Shin, Sung Joon; Lee, Ji-Ho; Lee, Jae Hyup
2017-07-01
A prospective, within-patient, left-right comparative study. To evaluate the efficacy of hydroxyapatite (HA) stick augmentation method by comparing the insertional torque of the pedicle screw in osteoporotic and nonosteoporotic patients. Unsatisfactory clinical outcomes after spine surgery in osteoporotic patients are related to pedicle screw loosening or pull-outs. HA, as a bone graft extender, has a possibility to enhance the fixation strength at the bone-screw interface. From November 2009 to December 2010, among patients who required bilateral pedicle screw fixation for lumbar spine surgery, 22 patients were enrolled, who recieved unilateral HA stick augmentation and completed intraoperative insertional torque measurement of each pedicle screws. On the basis of preoperative evaluation of bone mineral density, patients with osteoporosis had 2 HA sticks inserted unilaterally, and 1 stick for patients without osteoporosis. Pedicle screw loosening and pull-outs were assessed using 12-month postoperative CT scans and follow-up radiographs. Clinical evaluation was done preoperatively and at 1 year postoperatively, based on Visual Analog Scale score, Oswestry Disability Index, and Short Form-36 Health Survey. Regardless of bone mineral density, the average torque value of all pedicle screws with HA stick insertion (HA stick inserted group) was significantly higher than that of all pedicle screws without HA insertion (control group) (P<0.0001). Same results were seen in the HA stick inserted subgroups and the control subgroups within both of the osteoporosis group (P=0.009) and the nonosteoporosis group (P=0.0004). There was no statistically significant difference of the rate of pedicle screw loosening in between the HA stick inserted group and the control group. Clinical evaluation also showed no statistically significant difference in between patients with loosening and those without. The enhancement of initial pedicle screw fixation strength in osteoporotic patients can be achieved by HA stick augmentation.
Yi, Seong; Rim, Dae-Cheol; Park, Seoung Woo; Murovic, Judith A; Lim, Jesse; Park, Jon
2015-06-01
In vertebrae with low bone mineral densities pull out strength is often poor, thus various substances have been used to fill screw holes before screw placement for corrective spine surgery. We performed biomechanical cadaveric studies to compare nonaugmented pedicle screws versus hydroxyapatite, calcium phosphate, or polymethylmethacrylate augmented pedicle screws for screw tightening torques and pull out strengths in spine procedures requiring bone screw insertion. Seven human cadaveric T10-L1 spines with 28 vertebral bodies were examined by x-ray to exclude bony abnormalities. Dual-energy x-ray absorptiometry scans evaluated bone mineral densities. Twenty of 28 vertebrae underwent ipsilateral fluoroscopic placement of 6-mm holes augmented with hydroxyapatite, calcium phosphate, or polymethylmethacrylate, followed by transpedicular screw placements. Controls were pedicle screw placements in the contralateral hemivertebrae without augmentation. All groups were evaluated for axial pull out strength using a biomechanical loading frame. Mean pedicle screw axial pull out strength compared with controls increased by 12.5% in hydroxyapatite augmented hemivertebrae (P = 0.600) and by 14.9% in calcium phosphate augmented hemivertebrae (P = 0.234), but the increase was not significant for either method. Pull out strength of polymethylmethacrylate versus hydroxyapatite augmented pedicle screws was 60.8% higher (P = 0.028). Hydroxyapatite and calcium phosphate augmentation in osteoporotic vertebrae showed a trend toward increased pedicle screw pull out strength versus controls. Pedicle screw pull out force of polymethylmethacrylate in the insertion stage was higher than that of hydroxyapatite. However, hydroxyapatite is likely a better clinical alternative to polymethylmethacrylate, as hydroxyapatite augmentation, unlike polymethylmethacrylate augmentation, stimulates bone growth and can be revised. Copyright © 2015 Elsevier Inc. All rights reserved.
Bostelmann, Richard; Keiler, Alexander; Steiger, Hans Jakob; Scholz, Armin; Cornelius, Jan Frederick; Schmoelz, Werner
2017-01-01
Augmentation of pedicle screws is recommended in selected indications (for instance: osteoporosis). Generally, there are two techniques for pedicle screw augmentation: inserting the screw in the non cured cement and in situ-augmentation with cannulated fenestrated screws, which can be applied percutaneously. Most of the published studies used an axial pull out test for evaluation of the pedicle screw anchorage. However, the loading and the failure mode of pullout tests do not simulate the cranio-caudal in vivo loading and failure mechanism of pedicle screws. The purpose of the present study was to assess the fixation effects of different augmentation techniques (including percutaneous cement application) and to investigate pedicle screw loosening under physiological cyclic cranio-caudal loading. Each of the two test groups consisted of 15 vertebral bodies (L1-L5, three of each level per group). Mean age was 84.3 years (SD 7.8) for group 1 and 77.0 years (SD 7.00) for group 2. Mean bone mineral density was 53.3 mg/cm 3 (SD 14.1) for group 1 and 53.2 mg/cm 3 (SD 4.3) for group 2. 1.5 ml high viscosity PMMA bone cement was used for all augmentation techniques. For test group 1, pedicles on the right side of the vertebrae were instrumented with solid pedicle screws in standard fashion without augmentation and served as control group. Left pedicles were instrumented with cannulated screws (Viper cannulated, DePuy Spine) and augmented. For test group 2 pedicles on the left side of the vertebrae were instrumented with cannulated fenestrated screws and in situ augmented. On the right side solid pedicle screws were augmented with cement first technique. Each screw was subjected to a cranio-caudal cyclic load starting at 20-50 N with increasing upper load magnitude of 0.1 N per cycle (1 Hz) for a maximum of 5000 cycles or until total failure. Stress X-rays were taken after cyclic loading to evaluate screw loosening. Test group 1 showed a significant higher number of load cycles until failure for augmented screws compared to the control (4030 cycles, SD 827.8 vs. 1893.3 cycles, SD 1032.1; p < 0.001). Stress X-rays revealed significant less screw toggling for the augmented screws (5.2°, SD 5.4 vs. 16.1°, SD 5.9; p < 0.001). Test group 2 showed 3653.3 (SD 934) and 3723.3 (SD 560.6) load cycles until failure for in situ and cement first augmentation. Stress X-rays revealed a screw toggling of 5.1 (SD 1.9) and 6.6 (SD 4.6) degrees for in situ and cement first augmentation techniques (p > 0.05). Augmentation of pedicle screws in general significantly increased the number of load cycles and failure load comparing to the nonaugmented control group. For the augmentation technique (cement first, in situ augmented, percutaneously application) no effect could be exhibited on the failure of the pedicle screws. By the cranio-caudal cyclic loading failure of the pedicle screws occurred by screw cut through the superior endplate and the characteristic "windshield-wiper effect", typically observed in clinical practice, could be reproduced.
Kiyak, Gorkem; Balikci, Tevfik; Heydar, Ahmed Majid; Bezer, Murat
2018-02-01
Mechanical study. To compare the pullout strength of different screw designs and augmentation techniques in an osteoporotic bone model. Adequate bone screw pullout strength is a common problem among osteoporotic patients. Various screw designs and augmentation techniques have been developed to improve the biomechanical characteristics of the bone-screw interface. Polyurethane blocks were used to mimic human osteoporotic cancellous bone, and six different screw designs were tested. Five standard and expandable screws without augmentation, eight expandable screws with polymethylmethacrylate (PMMA) or calcium phosphate augmentation, and distal cannulated screws with PMMA and calcium phosphate augmentation were tested. Mechanical tests were performed on 10 unused new screws of each group. Screws with or without augmentation were inserted in a block that was held in a fixture frame, and a longitudinal extraction force was applied to the screw head at a loading rate of 5 mm/min. Maximum load was recorded in a load displacement curve. The peak pullout force of all tested screws with or without augmentation was significantly greater than that of the standard pedicle screw. The greatest pullout force was observed with 40-mm expandable pedicle screws with four fins and PMMA augmentation. Augmented distal cannulated screws did not have a greater peak pullout force than nonaugmented expandable screws. PMMA augmentation provided a greater peak pullout force than calcium phosphate augmentation. Expandable pedicle screws had greater peak pullout forces than standard pedicle screws and had the advantage of augmentation with either PMMA or calcium phosphate cement. Although calcium phosphate cement is biodegradable, osteoconductive, and nonexothermic, PMMA provided a significantly greater peak pullout force. PMMA-augmented expandable 40-mm four-fin pedicle screws had the greatest peak pullout force.
Shen, Xiaolong; Wang, Lei; Zhang, Hailong; Gu, Xin; Gu, Guangfei; He, Shisheng
2016-02-01
A prospective randomized study was conducted. The purpose of this study was to assess the radiographic outcomes of one-level minimally invasive transforaminal lumbar interbody fusion (MI-TLIF) with unilateral pedicle screw instrumentation for degenerative lumbar spine disease. MI-TLIF has become an increasingly popular method of lumbar arthrodesis. Recent technological advances in spinal instrumentation have culminated in the development of MI-TLIF with unilateral pedicle screw fixation. However, there are few published studies on radiographic outcomes of the MI-TLIF with unilateral pedicle screw fixation. A total of 65 patients with one-level degenerative lumbar spine disease were enrolled in this study. Patients were randomized into the unilateral or bilateral fixation group based on a computer-generated number list. Thirty-one patients (17 men and 14 women; average age, 57.3 y) were randomized to the unilateral group (group A) and 34 patients (16 men and 18 women; average age, 58.9 y) to the bilateral group (group B). All patients underwent minimally invasive decompression, interbody fusion, and pedicle screw fixation with the assistance of microscopic tubular retractor system (METRx-MD) and Sextant system. All patients were asked to follow-up at 3, 6, and thereafter once every 6 months after surgery. The visual analog scale (VAS), Oswestry disability index (ODI), and modified Prolo (mProlo) scores were obtained for all patients 24 hours before the operation and at each follow-up visit. The whole lumbar lordosis (WL), the segmental lordosis (SL), fusion level disk space angle, lumbar scoliosis angle, and segmental scoliosis angle were determined before and after surgery on standard x-rays. The disk height index (DI) and the lumber curvature index (LI) were also evaluated. The mean follow-up was 26.6 months, with a range of 18-36 months. All patients showed evidence of fusion at 12 months postoperatively. Statistically, there was no significant difference between the 2 groups in terms of demographic data. The average postoperative VAS, ODI, and mProlo scores improved significantly in each group. No significant differences were found between the 2 groups in relation to VAS, ODI, and mProlo scores at each follow-up time point. There were no significant differences between the 2 groups in relation to WL, SL, disk space angle, lumbar scoliosis angle, segmental scoliosis angle, DI, and LI. There was also no difference between postoperative different follow-up visits in terms of these radiographic parameters in both groups. There was a positive linear correlation between the LI and WL in both groups. One-level unilateral pedicle screw instrumented MI-TLIF provided similar radiologic and clinical outcomes to bilateral pedicle screw instrumented MI-TLIF. This study showed that MIS-TLIF with unilateral pedicle screw fixation would be sufficient in the management of preoperatively stable patients with lumbar degenerative disease.
Guo, Zhiping; Chen, Wei; Su, Yanling; Yuan, Junhui; Zhang, Yingze
2013-11-01
The vertebral pedicle injuries are clinically common. However, the isolated vertebral pedicle fracture with intact vertebral bodies is a rare lesion. We reported a case of a 66-year-old man who experienced a pedicle fracture after a back massage. The patient sustained osteoporosis, long-existing low back pain and nerve compression symptoms without antecedent major trauma. Imaging findings demonstrated an isolated unilateral L5 vertebral pedicle fracture with intact vertebral bodies, spinal canal stenosis at the L4-5 levels, bulging annulus fibrosus at the L4-S1 levels, bilateral spondylolysis and an L5/S1 spondylolisthesis. The patient underwent L4-S1 decompressive laminectomy, L5/S1 discectomy and neurolysis, and reduction and fixation of the L5 vertebral pedicle fracture and L5/S1 spondylolisthesis using the pedicle nail system. At follow-ups, the patient showed good recovery without pain or numbness in the low back and bilateral lower extremities. This study raises the awareness of a complication of alternative medicine and the possibility of a pedicle fracture caused by a low-energy trauma.
Results of cement augmentation and curettage in aneurysmal bone cyst of spine
Basu, Saumyajit; Patel, Dharmesh R; Dhakal, Gaurav; Sarangi, T
2016-01-01
Aneurysmal bone cyst (ABC) is a vascular tumor of the spine. Management of spinal ABC still remains controversial because of its location, vascular nature and incidence of recurrence. In this manuscript, we hereby describe two cases of ABC spine treated by curettage, vertebral cement augmentation for control of bleeding and internal stabilization with two years followup. To the best of our knowledge, this is the first case report in the literature describing the role of cement augmentation in spinal ABC in controlling vascular bleeding in curettage of ABC of spine. Case 1: A 22 year old male patient presented with chronic back pain. On radiological investigation, there were multiple, osteolytic septite lesions at L3 vertebral body without neural compression or instability. Percutaneous transpedicular biopsy of L3 from involved pedicle was done. This was followed by cement augmentation through the uninvolved pedicle. Next, transpedicular complete curettage was done through involved pedicle. Case 2: A 15-year-old female presented with nonradiating back pain and progressive myelopathy. On radiological investigation, there was an osteolytic lesion at D9. At surgery, decompression, pedicle screw-rod fixation and posterolateral fusion from D7 to D11 was done. At D9 level, through normal pedicle cement augmentation was added to provide anterior column support and to control the expected bleeding following curettage. Transpedicular complete curettage was done through the involved pedicle with controlled bleeding at the surgical field. Cement augmentation was providing controlled bleeding at surgical field during curettage, internal stabilization and control of pain. On 2 years followup, pain was relieved and there was a stable spinal segment with well filled cement without any sign of recurrence in computed tomography scan. In selected cases of spinal ABC with single vertebral, single pedicle involvement; cement augmentation of vertebra through normal pedicle has an important role in surgery aimed for curettage of vertebra. PMID:26955184
Fan, Haitao T; Zhang, Renjie J; Shen, Cailiang L; Dong, Fulong L; Li, Yong; Song, Peiwen W; Gong, Chen; Wang, Yijin J
2016-03-01
The biomechanics of pedicle screw fixation combined with trajectory cement augmentation with various filling volumes were measured by pull-out, periodic antibending, and compression fatigue tests. To investigate the biomechanical properties of the pedicle screw fixation combined with trajectory bone cement (polymethylmethacrylate) augmentation in osteoporotic vertebrae and to explore the optimum filling volume of the bone cement. Pedicle screw fixation is considered to be the most effective posterior fixation method. The decrease of the bone mineral density apparently increases the fixation failure risk caused by screw loosening and displacement. Trajectory bone cement augmentation has been confirmed to be an effective method to increase the bone intensity and could markedly increase the stability of the fixation interface. Sixteen elderly cadaveric 1-5 lumbar vertebral specimens were diagnosed with osteoporosis. The left and right vertebral pedicles were alternatively randomized for treatment in all groups, with the contralateral pedicles as control. The study groups included: group A (pedicle screw fixation with full trajectory bone cement augmentation), group B (75% filling), group C (50% filling), and group D (25% filling). Finally, the bone cement leakage and dispersion were assessed and the mechanical testing was conducted. The bone cement was well dispersed around the pedicle screw. The augmented bone intensity, pull-out strength, periodic loading times, and compression fatigue performance were markedly higher than those of the control groups. With the increase in trajectory bone cement, the leakage was also increased (P<0.05). The pull-out strength of the pedicle screw was increased with an increase in bone mineral density and trajectory bone cement. It peaked at 75% filling, with the largest power consumption. The optimal filling volume of the bone cement was 75% of the trajectory volume (about 1.03 mL). The use of excessive bone cement did not increase the fixation intensity but increased the risk of leakage.
Pedicle screw anchorage of carbon fiber-reinforced PEEK screws under cyclic loading.
Lindtner, Richard A; Schmid, Rene; Nydegger, Thomas; Konschake, Marko; Schmoelz, Werner
2018-03-01
Pedicle screw loosening is a common and significant complication after posterior spinal instrumentation, particularly in osteoporosis. Radiolucent carbon fiber-reinforced polyetheretherketone (CF/PEEK) pedicle screws have been developed recently to overcome drawbacks of conventional metallic screws, such as metal-induced imaging artifacts and interference with postoperative radiotherapy. Beyond radiolucency, CF/PEEK may also be advantageous over standard titanium in terms of pedicle screw loosening due to its unique material properties. However, screw anchorage and loosening of CF/PEEK pedicle screws have not been evaluated yet. The aim of this biomechanical study therefore was to evaluate whether the use of this alternative nonmetallic pedicle screw material affects screw loosening. The hypotheses tested were that (1) nonmetallic CF/PEEK pedicle screws resist an equal or higher number of load cycles until loosening than standard titanium screws and that (2) PMMA cement augmentation further increases the number of load cycles until loosening of CF/PEEK screws. In the first part of the study, left and right pedicles of ten cadaveric lumbar vertebrae (BMD 70.8 mg/cm 3 ± 14.5) were randomly instrumented with either CF/PEEK or standard titanium pedicle screws. In the second part, left and right pedicles of ten vertebrae (BMD 56.3 mg/cm 3 ± 15.8) were randomly instrumented with either PMMA-augmented or nonaugmented CF/PEEK pedicle screws. Each pedicle screw was subjected to cyclic cranio-caudal loading (initial load ranging from - 50 N to + 50 N) with stepwise increasing compressive loads (5 N every 100 cycles) until loosening or a maximum of 10,000 cycles. Angular screw motion ("screw toggling") within the vertebra was measured with a 3D motion analysis system every 100 cycles and by stress fluoroscopy every 500 cycles. The nonmetallic CF/PEEK pedicle screws resisted a similar number of load cycles until loosening as the contralateral standard titanium screws (3701 ± 1228 vs. 3751 ± 1614 load cycles, p = 0.89). PMMA cement augmentation of CF/PEEK pedicle screws furthermore significantly increased the mean number of load cycles until loosening by 1.63-fold (5100 ± 1933 in augmented vs. 3130 ± 2132 in nonaugmented CF/PEEK screws, p = 0.015). In addition, angular screw motion assessed by stress fluoroscopy was significantly smaller in augmented than in nonaugmented CF/PEEK screws before as well as after failure. Using nonmetallic CF/PEEK instead of standard titanium as pedicle screw material did not affect screw loosening in the chosen test setup, whereas cement augmentation enhanced screw anchorage of CF/PEEK screws. While comparable to titanium screws in terms of screw loosening, radiolucent CF/PEEK pedicle screws offer the significant advantage of not interfering with postoperative imaging and radiotherapy. These slides can be retrieved under Electronic Supplementary Material.
Karius, T; Deborre, C; Wirtz, D C; Burger, C; Prescher, A; Fölsch, A; Kabir, K; Pflugmacher, R; Goost, H
2017-01-01
PMMA-augmentation of pedicle screws strengthens the bone-screw-interface reducing cut-out risk. Injection of fluid cement bears a higher risk of extravasation, with difficulty of application because of inconsistent viscosity and limited injection time. To test a new method of cement augmentation of pedicle screws using radiofrequency-activated PMMA, which is suspected to be easier to apply and have less extravasations. Twenty-seven fresh-frozen human cadaver lumbar spines were divided into 18 osteoporotic (BMD ≤ 0.8 g/cm2) and 9 non-osteoporotic (BMD > 0.8 g/cm2) vertebral bodies. Bipedicular cannulated pedicle screws were implanted into the vertebral bodies; right screws were augmented with ultra-high viscosity PMMA, whereas un-cemented left pedicle screws served as negative controls. Cement distribution was controlled with fluoroscopy and CT scans. Axial pullout forces of the screws were measured with a material testing machine, and results were analyzed statistically. Fluoroscopy and CT scans showed that in all cases an adequately big cement depot with homogenous form and no signs of extravasation was injected. Pullout forces showed significant differences (p < 0.001) between the augmented and non-augmented pedicle screws for bone densities below 0.8 g/cm2 (661.9 N ± 439) and over 0.8 g/cm2 (744.9 N ± 415). Pullout-forces were significantly increased in osteoporotic as well as in non-osteoporotic vertebral bodies without a significant difference between these groups using this standardized, simple procedure with increased control and less complications like extravasation.
Hickerson, Lindsay E; Owen, John R; Wayne, Jennifer S; Tuten, H Robert
2013-01-01
Biomechanical pullout study using calcium triglyceride (CTG) and polymethylmethacrylate (PMMA) for screw augmentation. Compare the biomechanical performance of CTG augmentation versus the gold standard, PMMA, in primary and revision models, using a pedicle screw pullout model. CTG is a novel form of bone augmentation with several reported biocompatible properties compared with PMMA. PMMA is the standard of care for pedicle screw augmentation in osteoporotic spine. Blocks of closed-cell rigid polyurethane foam of uniform density, representing subcortical layer in osteoporotic pedicle, were prepared according to ASTM standards. After the components of PMMA (n = 11) and CTG (n = 11) were individually mixed in a standardized fashion, 0.2 ml was injected from deep to superficial along a predrilled pilot hole followed by immediate insertion of the pedicle screw. An unaugmented group (n = 10) was also prepared. Blocks cured for 24 hrs, and screws were pulled out at a rate of 5 mm/min on materials testing equipment. For the revision model, the unaugmented group, after screw pullout, was augmented with 0.8 ml of PMMA (n = 5) or CTG (n = 5) as detailed above and screw pullout performed similarly. The mean pullout strengths (SD) for the intact models were as follows: unaugmented, 976.6 N (94.2 N); PMMA, 1,218.1 N (66.8 N); and CTG, 1,841.6 N (57.4 N). A one-way analysis of variance indicated a significant difference among the primary models (p < .0001). For the revision models, the pullout strength for PMMA was 1,939.2 N (108.9 N) and for CTG, 2,513.0 N (149.1 N), which were statistically different from each other (p < .0003). Stiffness of the constructs was increased with both PMMA and CTG augmentation over no augmentation (p < .0001) although no significant difference in stiffness was detected between the 2 forms of augmentation. We conclude that CTG augmentation of pedicle screws resulted in significantly higher axial pullout strength in primary (p < .0001) and revision (p < .0003) models compared with PMMA. Copyright © 2013 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.
Spiotta, Alejandro M; James, Robert F; Lowe, Stephen R; Vargas, Jan; Turk, Aquilla S; Chaudry, M Imran; Bhalla, Tarun; Janjua, Rashid M; Delaney, John J; Quintero-Wolfe, Stacey; Turner, Raymond D
2015-10-01
Conventional Onyx embolization of cerebral arteriovenous malformations (AVMs) requires lengthy procedure and fluoroscopy times to form an adequate 'proximal plug' which allows forward nidal penetration while preventing reflux and non-targeted embolization. We review our experience with balloon-augmented Onyx embolization of cerebral AVMs using a dual-lumen balloon catheter technique designed to minimize these challenges. Retrospectively acquired data for all balloon-augmented cerebral AVM embolizations performed between 2011 and 2014 were obtained from four tertiary care centers. For each procedure, at least one Scepter C balloon catheter was advanced into the AVM arterial pedicle of interest and Onyx embolization was performed through the inner lumen after balloon inflation via the outer lumen. Twenty patients underwent embolization with the balloon-augmented technique over 24 discreet treatment episodes. There were 37 total arterial pedicles embolized with the balloon-augmented technique, a mean of 1.9 per patient (range 1-5). The treated AVMs were heterogeneous in their location and size (mean 3.3±1.6 cm). Mean fluoroscopy time for each procedure was 48±26 min (28 min per embolized pedicle). Two Scepter C balloon catheter-related complications (8.3% of embolization sessions, 5.4% of pedicles embolized) were observed: an intraprocedural rupture of a feeding pedicle and fracture and retention of a catheter fragment. This multicenter experience represents the largest reported series of balloon-augmented Onyx embolization of cerebral AVMs. The technique appears safe and effective in the treatment of AVMs, allowing more efficient and controlled injection of Onyx with a decreased risk of reflux and decreased fluoroscopy times. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Gibby, Jacob T; Swenson, Samuel A; Cvetko, Steve; Rao, Raj; Javan, Ramin
2018-06-22
Augmented reality has potential to enhance surgical navigation and visualization. We determined whether head-mounted display augmented reality (HMD-AR) with superimposed computed tomography (CT) data could allow the wearer to percutaneously guide pedicle screw placement in an opaque lumbar model with no real-time fluoroscopic guidance. CT imaging was obtained of a phantom composed of L1-L3 Sawbones vertebrae in opaque silicone. Preprocedural planning was performed by creating virtual trajectories of appropriate angle and depth for ideal approach into the pedicle, and these data were integrated into the Microsoft HoloLens using the Novarad OpenSight application allowing the user to view the virtual trajectory guides and CT images superimposed on the phantom in two and three dimensions. Spinal needles were inserted following the virtual trajectories to the point of contact with bone. Repeat CT revealed actual needle trajectory, allowing comparison with the ideal preprocedural paths. Registration of AR to phantom showed a roughly circular deviation with maximum average radius of 2.5 mm. Users took an average of 200 s to place a needle. Extrapolation of needle trajectory into the pedicle showed that of 36 needles placed, 35 (97%) would have remained within the pedicles. Needles placed approximated a mean distance of 4.69 mm in the mediolateral direction and 4.48 mm in the craniocaudal direction from pedicle bone edge. To our knowledge, this is the first peer-reviewed report and evaluation of HMD-AR with superimposed 3D guidance utilizing CT for spinal pedicle guide placement for the purpose of cannulation without the use of fluoroscopy.
Liu, Xiaoyang; Li, Guangrun; Wang, Jiefeng; Zhang, Heqing
2015-11-25
BACKGROUND The choice for instrumentation with minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) in treatment of degenerative lumbar disorders (DLD) remains controversial. The goal of this study was to investigate clinical outcomes in consecutive patients with multi-segment DLD treated with unilateral pedicle screw (UPS) vs. bilateral pedicle screw (BPS) instrumented TLIF. MATERIAL AND METHODS Eighty-four consecutive patients who had multi-level MIS-TLIF were retrospectively reviewed. All data were collected to compare the clinical outcomes between the 2 groups. RESULTS Both groups showed similar clinical function scores in VAS and ODI. The two groups differed significantly in operative time (P<0.001), blood loss (P<0.001), and fusion rate (P=0.043), respectively. CONCLUSIONS This study demonstrated similar clinical outcomes between UPS fixation and BPS procedure after MIS-TLIF for multi-level DLD. Moreover, UPS technique was superior in operative time and blood loss, but represented lower fusion rate than the BPS construct did.
Gologorsky, Yakov; Skovrlj, Branko; Steinberger, Jeremy; Moore, Max; Arginteanu, Marc; Moore, Frank; Steinberger, Alfred
2014-10-01
Transforaminal lumbar interbody fusion (TLIF) with segmental pedicular instrumentation is a well established procedure used to treat lumbar spondylosis with or without spondylolisthesis. Available biomechanical and clinical studies that compared unilateral and bilateral constructs have produced conflicting data regarding patient outcomes and hardware complications. A prospective cohort study was undertaken by a group of neurosurgeons. They prospectively enrolled 80 patients into either bilateral or unilateral pedicle screw instrumentation groups (40 patients/group). Demographic data collected for each group included sex, age, body mass index, tobacco use, and Workers' Compensation/litigation status. Operative data included segments operated on, number of levels involved, estimated blood loss, length of hospital stay, and perioperative complications. Long-term outcomes (hardware malfunction, wound dehiscence, and pseudarthrosis) were recorded. For all patients, preoperative baseline and 6-month postoperative scores for Medical Outcomes 36-Item Short Form Health Survey (SF-36) outcomes were recorded. Patient follow-up times ranged from 37 to 63 months (mean 52 months). No patients were lost to follow-up. The patients who underwent unilateral pedicle screw instrumentation (unilateral cohort) were slightly younger than those who underwent bilateral pedicle screw instrumentation (bilateral cohort) (mean age 42 vs. 47 years, respectively; p = 0.02). No other significant differences were detected between cohorts with regard to demographic data, mean number of lumbar levels operated on, or distribution of the levels operated on. Estimated blood loss was higher for patients in the bilateral cohort, but length of stay was similar for patients in both cohorts. The incidence of pseudarthrosis was significantly higher among patients in the unilateral cohort (7 patients [17.5%]) than among those in the bilateral cohort (1 patient [2.5%]) (p = 0.02). Wound dehiscence occurred for 1 patient in the unilateral cohort. Reoperation was offered to 8 patients in the unilateral cohort and 1 patient in the bilateral cohort (p = 0.03). The physical component scores of the Medical Outcomes SF-36 outcomes improved significantly for all patients (p < 0.001). Transforaminal lumbar interbody fusion with either unilateral or bilateral segmental pedicular instrumentation is an effective treatment for lumbar spondylosis. Because patients with unilateral constructs were 7 times more likely to experience pseudarthrosis and require reoperation, TLIF with bilateral constructs might be the biomechanically superior technique.
Korovessis, Panagiotis; Vardakastanis, Konstantinos; Repantis, Thomas; Vitsas, Vasilios
2014-04-01
The aim of this clinical study was to report on the efficacy in reduction and safety in PMMA leakage of a novel vertebral augmentation technique with PEEK and PMMA, together with pedicle screws in the treatment of fresh vertebral fractures in young adults. Twenty consecutive young adults aged 45 ± 11 years with fresh burst A3/AO or severely compressed A2/AO fractures underwent via a less invasive posterior approach one-staged reduction with a novel augmentation implant and PMMA plus 3-vertebrae pedicle screw fixation and fusion. Radiologic parameters as segmental kyphosis (SKA), anterior (AVBHr) and posterior vertebral body height ratio (PVBHr), spinal canal encroachment (SCE), cement leakage and functional parameters as VAS, SF-36 were measured pre- and post-operatively. Hybrid construct restored AVBHr (P < 0.000), PVBHr (P = 0.02), SKA (P = 0.015), SCE (P = 0.002) without loss of correction at an average follow-up of 17 months. PMMA leakage occurred in 3 patients (3 vertebrae) either anteriorly to the fractured vertebral body or to the adjacent disc, but in no case to the spinal canal. Two pedicle screws were malpositioned (one medially, one laterally to the pedicle at the fracture level) without neurologic sequelae. Solid posterolateral spinal fusion occurred 8-10 months post-operatively. Pre-operative VAS and SF-36 scores improved post-operatively significantly. This study showed that this novel vertebral augmentation technique using PEEK implant and PMMA reduces and stabilizes via less invasive technique A2 and A3 vertebral fractures without loss of correction and leakage to the spinal canal.
A finite element investigation of upper cervical instrumentation.
Puttlitz, C M; Goel, V K; Traynelis, V C; Clark, C R
2001-11-15
The finite element technique was used to predict changes in biomechanics that accompany the application of a novel instrumentation system designed for use in the upper cervical spine. To determine alterations in joint loading, kinematics, and instrumentation stresses in the craniovertebral junction after application of a novel instrumentation system. Specifically, this design was used to assess the changes in these parameters brought about by two different cervical anchor types: C2 pedicle versus C2-C1 transarticular screws, and unilateral versus bilateral instrumentation. Arthrodesis procedures can be difficult to obtain in the highly mobile craniovertebral junction. Solid fusion is most likely achieved when motion is eliminated. Biomechanical studies have shown that C1-C2 transarticular screws provide good stability in craniovertebral constructs; however, implantation of these screws is accompanied by risk of vertebral artery injury. A novel instrumentation system that can be used with transarticular screws or with C2 pedicle screws has been developed. This design also allows for unilateral or bilateral implantation. However, the authors are unaware of any reports to date on the changes in joint loading or instrumentation stresses that are associated with the choice of C2 anchor or unilateral/bilateral use. A ligamentous, nonlinear, sliding contact, three-dimensional finite element model of the C0-C1-C2 complex and a novel instrumentation system was developed. Validation of the model has been previously reported. Finite element models representing combinations of cervical anchor type (C1-C2 transarticular screws vs. C2 pedicle screws) and unilateral versus bilateral instrumentation were evaluated. All models were subjected to compression with pure moments in either flexion, extension, or lateral bending. Kinematic reductions with respect to the intact (uninjured and without instrumentation) case caused by instrumentation use were reported. Changes in loading profiles through the right and left C0-C1 and C1-C2 facets, transverse ligament-dens, and dens-anterior ring of C1 articulations were calculated by the finite element model. Maximum von Mises stresses within the instrumentation were predicted for each model variant and loading scenario. Bilateral instrumentation provided greater motion reductions than the unilateral instrumentation. When used bilaterally, C2 pedicle screws approximate the kinematic reductions and instrumentation stresses (except in lateral bending) that are seen with C1-C2 transarticular screws. The finite element model predicted that the maximum stress was always in the region in which the plate transformed into the rod. To the best of the authors' knowledge, this is the first report of predicting changes in loading in the upper cervical spine caused by instrumentation. The most significant conclusion that can be drawn from the finite element model predictions is that C2 pedicle screw fixation provides the same relative stability and instrumentation stresses as C1-C2 transarticular screw use. C2 pedicle screws can be a good alternative to C2-C1 transarticular screws when bilateral instrumentation is applied.
Elmi-Terander, Adrian; Skulason, Halldor; Söderman, Michael; Racadio, John; Homan, Robert; Babic, Drazenko; van der Vaart, Nijs; Nachabe, Rami
2016-11-01
A cadaveric laboratory study. The aim of this study was to assess the feasibility and accuracy of thoracic pedicle screw placement using augmented reality surgical navigation (ARSN). Recent advances in spinal navigation have shown improved accuracy in lumbosacral pedicle screw placement but limited benefits in the thoracic spine. 3D intraoperative imaging and instrument navigation may allow improved accuracy in pedicle screw placement, without the use of x-ray fluoroscopy, and thus opens the route to image-guided minimally invasive therapy in the thoracic spine. ARSN encompasses a surgical table, a motorized flat detector C-arm with intraoperative 2D/3D capabilities, integrated optical cameras for augmented reality navigation, and noninvasive patient motion tracking. Two neurosurgeons placed 94 pedicle screws in the thoracic spine of four cadavers using ARSN on one side of the spine (47 screws) and free-hand technique on the contralateral side. X-ray fluoroscopy was not used for either technique. Four independent reviewers assessed the postoperative scans, using the Gertzbein grading. Morphometric measurements of the pedicles axial and sagittal widths and angles, as well as the vertebrae axial and sagittal rotations were performed to identify risk factors for breaches. ARSN was feasible and superior to free-hand technique with respect to overall accuracy (85% vs. 64%, P < 0.05), specifically significant increases of perfectly placed screws (51% vs. 30%, P < 0.05) and reductions in breaches beyond 4 mm (2% vs. 25%, P < 0.05). All morphometric dimensions, except for vertebral body axial rotation, were risk factors for larger breaches when performed with the free-hand method. ARSN without fluoroscopy was feasible and demonstrated higher accuracy than free-hand technique for thoracic pedicle screw placement. N/A.
Yang, Mingjie; Sun, Guixin; Guo, Song; Zeng, Cheng; Yan, Meijun; Han, Yingchao; Xia, Dongdong; Zhang, Jingjie; Li, Xinhua; Xiang, Yang; Pan, Jie; Li, Lijun; Tan, Jun
2017-01-01
Finite-element method was used to evaluate biomechanics stability of extraforaminal lumbar interbody fusion (ELIF) under different internal fixation. The L3-L5 level finite-element model was established to simulate decompression and internal fixation at L4-L5 segment. The intact finite model was treated in accordance with the different internal fixation. The treatment groups were exerted 400 N load and 6 N·m additional force from motion to calculate the angular displacement of L4-L5. The ROMs were smaller in all internal fixation groups than those in the intact model. Furthermore, the ROMs were smaller in ELIF + UPS group than in TLIF + UPS group under all operating conditions, especially left lateral flexion and right rotation. The ROMs were higher in ELIF + UPS group than in TLIF + BPS group. The ROMs of ELIF + UPS + TLFS group were much smaller than those in ELIF + UPS group, and as compared with TLIF + BPS group, there was no significant difference in the range of experimental loading. The biomechanical stability of ELIF with unilateral pedicle screw fixation is superior to that of TLIF with unilateral pedicle screw fixation but lower than that of TLIF with bilateral pedicle screws fixation. The stability of ELIF with unilateral fixation can be further improved by supplementing a translaminar facet screw.
Sun, Haolin; Liu, Chun; Liu, Huiling; Bai, Yanjie; Zhang, Zheng; Li, Xuwen; Li, Chunde; Yang, Huilin; Yang, Lei
2017-01-01
Polymethyl methacrylate (PMMA)-augmented cannulated pedicle-screw fixation has been routinely performed for the surgical treatment of lumbar degenerative diseases. Despite its satisfactory clinical outcomes and prevalence, problems and complications associated with high-strength, stiff, and nondegradable PMMA have largely hindered the long-term efficacy and safety of pedicle-screw fixation in osteoporotic patients. To meet the unmet need for better bone cement for cannulated pedicle-screw fixation, a new injectable and biodegradable nanocomposite that was the first of its kind was designed and developed in the present study. The calcium phosphate-based nanocomposite (CPN) exhibited better anti-pullout ability and similar fluidity and dispersing ability compared to clinically used PMMA, and outperformed conventional calcium phosphate cement (CPC) in all types of mechanical properties, injectability, and biodegradability. In term of axial pullout strength, the CPN-augmented cannulated screw reached the highest force of ~120 N, which was higher than that of PMMA (~100 N) and CPC (~95 N). The compressive strength of the CPN (50 MPa) was three times that of CPC, and the injectability of the CPN reached 95%. In vivo tests on rat femur revealed explicit biodegradation of the CPN and subsequent bone ingrowth after 8 weeks. The promising results for the CPN clearly suggest its potential for replacing PMMA in the application of cannulated pedicle-screw fixation and its worth of further study and development for clinical uses. PMID:28490878
Liu, Da; Sheng, Jun; Luo, Yang; Huang, Chen; Wu, Hong-Hua; Zhou, Jiang-Jun; Zhang, Xiao-Jun; Zheng, Wei
2018-03-19
Polymethylmethacrylate (PMMA) is widely used for pedicle screw augmentation in osteoporosis. Until now, there had been no studies of the relationship between screw stability and the distribution and volume of PMMA. The objective of this study was to analyze the relationship between screw stability and the distribution pattern and injected volume of PMMA. This is a biomechanical comparison of injectable pedicle screws with different lateral holes augmented with different volumes of PMMA in cadaveric osteoporotic lumbar vertebrae. Forty-eight osteoporotic lumbar vertebrae were randomly divided into Groups A, B, and C with different pedicle screws (16 vertebrae in each group), and then each group was randomly divided into Subgroups 0, 1, 2, and 3 with different volumes of PMMA (four vertebra with eight pedicles in each subgroup). A pilot hole was prepared in advance using the same method in all samples. Type A and type B pedicle screws were directly inserted into vertebrae in Groups A and B, respectively, and then different volumes of PMMA (0, 1.0, 1.5, and 2.0 mL) were injected through the screws and into vertebrae in Subgroups 0, 1, 2, and 3. The pilot holes were filled with different volumes of PMMA (0, 1.0, 1.5, and 2.0 mL), and then the screws were inserted in Groups C0, C1, C2, and C3. Screw position and distribution of PMMA were evaluated radiographically, and axial pullout tests were performed to measure maximum axial pullout strength (F max ). Polymethylmethacrylate surrounded the anterior one-third of screws in the vertebral body in Groups A1, A2, and A3; the middle one-third of screws in the junction area of the vertebral body and the pedicle in Groups B1, B2, and B3; and the full length of screws evenly in both the vertebral body and the pedicle in Groups C1, C2, and C3. There was no malpositioning of screws or leakage of PMMA in any sample. Two-way analysis of variance revealed that two factors-distribution and volume of PMMA-significantly influenced F max (p<.05) but that they were not significantly correlated (p=.088). F max values in groups using augmentation with PMMA values significantly improved compared with those in groups without PMMA (p<.05). Polymethylmethacrylate can significantly enhance the stability of different injectable pedicle screws in osteoporotic lumbar vertebrae, and screw stability is significantly correlated with the distribution pattern and the injected volume of PMMA. The closer the PMMA to the pedicle and the greater the quantity of injected PMMA, the greater is the pedicle screw stability. Injection of 2.0 mL of PMMA through screws with four lateral 180° holes or of 1.0 mL of PMMA through screws with six lateral 180° holes increases the stability of pedicle screws. Copyright © 2018 Elsevier Inc. All rights reserved.
Perfusion pressure of a new cannulating fenestrated pedicle screw during cement augmentation.
Wang, Zhirong; Zhang, Wen; Xu, Hao; Lu, Aiqing; Yang, Huilin; Luo, Zong-Ping
2018-06-18
Cannulating fenestrated pedicle screws are effective for fixating osteoporotic vertebrae. However, a major limitation is the excessive pressure required to inject a sufficient amount of cement into the vertebral body through the narrow hole of a pedicle screw. We have recently proposed a new cannulating fenestrated pedicle screw with a large hole diameter and a matched inner pin for screw-strength maintenance. Our purpose was to determine whether the new screw can significantly reduce bone-cement perfusion pressure during cement augmentation, METHODS: Two different methods were used to examine perfusion pressure. Hagen-Poisseuille's flow model in a tube was used to calculate pressure drop in the bone-cement channel. Experimentally, both Newtonian silicone oil and bone-cement (polymethyl methacrylate) were tested using a cement pusher through the cannulating screw at a constant rate of 2 ml/min. The internal hollow portion of the screw was the bottleneck of the perfusion, and the new design significantly reduced the perfusion pressure. Specifically, perfusion pressure dropped by 59% (P < 0.05) when diameter size was doubled. The new design effectively improved the application of bone-cement augmentation with the ease of bone-cement perfusion, thereby enhancing operational safety. Copyright © 2018. Published by Elsevier Ltd.
Adaptive remodeling at the pedicle due to pars fracture: a finite element analysis study.
İnceoğlu, Serkan; Mageswaran, Prasath; Modic, Michael T; Benzel, Edward C
2014-09-01
Spondylolysis is a common condition among the general population and a major cause of back pain in young athletes. This condition can be difficult to detect with plain radiography and has been reported to lead to contralateral pars fracture or pedicle fracture in the terminal stages. Interestingly, some patients with late-stage spondylolysis are observed to have radiographic or CT evidence of a sclerotic pedicle on the side contralateral to the spondylolysis. Although computational studies have shown stress elevation in the contralateral pedicle after a pars fracture, it is not known if these changes would cause sclerotic changes in the contralateral pedicle. The objective of this study was to investigate the adaptive remodeling process at the pedicle due to a contralateral spondylolysis using finite element analysis. A multiscale finite element model of a vertebra was obtained by combining a continuum model of the posterior elements with a voxel-based pedicle section. Extension loading conditions were applied with or without a fracture at the contralateral pars to analyze the stresses in the contralateral pedicle. A remodeling algorithm was used to simulate and assess density changes in the contralateral pedicle. The remodeling algorithm demonstrated an increase in bone formation around the perimeter of the contralateral pedicle with some localized loss of mass in the region of cancellous bone. The authors' results indicated that a pars fracture results in sclerotic changes in the contralateral pedicle. Such a remodeling process could increase overall bone mass. However, focal bone loss in the region of the cancellous bone of the pedicle might predispose the pedicle to microfractures. This phenomenon explains, at least in part, the origin of pedicle stress fractures in the sclerotic contralateral pedicles of patients with unilateral spondylolysis.
Costa, Francesco; Ortolina, Alessandro; Galbusera, Fabio; Cardia, Andrea; Sala, Giuseppe; Ronchi, Franco; Uccelli, Carlo; Grosso, Rossella; Fornari, Maurizio
2016-02-01
Pedicle screws with polymethyl methacrylate (PMMA) cement augmentation have been shown to significantly improve the fixation strength in a severely osteoporotic spine. However, the efficacy of screw fixation for different cement augmentation techniques remains unknown. This study aimed to determine the difference in pullout strength between different cement augmentation techniques. Uniform synthetic bones simulating severe osteoporosis were used to provide a platform for each augmentation technique. In all cases a polyaxial screw and acrylic cement (PMMA) at medium viscosity were used. Five groups were analyzed: I) only screw without PMMA (control group); II) retrograde cement pre-filling of the tapped area; III) cannulated and fenestrate screw with cement injection through perforation; IV) injection using a standard trocar of PMMA (vertebroplasty) and retrograde pre-filling of the tapped area; V) injection through a fenestrated trocar and retrograde pre-filling of the tapped area. Standard X-rays were taken in order to visualize cement distribution in each group. Pedicle screws at full insertion were then tested for axial pullout failure using a mechanical testing machine. A total of 30 screws were tested. The results of pullout analysis revealed better results of all groups with respect to the control group. In particular the statistical analysis showed a difference of Group V (p = 0.001) with respect to all other groups. These results confirm that the cement augmentation grants better results in pullout axial forces. Moreover they suggest better load resistance to axial forces when the distribution of the PMMA is along all the screw combining fenestration and pre-filling augmentation technique. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Reddy, Pathakota Krishnajaneya; Bolla, Vijayalakshmi; Koppolu, Pradeep; Srujan, Peruka
2015-01-01
Replacement of missing maxillary anterior tooth with localized residual alveolar ridge defect is challenging, considering the high esthetic demand. Various soft and hard tissue procedures were proposed to correct alveolar ridge deformities. Novel techniques have evolved in treating these ridge defects to improve function and esthetics. In the present case reports, a novel technique using long palatal connective tissue rolled pedicle graft with demineralized freeze-dried bone allografts (DFDBAs) plus Platelet-rich fibrin (PRF) combination was proposed to correct the Class III localized anterior maxillary anterior alveolar ridge defect. The present technique resulted in predictable ridge augmentation, which can be attributed to the soft and hard tissue augmentation with a connective tissue pedicle and DFDBA plus PRF combination. This technique suggests a variation in roll technique with DFDBA plus PRF and appears to promise in gaining predictable volume in the residual ridge defect and can be considered for the treatment of moderate to severe maxillary anterior ridge defects. PMID:26015679
Metzger, Melodie F.; Robinson, Samuel T.; Svet, Mark T.; Liu, John C.; Acosta, Frank L.
2015-01-01
Study Design Biomechanical cadaveric study. Objective Clinical studies indicate that using less-rigid fixation techniques in place of the standard all-pedicle screw construct when correcting for scoliosis may reduce the incidence of proximal junctional kyphosis and improve patient outcomes. The purpose of this study is to investigate whether there is a biomechanical advantage to using supralaminar hooks in place of pedicle screws at the upper-instrumented vertebrae in a multilevel thoracic construct. Methods T7–T12 spines were biomechanically tested: (1) intact; (2) following a two-level pedicles screw fusion from T9 to T11; and after proximal extension of the fusion to T8–T9 with (3) bilateral supra-laminar hooks, (4) a unilateral hook + unilateral screw hybrid, or (5) bilateral pedicle screws. Specimens were nondestructively loaded while three-dimensional kinematics and intradiscal pressure at the supra-adjacent level were recorded. Results Supra-adjacent hypermobility was reduced when bilateral hooks were used in place of pedicle screws at the upper-instrumented level, with statistically significant differences in lateral bending and torsion (p < 0.05 and p < 0.001, respectively). Disk pressures in the supra-adjacent segment were not statistically different among top-off techniques. Conclusions The use of supralaminar hooks at the top of a multilevel posterior fusion construct reduces the stress at the proximal uninstrumented motion segment. Although further data is needed to provide a definitive link to the clinical occurrence of PJK, this in vitro study demonstrates the potential benefit of “easing” the transition between the stiff instrumented spine and the flexible native spine and is the first to demonstrate these results with laminar hooks. PMID:27190735
Surgical Navigation Technology Based on Augmented Reality and Integrated 3D Intraoperative Imaging
Elmi-Terander, Adrian; Skulason, Halldor; Söderman, Michael; Racadio, John; Homan, Robert; Babic, Drazenko; van der Vaart, Nijs; Nachabe, Rami
2016-01-01
Study Design. A cadaveric laboratory study. Objective. The aim of this study was to assess the feasibility and accuracy of thoracic pedicle screw placement using augmented reality surgical navigation (ARSN). Summary of Background Data. Recent advances in spinal navigation have shown improved accuracy in lumbosacral pedicle screw placement but limited benefits in the thoracic spine. 3D intraoperative imaging and instrument navigation may allow improved accuracy in pedicle screw placement, without the use of x-ray fluoroscopy, and thus opens the route to image-guided minimally invasive therapy in the thoracic spine. Methods. ARSN encompasses a surgical table, a motorized flat detector C-arm with intraoperative 2D/3D capabilities, integrated optical cameras for augmented reality navigation, and noninvasive patient motion tracking. Two neurosurgeons placed 94 pedicle screws in the thoracic spine of four cadavers using ARSN on one side of the spine (47 screws) and free-hand technique on the contralateral side. X-ray fluoroscopy was not used for either technique. Four independent reviewers assessed the postoperative scans, using the Gertzbein grading. Morphometric measurements of the pedicles axial and sagittal widths and angles, as well as the vertebrae axial and sagittal rotations were performed to identify risk factors for breaches. Results. ARSN was feasible and superior to free-hand technique with respect to overall accuracy (85% vs. 64%, P < 0.05), specifically significant increases of perfectly placed screws (51% vs. 30%, P < 0.05) and reductions in breaches beyond 4 mm (2% vs. 25%, P < 0.05). All morphometric dimensions, except for vertebral body axial rotation, were risk factors for larger breaches when performed with the free-hand method. Conclusion. ARSN without fluoroscopy was feasible and demonstrated higher accuracy than free-hand technique for thoracic pedicle screw placement. Level of Evidence: N/A PMID:27513166
Lehman, Ronald A; Kang, Daniel G; Wagner, Scott C; Paik, Haines; Cardoso, Mario J; Bernstock, Joshua D; Dmitriev, Anton E
2015-07-01
Transverse connectors (TCs) are often used to improve the rigidity of posterior spinal instrumentation as previous investigations have suggested that TCs enhance torsional rigidity in long-segment thoracic constructs. Posterior osteotomies, such as pedicle subtraction osteotomy (PSO), are used in severe thoracic deformities and provide a significant amount of correction; as a consequence, however, PSOs also induce three-column spinal instability. In theory, augmentation of longitudinal constructs with TC after a thoracic PSO may provide additional rigidity, but the concept has not been previously evaluated. To evaluate the biomechanical contribution of TC to the rigidity of a long-segment pedicle screw-rod construct after a thoracic PSO. An in vitro fresh-frozen human cadaveric biomechanical analysis. Seven human cadaveric thoracic spines were prepared and instrumented from T4-T10 with bilateral pedicle screws/rods and a PSO was performed at T7. Intact range of motion (ROM) testing was performed with nondestructive loading and analyzed by loading modality (axial rotation [AR], flexion/extension [FE], and lateral bending [LB]). Range of motion analysis was performed in the unaugmented construct, the construct augmented with one TC, and the construct augmented with two TCs. After PSO and an unaugmented longitudinal pedicle screw-rod construct, T4-T10 (overall construct) and T6-T8 (PSO site) ROMs were significantly reduced in all planes of motion compared with intact condition (AR: 11.8° vs. 31.7°; FE: 2.4° vs. 12.3°; 3.4° vs. 17.9°, respectively, p<.05). Augmentation of longitudinal construct with either one or two TCs did not significantly increase construct rigidity in FE or LB compared with the unaugmented construct (p>.05). In contrast, during AR, global ROM was significantly reduced by 43% and 48% at T6-T8 (1.7° and 1.2° vs. 2.38°, respectively) after addition of one and two TCs (p<.05), respectively. One TC did not significantly reduce torsional ROM from the intact state. Two TCs significantly improved torsional rigidity of the entire construct and at the PSO site, with no differences in rigidity for FE and LB or with the addition of only one TC. In the setting of a PSO and long-segment pedicle screw-rod construct, augmentation with at least two TCs should be considered to improve torsional rigidity. Published by Elsevier Inc.
Latissimus dorsi flap for total autologous immediate breast reconstruction without implants.
Santanelli di Pompeo, Fabio; Laporta, Rosaria; Sorotos, Michail; Pagnoni, Marco; Falesiedi, Federica; Longo, Benedetto
2014-12-01
The latissimus dorsi flap provides suitable recipient tissue for fat transfer, with a good blood supply and a reasonable volume of host tissue to inject into. The authors present their experience with use of the pedicled latissimus dorsi flap for fat grafting in total autologous immediate breast reconstruction without implants. From 2010 to 2013, 23 patients underwent breast reconstruction with primary fat augmented latissimus dorsi flaps (21 unilateral procedures and two bilateral procedures). Mean patient age was 52.3 years (range, 39 to 68 years); mean body mass index was 24.77 kg/m2 (range, 21.5 to 28.7 kg/m2). Fat was harvested using the Coleman technique with 10-ml syringes and injected into the adipose layer and muscle fascia of the latissimus dorsi flap skin paddle with 1-ml syringes. The mean size of the harvested skin paddle was 19.7 × 11.04 cm (range, 18 × 10 cm to 21 × 12 cm). Mean operative time was 2.62 hours (range, 2.10 to 3.20 hours) and 4.12 hours (range, 4.10 to 4.15 hours) for unilateral and bilateral reconstructions, respectively. Mean harvested fat volume was 126 ml (range, 90 to 180 ml), and mean injected fat volume was 101 ml (range, 60 to 150 ml). All flaps healed uneventfully, no seroma occurred at the flap donor-site, and no fat grafting-related complications were observed. To the best of the authors' knowledge, this is the first report in which fat transfer was used to achieve immediate latissimus dorsi flap volume augmentation as an alternative for total autologous reconstruction, avoiding implant-related complications.
Kuhns, Craig A; Reiter, Michael; Pfeiffer, Ferris; Choma, Theodore J
2014-02-01
Study Design Biomechanical study of pedicle screw fixation in osteoporotic bone. Objective To investigate whether it is better to tap or not tap osteoporotic bone prior to placing a cement-augmented pedicle screw. Methods Initially, we evaluated load to failure of screws placed in cancellous bone blocks with or without prior tapping as well as after varying the depths of tapping prior to screw insertion. Then we evaluated load to failure of screws placed in bone block models with a straight-ahead screw trajectory as well as with screws having a 23-degree cephalad trajectory (toward the end plate). These techniques were tested with nonaugmented (NA) screws as well as with bioactive cement (BioC) augmentation prior to screw insertion. Results In the NA group, pretapping decreased fixation strength in a dose-dependent fashion. In the BioC group, the tapped screws had significantly greater loads to failure (p < 0.01). Comparing only the screw orientation, the screws oriented at 23 degrees cephalad had a significantly higher failure force than their respective counterparts at 0 degrees (p < 0.01). Conclusions Standard pedicle screw fixation is often inadequate in the osteoporotic spine, but this study suggests tapping prior to cement augmentation will substantially improve fixation when compared with not tapping. Angulating screws more cephalad also seems to enhance aging spine fixation.
Charles, Y P; Pelletier, H; Hydier, P; Schuller, S; Garnon, J; Sauleau, E A; Steib, J-P; Clavert, P
2015-05-01
Vertebroplasty prefilling or fenestrated pedicle screw augmentation can be used to enhance pullout resistance in elderly patients. It is not clear which method offers the most reliable fixation strength if axial pullout and a bending moment is applied. The purpose of this study is to validate a new in vitro model aimed to reproduce a cut out mechanism of lumbar pedicle screws, to compare fixation strength in elderly spines with different cement augmentation techniques and to analyze factors that might influence the failure pattern. Six human specimens (82-100 years) were instrumented percutaneously at L2, L3 and L4 by non-augmented screws, vertebroplasty augmentation and fenestrated screws. Cement distribution (2 ml PMMA) was analyzed on CT. Vertebral endplates and the rod were oriented at 45° to the horizontal plane. The vertebral body was held by resin in a cylinder, linked to an unconstrained pivot, on which traction (10 N/s) was applied until rupture. Load-displacement curves were compared to simultaneous video recordings. Median pullout forces were 488.5 N (195-500) for non-augmented screws, 643.5 N (270-1050) for vertebroplasty augmentation and 943.5 N (750-1084) for fenestrated screws. Cement augmentation through fenestrated screws led to significantly higher rupture forces compared to non-augmented screws (P=0.0039). The pullout force after vertebroplasty was variable and linked to cement distribution. A cement bolus around the distal screw tip led to pullout forces similar to non-augmented screws. A proximal cement bolus, as it was observed in fenestrated screws, led to higher pullout resistance. This cement distribution led to vertebral body fractures prior to screw pullout. The experimental setup tended to reproduce a pullout mechanism observed on radiographs, combining axial pullout and a bending moment. Cement augmentation with fenestrated screws increased pullout resistance significantly, whereas the fixation strength with the vertebroplasty prefilling method was linked to the cement distribution. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Zhang, Bo; Xie, Qing-yun; Wang, Cai-ru; Liu, Jin-biao; Liao, Dong-fa; Jiang, Kai; Lei, Wei; Pan, Xian-ming
2013-01-01
Background It was reported that expansive pedicle screw (EPS) and polymethylmethacrylate-augmented pedicle screw (PMMA-PS) could be used to increase screw stability in osteoporosis. However, there are no studies comparing the two kinds of screws in vivo. Thus, we aimed to compare biomechanical and interfacial performances of EPS and PMMA-PS in osteoporotic sheep spine. Methodology/Principal Findings After successful induction of osteoporotic sheep, lumbar vertebrae in each sheep were randomly divided into three groups. The conventional pedicle screw (CPS) was inserted directly into vertebrae in CPS group; PMMA was injected prior to insertion of CPS in PMMA-PS group; and the EPS was inserted in EPS group. Sheep were killed and biomechanical tests, micro-CT analysis and histological observation were performed at both 6 and 12 weeks post-operation. At 6-week and 12-week, screw stabilities in EPS and PMMA-PS groups were significantly higher than that in CPS group, but there were no significant differences between EPS and PMMA-PS groups at two study periods. The screw stability in EPS group at 12-week was significantly higher than that at 6-week. The bone trabeculae around the expanding anterior part of EPS were more and denser than that in CPS group at 6-week and 12-week. PMMA was found without any degradation and absorption forming non-biological “screw-PMMA-bone” interface in PMMA-PS group, however, more and more bone trabeculae surrounded anterior part of EPS improving local bone quality and formed biological “screw-bone” interface. Conclusions/Significance EPS can markedly enhance screw stability with a similar effect to the traditional method of screw augmentation with PMMA in initial surgery in osteoporosis. EPS can form better biological interface between screw and bone than PMMA-PS. In addition, EPS have no risk of thermal injury, leakage and compression caused by PMMA. We propose EPS has a great application potential in augmentation of screw stability in osteoporosis in clinic. PMID:24086381
[Pedicled versus free TRAM flap for breast reconstruction].
Galla, T J; Lukas, B; Feller, A M
1999-03-01
In breast reconstruction, the free TRAM-flap offers many advantages over the pedicled TRAM-flap. Due to its superior perfusion, the free flap rarely develops necrosis. Shaping of the flap is easier due to the lack of the thick muscle pedicle. Because the rectus muscle is spared, there is minimal donor site morbidity. However, the necessary microvascular anastomoses reduced the acceptance of the free TRAM-flap. During a 13-months period, 51 breast reconstructions were performed in 41 patients, 31 unilateral and ten bilateral. 45 flaps served for delayed reconstruction and six flaps for immediate reconstruction. The operations were performed by two teams working simultaneously. The average operating time was 3.9 hours for unilateral and 6.9 hours for bilateral delayed reconstruction. For immediate reconstruction, 6.2 and 6.3 hours were required for uni- and bilateral procedures, respectively. In 38 flaps, the thoracodorsal vessels served as recipient vessels; 13 flaps were anastomosed to the internal mammary artery and vein. Postoperative complications were observed in 13 patients. Three vessel anastomoses had to be revised. In one flap, a partial necrosis occurred; in two flaps hematoma evacuation was necessary. Two patients suffered from fat necroses at the abdomen and one umbilicus was lost. Skin irritations and seromas at the abdomen occurred in five patients. Pulmonary embolism was diagnosed in one patient three weeks postoperatively. Abdominal hernias or bulging in the epigastric area were not observed up to 15 months after reconstruction. These results reveal a low complication rate for breast reconstruction with the free TRAM-flap. The advantages of this technique as compared to the pedicled technique are discussed.
Pedicled buccal fat pad for the augmentation of facial depression deformity: A case report.
Komatsu, Seiji; Ikemura, Kou; Kimata, Yoshihiro
2017-07-01
Tissue augmentation of facial depression deformities can be achieved by volume replacement with autologous fat injection, dermal filler injection, etc. Here, we report a case of tissue augmentation of a facial depression deformity using a pedicled buccal fat pad (BFP). A 64-year-old woman was referred with a chief complaint of facial depression deformity. Her molars had been removed at another hospital 12 years prior to this referral, and the patient suffered from a left cheek depression deformity as a sequela of a postextraction infection. An incision was made in the left gingivobuccal sulcus under local anesthesia, and BFP was carefully excised from its normal location. The subcutaneous scar tissue was dissected, and a pocket was created via the same mucosal incision. BFP was then pushed into the pocket. The depression deformity immediately disappeared postoperatively. The transplanted BFP remained unabsorbed and soft 43 months postoperatively. The patient did not have any complications. This novel procedure has 2 advantages. First, the pedicled BFP is a vascularized tissue and is not absorbed postoperatively; control of contour is easy, and only 1 treatment session is required. Complications associated with fat necrosis can be avoided. Second, only a single intraoral incision is required; the risk of donor-site morbidity is very low, and scar formation does not occur on exposed skin. Third, this procedure can be performed without special instruments and equipment. The main disadvantages are limited rotation arc and volume of pedicled BFP. Despite its limited application, this procedure is simple and useful, with low invasiveness.
Pedicled buccal fat pad for the augmentation of facial depression deformity
Komatsu, Seiji; Ikemura, Kou; Kimata, Yoshihiro
2017-01-01
Abstract Rationale: Tissue augmentation of facial depression deformities can be achieved by volume replacement with autologous fat injection, dermal filler injection, etc. Here, we report a case of tissue augmentation of a facial depression deformity using a pedicled buccal fat pad (BFP). Patient concerns: A 64-year-old woman was referred with a chief complaint of facial depression deformity. Diagnoses: Her molars had been removed at another hospital 12 years prior to this referral, and the patient suffered from a left cheek depression deformity as a sequela of a postextraction infection. Interventions: An incision was made in the left gingivobuccal sulcus under local anesthesia, and BFP was carefully excised from its normal location. The subcutaneous scar tissue was dissected, and a pocket was created via the same mucosal incision. BFP was then pushed into the pocket. Outcomes: The depression deformity immediately disappeared postoperatively. The transplanted BFP remained unabsorbed and soft 43 months postoperatively. The patient did not have any complications. Lessons: This novel procedure has 2 advantages. First, the pedicled BFP is a vascularized tissue and is not absorbed postoperatively; control of contour is easy, and only 1 treatment session is required. Complications associated with fat necrosis can be avoided. Second, only a single intraoral incision is required; the risk of donor-site morbidity is very low, and scar formation does not occur on exposed skin. Third, this procedure can be performed without special instruments and equipment. The main disadvantages are limited rotation arc and volume of pedicled BFP. Despite its limited application, this procedure is simple and useful, with low invasiveness. PMID:28746209
Shao, Zhen-Xuan; He, Wei; He, Shao-Qi; Lin, Sheng-Lei; Huang, Zhe-Yu; Tang, Hong-Chao; Ni, Wen-Fei; Wang, Xiang-Yang; Wu, Ai-Min
2017-07-21
The incidence of lumbar disc degeneration disease has increased in recent years. Lumbar interbody fusion using two unilateral pedicle screws and a translaminar facet screw fixation has advantages of minimal invasiveness and lower costs compared with the traditional methods. Moreover, a method guided by a three-dimensional (3D) navigation template may help us improve the surgical accuracy and the success rate. This is the first randomised study using a 3D navigation template to guide a unilateral lumbar pedicle screw with contralateral translaminar facet screw fixation. Patients who meet the criteria of the surgery will be randomly divided into experimental groups and control groups by a computer-generated randomisation schedule. We will preoperatively design an individual 3D navigation template using CATIA software and MeditoolCreate. The following primary outcomes will be collected: screw angles compared with the optimal screw trajectories in 3D digital images, length of the wound incision, operative time, intraoperative blood loss and complications. The following secondary outcomes will be collected: visual analogue scale (VAS) for back pain, VAS for leg pain and the Oswestry Disability Index. These parameters will be evaluated on day 1 and then 3, 6, 12 and 24 months postoperatively. The study has been reviewed and approved by the institutional ethics review board of the Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University. The results will be presented at scientific communities and peer-reviewed journals. ChiCTR-IDR-17010466. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Zhang, Xin-Liang; Huang, Da-Geng; Wang, Xiao-Dong; Zhu, Jin-Wen; Li, Yi-Bing; He, Bao-Rong; Hao, Ding-Jun
2017-04-01
Ponticulus posticus is a common anatomic variation that can be mistaken for a broad posterior arch during C1 pedicle screw placement. When the atlas lateral mass screws are placed via the posterior arch, injury to the vertebral artery may result. To our knowledge, there are few clinical studies that have analyzed the feasibility of C1 pedicle screw fixation in patients with ponticulus posticus, in clinical practice. To evaluate the feasibility of inserting a C1 pedicle screw in patients with ponticulus posticus. Between January 2008 and January 2012, 11 consecutive patients with atlantoaxial instability, and with a ponticulus posticus at C1, underwent posterior fusion surgery in our institution. According to preoperative computed tomography (CT) reconstruction, a complete ponticulus posticus was found unilaterally in nine patients and bilaterally in two. Postoperative CT reconstructive imaging was performed to assess whether C1 pedicle screw placement was successful. Patients were followed up at regular intervals and evaluated for symptoms of ponticulus posticus syndrome. Thirteen C1 pedicles (atlas vertebral artery groove), each with a complete ponticulus posticus, were successfully inserted with thirteen 3.5- or 4.0-mm diameter pedicle screws, without resection of the bony anomaly. No intraoperative complications (venous plexus, vertebral artery, or spinal cord injury) occurred. The mean follow-up period was 21 (range 14-30) months. Postoperative CT reconstructive images showed that all 13 pedicle screws were inserted in the C1 pedicles without destruction of the atlas pedicle cortical bone. In the follow-up period, none of the patients demonstrated clinical symptoms of ponticulus posticus syndrome or developed bone fusion. Three-dimensional CT imaging should be considered prior to C1 pedicle screw fixation in patients with ponticulus posticus, to avoid mistaking the ponticulus posticus for a widened dorsal arch of the atlas. If there is no ponticulus posticus syndrome preoperatively, C1 pedicle screw fixation can be successfully performed without removing the bony anomaly.
