method allows biomarker proteins to be detected via measurement of surface stress generated by antigen-antibody molecular recognition. Reference cantilevers are used to eliminate thermal drifts, undesired chemical reactions and turbulences from injections of liquids by calculating differential deflection signals with respect to sensor cantilevers. The sensitivity achieved for myoglobin detection is below 20 µg ml-1. Both myoglobin and creatin kinase could be detected independently using cantilevers functionalized with the corresponding antibodies, in unspecific protein background. This approach permits the use of up to seven different antigen-antibody reactions simultaneously, including an additional thermomechanical and chemical in situ reference. Applications lie in the field of early and rapid diagnosis of acute myocardial infarction.
Effects of processing on the recovery of food allergens from a model dark chocolate matrix.
Khuda, Sefat E; Jackson, Lauren S; Fu, Tong-Jen; Williams, Kristina M
2015-02-01
To alleviate the risk to allergic consumers, it is crucial to improve factors affecting the detection of food allergens in processed chocolate products. This study evaluated processing effects on (1) recovery of peanut, egg, and milk allergens using five different extraction buffers, and (2) identification of specific allergenic proteins from extracts of incurred chocolate using allergen-specific antibodies and human allergic sera. Immunochemical staining with polyclonal antibodies showed that the addition of detergent or reducing agent improved extraction efficiency of peanut proteins, but not of egg and milk proteins. Tempering decreased antibody binding regardless of extractant. Detection of IgE-reactive peanut, egg, and milk allergens was differentially affected by tempering and extractant. Detection problems associated with matrix and processing effects may be overcome by the choice of extraction buffer and detecting antibody. Published by Elsevier Ltd.
Galay, Remil Linggatong; Matsuo, Tomohide; Hernandez, Emmanuel Pacia; Talactac, Melbourne Rio; Kusakisako, Kodai; Umemiya-Shirafuji, Rika; Mochizuki, Masami; Fujisaki, Kozo; Tanaka, Tetsuya
2018-04-01
Due to the continuous threat of ticks and tick-borne diseases to human and animal health worldwide, and the drawbacks of chemical acaricide application, many researchers are exploring vaccination as an alternative tick control method. Earlier studies have shown that host antibodies can circulate in the ticks, but it has not been confirmed whether these antibodies can be passed on to the eggs. We previously reported that ticks infesting rabbits immunized with a recombinant secretory ferritin of Haemaphysalis longicornis (HlFER2) had reduced egg production and hatching. Here we attempted to detect the presence of antibodies against HlFER2 in the ovary and eggs of female ticks through immunofluorescent visualization. Purified anti-HlFER2 antibodies or rabbit IgG for control was directly injected to engorged female H. longicornis. Ovaries and eggs after oviposition were collected and prepared for an indirect immunofluorescent antibody test. Positive fluorescence was detected in ovaries one day post-injection of anti-HlFER2 antibodies. Through silencing of Hlfer2 gene, we also determined whether the injected antibodies can specifically bind to native HlFER2. Immunofluorescence was observed in the oocytes of dsLuciferase control ticks injected with anti-HlFER2 antibodies, but not in the oocytes of Hlfer2-silenced ticks also injected with anti-HlFER2 antibodies. Our current findings suggest that host antibodies can be passed on to the oocytes, which is significant in formulating a vaccine that can disrupt tick reproduction. Copyright © 2017 Elsevier B.V. All rights reserved.
Pinon, J M; Thoannes, H; Gruson, N
1985-02-28
Enzyme-linked immuno-filtration assay is carried out on a micropore membrane. This doubly analytical technique permits simultaneous study of antibody specificity by immunoprecipitation and characterisation of antibody isotypes by immuno-filtration with enzyme-labelled antibodies. Recognition of the same T. gondii antigenic constituent by IgG, IgA, IgM or IgE antibodies produces couplets (IgG-IgM; IgG-IgA) or triplets (IgG-IgM-IgA; IgG-IgM-IgE) which identify the functional fractions of the toxoplasmosis antigen. In acquired toxoplasmosis, the persistence of IgM antibody long after infestation puts in question the implication of recent infestation normally linked to detection of this isotype. For sera of comparable titres, comparison of immunological profiles by the method described demonstrates disparities in the composition of the specific antibody content as expressed in international units. Use of the same method to detect IgM antibodies or distinguish between transmitted maternal IgG and IgG antibodies synthesised by the foetus or neonate makes a diagnosis of congenital toxoplasmosis possible in 85% of cases during the first few days of life. With the method described the diagnosis may be made on average 5 months earlier than with classical techniques. In the course of surveillance for latent congenital toxoplasmosis, the appearance of IgM or IgE antibodies raises the possibility of complications (hydrocephalus, chorioretinitis). After cessation of treatment, a rise in IgG antibodies indicating persistence of infection is detected earlier by the present than by classical methods.
Development and Evaluation of Single Domain Antibodies for Vaccinia and the L1 Antigen
Walper, Scott A.; Liu, Jinny L.; Zabetakis, Daniel; Anderson, George P.; Goldman, Ellen R.
2014-01-01
There is ongoing interest to develop high affinity, thermal stable recognition elements to replace conventional antibodies in biothreat detection assays. As part of this effort, single domain antibodies that target vaccinia virus were developed. Two llamas were immunized with killed viral particles followed by boosts with the recombinant membrane protein, L1, to stimulate the immune response for envelope and membrane proteins of the virus. The variable domains of the induced heavy chain antibodies were selected from M13 phage display libraries developed from isolated RNA. Selection via biopanning on the L1 antigen produced single domain antibodies that were specific and had affinities ranging from 4×10−9 M to 7.0×10−10 M, as determined by surface plasmon resonance. Several showed good ability to refold after heat denaturation. These L1-binding single domain antibodies, however, failed to recognize the killed vaccinia antigen. Useful vaccinia binding single domain antibodies were isolated by a second selection using the killed virus as the target. The virus binding single domain antibodies were incorporated in sandwich assays as both capture and tracer using the MAGPIX system yielding limits of detection down to 4×105 pfu/ml, a four-fold improvement over the limit obtained using conventional antibodies. This work demonstrates the development of anti-vaccinia single domain antibodies and their incorporation into sandwich assays for viral detection. It also highlights the properties of high affinity and thermal stability that are hallmarks of single domain antibodies. PMID:25211488
Wang, Yuzhen; Qi, Wenjin; Song, Yujun
2016-06-28
Platinum and carbon dot hybrid nanomaterials are prepared for visualized detection of phosphoproteins without the need for antibodies or enzymes. This new strategy can be used for colorimetric detection of phosphoproteins induced by protein kinase as well as protein phosphorylation sites on cell membranes.
He, Yanlong; Tian, Jianniao; Hu, Kun; Zhang, Juanni; Chen, Sheng; Jiang, Yixuan; Zhao, Yanchun; Zhao, Shulin
2013-11-13
In this work, an ultrasensitive fluorescent polarization immunoassay (FPIA) method based on the quantum dot/aptamer/antibody/gold nanoparticles ensemble has been developed for the detection of adenosine triphosphate (ATP). DNA hybridization is formed when ATP is present in the PBS solution containing the DNA-conjugated quantum dots (QDs) and antibody-AuNPs. The substantial sensitivity improvement of the antibody-AuNPs-enhanced method is mainly attributed to the slower rotation of fluorescent unit when QDs-labeled oligonucleotides hybridize with antibody modified the gold nanoparticle. As a result, the fluorescent polarization (FP) values of the system increase significantly. Under the optimal conditions, a linear response with ATP concentration is ranged from 8×10(-12) M to 2.40×10(-4) M. The detection limit reached as low as 1.8 pM. The developed work provides a sensitive and selective immunoassay protocol for ATP detection, which could be applied in more bioanalytical systems. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.
Fast detection of air contaminants using immunobiological methods
NASA Astrophysics Data System (ADS)
Schmitt, Katrin; Bolwien, Carsten; Sulz, Gerd; Koch, Wolfgang; Dunkhorst, Wilhelm; Lödding, Hubert; Schwarz, Katharina; Holländer, Andreas; Klockenbring, Torsten; Barth, Stefan; Seidel, Björn; Hofbauer, Wolfgang; Rennebarth, Torsten; Renzl, Anna
2009-05-01
The fast and direct identification of possibly pathogenic microorganisms in air is gaining increasing interest due to their threat for public health, e.g. in clinical environments or in clean rooms of food or pharmaceutical industries. We present a new detection method allowing the direct recognition of relevant germs or bacteria via fluorescence-labeled antibodies within less than one hour. In detail, an air-sampling unit passes particles in the relevant size range to a substrate which contains antibodies with fluorescence labels for the detection of a specific microorganism. After the removal of the excess antibodies the optical detection unit comprising reflected-light and epifluorescence microscopy can identify the microorganisms by fast image processing on a single-particle level. First measurements with the system to identify various test particles as well as interfering influences have been performed, in particular with respect to autofluorescence of dust particles. Specific antibodies for the detection of Aspergillus fumigatus spores have been established. The biological test system consists of protein A-coated polymer particles which are detected by a fluorescence-labeled IgG. Furthermore the influence of interfering particles such as dust or debris is discussed.
Prieto, José M; Balseiro, Ana; Casais, Rosa; Abendaño, Naiara; Fitzgerald, Liam E; Garrido, Joseba M; Juste, Ramon A; Alonso-Hearn, Marta
2014-08-01
The enzyme-linked immunosorbent assay (ELISA) is the diagnostic test most commonly used in efforts to control paratuberculosis in domestic ruminants. However, commercial ELISAs have not been validated for detecting antibodies against Mycobacterium avium subsp. paratuberculosis in wild animals. In this study, we compared the sensitivities and specificities of five ELISAs using individual serum samples collected from 41 fallow deer with or without histopathological lesions consistent with paratuberculosis. Two target antigenic preparations were selected, an ethanol-treated protoplasmic preparation obtained from a fallow deer M. avium subsp. paratuberculosis isolate (ELISAs A and B) and a paratuberculosis protoplasmic antigen (PPA3) (ELISAs C and D). Fallow deer antibodies bound to the immobilized antigens were detected by using a horseradish peroxidase (HRP)-conjugated anti-fallow deer IgG antibody (ELISAs A and C) or HRP-conjugated protein G (ELISAs B and D). A commercially available assay, ELISA-E, which was designed to detect M. avium subsp. paratuberculosis antibodies in cattle, sheep, and goats, was also tested. Although ELISAs A, C, and E had the same sensitivity (72%), ELISAs A and C were more specific (100%) for detecting fallow deer with lesions consistent with paratuberculosis at necropsy than was the ELISA-E (87.5%). In addition, the ELISA-A was particularly sensitive for detecting fallow deer in the latent stages of infection (62.5%). The antibody responses detected with the ELISA-A correlated with both the severity of enteric lesions and the presence of acid-fast bacteria in gut tissue samples. In summary, our study shows that the ELISA-A can be a cost-effective diagnostic tool for preventing the spread of paratuberculosis among fallow deer populations. Copyright © 2014, American Society for Microbiology. All Rights Reserved.
Prieto, José M.; Balseiro, Ana; Casais, Rosa; Abendaño, Naiara; Fitzgerald, Liam E.; Garrido, Joseba M.; Juste, Ramon A.
2014-01-01
The enzyme-linked immunosorbent assay (ELISA) is the diagnostic test most commonly used in efforts to control paratuberculosis in domestic ruminants. However, commercial ELISAs have not been validated for detecting antibodies against Mycobacterium avium subsp. paratuberculosis in wild animals. In this study, we compared the sensitivities and specificities of five ELISAs using individual serum samples collected from 41 fallow deer with or without histopathological lesions consistent with paratuberculosis. Two target antigenic preparations were selected, an ethanol-treated protoplasmic preparation obtained from a fallow deer M. avium subsp. paratuberculosis isolate (ELISAs A and B) and a paratuberculosis protoplasmic antigen (PPA3) (ELISAs C and D). Fallow deer antibodies bound to the immobilized antigens were detected by using a horseradish peroxidase (HRP)-conjugated anti-fallow deer IgG antibody (ELISAs A and C) or HRP-conjugated protein G (ELISAs B and D). A commercially available assay, ELISA-E, which was designed to detect M. avium subsp. paratuberculosis antibodies in cattle, sheep, and goats, was also tested. Although ELISAs A, C, and E had the same sensitivity (72%), ELISAs A and C were more specific (100%) for detecting fallow deer with lesions consistent with paratuberculosis at necropsy than was the ELISA-E (87.5%). In addition, the ELISA-A was particularly sensitive for detecting fallow deer in the latent stages of infection (62.5%). The antibody responses detected with the ELISA-A correlated with both the severity of enteric lesions and the presence of acid-fast bacteria in gut tissue samples. In summary, our study shows that the ELISA-A can be a cost-effective diagnostic tool for preventing the spread of paratuberculosis among fallow deer populations. PMID:24872517
VGKC complex antibodies in pediatric severe acute encephalitis: a study and literature review.
Lin, Jainn-Jim; Lin, Kuang-Lin; Hsia, Shao-Hsuan; Wang, Huei-Shyong; Chiu, Cheng-Hsun; CHEESE Study Group
2013-08-01
Antibodies to surface proteins like voltage-gated potassium channel (VGKC) complexes are increasingly found in different neurologic diseases and encephalitis in adults and recently, in children. Detecting such antibodies can help identify forms of encephalitis that may respond to immuno-therapies. However, there are few reports on VGKC complex antibodies in pediatric severe acute encephalitis. This study retrospectively reviewed antibodies to VGKC, leucine-rich glioma-inactivated 1 (Lgi1), and contactin-associated protein-like 2 (Caspr2) in 46 children with severe acute encephalitis. Published cases of VGKC complex antibodies in pediatric encephalitis in the period of 2000-2012 were also reviewed. Elevated VGKC complex antibodies (>100pM) were detected in one of the 46 children with severe acute encephalitis. The 4-year and 6-month-old girl presented with seizure and disturbed consciousness. Viral PCR/culture and serologic evidence of influenza A infection was noted. She also had complications of epilepsy, impaired cognition, and altered behavior and psychology. Antibodies to Lgi1 and Caspr2 were not detected. Ten previously published reports revealed that VGKC complex antibodies can occur in children with limbic encephalitis and acute or sub-acute encephalitis. The incidence of VGKC complex antibodies in pediatric severe acute encephalitis is not high with only one (2.2%) of 46 children in this study. And, this is the first report on the association of VGKC complex antibodies and patients with influenza A-related severe acute encephalitis. The mechanism of VGKC complex antibodies in pediatric severe acute encephalitis warrants further study. Copyright © 2012 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.
Moi, Meng Ling; Ami, Yasushi; Shirai, Kenji; Lim, Chang-Kweng; Suzaki, Yuriko; Saito, Yuka; Kitaura, Kazutaka; Saijo, Masayuki; Suzuki, Ryuji; Kurane, Ichiro; Takasaki, Tomohiko
2015-02-01
Infection with a dengue virus (DENV) serotype induces cross-reactive, weakly neutralizing antibodies to different dengue serotypes. It has been postulated that cross-reactive antibodies form a virus-antibody immune complex and enhance DENV infection of Fc gamma receptor (FcγR)-bearing cells. We determined whether infectious DENV-antibody immune complex is formed in vivo in marmosets after passive transfer of DENV-specific monoclonal antibody (mAb) and DENV inoculation and whether infectious DENV-antibody immune complex is detectable using FcγR-expressing cells. Marmosets showed that DENV-antibody immune complex was exclusively infectious to FcγR-expressing cells on days 2, 4, and 7 after passive transfer of each of the mAbs (mAb 4G2 and mAb 6B6C) and DENV inoculation. Although DENV-antibody immune complex was detected, contribution of the passively transferred antibody to overall viremia levels was limited in this study. The results indicate that DENV cross-reactive antibodies form DENV-antibody immune complex in vivo, which is infectious to FcγR-bearing cells but not FcγR-negative cells. © The American Society of Tropical Medicine and Hygiene.
NASA Technical Reports Server (NTRS)
Fattaey, A.; Lenz, L.; Consigli, R. A.; Spooner, B. S. (Principal Investigator)
1992-01-01
Eleven hybridoma cell lines producing monoclonal antibodies (MAbs) against intact budgerigar fledgling disease (BFD) virions were produced and characterized. These antibodies were selected for their ability to react with BFD virions in an enzyme-linked immunosorbent assay. Each of these antibodies was reactive in the immunofluorescent detection of BFD virus-infected cells. These antibodies immunoprecipitated intact virions and specifically recognized the major capsid protein, VP1, of the dissociated virion. The MAbs were found to preferentially recognize native BFD virus capsid protein when compared with denatured virus protein. These MAbs were capable of detecting BFD virus protein in chicken embryonated cell-culture lysates by dot-blot analysis.
Fukushi, Shuetsu; Fukuma, Aiko; Kurosu, Takeshi; Watanabe, Shumpei; Shimojima, Masayuki; Shirato, Kazuya; Iwata-Yoshikawa, Naoko; Nagata, Noriyo; Ohnishi, Kazuo; Ato, Manabu; Melaku, Simenew Keskes; Sentsui, Hiroshi; Saijo, Masayuki
2018-01-01
Since discovering the Middle East respiratory syndrome coronavirus (MERS-CoV) as a causative agent of severe respiratory illness in the Middle East in 2012, serological testing has been conducted to assess antibody responses in patients and to investigate the zoonotic reservoir of the virus. Although the virus neutralization test is the gold standard assay for MERS diagnosis and for investigating the zoonotic reservoir, it uses live virus and so must be performed in high containment laboratories. Competitive ELISA (cELISA), in which a labeled monoclonal antibody (MAb) competes with test serum antibodies for target epitopes, may be a suitable alternative because it detects antibodies in a species-independent manner. In this study, novel MAbs against the spike protein of MERS-CoV were produced and characterized. One of these MAbs was used to develop a cELISA. The cELISA detected MERS-CoV-specific antibodies in sera from MERS-CoV-infected rats and rabbits immunized with the spike protein of MERS-CoV. The MAb-based cELISA was validated using sera from Ethiopian dromedary camels. Relative to the neutralization test, the cELISA detected MERS-CoV-specific antibodies in 66 Ethiopian dromedary camels with a sensitivity and specificity of 98% and 100%, respectively. The cELISA and neutralization test results correlated well (Pearson's correlation coefficients=0.71-0.76, depending on the cELISA serum dilution). This cELISA may be useful for MERS epidemiological investigations on MERS-CoV infection. Copyright © 2017 Elsevier B.V. All rights reserved.
PERFORMANCE EVALUATION OF A PROTOTYPE ARCHITECT ANTIBODY ASSAY FOR BABESIA MICROTI.
Cheng, Kevin; Coller, Kelly E; Marohnic, Christopher C; Pfeiffer, Zachary A; Fino, James R; Elsing, Randee R; Bergsma, Janet; Marcinkus, Marilee A; Kar, Alak K; Gumbs, Orlando H; Otis, Kathy S; Fishpaugh, Jeffrey; Schultz, Phillip W; Pope, Mark R; Narvaez, Alfredo R; Wong, Susan J; Madison-Antenucci, Susan; Leary, Thomas P; Dawson, George J
2018-05-09
The tick-borne protozoan Babesia microti is responsible for more than 200 cases of transfusion-transmitted babesiosis (TTB) infection in the United States over the last 30 years. Measures to mitigate the risk of TTB include nucleic acid testing (NAT) and B. microti antibody testing. A fully automated prototype B. microti antibody test was developed on the ARCHITECT instrument. The specificity was determined to be 99.98% in volunteer blood donors (n=28,740) from areas considered as low endemic for B. microti The sensitivity of the prototype test was studied in experimentally-infected macaques; a total of 128 samples were detected compared to 125 with the indirect fluorescent antibody test (IFA), additionally, 83 (89.2%) of the PCR positive samples were detected compared to 81 (87.1%) using the IFA test. All PCR positive samples that tested negative in the prototype antibody test were pre-seroconversion period samples. Following seroconversion, periods of intermittent parasitemia occurred; 17 PCR negative samples drawn in-between PCR positive bleed dates, tested positive both by the prototype test (robust reactivity) and IFA (marginal reactivity) prior to the administration of therapeutic drugs, indicating that the PCR test failed to detect samples from persistently infected macaques. The prototype assay detected 56 of 58 (96.6%) human subjects diagnosed with clinical babesiosis by both PCR and IFA testing. Overall, the prototype anti-babesia assay provides a highly sensitive and specific test for the diagnosis of B. microti infection. While PCR is preferred for detection of window period parasitemia, antibody tests detect infected subjects during periods of low level parasitemia. Copyright © 2018 Cheng et al.
Evaluation of 5 different labeled polymer immunohistochemical detection systems.
