Sample records for unicondylar knee prostheses

  1. Revision Rates after Primary Hip and Knee Replacement in England between 2003 and 2006

    PubMed Central

    Sibanda, Nokuthaba; Copley, Lynn P; Lewsey, Jim D; Borroff, Mick; Gregg, Paul; MacGregor, Alex J; Pickford, Martin; Porter, Martyn; Tucker, Keith; van der Meulen, Jan H

    2008-01-01

    Background Hip and knee replacement are some of the most frequently performed surgical procedures in the world. Resurfacing of the hip and unicondylar knee replacement are increasingly being used. There is relatively little evidence on their performance. To study performance of joint replacement in England, we investigated revision rates in the first 3 y after hip or knee replacement according to prosthesis type. Methods and Findings We linked records of the National Joint Registry for England and Wales and the Hospital Episode Statistics for patients with a primary hip or knee replacement in the National Health Service in England between April 2003 and September 2006. Hospital Episode Statistics records of succeeding admissions were used to identify revisions for any reason. 76,576 patients with a primary hip replacement and 80,697 with a primary knee replacement were included (51% of all primary hip and knee replacements done in the English National Health Service). In hip patients, 3-y revision rates were 0.9% (95% confidence interval [CI] 0.8%–1.1%) with cemented, 2.0% (1.7%–2.3%) with cementless, 1.5% (1.1%–2.0% CI) with “hybrid” prostheses, and 2.6% (2.1%–3.1%) with hip resurfacing (p < 0.0001). Revision rates after hip resurfacing were increased especially in women. In knee patients, 3-y revision rates were 1.4% (1.2%–1.5% CI) with cemented, 1.5% (1.1%–2.1% CI) with cementless, and 2.8% (1.8%–4.5% CI) with unicondylar prostheses (p < 0.0001). Revision rates after knee replacement strongly decreased with age. Interpretation Overall, about one in 75 patients needed a revision of their prosthesis within 3 y. On the basis of our data, consideration should be given to using hip resurfacing only in male patients and unicondylar knee replacement only in elderly patients. PMID:18767900

  2. PMMA Third-Body Wear after Unicondylar Knee Arthroplasty Decuples the UHMWPE Wear Particle Generation In Vitro

    PubMed Central

    Paulus, Alexander Christoph; Franke, Manja; Kraxenberger, Michael; Schröder, Christian; Jansson, Volkmar

    2015-01-01

    Introduction. Overlooked polymethylmethacrylate after unicondylar knee arthroplasty can be a potential problem, since this might influence the generated wear particle size and morphology. The aim of this study was the analysis of polyethylene wear in a knee wear simulator for changes in size, morphology, and particle number after the addition of third-bodies. Material and Methods. Fixed bearing unicondylar knee prostheses (UKA) were tested in a knee simulator for 5.0 million cycles. Following bone particles were added for 1.5 million cycles, followed by 1.5 million cycles with PMMA particles. A particle analysis by scanning electron microscopy of the lubricant after the cycles was performed. Size and morphology of the generated wear were characterized. Further, the number of particles per 1 million cycles was calculated for each group. Results. The particles of all groups were similar in size and shape. The number of particles in the PMMA group showed 10-fold higher values than in the bone and control group (PMMA: 10.251 × 1012; bone: 1.145 × 1012; control: 1.804 × 1012). Conclusion. The addition of bone or PMMA particles in terms of a third-body wear results in no change of particle size and morphology. PMMA third-bodies generated tenfold elevated particle numbers. This could favor an early aseptic loosening. PMID:25866795

  3. Knee stability before and after total and unicondylar knee replacement: in vivo kinematic evaluation utilizing navigation.

    PubMed

    Casino, Daniela; Martelli, Sandra; Zaffagnini, Stefano; Lopomo, Nicola; Iacono, Francesco; Bignozzi, Simone; Visani, Andrea; Marcacci, Maurilio

    2009-02-01

    Surgical navigation systems are currently used to guide the surgeon in the correct alignment of the implant. The aim of this study was to expand the use of navigation systems by proposing a surgical protocol for intraoperative kinematics evaluations during knee arthroplasty. The protocol was evaluated on 20 patients, half undergoing unicondylar knee arthroplasty (UKA) and half undergoing posterior-substituting, rotating-platform total knee arthroplasty (TKA). The protocol includes a simple acquisition procedure and an original elaboration methodology. Kinematic tests were performed before and after surgery and included varus/valgus stress at 0 and 30 degrees and passive range of motion. Both UKA and TKA improved varus/valgus stability in extension and preserved the total magnitude of screw-home motion during flexion. Moreover, compared to preoperative conditions, values assumed by tibial axial rotation during flexion in TKA knees were more similar to the rotating patterns of UKA knees. The analysis of the anteroposterior displacement of the knee compartments confirmed that the two prostheses did not produce medial pivoting, but achieved a postoperative normal behavior. These results demonstrated that proposed intraoperative kinematics evaluations by a navigation system provided new information on the functional outcome of the reconstruction useful to restore knee kinematics during surgery.

  4. Revision of Unicondylar to Total Knee Arthroplasty: A Systematic Review

    PubMed Central

    Siddiqui, Nashat A; Ahmad, Zafar M

    2012-01-01

    Isolated unicompartmental osteoarthritis in the young patient is a difficult problem to treat; they may be too young to consider total knee arthroplasty due to difficulties with inevitable future revision. Unicompartmental knee arthroplasty is one possible solution as it is perceived by some as being a smaller surgical insult than total knee arthroplasty, with easier revision to total knee arthroplasty than a revision total knee arthroplasty. A total knee arthroplasty performed as a revision unicondylar knee arthroplasty is thought by some authors to have equivalent functional outcomes to a primary total knee replacement. However, there have been several studies suggesting that revision is not as simple as suggested, and that function is not as good as primary total knee arthroplasty. We performed a systematic review of the literature regarding outcomes after revision of a unicondylar knee arthroplasty. Although there are many studies proposing selective use of the unicondylar knee arthroplasty, there are a number of studies highlighting difficulties with revision and poorer outcomes, and, therefore, the unicondylar knee arthroplasty cannot be considered a small procedure that will 'buy time' for the patient, and have results equal to a primary knee arthroplasty when revised. Further controlled studies, ideally randomised, are required before final conclusions can be drawn. PMID:22905072

  5. Polyethylene damage and deformation on fixed-bearing, non-conforming unicondylar knee replacements corresponding to progressive changes in alignment and fixation.

    PubMed

    Harman, Melinda K; Schmitt, Sabine; Rössing, Sven; Banks, Scott A; Sharf, Hans-Peter; Viceconti, Marco; Hodge, W Andrew

    2010-07-01

    Deviations from nominal alignment of unicondylar knee replacements impact knee biomechanics, including the load and stress distribution at the articular contact surfaces. This study characterizes relationships between the biomechanical environment, distinguished by progressive changes in alignment and fixation, and articular damage and deformation in a consecutive series of retrieved unicondylar knee replacements. Twenty seven fixed-bearing, non-conforming unicondylar knee replacements of one design were retrieved after 2 to 13 years of in vivo function. The in vivo biomechanical environment was characterized by grading component migration measured from full-length radiographs and grading component fixation based on intraoperative manual palpation. Articular damage patterns and linear deformation on the polyethylene inserts were measured using optical photogrammetry and contact point digitization. Articular damage patterns and surface deformation on the explanted polyethylene inserts corresponded to progressive changes in component alignment and fixation. Component migration produced higher deformation rates, whereas loosening contributed to larger damage areas but lower deformation rates. Migration and loosening of the femoral component, but not the tibial component, were factors contributing to large regions of abrasion concentrated on the articular periphery. Classifying component migration and fixation at revision proved useful for distinguishing common biomechanical conditions associated with the varied polyethylene damage patterns and linear deformation for this fixed-bearing, non-conforming design. Pre-clinical evaluations of unicondylar knee replacements that are capable of reproducing variations in clinical alignment and predicting the observed wear mechanisms are necessary to better understand the impact of knee biomechanics and design on unicondylar knee replacement longevity. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  6. Is hydroxyapatite a reliable fixation option in unicompartmental knee arthroplasty? A 5- to 13-year experience with the hydroxyapatite-coated unix prosthesis.

    PubMed

    Epinette, Jean-Alain; Manley, Michael T

    2008-10-01

    Hydroxyapatite-coated unicompartmental knee arthroplasty (UKA) is a debatable approach to unicompartmental knee arthritis because UKA isoften viewed as a short-term solution, at best, fora condition that will eventually require a total knee arthroplasty (TKA). Unicompartmental knee arthroplasty is a more technically demanding procedure than TKA, and appropriate patient selection, careful surgical technique, and correct choice of implant geometry are all critical components to its success. A fundamental issue surrounding UKA is whether hydroxyapatite-coated unicompartmental components can provide a long-term solution to unicondylar arthritis. We address this issue in the current study, which is based on a prospective series of 125 hydroxyapatite-coated Unix knee prostheses implanted consecutively between 1994 and 2002, with a 5-year minimum follow-up and a 13-year maximum follow-up. The results of our study indicate that uncemented hydroxyapatite-coated UKA can be successful in the long term.

  7. Five-Year Survival of 20,946 Unicondylar Knee Replacements and Patient Risk Factors for Failure: An Analysis of German Insurance Data.

    PubMed

    Jeschke, Elke; Gehrke, Thorsten; Günster, Christian; Hassenpflug, Joachim; Malzahn, Jürgen; Niethard, Fritz Uwe; Schräder, Peter; Zacher, Josef; Halder, Andreas

    2016-10-19

    Improvements in implant design and surgical technique of unicondylar knee arthroplasty have led to reduced revision rates, but patient selection seems to be crucial for success of such arthroplasties. The purpose of the present study was to analyze the 5-year implant survival rate of unicondylar knee replacements in Germany and to identify patient factors associated with an increased risk of revision, including >30 comorbid conditions. Using nationwide billing data of the largest German health-care insurance for inpatient hospital treatment, we identified patients who underwent unicondylar knee arthroplasty between 2006 and 2012. Kaplan-Meier survival curves with revision as the end point and log-rank tests were used to evaluate 5-year implant survival. A multivariable Cox regression model was used to determine factors associated with revision. The risk factors of age, sex, diagnosis, comorbidities, type of implant fixation, and hospital volume were analyzed. Hazard ratios (HRs) and 95% confidence intervals (95% CIs) were calculated. During the study period, a total of 20,946 unicondylar knee arthroplasties were included. The number of unicondylar knee arthroplasties per year increased during the study period from 2,527 in 2006 to 4,036 in 2012. The median patient age was 64 years (interquartile range, 56 to 72 years), and 60.4% of patients were female. During the time evaluated, the 1-year revision rate decreased from 14.3% in 2006 to 8.7% in 2011. The 5-year survival rate was 87.8% (95% CI, 87.3% to 88.3%). Significant risk factors (p < 0.05) for unicondylar knee arthroplasty revision were younger age (the HR was 2.93 [95% CI, 2.48 to 3.46] for patient age of <55 years, 1.86 [95% CI, 1.58 to 2.19] for 55 to 64 years, and 1.52 [95% CI, 1.29 to 1.79] for 65 to 74 years; patient age of >74 years was used as the reference); female sex (HR, 1.18 [95% CI, 1.07 to 1.29]); complicated diabetes (HR, 1.47 [95% CI, 1.03 to 2.12]); depression (HR, 1.29 [95% CI, 1.06 to 1.57]); obesity, defined as a body mass index of ≥30 kg/m 2 (HR, 1.13 [95% CI, 1.02 to 1.26]); and low-volume hospitals, denoted as an annual hospital volume of ≤10 cases (HR, 1.60 [95% CI, 1.39 to 1.84]), 11 to 20 cases (HR, 1.47 [95% CI, 1.27 to 1.70]), and 21 to 40 cases (HR, 1.31 [95% CI, 1.14 to 1.51]) (>40 cases was used as the reference). Apart from known risk factors, this study showed a significant negative influence of obesity, depression, and complicated diabetes on the 5-year unicondylar knee replacement survival rate. Surgical indications and preoperative patient counseling should consider these findings. Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.

  8. Investigating the primary stability of the transversal support tibial plateau concept to retain both cruciate ligaments during total knee arthroplasty.

    PubMed

    Nowakowski, Andrej M; Stangel, Melanie; Grupp, Thomas M; Valderrabano, Victor

    2012-09-27

    The important roles of the anterior cruciate ligament regarding knee stability, physiologic kinematics, and proprioception are unquestioned. Thus, various efforts have been made to retain the ACL during total knee arthroplasty (TKA). Neither of the existing solutions to this problem, i.e. bicruciate retaining prostheses and implantation of two unicondylar prostheses, has been successful because of concept-specific problems as well as general difficulties with implant fixation. The new transversal support tibial plateau concept is a prosthesis of two individual joint surfaces reinforced beneath the articular line by joint surface supports and buttressed by a single transversal support. This configuration, which enables retention of both cruciate ligaments, should provide good bone fixation and ensure long-term alignment of the individual joint surfaces. In the current study, four prototypes based on this novel concept were developed and the resulting primary stability was analyzed using adapted load testing. The test set-up, with the model-loading of specially prepared Sawbones® and a sinusoidal oscillating load transmission with 25 000 cycles over 10 increasing load levels, achieved subsidence, which enabled comparison of the four different model variants regarding primary stability in view of bone anchoring. The model variant (TSmobile) that allowed transverse glide of the joint surface supports along the transversal support revealed the largest subsidence. A rigid attachment of the joint surface supports of the transversal support tibial plateau thus appears to offer increased primary stability regarding bone anchoring.

  9. Spontaneous recurrent haemarthrosis following unicompartmental knee arthroplasty and its successful treatment by coil embolisation.

    PubMed

    Maheshwari, R; Kelley, S P; Langkamer, V G; Loveday, E

    2004-10-01

    A case of spontaneous recurrent haemarthrosis of the knee presenting 3 months after the unicondylar knee replacement is described. Femoral arteriography demonstrated hypertrophy of the saphenous branch of descending genicular artery with a prominent vascular blush in the region of posteromedial aspect of the popliteal fossa thought to represent a hypertrophic vascular mass of synovium. Therapeutic embolisation of the saphenous branch of descending genicular artery was performed using three fibred platinum coils with satisfactory clinical results. Since the embolisation, the haemarthrosis has not recurred. To our knowledge, this therapeutic procedure used to treat recurrent haemarthrosis following unicondylar knee arthroplasty has not been previously described in the literature.

  10. Cost-effectiveness of unicondylar versus total knee arthroplasty: a Markov model analysis.

    PubMed

    Peersman, Geert; Jak, Wouter; Vandenlangenbergh, Tom; Jans, Christophe; Cartier, Philippe; Fennema, Peter

    2014-01-01

    Unicondylar knee arthroplasty (UKA) is believed to lead to less morbidity and enhanced functional outcomes when compared with total knee arthroplasty (TKA). Conversely, UKA is also associated with a higher revision risk than TKA. In order to further clarify the key differences between these separate procedures, the current study assessing the cost-effectiveness of UKA versus TKA was undertaken. A state-transition Markov model was developed to compare the cost-effectiveness of UKA versus TKA for unicondylar osteoarthritis using a Belgian payer's perspective. The model was designed to include the possibility of two revision procedures. Model estimates were obtained through literature review and revision rates were based on registry data. Threshold analysis and probabilistic sensitivity analysis were performed to assess the model's robustness. UKA was associated with a cost reduction of €2,807 and a utility gain of 0.04 quality-adjusted life years in comparison with TKA. Analysis determined that the model is sensitive to clinical effectiveness, and that a marginal reduction in the clinical performance of UKA would lead to TKA being the more cost-effective solution. UKA yields clear advantages in terms of costs and marginal advantages in terms of health effects, in comparison with TKA. © 2014 Elsevier B.V. All rights reserved.

  11. Ceramic hemi-unicondylar arthroplasty in an adolescent patient with idiopathic tibial chondrolysis.

    PubMed

    Dombroski, Derek; Garino, Jonathan; Lee, Gwo-Chin

    2009-06-01

    Despite recent advances in cartilage regeneration and restoration procedures, isolated, large, full-thickness cartilage lesions in young patients continue to pose significant challenges to patients and orthopedic surgeons. Treatment options for this difficult problem have traditionally included arthrodesis, osteotomy, osteochondral allograft, and prosthetic reconstruction. We present a case of an adolescent patient with isolated idiopathic lateral tibial chondrolysis treated with a custom ceramic hemi-unicondylar hemiarthroplasty. Preoperatively, a 3-dimensional computed tomography scan of the patient's knee was obtained to begin manufacturing a conforming custom ceramic insert that would articulate between the tibial base plate and the patient's native lateral femoral cartilage. Through a lateral parapatellar approach, the tibial preparation was carried out using the Zimmer M/G unicompartmental knee system (Warsaw, Indiana), and the tibial base plate was cemented into position in the standard fashion. A custom, conforming, prefabricated ceramic insert (CeramTec, Memphis, Tennessee) was then inserted onto the tibial base plate. At 5-year follow-up, this salvage procedure was successful in relieving pain and restoring function in this young patient. There were no signs of implant loosening or lysis. Magnetic resonance imaging of the knee at last follow-up revealed that the cartilage thickness of the patient's lateral femoral condyle remained unchanged. Unicondylar hemiarthroplasty performed in patients with large unipolar lesions in the knee can provide durable and reliable pain relief. Ceramic is a viable material that can be considered for articulation with native cartilage.

  12. Robot-Assisted Medial Compartment Arthroplasty Following Remote Patellectomy: A Case Report

    PubMed Central

    Kouk, Shalen; Kalbian, Irene; Wolfe, Elizabeth; Strickland, Sabrina M

    2018-01-01

    Introduction: Total patellectomies are uncommon procedures that are reserved as salvage treatment for severely comminuted fractures of the patella. Due to the alteration of normal joint mechanics, these patients present later on in life with degenerative cartilage damage to the femorotibial joint and altered extensor mechanism. There are very few reports of unicondylar knee arthroplasties following previous patellectomy and none that specifically address robot-assisted unicompartmental knee arthroplasty. A recent case report by Pang et al. described the use of minimally invasive fixed-bearing unicondylar knee arthroplasty in a patellectomized patient with moderate medial compartment osteoarthritis. Our report details a case with more significant chondral loss along with patellar tendon subluxation. Case Report: This is a case report of a patient with severe medial compartment osteoarthritis after a patellectomy following a motor vehicle collision. After failing conservative treatment, the patient underwent a medial MAKOplasty with complete resolution of arthritic pain. Conclusion: Significant pain relief and improved knee function can be achieved with MAKOPlasty partial knee resurfacing system in a previously patellectomized patient with severe medial compartment osteoarthritis. PMID:29854684

  13. [Modern unicondylar knee arthroplasty. Tips and tricks].

    PubMed

    von Knoch, F; Munzinger, U

    2014-05-01

    Unicondylar knee arthroplasty (UKA) is an established therapeutic option for advanced medial or lateral gonarthrosis. The cornerstones of a successful UKA, careful patient selection, preoperative planning and precise operation technique, are discussed in this overview article. In contrast to total knee arthroplasty, UKA allows preservation of the contralateral and patellofemoral compartments as well as the cruciate ligaments and is often associated with rapid postoperative recovery, improved knee kinematics and knee function. However, UKA is technically very demanding. High revision rates have been reported in particular with widespread application, according to national joint replacement registries. Successful UKA relies on meticulous patient selection, preoperative planning and surgical technique. It is justified to broaden classic UKA indications. In medial and lateral UKA three types of mechanical varus-valgus deformity can be encountered: type 1 (isolated intraarticular deformity), type 2 (pronounced deformity due to extraarticular varus deformity in medial UKA or valgus deformity in lateral UKA), type 3 (reduced deformity due to extraarticular valgus deformity in medial UKA or varus deformity in lateral UKA). We believe these deformities should be addressed accordingly with surgical technique.

  14. Medial Unicondylar Knee Arthroplasty Improves Patellofemoral Congruence: a Possible Mechanistic Explanation for Poor Association Between Patellofemoral Degeneration and Clinical Outcome.

    PubMed

    Thein, Ran; Zuiderbaan, Hendrik A; Khamaisy, Saker; Nawabi, Danyal H; Poultsides, Lazaros A; Pearle, Andrew D

    2015-11-01

    The purpose was to determine the effect of medial fixed bearing unicondylar knee arthroplasty (UKA) on postoperative patellofemoral joint (PFJ) congruence and analyze the relationship of preoperative PFJ degeneration on clinical outcome. We retrospectively reviewed 110 patients (113 knees) who underwent medial UKA. Radiographs were evaluated to ascertain PFJ degenerative changes and congruence. Clinical outcomes were assessed preoperatively and postoperatively. The postoperative absolute patellar congruence angle (10.05 ± 10.28) was significantly improved compared with the preoperative value (14.23 ± 11.22) (P = 0.0038). No correlation was found between preoperative PFJ congruence or degeneration severity, and WOMAC scores at two-year follow up. Pre-operative PFJ congruence and degenerative changes do not affect UKA clinical outcomes. This finding may be explained by the post-op PFJ congruence improvement. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Unicondylar arthroplasty in knees with deficient anterior cruciate ligaments.

    PubMed

    Engh, Gerard A; Ammeen, Deborah J

    2014-01-01

    Historically, a functional ACL has been a prerequisite for patients undergoing unicondylar knee arthroplasty (UKA). However, this premise has not been rigorously tested. We compared (1) the survivorship free from revision and (2) the failure mechanisms of UKAs in ACL-deficient knees and UKAs in ACL-intact knees performed over the same time interval. Between November 2000 and July 2008, a fixed bearing UKA was performed in 72 patients (81 knees) with intraoperatively confirmed ACL deficiency. Five patients (five knees) with preoperative instability underwent ACL reconstruction and were excluded from analysis. Of the remaining 67 patients (76 knees) without preoperative instability, implant status was known for 68 UKAs in 60 patients. Survivorship and failure mechanisms for these knees were compared to those of 706 UKAs in ACL-intact knees performed during the same time interval by the same surgeon using the same implant system. Minimum followup for the ACL-deficient group was 2.9 years (mean, 6 years; range, 2.9-10 years). Revision rates between UKAs with and without intact ACLs were similar in the absence of clinical instability (p = 0.58). Six-year UKA survivorship was 94% (95% CI: 88%-100%) in ACL-deficient knees and 93% (95% CI: 91%-96%) in ACL-intact knees (p = 0.89). Five knees (7%) in the ACL-deficient group were revised: disease progression (two), loose tibia (one), persistent pain (one), and revised elsewhere/reason unknown (one). Thirty-six knees in the ACL-intact group underwent revision (5%): aseptic loosening (13), revised elsewhere/reason unknown (11), disease progression (three), tibial subsidence/fracture (four), infection (three), pain (one), and lateral compartment overload (one). At 6 years, deficiency of the ACL in patients without clinical knee instability did not impact the survivorship of UKAs compared to UKAs performed in knees with intact ACLs.

  16. Quality of outcome data in knee arthroplasty

    PubMed Central

    Pabinger, Christof; Lumenta, David Benjamin; Cupak, Daniel; Berghold, Andrea; Boehler, Nikolaus; Labek, Gerold

    2015-01-01

    Background and purpose Recent reports on developer bias in unicondylar knee arthroplasty led to concerns about quality of publications regarding knee implants. We therefore compared revision rates of registry and non-registry studies from the beginning of knee arthroplasty up to the present. We assessed the time interval between market introduction of an implant and emergence of reliable data in non-registry studies. Material and methods We systematically reviewed registry studies (n = 6) and non-registry studies (n = 241) on knee arthroplasty published in indexed, peer-reviewed international scientific journals. The main outcome measure was revision rate per 100 observed component years. Results and interpretation For 82% of the 34 knee implants assessed, revision data from non-registry studies are either absent or poor. 91% of all studies were published in the second and third decade after market introduction. Only 5% of all studies and 1% of all revisions were published in the first decade. The first publications on revision rates of total knee arthroplasty (TKA) started 6 years after market introduction, and reliable data were found from year 12 onward in non-registry studies. However, in unicondylar knee arthroplasty (UKA) the first publications on revision rates could be found first 13 years after market introduction. Revision rates of TKA from non-registry studies were reliable after year 12 following market introduction. UKA revision rates remained below the threshold of registry indices, and failed to demonstrate adjustment towards registries. Thus, the superiority of registry data over non-registry data regarding outcome measurement was validated. PMID:25191934

  17. Knee Extensor Strength and Gait Characteristics After Minimally Invasive Unicondylar Knee Arthroplasty vs Minimally Invasive Total Knee Arthroplasty: A Nonrandomized Controlled Trial.

    PubMed

    Braito, Matthias; Giesinger, Johannes M; Fischler, Stefan; Koller, Arnold; Niederseer, David; Liebensteiner, Michael C

    2016-08-01

    In light of the existing lack of evidence, it was the aim of this study to compare gait characteristics and knee extensor strength after medial unicondylar knee arthroplasty (MUKA) with those after total knee arthroplasty (TKA), given the same standardized minimally invasive surgery (MIS) approach in both groups. Patients scheduled for MIS-MUKA or MIS-TKA as part of clinical routine were invited to participate. A posterior cruciate ligament-retaining total knee design was used for all MIS-TKA. A 3-dimensional gait analysis was performed preoperatively with a VICON system and at 8 weeks postoperative to determine temporospatial parameters, ground reaction forces, joint angles, and joint moments. At the same 2 times, isokinetic tests were performed to obtain peak values of knee extensor torque. A multivariate analysis of variance was conducted and included the main effects time (before and after surgery) and surgical group and the group-by-time interaction effect. Fifteen MIS-MUKA patients and 17 MIS-TKA patients were eligible for the final analysis. The groups showed no differences regarding age, body mass index, sex, side treated, or stage of osteoarthritis. We determined neither intergroup differences nor time × group interactions for peak knee extensor torque or any gait parameters (temporospatial, ground reaction forces, joint angles, and joint moments). It is concluded that MUKA is not superior to TKA with regard to knee extensor strength or 3-dimensional gait characteristics at 8 weeks after operation. As gait characteristics and knee extensor strength are only 2 of the various potential outcome parameters (knee scores, activity scores…) and quadriceps strength might take a longer time to recover, our findings should be interpreted with caution. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  18. Comparison of the primary stability of different tibial baseplate concepts to retain both cruciate ligaments during total knee arthroplasty.

    PubMed

    Nowakowski, Andrej M; Stangel, Melanie; Grupp, Thomas M; Valderrabano, Victor

    2013-10-01

    A novel tibial baseplate design (Transversal Support Tibial Plateau) as a new treatment concept for bi-cruciate retaining total knee arthroplasty is evaluated for mechanical stability and compared to other tibial baseplate designs. This concept should provide better primary stability and thus, less subsidence, than implantation of two separate unicondylar tibial baseplates. Different baseplates were implanted into synthetic bone specimens (Sawbones® Pacific Research Laboratories, Inc., Washington, USA), all uncemented. Using a standardized experimental setup, subsidence was achieved, enabling comparison of the models regarding primary stability. Overall implant subsidence was significantly increased for the two separate unicondylar tibial baseplates versus the new Transversal Support Tibial Plateau concept, which showed comparable levels to a conventional tibial baseplate. Reduced subsidence results in better primary stability. Linking of two separate baseplates appears to provide increased primary stability in terms of bony fixation, comparable to that of a conventional single tibial baseplate. © 2013. Published by Elsevier Ltd. All rights reserved.

  19. [Total Joint Replacement and Return to Sports].

    PubMed

    Oehler, N; Schmidt, T; Niemeier, A

    2016-12-01

    Background: An increasing number of physically active patients not only need to know if they will basically be able to engage in sports after undergoing arthroplasty. They also would like to know whether or not they will be able to resume their preoperative activity levels. This article aims to provide an overview of recent data regarding the following questions on hip, knee and shoulder arthroplasty: (1) What is the impact of physical activity on an endoprosthesis? (2) What level of sports can be achieved after an arthroplasty procedure? (3) What types of sport are recommended for patients with an endoprosthesis? Methods: PubMed-based review of the literature. Narrative review focusing on current data from the years 2010 to 2016. Results: The commonly known recommendation to exercise low-impact sports such as hiking, swimming, cycling or golf at a moderate intensity remains valid for all types of prostheses in all joints. There is broad consensus that the benefits of these sports outweigh the negative effects. Having undergone total hip or knee arthroplasty, most patients with a high preoperative activity level return to sports after 3-6 months, albeit with a clear tendency to lower intensity and a shift from high-impact to low-impact sports. Some key questions have to be answered regarding the effects of low-impact sports that are exercised with high intensity, the effects resulting from high-impact sports, effects specific to different types of sport, and possibilities provided by different prosthesis types. In this context, a lot remains to be done to investigate the limits between positive and negative effects resulting from physical activity of varying intensity. New data suggests that generally a higher physical performance level may be achieved than has been traditionally recommended. Early results of unicondylar knee prostheses are far better than those achieved with bicondylar prostheses. In contrast to expert recommendations, shoulder endoprostheses show the highest postoperative activity levels after inverted arthroplasty, followed by anatomic arthroplasty, and the lowest activity level after the implantation of a hemiprosthesis. Conclusion: There is a significant discrepancy between previous expert recommendations and the actual activity levels that may be achieved after the implantation of a joint prosthesis. Future studies have to define the sports level, the type of sports and the type of prosthesis that provide a positive benefit-risk ratio using state-of-the-art low-abrasion bearing surfaces and prosthesis designs. © Georg Thieme Verlag KG Stuttgart · New York.

  20. [Indications and Borderline Indications for Medial Mobile Bearing Unicondylar Knee Replacement].

    PubMed

    Walker, T; Streit, M R; Streit, J; Gotterbarm, T; Aldinger, P R

    2015-10-01

    Beside the possibility of bicondylar knee replacement, patients with isolated anteromedial osteoarthritis also have the possibility of unicondylar knee replacement. Therefore some requirements are essential such as functionally intact cruciate and collateral ligaments, intact cartilage in the lateral compartment and an intraoperative flexion of more than 100°. An instability or contracture of the cruciate or collateral ligaments, a varus deformity more than 15°, a flexion deformity of more than 15°, an intraoperative flexion less than 100° as well as failed upper tibial osteotomy are seen as contraindications. In addition, a rheumatoid arthritis and a full thickness cartilage defect in the central part of the lateral compartment are seen as a contraindication because of the risk of a progression of the disease. With respect to these contraindications, excellent functional outcome and survival rates could be demonstrated in the long term. An expansion of these criteria, especially in patients with an insufficiency of the cruciate ligaments or after failed upper tibial osteotomy should only be done in certain cases after careful assessment of the benefits and risks. These patients should be informed about the lack of long-term results and the higher risk of complications. Quite commonly, the criteria of Kozinn and Scott are used for patient selection. These criteria were originally established for fixed-bearing prosthesis and have no relevance on mobile-bearing prosthesis. Criteria such as age, level of activity, weight, chondrocalcinosis and anterior knee pain have no effect on the clinical outcome or the long-term survival of a mobile-bearing prosthesis. Georg Thieme Verlag KG Stuttgart · New York.

  1. International comparative evaluation of knee replacement with fixed or mobile-bearing posterior-stabilized prostheses.

    PubMed

    Graves, Stephen; Sedrakyan, Art; Baste, Valborg; Gioe, Terence J; Namba, Robert; Martínez Cruz, Olga; Stea, Susanna; Paxton, Elizabeth; Banerjee, Samprit; Isaacs, Abby J; Robertsson, Otto

    2014-12-17

    Posterior-stabilized total knee prostheses were introduced to address instability secondary to loss of posterior cruciate ligament function, and they have either fixed or mobile bearings. Mobile bearings were developed to improve the function and longevity of total knee prostheses. In this study, the International Consortium of Orthopaedic Registries used a distributed health data network to study a large cohort of posterior-stabilized prostheses to determine if the outcome of a posterior-stabilized total knee prosthesis differs depending on whether it has a fixed or mobile-bearing design. Aggregated registry data were collected with a distributed health data network that was developed by the International Consortium of Orthopaedic Registries to reduce barriers to participation (e.g., security, proprietary, legal, and privacy issues) that have the potential to occur with the alternate centralized data warehouse approach. A distributed health data network is a decentralized model that allows secure storage and analysis of data from different registries. Each registry provided data on mobile and fixed-bearing posterior-stabilized prostheses implanted between 2001 and 2010. Only prostheses associated with primary total knee arthroplasties performed for the treatment of osteoarthritis were included. Prostheses with all types of fixation were included except for those with the rarely used reverse hybrid (cementless tibial and cemented femoral components) fixation. The use of patellar resurfacing was reported. The outcome of interest was time to first revision (for any reason). Multivariate meta-analysis was performed with linear mixed models with survival probability as the unit of analysis. This study includes 137,616 posterior-stabilized knee prostheses; 62% were in female patients, and 17.6% had a mobile bearing. The results of the fixed-effects model indicate that in the first year the mobile-bearing posterior-stabilized prostheses had a significantly higher hazard ratio (1.86) than did the fixed-bearing posterior-stabilized prostheses (95% confidence interval, 1.28 to 2.7; p = 0.001). For all other time intervals, the mobile-bearing posterior-stabilized prostheses had higher hazard ratios; however, these differences were not significant. Mobile-bearing posterior-stabilized prostheses had an increased rate of revision compared with fixed-bearing posterior-stabilized prostheses. This difference was evident in the first year. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

  2. Effect of alignment changes on socket reaction moments during gait in transfemoral and knee-disarticulation prostheses: case series.

    PubMed

    Kobayashi, Toshiki; Orendurff, Michael S; Boone, David A

    2013-09-27

    The alignment of a lower-limb prosthesis is critical to the successful prosthetic fitting and utilization by the wearer. Loads generated by the socket applied to the residual limb while walking are thought to be different in transfemoral and knee-disarticulation prostheses. The aim of this case series was to compare the socket reaction moments between transfemoral and knee-disarticulation prostheses and to investigate the effect of alignment changes on them. Two amputees, one with a transfemoral prosthesis and another with a knee-disarticulation prosthesis, participated in this study. A Smart Pyramid™ was used to measure socket reaction moments while walking under 9 selected alignment conditions; including nominally aligned, angle malalignments of 6° (flexion, extension, abduction and adduction) and translation malalignments of 15 mm (anterior, posterior, medial and lateral) of the socket relative to the foot. This study found that the pattern of the socket reaction moments was similar between transfemoral and knee-disarticulation prostheses. An extension moment in the sagittal plane and a varus moment in the coronal plane were dominant during stance under the nominally aligned condition. This study also demonstrated that alignment changes might have consistent effects on the socket reaction moments in transfemoral and knee-disarticulation prostheses. Extension and posterior translation of the socket resulted in increases in an extension moment, while abduction and lateral translation of the socket resulted in increases in a varus moment. The socket reaction moments may potentially serve as useful biomechanical parameters to evaluate alignment in transfemoral and knee-disarticulation prostheses. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Accuracy of estimating Unicondylar Knee Replacement implant varus/valgus angles from antero-posterior radiographs.

    PubMed

    Khare, Rahul; Jaramaz, Branislav

    2016-12-01

    Unicondylar Knee Replacement (UKR) is an orthopedic surgical procedure to reduce pain and improve function in the knee. Load-bearing long-standing antero-posterior (AP) radiographs are typically used postoperatively to measure the leg alignment and assess the varus/valgus implant orientation. However, implant out-of-plane rotations, user variability, and X-ray acquisition parameters introduce errors in the estimation of the implant varus/valgus estimation. Previous work has explored the accuracy of various imaging modalities in this estimation. In this work, we explored the impact of out-of-plane rotations and X-ray acquisition parameters on the estimation of implant component varus/valgus angles. For our study, we used a single CT scan and positioned femoral and tibial implants under varying orientations within the CT volume. Then, a custom software application was used to obtain digitally reconstructed radiographs from the CT scan with implants under varying orientations. Two users were then asked to manually estimate the varus/valgus angles for the implants. We found that there was significant inter-user variability (p < 0.05) in the varus/valgus estimates for the two users. However, the 'ideal' measurements, obtained using actual implant orientations, showed small errors due to variations in implant orientation. We also found that variation in the projection center does not have a statistically significant impact (p < 0.01) on the estimation of implant varus/valgus angles. We conclude that manual estimates of UKR implant varus/valgus orientations are unreliable.

  4. Design and energetic evaluation of a prosthetic knee joint actuator with a lockable parallel spring.

    PubMed

    Geeroms, J; Flynn, L; Jimenez-Fabian, R; Vanderborght, B; Lefeber, D

    2017-02-03

    There are disadvantages to existing damping knee prostheses which cause an asymmetric gait and higher metabolic cost during level walking compared to non-amputees. Most existing active knee prostheses which could benefit the amputees use a significant amount of energy and require a considerable motor. In this work, a novel semi-active actuator with a lockable parallel spring for a prosthetic knee joint has been developed and tested. This actuator is able to provide an approximation of the behavior of a healthy knee during most of the gait cycle of level walking. This actuator is expanded with a series-elastic actuator to mimic the full gait cycle and enable its use in other functional tasks like stair climbing and sit-to-stance. The proposed novel actuator reduces the energy consumption for the same trajectory with respect to a compliant or directly-driven prosthetic active knee joint and improves the approximation of healthy knee behavior during level walking compared to passive or variable damping knee prostheses.

  5. A Powered Prosthetic Intervention for Bilateral Transfemoral Amputees

    PubMed Central

    Lawson, Brian E.; Ruhe, Brian; Shultz, Amanda; Goldfarb, Michael

    2014-01-01

    This paper presents the design and validation of a control system for a pair of powered knee and ankle prostheses to be used as a prosthetic intervention for bilateral transfemoral amputees. The control system leverages communication between the prostheses for enhanced awareness and stability, along with power generation at the knee and ankle joints to better restore biomechanical functionality in level ground walking. The control methodology employed is a combination of an impedance-based framework for weight-bearing portions of gait and a trajectory-based approach for the non-weight-bearing portions. The control system was implemented on a pair of self-contained powered knee and ankle prostheses, and the ability of the prostheses and control approach to provide walking functionality was assessed in a set of experimental trials with a bilateral transfemoral amputee subject. Specifically, experimental data from these trials indicate that the powered prostheses and bilateral control architecture provide gait kinematics that reproduce healthy gait kinematics to a greater extent than the subject’s daily-use passive prostheses. PMID:25014950

  6. Comparison of in vivo polyethylene wear particles between mobile- and fixed-bearing TKA in the same patients.

    PubMed

    Minoda, Yukihide; Hata, Kanako; Ikebuchi, Mitsuhiko; Mizokawa, Shigekazu; Ohta, Yoichi; Nakamura, Hiroaki

    2017-09-01

    Polyethylene wear particle generation is one of the most important factors that affects the mid- to long-term results of total knee arthroplasties (TKA). Mobile-bearing total knee prostheses were developed to reduce polyethylene wear generation. However, whether mobile-bearing prostheses actually generate fewer polyethylene wear particles than fixed-bearing prostheses remains controversial. The aim of this study was to compare, within individual patients, the in vivo polyethylene wear particles created by a newly introduced mobile-bearing prosthesis in one knee and a conventional fixed-bearing prosthesis in other knee. Eighteen patients receiving bilateral TKAs to treat osteoarthritis were included. The synovial fluid was obtained from 36 knees at an average of 3.5 years after the operation. The in vivo polyethylene wear particles were isolated from the synovial fluid using a previously validated method and examined using a scanning electron microscope and an image analyser. The size and shape of the polyethylene wear particles from the mobile-bearing prostheses were similar to those from the conventional fixed-bearing prostheses. Although the number of wear particles from the mobile-bearing prosthesis (1.63 × 10 7  counts/knee) appeared smaller than that from the fixed-bearing prosthesis (2.16 × 10 7  counts/knee), the difference was not statistically significant. The current in vivo study shows that no statistically significant differences were found between the polyethylene wear particles generated by a newly introduced mobile-bearing PS prosthesis and a conventional fixed-bearing PS prosthesis during the early clinical stage after implantation. Therapeutic study, Level III.

  7. Preservation of kinematics with posterior cruciate-, bicruciate- and patient-specific bicruciate-retaining prostheses in total knee arthroplasty by using computational simulation with normal knee model

    PubMed Central

    Koh, Y-G.; Son, J.; Kwon, S-K.; Kim, H-J.; Kang, K-T.

    2017-01-01

    Objectives Preservation of both anterior and posterior cruciate ligaments in total knee arthroplasty (TKA) can lead to near-normal post-operative joint mechanics and improved knee function. We hypothesised that a patient-specific bicruciate-retaining prosthesis preserves near-normal kinematics better than standard off-the-shelf posterior cruciate-retaining and bicruciate-retaining prostheses in TKA. Methods We developed the validated models to evaluate the post-operative kinematics in patient-specific bicruciate-retaining, standard off-the-shelf bicruciate-retaining and posterior cruciate-retaining TKA under gait and deep knee bend loading conditions using numerical simulation. Results Tibial posterior translation and internal rotation in patient-specific bicruciate-retaining prostheses preserved near-normal kinematics better than other standard off-the-shelf prostheses under gait loading conditions. Differences from normal kinematics were minimised for femoral rollback and internal-external rotation in patient-specific bicruciate-retaining, followed by standard off-the-shelf bicruciate-retaining and posterior cruciate-retaining TKA under deep knee bend loading conditions. Moreover, the standard off-the-shelf posterior cruciate-retaining TKA in this study showed the most abnormal performance in kinematics under gait and deep knee bend loading conditions, whereas patient-specific bicruciate-retaining TKA led to near-normal kinematics. Conclusion This study showed that restoration of the normal geometry of the knee joint in patient-specific bicruciate-retaining TKA and preservation of the anterior cruciate ligament can lead to improvement in kinematics compared with the standard off-the-shelf posterior cruciate-retaining and bicruciate-retaining TKA. Cite this article: Y-G. Koh, J. Son, S-K. Kwon, H-J. Kim, O-R. Kwon, K-T. Kang. Preservation of kinematics with posterior cruciate-, bicruciate- and patient-specific bicruciate-retaining prostheses in total knee arthroplasty by using computational simulation with normal knee model. Bone Joint Res 2017;6:557–565. DOI: 10.1302/2046-3758.69.BJR-2016-0250.R1. PMID:28947604

  8. Large tibial geode, which developed several years after a left medial Oxford unicondylar knee arthroplasty, treated with curettage and bone grafting.

    PubMed

    Curran, Matthew K; Murray, James R

    2018-05-14

    Tibial geodes are rare, and usually reported in association with rheumatoid arthritis. This case study reported the rare occurrence of a tibial geode in association with a left unicondylar knee arthroplasty (UKA). The patient, a 55-year-old male, was initially pleased with his UKA, which was performed at another institution. However, just over one year after the operation he began experiencing pain and discomfort. He did not present to the current institution until he was six years after UKA. This pain was movement and weight bearing related, although he still managed to maintain an active lifestyle working as a builder. After several years of follow-up, a computed tomography (CT) scan showed a significant increase in size of the geode. The patient initially did not want to undergo further surgery, as he was self-employed, but it was decided, in conjunction with the patient, that it was time to operate because the stability of the prothesis was in question. Transcortical and retrograde curettage of the geode was performed and one and a half femoral head allografts were used to fill the geode. Follow-up since the operation showed good infilling of the geode and bone remodelling, with resolution of symptoms at 12 months. This case report was the first to report a symptomatic tibial geode in close association with UKA, which did not lead to revision surgery to total knee arthroplasty (TKA), but instead was successfully treated with currettage and bone grafting. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Tibial rotation kinematics subsequent to knee arthroplasty

    PubMed Central

    Collins, Duane J.; Khatib, Yasser H.; Parker, David A.; Jenkin, Deanne E.; Molnar, Robert B.

    2015-01-01

    Background The use of computer assisted joint replacement has facilitated precise intraoperative measurement of knee kinematics. The changes in “screw home mechanism” (SHM) resulting from Total Knee Arthroplasty (TKA) with different prostheses and constraints has not yet been accurately described. Methods A pilot study was first completed. Intraoperative kinematic data was collected two groups of 15 patients receiving different prostheses. Results On average, patients lost 5.3° of ER (SD = 6.1°). There was no significant difference between the prostheses or different prosthetic constraints. Conclusions There significant loss of SHM after TKA. Further research is required to understand its impact on patient function. PMID:25829754

  10. Wear Distribution Detection of Knee Joint Prostheses by Means of 3D Optical Scanners

    PubMed Central

    Affatato, Saverio; Valigi, Maria Cristina; Logozzo, Silvia

    2017-01-01

    The objective of this study was to examine total knee polyethylene inserts from in vitro simulation to evaluate and display—using a 3D optical scanner—wear patterns and wear rates of inserts exposed to wear by means of simulators. Various sets of tibial inserts have been reconstructed by using optical scanners. With this in mind, the wear behavior of fixed and mobile bearing polyethylene knee configurations was investigated using a knee wear joint simulator. After the completion of the wear test, the polyethylene menisci were analyzed by an innovative 3D optical scanners in order to evaluate the 3D wear distribution on the prosthesis surface. This study implemented a new procedure for evaluating polyethylene bearings of joint prostheses obtained after in vitro wear tests and the proposed new approach allowed quantification of the contact zone on the geometry of total knee prostheses. The results of the present study showed that mobile TKPs (total knee prosthesis) have lower wear resistance with respect to fixed TKPs. PMID:28772725

  11. Tissue sparing surgery in knee reconstruction: unicompartmental (UKA), patellofemoral (PFA), UKA + PFA, bi-unicompartmental (Bi-UKA) arthroplasties

    PubMed Central

    Manzotti, A.; Montironi, F.; Pullen, C.

    2008-01-01

    Recently mini-invasive joint replacement has become one of the hottest topics in the orthopaedic world. However, these terms have been improperly misunderstood as a “key-hole” surgery where traditional components are implanted with shorter surgical approaches, with few benefits and several possible dangers. Small implants as unicompartmental knee prostheses, patellofemoral prostheses and bi-unicompartmental knee prostheses might represent real less invasive procedures: Tissue sparing surgery, the Italian way to minimally invasive surgery (MIS). According to their experience the authors go through this real tissue sparing surgery not limited only to a small incision, but where the surgeons can respect the physiological joint biomechanics. PMID:19384616

  12. Effects of tibial slope changes in the stability of fixed bearing medial unicompartmental arthroplasty in anterior cruciate ligament deficient knees.

    PubMed

    Suero, Eduardo M; Citak, Musa; Cross, Michael B; Bosscher, Marianne R F; Ranawat, Anil S; Pearle, Andrew D

    2012-08-01

    Patients with anterior cruciate ligament (ACL) deficiency may have increased failure rates with UKA as a result of abnormal contact stresses and altered knee kinematics. Variations in the slope of the tibial component in UKA may alter tibiofemoral translation, and affect outcomes. This cadaveric study evaluated tibiofemoral translation during the Lachman and pivot shift tests after changing the slope of a fixed bearing unicondylar tibial component. Sectioning the ACL increased tibiofemoral translation in both the Lachman and pivot shift tests (P<0.05). Tibial slope leveling (decreasing the posterior slope) of the polyethylene insert in a UKA decreases anteroposterior tibiofemoral translation in the sagittal plane to a magnitude similar to that of the intact knee. With 8° of tibial slope leveling, anterior tibial translation during the Lachman test decreased by approximately 5mm. However, no variation in slope altered the pivot shift kinematics in the ACL deficient knees. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. The Influence Of Component Alignment On The Life Of Total Knee Prostheses

    NASA Astrophysics Data System (ADS)

    Bugariu, Delia; Bereteu, Liviu

    2012-12-01

    An arthritic knee affects the patient's life by causing pain and limiting movement. If the cartilage and the bone surfaces are severely affected, the natural joint is replaced with an artificial joint. The procedure is called total knee arthroplasty (TKA). Lately, the numbers of implanted total knee prostheses grow steadily. An important factor in TKA is the perfect alignment of the total knee prosthesis (TKP) components. Component misalignment can lead to the prosthesis loss by producing wear particles. The paper proposes a study on mechanical behaviors of a TKP based on numerical analysis, using ANSYS software. The numerical analysis is based on both the normal and the changed angle of the components alignment.

  14. The role of synovial fluid analysis in the detection of periprosthetic hip and knee infections: a systematic review and meta-analysis.

    PubMed

    De Fine, Marcello; Giavaresi, Gianluca; Fini, Milena; Illuminati, Andrea; Terrando, Silvio; Pignatti, Giovanni

    2018-05-01

    This study tried to ascertain (1) the accuracy of synovial fluid white blood cell count and polymorphonucleate percentage in the diagnosis of periprosthetic hip and knee infections, (2) which test yielded superior test performance, and (3) the influence on diagnostic accuracy of study characteristics such as patient number, study design, study level, anatomic site, and threshold value. A systematic search was conducted including papers assessing more effective cutoffs for synovial fluid tests, having comparative design, evaluating an exclusive cohort of hip or knee prostheses, including a clear definition of infected cases, and reporting sufficient data for the calculation of true-positive, false-positive, false-negative, and true-negative. A total of 375 articles were collected and, given the inclusion criteria, ten manuscripts were included. These studies assessed 1155 hip prostheses (276 infected cases) and 1235 knee prostheses (401 infected cases). The specificity of synovial fluid white blood cell count was significantly increased by using the threshold value ≥ 3000 cell/μL (p = 0.006); the sensitivity of polymorphonucleate percentage was significantly higher in detecting knee infections (p = 0.034). Both tests had a high specificity and sensitivity in detecting periprosthetic joint infections, and no clear superiority of one over the other existed. Furthermore, cutoff and anatomic site significantly influenced synovial fluid white blood cell count and polymorphonucleate percentage, respectively. Synovial fluid analysis is adequate in differentiating patients with periprosthetic hip and knee infections. Our data confirms international guidelines suggesting the use of 3000 cell/μL as cutoff threshold for synovial fluid white blood cell count. Since an anatomic site effect has been demonstrated, the goal of future studies will be to identify different cutoffs for hip and knee prostheses.

  15. An economic model to evaluate cost-effectiveness of computer assisted knee replacement surgery in Norway.

    PubMed

    Gøthesen, Øystein; Slover, James; Havelin, Leif; Askildsen, Jan Erik; Malchau, Henrik; Furnes, Ove

    2013-07-06

    The use of Computer Assisted Surgery (CAS) for knee replacements is intended to improve the alignment of knee prostheses in order to reduce the number of revision operations. Is the cost effectiveness of computer assisted surgery influenced by patient volume and age? By employing a Markov model, we analysed the cost effectiveness of computer assisted surgery versus conventional arthroplasty with respect to implant survival and operation volume in two theoretical Norwegian age cohorts. We obtained mortality and hospital cost data over a 20-year period from Norwegian registers. We presumed that the cost of an intervention would need to be below NOK 500,000 per QALY (Quality Adjusted Life Year) gained, to be considered cost effective. The added cost of computer assisted surgery, provided this has no impact on implant survival, is NOK 1037 and NOK 1414 respectively for 60 and 75-year-olds per quality-adjusted life year at a volume of 25 prostheses per year, and NOK 128 and NOK 175 respectively at a volume of 250 prostheses per year. Sensitivity analyses showed that the 10-year implant survival in cohort 1 needs to rise from 89.8% to 90.6% at 25 prostheses per year, and from 89.8 to 89.9% at 250 prostheses per year for computer assisted surgery to be considered cost effective. In cohort 2, the required improvement is a rise from 95.1% to 95.4% at 25 prostheses per year, and from 95.10% to 95.14% at 250 prostheses per year. The cost of using computer navigation for total knee replacements may be acceptable for 60-year-old as well as 75-year-old patients if the technique increases the implant survival rate just marginally, and the department has a high operation volume. A low volume department might not achieve cost-effectiveness unless computer navigation has a more significant impact on implant survival, thus may defer the investments until such data are available.

  16. Detection of total knee prostheses at airport security checkpoints.

    PubMed

    Naziri, Qais; Johnson, Aaron J; Hooper, Hasan A; Sana, Said H; Mont, Michael A

    2012-06-01

    Airport security screening measures have changed substantially during the past decade, but few reports have examined how this affects patients who have undergone knee arthroplasties. The purpose of this study was to characterize the efficacy of airport metal detection of total knee prostheses, the delays faced, any inconvenience this may have caused, and the role of implant identification cards. Ninety-seven total knee arthroplasty recipients reported passing through an airport metal detector, with 70 triggering the alarm a mean of 3 times (range, 1-36). The presence of a single-knee prosthesis triggered airport security alarms more than 83% of the time and increased patient inconvenience. Patients should be informed about this chance and be prepared to present documentation of their prosthesis. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. A method for performance comparison of polycentric knees and its application to the design of a knee for developing countries.

    PubMed

    Anand, T S; Sujatha, S

    2017-08-01

    Polycentric knees for transfemoral prostheses have a variety of geometries, but a survey of literature shows that there are few ways of comparing their performance. Our objective was to present a method for performance comparison of polycentric knee geometries and design a new geometry. In this work, we define parameters to compare various commercially available prosthetic knees in terms of their stability, toe clearance, maximum flexion, and so on and optimize the parameters to obtain a new knee design. We use the defined parameters and optimization to design a new knee geometry that provides the greater stability and toe clearance necessary to navigate uneven terrain which is typically encountered in developing countries. Several commercial knees were compared based on the defined parameters to determine their suitability for uneven terrain. A new knee was designed based on optimization of these parameters. Preliminary user testing indicates that the new knee is very stable and easy to use. The methodology can be used for better knee selection and design of more customized knee geometries. Clinical relevance The method provides a tool to aid in the selection and design of polycentric knees for transfemoral prostheses.

  18. Femoro-tibial kinematics after TKA in fixed- and mobile-bearing knees in the sagittal plane.

    PubMed

    Daniilidis, Kiriakos; Höll, Steffen; Gosheger, Georg; Dieckmann, Ralf; Martinelli, Nicolo; Ostermeier, Sven; Tibesku, Carsten O

    2013-10-01

    Lack of the anterior cruciate ligament in total knee arthroplasty results in paradoxical movement of the femur as opposed to the tibia under deep flexion. Total knee arthroplasty with mobile-bearing inlays has been developed to provide increased physiological movement of the knee joint and to reduce polyethylene abrasion. The aim of this study was to perform an in vitro analysis of the kinematic movement in the sagittal plane in order to show differences between fixed- and mobile-bearing TKA in comparison with the natural knee joint. Seven knee joints of human cadaver material were used in a laboratory experiment. Fixed- and mobile-bearing inlays were tested in sequences under isokinetic extension in so-called kinemator for knee joints, which can simulate muscular traction power by the use of hydraulic cylinders, which crossover the knee joint. As a target parameter, the a.p. translation of the tibio-femoral relative movement was measured in the sagittal plane under ultrasound (Zebris) control. The results show a reduced tibial a.p. translation in relation to the femur in the bearing group compared to the natural joint. In the Z-axis, between 110° and 50° of flexion, linear movement decreases towards caudal movement under extension. Admittedly, the study did not show differences in the movement pattern between "mobile-bearing" and "fixed-bearing" prostheses. Results of this study cannot prove functional advantages of mobile-bearing prostheses for the knee joint kinematic after TKA. Both types of prostheses show typical kinematics of an anterior instability, hence they were incapable of performing physiological movement.

  19. Minimally invasive knee arthroplasty: An overview

    PubMed Central

    Tria, Alfred J; Scuderi, Giles R

    2015-01-01

    Minimally invasive surgery (MIS) for arthroplasty of the knee began with surgery for unicondylar knee arthroplasty (UKA). Partial knee replacements were designed in the 1970s and were amenable to a more limited exposure. In the 1990s Repicci popularized the MIS for UKA. Surgeons began to apply his concepts to total knee arthroplasty. Four MIS surgical techniques were developed: quadriceps sparing, mini-mid vastus, mini-subvastus, and mini-medial parapatellar. The quadriceps sparing technique is the most limited one and is also the most difficult. However, it is the least invasive and allows rapid recovery. The mini-midvastus is the most common technique because it affords slightly better exposure and can be extended. The mini-subvastus technique entirely avoids incising the quadriceps extensor mechanism but is time consuming and difficult in the obese and in the muscular male patient. The mini-parapatellar technique is most familiar to surgeons and represents a good starting point for surgeons who are learning the techniques. The surgeries are easier with smaller instruments but can be performed with standard ones. The techniques are accurate and do lead to a more rapid recovery, with less pain, less blood loss, and greater motion if they are appropriately performed. PMID:26601062

  20. Sensitivity of biomechanical outcomes to independent variations of hindfoot and forefoot stiffness in foot prostheses.

    PubMed

    Adamczyk, Peter Gabriel; Roland, Michelle; Hahn, Michael E

    2017-08-01

    Many studies have reported the effects of different foot prostheses on gait, but most results cannot be generalized because the prostheses' properties are seldom reported. We varied hindfoot and forefoot stiffness in an experimental foot prosthesis, in increments of 15N/mm, and tested the parametric effects of these variations on treadmill walking in unilateral transtibial amputees, at speeds from 0.7 to 1.5m/s. We computed outcomes such as prosthesis energy return, center of mass (COM) mechanics, ground reaction forces, and joint mechanics, and computed their sensitivity to component stiffness. A stiffer hindfoot led to reduced prosthesis energy return, increased ground reaction force (GRF) loading rate, and greater stance-phase knee flexion and knee extensor moment. A stiffer forefoot resulted in reduced prosthetic-side ankle push-off and COM push-off work, and increased knee extension and knee flexor moment in late stance. The sensitivity parameters obtained from these tests may be useful in clinical prescription and further research into compensatory mechanisms of joint function. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Biomechanical study of the tibia in knee replacement revision.

    PubMed

    Quílez, M P; Pérez, M A; Seral-García, B

    2015-01-01

    The best management of severe bone defects following total knee replacement is still controversial. Metal augments, tantalum cones and porous tibial sleeves could help the surgeon to manage any type of bone loss, providing a stable and durable knee joint reconstruction. Five different types of prostheses have been analysed: one prosthesis with straight stem; two prostheses with offset stem, with and without supplement, and two prostheses with sleeves, with and without stem. The purpose of this study is to report a finite element study of revision knee tibial implants. The main objective was to analyse the tibial bone density changes and Von Misses tension changes following different tibial implant designs. In all cases, the bone density decreases in the proximal epiphysis and medullary channels, with a bone density increase also being predicted in the diaphysis and at the bone around the stems tips. The highest value of Von Misses stress has been obtained for the straight tibial stem, and the lowest for the stemless metaphyseal sleeves prosthesis. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.

  2. Comparative study of design and PCL-substituting systems of total knee prosthesis.

    PubMed

    Adam, R; Orban, C; Orban, H

    2014-01-01

    The aim of this study is to assess postoperative results obtained by different knee implants. The main implant types differences are given by generally implant design and by PCL substituting systems that are used. Between 04.2004 - 02.2012 we have performed 506 total knee arthroplasties (TKA), on a group of 460 patients. Our choice, was for cemented total knee prostheses, using PCL-substituting systems. Regarding general design and PCL-substituting systems of the implant we had divided the main group in three lots. In order to assess post operative result we had used the American Knee Society Score(AKSS). All prostheses types that we had implanted, had registered satisfactory values of AKSS. Our study showed that one group scored higher values of AKSS, compared the other two, but there are not statistical semnificative differences (p=0,09). Celsius.

  3. Mid-term results of lateral unicondylar mobile bearing knee arthroplasty: a multicentre study of 363 cases.

    PubMed

    Walker, T; Zahn, N; Bruckner, T; Streit, M R; Mohr, G; Aldinger, P R; Clarius, M; Gotterbarm, T

    2018-01-01

    The aim of this independent multicentre study was to assess the mid-term results of mobile bearing unicondylar knee arthroplasty (UKA) for isolated lateral osteoarthritis of the knee joint. We retrospectively evaluated 363 consecutive, lateral UKAs (346 patients) performed using the Oxford domed lateral prosthesis undertaken in three high-volume knee arthroplasty centres between 2006 and 2014. Mean age of the patients at surgery was 65 years (36 to 88) with a mean final follow-up of 37 months (12 to 93) RESULTS: A total of 36 (10.5%) patients underwent revision surgery, giving a survival rate of 90.1% at three years (95% confidence intervals (CI) 86.1 to 93.1; number at risk: 155) and 85.0% at five years (95% CI 77.9 to 89.9; number at risk: 43). Dislocation of the mobile bearing occurred in 18 patients (5.6%) at three years (95% CI 1.0 to 16.4; number at risk: 154) and in 20 patients (8.5%) at five years (95% CI 1.0 to 27.0; number at risk: 42). There were no significant differences in the dislocation rate between the participating centres or the surgeons. We were not able to identify an effect of each surgeon's learning curve on the dislocation rate of the mobile bearing. The clinical outcome in patients without revision surgery at final follow-up was good to excellent, with a mean Oxford knee score of 40.3 (95% CI 39.4 to 41.2), a mean Tegner activity score of 3.2 (95% CI 3.1 to 3.3) and a mean University of California, Los Angeles score of 5.7 (95% CI 5.5 to 5.9). Our data, which consists of a high number of patients treated with mobile bearing UKA in the lateral compartment, indicates a high revision rate of 15% at five years with dislocation of the mobile bearing being the main reason for implant failure. Despite the good functional and clinical results and the high patient satisfaction in our study group, we therefore discontinued using mobile-bearing lateral UKA in favour of a fixed-bearing component. Cite this article: Bone Joint J 2018;100-B:42-9. ©2018 The British Editorial Society of Bone & Joint Surgery.

  4. 10-year evaluation of the cementless low-contact- stress rotating-platform total knee arthroplasty.

    PubMed

    Efstathopoulos, Nikolaos; Mavrogenis, Andreas F; Lallos, Stergios; Nikolaou, Vassilios; Papagelopoulos, Panayiotis J; Savvidou, Olga D; Korres, Demetrios S

    2009-01-01

    We present the clinical and radiographic outcomes of the cementless low-contact-stress (LCS) rotating-platform total knee arthroplasty. Overall, 423 prostheses were implanted in 393 consecutive patients (30 patients had bilateral total knee replacement) for primary varus gonarthrosis (381 patients) and rheumatoid arthritis (12 patients). There were 81 men and 312 women with a mean age of 73 years (range, 58-85 years). Patella replacement was not performed in any case. Clinical and radiographic evaluation was performed using the Knee Society Score (KSS) and the Knee Society Assessment Form, respectively. The mean follow-up was 10 years (range, 5-15 years). Three patients were lost to follow-up. Survival of the prostheses was 98% at 10 years; three prostheses required revision for deep infection, bearing dislocation, and periprosthetic fracture. The mean KSS improved significantly, from 42 and 44 points preoperatively to 90 and 79 points, respectively, at the latest evaluation (P < 0.001); results were excellent in 278 cases, good in 106, fair in 27, and poor in nine. Radiolucent lines were observed in 80 cases; revision arthroplasty was not performed in any of these cases. Complications included deep infection in one patient, bearing dislocation in one, skin necrosis in four, and a supracondylar fracture in one. The cementless LCS rotating-platform total knee arthroplasty is associated with excellent mid- and long-term results for patients with osteoarthritis and rheumatoid arthritis of the knee.

  5. Quadriceps muscle injury in trans-femoral amputees.

    PubMed

    Alsindi, Z; Datta, D

    1998-12-01

    Two male trans-femoral amputees using modular trans-femoral prostheses lost control and fell to the ground when their prosthetic knees gave way. The semi-automatic knee lock malfunctioned in the first case while the free knee stabilising mechanics gave way in the second case. This resulted in a high tensile force acting on the contralateral quadriceps muscle causing it to rupture. As there are a significant number of patients with both kinds of prostheses it is important to be aware of this possibility so that necessary actions can be taken to minimise its occurrence. Even with the currently available weight activated stance phase control, the prosthetic knee will give way if the knee is flexed more than 20 degrees on weight bearing. Good power and control of hip extensors on the amputation side is needed to control the prosthetic knee joint, especially in the early stage of the walking cycle, i.e., from heel strike to mid-stance. Quadriceps muscle injury in amputees, as far as the authors are aware, has not been reported previously.

  6. A 3D finite element model to investigate prosthetic interface stresses of different posterior tibial slope.

    PubMed

    Shen, Yi; Li, Xiaomiao; Fu, Xiaodong; Wang, Weili

    2015-11-01

    Posterior tibial slope that is created during proximal tibial resection in total knee arthroplasty has emerged as an important factor in the mechanics of the knee joint and the surgical outcome. But the ideal degree of posterior tibial slope for recovery of the knee joint function and preventions of complications remains controversial and should vary in different racial groups. The objective of this paper is to investigate the effects of posterior tibial slope on contact stresses in the tibial polyethylene component of total knee prostheses. Three-dimensional finite element analysis was used to calculate contact stresses in tibial polyethylene component of total knee prostheses subjected to a compressive load. The 3D finite element model of total knee prosthesis was constructed from the images produced by 3D scanning technology. Stresses in tibial polyethylene component were calculated with four different posterior tibial slopes (0°, 3°, 6° and 9°). The 3D finite element model of total knee prosthesis we presented was well validated. We found that the stress distribution in the polythene as evaluated by the distributions of the von Mises stress, the maximum principle stress, the minimum principle stress and the Cpress were more uniform with 3° and 6° posterior tibial slopes than with 0° and 9° posterior tibial slopes. Moreover, the peaks of the above stresses and trends of changes with increasing degree of knee flexion were more ideal with 3° and 6° posterior slopes. The results suggested that the tibial component inclination might be favourable to 7°-10° so far as the stress distribution is concerned. The range of the tibial component inclination also can decrease the wear of polyethylene. Chinese posterior tibial slope is bigger than in the West, and the current domestic use of prostheses is imported from the West, so their demands to tilt back bone cutting can lead to shorten the service life of prostheses; this experiment result is of important clinical significance, guiding orthopaedic surgeon after the best angle to cut bone.

  7. Morphometric evaluation of the knee in Chinese population reveals sexual dimorphism and age-related differences.

    PubMed

    Li, Ke; Cavaignac, Etienne; Xu, Wei; Cheng, Qiang; Telmon, Nobert; Huang, Wei

    2018-02-20

    Morphologic data of the knee is very important in the design of total knee prostheses. Generally, the designs of the total knee prostheses are based on the knee anatomy of Caucasian population. Moreover, in forensic medicine, a person's age and sex might be estimated by the shape of their knees. The aim of this study is to utilize three-dimensional morphometric analysis of the knee in Chinese population to reveal sexual dimorphism and age-related differences. Sexually dimorphic differences and age-related differences of the distal femur were studied by using geometric morphometric analysis of ten osteometric landmarks on three-dimensional reconstructions of 259 knees in Chinese population. General Procrustes analysis, PCA, and other discriminant analysis such as Mahalanobis and Goodall's F test were conducted for the knee to identify sexually dimorphism and age-related differences of the knee. The shape of distal femur between the male and female is significantly different. A difference between males and females in distal femur shape was identified by PCA; PC1 and PC2 accounted for 61.63% of the variance measured. The correct sex was assigned in 84.9% of cases by CVA, and the cross-validation revealed a 81.1% rate of correct sex estimation. The osteometric analysis also showed significant differences between the three age-related subgroups (< 40, 40-60, > 60 years, p < 0.005). This study showed both sex-related difference and age-related difference in the distal femur in Chinese population by 3D geometric morphometric analysis. Our bone measurements and geometric morphometric analysis suggest that population characteristics should be taken into account and may provide references for design of total knee prostheses in a Chinese population. Moreover, this reliable, accurate method could be used to perform diachronic and interethnic comparisons.

  8. Comparison of patellofemoral outcomes after TKA using two prostheses with different patellofemoral design features.

    PubMed

    Bae, Dae Kyung; Baek, Jong Hun; Yoon, Kyung Tack; Son, Hyuck Sung; Song, Sang Jun

    2017-12-01

    The purpose of the present study was to compare the clinical and radiographic results after TKA using two prostheses with different sagittal patellofemoral design features, including outcomes related to compatibility of the patellofemoral joint. The clinical and radiographic results of 81 patients (100 knees) who underwent TKA using the specific prosthesis (group A) were compared with those in a control group who underwent TKA using the other prosthesis (group B). The presence of anterior knee joint pain, patellar crepitation, and patellar clunk syndrome was also checked. The function score and maximum flexion angle at the last follow-up were slightly better in group A than those in group B (92.0 ± 2.3 vs. 90.6 ± 4.2) (133.6° ± 8.4° vs. 129.6° ± 11.4°). Anterior knee pain was observed in 6 knees and patellar crepitation in four knees in group A. In group B, these symptoms were observed in 22 knees and 18 knees, respectively. There was no patellar clunk syndrome in either group. The alignment was corrected with satisfactory positioning of components. The patellar height remained unchanged after TKA in the two groups. The differences between preoperative and postoperative patellar tilt angle and patellar translation were small. When comparing the clinical and radiographic results after TKA using two prostheses with different sagittal patellofemoral design features, TKA using the specific prosthesis provided satisfactory results with less clinical symptoms related to the patellofemoral kinematics with TKA using the other prosthesis. III.

  9. Clinical Outcomes in Men and Women following Total Knee Arthroplasty with a High-Flex Knee: No Clinical Effect of Gender.

    PubMed

    Nassif, Jeffrey M; Pietrzak, William S

    2015-01-01

    While it is generally recognized that anatomical differences exist between the male and female knee, the literature generally refutes the clinical need for gender-specific total knee prostheses. It has been found that standard, unisex knees perform as well, or better, in women than men. Recently, high-flex knees have become available that mechanically accommodate increased flexion yet no studies have directly compared the outcomes of these devices in men and women to see if gender-based differences exist. We retrospectively compared the performance of the high-flex Vanguard knee (Biomet, Warsaw, IN) in 716 male and 1,069 female knees. Kaplan-Meier survivorship was 98.5% at 5.6-5.7 years for both genders. After 2 years, mean improvements in Knee Society Knee and Function scores for men and women (50.9 versus 46.3; 26.5 versus 23.1) and corresponding SF-12 Mental and Physical scores (0.2 versus 2.2; 13.7 versus 12.2) were similar with differences not clinically relevant. Postoperative motion gains as a function of preoperative motion level were virtually identical in men and women. This further confirms the suitability of unisex total knee prostheses for both men and women.

  10. Design and Control of a New Biomimetic Transfemoral Knee Prosthesis Using an Echo-Control Scheme

    PubMed Central

    2018-01-01

    Passive knee prostheses require a significant amount of additional metabolic energy to carry out a gait cycle, therefore affecting the natural human walk performance. Current active knee prostheses are still limited because they do not reply with accuracy of the natural human knee movement, and the time response is relatively large. This paper presents the design and control of a new biomimetic-controlled transfemoral knee prosthesis based on a polycentric-type mechanism. The aim was to develop a knee prosthesis able to provide additional power and to mimic with accuracy of the natural human knee movement using a stable control strategy. The design of the knee mechanism was obtained from the body-guidance kinematics synthesis based on real human walking patterns obtained from computer vision and 3D reconstruction. A biomechanical evaluation of the synthesized prosthesis was then carried out. For the activation and control of the prosthesis, an echo-control strategy was proposed and developed. In this echo-control strategy, the sound side leg is sensed and synchronized with the activation of the knee prosthesis. An experimental prototype was built and evaluated in a test rig. The results revealed that the prosthetic knee is able to mimic the biomechanics of the human knee. PMID:29854368

  11. Wear simulation of total knee prostheses using load and kinematics waveforms from stair climbing.

    PubMed

    Abdel-Jaber, Sami; Belvedere, Claudio; Leardini, Alberto; Affatato, Saverio

    2015-11-05

    Knee wear simulators are meant to perform load cycles on knee implants under physiological conditions, matching exactly, if possible, those experienced at the replaced joint during daily living activities. Unfortunately, only conditions of low demanding level walking, specified in ISO-14243, are used conventionally during such tests. A recent study has provided a consistent knee kinematic and load data-set measured during stair climbing in patients implanted with a specific modern total knee prosthesis design. In the present study, wear simulation tests were performed for the first time using this data-set on the same prosthesis design. It was hypothesised that more demanding tasks would result in wear rates that differ from those observed in retrievals. Four prostheses for total knee arthroplasty were tested using a displacement-controlled knee wear simulator for two million cycles at 1.1 Hz, under kinematics and load conditions typical of stair climbing. After simulation, the corresponding damage scars on the bearings were qualified and compared with equivalent explanted prostheses. An average mass loss of 20.2±1.5 mg was found. Scanning digital microscopy revealed similar features, though the explant had a greater variety of damage modes, including a high prevalence of adhesive wear damage and burnishing in the overall articulating surface. This study confirmed that the results from wear simulation machines are strongly affected by kinematics and loads applied during simulations. Based on the present results for the full understanding of the current clinical failure of knee implants, a more comprehensive series of conditions are necessary for equivalent simulations in vitro. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. RSA and registries: the quest for phased introduction of new implants.

    PubMed

    Nelissen, Rob G H H; Pijls, Bart G; Kärrholm, Johan; Malchau, Henrik; Nieuwenhuijse, Marc J; Valstar, Edward R

    2011-12-21

    Although the overall survival of knee and hip prostheses at ten years averages 90%, recent problems with several hip and knee prostheses have illustrated that the orthopaedic community, industry, and regulators can still further improve patient safety. Given the early predictive properties of roentgen stereophotogrammetric analysis (RSA) and the meticulous follow-up of national joint registries, these two methods are ideal tools for such a phased clinical introduction. In this paper, we elaborate on the predictive power of RSA within a two-year follow-up after arthroplasty and its relationship to national joint registries. The association between RSA prosthesis-migration data and registry data is evaluated. The five-year rate of revision of RSA-tested total knee replacements was compared with that of non-RSA-tested total knee replacements. Data were extracted from the published results of the national joint registries of Sweden, Australia, and New Zealand. There was a 22% to 35% reduction in the number of revisions of RSA-tested total knee replacements as compared with non-RSA-tested total knee replacements in the national joint registries. Assuming that the total cost of total knee arthroplasty is $37,000 in the United States, a 22% to 35% reduction in the number of revisions (currently close to 55,000 annually) could lead to an estimated annual savings of over $400 million to the health-care system. The phased clinical introduction of new prostheses with two-year RSA results as a qualitative tool could lead to better patient care and could reduce the costs associated with revision total knee arthroplasty. Follow-up in registries is necessary to substantiate these results and to improve post-market surveillance.

  13. Mobile vs. fixed bearing unicondylar knee arthroplasty: A randomized study on short term clinical outcomes and knee kinematics.

    PubMed

    Li, Ming G; Yao, Felix; Joss, Brendan; Ioppolo, James; Nivbrant, Bo; Wood, David

    2006-10-01

    The literature contains limited yet controversial information regarding whether a fixed or a mobile bearing implant should be used in unicompartmental knee arthroplasty (UKA). This randomized study was to further document the performance and comparison of the two designs. Fifty-six knees in 48 patients (mean age of 72 years) undergoing medial UKA were randomized into a fixed bearing (Miller/Galante) or a mobile bearing (Oxford) UKA. The 2 year clinical outcomes (clinical scores), radiographic findings, and weight bearing knee kinematics (assessed using RSA) were compared between the two groups. The mobile bearing knees displayed a larger and an incrementally increased tibial internal rotation (4.3 degrees, 7.6 degrees, 9.5 degrees vs. 3.0 degrees, 3.0 degrees, 4.2 degrees respectively at 30 degrees, 60 degrees, 90 degrees of knee flexion) compared to the fixed ones. The medial femoral condyle in the mobile bearing knees remained 2 mm from the initial position vs. a 4.2 mm anterior translation in the fixed bearing knees during knee flexion. The contact point in the mobile bearing implant moved 2 mm posteriorly vs. a 6 mm anterior movement in the other group. The mobile bearing knees had a lower incidence of radiolucency at the bone implant interface (8% vs. 37%, p < 0.05). The incidence of lateral compartment OA and progression of OA at patello-femoral joint were equal. No differences were found regarding Knee Society Scores, WOMAC, and SF-36 scores (p > 0.05). This study indicates that mobile bearing knees had a better kinematics, a lower incidence of radiolucency but not yet a better knee function at 2 years.

  14. Energy expenditure of wheeling and walking during prosthetic rehabilitation in a woman with bilateral transfemoral amputations.

    PubMed

    Wu, Y J; Chen, S Y; Lin, M C; Lan, C; Lai, J S; Lien, I N

    2001-02-01

    To compare the energy expenditure of locomotion by wheelchair with that required for prosthetic ambulation in a person with bilateral transfemoral (TF) amputations. Observational, single patient, descriptive. An 80-meter long rectangular hallway in a rehabilitation unit. A 41-year-old woman with bilateral TF amputations that were performed 79 days before her admission to the rehabilitation unit. The oxygen uptake, oxygen cost, heart rate, speed, cadence, and stride length of walking measured during a 4-month course of prosthetic rehabilitation. Five locomotion conditions were evaluated: (1) wheelchair propulsion, (2) walking with short-leg prostheses (stubbies) and a walker, (3) long-leg prostheses and a walker, (4) long-leg prostheses without knee mechanism and axillary crutches, and (5) long-leg prostheses with right polycentric knee and left locked knee and axillary crutches. A portable and telemetric system was used to measure the metabolic parameters. An arm ergometry graded exercise test was performed at the end of rehabilitation. Oxygen cost (range, 466%--707% of that of wheeling) and heart rate (range, 106%--116% of that of wheeling) were higher during walking with various combinations of prostheses and walking aids. The speed of prosthetic walking was only 24% to 33% of that of wheeling. Our patient preferred using a wheelchair to prosthetic walking after discharge. People with bilateral TF amputations require very high cardiorespiratory endurance to fulfill the energy demand during prosthetic rehabilitation. The high energy cost of prosthetic walking will limit its application in daily activities.

  15. Quadriceps force during knee extension in different replacement scenarios with a modular partial prosthesis.

    PubMed

    Calliess, Tilman; Schado, Ssuheib; Richter, Berna I; Becher, Christoph; Ezechieli, Marco; Ostermeier, Sven

    2014-02-01

    Previous biomechanical studies have shown that bi-cruciate retaining knee replacement does not significantly alter normal knee kinematics, however, there are no data on the influence of a combined medial and patellofemoral bi-compartimental arthroplasty. The purpose of this in vitro study was to evaluate the effect of different replacement scenarios with a modular partial knee replacement system on the amount of quadriceps force required to extend the knee during an isokinetic extension cycle. Ten human knee specimens were tested in a kinematic knee simulator under (1) physiologic condition and after subsequent implantation of (2) a medial unicondylar and (3) a trochlear replacement. An isokinetic extension cycle of the knee with a constant extension moment of 31 Nm was simulated. The resulting quadriceps extension force was measured from 120° to full knee extension. The quadriceps force curve described a typically sinusoidal characteristic before and after each replacement scenario. The isolated medial replacement resulted in a slightly, but significantly higher maximum quadriceps force (1510 N vs. 1585 N, P = 0.006) as well as the subsequent trochlear replacement showed an additional increase (1801 N, P = 0.008). However, for both replacements no significant difference to the untreated condition could be detected in mid-flexion (10-50°). When considering a bi-compartimental replacement an increase of required maximum quadriceps force needed to extend the knee has to keep in mind. However, the close to physiological movement in mid-flexion suggests that patients with a bi-crutiate retaining arthroplasty might have an advantage in knee stability compared to total knee arthroplasty. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. A novel standardized algorithm using SPECT/CT evaluating unhappy patients after unicondylar knee arthroplasty--a combined analysis of tracer uptake distribution and component position.

    PubMed

    Suter, Basil; Testa, Enrique; Stämpfli, Patrick; Konala, Praveen; Rasch, Helmut; Friederich, Niklaus F; Hirschmann, Michael T

    2015-03-20

    The introduction of a standardized SPECT/CT algorithm including a localization scheme, which allows accurate identification of specific patterns and thresholds of SPECT/CT tracer uptake, could lead to a better understanding of the bone remodeling and specific failure modes of unicondylar knee arthroplasty (UKA). The purpose of the present study was to introduce a novel standardized SPECT/CT algorithm for patients after UKA and evaluate its clinical applicability, usefulness and inter- and intra-observer reliability. Tc-HDP-SPECT/CT images of consecutive patients (median age 65, range 48-84 years) with 21 knees after UKA were prospectively evaluated. The tracer activity on SPECT/CT was localized using a specific standardized UKA localization scheme. For tracer uptake analysis (intensity and anatomical distribution pattern) a 3D volumetric quantification method was used. The maximum intensity values were recorded for each anatomical area. In addition, ratios between the respective value in the measured area and the background tracer activity were calculated. The femoral and tibial component position (varus-valgus, flexion-extension, internal and external rotation) was determined in 3D-CT. The inter- and intraobserver reliability of the localization scheme, grading of the tracer activity and component measurements were determined by calculating the intraclass correlation coefficients (ICC). The localization scheme, grading of the tracer activity and component measurements showed high inter- and intra-observer reliabilities for all regions (tibia, femur and patella). For measurement of component position there was strong agreement between the readings of the two observers; the ICC for the orientation of the femoral component was 0.73-1.00 (intra-observer reliability) and 0.91-1.00 (inter-observer reliability). The ICC for the orientation of the tibial component was 0.75-1.00 (intra-observer reliability) and 0.77-1.00 (inter-observer reliability). The SPECT/CT algorithm presented combining the mechanical information on UKA component position, alignment and metabolic data is highly reliable and proved to be a valuable, consistent and useful tool for analysing postoperative knees after UKA. Using this standardized approach in clinical studies might be helpful in establishing the diagnosis in patients with pain after UKA.

  17. Is the posterior cruciate ligament necessary for medial pivot knee prostheses with regard to postoperative kinematics?

    PubMed

    Fang, Chao-Hua; Chang, Chia-Ming; Lai, Yu-Shu; Chen, Wen-Chuan; Song, Da-Yong; McClean, Colin J; Kao, Hao-Yuan; Qu, Tie-Bing; Cheng, Cheng-Kung

    2015-11-01

    Excellent clinical and kinematical performance is commonly reported after medial pivot knee arthroplasty. However, there is conflicting evidence as to whether the posterior cruciate ligament should be retained. This study simulated how the posterior cruciate ligament, post-cam mechanism and medial tibial insert morphology may affect postoperative kinematics. After the computational intact knee model was validated according to the motion of a normal knee, four TKA models were built based on a medial pivot prosthesis; PS type, modified PS type, CR type with PCL retained and CR type with PCL sacrificed. Anteroposterior translation and axial rotation of femoral condyles on the tibia during 0°-135° knee flexion were analyzed. There was no significant difference in kinematics between the intact knee model and reported data for a normal knee. In all TKA models, normal motion was almost fully restored, except for the CR type with PCL sacrificed. Sacrificing the PCL produced paradoxical anterior femoral translation and tibial external rotation during full flexion. Either the posterior cruciate ligament or post-cam mechanism is necessary for medial pivot prostheses to regain normal kinematics after total knee arthroplasty. The morphology of medial tibial insert was also shown to produce a small but noticeable effect on knee kinematics. V.

  18. In vivo kinematics of a robot-assisted uni- and multi-compartmental knee arthroplasty.

    PubMed

    Watanabe, Toshifumi; Abbasi, Ali Z; Conditt, Michael A; Christopher, Jennifer; Kreuzer, Stefan; Otto, Jason K; Banks, Scott A

    2014-07-01

    There is great interest in providing reliable and durable treatments for one- and two-compartment arthritic degeneration of the cruciate-ligament intact knee. One approach is to resurface only the diseased compartments with discrete unicompartmental components, retaining the undamaged compartment(s). However, placing multiple small implants into the knee presents a greater surgical challenge than total knee arthroplasty, so it is not certain that the natural knee mechanics can be maintained or restored. The goal of this study was to determine whether near-normal knee kinematics can be obtained with a robot-assisted multi-compartmental knee arthroplasty. Thirteen patients with 15 multi-compartmental knee arthroplasties using haptic robotic-assisted bone preparation were involved in this study. Nine subjects received a medial unicompartmental knee arthroplasty (UKA), three subjects received a medial UKA and patellofemoral (PF) arthroplasty, and three subjects received medial and lateral bi-unicondylar arthroplasty. Knee motions were recorded using video-fluoroscopy an average of 13 months (6-29 months) after surgery during stair and kneeling activities. The three-dimensional position and orientation of the implant components were determined using model-image registration techniques. Knee kinematics during maximum flexion kneeling showed femoral external rotation and posterior lateral condylar translation. All knees showed femoral external rotation and posterior condylar translation with flexion during the step activity. Knees with medial UKA and PF arthroplasty showed the most femoral external rotation and posterior translation, and knees with bicondylar UKA showed the least. Knees with accurately placed uni- or bi-compartmental arthroplasty exhibited stable knee kinematics consistent with intact and functioning cruciate ligaments. The patterns of tibiofemoral motion were more similar to natural knees than commonly has been observed in knees with total knee arthroplasty. Larger series are required to confirm these as general observations, but the present results demonstrate the potential to restore or maintain closer-to-normal knee kinematics by retaining intact structures and compartments.

  19. Frontal plane stability following UKA in a biomechanical study.

    PubMed

    Heyse, Thomas J; Tucker, Scott M; Rajak, Yogesh; Kia, Mohammad; Lipman, Joseph D; Imhauser, Carl W; Westrich, Geoffrey H

    2015-06-01

    Function and kinematics following unicondylar knee arthroplasty (UKA) have been reported to be close to the native knee. Gait, stair climbing and activities of daily living expose the knee joint to a combination of varus and valgus moments. Replacement of the medial compartment via UKA is likely to change the physiologic knee stability and its ability to respond to varus and valgus moments. It was hypothesized that UKA implantation would stiffen the knee and decrease range of motion in the frontal plane. Six fresh frozen cadaver knees were prepared and mounted in a six-degrees-of-freedom robot. An axial load of 200 N was applied with the knee in 15°, 45° and 90° of flexion. Varus and valgus moments were added, respectively, before and after implantation of medial UKA. Tests were than redone with a thicker polyethylene inlay to simulate overstuffing of the medial compartment. Range of motion in the frontal plane and the tibial response to moments were recorded via the industrial robot. The range of motion in the frontal plane was decreased with both, balanced and overstuffed UKA and shifted towards valgus. When exposed to valgus moments, knees following UKA were stiffer in comparison with the native knee. The effect was even more pronounced with medial overstuffing. In UKA, the compressive anatomy is replaced by much stiffer components. This lack of medial compression and relative overstuffing leads to a tighter medial collateral ligament. This drives the trend towards a stiffer joint as documented by a decrease in frontal plane range of motion. Overstuffing should strictly be avoided when performing UKA.

  20. 21 CFR 888.3535 - Knee joint femorotibial (uni-compartmental) metal/polymer porous-coated uncemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... across-the-joint. This generic type of device is designed to achieve biological fixation to bone without the use of bone cement. This identification includes fixed-bearing knee prostheses where the ultra...

  1. 21 CFR 888.3535 - Knee joint femorotibial (uni-compartmental) metal/polymer porous-coated uncemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... across-the-joint. This generic type of device is designed to achieve biological fixation to bone without the use of bone cement. This identification includes fixed-bearing knee prostheses where the ultra...

  2. 21 CFR 888.3535 - Knee joint femorotibial (uni-compartmental) metal/polymer porous-coated uncemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... across-the-joint. This generic type of device is designed to achieve biological fixation to bone without the use of bone cement. This identification includes fixed-bearing knee prostheses where the ultra...

  3. 21 CFR 888.3535 - Knee joint femorotibial (uni-compartmental) metal/polymer porous-coated uncemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... across-the-joint. This generic type of device is designed to achieve biological fixation to bone without the use of bone cement. This identification includes fixed-bearing knee prostheses where the ultra...

  4. 21 CFR 888.3535 - Knee joint femorotibial (uni-compartmental) metal/polymer porous-coated uncemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... across-the-joint. This generic type of device is designed to achieve biological fixation to bone without the use of bone cement. This identification includes fixed-bearing knee prostheses where the ultra...