2011-01-01
Background The operative treatment of adult degenerative scoliosis combined with osteoporosis increase following the epidemiological development. Studies have confirmed that screws in osteoporotic spines have significant lower-screw strength with more frequent screw movements within the vertebra than normal spines. Screws augmented with Polymethylmethacrylate (PMMA) or with autogenous bone can offer more powerful corrective force and significant advantages. Methods A retrospective analysis was conducted on 31 consecutive patients with degenerative lumbar scoliosis combined with osteoporosis who had surgery from December 2000. All had a minimum of 2-year follow-up. All patients had posterior approach surgery. 14 of them were fixed with pedicle screw by augmentation with Polymethylmethacrylate (PMMA) and the other 17 patients with autogenous bone. Age, sex and whether smoking were similar between the two groups. Surgical time, blood loss, blood transfusion, medical cost, post surgery ICU time, hospital day, length of oral pain medicines taken, Pre-and postoperative Oswestry disability index questionnaire and surgical revision were documented and compared. Preoperative, postoperative and final follow up Cobb angle, sagittal lumbar curve, correction rate, and Follow up Cobb loss were also compared. Results No significant differences were found between the autogenous bone group and Polymethylmethacrylate group with regards to all the targets above except for length of oral pain medicines taken and surgery cost. 2 patients were seen leakage during operation, but there is neither damage of nerve nor symptom after operation. No revision was needed. Conclusion Both augmentation pedicle screw with Polymethylmethacrylate (PMMA) and autogenous bone treating degenerative lumbar scoliosis combined with osteoporosis can achieve a good surgical result. Less oral pain medicines taken are the potential benefits of Polymethylmethacrylate augmentation, but that is at the cost of more medical spending. PMID:22188765
Xie, Yang; Fu, Qiang; Chen, Zi-qiang; Shi, Zhi-cai; Zhu, Xiao-dong; Wang, Chuan-feng; Li, Ming
2011-12-21
The operative treatment of adult degenerative scoliosis combined with osteoporosis increase following the epidemiological development. Studies have confirmed that screws in osteoporotic spines have significant lower-screw strength with more frequent screw movements within the vertebra than normal spines. Screws augmented with polymethylmethacrylate (PMMA) or with autogenous bone can offer more powerful corrective force and significant advantages. A retrospective analysis was conducted on 31 consecutive patients with degenerative lumbar scoliosis combined with osteoporosis who had surgery from December 2000. All had a minimum of 2-year follow-up. All patients had posterior approach surgery. 14 of them were fixed with pedicle screw by augmentation with polymethylmethacrylate (PMMA) and the other 17 patients with autogenous bone. Age, sex and whether smoking were similar between the two groups. Surgical time, blood loss, blood transfusion, medical cost, post surgery ICU time, hospital day, length of oral pain medicines taken, Pre-and postoperative Oswestry disability index questionnaire and surgical revision were documented and compared. Preoperative, postoperative and final follow up Cobb angle, sagittal lumbar curve, correction rate, and Follow up Cobb loss were also compared. No significant differences were found between the autogenous bone group and polymethylmethacrylate group with regards to all the targets above except for length of oral pain medicines taken and surgery cost. 2 patients were seen leakage during operation, but there is neither damage of nerve nor symptom after operation. No revision was needed. Both augmentation pedicle screw with polymethylmethacrylate (PMMA) and autogenous bone treating degenerative lumbar scoliosis combined with osteoporosis can achieve a good surgical result. Less oral pain medicines taken are the potential benefits of polymethylmethacrylate augmentation, but that is at the cost of more medical spending.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garty, I.; Koren, A.; Moguilner, G.
1985-08-01
A case of unilateral nearly total hypoperfusion of the left lung in a 13-month-old girl is presented. The combination of the lung hypoperfusion and accumulation of the Tc-99m MDP and Ga-67 citrate in the same area suggested the preoperative diagnosis of mediastinal neuroblastoma. Explorative thoracotomy revealed the presence of a neuroblastoma compressing the left lung pedicle. The described scintigraphic appearance in the pediatric age group is suggested as typical of mediastinal neuroblastoma. This pathology should be included in the following gamuts in nuclear medicine: unilateral decrease or absent lung perfusion, unilateral diffuse chest uptake of Ga-67 citrate, and unilateral pulmonarymore » uptake in bone scintigraphy.« less
Wu, Xiao-Tian; Chen, Nong; Pan, Fu-Gen; Liu, Zuo-Qing; He, Xiao-Jian
2017-03-25
To investigate the feasibility and therapeutic effect of subcutaneous pedicle screw-rod system with modified placement in treatment of Tile B pelvic fractures. From June 2014 to August 2015, 14 patients with Tile B pelvic fractures were treated by subcutaneous pedicle screw-rod system with modified placement in the anterior inferior iliac spine and pubic tubercle. There were 8 males and 6 females, aged from 23 to 65 years with an average of 42 years. Operative time, intraoperative blood loss, fracture healing and postoperative complication were observed and clinical effects were evaluated by Matta reduction standard and Majeed score. All patients were followed up from 8 to 15 months with an average of 10.5 months. Operative time was 25 to 45 min with an average of 32 min;intraoperative blood loss was 10 to 35 ml with an average of 18 ml. All fractures got primary healing and healed time was 9 to 14 weeks with an average of 12.5 weeks. No postoperative incision infection, internal fixation failure and ectopic ossification were found, 4 cases occurred unilateral lateral femoral cutaneous nerve injury and 1 case occurred unilateral femoral nerve paralysis, but all restored finally. According to Matta criteria, reduction was excellent in 7 cases, good in 5 cases, fair in 2 case. According to Majeed score system, the functional evaluation at last follow-up was excellent in 5 cases, good in 7 cases, fair in 2 cases with the average score of 81.50±8.05. Subcutaneous pedicle screw-rod system with modified placement in the anterior inferior iliac spine and pubic tubercle have advantages of strong reduction, less trauma and complications, and is a promising surgical method in the treatment of Tile B pelvic fractures.
Roukis, Thomas S; Kang, Rachel B
2016-01-01
Tibiotalocalcaneal arthrodesis stabilized with retrograde intramedullary nail fixation is associated with a high incidence of complications. This is especially true when performed with a bulk structural allograft and poor soft tissue quality. In select high-risk limb salvage cases, we have augmented tibiotalocalcaneal arthrodesis procedures stabilized using retrograde intramedullary nail fixation with a vascularized pedicled fibular onlay bone graft. We present the data from 10 such procedures with a mean follow-up period of 10.9 ± 5.4 (range 6 to 20) months involving 10 patients (9 males and 1 female). The etiology was avascular osteonecrosis of the talus and/or distal tibia and a resultant large volume cavitary bone defect (8 ankles), severe equinocavovarus contracture (1 ankle), and failed total ankle replacement (1 ankle). A frozen femoral head bulk allograft was used twice, a whole frozen talus allograft once, and a freeze-dried calcaneal allograft once. The fibula was mobilized with intact musculoperiosteal perforating branches of the peroneal artery as a vascularized pedicle onlay bone graft fixated with a screw and washer construct. The mean fibular graft length was 10.2 ± 2.3 cm. The mean interval to radiographic fusion was 2.6 ± 0.6 months and to weightbearing was 3.1 ± 1.4 months. Two stable bulk allograft-host bone and fibular graft-host bone nonunions occurred after intramedullary nail hardware failure. Tibiotalocalcaneal arthrodesis augmented by vascularized pedicled fibular graft stabilized with retrograde compression intramedullary nail fixation offers a reliable option for complex salvage situations when few other options exist. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Timing of PMMA cement application for pedicle screw augmentation affects screw anchorage.
Schmoelz, Werner; Heinrichs, Christian Heinz; Schmidt, Sven; Piñera, Angel R; Tome-Bermejo, Felix; Duart, Javier M; Bauer, Marlies; Galovich, Luis Álvarez
2017-11-01
Cement augmentation is an established method to increase the pedicle screw (PS) anchorage in osteoporotic vertebral bodies. The ideal timing for augmentation when a reposition maneuver is necessary is controversial. While augmentation of the PS before reposition maneuver may increase the force applied it on the vertebrae, it bears the risk to impair PS anchorage, whereas augmenting the PS after the maneuver may restore this anchorage and prevent early screw loosening. The purpose of the present study was to evaluate the effect of cement application timing on PS anchorage in the osteoporotic vertebral body. Ten lumbar vertebrae (L1-L5) were used for testing. The left and right pedicles of each vertebra were instrumented with the same PS size and used for pairwise comparison of the two timing points for augmentation. For the reposition maneuver, the left PS was loaded axially under displacement control (2 × ±2 mm, 3 × ±6 mm, 3 × ±10 mm) to simulate a reposition maneuver. Subsequently, both PS were augmented with 2 ml PMMA cement. The same force as measured during the left PS maneuver was applied to the previously augmented right hand side PS [2 × F (±2 mm), 3 × F (±6 mm), 3 × F (±10 mm)]. Both PS were cyclically loaded with initial forces of +50 and -50 N, while the lower force was increased by 5 N every 100 cycles until total failure of the PS. The PS motion was measured with a 3D motion analysis system. After cyclic loading stress, X-rays were taken to identify the PS loosening mechanism. In comparison with PS augmented prior to the reposition maneuver, PS augmented after the reposition maneuver showed a significant higher number of load cycles until failure (5930 ± 1899 vs 3830 ± 1706, p = 0.015). The predominant loosening mechanism for PS augmented after the reposition maneuver was PS toggling with the attached cement cloud within the trabecular bone. While PS augmented prior to the reposition, maneuver showed a motion of the screw within the cement cloud. The time of cement application has an effect on PS anchorage in the osteoporotic vertebral body if a reposition maneuver of the instrumented vertebrae is carried out. PS augmented after the reposition maneuver showed a significant higher number of load cycles until screw loosening.
Ortega-Porcayo, Luis Alberto; Leal-López, Andres; Soriano-López, Miroslava Elizabeth; Gutiérrez-Partida, Carlos Francisco; Ramírez-Barrios, Luis Rodolfo; Soriano-Solis, Sergio; Rodríguez-García, Manuel; Soriano-Solis, Hector Antonio; Soriano-Sánchez, José Antonio
2018-04-01
Retrospective comparative clinical study. This study aimed to assess paraspinal muscle atrophy in patients who underwent minimally invasive transforaminal lumbar interbody fusion (MI-TLIF) and unilateral pedicle screw fixation using a novel contralateral intact muscle-controlled model. The increased incidence of paravertebral lumbar muscle injuries after open techniques has raised the importance of implementing minimally invasive spine surgical techniques using tubular retractors and minimally invasive screw placement. The functional cross-sectional area (FCSA) represents the lean muscle mass; furthermore, FCSA is a useful marker of the contractile ability of a muscle following a spine surgery. However, the benefits of unilateral fixation and MI-TLIF on paraspinal muscles have not been defined. We performed a retrospective imagenological review on eleven patients who underwent unilateral MI-TLIF and unilateral transpedicular screw lumbar placement. FCSAs of the multifidus and erector spinae were measured 1 year after surgery at adjacent levels and were compared to the contralateral intact muscles. Measurement differences between the surgical and nonsurgical sites were compared. The interobserver reliability was calculated using an intraclass correlation coefficient. The mean FCSA at the surgical site was 20.97±5.07 cm 2 at the superior level and 8.89±2.87 cm 2 at the inferior level. The mean FCSA at the contralateral nonsurgical site was 20.15±5.95 cm 2 at the superior level and 9.20±2.66 cm 2 at the inferior level was. The superior and inferior FCSA measurements showed no significant difference between the surgical and nonsurgical sites ( p =0.5, p =0.922, respectively). Using a mini-open tubular approach through the sulcus between the longissimus and iliocostalis, MI-TLIF and unilateral pedicle screw instrumentation produced minimal paraspinal muscle damage at the superior and inferior adjacent levels.
Ortega-Porcayo, Luis Alberto; Leal-López, Andres; Soriano-López, Miroslava Elizabeth; Gutiérrez-Partida, Carlos Francisco; Ramírez-Barrios, Luis Rodolfo; Soriano-Solis, Sergio; Rodríguez-García, Manuel; Soriano-Solis, Hector Antonio
2018-01-01
Study Design Retrospective comparative clinical study. Purpose This study aimed to assess paraspinal muscle atrophy in patients who underwent minimally invasive transforaminal lumbar interbody fusion (MI-TLIF) and unilateral pedicle screw fixation using a novel contralateral intact muscle-controlled model. Overview of Literature The increased incidence of paravertebral lumbar muscle injuries after open techniques has raised the importance of implementing minimally invasive spine surgical techniques using tubular retractors and minimally invasive screw placement. The functional cross-sectional area (FCSA) represents the lean muscle mass; furthermore, FCSA is a useful marker of the contractile ability of a muscle following a spine surgery. However, the benefits of unilateral fixation and MI-TLIF on paraspinal muscles have not been defined. Methods We performed a retrospective imagenological review on eleven patients who underwent unilateral MI-TLIF and unilateral transpedicular screw lumbar placement. FCSAs of the multifidus and erector spinae were measured 1 year after surgery at adjacent levels and were compared to the contralateral intact muscles. Measurement differences between the surgical and nonsurgical sites were compared. The interobserver reliability was calculated using an intraclass correlation coefficient. Results The mean FCSA at the surgical site was 20.97±5.07 cm2 at the superior level and 8.89±2.87 cm2 at the inferior level. The mean FCSA at the contralateral nonsurgical site was 20.15±5.95 cm2 at the superior level and 9.20±2.66 cm2 at the inferior level was. The superior and inferior FCSA measurements showed no significant difference between the surgical and nonsurgical sites (p=0.5, p=0.922, respectively). Conclusions Using a mini-open tubular approach through the sulcus between the longissimus and iliocostalis, MI-TLIF and unilateral pedicle screw instrumentation produced minimal paraspinal muscle damage at the superior and inferior adjacent levels. PMID:29713406
Liu, Jia-Ming; Zhang, Yu; Zhou, Yang; Chen, Xuan-Yin; Huang, Shan-Hu; Hua, Zi-Kai; Liu, Zhi-Li
2017-06-01
Posterior reduction and pedicle screw fixation is a widely used procedure for thoracic and lumbar vertebrae fractures. Usually, the pedicle screws would be removed after the fracture healing and screw tunnels would be left. The aim of this study is to evaluate the effect of screw tunnels on the biomechanical stability of the lumbar vertebral body after pedicle screws removal by finite element analysis (FEA). First, the CT values of the screw tunnels wall in the fractured vertebral bodies were measured in patients whose pedicle screws were removed, and they were then compared with the values of vertebral cortical bone. Second, an adult patient was included and the CT images of the lumbar spine were harvested. Three dimensional finite element models of the L1 vertebra with unilateral or bilateral screw tunnels were created based on the CT images. Different compressive loads were vertically acted on the models. The maximum loads which the models sustained and the distribution of the force in the different parts of the models were recorded and compared with each other. The CT values of the tunnels wall and vertebral cortical bone were 387.126±62.342 and 399.204±53.612, which were not statistically different (P=0.149). The models of three dimensional tetrahedral mesh finite element of normal lumbar 1 vertebra were established with good geometric similarity and realistic appearance. After given the compressive loads, the cortical bone was the first one to reach its ultimate stress. The maximum loads which the bilateral screw tunnels model, unilateral screw tunnel model, and normal vertebral model can sustain were 3.97 Mpa, 3.83 Mpa, and 3.78 Mpa, respectively. For the diameter of the screw tunnels, the model with a diameter of 6.5 mm could sustain the largest load. In addition, the stress distributing on the outside of the cortical bone gradually decreased as the thickness of the tunnel wall increased. Based on the FEA, pedicle screw tunnels would not decrease the biomechanical stability and strength of the vertebral body. A large diameter of screw tunnel and thick tunnel wall were helpful for the biomechanical stability of the vertebral body.
Periodontal considerations for esthetics: edentulous ridge augmentation.
Rosenberg, E S; Cutler, S A
1993-01-01
Edentulous ridge augmentation is a plastic surgical technique that is performed to improve patient esthetics when unsightly, deformed ridges exist. This article describes the etiology of ridge deformities and the many procedures that can be executed to achieve an esthetic, functional result. Historically, soft-tissue mucogingival techniques were described to augment collapsed ridges. Pedicle grafts, free soft-tissue grafts, and subepithelial connective tissue grafts are predictable forms of therapy. More recently, ridge augmentation techniques were developed that regenerate the lost periodontium. These include allografts, bioglasses, guided tissue regenerative procedures, and tissue expansion.
Weiser, Lukas; Huber, Gerd; Sellenschloh, Kay; Viezens, Lennart; Püschel, Klaus; Morlock, Michael M; Lehmann, Wolfgang
2017-11-01
Loosening of pedicle screws is one major complication of posterior spinal stabilisation, especially in the patients with osteoporosis. Augmentation of pedicle screws with cement or lengthening of the instrumentation is widely used to improve implant stability in these patients. However, it is still unclear from which value of bone mineral density (BMD) the stability of pedicle screws is insufficient and an additional stabilisation should be performed. The aim of this study was to investigate the correlation of bone mineral density and pedicle screw fatigue strength as well as to define a threshold value for BMD below which an additional stabilisation is recommended. Twenty-one human T12 vertebral bodies were collected from donors between 19 and 96 years of age and the BMD was measured using quantitative computed tomography. Each vertebral body was instrumented with one pedicle screw and mounted in a servo-hydraulic testing machine. Fatigue testing was performed by implementing a cranio-caudal sinusoidal, cyclic (0.5 Hz) load with stepwise increasing peak force. A significant correlation between BMD and cycles to failure (r = 0.862, r 2 = 0.743, p < 0.001) as well as for the linearly related fatigue load was found. Specimens with BMD below 80 mg/cm 3 only reached 45% of the cycles to failure and only 60% of the fatigue load compared to the specimens with adequate bone quality (BMD > 120 mg/cm 3 ). There is a close correlation between BMD and pedicle screw stability. If the BMD of the thoracolumbar spine is less than 80 mg/cm 3 , stability of pedicle screws might be insufficient and an additional stabilisation should be considered.
Vargas, Christina R.; Nguyen, John T.; Ashitate, Yoshitomo; Silvestre, Jason; Venugopal, Vivek; Neacsu, Florin; Kettenring, Frank; Frangioni, John V.; Gioux, Sylvain; Lee, Bernard T.
2015-01-01
Background Advances in microsurgical techniques have increased the use of free tissue transfer. Methods of intraoperative flap perfusion assessment, however, still rely primarily on subjective evaluation of traditional clinical parameters. Anastomotic thrombosis, if not expeditiously identified and revised, can result in flap loss with significant associated morbidity. This study aims to evaluate the use of near-infrared (NIR) fluorescence imaging in the assessment of microsurgical anastomotic patency, thrombosis, and vascular revision. Materials and Methods A model of pedicle thrombosis was created using bilateral abdominal flaps isolated on deep superior epigastric vascular pedicles in four Yorkshire pigs. Following flap elevation, microvascular arterial and venous anastomoses were performed unilaterally, preserving an intact contralateral control flap. Thrombosis was induced at the arterial anastomosis site using ferric chloride, and both flaps imaged using NIR fluorescence angiography. The thrombosed vascular segments were subsequently excised and new anastomoses performed to restore flow. Follow-up imaging of both flaps was then obtained to confirm patency using fluorescence imaging technology. Results Pedicled abdominal flaps were created and successful anastomotic thrombosis was induced unilaterally in each pig. Fluorescence imaging technology identified large decreases in tissue perfusion of the thrombosed flap within 2 minutes. After successful revision anastomosis, NIR imaging demonstrated dramatic increase in flow to the reconstructed flap, but intensity did not return to pre-thrombosis levels. Conclusions Early identification of anastomotic thrombosis is important in successful free tissue transfer. Real-time, intraoperative evaluation of flap perfusion, anastomotic thrombosis, and successful revision can be performed using NIR fluorescence imaging. PMID:25571855
New method for maximum mobilization of temporalis muscle flap.
Masic, Tarik; Babajic, Emina; Dervisevic, Almir; Hassouba, Mahmoud
2012-01-01
Pedicled temporalis muscle flap presenting a good flap for closing large craniofacial defects. Careful surgeons usually do not mobilize temporalis muscle flap enough to make appropriate use, fully closure, especially if defect exceeds the median line. Temporalis flap was used in 16 patients, ages ranged between 12 and 76. In all cases defect reconstruction was done by useing new method of extending standard temporal muscle flap. During surgical procedure it is very important to keep periosteal elevator in close contact with the bone. Then, there is no risk for pedicle injury. After vascular pedicle is identified elevating temporal muscle has to be continued by releasing the muscle insertion from the coronoid process. By this way, flap length and arc of rotation is increased. The flap remained viable in all instances. Most of the patients experienced no perioperative complications. There was no major complications or mortality as a result of performed procedures. With this division, flap length was increased at least 2 cm wich is enough for covering defects crossing the midline. Instead of using bilateral temporalis muscle flaps for defect closure, unilateral is sufficient. With this extension of the pedicle length now rotation point is not at the level of the zygomatic arch but lower part mandibular neck.
Sun, Edward; Alkalay, Ron; Vader, David; Snyder, Brian D
2009-06-01
An in vitro biomechanical study. Compare the mechanical behavior of 5 different constructs used to terminate dual-rod posterior spinal instrumentation in resisting forward flexion moment. Failure of the distal fixation construct can be a significant problem for patients undergoing surgical treatment for thoracic hyperkyphosis. We hypothesize that augmenting distal pedicle screws with infralaminar hooks or sublaminar cables significantly increases the strength and stiffness of these constructs. Thirty-seven thoracolumbar (T12 to L2) calf spines were implanted with 5 configurations of distal constructs: (1) infralaminar hooks, (2) sublaminar cables, (3) pedicle screws, (4) pedicle screws+infralaminar hooks, and (5) pedicle screws+sublaminar cables. Progressive bending moment was applied to each construct until failure. The mode of failure was noted and the construct's stiffness and failure load determined from the load-displacement curves. Bone density and vertebral dimensions were equivalent among the groups (F=0.1 to 0.9, P>0.05). One-way analysis of covariance (adjusted for differences in density and vertebral dimension) demonstrated that all of the screw-constructs (screw, screw+hook, and screw+cable) exhibited significantly higher stiffness and ultimate failure loads compared with either sublaminar hook or cable alone (P<0.05). The screw+hook constructs (109+/-11 Nm/mm) were significantly stiffer than either screws alone (88+/-17 Nm/mm) or screw+cable (98+/-13 Nm/mm) constructs, P<0.05. Screw+cable construct exhibited significantly higher failure load (1336+/-328 N) compared with screw constructs (1102+/-256 N, P<0.05), whereas not statistically different from the screw+hook construct (1220+/-75 N). The cable and hook constructs failed by laminar fracture, screw construct failed in uniaxial shear (pullout), whereas the screws+(hooks or wires) failed by fracture of caudal vertebral body. Posterior dual rod constructs fixed distally using pedicle screws were stiffer and stronger in resisting forward flexion compared with cables or hooks alone. Augmenting these screws with either infralaminar hooks or sublaminar cables provided additional resistance to failure.
El Chaar, Edgard; Oshman, Sarah; Cicero, Giuseppe; Castano, Alejandro; Dinoi, Cinzia; Soltani, Leila; Lee, Yoonjung Nicole
Localized ridge resorption, the consequence of socket collapse, following tooth extraction in the anterior maxilla can adversely affect esthetics, function, and future implant placement. Immediate grafting of extraction sockets may help preserve natural ridge contours, but a lack of available soft tissue can compromise the final esthetic outcome. The presented modified rotated palatal pedicle connective tissue flap is a useful technique for simultaneous soft tissue coverage and augmentation of grafted sockets to improve esthetic outcome. This article delineates its advantages through the presentation of a four-case series using this new technique.
Akbar, Saleem; Dhar, Shabir A.
2008-01-01
To assess the efficacy and feasibility of vertebroplasty and posterior short-segment pedicle screw fixation for the treatment of traumatic lumbar burst fractures. Short-segment pedicle screw instrumentation is a well described technique to reduce and stabilize thoracic and lumbar spine fractures. It is relatively a easy procedure but can only indirectly reduce a fractured vertebral body, and the means of augmenting the anterior column are limited. Hardware failure and a loss of reduction are recognized complications caused by insufficient anterior column support. Patients with traumatic lumbar burst fractures without neurologic deficits were included. After a short segment posterior reduction and fixation, bilateral transpedicular reduction of the endplate was performed using a balloon, and polymethyl methacrylate cement was injected. Pre-operative and post-operative central and anterior heights were assessed with radiographs and MRI. Sixteen patients underwent this procedure, and a substantial reduction of the endplates could be achieved with the technique. All patients recovered uneventfully, and the neurologic examination revealed no deficits. The post-operative radiographs and magnetic resonance images demonstrated a good fracture reduction and filling of the bone defect without unwarranted bone displacement. The central and anterior height of the vertebral body could be restored to 72 and 82% of the estimated intact height, respectively. Complications were cement leakage in three cases without clinical implications and one superficial wound infection. Posterior short-segment pedicle fixation in conjunction with balloon vertebroplasty seems to be a feasible option in the management of lumbar burst fractures, thereby addressing all the three columns through a single approach. Although cement leakage occurred but had no clinical consequences or neurological deficit. PMID:18193300
Kuroe, Kazuto; Iino, Shoichiro; Shomura, Kenji; Okubo, Akiro; Sugihara, Kazumasa; Ito, Gakuji
2003-05-01
Collapse of the maxillary minor segment with lateral crossbite is a common feature in patients with repaired unilateral cleft lip/palate because of maxillary alveolar bony defect and palatal scar tissue. Distraction osteogenesis (DOG) is an effective technique of lengthening and augmentation for bone and gingiva. This case report describes the effects of unilateral advancement of the maxillary minor segment by DOG in two patients with the repaired unilateral cleft lip/palate.
Tan, Quan-Chang; Wu, Jian-Wei; Peng, Fei; Zang, Yuan; Li, Yang; Zhao, Xiong; Lei, Wei; Wu, Zi-Xiang
2016-06-01
OBJECTIVE This study investigated the optimum injection volume of polymethylmethacrylate (PMMA) to augment a novel fenestrated pedicle screw (FPS) with diameter-tapered perforations in the osteoporotic vertebral body, and how the distribution characteristics of PMMA affect the biomechanical performance of this screw. METHODS Two types of FPSs were designed (FPS-A, composed of 6 perforations with an equal diameter of 1.2 mm; and FPS-B, composed of 6 perforations each with a tapered diameter of 1.5 mm, 1.2 mm, and 0.9 mm from tip to head. Each of 28 human cadaveric osteoporotic vertebrae were randomly assigned to 1 of 7 groups: FPS-A1.0: FPS-A+1.0 ml PMMA; FPS-A1.5: FPS-A+1.5 ml PMMA; FPS-A2.0: FPS-A+2.0 ml PMMA; FPS-B1.0: FPS-B+1.0 ml PMMA; FPS-B1.5: FPS-B+1.5 ml PMMA; FPS-B2.0: FPS-B+2.0 ml PMMA; and conventional pedicle screws (CPSs) without PMMA. After the augmentation, 3D CT was performed to assess the cement distribution characteristics and the cement leakage rate. Axial pullout tests were performed to compare the maximum pullout force thereafter. RESULTS The CT construction images showed that PMMA bone cement formed a conical mass around FPS-A and a cylindrical mass around FPS-B. When the injection volume was increased from 1.0 ml to 2.0 ml, the distribution region of the PMMA cement was enlarged, the PMMA was distributed more posteriorly, and the risk of leakage was increased. When the injection volume reached 2.0 ml, the risk of cement leakage was lower for screws having diameter-tapered perforations. The pullout strengths of the augmented FPS-A groups and FPS-B groups were higher than that of the CPS group (p < 0.0001). All FPS-B groups had a higher pullout strength than the FPS-A groups. CONCLUSIONS The diameter of the perforations affects the distribution of PMMA cement. The diameter-tapered design enabled PMMA to form larger bone-PMMA interfaces and achieve a relatively higher pullout strength, although statistical significance was not reached. Study results indicated 1.5-ml of PMMA was a conservative volume for PMMA augmentation; more cement injection would significantly increase the risk of cement leakage.
Fölsch, Christian; Goost, Hans; Figiel, Jens; Paletta, Jürgen R J; Schultz, Wolfgang; Lakemeier, Stefan
2012-12-01
Cement augmentation of pedicle screws increases fixation strength in an osteoporotic spine. This study was designed to determine the cement distribution and the correlation between the pull-out strength of the augmented screw and the cement volume within polyurethane (PU) foam. Twenty-eight cannulated pedicle screws (6×45 mm) (Peter Brehm, Erlangen, Germany) with four holes at the distal end of the screw were augmented with the acrylic Stabilit ER Bone Cement Vertebral Augmentation System (DFine Inc., San Jose, CA, USA) and implanted into open-cell rigid PU foam (Pacific Research Laboratories, Vashon Island, WA, USA) with a density of 0.12 g/cm3, resembling severe osteoporosis. Volumetric measurement of the cement with consideration of the distribution around the screws was done with multislice computed tomography scan (Somatom Definition, Siemens, Erlangen, Germany). Pull-out strength was tested with a servohydraulic system (MTS System Corporation, Eden Prairie, MN, USA), and nonaugmented screws served as control. Pearson's correlation coefficient with significance level α=0.05 and one-way analysis of variance test were used. We found a high (r=0.88) and significant (p<0.01) correlation between the cement volume and the pull-out strength, which increased by more than 5-fold with a volume of 3 ml. The correlation appeared linear at least up to 4 ml cement volume and failure always occurred at the cement-bone interface. The cement distribution was symmetric and circular around the most proximal hole, with a distance of 14 mm from the tip, and nearly 90% of the cement was found 6 mm distal and cranial to it. The 95% confidence interval for the relative amount of cement was 37%-41% within 2 mm of the most proximal hole. Compared with the control, a cement volume between 2.0 and 3.0 ml increased the pull-out strength significantly and is relevant for clinical purposes, whereas a volume of 0.5 ml did not. A cement volume beyond 3.0 ml should further increase the pull-out strength because the correlation was linear at least up to 4.0 ml, but the possibility of in vivo cement leakage with increasing volume has to be considered. Pressure-controlled cement application might be a tool to avoid this complication. The cement almost completely penetrated the most proximal perforation.
Lin, Hsi-Hsien; Chang, Ming-Chau; Wang, Shih-Tien; Liu, Chien-Lin; Chou, Po-Hsin
2018-06-01
Polymethylmethacrylate (PMMA) augmentation is a common method to increase pullout strength fixed for osteoporotic spines. However, few papers evaluated whether these pedicle screws migrated with time and functional outcome in these geriatrics following PMMA-augmented pedicle screw fixation. From March 2006 to September 2008, consecutive 64 patients were retrospectively enrolled. VAS and ODI were used to evaluate functional outcomes. Kyphotic angle at instrumented levels and horizontal and vertical distances (HD and VD) between screw tip and anterior and upper cortexes were evaluated. To avoid bias, we used horizontal and vertical migration index (HMI and VMI) to re-evaluate screw positions with normalization by the mean of superior and inferior endplates or anterior and posterior vertebral body height, respectively. Forty-six patients with 282 PMMA-augmented screws were analyzed with mean follow-up of 95 months. Nine patients were further excluded due to bed-ridden at latest follow-up. Twenty-six females and 11 males with mean T score of - 2.7 (range, - 2.6 to - 4.1) and mean age for operation of 77.6 ± 4.3 years (range, 65 to 86). The serial HD and kyphotic angle statistically progressed with time. The serial VD did not statistically change with time (p = 0.23), and neither HMI nor VMI (p = 0.772 and 0.631). Pre-operative DEXA results did not correlate with kyphotic angle. Most patients (80.4%) maintained similar functional outcomes at latest follow-up. The incidence of screws loosening was 2.7% of patients and 1.4% of screws, respectively. The overall incidences of systemic post-operative co-morbidities were 24.3% with overall 20.2 days for hospitalization. Most patients (80%) remained similar functional outcomes at latest follow-up in spite of kyphosis progression. The incidence of implant failure was not high, but the post-operative systemic co-morbidities were higher, which has to be informed before index surgery.
Wang, Song; Wang, Qing; Kang, Jianping; Xiu, Peng; Wang, Gaoju
2014-04-20
An imaging anatomical measurement. To investigate the anatomical feasibility of percutaneous kyphoplasty for lumbar osteoporotic vertebral compression fractures via a unilateral transverse process-pedicle approach (TPA). Kyphoplasty via a unilateral approach has been reported and good clinical results have been achieved. However, because of the lack of an anatomical study, these approaches have yet to be popularized. A total of 150 lumbar vertebral bodies of 30 patients were simulated kyphoplasty on the computed tomographic scans through conventional transpedicle approach (CTA) and the TPA, respectively. Anatomical parameters including the distance between the entry point and the midline of the vertebral body, the puncture inclination angle, and the success rate of puncture were measured and compared. The distance between the entry point and the midline from L1 to L5 lumbar levels varied from 20.6 ± 2.2 mm to 28.6 ± 2.9 mm in the CTA group and from 23.6 ± 2.2 mm to 33.6 ± 2.9 mm in the TPA group. The entry point from L1 to L5 in the TPA group was 3.0 ± 2.1 mm to 5.1 ± 2.7 mm more lateral than that in the CTA group. The medial inclination angles from L1 to L5 were 30.2° ± 6.4° to 47.7° ± 5.4° in the TPA and 15.3° ± 6.0° to 22.8° ± 8.7° in the CTA group. The inclination angles in the TPA group were greater than that in the CTA group and the safe range of the puncture angles was also wider. The success rate was 51.7% in the CTA group and 87.7% in the TPA group. The entry point through a TPA was localized at the midline of the transverse process, 3.0 to 5.1 mm outside the lateral margin of the pedicle projection. Compared with CTA, the puncture inclination angle in the TPA approach was much larger with a wider safe puncture range. The TPA approach allowed an easy puncture to meet or surpass the midline of the lumbar vertebral body. N/A.
Laurent, B; Rouif, M; Giordano, P; Mateu, J
2011-12-01
Vascular complications of the unipedicled TRAM flap pointed out the need for solutions to decrease such occurrences. The flap surgical delay before transfer has been advocated to improve the blood supply but, at the same time, it increases the risk of wound infection at the donor site and imposes a general anesthesia. The DIEP and the free TRAM flap are more complex procedures and need heavy structural resources. Preferential use of the ipsilateral muscular pedicle suggests a lower partial flap necrosis rate. Selective embolization of the deep inferior epigastric arteries prior to surgery realizes an alternative delay and brings a decrease in the vascular complication rate as shown in a study of 40 patients by Scheufler in 2000. We present a series of 69 patients who were reconstructed by means of a delayed pedicled TRAM flap with selective embolization and a predominant use of the ispsilateral pedicle. Sonographic studies performed in 48 patients prior to surgery showed no significative difference in the diameter of the superior epigastic arteries, with or without previous radiotherapy. The mean interval between embolization and surgery was 30 days; the embolization was performed bilateraly in five patients (4 %), and unilaterally in 64 patients (96 %). The mean age of patients was 54 years, radiotherapy was applied in 43 patients (62 %), smoking patients: 11 (16 %), obesity: five (7 %). The ispsilateral pedicled was used in 67 patients (97 %), controlateral pedicle in two patients (3 %). Postoperative flap complications were comprised of partial flap necrosis in two cases (2,9 %), fat necrosis in six cases (8,7 %), impaired wound healing in three cases (4,3 %), abdominal wall weakness in two cases (2,9 %). We compared the present study of ispsilateral delayed pedicled flap to a study from the same authors concerning controlateral pedicled flaps without delay. It has been demonstrated that the complications rate of partial necrosis was divided by four in the first study compared to the second. The preoperative selective embolization of the deep inferior epigastric artery in association with the use of ipsilateral pedicule in TRAM flap decrease the complications rate significatively compared to the controlateral pedicled flap in TRAM flaps. Copyright © 2011 Elsevier Masson SAS. All rights reserved.
Luther, Evan; Urakov, Timur; Vanni, Steven
2018-06-11
Complex traumatic lumbar spine fractures are difficult to manage and typically occur in younger patients. Surgical immobilization for unstable fractures is an accepted treatment but can lead to future adjacent-level disease. Furthermore, large variations in fracture morphology create significant difficulties when attempting fixation. Therefore, a surgical approach that considers both long-term outcomes and fracture type is of utmost importance. We present a novel technique for percutaneous fixation without interbody or posterolateral fusion in a young patient with bilateral pedicle dissociations and an acute-onset incomplete neurologic deficit. A 20-year-old man involved in a motorcycle accident presented with unilateral right lower extremity paresis and sensory loss with intact rectal tone and no saddle anesthesia. Lumbar computed tomography (CT) demonstrated L2 and L3 fractures associated with bilateral pedicle dislocations. Lumbar magnetic resonance imaging showed draping of the conus medullaris/cauda equina anteriorly over the kyphotic deformity at L2 with minimal associated canal stenosis at L2 and L3. He was treated with emergent percutaneous fixation of the fracture segment without interbody or posterolateral fusion. Decompression was not performed because of the negligible amount of canal stenosis and high likelihood of cerebrospinal fluid leakage due to dural tears from the fractures. Surgical fixation of the L2 vertebra was achieved by cannulating the left pedicle with an oversized tap while holding the right pedicle in place with a normal tap and then driving screws into the left and right pedicles, respectively, thus reducing the free-floating fracture segment. At 18 months after surgery, a follow-up CT demonstrated good cortication across the prior pedicle fractures, and the instrumentation was removed without any obvious signs of instability or disruption of the alignment at the thoracolumbar junction. We present a novel technique for percutaneous reduction and fixation of bilateral pedicle fractures with significant dissociation from the vertebral body, associated neural compression from the kyphotic deformity, and minimal spinal canal stenosis. Furthermore, we argue that early fixation and reduction of the fracture prevented irreversible neurologic compromise, and the absence of interbody or posterolateral fusion ultimately preserved the spinal mobility of the patient once the hardware was removed. Georg Thieme Verlag KG Stuttgart · New York.
Pedicled fat flap to increase lateral fullness in upper blepharoplasty.
Sozer, Sadri O; Agullo, Francisco J; Palladino, Humberto; Payne, Phileemon E; Banerji, Soumo
2010-03-01
The eyelid of a young person can be distinguished by the lateral fullness of the upper eyelid. With aging, lateral fullness decreases. Volume restoration in the periorbital area has been previously addressed by fat draping and grafting. More recently, techniques for regaining lateral fullness of the upper eyelid have focused on fat grafting, although effective graft take, reabsorption, and irregularities have been a concern. To address these issues, the concept of pedicled fat draping in the upper eyelid was explored. In a retrospective study from June 2006 to August 2008, 31 patients underwent upper blepharoplasty with augmentation of the lateral fullness with a pedicled fat flap from the central fat pad. The fat from the central compartment was elevated, dissected, and then transposed to the lateral upper eyelid below the orbicularis muscle. All patients were women ranging in age from 43 to 68 years. Pre- and postoperative picture comparison demonstrated a more youthful appearance with increased lateral fullness of the upper eyelids. There were no cases of fat necrosis encountered. Increased volume remained stable over an average of one-year follow-up. No complications were recorded. Transposing a pedicled fat pad from the central compartment laterally has proven to be an effective technique for achieving predictable upper lateral eyelid fullness and thus achieving a long-lasting, more youthful appearance.
[Sacral pressure sores and their treatment].
Bielecki, Marek; Skowroński, Rafał; Skowroński, Jan
2006-01-01
Sacral bed sores still present a serious problem in most surgery departments. They occur mainly in elderly patients of limited mobility. The treatment of such sores extends over long periods of time and therefore involves considerable costs. The material consisted of 11 sacral pressure ulcers treated surgically. The sores occurred in 4 severely disabled patients suffering from proximal third femur fractures, 4 patients with traumatic brain injury (treated in the Intensive Care Unit), and 3 patients suffering from bed sores after spinal cord injury. In 6 patients a fasciocutaneous flap was applied to the sores and in 5 cases a pedicled musculocutaneous gluteus maximus flap. The end results were assessed using Seiler's criteria. Complications of the "seroma" type were observed in 3 patients, and in 2 marginal necrosis. In all our patients complete healing was achieved within 2-4 weeks. On analysing our experience to date in surgical treatment of bed sores we are of the opinion that even extensive sacral sores can be covered with unilateral pedicled flaps provided that they are appropriately planned. Deep sores of the 4th degree sometimes with concomitant osteomyelitis require pedicled muscle flaps or in some cases musculocutaneous flaps to improve local circulation. The preparation of the patient for reconstruction surgery is just as important as the operation itself and therefore such preparation should never be neglected.
Unilateral pseudogynecomastia: an occupational hazard in manual metal-pressing factories?
Spyropoulou, Georgia-Alexandra; Karamatsoukis, Stavros; Foroglou, Pericles
2011-04-01
Five cases of unilateral occupation-related pseudogynecomastia are presented. All the patients in these cases worked in the same metal-pressing factory. One patient with grade 4 unilateral gynecomastia in the right breast presented to the authors' outpatient department asking persistently for surgery. He also reported that all his male colleagues working in the same business (a total of 5) had different degrees of unilateral gynecomastia. Their line of work involved holding a long round rod under the axilla and then pressing the distal end of it firmly against a spinning metal plate. The patient underwent a superior pedicle breast reduction, with 1,800 ml of tissue removed from his right breast. Unfortunately, the patient experienced partial nipple loss. However, he was satisfied with the final result, and good symmetry was achieved. All five patients who worked in the same metal-pressing factory presented with unilateral gynecomastia and were examined in our department. Their average age was 51.4 years. All the patients had normal hormonal and biochemical status, and the results of screening for toxins and heavy metal exposure were negative. All the patients were heavy smokers. At examination, none of the patients had nipple discharge or retraction, skin changes, galactorrhea, or lymphadenopathy. Examination showed one patient with grade 4, three patients had grade 2, and one patient with grade 1 unilateral gynecomastia. The authors believe that gynecomastia may be considered an occupational risk in analogous metal-pressing factories because all the workers in this factory presented with some degree of unilateral gynecomastia. However, they emphasize that this may simply be an observational phenomenon without a true cause and effect relationship.
Feng, Yi; Hai, Yong; Zhao, Sheng; Zang, Lei
2016-10-01
The main treatment for congenital scoliosis is posterior hemivertebra resection with bilateral transpedicular fixation. Reports describing posterior unilateral intervertebral fusion and transpedicular screw fixation are rare, with no long-term follow-up results, especially in older children. Retrospective analysis of the long-term outcomes of unilateral fusion and fixation after hemivertebra resection for congenital scoliosis. From April 2004 to May 2012, 19 consecutive cases (12 males; age range 2.3-13.4 years) of congenital scoliosis treated by hemivertebra resection with posterior unilateral or bilateral exposure and unilateral intervertebral fusion with transpedicular screw instrumentation alone were investigated retrospectively. All cases were followed-up for at least 3 years. The mean Cobb angle of the segmental scoliosis was improved from 34.8 to 13.4° (correction rate 61.5 %). The mean Cobb angle of the segmental kyphosis was improved from 23.5 to 5.8° (correction rate 75.3 %). The mean correction rates of compensatory cranial and caudal curves were 46.1 and 54.5 %, respectively. 11 patients (57.8 %) exhibited continuous segmental curve improvement during the follow-up. One pedicle fracture and one instrumentation failure were recorded. Unilateral transpedicular screw fixation provides satisfactory correction of the spinal deformity in both very young and older children. Unilateral intervertebral fusion and transpedicular fixation represents an advisable alternative method for the correction of congenital scoliosis and has advantages of reduced trauma, less surgery time and lower expense. Furthermore, the non-fused concave side offers the opportunity for correction of subsequent spine deformity.
Unilateral laparoscopic ovariectomy in a red fox (Vulpes vulpes) with an ovarian cyst.
Lee, Seung Y; Jung, Dong H; Park, Se J; Seek, Seong H; Yang, Jeong J; Lee, Jae W; Lee, Bae K; Lee, Hee C; Yeon, Seong C
2014-09-01
Unilateral laparoscopic ovariectomy was attempted in a red fox (Vulpes vulpes) with an ovarian cyst through single portal access. The ovarian cyst was resistant to conservative therapy using gonadotropin-releasing hormone. A 10-mm laparoscope with an operating channel was introduced into the abdomen via a 12-mm umbilical portal. The left ovary and cyst (34.1 x 30.8 mm) were fixed to the left abdominal wall by a transabdominal suspension suture. The ovarian pedicles and ligaments were progressively cauterized and transected with a multifunction bipolar electrocoagulation forceps. The resected cystic ovary was exteriorized through the umbilical portal site. The surgical time was 42 min, and no intra- and postoperative complications were encountered. Two months after the surgery mating was observed, and the fox gave birth to three healthy cubs 56 days after the mating. This is the first report of using laparoscopy in the red fox with an ovarian cyst.
Rieger, Bernhard; Jiang, Hongzhen; Ruess, Daniel; Reinshagen, Clemens; Molcanyi, Marek; Zivcak, Jozef; Tong, Huaiyu; Schackert, Gabriele
2017-12-01
First description of MIS-VLIF, a minimally invasive lumbar stabilization, to evaluate its safety and feasibility in patients suffering from weak bony conditions (lumbar spondylodiscitis and/or osteoporosis). After informed consent, 12 patients suffering from lumbar spondylodiscitis underwent single level MIS-VLIF. Eight of them had a manifest osteoporosis, either. Pre- and postoperative clinical status was documented using numeric rating scale (NRS) for leg and back pain. In all cases, the optimal height for the cage was preoperatively determined using software-based range of motion and sagittal balance analysis. CT scans were obtained to evaluate correct placement of the construct and to verify fusion after 6 months. Since 2013, 12 patients with lumbar pyogenic spondylodiscitis underwent MIS-VLIF. Mean surgery time was 169 ± 28 min and average blood loss was less than 400 ml. Postoperative CT scans showed correct placement of the implants. Eleven patients showed considerable postoperative improvement in clinical scores. In one patient, we observed screw loosening. After documented bony fusion in the CT scan, the fixation system was removed in two cases to achieve lower material load. The load-bearing trajectories (vectors) of MIS-VLIF are different from those of conventional coaxial pedicle screw implantation. The dorsally converging construct combines the heads of the dorsoventral pedicle screws with laminar pedicle screws following cortical bone structures within a small approach. In case of lumbar spondylodiscitis and/or osteoporosis, MIS-VLIF relies on cortical bony structures for all screw vectors and the construct does not depend on conventional coaxial pedicle screws in the presence of inflamed, weak, cancellous or osteoporotic bone. MIS-VLIF allows full 360° lumbar fusion including cage implantation via a small, unilateral dorsal midline approach.
Virtual estimates of fastening strength for pedicle screw implantation procedures
NASA Astrophysics Data System (ADS)
Linte, Cristian A.; Camp, Jon J.; Augustine, Kurt E.; Huddleston, Paul M.; Robb, Richard A.; Holmes, David R.
2014-03-01
Traditional 2D images provide limited use for accurate planning of spine interventions, mainly due to the complex 3D anatomy of the spine and close proximity of nerve bundles and vascular structures that must be avoided during the procedure. Our previously developed clinician-friendly platform for spine surgery planning takes advantage of 3D pre-operative images, to enable oblique reformatting and 3D rendering of individual or multiple vertebrae, interactive templating, and placement of virtual pedicle implants. Here we extend the capabilities of the planning platform and demonstrate how the virtual templating approach not only assists with the selection of the optimal implant size and trajectory, but can also be augmented to provide surrogate estimates of the fastening strength of the implanted pedicle screws based on implant dimension and bone mineral density of the displaced bone substrate. According to the failure theories, each screw withstands a maximum holding power that is directly proportional to the screw diameter (D), the length of the in-bone segm,ent of the screw (L), and the density (i.e., bone mineral density) of the pedicle body. In this application, voxel intensity is used as a surrogate measure of the bone mineral density (BMD) of the pedicle body segment displaced by the screw. We conducted an initial assessment of the developed platform using retrospective pre- and post-operative clinical 3D CT data from four patients who underwent spine surgery, consisting of a total of 26 pedicle screws implanted in the lumbar spine. The Fastening Strength of the planned implants was directly assessed by estimating the intensity - area product across the pedicle volume displaced by the virtually implanted screw. For post-operative assessment, each vertebra was registered to its homologous counterpart in the pre-operative image using an intensity-based rigid registration followed by manual adjustment. Following registration, the Fastening Strength was computed for each displaced bone segment. According to our preliminary clinical study, a comparison between Fastening Strength, displaced bone volume and mean voxel intensity showed similar results (p < 0.1) between the virtually templated plans and the post-operative outcome following the traditional clinical approach. This study has demonstrated the feasibility of the platform in providing estimates the pedicle screw fastening strength via virtual implantation, given the intrinsic vertebral geometry and bone mineral density, enabling the selection of the optimal implant dimension adn trajectory for improved strength.
Spanio di Spilimbergo, Stefano; Nordera, Paolo; Mardini, Samir; Castiglione, Giusy; Chim, Harvey; Pinna, Vittore; Brunello, Massimo; Cusino, Claudio; Roberto, Squaquara; Baciliero, Ugo
2017-02-01
In the past 130 years, the temporalis muscle flap has been used for a variety of different indications. In this age of microsurgery and perforator flaps, the temporalis muscle flap still has many useful applications for craniofacial reconstruction. Three hundred sixty-six temporalis muscle flaps were performed in a single center between 1978 and 2012. The authors divided the cases into two series-before and after 1994-because, after 1994, they started to perform free flap reconstructions, and indications for reconstruction with a temporalis muscle flap were changed RESULTS:: In the series after 1994, flaps were most commonly used for reconstruction of defects in the maxilla, mandible, and oropharynx, in addition to facial reanimation and filling of orbital defects. Complications included total flap necrosis (1.6 percent) and partial flap necrosis (10.7 percent). The rate of material extrusion at the donor site decreased after porous polyethylene was uniformly used for reconstruction from 17.1 to 7.9 percent. The pedicled temporalis muscle flap continues to have many applications in craniofacial reconstruction. With increasing use of free flaps, the authors' indications for the pedicled temporalis muscle flap are now restricted to (1) orbital filling for congenital or acquired anophthalmia; (2) filling of unilateral maxillectomy defects; and (3) facial reanimation in selected cases of facial nerve palsy. Therapeutic, IV.
Wu, Liza C; Iteld, Lawrence; Song, David H
2008-06-01
Autologous breast reconstruction with the transverse rectus abdominis musculocutaneous (TRAM) flap is traditionally based on either the superior epigastric vessels (pedicled) or the deep inferior system (free). In the overweight and obese population, both techniques have been shown to have increased complications of the reconstructed breast. Another alternative is supercharging the flap by anastamosing the deep inferior epigastric vessels to either the internal mammary or thoracodorsal systems. We present a single surgeon's experience with unilateral TRAM reconstructions supercharged to either the thoracodorsal vessels, the internal mammary system, or in one case, perforator vessels in overweight and obese patients. Nineteen consecutive overweight or obese patients underwent delayed or immediate, unilateral autologous breast reconstruction with supercharged TRAM flaps between November 2000 and November 2004. The patients ranged in age from 28 to 66 years (average 49) and had an average body mass index (BMI) of 29.5 (24.9-38.3). Twelve patients had a BMI between 25 and 29.9 kg/m2; 7 patients had BMI > or =30 kg/m2. Left-sided reconstructions were 13; right-sided reconstructions were 6. Supercharging was performed by anastamosing the deep inferior epigastric artery and vein to the thoracodorsal vessels, internal mammary vessels, or perforator vessels. Follow-up ranged from 6 to 54 months. There was a qualitative increase in blood flow measured by audible Doppler signals in all patients after the arterial and venous anastamoses. There were no cases of partial or complete flap loss. One patient had a hematoma and subsequently developed minor fat necrosis. One patient had an infection of the reconstructed breast. There were no donor site complications. Supercharging the TRAM flap by means of microvascular augmentation of the deep inferior epigastric vessels provides a safe and effective breast reconstruction in the overweight and obese population with no additional morbidity.
Reddy, Aileni Amarender; Kumar, P. Anoop; Sailaja, Sistla; Chakravarthy, Yshs
2015-01-01
Soft tissue deficiencies and defects around dental implants have been observed frequently. Soft-tissue defects after implant procedures originate from the process of modelling of periimplant mucosa and often cause aesthetic disharmony, food debris accumulation and soft tissue shrinkage. Periimplant mucogingival surgery focuses on creating an optimum band of keratinized tissue resulting in soft tissue architecture similar to the gingiva around natural teeth. A 23-year-old male reported to the Department of Periodontology with a complaint of gum soreness, foul smell and food accumulation at a site where a 3.75 x 11.5mm implant was placed previously. On clinical examination, fenestration of tissue above the cover screw was observed and there appeared to be a keratinized tissue of 1mm surrounding the implant. The case was managed by use of a rotated double-pedicle flap during second-stage implant surgery to correct the soft-tissue fenestration defect and to obtain a keratinized periimplant soft tissue. A periosteal bed was prepared by giving a horizontal incision at the mucogingival junction to a depth of 4 mm. Two split-thickness keratinized pedicles were dissected from the mesial and distal interproximal tissues near the implant. After rotation, both the pedicles were sutured to each other mid-buccally and the pedicles were rigidly immobilized with sutures. At 1 month, there was a 3mm band of stable and firm keratinized tissue over the underlying tissues. The procedure resulted in an aesthetic improvement due to enhanced soft tissue architecture and optimum integration between the peri-implant soft tissue and the final prosthesis. PMID:26816998
Biomechanical Evaluation of the CD HORIZON Spire Z Spinal System With Pedicle and Facet Fixation.
Godzik, Jakub; Kalb, Samuel; Martinez-Del-Campo, Eduardo; Newcomb, Anna G U S; Singh, Vaneet; Walker, Corey T; Chang, Steve W; Kelly, Brian P; Crawford, Neil R
2016-08-01
Human cadaveric biomechanical study. The aim of this study was to evaluate the biomechanics of lumbar motion segments instrumented with the CD HORIZON Spire Z plate system (Spire Z), a posterior supplemental fixation spinous process plate, alone and with additional fixation systems. Plates and pedicle screw/rod and facet screw implants are adjuncts to fusion. The plate limits motion, improving segmental stability and the fusion microenvironment. However, the degree to which the plate contributes to overall stability when used alone or in conjunction with additional instrumentation has not been described. Standard nondestructive flexibility tests were performed in 7 L2-L5 human cadaveric spines. Spinal stability was determined as mean range of motion (ROM) in flexion/extension, lateral bending, and axial rotation. Paired comparisons were made between five conditions: (1) intact/control; (2) Spire Z; (3) Spire Z with unilateral pedicle screw/rod system (Spire Z+UPS); (4) Spire Z with unilateral facet screw system (Spire Z+UFS); and (5) Spire Z with bilateral facet screw system (Spire Z+BFS). Stiffness and ROM data were compared using one-way analysis of variance, followed by repeated-measures Holm-Šidák tests. Spire Z was most effective in limiting flexion (20% of normal) and extension (24% of normal), but less effective in reducing lateral bending and axial rotation. In lateral bending, Spire Z+BFS and Spire Z+UPS constructs were not significantly different and demonstrated greater ROM reduction compared with Spire Z+UFS and Spire Z (P < 0.001). Spire Z+BFS demonstrated greatest stiffness in axial rotation compared with Spire Z+UPS (P = 0.025), Spire Z+UFS (P = 0.001), and Spire Z (P < 0.001). Spire Z+UPS was not significantly different from Spire Z+UFS (P = 0.21), and superior to Spire Z (P = 0.013). The Spire Z spinous process plate provides excellent immediate fixation, particularly for flexion and extension. While the hybrid Spire Z+BFS screw construct afforded the greatest stability, Spire Z+UPS demonstrated considerable promise. N/A.
Liu, Da; Zhang, Yi; Lei, Wei; Wang, Cai-ru; Xie, Qing-yun; Liao, Dong-fa; Jiang, Kai; Zhou, Jin-song; Zhang, Bo; Pan, Xian-ming
2014-04-01
Expansive pedicle screw (EPS) and polymethylmethacrylate-augmented pedicle screw (PMMA-PS) were inserted in sheep vertebrae in vitro and were evaluated by performing biomechanical tests, radiographic examinations and histological observations. The objective of the study was to compare the biomechanical and interfacial performances of EPS and PMMA-PS in sheep lumbar vertebrae in vitro. It is a great challenge for orthopedic surgeons performing transpedicular fixation in the osteoporotic spine. It was reported that either the EPS or PMMA-PS could increase the screw stability. However, there are no studies comparing the 2 kinds of screws especially in primary spinal instrumentation. A total of 60 sheep lumbar vertebrae were randomly divided into 3 groups. A pilot hole was made in advance in all samples using the same method. Thereafter, the conventional pedicle screw (CPS) was inserted directly into the pilot hole in the CPS group; the hole in PMMA-PS group was first filled with polymethylmethacrylate (PMMA; 1.0 mL) and then inserted with CPS; and the EPS was inserted directly into the vertebrae in EPS group. After a period of 24 hours, biomechanical tests were performed to evaluate screw stability, and x-ray examination, micro-computerized tomography analysis, and histologic observation were performed to evaluate the interface between screw and bone. Compared with the stability of CPS, those of EPS and PMMA-PS were significantly enhanced. However, no significant differences were detected between the stabilities of EPS and PMMA-PS. The PMMA surrounding the screw blocked direct contact between bone and screw and formed a "screw-PMMA-bone" interface in the PMMA-PS group. There was a "screw-bone" interface in both CPS and EPS groups. Nevertheless, the expanded anterior part of EPS formed a claw-like structure pressing the surrounding bone trabeculae, which made the local bone tissue more compacted and denser than that in the CPS group. EPS can enhance the screw stability as markedly as the traditional PMMA-PS in primary surgery, and EPS can form a better immediate interface between screw and bone compared with PMMA-PS. EPS also can effectively avoid thermal injury, leakage, and compression caused by PMMA. A great feasibility was proved in this study to perform comparisons between the 2 kinds of pedicle screws in osteoporotic sheep vertebrae in vivo in the further research. In conclusion, we propose that EPS has a great application potential in augmentation of screw stability in the clinic.
Treatment of a supernumerary large breast with medial pedicle reduction mammaplasty.
Cinpolat, Anı; Bektas, Gamze; Seyhan, Tamer; Ozad, Ulvan; Coskunfirat, O Koray
2013-08-01
Accessory breast tissues including nipples, areolas, and glandular tissue may develop on the chest in addition to two normal breasts. An accessory breast with a complete ductal system, areola, and nipple is termed a "supernumerary breast." Supernumerary nipples are fairly common, but complete supernumerary breasts are rare. This report describes an 18-year-old woman who presented with a complete supernumerary breast including a nipple-areola complex located on the upper outer quadrant of her left breast and causing severe breast asymmetry. She was referred to the authors for aesthetic reasons. Unilateral reduction mammaplasty was performed to remove the supernumerary breast and correct the breast asymmetry. The medial pedicle Wise technique was used for en bloc resection of the ectopic breast, including the nipple-areola complex together with the upper outer breast quadrant. The woman's postoperative course was uneventful. At 8 months after surgery, she was very satisfied with the results. Ectopic breast tissue can be treated by a variety of methods such as liposuction or excision. However, breast deformation because of a complete supernumerary breast is very rare, and research on the treatment of such patients is lacking. No reports describing surgical treatment for this condition were identified in the literature. The authors suggest that unilateral breast reduction is the most appropriate treatment, allowing excision of the accessory tissues, with the best possible cosmetic outcome. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Phan, Kevin; Ramachandran, Vignesh; Tran, Tommy M; Shah, Kevin P; Fadhil, Matthew; Lackey, Alan; Chang, Nicholas; Wu, Ai-Min; Mobbs, Ralph J
2017-12-01
Fusion of the lumbosacral spine is a common surgical procedure to address a range of spinal pathologies. Fixation in lumbar fusion has traditionally been performed using pedicle screw (PS) augmentation. However, an alternative method of screw insertion via cortical bone trajectory (CBT) has been advocated as a less invasive approach which improves initial fixation and reduces neurovascular injury. There is a paucity of robust clinical evidence to support these claims, particularly in comparison to traditional pedicle screws. This study aims to review the available evidence to assess the merits of the CBT approach. Six electronic databases were searched for original published studies which compared CBT with traditional PS and their findings reviewed. Nine comparative studies were identified through a comprehensive literature search. Studies were classified as retrospective cohort, prospective cohort or case control studies with medium quality as assessed by the GRADE criteria. The available literature is not cohesive regarding outcomes and complications of CBT versus PT procedures. Most studies found no difference in operative time, but reported less blood loss during CBT. Radiological outcomes show no difference in slippage at one year although CBT is associated with greater bone-density compared to PT. Results for post-operative pain are inconclusive.
Mao, Ke-ya; Wang, Yan; Xiao, Song-hua; Zhang, Yong-gang; Liu, Bao-wei; Wang, Zheng; Zhang, Xi-Feng; Cui, Geng; Zhang, Xue-song; Li, Peng; Mao, Ke-zheng
2013-08-01
To investigate the feasibility of minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) using hybrid internal fixation of pedicle screws and a translaminar facet screw for recurrent lumbar disc herniation. From January 2010 to December 2011, 16 recurrent lumbar disc herniation patients, 10 male and 6 female patients with an average age of 45 years (35-68 years) were treated with unilateral incision MIS-TLIF through working channel. After decompression, interbody fusion and fixation using unilateral pedicle screws, a translaminar facet screw was inserted from the same incision through spinous process and laminar to the other side facet joint. The results of perioperative parameters, radiographic images and clinical outcomes were assessed. The repeated measure analysis of variance was applied in the scores of visual analogue scale (VAS) and Oswestry disablity index (ODI). All patients MIS-TLIF were accomplished under working channel including decompression, interbody fusion and hybrid fixation without any neural complication. The average operative time was (148 ± 75) minutes, the average operative blood loss was (186 ± 226) ml, the average postoperative ambulation time was (32 ± 15) hours, and the average hospitalization time was (6 ± 4) days. The average length of incision was (29 ± 4) mm, and the average length of translaminar facets screw was (52 ± 6) mm. The mean follow-up was 16.5 months with a range of 12-24 months. The postoperative X-ray and CT images showed good position of the hybrid internal fixation, and all facets screws penetrate through facets joint. The significant improvement could be found in back pain VAS, leg pain VAS and ODI scores between preoperative 1 day and postoperative follow-up at all time-points (back pain VAS:F = 52.845, P = 0.000;leg pain VAS:F = 113.480, P = 0.000;ODI:F = 36.665, P = 0.000). Recurrent lumbar disc herniation could be treated with MIS-TLIF using hybrid fixation through unilateral incision, and the advantage including less invasion and quickly recovery.
Lefèvre, M; Sarfati, B; Honart, J-F; Alkashnam, H; Rimareix, F; Leymarie, N; Kolb, F
2017-02-01
The musculocutaneous tensor fascia latae flap was one of the first free flaps described. It is possible to harvest a flap with the same skin paddle, vascularized by a septo-cutaneous perforator running through the tensor fascia lata muscle septum and coming from the ascending branch of the lateral circumflex femoral artery. The DIEP is currently the workhorse of autologous breast reconstruction, but there are some contraindications. The septo-cutaneous tensor fascia latae perforator flap may be an alternative for women with lateral upper thigh lipodystrophy. Between 2010 and 2014, three flaps have been performed in two patients for delayed breast reconstruction (one case of unilateral reconstruction, and one bilateral). Perforators were identified by preoperative angiography. The intervention was performed in a two-team approach, in only one operative position. Perforators were located in the horizontal axis of the upper rim of the pubis bone. One perforator artery was dissected for each flap. The mean caliber of the pedicle was 2.8mm, and the mean length was 6.4cm. The operative time was 240minutes for unilateral flap, 375minutes for bilateral flap. There was no case of total or partial necrosis, or complications on the donor site. Cosmetic results were considered satisfying by patients and surgeons with the reconstructed breast as well as the donor site. Septo-cutaneous fascia lata perforator flap is an attractive flap for breast reconstruction in patients with DIEP contraindication and lateral upper thigh lipodystrophy. It has many advantages: easy to harvest, length and calibre of the pedicle, double team approach, only one operating position, quality of reconstruction. It is necessary to carry out a larger series of cases to study the complication rate in the donor site. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Desktop-based computer-assisted orthopedic training system for spinal surgery.
Rambani, Rohit; Ward, James; Viant, Warren
2014-01-01
Simulation and surgical training has moved on since its inception during the end of the last century. The trainees are getting more exposed to computers and laboratory training in different subspecialties. More needs to be done in orthopedic simulation in spinal surgery. To develop a training system for pedicle screw fixation and validate its effectiveness in a cohort of junior orthopedic trainees. Fully simulated computer-navigated training system is used to train junior orthopedic trainees perform pedicle screw insertion in the lumbar spine. Real patient computed tomography scans are used to produce the real-time fluoroscopic images of the lumbar spine. The training system was developed to simulate pedicle screw insertion in the lumbar spine. A total of 12 orthopedic senior house officers performed pedicle screw insertion in the lumbar spine before and after the training on training system. The results were assessed based on the scoring system, which included the amount of time taken, accuracy of pedicle screw insertion, and the number of exposures requested to complete the procedure. The result shows a significant improvement in amount of time taken, accuracy of fixation, and the number of exposures after the training on simulator system. This was statistically significant using paired Student t test (p < 0.05). Fully simulated computer-navigated training system is an efficient training tool for young orthopedic trainees. This system can be used to augment training in the operating room, and trainees acquire their skills in the comfort of their study room or in the training room in the hospital. The system has the potential to be used in various other orthopedic procedures for learning of technical skills in a manner aimed at ensuring a smooth escalation in task complexity leading to the better performance of procedures in the operating theater. Copyright © 2014 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Ito, Manabu; Abumi, Kuniyoshi; Kotani, Yoshihisa; Takahata, Masahiko; Hojo, Yoshihiro; Minami, Akio
2010-01-01
The number of reports describing osteoporotic vertebral fracture has increased as the number of elderly people has grown. Anterior decompression and fusion alone for the treatment of vertebral collapse is not easy for patients with comorbid medical problems and severe bone fragility. The purpose of the present study was to evaluate the efficacy of one-stage posterior instrumentation surgery for the treatment of osteoporotic vertebral collapse with neurological deficits. A consecutive series of 21 patients who sustained osteoporotic vertebral collapse with neurological deficits were managed with posterior decompression and short-segmental pedicle screw instrumentation augmented with ultra-high molecular weight polyethylene (UHMWP) cables with or without vertebroplasty using calcium phosphate cement. The mean follow-up was 42 months. All patients showed neurologic recovery. Segmental kyphotic angle at the instrumented level was significantly improved from an average preoperative kyphosis of 22.8–14.7 at a final follow-up. Spinal canal occupation was significantly reduced from an average before surgery of 40.4–19.1% at the final follow-up. Two patients experienced loosening of pedicle screws and three patients developed subsequent vertebral compression fractures within adjacent segments. However, these patients were effectively treated in a conservative fashion without any additional surgery. Our results indicated that one-stage posterior instrumentation surgery augmented with UHMWP cables could provide significant neurological improvement in the treatment of osteoporotic vertebral collapse. PMID:20157741
Sudo, Hideki; Ito, Manabu; Abumi, Kuniyoshi; Kotani, Yoshihisa; Takahata, Masahiko; Hojo, Yoshihiro; Minami, Akio
2010-06-01
The number of reports describing osteoporotic vertebral fracture has increased as the number of elderly people has grown. Anterior decompression and fusion alone for the treatment of vertebral collapse is not easy for patients with comorbid medical problems and severe bone fragility. The purpose of the present study was to evaluate the efficacy of one-stage posterior instrumentation surgery for the treatment of osteoporotic vertebral collapse with neurological deficits. A consecutive series of 21 patients who sustained osteoporotic vertebral collapse with neurological deficits were managed with posterior decompression and short-segmental pedicle screw instrumentation augmented with ultra-high molecular weight polyethylene (UHMWP) cables with or without vertebroplasty using calcium phosphate cement. The mean follow-up was 42 months. All patients showed neurologic recovery. Segmental kyphotic angle at the instrumented level was significantly improved from an average preoperative kyphosis of 22.8-14.7 at a final follow-up. Spinal canal occupation was significantly reduced from an average before surgery of 40.4-19.1% at the final follow-up. Two patients experienced loosening of pedicle screws and three patients developed subsequent vertebral compression fractures within adjacent segments. However, these patients were effectively treated in a conservative fashion without any additional surgery. Our results indicated that one-stage posterior instrumentation surgery augmented with UHMWP cables could provide significant neurological improvement in the treatment of osteoporotic vertebral collapse.
[Cement augmentation on the spine : Biomechanical considerations].
Kolb, J P; Weiser, L; Kueny, R A; Huber, G; Rueger, J M; Lehmann, W
2015-09-01
Vertebral compression fractures are the most common osteoporotic fractures. Since the introduction of vertebroplasty and screw augmentation, the management of osteoporotic fractures has changed significantly. The biomechanical characteristics of the risk of adjacent fractures and novel treatment modalities for osteoporotic vertebral fractures, including pure cement augmentation by vertebroplasty, and cement augmentation of screws for posterior instrumentation, are explored. Eighteen human osteoporotic lumbar spines (L1-5) adjacent to vertebral bodies after vertebroplasty were tested in a servo-hydraulic machine. As augmentation compounds we used standard cement and a modified low-strength cement. Different anchoring pedicle screws were tested with and without cement augmentation in another cohort of human specimens with a simple pull-out test and a fatigue test that better reflects physiological conditions. Cement augmentation in the osteoporotic spine leads to greater biomechanical stability. However, change in vertebral stiffness resulted in alterations with the risk of adjacent fractures. By using a less firm cement compound, the risk of adjacent fractures is significantly reduced. Both screw augmentation techniques resulted in a significant increase in the withdrawal force compared with the group without cement. Augmentation using perforated screws showed the highest stability in the fatigue test. The augmentation of cement leads to a significant change in the biomechanical properties. Differences in the stability of adjacent vertebral bodies increase the risk of adjacent fractures, which could be mitigated by a modified cement compound with reduced strength. Screws that were specifically designed for cement application displayed greatest stability in the fatigue test.