Skaland, Ivar; Nordhus, Marit; Gudlaugsson, Einar; Klos, Jan; Kjellevold, Kjell H; Janssen, Emiel A M; Baak, Jan P A
2010-01-01
Immunohistochemical staining is important for diagnosis and therapeutic decision making but the results may vary when different detection systems are used. To analyze this, 5 different labeled polymer immunohistochemical detection systems, REAL EnVision, EnVision Flex, EnVision Flex+ (Dako, Glostrup, Denmark), NovoLink (Novocastra Laboratories Ltd, Newcastle Upon Tyne, UK) and UltraVision ONE (Thermo Fisher Scientific, Fremont, CA) were tested using 12 different, widely used mouse and rabbit primary antibodies, detecting nuclear, cytoplasmic, and membrane antigens. Serial sections of multitissue blocks containing 4% formaldehyde fixed paraffin embedded material were selected for their weak, moderate, and strong staining for each antibody. Specificity and sensitivity were evaluated by subjective scoring and digital image analysis. At optimal primary antibody dilution, digital image analysis showed that EnVision Flex+ was the most sensitive system (P < 0.005), with means of 8.3, 13.4, 20.2, and 41.8 gray scale values stronger staining than REAL EnVision, EnVision Flex, NovoLink, and UltraVision ONE, respectively. NovoLink was the second most sensitive system for mouse antibodies, but showed low sensitivity for rabbit antibodies. Due to low sensitivity, 2 cases with UltraVision ONE and 1 case with NovoLink stained false negatively. None of the detection systems showed any distinct false positivity, but UltraVision ONE and NovoLink consistently showed weak background staining both in negative controls and at optimal primary antibody dilution. We conclude that there are significant differences in sensitivity, specificity, costs, and total assay time in the immunohistochemical detection systems currently in use.
Development of antibodies against the rat brain somatostatin receptor.
Theveniau, M; Rens-Domiano, S; Law, S F; Rougon, G; Reisine, T
1992-05-15
Somatostatin (SRIF) is a neurotransmitter in the brain involved in the regulation of motor activity and cognition. It induces its physiological actions by interacting with receptors. We have developed antibodies against the receptor to investigate its structural properties. Rabbit polyclonal antibodies were generated against the rat brain SRIF receptor. These antibodies (F4) were able to immunoprecipitate solubilized SRIF receptors from rat brain and the cell line AtT-20. The specificity of the interaction of these antibodies with SRIF receptors was further demonstrated by immunoblotting. F4 detected SRIF receptors of 60 kDa from rat brain and adrenal cortex and the cell lines AtT-20, GH3, and NG-108, which express high densities of SRIF receptors. They did not detect immunoreactive material from rat liver or COS-1, HEPG, or CRL cells, which do not express functional SRIF receptors. In rat brain, 60-kDa immunoreactivity was detected by F4 in the hippocampus, cerebral cortex, and striatum, which have high densities of SRIF receptors. However, F4 did not interact with proteins from cerebellum and brain stem, which express few SRIF receptors. Immunoreactive material cannot be detected in rat pancreas or pituitary, which have been reported to express a 90-kDa SRIF receptor subtype. The selective detection of 60-kDa SRIF receptors by F4 indicates that the 60- and 90-kDa SRIF receptor subtypes are immunologically distinct. The availability of antibodies that selectively detect native and denatured brain SRIF receptors provides us with a feasible approach to clone the brain SRIF receptor gene(s).
Nakamura, Tsukasa; Ushigome, Hidetaka; Watabe, Kiyoko; Imanishi, Yui; Masuda, Koji; Matsuyama, Takehisa; Harada, Shumpei; Koshino, Katsuhiro; Iida, Taku; Nobori, Shuji; Yoshimura, Norio
2017-04-01
Immunocomplex capture fluorescence analysis (ICFA) is an attractive method to detect donor-specific anti-HLA antibodies (DSA) and HLA antigen complexes. Currently, antibody-mediated rejection (AMR) due to DSA is usually diagnosed by C4d deposition and serological DSA detection. Conversely, there is a discrepancy between these findings frequently. Thereupon, our graft ICFA technique may contribute to establish the diagnosis of AMR. Graft samples were obtained by a percutaneous needle biopsy. Then, the specimen was dissolved in PBS by the lysis buffer. Subsequently, HLA antigens were captured by anti-HLA beads. Then, DSA-HLA complexes were detected by PE-conjugated anti-human IgG antibodies, where DSA had already reacted with the allograft in vivo, analyzed by a Luminex system. A ratio (sample MFI/blank beads MFI) was calculated: ≥ 1.0 was determined as positive. We found that DSA-HLA complexes in the graft were successfully detected from only slight positive 1.03 to 79.27 in a chronic active AMR patient by graft ICFA. Next, positive graft ICFA had predicted the early phase of AMR (MFI ratio: 1.38) even in patients with no serum DSA. Finally, appropriate therapies for AMR deleted DSA deposition (MFI ratio from 0.3 to 0.7) from allografts. This novel application would detect early phase or incomplete pathological cases of AMR, which could lead to a correct diagnosis and initiation of appropriate therapies. Moreover, graft ICFA might address a variety of long-standing questions in terms of DSA. AMR: Antibody-mediated rejection; DSA: Donor-specific antibodies; ICFA: Immunocomplex capture fluorescence analysis.
Pujani, Mukta; Kushwaha, Shivani; Sethi, Neha; Beniwal, Anu; Shukla, Shailaja
2013-01-01
Systemic lupus erythematosus (SLE) is an autoimmune multisystem disease characterized by the development of antinuclear antibodies. Nowadays considered outdated, lupus erythematosus (LE) cell preparation served as a screening test for SLE for decades. However, the importance of discovering LE cells on routine cytology cannot be overemphasized. We report the case of a 30-year-old female in whom bone marrow aspiration (BMA) was performed during an investigative workup for pyrexia of unknown origin. The observation of LE cells in direct bone marrow smears (without the use of an anticoagulant) raised the suspicion of SLE, which was later confirmed by antinuclear antibody testing. In the present case, LE cells were observed on BMA performed for the investigation of fever of unknown origin. The unexpected observation of LE cells in BMA smears emphasizes the fact that good morphological observation of marrow aspirates can provide crucial clues to a previously unsuspected diagnosis.
Schmitz, H
1981-01-01
An improved fixation method for antigen detection in lymphoblastoid cells is described. Herpesvirus papio nuclear antigen (HUPNA) could be stained in several transformed lymphoid cell lines by anti-complement immunofluorescence (ACIF). Antibody to HUPNA was detected in many human sera containing antibodies to Epstein-Barr virus capsid and nuclear antigen (EBNA). Rheumatoid arthritis sera showed a high incidence of both anti-EBNA and anti-HUPNA antibodies.
Wang, Zhaopeng; Yu, Xuezhi; Ma, Licai; Liu, Hebing; Ding, Shuangyang; Wang, Zhanhui; Zhang, Xiya; Shen, Jianzhong; Wen, Kai
2018-05-23
In this work, high affinity polyclonal antibodies for ribavirin (RBV) from new haptens were prepared and were used to analyse RBV residues in chicken muscle, eggs and duck muscle. The new haptens were synthesised with different spacers, and the best antibody was obtained with an IC 50 value as low as 0.61 ng/mL in indirect competitive enzyme-linked immunosorbent assay (ELISA). The cross-reactivities with another five antiviral drugs including amantadine, rimantadine, moroxydine, zanamivir and oseltamivir were less than 0.1%, which indicated the good specificity of the antibody. An ELISA was developed based on the antibody and applied to detect RBV in multi-food matrices. The sample preparation prior to detection only needed simple dilution after trichloroacetic acid extraction. The limits of detection were 1.07, 1.18 and 1.03 μg/kg in chicken muscle, eggs and duck muscle, respectively. Recoveries ranged from 89.0% to 112.7% with coefficients of variation below 13.0%. Ten blind samples of chicken muscle were analysed simultaneously by ELISA and liquid chromatography-tandem mass spectrometry, and a good correlation between the methods was observed. The results indicated that the high affinity antibody could be applied for the simple and fast detection of RBV in multi-food matrices.
Barbee, Kristopher D.; Hsiao, Alexander P.; Roller, Eric E.; Huang, Xiaohua
2011-01-01
We report the development of a microfabricated electrophoretic device for assembling high-density arrays of antibody-conjugated microbeads for chip-based protein detection. The device consists of a flow cell formed between a gold-coated silicon chip with an array of microwells etched in a silicon dioxide film and a glass coverslip with a series of thin gold counter electrode lines. We have demonstrated that 0.4 and 1 μm beads conjugated with antibodies can be rapidly assembled into the microwells by applying a pulsed electric field across the chamber. By assembling step-wise a mixture of fluorescently labeled antibody-conjugated microbeads, we incorporated both spatial and fluorescence encoding strategies to demonstrate significant multiplexing capabilities. We have shown that these antibody-conjugated microbead arrays can be used to perform on-chip sandwich immunoassays to detect test antigens at concentrations as low as 40 pM (6 ng/mL). A finite element model was also developed to examine the electric field distribution within the device for different counter electrode configurations over a range of line pitches and chamber heights. This device will be useful for assembling high-density, encoded antibody arrays for multiplexed detection of proteins and other types of protein-conjugated microbeads for applications such as the analysis of protein-protein interactions. PMID:20820631
Detection of Planets Orbiting Sun-Like Stars
NASA Astrophysics Data System (ADS)
Marcy, Geoffrey W.; Butler, R. Paul
1996-12-01
During the past 11 months, astronomers have finally discovered planets orbiting Sun-like stars. A total of eight planets has been detected by the Doppler technique, and there are possible planets detected by astrometry around one other star. Some of the new planets exhibit properties similar to those in our Solar System. But many of them have properties that were unexpected. Several planets are more massive than Jupiter, and some orbit their host star in orbits smaller than Mercury's orbit. Equally unexpected is that three of these planets have noncircular orbits. Current theory of the formation of planetary systems is challenged to account for these new planetary properties, but several models are emerging, involving gravitational scattering of planetesimals and viscous or tidal decay of orbits. The occurrence rate of true analogs of our Solar System will soon be determined with the detection of long-period gas giants analogous to Jupiter.
Arur, Swathi; Schedl, Tim
2014-01-01
Post-translational modifications alter protein structure, affecting activity, stability, localization and/or binding partners. Antibodies that specifically recognize post-translationally modified proteins have a number of uses including immuno-cytochemistry and immuno-precipitation of the modified protein to purify protein-protein and protein-nucleic acid complexes. However, antibodies directed at modified sites on individual proteins are often non-specific. Here we describe a protocol to purify polyclonal antibodies that specifically detect the modified protein of interest. The approach uses iterative rounds of subtraction and affinity purification, using stringent washes to remove antibodies that recognize the unmodified protein and low sequence complexity epitopes containing the modified amino acid. Dot and western blots assays are employed to assess antibody preparation specificity. The approach is designed to overcome the common occurrence that a single round of subtraction and affinity purification is not sufficient to obtain a modified protein specific antibody preparation. One full round of antibody purification and specificity testing takes 6 days of discontinuous time. PMID:24457330
[Immunodetection of bacteriophages by a piezoelectric resonator with lateral electric field].
Gulii, O I; Zaitsev, B D; Shikhabudinov, A M; Teplykh, A A; Borodina, I A; Pavlii, S A; Larionova, O S; Fomin, A S; Staroverov, S A; Dykman, L A; Ignatov, O V
2016-01-01
It has been demonstrated that electroacoustic analysis with polyclonal antibodies can be used for bacteriophage detection. The frequency dependences of the real and imaginary parts of electrical impedance of a resonator with a viral suspension with antibodies were shown to be essentially different from the dependences of a resonator with control viral suspension without antibodies. It was shown that ΦAl-Sp59b bacteriophages were detected with the use of antibodies in the presence of foreign virus particles. The ΦAl-Sp59b bacteriophage content in the analyzed suspension was ~1010–106 phages/mL; the time of analysis was no more than 5 min. The optimally informative parameter for obtaining reliable information was the change in the real or imaginary part of electrical impedance at a fixed frequency near the resonance upon the addition of specific antibodies to the analyzed suspension. It was demonstrated that the interaction between bacteriophages and antibodies can be recorded, offering good prospects for the development of a biological sensor for liquid-phase identification and virus detection.
Myers, T J; Schat, K A; Mockett, A P
1989-01-01
Immunoglobulin class-specific enzyme-linked immunosorbent assays were developed for detecting antibodies against avian rotavirus in serum, intestinal contents, and bile from experimentally infected specific-pathogen-free (SPF) chickens. Both indirect and antibody-capture (AbC) assays were developed based on monoclonal antibodies specific for chicken IgG, IgM, and IgA. Treatment of purified rotavirus with sodium thiocyanate before coating the plate improved the rotavirus-specific reading in the indirect assay. Use of Immunolon 2 plates facilitated attachment of monoclonal antibodies to the plate in the AbC assay. Addition of 5% powdered skim milk to the diluent buffer reduced nonspecific background readings. The indirect assay was superior for detecting rotavirus-specific IgG, whereas the AbC assay was better for detecting rotavirus-specific IgM and IgA. The presence of intestinal contents in the assay wells did not reduce the measurable titers of IgG, IgM, or IgA. These assays showed that SPF chickens produced systemic and mucosal antibodies against avian rotavirus.
Liu, W; Wu, X; Wang, Z; Bao, J; Li, L; Zhao, Y; Li, J
2013-11-01
A field isolate of peste des petits ruminants virus (PPRV) from an outbreak in Tibet, China, was inoculated into goats to investigate the dynamics of virus excretion and antibody production. Further, animals received PPRV vaccine strain Nigeria 75/1. Ocular, nasal and oral samples were tested for the presence of virus antigen by one-step real-time qualitative RT-PCR (qRT-PCR); competitive ELISA (c-ELISA) was used for the measurement of specific antibodies against PPRV. Virus particles could be detected as early as day 3 post-inoculation (pi) and virus excretion lasted for up to day 26 pi. All four goats inoculated with the PPRV field isolate were seropositive as early as day 10 pi. In animals inoculated with the vaccine strain, antibody was detected at day 14 pi, and levels of neutralizing antibodies remained above the protection threshold level (1 : 8) for 8 months. Both virus particles and neutralizing antibodies were detected earlier in goats challenged with the field isolate than in those receiving the vaccine strain. © 2013 Blackwell Verlag GmbH.
Raj, G Dhinakar; Thiagarajan, V; Nachimuthu, K
2007-09-01
A simple, user-friendly, and rapid method to detect the presence of antibodies to egg drop syndrome 76 (EDS) virus in chicken sera based on an immunofiltration (flow-through) test was developed. Purified EDS virus antigen was coated onto nitrocellulose membranes housed in a plastic module with layers of absorbent filter pads underneath. Following addition of serum to be tested and washing, monoclonal antibodies or polyclonal serum to chicken immunoglobulin G (IgG) was used as a bridge antibody to mediate binding between EDS virus-specific IgG and protein A gold conjugate. The appearance of a pink dot indicated the presence of antibodies to EDS virus in the sample tested. The results could be obtained within 5-10 min. The developed immunofiltration test could detect antibodies in the sera of experimentally vaccinated chickens from 2 wk postvaccination. With field sera samples, this test was positive in samples having hemagglutination inhibition titers of 8 and above. This test has the potential to be used as a field-based kit to assess seroconversion in EDS-vaccinated flocks.
Rangel, H; Gatica, R; Ramos, C
1998-01-01
Surveys carried out in the Mexican state of Morelos indicate the presence of Chagas' disease. The aim of this work was to perform a pilot study to detect the presence of antibodies against Trypanosoma cruzi in donors from the Blood Bank at the Regional Hospital of Cuernavaca, Morelos. From March-September 1993, blood samples from 318 donors (284 men and 34 women) were collected. The of age range donors was from 18-45 years. Antibodies against T. cruzi were determined using a commercial ELISA kit. Fifty-four (17%) serum samples had antibodies against T. cruzi: 34 out of 284 men, and 20 out of 34 women were positive (11.9 and 58.8%, respectively). Of the 128 individuals who donated blood more than once, 9 (7%) were positive and had previously donated blood from 1-4 times. Antibodies against Leishmania sp. and T. rangeli were not determined. Based on the results of this study, procedures to detect antibodies against T. cruzi in blood donors and the application of a questionnaire inquiring into risk factors for T. cruzi infection should be implemented.
Yin, Ji Yong; Huo, Jun Sheng; Ma, Xin Xin; Sun, Jing; Huang, Jian
2017-12-01
To research a protein chip method which can simultaneously quantitative detect β-Lactoglobulin (β-L) and Lactoferrin (Lf) at one time. Protein chip printer was used to print both anti-β-L antibodies and anti-Lf antibodies on each block of protein chip. And then an improved sandwich detection method was applied while the other two detecting antibodies for the two antigens were added in the block after they were mixed. The detection conditions of the quantitative detection for simultaneous measurement of β-L and Lf with protein chip were optimized and evaluated. Based on these detected conditions, two standard curves of the two proteins were simultaneously established on one protein chip. Finally, the new detection method was evaluated by using the analysis of precision and accuracy. By comparison experiment, mouse monoclonal antibodies of the two antigens were chosen as the printing probe. The concentrations of β-L and Lf probes were 0.5 mg/mL and 0.5 mg/mL, respectively, while the titers of detection antibodies both of β-L and Lf were 1:2,000. Intra- and inter-assay variability was between 4.88% and 38.33% for all tests. The regression coefficients of protein chip comparing with ELISA for β-L and Lf were better than 0.734, and both of the two regression coefficients were statistically significant (r = 0.734, t = 2.644, P = 0.038; and r = 0.774, t = 2.998, P = 0.024). A protein chip method of simultaneously quantitative detection for β-L and Lf has been established and this method is worthy in further application. Copyright © 2017 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.
Love-Wave Sensors Combined with Microfluidics for Fast Detection of Biological Warfare Agents
Matatagui, Daniel; Fontecha, José Luis; Fernández, María Jesús; Gràcia, Isabel; Cané, Carles; Santos, José Pedro; Horrillo, María Carmen
2014-01-01
The following paper examines a time-efficient method for detecting biological warfare agents (BWAs). The method is based on a system of a Love-wave immunosensor combined with a microfluidic chip which detects BWA samples in a dynamic mode. In this way a continuous flow-through of the sample is created, promoting the reaction between antigen and antibody and allowing a fast detection of the BWAs. In order to prove this method, static and dynamic modes have been simulated and different concentrations of BWA simulants have been tested with two immunoreactions: phage M13 has been detected using the mouse monoclonal antibody anti-M13 (AM13), and the rabbit immunoglobulin (Rabbit IgG) has been detected using the polyclonal antibody goat anti-rabbit (GAR). Finally, different concentrations of each BWA simulants have been detected with a fast response time and a desirable level of discrimination among them has been achieved. PMID:25029282
Detection of antinuclear antibodies in SLE.
Kumar, Yashwant; Bhatia, Alka
2014-01-01
The antinuclear antibodies (ANA) also known as antinuclear factors (ANF) are unwanted molecules which bind and destroy certain structures within the nucleus. In systemic lupus erythematosus (SLE), they are produced in excess; hence their detection in the blood of patients is important for diagnosis and monitoring of the disease. Several methods are available which can be used to detect ANA; nevertheless, indirect immunofluorescence antinuclear antibody test (IF-ANA) is considered a "reference method" for their detection. Though IF-ANA is relatively easier to perform, its interpretation requires considerable skill and experience. The chapter therefore is aimed to provide comprehensive details to readers, not only about its methodology but also the result interpretation and reporting aspects of IF-ANA.
Yamada, Keiko; Wanchun, Jin; Ohkura, Teruko; Murai, Atsushi; Hayakawa, Reina; Kinoshita, Keiji; Mizutani, Makoto; Okamoto, Akira; Namikawa, Takao; Ohta, Michio
2013-01-01
Immunodetection of methicillin-resistant Staphylococcus aureus (MRSA) by conventional methods employing mammalian immunoglobulins has unknown detection limits, and often yields false-positive results because of the presence of S. aureus protein A, which binds the Fc region of mammalian IgG. In this study, a new PBP2a-specific chicken IgY antibody was developed in inbred and conventional chickens, and used for the detection of MRSA using whole cell lysate samples. Our results showed that this chicken IgY antibody minimized the side effects of protein A. Moreover, enzyme-linked immunosorbent assay and immunochromatography systems were used with a monoclonal and polyclonal anti-PBP2a IgY antibody, clearly differentiating MRSA from methicillin-sensitive S. aureus and other methicillin-sensitive Staphylococcus spp. The detection limit of the immunochromatography was 10(8) colony-forming units; therefore, 1 colony on an agar plate was adequate to distinguish MRSA from non-MRSA. The specificity and sensitivity of this assay were almost similar to that of a commercially available latex agglutination test; however, the procedure used in this study was less complicated. The entire detection procedure, including sample preparation, takes only 20 min and does not require special equipment. Therefore, the use of this IgY antibody as a new tool for the detection of MRSA is highly recommended.