  5. Rapid Prototyping for In Vitro Knee Rig Investigations of Prosthetized Knee Biomechanics: Comparison with Cobalt-Chromium Alloy Implant Material

    PubMed Central

    Schröder, Christian; Steinbrück, Arnd; Müller, Tatjana; Woiczinski, Matthias; Chevalier, Yan; Müller, Peter E.; Jansson, Volkmar

    2015-01-01

    Retropatellar complications after total knee arthroplasty (TKA) such as anterior knee pain and subluxations might be related to altered patellofemoral biomechanics, in particular to trochlear design and femorotibial joint positioning. A method was developed to test femorotibial and patellofemoral joint modifications separately with 3D-rapid prototyped components for in vitro tests, but material differences may further influence results. This pilot study aims at validating the use of prostheses made of photopolymerized rapid prototype material (RPM) by measuring the sliding friction with a ring-on-disc setup as well as knee kinematics and retropatellar pressure on a knee rig. Cobalt-chromium alloy (standard prosthesis material, SPM) prostheses served as validation standard. Friction coefficients between these materials and polytetrafluoroethylene (PTFE) were additionally tested as this latter material is commonly used to protect pressure sensors in experiments. No statistical differences were found between friction coefficients of both materials to PTFE. UHMWPE shows higher friction coefficient at low axial loads for RPM, a difference that disappears at higher load. No measurable statistical differences were found in knee kinematics and retropatellar pressure distribution. This suggests that using polymer prototypes may be a valid alternative to original components for in vitro TKA studies and future investigations on knee biomechanics. PMID:25879019

  6. Control and Evaluation of a Powered Transfemoral Prosthesis for Stair Ascent.

    PubMed

    Ledoux, Elissa D; Goldfarb, Michael

    2017-07-01

    This paper assesses the metabolic effort exerted by three transfemoral amputees, when using a powered knee and ankle prosthesis for stair ascent, relative to ascending stairs with passive knee and ankle prostheses. The paper describes a controller that provides step-over stair ascent behavior reflective of healthy stair ascent biomechanics, and describes its implementation in a powered prosthesis prototype. Stair ascent experiments were performed with three unilateral transfemoral amputee subjects, comparing the oxygen consumption required to ascend stairs using the powered prosthesis (with a step-over gait), relative to using their daily-use energetically passive prostheses (with a step-to gait). Results indicate on average a 24% reduction in oxygen consumption and a 30% reduction in stair ascent timewhen using the powered prosthesis, relative to when using the passive prostheses. All subjects expressed a strong preference for ascending stairs using the powered prosthesis.

  7. Crossover study of amputee stair ascent and descent biomechanics using Genium and C-Leg prostheses with comparison to non-amputee control.

    PubMed

    Lura, Derek J; Wernke, Matthew W; Carey, Stephanie L; Kahle, Jason T; Miro, Rebecca M; Highsmith, M Jason

    2017-10-01

    This study was a randomized crossover of stair ambulation of Transfemoral Amputees (TFAs) using the Genium and C-Leg prosthetic knees. TFAs typically have difficulty ascending and descending stairs, limiting community mobility. The objective of this study was to determine the relative efficacy of the Genium and C-Leg prostheses for stair ascent and descent, and their absolute efficacy relative to non-amputees. Twenty TFAs, and five non-amputees participated in the study. TFAs were randomized to begin the study with the Genium or C-Leg prosthesis. Informed consent was obtained from all participants prior to data collection and the study was listed on clinicaltrials.gov (#NCT01473662). After fitting, accommodation, and training, participants were asked to demonstrate their preferred gait pattern for stair ascent and descent and a step-over-step pattern if able. TFAs then switched prosthetic legs and repeated fitting, accommodation, training, and testing. An eight camera Vicon optical motion analysis system, and two AMTI force plates were used to track and analyze the participants' gait patterns, knee flexion angles, knee moment normalized by body weight, and swing time. For stair descent, no significant differences were found between prostheses. For stair ascent, Genium use resulted in: increased ability to use a step-over-step gait pattern (p=0.03), increased prosthetic side peak knee flexion (p<0.01), and increased swing duration (p<0.01). Changes in contralateral side outcomes and in knee moment were not significant. Overall the Genium knee decreased deficiency in gait patterns for stair ascent relative to the C-Leg, by enabling gait patterns that more closely resembled non-amputees. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Results with nine years mean follow up on one hundred and three KAPS® uni knee arthroplasties: eighty six medial and seventeen lateral.

    PubMed

    Saragaglia, Dominique; Bevand, Adrien; Refaie, Ramsay; Rubens-Duval, Brice; Pailhé, Régis

    2018-05-01

    The purpose of this study was to present the results of the KAPS® uni knee arthroplasty system, both mobile and fixed bearing with reference to function, alignment and complications in 103 implants with a mean follow-up of nine years. This was a retrospective study of 103 unicompartimental knee arthroplasties in 89 patients operated on between March 2005 and March 2010. The population was composed of 50 males and 39 females, with a mean age of 70.5 ± 7.5 years (41 - 90). Eighty-seven patients had a genu varum deformity (84.5%), one of whom had an osteoid osteoma of the lateral tibial plateau and 16 patients had a genu valgum (15.5%). Eighty-six medial prostheses were implanted (82 mobile bearings and 4 fixed bearings) and 17 lateral prostheses (all fixed bearings) including the osteoid osteoma. At a mean follow-up of 107.5 months (73-138), 72 knees (58 patients) were reviewed (70%). The mean IKS score was of 173 ± 31 points (58 - 200). The mean Oxford knee score was 21 ± 8 points (12 - 50). The cumulated survival rate at a follow up of 132 months was 98.2%. The KAPS® unicompartmental knee arthroplasty gives efficacious and safe outcomes in the majority of cases at a mean follow-up of nine years. The availability of both fixed and mobile bearings with the same instrumentation, allowing to choose the right implant intra-operatively, is a great advantage in order to avoid the occurrence of some complications, specific to mobile bearing prostheses (dislocation and over-correction).

  9. Arthroplasty knee registry of Catalonia: What scientific evidence supports the implantation of our prosthesis?

    PubMed

    Samaniego Alonso, R; Gaviria Parada, E; Pons Cabrafiga, M; Espallargues Carreras, M; Martinez Cruz, O

    2018-02-28

    In our environment, it is increasingly necessary to perform an activity based on scientific evidence and the field of prosthetic surgery should be governed by the same principles. The national arthroplasty registries allow us to obtain a large amount of data in order to evaluate this technique. The aim of our study is to analyse the scientific evidence that supports the primary total knee arthroplasties implanted in Catalonian public hospitals, based on the Arthoplasty Registry of Catalonia (RACat) MATERIAL AND METHODS: A review of the literature was carried out on knee prostheses (cruciate retaining, posterior stabilized, constricted and rotational) recorded in RACat between the period 2005-2013 in the following databases: Orthopedic Data Evaluation Panel, PubMed, TripDatabase and Google Scholar. The prostheses implanted in fewer than 10 units (1,358 prostheses corresponding to 62 models) were excluded. 41,947 prostheses (96.86%) were analysed out of 43,305 implanted, corresponding to 74 different models. In 13 models (n = 4,715) (11.24%) no clinical evidence to support their use was found. In the remaining 36 models (n = 13,609) (32.45%), level iv studies were the most predominant evidence. There was a significant number of implanted prostheses (11.24%) for which no clinical evidence was found. The number of models should be noted, 36 out of 110, with fewer than 10 units implanted. The use of arthroplasty registries has proved an extremely useful tool that allows us to analyse and draw conclusions in order to improve the efficiency of this surgical technique. Copyright © 2018 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  10. Late dislocation of rotating platform in New Jersey Low-Contact Stress knee prosthesis.

    PubMed

    Huang, Chun-Hsiung; Ma, Hon-Ming; Liau, Jiann-Jong; Ho, Fang-Yuan; Cheng, Cheng-Kung

    2002-12-01

    Five patients with late rotational dislocation of the rotating platform bearing in the New Jersey Low-Contact Stress total knee arthroplasty are reported. The prostheses had functioned well for 8 to 12 years before failure. Preoperative radiographs showed asymmetric femorotibial joint spaces. Entrapment of the dislocated bearing in three patients and spontaneous reduction of the dislocated bearing in another two patients were seen at revision. Femorotibial ligamentous instability was found after reduction. The retrieved polyethylene bearings showed advanced wear and cold flow deformities and the thickness was reduced. The revision arthroplasty was accomplished by replacement with a thicker bearing element. Progressive femorotibial ligament laxity and reduction of the thickness of polyethylene with wearing break down the originally well-balanced soft tissue tension of the knee. The rotational degree of the rotating platform bearing is unrestricted, which may result in late dislocation. Polyethylene wear is unavoidable in knee prostheses using metal contact with polyethylene even with a mobile-bearing design. Efforts to reduce polyethylene wear are mandatory.

  11. The Effects of the Inertial Properties of Above-Knee Prostheses on Optimal Stiffness, Damping, and Engagement Parameters of Passive Prosthetic Knees.

    PubMed

    Narang, Yashraj S; Murthy Arelekatti, V N; Winter, Amos G

    2016-12-01

    Our research aims to design low-cost, high-performance, passive prosthetic knees for developing countries. In this study, we determine optimal stiffness, damping, and engagement parameters for a low-cost, passive prosthetic knee that consists of simple mechanical elements and may enable users to walk with the normative kinematics of able-bodied humans. Knee joint power was analyzed to divide gait into energy-based phases and select mechanical components for each phase. The behavior of each component was described with a polynomial function, and the coefficients and polynomial order of each function were optimized to reproduce the knee moments required for normative kinematics of able-bodied humans. Sensitivity of coefficients to prosthesis mass was also investigated. The knee moments required for prosthesis users to walk with able-bodied normative kinematics were accurately reproduced with a mechanical system consisting of a linear spring, two constant-friction dampers, and three clutches (R2=0.90 for a typical prosthetic leg). Alterations in upper leg, lower leg, and foot mass had a large influence on optimal coefficients, changing damping coefficients by up to 180%. Critical results are reported through parametric illustrations that can be used by designers of prostheses to select optimal components for a prosthetic knee based on the inertial properties of the amputee and his or her prosthetic leg.

  12. Development of friction and wear full-scale testing for TKR prostheses with reliable low cost apparatus

    NASA Astrophysics Data System (ADS)

    Suwandi, Agri; Soemardi, Tresna P.; Kiswanto, Gandjar; Kusumaningsih, Widjajalaksmi; I. Gusti Agung I. G., W.

    2018-02-01

    Prostheses products must undergo simulation and physical testing, before clinical testing. Finite element method is a preliminary simulation for in vivo test. The method visualizes the magnitude of the compressive force and the critical location of the Total Knee Replacement (TKR) prostheses design. In vitro testing is classified as physical testing for prostheses product. The test is conducted to evaluate the potential failure of the product and the characteristics of the prostheses TKR material. Friction and wear testing are part of the in vivo test. Motion of knee joints, which results in the phenomena of extension and deflection in the femoral and tibia insert, is represented by friction and wear testing. Friction and wear tests aim to obtain an approximate lifetime in normal and extreme load patterns as characterized by the shape of the friction surface area. The lifetime estimation requires friction and wear full-scale testing equipments for TKR prostheses products. These are necessary in obtaining initial data on potential product failures and characterizing of the material based on the ASTM F2724-08 standards. Based on the testing result and statistical analysis data, the average wear rate value per year is 2.19 × 10-3 mg/MC, with a 10 % safety limit of volume and 14,400 cycles times, for 15 hours moving nonstop then the prediction of wear life of the component tibia insert is ± 10 years.

  13. Above-knee prosthesis design based on fatigue life using finite element method and design of experiment.

    PubMed

    Phanphet, Suwattanarwong; Dechjarern, Surangsee; Jomjanyong, Sermkiat

    2017-05-01

    The main objective of this work is to improve the standard of the existing design of knee prosthesis developed by Thailand's Prostheses Foundation of Her Royal Highness The Princess Mother. The experimental structural tests, based on the ISO 10328, of the existing design showed that a few components failed due to fatigue under normal cyclic loading below the required number of cycles. The finite element (FE) simulations of structural tests on the knee prosthesis were carried out. Fatigue life predictions of knee component materials were modeled based on the Morrow's approach. The fatigue life prediction based on the FE model result was validated with the corresponding structural test and the results agreed well. The new designs of the failed components were studied using the design of experimental approach and finite element analysis of the ISO 10328 structural test of knee prostheses under two separated loading cases. Under ultimate loading, knee prosthesis peak von Mises stress must be less than the yield strength of knee component's material and the total knee deflection must be lower than 2.5mm. The fatigue life prediction of all knee components must be higher than 3,000,000 cycles under normal cyclic loading. The design parameters are the thickness of joint bars, the diameter of lower connector and the thickness of absorber-stopper. The optimized knee prosthesis design meeting all the requirements was recommended. Experimental ISO 10328 structural test of the fabricated knee prosthesis based on the optimized design confirmed the finite element prediction. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  14. The Effect of Adductor-Canal-Blockade on Outcome after Medial Unicondylar Knee Arthroplasty: A Preliminary Study.

    PubMed

    Brown, Matthew L; Seyler, Thorsten M; Allen, John; Plate, Johannes F; Henshaw, Daryl S; Lang, Jason E

    2015-03-01

    Unicondylar knee arthroplasty (UKA) offers decreased morbidity, faster recovery, better functional outcomes, and equivalent survivorship compared to TKA for certain patients. To fully capture these benefits, regional anesthesia techniques must facilitate rather than compromise patients ability for early postoperative mobilization and safe discharge following UKA. The purpose of this study was to determine whether the predominantly sensory adductor canal blockade (ACB) shortens hospital stay after medial UKA (mUKA). Secondary endpoints were narcotic consumption, steps walked during PT sessions, and total PT sessions required prior to discharge. Twelve patients scheduled for elective mUKA received spinal anesthesia and single-shot ACB. ACB patients were matched by age, gender, body mass index (BMI), and Charlson Comorbidity Index in a 1:2 ratio to 24 lumbar plexus block (LPB) patients. Time to hospital discharge, number of physical therapy (PT) sessions required for safe discharge, and steps taken during PT sessions were retrospectively abstracted from each patient's medical record. Patients who received ACB had a significantly shorter hospital stay (27.8 ± 3.9 hours) compared with patients who received LPB (39.7 ±18.5 hours, p = 0.025). Patients treated with ACB required significantly fewer PT sessions (1.3 ± 0.6 sessions) compared to patients who received LPB (2.4 ± 1.5 sessions, p = 0.007). Patients treated with ACB walked significantly more steps during their first PT session (225.0 ± 156.6 steps) compared with patients treated with LPB (107.4 ± 170.0, p = 0.045). There was a trend towards decreased narcotic requirements in the ACB group. Data from our study suggests that ACB may permit earlier hospital discharge and better participation in PT without compromising the quality of perioperative analgesia. Thus, ACB may represent a promising option for patients undergoing mUKA in terms of improved clinical outcomes, decreased postoperative morbidity, and cost-effectiveness.

  15. Return to Sports and Physical Activity After Total and Unicondylar Knee Arthroplasty: A Systematic Review and Meta-Analysis.

    PubMed

    Witjes, Suzanne; Gouttebarge, Vincent; Kuijer, P Paul F M; van Geenen, Rutger C I; Poolman, Rudolf W; Kerkhoffs, Gino M M J

    2016-02-01

    People today are living longer and want to remain active. While obesity is becoming an epidemic, the number of patients suffering from osteoarthritis (OA) is expected to grow exponentially in the coming decades. Patients with OA of the knee are progressively being restricted in their activities. Since a knee arthroplasty (KA) is a well accepted, cost-effective intervention to relieve pain, restore function and improve health-related quality of life, indications are expanding to younger and more active patients. However, evidence concerning return to sports (RTS) and physical activity (PA) after KA is sparse. Our aim was to systematically summarise the available literature concerning the extent to which patients can RTS and be physically active after total (TKA) and unicondylar knee arthroplasty (UKA), as well as the time it takes. PRISMA guidelines were followed and our study protocol was published online at PROSPERO under registration number CRD42014009370. Based on the keywords (and synonyms of) 'arthroplasty', 'sports' and 'recovery of function', the databases MEDLINE, Embase and SPORTDiscus up to January 5, 2015 were searched. Articles concerning TKA or UKA patients who recovered their sporting capacity, or intended to, were included and were rated by outcomes of our interest. Methodological quality was assessed using Quality in Prognosis Studies (QUIPS) and data extraction was performed using a standardised extraction form, both conducted by two independent investigators. Out of 1115 hits, 18 original studies were included. According to QUIPS, three studies had a low risk of bias. Overall RTS varied from 36 to 89% after TKA and from 75 to >100% after UKA. The meta-analysis revealed that participation in sports seems more likely after UKA than after TKA, with mean numbers of sports per patient postoperatively of 1.1-4.6 after UKA and 0.2-1.0 after TKA. PA level was higher after UKA than after TKA, but a trend towards lower-impact sports was shown after both TKA and UKA. Mean time to RTS after TKA and UKA was 13 and 12 weeks, respectively, concerning low-impact types of sports in more than 90 % of cases. Low- and higher-impact sports after both TKA and UKA are possible, but it is clear that more patients RTS (including higher-impact types of sports) after UKA than after TKA. However, the overall quality of included studies was limited, mainly because confounding factors were inadequately taken into account in most studies.

  16. Mobile-bearing knees reduce rotational asymmetric wear.

    PubMed

    Ho, Fang-Yuan; Ma, Hon-Ming; Liau, Jiann-Jong; Yeh, Chuan-Ren; Huang, Chun-Hsiung

    2007-09-01

    Polyethylene wear of bearing components is the most common long-term complication in total knee arthroplasty. One would anticipate differing kinematics would generate different wear patterns (including wear type, degree, and symmetry) on the articulating surface of mobile-bearing and fixed-bearing inserts. Because mobile-bearing designs facilitate movement of the insert relative to the tray when the knee rotates, we hypothesized mobile-bearing designs would reduce the incidence of rotational asymmetric wear. We examined 51 worn tibial inserts, including 15 from mobile-bearing rotating-platform posterior-cruciate-sacrificing dished prostheses and 36 from fixed-bearing posterior-cruciate-retaining flat prostheses, which were retrieved at revision surgery with an average implantation time of 115 months. We divided wear types into low-grade wear (burnishing, abrasion, and cold flow) and high-grade wear (scratching, pitting, metal embedding, and delamination) to assess wear degree of polyethylene. To assess symmetry of wear, the insert surface was divided into medial and lateral sides and each side was further divided into three equal zones along the anteroposterior direction. Low-grade wear was more common in mobile-bearing knees, whereas high-grade wear was more common in fixed-bearing knees. We identified no internal/external rotational asymmetric wear or anteroposterior asymmetric wear in mobile-bearing knees.

  17. [Navigated implantation of total knee endoprostheses--a comparative study with conventional instrumentation].

    PubMed

    Jenny, J Y; Boeri, C

    2001-01-01

    A navigation system should improve the quality of a total knee prosthesis implantation in comparison to the classical, surgeon-controlled operative technique. The authors have implanted 40 knee total prostheses with an optical infrared navigation system (Orthopilot AESCULAP, Tuttlingen--group A). The quality of implantation was studied on postoperative long leg AP and lateral X-rays, and compared to a control group of 40 computer-paired total knee prostheses o the same model (Search Prosthesis, AESCULAP, Tuttlingen) implanted with a classical, surgeon-controlled technique (group B). An optimal mechanical femorotibial angle (3 degrees valgus to 3 degrees varus) was obtained by 33 cases in group A and 31 cases in group B (p > 0.05). Better results were seen for the coronal and sagittal orientation of both tibial and femoral components in group A. Globally, 26 cases of the group A and 12 cases of the group B were implanted in an optimal manner for all studied criteria (p < 0.01). The used navigation system allows a significant improvement of the quality of implantation of a knee total prosthesis in comparison to a classical, surgeon-controlled instrumentation. Long-term outcome could be consequently improved.

  18. [Partial replacement of the knee joint with patient-specific instruments and implants (ConforMIS iUni, iDuo)].

    PubMed

    Beckmann, J; Steinert, A; Zilkens, C; Zeh, A; Schnurr, C; Schmitt-Sody, M; Gebauer, M

    2016-04-01

    Knee arthroplasty is a successful standard procedure in orthopedic surgery; however, approximately 20 % of patients are dissatisfied with the clinical results as they suffer pain and can no longer achieve the presurgery level of activity. According to the literature the reasons are inexact fitting of the prosthesis or too few anatomically formed implants resulting in less physiological kinematics of the knee joint. Reducing the number of dissatisfied patients and the corresponding number of revisions is an important goal considering the increasing need for artificial joints. In this context, patient-specific knee implants are an obvious alternative to conventional implants. For the first time implants are now matched to the individual bone and not vice versa to achieve the best possible individual situation and geometry and more structures (e.g. ligaments and bone) are preserved or only those structures are replaced which were actually destroyed by arthrosis. According to the authors view, this represents an optimal and pioneering addition to conventional implants. Patient-specific implants and the instruments needed for correct alignment and fitting can be manufactured by virtual 3D reconstruction and 3D printing based on computed tomography (CT) scans. The portfolio covers medial as well as lateral unicondylar implants, medial as well as lateral bicompartmental implants (femorotibial and patellofemoral compartments) and cruciate ligament-preserving as well as cruciate ligament-substituting total knee replacements; however, it must be explicitly emphasized that the literature is sparse and no long-term data are available.

  19. Prolonged incubation time does not increase sensitivity for the diagnosis of implant-related infection using samples prepared by sonication of the implants.

    PubMed

    Esteban, J; Alvarez-Alvarez, B; Blanco, A; Fernández-Roblas, R; Gadea, I; Garcia-Cañete, J; Sandoval, E; Valdazo, M

    2013-07-01

    We have designed a prospective study to evaluate the usefulness of prolonged incubation of cultures from sonicated orthopaedic implants. During the study period 124 implants from 113 patients were processed (22 osteosynthetic implants, 46 hip prostheses, 54 knee prostheses, and two shoulder prostheses). Of these, 70 patients had clinical infection; 32 had received antibiotics at least seven days before removal of the implant. A total of 54 patients had sonicated samples that produced positive cultures (including four patients without infection). All of them were positive in the first seven days of incubation. No differences were found regarding previous antibiotic treatment when analysing colony counts or days of incubation in the case of a positive result. In our experience, extending incubation of the samples to 14 days does not add more positive results for sonicated orthopaedic implants (hip and knee prosthesis and osteosynthesis implants) compared with a conventional seven-day incubation period.

  20. Assessing the Relative Contributions of Active Ankle and Knee Assistance to the Walking Mechanics of Transfemoral Amputees Using a Powered Prosthesis

    PubMed Central

    Simon, Ann M.; Hargrove, Levi J.

    2016-01-01

    Powered knee-ankle prostheses are capable of providing net-positive mechanical energy to amputees. Yet, there are limitless ways to deliver this energy throughout the gait cycle. It remains largely unknown how different combinations of active knee and ankle assistance affect the walking mechanics of transfemoral amputees. This study assessed the relative contributions of stance phase knee swing initiation, increasing ankle stiffness and powered plantarflexion as three unilateral transfemoral amputees walked overground at their self-selected walking speed. Five combinations of knee and ankle conditions were evaluated regarding the kinematics and kinetics of the amputated and intact legs using repeated measures analyses of variance. We found eliminating active knee swing initiation or powered plantarflexion was linked to increased compensations of the ipsilateral hip joint during the subsequent swing phase. The elimination of knee swing initiation or powered plantarflexion also led to reduced braking ground reaction forces of the amputated and intact legs, and influenced both sagittal and frontal plane loading of the intact knee joint. Gradually increasing prosthetic ankle stiffness influenced the shape of the prosthetic ankle plantarflexion moment, more closely mirroring the intact ankle moment. Increasing ankle stiffness also corresponded to increased prosthetic ankle power generation (despite a similar maximum stiffness value across conditions) and increased braking ground reaction forces of the amputated leg. These findings further our understanding of how to deliver assistance with powered knee-ankle prostheses and the compensations that occur when specific aspects of assistance are added/removed. PMID:26807889

  1. Combined registration of 3D tibia and femur implant models in 3D magnetic resonance images

    NASA Astrophysics Data System (ADS)

    Englmeier, Karl-Hans; Siebert, Markus; von Eisenhart-Rothe, Ruediger; Graichen, Heiko

    2008-03-01

    The most frequent reasons for revision of total knee arthroplasty are loosening and abnormal axial alignment leading to an unphysiological kinematic of the knee implant. To get an idea about the postoperative kinematic of the implant, it is essential to determine the position and orientation of the tibial and femoral prosthesis. Therefore we developed a registration method for fitting 3D CAD-models of knee joint prostheses into an 3D MR image. This rigid registration is the basis for a quantitative analysis of the kinematics of knee implants. Firstly the surface data of the prostheses models are converted into a voxel representation; a recursive algorithm determines all boundary voxels of the original triangular surface data. Secondly an initial preconfiguration of the implants by the user is still necessary for the following step: The user has to perform a rough preconfiguration of both remaining prostheses models, so that the fine matching process gets a reasonable starting point. After that an automated gradient-based fine matching process determines the best absolute position and orientation: This iterative process changes all 6 parameters (3 rotational- and 3 translational parameters) of a model by a minimal amount until a maximum value of the matching function is reached. To examine the spread of the final solutions of the registration, the interobserver variability was measured in a group of testers. This variability, calculated by the relative standard deviation, improved from about 50% (pure manual registration) to 0.5% (rough manual preconfiguration and subsequent fine registration with the automatic fine matching process).

  2. Introduction of a new mobile-bearing total knee prosthesis: minimum three year follow-up of an RCT comparing it with a fixed-bearing device.

    PubMed

    Beard, D J; Pandit, H; Price, A J; Butler-Manuel, P A; Dodd, C A F; Murray, D W; Goodfellow, J W

    2007-12-01

    As part of the step-wise validation of a new prosthesis (TMK), we previously published the 1 year results of a randomised controlled trial in patients undergoing bilateral knee replacement [Price A., Rees J., Beard D., Juszczak E. et al. A mobile-bearing total knee prosthesis compared with a fixed-bearing prosthesis. JBJS B 2003;85-B-1:62-7.]. Forty patients had the new mobile-bearing prosthesis implanted in one knee and an established fixed-bearing device in the other (AGC). We now report the 3 year status of these patients and, in addition, review a separate multi-centre cohort of 172 patients who had undergone unilateral arthroplasty with the TMK. No significant differences were found in outcome (American Knee Society Score and Oxford Knee Score) between the two prostheses. The greater incidence of "clicking" in the mobile-bearing knee, reported in the previous review, persisted (TMK=48%, AGC=30%). The presence of this mechanical noise was found to have no relationship with outcome in either of the prostheses. The unilateral cohort study showed an acceptable complication rate for the new prosthesis, although some patients reported subjective instability. The method of controlled introduction of the TMK, of which this constitutes a further step, has allowed us to assess the significance of a reported problem (clicking) and to provide scientific data from which other surgeons can decide about use of the implant.

  3. Acoustic emission studies of posterior stabilized and cruciate retaining knee arthroplasties.

    PubMed

    Schwarzkopf, Ran; Kummer, Frederick J; Jaffe, William L

    2011-09-01

    Different acoustic frequencies have been used to diagnose progression of osteoarthritis, gross pathology, and wear in knee prostheses. It is possible that detailed analysis of higher frequencies could detect and quantify the smaller geometric changes (asperities) that develop in articular prosthetic wear. In this study we evaluated the feasibility of using ultrasonic emission to determine total knee arthroplasty (TKA) type and time from implantation using a simple, handheld measurement system. We examined the ultrasound emission generated by similar designs of posterior stabilized (PS) and cruciate retaining (CR) total knee prostheses and native knees of 58 patients and 10 controls. The subjects were asked to sit, rise, sit again, and take five steps while recording the acoustic data from both knees. Acoustic emission analysis examined frequency distributions and power spectrums of the recorded signals, and their relations to prosthesis type and time from implantation. We screened 44 CR and 48 PS TKAs, as well as 24 native knees. Analysis of this data suggested a possibility of differentiating between type of implants, and a relation to time since implantation. Our data suggest that we might be able to assess the status and time from implantation of a TKA by acoustic emission signals. Further in vitro analysis of the relationship of wear to ultrasonic emission data are needed for accurate quantification of arthroplasty wear. A simple, in-office screening tool for TKA patients could indicate which patients require closer follow-up and monitoring due to risk of potential problems.

  4. A comparison of clinical- and patient-reported outcomes of the cemented ATTUNE and PFC sigma fixed bearing cruciate sacrificing knee systems in patients who underwent total knee replacement with both prostheses in opposite knees.

    PubMed

    Carey, Brian W; Harty, James

    2018-03-15

    The ATTUNE Knee by DePuy Synthes was introduced in 2013. It is designed to provide better range of motion and address patient-reported instability. The PFC Sigma Knee, an earlier prosthesis by DePuy Synthes, is a common knee replacement with a strong clinical track record. Our aim is to compare the outcomes after primary total knee replacement for end-stage knee osteoarthritis of the PFC and ATTUNE knee systems in 21 patients who each have prosthesis in opposite knees using WOMAC, Oxford Knee and SF-12 scores and evaluation of range of motion. A review was carried out on 21 patients who underwent primary total knee replacement with both the ATTUNE and PFC knee systems. These were staged operations performed in the same institution and by the same surgeon. All cases were followed up for a minimum of 6 months. WOMAC, Oxford Knee and SF-12 scores, as well as knee range of motion were recorded preoperatively and at 6 months postoperatively. There was a significant difference in pre- to 6-month post-operative outcomes in PFC and ATTUNE groups with regard to improvement in range of motion (10° ± 8 and 13° ± 11, respectively). There was also a significant improvement in WOMAC scores (PFC group) and Oxford Knee Scores (ATTUNE group) (8.9 ± 7.7 and 12.1 ± 8.4, respectively). There was a significant improvement in SF-12 Score in both groups (10.1 ± 9.3 for PFC and 15.8 ± 13.3 for ATTUNE). The minimum clinically important difference (MCID) in scoring systems at 6 months was reached by 6 patients in the PFC group and 12 in the ATTUNE group. A significant difference was demonstrated in clinical outcome at 6 months postoperatively between PFC and ATTUNE knee systems in patients who underwent total knee arthroplasty with both prostheses. Superior results were recorded for the ATTUNE knee system.

  5. Extra-articular osteotomy for malunited unicondylar fractures of the proximal phalanx.

    PubMed

    Harness, Neil G; Chen, Alvin; Jupiter, Jesse B

    2005-05-01

    To evaluate an extra-articular osteotomy rather than an intra-articular osteotomy in the treatment of malunited unicondylar fractures of the proximal phalanx. An extra-articular osteotomy was used to correct the deformity resulting from a malunion of a unicondylar fracture of the proximal phalanx in 5 patients. A closing wedge osteotomy that was stabilized with tension band fixation accomplished realignment of the joint. Each patient was evaluated at a minimum of 1 year after surgery for radiographic healing, correction of angulation, digital motion, postoperative complications, current level of pain with motion, and overall satisfaction with the procedure. All of the osteotomies healed by 10 to 12 weeks after surgery with an average angular correction from 25 degrees to 1 degrees . The average proximal interphalangeal joint motion improved to 86 degrees from the preoperative average of 40 degrees , whereas the average total digital motion improved from 154 degrees before surgery to 204 degrees at follow-up evaluation. This method of extra-articular osteotomy for malunited unicondylar fractures of the proximal phalanx is highly reproducible, avoids the risks of intra-articular surgery, and leads to a predictable outcome.

  6. Medial unicondylar knee arthroplasty combined to anterior cruciate ligament reconstruction.

    PubMed

    Ventura, Alberto; Legnani, Claudio; Terzaghi, Clara; Iori, Stefano; Borgo, Enrico

    2017-03-01

    The purpose of the present study was to retrospectively evaluate the outcomes of patients who underwent combined medial unicompartmental knee arthroplasty (UKA) and anterior cruciate ligament (ACL) reconstruction. The hypothesis was that this procedure would lead to a high success rate in patients affected by isolated medial unicompartmental osteoarthritis and concomitant ACL deficiency. Fourteen patients with primary ACL lesion and concomitant medial compartment symptomatic osteoarthritis treated from 2006 to 2010 were followed up for an average time of 26.7 months (SD 4.2). Assessment included KOOS score, Oxford Knee score, American Knee Society scores, WOMAC index of osteoarthritis, Tegner activity level and objective examination including instrumented laxity test with KT-1000 arthrometer. Radiological assessment was done with standard simple radiographs in order to get information about any presence of loosening of the components. KOOS score, OKS, WOMAC index and the AKSS improved significantly after surgery (p < 0.001). Regarding AKSS, improvement was noted both in the objective score and in the functional one (p < 0.001). There was no clinical evidence of instability in any of the knees as evaluated with clinical laxity testing. No pathologic radiolucent lines were observed around the components. In one patient signs of osteoarthritis in the lateral compartment were observed 28 months after surgery. UKA combined with ACL reconstruction is a valid therapeutic option for the treatment of combined medial unicompartmental knee osteoarthritis and ACL deficiency in young and active patients and confirms subjective and objective clinical improvement 2 years after surgery. The use of a fixed-bearing prosthesis represents a reliable feature as it allows to overcome problems of improper ligament tensioning during the implantation of the components. IV.

  7. Wear analysis and finishing of bioceramic implant surfaces.

    PubMed

    Denkena, Berend; Reichstein, Martin; van der Meer, Marijke; Ostermeier, Sven; Hurschler, Christof

    2008-01-01

    A primary cause for revision operations of joint replacements is the implant loosening, due to immune reactions resulting from the agglomeration of polyethylene wear debris. Motivated by the successful application of bioceramic materials in hip joint prostheses, a trend towards the development of hard implant materials has occurred. Nonetheless in the area of total knee arthroplasty (TKA), modern efforts have still utilized polyethylene as the tibial-inlay joint component. The use of bioceramic hard-hard-pairings for total knee arthroplasty has been prevented by the complex kinematics and geometries required. Ceramics cannot cope with non-uniform loads, which suggests the need for new designs appropriate to the material. Furthermore, biomechanical requirements should be considered. A rolling-gliding wear simulator, which reproduces the movements and stresses of the knee joint on specimens of simplified geometry, has therefore been developed. High-precision machining processes for free formed bioceramic surfaces, with suitable grinding and polishing tools which adjust to constantly changing contact conditions, are essential. The goal is to put automated finishing in one clamping with five simultaneous controlled axes into practice. The developed manufacturing technologies will allow the advantageous bioceramic materials to be applied and accepted for more complex joint replacements such as knee prostheses.

  8. Dual-energy CT and ceramic or titanium prostheses material reduce CT artifacts and provide superior image quality of total knee arthroplasty.

    PubMed

    Kasparek, Maximilian F; Töpker, Michael; Lazar, Mathias; Weber, Michael; Kasparek, Michael; Mang, Thomas; Apfaltrer, Paul; Kubista, Bernd; Windhager, Reinhard; Ringl, Helmut

    2018-06-07

    To evaluate the influence of different scan parameters for single-energy CT and dual-energy CT, as well as the impact of different material used in a TKA prosthesis on image quality and the extent of metal artifacts. Eight pairs of TKA prostheses from different vendors were examined in a phantom set-up. Each pair consisted of a conventional CoCr prosthesis and the corresponding anti-allergic prosthesis (full titanium, ceramic, or ceramic-coated) from the same vendor. Nine different (seven dual-energy CT and two single-energy CT) scan protocols with different characteristics were used to determine the most suitable CT protocol for TKA imaging. Quantitative image analysis included assessment of blooming artifacts (metal implants appear thicker on CT than they are, given as virtual growth in mm in this paper) and streak artifacts (thick dark lines around metal). Qualitative image analysis was used to investigate the bone-prosthesis interface. The full titanium prosthesis and full ceramic knee showed significantly fewer blooming artifacts compared to the standard CoCr prosthesis (mean virtual growth 0.6-2.2 mm compared to 2.9-4.6 mm, p < 0.001). Dual-energy CT protocols showed less blooming (range 3.3-3.8 mm) compared to single-energy protocols (4.6-5.5 mm). The full titanium and full ceramic prostheses showed significantly fewer streak artifacts (mean standard deviation 77-86 Hounsfield unit (HU)) compared to the standard CoCr prosthesis (277-334 HU, p < 0.001). All dual-energy CT protocols had fewer metal streak artifacts (215-296 HU compared to single-energy CT protocols (392-497 HU)). Full titanium and ceramic prostheses were ranked superior with regard to the image quality at the bone/prosthesis interface compared to a standard CoCr prosthesis, and all dual-energy CT protocols were ranked better than single-energy protocols. Dual-energy CT and ceramic or titanium prostheses reduce CT artifacts and provide superior image quality of total knee arthroplasty at the bone/prosthesis interface. These findings support the use of dual-energy CT as a solid imaging base for clinical decision-making and the use of full-titanium or ceramic prostheses to allow for better CT visualization of the bone-prosthesis interface.

  9. Post-Cam Design and Contact Stress on Tibial Posts in Posterior-Stabilized Total Knee Prostheses: Comparison Between a Rounded and a Squared Design.

    PubMed

    Watanabe, Toshifumi; Koga, Hideyuki; Horie, Masafumi; Katagiri, Hiroki; Sekiya, Ichiro; Muneta, Takeshi

    2017-12-01

    The post-cam mechanism in posterior stabilized (PS) prostheses plays an important role in total knee arthroplasty (TKA). The purpose of this study is to clarify the difference of the contact stress on the tibial post between a rounded post-cam design and a squared design during deep knee flexion and at hyperextension using the three-dimensional (3D) finite element models. We created 2 types of 3D, finite element models of PS prostheses (types A and B), whose surfaces were identical except for the post-cam geometries: type A has a rounded post-cam design, while type B has a squared design. Both types have a similar curved-shape intercondylar notch of the femoral component. Stress distributions, peak contact stresses, and contact areas on the tibial posts at 90°, 120°, and 150° flexion with/without 10° tibial internal rotation and at 10° hyperextension were compared between the 2 models. Type B demonstrated more concentrated stress distribution compared to type A. The peak contact stresses were similar in both groups during neutral flexion; however, the stresses were much higher in type B during flexion with 10° rotation and at hyperextension. The higher peak contact stresses corresponded to the smaller contact areas in the tibial post. A rounded post-cam design demonstrated less stress concentration during flexion with rotation and at hyperextension compared with a squared design. The results would be useful for development of implant designs and prediction of the contact stress on the tibial post in PS total knee arthroplasty. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Prosthetic knee design by simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hollerbach, K; Hollister, A

    1999-07-30

    Although 150,000 total knee replacement surgeries are performed annually in North America, current designs of knee prostheses have mechanical problems that include a limited range of motion, abnormal gait patterns, patellofemoral joint dysfunction, implant loosening or subsidence, and excessive wear. These problems fall into three categories: failure to reproduce normal joint kinematics, which results in altered limb function; bone-implant interface failure; and material failure. Modern computer technology can be used to design, prototype, and test new total knee implants. The design team uses the full range of CAD-CAM to design and produce implant prototypes for mechanical and clinical testing. Closermore » approximation of natural knee kinematics and kinetics is essential for improved patient function and diminished implant loads. Current knee replacement designs are based on 19th Century theories that the knee moves about a variable axis of rotation. Recent research has shown, however, that knee motion occurs about two fixed, offset axes of rotation. These aces are not perpendicular to the long axes of the bones or to each other, and the axes do not intersect. Bearing surfaces of mechanisms that move about axes of rotation are surfaces of revolution of those axes which advanced CAD technology can produce. Solids with surfaces of revolution for the two axes of rotation for the knee have been made using an HP9000 workstation and Structural Ideas Master Series CAD software at ArthroMotion. The implant's CAD model should closely replicate movements of the normal knee. The knee model will have a range of flexion-extension (FE) from -5 to 120 degrees. Movements include varus, valgus, internal and external rotation, as well as flexion and extension. The patellofemoral joint is aligned perpendicular to the FE axis and replicates the natural joint more closely than those of existing prostheses. The bearing surfaces will be more congruent than current designs and should generate lower stresses in the materials.« less

  11. Secondary patella resurfacing in painful non-resurfaced total knee arthroplasties : A study of survival and clinical outcome from the Norwegian Arthroplasty Register (1994-2011).

    PubMed

    Leta, Tesfaye H; Lygre, Stein Håkon L; Skredderstuen, Arne; Hallan, Geir; Gjertsen, Jan-Erik; Rokne, Berit; Furnes, Ove

    2016-04-01

    In Norway, 19 % of revisions of non-resurfaced total knee arthroplasties done for knee pain between 1994 and 2011 were Secondary Patella Resurfacing (SPR). It is, however, unclear whether SPR actually resolves the pain. The aim was to investigate prostheses survival and clinical outcomes following SPR. A total of 308 knees (301 patients) with SPR were used to assess implant survival, and a sub-cohort (n = 114 out of 301 patients) with Patient Reported Outcome Measures (PROMs) data were used to assess the clinical outcomes. The EuroQol (EQ-5D), the Knee Injury and Osteoarthritis Outcome Score, and Visual Analogue Scales on satisfaction and pain were used to collect PROM data. Outcomes were analysed by Kaplan-Meier, Cox regression, and multiple linear regression. The five- and ten-year Kaplan-Meier survival percentages were 91 % and 87 %, respectively. Overall, 35 knees were re-revised at a median follow-up of eight years and pain alone (10 knees) was the main cause of re-revision. Younger patients (<60 years) had nearly nine times higher risk of re-revision compared to older patients (>70 years) (RR = 8.6; p < 0.001). Mean EQ-5D index score had improved from 0.41 (SD 0.21) preoperative to 0.56 (SD 0.25) postoperative following SPR. A total of 63 % of patients with PROM data were satisfied with the outcomes of SPR. The long-term prostheses survival following SPR was satisfactory, although not as good as for primary knee replacement. Patients' health related quality of life improved significantly following SPR. Still, more than a third of patients with PROMs data were dissatisfied with the outcomes of the SPR procedure.

  12. A machine for the preliminary investigation of design features influencing the wear behaviour of knee prostheses.

    PubMed

    McGloughlin, T M; Murphy, D M; Kavanagh, A G

    2004-01-01

    Degradation of tibial inserts in vivo has been found to be multifactorial in nature, resulting in a complex interaction of many variables. A range of kinematic conditions occurs at the tibio-femoral interface, giving rise to various degrees of rolling and sliding at this interface. The movement of the tibio-femoral contact point may be an influential factor in the overall wear of ultra-high molecular weight polyethylene (UHMWPE) tibial components. As part of this study a three-station wear-test machine was designed and built to investigate the influence of rolling and sliding on the wear behaviour of specific design aspects of contemporary knee prostheses. Using the machine, it is possible to monitor the effect of various slide roll ratios on the performance of contemporary bearing designs from a geometrical and materials perspective.

  13. Different intraoperative kinematics with comparable clinical outcomes of ultracongruent and posterior stabilized mobile-bearing total knee arthroplasty.

    PubMed

    Kim, Tae Woo; Lee, Sang Min; Seong, Sang Cheol; Lee, Sahnghoon; Jang, Jak; Lee, Myung Chul

    2016-09-01

    There remains no consensus as to whether mobile total knee arthroplasty (TKA) should use a posterior cruciate ligament-sacrificing ultracongruent (UC) or a posterior cruciate ligament-substituting posterior stabilized (PS) prosthesis. The purpose of this study was to assess intraoperative kinematics and clinical outcomes of UC and PS rotating platform mobile-bearing TKA. In this randomized controlled study, mobile UC TKA prostheses (n = 45) were compared with mobile PS TKA prostheses (n = 45) with regard to intraoperative kinematics and clinical outcomes. The passive kinematic study using intraoperative navigation system included anterior/posterior translation, varus/valgus alignment and rotation of femur during flexion. The patients were clinically and radiographically evaluated over a 3-year follow-up. Paradoxical anterior translation of the femur was 10.8 ± 5.2 mm in the UC knee from 0° to 82° of knee flexion and 8.7 ± 3.0 mm in the PS knee from 0° to 70° of knee flexion (p = 0.027). Paradoxical internal rotation of the femur was 5.8° in the UC knees and 9.9° in the PS knees (p = 0.003). But, there was no significant difference between the groups in regard to the coronal alignment. There was no significant difference in the range of motion, KS knee scores, KS function scores, and WOMAC index scores. Despite different intraoperative kinematics between mobile UC and mobile PS TKA, neither design reproduced physiologic knee kinematics and there was no difference in clinical outcomes between the two groups. The clinical relevance of the study is that despite different intraoperative kinematics, UC design can be a considerable alternative to PS design in mobile-bearing TKA in respect of clinical outcomes. II.

  14. Comparison of mechanical energy profiles of passive and active below-knee prostheses: a case study.

    PubMed

    Takahashi, Kota Z; Horne, John R; Stanhope, Steven J

    2015-04-01

    With the recent technological advancements of prosthetic lower limbs, there is currently a great desire to objectively evaluate existing prostheses. Using a novel biomechanical analysis, the purpose of this case study was to compare the mechanical energy profiles of anatomical and two disparate prostheses: a passive prosthesis and an active prosthesis. An individual with a transtibial amputation who customarily wears a passive prosthesis (Elation, Össur) and an active prosthesis (BiOM, iWalk, Inc.) and 11 healthy subjects participated in an instrumented gait analysis. The total mechanical power and work of below-knee structures during stance were quantified using a unified deformable segment power analysis. Active prosthesis generated greater peak power and total positive work than passive prosthesis and healthy anatomical limbs. The case study will enhance future efforts to objectively evaluate prosthetic functions during gait in individuals with transtibial amputations. A prosthetic limb should closely replicate the mechanical energy profiles of anatomical limbs. The unified deformable (UD) analysis may be valuable to facilitate future clinical prescription and guide fine adjustments of prosthetic componentry to optimize gait outcomes. © The International Society for Prosthetics and Orthotics 2014.

  15. Revision rates after knee replacement. Cumulative results from worldwide clinical studies versus joint registers.

    PubMed

    Pabinger, C; Berghold, A; Boehler, N; Labek, G

    2013-02-01

    To assess revision rates after knee arthroplasty by comparing the cumulative results from worldwide clinical studies and arthroplasty registers. We hypothesised that the revision rate of all clinical studies of a given implant and register data would not differ significantly. A systematic review of clinical studies in indexed peer-reviewed journals was performed followed by internal and external validation. Parameters for measurement of revision were applied (Revision for any reason, Revisions per 100 observed component years). Register data served as control group. Thirty-six knee arthroplasty systems were identified to meet the inclusion criteria: 21 total knee arthroplasty (TKA) systems, 14 unicondylar knee arthroplasty (UKA) systems, one patello-femoral implant system. For 13 systems (36%), no published study was available that contained revision data. For 17 implants (47%), publications were available dealing with radiographic, surgical or technical details, but power was too weak to compare revision rates at a significant level. Six implant systems (17%) had a significant number of revisions published and were finally analysed. In general, developers report better results than independent users. Studies from developers represent an overproportional share of all observed component years. Register data report overall 10-year revision rates of TKA of 6.2% (range: 4.9-7.8%), rates for UKA are 16.5% (range: 9.7-19.6%). Revision rates of all clinical studies of a given implant do not differ significantly from register data. However, significant differences were found between the revision rates published by developers and register data. Therefore the different data need to be interpreted in the context of the source of the information. Copyright © 2012 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  16. Comparison of Customized Cutting Block and Conventional Cutting Instrument in Total Knee Arthroplasty: A Randomized Controlled Trial.

    PubMed

    Tammachote, Nattapol; Panichkul, Phonthakorn; Kanitnate, Supakit

    2018-03-01

    Customized cutting block (CCB) was designed to ensure the accurate alignment of knee prostheses during total knee arthroplasty. Given the paucity of CCB efficacy data, we compare CCB with conventional cutting guide using a randomized controlled trial. One hundred eight osteoarthritic knee patients underwent total knee arthroplasty by one experienced surgeon were randomized to receive CCB (n = 54) or conventional cutting instrument (CCI) surgery (n = 54). The primary outcomes were limb alignment, prostheses position, and operative time. The secondary outcomes were hemodynamic alteration after surgery, functional outcomes (modified Western Ontario and McMaster University Osteoarthritis Index) and range of motion at 2 years after surgery. Mean hip-knee-ankle angle in the CCB group was 179.4° ± 1.8° vs 179.1° ± 2.4° in the CCI group, Δ = 0 (95% confidence interval [CI] -0.6 to 1.1, P = .55). Mean operative time was faster in the CCB arm: 93 ± 12 vs 104 ± 12 minutes, Δ = 11 (95% CI -16.7 to -7.2, P < .0001). There were no differences in hemodynamic parameters, mean blood loss (446 [CCB] vs 514 mL [CCI], Δ = -68 [95% CI -138 to 31 mL, P = .21]), postoperative hemoglobin changes, incidence of hypotension (systolic <90 mm Hg), oliguria, and rates of blood transfusion. Functional outcomes and range of motion were also similar. There was no improvement in alignment, hemodynamic changes, blood loss, and knee functional outcomes. CCB reduced surgical time by 11 minutes in our population. CCB cost-effectiveness should be further investigated. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. UNICOMPARTMENTAL KNEE ARTHROPLASTY: CURRENT PERSPECTIVES AND TRENDS IN BRAZIL

    PubMed Central

    Arliani, Gustavo Gonçalves; Júnior, João Alberto Yazigi; Angelini, Felipe Bertelli; Ferlin, Fernando; Hernandes, Andrea Canizares; Astur, Diego da Costa; Cohen, Moises

    2015-01-01

    Objective: The aim of this study was to evaluate the approaches and procedures used by Brazilian orthopedic surgeons for treating osteoarthrosis by means of unicompartmental knee arthroplasty and high tibial osteotomy of the knee. Methods: A questionnaire with 14 closed questions was developed and applied to Brazilian knee surgeons during the three days of the 43rd Brazilian Congress of Orthopedics and Traumatology. Results: A total of 113 surgeons filled out the questionnaire completely and became part of the sample analyzed. In this study, the majority of the surgeons performed fewer than five unicompartmental knee arthroplasty procedures/year (61.1%) and between 5 and 15 high tibial osteotomy procedures/year (37.2%). Use of computerized navigation systems during surgery remains uncommon in our environment, since only 0.9% of the specialists were using it. 65.5% of the surgeons reported that they had chosen to use total knee arthroplasty rather than partial arthroplasty due to lack of familiarity with the surgical technique. When asked about the possibility that the number of unicompartmental prostheses used in Brazil would grow as surgeons in this country become increasingly familiar with the technique, 80.5% of the respondents believed in this hypothesis. In this sample, we found that the greater the surgeon's experience was, the greater the numbers of unicompartmental prostheses and tibial osteotomies performed annually were (r = 0.550 and r = 0.465, respectively; p < 0.05). Conclusions: There is a clear evolutional trend towards treatment of unicompartmental osteoarthritis using partial knee arthroplasty in Brazil. However, further prospective controlled studies are needed in order to evaluate the clinical and scientific benefits of these trends. PMID:27047891

  18. Mobile-bearing total knee arthroplasty: a full traumatic rotation of 180°.

    PubMed

    Sudanese, Alessandra; Castiello, Emanuela; Affatato, Saverio

    2013-06-25

    From February 2008 to September 2012 we implanted 204 mobile-bearing knee prostheses in 192 patients. All the prostheses were cemented (both femoral and tibial components), and the patella was not replaced. Only one early complication of the implants (1/204 = 0.004%) occurred after a traumatic event as a full 180° rotation of the mobile-bearing polyethylene insert. A 78-year-old woman presented with swelling and severe pain at her right knee. This traumatic event was the only case among our mobile-bearing insert patients. 
The failed polyethylene inserts were retrieved and studied using a scanning electron microscope (SEM, ZEISS EVO 50 EP, Cambridge, UK) operating at 20 kV. 
Scratching and pitting were found on the UHMWPE insert perpendicular to the machining tracks for the concave surface. SEM micrographs of the insert showed burnishing on the concave surfaces and longitudinal scratches were clearly detectable and well-marked on the analyzed surfaces. 
A traumatic, fully rotating, polyethylene insert is rare and our case is the first report describing a traumatic event with a complete 180 degree rotation mobile-bearing in a total knee prosthesis. 
In the literature few reports discuss clinical outcomes after total knee arthroplasty in patients with Parkinson's disease and they cite mixed results. However, some authors suggest that posterior-stabilized and cruciate-retaining TKA should work well while others prefer cruciate-retaining, condylar constrained kinetics, or hinged devices. Although we did not implant a posterior-stabilized mobile-bearing total knee prosthesis or a constrained prosthesis, we obtained good clinical and radiological results at the 2-year followup.

  19. Asian-specific total knee system: 5-14 year follow-up study.

    PubMed

    Hosaka, Kunihiro; Saito, Shu; Ishii, Takao; Mori, Sei; Sumino, Takanobu; Tokuhashi, Yasuaki

    2011-11-02

    Knee size and body size differ in Asians compared with Caucasians. Nevertheless, many total knee arthroplasty (TKA) prostheses used worldwide are made for Western Caucasian subjects. As a result, an Asian's knee might not fit these prostheses. We studied the Flexible Nichidai Knee (FNK) system, a new model of TKA for Asian patients. The purpose of this report is to investigate the outcomes of this prosthesis retrospectively. We investigated 1055 primary TKAs in 595 patients who underwent FNK for osteoarthritis (OA) in Japan and were followed for > 5 years. The knee score and function score were used for clinical evaluation. We examined the range of motion (ROM) preoperatively and at final follow-up and radiographic assessments. In addition, postoperative complications were investigated. A survivorship analysis was also conducted using two endpoints: revision for any reason and aseptic failure. 890 knees in 502 patients were available for study (follow-up rate of 96.0%). The mean follow-up term was 8.3 years (range, 5.0-14.1 years). The knee and function score significantly improved from 41.3 to 90.3 and from 39.1 to 76.2 points, respectively (p < 0.001). The mean ROM in FNK posterior cruciate retaining (CR) type and FNK posterior-stabilized (PS) type ameliorated significantly from 107.8° and 95.6° to 110.7° and 110.4°, respectively (p < 0.01). Ten knees underwent revision surgery (infection in 3 cases, instability in 2, loosening in 2, and non-union of femoral supracondylar fracture, severe pain, and recurrent hemarthrosis in 1 each). The survivorship rate was 99.4% (95% CI, 99.0-99.8) at 5 years (n = 952 patients at risk) and 96.2% (95% CI, 91.9-100) at 12.5 years (n = 49 patients at risk). The FNK prosthesis for Asians achieved excellent mid- to long-term survivorship and clinical results.

  20. State of the art review on design and manufacture of hybrid biomedical materials: Hip and knee prostheses.

    PubMed

    Bahraminasab, Marjan; Farahmand, Farzam

    2017-09-01

    The trend in biomaterials development has now headed for tailoring the properties and making hybrid materials to achieve the optimal performance metrics in a product. Modern manufacturing processes along with advanced computational techniques enable systematical fabrication of new biomaterials by design strategy. Functionally graded materials as a recent group of hybrid materials have found numerous applications in biomedical area, particularly for making orthopedic prostheses. This article, therefore, seeks to address the following research questions: (RQ1) What is the desired structure of orthopedic hybrid materials? (RQ2) What is the contribution of the literature in the development of hybrid materials in the field of orthopedic research? (RQ3) Which type of manufacturing approaches is prevalently used to build these materials for knee and hip implants? (RQ4) Is there any inadequacy in the methods applied?

  1. [Posturographic study of total prostheses in the leg. Apropos of 88 patients examined].

    PubMed

    Lord, G; Gentaz, R; Gagey, P M; Baron, J B

    1976-01-01

    By suppressing certain articular sensory receptors, the reconstructive surgery of joints using total prostheses modifies tonic postural activity and, by this means, alters the regulation of balance in the subjects of operation. This doubtless explains certain discrepancies between the apparently excellent results in respect of joint movement and muscle strength and poor utilisation of the joint in every day life (instability, use of sticks or failure to use the joint in walking). Drawing on the experience and basic work of specialists in posture, the authors have undertaken a study of tonic postural activity in patients who had received a total prosthesis in the lower limb, both from the clinical aspect and by graphic measurement using an electronic apparatus, the statokinesiometer. Fourteen normal subjects were tested to calibrate the apparatus and 8 patients suffering from established osteoarthritis of the hip were studied as controls. Analysis of tonic postural activity was made in 66 patients who had received total prostheses in the lower limb. The results showed significant disturbance in balance in ankle prostheses, minimal disturbance in knee prostheses and not significant disturbance in hip prostheses. Certain therapeutic implications are derived from this study.

  2. Componentry for lower extremity prostheses.

    PubMed

    Friel, Karen

    2005-09-01

    Prosthetic components for both transtibial and transfemoral amputations are available for patients of every level of ambulation. Most current suspension systems, knees, foot/ankle assemblies, and shock absorbers use endoskeletal construction that emphasizes total contact and weight distribution between bony structures and soft tissues. Different components offer varying benefits to energy expenditure, activity level, balance, and proprioception. Less dynamic ambulators may use fixed-cadence knees and non-dynamic response feet; higher functioning walkers benefit from dynamic response feet and variable-cadence knees. In addition, specific considerations must be kept in mind when fitting a patient with peripheral vascular disease or diabetes.

  3. Comparison between the C-leg microprocessor-controlled prosthetic knee and non-microprocessor control prosthetic knees: a preliminary study of energy expenditure, obstacle course performance, and quality of life survey.

    PubMed

    Seymour, Ron; Engbretson, Brenda; Kott, Karen; Ordway, Nathaniel; Brooks, Gary; Crannell, Jessica; Hickernell, Elise; Wheeler, Katie

    2007-03-01

    This study investigated energy expenditure and obstacle course negotiation between the C-leg and various non-microprocessor control (NMC) prosthetic knees and compared a quality of life survey (SF-36v2) of use of the C-leg to national norms. Thirteen subjects with unilateral limb loss (12 with trans-femoral and one with a knee disarticulation amputation) participated in the study. The mean age was 46 years, range 30-75. Energy expenditure using both the NMC and C-leg prostheses was measured at self-selected typical and fast walking paces on a motorized treadmill. Subjects were also asked to walk through a standardized walking obstacle course carrying a 4.5 kg (10 lb) basket and with hands free. Finally, the SF-36v2 was completed for subjects while using the C-leg. Statistically significant differences were found in oxygen consumption between prostheses at both typical and fast paces with the C-leg showing decreased values. Use of the C-leg resulted in a statistically significant decrease in the number of steps and time to complete the obstacle course. Scores on a quality of life index for subjects using the C-leg were above the mean for norms for limitation in the use of an arm or leg, equal to the mean for the general United States population for the physical component score and were above this mean for the mental component score. Based on oxygen consumption and obstacle course findings, the C-leg when compared to the NMC prostheses may provide increased functional mobility and ease of performance in the home and community environment. Questionnaire results suggest a minimal quality of life impairment when using a C-leg for this cohort of individuals with amputation.

  4. Does a conservative tibial cut in conventional total knee arthroplasty violate the deep medial collateral ligament?

    PubMed

    Maes, Michael; Luyckx, Thomas; Bellemans, Johan

    2014-11-01

    Based on the anatomy of the deep medial collateral ligament (MCL), it was hypothesized that at least part of its cross-sectional insertion area is jeopardized while performing a standard tibial cut in conventional total knee arthroplasty (TKA). The aim of this study was to determine whether it is anatomically possible to preserve the tibial deep MCL insertion during conventional TKA. Thirty-three unpaired cadaveric knee specimens were used for this study. Knees with severe varus/valgus deformity or damage to the medial structures of the knee were excluded. In the first part of the study, the dimensions of the tibial insertion of the deep MCL and its relationship to the joint line were recorded. Next, the cross-sectional area of the deep MCL insertion was determined using calibrated digital photographic analysis. In the second part, the effect of a standard 9-mm 3° sloped tibial cut on the structural integrity of the deep MCL cross-sectional insertion area was determined using conventional instrumentation. The proximal border of the deep MCL insertion site on the tibia was located on average 4.7 ± 1.2 mm distally to the joint line. After performing a standard 9-mm 3° sloped tibial cut, on average 54% of the deep MCL insertion area was resected. In 29% of the cases, the deep MCL insertion area was completely excised. The deep MCL cannot routinely be preserved in conventional TKA. The deep MCL insertion is at risk and may be jeopardized in case of a tibial cut 9 mm below the native joint line. As the deep MCL is a distinct medial stabilizer and plays an important role in rotational stability, this may have implications in future designs of both unicondylar and total knee arthroplasty, but further research is necessary.

  5. Rapid Molecular Microbiologic Diagnosis of Prosthetic Joint Infection

    PubMed Central

    Cazanave, Charles; Greenwood-Quaintance, Kerryl E.; Hanssen, Arlen D.; Karau, Melissa J.; Schmidt, Suzannah M.; Gomez Urena, Eric O.; Mandrekar, Jayawant N.; Osmon, Douglas R.; Lough, Lindsay E.; Pritt, Bobbi S.; Steckelberg, James M.

    2013-01-01

    We previously showed that culture of samples obtained by prosthesis vortexing and sonication was more sensitive than tissue culture for prosthetic joint infection (PJI) diagnosis. Despite improved sensitivity, culture-negative cases remained; furthermore, culture has a long turnaround time. We designed a genus-/group-specific rapid PCR assay panel targeting PJI bacteria and applied it to samples obtained by vortexing and sonicating explanted hip and knee prostheses, and we compared the results to those with sonicate fluid and periprosthetic tissue culture obtained at revision or resection arthroplasty. We studied 434 subjects with knee (n = 272) or hip (n = 162) prostheses; using a standardized definition, 144 had PJI. Sensitivities of tissue culture, of sonicate fluid culture, and of PCR were 70.1, 72.9, and 77.1%, respectively. Specificities were 97.9, 98.3, and 97.9%, respectively. Sonicate fluid PCR was more sensitive than tissue culture (P = 0.04). PCR of prosthesis sonication samples is more sensitive than tissue culture for the microbiologic diagnosis of prosthetic hip and knee infection and provides same-day PJI diagnosis with definition of microbiology. The high assay specificity suggests that typical PJI bacteria may not cause aseptic implant failure. PMID:23658273

  6. Long-term clinical outcomes and survivorship of press-fit condylar sigma fixed-bearing and mobile-bearing total knee prostheses in the same patients.

    PubMed

    Kim, Young-Hoo; Park, Jang-Won; Kim, Jun-Shik; Kulkarni, Sourabh S; Kim, Yoon-Hong

    2014-10-01

    We are aware of no study that has compared press-fit condylar Sigma fixed-bearing and mobile-bearing total knee prostheses in the same patients after more than ten years of follow-up. The purpose of the current study was to compare these two implants with respect to the functional and radiographic results, prevalence of osteolysis, and overall revision rates at a mean of 12.1 years of follow-up. The study consisted of a consecutive series of 444 patients (mean age [and standard deviation], 66.5 ± 7.4 years) who underwent simultaneous bilateral total knee arthroplasty, with one side treated immediately after the other. All of the patients received a press-fit condylar Sigma mobile-bearing prosthesis on one side and a press-fit condylar Sigma fixed-bearing prosthesis on the contralateral side. The minimum duration of follow-up was ten years (mean, 12.1 years; range, ten to thirteen years). At the time of each follow-up visit, the patients were assessed clinically and radiographically. Postoperative total knee scores (95 and 94 points), Western Ontario and McMaster Universities Osteoarthritis Index (19 and 18 points), University of California, Los Angeles activity score (both prostheses, 5 points), range of motion (129° ± 6.3° and 127° ± 6.8°), and radiographic findings did not differ significantly between the press-fit condylar Sigma mobile and fixed-bearing designs at the final follow-up. The prevalence of aseptic loosening (1.4% and 1.8%) did not differ significantly between the mobile and fixed-bearing implant designs. No knee in either group had osteolysis. The estimated survival rate with revision as the end point was 98.2% (95% confidence interval, 91% to 99%) and 97.5% (95% confidence interval, 91% to 99%) at 12.1 years for the mobile and fixed-bearing implant groups, respectively. The results of the present long-term clinical study suggest that excellent clinical and radiographic results were achieved with both the press-fit condylar Sigma mobile and fixed-bearing cruciate-retaining total knee designs. We found no significant clinical advantage for a mobile-bearing over a fixed-bearing total knee prosthesis. Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

  7. Simultaneous mobile- and fixed-bearing total knee replacement in the same patients. A prospective comparison of mid-term outcomes using a similar design of prosthesis.

    PubMed

    Kim, Y-H; Kim, D-Y; Kim, J-S

    2007-07-01

    We conducted a randomised prospective study to evaluate the clinical and radiological results of a mobile- and fixed-bearing total knee replacement of similar design in 174 patients who had bilateral simultaneous knee replacement. The mean follow-up was for 5.6 years (5.2 to 6.1). The total knee score, pain score, functional score and range of movement were not statistically different (p > 0.05) between the two groups. Osteolysis was not seen in any knee in either group. Two knees (1%) in the mobile-bearing group required revision because of infection; none in the fixed-bearing group needed revision. Excellent results can be achieved with both mobile- and fixed-bearing prostheses of similar design at mid-term follow-up. We could demonstrate no significant clinical advantage for a mobile bearing.

  8. Patient-specific instrumentation improves alignment of lateral unicompartmental knee replacements by novice surgeons.

    PubMed

    Ng, Chin Ting Justin; Newman, Simon; Harris, Simon; Clarke, Susannah; Cobb, Justin

    2017-07-01

    Patient-specific instrumentation (PSI) has the potential to offer numerous benefits-not least of all, improved resection accuracy; but its potential has not been realised in clinical studies. An explanation may be the focus of such studies on the total knee replacement (TKR-a common procedure, with which surgeons are generally very familiar. Consequently, we sought to investigate the potential role of PSI in guiding novice surgeons to perform the more technically demanding and less familiar lateral unicondylar knee replacement (LUKR). Twelve orthopaedic trainees naive to LUKR were instructed to perform the procedure according to a pre-operative plan. These were carried out on synthetic sawbones and were completed once with conventional instrumentation alone and once with the adjunct of PSI, allowing a comparison of the plan adherence achieved by the two sets of instrumentation. There was a tendency for PSI to demonstrate improved plan adherence, though a statistically significant improvement was only seen in compound rotational error of the femoral implant (p = 0.004). PSI was, however, able to produce narrower standard deviations in the mean translational displacement of the femoral implant and also the mean rotational displacement of both implants, suggesting a higher degree of precision. Our study provides some evidence that PSI can improve the ability of novice surgeons to replicate a pre-operative plan, but our results suggest the need for larger-scale clinical studies to establish the role of PSI in this procedure.

  9. Effect of lavage and brush preparation on cement penetration and primary stability in tibial unicompartmental total knee arthroplasty: An experimental cadaver study.

    PubMed

    Scheele, Christian; Pietschmann, Matthias F; Schröder, Christian; Grupp, Thomas; Holderied, Melanie; Jansson, Volmar; Müller, Peter E

    2017-03-01

    Unicompartmental total knee arthroplasty (UKA) is a well-established treatment option for unicondylar osteoarthritis, and generally leads to better functional results than tricompartimental total knee arthroplasty (TKA). However, revision rates of UKAs are reported as being higher; a major reason for this is aseptic loosening of the tibial component due to implant-cement-bone interface fatigue. The objective of this study was to determine the effects of trabecular bone preparation, prior to implantation of tibial UKAs, on morphological and biomechanical outcomes in a cadaver study. Cemented UKAs were performed in 18 human cadaver knees after the bone bed was cleaned using pulsed lavage (Group A), conventional brush (Group B) or no cleaning at all (Group C, control). Morphologic cement penetration and primary stability were measured. The area proportion under the tibial component without visible cement penetration was significantly higher in Group C (21.9%, SD 11.9) than in both Group A (7.1%, SD 5.8), and Group B (6.5%, SD 4.2) (P=0.007). The overall cement penetration depth did not differ between groups. However, in the posterior part, cement penetration depth was significantly higher in Group B (1.9mm, SD 0.3) than in both Group A (1.3mm, SD 0.3) and Group C (1.4mm, SD 0.3) (P=0.015). The mode of preparation did not show a substantial effect on primary stability tested under dynamic compression-shear test conditions (P=0.910). Bone preparation significantly enhances cement interdigitation. The application of a brush shows similar results compared with the application of pulsed lavage. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. In vitro kinematic measurements of the patellar tendon in two different types of posterior-stabilized total knee arthroplasties.

    PubMed

    Zhu, Zhonglin; Ding, Hui; Dang, Xiao; Tang, Jing; Zhou, Yixin; Wang, Guangzhi

    2010-01-01

    Fixed-bearing posterior-stabilized (PS) total knee arthroplasty (TKA) has been used in Asian countries for several years, but few studies have investigated differences in the kinematic properties of the patellar tendon after standard PS TKA as compared to high-flex PS TKA. To quantify the in vitro three-dimensional (3D) kinematics of the patellar tendon during passive high flexion and full extension before and after two different types of PS TKAs. Six fresh-frozen cadaveric knees were tested under the following conditions: the unaltered state, status-post traditional PS prostheses (Simth-nephew GENESIS II) replacement, and status-post high-flexion PS prostheses replacement. The soft tissue around the knee and the quadriceps muscle were preserved, then tested under the load of a specific weight in an Oxford knee rig. We designed a specialized rigid body with four active markers fixed to each bone to track the 3D passive motion of the cadaveric knees. Flexion and extension was controlled by the knee rig and captured by an Optotrak Certus high precision optical tracking system. The attachment sites of the patellar tendon were registered as virtual markers to calculate the 3D kinematics. The patellar tendon of the unaltered knee and both TKA knees showed similar deformation. We found the length of the patellar tendon changed significantly during a motion from full extension to 30°, but there was no significant change in length while undergoing a motion from 30° to full flexion. Both the sagittal plane and coronal plane angles of the patellar tendon decreased after PS TKAs. There was no significant difference in patellar tendon kinematics between the two types of PS TKAs. We believe the changes observed in the sagittal plane and coronal plane angles of the patellar tendon after PS TKAs may influence the extensor mechanism and be an important cause of patella-femoral complications. These data may be used to assess patella-femoral complications after surgery so as to improve the design of high-flexion TKAs for Asians and achieve long-term stability.

  11. Gait asymmetry of transfemoral amputees using mechanical and microprocessor-controlled prosthetic knees.

    PubMed

    Kaufman, Kenton R; Frittoli, Serena; Frigo, Carlo A

    2012-06-01

    Amputees walk with an asymmetrical gait, which may lead to future musculoskeletal degenerative changes. The purpose of this study was to compare the gait asymmetry of active transfemoral amputees while using a passive mechanical knee joint or a microprocessor-controlled knee joint. Objective 3D gait measurements were obtained in 15 subjects (12 men and 3 women; age 42, range 26-57). Research participants were longtime users of a mechanical prosthesis (mean 20 years, range 3-36 years). Joint symmetry was calculated using a novel method that includes the entire waveform throughout the gait cycle. There was no significant difference in hip, knee and ankle kinematics symmetry when using the different knee prostheses. In contrast, the results demonstrated a significant improvement in lower extremity joint kinetics symmetry when using the microprocessor-controlled knee. Use of the microprocessor-controlled knee joint resulted in improved gait symmetry. These improvements may lead to a reduction in the degenerative musculoskeletal changes often experienced by amputees. Copyright © 2011 Elsevier Ltd. All rights reserved.

  12. Preliminary Evaluation of a Diagnostic Tool for Prosthetics

    DTIC Science & Technology

    2017-10-01

    volume change. Processing algorithms for data from the activity monitors were modified to run more efficiently so that large datasets could be...left) and blade style prostheses (right). Figure 4: Ankle ActiGraph correct position demonstrated for a left leg below-knee amputee cylindrical

  13. Implant use for primary hip and knee arthroplasty: are we getting it right first time?

    PubMed

    Ng Man Sun, Stephen; Gillott, Elizabeth; Bhamra, Jagmeet; Briggs, Tim

    2013-06-01

    Implants used for hip and knee arthroplasties have recently come under increased scrutiny. In England, a large variety of prostheses are currently being used. With the need for savings within the NHS of up to £20 billion over the next five years, we should be 'getting it right first time' by using the most reliable implants with proven survivorship. The 8th Annual Report from the NJR (2011) reporting on prostheses used in 2010 was analysed to determine whether implants had published survivorship data. This study demonstrates that the majority of implants did have long-term results but a small percentage had no published data. The cost of these implants was calculated to see if the implants provided best value for money based on survivorship. Implant choice was also correlated to revision rates published in the NJR report (2011) to help determine whether their continued use was justified. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. Negative pressures during swing phase in below-knee prostheses with rubber sleeve suspension.

    PubMed

    Chino, N; Pearson, J R; Cockrell, J L; Mikishko, H A; Koepke, G H

    1975-01-01

    Negative pressures in the small space between the distal stump and the below-knee prosthetic socket were measured during swing phase for a series of nine subjects. A molded rubber sleeve connecting the prosthesis and the thigh was found to enhance this effect so that suction suspension occurred during the entire swing phase. Deterioration of the suction occurred when the sleeve was intentionally pierced, and when other suspensions such as a suprapatellar cuff or thigh band were tested. The findings indicate that the total-contact socket, gel liner and elastic sleeve combine to create suction in the below-knee socket which improves overall comfort and function for the patient in using the prosthesis.

  15. Mobile bearing vs fixed bearing prostheses for posterior cruciate retaining total knee arthroplasty for postoperative functional status in patients with osteoarthritis and rheumatoid arthritis.

    PubMed

    Hofstede, Stefanie N; Nouta, Klaas Auke; Jacobs, Wilco; van Hooff, Miranda L; Wymenga, Ate B; Pijls, Bart G; Nelissen, Rob G H H; Marang-van de Mheen, Perla J

    2015-02-04

    It is unclear whether there are differences in benefits and harms between mobile and fixed prostheses for total knee arthroplasty (TKA). The previous Cochrane review published in 2004 included two articles. Many more trials have been performed since then; therefore an update is needed. To assess the benefits and harms of mobile bearing compared with fixed bearing cruciate retaining total knee arthroplasty for functional and clinical outcomes in patients with osteoarthritis (OA) or rheumatoid arthritis (RA). We searched The Cochrane Library, PubMed, EMBASE, CINAHL and Web of Science up to 27 February 2014, and the trial registers ClinicalTrials.gov, Multiregister, Current Controlled Trials and the World Health Organization (WHO) International Clinical Trials Registry Platform for data from unpublished trials, up to 11 February 2014. We also screened the reference lists of selected articles. We selected randomised controlled trials comparing mobile bearing with fixed bearing prostheses in cruciate retaining TKA among patients with osteoarthritis or rheumatoid arthritis, using functional or clinical outcome measures and follow-up of at least six months. We used standard methodological procedures as expected by The Cochrane Collaboration. We found 19 studies with 1641 participants (1616 with OA (98.5%) and 25 with RA (1.5%)) and 2247 knees. Seventeen new studies were included in this update.Quality of the evidence ranged from moderate (knee pain) to low (other outcomes). Most studies had unclear risk of bias for allocation concealment, blinding of participants and personnel, blinding of outcome assessment and selective reporting, and high risk of bias for incomplete outcome data and other bias. Knee painWe calculated the standardised mean difference (SMD) for pain, using the Knee Society Score (KSS) and visual analogue scale (VAS) in 11 studies (58%) and 1531 knees (68%). No statistically significant differences between groups were reported (SMD 0.09, 95% confidence interval (CI) -0.03 to 0.22, P value 0.15). This represents an absolute risk difference of 2.4% points higher (95% CI 0.8% lower to 5.9% higher) on the KSS pain scale and a relative percent change of 0.22% (95% CI 0.07% lower to 0.53% higher). The results were homogeneous. Clinical and functional scores The KSS clinical score did not differ statistically significantly between groups (14 studies (74%) and 1845 knees (82%)) with a mean difference (MD) of -1.06 points (95% CI -2.87 to 0.74, P value 0.25) and heterogeneous results. KSS function was reported in 14 studies (74%) with 1845 knees (82%) as an MD of -0.10 point (95% CI -1.93 to 1.73, P value 0.91) and homogeneous results. In two studies (11%), the KSS total score was favourable for mobile bearing (159 vs 132 for fixed bearing), with MD of -26.52 points (95% CI -45.03 to -8.01, P value 0.005), but with a wide 95% confidence interval indicating uncertainty about the estimate.Other reported scoring systems did not show statistically significant differences: Hospital for Special Surgery (HSS) score (seven studies (37%) in 1021 knees (45%)) with an MD of -1.36 (95% CI -4.18 to 1.46, P value 0.35); Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) total score (two studies (11%), 167 knees (7%)) with an MD of -4.46 (95% CI -16.26 to 7.34, P value 0.46); and Oxford total (five studies (26%), 647 knees (29%) with an MD of -0.25 (95% CI -1.41 to 0.91, P value 0.67). Health-related quality of lifeThree studies (16%) with 498 knees (22%) reported on health-related quality of life, and no statistically significant differences were noted between the mobile bearing and fixed bearing groups. The Short Form (SF)-12 Physical Component Summary had an MD of -1.96 (95% CI -4.55 to 0.63, P value 0.14) and heterogeneous results. Revision surgeryTwenty seven revisions (1.3%) were performed in 17 studies (89%) with 2065 knees (92%). In all, 13 knees were revised in the fixed bearing group and 14 knees in the mobile bearing group. No statistically significant differences were found (risk difference 0.00, 95% CI -0.01 to 0.01, P value 0.58), and homogeneous results were reported. MortalityIn seven out of 19 studies, 13 participants (37%) died. Two of these participants had undergone bilateral surgery, and for seven participants, it was unclear which prosthesis they had received; therefore they were excluded from the analyses. Thus our analysis included four out of 191 participants (2.1%) who had died: one in the fixed bearing group and three in the mobile bearing group. No statistically significant differences were found. The risk difference was -0.02 (95% CI -0.06 to 0.03, P value 0.49) and results were homogeneous. Reoperation ratesThirty reoperations were performed in 17 studies (89%) with 2065 knees (92%): 18 knees in the fixed bearing group (of the 1031 knees) and 12 knees in the mobile group (of the 1034 knees). No statistically significant differences were found. The risk difference was -0.01 (95% CI -0.01 to 0.01, P value 0.99) with homogeneous results. Other serious adverse eventsSixteen studies (84%) reported nine other serious adverse events in 1735 knees (77%): four in the fixed bearing group (of the 862 knees) and five in the mobile bearing group (of the 873 knees). No statistically significant differences were found (risk difference 0.00, 95% CI -0.01 to 0.01, P value 0.88), and results were homogeneous. Moderate- to low-quality evidence suggests that mobile bearing prostheses may have similar effects on knee pain, clinical and functional scores, health-related quality of life, revision surgery, mortality, reoperation rate and other serious adverse events compared with fixed bearing prostheses in posterior cruciate retaining TKA. Therefore we cannot draw firm conclusions. Most (98.5%) participants had OA, so the findings primarily reflect results reported in participants with OA. Future studies should report in greater detail outcomes such as those presented in this systematic review, with sufficient follow-up time to allow gathering of high-quality evidence and to inform clinical practice. Large registry-based studies may have added value, but they are subject to treatment-by-indication bias. Therefore, this systematic review of RCTs can be viewed as the best available evidence.

  16. Articulating spacers used in two-stage revision of infected hip and knee prostheses abrade with time.

    PubMed

    Fink, Bernd; Rechtenbach, Annett; Büchner, Hubert; Vogt, Sebastian; Hahn, Michael

    2011-04-01

    Articulating spacers used in two-stage revision surgery of infected prostheses have the potential to abrade and subsequently induce third-body wear of the new prosthesis. We asked whether particulate material abraded from spacers could be detected in the synovial membrane 6 weeks after implantation when the spacers were removed for the second stage of the revision. Sixteen hip spacers (cemented prosthesis stem articulating with a cement cup) and four knee spacers (customized mobile cement spacers) were explanted 6 weeks after implantation and the synovial membranes were removed at the same time. The membranes were examined by xray fluorescence spectroscopy, xray diffraction for the presence of abraded particles originating from the spacer material, and analyzed in a semiquantitative manner by inductively coupled plasma mass spectrometry. Histologic analyses also were performed. We found zirconium dioxide in substantial amounts in all samples, and in the specimens of the hip synovial lining, we detected particles that originated from the metal heads of the spacers. Histologically, zirconium oxide particles were seen in the synovial membrane of every spacer and bone cement particles in one knee and two hip spacers. The observations suggest cement spacers do abrade within 6 weeks. Given the presence of abrasion debris, we recommend total synovectomy and extensive lavage during the second-stage reimplantation surgery to minimize the number of abraded particles and any retained bacteria.

  17. An Investigation into a Gear-Based Knee Joint Designed for Lower Limb Prosthesis.

    PubMed

    Bhuiyan, M S H; Choudhury, I A; Dahari, M; Nukman, Y; Dawal, S Z

    2017-01-01

    A gear-based knee joint is designed to improve the performance of mechanical-type above-knee prostheses. The gear set with the help of some bracing, and bracket arrangement, is used to enable the prosthesis to follow the residual limb movement. The motion analysis and finite-element analysis (FEA) of knee joint components are carried out to assess the feasibility of the design. The maximum stress of 29.74 MPa and maximum strain of 2.393e-004 are obtained in the gear, whereas the maximum displacement of 7.975 mm occurred in the stopper of the knee arrangement. The factor of safety of 3.5 obtained from the FE analysis indicated no possibility of design failure. The results obtained from the FE analysis are then compared with the real data obtained from the literature for a similar subject. The pattern of motion analysis results has shown a great resemblance with the gait cycle of a healthy biological limb.

  18. An Investigation into a Gear-Based Knee Joint Designed for Lower Limb Prosthesis

    PubMed Central

    2017-01-01

    A gear-based knee joint is designed to improve the performance of mechanical-type above-knee prostheses. The gear set with the help of some bracing, and bracket arrangement, is used to enable the prosthesis to follow the residual limb movement. The motion analysis and finite-element analysis (FEA) of knee joint components are carried out to assess the feasibility of the design. The maximum stress of 29.74 MPa and maximum strain of 2.393e−004 are obtained in the gear, whereas the maximum displacement of 7.975 mm occurred in the stopper of the knee arrangement. The factor of safety of 3.5 obtained from the FE analysis indicated no possibility of design failure. The results obtained from the FE analysis are then compared with the real data obtained from the literature for a similar subject. The pattern of motion analysis results has shown a great resemblance with the gait cycle of a healthy biological limb. PMID:28584518

  19. CKS knee prosthesis: biomechanics and clinical results in 42 cases.

    PubMed

    Martucci, E; Verni, E; Del Prete, G; Stulberg, S D

    1996-01-01

    From 1991 to 1993 a total of 42 CKS prostheses were implanted for the following reasons: osteoarthrosis (34 cases), rheumatoid arthritis (7 cases) tibial necrosis (1 case). At follow-up obtained after 17 to 41 months the results were: excellent or good: 41; the only poor result was probably related to excessive tension of the posterior cruciate ligament. 94% of the patients reported complete regression of pain, 85% was capable of going up and down stairs without support. Mean joint flexion was 105 degrees. Radiologically the anatomical axis of the knee had a mean valgus of anatomical axis of the knee had a mean valgus of 6 degrees. The prosthetic components were always cemented. The posterior cruciate ligament was removed in 7 knees, so that the prosthesis with "posterior stability" was used. The patella was never prosthetized. One patient complained of peri-patellar pain two months after surgery which then regressed completely.

  20. Joint registries as continuous surveillance systems: the experience of the Catalan Arthroplasty Register (RACat).

    PubMed

    Allepuz, Alejandro; Martínez, Olga; Tebé, Cristian; Nardi, Joan; Portabella, Frederic; Espallargues, Mireia

    2014-03-01

    The aim was to present results on prosthesis performance in Catalonia for the period 2005-2010. All publicly funded hospitals submit in an electronic format data on hip and knee arthroplasties: patients' insurance identification number, hospital, joint (hip/knee), type of arthroplasty (primary/revision), side (right/left), date of surgery and prosthesis (manufacturer name and catalogue number). A standard survival analysis based on Kaplan-Meier estimation was carried out. Fifty-two hospitals have sent information to the RACat which has data on 36,951 knee and 26,477 hip arthroplasties. Cumulative prostheses revision risks at 3 years were 3.3% (95% CI: 3.1-3.6) for knee, 2.9% (95% CI: 2.5-3.3) for total hip and 2.5% (95% CI: 2.0-3.1) for partial hip. When compared to other registries a higher risk of revision was observed. © 2013.

  1. Revision of a Fractured Uncemented Revision Stem Using a Custom Designed Punch and Retrograde Through-Knee Approach

    PubMed Central

    Nasr, P. J.; Keene, G. S.

    2015-01-01

    We report a unique case of a fractured modular cobalt chromium connection taper Revitan (Zimmer, Warsaw, IN) revision prosthesis. Macroscopic examination revealed a fracture at the diaphyseal-metaphyseal junction of this modular component. This report highlights that fractures can still occur with modern modular prostheses. We are not aware of any published failures of the Revitan revision prosthesis. We also describe a unique method of retrieval for a broken well fixed uncemented femoral stem, using a custom designed extraction instrument via a through-knee approach. PMID:25793134

  2. Model-Based Estimation of Knee Stiffness

    PubMed Central

    Pfeifer, Serge; Vallery, Heike; Hardegger, Michael; Riener, Robert; Perreault, Eric J.

    2013-01-01

    During natural locomotion, the stiffness of the human knee is modulated continuously and subconsciously according to the demands of activity and terrain. Given modern actuator technology, powered transfemoral prostheses could theoretically provide a similar degree of sophistication and function. However, experimentally quantifying knee stiffness modulation during natural gait is challenging. Alternatively, joint stiffness could be estimated in a less disruptive manner using electromyography (EMG) combined with kinetic and kinematic measurements to estimate muscle force, together with models that relate muscle force to stiffness. Here we present the first step in that process, where we develop such an approach and evaluate it in isometric conditions, where experimental measurements are more feasible. Our EMG-guided modeling approach allows us to consider conditions with antagonistic muscle activation, a phenomenon commonly observed in physiological gait. Our validation shows that model-based estimates of knee joint stiffness coincide well with experimental data obtained using conventional perturbation techniques. We conclude that knee stiffness can be accurately estimated in isometric conditions without applying perturbations, which presents an important step towards our ultimate goal of quantifying knee stiffness during gait. PMID:22801482

  3. BIOENERGETIC DIFFERENCES DURING WALKING AND RUNNING IN TRANSFEMORAL AMPUTEE RUNNERS USING ARTICULATING AND NON-ARTICULATING KNEE PROSTHESES

    PubMed Central

    Highsmith, M. Jason; Kahle, Jason T.; Miro, Rebecca M.; Mengelkoch, Larry J.

    2016-01-01

    Transfemoral amputation (TFA) patients require considerably more energy to walk and run than non-amputees. The purpose of this study was to examine potential bioenergetic differences (oxygen uptake (VO2), heart rate (HR), and ratings of perceived exertion (RPE)) for TFA patients utilizing a conventional running prosthesis with an articulating knee mechanism versus a running prosthesis with a non-articulating knee joint. Four trained TFA runners (n = 4) were accommodated to and tested with both conditions. VO2 and HR were significantly lower (p ≤ 0.05) in five of eight fixed walking and running speeds for the prosthesis with an articulating knee mechanism. TFA demonstrated a trend for lower RPE at six of eight walking speeds using the prosthesis with the articulated knee condition. A trend was observed for self-selected walking speed, self-selected running speed, and maximal speed to be faster for TFA subjects using the prosthesis with the articulated knee condition. Finally, all four TFA participants subjectively preferred running with the prosthesis with the articulated knee condition. These findings suggest that, for trained TFA runners, a running prosthesis with an articulating knee prosthesis reduces ambulatory energy costs and enhances subjective perceptive measures compared to using a non-articulating knee prosthesis. PMID:28066524

  4. Clinical Outcome of Medial Pivot Compared With Press-Fit Condylar Sigma Cruciate-Retaining Mobile-Bearing Total Knee Arthroplasty.

    PubMed

    Kim, Young-Hoo; Park, Jang-Won; Kim, Jun-Shik

    2017-10-01

    The purpose of this study was to compare the long-term clinical results, radiographic results, range of knee motion, patient satisfaction, and the survival rate of Medial-Pivot posterior cruciate-substituting, knee prosthesis and a press-fit condylar (PFC) Sigma cruciate-retaining mobile-bearing knee prosthesis in the same patients. One hundred eighty-two patients received Medial-Pivot knee prosthesis in one knee and a PFC Sigma knee prosthesis in the contralateral knee. The minimum duration of follow-up was 11 years (range, 11-12.6 years). The knees with a Medial-Pivot knee prosthesis had significantly worse results than those with a PFC Sigma knee prosthesis at the final follow-up with regard to the mean postoperative Knee Society knee scores (90 compared with 95 points), Western Ontario and McMaster Universities Osteoarthritis Index score (25 compared with 18 points), and range of knee motion (117° compared with 128°). Patients were more satisfied with PFC Sigma knee prosthesis (93%) than with Medial-Pivot knee prosthesis (75%). Complication rates were significantly higher in the Medial-Pivot knee group (26%) than those in the PFC Sigma knee group (6.5%). Radiographic results and survival rates (99% compared with 99.5%) were similar between the 2 groups. Although the long-term fixation and survival rate of both Medial-Pivot and PFC Sigma prostheses were similar, we observed a worse knee score, worse range of knee motion, and patient satisfaction was less in the Medial-Pivot knee group than in the PFC Sigma knee group. Furthermore, complication rate was also higher in the Medial-Pivot knee group than the other group. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Loosening of the total knee arthroplasty: detection by radionuclide bone scanning. [/sup 99m/Tc-methylene diphosphonate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hunter, J.C.; Hattner, R.S.; Murray, W.R.