Liu, Fubing; Jiang, Chun
2016-01-01
The aim of this study was to evaluate the risk factors between ipsilateral and contralateral reherniation and to compare the effectiveness of miniopen transforaminal lumbar interbody fusion (TLIF) with unilateral fixation for each group. From November 2007 to December 2014, clinical and radiographic data of each group (ipsilateral or contralateral reherniation) were collected and compared. Functional assessment (Visual Analog Scale (VAS) score and Japanese Orthopaedic Association (JOA)) and radiographic evaluation (fusion status, disc height, lumbar lordosis (LL), and functional spine unit (FSU) angle) were applied to compare surgical effect for each group preoperatively and at final followup. MacNab questionnaire was applied to further evaluate the satisfactory rate after the discectomy and fusion. No difference except pain-free interval was found between ipsilateral and contralateral groups. There was a significant difference in operative time between two groups. No differences were found in clinical and radiographic data for assessment of surgical effect between two groups. The satisfactory rate was decreasing in both groups with time passing after discectomy. Difference in pain-free interval may be a distinction for ipsilateral and contralateral reherniation. Miniopen TLIF with unilateral pedicle screw fixation can be a recommendable way for single level reherniation regardless of ipsilateral or contralateral reherniation. PMID:27885358
Aneja, Vikas; Raval, Rushik; Bansal, Anupam; Kumawat, Vinod; Kaur, Jasleen; Shaikh, Ahemer Arif
2016-10-01
Temporomandibular Joint (TMJ) ankylosis is a situation in which the mandibular condyle is fused to the glenoid fossa by bone or fibrous tissue. The management of TMJ ankylosis has a complicated chore and it is challenging for the maxillofacial surgeon because of technical hitches and high rate of re-ankylosis. Interpositional gap arthroplasty is one of the modalities for its management. A range of inter-positional materials have been used to avert recurrence after gap arthroplasty in TMJ ankylosis. The aim of this series was to evaluate the effectiveness of the temporomyofacial flap in the treatment of TMJ ankylosis as an interpositional gap arthroplasty. A total of 10 cases with unilateral TMJ ankylosis were treated by interpositional gap arthroplasty by pedicled temporalis myofacial flap and evaluated with a follow-up of 6 months to 5 years (Mean 3.3 years) for the functional stability of TMJ. All the patients were successfully treated. There were no signs of recurrence in any patients up to last follow up visit. The result showed that temporalis myofascial flap is a preferable choice for inter-positional gap arthroplasty which proves its versatility as an inter-positional material.
Aneja, Vikas; Bansal, Anupam; Kumawat, Vinod; Kaur, Jasleen; Shaikh, Ahemer Arif
2016-01-01
Temporomandibular Joint (TMJ) ankylosis is a situation in which the mandibular condyle is fused to the glenoid fossa by bone or fibrous tissue. The management of TMJ ankylosis has a complicated chore and it is challenging for the maxillofacial surgeon because of technical hitches and high rate of re-ankylosis. Interpositional gap arthroplasty is one of the modalities for its management. A range of inter-positional materials have been used to avert recurrence after gap arthroplasty in TMJ ankylosis. The aim of this series was to evaluate the effectiveness of the temporomyofacial flap in the treatment of TMJ ankylosis as an interpositional gap arthroplasty. A total of 10 cases with unilateral TMJ ankylosis were treated by interpositional gap arthroplasty by pedicled temporalis myofacial flap and evaluated with a follow-up of 6 months to 5 years (Mean 3.3 years) for the functional stability of TMJ. All the patients were successfully treated. There were no signs of recurrence in any patients up to last follow up visit. The result showed that temporalis myofascial flap is a preferable choice for inter-positional gap arthroplasty which proves its versatility as an inter-positional material. PMID:27891496
Sachdeva, Virender; Mittal, Vaibhev; Gupta, Varun; Gunturu, Rekha; Kekunnaya, Ramesh; Chandrasekharan, Anjali; Chabblani, Preeti Patil; Rao, Harsha L.
2016-01-01
Purpose: To compare the efficacy of combined occlusion and atropine therapy (COAT) and augmented part-time patching for the treatment of unilateral refractory/residual amblyopia. Methodology: This retrospective study evaluated children between 4 and 11 years with refractory/residual amblyopia who were treated with either additional atropine (COAT group) or increased hours of patching (augmented group). Data were collected on improvement in best-corrected visual acuity (BCVA; logarithm of the minimum angle of resolution [logMAR] units) at each follow-up visit. Results: There were 19 children in the COAT group and 17 children in the augmented group. The baseline BCVA of the amblyopic eye was 0.79 ± 0.36 logMAR in the COAT group and 0.72 ± 0.26 logMAR in augmented group. Children were statistically significantly younger in the COAT group (6.4 ± 2.2 years) compared to the augmented group (8.6 ± 3.3 years, P = 0.02). The mean duration of follow-up was statistically significantly longer in the augmented group (20.2 COAT group; 13.9 months augmented group) (P = 0.03). Compliance was similar in both groups. LogMAR BCVA (adjusted for difference in age and baseline BCVA) was statistically significantly better in the COAT group (0.56 ± 0.04) compared to the augmented group (0.80 ± 0.04) at 3 months (P = 0.000); 6 months (COAT group, 0.50 ± 0.04 vs. augmented group, 0.74 ± 0.04; P = 0.04) and at 1 year (COAT group, 0.42 ± 0.04 vs. augmented group, 0.67 ± 0.04, P = 0.000). There was statistically significantly greater improvement in logMAR BCVA at 6 months in COAT group (0.26 ± 0.15) compared to the augmented group (0.02 ± 0.14), (P = 0.0002). Age, gender, pretreatment BCVA, duration of follow-up, or compliance to patching did not affect improvement in BCVA. Conclusions: COAT may result in greater improvement in BCVA than augmented part-time patching in children with unilateral residual/refractory amblyopia. PMID:27162453
Sachdeva, Virender; Mittal, Vaibhev; Gupta, Varun; Gunturu, Rekha; Kekunnaya, Ramesh; Chandrasekharan, Anjali; Chabblani, Preeti Patil; Rao, Harsha L
2016-01-01
To compare the efficacy of combined occlusion and atropine therapy (COAT) and augmented part-time patching for the treatment of unilateral refractory/residual amblyopia. This retrospective study evaluated children between 4 and 11 years with refractory/residual amblyopia who were treated with either additional atropine (COAT group) or increased hours of patching (augmented group). Data were collected on improvement in best-corrected visual acuity (BCVA; logarithm of the minimum angle of resolution [logMAR] units) at each follow-up visit. There were 19 children in the COAT group and 17 children in the augmented group. The baseline BCVA of the amblyopic eye was 0.79 ± 0.36 logMAR in the COAT group and 0.72 ± 0.26 logMAR in augmented group. Children were statistically significantly younger in the COAT group (6.4 ± 2.2 years) compared to the augmented group (8.6 ± 3.3 years, P = 0.02). The mean duration of follow-up was statistically significantly longer in the augmented group (20.2 COAT group; 13.9 months augmented group) (P = 0.03). Compliance was similar in both groups. LogMAR BCVA (adjusted for difference in age and baseline BCVA) was statistically significantly better in the COAT group (0.56 ± 0.04) compared to the augmented group (0.80 ± 0.04) at 3 months (P = 0.000); 6 months (COAT group, 0.50 ± 0.04 vs. augmented group, 0.74 ± 0.04; P = 0.04) and at 1 year (COAT group, 0.42 ± 0.04 vs. augmented group, 0.67 ± 0.04, P = 0.000). There was statistically significantly greater improvement in logMAR BCVA at 6 months in COAT group (0.26 ± 0.15) compared to the augmented group (0.02 ± 0.14), (P = 0.0002). Age, gender, pretreatment BCVA, duration of follow-up, or compliance to patching did not affect improvement in BCVA. COAT may result in greater improvement in BCVA than augmented part-time patching in children with unilateral residual/refractory amblyopia.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Masala, Salvatore, E-mail: salva.masala@tiscali.it; Tarantino, Umberto; Nano, Giovanni, E-mail: gionano@gmail.com
Purpose. The purpose of this study was to evaluate the effectiveness of a new pedicle screw-based posterior dynamic stabilization device PDS Percudyn System Trade-Mark-Sign Anchor and Stabilizer (Interventional Spine Inc., Irvine, CA) as alternative minimally invasive treatment for patients with lumbar spine stenosis. Methods. Twenty-four consecutive patients (8 women, 16 men; mean age 61.8 yr) with lumbar spinal stenosis underwent implantation of the minimally invasive pedicle screw-based device for posterior dynamic stabilization. Inclusion criteria were lumbar stenosis without signs of instability, resistant to conservative treatment, and eligible to traditional surgical posterior decompression. Results. Twenty patients (83 %) progressively improved duringmore » the 1-year follow-up. Four (17 %) patients did not show any improvement and opted for surgical posterior decompression. For both responder and nonresponder patients, no device-related complications were reported. Conclusions. Minimally invasive PDS Percudyn System Trade-Mark-Sign has effectively improved the clinical setting of 83 % of highly selected patients treated, delaying the need for traditional surgical therapy.« less
Syrimpeis, Vasileios; Vitsas, Vasileios; Korovessis, Panagiotis
2014-03-01
Context Hemangiomas are the commonest benign tumors of the spine. Most occur in the thoracolumbar spine and the majority are asymptomatic. Rarely, hemangiomas cause symptoms through epidural expansion of the involved vertebra, resulting in spinal canal stenosis, spontaneous epidural hemorrhage, and pathological burst fracture. Findings We report a rare case of a 73-year-old woman, who had been treated for two months for degenerative neurogenic claudication. On admission, magnetic resonance imaging and computed tomographic scans revealed a hemangioma of the third lumbar vertebra protruding to the epidural space producing lateral spinal stenosis and ipsilateral nerve root compression. The patient underwent successful right hemilaminectomy for decompression of the nerve root, balloon kyphoplasty with poly-methyl methacrylate (PMMA) and pedicle screw segmental stabilization. Postoperative course was uneventful. Conclusion In the elderly, this rare presentation of spinal stenosis due to hemangiomas may be encountered. Decompression and vertebral augmentation by means balloon kyphoplasty with PMMA plus segmental pedicle screw fixation is recommended.
Syrimpeis, Vasileios; Vitsas, Vasileios; Korovessis, Panagiotis
2014-01-01
Context Hemangiomas are the commonest benign tumors of the spine. Most occur in the thoracolumbar spine and the majority are asymptomatic. Rarely, hemangiomas cause symptoms through epidural expansion of the involved vertebra, resulting in spinal canal stenosis, spontaneous epidural hemorrhage, and pathological burst fracture. Findings We report a rare case of a 73-year-old woman, who had been treated for two months for degenerative neurogenic claudication. On admission, magnetic resonance imaging and computed tomographic scans revealed a hemangioma of the third lumbar vertebra protruding to the epidural space producing lateral spinal stenosis and ipsilateral nerve root compression. The patient underwent successful right hemilaminectomy for decompression of the nerve root, balloon kyphoplasty with poly-methyl methacrylate (PMMA) and pedicle screw segmental stabilization. Postoperative course was uneventful. Conclusion In the elderly, this rare presentation of spinal stenosis due to hemangiomas may be encountered. Decompression and vertebral augmentation by means balloon kyphoplasty with PMMA plus segmental pedicle screw fixation is recommended. PMID:24090267
Inferior Pedicle Autoaugmentation Mastopexy After Breast Implant Removal
Frey, Hans Peter; Hasse, Frank Michael; Hasselberg, Jens
2010-01-01
Background A new method of autoaugmentation mammaplasty is presented to correct ptosis and to increase the projection and volume of the breast in patients who would like a reposition augmentation mammaplasty after breast implant removal but do not want a new implant. Methods Between 1999 and 2007, a total of 27 patients (age = 54 ± 7.3 years) underwent mammaplasty using an inferior-based flap of deepithelialized subcutaneous and breast tissue modularized to its pedicle which was inserted beneath a superior pedicle used for correction of ptosis and to increase the projection and apparent volume of the breast. Results The results confirmed that autoaugmentation mammaplasty of the breast following removal of the implant yields longstanding results. It corrects ptosis and increases the projection and apparent volume of the breast when mastopexy is planned without use of a new implant. Twelve months after surgery the degree of descent of the inframammary fold generally parallels that of the nipple. The mean level of the inframammary fold was below the mean level of the nipple. Postoperatively, the optimum distance had been largely achieved. Conclusion The advantages of the technique presented here are that it minimizes the skin scar in cases using vertical mammaplasty techniques and optimizes the breast shape after breast implant removal in patients who do not want a new implant. PMID:20174800
Gan, Cheng; Fan, Jincai; Liu, Liqiang; Tian, Jia; Jiao, Hu; Chen, Wenlin; Fu, Siqi; Feng, Suyun
2013-11-01
The expanded forehead flap, using temporal pedicles, has been employed extensively in facial reconstruction. To overcome the disadvantages of the traditional dual temporal pedicles, such as the limited transfer range and the short length of the flap, the distal supercharging technique can be applied to lengthen the flap and extend the transfer range, especially in the cases with a past temporal burn injury. This article aims to present an application of the distal supercharged expanded forehead flap procedure for hemi-facial reconstruction and discuss the haemodynamics of the expanded forehead flap. The tissue expander implantation and the following forehead tissue expansion were performed regularly. When the forehead skin expansion was completed, an expanded forehead flap was created and transferred to the damaged facial area with one distal temporal vessel pedicle that was anastomosed with facial vessels in a supercharged way. All patients were analysed retrospectively. From September 2009 to September 2011, eight male patients and one female patient were treated using this method. Their flaps size ranged from 20 cm × 8 cm to 30 cm × 11 cm and no flap loss occurred. Patients came in for follow-ups 9-16 months after the procedures. All the patients were satisfied with the results. The supercharging expanded forehead flap procedure can provide reliable flap vascularity due to its elastic transferring abilities. By using a distal supercharging technique, we can lengthen and widen the flap to tailor it to the defect, while also minimising the donor defect in the patients with a past temporal injury. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Laser-assisted indocyanine green angiography: a critical appraisal.
Wu, Cindy; Kim, Sendia; Halvorson, Eric G
2013-05-01
Laser-assisted indocyanine green angiography (ICG-A) has been promoted to assess perfusion of random skin, pedicled, and free flaps. Few studies address its potential limitations. Thirty-seven patients who underwent reconstructive procedures with ICG-A were studied retrospectively to determine the correlation between clinical findings and ICG-A. Indocyanine green angiography underestimated perfusion when areas of less than or equal to 25% uptake were not debrided and remained perfused. Indocyanine green angiography overestimated perfusion when areas with greater than 25% uptake developed necrosis. Of 14 random skin flaps, ICG-A underestimated perfusion in 14% and overestimated in 14%. In 16 patients undergoing perforator flap breast reconstruction, ICG-A correlated with computed tomographic angiogram (CTA) in 85%. Indocyanine green angiography underestimated perfusion in 7% and overestimated in 7%. In 8/11 patients undergoing fasciocutaneous flaps, ICG-A aided in donor site selection. In 3/6 ALT flaps, a better unilateral blush was found that correlated with Doppler. In all 3, a dominant perforator was found. In 11 patients, there was a 9% underestimation of flap perfusion. In 3 pedicled flaps, there was a 66% underestimation and 33% overestimation of perfusion. Indocyanine green angiography often confirmed our clinical/radiologic findings in abdominal perforator and fasciocutaneous flaps. It tended to underestimate perfusion in pedicle and skin flaps. When clinical examination was obvious, ICG-A rendered clear-cut findings. When clinical examination was equivocal, ICG-A tended to provide ambiguous findings, demonstrating that a distinct cutoff point does not exists for every patient or flap. Indocyanine green angiography is a promising but expensive technology that would benefit from standardization. Further research is needed before ICG-A can become a reliable tool for surgeons.
Biomechanical demands on posterior fusion instrumentation during lordosis restoration procedures.
Kuo, Calvin C; Martin, Audrey; Telles, Connor; Leasure, Jeremi; Iezza, Alex; Ames, Christopher; Kondrashov, Dimitriy
2016-09-01
OBJECTIVE The goal of this study was to investigate the forces placed on posterior fusion instrumentation by 3 commonly used intraoperative techniques to restore lumbar lordosis: 1) cantilever bending; 2) in situ bending; and 3) compression and/or distraction of screws along posterior fusion rods. METHODS Five cadaveric torsos were instrumented with pedicle screws at the L1-5 levels. Specimens underwent each of the 3 lordosis restoration procedures. The pedicle screw pullout force was monitored in real time via strain gauges that were mounted unilaterally at each level. The degree of correction was noted through fluoroscopic imaging. The peak loads experienced on the screws during surgery, total demand on instrumentation, and resting loads after corrective maneuvers were measured. RESULTS A mean overall lordotic correction of 10.9 ± 4.7° was achieved. No statistically significant difference in lordotic correction was observed between restoration procedures. In situ bending imparted the largest loads intraoperatively with an average of 1060 ± 599.9 N, followed by compression/distraction (971 ± 534.1 N) and cantilever bending (705 ± 413.0 N). In situ bending produced the largest total demand and postoperative loads at L-1 (1879 ± 1064.1 and 487 ± 118.8 N, respectively), which were statistically higher than cantilever bending and compression/distraction (786 ± 272.1 and 138 ± 99.2 N, respectively). CONCLUSIONS In situ bending resulted in the highest mechanical demand on posterior lumbar instrumentation, as well as the largest postoperative loads at L-1. These results suggest that the forces generated with in situ bending indicate a greater chance of intraoperative instrumentation failure and postoperative proximal pedicle screw pullout when compared with cantilever bending and/or compression/distraction options. The results are aimed at optimizing correction and fusion strategies in lordosis restoration cases.
Mantell, Matthew; Cyriac, Mathew; Haines, Colin M; Gudipally, Manasa; O'Brien, Joseph R
2016-01-01
Insufficient biomechanical data exist from comparisons of the stability of expandable lateral cages with that of static transforaminal lumbar interbody fusion (TLIF) cages. The purpose of this biomechanical study was to compare the relative rigidity of L4-5 expandable lateral interbody constructs with or without additive pedicle screw fixation with that of L4-5 static TLIF cages in a novel cadaveric spondylolisthesis model. Eight human cadaver spines were used in this study. A spondylolisthesis model was created at the L4-5 level by creating 2 injuries. First, in each cadaver, a nucleotomy from 2 channels through the anterior side was created. Second, the cartilage of the facet joint was burred down to create a gap of 4 mm. Light-emitting-diode tracking markers were placed at L-3, L-4, L-5, and S-1. Specimens were tested in the following scenarios: intact model, bilateral pedicle screws, expandable lateral 18-mm-wide cage (alone, with unilateral pedicle screws [UPSs], and with bilateral pedicle screws [BPSs]), expandable lateral 22-mm-wide cage (alone, with UPSs, and with BPSs), and TLIF (alone, with UPSs, and with BPSs). Four of the spines were tested with the expandable lateral cages (18-mm cage followed by the 22-mm cage), and 4 of the spines were tested with the TLIF construct. All these constructs were tested in flexion-extension, axial rotation, and lateral bending. The TLIF-alone construct was significantly less stable than the 18- and 22-mm-wide lateral lumbar interbody fusion (LLIF) constructs and the TLIF constructs with either UPSs or BPSs. The LLIF constructs alone were significantly less stable than the TLIF construct with BPSs. However, there was no significant difference between the 18-mm LLIF construct with UPSs and the TLIF construct with BPSs in any of the loading modes. Expandable lateral cages with UPSs provide stability equivalent to that of a TLIF construct with BPSs in a degenerative spondylolisthesis model.
Feng, Yun; Yang, Dazhang; Liu, Dandan; Chen, Jian; Bi, Qingling; Luo, Keqiang
2014-08-01
To explore the application of immediate recurrent laryngeal nerve reconstruction in the treatment of thyroid cancer invading the recurrent laryngeal nerve. Ten patients with thyroid cancer invading unilateral recurrent laryngeal nerve underwent radical surgery and immediate recurrent laryngeal nerve reconstruction. The reconstructive surgical approach included recurrent laryngeal nerve decompression surgery, end-to-end anastomosis of the recurrent laryngeal nerve, anastomosis of ansa cervicalis nerve to the recurrent laryngeal nerve, and nerve-muscle pedicle (NMP) technique. Among the ten patients, one underwent nerve decompression, one underwent end-to-end anastomosis of the recurrent laryngeal nerve, seven had anastomosis of ansa cervicalis to recurrent laryngeal nerve, and one case had anastomosis of ansa cervicalis to recurrent laryngeal nerve combined with nerve-muscle pedicle (NMP) technique. The effect of surgery was evaluated by videolaryngoscopy, maximum phonation time (MPT), phonation efficiency index (PEI) and voice assessment. T-test was used in the statistical analysis. All of the 10 patients had no complications including tumor recurrence and hypoparathyroidism after the surgery. Their hoarseness symptoms were improved, and the patients returned to normal or near-normal voice. Postoperative videolaryngoscopy showed that paralyzed vocal cord returned to normal muscle tone and volume, and the vocal cord vibration and mucosal wave were symmetric and the patients got good glottal closure. The pre- and post-operative maximum phone times of the patients were (4.52 ± 0.89) s and (11.91 ± 1.87) s, respectively (P < 0.01). The pre- and post-operative phonation efficiency indices were (1.37 ± 0.43) s/L and (4.02 ± 1.33) s/L, respectively (P < 0.05). In patients with thyroid cancer invading unilateral recurrent laryngeal nerve, immediate recurrent laryngeal nerve reconstruction following radical surgery of thyroid cancer can effectively achieve recovery in phonation function and improve the quality of life of the patients.
Angiographic delay: a viable alternative to surgical delay.
Aboutanos, Sharline Z; Spinos, Efstathios; Blanchet, Nadia P
2012-06-01
Selective embolization of the inferior epigastric arteries can serve as a method for transverse rectus abdominis musculocutaneous (TRAM) flap delay. The purpose of this study was to determine whether delay by selective arterial embolization is comparable to traditionally surgically delayed TRAM flaps as reported in the literature, in terms of skin and fat necrosis, and to examine whether certain risk factors play a role in TRAM flap fat necrosis despite angiographic delay. Retrospective chart review was performed for 88 consecutive patients who underwent unilateral TRAM flap breast reconstruction after selective embolization of bilateral inferior epigastric arteries. Between 1997 and 2009, 88 pedicled TRAM flaps were performed for breast reconstruction in women with a mean age of 49.7 years. No patients had flap skin necrosis or total flap loss. In all, 13.6% patients had TRAM flap fat necrosis. Two patients in the TRAM fat necrosis group (16.7%) had a positive history of smoking, which was a statistically significant risk factor for necrosis (P = 0.048). Outcomes of pedicled TRAM flaps delayed by selective arterial embolization are comparable to historical controls of those delayed by traditional surgical means (ligation of artery and vein) and better than nondelayed flaps. Smoking remains a significant risk factor for TRAM flap fat necrosis despite the benefit of delay.
Pülzl, Petra; Huemer, Georg M; Schoeller, Thomas
2015-02-01
Capsular contracture is a common complication associated with implant-based breast reconstruction and augmentation leading to pain, displacement, and rupture. After capsulectomy and implant exchange, the problem often reappears. We performed 52 deepithelialized free transverse musculocutaneous gracilis (TMG) flaps in 33 patients for tertiary breast reconstruction or augmentation of small- and medium-sized breasts. The indications for implant removal were unnatural feel and emotion of their breasts with foreign body feel, asymmetry, pain, and sensation of cold. Anyway, most of the patients did not have a severe capsular contracture deformity. The TMG flap is formed into a cone shape by bringing the tips of the ellipse together. Depending on the contralateral breast, the muscle can also be shaped in an S-form to get more projection if needed. The operating time for unilateral TMG flap breast reconstruction or augmentation was on average 3 hours and for bilateral procedure 5 hours. One patient had a secondary revision of the donor site due to disruption of the normal gluteal fold. Eighty percent of the unilateral TMG flap reconstructions had a lipofilling procedure afterward to correct small irregularities or asymmetry. The advantages of the TMG flap such as short harvesting time, inconspicuous donor site, and the possibility of having a natural breast shape make it our first choice to treat capsular contracture after breast reconstruction and augmentation.
Reductive Augmentation of the Breast.
Chasan, Paul E
2018-06-01
Although breast reduction surgery plays an invaluable role in the correction of macromastia, it almost always results in a breast lacking in upper pole fullness and/or roundness. We present a technique of breast reduction combined with augmentation termed "reductive augmentation" to solve this problem. The technique is also extremely useful for correcting breast asymmetry, as well as revising significant pseudoptosis in the patient who has previously undergone breast augmentation with or without mastopexy. An evolution of techniques has been used to create a breast with more upper pole fullness and anterior projection in those patients desiring a more round, higher-profile appearance. Reductive augmentation is a one-stage procedure in which a breast augmentation is immediately followed by a modified superomedial pedicle breast reduction. Often, the excision of breast tissue is greater than would normally be performed with breast reduction alone. Thirty-five patients underwent reductive augmentation, of which 12 were primary surgeries and 23 were revisions. There was an average tissue removal of 255 and 227 g, respectively, per breast for the primary and revision groups. Six of the reductive augmentations were performed for gross asymmetry. Fourteen patients had a previous mastopexy, and 3 patients had a previous breast reduction. The average follow-up was 26 months. Reductive augmentation is an effective one-stage method for achieving a more round-appearing breast with upper pole fullness both in primary breast reduction candidates and in revisionary breast surgery. This technique can also be applied to those patients with significant asymmetry. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Ohtsuka, Toshiya; Ninomiya, Mikio; Nonaka, Takahiro
2009-07-01
: A pedicled prepericardial fat flap was created to augment the pericardial cavity and applied for patients undergoing coronary artery bypass grafting. The efficacy and durability of this method were investigated. : Between July 2005 and November 2008, the present technique was applied for consecutive 245 patients (165 men and 80 women, aged 67 ± 8.3 years) undergoing isolated coronary artery bypass grafting in which 240 (98.0%) were off-pump cases. The left and/or right internal thoracic artery and the gastroepiploic artery were used in 244 and 160 patients, respectively, and the saphenous vein and the radial artery were used in 51 and 10 patients, respectively. Ninety-seven (40.0%) patients had been diabetic, 18 (7.3%) had had chronic renal failure, and three were redo cases. The prepericardial soft tissue, involving the pedicled thymic gland, was dissected en bloc and sewn with pericardiotomies to wrap the heart and the grafts. Angiography or three-dimensional computed tomography was used to assess the intrapericardial pathways of each graft and a long-term durability of the fat pad. : Early angiography or three-dimensional computed tomography proved that the graft pathways were unaffected by the encasements. Resternotomies in two patients and sternal treatments for infectious dehiscence in two patients were safely achievable. Five-year postoperative computed tomography showed the intact fat pad in the retrosternal space. : The present technique can encase the heart not the least jeopardizing each pathway of the grafts, and the durable fat pad functions protectively when the sternotomy is either reopened or infected.
Effect of injection augmentation on need for framework surgery in unilateral vocal fold paralysis.
Francis, David O; Williamson, Kelly; Hovis, Kristen; Gelbard, Alexander; Merati, Albert L; Penson, David F; Netterville, James L; Garrett, C Gaelyn
2016-01-01
To determine whether injection augmentation reduces the likelihood of ultimately needing definitive framework surgery in unilateral vocal fold paralysis (UVFP) patients. Retrospective cohort study. All patients diagnosed with UVFP (2008-2012) at the academic center were identified. The time from symptom onset to presentation to either community otolaryngologist and/or academic center, as well as any directed treatment(s), were recorded. Stepwise, multivariate logistic regression analysis was used to determine whether injection augmentation independently affected odds of needing definitive, framework surgery among patients who were seen within 9 months of symptom onset and had not undergone any prior rehabilitative procedures. Cohort consisted of 633 patients (55% female, 80% Caucasian, median age 60 years) with UVFP. The majority of etiologies were either surgery (48%) or idiopathic (37%). Duration to presentation at community otolaryngologist was shorter than to the academic center (median 2 vs. 6 months). Overall, less than half of UVFP patients had any operation (46%). Multivariate logistic regression found that earlier injection augmentation did not affect odds of ultimately undergoing framework surgery (odds ratio 1.13; confidence interval, 0.92-1.40; P = 0.23). Nearly half of UVFP patients do not require any rehabilitative procedure. When indicated, early injection augmentation is effective at temporarily alleviating associated symptoms but does not reduce likelihood of needing a definitive framework operation in patients with UVFP. Understanding practice patterns and fostering early detection and treatment may improve quality of life in this patient population. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.
Techy, Fernando; Mageswaran, Prasath; Colbrunn, Robb W; Bonner, Tara F; McLain, Robert F
2013-05-01
Segmental fixation improves fusion rates and promotes patient mobility by controlling instability after lumbar surgery. Efforts to obtain stability using less invasive techniques have lead to the advent of new implants and constructs. A new interspinous fixation device (ISD) has been introduced as a minimally invasive method of stabilizing two adjacent interspinous processes by augmenting an interbody cage in transforaminal interbody fusion. The ISD is intended to replace the standard pedicle screw instrumentation used for posterior fixation. The purpose of this study is to compare the rigidity of these implant systems when supplementing an interbody cage as used in transforaminal lumbar interbody fusion. An in vitro human cadaveric biomechanical study. Seven human cadaver spines (T12 to the sacrum) were mounted in a custom-designed testing apparatus, for biomechanical testing using a multiaxial robotic system. A comparison of segmental stiffness was carried out among five conditions: intact spine control; interbody spacer (IBS), alone; interbody cage with ISD; IBS, ISD, and unilateral pedicle screws (unilat); and IBS, with bilateral pedicle screws (bilat). An industrial robot (KUKA, GmbH, Augsburg, Germany) applied a pure moment (±5 Nm) in flexion-extension (FE), lateral bending (LB), and axial rotation (AR) through an anchor to the T12 vertebral body. The relative vertebral motion was captured using an optoelectronic camera system (Optotrak; Northern Digital, Inc., Waterloo, Ontario, Canada). The load sensor and the camera were synchronized. Maximum rotation was measured at each level and compared with the intact control. Implant constructs were compared with the control and with each other. A statistical analysis was performed using analysis of variance. A comparison between the intact spine and the IBS group showed no significant difference in the range of motion (ROM) in FE, LB, or AR for the operated level, L3-L4. After implantation of the ISD to augment the IBS, there was a significant decrease in the ROM of 74% in FE (p<.001) but no significant change in the ROM in LB and AR. The unilat construct significantly reduced the ROM by 77% compared with FE control (p<.001) and by 55% (p=.002) and 42% (p=.04) in LB and AR, respectively, compared with control. The bilat construct reduced the ROM in FE by 77% (p<.001), LB by 77% (p=.001), and AR by 65% (p=.001) when compared with the control spine. There was no statistically significant difference in the ROM in FE among the stand-alone ISD, unilat, and bilat constructs. However, in both LB and AR, the unilat and the bilat constructs were significantly stiffer (reduction in the ROM) than the ISD and the IBS combination. The ISD stability in LB and AR was not different from the intact control with no instrumentation at all. There was no statistical difference between the stability of the unilat and the bilat constructs in any direction. However, LB and AR in the unilat group produced a mean rotation of 3.83°±3.30° and 2.33°±1.33°, respectively, compared with the bilat construct that limited motion to 1.96°±1.46° and 1.39°±0.73°. There was a trend suggesting that the bilat construct was the most rigid construct. In FE, the ISD can provide lumbar stability comparable with Bilat instrumentation. It provides minimal rigidity in LB and AR when used alone to stabilize the segment after an IBS placement. The unilat and the more typical bilat screw constructs were shown to provide similar levels of stability in all directions after an IBS placement, though the bilat construct showed a trend toward improved stiffness overall. Copyright © 2013 Elsevier Inc. All rights reserved.
Reliable harvest of a dorsal scapular artery perforator flap by augmenting its perfusion.
Kim, So-Young; Lee, Kyeong-Tae; Mun, Goo-Hyun
2016-02-01
Despite confirmation of a reliable perforasome in the dorsal scapular artery in an anatomic study, a true perforator flap has not been recommended in previous clinical studies because of concerns regarding insufficient perfusion in the distal region. In this report, we present two cases of reconstruction for occipital defects caused by tumor extirpation using pedicled dorsal scapular artery perforator flaps without a muscle component. To secure the perfusion of the dorsal scapular artery perforator flap, inclusion of an additional perforator was attempted for perfusion augmentation. The second dorsal scapular artery perforator was harvested in one case. In an additional case, the sixth dorsal intercostal artery perforator with a branch that directly connected with the dorsal scapular artery within the trapezius muscle was additionally harvested. The flaps survived without any perfusion-related complications, including tip necrosis, and no donor site morbidities were observed. We suggest that a perfusion augmented dorsal scapular artery perforator flap by harvesting multiple perforators could be a safe and useful alternative for reconstructive surgery of head and neck defects. © 2014 Wiley Periodicals, Inc.
Kanna, P Rishimugesh; Shetty, Ajoy Prasad; Rajasekaran, S
2011-07-15
Prospective analysis of computed tomographic images of 376 normal pediatric cervical pedicles. To study the normal cervical pedicle morphometrics, the changes in pedicle morphology with skeletal growth, and the possibility of pedicle screw insertion. Although the usage of cervical pedicle screws in adults has become established, the feasibility of its application in children has not been studied. There are no in vivo studies that define the normal pediatric cervical pedicle morphometrics and its changes with growth and development of the child. A total of 376 normal pediatric cervical spine pedicles of 30 children (mean age = 6.7 ± 3.9 years) were analyzed for pedicle width (PW), pedicle height (PH), pedicle length (PL), pedicle axis length (PAL), transverse pedicle angle (TPA), and sagittal pedicle angle (SPA). The study population was categorized into three age groups (A: <5 years, B: 5-10 years, and C >10 years). The mean values of these parameters in the different age groups and the possibility of application cervical pedicle screws were studied. RESULTS.: The mean PW was lowest in the C3 vertebra and increased distally to be widest at C7. Sixty percent of C3 pedicles had a width less than 4 mm making screw passage risky and unsafe. With growth, the PW increased at all levels but this increase was significant only up to the age of 10 years. More than 75% of adult pedicle dimensions were achieved by 5 years of age. The mean PL at all levels remained the same with no significant increase with growth. However, the PAL showed continuous increase with growth similar to PW. The PAL also showed an increase from C3 to C7. The PH was always more than the PW at any level. Mild insignificant asymmetry was present between the right and left side pedicles in all values. With growth, there was a gradual increase in PW, PH, and PAL but was mainly before the age of 10 years. Majority of C3 pedicles were thin making screw fixation unsafe. However, at all other levels, the pedicle morphometrics per se were adequate and do not restrict safe application of 3-mm cervical pedicle screw.
Biomechanical analysis comparing three C1-C2 transarticular screw salvaging fixation techniques.
Elgafy, Hossein; Potluri, Tejaswy; Goel, Vijay K; Foster, Scott; Faizan, Ahmad; Kulkarni, Nikhil
2010-02-15
This is an in vitro biomechanical study. To compare the biomechanical stability of the 3 C1-C2 transarticular screw salvaging fixation techniques. Stabilization of the atlantoaxial complex is a challenging procedure because of its complicated anatomy. Many posterior stabilization techniques of the atlantoaxial complex have been developed with C1-C2 transarticular screw fixation been the current gold standard. The drawback of using the transarticular screws is that it has a potential risk of vertebral artery injury due to a high riding transverse foramen of C2 vertebra, and screw malposition. In such cases, it is not recommended to proceed with inserting the contralateral transarticular screw and the surgeon should find an alternative to fix the contralateral side. Many studies are available comparing different atlantoaxial stabilization techniques, but none of them compared the techniques to fix the contralateral side while using the transarticular screw on one side. The current options are C1 lateral mass screw and short C2 pedicle screw or C1 lateral mass screw and C2 intralaminar screw, or C1-C2 sublaminar wire. Nine fresh human cervical spines with intact ligaments (C0-C4) were subjected to pure moments in the 6 loading directions. The resulting spatial orientations of the vertebrae were recorded using an Optotrak 3-dimensional Motion Measurement System. Measurements were made sequentially for the intact spine after creating type II odontoid fracture and after stabilization with unilateral transarticular screw placement across C1-C2 (TS) supplemented with 1 of the 3 transarticular salvaging techniques on the contralateral side; C1 lateral mass screw and C2 pedicle screw (TS+C1LMS+C2PS), C1 lateral mass and C2 intralaminar screw (TS+C1LMS+C2ILS), or sublaminar wire (TS + wire). The data indicated that all the 3 stabilization techniques significantly decreased motion when compared to intact in all the loading cases (left/right lateral bending, left/right axial rotation, flexion) except extension. All the 3 instrumented specimens were equally stable in extension/flexion and lateral bending modes. TS+C1LMS+C2PS was equivalent to TS+C1LMS+C2ILS (P > 0.05) and superior to TS + wire in axial rotation (P < 0.05). Also, TS+C1LMS+C2ILS was superior to TS + wire in axial rotation (P < 0.05). Fixation of atlantoaxial complex using unilateral transarticular screw supplemented with contralateral C1 lateral mass and C2 intralaminar screws is biomechanically equivalent to C1 lateral mass and C2 pedicle screws and both are biomechanically superior to C1-C2 sublaminar wire in axial rotation.
Alaraj, Ali; Charbel, Fady T; Birk, Daniel; Tobin, Matthew; Tobin, Mathew; Luciano, Cristian; Banerjee, Pat P; Rizzi, Silvio; Sorenson, Jeff; Foley, Kevin; Slavin, Konstantin; Roitberg, Ben
2013-01-01
Recent studies have shown that mental script-based rehearsal and simulation-based training improve the transfer of surgical skills in various medical disciplines. Despite significant advances in technology and intraoperative techniques over the last several decades, surgical skills training on neurosurgical operations still carries significant risk of serious morbidity or mortality. Potentially avoidable technical errors are well recognized as contributing to poor surgical outcome. Surgical education is undergoing overwhelming change, as a result of the reduction of work hours and current trends focusing on patient safety and linking reimbursement with clinical outcomes. Thus, there is a need for adjunctive means for neurosurgical training, which is a recent advancement in simulation technology. ImmersiveTouch is an augmented reality system that integrates a haptic device and a high-resolution stereoscopic display. This simulation platform uses multiple sensory modalities, re-creating many of the environmental cues experienced during an actual procedure. Modules available include ventriculostomy, bone drilling, percutaneous trigeminal rhizotomy, and simulated spinal modules such as pedicle screw placement, vertebroplasty, and lumbar puncture. We present our experience with the development of such augmented reality neurosurgical modules and the feedback from neurosurgical residents.
Ebraheim, Nabil A; Liu, Jiayong; Ramineni, Satheesh K; Liu, Xiaochen; Xie, Joe; Hartman, Ryan G; Goel, Vijay K
2009-11-01
Many investigators have conducted studies to determine the biomechanics, causes, complications and treatment of unilateral facet joint dislocation in the cervical spine. However, there is no quantitative data available on morphological changes in the intervertebral foramen of the cervical spine following unilateral facet joint dislocation. These data are important to understand the cause of neurological compromise following unilateral facet joint dislocation. Eight embalmed human cadaver cervical spine specimens ranging from level C1-T1 were used. The nerve roots of these specimens at C5-C6 level were marked by wrapping a 0.12mm diameter wire around them. Unilateral facet dislocation at C5-C6 level was simulated by serially sectioning the corresponding ligamentous structures. A CT scan of the specimens was obtained before and after the dislocation was simulated. A sagittal plane through the centre of the pedicle and facet joint was constructed and used for measurement. The height and area of the intervertebral foramen, the facet joint space, nerve root diameter and area, and vertebral alignment both before and after dislocation were evaluated. The intervertebral foramen area changed from 50.72+/-0.88mm(2) to 67.82+/-4.77mm(2) on the non-dislocated side and from 41.39+/-1.11mm(2) to 113.77+/-5.65mm(2) on the dislocated side. The foraminal heights changed from 9.02+/-0.30mm to 10.52+/-0.50mm on the non-dislocated side and 10.43+/-0.50mm to 17.04+/-0.96mm on the dislocated side. The facet space area in the sagittal plane changed from 6.80+/-0.80mm(2) to 40.02+/-1.40mm(2) on the non-dislocated side. The C-5 anterior displacement showed a great change from 0mm to 5.40+/-0.24mm on the non-dislocated side and from 0mm to 3.42+/-0.20mm on the dislocated side. Neither of the nerve roots on either side showed a significant change in size. The lack of change in nerve root area indicates that the associated nerve injury with unilateral facet joint dislocation is probably due to distraction rather than due to direct nerve root compression.
Long-Term Patency of Twisted Vascular Pedicles in Perforator-Based Propeller Flaps.
Jakubietz, Rafael G; Nickel, Aljoscha; Neshkova, Iva; Schmidt, Karsten; Gilbert, Fabian; Meffert, Rainer H; Jakubietz, Michael G
2017-10-01
Propeller flaps require torsion of the vascular pedicle of up to 180 degrees. Contrary to free flaps, where the relevance of an intact vascular pedicle has been documented, little is known regarding twisted pedicles of propeller flaps. As secondary surgeries requiring undermining of the flap are common in the extremities, knowledge regarding the necessity to protect the pedicle is relevant. The aim of this study was a long-term evaluation of the patency of vascular pedicle of propeller flaps. In a retrospective clinical study, 22 patients who underwent soft-tissue reconstruction with a propeller flap were evaluated after 43 months. A Doppler probe was used to locate and evaluate the patency of the vascular pedicle of the flap. The flaps were used in the lower extremity in 19 cases, on the trunk in 3 cases. All flaps had healed. In all patients, an intact vascular pedicle could be found. Flap size, source vessel, or infection could therefore not be linked to an increased risk of pedicle loss. The vascular pedicle of propeller flaps remains patent in the long term. This allows reelevation and undermining of the flap. We therefore recommend protecting the pedicle in all secondary cases to prevent later flap loss.
Wang, Jeremy C; Haid, Regis W; Miller, Jay S; Robinson, James C
2006-02-01
The authors present the early clinical results obtained in patients who underwent SPIRE spinous process plate fixation following anterior lumbar interbody fusion (ALIF). Between May 2003 and January 2005, 32 patients underwent titanium cage and bone morphogenetic protein-augmented ALIF and subsequent SPIRE (21 cases) or bilateral pedicle screw (BPS; 11 cases) fixation. Pedicle screws were implanted using either the open approach (three cases) or using a tubular retractor (eight cases). Patients' charts were reviewed for operative time, estimated blood loss (EBL), hospital length of stay (LOS), and evidence of pseudarthrosis or hardware failure. In SPIRE plate-treated patients, the median EBL (75 ml) was lower than in BPS-treated patients (open BPS [150 ml]; tubular BPS [125 ml]). The median operative time in SPIRE plate-treated patients was also shorter (164 minutes compared with 239 and 250 minutes in the open and tubular BPS, respectively). The median LOS was 3 days for both the SPIRE and tubular BPS groups, but 4 days in the open BPS group. There were no instances of major surgery-induced complication, pseudarthrosis, or hardware failure during mean follow-up periods of 5.5, 7.2, and 4.9 months in the SPIRE, open PS, and tubular BPS groups, respectively. The SPIRE plate is easy to implant and is associated with minimal operative risk. Compared with BPS/rod constructs, SPIRE plate fixation leads to less EBL and shorter operative time, without an increase in the rate of pseudarthrosis. Hospital LOS was also shorter in SPIRE plate-treated patients, which is consistent with the goals of minimal access spinal technologies.
Chan, Chris Yin Wei; Kwan, Mun Keong; Saw, Lim Beng
2010-01-01
The objective of this cadaveric study is to determine the safety and outcome of thoracic pedicle screw placement in Asians using the funnel technique. Pedicle screws have superior biomechanical as well as clinical data when compared to other methods of instrumentation. However, misplacement in the thoracic spine can result in major neurological implications. There is great variability of the thoracic pedicle morphometry between the Western and the Asian population. The feasibility of thoracic pedicle screw insertion in Asians has not been fully elucidated yet. A pre-insertion radiograph was performed and surgeons were blinded to the morphometry of the thoracic pedicles. 240 pedicle screws were inserted in ten Asian cadavers from T1 to T12 using the funnel technique. 5.0 mm screws were used from T1 to T6 while 6.0 mm screws were used from T7 to T12. Perforations were detected by direct visualization via a wide laminectomy. The narrowest pedicles are found between T3 and T6. T5 pedicle width is smallest measuring 4.1 +/- 1.3 mm. There were 24 (10.0%) Grade 1 perforations and only 1 (0.4%) Grade 2 perforation. Grade 2 or worse perforation is considered significant perforation which would threaten the neural structures. There were twice as many lateral and inferior perforations compared to medial perforations. 48.0% of the perforations occurred at T1, T2 and T3 pedicles. Pedicle fracture occurred in 10.4% of pedicles. Intra-operatively, the absence of funnel was found in 24.5% of pedicles. In conclusion, thoracic pedicle screws using 5.0 mm at T1-T6 and 6.0 mm at T7-T12 can be inserted safely in Asian cadavers using the funnel technique despite having smaller thoracic pedicle morphometry.
Khan, Umar Daraz
2010-02-01
Infections after augmentation mammoplasty are not uncommon, and prophylactic antibiotics are routinely administered to minimize infection. However, there is paucity of information on the relationship between the length of prophylaxis cover and its benefits in primary augmentation mammoplasty. A retrospective analysis of different antibiotic cover regimens, their effectiveness in preventing infections, and the management of infection in established cases is reviewed. A retrospective chart analysis of periprosthetic infections in primary augmentation mammoplasties performed over the past 10 years was conducted. Periprosthetic infection was determined by the presence of pain, swelling, redness, and discharge. Each breast was taken as an individual unit in 1,628 patients, and data for 3,256 breasts were analyzed. The patients had their augmentation in the partial submuscular plane (214 breasts in 107 patients), the subglandular plane (1,548 breasts in 774 patients), and the muscle-splitting biplane (1,494 breasts in 747 patients). All the patients had soft round cohesive gel silicone implants. Of the 3,256 implants, 3,218 were textured, and 38 were smooth surfaced. The patients received antibiotics as a single intravenous dose of cephalosporin (474 breasts in 237 patients), a single intravenous dose plus an oral dose for 24 h (344 breasts in 172 patients), or a single intravenous dose plus an oral course for 5 days (2,438 breasts in 1,219 patients). Infection was recorded as superficial (e.g., wound breakdown, stitch extrusion, stitch abscess) or deep (periprosthetic). The patients with established periprosthetic infections, determined clinically by the presence of pain, discharge, swelling, and redness of the breasts, were managed either conservatively using antibiotics, passive wound drainage, and healing of the wound with secondary intention or by explantation and replacement after 3 to 4 months. In selected cases of periprosthetic infection, the implants were removed after a course of antibiotics and negative swab cultures. The cavity was washed thoroughly with betadine and saline, and new implants were simultaneously reimplanted. The incidence of infection was lowest with a single perioperative dose of intravenous antibiotic compared with a combination of intravenous and oral antibiotics. Superficial infection was seen in 38 breasts (all unilateral), with an incidence of 1.2%, and periprosthetic infection was observed in 17 breasts (13 unilateral and 2 bilateral), giving an infection incidence of 0.52% (p = 0.002). In patients with a single intravenous dose of antibiotic, superficial and periprosthetic infection was seen in four breasts (0.8%) and no breasts, respectively. The difference was not significant (p = 0.13). The patients receiving a single intravenous antibiotic and a 24-h oral antibiotic had superficial and periprosthetic infection rates of 2.3% (8 breasts) and 0.3% (1 breast), respectively, and the difference between the two sub-groups was significantly higher (p = 0.04). The patients receiving an intravenous antibiotic and 5 days of oral antibiotics had superficial and periprosthetic infection rates of 1.1% (26 breasts) and 0.65% (14 breasts), respectively. The difference between the two subgroups was not significant (p = 0.09). Of the 17 periprosthetic infections in 15 patients (13 unilateral and 2 bilateral), 11 breasts (1 bilateral and 9 unilateral) were treated conservatively using antibiotics, passive drainage, and wound healing with secondary intention. Capsular contracture developed in two of the conservatively treated breasts, requiring capsulotomies with change of implants. Of the six periprosthetic infections in six patients, requiring surgical intervention, two implants were treated using explantation with immediate replacement after a course of antibiotics and a negative culture, and two implants were explanted followed by reimplantation later. One patient had both implants removed after unilateral infection, and no reimplantation was performed. One patient had a bilateral infection. In this case, one implant was explanted and the other was treated conservatively. The patient had bilateral reimplantion 6 months later, and bilateral Baker 4 capsular contracture developed in both breasts within 6 months. No other complications were seen in the patients who underwent surgery. A single dose of intravenous antibiotic is adequate for prophylaxis in breast augmentation surgery, and the extra duration of antibiotic cover does not result in reduced superficial or periprosthetic infections. Infection can be managed in more than one way depending on the nature, degree, and extent of infection.
Simple New Screw Insertion Technique without Extraction for Broken Pedicle Screws.
Kil, Jin-Sang; Park, Jong-Tae
2018-05-01
Spinal transpedicular screw fixation is widely performed. Broken pedicle screw rates range from 3%-7.1%. Several techniques have been described for extraction of broken pedicle screws. However, most of these techniques require special instruments. We describe a simple, modified technique for management of broken pedicle screws without extraction. No special instruments or drilling in an adjacent pedicle are required. We used a high-speed air drill with a round burr. With C-arm fluoroscopy guidance, the distal fragment of a broken pedicle screw was palpated using free-hand technique through the screw entry hole. A high-speed air drill with a round burr (not a diamond burr) was inserted through the hole. Drilling began slowly and continued until enough space was obtained for new screw insertion. Using this space, we performed new pedicle screw fixation medially alongside the distal fragment of the broken pedicle screw. We performed the insertion with a previously used entry hole and pathway in the pedicle. The same size pedicle screw was used. Three patients were treated with this modified technique. New screw insertion was successful in all cases after partial drilling of the distal broken pedicle screw fragment. There were no complications, such as screw loosening, dural tears, or root injury. We describe a simple, modified technique for management of broken pedicle screws without extraction. This technique is recommended in patients who require insertion of a new screw. Copyright © 2017. Published by Elsevier Inc.
Spiotta, Alejandro M; Miranpuri, Amrendra S; Vargas, Jan; Magarick, Jordan; Turner, Raymond D; Turk, Aquilla S; Chaudry, M Imran
2014-09-01
Endovascular embolization for tumors and vascular malformations has emerged as an important preoperative adjunct prior to resection. We describe the advantages of utilizing a recently released dual lumen balloon catheter for ethylene vinyl alcohol copolymer, also known as Onyx (ev3, Irvine, California, USA), embolization for a variety of head and neck pathologies. A retrospective review of all cases utilizing the Scepter C balloon catheter (MicroVention Inc, Tustin, California, USA) for use in balloon augmented embolization was performed over a 4 month period from October 2012 to February 2013 at the Medical University of South Carolina, Charleston, South Carolina, USA. Charts and angiographic images were reviewed. Representative cases involving diverse pathologies are summarized and illustrate the observed advantages of balloon augmented Onyx embolization with a dual lumen balloon catheter. Balloon augmented Onyx embolization utilizing a novel dual lumen balloon catheter was employed to treat both ruptured and unruptured arteriovenous malformations, intracranial dural arteriovenous fistulae, intracranial neoplasms, carotid body tumors, a thyroid mass, and an extracranial arteriovenous fistula. The dual lumen balloon catheter has several advantages for use with Onyx embolization over older devices, including more efficient proximal plug formation and enhanced navigability for placement deep within the pedicles. The balloon augmented Onyx embolization technique represents a valuable tool to add to the armamentarium of the neurointerventionalist to address a variety of head and neck lesions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Evaluation of an omental pedicle extension technique in the dog.
Ross, W E; Pardo, A D
1993-01-01
A two-step omental pedicle extension technique was performed on 10 dogs. Step 1 of the pedicle extension involved release of the dorsal leaf of the omentum from its pancreatic attachment, whereas step 2 consisted of an inverse L-shaped incision to double the length of the pedicle. The pedicle dimensions were measured and the distance reached when extended toward the hind limb, forelimb, and the muzzle recorded after each stage of the procedure. The vascular patency of the pedicle was determined by intravenous injection of fluorescein dye after the second stage of omental extension. Mean pedicle lengths were 44.5 cm with the first stage of extension and 82.0 cm after full extension. The mean width at the caudal extent of the pedicles after dorsal and full extension was 30.4 cm and 17.2 cm, respectively. Eight of the 10 pedicles were patent after full extension. The fully extended omental pedicles reached and, in most cases, extended beyond the distal extremities and the muzzle. The findings in this study suggest that the canine omentum can be extended to any part of the body without being detached from its vascular supply.
Evaluation of Titanium-Coated Pedicle Screws: In Vivo Porcine Lumbar Spine Model.
Kim, Do-Yeon; Kim, Jung-Ryul; Jang, Kyu Yun; Kim, Min Gu; Lee, Kwang-Bok
2016-07-01
Many studies have addressed the problem of loosening pedicle screws in spinal surgery, which is a serious concern. Titanium coating of medical implants (arthroplasty) is common, but few studies involving in vivo spine models have been reported. We evaluated the radiological, mechanical, and histological characteristics of titanium-coated pedicle screws compared with uncoated or hydroxyapatite-coated pedicle screws. Three different types of pedicle screws, i.e., uncoated, hydroxyapatite-coated, and titanium-coated, were implanted into the lumbar 3-4-5 levels of 9 mature miniature pigs. Radiological evaluation of loosening of pedicle screws was performed. Peak torsional extraction torque was tested in the 42 screws from 7 miniature pigs at 12 weeks postoperatively. The implant-bone interface of the remaining 12 pedicle screws from 2 miniature pigs in each group was assessed by micro-computed tomography and histologic studies. The incidence of loosening at 12 weeks postoperatively was not significantly different between the titanium-coated pedicle screw group and the other groups. The titanium-coated pedicle screw group exhibited the greatest mean extraction torsional peak torque at 12 weeks postoperatively (P < 0.05). Quantitative micro-computed tomography data were greatest in the titanium-coated pedicle screw group (P < 0.05). Histologic findings showed osteointegration with densely packed new bone formation at the screw coating-bone interface in the titanium-coated pedicle screw group. Fixation strength was greatest in the titanium-coated pedicle screw group. Osteointegration at the interface between the titanium-coated implant and bone produced prominent and firm bonding. The titanium-coated pedicle screw is a promising device for application in spinal surgery. Copyright © 2016 Elsevier Inc. All rights reserved.
Belcik, J Todd; Mott, Brian H; Xie, Aris; Zhao, Yan; Kim, Sajeevani; Lindner, Nathan J; Ammi, Azzdine; Linden, Joel M; Lindner, Jonathan R
2015-04-01
Ultrasound can increase tissue blood flow, in part, through the intravascular shear produced by oscillatory pressure fluctuations. We hypothesized that ultrasound-mediated increases in perfusion can be augmented by microbubble contrast agents that undergo ultrasound-mediated cavitation and sought to characterize the biological mediators. Contrast ultrasound perfusion imaging of hindlimb skeletal muscle and femoral artery diameter measurement were performed in nonischemic mice after unilateral 10-minute exposure to intermittent ultrasound alone (mechanical index, 0.6 or 1.3) or ultrasound with lipid microbubbles (2×10(8) IV). Studies were also performed after inhibiting shear- or pressure-dependent vasodilator pathways, and in mice with hindlimb ischemia. Ultrasound alone produced a 2-fold increase (P<0.05) in muscle perfusion regardless of ultrasound power. Ultrasound-mediated augmentation in flow was greater with microbubbles (3- and 10-fold higher than control for mechanical index 0.6 and 1.3, respectively; P<0.05), as was femoral artery dilation. Inhibition of endothelial nitric oxide synthase attenuated flow augmentation produced by ultrasound and microbubbles by 70% (P<0.01), whereas inhibition of adenosine-A2a receptors and epoxyeicosatrienoic acids had minimal effect. Limb nitric oxide production and muscle phospho-endothelial nitric oxide synthase increased in a stepwise fashion by ultrasound and ultrasound with microbubbles. In mice with unilateral hindlimb ischemia (40%-50% reduction in flow), ultrasound (mechanical index, 1.3) with microbubbles increased perfusion by 2-fold to a degree that was greater than the control nonischemic limb. Increases in muscle blood flow during high-power ultrasound are markedly amplified by the intravascular presence of microbubbles and can reverse tissue ischemia. These effects are most likely mediated by cavitation-related increases in shear and activation of endothelial nitric oxide synthase. © 2015 American Heart Association, Inc.
Belcik, J. Todd; Mott, Brian H.; Xie, Aris; Zhao, Yan; Kim, Sajeevani; Lindner, Nathan J.; Ammi, Azzdine; Linden, Joel M.; Lindner, Jonathan R.
2015-01-01
Background Ultrasound can increase tissue blood flow in part through the intravascular shear produced by oscillatory pressure fluctuations. We hypothesized that ultrasound-mediated increases in perfusion can be augmented by microbubble contrast agents that undergo ultrasound-mediated cavitation, and sought to characterize the biologic mediators. Methods and Results Contrast ultrasound perfusion imaging of hindlimb skeletal muscle and femoral artery diameter measurement were performed in non-ischemic mice after unilateral 10 min exposure to intermittent ultrasound alone (mechanical index [MI] 0.6 or 1.3) or ultrasound with lipid microbubbles (2×108 I.V.). Studies were also performed after inhibiting shear- or pressure-dependent vasodilator pathways, and in mice with hindlimb ischemia. Ultrasound alone produced a 2-fold increase (p<0.05) in muscle perfusion regardless of ultrasound power. Ultrasound-mediated augmentation in flow was greater with microbubbles (3-fold and 10-fold higher than control for MI 0.6 and 1.3, respectively; p<0.05), as was femoral artery dilation. Inhibition of endothelial nitric oxide synthase (eNOS) attenuated flow augmentation produced by ultrasound and microbubbles by 70% (p<0.01), whereas inhibition of adenosine-A2a receptors and epoxyeicosatrienoic acids had minimal effect. Limb nitric oxide (NO) production and muscle phospho-eNOS increased in a stepwise fashion by ultrasound and ultrasound with microbubbles. In mice with unilateral hindlimb ischemia (40–50% reduction in flow), ultrasound (MI 1.3) with microbubbles increased perfusion by 2-fold to a degree that was greater than the control non-ischemic limb. Conclusions Increases in muscle blood flow during high-power ultrasound are markedly amplified by the intravascular presence of microbubbles and can reverse tissue ischemia. These effects are most likely mediated by cavitation-related increases in shear and activation of eNOS. PMID:25834183
Li, Ying; Luo, Ming; Wang, Wengang; Shen, Mingkui; Xu, Genzhong; Gao, Jianbo; Xia, Lei
2017-10-01
To explore the prevalence and distribution of abnormal vertebral pedicles in scoliosis secondary to neurofibromatosis type 1 (NF1-S) and to compare the abnormal vertebrae pedicles between dystrophic and nondystrophic scoliosis. Using computed tomography images, we carefully measured 2652 vertebral pedicles from 56 patients with NF1-S with dystrophic scoliosis and 22 patients with NF1-S with nondystrophic scoliosis. Pedicle morphology was classified as follows: type A, a cancellous channel of >4 mm; type B, a cancellous channel of 2 to 4 mm; type C, a cancellous channel of <2 mm with an entirely cortical channel of ≥2 mm; type D, a cortical channel of <2 mm; or type E, absent pedicle. Types B, C, D, and E were defined as abnormal. The total prevalence of abnormal vertebral pedicles in patients with NF1-S was as high as 67%, with type B comprising 39%, type C comprising 22%, type D comprising 4%, and type E comprising 2%. A significantly greater rate of abnormal pedicles was found in dystrophic scoliosis compared with nondystrophic scoliosis (70% vs. 59%, P < 0.0001). The upper thoracic spine (87%) is the most concentrated region of abnormal pedicles compared with the lower thoracic (73%) and lumbar spine (34%). There is a significantly high prevalence of abnormal pedicles in patients with NF1-S and an increased rate of abnormal pedicles in dystrophic scoliosis compared with nondystrophic ones. The described pedicle classification system could serve as an objective tool to guide preoperative assessment. Copyright © 2017 Elsevier Inc. All rights reserved.
Pedicle screw placement in patients with variant atlas pedicle.
Zhang, Qiang-Hua; Li, Hai-Dong; Min, Ji-Kang
2016-08-01
To investigate how the anatomy of variant atlas vertebra impacts on the strategy used to place pedicle screws used to treat atlantoaxial instability. The study enrolled patients with cervical instability who had a posterior arch pedicle height <3.5 mm at the anchor point, a vertebral artery groove height <3.5 mm, or both. Pedicle screws were fitted according to the anatomy of the variant atlas vertebra. Patients were followed-up to evaluate accuracy of the screw placement and maintenance of cervical stability. A total of 28 patients were enrolled. The mean height of the atlas pedicle proximal section was >5.0 mm. For the vertebral artery groove, the height of the lateral region was significantly greater than that of the medial region. Approximately 60% of atlas vertebrae had lateral heights >3.5 mm (34 of 56). The majority of the posterior arch heights were <3.0 mm. There were no perioperative or postoperative complications observed. Pedicle screw placement in the lateral pedicle region is the safest and most reliable strategy to treat variant atlas pedicles. © The Author(s) 2016.
Bredow, Jan; Boese, C K; Werner, C M L; Siewe, J; Löhrer, L; Zarghooni, K; Eysel, P; Scheyerer, M J
2016-08-01
Pedicle screw fixation is the standard technique for the stabilization of the spine, a clinically relevant complication of which is screw loosening. This retrospective study investigates whether preoperative CT scanning can offer a predictor of screw loosening. CT-scan attenuation in 365 patients was evaluated to determine the mean bone density of each vertebral body. Screw loosening or dislocation was determined in CT scans postoperatively using the standard radiological criteria. Forty-five of 365 patients (12.3 %; 24 male, 21 female) suffered postoperative screw loosening (62 of 2038 screws) over a mean follow-up time of 50.8 months. Revision surgeries were necessary in 23 patients (6.3 %). The correlation between decreasing mean CT attenuation in Hounsfield Units (HU) and increasing patient age was significant (p < 0.001). Mean bone density was 116.3 (SD 53.5) HU in cases with screw loosening and 132.7 (SD 41.3) HU in cases in which screws remained fixed. The difference was statistically significant (p = 0.003). The determination of bone density with preoperative CT scanning can predict the risk of screw loosening and inform the decision to use cement augmentation to reduce the incidence of screw loosening.
Helgeson, Melvin D; Kang, Daniel G; Lehman, Ronald A; Dmitriev, Anton E; Luhmann, Scott J
2013-08-01
There is currently no reliable technique for intraoperative assessment of pedicle screw fixation strength and optimal screw size. Several studies have evaluated pedicle screw insertional torque (IT) and its direct correlation with pullout strength. However, there is limited clinical application with pedicle screw IT as it must be measured during screw placement and rarely causes the spine surgeon to change screw size. To date, no study has evaluated tapping IT, which precedes screw insertion, and its ability to predict pedicle screw pullout strength. The objective of this study was to investigate tapping IT and its ability to predict pedicle screw pullout strength and optimal screw size. In vitro human cadaveric biomechanical analysis. Twenty fresh-frozen human cadaveric thoracic vertebral levels were prepared and dual-energy radiographic absorptiometry scanned for bone mineral density (BMD). All specimens were osteoporotic with a mean BMD of 0.60 ± 0.07 g/cm(2). Five specimens (n=10) were used to perform a pilot study, as there were no previously established values for optimal tapping IT. Each pedicle during the pilot study was measured using a digital caliper as well as computed tomography measurements, and the optimal screw size was determined to be equal to or the first size smaller than the pedicle diameter. The optimal tap size was then selected as the tap diameter 1 mm smaller than the optimal screw size. During optimal tap size insertion, all peak tapping IT values were found to be between 2 in-lbs and 3 in-lbs. Therefore, the threshold tapping IT value for optimal pedicle screw and tap size was determined to be 2.5 in-lbs, and a comparison tapping IT value of 1.5 in-lbs was selected. Next, 15 test specimens (n=30) were measured with digital calipers, probed, tapped, and instrumented using a paired comparison between the two threshold tapping IT values (Group 1: 1.5 in-lbs; Group 2: 2.5 in-lbs), randomly assigned to the left or right pedicle on each specimen. Each pedicle was incrementally tapped to increasing size (3.75, 4.00, 4.50, and 5.50 mm) until the threshold value was reached based on the assigned group. Pedicle screw size was determined by adding 1 mm to the tap size that crossed the threshold torque value. Torque measurements were recorded with each revolution during tap and pedicle screw insertion. Each specimen was then individually potted and pedicle screws pulled out "in-line" with the screw axis at a rate of 0.25 mm/sec. Peak pullout strength (POS) was measured in Newtons (N). The peak tapping IT was significantly increased (50%) in Group 2 (3.23 ± 0.65 in-lbs) compared with Group 1 (2.15 ± 0.56 in-lbs) (p=.0005). The peak screw IT was also significantly increased (19%) in Group 2 (8.99 ± 2.27 in-lbs) compared with Group 1 (7.52 ± 2.96 in-lbs) (p=.02). The pedicle screw pullout strength was also significantly increased (23%) in Group 2 (877.9 ± 235.2 N) compared with Group 1 (712.3 ± 223.1 N) (p=.017). The mean pedicle screw diameter was significantly increased in Group 2 (5.70 ± 1.05 mm) compared with Group 1 (5.00 ± 0.80 mm) (p=.0002). There was also an increased rate of optimal pedicle screw size selection in Group 2 with 9 of 15 (60%) pedicle screws compared with Group 1 with 4 of 15 (26.7%) pedicle screws within 1 mm of the measured pedicle width. There was a moderate correlation for tapping IT with both screw IT (r=0.54; p=.002) and pedicle screw POS (r=0.55; p=.002). Our findings suggest that tapping IT directly correlates with pedicle screw IT, pedicle screw pullout strength, and optimal pedicle screw size. Therefore, tapping IT may be used during thoracic pedicle screw instrumentation as an adjunct to preoperative imaging and clinical experience to maximize fixation strength and optimize pedicle "fit and fill" with the largest screw possible. However, further prospective, in vivo studies are necessary to evaluate the intraoperative use of tapping IT to predict screw loosening/complications. Published by Elsevier Inc.
Yusof, Mohammad Imran; Hassan, Eskandar; Rahmat, Nasazli; Yunus, Rohaizan
2009-04-01
Pedicle involvement in spinal tuberculosis (TB), the prevertebral abscess formation, severity of vertebral body, and disc collapse were evaluated from magnetic resonance imaging (MRI) of the patients. To study the pedicle involvement in spine TB in relation to the degree of vertebral body and disc collapse, prevertebral abscess collection, and degree of kyphosis; and to correlate the occurrence of pedicle involvement and the degree of spinal deformity. There are a few reports describing the posterior element involvement in spinal TB. Typically, the infection resides in the anterior part of the vertebral body endplates and rarely involved the pedicles. There were 31 patients, who had been diagnosed and treated for spinal TB from 2003 to 2007 at our center. Critical evaluation of each patient's MRI was carried out for the pedicle involvement, prevertebral abscess formation, severity of vertebral body, and disc collapse. Spinal TB mostly involved the thoracic level (48.4%). Pedicle involvement was noted in 64.5% of patients, and the highest involvement was at thoracic level. The mean vertebral body, disc collapse, prevertebral abscess, and kyphosis were more severe in pedicle involved group. The posterior spinal element, specifically the pedicle is not uncommonly involved in spinal TB. Pedicle involvement is part of the disease process and usually associated with relatively severe vertebral body and disc destruction, wide prevertebral abscess, and severe kyphosis. Pedicle involvement can be detected early from MRI and need to be documented as it may influence the treatment strategy.