LeBlanc, Amy K; Naik, Shruthi; Galyon, Gina D; Jenks, Nathan; Steele, Mike; Peng, Kah-Whye; Federspiel, Mark J; Donnell, Robert; Russell, Stephen J
2013-12-01
VSV-IFNβ-NIS is a novel recombinant oncolytic vesicular stomatitis virus (VSV) with documented efficacy and safety in preclinical murine models of cancer. To facilitate clinical translation of this promising oncolytic therapy in patients with disseminated cancer, we are utilizing a comparative oncology approach to gather data describing the safety and efficacy of systemic VSV-IFNβ-NIS administration in dogs with naturally occurring cancer. In support of this, we executed a dose-escalation study in purpose-bred dogs to determine the maximum tolerated dose (MTD) of systemic VSV-hIFNβ-NIS, characterize the adverse event profile, and describe routes and duration of viral shedding in healthy, immune-competent dogs. The data indicate that an intravenous dose of 10(10) TCID50 is well tolerated in dogs. Expected adverse events were mild to moderate fever, self-limiting nausea and vomiting, lymphopenia, and oral mucosal lesions. Unexpected adverse events included prolongation of partial thromboplastin time, development of bacterial urinary tract infection, and scrotal dermatitis, and in one dog receiving 10(11) TCID50 (10 × the MTD), the development of severe hepatotoxicity and symptoms of shock leading to euthanasia. Viral shedding data indicate that detectable viral genome in blood diminishes rapidly with anti-VSV neutralizing antibodies detectable in blood as early as day 5 postintravenous virus administration. While low levels of viral genome copies were detectable in plasma, urine, and buccal swabs of dogs treated at the MTD, no infectious virus was detectable in plasma, urine, or buccal swabs at any of the doses tested. These studies confirm that VSV can be safely administered systemically in dogs, justifying the use of oncolytic VSV as a novel therapy for the treatment of canine cancer.
An unexpected N-terminal loop in PD-1 dominates binding by nivolumab
Tan, Shuguang; Zhang, Hao; Chai, Yan; Song, Hao; Tong, Zhou; Wang, Qihui; Qi, Jianxun; Wong, Gary; Zhu, Xiaodong; Liu, William J.; Gao, Shan; Wang, Zhongfu; Shi, Yi; Yang, Fuquan; Gao, George F.; Yan, Jinghua
2017-01-01
Cancer immunotherapy by targeting of immune checkpoint molecules has been a research ‘hot-spot' in recent years. Nivolumab, a human monoclonal antibody targeting PD-1, has been widely used clinically since 2014. However, the binding mechanism of nivolumab to PD-1 has not yet been shown, despite a recent report describing the complex structure of pembrolizumab/PD-1. It has previously been speculated that PD-1 glycosylation is involved in nivolumab recognition. Here we report the complex structure of nivolumab with PD-1 and evaluate the effects of PD-1 N-glycosylation on the interactions with nivolumab. Structural and functional analyses unexpectedly reveal an N-terminal loop outside the IgV domain of PD-1. This loop is not involved in recognition of PD-L1 but dominates binding to nivolumab, whereas N-glycosylation is not involved in binding at all. Nivolumab binds to a completely different area than pembrolizumab. These results provide the basis for the design of future inhibitory molecules targeting PD-1. PMID:28165004
NASA Astrophysics Data System (ADS)
Tran, Quang Huy; Hanh Nguyen, Thi Hong; Mai, Anh Tuan; Thuy Nguyen, Thi; Khue Vu, Quang; Nga Phan, Thi
2012-03-01
This paper describes the development of electrochemical immunosensors based on human serum antibodies with different immobilization methods for detection of Japanese encephalitis virus (JEV). Human serum containing anti-JEV antibodies was used to immobilize onto the surface of silanized interdigitated electrodes by four methods: direct adsorption (APTES-serum), covalent binding with a cross linker of glutaraldehyde (APTES-GA-serum), covalent binding with a cross linker of glutaraldehyde combined with anti-human IgG (APTES-GA-anti-HIgG-serum) and covalent binding with a cross linker of glutaraldehyde combined with a bioaffinity of protein A (APTES-GA-PrA-serum). Atomic force microscopy was used to verify surface characteristics of the interdigitated electrodes before and after treatment with serum antibodies. The output signal of the immunosensors was measured by the change of conductivity resulting from the specific binding of JEV antigens and serum antibodies immobilized on the electrodes, with the help of horseradish peroxidase (HRP)-labeled secondary antibody against JEV. The results showed that the APTES-GA-PrA-serum method provided the highest signal of the electrochemical immunosensor for detection of JEV antigens, with the linear range from 25 ng ml-1 to 1 μg ml-1, and the limit of detection was about 10 ng ml-1. This study shows a potential development of novel electrochemical immunosensors applied for virus detection in clinical samples in case of possible outbreaks.
Bernard, Elyse D; Nguyen, Kathy C; DeRosa, Maria C; Tayabali, Azam F; Aranda-Rodriguez, Rocio
2017-01-01
Aptamers are short oligonucleotide sequences used in detection systems because of their high affinity binding to a variety of macromolecules. With the introduction of aptamers over 25 years ago came the exploration of their use in many different applications as a substitute for antibodies. Aptamers have several advantages; they are easy to synthesize, can bind to analytes for which it is difficult to obtain antibodies, and in some cases bind better than antibodies. As such, aptamer applications have significantly expanded as an adjunct to a variety of different immunoassay designs. The Multiple-Analyte Profiling (xMAP) technology developed by Luminex Corporation commonly uses antibodies for the detection of analytes in small sample volumes through the use of fluorescently coded microbeads. This technology permits the simultaneous detection of multiple analytes in each sample tested and hence could be applied in many research fields. Although little work has been performed adapting this technology for use with apatmers, optimizing aptamer-based xMAP assays would dramatically increase the versatility of analyte detection. We report herein on the development of an xMAP bead-based aptamer/antibody sandwich assay for a biomarker of inflammation (C-reactive protein or CRP). Protocols for the coupling of aptamers to xMAP beads, validation of coupling, and for an aptamer/antibody sandwich-type assay for CRP are detailed. The optimized conditions, protocols and findings described in this research could serve as a starting point for the development of new aptamer-based xMAP assays.
Influenza A virus H5-specific antibodies in mute swans (Cygnus olor) in the USA.
Kistler, Whitney M; Stallknecht, David E; Lebarbenchon, Camille; Pedersen, Kerri; Marks, David R; Mickley, Randy; DeLiberto, Thomas J; Yabsley, Michael J
2015-04-01
The use of serologic assays for influenza A virus (IAV) surveillance in wild birds has increased because of the availability of commercial enzyme-linked immunosorbent assays (ELISAs). Recently, an H5-specific blocking ELISA (bELISA) was shown to reliably detect H5-specific antibodies to low- and high-pathogenic H5 viruses in experimentally infected waterfowl. Mute Swans (Cygnus olor) were frequently associated with highly pathogenic H5N1 outbreaks in Europe and may have a similar role if highly pathogenic H5N1 is introduced into North America. We measured the prevalence of antibodies to the nucleoprotein and H5 protein in Mute Swans using three serologic assays. We collected 340 serum samples from Mute Swans in Michigan, New Jersey, New York, and Rhode Island, US. We detected antibodies to the IAV nucleoprotein in 66.2% (225/340) of the samples. We detected H5-specific antibodies in 62.9% (214/340) and 18.8% (64/340) using a modified H5 bELISA protocol and hemagglutination inhibition (HI) assay, respectively. The modified H5 bELISA protocol detected significantly more positive samples than did the manufacturer's protocol. We also tested 46 samples using virus neutralization. Neutralization results had high agreement with the modified H5 bELISA protocol and detected a higher prevalence than did the HI assay. These results indicate that North American Mute Swans have high nucleoprotein and H5 antibody prevalences.
Lebani, Kebaneilwe; Jones, Martina L; Watterson, Daniel; Ranzoni, Andrea; Traves, Renee J; Young, Paul R; Mahler, Stephen M
2017-01-01
The multidimensional nature of dengue virus (DENV) infections, which can be caused by four distinct serotypes of the virus, complicates the sensitivity of assays designed for the diagnosis of infection. Different viral markers can be optimally detected at different stages of infection. Of particular clinical importance is the early identification of infection, which is pivotal for disease management and the development of blood screening assays. Non-structural protein 1 (NS1) is an early surrogate marker of infection and its detection in serum coincides with detectable viraemia. The aim of this work was to isolate and characterise serotype-specific monoclonal antibodies that bind to NS1 for each of the four DENV serotypes. This was achieved using phage display and a subtractive biopanning strategy to direct the antibody selection towards serotype-specific epitopes. This antibody isolation strategy has advantages over immunisation techniques where it is difficult to avoid antibody responses to cross-reactive, immunodominant epitopes. Serotype specificity to recombinant antigen for each of the antibodies was confirmed by Enzyme Linked Immunosorbent Assay (ELISA) and Surface Plasmon Resonance. Confirmation of binding to native DENV NS1 was achieved using ELISA and immunofluorescence assay on DENV infected Vero cells. No cross-reactivity with Zika or Kunjin viruses was observed. A previously isolated pan-reactive antibody that binds to an immunodominant epitope was able to pair with each of the serotype-specific antibodies in a sandwich ELISA, indicating that the serotype specific antibodies bind to epitopes which are all spatially distinct from the immunodominant epitope. These antibodies were suitable for use in a multiplexed assay for simultaneous detection and serotyping of DENV NS1 in human serum. This work demonstrates that phage display coupled with novel biopanning strategies is a valuable in vitro methodology for isolation of binders that can discern amongst antigens with high homology for diagnostic applicability.
Monoclonal antibodies to synthetic pyrethroids and method for detecting the same
Stanker, Larry H.; Vanderlaan, Martin; Watkins, Bruce E.; Van Emon, Jeanette M.; Bigbee, Carolyn L.
1992-01-01
Methods are described for making specific monoclonal antibodies which may be used in a sensitive immunoassay for detection of synthetic pyrethroids in foods and environmental samples. Appropriate sample preparation and enzyme amplification of the immunoassay for this widely-used class of pesticides permits detection at low levels in laboratory and field tested samples.
Monoclonal antibodies to synthetic pyrethroids and method for detecting the same
Stanker, L.H.; Vanderlaan, M.; Watkins, B.E.; Van Emon, J.M.; Bigbee, C.L.
1992-04-28
Methods are described for making specific monoclonal antibodies which may be used in a sensitive immunoassay for detection of synthetic pyrethroids in foods and environmental samples. Appropriate sample preparation and enzyme amplification of the immunoassay for this widely-used class of pesticides permits detection at low levels in laboratory and field tested samples. 6 figs.
Detection of bacterial-reactive natural IgM antibodies in desert bighorn sheep populations
Palmer, Amy L.; Zielke, Ryszard A.; Sikora, Aleksandra E.; Beechler, Brianna R.; Jolles, Anna E.; Epps, Clinton W.
2017-01-01
Ecoimmunology is a burgeoning field of ecology which studies immune responses in wildlife by utilizing general immune assays such as the detection of natural antibody. Unlike adaptive antibodies, natural antibodies are important in innate immune responses and often recognized conserved epitopes present in pathogens. Here, we describe a procedure for measuring natural antibodies reactive to bacterial antigens that may be applicable to a variety of organisms. IgM from desert bighorn sheep plasma samples was tested for reactivity to outer membrane proteins from Vibrio coralliilyticus, a marine bacterium to which sheep would have not been exposed. Immunoblotting demonstrated bighorn sheep IgM could bind to a variety of bacterial cell envelope proteins while ELISA analysis allowed for rapid determination of natural antibody levels in hundreds of individual animals. Natural antibody levels were correlated with the ability of plasma to kill laboratory strains of E. coli bacteria. Finally, we demonstrate that natural antibody levels varied in two distinct populations of desert bighorn sheep. These data demonstrate a novel and specific measure of natural antibody function and show that this varies in ecologically relevant ways. PMID:28662203
Sierralta, W D; Thole, H H
1996-05-01
The unmasking of estradiol receptor in paraffin sections of Bouin's-fixed uterine tissue from ovariectomized gilts was attained with microwave treatment. Immunocytochemistry of the receptor was performed using a polyclonal or five monoclonal antibodies, two of which are commercially available, reacting with different domains of the protein and an amplified-peroxidase system for detection. With five of the antibodies, a predominance of nuclear staining was observed in cells of endometrial glands, while one monoclonal antibody (13H2), reacting with the receptor's domain E, showed a preference for the cytoplasmic receptor. In stroma, all antibodies detected more receptor in nuclei than in cytoplasm. In epithelium, the commercially available antibody H222, our monoclonals 13H2 and HT65, and the polyclonal antibody 402 demonstrated more receptor in cytoplasmic than in nuclear areas. In myometrium, the nuclei from longitudinal and ring muscles were definitely stained with the antibodies. We conclude that the accessibilities of the antibody epitopes of the receptor differ according to the functional uterine cell type.
NASA Astrophysics Data System (ADS)
Cişmileanu, Ana; Sima, Cornelia; Grigoriu, Constantin
2007-08-01
A quantum dot - immunoglobulin conjugate specific for pig IgG, was obtained by carbodiimide chemistry. We used a Western blot technique for detecting specific antibodies against Actinobacillus pleuropneumoniae (A. pp), which cause porcine pleuropneumonia. The antigen used in this technique was Apx haemolysin which is an important virulence factor of A. pp and it induces protective immunity in vaccined pigs. The detection on Western blot membrane was possible at 1/50 dilution of quantum dot conjugate at a dilution of pig serum till 1/6400. The results for pig serum demonstrated a higher sensitivity of QD-based Western blot technique for the presence of antibodies specific for Apx haemolysin in comparison with similar classical techniques (with coloured substrate for enzyme present in secondary antibody conjugate).
Toxin detection using a fiber-optic-based biosensor
NASA Astrophysics Data System (ADS)
Ogert, Robert A.; Shriver-Lake, Lisa C.; Ligler, Frances S.
1993-05-01
Using an evanescent wave fiber optic-based biosensor developed at Naval Research Laboratory, ricin toxin can be detected in the low ng/ml range. Sensitivity was established at 1 - 5 ng/ml using a two-step assay. The two-step assay showed enhanced signal levels in comparison to a one-step assay. A two-step assay utilizes a 10 minute incubation of an immobilized affinity purified anti-ricin antibody fiber optic probe in the ricin sample before placement in a solution of fluorophore-labeled goat anti-ricin antibodies. The specific fluorescent signal is obtained by the binding of the fluorophore-labeled antibodies to ricin which is bound by the immobilized antibodies on the fiber optic probe. The toxin can be detected directly from urine and river water using this fiber optic assay.
[Value of using polyethylene glycol in the indirect antiglobulin test with erythrocytes].
Michalewska, B; Walewska, I; Seyfriedowa, H; Kuśnierz-Alejska, G
1991-01-01
A series of comparative investigations was carried out for establishing the value of the indirect antiglobulin test (IAT) in its first phase. The results showed that PEG, in relation to NaCl solution of low ionic strength, increased the reactivity of various antibodies of different specificity present in 72 studied sera. A significant superiority of IAT-PEG to IAT-BISS was noted in 45.8% of these sera. In search for antibodies in sera of 1160 patients IAT-PEG detected 7 antibodies not reacting in the IAT-LISS, and 5 of them had Rh system specificity, one was anti-K and one anti-Jka. Although the IAT-PEG was more sensitive than IAT-LISS in the detection of anti-Rh antibodies, it was less sensitive in this range than the enzymatic LEN test with which not only 5 of these antibodies were demonstrated but which detected also 8 antibodies not demonstrated in IAT-PEG or IAT-LISS. All 5 antibodies not detected by the IAT-PEG but demonstrated in the IAT-LISS were specific for the Lewis system. The per cent of reactions regarded as non-specific in the IAT-PEG was 1.3%. The IAT-PEG modification may be recommended as a sensitive, simple and specific method extending the possibilities of immunohematological diagnosis, especially in cases of post-transfusion reactions and in difficulties of interpretation connected with the occurrence of weakly positive reactions in the IAT-LISS.
Thyroid disorders and the prevalence of antithyroid antibodies in Shiraz population.
Karimi, Fariba; Kalantarhormozi, Mohammad Reza; Dabbaghmanesh, Mohammad Hossein; Ranjbar Omrani, Gholamhossein
2014-05-01
Thyroid dysfunction is a common health problem affecting millions of patients worldwide. Autoimmune thyroid disorders are among the most common autoimmune disorders. In this population-based study, we assessed the prevalence of abnormal thyroid function, antithyroid antibodies and the probable relationship between them in Shiraz, southern Iran. Serum thyrotropin (TSH) was determined in 981 subjects (66.8% female and 33.2% male; mean age: 39.1 ± 14.3 years), who were selected with stratified random sampling. Because of the preponderance of females over males, we performed the statistical analyses using sex-weighted data (50% for each sex). Also, antithyroid peroxidase antibodies (TPOAb), and antithyroglobulin antibodies (TgAb) were measured in two random subgroups of 376 and 537 patients respectively). Thyromegaly detected on physical examination. In this cross-sectional study, 8.1% of participants had elevated serum TSH level and 3.4% had low serum TSH level. A statistically significant relationship was found between gender and thyromegaly and TSH values. Positive TPOAb and positive TgAb were detected in 17% and 5.1% of participants respectively. In addition, a significant relationship was observed between elevated TSH levels and positive results for both antibodies. Detectable levels of thyroid antibodies correlated with female sex, while no correlation was observed between detectable levels of thyroid antibodies and thyromegaly. Thyroid disorders, especially elevated TSH level, are common. It seems that autoimmune mechanisms are strongly involved in the etiology of hypothyroidism in this area.
Ma, Xiaoyue; Niezgoda, Michael; Blanton, Jesse D; Recuenco, Sergio; Rupprecht, Charles E
2012-08-03
Two major techniques are currently used to estimate rabies virus antibody values: neutralization assays, such as the rapid fluorescent focus inhibition test (RFFIT), and enzyme-linked immunosorbent assays (ELISAs). The RFFIT is considered the gold standard assay and has been used to assess the titer of rabies virus neutralizing antibodies for more than three decades. In the late 1970s, ELISA began to be used to estimate the level of rabies virus antibody and has recently been used by some laboratories as an alternate screening test for animal sera. Although the ELISA appears simpler, safer and more efficient, the assay is less sensitive in detecting low values of rabies virus neutralizing antibodies than neutralization tests. This study was designed to evaluate a new ELISA-based method for detecting rabies virus binding antibody. This new technique uses electro-chemi-luminescence labels and carbon electrode plates to detect binding events. In this comparative study, the RFFIT and the new ELISA-based technique were used to evaluate the level of rabies virus antibodies in human and animal serum samples. By using a conservative approximation of 0.15 IU/ml as a cutoff point, the new ELISA-based technique demonstrated a sensitivity of 100% and a specificity of 95% for human samples and for experimental animal samples. The sensitivity and specificity for field animal samples was 96% and 95%, respectively. The preliminary results from this study appear promising and demonstrate a higher sensitivity than traditional ELISA methods. Published by Elsevier Ltd.
Schvartz, Gili; Epp, Tasha; Burgess, Hilary J; Chilton, Neil B; Lohmann, Katharina L
2015-07-01
To investigate the agreement between available serologic tests for the detection of antibodies against Anaplasma phagocytophilum and Borrelia burgdorferi, 50 serum samples from horses of unknown clinical status and at low risk for infection were tested. In addition to a point-of-care enzyme-linked immunosorbent assay (pocELISA), the evaluated tests included 2 indirect fluorescent antibody tests (IFATs) for antibodies against A. phagocytophilum and an IFAT, an ELISA confirmed with Western blot, and the Lyme multiplex assay for antibodies against B. burgdorferi. For each pair-wise comparison between serologic tests, the difference in the proportion of seropositive results as well as kappa and the prevalence-adjusted, bias-adjusted kappa were calculated. The proportion of seropositive results differed significantly in each pairwise comparison of tests for detection of antibodies against A. phagocytophilum, and between the pocELISA and IFAT as well as between the pocELISA and Lyme multiplex assay for detection of antibodies against B. burgdorferi. Agreement based on kappa varied from poor to fair while agreement was improved when evaluating prevalence-adjusted, bias-adjusted kappa. Lack of agreement may be explained by differences in methodology between the evaluated tests, cross-reactivity or false-positive and false-negative tests. In addition to the limitations of serologic test interpretation in the absence of clinical disease, this data suggest that screening of horses for exposure to tick-borne diseases in nonendemic areas may not be warranted. © 2015 The Author(s).