    1980-07-01

    Pain after total knee arthroplasty is a common clinical problem in orthopedics, and prosthetic loosening, often requiring surgical revision, is usually the etiology. Since standard clinical and radiographic diagnostic measures have not proven totally satisfactory, a study of the utility of bone scintigraphy to assess stability of the knee prosthesis was done. Thirty-five patients with 39 prostheses were studied. Seventeen patients with 21 total knee arthroplasties served as controls and were asymptomatic, were stable at surgery, or improved with conservative management. Eighteen knees in 18 symptomatic patients composed the experimental group. Of these, 11 knees were loose at surgery andmore » seven have had surgery recommended. Scintigrams of the knees were obtained using /sup 99m/Tc-MDP, and ranked 0-3 corresponding to increasingly abnormal localization by three observers. Highly significant differences were observed between the abnormal and control groups (p<0.001). Reciprocal changes in sensitivity and specificity with increasingly stringent criteria were shown. While it is apparent that the bone scan cannot be used as the sole diagnostic method for evaluation of prosthetic stability, it does seem to be a useful adjunct along with clinical criteria and radiographic studies.« less

  6. [Total and unicompartmental knee replacement. Patient-specific Instrumentation].

    PubMed

    Köster, G; Biró, C

    2016-04-01

    The objective of patient-specific instrumentation (PSI Zimmer®) technology is to optimize positioning and selection of components as well as surgical procedure in uni- and bicompartimental knee replacement. The article contains a description of the planning and surgical technique and evaluates the method based on own results and literature. Using MRI or CT scans a virtual 3D model of the joint is created in order to simulate and plan the implant positioning. According to these data, pin placement and/or cutting guides are produced, which enable the surgeon to transfer the planning to the surgical procedure. In a prospective comparative study 88 patients (44 per each of the two techniques) were operated by one surgeon receiving the same TKA using either MRI-based PSI or a conventional technique. The number of surgical trays, operating time, intraoperative changes and frontal alignment using a full leg x‑ray (70 cases) were compared. In 17 patients the method was applied with unicondylar knee replacement. Anatomical abnormalities could be detected preoperatively and considered during the operation. With PSI the number of trays could be reduced and predictability of the component size was more precise. Intraoperative changes became necessary only for distal femoral (25 %) and proximal tibial (36 %) resection and tibial rotation (40 %). Alignment was more precise in the PSI cases PSI using the applied technique proved to be practicable and reliable. The advantages of precise planning became obvious. Results concerning alignment are inconsistent in the literature. Soft tissue balancing has only been included in the technique to a limited degree so far. PSI is still in an early stage of development and further development opportunities should be exploited before final assessment.

  7. Safety and function of a prototype microprocessor-controlled knee prosthesis for low active transfemoral amputees switching from a mechanic knee prosthesis: a pilot study.

    PubMed

    Hasenoehrl, Timothy; Schmalz, Thomas; Windhager, Reinhard; Domayer, Stephan; Dana, Sara; Ambrozy, Clemens; Palma, Stefano; Crevenna, Richard

    2018-02-01

    Aim of this pilot study was to assess safety and functioning of a microprocessor-controlled knee prosthesis (MPK) after a short familiarization time and no structured physical therapy. Five elderly, low-active transfemoral amputees who were fitted with a standard non-microprocessor controlled knee prosthesis (NMPK) performed a baseline measurement consisting of a 3 D gait analysis, functional tests and questionnaires. The first follow-up consisted of the same test procedure and was performed with the MPK after 4 to 6 weeks of familiarization. After being refitted to their standard NMPK again, the subjects undertook the second follow-up which consisted of solely questionnaires 4 weeks later. Questionnaires and functional tests showed an increase in the perception of safety. Moreover, gait analysis revealed more physiologic knee and hip extension/flexion patterns when using the MPK. Our results showed that although the Genium with Cenior-Leg ruleset-MPK (GCL-MPK) might help to improve several safety-related outcomes as well as gait biomechanics the functional potential of the GCL-MPK may have been limited without specific training and a sufficient acclimation period. Implications for Rehabilitation Elderly transfemoral amputees are often limited in their activity by safety issues as well as insufficient functioning regarding the non microprocessor-controlled knee prostheses (NMPK), thing that could be eliminated with the use of suitable microprocessor-controlled prostheses (MPK). The safety and functioning of a prototype MPK (GCL-MPK) specifically designed for the needs of older and low-active transfemoral amputees was assessed in this pilot study. The GCL-MPK showed indicators of increased safety and more natural walking patterns in older and low-active transfemoral amputees in comparison to the standard NMPK already after a short acclimatisation time and no structured physical therapy. Regarding functional performance it seems as if providing older and low-active transfemoral amputees with the GCL-MPK alone without prescribing structured prosthesis training might be insufficient to achieve improvements over the standard NMPKs.

  8. Alternatives to amputation.

    PubMed Central

    Lendrum, J.

    1980-01-01

    Alternatives to conventional skin flap cover for limb wounds extend both the number and type of defects which can now be closed with reconstruction of both form and function for patients who might otherwise come to amputation. The old adage that where a sinus leads to dead or foreign material it can only be closed after removal of that dead or foreign material is no longer true. The number of patients coming to above-knee amputation after prosthetic replacement of the knee joint could be reduced by muscle flap cover of exposed arthroplasty prostheses. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 PMID:7377695

  9. Bone Repair and Military Readiness

    DTIC Science & Technology

    2012-10-25

    formation. Orthopedic surgeons have had to adapt surgical techniques to account for issues with cementing total joint prostheses and subsequent total joint ...the silorane composite has the potential to support osseous integration around the cemented total joint implant and may generate less immunogenic wear...factors, and potential for osseointegration/osseoinduction, this material has potential to be used for screw augmentation, total hip/knee joint

  10. Total knee arthroplasty in limbs affected by poliomyelitis.

    PubMed

    Giori, Nicholas J; Lewallen, David G

    2002-07-01

    Little information is available regarding the results and complications of total knee arthroplasty in limbs affected by poliomyelitis with severe knee degeneration. We performed a retrospective chart and radiograph review of patients with a history of poliomyelitis involving a limb that subsequently underwent primary total knee arthroplasty between 1970 and 2000. Sixteen total knee arthroplasties were performed in limbs affected by poliomyelitis in fifteen patients. Eleven patients were followed for a minimum of two years, one (two knees) died before the minimum two-year follow-up could be completed, and three were followed for less than two years. No patient was lost to follow-up. There were two periprosthetic fractures, one peroneal nerve palsy, one avulsion of the patellar tendon, and four cases of recurrent instability. These complications were related to the poor bone quality, valgus deformity, patella baja, poor musculature, and attenuated soft tissues commonly found in knees affected by poliomyelitis. Knee Society pain and knee scores were improved postoperatively for all nine knees with a two-year follow-up that had had at least antigravity quadriceps strength prior to surgery. However, Knee Society function scores remained at 0 or worsened for six of the eleven knees followed for at least two years, including those with less than antigravity strength, and four of the nine knees with at least antigravity strength. None of the prostheses loosened. Pain and knee scores improved following total knee arthroplasty in patients with a history of poliomyelitis and antigravity quadriceps strength, but there was less pain relief in patients with less than antigravity quadriceps strength. Recurrence of instability and progressive functional deterioration is possible in all knees affected by poliomyelitis that have undergone total knee replacement, but they appear to occur more commonly in more severely affected knees.

  11. Total Knee Replacement

    PubMed Central

    2005-01-01

    Executive Summary Objective The aim of this review was to assess the effectiveness, in terms of pain reduction and functional improvement, and costing of total knee replacement (TKR) for people with osteoarthritis for whom less invasive treatments (such as physiotherapy, analgesics, anti-inflammatory drugs, intra-articular steroids, hyaluronic acids, and arthroscopic surgery) have failed. Clinical Need Osteoarthritis affects an estimated 10% to 12% of Canadian adults. The therapeutic goals of osteoarthritis treatment are to improve joint mobility and reduce pain. Stepwise treatment options include exercise, weight loss, physiotherapy, analgesics, anti-inflammatory drugs, intra-articular steroids and hyaluronic acids, arthroscopic surgery, and, in severe cases, total joint replacement with follow-up rehabilitation. These treatments are delivered by a range of health care professionals, including physiotherapists, occupational therapists, family physicians, internists, rheumatologists, and orthopedic surgeons. TKR is an end-of-line treatment for patients with severe pain and functional limitations. More women than men undergo knee replacement, and most patients are between 55 and 84 years old. The Technology TKR is a surgical procedure in which an artificial joint or prosthesis replaces a damaged knee joint. The primary indication for TKR is pain, followed by functional limitation. Usually, a person’s daily activities must be substantially affected by pain and functional limitations for him or her to be considered a candidate for TKR. There are 3 different types of knee replacement prostheses. Non-constrained prostheses use the patient’s ligaments and muscles to provide the stability for the prosthesis. Semi-constrained prostheses provide some stability for the knee and do not rely entirely on the patient’s ligaments and muscles to provide the stability. Constrained prostheses are for patients whose ligaments and muscles are not able to provide stability for the knee prosthesis. The most common risks and complications associated with TKR are deep venous thrombosis, infection, stiffness, loosening, and osteolysis. To prevent deep venous thrombosis, patients are treated with heparin prophylactically and/or given support stockings to wear. Patients are also given antibiotics for 24 hours after surgery to minimize the risk of infection. Stiffness is another associated complication. In most patients, it can be avoided by keeping the knee moving in the days and weeks following surgery. The National Institutes of Health in the United States concluded that the indications for TKR should include the following: radiological evidence of joint damage, moderate to severe persistent pain that is not adequately relieved by nonsurgical management, and clinically significant functional limitation resulting in diminished quality of life. Review Strategy In March 2005, the following databases were searched: Cochrane Library International Agency for Health Technology Assessment (first quarter 2005), Cochrane Database of Systematic Reviews (first quarter 2005), Cochrane Central Register of Controlled Trials (first quarter 2005), MEDLINE (1966 to March 2005), MEDLINE In-Process and Other Non-indexed Citations (1966 to March 14, 2005), and EMBASE (1980 to 2005 week 9). The Medical Advisory Secretariat also searched Medscape on the Internet for recent reports on trials that were unpublished but that were presented at international conferences. In addition, the Web site Current Controlled Trials (www.controlled-trials.com) was searched for ongoing trials investigating TKR or unicompartmental knee replacement. No studies were identified that compared TKR to an alternative treatment. Several studies have been reported that compare preoperative measurement scores on targeted measures of functioning and pain to postoperative measurement scores in patients undergoing various TKR procedures. In order for the Medical Advisory Secretariat to measure the effectiveness of TKR and to compare the effectiveness of TKR across studies, effect sizes were calculated in studies that reported the standard deviations of the preoperative and postoperative measurement scores. Percent change was also calculated. For this review, a 20% improvement in outcome score was defined as the minimal clinically important difference. Summary of Findings Overall, patients who undergo TKR surgery for osteoarthritis have substantial improvements in terms of reduction of pain and improvement of function. A comparison of the mean effect score and the percent change in 19 studies that reported preoperative and postoperative outcome scores for patients who had TKR showed that the procedure is effective. The 19 studies included patients of various ages and used a variety of prostheses and techniques to implant the device. TKR was effective in all of the studies. The revision rates ranged from 0% to 13% in the studies that reported at least 5 years of follow-up. As for the factors that predict TKR outcomes, a variety of factors have been evaluated, including obesity, age, gender, prosthesis design, and surgical techniques; however, none of these have been shown to predict outcomes (pain or function) consistently across studies. However, the regression analyses identified accounted for only 12% to 27% of the variance, indicating that over 70% of the variance in the outcomes of TKR is unexplained. In terms of the timing of TKR surgery, 2 studies found that the severity of osteoarthritis does not predict outcome, but 1 study was found that higher functioning patients had significantly less pain and better function up to 2 years after surgery compared with lower functioning patients. It is important to note that the patients in the low and high function groups were evenly matched on comorbid conditions. Unicompartmental knee replacement surgery seems to be as effective as TKR surgery for people who meet the indications for it. This is a subset of people who have osteoarthritis of the knee, because for unicompartmental knee replacement to be indicated, only 1 (usually the medial) compartment of the knee can be affected. Patients who undergo this kind of surgery seem to have shorter hospital stays and faster recovery times than do patients who have TKR surgery. Conclusion There is substantial evidence to indicate that TKR effectively reduces pain and improves function. PMID:23074478

  12. Learning curve for new technology?: a nationwide register-based study of 46,363 total knee arthroplasties.

    PubMed

    Peltola, Mikko; Malmivaara, Antti; Paavola, Mika

    2013-12-04

    The risk of early revision is increased for the first patients operatively treated with a newly introduced knee prosthesis. In this study, we explored the learning curves associated with ten knee implant models to determine their effect on early revision risk. We studied register data from all seventy-five surgical units that performed knee arthroplasty in Finland from 1998 to 2007. Of 54,925 patients (66,098 knees), 39,528 patients (46,363 knees) underwent arthroplasty for osteoarthritis of the knee with the ten most common total knee implants and were followed with complete data until December 31, 2010, or the time of death. We used a Cox proportional-hazards regression model for calculating the hazard ratios for early revision for the first fifteen arthroplasties and subsequent increments of numbers of arthroplasties. We found large differences among knee implants at the introduction with regard to the risk of early revision, as well as for the overall risk of early revision. A learning curve was found for four implant models, while six models did not show a learning effect on the risk of early revision. The survivorship of the studied prostheses showed substantial differences. Knee implants have model-specific learning curves and early revision risks. Some models are more difficult to implement than others. The manufacturers should consider the learning effect when designing implants and instrumentation. The surgeons should thoroughly familiarize themselves with the new knee implants before use.

  13. Rapidly growing non-tuberculous mycobacteria infection of prosthetic knee joints: A report of two cases.

    PubMed

    Kim, Manyoung; Ha, Chul-Won; Jang, Jae Won; Park, Yong-Beom

    2017-08-01

    Non-tuberculous mycobacteria (NTM) cause prosthetic knee joint infections in rare cases. Infections with rapidly growing non-tuberculous mycobacteria (RGNTM) are difficult to treat due to their aggressive clinical behavior and resistance to antibiotics. Infections of a prosthetic knee joint by RGNTM have rarely been reported. A standard of treatment has not yet been established because of the rarity of the condition. In previous reports, diagnoses of RGNTM infections in prosthetic knee joints took a long time to reach because the condition was not suspected, due to its rarity. In addition, it is difficult to identify RGNTM in the lab because special identification tests are needed. In previous reports, after treatment for RGNTM prosthetic infections, knee prostheses could not be re-implanted in all cases but one, resulting in arthrodesis or resection arthroplasty; this was most likely due to the aggressiveness of these organisms. In the present report, two cases of prosthetic knee joint infection caused by RGNTM (Mycobacterium abscessus) are described that were successfully treated, and in which prosthetic joints were finally reimplanted in two-stage revision surgery. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. [Bone cement adhesion on ceramic surfaces - surface activation of retention surfaces of knee prostheses by atmospheric plasma versus thermal surface treatment].

    PubMed

    Marx, B; Marx, R; Reisgen, U; Wirtz, D

    2015-04-01

    CoCrMo alloys are contraindicated for allergy sufferers. For these patients, uncemented and cemented prostheses made of titanium alloy are indicated. Knee prostheses machined from that alloy, however, may have poor tribological behaviour, especially in relation to UHMWPE inlays. Therefore, for knee replacement cemented high-strength oxide ceramic prostheses are suitable for allergy sufferers and in cases of particle-induced aseptic loosening. For adhesion of bone cement, the ceramic surface, however, only exposes inefficient mechanical retention spots as compared with a textured metal surface. Undercuts generated by corundum blasting which in the short-term are highly efficient on a CoCrMo surface are not possible on a ceramic surface due to the brittleness of ceramics. Textures due to blasting may initiate cracks which will weaken the strength of a ceramic prosthesis. Due to the lack of textures mechanical retention is poor or even not existent. Micromotions are promoted and early aseptic loosening is predictable. Instead silicoating of the ceramic surface will allow specific adhesion and result in better hydrolytic stability of bonding thereby preventing early aseptic loosening. Silicoating, however, presupposes a clean and chemically active surface which can be achieved by atmospheric plasma or thermal surface treatment. In order to evaluate the effectiveness of silicoating the bond strengths of atmospheric plasma versus thermal surface treated and silicate layered ZPTA surfaces were compared with "as-fired" surfaces by utilising TiAlV probes (diameter 6 mm) for traction-adhesive strength tests. After preparing samples for traction-adhesive strength tests (sequence: ceramic substrate, silicate and silane, protective lacquer [PolyMA], bone cement, TiAlV probe) they were aged for up to 150 days at 37 °C in Ringer's solution. The bond strengths observed for all ageing intervals were well above 20 MPa and much higher and more hydrolytically stable for silicate layered compared with "as-fired" ZPTA samples. Silicoating may be effective for achieving high initial bond strength of bone cement on surfaces of oxide ceramics and also suitable to stabilise bond strength under hydrolytic conditions as present in the human body in the long-term. Activation by atmospheric plasma or thermal surface treatment seems to be effective for activation prior to silicoating. Due the proposed silicate layer migration, micromotions and debonding should be widely reduced or even eliminated. Georg Thieme Verlag KG Stuttgart · New York.

  15. Arthrodesis for failed knee arthroplasty. A report of 20 cases.

    PubMed

    Knutson, K; Lindstrand, A; Lidgren, L

    1985-01-01

    Twenty consecutive patients treated by arthrodesis for failed knee arthroplasty are reviewed. Eight hinged, five stabilised and seven compartmental prostheses were removed, for infection (15 cases), loosening (4) and instability (1). One patient refused a second-stage operation but the remainder gained sound fusion. Infected knees had a two-stage procedure with temporary insertion of gentamicin-loaded beads after removal of the prosthesis; all infections healed. Six arthrodeses using a Hoffmann-Vidal external fixator resulted in two temporary failures. One Ace-Fischer external fixation was successful. Of 10 primary attempts at arthrodesis with an intramedullary Küntscher nail, nine were successful; the tenth fused after two more attempts by the same method. The two failures of external fixation and two failures after Charnley single-frame compression done elsewhere were successfully fused with intramedullary nails. Delayed union in three cases fused after prolonged fixation and repeated bone grafts. The indications for and methods of arthrodesis after failed knee arthroplasty are discussed.

  16. [Amputation and equipment of the lower limb during the Revolution and the Empire].

    PubMed

    Vesselle, Benoît

    2014-01-01

    During the French Revolution and Napoleon's campaigns, above-knee or below-knee amputations were performed either immediately or with a delay, which favoured septic problems. A rapidly operated amputation by a well-trained surgeon was the best way to save the life of a soldier who suffered from an open comminuted fracture of a limb. The conditions on military campaigns were indeed hard ones: doctors and surgeons had practically no resources and the transportation of severely injured persons was difficult. Such conditions favoured the pain and the danger caused by an injury, and it was rather impossible for the medical corps to lavish repeated treatments on the wounds. The amputated soldiers were then given prostheses: either a traditional peg-leg, with a flexed knee joint for trans-tibial amputations, or an "imitative" prosthesis, which tended to look like a real leg with eventually an articulated knee or foot. The author mentions famous or unrecognized amputated men, describing significant events.

  17. Utilization rates of knee-arthroplasty in OECD countries.

    PubMed

    Pabinger, C; Lothaller, H; Geissler, A

    2015-10-01

    The number of knee arthroplasties and the prevalence of obesity are increasing exponentially. To date there have been no published reviews on utilization rates of knee arthroplasty in OECD countries. We analysed economic, medical and population data relating to knee arthroplasty surgeries performed in OECD countries. Gross domestic product (GDP), health expenditures, obesity prevalence, knee arthroplasty utilization rates and growth in knee arthroplasty rates per 100,000 population were assessed for total population, for patients aged 65 years and over, and patients aged 64 years and younger. Obesity prevalence and utilization of knee arthroplasty have increased significantly in the past. The mean utilization rate of knee arthroplasty was 150 (22-235) cases per 100,000 total population in 2011. The strongest annual increase (7%) occurred in patients 64 years and under. Differences between individual countries can be explained by economic and medical patterns, with countries with higher medical expenditures and obesity prevalence having significantly higher utilization rates. Countries with lower utilization rates have significantly higher growth in utilization rates. The future demand for knee prostheses will increase x-fold by 2030, with exact rates dependant upon economic, social and medical factors. We observed a 10-fold variation in the utilization of knee arthroplasty among OECD countries. A significant and strong correlation of GDP, health expenditures and obesity prevalence with utilization of knee arthroplasty was found. Patients aged 64 years and younger show a two-fold higher growth rate in knee arthroplasty compared to the older population. This trend could result in a four-fold demand for knee arthroplasty in OECD countries by 2030. Copyright © 2015 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  18. Sensory Feedback for Lower Extremity Prostheses Incorporating Targeted Muscle Reinnervation (TMR)

    DTIC Science & Technology

    2016-10-01

    amputation to establish baselines and guide development. The second technique makes use of Virtual Reality ( VR ) to provide visual and tactile...of view in VR (left) and real world (right) Figure 6: Confidence for offsets presented to Site 1 (closest to the knee) on the right in blue, and...presentations Three presentations were given at the Northwest Biomechanics Symposium 2016 Technologies or techniques We have pioneered a VR

  19. Amputation rehabilitation and prosthetic restoration. From surgery to community reintegration.

    PubMed

    Esquenazi, Alberto

    The purpose of this review is to summarize the literature related to the advances that have taken place in the management and rehabilitation care of limb amputation. Prostheses for the lower and upper limb amputee have changed greatly over the past several years, with advances in components, socket fabrication and fitting techniques, suspension systems and sources of power and electronic controls. Higher levels of limb amputation can now be fitted with functional prostheses, which allow more patients to achieve independent life styles. This is of particular importance for the multi-limb amputee. The rehabilitation of more traditional lower limb levels of amputation have also greatly benefited from the technological advances including energy storing feet, electronic control hydraulic knees, ankle rotators and shock absorbers to mention a few. For the upper limb amputee, myoelectric and proportional controlled terminal devices and elbow joints are now used routinely in some rehabilitation facilities. Experimental prosthetic fitting techniques and devices such as the use of osseo-implantation for suspension of the prosthesis, tension control hands or electromagnetic fluids for knee movement control will also be briefly discussed in this paper. It is possible to conclude from this review that many advances have occurred that have greatly impacted the functional outcomes of patients with limb amputation.

  20. Limited rotation of the mobile-bearing in a rotating platform total knee prosthesis.

    PubMed

    Garling, E H; Kaptein, B L; Nelissen, R G H H; Valstar, E R

    2007-01-01

    The hypothesis of this study was that the polyethylene bearing in a rotating platform total knee prosthesis shows axial rotation during a step-up motion, thereby facilitating the theoretical advantages of mobile-bearing knee prostheses. We examined 10 patients with rheumatoid arthritis who had a rotating platform total knee arthroplasty (NexGen LPS mobile, Zimmer Inc. Warsaw, USA). Fluoroscopic data was collected during a step-up motion six months postoperatively. A 3D-2D model fitting technique was used to reconstruct the in vivo 3D kinematics. The femoral component showed more axial rotation than the polyethylene mobile-bearing insert compared to the tibia during extension. In eight knees, the femoral component rotated internally with respect to the tibia during extension. In the other two knees the femoral component rotated externally with respect to the tibia. In all 10 patients, the femur showed more axial rotation than the mobile-bearing insert indicating the femoral component was sliding on the polyethylene of the rotating platform during the step-up motion. Possible explanations are a too limited conformity between femoral component and insert, the anterior located pivot location of the investigated rotating platform design, polyethylene on metal impingement and fibrous tissue formation between the mobile-bearing insert and the tibial plateau.

  1. [Endo-exo prostheses : Osseointegrated percutaneously channeled implants for rehabilitation after limb amputation].

    PubMed

    Aschoff, H-H; Juhnke, D-L

    2016-05-01

    In 1999 the first endo-exo femoral prosthesis (EEFP) was implanted in Germany in a patient who had suffered a traumatic above-knee amputation. This procedure involves a skeletally anchored exoprosthetic device that is inserted into the residual femur. The distal part of the implant protrudes transcutaneously and allows attachment to a prosthetic limb which provides direct force transmission to the external prosthetic components. The technique originated from dental implantology and helps to avoid possible problems resulting from treatment of amputated limbs using socket prostheses. In the meantime, durability times of over 10 years have now helped to invalidate the initially well-founded reservations held against the procedure. What advantages can be achieved by osseointegrated and percutaneously channeled prostheses and which problems had to be overcome for treatment. Critical evaluation of data from patients operated on in Lübeck, Germany from January 2003 to December 2014. With osseointegrated and percutaneously channeled prostheses permanent durability times can be achieved. Infection-associated soft tissue problems at the site of skin protrusion (stoma) can be successfully prevented. The creation of this so-called stoma means acceptance of a possible bacterial portal of entry into the body. Patient satisfaction has so far been high, postoperative rehabilitation is simplified and the technique could possibly lower the costs of medical treatment. Endo-exo prostheses have proved to be successful for more than 15 years. A critical appraisal of the indications as well as a close cooperation between the surgeon, orthopedic technician and the associated rehabilitation facilities with the patient are the basis for the long-term success of this relatively new treatment approach.

  2. Differences in knee flexion between the Genium and C-Leg microprocessor knees while walking on level ground and ramps.

    PubMed

    Lura, Derek J; Wernke, Matthew M; Carey, Stephanie L; Kahle, Jason T; Miro, Rebecca M; Highsmith, M Jason

    2015-02-01

    Microprocessor knees have improved the gait and functional abilities of persons with transfemoral amputation. The Genium prosthetic knee offers an advanced sensor and control system designed to decrease impairment by: allowing greater stance phase flexion, easing transitions between gait phases, and compensating for changes in terrain. The aim of this study was to determine differences between the knee flexion angle of persons using the Genium knee, the C-Leg knee, and non-amputee controls; and to evaluate the impact the prostheses on gait and level of impairment of the user. This study used a randomized experimental crossover of persons with transfemoral amputation using the Genium and C-Leg microprocessor knees (n=25), with an observational sample of non-amputee controls (n=5). Gait analysis by 3D motion tracking of subjects ambulating at different speeds on level ground and on 5° and 10° ramps was completed. Use of the Genium resulted in a significant increase in peak knee flexion for swing (5°, p<0.01, d=0.34) and stance (2°, p<0.01, d=0.19) phases relative to C-Leg use. There was a high degree of variability between subjects, and significant differences still remain between the Genium group and the control group's knee flexion angles for most speeds and slopes. The Genium knee generally increases flexion in swing and stance, potentially decreasing the level of impairment for persons with transfemoral amputation. This study demonstrates functional differences between the C-Leg and Genium knees to help prosthetists determine if the Genium will provide functional benefits to individual patients. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Estimation of Quasi-Stiffness of the Human Knee in the Stance Phase of Walking

    PubMed Central

    Shamaei, Kamran; Sawicki, Gregory S.; Dollar, Aaron M.

    2013-01-01

    Biomechanical data characterizing the quasi-stiffness of lower-limb joints during human locomotion is limited. Understanding joint stiffness is critical for evaluating gait function and designing devices such as prostheses and orthoses intended to emulate biological properties of human legs. The knee joint moment-angle relationship is approximately linear in the flexion and extension stages of stance, exhibiting nearly constant stiffnesses, known as the quasi-stiffnesses of each stage. Using a generalized inverse dynamics analysis approach, we identify the key independent variables needed to predict knee quasi-stiffness during walking, including gait speed, knee excursion, and subject height and weight. Then, based on the identified key variables, we used experimental walking data for 136 conditions (speeds of 0.75–2.63 m/s) across 14 subjects to obtain best fit linear regressions for a set of general models, which were further simplified for the optimal gait speed. We found R2 > 86% for the most general models of knee quasi-stiffnesses for the flexion and extension stages of stance. With only subject height and weight, we could predict knee quasi-stiffness for preferred walking speed with average error of 9% with only one outlier. These results provide a useful framework and foundation for selecting subject-specific stiffness for prosthetic and exoskeletal devices designed to emulate biological knee function during walking. PMID:23533662

  4. Long-term stress distribution patterns of the ankle joint in varus knee alignment assessed by computed tomography osteoabsorptiometry.

    PubMed

    Onodera, Tomohiro; Majima, Tokifumi; Iwasaki, Norimasa; Kamishima, Tamotsu; Kasahara, Yasuhiko; Minami, Akio

    2012-09-01

    The stress distribution of an ankle under various physiological conditions is important for long-term survival of total ankle arthroplasty. The aim of this study was to measure subchondral bone density across the distal tibial joint surface in patients with malalignment/instability of the lower limb. We evaluated subchondral bone density across the distal tibial joint in patients with malalignment/instability of the knee by computed tomography (CT) osteoabsorptiometry from ten ankles as controls and from 27 ankles with varus deformity/instability of the knee. The quantitative analysis focused on the location of the high-density area at the articular surface, to determine the resultant long-term stress on the ankle joint. The area of maximum density of subchondral bone was located in the medial part in all subjects. The pattern of maximum density in the anterolateral area showed stepwise increases with the development of varus deformity/instability of the knee. Our results should prove helpful for designing new prostheses and determining clinical indications for total ankle arthroplasty.

  5. Clinical results of Hi-tech Knee II total knee arthroplasty in patients with rheumatoid athritis: 5- to 12-year follow-up.

    PubMed

    Yamanaka, Hajime; Goto, Ken-ichiro; Suzuki, Munetaka

    2012-02-22

    Total knee arthroplasty (TKA) is a common form of treatment to relieve pain and improve function in cases of rheumatoid arthritis (RA). Good clinical outcomes have been reported with a variety of TKA prostheses. The cementless Hi-Tech Knee II cruciate-retaining (CR)-type prosthesis, which has 6 fins at the anterior of the femoral component, posterior cruciate ligament (PCL) retention, flat-on-flat surface component geometry, all-polyethylene patella, strong initial fixation by the center screw of the tibial base plate, 10 layers of titanium alloy fiber mesh, and direct compression molded ultra high molecular weight polyethylene (UHMWPE), is appropriate for TKA in the Japanese knee.The present study was performed to evaluate the clinical results of primary TKA in RA using the cementless Hi-Tech Knee II CR-type prosthesis. We performed 32 consecutive primary TKAs using cementless Hi-Tech Knee II CR-type prosthesis in 31 RA patients. The average follow-up period was 8 years 3 months. Clinical evaluations were performed according to the American Knee Society (KS) system, knee score, function score, radiographic evaluation, and complications. The mean postoperative maximum flexion angle was 115.6°, and the KS knee score and function score improved to 88 and 70 after surgery, respectively. Complications, such as infection, occurred in 1 patient and revision surgery was performed. There were no cases of loosening in this cohort, and prosthesis survival rate was 96.9% at 12 years postoperatively. These results suggest that TKA using the cementless Hi-Tech Knee II CR-type prosthesis is a very effective form of treatment in RA patients at 5 to 12 years postoperatively. Further long-term follow-up studies are required to determine the ultimate utility of this type of prosthesis.

  6. Gait Parameters and Functional Outcomes After Total Knee Arthroplasty Using Persona Knee System With Cruciate Retaining and Ultracongruent Knee Inserts.

    PubMed

    Rajgopal, Ashok; Aggarwal, Kalpana; Khurana, Anshika; Rao, Arun; Vasdev, Attique; Pandit, Hemant

    2017-01-01

    Total knee arthroplasty is a well-established treatment for managing end-stage symptomatic knee osteoarthritis. Currently, different designs of prostheses are available with majority ensuring similar clinical outcomes. Altered surface geometry is introduced to strive toward gaining superior outcomes. We aimed to investigate any differences in functional outcomes between 2 different polyethylene designs namely the Persona CR (cruciate retaining) and Persona UC (ultracongruent) tibial inserts (Zimmer-Biomet, Warsaw, IN). This prospective single blind, single-surgeon randomized controlled trial reports on 105 patients, (66 female and 39 male), who underwent simultaneous bilateral total knee arthroplasty using the Persona knee system (Zimmer-Biomet) UC inserts in one side and CR inserts in the contralateral side. By a blind assessor, at regular time intervals patients were assessed in terms of function and gait. The functional knee scoring scales used were the Western Ontario and McMaster Universities Osteoarthritis Index and Modified Knee Society Score. The gait parameters evaluated were foot pressure and step length. During the study period, no patient was lost to follow-up or underwent revision surgery for any cause. Western Ontario and McMaster Universities Osteoarthritis Index scores, Modified Knee Society Score, and knee range of motion of all 105 patients assessed preoperatively and postoperatively at 6 months, 1 year, and 2 years showed statistically better results (P < .05) for UC inserts. Gait analysis measuring foot pressures and step length, however, did not show any statistically significant differences at 2-year follow-up. Ultracongruent tibial inserts show significantly better functional outcomes as compared to CR inserts during a 2-year follow-up period. However, in this study these findings were not shown to be attributed to differences in gait parameters. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. [Conservative and operative treatment of working age patients with gonarthritis. Economic considerations].

    PubMed

    Malzahn, J

    2014-06-01

    The development of the overall achievements for hospital performance since the introduction in Germany of the diagnosis-related groups (DRG) system in 2003 is the subject of healthcare political discussion. The field of prosthetics is often at the center of considerations. After consideration of the development of achievements with international and regional earnings, the question was investigated how the average expenditure for patients with gonarthritis developed in a time period of 1 year before and after implantation of total knee prostheses. The study was based on individual patient data from the accounting data of the AOK (General Regional Healthcare Insurance) from the categories, inpatient care, panel physician treatment, pharmaceuticals and medicines as well as disability leave periods. The data include the average expenditure and disability times calculated by the AOK for individual patients 12 months before and 12 months after implantation of a total knee prosthesis. The methods were selected because the international classification of diseases (ICD) coding does not allow a differentiation in the degree of severity and, therefore, a comparison of patients who were only conservatively treated within the scope of panel physicians which would have led to problems in risk adjustment. Due to a lack of coding guidelines for treatment by panel physicians, the accuracy of the diagnosis is also limited in comparison to inpatient treatment data. The expenditure and the average disability leave for gonarthritis patients were higher in the year following implantation of total knee prostheses than in the year prior to implantation. No conclusions can be drawn from the provision of service data with respect to the quality of life of the patients. Investigations over a longer time period seem to be necessary.

  8. Are critical pathways and implant standardization programs effective in reducing costs in total knee replacement operations?

    PubMed

    Ho, David M; Huo, Michael H

    2007-07-01

    Total knee replacement (TKR) operation is one of the most effective procedures, both clinically and in terms of cost. Because of increased volume and cost for this procedure during the past 3 decades, TKRs are often targeted for cost reduction. The purpose of this study was to evaluate the efficacy of two cost reducing methodologies, establishment of critical clinical pathways, and standardization of implant costs. Ninety patients (90 knees) were randomly selected from a population undergoing primary TKR during a 2-year period at a tertiary teaching hospital. Patients were assigned to three groups that corresponded to different strategies implemented during the evolution of the joint-replacement program. Medical records were reviewed for type of anesthesia, operative time, length of stay, and any perioperative complications. Financial information for each patient was compared among the three groups. Data analysis demonstrated that the institution of a critical pathway significantly shortened length of hospital stay and was effective in reducing the hospital costs by 18% (p < 0.05). In addition, standardization of surgical techniques under the care of a single surgeon substantially reduced the operative time. Selection of implants from a single vendor did not have any substantial effect in additionally reducing the costs. Standardized postoperative management protocols and critical clinical pathways can reduce costs and operative time. Future efforts must focus on lowering the costs of the prostheses, particularly with competitive bidding or capitation of prostheses costs. Although a single-vendor approach was not effective in this study, it is possible that a cost reduction could have been realized if more TKRs were performed, because the pricing contract was based on projected volume of TKRs to be done by the hospital.

  9. The Oxford unicompartmental knee fails at a high rate in a high-volume knee practice.

    PubMed

    Schroer, William C; Barnes, C Lowry; Diesfeld, Paul; LeMarr, Angela; Ingrassia, Rachel; Morton, Diane J; Reedy, Mary

    2013-11-01

    The Oxford knee is a unicompartmental implant featuring a mobile-bearing polyethylene component with excellent long-term survivorship results reported by the implant developers and early adopters. By contrast, other studies have reported higher revision rates in large academic practices and in national registries. Registry data have shown increased failure with this implant especially by lower-volume surgeons and institutions. In the setting of a high-volume knee arthroplasty practice, we sought to determine (1) the failure rate of the Oxford unicompartmental knee implant using a failure definition for aseptic loosening that combined clinical features, plain radiographs, and scintigraphy, and (2) whether increased experience with this implant would decrease failure rate, if there is a learning curve effect. Eighty-three Oxford knee prostheses were implanted between September 2005 and July 2008 by the principal investigator. Radiographic and clinical data were available for review for all cases. A failed knee was defined as having recurrent pain after an earlier period of recovery from surgery, progressive radiolucent lines compared with initial postoperative radiographs, and a bone scan showing an isolated area of uptake limited to the area of the replaced compartment. Eleven knees in this series failed (13%); Kaplan-Meier survivorship was 86.5% (95% CI, 78.0%-95.0%) at 5 years. Failure occurrences were distributed evenly over the course of the study period. No learning curve effect was identified. Based on these findings, including a high failure rate of the Oxford knee implant and the absence of any discernible learning curve effect, the principal investigator no longer uses this implant.

  10. Expectations of younger patients concerning activities after knee arthroplasty: are we asking the right questions?

    PubMed

    Witjes, Suzanne; van Geenen, Rutger C I; Koenraadt, Koen L M; van der Hart, Cor P; Blankevoort, Leendert; Kerkhoffs, Gino M M J; Kuijer, P Paul F M

    2017-02-01

    Indications for total and unicondylar knee arthroplasty (KA) have expanded to younger patients, in which Patient-Reported Outcome Measures (PROMs) often show ceiling effects. This might be due to higher expectations. Our aims were to explore expectations of younger patients concerning activities in daily life, work and leisure time after KA and to assess to what extent PROMs meet and evaluate these activities of importance. Focus groups were performed among osteoarthritis (OA) patients <65 years awaiting KA, in which they indicated what activities they expected to perform better in daily life, work and leisure time after KA. Additionally, 28 activities of daily life, 17 of work and 27 of leisure time were depicted from seven PROMS, which were rated on importance, frequency and bother. A total score, representing motivation for surgery, was also calculated. Data saturation was reached after six focus groups including 37 patients. Younger OA patients expect to perform better on 16 activities after KA, including high-impact leisure time activities. From the PROMs, daily life and work activities were rated high in both importance and motivation for surgery, but for leisure time activities importance varied highly between patients. All seven PROMs score activities of importance, but no single PROM incorporates all activities rated important. Younger patients expect to perform better on many activities of daily life, work and leisure time after KA, and often at demanding levels. To measure outcomes of younger patients, we suggest using PROMs that include work and leisure time activities besides daily life activities, in which preferably scored activities can be individualized.

  11. Is repetitive intraoperative splash basin use a source of bacterial contamination in total joint replacement?

    PubMed

    Glait, Sergio A; Schwarzkopf, Ran; Gould, Steven; Bosco, Joseph; Slover, James

    2011-09-09

    Splash basins are used in arthroplasty cases to wash instruments. Several studies in the literature have shown these basins being a potential source of bacterial infection. This study assesses the risk of contamination of intraoperative splash basins used to wash and store instruments. A total of 46 random clean primary arthroplasty cases (32 hips, 13 knees, and 1 unicondylar knee) were studied by taking cultures of sterile splash basins as soon as they are opened (controls) and again at wound closure after instruments and debris have come into contact with the sterile water. All cultures were taken with sterile culture swabs and sent to the laboratory for aerobic, anaerobic, and fungal culture. Outcome measured was any positive culture. A total of 92 cultures from 46 cases were tested. Only 1 (2.17%) control culture, which grew Streptococcus viridans, was positive for bacterial growth. One of 46 samples (2.17%) taken at wound closure was positive for coagulase-negative Staphylococcus. Mean time between basin opening and wound closure was 180±45 minutes. For the 1 infected sample taken at the conclusion of the case, it was 240 minutes. Previous studies show contamination rates as high as 74% for splash basins used intraoperatively. Our study contradicts the belief that splash basins are a high source of infection, with only 2.17% of basins showing contamination. Splash basins can be a potential source of contamination, but the risk is not as high as previously cited in the orthopedic literature. Copyright 2011, SLACK Incorporated.

  12. Pre-operative Asymptomatic Bacteriuria: A Risk Factor For Prosthetic Joint Infection?

    PubMed

    Weale, R; El-Bakri, F; Saeed, Kordo

    2018-04-13

    Infection is a rare complication following implantation of prosthetic material into a joint. The impact of asymptomatic bacteriuria (ASB) before elective operations and the subsequent risk of prosthetic joint infection (PJI) are not well understood. • Assess the prevalence of ASB amongst patients undergoing total arthroplasty of the hip and knee. • Determine the rates of PJI diagnosed within two years of the arthroplasty and if ASB is an independent risk factor for developing PJI. Patients who had total/unicondylar knee or total hip arthroplasty were retrospectively reviewed over a five-year period. Pre-operative urine samples within one year of surgery were analysed and those with ASB identified. Primary outcome was prosthetic joint infection (PJI) within the first postoperative year. 5542 patients were included. 4368 had a pre-operative urine culture recorded. The prevalence of ASB was 140 of 4368 (3.2%). The overall PJI rate was 56 of 5542 (1.01%). Of those with a PJI, 33 had a pre-operative urine sample recorded. The infection rate in the ASB group was 5% (7 of 140), in the no-ASB group it was 0.61% (26 of 4228) and in the group without a urine sample it was 1.96% (23 of 1174) (p value <0.001). The ASB isolate was the same microorganism as the PJI isolate in only one of the seven cases. The association between ASB and PJI is statistically significant, but the urine isolates did not relate to the isolates in the prosthetic joint, suggestive the relationship is unlikely causal. Copyright © 2018. Published by Elsevier Ltd.

  13. Development of an above-knee prosthesis equipped with a microcomputer-controlled knee joint: first test results.

    PubMed

    Aeyels, B; Peeraer, L; Vander Sloten, J; Van der Perre, G

    1992-05-01

    The shortcomings of conventional above-knee prostheses are due to their lack of adaptive control. Implementation of a microcomputer controlling the knee joint in a passive way has been suggested to enhance the patient's gait comfort, safety and cosmesis. This approach was used in the design of a new prosthetic system for the above-knee amputee, and tested on one patient. The knee joint of a conventional, modular prosthesis was replaced by a knee joint mechanism, equipped with a controllable brake on the knee joint axis. Sensors and a microcomputer were added, keeping the system self-contained. The modularity of the design permits the use of an alternative, external, PC-based control unit, emulating the self-contained one, and offering extended data monitoring and storage facilities. For both units an operating environment was written, including sensor/actuator interfacing and the implementation of a real-time interrupt, executing the control algorithm. A double finite state approach was used in the design of the control algorithm. On a higher level, the mode identification algorithm reveals the patient's intent. Within a specific mode (lower level), the relevant mode control algorithm looks for the current phase within the gait cycle. Within a particular phase, a specific simple control action with the brake replaces normal knee muscle activity. Tests were carried out with one prosthetic patient using a basic control algorithm for level walking, allowing controlled knee flexion during stance phase. The technical feasibility of such a concept is illustrated by the test results, even though only flexion during early stance phase was controlled during the trials.(ABSTRACT TRUNCATED AT 250 WORDS)

  14. Revision of Infected Total Knee Arthroplasty: Two-Stage Reimplantation Using an Antibiotic-Impregnated Static Spacer

    PubMed Central

    Almeida, Fernando; Renovell, Pablo; Morante, Elena; López, Raúl

    2013-01-01

    Background A two-stage revision remains as the "gold standard" treatment for chronically infected total knee arthroplasties. Methods Forty-five septic knee prostheses were revised with a minimum follow-up of 5 years. Static antibiotic-impregnated cement spacers were used in all cases. Intravenous antibiotics according to sensitivity test of the culture were applied during patients' hospital stay. Oral antibiotics were given for another 5 weeks. Second-stage surgery was undertaken after control of infection with normal erythrocyte sedimentation rate and C-reactive protein values. Extensile techniques were used if needed and metallic augments were employed for bone loss in 32 femoral and 29 tibial revisions. Results The average interval between the first-stage resection and reimplantation was 4.4 months. Significant improvement was obtained with respect to visual analog scale pain and clinical and functional scores, and infection was eradicated in 95.6% of cases following a two-stage revision total knee arthroplasty. Radiographic evaluation showed suitable alignment without signs of mechanical loosening. Conclusions This technique is a reasonable procedure to eradicate chronic infection in knee arthroplasty and provides proper functional and clinical results. However, it sometimes requires extensile surgical approaches that could imply arduous surgeries. Metallic augments with cementless stems available in most of the knee revision systems are a suitable alternative to handle bone deficiencies, avoiding the use of bone allografts with its complications. PMID:24009903

  15. Staphylococcus aureus infections following knee and hip prosthesis insertion procedures.

    PubMed

    Arduino, Jean Marie; Kaye, Keith S; Reed, Shelby D; Peter, Senaka A; Sexton, Daniel J; Chen, Luke F; Hardy, N Chantelle; Tong, Steven Yc; Smugar, Steven S; Fowler, Vance G; Anderson, Deverick J

    2015-01-01

    Staphylococcus aureus is the most common and most important pathogen following knee and hip arthroplasty procedures. Understanding the epidemiology of invasive S. aureus infections is important to quantify this serious complication. This nested retrospective cohort analysis included adult patients who had undergone insertion of knee or hip prostheses with clean or clean-contaminated wound class at 11 hospitals between 2003-2006. Invasive S. aureus infections, non-superficial incisional surgical site infections (SSIs) and blood stream infections (BSIs), were prospectively identified following each procedure. Prevalence rates, per 100 procedures, were estimated. 13,719 prosthetic knee (62%) and hip (38%) insertion procedures were performed. Of 92 invasive S. aureus infections identified, SSIs were more common (80%) than SSI and BSI (10%) or BSI alone (10%). The rate of invasive S. aureus infection/100 procedures was 0.57 [95% CI: 0.43-0.73] for knee insertion and 0.83 [95% CI: 0.61-1.08] for hip insertion. More than half (53%) were methicillin-resistant. Median time-to-onset of infection was 34 and 26 days for knee and hip insertion, respectively. Infection was associated with higher National Healthcare Safety Network risk index (p ≤ 0.0001). Post-operative invasive S. aureus infections were rare, but difficult-to-treat methicillin-resistant infections were relatively common. Optimizing preventative efforts may greatly reduce the healthcare burden associated with S. aureus infections.

  16. Revision of infected total knee arthroplasty: two-stage reimplantation using an antibiotic-impregnated static spacer.

    PubMed

    Silvestre, Antonio; Almeida, Fernando; Renovell, Pablo; Morante, Elena; López, Raúl

    2013-09-01

    A two-stage revision remains as the "gold standard" treatment for chronically infected total knee arthroplasties. Forty-five septic knee prostheses were revised with a minimum follow-up of 5 years. Static antibiotic-impregnated cement spacers were used in all cases. Intravenous antibiotics according to sensitivity test of the culture were applied during patients' hospital stay. Oral antibiotics were given for another 5 weeks. Second-stage surgery was undertaken after control of infection with normal erythrocyte sedimentation rate and C-reactive protein values. Extensile techniques were used if needed and metallic augments were employed for bone loss in 32 femoral and 29 tibial revisions. The average interval between the first-stage resection and reimplantation was 4.4 months. Significant improvement was obtained with respect to visual analog scale pain and clinical and functional scores, and infection was eradicated in 95.6% of cases following a two-stage revision total knee arthroplasty. Radiographic evaluation showed suitable alignment without signs of mechanical loosening. This technique is a reasonable procedure to eradicate chronic infection in knee arthroplasty and provides proper functional and clinical results. However, it sometimes requires extensile surgical approaches that could imply arduous surgeries. Metallic augments with cementless stems available in most of the knee revision systems are a suitable alternative to handle bone deficiencies, avoiding the use of bone allografts with its complications.

  17. Total knee replacement with natural rollback.

    PubMed

    Wachowski, Martin Michael; Walde, Tim Alexander; Balcarek, Peter; Schüttrumpf, Jan Philipp; Frosch, Stephan; Stauffenberg, Caspar; Frosch, Karl-Heinz; Fiedler, Christoph; Fanghänel, Jochen; Kubein-Meesenburg, Dietmar; Nägerl, Hans

    2012-03-20

    A novel class of total knee replacement (AEQUOS G1) is introduced which features a unique design of the articular surfaces. Based on the anatomy of the human knee and differing from all other prostheses, the lateral tibial "plateau" is convexly curved and the lateral femoral condyle is posteriorly shifted in relation to the medial femoral condyle. Under compressive forces the configuration of the articular surfaces of human knees constrains the relative motion of femur and tibia in flexion/extension. This constrained motion is equivalent to that of a four-bar linkage, the virtual 4 pivots of which are given by the centres of curvature of the articulating surfaces. The dimensions of the four-bar linkage were optimized to the effect that constrained motion of the total knee replacement (TKR) follows the flexional motion of the human knee in close approximation, particularly during gait. In pilot studies lateral X-ray pictures have demonstrated that AEQUOS G1 can feature the natural rollback in vivo. Rollback relieves the load of the patello-femoral joint and minimizes retropatellar pressure. This mechanism should reduce the prevalence of anterior knee pain. The articulating surfaces roll predominantly in the stance phase. Consequently sliding friction is replaced by the lesser rolling friction under load. Producing rollback should minimize material wear due to friction and maximize the lifetime of the prosthesis. To definitely confirm these theses one has to wait for the long term results. Copyright © 2011 Elsevier GmbH. All rights reserved.

  18. Impact of a stance phase microprocessor-controlled knee prosthesis on level walking in lower functioning individuals with a transfemoral amputation.

    PubMed

    Eberly, Valerie J; Mulroy, Sara J; Gronley, JoAnne K; Perry, Jacquelin; Yule, William J; Burnfield, Judith M

    2014-12-01

    For individuals with transfemoral amputation, walking with a prosthesis presents challenges to stability and increases the demand on the hip of the prosthetic limb. Increasing age or comorbidities magnify these challenges. Computerized prosthetic knee joints improve stability and efficiency of gait, but are seldom prescribed for less physically capable walkers who may benefit from them. To compare level walking function while wearing a microprocessor-controlled knee (C-Leg Compact) prosthesis to a traditionally prescribed non-microprocessor-controlled knee prosthesis for Medicare Functional Classification Level K-2 walkers. Crossover. Stride characteristics, kinematics, kinetics, and electromyographic activity were recorded in 10 participants while walking with non-microprocessor-controlled knee and Compact prostheses. Walking with the Compact produced significant increase in velocity, cadence, stride length, single-limb support, and heel-rise timing compared to walking with the non-microprocessor-controlled knee prosthesis. Hip and thigh extension during late stance improved bilaterally. Ankle dorsiflexion, knee extension, and hip flexion moments of the prosthetic limb were significantly improved. Improvements in walking function and stability on the prosthetic limb were demonstrated by the K-2 level walkers when using the C-Leg Compact prosthesis. Understanding the impact of new prosthetic designs on gait mechanics is essential to improve prescription guidelines for deconditioned or older persons with transfemoral amputation. Prosthetic designs that improve stability for safety and walking function have the potential to improve community participation and quality of life. © The International Society for Prosthetics and Orthotics 2013.

  19. Problems with Excessive Residual Lower Leg Length in Pediatric Amputees

    PubMed Central

    Osebold, William R; Lester, Edward L; Christenson, Donald M

    2001-01-01

    We studied six pediatric amputees with long below-knee residual limbs, in order to delineate their functional and prosthetic situations, specifically in relation to problems with fitting for dynamic-response prosthetic feet. Three patients had congenital pseudoarthrosis of the tibia secondary to neurofibromatosis, one had fibular hemimelia, one had a traumatic amputation, and one had amputation secondary to burns. Five patients had Syme's amputations, one had a Boyd amputation. Ages at amputation ranged from nine months to five years (average age 3 years 1 month). After amputation, the long residual below-knee limbs allowed fitting with only the lowest-profile prostheses, such as deflection plates. In three patients, the femoral dome to tibial plafond length was greater on the amputated side than on the normal side. To allow room for more dynamic-response (and larger) foot prostheses, two patients have undergone proximal and distal tibial-fibular epiphyseodeses (one at age 5 years 10 months, the other at 3 years 7 months) and one had a proximal tibial-fibular epiphyseodesis at age 7 years 10 months. (All three patients are still skeletally immature.) The families of two other patients are considering epiphyseodeses, and one patient is not a candidate (skeletally mature). Scanogram data indicate that at skeletal maturity the epiphyseodesed patients will have adequate length distal to their residual limbs to fit larger and more dynamic-response prosthetic feet. PMID:11813953

  20. Minimally invasive fixation of type B and C interprosthetic femoral fractures.

    PubMed

    Ehlinger, M; Czekaj, J; Adam, P; Brinkert, D; Ducrot, G; Bonnomet, F

    2013-09-01

    Interprosthetic femoral fractures are rare and raise unresolved treatment issues such as the length of the fixation material that best prevents secondary fractures. Awareness of the advantages of locked-plate fixation via a minimally invasive approach remains limited, despite the potential of this method for improving success rates. Femur-spanning (from the trochanters to the condyles) locked-plate fixation via a minimally invasive approach provides high healing rates with no secondary fractures. From January 2004 to May 2011, all eight patients seen for interprosthetic fractures were treated with minimally invasive locked-plate fixation. Mean time since hip arthroplasty was 47.5 months and mean time since knee arthroplasty was 72.6 months. There were 12 standard primary prostheses and four revision prostheses; 11 prostheses were cemented and a single prosthesis showed femoral loosening. Classification about the hip prostheses was Vancouver B in one patient and Vancouver C in seven patients; about the knee prosthesis, the fracture was SoFCOT B in three patients and SOFCOT C in five patients, and a single fracture was SoFCOT D. Minimally invasive locking-plate fixation was performed in all eight patients, with installation on a traction table in seven patients. Healing was obtained in all eight patients, after a mean of 14 weeks (range, 12-16 weeks). One patient had malalignment with more than 5° of varus. There were no general or infectious complications. One patient died, 32 months after surgery. The mean Parker-Palmer mobility score decreased from 6.2 pre-operatively to 2.5 at last follow-up. Early construct failure after 3 weeks in one patient required surgical revision. There was no change in implant fixation at last follow-up. No secondary fractures were recorded. In patients with type B or C interprosthetic fractures, femur-spanning fixation not only avoids complications related to altered bone stock and presence of prosthetic material, but also decreases the risk of secondary fractures by eliminating stress riser zones. The minimally invasive option enhances healing by preserving the fracture haematoma. Thus, healing was obtained consistently in our patients, with no secondary fractures, although the construct failed in one patient. Level IV. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  1. Improvement in the clinical practicability of roentgen stereophotogrammetric analysis (RSA): free from the use of the dual X-ray equipment.

    PubMed

    Shih, Kao-Shang; Lee, Chian-Her; Syu, Ci-Bin; Lai, Jiing-Yih; Chen, Kuo-Jen; Lin, Shang-Chih

    2012-10-01

    After total knee replacement, the monitoring of the prosthetic performance is often done by roentgenographic examination. However, the two-dimensional (2D) roentgen images only provide information about the projection onto the anteroposterior (AP) and mediolateral (ML) planes. Historically, the model-based roentgen stereophotogrammetric analysis (RSA) technique has been developed to predict the spatial relationship between prostheses by iteratively comparing the projective data for the prosthetic models and the roentgen images. During examination, the prosthetic poses should be stationary. This should be ensured, either by the use of dual synchronized X-ray equipment or by the use of a specific posture. In practice, these methods are uncommon or technically inconvenient during follow-up examination. This study aims to develop a rotation platform to improve the clinical applicability of the model-based RSA technique. The rotation platform allows the patient to assume a weight-bearing posture, while being steadily rotated so that both AP and ML knee images can be obtained. This study uses X-ray equipment with a single source and flat panel detectors (FPDs). Four tests are conducted to evaluate the quality of the FPD images, steadiness of the rotation platform, and accuracy of the RSA results. The results show that the distortion-induced error of the FPD image is quite minor, and the prosthetic size can be cautiously calibrated by means of the scale ball(s). The rotation platform should be placed closer to the FPD and orthogonal to the projection axis of the X-ray source. Image overlap of the prostheses can be avoided by adjusting both X-ray source and knee posture. The device-induced problems associated with the rotation platform include the steadiness of the platform operation and the balance of the rotated subject. Sawbone tests demonstrate that the outline error, due to the platform, is of the order of the image resolution (= 0.145 mm). In conclusion, the rotation platform with steady rotation, a knee support, and a handle can serve as an alternative method to take prosthetic images, without the loss in accuracy associated with the RSA method.

  2. Clinical results of Hi-tech Knee II total knee arthroplasty in patients with rheumatoid athritis: 5- to 12-year follow-up

    PubMed Central

    2012-01-01

    Background Total knee arthroplasty (TKA) is a common form of treatment to relieve pain and improve function in cases of rheumatoid arthritis (RA). Good clinical outcomes have been reported with a variety of TKA prostheses. The cementless Hi-Tech Knee II cruciate-retaining (CR)-type prosthesis, which has 6 fins at the anterior of the femoral component, posterior cruciate ligament (PCL) retention, flat-on-flat surface component geometry, all-polyethylene patella, strong initial fixation by the center screw of the tibial base plate, 10 layers of titanium alloy fiber mesh, and direct compression molded ultra high molecular weight polyethylene (UHMWPE), is appropriate for TKA in the Japanese knee. The present study was performed to evaluate the clinical results of primary TKA in RA using the cementless Hi-Tech Knee II CR-type prosthesis. Materials and methods We performed 32 consecutive primary TKAs using cementless Hi-Tech Knee II CR-type prosthesis in 31 RA patients. The average follow-up period was 8 years 3 months. Clinical evaluations were performed according to the American Knee Society (KS) system, knee score, function score, radiographic evaluation, and complications. Results The mean postoperative maximum flexion angle was 115.6°, and the KS knee score and function score improved to 88 and 70 after surgery, respectively. Complications, such as infection, occurred in 1 patient and revision surgery was performed. There were no cases of loosening in this cohort, and prosthesis survival rate was 96.9% at 12 years postoperatively. Conclusion These results suggest that TKA using the cementless Hi-Tech Knee II CR-type prosthesis is a very effective form of treatment in RA patients at 5 to 12 years postoperatively. Further long-term follow-up studies are required to determine the ultimate utility of this type of prosthesis. PMID:22356935

  3. Changes in the three-dimensional load-bearing axis after mobile-bearing total knee arthroplasty.

    PubMed

    Ishii, Yoshinori; Noguchi, Hideo; Sato, Junko; Ezawa, Nobukazu; Toyabe, Shin-Ichi

    2016-07-01

    The purpose of this study was to assess changes in the three-dimensional (3D) load-bearing mechanical axis (LBMA) preoperatively and at 3 weeks and more than 1-year follow-up after total knee arthroplasty (TKA), and effects of the degree of constraint in the anteroposterior (AP) direction because of the retention of the posterior cruciate ligament (PCL) and the implant design on the changes in LBMA. We evaluated 157 knees from 131 patients, including 79 knees that received meniscal-bearing-type (PCL-retaining) and 78 knees that received rotating-platform-type (PCL-substituting) prostheses. Quantitative 3D computed tomography was used to assess changes in the location of the pre- and postoperative LBMA at the tibial plateau level. Changes in the 3D axis were mainly found from medial to lateral and posterior to anterior in both implant designs with no significant differences. Change in the mediolateral (ML) direction was improved soon after TKA, but change in the AP direction improved more gradually over time. The different constraints in the AP direction because of the retention of the PCL and different implant designs did not affect the changes in the LBMA. The LBMA in the AP direction more than 1 year postoperatively, as well as the LBMA in the ML direction at 3 weeks, appears to shift toward the location found in normal knees after TKA, regardless of the type of prosthetic constraint. These changes may be an important factor that influences the periarticular knee bone mineral density which load bearing may be related to. Level II, Prognostic study.

  4. Knee Joint Loading during Gait in Healthy Controls and Individuals with Knee Osteoarthritis

    PubMed Central

    Kumar, Deepak; Manal, Kurt T.; Rudolph, Katherine S.

    2013-01-01

    Objective People with knee osteoarthritis (OA) are thought to walk with high loads at the knee which are yet to be quantfied using modeling techniques that account for subject specific EMG patterns, kinematics and kinetics. The objective was to estimate medial and lateral loading for people with knee OA and controls using an approach that is sensitive to subject specific muscle activation patterns. Methods 16 OA and 12 control (C) subjects walked while kinematic, kinetic and EMG data were collected. Muscle forces were calculated using an EMG-Driven model and loading was calculated by balancing the external moments with internal muscle and contact forces Results OA subjects walked slower and had greater laxity, static and dynamic varus alignment, less flexion and greater knee adduction moment (KAM). Loading (normalized to body weight) was no different between the groups but OA subjects had greater absolute medial load than controls and maintained a greater %total load on the medial compartment. These patterns were associated with body mass, sagittal and frontal plane moments, static alignment and close to signficance for dynamic alignment. Lateral compartment unloading during mid-late stance was observed in 50% of OA subjects. Conclusions Loading for control subjects was similar to data from instrumented prostheses. Knee OA subjects had high medial contact loads in early stance and half of the OA cohort demonstared lateral compartment lift-off. Results suggest that interventions aimed at reducing body weight and dynamic malalignment might be effective in reducing medial compartment loading and establishing normal medio-lateral load sharing patterns. PMID:23182814

  5. Unicompartmental knee prostheses: in vitro wear assessment of the menisci tibial insert after two different fixation methods

    NASA Astrophysics Data System (ADS)

    Affatato, S.; Spinelli, M.; Zavalloni, M.; Carmignato, S.; Lopomo, N.; Marcacci, M.; Viceconti, M.

    2008-10-01

    Knee osteoarthritis is a complex clinical scenario where many biological and mechanical factors influence the severity of articular degenerative changes. Minimally invasive knee prosthetic surgery, with only a compartment replacement (unicompartmental knee replacement), might be a good compromise between osteotomy and total knee prosthesis. The focus of this study was to develop and validate a protocol to assess the fixation method of the femoral components in mechanical simulation, for pre-clinical validation; the wear behaviour of two different fixation frames was quantified and compared. In particular, two different wear tests were conducted using the same knee simulator, the same load profiles and the same kinematics; two different fixation methods were applied to the femoral sleds (synthetic femur and metal block). Surface characterization on both articulating bearings was performed by a roughness measuring machine and coordinate measuring machine. The wear produced by the tibial inserts using the synthetic femur was considerably higher than the wear registered by the metal-block holder. Roughness measurements on femoral sleds showed a limited number of scratches with high Rt values for the metal-block set-up; the damaged surface broadened in the case of femoral condyles and tibial inserts mounted on composite bone, but lower Rt and linear penetration values were measured. The two holding frames showed different wear activities as a consequence of dissimilar dynamic performance. Further observations should be made in vivo to prove the actual importance of synthetic bone simulations and specific material behaviour.

  6. Adaptive sports ankle prosthetics. Interview by Sarah A. Curran.

    PubMed

    Lyle, David K

    2012-09-01

    Participating in sport at all levels is gaining a dedicated following and this is also apparent in individuals with an amputation. Currently, there is a wide variety of ankle prostheses available which attempt to provide function, control, and comfort, as well as good aesthetic appeal. Participation in sport, however, increases the demands placed upon ankle prostheses. This can compromise function and performance, and constrain the opportunities of participation in various outdoor and water sports. In acknowledging this limitation and the need to develop more versatile ankle prostheses, this article introduces the evolution of a prototype ankle prosthesis referred to as "Adaptive Sports Ankle." The ankle prosthesis, which is compatible with any foot pyramid adapter, offers the same range of motion as the normal human ankle joint and is made up of components that are chemical and corrosion resistant. These design features that are specifically created to accommodate below-the-knee amputees provide an ideal prosthesis for those wishing to lead an active lifestyle and participate in aquatic (i.e. swimming, surfing, and scuba diving), snowboarding, and equestrian activities. Although it is acknowledged that there is a need to establish research on the Adaptive Sports Ankle, its introduction to the market will enhance and expand opportunities of those individuals with a lower limb amputation to lead an active and healthy lifestyle.

  7. Anthropometry of the proximal tibia of patients with knee arthritis in Shanghai.

    PubMed

    Liu, Zhihong; Yuan, Gaoxiang; Zhang, Weibin; Shen, Yuhui; Deng, Lianfu

    2013-05-01

    We measured the resected bony surface of the proximal tibia from reconstructed 3D models of the 179 arthritis knees using CT data. We found that the mediolateral (ML) dimension (69.6 ± 9.2 mm) and anteroposterior (AP) dimension (46.1 ± 6.1 mm) were less than those of Westerners. It was observed the medial anteroposterior (MAP) dimension (47.1 ± 7.2 mm) was much larger and closer to middle point of ML dimension than lateral anteroposterior (LAP) dimension (42.9 ± 6.3 mm). The aspect ratio (AR) (1.5 ± 0.07) was constant in Shanghai population. Only half of the prostheses we used in clinic mostly matched the resected bony surface of Shanghai population very well in ML, AP and AR dimension. Copyright © 2013 Elsevier Inc. All rights reserved.

  8. Differential bacterial load on components of total knee prosthesis in patients with prosthetic joint infection.

    PubMed

    Holinka, Johannes; Pilz, Magdalena; Hirschl, Alexander M; Graninger, Wolfgang; Windhager, Reinhard; Presterl, Elisabeth

    2012-10-01

    The purpose of our study was to evaluate and quantify the bacterial adherence on different components of total knee prosthesis with the sonication culture method. Explanted components of all patients with presumptive prosthetic or implant infection were treated by sonication separately in sterile containers to dislodge the adherent bacteria from the surfaces and cultured. The bacterial load of the different knee components (femur, tibia, PE-inlay and patella) was evaluated by counting of colony-forming units (CFU) dislodged from the components surfaces using the sonication culture method. Overall, 27 patients had positive sonication cultures of explanted total knee prostheses. Microorganisms were detected from 88 of 100 explanted components. Twenty femoral components were culture positive and 7 negative, 23 tibial components as well as 23 polyethylene (PE) platforms had positive microorganism detection from the surface. Staphylococcus epidermidis adhered to the highest number of components whereas Staphylococcus aureus yielded the highest load of CFU in the sonication cultures. Although not significant, PE-inlays and tibial components were most often affected. The highest CFU count was detected in polyethylene components. The sonication culture method is a reliable method to detect bacteria from the components. Additionally, the results demonstrate that bacterial adherence is not affecting a single component of knee prosthesis only. Thus, in septic revision surgery partial prosthetic exchange or exchange of single polyethylene components alone may be not sufficient.

  9. Manufacturing conditioned roughness and wear of biomedical oxide ceramics for all-ceramic knee implants

    PubMed Central

    2013-01-01

    Background Ceramic materials are used in a growing proportion of hip joint prostheses due to their wear resistance and biocompatibility properties. However, ceramics have not been applied successfully in total knee joint endoprostheses to date. One reason for this is that with strict surface quality requirements, there are significant challenges with regard to machining. High-toughness bioceramics can only be machined by grinding and polishing processes. The aim of this study was to develop an automated process chain for the manufacturing of an all-ceramic knee implant. Methods A five-axis machining process was developed for all-ceramic implant components. These components were used in an investigation of the influence of surface conformity on wear behavior under simplified knee joint motion. Results The implant components showed considerably reduced wear compared to conventional material combinations. Contact area resulting from a variety of component surface shapes, with a variety of levels of surface conformity, greatly influenced wear rate. Conclusions It is possible to realize an all-ceramic knee endoprosthesis device, with a precise and affordable manufacturing process. The shape accuracy of the component surfaces, as specified by the design and achieved during the manufacturing process, has a substantial influence on the wear behavior of the prosthesis. This result, if corroborated by results with a greater sample size, is likely to influence the design parameters of such devices. PMID:23988155

  10. Manufacturing conditioned roughness and wear of biomedical oxide ceramics for all-ceramic knee implants.

    PubMed

    Turger, Anke; Köhler, Jens; Denkena, Berend; Correa, Tomas A; Becher, Christoph; Hurschler, Christof

    2013-08-29

    Ceramic materials are used in a growing proportion of hip joint prostheses due to their wear resistance and biocompatibility properties. However, ceramics have not been applied successfully in total knee joint endoprostheses to date. One reason for this is that with strict surface quality requirements, there are significant challenges with regard to machining. High-toughness bioceramics can only be machined by grinding and polishing processes. The aim of this study was to develop an automated process chain for the manufacturing of an all-ceramic knee implant. A five-axis machining process was developed for all-ceramic implant components. These components were used in an investigation of the influence of surface conformity on wear behavior under simplified knee joint motion. The implant components showed considerably reduced wear compared to conventional material combinations. Contact area resulting from a variety of component surface shapes, with a variety of levels of surface conformity, greatly influenced wear rate. It is possible to realize an all-ceramic knee endoprosthesis device, with a precise and affordable manufacturing process. The shape accuracy of the component surfaces, as specified by the design and achieved during the manufacturing process, has a substantial influence on the wear behavior of the prosthesis. This result, if corroborated by results with a greater sample size, is likely to influence the design parameters of such devices.

  11. Benefits for Adults with Transfemoral Amputations and Peripheral Artery Disease Using Microprocessor Compared with Nonmicroprocessor Prosthetic Knees.

    PubMed

    Wong, Christopher Kevin; Rheinstein, John; Stern, Michelle A

    2015-10-01

    Approximately 50% of people with leg amputation fall annually. Evidence suggests that microprocessor knees (MK) may decrease falls and improve prosthetic function in people with traumatic amputations. This study explored whether adults with transfemoral amputations and peripheral artery disease would have reduced falls and improved balance confidence, balance, and walking ability when using prostheses with MK compared with non-MK. This was a prospective cohort study. Eight subjects averaged 60.8 ± 11.3 yrs or age and 9.5 ± 16.1 yrs since first amputation. Four were K1-K2-level and four were K3-level functional walkers; only Houghton prosthetic use score was different between K1-K2 and K3 walkers (P = 0.03). After 48.3 ± 38.1 wks of acclimation using MK, subjects demonstrated improvements in fear of falling, balance confidence, Timed Up-and-Go time, and rate of falls (P < 0.05). The improvements in fear of falling, balance confidence, and rate of falls had large effect sizes (d > 0.80). Average decreased Timed Up-and-Go time (12.3 secs) had a medium effect size (d = 0.34). Decreases in the number of falls correlated with faster Timed Up-and-Go speed (ρ = -0.76) and greater balance confidence (ρ = 0.83). People with peripheral artery disease and transfemoral amputations had fewer falls and improved balance confidence and walking performance when using prostheses with MK.

  12. Comparison of the low contact stress and press fit condylar rotating-platform mobile-bearing prostheses in total knee arthroplasty: a prospective randomized study.

    PubMed

    Kim, Young-Hoo; Kim, Jun-Shik; Park, Jang-Won; Joo, Jong-Hwan

    2011-06-01

    To our knowledge, no study to date has compared the clinical results of posterior cruciate-sacrificing mobile-bearing total knee replacements with those of posterior-stabilized mobile-bearing total knee replacements in the same patients. The purpose of the present study was to compare the clinical and radiographic results of these two designs. We hypothesized that the results would be better for knees treated with the posterior-stabilized mobile-bearing prosthesis. The present study consisted of a consecutive series of 107 female patients (mean age, 66.8 years) who underwent bilateral simultaneous total knee arthroplasty at the same surgical setting. All of these patients received a posterior cruciate-sacrificing mobile-bearing prosthesis in one knee and a posterior-stabilized mobile-bearing prosthesis in the contralateral knee. At the time of each follow-up (mean, 7.4 years; range, seven to 7.6 years), the patients were assessed clinically. The mean postoperative Knee Society knee score (96 compared with 97 points) and Hospital for Special Surgery knee score (93 compared with 94 points) were similar between the two groups. At the time of the latest follow-up, the average range of motion was 127.7° (range, 70° to 150°) in the knees with a posterior cruciate-sacrificing mobile-bearing prosthesis and 132.4° (range, 90° to 150°) in the knees with a posterior-stabilized mobile-bearing prosthesis. With a margin of error of the manual measurement of 5°, this difference was not significant. The estimated survival rate was 97.2% (95% confidence interval, 91% to 99%) at seven years in the posterior-cruciate sacrificing mobile-bearing prosthesis group and 98.1% (95% confidence interval, 92% to 99%) at seven years in the posterior-stabilized mobile-bearing prosthesis group. After a minimum duration of follow-up of seven years, we found no significant differences between the two groups with regard to the clinical and radiographic results, including knee range of motion.

  13. The robustness and accuracy of in vivo linear wear measurements for knee prostheses based on model-based RSA.

    PubMed

    van Ijsseldijk, E A; Valstar, E R; Stoel, B C; Nelissen, R G H H; Reiber, J H C; Kaptein, B L

    2011-10-13

    Accurate in vivo measurements methods of wear in total knee arthroplasty are required for a timely detection of excessive wear and to assess new implant designs. Component separation measurements based on model-based Roentgen stereophotogrammetric analysis (RSA), in which 3-dimensional reconstruction methods are used, have shown promising results, yet the robustness of these measurements is unknown. In this study, the accuracy and robustness of this measurement for clinical usage was assessed. The validation experiments were conducted in an RSA setup with a phantom setup of a knee in a vertical orientation. 72 RSA images were created using different variables for knee orientations, two prosthesis types (fixed-bearing Duracon knee and fixed-bearing Triathlon knee) and accuracies of the reconstruction models. The measurement error was determined for absolute and relative measurements and the effect of knee positioning and true seperation distance was determined. The measurement method overestimated the separation distance with 0.1mm on average. The precision of the method was 0.10mm (2*SD) for the Duracon prosthesis and 0.20mm for the Triathlon prosthesis. A slight difference in error was found between the measurements with 0° and 10° anterior tilt. (difference=0.08mm, p=0.04). The accuracy of 0.1mm and precision of 0.2mm can be achieved for linear wear measurements based on model-based RSA, which is more than adequate for clinical applications. The measurement is robust in clinical settings. Although anterior tilt seems to influence the measurement, the size of this influence is low and clinically irrelevant. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. Customized versus Patient-Sized Cruciate-Retaining Total Knee Arthroplasty: An In Vivo Kinematics Study Using Mobile Fluoroscopy.

    PubMed

    Zeller, Ian M; Sharma, Adrija; Kurtz, William B; Anderle, Mathew R; Komistek, Richard D

    2017-04-01

    Historically, knee arthroplasties have been designed using average patient anatomy. Recent advances in imaging and manufacturing have facilitated the development of customized prostheses designed to fit the unique shape of individual patients. The purpose of this study is to determine if improving implant design through customized total knee arthroplasty (TKA) improves kinematic function. Using state-of-the-art mobile fluoroscopy, tibiofemoral kinematics were analyzed for 24 subjects with a customized individually made (CIM), cruciate-retaining TKA, and 14 subjects having an asymmetric condylar cruciate-retaining TKA. Subjects performed a weight-bearing deep knee bend and a rise from a seated position. Each patient was evaluated for weight-bearing range of motion, femorotibial translation, femorotibial axial rotation, and condylar liftoff occurrence. Subjects having a CIM TKA experienced greater weight-bearing knee flexion compared with the traditional posterior cruciate-retaining (PCR) TKA design. During flexion, the CIM TKA subjects consistently exhibited more posterior femoral rollback than the traditional PCR TKA subjects. The CIM TKA was found to have statistically greater axial rotation compared with the traditional PCR TKA (P = .05). Of note, only the CIM TKA patients experienced femoral internal rotation at full extension, as exhibited in a normal knee. Compared with the traditional PCR TKA, the CIM TKAs demonstrated minimal occurrences of paradoxical sliding and reverse rotation during flexion and extension. The CIM TKA subjects showed minimal liftoff and hence better stability in earlyflexion to midflexion compared with the traditional PCR subjects. The CIM TKA demonstrated kinematics more similar to a normal knee. Therefore, using customized implant technology through CIM TKA designs affords benefits including more normal motion compared with a traditional PCR TKA. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. The effect of posterior tibial slope on knee flexion in posterior-stabilized total knee arthroplasty.

    PubMed

    Shi, Xiaojun; Shen, Bin; Kang, Pengde; Yang, Jing; Zhou, Zongke; Pei, Fuxing

    2013-12-01

    To evaluate and quantify the effect of the tibial slope on the postoperative maximal knee flexion and stability in the posterior-stabilized total knee arthroplasty (TKA). Fifty-six patients (65 knees) who had undergone TKA with the posterior-stabilized prostheses were divided into the following 3 groups according to the measured tibial slopes: Group 1: ≤4°, Group 2: 4°-7° and Group 3: >7°. The preoperative range of the motion, the change in the posterior condylar offset, the elevation of the joint line, the postoperative tibiofemoral angle and the preoperative and postoperative Hospital for Special Surgery (HSS) scores were recorded. The tibial anteroposterior translation was measured using the Kneelax 3 Arthrometer at both the 30° and the 90° flexion angles. The mean values of the postoperative maximal knee flexion were 101° (SD 5), 106° (SD 5) and 113° (SD 9) in Groups 1, 2 and 3, respectively. A significant difference was found in the postoperative maximal flexion between the 3 groups (P < 0.001). However, no significant differences were found between the 3 groups in the postoperative HSS scores, the changes in the posterior condylar offset, the elevation of the joint line or the tibial anteroposterior translation at either the 30° or the 90° flexion angles. A 1° increase in the tibial slope resulted in a 1.8° flexion increment (r = 1.8, R (2) = 0.463, P < 0.001). An increase in the posterior tibial slope can significantly increase the postoperative maximal knee flexion. The tibial slope with an appropriate flexion and extension gap balance during the operation does not affect the joint stability.

  16. Anteroposterior translation and range of motion after total knee arthroplasty using posterior cruciate ligament-retaining versus posterior cruciate ligament-substituting prostheses.

    PubMed

    Ishii, Yoshinori; Noguchi, Hideo; Sato, Junko; Sakurai, Tetsuya; Toyabe, Shin-Ichi

    2017-11-01

    It is still controversial whether anteroposterior (AP) translation magnitude after total knee arthroplasty (TKA) affects clinical outcomes, particularly range of motion (ROM). This study examined the following two questions: (1) are AP translations at the mid- and long-term follow-up different for knees within the same patient treated with posterior cruciate ligament-retaining (PCLR) versus posterior cruciate ligament-substituting (PCLS) mobile-bearing TKA prosthesis designs? (2) Is the ROM at the mid- and long-term follow-up for knees treated with PCLR and PCLS designs correlated with the AP translation? Thirty-seven patients undergoing sequential bilateral TKA for osteoarthritis were prospectively enrolled. Patients received a PCLR implant in one knee and a PCLS implant in the other and were followed-up for an average 9.8 ± 3.2 years. The AP translations at 30° and 75° of knee flexion and the ROM of both knees were assessed. The implant design (p < 0.001), but not flexion angle (n.s.), had a significant effect on AP translation. AP translation values were larger in PCLR knees than in PCLS knees at both flexion angles (p < 0.0001). The ROM at the final follow-up in the two implant designs was similar (both 115°, n.s.). There was a weak correlation between ROM and AP translation at 30° in the PCLR knees (r = 0.397, p = 0.015), but no correlation at 75° or in the PCLS knees. Differently constrained prosthesis designs resulted in significantly different AP translational values within the same patient. This indicates that achieving good clinical outcomes and ROM after TKA may not be strongly influenced by the specifics of each patient's anatomical characteristics, but instead by knee constrainment. Clinically, this means that surgeons should familiarize themselves with the AP translation of the implant being used, as this may be the most important factor for optimizing outcomes after mobile-bearing TKA. Level of evidence II, prospective, comparative study.

  17. A New Device for Percutaneous Elevation of the Depressed Fractures of Tibial Condyles

    PubMed Central

    Ravindranath, V.S.; Kumar, Madhusudan; Murthy, G.V.S.

    2012-01-01

    Introduction: Monocondylar tibia plateau fractures with non-comminuted fragments can be treated using percutaneous screws. Currently indirect methods of reduction are used and thus the technique is limited to fragments with less than 5 mm depression. The first author has designed a device for direct elevation and reduction of the fragments thus potentially expanding the indications of percutaneous screws to fragments with >5mm depression Technical Note: A total of ten cases were treated by this method of percutaneous elevation of the depressed fractures of lateral condyles of the Tibia using this device. Device was inserted through a bony window on the anteromedial surface of tibia. The inner piston of the device in slowly hammered inside thus elevating the depressed fragment. Elevation of fragment could be achieved in all the cases. The fractures were fixed with cancellous screws applied percutaneously. There were no cases with loss of fixation or subsidence of the fragment. All cases achieved radiological union and have good knee function at follow up Conclusion: The new device is able to elevate unicondylar tibia plateau fragments with no subsidence or loss of fixation in our series. A longer follow up in a larger sample will be needed to establish the technique. PMID:27298860

  18. Migration and clinical outcome of mobile-bearing versus fixed-bearing single-radius total knee arthroplasty.

    PubMed

    Van Hamersveld, Koen T; Marang-Van De Mheen, Perla J; Van Der Heide, Huub J L; Van Der Linden-Van Der Zwaag, Henrica M J; Valstar, Edward R; Nelissen, Rob G H H

    2018-04-01

    Background and purpose - Mobile-bearing total knee prostheses (TKPs) were developed in the 1970s in an attempt to increase function and improve implant longevity. However, modern fixed-bearing designs like the single-radius TKP may provide similar advantages. We compared tibial component migration measured with radiostereometric analysis (RSA) and clinical outcome of otherwise similarly designed cemented fixed-bearing and mobile-bearing single-radius TKPs. Patients and methods - RSA measurements and clinical scores were assessed in 46 randomized patients at baseline, 6 months, 1 year, and annually thereafter up to 6 years postoperatively. A linear mixed-effects model was used to analyze the repeated measurements. Results - Both groups showed comparable migration (p = 0.3), with a mean migration at 6-year follow-up of 0.90 mm (95% CI 0.49-1.41) for the fixed-bearing group compared with 1.22 mm (95% CI 0.75-1.80) for the mobile-bearing group. Clinical outcomes were similar between groups. 1 fixed-bearing knee was revised for aseptic loosening after 6 years and 2 knees (1 in each group) were revised for late infection. 2 knees (1 in each group) were suspected for loosening due to excessive migration. Another mobile-bearing knee was revised after an insert dislocation due to failure of the locking mechanism 6 weeks postoperatively, after which study inclusion was preliminary terminated. Interpretation - Fixed-bearing and mobile-bearing single-radius TKPs showed similar migration. The latter may, however, expose patients to more complex surgical techniques and risks such as insert dislocations inherent to this rotating-platform design.

  19. An electromechanical swing-phase-controlled prosthetic knee joint for conversion of physiological energy to electrical energy: feasibility study.

    PubMed

    Andrysek, Jan; Chau, Gilbert

    2007-12-01

    Microprocessor-controlled prostheses facilitate a more natural and efficient gait for individuals with above-knee amputations by continually adjusting the level of swing-phase damping. One caveat associated with these technologies is that the user must charge the onboard batteries on a daily basis. It is, therefore, the aim of this study to examine the feasibility of using an electromechanical system to provide prosthetic swing-phase damping and, concomitantly, the function of converting physiological energy that is normally dissipated during the swing phase, to electrical energy. Gait data from a single subject and data from a kinematic simulator were used to develop an empirical model. The findings in this study indicate that an electromagnetic system has appropriate characteristics for use in swing-phase control and also has the potential to recover energy under particular conditions.

  20. Evaluation of a commercial multiplex PCR (Unyvero i60®) designed for the diagnosis of bone and joint infections using prosthetic-joint sonication.

    PubMed

    Prieto-Borja, Laura; Rodriguez-Sevilla, Graciela; Auñon, Alvaro; Pérez-Jorge, Concepción; Sandoval, Enrique; Garcia-Cañete, Joaquín; Gadea, Ignacio; Fernandez-Roblas, Ricardo; Blanco, Antonio; Esteban, Jaime

    2017-04-01

    The development of sonication protocols over the last few years has improved the sensitivity of conventional cultures for the diagnosis of prosthetic-joint infection (PJI). However, the development of a new, specifically designed kit for the molecular diagnosis of PJI could provide a major improvement in this field. Prostheses retrieved from patients who underwent implant removal from May 2014 to May 2015 were sent for culture, and processed according to a previously defined protocol that included sonication. Furthermore, 180 microlitres of sonication fluid were used to carry out the multiplex PCR test (Unyvero i60 system ® ). A comparison of the sensitivity, specificity, positive (PPV) and negative (NPV) predictive value, was performed. The study was approved by the Clinical Research Ethics Committee. The analysis included 88 prostheses from 68 patients (1.29 prostheses/patient). The type of prostheses studied were knee (n=55), total hip (n=26), partial hip (n=5), and shoulder (n=2). Twenty-nine patients were diagnosed with a PJI (15 delayed, 12 acute, and 2 haematogenous infections). In 24 cases, the result of the PCR was positive, all but 1 corresponding to patients with clinical criteria of PJI. Nine resistance mechanisms were detected from 5 samples. The Unyvero i60 system ® showed slightly better results than traditional culture in terms of specificity and PPV. The Unyvero i60 system ® may play a role in rapid diagnosis of PJI, due to its high specificity and PPV. However, despite these results, cultures have to be performed to detect organisms not detected by the system. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  1. In vitro method for assessing the biomechanics of the patellofemoral joint following total knee arthroplasty.

    PubMed

    Coles, L G; Gheduzzi, S; Miles, A W

    2014-12-01

    The patellofemoral joint is a common site of pain and failure following total knee arthroplasty. A contributory factor may be adverse patellofemoral biomechanics. Cadaveric investigations are commonly used to assess the biomechanics of the joint, but are associated with high inter-specimen variability and often cannot be carried out at physiological levels of loading. This study aimed to evaluate the suitability of a novel knee simulator for investigating patellofemoral joint biomechanics. This simulator specifically facilitated the extended assessment of patellofemoral joint biomechanics under physiological levels of loading. The simulator allowed the knee to move in 6 degrees of freedom under quadriceps actuation and included a simulation of the action of the hamstrings. Prostheses were implanted on synthetic bones and key soft tissues were modelled with a synthetic analogue. In order to evaluate the physiological relevance and repeatability of the simulator, measurements were made of the quadriceps force and the force, contact area and pressure within the patellofemoral joint using load cells, pressure-sensitive film, and a flexible pressure sensor. The results were in agreement with those previously reported in the literature, confirming that the simulator is able to provide a realistic physiological loading situation. Under physiological loading, average standard deviations of force and area measurements were substantially lower and comparable to those reported in previous cadaveric studies, respectively. The simulator replicates the physiological environment and has been demonstrated to allow the initial investigation of factors affecting patellofemoral biomechanics following total knee arthroplasty. © IMechE 2014.

  2. Anti-gravity treadmills are effective in reducing knee forces.

    PubMed

    Patil, Shantanu; Steklov, Nikolai; Bugbee, William D; Goldberg, Timothy; Colwell, Clifford W; D'Lima, Darryl D

    2013-05-01

    Lower body positive pressure (LBPP) treadmills permit significant unweighting of patients and have the potential to enhance recovery following lower limb surgery. We determined the efficacy of an LBPP treadmill in reducing knee forces in vivo. Subjects, implanted with custom electronic tibial prostheses to measure forces in the knee, were tested on a treadmill housed within a LBPP chamber. Tibiofemoral forces were monitored at treadmill speeds from 1.5 mph (0.67 m/s) to 4.5 mph (2.01 m/s), treadmill incline from -10° to +10°, and four treadmill chamber pressure settings adjusted to decrease net treadmill reaction force from 100% to 25% of the subject's body weight (BW). The peak axial tibiofemoral force ranged from 5.1 times BW at a treadmill speed of 4.5 mph (2.01 m/s) and a pressure setting of 100% BW to 0.8 times BW at 1.5 mph (0.67 m/s) and a pressure setting of 25% BW. Peak knee forces were significantly correlated with walking speed and treadmill reaction force (R(2)  = 0.77, p = 0.04). The LBPP treadmill might be an effective tool in the rehabilitation of patients following lower-extremity surgery. The strong correlation between tibiofemoral force and walking speed and treadmill reaction forces allows for more precisely achieving the target knee forces desired during early rehabilitation. Copyright © 2012 Orthopaedic Research Society.

  3. Ten- to 15-year results of the Oxford Phase III mobile unicompartmental knee arthroplasty: a prospective study from a non-designer group.