Rajasekaran, S; Bhushan, Manindra; Aiyer, Siddharth; Kanna, Rishi; Shetty, Ajoy Prasad
2018-01-09
To develop a classification based on the technical complexity encountered during pedicle screw insertion and to evaluate the performance of AIRO ® CT navigation system based on this classification, in the clinical scenario of complex spinal deformity. 31 complex spinal deformity correction surgeries were prospectively analyzed for performance of AIRO ® mobile CT-based navigation system. Pedicles were classified according to complexity of insertion into five types. Analysis was performed to estimate the accuracy of screw placement and time for screw insertion. Breach greater than 2 mm was considered for analysis. 452 pedicle screws were inserted (T1-T6: 116; T7-T12: 171; L1-S1: 165). The average Cobb angle was 68.3° (range 60°-104°). We had 242 grade 2 pedicles, 133 grade 3, and 77 grade 4, and 44 pedicles were unfit for pedicle screw insertion. We noted 27 pedicle screw breach (medial: 10; lateral: 16; anterior: 1). Among lateral breach (n = 16), ten screws were planned for in-out-in pedicle screw insertion. Among lateral breach (n = 16), ten screws were planned for in-out-in pedicle screw insertion. Average screw insertion time was 1.76 ± 0.89 min. After accounting for planned breach, the effective breach rate was 3.8% resulting in 96.2% accuracy for pedicle screw placement. This classification helps compare the accuracy of screw insertion in range of conditions by considering the complexity of screw insertion. Considering the clinical scenario of complex pedicle anatomy in spinal deformity AIRO ® navigation showed an excellent accuracy rate of 96.2%.
Makino, Takahiro; Kaito, Takashi; Fujiwara, Hiroyasu; Yonenobu, Kazuo
2012-08-01
The measurement of transverse pedicle width is still recommended for selecting a screw diameter despite being weakly correlated with the minimum pedicle diameter, except in the upper lumbar spine. The purpose of this study was to reveal the difference between the minimum pedicle diameter and conventional transverse or sagittal pedicle width in degenerative lumbar spines. A total of 50 patients with degenerative lumbar disorders without spondylolysis or lumbar scoliosis of >10° who preoperatively underwent helical CT scans were included. The DICOM data of the scans were reconstructed by imaging software, and the transverse pedicle width (TPW), sagittal pedicle width (SPW), minimum pedicle diameter (MPD), and the cephalocaudal inclination of the pedicles were measured. The mean TPW/SPW/MPD values were 5.46/11.89/5.09 mm at L1, 5.76/10.44/5.39 mm at L2, 7.25/10.23/6.52 mm at L3, 9.01/9.36/6.83 mm at L4, and 12.86/8.95/7.36 mm at L5. There were significant differences between the TPW and MPD at L3, L4, and L5 (p < 0.01) and between the SPW and MPD at all levels (p < 0.01). The MPD was significantly smaller than the TPW and SPW at L3, L4, and L5. The actual measurements of the TPW were not appropriate for use as a direct index for the optimal pedicle screw diameter at these levels. Surgeons should be careful in determining pedicle screw diameter based on plain CT scans especially in the lower lumbar spine.
Congenital Partial Absence of Trapezius with Variant Pattern of Rectus Sheath.
Tigga, Sarika Rachel; Goswami, Preeti; Khanna, Jugesh
2016-04-01
Musculocutaneous pedicled/free flaps are an essential prerequisite for reconstructive surgery. Amongst the trunk muscles commonly harvested for flaps, the trapezius and rectus abdominis provide satisfactory coverage for cranial and trunk defects. unilateral/bilateral or partial congenital absence of trapezius muscle is well documented and may result in muscular imbalances compromising posture and limb movements. During routine cadaveric dissection, we encountered a case of bilateral partial absence of occipital part of the trapezius muscle. Concurrently, the ventral abdominal musculature displayed the aponeurosis of transversus abdominis muscle solely forming the posterior wall of the rectus sheath. These conjointly occurring anomalies advocate a compensatory strengthening of the anterior wall of rectus sheath in response to the congenital absence of occipital part of the trapezius, probably to counteract the postural instability. The present study focuses on recognition of compensatory mechanisms resulting from congenital variations as identification of such processes may prevent chronic debilitating conditions.
Zhang, Ying; Xie, Jingming; Wang, Yingsong; Bi, Ni; Zhao, Zhi; Li, Tao
2014-08-13
Posterior vertebral column resection (PVCR) is an effective alternative for treating rigid and severe spinal deformities. Accurate placement of pedicle screws, especially apically, is crucial. As morphologic evaluations of thoracic pedicles have not provided objective criteria, we propose a thoracic pedicle classification for treating rigid and severe spinal deformities. A consecutive series of 56 patients with severe and rigid spinal deformities who underwent PVCR at a single institution were reviewed retrospectively. Altogether, 1098 screws were inserted into thoracic pedicles at T2-T12. Based on the inner cortical width of the thoracic pedicles, the patients were divided into four groups: group 1 (0-1.0 mm), group 2 (1.1-2.0 mm), group 3 (2.1-3.0 mm), group 4 (≥3.1 mm). The proportion of screws accurately inserted in thoracic pedicles for each group was calculated. Statistical analysis was also performed regarding types of thoracic pedicles classified by Lenke et al. (SPINE 35:1836-1842, 2010) using a morphological method. There were statistically significant differences in the rates of screws inserted in thoracic pedicles between the groups (P < 0.008) except groups 3 and 4 (P > 0.008), which were then combined. The accuracies for the three new groups were 35.05%, 65.34%, and 88.32%, respectively, with statistically significant differences between the groups (P < 0.017). Rates of screws inserted in thoracic pedicles classified by Lenke et al. (SPINE 35:1836-1842, 2010) were 82.31%, 83.40%, 80.00%, and 30.28% for types A, B, C, and D, respectively. There was no statistically significant difference (P > 0.008) between these types except between type D and the other three types (P < 0.008). The inner cortical width of thoracic pedicles is the sole factor crucial for accurate placement of thoracic pedicle screws. We propose a computed tomography-based classification of the pedicle's inner cortical width: type I thoracic pedicle: absent channel, inner cortical width of 0-1 mm; type II: presence of a channel of which type IIa has an inner cortical width of 1.1-2.0 mm and type IIb a width of ≥2.1 mm. The proposed classification can help surgeons predict whether screws can be inserted into the thoracic pedicle, thus guiding instrumentation when PVCR is performed.
Youssef, J A; McKinley, T O; Yerby, S A; McLain, R F
1999-06-01
A bending analysis of pedicle screws inserted into vertebral body analogues. Intravertebral and intrapedicular pedicle screw bending moments were studied as a function of sagittal insertion angle. To determine how the pedicle screw bending moment is affected by changes in the insertion angle. There is a significant incidence of failure when pedicle screws are used to instrument unstable spinal segments. Extrinsic factors that affect screw bending failure have been poorly characterized. Previous work has demonstrated that intrapedicular pedicle screw bending moments are significantly affected by the sagittal location and depth of pedicle screw placement. Pedicle screw transducers were inserted in analogue vertebrae at one of three orientations: 7 degrees cephalad (toward the superior endplate), 7 degrees caudal (toward the inferior endplate), or parallel to the superior endplate (control). An axial load was applied to the superior endplate of the vertebra, and screw bending moments were recorded directly from the transducers. Screws angled 7 degrees cephalad developed significantly greater mean intrapedicular bending moments compared with screws inserted caudal or control screws. There was no significant difference in bending moments realized within the vertebral body for the three screw positions. Angulating pedicle screws toward the superior endplate increased bending moments within the pedicle. If attention to optimal screw insertion technique can reduce bending moments and potential for screw failure without increasing morbidity, surgical risk, or operative time, then proper insertion technique takes on new importance.
Biomechanical Analysis of an Expandable Lumbar Interbody Spacer.
Soriano-Baron, Hector; Newcomb, Anna G U S; Malhotra, Devika; Palma, Atilio E; Martinez-Del-Campo, Eduardo; Crawford, Neil R; Theodore, Nicholas; Kelly, Brian P; Kaibara, Taro
2018-06-01
Recently developed expandable interbody spacers are widely accepted in spinal surgery; however, the resulting biomechanical effects of their use have not yet been fully studied. We analyzed the biomechanical effects of an expandable polyetheretherketone interbody spacer inserted through a bilateral posterior approach with and without different modalities of posterior augmentation. Biomechanical nondestructive flexibility testing was performed in 7 human cadaveric lumbar (L2-L5) specimens followed by axial compressive loading. Each specimen was tested under 6 conditions: 1) intact, 2) bilateral L3-L4 cortical screw/rod (CSR) alone, 3) WaveD alone, 4) WaveD + CSR, 5) WaveD + bilateral L3-L4 pedicle screw/rod (PSR), and 6) WaveD + CSR/PSR, where CSR/PSR was a hybrid construct comprising bilateral cortical-level L3 and pedicle-level L4 screws interconnected by rods. The range of motion (ROM) with the interbody spacer alone decreased significantly compared with the intact condition during flexion-extension (P = 0.02) but not during lateral bending or axial rotation (P ≥ 0.19). The addition of CSR or PSR to the interbody spacer alone condition significantly decreased the ROM compared with the interbody spacer alone (P ≤ 0.002); and WaveD + CSR, WaveD + PSR, and WaveD + CSR/PSR (hybrid) (P ≥ 0.29) did not differ. The axial compressive stiffness (resistance to change in foraminal height during compressive loading) with the interbody spacer alone did not differ from the intact condition (P = 0.96), whereas WaveD + posterior instrumentation significantly increased compressive stiffness compared with the intact condition and the interbody spacer alone (P ≤ 0.001). The WaveD alone significantly reduced ROM during flexion-extension while maintaining the axial compressive stiffness. CSR, PSR, and CSR/PSR hybrid constructs were all effective in augmenting the expandable interbody spacer system and improving its stability. Copyright © 2018 Elsevier Inc. All rights reserved.
Meldrum, Dara; Herdman, Susan; Moloney, Roisin; Murray, Deirdre; Duffy, Douglas; Malone, Kareena; French, Helen; Hone, Stephen; Conroy, Ronan; McConn-Walsh, Rory
2012-03-26
Unilateral peripheral vestibular loss results in gait and balance impairment, dizziness and oscillopsia. Vestibular rehabilitation benefits patients but optimal treatment remains unknown. Virtual reality is an emerging tool in rehabilitation and provides opportunities to improve both outcomes and patient satisfaction with treatment. The Nintendo Wii Fit Plus® (NWFP) is a low cost virtual reality system that challenges balance and provides visual and auditory feedback. It may augment the motor learning that is required to improve balance and gait, but no trials to date have investigated efficacy. In a single (assessor) blind, two centre randomised controlled superiority trial, 80 patients with unilateral peripheral vestibular loss will be randomised to either conventional or virtual reality based (NWFP) vestibular rehabilitation for 6 weeks. The primary outcome measure is gait speed (measured with three dimensional gait analysis). Secondary outcomes include computerised posturography, dynamic visual acuity, and validated questionnaires on dizziness, confidence and anxiety/depression. Outcome will be assessed post treatment (8 weeks) and at 6 months. Advances in the gaming industry have allowed mass production of highly sophisticated low cost virtual reality systems that incorporate technology previously not accessible to most therapists and patients. Importantly, they are not confined to rehabilitation departments, can be used at home and provide an accurate record of adherence to exercise. The benefits of providing augmented feedback, increasing intensity of exercise and accurately measuring adherence may improve conventional vestibular rehabilitation but efficacy must first be demonstrated. Clinical trials.gov identifier: NCT01442623.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rees, Thomas D.
1961-01-01
Successful repair by plastic surgery of nonhealing ulceration of the chest wall, induced by radiotherapy for breast cancer, is described. Reconstruction of the chest wali defect by pedicle flap coverage was carried out. Radiation injury extended through the entire thickness of the chest wall and osteoradionecrosis of the ribs was present. Reconstruction with thoracoabdominal tube was considered to be the best technique, so a 4- by 9-in. tube pedicle was constructed. The underlying donor wound of the pedicle was covered with a split- thickness skin graft. Healing was without incident, and approximates 3 weeks after formation, the inferior end ofmore » this tube pedicle was migrated to the left epigastrium as an intermediate step. Healing was uncomplicated, and the lateral attachment of the pedicle was partially severed. Three weeks later, resection of all avascular tissue along with portions of the fourth and fifth ribs was carried out. This created a full-thickness chest wall defect measuring 4 by 8 in., with the anterior surface of the pericardial sac exposed in the wound. The end of the abdominal tube pedicle was elevated from its bed, rotated into position, and sutured to the healthy margins of the chest wall defect. The exposed subcutaneous fat of the undersurface of the pedicle was placed in juxtaposition to the pericardium. A split-thickness skin graft was cut from the skin of the left thigh and draped over the pedicle flap donor wound. All sutured wounds healed per primum and the entire skin graft survived. The inferior inset of the tube pedicle was cut free and the pedicle flap was tailored into position 6 weeks later. The patient was discharged from the hospital in good condition and engaged in normal activities. An attempt was made to provide protection for the heart beneath the pedicle inset by introduction of diced homologous cartilage grafts, just beneath the skin of the pedicle flap. This healed with the formation of a thick fibrocartilaginous structure providing some protection for the pericardial contents beneath.« less
Chen, Jianchong; Wu, Zuhuang; Zhu, Jianxian; Huang, Yongxin; Xie, Baogen
2011-10-01
To summarize the therapeutic effectiveness of incorporating pedicled retrograde flap of forearm transplantation for reconstructing severe contracture of the first web space and wrist. Between November 2005 and February 2010, 26 patients with severe contracture of the first web and wrist were treated. There were 18 males and 8 females with an average age of 27 years (range, 12-45 years). The locations were the right sides in 15 cases and the left sides in 11 cases. The injury reason included hot water scald in 7 cases, explosion hurt in 5 cases, traffic accident in 3 cases, hot pressing in 5 cases, and flame burns in 6 cases. The duration of scar contracture ranged from 6 to 26 months with an average of 11 months. According to the evaluation standard by GU Yudong et al., all had severe contracture of the first web space, and concomitant injuries included adduction deformity thumb, limitation of the thumb extension and opposition function, and carpometacarpal flexion joint deformity. After scar contracture was released, the defect size ranged from 5.8 cm x 4.5 cm to 11.3 cm x 7.2 cm, which were repaired by the incorporating pedicled retrograde flap of forearm of 6.5 cm x 5.0 cm to 12.5 cm x 8.0 cm at size. The donor sites were directly sutured or repaired with skin graft. Blister and partial necrosis occurred at the distal end of the flaps in 2 cases, which were cured after dressing change. The other flaps survived and wounds healed by first intention. Incisions at donor sites healed by first intention. Twenty-six patients were followed up 6 to 24 months (mean, 15 months). The patients had functional recovery in thumb adduction and opposition at different degrees. At 6 months after operation, according to the Swanson et al. AMA system for total thumb activity, the total thumb function was improved significantly, and according to Jensen et al. measurement, the width and angle of the first web space were significantly increased, all showing significant differences (P < 0.05). Incorporating pedicled retrograde flap of forearm transplantation for repairing severe contracture of the first web space and wrist could augment the first web space and improve the wrist flexible function.
Okuyama, Koichiro; Kido, Tadato; Unoki, Eiki; Chiba, Mitsuho
2007-02-01
To determine the validity of posterior lumbar interbody fusion (PLIF) using a titanium cage filled with excised facet joint bone and a pedicle screw for degenerative spondylolisthesis. PLIF using a titanium cage filled with excised facet joint bone and a pedicle screw was performed in 28 consecutive patients (men 10, women 18). The mean age of the patients was 60 years (range, 52 to 75 y) at the time of surgery. The mean follow-up period was 2.3 years (range, 2.0 to 4.5 y). The operation was done at L3/4 in 5, L4/5 in 20, and L3/4/5 in 3 patients. The mean operative bleeding was 318+/-151 g (mean+/-standard deviation), and the mean operative time was 3.34+/-0.57 hours per fixed segment. Clinical outcome was assessed by Denis' Pain and Work scale. Radiologic assessment was done using Boxell's method. Fusion outcome was assessed using an established criteria. On Pain scale, 20 and 8 patients were rated P4 and P5 before surgery, and 11, 12, 2, 2, and 1 patients were rated P1, P2, P3, P4, and P5 at final follow-up, respectively. On Work scale (for only physical labors), 12 and 9 patients were rated W4 and W5, before surgery, and 12, 5, 1, and 3 patients were rated W1, W2, W3 and W5 at final follow-up, respectively. There was significant difference in clinical outcome (P<0.01, Wilcoxon singled-rank test) The mean %Slip and Slip Angle was 17.9+/-8.1% and 3.9+/-5.8 degrees before surgery. The mean % Slip and Slip Angle was 5.4+/-4.4% and -2.0+/-4.8 degrees at final follow-up. There was a significant difference between the values (P<0.01, paired t test). "Union" and "probable union" was determined in 29 (93.5%) and 2 (6.5%) of 31 operated segments at 2.3 years (range, 2.0 to 4.5 y), postoperatively. PLIF using a titanium cage filled with excised facet joint bone and a pedicle screw provided a satisfactory clinical outcome and an excellent union rate without harvesting and grafting the autologous iliac bone.
Wang, Jeremy C; Spenciner, David; Robinson, James C
2006-02-01
The authors studied the biomechanical properties of a novel spinous process stabilization plate (CD HORIZON SPIRE Spinal System) and present the results in comparison with those of other posterior fixation methods. Ten functional cadaveric lumbar segments were subjected to nondestructive quasistatic loading forces in 10 different conditions: intact, destabilized (discectomy), fitted with spinous process plate (SPP) alone, with anterior-column support (ACS) alone, ACS with SPP, ACS with posterior translaminar facet screw (PTFS) fixation, ACS with unilateral pedicle screw and rod (UPSR) fixation, ACS with bilateral pedicle screw and rod (BPSR) fixation, UPSR alone, or BPSR alone. Stiffness and range of motion (ROM) data were compared using a repeated-measures, one-way analysis of variance. The construct with greatest mean limitation of flexion-extension ROM was ACS/SPP at 4.14 degrees whereas it was 5.75 degrees for ACS/UPSR fixation, 5.03 degrees for ACS/BPSR fixation, and 10.13 degrees for the intact spine. The SPIRE plate alone also provided greater flexion and extension stiffness, with less ROM than other posterior stabilization options. Fixation with BPSR with or without ACS resulted in the stiffest construct in lateral bending and axial rotation. The SPP and UPSR fixation groups were equivalent in resisting lateral bending and axial rotation forces with or without ACS. The SPIRE plate effectively stabilized the spine, and the test results compare favorably with other fixation techniques that are more time consuming to perform and have greater inherent risks.
Sanuki, Tetsuji; Yumoto, Eiji; Nishimoto, Kohei; Kodama, Narihiro; Kodama, Haruka; Minoda, Ryosei
2015-04-01
To evaluate the long-term efficacy of laryngeal reinnervation via refined nerve-muscle pedicle (NMP) flap implantation combined with arytenoid adduction to treat unilateral vocal fold paralysis (UVFP), employing laryngeal electromyography (LEMG), coronal imaging, and phonatory function assessment. Case series with chart review. University hospital. We retrospectively reviewed 12 UVFP patients who underwent refined NMP implantation with arytenoid adduction. Videostroboscopy, phonatory functional analysis, LEMG, and coronal imaging were performed before and 2 years after surgery. In LEMG analysis, a 4-point scale was employed to grade motor unit (MU) recruitment: 4+ reflected no recruitment, 3+ greatly decreased recruitment, 2+ moderately decreased recruitment, and 1+ mildly decreased activity, associated with less than the full interference pattern. Coronal images were assessed in terms of differences in thickness and the vertical positions of the vocal folds. Phonatory function improved significantly after operation in all patients. In terms of LEMG findings, the preoperative MU recruitment scores were 1+ in no patients, 2+ in 4 patients, 3+ in 1 patient, and 4+ in 7 patients. Postoperative MU recruitment results were 1+ in 6 patients, 2+ in 5 patients, 3+ in 1 patient, and 4+ in no patients. Thinning of the affected fold during phonation was evident preoperatively in 9 of 10 patients. The affected and healthy folds were equal in volume in 4 of 9 patients postoperatively. The LEMG findings and coronal imaging suggest that NMP implantation may have enabled successful reinnervation of the laryngeal muscles of UVFP patients. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.
2012-01-01
Background A cursory review of the current socket preservation literatures well depicts the necessity of further esthetic considerations through the corrective procedures of the alveolar ridge upon and post extraction. A new technique has been described here is a rotational pedicle combined epithelialized and connective tissue graft (RPC graft) adjunct with immediate guided tissue regeneration (GBR) procedure. Results We reviewed this technique through a case report and discuss it’s benefit in compare to other socket preservation procedures. Conclusion The main advantages of RPC graft would be summarized as follows: stable primary closure during bone remodeling, saving or crating sufficient vestibular depth, making adequate keratinized gingiva on the buccal surface, and being esthetically pleasant. PMID:22540920
Expeditionary Theater Opening Strategy
2013-03-01
TSC and ESC requires augmentation from other U.S. Army elements in order to provide that capability.44 The U.S. competitive advantage over all other...the increased competition to access the global lines of communications, the U.S. may no longer enjoy the freedom to unilaterally deploy forces... Logistics , 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT UU 18. NUMBER OF PAGES 34 19a. NAME OF
Sugioka, Atsushi; Kato, Yutaro; Tanahashi, Yoshinao
2017-01-01
Abstract Anatomical liver resection with the Glissonean pedicle isolation is widely approved as an essential procedure for safety and curability. Especially, the extrahepatic Glissonean pedicle isolation without parenchymal destruction should be an ideal procedure. However, the surgical technique has not been standardized due to a lack of anatomical understanding. Herein, we proposed a novel comprehensive surgical anatomy of the liver based on Laennec's capsule that would give a theoretical background to the extrahepatic Glissonean pedicle isolation. Laennec's capsule is the proper membrane that covers not only the entire surface of the liver including the bare area but also the intrahepatic parenchyma surrounding the Glissonean pedicles. Consequently, there exists a gap between the Glissonean pedicle and Laennec's capsule that could be reached extrahepatically and allows us to isolate the extrahepatic Glissonean pedicle without parenchymal destruction systematically. For standardization, it is essential to approach the “six gates” indicated by the “four anatomical landmarks”: the Arantius plate, the umbilical plate, the cystic plate and the Glissonean pedicle of the caudate process (G1c). This novel anatomy would contribute to standardize the surgical techniques of the systematic extrahepatic Glissonean pedicle isolation for anatomical liver resection including laparoscopic or robotic liver resection and to bring innovative changes in hepatobiliary surgery for spreading safe and curable liver resection. PMID:28156078
Hartmann, C E A; Branford, O A; Malhotra, A; Chana, J S
2013-07-01
The latissimus dorsi flap, first performed by Tansini in 1892, was popularised for use by Olivari in 1976. The successful transfer of a latissimus dorsi flap during breast reconstruction has previously been thought to be dependent on having an intact thoracodorsal pedicle to ensure flap survival. It is well documented that the flap may also survive on the serratus branch in thoracodorsal pedicle division. We report a case of a 52-year-old female patient who underwent successful delayed breast reconstruction with a latissimus dorsi flap following previous mastectomy and axillary node clearance. Intraoperatively, the thoracodorsal pedicle and serratus branch were found to have been previously divided. On postoperative computer tomographic angiography the thoracodorsal pedicle was shown to be divided together with the serratus branch. The flap was seen to be supplied by the lateral thoracic artery. To our knowledge survival of a pedicled latissimus dorsi flap in breast reconstruction with a vascular supply from this vessel following thoracodorsal pedicle division has not previously been described. Previous thoracodorsal pedicle and serratus branch division may not be an absolute contraindication for the use of the latissimus dorsi flap in breast reconstruction, depending on the results of preoperative Doppler or computer tomographic angiography studies. Copyright © 2012 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Gao, Bo; Gao, Wenjie; Chen, Chong; Wang, Qinghua; Lin, Shaochun; Xu, Caixia; Huang, Dongsheng; Su, Peiqiang
2017-11-01
Describing the morphologic features of the thoracic pedicle in patients with adolescent idiopathic scoliosis is necessary for placement of pedicle screws. Previous studies showed inadequate reliability owing to small sample size and heterogeneity of the patients surveyed. To use CT scans (1) to describe the morphologic features of 2718 thoracic pedicles from 60 female patients with Lenke Type 1 adolescent idiopathic scoliosis and 60 age-, sex-, and height-matched controls; and (2) to classify the pedicles in three types based on pedicle width and analyze the distribution of each type. A total of 2718 pedicles from 60 female patients with Lenke Type 1 adolescent idiopathic scoliosis and 60 matched female controls were analyzed via CT. All patients surveyed were diagnosed with adolescent idiopathic scoliosis, Lenke Type 1, at the First Affiliated Hospital of Sun Yat-sen University, and all underwent pedicle screw fixation between January 2008 and December 2013 with preoperative radiographs and CT images on file. We routinely obtained CT scans before these procedures; all patients who underwent surgery during that period had CT scans, and all were available for analysis here. Control subjects had CT scans for other clinical indications and had no abnormal findings of the spine. The control subjects were chosen to match patients in terms of age (15 ± 2.6 years versus 15 ± 2.6 years) and sex. Height of the two groups also was matched (154 ± 9 cm versus 155 ± 10 cm; mean difference, -1.06 cm; 95% CI, -1.24 to -0.81 cm; p < 0.001). Pedicle width and length were measured from T1 to T12. The thoracic spine was classified in four regions: apical vertebra in the structural curve (AV-SC), nonapical vertebra in the structural curve (NAV-SC), apical vertebra in the nonstructural curve (AV-NSC), and nonapical vertebra in the nonstructural curve (NAV-NSC). Pedicles were classified in three types: pedicle width less than 2 mm as Type I, 2 mm to 4 mm as Type II, and greater than 4 mm as Type III. Types I and II were defined as dysplastic pedicles. Paired t test, independent samples t test, one-way ANOVA, followed by Bonferroni's post hoc test and chi-square or Fisher's exact tests were used for statistical comparisons between patients and controls, as appropriate. No difference was found between pedicle width on the convex side (PWv) and in controls (PWn), but pedicle width on the concave side (PWc) (4.99 ± 1.87 mm) was found to be narrower than PWv (6 ± 1.66 mm) and PWn (6 ± 1.45 mm). The variation degree of pedicle width (VDPW) was greatest in the AV-SC region (34% ± 37%), in comparison to AV-NSC (20% ± 25%) (mean difference, 14%; 95% CI, 1.15%-27%; p = 0.025), NAV-SC (17% ± 30%) (mean difference, 17%; 95% CI, 7%-27%; p < 0.001), and NAV-NSC (11% ± 24%) (mean difference, 24%; 95% CI, 13%-34%; p < 0.001). Dysplastic pedicles appeared more in patients with adolescent idiopathic scoliosis (22%; 293 of 1322) compared with controls (13%; 178 of 1396) (odds ratio [OR] = 0.51; 95% CI, 0.42-0.63; p < 0.001). In patients with adolescent idiopathic scoliosis, they commonly occurred on the concave side 34% (228 of 661) and on the AV-SC region (32%; 43 of 136). Pedicle width on the concave side was narrower than pedicle width on the convex side and pedicle width in healthy control subjects. The apical vertebra in the structural curve was the most variegated region of the curve with the highest prevalence of dysplastic pedicles. Our study can help surgeons perform preoperative assessments in females with adolescent idiopathic scoliosis, and with preoperative and intraoperative management for difficult pedicle screw placement. In particular, our results suggest that surgeons should exercise increased vigilance when selecting pedicle screw dimensions, especially in the concave aspect of the mid-thoracic curve, to avoid cortical breeches. Future studies should evaluate other Lenke types of adolescent idiopathic scoliosis, and males with adolescent idiopathic scoliosis.
Wang, Juan; Zhou, Yicheng; Hu, Ning; Wang, Renfa
2006-01-01
To investigate the value of the guidance of three dimensional (3-D) reconstruction of multi-slice spiral CT (MSCT) for the placement of pedicle screws, the 3-D anatomical data of the thoracic pedicles were measured by MSCT in two embalmed human cadaveric thoracic pedicles spines (T1-T10) to guide the insertion of pedicle screws. After pulling the screws out, the pathways were filled with contrast media. The PW, PH, TSA and SSA of developed pathways were measured on the CT images and they were also measured on the real objects by caliper and goniometer. Analysis of variance demonstrated that the difference between the CT scans and real objects had no statistical significance (P > 0.05). Moreover, the difference between pedicle axis and developed pathway also had no statistical significance (P > 0.05). The data obtained from 3-D reconstruction of MSCT demonstrated that individualized standards, are not only accurate but also helpful for the successful placement of pedicle screws.
Yu, Bin-Sheng; Yang, Zhan-Kun; Li, Ze-Min; Zeng, Li-Wen; Wang, Li-Bing; Lu, William Weijia
2011-08-01
An in vitro biomechanical cadaver study. To evaluate the pull-out strength after 5000 cyclic loading among 4 revision techniques for the loosened iliac screw using corticocancellous bone, longer screw, traditional cement augmentation, and boring cement augmentation. Iliac screw loosening is still a clinical problem for lumbo-iliac fusion. Although many revision techniques using corticocancellous bone, larger screw, and polymethylmethacrylate (PMMA) augmentation were applied in repairing pedicle screw loosening, their biomechanical effects on the loosened iliac screw remain undetermined. Eight fresh human cadaver pelvises with the bone mineral density values ranging from 0.83 to 0.97 g/cm were adopted in this study. After testing the primary screw of 7.5 mm diameter and 70 mm length, 4 revision techniques were sequentially established and tested on the same pelvis as follows: corticocancellous bone, longer screw with 100 mm length, traditional PMMA augmentation, and boring PMMA augmentation. The difference of the boring technique from traditional PMMA augmentation is that PMMA was injected into the screw tract through 3 boring holes of outer cortical shell without removing the screw. On an MTS machine, after 5000 cyclic compressive loading of -200∼-500 N to the screw head, axial maximum pull-out strengths of the 5 screws were measured and analyzed. The pull-out strengths of the primary screw and 4 revised screws with corticocancellous bone, longer screw and traditional and boring PMMA augmentation were 1167 N, 361 N, 854 N, 1954 N, and 1820 N, respectively. Although longer screw method obtained significantly higher pull-out strength than corticocancellous bone (P<0.05), the revised screws using these 2 techniques exhibited notably lower pull-out strength than the primary screw and 2 PMMA-augmented screws (P<0.05). Either traditional or boring PMMA screw showed obviously higher pull-out strength than the primary screw (P<0.05); however, no significant difference of pull-out strength was detected between the 2 PMMA screws (P>0.05). Wadding corticocancellous bone and increasing screw length failed to provide sufficient anchoring strength for a loosened iliac screw; however, both traditional and boring PMMA-augmented techniques could effectively increase the fixation strength. On the basis of the viewpoint of minimal invasion, the boring PMMA augmentation may serve as a suitable salvage technique for iliac screw loosening.
Robertson, Peter A; Armstrong, William A; Woods, Daniel L; Rawlinson, Jeremy J
2018-04-24
Controlled cadaveric study of surgical technique in Transforaminal and Posterior Lumbar Interbody Fusion (TLIF & PLIF) OBJECTIVE.: To evaluate the contribution of surgical techniques and cage variables in lordosis re-creation in posterior interbody fusion (TLIF/PLIF). The major contributors to lumbar lordosis are the lordotic lower lumbar discs. The pathologies requiring treatment with segmental fusion are frequently hypolordotic or kyphotic. Current posterior based interbody techniques have a poor track record for recreating lordosis, although re-creation of lordosis with optimum anatomical alignment is associated with better outcomes and reduced adjacent segment change needing revision. It is unclear whether surgical techniques or cage parameters contribute significantly to lordosis re-creation. Eight instrumented cadaveric motion segments were evaluated with pre and post experimental radiological assessment of lordosis. Each motion segment was instrumented with pedicle screw fixation to allow segmental stabilization. The surgical procedures were unilateral TLIF with an 18° lordotic and 27 mm length cage, unilateral TLIF (18°, 27 mm) with bilateral facetectomy, unilateral TLIF (18°, 27 mm) with posterior column osteotomy, PLIF with bilateral cages (18°, 22 mm), and PLIF with bilateral cages (24°, 22 mm). Cage insertion used and 'insert and rotate' technique. Pooled results demonstrated a mean increase in lordosis of 2.2° with each procedural step (Lordosis increase was serially 1.8°, 3.5°, 1.6°, 2.5° & 1.6° through the procedures). TLIF and PLIF with posterior column osteotomy increased lordosis significantly compared with Unilateral TLIF and TLIF with bilateral facetectomy. The major contributors to lordosis re-creation were posterior column osteotomy, and PLIF with paired shorter cages rather than TLIF. This study demonstrates that the surgical approach to posterior interbody surgery influences lordosis gain and posterior column osteotomy optimizes lordosis gain in TLIF. The bilateral cages used in PLIF are shorter and associated with further gain in lordosis. This information has the potential to aid surgical planning when attempting to recreate lordosis to optimize outcomes. N/A.
Elgafy, Hossein; Miller, Jacob D; Benedict, Gregory M; Seal, Ryan J; Liu, Jiayong
2013-07-01
There have been many reports outlining differing methods for managing a broken S1 screw. To the authors' best knowledge, the technique used in the present study has not been described previously. It involves insertion of a second pedicle screw without removing the broken screw shaft. Radiological study, literature review, and two case reports of the surgical technique. To report a proposed new surgical technique for management of broken S1 pedicle screws. Computed tomography (CT) scans of 50 patients with a total of 100 S1 pedicles were analyzed. There were 25 male and 25 female patients with an average age of 51 years ranging from 36 to 68 years. The cephalad-caudal length, medial-lateral width, and cross-sectional area of the S1 pedicle were measured and compared with the diameter of a pedicle screw to illustrate the possibility of inserting a second screw in S1 pedicle without removal of the broken screw shaft. Two case reports of the proposed technique are presented. The left and right S1 pedicle cross-sectional area in female measured 456.00 ± 4.00 and 457.00 ± 3.00 mm(2), respectively. The left and right S1 pedicle cross-section area in male measured 638.00 ± 2.00 and 639.00 ± 1.00 mm(2), respectively. There were statistically significant differences when comparing male and female S1 pedicle length, width, and cross-sectional area (p<.05). At 2-year follow-up, the two case reports of the proposed technique showed resolution of low back pain and radicular pain. Plain radiograph and CT scan showed posterolateral fusion mass and hardware in good position with no evidence of screw loosening. The S1 pedicle dimensions measured on CT scan reviewed in the present study showed that it may be anatomically feasible to place a second screw through the S1 pedicle without the removal of the broken screw shaft. This treatment method will reduce the complications associated with other described revision strategies for broken S1 screws. Published by Elsevier Inc.
Conjunctival dysfunction and mitomycin C-induced hypotony.
Sihota, R; Dada, T; Gupta, S D; Sharma, S; Arora, R; Agarwal, H C
2000-10-01
To determine the role of a physically intact conjunctiva in the development of chronic hypotony after mitomycin C-enhanced trabeculectomy. Three patients with mitomycin C-related hypotonic maculopathy, but without a leak on Siedel test, had a thorough evaluation of the bleb area and an anterior segment fluorescein angiography. The bleb was excised and a pedicle flap, rotated from the temporal conjunctiva, was sutured to cover the defect superiorly. The scleral flap and its sutures were not disturbed. The excised bleb was subjected to light and electron microscopy. The Seidel test result was negative in all patients, but late phases of the anterior segment angiography showed a generalized seepage of aqueous from the bleb. After revision of the bleb, there was a gradual increase in the intraocular pressure, a reversal of the hypotonic maculopathy, and consequent improvement in visual acuity in all three patients, stable up to a minimum follow-up of 18 months. On histopathologic examination, the basement membrane was thickest under thin areas of the epithelium and thinnest below thicker epithelial layers. A dysfunctional conjunctival barrier, as evidenced by the "sweating" of the bleb and histopathologic alterations in the epithelial barrier, could be responsible for the hypotonic maculopathy in these patients. Excision of the conjunctiva alone and replacement by a pedicle conjunctival graft offers a safe and effective method of treating chronic hypotony after mitomycin C-augmented trabeculectomy in such patients.
Supraclavicular Artery Flap for Head and Neck Oncologic Reconstruction: An Emerging Alternative
Shenoy, Ashok; Patil, Vijayraj S.; Prithvi, B. S.; Chavan, P.; Halkud, Rajshekar
2013-01-01
Aim. Head and Neck oncologic resections often leave complex defects which are challenging to reconstruct. The need of the hour is a versatile flap which has the advantages of both a regional flap (viz. reliable and easy to harvest) and a free flap (thin, pliable with good colour match). In this a study we assessed the usefulness of the supraclavicular artery flap in head and neck oncologic defects. Materials and Method. The flap was used as a pedicled fasciocutanous and was based on the transverse supraclavicular artery. We assessed this reconstructive option for complications as well as its and functional out comes. Results. Eleven cases underwent supraclavicular artery flap between 20011-2012 of which 5 were males and 6 females. Mean defect size was 5 cm × 6 cm. Nine donor sites were closed primarily and 1 required split skin grafting. We encountered one complete flap loss which was attributed to a band of constricting skin bridge over the vascular pedicle in a defect involving lateral third of midface. Two patient developed pharyngeocutaneous fistula (without flap loss) out of 3 patients who underwent augmentation pharyngoplasty post Near total laryngectomy. Conclusion. Supra clavicular artery flap is a thin versatile, reliable, easy to harvest, with good cosmetic and functional outcome at both ends (recipient and donor) for reconstructing head and neck oncologic defects. PMID:24490064
Jost, Gregory F; Walti, Jonas; Mariani, Luigi; Schaeren, Stefan; Cattin, Philippe
2018-05-30
Inertial measurement units (IMUs) are microelectromechanical systems used to track orientation and motion. To use instruments mounted with IMUs in combination with a 3- and 2-dimensional (3D/2D) rendering of the computed-tomography scan (CT) to guide implantation of pedicle screws. Pedicle screws were implanted from T1 to S1 in 2 human cadavers. A software application enabled the surgeon to select the starting points and trajectories on a 3D/2D image of the spine, then locate these starting points on the exposed spine and apply the IMU-mounted instruments to reproduce the trajectories. The position of the screws was evaluated on the postoperative CT scan. A total of 72 pedicle screws were implanted. Thirty-seven (77%) of the thoracic screws were within the pedicle (Heary I), 7 (15%) showed a lateral breach of the pedicle, and 4 (8%) violated the anterior or lateral vertebral body (Heary III). In the lumbar spine and S1, 21 screws (88%) were within the pedicle (Gertzbein 0), 2 (8%) screws had a pedicle wall breach < 2 mm (Gertzbein 1), and 1 > 2 to < 4 mm (Gertzbein 2). In the second cadaver, the position was compared to the intraoperatively shown virtual position. The median offset was 3°(mean 3° ± 2°, variance 5, range 0°-9°) in the sagittal plane and 3° (mean 4° ± 3°, variance 9, range 0°-12°) in the axial plane. IMU-assisted implantation of pedicle screws combined with an intraoperative 3D/2D visualization of the spine enabled the surgeon to precisely implant pedicle screws on the exposed spine.
Jin, Mengran; Liu, Zhen; Qiu, Yong; Yan, Huang; Han, Xiao; Zhu, Zezhang
2017-04-01
To assess the accuracy of O-arm-navigation-based pedicle screw placement in scoliosis surgery and identify the potential risk factors for the misplacement of pedicle screws. One hundred forty four scoliosis patients treated with O-arm-navigation-based pedicle screw instrumentation were enrolled, and 1145 pedicle screws implanted in the apical region of the curves were retrospectively reviewed for accuracy according to post-operative CT images. The potential risk factors and independent predictive factor(s) for the misplaced screws were identified statistically. The overall malpositioning rate of pedicle screw was 9.8%; 54.5% of which were misplaced laterally. Univariate and multivariate logistic regression analysis of clinical and surgical treatment variables indicated that patients with congenital scoliosis (CS) [OR: 1.489 (95% CI: 1.002-2.213; P = 0.035)] and neurofibromatosis type I (NF-1) [OR: 1.785 (95% CI: 1267-2.045; P = 0.026)], middle-thoracic spine [OR: 1.661 (95% CI: 1.107-2.481; P = 0.021)], the concave pedicles [OR: 1.527 (95% CI: 1.020-2.285; P = 0.019)], and the segments three levels away from the tracker [OR: 3.522 (95% CI: 2.357-5.263; P = 0.001)] were independently associated with pedicle screw misplacement. O-arm-assisted navigation does improve the accuracy and safety of pedicle screw placement in scoliosis surgery. However, unavoidable screw malpositioning remained, which occurred significantly more often in patients with CS and NF-1, in middle-thoracic spine, in the concave pedicles, and in the segments three levels away from the tracker.
Sugioka, Atsushi; Kato, Yutaro; Tanahashi, Yoshinao
2017-01-01
Anatomical liver resection with the Glissonean pedicle isolation is widely approved as an essential procedure for safety and curability. Especially, the extrahepatic Glissonean pedicle isolation without parenchymal destruction should be an ideal procedure. However, the surgical technique has not been standardized due to a lack of anatomical understanding. Herein, we proposed a novel comprehensive surgical anatomy of the liver based on Laennec's capsule that would give a theoretical background to the extrahepatic Glissonean pedicle isolation. Laennec's capsule is the proper membrane that covers not only the entire surface of the liver including the bare area but also the intrahepatic parenchyma surrounding the Glissonean pedicles. Consequently, there exists a gap between the Glissonean pedicle and Laennec's capsule that could be reached extrahepatically and allows us to isolate the extrahepatic Glissonean pedicle without parenchymal destruction systematically. For standardization, it is essential to approach the "six gates" indicated by the "four anatomical landmarks": the Arantius plate, the umbilical plate, the cystic plate and the Glissonean pedicle of the caudate process (G1c). This novel anatomy would contribute to standardize the surgical techniques of the systematic extrahepatic Glissonean pedicle isolation for anatomical liver resection including laparoscopic or robotic liver resection and to bring innovative changes in hepatobiliary surgery for spreading safe and curable liver resection. © 2017 The Authors. Journal of Hepato-Biliary-Pancreatic Sciences published by John Wiley & Sons Australia, Ltd on behalf of Japanese Society of Hepato-Biliary-Pancreatic Surgery.
[Reconstruction of facial soft tissue defects with pedicled expanded flaps].
Yangqun, Li; Yong, Tang; Wen, Chen; Zhe, Yang; Muxin, Zhao; Lisi, Xu; Chunmei, Hu; Yuanyuan, Liu; Ning, Ma; Jun, Feng; Weixin, Wang
2014-09-01
To investigate the application of pedicled expanded flaps for the reconstruction of facial soft tissue defects. The expanded skin flaps, pedicled with orbicularis oculi muscle, submental artery, the branch of facial artery, superficial temporal artery, interior upper arm artery, had similar texture and color as facial soft tissue. The pedicled expanded flaps have repaired the facial soft tissue defects. Between Jan. 2003 to Dec. 2013, 157 cases with facial soft tissue defects were reconstructed by pedicled expanded flaps. Epidermal necrosis happened at the distal end of 8 expanded flaps, pedicled with interior upper arm artery(4 cases), orbicularis oculi muscle(3 cases) and submental artery(1 case), which healed spontaneously after dressing. All the other flaps survived completely with similar color and inconspicuous scar. 112 cases were followed up for 8 months to 8 years. Satisfactory results were achieved in 75 cases. 37 cases with hypertrophic scar at incisions need secondary operation. Island pedicled expanded flap with similar texture and color as facial soft tissue is suitable for facial soft tissue defects. The facial extra-incision and large dog-ear deformity could be avoided.
EFFECT OF PILOT HOLE TAPPING ON PULLOUT STRENGTH AND INSERTION TORQUE OF DUAL CORE PEDICLE SCREWS.
Rosa, Rodrigo César; Silva, Patrícia; Falcai, Maurício José; Shimano, Antônio Carlos; Defino, Helton Luiz Aparecido
2010-01-01
To evaluate the influence of pilot hole tapping on pullout resistance and insertion torque of pedicle screws with a conical core. Mechanical tests using a universal testing machine were performed on pedicle screws with a conical core that were inserted into pedicles in the fifth lumbar vertebra of calves. The insertion torque was measured using a torque meter with a capacity of 10 Nm, which was considered to be the highest torque value. The pilot holes were prepared using a probe of external diameter 3.8 mm and tapping of the same dimensions and thread characteristics as the screw. Decreased insertion torque and pullout resistance were observed in the group with prior tapping of the pilot hole. Pilot hole tapping reduced the insertion torque and pullout resistance of pedicle screws with a conical core that had been inserted into the pedicle of the fifth lumbar vertebra of calves.
NASA Astrophysics Data System (ADS)
Kiriyama, Yoshimori; Yamazaki, Nobutoshi; Nagura, Takeo; Matsumoto, Morio; Chiba, Kazuhiro; Toyama, Yoshiaki
In segmental pedicle screw instrumentation, the relationship between the combinations of pedicle screw placements and the degree of deformity correction was investigated with a three-dimensional rigid body and spring model. The virtual thoracolumbar scoliosis (Cobb’s angle of 47 deg.) was corrected using six different combinations of pedicle-screw placements. As a result, better correction in the axial rotation was obtained with the pedicle screws placed at or close to the apical vertebra than with the screws placed close to the end vertebrae, while the correction in the frontal plane was better with the screws close to the end vertebrae than with those close to the apical vertebra. Additionally, two screws placed in the convex side above and below the apical vertebra provided better correction than two screws placed in the concave side. Effective deformity corrections of scoliosis were obtained with the proper combinations of pedicle screw placements.
Luo, Jiaquan; Wu, Chunyang; Huang, Zhongren; Pan, Zhimin; Li, Zhiyun; Zhong, Junlong; Chen, Yiwei; Han, Zhimin; Cao, Kai
2017-04-01
This is a cadaver specimen study to confirm new pedicle screw (PS) entry point and trajectory for subaxial cervical PS insertion. To assess the accuracy of the lateral vertebral notch-referred PS insertion technique in subaxial cervical spine in cadaver cervical spine. Reported morphometric landmarks used to guide the surgeon in PS insertion show significant variability. In the previous study, we proposed a new technique (as called "notch-referred" technique) primarily based on coronal multiplane reconstruction images (CMRI) and cortical integrity after PS insertion in cadavers. However, the PS position in cadaveric cervical segment was not confirmed radiologically. Therefore, the difference between the pedicle trajectory and the PS trajectory using the notch-referred technique needs to be illuminated. Twelve cadaveric cervical spines were conducted with PS insertion using the lateral vertebral notch-referred technique. The guideline for entry point and trajectory for each vertebra was established based on the morphometric data from our previous study. After 3.5-mm diameter screw insertion, each vertebra was dissected and inspected for pedicle trajectory by CT scan. The pedicle trajectory and PS trajectory were measured and compared in axial plane. The perforation rate was assessed radiologically and was graded from ideal to unacceptable: Grade 0 = screw in pedicle; Grade I = perforation of pedicle wall less than one-fourth of the screw diameter; Grade II = perforation more than one-fourth of the screw diameter but less than one-second; Grade III = perforation more than one-second outside of the screw diameter. In addition, pedicle width between the acceptable and unacceptable screws was compared. A total of 120 pedicle screws were inserted. The perforation rate of pedicle screws was 78.3% in grade 0 (excellent PS position), 10.0% in grade I (good PS position), 8.3% in grade II (fair PS position), and 3.3% in grade III (poor PS position). The overall accepted accuracy of pedicle screws was 96.7% (Grade 0 + Grade I + Grade II), and only 3.3% had critical breach. There was no statistical difference between the pedicle trajectory and PS trajectory (p > 0.05). Compared to the pedicle width (4.4 ± 0.7 mm) in acceptably inserted screw, the unacceptably screw is 3.2 ± 0.3 mm which was statistically different (p < 0.05). The accuracy of the notch-referred PS insertion in cadaveric subaxial cervical spine is satisfactory.
Varghese, Vicky; Krishnan, Venkatesh; Saravana Kumar, Gurunathan
2018-06-01
A biomechanical study. A new biomechanical model of the vertebra has been developed that accounts for the inhomogeneity of bone and the contribution of the pedicle toward the holding strength of a pedicle screw. Pullout strength studies are typically carried out on rigid polyurethane foams that represent the homogeneous vertebral framework of the spine. However, the contribution of the pedicle region, which contributes to the inhomogeneity in this framework, has not been considered in previous investigations. Therefore, we propose a new biomechanical model that can account for the vertebral inhomogeneity, especially the contribution of the pedicles toward the pullout strength of the pedicle screw. A bilayer foam model was developed by joining two foams representing the pedicle and the vertebra. The results of the pullout strength tests performed on the foam models were compared with those from the tests performed on the cadaver lumbar vertebra. Significant differences ( p <0.05) were observed between the pullout strength of the pedicle screw in extremely osteoporotic (0.18±0.11 kN), osteoporotic (0.37±0.14 kN), and normal (0.97±0.4 kN) cadaver vertebra. In the monolayer model, significant differences ( p <0.05) were observed in pullout strength between extremely osteoporotic (0.3±0.02 kN), osteoporotic (0.65±0.12 kN), and normal (0.99±0.04 kN) bone model. However, the bilayer foam model exhibited no significant differences ( p >0.05) in the pullout strength of pedicle screws between osteoporotic (0.85±0.08 kN) and extremely osteoporotic bone models (0.94±0.08 kN), but there was a significant difference ( p <0.05) between osteoporotic (0.94±0.08 kN) and normal bone models (1.19±0.05 kN). There were no significant differences ( p >0.05) in pullout strength between cadaver and bilayer foam model in normal bones. The new synthetic bone model that reflects the contribution of the pedicles to the pullout strength of the pedicle screws could provide a more efficacious means of testing pedicle-screw pullout strength. The bilayer model can match the pullout strength value of normal lumbar vertebra bone whereas the monolayer foam model was able to match that of the extremely osteoporotic lumbar vertebra.
Congenitally absent lumbar pedicle: a reappraisal
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wortzman, G.; Steinhardt, M.I.
1984-09-01
Three patients who had a diagnosis of congenitally absent lumbar pedicle underwent CT examination. Findings showed that each patient had an aberrant hypoplastic pedicle plus a retroisthmic defect in their ipsilateral lamina rather than an absent pedicle. Axial CT was the diagnostic modality of choice; reformated images were of little value. The differential diagnosis to be considered from the findings of plain film radiography includes pediculate thinning, neoplastic disease, neurofibroma, mesodermal dysplasia associated with neurofibromatosis, and vascular anomalies.
Gazelka, Halena M; Welch, Tasha L; Nassr, Ahmad; Lamer, Tim J
2015-05-01
To determine whether the thermal energy associated with lumbar spine radiofrequency neurotomy (RFN) performed near titanium and stainless steel pedicle screws is conducted to the pedicle screws or adjacent tissues, or both, thus introducing potential for thermal damage to those tissues. Cadaver study. Cadaver laboratory equipped with fluoroscopy, surgical spine implements, and radiofrequency generator. No live human subject; a fresh frozen (and thawed) cadaver torso was used for the study. Titanium and stainless steel pedicle screws were placed in the lumbar spine of a fresh frozen cadaver torso with real-time fluoroscopic guidance. Conventional RFN cannula placement was performed at the level of pedicle screws and a control (nonsurgically altered) lumbar level. Neurotomy was performed with conventional radiofrequency lesioning parameters. Temperatures were recorded at multiple sites through thermistor probes. Direct contact of the radiofrequency cannula with the pedicle screws during conventional RFN produced a substantial increase in temperature in the surrounding soft tissues. A small increase in temperature occurred at the same sites at the control level. Titanium and stainless steel pedicle screws are capable of sustaining large increases in temperature when the radiofrequency probe comes in contact with the screw. These results are suggestive that pedicle screws could serve as a possible source of tissue heating and thermal injury during RFN. Wiley Periodicals, Inc.
Individualized 3D printing navigation template for pedicle screw fixation in upper cervical spine
Guo, Fei; Dai, Jianhao; Zhang, Junxiang; Ma, Yichuan; Zhu, Guanghui; Shen, Junjie; Niu, Guoqi
2017-01-01
Purpose Pedicle screw fixation in the upper cervical spine is a difficult and high-risk procedure. The screw is difficult to place rapidly and accurately, and can lead to serious injury of spinal cord or vertebral artery. The aim of this study was to design an individualized 3D printing navigation template for pedicle screw fixation in the upper cervical spine. Methods Using CT thin slices data, we employed computer software to design the navigation template for pedicle screw fixation in the upper cervical spine (atlas and axis). The upper cervical spine models and navigation templates were produced by 3D printer with equal proportion, two sets for each case. In one set (Test group), pedicle screws fixation were guided by the navigation template; in the second set (Control group), the screws were fixed under fluoroscopy. According to the degree of pedicle cortex perforation and whether the screw needed to be refitted, the fixation effects were divided into 3 types: Type I, screw is fully located within the vertebral pedicle; Type II, degree of pedicle cortex perforation is <1 mm, but with good internal fixation stability and no need to renovate; Type III, degree of pedicle cortex perforation is >1 mm or with the poor internal fixation stability and in need of renovation. Type I and Type II were acceptable placements; Type III placements were unacceptable. Results A total of 19 upper cervical spine and 19 navigation templates were printed, and 37 pedicle screws were fixed in each group. Type I screw-placements in the test group totaled 32; Type II totaled 3; and Type III totaled 2; with an acceptable rate of 94.60%. Type I screw placements in the control group totaled 23; Type II totaled 3; and Type III totaled 11, with an acceptable rate of 70.27%. The acceptability rate in test group was higher than the rate in control group. The operation time and fluoroscopic frequency for each screw were decreased, compared with control group. Conclusion The individualized 3D printing navigation template for pedicle screw fixation is easy and safe, with a high success rate in the upper cervical spine surgery. PMID:28152039
Individualized 3D printing navigation template for pedicle screw fixation in upper cervical spine.
Guo, Fei; Dai, Jianhao; Zhang, Junxiang; Ma, Yichuan; Zhu, Guanghui; Shen, Junjie; Niu, Guoqi
2017-01-01
Pedicle screw fixation in the upper cervical spine is a difficult and high-risk procedure. The screw is difficult to place rapidly and accurately, and can lead to serious injury of spinal cord or vertebral artery. The aim of this study was to design an individualized 3D printing navigation template for pedicle screw fixation in the upper cervical spine. Using CT thin slices data, we employed computer software to design the navigation template for pedicle screw fixation in the upper cervical spine (atlas and axis). The upper cervical spine models and navigation templates were produced by 3D printer with equal proportion, two sets for each case. In one set (Test group), pedicle screws fixation were guided by the navigation template; in the second set (Control group), the screws were fixed under fluoroscopy. According to the degree of pedicle cortex perforation and whether the screw needed to be refitted, the fixation effects were divided into 3 types: Type I, screw is fully located within the vertebral pedicle; Type II, degree of pedicle cortex perforation is <1 mm, but with good internal fixation stability and no need to renovate; Type III, degree of pedicle cortex perforation is >1 mm or with the poor internal fixation stability and in need of renovation. Type I and Type II were acceptable placements; Type III placements were unacceptable. A total of 19 upper cervical spine and 19 navigation templates were printed, and 37 pedicle screws were fixed in each group. Type I screw-placements in the test group totaled 32; Type II totaled 3; and Type III totaled 2; with an acceptable rate of 94.60%. Type I screw placements in the control group totaled 23; Type II totaled 3; and Type III totaled 11, with an acceptable rate of 70.27%. The acceptability rate in test group was higher than the rate in control group. The operation time and fluoroscopic frequency for each screw were decreased, compared with control group. The individualized 3D printing navigation template for pedicle screw fixation is easy and safe, with a high success rate in the upper cervical spine surgery.
Laparoscopic transverse rectus abdominus flap delay for autogenous breast reconstruction.
Kaddoura, I L; Khoury, G S
1998-01-01
Laparoscopic ligation of the deep and superficial inferior epigastric vessels was done for ten mastectomized patients who elected to have autogenous reconstruction of their breast. All these patients had at least one indication for the delay which included obesity, smoking, or requirement of a large volume of tissue for their reconstruction. The procedure did not add any morbidity or mortality to our patients and was found to be comparable to the "open" delay in preventing partial tissue loss in all but two patients. We describe the use of a minimally invasive procedure to augment the deep superior epigastric pedicled blood supply for the future transverse rectus abdominus flap. We have found in laparoscopic delay a safe, short procedure that is useful in high risk patients who choose the option of autologous breast reconstruction.
Extensive Necrosis After Radiation for Cancer: Experiences in Surgical Management
DOE Office of Scientific and Technical Information (OSTI.GOV)
BENNETT, JAMES E.
1963-06-01
Radionecrosis in skin and deeper tissues and its surgical repair are described in 16 cases. The observed epithelial changes included both atrophy and hypertrophy, but atrophy was the dominant feature. Epidermal hypertrophy, which preceded malignant change, developed more slowly and was less likely to occur in areas subjected to deep irradiation than in skin treated with multiple small doses of x-ray over a long period. The indolent ulceration that developed in skin augmented the changes in underlying tissues so that successful management of these ulcerations required adequate excision of the damaged area and replacement with fat-bearing pedicle flap tissue. Whenmore » adjacent flaps were used, permanent blood supply to the region was assured. In cases of radiotherapy for basal cell carcinoma of the scalp, skin necrosis resulted in skull exposure with subsequent osteomyelitis and/or bone necrosis. Excision included the full thickness of the skull, and pedicle flap tissue from the scalp was used for coverage. Cranioplasty was performed after good skin and soft tissue cover had been obtained. Therapeutic radiation of the neck invariably produces marked skin changes, and when ulceration occurs, the vulnerability of underlying structures demands surgical treatment. Lesions of the upper extremity can be excised and covered with direct pedicle flaps from the trunk. Therapeutic radiation of the retroperitoneal area may produce extensive visceral damage as well as injury to the anterior abdominal wall, and anterior suprapubic ulcerations are particularly difficult to deal with since mobile adjacent tissue is scarce. The avascular midline is a limiting factor in flap design. Abdominal flaps extending onto the thigh can be used, but these require multiple delaying procedures to insure adequate blood supply. Patients being managed by these procedures are described. Most patients underwent their operative procedures with few serious complications. While postoperative bleeding and infection are inherent hazards, most complications were traceable to errors in planning or in operative technique. When the primary procedure fails, it is often many weeks before the wound is again ready for coverage and the availability of adjacent tissue has been compromised by the operation. Therefore, it is necessary to mobilize generous amounts of normal tissue to replace the area of injury, for this may be considerably more extensive than external inspection suggests. In addition, retraction of the wound edges following excision can be considerable since surrounding normal tissue may be drawn toward the area of involvement by scar contracture. When transposition or distant pedicle flaps are used, the flaps must be designed initially to allow for coverage of the eventual wound. However, when adjacent flaps are used, they may be outlined at the beginning of the procedure and appropriate alterations are then made, as necessary, after excision of the area of involvement. It is concluded that operation is not advisable until there is pain or ulceration in the region of radiation injury. Preferred treatment consists of excision of all damaged tlssue with pedicle flap replacement.« less
Thoracic Aortic Stent-Graft Placement for Safe Removal of a Malpositioned Pedicle Screw
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hu Hongtao; Shin, Ji Hoon, E-mail: jhshin@amc.seoul.kr; Hwang, Jae-Yeon
2010-10-15
We describe a case of percutaneous placement of a thoracic aortic stent-graft for safe removal of a malpositioned pedicle screw in a 52-year-old man. The patient had undergone posterior thoracic spinal instrumentation for pyogenic spondylitis and spinal deformity 8 months previously. Follow-up CT images showed a malpositioned pedicle screw which was abutting the thoracic aorta at the T5 level. After percutaneous stent-graft placement, the malpositioned pedicle screw was safely and successfully removed.
Smith, Brandon W; Joseph, Jacob R; Kirsch, Michael; Strasser, Mary Oakley; Smith, Jacob; Park, Paul
2017-08-01
OBJECTIVE Percutaneous pedicle screw insertion (PPSI) is a mainstay of minimally invasive spinal surgery. Traditionally, PPSI is a fluoroscopy-guided, multistep process involving traversing the pedicle with a Jamshidi needle, placement of a Kirschner wire (K-wire), placement of a soft-tissue dilator, pedicle tract tapping, and screw insertion over the K-wire. This study evaluates the accuracy and safety of PPSI with a simplified 2-step process using a navigated awl-tap followed by navigated screw insertion without use of a K-wire or fluoroscopy. METHODS Patients undergoing PPSI utilizing the K-wire-less technique were identified. Data were extracted from the electronic medical record. Complications associated with screw placement were recorded. Postoperative radiographs as well as CT were evaluated for accuracy of pedicle screw placement. RESULTS Thirty-six patients (18 male and 18 female) were included. The patients' mean age was 60.4 years (range 23.8-78.4 years), and their mean body mass index was 28.5 kg/m 2 (range 20.8-40.1 kg/m 2 ). A total of 238 pedicle screws were placed. A mean of 6.6 pedicle screws (range 4-14) were placed over a mean of 2.61 levels (range 1-7). No pedicle breaches were identified on review of postoperative radiographs. In a subgroup analysis of the 25 cases (69%) in which CT scans were performed, 173 screws were assessed; 170 (98.3%) were found to be completely within the pedicle, and 3 (1.7%) demonstrated medial breaches of less than 2 mm (Grade B). There were no complications related to PPSI in this cohort. CONCLUSIONS This streamlined 2-step K-wire-less, navigated PPSI appears safe and accurate and avoids the need for radiation exposure to surgeon and staff.
Kaartinen, Ilkka S; Vuento, Maarit H; Hyöty, Marja K; Kallio, Jukka; Kuokkanen, Hannu O
2015-01-01
Total pelvic exenteration (TPE) is a rare operation in which the pelvic contents are removed entirely. Several options for pelvic floor and vaginal reconstruction have been described including transverse rectus abdominis musculocutaneous (TRAM) or deep inferior epigastric perforator (DIEP) flaps. The transverse musculocutaneous gracilis (TMG) flap has been introduced for breast reconstruction as a free flap. We adopted the pedicled TMG flap for reconstructions after TPE. To the best of our knowledge, this is the first report of this method in the literature. Between November 2011 and February 2014, 12 patients underwent TPE and reconstruction with unilateral (six patients) or bilateral (six patients) pedicled TMG flaps. Five patients underwent vaginal reconstruction with bilateral TMG flaps. We describe the operative procedure and the outcome of the operation in these patients. The total mean operative times for TPE with or without vaginal reconstruction were 467 ± 12 and 386 ± 59 min, respectively. The TMG flaps had enough vascular tissue and mobility for reconstructing the TPE defects. There was distal edge necrosis in one out of 18 flaps, while the rest survived completely. During the follow-up, complete wound healing with no signs of weakening of the pelvic floor was observed in all cases. Soft-tissue reconstructions are needed to reduce complications associated with TPE, to secure the pelvic floor and to reconstruct the vagina in select patients. The TMG flap is a logical flap choice that does not lead to functional deficits, complicate the abdominal ostomies or weaken the abdominal wall. It reduces the length of operation compared to that of abdominal flaps. IV, therapeutic. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Sværdborg, Mille; Damsgaard, Tine Engberg
2013-11-01
Many different approaches have been used to minimize the risk of bulge or hernia formation when using autologous abdominal tissue for breast reconstruction. Studies have shown that further reinforcement of the abdominal wall using a mesh may decrease the complication rate.The current study included 40 consecutive patients having unilateral breast reconstruction with the pedicled transverse rectus abdominus musculocutaneous flap. The defect in the abdominal fascia was closed primarily and further reinforced using a Prolene mesh (Ethicon), n = 20, or using a self-fixating Parietex ProGrip mesh (Covidien), n = 20. The patients were examined at an outpatient consultation, with a minimum follow-up of 1 year and questioned about donor-site symptoms using a standardized questionnaire.Of the 20 patients in the Prolene group, 2 (10%) developed abdominal wall bulging, and of the 20 patients in the ProGrip group, 11 (55%) developed abdominal wall bulging (P = 0.006). In both the Prolene and the ProGrip group, most patients reported having continued donor-site symptoms at the time of the follow-up (70% and 80%, respectively); 15% and 30%, respectively, reported having symptoms that influenced their daily or physical activities (not a significant difference). All but 1 patient in our study reported being very happy with the reconstruction and would have done it again, had they known what they did at the time of the follow-up.We conclude that the self-gripping properties of the Parietex ProGrip mesh are not sufficient in withstanding the abdominal wall tension at the donor site after transverse rectus abdominus musculocutaneous-flap harvest and do not recommend using the Parietex ProGrip mesh without fixating sutures for this procedure.
Alaraj, Ali; Charbel, Fady T.; Birk, Daniel; Tobin, Mathew; Luciano, Cristian; Banerjee, Pat P.; Rizzi, Silvio; Sorenson, Jeff; Foley, Kevin; Slavin, Konstantin; Roitberg, Ben
2013-01-01
Recent studies have shown that mental script-based rehearsal and simulation-based training improves the transfer of surgical skills in various medical disciplines. Despite significant advances in technology and intraoperative techniques over the last several decades, surgical skills training on neurosurgical operations still carries significant risk of serious morbidity or mortality. Potentially avoidable technical errors are well recognized as contributing to poor surgical outcome. Surgical education is undergoing overwhelming change, with reduction of working hours and current trends to focus on patient’s safety and linking reimbursement with clinical outcomes, and there is a need for adjunctive means for neurosurgical training;this has been recent advancement in simulation technology. ImmersiveTouch (IT) is an augmented reality (AR) system that integrates a haptic device and a high-resolution stereoscopic display. This simulation platform utilizes multiple sensory modalities, recreating many of the environmental cues experienced during an actual procedure. Modules available include ventriculostomy, bone drilling, percutaneous trigeminal rhizotomy, in addition to simulated spinal modules such as pedicle screw placement, vertebroplasty, and lumbar puncture. We present our experience with development of such AR neurosurgical modules and the feedback from neurosurgical residents. PMID:23254799
Electromechanical actuator for the tongs of a servomanipulator
Martin, H. Lee; Killough, Stephen M.
1986-01-01
Computer-augmented electromechanical system is provided for controlling the tongs of a servomanipulator. The mechanical tongs are motor-driven through the remote slave arm of the manipulator, and the motor control current is supplied by a position sensor which senses the position of a spring-loaded trigger in the master arm handle on the manipulator. The actuator for the tongs provides the operator with artificial force reflection in a unilateral force-force control loop.
Comprehensive Nuclear-Test-Ban Treaty: Updated ’Safeguards’ and Net Assessments
2009-06-03
measures that this nation can take unilaterally within the treaty to protect its nuclear security. To compensate for “disadvantages and risk” they...and strategic forces, and could be augmented with implementation measures . While Safeguards may be part of a future CTBT debate, both supporters and...A second path involves efforts to alter the net assessment through measures intended to mitigate perceived risks of the treaty. This path has been
Nguyen, The Hoang; Kloeppel, Marcus; Staudenmaier, Rainer; Werner, Jürgen; Biemer, Edgar
2005-01-01
Use of an isolated artery as an implanted pedicle in prefabricated flaps has rarely been reported either clinically or experimentally. In Chinchilla Bastard rabbits (n = 36), we dissected an isolated arterial pedicle from the femoral and saphenous artery, anastomosed it end-to-end to the femoral vein at the inguinal ligament and created an isolated arterial loop pedicle. This was implanted and fixed with polyglactin 9/0 under a random-pattern vascularised abdominal fasciocutaneous flap. The neovascularisation in the prefabricated flaps was evaluated macroscopically, by blood analysis, selective microangiography, and histology. The results showed a progressive degree of neovascularisation that corresponded to the increasing length of time that the pedicle was implanted in the flaps. Twenty days after prefabrication, the abdominal fasciocutaneous flap was readily perfused by the blood supply from the arterial pedicle. The capacity of the vessels in this group as seen on angiograms had increased to 258 vessels (108%) compared with the control group (239 vessels, 100%).
Failure of the lumbar pedicles under bending loading - biomed 2010.
Arregui-Dalmases, Carlos; Ash, Joseph H; Del Pozo, Eduardo; Kerrigan, Jason R; Crandall, Jeff
2010-01-01
The purpose of this study was to investigate the magnitude of bending moment that results in fracture of the pedicles when lumbar vertebrae are loaded in four-point bending. Nine human second lumbar vertebrae (L2) were harvested from donors aged 59-75 years. The specimens were potted and then subjected to quasi-static sagittal-plane four-point bending, which allowed for a constant bending moment applied over a 3.8 cm span centered on the vertebral pedicles until fracture. The failure bending moment calculated for the pedicles varied widely (30.7 +/- 12.3 Nm) and was poorly correlated with subject age (y = -0.91x + 91.5, R(2) = -0.27). With increasing displacement, the bending moment applied to the pedicles increased, first linearly, followed by a non-linear portion, prior to specimen fracture. In general, the specimens failed at the interface of the pedicles and vertebral bodies, but failures were observed elsewhere as well. These data provide sufficient response and boundary condition information for finite element modeling and model validation.