Autoantibodies other than Anti-desmogleins in Pemphigus Vulgaris Patients
Saleh, Marwah Adly; Salem, Hedayat; El Azizy, Hoda
2017-01-01
Background: Pemphigus vulgaris (PV) is an immunoglobulin G-mediated autoimmune bullous skin disease. Nonorgan-specific antibodies were detected in Tunisian and Brazilian pemphigus patients with different prevalence. Materials and Methods: Fifty PV patients and fifty controls were screened for antinuclear antibodies (ANAs), anti-smooth muscle antibodies (ASMAs), anti-parietal antibodies (APAs), anti-mitochondrial antibodies, and Anti-nuclear cytoplasmic antibodies (ANCA) by indirect immunofluorescence. Results: Thirty-nine patients were female and 11 were male. Fifteen patients did not receive treatment before while 35 patients were on systemic steroid treatment ± azathioprine. Twenty (40%) of the PV patients and 1 (2%) control had positive ANA. ANA was significantly higher in PV patients than controls, P < 0.0001. ASMAs were detected in 20 (40%) PV patients and none of the controls. ASMA was significantly higher in PV patients than controls, P < 0.0001. No significant difference was detected between treated and untreated regarding ANA, P - 0.11. However, there was a significant difference between treated and untreated regarding ASMA, P - 0.03. Six patients (12%) and none of the controls had positive APA. There was a significant difference between the patients and the controls in APA. P - 0.027. Conclusion: Egyptian PV patients showed more prevalent ANA, ASMA, and APA than normal controls. Follow-up of those patients is essential to detect the early development of concomitant autoimmune disease. Environmental factors might account for the variability of the nonorgan-specific antibodies among different populations. PMID:28216725
Mori, Akihiro; Ojima-Kato, Teruyo; Fuchi, Shingo; Kaiya, Shinichi; Kojima, Takaaki; Nakano, Hideo
2017-12-01
In this report, we developed a rapid immunoassay system, designated the bioluminescent interference gathering optical (BINGO) assay, which required no time-consuming washing steps for removal of unbound antibodies. This system employed a luciferase (Luc)-conjugated antibody (LucAb) and a dye that absorbed light from the LucAb. The antigen-associated LucAb was localized by transfer of an antigen to the detector-side of a chamber where a detector photomultiplier tube (PMT) was installed. In contrast, the free LucAb was distributed throughout the solution, and the light emitted by the free LucAb was absorbed by the dye. Therefore, only light from LucAb associated with antigen could be detected by the PMT. The new system could be used to rapidly detect the amount of antigen-antibody-Luc complex by collecting steps, such as centrifugation or magnetic collection of antibody-coated magnetic beads. Proof-of-principle experiments were performed using a model system with streptavidin beads and biotinylated Luc. The feasibility of the system was demonstrated using magnetic beads coated with anti-Escherichia coli O157 antibody, enabling detection of 4 × 10 3 cells in only 15 min. Thus, this system may have applications in a variety of biomedical fields. Copyright © 2017 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.
Monoclonal antibody technologies and rapid detection assays
USDA-ARS?s Scientific Manuscript database
Novel methodologies and screening strategies will be outlined on the use of hybridoma technology for the selection of antigen specific monoclonal antibodies. The development of immunoassays used for diagnostic detection of prions and bacterial toxins will be discussed and examples provided demonstr...
Xu, L; Wang, P; Chen, S
1994-06-01
Using TAT and ELISA, 50 samples of pleural effusion and sera from patients infected with non-Legionella pneumophila were detected for antibodies against Legionella pneumophila serogroups 1 and 6, respectively. The average titre and upper limit value (99%, mean + 2.326S) calculated. In addition, a pleural effusion and a serum from a patient with Legionnaire's pneumonia were also detected by TAT and ELISA. The result showed that the titre of this antibody in his pleural effusion was not only over the upper limit, but also higher than that in his serum.
Harris, C C; Vahakangas, K; Newman, M J; Trivers, G E; Shamsuddin, A; Sinopoli, N; Mann, D L; Wright, W E
1985-01-01
Coke oven workers are exposed to high levels of carcinogenic polycyclic aromatic hydrocarbons, including benzo[a]pyrene (B[a]P), and are at increased risk of lung cancer. Since B[a]P is enzymatically activated to 7 beta,8 alpha-dihydroxy(9 alpha, 10 alpha)epoxy-7,8,9,10-tetrahydrobenzo[a]pyrene (B[a]PDE) that forms adducts with DNA, the presence of these adducts was measured in DNA from peripheral blood lymphocytes by synchronous fluorescence spectrophotometry and enzyme radioimmunoassay. Approximately two-thirds of the workers had detectable levels of B[a]PDE-DNA adducts. Antibodies to the DNA adducts were also found in the serum of 27% of the workers. B[a]PDE-DNA adducts were not detectable in lymphocytes and antibodies to the adducts were not detected in sera from a control group of nonsmoking laboratory workers. DNA adducts and/or antibodies to the adducts indicate exposure to B[a]P and its metabolic activation to the carcinogenic metabolite that covalently binds to and damages DNA. Detection of adducts and antibodies to them may also be useful as internal dosimeters of the pathobiological effective doses of chemical carcinogens. PMID:2413443
Detection of ricin in food using electrochemiluminescence-based technology.
Garber, Eric A E; O'Brien, Thomas W
2008-01-01
Ricin is a toxic ribosome inactivating protein (RIP-II) present in beans of the castor plant, Ricinus communis. Its potential as a biodefense threat has made the rapid, sensitive detection of ricin in food important to the U.S. Food and Drug Administration. Samples of juice, dairy products, soda, vegetables, bakery products, chocolate, and condiments were spiked with varying concentrations of ricin and analyzed using a 96-well format, electrochemiluminescence (ECL) immunoassay. Assay configurations included the use of a monoclonal capture antibody coupled with either a polyclonal or monoclonal detector antibody. The samples and detector antibodies were either added sequentially or in combination during the capture step. Using the polyclonal antibody, 0.04 ng/mL ricin was detected in analytical samples prepared from several beverages. By simultaneously incubating the sample with detector antibody, it was possible to decrease the assay time to a single 20 min incubation step with a limit of detection <10 ng/mL. Assays run according to this single incubation step exhibited a hook effect (decrease in signal at high concentrations of ricin), but because of the large signal-to-noise ratio associated with the ECL assay, the response remained above background and detectable. Thus, the ECL assay was uniquely suited for the screening of samples for ricin.
Wang, Jianhao; Qin, Yuqin; Qin, Haifang; Liu, Li; Ding, Shumin; Teng, Yiwan; Ji, Junling; Qiu, Lin; Jiang, Pengju
2016-08-01
Herein, we have developed an in-capillary assay for simultaneous detection of the assembly and disassembly of the multivalent HA tag peptide and antibody. HA tag with hexahistidine at C terminus (YPYDVPDYAG4 H6 , termed YPYDH6 ) was conjugated with quantum dots (QDs) by metal-affinity force to form a multivalent HA tag (QD-YPYDH6 ). QD-YPYDH6 and monoclonal anti-HA antibody (anti-HA) were sequentially injected into the capillary. They were mixed and assembled inside the capillary. The reaction products were online discriminated and detected by fluorescence coupled capillary electrophoresis (CE-FL). For the in-capillary assay, the binding efficiency of the multivalent HA tag and antibody on was influenced by the molar ratio and injection time. Such novel assay could even give out the self-assembly kinetic constant of QDs and YPYDH6 as KD of 34.1 μM with n (binding cooperativeness) of 2.2 by Hill equation. More importantly, the simultaneous detection of the assembly and imidazole (Im) induced disassembly of the QD-YPYDH6 -anti-HA complex was achieved in a single in-capillary assay. Our study demonstrated a new method for the online detection of antigen-antibody interactions. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Tan, Weiming; Huang, Yuan; Nan, Tiegui; Xue, Changguo; Li, Zhaohu; Zhang, Qingchuan; Wang, Baomin
2010-01-15
Development of microcantilever biosensors for small molecules was exemplified with the beta-adrenergic agonist clenbuterol and the antibiotic chloramphenicol. In this paper, antibody sulfhydrylation and protein A were used to modify the microcantilever Au surface, and the antibody activities on the microcantilever were evaluated with direct competitive enzyme-linked immunosorbent assay (dcELISA). The activity of the antibodies immobilized on the microcantilever via protein A was 1.7-fold of that via the sulfhydrylation reagent 2-iminothiolane hydrochloride. A microcantilever immunosensor method with protein A as the functionalization reagent was established to detect the residues of clenbuterol and chloramphenicol at limits of detection (LOD) of approximately 0.1 and 0.2 ng/mL, respectively. Such LODs were better than that of the corresponding dcELISAs. The concentration of clenbuterol in a fortified feed sample detected with the microcantilever immunosensor after thorough extraction and purification agreed well with that detected with the dcELISA. Protein A showed to be simple and reproducible for functionalization of the antibodies on the Au surface and, thus, has common application values in microcantilever immunosensor development. The results suggest that microcantilever immunosensors be suitable for detection of small molecules, and the assay sensitivity is mainly related to the quality and activities of the antibodies.
Human Anti-Lipopolysaccharid (LPS) antibodies against Legionella with high species specificity.
Kuhn, Philipp; Thiem, Stefanie; Steinert, Michael; Purvis, Duncan; Lugmayr, Veronika; Treutlein, Ulrich; Plobner, Lutz; Leiser, Robert-Matthias; Hust, Michael; Dübel, Stefan
2017-07-19
Legionella are Gram-negative bacteria that are ubiquitously present in natural and man-made water reservoirs. When humans inhale aerosolized water contaminated with Legionella, alveolar macrophages can be infected, which may lead to a life-threatening pneumonia called Legionnaires' disease. Due to the universal distribution of Legionella in water and their potential threat to human health, the Legionella concentration in water for human use must be strictly monitored, which is difficult since the standard detection still relies on lengthy cultivation and analysis of bacterial morphology. In this study, an antibody against L. pneumophila has been generated from the naïve human HAL antibody libraries by phage-display for the first time. The panning was performed on whole bacterial cells in order to select antibodies that bind specifically to the cell surface of untreated Legionella. The bacterial cell wall component lipopolysaccharide (LPS) was identified as the target structure. Specific binding to the important pathogenic L. pneumophila strains Corby, Philadelphia-1 and Knoxville was observed, while no binding was detected to seven members of the families Enterobacteriaceae, Pseudomonadaceae or Clostridiaceae. Production of this antibody in the recombinant scFv-Fc format using either a murine or a human Fc part allowed the set-up of a sandwich-ELISA for detection of Legionella cells. The scFv-Fc construct proved to be very stable, even when stored for several weeks at elevated temperatures. A sensitivity limit of 4,000 cells was achieved. The scFv-Fc antibody pair was integrated on a biosensor, demonstrating the specific and fast detection of L. pneumophila on a portable device. With this system, 10,000 Legionella cells were detected within 35 min. Combined with a water filtration/concentration system, this antibody may be developed into a promising reagent for rapid on-site Legionella monitoring.
Tait, Brian D.
2016-01-01
This review outlines the development of human leukocyte antigen (HLA) antibody detection assays and their use in organ transplantation in both antibody screening and crossmatching. The development of sensitive solid phase assays such as the enzyme-linked immunosorbent assay technique, and in particular the bead-based technology has revolutionized this field over the last 10–15 years. This revolution however has created a new paradigm in clinical decision making with respect to the detection of low level pretransplant HLA sensitization and its clinical relevance. The relative sensitivities of the assays used are discussed and the relevance of conflicting inter-assay results. Each assay has its advantages and disadvantages and these are discussed. Over the last decade, the bead-based assay utilizing the Luminex® fluorocytometer instrument has become established as the “gold standard” for HLA antibody testing. However, there are still unresolved issues surrounding this technique, such as the presence of denatured HLA molecules on the beads which reveal cryptic epitopes and the issue of appropriate fluorescence cut off values for positivity. The assay has been modified to detect complement binding (CB) in addition to non-complement binding (NCB) HLA antibodies although the clinical relevance of the CB and NCB IgG isotypes is not fully resolved. The increase sensitivity of the Luminex® bead assay over the complement-dependent cytotoxicity crossmatch has permitted the concept of the “virtual crossmatch” whereby the crossmatch is predicted to a high degree of accuracy based on the HLA antibody specificities detected by the solid phase assay. Dialog between clinicians and laboratory staff on an individual patient basis is essential for correct clinical decision making based on HLA antibody results obtained by the various techniques. PMID:28018342
Adaptive virus detection using filament-coupled antibodies.
Stone, Gregory P; Lin, Kelvin S; Haselton, Frederick R
2006-01-01
We recently reported the development of a filament-antibody recognition assay (FARA), in which the presence of virions in solution initiates the formation of enzyme-linked immunosorbent assay (ELISA)-like antibody complexes. The unique features of this assay are that processing is achieved by motion of a filament and that, in the presence of a virus, antibody-virus complexes are coupled to the filament at known locations. In this work, we combine the unique features of this assay with a 638-nm laser-based optical detector to enable adaptive control of virus detection. Integration of on-line fluorescence detection yields approximately a five-fold increase in signal-to-noise ratio (SNR) compared to the fluorescence detection method reported previously. A one-minute incubation with an M13K07 test virus is required to detect 10(10) virionsml, and 40 min was required to detect 10(8) virionsml. In tests of the components of an adaptive strategy, a 30-min virus (3.3 x 10(10) virionsml) incubation time, followed by repositioning the filament-captured virus either within the detecting antibody chamber, (20 microg ml) or within the virus chamber, found an increase in signal roughly proportional to the cumulative residence times in these chambers. Furthermore, cumulative fluorescence signals observed for a filament-captured virus after repeated positioning of the filament within the virus chamber are similar to those observed for a single long incubation time. The unique features of the FARA-like design combined with online optical detection to direct subsequent bioprocessing steps provides new flexibility for developing adaptive molecular recognition assays.
Wood, Britta A; Carver, Scott; Troyer, Ryan M; Elder, John H; VandeWoude, Sue
2013-10-31
Microsphere immunoassays (MIAs) allow rapid and accurate evaluation of multiple analytes simultaneously within a biological sample. Here we describe the development and validation of domestic cat-specific MIAs for a) the quantification of total IgG and IgA levels in plasma, and b) the detection of IgG and IgA antibodies to feline immunodeficiency virus (FIV) capsid (CA) and surface (SU) proteins, and feline CD134 in plasma. These assays were used to examine the temporal antibody response of domestic cats infected with apathogenic and pathogenic FIVs, and domestic cats infected with parental and chimeric FIVs of varying pathogenicity. The results from these studies demonstrated that a) total IgG antibodies increase over time after infection; b) α-CA and α-SU IgG antibodies are detectable between 9 and 28 days post-infection and increase over time, and these antibodies combined represent a fraction (1.8 to 21.8%) of the total IgG increase due to infection; c) measurable α-CD134 IgG antibody levels vary among individuals and over time, and are not strongly correlated with viral load; d) circulating IgA antibodies, in general, do not increase during the early stage of infection; and e) total IgG, and α-CA and α-SU IgG antibody kinetics and levels vary with FIV viral strain/pathogenicity. The MIAs described here could be used to screen domestic cats for FIV infection, and to evaluate the FIV-specific or total antibody response elicited by various FIV strains/other diseases. © 2013.
Ricciuti, Adriana; De Remigis, Alessandra; Landek-Salgado, Melissa A.; De Vincentiis, Ludovica; Guaraldi, Federica; Lupi, Isabella; Iwama, Shintaro; Wand, Gary S.; Salvatori, Roberto
2014-01-01
Context: Pituitary antibodies have been measured mainly to identify patients whose disease is caused or sustained by pituitary-specific autoimmunity. Although reported in over 100 publications, they have yielded variable results and are thus considered of limited clinical utility. Objectives: Our objectives were to analyze all publications reporting pituitary antibodies by immunofluorescence for detecting the major sources of variability, to experimentally test these sources and devise an optimized immunofluorescence protocol, and to assess prevalence and significance of pituitary antibodies in patients with pituitary diseases. Study Design and Outcome Measures: We first evaluated the effect of pituitary gland species, section fixation, autofluorescence quenching, blockade of unwanted antibody binding, and use of purified IgG on the performance of this antibody assay. We then measured cross-sectionally the prevalence of pituitary antibodies in 390 pituitary cases and 60 healthy controls, expressing results as present or absent and according to the (granular, diffuse, perinuclear, or mixed) staining pattern. Results: Human pituitary was the best substrate to detect pituitary antibodies and yielded an optimal signal-to-noise ratio when treated with Sudan black B to reduce autofluorescence. Pituitary antibodies were more common in cases (95 of 390, 24%) than controls (3 of 60, 5%, P = .001) but did not discriminate among pituitary diseases when reported dichotomously. However, when expressed according to their cytosolic staining, a granular pattern was highly predictive of pituitary autoimmunity (P < .0001). Conclusion: We report a comprehensive study of pituitary antibodies by immunofluorescence and provide a method and an interpretation scheme that should be useful for identifying and monitoring patients with pituitary autoimmunity. PMID:24606106
Wood, Britta A.; Carver, Scott; Troyer, Ryan M.; Elder, John H.; VandeWoude, Sue
2013-01-01
Microsphere immunoassays (MIAs) allow rapid and accurate evaluation of multiple analytes simultaneously within a biological sample. Here we describe the development and validation of domestic cat-specific MIAs for a) the quantification of total IgG and IgA levels in plasma, and b) the detection of IgG and IgA antibodies to feline immunodeficiency virus (FIV) capsid (CA) and surface (SU) proteins, and feline CD134 in plasma. These assays were used to examine the temporal antibody response of domestic cats infected with apathogenic and pathogenic FIVs, and domestic cats infected with parental and chimeric FIVs of varying pathogenicity. The results from these studies demonstrated that a) total IgG antibodies increase over time after infection; b) α-CA and α-SU IgG antibodies are detectable between 9–28 days post-infection and increase over time, and these antibodies combined represent a fraction (1.8 to 21.8%) of the total IgG increase due to infection; c) measurable α-CD134 IgG antibody levels vary among individuals and over time, and are not strongly correlated with viral load; d) circulating IgA antibodies, in general, do not increase during the early stage of infection; and e) total IgG, and α-CA and α-SU IgG antibody kinetics and levels vary with FIV viral strain/pathogenicity. The MIAs described here could be used to screen domestic cats for FIV infection, and to evaluate the FIV-specific or total antibody response elicited by various FIV strains/other diseases. PMID:23954271
Hatakeyama, Naoki; Hori, Tsukasa; Yamamoto, Masaki; Inazawa, Natsuko; Iesato, Kotoe; Miyazaki, Toru; Ikeda, Hisami; Tsutsumi, Hiroyuki; Suzuki, Nobuhiro
2011-12-01
PTR is a serious problem in patients being treated for hematologic disorders. Two patients with acute leukemia developed PTR after allogeneic BMT from one HLA-antigen-mismatched mother attributable to HLA antibodies, which could not be detected in their serum before BMT. HLA antibodies, whose specificity resembled that of each patient, were detected in each donor's serum. Each donor had probably been immunized during pregnancy by their partner's HLA antigens expressed by the fetus, consequently, transplanted donor-derived cells provoked HLA antibodies in each recipient early after BMT, and those HLA antibodies induced PTR. If the mothers are selected as donors for their children, they should be tested for the presence of HLA antibodies. © 2010 John Wiley & Sons A/S.
Immunochemical detection of food-derived isothiocyanate as a lysine conjugate.
Nakamura, Toshiyuki; Kitamoto, Noritoshi; Osawa, Toshihiko; Kato, Yoji
2010-01-01
In a previous study we prepared monoclonal antibody against allyl isothiocyanate (AITC)-modified lysine (Lys), and found that AITC reacted with Lys under physiological conditions in vitro (T. Nakamura et al., Chem. Res. Toxicol., 22, 536-542 (2009)). In the present study, antibodies against benzyl isothiocyanate (ITC), 6-methylsulfinylhexyl ITC and phenethyl ITC modified protein were prepared, and the respective monoclonal antibodies, B6C9, 6MS3D10, and PE3A10 were obtained. These antibodies were applied to ITC detection in food using shredded Wasabia japonica (wasabi) and ground Carica papaya (papaya) seed by trapping ITC with biotin-labeled bovine serum albumin. ITC formation from the wasabi and papaya seed samples was confirmed using the antibodies in a dose-dependent manner. These antibodies might be applicable in identifying food-derived ITC.
Karol, M H; Hauth, B A
1982-01-01
Hypersensitivity to hexamethylene diisocyanate (HDI) has been reported following occupational exposure. Diagnosis of sensitivity is usually made from clinical evaluation of symptomatology. An in vitro serologic assay for HDI sensitivity was developed by immunizing guinea pigs with HDI and with hexyl isocyanate (HMI). Animals injected intradermally with HMI produced hapten-specific antibodies whereas guinea pigs injected with HDI produced antibodies specific for larger determinants which included the HDI hapten. The larger determinants were assumed to be composed of portions of "self" molecules which reacted in vivo with HDI. Serum albumin appeared to be one such molecule. No cross reactions were noted between antibodies to HDI and another widely used industrial isocyanate, toluene diisocyanate (TDI). Antigens effective in detecting antibodies to HDI or HMI were tested for ability to detect reaginic antibodies in a worker with clinical "HDI" asthma. Using a radioimmunoassay (RAST), antibodies reacted with conjugates containing either HDI or HMI as haptens. In addition, the prevalance of HDI polyisocyanates (Desmodur N) in spray paints prompted its use as a hapten. Antibodies reacted with Desmodur N antigen conjugates in RAST. RAST inhibition further indicated that Desmodur N antigen reacted more readily with the patient's antibodies than did HDI or HMI antigens. These results suggest that the patient may have been exposed to HDI polyisocyanates in spray paint application. Use of Rast inhibition for diagnosis of sensitivity may indicate the precise sensitizing agent within a mixture.