    PubMed

    Lisowski, L A; Meijer, L I; Bekerom, M P J van den; Pilot, P; Lisowski, A E

    2016-10-01

    The interest in unicompartmental knee arthroplasty (UKA) for medial osteoarthritis has increased rapidly but the long-term follow-up of the Oxford UKAs has yet to be analysed in non-designer centres. We have examined our ten- to 15-year clinical and radiological follow-up data for the Oxford Phase III UKAs. Between January 1999 and January 2005 a total of 138 consecutive Oxford Phase III arthroplasties were performed by a single surgeon in 129 patients for medial compartment osteoarthritis (71 right and 67 left knees, mean age 72.0 years (47 to 91), mean body mass index 28.2 (20.7 to 52.2)). Both clinical data and radiographs were prospectively recorded and obtained at intervals. Of the 129 patients, 32 patients (32 knees) died, ten patients (12 knees) were not able to take part in the final clinical and radiological assessment due to physical and mental conditions, but via telephone interview it was confirmed that none of these ten patients (12 knees) had a revision of the knee arthroplasty. One patient (two knees) was lost to follow-up. The mean follow-up was 11.7 years (10 to 15). A total of 11 knees (8%) were revised. The survival at 15 years with revision for any reason as the endpoint was 90.6% (95% confidence interval (CI) 85.2 to 96.0) and revision related to the prosthesis was 99.3% (95% CI 97.9 to 100). The mean total Knee Society Score was 47 (0 to 80) pre-operatively and 81 (30 to 100) at latest follow-up. The mean Oxford Knee Score was 19 (12 to 40) pre-operatively and 42 (28 to 55) at final follow-up. Radiolucency beneath the tibial component occurred in 22 of 81 prostheses (27.2%) without evidence of loosening. This study supports the use of UKA in medial compartment osteoarthritis with excellent long-term functional and radiological outcomes with an excellent 15-year survival rate. Cite this article: Bone Joint J 2016;98-B(10 Suppl B):41-7. ©2016 Lisowski et al.

  4. [Total knee arthroplasty by lateral parapatellar approach for valgus knee].

    PubMed

    Zhou, Dian-ge; Zhang, Bin; Kou, Bo-long; Lü, Hou-shan

    2007-07-17

    To investigate the effect of lateral parapatellar approach in total knee arthroplasty (TKA) of valgus knee. Lateral parapatellar approach of total knee arthroplasty was applied in 8 patients (10 knees) with severe valgus osteoarthritis knee (bilateral in 2 cases and unilateral in 6 cases), with the valgus angle > 15 degrees , 1 male (1 knee) and 7 females (9 knee), aged 68.2 (58 - 79), 7 cases (9 knees) being of the Krackow type I and 1 case (1 knee) of the Krackow type I, I. After incision of the skin through lateral knee, ilio-tibial band was prolonged by apple pie arthroplasty. The joint capsule was cut open laterally 2 - 4 cm from the para-patellar edge. Soft tissue balance was performed by releasing I - T band in Gerdy tubercle, lateral collateral ligament and poster-lateral capsule from the femur and tibial side. Valgus angle of distal femur cutting were five degree. Whiteside line and trans-epicondylar line were used as AP rotational cutting reference. All patellar of the group were resurfaced. Capsule closure is completed with the knee flexed. The expanded deep lateral soft tissue sleeve (coronal Z-plasty) is sutured with the medial retinaculum sleeve (superficial layer). Follow-up was conducted for 19.6 months (1 - 51 months). Seven cases (9 knees) were replaced by posterior stabilized cemented prostheses (TC-Dynamic, PLUS), one case (1 knee) was replaced by RT prosthesis (RT-PLUS(TM) Solution, PLUS). After operation, the valgus deformity of all patients was corrected and all patients could walk 100 m with or without the help of walking holders. The average range of motion (ROM) was improved from the pre-operative. 95.6 degrees (85 degrees - 110 degrees ) to the post-operative 117.1 degrees (100 degrees - 125 degrees ). The average femorotibial angle (FTA) was corrected from the pre-operative. 27.6 degrees (20 degrees - 40 degrees ) to the post-operative 6.8 degrees (5 degrees - 9 degrees ). The Knee Score System (KSS) score and functional score were improved from the pre-operative 22.7 points (9 - 48 points) and 26.5 points (12 - 55 points) to the post-operative 86.4 points (85 - 95 points) and 89.1 points (80 - 95 points) respectively. Follow-up showed that the FTA remained unchanged and the knee stability of all patients was good. Through lateral approach, "Z" plasty of the capsule can release the lateral structure and decrease the pressure of common peroneal nerve. For TKR with moderate to severe fixed valgus knee, lateral approach is an effective way to correct the deformity.

  5. Effect of the Distal Femoral Joint Line on Ligament Tensions in Flexion with Cruciate-Retaining Total Knee Prostheses.

    PubMed

    Narayanan, Rajkishen; Lenz, Nathaniel; Werner, Jordan Alexander; Cross, Michael B; Hughes, Dean; Laster, Scott; Schwarzkopf, Ran

    2018-04-13

    Proper ligament tension in knee flexion within cruciate-retaining (CR) total knee arthroplasty has long been associated with clinical success; however, traditional balancing principles have assumed that the distal femoral joint line (DFJL) affects only extension. The purpose of this study was to determine the effect DFJL may have on ligament strains and tibiofemoral kinematics of CR knee designs in flexion. A computational analysis was performed using a musculoskeletal modeling system for two different knee implants, the high-flex CR (HFCR) and guided-motion CR (GMCR). Tibiofemoral kinematics and ligament strain were measured at 90-degree knee flexion while the implants' DFJL was incrementally shifted proximally. Femoral implant position and kinematics were used to determine the femur's anteroposterior position relative to the tibia. The change in the femoral medial condyle position relative to the tibia was 0.33 mm and 0.53 mm more anterior per each 1-mm elevation of the DFJL for HFCR and GMCR, respectively. The change in the lateral condyle position was 0.20 mm more anterior and 0.06 mm more posterior for HFCR and GMCR, respectively. The strain in the lateral and medial collateral ligaments changed minimally with elevation of the DFJL. In both implants, strain increased in the anterior lateral and posterior medial bundles of the posterior collateral ligament with elevation of the DFJL, whereas strain decreased in the iliotibial band and iliotibial patellar band. Our findings suggest that DFJL affects ligament tension at 90-degree knee flexion and therefore flexion balance for CR implants. Elevating the DFJL to address tight extension space in a CR knee while flexion space is well balanced could result in increased flexion tension especially when the flexion-extension mismatch is large. To achieve balanced flexion and extension, the amount of DFJL elevation may need to be reduced. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  6. Computer-assisted hip and knee arthroplasty. Navigation and active robotic systems: an evidence-based analysis.

    PubMed

    2004-01-01

    The Medical Advisory Secretariat undertook a review of the evidence on the effectiveness and cost-effectiveness of computer assisted hip and knee arthroplasty. The two computer assisted arthroplasty systems that are the topics of this review are (1) navigation and (2) robotic-assisted hip and knee arthroplasty. Computer-assisted arthroplasty consists of navigation and robotic systems. Surgical navigation is a visualization system that provides positional information about surgical tools or implants relative to a target bone on a computer display. Most of the navigation-assisted arthroplasty devices that are the subject of this review are licensed by Health Canada. Robotic systems are active robots that mill bone according to information from a computer-assisted navigation system. The robotic-assisted arthroplasty devices that are the subject of this review are not currently licensed by Health Canada. The Cochrane and International Network of Agencies for Health Technology Assessment databases did not identify any health technology assessments on navigation or robotic-assisted hip or knee arthroplasty. The MEDLINE and EMBASE databases were searched for articles published between January 1, 1996 and November 30, 2003. This search produced 367 studies, of which 9 met the inclusion criteria. NAVIGATION-ASSISTED ARTHROPLASTY: Five studies were identified that examined navigation-assisted arthroplasty.A Level 1 evidence study from Germany found a statistically significant difference in alignment and angular deviation between navigation-assisted and free-hand total knee arthroplasty in favour of navigation-assisted surgery. However, the endpoints in this study were short-term. To date, the long-term effects (need for revision, implant longevity, pain, functional performance) are unknown.(1)A Level 2 evidence short-term study found that navigation-assisted total knee arthroplasty was significantly better than a non-navigated procedure for one of five postoperative measured angles.(2)A Level 2 evidence short-term study found no statistically significant difference in the variation of the abduction angle between navigation-assisted and conventional total hip arthroplasty.(3)Level 3 evidence observational studies of navigation-assisted total knee arthroplasty and unicompartmental knee arthroplasty have been conducted. Two studies reported that "the follow-up of the navigated prostheses is currently too short to know if clinical outcome or survival rates are improved. Longer follow-up is required to determine the respective advantages and disadvantages of both techniques."(4;5) ROBOTIC-ASSISTED ARTHROPLASTY: Four studies were identified that examined robotic-assisted arthroplasty.A Level 1 evidence study revealed that there was no statistically significant difference between functional hip scores at 24 months post implantation between patients who underwent robotic-assisted primary hip arthroplasty and those that were treated with manual implantation.(6)Robotic-assisted arthroplasty had advantages in terms of preoperative planning and the accuracy of the intraoperative procedure.(6)Patients who underwent robotic-assisted hip arthroplasty had a higher dislocation rate and more revisions.(6)Robotic-assisted arthroplasty may prove effective with certain prostheses (e.g., anatomic) because their use may result in less muscle detachment.(6)An observational study (Level 3 evidence) found that the incidence of severe embolic events during hip relocation was lower with robotic arthroplasty than with manual surgery.(7)An observational study (Level 3 evidence) found that there was no significant difference in gait analyses of patients who underwent robotic-assisted total hip arthroplasty using robotic surgery compared to patients who were treated with conventional cementless total hip arthroplasty.(8)An observational study (Level 3 evidence) compared outcomes of total knee arthroplasty between patients undergoing robotic surgery and patients who were historical controls. Brief, qualitative results suggested that there was much broader variation of angles after manual total knee arthroplasty compared to the robotic technique and that there was no difference in knee functional scores or implant position at the 3 and 6 month follow-up.(9).

  7. Computer-Assisted Hip and Knee Arthroplasty. Navigation and Active Robotic Systems

    PubMed Central

    2004-01-01

    Executive Summary Objective The Medical Advisory Secretariat undertook a review of the evidence on the effectiveness and cost-effectiveness of computer assisted hip and knee arthroplasty. The two computer assisted arthroplasty systems that are the topics of this review are (1) navigation and (2) robotic-assisted hip and knee arthroplasty. The Technology Computer-assisted arthroplasty consists of navigation and robotic systems. Surgical navigation is a visualization system that provides positional information about surgical tools or implants relative to a target bone on a computer display. Most of the navigation-assisted arthroplasty devices that are the subject of this review are licensed by Health Canada. Robotic systems are active robots that mill bone according to information from a computer-assisted navigation system. The robotic-assisted arthroplasty devices that are the subject of this review are not currently licensed by Health Canada. Review Strategy The Cochrane and International Network of Agencies for Health Technology Assessment databases did not identify any health technology assessments on navigation or robotic-assisted hip or knee arthroplasty. The MEDLINE and EMBASE databases were searched for articles published between January 1, 1996 and November 30, 2003. This search produced 367 studies, of which 9 met the inclusion criteria. Summary of Findings Navigation-Assisted Arthroplasty Five studies were identified that examined navigation-assisted arthroplasty. A Level 1 evidence study from Germany found a statistically significant difference in alignment and angular deviation between navigation-assisted and free-hand total knee arthroplasty in favour of navigation-assisted surgery. However, the endpoints in this study were short-term. To date, the long-term effects (need for revision, implant longevity, pain, functional performance) are unknown.(1) A Level 2 evidence short-term study found that navigation-assisted total knee arthroplasty was significantly better than a non-navigated procedure for one of five postoperative measured angles.(2) A Level 2 evidence short-term study found no statistically significant difference in the variation of the abduction angle between navigation-assisted and conventional total hip arthroplasty.(3) Level 3 evidence observational studies of navigation-assisted total knee arthroplasty and unicompartmental knee arthroplasty have been conducted. Two studies reported that “the follow-up of the navigated prostheses is currently too short to know if clinical outcome or survival rates are improved. Longer follow-up is required to determine the respective advantages and disadvantages of both techniques.”(4;5) Robotic-Assisted Arthroplasty Four studies were identified that examined robotic-assisted arthroplasty. A Level 1 evidence study revealed that there was no statistically significant difference between functional hip scores at 24 months post implantation between patients who underwent robotic-assisted primary hip arthroplasty and those that were treated with manual implantation.(6) Robotic-assisted arthroplasty had advantages in terms of preoperative planning and the accuracy of the intraoperative procedure.(6) Patients who underwent robotic-assisted hip arthroplasty had a higher dislocation rate and more revisions.(6) Robotic-assisted arthroplasty may prove effective with certain prostheses (e.g., anatomic) because their use may result in less muscle detachment.(6) An observational study (Level 3 evidence) found that the incidence of severe embolic events during hip relocation was lower with robotic arthroplasty than with manual surgery.(7) An observational study (Level 3 evidence) found that there was no significant difference in gait analyses of patients who underwent robotic-assisted total hip arthroplasty using robotic surgery compared to patients who were treated with conventional cementless total hip arthroplasty.(8) An observational study (Level 3 evidence) compared outcomes of total knee arthroplasty between patients undergoing robotic surgery and patients who were historical controls. Brief, qualitative results suggested that there was much broader variation of angles after manual total knee arthroplasty compared to the robotic technique and that there was no difference in knee functional scores or implant position at the 3 and 6 month follow-up.(9) PMID:23074452

  8. [Synovial fluid from aseptically failed total hip or knee arthroplasty is not toxic to osteoblasts].

    PubMed

    Gallo, J; Zdařilová, A; Rajnochová Svobodová, A; Ulrichová, J; Radová, L; Smižanský, M

    2010-10-01

    A failure of total hip or knee artroplasty is associated with an increased production of joint fluid. This contains wear particles and host cells and proteins, and is assumed to be involved in the pathogenesis of aseptic loosening and periprosthetic osteolysis. This study investigated the effect of synovial fluid from patients with aseptically failed joint prostheses on osteoblast cultures. Synovial fluid samples were obtained from patients with failed total joint prostheses (TJP; n=36) and from control patient groups (n = 16) involving cases without TJP and osteoarthritis, without TJP but with osteoarthritis, and with stable TJP. The samples were treated in the standard manner and then cultured with the SaOS-2 cell line which shows the characteristics and behaviour of osteoblasts. Each fluid sample was also examined for the content of proteins, cells and selected cytokines (IL-1ß, TNF-α, IL-6, RANKL and OPG detected by ELISA). We tested the hypothesis assuming that the fluids from failed joints would show higher cytotoxicity to osteoblast culture and we also expected higher levels of IL-1ß, TNF-α, IL-6, and RANKL in patients with TJP failure and/ or with more severe bone loss. The statistical methods used included the Kruskal-Wallis ANOVA and Mann-Whitney U test. The fluids from failed TJPs showed the highest RANKL and the lowest OPG levels resulting in the highest RANKL/OPG ratio. However, there was no evidence suggesting that the joint fluids from failed TJPs would be more toxic to osteoblast culture than the fluids from control groups. In addition, no correlation was found between the fluid levels of molecules promoting inflammation and osteoclastic activity and the extent of bone loss in the hip (in terms of Saleh's classification) or the knee (AORI classification). In fact, the fluids from failed TJPs had higher protein levels in comparison with the controls, but the difference was not significant. The finding of high RANKL levels and low OPG concentrations is in agreement with the theory of aseptic loosening and periprosthetic osteolysis. The other cytokines, particularly TNF-α and IL-1ß, were found in low levels. This can be explained by the stage of particle disease at which the samples were taken for ELISA analysis. It is probable that the level of signal molecules reflects osteolytic process activity and is therefore not constant. The reason for no correlation found between cytokine levels and the extent of bone loss may also lie in the use of therapeutic classifications of bone defects that is apparently less sensitive to the biological activity of aseptic loosening and/or periprosthetic osteolysis. Synovial fluids from failed total hip or knee joint prostheses are not toxic to osteoblast cultures. Cytotoxicity indicators and levels of pro-inflammatory and pro-osteoclastic cytokines (IL-1ß, TNF-α, IL-6, RANKL and OPG) do not correlate well with the extent of periprosthetic bone loss. Key words: total joint replacement, arthroplasty, aseptic loosening, periprosthetic osteolysis, joint fluid, SaOS-2 cell line, cytotoxicity, cytokines, RANKL, OPG.

  9. No difference between fixed- and mobile-bearing total knee arthroplasty in activities of daily living and pain: a randomized clinical trial.

    PubMed

    Amaro, Joicemar Tarouco; Arliani, Gustavo Gonçalves; Astur, Diego Costa; Debieux, Pedro; Kaleka, Camila Cohen; Cohen, Moises

    2017-06-01

    Until now, there are no definitive conclusions regarding functional differences related to middle- and long-term everyday activities and patient pain following implantation of mobile- and fixed-platform tibial prostheses. The aim of this study was to determine whether there are middle-term differences in knee function and pain in patients undergoing fixed- and mobile-bearing total knee arthroplasty (TKA). Eligible patients were randomized into two groups: the first group received TKA implantation with a fixed tibial platform (group A); the second group received TKA with a mobile tibial platform (group B). Patients were followed up (2 years), and their symptoms and limitations in daily living activities were evaluated using the Knee Outcome Survey-Activities of Daily Living Scale (ADLS), in addition to pain evaluation assessed using the pain visual analogue scale (VAS). There were no significant differences in function and symptoms in the ADLS and VAS between the study groups. The type of platform used in TKA (fixed vs. mobile) does not change the symptoms, function or pain of patients 2 years post-surgery. Although mobile TKAs may have better short-term results, at medium- and long-term follow-up they do not present important clinical differences compared with fixed-platform TKAs. This information is important so that surgeons can choose the most suitable implant for each patient. Randomized clinical trial, Level I.

  10. Biomechanical evaluation of tibial bone adaptation after revision total knee arthroplasty: A comparison of different implant systems

    PubMed Central

    Quilez, María Paz; Seral, Belen; Pérez, María Angeles

    2017-01-01

    The best methods to manage tibial bone defects following total knee arthroplasty remain under debate. Different fixation systems exist to help surgeons reconstruct knee osseous bone loss (such as tantalum cones, cement, modular metal augments, autografts, allografts and porous metaphyseal sleeves) However, the effects of the various solutions on the long-term outcome remain unknown. In the present work, a bone remodeling mathematical model was used to predict bone remodeling after total knee arthroplasty (TKA) revision. Five different types of prostheses were analyzed: one with a straight stem; two with offset stems, with and without supplements; and two with sleeves, with and without stems. Alterations in tibia bone density distribution and implant Von Mises stresses were quantified. In all cases, the bone density decreased in the proximal epiphysis and medullary channels, and an increase in bone density was predicted in the diaphysis and around stem tips. The highest bone resorption was predicted for the offset prosthesis without the supplement, and the highest bone formation was computed for the straight stem. The highest Von Mises stress was obtained for the straight tibial stem, and the lowest was observed for the stemless metaphyseal sleeves prosthesis. The computational model predicted different behaviors among the five systems. We were able to demonstrate the importance of choosing an adequate revision system and that in silico models may help surgeons choose patient-specific treatments. PMID:28886100

  11. Oxidized zirconium versus cobalt-chromium against the native patella in total knee arthroplasty: Patellofemoral outcomes.

    PubMed

    Matassi, Fabrizio; Paoli, Tommaso; Civinini, Roberto; Carulli, Christian; Innocenti, Massimo

    2017-10-01

    Oxidized zirconium (OxZr) has demonstrated excellent mechanical properties in vitro when used against articular cartilage; less coefficient of friction and less chondral damage have been found when compared with cobalt-chromium (CoCr) implants. However, controversy exists as to whether implants with a zirconium femoral component articulate safely with a native patella in total knee arthroplasty (TKA). To answer this question, the clinical and radiographic results were analysed from a group of patients who underwent a TKA with patella retention; the OxZr versus CoCr femoral components were compared. The present study prospectively evaluated 83 knees of 74 patients from 2009 to 2010. Each patient was evaluated clinically (visual analogue scale, Knee Society score, patellar score) and radiographically (long leg standing radiograph, anterior-posterior and latero-lateral projections, axial view of the patella) pre-operatively and postoperatively with a mean follow-up of 4.47years. The patellar tilt and shift, and progression of patellofemoral osteoarthritis were calculated with the axial view. There were no patient reported adverse reactions and none of the evaluated prostheses failed. Both the clinical and radiographic evaluations showed no statistically significant between-group differences. No adverse events were observed clinically or radiologically. These results justify pursuing the use of oxidized zirconium as an alternative bearing surface for a femoral component associated with patellar retention in TKA. Published by Elsevier B.V.

  12. Effects of lower limb prosthesis on activity, participation, and quality of life: a systematic review.

    PubMed

    Samuelsson, Kersti A M; Töytäri, Outi; Salminen, Anna-Liisa; Brandt, Ase

    2012-06-01

    Effects presented on the use of assistive devices such as prosthesis are often based on laboratory findings (i.e. efficacy). To summarise and evaluate findings from studies on effectiveness of lower limb prostheses for adults in real life contexts, primarily in terms of activity, participation, and quality of life (QoL) and secondarily in terms of user satisfaction, use/non-use, and/or cost-effectiveness. Systematic review. We included controlled studies and non-controlled follow-up studies including both baseline and follow-up data. Using 14 different databases supplemented with manual searches, we searched for studies published from 1998 until June 2009. Out of an initial 818 identified publications, eight met the inclusion criteria. Four studies reported on the effectiveness of a microprocessor-controlled knee (MP-knee) compared to a non-microprocessor-controlled knee (NMP-knee). Results were inconsistent except for quality of life and use/non-use, where the authors reported an improvement with the MP-knee compared to the NMP-knee. The remaining four studies included a diversity of prosthetic intervention measures and types of endpoints. Overall, there was an inconsistency in results and study quality. This review highlights the need for high-quality research studies that reflect the effectiveness of different prosthesis interventions in terms of users' daily living and QoL. Clinical guidelines are important to every practitioner. Information on expected effectiveness from assistive devices should be well founded and contain both facts about the device quality and its contribution to users' daily lives. Thus, studies based on users' experiences from prosthetic use in everyday life activities are of great importance.

  13. Dating and intimate relationships of women with below-knee amputation: an exploratory study.

    PubMed

    Mathias, Zoë; Harcourt, Diana

    2014-01-01

    This study investigates experiences of dating and intimate relationships amongst women who use a below-knee prosthesis. Four women took part in semi-structured online interviews. Transcripts were subject to interpretative phenomenological analysis (IPA). Five themes were identified: Revealing and Exposing: Disclosing the Amputation and Prosthesis; Judging and Judged: Internal Fears and Self-Doubt; Trusting and Accepting: Good Guy/Bad Guy Elimination; Taking it Further: The Need for Depth; and Realisation: Accepting and Feeling Accepted. Participants described how, despite negative feelings towards their appearance and body image, they chose not to conceal their prosthesis when dating. Rather, it was used as a means of screening potential partners in their search for deep and meaningful relationships. Realising that others were not prejudiced towards people who use a prosthetic had helped them become more comfortable with their own prosthesis. These findings suggest that facilitating contact with other below-knee amputees and, in some cases specialist support, could help those who are struggling with the challenges they face regarding dating and intimate relationships. They also highlight the need for researchers and clinicians to give more attention to these important aspects of amputees' lives. Implications for Rehabilitation Amputation can have a significant psychosocial impact for those affected. The relative invisibility of below-knee amputation and prostheses can present particular challenges for amputees looking to establish romantic and intimate relationships, particularly around when and how to disclose the limb loss to potential partners. Developing a sense of resilience to the reactions of other people can help those who have undergone below-knee amputation. Support for people affected by below-knee amputation should routinely consider their needs and concerns in relation to new and established relationships, offer specialist psychosocial input when needed and provide opportunities for support from other amputees.

  14. Migration and clinical outcome of mobile-bearing versus fixed-bearing single-radius total knee arthroplasty

    PubMed Central

    Van Hamersveld, Koen T; Marang-Van De Mheen, Perla J; Van Der Heide, Huub J L; Van Der Linden-Van Der Zwaag, Henrica M J; Valstar, Edward R; Nelissen, Rob G H H

    2018-01-01

    Background and purpose Mobile-bearing total knee prostheses (TKPs) were developed in the 1970s in an attempt to increase function and improve implant longevity. However, modern fixed-bearing designs like the single-radius TKP may provide similar advantages. We compared tibial component migration measured with radiostereometric analysis (RSA) and clinical outcome of otherwise similarly designed cemented fixed-bearing and mobile-bearing single-radius TKPs. Patients and methods RSA measurements and clinical scores were assessed in 46 randomized patients at baseline, 6 months, 1 year, and annually thereafter up to 6 years postoperatively. A linear mixed-effects model was used to analyze the repeated measurements. Results Both groups showed comparable migration (p = 0.3), with a mean migration at 6-year follow-up of 0.90 mm (95% CI 0.49–1.41) for the fixed-bearing group compared with 1.22 mm (95% CI 0.75–1.80) for the mobile-bearing group. Clinical outcomes were similar between groups. 1 fixed-bearing knee was revised for aseptic loosening after 6 years and 2 knees (1 in each group) were revised for late infection. 2 knees (1 in each group) were suspected for loosening due to excessive migration. Another mobile-bearing knee was revised after an insert dislocation due to failure of the locking mechanism 6 weeks postoperatively, after which study inclusion was preliminary terminated. Interpretation Fixed-bearing and mobile-bearing single-radius TKPs showed similar migration. The latter may, however, expose patients to more complex surgical techniques and risks such as insert dislocations inherent to this rotating-platform design. PMID:29448880

  15. [ANALYSIS OF IMPLANT-RELATED COMPLICATIONS AFTER HINGE KNEE REPLACEMENT FOR TUMORS AROUND THE KNEE].

    PubMed

    Li, Dong; Ma, Huanzhi; Zhang, Wei; Sun, Chengliang; Lu, Xiaoyong; Gao, Yutong; Zhou, Dongsheng

    2015-08-01

    To investigate the reasons and managements of implant-related complications after hinge knee replacement for tumors around the knee. A retrospective analysis was made on the clinical data of 96 patients undergoing hinge knee replacement between January 2000 and December 2012. There were 64 males and 32 females with the mean age of 31.0 years (range, 15-72 years). The most common tumor type was osteosarcoma (72 cases), and the second was giant cell tumor (15 cases). The tumor located at the distal femurs in 52 cases and at the proximal tibias in 44 cases. Fifteen hinge and 81 rotating hinge prostheses were used. The recurrence, metastasis, and survival were recorded. The implant-related complications were observed. The median follow-up time was 43.5 months (range, 10-156 months). Complications were observed in 21 patients (25 implant-related complications); 13 complications located at the femur and 12 complications at the tibia. The complications included aseptic loosening (8 cases), deep infection (7 cases), prosthetic breakage (4 cases), peri-prosthetic fracture (2 cases), and dislocation (4 cases). Most deep infection occurred within 12 months after operation (6/7), and most aseptic loosening after 40 months of operation (6/8). The rate of limb salvage was 90.6% (87/96) and the amputation rate was 9.4% (9/96). The overall survival rate of the prosthesis was 76.7% (5-year) and 47.2% (10-year). The 5-year survival rate was 82.9% for femoral prosthesis and 71.0% for tibial prosthesis, showing no significant difference (P = 0.954). Hinge knee prosthesis still has a high rate of complications. Deep infection is main reason to decrease short-term prosthetic survival rate, and aseptic loosening shortens the long-short prosthetic survival time.

  16. Does a microprocessor-controlled prosthetic knee affect stair ascent strategies in persons with transfemoral amputation?

    PubMed

    Aldridge Whitehead, Jennifer M; Wolf, Erik J; Scoville, Charles R; Wilken, Jason M

    2014-10-01

    Stair ascent can be difficult for individuals with transfemoral amputation because of the loss of knee function. Most individuals with transfemoral amputation use either a step-to-step (nonreciprocal, advancing one stair at a time) or skip-step strategy (nonreciprocal, advancing two stairs at a time), rather than a step-over-step (reciprocal) strategy, because step-to-step and skip-step allow the leading intact limb to do the majority of work. A new microprocessor-controlled knee (Ottobock X2(®)) uses flexion/extension resistance to allow step-over-step stair ascent. We compared self-selected stair ascent strategies between conventional and X2(®) prosthetic knees, examined between-limb differences, and differentiated stair ascent mechanics between X2(®) users and individuals without amputation. We also determined which factors are associated with differences in knee position during initial contact and swing within X2(®) users. Fourteen individuals with transfemoral amputation participated in stair ascent sessions while using conventional and X2(®) knees. Ten individuals without amputation also completed a stair ascent session. Lower-extremity stair ascent joint angles, moment, and powers and ground reaction forces were calculated using inverse dynamics during self-selected strategy and cadence and controlled cadence using a step-over-step strategy. One individual with amputation self-selected a step-over-step strategy while using a conventional knee, while 10 individuals self-selected a step-over-step strategy while using X2(®) knees. Individuals with amputation used greater prosthetic knee flexion during initial contact (32.5°, p = 0.003) and swing (68.2°, p = 0.001) with higher intersubject variability while using X2(®) knees compared to conventional knees (initial contact: 1.6°, swing: 6.2°). The increased prosthetic knee flexion while using X2(®) knees normalized knee kinematics to individuals without amputation during swing (88.4°, p = 0.179) but not during initial contact (65.7°, p = 0.002). Prosthetic knee flexion during initial contact and swing were positively correlated with prosthetic limb hip power during pull-up (r = 0.641, p = 0.046) and push-up/early swing (r = 0.993, p < 0.001), respectively. Participants with transfemoral amputation were more likely to self-select a step-over-step strategy similar to individuals without amputation while using X2(®) knees than conventional prostheses. Additionally, the increased prosthetic knee flexion used with X2(®) knees placed large power demands on the hip during pull-up and push-up/early swing. A modified strategy that uses less knee flexion can be used to allow step-over-step ascent in individuals with less hip strength.

  17. [Ankle arthrodesis with interposition graft as a salvage procedure after failed total ankle replacement].

    PubMed

    Schill, Stephan

    2007-12-01

    Restoration of painless function to the lower limb by ankle fusion after failure of total ankle arthroplasty. Loose total ankle replacement. Severe ankle destruction and axial deviation in rheumatoid patients. Severe osteoarthritis in the subtalar and ankle joints. Infected total ankle replacement. Severe arterial occlusive disease of the affected extremity. Transfibular approach to the subtalar and ankle joints. Osteotomy and resection of the distal fibula 7-8 cm proximal to the tip of the lateral malleolus. Removal of the prosthetic components, synovectomy, and revitalization of the remaining bone surface. Removal of any residual articular cartilage from the subtalar joint surfaces. Determination of the extent of bone loss and defect filling with horizontally or vertically placed tricortical and cancellous bone graft from the resected fibula and, if necessary, from the ipsilateral anterior iliac crest. Tibiotalocalcaneal arthrodesis by retrograde insertion of a retrograde locking nail. Wound closure in layers. Split below-knee cast. Mobilization with below-knee cast without weight bearing for 6 weeks. Dynamic locking of the intramedullary nail. Partial weight bearing with a walker up to 20 kg for an additional 6 weeks. Gradual increase in weight bearing in accordance with radiologic evidence of consolidation. Fitted orthopedic shoe with rocker-bottom sole, and made to measure insoles. From January 2003 to September 2006, 15 patients with infected ankle prosthesis loosening (six Thompson-Richards prostheses, eight S.T.A.R. prostheses, and one Salto prosthesis) were treated. All patients underwent tibiotalocalcaneal interposition arthrodesis with femoral nailing in retrograde technique. The average AOFAS (American Orthopaedic Foot and Ankle Society) Score was 57.9 points (35-81 points) postoperatively. One patient developed a nonunion and revision surgery will have to be performed. Another patient with delayed wound healing and skin necrosis needed plastic surgery.

  18. Validation of a measuring technique with computed tomography for cement penetration into trabecular bone underneath the tibial tray in total knee arthroplasty on a cadaver model

    PubMed Central

    2014-01-01

    Background In total knee arthroplasty (TKA), cement penetration between 3 and 5 mm beneath the tibial tray is required to prevent loosening of the tibia component. The objective of this study was to develop and validate a reliable in vivo measuring technique using CT imaging to assess cement distribution and penetration depth in the total area underneath a tibia prosthesis. Methods We defined the radiodensity ranges for trabecular tibia bone, polymethylmethacrylate (PMMA) cement and cement-penetrated trabecular bone and measured the percentages of cement penetration at various depths after cementing two tibia prostheses onto redundant femoral heads. One prosthesis was subsequently removed to examine the influence of the metal tibia prostheses on the quality of the CT images. The percentages of cement penetration in the CT slices were compared with percentages measured with photographs of the corresponding transversal slices. Results Trabecular bone and cement-penetrated trabecular bone had no overlap in quantitative scale of radio-density. There was no significant difference in mean HU values when measuring with or without the tibia prosthesis. The percentages of measured cement-penetrated trabecular bone in the CT slices of the specimen were within the range of percentages that could be expected based on the measurements with the photographs (p = 0.04). Conclusions CT scan images provide valid results in measuring the penetration and distribution of cement into trabecular bone underneath the tibia component of a TKA. Since the proposed method does not turn metal elements into artefacts, it enables clinicians to assess the width and density of the cement mantle in vivo and to compare the results of different cementing methods in TKA. PMID:25158996

  19. Different femorotibial contact points between fixed- and mobile-bearing TKAs do not show clinical impact.

    PubMed

    van Stralen, R A; Heesterbeek, P J C; Wymenga, A B

    2015-11-01

    In anteroposterior (AP)-gliding mobile-bearing total knee arthroplasty (TKA), the femoral component can theoretically slide forward resulting in a more anterior contact point, causing pain due to impingement. A lower lever arm of the extensor apparatus can also attribute to higher patella pressures and pain. The goal of this study was to determine the contact point in a cohort of mobile- and fixed-bearing TKAs, to determine whether the contact point lies more anteriorly in mobile-bearing TKA and to confirm whether this results in anterior knee pain. We used 38 fixed-bearing TKA and 40 mobile-bearing TKA from a randomized trial with straight lateral knee X-rays and measured the contact point. The functional outcome was measured by Knee Society Score at 12 months postoperatively. Pain scores were analysed using a VAS score (0-100 mm) in all patients at rest and when moving. Difficulty at rising up out of a chair was also assessed using a VAS score. The contact point in mobile-bearing TKA was situated at 59.5 % of the AP distance of the tibia and in the fixed-bearing TKA group at 66.1 % (P< 0.05). Patients with mobile- and fixed-bearing TKAs had similar knee scores, pain scores and difficulty in chair rise. No significant correlation was found between contact point and knee pain. The hypothesis of a more anterior contact point in the mobile-bearing cohort was confirmed but no correlation with functional and pain scores in this cohort could be found. The tibiofemoral contact point could not be correlated with a different clinical outcome and higher incidence of anterior knee pain. This study further adds to the knowledge on possible differences between mobile- and fixed-bearing prostheses. Next to that, bad outcomes could not be explained by CP. Case series, Level IV.

  20. Effect of Varying Posterior Cruciate Ligament (PCL) Recessions on Kinematics and Ligament Strains with Cruciate Retaining Total Knee Prostheses.

    PubMed

    Schwarzkopf, Ran; Laster, Scott K; Cross, Michael B; Lenz, Nathaniel M

    2016-04-01

    Proper ligament tension in flexion with posterior cruciate retaining (CR) total knee arthroplasty (TKA) has long been associated with clinical success. The purpose of this study was to determine the effect of varying levels of posterior cruciate ligament (PCL) release on the tibiofemoral kinematics and PCL strain. A computational analysis was performed and varying levels of PCL release were simulated. Tibiofemoral kinematics was evaluated. The maximum PCL strain was determined for each bundle to evaluate the risk of rupture based on the failure strain. The femoral AP position shifted anteriorly as the PCL stiffness was reduced. PCL strain in both bundles increased as stiffness was reduced. The model predicts that the AL bundle should not rupture for a 75% release. Risk of PM bundle rupture is greater than AL bundle. Our findings suggest that a partial PCL release impacts tibiofemoral kinematics and ligament tension and strain. The relationship is dynamic and care should be taken when seeking optimal balance intra-operatively.

  1. Orthopedic pathology of the lower extremities: scintigraphic evaluation in the thigh, knee, and leg.

    PubMed

    Etchebehere, E C; Etchebehere, M; Gamba, R; Belangero, W; Camargo, E E

    1998-01-01

    Radionuclide imaging (RI) of the osseous and nonosseous structures of the thigh, knee, and leg provide important diagnostic and prognostic information upon which the orthopedic surgeon can base treatment planning and management decisions. 99mTc-MDP scintigraphy is essential in overuse injuries such as stress fractures and shin splints. RI is important in assessing complications of trauma. It is the only imaging modality able to assess the magnitude of physeal stimulus caused by femoral fractures and to predict a favorable or unfavorable outcome of leg length by semiquantitative analysis; SPECT imaging can detect and locate decreased metabolism associated with posttraumatic closure of the physeal plate to predict growth arrest and deformities. Three-phase bone imaging (TPBI) is essential to differentiate hypervascular from avascular nonunions and follow delayed union. In osteonecrosis of the knee, bone scintigraphy precedes radiography changes even in stage l of the disease. 99mTc-MDP and 99mTc-HIG imaging are powerful tools in determining the outcomes of osteoarthritis and rheumatoid arthritis, respectively. Bone scintigraphy can also detect chronic ligament and acute and chronic meniscal lesions. The combined use of TPBI, gallium-67 citrate imaging, and indium-111 or 99mTc-HMPAO labeled leukocytes is important to diagnose and differentiate acute from chronic osteomyelitis, and to detect infected knee prostheses. Thallium-201 chloride imaging and 99mTc-sestamibi imaging have an important role in the assessment of tumor response to chemotherapy and in the quantification of tumor viability.

  2. Gender differences of the morphology of the distal femur and proximal tibia in a Korean population.

    PubMed

    Lim, Hong-Chul; Bae, Ji-Hoon; Yoon, Ji-Yeol; Kim, Seung-Ju; Kim, Jae-Gyoon; Lee, Jae-Moon

    2013-01-01

    We conducted this study to determine whether the sizes of distal femurs and proximal tibiae in Korean men and women are different, and to assess suitability of the sizes of prostheses currently used in Korea. We performed morphological analysis of proximal tibia and distal femur on 115 patients (56 male, 59 female) using MRI to investigate a gender difference. Tibial mediolateral dimension (tMAP), tibial medial anteroposterior dimension (tMAP), tibial lateral anteroposterior dimension (tLAP) femoral mediolateral dimension (fML), femoral medial anteroposterior dimension (fMAP), and femoral lateral anteroposterior dimension (fLAP) were measured. The ratio of tMAP and tLAP to tML (plateau aspect ratio, tAP/tML×100%), and that of fMAP and fLAP to fML (condylar aspect ratio, fAP/fML×100%) were calculated. The measurements were compared with the similar dimensions of four total knee implants currently used. The tML and tAP lengths showed a significant gender difference (P<0.05). The plateau aspect ratio (tMAP/tML) revealed a significant difference between male (0.74±0.05) and female (0.68±0.04, P<0.05). For morphotype of distal femur, males were found to have significantly large values (P<0.05) in the parameters, except for fLAP. With regards to the ratio of the ML width to the AP length, the women showed a narrower ML width than the men. Both genders were distributed within the range of the dimensions of the prostheses currently used prostheses. Korean population revealed that women have smaller dimensions than male counterparts. In both genders, a relatively small size of prostheses matches distal femur and proximal tibia better among the implants currently used in Korea. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Failure of total knee arthroplasty with or without patella resurfacing

    PubMed Central

    2011-01-01

    Background and purpose Patella resurfacing during primary total knee arthroplasty (TKA) is disputed and new prosthesis designs have been introduced without documentation of their survival. We assessed the impact on prosthesis survival of patella resurfacing and of prosthesis brand, based on data from the Norwegian Arthroplasty Register. Patients and methods 5 prosthesis brands in common use with and without patella resurfacing from 1994 through 2009 were included n = 11,887. The median follow-up times were 9 years for patella-resurfaced implants and 7 years for implants without patella resurfacing. For comparison of prosthesis brands, also brands in common use with only one of the two treatment options were included in the study population (n = 25,590). Cox regression analyses were performed with different reasons for revision as endpoints with adjustment for potential confounders. Results We observed a reduced overall risk of revision for patella resurfaced (PR) TKAs, but the statistical significance was borderline (RR = 0.84, p = 0.05). At 15 years, 92% of PR and 91% of patella non resurfaced (NR) prostheses were still unrevised. However, PR implants had a lower risk of revision due to pain alone (RR = 0.1, p < 0.001), but a higher risk of revision due to loosening of the tibial component (RR = 1.4, p = 0.03) and due to a defective polyethylene insert (RR = 3.2, p < 0.001). At 10 years, the survival for the reference NR brand AGC Universal was 93%. The NR brands Genesis I, Duracon, and Tricon (RR = 1.4–1.7) performed statistically significantly worse than NR AGC Universal, while the NR prostheses e.motion, Profix, and AGC Anatomic (RR = 0.1–0.7), and the PR prostheses NexGen and AGC Universal (RR = 0.4–0.5) performed statistically significantly better. LCS, NexGen, LCS Complete (all NR), and Tricon, Genesis I, LCS, and Kinemax (all PR) showed no differences in this respect from the reference brand. A lower risk of revision (crude) was found for TKAs performed after 2000 as compared to those performed earlier (RR = 0.8, p = 0.001). Interpretation Although revision risk was similar for PR and NR TKAs, we found important differences in reasons for revision. Our results also indicate that survivorship of TKAs has improved. PMID:21619502

  4. Ten-year in vivo wear measurement of a fully congruent mobile bearing unicompartmental knee arthroplasty.

    PubMed

    Price, A J; Short, A; Kellett, C; Beard, D; Gill, H; Pandit, H; Dodd, C A F; Murray, D W

    2005-11-01

    Polyethylene particulate wear debris continues to be implicated in the aetiology of aseptic loosening following knee arthroplasty. The Oxford unicompartmental knee arthroplasty employs a spherical femoral component and a fully congruous meniscal bearing to increase contact area and theoretically reduce the potential for polyethylene wear. This study measures the in vivo ten-year linear wear of the device, using a roentgenstereophotogrammetric technique. In this in vivo study, seven medial Oxford unicompartmental prostheses, which had been implanted ten years previously were studied. Stereo pairs of radiographs were acquired for each patient and the films were analysed using a roentgen stereophotogrammetric analysis calibration and a computer-aided design model silhouette-fitting technique. Penetration of the femoral component into the original volume of the bearing was our estimate of linear wear. In addition, eight control patients were examined less than three weeks post-insertion of an Oxford prosthesis, where no wear would be expected. The control group showed no measured wear and suggested a system accuracy of 0.1 mm. At ten years, the mean linear wear rate was 0.02 mm/year. The results from this in vivo study confirm that the device has low ten-year linear wear in clinical practice. This may offer the device a survival advantage in the long term.

  5. Effect of voluntary soft tissue tension and articular conformity after total knee arthroplasty on in vivo anteroposterior displacement.

    PubMed

    Ishii, Y; Noguchi, H; Takeda, M; Kiga, H; Toyabe, S I

    2011-01-01

    The in vivo relationship between the degree of voluntary soft tissue tension and articular conformity after total knee arthroplasty (TKA) and anteroposterior (AP) displacement was simultaneously investigated by analyzing LCS prostheses (posterior cruciate ligament-sacrificing rotating platform design) in 20 knees from 20 patients. AP displacement was measured using the KT-2000 arthrometer, at 30° and 75° flexion, while patients were conscious and under anesthesia; 30° flexion was regarded as high conformity and 75° as low conformity. Mean displacements at 30° and 75° were 5.1mm and 7.0mm, respectively, in conscious patients, and 6.7 mm and 7.7 mm, respectively, in patients under anesthesia. AP displacement was significantly associated with soft tissue tension (p=0.026) and conformity (p=0.001). No interaction was observed between the two variables (p=0.193). Surgeons should recognize that AP displacement is greater in anesthetized patients than in conscious patients, regardless of the degree of conformity, and that higher conformity shows less displacement, regardless of the degree of soft tissue tension. These results may help surgeons to determine the intra-operative AP displacement required for proper postoperative displacement in the current prosthetic design. Copyright © 2009 Elsevier B.V. All rights reserved.

  6. Pain and pain-related interference in adults with lower-limb amputation: comparison of knee-disarticulation, transtibial, and transfemoral surgical sites.

    PubMed

    Behr, James; Friedly, Janna; Molton, Ivan; Morgenroth, David; Jensen, Mark P; Smith, Douglas G

    2009-01-01

    Pain and pain-related interference with physical function have not been thoroughly studied in individuals who have undergone knee-disarticulation amputations. The principal aim of this study was to determine whether individuals with knee-disarticulation amputations have worse pain and pain-related interference with physical function than do individuals with transtibial or transfemoral amputations. We analyzed cross-sectional survey data provided by 42 adults with lower-limb amputations. These individuals consisted of 14 adults reporting knee-disarticulation amputation in one limb and best-matched cases (14 reporting transfemoral amputation and 14 reporting transtibial amputation) from a larger cross-sectional sample of 472 individuals. Participants were rigorously matched based on time since amputation, reason for amputation, age, sex, diabetes diagnosis, and pain before amputation. Continuous outcome variables were analyzed by one-way analysis of variance. Categorical outcomes were analyzed by Pearson chi-square statistic. Given the relatively small sample size and power concerns, mean differences were also described by estimated effect size (Cohen's d). Of the 42 participants, 83% were male. They ranged in age from 36 to 85 (median = 55.1, standard deviation = 11.0). Most amputations were of traumatic origin (74%), and participants were on average 12.4 years from their amputations at the time of the survey. Individuals with transtibial amputation reported significantly more prosthesis use than did individuals with knee-disarticulation amputation. Amputation levels did not significantly differ in phantom limb pain, residual limb pain, back pain, and pain-related interference with physical function. Estimates of effect size, however, indicated that participants with knee-disarticulation amputation reported less phantom limb pain, phantom limb pain-related interference with physical function, residual limb pain, residual limb pain-related interference with physical function, and back pain-related interference with physical function than did participants with transtibial or transfemoral amputations. This study demonstrated that patients with knee-disarticulation amputation used prostheses significantly less than did patients with transtibial amputation. However, no evidence was found that patients with knee-disarticulation amputation have worse outcomes in terms of pain and pain-related interference with physical function; in fact, they may have more favorable long-term outcomes.

  7. Posterior stabilized versus cruciate retaining total knee arthroplasty designs: conformity affects the performance reliability of the design over the patient population.

    PubMed

    Ardestani, Marzieh M; Moazen, Mehran; Maniei, Ehsan; Jin, Zhongmin

    2015-04-01

    Commercially available fixed bearing knee prostheses are mainly divided into two groups: posterior stabilized (PS) versus cruciate retaining (CR). Despite the widespread comparative studies, the debate continues regarding the superiority of one type over the other. This study used a combined finite element (FE) simulation and principal component analysis (PCA) to evaluate "reliability" and "sensitivity" of two PS designs versus two CR designs over a patient population. Four fixed bearing implants were chosen: PFC (DePuy), PFC Sigma (DePuy), NexGen (Zimmer) and Genesis II (Smith & Nephew). Using PCA, a large probabilistic knee joint motion and loading database was generated based on the available experimental data from literature. The probabilistic knee joint data were applied to each implant in a FE simulation to calculate the potential envelopes of kinematics (i.e. anterior-posterior [AP] displacement and internal-external [IE] rotation) and contact mechanics. The performance envelopes were considered as an indicator of performance reliability. For each implant, PCA was used to highlight how much the implant performance was influenced by changes in each input parameter (sensitivity). Results showed that (1) conformity directly affected the reliability of the knee implant over a patient population such that lesser conformity designs (PS or CR), had higher kinematic variability and were more influenced by AP force and IE torque, (2) contact reliability did not differ noticeably among different designs and (3) CR or PS designs affected the relative rank of critical factors that influenced the reliability of each design. Such investigations enlighten the underlying biomechanics of various implant designs and can be utilized to estimate the potential performance of an implant design over a patient population. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  8. Early results of patellofemoral inlay resurfacing arthroplasty using the HemiCap Wave prosthesis.

    PubMed

    Patel, Akash; Haider, Zakir; Anand, Amarjit; Spicer, Dominic

    2017-01-01

    Common surgical treatment options for isolated patellofemoral osteoarthritis include arthroscopic procedures, total knee replacement and patellofemoral replacement. The HemiCap Wave patellofemoral resurfacing prosthesis is a novel inlay design introduced in 2009 with scarce published data on its functional outcomes. We aim to prospectively evaluate early functional outcomes and complications, for patients undergoing a novel inlay resurfacing arthroplasty for isolated patellofemoral arthrosis in an independent centre. From 2010 to 2013, 16 consecutive patients underwent patellofemoral resurfacing procedures using HemiCap Wave (Arthrosurface Inc., Franklin, Massachusetts, USA) for anterior knee pain with confirmed radiologically and/or arthroscopically isolated severe patellofemoral arthrosis. Standardized surgical technique, as recommended by the implant manufacturer, was followed. Outcome measures included range of movement, functional knee scores (Oxford Knee Score (OKS), Knee Injury and Osteoarthritis Outcome Score (KOOS) and Short Form-36 (SF-36)), radiographic disease progression, revision rates and complications. Eight men and eight women underwent patellofemoral HemiCap Wave resurfacing, with an average age of 63 years (range: 46-83). Average follow-up was 24.1 months (6-34). Overall, post-operative scores were excellent. There was a statistically significant improvement in the post-operative OKS, KOOS and SF-36 scores ( p < 0.01). One patient had radiological disease progression. One patient underwent revision for deep infection. Two other minor complications were observed and treated conservatively. The HemiCap Wave patellofemoral resurfacing prosthesis has excellent early results in terms of functional outcomes, radiological outcomes and low complication rates. At the very least, early results show that the HemiCap Wave is comparable to more established onlay prostheses. The HemiCap Wave thus provides a safe and effective surgical option in the treatment of isolated patellofemoral osteoarthritis in selected patients.

  9. The Survival of Total Knee Arthroplasty: Current Data from Registries on Tribology: Review Article.

    PubMed

    Civinini, Roberto; Carulli, Christian; Matassi, Fabrizio; Lepri, Andrea Cozzi; Sirleo, Luigi; Innocenti, Massimo

    2017-02-01

    Polyethylene (PE) wear is a major contributor to implant loosening following total knee arthroplasty (TKA), and advanced bearings in TKA are being investigated with hopes of reducing or eliminate wear-related loosening. Currently, information on knee tribology is available from national joint registries and may be the best tools to evaluate the efficacy and safety of design innovations in joint arthroplasty. We performed a review of national joint registries trying to answer the following questions: "Which is the main factor directly related to revisions rate in TKA?" and "Are there new bearing options better than conventional ones?" A review was performed of all published annual reports of National Joint Registers, as well as of the literature. The search was carried out using and comparing the National Joint Registers. Current data from registries for total knee arthroplasty indicates that age is the major factor affecting the outcome of primary total knee replacement. The 10-year cumulative revision rate for non-cross-linked PE was 5.8% and for XLPE it was 3.5%. The effect of cross-linked polyethylene was more evident in the younger patients. The survival of the oxidized zirconium (OxZr) femoral component appears better when compared to a similar age group of patients with conventional group of prostheses. Our review suggests that the revision rates are half for the OxZr components compared to conventional CoCr femoral components. Age is the most relevant single factor related to revision rate. Cross-linked PE has a statistical lower revision rate at 10 years compared to conventional PE and, in the OxZr group, the revision rate is 2 times lower than Co-Cr in the same group of age.

  10. Midterm results of treatment with a retrograde nail for supracondylar periprosthetic fractures of the femur following total knee arthroplasty.

    PubMed

    Gliatis, John; Megas, Panagiotis; Panagiotopoulos, Elias; Lambiris, Elias

    2005-03-01

    Although the short-term results of supracondylar periprosthetic fractures treated with retrograde nailing have been satisfactory, there is always a concern about the long-term survival of the prosthesis. The aim of the study was to evaluate fracture healing and knee functional outcome with a follow-up time of at least 2 years in periprosthetic fractures of the knee treated with a supracondylar nail. Cohort study. There were 9 patients with 10 periprosthetic fractures. In 1 patient, the fracture occurred intraoperatively. In the others, the time between the total knee arthroplasty and the periprosthetic fracture ranged between 2 weeks and 7 years (average time: 2.78 years). The mean follow-up was 34.5 months (25-52 months). The Western Ontario and McMaster Universities index was used to evaluate the functional result postoperatively using the paired t test as the statistical test. Fracture union was assessed with plain x-rays. All the fractures united within 3 months. One fracture united in extreme valgus (35 degrees) and was revised to a stemmed total knee replacement. There were no infections and no prosthesis loosening. The paired t test before the fracture and after the operation demonstrated no statistically significant differences; however, there was a trend toward lower functional score postoperatively. It appears that retrograde nailing is a reliable technique to treat periprosthetic supracondylar fractures. It provides adequate stability until fracture union. The morbidity of the operation is minimal, and the complication rate is low. The midterm results in our study showed that none of the prostheses required revision. In our opinion, it is the treatment of choice for a periprosthetic fracture when the prosthesis is stable.

  11. Surgical débridement and parenteral antibiotics in infected revision total knee arthroplasty.

    PubMed

    Chiu, Fang-Yao; Chen, Chuan-Mu

    2007-08-01

    Whether surgical débridement and parenteral antibiotics with prosthesis retention for infected revision TKA eradicates infection is not well established. We sought to determine the prevalence of reinfection. Between 1992 and 2003, we prospectively followed 40 consecutive patients with deep infection after revision TKA. These patients had no prosthesis loosening or malalignment. Using the classification of Tsukayama et al, 10, 20, and 10 patients had Types I (acute postoperative), II (late chronic), and III (acute hematogenous) infections, respectively. All had surgical débridement and parenteral antibiotics with retention of their existing prostheses. The patients were followed for a minimum of 3 years (range, 36-143 months). Successful implant salvage was achieved in 12 of the 40 patients (30%). However, likelihood of success depended on the type of infection: patients with Type I infections (seven of 10) and patients with Type III infections (five of 10) retained their prostheses more often than patients with Type II infections (zero of 20). We recommend early débridement and retention of the prosthesis with Type I or Type III infections in revised TKAs, but primary removal for Type II infections.

  12. Effects of a powered ankle-foot prosthesis on kinetic loading of the unaffected leg during level-ground walking

    PubMed Central

    2013-01-01

    Background People with a lower-extremity amputation that use conventional passive-elastic ankle-foot prostheses encounter a series of stress-related challenges during walking such as greater forces on their unaffected leg, and may thus be predisposed to secondary musculoskeletal injuries such as chronic joint disorders. Specifically, people with a unilateral transtibial amputation have an increased susceptibility to knee osteoarthritis, especially in their unaffected leg. Previous studies have hypothesized that the development of this disorder is linked to the abnormally high peak knee external adduction moments encountered during walking. An ankle-foot prosthesis that supplies biomimetic power could potentially mitigate the forces and knee adduction moments applied to the unaffected leg of a person with a transtibial amputation, which could, in turn, reduce the risk of knee osteoarthritis. We hypothesized that compared to using a passive-elastic prosthesis, people with a transtibial amputation using a powered ankle-foot prosthesis would have lower peak resultant ground reaction forces, peak external knee adduction moments, and corresponding loading rates applied to their unaffected leg during walking over a wide range of speeds. Methods We analyzed ground reaction forces and knee joint kinetics of the unaffected leg of seven participants with a unilateral transtibial amputation and seven age-, height- and weight-matched non-amputees during level-ground walking at 0.75, 1.00, 1.25, 1.50, and 1.75 m/s. Subjects with an amputation walked while using their own passive-elastic prosthesis and a powered ankle-foot prosthesis capable of providing net positive mechanical work and powered ankle plantar flexion during late stance. Results Use of the powered prosthesis significantly decreased unaffected leg peak resultant forces by 2-11% at 0.75-1.50 m/s, and first peak knee external adduction moments by 21 and 12% at 1.50 and 1.75 m/s, respectively. Loading rates were not significantly different between prosthetic feet. Conclusions Use of a biomimetic powered ankle-foot prosthesis decreased peak resultant force at slow and moderate speeds and knee external adduction moment at moderate and fast speeds on the unaffected leg of people with a transtibial amputation during level-ground walking. Thus, use of an ankle-foot prosthesis that provides net positive mechanical work could reduce the risk of comorbidities such as knee osteoarthritis. PMID:23758860

  13. The Effect on Long-Term Survivorship of Surgeon Preference for Posterior-Stabilized or Minimally Stabilized Total Knee Replacement: An Analysis of 63,416 Prostheses from the Australian Orthopaedic Association National Joint Replacement Registry.

    PubMed

    Vertullo, Christopher J; Lewis, Peter L; Lorimer, Michelle; Graves, Stephen E

    2017-07-05

    Controversy still exists as to the optimum management of the posterior cruciate ligament (PCL) in total knee arthroplasty. Surgeons can choose to kinematically substitute the PCL with a posterior-stabilized total knee replacement or alternatively to utilize a cruciate-retaining, also known as minimally stabilized, total knee replacement. Proponents of posterior-stabilized total knee replacement propose that the reported lower survivorship in registries when directly compared with minimally stabilized total knee replacement is due to confounders such as selection bias because of the preferential usage of posterior-stabilized total knee replacement in more complex or severe cases. In this study, we aimed to eliminate these possible confounders by performing an instrumental variable analysis based on surgeon preference to choose either posterior-stabilized or minimally stabilized total knee replacement, rather than the actual prosthesis received. Cumulative percent revision, hazard ratio (HR), and revision diagnosis data were obtained from the Australian Orthopaedic Association National Joint Replacement Registry from September 1, 1999, to December 31, 2014, for 2 cohorts of patients, those treated by high-volume surgeons who preferred minimally stabilized replacements and those treated by high-volume surgeons who preferred posterior-stabilized replacements. All patients had a diagnosis of osteoarthritis and underwent fixed-bearing total knee replacement with patellar resurfacing. At 13 years, the cumulative percent revision was 5.0% (95% confidence interval [CI], 4.0% to 6.2%) for the surgeons who preferred the minimally stabilized replacements compared with 6.0% (95% CI, 4.2% to 8.5%) for the surgeons who preferred the posterior-stabilized replacements. The revision risk for the surgeons who preferred posterior-stabilized replacements was significantly higher for all causes (HR = 1.45 [95% CI, 1.30 to 1.63]; p < 0.001), for loosening or lysis (HR = 1.93 [95% CI, 1.58 to 2.37]; p < 0.001), and for infection (HR = 1.51 [95% CI, 1.25 to 1.82]; p < 0.001). This finding was irrespective of patient age and was evident with cemented fixation and with both cross-linked polyethylene and non-cross-linked polyethylene. However, the higher revision risk was only evident in male patients. There was a 45% higher risk of revision for the patients of surgeons who preferred a posterior-stabilized total knee replacement compared with the patients of surgeons who preferred a minimally stabilized total knee replacement. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  14. Outcome of prosthesis matched and unmatched patella components in primary and revision total knee replacement.

    PubMed

    Lewis, Peter L; Gamboa, Ai E; Campbell, David G; Lorimer, Michelle

    2017-10-01

    Although knee replacements have specifically designed patella prostheses that correspond to the geometry of their femoral components, a patella prosthesis that is unmatched to the femoral component may occasionally be inserted. In revision total knee arthroplasty (TKA), an originally resurfaced patella may be left, but the femoral component revised to one that does not match the patella. Few studies have compared the outcome of matched and unmatched patella components in TKA. This study compared the primary or revision TKA outcome of procedures where patella components matched to their femoral counterparts were inserted, with procedures using patella and femoral components that were unmatched. Data on all primary and revision TKA procedures without a patella component or a matched or an unmatched patella component were obtained from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR). Revision surgery was the outcome measure. Cumulative percent revised (CPR) were calculated and Hazard ratios with p values were used to test statistical significance. In primary TKA, there were higher rates of revision where unmatched patella components were used, regardless of implant design. There was no difference in the second revision rates of unmatched versus matched patella component groups. This was evident where delayed resurfacing was carried out, and where the patella prosthesis was left alone but the femoral component was changed. All primary TKA procedures require a patella component corresponding to the femoral component if the patella is resurfaced. Conversely, revision knee arthroplasties are not affected by the use of dissimilar patella and femoral components. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Implant design influences patient outcome after total knee arthroplasty: a prospective double-blind randomised controlled trial.

    PubMed

    Hamilton, D F; Burnett, R; Patton, J T; Howie, C R; Moran, M; Simpson, A H R W; Gaston, P

    2015-01-01

    Total knee arthroplasty (TKA) is an established and successful procedure. However, the design of prostheses continues to be modified in an attempt to optimise the functional outcome of the patient. The aim of this study was to determine if patient outcome after TKA was influenced by the design of the prosthesis used. A total of 212 patients (mean age 69; 43 to 92; 131 female (62%), 81 male (32%)) were enrolled in a single centre double-blind trial and randomised to receive either a Kinemax (group 1) or a Triathlon (group 2) TKA. Patients were assessed pre-operatively, at six weeks, six months, one year and three years after surgery. The outcome assessments used were the Oxford Knee Score; range of movement; pain numerical rating scales; lower limb power output; timed functional assessment battery and a satisfaction survey. Data were assessed incorporating change over all assessment time points, using repeated measures analysis of variance longitudinal mixed models. Implant group 2 showed a significantly greater range of movement (p = 0.009), greater lower limb power output (p = 0.026) and reduced report of 'worst daily pain' (p = 0.003) over the three years of follow-up. Differences in Oxford Knee Score (p = 0.09), report of 'average daily pain' (p = 0.57) and timed functional performance tasks (p = 0.23) did not reach statistical significance. Satisfaction with outcome was significantly better in group 2 (p = 0.001). These results suggest that patient outcome after TKA can be influenced by the prosthesis used. ©2015 The British Editorial Society of Bone & Joint Surgery.

  16. Do size, shape, and alignment parameters of the femoral condyle affect the trochlear groove tracking? A morphometric study based on 3D- computed tomography models in Chinese people.

    PubMed

    Du, Zhe; Chen, Shichang; Yan, Mengning; Yue, Bing; Zeng, Yiming; Wang, You

    2017-01-06

    Our study aimed to investigate whether geometrical features (size, shape, or alignment parameters) of the femoral condyle affect the morphology of the trochlear groove. Computed tomography models of 195 femurs (97 and 98 knees from male and female subjects, respectively) were reconstructed into three-dimensional models and categorised into four types of trochlear groove morphology based on the position of the turning point in relation to the mechanical axis (types 45°, 60°, 75°, and 90°). Only subjects with healthy knees were included, whereas individuals with previous knee trauma or knee pain, soft tissue injury, osteoarthritis, or other chronic diseases of the musculoskeletal system were excluded. The size parameters were: radius of the best-fit cylinder, anteroposterior dimension of the lateral condyles (AP), and distal mediolateral dimension (ML). The shape parameters were: aspect ratio (AP/ML), arc angle, and proximal- and distal- end angles. The alignment parameters were: knee valgus physiologic angle (KVPA), mechanical medial distal femoral angle (mMDFA), and hip-knee-ankle angle (HKA). All variables were measured in the femoral condyle models, and the means for each groove type were compared using one-way analysis of variance. No significant difference among groove types was observed regarding size parameters. There were significant differences when comparing type 45° with types 60°, 75°, and 90° regarding aspect ratio and distal-end angle (p < 0.05), but not regarding proximal-end angle. There were significant differences when comparing type 90° with types 45°, 60°, and 75° regarding KVPA, mMDFA, and HKA (p < 0.05). Among size, shape, and alignment parameters, the latter two exhibited partial influence on the morphology of the trochlear groove. Shape parameters affected the trochlear groove for trochlear type 45°, for which the femoral condyle was relatively flat, whereas alignment parameters affected the trochlear groove for trochlear type 90°, showing that knees in type 90° tend to be valgus. The morphometric analysis based on trochlear groove classification may be helpful for the future design of individualized prostheses.

  17. Weight of Polyethylene Wear Particles is Similar in TKAs with Oxidized Zirconium and Cobalt-chrome Prostheses

    PubMed Central

    Kim, Jun-Shik; Huh, Wansoo; Lee, Kwang-Hoon

    2009-01-01

    Background The greater lubricity and resistance to scratching of oxidized zirconium femoral components are expected to result in less polyethylene wear than cobalt-chrome femoral components. Questions/purposes We examined polyethylene wear particles in synovial fluid and compared the weight, size (equivalent circle diameter), and shape (aspect ratio) of polyethylene wear particles in knees with an oxidized zirconium femoral component with those in knees with a cobalt-chrome femoral component. Patients and Methods One hundred patients received an oxidized zirconium femoral component in one knee and a cobalt-chrome femoral component in the other. There were 73 women and 27 men with a mean age of 55.6 years (range, 44–60 years). The minimum followup was 5 years (mean, 5.5 years; range, 5–6 years). Polyethylene wear particles were analyzed using thermogravimetric methods and scanning electron microscopy. Results The weight of polyethylene wear particles produced at the bearing surface was 0.0223 ± 0.0054 g in 1 g synovial fluid in patients with an oxidized zirconium femoral component and 0.0228 ± 0.0062 g in patients with a cobalt-chrome femoral component. Size and shape of polyethylene wear particles were 0.59 ± 0.05 μm and 1.21 ± 0.24, respectively, in the patients with an oxidized zirconium femoral component and 0.52 ± 0.03 μm and 1.27 ± 0.31, respectively, in the patients with a cobalt-chrome femoral component. Knee Society knee and function scores, radiographic results, and complication rate were similar between the knees with an oxidized zirconium and cobalt-chrome femoral component. Conclusions The weight, size, and shape of polyethylene wear particles were similar in the knees with an oxidized zirconium and a cobalt-chrome femoral component. We found the theoretical advantages of this surface did not provide the actual advantage. Level of Evidence Level I, therapeutic study. See the guidelines for Authors for a complete description of levels of evidence. PMID:19949906

  18. New Prostheses and Orthoses Step Up their Game: Motorized Knees, Robotic Hands, and Exosuits Mark Advances in Rehabilitation Technology.

    PubMed

    Allen, Summer

    2016-01-01

    Forty years ago, Les Baugh lost both of his arms in an electrical accident. With bilateral shoulder-level amputations, his options for prosthetic arms were limited. That changed two years ago, when Baugh underwent a surgical procedure at Johns Hopkins Hospital in Baltimore that allowed him to control state-of-the-art robotic arms using nerves that had been rerouted to his chest. Within ten days of training, he was able to control both arms simultaneously and move a cup from a lower shelf to a higher shelf-a task that previously had been impossible-just by thinking about how he wanted to move his arm.

  19. Gait Characteristics When Walking on Different Slippery Walkways.

    PubMed

    Whitmore, Mariah W; Hargrove, Levi J; Perreault, Eric J

    2016-01-01

    This study sought to determine the changes in muscle activity about the ankle, knee, and hip in able-bodied people walking at steady state on surfaces with different degrees of slipperiness. Muscle activity was measured through electromyographic signals from selected lower limb muscles and quantified to directly compare changes across surface conditions. Our results showed distinct changes in the patterns of muscle activity controlling each joint. Muscles controlling the ankle showed a significant reduction in activity as the surface became more slippery, presumably resulting in a compliant distal joint to facilitate full contact with the surface. Select muscles about the knee and hip showed a significant increase in activity as the surface became more slippery. This resulted in increased knee and hip flexion likely contributing to a lowering of the body's center of mass and stabilization of the proximal leg and trunk. These findings suggest a proximal-distal gradient in the control of muscle activity that could inform the future design of adaptable prosthetic controllers. Walking on a slippery surface is extremely difficult, especially for individuals with lower limb amputations because current prostheses do not allow the compensatory changes in lower limb dynamics that occur involuntarily in unimpaired subjects. With recent advances in prosthetic control, there is the potential to provide some of these compensatory changes; however, we first need to understand how able-bodied individuals modulate their gait under these challenging conditions.

  20. Hip and knee joints are more stabilized than driven during the stance phase of gait: an analysis of the 3D angle between joint moment and joint angular velocity.

    PubMed

    Dumas, R; Cheze, L

    2008-08-01

    Joint power is commonly used in orthopaedics, ergonomics or sports analysis but its clinical interpretation remains controversial. Some basic principles on muscle actions and energy transfer have been proposed in 2D. The decomposition of power on 3 axes, although questionable, allows the same analysis in 3D. However, these basic principles have been widely criticized, mainly because bi-articular muscles must be considered. This requires a more complex computation in order to determine how the individual muscle force contributes to drive the joint. Conversely, with simple 3D inverse dynamics, the analysis of both joint moment and angular velocity directions is essential to clarify when the joint moment can contribute or not to drive the joint. The present study evaluates the 3D angle between the joint moment and the joint angular velocity and investigates when the hip, knee and ankle joints are predominantly driven (angle close to 0 degrees and 180 degrees ) or stabilized (angle close to 90 degrees ) during gait. The 3D angle curves show that the three joints are never fully but only partially driven and that the hip and knee joints are mainly stabilized during the stance phase. The notion of stabilization should be further investigated, especially for subjects with motion disorders or prostheses.

  1. Direct medical costs of accidental falls for adults with transfemoral amputations.

    PubMed

    Mundell, Benjamin; Maradit Kremers, Hilal; Visscher, Sue; Hoppe, Kurtis; Kaufman, Kenton

    2017-12-01

    Active individuals with transfemoral amputations are provided a microprocessor-controlled knee with the belief that the prosthesis reduces their risk of falling. However, these prostheses are expensive and the cost-effectiveness is unknown with regard to falls in the transfemoral amputation population. The direct medical costs of falls in adults with transfemoral amputations need to be determined in order to assess the incremental costs and benefits of microprocessor-controlled prosthetic knees. We describe the direct medical costs of falls in adults with a transfemoral amputation. This is a retrospective, population-based, cohort study of adults who underwent transfemoral amputations between 2000 and 2014. A Bayesian structural time series approach was used to estimate cost differences between fallers and non-fallers. The mean 6-month direct medical costs of falls for six hospitalized adults with transfemoral amputations was US$25,652 (US$10,468, US$38,872). The mean costs for the 10 adults admitted to the emergency department was US$18,091 (US$-7,820, US$57,368). Falls are expensive in adults with transfemoral amputations. The 6-month costs of falls resulting in hospitalization are similar to those reported in the elderly population who are also at an increased risk of falling. Clinical relevance Estimates of fall costs in adults with transfemoral amputations can provide policy makers with additional insight when determining whether or not to cover a prescription for microprocessor-controlled prosthetic knees.

  2. Model-based Roentgen stereophotogrammetry of orthopaedic implants.

    PubMed

    Valstar, E R; de Jong, F W; Vrooman, H A; Rozing, P M; Reiber, J H

    2001-06-01

    Attaching tantalum markers to prostheses for Roentgen stereophotogrammetry (RSA) may be difficult and is sometimes even impossible. In this study, a model-based RSA method that avoids the attachment of markers to prostheses is presented and validated. This model-based RSA method uses a triangulated surface model of the implant. A projected contour of this model is calculated and this calculated model contour is matched onto the detected contour of the actual implant in the RSA radiograph. The difference between the two contours is minimized by variation of the position and orientation of the model. When a minimal difference between the contours is found, an optimal position and orientation of the model has been obtained. The method was validated by means of a phantom experiment. Three prosthesis components were used in this experiment: the femoral and tibial component of an Interax total knee prosthesis (Stryker Howmedica Osteonics Corp., Rutherfort, USA) and the femoral component of a Profix total knee prosthesis (Smith & Nephew, Memphis, USA). For the prosthesis components used in this study, the accuracy of the model-based method is lower than the accuracy of traditional RSA. For the Interax femoral and tibial components, significant dimensional tolerances were found that were probably caused by the casting process and manual polishing of the components surfaces. The largest standard deviation for any translation was 0.19mm and for any rotation it was 0.52 degrees. For the Profix femoral component that had no large dimensional tolerances, the largest standard deviation for any translation was 0.22mm and for any rotation it was 0.22 degrees. From this study we may conclude that the accuracy of the current model-based RSA method is sensitive to dimensional tolerances of the implant. Research is now being conducted to make model-based RSA less sensitive to dimensional tolerances and thereby improving its accuracy.

  3. All-polyethylene tibial components in distal femur limb-salvage surgery: a finite element analysis based on promising clinical outcomes.

    PubMed

    Tang, Fan; Zhou, Yong; Zhang, Wenli; Min, Li; Shi, Rui; Luo, Yi; Duan, Hong; Tu, Chongqi

    2017-04-04

    Whether all-polyethylene tibial (APT) components are beneficial to patients who received distal femur limb-salvage surgery lacks high-quality clinical follow-up and mechanical evidence. This study aimed to investigate the biomechanics of the distal femur reconstructed with APT tumor knee prostheses using finite element (FE) analysis based on our previous, promising clinical outcome. Three-dimensional FE models that use APT and metal-backed tibial (MBT) prostheses to reconstruct distal femoral bone defects were developed and input into the Abaqus FEA software version 6.10.1. Mesh refinement tests and gait simulation with a single foot both in the upright and 15°-flexion positions with mechanical loading were conducted. Stress distribution analysis was compared between APT and MBT at the two static positions. For both prosthesis types, the stress was concentrated on the junction of the stem and shaft, and the maximum stress in the femoral axis base was more than 100 Mpa. The stress on the tibial surface was relatively distributed, which was 1-19 MPa. The stress on the tibial bone-cement layer of the APT prosthesis was approximately 20 times higher than that on the MBT prosthesis in the same region. The stress on the proximal tibial cancellous bone and cortical bone of the APT prosthesis was 3-5 times greater than that of the MBT prosthesis, and it was more distributed. Although the stress of bone-cement around the APT component is relatively high, the stress was better distributed at the polyethylene-cement-bone interface in APT than in MBT prosthesis, which effectively protects the proximal tibia in distal femur tumor knee prosthesis replacement. These results should be considered when selecting the appropriate tibial component for a patient, especially under the foreseeable conditions of osteoporosis.

  4. The accuracy and precision of radiostereometric analysis in upper limb arthroplasty.

    PubMed

    Ten Brinke, Bart; Beumer, Annechien; Koenraadt, Koen L M; Eygendaal, Denise; Kraan, Gerald A; Mathijssen, Nina M C

    2017-06-01

    Background and purpose - Radiostereometric analysis (RSA) is an accurate method for measurement of early migration of implants. Since a relation has been shown between early migration and future loosening of total knee and hip prostheses, RSA plays an important role in the development and evaluation of prostheses. However, there have been few RSA studies of the upper limb, and the value of RSA of the upper limb is not yet clear. We therefore performed a systematic review to investigate the accuracy and precision of RSA of the upper limb. Patients and methods - PRISMA guidelines were followed and the protocol for this review was published online at PROSPERO under registration number CRD42016042014. A systematic search of the literature was performed in the databases Embase, Medline, Cochrane, Web of Science, Scopus, Cinahl, and Google Scholar on April 25, 2015 based on the keywords radiostereometric analysis, shoulder prosthesis, elbow prosthesis, wrist prosthesis, trapeziometacarpal joint prosthesis, humerus, ulna, radius, carpus. Articles concerning RSA for the analysis of early migration of prostheses of the upper limb were included. Quality assessment was performed using the MINORS score, Downs and Black checklist, and the ISO RSA Results - 23 studies were included. Precision values were in the 0.06-0.88 mm and 0.05-10.7° range for the shoulder, the 0.05-0.34 mm and 0.16-0.76° range for the elbow, and the 0.16-1.83 mm and 11-124° range for the TMC joint. Accuracy data from marker- and model-based RSA were not reported in the studies included. Interpretation - RSA is a highly precise method for measurement of early migration of orthopedic implants in the upper limb. However, the precision of rotation measurement is poor in some components. Challenges with RSA in the upper limb include the symmetrical shape of prostheses and the limited size of surrounding bone, leading to over-projection of the markers by the prosthesis. We recommend higher adherence to RSA guidelines and encourage investigators to publish long-term follow-up RSA studies.

  5. Metal hypersensitivity after knee arthroplasty: fact or fiction?

    PubMed

    Innocenti, Massimo; Vieri, Berti; Melani, Tommaso; Paoli, Tommaso; Carulli, Christian

    2017-06-07

    Hypersensitivity to metals in the general population has an incidence of about 15%, and in rising also for the higher number of joint replacements in the last decades. Total Knee Arthroplasty (TKA) represents the most performed orthopaedic procedure during last years, and it seems to be particularly associated with sensitization after surgery. On the other hand, there is a rising amount of patients with painful but well implanted and functioning TKAs: in certain cases, after the exclusion of the most frequent causes of failure, a condition of hypersensitivity may be found, and a revision with anallergic implants is mandatory. The present study is a review of the potential problems related to hypersensitivity in TKA, its possible diagnostic procedures, and the surgical options to date available. Medical history, patch testing, and other specific laboratory assays are useful to assess a status of metals hypersensitivity before surgery in subjects undergoing a knee replacement, or even after TKA in patients complaining pain in otherwise well implanted and aligned prostheses. However, few groups worlwide deal with such condition, and all proposed diagnostic protocols may be considered still today conjectural. On the other hand, these represent the most updated knowledge of this condition, and may be useful for both the patient and the orthopaedic surgeon. Once assessed a possible or ascertained allergy to metals, several options are available for primary andr revision knee surgery, in order to avoid the risk of hypersensitivity. A review of the recent publications on this topic and an overview of the related aspects has been made to understand a condition to date considered negligible. Hypersensitivity to metals has not to be nowadays considered a "fiction", but rather a possible preoperative risk or a postoperative cause of failure of TKA. Crucial is the information of patients and the medical history, associated in suspect cases to laboratory testings. Today in the market several knee implants are available and safe for allergic patients undergoing TKA.

  6. Unicompartmental knee arthroplasty modes of failure: wear is not the main reason for failure: a multicentre study of 418 failed knees.

    PubMed

    Epinette, J-A; Brunschweiler, B; Mertl, P; Mole, D; Cazenave, A

    2012-10-01

    This study originated from a symposium held by the French Hip and Knee Society (Société française de la hanche et du genou [SFHG]) and was carried out to better assess the distribution of causes of unicompartmental knee arthroplasty (UKA) failures, as well as cause-specific delay to onset. Our working hypothesis was that most failures were traceable to wear occurring over a period of many years. A multicentre retrospective study (25 centres) was conducted in 418 failed UKAs performed between 1978 and 2009. We determined the prevalence and time to onset of the main reasons for revision surgery based upon available preoperative findings. Additional intraoperative findings were analysed. The results were compared to those of nation wide registries to evaluate the representativeness of our study population. Times to revision surgery were short: 19% of revisions occurred within the first year and 48.5% within the first 5 years. Loosening was the main reason for failure (45%), followed by osteoarthritis progression (15%) and, finally, by wear (12%). Other reasons were technical problems in 11.5% of cases, unexplained pain in 5.5%, and failure of the supporting bone in 3.6%. The infection rate was 1.9%. Our results were consistent with those of Swedish and Australian registries. Our hypothesis was not confirmed. The short time to failure in most cases suggests a major role for surgical technique issues. Morbidity related to the implant per se may be seen as moderate and not greater than with total knee prostheses. The good agreement between our data and those of nationwide registries indicates that our population was representative. A finer analysis is needed, indicating that the establishment of a French registry would be of interest. Copyright © 2012. Published by Elsevier Masson SAS.

  7. Patellofemoral arthritis treated with resurfacing implant: Clinical outcome and complications at a minimum two-year follow-up.

    PubMed

    Zicaro, Juan Pablo; Yacuzzi, Carlos; Astoul Bonorino, Juan; Carbo, Lisandro; Costa-Paz, Matias

    2017-12-01

    This study evaluated the clinical and radiographic outcomes of a series of patients treated with an anatomic inlay resurfacing implant, with a minimum two-year follow-up. Fifteen patients underwent patellofemoral-resurfacing procedures using a HemiCAP Wave Patellofemoral Inlay Resurfacing implant from 2010 to 2013. Clinical outcomes included: Visual Analog Scale (VAS), Lysholm score, Knee Society Score (KSS), and evaluation of Kujala, and Hospital for Special Surgery Patellofemoral score (HSS-PF). The postoperative complications were analyzed. Nineteen knees were evaluated; the average follow-up was 35.2months. Fourteen were women, with an average age of 54years. The pre-operative/postoperative clinical results presented a significant improvement: VAS 8/2.5, Lysholm 31.9/85.8, KSS 39.8/82.5, Kujala 32.1/79.3 and Hospital for Special Surgery Patellofemoral score (HSS-PF) 15.9/90.6. A total of 87% of patients were either satisfied or very satisfied with the overall outcome. There were no radiographic signs of loosening. Seven postoperative complications were recorded: two presented ongoing knee pain, one postoperative stiffness, one patellar bounce due to maltracking, two ilio-tibial band syndrome, and one tibial anterior tuberosity osteotomy nonunion. Two patients underwent a total knee arthroplasty conversion and were considered a failure. None of these complications were implant related. Patellofemoral inlay resurfacing for isolated patellofemoral arthritis was an effective and safe procedure with high levels of patient satisfaction. No mechanical implant failure was seen at a minimum two-year follow-up. This implant design appeared to be an alternative to the traditional patellofemoral prostheses. Concomitant osteochondral lesions, patellofemoral dysplasia or patellar maltracking might be poor prognostic factors for this type of implant. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Treatment based on the type of infected TKA improves infection control.

    PubMed

    Kim, Young-Hoo; Choi, Yoowang; Kim, Jun-Shik

    2011-04-01

    A classification system with four types of infected TKAs has been commonly used to determine treatment, especially with regard to whether the prosthesis should be removed or retained. We asked whether (1) the classification-dictated treatment of the four types of infection after TKA would control infection and maintain functional TKA; (2) repeated débridement and two-stage TKA would further improve the infection control rate after initial treatment; and (3) fixation of TKA prosthesis to the host bone was achieved. We retrospectively reviewed 114 patients with 116 infected TKAs. We determined the infection control rate after initial treatment, repeated débridement and two-stage TKA. We evaluated the functional and radiographic results using the Knee Society and Hospital for Special Surgery knee scoring systems. The minimum followup was 2 years (mean, 5.6 years; range, 2-8 years). The overall infection control rate was 100% in all patients. All patients with early superficial postoperative infection, 94% of patients with early deep postoperative infection, 96% of patients with late chronic infection, and 86% of patients with acute hematogenous infection maintained functioning knee prosthesis at the final followup. One hundred nine of the 114 patients could walk with no or only slight pain and maintained functioning knee prostheses. These 109 patients had stable fixation of the TKA prosthesis to host bone. The techniques proposed by the classification effectively controlled infection and maintained functional TKA with firm fixation of the TKA prosthesis in most patients. Repeated débridement and two-stage TKA further improved the control of infection and functional TKA after initial treatment. Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

  9. Bicruciate-retaining Total Knee Replacement Provides Satisfactory Function and Implant Survivorship at 23 Years.

    PubMed

    Pritchett, James W

    2015-07-01

    One of the goals of a TKA is to approximate the function of a normal knee. Preserving the natural ligaments might provide a method of restoring close to normal function. Sacrifice of the ACL is common and practical during a TKA. However, this ligament is functional in more than 60% of patients undergoing a TKA and kinematic studies support the concept of bicruciate-retaining (that is, ACL-preserving) TKA; however, relatively few studies have evaluated patients treated with bicruciate-retaining TKA implants. I asked: (1) what is the long-term (minimum 20-year) survivorship, (2) what are the functional results, and (3) what are the reasons for revision of bicruciate-retaining knee arthroplasty prostheses? From January 1989 to September 1992, I performed 639 total knee replacements in 537 patients. Of these, 489 were performed in 390 patients using a bicruciate-retaining, minimally constrained device. During the period in question, this knee prosthesis was used for all patients observed intraoperatively to have an intact, functional ACL with between 15° varus and 15° valgus joint deformity. There were 234 women and 156 men with a mean age at surgery of 65 years (range, 42-84 years) and a primary diagnosis of osteoarthritis in 89%. The patella was resurfaced in all knees. The mean followup was 23 years (range, 20-24 years). At the time of this review, 199 (51%) patients had died and 31 (8%) patients were lost to followup, leaving 160 (41%) patients (214 knees) available for review. Component survivorship was determined by competing-risks analysis and Kaplan Meier survivorship analysis with revision for any reason as the primary endpoint. Patients were evaluated every 2 years to assess ROM, joint laxity, knee stability, and to determine American Knee Society scores. The Kaplan-Meier survivorship was 89% (95% CI, 82%-93%) at 23 years with revision for any reason as the endpoint. Competing-risks survivorship was 94% (95% CI, 91%%-96 %) at 23 years. At followup, the mean age of the patients was 84 years (range, 63-101 years), the mean flexion was 117° (range, 90°-130°), the mean American Knee Society score improved from a preoperative mean of 42 (range, 26-49) to 91 (range, 61-100; p < .001). Twenty-two knees in 21 patients (5.6%) were revised, most commonly because of polyethylene wear. ACL sacrifice may be an unnecessary concession during TKA. This study found satisfactory survivorship and function after more than 20 years of use for patients receiving a bicruciate-retaining TKA implant. A TKA that preserves cruciate ligaments provides a stable, well-functioning knee with a low likelihood of revision at long-term followup. Retaining both cruciate ligaments during knee arthroplasty is an attractive concept that is worth considering. Level IV, therapeutic study.

  10. Metabolics of stair ascent with a powered transfemoral prosthesis.

    PubMed

    Ledoux, E D; Lawson, B E; Shultz, A H; Bartlett, H L; Goldfarb, M

    2015-01-01

    This paper evaluates the effectiveness of a powered knee and ankle prosthesis for stair ascent through a metabolic assessment comparing energy expenditure of a single transfemoral amputee subject while ascending stairs with the powered prosthesis relative to his passive daily use device, as well as comparing the kinematics and kinetics obtained with the passive prosthesis to healthy biomechanics. The subject wore a portable system that measured pulmonary gaseous exchange rates of oxygen and carbon dioxide while he ascended stairs with each of the prostheses in alternating tests. The results indicated that the amputee's energy expenditure decreased by 32 percent while climbing with the powered prosthesis as compared to his passive one, and the kinematics and kinetics achieved were representative of healthy biomechanics.

  11. Cementless Total Knee Arthroplasty in Patients Older Than 75 Years.

    PubMed

    Newman, Jared M; Khlopas, Anton; Chughtai, Morad; Gwam, Chukwuweike U; Mistry, Jaydev B; Yakubek, George A; Harwin, Steven F; Mont, Michael A

    2017-11-01

    Some surgeons have been hesitant to use cementless fixation for total knee arthroplasty (TKA) in elderly patients due to concerns regarding successful bone biological fixation. Therefore, this study evaluated: (1) implant survivorship, (2) functional outcomes, (3) radiographic outcomes, and (4) complications in patients over 75 years of age who underwent cementless total knee arthroplasty. A total of 134 patients (142 TKAs) older than 75 years at a single institution between June 2008 and June 2014 were retrospectively reviewed. Their mean follow-up was 4 years (range: 2-8 years). The cohort consisted of 91 women and 43 men who had a mean age of 80 years (range: 76 to 88 years). The preoperative diagnoses were osteoarthritis ( n  = 107 patients), rheumatoid arthritis ( n  = 21 patients), and osteonecrosis ( n  = 6 patients). Descriptive statistics were used to calculate the means and ranges and a Kaplan-Meier analysis was performed to determine the aseptic and all cause implant survivorship. Radiographic evaluation was performed using the new Knee Society Radiographic Evaluation and Scoring System. Functional outcomes at the final follow-up as well as all medical and surgical complications were recorded for each patient. The aseptic implant survivorship was 99.3% (95% CI: 7.9-8.1), and the all cause implant survivorship was 98.6% (95% CI: 7.9-8.1). There was one aseptic revision and one septic revision. At the latest follow-up the mean Knee Society pain score was 93 points (range, 80-100 points), and the mean Knee Society function score was 84 points (range, 70-90 points). On radiographic evaluation, there were no progressive radiolucencies, subsidence, and loosening of prostheses at the latest follow-up. The use of cementless TKA demonstrated excellent survivorship, mid-term clinical and functional outcomes, as well as no progressive radiolucencies or subsidence in patients older than 75 years. In addition, there was a low rate of surgical and medical complications. Therefore, cementless TKA may be a good option for patients older than 75 years. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  12. Analysis of surface damage in retrieved carbon fiber-reinforced and plain polyethylene tibial components from posterior stabilized total knee replacements.