Davis, Colin M; Grant, Caroline A; Pearcy, Mark J; Askin, Geoffrey N; Labrom, Robert D; Izatt, Maree T; Adam, Clayton J; Little, J Paige
2017-03-01
Adolescent idiopathic scoliosis is a complex three-dimensional deformity of the spine characterized by deformities in the sagittal, coronal, and axial planes. Spinal fusion using pedicle screw instrumentation is a widely used method for surgical correction in severe (coronal deformity, Cobb angle > 45°) adolescent idiopathic scoliosis curves. Understanding the anatomic difference in the pedicles of patients with adolescent idiopathic scoliosis is essential to reduce the risk of neurovascular or visceral injury through pedicle screw misplacement. To use CT scans (1) to analyze pedicle anatomy in the adolescent thoracic scoliotic spine comparing concave and convex pedicles and (2) to assess the intra- and interobserver reliability of these measurements to provide critical information to spine surgeons regarding size, length, and angle of projection. Between 2007 and 2009, 27 patients with adolescent idiopathic scoliosis underwent thoracoscopic anterior correction surgery by two experienced spinal surgeons. Preoperatively, each patient underwent a CT scan as was their standard of care at that time. Twenty-two patients (mean age, 15.7 years; SD, 2.4 years; range, 11.6-22 years) (mean Cobb angle, 53°; SD, 5.3°; range, 42°-63°) were selected. Inclusion criteria were a clinical diagnosis of adolescent idiopathic scoliosis, female, and Lenke type 1 adolescent idiopathic scoliosis with the major curve confined to the thoracic spine. Using three-dimensional image analysis software, the pedicle width, inner cortical pedicle width, pedicle height, inner cortical pedicle height, pedicle length, chord length, transverse pedicle angle, and sagittal pedicle angles were measured. Randomly selected scans were remeasured by two of the authors and the reproducibility of the measurement definitions was validated through limit of agreement analysis. The concave pedicle widths were smaller compared with the convex pedicle widths at T7, T8, and T9 by 37% (3.44 mm ± 1.16 mm vs 4.72 mm ± 1.02 mm; p < 0.001; mean difference, 1.27 mm; 95% CI, 0.92 mm-1.62 mm), 32% (3.66 mm ± 1.00 mm vs 4.82 mm ± 1.10 mm; p < 0.001; mean difference, 1.16 mm; 95% CI, 0.84 mm-1.49 mm), and 25% (4.10 mm ± 1.57 mm vs 5.12 mm ± 1.17 mm; p < 0.001; mean difference, 1.02 mm; 95% CI, 0.66 mm-1.39 mm), respectively. The concave pedicle heights were smaller than the convex at T5 (9.43 mm ± 0.98 vs 10.63 mm ± 1.10 mm; p = 0.002; mean difference, 1.02 mm; 95% CI, 0.59 mm-1.45 mm), T6 (8.87 mm ± 1.37 mm vs 10.88 mm ± 0.81 mm; p < 0.001; mean difference, 2.02 mm; 95% CI, 1.40 mm-2.63 mm), T7 (9.09 mm ± 1.24 mm vs 11.35 mm ± 0.84 mm; p < 0.001; mean difference, 2.26 mm; 95% CI, 1.81 mm-2.72 mm), and T8 (10.11 mm ± 1.05 mm vs 11.86 mm ± 0.88 mm; p < 0.001; mean difference, 1.75 mm; 95% CI, 1.30 mm-2.19 mm). Conversely, the concave transverse pedicle angle was larger than the convex at levels T6 (11.37° ± 4.48° vs 8.82° ± 4.31°; p = 0.004; mean difference, 2.54°; 95% CI, 1.10°-3.99°), T7 (12.69° ± 5.93° vs 8.65° ± 3.79°; p = 0.002; mean difference, 4.04°; 95% CI, 1.90°-6.17°), T8 (13.24° ± 5.28° vs 7.66° ± 4.87°; p < 0.001; mean difference, 5.58°; 95% CI, 2.99°-8.17°), and T9 (19.95° ± 5.69° vs 8.21° ± 4.02°; p < 0.001; mean difference, 4.74°; 95% CI, 2.68°-6.80°), indicating a more posterolateral to anteromedial pedicle orientation. There is clinically important asymmetry in the morphologic features of pedicles in individuals with adolescent idiopathic scoliosis. The concave side of the curve compared with the convex side is smaller in height and width periapically. Furthermore, the trajectory of the pedicle is more acute on the convex side of the curve compared with the concave side around the apex of the curve. Knowledge of these anatomic variations is essential when performing scoliosis correction surgery to assist with selecting the correct pedicle screw size and trajectory of insertion to reduce the risk of pedicle wall perforation and neurovascular injury.
Coleman, Roger R; Thomas, I Walker
2004-01-01
One use of the anteroposterior lumbar radiograph is to determine axial (y-axis) rotation of the lumbar vertebrae. Rotation might be an element of interest to clinicians seeking to evaluate vertebral positioning. Correlate and quantify movements of the projected pedicles relative to the projected vertebral body during axial rotation and determine if vertebral asymmetry and changes in object film distance affect these movements. A three-dimensional computer model of the fourth and fifth lumbar vertebrae, a modeled radiograph source, and a modeled film were produced. The vertebral model was placed in various degrees of axial rotation at a number of different object film distances. Lines from the source were passed through the pedicles of the fourth lumbar vertebral model and additional lines erected tangent to the lateral body margins. These lines were extended to points of contact with the modeled film. The projected pedicles move relative to the projected vertebral body during y-axis rotation. Vertebral asymmetry and object film distances can also affect the distance of the projected pedicle relative to the projected lateral body margin. Axial rotation produces movement of the projected pedicles relative to the projected vertebral body. However, vertebral asymmetry and changes in object film distance also affect the position of the projected pedicles relative to the projected lateral body margin and might serve as confounders to the clinician seeking to analyze vertebral rotation through the use of the projected pedicles.
Lee, J H; Lee, J-H; Park, J W; Shin, Y H
2012-01-01
In patients with osteoporosis there is always a strong possibility that pedicle screws will loosen. This makes it difficult to select the appropriate osteoporotic patient for a spinal fusion. The purpose of this study was to determine the correlation between bone mineral density (BMD) and the magnitude of torque required to insert a pedicle screw. To accomplish this, 181 patients with degenerative disease of the lumbar spine were studied prospectively. Each underwent dual-energy x-ray absorptiometry (DEXA) and intra-operative measurement of the torque required to insert each pedicle screw. The levels of torque generated in patients with osteoporosis and osteopenia were significantly lower than those achieved in normal patients. Positive correlations were observed between BMD and T-value at the instrumented lumbar vertebrae, mean BMD and mean T-value of the lumbar vertebrae, and mean BMD and mean T-value of the proximal femur. The predictive torque (Nm) generated during pedicle screw insertion was [-0.127 + 1.62 × (BMD at the corresponding lumbar vertebrae)], as measured by linear regression analysis. The positive correlation between BMD and the maximum torque required to insert a pedicle screw suggests that pre-operative assessment of BMD may be useful in determining the ultimate strength of fixation of a device, as well as the number of levels that need to be fixed with pedicle screws in patients who are suspected of having osteoporosis.
Infection following percutaneous vertebral augmentation with polymethylmethacrylate.
Park, Jae-Woo; Park, Sang-Min; Lee, Hui Jong; Lee, Choon-Ki; Chang, Bong-Soon; Kim, Hyoungmin
2018-04-27
Although the incidence of infection following vertebroplasty or kyphoplasty is rare, postoperative infection and cement augmentation in preexistent spondylitis can cause life-threatening complications in frail patients with notable comorbidities. In such cases, urgent culture and biopsy and the long-term use of proper antibiotics are necessary. Infection following vertebral augmentation with polymethylmethacrylate (PMMA) is rare. We aimed to analyze 11 cases of pyogenic spondylitis and spondylodiscitis that occurred after vertebroplasty or kyphoplasty and to review similar cases in the literature. All cases of postoperative spinal infections in our institution between January 2005 and November 2016 that primarily underwent percutaneous vertebroplasty or kyphoplasty were retrospectively reviewed. Eleven patients (mean age 76.3 years) were included. The incidence of infection following vertebroplasty/kyphoplasty was 0.36%. Postoperative infection occurred in 3 of 826 cases. All patients underwent combined surgical and antibiotic treatment because of neurologic deficit on the initial diagnosis of the infection or failure of prior medical treatment of the infection. The surgical procedure was thorough debridement of infected tissue and material including PMMA following anterior column reconstruction via anterior/posterior/combined approach in 10 patients and percutaneous pedicle screw fixation alone in 1 patient aged 96 years. The mean follow-up period was 21.1 months after the revision operation, excluding one patient who died 17 days after revision surgery. Ten patients recovered from infection. Although the incidence of infection following vertebroplasty or kyphoplasty is rare, postoperative infection and cement augmentation in preexisting spondylitis can develop into a life-threatening complication in frail patients with notable comorbidities. In treating infected vertebroplasty and kyphoplasty, immediate culture and biopsy and the long-term use of proper antibiotics are critical. Prompt surgical treatment should be considered in case of significant neurologic deficit, severe instability due to infected fracture, and resistance to antibiotics.
Anatomy of vastus lateralis muscle flap.
Tayfur, Volkan; Magden, Orhan; Edizer, Mete; Atabey, Atay
2010-11-01
A vastus lateralis muscle flap is used as a pedicled and free flap. In this study, the vastus lateralis muscles of 15 adult formalin-fixed cadavers (30 cases) were dissected. The dominant pedicle was found to be descending branch of the lateral circumflex femoral artery. The mean diameter of the artery was found to be 2.1 mm. This pedicle was located 119.4 mm distal to the pubic symphysis. The mean length of the major pedicle was found to be 56.8 mm when the dominant pedicle was chosen to nourish the flap. The dominant pedicle entered the muscle 155.8 and 213.7 mm from the greater trochanter and the anterior superior iliac spine, respectively. The muscle had proximal minor pedicles from the ascending and transverse branches of lateral circumflex femoral artery. These arteries had mean diameters of 1.8 and 2.0 mm, respectively. The distal minor branches were present in all of the dissections. The distal branch had a mean diameter of 1.8 mm. The origin of this distal branch was located 83.7 mm proximal to the intercondylar line. The motor nerve of the vastus lateralis was found to be originating from femoral nerve. The nerve entered the muscle 194.6 mm from the anterior superior iliac spine.
Buchowski, Jacob M; Bridwell, Keith H; Lenke, Lawrence G; Good, Christopher R
2009-06-01
Case report. In order to demonstrate the dangers of intrapedicular application of a hemostatic gelatin matrix to decrease blood loss during pedicle screw insertion, we present 2 patients who--as a result of inadvertent extravasation of the matrix into the spinal canal--developed epidural spinal cord compression (ESCC) requiring emergent decompression. Variety of hemostatic agents can control bleeding during pedicle screw insertion. We have often used a hemostatic gelatin matrix to decrease bleeding from cannulated pedicles by injecting the material into the pedicle after manually palpating the pedicle. Medical records and radiographic studies of 2 patients with AIS who underwent surgical treatment of their deformity and developed a neurologic deficit due to extravasation of FloSeal were reviewed. A 15 year-old male underwent T4 to L2 posterior spinal fusion (PSF). During pedicle screw insertion, a change in NMEPs and SSEPs was noted. A wake-up test confirmed bilateral LE paraplegia. Screws were removed and no perforations were noted on manual palpation. MRI showed T7 to T10 ESCC. He underwent a T5 to T10 laminectomy and hemostatic gelatin matrix noted in the canal and was evacuated. He was ambulatory at 2 weeks and by 3 months he had complete recovery. The second patient was a 15 year-old female who underwent T4 to L1 PSF. Following screw insertion, deterioration in NMEPs and SSEPs was noted. Screws were removed and SCM data returned to baseline. Except for 3 screws that had an inferior breach (Left T7 and Bilateral T8), screws were reinserted and remainder of the surgery was uneventful. Postoperative examination was normal initially but 2 days later, she developed left LE numbness/weakness. Implants were removed and MRI showed T4 to T9 ESCC.She underwent a left (concave) T4 to T9 hemilaminectomy. Hemostatic gelatin matrix was noted and was evacuated. Six weeks following surgery, she had a complete neurologic recovery. The use of a hemostatic gelatin matrix to decrease bleeding from cannulated pedicles during pedicle screw insertion can result in inadvertent extravasation into the spinal canal resulting in ESCC even in the absence of an apparent medial pedicle breach. Given the dangers associated with the technique, we recommend that gelatin matrix products be used judiciously during pedicle screw insertion.
Boon Tow, Benjamin Phak; Yue, Wai Mun; Srivastava, Abhishek; Lai, Jenn Ming; Guo, Chang Ming; Wearn Peng, Benedict Chan; Chen, John L T; Yew, Andy K S; Seng, Chusheng; Tan, Seang Beng
2015-10-01
This was a prospective, nonrandomized study. To assess the accuracy of O-arm navigation-based pedicle screw insertion in lumbar degenerative spondylolisthesis and to compare it with free-hand pedicle screw insertion technique in matched population. O-arm navigation is latest in navigation technology that can provide real-time intraoperative images in 3 dimensions while placing the pedicle screws to improve intraoperative pedicle screw accuracy. Degenerative lumbar spondylolisthesis is a locally unstable pathology and placement of pedicle screws can cause increased rotation and translation of the vertebral body. However, is this motion detected by the tracker placed across the unstable segment, is a matter of debate. Inability to detect these positional changes can lead to pedicle perforation while inserting screws using navigation. No study has evaluated the role of O-arm navigation in this patient population. The study population was divided into 2 groups with 19 patients each, one comprising patients who underwent O-arm navigation-based pedicle screw insertion (group 1) and the other comprising patients who underwent free-hand pedicle screw insertion technique (group 2). A total of 152 pedicle screws were implanted in 38 patients for 1-level instrumented fusion for degenerative lumbar spondylolisthesis. Intraoperative 3-dimensional computed tomography scans using the O-arm were obtained for all patients after insertion of pedicle screws. The images were reviewed intraoperatively and postoperatively for the analysis of pedicle breaches. Assessments in either of the group included (i) accuracy of placement of screws; (ii) the rate and direction of perforation; and (iii) the number of segments the perforated screw was away from the navigation tracker. Mean age of patients in group 1 (O-arm navigation-assisted) was 60 years (SD 11.25; range, 37-73 y), whereas in group 2 (free-hand pedicle screw) was 62 years (SD 18.07; range, 36-90 y). Overall anatomic perforation rate was 12.5% (19/152). Individually, group 1 had 14.47% (11/76) of perforations in comparison with 10.53% (8/76) observed in group 2. The difference was not statistically significant. The lateral margin was the most common site of perforation in both group 1 (64%, 7/11) and group 2 (62.5%, 5/8). Functional perforation rate for the series was 3.3% (5/152), with group 1 having 2.63% (2/76) and group 2 having 3.95% (3/76). The rate of perforation (PR) was significantly higher statistically when the tracker was placed 3 or more [PR 37.5% (6/16)] spinal segments away from instrumented segment compared with when it was placed 1 (0%) or 2 [PR 13.89% (5/36)] spinal segments away. Overall, 11 screws (11/152, 7.24%) had grade 2 perforations and had to be revised. No neurological complications were observed in the series. O-arm navigation does not provide any significant advantage over conventional free-hand pedicle screw insertion technique in patients with single-level degenerative spondylolisthesis. The accuracy is dependent on the distance of the tracker from the level of instrumentation. Lateral perforations are more common because of instability at the instrumented level leading to translation and rotation of the vertebral body while placing pedicle screws leading to preferential lateral trajectory. These lateral perforations could not be prevented by using navigation. However, no significant complications were noted in either technique.
Kong, Xiangxue; Tang, Lei; Ye, Qiang; Huang, Wenhua; Li, Jianyi
2017-11-01
Accurate and safe posterior thoracic pedicle insertion (PTPI) remains a challenge. Patient-specific drill templates (PDTs) created by rapid prototyping (RP) can assist in posterior thoracic pedicle insertion, but pose biocompatibility risks. The aims of this study were to develop alternative PDTs with computer numerical control (CNC) and assess their feasibility and accuracy in assisting PTPI. Preoperative CT images of 31 cadaveric thoracic vertebras were obtained and then the optimal pedicle screw trajectories were planned. The PDTs with optimal screw trajectories were randomly assigned to be designed and manufactured by CNC or RP in each vertebra. With the guide of the CNC- or RP-manufactured PDTs, the appropriate screws were inserted into the pedicles. Postoperative CT scans were performed to analyze any deviations at entry point and midpoint of the pedicles. The CNC group was found to be significant manufacture-time-shortening, and cost-decreasing, when compared with the RP group (P < 0.01). The PDTs fitted the vertebral laminates well while all screws were being inserted into the pedicles. There were no significant differences in absolute deviations at entry point and midpoint of the pedicle on either axial or sagittal planes (P > 0.05). The screw positions were grade 0 in 90.3% and grade 1 in 9.7% of the cases in the CNC group and grade 0 in 93.5% and grade 1 in 6.5% of the cases in the RP group (P = 0.641). CNC-manufactured PDTs are viable for assisting in PTPI with good feasibility and accuracy.
Central pedicled breast reduction technique in male patients after massive weight loss.
Stoff, Alexander; Velasco-Laguardia, Fernando J; Richter, Dirk F
2012-03-01
Male patients after massive weight loss often suffer from redundant skin and soft tissue in the anterior and lateral chest region, causing various deformities of pseudogynecomastia. Techniques with free or pedicled nipple-areola complex (NAC) transposition are widely accepted. The authors present their approach to male breast reduction with preservation of the NAC on a central dermoglandular pedicle and a wide elliptical tissue excision of breast and lateral thorax tissue in combination with liposuction. Male breast reduction was performed on patients after moderate to massive weight loss due to diet or bariatric procedures. Former procedures included free nipple-areola grafts or inferior pedicled techniques for NAC preservation. As a modification, we performed a central pedicled breast reduction on nine male patients with excessive liposuction of the pedicle and a horizontal elliptical skin removal, allowing for sufficient tissue removal at the lateral thorax. From October 2010 until June 2011, nine male patients had central pedicled breast reconstructions after massive weight loss. Mean age was 29.1 years, mean preoperative body mass index was 29.2, and mean preoperative weight loss was 63.9 kg. The chest wall improvement was rated "very good" by eight patients. No major complications occurred in all nine patients. Male chest deformities after massive weight loss can be dealt by several approaches. The optimal scar positioning and the preservation of NAC may be the most challenging aspects of these procedures. Therefore, the preservation of the NAC on a central dermoglandular pedicle with a horizontal submammary scar course may optimize the esthetic outcome.
Tuo, Honglian; Yang, Guangdong; Ling, Dan; Ma, Gang
2010-04-01
To Discuss nasolabial pedicle flap in the repair of facial malignant asal nasi resection defect after clinical practicality and feasibility. Eleven cases of patients with asal nasi surgery in patients with malignant tumor resection. And in accordance with the characteristics of the blood supply of the nasolabial fold area and the size of design defects to be repaired region length. angle and size, design nasolabial flaps pedicled flap face. Go through the nasal alar defect repair defects. All patients were I wound healing, skins all survived, good blood circulation, good color and no obvious scar area. One year postoperative follow-up to 5 years without recurrence of the tumor, the effect of external nose satisfied with the cosmetic restoration. The nasolabial flap pedicled facial blood rich and easy to survive, organizations can provide sufficient volume to the repair of larger nasal defects, vascular pedicle length, the transfer of a flexible, easy to operate and no obvious scar area. Nasolabial pedicle flap to repair the face of larger asal nasi defects after resection of malignant tumors can choose the best skin.
Ipsilateral pedicled TRAM flaps: the safer alternative?
Clugston, P A; Gingrass, M K; Azurin, D; Fisher, J; Maxwell, G P
2000-01-01
Transverse rectus abdominis myocutaneous (TRAM) flap breast reconstruction has become a commonly performed procedure in the 1990s. The original description of the procedure was that of an ipsilaterally based pedicle procedure. Concerns about potential folding of the pedicle with possible compromise of the vascular supply led many surgeons to prefer the contralateral pedicle. Subsequently, there have been several large clinical series of pedicled TRAM flaps showing a relatively high complication rate related to flap vascularity problems. Partial flap necrosis rates in pedicled TRAM series range from 5 to 44 percent. These findings resulted in many centers favoring free TRAM flap breast reconstruction, despite an increase in resource use and negligible differences in complication rates. Ipsilateral pedicle TRAM flap breast reconstruction is not a commonly reported procedure and is reserved for cases for which scars preclude use of the contralateral pedicle. Simplicity and versatility of flap shaping, improved maintenance of the inframammary fold, and lack of disruption of the natural xiphoid hollow give ipsilateral TRAM flaps further advantages. This study reports on a series of 252 consecutive ipsilateral TRAM flap reconstructions in 190 patients. The majority of patients underwent muscle-sparing procedures with preservation of a medial and a lateral strip of rectus muscle. Immediate reconstruction was done in 104 of the 190 patients. Skin-sparing (69 patients) or skin-reduction procedures (21 patients) were used in 90 of the 104 patients (87 percent) undergoing immediate reconstruction. Complication rates were comparable to those of series reported for contralateral TRAM flaps, except that partial flap necrosis (2.0 percent) was less in this series. Risk factors were analyzed with regard to the most common complications seen in this study. Ipsilateral TRAM flap breast reconstruction is our preferred method, if available, because we believe that it has several advantages over the contralateral pedicled TRAM and this report suggests a lower partial flap necrosis rate than previously reported.
Jin, Mengran; Liu, Zhen; Liu, Xingyong; Yan, Huang; Han, Xiao; Qiu, Yong; Zhu, Zezhang
2016-06-01
To assess the accuracy of O-arm-navigation-based pedicle screw insertion in dystrophic scoliosis secondary to NF-1 and compare it with free-hand pedicle screw insertion technique. 32 patients with dystrophic NF-1-associated scoliosis were divided into two groups. A total of 92 pedicle screws were implanted in apical region (two vertebrae above and below the apex each) in 13 patients using O-arm-based navigation (O-arm group), and 121 screws were implanted in 19 patients using free-hand technique (free-hand group). The postoperative CT images were reviewed and analyzed for pedicle violation. The screw penetration was divided into four grades: grade 0 (ideal placement), grade 1 (penetration <2 mm), grade 2 (penetration between 2 and 4 mm), and grade 3 (penetration >4 mm). The accuracy rate of pedicle screw placement (grade 0, 1) was significantly higher in the O-arm group (79 %, 73/92) compared to 67 % (81/121) of the free-hand group (P = 0.045). Meanwhile, a significantly lower prevalence of grade 2-3 perforation was observed in the O-arm group (21 vs. 33 %, P < 0.05), and the incidence of medial perforation was significantly minimized by using O-arm navigation compared to free-hand technique (2 vs. 15 %, P < 0.01). Moreover, the implant density in apical region was significantly elevated by using O-arm navigation (58 vs. 42 %, P < 0.001). We reported 79 % accuracy of O-arm-based pedicle screw placement in dystrophic NF-1-associated scoliosis. O-arm navigation system does facilitate pedicle screw insertion in dystrophic NF-1-associated scoliosis, demonstrating superiorities in the safety and accuracy of pedicle screw placement in comparison with free-hand technique.
Wood, Martin; Mannion, Richard
2011-02-01
A comparison of 2 surgical techniques. To determine the relative accuracy of minimally invasive lumbar pedicle screw placement using 2 different CT-based image-guided techniques. Three-dimensional intraoperative fluoroscopy systems have recently become available that provide the ability to use CT-quality images for navigation during image-guided minimally invasive spinal surgery. However, the cost of this equipment may negate any potential benefit in navigational accuracy. We therefore assess the accuracy of pedicle screw placement using an intraoperative 3-dimensional fluoroscope for guidance compared with a technique using preoperative CT images merged to intraoperative 2-dimensional fluoroscopy. Sixty-seven patients undergoing minimally invasive placement of lumbar pedicle screws (296 screws) using a navigated, image-guided technique were studied and the accuracy of pedicle screw placement assessed. Electromyography (EMG) monitoring of lumbar nerve roots was used in all. Group 1: 24 patients in whom a preoperative CT scan was merged with intraoperative 2-dimensional fluoroscopy images on the image-guidance system. Group 2: 43 patients using intraoperative 3-dimensional fluoroscopy images as the source for the image guidance system. The frequencies of pedicle breach and EMG warnings (indicating potentially unsafe screw placement) in each group were recorded. The rate of pedicle screw misplacement was 6.4% in group 1 vs 1.6% in group 2 (P=0.03). There were no cases of neurologic injury from suboptimal placement of screws. Additionally, the incidence of EMG warnings was significantly lower in group 2 (3.7% vs. 10% (P=0.03). The use of an intraoperative 3-dimensional fluoroscopy system with an image-guidance system results in greater accuracy of pedicle screw placement than the use of preoperative CT scans, although potentially dangerous placement of pedicle screws can be prevented by the use of EMG monitoring of lumbar nerve roots.
The biomechanical consequences of rod reduction on pedicle screws: should it be avoided?
Paik, Haines; Kang, Daniel G; Lehman, Ronald A; Gaume, Rachel E; Ambati, Divya V; Dmitriev, Anton E
2013-11-01
Rod contouring is frequently required to allow for appropriate alignment of pedicle screw-rod constructs. When residual mismatch is still present, a rod persuasion device is often used to achieve further rod reduction. Despite its popularity and widespread use, the biomechanical consequences of this technique have not been evaluated. To evaluate the biomechanical fixation strength of pedicle screws after attempted reduction of a rod-pedicle screw mismatch using a rod persuasion device. Fifteen 3-level, human cadaveric thoracic specimens were prepared and scanned for bone mineral density. Osteoporotic (n=6) and normal (n=9) specimens were instrumented with 5.0-mm-diameter pedicle screws; for each pair of comparison level tested, the bilateral screws were equal in length, and the screw length was determined by the thoracic level and size of the vertebra (35 to 45 mm). Titanium 5.5-mm rods were contoured and secured to the pedicle screws at the proximal and distal levels. For the middle segment, the rod on the right side was intentionally contoured to create a 5-mm residual gap between the inner bushing of the pedicle screw and the rod. A rod persuasion device was then used to engage the setscrew. The left side served as a control with perfect screw/rod alignment. After 30 minutes, constructs were disassembled and vertebrae individually potted. The implants were pulled in-line with the screw axis with peak pullout strength (POS) measured in Newton (N). For the proximal and distal segments, pedicle screws on the right side were taken out and reinserted through the same trajectory to simulate screw depth adjustment as an alternative to rod reduction. Pedicle screws reduced to the rod generated a 48% lower mean POS (495±379 N) relative to the controls (954±237 N) (p<.05) and significantly decreased work energy to failure (p<.05). Nearly half (n=7) of the pedicle screws had failed during the reduction attempt with visible pullout of the screw. After reduction, decreased POS was observed in both normal (p<.05) and osteoporotic (p<.05) bone. Back out and reinsertion of the screw resulted in no significant difference in mean POS, stiffness, and work energy to failure (p>.05). In circumstances where a rod is not fully seated within the pedicle screw, the use of a rod persuasion device decreases the overall POS and work energy to failure of the screw or results in outright failure. Further rod contouring or correction of pedicle screw depth of insertion may be warranted to allow for appropriate alignment of the longitudinal rods. Published by Elsevier Inc.
Martín-Fernández, M; López-Herradón, A; Piñera, A R; Tomé-Bermejo, F; Duart, J M; Vlad, M D; Rodríguez-Arguisjuela, M G; Alvarez-Galovich, L
2017-08-01
Dramatic increases in the average life expectancy have led to increases in the variety of degenerative changes and deformities observed in the aging spine. The elderly population can present challenges for spine surgeons, not only because of increased comorbidities, but also because of the quality of their bones. Pedicle screws are the implants used most commonly in spinal surgery for fixation, but their efficacy depends directly on bone quality. Although polymethyl methacrylate (PMMA)-augmented screws represent an alternative for patients with osteoporotic vertebrae, their use has raised some concerns because of the possible association between cement leakages (CLs) and other morbidities. To analyze potential complications related to the use of cement-augmented screws for spinal fusion and to investigate the effectiveness of using these screws in the treatment of patients with low bone quality. A retrospective single-center study. This study included 313 consecutive patients who underwent spinal fusion using a total of 1,780 cement-augmented screws. We analyzed potential complications related to the use of cement-augmented screws, including CL, vascular injury, infection, screw extraction problems, revision surgery, and instrument failure. There are no financial conflicts of interest to report. A total of 1,043 vertebrae were instrumented. Cement leakage was observed in 650 vertebrae (62.3%). There were no major clinical complications related to CL, but two patients (0.6%) had radicular pain related to CL at the S1 foramina. Of the 13 patients (4.1%) who developed deep infections requiring surgical debridement, two with chronic infections had possible spondylitis that required instrument removal. All patients responded well to antibiotic therapy. Revision surgery was performed in 56 patients (17.9%), most of whom had long construction. A total of 180 screws were removed as a result of revision. There were no problems with screw extraction. These results demonstrate the efficacy and safety of cement-augmented screws for the treatment of patients with low bone mineral density. Copyright © 2017 Elsevier Inc. All rights reserved.
Watanabe, Kei; Yamazaki, Akiyoshi; Hirano, Toru; Izumi, Tomohiro; Sano, Atsuki; Morita, Osamu; Kikuchi, Ren; Ito, Takui
2010-09-15
Case report. To describe an iatrogenic aortic injury by pedicle screw instrumentation during posterior reconstructive surgery of spinal deformity. Iatrogenic major vascular injuries during anterior instrumentation procedures have been reported by several authors, but there have been few reports regarding iatrogenic major vascular injuries during posterior instrumentation procedures. A 57-year-old woman with thoracolumbar kyphosis due to osteoporotic T12 vertebral fracture underwent posterior correction and fusion (T10-L2), using segmental pedicle screw construct concomitant with T12 pedicle subtraction osteotomy. Postoperative routine plain radiographs and computed tomography myelography demonstrated a misplaced left T10 pedicle screw, which was in contact with the posteromedial aspect of the thoracic aorta, and suspected penetration of the aortic wall. The patient underwent removal of the pedicle screw, and repair of the penetrated aortic wall through a simultaneous anterior-posterior approach. The patient tolerated the procedure well without neurologic sequelae, and was discharged several days after removal of a left tube thoracostomy. Plain radiographs demonstrated solid fusion at the osteotomy site and no loosening of hardware. Preoperative neurologic symptoms improved completely at 18-months follow-up. Use of pedicle screw instrumentation has the potential to cause major vascular injury during posterior spinal surgery, and measures to prevent this complication must be taken. Timely diagnosis and treatment are essential to prevent both early and delayed complications and death.
Wang, Fei; Xu, Xi-Ming; Lu, Yanghu; Wei, Xian-Zhao; Zhu, Xiao-Dong; Li, Ming
2016-01-01
Abstract Pedicle screw constructs have become the mainstay for surgical correction in patients with spinal deformities. To reduce or avoid the risk of pedicle screw-based complications and to decrease the costs associated with pedicle screw instrumentation, some authors have introduced interval, skipped, and key-vertebral pedicle screw strategies for correction. However, there have been no comparisons of outcomes among these 3 pedicle screw-placement strategies. The aim of this study was to compare the correlative clinical outcomes of posterior correction and fusion with pedicle screw fixation using these 3 surgical strategies. Fifty-six consecutive patients with Lenke type 1 adolescent idiopathic scoliosis were included in this study. Twenty patients were treated with the interval pedicle screw strategy (IPSS), 20 with the skipped pedicle screw strategy (SPSS), and 16 with the key-vertebral pedicle screw strategy (KVPSS). Coronal and sagittal radiographs were analyzed before surgery, at 1 week after surgery, and at the last follow-up after surgery. There were no significant differences among the 3 groups regarding preoperative radiographic parameters. No significant difference was found between the IPSS and SPSS groups in correction of the main thoracic curve (70.8% vs 70.0%; P = 0.524). However, there were statistically significant differences between the IPSS and KVPSS groups (70.8% vs 64.9%) and between the SPSS and KVPSS groups (70.0% vs 64.9%) in correction of the main thoracic curve (P < 0.001 for both). Additionally, there were no significant differences among the 3 strategies for sagittal parameters at the immediate postoperative and last postoperative follow-up periods, though there were significant differences in the Cobb angle between the preoperative and immediate postoperative periods among the 3 groups, but not between the immediate postoperative and last follow-up periods. The amount of hospital charges in the SPSS group was significantly higher than those in the IPSS (P < 0.001) and KVPSS groups (P < 0.001). There were also significant differences in operative time between the IPSS and KVPSS groups (P < 0.001) and between the SPSS and KVPSS groups (P < 0.001). Each of the 3 types of pedicle screw strategies for correction in patients with Lenke type 1 adolescent idiopathic scoliosis are effective, with satisfactory coronal and acceptable sagittal plane results. Although the KVPSS does not provide superior operative correction compared with the IPSS and SPSS, it can achieve a satisfactory clinical outcome and is more cost-effective. PMID:26962821
Wang, Fei; Xu, Xi-Ming; Lu, Yanghu; Wei, Xian-Zhao; Zhu, Xiao-Dong; Li, Ming
2016-03-01
Pedicle screw constructs have become the mainstay for surgical correction in patients with spinal deformities. To reduce or avoid the risk of pedicle screw-based complications and to decrease the costs associated with pedicle screw instrumentation, some authors have introduced interval, skipped, and key-vertebral pedicle screw strategies for correction. However, there have been no comparisons of outcomes among these 3 pedicle screw-placement strategies.The aim of this study was to compare the correlative clinical outcomes of posterior correction and fusion with pedicle screw fixation using these 3 surgical strategies.Fifty-six consecutive patients with Lenke type 1 adolescent idiopathic scoliosis were included in this study. Twenty patients were treated with the interval pedicle screw strategy (IPSS), 20 with the skipped pedicle screw strategy (SPSS), and 16 with the key-vertebral pedicle screw strategy (KVPSS). Coronal and sagittal radiographs were analyzed before surgery, at 1 week after surgery, and at the last follow-up after surgery.There were no significant differences among the 3 groups regarding preoperative radiographic parameters. No significant difference was found between the IPSS and SPSS groups in correction of the main thoracic curve (70.8% vs 70.0%; P = 0.524). However, there were statistically significant differences between the IPSS and KVPSS groups (70.8% vs 64.9%) and between the SPSS and KVPSS groups (70.0% vs 64.9%) in correction of the main thoracic curve (P < 0.001 for both). Additionally, there were no significant differences among the 3 strategies for sagittal parameters at the immediate postoperative and last postoperative follow-up periods, though there were significant differences in the Cobb angle between the preoperative and immediate postoperative periods among the 3 groups, but not between the immediate postoperative and last follow-up periods. The amount of hospital charges in the SPSS group was significantly higher than those in the IPSS (P < 0.001) and KVPSS groups (P < 0.001). There were also significant differences in operative time between the IPSS and KVPSS groups (P < 0.001) and between the SPSS and KVPSS groups (P < 0.001).Each of the 3 types of pedicle screw strategies for correction in patients with Lenke type 1 adolescent idiopathic scoliosis are effective, with satisfactory coronal and acceptable sagittal plane results. Although the KVPSS does not provide superior operative correction compared with the IPSS and SPSS, it can achieve a satisfactory clinical outcome and is more cost-effective.
Lavelle, William F; Ranade, Ashish; Samdani, Amer F; Gaughan, John P; D'Andrea, Linda P; Betz, Randal R
2014-01-01
Pedicle screws are used increasingly in spine surgery. Concerns of complications associated with screw breach necessitates accurate pedicle screw placement. Postoperative CT imaging helps to detect screw malposition and assess its severity. However, accuracy is dependent on the reading of the CT scans. Inter- and intra-observer variability could affect the reliability of CT scans to assess multiple screw types and sites. The purpose of this study was to assess the reliability of multi-observer analysis of CT scans for determining pedicle screw breach for various screw types and sites in patients with spinal deformity or degenerative pathologies. Axial CT scan images of 23 patients (286 screws) were read by four experienced spine surgeons. Pedicle screw placement was considered 'In' when the screw was fully contained and/or the pedicle wall breach was ≤2 mm. 'Out' was defined as a breach in the medial or lateral pedicle wall >2 mm. Intra-class coefficients (ICC) were calculated to assess the inter- and intra-observer reliability. Marked inter- and intra-observer variability was noticed. The overall inter-observer ICC was 0.45 (95% confidence limits 0.25 to 0.65). The intra-observer ICC was 0.49 (95% confidence limits 0.29 to 0.69). Underlying spinal pathology, screw type, and patient age did not seem to impact the reliability of our CT assessments. Our results indicate the evaluation of pedicle screw breach on CT by a single surgeon is highly variable, and care should be taken when using individual CT evaluations of millimeters of breach as a basis for screw removal. This was a Level III study.
Xu, Wei; Zhang, Xuming; Ke, Tie; Cai, Hongru; Gao, Xiang
2017-08-11
This study aimed to evaluate the application of 3D printing in assisting preoperative plan of pedicle screw placement for treating middle-upper thoracic trauma. A preoperative plan was implemented in seven patients suffering from middle-upper thoracic (T3-T7) trauma between March 2013 and February 2016. In the 3D printing models, entry points of 56 pedicle screws (Magerl method) and 4 important parameters of the pedicle screws were measured, including optimal diameter (ϕ, mm), length (L, mm), inclined angle (α), head-tilting angle (+β), and tail-tilting angle (-β). In the surgery, bare-hands fixation of pedicle screws was performed using 3D printing models and the measured parameters as guidance. A total of seven patients were enrolled, including five men and two women, with the age of 21-62 years (mean age of 37.7 years). The position of the pedicle screw was evaluated postoperatively using a computerized tomography scan. Totally, 56 pedicle screws were placed, including 33 pieces of level 0, 18 pieces of level 1, 4 pieces of level 2 (pierced lateral wall), and 1 piece of level 3 (pierced lateral wall, no adverse consequences), with a fine rate of 91.0%. 3D printing technique is an intuitive and effective assistive technology to pedicle screw fixation for treating middle-upper thoracic vertebrae, which improve the accuracy of bare-hands screw placement and reduce empirical errors. The trial was approved by the Ethics Committee of the Fujian Provincial Hospital. It was registered on March 1st, 2013, and the registration number was K2013-03-001.
Uslu, A; Korkmaz, M A; Surucu, A; Karaveli, A; Sahin, C; Ataman, M G
2018-06-14
Adequate tissue removal must be performed for symptom relief following reduction mammoplasty. However, this is not always possible in patients with gigantomastia because the pedicle is planned wider and the breast cannot be sufficiently reduced to prevent compromising the blood supply to the pedicle. To maximize blood circulation to the nipple-areola complex in our patients, the pedicle was planned to include the internal thoracic artery branches coming from both the second and third interspaces and the intercostal artery branches coming from the fourth and fifth intercostal spaces. A total of 185 patients underwent reduction mammoplasty with the superomedial pedicle- and septal perforator-based technique. The mean weight of excised tissue was 928.77 g from the right breast and 899.92 g from the left, whereas the mean distance of nipple-areola transfer was 11.52 cm on the right breast and 11.27 cm on the left. Complications developed in 11 patients (5.94%): hematoma occurred in three patients, partial loss of areola and fat necrosis in five patients, and wound dehiscence in three patients. The pedicle included vessels of both superomedial and septum origin without any disruption in circulation. Consequently, the blood supply of the nipple-areola complex was preserved. Furthermore, in cases where the pedicle was long, intercostal perforators were identified and the pedicle was narrowed thoroughly; thus, the breast was reduced to the desired volume while minimizing the risk of complications. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Absent pedicles in campomelic dysplasia.
McDowell, Michael M; Dede, Ozgur; Bosch, Patrick; Tyler-Kabara, Elizabeth C
2017-06-01
The objective of the present study is to report a case of campomelic dysplasia illustrating the absence of cervical and thoracic pedicles. This report reiterates the importance of this clinical peculiarity in the setting of spine instrumentation. A 10-year-old female patient with campomelic dysplasia presented with progressive kyphoscoliosis and signs of neural compromise. Imaging studies confirmed thoracic level stenosis and demonstrated absence of multiple pedicles in cervical and thoracic spine. The patient underwent decompression and instrumentation/fusion for her spinal deformity. The patient was instrumented between C2 and L4 with pedicle screws and sublaminar cables. However, pedicle fixation was not possible for the lower cervical and upper-mid thoracic spine. Also, floating posterior elements precluded the use of laminar fixation in the lower cervical spine. Cervicothoracic lumbosacral orthosis (CTLSO) was used for external immobilization to supplement the tenuous fixation in the cervicothoracic area. The patient improved neurologically with no signs of implant failure at the 2-year follow-up. Absence of pedicles and floating posterior elements present a challenge during spine surgery in campomelic dysplasia. Surgeons should prepare for alternative fixation methods and external immobilization when planning on spinal instrumentation in affected patients. Level IV Case Report.
Wood, Martin James; McMillen, Jason
2014-01-01
This study retrospectively assessed the accuracy of placement of lumbar pedicle screws placed by a single surgeon using a minimally-invasive, intra-operative CT-based computer navigated technique in combination with continuous electromyography (EMG) monitoring. The rates of incorrectly positioned screws were reviewed in the context of the surgeon's experience and learning curve. Data was retrospectively reviewed from all consecutive minimally invasive lumbar fusions performed by the primary author over a period of over 4 years from April 2008 until October 2012. All cases that had utilized computer-assisted intra-operative CT-based image guidance and continuous EMG monitoring to guide percutaneous pedicle screw placement were analysed for the rates of malposition of the pedicle screws. Pedicle screw malposition was defined as having occurred if the screw trajectory was adjusted intraoperatively due to positive EMG responses, or due to breach of the pedicle cortex by more than 2mm on intraoperative CT imaging performed at the end of the instrumentation procedure. Further analysis of the data was undertaken to determine if the rates of malposition changed with the surgeon's experience with the technique. Six hundred and twenty-seven pedicle screws were placed in one hundred and fifty patients. The overall rate of intraoperative malposition and subsequent adjustment of pedicle screw placement was 3.8% (24 of 627 screws). Screw malposition was detected by intraoperative CT imaging. Warning of potential screw misplacement was provided by use of the EMG monitoring. With increased experience with the technique, rates of intraoperative pedicle screw malposition were found to decrease from 5.1% of screws in the first fifty patients, to 2.0% in the last 50 patients. Only one screw was suboptimally placed at the end of surgery, which did not result in a neurological deficit. The use of CT-based computer-assisted navigation in combination with continuous EMG monitoring during percutaneous transpedicular screw placement results in very low rates of malposition and neural injury that compare favourably with previously reported rates. Pedicle screw placement accuracy continues to improve as the surgeon becomes more experienced with the technique.
McMillen, Jason
2014-01-01
Objective This study retrospectively assessed the accuracy of placement of lumbar pedicle screws placed by a single surgeon using a minimally-invasive, intra-operative CT-based computer navigated technique in combination with continuous electromyography (EMG) monitoring. The rates of incorrectly positioned screws were reviewed in the context of the surgeon's experience and learning curve. Methods Data was retrospectively reviewed from all consecutive minimally invasive lumbar fusions performed by the primary author over a period of over 4 years from April 2008 until October 2012. All cases that had utilized computer-assisted intra-operative CT-based image guidance and continuous EMG monitoring to guide percutaneous pedicle screw placement were analysed for the rates of malposition of the pedicle screws. Pedicle screw malposition was defined as having occurred if the screw trajectory was adjusted intraoperatively due to positive EMG responses, or due to breach of the pedicle cortex by more than 2mm on intraoperative CT imaging performed at the end of the instrumentation procedure. Further analysis of the data was undertaken to determine if the rates of malposition changed with the surgeon's experience with the technique. Results Six hundred and twenty-seven pedicle screws were placed in one hundred and fifty patients. The overall rate of intraoperative malposition and subsequent adjustment of pedicle screw placement was 3.8% (24 of 627 screws). Screw malposition was detected by intraoperative CT imaging. Warning of potential screw misplacement was provided by use of the EMG monitoring. With increased experience with the technique, rates of intraoperative pedicle screw malposition were found to decrease from 5.1% of screws in the first fifty patients, to 2.0% in the last 50 patients. Only one screw was suboptimally placed at the end of surgery, which did not result in a neurological deficit. Conclusion The use of CT-based computer-assisted navigation in combination with continuous EMG monitoring during percutaneous transpedicular screw placement results in very low rates of malposition and neural injury that compare favourably with previously reported rates. Pedicle screw placement accuracy continues to improve as the surgeon becomes more experienced with the technique. PMID:25694919
Libondi, Guido; Ramakrishnan, Venkat
2017-01-01
Background The transverse upper gracilis (TUG) flap is the senior authors’ second choice for autologous breast reconstruction when the DIEP flap is not available. It provides durable, pliable tissue with well hidden scars. The main criticism of this flap is the limited volume, donor site complications, short pedicle and vessel mismatch depending on which recipient vessels are used. We described methods of reducing vessel mismatch, complications of venous coupler and refinements to help give a more superior aesthetic outcome. Methods We describe several maneuvers to help reduce vessel mismatch with the use of the internal mammary (IM) perforator vessels with a modification of the Harashina fish-mouth technique or the use of a vessel bifurcation to increase vessel diameter. We also describe the optimum method of perforator preparation and potential methods to prevent palpable venous couplers. The author’s describe their case series of 14 TUG flaps to reconstruct 13 breasts in 12 patients. Results Eight unilateral, 2 partial breast reconstruction, 1 bilateral and 1 bilateral TUG flap for a unilateral reconstruction was carried out. All flaps survived with one partial flap necrosis, one donor site seroma and two cases of palpable/tender venous couplers. The mean reconstructed breast was 320 grams. Conclusions The TUG flap is a reconstructive challenge, but with correct planning a good aesthetic outcome is possible. The IM perforator is our first choice recipient vessel in TUG breast reconstructions. With meticulous preparation and by overcoming vessel mismatch the use of this recipient vessel is a reliable option. PMID:28861378
Gong, Xu; Cui, Jianli; Jiang, Ziping; Lu, Laijin; Li, Xiucun
2018-03-01
Few clinical retrospective studies have reported the risk factors of pedicled flap necrosis in hand soft tissue reconstruction. The aim of this study was to identify non-technical risk factors associated with pedicled flap perioperative necrosis in hand soft tissue reconstruction via a multivariate logistic regression analysis. For patients with hand soft tissue reconstruction, we carefully reviewed hospital records and identified 163 patients who met the inclusion criteria. The characteristics of these patients, flap transfer procedures and postoperative complications were recorded. Eleven predictors were identified. The correlations between pedicled flap necrosis and risk factors were analysed using a logistic regression model. Of 163 skin flaps, 125 flaps survived completely without any complications. The pedicled flap necrosis rate in hands was 11.04%, which included partial flap necrosis (7.36%) and total flap necrosis (3.68%). Soft tissue defects in fingers were noted in 68.10% of all cases. The logistic regression analysis indicated that the soft tissue defect site (P = 0.046, odds ratio (OR) = 0.079, confidence interval (CI) (0.006, 0.959)), flap size (P = 0.020, OR = 1.024, CI (1.004, 1.045)) and postoperative wound infection (P < 0.001, OR = 17.407, CI (3.821, 79.303)) were statistically significant risk factors for pedicled flap necrosis of the hand. Soft tissue defect site, flap size and postoperative wound infection were risk factors associated with pedicled flap necrosis in hand soft tissue defect reconstruction. © 2017 Royal Australasian College of Surgeons.
Vaidya, Rahul; Onwudiwe, Ndidi; Roth, Matthew; Sethi, Anil
2013-01-01
Purpose. Comparison of monoaxial and polyaxial screws with the use of subcutaneous anterior pelvic fixation. Methods. Four different groups each having 5 constructs were tested in distraction within the elastic range. Once that was completed, 3 components were tested in torsion within the elastic range, 2 to torsional failure and 3 in distraction until failure. Results. The pedicle screw systems showed higher stiffness (4.008 ± 0.113 Nmm monoaxial, 3.638 ± 0.108 Nmm Click-x; 3.634 ± 0.147 Nmm Pangea) than the exfix system (2.882 ± 0.054 Nmm) in distraction. In failure testing, monoaxial pedicle screw system was stronger (360 N) than exfixes (160 N) and polyaxial devices which failed if distracted greater than 4 cm (157 N Click-x or 138 N Pangea). The exfix had higher peak torque and torsional stiffness than all pedicle systems. In torsion, the yield strengths were the same for all constructs. Conclusion. The infix device constructed with polyaxial or monoaxial pedicle screws is stiffer than the 2 pin external fixator in distraction testing. In extreme cases, the use of reinforcement or monoaxial systems which do not fail even at 360 N is a better option. In torsional testing, the 2 pin external fixator is stiffer than the pedicle screw systems. PMID:24368943
Vaidya, Rahul; Onwudiwe, Ndidi; Roth, Matthew; Sethi, Anil
2013-01-01
Purpose. Comparison of monoaxial and polyaxial screws with the use of subcutaneous anterior pelvic fixation. Methods. Four different groups each having 5 constructs were tested in distraction within the elastic range. Once that was completed, 3 components were tested in torsion within the elastic range, 2 to torsional failure and 3 in distraction until failure. Results. The pedicle screw systems showed higher stiffness (4.008 ± 0.113 Nmm monoaxial, 3.638 ± 0.108 Nmm Click-x; 3.634 ± 0.147 Nmm Pangea) than the exfix system (2.882 ± 0.054 Nmm) in distraction. In failure testing, monoaxial pedicle screw system was stronger (360 N) than exfixes (160 N) and polyaxial devices which failed if distracted greater than 4 cm (157 N Click-x or 138 N Pangea). The exfix had higher peak torque and torsional stiffness than all pedicle systems. In torsion, the yield strengths were the same for all constructs. Conclusion. The infix device constructed with polyaxial or monoaxial pedicle screws is stiffer than the 2 pin external fixator in distraction testing. In extreme cases, the use of reinforcement or monoaxial systems which do not fail even at 360 N is a better option. In torsional testing, the 2 pin external fixator is stiffer than the pedicle screw systems.
Sielska-Badurek, Ewelina M; Sobol, Maria; Jędra, Katarzyna; Rzepakowska, Anna; Osuch-Wójcikiewicz, Ewa; Niemczyk, Kazimierz
2017-09-01
Injection laryngoplasty (glottis augmentation) is the preferred method in surgical management of unilateral vocal fold paralysis (UVFP). Traditionally, these procedures are performed in the operating room. Nowadays, however, these procedures have moved into the office. To evaluate the voice quality after transoral injection laryngoplasty under local anaesthesia in patients with unilateral vocal fold paralysis. Fourteen subjects (5 women and 9 men) with unilateral vocal fold paresis (9 with right vocal fold paresis and 5 with left vocal fold paresis) were included in the study. The mean age of the group was 57.8 ±19.0 years (32-83 years). All of the injection laryngoplasties were performed transorally, under local anaesthesia. The injection material was calcium hydroxylapatite. Before and 1, 3 and 6 months after the procedure the following variables were evaluated: voice perception, videostroboscopy, acoustic analysis, aerodynamic evaluation, and the subjective rating of the voice quality by the patient. After injection laryngoplasty, complete glottal closure was achieved or there was a significant improvement in the glottal closure of each subject. We noted great improvement in the post-injection objective and subjective voice outcomes and patients reported improvement in the voice-related quality of life. The transoral approach for injection laryngoplasty under local anaesthesia is an effective and safe way to treat incomplete glottal closure in patients with UVFP. The transoral approach is an efficient alternative to other surgical techniques used for vocal fold injection.
Sielska-Badurek, Ewelina M.; Jędra, Katarzyna; Rzepakowska, Anna; Osuch-Wójcikiewicz, Ewa; Niemczyk, Kazimierz
2017-01-01
Introduction Injection laryngoplasty (glottis augmentation) is the preferred method in surgical management of unilateral vocal fold paralysis (UVFP). Traditionally, these procedures are performed in the operating room. Nowadays, however, these procedures have moved into the office. Aim To evaluate the voice quality after transoral injection laryngoplasty under local anaesthesia in patients with unilateral vocal fold paralysis. Material and methods Fourteen subjects (5 women and 9 men) with unilateral vocal fold paresis (9 with right vocal fold paresis and 5 with left vocal fold paresis) were included in the study. The mean age of the group was 57.8 ±19.0 years (32–83 years). All of the injection laryngoplasties were performed transorally, under local anaesthesia. The injection material was calcium hydroxylapatite. Before and 1, 3 and 6 months after the procedure the following variables were evaluated: voice perception, videostroboscopy, acoustic analysis, aerodynamic evaluation, and the subjective rating of the voice quality by the patient. Results After injection laryngoplasty, complete glottal closure was achieved or there was a significant improvement in the glottal closure of each subject. We noted great improvement in the post-injection objective and subjective voice outcomes and patients reported improvement in the voice-related quality of life. Conclusions The transoral approach for injection laryngoplasty under local anaesthesia is an effective and safe way to treat incomplete glottal closure in patients with UVFP. The transoral approach is an efficient alternative to other surgical techniques used for vocal fold injection. PMID:29062449
Pedicle distraction increases intervertebral and spinal canal area in a cadaver and bone model
Hughes, Matthew; Papadakos, Nikolaos; Bishop, Tim; Bernard, Jason
2018-01-01
Introduction: Lumbar spinal stenosis is degenerative narrowing of the spinal canal and/or intervertebral foramen causing compression of the spinal cord and nerve roots. Traditional decompression techniques can often cause significant trauma and vertebral instability. This paper evaluates a method of increasing pedicle length to decompress the spinal and intervertebral foramen, which could be done minimally invasive. Methods: Three Sawbone (Sawbones Europe, Sweden) and 1 cadaveric lumbar spine underwent bilateral pedicle distraction at L4. A pedicle channel was drilled between the superior articular process and transverse process into the vertebral body. The pedicles underwent osteotomy at the midpoint. Screws were inserted bilaterally and fixated distraction of 0 mm, 2 mm, 4 mm and 6 mm. CT images were taken at each level of distraction. Foramen area was measured in the sagittal plane at L3/4. Spinal canal area was measured at L4 in the axial images. The cadaver was used to evaluate safety of osteotomy and soft tissue interactions preventing distraction. Statistical analysis was by student paired t-test and Pearson rank test. Results: Increasing distraction led to greater Spinal canal area. From 4.27 cm2 to 5.72 cm2 (p = 0.002) with 6 mm distraction. A Maximal increase of 34.1%. Vertebral foramen area also increased with increasing pedicle distraction. From 2.43 cm2 to 3.22 cm2 (p = 0.022) with 6 mm distraction. A maximal increase of 32.3%. The cadaver spinal canal increased in area by 21.7%. The vertebral foramen increased in area by 36.2% (left) and 22.6% (right). Discussion: For each increase in pedicle distraction the area of the spinal and vertebral foramen increases. Pedicle distraction could potentially be used to alleviate spinal stenosis and root impingement. A potential osteotomy plane could be at the midpoint of the pedicle with minimal risk to nerve roots and soft tissue restrictions to prevent distraction. PMID:29727270
Pedicle distraction increases intervertebral and spinal canal area in a cadaver and bone model.
Hughes, Matthew; Papadakos, Nikolaos; Bishop, Tim; Bernard, Jason
2018-01-01
Lumbar spinal stenosis is degenerative narrowing of the spinal canal and/or intervertebral foramen causing compression of the spinal cord and nerve roots. Traditional decompression techniques can often cause significant trauma and vertebral instability. This paper evaluates a method of increasing pedicle length to decompress the spinal and intervertebral foramen, which could be done minimally invasive. Three Sawbone (Sawbones Europe, Sweden) and 1 cadaveric lumbar spine underwent bilateral pedicle distraction at L4. A pedicle channel was drilled between the superior articular process and transverse process into the vertebral body. The pedicles underwent osteotomy at the midpoint. Screws were inserted bilaterally and fixated distraction of 0 mm, 2 mm, 4 mm and 6 mm. CT images were taken at each level of distraction. Foramen area was measured in the sagittal plane at L3/4. Spinal canal area was measured at L4 in the axial images. The cadaver was used to evaluate safety of osteotomy and soft tissue interactions preventing distraction. Statistical analysis was by student paired t-test and Pearson rank test. Increasing distraction led to greater Spinal canal area. From 4.27 cm 2 to 5.72 cm 2 (p = 0.002) with 6 mm distraction. A Maximal increase of 34.1%. Vertebral foramen area also increased with increasing pedicle distraction. From 2.43 cm 2 to 3.22 cm 2 (p = 0.022) with 6 mm distraction. A maximal increase of 32.3%. The cadaver spinal canal increased in area by 21.7%. The vertebral foramen increased in area by 36.2% (left) and 22.6% (right). For each increase in pedicle distraction the area of the spinal and vertebral foramen increases. Pedicle distraction could potentially be used to alleviate spinal stenosis and root impingement. A potential osteotomy plane could be at the midpoint of the pedicle with minimal risk to nerve roots and soft tissue restrictions to prevent distraction. © The Authors, published by EDP Sciences, 2018.
Yoshihara, Hiroyuki; Abumi, Kuniyoshi; Ito, Manabu; Kotani, Yoshihisa; Sudo, Hideki; Takahata, Masahiko
2013-11-01
Surgical treatment for severe circumferentially fixed cervical kyphosis has been challenging. Both anterior and posterior releases are necessary to provide the cervical mobility necessary for fusion in a corrected position. In two case reports, we describe the circumferential osteotomy of anterior-posterior-anterior surgical sequence, and the efficacy of this technique when cervical pedicle screw fixation for severe fixed cervical kyphosis is used. Etiology of fixed cervical kyphosis was unknown in one patient and neurofibromatosis in one patient. Both patients had severe fixed cervical kyphosis as determined by cervical radiographs and underwent circumferential osteotomy and fixation via an anterior-posterior-anterior surgical sequence and correction of kyphosis by pedicle screw fixation. Severe fixed cervical kyphosis was treated successfully by the use of circumferential osteotomy and pedicle screw fixation. The surgical sequence described in this report is a reasonable approach for severe circumferentially fixed cervical kyphosis and short segment fixation can be achieved using pedicle screws. Copyright © 2013 Elsevier Inc. All rights reserved.
The possibility for use of venous flaps in plastic surgery
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baytinger, V. F., E-mail: baitinger@mail.tomsknet.ru; Kurochkina, O. S., E-mail: kurochkinaos@yandex.ru; Selianinov, K. V.
2015-11-17
The use of venous flaps is controversial. The mechanism of perfusion of venous flaps is still not fully understood. The research was conducted on 56 white rats. In our experimental work we studied two different models of venous flaps: pedicled venous flap (PVF) and pedicled arterialized venous flap (PAVF). Our results showed that postoperative congestion was present in all flaps. However 66.7% of all pedicled venous flaps and 100% of all pedicled arterialized venous flaps eventually survived. Histological examination revealed that postoperatively the blood flow in the skin of the pedicled arterialized venous flap became «re-reversed» again; there were nomore » differences between mechanism of survival of venous flaps and other flaps. On the 7-14th day in the skin of all flaps were processes of neoangiogenesis and proliferation. Hence the best scenario for the clinical use of venous flaps unfolds when both revascularization and skin coverage are required.« less
OUTCOMES OF HILAR PEDICLE CONTROL USING SUTURE LIGATION DURING LAPAROSCOPIC SPLENECTOMY.
Makgoka, M
2017-06-01
Laparoscopic splenectomy is a well described gold standard procedure for various indications. One of the key steps during laparoscopic splenectomy is the hilar pedicle vessels control, which can be challenging in most cases. Most centres around the world recommend the use Ligaclib or endovascular staplers as Methods of choice for hilar pedicle control but the issue is the cost and efficiency of the laparoscopic haemostatic devices. A descriptive retrospective study of patients who had laparoscopic splenectomy from 2013 to present. Hilar splenic vessel control was done with suture ligation. We looked at outcomes of patients offered this technique, complications of this technique, and describing the technique of hilar control in laparoscopic splenectomy. Total of 27 patients had laparoscopic splenectomy with splenic hilar pedicle control with suture ligation. Mean operative time, mean blood volume loss, length of hospital stay, postoperative complications conversion to laparotomy. Laparoscopic hilar pedicle control with suture ligation is safe and effective for the patient in our hospital setting.
Failure analysis of broken pedicle screws on spinal instrumentation.
Chen, Chen-Sheng; Chen, Wen-Jer; Cheng, Cheng-Kung; Jao, Shyh-Hua Eric; Chueh, Shan-Chang; Wang, Chang-Chih
2005-07-01
Revised spinal surgery is needed when there is a broken pedicle screw in the patient. This study investigated the pedicle screw breakage by conducting retrieval analyses of broken pedicle screws from 16 patients clinically and by performing stress analyses in the posterolateral fusion computationally using finite element (FE) models. Fracture surface of screws was studied by scanning electron microscope (SEM). The FE model of the posterolateral fusion with the screw showed that screws on the caudal side had larger axial stress than those on the cephalic side, supporting the clinical findings that 75% of the patients had the screw breakage on the caudal side. SEM fractography showed that all broken screws exhibited beach marks or striations on the fractured surface, indicating fatigue failure. Screws of patients with spinal fracture showed fatigue striations and final ductile fracture around the edge. Among the 16 patients who had broken pedicle screws 69% of them achieved bone union in the bone graft, showing that bone union in the bone graft did not warrant the prevention of screw breakage.
2014-01-01
Background: Breast reduction is well-known to provide an improvement in physical symptoms. However, measurements show that this procedure is less effective in restoring upper-pole fullness. Breast implants effectively augment the upper pole. This study was undertaken to determine the effectiveness and safety of this treatment combination. Methods: This retrospective study consists of 3 parts: (1) a clinical study, (2) breast measurements, and (3) an outcome study. Eighty consecutive women undergoing breast reduction (n = 56) or breast reduction plus implants (n = 24) were evaluated. All breast implants were inserted submuscularly. All patients were treated with the same vertical reduction technique, using a medially based pedicle and intraoperative nipple positioning. Measurements were compared between preoperative photographs and photographs taken at least 3 months after surgery (n = 51). Patient surveys (n= 56) were evaluated. Results: There was no significant difference in complication or reoperation rates between groups. Both procedures elevated the breast mound and lower-pole level and increased the breast parenchymal ratio (upper-pole area/lower-pole area). Breast implants significantly increased upper-pole projection (P < 0.01). All surveyed patients who had simultaneous implants reported that they were pleased with their decision. Physical symptoms were reduced in both groups. Patient satisfaction was 92.5% for breast reduction and 93.8% for breast reduction plus implants. Both groups reported an improvement in quality of life. Conclusions: Vertical breast reduction with a medial pedicle may be combined safely and effectively with breast implants in patients who desire upper-pole fullness. PMID:25587515
CLINICAL APPLICATION OF A DRILL GUIDE TEMPLATE FOR PEDICLE SCREW PLACEMENT IN SEVERE SCOLIOSIS.
Li, Xin; Zhang, Yaoshen; Zhang, Qiang; Zhao, Changsong; Liu, Kun
2017-01-01
To evaluate the accuracy and the effect of drill guide template for pedicle screw placement in severe scoliosis. Eight patients with rigid scoliosis were enrolled, five males and three females, ranging from nine to 23 years old. A three-dimensional CT scan of the spine was performed and saved as a DICOM file type. The multi-level template was designed by Mimics software and manufactured according to the part of the most severe deformity. The drill template was placed on the corresponding vertebral surface. Pedicle screws were carefully inserted across the trajectory of the template. Postoperatively, the positions of the pedicle screws were evaluated by CT scan and graded for validation. No spinal cord injury or nerve damage occurred. All patients had satisfactory outcomes. The abnormalities and the measures observed during operation were the same as those found in the preoperative period. The position of the pedicle screws was accurate, according to the postoperative X-ray and CT scan. The rate of scoliosis correction was 60%. Compared with controls, surgery time, blood loss and radiation were significantly lower. With the application of multi-level template, the placement of pedicle screws shows high accuracy in scoliosis with shorter surgical time, less blood loss and less radiation exposure. Level of Evidence III, Retrospective Comparative Study.
Pedicled Extranasal Flaps in Skull Base Reconstruction
Kim, Grace G.; Hang, Anna X.; Mitchell, Candace; Zanation, Adam M.
2013-01-01
Cerebrospinal fluid (CSF) leaks most commonly arise during or after skull base surgery, although they occasionally present spontaneously. Recent advances in the repair of CSF leaks have enabled endoscopic endonasal surgery to become the preferred option for management of skull base pathology. Small defects (<1cm) can be repaired by multilayered free grafts. For large defects (>3cm), pedicled vascular flaps are the repair method of choice, resulting in much lower rates of postoperative CSF leaks. The pedicled nasoseptal flap (NSF) constitutes the primary reconstructive option for the vast majority of skull base defects. It has a large area of potential coverage and high rates of success. However, preoperative planning is required to avoid sacrificing the NSF during resection. In cases where the NSF is unavailable, often due to tumor involvement of the septum or previous resection removing or compromising the flap, other flaps may be considered. These flaps include intranasal options—inferior turbinate (IT) or middle turbinate (MT) flaps—as well as regional pedicled flaps: pericranial flap (PCF), temporoparietal fascial flap (TPFF), or palatal flap (PF). More recently, novel alternatives such as the pedicled facial buccinator flap (FAB) and the pedicled occipital galeopericranial flap (OGP) have been added to the arsenal of options for skull base reconstruction. Characteristics of and appropriate uses for each flap are described. PMID:23257554
Cervical Fusion for Absent Pedicle Syndrome Manifesting with Myelopathy.
Goodwin, C Rory; Desai, Atman; Khattab, Mohamed H; Elder, Benjamin D; Bydon, Ali; Wolinsky, Jean-Paul
2016-02-01
Absent congenital pedicle syndrome is a posterior arch defect characterized by numerous congenital and mechanical abnormalities that result from disconnection of the anterior and posterior columns of the spinal canal. Absent congenital pedicle syndrome is a rare anomaly that is most commonly diagnosed incidentally, after evaluation of minor trauma, or after complaints of chronic neck pain. We report a case of absent congenital pedicle syndrome in a patient who presented with myelopathy and lower extremity weakness and review the literature on the surgical management of this entity. A 32-year-old woman with a history of systemic lupus erythematosus presented to the Neurosurgery Service with progressive weakness in her upper and lower extremities, clonus, and hyperreflexia. Magnetic resonance imaging revealed congenital absence of the pedicles of C2, C3, C4, C5, and C6 with a congenitally narrow canal at C4-5. The patient underwent a staged anterior and posterior cervical decompression and fusion. She was placed in a halo after surgery; at the 1-year follow-up, she was ambulatory with demonstrated improvement in weakness and fusion of her cervical spine. Absent congenital pedicle syndrome is rare, and most reported cases were treated conservatively. Surgical management is reserved for patients with myelopathy or instability. Copyright © 2016 Elsevier Inc. All rights reserved.
Pedicle screw placement using image guided techniques.
Merloz, P; Tonetti, J; Pittet, L; Coulomb, M; Lavalleé, S; Sautot, P
1998-09-01
Clinical evaluation of a computer assisted spine surgical system is presented. Eighty pedicle screws were inserted using computer assisted technology in thoracic and lumbar vertebrae for treatment of different types of disorders including fractures, spondylolisthesis, and scoliosis. Fifty-two patients with severe fractures, spondylolisthesis, or pseudoarthrosis of T10 to L5 were treated using a computer assisted technique on 1/2 the patients and performing the screw insertion manually for the other 1/2. At the same time, 28 pedicle screws were inserted in T12 to L4 vertebrae for scoliosis with the help of the computer assisted technique. Surgery was followed in all cases (66 vertebrae; 132 pedicle screws) by postoperative radiographs and computed tomographic examination, on which measurements of screw position relative to pedicle position could be done. For fractures, spondylolisthesis, or pseudarthrosis, comparison between the two groups showed that four screws in 52 (8%) vertebrae had incorrect placement with computer assisted technique whereas 22 screws in 52 (42%) vertebrae had incorrect placement with manual insertion. In patients with scoliosis, four screws in 28 (14%) vertebrae had incorrect placement. In all of the patients (132 pedicle screws) there were no neurologic complications. These results show that a computer assisted technique is much more accurate and safe than manual insertion.