Deckers, Susanne; Braren, Ingke; Greunke, Kerstin; Meyer, Nadine; Rühl, Dana; Bredehorst, Reinhard; Spillner, Edzard
2009-01-01
Nowadays, recombinant antibody and phage display technology enable the efficient generation of immunotools and a subsequent manipulation for optimized affinity, specificity or overall performance. Such advantages are of particular interest for haptenic target structures, such as TNT (2,4,6-trinitrotoluene). The toxicity of TNT and its breakdown products makes a reliable and fast detection of low levels in aqueous samples highly important. In the present study, we aimed for the generation of scFvs (single-chain antibody fragments) specific for the TNT-surrogate TNP (2,4,6-trinitrophenyl) and their subsequent production as monoclonal avian IgY immunoglobulins providing improved assay performance. Therefore we subjected a human synthetic scFv library to selection following different strategies. TNP-specific human antibody fragments could be identified, characterized for their primary structure and evaluated for production as soluble scFv in Escherichia coli. Additionally, a murine TNP-specific antibody fragment was obtained from the hybridoma 11B3; however, the prokaryotic expression level was found to be limited. To generate and evaluate immunoglobulin formats with superior characteristics, all recombinant antibody fragments then were converted into two different chimaeric bivalent IgY antibody formats. After expression in mammalian cells, the IgY antibodies were assessed for their reactivity towards TNT. The IgY antibodies generated on the basis of the combinatorial library proved to be useful for detection of TNT, thereby emphasizing the high potential of this approach for the development of detection devices for immunoassay-based techniques.
Reinders, Lars M H; Klassen, Martin D; Jaeger, Martin; Teutenberg, Thorsten; Tuerk, Jochen
2018-04-01
Monoclonal antibodies are a group of commonly used therapeutics, whose occupational health risk is still discussed controversially. The long-term low-dose exposure side effects are insufficiently evaluated; hence, discussions are often based on a theoretical level or extrapolating side effects from therapeutic dosages. While some research groups recommend applying the precautionary principle for monoclonal antibodies, others consider the exposure risk too low for measures taken towards occupational health and safety. However, both groups agree that airborne monoclonal antibodies have the biggest risk potential. Therefore, we developed a peptide-based analytical method for occupational exposure monitoring of airborne monoclonal antibodies. The method will allow collecting data about the occupational exposure to monoclonal antibodies. Thus, the mean daily intake for personnel in pharmacies and the pharmaceutical industry can be determined for the first time and will help to substantiate the risk assessment by relevant data. The introduced monitoring method includes air sampling, sample preparation and detection by liquid chromatography coupled with high-resolution mass spectrometry of individual monoclonal antibodies as well as sum parameter. For method development and validation, a chimeric (rituximab), humanised (trastuzumab) and a fully humanised (daratumumab) monoclonal antibody are used. A limit of detection between 1 μg per sample for daratumumab and 25 μg per sample for the collective peptide is achieved. Graphical abstract Demonstration of the analytical workflow, from the release of monoclonal antibodies to the detection as single substances as well as sum parameter.
Ring-Resonator/Sol-Gel Interferometric Immunosensor
NASA Technical Reports Server (NTRS)
Bearman, Gregory; Cohen, David
2007-01-01
A proposed biosensing system would be based on a combination of (1) a sensing volume containing antibodies immobilized in a sol-gel matrix and (2) an optical interferometer having a ring resonator configuration. The antibodies would be specific to an antigen species that one seeks to detect. In the ring resonator of the proposed system, light would make multiple passes through the sensing volume, affording greater interaction length and, hence, greater antibody- detection sensitivity.
Immunological disorders in chronic hepatitis C Egyptian patients.
Shaker, M K; Fahmy, H M
1997-01-01
It is known that hepatitis C virus (HCV) related to chronic liver disease may be associated with various immunological disorders, among these disorders are mixed cryoglobulinemia, serum antinuclear antibodies, antismooth muscle antibodies and liver/kidney microsomal antibody type 1 (LKM1). However, the actual prevalence and pathogenic role of these disorders in patients with chronic hepatitis C are unclear. It was our aim to estimate the prevalence of different autoimmune antibodies in cases of hepatitis C chronic liver disease and to assess if such changes have any clinical significance. A total of 30 chronic hepatitis C patients (22 males and 8 females) with a mean age of 43.5 +/- 6.7 years, all patients were ELISA II positive, HCV RNA PCR positive and HbsAg negative, with elevated ALT more than 2 folds of the normal, in addition to 20 healthy controls of matched age and sex were tested for rheumatoid factor, cryoglobulin, antinuclear antibody, antismooth muscle antibody, antimitochondrial antibody and LKM1. The rheumatoid factor was present in 18 (60%) of the HCV Ab +ve patients and in 1 (5%) of the controls (p < 0.0002), cryoglobulins were present in 4 (13.3%) of the patients and not detected in the controls (p > 0.24), antinuclear antibody was positive in 4 (13.3%) of the patients and in 1 (5%) of the controls (p > 0.6), antismooth muscle antibody was positive in 1 (3.3%) of the patients and not detected in any of the controls, the antimitochondrial antibody and LKM1 were not detected in both the patients and the controls. In conclusion, we can see that chronic hepatitis C patients show prevalence of some autoimmune antibodies and their presence is not associated with any implication on the clinical presentation.
Novel HIT antibody detection method using Sonoclot® coagulation analyzer.
Wanaka, Keiko; Asada, Reiko; Miyashita, Kumiko; Kaneko, Makoto; Endo, Hirokazu; Yatomi, Yutaka
2015-01-01
Since heparin-induced thrombocytopenia (HIT), caused by the generation of antibodies against platelet factor 4 (PF4)/heparin complexes (HIT antibodies), may induce serious complications due to thrombosis, a prompt diagnosis is desirable. Functional tests with platelet activation to detect HIT antibodies are useful for diagnosis of HIT, in particular (14)C-selotonin release assay (SRA). However, they are complicated and so can be performed only in limited laboratories. We tested if a blood coagulation test using Sonoclot® analyzer can serve for the detection of HIT antibodies. A murine monoclonal antibody (HIT-MoAb) against PF4/heparin complexes was used as an alternative to human HIT antibodies. To the mixture of HIT-MoAb and heparin (0.5 U/mL, final), whole blood obtained from a healthy volunteer was added, and then the activated clotting time (ACT), clot rate (CR), and area under the curve (AUC) were measured with Sonoclot® analyzer for 30minutes. The HIT-MoAb (30 to 100μg/mL, final) concentration dependently suppressed the anticoagulation activity (prolongation of ACT and decrease of CR and AUC) of heparin. The suppression of anticoagulation effect of heparin by HIT-MoAb was demonstrated by measurements using Sonoclot® analyzer. This method may provide a new tool for screening of HIT antibodies. Copyright © 2014 Elsevier Ltd. All rights reserved.
Muleme, Michael; Stenos, John; Vincent, Gemma; Campbell, Angus; Graves, Stephen; Warner, Simone; Devlin, Joanne M; Nguyen, Chelsea; Stevenson, Mark A; Wilks, Colin R; Firestone, Simon M
2016-06-01
Although many studies have reported the indirect immunofluorescence assay (IFA) to be more sensitive in detection of antibodies to Coxiella burnetii than the complement fixation test (CFT), the diagnostic sensitivity (DSe) and diagnostic specificity (DSp) of the assay have not been previously established for use in ruminants. This study aimed to validate the IFA by describing the optimization, selection of cutoff titers, repeatability, and reliability as well as the DSe and DSp of the assay. Bayesian latent class analysis was used to estimate diagnostic specifications in comparison with the CFT and the enzyme-linked immunosorbent assay (ELISA). The optimal cutoff dilution for screening for IgG and IgM antibodies in goat serum using the IFA was estimated to be 1:160. The IFA had good repeatability (>96.9% for IgG, >78.0% for IgM), and there was almost perfect agreement (Cohen's kappa > 0.80 for IgG) between the readings reported by two technicians for samples tested for IgG antibodies. The IFA had a higher DSe (94.8%; 95% confidence interval [CI], 80.3, 99.6) for the detection of IgG antibodies against C. burnetii than the ELISA (70.1%; 95% CI, 52.7, 91.0) and the CFT (29.8%; 95% CI, 17.0, 44.8). All three tests were highly specific for goat IgG antibodies. The IFA also had a higher DSe (88.8%; 95% CI, 58.2, 99.5) for detection of IgM antibodies than the ELISA (71.7%; 95% CI, 46.3, 92.8). These results underscore the better suitability of the IFA than of the CFT and ELISA for detection of IgG and IgM antibodies in goat serum and possibly in serum from other ruminants. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Stenos, John; Vincent, Gemma; Campbell, Angus; Graves, Stephen; Warner, Simone; Devlin, Joanne M.; Nguyen, Chelsea; Stevenson, Mark A.; Wilks, Colin R.; Firestone, Simon M.
2016-01-01
Although many studies have reported the indirect immunofluorescence assay (IFA) to be more sensitive in detection of antibodies to Coxiella burnetii than the complement fixation test (CFT), the diagnostic sensitivity (DSe) and diagnostic specificity (DSp) of the assay have not been previously established for use in ruminants. This study aimed to validate the IFA by describing the optimization, selection of cutoff titers, repeatability, and reliability as well as the DSe and DSp of the assay. Bayesian latent class analysis was used to estimate diagnostic specifications in comparison with the CFT and the enzyme-linked immunosorbent assay (ELISA). The optimal cutoff dilution for screening for IgG and IgM antibodies in goat serum using the IFA was estimated to be 1:160. The IFA had good repeatability (>96.9% for IgG, >78.0% for IgM), and there was almost perfect agreement (Cohen's kappa > 0.80 for IgG) between the readings reported by two technicians for samples tested for IgG antibodies. The IFA had a higher DSe (94.8%; 95% confidence interval [CI], 80.3, 99.6) for the detection of IgG antibodies against C. burnetii than the ELISA (70.1%; 95% CI, 52.7, 91.0) and the CFT (29.8%; 95% CI, 17.0, 44.8). All three tests were highly specific for goat IgG antibodies. The IFA also had a higher DSe (88.8%; 95% CI, 58.2, 99.5) for detection of IgM antibodies than the ELISA (71.7%; 95% CI, 46.3, 92.8). These results underscore the better suitability of the IFA than of the CFT and ELISA for detection of IgG and IgM antibodies in goat serum and possibly in serum from other ruminants. PMID:27122484
Bobosha, Kidist; Tjon Kon Fat, Elisa M; van den Eeden, Susan J F; Bekele, Yonas; van der Ploeg-van Schip, Jolien J; de Dood, Claudia J; Dijkman, Karin; Franken, Kees L M C; Wilson, Louis; Aseffa, Abraham; Spencer, John S; Ottenhoff, Tom H M; Corstjens, Paul L A M; Geluk, Annemieke
2014-05-01
Field-applicable tests detecting asymptomatic Mycobacterium leprae (M. leprae) infection or predicting progression to leprosy, are urgently required. Since the outcome of M. leprae infection is determined by cellular- and humoral immunity, we aim to develop diagnostic tests detecting pro-/anti-inflammatory and regulatory cytokines as well as antibodies against M. leprae. Previously, we developed lateral flow assays (LFA) for detection of cytokines and anti-PGL-I antibodies. Here we evaluate progress of newly developed LFAs for applications in resource-poor settings. The combined diagnostic value of IP-10, IL-10 and anti-PGL-I antibodies was tested using M. leprae-stimulated blood of leprosy patients and endemic controls (EC). For reduction of the overall test-to-result time the minimal whole blood assay time required to detect distinctive responses was investigated. To accommodate LFAs for field settings, dry-format LFAs for IP-10 and anti-PGL-I antibodies were developed allowing storage and shipment at ambient temperatures. Additionally, a multiplex LFA-format was applied for simultaneous detection of anti-PGL-I antibodies and IP-10. For improved sensitivity and quantitation upconverting phosphor (UCP) reporter technology was applied in all LFAs. Single and multiplex UCP-LFAs correlated well with ELISAs. The performance of dry reagent assays and portable, lightweight UCP-LF strip readers indicated excellent field-robustness. Notably, detection of IP-10 levels in stimulated samples allowed a reduction of the whole blood assay time from 24 h to 6 h. Moreover, IP-10/IL-10 ratios in unstimulated plasma differed significantly between patients and EC, indicating the feasibility to identify M. leprae infection in endemic areas. Dry-format UCP-LFAs are low-tech, robust assays allowing detection of relevant cytokines and antibodies in response to M. leprae in the field. The high levels of IP-10 and the required shorter whole blood assay time, render this cytokine useful to discriminate between leprosy patients and EC.
Bobosha, Kidist; Tjon Kon Fat, Elisa M.; van den Eeden, Susan J. F.; Bekele, Yonas; van der Ploeg-van Schip, Jolien J.; de Dood, Claudia J.; Dijkman, Karin; Franken, Kees L. M. C.; Wilson, Louis; Aseffa, Abraham; Spencer, John S.; Ottenhoff, Tom H. M.; Corstjens, Paul L. A. M.; Geluk, Annemieke
2014-01-01
Background Field-applicable tests detecting asymptomatic Mycobacterium leprae (M. leprae) infection or predicting progression to leprosy, are urgently required. Since the outcome of M. leprae infection is determined by cellular- and humoral immunity, we aim to develop diagnostic tests detecting pro-/anti-inflammatory and regulatory cytokines as well as antibodies against M. leprae. Previously, we developed lateral flow assays (LFA) for detection of cytokines and anti-PGL-I antibodies. Here we evaluate progress of newly developed LFAs for applications in resource-poor settings. Methods The combined diagnostic value of IP-10, IL-10 and anti-PGL-I antibodies was tested using M. leprae-stimulated blood of leprosy patients and endemic controls (EC). For reduction of the overall test-to-result time the minimal whole blood assay time required to detect distinctive responses was investigated. To accommodate LFAs for field settings, dry-format LFAs for IP-10 and anti-PGL-I antibodies were developed allowing storage and shipment at ambient temperatures. Additionally, a multiplex LFA-format was applied for simultaneous detection of anti-PGL-I antibodies and IP-10. For improved sensitivity and quantitation upconverting phosphor (UCP) reporter technology was applied in all LFAs. Results Single and multiplex UCP-LFAs correlated well with ELISAs. The performance of dry reagent assays and portable, lightweight UCP-LF strip readers indicated excellent field-robustness. Notably, detection of IP-10 levels in stimulated samples allowed a reduction of the whole blood assay time from 24 h to 6 h. Moreover, IP-10/IL-10 ratios in unstimulated plasma differed significantly between patients and EC, indicating the feasibility to identify M. leprae infection in endemic areas. Conclusions Dry-format UCP-LFAs are low-tech, robust assays allowing detection of relevant cytokines and antibodies in response to M. leprae in the field. The high levels of IP-10 and the required shorter whole blood assay time, render this cytokine useful to discriminate between leprosy patients and EC. PMID:24810599
Fragkoudis, Rennos; Dixon-Ballany, Catherine M; Zagrajek, Adrian K; Kedzierski, Lukasz; Fazakerley, John K
2018-05-18
Alphaviruses are mosquito-transmitted RNA viruses which generally cause acute disease including mild febrile illness, rash, arthralgia, myalgia and more severely, encephalitis. In the mouse, peripheral infection with Semliki Forest virus (SFV) results in encephalitis. With non-virulent strains, infectious virus is detectable in the brain, by standard infectivity assays, for around ten days. As we have shown previously, in severe combined immunodeficient (SCID) mice, infectious virus is detectable for months in the brain. Here we show that in MHC-II -/- mice, with no functional CD4 T-cells, infectious virus is also detectable in the brain for long periods. In contrast, in the brains of CD8 -/- mice, virus RNA persists but infectious virus is not detectable. In SCID mice infected with SFV, repeated intraperitoneal administration of anti-SFV immune serum rapidly reduced the titer of infectious virus in the brain to undetectable, however virus RNA persisted. Repeated intraperitoneal passive transfer of immune serum resulted in maintenance of brain virus RNA, with no detectable infectious virus, for several weeks. When passive antibody transfer was stopped, antibody levels declined and infectious virus was again detectable in the brain. In aged immunocompetent mice, previously infected with SFV, immunosuppression of antibody responses many months after initial infection also resulted in renewed ability to detect infectious virus in the brain. In summary, antiviral antibodies control and determine whether infectious virus is detectable in the brain but immune responses cannot clear this infection from the brain. Functional virus RNA capable of generating infectious virus persists and if antibody levels decline, infectious virus is again detectable.
Pan, Ruili; Jiang, Yujun; Sun, Luhong; Wang, Rui; Zhuang, Kejin; Zhao, Yueming; Wang, Hui; Ali, Md Aslam; Xu, Honghua; Man, Chaoxin
2018-05-01
Cronobacter sakazakii is an opportunistic foodborne pathogen that can infect newborns through powdered infant formula (PIF). In this study, we developed a novel enhanced lateral flow immunoassay (LFA) with enhanced sensitivity for detection of C. sakazakii in PIF by the naked eye. The proposed strategy for signal enhancement of the traditional LFA used concentrated gold nanoparticles (AuNP) as the enhancer to conjugate with capture antibodies, which could increase the immobilized capture antibodies concentration at the detection zone to improve capture efficiency. Besides, the detection signal was further amplified by accumulated AuNP as the C. sakazakii labeled with AuNP probes was captured by antibodies conjugated with enhancer at the test line. We also studied the effect of different concentrations of capture antibodies and concentrated AuNP on detection performance, and found that 2.2 mg/mL of capture antibodies and 0.06 nM concentrated AuNP were the optimal combination that could avoid a false-positive signal and maximally amplify the detection signal of the enhanced LFA. Using this strategy, the detection sensitivity of the enhanced LFA was 10 3 cfu/mL and improved 100-fold compared with traditional LFA. The strip was highly specific to C. sakazakii, and the time for detection of C. sakazakii in PIF was shortened by 3 h. In summary, the enhanced LFA developed by the addition of concentrated AuNP as the enhancer can be used as a sensitive, rapid, visual qualitative and point-of-care test method for detecting target analytes. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Critical review: assessment of interferon-β immunogenicity in multiple sclerosis.
Bendtzen, Klaus
2010-10-01
This review discusses type I interferon (IFN) immunogenicity with focus on methods of detection of anti-IFN antibodies in patients treated with human recombinant IFN-β. Pitfalls involved in the clinical use of various types of assays for binding antibodies and neutralizing antibodies against IFN-β are presented, and the widely held distinction between binding antibodies and neutralizing antibodies is questioned both in terms of detection and clinical importance. The article also addresses important bioavailability and pharmacokinetic issues occurring with prolonged use of protein drugs. The rationale for individualized or personalized medicine, ie, optimizing therapies according to individual needs rather than using standardized trial-and-error regimens to all patients, is highlighted.
Sonmez, Cemile; Coplu, Nilay; Gozalan, Aysegul; Akin, Lutfu; Esen, Berrin
2017-06-01
Detection of anti-tetanus antibody levels is necessary for both determination of the immune status of individuals and also for planning preventive measures. ELISA is the preferred test among in vitro tests however it can be affected by the cross reacting antibodies. A previously developed in-house ELISA test was found not reliable for the antibody levels ≤1.0IU/ml. A new method was developed to detect low antibody levels correctly. The aim of the present study was to compare the results of the newly developed in-house biotin-avidin tetanus IgG ELISA test with the in vivo mouse neutralization test, for the antibody levels ≤1.0IU/ml. A total of 54 serum samples with the antibody levels of three different levels, =0.01IU/ml, 0.01-0.1IU/ml, 0.1-1IU/ml, which were detected by in vivo mouse neutralization test were studied by the newly developed in-house biotin-avidin tetanus IgG ELISA test. Test was validated by using five different concentrations (0.01IU/ml, 0.06IU/ml, 0.2IU/ml, 0.5IU/ml, 1.0IU/ml). A statistically significant correlation (r 2 =0.9967 p=0,001) between in vivo mouse neutralization test and in-house biotin-avidin tetanus IgG ELISA test, was observed. For the tested concentrations intra-assay, inter-assay, accuracy, sensitivity, specificity and coefficients of variations were determined as ≤15%. In-house biotin-avidin tetanus IgG ELISA test can be an alternative method to in vivo mouse neutralization method for the detection of levels ≤1.0IU/ml. By using in-house biotin-avidin tetanus IgG ELISA test, individuals with non protective levels, will be reliably detected. Copyright © 2017. Published by Elsevier B.V.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richman, D.D.; Cleveland, P.H.; Oxman, M.N.