    PubMed

    Wright, T M; Rimnac, C M; Faris, P M; Bansal, M

    1988-10-01

    The performance of carbon fiber-reinforced ultra-high molecular weight polyethylene was compared with that of plain (non-reinforced) polyethylene on the basis of the damage that was observed on the articulating surfaces of retrieved tibial components of total knee prostheses. Established microscopy techniques for subjectively grading the presence and extent of surface damage and the histological structure of the surrounding tissues were used to evaluate twenty-six carbon fiber-reinforced and twenty plain polyethylene components that had been retrieved after an average of twenty-one months of implantation. All of the tibial components were from the same design of total knee replacement. The two groups of patients from whom the components were retrieved did not differ with regard to weight, the length of time that the component had been implanted, the radiographic position and angular alignment of the component, the original diagnosis, or the reason for removal of the component. The amounts and types of damage that were observed did not differ for the two materials. For both materials, the amount of damage was directly related to the length of time that the component had been implanted. The histological appearance of tissues from the area around the component did not differ for the two materials, except for the presence of fragments of carbon fiber in many of the samples from the areas around carbon fiber-reinforced components.

  13. Clinical, biomechanical and morphological assessment of anterior cruciate ligament Kevlar®-based artificial prosthesis in rabbit model.

    PubMed

    de la Garza-Castro, Santiago; González-Rivera, Carlos E; Vílchez-Cavazos, Félix; Morales-Avalos, Rodolfo; Barrera-Flores, Francisco J; Elizondo-Omaña, Rodrigo E; Soto-Dominguez, Adolfo; Acosta-Olivo, Carlos; Mendoza-Lemus, Oscar F

    2017-07-27

    The aim of this study was to evaluate the clinical, biomechanical and morphological characteristics of a Kevlar®-based prosthetic ligament as a synthetic graft of the anterior cruciate ligament (ACL) in an experimental animal model in rabbits. A total of 27 knees of rabbits randomly divided into 3 groups (control, ACL excision and ACL replacement with a Kevlar® prosthesis) were analyzed using clinical, biomechanical and morphological tests at 6, 12 and 18 weeks postprocedure. The mean displacement in mechanical testing was 0.73 ± 0.06 mm, 1.58 ± 0.19 mm and 0.94 ± 0.20 mm for the control, ACL excision and ACL replacement with synthetic prosthesis groups, respectively. The results showed an improvement in the stability of the knee with the use of the Kevlar® synthetic prosthesis in the biomechanical testing (p<0.05) compared with rabbits that underwent ACL excision, in addition to displacements that were larger but comparable to that in the control group (p>0.05), between the replacement group and the control group. The histological study revealed a good morphological adaptation of the synthetic material to the knee. This study proposes a new animal model for the placement and evaluation of Kevlar®-based synthetic ACL implants. The studied prosthesis showed promising behavior in the clinical and biomechanical tests and in the histological analysis. This study lays the foundation for further basic and clinical studies of artificial ACL prostheses using this material.

  14. PFC knee replacement: osteolytic failures from extreme polyethylene degradation.

    PubMed

    Casey, David; Cottrell, Jocelyn; DiCarlo, Edward; Windsor, Russell; Wright, Timothy

    2007-11-01

    Despite the long-term success of press-fit condylar (PFC) knee prostheses, premature failures caused by aggressive rapid osteolysis have been reported. To investigate why patients experience such failures, we reviewed 48 retrieved implants and surrounding tissues together with demographic and radiographic data. Polyethylene degradation was determined from density profiles taken through the retrieved inserts. We compared the histology of tissues around PFC implants with that from around failed implants of similar designs from patients matched to length of implantation, body mass index, and age. The pathologic response in PFC patients showed more widespread, dense, sheet-like cellular infiltrate, whereas in the matched patients, the infiltrate was generally scattered discontinuously. The dominant wear mode of the PFC inserts was severe delamination on the articular surfaces. Wear damage was worse with increased length of implantation and was correlated with oxidative degradation and osteolysis. Degradation and osteolysis were more severe with inserts stored longer and sterilized by gamma radiation in air. These results underscore that degradation and increased shelf life lead to osteolysis and loosening. However, they raise questions concerning the cellular reaction to the debris from PFC implants that could lead to a better general understanding of osteolysis.

  15. Survival of modern knee tumor megaprostheses: failures, functional results, and a comparative statistical analysis.

    PubMed

    Pala, Elisa; Trovarelli, Giulia; Calabrò, Teresa; Angelini, Andrea; Abati, Caterina N; Ruggieri, Pietro

    2015-03-01

    Modular megaprostheses are now the most common method of reconstruction after segmental resection of the long bones in the lower extremities. Previous studies reported variable outcome and failure rates after knee megaprosthetic reconstructions. The objectives of this study were to analyze the results of a modular tumor prosthesis after resection of bone tumor around the knee with respect to (1) survivorship; (2) failure rate; (3) comparative survivorship against different sites of reconstructions and of primary and revision implants; and (4) functional results on the Musculoskeletal Tumor Society (MSTS) scoring system. Between 2003 and 2010, 247 rotating-hinge Global Modular Reconstruction System (GMRS) knee prostheses were implanted in our institute for malignant and aggressive benign tumors. During this time, that group represented 23% of the patients who had oncologic megaprosthesis reconstruction about the knee after resection of primary or metastatic bone tumors (247 of 1086 patients). In the other 77% of cases we used other types of oncologic prostheses. Before 2003 we used the older Howmedica Modular Resection System and Kotz Modular Femur/Tibia Replacement from 2003 we used mostly the GMRS but we continued to use the HMRS in some cases such as patients with poor prognoses, elderly patients, or metastatic patients. Sites included 187 distal femurs and 60 proximal tibias. Causes of megaprosthesis failure were classified according to Henderson et al. in five types: Type 1 (soft tissue failure), Type 2 (aseptic loosening), Type 3 (structural failure), Type 4 (infection), and Type 5 (tumor progression). Followup was at a minimum oncologic followup of 2 years (mean, 4 years; range, 2-8 years). Kaplan-Meier actuarial curves of implant survival to major failures were done. Functional results were analyzed according to the MSTS II system; 223 of the 247 were available for functional scoring (81%). At latest followup, among 175 treated patients for primary reconstruction, 117 are continuously disease-free, 26 have no evidence of disease after treatment of relapse, eight are alive with disease, and 24 died from disease. The overall failure rate of the megaprostheses in our series was 29.1% (72 of 247). Type 1 failure occurred in 8.5% (21 of 247) cases, Type 2 in 5.6% (14 of 247), Type 3 in 0%, Type 4 in 9.3% (23 of 247), and Type 5 in 5.6% (14 of 247). Kaplan-Meier curve showed an overall implant survival rate for all types of failures of 70% at 4 years and 58% at 8 years. Prosthetic survivorship for revisions was 80% at 5 years and for primary reconstructions was 60% at 5 years (p = 0.013). Survivorship to infection was 95% at 5 years for revision patients and 84% at 5 years for primary patients (p = 0.475). The mean MSTS score was 84 (25.2; range, 8-30) with no difference between sites of localization (24.7 in proximal tibia versus 25.4 in distal femur reconstruction; p = 0.306). Results at a minimum of 2 years with this modular prosthesis are satisfactory in terms of survivorship (both oncologic and reconstructive) and causes and rates of failure. Although these results seem comparable with other like implants, we will continue to follow this cohort, and we believe that comparative trials among the available megaprosthesis designs are called for. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

  16. Analysis of using EMG and mechanical sensors to enhance intent recognition in powered lower limb prostheses

    NASA Astrophysics Data System (ADS)

    Young, A. J.; Kuiken, T. A.; Hargrove, L. J.

    2014-10-01

    Objective. The purpose of this study was to determine the contribution of electromyography (EMG) data, in combination with a diverse array of mechanical sensors, to locomotion mode intent recognition in transfemoral amputees using powered prostheses. Additionally, we determined the effect of adding time history information using a dynamic Bayesian network (DBN) for both the mechanical and EMG sensors. Approach. EMG signals from the residual limbs of amputees have been proposed to enhance pattern recognition-based intent recognition systems for powered lower limb prostheses, but mechanical sensors on the prosthesis—such as inertial measurement units, position and velocity sensors, and load cells—may be just as useful. EMG and mechanical sensor data were collected from 8 transfemoral amputees using a powered knee/ankle prosthesis over basic locomotion modes such as walking, slopes and stairs. An offline study was conducted to determine the benefit of different sensor sets for predicting intent. Main results. EMG information was not as accurate alone as mechanical sensor information (p < 0.05) for any classification strategy. However, EMG in combination with the mechanical sensor data did significantly reduce intent recognition errors (p < 0.05) both for transitions between locomotion modes and steady-state locomotion. The sensor time history (DBN) classifier significantly reduced error rates compared to a linear discriminant classifier for steady-state steps, without increasing the transitional error, for both EMG and mechanical sensors. Combining EMG and mechanical sensor data with sensor time history reduced the average transitional error from 18.4% to 12.2% and the average steady-state error from 3.8% to 1.0% when classifying level-ground walking, ramps, and stairs in eight transfemoral amputee subjects. Significance. These results suggest that a neural interface in combination with time history methods for locomotion mode classification can enhance intent recognition performance; this strategy should be considered for future real-time experiments.

  17. Influence of Femoral Component Design on Retrograde Femoral Nail Starting Point.

    PubMed

    Service, Benjamin C; Kang, William; Turnbull, Nathan; Langford, Joshua; Haidukewych, George; Koval, Kenneth J

    2015-10-01

    Our experience with retrograde femoral nailing after periprosthetic distal femur fractures was that femoral components with deep trochlear grooves posteriorly displace the nail entry point resulting in recurvatum deformity. This study evaluated the influence of distal femoral prosthetic design on the starting point. One hundred lateral knee images were examined. The distal edge of Blumensaat's line was used to create a ratio of its location compared with the maximum anteroposterior condylar width called the starting point ratio (SPR). Femoral trials from 6 manufacturers were analyzed to determine the location of simulated nail position in the sagittal plane compared with the maximum anteroposterior prosthetic width. These measurements were used to create a ratio, the femoral component ratio (FCR). The FCR was compared with the SPR to determine if a femoral component would be at risk for retrograde nail starting point posterior to the Blumensaat's line. The mean SPR was 0.392 ± 0.03, and the mean FCR was 0.416 ± 0.05, which was significantly greater (P = 0.003). The mean FCR was 0.444 ± 0.06 for the cruciate retaining (CR) trials and was 0.393 ± 0.04 for the posterior stabilized trials; this difference was significant (P < 0.001). The FCR for the femoral trials studied was significantly greater than the SPR for native knees and was significantly greater for CR femoral components compared with posterior stabilized components. These findings demonstrate that many total knee prostheses, particularly CR designs, are at risk for a starting point posterior to Blumensaat's line.

  18. Iatrogenic Bone and Soft Tissue Trauma in Robotic-Arm Assisted Total Knee Arthroplasty Compared With Conventional Jig-Based Total Knee Arthroplasty: A Prospective Cohort Study and Validation of a New Classification System.

    PubMed

    Kayani, Babar; Konan, Sujith; Pietrzak, Jurek R T; Haddad, Fares S

    2018-03-27

    The objective of this study was to compare macroscopic bone and soft tissue injury between robotic-arm assisted total knee arthroplasty (RA-TKA) and conventional jig-based total knee arthroplasty (CJ-TKA) and create a validated classification system for reporting iatrogenic bone and periarticular soft tissue injury after TKA. This study included 30 consecutive CJ-TKAs followed by 30 consecutive RA-TKAs performed by a single surgeon. Intraoperative photographs of the femur, tibia, and periarticular soft tissues were taken before implantation of prostheses. Using these outcomes, the macroscopic soft tissue injury (MASTI) classification system was developed to grade iatrogenic bone and soft tissue injuries. Interobserver and Intraobserver validity of the proposed classification system was assessed. Patients undergoing RA-TKA had reduced medial soft tissue injury in both passively correctible (P < .05) and noncorrectible varus deformities (P < .05); more pristine femoral (P < .05) and tibial (P < .05) bone resection cuts; and improved MASTI scores compared to CJ-TKA (P < .05). There was high interobserver (intraclass correlation coefficient 0.92 [95% confidence interval: 0.88-0.96], P < .05) and intraobserver agreement (intraclass correlation coefficient 0.94 [95% confidence interval: 0.92-0.97], P < .05) of the proposed MASTI classification system. There is reduced bone and periarticular soft tissue injury in patients undergoing RA-TKA compared to CJ-TKA. The proposed MASTI classification system is a reproducible grading scheme for describing iatrogenic bone and soft tissue injury in TKA. RA-TKA is associated with reduced bone and soft tissue injury compared with conventional jig-based TKA. The proposed MASTI classification may facilitate further research correlating macroscopic soft tissue injury during TKA to long-term clinical and functional outcomes. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. Elite long jumpers with below the knee prostheses approach the board slower, but take-off more effectively than non-amputee athletes.

    PubMed

    Willwacher, Steffen; Funken, Johannes; Heinrich, Kai; Müller, Ralf; Hobara, Hiroaki; Grabowski, Alena M; Brüggemann, Gert-Peter; Potthast, Wolfgang

    2017-11-22

    The use of technological aids to improve sport performance ('techno doping') and inclusion of Paralympic athletes in Olympic events are matters of ongoing debate. Recently, a long jumper with a below the knee amputation (BKA) achieved jump distances similar to world-class athletes without amputations, using a carbon fibre running-specific prosthesis (RSP). We show that athletes with BKA utilize a different, more effective take-off technique in the long jump, which provided the best athlete with BKA a performance advantage of at least 0.13 m compared to non-amputee athletes. A maximum speed constraint imposed by the use of RSPs would indicate a performance disadvantage for the long jump. We found slower maximum sprinting speeds in athletes with BKA, but did not find a difference in the overall vertical force from both legs of athletes with BKA compared to non-amputees. Slower speeds might originate from intrinsically lower sprinting abilities of athletes with BKA or from more complex adaptions in sprinting mechanics due to the biomechanical and morphological differences induced by RSPs. Our results suggest that due to different movement strategies, athletes with and without BKA should likely compete in separate categories for the long jump.

  20. An investigation of the inelastic behaviour of trabecular bone during the press-fit implantation of a tibial component in total knee arthroplasty.

    PubMed

    Kelly, N; Cawley, D T; Shannon, F J; McGarry, J P

    2013-11-01

    The stress distribution and plastic deformation of peri-prosthetic trabecular bone during press-fit tibial component implantation in total knee arthroplasty is investigated using experimental and finite element techniques. It is revealed that the computed stress distribution, implantation force and plastic deformation in the trabecular bone is highly dependent on the plasticity formulation implemented. By incorporating pressure dependent yielding using a crushable foam plasticity formulation to simulate the trabecular bone during implantation, highly localised stress concentrations and plastic deformation are computed at the bone-implant interface. If the pressure dependent yield is neglected using a traditional von Mises plasticity formulation, a significantly different stress distribution and implantation force is computed in the peri-prosthetic trabecular bone. The results of the study highlight the importance of: (i) simulating the insertion process of press-fit stem implantation; (ii) implementing a pressure dependent plasticity formulation, such as the crushable foam plasticity formulation, for the trabecular bone; (iii) incorporating friction at the implant-bone interface during stem insertion. Simulation of the press-fit implantation process with an appropriate pressure dependent plasticity formulation should be implemented in the design and assessment of arthroplasty prostheses. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

  1. A New Powered Lower Limb Prosthesis Control Framework Based on Adaptive Dynamic Programming.

    PubMed

    Wen, Yue; Si, Jennie; Gao, Xiang; Huang, Stephanie; Huang, He Helen

    2017-09-01

    This brief presents a novel application of adaptive dynamic programming (ADP) for optimal adaptive control of powered lower limb prostheses, a type of wearable robots to assist the motor function of the limb amputees. Current control of these robotic devices typically relies on finite state impedance control (FS-IC), which lacks adaptability to the user's physical condition. As a result, joint impedance settings are often customized manually and heuristically in clinics, which greatly hinder the wide use of these advanced medical devices. This simulation study aimed at demonstrating the feasibility of ADP for automatic tuning of the twelve knee joint impedance parameters during a complete gait cycle to achieve balanced walking. Given that the accurate models of human walking dynamics are difficult to obtain, the model-free ADP control algorithms were considered. First, direct heuristic dynamic programming (dHDP) was applied to the control problem, and its performance was evaluated on OpenSim, an often-used dynamic walking simulator. For the comparison purposes, we selected another established ADP algorithm, the neural fitted Q with continuous action (NFQCA). In both cases, the ADP controllers learned to control the right knee joint and achieved balanced walking, but dHDP outperformed NFQCA in this application during a 200 gait cycle-based testing.

  2. Highly Crosslinked-remelted versus Less-crosslinked Polyethylene in Posterior Cruciate-retaining TKAs in the Same Patients.

    PubMed

    Kim, Young-Hoo; Park, Jang-Won; Kim, Jun-Shik; Lee, June-Hyung

    2015-11-01

    Concern regarding osteolysis attributable to polyethylene wear after TKA, particularly in younger patients, has prompted the introduction of highly crosslinked-remelted polyethylene (HXLPE) for TKAs. However, few in vivo comparative results of TKAs using HXLPE and less-crosslinked polyethylene inserts in the same patients are available, regarding fracture or failure of the locking mechanism of tibial polyethylene inserts or of osteolysis in patients younger than 60 years. We wanted to determine whether (1) survivorship free from aseptic loosening in knees with HXLPE inserts was different from survivorship in knees with less-crosslinked polyethylene inserts, (2) the prevalence of fracture or failure of the locking mechanism of the tibial polyethylene insert was greater in knees with HXLPE than in those with less-crosslinked polyethylene, and (3) the proportion of patients who had osteolysis develop was greater with HXLPE than with less-crosslinked polyethylene inserts. One hundred seventy-one patients with a mean age of 58 ± 8 years (range, 35-59 years) received posterior cruciate-retaining prostheses with a less-crosslinked polyethylene tibial insert in one knee and a HXLPE tibial insert in the contralateral knee. From January 2007 to January 2010, we performed 366 same-day bilateral simultaneous sequential posterior cruciate-retaining TKAs in 183 patients, of whom 171 (93%) participated in this study. All patients during this study period underwent posterior cruciate-retaining TKAs regardless of deformity of the knees and we did not perform posterior-stabilized TKAs during the same period. Patients who had bilateral end-stage osteoarthritis and were younger than 60 years were selected for inclusion. Six patients (4%) were lost to followup before 5 years. Twenty-six patients were males and 145 were females. The mean duration of followup was 6 years (range, 5-8 years). At each followup, patients were assessed for loosening of the components, fracture or failure of the locking mechanism of the polyethylene inserts, or osteolysis. The survival rate of the knee prosthesis at a mean of 5.8 years after surgery was 100% (95% CI, 0.95-1.00) in both groups for the endpoint aseptic loosening and 99.4% (95% CI, 0.95-1.00) in both groups for the endpoint revision. No knee in either group had fracture or failure of the locking mechanism of the tibial polyethylene insert, and none had osteolysis. With the numbers available, we found no clinically important differences between HXLPE and less-crosslinked polyethylene inserts in posterior cruciate-retaining TKAs. Given that HXLPE is newer, as-yet unproven, and more expensive than the proven technology (less-crosslinked polyethylene), we suggest not adopting HXLPE for clinical use until it shows superiority. Level I, therapeutic study.

  3. Continuous spinal anesthesia for lower limb surgery: a retrospective analysis of 1212 cases

    PubMed Central

    Lux, Eberhard Albert

    2012-01-01

    Background Continuous spinal anesthesia is a very reliable and versatile technique for providing effective anesthesia and analgesia. However, the incidence of possible complications, including postdural puncture headache or neurological impairment, remains controversial. Therefore, the aim of the present retrospective study was to analyze a large number of patients for the incidence of adverse events after continuous spinal anesthesia with a microcatheter. Methods This retrospective study was conducted on 1212 patients who underwent surgery of the lower extremities with continuous spinal anesthesia, which was administered with 22-gauge Quincke spinal needles and 28-gauge microcatheters. Sociodemographic and clinical data were available from the patient records, and data on headaches and patient satisfaction were drawn from a brief postoperative patient questionnaire. Results The patient population included 825 females (68%) and 387 males; the median age was 61 (56–76). The types of operations performed were 843 hip prostheses, 264 knee prostheses, and 105 other leg operations. No major complications were observed in any of these patients. Tension headaches were experienced by 190 (15.7%) patients, but postdural puncture headaches were reported by only 18 (1.5%) patients. Nearly all patients (98.4%) were satisfied with continuous spinal anesthesia and confirmed that they would choose this kind of anesthesia again. Conclusion Based on the findings of this large data analysis, continuous spinal anesthesia using a 28-gauge microcatheter appears to be a safe and appropriate anesthetic technique in lower leg surgery for aged patients. PMID:23204868

  4. Sprint Start Kinetics of Amputee and Non-Amputee Sprinters

    PubMed Central

    Willwacher, Steffen; Herrmann, Volker; Heinrich, Kai; Funken, Johannes; Strutzenberger, Gerda; Goldmann, Jan-Peter; Braunstein, Björn; Brazil, Adam; Irwin, Gareth; Potthast, Wolfgang; Brüggemann, Gert-Peter

    2016-01-01

    The purpose of this study was to explore the relationship between the forces applied to the starting blocks and the start performances (SPs) of amputee sprinters (ASs) and non-amputee sprinters (NASs). SPs of 154 male and female NASs (100-m personal records [PRs], 9.58–14.00 s) and 7 male ASs (3 unilateral above knee, 3 unilateral below knee, 1 bilateral below knee; 100 m PRs, 11.70–12.70 s) with running specific prostheses (RSPs) were analysed during full-effort sprint starts using instrumented starting blocks that measured the applied forces in 3D. Using the NAS dataset and a combination of factor analysis and multiple regression techniques, we explored the relationship between force characteristics and SP (quantified by normalized average horizontal block power). Start kinetics were subsequently compared between ASs and NASs who were matched based on their absolute 100 m PR and their 100 m PR relative to the world record in their starting class. In NASs, 86% of the variance in SP was shared with five latent factors on which measured parameters related to force application to the rear and front blocks and the respective push-off directions in the sagittal plane of motion were loaded. Mediolateral force application had little influence on SP. The SP of ASs was significantly reduced compared to that of NASs matched on the basis of relative 100-m PR (−33.8%; d = 2.11, p < 0.001), while a non-significant performance reduction was observed when absolute 100-m PRs were used (−17.7%; d = 0.79, p = 0.09). These results are at least partially explained by the fact that force application to the rear block was clearly impaired in the affected legs of ASs. PMID:27846241

  5. Sprint Start Kinetics of Amputee and Non-Amputee Sprinters.

    PubMed

    Willwacher, Steffen; Herrmann, Volker; Heinrich, Kai; Funken, Johannes; Strutzenberger, Gerda; Goldmann, Jan-Peter; Braunstein, Björn; Brazil, Adam; Irwin, Gareth; Potthast, Wolfgang; Brüggemann, Gert-Peter

    2016-01-01

    The purpose of this study was to explore the relationship between the forces applied to the starting blocks and the start performances (SPs) of amputee sprinters (ASs) and non-amputee sprinters (NASs). SPs of 154 male and female NASs (100-m personal records [PRs], 9.58-14.00 s) and 7 male ASs (3 unilateral above knee, 3 unilateral below knee, 1 bilateral below knee; 100 m PRs, 11.70-12.70 s) with running specific prostheses (RSPs) were analysed during full-effort sprint starts using instrumented starting blocks that measured the applied forces in 3D. Using the NAS dataset and a combination of factor analysis and multiple regression techniques, we explored the relationship between force characteristics and SP (quantified by normalized average horizontal block power). Start kinetics were subsequently compared between ASs and NASs who were matched based on their absolute 100 m PR and their 100 m PR relative to the world record in their starting class. In NASs, 86% of the variance in SP was shared with five latent factors on which measured parameters related to force application to the rear and front blocks and the respective push-off directions in the sagittal plane of motion were loaded. Mediolateral force application had little influence on SP. The SP of ASs was significantly reduced compared to that of NASs matched on the basis of relative 100-m PR (-33.8%; d = 2.11, p < 0.001), while a non-significant performance reduction was observed when absolute 100-m PRs were used (-17.7%; d = 0.79, p = 0.09). These results are at least partially explained by the fact that force application to the rear block was clearly impaired in the affected legs of ASs.

  6. Neuroprostheses to treat neurogenic bladder dysfunction: current status and future perspectives.

    PubMed

    Rijkhoff, Nico J M

    2004-02-01

    Neural prostheses are a technology that uses electrical activation of the nervous system to restore function to individuals with neurological or sensory impairment. This article provides an introduction to neural prostheses and lists the most successful neural prostheses (in terms of implanted devices). The article then focuses on neurogenic bladder dysfunction and describes two clinically available implantable neural prostheses for treatment of neurogenic bladder dysfunction. Special attention is given to the usage of these neural prostheses in children. Finally, three new developments that may lead to a new generation of implantable neural prostheses for bladder control are described. They may improve the neural prostheses currently available and expand further the population of patients who can benefit from a neural prosthesis.

  7. Analysis of the times involved in processing and communication in a lower limb simulation system controlled by SEMG

    NASA Astrophysics Data System (ADS)

    Profumieri, A.; Bonell, C.; Catalfamo, P.; Cherniz, A.

    2016-04-01

    Virtual reality has been proposed for different applications, including the evaluation of new control strategies and training protocols for upper limb prostheses and for the study of new rehabilitation programs. In this study, a lower limb simulation environment commanded by surface electromyography signals is evaluated. The time delays generated by the acquisition and processing stages for the signals that would command the knee joint, were measured and different acquisition windows were analysed. The subjective perception of the quality of simulation was also evaluated when extra delays were added to the process. The results showed that the acquisition window is responsible for the longest delay. Also, the basic implemented processes allowed for the acquisition of three signal channels for commanding the simulation. Finally, the communication between different applications is arguably efficient, although it depends on the amount of data to be sent.

  8. Longitudinal research on the oral environment of elderly wearing fixed or removable prostheses.

    PubMed

    Tanaka, Junko; Tanaka, Masahiro; Kawazoe, Takayoshi

    2009-04-01

    The purpose of this study was to investigate oral environmental risk factors involved in caries incidence in the elderly. We investigated the relationship between the oral environment factors of the elderly with both fixed prostheses and removable prostheses at baseline and at follow-up and examined time-course changes of each oral environmental factor by prosthesis type. The subject group consisted 11 elderly patients with fixed prostheses and 11 who wore removable prostheses. We examined oral environmental factors by saliva tests. Five oral environmental factors were examined: the stimulated salivary flow rate, buffering capacity, and the counts of mutans streptococci (SM), lactobacilli (LB), and Candida (CA). We compared these factors for subjects with fixed prostheses and those wearing removable prostheses at baseline and at follow-up. Furthermore, 3-year changes in the factors of each oral environment were compared and evaluated. Significant differences were observed between the two groups in the salivary microbial counts of SM and LB at baseline and at follow-up. The LB counts increased in the Denture group during the 3-year period and significant differences were noted. We found that fixed prostheses are less cariogenic, and removable prostheses cause an increase in the cariogenic bacterial count. Regarding time-course changes by the type of prosthesis, the LB count tended to increase in the subjects with removable prostheses. The risk of caries due to a fixed prosthesis may be lower than that of removable prostheses.

  9. a Review of Retinal Prosthesis Approaches

    NASA Astrophysics Data System (ADS)

    Kien, Tran Trung; Maul, Tomas; Bargiela, Andrzej

    Age-related macular degeneration and retinitis pigmentosa are two of the most common diseases that cause degeneration in the outer retina, which can lead to several visual impairments up to blindness. Vision restoration is an important goal for which several different research approaches are currently being pursued. We are concerned with restoration via retinal prosthetic devices. Prostheses can be implemented intraocularly and extraocularly, which leads to different categories of devices. Cortical Prostheses and Optic Nerve Prostheses are examples of extraocular solutions while Epiretinal Prostheses and Subretinal Prostheses are examples of intraocular solutions. Some of the prostheses that are successfully implanted and tested in animals as well as humans can restore basic visual functions but still have limitations. This paper will give an overview of the current state of art of Retinal Prostheses and compare the advantages and limitations of each type. The purpose of this review is thus to summarize the current technologies and approaches used in developing Retinal Prostheses and therefore to lay a foundation for future designs and research directions.

  10. Improved accuracy of component alignment with the implementation of image-free navigation in total knee arthroplasty.

    PubMed

    Rosenberger, Ralf E; Hoser, Christian; Quirbach, Sebastian; Attal, Rene; Hennerbichler, Alfred; Fink, Christian

    2008-03-01

    Accuracy of implant positioning and reconstruction of the mechanical leg axis are major requirements for achieving good long-term results in total knee arthroplasty (TKA). The purpose of the present study was to determine whether image-free computer navigation technology has the potential to improve the accuracy of component alignment in TKA cohorts of experienced surgeons immediately and constantly. One hundred patients with primary arthritis of the knee underwent the unilateral total knee arthroplasty. The cohort of 50 TKAs implanted with conventional instrumentation was directly followed by the cohort of the very first 50 computer-assisted TKAs. All surgeries were performed by two senior surgeons. All patients received the Zimmer NexGen total knee prosthesis (Zimmer Inc., Warsaw, IN, USA). There was no variability regarding surgeons or surgical technique, except for the use of the navigation system (StealthStation) Treon plus Medtronic Inc., Minnesota, MI, USA). Accuracy of implant positioning was measured on postoperative long-leg standing radiographs and standard lateral X-rays with regard to the valgus angle and the coronal and sagittal component angles. In addition, preoperative deformities of the mechanical leg axis, tourniquet time, age, and gender were correlated. Statistical analyses were performed using the SPSS 15.0 (SPSS Inc., Chicago, IL, USA) software package. Independent t-tests were used, with significance set at P < 0.05 (two-tailed) to compare differences in mean angular values and frontal mechanical alignment between the two cohorts. To compute the rate of optimally implanted prostheses between the two groups we used the chi(2) test. The average postoperative radiological frontal mechanical alignment was 1.88 degrees of varus (range 6.1 degrees of valgus-10.1 degrees of varus; SD 3.68 degrees ) in the conventional cohort and 0.28 degrees of varus (range 3.7 degrees -6.0 degrees of varus; SD 1.97 degrees ) in the navigated cohort. Including all criteria for optimal implant alignment, 16 cases (32%) in the conventional cohort and 31 cases (62%) in the navigated cohort have been implanted optimally. The average difference in tourniquet time was modest with additional 12.9 min in the navigated cohort compared to the conventional cohort. Our findings suggest that the experienced knee surgeons can improve immediately and constantly the accuracy of component orientation using an image-free computer-assisted navigation system in TKA. The computer-assisted technology has shown to be easy to use, safe, and efficient in routine knee replacement surgery. We believe that navigation is a key technology for various current and future surgical alignment topics and minimal-invasive lower limb surgery.

  11. Ultrasonographic assessment of the quadriceps muscle and femoral cartilage in transtibial amputees using different prostheses.

    PubMed

    Şahin Onat, Şule; Malas, Fevziye Ünsal; Öztürk, Gökhan Tuna; Akkaya, Nuray; Kara, Murat; Özçakar, Levent

    2016-08-01

    In patients with lower limb amputations, gait alteration, increased loading on the intact extremity, and use of prosthesis may lead to joint degeneration. To explore the effects of prosthesis type on quadriceps muscle and distal femoral cartilage thicknesses in transtibial amputees. A cross-sectional study. A total of 38 below-knee amputees were enrolled in the study, of which 13 patients were using vacuum system type prosthesis and 25 patients were using silicon liner pin system prosthesis. Patients' femoral cartilage and quadriceps muscle thickness measurements were performed using musculoskeletal ultrasound. When compared with the intact sides, cartilage and rectus femoris, vastus intermedius, and vastus medialis muscle thickness values were significantly decreased on the amputee sides (all p < 0.05). Clinical characteristics and ultrasound measurements were similar between the two groups except the lateral and medial femoral condyle thicknesses, thinner in the silicon liner pin system users (both p < 0.05). The distal femoral cartilage and quadriceps muscle thicknesses were found to be decreased on the amputated sides, and the negative impact on the cartilage seemed to be worse in the silicon liner pin system users. This study might provide another argument as regards the preference of vacuum system type prosthesis to prevent possible knee osteoarthritis due to cartilage thinning in adult transtibial amputees. © The International Society for Prosthetics and Orthotics 2015.

  12. Evaluation of a Prototype Hybrid Vacuum Pump to Provide Vacuum-Assisted Suspension for Above-Knee Prostheses

    PubMed Central

    Major, Matthew J.; Caldwell, Ryan; Fatone, Stefania

    2015-01-01

    Vacuum-assisted suspension (VAS) of prosthetic sockets utilizes a pump to evacuate air from between the prosthetic liner and socket, and are available as mechanical or electric systems. This technical note describes a hybrid pump that benefits from the advantages of mechanical and electric systems, and evaluates a prototype as proof-of-concept. Cyclical bench testing of the hybrid pump mechanical system was performed using a materials testing system to assess the relationship between compression cycles and vacuum pressure. Phase 1 in vivo testing of the hybrid pump was performed by an able-bodied individual using prosthesis simulator boots walking on a treadmill, and phase 2 involved an above-knee prosthesis user walking with the hybrid pump and a commercial electric pump for comparison. Bench testing of 300 compression cycles produced a maximum vacuum of 24 in-Hg. In vivo testing demonstrated that the hybrid pump continued to pull vacuum during walking, and as opposed to the commercial electric pump, did not require reactivation of the electric system during phase 2 testing. The novelty of the hybrid pump is that while the electric system provides rapid, initial vacuum suspension, the mechanical system provides continuous air evacuation while walking to maintain suspension without reactivation of the electric system, thereby allowing battery power to be reserved for monitoring vacuum levels. PMID:27462383

  13. Which primary total knee replacement? A review of currently available TKR in the United Kingdom.

    PubMed Central

    Liow, R. Y.; Murray, D. W.

    1997-01-01

    Comparative information on total knee replacements (TKRs) is not readily available. With the help of implant manufacturers and distributors, we have compiled a list of TKRs on the market in the UK and summarised the information about these implants in a table. There are 37 different TKRs, marketed by 14 companies; 54% have been introduced since 1990. The number of different implants is increasing. At least eight designs have undergone major modifications, while many have had minor alterations. Of the TKRs on the market, 60% are modular. Some 54% of TKRs have no published results in peer-reviewed journals; only one of the four most widely used prostheses has published survival figures. New and modified implants are introduced without clinical evidence of their superiority over other available designs. Published results in peer-reviewed journals are currently the best evidence available on the reliability of an implant. When selecting an implant, surgeons should be aware if the prosthesis has any such results, the length of the follow-up, and the survival rates that are achieved. More detailed interpretation is difficult because of the different combinations used in modular implants and because of the frequent modification of existing designs. Properly conducted long-term clinical trials should be encouraged as they are the only means of evaluating new designs. PMID:9326124

  14. Within-subject comparisons of implant-supported mandibular prostheses: psychometric evaluation.

    PubMed

    de Grandmont, P; Feine, J S; Taché, R; Boudrias, P; Donohue, W B; Tanguay, R; Lund, J P

    1994-05-01

    In a within-subject cross-over clinical trial, psychometric and functional measurements were taken while 15 completely edentulous subjects wore mandibular fixed prostheses and long-bar removable implant-supported prostheses. In this paper, the results of a psychometric assessment are presented. Eight subjects first received the fixed bridge and seven the removable type. After having worn a prosthesis for a minimum of two months, subjects responded to psychometric scales that measured their perceptions of various factors associated with prostheses. They also chewed test foods while masticatory activity was recorded. The prostheses were then changed and the procedures repeated. At the end of the study, patients were asked to choose the prosthesis that they wished to keep. Patients assigned significantly higher scores, on visual analogue scales, to both types of implant-supported prostheses than to their original conventional prostheses for all factors tested, including general satisfaction. However, no statistically significant differences between the two implant-supported prostheses were detected except for the difficulty of chewing carrot, apple, and sausage. For these foods, the fixed prostheses were rated higher. Subjects' responses to category scales were consistent with their responses to the visual analogue scales. These results suggest that, although patients find the fixed bridge to be significantly better for chewing harder foods, there is no difference in their general satisfaction with the two types of prostheses.

  15. Biomechanical evaluation of two types of short-stemmed hip prostheses compared to the trust plate prosthesis by three-dimensional measurement of micromotions.

    PubMed

    Fottner, Andreas; Schmid, Markus; Birkenmaier, Christof; Mazoochian, Farhad; Plitz, Wolfgang; Volkmar, Jansson

    2009-06-01

    Stemless and short-stemmed hip prostheses have been developed to preserve femoral bone stock. While all these prostheses claim a more or less physiological load transfer, clinical long-term results are only available for the stemless thrust plate prosthesis. In this study, the in vitro primary stability of the thrust plate prosthesis was compared to two types of short-stemmed prostheses. In addition to the well-established Mayo prosthesis, the modular Metha prosthesis was tested using cone adapters with 130 degrees and 140 degrees neck-shaft-angles. The prostheses were implanted in composite femurs and loaded dynamically (300-1700 N). Three-dimensional micromotions at the bone-prosthesis interface were measured. In addition, the three-dimensional deformations at the surface of the composite femur were measured to gain data on the strain distribution. For all tested prostheses, the micromotions did not exceed 150 microm, the critical value for osteointegration. The thrust plate prosthesis revealed similar motions as the short-stemmed prostheses. The short-stemmed prosthesis with the 130 degrees cone tended to have the highest micromotions of all tested short-stemmed prostheses. The thrust plate prosthesis revealed the lowest alteration of bone surface deformation after implantation. The comparably low micromotions of the thrust plate prosthesis and the short-stemmed prostheses should be conducive to osseous integration. The higher alteration of load transmission after implantation reveals a higher risk of stress shielding for the short-stemmed prostheses.

  16. The effect of adhesive strength of hydroxyapatite coating on the stability of hydroxyapatite-coated prostheses in vivo at the early stage of implantation

    PubMed Central

    Duan, Yonghong; Zhu, Shu; Guo, Fei; Zhu, Jinyu; Li, Mao; Ma, Jie

    2012-01-01

    Introduction With the increase in joint revision surgery after arthroplasty, defects of hydroxyapatite (HA)-coated prostheses have been observed increasingly often. These defects adversely affect the prosthetic stability in vivo. This study has analyzed the potential effect of the adhesive strength of HA coating on the stability of HA-coated prostheses in vivo after its implantation. Material and methods Sixty experimental rabbits were divided into HA- and Ti-coated groups. HA-coated prostheses were implanted into the bilateral epicondyle of rabbits femurs. Ti-coated prostheses were implanted as control. At different time points(4, 9, and 15 weeks) after implantation, bone tissue samples were fetched out respectively for histomorphometric analysis. Push-out testing was used to detect the ultimate shear strength at the bone-prosthesis interface. Scanning electron microscope (SEM) observation and energy-dispersive X-ray spectroscopy (EDX) analysis were used to observe the changes in surface composition of the prostheses after the ultimate shear strength testing. The coating adhesive strength of two kinds of coatings were also examined by scratch testing. Results Hydroxyapatite coating has an obvious advantage in facilitating osteogenesis and its plays a critical role in the stability of prostheses. However, the ultimate shear strength of HA-coated prostheses is much lower than that of Ti-coated implants (p < 0.01). Further study has demonstrated that the stability of HA-coated prostheses in vivo is affected by the relatively low adhesive strength between coating and substrate. Conclusions Obvious advantage in facilitating osteogenesis around HA-coated prostheses is not the only factor that determines the stability of prostheses in vivo. PMID:22661990

  17. Development, implementation and evaluation of a dedicated metal artefact reduction method for interventional flat-detector CT.

    PubMed

    Prell, D; Kalender, W A; Kyriakou, Y

    2010-12-01

    The purpose of this study was to develop, implement and evaluate a dedicated metal artefact reduction (MAR) method for flat-detector CT (FDCT). The algorithm uses the multidimensional raw data space to calculate surrogate attenuation values for the original metal traces in the raw data domain. The metal traces are detected automatically by a three-dimensional, threshold-based segmentation algorithm in an initial reconstructed image volume, based on twofold histogram information for calculating appropriate metal thresholds. These thresholds are combined with constrained morphological operations in the projection domain. A subsequent reconstruction of the modified raw data yields an artefact-reduced image volume that is further processed by a combining procedure that reinserts the missing metal information. For image quality assessment, measurements on semi-anthropomorphic phantoms containing metallic inserts were evaluated in terms of CT value accuracy, image noise and spatial resolution before and after correction. Measurements of the same phantoms without prostheses were used as ground truth for comparison. Cadaver measurements were performed on complex and realistic cases and to determine the influences of our correction method on the tissue surrounding the prostheses. The results showed a significant reduction of metal-induced streak artefacts (CT value differences were reduced to below 22 HU and image noise reduction of up to 200%). The cadaver measurements showed excellent results for imaging areas close to the implant and exceptional artefact suppression in these areas. Furthermore, measurements in the knee and spine regions confirmed the superiority of our method to standard one-dimensional, linear interpolation.

  18. Outcome of Surgical Fixation of Lateral Column Distal Humerus Fractures.

    PubMed

    Von Keudell, Arvind; Kachooei, Amir R; Moradi, Ali; Jupiter, Jesse B

    2016-05-01

    The purpose of this study was to report the long-term outcome and complications of surgically fixated lateral unicondylar distal humerus fractures. Retrospective Review. Two level 1 Trauma Centers, Massachusetts General Hospital and Brigham and Women's Hospital. Between 2002 and 2014, 24 patients treated with open reduction and internal fixation for lateral unicondylar distal humerus fractures (OTA/AO type B1 fractures) were retrospectively reviewed. Open reduction and internal fixation. Union rates, early complications, functional outcome, and the range of elbow motion were evaluated. Disabilities of the arm, shoulder, and hand, Mayo elbow Performance Index, satisfaction, pain scale, and American Shoulder and Elbow Surgeons. The mean age of patients was 46 ± 23 years at the time of surgery. The average final flexion/extension arc of motion was 108°. Reoperations were performed in 9 of 24 elbows after an average 21 ± 31 months. Twenty of the 24 patients were available for the clinical follow-up at an average of 70 months (range: 16-144 months). Disabilities of the arm, shoulder, and hand averaged at 10.8 ± 11.7 points, satisfaction at 9.5 ± 1.2, American Shoulder and Elbow Surgeons score at 88.5 ± 13.3 points at final follow-up. Based on the functional classification proposed by Jupiter, 16 demonstrated good to excellent results, 2 fair and 2 poor result. Outcome of open reduction and internal fixation of isolated lateral column distal humerus fractures can result in high union rates with acceptable outcome scores and high patient satisfaction despite a high reoperation rate. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  19. [Time course of microbial colonization of different voice prostheses].

    PubMed

    Schuldt, T; Dommerich, S; Pau, H-W; Kramp, B

    2010-10-01

    For the vocal rehabilitation of laryngectomized patients, voice prostheses are actually one of the best known methods. Caused by the surface colonisation with bacteria and fungi the life time of the prostheses is limited to 3-4 months. In a time period of 127 months we analysed the surface colonisation of 118 voice prostheses. The mean life time of the prostheses was 156 days. In reference to the prosthesis model we also recorded different times of usage (ESKA-Herrmann 141, Provox 2 184 and Provox 1 204 days (p>0.05)). In the microbiological examination the dominating bacteria were S. aureus, Klebsiella sp. and Proteus sp. It was possible to cultivate all these bacteria on every type of prosthesis used in the study. In addition C. albicans, C. glabrata, C. krusei and C. tropicalis were the main fungi on the silicone surface. Thereby a more frequent colonisation with C. krusei on ESKA-Herrmann prostheses was measured, caused by the bigger contact area with saliva on this model (p=0.034). Because of the similar position and way of function, all types of voice prostheses are colonized by almost the same species of bacteria and fungi. But in dependency of the type an affinity of individual species to special prostheses exist. The knowledge of these individual affinities is necessary for the further development of voice prostheses. Furthermore the diversity of bacteria and fungi species showed a level of saturation on the surface. This is caused by the limited space on the silicone prostheses. © Georg Thieme Verlag KG Stuttgart · New York.

  20. Mechanical characterization and comparison of energy storage and return prostheses.

    PubMed

    Rigney, Stacey M; Simmons, Anne; Kark, Lauren

    2017-03-01

    The suitability of finite element analysis (FEA) for standardizing the mechanical characterization of energy storage and return (ESAR) prostheses was investigated. A methodology consisting of both experimental and numerical analysis was proposed and trialed for the Vari-flex ® Modular TM , Flex-foot Cheetah and Cheetah Xtreme by Össur ® and a 1E90 Sprinter by Ottobock ® . Gait analysis was conducted to determine suitable orientation angles for non-destructive testing (NDT) of the ESAR prostheses followed by a quasi-static inverse FEA procedure within COMSOL Multiphysics ® , where the NDT conditions were replicated to determine the homogenized material properties of the prostheses. The prostheses' loading response under bodyweight for an 80kg person was then simulated, using both Eigenfrequency and time-dependent analysis. The apparent stiffness under bodyweight was determined to be 94.7, 48.6, 57.4 and 65.0Nmm -1 for the Vari-flex ® Modular TM , Flex-foot Cheetah, Cheetah Xtreme and 1E90 Sprinter, respectively. Both the energy stored and returned by the prostheses varied negatively with stiffness, yet the overall efficiency of the prostheses were similar, at 52.7, 52.0, 51.7 and 52.4% for the abovementioned prostheses. The proposed methodology allows the standardized assessment and comparison of ESAR prostheses without the confounding influences of subject-specific gait characteristics. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  1. [Long-term observation of 920 porcelain fused to metal prostheses].

    PubMed

    Jiang, Yong-Lin; Sun, Jian; Weng, Wei-Min; Zhang, Fu-Qiang

    2006-10-01

    To evaluate the long-term clinical results of porcelain fused to metal prostheses. Since January 1995, 920 porcelain fused to metal prostheses were fabricated. The long-term outcome were evaluated according to the condition of the prosthese, abutment and the periodontal tissue in the respects of successful rate and causes of failure. 74 patients were found to be during the follow up period, including 36 anterior crowns (46 units), 18 posterior crowns (22 units), 12 percentage of anterior bridges and 8 posterior bridges. The overall failure rate was 8.04%, 4.84% for crown, 8.77% for bridge. The failed prostheses was 5.39%. Porcelain fused to metal prostheses is an ideal method for restoration. The standard process both for the clinician and the technician must be obeyed to improve the success rate.

  2. Combined tooth-implant-supported telescopic prostheses in a midterm follow-up of > 2 years.

    PubMed

    Joda, Tim

    2013-01-01

    The aim of this trial was to evaluate telescopic-retained prostheses on teeth and implants. Ten patients with a mean of 2.8 teeth received strategic implants to achieve triangular/quadrangular support. Survival and complication rates were estimated for telescopic abutments and prostheses. After a mean observation period of > 2 years, no abutment was lost and all prostheses were in function. Complication rates were low, and maintenance services were limited to minor interventions. Combined tooth-implant-retained telescopic prostheses improve prosthetic support and offer successful function over a midterm period in patients with a severely reduced dentition.

  3. [Application of negative molds technology based on three-dimensional printing in digital maxillofacial prostheses].

    PubMed

    Gu, X Y; Chen, X B; Jiao, T; Zhang, F Q; Jiang, X Q

    2017-06-09

    Objective: To explore a digital negative molds technique based on three-dimensional (3D) printing to assist in the manufacture of maxillofacial prostheses, and to improve the deficiency of the current clinical treatment. Methods: Seventeen patients with maxillofacial defects (including nasal defects, orbital defects, cheek defects, auricle defect) were scanned by means of facial optical scanning and computer tomography (CT). The 3D models were then reconstructed and global registration was made to merge the reconstructed models into a new digital model for 3D design. The 3D design of the prostheses was implemented in software. The mechanical connection structure was designed by forward engineering technology for 3 patients with intra-oral defects in maxilla who needed to make removable partial dentures, so that the silicone prostheses and removable partial denture could be combined. The removable partial dentures were made by conventional method and connected with the prostheses. According to the 3D data of the prostheses, the digital negative molds were designed, and the 3D printing technology was used to finish the processing of the resin molds. Silicone for prostheses were filled and cured in the resin molds to fabricate the clinical restorations for the patients. The margin adaptation and retention of the prostheses was detected. Results: Twenty patients with varying degrees of maxillofacial defects were rehabilitated using the courses developed in the study. All patients reported no pain or discomfort during the treatment; and they were satisfied with the final prostheses of the shape, color, retention, stability, etc. Eighteen of the prostheses showed good marginal adaptation, and sixteen of the prostheses showed good retention effect. Conclusions: The digital negative molds technique used in this study could greatly reduce the intensity of manual operation and provided a good therapeutic effect for patients with maxillofacial defects.

  4. Comparison of bone-anchored prostheses and socket prostheses for patients with a lower extremity amputation: a systematic review.

    PubMed

    Leijendekkers, Ruud A; van Hinte, Gerben; Frölke, Jan Paul; van de Meent, Hendrik; Nijhuis-van der Sanden, Maria W G; Staal, J Bart

    2017-06-01

    This study aimed to provide an overview of a) the used measurement instruments in studies evaluating effects on quality of life (QoL), function, activity and participation level in patients with a lower extremity amputation using bone-anchored prostheses compared to socket prostheses and b) the effects themselves. A systematic literature search was conducted in MEDLINE, Cochrane, EMBASE, CINAHL and Web of Science. Included studies compared QoL, function, activity and/or participation level in patients with bone-anchored or socket prostheses. A best-evidence synthesis was performed. Out of 226 studies, five cohort and two cross-sectional studies were eligible for inclusion, all had methodological shortcomings. These studies used 10 different measurement instruments and two separate questions to assess outcome. Bone-anchored prostheses were associated with better condition-specific QoL and better outcomes on several of the physical QoL subscales, outcomes on the physical bodily pain subscale were inconclusive. Outcomes on function and activity level increased, no change was found at participation level. The level of evidence was limited. There is a need for a standard set of instruments. There was limited evidence that bone-anchored prostheses resulted in higher QoL, function and activity levels than socket prostheses, in patients with socket-related problems. Implications for Rehabilitation Use of bone-anchored prostheses in combination with intensive outpatient rehabilitation may improve QoL, function and activity level compared with socket prosthesis use in patients with a transfemoral amputation and socket-related problems. All clinicians and researchers involved with bone-anchored prostheses should use and publish data on QoL, function, activity and participation level. There needs to be an agreement on a standard set of instruments so that interventions for patients with a lower extremity amputation are assessed consistently.

  5. [Evolution of the number and type of penile prostheses implanted in France for erectile dysfunction: Analysis of French national coding database (2006-2013)].

    PubMed

    Lipsker, A; Saljoghi, R; Lecuelle, D; Caillet, K; Alezra, E; Le Roux, F; Demailly, M; Saint, F

    2016-09-01

    Patients who are not responding to injectable and/or vacuum oral pharmacological treatments can receive a penile prosthesis. Three types of penile prostheses are used in France: rigid, semi-rigid and inflatable prostheses 3-piece or 2-piece. We have assessed the National surgical insertion practices between 2006 and 2013 (number of prostheses insertions, types, procedure locations, number of surgeons and distribution [public or private sectors]). Data analysis from the French Technical Agency of Information on Hospitals (ATIH) (2006-2013) using the common classification of medical acts (CCAM) and after code extractions related to this surgery (JHLA002, JHLA003, JHLA004). Between 2006 and 2013, the number of penile implants in France doubled (307 to 633), inflatable penile prostheses with an extracavernous component remained the most frequently used (87 %) (228 to 552) (+142 %). The use of semi-rigid prostheses declined by 26.7 %. The distribution between the private and public sector was close to 1 in 2013. More than half of French penile prostheses were implanted in three regions (Île-de-France, Languedoc-Roussillon, Rhône-Alpes). Nearly 62 % of surgeons implanted only one or two three-compartment prostheses in 2013. The number of penile prostheses in France doubled between 2006 and 2013. Three regions were particularly active as far as this surgery is concerned (Île-de-France, Languedoc-Roussillon, Rhône-Alpes). They were boosted by 5 surgeons with more than 20 prostheses surgeries a year. 4. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  6. Dual jaw treatment of edentulism using implant-supported monolithic zirconia fixed prostheses.

    PubMed

    Altarawneh, Sandra; Limmer, Bryan; Reside, Glenn J; Cooper, Lyndon

    2015-01-01

    This case report describes restoration of the edentulous maxilla and mandible with implant supported fixed prostheses using monolithic zirconia, where the incisal edges and occluding surfaces were made of monolithic zirconia. Edentulism is a debilitating condition that can be treated with either a removable or fixed dental prosthesis. The most common type of implant-supported fixed prosthesis is the metal acrylic (hybrid), with ceramo-metal prostheses being used less commonly in complete edentulism. However, both of these prostheses designs are associated with reported complications of screw loosening or fracture and chipping of acrylic resin and porcelain. Monolithic zirconia implant-supported fixed prostheses have the potential for reduction of such complications. In this case, the CAD/CAM concept was utilized in fabrication of maxillary and mandibular screw-retained implant-supported fixed prostheses using monolithic zirconia. Proper treatment planning and execution coupled with utilizing advanced technologies contributes to highly esthetic results. However, long-term studies are required to guarantee a satisfactory long-term outcome of this modality of treatment. This case report describes the clinical and technical procedures involved in fabrication of maxillary and mandibular implant-supported fixed prostheses using monolithic zirconia as a treatment of edentulism, and proposes the possible advantages associated with using monolithic zirconia in eliminating dissimilar interfaces in such prostheses that are accountable for the most commonly occurring technical complication for these prostheses being chipping and fracture of the veneering material. © 2015 Wiley Periodicals, Inc.

  7. Gender differences in the anatomy of the distal femur.

    PubMed

    Gillespie, R J; Levine, A; Fitzgerald, S J; Kolaczko, J; DeMaio, M; Marcus, R E; Cooperman, D R

    2011-03-01

    Recently, gender-specific designs of total knee replacement have been developed to accommodate anatomical differences between males and females. We examined a group of male and female distal femora matched for age and height, to determine if there was a difference in the aspect ratio (mediolateral distance versus anteroposterior distance) and the height of the anterior flange between the genders. The Hamann-Todd Collection provided 1207 skeletally mature cadaver femora. The femoral length, the anteroposterior height, height of the lateral and medial flanges and the mediolateral width were measured in all the specimens. The mechanical axis of the femur, the cut articular width and the aspect ratio were assessed. Statistical analysis of the effect of gender upon the aspect ratio and the lateral and medial flanges was undertaken, controlling for age, height and race. The mean aspect ratio of male femora was 1.21 (SD 0.07) and of female femora it was 1.16 (SD 0.06) (p < 0.001). There was no significant difference between male and female specimens in the mean size of the lateral flange (6.57 mm (SD 2.57) and 7.02 mm (SD 2.36), respectively; p = 0.099) or of the medial flange (3.03 mm (SD 2.47) and 3.56 mm (SD 2.32), respectively; p = 0.67). Future work in the design of knee prostheses should take into account the overall variability of the anatomy of the distal femur.

  8. Do modern total knee replacements offer better value for money? A health economic analysis.

    PubMed

    Hamilton, David F; Clement, Nicholas D; Burnett, Richard; Patton, James T; Moran, Mathew; Howie, Colin R; Simpson, A H R W; Gaston, Paul

    2013-11-01

    Cost effectiveness is an increasingly important factor in today's healthcare environment, and selection of arthroplasty implant is not exempt from such concerns. Quality adjusted life years (QALYs) are the typical tool for this type of evaluation. Using this methodology, joint arthroplasty has been shown to be cost effective; however, studies directly comparing differing prostheses are lacking. Data was gathered in a single-centre prospective double-blind randomised controlled trial comparing the outcome of modern and traditional knee implants, using the Short Form 6 dimensional (SF-6D) score and quality adjusted life year (QALY) methodology. There was significant improvement in the SF-6D score for both groups at one year (p < 0.0001). The calculated overall life expectancy for the study cohort was 15.1 years, resulting in an overall QALY gain of 2.144 (95% CI 1.752-2.507). The modern implant group demonstrated a small improvement in SF-6D score compared to the traditional design at one year (0.141 versus 0.143, p = 0.94). This difference resulted in the modern implant costing £298 less per QALY at one year. This study demonstrates that modern implant technology does not influence the cost-effectiveness of TKA using the SF-6D and QALY methodology. This type of analysis however assesses health status, and is not sensitive to joint specific function. Evolutionary design changes in implant technology are thus unlikely to influence QALY analysis following joint replacement, which has important implications for implant procurement.

  9. A randomised controlled trial of the clinical effectiveness and cost-effectiveness of different knee prostheses: the Knee Arthroplasty Trial (KAT).

    PubMed

    Murray, David W; MacLennan, Graeme S; Breeman, Suzanne; Dakin, Helen A; Johnston, Linda; Campbell, Marion K; Gray, Alastair M; Fiddian, Nick; Fitzpatrick, Ray; Morris, Richard W; Grant, Adrian M

    2014-03-01

    In the late 1990s, new developments in knee replacement were identified as a priority for research within the NHS. The newer forms of arthroplasty were more expensive and information was needed on their safety and cost-effectiveness. The Knee Arthroplasty Trial examined the clinical effectiveness and cost-effectiveness of four aspects of knee replacement surgery: patellar resurfacing, mobile bearings, all-polyethylene tibial components and unicompartmental replacement. This study comprised a partial factorial, pragmatic, multicentre randomised controlled trial with a trial-based cost-utility analysis which was conducted from the perspective of the NHS and the patients treated. Allocation was computer generated in a 1 : 1 ratio using a central system, stratified by eligible comparisons and surgeon, minimised by participant age, gender and site of disease. Surgeons were not blinded to allocated procedures. Participants were unblinded if they requested to know the prosthesis they received. The setting for the trial was UK secondary care. Patients were eligible for inclusion if a decision had been made for them to have primary knee replacement surgery. Patients were recruited to comparisons for which the surgeon was in equipoise about which type of operation was most suitable. Patients were randomised to receive a knee replacement with the following: patellar resurfacing or no patellar resurfacing irrespective of the design of the prosthesis used; a mobile bearing between the tibial and femoral components or a bearing fixed to the tibial component; a tibial component made of either only high-density polyethylene ('all polyethylene') or a polyethylene bearing fixed to a metal backing plate with attached stem; or unicompartmental or total knee replacement. The primary outcome was the Oxford Knee Score (OKS). Other outcomes were Short Form 12; EuroQol 5D; intraoperative and postoperative complications; additional surgery; cost; and cost-effectiveness. Patients were followed up for a median of 10 years; the economic evaluation took a 10-year time horizon, discounting costs and quality-adjusted life-years (QALYs) at 3.5% per annum. A total of 116 surgeons in 34 centres participated and 2352 participants were randomised: 1715 in patellar resurfacing; 539 in mobile bearing; 409 in all-polyethylene tibial component; and 34 in the unicompartmental comparisons. Of those randomised, 345 were randomised to two comparisons. We can be more than 95% confident that patellar resurfacing is cost-effective, despite there being no significant difference in clinical outcomes, because of increased QALYs [0.187; 95% confidence interval (CI) -0.025 to 0.399] and reduced costs (-£104; 95% CI -£630 to £423). We found no definite advantage or disadvantage of mobile bearings in OKS, quality of life, reoperation and revision rates or cost-effectiveness. We found improved functional results for metal-backed tibias: complication, reoperation and revision rates were similar. The metal-backed tibia was cost-effective (particularly in the elderly), costing £35 per QALY gained. The results provide evidence to support the routine resurfacing of the patella and the use of metal-backed tibial components even in the elderly. Further follow-up is required to assess the stability of these findings over time and to inform the decision between mobile and fixed bearings. Current Controlled Trials ISRCTN45837371. This project was funded by the NIHR Health Technology Assessment programme and the orthopaedic industry. It will be published in full in Health Technology Assessment; Vol. 18, No. 19. See the NIHR Journals Library website for further project information.

  10. Microbial biofilms on facial prostheses.

    PubMed

    Ariani, Nina; Vissink, Arjan; van Oort, Robert P; Kusdhany, Lindawati; Djais, Ariadna; Rahardjo, Tri Budi W; van der Mei, Henny C; Krom, Bastiaan P

    2012-01-01

    The composition of microbial biofilms on silicone rubber facial prostheses was investigated and compared with the microbial flora on healthy and prosthesis-covered skin. Scanning electron microscopy showed the presence of mixed bacterial and yeast biofilms on and deterioration of the surface of the prostheses. Microbial culturing confirmed the presence of yeasts and bacteria. Microbial colonization was significantly increased on prosthesis-covered skin compared to healthy skin. Candida spp. were exclusively isolated from prosthesis-covered skin and from prostheses. Biofilms from prostheses showed the least diverse band-profile in denaturing gradient gel electrophoresis (DGGE) whereas prosthesis-covered skin showed the most diverse band-profile. Bacterial diversity exceeded yeast diversity in all samples. It is concluded that occlusion of the skin by prostheses creates a favorable niche for opportunistic pathogens such as Candida spp. and Staphylococcus aureus. Biofilms on healthy skin, skin underneath the prosthesis and on the prosthesis had a comparable composition, but the numbers present differed according to the microorganism.

  11. Computer-aided dental prostheses construction using reverse engineering.

    PubMed

    Solaberrieta, E; Minguez, R; Barrenetxea, L; Sierra, E; Etxaniz, O

    2014-01-01

    The implementation of computer-aided design/computer-aided manufacturing (CAD/CAM) systems with virtual articulators, which take into account the kinematics, constitutes a breakthrough in the construction of customised dental prostheses. This paper presents a multidisciplinary protocol involving CAM techniques to produce dental prostheses. This protocol includes a step-by-step procedure using innovative reverse engineering technologies to transform completely virtual design processes into customised prostheses. A special emphasis is placed on a novel method that permits a virtual location of the models. The complete workflow includes the optical scanning of the patient, the use of reverse engineering software and, if necessary, the use of rapid prototyping to produce CAD temporary prostheses.

  12. Bi-articular Knee-Ankle-Foot Exoskeleton Produces Higher Metabolic Cost Reduction than Weight-Matched Mono-articular Exoskeleton.

    PubMed

    Malcolm, Philippe; Galle, Samuel; Derave, Wim; De Clercq, Dirk

    2018-01-01

    The bi-articular m. gastrocnemius and the mono-articular m. soleus have different and complementary functions during walking. Several groups are starting to use these biological functions as inspiration to design prostheses with bi-articular actuation components to replace the function of the m. gastrocnemius. Simulation studies indicate that a bi-articular configuration and spring that mimic the m. gastrocnemius could be beneficial for orthoses or exoskeletons. Our aim was to test the effect of a bi-articular and spring configuration that mimics the m. gastrocnemius and compare this to a no-spring and mono-articular configuration. We tested nine participants during walking with knee-ankle-foot exoskeletons with dorsally mounted pneumatic muscle actuators. In the bi-articular plus spring condition the pneumatic muscles were attached to the thigh segment with an elastic cord. In the bi-articular no-spring condition the pneumatic muscles were also attached to the thigh segment but with a non-elastic cord. In the mono-articular condition the pneumatic muscles were attached to the shank segment. We found the highest reduction in metabolic cost of 13% compared to walking with the exoskeleton powered-off in the bi-articular plus spring condition . Possible explanations for this could be that the exoskeleton delivered the highest total positive work in this condition at the ankle and the knee and provided more assistance during the isometric phase of the biological plantarflexors. As expected we found that the bi-articular conditions reduced m. gastrocnemius EMG more than the mono-articular condition but this difference was not significant. We did not find that the mono-articular condition reduces the m. soleus EMG more than the bi-articular conditions . Knowledge of specific effects of different exoskeleton configurations on metabolic cost and muscle activation could be useful for providing customized assistance for specific gait impairments.

  13. Bi-articular Knee-Ankle-Foot Exoskeleton Produces Higher Metabolic Cost Reduction than Weight-Matched Mono-articular Exoskeleton

    PubMed Central

    Malcolm, Philippe; Galle, Samuel; Derave, Wim; De Clercq, Dirk

    2018-01-01

    The bi-articular m. gastrocnemius and the mono-articular m. soleus have different and complementary functions during walking. Several groups are starting to use these biological functions as inspiration to design prostheses with bi-articular actuation components to replace the function of the m. gastrocnemius. Simulation studies indicate that a bi-articular configuration and spring that mimic the m. gastrocnemius could be beneficial for orthoses or exoskeletons. Our aim was to test the effect of a bi-articular and spring configuration that mimics the m. gastrocnemius and compare this to a no-spring and mono-articular configuration. We tested nine participants during walking with knee-ankle-foot exoskeletons with dorsally mounted pneumatic muscle actuators. In the bi-articular plus spring condition the pneumatic muscles were attached to the thigh segment with an elastic cord. In the bi-articular no-spring condition the pneumatic muscles were also attached to the thigh segment but with a non-elastic cord. In the mono-articular condition the pneumatic muscles were attached to the shank segment. We found the highest reduction in metabolic cost of 13% compared to walking with the exoskeleton powered-off in the bi-articular plus spring condition. Possible explanations for this could be that the exoskeleton delivered the highest total positive work in this condition at the ankle and the knee and provided more assistance during the isometric phase of the biological plantarflexors. As expected we found that the bi-articular conditions reduced m. gastrocnemius EMG more than the mono-articular condition but this difference was not significant. We did not find that the mono-articular condition reduces the m. soleus EMG more than the bi-articular conditions. Knowledge of specific effects of different exoskeleton configurations on metabolic cost and muscle activation could be useful for providing customized assistance for specific gait impairments. PMID:29551959

  14. Quantification of dental prostheses on cone‐beam CT images by the Taguchi method

    PubMed Central

    Kuo, Rong‐Fu; Fang, Kwang‐Ming; TY, Wong

    2016-01-01

    The gray values accuracy of dental cone‐beam computed tomography (CBCT) is affected by dental metal prostheses. The distortion of dental CBCT gray values could lead to inaccuracies of orthodontic and implant treatment. The aim of this study was to quantify the effect of scanning parameters and dental metal prostheses on the accuracy of dental cone‐beam computed tomography (CBCT) gray values using the Taguchi method. Eight dental model casts of an upper jaw including prostheses, and a ninth prosthesis‐free dental model cast, were scanned by two dental CBCT devices. The mean gray value of the selected circular regions of interest (ROIs) were measured using dental CBCT images of eight dental model casts and were compared with those measured from CBCT images of the prosthesis‐free dental model cast. For each image set, four consecutive slices of gingiva were selected. The seven factors (CBCTs, occlusal plane canting, implant connection, prosthesis position, coping material, coping thickness, and types of dental restoration) were used to evaluate scanning parameter and dental prostheses effects. Statistical methods of signal to noise ratio (S/N) and analysis of variance (ANOVA) with 95% confidence were applied to quantify the effects of scanning parameters and dental prostheses on dental CBCT gray values accuracy. For ROIs surrounding dental prostheses, the accuracy of CBCT gray values were affected primarily by implant connection (42%), followed by type of restoration (29%), prostheses position (19%), coping material (4%), and coping thickness (4%). For a single crown prosthesis (without support of implants) placed in dental model casts, gray value differences for ROIs 1–9 were below 12% and gray value differences for ROIs 13–18 away from prostheses were below 10%. We found the gray value differences set to be between 7% and 8% for regions next to a single implant‐supported titanium prosthesis, and between 46% and 59% for regions between double implant‐supported, nickel‐chromium alloys (Ni‐Cr) prostheses. Quantification of the effect of prostheses and scanning parameters on dental CBCT gray values was assessed. PACS numbers: 87.59.bd, 87.57Q PMID:26894354

  15. Single-Surgeon Experience and Complications of a Fixed-Bearing Total Ankle Arthroplasty.

    PubMed

    Pangrazzi, Garett J; Baker, Erin A; Shaheen, Phillip J; Okeagu, Chikezie N; Fortin, Paul T

    2018-01-01

    Total ankle arthroplasty (TAA) has historically resulted in inferior survivorship rates compared with total hip and knee arthroplasty, because of technical issues unique to ankle anatomy. In this study, a single-surgeon series of intra- and postoperative complications as well as resultant reoperations/revisions of the Tornier Salto Talaris, a fixed-bearing TAA prosthesis, were reviewed. Medical records from index procedure to latest follow-up of primary TAA were reviewed. Complications were categorized according to the Glazebrook classification; additional complications were documented. Concurrent procedures were recorded, and radiographs were analyzed for alignment, subsidence, and cyst formation. Time to complication onset and learning curve analyses were performed. One hundred four Salto Talaris TAA prostheses (96 patients), with an average follow-up of 46 months, were included. Thirty-five complications were identified in 32 ankles with a 34% complication rate, resulting in 11 reoperations (5 TAA revisions). Technical error (n = 12), wound healing (n = 9), and aseptic loosening (n = 4) were the most common complications, and there were no statistically significant differences in demographics or follow-up duration between cases with versus without complications. In both the cohorts with and without complications, there were moderate, negative correlations between radiographically observed keel osteopenia and lucency (ρ = -0.548, P = .00125, and ρ = -0.416, P = .000303, respectively); also, in the complication cohort, a weak, positive correlation between subsidence and lucency (ρ = 0.357, P = .0450) was found. Salto Talaris TAA survivorship and reoperation rates in our series were comparable with previous reports, using either the same or similar mobile-bearing prostheses; new information regarding complication, radiographic, and learning curve analyses was presented. Level IV, retrospective case series.

  16. J-integral fracture toughness and tearing modulus measurement of radiation cross-linked UHMWPE.

    PubMed

    Gomoll, A; Wanich, T; Bellare, A

    2002-11-01

    Radiation and chemical cross-linking of medical grade ultrahigh molecular weight polyethylene (UHMWPE) has recently been utilized in an effort to improve wear performance of total joint replacement components. However, reductions in mechanical properties with cross-linking are cause for concern regarding the use of cross-linked UHMWPE for high-stress applications such as in total knee replacement prostheses. In this study, the fracture behavior of radiation cross-linked UHMWPE was compared to that of uncross-linked UHMWPE. The Rice and Sorensen model that utilizes mechanical parameters obtained from uniaxial tensile and compact tension tests was used to calculate the steady state J-integral fracture toughness, Jss, for radiation cross-linked UHMWPE. Jss decreased monotonically with increase in radiation dose. UHMWPE exhibited tough, ductile tearing behavior with stable crack growth when it was cross-linked using a gamma radiation dose of 0-50 kGy. However, in cross-linked UHMWPE irradiated to a dose of 100 and 200 kGy, unstable fracture occurred spontaneously upon attaining the initial crack driving force, J1c. This indicates that a high degree of cross-linking is less desirable for high-stress applications in orthopaedic implants. However, a substantial increase in J1c, even at a low degree of cross-linking, suggests that a low degree of cross-linking may be beneficial for resistance to delamination and catastrophic failure, both of which require an initiation step for the fracture to propagate in the material. This mechanical test should, however, be considered along with fatigue tests and joint simulator testing before determination of an appropriate amount of cross-linking for total joint replacement prostheses that experience high stresses.

  17. Gait Biomechanics of Individuals with Transtibial Amputation: Effect of Suspension System

    PubMed Central

    Eshraghi, Arezoo; Abu Osman, Noor Azuan; Karimi, Mohammad; Gholizadeh, Hossein; Soodmand, Ehsan; Abas, Wan Abu Bakar Wan

    2014-01-01

    Prosthetic suspension system is an important component of lower limb prostheses. Suspension efficiency can be best evaluated during one of the vital activities of daily living, i.e. walking. A new magnetic prosthetic suspension system has been developed, but its effects on gait biomechanics have not been studied. This study aimed to explore the effect of suspension type on kinetic and kinematic gait parameters during level walking with the new suspension system as well as two other commonly used systems (the Seal-In and pin/lock). Thirteen persons with transtibial amputation participated in this study. A Vicon motion system (six cameras, two force platforms) was utilized to obtain gait kinetic and kinematic variables, as well as pistoning within the prosthetic socket. The gait deviation index was also calculated based on the kinematic data. The findings indicated significant difference in the pistoning values among the three suspension systems. The Seal-In system resulted in the least pistoning compared with the other two systems. Several kinetic and kinematic variables were also affected by the suspension type. The ground reaction force data showed that lower load was applied to the limb joints with the magnetic suspension system compared with the pin/lock suspension. The gait deviation index showed significant deviation from the normal with all the systems, but the systems did not differ significantly. Main significant effects of the suspension type were seen in the GRF (vertical and fore-aft), knee and ankle angles. The new magnetic suspension system showed comparable effects in the remaining kinetic and kinematic gait parameters to the other studied systems. This study may have implications on the selection of suspension systems for transtibial prostheses. Trial Registration Iranian Registry of Clinical Trials IRCT2013061813706N1. PMID:24865351

  18. Mobility and satisfaction with a microprocessor-controlled knee in moderately active amputees: A multi-centric randomized crossover trial.

    PubMed

    Lansade, Céline; Vicaut, Eric; Paysant, Jean; Ménager, Doménico; Cristina, Marie-Christine; Braatz, Frank; Domayer, Stephan; Pérennou, Dominic; Chiesa, Gérard

    2018-05-14

    Microprocessor-controlled knees are generally prescribed and reimbursed for active amputees. Recent studies suggested that this technology could be useful for amputees with moderate activity level. We compared the efficiency of a microprocessor-controlled knee (MPK, Kenevo, Otto Bock) and non-MPKs (NMPKs) in these indications. A multi-centric randomized crossover trial was conducted in 16 hospitals from 3 European countries. Participants were randomized to an MPK-NMPK sequence, testing the MPK for 3 months and the NMPK for 1 month, or to an NMPK-MPK sequence, testing the NMPK for 1 month and the MPK for 3 months. Dynamic balance, the main criteria, was assessed with the Timed-Up and Go test (TUG), functional mobility with the Locomotor Capability Index (LCI-5), quality of life with the Medical Outcomes Study Short Form 36 v2 (SF-36v2) and satisfaction with the Quebec User Evaluation of Satisfaction with Assistive Technology 2.0. The occurrence of falls was monitored during the last month of trial. Analysis was by intent-to-treat and per-protocol (PP). We recruited 35 individuals with transfemoral amputation or knee disarticulation (27 males; mean age 65.6years [SD 10.1]). On PP analysis, dynamic balance and functional mobility were improved with the MPK, as shown by a reduced median TUG time (from 21.4s [Q1-Q3 19.3-26.6] to 17.9s [15.4-22.7], P=0.001) and higher mean global LCI-5 (from 40.4 [SD 7.6] to 42.8 [6.2], P=0.02). Median global satisfaction score increased (from 3.9 [Q1-Q3 3.8-4.4] to 4.7 [4.1-4.9], P=0.001) and quality of life was improved for the mental component summary of the SF-36v2 (median score from 53.3 [Q1-Q3 47.8-60.7] to 60.2 [51.6-62.6], P=0.03) and physical component summary but not significantly (mean score from 44.1 [SD 6.3] to 46.3 [7.0], P=0.08). Monitoring of adverse events including falls revealed no differences between both assessed devices. This study enhances the level of evidence to argue equal opportunity for all individuals with transfemoral amputation or knee disarticulation, regardless of their mobility grade, to be provided with appropriate prostheses. Copyright © 2018. Published by Elsevier Masson SAS.

  19. Evaluation of metal-polymeric fixed partial prosthesis using optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Sinescu, C.; Negrutiu, M. L.; Duma, V. F.; Marcauteanu, C.; Topala, F. I.; Rominu, M.; Bradu, A.; Podoleanu, A. Gh.

    2013-11-01

    Metal-Polymeric fixed partial prosthesis is the usual prosthetic treatment for many dental patients. However, during the mastication the polymeric component of the prosthesis is fractured and will be lost. This fracture is caused by the material defects or by the fracture lines trapped inside the esthetic components of the prosthesis. This will finally lead to the failure of the prosthetic treatment. Nowadays, there is no method of identification and forecast for the materials defects of the polymeric materials. The aim of this paper is to demonstrate the capability of Optical Coherence Tomography (OCT) as a non-invasive clinical method that can be used for the evaluation of metal-polymeric fixed partial prostheses. Twenty metal-polymeric fixed partial prostheses were used for this study. The esthetic component of the prostheses has been Adoro (Ivoclar). Optical investigations of the metal prostheses have revealed no material defects or fracture lines. All the prostheses were temporary cemented in the oral cavities of the patients for six month. The non-invasive method used for the investigations was OCT working in Time Domain mode at 1300 nm. The evaluations of the prostheses were performed before and after their cementation in the patient mouths. All the imagistic results were performed in 2D and than in 3D, after the reconstruction. The results obtained after the OCT evaluation allowed for the identification of 4 metal-polymeric fixed partial prostheses with material defects immediately after finishing the technological procedures. After 6 month in the oral environment other 3 fixed partial prostheses revealed fracture lines. In conclusion, OCT proved to be a valuable tool for the noninvasive evaluation of the metal-polymeric fixed partial prostheses.

  20. Implant-level prostheses in the edentulous maxilla: a comparison with conventional abutment-level prostheses after 5 years of use.

    PubMed

    Hjalmarsson, Lars; Smedberg, Jan-Ivan; Pettersson, Mattias; Jemt, Torsten

    2011-01-01

    Long-term comparisons of frameworks at the implant or abutment level are not available, and knowledge of the clinical function of cobalt-chromium (Co-Cr) alloy frameworks is limited. Primarily, the aim of this study was to compare the 5-year clinical performance of frameworks with or without abutment connections to implants. Secondly, the outcomes of prostheses made from Co-Cr alloy with porcelain veneers to those made of commercially pure titanium (CP Ti) with acrylic veneers were compared. The test groups comprised patients treated with screw-retained fixed prostheses made at the implant level according to the Cresco method in either dental porcelain-veneered Co-Cr alloy (n = 15) or acrylic-veneered CP Ti (n = 25). A control group of 40 randomly selected patients were provided with prostheses made at the standard abutment level in CP Ti with acrylic veneers. For all patients, clinical and radiologic 5-year data were retrospectively collected and evaluated. Five-year implant cumulative survival rates (CSRs) were 98.6% and 97.6% for test and control groups, respectively (P > .05). No major differences in bone level were demonstrated between the groups after 5 years (P > .05). Significantly more complications occurred in the test groups compared to the control group (P < .01), with the most common complications being mucositis and fracture of veneers. After 5 years, the clinical outcomes of implant-level prostheses made of porcelain-veneered Co-Cr or acrylic-veneered CP Ti seem comparable to acrylic-veneered titanium prostheses made at the standard abutment level regarding implant CSR and bone levels. However, more complications were registered in implant-level prostheses compared to the standard abutment-level prostheses.

  1. Fabrication of low cost soft tissue prostheses with the desktop 3D printer

    NASA Astrophysics Data System (ADS)

    He, Yong; Xue, Guang-Huai; Fu, Jian-Zhong

    2014-11-01

    Soft tissue prostheses such as artificial ear, eye and nose are widely used in the maxillofacial rehabilitation. In this report we demonstrate how to fabricate soft prostheses mold with a low cost desktop 3D printer. The fabrication method used is referred to as Scanning Printing Polishing Casting (SPPC). Firstly the anatomy is scanned with a 3D scanner, then a tissue casting mold is designed on computer and printed with a desktop 3D printer. Subsequently, a chemical polishing method is used to polish the casting mold by removing the staircase effect and acquiring a smooth surface. Finally, the last step is to cast medical grade silicone into the mold. After the silicone is cured, the fine soft prostheses can be removed from the mold. Utilizing the SPPC method, soft prostheses with smooth surface and complicated structure can be fabricated at a low cost. Accordingly, the total cost of fabricating ear prosthesis is about $30, which is much lower than the current soft prostheses fabrication methods.

  2. Fabrication of low cost soft tissue prostheses with the desktop 3D printer

    PubMed Central

    He, Yong; Xue, Guang-huai; Fu, Jian-zhong

    2014-01-01

    Soft tissue prostheses such as artificial ear, eye and nose are widely used in the maxillofacial rehabilitation. In this report we demonstrate how to fabricate soft prostheses mold with a low cost desktop 3D printer. The fabrication method used is referred to as Scanning Printing Polishing Casting (SPPC). Firstly the anatomy is scanned with a 3D scanner, then a tissue casting mold is designed on computer and printed with a desktop 3D printer. Subsequently, a chemical polishing method is used to polish the casting mold by removing the staircase effect and acquiring a smooth surface. Finally, the last step is to cast medical grade silicone into the mold. After the silicone is cured, the fine soft prostheses can be removed from the mold. Utilizing the SPPC method, soft prostheses with smooth surface and complicated structure can be fabricated at a low cost. Accordingly, the total cost of fabricating ear prosthesis is about $30, which is much lower than the current soft prostheses fabrication methods. PMID:25427880

  3. Assessment of the mechanical performance of titanium cranial prostheses manufactured by super plastic forming and single point incremental forming

    NASA Astrophysics Data System (ADS)

    Sgambitterra, Emanuele; Piccininni, Antonio; Guglielmi, Pasquale; Ambrogio, Giuseppina; Fragomeni, Gionata; Villa, Tomaso; Palumbo, Gianfranco

    2018-05-01

    Cranial implants are custom prostheses characterized by quite high geometrical complexity and small thickness; at the same time aesthetic and mechanical requirements have to be met. Titanium alloys are largely adopted for such prostheses, as they can be processed via different manufacturing technologies. In the present work cranial prostheses have been manufactured by Super Plastic Forming (SPF) and Single Point Incremental Forming (SPIF). In order to assess the mechanical performance of the cranial prostheses, drop tests under different load conditions were conducted on flat samples to investigate the effect of the blank thickness. Numerical simulations were also run for comparison purposes. The mechanical performance of the cranial implants manufactured by SPF and SPIF could be predicted using drop test data and information about the thickness evolution of the formed parts: the SPIFed prosthesis revealed to have a lower maximum deflection and a higher maximum force, while the SPFed prostheses showed a lower absorbed energy.

  4. Fabrication of low cost soft tissue prostheses with the desktop 3D printer.

    PubMed

    He, Yong; Xue, Guang-huai; Fu, Jian-zhong

    2014-11-27

    Soft tissue prostheses such as artificial ear, eye and nose are widely used in the maxillofacial rehabilitation. In this report we demonstrate how to fabricate soft prostheses mold with a low cost desktop 3D printer. The fabrication method used is referred to as Scanning Printing Polishing Casting (SPPC). Firstly the anatomy is scanned with a 3D scanner, then a tissue casting mold is designed on computer and printed with a desktop 3D printer. Subsequently, a chemical polishing method is used to polish the casting mold by removing the staircase effect and acquiring a smooth surface. Finally, the last step is to cast medical grade silicone into the mold. After the silicone is cured, the fine soft prostheses can be removed from the mold. Utilizing the SPPC method, soft prostheses with smooth surface and complicated structure can be fabricated at a low cost. Accordingly, the total cost of fabricating ear prosthesis is about $30, which is much lower than the current soft prostheses fabrication methods.

  5. Hip prostheses in young adults. Surface prostheses and short-stem prostheses.

    PubMed

    Gallart, X; Riba, J; Fernández-Valencia, J A; Bori, G; Muñoz-Mahamud, E; Combalia, A

    The poor results obtained in young patients when using a conventional prosthesis led to the resurgence of hip resurfacing to find less invasive implants for the bone. Young patients present a demand for additional activity, which makes them a serious challenge for the survival of implants. In addition, new information technologies contribute decisively to the preference for non-cemented prostheses. Maintaining quality of life, preserving the bone and soft tissues, as well as achieving a very stable implant, are the goals of every hip orthopaedic surgeon for these patients. The results in research point to the use of smaller prostheses, which use the metaphyseal zone more and less the diaphyseal zone, and hence the large number of the abovementioned short stem prostheses. Both models are principally indicated in the young adult. Their revision should be a more simple operation, but this is only true for hip resurfacing, not for short stems. Copyright © 2017 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  6. Composite Materials for Maxillofacial Prostheses.

    DTIC Science & Technology

    1981-08-01

    necessary and Identify byv block number) MAXILLOFACIAL PROSTHESES; PROSTHETIC MATERIALS: MICROCAPSULES : SOFT FILLERS; ELASTOMER COMPOSITES 2,. ABSTRACT...used as fillers in the fabrication of maxillofacial prostheses. The projected systems are elastomeric-shelled, liquid-filled microcapsules . Improvements...elastomeric-shelled, liquid-filled microcapsules . Experiments continued on the interfacial polymerization process, with spherical, sealed, capsules

  7. Morphological characterization of dental prostheses interfaces using optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Sinescu, Cosmin; Negrutiu, Meda L.; Ionita, Ciprian; Marsavina, Liviu; Negru, Radu; Caplescu, Cristiana; Bradu, Adrian; Topala, Florin; Rominu, Roxana O.; Petrescu, Emanuela; Leretter, Marius; Rominu, Mihai; Podoleanu, Adrian G.

    2010-03-01

    Fixed partial prostheses as integral ceramic, polymers, metal-ceramic or metal-polymers bridges are mainly used in the frontal part of the dental arch (especially the integral bridges). They have to satisfy high stress as well as esthetic requirements. The masticatory stress may induce fractures of the bridges. These may be triggered by initial materials defects or by alterations of the technological process. The fractures of these bridges lead to functional, esthetic and phonetic disturbances which finally render the prosthetic treatment inefficient. Dental interfaces represent one of the most significant aspects in the strength of the dental prostheses under the masticatory load. The purpose of this study is to evaluate the capability of optical coherence tomography (OCT) to characterize the dental prostheses interfaces. The materials used were several fixed partial prostheses integral ceramic, polymers, metal-ceramic and metal-polymers bridges. It is important to produce both C-scans and B-scans of the defects in order to differentiate morphological aspects of the bridge infrastructures. The material defects observed with OCT were investigated with micro-CT in order to prove their existence and positions. In conclusion, it is important to have a non invasive method to investigate dental prostheses interfaces before the insertion of prostheses in the oral cavity.

  8. [Clinical evaluation of "All-on-Four" provisional prostheses reinforced with carbon fibers].

    PubMed

    Li, Bei-bei; Lin, Ye; Cui, Hong-yan; Hao, Qiang; Xu, Jia-bin; Di, Ping

    2016-02-18

    To assess the clinical effects of carbon fiber reinforcement on the "All-on-Four" provisional prostheses. Provisional prostheses were divided into control group and carbon fiber reinforcing group according to whether carbon fiber reinforcement was used in the provisional prostheses base resin. In our study, a total of 60 patients (32 males and 28 females) with 71 provisional prostheses(28 maxilla and 43 mandible)were enrolled between April 2008 and December 2012 for control group; a total of 23 patients (13 males and 10 females) with 28 provisional prostheses (9 maxillas and 19 mandibles) were enrolled between January 2013 and March 2014 for carbon fiber reinforcing group. The information of provisional prostheses in the patients was recorded according to preoperative examination. We used the date of definitive prosthesis restoration as the cut-off point, observing whether fracture occurred on the provisional prostheses in the two groups. Additionally we observed whether fiber exposure occurred on the tissue surface of the provisional prostheses and caused mucosal irritation. The interface between the denture base resin and the fibers was examined using scanning electron microscopy (SEM). The age [(57.3 ± 10.1) years vs.(55.1 ± 11.4) years], gender (32 males and 28 females vs. 13 males and 10 females), maxilla and mandible distributions (28 maxillas and 43 mandibles vs. 9 maxillas and 19 mandibles), the number of extraction jaws (46 vs. 23), the average using time [(7.8 ± 1.3) months vs. (7.5 ± 1.1) months], and the opposing dentition distributions of provisional prostheses of the patients showed no significant differences between the control and reinforcing groups. There were 21(29.6%) fractures that occurred on the 71 provisional prostheses in the control group; there was no fracture that occurred on the 28 provisional prosthesesin the carbon fiber reinforcing group. The fracture rate of the carbon fiber reinforcing group was significantly lower than that of the control group (P=0.001). No carbon fiber exposure and mucosal irritation were observed from clinical examination.SEM revealed relatively continuous contact between the fiber and acrylic resin, and the resin particles adhered on the surface of the carbon fibers. The addition of carbon fibers between abutments placed on "All-on-Four" provisional fixed denture base resin may be clinically effective in preventing "All-on-Four" denture fracture and can provide several advantages for clinical use.

  9. Characterizing the Mechanical Properties of Running-Specific Prostheses

    PubMed Central

    Beck, Owen N.; Taboga, Paolo; Grabowski, Alena M.