Chiu, C K; Kwan, M K; Chan, C Y W; Schaefer, C; Hansen-Algenstaedt, N
2015-08-01
We undertook a retrospective study investigating the accuracy and safety of percutaneous pedicle screws placed under fluoroscopic guidance in the lumbosacral junction and lumbar spine. The CT scans of patients were chosen from two centres: European patients from University Medical Center Hamburg-Eppendorf, Germany, and Asian patients from the University of Malaya, Malaysia. Screw perforations were classified into grades 0, 1, 2 and 3. A total of 880 percutaneous pedicle screws from 203 patients were analysed: 614 screws from 144 European patients and 266 screws from 59 Asian patients. The mean age of the patients was 58.8 years (16 to 91) and there were 103 men and 100 women. The total rate of perforation was 9.9% (87 screws) with 7.4% grade 1, 2.0% grade 2 and 0.5% grade 3 perforations. The rate of perforation in Europeans was 10.4% and in Asians was 8.6%, with no significant difference between the two (p = 0.42). The rate of perforation was the highest in S1 (19.4%) followed by L5 (14.9%). The accuracy and safety of percutaneous pedicle screw placement are comparable to those cited in the literature for the open method of pedicle screw placement. Greater caution must be taken during the insertion of L5 and S1 percutaneous pedicle screws owing to their more angulated pedicles, the anatomical variations in their vertebral bodies and the morphology of the spinal canal at this location. ©2015 The British Editorial Society of Bone & Joint Surgery.
Ma, Xianjie; Li, Yang; Li, Weiyang; Liu, Chaohua; Peng, Pai; Song, Baoqiang; Xia, Wensen; Yi, Chenggang; Lu, Kaihua; Su, Yingjun
2017-09-01
The scars of face and scalp caused by burning often show as 1 large facial-scalp scar. The deltopectoral flap was recognized as one of the first choices for the facial scar reconstruction. However, this flap cannot cross the level of zygomatic arch traditionally when it was transferred with pedicle. When the flap reconstructed the facial-scalp scars with expanded random scalp flap, another flap was often needed to reconstruct the remaining temple and forehead scars. The authors reviewed 24 patients of large facial-scalp scars reconstructed by expanded pedicled deltopectoral flap and scalp flap with several technique improvements. The seaming scar between the deltopectoral flap and scalp flap in the temple region formed the new hairline. The technique improvements included ligation of the perforating branches of the transverse cervical artery and thoracoacromial artery when dissecting the pocket, the partial bolster compressive dressing to the distal part of the flap and dividing the pedicle partly as a delaying procedure before dividing the pedicle completely. Good skin compliance, normal contours, and emotional expression were noted. There were complications including expander exposure in 3 patients, stretch marks in 5 patients, flap tip necrosis in 2 patients, and mild postoperative hypertrophic scars in 3 patients. In conclusion, the expanded pedicled deltopectoral flap can enlarge the reconstructive territory in face successfully with the technique improvements. The combination of the expanded pedicled deltopectoral flap and scalp flap is a reliable and excellent reconstructive option for large postburn facial-scalp scars.
Pull out strength calculator for pedicle screws using a surrogate ensemble approach.
Varghese, Vicky; Ramu, Palaniappan; Krishnan, Venkatesh; Saravana Kumar, Gurunathan
2016-12-01
Pedicle screw instrumentation is widely used in the treatment of spinal disorders and deformities. Currently, the surgeon decides the holding power of instrumentation based on the perioperative feeling which is subjective in nature. The objective of the paper is to develop a surrogate model which will predict the pullout strength of pedicle screw based on density, insertion angle, insertion depth and reinsertion. A Taguchi's orthogonal array was used to design an experiment to find the factors effecting pullout strength of pedicle screw. The pullout studies were carried using polyaxial pedicle screw on rigid polyurethane foam block according to American society for testing of materials (ASTM F543). Analysis of variance (ANOVA) and Tukey's honestly significant difference multiple comparison tests were done to find factor effect. Based on the experimental results, surrogate models based on Krigging, polynomial response surface and radial basis function were developed for predicting the pullout strength for different combination of factors. An ensemble of these surrogates based on weighted average surrogate model was also evaluated for prediction. Density, insertion depth, insertion angle and reinsertion have a significant effect (p <0.05) on pullout strength of pedicle screw. Weighted average surrogate performed the best in predicting the pull out strength amongst the surrogate models considered in this study and acted as insurance against bad prediction. A predictive model for pullout strength of pedicle screw was developed using experimental values and surrogate models. This can be used in pre-surgical planning and decision support system for spine surgeon. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Kantelhardt, Sven R; Neulen, Axel; Keric, Naureen; Gutenberg, Angelika; Conrad, Jens; Giese, Alf
2017-10-01
Image-guided pedicle screw placement in the cervico-thoracic region is a commonly applied technique. In some patients with deformed cervico-thoracic segments, conventional or 3D fluoroscopy based registration of image-guidance might be difficult or impossible because of the anatomic/pathological conditions. Landmark based registration has been used as an alternative, mostly using separate registration of each vertebra. We here investigated a routine for landmark based registration of rigid spinal segments as single objects, using cranial image-guidance software. Landmark based registration of image-guidance was performed using cranial navigation software. After surgical exposure of the spinous processes, lamina and facet joints and fixation of a reference marker array, up to 26 predefined landmarks were acquired using a pointer. All pedicle screws were implanted using image guidance alone. Following image-guided screw placement all patients underwent postoperative CT scanning. Screw positions as well as intraoperative and clinical parameters were retrospectively analyzed. Thirteen patients received 73 pedicle screws at levels C6 to Th8. Registration of spinal segments, using the cranial image-guidance succeeded in all cases. Pedicle perforations were observed in 11.0%, severe perforations of >2 mm occurred in 5.4%. One patient developed a transient C8 syndrome and had to be revised for deviation of the C7 pedicle screw. No other pedicle screw-related complications were observed. In selected patients suffering from pathologies of the cervico-thoracic region, which impair intraoperative fluoroscopy or 3D C-arm imaging, landmark based registration of image-guidance using cranial software is a feasible, radiation-saving and a safe alternative.
Phonatory aerodynamics in connected speech.
Gartner-Schmidt, Jackie L; Hirai, Ryoji; Dastolfo, Christina; Rosen, Clark A; Yu, Lan; Gillespie, Amanda I
2015-12-01
1) Present phonatory aerodynamic data for healthy controls (HCs) in connected speech; 2) contrast these findings between HCs and patients with nontreated unilateral vocal fold paralysis (UVFP); 3) present pre- and post-vocal fold augmentation outcomes for patients with UVFP; 4) contrast data from patients with post-operative laryngeal augmentation to HCs. Retrospective, single-blinded. For phase I, 20 HC participants were recruited. For phase II, 20 patients with UVFP were age- and gender-matched to the 20 HC participants used in phase I. For phase III, 20 patients with UVFP represented a pre- and posttreatment cohort. For phase IV, 20 of the HC participants from phase I and 20 of the postoperative UVFP patients from phase III were used for direct comparison. Aerodynamic measures captured from a sample of the Rainbow Passage included: number of breaths, mean phonatory airflow rate, total duration of passage, inspiratory airflow duration, and expiratory airflow duration. The VHI-10 was also obtained pre- and postoperative laryngeal augmentation. All phonatory aerodynamic measures were significantly increased in patients with preoperative UVFP than the HC group. Patients with laryngeal augmentation took significantly less breaths, had less mean phonatory airflow rate during voicing, and had shorter inspiratory airflow duration than the preoperative UVFP group. None of the postoperative measures returned to HC values. Significant improvement in the Voice Handicap Index-10 scores postlaryngeal augmentation was also found. Methodology described in this study improves upon existing aerodynamic voice assessment by capturing characteristics germane to UVFP patient complaints and measuring change before and after laryngeal augmentation in connected speech. 4. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.
Adjacent-segment disease after thoracic pedicle screw fixation.
Agarwal, Nitin; Heary, Robert F; Agarwal, Prateek
2018-03-01
OBJECTIVE Pedicle screw fixation is a technique widely used to treat conditions ranging from spine deformity to fracture stabilization. Pedicle screws have been used traditionally in the lumbar spine; however, they are now being used with increasing frequency in the thoracic spine as a more favorable alternative to hooks, wires, or cables. Although safety concerns, such as the incidence of adjacent-segment disease (ASD) after cervical and lumbar fusions, have been reported, such issues in the thoracic spine have yet to be addressed thoroughly. Here, the authors review the literature on ASD after thoracic pedicle screw fixation and report their own experience specifically involving the use of pedicle screws in the thoracic spine. METHODS Select references from online databases, such as PubMed (provided by the US National Library of Medicine at the National Institutes of Health), were used to survey the literature concerning ASD after thoracic pedicle screw fixation. To include the authors' experience at Rutgers New Jersey Medical School, a retrospective review of a prospectively maintained database was performed to determine the incidence of complications over a 13-year period in 123 consecutive adult patients who underwent thoracic pedicle screw fixation. Children, pregnant or lactating women, and prisoners were excluded from the review. By comparing preoperative and postoperative radiographic images, the occurrence of thoracic ASD and disease within the surgical construct was determined. RESULTS Definitive radiographic fusion was detected in 115 (93.5%) patients. Seven incidences of instrumentation failure and 8 lucencies surrounding the screws were observed. One patient was observed to have ASD of the thoracic spine. The mean follow-up duration was 50 months. CONCLUSIONS This long-term radiographic evaluation revealed the use of pedicle screws for thoracic fixation to be an effective stabilization modality. In particular, ASD seems to be less of a problem in the relatively immobile thoracic spine than in the more mobile cervical and lumbar spines.
Kaneyama, Shuichi; Sugawara, Taku; Sumi, Masatoshi
2015-03-15
Clinical trial for midcervical pedicle screw insertion using a novel patient-specific intraoperative screw guiding device. To evaluate the availability of the "Screw Guide Template" (SGT) system for insertion of midcervical pedicle screws. Despite many efforts for accurate midcervical pedicle screw insertion, there still remain unacceptable rate of screw malpositioning that might cause neurovascular injuries. We developed patient-specific SGT system for safe and accurate intraoperative screw navigation tool and have reported its availability for the screw insertion to C2 vertebra and thoracic spine. Preoperatively, the bone image on computed tomography was analyzed and the trajectories of the screws were designed in 3-dimensional format. Three types of templates were created for each lamina: location template, drill guide template, and screw guide template. During the operations, after engaging the templates directly with the laminae, drilling, tapping, and screwing were performed with each template. We placed 80 midcervical pedicle screws for 20 patients. The accuracy and safety of the screw insertion by SGT system were evaluated using postoperative computed tomographic scan by calculation of screw deviation from the preplanned trajectory and evaluation of screw breach of pedicle wall. All templates fitted the laminae and screw navigation procedures proceeded uneventfully. All screws were inserted accurately with the mean screw deviation from planned trajectory of 0.29 ± 0.31 mm and no neurovascular complication was experienced. We demonstrated that our SGT system could support the precise screw insertion in midcervical pedicle. SGT prescribes the safe screw trajectory in a 3-dimensional manner and the templates fit and lock directly to the target laminae, which prevents screwing error along with the change of spinal alignment during the surgery. These advantages of the SGT system guarantee the high accuracy in screw insertion, which allowed surgeons to insert cervical pedicle screws safely. 3.
Blizzard, Daniel J; Thomas, J Alex
2018-03-15
Retrospective review of prospectively collected data of the first 72 consecutive patients treated with single-position one- or two-level lateral (LLIF) or oblique lateral interbody fusion (OLLIF) with bilateral percutaneous pedicle screw and rod fixation by a single spine surgeon. To evaluate the clinical feasibility, accuracy, and efficiency of a single-position technique for LLIF and OLLIF with bilateral pedicle screw and rod fixation. Minimally-invasive lateral interbody approaches are performed in the lateral decubitus position. Subsequent repositioning prone for bilateral pedicle screw and rod fixation requires significant time and resources and does not facilitate increased lumbar lordosis. The first 72 consecutive patients (300 screws) treated with single-position LLIF or OLLIF and bilateral pedicle screws by a single surgeon between December 2013 and August 2016 were included in the study. Screw accuracy and fusion were graded using computed tomography and several timing parameters were recorded including retractor, fluoroscopy, and screw placement time. Complications including reoperation, infection, and postoperative radicular pain and weakness were recorded. Average screw placement time was 5.9 min/screw (standard deviation, SD: 1.5 min; range: 3-9.5 min). Average total operative time (interbody cage and pedicle screw placement) was 87.9 minutes (SD: 25.1 min; range: 49-195 min). Average fluoroscopy time was 15.0 s/screw (SD: 4.7 s; range: 6-25 s). The pedicle screw breach rate was 5.1% with 10/13 breaches measured as < 2 mm in magnitude. Fusion rate at 6-months postoperative was 87.5%. Two (2.8%) patients underwent reoperation for malpositioned pedicle screws with subsequent resolution of symptoms. The single-position, all-lateral technique was found to be feasible with accuracy, fluoroscopy usage, and complication rates comparable with the published literature. This technique eliminates the time and staffing associated with intraoperative repositioning and may lead to significant improvements in operative efficiency and cost savings. 4.
Zuo, Chun-Guang; Liu, Xia-Jun; Wang, Xin-Hu; Wang, Jian-shun
2013-01-01
To discuss the therapeutic effects of the atlantoaxial pedicle screw system fixation in treatment of atlantoaxial instability. From June 2003 to March 2010, 32 patients with atlantoaxial instability were treated by atlantoaxial pedicle screw system fixation, included 21 males and 11 females wiht an average age of 42.5 years old ranging from 28 to 66 years. Among them, 18 cases were odontoid process fractures, 7 were congenital dissociate odontoid process, 4 were Jefferson fracture combined with odontoid fracture, 3 were rheumatic arthritis causing atlantoaxial instability. All patients suffered from the atlantoaxial subluxation and atlantoaxial instability. The JOA score ranged from 4 to 14 (means 9.1 +/- 0.3) before operation. The patients had some image examination including the X-ray of cervical vertebrae (include of dynamic position film), spiral CT 3D reconstruction and/or MRI. The position of pedicle screw system implantation,the angle of pedicle screw system implantation and screw length were measured. Operating skull traction. Operation undewent general anesthesia, implanted the pedicle screw, reduction and bone fusion under direct vision. The bone was fixated between posterior arch of atlas and lamina of axis by the lateral combination bended to posterior. One hundred and twenty-eight atlantoaxial pedicle screws were implanted in 32 patients. No patient had the injure of spinal cord, nerve root and vertebral artery. All patients were followed-up from 6 to 48 months (averaged 16 months). After operation, the JOA score ranged from 11 to 17 (averaged 15.9 +/- 0.2), improvement rate was 86.1%. The fracture of odontoid process were healing completely. All fusion bone were combinated. The internal fixation wasn't loosening and breaking. The atlantoaxial pedicle screw system fixation was effective method to treat atlantoaxial instability. The method had many advantages, such as provide rigid and short segment fixation, safe and simple, high fusion rate. The method was worth in clinical application.
Biomechanical evaluation of a new fixation device for the thoracic spine.
Hongo, Michio; Ilharreborde, Brice; Gay, Ralph E; Zhao, Chunfeng; Zhao, Kristin D; Berglund, Lawrence J; Zobitz, Mark; An, Kai-Nan
2009-08-01
The technology used in surgery for spinal deformity has progressed rapidly in recent years. Commonly used fixation techniques may include monofilament wires, sublaminar wires and cables, and pedicle screws. Unfortunately, neurological complications can occur with all of these, compromising the patients' health and quality of life. Recently, an alternative fixation technique using a metal clamp and polyester belt was developed to replace hooks and sublaminar wiring in scoliosis surgery. The goal of this study was to compare the pull-out strength of this new construct with sublaminar wiring, laminar hooks and pedicle screws. Forty thoracic vertebrae from five fresh frozen human thoracic spines (T5-12) were divided into five groups (8 per group), such that BMD values, pedicle diameter, and vertebral levels were equally distributed. They were then potted in polymethylmethacrylate and anchored with metal screws and polyethylene bands. One of five fixation methods was applied to the right side of the vertebra in each group: Pedicle screw, sublaminar belt with clamp, figure-8 belt with clamp, sublaminar wire, or laminar hook. Pull-out strength was then assessed using a custom jig in a servohydraulic tester. The mean failure load of the pedicle screw group was significantly larger than that of the figure-8 clamp (P = 0.001), sublaminar belt (0.0172), and sublaminar wire groups (P = 0.04) with no significant difference in pull-out strength between the latter three constructs. The most common mode of failure was the fracture of the pedicle. BMD was significantly correlated with failure load only in the figure-8 clamp and pedicle screw constructs. Only the pedicle screw had a statistically significant higher failure load than the sublaminar clamp. The sublaminar method of applying the belt and clamp device was superior to the figure-8 method. The sublaminar belt and clamp construct compared favorably to the traditional methods of sublaminar wires and laminar hooks, and should be considered as an alternative fixation device in the thoracic spine.
Biomechanical evaluation of a new fixation device for the thoracic spine
Hongo, Michio; Ilharreborde, Brice; Zhao, Chunfeng; Zhao, Kristin D.; Berglund, Lawrence J.; Zobitz, Mark; An, Kai-Nan
2009-01-01
The technology used in surgery for spinal deformity has progressed rapidly in recent years. Commonly used fixation techniques may include monofilament wires, sublaminar wires and cables, and pedicle screws. Unfortunately, neurological complications can occur with all of these, compromising the patients’ health and quality of life. Recently, an alternative fixation technique using a metal clamp and polyester belt was developed to replace hooks and sublaminar wiring in scoliosis surgery. The goal of this study was to compare the pull-out strength of this new construct with sublaminar wiring, laminar hooks and pedicle screws. Forty thoracic vertebrae from five fresh frozen human thoracic spines (T5–12) were divided into five groups (8 per group), such that BMD values, pedicle diameter, and vertebral levels were equally distributed. They were then potted in polymethylmethacrylate and anchored with metal screws and polyethylene bands. One of five fixation methods was applied to the right side of the vertebra in each group: Pedicle screw, sublaminar belt with clamp, figure-8 belt with clamp, sublaminar wire, or laminar hook. Pull-out strength was then assessed using a custom jig in a servohydraulic tester. The mean failure load of the pedicle screw group was significantly larger than that of the figure-8 clamp (P = 0.001), sublaminar belt (0.0172), and sublaminar wire groups (P = 0.04) with no significant difference in pull-out strength between the latter three constructs. The most common mode of failure was the fracture of the pedicle. BMD was significantly correlated with failure load only in the figure-8 clamp and pedicle screw constructs. Only the pedicle screw had a statistically significant higher failure load than the sublaminar clamp. The sublaminar method of applying the belt and clamp device was superior to the figure-8 method. The sublaminar belt and clamp construct compared favorably to the traditional methods of sublaminar wires and laminar hooks, and should be considered as an alternative fixation device in the thoracic spine. PMID:19404687
[APPLICATION VALUE OF INDOCYANINE GREEN ANGIOGRAPHY IN FLAP RECONSTRUCTIVE SURGERY].
Yang, Kai; Mu, Lan; Liu, Yan; Peng, Zhe; Li, Guangxue
2015-09-01
To investigate the utility of indocyanine green angiography in flap reconstructive surgery and possibility of decrease the complications. Indocyanine green angiography was performed on 14 patients undergoing flap reconstructive surgery between February and December 2014 to evaluate the blood perfusion of the flap and to adjust the operation plan. Of 14 cases, 2 were male and 12 were female, aged 23-58 years (mean, 35.5 years); 11 flaps were used for breast reconstruction [including 3 free deep inferior epigastric antery perforator (DIEP) flaps, 4 pedicled transverse rectus abdominis myocutaneous flaps (TRAM), 2 pedicled TRAM and free TRAM, and 2 pedicled latissimus dorsi myocutaneous flaps and prosthesis], 1 pedicled latissimus dorsi myocutaneous flap for repairing chest wall defect, 1 pedicled profunda artery perforator (PAP) flap for upper leg defect, and 1 pedicled descending genicular artery perforator flap for knee defect. The size of the flaps ranged from 9 cm x 6 cm to 26 cm x 12 cm. A total of 32 indocyanine green angiography were performed. There was no adverse reactions to the infusion of indocyanine green. The surgery management was adjusted according to results of indocyanine green angiography findings in 5 of 14 cases. The distal part of flap were discarded because of poor perfusion in 3 cases (1 DIEP flap, 1 TRAM, and 1 PAP flap) and the other 2 cases (pedicled TRAM) needed additional free anastomosis to ensure sufficient blood supply (pedicled TRAM and free TRAM); the other flaps were harvested according to preoperative plan and repaired defect successfully. The mean follow-up was 5 months (range, 1-9 months). The other flaps survived without infection or fat necrosis except 1 PAP flap with distal necrosis. Intraoperative indocyanine green angiography can provide real-time information of flap perfusion and then the operation plan can be adjusted in time to ensure the flap survival.
Oba, Hiroki; Ebata, Shigeto; Takahashi, Jun; Koyama, Kensuke; Uehara, Masashi; Kato, Hiroyuki; Haro, Hirotaka; Ohba, Tetsuro
2018-06-11
Observational cohort study. To compare the rate of pedicle perforation while inserting screws (PS) using O-arm navigation during surgery for scoliosis with that reported previously, and to determine risk factors specific to O-arm navigation. O-arm navigation provides intraoperative three-dimensional fluoroscopic imaging with an image quality similar to that of computed tomography. Surgeons have started using O-arm navigation in treatment of adolescent idiopathic sclerosis (AIS). However, there are few reports of the perforation rate when using O-arm navigation to insert pedicle screws for AIS. To our knowledge, no information has been published regarding risk factors for pedicle perforation by PS when using O-arm navigation during surgery for AIS. We retrospectively reviewed the cases of 23 consecutive patients with AIS (all female; mean age 15.4 years, range 12-19 years) who had all undergone PS fixation under O-arm navigation. There were 11 major pedicle perforations (Grade 2 or 3) by the 404 screws (2.7%). For both Grade 1-3 and Grade 2 or 3 perforations, the pedicle perforation rate by the ninth or subsequent screws was significantly higher than that for the other two groups (screws 1-4, 5-8) (P < 0.01). Grade 1-3, Grades 2 or 3, and Grade 3 perforation rates after a previous perforation were significantly higher than those in patients without a previous perforation (P < 0.01). The rate of screw deviation can increase significantly to 12.2% after insertion of 8. The rate of major perforation of pedicles after inserting PS using O-arm navigation during surgery for AIS is relatively low. However, we recommend caution using intraoperative navigation after inserting 8 pedicle screws because after this, the trajectory deviation rate can increase significantly. 3.
Kotani, Yoshihisa; Abumi, Kuniyoshi; Ito, Manabu; Takahata, Masahiko; Sudo, Hideki; Ohshima, Shigeki; Minami, Akio
2007-06-15
The accuracy of pedicle screw placement was evaluated in posterior scoliosis surgeries with or without the use of computer-assisted surgical techniques. In this retrospective cohort study, the pedicle screw placement accuracy in posterior scoliosis surgery was compared between conventional fluoroscopic and computer-assisted surgical techniques. There has been no study systemically analyzing the perforation pattern and comparative accuracy of pedicle screw placement in posterior scoliosis surgery. The 45 patients who received posterior correction surgeries were divided into 2 groups: Group C, manual control (25 patients); and Group N, navigation surgery (20 patients). The average Cobb angles were 73.7 degrees and 73.1 degrees before surgery in Group C and Group N, respectively. Using CT images, vertebral rotation, pedicle axes as measured to anteroposterior sacral axis and vertebral axis, and insertion angle error were measured. In perforation cases, the angular tendency, insertion point, and length abnormality were evaluated. The perforation was observed in 11% of Group C and 1.8% in Group N. In Group C, medial perforations of left screws were demonstrated in 8 of 9 perforated screws and 55% were distributed either in L1 or T12. The perforation consistently occurred in pedicles in which those axes approached anteroposterior sacral axis within 5 degrees . The average insertion errors were 8.4 degrees and 5.0 degrees in Group C and Group N, respectively, which were significantly different (P < 0.02). The medial perforation in Group C occurred around L1, especially when pedicle axis approached anteroposterior sacral axis. This consistent tendency was considered as the limitation of fluoroscopic screw insertion in which horizontal vertebral image was not visible. The use of surgical navigation system successfully reduced the perforation rate and insertion angle errors, demonstrating the clear advantage in safe and accurate pedicle screw placement of scoliosis surgery.
Latissimus Dorsi Flap in Breast Reconstruction
Sood, Rachita; Easow, Jeena M.; Konopka, Geoffrey; Panthaki, Zubin J.
2018-01-01
Background: Surgeons employ the latissimus dorsi flap (LDF) for reconstruction of a large variety of breast cancer surgery defects, including quadrantectomy, lumpectomy, modified radical mastectomy, and others. The LDF may be used in delayed or immediate reconstruction, in combination with tissue expanders for a staged reconstruction, with implant-based immediate reconstruction, or alone as an autogenous flap. Methods: The authors discuss the historical uses and more recent developments in the LDF. More recent advancements, including the “scarless” approach and augmentation with the thoracodorsal artery perforator flap, are discussed. Results: The LDF is a reliable means for soft tissue coverage providing form and function during breast reconstruction with acceptable perioperative and long-term morbidities. Conclusions: When there is a paucity of tissue, the LDF can provide tissue volume in autologous reconstruction, as well as a reliable vascular pedicle for implant-based reconstruction as in the setting of irradiated tissue. PMID:29334788
Palacio, M M; Van Aalst, V C; Perez Abadia, G A; Stremel, R W; Werker, P M; Ren, X; Petty, G D; Heilman, S J; Van Savage, J G; Garcia Fernandez, A; Kon, M; Tobin, G R; Barker, J H
1998-11-01
To reconstruct an electrically stimulated muscular urinary sphincter (MUS) using a tailored gracilis muscle free flap with intact nerve. Unilateral surgically tailored gracilis muscle free flaps were transferred into the pelvis in eight dogs, leaving the obturator nerve intact. The muscle's pedicle vessels were anastomosed to the inferior epigastric artery and vein in the pelvis and the muscle was wrapped around the bladder neck. Electrodes were inserted into the MUS and connected to a programmable pulse generator. After 8 weeks of training the MUS, the pulse generator was programmed to be "on" for 4 hours and "off' for 15 minutes in a continuous cycle. Urodynamic studies were performed periodically, and at the end of the experiment the MUS and proximal urethra were harvested for histology. Three control dogs had sham operations. All MUS's functioned well following the procedure. Histology of the MUS/urethra complex showed no evidence of stricture. Except for one dog, all urethras were easily catheterized. This electrically stimulated innervated free-flap MUS technique effectively increases bladder outlet resistance without producing urethral obstruction.
Zijderveld, Steven A; Zerbo, Ilara R; van den Bergh, Johan P A; Schulten, Engelbert A J M; ten Bruggenkate, Chris M
2005-01-01
A prospective human clinical study was conducted to determine the clinical and histologic bone formation ability of 2 graft materials, a beta-tricalcium phosphate (Cerasorb; Curasan, Kleinostheim, Germany) and autogenous chin bone, in maxillary sinus floor elevation surgery. Ten healthy patients underwent a bilateral (n = 6) or unilateral (n = 4) maxillary sinus floor elevation procedure under local anesthesia. In each case, residual posterior maxillary bone height was between 4 and 8 mm. In cases of bilateral sinus floor elevation, the original bone was augmented with a split-mouth design with 100% beta-tricalcium phosphate on the test side and 100% chin bone on the contralateral control side. The unilateral cases were augmented with 100% beta-tricalcium phosphate. After a healing period of 6 months, ITI full body screw-type implants (Straumann, Waldenburg, Switzerland) were placed. At the time of implant surgery, biopsy samples were removed with a 3.5-mm trephine drill. Sixteen sinus floor elevations were performed. Forty-one implants were placed, 26 on the test side and 15 on the control side. The clinical characteristics at the time of implantation differed, especially regarding clinical appearance and drilling resistance. The increase in height was examined radiographically prior to implantation and was found to be sufficient in all cases. After a mean of nearly 1 year of follow-up, no implant losses or failures had occurred. The promising clinical results of the present study and the lack of implant failures are probably mainly the result of requiring an original bone height of at least 4 mm at the implant location. Although autogenous bone grafting is still the gold standard, according to the clinical results, the preimplantation sinus floor elevation procedure used, which involved a limited volume of beta-tricalcium phosphate, appeared to be a clinically reliable procedure in this patient population.
Biomechanics of an Expandable Lumbar Interbody Fusion Cage Deployed Through Transforaminal Approach
Mica, Michael Conti; Voronov, Leonard I.; Carandang, Gerard; Havey, Robert M.; Wojewnik, Bartosz
2017-01-01
Introduction A novel expandable lumbar interbody fusion cage has been developed which allows for a broad endplate footprint similar to an anterior lumbar interbody fusion (ALIF); however, it is deployed from a minimally invasive transforaminal unilateral approach. The perceived benefit is a stable circumferential fusion from a single approach that maintains the anterior tension band of the anterior longitudinal ligament. The purpose of this biomechanics laboratory study was to evaluate the biomechanical stability of an expandable lumbar interbody cage inserted using a transforaminal approach and deployed in situ compared to a traditional lumbar interbody cage inserted using an anterior approach (control device). Methods Twelve cadaveric spine specimens (L1-L5) were tested intact and after implantation of both the control and experimental devices in two (L2-L3 and L3-L4) segments of each specimen; the assignments of the control and experimental devices to these segments were alternated. Effect of supplemental pedicle screw-rod stabilization was also assessed. Moments were applied to the specimens in flexion-extension (FE), lateral bending (LB), and axial rotation (AR). The effect of physiologic preload on construct stability was evaluated in FE. Segmental motions were measured using an optoelectronic motion measurement system. Results The deployable expendable TLIF cage and control devices significantly reduced FE motion with and without compressive preload when compared to the intact condition (p<0.05). Segmental motions in LB and AR were also significantly reduced with both devices (p<0.05). Under no preload, the deployable expendable TLIF cage construct resulted in significantly smaller FE motion compared to the control cage construct (p<0.01). Under all other testing modes (FE under 400N preload, LB, and AR) the postoperative motions of the two constructs did not differ statistically (p>0.05). Adding bilateral pedicle screws resulted in further reduction of ROM for all loading modes compared to intact condition, with no statistical difference between the two constructs (p>0.05). Conclusions The ability of the deployable expendable interbody cage in reducing segmental motions was equivalent to the control cage when used as a stand-alone construct and also when supplemented with bilateral pedicle screw-rod instrumentation. The larger footprint of the fully deployed TLIF cage combined with preservation of the anterior soft-tissue tension band may provide a better biomechanical fusion environment by combining the advantages of the traditional ALIF and TLIF approaches. PMID:29372129
Malham, Gregory M; Parker, Rhiannon M
2018-04-01
OBJECTIVE Image guidance for spine surgery has been reported to improve the accuracy of pedicle screw placement and reduce revision rates and radiation exposure. Current navigation and robot-assisted techniques for percutaneous screws rely on bone-anchored trackers and Kirchner wires (K-wires). There is a paucity of published data regarding the placement of image-guided percutaneous screws without K-wires. A new skin-adhesive stereotactic patient tracker (SpineMask) eliminates both an invasive bone-anchored tracker and K-wires for pedicle screw placement. This study reports the authors' early experience with the use of SpineMask for "K-wireless" placement of minimally invasive pedicle screws and makes recommendations for its potential applications in lumbar fusion. METHODS Forty-five consecutive patients (involving 204 screws inserted) underwent K-wireless lumbar pedicle screw fixation with SpineMask and intraoperative neuromonitoring. Screws were inserted by percutaneous stab or Wiltse incisions. If required, decompression with or without interbody fusion was performed using mini-open midline incisions. Multimodality intraoperative neuromonitoring assessing motor and sensory responses with triggered electromyography (tEMG) was performed. Computed tomography scans were obtained 2 days postoperatively to assess screw placement and any cortical breaches. A breach was defined as any violation of a pedicle screw involving the cortical bone of the pedicle. RESULTS Fourteen screws (7%) required intraoperative revision. Screws were removed and repositioned due to a tEMG response < 13 mA, tactile feedback, and 3D fluoroscopic assessment. All screws were revised using the SpineMask with the same screw placement technique. The highest proportion of revisions occurred with Wiltse incisions (4/12, 33%) as this caused the greatest degree of SpineMask deformation, followed by a mini midline incision (3/26, 12%). Percutaneous screws via a single stab incision resulted in the fewest revisions (7/166, 4%). Postoperative CT demonstrated 7 pedicle screw breaches (3%; 5 lateral, 1 medial, 1 superior), all with percutaneous stab incisions (7/166, 4%). The radiological accuracy of the SpineMask tracker was 97% (197/204 screws). No patients suffered neural injury or required postoperative screw revision. CONCLUSIONS The noninvasive cutaneous SpineMask tracker with 3D image guidance and tEMG monitoring provided high accuracy (97%) for percutaneous pedicle screw placement via stab incisions without K-wires.
Hou, Yang; Lin, Yanping; Shi, Jiangang; Chen, Huajiang; Yuan, Wen
2018-03-14
The virtual simulation surgery has initially exhibited its promising potentials in neurosurgery training. To evaluate effectiveness of the Virtual Surgical Training System (VSTS) on novice residents placing thoracic pedicle screws in a cadaver study. A total of 10 inexperienced residents participated in this study and were randomly assigned to 2 groups. The group using VSTS to learn thoracic pedicle screw fixation was the simulation training (ST) group and the group receiving an introductory teaching session was the control group. Ten fresh adult spine specimens including 6 males and 4 females with a mean age of 58.5 yr (range: 33-72) were collected and randomly allocated to the 2 groups. After exposing anatomic structures of thoracic spine, the bilateral pedicle screw placement of T6-T12 was performed on each cadaver specimen. The postoperative computed tomography scan was performed on each spine specimen, and experienced observers independently reviewed the placement of the pedicle screws to assess the incidence of pedicle breach. The screw penetration rates of the ST group (7.14%) was significantly lower in comparison to the control group (30%, P < .05). Statistically significant difference in acceptable rates of screws also occurred between the ST (100%) and control (92.86%) group (P < .05). In addition, the average screw penetration distance in control group (2.37 mm ± 0.23 mm) was significantly greater than ST group (1.23 mm ± 0.56 mm, P < .05). The virtual reality surgical training of thoracic pedicle screw instrumentation effectively improves surgical performance of novice residents compared to those with traditional teaching method, and can help new beginners to master the surgical technique within shortest period of time.
Schizas, Constantin; Theumann, Nicolas; Kosmopoulos, Victor
2007-05-01
Several studies have looked at accuracy of thoracic pedicle screw placement using fluoroscopy, image guidance, and anatomical landmarks. To our knowledge the upper thoracic spine (T1-T6) has not been specifically studied in the context of screw insertion and placement accuracy without the use of either image guidance or fluoroscopy. Our objective was to study the accuracy of upper thoracic screw placement without the use of fluoroscopy or image guidance, and report on implant related complications. A single surgeon inserted 60 screws in 13 consecutive non-scoliotic spine patients. These were the first 60 screws placed in the high thoracic spine in our institution. The most common diagnosis in our patient population was trauma. All screws were inserted using a modified Roy-Camille technique. Post-operative axial computed tomography (CT) images were obtained for each patient and analyzed by an independent senior radiologist for placement accuracy. Implant related complications were prospectively noted. No pedicle screw misplacement was found in 61.5% of the patients. In the remaining 38.5% of patients some misplacements were noted. Fifty-three screws out of the total 60 implanted were placed correctly within all the pedicle margins. The overall pedicle screw placement accuracy was 88.3% using our modified Roy-Camille technique. Five medial and two lateral violations were noted in the seven misplaced screws. One of the seven misplaced screws was considered to be questionable in terms of pedicle perforation. No implant related complications were noted. We found that inserting pedicle screws in the upper thoracic spine based solely on anatomical landmarks was safe with an accuracy comparable to that of published studies using image-guided navigation at the thoracic level.
Chiu, Chee Kidd; Chan, Chris Yin Wei; Kwan, Mun Keong
2017-01-01
This study investigates the safety and accuracy of percutaneous pedicle screws placed using fluoroscopic guidance in the thoracolumbosacral spine among Asian patients. Computerized tomography scans of 128 patients who had surgery using fluoroscopic-guided percutaneous pedicle screws were selected. Medial, lateral, superior, and inferior screw perforations were classified into grade 0 (no violation), grade 1 (<2 mm perforation), grade 2 (2-4 mm perforation), and grade 3(>4 mm perforation). Anterior perforations were classified into grade 0 (no violation), grade 1 (<4 mm perforation), grade 2 (4-6 mm perforation), and grade 3(>6 mm perforation). Grade 2 and grade 3 perforation were considered as "critical" perforation. In total, 1002 percutaneous pedicle screws from 128 patients were analyzed. The mean age was 52.7 ± 16.6. There were 70 male patients and 58 female patients. The total perforation rate was 11.3% (113) with 8.4% (84) grade 1, 2.6% (26) grade 2, and 0.3% (3) grade 3 perforations. The overall "critical" perforation rate was 2.9% (29 screws) and no complications were noted. The highest perforation rates were at T4 (21.6%), T2 (19.4%), and T6 (19.2%). The total perforation rate of 11.3% with the total "critical" perforation rate of 2.9% (2.6% grade 2 and 0.3% grade 3 perforations). The highest perforation rates were found over the upper to mid-thoracic region. Fluoroscopic-guided percutaneous pedicle screws insertion among Asians has the safety and accuracy comparable to the current reported percutaneous pedicle screws and open pedicle screws techniques.
Bekara, Farid; Herlin, Christian; Mojallal, Ali; Sinna, Raphael; Ayestaray, Benoit; Letois, Flavie; Chavoin, Jean Pierre; Garrido, Ignacio; Grolleau, Jean Louis; Chaput, Benoit
2016-01-01
Currently, increased interest in the perforator-pedicled propeller flap should not obscure the fact that it is, in reality, a complex procedure requiring experience and monitoring similar to free flaps. Through a meta-analysis, the authors aimed to identify the risk factors of perforator-pedicled propeller flap failure in lower extremity defects. The MEDLINE, PubMed Central, Embase, and Cochrane databases were searched from 1991 to May of 2014 for articles describing perforator-pedicled propeller flaps in the lower extremity. The study selection met the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. Fixed-effects models were used. Forty articles complied with the inclusion criteria, representing 428 perforator-pedicled propeller flaps. The most common cause was posttraumatic (55.2 percent). Most of the defects were at the distal third of the lower leg (45.6 percent). The arc of rotation was 180 degrees for 34.3 percent. Complications were found in 25.2 percent, including partial necrosis (10.2 percent) and complete necrosis (3.5 percent). Complete flap survival was found in 84.3 percent. The authors identified three significant risk factors: age older than 60 years (relative risk, 1.61; p = 0.03), diabetes (relative risk, 2.00; p = 0.02), and arteriopathy (relative risk, 3.12; p = 0.01). No significant results were found regarding smoking status other than a tendency (p = 0.06), acute cause (p = 0.59), posttraumatic cause (p = 0.97), distal third of the lower leg (p = 0.66), fascia inclusion (p = 0.70), and pedicle rotation greater than 120 degrees (p = 0.41). Age older than 60 years, diabetes, and arteriopathy are significant risk factors of perforator-pedicled propeller flap complications in the lower extremity. Risk, IV.
Fomekong, Edward; Pierrard, Julien; Raftopoulos, Christian
2018-03-01
The major limitation of computer-based three-dimensional fluoroscopy is increased radiation exposure of patients and operating room staff. Combining spine navigation with intraoperative three-dimensional fluoroscopy (io3DF) can likely overcome this shortcoming, while increasing pedicle screw accuracy rate. We compared data from a cohort of patients undergoing lumbar percutaneous pedicle screw placement using io3DF alone or in combination with spine navigation. This study consisted of 168 patients who underwent percutaneous pedicle screw implantation between 2009 and 2016. The primary endpoint was to compare pedicle screw accuracy between the 2 groups. Secondary endpoints were to compare radiation exposure of patients and operating room staff, duration of surgery, and postoperative complications. In group 1, 438 screws were placed without navigation guidance; in group 2, 276 screws were placed with spine navigation. Mean patient age in both groups was 58.6 ± 14.1 years. The final pedicle accuracy rate was 97.9% in group 1 and 99.6% in group 2. Average radiation dose per patient was significantly larger in group 1 (571.9 mGym 2 ) than in group 2 (365.6 mGym 2 ) (P = 0.000088). Surgery duration and complication rate were not significantly different between the 2 groups (P > 0.05). io3DF with spine navigation minimized radiation exposure of patients and operating room staff and provided an excellent percutaneous pedicle screw accuracy rate with no permanent complications compared with io3DF alone. This setup is recommended, especially for patients with a complex degenerative spine condition. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Bakhous, Christine; Aubert, Benjamin; Vazquez, Carlos; Cresson, Thierry; Parent, Stefan; De Guise, Jacques
2018-02-01
The 3D analysis of the spine deformities (scoliosis) has a high potential in its clinical diagnosis and treatment. In a biplanar radiographs context, a 3D analysis requires a 3D reconstruction from a pair of 2D X-rays. Whether being fully-/semiautomatic or manual, this task is complex because of the noise, the structure superimposition and partial information due to a limited projections number. Being involved in the axial vertebra rotation (AVR), which is a fundamental clinical parameter for scoliosis diagnosis, pedicles are important landmarks for the 3D spine modeling and pre-operative planning. In this paper, we focus on the extension of a fully-automatic 3D spine reconstruction method where the Vertebral Body Centers (VBCs) are automatically detected using Convolutional Neural Network (CNN) and then regularized using a Statistical Shape Model (SSM) framework. In this global process, pedicles are inferred statistically during the SSM regularization. Our contribution is to add a CNN-based regression model for pedicle detection allowing a better pedicle localization and improving the clinical parameters estimation (e.g. AVR, Cobb angle). Having 476 datasets including healthy patients and Adolescent Idiopathic Scoliosis (AIS) cases with different scoliosis grades (Cobb angles up to 116°), we used 380 for training, 48 for testing and 48 for validation. Adding the local CNN-based pedicle detection decreases the mean absolute error of the AVR by 10%. The 3D mean Euclidian distance error between detected pedicles and ground truth decreases by 17% and the maximum error by 19%. Moreover, a general improvement is observed in the 3D spine reconstruction and reflected in lower errors on the Cobb angle estimation.
Kato, Fumihiko; Ito, Keigo; Nakashima, Hiroaki; Machino, Masaaki
2009-01-01
Anterior procedures in the cervical spine are feasible in cases having anterior aetiologies such as anterior neural compression and/or severe kyphosis. Halo vests or anterior plates are used concurrently for cases with long segmental fixation. Halo vests are bothersome and anterior plate fixation is not adequately durable. We developed a new anterior pedicle screw (APS) and plate fixation procedure that can be used with fluoroscope-assisted pedicle axis view imaging. Six patients (3 men and 3 women; mean age, 54 years) with anterior multisegmental aetiology were included in this study. Their original diagnoses comprised cervical myelopathy and/or radiculopathy (n = 4), posterior longitudinal ligament ossification (n = 1) and post-traumatic kyphosis (n = 1). All patients underwent anterior decompression and strut grafting with APS and plate fixation. Mean operative time was 192 min and average blood loss was 73 ml. Patients were permitted to ambulate the next day with a cervical collar. Local sagittal alignment was characterised by 3.5° of kyphosis preoperatively, which improved to 6.8° of lordosis postoperatively and 5.2° of lordosis at final follow-up. Postoperative improvement and early bony union were observed in all cases. There was no serious complication except for two cases of dysphagia. Postoperative imaging demonstrated screw exposure in one screw, but no pedicle perforation. APS and plate fixation is useful in selected cases of multisegmental anterior reconstruction of cervical spine. However, the adequate familiarity and experience with both cervical pedicle screw fixation and the imaging technique used for visualising the pedicle during surgery are crucial for this procedure. PMID:19343377
Defining the Role of Free Flaps in Partial Breast Reconstruction.
Smith, Mark L; Molina, Bianca J; Dayan, Erez; Jablonka, Eric M; Okwali, Michelle; Kim, Julie N; Dayan, Joseph H
2018-03-01
Free flaps have a well-established role in breast reconstruction after mastectomy; however, their role in partial breast reconstruction remains poorly defined. We reviewed our experience with partial breast reconstruction to better understand indications for free tissue transfer. A retrospective review was performed of all patients undergoing partial breast reconstruction at our center between February 2009 and October 2015. We evaluated the characteristics of patients who underwent volume displacement procedures versus volume replacement procedures and free versus pedicled flap reconstruction. There were 78 partial breast reconstructions, with 52 reductions/tissue rearrangements (displacement group) and 26 flaps (replacement group). Bra cup size and body mass index (BMI) were significantly smaller in the replacement group. Fifteen pedicled and 11 free flaps were performed. Most pedicled flaps (80.0%) were used for lateral or upper pole defects. Most free flaps (72.7%) were used for medial and inferior defects or when there was inadequate donor tissue for a pedicled flap. Complications included hematoma, cellulitis, and one aborted pedicled flap. Free and pedicled flaps are useful for partial breast reconstruction, particularly in breast cancer patients with small breasts undergoing breast-conserving treatment (BCT). Flap selection depends on defect size, location, and donor tissue availability. Medial defects are difficult to reconstruct using pedicled flaps due to arc of rotation and intervening breast tissue. Free tissue transfer can overcome these obstacles. Confirming negative margins before flap reconstruction ensures harvest of adequate volume and avoids later re-operation. Judicious use of free flaps for oncoplastic reconstruction expands the possibility for breast conservation. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Osseous anatomy of the lumbosacral spine in Marfan syndrome.
Sponseller, P D; Ahn, N U; Ahn, U M; Nallamshetty, L; Rose, P S; Kuszyk, B S; Fishman, E K
2000-11-01
This study examines pedicle widths, laminar thicknesses, and scalloping values for lumbosacral spine elements in Marfan volunteers. Comparisons were made between these measurements and norms as well as measurements between Marfan patients with and without dural ectasia. To determine if the lumbosacral vertebral elements are altered in the patient with Marfan syndrome. Several abnormalities have been noted in Marfan lumbar spine, including pedicular attenuation and widened interpediculate distances. This may be due to abnormalities of growth or presence of dural ectasia. Given the large numbers of Marfan patients requiring spinal surgery and the high postoperative failure rate, better understanding of the bony anatomy of Marfan lumbar spine is necessary, especially if use of instrumentation is anticipated. Thirty-two volunteers with Marfan syndrome based on the Ghent criteria underwent spiral computed tomography of the lumbosacral spine. Images were evaluated for dural ectasia, and measurements of pedicle width, laminar thickness, and vertebral scalloping were made. Pedicle widths and laminar thicknesses were significantly smaller in Marfan patients at all levels (P<0.001). Mean pedicle widths at L1-L3 were smaller than the smallest available pedicle screw (5 mm). In Marfan patients with dural ectasia, laminar thickness from L5-S2 and pedicle widths at all lumbar levels were significantly reduced (P<0.01). Vertebral scalloping at S1 was significantly greater in Marfan patients with dural ectasia (P = 0.02). Lumbar pedicle width and laminar thickness are significantly reduced in Marfan individuals. Those with dural ectasia demonstrate increased bony erosion of anterior and posterior elements of lumbosacral spine. Preoperative planning and routine computed tomography scans are recommended when operating on Marfan lumbosacral spine.
Effect of fibrin sealant in positioning and stabilizing microvascular pedicle: A comparative study.
Kim, Jeong Tae; Kim, Youn Hwan; Kim, Sang Wha
2017-07-01
Fibrin sealants have had applications in hemostasis, cohesion, and promotion of healing in plastic surgery. In this article, we review cases where fibrin sealant was used to stabilize microvascular pedicles and compared with previous free flaps performed without fibrin sealant. Between 2008 and 2010, 62 consecutive patients underwent free tissue transfer for reconstruction; this involved 33 latissimus dorsi perforator flaps, 14 thoracodorsal artery perforator flaps, 9 latissimus dorsi myocutaneous flaps, 3 lateral thoracic artery perforator flaps, and 3 transverse rectus abdominis myocutaneous flaps, used in head and neck reconstruction, lower limb reconstructions, breast reconstructions, and facial palsy reconstruction. Following microvascular anastomosis, the microvascular pedicles were placed in the optimal position, and fibrin sealant was used to fix and stabilize them. The complications, such as venous thrombosis, arterial thrombosis, hematoma, and vascular pedicle kinking, were compared with that of 672 previous free flaps without fibrin sealant for stabilizing microvascular pedicles. Among the 62 free tissue transfers using fibrin sealant, there was only one complication involving flap failure (1.6%), in this case due to venous thrombosis. Analysis of 672 free flaps performed without application of fibrin sealant revealed 24 complications (3.6%), due to 3 venous thrombosis, 1 arterial thrombosis, 4 vascular pedicel compression due to hematoma, and 16 pedicle kinking. However, the comparison of complications between the free flap using fibrin sealant and the free flap without fibrin sealant were not statistically significant (P = 0.65). Fibrin sealant can be used to prevent vascular kinking and to position anastomosed vessels after successful micro-anastomosis and allow the reconstructive surgeon to overcome challenging situations of vascular pedicle related complications © 2016 Wiley Periodicals, Inc. Microsurgery 37:406-409, 2017. © 2016 Wiley Periodicals, Inc.
Tellegen, Anna R; Willems, Nicole; Tryfonidou, Marianna A; Meij, Björn P
2015-12-07
Degenerative lumbosacral stenosis is a common problem in large breed dogs. For severe degenerative lumbosacral stenosis, conservative treatment is often not effective and surgical intervention remains as the last treatment option. The objective of this retrospective study was to assess the middle to long term outcome of treatment of severe degenerative lumbosacral stenosis with pedicle screw-rod fixation with or without evidence of radiological discospondylitis. Twelve client-owned dogs with severe degenerative lumbosacral stenosis underwent pedicle screw-rod fixation of the lumbosacral junction. During long term follow-up, dogs were monitored by clinical evaluation, diagnostic imaging, force plate analysis, and by using questionnaires to owners. Clinical evaluation, force plate data, and responses to questionnaires completed by the owners showed resolution (n = 8) or improvement (n = 4) of clinical signs after pedicle screw-rod fixation in 12 dogs. There were no implant failures, however, no interbody vertebral bone fusion of the lumbosacral junction was observed in the follow-up period. Four dogs developed mild recurrent low back pain that could easily be controlled by pain medication and an altered exercise regime. Pedicle screw-rod fixation offers a surgical treatment option for large breed dogs with severe degenerative lumbosacral stenosis with or without evidence of radiological discospondylitis in which no other treatment is available. Pedicle screw-rod fixation alone does not result in interbody vertebral bone fusion between L7 and S1.
[Torsion of wandering spleen in a teenager: about a case].
Dème, Hamidou; Akpo, Léra Géraud; Fall, Seynabou; Badji, Nfally; Ka, Ibrahima; Guèye, Mohamadou Lamine; Touré, Mouhamed Hamine; Niang, El Hadj
2016-01-01
Wandering or migrating spleen is a rare anomaly which is usually described in children. Complications, which include pedicle torsion, are common and can be life-threatening. We report the case of a 17 year-old patient with a long past medical history of epigastric pain suffering from wandering spleen with chronic torsion of the pedicle. The clinical picture was marked by spontaneously painful epigastric mass, evolved over the past 48 hours. Abdominal ultrasound objectified heterogeneous hypertrophied ectopic spleen in epigastric position and a subcapsular hematoma. Doppler showed a torsion of splenic pedicle which was untwisted 2 turns and a small blood stream on the splenic artery. Abdominal CT scan with contrast injection showed a lack of parenchymal enhancement of large epigastric ectopic spleen and a subcapsular hematoma. The diagnosis of wandering spleen with chronic torsion of the pedicle complicated by necrosis and subcapsular hematoma was confirmed. The patient underwent splenectomy. The postoperative course was uneventful. We here discuss the contribution of ultrasound and CT scan in the diagnosis of wandering spleen with chronic torsion of the pedicle.
Assessment of the viability of skin grafts
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wahner, H.W.
1988-07-01
A number of tests are available to monitor the blood flow in free and distant pedicle skin grafts. The information from these tests aids in the development of measures to enhance vascularization and is occasionally needed to make clinical decisions in patients with distant pedicle grafts. Measurements of the disappearance of an intradermally injected small amount of /sup 133/Xe allows determination of a clearance rate and blood flow before and after clamping the original blood supply through the base. With /sup 99m/Tc, which is generally more readily available, a flow index and block index can be determined. Clinically both proceduresmore » give equally good results in determining a safe time for pedicle base separation. The fluorescein test allows assessment of regional blood flow distribution within the pedicle.« less
Yin, Xinghong; Hu, Wei; Zhang, Xinhai; Sun, Min
2014-10-01
To explore curative effect with pedicle flap of nasal septum-basis nasi and temporal muscucofascial flap to repair nasal septal perforation. Dissecting mucoperichondrium and mucoperioseptum around the perforation and taking dowm and out xia-ward to the floor of nasal cavity to make a inferior extremity pedicle flap. Then,the flap was tumbled and sutured onto raw surface of contralateral side through perforation. Reapplicating autoallergic temporal musculofascial flap to repair another side perforation. Repairing perforation Sin twelve cases were sucessfully healed in endoscope. The pedicle flap of nasal septum-basis nasi and temporal muscucofascial flap is easy to acquire and no rejection. The flap has good blood supplying, high survival rate and provides adequate transplantating materail to repair comparatively large perforation.
Wang, Yingsong; Xie, Jingming; Yang, Zhendong; Zhao, Zhi; Zhang, Ying; Li, Tao; Liu, Luping
2013-07-01
To present the technique of free-hand subaxial cervical pedicle screw (CPS) placement without using intra-operative navigating devices, and to investigate the crucial factors for safe placement and avoidance of lateral pedicle wall perforation, by measuring and classifying perforations with postoperative computed tomography (CT) scan. The placement of CPS has generally been considered as technically demanding and associated with considerable lateral wall perforation rate. For surgeons without access to navigation systems, experience of safe free-hand technique for subaxial CPS placement is especially valuable. A total of 214 consecutive traumatic or degenerative patients with 1,024 CPS placement using the free-hand technique were enrolled. In the operative process, the lateral mass surface was decorticated. Then a small curette was used to identify the pedicle entrance by touching the cortical bone of the medial pedicle wall. It was crucial to keep the transverse angle and make appropriate adjustment with guidance of the resistance of the thick medial cortical bone. The hand drill should be redirected once soft tissue breach was palpated by a slim ball-tip prober. With proper trajectory, tapping, repeated palpation, the 26-30 mm screw could be placed. After the procedure, the transverse angle of CPS trajectory was measured, and perforation of the lateral wall was classified by CT scan: grade 1, perforation of pedicle wall by screw placement, with the external edge of screw deviating out of the lateral pedicle wall equal to or less than 2 mm and grade 2, critical perforation of pedicle wall by screw placement, large than 2 mm. A total of 129 screws (12.64 %) were demonstrated as lateral pedicle wall perforation, of which 101 screws (9.86 %) were classified as grade 1, whereas 28 screws (2.73 %) as grade 2. Among the segments involved, C3 showed an obviously higher perforating rate than other (P < 0.05). The difference between the anatomical pedicle transverse angle and the screw trajectory angle was higher in patients of grade 2 perforation than the others. In the 28 screws of grade 2 perforation verified by axial CT, 26 screws had been palpated as abnormal during operation. However, only 19 out of the 101 screws of grade 1 perforation had shown palpation alarming signs during operation. The average follow-up was 36.8 months (range 5-65 months). There was no symptom and sign of neurovascular injuries. Two screws (0.20 %) were broken, and one screw (0.10 %) loosen. Placement of screw through a correct trajectory may lead to grade 1 perforation, which suggests transversal expansion and breakage of the thinner lateral cortex, probably caused by mismatching of the diameter of 3.5 mm screws and the tiny cancellous bone cavity of pedicle. Grade 1 perforation is deemed as relatively safe to the vertebral artery. Grade 2 perforation means obvious deviation of the trajectory angle of hand drill, which directly penetrates into the transverse foramen, and the risk of vertebral artery injury (VAI) or development of thrombi caused by the irregular blood flow would be much greater compared to grade 1 perforation. Moreover, there are two crucial maneuvers for increasing accuracy of screw placement: identifying the precise entry point using a curette or hand drill to touch the true entrance of the canal after decortication, and guiding CPS trajectory on axial plane by the resistant of thick medial wall.
Tang, Ming-xing; Zhang, Hong-qi; Wang, Yu-xiang; Guo, Chao-feng; Liu, Jin-yang
2016-02-01
Surgical treatment for spinal tuberculosis includes focal tuberculosis debridement, segmental stability reconstruction, neural decompression and kyphotic deformity correction. For the lesions mainly involved anterior and middle column of the spine, anterior operation of debridement and fusion with internal fixation has been becoming the most frequently used surgical technique for the spinal tuberculosis. However, high risk of structural damage might relate with anterior surgery, such as damage in lungs, heart, kidney, ureter and bowel, and the deformity correction is also limited. Due to the organs are in the front of spine, there are less complications in posterior approach. Spinal pedicle screw passes through the spinal three-column structure, which provides more powerful orthopedic forces compared with the vertebral body screw, and the kyphotic deformity correction effect is better in posterior approach. In this paper, we report a 68-year-old male patient with thoracic tuberculosis who underwent surgical treatment by debridement, interbody fusion and internal fixation via posterior approach only. The patient was placed in prone position under general anesthesia. Posterior midline incision was performed, and the posterior spinal construction was exposed. Then place pedicle screw, and fix one side rod temporarily. Make the side of more bone destruction and larger abscess as lesion debridement side. Resect the unilateral facet joint, and retain contralateral structure integrity. Protect the spinal cord, nerve root. Clear sequestrum, necrotic tissue, abscess of paravertebral and intervertebral space. Specially designed titanium mesh cages or bone blocks were implanted into interbody. Fix both side rods and compress both sides to make the mesh cages and bone blocks tight. Reconstruct posterior column structure with allogeneic bone and autologous bone. Using this technique, the procedures of debridement, spinal cord decompression, deformity correction, bone grafting, and internal fixation can be completed with only one incision and surgical position, and the deformity correction efficiency is higher than anterior surgery. © 2016 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.
Srivastava, R C; Srivastava, B P
1976-10-15
A cycle of activity of aldehyde-fuchsin and performic acid-Victoria blue positive granules was observed in the ovarian pedicle of Dysdercus koenigii during the first ovipositional cycle. The quantitative variation of these granules in the pedicle can also be correlated directly with the increase or decrease of the neurosecretory material in the A-type cells of the pars intercerebralis medialis region of the protocerebrum of the brian.
Imagama, Shiro; Ito, Zenya; Wakao, Norimitsu; Ando, Kei; Hirano, Kenichi; Tauchi, Ryoji; Muramoto, Akio; Matsui, Hiroki; Matsumoto, Tomohiro; Sakai, Yoshihito; Katayama, Yoshito; Matsuyama, Yukihiro; Ishiguro, Naoki
2016-10-01
Prospective clinical case series. To describe our surgical procedure and results for posterior correction and fusion with a hybrid approach using pedicle screws, hooks, and ultrahigh-molecular weight polyethylene tape with direct vertebral rotation (DVR) (the PSTH-DVR procedure) for treatment of adolescent idiopathic scoliosis (AIS) with satisfactory correction in the coronal and sagittal planes. Introduction of segmental pedicle screws in posterior surgery for AIS has facilitated good correction and fusion. However, procedures using only pedicle screws have risks during screw insertion, higher costs, and decreased postoperative thoracic kyphosis. We have obtained good outcomes compared with segmental pedicle screw fixation in surgery for AIS using a relatively simple operative procedure (PSTH-DVR) that uses fewer pedicle screws. The subjects were 30 consecutive patients with AIS who underwent the PSTH-DVR procedure and were followed for a minimum of 2 years. Preoperative flexibility, preoperative and postoperative Cobb angles, correction rates, loss of correction, thoracic kyphotic angles (T5-T12), coronal balance, sagittal balance, and shoulder balance were measured on plain radiographs. Rib hump, operation time, estimated blood loss, spinal cord monitoring findings, complications, and scoliosis research society (SRS)-22 scores were also examined. The mean preoperative curve of 58.0 degrees (range, 40-96 degrees) was corrected to a mean of 9.9 degrees postoperatively, and the correction rate was 83.6%. Fusion was obtained in all patients without loss of correction. In 10 cases with preoperative kyphosis angles (T5-T12) <10 degrees, the preoperative mean of 5.8 degrees improved to 20.2 degrees at the final follow-up. Rib hump and coronal, sagittal and shoulder balances were also improved, and good SRS-22 scores were achieved at final follow-up. The correction of deformity with PSTH-DVR is equivalent to that of all-pedicle screw constructs. The procedure gives favorable correction, is advantageous for kyphosis compared with segmental screw fixation, and uses the minimum number of pedicle screws. Therefore, the PSTH-DVR procedure may be useful for treatment of idiopathic scoliosis.
Use of a life-size three-dimensional-printed spine model for pedicle screw instrumentation training.
Park, Hyun Jin; Wang, Chenyu; Choi, Kyung Ho; Kim, Hyong Nyun
2018-04-16
Training beginners of the pedicle screw instrumentation technique in the operating room is limited because of issues related to patient safety and surgical efficiency. Three-dimensional (3D) printing enables training or simulation surgery on a real-size replica of deformed spine, which is difficult to perform in the usual cadaver or surrogate plastic models. The purpose of this study was to evaluate the educational effect of using a real-size 3D-printed spine model for training beginners of the free-hand pedicle screw instrumentation technique. We asked whether the use of a 3D spine model can improve (1) screw instrumentation accuracy and (2) length of procedure. Twenty life-size 3D-printed lumbar spine models were made from 10 volunteers (two models for each volunteer). Two novice surgeons who had no experience of free-hand pedicle screw instrumentation technique were instructed by an experienced surgeon, and each surgeon inserted 10 pedicle screws for each lumbar spine model. Computed tomography scans of the spine models were obtained to evaluate screw instrumentation accuracy. The length of time in completing the procedure was recorded. The results of the latter 10 spine models were compared with those of the former 10 models to evaluate learning effect. A total of 37/200 screws (18.5%) perforated the pedicle cortex with a mean of 1.7 mm (range, 1.2-3.3 mm). However, the latter half of the models had significantly less violation than the former half (10/100 vs. 27/100, p < 0.001). The mean length of time to complete 10 pedicle screw instrumentations in a spine model was 42.8 ± 5.3 min for the former 10 spine models and 35.6 ± 2.9 min for the latter 10 spine models. The latter 10 spine models had significantly less time than the former 10 models (p < 0.001). A life-size 3D-printed spine model can be an excellent tool for training beginners of the free-hand pedicle screw instrumentation.
Tegos, Stergios; Charitidis, Charalampos; Korovessis, Panagiotis G
2014-04-01
Retrospective study on circumferential hybrid instrumentation with posterior lumbar interbody fusion (PLIF) and the novel posterior Universal Clamp (UC) instrumentation. This study evaluated the roentgenographic and clinical outcome after PLIF with PEEK cage augmented with UC posterior sublaminar fixation without posterior fusion. Although UC has been successfully used in scoliosis surgery, to our knowledge, this is the first report on its use in degenerative lumbosacral disease. Rigid pedicle screw lumbosacral fixation is associated with several intraoperative screw-related complications. The use of sublaminar bands and rods combined with PEEK PLIF should increase fusion rate and avoid screw-related complications. From a total of 295 consecutive patients who experienced degenerative lumbosacral disease and received posterior decompression, implantation of PLIF with PEEK cages and semirigid posterior fixation with sublaminar UC bands-rods without posterolateral fusion, 150 patients were eligible for this study with a follow-up of more than 2 years. Interbody fusion rate and global plus segmental sagittal spinal lordosis restoration were recorded pre- and postoperatively. Visual analogue scale and Oswestry Disability Index were used to assess functional outcome. Hybrid instrumentation expanded over 1 to 5 levels. Surgical time ranged from 45 to 225 minutes. Only 12.6% of the patients were transfused. There was no nerve root lesion or deep wound infection. Laminar fracture occurred intraoperatively in one case during band insertion. Interbody fusion was achieved in 94% of the operated segments. Lumbar lordosis improved from -36 ± 9° preoperatively to -53 ± 6° postoperatively. Segmental lordosis improved in L4-L5 segment from -5 ± 3° preoperatively to -12 ± 2° postoperatively and in L5-S1 from -9 ± 4° to -14 ± 2° postoperation. Oswestry Disability Index score improved from 44.9 preoperatively to 2.2 postoperatively (P < 0.001). No patient required further spinal surgery until the final evaluation. UC, a novel semirigid sublaminar posterior instrumentation, combined with wedge-shaped PEEK PLIF corrected both global and segmental sagittal lumbar alignment and achieved fusion rate similar to that historically reported with pedicle screw-PLIF techniques, however, avoiding intraoperative complications associated with the use of pedicle screws.
Plan to procedure: combining 3D templating with rapid prototyping to enhance pedicle screw placement
NASA Astrophysics Data System (ADS)
Augustine, Kurt E.; Stans, Anthony A.; Morris, Jonathan M.; Huddleston, Paul M.; Matsumoto, Jane M.; Holmes, David R., III; Robb, Richard A.
2010-02-01
Spinal fusion procedures involving the implantation of pedicle screws have steadily increased over the past decade because of demonstrated improvement in biomechanical stability of the spine. However, current methods of spinal fusion carries a risk of serious vascular, visceral, and neurological injury caused by inaccurate placement or inappropriately sized instrumentation, which may lead to patient paralysis or even fatality. 3D spine templating software developed by the Biomedical Imaging Resource (BIR) at Mayo Clinic allows the surgeon to virtually place pedicle screws using pre-operative 3D CT image data. With the template plan incorporated, a patient-specific 3D anatomic model is produced using a commercial rapid prototyping system. The pre-surgical plan and the patient-specific model then are used in the procedure room to provide real-time visualization and quantitative guidance for accurate placement of each pedicle screw, significantly reducing risk of injury. A pilot study was conducted at Mayo Clinic by the Department of Radiology, the Department of Orthopedics, and the BIR, involving seven complicated pediatric spine cases. In each case, pre-operative 3D templating was carried out and patient specific models were generated. The plans and the models were used intra-operatively, providing precise pedicle screw starting points and trajectories. Postoperative assessment by the surgeon confirmed all seven operations were successful. Results from the study suggest that patient-specific, 3D anatomic models successfully acquired from 3D templating tools are valuable for planning and conducting pedicle screw insertion procedures.
Sun, C; Huang, G; Christensen, F B; Dalstra, M; Overgaard, S; Bünger, C
1999-05-01
To investigate the differences in bone interface between titanium and stainless steel pedicle screws in the lumbar spine. Eighteen adult mini-pigs that underwent total laminectomy, posterolateral spinal fusion (L4-L5) were randomly selected to receive stainless steel (9) or titanium pedicle screw devices (9). In both groups, the devices were CCD (Sofamore Danek) type with the same size and shape. The postoperative observation time was 3 months. Screws from L4 were harvested along their long axis of pedicle for histomorphometric study. Bone-screw interface and bone volume from thread were examined using linear intercept techniques. Mechanical testing (torsional test and pull-out test) was performed on the screws from L5. The titanium screw group had a significantly higher maximum torque (P < 0.05) and angle related stiffness (P < 0.05) measured by torsional test. In the pull-out tests, no differences were found between the two groups in relation to the maximum load, stiffness and energy to failure. Direct bone contact with the screw in percentage was 29.4% for stainless steel and 43.8% for titanium (P < 0.05). No differences in the bone purchase between the vertebral body part and pedicle part were found. Pedicle screws made of titanium have a better bone-screw interface binding than screws made of stainless steel. Torsional tests are more informative for bone-screw interface study. Pull-out tests seem less valuable when comparing bone purchase of screws made from different materials.