1981-05-01
A sensitive radioimmunoassay for serum antibody to varicella-zoster virus is described; it uses 125I-labeled staphylococcal protein A and a specially designed immunofiltration apparatus. The assay accurately distinguishes between individuals who are susceptible and those who are immune to infection with varicella-zoster virus. In addition, it can detect passive antibody in recipients of varicella-zoster immune globulin. This radioimmunoassay also detects the heterologous antibody responses that occasionally occur in patients infected with herpes simplex virus, which also have been detected by other antibody assays. The particular advantages of this assay are the use of noninfectious reagents, the speed of execution (less thanmore » 3 hr), the requirement for only small quantities of serum (30 microliters), the objectivity of end-point determination, and the capability of screening large numbers of sera. Consequently, this radioimmunoassay is especially useful for the rapid identification of susceptible individuals, which is essential for the appropriate management of patients and hospital personnel after exposure to varicella.« less
Gene, Robert W; Kumaran, Jyothi; Aroche, Cristina; van Faassen, Henk; Hall, J Christopher; MacKenzie, C Roger; Arbabi-Ghahroudi, Mehdi
2015-01-01
The need for rapid and easy technologies for the detection of food-borne and environmental pathogens is essential for safeguarding the health of populations. Furthermore, distribution of tainted food and water can have consequences which can affect whole economies. Antibodies and antibody fragments have been historically used in detection platforms due to their antigen specificity and robust physicochemical properties. In this study, we report the isolation and characterization of antibody fragments from the heavy chain antibody repertoire (VHH) of Camelidae which bind with specificity and high affinity to the Listeria monocytogenes invasin, Internalin B (InlB). To the best of our knowledge, this is the first report of anti-InlB VHHs from camelids. These anti-InlB VHHs were not cross-reactive to the structurally related Listeria invasin Internalin A (InlA) and are potential reagents to be used in the development of detection and medical technologies. Copyright © 2014. Published by Elsevier B.V.
Sorice, M; Pittoni, V; Griggi, T; Losardo, A; Leri, O; Magno, M S; Misasi, R; Valesini, G
2000-01-01
The antigen specificity of anti-phospholipid antibodies in infectious mononucleosis (IM) was studied using ELISA for the detection of anti-β2-glycoprotein I (β2-GPI), anti-annexin V, anti-protein S and anti-prothrombin antibodies and TLC immunostaining for the detection of anti-phospholipid antibodies. This technique enabled us to look at antibodies reacting to ‘pure’ phospholipid antigens in the absence of protein contamination. Sera from 46 patients with IM, 18 with systemic lupus erythematosus (SLE), 21 with primary anti-phospholipid antibody syndrome (PAPS), 50 with Helicobacter pylori infection and 30 healthy blood donors were tested. This study highlights anti-phospholipid antibodies in patients with IM as specific ‘pure’ anti-cardiolipin antibodies, while in PAPS and SLE patients anti-phosphatidylserine and anti-phosphatidylethanolamine antibodies were also found. This investigation also shows that the anti-cardiolipin antibodies found in IM can be present with anti-cofactor protein antibodies. The higher prevalence of anti-cofactor antibodies found in IM sera than in Helicobacter pylori sera may be due to the immunostimulatory effect and/or the polyclonal activation often observed in course of Epstein–Barr virus infection. However, anti-β2-GPI and, to a lesser extent, anti-prothrombin antibodies occur with a significantly lower prevalence in IM than in PAPS patients. This finding suggests that these antibodies should be regarded as the expression of the broad autoimmune syndrome involving the phospholipid-binding plasma proteins. PMID:10792380
Langan, Leanne L; D'Orsogna, Lloyd; Park, Lawrence P; Hughes, Tiffany L; Irish, Ashley; Luxton, Grant; Witt, Campbell S; Christiansen, Frank T
2006-01-01
In a previous study, we have shown that HLA class II antibodies and a high soluble CD30 (sCD30) measured at least 1 year post-transplant predict subsequent graft failure. We have now updated the results of this same cohort of 208 patients 15 months later. HLA-specific antibodies (class I and class II) were detected by ELISA LAT-M and Luminex LabScreen assays. Data on graft outcome was collected with a median follow-up of 4.7 years. By Kaplan-Meier analysis, class II antibody was again associated with a poorer outcome, with an estimated 6-year graft survival of 67% and 71% when detected by ELISA and Luminex, respectively, compared with 92% for those without class II antibody (p < or = 0.0001). A soluble CD30 level of > or = 100 U/ml was also associated with a poorer estimated 6-year graft survival (p = 0.02). HLA antibodies and high sCD30 (> or = 100 U/ml) had an additive effect such that those with both high sCD30 and class II antibodies had a hazard ratio for subsequent graft failure of 18.1 (p = 0.0008) and 8.6 (p = 0.007) when detected by ELISA and Luminex, respectively. These data show that detection of HLA class II antibodies and serum sCD30 measured at least 1 year post-transplant continues to predict a subsequent outcome up to 6 years after the initial measurement; they also show that such measures provide important information that may allow for modification of ongoing therapy.
NASA Astrophysics Data System (ADS)
Neuweiler, Hannes; Scheffler, Silvia; Sauer, Markus
2005-08-01
The development of reliable methods for the detection of minute amounts of antibodies directly in homogeneous solution represents one of the major tasks in the current research field of molecular diagnostics. We demonstrate the potential of fluorescence correlation spectroscopy (FCS) in combination with quenched peptide-based fluorescence probes for sensitive detection of p53 antibodies directly in homogeneous solution. Single tryptophan (Trp) residues in the sequences of short, synthetic peptide epitopes of the human p53 protein efficiently quench the fluorescence of an oxazine fluorophore attached to the amino terminal ends of the peptides. The fluorescence quenching mechanism is thought to be a photoinduced electron transfer reaction from Trp to the dye enabled by the formation of intramolecular complexes between dye and Trp. Specific recognition of the epitope by the antibody confines the conformational flexibility of the peptide. Consequently, complex formation between dye and Trp is abolished and fluorescence is recovered. Using fluorescence correlation spectroscopy (FCS), antibody binding can be monitored observing two parameters simultaneously: the diffusional mobility of the peptide as well as the quenching amplitude induced by the conformational flexibility of the peptide change significantly upon antibody binding. Our data demonstrate that FCS in combination with fluorescence-quenched peptide epitopes opens new possibilities for the reliable detection of antibody binding events in homogeneous solution.
Immunoglobulin M antibodies are not specific for serodiagnosis of human toxocariasis.
Roldán, W H; Elefant, G R; Ferreira, A W
2017-08-01
Serodiagnosis of human toxocariasis is established by detecting serum anti-Toxocara IgG antibodies, but there is little knowledge regarding the reactivity of human IgM antibodies against the Toxocara antigens. In this study, we have evaluated the reactivity of IgM antibodies in sera from patients with toxocariasis, patients with other helminth infections, and healthy individuals, against Toxocara larval excretory-secretory (TES) antigens by enzyme-linked immunosorbent assay (ELISA) and Western blot (WB). Anti-Toxocara IgM were detected in 91.4% of sera from patients with toxocariasis, 76% of sera from patients with other helminth infections, and 45.3% of sera from healthy individuals when ELISA was used. Likewise, IgM antibodies were detected in 94.8% of sera from patients with toxocariasis, 65.3% of sera from patients with other helminth infections, and 41% of sera from healthy individuals when WB was used. This reactivity exhibited only a slight decrease when the TES antigens were deglycosylated, showing that not only glycosidic epitopes, but also peptide epitopes are involved in the recognition and binding of IgM antibodies during the immune response against the parasite. The results shown that IgM antibodies are not specific for serodiagnosis of human toxocariasis. © 2017 John Wiley & Sons Ltd.
Zhang, Yeping; Zhu, Ping; Shi, Yongjin; Liu, Jihua; Pu, Dingfang; Cao, Xianghong; Zhu, Qiang; Wang, Yijia; Ma, Mingxin; Yu, Jiren
2002-02-01
To investigate the anti-human CEM lymphoma cell activities induced by TCR idiotypic DNA vaccine containing different antigen determinants in BALB/c mice. The specific rearranged gene fragment encoding TCRVbeta region of CEM cell line was obtained by RT-PCR technique. The PCR product was cloned into eukaryocytic expression vector pcDNA3, which was used as DNA vaccine and template for PCR amplifying different antigen determinant. Gene fragments encoding different antigen determinant were amplified and cloned into pcDNA3, separately. The experimental mice were immunized by intramuscular injection of the DNA vaccines. The specific anti-idiotype antibodies were detected by indirect immunofluorescence assay. TCRbetaV of CEM cell line contains five antigen determinants. Specific anti-idiotype antibody was detected in all of the six mice immunized with DNA vaccine containing all the five determinants (the highest titer was 1:480). Although the antibody could also be detected in four of the six mice immunized with DNA vaccine containing four of the five antigen determinants, the antibody titer was lower (the highest titer was 1:80). DNA vaccine containing two of the five determinants could not induce the specific antibody. The idiotypic DNA vaccine containing the whole TCRbetaV five antigen determinants could induce the specific anti-lymphoma idiotypic antibody in BALB/c mice.
Porter, R; van der Logt, P; Howell, S; Kyröläinen-Reay, M; Badley, A
2001-12-01
Most immunoassays currently rely on optical methods for signal generation e.g. in ELISA and rapid assay formats. It has become apparent as in the Glucose sensor market that there is a need for simple direct electrical immuno-sensors. We have investigated the novel use of organic conducting monolayers used as a direct electrochemical detection support for an immuno-reaction. It was found that antibodies raised to a carbazole dimer monolayer could increase the charge movement across that monolayer surface. Antibody fragments were taken from a specific anti-carbazole antibody fragment library and combined with an antibody fragment directed to the hormone estrone 3 glucuronide (E3G), the target antigen to form a bispecific antibody fragment. The device utilised these specific antibody fragments and incorporated them on the top plate of a capillary fill format as the immuno-assay components. The immuno-reaction utilised a competition assay. Free E3G analyte in the sample displaced the bispecific antibody fragment from the immuno-surface leaving it free to bind the carbazole monolayer surface. There the binding was detected using amperometric or coulometric methods. By combining all there element it was possible to develop a sensitive immuno-assay that could detect E3G in a reproducible calibrated fashion down to 10 ng/ml.
Alderete, J F
1984-06-01
An enzyme linked immunosorbent assay (ELISA) for detecting antibody to antigenic Trichomonas vaginalis macromolecules has been identified using whole cells or an aqueous protein extract as antigen. The test was developed under optimum conditions using serum samples from experimental animals. The sensitivity of the ELISA was equal to or greater than that obtained by radioimmunoprecipitation and electrophoresis-fluorography techniques. The ELISA was capable of assessing antibody responses during the development of lesions in animals inoculated subcutaneously and it reproducibly measured the individual classes immunoglobulins directed at T vaginalis. The colorimetric assay was also suitable for showing cross reactivity between trichomonal species as well as between different strains of T vaginalis. Conditions established for monitoring antibody to trichomanads in immunised rabbits or infected mice were equally effective for human materials, such as serum or vaginal washes. Serum from experimental animals or infected people showed high concentrations of IgG, IgA, and IgM antibody to trichomonads. Only antibodies of the IgG and IgA class were detected in vaginal washes from women with acute trichomoniasis. No IgE antibody to trichomonads was found under a variety of conditions in serum samples from patients or experimental animals.
Ochratoxin A Detection on Antibody- Immobilized on BSA-Functionalized Gold Electrodes.
Badea, Mihaela; Floroian, Laura; Restani, Patrizia; Cobzac, Simona Codruta Aurora; Moga, Marius
2016-01-01
Ochratoxin A (OTA)-a toxin produced by Aspergillus carbonarius, Aspergillus ochraceus, and Penicillium verrucosum-is one of the most-abundant food-contaminating mycotoxins. To avoid the risk of OTA consumption for humans and animals, the rapid detection and quantitation of OTA level in different commodities are of great importance. In this work, an impedimetric immunosensor for ochratoxin A (OTA) detection, a common toxic botanical contaminant, was developed via the immobilization of anti-OTA antibody on bovine serum albumin modified gold electrodes. A four-step reaction protocol was tested to modify the gold electrode and obtain the sensing substrate. All the steps of the immunosensor elaboration and also the immunochemical reaction between surface-bound antibody and ochratoxin A were analyzed using cyclic voltammetry and electrochemical impedance spectroscopy. Modification of the impedance due to the specific antigen-antibody reaction at immunosensor surface, was used in order to detect ochratoxin A. Linear proportionality of the charge transfer resistance to the concentration of OTA allows ochratoxin A detection in the range of 2.5-100 ng/mL.
A Quartz Crystal Microbalance Immunosensor for Stem Cell Selection and Extraction
Costanzo, Salvatore; Zambrano, Gerardo; Mauro, Marco; Battaglia, Raffaele; Ferrini, Gianluca; Nastri, Flavia; Pavone, Vincenzo
2017-01-01
A cost-effective immunosensor for the detection and isolation of dental pulp stem cells (DPSCs) based on a quartz crystal microbalance (QCM) has been developed. The recognition mechanism relies on anti-CD34 antibodies, DPSC-specific monoclonal antibodies that are anchored on the surface of the quartz crystals. Due to its high specificity, real time detection, and low cost, the proposed technology has a promising potential in the field of cell biology, for the simultaneous detection and sorting of stem cells from heterogeneous cell samples. The QCM surface was properly tailored through a biotinylated self-assembled monolayer (SAM). The biotin–avidin interaction was used to immobilize the biotinylated anti-CD34 antibody on the gold-coated quartz crystal. After antibody immobilization, a cellular pellet, with a mixed cell population, was analyzed; the results indicated that the developed QCM immunosensor is highly specific, being able to detect and sort only CD34+ cells. Our study suggests that the proposed technology can detect and efficiently sort any kind of cell from samples with high complexity, being simple, selective, and providing for more convenient and time-saving operations. PMID:29182568
Zhou, Yu; Tian, Xiang-Li; Li, Yan-Song; Pan, Feng-Guang; Zhang, Yuan-Yuan; Zhang, Jun-Hui; Wang, Xin-Rui; Ren, Hong-Lin; Lu, Shi-Ying; Li, Zhao-Hui; Liu, Zeng-Shan; Chen, Qi-Jun; Liu, Jing-Qiu
2012-12-15
Abrin is a plant toxin, which can be easily isolated from the seeds of Abrus precatorius. It may be used as a biological warfare agent. In order to detect abrin in food samples, a two-layer sandwich format enzyme-linked immunosorbent assay based on the monoclonal antibody (mAb) (as capture antibody) and rabbit polyclonal serum (as detecting antibody) was developed and applied for the determination of abrin in some food matrices. The linear range of the mAb was 1-100 μg L(-1) with a detection limit of 0.5 μg L(-1) for abrin in phosphate buffered saline (PBS). The recoveries of abrin from sausage, beer and milk samples ranged 97.5-98.6%, 95.8-98.4% and 94.8-9.6%, respectively, with a coefficient of variation (CV) of 3.7% or less. The newly developed sandwich ELISA using the mAb appears to be a reliable and useful method for detection of abrin in sausage, beer and milk. Copyright © 2012 Elsevier Ltd. All rights reserved.
Mason, L J; Ravirajan, C T; Latchman, D S; Isenberg, D A
2001-01-01
There are few studies assessing the pathogenicity of human monoclonal anti-DNA antibodies. The use of SCID mice avoids the problem of rejection of the human hybridoma cells thus allowing in vivo assessment of human immunoglobulins. Using electron microscopy we have shown that the human IgG anti-dsDNA monoclonal antibody, RH14, is nephritogenic in SCID mice, causing morphological changes in the kidney due to immunoglobulin deposition. The problem with using SCID mice is that they have an abnormal immune system; normally they are used at about 2 months of age, at which time they have virtually no functional T or B cells. It is known that older SCID mice become increasingly ‘leaky’, that is they develop some mature lymphocyte clones. Our aim was to assess if implanting anti-DNA antibodies into older ‘leaky’ SCID mice would result in pathology which was observable by light microscopy. Eight-month-old SCID mice were implanted with human hybridoma cells secreting either RH14 an anti-dsDNA IgG, CL24, an antiphospholipid antibody or an irrelevant human IgG control. As previously, RH14 deposited in the kidney and caused proteinuria but unexpectedly we also observed hyaline thrombi in the kidney glomeruli and peritubular capillaries. These thrombi occurred only in the case of RH14 implanted mice and were found to stain positively for human IgG and fibrin. However, apart from the interesting thrombi, we did not observe any greater pathological damage resulting from the anti-dsDNA antibody deposition than we had seen in the younger mice; indeed, the electron microscopic findings were more limited. PMID:11678910
Patra, Kailash P.; Saito, Mayuko; Atluri, Vidya L.; Rolán, Hortensia G.; Young, Briana; Kerrinnes, Tobias; Smits, Henk; Ricaldi, Jessica N.; Gotuzzo, Eduardo; Gilman, Robert H.; Tsolis, Renee M.; Vinetz, Joseph M.
2014-01-01
Human brucellosis is most commonly diagnosed by serology based on agglutination of fixed Brucella abortus as antigen. Nucleic acid amplification techniques have not proven capable of reproducibly and sensitively demonstrating the presence of Brucella DNA in clinical specimens. We sought to optimize a monoclonal antibody-based assay to detect Brucella melitensis lipopolysaccharide in blood by conjugating B. melitensis LPS to keyhole limpet hemocyanin, an immunogenic protein carrier to maximize IgG affinity of monoclonal antibodies. A panel of specific of monoclonal antibodies was obtained that recognized both B. melitensis and B. abortus lipopolysaccharide epitopes. An antigen capture assay was developed that detected B. melitensis in the blood of experimentally infected mice and, in a pilot study, in naturally infected Peruvian subjects. As a proof of principle, a majority (7/10) of the patients with positive blood cultures had B. melitensis lipopolysaccharide detected in the initial blood specimen obtained. One of 10 patients with relapsed brucellosis and negative blood culture had a positive serum antigen test. No seronegative/blood culture negative patients had a positive serum antigen test. Analysis of the pair of monoclonal antibodies (2D1, 2E8) used in the capture ELISA for potential cross-reactivity in the detection of lipopolysaccharides of E. coli O157:H7 and Yersinia enterocolitica O9 showed specificity for Brucella lipopolysaccharide. This new approach to develop antigen-detection monoclonal antibodies against a T cell-independent polysaccharide antigen based on immunogenic protein conjugation may lead to the production of improved rapid point-of-care-deployable assays for the diagnosis of brucellosis and other infectious diseases. PMID:24901521
Li, Xiaoyang; Pomares, Christelle; Gonfrier, Géraldine; Koh, Byumseok; Zhu, Shoujun; Gong, Ming
2016-01-01
Toxoplasmosis is an infection caused by the protozoan parasite Toxoplasma gondii that can lead to severe sequelae in the fetus during pregnancy. Definitive serologic diagnosis of the infection during gestation is made mostly by detecting T. gondii-specific antibodies, including IgG and IgM, individually in a single serum sample by using commercially available kits. The IgA test is used by some laboratories as an additional marker of acute infection. Most of the commercial tests have failed to reach 100% correlation with the reference method, the Sabin-Feldman dye test for the detection of Toxoplasma IgG antibodies. For Toxoplasma IgM and IgA antibodies, there is no reference method and their evaluation is done by comparing the results of one assay to those of another. There is a need for multiplexed assay platforms, as the serological diagnosis of T. gondii infection does not rely on the detection of a single Ig subtype. Here we describe the development of a plasmonic gold chip with vast fluorescence enhancement in the near-infrared region for simultaneous detection of IgG, IgM, and IgA antibodies against T. gondii in an ∼1-μl serum or whole-blood sample. When 168 samples were tested on this platform, IgG antibody detection sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were all 100%. IgM antibody detection achieved 97.6% sensitivity and 96.9% specificity with a 90.9% PPV and a 99.2% NPV. Thus, the nanoscience-based plasmonic gold platform enables a high-performance, low-cost, multiplexed assay requiring ultrasmall blood volumes, paving the way for the implementation of universal screening for toxoplasmosis infection during gestation. PMID:27008879
Liu, Jinny L; Zabetakis, Dan; Acevedo-Vélez, Glendalys; Goldman, Ellen R; Anderson, George P
2013-01-08
Antibodies are commonly used as recognition elements in immunoassays because of their high specificity and affinity, and have seen extensive use in competitive assays for the detection of small molecules. However, these complex molecules require production either in animals or by mammalian cell cultures, and are not easily tailored through genetic manipulation. Single chain antibodies (scFv), recombinantly expressed molecules consisting of only the antibody's binding region joined via a linking peptide, can provide an alternative to intact antibodies. We describe the characterization of a new monoclonal antibody (mAb), 2G5B5, able to detect the small molecule explosive 2,4,6-trinitrotoluene (TNT) and the scFv derived from its variable regions. The mAb and scFv were tested by surface plasmon resonance to determine their affinity for an immobilized TNT surrogate; dissociation constants were determined to be 1.5×10(-13) M and 4.8×10(-10) M respectively. Circular dichroism was used to determine their melting temperatures. The mAb is more stable melting at ∼75°C while the scFv melts at ∼65°C. The recognition elements were incorporated into a competitive assay format using a bead-based multiplexing platform to examine their sensitivity and specificity. The scFv was able to detect TNT ∼10-fold more sensitively than the mAb in this assay format, allowing detection of TNT concentrations down to at least 1 μg L(-1). The 2G5B gave similar detection limits to a commercial anti-TNT mAb, but was less specific, recognizing 1,3,5-trinitrobenzene (TNB) equally well as TNT. Published by Elsevier B.V.