    2016-01-01

    The mechanical stiffness of running-specific prostheses likely affects the functional abilities of athletes with leg amputations. However, each prosthetic manufacturer recommends prostheses based on subjective stiffness categories rather than performance based metrics. The actual mechanical stiffness values of running-specific prostheses (i.e. kN/m) are unknown. Consequently, we sought to characterize and disseminate the stiffness values of running-specific prostheses so that researchers, clinicians, and athletes can objectively evaluate prosthetic function. We characterized the stiffness values of 55 running-specific prostheses across various models, stiffness categories, and heights using forces and angles representative of those measured from athletes with transtibial amputations during running. Characterizing prosthetic force-displacement profiles with a 2nd degree polynomial explained 4.4% more of the variance than a linear function (p<0.001). The prosthetic stiffness values of manufacturer recommended stiffness categories varied between prosthetic models (p<0.001). Also, prosthetic stiffness was 10% to 39% less at angles typical of running 3 m/s and 6 m/s (10°-25°) compared to neutral (0°) (p<0.001). Furthermore, prosthetic stiffness was inversely related to height in J-shaped (p<0.001), but not C-shaped, prostheses. Running-specific prostheses should be tested under the demands of the respective activity in order to derive relevant characterizations of stiffness and function. In all, our results indicate that when athletes with leg amputations alter prosthetic model, height, and/or sagittal plane alignment, their prosthetic stiffness profiles also change; therefore variations in comfort, performance, etc. may be indirectly due to altered stiffness. PMID:27973573

  10. Rapid prototyping--when virtual meets reality.

    PubMed

    Beguma, Zubeda; Chhedat, Pratik

    2014-01-01

    Rapid prototyping (RP) describes the customized production of solid models using 3D computer data. Over the past decade, advances in RP have continued to evolve, resulting in the development of new techniques that have been applied to the fabrication of various prostheses. RP fabrication technologies include stereolithography (SLA), fused deposition modeling (FDM), computer numerical controlled (CNC) milling, and, more recently, selective laser sintering (SLS). The applications of RP techniques for dentistry include wax pattern fabrication for dental prostheses, dental (facial) prostheses mold (shell) fabrication, and removable dental prostheses framework fabrication. In the past, a physical plastic shape of the removable partial denture (RPD) framework was produced using an RP machine, and then used as a sacrificial pattern. Yet with the advent of the selective laser melting (SLM) technique, RPD metal frameworks can be directly fabricated, thereby omitting the casting stage. This new approach can also generate the wax pattern for facial prostheses directly, thereby reducing labor-intensive laboratory procedures. Many people stand to benefit from these new RP techniques for producing various forms of dental prostheses, which in the near future could transform traditional prosthodontic practices.

  11. [Effect of CO2 laser on prostheses used in middle ear surgery].

    PubMed

    Szymański, Marcin

    2005-01-01

    The use of CO2 laser is advocated in primary and revision stapes surgery. The aim of the study was to assess the effect of CO2 laser on stapes prostheses. CO2 laser was applied on several types of stapes prostheses and PORPs, with power settings suggested by the manufacturer (continuous wave, 2 W and 6 W; 0,05 s). Application of the laser on stainless steel or titanium prosthesis did not exert any effect on the structure of the prosthesis. The use of the laser on the Teflon piston caused superficial burning with power 2 W, and melting and holes in the piston with power settings at 6W. Similar plastipore prostheses were melting. Hydroxyapatite PORP shattered after application of the laser energy. Teflon and hydroxyapatite prostheses are easily damaged by the laser energy, therefore applying a laser on them should be avoided. CO2 laser can be used on stainless steel and titanium prostheses without risk of damaging them. However the possibility of transmission of heat to the vestibule has to be taken into consideration.

  12. Success and complications of implant-retained prostheses provided by the Post-Doctoral Prosthodontics Program, University of Puerto Rico: a cross-sectional study.

    PubMed

    Loza-Herrero, María A; Rivas-Tumanyan, Sona; Morou-Bermudez, Evangelia

    2015-11-01

    The success rate of implant-retained prostheses in a postdoctoral prosthodontics program was unknown and could not be related to any set of potential clinical issues or patient characteristics. The purpose of this study was to determine the success rate of implant-retained prostheses placed by prosthodontic residents between 1997 and 2012 and to evaluate the associations between patient classifications and specific restoration characteristics as related to prosthesis success or failure. A total of 272 prostheses in 119 patients were clinically evaluated. Success was defined as the absence of prosthetic complications or any implant-related complication that affected prosthesis survival. Logistic regression was used to evaluate associations between prosthesis success/failure and a wide array of study variables, adjusting for patient age, sex, and prosthesis longevity. The overall success rate was 71%, with a mean prosthesis age of 4.5 years (range: 4 months to 16.8 years). Implant single crowns were the most successful prosthesis type (81% success). The most common complications observed were porcelain fractures in fixed dental prostheses (15%) and lack of stability (31%) and retention (29%) in removable dental prostheses. Having a removable prosthesis (versus natural dentition) in the opposing occlusion significantly decreased the odds of success (OR=0.26, 95% CI: 0.11-0.64). Definitively cemented fixed prostheses were more successful than those cemented with an interim cement (OR=4.56, 95% CI: 1.37-15.22). The overall success rate of the implant-retained prostheses placed in the program was low compared with previously published studies. This study revealed the need for an efficient, comprehensive recall system for patients receiving implant-retained prostheses, either fixed or removable. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  13. Fiber-reinforced composite fixed dental prostheses: two clinical reports.

    PubMed

    Zarow, Maciej; Paisley, Carl Stuart; Krupinski, Jerzy; Brunton, Paul Anthony

    2010-06-01

    Various options are available in clinical practice for the replacement of a single missing tooth, ranging from conventional fixed and removable dental prostheses to a single implant-supported crown. There are situations in which a semipermanent fixed dental prosthesis may be desirable, particularly for patients who have completed orthodontic treatment but are too young to embark on implant therapy. Following advances in fiber-reinforcement technology, fiber-reinforced composite resin (FRC) now represents a lower-cost alternative to traditional metal-ceramic for the construction of resin-bonded prostheses. Two case reports illustrate the use of FRC prostheses as fixed semipermanent_restorations.

  14. Peri-apatite coating decreases uncemented tibial component migration: long-term RSA results of a randomized controlled trial and limitations of short-term results.

    PubMed

    Van Hamersveld, Koen T; Marang-Van De Mheen, Perla J; Nelissen, Rob G H H; Toksvig-Larsen, Sören

    2018-05-09

    Background and purpose - Biological fixation of uncemented knee prostheses can be improved by applying hydroxyapatite coating around the porous surface via a solution deposition technique called Peri-Apatite (PA). The 2-year results of a randomized controlled trial, evaluating the effect of PA, revealed several components with continuous migration in the second postoperative year, particularly in the uncoated group. To evaluate whether absence of early stabilization is diagnostic of loosening, we now present long-term follow-up results. Patients and methods - 60 patients were randomized to PA-coated or uncoated (porous only) total knee arthroplasty of which 58 were evaluated with radiostereometric analysis (RSA) performed at baseline, at 3 months postoperatively and at 1, 2, 5, 7, and 10 years. A linear mixed-effects model was used to analyze the repeated measurements. Results - PA-coated components had a statistically significantly lower mean migration at 10 years of 0.94 mm (95% CI 0.72-1.2) compared with the uncoated group showing a mean migration of 1.72 mm (95% CI 1.4-2.1). Continuous migration in the second postoperative year was seen in 7 uncoated components and in 1 PA-coated component. All of these implants stabilized after 2 years except for 2 uncoated components. Interpretation - Peri-apatite enhances stabilization of uncemented components. The number of components that stabilized after 2 years emphasizes the importance of longer follow-up to determine full stabilization and risk of loosening in uncemented components with biphasic migration profiles.

  15. [The accuracy of palpation from orientation points for the navigated implantation of knee prostheses].

    PubMed

    Fuiko, R; Kotten, B; Zettl, R; Ritschl, P

    2004-03-01

    Cinematic and pointing procedures are used for non-image based navigated implantation during total knee replacement. Pointing procedures require an exact knowledge of the landmarks. In this anatomical study, landmarks are defined and repeatedly referenced. Precision and reproducibility are evaluated by means of an inter- and an intra-observer study. The axes of the femur and tibia are calculated using the landmarks. The specific landmarks of 30 femurs and 27 tibias were palpated by three surgeons and digitised by means of a photogrammetric system, as used intra-operatively. The recorded data were statistically evaluated. The specific landmarks can be referenced with great precision. The vectors that influence the implant position show a mean femoral deviation of 0.9 mm and a mean tibial deviation of 1.0 mm. The repeating accuracy of every observer was 1.5 mm femoral and 1.0 mm tibial. The calculated long axes at the femur and tibia thus reach a precision of 0.1 degrees (min.-max.: 0-0.9 degrees) at the femur and 0.2 degrees (.0-1.1 degrees) at the tibia. The short axes at the distal femur and proximal tibia exhibit an average deviation of from 0.7 degrees to 1.9 degrees (0-11.3 degrees). Long axes (mechanical axes) can be determined exactly but the precision of the short axes (rotational axes) is unsatisfactory, although palpation of landmarks was accurate. Therefore, palpation of more than one rotational axis at the femur and tibia is mandatory and should be visualized on the monitor during surgery.

  16. Performance of local optimization in single-plane fluoroscopic analysis for total knee arthroplasty.

    PubMed

    Prins, A H; Kaptein, B L; Stoel, B C; Lahaye, D J P; Valstar, E R

    2015-11-05

    Fluoroscopy-derived joint kinematics plays an important role in the evaluation of knee prostheses. Fluoroscopic analysis requires estimation of the 3D prosthesis pose from its 2D silhouette in the fluoroscopic image, by optimizing a dissimilarity measure. Currently, extensive user-interaction is needed, which makes analysis labor-intensive and operator-dependent. The aim of this study was to review five optimization methods for 3D pose estimation and to assess their performance in finding the correct solution. Two derivative-free optimizers (DHSAnn and IIPM) and three gradient-based optimizers (LevMar, DoNLP2 and IpOpt) were evaluated. For the latter three optimizers two different implementations were evaluated: one with a numerically approximated gradient and one with an analytically derived gradient for computational efficiency. On phantom data, all methods were able to find the 3D pose within 1mm and 1° in more than 85% of cases. IpOpt had the highest success-rate: 97%. On clinical data, the success rates were higher than 85% for the in-plane positions, but not for the rotations. IpOpt was the most expensive method and the application of an analytically derived gradients accelerated the gradient-based methods by a factor 3-4 without any differences in success rate. In conclusion, 85% of the frames can be analyzed automatically in clinical data and only 15% of the frames require manual supervision. The optimal success-rate on phantom data (97% with IpOpt) on phantom data indicates that even less supervision may become feasible. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Predicting 3D pose in partially overlapped X-ray images of knee prostheses using model-based Roentgen stereophotogrammetric analysis (RSA).

    PubMed

    Hsu, Chi-Pin; Lin, Shang-Chih; Shih, Kao-Shang; Huang, Chang-Hung; Lee, Chian-Her

    2014-12-01

    After total knee replacement, the model-based Roentgen stereophotogrammetric analysis (RSA) technique has been used to monitor the status of prosthetic wear, misalignment, and even failure. However, the overlap of the prosthetic outlines inevitably increases errors in the estimation of prosthetic poses due to the limited amount of available outlines. In the literature, quite a few studies have investigated the problems induced by the overlapped outlines, and manual adjustment is still the mainstream. This study proposes two methods to automate the image processing of overlapped outlines prior to the pose registration of prosthetic models. The outline-separated method defines the intersected points and segments the overlapped outlines. The feature-recognized method uses the point and line features of the remaining outlines to initiate registration. Overlap percentage is defined as the ratio of overlapped to non-overlapped outlines. The simulated images with five overlapping percentages are used to evaluate the robustness and accuracy of the proposed methods. Compared with non-overlapped images, overlapped images reduce the number of outlines available for model-based RSA calculation. The maximum and root mean square errors for a prosthetic outline are 0.35 and 0.04 mm, respectively. The mean translation and rotation errors are 0.11 mm and 0.18°, respectively. The errors of the model-based RSA results are increased when the overlap percentage is beyond about 9%. In conclusion, both outline-separated and feature-recognized methods can be seamlessly integrated to automate the calculation of rough registration. This can significantly increase the clinical practicability of the model-based RSA technique.

  18. Composite Materials for Maxillofacial Prostheses.

    DTIC Science & Technology

    1979-08-01

    block number) MAXILLOFACIAL PROSTHESES; PROSTHETIC MATERIALS; MICROCAPSULES ; SOFT FILLERS; ELASTuMER COMPOSITES 20,_ ABSTRACT ’Continue on reverse side...approaches were pursued toward making such microcapsules . One approach involves coaxial extrusion of a catalyzed elastomer precursor and core liquid into a...fabrication of maxillofacial prostheses. The projected composite systems are elastomeric-shelled, liquid-filled microcapsules . Two experimental approaches were

  19. Three-Dimensional (3-D) Printing: A Cost-Effective Solution for Improving Global Accessibility to Prostheses.

    PubMed

    Silva, Kyle; Rand, Stephanie; Cancel, David; Chen, Yuxi; Kathirithamby, Rani; Stern, Michelle

    2015-12-01

    The lack of access to prostheses is a global problem, partially caused by the high cost associated with the current manufacturing process. Three-dimensional printing is gaining use in the medical field, and one such area is prosthetics. In addition to using cost-effective materials, this technology allows for rapid prototyping, making it an efficient solution for the development of affordable prostheses. If the rehabilitation medicine community embraces this novel technology, we can help alleviate the global disparity of access to prostheses. Copyright © 2015 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  20. [Significance of various implantate localizations of Sparks prostheses, experimental studies in rats].

    PubMed

    Brieler, H S; Parwaresch, R; Thiede, A

    1976-01-01

    Our investigations show that Sparks prostheses after subcutaneous implantation are suitable for vascular grafting. At the end of the organization period the connective tissue becomes strong, and after the third and fourth weeks collagenous and elastic fibers can be seen. Ten weeks after s.c. implantation, collagenous fibers predominate. After this the Sparks prostheses can be used as a vascular graft. Intraperitoneal implantation, however, shows a histologically different picture with characteristic findings: only fat cells can be observed, a strong granulation tissue with elastic and collagenous fibers is not present. After intraperitoneal implantation Sparks prostheses are therefore unsuitable for vascular grafts.

  1. Surgical treatment of tracheal collapse using pliable total ring prostheses: results in one experimental and 4 clinical cases.

    PubMed Central

    Ayres, S A; Holmberg, D L

    1999-01-01

    Pliable total ring prostheses were created from the polyvinyl chloride drip chambers of intravenous administration sets. The total ring prostheses were placed in one clinically normal research dog and in 4 client-owned dogs diagnosed with tracheal collapse. The research dog was euthanized one month after placement of the prostheses. Histopathological analysis of the trachea adjacent to the prostheses revealed a mild inflammatory response. The follow-up period for the clinical cases was from 4 months to 11 years. Radiographs taken and fluoroscopy performed 1 day to 5 months after surgery revealed improvement or resolution of the tracheal collapse. One dog was asymptomatic 28 weeks following surgery. Two dogs died 7 and 9 years after surgery, with one requiring intermittent medical management for coughing. They were euthanized for nonrespiratory illness. One dog had a persistent nonproductive cough, due to collapse of the mainstem bronchi, when last evaluated 4 months postoperatively. Pliable total ring prostheses provided adequate stability to the trachea and had the advantage of conforming to the trachea and being easy to create, place, and suture. Images Figure 1. Figure 2. PMID:10563237

  2. Coplanar intensity-modulated radiotherapy class solution for patients with prostate cancer with bilateral hip prostheses with and without nodal involvement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Young K., E-mail: Young.Lee@rmh.nhs.uk; McVey, Gerard P.; South, Chris P.

    2013-07-01

    Dose distributions for prostate radiotherapy are difficult to predict in patients with bilateral hip prostheses in situ, due to image distortions and difficulty in dose calculation. The feasibility of delivering curative doses to prostate using intensity-modulated radiotherapy (IMRT) in patients with bilateral hip prostheses was evaluated. Planning target volumes for prostate only (PTV1) and pelvic nodes (PTV2) were generated from data on 5 patients. PTV1 and PTV2 dose prescriptions were 70 Gy and 60 Gy, respectively, in 35 fractions, and an additional nodal boost of 65 Gy was added for 1 plan. Rectum, bladder, and bowel were also delineated. Beammore » angles and segments were chosen to best avoid entering through the prostheses. Dose-volume data were assessed with respect to clinical objectives. The plans achieved the required prescription doses to the PTVs. Five-field IMRT plans were adequate for patients with relatively small prostheses (head volumes<60 cm{sup 3}) but 7-field plans were required for patients with larger prostheses. Bowel and bladder doses were clinically acceptable for all patients. Rectal doses were deemed clinically acceptable, although the V{sub 50} {sub Gy} objective was not met for 4/5 patients. We describe an IMRT solution for patients with bilateral hip prostheses of varying size and shape, requiring either localized or whole pelvic radiotherapy for prostate cancer.« less

  3. Clinical outcome and complications of thoracic and pelvic limb stump and socket prostheses.

    PubMed

    Phillips, Andrew; Kulendra, Elvin; Bishop, Edith; Monk, Michelle; Parsons, Kevin; House, Arthur

    2017-07-20

    To describe the use, quality of life, compliance, complications, and outcome of animals fitted with stump socket prostheses. Medical records of dogs fitted with a stump socket prosthesis were reviewed. Functional outcome, quality of life and complications were retrospectively assessed from an owner questionnaire. Thirteen stump socket prostheses (12 dogs) were fitted for a variety of reasons including trauma, congenital abnormalities, and neoplasia. Eight dogs had a good outcome overall and four a poor outcome. Quality of life (QOL) remained good or excellent in 10/12 dogs. Nine complications were seen in 7/12 dogs, most were manageable; surgical wound complications (n = 2) and pressures sores (n = 4) were the most frequently encountered. One dog suffered multiple complications. Thoracic and pelvic limb stump socket prostheses had a similar complication rate, however all animals with a poor outcome had a thoracic limb stump socket prosthesis; two were small breed dogs (under 10 kg) and two had bilateral thoracic limb abnormalities. Stump socket prostheses are feasible and versatile in animals. In correctly selected cases, good to excellent outcomes are possible. However, complications are frequent but often manageable. Further investigations are required into the risk factors for poor outcomes and prospective studies are required to assess changes in biomechanics, function, and QOL before and after fitting of a stump socket prosthesis. Until further evidence is available, careful consideration should be given before fitting bilateral thoracic limb stump socket prostheses or thoracic limb stump socket prostheses to small breed dogs.

  4. In vivo testing of porous Ti-25Nb alloy serving as a femoral stem prosthesis in a rabbit model

    PubMed Central

    Weng, Xiaojun; Yang, Hailin; Xu, Jian; Li, Xiaosheng; Liao, Qiande; Wang, Jing

    2016-01-01

    The aim of the present study was to observe the performance of Ti-25Nb alloys with various porosities as femoral stem prostheses in a rabbit model, thus providing basic experimental evidence for the development of porous prostheses. The porous Ti-25Nb alloy prostheses were designed according to the morphology of the medullary cavity. These prostheses were placed into the femoral medullary cavities in 36 New Zealand white rabbits. Postoperative X-ray films, scanning electron microscopy (SEM) of the implant interface, energy-dispersive spectroscopy (EDS) analysis of the implant surface, pulling-out test and general observations were conducted. The specimens showed good biocompatibility; there was no obvious bone absorption in porous Ti-25Nb specimens with different porosities at different time points observed using X-ray films. Under SEM examination, calcium deposits were observed inside the pores and in the interface between bone and prostheses. The EDS analysis demonstrated that calcium deposits were present on the surface of the prostheses at the eight-week point postoperatively. The pulling-out test showed good bonding strength between bone and implant; after pulling out, the surface and inside the pores of the prostheses all presented bone mass. Porous Ti-25Nb alloy implants presents good biocompatibility as well as providing a biological fixation between the bone and implant. A porosity of 70% is more advantageous to the newborn bone ingrowth, combined with achieving a more solid bone-implant interface. PMID:27602063

  5. Computerized design of speech prostheses.

    PubMed

    Leonard, R J

    1991-08-01

    The use of computerized techniques to assist in the design of palatal and/or glossal prostheses is described. Patients with oropharyngeal resection and associated speech impairment are candidates for such prostheses. Procedures discussed allow for the design of some features of the prosthesis, such as shape, location, and tests of its effect on certain speech parameters, prior to actual fabrication. Advantages and current limitations of the techniques are also discussed.

  6. Access to Breast Prostheses via a Government-Funded Service in Victoria, Australia: Experience of Women and Service Providers

    ERIC Educational Resources Information Center

    Livingston, Patricia M.; White, Victoria; Roberts, Susan; Pritchard, Emma; Gibbs, Anne; Hill, David J.

    2003-01-01

    For many women, the only alternative to breast reconstruction following a mastectomy is to use external prostheses, which need replacing regularly at a cost of up to $395 per prosthesis. Commonwealth and state governments across Australia have responded to this need by providing subsidies to assist in the purchase of breast prostheses. However,…

  7. Prostheses for stapes surgery.

    PubMed

    Slattery, W H; House, J W

    1995-04-01

    A variety of different implants are available today for use by the otologic surgeon. All prostheses are well tolerated, and the risks of complication as a result of their implantation are comparable. The most commonly used prostheses are the wire-Teflon piston and the stainless steel bucket handle. Although the otologic surgeon has a wide variety of prostheses to choose from, most have a preference for one particular type. Results of hearing improvement following a successful stapedectomy is more a function of the surgeon's experience than of the type of prosthesis used. As James L. Sheehy, MD, so often says, "if a technique is working well for you, don't change for change's sake" (personal communication, 1994).

  8. Metalworking defects in surgery screws as a possible cause of post-surgical infections

    NASA Astrophysics Data System (ADS)

    Spector, Mario; Peretti, Leandro E.; Romero, Gustavo

    2016-04-01

    In the first phase of this work, surface defects (metalworking) in stainless steel implantable prostheses and their possible relation to infections that can be generated after surgery was studied. In a second phase, the results obtained in the aforementioned stage were applied to knee cruciate ligaments surgery screws, considering the fact that a substantial number of Mucormycetes infections have been reported after arthroscopic surgery in Argentina since the year 2005. Two types of screws, transverse and interference screws, were analyzed. The Allen heads presented defects such as burrs and metalworking bending as a result of the machining process. These defects allow the accumulation of machining oil, which could be contaminated with fungal spores. When this is the case, the gaseous sterilization by ethylene oxide may be jeopardized. Cortical screws were also analyzed and were found to present serious metalworking defects inside their heads. To reduce the risk of infection in surgery, the use of screws with metalworking defects on the outer surface, analyzed with stereomicroscope and considering the inside part of the Allen as an outer surface, should be avoided altogether.

  9. Characterization and Accelerated Ageing of UHMWPE Used in Orthopedic Prosthesis by Peroxide

    PubMed Central

    Rocha, Magda; Mansur, Alexandra; Mansur, Herman

    2009-01-01

    Ultra-high molecular weight polyethylene (UHMWPE) has been the most commonly used bearing material in total joint arthroplasty. Wear and oxidation fatigue resistance of UHMWPE are regarded as two important mechanical properties to extend the longevity of knee prostheses. Though accelerated in vitro protocols have been developed to test the relative oxidation resistance of various types of UHMWPE, its mechanism is not accurately understood yet. Thus, in the present study an accelerated ageing of UHMWPE in hydrogen peroxide solution was performed and relative oxidation was extensively characterized by Fourier Transformed Infrared Spectroscopy (FTIR) spectroscopy and the morphological changes were analyzed by Scanning Electron Microscopy (SEM). Different chemical groups of UHMWPE associated with the degradation reaction were monitored for over 120 days in order to evaluate the possible oxidation mechanism(s) which may have occurred. The results have provided strong evidence that the oxidation mechanism is rather complex, and two stages with their own particular first-order kinetics reaction patterns have been clearly identified. Furthermore, hydrogen peroxide has proven to be an efficient oxidative medium to accelerate ageing of UHMWPE.

  10. Macrophage Response to UHMWPE Submitted to Accelerated Ageing in Hydrogen Peroxide

    PubMed Central

    Rocha, Magda F.G.; Mansur, Alexandra A.P.; Martins, Camila P.S.; Barbosa-Stancioli, Edel F.; Mansur, Herman S.

    2010-01-01

    Ultra-high molecular weight polyethylene (UHMWPE) has been the most commonly used bearing material in total joint arthroplasty. Wear and oxidation fatigue resistance of UHMWPE are regarded as two important properties to extend the longevity of knee prostheses. The present study investigated the accelerated ageing of UHMWPE in hydrogen peroxide highly oxidative chemical environment. The sliced samples of UHMWPE were oxidized in a hydrogen peroxide solution for 120 days with their total level of oxidation (Iox) characterized by Fourier Transformed Infrared Spectroscopy (FTIR). The potential inflammatory response, cell viability and biocompatibility of such oxidized UHMWPE systems were assessed by a novel biological in vitro assay based on the secretion of nitric oxide (NO) by activated murine macrophages with gamma interferon (IFN-γ) cytokine and lipopolysaccharide (LPS). Furthermore, macrophage morphologies in contact with UHMWPE oxidized surfaces were analyzed by cell spreading-adhesion procedure using scanning electron microscopy (SEM). The results have given significant evidence that the longer the period of accelerated aging of UHMWPE the higher was the macrophage inflammatory equivalent response based on NO secretion analysis. PMID:20721321

  11. Speech assessment of patients using three types of indwelling tracheo-oesophageal voice prostheses.

    PubMed

    Heaton, J M; Sanderson, D; Dunsmore, I R; Parker, A J

    1996-04-01

    A multidisciplinary prospective study compared speech acceptability between three types of indwelling tracheo-oesophageal voice prostheses. Twenty male laryngectomees took part over five years, using 42 prostheses. Speech was assessed on a discrete scale by trained and untrained personnel. The majority scored in the mid-range for each assessor. The kappa coefficient was used to test similarity between assessors, and for all pairings agreement was significant (p < 0.05). The speech and language therapist tended to give higher scores and the patient lower. A relationship was found between patients' ages categorized by decade and the surgeon's score alone. This relationship held for Groningen high resistance and Provox prostheses individually too (p < 0.05). The untrained assessed similarly to the professionals--humans are all voice listeners. The analysis suggests surgeons find tracheo-oesophageal speech in older patients better than in younger ones; or make more allowances for the elderly. There was a trend for Provox prostheses to produce the best scores.

  12. Optical coherence tomography and confocal microscopy investigations of dental prostheses

    NASA Astrophysics Data System (ADS)

    Negrutiu, Meda L.; Sinescu, Cosmin; Hughes, Michael; Bradu, Adrian; Rominu, Mihai; Todea, Carmen; Dobre, George; Podoleanu, Adrian

    2008-09-01

    Dental prostheses are very complex systems, heterogenous in structure, made up from various materials, with different physical properties. An essential question mark is on the physical, chemical and mechanical compatibility between these materials. They have to satisfy high stress requirements as well as esthetic challenges. The masticatory stress may induce fractures of the prostheses, which may be triggered by initial materials defects or by alterations of the technological process. The failures of dental prostheses lead to functional, esthetic and phonetic disturbances which finally render the prosthetic treatment inefficient. The purpose of this study is to evaluate the capability of en-face optical coherence tomography as a possible non-invasive high resolution method in supplying the necessary information on the material defects of dental prostheses and microleakage at prosthetic interfaces. C-scan and B-scan OCT images as well as confocal images are acquired from a large range of samples. Gaps between the dental interfaces and material defects are clearly exposed. We conclude that OCT can successfully be used as a noninvasive analysis method.

  13. Using speech for mode selection in control of multifunctional myoelectric prostheses.

    PubMed

    Fang, Peng; Wei, Zheng; Geng, Yanjuan; Yao, Fuan; Li, Guanglin

    2013-01-01

    Electromyogram (EMG) recorded from residual muscles of limbs is considered as suitable control information for motorized prostheses. However, in case of high-level amputations, the residual muscles are usually limited, which may not provide enough EMG for flexible control of myoelectric prostheses with multiple degrees of freedom of movements. Here, we proposed a control strategy, where the speech signals were used as additional information and combined with the EMG signals to realize more flexible control of multifunctional prostheses. By replacing the traditional "sequential mode-switching (joint-switching)", the speech signals were used to select a mode (joint) of the prosthetic arm, and then the EMG signals were applied to determine a motion class involved in the selected joint and to execute the motion. Preliminary results from three able-bodied subjects and one transhumeral amputee demonstrated the proposed strategy could achieve a high mode-selection rate and enhance the operation efficiency, suggesting the strategy may improve the control performance of commercial myoelectric prostheses.

  14. Sport prostheses and prosthetic adaptations for the upper and lower limb amputees: an overview of peer reviewed literature.

    PubMed

    Bragaru, Mihai; Dekker, Rienk; Geertzen, Jan H B

    2012-09-01

    Sport prostheses are used by both upper- and lower-limb amputees while participating in sports and other physical activities. Although the number of these devices has increased over the past decade, no overview of the peer reviewed literature describing them has been published previously. Such an overview will allow specialists to choose appropriate prostheses based on available scientific evidence rather than on personal experience or preference. To provide an overview of the sport prostheses as they are described by the papers published in peer reviewed literature. Literature review. Four electronic databases were searched using free text and Medical Subject Headings (MESH) terms. Papers were included if they concerned a prosthesis or a prosthetic adaptation used in sports. Papers were excluded if they did not originate from peer reviewed sources, if they concerned prostheses for body parts other than the upper or lower limbs, if they concerned amputations distal to the wrist or ankle, or if they were written in a language other than English. Twenty-four papers were included in this study. The vast majority contained descriptive data and consisted of expert opinions and technical notes. Data concerning the energy efficiency, technical characteristics and special mechanical properties of prostheses or prosthetic adaptations for sports, other than running, are scarce.

  15. Differences in myoelectric and body-powered upper-limb prostheses: Systematic literature review.

    PubMed

    Carey, Stephanie L; Lura, Derek J; Highsmith, M Jason

    2015-01-01

    The choice of a myoelectric or body-powered upper-limb prosthesis can be determined using factors including control, function, feedback, cosmesis, and rejection. Although body-powered and myoelectric control strategies offer unique functions, many prosthesis users must choose one. A systematic review was conducted to determine differences between myoelectric and body-powered prostheses to inform evidence-based clinical practice regarding prescription of these devices and training of users. A search of 9 databases identified 462 unique publications. Ultimately, 31 of them were included and 11 empirical evidence statements were developed. Conflicting evidence has been found in terms of the relative functional performance of body-powered and myoelectric prostheses. Body-powered prostheses have been shown to have advantages in durability, training time, frequency of adjustment, maintenance, and feedback; however, they could still benefit from improvements of control. Myoelectric prostheses have been shown to improve cosmesis and phantom-limb pain and are more accepted for light=intensity work. Currently, evidence is insufficient to conclude that either system provides a significant general advantage. Prosthetic selection should be based on a patient's individual needs and include personal preferences, prosthetic experience, and functional needs. This work demonstrates that there is a lack of empirical evidence regarding functional differences in upper-limb prostheses.

  16. Robotic cadaver testing of a new total ankle prosthesis model (German Ankle System).

    PubMed

    Richter, Martinus; Zech, Stefan; Westphal, Ralf; Klimesch, Yvone; Gosling, Thomas

    2007-12-01

    An investigation was carried out into possible increased forces, torques, and altered motions during load-bearing ankle motion after implantation of two different total ankle prostheses. We hypothesized that the parameters investigated would not differ in relation to the two implants compared. We included two different ankle prostheses (Hintegra, Newdeal, Vienne, France; German Ankle System, R-Innovation, Coburg, Germany). The prostheses were implanted in seven paired cadaver specimens. The specimens were mounted on an industrial robot that enables complex motion under predefined conditions (RX 90, Stäubli, Bayreuth, Germany). The robot detected the load-bearing (30 kg) motion of the 100(th) cycle of the specimens without prostheses as the baseline for the later testing, and mimicked that exact motion during 100 cycles after the prostheses were implanted. The resulting forces, torques, and bone motions were recorded and the differences between the prostheses compared. The Hintegra and German Ankle System, significantly increased the forces and torques in relation to the specimen without a prosthesis with one exception (one-sample-t-test, each p < or = 0.01; exception, parameter lateral force measured with the German Ankle System, p = 0.34). The force, torque, and motion differences between the specimens before and after implantation of the prostheses were lower with the German Ankle System than with the Hintegra (unpaired t-test, each p < or = 0.05). The German Ankle System prosthesis had less of an effect on resulting forces and torques during partial weightbearing passive ankle motion than the Hintegra prosthesis. This might improve function and minimize loosening during the clinical use.

  17. Ferromagnetic movements of middle ear implants and stapes prostheses in a 3-T magnetic resonance field.

    PubMed

    Fritsch, Michael H; Gutt, Jason J

    2005-03-01

    A 3-T magnetic resonance field may cause motion or displacement of middle ear implants not seen in studies with 1.5-T magnets. Previous publications have described the safety limitations of some otologic implants in 1.5-T magnetic resonance fields. Several company-wide recalls of implants were issued. No studies to date have been reported for otologic implants within a 3-T magnetic resonance field, nor have there been comparisons with a 1.5-T field strength. Eighteen commonly used middle ear implants and prostheses were selected. In Part 1, the prostheses were placed in Petri dishes and exposed to a 3-T magnetic resonance field. In Part 2, the particular prostheses that showed movement in Part 1 were placed into their intended use positions within temporal bone laboratory specimens and exposed to a 3-T field. Both parts were repeated in a 1.5-T field. In Part 1, three prostheses moved dramatically from their start positions when exposed to the 3-T magnetic resonance field. In Part 2, the three particular prostheses that showed movement in Part 1 showed no gross displacement or movement from their start positions within the temporal bone laboratory specimens. No implants moved in the 1.5-T field in either Part 1 or Part 2. Certain stapes prostheses move dramatically in Petri dishes in 3-T fields. When placed into temporal bone laboratory specimens, the same prostheses show no signs of movement from the surgical site in a 3-T field, and it appears that the surgical position holds the implants firmly in place. Results of published 1.5-T field studies should not be used directly for safety recommendations in a 3-T magnetic resonance. Heat, voltage induction, and vibration during exposure to the magnetic resonance fields should be considered as additional possible safety issues. Preference should be given to platinum and titanium implants in manufacturing processes and surgical selection.

  18. In vitro evaluation of reverse torque value of abutment screw and marginal opening in a screw- and cement-retained implant fixed partial denture design.

    PubMed

    Kim, Seok-Gyu; Park, Jae-Uk; Jeong, Jae-Heon; Bae, Chang; Bae, Tae-Soo; Chee, Winston

    2009-01-01

    The purpose of this study was to evaluate the clinical efficacy of implant prostheses retained by screws and cement (SCPs) by examining the reverse torque values (RTVs) of the abutment screws and the marginal openings of the implant prostheses. Two implants (3.8 x 13 mm; Camlog Biotechnologies) were embedded in an acrylic resin block 5 mm apart. Eighteen copies of this resin specimen were fabricated and randomly divided into two groups. Two-unit implant prostheses with two different designs-purely cement-retained implant prostheses (group 1) and SCPs (group 2)-were made out of type IV gold alloy and placed on the implants. After tightening to about 30 Ncm, the preloading RTVs of the abutment screws were measured. After retightening the abutment screws or cementing the prostheses, followed by cyclic loading, the postloading RTVs of the abutment screws were examined. Also, the marginal openings of the prostheses in the two groups were measured under a stereomicroscope. These measurements were compared statistically. The postloading RTVs and their differences from the preloading RTVs of the abutment screws demonstrated no significant differences between groups (P > .05). Group 2 prostheses showed significantly smaller marginal openings than group 1 prostheses (P < .05). The forces generated when torquing the abutment screw of the SCP did not cause more loosening of the abutment screws than the purely cement-retained implant prosthesis. The SCP showed better marginal adaptation of the cement-retained part than the purely cement-retained implant prosthesis, possibly as a result of the screw-retained abutment seating the restoration. Within the limitations of this in vitro test, the SCP showed no significant difference in RTV of the abutment screw and a smaller marginal gap compared to a purely cement-retained implant prosthesis.

  19. RETURN TO RUNNING FOLLOWING A KNEE DISARTICULATION AMPUTATION: A CASE REPORT

    PubMed Central

    Diebal-Lee, Angela R.; Kuenzi, Robert S.; Rábago, Christopher A.

    2017-01-01

    Background and Purpose The evolution of running-specific prostheses has empowered athletes with lower extremity amputations to run farther and faster than previously thought possible; but running with proper mechanics is still paramount to an injury-free, active lifestyle. The purpose of this case report was to describe the successful alteration of intact limb mechanics from a Rearfoot Striking (RFS) to a Non-Rearfoot Striking (NRFS) pattern in an individual with a knee disarticulation amputation, the associated reduction in Average Vertical Loading Rate (AVLR), and the improvement in functional performance following the intervention. Case description A 30 year-old male with a traumatic right knee disarticulation amputation reported complaints of residual limb pain with running distances greater than 5 km, limiting his ability to train toward his goal of participating in triathlons. Qualitative assessment of his running mechanics revealed a RFS pattern with his intact limb and a NRFS pattern with his prosthetic limb. A full body kinematic and kinetic running analysis using 3D motion capture and force plates was performed. The average intact limb loading rate was four-times greater (112 body weights/s) than in his prosthetic limb which predisposed him to possible injury. He underwent a three week running intervention with a certified running specialist to learn a NRFS pattern with his intact limb. Outcomes Immediately following the running intervention, he was able to run distances of over 10 km without pain. On a two-mile fitness test, he decreased his run time from 19:54 min to 15:14 min. Additionally, the intact limb loading rate was dramatically reduced to 27 body weights/s, nearly identical to the prosthetic limb (24 body weights/s). Discussion This case report outlines a detailed return to run program that targets proprioceptive and neuromuscular components, injury prevention, and specificity of training strategies. The outcomes of this case report are promising as they may spur additional research toward understanding how to eliminate potential injury risk factors associated with running after limb loss. Level of Evidence 4 PMID:28900572

  20. Long-term follow-up study of bilateral above-the-knee amputees from the Vietnam War.

    PubMed

    Dougherty, P J

    1999-10-01

    Because caring for patients who have combat-related amputations is a discontinuous practice, military surgeons must relearn treatment techniques during each conflict. The purpose of the present long-term study (average duration of follow-up, 27.5 years) was to document the status of patients who had sustained a bilateral above-the-knee amputation in Vietnam and had been managed by the only separate amputee service in the United States Army. A review of the records of 484 battle amputees identified thirty individuals (6 percent) who had a bilateral above-the-knee amputation. Twenty-six (87 percent) of the thirty patients had been injured by a land mine or a booby trap. Fifty-three (88 percent) of the sixty limbs were amputated because of trauma, and the other seven (12 percent) were amputated secondarily because of infection. Data regarding education, employment, marriage and family life, prosthetic use, and psychological care were collected by mail or telephone for twenty-three (85 percent) of the twenty-seven surviving patients. Respondents also completed the Short Form-36 (SF-36) Health Survey. At the time of the study, five (22 percent) of the twenty-three respondents used prostheses for walking; the devices were used for an average of 7.7 hours per day. Sixteen respondents (70 percent) were or had been employed outside of the home since the time of discharge. The physical functioning score on the SF-36 questionnaire was significantly lower for the study group than it was for a group of age and gender-matched controls (p < 0.001; Student two-tailed t test). With the numbers available, no significant differences could be detected between the groups with regard to physical role functioning (p = 0.377), bodily pain (p = 0.603), general health (p = 0.407), vitality (p = 0.949), social functioning (p = 0.460), emotional role functioning (p = 0.029), or mental health (p = 0.102). The patients in the present study have led relatively normal, productive lives within the context of their physical limitations.

  1. Friction in hip prostheses.

    PubMed

    Hall, R M; Unsworth, A

    1997-08-01

    Although the reduction of frictional torques was the driving force behind the design of the Charnley prosthesis, later concerns about wear and subsequent loosening of this and other hip replacements have dominated debate within the bioengineering community. To stimulate discussion on the role of friction in loosening, a review of the frictional characteristics of different prostheses was undertaken. The use of simple laboratory screening-type machines in the frictional assessment of different material combinations is discussed together with experiments performed on single axis simulators using both conventional and experimental prostheses. In particular, recent developments in the use of soft layer components are highlighted. Further, the possible link between excessively high frictional torques and loosening is discussed in the light of current results obtained from explanted prostheses.

  2. The use of prostheses in skeletally immature patients.

    PubMed

    Abudu, Adesegun; Grimer, Robert; Tillman, Roger; Carter, Simon

    2006-01-01

    Prosthetic reconstruction in the skeletally immature patient is challenging because of the necessity to cope with expected disruption of limb growth after resection of one or more major growth plates and the high demands placed on implants by young patients. Although prosthetic reconstruction in children is fraught with many problems, it is usually possible to obtain a good functional limb at skeletal maturity. Extendable prostheses are readily acceptable to patients and their parents. The availability of noninvasive extendable prostheses is expected to lead to fewer complications, fewer surgical interventions, and even improved function. This article reviews the indication, evolution, and clinical and functional results of extendable endoprostheses, drawing from experience in the last 30 years of using such prostheses in children.

  3. Frequency and Type of Prosthetic Complications Associated with Interim, Immediately Loaded Full-Arch Prostheses: A 2-Year Retrospective Chart Review.

    PubMed

    Drago, Carl

    2016-08-01

    The purpose of this report was to retrospectively evaluate implant and immediate full-arch prosthesis survival rates over a 24-month period; patients were consecutively treated with immediate occlusal loading. Dental arch, gender, and implant orientation (vertical vs. tilted) were also noted. All Brånemark System implants (Nobel Active) and interim, all-acrylic resin prostheses placed in patients following an All-on-Four™ protocol, in a single private practice were assessed by retrospective patient chart review. The amount of space provided surgically for implant restorative components and prostheses was determined from measurements of the vertical heights of the interim prostheses in the right/left anterior and posterior segments. These measurements were made in the laboratory. Interim prosthetic repairs (type, frequency, length of time from insertion) were analyzed by type, arch, gender, and implant orientation. Implant survival and insertion torque values were also measured. Inclusion criteria consisted of all Brånemark System implants placed with the All-on-Four protocol from September 1, 2011, until August 31, 2013. Specific dietary instructions were given for the first 7 days immediately postoperatively and for the weeks prior to insertion of the definitive prostheses. One hundred twenty-nine patients, comprising 191 arches (766 implants) from September 1, 2011, until August 31, 2013, were included in the study. One patient experienced implant failure yielding an overall implant survival rate (SR) of 99.5% (762 of 766). Four hundred twenty-six of 430 maxillary implants and 336 of 336 mandibular implants survived for SRs of 99.1% and 100%, respectively. Regarding implant orientation, 415 of 417 tilted implants (SR 99.5%) and 343 of 345 (CSR 95.6%) vertical implants were noted to be clinically stable. Interim, all-acrylic resin prostheses were in place for a mean of 199.2 days; mandibular prostheses were in place for an average of 195.4 days; maxillary prostheses were in place for an average of 202.0 days. Thirty four of the 191 interim prostheses (17.8%) warranted at least one repair during the treatment period. The average overall implant insertion torque value was 60.74 Ncm; mandibular torque values averaged 63.08 Ncm; maxillary torque values averaged 59.00 Ncm. The results from this study suggest that dental arch, gender, and implant orientation for implants placed and immediately restored with interim, all-acrylic resin, full-arch prostheses per the All-on-Four protocol did not have significant statistical or clinical effects on prosthetic complications of the interim prostheses or implant survival. Only one of the 129 patients experienced implant failures, indicating that the All-on-Four treatment protocol used in this study is a viable alternative to other protocols for rehabilitating edentulous patients. © 2015 by the American College of Prosthodontists.

  4. The influence of intraoperative soft tissue balance on patellar pressure in posterior-stabilized total knee arthroplasty.

    PubMed

    Matsumoto, Tomoyuki; Shibanuma, Nao; Takayama, Koji; Sasaki, Hiroshi; Ishida, Kazunari; Matsushita, Takehiko; Kuroda, Ryosuke; Kurosaka, Masahiro

    2016-06-01

    Appropriate soft tissue balance is essential for the success of total knee arthroplasty (TKA), and assessment with an offset-type tensor provides useful information about the femorotibial (FT) joint. The purpose of the study was to investigate the relationship between intraoperative soft tissue balance and patellar pressure at both medial and lateral sides. Thirty varus-type osteoarthritis patients who received mobile-bearing posterior-stabilized TKAs were enrolled in the study. Using the tensor, soft tissue balance, including joint component gap and varus ligament balance, was recorded at 0°, 10°, 30°, 60°, 90°, 120°, and 135° with patellofemoral (PF) joint reduction and femoral component placement. Following final prostheses implanted with appropriate insert, the medial and lateral patellar pressures were measured at each flexion angle. A simple regression analysis was performed between each patellar pressure, parameter of soft tissue balance, and postoperative flexion angle. Both lateral and medial patellar pressures increased with flexion. The lateral patellar pressure was significantly higher than the medial patellar pressure at 60°, 90°, and 135° of flexion (p<0.05). The lateral patellar pressure inversely correlated with the varus ligament balance at 60° and 90° of flexion (p<0.05). The lateral patellar pressure at 120° and 135° of flexion inversely correlated with the postoperative flexion angle (p<0.05). Soft tissue balance influenced patellar pressure. In particular, a reduced lateral patellar pressure was found at the lateral laxity at flexion, leading to high postoperative flexion angle. III. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. No Differences Identified in Transverse Plane Biomechanics Between Medial Pivot and Rotating Platform Total Knee Implant Designs.

    PubMed

    Papagiannis, Georgios I; Roumpelakis, Ilias M; Triantafyllou, Athanasios I; Makris, Ioannis N; Babis, George C

    2016-08-01

    Total knee arthroplasties (TKAs) using well-designed, fixed bearing prostheses, such as medial pivot (MP), have produced good long-term results. Rotating-platform, posterior-stabilized (RP-PS) mobile bearing implants were designed to decrease polyethylene wear. Sagittal and coronal plane TKA biomechanics are well examined and correlated to polyethylene wear. However, limited research findings describe this relationship in transverse plane. We assumed that although axial plane biomechanics might not be the most destructive parameters on polyethylene wear, it is important to clarify their role because both joint kinematics and kinetics in all 3 planes are important input parameters for TKA wear testing (International Organization for Standardization 14243-1 and 14343-3). Our hypothesis was that transverse plane overall range of motion (ROM) and/or peak moment show differences that reflect on wear advantages when compared RP-PS implants to MP designs. Two groups (MPs = 24 and RP-PSs = 22 subjects) were examined by using 3D gait analysis. The variables were total internal-external rotation (IER) ROM and peak IER moments. No statistically significant difference was demonstrated between the 2 groups in kinetics (P = .389) or kinematics (P = .275). In the present study, no wear advantages were found between 2 TKAs. Both designs showed identical kinetics at the transverse plane in level-ground walking. Kinematic analysis could not illustrate any statistically significant difference in terms of overall IER ROM. Nevertheless, kinematic gait pattern differences observed possibly reflect different patterns of joint surface motion or abnormal gait patterns. Thus, wear testing with various input waveforms combined with functional data analysis will be necessary to identify the actual effects of gait variability on polyethylene wear. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Flexion and extension gaps created by the navigation-assisted gap technique show small acceptable mismatches and close mutual correlations.

    PubMed

    Lee, Dae-Hee; Shin, Young-Soo; Jeon, Jin-Ho; Suh, Dong-Won; Han, Seung-Beom

    2014-08-01

    The aim of this study was to investigate the mechanism underlying the development of gap differences in total knee arthroplasty using the navigation-assisted gap technique and to assess whether these gap differences have statistical significance. Ninety-two patients (105 knees) implanted with cruciate-retaining prostheses using the navigation-assisted gap balancing technique were prospectively analysed. Medial extension and flexion gaps and lateral extension and flexion gaps were measured at full extension and at 90° of flexion. Repeated measures analysis of variance was used to compare the mean values of these four gaps. The correlation coefficient between each pair of gaps was assessed using Pearson's correlation analysis. Mean intra-operative medial and lateral extension gaps were 20.6 ± 2.1 and 21.7 ± 2.2 mm, respectively, and mean intra-operative medial and lateral flexion gaps were 21.6 ± 2.7 and 22.1 ± 2.5 mm, respectively. The pairs of gaps differed significantly (P < 0.05 each), except for the difference between the medial flexion and lateral extension gaps (n.s.). All four gaps were significantly correlated with each other, with the highest correlation between the medial and lateral flexion gaps (r = 0.890, P < 0.001) and the lowest between the medial flexion and lateral extension gaps (r = 0.701, P < 0.001). Medial and lateral flexion and extension gaps created using the navigation-assisted gap technique differed significantly, although the differences between them were <2 mm, and the gaps were closely correlated. These narrow ranges of statistically acceptable gap differences and the strong correlations between gaps should be considered by surgeons, as should the risks of soft tissue over-release or unintentional increases in extension or flexion gap after preparation of the other gap.

  7. The quality of life analysis of knee prosthesis with complete microprocessor control in trans-femoral amputees.

    PubMed

    Saglam, Yavuz; Gulenc, Baris; Birisik, Fevzi; Ersen, Ali; Yilmaz Yalcinkaya, Ebru; Yazicioglu, Onder

    2017-12-01

    The aim of this study was to analyze the patient demographics, etiology of limb loss as well as reporting SF-36 scores for microprocessor prosthesis users in Turkish population. We reviewed 72 patients (61 male and 11 female; mean age: 37.7 ± 10.7) with uni-lateral, above knee amputation and a history of regular and microprocessor prosthesis use. All patients were called back for a last follow-up and they were asked to fill a self-administered general health status questionnaire (SF-36). According to the SF-36 results; physical component score (PCS) score was 46 ± 7.3 and mental components summary (MCS) score was 46.5 ± 9.1. These scores have statistical similarity with Turkish healthy controls, except SF (social functioning) sub-dimension. PCS score for women microprocessor users were significantly lower than men (43.3 vs. 48.7, p = 0.03), but MCS scores were similar in between genders (46 vs. 48.2, p = 0.13). Conventional prostheses usage time was positively correlated with physical function (PF) scores (r = 0.322, p = 0.010). Microprocessor prosthesis usage time was negatively correlated with role limitations due to emotional problem (RE) scores (r = -0,313, p = 0.009). The quality of life surveys were showed that the loss of an extremity have higher physical and psychological impact on women's physical scores. Overall, SF-36 results were similar in microprocessor using amputee's and Turkish normal controls. Level IV, therapeutic study. Copyright © 2017 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  8. Outcome of Acute Prosthetic Joint Infections Due to Gram-Negative Bacilli Treated with Open Debridement and Retention of the Prosthesis▿

    PubMed Central

    Martínez-Pastor, Juan C.; Muñoz-Mahamud, Ernesto; Vilchez, Félix; García-Ramiro, Sebastián; Bori, Guillem; Sierra, Josep; Martínez, José A.; Font, Lluis; Mensa, Josep; Soriano, Alex

    2009-01-01

    The aim of our study was to evaluate the outcome of acute prosthetic joint infections (PJIs) due to gram-negative bacilli (GNB) treated without implant removal. Patients with an acute PJI due to GNB diagnosed from 2000 to 2007 were prospectively registered. Demographics, comorbidity, type of implant, microbiology data, surgical treatment, antimicrobial therapy, and outcome were recorded. Classification and regression tree analysis, the Kaplan-Meier survival method, and the Cox regression model were applied. Forty-seven patients were included. The mean age was 70.7 years, and there were 15 hip prostheses and 32 knee prostheses. The median number of days from the time of arthroplasty was 20. The most frequent pathogens were members of the Enterobacteriaceae family in 41 cases and Pseudomonas spp. in 20 cases. Among the Enterobacteriaceae, 14 were resistant to ciprofloxacin, while all Pseudomonas aeruginosa isolates were susceptible to ciprofloxacin. The median durations of intravenous and oral antibiotic treatment were 14 and 64 days, respectively. A total of 35 (74.5%) patients were in remission after a median follow-up of 463 days (interquartile range, 344 to 704) days. By use of the Kaplan-Meier survival curve, a C-reactive protein (CRP) concentration of ≤15 mg/dl (P = 0.03) and receipt of a fluoroquinolone, when all GNB isolated were susceptible (P = 0.0009), were associated with a better outcome. By use of a Cox regression model, a CRP concentration of ≤15 mg/dl (odds ratio [OR], 3.57; 95% confidence interval [CI], 1.05 to 12.5; P = 0.043) and receipt of a fluoroquinolone (OR, 9.09; 95% CI, 1.96 to 50; P = 0.005) were independently associated with better outcomes. Open debridement without removal of the implant had a success rate of 74.5%, and the factors associated with good prognosis were a CRP concentration at the time of diagnosis ≤15 mg/dl and treatment with a fluoroquinolone. PMID:19687237

  9. Outcome of acute prosthetic joint infections due to gram-negative bacilli treated with open debridement and retention of the prosthesis.

    PubMed

    Martínez-Pastor, Juan C; Muñoz-Mahamud, Ernesto; Vilchez, Félix; García-Ramiro, Sebastián; Bori, Guillem; Sierra, Josep; Martínez, José A; Font, Lluis; Mensa, Josep; Soriano, Alex

    2009-11-01

    The aim of our study was to evaluate the outcome of acute prosthetic joint infections (PJIs) due to gram-negative bacilli (GNB) treated without implant removal. Patients with an acute PJI due to GNB diagnosed from 2000 to 2007 were prospectively registered. Demographics, comorbidity, type of implant, microbiology data, surgical treatment, antimicrobial therapy, and outcome were recorded. Classification and regression tree analysis, the Kaplan-Meier survival method, and the Cox regression model were applied. Forty-seven patients were included. The mean age was 70.7 years, and there were 15 hip prostheses and 32 knee prostheses. The median number of days from the time of arthroplasty was 20. The most frequent pathogens were members of the Enterobacteriaceae family in 41 cases and Pseudomonas spp. in 20 cases. Among the Enterobacteriaceae, 14 were resistant to ciprofloxacin, while all Pseudomonas aeruginosa isolates were susceptible to ciprofloxacin. The median durations of intravenous and oral antibiotic treatment were 14 and 64 days, respectively. A total of 35 (74.5%) patients were in remission after a median follow-up of 463 days (interquartile range, 344 to 704) days. By use of the Kaplan-Meier survival curve, a C-reactive protein (CRP) concentration of < or = 15 mg/dl (P = 0.03) and receipt of a fluoroquinolone, when all GNB isolated were susceptible (P = 0.0009), were associated with a better outcome. By use of a Cox regression model, a CRP concentration of < or = 15 mg/dl (odds ratio [OR], 3.57; 95% confidence interval [CI], 1.05 to 12.5; P = 0.043) and receipt of a fluoroquinolone (OR, 9.09; 95% CI, 1.96 to 50; P = 0.005) were independently associated with better outcomes. Open debridement without removal of the implant had a success rate of 74.5%, and the factors associated with good prognosis were a CRP concentration at the time of diagnosis < or = 15 mg/dl and treatment with a fluoroquinolone.

  10. Clinical and Radiographic Assessment of Reasons for Replacement of Metal- Ceramic Fixed Dental Prostheses in Patients Referring to Dental School.

    PubMed

    Al Refai, Roa'a; Saker, Samah

    2018-01-01

    The expected length of service and reasons for fixed dental prostheses (FDPs) replacement are a frequent inquiry by patients while the answers were mainly based on studies reports that was conducted outside the middle east region. This clinical and radiographic survey was constructed to assess and survey clinically and radiographically the reasons of replacement of metal-ceramic fixed dental prostheses, amongst patients reporting at dental school in Taibah University. Between January and May 2016, 151 patients were recruited for this study. Interview (include questions pertained to the length of service of the prosthesis, the nature of complaint as told by patient in her own words), clinical examination, intra-oral photographs, and periapical radiographs, were done by the researchers. The parameters assessed were secondary caries, open margins, loss of retention, failure of endodontic treatment of the abutment and periodontal diseases. A total number of 249 failed fixed dental prostheses were evaluated. Of which 180 (39.7%) were single crowns, 159 (35.0%) were retainers and 117 (25.8%) were pontics in 69 fixed partial denture. The most common reason for replacement of fixed restorations was periodontal diseases affecting 92.8% of all types' restorations, followed by defective margin in 90.4% of examined restoration, poor aesthetic in 88% of restorations, while periapical involvement was found in 85.5% of fixed dental prosthesis. The survival rates of fixed prostheses were not predictable, and no association was found between number of years in service and the number of restorations. The most common reasons for replacing single unit fixed dental prostheses are periodontal diseases and periapical involvement, while defective margins and poor aesthetic mainly associated with multi-unit fixed dental prostheses. Key words: Failure, Fixed dental prosthesis, Survival, Replacement.

  11. What are estimated reimbursements for lower extremity prostheses capable of surgical and nonsurgical lengthening?

    PubMed

    Henderson, Eric R; Pepper, Andrew M; Letson, G Douglas

    2012-04-01

    Growing prostheses accommodate skeletally immature patients with bone tumors undergoing limb-preserving surgery. Early devices required surgical procedures for lengthening; recent devices lengthen without surgery. Expenses for newer expandable devices that lengthen without surgery are more than for their predecessors but overall reimbursement amounts are not known. We sought to determine reimbursement amounts associated with lengthening of growing prostheses requiring surgical and nonsurgical lengthening. We retrospectively reviewed 17 patients with growing prostheses requiring surgical expansion and eight patients with prostheses capable of nonsurgical expansion. Insurance documents were reviewed to determine the reimbursement for implantation, lengthening, and complications. Growth data were obtained from the literature. Mean reimbursement amounts of surgical and nonsurgical lengthenings were $9950 and $272, respectively. Estimated reimbursements associated with implantation of a growing prosthesis varied depending on age, sex, and location. The largest difference was found for 4-year-old boys with distal femoral replacement where reimbursement for expansion to maturity for surgical and nonsurgical lengthening prostheses would be $379,000 and $208,000, respectively. For children requiring more than one surgical expansion, net reimbursements were lower when a noninvasive lengthening device was used. Annual per-prosthesis maintenance reimbursements to address complications for surgical and nonsurgical lengthening prostheses were $3386 and $1856, respectively. This study showed that reimbursements for lengthening of growing endoprostheses capable of nonsurgical expansion may be less expensive in younger patients, particularly male patients undergoing distal femur replacement, than endoprostheses requiring surgical lengthening. Longer outcomes studies are required to see if reimbursements for complications differ between devices. Level III, economic and decision analysis. See the Guidelines for Authors for a complete description of levels of evidence.

  12. Prosthesis use in adult acquired major upper-limb amputees: patterns of wear, prosthetic skills and the actual use of prostheses in activities of daily life.

    PubMed

    Østlie, Kristin; Lesjø, Ingrid Marie; Franklin, Rosemary Joy; Garfelt, Beate; Skjeldal, Ola Hunsbeth; Magnus, Per

    2012-11-01

    To describe patterns of prosthesis wear and perceived prosthetic usefulness in adult acquired upper-limb amputees (ULAs). To describe prosthetic skills in activities of daily life (ADL) and the actual use of prostheses in the performance of ADL tasks. To estimate the influence of prosthetic skills on actual prosthesis use and the influence of background factors on prosthetic skills and actual prosthesis use. Cross-sectional study analysing population-based questionnaire data (n = 224) and data from interviews and clinical testing in a referred/convenience sample of prosthesis-wearing ULAs (n = 50). Effects were analysed using linear regression. 80.8% wore prostheses. 90.3% reported their most worn prosthesis as useful. Prosthetic usefulness profiles varied with prosthetic type. Despite demonstrating good prosthetic skills, the amputees reported actual prosthesis use in only about half of the ADL tasks performed in everyday life. In unilateral amputees, increased actual use was associated with sufficient prosthetic training and with the use of myoelectric vs cosmetic prostheses, regardless of amputation level. Prosthetic skills did not affect actual prosthesis use. No background factors showed significant effect on prosthetic skills. Most major ULAs wear prostheses. Individualised prosthetic training and fitting of myoelectric rather than passive prostheses may increase actual prosthesis use in ADL.

  13. Spectral components in electromyograms from four regions of the human masseter, in natural dentate and edentulous subjects with removable prostheses and implants.

    PubMed

    Guzmán-Venegas, Rodrigo A; Palma, Felipe H; Biotti P, Jorge L; de la Rosa, Francisco J Berral

    2018-06-01

    To compare the frequency or spectral components between different regions of the superficial masseter in young natural dentate and total edentulous older adults rehabilitated with removable prostheses and fixed-implant support. A secondary objective was to compare these components between the three groups. 21 young natural dentate and 28 edentulous (14 with removable prostheses and 14 with fixed-implant support) were assessed. High-density surface electromyography (sEMG) was recorded in four portions of the superficial masseter during submaximal isometric bites. Spectral components were obtained through a spectral analysis of the sEMG signals. An analysis of mixed models was used to compare the spectral components. In all groups, the spectral components of the anterior portion were lower than in the posterior region (p < 0.05). Both edentulous groups showed lower spectral components and median frequency slope than the natural dentate group (p < 0.05). The removable prostheses group showed the greatest differences with natural dentate group. There were significant differences in the spectral components recorded in the different regions of the superficial masseter. The lower spectral components and fatigability of older adults rehabilitated with prostheses could be a cause of a greater loss of type II fibers, especially in the removable prostheses group. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Experimental and Monte Carlo evaluation of Eclipse treatment planning system for effects on dose distribution of the hip prostheses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Çatlı, Serap, E-mail: serapcatli@hotmail.com; Tanır, Güneş

    2013-10-01

    The present study aimed to investigate the effects of titanium, titanium alloy, and stainless steel hip prostheses on dose distribution based on the Monte Carlo simulation method, as well as the accuracy of the Eclipse treatment planning system (TPS) at 6 and 18 MV photon energies. In the present study the pencil beam convolution (PBC) method implemented in the Eclipse TPS was compared to the Monte Carlo method and ionization chamber measurements. The present findings show that if high-Z material is used in prosthesis, large dose changes can occur due to scattering. The variance in dose observed in the presentmore » study was dependent on material type, density, and atomic number, as well as photon energy; as photon energy increased back scattering decreased. The dose perturbation effect of hip prostheses was significant and could not be predicted accurately by the PBC method for hip prostheses. The findings show that for accurate dose calculation the Monte Carlo-based TPS should be used in patients with hip prostheses.« less

  15. 21 CFR 888.6 - Degree of constraint.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... ORTHOPEDIC DEVICES General Provisions § 888.6 Degree of constraint. Certain joint prostheses provide more... affecting the safety and effectiveness of orthopedic prostheses. FDA is defining the following standard...

  16. 21 CFR 888.6 - Degree of constraint.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... ORTHOPEDIC DEVICES General Provisions § 888.6 Degree of constraint. Certain joint prostheses provide more... affecting the safety and effectiveness of orthopedic prostheses. FDA is defining the following standard...

  17. 21 CFR 888.6 - Degree of constraint.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... ORTHOPEDIC DEVICES General Provisions § 888.6 Degree of constraint. Certain joint prostheses provide more... affecting the safety and effectiveness of orthopedic prostheses. FDA is defining the following standard...

  18. 21 CFR 888.6 - Degree of constraint.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... ORTHOPEDIC DEVICES General Provisions § 888.6 Degree of constraint. Certain joint prostheses provide more... affecting the safety and effectiveness of orthopedic prostheses. FDA is defining the following standard...

  19. Results after mitral valve replacement with cloth-covered Starr-Edwards prostheses (models 6300, 6310/6320, and 6400).

    PubMed Central

    Forman, R; Beck, W; Barnard, C N

    1978-01-01

    The actuarial survival and thromboembolic rates for the three types of cloth-covered Starr-Edwards mitral prostheses, models 6300, 6310/6320, and 6400 followed 6, 5, and 2 years, respectively, were not significantly different throughout the years they were followed. The combined cumulative survival and thromboembolic proportion at 5 years for these prostheses were 71 and 66 per cent, respectively. The thromboembolic rates were not different in the following two groups: (a) 238 patients receiving anticoagulants, and (b) 52 patients who had discontinued or who were not receiving anticoagulants. Four patients thrombosed their mitral prostheses. Another 8 per cent had class 3 symptoms after operation, which were attributed to myopathic or restrictive left ventricular dysfunction or other valvular disease. PMID:656234

  20. [Design and optimization of wireless power and data transmission for visual prosthesis].

    PubMed

    Lei, Xuping; Wu, Kaijie; Zhao, Lei; Chai, Xinyu

    2013-11-01

    Boosting spatial resolution of visual prostheses is an effective method to improve implant subjects' visual perception. However, power consumption of visual implants greatly rises with the increasing number of implanted electrodes. In respond to this trend, visual prostheses need to develop high-efficiency wireless power transmission and high-speed data transmission. This paper presents a review of current research progress on wireless power and data transmission for visual prostheses, analyzes relative principles and requirement, and introduces design methods of power and data transmission.

  1. Progress in the clinical development and utilization of vision prostheses: an update

    PubMed Central

    Brandli, Alice; Luu, Chi D; Guymer, Robyn H; Ayton, Lauren N

    2016-01-01

    Vision prostheses, or “bionic eyes”, are implantable medical bionic devices with the potential to restore rudimentary sight to people with profound vision loss or blindness. In the past two decades, this field has rapidly progressed, and there are now two commercially available retinal prostheses in the US and Europe, and a number of next-generation devices in development. This review provides an update on the development of these devices and a discussion on the future directions for the field. PMID:28539798

  2. Usefulness of magnetic resonance imaging in the postsurgical assessment of patients with inflatable penile prostheses.

    PubMed

    Pacheco Usmayo, A; Torregrosa Andrés, A; Flores Méndez, J; Luján Marco, S; Rogel Bertó, R

    To describe the types of penile prostheses and their components, to review the appropriate magnetic resonance imaging (MRI) acquisition protocol, and to describe the normal imaging findings and possible complications in patients with inflatable penile implants. Three-piece inflatable penile prostheses are the last link in the treatment chain for erectile dysfunction. They can develop complications, which are classified as non-infectious related to the surgical technique, infectious, or due to mechanical failure of the device. MRI is the most appropriate imaging technique for the postsurgical evaluation of penile prostheses. Images are acquired in three planes using sequences with high spatial resolution, first with the prosthesis at rest and then with the prosthesis activated. Copyright © 2017 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. Appearance of low signal intensity lines in MRI of silicone breast implants.

    PubMed

    Stroman, P W; Rolland, C; Dufour, M; Grondin, P; Guidoin, R G

    1996-05-01

    Magnetic resonance (MR) images of five explanted mammary prostheses were obtained with a 1.5 T GE Signa system using a conventional spin-echo pulse sequence, in order to investigate the low-intensity curvilinear lines which may be observed in MR images of silicone gel-filled breast implants under pressure from fibrous capsules. MR images showed ellipsoid prostheses, often containing multiple low-intensity curvilinear lines which in some cases presented an appearance very similar to that of the linguine sign. Upon opening the fibrous capsules, however, all of the prostheses were found to be completely intact demonstrating that the appearance of multiple low signal intensity curvilinear lines in MR images of silicone gel-filled prostheses is not necessarily a sign of prosthesis rupture. The MR image features which are specific to the linguine sign must be more precisely defined.

  4. ["Bionic" arm prostheses. State of the art in research and development].

    PubMed

    Pylatiuk, C; Döderlein, L

    2006-11-01

    A new generation of arm prostheses is being developed worldwide. These so-called bionic prostheses are intended to offer additional functions, such as sensory feedback, extended range of possible movement, intuitive movement control as far as possible, and a more natural cosmetic appearance. In recent years, prosthetic components with much enhanced performance have been developed for use at various levels of the upper limb. Artificial hands that allow for additional grips are are being tested in clinical settings. Innovative methods of signal acquisition and communication with the patient are being intensively researched. Several patients have been provided with prototypes of new arm prostheses. At the moment, the results are limited by the restricted communication between patient and prosthesis. However, we can expect the options for prosthesis control to be extended in the near future.

  5. A Three-Dimensional Finite Element Analysis of the Stress Distribution Generated by Splinted and Nonsplinted Prostheses in the Rehabilitation of Various Bony Ridges with Regular or Short Morse Taper Implants.

    PubMed

    Toniollo, Marcelo Bighetti; Macedo, Ana Paula; Rodrigues, Renata Cristina; Ribeiro, Ricardo Faria; de Mattos, Maria G

    The aim of this study was to compare the biomechanical performance of splinted or nonsplinted prostheses over short- or regular-length Morse taper implants (5 mm and 11 mm, respectively) in the posterior area of the mandible using finite element analysis. Three-dimensional geometric models of regular implants (Ø 4 × 11 mm) and short implants (Ø 4 × 5 mm) were placed into a simulated model of the left posterior mandible that included the first premolar tooth; all teeth posterior to this tooth had been removed. The four experimental groups were as follows: regular group SP (three regular implants were rehabilitated with splinted prostheses), regular group NSP (three regular implants were rehabilitated with nonsplinted prostheses), short group SP (three short implants were rehabilitated with splinted prostheses), and short group NSP (three short implants were rehabilitated with nonsplinted prostheses). Oblique forces were simulated in molars (365 N) and premolars (200 N). Qualitative and quantitative analyses of the minimum principal stress in bone were performed using ANSYS Workbench software, version 10.0. The use of splinting in the short group reduced the stress to the bone surrounding the implants and tooth. The use of NSP or SP in the regular group resulted in similar stresses. The best indication when there are short implants is to use SP. Use of NSP is feasible only when regular implants are present.

  6. Estimation of appropriate lubricating film thickness in ceramic-on-ceramic hip prostheses

    NASA Astrophysics Data System (ADS)

    Tauviqirrahman, M.; Muchammad, Bayuseno, A. P.; Ismail, R.; Saputra, E.; Jamari, J.

    2016-04-01

    Artificial hip prostheses, consisting of femoral head and acetabular cup are widely used and have affected the lives of many people.However, the primary issue associated with the long term performance of hip prostheses is loosening induced by excessive wear during daily activity. Therefore, an effective lubrication is necessary to significantly decrease the wear. To help understand the lubricating performance of such typical hip joint prostheses, in the present paper a hydrodynamic lubrication model based on Reynolds equationwas introduced. The material pairs of ceramic acetabular cup against ceramic femoral head was investegated.The main aim of this study is to investigate of the effect of loading on the formation of lubricating film thickness.The model of a ball-in-socket configuration was considered assuming that the cup was stationary while the ball was to rotate at a steady angular velocityvarying loads.Based on simulation result, it was found that to promote fluid film lubrication and prevent the contacting components leading to wear, the film thickness of lubricant should be determined carefully based on the load applied. This finding may have useful implication in predicting the failure of lubricating synovial fluid film and wear generation in hip prostheses.

  7. Incus replacement prostheses of hydroxylapatite in middle ear reconstruction.

    PubMed

    Wehrs, R E

    1989-05-01

    Hydroxylapatite is a calcium bioceramic that has the same chemical composition as living bone, Ca10 (PO4) 6 (OH) 2. Since 1970 it has been used as a material in reconstructive prostheses and augmentation of lost tissues in various surgical specialties including maxillofacial surgery, plastic surgery, otolaryngology, and orthopedics. For over 20 years the author has used autograft and homograft ossicles in tympanoplasty. These incudi have been modified into prostheses that were utilized in ossicular reconstruction. During this time two principle prostheses have evolved, the notched incus with short and long processes. The short process prosthesis is used with an intact stapes, whereas the notched incus with long process carries the sound pressure directly to the stapedial footplate. These prostheses have been successful in improving and maintaining hearing following tympanoplasty. Unfortunately, however, the use of human tissue has certain limitations: it is not readily accessible and has a limited shelf life. Furthermore, clinicians are wary of using homograft tissue as concern over the AIDS virus spreads. Therefore it was felt prudent to develop a manmade prosthesis that would as nearly as possible match the advantages of living bone. Hydroxylapetite most nearly met those qualifications.

  8. Prototyping for surgical and prosthetic treatment.

    PubMed

    Goiato, Marcelo Coelho; Santos, Murillo Rezende; Pesqueira, Aldiéris Alves; Moreno, Amália; dos Santos, Daniela Micheline; Haddad, Marcela Filié

    2011-05-01

    Techniques of rapid prototyping were introduced in the 1980s in the field of engineering for the fabrication of a solid model based on a computed file. After its introduction in the biomedical field, several applications were raised for the fabrication of models to ease surgical planning and simulation in implantology, neurosurgery, and orthopedics, as well as for the fabrication of maxillofacial prostheses. Hence, the literature has described the evolution of rapid prototyping technique in health care, which allowed easier technique, improved surgical results, and fabrication of maxillofacial prostheses. Accordingly, a literature review on MEDLINE (PubMed) database was conducted using the keywords rapid prototyping, surgical planning, and maxillofacial prostheses and based on articles published from 1981 to 2010. After reading the titles and abstracts of the articles, 50 studies were selected owing to their correlations with the aim of the current study. Several studies show that the prototypes have been used in different dental-medical areas such as maxillofacial and craniofacial surgery; implantology; neurosurgery; orthopedics; scaffolds of ceramic, polymeric, and metallic materials; and fabrication of personalized maxillofacial prostheses. Therefore, prototyping has been an indispensable tool in several studies and helpful for surgical planning and fabrication of prostheses and implants.

  9. Exploiting arm posture synergies in activities of daily living to control the wrist rotation in upper limb prostheses: A feasibility study.

    PubMed

    Montagnani, Federico; Controzzi, Marco; Cipriani, Christian

    2015-01-01

    Although significant technological advances have been made in the last forty years, natural and effortless control of upper limb prostheses is still an open issue. Commercially available myoelectric prostheses present limited Degrees of Freedom (DoF) mainly because of the lack of available and reliable independent control signals from the human body. Thus, despite the crucial role that an actuated wrist could play in a transradial prosthesis in terms of avoiding compensatory movements, commercial hand prostheses present only manually adjustable passive wrists or actuated rotators controlled by (unnatural) sequential control strategies. In the present study we investigated the synergies between the humeral orientation with respect to the trunk and the forearm pronation/supination angles during the execution of a wide range of activities of daily living, in healthy subjects. Our results showed consistent postural synergies between the two selected body segments for almost the totality of the activities of daily living under investigation. This is a promising result because these postural synergies could be exploited to automatically control the wrist rotator unit in transradial prostheses improving the fluency and the dexterity of the amputee.

  10. Prostheses and orthoses in the collections of the Auschwitz-Birkenau State Museum.

    PubMed

    Przeździak, Bogumił; Lutomirski, Adam; Kulczyk, Maria

    2011-01-01

    The authors described 424 orthopaedic appliances left by the prisoners of the Nazi Concentration Camp in Oświęcim. A collection of prostheses and orthoses, which is currently a part of the Auschwitz-Birkenau State Museum's exhibition, is extraordinary as it illustrates the fate of innocent, crippled people, who were incarcerated and murdered. Another point of value of the collection is its technical aspect, as it provides a clear picture of construction of prostheses and orthoses at the beginning of the 20th century.

  11. Biodeterioration of medical-grade silicone rubber used for voice prostheses: a SEM study.

    PubMed

    Neu, T R; Van der Mei, H C; Busscher, H J; Dijk, F; Verkerke, G J

    1993-05-01

    Silicone voice prostheses used for rehabilitation of speech after total laryngectomy are inserted in an non-sterile habitat. Deposits on explanted Groningen Button voice prostheses revealed a biofilm, due to heavy colonization of the silicone surface by bacteria and yeasts. Furthermore, it was demonstrated by scanning electron microscopy on sectioned explants that the silicone material was deteriorated by filamentous and vegetative yeast cells. The different explants showed a variety of sharp-edged, discrete yeast colonies. The yeasts grew just under the silicone surface and up to 700 microns into the silicone material. Finally, nine different types of defects in the silicone material created by the yeasts are described. This deterioration of the silicone by yeasts seems to be the main reason for the failure and the frequent replacement of the prostheses. The mechanisms of silicone deterioration are still hypothetical.

  12. Trends in Computer-Aided Manufacturing in Prosthodontics: A Review of the Available Streams

    PubMed Central

    Bennamoun, Mohammed

    2014-01-01

    In prosthodontics, conventional methods of fabrication of oral and facial prostheses have been considered the gold standard for many years. The development of computer-aided manufacturing and the medical application of this industrial technology have provided an alternative way of fabricating oral and facial prostheses. This narrative review aims to evaluate the different streams of computer-aided manufacturing in prosthodontics. To date, there are two streams: the subtractive and the additive approaches. The differences reside in the processing protocols, materials used, and their respective accuracy. In general, there is a tendency for the subtractive method to provide more homogeneous objects with acceptable accuracy that may be more suitable for the production of intraoral prostheses where high occlusal forces are anticipated. Additive manufacturing methods have the ability to produce large workpieces with significant surface variation and competitive accuracy. Such advantages make them ideal for the fabrication of facial prostheses. PMID:24817888

  13. [An experimental study of the coagulating properties of a laser beam applied to fix titanium prostheses of auditory ossicles with the use of platelet-rich plasma].

    PubMed

    Semenov, V F; Semenov, F V

    2013-01-01

    The displacement of prostheses of auditory ossicles at the concluding stage of surgery and in the early postoperative period is one of the factors influencing the functional outcome of stapedoplasty. The objective of the present experimental study was to estimate the effectiveness of the use of platelet-rich plasma as an alloy for the laser welding in order to improve fixation of titanium prostheses employed in ossiculoplastic surgery. The results of a series of experiments undertaken to assess the possibility of stabilization of titanium prostheses in the desired position with the help of laser welding indicate that this technique with the use of platelet-rich plasma as an alloy may be a reliable method for the fixation of the reconstructed chain of ossicles in the desired position.

  14. Implant-retained craniofacial prostheses for facial defects

    PubMed Central

    Federspil, Philipp A.

    2012-01-01

    Craniofacial prostheses, also known as epistheses, are artificial substitutes for facial defects. The breakthrough for rehabilitation of facial defects with implant-retained prostheses came with the development of the modern silicones and bone anchorage. Following the discovery of the osseointegration of titanium in the 1950s, dental implants have been made of titanium in the 1960s. In 1977, the first extraoral titanium implant was inserted in a patient. Later, various solitary extraoral implant systems were developed. Grouped implant systems have also been developed which may be placed more reliably in areas with low bone presentation, as in the nasal and orbital region, or the ideally pneumatised mastoid process. Today, even large facial prostheses may be securely retained. The classical atraumatic surgical technique has remained an unchanged prerequisite for successful implantation of any system. This review outlines the basic principles of osseointegration as well as the main features of extraoral implantology. PMID:22073096

  15. [In situ aortofemoral reconstructions in surgical treatment of infected aortofemoral grafts].

    PubMed

    Badretdinov, I A; Pokrovsky, A V

    2015-01-01

    The article presents a review of literature sources covering possibilities of peiforming in situ aortofemoral reconstructions in surgical treatment of infected aortofemoral grafts. This methodology makes it possible to improve the outcomes of treatment for paraprosthetic infection at the expense of decreasing lethality and morbidity, increasing parameters of patency of grafts and lower limb salvage in the remote postoperative period. Mention should be made that in situ secondary aortofemoral reconstructions are fraught with danger of relapsing paraprosthetic infection, therefore many publications are dedicated to search for prostheses most resistant to infection. The article also presents the results of works devoted to the use of various types of prostheses for in situ secondary aortofemoral reconstructions: prostheses made of polytetrafluoroethylene (PTFE), synthetic grafts saturated with various antibacterial drugs and gelatine, cadaveric allografts, synthetic prostheses treated with silver ions, autovenous conduits based on the femoral and popliteal veins.

  16. Reflections on the present and future of upper limb prostheses.

    PubMed

    Farina, Dario; Amsüss, Sebastian

    2016-01-01

    Despite progress in research and media attention on active upper limb prostheses, presently the most common commercial upper limb prosthetic devices are not fundamentally different from solutions offered almost one century ago. Limited information transfer for both control and sensory-motor integration and challenges in socket technology have been major obstacles. By analysing the present state-of-the-art and academic achievements, we provide our opinion on the future of upper limb prostheses. We believe that surgical procedures for muscle reinnervation and osseointegration will become increasingly clinically relevant; muscle electrical signals will remain the main clinical means for prosthetic control; and chronic electrode implants, first in muscles (control), then in nerves (sensory feedback), will become viable clinical solutions. After decades of suspended clinically relevant progress, it is foreseeable that a new generation of upper limb prostheses will enter the market in the near future based on such advances, thereby offering substantial clinical benefit for patients.

  17. Temperature variations in sintering ovens for metal ceramic dental prostheses: non-destructive assessment using OCT

    NASA Astrophysics Data System (ADS)

    Sinescu, C.; Bradu, A.; Duma, V.-F.; Topala, F. I.; Negrutiu, M. L.; Podoleanu, A. G.

    2018-02-01

    We present a recent investigation regarding the use of optical coherence tomography (OCT) in the monitoring of the calibration loss of sintering ovens for the manufacturing of metal ceramic dental prostheses. Differences in the temperatures of such ovens with regard to their specifications lead to stress and even cracks in the prostheses material, therefore to the failure of the dental treatment. Evaluation methods of the ovens calibration consist nowadays of firing supplemental samples; this is subjective, expensive, and time consuming. Using an in-house developed swept source (SS) OCT system, we have demonstrated that a quantitative assessment of the internal structure of the prostheses, therefore of the temperature settings of the ovens can be made. Using en-face OCT images acquired at similar depths inside the samples, the differences in reflectivity allow for the evaluation of the differences in granulation (i.e., in number and size of ceramic grains) of the prostheses material. Fifty samples, divided in five groups, each sintered at different temperatures (lower, higher, or equal to the prescribed one) have been analyzed. The consequences of the temperature variations with regard to the one prescribed were determined. Rules-of-thumb were extracted to monitor objectively, using only OCT images of currently manufactured samples, the settings of the oven. The method proposed allows for avoiding producing prostheses with defects. While such rules-of-thumb achieve a qualitative assessment, an insight in our on-going work on the quantitative assessment of such losses of calibration on dental ovens using OCT is also made.

  18. Retention System and Splinting on Morse Taper Implants in the Posterior Maxilla by 3D Finite Element Analysis.

    PubMed

    Lemos, Cleidiel Aparecido Araujo; Verri, Fellippo Ramos; Santiago, Joel Ferreira; Almeida, Daniel Augusto de Faria; Batista, Victor Eduardo de Souza; Noritomi, Pedro Yoshito; Pellizzer, Duardo Piza

    2018-01-01

    The purpose of this study was to evaluate different retention systems (cement- or screw-retained) and crown designs (non-splinted or splinted) of fixed implant-supported restorations, in terms of stress distributions in implants/components and bone tissue, by 3-dimensional (3D) finite element analysis. Four 3D models were simulated with the InVesalius, Rhinoceros 3D, and SolidWorks programs. Models were made of type III bone from the posterior maxillary area. Models included three 4.0-mm-diameter Morse taper (MT) implants with different lengths, which supported metal-ceramic crowns. Models were processed by the Femap and NeiNastran programs, using an axial force of 400 N and oblique force of 200 N. Results were visualized as the von Mises stress and maximum principal stress (σmax). Under axial loading, there was no difference in the distribution of stress in implants/components between retention systems and splinted crowns; however, in oblique loading, cemented prostheses showed better stress distribution than screwed prostheses, whereas splinted crowns tended to reduce stress in the implant of the first molar. In the bone tissue cemented prostheses showed better stress distribution in bone tissue than screwed prostheses under axial and oblique loading. The splinted design only had an effect in the screwed prosthesis, with no influence in the cemented prosthesis. Cemented prostheses on MT implants showed more favorable stress distributions in implants/components and bone tissue. Splinting was favorable for stress distribution only for screwed prostheses under oblique loading.

  19. 3D printing and intraoperative neuronavigation tailoring for skull base reconstruction after extended endoscopic endonasal surgery: proof of concept.

    PubMed

    Essayed, Walid I; Unadkat, Prashin; Hosny, Ahmed; Frisken, Sarah; Rassi, Marcio S; Mukundan, Srinivasan; Weaver, James C; Al-Mefty, Ossama; Golby, Alexandra J; Dunn, Ian F

    2018-03-02

    OBJECTIVE Endoscopic endonasal approaches are increasingly performed for the surgical treatment of multiple skull base pathologies. Preventing postoperative CSF leaks remains a major challenge, particularly in extended approaches. In this study, the authors assessed the potential use of modern multimaterial 3D printing and neuronavigation to help model these extended defects and develop specifically tailored prostheses for reconstructive purposes. METHODS Extended endoscopic endonasal skull base approaches were performed on 3 human cadaveric heads. Preprocedure and intraprocedure CT scans were completed and were used to segment and design extended and tailored skull base models. Multimaterial models with different core/edge interfaces were 3D printed for implantation trials. A novel application of the intraoperative landmark acquisition method was used to transfer the navigation, helping to tailor the extended models. RESULTS Prostheses were created based on preoperative and intraoperative CT scans. The navigation transfer offered sufficiently accurate data to tailor the preprinted extended skull base defect prostheses. Successful implantation of the skull base prostheses was achieved in all specimens. The progressive flexibility gradient of the models' edges offered the best compromise for easy intranasal maneuverability, anchoring, and structural stability. Prostheses printed based on intraprocedure CT scans were accurate in shape but slightly undersized. CONCLUSIONS Preoperative 3D printing of patient-specific skull base models is achievable for extended endoscopic endonasal surgery. The careful spatial modeling and the use of a flexibility gradient in the design helped achieve the most stable reconstruction. Neuronavigation can help tailor preprinted prostheses.

  20. Paré and prosthetics: the early history of artificial limbs.

    PubMed

    Thurston, Alan J

    2007-12-01

    There is evidence for the use of prostheses from the times of the ancient Egyptians. Prostheses were developed for function, cosmetic appearance and a psycho-spiritual sense of wholeness. Amputation was often feared more than death in some cultures. It was believed that it not only affected the amputee on earth, but also in the afterlife. The ablated limbs were buried and then disinterred and reburied at the time of the amputee's death so the amputee could be whole for eternal life. One of the earliest examples comes from the 18th dynasty of ancient Egypt in the reign of Amenhotep II in the fifteenth century bc. A mummy in the Cairo Museum has clearly had the great toe of the right foot amputated and replaced with a prosthesis manufactured from leather and wood. The first true rehabilitation aids that could be recognized as prostheses were made during the civilizations of Greece and Rome. During the Dark Ages prostheses for battle and hiding deformity were heavy, crude devices made of available materials - wood, metal and leather. Such were the materials available to Ambroise Paré who invented both upper-limb and lower-limb prostheses. His 'Le Petit Lorrain', a mechanical hand operated by catches and springs, was worn by a French Army captain in battle. Subsequent refinements in medicine, surgery and prosthetic science greatly improved amputation surgery and the function of prostheses. What began as a modified crutch with a wooden or leather cup and progressed through many metamorphoses has now developed into a highly sophisticated prosthetic limb made of space-age materials.

  1. Pre-load on oral implants after screw tightening fixed full prostheses: an in vivo study.

    PubMed

    Duyck, J; Van Oosterwyck, H; Vander Sloten, J; De Cooman, M; Puers, R; Naert, I

    2001-03-01

    The fit of implant supported fixed prostheses is said to be of clinical concern because of the rigid fixation of an oral implant in its surrounding bone. The influence of the torque sequence of the set screws during fixation of implant supported fixed full prostheses on the final pre-load was investigated in vitro. No significant effect of the torque sequence of the set screws on the final pre-load was observed. The main objective of this study was to quantify and qualify the pre-load in vivo on implants supporting a fixed full prosthesis. This was performed when the prostheses were supported by all five or six implants and was repeated when the prostheses were supported by only four and three implants. A total of 13 patients with a fixed full implant supported prosthesis were selected. The existing abutments were changed for strain gauged abutments. After tightening the set screws with a torque of 10 N cm, the pre-load conditions were registered. The average (SEM) axial forces and bending moments in case of five or six, four and three supporting implants were 323 N (43 N), 346 N (59 N), 307 N (60 N) 21 N cm (3 N cm) and 21 N cm (2 N cm), 23 N cm (5 N cm), respectively. In addition, the pre-load was registered after fixation of a machined gold cylinder, as delivered by the manufacturer, on each of the supporting implants, representing the 'optimal fit' situation. The corresponding average (SEM) axial forces and bending moments in case of five or six, four and three supporting implants were 426 N (36 N), 405 N (40 N), 413 N (46 N) and 8 N cm (1 N cm), 8 N cm (1 N cm), 8 N cm (1 N cm), respectively. The induced axial forces after tightening the prostheses were significantly lower then after tightening the gold cylinder in case of five or six supporting implants (P < 0.02). The induced bending moments after tightening the prostheses were statistically significantly higher (P < 0.0001) then after tightening the gold cylinder in all test conditions (five or six, four or three supporting implants). This study underlines the static load present after screw tightening implant supported fixed full prostheses.