Jiang, Lianghai; Dong, Liang; Tan, Mingsheng; Qi, Yingna; Yang, Feng; Yi, Ping; Tang, Xiangsheng
2017-01-01
Background Atlantoaxial posterior pedicle screw fixation has been widely used for treatment of atlantoaxial instability (AAI). However, precise and safe insertion of atlantoaxial pedicle screws remains challenging. This study presents a modified drill guide template based on a previous template for atlantoaxial pedicle screw placement. Material/Methods Our study included 54 patients (34 males and 20 females) with AAI. All the patients underwent posterior atlantoaxial pedicle screw fixation: 25 patients underwent surgery with the use of a modified drill guide template (template group) and 29 patients underwent surgery via the conventional method (conventional group). In the template group, a modified drill guide template was designed for each patient. The modified drill guide template and intraoperative fluoroscopy were used for surgery in the template group, while only intraoperative fluoroscopy was used in the conventional group. Results Of the 54 patients, 52 (96.3%) completed the follow-up for more than 12 months. The template group had significantly lower intraoperative fluoroscopy frequency (p<0.001) and higher accuracy of screw insertion (p=0.045) than the conventional group. There were no significant differences in surgical duration, intraoperative blood loss, or improvement of neurological function between the 2 groups (p>0.05). Conclusions Based on the results of this study, it is feasible to use the modified drill guide template for atlantoaxial pedicle screw placement. Using the template can significantly lower the screw malposition rate and the frequency of intraoperative fluoroscopy. PMID:28301445
Al-Ruzzeh, Sharif; George, Shane; Bustami, Mahmoud; Nakamura, Koki; Ilsley, Charles; Amrani, Mohamed
2002-05-01
The left internal thoracic artery (LITA) graft to the left anterior descending (LAD) artery became the gold standard graft in coronary surgery. Subsequently, the right internal thoracic artery (RITA) graft was increasingly used. However, there is still some debate about the optimal way of using this conduit. The aim of the present study was to assess our experience in grafting the pedicled RITA graft to LAD in 212 consecutive patients. The records of 212 consecutive patients who underwent isolated coronary artery bypass grafting with the pedicled RITA graft to the LAD artery at Harefield Hospital between January 1998 and May 2001 were retrospectively reviewed. We approached the last 35 consecutive patients to obtain an angiographic control group. All 35 patients (16.5%) consented and, before discharge, underwent angiography to look at the quality of anastomoses and the patency of grafts. Successful catheterization and engagement of the RITA grafts was performed in 32 patients. Angiography showed that 32/32 (100%) of the RITA grafts were widely patent with excellent flow. The distal anastomoses of these RITA grafts were also satisfactory. There were no deaths among the study patients. Our results show that the use of the pedicled RITA graft to the LAD artery provides a good early clinical and angiographic outcome, and suggests that the pedicled RITA graft to the LAD artery is a good alternative to the pedicled LITA graft to the LAD artery.
Choi, Jong Woo; Kim, Young Chul; Oh, Tae Suk; Koh, Kyung S; Jeong, Woo Shik
2017-06-01
Although the perforator free flap is now a standard choice for head and neck reconstruction, problems such as microvascular complications, insufficient volume support for the defect, and fistula formation occur. We revisited a de-epithelialized concept for superficial circumflex iliac artery and anterolateral thigh perforator free flap to overcome these problems. We applied the de-epithelized perforator free flaps in 35 cases among 761 microsurgical head and neck reconstructions and investigated flap characteristics (length gain of pedicle, flap size, and volumetric analysis) and outcomes (flap failure, partial flap necrosis, hematoma, infection, and fistula). Satisfactory results were achieved regarding flap survival, volumetric compensation, and fistula formation. Flaps were transferred successfully in all patients, although 1 patient underwent revisional operation due to venous congestion. Transferred flap volume was significantly higher than the resected tumor volume (p < 0.01), which suggests volume augmentation in the destroyed neck envelope and a protective role against adjuvant radiation. Minor dehiscence and bleeding were seen in two cases, and no other complications were identified. The de-epithelialization concept for perforator free flap is helpful to overcome obstacles related to traditional free flaps in terms of flap survival and volumetric augmentation in head and neck reconstructions. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
A Novel Junctional Tether Weave Technique for Adult Spinal Deformity: 2-Dimensional Operative Video.
Buell, Thomas J; Mullin, Jeffrey P; Nguyen, James H; Taylor, Davis G; Garces, Juanita; Mazur, Marcus D; Buchholz, Avery L; Shaffrey, Mark E; Yen, Chun-Po; Shaffrey, Christopher I; Smith, Justin S
2018-06-05
Proximal junctional kyphosis (PJK) is a common problem after multilevel spine instrumentation for adult spinal deformity. Various anti-PJK techniques such as junctional tethers for ligamentous augmentation have been proposed. We present an operative video demonstrating technical nuances of junctional tether "weave" application. A 70-yr-old male with prior L2-S1 instrumented fusion presented with worsening back pain and posture. Imaging demonstrated pathological loss of lumbar lordosis (flat back deformity), proximal junctional failure, and pseudarthrosis. The patient had severe global and segmental sagittal malalignment, with sagittal vertical axis (SVA, C7-plumbline) measuring 22.3 cm, pelvic incidence (PI) 55°, lumbar lordosis (LL) 8° in kyphosis, pelvic tilt (PT) 30°, and thoracic kyphosis (TK) 6°. The patient gave informed consent for surgery and use of imaging for medical publication. Briefly, surgery first involved re-instrumentation with bilateral pedicle screws from T10 to S1. After right-sided iliac screw fixation (left-sided iliac screw fixation was not performed due to extensive prior iliac crest bone graft harvesting), we then completed a L2-3 Smith-Petersen osteotomy, extended L4 pedicle subtraction osteotomy, and L3-4 interbody arthrodesis with a 12° lordotic cage (9 × 14 × 40 mm). Cobalt Chromium rods were placed spanning the instrumentation bilaterally, and accessory supplemental rods spanning the PSO were attached. An anti-PJK junctional tether "weave" was then implemented using 4.5 mm polyethylene tape (Mersilene tape [Ethicon, Somerville, New Jersey]). Postoperative imaging demonstrated improved alignment (SVA 2.8 cm, PI 55°, LL 53°, PT 25°, TK 45°) and no significant neurological complications occurred during convalescence or at 6 mo postop.
Revascularization procedures for Kienböck disease.
Kakar, Sanjeev; Giuffre, Jennifer L; Shin, Alexander Y
2011-03-01
The goals of treatment in Kienböck disease include preservation of wrist function, maintaining normal wrist kinematics, and revascularization of the necrotic lunate when and if possible. A variety of pedicled vascularized bone graft options exist and include but are not limited to pedicled grafts from the volar radius, dorsal radius, metacarpal heads or bases, and pisiform. Of the various treatment options, pedicled vascularized bone grafts from the dorsal distal radius based on the fourth and fifth extensor compartment arteries has been successful in the revascularization of the necrotic lunate at our institution. Vascularized bone grafting is an attractive alternative to conventional bone grafting by improving the local biological environment and thereby promoting revascularization. Recent advances in the anatomy and physiology of vascularized pedicled bone grafts have increased our ability to apply them to the treatment of Kienböck disease. The purpose of this article is to describe the various types of pedicled vascularized bone graft available, to detail the vascular anatomy of the dorsal distal radius, and to describe the surgical technique of our preferred vascularized bone graft (the fourth+fifth extensor compartment artery graft). In addition, the indications, contraindications, and outcomes are described.
[Comparison of pedicle and free tissue transfers in the German DRG system].
Lotter, O; Stahl, S; Hohenstein, C; Schaller, H-E; Jaminet, P
2011-12-01
Diagnosis-Related Groups (DRGs) are a patient classification system grouping related types of patients to the resources they have consumed. In this analysis, we compared pedicle and free flaps in plastic and reconstructive surgery in the actual German DRG system. After grouping common flaps while systematically modifying the diagnosis, the operative procedure(s), and the receptor site, reimbursement and thresholds of length of stay were identified. The mean value of the average length of stay was higher in free flaps as compared to pedicle flaps (15 vs. 9 days) and the mean reimbursement in free flaps was almost twice as high as in pedicle flaps (8 936 € vs. 4 582 €). Regarding the diagnosis, third-grade open fractures in pedicle flaps and full-thickness burns in free flaps are in the vanguard of reimbursement. Higher DRG conformity is generally found with free flaps. Different possibilities in coding the procedures and the strong dependence on the underlying diagnosis lead to variations of remuneration and length of stay, which are not explainable and sometimes even seem paradoxical. Furthermore, mixed calculation creates DRGs that lose the ability to describe the real effort. © Georg Thieme Verlag KG Stuttgart · New York.
Image Guidance to Aid Pedicle Screw Fixation of a Lumbar Fracture-Dislocation Injury in a Toddler.
Houten, John K; Nahkla, Jonathan; Ghandi, Shashank
2017-09-01
Pedicle screw fixation of the lumbar spine in children age <2 years is particularly challenging, as successful cannulation of the small pedicle dimensions requires a high level of precision and there are no implants specifically designed for the infant spine. Image-guided navigation is commonly used in adult spinal surgery and may be particularly helpful for the placement of spinal screws in areas where the bony anatomy is small and/or anatomically complex, as in the upper cervical area. A 19-month-old female presented with a fracture-dislocation injury of L1-2. Intraoperative imaging using the O-arm multidimensional imaging system was networked to a workstation, and neuronavigation was used to place pedicle instrumentation with 3.5-mm-diameter polyaxial screws designed for posterior cervical fixation. At a 48-month follow-up, the patient was neurologically intact, demonstrated normal physical development, and was engaging in normal physical activity for her age. Radiographs obtained approximately 4 years postsurgery showed no evidence of loss for fixation. Image-guided placement of pedicle screws may be a useful aid in achieving accurate and safe fixation in the small dimensions of the infant spine. Copyright © 2017 Elsevier Inc. All rights reserved.
Exploring the role of 3-dimensional simulation in surgical training: feedback from a pilot study.
Podolsky, Dale J; Martin, Allan R; Whyne, Cari M; Massicotte, Eric M; Hardisty, Michael R; Ginsberg, Howard J
2010-12-01
Randomized control study assessing the efficacy of a pedicle screw insertion simulator. To evaluate the efficacy of an in-house developed 3-dimensional software simulation tool for teaching pedicle screw insertion, to gather feedback about the utility of the simulator, and to help identify the context and role such simulation has in surgical education. Traditional instruction for pedicle screw insertion technique consists of didactic teaching and limited hands-on training on artificial or cadaveric models before guided supervision within the operating room. Three-dimensional computer simulation can provide a valuable tool for practicing challenging surgical procedures; however, its potential lies in its effective integration into student learning. Surgical residents were recruited from 2 sequential years of a spine surgery course. Patient and control groups both received standard training on pedicle screw insertion. The patient group received an additional 1-hour session of training on the simulator using a CT-based 3-dimensional model of their assigned cadaver's spine. Qualitative feedback about the simulator was gathered from the trainees, fellows, and staff surgeons, and all pedicles screws physically inserted into the cadavers during the courses were evaluated through CT. A total of 185 thoracic and lumbar pedicle screws were inserted by 37 trainees. Eighty-two percent of the 28 trainees who responded to the questionnaire and all fellows and staff surgeons felt the simulator to be a beneficial educational tool. However, the 1-hour training session did not yield improved performance in screw placement. A 3-dimensional computer-based simulation for pedicle screw insertion was integrated into a cadaveric spine surgery instructional course. Overall, the tool was positively regarded by the trainees, fellows, and staff surgeons. However, the limited training with the simulator did not translate into widespread comfort with its operation or into improvement in physical screw placement.
A biomechanical analysis of the self-retaining pedicle hook device in posterior spinal fixation
van Laar, Wilbert; Meester, Rinse J.; Smit, Theo H.
2007-01-01
Regular hooks lack initial fixation to the spine during spinal deformity surgery. This runs the risk of posterior hook dislodgement during manipulation and correction of the spinal deformity, that may lead to loss of correction, hook migration, and post-operative junctional kyphosis. To prevent hook dislodgement during surgery, a self-retaining pedicle hook device (SPHD) is available that is made up of two counter-positioned hooks forming a monoblock posterior claw device. The initial segmental posterior fixation strength of a SPHD, however, is unknown. A biomechanical pull-out study of posterior segmental spinal fixation in a cadaver vertebral model was designed to investigate the axial pull-out strength for a SPHD, and compared to the pull-out strength of a pedicle screw. Ten porcine lumbar vertebral bodies were instrumented in pairs with two different instrumentation constructs after measuring the bone mineral density of each individual vertebra. The instrumentation constructs were extracted employing a material testing system using axial forces. The maximum pull-out forces were recorded at the time of the construct failure. Failure of the SPHD appeared in rotation and lateral displacement, without fracturing of the posterior structures. The average pull-out strength of the SPHD was 236 N versus 1,047 N in the pedicle screws (P < 0.001). The pull-out strength of the pedicle screws showed greater correlation with the BMC compared to the SPHD (P < 0.005). The SPHD showed to provide a significant inferior segmental fixation to the posterior spine in comparison to pedicle screw fixation. Despite the beneficial characteristics of the monoblock claw construct in a SPHD, that decreases the risk of posterior hook dislodgement during surgery compared to regular hooks, the SPHD does not improve the pull-out strength in such a way that it may provide a biomechanically solid alternative to pedicle screw fixation in the posterior spine. PMID:17203270
Prichard, George; Weiller, Cornelius; Fritsch, Brita; Reis, Janine
2014-01-01
Noninvasive electrical brain stimulation (NEBS) with transcranial direct current (tDCS) or random noise stimulation (tRNS) applied to the primary motor cortex (M1) can augment motor learning. We tested whether different types of stimulation alter particular aspects of learning a tracing task over three consecutive days, namely skill acquisition (online/within session effects) or consolidation (offline/between session effects). Motor training on a tracing task over three consecutive days was combined with different types and montages of stimulation (tDCS, tRNS). Unilateral M1 stimulation using tRNS as well as unilateral and bilateral M1 tDCS all enhanced motor skill learning compared to sham stimulation. In all groups, this appeared to be driven by online effects without an additional offline effect. Unilateral tDCS resulted in large skill gains immediately following the onset of stimulation, while tRNS exerted more gradual effects. Control stimulation of the right temporal lobe did not enhance skill learning relative to sham. The mechanisms of action of tDCS and tRNS are likely different. Hence, the time course of skill improvement within sessions could point to specific and temporally distinct interactions with the physiological process of motor skill learning. Exploring the parameters of NEBS on different tasks and in patients with brain injury will allow us to maximize the benefits of NEBS for neurorehabilitation. Copyright © 2014 Elsevier Inc. All rights reserved.
Bridwell, Keith H
2006-09-01
Author experience and literature review. To investigate and discuss decision-making on when to perform a Smith-Petersen osteotomy as opposed to a pedicle subtraction procedure and/or a vertebral column resection. Articles have been published regarding Smith-Petersen osteotomies, pedicle subtraction procedures, and vertebral column resections. Expectations and complications have been reviewed. However, decision-making regarding which of the 3 procedures is most useful for a particular spinal deformity case is not clearly investigated. Discussed in this manuscript is the author's experience and the literature regarding the operative options for a fixed coronal or sagittal deformity. There are roles for Smith-Petersen osteotomy, pedicle subtraction, and vertebral column resection. Each has specific applications and potential complications. As the magnitude of resection increases, the ability to correct deformity improves, but also the risk of complication increases. Therein, an understanding of potential applications and complications is helpful.
Kilic, Ali; Denney, Brad; de la Torre, Jorge
2018-05-31
Generally, reconstruction of knee defects with exposed bone, joint, tendon, and/or hardware requires a vascularized muscle flap for coverage. Although there are several surgical options for a knee defect reconstruction, the pedicled gastrocnemius muscle still remains the workhorse flap. Although this flap is commonly used for knee defect reconstruction and the technique is described very well, there is an absence of information in the literature detailing the technique of harvesting and insetting of the gastrocnemius flap step by step with illustrations. The purpose of this article is to describe in detail the technique to reconstruct defects of the knee with pedicled gastrocnemius muscle flap as well as to present demographics and surgical results of 21 patients who had knee reconstruction with a pedicled gastrocnemius muscle flap and split-thickness skin grafting. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Major hepatectomy using the glissonean approach in cases of right umbilical portion
Ome, Yusuke; Kawamoto, Kazuyuki; Park, Tae Bum; Ito, Tadashi
2016-01-01
Right umbilical portion (RUP) is a rare congenital anomaly associated with anomalous ramifications of the hepatic vessels and biliary system. As such, major hepatectomy requires a careful approach. We describe the usefulness of the Glissonean approach in two patients with vessel anomalies, such as RUP. The first patient underwent a right anterior sectionectomy for intrahepatic cholangiocarcinoma. We encircled several Glissonean pedicles that entered the right anterior section along the right side of the RUP. We temporarily clamped each pedicle, confirmed the demarcation area, and finally cut them. The operation was performed safely and was successful. The second patient underwent a left trisectionectomy for perihilar cholangiocarcinoma. We secured the right posterior Glissonean pedicle. The vessels in the pedicle were preserved, and the other vessels and contents were resected. Identifying the vessels for preservation facilitated the safe lymphadenectomy and dissection of the vessels to be resected. We successfully performed the operation. PMID:28008345
The Interaction of Fatigue and Potentiation Following an Acute Bout of Unilateral Squats.
Andrews, Samantha K; Horodyski, Jesse M; MacLeod, Daniel A; Whitten, Joseph; Behm, David G
2016-12-01
A prior conditioning resistance exercise can augment subsequent performance of the affected muscles due to the effects of post-activation potentiation (PAP). The non-local muscle fatigue literature has illustrated the global neural effects of unilateral fatigue. However, no studies have examined the possibility of acute non-local performance enhancements. The objective of the study was to provide a conditioning stimulus in an attempt to potentiate the subsequent jump performance of the affected limb and determine if there were performance changes in the contralateral limb. Using a randomized allocation, 14 subjects (6 females, 8 males) completed three conditions on separate days: 1) unilateral, dominant leg, Bulgarian split squat protocol with testing of the exercised leg, 2) unilateral, dominant leg, Bulgarian split squat protocol with testing of the contralateral, non-exercised leg and 3) control session with testing of the non-dominant leg. Pre- and post-testing consisted of countermovement (CMJ) and drop jumps (DJ). The exercised leg exhibited CMJ height increases of 3.5% (p = 0.008; d = 0.28), 4.0% (p = 0.011; d = 0.33) and 3.2% (p = 0.013; d = 0.26) at 1, 5, and 10 min post-intervention respectively. The contralateral CMJ height had 2.0% (p = 0.034; d = 0.18), 1.2% (p = 0.2; d = 0.12), and 2.1% (p = 0.05; d = 0.17) deficits at 1, 5, and 10 min post-intervention respectively. Similar relative results were found for CMJ power. There were no significant interactions for DJ measures or control CMJ measures. The findings suggest that PAP effects were likely predominant for the exercised leg whereas the conditioning exercise provided trivial magnitude although statistically significant neural impairments for the contralateral limb.
Djugai, S; Boeger, D; Buentzel, J; Esser, D; Hoffmann, K; Jecker, P; Mueller, A; Radtke, G; Bohne, S; Finkensieper, M; Volk, G F; Guntinas-Lichius, O
2014-02-01
Although surgical treatment of patients with chronic vocal cord palsy (VCP) is an integral part of clinical routine of otorhinolaryngologists, there is nearly no population-based data published on incidence and efficiency of this surgery country-wide or nation-wide. 1430 patients with chronic VCP were treated in a department of otorhinolaryngology between 2005 and 2010 in Thuringia, Germany. VCP was unilateral and bilateral in 63 and 18%, respectively. The affected side was not documented in 20%. Iatrogenic lesions of the recurrent nerve (42%) and neoplastic infiltration (27%) were the leading etiologies. 192 patients (13%) received surgical treatment. 31% of patient needed more than one surgery. The rate of surgeries was higher for bilateral VCP (p < 0.0001). Vocal cord augmentation was the most frequent surgery for unilateral VCP and posterior cordectomy for bilateral VCP. The complication rate was high (16%), but not different between unilateral and bilateral VCP (p = 0.108). The risk for tracheostomy was higher in the bilateral VCP group (p < 0.0001). Voice improvement was better after treatment of unilateral VCP (p < 0.0001). Breathing improvement was more frequent after bilateral VCP (p = 0.028). Dysphagia did not improve significantly. The rate of better voice, breathing, and swallowing function was higher in patients treated surgically than without surgery (all p < 0.0001). The rate of patients admitted for treatment of vocal fold palsy was 9.9/100,000 habitants. The surgical rate of VCP was 1.38/100,000 habitants. This population-based analysis shows that surgery for VCP is performed with higher incidence than expected effectively, but with relevant risks in daily routine of otorhinolaryngologists.
Wang, Hui; Ding, Wenyuan; Ma, Lei; Zhang, Lijun; Yang, Dalong
2017-05-01
Evidence regarding whether the polyaxial pedicle screws at the upper instrumented vertebrae (UIV) are superior to monoaxial pedicle screws in prevention of proximal junctional kyphosis (PJK) is not clear. The aim of this study was therefore to explore the influence of different types of pedicle screws at UIV on the incidence of PJK. We reviewed retrospectively 242 patients surgically treated with instrumented segmental posterior spinal fusion at a minimum of 4 motion segments. Polyaxial pedicle screws were used at UIV in 125 patients (polyaxial group), and monoaxial pedicle screws were used at UIV in 117 patients (monoaxial group). According to the occurrence of PJK at final follow-up, patients in both the polyaxial and monoaxial groups were then divided into 2 subgroups: PJK and no proximal junctional kyphosis (NPJK). To investigate the risk factors of PJK, 2 categorized variables were analyzed statistically: 1) patient characteristics: age, sex, body mass index (BMI), bone mineral density (BMD), sagittal vertical axis (SVA), thoracic kyphosis, thoracolumbar junctional angle, lumbar lordosis (LL), pelvic incidence, pelvic tilt, and sacral slope. 2) Surgical variables: Changes of radiographic parameters include the SVA, thoracic kyphosis, thoracolumbar junctional, LL, pelvic incidence, pelvic tilt, sacral slope, pedicle-upper end plate angle, the number of instrumented levels, and the most proximal and distal levels of the instrumentation. PJK was developed in 26 of 117 patients (22.2%) in the monoaxial group and 30 of 125 patients (24.0%) in the polyaxial group. Until the final follow-up, there was no significant difference in the incidence of PJK (χ2 = 0.107, P = 0.734) between the monoaxial and polyaxial groups. There was no significant difference in patient characteristics and surgical variables between the 2 groups, except the proximal junctional angle change (P = 0.031). In the monoaxial group, there were no significant differences in patient characteristics between the PJK and NPJK subgroups, except BMI (P = 0.042) and BMD (P = 0.037). There were no significant differences in change of radiographic parameters, except SVA change (P = 0.036), proximal junctional angle change (P = 0.029), LL change (P = 0.025), and lower instrumented vertebrae location (P = 0.036). Multivariate logistic regression analysis revealed that obesity, osteoporosis, lower instrumented vertebra at sacrum, and LL change >10 degrees were independently associated with PJK. In the polyaxial group, there were no significant differences in patient characteristics between the PJK and NPJK subgroups, except BMI (P = 0.032) and BMD (P = 0.040). There were no significant differences in change of radiographic parameters between the PJK and NPJK subgroups, except P-UP angle (P = 0.037) and lower instrumented vertebrae location (P = 0.017). Multivariate logistic regression analysis revealed that obesity, osteoporosis, and lower instrumented vertebra at sacrum were independently associated with PJK. Polyaxial pedicle screws at UIV is not superior to monoaxial pedicle screws in prevention of PJK. Obesity, osteoporosis, and lower instrumented vertebra at sacrum are risk factors for PJK in all the patients. Excessive LL reconstruction is the unique risk factor of PJK when monoaxial pedicle screws were used at UIV. Copyright © 2017 Elsevier Inc. All rights reserved.
Liebsch, Christian; Zimmermann, Julia; Graf, Nicolas; Schilling, Christoph; Wilke, Hans-Joachim; Kienle, Annette
2018-01-01
Biomechanical in vitro tests analysing screw loosening often include high standard deviations caused by high variabilities in bone mineral density and pedicle geometry, whereas standardized mechanical models made of PU foam often do not integrate anatomical or physiological boundary conditions. The purpose of this study was to develop a most realistic mechanical model for the standardized and reproducible testing of pedicle screws regarding the resistance against screw loosening and the holding force as well as to validate this model by in vitro experiments. The novel mechanical testing model represents all anatomical structures of a human vertebra and is consisting of PU foam to simulate cancellous bone, as well as a novel pedicle model made of short carbon fibre filled epoxy. Six monoaxial cannulated pedicle screws (Ø6.5 × 45mm) were tested using the mechanical testing model as well as human vertebra specimens by applying complex physiological cyclic loading (shear, tension, and bending; 5Hz testing frequency; sinusoidal pulsating forces) in a dynamic materials testing machine with stepwise increasing load after each 50.000 cycles (100.0N shear force + 20.0N per step, 51.0N tension force + 10.2N per step, 4.2Nm bending moment + 0.8Nm per step) until screw loosening was detected. The pedicle screw head was fixed on a firmly clamped rod while the load was applied in the vertebral body. For the in vitro experiments, six human lumbar vertebrae (L1-3, BMD 75.4 ± 4.0mg/cc HA, pedicle width 9.8 ± 0.6mm) were tested after implanting pedicle screws under X-ray control. Relative motions of pedicle screw, specimen fixture, and rod fixture were detected using an optical motion tracking system. Translational motions of the mechanical testing model experiments in the point of load introduction (0.9-2.2mm at 240N shear force) were reproducible within the variation range of the in vitro experiments (0.6-3.5mm at 240N shear force). Screw loosening occurred continuously in each case between 140N and 280N, while abrupt failures of the specimen were observed only in vitro. In the mechanical testing model, no translational motion was detected in the screw entry point, while in vitro, translational motions of up to 2.5mm in inferior direction were found, leading to a slight shift of the centre of rotation towards the screw tip. Translational motions of the screw tip of about 5mm in superior direction were observed both in vitro and in the mechanical testing model, while they were continuous in the mechanical testing model and rapidly increasing after screw loosening initiation in vitro. The overall pedicle screw loosening characteristics were qualitatively and quantitatively similar between the mechanical testing model and the human vertebral specimens as long as there was no translation of the screw at the screw entrance point. Therefore, the novel mechanical testing model represents a promising method for the standardized testing of pedicle screws regarding screw loosening for cases where the screw rotates around a point close to the screw entry point. Copyright © 2017 Elsevier Ltd. All rights reserved.
Kim, Jun Young; Kwon, Jae Yeol; Kim, Moon Seok; Lee, Jeong Jae; Kim, Il Sup; Hong, Jae Taek
2018-03-01
To compare the morphometry of subaxial cervical spine between cerebral palsy (CP) and normal control. We retrospectively analyzed 72 patients with CP, as well as 72 patients from normal population. The two groups were matched for age, sex, and body mass index. Pedicle, lateral mass (LM), and vertebral foramen were evaluated using computed tomography (CT) imaging. Pedicle diameter, LM height, thickness, width and vertebral foramen asymmetry (VFA) were measured and compared between the two groups. Cervical dynamic motion, disc and facet joint degeneration were investigated. Additionally, we compared the morphology of LM between convex side and concave side with cervical scoliotic CP patients. LM height was smaller in CP group. LM thickness and width were larger in CP group at mid-cervical level. In 40 CP patients with cervical scoliosis, there were no height and width differences between convex and concave side. Pedicle outer diameter was not statistically different between two groups. Pedicle inner diameter was significantly smaller in CP group. Pedicle sclerosis was more frequent in CP patients. VFA was larger in CP group at C3, C4, and C5. Disc/facet degeneration grade was higher in the CP group. Cervical motion of CP group was smaller than those of the control group. LM morphology of CP patients was different from normal population. Sclerotic pedicles and vertebral foramen asymmetry were more commonly identified in CP patients. CP patients were more likely to demonstrate progressive disc/facet degeneration. This data may provide useful information on cervical posterior instrumentation in CP patients.
Tan, Shane; Yek, Jacklyn; Ong, Wei Chen; Hing, Chor Hoong; Lim, Thiam Chye
2013-01-01
Background Our objective was to compare the complication rates of two common breast reconstruction techniques performed at our hospital and the cost-effectiveness for each test group. Methods All patients who underwent deep inferior epigastric perforator (DIEP) flap and transverse rectus abdominis myocutaneous (TRAM) flap by the same surgeon were selected and matched according to age and mastectomy with or without axillary clearance. Patients from each resultant group were selected, with the patients matched chronologically. The remainder were matched for by co-morbidities. Sixteen patients who underwent immediate breast reconstruction with pedicled TRAM flaps and 16 patients with DIEP flaps from 1999 to 2006 were accrued. The average total hospitalisation cost, length of hospitalisation, and complications in the 2 year duration after surgery for each group were compared. Results Complications arising from both the pedicled TRAM flaps and DIEP flaps included fat necrosis (TRAM, 3/16; DIEP, 4/16) and other minor complications (TRAM, 3/16; DIEP, 1/16). The mean hospital stay was 7.13 days (range, 4 to 12 days) for the pedicled TRAM group and 7.56 (range, 5 to 10 days) for the DIEP group. Neither the difference in complication rates nor in hospital stay duration were statistically significant. The total hospitalisation cost for the DIEP group was significantly higher than that of the pedicled TRAM group (P<0.001). Conclusions Based on our study, the pedicled TRAM flap remains a cost-effective technique in breast reconstruction when compared to the newer, more expensive and tedious DIEP flap. PMID:23730591
The Omental Pedicle Flap in Dogs Revised and Refined: A Cadaver Study.
Doom, Marjan; Cornillie, Pieter; Simoens, Paul; Huyghe, Stephanie; de Rooster, Hilde
2016-08-01
To expand current knowledge on the canine omental vasculature and refine the existing lengthening technique of the canine omentum. Ex vivo study. Canine cadavers (n=20). In 10 canine cadavers the omental arteries were mapped using intravascular latex injection and these results were used to create an omental pedicle flap based on the splenic artery in 10 additional cadavers. The operating range of the flap was recorded with particular attention to the main regions of interest for omental transposition in dogs (axillary and inguinal regions). The superficial and deep omental leaves were each predominantly supplied by a left and a right marginal omental artery that anastomosed near the caudal omental border into a superficial and a deep omental arch, respectively. Anastomoses between arteries of the superficial and the deep omental leaves were weak and inconsistent, except for 1 anastomosis that was found in 8 of 10 dogs. By transposing the intact omentum, the right axilla could be reached in 3 dogs, both axillae in 1 dog, and both groins in all cadavers. In all cases, the omental pedicle reached to and beyond the axillary and inguinal regions. By unfolding the pedicle leaves, the width of the pedicle tip could be doubled. When lengthening the omentum is necessary to reach extra-abdominal structures, the omental pedicle flap based on the splenic artery appears to preserve the omental vascular supply. These observations warrant further clinical trials to evaluate this new omtental flap technique in vivo. © Copyright 2016 by The American College of Veterinary Surgeons.
Sadigh, Parviz L; Chang, Li-Ren; Hsieh, Ching-Hua; Feng, Wen-Jui; Jeng, Seng-Feng
2014-09-01
The trapezius myocutaneous flap is an established reconstructive option in head and neck cases The authors present their experience with 10 trapezius perforator flaps, all raised using a freestyle technique of perforator dissection, to successfully reconstruct both local and distant soft-tissue defects. Ten patients underwent soft-tissue reconstruction using trapezius perforator flaps. After mapping the perforator with a handheld Doppler device at the intersection of a horizontal line drawn 6 to 8 cm inferior to the scapular spine and a vertical line drawn 8 to 9 cm lateral to the midline of the back, perforator flaps were raised in a freestyle fashion, with complete preservation of the trapezius muscle. The flap can be pedicled into local defects or transferred as a free flap. Six flaps were elevated as pedicled flaps and four were transferred as free flaps. Flap size ranged from 6 × 4 cm to 25 × 15 cm. The pedicle length ranged from 4 to 14 cm. The pedicle originated from the dorsal scapular artery. In one case, the authors converted from a pedicled flap to a free flap secondary to insufficient pedicle length. All donor sites were closed directly. The follow-up period ranged from 4 months to 4 years. All of the flaps survived completely with no major complications, and no patients developed any shoulder dysfunction. The trapezius perforator flap is a reliable and versatile reconstructive option that can be used to repair both local and distant soft-tissue defects. The donor-site morbidity is minimal. Therapeutic, IV.
Leisser, Christoph; Hirnschall, Nino; Döller, Birgit; Varsits, Ralph; Ullrich, Marlies; Kefer, Katharina; Findl, Oliver
2018-03-01
Classical or temporal internal limiting membrane (ILM) flap transposition with air or gas tamponade are current trends with the potential to improve surgical results, especially in cases with large macular holes. A prospective case series included patients with idiopathic macular holes or persistent macular holes after 23-G pars plana vitrectomy (PPV) and ILM peeling with gas tamponade. In all patients, 23-G PPV and ILM peeling with ILM flap transposition with gas tamponade and postoperative face-down position was performed. In 7 of 9 eyes, temporal ILM flap transposition combined with pedicle ILM flap could be successfully performed and macular holes were closed in all eyes after surgery. The remaining 2 eyes were converted to pedicle ILM flap transposition with macular hole closure after surgery. Three eyes were scheduled as pedicle ILM flap transposition due to previous ILM peeling. In 2 of these eyes, the macular hole could be closed with pedicle ILM flap transposition. In 3 eyes, free ILM flap transposition was performed and in 2 of these eyes macular hole could be closed after surgery, whereas in 1 eye a second surgery, performed as pedicle ILM flap transposition, was performed and led to successful macular hole closure. Use of ILM flaps in surgical repair of macular hole surgery is a new option of treatment with excellent results independent of the diameter of macular holes. For patients with persistent macular holes, pedicle ILM flap transposition or free ILM flap transposition are surgical options.
Shittu, O B; Sotunmbi, P T
2015-06-01
Urethroplasty is often required for long urethral strictures or urethral strictures that have recurred after repeated urethral dilatations or urethrotomy. The transvers penile skin pedicled flap is very versatile for the reconstruction of long urethral stricture. However the meticulous sharp dissection required to develop it takes a long time to do and may be associated with button hole injuries to the vascular pedicle and the penile skin. We describe a simplified technique of raising the flap which does not require sharp dissection and is very quick to accomplish. Technique involves using a circumcising distal penile shaft skin incision to de-glove the penis by blunt dissection. The skin substitute, adequate to give appropriate urethra calibre is similarly dissected bluntly along with its vascular pedicle from the proximal penile skin. The techniques used to facilitate successful blunt dissection are described. In 9 adults with long, multiple urethral strictures, the average time to develop the flap was 15 minutes and complication have been limited to temporary urethro-cutaneous fistula at the ventral part of the circular skin closure. These fistulae closed on conservative treatment. No patient suffered button-hole injuries to either the vascular pedicle or the penile skin. This modification to the standard sharp dissection is very quick to accomplish. It also avoids the creation of button-hole injuries to either the vascular pedicle or the penile skin. It should make the use of this versatile flap more attractive in the reconstruction of long urethral strictures in those who may wish to use this option for reconstruction of long urethral strictures.
Near-infrared imaging of face transplants: are both pedicles necessary?
Nguyen, John T; Ashitate, Yoshitomo; Venugopal, Vivek; Neacsu, Florin; Kettenring, Frank; Frangioni, John V; Gioux, Sylvain; Lee, Bernard T
2013-09-01
Facial transplantation is a complex procedure that corrects severe facial defects due to traumas, burns, and congenital disorders. Although face transplantation has been successfully performed clinically, potential risks include tissue ischemia and necrosis. The vascular supply is typically based on the bilateral neck vessels. As it remains unclear whether perfusion can be based off a single pedicle, this study was designed to assess perfusion patterns of facial transplant allografts using near-infrared (NIR) fluorescence imaging. Upper facial composite tissue allotransplants were created using both carotid artery and external jugular vein pedicles in Yorkshire pigs. A flap validation model was created in n = 2 pigs and a clamp occlusion model was performed in n = 3 pigs. In the clamp occlusion models, sequential clamping of the vessels was performed to assess perfusion. Animals were injected with indocyanine green and imaged with NIR fluorescence. Quantitative metrics were assessed based on fluorescence intensity. With NIR imaging, arterial perforators emitted fluorescence indicating perfusion along the surface of the skin. Isolated clamping of one vascular pedicle showed successful perfusion across the midline based on NIR fluorescence imaging. This perfusion extended into the facial allograft within 60 s and perfused the entire contralateral side within 5 min. Determination of vascular perfusion is important in microsurgical constructs as complications can lead to flap loss. It is still unclear if facial transplants require both pedicles. This initial pilot study using intraoperative NIR fluorescence imaging suggests that facial flap models can be adequately perfused from a single pedicle. Copyright © 2013 Elsevier Inc. All rights reserved.
Hacquebord, Jacques H; Hanel, Douglas P; Friedrich, Jeffrey B
2017-08-01
The pedicled latissimus flap has been shown to provide effective coverage of wounds around the elbow with an average size of 100 to 147 cm 2 but with complication rates of 20% to 57%. We believe the pedicled latissimus dorsi flap is an effective and safe technique that provides reliable and durable coverage of considerably larger soft tissue defects around the elbow and proximal forearm. A retrospective review was performed including all patients from Harborview Medical Center between 1998 and 2012 who underwent coverage with pedicled latissimus dorsi flap for defects around the elbow. Demographic information, injury mechanism, soft tissue defect size, complications (minor vs major), and time to surgery were collected. The size of the soft tissue defect, complications, and successful soft tissue coverage were the primary outcome measures. A total of 18 patients were identified with variable mechanisms of injury. Average defect size around the elbow was 422 cm 2 . Three patients had partial necrosis of the distal most aspect of the flap, which was treated conservatively. One patient required a secondary fasciocutaneous flap, and another required conversion to a free latissimus flap secondary to venous congestion. Two were lost to follow-up after discharge from the hospital. In all, 88% (14 of 16) of the patients had documented (>3-month follow-up) successful soft tissue coverage with single-stage pedicled latissimus dorsi flap. The pedicled latissimus dorsi flap is a reliable option for large and complex soft tissue injuries around the elbow significantly larger than previous reports. However, coverage of the proximal forearm remains challenging.
Dixon, Daniel; Darden, Bruce; Casamitjana, Jose; Weissmann, Karen A; Cristobal, San; Powell, David; Baluch, Daniel
2017-04-01
A fresh frozen cadaver study was conducted. To report the cortical breach rate using the dynamic surgical guidance (DSG) probe versus traditional freehand technique for cervical lateral mass, cervical pedicle and cervical laminar screws. Nine male fresh frozen cadaveric torsos were utilized for this study. Each investigator was assigned three specimens that were randomized by fixation point, side and order of technique for establishing a screw pilot hole. The technique for screw hole preparation utilized was either a DSG probe in the "on" mode or in the "off" mode using a freehand technique popularized by Lenke et al. Levels instrumented included C1 lateral mass, C2 pedicle screws and lamina screws, and C6-T1 pedicle screws. Fluoroscopy and other navigational assistance were not used for screw hole preparation or screw insertion. All specimens were CT imaged following insertion of all screws. A senior radiologist evaluated all scans and determined that a misplaced screw was a breach of ≥2 mm. A total of 104 drillings were performed, 52 with DSG and 52 without DSG There were 68 total pedicle drillings, 34 in each group. There were 18 drillings in the lamina and lateral mass. There was no significant difference between surgeons or between the left and right side. All breaches were in the pedicle, and none in the lamina or lateral mass. The breach rate for PG "on" was 6/68 = 8.96% (95% CI 3.69, 19.12%). The breach rate for PG "off" was 20/68 = 29.41% (95% CI 19.30, 41.87%). Of the 20 pedicle breaches in the non-DSG group, 7 were lateral and superior, 8 were lateral, 4 medial and 1 inferior. Of the six pedicle breaches in the DSG group, two were lateral/superior, two were lateral and two were medial in the pedicle. The dynamic surgical guidance probe is a safe tool to assist the surgeon with screw placement in the cervical spine. Additionally, the DSG potentially avoids the cumulative risks associated with fluoroscopy and provides real-time feedback to the surgeon allowing correction at the time of breach. Level of evidence Level IV.
Tsuang, Fon-Yih; Chen, Chia-Hsien; Kuo, Yi-Jie; Tseng, Wei-Lung; Chen, Yuan-Shen; Lin, Chin-Jung; Liao, Chun-Jen; Lin, Feng-Huei; Chiang, Chang-Jung
2017-09-01
Minimally invasive spine surgery has become increasingly popular in clinical practice, and it offers patients the potential benefits of reduced blood loss, wound pain, and infection risk, and it also diminishes the loss of working time and length of hospital stay. However, surgeons require more intraoperative fluoroscopy and ionizing radiation exposure during minimally invasive spine surgery for localization, especially for guidance in instrumentation placement. In addition, computer navigation is not accessible in some facility-limited institutions. This study aimed to demonstrate a method for percutaneous screws placement using only the anterior-posterior (AP) trajectory of intraoperative fluoroscopy. A technical report (a retrospective and prospective case series) was carried out. Patients who received posterior fixation with percutaneous pedicle screws for thoracolumbar degenerative disease or trauma comprised the patient sample. We retrospectively reviewed the charts of consecutive 670 patients who received 4,072 pedicle screws between December 2010 and August 2015. Another case series study was conducted prospectively in three additional hospitals, and 88 consecutive patients with 413 pedicle screws were enrolled from February 2014 to July 2016. The fluoroscopy shot number and radiation dose were recorded. In the prospective study, 78 patients with 371 screws received computed tomography at 3 months postoperatively to evaluate the fusion condition and screw positions. In the retrospective series, the placement of a percutaneous screw required 5.1 shots (2-14, standard deviation [SD]=2.366) of AP fluoroscopy. One screw was revised because of a medialwall breach of the pedicle. In the prospective series, 5.8 shots (2-16, SD=2.669) were required forone percutaneous pedicle screw placement. There were two screws with a Grade 1 breach (8.6%), both at the lateral wall of the pedicle, out of 23 screws placed at the thoracic spine at T9-T12. Forthe lumbar and sacral areas, there were 15 Grade 1 breaches (4.3%), 1 Grade 2 breach (0.3%), and 1 Grade 3 breach (0.3%). No revision surgery was necessary. This method avoids lateral shots of fluoroscopy during screw placement and thus decreases the operation time and exposes surgeons to less radiation. At the same time, compared with the computer-navigated procedure, it is less facility-demanding, and provides satisfactory reliability and accuracy. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Accuracy of pedicle screw placement in patients with Marfan syndrome.
Qiao, Jun; Zhu, Feng; Xu, Leilei; Liu, Zhen; Sun, Xu; Qian, Bangping; Jiang, Qing; Zhu, Zezhang; Qiu, Yong
2017-03-21
There is no study concerning safety and accuracy of pedicle screw placement in Marfan syndrome. The objective of this study is to investigate accuracy and safety of pedicle screw placement in scoliosis associated with Marfan syndrome. CT scanning was performed to analyze accuracy of pedicle screw placement. Pedicle perforations were classified as medial, lateral or anterior and categorized to four grades: ≤ 2 mm as Grade 1, 2.1-4.0 mm as Grade 2, 4.1-6.0 mm as Grade 3, ≥6.1 mm as Grade 4. Fully contained screws or with medial wall perforation ≤ 2 mm or with lateral wall perforation ≤ 6 mm and without injury of visceral organs were considered acceptable, otherwise were unacceptable. 976 pedicle screws were placed, 713 screws (73.1%) were fully contained within the cortical boundaries of the pedicle. 924 (94.7%) screws were considered as acceptable, and 52 (5.3%) as unacceptable. The perforation rate was higher using free-hand technique than O-arm navigation technique (30.8% VS. 11.4%, P < 0.05), higher in lumbar region than in thoracic region (34.1% VS. 22.3%, P < 0.05) and higher in concave side than in convex side (33.5% VS. 21.9%, P < 0.05). No injury of visceral organs especially aorta erosion was noted in the series. 7 cases of dural tear caused by misplaced screws occurred, and 4 cases developed cerebro-spinal fluid leak. Drainage and pressure dressings were applied for these patients, and no infection was observed. Leg pain was observed in 7 cases, and 2 cases simultaneously complained of leg weakness. Revision surgery was conducted to remove the misplaced screws for these 2 patients. Conservative treatment was applied for the 5 patients without leg weakness. Symptoms of leg weakness and pain resolved in all patients. Placement of pedicle screw in Marfan syndrome is accuracy and safe. O-arm navigation was an effective modality to ensure the safety and accuracy of screw placement. Special attention should be paid when screws were placed at the lumber spine and the concave side of spine deformity to avoid the higher rate of complications.
Pedicle screw versus hybrid posterior instrumentation for dystrophic neurofibromatosis scoliosis.
Wang, Jr-Yi; Lai, Po-Liang; Chen, Wen-Jer; Niu, Chi-Chien; Tsai, Tsung-Ting; Chen, Lih-Huei
2017-06-01
Surgical management of severe rigid dystrophic neurofibromatosis (NF) scoliosis is technically demanding and produces varying results. In the current study, we reviewed 9 patients who were treated with combined anterior and posterior fusion using different types of instrumentation (i.e., pedicle screw, hybrid, and all-hook constructs) at our institute.Between September 2001 and July 2010 at our institute, 9 patients received anterior release/fusion and posterior fusion with different types of instrumentation, including a pedicle screw construct (n = 5), a hybrid construct (n = 3), and an all-hook construct (n = 1). We compared the pedicle screw group with the hybrid group to analyze differences in preoperative curve angle, immediate postoperative curve reduction, and latest follow-up curve angle.The mean follow-up period was 9.5 ± 2.9 years. The average age at surgery was 10.3 ± 3.9 years. The average preoperative scoliosis curve was 61.3 ± 13.8°, and the average preoperative kyphosis curve was 39.8 ± 19.7°. The average postoperative scoliosis and kyphosis curves were 29.7 ± 10.7° and 21.0 ± 13.5°, respectively. The most recent follow-up scoliosis and kyphosis curves were 43.4 ± 17.3° and 29.4 ± 18.9°, respectively. There was no significant difference in the correction angle (either coronal or sagittal), and there was no significant difference in the loss of sagittal correction between the pedicle screw construct group and the hybrid construct group. However, the patients who received pedicle screw constructs had significantly less loss of coronal correction (P < .05). Two patients with posterior instrumentation, one with an all-hook construct and the other with a hybrid construct, required surgical revision because of progression of deformity.It is difficult to intraoperatively correct dystrophic deformity and to maintain this correction after surgery. Combined anterior release/fusion and posterior fusion using either a pedicle screw construct or a hybrid construct provide similar curve corrections both sagittally and coronally. After long-term follow-up, sagittal correction was maintained with both constructs. However, patients treated with posterior instrumentation using pedicle screw constructs had significantly less loss of coronal correction.
Pedicle screw versus hybrid posterior instrumentation for dystrophic neurofibromatosis scoliosis
Wang, Jr-Yi; Lai, Po-Liang; Chen, Wen-Jer; Niu, Chi-Chien; Tsai, Tsung-Ting; Chen, Lih-Huei
2017-01-01
Abstract Surgical management of severe rigid dystrophic neurofibromatosis (NF) scoliosis is technically demanding and produces varying results. In the current study, we reviewed 9 patients who were treated with combined anterior and posterior fusion using different types of instrumentation (i.e., pedicle screw, hybrid, and all-hook constructs) at our institute. Between September 2001 and July 2010 at our institute, 9 patients received anterior release/fusion and posterior fusion with different types of instrumentation, including a pedicle screw construct (n = 5), a hybrid construct (n = 3), and an all-hook construct (n = 1). We compared the pedicle screw group with the hybrid group to analyze differences in preoperative curve angle, immediate postoperative curve reduction, and latest follow-up curve angle. The mean follow-up period was 9.5 ± 2.9 years. The average age at surgery was 10.3 ± 3.9 years. The average preoperative scoliosis curve was 61.3 ± 13.8°, and the average preoperative kyphosis curve was 39.8 ± 19.7°. The average postoperative scoliosis and kyphosis curves were 29.7 ± 10.7° and 21.0 ± 13.5°, respectively. The most recent follow-up scoliosis and kyphosis curves were 43.4 ± 17.3° and 29.4 ± 18.9°, respectively. There was no significant difference in the correction angle (either coronal or sagittal), and there was no significant difference in the loss of sagittal correction between the pedicle screw construct group and the hybrid construct group. However, the patients who received pedicle screw constructs had significantly less loss of coronal correction (P < .05). Two patients with posterior instrumentation, one with an all-hook construct and the other with a hybrid construct, required surgical revision because of progression of deformity. It is difficult to intraoperatively correct dystrophic deformity and to maintain this correction after surgery. Combined anterior release/fusion and posterior fusion using either a pedicle screw construct or a hybrid construct provide similar curve corrections both sagittally and coronally. After long-term follow-up, sagittal correction was maintained with both constructs. However, patients treated with posterior instrumentation using pedicle screw constructs had significantly less loss of coronal correction. PMID:28562548
Design of Mini Latissimus Dorsi Flap Based on Thoracodorsal Vascular Patterns.
Elzawawy, Ehab Mostafa; Kelada, Melad Naim; Al Karmouty, Ahmed Farouk
2018-06-01
Latissimus dorsi (LD) flap has been used for reconstructive purposes in oncoplastic breast surgery. Using large part of the muscle as a flap leads to a residual functional loss. Muscle sparing and mini LD flaps can be used with no functional sequelae. However, the design of such flap presents a challenge. Twenty cadavers were dissected on both sides to identify the different vascular patterns of the thoracodorsal (TD) pedicle. The vessels were counted, and the following measurements were taken: diameter, length, distance from inferior angel of scapula, and vertebral level. Data were collected and entered into the personal computer. Statistical analysis was done using (SPSS/version 20) software. Five vascular patterns of TD pedicle were found. Type 1: a long vertically descending pedicle giving 3 to 4 transverse medial branches to LD in 40%. Type 2: a short pedicle terminating into 1 to 2 serratus anterior collaterals and 1 to 2 transverse lateral branches to LD in 10%. Type 3: a long vertically descending pedicle giving 2 to 3 small lateral branches to upper part of LD and terminating into medial and lateral branches in the lower part of LD in 10%. Type 4: a short pedicle that gives 4 to 5 terminal branches to LD, one of them is a long vertically descending branch to lower part of LD in 20%. Type 5: a short pedicle that terminates into a transverse medial and a long vertical branch to LD in 20%. The classically described pattern of TD pedicle (type 5) was found in 20% of cases, whereas the most commonly found pattern was type 1. This means that the pattern of TD branching is unpredictable, and a preoperative ultrasound is essential to define the existing pattern and plan the best LD flap design for each patient. In types 1 and 5, the flap can be designed using the transverse medial branch or branches. In type 2, one of the lateral transverse branches can be used. In types 3, 4, and 5, the long descending vertical branch can be used. It has a sizeable diameter (1.80.23 mm), length (12.31.64 cm), and can be located 6.50.96 cm below the inferior angle of scapula.
Morphometric study of the true S1 and S2 of the normal and dysmorphic sacralized sacra.
Firat, Ayşegül; Alemdaroğlu, Kadir Bahadır; Özmeriç, Ahmet; Yücens, Mehmet; Göksülük, Dinçer
2017-06-12
This study aimed to generate data for the S1 and S2 alar pedicle and body and the alar orientations for both dysmorphic and normal sacra. The study comprised two groups: Group N consisted of 53 normal sacra and Group D included 10 dysmorphic sacra. Various features such as alar pedicle circumference; anterior, middle, and posterior axis of the sacral ala; sacral body height and width; and sagittal thickness were measured. In group N, the median anterior axis of the alae was observed to be 30° on the right and 25° on the left, the median midline axis was found to be 20° on the right and 15° on the left, and the median posterior alar axis was -15° on the right and -20° on the left. The true S1 and S2 alar pedicle circumferences were observed to be significantly smaller in group D, which demonstrated a shorter S1 alar pedicle mean circumference, significantly narrower S1 body mean width, and considerably tapered sagittal thickness. Our analysis indicated that dysmorphic sacra have a lower sagittal thickness and width of bodies and smaller alar pedicles, which explains the difficulties in their percutaneous fixation.
Park, Jun Hyung; Eun, Suk Chan; Lee, Jong Hoon; Hong, Sung Hee; Kim, Chin Whan
2012-01-01
We experienced satisfactory outcomes by synchronously transplanting an artery and vein using an anterolateral thigh flap pedicle between the vascular pedicle and recipient vessel of a flap for scalp reconstruction. A 45-year-old man developed a subdural hemorrhage due to a fall injury. In this patient, the right temporal cranium was missing and the patient had 4×3 cm and 6×5 cm scalp defects. We planned a scalp reconstruction using a latissimus dorsi free flap. Intraoperatively, there was a severe injury to the right superficial temporal vessel because of previous neurosurgical operations. A 15 cm long pedicle defect was needed to reach the recipient facial vessels. For the vascular graft, the descending branch of the lateral circumflex femoral artery and two venae comitantes were harvested. The flap survived well and the skin graft was successful with no notable complications. When an interposition graft is needed in the reconstruction of the head and neck region for which mobility is mandatory to a greater extent, a sufficient length of graft from an anterolateral flap pedicle could easily be harvested. Thus, this could contribute to not only resolving the disadvantages of a venous graft but also to successfully performing a vascular anastomosis. PMID:22783493
Fan, Yong; Du, Jin Peng; Liu, Ji Jun; Zhang, Jia Nan; Qiao, Huan Huan; Liu, Shi Chang; Hao, Ding Jun
2018-06-01
A miniature spine-mounted robot has recently been introduced to further improve the accuracy of pedicle screw placement in spine surgery. However, the differences in accuracy between the robotic-assisted (RA) technique and the free-hand with fluoroscopy-guided (FH) method for pedicle screw placement are controversial. A meta-analysis was conducted to focus on this problem. Several randomized controlled trials (RCTs) and cohort studies involving RA and FH and published before January 2017 were searched for using the Cochrane Library, Ovid, Web of Science, PubMed, and EMBASE databases. A total of 55 papers were selected. After the full-text assessment, 45 clinical trials were excluded. The final meta-analysis included 10 articles. The accuracy of pedicle screw placement within the RA group was significantly greater than the accuracy within the FH group (odds ratio 95%, "perfect accuracy" confidence interval: 1.38-2.07, P < .01; odds ratio 95% "clinically acceptable" Confidence Interval: 1.17-2.08, P < .01). There are significant differences in accuracy between RA surgery and FH surgery. It was demonstrated that the RA technique is superior to the conventional method in terms of the accuracy of pedicle screw placement.
Chen, Zhong-hui; Chen, Xi; Zhu, Ze-zhang; Wang, Bin; Qian, Bang-ping; Zhu, Feng; Sun, Xu; Qiu, Yong
2015-07-01
Use of pedicle screws has been popularized in the treatment of pediatric spinal deformity. Despite many studies regarding the effect of pedicle screws on the immature spine, there is no study concerning the impact of addition of crosslink to pedicle-screw-based instrumentation on the development of the spinal canal in young children. This study aims to determine the influence of the screw-rod-crosslink complex on the development of the spinal canal. This study reviewed 34 patients with congenital scoliosis (14 boys and 20 girls) who were treated with posterior-only hemivertebrectomy and pedicle-screw-based short-segment instrumentation before the age of 5 years. The mean age at surgery in this cohort was 37 ± 11 months (range 21-57 months). They were followed up for at least 24 months. Of these patients, 10 underwent only pedicle screw instrumentation without crosslink, and 24 with additional crosslink placement. The vertebrae were divided into three regions as follows: (1) S-CL (screw-crosslink) region, in which the vertebrae were inserted with bilateral pedicle screws and two rods connected with the crosslink; (2) S (screw) region, in which the vertebrae were inserted with bilateral pedicle screws but without crosslink; (3) NS (no screws) region, which comprised vertebrae cephalad or caudal to the instrumented region. The area, anteroposterior and transverse diameters of the spinal canal were measured at all vertebrae on the postoperative and last follow-up computed tomography axial images. The instrumentation-related parameters were also measured, including the distance between the bilateral screws and the screw base angles. The changes in the above measurements were compared between each region to evaluate the instrumentation's effect on the spinal canal growth. The mean follow-up was 37 ± 13 months (range 24-68 months) and the mean age at the last follow-up was 74 ± 20 months (range 46-119 months). In each region, the spinal canal dimensions significantly increased during the follow-up period. There was no significant difference in the spinal canal growth rate between the S and NS regions or between the S-CL and NS regions. Besides, a comparison of the S-CL and S regions regarding the changes in the measurements of the instrumentation construct revealed no significant differences. Pedicle-screw-based instrumentation does not cause retardation of the development of the spinal canal in young children. Moreover, use of the crosslink added to the screw-rod instrumentation also demonstrates no negative effect on the growth of the spinal canal. Thus, the addition of the crosslink to short screw-based instrumentation is recommended as an alternative to increase fixation stability in growing patients, even in very young pediatric population.
Preservation of lower extremity amputation length using muscle perforator free flaps.
Hallock, G G
2008-06-01
Coverage of any lower extremity amputation stump must be durable to resist external forces, well contoured, and thin enough for proper shoewear or prothesis fitting. Preservation of bone length to maximise the ability to ambulate is also of paramount importance. If local soft tissues are inadequate to fulfil these prerequisites, consideration of a microsurgical tissue transfer is a reasonable option, especially to cover bone or save a major joint. Muscle perforator free flaps, as shown in this series of eight patients using four different donor sites, are a versatile alternative for the necessary soft tissue augmentation. Multiple choices are available and often even from the involved lower extremity to minimise further morbidity. The vascular pedicles of this genré of flaps are relatively exceedingly long and of respectable calibre to facilitate reaching an appropriate recipient site. They can be sensate if desired. Of course, muscle function is by definition preserved. Complications are minimal and usually related to the reason for the amputation in the first place.
Ranjbari, Ardeshir; Gholami, Gholam Ali; Amid, Reza; Kadkhodazadeh, Mahdi; Youssefi, Navid; Mehdizadeh, Amir Reza; Aghaloo, Maryam
2016-01-01
Statement of the Problem Gingival recession has been considered as the most challenging issue in the field of periodontal plastic surgery. Purpose The purpose of this study was to evaluate the clinical efficacy of root coverage procedures by using partial thickness double pedicle graft and compare it with full thickness double pedicle graft. Materials and Method Eight patients, aged 15 to 58 years including 6 females and 2 males with 20 paired (mirror image) defects with class I and II gingival recession were randomly assigned into two groups. Clinical parameters such as recession depth, recession width, clinical attachment level, probing depth, and width of keratinized tissue were measured at the baseline and 6 months post-surgery. A mucosal double papillary flap was elevated and the respective root was thoroughly planed. The connective tissue graft was harvested from the palate, and then adapted over the root. The pedicle flap was secured over the connective tissue graft and sutured. The surgical technique was similar in the control group except for the prepared double pedicle graft which was full thickness. Results The mean root coverage was 88.14% (2.83 mm) in the test group and 85.7% (2.75 mm) in the control group. No statistical differences were found in the mean reduction of vertical recession, width of recession, or probing depth between the test and control groups. In both procedures, the width of keratinized tissue increased after three months and the difference between the two groups was not statistically significant in this respect. Conclusion Connective tissue with partial and full thickness double pedicle grafts can be successfully used for treatment of marginal gingival recession. PMID:27602394
Padiolleau, G; Marchand, J B; Odri, G A; Hamel, A; Gouin, F
2014-04-01
Scapulo-humeral arthrodesis (SHA) is a proven reconstruction method in patients with proximal humerus malignancies requiring resection of the shoulder abduction apparatus (rotator cuff and deltoid muscles) or its nerve supply. Standard practice consists in using a pedicled fibular flap. We use instead a pedicled autologous bone graft harvested from the ipsilateral scapular pillar. The objective of this study was to assess functional outcomes and radiological healing after SHA using a pedicled scapular pillar graft. We retrospectively reviewed the charts of the 12 patients managed at a single center by a single surgeon between 1994 and 2011. SHA was performed using a vascularised ipsilateral scapular pillar graft after proximal humerus resection to treat a bone malignancy. The graft was harvested from the ipsilateral scapular pillar, pedicled on the circumflex scapular artery, fitted into the remaining proximal humerus, and secured to the glenoid using screws. A humerus-scapular spine plate was added to stabilize the arthrodesis. Radiographic results were assessed on standard radiographs obtained at last follow-up. Functional outcomes were evaluated using the MusculoSkeletalTumour Society (MSTS) score and Toronto Extremity Salvage Score (TESS). After a mean follow-up of 4.9 years, 87.5% of SHA junctions were healed, mean MSTS score was 71%, and mean TESS score was 70%. The outcomes in our patients were similar to those reported after SHA using a pedicled fibular flap. However, our technique does not require microsurgery. It is simple, reproducible, and effective. Its indications of choice are intra- or extra-articular resection of the proximal humerus including the attachments of the rotator cuff and deltoid muscle tendons or the nerves supplying these muscles. Level IV (retrospective study). Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Lin, Tao; Li, Tangbo; Jiang, Heng; Ma, Jun; Zhou, Xuhui
2018-03-01
To compare effects of uniplanar and multiaxial pedicle screws on apical vertebral derotation efficiency in patients with Lenke V adolescent idiopathic scoliosis. For this retrospective study, patients with Lenke V adolescent idiopathic scoliosis with uniplanar pedicle screws (group I) and multiaxial pedicle screws (group II) were collected from January 2013 to December 2015. Grade of apical vertebral rotation was evaluated before and after surgery using the Nash-Moe and Upasani methods, respectively. The Scoliosis Research Society-22 scale was also used to evaluate patient satisfaction. There were no significant differences in terms of age, duration of follow-up, correction ratio, and preoperative level of apical rotation between groups (P < 0.05). Group I showed better apical vertebral derotation than group II (level 0, 10.5% vs. 2.3%; level I, 71.1% vs. 38.6%; level II, 18.4% vs. 59.1%; P = 0.001). The progression group showed lower bone maturity (odds ratio 52.0; 95% confidence interval, 6.3-430.7; P < 0.0001) in group I, and similar results were observed in group II (OR 12.3; 95% confidence interval, 1.3-121.3; P = 0.057). Patients in group I showed better satisfaction than patients in group II based on Scoliosis Research Society-22 scores (P < 0.05). Both types of pedicle screws could provide effective correction, but the uniplanar pedicle screw was better for derotation of vertebrae and provided patients with better satisfaction. Skeleton immaturity was positively correlated with progression of vertebral rotation after surgery. Copyright © 2017 Elsevier Inc. All rights reserved.
Allograft for maxillary sinus floor augmentation: a retrospective study of 90 cases.
Guerrero, Jaime S; Al-Jandan, Badr A
2012-04-01
The aim of this study is to demonstrate the clinical applicability and efficacy of an allograft for maxillary sinus augmentations in patients requiring placement of dental implants. Sixty consecutive patients underwent a total of 90 sinus augmentations. Twenty-nine were women and 31 men, with a mean age of 54 years. Twenty-six patients received a bilateral procedure and 34 unilateral. All cases were treated with the lateral wall technique. Allograft consisted of demineralized freeze-dried blocks in 6 cases, particulate in 82 cases, and a combination of both in 2 cases. In 30 patients, it was combined with platelet-rich plasma. A total of 84 implants were inserted. Bone samples of grafted areas were obtained in two patients for histological examination. Seventy-three implants were clinically successful at the reentry time. Eleven implants in seven patients were removed between 15 days and 6 months after their placement. Seven of these implants were replaced and received prostheses as well, for an overall postloading success rate of 95.2%. Follow-up for all patients after final restoration was between 12 and 96 months. Specimen's histological evaluation revealed bone formation and evidence of inflammatory infiltrate. Based on the findings of this study, it can be suggested that the use of the demineralized freeze-dried bone allograft from the Banco de Huesos y Tejidos Fundación Cosme y Damian for sinus augmentation is effective and constitutes a feasible therapeutic alternative for implant placement.
Lateral parabrachial nucleus mediates shortening of expiration during hypoxia.
Song, Gang; Poon, Chi-Sang
2009-01-01
Acute hypoxia elicits complex time-dependent responses including rapid augmentation of inspiratory drive, shortening of inspiratory and expiratory durations (T(I), T(E)), and short-term potentiation and depression. The central pathways mediating these varied effects are largely unknown. Here, we show that the lateral parabrachial nucleus (LPBN) of the dorsolateral pons specifically mediates T(E)-shortening during hypoxia and not other hypoxic response components. Twelve urethane-anesthetized and vagotomized adult Sprague-Dawley rats were exposed to 1-min poikilocapnic hypoxia before and after unilateral kainic acid or bilateral electrolytic lesioning of the LPBN. Bilateral lesions resulted in a significant increase in baseline T(E) under hyperoxia. After unilateral or bilateral lesions, the decrease in T(E) during hypoxia was markedly attenuated without appreciable changes in all other hypoxic response components. These findings add to the mounting evidence that the central processing of peripheral chemoafferent inputs is segregated into parallel integrator and differentiator (low-pass and high-pass filter) pathways that separately modulate inspiratory drive, T(I), T(E) and resultant short-term potentiation and depression.
Joint kinematics of surgeons during lumbar pedicle screw placement.
Park, Jeong-Yoon; Kim, Kyung-Hyun; Kuh, Sung-Uk; Chin, Dong-Kyu; Kim, Keun-Su; Cho, Yong-Eun
2016-12-01
A surgical robot for spine surgery has recently been developed. The objective is to assess the joint kinematics of the surgeon during spine surgery. We enrolled 18 spine surgeons, who each performed pedicle screw placement, and used an optoelectronic motion analysis system. Using three-dimensional (3D) motion images, distance changes in five joints and angle changes in six joints were calculated during surgery. Distance fluctuations increased gradually from the proximal to the distal joint. Angle fluctuations were largest at the distal point but did not gradually increase, and the elbow showed the second largest fluctuation. Changes along the X axis were larger than those of the Y and Z axes. The distances gradually increased from proximal portions of the body to the hand. In angle changes, the elbow was most dynamic during pedicle screw placement. The surgeons' whole joints carry out a harmonic role during lumbar pedicle screw placement. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
Carey, Joseph N; Sheckter, Clifford C; Watt, Andrew J; Lee, Gordon K
2013-08-01
Despite advances in nutritional supplementation, sepsis management, percutaneous drainage and surgical technique, enterocutaneous fistulae remain a considerable source of morbidity and mortality. Use of adjunctive modalities including negative pressure wound therapy and fibrin glue have been shown to improve the rapidity of fistula closure; however, the overall rate of closure remains poor. The challenge of managing chronic, high-output proximal enterocutaneous fistulae can be successfully achieved with appropriate medical management and intra-abdominal placement of pedicled rectus abdominis muscle flaps. We report two cases of recalcitrant high output enterocutaneous fistulae that were treated successfully with pedicled intra-abdominal rectus muscle flaps. Indications for pedicled intra-abdominal rectus muscle flaps include persistent patency despite a reasonable trial of non-operative intervention, failure of traditional operative interventions (serosal patch, Graham patch), and persistent electrolyte and nutritional abnormalities in the setting of a high-output fistula. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Kang, Stephen Y; Spector, Matthew E; Chepeha, Douglas B
2017-11-01
To demonstrate three reconstructive advantages of the perforator based rectus free tissue transfer: long pedicle, customizable adipose tissue, and volume reconstruction without muscle atrophy within a contained space. Thirty patients with defects of the head and neck were reconstructed with the perforator based rectus free tissue transfer. Transplant success was 93%. Mean pedicle length was 13.4cm. Eleven patients (37%) had vessel-poor necks and the long pedicle provided by this transplant avoided the need for vein grafts in these patients. Adipose tissue was molded in 17 patients (57%). Twenty-five patients (83%) had defects within a contained space, such as the orbit, where it was critical to have a transplant that avoided muscle atrophy. The perforator based rectus free tissue transfer provides a long pedicle, moldable fat for flap customization, and is useful in reconstruction of defects within a contained space where volume loss due to muscle atrophy is prevented. Copyright © 2017 Elsevier Ltd. All rights reserved.
A novel 3D guidance system using augmented reality for percutaneous vertebroplasty: technical note.