[Targeted detecting HER2 expression with recombinant anti HER2 ScFv-GFP fusion antibody].
Gao, Guohui; Chen, Chong; Yang, Yanmei; Yang, Han; Wang, Jindan; Zheng, Yi; Huang, Qidi; Hu, Xiaoqu
2012-08-01
To verify the reliability of targeted detecting HER2 positive cancer cells and clinical pathological tissue specimens with a recombinant anti HER2 single chain antibody in single chain Fv fragment (scFv) format, we have constructed the fusion variable regions of the ScFv specific for HER2/neu. labeled a green-fluorescent protein(GFP). The humanized recombinant Anti HER2 ScFv-GFP gene was inserted into pFast Bac HT A, and expressed in insect cells sf9. Then the recombinant fusion protein Anti HER2 ScFv-GFP was properly purified with Ni2+-NTA affinity chromatography from the infected sf9 cells used to test the specificity of the fusion antibody for HER2 positive cancer cells. Firstly, the purified antibody incubated with HER2 positive breast cancer cells SKBR3, BT474 and HER2 negative breast cancer cells MCF7 for 12 h/24 h/48 h at 37 degrees C, in order to confirm targeted detecting HER2 positive breast cancer cells by Laser Confocal Microscopy. Furthermore, the same clinical pathological tissue samples were assessed by immunohistochemistry (IHC) and the fusion antibody Anti HER2 ScFv-GFP in the meanwhile. The data obtained indicated that the recombinant eukaryotic expression plasmid pFast Bac HT A/Anti HER2 ScFv-GFP was constructed successfully In addition, obvious green fluorescent was observed in insect cells sf9. When the purified fusion antibody was incubated with different cancer cells, much more green fluorescent was observed on the surface of the HER2 positive cancer cells SKBR3 and BT474. In contrast, no green fluorescent on the surface of the HER2 negative cancer cells MCF7 was detected. The concentration of the purified fusion antibody was 115.5 microg/mL, of which protein relative molecular weight was 60 kDa. The analysis showed the purity was about 97% and the titer was about 1:64. The detection results of IHC and fusion antibody testing indicated the conformity. In summary, the study showed that the new fusion antibody Anti HER2 ScFv-GFP can test HER2 positive cancer cells, indicating a potential candidate method for clinical HER2 positive specimens detection.
Ochiai, T.; Yasutake, W.T.; Gould, R.W.
1985-01-01
The direct fluorescent antibody technique (FAT) was successfully used to detect the causative agent of bacterial kidney disease (BKD), Renibacterium salmoninarum, in Bouin's solution flexed and paraffinembedded egg and tissue sections. This method is superior to gram stain and may be particularly useful in detecting the BKD organism in fish with low-grade infection.
Serum Dried Samples to Detect Dengue Antibodies: A Field Study.
Maldonado-Rodríguez, Angelica; Rojas-Montes, Othon; Vazquez-Rosales, Guillermo; Chavez-Negrete, Adolfo; Rojas-Uribe, Magdalena; Posadas-Mondragon, Araceli; Aguilar-Faisal, Leopoldo; Cevallos, Ana Maria; Xoconostle-Cazares, Beatriz; Lira, Rosalia
2017-01-01
Dried blood and serum samples are useful resources for detecting antiviral antibodies. The conditions for elution of the sample need to be optimized for each disease. Dengue is a widespread disease in Mexico which requires continuous surveillance. In this study, we standardized and validated a protocol for the specific detection of dengue antibodies from dried serum spots (DSSs). Paired serum and DSS samples from 66 suspected cases of dengue were collected in a clinic in Veracruz, Mexico. Samples were sent to our laboratory, where the conditions for optimal elution of DSSs were established. The presence of anti-dengue antibodies was determined in the paired samples. DSS elution conditions were standardized as follows: 1 h at 4°C in 200 µ l of DNase-, RNase-, and protease-free PBS (1x). The optimal volume of DSS eluate to be used in the IgG assay was 40 µ l. Sensitivity of 94%, specificity of 93.3%, and kappa concordance of 0.87 were obtained when comparing the antidengue reactivity between DSSs and serum samples. DSS samples are useful for detecting anti-dengue IgG antibodies in the field.
Serum Dried Samples to Detect Dengue Antibodies: A Field Study
Maldonado-Rodríguez, Angelica; Rojas-Montes, Othon; Chavez-Negrete, Adolfo; Rojas-Uribe, Magdalena; Posadas-Mondragon, Araceli; Aguilar-Faisal, Leopoldo; Xoconostle-Cazares, Beatriz
2017-01-01
Background Dried blood and serum samples are useful resources for detecting antiviral antibodies. The conditions for elution of the sample need to be optimized for each disease. Dengue is a widespread disease in Mexico which requires continuous surveillance. In this study, we standardized and validated a protocol for the specific detection of dengue antibodies from dried serum spots (DSSs). Methods Paired serum and DSS samples from 66 suspected cases of dengue were collected in a clinic in Veracruz, Mexico. Samples were sent to our laboratory, where the conditions for optimal elution of DSSs were established. The presence of anti-dengue antibodies was determined in the paired samples. Results DSS elution conditions were standardized as follows: 1 h at 4°C in 200 µl of DNase-, RNase-, and protease-free PBS (1x). The optimal volume of DSS eluate to be used in the IgG assay was 40 µl. Sensitivity of 94%, specificity of 93.3%, and kappa concordance of 0.87 were obtained when comparing the antidengue reactivity between DSSs and serum samples. Conclusion DSS samples are useful for detecting anti-dengue IgG antibodies in the field. PMID:28630868
Multiple Strategy Bio-Detection Sensor Platforms Made From Carbon and Polymer Materials
2006-08-10
binding of antigens. Further investigations were conducted on the antibody-antigen detection scheme using known test antigens (i.e. bacteria ). While...this method worked in preliminary studies, the use of antibodies was determined not to be feasible for detecting many different types of bacteria in...solution. Also, as the number of bacteria in a solution increased, it became necessary to wash the detection surface more extensively to favor specific
Infrared small target detection based on Danger Theory
NASA Astrophysics Data System (ADS)
Lan, Jinhui; Yang, Xiao
2009-11-01
To solve the problem that traditional method can't detect the small objects whose local SNR is less than 2 in IR images, a Danger Theory-based model to detect infrared small target is presented in this paper. First, on the analog with immunology, the definition is given, in this paper, to such terms as dangerous signal, antigens, APC, antibodies. Besides, matching rule between antigen and antibody is improved. Prior to training the detection model and detecting the targets, the IR images are processed utilizing adaptive smooth filter to decrease the stochastic noise. Then at the training process, deleting rule, generating rule, crossover rule and the mutation rule are established after a large number of experiments in order to realize immediate convergence and obtain good antibodies. The Danger Theory-based model is built after the training process, and this model can detect the target whose local SNR is only 1.5.
Gold Nanoparticles-Based Barcode Analysis for Detection of Norepinephrine.
An, Jeung Hee; Lee, Kwon-Jai; Choi, Jeong-Woo
2016-02-01
Nanotechnology-based bio-barcode amplification analysis offers an innovative approach for detecting neurotransmitters. We evaluated the efficacy of this method for detecting norepinephrine in normal and oxidative-stress damaged dopaminergic cells. Our approach use a combination of DNA barcodes and bead-based immunoassays for detecting neurotransmitters with surface-enhanced Raman spectroscopy (SERS), and provides polymerase chain reaction (PCR)-like sensitivity. This method relies on magnetic Dynabeads containing antibodies and nanoparticles that are loaded both with DNA barcords and with antibodies that can sandwich the target protein captured by the Dynabead-bound antibodies. The aggregate sandwich structures are magnetically separated from the solution and treated to remove the conjugated barcode DNA. The DNA barcodes are then identified by SERS and PCR analysis. The concentration of norepinephrine in dopaminergic cells can be readily detected using the bio-barcode assay, which is a rapid, high-throughput screening tool for detecting neurotransmitters.
Detection of dopamine in dopaminergic cell using nanoparticles-based barcode DNA analysis.
An, Jeung Hee; Kim, Tae-Hyung; Oh, Byung-Keun; Choi, Jeong Woo
2012-01-01
Nanotechnology-based bio-barcode-amplification analysis may be an innovative approach to dopamine detection. In this study, we evaluated the efficacy of this bio-barcode DNA method in detecting dopamine from dopaminergic cells. Herein, a combination DNA barcode and bead-based immunoassay for neurotransmitter detection with PCR-like sensitivity is described. This method relies on magnetic nanoparticles with antibodies and nanoparticles that are encoded with DNA, and antibodies that can sandwich the target protein captured by the nanoparticle-bound antibodies. The aggregate sandwich structures are magnetically separated from solution, and treated in order to remove the conjugated barcode DNA. The DNA barcodes were then identified via PCR analysis. The dopamine concentration in dopaminergic cells can be readily and rapidly detected via the bio-barcode assay method. The bio-barcode assay method is, therefore, a rapid and high-throughput screening tool for the detection of neurotransmitters such as dopamine.
Piezoelectric microcantilever serum protein detector
NASA Astrophysics Data System (ADS)
Capobianco, Joseph A.
The development of a serum protein detector will provide opportunities for better screening of at-risk cancer patients, tighter surveillance of disease recurrence and better monitoring of treatment. An integrated system that can process clinical samples for a number of different types of biomarkers would be a useful tool in the early detection of cancer. Also, screening biomarkers such as antibodies in serum would provide clinicians with information regarding the patient's response to treatment. Therefore, the goal of this study is to develop a sensor which can be used for rapid, all-electrical, real-time, label-fee, in-situ, specific quantification of cancer markers, e.g., human epidermal receptor 2 (Her2) or antibodies, in serum. To achieve this end, piezoelectric microcantilever sensors (PEMS) were constructed using an 8 mum thick lead magnesium niobate-lead titanate (PMN-PT) freestanding film as the piezoelectric layer. The desired limit of detection is on the order of pg/mL. In order to achieve this goal the higher frequency lateral extension modes were used. Also, as the driving and sensing of the PEMS is electrical, the PEMS must be insulated in a manner that allows it to function in aqueous solutions. The insulation layer must also be compatible with standardized bioconjugation techniques. Finally, detection of both cancer antigens and antibodies in serum was carried out, and the results were compared to a standard commercialized protocol. PEMS have demonstrated the capability of detecting Her2 at a concentration of 5 pg/mL in diluted human serum (1:40) in less than 1 hour. The approach can be easily translated into the clinical setting because the sensitivity is more than sufficient for monitoring prognosis of breast cancer patients. In addition to Her2 detection, antibodies in serum were assayed in order to demonstrate the feasibility of monitoring the immune response for antibody-dependent cellular cytotoxicity (ADCC) in patients on antibody therapies such as Herceptin and Cetuximab. The PEMS displayed a limit of detection of 100 fg/mL, which was 100 times lower than the current methods of protein detection in serum, such as ELISA. Furthermore, the sensitivity of the PEMS device allows it to be capable of determining the dissociation constant, K d, of selective receptors such as antibodies. Using the dose response trials of Her2, Kd has been deduced for H3 scFv, and Herceptin, a commercial antibody specific for Her2.
Recombinant Phage Probes for Salmonella Typhimurium Detection
2005-03-23
food safety analysis that are slower, labor-intensive, and cost-inefficient. Confirmation of presence in food products can take as long as 48 hours by conventional culture. Current rapid detection initiatives include biosensors that routinely incorporate antibodies as the biorecognition unit. Although sensitive and specific, antibodies are costly and may degrade under unfavorable environmental conditions. We believe that a stable, inexpensive substitute for antibodies is filamentous phage manipulated through phage display technique then affinity selected for specificity to
Development and immunochemical evaluation of a novel chicken IgY antibody specific for KLK6.
Sotiropoulou, Georgia; Pampalakis, Georgios; Prosnikli, Evangelia; Evangelatos, Gregory P; Livaniou, Evangelia
2012-12-05
Human kallikrein-related peptidase 6 (KLK6) has been implicated in various types of cancer and in neurodegenerative and demyelinating diseases including multiple sclerosis. Further, anti-KLK6 antibodies attenuated disease manifestations in the mouse model of multiple sclerosis. Availability of specific antibodies against KLK6 is fundamental to the development of improved diagnostic and/or immunotherapeutic applications. Here, we exploited the enhanced immunogenicity of mammalian proteins in avian species to generate a polyclonal antibody against KLK6. Chicken were immunized with recombinant KLK6 and antibodies Y (IgYs) were purified from egg yolk with a simple procedure and evaluated for KLK6 detection by ELISA and Western blot using recombinant proteins and human cell lysates and supernatants. The anti-KLK6 Y polyclonal exhibited high affinity for KLK6 with a detection limit of 30 fmol. On the other hand, the widely used rabbit polyclonal antibody that was raised against the same recombinant KLK6 had a detection limit of 300 fmol. Moreover, the IgYs did not display any crossreactivity with recombinant KLKs or endogenous KLKs and other cellular proteins. Based on its high specificity and sensitivity the developed anti-KLK6 IgY is expected to aid the development of improved diagnostic tools for the detection of KLK6 in biological and clinical samples.
Development and immunochemical evaluation of a novel chicken IgY antibody specific for KLK6
2012-01-01
Background Human kallikrein-related peptidase 6 (KLK6) has been implicated in various types of cancer and in neurodegenerative and demyelinating diseases including multiple sclerosis. Further, anti-KLK6 antibodies attenuated disease manifestations in the mouse model of multiple sclerosis. Availability of specific antibodies against KLK6 is fundamental to the development of improved diagnostic and/or immunotherapeutic applications. Here, we exploited the enhanced immunogenicity of mammalian proteins in avian species to generate a polyclonal antibody against KLK6. Results Chicken were immunized with recombinant KLK6 and antibodies Y (IgYs) were purified from egg yolk with a simple procedure and evaluated for KLK6 detection by ELISA and Western blot using recombinant proteins and human cell lysates and supernatants. The anti-KLK6 Y polyclonal exhibited high affinity for KLK6 with a detection limit of 30 fmol. On the other hand, the widely used rabbit polyclonal antibody that was raised against the same recombinant KLK6 had a detection limit of 300 fmol. Moreover, the IgYs did not display any crossreactivity with recombinant KLKs or endogenous KLKs and other cellular proteins. Conclusions Based on its high specificity and sensitivity the developed anti-KLK6 IgY is expected to aid the development of improved diagnostic tools for the detection of KLK6 in biological and clinical samples. PMID:23216878
Development of Prototype Filovirus Recombinant Antigen Immunoassays
Boisen, Matt L.; Oottamasathien, Darin; Jones, Abigail B.; Millett, Molly M.; Nelson, Diana S.; Bornholdt, Zachary A.; Fusco, Marnie L.; Abelson, Dafna M.; Oda, Shun-ichiro; Hartnett, Jessica N.; Rowland, Megan M.; Heinrich, Megan L.; Akdag, Marjan; Goba, Augustine; Momoh, Mambu; Fullah, Mohammed; Baimba, Francis; Gbakie, Michael; Safa, Sadiki; Fonnie, Richard; Kanneh, Lansana; Cross, Robert W.; Geisbert, Joan B.; Geisbert, Thomas W.; Kulakosky, Peter C.; Grant, Donald S.; Shaffer, Jeffery G.; Schieffelin, John S.; Wilson, Russell B.; Saphire, Erica Ollmann; Branco, Luis M.; Garry, Robert F.; Khan, S. Humarr; Pitts, Kelly R.
2015-01-01
Background. Throughout the 2014–2015 Ebola outbreak in West Africa, major gaps were exposed in the availability of validated rapid diagnostic platforms, protective vaccines, and effective therapeutic agents. These gaps potentiated the development of prototype rapid lateral flow immunodiagnostic (LFI) assays that are true point-of-contact platforms, for the detection of active Ebola infections in small blood samples. Methods. Recombinant Ebola and Marburg virus matrix VP40 and glycoprotein (GP) antigens were used to derive a panel of monoclonal and polyclonal antibodies. Antibodies were tested using a multivariate approach to identify antibody-antigen combinations suitable for enzyme-linked immunosorbent assay (ELISA) and LFI assay development. Results. Polyclonal antibodies generated in goats were superior reagents for capture and detection of recombinant VP40 in test sample matrices. These antibodies were optimized for use in antigen-capture ELISA and LFI assay platforms. Prototype immunoglobulin M (IgM)/immunoglobulin G (IgG) ELISAs were similarly developed that specifically detect Ebola virus–specific antibodies in the serum of experimentally infected nonhuman primates and in blood samples obtained from patients with Ebola from Sierra Leone. Conclusions. The prototype recombinant Ebola LFI assays developed in these studies have sensitivities that are useful for clinical diagnosis of acute ebolavirus infections. The antigen-capture and IgM/IgG ELISAs provide additional confirmatory assay platforms for detecting VP40 and other ebolavirus-specific immunoglobulins. PMID:26232440
Detection of squamous carcinoma cells using gold nanoparticles
NASA Astrophysics Data System (ADS)
Dai, Wei-Yun; Lee, Sze-tsen; Hsu, Yih-Chih
2015-03-01
The goal of this study is to use gold nanoparticle as a diagnostic agent to detect human squamous carcinoma cells. Gold nanoparticles were synthesized and the gold nanoparticle size was 34.3 ± 6.2 nm. Based on the over-expression of epidermal growth factor receptor (EGFR) biomarkers in squamous carcinoma cells, we hypothesized that EGFR could be a feasible biomarker with a target moiety for detection. We further modified polyclonal antibodies of EGFR on the surface of gold nanoparticles. We found selected squamous carcinoma cells can be selectively detected using EGFR antibody-modified gold nanoparticles via receptor-mediated endocytosis. Cell death was also examined to determine the survival status of squamous carcinoma cells with respect to gold nanoparticle treatment and EGFR polyclonal antibody modification.
Sotnikov, Dmitriy V; Byzova, Nadezhda A; Zherdev, Anatoly V; Eskendirova, Saule Z; Baltin, Kairat K; Mukanov, Kasim K; Ramankulov, Erlan M; Sadykhov, Elchin G; Dzantiev, Boris B
2015-01-01
An immunochromatographic test system was developed for rapid detection of the levels of specific IgG antibodies to Brucella abortus lipopolysaccharide, as a tool for diagnosis of brucellosis in cattle. The pilot test strips were examined using blood sera from sick (78 samples) and healthy (35 samples) cows. The results obtained by immunochromatographic assay, using a portable optical densitometer for digital video detection, correlate well with the results obtained by immunoenzyme assay and are in agreement with the results of the disease diagnosis. The new test system allows detection of antibodies within 10 min and can be proposed as an alternative to the methods available for serodiagnosis of brucellosis.
Shih, Andrew W; Sheppard, Jo-Ann I; Warkentin, Theodore E
2017-10-05
One of the standard distinctions between type 1 (non-immune) and type 2 (immune-mediated) heparin-induced thrombocytopenia (HIT) is the transience of thrombocytopenia: type 1 HIT is viewed as early-onset and transient thrombocytopenia, with platelet count recovery despite continuing heparin administration. In contrast, type 2 HIT is viewed as later-onset (i. e., 5 days or later) thrombocytopenia in which it is generally believed that platelet count recovery will not occur unless heparin is discontinued. However, older reports of type 2 HIT sometimes did include the unexpected observation that platelet counts could recover despite continued heparin administration, although without information provided regarding changes in HIT antibody levels in association with platelet count recovery. In recent years, some reports of type 2 HIT have confirmed the observation that platelet count recovery can occur despite continuing heparin administration, with serological evidence of waning levels of HIT antibodies ("seroreversion"). We now report two additional patient cases of type 2 HIT with platelet count recovery despite ongoing therapeutic-dose (1 case) or prophylactic-dose (1 case) heparin administration, in which we demonstrate concomitant waning of HIT antibody levels. We further review the literature describing this phenomenon of HIT antibody seroreversion and platelet count recovery despite continuing heparin administration. Our observations add to the concept that HIT represents a remarkably transient immune response, including sometimes even when heparin is continued.
Microtiter plate-based antibody microarrays for bacteria and toxins
USDA-ARS?s Scientific Manuscript database
Research has focused on the development of rapid biosensor-based, high-throughput, and multiplexed detection of pathogenic bacteria in foods. Specifically, antibody microarrays in 96-well microtiter plates have been generated for the purpose of selective detection of Shiga toxin-producing E. coli (...
[Establishment of systemic lupus erythematosus-like murine model with Sm mimotope].