  2. Fatigue crack propagation behavior of ultrahigh molecular weight polyethylene.

    PubMed

    Connelly, G M; Rimnac, C M; Wright, T M; Hertzberg, R W; Manson, J A

    1984-01-01

    The relative fatigue crack propagation resistance of plain and carbon fiber-reinforced ultrahigh molecular weight polyethylene (UHMWPE) was determined from cyclic loading tests performed on compact tension specimens machined from the tibial components of total knee prostheses. Both materials were characterized by dynamic mechanical spectroscopy, X-ray diffraction, and differential scanning calorimetry. The cyclic tests used loading in laboratory air at 5 Hz using a sinusoidal wave form. Dynamic mechanical spectroscopy showed that the reinforced UHMWPE had a higher elastic storage modulus than the plain UHMWPE, whereas X-ray diffraction and differential scanning calorimetry showed that the percent crystallinity and degree of order in the crystalline regions were similar for the two materials. Fatigue crack propagation in both materials proved to be very sensitive to small changes in the applied cyclic stress intensity range. A 10% increase in stress intensity resulted in approximately an order of magnitude increase in fatigue crack growth rate. The fatigue crack propagation resistance of the reinforced UHMWPE was found to be significantly worse than that of the plain UHMWPE. This result was attributed to poor bonding between the carbon fibers and the UHMWPE matrix and the ductile nature of the matrix itself.

  3. Surface evaluation of orthopedic hip implants marketed in Brazil

    NASA Astrophysics Data System (ADS)

    Souza, M. M.; Trommer, R. M.; Maru, M. M.; Roesler, C. R. M.; Barros, W. S.; Dutra, M. S.

    2016-07-01

    One of the factors that contribute to the quality of total hip prostheses is the degree of accuracy in the manufacturing of the joint surfaces. The dimensional control of joint components is important because of its direct influence on the durability and, consequently, in the patients’ life quality. This work presents studies on the form and roughness of orthopedic hip prostheses marketed in Brazil. The results provide data for quality control of the surfaces of the femoral heads and acetabular components of hip prostheses and indicate the need of improvement in the procedures used to this control.

  4. Differential effects of speech prostheses in glossectomized patients.

    PubMed

    Leonard, R J; Gillis, R

    1990-12-01

    Five patients representing different categories of glossal resection were fitted with prostheses specifically designed to improve speech. Speech recordings made for subjects with and without their prostheses were subjected to a variety of analyses. Prosthetic influence on listeners' judgments of severity level/intelligibility, number of consonants in error, and on the acoustic measure F2 range of vowels was evaluated. Findings indicated that all subjects demonstrated improvement on the speech measures. However, the extent of improvement on each measure varied across speakers and resection categories. Implications of the findings for prosthetic speech rehabilitation in this population are discussed.

  5. Fabrication of a new silicone auricular prosthesis without removing the existing metallic framework.

    PubMed

    Goveas, Reiyal; Shrestha, Binit; Srithavaj, M L Theerathavaj; Thaworanunta, Sita

    2014-12-01

    Silicone prostheses require constant repair and refabrication. Auricular prostheses retained with implants have better retention than adhesive-retained prostheses. However, refabrication is complicated if the patient is unwilling to surrender the metallic framework attached to the implants and revert to the use of adhesives. This article describes a technique by which the metal framework of the existing prosthesis need not be removed, thereby improving the patient's quality of life until the new prosthesis is delivered. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  6. Re-operation for aortic and mitral prosthetic dysfunctions.

    PubMed

    Kaul, T K; Sastry, M R; Mercer, J L; Meade, J B

    1985-01-01

    The overall incidence of re-operation and prosthetic valve endocarditis was low in the present series as mechanical prostheses were used predominantly. The prosthetic dysfunctions were less frequent following the primary implantation with Bjork Shiley prostheses, but high operative risk was associated with the clotted Bjork Shiley prostheses. We also had unusual experience of strut fracture and sticking of Bjork Shiley discs in the closed position in both aortic and mitral positions. The early deaths were nil since the use of cardioplegic protection. Intra-operative bleeding due to adhesions can be minimised by using synthetic or heterologous pericardium during the primary operation.

  7. Design features of implants for direct skeletal attachment of limb prostheses

    PubMed Central

    Pitkin, M.

    2013-01-01

    In direct skeletal attachment (DSA) of limb prostheses, a construct is implanted into an amputee’s residuum bone and protrudes out of the residuum’s skin. This technology represents an alternative to traditional suspension of prostheses via various socket systems, with clear indications when the sockets cannot be properly fitted. Contemporary DSA was invented in the 1990s, and several implant systems have been introduced since then. The current review is intended to compare the design features of implants for DSA whose use in humans or in animal studies has been reported in the literature. PMID:23554122

  8. Complete denture analyzed by optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Negrutiu, Meda L.; Sinescu, Cosmin; Todea, Carmen; Podoleanu, Adrian G.

    2008-02-01

    The complete dentures are currently made using different technologies. In order to avoid deficiencies of the prostheses made using the classical technique, several alternative systems and procedures were imagined, directly related to the material used and also to the manufacturing technology. Thus, at the present time, there are several injecting systems and technologies on the market, that use chemoplastic materials, which are heat cured (90-100°C), in dry or wet environment, or cold cured (below 60°C). There are also technologies that plasticize a hard cured material by thermoplastic processing (without any chemical changes) and then inject it into a mold. The purpose of this study was to analyze the existence of possible defects in several dental prostheses using a non invasive method, before their insertion in the mouth. Different dental prostheses, fabricated from various materials were investigated using en-face optical coherence tomography. In order to discover the defects, the scanning was made in three planes, obtaining images at different depths, from 0,01 μm to 2 mm. In several of the investigated prostheses we found defects which may cause their fracture. These defects are totally included in the prostheses material and can not be vizualised with other imagistic methods. In conclusion, en-face OCT is an important investigative tool for the dental practice.

  9. Intensity-Modulated Radiation Therapy with Noncoplanar Beams for Treatment of Prostate Cancer in Patients with Bilateral Hip Prosthesis-A Case Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brooks, Chris; Cheung, Rex Min; Kudchadker, Rajat J.

    2010-07-01

    Megavoltage photon intensity-modulated radiation therapy (IMRT) is typically used in the treatment of prostate cancer at our institution. Approximately 1% to 2% of patients with prostate cancer have hip prostheses. The presence of the prosthesis usually complicates the planning process because of dose perturbation around the prosthesis, radiation attenuation through the prosthesis, and the introduction of computed tomography artifacts in the planning volume. In addition, hip prostheses are typically made of materials of high atomic number, which add uncertainty to the dosimetry of the prostate and critical organs in the planning volume. When the prosthesis is bilateral, treatment planning ismore » further complicated because only a limited number of beam angles can be used to avoid the prostheses. In this case study, we will report the observed advantages of using noncoplanar beams in the delivery of IMRT to a prostate cancer patient with bilateral hip prostheses. The treatment was planned for 75.6 Gy using a 7-field coplanar approach and a noncoplanar arrangement, with all fields avoiding entrance though the prostheses. Our results indicate that, compared with the coplanar plan, the noncoplanar plan delivers the prescribed dose to the target with a slightly better conformality and sparing of rectal tissue versus the coplanar plan.« less

  10. Movement quality of conventional prostheses and the DEKA Arm during everyday tasks

    PubMed Central

    Cowley, Jeffrey; Resnik, Linda; Wilken, Jason; Walters, Lisa Smurr; Gates, Deanna

    2017-01-01

    Background Conventional prosthetic devices fail to restore the function and characteristic movement quality of the upper limb. The DEKA Arm is a new, advanced prosthesis featuring a compound, powered wrist and multiple grip configurations. Objectives The purpose of this study was to determine if the DEKA Arm improved the movement quality of upper limb prosthesis users compared to conventional prostheses. Study design Case series. Methods Three people with transradial amputation completed tasks of daily life with their conventional prosthesis and with the DEKA Arm. A total of 10 healthy controls completed the same tasks. The trajectory of the wrist joint center was analyzed to determine how different prostheses affected movement duration, speed, smoothness, and curvature compared to patients’ own intact limbs and controls. Results Movement quality decreased with the DEKA Arm for two participants, and increased for the third. Prosthesis users made slower, less smooth, more curved movements with the prosthetic limb compared to the intact limb and controls, particularly when grasping and manipulating objects. Conclusion The effects of one month of training with the DEKA Arm on movement quality varied with participants’ skill and experience with conventional prostheses. Future studies should examine changes in movement quality after long-term use of advanced prostheses. PMID:26932980

  11. Soldering in prosthodontics--an overview, part I.

    PubMed

    Byrne, Gerard

    2011-04-01

    The fit of fixed multiunit dental prostheses (FDP), traditionally termed fixed partial dentures (FPDs), is an ongoing problem. Poorly fitting restorations may hasten mechanical failure, due to abutment caries or screw failure. Soldering and welding play an important role in trying to overcome misfit of fixed multiunit prostheses. The term FPD will be used to denote multiunit fixed dental prostheses in this review. This is the first of a series of articles that review the state of the art and science of soldering and welding in relation to the fit of cemented or screw-retained multiunit prostheses. A comprehensive archive of background information and scientific findings is presented. Texts in dental materials and prosthodontics were reviewed. Scientific data were drawn from the numerous laboratory studies up to and including 2009. The background, theory, terminology, and working principles, along with the applied research, are presented. This first article focuses on soldering principles and dimensional accuracy in soldering. There is some discussion and suggestions for future research and development. Soldering may improve dimensional accuracy or reduce the distortion of multiunit fixed prostheses. Many variables can affect the outcome in soldering technique. Research science has developed some helpful guidelines. Research projects are disconnected and limited in scope. © 2011 by The American College of Prosthodontists.

  12. Fracture resistance and failure mode of posterior fixed dental prostheses fabricated with two zirconia CAD/CAM systems

    PubMed Central

    López-Suárez, Carlos; Gonzalo, Esther; Peláez, Jesús; Rodríguez, Verónica

    2015-01-01

    Background In recent years there has been an improvement of zirconia ceramic materials to replace posterior missing teeth. To date little in vitro studies has been carried out on the fracture resistance of zirconia veneered posterior fixed dental prostheses. This study investigated the fracture resistance and the failure mode of 3-unit zirconia-based posterior fixed dental prostheses fabricated with two CAD/CAM systems. Material and Methods Twenty posterior fixed dental prostheses were studied. Samples were randomly divided into two groups (n=10 each) according to the zirconia ceramic analyzed: Lava and Procera. Specimens were loaded until fracture under static load. Data were analyzed using Wilcoxon´s rank sum test and Wilcoxon´s signed-rank test (P<0.05). Results Partial fracture of the veneering porcelain occurred in 100% of the samples. Within each group, significant differences were shown between the veneering and the framework fracture resistance (P=0.002). The failure occurred in the connector cervical area in 80% of the cases. Conclusions All fracture load values of the zirconia frameworks could be considered clinically acceptable. The connector area is the weak point of the restorations. Key words:Fixed dental prostheses, zirconium-dioxide, zirconia, fracture resistance, failure mode. PMID:26155341

  13. Evaluation of Osseous Integration of PVD-Silver-Coated Hip Prostheses in a Canine Model

    PubMed Central

    Hauschild, Gregor; Hardes, Jendrik; Gosheger, Georg; Blaske, Franziska; Wehe, Christoph; Karst, Uwe; Höll, Steffen

    2015-01-01

    Infection associated with biomaterials used for orthopedic prostheses remains a serious complication in orthopedics, especially tumor surgery. Silver-coating of orthopedic (mega)prostheses proved its efficiency in reducing infections but has been limited to surface areas exposed to soft tissues due to concerns of silver inhibiting osseous integration of cementless stems. To close this gap in the bactericidal capacity of silver-coated orthopedic prostheses extension of the silver-coating on surface areas intended for osseous integration seems to be inevitable. Our study reports about a PVD- (physical-vapor-deposition-) silver-coated cementless stem in a canine model for the first time and showed osseous integration of a silver-coated titanium surface in vivo. Radiological, histological, and biomechanical analysis revealed a stable osseous integration of four of nine stems implanted. Silver trace elemental concentrations in serum did not exceed 1.82 parts per billion (ppb) and can be considered as nontoxic. Changes in liver and kidney functions associated with the silver-coating could be excluded by blood chemistry analysis. This was in accordance with very limited metal displacement from coated surfaces observed by laser ablation inductively coupled plasma-mass spectrometry (LA-ICP-MS) 12 months after implantation. In conclusion our results represent a step towards complete bactericidal silver-coating of orthopedic prostheses. PMID:25695057

  14. [A scanning electron microscopy study of the surface of porous-textured breast implants and their capsules. Description of the "velcro" effect of porous-textured breast prostheses].

    PubMed

    Danino, A; Rocher, F; Blanchet-Bardon, C; Revol, M; Servant, J M

    2001-02-01

    The efficacy of breast prosthesis texturing in the prevention of capsular contracture has been established for about 20 years. This successful procedure has led to the development and marketing of a number of different models. In the present study, four porous-textured breast prostheses have been examined: the Arion monoblock implant, the CUI (McGahn), the Biocell (Mcgahn), and the Sebbin LS21. Scanning electron microscopic (SEM) investigation of the implant surfaces of the different prostheses was carried out on new samples received from the manufacturers. During a prospective study on eight patients, capsule samples corresponding to the four above-mentioned prostheses were taken to determine whether a secondary intervention was necessary for correction of asymmetry or malpositioning. These samples were analyzed by SEM to investigate whether there could be a correlation between prosthesis texturing and the aspect of the corresponding capsules. Significant ultrastructural differences were found between the various prostheses examined: the results showed that only the CUI and Biocell prostheses presented a mirror image of the capsule texturing, with a correspondence between the depressions on the prosthesis and the contacts on the capsule. This finding seems to be linked to the existence of a critical size for the pores that constitute the implant surface. This observation led to the hypothesis of an adhesive "velcro" effect between the prosthesis and its capsule. Although the latter may not be directly linked to the prevention of capsular contracture it can, however, have a major effect on implant stabilization in cases of primary breast reconstruction and in possible secondary adjustments of asymmetry and malpositioning.

  15. Mastication and oral health-related quality of life in removable denture wearers with Alzheimer disease.

    PubMed

    Campos, Camila H; Ribeiro, Giselle R; Rodrigues Garcia, Renata C M

    2018-05-01

    Alzheimer disease (AD) can affect masticatory function, affecting oral health-related quality of life (OHRQoL). Whether oral rehabilitation with conventional removable prostheses can restore masticatory function and improve OHRQoL in these individuals is unknown. The purpose of this clinical study was to evaluate the influence of oral rehabilitation with removable prostheses on masticatory efficiency and OHRQoL in elders with and without AD. Thirty-two elders with mild AD (n=16, mean age=76.7 ±6.3 years) or without AD (n=16, mean age=75.2 ±4.4 years) were recruited. All participants first underwent masticatory efficiency and OHRQoL evaluations, and 2 months after insertion of new removable prostheses, the variables were reassessed. Masticatory efficiency was determined using the sieving method, and OHRQoL was measured by applying the Geriatric Oral Health Assessment Index (GOHAI). The data from the baseline and after insertion of the new removable prostheses were compared by paired t test. Group differences at each time point were assessed by t test (α=.05). After insertion of the new removable prostheses, masticatory efficiency and OHRQoL improved in both the elders with AD and the control. At baseline, elders with AD had lower masticatory efficiency and higher OHRQoL than controls (P<.05). After removable prosthesis insertion, elders with AD continued to show lower masticatory efficiency values than controls, but their OHRQoL was similar. Oral rehabilitation with new removable prostheses improved the masticatory efficiency and OHRQoL of elders with and without AD, although masticatory efficiency did not reach control levels in elders with AD. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  16. Evaluation of the Alteration of Occlusal Distribution in Unilateral Free-End and Intermediate Missing Cases.

    PubMed

    Kon, Kazuhiro; Shiota, Makoto; Sakuyama, Aoi; Ozeki, Maho; Kozuma, Wataru; Kawakami, Sawako; Kasugai, Shohei

    2017-02-01

    The present study aimed to evaluate the effect of implant prostheses on the occlusal force and area as well as the distribution of occlusal loading in unilateral free-end and intermediate missing cases. Fourteen healthy subjects (7 free-end missing cases in the first and second molars and 7 intermediate missing cases in the first molar region) were included. Six months after the implant prosthesis was placed, an occlusal evaluation was performed with or without the implant superstructure by using Dental Prescale film and an occluder device. In free-end missing cases, the total occlusal force and area, implant-side occlusal force and area, and implant-side occlusal force and area of the residual natural teeth were significantly affected by the implant prostheses. In intermediate missing cases, the implant-side occlusal force of the residual natural teeth was significantly affected by the implant prostheses. In free-end missing cases, the proportions of implant-side occlusal force, non-implant-side occlusal force, and implant-side occlusal force of the residual natural teeth relative to the total occlusal force were significantly affected by the implant prostheses. In the intermediate missing cases, the proportion of the implant-side occlusal force of the residual natural teeth relative to the total occlusal force was significantly affected by the implant prostheses. The proportion of the occlusal area was also significantly affected. In free-end missing cases, implant prostheses significantly increased the occlusal force and area, which resulted in the proper occlusal distribution. In intermediate missing cases, an implant prosthesis may only improve the same-side occlusal loading of the natural teeth.

  17. Characterisation of the responsive properties of two running-specific prosthetic models.

    PubMed

    Grobler, Lara; Ferreira, Suzanne; Vanwanseele, Benedicte; Terblanche, Elmarie E

    2017-04-01

    The need for information regarding running-specific prosthetic properties has previously been voiced. Such information is necessary to assist in athletes' prostheses selection. This study aimed to describe the characteristics of two commercially available running-specific prostheses. The running-specific prostheses were tested (in an experimental setup) without the external interference of athlete performance variations. Four stiffness categories of each running-specific prosthetic model (Xtend ™ and Xtreme ™ ) were tested at seven alignment setups and three drop masses (28, 38 and 48 kg). Results for peak ground reaction force (GRF peak ), contact time ( t c ), flight time ( t f ), reactive strength index (RSI) and maximal compression (Δ L) were determined during controlled dropping of running-specific prostheses onto a force platform with different masses attached to the experimental setup. No statistically significant differences were found between the different setups of the running-specific prostheses. Statistically significant differences were found between the two models for all outcome variables (GRF peak , Xtend > Xtreme; t c , Xtreme > Xtend; t f , Xtreme > Xtend; RSI, Xtend > Xtreme; Δ L, Xtreme > Xtend; p < 0.05). These findings suggest that the Xtreme stores more elastic energy than the Xtend, leading to a greater performance response. The specific responsive features of blades could guide sprint athletes in their choice of running-specific prostheses. Clinical relevance Insights into the running-specific prosthesis (RSP) properties and an understanding of its responsive characteristics have implications for athletes' prosthetic choice. Physiologically and metabolically, a short sprint event (i.e. 100 m) places different demands on the athlete than a long sprint event (i.e. 400 m), and the RSP should match these performance demands.

  18. Usefulness of Mitral Valve Prosthetic or Bioprosthetic Time Velocity Index Ratio to Detect Prosthetic or Bioprosthetic Mitral Valve Dysfunction.

    PubMed

    Luis, Sushil Allen; Blauwet, Lori A; Samardhi, Himabindu; West, Cathy; Mehta, Ramila A; Luis, Chris R; Scalia, Gregory M; Miller, Fletcher A; Burstow, Darryl J

    2017-10-15

    This study aimed to investigate the utility of transthoracic echocardiographic (TTE) Doppler-derived parameters in detection of mitral prosthetic dysfunction and to define optimal cut-off values for identification of such dysfunction by valve type. In total, 971 TTE studies (647 mechanical prostheses; 324 bioprostheses) were compared with transesophageal echocardiography for evaluation of mitral prosthesis function. Among all prostheses, mitral valve prosthesis (MVP) ratio (ratio of time velocity integral of MVP to that of left ventricular outflow tract; odds ratio [OR] 10.34, 95% confidence interval [95% CI] 6.43 to 16.61, p<0.001), E velocity (OR 3.23, 95% CI 1.61 to 6.47, p<0.001), and mean gradient (OR 1.13, 95% CI 1.02 to 1.25, p=0.02) provided good discrimination of clinically normal and clinically abnormal prostheses. Optimal cut-off values by receiver operating characteristic analysis for differentiating clinically normal and abnormal prostheses varied by prosthesis type. Combining MVP ratio and E velocity improved specificity (92%) and positive predictive value (65%) compared with either parameter alone, with minimal decline in negative predictive value (92%). Pressure halftime (OR 0.99, 95% CI 0.98 to 1.00, p=0.04) did not differentiate between clinically normal and clinically abnormal prostheses but was useful in discriminating obstructed from normal and regurgitant prostheses. In conclusion, cut-off values for TTE-derived Doppler parameters of MVP function were specific to prosthesis type and carried high sensitivity and specificity for identifying prosthetic valve dysfunction. MVP ratio was the best predictor of prosthetic dysfunction and, combined with E velocity, provided a useful parameter for determining likelihood of dysfunction and need for further assessment. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  19. Occlusal contact of fixed implant prostheses using functional bite impression technique.

    PubMed

    Suzuki, Yasunori; Shimpo, Hidemasa; Ohkubo, Chikahiro

    2015-02-01

    Functional bite impression (FBI) has been described as a definitive impression made under occlusal force after functional generated path (FGP) recording. This study compared the accuracy of occlusal contact of implant-fixed prostheses using the FBI technique and the conventional impression technique. Twelve subjects, each missing a single premolar or molar, were selected for this study. The conditions of the occlusal contacts were identified by the modified transillumination method. The occlusal contact condition was determined by comparing the rate of change in the occlusal contact area of the implant-fixed prostheses and both adjacent teeth before and after occlusal adjustment. The rate of change in the occlusal contact area using the FBI technique was 96%, and the rate using the conventional technique was 54%. The occlusal contact of implant prostheses using the FBI technique revealed better accuracy than that of the conventional technique. Regarding the FBI technique, a precise and functional prosthesis could be produced by completing the maxillomandibular registration, impression, and FGP at the same time.

  20. Impact of implant-supported prostheses on nutritional status and oral health perception in edentulous patients.

    PubMed

    El Osta, Nada; El Osta, Lana; Moukaddem, Farah; Papazian, Tatiana; Saad, Robert; Hennequin, Martine; Rabbaa Khabbaz, Lydia

    2017-04-01

    Improvement of nutritional status and perception of oral health are supposed to be different with complete conventional denture or implant-supported fixed or removable prostheses. Since no study has been conducted in Lebanon, the aim of our study was to assess the nutritional status and oral heath related quality of life (OHRQoL) in totally edentulous patients after treatment with complete denture or implant supported-prostheses. This was an observational clinical prospective study. A convenient sample of Lebanese people aged 60 years or more was selected between September 2013 and July 2015 from the Departments of removable and fixed prosthesis at Saint-Joseph University of Beirut. The treatment options included complete denture, implant-supported complete denture and implant-supported fixed prostheses. Nutritional status and OHRQoL were assessed with the Mini-Nutritional Assessment Index (MNA) and the Geriatric Oral Health Assessment Index (GOHAI) respectively at Baseline (first visit before treatment), 2-3 weeks after treatment (t1), 3 months (t2) and 6 months (t3) after treatment. Fifty-one participants (mean age: 69.39 ± 7.164 years) were included. The results have shown an improvement over time in nutritional status and OHRQoL for all treatment groups. However, 2-3 weeks after treatment the number of participants at risk of malnutrition was higher with complete removable denture, intermediate with implant-supported complete denture and lower with implant-supported fixed prostheses (p-value = 0.049). Moreover, the mean GOHAI score was significantly lower over time with complete removable denture compared to implant-supported prostheses (p-value <0.05). Our study has shown an enhancement in the quality of life and the nutritional status for implant supported-prostheses compared to conventional removable dentures. Therefore, it is fundamental that dentists communicate with their patients about implant treatment to understand their expectations, to explain the outcomes and achieve the desired clinical result. Copyright © 2017 European Society for Clinical Nutrition and Metabolism. Published by Elsevier Ltd. All rights reserved.

  1. Clinical performance of removable dental prostheses in the moderately reduced dentition: a systematic literature review.

    PubMed

    Moldovan, Ovidiu; Rudolph, Heike; Luthardt, Ralph G

    2016-09-01

    Evidence-based therapeutic recommendations for removable dental prostheses are still lacking. The aim of the present study was a systematic review and meta-analysis of the survival rates of removable dentures in the moderately reduced dentition. In 2014, a systematic literature search in established medical databases (MEDLINE, EMBASE, BIOSIS, SciSearch, Cochrane, FIZ Technik Web) and a hand search of relevant dental journals were conducted. The search terms were relevant MeSH terms, free search terms, and combinations of the two. The search included RCTs, prospective and retrospective studies on survival rates of removable dental prostheses in the moderately reduced dentition with at least 15 participants, an observation period of at least 2 years, and a dropout rate of less than 25 %. The selection of relevant publications was carried out at the title, abstract, and full-text level by at least two of the authors involved. The publications included were tabulated and analyzed. Of the original 12,994 matches, 1923 were analyzed by title, 650 by abstract, and 111 according to the full text. The final review included 19 publications, of which 6 were multiple publications. Cast-metal framework dentures exhibited failure rates of between 33 and 50 % after 5 years. One study with a 25-year observation period reported failure rates of 50 %. Better results were obtained with proper pretreatment and a good recall scheme. Bilateral attachment prostheses showed failure rates of between 11 and 30 % after 5 years. Unilateral attachment prostheses showed failure rates of 75 % after 5 years. Double-crown prostheses dentures show failure rates of 0 to 21.7 % after 3 to 6 years. Heterogeneous study designs and data analyses rendered a meta-analysis impossible, so that an evaluation at the highest level of evidence could not be performed. Within the limitations of this study, it would be correct to state that removable dental prostheses, given suitable pretreatment and follow-up regimes, can provide satisfactory solutions. Based on only one paper, they revealed acceptable results even over a very long observation period (25 years).

  2. In vitro comparative analysis of the fit of gold alloy or commercially pure titanium implant-supported prostheses before and after electroerosion.

    PubMed

    Sartori, Ivete Aparecida de Mattias; Ribeiro, Ricardo Faria; Francischone, Carlos Eduardo; de Mattos, Maria da Gloria Chiarello

    2004-08-01

    For implant-supported prostheses, passive fit is critical for the success of rehabilitation, especially when alternative materials are used. The purpose of this study was to compare interfacial fit of implant-supported prostheses cast in titanium to those cast in gold alloy. Five 3-unit fixed partial dentures were fabricated in gold alloy (Degudent U) as 1-piece castings, and 5 others were similarly cast in commercially pure titanium (Grade 1). The interfacial gaps between the prostheses and the abutments were evaluated with an optical microscope, before and after electroerosion. Readings were made with both screws tightened (10 N.cm torque), and with only 1 side tightened, so as to also evaluate the passive fit of the prostheses. Data were compared statistically by 2-way analysis of variance and the post hoc Tukey multiple range test (alpha=.05). Before electroerosion, the interfacial gaps for the 1-piece prostheses were significantly smaller (P<.001) in the gold alloy group when the screws were tightened (Au=12.6 +/- 3.0 microm, compared to Ti=30.1 +/- 6.4 microm). When the side opposite the tightened side was analyzed, there was no significant difference between the gold alloy and titanium groups (Au=69.2 +/- 24.9 microm and Ti=94.2 +/- 39.6 microm). The electroerosion procedure significantly (P<.001) reduced the gaps at the interfaces for both groups under all conditions. Comparison between groups after electroerosion did not present significant differences when the side opposite the tightened side was analyzed, but the gold alloy group showed better fit when the tightened side was analyzed (12.8 +/- 1.4 microm for gold alloy; 29.6 +/- 4.4 microm for titanium) and when both screws were tightened (5.4 +/- 2.3 microm for gold alloy; 16.1 +/- 5.5 microm for titanium). Cast titanium prostheses, despite showing larger interfacial gaps between the prosthesis and abutment than those obtained with gold alloy, had improved fit after being subjected to electroerosion.

  3. Recent advances in bioelectric prostheses

    PubMed Central

    Pasquina, Paul F.; Perry, Briana N.; Miller, Matthew E.; Ling, Geoffrey S.F.; Tsao, Jack W.

    2015-01-01

    Summary Worldwide prevalence of amputation has created an increasing demand for improved upper and lower extremity prostheses. Current prosthetics are often uncomfortable and difficult to control and provide limited functional restoration. Moreover, the inability to normalize anthropomorphic biomechanics with a prosthesis increases one's risk of developing long-term health risks such as arthritis, skin breakdown, and pain. Recent advances in bionic prosthetic development hold great promise for rehabilitation and improving quality of life with limb loss. This brief review discusses the current state of advanced prostheses, the integration of robotics in the care of individuals with major limb amputation, and some innovative surgical techniques that are being explored for clinical feasibility. PMID:29443190

  4. Processing of hydroxylapatite coatings on titanium alloy bone prostheses

    DOEpatents

    Nastasi, M.A.; Levine, T.E.; Mayer, J.W.; Pizziconi, V.B.

    1998-10-06

    Processing of hydroxylapatite sol-gel films on titanium alloy bone prostheses. A method utilizing non-line-of-sight ion beam implantation and/or rapid thermal processing to provide improved bonding of layers of hydroxylapatite to titanium alloy substrates while encouraging bone ingrowth into the hydroxylapatite layers located away from the substrate, is described for the fabrication of prostheses. The first layer of hydroxylapatite is mixed into the substrate by the ions or rapidly thermally annealed, while subsequent layers are heat treated or densified using ion implantation to form layers of decreasing density and larger crystallization, with the outermost layers being suitable for bone ingrowth.

  5. Processing of hydroxylapatite coatings on titanium alloy bone prostheses

    DOEpatents

    Nastasi, Michael A.; Levine, Timothy E.; Mayer, James W.; Pizziconi, Vincent B.

    1998-01-01

    Processing of hydroxylapatite sol-gel films on titanium alloy bone prostheses. A method utilizing non-line-of-sight ion beam implantation and/or rapid thermal processing to provide improved bonding of layers of hydroxylapatite to titanium alloy substrates while encouraging bone ingrowth into the hydroxylapatite layers located away from the substrate, is described for the fabrication of prostheses. The first layer of hydroxylapatite is mixed into the substrate by the ions or rapidly thermally annealed, while subsequent layers are heat treated or densified using ion implantation to form layers of decreasing density and larger crystallization, with the outermost layers being suitable for bone ingrowth.

  6. 28 CFR 43.1 - Administrative determination and assertion of claims.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... for the furnishing of hospital, medical, surgical or dental care and treatment (including prostheses... dental care and treatment was or will be furnished for an injury or disease caused under circumstances..., medical, surgical, or dental care and treatment (including prostheses and medical appliances) furnished by...

  7. Thermoelastic stress analysis to validate tibial fixation technique in total ankle prostheses - a pilot study.

    PubMed

    Ficklscherer, Andreas; Wegener, Bernd; Niethammer, Thomas; Pietschmann, Matthias F; Müller, Peter E; Jansson, Volkmar; Trouillier, Hans-Heinrich

    2013-03-01

    Recent literature has shown a persistently high rate of aseptic loosening of the tibial component in total ankle prostheses. We analyzed the interface between the tibial bone and tibial component with a thermoelastic stress analysis to demonstrate load transmission onto the distal tibia. In this regard, we used two established ankle prostheses, which were implanted in two human cadaveric and in two third-generation composite tibia bones (Sawbones®, Sweden). Subsequently, the bones were attached to a hydropulser and a sinusoidal load of 700 N was applied. Both prostheses had an inhomogeneous load transmission onto the distal tibia. Instead of distributing load equally to the subarticular bone, forces were focused around the bolting stem, accumulating as stress maxima with forces up to 90 MPa. Furthermore, we were able to demonstrate load transmission into the metaphysis of the bone. As demonstrated in this study, anchoring systems with stems used in all established total ankle prostheses lead to an inhomogeneous load transmission onto the distal tibia, and furthermore, to a distribution of load into the weaker metaphyseal bone. For these reasons, we favor a prosthetic design with minimal bone resection and without any stem or stem-like anchoring system, which facilitates a homogeneous load transmission onto the distal tibia. Thermoelastic stress analysis proved to be a fast and easy-to-perform method to visualize load transmission.

  8. Framework design and pontics of fiber-reinforced composite fixed dental prostheses - An overview.

    PubMed

    Perea-Lowery, Leila; Vallittu, Pekka K

    2018-05-11

    Fiber-reinforced composite (FRC) fixed dental prostheses (FDPs) have shown good performance in clinical applications due to their good mechanical properties and minimally invasive approach. However, typical failure patterns of FRC FDPs are often localized at the pontic site. That reflects the structural considerations at the framework and pontic location that need to be examined when creating these kinds of prostheses. Peer-reviewed articles and other scientific literature were reviewed for providing up-to-date information on how pontics of FRC FDPs can be made. A thorough literature search was done using PubMed and Google Scholar. Two individuals did an assessment of the articles in order to include those related to pontics and framework design of FRC FDPs. The search terms used were "fiber-reinforced dental prosthesis" and "Pontics of fiber-reinforced dental prosthesis". These findings indicate that a cross-sectional fiber design, substructure and thicker pontics made of a variety of materials might reduce failures at the pontic site. The thickness of pontics of FRC FDPs interrelated with the vertical positioning of the FRC framework influences the load-bearing capacities of prostheses of these kinds. The understanding of the factors involved in the fabrication of pontics of FRC FDPs may overcome the drawbacks identified in these prostheses, thus extending their longevity. Copyright © 2018 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  9. Three-phase bone scan and indium white blood cell scintigraphy following porous coated hip arthroplasty: A prospective study of the prosthetic tip

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oswald, S.G.; Van Nostrand, D.; Savory, C.G.

    1989-08-01

    Although few reports address the use of three-phase bone scanning (TPBS) and {sup 111}In-labeled white blood cell (In-WBC) scintigraphy in hip arthroplasty utilizing a porous coated prosthesis, the literature suggests that scintigraphic patterns in the uncomplicated patient may differ from that seen in the cemented prosthesis. In an attempt to determine the scintigraphic natural history, 25 uncomplicated porous coated hip arthroplasties in 21 patients were prospectively studied with serial TPBS and In-WBC at approximately 7 days, and at 3, 6, 12, 18, and 24 mo postoperatively. This report deals with findings related to the prosthetic tip. Only one of 136more » flow studies were abnormal and only two of 136 blood-pool images demonstrated focally increased activity. All 25 prostheses (120 of 143 scans) demonstrated increased uptake on the bone phase images. The area about the tip was divided into three segments; increased uptake at 24 mo was noted in the medial, distal, and lateral segments in 16%, 72%, and 56% of prostheses, respectively. Twenty of 25 prostheses (82 of 142 scans) showed uptake on In-WBC scintigraphy, being noted in 48% of prostheses at 24 mo. We conclude that scintigraphic patterns in the uncomplicated patient with a porous coated prosthesis appear to differ from patterns described in cemented prostheses.« less

  10. Experimental and computational investigation of Morse taper conometric system reliability for the definition of fixed connections between dental implants and prostheses.

    PubMed

    Bressan, Eriberto; Lops, Diego; Tomasi, Cristiano; Ricci, Sara; Stocchero, Michele; Carniel, Emanuele Luigi

    2014-07-01

    Nowadays, dental implantology is a reliable technique for treatment of partially and completely edentulous patients. The achievement of stable dentition is ensured by implant-supported fixed dental prostheses. Morse taper conometric system may provide fixed retention between implants and dental prostheses. The aim of this study was to investigate retentive performance and mechanical strength of a Morse taper conometric system used as implant-supported fixed dental prostheses retention. Experimental and finite element investigations were performed. Experimental tests were achieved on a specific abutment-coping system, accounting for both cemented and non-cemented situations. The results from the experimental activities were processed to identify the mechanical behavior of the coping-abutment interface. Finally, the achieved information was applied to develop reliable finite element models of different abutment-coping systems. The analyses were developed accounting for different geometrical conformations of the abutment-coping system, such as different taper angle. The results showed that activation process, occurred through a suitable insertion force, could provide retentive performances equal to a cemented system without compromising the mechanical functionality of the system. These findings suggest that Morse taper conometrical system can provide a fixed connection between implants and dental prostheses if proper insertion force is applied. Activation process does not compromise the mechanical functionality of the system. © IMechE 2014.

  11. The Ball Welding Bar: A New Solution for the Immediate Loading of Screw-Retained, Mandibular Fixed Full Arch Prostheses

    PubMed Central

    Bacchiocchi, Danilo

    2017-01-01

    Purpose To present a new intraoral welding technique, which can be used to manufacture screw-retained, mandibular fixed full-arch prostheses. Methods Over a 4-year period, all patients with complete mandibular edentulism or irreparably compromised mandibular dentition, who will restore the masticatory function with a fixed mandibular prosthesis, were considered for inclusion in this study. The “Ball Welding Bar” (BWB) technique is characterised by smooth prosthetic cylinders, interconnected by means of titanium bars which are adjustable in terms of distance from ball terminals and are inserted in the rotating rings of the cylinders. All the components are welded and self-posing. Results Forty-two patients (18 males; 24 females; mean age 64.2 ± 6.7 years) were enrolled and 210 fixtures were inserted to support 42 mandibular screw-retained, fixed full-arch prostheses. After two years of loading, 2 fixtures were lost, for an implant survival rate of 97.7%. Five implants suffered from peri-implant mucositis and 3 implants for peri-implantitis. Three of the prostheses (3/42) required repair for fracture (7.1%): the prosthetic success was 92.9%. Conclusions The BWB technique seems to represent a reliable technique for the fabrication of screw-retained mandibular fixed full-arch prostheses. This study was registered in the ISRCTN register with number ISRCTN71229338. PMID:28835752

  12. Clinical experiences of implant-supported prostheses with laser-welded titanium frameworks in the partially edentulous jaw: a 5-year follow-up study.

    PubMed

    Ortorp, A; Jemt, T

    1999-01-01

    Titanium frameworks have been used in the endentulous implant patient for the last 10 years. However, knowledge of titanium frameworks for the partially dentate patient is limited. To report the 5-year clinical performance of implant-supported prostheses with laser-welded titanium frameworks in the partially edentulous jaw. A consecutive group of 383 partially edentulous patients were, on a routine basis, provided with fixed partial prostheses supported by Brånemark implants in the mandible or maxilla. Besides conventional frameworks in cast gold alloy, 58 patients were provided with titanium frameworks with three different veneering techniques, and clinical and radiographic 5-year data were collected for this group. The overall cumulative survival rate was 95.6% for titanium-framework prostheses and 93.6% for implants. Average bone loss during the follow-up period was 0.4 mm. The most common complications were minor veneering fractures. Loose and fractured implant screw components were fewer than 2%. An observation was that patients on medications for cardiovascular problems may lose more implants than others (p < .05). The clinical performance of prostheses with implant-supported laser-welded titanium frameworks was similar to that reported for conventional cast frames in partially edentulous jaws. Low-fusing porcelain veneers also showed clinical performance comparable to that reported for conventional porcelain-fused-to-metal techniques.

  13. A first experience with digital complete overdentures.

    PubMed

    Bajunaid, Salwa Omar

    2016-07-01

    The development of computer-aided design/computer-aided manufacturing systems for dentistry in the 1980s resulted in the successful fabrication of crowns, fixed dental prostheses, and superstructures for both natural teeth and dental implants. Today, this technology is available for constructing digitally designed and milled, completely removable dental prostheses. The procedure uses clinical and laboratory protocols that allow fabrication of completely removable prostheses within two clinical appointments. The aim of this clinical report is to present the author's first experience with digital complete overdentures, the practicality of this technology, and patient feedback. Compared with conventional overdentures, the fit of the digital prostheses was improved because the cameo and flanges of the prostheses were nicely shaped and rolled, and this enhanced their stability and retention. Occlusion was also excellent. However, aesthetics in terms of the alignment, shape, and size of the maxillary overdenture teeth were inacceptable. Despite some of the drawbacks identified in our study, the use of removable digital dentures does provide excellent adaptation of the denture base and requires fewer clinic visits. We anticipate that the unsatisfactory aesthetic outcomes presented in this report can be corrected with more experience. We also believe that acquiring an in-house scanning machine would be beneficial. We highly recommend including this technique in dental school curriculums at both the undergraduate and graduate levels in order to keep students and residents up to date on the latest technology available.

  14. Use and Usefulness of Lower Limb Prostheses.

    ERIC Educational Resources Information Center

    Buijk, Catharina A.

    1988-01-01

    Adults (n=181) in the Netherlands were surveyed concerning their use of lower limb prostheses. Results are analyzed in terms of age and sex of users, reason for amputation, level of amputation, description of prosthesis, amount of time able to walk or stand, satisfaction with the prosthesis, and user recommendations. (JDD)

  15. Agile Development of Advanced Prototypes

    DTIC Science & Technology

    2014-11-01

    prostheses: retinal implants, cochlear implants, and neuroprosthetics (EEG controlled artificial limbs); an interactive, virtual experience...demonstrations allowing users to experience, from a patient’s perspective life with three different prostheses: retinal implants, cochlear implants...three experiences were researched and developed. The applications are interactive demonstrations of retinal implants, cochlear implants, and

  16. Updates in inflatable penile prostheses.

    PubMed

    Henry, Gerard D; Wilson, Steven K

    2007-11-01

    Throughout history, many attempts to correct erectile dysfunction (ED) have been recorded. For the last 35 years, intracavernosal inflatable prostheses have been used, and these devices have undergone almost constant enhancement. The three-piece inflatable penile prosthesis has the highest patient satisfaction rates and lowest mechanical revision rates of almost any medically implanted device.

  17. Peak-picking fundamental period estimation for hearing prostheses.

    PubMed

    Howard, D M

    1989-09-01

    A real-time peak-picking fundamental period estimation device is described which is used in advanced hearing prostheses for the totally and profoundly deafened. The operation of the peak picker is compared with three well-established fundamental frequency estimation techniques: the electrolaryngograph, which is used as a "standard" hardware implementations of the cepstral technique, and the Gold/Rabiner parallel processing algorithm. These comparisons illustrate and highlight some of the important advantages and disadvantages that characterize the operation of these techniques. The special requirements of the hearing prostheses are discussed with respect to the operation of each device, and the choice of the peak picker is found to be felicitous in this application.

  18. Manufacturing implant supported auricular prostheses by rapid prototyping techniques.

    PubMed

    Karatas, Meltem Ozdemir; Cifter, Ebru Demet; Ozenen, Didem Ozdemir; Balik, Ali; Tuncer, Erman Bulent

    2011-08-01

    Maxillofacial prostheses are usually fabricated on the models obtained following the impression procedures. Disadvantages of conventional impression techniques used in production of facial prosthesis are deformation of soft tissues caused by impression material and disturbance of the patient due to. Additionally production of prosthesis by conventional methods takes longer time. Recently, rapid prototyping techniques have been developed for extraoral prosthesis in order to reduce these disadvantages of conventional methods. Rapid prototyping technique has the potential to simplify the procedure and decrease the laboratory work required. It eliminates the need for measurement impression procedures and preparation of wax model to be performed by prosthodontists themselves In the near future this technology will become a standard for fabricating maxillofacial prostheses.

  19. External breast prostheses. A survey of their use by women after mastectomy.

    PubMed

    Tanner, R; Abraham, S F; Llewellyn-Jones, D

    1983-03-19

    Women who have had a mastectomy for breast cancer have to cope with two major problems: first, that they have cancer, and second, that they have lost their physical appearance. The provision of an appropriate prosthesis can reduce the sense of disfigurement. If women were to obtain the full psychological benefit of wearing a breast prosthesis, they need to be informed about the available breast forms, have an opportunity to choose between them, and to be satisfied with their choice. In this study of 49 women, only 44% had had the opportunity to choose a prosthesis, 28% were dissatisfied with their prostheses, and 17% were still using temporary prostheses.

  20. Good results in postoperative and hematogenous deep infections of 89 stable total hip and knee replacements with retention of prosthesis and local antibiotics.

    PubMed

    Geurts, Jan A P; Janssen, Daniël M C; Kessels, Alfons G H; Walenkamp, Geert H I M

    2013-12-01

    Deep postoperative and hematogenous prosthesis infections may be treated with retention of the prosthesis, if the prosthesis is stable. How long the infection may be present to preclude a good result is unclear. We retrospectively studied 89 deep-infected stable prostheses from 69 total hip replacements and 20 total knee replacements. There were 83 early or delayed postoperative infections and 6 hematogenous. In the postoperative infections, treatment had started 12 days to 2 years after implantation. In the hematogenous infections, symptoms had been present for 6 to 9 days. The patients had been treated with debridement, prosthesis retention, systemic antibiotics, and local antibiotics: gentamicin-PMMA beads or gentamicin collagen fleeces. The minimum follow-up time was 1.5 years. We investigated how the result of the treatment had been influenced by the length of the period the infection was present, and by other variables such as host characteristics, infection stage, and type of bacteria. In postoperative infections, the risk of failure increased with a longer postoperative interval: from 0.2 (95% CI: 0.1-0.3) if the treatment had started ≥ 4 weeks postoperatively to 0.5 (CI: 0.2-0.8) if it had started at ≥ 8 weeks. The relative risk for success was 0.6 (CI: 0.3-0.95) if the treatment had started ≥ 8 weeks. In the hematogenous group, 5 of 6 infections had been treated successfully. A longer delay before the start of the treatment caused an increased failure rate, but this must be weighed against the advantage of keeping the prosthesis. We consider a failure rate of < 50% to be acceptable, and we therefore advocate keeping the prosthesis for up to 8 weeks postoperatively, and in hematogenous infections with a short duration of symptoms.

  1. Prosthetic joint infection caused by Pasteurella multocida: a case series and review of literature.

    PubMed

    Honnorat, Estelle; Seng, Piseth; Savini, Hélène; Pinelli, Pierre-Olivier; Simon, Fabrice; Stein, Andreas

    2016-08-20

    Pasteurella multocida is a well-recognized zoonotic agent following dog or cat bites or scratches. Nevertheless, prosthetic joint infection caused by P. multocida are rarely reported. We report here a series of six cases of prosthetic joint infection caused by P. multocida managed at a referral centre for the treatment of bone and joint infection in southern France. We also reviewed the 26 cases reported in literature. The mean age of our cases was 74 years [±8.2, range 63-85]. In majority of our cases (5 cases) were associated with knee prostheses and one case with a hip prosthesis. Most of cases occurred after cat or dog scratches or licks or contact. Diagnoses of prosthetic joint infection caused by P. multocida were made by positive cultures of surgical biopsies or needle aspiration. Mean time delay between prosthetic joint implantation and infection onset was 7.6 years (±5.12 years, range 2-17). Local inflammation, which occurred in all six cases, was the most frequent clinical symptom, followed by pain in five cases, fever and swollen joints in four cases, and a fistula with purulent discharge inside the wound in two cases. The mean time of antibiotic therapy was 8 months. Surgical treatment with prosthesis removal was performed in three cases. Six of our cases were in remission without apparent relapse at 3 years after end of treatment. Prosthetic joint infections caused by P. multocida usually occur after animal scratches or bites, but can occasionally occur after a short animal lick. These infections are usually resulting from a contiguous infection and localized in the knee. An early antibiotic therapy after surgical debridement could avoid prosthetic withdrawal, notably in elderly patients. Patients with prosthetic joints should be warned that animals are potential sources of serious infection and urgent medical advice should be sought if they are bitten or scratched.

  2. A Scandinavian experience of register collaboration: the Nordic Arthroplasty Register Association (NARA).

    PubMed

    Havelin, Leif I; Robertsson, Otto; Fenstad, Anne M; Overgaard, Søren; Garellick, Göran; Furnes, Ove

    2011-12-21

    The Nordic (Scandinavian) countries have had working arthroplasty registers for several years. However, the small numbers of inhabitants and the conformity within each country with respect to preferred prosthesis brands and techniques have limited register research. A collaboration called NARA (Nordic Arthroplasty Register Association) was started in 2007, resulting in a common database for Denmark, Norway, and Sweden with regard to hip replacements in 2008 and primary knee replacements in 2009. Finland joined the project in 2010. A code set was defined for the parameters that all registers had in common, and data were re-coded, within each national register, according to the common definitions. After de-identification of the patients, the anonymous data were merged into a common database. The first study based on this common database included 280,201 hip arthroplasties and the second, 151,814 knee arthroplasties. Kaplan-Meier and Cox multiple regression analyses, with adjustment for age, sex, and diagnosis, were used to calculate prosthesis survival, with any revision as the end point. In later studies, specific reasons for revision were also used as end points. We found differences among the countries concerning patient demographics, preferred surgical approaches, fixation methods, and prosthesis brands. Prosthesis survival was best in Sweden, where cement implant fixation was used more commonly than it was in the other countries. As the comparison of national results was one of the main initial aims of this collaboration, only parameters and data that all three registers could deliver were included in the database. Compared with each separate register, this combined register resulted in reduced numbers of parameters and details. In future collaborations of registers with a focus on comparing the performances of prostheses and articulations, we should probably include only the data needed specifically for the predetermined purposes, from registers that can deliver these data, rather than compiling all data from all registers that are willing to participate.

  3. Using Noncontingent Reinforcement to Increase Compliance with Wearing Prescription Prostheses

    ERIC Educational Resources Information Center

    Richling, Sarah M.; Rapp, John T.; Carroll, Regina A.; Smith, Jeanette N.; Nystedt, Aaron; Siewert, Brook

    2011-01-01

    We evaluated the effects of noncontingent reinforcement (NCR) on compliance with wearing foot orthotics and a hearing aid with 2 individuals. Results showed that NCR increased the participants' compliance with wearing prescription prostheses to 100% after just a few 5-min sessions, and the behavior change was maintained during lengthier sessions.…

  4. [Image processing system of visual prostheses based on digital signal processor DM642].

    PubMed

    Xie, Chengcheng; Lu, Yanyu; Gu, Yun; Wang, Jing; Chai, Xinyu

    2011-09-01

    This paper employed a DSP platform to create the real-time and portable image processing system, and introduced a series of commonly used algorithms for visual prostheses. The results of performance evaluation revealed that this platform could afford image processing algorithms to be executed in real time.

  5. Composite Materials for Maxillofacial Prostheses.

    DTIC Science & Technology

    1983-02-01

    the most promise for producing elastomeric-shelled microcapsules containing an inert liquid. While much of the diverse field of microencapsulation is...Processes and Applications, Chicago, 28 August 1973. 11. Gutchko, M. H., Microcapsules and Microencapsulation Techniques. Noyes Data Corporation, Park Ridge...necesaryv and identify by block number) * MAXILLOFACIAL PROSTHESES; PROSTHETIC MATERIALS: MICROCAPSULES : * SOFT FILLERS; ELASTOMER COMPOSITES 2L

  6. Computational comparison of aortic root stresses in presence of stentless and stented aortic valve bio-prostheses.

    PubMed

    Nestola, M G C; Faggiano, E; Vergara, C; Lancellotti, R M; Ippolito, S; Antona, C; Filippi, S; Quarteroni, A; Scrofani, R

    2017-02-01

    We provide a computational comparison of the performance of stentless and stented aortic prostheses, in terms of aortic root displacements and internal stresses. To this aim, we consider three real patients; for each of them, we draw the two prostheses configurations, which are characterized by different mechanical properties and we also consider the native configuration. For each of these scenarios, we solve the fluid-structure interaction problem arising between blood and aortic root, through Finite Elements. In particular, the Arbitrary Lagrangian-Eulerian formulation is used for the numerical solution of the fluid-dynamic equations and a hyperelastic material model is adopted to predict the mechanical response of the aortic wall and the two prostheses. The computational results are analyzed in terms of aortic flow, internal wall stresses and aortic wall/prosthesis displacements; a quantitative comparison of the mechanical behavior of the three scenarios is reported. The numerical results highlight a good agreement between stentless and native displacements and internal wall stresses, whereas higher/non-physiological stresses are found for the stented case.

  7. A system verification platform for high-density epiretinal prostheses.

    PubMed

    Chen, Kuanfu; Lo, Yi-Kai; Yang, Zhi; Weiland, James D; Humayun, Mark S; Liu, Wentai

    2013-06-01

    Retinal prostheses have restored light perception to people worldwide who have poor or no vision as a consequence of retinal degeneration. To advance the quality of visual stimulation for retinal implant recipients, a higher number of stimulation channels is expected in the next generation retinal prostheses, which poses a great challenge to system design and verification. This paper presents a system verification platform dedicated to the development of retinal prostheses. The system includes primary processing, dual-band power and data telemetry, a high-density stimulator array, and two methods for output verification. End-to-end system validation and individual functional block characterization can be achieved with this platform through visual inspection and software analysis. Custom-built software running on the computers also provides a good way for testing new features before they are realized by the ICs. Real-time visual feedbacks through the video displays make it easy to monitor and debug the system. The characterization of the wireless telemetry and the demonstration of the visual display are reported in this paper using a 256-channel retinal prosthetic IC as an example.

  8. Clinical Management of Implant Prostheses in Patients with Bruxism

    PubMed Central

    Komiyama, Osamu; Lobbezoo, Frank; De Laat, Antoon; Iida, Takashi; Kitagawa, Tsuyoshi; Murakami, Hiroshi; Kato, Takao; Kawara, Misao

    2012-01-01

    There is general agreement that excessive stress to the bone-implant interface may result in implant overload and failure. Early failure of the implant due to excessive loading occurs shortly after uncovering the implant. Excess load on a final restoration after successful implant integration can result in physical failure of the implant structure. Many clinicians believe that overload of dental implants is a risk factor for vertical peri-implant bone loss and/or may be detrimental for the suprastructure in implant prostheses. It has been documented that occlusal parafunction, such as, bruxism (tooth grinding and clenching) affects the outcome of implant prostheses, but there is no evidence for a causal relation between the failures and overload of dental implants. In spite of this lack of evidence, often metal restorations are preferred instead of porcelain for patients in whom bruxism is presumed on the basis of tooth wear. The purpose of this paper is to discuss the importance of the occlusal scheme used in implant restorations for implant longevity and to suggest a clinical approach and occlusal materials for implant prostheses in order to prevent complications related to bruxism. PMID:22701484

  9. A Morlet wavelet signal analysis with a Daubechies filter for the wear assessment of hip prostheses coated with diamond-like carbon by triboadhesion.

    PubMed

    Rodríguez-Lelis, Jose Maria; Mata, Dagoberto Tolosa; Vargas-Treviño, Marciano; Navarro-Torres, Jose; Piña-Piña, Gilberto; Abundez-Pliego, Arturo

    2010-08-01

    In the present work, based on high frequency wavelet analysis of dynamic signals of mechanical systems, a multiple-resolution wavelet analysis is carried out, to the signal obtained from an accelerometer mounted on the structure of a hip prosthesis wearing test device. The prostheses employed had a femoral head made of aluminum oxide and the acetabular cup of ultra-high-molecular-weight polyethylene. The first two aluminum oxide femoral heads were coated with diamond-like carbon and a third one was tested without coating and used as a reference. The coating was carried out by triboadhesion. Tests results showed that maximum vibration amplitude reached after 32 hr for the coated prostheses was 0.2 g. The noncoated prosthesis amplitude presented was 0.75 g in the same time interval. These values were attributed to wear damage on the surface of the prostheses, indicating that thin film DLC coating caused an increase of stiffness on the surface and therefore an increase in wear resistance approximately of 314%.

  10. Bone-anchored titanium implants for auricular rehabilitation: case report and review of literature.

    PubMed

    Gumieiro, Emne Hammoud; Dib, Luciano Lauria; Jahn, Ricardo Schmitutz; Santos Junior, João Ferreira dos; Nannmark, Ulf; Granström, Gösta; Abrahão, Márcio

    2009-01-01

    Osseointegrated implants have acquired an important role in the prosthetic rehabilitation of patients with craniofacial defects. The main indications are lack of local tissue for autogenous reconstruction, previous reconstruction failure and selection of this technique by the patient. This paper presents a clinical case and discusses indications and advantages of the osseointegrated implant technique for retention of auricular prostheses. Case report, Universidade Federal de São Paulo (UNIFESP). A female patient received three auricular implants after surgical resection of a hemangioma in her left ear. The time taken for osseointegration of the temporal bone was three months. After fabrication of the implant-retained auricular prosthesis, the patient was monitored for 12 months. The clinical parameters evaluated showed good postoperative healing, healthy peri-implant tissue, good hygiene and no loss of implants. Good hygiene combined with thin and immobile peri-implant soft tissues resulted in minimal complications. Craniofacial implant integration appears to be site-dependent; increasing age affects osseointegration in the temporal bone. The frequency of adverse skin reactions in peri-implant tissues is generally low. The surgical technique for rehabilitation using implant-retained auricular prostheses seems to be simple. It is associated with low rates of adverse skin reactions and long-term complications. Prostheses anchored by osseointegrated implants seem to provide better retention than do prostheses supported on spectacle frames, less risk of discoloration through the use of adhesives and better esthetic results than do prostheses anchored in the surgical cavity.

  11. Toward Optimal Target Placement for Neural Prosthetic Devices

    PubMed Central

    Cunningham, John P.; Yu, Byron M.; Gilja, Vikash; Ryu, Stephen I.; Shenoy, Krishna V.

    2008-01-01

    Neural prosthetic systems have been designed to estimate continuous reach trajectories (motor prostheses) and to predict discrete reach targets (communication prostheses). In the latter case, reach targets are typically decoded from neural spiking activity during an instructed delay period before the reach begins. Such systems use targets placed in radially symmetric geometries independent of the tuning properties of the neurons available. Here we seek to automate the target placement process and increase decode accuracy in communication prostheses by selecting target locations based on the neural population at hand. Motor prostheses that incorporate intended target information could also benefit from this consideration. We present an optimal target placement algorithm that approximately maximizes decode accuracy with respect to target locations. In simulated neural spiking data fit from two monkeys, the optimal target placement algorithm yielded statistically significant improvements up to 8 and 9% for two and sixteen targets, respectively. For four and eight targets, gains were more modest, as the target layouts found by the algorithm closely resembled the canonical layouts. We trained a monkey in this paradigm and tested the algorithm with experimental neural data to confirm some of the results found in simulation. In all, the algorithm can serve not only to create new target layouts that outperform canonical layouts, but it can also confirm or help select among multiple canonical layouts. The optimal target placement algorithm developed here is the first algorithm of its kind, and it should both improve decode accuracy and help automate target placement for neural prostheses. PMID:18829845

  12. Differences of oral health conditions between adults and older adults: A census in a Southern Brazilian city.

    PubMed

    Boscato, Noeli; Schuch, Helena S; Grasel, Claudia E; Goettems, Marilia L

    2016-09-01

    To assess differences in the oral diseases/conditions between adults and older adults. A cross-sectional study was carried out with all adults and older adults in Luzerna, South Brazil (n = 569). Clinical data included use of and need for dental prostheses; number of decayed, missing and filled teeth; and temporomandibular disorder. Differences between adults and older adults were evaluated using χ(2) -tests. Associations between independent variables and the use of and need for dental prostheses were determined using Poisson regression analyses (P < 0.05). Increased number of decayed, missing and filled teeth, use of and need for dental prostheses, higher use of complete dentures, and fewer temporomandibular disorder signs and symptoms were observed in older adults. After adjustments, lower social class (P = 0.001) and unmarried status (P = 0.05) were associated with greater need for prosthetic rehabilitation. Women (P = 0.02), older individuals (P < 0.001) and those of lower socioeconomic status (P = 0.001) had a higher risk of using prostheses. A significant difference of oral conditions between adults and older adults was observed. The frequency of use of and need for dental prostheses was higher for older adults, although they had reported lower frequency of temporomandibular disorder. Women, married and individuals of higher socioeconomic status showed better oral health conditions. Geriatr Gerontol Int 2016; 16: 1014-1020. © 2015 Japan Geriatrics Society.

  13. 3D-printed upper limb prostheses: a review.

    PubMed

    Ten Kate, Jelle; Smit, Gerwin; Breedveld, Paul

    2017-04-01

    This paper aims to provide an overview with quantitative information of existing 3D-printed upper limb prostheses. We will identify the benefits and drawbacks of 3D-printed devices to enable improvement of current devices based on the demands of prostheses users. A review was performed using Scopus, Web of Science and websites related to 3D-printing. Quantitative information on the mechanical and kinematic specifications and 3D-printing technology used was extracted from the papers and websites. The overview (58 devices) provides the general specifications, the mechanical and kinematic specifications of the devices and information regarding the 3D-printing technology used for hands. The overview shows prostheses for all different upper limb amputation levels with different types of control and a maximum material cost of $500. A large range of various prostheses have been 3D-printed, of which the majority are used by children. Evidence with respect to the user acceptance, functionality and durability of the 3D-printed hands is lacking. Contrary to what is often claimed, 3D-printing is not necessarily cheap, e.g., injection moulding can be cheaper. Conversely, 3D-printing provides a promising possibility for individualization, e.g., personalized socket, colour, shape and size, without the need for adjusting the production machine. Implications for rehabilitation Upper limb deficiency is a condition in which a part of the upper limb is missing as a result of a congenital limb deficiency of as a result of an amputation. A prosthetic hand can restore some of the functions of a missing limb and help the user in performing activities of daily living. Using 3D-printing technology is one of the solutions to manufacture hand prostheses. This overview provides information about the general, mechanical and kinematic specifications of all the devices and it provides the information about the 3D-printing technology used to print the hands.

  14. CNC-milled titanium frameworks supported by implants in the edentulous jaw: a 10-year comparative clinical study.

    PubMed

    Örtorp, Anders; Jemt, Torsten

    2012-03-01

    No long-term clinical studies covering more than 5 years are available on Computer Numeric Controlled (CNC) milled titanium frameworks. To evaluate and compare the clinical and radiographic performance of implant-supported prostheses provided with CNC titanium frameworks in the edentulous jaw with prostheses with cast gold-alloy frameworks during the first 10 years of function. Altogether, 126 edentulous patients were by random provided with 67 prostheses with titanium frameworks (test) in 23 maxillas and 44 mandibles, and with 62 prostheses with gold-alloy castings (control) in 31 maxillas and 31 mandibles. Clinical and radiographic 10-year data were collected for the groups and statistically compared on patient level. The 10-year prosthesis and implant cumulative survival rate was 95.6% compared with 98.3%, and 95.0% compared with 97.9% for test and control groups, respectively (p > .05). No implants were lost after 5 years of follow-up. Smokers lost more implants than nonsmokers after 5 years of follow-up (p < .01). Mean marginal bone loss in the test group was 0.7 mm (SD 0.61) and 0.7 mm (SD 0.85) in the maxilla and mandible, with similar pattern in the control group (p > .05), respectively. One prosthesis was lost in each group due to loss of implants, and one prosthesis failed due to framework fracture in the test group. Two metal fractures were registered in each group. More appointments of maintenance were needed for the prostheses in the maxilla compared with those in the mandible (p < .001). The frequency of complications was low with similar clinical and radiological performance for both groups during 10 years. CNC-milled titanium frameworks are a viable alternative to gold-alloy castings for restoring patients with implant-supported prostheses in the edentulous jaw. © 2009 Wiley Periodicals, Inc.

  15. Oral health-related quality of life and masticatory function after conventional prosthetic treatment: A cohort follow-up study.

    PubMed

    Palomares, Teresa; Montero, Javier; Rosel, Eva M; Del-Castillo, Ramón; Rosales, Juan I

    2018-05-01

    The impact of conventional prosthetic treatment on both the objective and subjective assessments of mastication as well as on well-being is unclear. The purpose of this clinical study was to compare the impact on oral health-related quality of life and masticatory function in participants treated with conventional dental prostheses. A total of 72 patients requiring prosthetic rehabilitation were enrolled by referral from the Faculty of Dentistry at the University of Granada, Spain. At baseline, demographic, behavioral, and clinical (prosthetic status, occlusal units) data were collected. In addition, the scores for quality of life, oral satisfaction, masticatory ability (Leake index), and masticatory performance (after 5, 10, and 15 cycles of bicolored chewing gum) were obtained. These records were obtained again at 6 to 8 weeks after insertion of the prostheses. The findings revealed that patients treated with fixed prostheses had better quality of life and better masticatory function than patients treated with removable prostheses. This result was even more pronounced for those treated with complete dentures. For all items, most of the treated patients improved the quality of life (average, 8.6 of the 4 items), although only between 5% and 15% of patients, especially those with a removable prosthesis, commented on functional impact after receiving treatment. Generally, masticatory performance was improved between 7% and 18% and was highly correlated not only with the number of natural teeth (r=0.61) and occlusal units (r=0.51) but also with subjective variables such as mastication satisfaction (r=0.31), impact on quality of life (r=0.30), or masticatory ability (r=0.30). Treatment with fixed prostheses achieved better results regarding quality of life, oral satisfaction, and masticatory function than treatment with removable prostheses. A moderate but significant correlation exists between the objective and subjective assessments of the masticatory functions. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  16. [Rehabilitation by hollow obturator prosthesis immediately after total maxillectomy for malignant tumor].

    PubMed

    Li, Xiao-ye; Yan, Ai-hui; Hao, Shuai; Li, Wei; Jiang, Xue-jun; Lu, Li; Qin, Xing-jun; Yan, Hai-xin

    2011-05-01

    The feasibility and clinical effects of hollow obturator prosthesis for the repair of maxillofacial defect immediately after maxillectomy for cancer were assessed. Thirteen patients with T3-4aN0M0 maxillary neoplasm were treated by the prostheses immediately after maxillectomy. According to the 3D-CT reconstruction of nasal sinus, the 3D stereoscopic prototype was constructed before the surgery. Simulating surgery with Surgicare 5.0 software and then the prosthesis 3D stereoscopic model was shaped. The prosthesis was made quickly and precisely with methacrylate resins according to the model and the print mold before surgery, with supplementary tooth at the bottom of prosthesis. In the surgery, the prosthesis was installed instantly after maxillectomy. The patients were followed up at 1, 3 and 6 month after the surgery, respectively. The facial features and the pronunciation clarity were examined and the questionnaires were carried out in the patients, with comparation by paired t-test. The hollow obturator prosthesis would be replaced by permanent prosthesis made of methacrylate resins at 6 month after the surgery. The hollow obturator prostheses were installed accurately and maxillofacial defects were repaired immediately after maxillectomy in the 13 patients. Postoperative follow-up showed there were significant differences in eyeball sagging (t = 4.67, P < 0.05), mid-facial region collapse (t = 5.67, P < 0.05), and pronunciation clarity (t = 16.38, P < 0.05) between patients with and without prostheses. Questionnaires showed that all the patients were satisfied with the retention of prostheses, the improvement of appearance, the improvement of the symptom of water choking and speech definition. Six months after the surgery, the hollow obturator prostheses were replaced smoothly by permanent prostheses in 11 of the 13 patients. The precise and instant repair of maxillofacial defect by prosthesis after maxillectomy can improve survival quality of patient.

  17. Reduction of metal artifacts from hip prostheses on CT images of the pelvis: value of iterative reconstructions.

    PubMed

    Morsbach, Fabian; Bickelhaupt, Sebastian; Wanner, Guido A; Krauss, Andreas; Schmidt, Bernhard; Alkadhi, Hatem

    2013-07-01

    To assess the value of iterative frequency split-normalized (IFS) metal artifact reduction (MAR) for computed tomography (CT) of hip prostheses. This study had institutional review board and local ethics committee approval. First, a hip phantom with steel and titanium prostheses that had inlays of water, fat, and contrast media in the pelvis was used to optimize the IFS algorithm. Second, 41 consecutive patients with hip prostheses who were undergoing CT were included. Data sets were reconstructed with filtered back projection, the IFS algorithm, and a linear interpolation MAR algorithm. Two blinded, independent readers evaluated axial, coronal, and sagittal CT reformations for overall image quality, image quality of pelvic organs, and assessment of pelvic abnormalities. CT attenuation and image noise were measured. Statistical analysis included the Friedman test, Wilcoxon signed-rank test, and Levene test. Ex vivo experiments demonstrated an optimized IFS algorithm by using a threshold of 2200 HU with four iterations for both steel and titanium prostheses. Measurements of CT attenuation of the inlays were significantly (P < .001) more accurate for IFS when compared with filtered back projection. In patients, best overall and pelvic organ image quality was found in all reformations with IFS (P < .001). Pelvic abnormalities in 11 of 41 patients (27%) were diagnosed with significantly (P = .002) higher confidence on the basis of IFS images. CT attenuation of bladder (P < .001) and muscle (P = .043) was significantly less variable with IFS compared with filtered back projection and linear interpolation MAR. In comparison with that of FBP and linear interpolation MAR, noise with IFS was similar close to and far from the prosthesis (P = .295). The IFS algorithm for CT image reconstruction significantly reduces metal artifacts from hip prostheses, improves the reliability of CT number measurements, and improves the confidence for depicting pelvic abnormalities.

  18. Fracture analysis of randomized implant-supported fixed dental prostheses

    PubMed Central

    Esquivel-Upshaw, Josephine F.; Mehler, Alex; Clark, Arthur E.; Neal, Dan; Anusavice, Kenneth J.

    2014-01-01

    Objective Fractures of posterior fixed dental all-ceramic prostheses can be caused by one or more factors including prosthesis design, flaw distribution, direction and magnitude of occlusal loading, and nature of supporting infrastructure (tooth root/implant), and presence of adjacent teeth. This clinical study of implant-supported, all-ceramic fixed dental prostheses, determined the effects of (1) presence of a tooth distal to the most distal retainer; (2) prosthesis loading either along the non-load bearing or load bearing areas; (3) presence of excursive contacts or maximum intercuspation contacts in the prosthesis; and (4) magnitude of bite force on the occurrence of veneer ceramic fracture. Methods 89 implant-supported FDPs were randomized as either a three-unit posterior metal-ceramic (Au-Pd-Ag alloy and InLine POM, Ivoclar, Vivadent) FDP or a ceramic-ceramic (ZirCAD and ZirPress, Ivoclar, Vivadent) FDP. Two implants (Osseospeed, Dentsply) and custom abutments (Atlantis, Dentsply) supported these FDPs, which were cemented with resin cement (RelyX Universal Cement). Baseline photographs were made with markings of teeth from maximum intercuspation (MI) and excursive function. Patients were recalled at 6 months and 1 to 3 years. Fractures were observed, their locations recorded, and images compared with baseline photographs of occlusal contacts. Conclusion No significant relationship exists between the occurrence of fracture and: (1) the magnitude of bite force; (2) a tooth distal to the most distal retainer; and (3) contacts in load-bearing or non-load-bearing areas. However, there was a significantly higher likelihood of fracture in areas with MI contacts only. Clinical Significance This clinical study demonstrates that there is a need to evaluate occlusion differently with implant-supported prostheses than with natural tooth supported prostheses because of the absence of a periodontal ligament. Implant supported prostheses should have minimal occlusion and lighter contacts than ones supported by natural dentition. PMID:25016139

  19. Porps, torps, and homografts in tympanoplasty.

    PubMed

    Gillanders, D A; Cambon, K G; Doyle, P J

    1980-04-01

    A brief review of the use of plastique prostheses in ossiculoplasty, as well as the use of homograft tympanic membranes along with our experience is reported. Plastipore prostheses have been found to be useful, and their continued use is advocated. Homograft tympanic membranes are useful in repairing those ears which have undergone extensive damage to the tympanic membrane and ossicles.

  20. Dental claims in the Swedish Patient Insurance Scheme.

    PubMed

    René, N; Owall, B; Cronström, R

    1991-06-01

    The Swedish Patient Insurance Scheme covers treatment injuries and guarantees the replacement of failed removable prostheses for 1 year and fixed prostheses for 2 years after fitting. In this paper, 573 dental cases are analysed for a 3-month period in 1986, during which crowns and bridges formed the vast majority of failed treatments that were reported.

  1. Manufacturing Implant Supported Auricular Prostheses by Rapid Prototyping Techniques

    PubMed Central

    Karatas, Meltem Ozdemir; Cifter, Ebru Demet; Ozenen, Didem Ozdemir; Balik, Ali; Tuncer, Erman Bulent

    2011-01-01

    Maxillofacial prostheses are usually fabricated on the models obtained following the impression procedures. Disadvantages of conventional impression techniques used in production of facial prosthesis are deformation of soft tissues caused by impression material and disturbance of the patient due to. Additionally production of prosthesis by conventional methods takes longer time. Recently, rapid prototyping techniques have been developed for extraoral prosthesis in order to reduce these disadvantages of conventional methods. Rapid prototyping technique has the potential to simplify the procedure and decrease the laboratory work required. It eliminates the need for measurement impression procedures and preparation of wax model to be performed by prosthodontists themselves In the near future this technology will become a standard for fabricating maxillofacial prostheses. PMID:21912504

  2. Perioperative and rehabilitation outcome after lower-limb amputation in elderly Chinese patients in Hong Kong.

    PubMed

    Leung, H B; Wong, W C; Wu, F C J; Guerin, J S

    2004-06-01

    Major amputation of the lower limb is considered the last resort when limb salvage is impossible. The aim of this study is to determine the morbidity, mortality, and rehabilitation outcome of patients that underwent a lower-limb amputation. A retrospective cohort study was conducted among 100 elderly patients who underwent a total of 120 lower-limb amputations in a regional hospital in Hong Kong from 1996 to 2001. The mean age of the amputees was 77.9 years; 58 were female. 95% of the amputations were performed because of infection with or without vascular compromise; 55 transfemoral and 60 transtibial amputations contributed 96% of the case mix. Some 43% of patients experienced early complications and 12% required re-amputation. The early (30-day) mortality rate was 15%. Only 55% of the amputees survived after 4 years. A 44% return-home rate was achieved. However, only 11% of the amputees could walk without help from other people. Although prostheses were issued to 42% of the survivors, compliance was only 53%; 24% of the survivors lost their remaining leg within 2 years. The outcome of major lower-extremity amputation remains poor. Efforts should be made to retain these limbs. When it is proven impossible, one should strive to preserve the knee joint whenever feasible.

  3. Wear of ultra-high molecular weight polyethylene against damaged and undamaged stainless steel and diamond-like carbon-coated counterfaces.

    PubMed

    Firkins, P; Hailey, J L; Fisher, J; Lettington, A H; Butter, R

    1998-10-01

    The wear of ultra-high molecular weight polyethylene (UHMWPE) in artificial joints and the resulting wear debris-induced osteolysis remains a major clinical concern in the orthopaedic sector. Third-body damage of metallic femoral heads is often cited as a cause of accelerated polyethylene wear, and the use of ceramic femoral heads in the hip is gaining increasing favour. In the knee prostheses and for smaller diameter femoral heads, the application of hard surface coatings, such as diamond-like carbon, is receiving considerable attention. However, to date, there has been little or no investigation of the tribology of these coatings in simulated biological environments. In this study, diamond-like carbon (DLC) has been compared to stainless steel in its undamaged form and following simulated third-body damage. The wear of UHMWPE was found to be similar when sliding against undamaged DLC and stainless steel counterfaces. DLC was found to be much more damage resistant than DLC. Under test conditions that simulate third-body damage to the femoral head, the wear of UHMWPE was seven times lower against DLC than against stainless steel (P < 0.05). The study shows DLC has considerable potential as a femoral bearing surface in artificial joints.

  4. Does Extracellular DNA Production Vary in Staphylococcal Biofilms Isolated From Infected Implants versus Controls?

    PubMed

    Zatorska, Beata; Groger, Marion; Moser, Doris; Diab-Elschahawi, Magda; Lusignani, Luigi Segagni; Presterl, Elisabeth

    2017-08-01

    Prosthetic implant infections caused by Staphylococcus aureus and epidermidis are major challenges for early diagnosis and treatment owing to biofilm formation on the implant surface. Extracellular DNA (eDNA) is actively excreted from bacterial cells in biofilms, contributing to biofilm stability, and may offer promise in the detection or treatment of such infections. (1) Does DNA structure change during biofilm formation? (2) Are there time-dependent differences in eDNA production during biofilm formation? (3) Is there differential eDNA production between clinical and control Staphylococcal isolates? (4) Is eDNA production correlated to biofilm thickness? We investigated eDNA presence during biofilm formation in 60 clinical and 30 control isolates of S aureus and S epidermidis. The clinical isolates were isolated from patients with infections of orthopaedic prostheses and implants: 30 from infected hip prostheses and 30 from infected knee prostheses. The control isolates were taken from healthy volunteers who had not been exposed to antibiotics and a hospital environment during the previous 3 and 12 months, respectively. Control S epidermidis was isolated from the skin of the antecubital fossa, and control S aureus was isolated from the nares. For the biofilm experiments the following methods were used to detect eDNA: (1) fluorescent staining with 4',6-diamidino-2-phenylindole (DAPI), (2) eDNA extraction using a commercial kit, and (3) confocal laser scanning microscopy for 24-hour biofilm observation using propidium iodide and concanavalin-A staining; TOTO ® -1 and SYTO ® 60 staining were used for observation and quantification of eDNA after 6 and 24 hours of biofilm formation. Additionally antibiotic resistance was described. eDNA production as observed by confocal laser scanning microscopy was greater in clinical isolates than controls (clinical isolates mean ± SD: 1.84% ± 1.31%; control mean ± SD: 1.17% ± 1.37%; p < 0.005) after 6 hours of biofilm formation. After 24 hours, the amount of eDNA was greater in biofilms of S epidermidis than in biofilms of S aureus (S aureus mean ± SD: 1.35% ± 2.0%; S epidermidis mean ± SD: 6.42% ± 10.6%; p < 0.05). Clinical isolates of S aureus and S epidermidis produced more eDNA than control isolates at 6 hours of biofilm formation. The extraction method also showed that clinical isolates produced substantially greater amounts of eDNA than controls. S aureus and S epidermidis exhibit a differential production of DNA with time. Clinical isolates associated with implant infections produce greater amounts of eDNA than controls. Future research might focus on the diagnostic value of eDNA as a surrogate laboratory marker for biofilm formation in implant infections. eDNA should be considered as a potential future diagnostic tool or even a possible target to modify biofilms for successful treatment of biofilm-associated infections.

  5. Tracheostomy cannulas and voice prosthesis

    PubMed Central

    Kramp, Burkhard; Dommerich, Steffen

    2011-01-01

    Cannulas and voice prostheses are mechanical aids for patients who had to undergo tracheotomy or laryngectomy for different reasons. For better understanding of the function of those artificial devices, first the indications and particularities of the previous surgical intervention are described in the context of this review. Despite the established procedure of percutaneous dilatation tracheotomy e.g. in intensive care units, the application of epithelised tracheostomas has its own position, especially when airway obstruction is persistent (e.g. caused by traumata, inflammations, or tumors) and a longer artificial ventilation or special care of the patient are required. In order to keep the airways open after tracheotomy, tracheostomy cannulas of different materials with different functions are available. For each patient the most appropriate type of cannula must be found. Voice prostheses are meanwhile the device of choice for rapid and efficient voice rehabilitation after laryngectomy. Individual sizes and materials allow adaptation of the voice prostheses to the individual anatomical situation of the patients. The combined application of voice prostheses with HME (Head and Moisture Exchanger) allows a good vocal as well as pulmonary rehabilitation. Precondition for efficient voice prosthesis is the observation of certain surgical principles during laryngectomy. The duration of the prosthesis mainly depends on material properties and biofilms, mostly consisting of funguses and bacteries. The quality of voice with valve prosthesis is clearly superior to esophagus prosthesis or electro-laryngeal voice. Whenever possible, tracheostoma valves for free-hand speech should be applied. Physicians taking care of patients with speech prostheses after laryngectomy should know exactly what to do in case the device fails or gets lost. PMID:22073098

  6. Effect of alignment changes on socket reaction moments while walking in transtibial prostheses with energy storage and return feet

    PubMed Central

    Kobayashi, Toshiki; Arabian, Adam K.; Orendurff, Michael S.; Rosenbaum-Chou, Teri G.; Boone, David A.

    2014-01-01

    Background Energy storage and return feet are designed for active amputees. However, little is known about the socket reaction moments in transtibial prostheses with energy storage and return feet. The aim of this study was to investigate the effect of alignment changes on the socket reaction moments during gait while using the energy storage and return feet. Methods A Smart Pyramid™ was used to measure the socket reaction moments in 10 subjects with transtibial prostheses while walking under 25 alignment conditions, including a nominal alignment (as defined by conventional clinical methods), as well as angle malalignments of 2°, 4° and 6° (flexion, extension, abduction, and adduction) and translation malalignments of 5mm, 10mm and 15mm (anterior, posterior, lateral, and medial) referenced from the nominal alignment. The socket reaction moments of the nominal alignment were compared with each malalignment. Findings Both coronal and sagittal alignment changes demonstrated systematic effects on the socket reaction moments. In the sagittal plane, angle and translation alignment changes demonstrated significant differences (P<0.05) in the minimum moment, the moment at 45% of stance and the maximum moment for some comparisons. In the coronal plane, angle and translation alignment changes demonstrated significant differences (P<0.05) in the moment at 30% and 75% of stance for all comparisons. Interpretation The alignment may have systematic effects on the socket reaction moments in transtibial prostheses with energy storage and return feet. The socket reaction moments could potentially be a useful biomechanical parameter to evaluate the alignment of the transtibial prostheses. PMID:24315709

  7. In vivo implant fixation of carbon fiber-reinforced PEEK hip prostheses in an ovine model.

    PubMed

    Nakahara, Ichiro; Takao, Masaki; Bandoh, Shunichi; Bertollo, Nicky; Walsh, William R; Sugano, Nobuhiko

    2013-03-01

    Carbon fiber-reinforced polyetheretherketone (CFR/PEEK) is theoretically suitable as a material for use in hip prostheses, offering excellent biocompatibility, mechanical properties, and the absence of metal ions. To evaluate in vivo fixation methods of CFR/PEEK hip prostheses in bone, we examined radiographic and histological results for cementless or cemented CFR/PEEK hip prostheses in an ovine model with implantation up to 52 weeks. CFR/PEEK cups and stems with rough-textured surfaces plus hydroxyapatite (HA) coatings for cementless fixation and CFR/PEEK cups and stems without HA coating for cement fixation were manufactured based on ovine computed tomography (CT) data. Unilateral total hip arthroplasty was performed using cementless or cemented CFR/PEEK hip prostheses. Five cementless cups and stems and six cemented cups and stems were evaluated. On the femoral side, all cementless stems demonstrated bony ongrowth fixation and all cemented stems demonstrated stable fixation without any gaps at both the bone-cement and cement-stem interfaces. All cementless cases and four of the six cemented cases showed minimal stress shielding. On the acetabular side, two of the five cementless cups demonstrated bony ongrowth fixation. Our results suggest that both cementless and cemented CFR/PEEK stems work well for fixation. Cup fixation may be difficult for both cementless and cemented types in this ovine model, but bone ongrowth fixation on the cup was first seen in two cementless cases. Cementless fixation can be achieved using HA-coated CFR/PEEK implants, even under load-bearing conditions. Copyright © 2012 Orthopaedic Research Society.

  8. Immediate loading of implants placed in patients with untreated periodontal disease: a 5-year prospective cohort study.

    PubMed

    Maló, Paulo; Nobre, Miguel de Araújo; Lopes, Armando; Ferro, Ana; Gravito, Inês

    2014-01-01

    To report the 5-year outcome of immediately loaded dental implants in patients with untreated periodontal disease. This prospective cohort study included 103 consecutive patients (51 females and 52 males) with an average age of 52 years (range: 22 to 80 years) who were rehabilitated with 380 implants supporting 145 prostheses in both jaws (40 single; 33 partial and 72 complete rehabilitations). The implants were inserted in patients with active and untreated periodontitis. The patients did not receive any previous periodontal treatment before implant surgery, except for an oral hygiene session immediately before the implant surgery. In maintenance (every 6 months) patients received periodontal treatment as needed. Outcome measures were: prostheses failures; implant failures; complications; and marginal bone level changes. Fifteen patients dropped out of the study (14.6%). Two patients lost two implants (FDI positions nos.12 and 42), rendering a cumulative survival rate of 97.9% and 99.4% at 5 years of followup using the patient and implant as unit of analysis, respectively. The average (standard deviation) marginal bone resorption was 0.71 mm (0.42 mm) at 5 years. Mechanical complications occurred in 14 patients, consisting of prostheses fractures (10 provisional prostheses and 4 definitive prostheses). Thirteen implants (3.9%) in 13 patients (14.8%) presented peri-implant pathology. Within the limitations of this study, it is possible to conclude that the rehabilitation of patients with untreated periodontitis using immediately loaded dental implants is feasible in the medium-term, when periodontal therapy is provided after rehabilitation and the patients are regularly maintained.

  9. Investigation of firing temperature variation in ovens for ceramic-fused-to-metal dental prostheses using swept source optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Todor, Raluca; Negrutiu, Meda-Lavinia; Sinescu, Cosmin; Topala, Florin Ionel; Bradu, Adrian; Duma, Virgil-Florin; Romînu, Mihai; Podoleanu, Adrian G.

    2018-03-01

    One of the most common fabrication techniques for dental ceramics is sintering, a process of heating of the ceramic to ensure densification. This occurs by viscous flow when the firing temperature is reached. Acceptable restorations require the alloy and ceramic to be chemically, thermally, mechanically, and aesthetically compatible. Thermal and mechanical compatibility include a fusing temperature of ceramic that does not cause distortion of the metal substructure. Decalibration of ovens used for firing of the ceramic layers for metal ceramic dental prostheses leads to stress and cracks in the veneering material, and ultimately to the failure of the restoration. 25 metal ceramic prostheses were made for this study. They were divided in five groups, each sintered at a different temperature: a group at the temperature prescribed by the producer, two groups at lower and two groups at higher temperatures set in the ceramic oven. An established noninvasive biomedical imaging method, swept source (SS) optical coherence tomography (OCT) was employed, in order to evaluate the modifications induced when using temperatures different from those prescribed for firing the samples. A quantitative assessment of the probes is performed by en-face OCT images, taken at constant depths inside the samples. The differences in granulation, thus in reflectivity allow for extracting rules-of-thumb to evaluate fast, by using only the prostheses currently produced the current calibration of the ceramic oven. OCT imaging can allow quick identification of the oven decalibration, to avoid producing dental prostheses with defects.

  10. The Influence of Artificial Cervical Disc Prosthesis Height on the Cervical Biomechanics: A Finite Element Study.

    PubMed

    Yuan, Wei; Zhang, Haiping; Zhou, Xiaoshu; Wu, Weidong; Zhu, Yue

    2018-05-01

    Artificial cervical disc replacement is expected to maintain normal cervical biomechanics. At present, the effect of the Prestige LP prosthesis height on cervical biomechanics has not been thoroughly studied. This finite element study of the cervical biomechanics aims to predict how the parameters, like range of motion (ROM), adjacent intradiscal pressure, facet joint force, and bone-implant interface stress, are affected by different heights of Prestige LP prostheses. The finite element model of intact cervical spine (C3-C7) was obtained from our previous study, and the model was altered to implant Prestige LP prostheses at the C5-C6 level. The effects of the height of 5, 6, and 7 mm prosthesis replacement on ROM, adjacent intradiscal pressure, facet joint force, as well as the distribution of bone-implant interface stress were examined. ROM, adjacent intradiscal pressure, and facet joint force increased with the prosthesis height, whereas ROM and facet joint force decreased at C5-C6. The maximal stress on the inferior surface of the prostheses was greater than that on the superior surface, and the stresses increased with the prosthesis height. The biomechanical changes were slightly affected by the height of 5 and 6 mm prostheses, but were strongly affected by the 7-mm prosthesis. An appropriate height of the Prestige LP prosthesis can preserve normal ROM, adjacent intradiscal pressure, and facet joint force. Prostheses with a height of ≥2 mm than normal can lead to marked changes in the cervical biomechanics and bone-implant interface stress. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Comparison of mechanical and biological prostheses when used to replace heart valves in children and adolescents with rheumatic fever.

    PubMed

    Travancas, Paulo R; Dorigo, Ana H; Simões, Luiz C; Fonseca, Sandra C; Bloch, Kátia V; Herdy, Gesmar V

    2009-04-01

    To assess the outcomes in children and adolescents with rheumatic fever of the implantation of mechanical as opposed to biological heart valves. We assessed 73 patients with rheumatic heart disease under the age of 18 years, who underwent replacement of heart valves between January, 1996, and December, 2005, at the National Institute of Cardiology in Rio de Janeiro, Brazil. Of the group, 71 patients survived, and were divided into a group of 52 receiving mechanical prostheses, and 19 with biological prostheses. We compared endpoints between the groups in terms of mortality, reoperation, haemorrhage, and stroke. Survival curves were estimated using the Kaplan-Meier method and were compared by the Mantel (log-rank) test. Overall mortality was 8.2%. In those receiving mechanical prostheses, 2 (3.8%) patients died, 5 (9.6%) underwent reoperation, 2 (3.8%) suffered severe haemorrhage, and 3 (5.8%) had strokes. In those receiving biological valves, 2 (10.5%) patients died, and 4 (21%) underwent reoperation. After 2, 4, and 8 years, overall survival was 96%, 93% and 86%, respectively, with a borderline difference between the groups (p = 0.06). The probabilities of remaining free from reoperation (p = 0.13), and from combined endpoints, showed no statistically significant difference between the groups (p = 0.28). Patients with mechanical prostheses had lower mortality and required fewer reoperations, but when all combined endpoints were considered, the groups did not differ. The biological prosthesis proved to be a good option for cardiac surgery in children and adolescents with difficulties or risks of anticoagulation.