Xie, Hong-Fu; Feng, Hao; Zeng, Hai-Yan; Li, Ji; Shi, Wei; Yi, Mei; Wu, Bin
2007-04-01
To establish systemic lupus erythematosus (SLE) -like murine model by immunizing BALB/C mice with Sm mimotope. Sm mimotope was identified by screening a 12-mer random peptide library with monoclonal anti-Smith antibody. Sm mimotope was initially defined with sandwich ELISA, DNA sequencing, and deduced amino acid sequence; and BALB/C mice were subcutaneously injected with mixture phages clones. Sera Sm antibody, anti-double stranded DNA (dsDNA) antibody, and antinuclear antibody (ANA) of mice were detected using direct immunofluorescence; kidney histological changes were examined by HE staining. Five randomly selected peptides were sequenced and the amino acid sequences IR, SQ, and PP were detected in a higher frequency. High-titer IgG autoantibodies of dsDNA, Sm, and ANA in the sera of experiment group were detected by ELISA 28 days after having been immunized by Sm mimotope. Proteinuria was detected 33 days later; immune complex and nephritis were observed in kidney specimens. SLE-like murine model can be successfully induced by Sm phage mimotope.
Horsington, Jacquelyn; Hartley, Carol A; Gilkerson, James R
2013-09-01
Respiratory infections are a major burden in the performance horse industry. Equine rhinitis B virus (ERBV) has been isolated from horses displaying clinical respiratory disease, and ERBV-neutralizing antibodies have been detected in 50-80% of horses in reported surveys. Current ERBV isolation and detection methods may underestimate the number of ERBV-positive animals and do not identify multiple serotype infections. The aim of the current study was to develop a serotyping ERBV antibody-detection enzyme-linked immunosorbent assay (ELISA) and examine the seroprevalence of ERBV in a group of Australian weanling horses. ELISAs with high sensitivity and specificity were developed. The seroprevalence of ERBV in the weanling horses was high (74-86%); ERBV-3 antibodies were most prevalent (58-62%) and ERBV-2 antibodies were least prevalent (10-16%). Many horses were seropositive to 2 or more serotypes. All 3 serotypes of ERBV were detected, and concurrent positivity to multiple serotypes was common.
Rapid, Sensitive Detection of Botulinum Toxin on a Flexible Microfluidics Platform
DOE Office of Scientific and Technical Information (OSTI.GOV)
Warner, Marvin G.; Dockendorff, Brian P.; Feldhaus, Michael J.
2004-10-30
In this paper we will describe how high affinity reagents and a sensor configuration enabling rapid mass transport can be combined for rapid, sensitive biodetection. The system that we have developed includes a renewable surface immunoassay, which involves on-column detection of a fluorescently labeled secondary antibody in a sandwich immunoassay. Yeast display and directed molecular evolution were used to create high affinity antibodies to the botulinum toxin heavy chain receptor binding domain, AR1 and 3D12. A rotating rod renewable surface microcolumn was used to form a microliter-sized column containing beads functionalized with the capture antibody (AR1). The column was perfusedmore » with sample, wash solutions, and a fluorescently labeled secondary antibody (3D12) while the on-column fluorescence was monitored. Detection was accomplished in less than 5 minutes, with a total processing time of about 10 minutes. On-column detection of botulinum toxin was more sensitive and much faster than flow cytometry analysis on microbeads using the same reagents.« less
Executive working memory load induces inattentional blindness.
Fougnie, Daryl; Marois, René
2007-02-01
When attention is engaged in a task, unexpected events in the visual scene may go undetected, a phenomenon known as inattentional blindness (IB). At what stage of information processing must attention be engaged for IB to occur? Although manipulations that tax visuospatial attention can induce IB, the evidence is more equivocal for tasks that engage attention at late, central stages of information processing. Here, we tested whether IB can be specifically induced by central executive processes. An unexpected visual stimulus was presented during the retention interval of a working memory task that involved either simply maintaining verbal material or rearranging the material into alphabetical order. The unexpected stimulus was more likely to be missed during manipulation than during simple maintenance of the verbal information. Thus, the engagement of executive processes impairs the ability to detect unexpected, task-irrelevant stimuli, suggesting that IB can result from central, amodal stages of processing.
Tesini, Brenda L; Wright, Terry W; Malone, Jane E; Haidaris, Constantine G; Harber, Martha; Sant, Andrea J; Nayak, Jennifer L; Gigliotti, Francis
2017-04-01
Pneumocystis pneumonia (PcP) is a life-threatening infection that affects immunocompromised individuals. Nearly half of all PcP cases occur in those prescribed effective chemoprophylaxis, suggesting that additional preventive methods are needed. To this end, we have identified a unique mouse Pneumocystis surface protein, designated Pneumocystis cross-reactive antigen 1 (Pca1), as a potential vaccine candidate. Mice were immunized with a recombinant fusion protein containing Pca1. Subsequently, CD4 + T cells were depleted, and the mice were exposed to Pneumocystis murina Pca1 immunization completely protected nearly all mice, similar to immunization with whole Pneumocystis organisms. In contrast, all immunized negative-control mice developed PcP. Unexpectedly, Pca1 immunization generated cross-reactive antibody that recognized Pneumocystis jirovecii and Pneumocystis carinii Potential orthologs of Pca1 have been identified in P. jirovecii Such cross-reactivity is rare, and our findings suggest that Pca1 is a conserved antigen and potential vaccine target. The evaluation of Pca1-elicited antibodies in the prevention of PcP in humans deserves further investigation. Copyright © 2017 American Society for Microbiology.
Should we be screening for anti-Js(a)?
Nikolis, Nancy M; Boctor, Fouad; Heaton, William Andrew; Martone, James
2011-01-01
We analyzed our historic patient database at North Shore University Hospital and determined both the overall frequency of anti-Js(a) and the frequency at which it was detected in combination with other alloantibodies to red blood cell (RBC) antigens. Screening cells used currently are negative for Js(a). Our data suggest that anti-Js(a) would not be detected in 30 to 40 percent of patients in which it is the sole antibody present. Since 1996 the antibody was only detected when other antibodies were found in the screening process. We are exposing 1.7 percent of our patients (90 patients/year) to Js(a). The clinical significance of anti-Js(a) is apparent with previous literature, and our conclusion is that additional studies should be performed to determine whether Js(a) should be included in current antibody screening cells.
Utility of HLA Antibody Testing in Kidney Transplantation
Konvalinka, Ana
2015-01-01
HLA antigens are polymorphic proteins expressed on donor kidney allograft endothelium and are critical targets for recipient immune recognition. HLA antibodies are risk factors for acute and chronic rejection and allograft loss. Solid-phase immunoassays for HLA antibody detection represent a major advance in sensitivity and specificity over cell-based methods and are widely used in organ allocation and pretransplant risk assessment. Post-transplant, development of de novo donor–specific HLA antibodies and/or increase in donor-specific antibodies from pretransplant levels are associated with adverse outcomes. Although single antigen bead assays have allowed sensitive detection of recipient HLA antibodies and their specificities, a number of interpretive considerations must be appreciated to understand test results in clinical and research contexts. This review, which is especially relevant for clinicians caring for transplant patients, discusses the technical aspects of single antigen bead assays, emphasizes their quantitative limitations, and explores the utility of HLA antibody testing in identifying and managing important pre- and post-transplant clinical outcomes. PMID:25804279
Magnetic bead-quantum dot assay for detection of a biomarker for traumatic brain injury
NASA Astrophysics Data System (ADS)
Kim, Chloe; Searson, Peter C.
2015-10-01
Current diagnostic methods for traumatic brain injury (TBI), which accounts for 15% of all emergency room visits, are limited to neuroimaging modalities. The challenges of accurate diagnosis and monitoring of TBI have created the need for a simple and sensitive blood test to detect brain-specific biomarkers. Here we report on an assay for detection of S100B, a putative biomarker for TBI, using antibody-conjugated magnetic beads for capture of the protein, and antibody-conjugated quantum dots for optical detection. From Western Blot, we show efficient antigen capture and concentration by the magnetic beads. Using magnetic bead capture and quantum dot detection in serum samples, we show a wide detection range and detection limit below the clinical cut-off level.Current diagnostic methods for traumatic brain injury (TBI), which accounts for 15% of all emergency room visits, are limited to neuroimaging modalities. The challenges of accurate diagnosis and monitoring of TBI have created the need for a simple and sensitive blood test to detect brain-specific biomarkers. Here we report on an assay for detection of S100B, a putative biomarker for TBI, using antibody-conjugated magnetic beads for capture of the protein, and antibody-conjugated quantum dots for optical detection. From Western Blot, we show efficient antigen capture and concentration by the magnetic beads. Using magnetic bead capture and quantum dot detection in serum samples, we show a wide detection range and detection limit below the clinical cut-off level. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr05608j
Gennari, Solange Maria; Pena, Hilda Fátima de Jesus; Lindsay, David Scott; Lopes, Marcos Gomes; Soares, Herbert Sousa; Cabral, Aline Diniz; Vitaliano, Sérgio Netto; Amaku, Marcos
2016-01-01
Sarcocystis neurona and Neospora hughesi are coccidian protozoa that can cause neurological illness in horses in America. In this study we report seroprevalence of Neospora spp. andS. neurona in sera of 333 donkeys from the northeastern region of Brazil. Antibodies to Neospora spp. were detected in 2% (7 donkeys) of 333 sera tested by the indirect fluorescent antibody test (IFAT) with a cut-off dilution of 1:40. Antibodies to S. neurona were found in 3% (10 donkeys) of the samples tested by IFAT (cut-off ≥50) and 21% (69 donkeys) by the direct agglutination test (SAT ≥50). The SAT and IFAT results for S. neurona showed a poor concordance (value of Kappa=0.051). This is the first report of Neospora spp. antibodies in Brazilian donkeys and the first detection of antibodies against S. neurona in this animal species.
Grimprel, E; Bégué, P; Anjak, I; Njamkepo, E; François, P; Guiso, N
1996-01-01
Three hundred sixty children were tested for pertussis serology 0.5 to 1.58 months after complete whole-cell pertussis vaccination. An immunoblot assay was used to detect serum antibodies to pertussis toxin, filamentous hemagglutinin, adenylate cyclase-hemolysin, and pertactin, and agglutination was used for detection of anti-agglutinogen antibodies. Antibodies against pertussis toxin, pertactin, and agglutinogens decreased rapidly after vaccination but increased secondarily, suggesting exposure to infected persons. In contrast, anti-filamentous hemagglutinin antibodies persisted and anti-adenylate cyclase-hemolysin antibodies increased continuously, suggesting either cross-reaction with non-Bordetella antigens or exposure to Bordetella isolates expressing these two antigens, including Bordetella pertussis. These data suggest that unrecognized pertussis is common in France despite massive and sustained immunization in infants and that vaccinated children become susceptible to infection more than 6 years after their last vaccination. PMID:8770511
Ellinger, Isabella; Chatuphonprasert, Waranya; Reiter, Martin; Voss, Agnes; Kemper, Jost; Straka, Elisabeth; Scheinast, Matthias; Zeisler, Harald; Salzer, Hans; Gundacker, Claudia
2016-07-01
While investigating placental mercury transport, we validated specificity of commercial antibodies against four candidate transporters (Large neutral amino acids transporter (LAT)1, LAT2, 4F2 cell-surface antigen heavy chain (4F2hc), and multidrug resistance-associated protein (MRP)2) by immunoblotting and small interfering RNA (siRNA)-mediated protein knockdown. An anti-4F2hc- and one anti-LAT1-antibody were specific. Another anti-LAT1-antibody reacted with LAT2. Two anti-LAT2-antibodies detected mainly albumin in placental lysates. A specific anti-MRP2-antibody hardly detected MRP2 in human placentas, contradicting published data. We recommend testing any unknown antibody by western blotting for 1/specificity for the protein of interest using e.g. siRNA knockdown and 2/cross-reactivity with albumin. Copyright © 2016 Elsevier Ltd. All rights reserved.
Venteo, A; Rebollo, B; Sarraseca, J; Rodriguez, M J; Sanz, A
2012-04-01
Precise and rapid detection of porcine reproductive respiratory syndrome virus (PRRSV) infection in swine farms is critical. Improvement of control procedures, such as testing incoming gilt and surveillance of seronegative herds requires more rapid and sensitive methods. However, standard serological techniques detect mainly IgG antibodies. A double recognition enzyme-linked immunosorbent assay (DR-ELISA) was developed for detection of antibodies specific to European PRRSV. This new assay can recognize both IgM and IgG antibodies to PRSSV which might be useful for detecting in routine surveillance assays pigs that are in the very early stages of infection and missed by conventional assays detecting only IgG antibodies. DR-ELISA is based on the double recognition of antigen by antibody. In this study, the recombinant nucleocapsid protein (N) of PRRSV was used both as the coating and the enzyme-conjugated antigen. To evaluate the sensitivity of the assay at early stages of the infection, sera from 69 pigs infected with PRRSV were collected during successive days post infection (pi) and tested. While standard methods showed low sensitivity rates before day 14 pi, DR-ELISA detected 88.4% seropositive samples at day 7 showing greater sensitivity at early stages of the infection. Further studies were carried out to assess the efficiency of the new assay, and the results showed DR-ELISA to be a sensitive and accurate method for early diagnosis of EU-PRRSV infection. Copyright © 2012 Elsevier B.V. All rights reserved.
IDENTIFICATION OF A SPOROZOITE-SPECIFIC ANTIGEN FROM TOXOPLASMA GONDII
Hill, Dolores; Coss, Cathleen; Dubey, J. P.; Wroblewski, Kristen; Sautter, Mari; Hosten, Tiffany; Muñoz-Zanzi, Claudia; Mui, Ernest; Withers, Shawn; Boyer, Kenneth; Hermes, Gretchen; Coyne, Jessica; Jagdis, Frank; Burnett, Andrew; McLeod, Patrick; Morton, Holmes; Robinson, Donna; McLeod, Rima
2013-01-01
Reduction of risk of human and food animal infection with Toxoplasma gondii is hampered by the lack of epidemiological data documenting the predominant routes of infection (oocyst versus tissue cyst consumption) in horizontally transmitted toxoplasmosis. Existing serological assays can determine previous exposure to the parasite, but not the route of infection. We have used difference gel electrophoresis in combination with tandem mass spectroscopy and Western blot to identify a sporozoite-specific protein (Toxoplasma gondii embryogenesis-related protein, TgERP) which elicited antibody and differentiated oocyst- versus tissue cyst-induced infection in pigs and mice. The recombinant protein was selected from a cDNA library constructed from T. gondii sporozoites, and this protein was used in Western blots and probed with sera from T. gondii infected humans. Serum antibody to TgERP was detected in humans within 6–8 mo of initial oocyst-acquired infection. Of 163 individuals in the acute stage of infection (anti-Toxoplasma IgM detected in sera, or <30 in the IgG avidity test), 103 (63.2%) had detectable antibodies that reacted with TgERP. Of 176 individuals with unknown infection route and in the chronic stage of infection (no anti-Toxoplasma IgM detected in sera, or >30 in the IgG avidity test), antibody to TgERP was detected in 31 (17.6%). None of the 132 uninfected individuals tested had detectable antibody to TgERP. These data suggest that TgERP may be useful in detecting exposure to sporozoites in early Toxoplasma infection and implicates oocysts as the agent of infection. PMID:21506817
High sensitivity detection of bisphenol A using liposome chromatography.
Liu, Xue-Ying; Nakamura, Chikashi; Tanimoto, Itsuro; Miyake, Shiro; Nakamura, Noriyuki; Hirano, Takashi; Miyake, Jun
2006-09-18
An antibody column in tandem with a fluorescent dye entrapped liposome column was developed for highly sensitive detection of an endocrine disruptor, bisphenol A (BPA). Anti-BPA antibody was immobilized in a protein G column with orientation control. A derivative of BPA was conjugated to phospholipase A2 (PLA2). BPA sample solutions mixed with the BPA-PLA2 conjugates were injected on to the anti-BPA antibody column and competitive binding occurred in the antibody column. The amount of the free conjugate was proportional to the concentration of the BPA sample. The eluted conjugates were injected on to the second column gel on which calcein-entrapped liposomes were immobilized and the PLA2-catalyzed hydrolysis of liposomal phospholipids causing fluorescent dye leakage as a signal amplification. In this system, the mixture of BPA and BPA-PLA2 conjugate were incubated for 60 min in the anti-BPA column, and then the collected solution was applied to the liposome column. The BPA detection range of 0.02-140 ng mL(-1) was wider than 0.03-6.6 ng mL(-1) obtained by the method of competitive ELISA using the same antibody. Moreover, this system could be adapted to an HPLC system resulting in almost the same detection limit in online detection. The method could be applied to environmental samples, river water and soil extracts. The BPA concentration of 0.1 ng mL(-1) and 10 ng g(-1) was detectable in water and soil extract, respectively.
Yang, Mei; Wang, Zhuoya; Hao, Wei; Wang, Yanfang; Huang, Li; Cai, Jianpiao; Jiang, Lingxiao; Che, Xiaoyan; Zhong, Xiaozhu; Yu, Nan
2014-05-01
To establish two double-antigen sandwich ELISA systems to detect anti-Afmp1cr and Afmp2cr antibodies of Aspergillus fumigatus. Recombinant Afmp1cr and Afmp2cr proteins of A.fumigatus expressed in Pichia pastoris were obtained. Double-antigen sandwich ELISA systems for detecting specific anti-Afmp1cr and anti-Afmp2cr antibodies were developed after chessboard titrating to determine the appropriate concentrations of the recombinant proteins and HRP-labeled proteins. The sensitivity of the assay was evaluated using serum samples of rabbits immunized with Afmp1cr and Afmp2cr. The specificity of the assay was evaluated by detecting serum samples from healthy donors and patients with other pathogenic fungal and baterial infections. The performance of the two ELISA kits was furthered evaluated using serum samples from patients with suspected Aspergillus infection. The established ELISA kits were capable of detecting anti-Afmp1cr and anti-Afmp2cr antibodies in immunized rabbit serum at the maximum dilutions of 800 and 3200, respectively. No cross-reactivity was observed in detecting serum from patients with other pathogenic fungal or bactetial infections. Both of the two kits yielded positive results in sera from two established Aspergillus-infected cases and a suspected case. Two antibody-capture ELISA kits were developed for the laboratory diagnosis of A.fumigatus infection and can be potentially useful in the clinical diagnosis of Aspergillosis infections.
Kamps, Amanda J; Dubay, Shelli A; Langenberg, Julie; Maes, Roger K
2015-07-01
Blood samples are often collected from free-ranging wildlife for antibody detection. However, filter-paper (FP) strips are more cost efficient and easy to collect and store. We evaluated trapper-collected FP strips and body-cavity blood for canine distemper (CDV) and parvovirus (CPV-2) antibody detection in raccoons (Procyon lotor) and coyotes (Canis latrans). From 2008 to 2010, licensed trappers near Madison and Milwaukee, Wisconsin, US collected paired samples from harvested animals. Canine distemper antibodies were detected using virus neutralization and parvovirus antibodies were detected using hemagglutination inhibition. Titers ≥ 1:32 for CDV and ≥ 1:25 for CPV-2 were considered evidence of exposure. Using Cohen's kappa test of agreement, FP strip titers agreed with sera for CDV in coyotes (n = 28, K = 0.772) and raccoons (n = 29, K = 0.858) and for CPV-2 in coyotes (n = 40, K = 0.775) and raccoons (n = 70, K = 0.646). However, raccoons determined to be exposed to CPV-2 from sera were unexposed by FP strips in 35% of the samples. Titer results may be affected by quality and volume of blood samples, interval between collection and processing, small sample sizes, and diagnostic testing procedures. Filter-paper strips can be useful for detecting CDV and CPV-2 exposure in coyotes and raccoons with correct field sample collection and appropriate diagnostic testing procedures.
Cosmogenic radionuclides on LDEF: An unexpected Be-10 result
NASA Technical Reports Server (NTRS)
Gregory, J. C.; Albrecht, A.; Herzog, G.; Klein, J.; Middleton, R.; Dezfouly-Arjomandy, B.; Harmon, B. A.
1993-01-01
Following the discovery of the atmospheric derived cosmogenic radionuclide Be-7 on the Long Duration Exposure Facility (LDEF), a search began for other known nuclides produced by similar mechanisms. None of the others have the narrow gamma-ray line emission of Be-7 decay which enabled its rapid detection and quantification. A search for Be-10 atoms on LDEF clamp plates using accelerator mass spectrometry is described. An unexpected result was obtained.
Halliwell, R E; Brim, T A; Hines, M T; Wolf, D; White, F H
1985-10-01
An enzyme linked immunosorbent assay was developed for the detection of immunoglobulin class specific antibodies to Leptospira interrogans serovar pomona in the serum and aqueous humor of horses. Serum antibody was also assayed by microscopic agglutination tests. Although higher levels of antibody were found in sera from horses with signs of uveitis, the association was not statistically significant. Antibodies to pomona were detected in the aqueous of 12 eyes from the 101 horses sampled at a slaughterhouse, and in most instances, a comparison of the aqueous/serum antibody level with that of the total aqueous/serum IgG level indicated intraocular antibody synthesis. Antibodies were also found in 4 aqueous (or vitreous) samples out of 9 obtained from horses with clinically documented uveitis and the above comparison again indicated intraocular antibody synthesis. The data point to an important role for pomona as an etiology of equine recurrent uveitis but also emphasize that the initiating cause for this disease is often obscure in that association with leptospirosis cannot be shown in many instances.