  12. In vitro assessment of the contact mechanics of reverse-engineered distal humeral hemiarthroplasty prostheses.

    PubMed

    Willing, Ryan; Lapner, Michael; King, Graham J W; Johnson, James A

    2014-11-01

    Distal humeral hemiarthroplasty alters cartilage contact mechanics, which may predispose to osteoarthritis. Current prostheses do not replicate the native anatomy, and therefore contribute to these changes. We hypothesized that prostheses reverse-engineered from the native bone shape would provide similar contact patterns as the native articulation. Reverse-engineered hemiarthroplasty prostheses were manufactured for five cadaveric elbows based on CT images of the distal humerus. Passive flexion trials with constant muscle forces were performed with the native articulation intact while bone motions were recorded using a motion tracking system. Motion trials were then repeated after the distal humerus was replaced with a corresponding reverse-engineered prosthesis. Contact areas and patterns were reconstructed using computer models created from CT scan images combined with the motion tracker data. The total contact areas, as well as the contact area within smaller sub-regions of the ulna and radius, were analyzed for changes resulting from hemiarthroplasty using repeated-measures ANOVAs. Contact area at the ulna and radius decreased on average 42% (SD 19%, P=.008) and 41% (SD 42%, P=.096), respectively. Contact area decreases were not uniform throughout the different sub-regions, suggesting that contact patterns were also altered. Reverse-engineered prostheses did not reproduce the same contact pattern as the native joints, possibly because the thickness of the distal humerus cartilage layer was neglected when generating the prosthesis shapes or as a consequence of the increased stiffness of the metallic implants. Alternative design strategies and materials for hemiarthroplasty should be considered in future work. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. PERSPECTIVE: Is acuity enough? Other considerations in clinical investigations of visual prostheses

    NASA Astrophysics Data System (ADS)

    Lepri, Bernard P.

    2009-06-01

    Visual impairing eye diseases are the major frontier facing ophthalmic research today in light of our rapidly aging population. The visual skills necessary for improving the quality of daily function and life are inextricably linked to these impairing diseases. Both research and reimbursement programs are emphasizing outcome-based results. Is improvement in visual acuity alone enough to improve the function and quality of life of visually impaired persons? This perspective summarizes the types of effectiveness endpoints for clinical investigations of visual prostheses that go beyond visual acuity. The clinical investigation of visual prostheses should include visual function, functional vision and quality of life measures. Specifically, they encompass contrast sensitivity, orientation and mobility, activities of daily living and quality of life assessments. The perspective focuses on the design of clinical trials for visual prostheses and the methods of determining effectiveness above and beyond visual acuity that will yield outcomes that are measured by improved function in the visual world and quality of life. The visually impaired population is the primary consideration in this presentation with particular emphases on retinitis pigmentosa and age-related macular degeneration. Clinical trials for visual prostheses cannot be isolated from the need for medical rehabilitation in order to obtain measurements of effectiveness that produce outcomes/evidence-based success. This approach will facilitate improvement in daily function and quality of life of patients with diseases that cause chronic vision impairment. The views and opinions are those of the author and do not necessarily reflect those of the US Food and Drug Administration, the US Department of Health and Human Services or the Public Health Service.

  14. Effect of prosthesis endplate lordosis angles on L5-S1 kinematics after disc arthroplasty.

    PubMed

    Tsitsopoulos, Parmenion P; Wojewnik, Bartosz; Voronov, Leonard I; Havey, Robert M; Renner, Susan M; Zelenakova, Julia; McIntosh, Braden; Carandang, Gerard; Abjornson, Celeste; Patwardhan, Avinash G

    2012-06-01

    We hypothesized that L5-S1 kinematics will not be affected by the lordosis distribution between the prosthesis endplates. Twelve cadaveric lumbosacral spines (51.3 ± 9.8 years) were implanted with 6° or 11° prostheses (ProDisc-L) with four combinations of superior/inferior lordosis (6°/0°, 3°/3°, 11°/0°, 3°/8°). Specimens were tested intact and after prostheses implantation with different lordosis distributions. Center of rotation (COR) and range of motion (ROM) were quantified. Six-degree lordosis prostheses (n = 7) showed no difference in flexion-extension ROM, regardless of design (6°/0° or 3°/3°) (p > 0.05). In lateral bending (LB), both designs reduced ROM (p < 0.05). In axial rotation, only the 3°/3° design reduced ROM (p < 0.05). Eleven-degree lordosis prostheses (n = 5) showed no difference in flexion-extension ROM for either design (p > 0.05). LB ROM decreased with distributed lordosis prostheses (3°/8°) (p < 0.05). Overall, L5-S1 range of motion was not markedly influenced by lordosis distribution among the two prosthesis endplates. The ProDisc-L prosthesis design where all lordosis is concentrated in the superior endplate yielded COR locations that were anterior and caudal to intact controls. The prosthesis with lordosis distributed between the two endplates yielded a COR that tended to be closer to intact. Further clinical and biomechanical studies are needed to assess the long-term impact of lordosis angle distribution on the fate of the facet joints.

  15. Success rate in implant-supported overdenture and implant-supported fixed denture in cleft lip and palate patients

    PubMed Central

    Zanolla, Jaine; Amado, Flávio Monteiro; da Silva, Willian Saranholi; Ayub, Bruno; de Almeida, Ana Lúcia Pompéia Fraga; Soares, Simone

    2016-01-01

    Background: The prosthetic treatment in cleft patients is challenging. Based on this, the aim of this study was to evaluate the longevity of prosthetic rehabilitation treatment with implant-supported overdenture (IOD) and implant-supported fixed denture (IFD) in cleft lip and palate patients in a period of 22 years. Materials and Methods: The medical records of 72 patients were analyzed (29 males and 43 females), and the survival rate of the implants was evaluated. Moreover, the prostheses’ time of use and the reason for the changing of these were also evaluated. Results: Four-hundred-seventeen implants were installed, and 370 implants survive today. The mean survival time of the implants was 7.6 years. Regarding the 97 prostheses made, the time of average use was 3.28 for the IFDs and 3.92 for IODs. The reasons for the replacements of the prostheses were mainly: fracture of the acrylic base (29.6%) and loss of vertical dimension of occlusion (VDO) (18.5%) in the IFDs. Moreover, in IODs, these were accounted for the loss of VDO due to teeth damage (17.2%) and implant loss (14.6%). Conclusions: The maintenance of the prostheses was challenging because the patients had difficulties returning for periodic control, but this fact did not result in the decrease of the success rate of the implants. The longevity of implants and prostheses was satisfactory; however, the prostheses showed repetitions mainly due to the wear of the teeth, with decreased vertical dimension and fracture of acrylic base. PMID:28299262

  16. Tracheostomy cannulas and voice prosthesis.

    PubMed

    Kramp, Burkhard; Dommerich, Steffen

    2009-01-01

    Cannulas and voice prostheses are mechanical aids for patients who had to undergo tracheotomy or laryngectomy for different reasons. For better understanding of the function of those artificial devices, first the indications and particularities of the previous surgical intervention are described in the context of this review. Despite the established procedure of percutaneous dilatation tracheotomy e.g. in intensive care units, the application of epithelised tracheostomas has its own position, especially when airway obstruction is persistent (e.g. caused by traumata, inflammations, or tumors) and a longer artificial ventilation or special care of the patient are required. In order to keep the airways open after tracheotomy, tracheostomy cannulas of different materials with different functions are available. For each patient the most appropriate type of cannula must be found. Voice prostheses are meanwhile the device of choice for rapid and efficient voice rehabilitation after laryngectomy. Individual sizes and materials allow adaptation of the voice prostheses to the individual anatomical situation of the patients. The combined application of voice prostheses with HME (Head and Moisture Exchanger) allows a good vocal as well as pulmonary rehabilitation. Precondition for efficient voice prosthesis is the observation of certain surgical principles during laryngectomy. The duration of the prosthesis mainly depends on material properties and biofilms, mostly consisting of funguses and bacteries. The quality of voice with valve prosthesis is clearly superior to esophagus prosthesis or electro-laryngeal voice. Whenever possible, tracheostoma valves for free-hand speech should be applied. Physicians taking care of patients with speech prostheses after laryngectomy should know exactly what to do in case the device fails or gets lost.

  17. Composite Materials for Maxillofacial Prostheses.

    DTIC Science & Technology

    1982-11-01

    1(AXILLOFACIAL PROSTHESES; PROSTHETIC MATERIALS: MICROCAPSULES : SOFT FILLERS; ELASTOMER COMPOSITES *ASTRAC7 lCofIflU Ir F*vsda Side It neceOaeen anud...composite systems are elastomeric-shelled, liquid-filled microcapsules . Experiments continued on the interfacial polymerization process, with spherical...sealed, capsules achieved. The diamine bath has been E] improved and an automatic system has been developed for producing the microcapsules . The one

  18. Visual Prostheses: The Enabling Technology to Give Sight to the Blind

    PubMed Central

    Maghami, Mohammad Hossein; Sodagar, Amir Masoud; Lashay, Alireza; Riazi-Esfahani, Hamid; Riazi-Esfahani, Mohammad

    2014-01-01

    Millions of patients are either slowly losing their vision or are already blind due to retinal degenerative diseases such as retinitis pigmentosa (RP) and age-related macular degeneration (AMD) or because of accidents or injuries. Employment of artificial means to treat extreme vision impairment has come closer to reality during the past few decades. Currently, many research groups work towards effective solutions to restore a rudimentary sense of vision to the blind. Aside from the efforts being put on replacing damaged parts of the retina by engineered living tissues or microfabricated photoreceptor arrays, implantable electronic microsystems, referred to as visual prostheses, are also sought as promising solutions to restore vision. From a functional point of view, visual prostheses receive image information from the outside world and deliver them to the natural visual system, enabling the subject to receive a meaningful perception of the image. This paper provides an overview of technical design aspects and clinical test results of visual prostheses, highlights past and recent progress in realizing chronic high-resolution visual implants as well as some technical challenges confronted when trying to enhance the functional quality of such devices. PMID:25709777

  19. Accelerated treatment protocols: full arch treatment with interim and definitive prostheses.

    PubMed

    Drago, Carl

    2012-01-01

    With the advent of titanium, root form implants and osseointegration, dental treatment has undergone a metamorphosis in recent years. These new techniques enable dentists to provide anchorage for various kinds of prostheses that improve masticatory function, esthetics, and comfort for patients. Implant treatment protocols have been improved relative to implant macro- and micro-geometries, surgical and prosthetic components, and treatment times. Over the past 20 years, immediate occlusal function (also known as loading) has been established as a predictable treatment modality, provided certain specific criteria are met. In many cases, edentulous patients, crippled by the loss of their teeth, can undergo outpatient surgical and prosthetic procedures and return to a masticatory function that is near normal--sometimes after only one day of surgical and prosthetic treatment. This treatment option is also available for patients with advanced, generalized periodontal disease. Computer-assisted design/Computer-assisted manufacturing (CAD/CAM) has transformed how dental prostheses are made, offering improved accuracy, longevity, and biocompatibility; along with reduced labor costs and fewer complications than casting technologies. This article reviews the principles associated with immediate occlusal loading and illustrates one specific accelerated prosthodontic treatment protocol used to treat edentulous and partially edentulous patients with interim and definitive prostheses.

  20. Frequency of technical complications in fixed implant prosthesis: the effect of prosthesis screw emergence correction by CAD-CAM.

    PubMed

    Anitua, Eduardo; Flores, Carlos; Piñas, Laura; Alkhraisat, Mohammad

    2018-06-05

    CAD-CAM technology permits the angular correction of screw emergence into the prosthesis, however there is lack of controlled clinical studies that assess the frequency of technical complications in angled screw channel restorations. This controlled clinical study was designed to assess technical incidences in angled screw channel restorations. Patients having implant prosthesis placed between November, 2014 and December, 2015 were screened. The patients were selected if they received prosthesis with up to 30º correction of the prosthesis screw emergence and had at least one non-angulated prosthesis (screw-retained). All the prostheses were located completely/partially in the posterior region. The frequency of technical complications was the principal variable. A total of 52 patients with a mean age of 62 ± 10 years participated with a total 110 prostheses (55 in the test group and 55 in the control group). A total of 11 technical complications occurred (7 in the test group and 4 in the control group). These differences were not statistically significant. All the prostheses in both groups survived the follow-up. The correction of the screw emergence into the prosthesis has not increased the risk of technical complications in CAD-CAM implant prostheses.

  1. PARTICIPATORY DESIGN OF PEDIATRIC UPPER LIMB PROSTHESES: QUALITATIVE METHODS AND PROTOTYPING.

    PubMed

    Sims, Tara; Cranny, Andy; Metcalf, Cheryl; Chappell, Paul; Donovan-Hall, Maggie

    2017-01-01

    The study aims to develop an understanding of the views of children and adolescents, parents, and professionals on upper limb prosthetic devices to develop and improve device design. Previous research has found that children are dissatisfied with prostheses but has relied heavily on parent proxy reports and quantitative measures (such as questionnaires) to explore their views. Thirty-four participants (eight children aged 8-15 years with upper limb difference, nine parents, eight prosthetists, and nine occupational therapists) contributed to the development of new devices through the BRIDGE methodology of participatory design, using focus groups and interviews. The study identified areas for improving prostheses from the perspective of children and adolescents, developed prototypes based on these and gained feedback on the prototypes from the children and other stakeholders (parents and professionals) of paediatric upper limb prostheses. Future device development needs to focus on ease of use, versatility, appearance, and safety. This study has demonstrated that children and adolescents can and should be involved as equal partners in the development of daily living equipment and that rapid prototyping (three-dimensional printing or additive manufacturing), used within a participatory design framework, can be a useful tool for facilitating this.

  2. Improvement on upper limb body-powered prostheses (1921-2016): A systematic review.

    PubMed

    Hashim, Nur Afiqah; Abd Razak, Nasrul Anuar; Abu Osman, Noor Azuan; Gholizadeh, Hossein

    2018-01-01

    Body-powered prostheses are known for their advantages of cost, reliability, training period, maintenance, and proprioceptive feedback. This study primarily aims to analyze the work related to the improvement of upper limb body-powered prostheses prior to 2016. A systematic review conducted via the search of the Web of Science electronic database, Google Scholar, and Google Patents identified 155 papers from 1921 to 2016. Sackett's initial rules of evidence were used to determine the levels of evidence, and only papers categorized in the design and development category and patents were analyzed. A total of 40 papers in the sixth level of "Design and Development" of an upper limb body-powered prosthesis were found. Approximately 81% were categorized under mechanical alteration. Most papers were patent-type documents (48%), with the Journal of Rehabilitation Research and Development publishing most of the articles related to the design and development of body-powered prostheses. Papers in the scope of the study were published once every 3 years in almost a century, proving that only a few studies were conducted to improve body-powered arms compared with myoelectric technology. Further research should be carried out mainly in areas that have received less attention.

  3. Safety of MRI with metallic middle ear implants.

    PubMed

    Tohme, Souheil M; Karkas, Alexandre A; Romanos, Bassam H

    2003-01-01

    Investigation of the effects of magnetic resonance fields on commonly used metallic middle ear implants. Nine middle ear prostheses (seven containing stainless steel and two made of pure gold used as control) were tested in vitro and one stainless steel stapedectomy prosthesis was tested on a cadaveric temporal bone. Each metallic prosthesis was placed in an empty Petri dish and introduced into a 1.5-tesla (T) magnetic resonance imaging (MRI) unit. Most of the prostheses were then placed in a water-filled Petri dish and reintroduced into the MRI unit. Eventual in vitro displacement was assessed visually by two means. In situ testing was done by implanting a piston in a cadaveric temporal bone and performing MR sequences ; any possible displacement was then assessed by CT scan and under microscopic vision. None of the prostheses was displaced in the empty Petri dish. However, while in the water-filled Petri dish, three of these moved with the flux. The implanted piston in the temporal bone did not move. The displacement of three of the prostheses in water is not relevant in real clinical situations. MRI can thus be considered safe in usual clinical settings, as far as our studied implants are concerned.

  4. Safety of magnetic resonance imaging of stapes prostheses.

    PubMed

    Syms, Mark James

    2005-03-01

    Assess the safety of performing magnetic resonance imaging (MRI) on patients with stapes prostheses. Survey and animal model. A survey regarding implant usage, MRI procedures, and adverse outcomes after MRI in patients previously undergoing stapes procedures. Guinea pigs implanted with ferromagnetic 17 to 4 stainless steel, 316L nonferromagnetic stainless steel, titanium, and fluoroplastic stapes prostheses underwent a MRI in a 4.7 Tesla MR system. : Three adverse outcomes were reported on the clinical survey. One adverse event occurred during an MRI performed on a recalled ferromagnetic prosthesis. The other two adverse events were probably not secondary to MRI exposure. No damage or inflammation was observed in the region of the oval window or vestibule of implanted guinea pigs exposed to a 4.7 Tesla MR system. The combination of prior studies, the clinical survey, and the absence of histopathologic evidence of damage in the guinea pigs is compelling evidence that MRI for patients with stapes prostheses is safe. Implanting physicians should feel comfortable clearing a patient for a MRI in a 1.5 Tesla or 3.0 Tesla MRI. It is imperative for the physician to qualify the field strength when clearing a patient to undergo a MRI.

  5. [Polish vascular prosthesis sealed by albumin].

    PubMed

    Raczyński, K; Dyczka, A; Gawlikowska, Z

    1992-01-01

    TRICOMED, Medical Articles has been conducting its research on textile vascular prostheses for over 35 years. In the seventies, a collagen coated graft was designed and fabricated which, however, after having been positively evaluated ceased to be used by clinics. In the eighties, double velour DALLONR prostheses was introduced which are now marketed by our company. The DALLONR graft has a low mass, developed surface area and moderate porosity. In the eighties, foreign manufacturers launched various types of coated grafts. Responding to that popular market trend we have resumed our early research on the preclotted prostheses and started studies on the use of albumin and chitosan as coating agents. The grafts impregnated with albumin have achieved satisfactory results of biological and experimental testing. These results are confirmed by current clinical examination.

  6. Spring Ankle with Regenerative Kinetics to Build a New Generation of Transtibial Prostheses

    DTIC Science & Technology

    2008-07-31

    form factor that is portable to the wearer. The objective is to build a transtibial prosthesis that will support a Military amputee’s return to...active duty. 15. SUBJECT TERMS Transtibial Prosthesis , regenerative, spring, wearable robot 16. SECURITY CLASSIFICATION OF: 17. LIMITATION...Regenerative Kinetics” to build a new generation of transtibial prostheses Keywords: Transtibial Prosthesis , regenerative, spring, wearable robot

  7. Automated generation of IMRT treatment plans for prostate cancer patients with metal hip prostheses: Comparison of different planning strategies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Voet, Peter W. J.; Dirkx, Maarten L. P.; Breedveld, Sebastiaan

    2013-07-15

    Purpose: To compare IMRT planning strategies for prostate cancer patients with metal hip prostheses.Methods: All plans were generated fully automatically (i.e., no human trial-and-error interactions) using iCycle, the authors' in-house developed algorithm for multicriterial selection of beam angles and optimization of fluence profiles, allowing objective comparison of planning strategies. For 18 prostate cancer patients (eight with bilateral hip prostheses, ten with a right-sided unilateral prosthesis), two planning strategies were evaluated: (i) full exclusion of beams containing beamlets that would deliver dose to the target after passing a prosthesis (IMRT{sub remove}) and (ii) exclusion of those beamlets only (IMRT{sub cut}). Plansmore » with optimized coplanar and noncoplanar beam arrangements were generated. Differences in PTV coverage and sparing of organs at risk (OARs) were quantified. The impact of beam number on plan quality was evaluated.Results: Especially for patients with bilateral hip prostheses, IMRT{sub cut} significantly improved rectum and bladder sparing compared to IMRT{sub remove}. For 9-beam coplanar plans, rectum V{sub 60Gy} reduced by 17.5%{+-} 15.0% (maximum 37.4%, p= 0.036) and rectum D{sub mean} by 9.4%{+-} 7.8% (maximum 19.8%, p= 0.036). Further improvements in OAR sparing were achievable by using noncoplanar beam setups, reducing rectum V{sub 60Gy} by another 4.6%{+-} 4.9% (p= 0.012) for noncoplanar 9-beam IMRT{sub cut} plans. Large reductions in rectum dose delivery were also observed when increasing the number of beam directions in the plans. For bilateral implants, the rectum V{sub 60Gy} was 37.3%{+-} 12.1% for coplanar 7-beam plans and reduced on average by 13.5% (maximum 30.1%, p= 0.012) for 15 directions.Conclusions: iCycle was able to automatically generate high quality plans for prostate cancer patients with prostheses. Excluding only beamlets that passed through the prostheses (IMRT{sub cut} strategy) significantly improved OAR sparing. Noncoplanar beam arrangements and, to a larger extent, increasing the number of treatment beams further improved plan quality.« less

  8. Influence of material coupling and assembly condition on the magnitude of micromotion at the stem-neck interface of a modular hip endoprosthesis.

    PubMed

    Jauch, S Y; Huber, G; Hoenig, E; Baxmann, M; Grupp, T M; Morlock, M M

    2011-06-03

    Hip prostheses with a modular neck exhibit, compared to monobloc prostheses, an additional interface which bears the risk of fretting as well as corrosion. Failures at the neck adapter of modular prostheses have been observed for a number of different designs. It has been speculated that micromotions at the stem-neck interface were responsible for these implant failures. The purpose of this study was to investigate the influence of material combinations and assembly conditions on the magnitude of micromotions at the stem-neck interface during cyclic loading. Modular (n = 24) and monobloc (n = 3) hip prostheses of a similar design (Metha, Aesculap AG, Tuttlingen, Germany) were subjected to mechanical testing according to ISO 7206-4 (F(min) = 230N, F(max) = 2300N, f = 1Hz, n = 10,000 cycles). The neck adapters (Ti-6Al-4V or Co-Cr29-Mo alloy) were assembled with a clean or contaminated interface. The micromotion between stem and neck adapter was calculated at five reference points based on the measurements of the three eddy current sensors. The largest micromotions were observed at the lateral edge of the stem-neck taper connection, which is in accordance with the crack location of clinically failed prostheses. Titanium neck adapters showed significantly larger micromotions than cobalt-chromium neck adapters (p = 0.005). Contaminated interfaces also exhibited significantly larger micromotions (p < 0.001). Since excessive micromotions at the stem-neck interface might be involved in the process of implant failure, special care should be taken to clean the interface prior to assembly and titanium neck adapters with titanium stems should generally be used with caution. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. Effect of alignment changes on socket reaction moments while walking in transtibial prostheses with energy storage and return feet.

    PubMed

    Kobayashi, Toshiki; Arabian, Adam K; Orendurff, Michael S; Rosenbaum-Chou, Teri G; Boone, David A

    2014-01-01

    Energy storage and return feet are designed for active amputees. However, little is known about the socket reaction moments in transtibial prostheses with energy storage and return feet. The aim of this study was to investigate the effect of alignment changes on the socket reaction moments during gait while using the energy storage and return feet. A Smart Pyramid™ was used to measure the socket reaction moments in 10 subjects with transtibial prostheses while walking under 25 alignment conditions, including a nominal alignment (as defined by conventional clinical methods), as well as angle malalignments of 2°, 4° and 6° (flexion, extension, abduction, and adduction) and translation malalignments of 5mm, 10mm and 15mm (anterior, posterior, lateral, and medial) referenced from the nominal alignment. The socket reaction moments of the nominal alignment were compared with each malalignment. Both coronal and sagittal alignment changes demonstrated systematic effects on the socket reaction moments. In the sagittal plane, angle and translation alignment changes demonstrated significant differences (P<0.05) in the minimum moment, the moment at 45% of stance and the maximum moment for some comparisons. In the coronal plane, angle and translation alignment changes demonstrated significant differences (P<0.05) in the moment at 30% and 75% of stance for all comparisons. The alignment may have systematic effects on the socket reaction moments in transtibial prostheses with energy storage and return feet. The socket reaction moments could potentially be a useful biomechanical parameter to evaluate the alignment of the transtibial prostheses. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. [Surgical silicone prostheses in the treatment of biliary tract cancers: long prostheses or short prostheses? Results apropos of 500 cases].

    PubMed

    Kron, B

    1992-10-01

    The interest of surgical prostheses in the palliative treatment of biliary tract cancer is well established, on the basis of their good tolerance, the more than 15 year follow up experience and the number of patients operated upon. After exeresis, they allow re-establishment of continuity, either by use of a prosthesis in Y when the right and let ducts can be dissected, or by using two prostheses, a multiperforated long prosthesis reimplanted in the duodenum and a short prosthesis reimplanted in the common bile duct without attaining the sphincter of Oddi. Of the 1000 cases treated, 500 were the object of a statistical analysis, 46 being operated upon by the author, in 60% of cases for biliary tract cancer, either primary or as an extension from the gallbladder. One-third of the patients had advanced lesions and a short survival of less than 3 months. Two-thirds a median survival of 9 months. In 10%, a radical exeresis was performed with survival of more than one year without recurrence of jaundice. Failure of treatment with persistence of jaundice was due to advanced disease for which surgery is unsatisfactory. Essential complications were premature bile leaks (5%) without serious consequences if sufficient drainage was maintained, since it stopped spontaneously, and angiocholitis (6%), the result of territory exclusion or reflux. Recurrence of jaundice was related to extension of the neoplasm to the secondary bile ducts, and to hepatic metastases. Obstruction of the prosthesis before two months was rare (6%) and was preceded by angiocholitis. In the absence of recurrence of the cancer the prosthesis can be replaced surgically without difficulty.

  11. Implants for elderly patients.

    PubMed

    Schimmel, Martin; Müller, Frauke; Suter, Valérie; Buser, Daniel

    2017-02-01

    In the developed world, the large birth cohorts of the so-called baby boomer generation have arrived in medical and dental practices. Often, elderly patients are 'young-old' baby boomers in whom partial edentulism is the predominant indication for implant therapy. However, the generation 85+ years of age represents a new challenge for the dental profession, as their lives are frequently dominated by dependency, multimorbidity and frailty. In geriatric implant dentistry, treatment planning is highly individualized, as interindividual differences become more pronounced with age. Nevertheless, there are four typical indications for implant therapy: (i) avoidance of removable partial prostheses; (ii) preservation of existing removable partial prostheses; (iii) stabilization of Kennedy Class I removable partial prostheses; and (iv) stabilization of complete prostheses. From a surgical point of view, two very important aspects must be considered when planning implant surgery in elderly patients: first, the consistent strive to minimize morbidity; and, second, the fact that coexisting medical risk factors are significantly more common in elderly patients. Modern three-dimensional cone beam computed tomography imaging is often indicated in order to plan minimally invasive implant surgery. Computer-assisted implant surgery might allow flapless implant surgery, which offers a low level of postoperative morbidity and a minimal risk of postsurgical bleeding. Short and reduced-diameter implants are now utilized much more often than a decade ago. Two-stage surgical procedures should be avoided in elderly patients. Implant restorations for elderly patients should be designed so that they can be modified to become low-maintenance prostheses, or even be removed, as a strategy to facilitate oral hygiene and comfort in the final stage of life. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Noninvasive radioisotopic technique for detection of platelet deposition in mitral valve prostheses and quantitation of visceral microembolism in dogs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dewanjee, M.K.; Fuster, V.; Rao, S.A.

    1983-05-01

    A noninvasive technique has been developed in the dog model for imaging, with a gamma camera, the platelet deposition on Bjoerk-Shiley mitral valve prostheses early postoperatively. At 25 hours after implantation of the prosthesis and 24 hours after intravenous administration of 400 to 500 microCi of platelets labeled with indium-111, the platelet deposition in the sewing ring and perivalvular cardiac tissue can be clearly delineated in a scintiphotograph. An in vitro technique was also developed for quantitation of visceral microemboli in brain, lungs, kidneys, and other tissues. Biodistribution of the labeled platelets was quantitated, and the tissue/blood radioactivity ratio wasmore » determined in 22 dogs in four groups: unoperated normal dogs, sham-operated dogs, prosthesis-implanted dogs, and prosthesis-implanted dogs treated with dipyridamole before and aspirin and dipyridamole immediately after operation. Fifteen to 20% of total platelets were consumed as a consequence of the surgical procedure. On quantitation, we found that platelet deposition on the components of the prostheses was significantly reduced in prosthesis-implanted animals treated with dipyridamole and aspirin when compared with prosthesis-implanted, untreated dogs. All prosthesis-implanted animals considered together had a twofold to fourfold increase in tissue/blood radioactivity ratio in comparison with unoperated and sham-operated animals, an indication that the viscera work as filters and trap platelet microemboli that are presumably produced in the region of the mitral valve prostheses. In the dog model, indium-111-labeled platelets thus provide a sensitive marker for noninvasive imaging of platelet deposition on mechanical mitral valve prostheses, in vitro evaluation of platelet microembolism in viscera, in vitro quantitation of surgical consumption of platelets, and evaluation of platelet-inhibitor drugs.« less

  13. Food selection and perceptions of chewing ability following provision of implant and conventional prostheses in complete denture wearers.

    PubMed

    Allen, Finbarr; McMillan, Anne

    2002-06-01

    The loss of natural teeth compromises chewing efficiency, and edentulous patients often have a diet that is deficient in fibre and vitamins. Prostheses that are retained on implants offer the possibility of overcoming some of the limitations of conventional dentures in terms of chewing efficiency. The aim of this study was to test the hypothesis that improvement in satisfaction with oral prostheses would result in improved food selection in edentulous patients. This prospective study involved three groups, namely (i) subjects who requested and received implants to stabilise a complete fixed or removable prosthesis (IG, n = 26), (ii) edentulous subjects who requested implant prostheses, but received conventional dentures (CDG1, n = 22), and (iii) edentulous subjects who requested and received conventional dentures (CDG2, n = 35). Data were collected using validated questionnaires pre- and postoperatively. Prior to treatment, all subjects were asked whether they ate a variety of hard and soft foods, to indicate the degree of difficulty they experienced when chewing these foods, and to rate their satisfaction with various aspects of their maxillary and mandibular complete dentures. Following the completion of treatment, subjects completed the questionnaires again. Pre- and postoperative data were compared. Subjects who received implant prostheses reported significant improvement in chewing hard and soft foods. CDG2 subjects also reported improvement, but CDG1 subjects reported no change or even deterioration following treatment. Despite reported improvement in satisfaction with comfort and ability to chew food, 30-50% of IG and CDG2 subjects still avoided eating foods such as carrot and apple. This suggests that, in the absence of tailored dietary advice, apparently successful prosthetic rehabilitation does not necessarily result in a satisfactory diet.

  14. Functional changes through the usage of 3D-printed transitional prostheses in children.

    PubMed

    Zuniga, Jorge M; Peck, Jean L; Srivastava, Rakesh; Pierce, James E; Dudley, Drew R; Than, Nicholas A; Stergiou, Nicholas

    2017-11-08

    There is limited knowledge on the use of 3 D-printed transitional prostheses, as they relate to changes in function and strength. Therefore, the purpose of this study was to identify functional and strength changes after usage of 3 D-printed transitional prostheses for multiple weeks for children with upper-limb differences. Gross manual dexterity was assessed using the Box and Block Test and wrist strength was measured using a dynamometer. This testing was conducted before and after a period of 24 ± 2.61 weeks of using a 3 D-printed transitional prosthesis. The 11 children (five girls and six boys; 3-15 years of age) who participated in the study, were fitted with a 3 D-printed transitional partial hand (n = 9) or an arm (n = 2) prosthesis. Separate two-way repeated measures ANOVAs were performed to analyze function and strength data. There was a significant hand by time interaction for function, but not for strength. Conclusion and relevance to the study of disability and rehabilitation: The increase in manual gross dexterity suggests that the Cyborg Beast 2 3 D-printed prosthesis can be used as a transitional device to improve function in children with traumatic or congenital upper-limb differences. Implications for Rehabilitation Children's prosthetic needs are complex due to their small size, rapid growth, and psychosocial development. Advancements in computer-aided design and additive manufacturing offer the possibility of designing and printing transitional prostheses at a very low cost, but there is limited knowledge on the function of this type of devices. The use of 3D printed transitional prostheses may improve manual gross dexterity in children after several weeks of using it.

  15. Effect of beverages and mouthwashes on the hardness of polymers used in intraoral prostheses.

    PubMed

    Goiato, Marcelo Coelho; Dos Santos, Daniela Micheline; Andreotti, Agda Marobo; Nobrega, Adhara Smith; Moreno, Amalia; Haddad, Marcela Filié; Pesqueira, Aldiéris Alves

    2014-10-01

    The mechanical properties of acrylic resins used in intraoral prostheses may be altered by frequent exposure to liquids such as beverages and mouthwashes. This study aimed to evaluate the effect of thermocycling and liquid immersion on the hardness of four brands of acrylic resins commonly used in removable prostheses (Onda Cryl, QC-20, Clássico, Lucitone). For each brand of resin, seven specimens were immersed in each of six solutions (coffee, cola, red wine, Plax-Colgate, Listerine [LI], Oral B), and seven more were placed in artificial saliva (control). The hardness was tested using a microhardness tester before and after 5000 thermocycles and after 1, 3, 24, 48, and 96 hours of immersion. The results were analyzed using three-way repeated-measures ANOVA and Tukey's test (p < 0.05). The hardness of the resins decreased following thermocycling and immersion in the solutions. Specimens immersed in cola and wine exhibited significant decreases in hardness after immersion for 96 hours, although the greatest significant decrease in hardness occurred in specimens immersed in LI. However, according to American Dental Association specification 12, the Knoop hardness of acrylic resins for intraoral prostheses should not be below 15. Thus, the median values of superficial hardness observed in most of the acrylic resins in this study are considered clinically acceptable. The microhardness of polymers used for intraoral prostheses decreases following thermocycling. Among specimens immersed in beverages, those immersed in cola or wine experienced the greatest decrease in microhardness. Immersion of acrylic resins in LI significantly decreased the microhardness in relation to the initial value. Among the resins assessed, QC-20 exhibited the lowest initial hardness. © 2014 by the American College of Prosthodontists.

  16. Influence of oral health condition on swallowing and oral intake level for patients affected by chronic stroke.

    PubMed

    Mituuti, Cláudia T; Bianco, Vinicius C; Bentim, Cláudia G; de Andrade, Eduardo C; Rubo, José H; Berretin-Felix, Giédre

    2015-01-01

    According to the literature, the occurrence of dysphagia is high in cases of stroke, and its severity can be enhanced by loss of teeth and the use of poorly fitting prostheses. To verify that the status of oral health influences the level of oral intake and the degree of swallowing dysfunction in elderly patients with stroke in chronic phase. Thirty elderly individuals affected by stroke in chronic phase participated. All subjects underwent assessment of their oral condition, with classification from the Functional Oral Intake Scale (FOIS) and nasoendoscopic swallowing assessment to classify the degree of dysphagia. The statistical analysis examined a heterogeneous group (HG, n=30) and two groups designated by the affected body part, right (RHG, n=8) and left (LHG, n=11), excluding totally dentate or edentulous individuals without rehabilitation with more than one episode of stroke. There was a negative correlation between the need for replacement prostheses and the FOIS scale for the HG (P=0.02) and RHG (P=0.01). Differences in FOIS between types of prostheses of the upper dental arch in the LHG (P=0.01) and lower dental arch in the RHG (P=0.04). A negative correlation was found between the number of teeth present and the degree of dysfunction in swallowing liquid in the LHG (P=0.05). There were differences in the performance in swallowing solids between individuals without prosthesis and those with partial prosthesis in the inferior dental arch (P=0.04) for the HG. The need for replacement prostheses, type of prostheses, and the number of teeth of elderly patients poststroke in chronic phase showed an association with the level of oral intake and the degree of oropharyngeal dysphagia.

  17. An integrated CAD/CAM/robotic milling method for custom cementless femoral prostheses.

    PubMed

    Wen-ming, Xi; Ai-min, Wang; Qi, Wu; Chang-hua, Liu; Jian-fei, Zhu; Fang-fang, Xia

    2015-09-01

    Aseptic loosening is the primary cause of cementless femoral prosthesis failure and is related to the primary stability of the cementless femoral prosthesis in the femoral cavity. The primary stability affects both the osseointegration and the long-term stability of cementless femoral prostheses. A custom cementless femoral prosthesis can improve the fit and fill of the prosthesis in the femoral cavity and decrease the micromotion of the proximal prosthesis such that the primary stability of the custom prosthesis can be improved, and osseointegration of the proximal prosthesis is achieved. These results will help to achieve long-term stability in total hip arthroplasty (THA). In this paper, we introduce an integrated CAD/CAM/robotic method of milling custom cementless femoral prostheses. The 3D reconstruction model uses femoral CT images and 3D design software to design a CAD model of the custom prosthesis. After the transformation matrices between two units of the robotic system are calibrated, consistency between the CAM software and the robotic system can be achieved, and errors in the robotic milling can be limited. According to the CAD model of the custom prosthesis, the positions of the robotic tool points are produced by the CAM software of the CNC machine. The normal vector of the three adjacent robotic tool point positions determines the pose of the robotic tool point. In conclusion, the fit rate of custom pig femur stems in the femoral cavities was 90.84%. After custom femoral prostheses were inserted into the femoral cavities, the maximum gaps between the prostheses and the cavities measured less than 1 mm at the diaphysis and 1.3 mm at the metaphysis. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  18. Clinical experiences with laser-welded titanium frameworks supported by implants in the edentulous mandible: a 5-year follow-up study.

    PubMed

    Ortorp, A; Linden, B; Jemt, T

    1999-01-01

    The purpose of this study was to report the 5-year clinical performance of implant-supported prostheses with laser-welded titanium frameworks and to compare their performance with that of prostheses provided with conventional cast frameworks. On a routine basis, a consecutive group of 824 edentulous patients were provided with fixed prostheses supported by implants in the edentulous mandible. In addition to conventional gold-alloy castings, patients were at random provided with 2 kinds of laser-welded titanium frameworks. In all, 155 patients were included in the 2 titanium framework groups. A control group of 53 randomly selected patients with conventional gold-alloy castings was used for comparison. Clinical and radiographic 5-year data was collected for the 3 groups. All followed patients still had fixed prostheses in the mandible after 5 years. The overall cumulative success rates were 95.9% and 99.7% for titanium-framework prostheses and implants, respectively. The corresponding success rates for the control group were 100% and 99.6%, respectively. Bone loss was 0.5 mm on average during the 5-year follow-up period. The most common complications for titanium frameworks were resin or tooth fractures, gingival inflammation, and fractures of the metal frames (10%). One of the cast frameworks fractured and was resoldered. Loose and fractured implant screw components were few (< 1%). Even though the cast frameworks had a higher success rate, the overall titanium framework treatment result was well in accordance with the result of the control group. The test groups performed better after clinicians had gained some experience with the technique, and laser-welded titanium frameworks seem to be a viable alternative to conventional castings in the edentulous mandible.

  19. Awareness, attitudes, need and demand on replacement of missing teeth among a group of partially dentate patients attending a University Dental Hospital.

    PubMed

    Jayasinghe, Rasika Manori; Perera, Janana; Jayasinghe, Vajira; Thilakumara, Indika P; Rasnayaka, Sumudu; Shiraz, Muhammad Hanafi Muhammad; Ranabahu, Indra; Kularatna, Sanjeewa

    2017-07-27

    Our objective was to assess awareness, attitudes, need and demand on replacement of missing teeth according to edentulous space, age, gender, ethnicity, educational level and socio-economical status of the patient. 76.2% of the study group was opined that the missing teeth should be replaced by prosthetic means. Majority were keen in getting them replaced mainly for the comfort in mastication. Although 77.9 and 32.9% were aware of the removable prostheses and implants respectively, only 25.2% knew about tooth supported bridges as an option of replacement of missing teeth. Participants' awareness on tooth and implant supported prostheses is at a higher level. Participants' opinion on need of regular dental visit was statistically significant when gender, ethnicity and education level were considered. The highest demand for replacement of missing teeth was observed in Kennedy class I and II situations in both upper and lower arches. Demand for fixed prostheses was significantly highest in Kennedy class II in upper and lower arches. In conclusion, although removable prosthodontic options are known to most of the patients, their awareness on tooth and implant supported prostheses is also at a higher level. The highest demand for replacement of missing teeth is by patients with Kennedy class I and II situations whereas Kennedy class II being the category with highest demand for fixed prostheses. We recommend that the location of missing teeth to be considered as a priority when educating patients on the most appropriate prosthetic treatment options. Dentists' involvement in educating patients on prosthetic options needs to be improved.

  20. Fracture load of complete-arch implant-supported prostheses reinforced with nylon-silica mesh: An in vitro study.

    PubMed

    Gonçalves, Fernanda de Cássia Papaiz; Amaral, Marina; Borges, Alexandre Luiz Souto; Gonçalves, Luiz Fernando Martins; Paes-Junior, Tarcisio José de Arruda

    2018-04-01

    Complete-arch implant-supported prostheses without a framework have a high risk of failure: a straightforward and inexpensive reinforcement material, such as nylon mesh, could improve their longevity. The purpose of this in vitro study was to evaluate a nylon-silica mesh compound on the fracture strength of acrylic resin and the fracture load of complete-arch implant-supported prostheses. Twenty-four complete mandibular arch implant-supported prostheses were divided into 2 groups according to cantilever length (molar and premolar) and subdivided into another 2 subgroups according to the presence or absence of reinforcing mesh. The specimens were submitted to a maximum load-to-fracture test in a universal testing machine, with a 100-N load cell, a 2 mm/min crosshead speed, and a spherical metal tip diameter of 4 mm at different points (molar and premolar). These were submitted to 1-way analysis of variance for repeated measurement and the post hoc Tukey multiple comparison test (α=.05). The mean maximum load ±standard deviation for the molar group was 393.4 ±95.0 N with reinforcement and 305.4 ±76.3 N without reinforcement (P=.02); and for the premolar group was 1083.3 ±283.7 N with reinforcement and 605.3 ±90.5 N without reinforcement (P=.001). Reinforcement with nylon mesh increased the mean maximum load of implant-supported complete-arch prostheses at both cantilever lengths. The cantilever to the premolar (5 mm) presented the highest maximum load values to fracture. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  1. Three-dimensional printed upper-limb prostheses lack randomised controlled trials: A systematic review

    PubMed Central

    Diment, Laura E; Thompson, Mark S; Bergmann, Jeroen HM

    2017-01-01

    Background: Three-dimensional printing provides an exciting opportunity to customise upper-limb prostheses. Objective: This review summarises the research that assesses the efficacy and effectiveness of three-dimensional printed upper-limb prostheses. Study design: Systematic review. Methods: PubMed, Web of Science and OVID were systematically searched for studies that reported human trials of three-dimensional printed upper-limb prostheses. The studies matching the language, peer-review and relevance criteria were ranked by level of evidence and critically appraised using the Downs and Black Quality Index. Results: After removing duplicates, 321 records were identified. Eight papers met the inclusion criteria. No studies used controls; five were case studies and three were small case-series studies. All studies showed promising results, but none demonstrated external validity, avoidance of bias or statistically significant improvements over conventional prostheses. The studies demonstrated proof-of-concept rather than assessing efficacy, and the devices were designed to prioritise reduction of manufacturing costs, not customisability for comfort and function. Conclusion: The potential of three-dimensional printing for individual customisation has yet to be fully realised, and the efficacy and effectiveness to be rigorously assessed. Until randomised controlled trials with follow-up are performed, the comfort, functionality, durability and long-term effects on quality of life remain unknown. Clinical relevance Initial studies suggest that three-dimensional printing shows promise for customising low-cost upper-limb prosthetics. However, the efficacy and effectiveness of these devices have yet to be rigorously assessed. Until randomised controlled trials with follow-up are performed, the comfort, functionality, durability and long-term effects on patient quality of life remain unknown. PMID:28649911

  2. Current evaluation of hydraulics to replace the cable force transmission system for body-powered upper-limb prostheses.

    PubMed

    LeBlanc, M

    1990-01-01

    Present body-powered upper-limb prostheses use a cable control system employing World War II aircraft technology to transmit force from the body to the prosthesis for operation. The cable and associated hardware are located outside the prosthesis. Because individuals with arm amputations want prostheses that are natural looking with a smooth, soft outer surface, a design and development project was undertaken to replace the cable system with hydraulics located inside the prosthesis. Three different hydraulic transmission systems were built for evaluation, and other possibilities were explored. Results indicate that a hydraulic force transmission system remains an unmet challenge as a practical replacement for the cable system. The author was unable to develop a hydraulic system that meets the necessary dynamic requirements and is acceptable in size and appearance.

  3. Recording of Electric Signal Passing Through a Pylon in Direct Skeletal Attachment of Leg Prostheses with Neuromuscular Control

    PubMed Central

    Pitkin, M.; Cassidy, C.; Muppavarapu, R.; Edell, David

    2012-01-01

    Direct recordings were made of electrical signals emanating from the muscles in a rabbit’s residuum. The signals were transmitted via wires attached on one end to the muscles, and on the other to an external recording system. The cable was held in a titanium tube inside a pylon that had been transcutaneously implanted into the residuum’s bone. The tube was surrounded by porous titanium cladding to enhance its bond with the bone and with the skin of the residuum. This study was the first known attempt to merge the technology of direct skeletal attachment of limb prostheses with the technology of neuromuscular control of prostheses, providing a safe and reliable passage of the electrical signal from the muscles inside the residuum to the outside recording system. PMID:22345523

  4. Design of a hip prosthetic tribometer based on salat gait cycle

    NASA Astrophysics Data System (ADS)

    Towijaya, T.; Ismail, R.; Jamari, J.

    2017-01-01

    Indonesia is the country with the largest muslim population in the world, most of the inhabitants do salat every day. THR (Total Hip Replacement) patients are prohibited from doing salat in normal gait. It leads to the damage of the hip joint prostheses due to impingement and dislocation.This paper reports the design of a pin-on-ring tribometer which is used to measure and analyze the wear volume and the impingement of hip joint prostheses during salat. The modifications of the femoral head and acetabular cup holder are performed to design the reciprocating motion for the movement of the hip prostheses. The interesting finding of the present research is a new mechanism of linked-bar which leads to the feasibility of the measurement of the wear volume and the impingement for THR patients during salat.

  5. Engineering of a multi-station shoulder simulator.

    PubMed

    Smith, Simon L; Li, Lisa; Joyce, Thomas J

    2016-05-01

    This work aimed to engineer a multi-station shoulder simulator in order to wear test shoulder prostheses using recognized shoulder activities of daily living. A bespoke simulator was designed, built and subject to commissioning trials before a first wear test was conducted. Five JRI Orthopaedics Reverse Shoulder VAIOS 42 mm prostheses were tested for 2.0 million cycles and a mean wear rate and standard deviation of 14.2 ± 2.1 mm(3)/10(6) cycles measured for the polymeric glenoid components. This result when adjusted for prostheses diameters and test conditions showed excellent agreement with results from hip simulator studies of similar materials in a lubricant of bovine serum. The Newcastle Shoulder Simulator is the first multi-station shoulder simulator capable of applying physiological motion and loading for typical activities of daily living. © IMechE 2016.

  6. Embodying prostheses - how to let the body welcome assistive devices. Comment on "The embodiment of assistive devices-from wheelchair to exoskeleton" by M. Pazzaglia and M. Molinari

    NASA Astrophysics Data System (ADS)

    Longo, Matthew R.; Sadibolova, Renata; Tamè, Luigi

    2016-03-01

    A growing body of research has focused on the development of assistive devises to improve the recovery and ameliorate the quality of life of people suffering from spinal cord injuries (SCI). In their stimulating and timely paper, Pazzaglia and Molinari [1] review the significant progress made by biotechnology studies in providing increasing sophisticated assistive tools (e.g., prostheses and exoskeletons) that extend the functionality of patients' bodies. However, despite this extraordinary technological effort [2], it remains uncertain how these devices can be appropriately embedded into the mental representation of the body. Here, we wish to amplify the points raised by Pazzaglia and Molinari by discussing three challenges facing work on embodying prostheses raised by experimental research on body representation.

  7. [On the history of cementless implants in extremity surgery].

    PubMed

    Dufek, Pavel

    2017-05-01

    The aim of implantation of cementless hip prostheses is vital ingrowth of bone into the structured metal surface of the implant. Since the 1960s several implants with surfaces made of cobalt-based alloys have been produced for this purpose. In the 1980s a novel hip endoprosthesis with a spongiosa-metal surface was introduced. The three-dimensional ingrowth of bone tissue into the structured surface of the implant could be demonstrated both histologically and using scanning electron microscopy (SEM). These implants made of cobalt-based alloys can also be used in endo-exo prostheses. Titanium implants with a microstructured surface have also been used and very good osseintegration of the surface was also demonstrated by histomorphology. The optimization of the surface and design of the prostheses plays an increasingly more important role in the field of revision endoprostheses.

  8. Testicular Prostheses: Development and Modern Usage

    PubMed Central

    Bodiwala, D; Summerton, DJ; Terry, TR

    2007-01-01

    INTRODUCTION Testicular prostheses produced from various materials have been in use since 1941. The absence of a testicle has been shown to be a psychologically traumatic experience for males of all ages. The indications for insertion of a prosthesis include absence or following orchidectomy from a number of causes such as malignancy, torsion and orchitis. The most common substance used around the world in the manufacture of these implants is silicone; however, in the US, this material is currently banned because of theoretical health risks. This has led to the development of saline-filled prostheses as an alternative. PATIENTS AND METHODS A Medline search was carried out on all articles on testicular prosthesis between 1966 and 2006. CONCLUSIONS This review highlights the controversies regarding prosthetic materials, the complications of insertion and the potential benefits of this commonly performed procedure. PMID:17535609

  9. The crimping problem in stapes surgery.

    PubMed

    Kwok, Pingling; Fisch, Ugo; Strutz, Jürgen

    2007-01-01

    The goal of this study was to compare the attachment of stapes prostheses with differently shaped loops to the long process of the incus. Gold, steel/Teflon, platinum/Teflon, and two different titanium stapes prostheses were inserted in 30 specially prepared temporal bones by three experienced surgeons using the Fisch technique with the McGee crimper and straight alligator forceps for the crimping of the loops. In all prostheses, a sufficiently firm attachment of the long process of the incus was achieved. The band-shaped loops showed a better contact with the incus than did the wire loops. However, the broad spiral-shaped loops led to a loss of the perpendicular axis of the piston to the long incus process. The geometry of the loop affects the final length of the piston in the vestibule and its angle to the long process of the incus.

  10. Materials testing protocol for small joint prostheses.

    PubMed

    Savory, K M; Hutchinson, D T; Bloebaum, R

    1994-10-01

    In this article, a protocol for the evaluation of new materials for small joint prostheses is introduced. The testing methods employed in the protocol were developed by reviewing reported clinical failure modes and conditions found in vivo. The methods developed quantitatively evaluates the fatigue, fatigue crack propagation, and wear resistance properties of materials. For this study, a silicone elastomer similar to Dow Corning Silastic HP100, a radiation stable polypropylene, and a copolymer of polypropylene and ethylene propylene-diene monomer (EPDM) are evaluated. None of the materials tested demonstrated the ideal properties that are sought in a self-hinging joint prostheses. The silicone elastomer had excellent wear properties; however, cracks quickly propagated, causing catastrophic failure when fatigued. Conversely, the copolymer showed excellent fatigue crack propagation resistance and less than favorable wear properties. The polypropylene did not perform well in any evaluation.

  11. The development of artificial organs and prostheses worldwide and in the Ottoman Empire.

    PubMed

    Birdane, Leman; Cingi, Cemal; Elçioğlu, Ömür; Muluk, Nuray Bayar

    2016-08-01

    An artificial organ or prosthesis is a man-made device that is implanted or integrated into a human to replace a natural organ. There were many historical steps in the development of artificial organs and prostheses. New surgical techniques, the development of prosthetic materials and the creative ideas of engineers led to progress in this field. © The European Society of Cardiology 2014.

  12. Determining the Potential Benefit of Powered Prostheses

    DTIC Science & Technology

    2016-10-01

    CA184478-01 04/11/2014–03/31/2017 0.15 calendar months NIH/NCI $50,000 (No- cost extension) Impact of public housing assistance on... benefits of direct observation while significantly reducing the time and cost burden associated with training and monitoring field staff. Role: Principal...AWARD NUMBER: W81XWH-15-1-0548 TITLE: Determining the Potential Benefit of Powered Prostheses PRINCIPAL INVESTIGATOR: Deanna H. Gates

  13. Malrotation of the McGhan Style 510 prosthesis.

    PubMed

    Schots, Jeroen M P; Fechner, Maarten R; Hoogbergen, Maarten M; van Tits, Herm W H J

    2010-07-01

    Anatomically shaped cohesive silicone breast implants are frequently used in aesthetic and reconstructive surgery. After successful results with the Style 410 prosthesis, McGhan (Natrelle, Allergan) introduced the Style 510 prosthesis. After using this novel prosthesis, the authors encountered a high number of prosthesis malrotations on self-reported follow-up. Therefore, a retrospective medical record review was performed to determine the prevalence of malrotation of the Style 510 prosthesis. From January of 2005 to December of 2006, 73 (146 prostheses) aesthetic augmentation mammaplasty procedures were performed using Style 510 prostheses. All prostheses were placed subglandularly through an inframammary incision. The postsurgical protocol for the first 3 weeks involved wearing a nonwired compression bra, abstinence from sports activities, and abstinence from heavy labor. Standard follow-up was at 1 week, 3 months, and if necessary. On self-reported follow-up, 8.2 percent of all prostheses were rotated. These rotations all occurred unilaterally after a mean period of 10 months (range, 3 to 19 months). No relation to an inciting incident or prosthesis volume could be found. The number of rotations of the Style 510 prosthesis seen after primary aesthetic breast augmentation is high. An obvious cause of this major problem has not been found. This led the authors to discontinue using the Style 510 prosthesis for primary aesthetic mammary augmentations in their practice.

  14. Biofilm formation and design features of indwelling silicone rubber tracheoesophageal voice prostheses--an electron microscopical study.

    PubMed

    Leunisse, C; van Weissenbruch, R; Busscher, H J; van der Mei, H C; Dijk, F; Albers, F W

    2001-01-01

    After total laryngectomy, voice can be restored with a silicone rubber tracheoesophageal voice prosthesis. However, biofilm formation and subsequent deterioration of the silicone material of the prosthesis will limit device life by impairing valve function. To simulate the natural process of biofilm development under dynamic nutrient conditions, a modified Robbins device was used to evaluate the biofilm-related valve dysfunction of the Groningen, Provox2, Blom-Singer indwelling, and VoiceMaster voice prostheses. Obstruction of the semicircular slit-valved Groningen prosthesis leading to increased airway resistance was caused not only by a buildup of deposits on the esophageal flange and valve hat, but also by accumulation of deposits on the semicircular valve seating. The hinged flap valved Provox2 and indwelling Blom-Singer prostheses failed to close sufficiently because of biofilm formation on the valve seating. The esophageal flange of the VoiceMaster prosthesis was affected, but the tripod structure of the ball valve was fully colonized up to the titanium sleeve, which interfered with proper valve opening and closure. These findings on biofilm formation could be used for the further development and modification of critical design features of voice prostheses to facilitate tracheoesophageal speech. Copyright 2001 John Wiley & Sons, Inc.

  15. Is it Finger or Wrist Dexterity That is Missing in Current Hand Prostheses?

    PubMed

    Montagnani, Federico; Controzzi, Marco; Cipriani, Christian

    2015-07-01

    Building prostheses with dexterous motor function equivalent to that of the human hand is one of the ambitious goals of bioengineers. State of art prostheses lack several degrees of freedom (DoF) and force the individuals to compensate for them by changing the motions of their arms and body. However, such compensatory movements often result in residual limb pain and overuse syndromes. Significant efforts were spent in designing artificial hands with multiple allowed grasps but little work has been done with regards to wrist design, regardless the fact that the wrist contributes significantly to the execution of upper limb motor tasks. We hypothesized that a single DoF hand with wrist flexion/extension allowed function comparable to a highly performant multi DoF hand without wrist flexion/extension. To assess this we compared four emulated architectures of hand-wrist prostheses using the Southampton Hand Assessment Procedure and evaluating the extent of compensatory movements with unimpaired subjects wearing ortheses. Our findings show indeed that shifting the dexterity from the hand to the wrist could preserve the ability of transradial amputees in performing common tasks with limited effect on the compensatory movements. Hence, this study invites rehabilitation engineers to focus on novel artificial wrist architectures.

  16. Quality of life in patients with obturator prostheses.

    PubMed

    Riaz, Nabeela; Warriach, Riaz Ahmad

    2010-01-01

    Oral cancer has a profound impact on the quality of life for patients and their families. Functionally, the mouth is an important organ for speech, swallowing, chewing, taste and salivation. These functions become compromised due to surgical ablation of the tumour. Obturator prosthesis is a common prosthdontic rehabilitative option for maxillectomy patients. The purpose of this study was to investigate how patients with maxillofacial defects evaluate their quality of life after maxillectomy and prosthodontic therapy with obturator prostheses. Thirty patients were included in the study (11 female, 19 male). The patients were interviewed by using a standardised questionnaire developed by University of Washington (UW-QOL). The detailed questionnaire was adjusted for obturator patients and internalised most parts of obturator functioning scale (OFS). Quality of life after prosthodontic therapy with obturator prostheses was 54 +/- 22.9% on average. Functioning of the obturator prosthesis, impairment of ingestion, speech and appearance, the extent of therapy, and the existence of pain had significant impact on the quality of life (p<0.005). Orofacial rehabilitation of patients with maxillofacial defects using obturator prostheses is an appropriate treatment modality. To improve the situation of patients prior to and after maxillectomy sufficient information about the treatment, adequate psychological care and speech therapy should be provided.

  17. Cementless Hydroxyapatite Coated Hip Prostheses

    PubMed Central

    Herrera, Antonio; Mateo, Jesús; Gil-Albarova, Jorge; Lobo-Escolar, Antonio; Ibarz, Elena; Gabarre, Sergio; Más, Yolanda

    2015-01-01

    More than twenty years ago, hydroxyapatite (HA), calcium phosphate ceramics, was introduced as a coating for cementless hip prostheses. The choice of this ceramic is due to its composition being similar to organic apatite bone crystals. This ceramic is biocompatible, bioactive, and osteoconductive. These qualities facilitate the primary stability and osseointegration of implants. Our surgical experience includes the implantation of more than 4,000 cementless hydroxyapatite coated hip prostheses since 1990. The models implanted are coated with HA in the acetabulum and in the metaphyseal area of the stem. The results corresponding to survival and stability of implants were very satisfactory in the long-term. From our experience, HA-coated hip implants are a reliable alternative which can achieve long term survival, provided that certain requirements are met: good design selection, sound choice of bearing surfaces based on patient life expectancy, meticulous surgical technique, and indications based on adequate bone quality. PMID:25802848

  18. Clinical experience with fibrin glue in cardiac surgery.

    PubMed

    Köveker, G; de Vivie, E R; Hellberg, K D

    1981-10-01

    Cardiac surgery is often associated with hemostatic abnormalities leading to severe bleeding. Special problems are to be expected, if prosthetic material has to be implanted. Preclotting of Dacron prostheses with blood is well established but failures are sometimes encountered. Several years ago a new hemostatic sealing system (fibrin glue) was introduced into therapy. Since 1978 fibrin glue has been applied in 176 patients. The indications were: 1. sealing of woven Dacron prostheses, 2. bleeding from suture-holes (Gore-Tex), 3. diffuse myocardial bleeding and 4. prevention of kinking of coronary artery grafts. In 32 patients with an aortoventriculoplasty operation using Dacron the "blood preclotting" and "fibrin sealing" methods were compared. In the fibrin glue group there was a significant reduction in postoperative blood loss as well as a shortening of the operation time (period of protamin administration to skin closure). No fibrinolytic dissolution of the fibrin layer on the prostheses was observed.

  19. Are prosthetic heart valve fibrin strands negligible? The associations and significance.

    PubMed

    Kiavar, Majid; Sadeghpour, Anita; Bakhshandeh, Hooman; Tayyebi, Parisa; Bassiri, Hossein Ali; Esmaeilzadeh, Maryam; Maleki, Majid; Noohi, Feridoun

    2009-08-01

    Filamentous fibrin strands (FSs) attached to valve prostheses have been well described in patients undergoing transesophageal echocardiography, but the frequency and clinical significance of these strands remain poorly defined. The aims of this study were to determine the frequency of prosthetic valve strands and to assess their significance in relation to clinical cerebral ischemic events (CIEs) and anticoagulant status. Three hundred consecutive patients with 421 prosthetic heart valves were evaluated for the presence of FSs (highly mobile, filamentous masses<1 mm thick). FSs were found in 139 patients (49%) and 147 prostheses (38%) in patients with left-sided prostheses, with a significant association between FSs, CIEs, and anticoagulant status (P<.001). A lower international normalized ratio (<2.5) had a positive association with the occurrence of CIEs. There is a significant association between FSs, CIEs, and patient's anticoagulant status; therefore, aggressive anticoagulation and close follow-up are recommended for these patients.

  20. Recent Patents and Designs on Hip Replacement Prostheses

    PubMed Central

    Derar, H; Shahinpoor, M

    2015-01-01

    Hip replacement surgery has gone through tremendous evolution since the first procedure in 1840. In the past five decades the advances that have been made in technology, advanced and smart materials innovations, surgical techniques, robotic surgery and methods of fixations and sterilization, facilitated hip implants that undergo multiple design revolutions seeking the least problematic implants and a longer survivorship. Hip surgery has become a solution for many in need of hip joint remedy and replacement across the globe. Nevertheless, there are still long-term problems that are essential to search and resolve to find the optimum implant. This paper reviews several recent patents on hip replacement surgery. The patents present various designs of prostheses, different materials as well as methods of fixation. Each of the patents presents a new design as a solution to different issues ranging from the longevity of the hip prostheses to discomfort and inconvenience experienced by patients in the long-term. PMID:25893020

  1. A new Ti-5Ag alloy for customized prostheses by three-dimensional printing (3DP).

    PubMed

    Hong, S B; Eliaz, N; Leisk, G G; Sach, E M; Latanision, R M; Allen, S M

    2001-03-01

    Three important considerations in the fabrication of customized cranio-maxillofacial prostheses are geometric precision, material strength, and biocompatibility. Three-dimensional printing (3DP) is a rapid part-fabrication process that can produce complex parts with high precision. The aim of this study was to design, synthesize by 3DP, and characterize a new Ti-5Ag (wt%) alloy. Silver nitrate was found to be an appropriate inorganic binder for the Ti powder-based skeleton, and the optimum sintering parameters for full densification were determined. The hardness of the Ti-5Ag alloy was shown to be much higher than that of a pure titanium sample. Potentiodynamic measurements, carried out in saline solution at body temperature, showed that the Ti-5Ag alloy had good passivation behavior, similar to that of pure titanium. It is concluded that the Ti-Ag system may be suitable for fabrication of customized prostheses by 3DP.

  2. Evolution of penile prosthetic devices

    PubMed Central

    Burnett, Arthur L.

    2015-01-01

    Penile implant usage dates to the 16th century yet penile implants to treat erectile dysfunction did not occur until nearly four centuries later. The modern era of penile implants has progressed rapidly over the past 50 years as physicians' knowledge of effective materials for penile prostheses and surgical techniques has improved. Herein, we describe the history of penile prosthetics and the constant quest to improve the technology. Elements of the design from the first inflatable penile prosthesis by Scott and colleagues and the Small-Carrion malleable penile prosthesis are still found in present iterations of these devices. While there have been significant improvements in penile prosthesis design, the promise of an ideal prosthetic device remains elusive. As other erectile dysfunction therapies emerge, penile prostheses will have to continue to demonstrate a competitive advantage. A particular strength of penile prostheses is their efficacy regardless of etiology, thus allowing treatment of even the most refractory cases. PMID:25763121

  3. Evolution of penile prosthetic devices.

    PubMed

    Le, Brian; Burnett, Arthur L

    2015-03-01

    Penile implant usage dates to the 16th century yet penile implants to treat erectile dysfunction did not occur until nearly four centuries later. The modern era of penile implants has progressed rapidly over the past 50 years as physicians' knowledge of effective materials for penile prostheses and surgical techniques has improved. Herein, we describe the history of penile prosthetics and the constant quest to improve the technology. Elements of the design from the first inflatable penile prosthesis by Scott and colleagues and the Small-Carrion malleable penile prosthesis are still found in present iterations of these devices. While there have been significant improvements in penile prosthesis design, the promise of an ideal prosthetic device remains elusive. As other erectile dysfunction therapies emerge, penile prostheses will have to continue to demonstrate a competitive advantage. A particular strength of penile prostheses is their efficacy regardless of etiology, thus allowing treatment of even the most refractory cases.

  4. Economic Evaluation of the Combined Use of Warfarin and Low-dose Aspirin Versus Warfarin Alone in Mechanical Valve Prostheses.

    PubMed

    El-Hamamsy, Manal H; Elsisi, Gihan H; Eldessouki, Randa; Elmazar, Mohamed M; Taha, Ahmed S; Awad, Basma F; Elmansy, Hossam

    2016-08-01

    The use of combined therapy of antiplatelet and anticoagulant versus anticoagulant alone to reduce instances of thromboembolic events in patients with heart valve prostheses is an established standard of care in many countries but not in Egypt. A previous Markov model cost-effectiveness study on Egyptian patients aged 50-60 years demonstrated that the combined therapy reduces the overall treatment cost. However, due to the lack of actual real-world data on cost-effectiveness and the limitation of the Markov model study to 50- to 60-year-old patients, the Egyptian medical community is still questioning whether the added benefit is worth the cost. To assess, from the perspective of the Egyptian health sector, the cost-effectiveness of the combined use of warfarin and low-dose aspirin (75 mg) versus that of warfarin alone in patients with mechanical heart valve prostheses who began therapy between the age of 15 and 50 years. An economic evaluation was conducted alongside a randomized, controlled trial to assess the cost-effectiveness of the combined therapy in patients with mechanical valve prostheses. A total of 316 patients aged between 15 and 50 years were included in the study and randomly assigned to a group treated with both warfarin and aspirin or a group treated with warfarin alone. The patients in the combined therapy group exhibited a significantly longer duration of protection against the first event. Fewer primary events were observed in the patients treated with warfarin plus aspirin than in those treated with warfarin alone (1.4 %/year, vs. 4.8 %/year), and a higher mean quality-adjusted life-years (QALYs) value over 4 years was obtained for the group treated with warfarin plus aspirin (difference 0.058; 95 % CI 0.013-0.118), although this difference did not reach a conventional level of statistical significance. The total costs over a 4-year period were lower with the combined therapy (difference -US$244; 95 % CI -US$483.1 to -US$3.8), which yielded an incremental cost-effectiveness ratio of -US$4206 per QALY gained. Thus, the combined therapy was dominant. All costs were reported in US dollars (USD) for the financial year 2014. The results of this analysis indicate that from the perspective of the Egyptian health sector, the addition of aspirin to the typical warfarin therapy is more effective and less costly for patients with mechanical valve prostheses than treatment with warfarin alone. This combined strategy could be adopted to prevent the complications of mechanical valve prostheses. Our study adds to the body of evidence supporting the option of warfarin-plus-aspirin therapy for patients with mechanical valve prostheses.

  5. Children with congenital limb deficiency in Norway: issues related to school life and health-related quality of life. A cross-sectional study.

    PubMed

    Johansen, Heidi; Dammann, Brede; Øinæs Andersen, Liv; Andresen, Inger-Lise

    2016-09-01

    To describe clinical features, issues related to school life and health-related quality of life (HRQOL) for children with congenital limb deficiency (CLD) and compare these children to Norwegian school children on HRQOL. Cross-sectional study. In 2010, a postal questionnaire, designed for this study and the Paediatric Quality of Life Inventory (PedsQL), was sent to 154 eligible parents of children with CLD, aged 6-18 years and registered at TRS National Resource Centre for Rare Disorders in Norway. Response rate 44% (n = 67), median age 11 years, 42% were girls. Of the total group, 46 had unilateral upper limb deficiency (UULD) and 21 had multiple/lower limb deficiency (MLD/LLD). The most common UULD was below-elbow deficiency, of these, 65% used grip-improving devices, and 35% used prostheses. Children with UULD-reported PedsQL score similar to Norwegian schoolchildren (NSC). The MLD/LLD group was heterogeneous; most had below-elbow/knee deficiency. In this group, PedsQL scores were reduced for physical and social functioning compared with NSC. Compared with children with UULD, more children with MLD/LLD were restricted in participation because of pain and fewer participated in physical education with peers. Most children with CLD participated with their peers and managed well in everyday life. Children with MLD/LLD seemed to have more challenges than children with UULD. Approximately one-third of all the children had assistive devices and/or practical assistance in school. Implications for Rehabilitation Most children with upper-limb deficiency (UULD) in Norway manage well in everyday life and have HRQOL equal to other Norwegian children. Many choose grip-improving devices instead of prostheses. Their preferences should be respected and taken into account as the need for new assistive devices arise. For children with pronounced disabilities, access to, and use of, assistive devices, adaptions and practical assistance may be important for participation. Cooperation with the child and the parents is necessary to find useful measures. Physical education and practical subjects may provide special challenges, both for children and their teachers. Children themselves often find good solutions and the tasks should be planned ahead in cooperation with them.

  6. Stabilization of a three-dimensional limit cycle walking model through step-to-step ankle control.

    PubMed

    Kim, Myunghee; Collins, Steven H

    2013-06-01

    Unilateral, below-knee amputation is associated with an increased risk of falls, which may be partially related to a loss of active ankle control. If ankle control can contribute significantly to maintaining balance, even in the presence of active foot placement, this might provide an opportunity to improve balance using robotic ankle-foot prostheses. We investigated ankle- and hip-based walking stabilization methods in a three-dimensional model of human gait that included ankle plantarflexion, ankle inversion-eversion, hip flexion-extension, and hip ad/abduction. We generated discrete feedback control laws (linear quadratic regulators) that altered nominal actuation parameters once per step. We used ankle push-off, lateral ankle stiffness and damping, fore-aft foot placement, lateral foot placement, or all of these as control inputs. We modeled environmental disturbances as random, bounded, unexpected changes in floor height, and defined balance performance as the maximum allowable disturbance value for which the model walked 500 steps without falling. Nominal walking motions were unstable, but were stabilized by all of the step-to-step control laws we tested. Surprisingly, step-by-step modulation of ankle push-off alone led to better balance performance (3.2% leg length) than lateral foot placement (1.2% leg length) for these control laws. These results suggest that appropriate control of robotic ankle-foot prosthesis push-off could make balancing during walking easier for individuals with amputation.

  7. Kinetics of transfemoral amputees with osseointegrated fixation performing common activities of daily living.

    PubMed

    Lee, Winson C C; Frossard, Laurent A; Hagberg, Kerstin; Haggstrom, Eva; Brånemark, Rickard; Evans, John H; Pearcy, Mark J

    2007-07-01

    Direct anchorage of a lower-limb prosthesis to the bone through an implanted fixation (osseointegration) has been suggested as an excellent alternative for amputees experiencing complications from use of a conventional socket-type prosthesis. However, an attempt needs to be made to optimize the mechanical design of the fixation and refine the rehabilitation program. Understanding the load applied on the fixation is a crucial step towards this goal. The load applied on the osseointegrated fixation of nine transfemoral amputees was measured using a load transducer, when the amputees performed activities which included straight-line level walking, ascending and descending stairs and a ramp as well as walking around a circle. Force and moment patterns along each gait cycle, magnitudes and time of occurrence of the local extrema of the load, as well as impulses were analysed. Managing a ramp and stairs, and walking around a circle did not produce a significant increase (P>0.05) in load compared to straight-line level walking. The patterns of the moment about the medio-lateral axis were different among the six activities which may reflect the different strategies used in controlling the prosthetic knee joint. This study increases the understanding of biomechanics of bone-anchored osseointegrated prostheses. The loading data provided will be useful in designing the osseointegrated fixation to increase the fatigue life and to refine the rehabilitation protocol.

  8. Fully phase-encoded MRI near metallic implants using ultrashort echo times and broadband excitation.

    PubMed

    Wiens, Curtis N; Artz, Nathan S; Jang, Hyungseok; McMillan, Alan B; Koch, Kevin M; Reeder, Scott B

    2018-04-01

    To develop a fully phase-encoded MRI method for distortion-free imaging near metallic implants, in clinically feasible acquisition times. An accelerated 3D fully phase-encoded acquisition with broadband excitation and ultrashort echo times is presented, which uses a broadband radiofrequency pulse to excite the entire off-resonance induced by the metallic implant. Furthermore, fully phase-encoded imaging is used to prevent distortions caused by frequency encoding, and to obtain ultrashort echo times for rapidly decaying signal. Phantom and in vivo acquisitions were used to describe the relationship among excitation bandwidth, signal loss near metallic implants, and T 1 weighting. Shorter radiofrequency pulses captured signal closer to the implant by improving spectral coverage and allowing shorter echo times, whereas longer pulses improved T 1 weighting through larger maximum attainable flip angles. Comparisons of fully phase-encoded acquisition with broadband excitation and ultrashort echo times to T 1 -weighted multi-acquisition with variable resonance image combination selective were performed in phantoms and subjects with metallic knee and hip prostheses. These acquisitions had similar contrast and acquisition efficiency. Accelerated fully phase-encoded acquisitions with ultrashort echo times and broadband excitation can generate distortion free images near metallic implants in clinically feasible acquisition times. Magn Reson Med 79:2156-2163, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  9. Fully Phase-Encoded MRI Near Metallic Implants Using Ultrashort Echo Times and Broadband Excitation

    PubMed Central

    Wiens, Curtis N.; Artz, Nathan S.; Jang, Hyungseok; McMillan, Alan B.; Koch, Kevin M.; Reeder, Scott B.

    2017-01-01

    Purpose To develop a fully phase-encoded MRI method for distortion-free imaging near metallic implants, in clinically feasible acquisition times. Theory and Methods An accelerated 3D fully phase-encoded acquisition with broadband excitation and ultrashort echo times is presented, which uses a broadband radiofrequency pulse to excite the entire off-resonance induced by the metallic implant. Furthermore, fully phase-encoded imaging is used to prevent distortions caused by frequency encoding, and to obtain ultrashort echo times for rapidly decaying signal. Results Phantom and in vivo acquisitions were used to describe the relationship among excitation bandwidth, signal loss near metallic implants, and T1 weighting. Shorter radiofrequency pulses captured signal closer to the implant by improving spectral coverage and allowing shorter echo times, whereas longer pulses improved T1 weighting through larger maximum attainable flip angles. Comparisons of fully phase-encoded acquisition with broadband excitation and ultrashort echo times to T1-weighted multi-acquisition with variable resonance image combination selective were performed in phantoms and subjects with metallic knee and hip prostheses. These acquisitions had similar contrast and acquisition efficiency. Conclusions Accelerated fully phase-encoded acquisitions with ultrashort echo times and broadband excitation can generate distortion free images near metallic implants in clinically feasible acquisition times. Magn Reson Med 000:000–000, 2017. PMID:28833407

  10. Tribo-electrochemical characterization of metallic biomaterials for total joint replacement.

    PubMed

    Diomidis, N; Mischler, S; More, N S; Roy, Manish

    2012-02-01

    Knee and hip joint replacement implants involve a sliding contact between the femoral component and the tibial or acetabular component immersed in body fluids, thus making the metallic parts susceptible to tribocorrosion. Micro-motions occur at points of fixation leading to debris and ion release by fretting corrosion. β-Titanium alloys are potential biomaterials for joint prostheses due to their biocompatibility and compatibility with the mechanical properties of bone. The biotribocorrosion behavior of Ti-29Nb-13Ta-4.6Zr was studied in Hank's balanced salt solution at open circuit potential and at an applied potential in the passive region. Reciprocating sliding tribocorrosion tests were carried out against technical grade ultra high molecular weight polyethylene, while fretting corrosion tests were carried out against alumina. The wear of the alloy is insignificant when sliding against polyethylene. However, depassivation does take place, but the tested alloy showed an ability to recover its passive state during sliding. The abrasivity of the alloy depends on the electrochemical conditions of the contact, while the wear of polyethylene proceeds through third body formation and material transfer. Under fretting corrosion conditions recovery of the passive state was also achieved. In a fretting contact wear of the alloy proceeds through plastic deformation of the bulk material and wear resistance depends on the electrochemical conditions. Copyright © 2011 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  11. Acrylic resin guide for locating the abutment screw access channel of cement-retained implant prostheses.

    PubMed

    Ahmed, Ayman; Maroulakos, Georgios; Garaicoa, Jorge

    2016-05-01

    Abutment screw loosening represents a common and challenging technical complication of cement-retained implant prostheses. This article describes the fabrication of a simple and accurate poly(methyl methacrylate) guide for identifying the location and angulation of the abutment screw access channel of a cement-retained implant prosthesis with a loosened abutment screw. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  12. Workflow Optimization for Tuning Prostheses with High Input Channel

    DTIC Science & Technology

    2017-10-01

    of Specific Aim 1 by driving a commercially available two DoF wrist and single DoF hand. The high -level control system will provide analog signals...AWARD NUMBER: W81XWH-16-1-0767 TITLE: Workflow Optimization for Tuning Prostheses with High Input Channel PRINCIPAL INVESTIGATOR: Daniel Merrill...Unlimited The views, opinions and/or findings contained in this report are those of the author(s) and should not be construed as an official Department

  13. Development of upper limb prostheses: current progress and areas for growth.

    PubMed

    González-Fernández, Marlís

    2014-06-01

    Upper extremity prosthetic technology has significantly changed in recent years. The devices available and those under development are more and more able to approximate the function of the lost limb; however, other challenges remain. This article provides a brief perspective on the most advanced upper limb prostheses available and the challenges present for continued development of the technology. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  14. SiC Protective Coating for Photovoltaic Retinal Prostheses

    PubMed Central

    Lei, Xin; Kane, Sheryl; Cogan, Stuart; Lorach, Henri; Galambos, Ludwig; Huie, Philip; Mathieson, Keith; Kamins, Theodore; Harris, James; Palanker, Daniel

    2016-01-01

    Objective To evaluate PECVD SiC as a protective coating for retinal prostheses and other implantable devices, and to study their failure mechanisms in vivo. Approach Retinal prostheses were implanted in rats subretinally for up to 1 year. Degradation of implants was characterized by optical and scanning electron microscopy. Dissolution rates of SiC, SiNx and thermal SiO2 were measured in accelerated soaking tests in saline at 87°C. Defects in SiC films were revealed and analyzed by selectively removing the materials underneath those defects. Main results At 87°C SiNx dissolved at 18.3±0.3nm/day, while SiO2 grown at high temperature (1000°C) dissolved at 1.04±0.08A/day. SiC films demonstrated the best stability, with no quantifiable change after 112 days. Defects in thin SiC films appeared primarily over complicated topography and rough surfaces. Significance SiC coatings demonstrating no erosion in accelerated aging test for 112 days at 87°C, equivalent to about 10 years in vivo, can offer effective protection of the implants. Photovoltaic retinal prostheses with PECVD SiC coatings exhibited effective protection from erosion during the 4-month follow-up in vivo. The optimal thickness of SiC layers is about 560nm, as defined by anti-reflective properties and by sufficient coverage to eliminate defects. PMID:27323882

  15. In vitro leakage susceptibility of tracheoesophageal shunt prostheses in the absence and presence of a biofilm.

    PubMed

    Oosterhof, Janine J H; van der Mei, Henny C; Busscher, Henk J; Free, Rolien H; Kaper, Hans J; van Weissenbruch, Ranny; Albers, Frans W J

    2005-04-01

    Although leakage through a tracheoesophageal shunt prosthesis is the main cause of prosthesis failure in a laryngectomy patient, this has never been the subject of in vitro evaluation. The aim of this study was to compare three commercially available voice prostheses by comparison of their in vitro leakage patterns, in absence or presence of a biofilm. To compare in vitro leakage patterns, a model comprised of an artificial throat equipped with a single prosthesis coupled to a water reservoir was developed. By varying the height of the water reservoir, different pressures on the voice prosthesis can be obtained. Both in absence and presence of a biofilm, the Blom Singer voice prosthesis demonstrated the lowest leakage, followed by Groningen Low Resistance. The Provox2 showed significantly the most leakage, however, in presence of a biofilm the leakage of the Provox2 significantly decreased. Regular airflow during biofilm formation significantly increased leakage through the Provox2. Out of 746 clinical replacements, Provox2 showed 76% and Groningen Low Resistance 57% replacements due to leakage. The model used in this study showed significant differences in leakage of the three types of voice prostheses used. Leakage occurred more readily through Provox2 than through Groningen Low Resistance and Blom Singer prostheses, which is in line with clinical observations and enforces the model. (c) 2005 Wiley Periodicals, Inc.

  16. Depigmented skin and phantom color measurements for realistic prostheses.

    PubMed

    Tanner, Paul; Leachman, Sancy; Boucher, Kenneth; Ozçelik, Tunçer Burak

    2014-02-01

    The purpose of this study was to test the hypothesis that regardless of human skin phototype, areas of depigmented skin, as seen in vitiligo, are optically indistinguishable among skin phototypes. The average of the depigmented skin measurements can be used to develop the base color of realistic prostheses. Data was analyzed from 20 of 32 recruited vitiligo study participants. Diffuse reflectance spectroscopy measurements were made from depigmented skin and adjacent pigmented skin, then compared with 66 pigmented polydimethylsiloxane phantoms to determine pigment concentrations in turbid media for making realistic facial prostheses. The Area Under spectral intensity Curve (AUC) was calculated for average spectroscopy measurements of pigmented sites in relation to skin phototype (P = 0.0505) and depigmented skin in relation to skin phototype (P = 0.59). No significant relationship exists between skin phototypes and depigmented skin spectroscopy measurements. The average of the depigmented skin measurements (AUC 19,129) was the closest match to phantom 6.4 (AUC 19,162). Areas of depigmented skin are visibly indistinguishable per skin phototype, yet spectrometry shows that depigmented skin measurements varied and were unrelated to skin phototype. Possible sources of optical variation of depigmented skin include age, body site, blood flow, quantity/quality of collagen, and other chromophores. The average of all depigmented skin measurements can be used to derive the pigment composition and concentration for realistic facial prostheses. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Preliminary study of acoustic analysis for evaluating speech-aid oral prostheses: Characteristic dips in octave spectrum for comparison of nasality.

    PubMed

    Chang, Yen-Liang; Hung, Chao-Ho; Chen, Po-Yueh; Chen, Wei-Chang; Hung, Shih-Han

    2015-10-01

    Acoustic analysis is often used in speech evaluation but seldom for the evaluation of oral prostheses designed for reconstruction of surgical defect. This study aimed to introduce the application of acoustic analysis for patients with velopharyngeal insufficiency (VPI) due to oral surgery and rehabilitated with oral speech-aid prostheses. The pre- and postprosthetic rehabilitation acoustic features of sustained vowel sounds from two patients with VPI were analyzed and compared with the acoustic analysis software Praat. There were significant differences in the octave spectrum of sustained vowel speech sound between the pre- and postprosthetic rehabilitation. Acoustic measurements of sustained vowels for patients before and after prosthetic treatment showed no significant differences for all parameters of fundamental frequency, jitter, shimmer, noise-to-harmonics ratio, formant frequency, F1 bandwidth, and band energy difference. The decrease in objective nasality perceptions correlated very well with the decrease in dips of the spectra for the male patient with a higher speech bulb height. Acoustic analysis may be a potential technique for evaluating the functions of oral speech-aid prostheses, which eliminates dysfunctions due to the surgical defect and contributes to a high percentage of intelligible speech. Octave spectrum analysis may also be a valuable tool for detecting changes in nasality characteristics of the voice during prosthetic treatment of VPI. Copyright © 2014. Published by Elsevier B.V.

  18. Colour stability of maxillofacial silicone elastomers: a review of the literature.

    PubMed

    Kulkarni, R S; Nagda, S J

    2014-09-01

    Colour degradation is a serious limitation of maxillofacial silicone elastomers and most silicone facial prostheses have to be remade within 1 year due to colour deterioration. A comprehensive review of the literature was completed using MEDLINE and PubMed Library databases. This was supplemented with a manual search of selected journals and textbooks. English language articles published in peer-reviewed journals from 1966 to January 2012 in which colour stability of silicone elastomers was evaluated using standard research protocols were included. In all, 127 articles were identified and 23 met the inclusion criteria. Current literature reveals that average colour stability of maxillofacial silicone prostheses is 6-12 months, and inherent unstable nature of silicones is responsible for the color degradation. Opacifiers, oil pigments and inorganic colourants may have a protective effect on colour stability of prostheses. Organic colourants, ultraviolet (UV) light, cleansing solutions, dust and aging can adversely affect colour stability of silicone prostheses. A direct comparison between studies has not been possible, because of the differences in experimental set-up such as materials tested, colourants used, or method of aging. There appears to be a need for a standardised test protocol for colour stability of maxillofacial materials. Colour degradation limits the useful lifespan of maxillofacial silicones. Improvements in colour stability is possible with the use of certain nano opacifiers, UV absorbers, photoprotective agents, and use of inorganic pigments and metal oxides.

  19. Survival rates of teeth, implants, and double crown-retained removable dental prostheses: a systematic literature review.

    PubMed

    Koller, Beatrice; Att, Wael; Strub, Jorg-Rudolf

    2011-01-01

    The aim of this systematic literature review was to investigate the survival rates of teeth, implants, and double crown-retained removable dental prostheses (RDPs). A systematic review of the literature published from January 1973 through May 2010 was conducted using electronic databases and hand-searching to assess the clinical outcomes of teeth, implants, and double crown-retained RDPs. This review yielded 512 articles, which were narrowed down to 11. The included studies demonstrated tooth survival rates between 60.6% and 95.3% after an observation period of 4 to 10 years. The survival rates of RDPs supported by teeth ranged between 90.0% and 95.1% after 4 and 5.3 years, respectively. The survival rates of implants supporting prostheses in the mandible were between 97% and 100% after an observation period between 3 and 10.4 years. The survival rates of implant-retained RDPs in the mandible ranged between 95% and 100% after 9 and 10.4 years. Teeth and implants supporting prostheses in the maxilla, as well as the RDPs themselves, demonstrated a survival rate of 100% after 3.2 years. The current literature does not provide sufficient information regarding the long-term outcome of double crown-retained RDPs. Further studies based on a higher level of evidence are needed to validate the outcomes of this treatment modality.

  20. Alterations in walking knee joint stiffness in individuals with knee osteoarthritis and self-reported knee instability.

    PubMed

    Gustafson, Jonathan A; Gorman, Shannon; Fitzgerald, G Kelley; Farrokhi, Shawn

    2016-01-01

    Increased walking knee joint stiffness has been reported in patients with knee osteoarthritis (OA) as a compensatory strategy to improve knee joint stability. However, presence of episodic self-reported knee instability in a large subgroup of patients with knee OA may be a sign of inadequate walking knee joint stiffness. The objective of this work was to evaluate the differences in walking knee joint stiffness in patients with knee OA with and without self-reported instability and examine the relationship between walking knee joint stiffness with quadriceps strength, knee joint laxity, and varus knee malalignment. Overground biomechanical data at a self-selected gait velocity was collected for 35 individuals with knee OA without self-reported instability (stable group) and 17 individuals with knee OA and episodic self-reported instability (unstable group). Knee joint stiffness was calculated during the weight-acceptance phase of gait as the change in the external knee joint moment divided by the change in the knee flexion angle. The unstable group walked with lower knee joint stiffness (p=0.01), mainly due to smaller heel-contact knee flexion angles (p<0.01) and greater knee flexion excursions (p<0.01) compared to their knee stable counterparts. No significant relationships were observed between walking knee joint stiffness and quadriceps strength, knee joint laxity or varus knee malalignment. Reduced walking knee joint stiffness appears to be associated with episodic knee instability and independent of quadriceps muscle weakness, knee joint laxity or varus malalignment. Further investigations of the temporal relationship between self-reported knee joint instability and walking knee joint stiffness are warranted. Copyright © 2015 Elsevier B.V. All rights reserved.

Top