Abe, Yuichiro; Sato, Shigenobu; Kato, Koji; Hyakumachi, Takahiko; Yanagibashi, Yasushi; Ito, Manabu; Abumi, Kuniyoshi
2013-10-01
Augmented reality (AR) is an imaging technology by which virtual objects are overlaid onto images of real objects captured in real time by a tracking camera. This study aimed to introduce a novel AR guidance system called virtual protractor with augmented reality (VIPAR) to visualize a needle trajectory in 3D space during percutaneous vertebroplasty (PVP). The AR system used for this study comprised a head-mount display (HMD) with a tracking camera and a marker sheet. An augmented scene was created by overlaying the preoperatively generated needle trajectory path onto a marker detected on the patient using AR software, thereby providing the surgeon with augmented views in real time through the HMD. The accuracy of the system was evaluated by using a computer-generated simulation model in a spine phantom and also evaluated clinically in 5 patients. In the 40 spine phantom trials, the error of the insertion angle (EIA), defined as the difference between the attempted angle and the insertion angle, was evaluated using 3D CT scanning. Computed tomography analysis of the 40 spine phantom trials showed that the EIA in the axial plane significantly improved when VIPAR was used compared with when it was not used (0.96° ± 0.61° vs 4.34° ± 2.36°, respectively). The same held true for EIA in the sagittal plane (0.61° ± 0.70° vs 2.55° ± 1.93°, respectively). In the clinical evaluation of the AR system, 5 patients with osteoporotic vertebral fractures underwent VIPAR-guided PVP from October 2011 to May 2012. The postoperative EIA was evaluated using CT. The clinical results of the 5 patients showed that the EIA in all 10 needle insertions was 2.09° ± 1.3° in the axial plane and 1.98° ± 1.8° in the sagittal plane. There was no pedicle breach or leakage of polymethylmethacrylate. VIPAR was successfully used to assist in needle insertion during PVP by providing the surgeon with an ideal insertion point and needle trajectory through the HMD. The findings indicate that AR guidance technology can become a useful assistive device during spine surgeries requiring percutaneous procedures.
Kocman, A Emre; Kose, Aydan A; Karabagli, Yakup; Baycu, Cengiz; Cetin, Cengiz
2008-01-01
Composite flaps including soft tissues with bone or cartilage are widely used in reconstruction of three-dimensional defects, but have some disadvantages. Flap prefabrication with alloplastic implants is an alternative procedure. Axial pattern vascularised high density porous polyethylene (HDPP) implants are capable of sustaining skin grafts. The purpose of this study was to examine the vascularisation pattern of the skin island in a composite flap prefabrication model prepared with vascularised HDPP implants. Forty male Wistar rats divided into four groups were used. A 9.5 x 6 x 2 mm HDPP block was centered on the dissected saphenous pedicle and anchored under the abdominal skin in the experimental group I (n=10). In experimental group II (n=10) saphenous artery and vein were put between the skin and the implant. Thus, the structures were laid as skin, HDPP block, pedicle in experimental group I and skin, pedicle, HDPP block in experimental group II. HDPP block-implanted and pedicle-implanted only groups served as control groups I and II, respectively. Eight weeks after prefabrication, skin islands 1.5 x 5 cm in size incorporated with implants were elevated based on saphenous vessels in the experimental groups and skin islands only based on the pedicle in control group II. Skin islands of the same dimensions were raised as grafts in control group I. Nylon sheets were put under the flaps and grafts to prevent vascularisation from the recipient bed. Flap viability was assessed by measuring the surface area on the 7th day. Total necrosis developed in composite grafts of control group I. Flap survival was higher in experimental group II and control group II (45% and 46.8%) than in group I (29.28%). Histologic studies demonstrated fibrovascular ingrowth into the HDPP implants, except in control group I, with significant inflammatory response and necrosis. Vascularisation of skin and implants from the pedicle was seen also microangiographically. In conclusion, a composite flap prefabrication model including vascularised HDPP implant, skin and vascular carrier was developed. This new flap was termed a 'medporocutaneous flap'.
Bekara, Farid; Herlin, Christian; Somda, Serge; de Runz, Antoine; Grolleau, Jean Louis; Chaput, Benoit
2018-01-01
Currently, increasingly reconstructive surgeon consider the failure rates of perforator propeller flaps especially in the distal third of the lower leg are too important and prefer to return to the use of free flap at first line option with failure rates frequently lower than 5%. So, we performed a systematic review with meta-analysis comparing free flaps (perforator-based or not) and pedicled-propeller flaps to respond to the question "what is the safest coverage for distal third of the lower limb?" This review was conducted according to PRISMA criteria. From 1991 to 2015, MEDLINE®, Pubmed central, Embase and Cochrane Library were searched. The pooled estimations were performed by meta-analysis. The homogeneity Q statistic and the I 2 index were computed. We included 36 articles for free flaps (1,226 flaps) and 19 articles for pedicled-propeller flaps (302 flaps). The overall failure rate was 3.9% [95%CI:2.6-5.3] for free flaps and 2.77% [95%CI:0.0-5.6] for pedicled-propeller flaps (P = 0.36). The complication rates were 19.0% for free flaps and 21.4% for pedicled-propeller flaps (P = 0.37). In more detail, we noted for free flaps versus pedicled-propeller flaps: partial necrosis (2.70 vs. 6.88%, P = 0.001%), wound dehiscence (2.38 vs. 0.26%, P = 0.018), infection (4.45 vs. 1.22%, P = 0.009). The coverage failure rate was 5.24% [95%CI:3.68-6.81] versus 2.99% [95%CI:0.38-5.60] without significant difference (P = 0.016). In the lower limb the complications are not rare and many teams consider the free flaps to be safer. In this meta-analysis we provide evidence that failure and overall complications rate of perforator propeller flaps are comparable with free flaps. Although, partial necrosis is significantly higher for pedicled-propeller flaps than free flaps, in reality the success of coverage appears similar. © 2016 Wiley Periodicals, Inc. Microsurgery, 38:109-119, 2018. © 2016 Wiley Periodicals, Inc.
Liu, Tie; Hai, Yong
2014-07-01
To compare sagittal profiles of selective posterior thoracic instrumentation with segmental pedicle screws instrumentation and hybrid (hook and pedicle screw). Nowadays, thoracic screws are considered more effective than other constructs in spinal deformity correction and have become the treatment in adolescent idiopathic scoliosis surgery. However, recent research found that this enhanced correction ability may sacrifice sagittal balance. As lumbar lordosis is dependent upon thoracic kyphosis (TK), it has been important to maintain TK magnitude in selective thoracic fusions to keep balance. There is no sagittal measurement analysis between the hybrid and all-screw constructs type in cases of selective thoracic fusion. All adolescent idiopathic scoliosis (Lenke1) patients surgically treated in our department between 2003 and 2008 were reviewed. Radiographs of these patients, whose preoperative, immediately postoperative, and minimum 2-year follow-up after selective thoracic fusion (lower instrumented vertebrae not lower than L1, hybrid group the pedicle screw instrumentation not higher than T10) were evaluated, 21 patients underwent posterior hybrid instrumentation and 21 underwent pedicle screw instrumentation. No significant difference in sagittal profiles was observed between the 2 groups. At final follow-up, the proximal junctional measurement has a minor increase in both the groups. TK (T5-T12) also increased (+2.0 degrees of increase in hybrid group vs. +3.9 degrees of increase in the pedicle screw group). The effect of different instrumentation in changing TK at various time points between 2 groups was statistic different (P=0.004). Lumbar lordosis (L1-L5) was increased in both the groups. No significant changes in distal junctional measurement and thoracolumbar junction were noted. The C7 sagittal plumbline remained negative in both the groups at the final follow-up. There was no statistically significant difference comparing the sagittal alignment parameter of pedicle screw and hybrid constructs except for selective TK correction have differences. If used properly, both kinds of instrumentation could result in acceptable sagittal profiles when selective thoracic fusions were performed.
Fretting corrosion behavior of nitinol spinal rods in conjunction with titanium pedicle screws.
Lukina, Elena; Kollerov, Mikhail; Meswania, Jay; Khon, Alla; Panin, Pavel; Blunn, Gordon W
2017-03-01
Untypical corrosion damage including erosions combined with the build-up of titanium oxide as a corrosion product on the surface of explanted Nitinol spinal rods in the areas where it was in contact with titanium pedicle screw head is reported. It was suggested that Nitinol rods might have inferior fretting corrosion resistance compared with that made of titanium or CoCr. Fretting corrosion of Nitinol spinal rods with titanium (Ti6Al4V) pedicle screws were tested in-vitro by conducting a series of potentiostatic measurements of the peak-to-peak values of fretting corrosion current under bending in a 10% solution of calf serum in PBS. The test included Nitinol rods locked in titanium pedicle screws of different designs. Performance of commercially available titanium (Ti6Al4V) and CoCr spinal rods was also investigated for a comparison. Corrosion damage observed after the in-vitro tests was studied using SEM and EDAX analysis and was compared with patterns on Nitinol rods retrieved 12months after initial surgery. Metal ions level was measured in the test media after in-vitro experiments and in the blood and tissues of the patients who had the rods explanted. The results of this study revealed that Nitinol spinal rods locked in Ti pedicle screws are susceptible to fretting corrosion demonstrating higher fretting corrosion current compared with commercially used Ti6Al4V and CoCr rods. On the surface of Nitinol rods after in-vitro tests and on those retrieved from the patients similar corrosion patterns were observed. Improved resistance to fretting corrosion was observed with Nitinol rods in the in-vitro tests where pedicle screws were used with a stiffer locking mechanism. Since the development of the localized corrosion damage might increase the risk of premature fatigue failure of the rods and result in leaching of Ni ions, it is concluded that Nitinol rods should not be used in conjunction with Ti pedicle screws without special protection especially where the design provides a high degree of mobility to the rods. Copyright © 2016 Elsevier B.V. All rights reserved.
Brink, Rob C; Schlösser, Tom P C; Colo, Dino; Vincken, Koen L; van Stralen, Marijn; Hui, Steve C N; Chu, Winnie C W; Cheng, Jack C Y; Castelein, René M
2017-01-01
Cross-sectional. To quantify the asymmetry of the vertebral bodies and pedicles in the true transverse plane in adolescent idiopathic scoliosis (AIS) and to compare this with normal anatomy. There is an ongoing debate about the existence and magnitude of the vertebral body and pedicle asymmetry in AIS and whether this is an expression of a primary growth disturbance, or secondary to asymmetrical loading. Vertebral body asymmetry, defined as left-right overlap of the vertebral endplates (ie, 100%: perfect symmetry, 0%: complete asymmetry) was evaluated in the true transverse plane on CT scans of 77 AIS patients and 32 non-scoliotic controls. Additionally, the pedicle width, length, and angle and the length of the ideal screw trajectory were calculated. Scoliotic vertebrae were on average more asymmetric than controls (thoracic: AIS 96.0% vs. controls 96.4%; p = .005, lumbar: 95.8% vs. 97.2%; p < .001) and more pronounced around the thoracic apex (95.8%) than at the end vertebrae (96.3%; p = .031). In the thoracic apex; the concave pedicle was thinner (4.5 vs. 5.4 mm; p < .001) and longer (20.9 vs. 17.9 mm; p < .001), the length of the ideal screw trajectory was longer (43.0 vs. 37.3 mm; p < .001), and the transverse pedicle angle was greater (12.3° vs. 5.7°; p < .001) than the convex one. The axial rotation showed no clear correlation with the asymmetry. Even in non-scoliotic controls is a degree of vertebral body and pedicle asymmetry, but scoliotic vertebrae showed slightly more asymmetry, mostly around the thoracic apex. In contrast to the existing literature, there is no major asymmetry in the true transverse plane in AIS and no uniform relation between the axial rotation and vertebral asymmetry could be observed in these moderate to severe patients, suggesting that asymmetrical vertebral growth does not initiate rotation, but rather follows it as a secondary phenomenon. Level 4. Copyright © 2016 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.
Mouraux, Dominique; Brassinne, Eric; Sobczak, Stéphane; Nonclercq, Antoine; Warzée, Nadine; Sizer, Phillip S; Tuna, Turgay; Penelle, Benoît
2017-07-01
Objective: We assessed whether or not pain relief could be achieved with a new system that combines 3D augmented reality system (3DARS) and the principles of mirror visual feedback. Methods: Twenty-two patients between 18 and 75 years of age who suffered of chronic neuropathic pain. Each patient performed five 3DARS sessions treatment of 20 mins spread over a period of one week. The following pain parameters were assessed: (1) visual analogic scale after each treatment session (2) McGill pain scale and DN4 questionnaire were completed before the first session and 24 h after the last session. Results: The mean improvement of VAS per session was 29% ( p < 0.001). There was an immediate session effect demonstrating a systematic improvement in pain between the beginning and the end of each session. We noted that this pain reduction was partially preserved until the next session. If we compare the pain level at baseline and 24 h after the last session, there was a significant decrease ( p < 0.001) of pain of 37%. There was a significant decrease ( p < 0.001) on the McGill Pain Questionnaire and DN4 questionnaire ( p < 0.01). Conclusion: Our results indicate that 3DARS induced a significant pain decrease for patients who presented chronic neuropathic pain in a unilateral upper extremity. While further research is necessary before definitive conclusions can be drawn, clinicians could implement the approach as a preparatory adjunct for providing temporary pain relief aimed at enhancing chronic pain patients' tolerance of manual therapy and exercise intervention. Level of Evidence: 4.
Mordenfeld, Arne; Albrektsson, Tomas; Hallman, Mats
2014-06-01
There is a need for prospective, long-term follow-up studies of implants placed after maxillary sinus floor augmentation (MSFA). The aim of the present study was to determine whether deprotenized bovine bone (DPBB) used for MSFA may result in long-term stability of placed dental implants. Fourteen of the 20 patients included in the study were followed throughout the 10 years study period. These patients had 53 implants placed in 22 (6 unilateral and 8 bilateral) maxillary sinuses augmented with a mixture of 80% DPBB and 20% autogenous bone (80:20), and 15 implants placed in non-grafted sites. Clinical and radiographic examinations of the implants and grafts were performed. After 10 years of functional loading 15 of the initially placed 108 implants had been lost giving a cumulative survival rate of 86%. The mean marginal bone loss was 1.6 ± 1.0 mm. There were no statistically significant differences in marginal bone level, pocket depth, or ISQ-values between implants placed in residual or grafted bone or between smokers or non-smokers at 10 years follow-up. There was a statistically significant reduction (p < .01) in graft height between 3 months and 2 years but no further significant reduction up to 10 years. The first 2 years after placement of implants with turned surfaces placed in sites after sinus floor augmentation with DPBB and autogenous bone seem to be critical for implant survival. At 10 years follow-up, the remaining implants presented excellent clinical and radiological results regardless of smoking habits or implant sites (augmented or residual bone). © 2012 Wiley Periodicals, Inc.
Newcomb, Anna G. U. S.; Baek, Seungwon; Kelly, Brian P.; Crawford, Neil R.
2016-01-01
Angled screw insertion has been advocated to enhance fixation strength during posterior spine fixation. Stresses on a pedicle screw and surrounding vertebral bone with different screw angles were studied by finite element analysis during simulated multidirectional loading. Correlations between screw-specific vertebral geometric parameters and stresses were studied. Angulations in both the sagittal and axial planes affected stresses on the cortical and cancellous bones and the screw. Pedicle screws pointing laterally (vs. straight or medially) in the axial plane during superior screw angulation may be advantageous in terms of reducing the risk of both screw loosening and screw breakage. PMID:27454197
Malrotation of the McGhan Style 510 prosthesis.
Schots, Jeroen M P; Fechner, Maarten R; Hoogbergen, Maarten M; van Tits, Herm W H J
2010-07-01
Anatomically shaped cohesive silicone breast implants are frequently used in aesthetic and reconstructive surgery. After successful results with the Style 410 prosthesis, McGhan (Natrelle, Allergan) introduced the Style 510 prosthesis. After using this novel prosthesis, the authors encountered a high number of prosthesis malrotations on self-reported follow-up. Therefore, a retrospective medical record review was performed to determine the prevalence of malrotation of the Style 510 prosthesis. From January of 2005 to December of 2006, 73 (146 prostheses) aesthetic augmentation mammaplasty procedures were performed using Style 510 prostheses. All prostheses were placed subglandularly through an inframammary incision. The postsurgical protocol for the first 3 weeks involved wearing a nonwired compression bra, abstinence from sports activities, and abstinence from heavy labor. Standard follow-up was at 1 week, 3 months, and if necessary. On self-reported follow-up, 8.2 percent of all prostheses were rotated. These rotations all occurred unilaterally after a mean period of 10 months (range, 3 to 19 months). No relation to an inciting incident or prosthesis volume could be found. The number of rotations of the Style 510 prosthesis seen after primary aesthetic breast augmentation is high. An obvious cause of this major problem has not been found. This led the authors to discontinue using the Style 510 prosthesis for primary aesthetic mammary augmentations in their practice.
Changes in blood velocity following microvascular free tissue transfer.
Hanasono, Matthew M; Ogunleye, Olubunmi; Yang, Justin S; Hartley, Craig J; Miller, Michael J
2009-09-01
Understanding how pedicle blood velocities change after free tissue transfer may enable microvascular surgeons to predict when thrombosis is most likely to occur. A 20-MHz Doppler probe was used to measure arterial and venous blood velocities prior to pedicle division and 20 minutes after anastomosis in 32 microvascular free flaps. An implantable Doppler probe was then used to measure arterial and venous blood velocities daily for 5 days. Peak arterial blood velocity averaged 30.6 cm/s prior to pedicle division and increased to 36.5 cm/s 20 minutes after anastomosis ( P < 0.05). Peak venous blood velocity averaged 7.6 cm/s prior to pedicle division and increased to 12.4 cm/s 20 minutes after anastomosis ( P < 0.05). Peak arterial blood velocities averaged 34.0, 37.7, 43.8, 37.9, 37.6 cm/s on postoperative days (PODs) 1 through 5, respectively. Peak venous blood velocities averaged 11.9, 14.5, 18.2, 16.8, 17.7 cm/s on PODs 1 through 5, respectively. The peak arterial blood velocity on POD 3, and peak venous blood velocities on PODs 2, 3, and 5 were significantly higher than 20 minutes after anastomosis ( P < 0.05). Arterial and venous blood velocities increase for the first 3 postoperative days, potentially contributing to the declining risk for pedicle thrombosis during this time period.
Case report: absent C6 cervical pedicle in a collegiate football player.
Fowler, John R; Moyer, Ray A
2010-06-01
Congenital absence of a cervical pedicle is a rare clinical finding with only 70 reported cases in the literature from 1946 until present. The congenitally absent pedicle has clinical importance owing to the frequency of misdiagnosis and inappropriate invasive treatments. We present the case of a 21-year-old college football player who experienced neck and shoulder pain after violent twisting of his neck by the face mask. The player walked off the field under his own power. He was sent to the locker room, where he underwent right shoulder and cervical spine radiographs. Initial review of the radiographs raised concern for a jumped right C6 facet. The patient then underwent CT and MRI of the cervical spine, confirming the diagnosis of an absent cervical pedicle. He was treated nonoperatively for a short time and completed the season. He had no symptoms at last followup at 8 months. The most frequent location of the absent cervical pedicle is at the C6 level, and the next most common is at the C5 level. Neural compression or instability is uncommon and nonsurgical treatment is the mainstay of treatment. Misdiagnosis can lead to inappropriate treatment such as halo or tong application with traction, which occurred in seven of 57 cases in one series, and exploratory surgery, which occurred in four of 57 cases.
Boucher, F; Pinatel, B; Shipkov, H; Mertens, P; Rouviere, O; Braye, F; Mojallal, A
2014-10-01
The latissimus dorsi muscle flap is a type V according to Mathes and Nahai. It is vascularized by a proximal main pedicle represented by the thoraco-dorsal pedicle and pedicle distal accessory represented by the dorsal branches of the posterior intercostal arteries. The main thoraco-dorsal pedicle has a descending branch and a transverse branch. This anatomical study clarifies the muscular territory vascularized by the transverse branch of thoraco-dorsal artery for a secondary use after harvesting a thoraco-dorsal artery perforator flap or a muscle-sparing latissimus dorsi flap. Our study focused on ten dissections latissimus dorsi muscle taken from five fresh cadavers chest, carried out within the University Department of Anatomy. The descending branch of thoraco-dorsal artery was ligated, the transverse branch was cannulated and injected with a mixture of barium sulfate/gelatin. After freezing, a static angiotomodensitometry (3D) of each flap was performed. The average muscular surface vascularized by the transverse branch is measured at 80% (77% minimum value, maximum value 83%) of the complete latissimus dorsi muscle. Intermuscular connections between the two branches of thoraco-dorsal pedicle were shown. The use of a ipsilateral latissimus dorsi muscle is a therapeutic option after harvesting a thoraco-dorsal artery perforator flap (TAP) or a muscle-sparing latissimus dorsi flap (MSLD-flap). Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Caballero, Alberto; Barrios, Carlos; Burgos, Jesús; Hevia, Eduardo; Correa, Carlos
2011-08-01
This experimental study in pigs was aimed at evaluating spinal growth disorders after partial arrest of the vertebral epiphyseal plates (EP) and neurocentral cartilages (NCC). Unilateral and multisegmental single or combined lesions of the physeal structures were performed by electrocoagulation throughout a video-assisted thoracoscopical approach. Thirty 4-week-old domestic pigs (mean weight 16 kg) were included in the experiments. The superior and inferior epiphyseal plates of T5 to T9 vertebra were damaged in ten animals by hemicircumferential electrocoagulation (group I). In other ten pigs (group II), right NCC at the same T5-T9 levels were damaged. Ten other animals underwent combined lesions of the ipsilateral hemiepiphyseal plates and NCC at the T5-T9 levels. A total of 26 animals could be evaluated after 12 weeks of follow-up using conventional X-rays, CT scans and histology. The pigs with hemicircumferential EP damage developed very slight concave non-structured scoliotic deformities without vertebral rotation.(mean 12° Cobb; range10-16°). Some of the damaged vertebra showed a marked wedgening with unilateral development alteration of the vertebral body, including the adjacent discs The animals with damage of the NCC developed mild scoliotic curves (mean 19° Cobb; range 16-24°) with convexity opposite to the damaged side and loss of physiological kyphosis. The injured segments showed an asymmetric growth with hypoplasia of the pedicle and costovertebral joints at the damaged side. The pigs undergoing combined EP and NCC lesions developed minimal non-structured curves, ranging from 10 to 12° Cobb. In these animals there was a lack of growth of a vertebral hemibody and disc hypoplasia at the damaged segments. Both damage of the NCC and the EP affect the height of the vertebral body. No spinal stenosis was found in any case. In most cases, the adjacent superior and inferior vertebral EP to damaged segments had a compensatory growth that maintained the straight spinal shape. In summary, unilateral direct lesion of the EP by hemicircumferential thoracoscopic electrocoagulation modifies vertebral growth, but is not able to induce true scoliostic curves in pigs. Only animals with damaged NCC developed mild scoliotic curves of lordotic type. This work rediscovers and emphasizes the decisive role of the neurocentral cartilage in the ethiopatogeny of idiopathic scoliosis.
Bernhardt, G; Awiszus, F; Meister, U; Heyde, C E; Böhm, H
2016-06-01
Transpedicular screw fixation of spinal segments has been described for a variety of surgical indications and is a key element in spinal surgery. The aim of transpedicular screw fixation is to achieve maximal stability. Screw malposition should be obviated to avoid neurological complications. There are published methods of applying evoked EMG to control screw position in relation to neural structures. These studies demonstrated that an intact bony pedicle wall acts as an electrical isolator between the screw and spinal nerve root. The aim of our study was to evaluate the impact of intraoperative pedicle screw monitoring on screw positioning. We enrolled 22 patients in this prospective randomised study, who underwent spinal instrumentation after being split into two equal groups. In the first group, dorsal instrumentation was supplemented with intraoperative nerve root monitoring using the INS-1-System (NuVasive, San Diego USA). In the second group, screws were inserted without additional pedicle monitoring. All patients underwent monosegmental instrumentation with "free hand implanted" pedicle screws. 44 screws were inserted in each group. The screw position was evaluated postoperatively using CT scans. The position of the screws in relation to the pedicle was measured in three different planes: sagittal, axial and coronal. The accuracy of the screw position was described using the Berlemann classification system. Screw position is classified in three groups: type 1 correct screw position, type 2 encroachment on the inner cortical wall, type 3 pedicle cortical perforation. Screw angulation and secondary operative criteria were also evaluated. The use of neuromonitoring did not influence the distance between the centre of the screws and the pedicle wall. Distances only depended on the implantation side (right and left) and the height of implantation (caudal or cranial screw). Because of the low number of cases, no conclusion could be reached about the influence of root monitoring on the correct positioning of the screws. There was at least a non-significant trend towards more frequent perforation of the pedicle in the monitor group. In the present study, we showed that root monitoring had a significant effect on the scattering of transversal angles. These were increased compared to the control group. Otherwise, the implantation angle was not shown to depend on the use of neuromonitoring. Neuromonitoring did not influence blood loss or operative time. The data did not permit any conclusion as to whether this technique can minimise the frequency of pedicle screw malposition. The four coronal plane distances did not depend on the use of neuromonitoring. The inclination angle was also unaffected by neuromonitoring. The only parameter for which we found any effect was the transverse angle. The mean values were similar in both groups, but the variances were not equal. The effect of monitoring on the only parameter which could not be evaluated by fluoroscopy is thus rather unfavourable. Georg Thieme Verlag KG Stuttgart · New York.
Percutaneous spinal fixation simulation with virtual reality and haptics.
Luciano, Cristian J; Banerjee, P Pat; Sorenson, Jeffery M; Foley, Kevin T; Ansari, Sameer A; Rizzi, Silvio; Germanwala, Anand V; Kranzler, Leonard; Chittiboina, Prashant; Roitberg, Ben Z
2013-01-01
In this study, we evaluated the use of a part-task simulator with 3-dimensional and haptic feedback as a training tool for percutaneous spinal needle placement. To evaluate the learning effectiveness in terms of entry point/target point accuracy of percutaneous spinal needle placement on a high-performance augmented-reality and haptic technology workstation with the ability to control the duration of computer-simulated fluoroscopic exposure, thereby simulating an actual situation. Sixty-three fellows and residents performed needle placement on the simulator. A virtual needle was percutaneously inserted into a virtual patient's thoracic spine derived from an actual patient computed tomography data set. Ten of 126 needle placement attempts by 63 participants ended in failure for a failure rate of 7.93%. From all 126 needle insertions, the average error (15.69 vs 13.91), average fluoroscopy exposure (4.6 vs 3.92), and average individual performance score (32.39 vs 30.71) improved from the first to the second attempt. Performance accuracy yielded P = .04 from a 2-sample t test in which the rejected null hypothesis assumes no improvement in performance accuracy from the first to second attempt in the test session. The experiments showed evidence (P = .04) of performance accuracy improvement from the first to the second percutaneous needle placement attempt. This result, combined with previous learning retention and/or face validity results of using the simulator for open thoracic pedicle screw placement and ventriculostomy catheter placement, supports the efficacy of augmented reality and haptics simulation as a learning tool.
Mumith, A; Coathup, M; Chimutengwende-Gordon, M; Aston, W; Briggs, T; Blunn, G
2017-02-01
Massive endoprostheses rely on extra-cortical bone bridging (ECBB) to enhance fixation. The aim of this study was to investigate the role of selective laser sintered (SLS) porous collars in augmenting the osseointegration of these prostheses. The two novel designs of porous SLS collars, one with small pores (Ø700 μm, SP) and one with large pores (Ø1500 μm, LP), were compared in an ovine tibial diaphyseal model. Osseointegration of these collars was compared with that of a clinically used solid, grooved design (G). At six months post-operatively, the ovine tibias were retrieved and underwent radiological and histological analysis. Porous collars provided a significantly greater surface (p < 0.001) for the ingrowth of bone than the standard grooved design. Significantly greater extracortical pedicle formation was seen radiologically around the grooved design (length p = 0.002, thickness p < 0.001, surface area p = 0.002) than around the porous collars. However, the ingrowth of bone occurred from the transection site into the porous structure of both types of collar. A fivefold increase in integration was seen with the SP and a threefold increase in the LP design when compared with G (p < 0.001). SLS porous collars allow the direct ingrowth of more bone and are better than current designs which rely on surface ongrowth and ECBB. Cite this article: Bone Joint J 2017;99-B:276-82. ©2017 The British Editorial Society of Bone & Joint Surgery.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-18
... regarding the classification of posterior cervical screws, including pedicle and lateral mass screws. Cervical pedicle and lateral mass screws are components of rigid, posterior spinal screw and rod systems... neck pain confirmed by radiographic studies), trauma, deformity, failed previous fusion, tumor...
Spatiotemporal regulation of ATP and Ca2+ dynamics in vertebrate rod and cone ribbon synapses
Johnson, Jerry E.; Perkins, Guy A.; Giddabasappa, Anand; Chaney, Shawntay; Xiao, Weimin; White, Andrew D.; Brown, Joshua M.; Waggoner, Jenna; Ellisman, Mark H.
2007-01-01
Purpose In conventional neurons, Ca2+ enters presynaptic terminals during an action potential and its increased local concentration triggers transient exocytosis. In contrast, vertebrate photoreceptors are nonspiking neurons that maintain sustained depolarization and neurotransmitter release from ribbon synapses in darkness and produce light-dependent graded hyperpolarizing responses. Rods transmit single photon responses with high fidelity, whereas cones are less sensitive and exhibit faster response kinetics. These differences are likely due to variations in presynaptic Ca2+ dynamics. Metabolic coupling and cross-talk between mitochondria, endoplasmic reticulum (ER), plasma membrane Ca2+ ATPase (PMCA), and Na+-Ca2+ exchanger (NCX) coordinately control presynaptic ATP production and Ca2+ dynamics. The goal of our structural and functional studies was to determine the spatiotemporal regulation of ATP and Ca2+ dynamics in rod spherules and cone pedicles. Methods Central retina tissue from C57BL/6 mice was used. Laser scanning confocal microscopy (LSCM) experiments were conducted on fixed-frozen vertical sections. Primary antibodies were selected for their tissue/cellular specificity and ability to recognize single, multiple or all splice variants of selected isoforms. Electron microscopy (EM) and 3-D electron tomography (ET) studies used our standard procedures on thin- and thick-sectioned retinas, respectively. Calibrated fluo-3-Ca2+ imaging experiments of dark- and light-adapted rod and cone terminals in retinal slices were conducted. Results Confocal microscopy showed that mitochondria, ER, PMCA, and NCX1 exhibited distinct retinal lamination patterns and differential distribution in photoreceptor synapses. Antibodies for three distinct mitochondrial compartments differentially labeled retinal areas with high metabolic demand: rod and cone inner segments, previously undescribed cone juxtanuclear mitochondria and the two plexiform layers. Rod spherule membranes uniformly and intensely stained for PMCA, whereas the larger cone pedicles preferentially stained for NCX1 at their active zones and PMCA near their mitochondria. EM and ET revealed that mitochondria in rod spherules and cone pedicles differed markedly in their number, location, size, volume, and total cristae surface area, and cristae junction diameter. Rod spherules had one large ovoid mitochondrion located near its active zone, whereas cone pedicles averaged five medium-sized mitochondria clustered far from their active zones. Most spherules had one ribbon synapse, whereas pedicles contained numerous ribbon synapses. Fluo-3 imaging studies revealed that during darkness rod spherules maintained a lower [Ca2+] than cone pedicles, whereas during light adaptation pedicles rapidly lowered their [Ca2+] below that observed in spherules. Conclusions These findings indicate that ATP demand and mitochondrial ATP production are greater in cone pedicles than rod spherules. Rod spherules employ high affinity/low turnover PMCA and their mitochondrion to maintain a relatively low [Ca2+] in darkness, which increases their sensitivity and signal-to-noise ratio. In contrast, cone pedicles utilize low affinity/high turnover NCX to rapidly lower their high [Ca2+] during light adaptation, which increases their response kinetics. Spatiotemporal fluo-3-Ca2+ imaging results support our immunocytochemical results. The clustering of cone pedicle mitochondria likely provides increased protection from Ca2+ overload and permeability transition. In summary, these novel studies reveal that several integrated cellular and subcellular components interact to regulate ATP and Ca2+ dynamics in rod and cone synaptic terminals. These results should provide a greater understanding of in vivo photoreceptor synaptic terminal exocytosis/endocytosis, Ca2+ overload and therapies for retinal degenerations. PMID:17653034
Spatiotemporal regulation of ATP and Ca2+ dynamics in vertebrate rod and cone ribbon synapses.
Johnson, Jerry E; Perkins, Guy A; Giddabasappa, Anand; Chaney, Shawntay; Xiao, Weimin; White, Andrew D; Brown, Joshua M; Waggoner, Jenna; Ellisman, Mark H; Fox, Donald A
2007-06-15
In conventional neurons, Ca2+ enters presynaptic terminals during an action potential and its increased local concentration triggers transient exocytosis. In contrast, vertebrate photoreceptors are nonspiking neurons that maintain sustained depolarization and neurotransmitter release from ribbon synapses in darkness and produce light-dependent graded hyperpolarizing responses. Rods transmit single photon responses with high fidelity, whereas cones are less sensitive and exhibit faster response kinetics. These differences are likely due to variations in presynaptic Ca2+ dynamics. Metabolic coupling and cross-talk between mitochondria, endoplasmic reticulum (ER), plasma membrane Ca2+ ATPase (PMCA), and Na+-Ca2+ exchanger (NCX) coordinately control presynaptic ATP production and Ca2+ dynamics. The goal of our structural and functional studies was to determine the spatiotemporal regulation of ATP and Ca2+ dynamics in rod spherules and cone pedicles. Central retina tissue from C57BL/6 mice was used. Laser scanning confocal microscopy (LSCM) experiments were conducted on fixed-frozen vertical sections. Primary antibodies were selected for their tissue/cellular specificity and ability to recognize single, multiple or all splice variants of selected isoforms. Electron microscopy (EM) and 3-D electron tomography (ET) studies used our standard procedures on thin- and thick-sectioned retinas, respectively. Calibrated fluo-3-Ca2+ imaging experiments of dark- and light-adapted rod and cone terminals in retinal slices were conducted. Confocal microscopy showed that mitochondria, ER, PMCA, and NCX1 exhibited distinct retinal lamination patterns and differential distribution in photoreceptor synapses. Antibodies for three distinct mitochondrial compartments differentially labeled retinal areas with high metabolic demand: rod and cone inner segments, previously undescribed cone juxtanuclear mitochondria and the two plexiform layers. Rod spherule membranes uniformly and intensely stained for PMCA, whereas the larger cone pedicles preferentially stained for NCX1 at their active zones and PMCA near their mitochondria. EM and ET revealed that mitochondria in rod spherules and cone pedicles differed markedly in their number, location, size, volume, and total cristae surface area, and cristae junction diameter. Rod spherules had one large ovoid mitochondrion located near its active zone, whereas cone pedicles averaged five medium-sized mitochondria clustered far from their active zones. Most spherules had one ribbon synapse, whereas pedicles contained numerous ribbon synapses. Fluo-3 imaging studies revealed that during darkness rod spherules maintained a lower [Ca2+] than cone pedicles, whereas during light adaptation pedicles rapidly lowered their [Ca2+] below that observed in spherules. These findings indicate that ATP demand and mitochondrial ATP production are greater in cone pedicles than rod spherules. Rod spherules employ high affinity/low turnover PMCA and their mitochondrion to maintain a relatively low [Ca2+] in darkness, which increases their sensitivity and signal-to-noise ratio. In contrast, cone pedicles utilize low affinity/high turnover NCX to rapidly lower their high [Ca2+] during light adaptation, which increases their response kinetics. Spatiotemporal fluo-3-Ca2+ imaging results support our immunocytochemical results. The clustering of cone pedicle mitochondria likely provides increased protection from Ca2+ overload and permeability transition. In summary, these novel studies reveal that several integrated cellular and subcellular components interact to regulate ATP and Ca2+ dynamics in rod and cone synaptic terminals. These results should provide a greater understanding of in vivo photoreceptor synaptic terminal exocytosis/endocytosis, Ca2+ overload and therapies for retinal degenerations.
Koch, Felix P; Becker, Jürgen; Terheyden, Hendrik; Capsius, Björn; Wagner, Wilfried
2010-11-01
The aim of this prospective, randomized clinical trial was to investigate the potential of recombinant human growth and differentiation factor-5 (rhGDF-5) coated onto β-tricalcium phosphate (β-TCP) (rhGDF-5/β-TCP) to support bone formation after sinus lift augmentation. In total, 31 patients participated in this multicenter clinical trial. They required a two-stage unilateral maxillary sinus floor augmentation (residual bone height <5 mm). According to a parallel-group design, the patients were randomized to three treatment groups: (a) augmentation with rhGDF-5/β-TCP and a 3-month healing period, (b) augmentation with rhGDF-5/β-TCP and a 4-month healing period and (c) medical device β-TCP mixed with autologous bone and a 4-month healing period. The primary study objective was the area of newly formed bone within the augmented area as assessed by histomorphometric evaluation of trephine bur biopsies. The osseous regeneration was similar in each treatment group; the amount of newly formed bone ranged between 28% (± 15.5%) and 31.8% (± 17.9%). Detailed analysis of histological data will be published elsewhere. As secondary efficacy variables, the augmentation height at the surgery site was measured by radiography. The largest augmentation was radiologically achieved in the rhGDF-5/β-TCP - 3-month and the rhGDF-5/β-TCP - 4-month treatment groups. As safety parameters, adverse events were recorded and anti-drug antibody levels were evaluated. Most of the adverse events were judged as unrelated to the study medication. Four out of 47 (8.5%) implants failed in patients treated with rhGDF-5/β-TCP, a result that is in agreement with the general implant failure rate of 5-15%. Transiently very low amounts of anti-rhGDF-5 antibodies were detected in some patients who received rhGDF-5, which was not related to the bone formation outcome. rhGDF-5/β-TCP was found to be effective and safe as the control treatment with autologous bone mixed β-TCP in sinus floor augmentation. Thus, further investigation regarding efficacy and safety will be carried out in larger patient populations. © 2010 John Wiley & Sons A/S.
Oberkircher, Ludwig; Krüger, Antonio; Hörth, Dominik; Hack, Juliana; Ruchholtz, Steffen; Fleege, Christoph; Rauschmann, Michael; Arabmotlagh, Mohammad
2018-03-01
In the operative treatment of osteoporotic vertebral body fractures, a dorsal stabilization in combination with a corpectomy of the fractured vertebral body might be necessary with respect to the fracture morphology, whereby the osteoporotic bone quality may possibly increase the risk of implant failure. To achieve better stability, it is recommended to use cement-augmented screws for dorsal instrumentation. Besides careful end plate preparation, cement augmentation of the adjacent end plates has also been reported to lead to less reduction loss. The aim of the study was to evaluate biomechanically under cyclic loading whether an additional cement augmentation of the adjacent end plates leads to improved stability of the inserted cage. Methodical cadaver study. Fourteen fresh frozen human thoracic spines with proven osteoporosis were used (T2-T7). After removal of the soft tissues, the spine was embedded in Technovit (Kulzer, Germany). Subsequently, a corpectomy of T5 was performed, leaving the dorsal ligamentary structures intact. After randomization with respect to bone quality, two groups were generated: Dorsal instrumentation (cemented pedicle screws, Medtronic, Minneapolis, MN, USA)+cage implantation (CAPRI Corpectomy Cage, K2M, Leesburg, VA, USA) without additional cementation of the adjacent endplates (Group A) and dorsal instrumentation+cage implantation with additional cement augmentation of the adjacent end plates (Group B). The subsequent axial and cyclic loading was performed at a frequency of 1 Hz, starting at 400 N and increasing the load within 200 N after every 500 cycles up to a maximum of 2,200 N. Load failure was determined when the cages sintered macroscopically into the end plates (implant failure) or when the maximum load was reached. One specimen in Group B could not be clamped appropriately into the test bench for axial loading because of a pronounced scoliotic misalignment and had to be excluded. The mean strength for implant failure was 1,000 N±258.2 N in Group A (no cement augmentation of the adjacent end plates, n=7); on average, 1,622.1±637.6 cycles were achieved. In Group B (cement augmentation of the adjacent end plates, n=6), the mean force at the end of loading was 1,766.7 N±320.4 N; an average of 3,572±920.6 cycles was achieved. Three specimens reached a load of 2,000 N. The differences between the two groups were significant (p=.006 and p=.0047) regarding load failure and number of cycles. Additional cement augmentation of the adjacent end plates during implantation of a vertebral body replacement in osteoporotic bone resulted in a significant increased stability of the cage in the axial cyclic loading test. Copyright © 2017 Elsevier Inc. All rights reserved.
D'Cunha, Craig; Plakiotis, Christos; O'Connor, Daniel W
2016-06-01
Electroconvulsive therapy (ECT) prescription rates rise with age, making it important that treatments be made as effective and safe as possible (Plakiotis et al., 2012). Older people are vulnerable to post-treatment confusion and to subsequent deficits in attention, new learning, and autobiographical memory (Gardner and O'Connor, 2008). Strategies to minimize cognitive side-effects include unilateral electrode placement and stimulus dose titration whereby electrical charge is individually calibrated to seizure threshold (Sackeim et al., 2000). It remains the case, however, that threshold levels typically rise over the treatment course, leading to an increase both in delivered charge and the risk of adverse sequelae.
Pedicled unipolar latissimus dorsi flap for reconstruction of finger extensor *
Takahashi, Mitsuhiko; Kasai, Tokio; Hibino, Naohito; Ishii, Seiji; Mitsuhashi, Tadashi
2017-01-01
Abstract We describe the use of a pedicled unipolar latissimus dorsi flap to restore finger extension. The patient had large defects in the radial nerve and extensor musculature. A long-tailed, 50-cm-long flap was prepared, which enabled the end of the flap to be sutured to the extensor digitorum. PMID:28470032
Reconstruction of trochanteric pressure sores with pedicled anterolateral thigh myocutaneous flaps.
Wang, Chih-Hsin; Chen, Shih-Yi; Fu, Ju-Peng; Dai, Niann-Tzyy; Chen, Shao-Liang; Chen, Tim-Mo; Chen, Shyi-Gen
2011-05-01
To provide an alternative choice for covering trochanteric pressure sores, we report on a modified pedicle anterolateral thigh (ALT) myocutaneous flap based on the descending branch of the lateral circumflex femoral artery. From August 2007 to January 2010, 20 consecutive patients (10 men and 10 women) underwent 21 pedicled ALT myocutaneous flaps for reconstruction of trochanteric pressure sores. The flap was designed and elevated, resembling the ALT perforator flap including part of the vastus lateralis muscle but without skeletonisation of the perforators. The mean age of patients was 79.4 years (range: 46-103). The mean follow-up period was 13.9 months (range: 3-32). The flaps were 8-21 cm long and 5-11 cm wide. All flaps healed without major complications. All donor sites were closed primarily without skin grafting and showed good aesthetic results. No recurrence was observed. This modified design of pedicled ALT myocutaneous flap without skeletonisation of perforators is a reliable and easily harvested flap for reconstruction of trochanteric pressure sores with limited morbidity. Crown Copyright © 2010. Published by Elsevier Ltd. All rights reserved.
Toft, Peter B
2016-01-01
To review and present the results of a one-step method employing a free tarsal plate graft and a myocutaneous pedicle flap plus a free skin graft for reconstruction of large upper eyelid defects after tumour surgery. This was a retrospective case-series of 8 patients who underwent reconstruction of the upper eyelid after tumour removal. The horizontal defect involved 50-75% of the lid (3 pts.), more than 75% (3 pts.), and more than 75% plus the lateral canthus (2 pts.). The posterior lamella was reconstructed with contralateral upper eyelid tarsal plate. The anterior lamella was reconstructed with a laterally based myocutaneous pedicle flap in 7 patients, leaving a raw surface under the brow which was covered with a free skin graft. In 1 patient with little skin left under the brow, the anterior lamella was reconstructed with a bi-pedicle orbicularis muscle flap together with a free skin graft. All patients healed without necrosis, did not suffer from lagophthalmos, achieved reasonable cosmesis, and did not need lubricants. In one patient, a contact lens was necessary for three weeks because of corneal erosion. One patient still needs a contact lens 3 months after excision to avoid eye discomfort. Large upper eyelid defects can be reconstructed with a free tarsal plate graft and a laterally based myocutaneous pedicle flap in combination with a free skin graft. Two-step procedures can probably be avoided in most cases.
Vertical reduction mammaplasty utilizing the superomedial pedicle: is it really for everyone?
Neaman, Keith C; Armstrong, Shannon D; Mendonca, Shawn J; Aitken, Marguerite A; VanderWoude, Douglas L; Renucci, John D; Alfonso, David R
2012-08-01
Classically, the vertical-style reduction mammaplasty utilizing a superomedial pedicle has been limited to smaller reductions secondary to concerns for poor wound healing and nipple necrosis. The authors reviewed a large cohort of patients who underwent a vertical-style superomedial pedicle reduction mammaplasty in an attempt to demonstrate its safety and efficacy in treating symptomatic macromastia. A retrospective review was performed of 290 patients (558 breasts) who underwent a vertical-style superomedial pedicle reduction mammaplasty. All procedures were conducted by one of 4 plastic surgeons over 6 years (JDR, MAA, DLV, DRA). The average resection weight was 551.7 g (range, 176-1827 g), with 4.6% of resections greater than 1000 g. A majority of patients (55.2%) concomitantly underwent liposuction of the breast. The total complication rate was 22.7%, with superficial dehiscence (8.8%) and hypertrophic scarring (8.8%) comprising the majority. Nipple sensory changes occurred in 1.6% of breasts, with no episodes of nipple necrosis. The revision rate was 2.2%. Patients with complications had significantly higher resection volumes and nipple-to-fold distances (P = .014 and .010, respectively). The vertical-style superomedial pedicle reduction mammaplasty is safe and effective for a wide range of symptomatic macromastia. The nipple-areola complex can be safely transposed, even in patients with larger degrees of macromastia, with no episodes of nipple necrosis. The adjunctive use of liposuction should be considered safe. Last, revision rates were low, correlating with a high level of patient satisfaction.
Stress analysis in a pedicle screw fixation system with flexible rods in the lumbar spine.
Kim, Kyungsoo; Park, Won Man; Kim, Yoon Hyuk; Lee, SuKyoung
2010-01-01
Breakage of screws has been one of the most common complications in spinal fixation systems. However, no studies have examined the breakage risk of pedicle screw fixation systems that use flexible rods, even though flexible rods are currently being used for dynamic stabilization. In this study, the risk of breakage of screws for the rods with various flexibilities in pedicle screw fixation systems is investigated by calculating the von Mises stress as a breakage risk factor using finite element analysis. Three-dimensional finite element models of the lumbar spine with posterior one-level spinal fixations at L4-L5 using four types of rod (a straight rod, a 4 mm spring rod, a 3 mm spring rod, and a 2 mm spring rod) were developed. The von Mises stresses in both the pedicle screws and the rods were analysed under flexion, extension, lateral bending, and torsion moments of 10 Nm with a follower load of 400 N. The maximum von Mises stress, which was concentrated on the neck region of the pedicle screw, decreased as the flexibility of the rod increased. However, the ratio of the maximum stress in the rod to the yield stress increased substantially when a highly flexible rod was used. Thus, the level of rod flexibility should be considered carefully when using flexible rods for dynamic stabilization because the intersegmental motion facilitated by the flexible rod results in rod breakage.
Griffiths, Chester F; Cutler, Aaron R; Duong, Huy T; Bardo, Gal; Karimi, Kian; Barkhoudarian, Garni; Carrau, Ricardo; Kelly, Daniel F
2014-07-01
Most endoscopic transsphenoidal approaches jeopardize the sphenopalatine artery and septal olfactory strip (SOS), increasing the risk of postoperative anosmia and epistaxis while precluding the ability to raise pedicled nasoseptal flaps (NSF). We describe a bilateral "rescue flap" technique that preserves the mucosa containing the nasal-septal vascular pedicles and the SOS. This approach can reduce the risk of postoperative complications, including epistaxis and anosmia. A retrospective analysis was conducted of all patients who underwent endoscopic transsphenoidal surgery with preservation of both sphenopalatine vascular pedicles and SOS. In a recent subset of patients, olfactory assessment was performed. Of 174 consecutive operations performed in 161 patients, bilateral preservation of the sphenopalatine vascular pedicle and SOS was achieved in 139 (80 %) operations, including 31 (22 %) with prior transsphenoidal surgery. Of the remaining 35 operations, 18 had a planned formal NSF and 17 had prior surgery or extensive lesions precluding use of this technique. Of pituitary adenomas, RCCs or sellar arachnoid cysts, 118 (94 %) underwent this approach, including 91 % of patients who had prior surgery. Preoperative olfaction function was maintained in 97 % of patients that were tested. None of the patients had postoperative arterial epistaxis. Preservation of bilateral sphenopalatine vascular pedicles and the SOS is feasible in over 90 % of patients undergoing endonasal endoscopic surgery for pituitary adenomas and RCCs. This approach, while not hindering exposure or limiting instrument maneuverability, preserves the nasoseptal vasculature for future NSF use if needed and appears to minimize the risks of postoperative arterial epistaxis and anosmia.
Liu, Kun; Zhang, Qiang; Li, Xin; Zhao, Changsong; Quan, Xuemin; Zhao, Rugang; Chen, Zongfeng; Li, Yansheng
2017-06-01
Accurate implantation of pedicle screw in spinal deformity correction surgeries is always challenging. We have developed a method of pedicle screw placement in severe and rigid scoliosis with a multi-level 3D printing drill guide template. From November 2011 to March 2015, ten patients (4 males and 6 females) with severe and rigid scoliosis (Cobb angle >70° and flexibility <30%)were included. Multi-level template was designed and manufactured according to the part (two or three levels) of the most severe deformity. The drill template was then placed on the corresponding vertebral surface. Then, pedicle screws were carefully inserted along the trajectories. The other screws were placed in free hand. After surgery, the positions of the pedicle screws were evaluated by CT scan and graded for validation. 48 screws were implanted using templates, other 104 screws in free hand, and the accuracies were 93.8 and 78.8%, respectively, with significant difference. The deformity correction ratio was 67.1 and 41.2% in coronal and sagittal plane post-operatively, respectively. The average operation time was 234.0 ± 34.1 min, and average blood loss was 557 ± 67.4 ml. With the application of multi-level template, the incidence of cortex perforation in severe and rigid scoliosis decreased and this technology is, therefore, potentially applicable in clinical practice.
Pedicle screw fixation in spinal disorders: a European view.
Boos, N; Webb, J K
1997-01-01
Continuing controversy over the use of pedicular fixation in the United States is promoted by the lack of governmental approval for the marketing of these devices due to safety and efficacy concerns. These implants have meanwhile become an invaluable part of spinal instrumentation in Europe. With regard to the North American view, there is a lack of comprehensive reviews that consider the historical evolution of pedicle screw systems, the rationales for their application, and the clinical outcome from a European perspective. This literature review suggests that pedicular fixation is a relatively safe procedure and is not associated with a significantly higher complication risk than non-pedicular instrumentation. Pedicle screw fixation provides short, rigid segmental stabilization that allows preservation of motion segments and stabilization of the spine in the absence of intact posterior elements, which is not possible with non-pedicular instrumentation. Fusion rates and clinical outcome in the treatment of thoracolumbar fractures appear to be superior to that achieved using other forms of treatment. For the correction of spinal deformity (i.e., scoliosis, kyphosis, spondylolisthesis, tumor), pedicular fixation provides the theoretical benefit of rigid segmental fixation and of facilitated deformity correction by a posterior approach, but the clinical relevance so far remains unknown. In low-back pain disorders, a literature analysis of 5,600 cases of lumbar fusion with different techniques reveals a trend that pedicle screw fixation enhances the fusion rate but not clinical outcome. The most striking finding in the literature is the large range in the radiological and clinical results. For every single fusion technique poor and excellent results have been described. This review argues that European spine surgeons should begin to back up the evident benefits of pedicle screw systems for specific spinal disorders by controlled prospective clinical trials. This may prevent forthcoming medical licensing authorities from restricting the use of pedicle screw devices and dictating the practice of spinal surgery in Europe in the near future.
Lee, Han-Dong; Jeon, Chang-Hoon; Chung, Nam-Su; Seo, Young-Wook
2017-08-01
A cost-utility analysis (CUA). The aim of this study was to determine the cost-effectiveness of pedicle screw removal after posterior fusion in thoracolumbar burst fractures. Pedicle screw instrumentation is a standard fixation method for unstable thoracolumbar burst fracture. However, removal of the pedicle screw after successful fusion remains controversial because the clinical benefits remain unclear. CUA can help clinicians make appropriate decisions about optimal health care for pedicle screw removal after successful fusion in thoracolumbar burst fractures. We conducted a single-center, retrospective, longitudinal matched-cohort study of prospectively collected outcomes. In total, 88 consecutive patients who had undergone pedicle screw instrumentation for thoracolumbar burst fracture with successful fusion confirmed by computed tomography (CT) were used in this study. In total, 45 patients wanted to undergo implant removal surgery (R group), and 43 decided not to remove the implant (NR group). A CUA was conducted from the health care perspective. The direct costs of health care were obtained from the medical bill of each patient. Changes in health-related quality of life (HRQoL) scores, validated by Short Form 6D, were used to calculate quality-adjusted life-years (QALYs). Total costs and gained QALY were calculated at 1 year (1 year) and 2 years (2 years) compared with baseline. Results are expressed as an incremental cost-effectiveness ratio (ICER). Different discount rates (0%, 3%, and 5%) were applied to both cost and QALY for sensitivity analysis. Baseline patient variables were similar between the two groups (all P > 0.05). The additional benefits of implant removal (0.201 QALY at 2 years) were achieved with additional costs ($2541 at 2 years), equating to an ICER of $12,641/QALY. On the basis of the different discount rates, the robustness of our study's results was also determined. Implant removal after successful fusion in a thoracolumbar burst fracture is cost-effective until postoperative year 2. 3.
Merc, Matjaz; Drstvensek, Igor; Vogrin, Matjaz; Brajlih, Tomaz; Recnik, Gregor
2013-07-01
The method of free-hand pedicle screw placement is generally safe although it carries potential risks. For this reason, several highly accurate computer-assisted systems were developed and are currently on the market. However, these devices have certain disadvantages. We have developed a method of pedicle screw placement in the lumbar and sacral region using a multi-level drill guide template, created with the rapid prototyping technology and have validated it in a clinical study. The aim of the study was to manufacture and evaluate the accuracy of a multi-level drill guide template for lumbar and first sacral pedicle screw placement and to compare it with the free-hand technique under fluoroscopy supervision. In 2011 and 2012, a randomized clinical trial was performed on 20 patients. 54 screws were implanted in the trial group using templates and 54 in the control group using the fluoroscopy-supervised free-hand technique. Furthermore, applicability for the first sacral level was tested. Preoperative CT-scans were taken and templates were designed using the selective laser sintering method. Postoperative evaluation and statistical analysis of pedicle violation, displacement, screw length and deviation were performed for both groups. The incidence of cortex perforation was significantly reduced in the template group; likewise, the deviation and displacement level of screws in the sagittal plane. In both groups there was no significantly important difference in deviation and displacement level in the transversal plane as not in pedicle screw length. The results for the first sacral level resembled the main investigated group. The method significantly lowers the incidence of cortex perforation and is therefore potentially applicable in clinical practice, especially in some selected cases. The applied method, however, carries a potential for errors during manufacturing and practical usage and therefore still requires further improvements.
Interest of intra-operative 3D imaging in spine surgery: a prospective randomized study.
Ruatti, Sébastien; Dubois, C; Chipon, E; Kerschbaumer, G; Milaire, M; Moreau-Gaudry, A; Tonetti, J; Merloz, Ph
2016-06-01
We report a single-center, prospective, randomized study for pedicle screw insertion in opened and percutaneous spine surgeries, using a computer-assisted surgery (CAS) technique with three-dimensional (3D) intra-operative images intensifier (without planification on pre-operative CT scan) vs conventional surgical procedure. We included 143 patients: Group C (conventional, 72 patients) and Group N (3D Fluoronavigation, 71 patients). We measured the pedicle screw running time, and surgeon's radiation exposure. All pedicle runs were assessed according to Heary by two independent radiologists on a post-operative CT scan. 3D Fluoronavigation appeared less accurate in percutaneous procedures (24 % of misplaced pedicle screws vs 5 % in Group C) (p = 0.007), but more accurate in opened surgeries (5 % of misplaced pedicle screws vs 17 % in Group C) (p = 0.025). For one vertebra, the average surgical running time reached 8 min in Group C vs 21 min in Group N for percutaneous surgeries (p = 3.42 × 10(-9)), 7.33 min in Group C vs 16.33 min in Group N (p = 2.88 × 10(-7)) for opened surgeries. The 3D navigation device delivered less radiation in percutaneous procedures [0.6 vs 1.62 mSv in Group C (p = 2.45 × 10(-9))]. For opened surgeries, it was twice higher in Group N with 0.21 vs 0.1 mSv in Group C (p = 0.022). The rate of misplaced pedicle screws with conventional techniques was nearly the same as most papers and a little bit higher with CAS. Surgical running time and radiation exposure were consistent with many studies. Our work hypothesis is partially confirmed, depending on the type of surgery (opened or closed procedure).
Upasani, Vidyadhar V; Chambers, Reid C; Dalal, Ali H; Shah, Suken A; Lehman, Ronald A; Newton, Peter O
2009-08-01
Bench-top and retrospective analysis to assess vertebral rotation based on the appearance of bilateral pedicle screws in patients with adolescent idiopathic scoliosis (AIS). To develop a clinically relevant radiographic grading system for evaluating postoperative thoracic apical vertebral rotation that would correlate with computed tomography (CT) measures of rotation. The 3-column vertebral body control provided by bilateral pedicle screws has enabled scoliosis surgeons to develop advanced techniques of direct vertebral derotation. Our ability to accurately quantify spinal deformity in the axial plane, however, continues to be limited. Trigonometry was used to define the relationship between the position of bilateral pedicle screws and vertebral rotation. This relationship was validated using digital photographs of a bench-top model. The mathematical relationships were then used to calculate vertebral rotation from standing postoperative, posteroanterior radiographs in AIS patients and correlated with postoperative CT measures of rotation. Fourteen digital photographs of the bench-top model were independently analyzed twice by 3 coauthors. The mathematically calculated degree of rotation was found to correlate significantly with the actual degree of rotation (r = 0.99; P < 0.001) and the intra- and interobserver reliability for these measurements were both excellent (kappa = 0.98 and kappa = 0.97, respectively). In the retrospective analysis of 17 AIS patients, the average absolute difference between the radiographic measurement of rotation and the CT measure was only 1.9 degrees +/- 2.0 degrees (r = 0.92; P < 0.001). Based on these correlations a simple radiographic grading system for postoperative apical vertebral rotation was developed. An accurate assessment of vertebral rotation can be performed radiographically, using screw lengths and screw tip-to-rod distances of bilateral segmental pedicle screws and a trigonometric calculation. These data support the use of a simple radiographic grading system to approximate apical vertebral rotation in AIS patients treated with bilateral apical pedicle screws.
Subcutaneous pedicle propeller flap: An old technique revisited and modified!
Karki, Durga; Mehta, Nikhil; Narayan, Ravi Prakash
2016-01-01
Background: Post-burn axillary and elbow scar contracture is a challenging problem to the reconstructive surgeon owing to the wide range of abduction and extension that should be achieved, respectively, while treating either of the joint. The aim of this paper is to highlight the use of subcutaneous pedicle propeller flap for the management of post-burn axillary and elbow contractures. Methodology: This is a prospective case study of axillary and elbow contractures managed at a tertiary care hospital using propeller flap based on subcutaneous pedicle from 2009 to 2014. Surgical treatment comprised of subcutaneous-based pedicle propeller flap from the normal tissue within the contracture based on central axis pedicle. The flap was rotated axially to break the contracture. The technique further encompassed a modification, a Zig-Zag incision of the flap, which was seen to prevent hypertrophy along the incision line. There was a mean period of 12 months of follow-up. Results: Thirty-eight patients consisting of 22 males and 16 females were included in this study among which 23 patients had Type II axillary contractures and 15 had moderate flexion contractures at elbow joint. The post-operative abduction achieved at shoulder joint had a mean of 168° whereas extension achieved at elbow had a mean of 175°. The functional and aesthetic results were satisfactory. Conclusion: The choice of surgical procedure for reconstruction of post-burn upper extremity contractures should be made according to the pattern of scar contracture and the state of surrounding skin. The choice of subcutaneous pedicle propeller flap should be emphasised because of the superior functional results of flap as well as ease to learn it. Moreover, the modification of propeller flap described achieves better results in terms of scar healing. There is an inter-positioning of healthy skin in between the graft, so it prevents scar band formation all around the flap. PMID:27833285
Subcutaneous pedicle propeller flap: An old technique revisited and modified!
Karki, Durga; Mehta, Nikhil; Narayan, Ravi Prakash
2016-01-01
Post-burn axillary and elbow scar contracture is a challenging problem to the reconstructive surgeon owing to the wide range of abduction and extension that should be achieved, respectively, while treating either of the joint. The aim of this paper is to highlight the use of subcutaneous pedicle propeller flap for the management of post-burn axillary and elbow contractures. This is a prospective case study of axillary and elbow contractures managed at a tertiary care hospital using propeller flap based on subcutaneous pedicle from 2009 to 2014. Surgical treatment comprised of subcutaneous-based pedicle propeller flap from the normal tissue within the contracture based on central axis pedicle. The flap was rotated axially to break the contracture. The technique further encompassed a modification, a Zig-Zag incision of the flap, which was seen to prevent hypertrophy along the incision line. There was a mean period of 12 months of follow-up. Thirty-eight patients consisting of 22 males and 16 females were included in this study among which 23 patients had Type II axillary contractures and 15 had moderate flexion contractures at elbow joint. The post-operative abduction achieved at shoulder joint had a mean of 168° whereas extension achieved at elbow had a mean of 175°. The functional and aesthetic results were satisfactory. The choice of surgical procedure for reconstruction of post-burn upper extremity contractures should be made according to the pattern of scar contracture and the state of surrounding skin. The choice of subcutaneous pedicle propeller flap should be emphasised because of the superior functional results of flap as well as ease to learn it. Moreover, the modification of propeller flap described achieves better results in terms of scar healing. There is an inter-positioning of healthy skin in between the graft, so it prevents scar band formation all around the flap.
Oksüz, Sinan; Ulkür, Ersin; Tuncer, Serhan; Sever, Celalettin; Karagöz, Hüseyin
2013-04-01
The complexity of managing large soft-tissue defects at the elbow region by conventional techniques arises from the difficulty of providing sufficient tissue with adequate elasticity and durability. Reconstruction options that allow early mobilisation and avoid the risk of functional loss should be considered to achieve defect closure at the elbow region. A 21-year-old man presented with a congenital giant hairy nevus on his left upper extremity. The nevus was excised and the resulting raw surface after the excision was covered with a split-thickness skin graft except for the elbow region. The elbow was covered in one stage with an ipsilateral 24 cm long pedicled thoracodorsal artery perforator (TDAP) flap. The follow-up examination 3 years after total reconstruction demonstrated durable elbow support provided by the TDAP flap. The patient revealed no complaint considering pain or sensitivity even when exposed to mechanical stress. Split-thickness skin grafting of the large superficial defects is almost always possible; however, impairment of the function on joint areas due to gradual contraction and skin graft propensity to ulcers under mechanical stresses can be devastating. The elbow is a weight-bearing area of the body. Elbow defects require durable and thin soft-tissue coverage and the tissue cover must possess excellent elastic properties to re-establish elbow mobility. The TDAP flap is an ideal choice for elbow soft-tissue defects. The longest pedicle length reported for the TDAP flap is 23 cm. In our case, the pedicle length was 24 cm and it was possible to transfer this flap to the elbow on its pedicle. A pedicled TDAP skin flap so as to provide elbow coverage in one stage is a useful choice to retain in one's armamentarium. Copyright © 2012 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Macke, Jeremy J; Woo, Raymund; Varich, Laura
2016-06-01
This is a retrospective review of pedicle screw placement in adolescent idiopathic scoliosis (AIS) patients under 18 years of age who underwent robot-assisted corrective surgery. Our primary objective was to characterize the accuracy of pedicle screw placement with evaluation by computed tomography (CT) after robot-assisted surgery in AIS patients. Screw malposition is the most frequent complication of pedicle screw placement and is more frequent in AIS. Given the potential for serious complications, the need for improved accuracy of screw placement has spurred multiple innovations including robot-assisted guidance devices. No studies to date have evaluated this robot-assisted technique using CT exclusively within the AIS population. Fifty patients were included in the study. All operative procedures were performed at a single institution by a single pediatric orthopedic surgeon. We evaluated the grade of screw breach, the direction of screw breach, and the positioning of the patient for preoperative scan (supine versus prone). Of 662 screws evaluated, 48 screws (7.2 %) demonstrated a breach of greater than 2 mm. With preoperative prone position CT scanning, only 2.4 % of screws were found to have this degree of breach. Medial malposition was found in 3 % of screws, a rate which decreased to 0 % with preoperative prone position scanning. Based on our results, we conclude that the proper use of image-guided robot-assisted surgery can improve the accuracy and safety of thoracic pedicle screw placement in patients with adolescent idiopathic scoliosis. This is the first study to evaluate the accuracy of pedicle screw placement using CT assessment in robot-assisted surgical correction of patients with AIS. In our study, the robot-assisted screw misplacement rate was lower than similarly constructed studies evaluating conventional (non-robot-assisted) procedures. If patients are preoperatively scanned in the prone position, the misplacement rate is further decreased.
Yang, Ming; Zhao, Qinpeng; Hao, Dingjun; Chang, Zhen; Liu, Shichang; Yin, Xinhua
2018-06-16
To compare the efficacy and safety of novel percutaneous minimally invasive pedicle screw fixation and traditional open surgery for thoracolumbar fractures without neurological deficit. Sixty adult patients with single thoracolumbar fracture between June 2014 and June 2016 were recruited in this study, randomly divided into open fixation group (group A) or minimally invasive percutaneous fixation group (group B). Clinical and surgical evaluation including surgery time, blood losses, radiation times, hospital stay, and complication were performed. The two groups of patients with pre-operative and last follow-up anterior height ratio of fracture vertebral, Cobb angle of fracture vertebral, and VAS score of back pain were compared. All patients completed valid follow-ups, with an average time period of 15.4 months (12-26 months). Group B achieved much better results in time of operation, intra-operative blood loss, and length of stay than group A (P < 0.05). Group A was significantly better than group B in the times of radiation (P < 0.05). The VAS score was significantly lower in group B than in group A at three days after the operation (P < 0.05). There were no significant differences between the two groups in the anterior height ratio of fracture vertebral, Cobb angle, and VAS score in the last follow-up (P > 0.05). No injured nerve or other severe complications occurred in both groups; one of the patients from group A had back and loin pain lasting for about one month, which resolved after analgesia and functional training. There was no significant difference between the two groups in incidence of complications. Novel percutaneous pedicle screws with angle reset function can achieve the same effect as traditional open pedicle screw fixation in the treatment of thoracolumbar fractures without nerve injuries. Percutaneous minimally invasive pedicle screw fixation has the characteristics of shorter operative time, less bleeding, and less pain, but it needs more radiation times.
Mattyasovszky, S G; Kurth, A A; Drees, P; Gemidji, J; Thomczyk, S; Kafchitsas, K
2014-10-01
Minimally invasive cement augmentation of painful osteoporotic vertebral compression fractures in elderly patients. Painful osteoporotic vertebral compression fractures in elderly patients (> 65 years of age) after conservative therapy failure. Painful aggressive primary tumors of the spine or osteolytic metastases to the spine with high risk of vertebral fracture in the palliative care setting. General contraindications for surgical interventions. Local soft-tissue infection. Osteomyelitis, discitis or systemic infection. Coagulopathy refractory to treatment or bleeding diathesis. Asymptomatic vertebral compression fractures. Burst of the posterior vertebral column with high degree of spinal canal stenosis. Primary or metastatic spinal tumors with epidural growth. Prone position on a radiolucent operating table. Fluoroscopic localization of the fractured vertebra using two conventional C-arm devices (anteroposterior and lateral views). Fluoroscopic localization of the fractured vertebra using two conventional C-arm devices (anteroposterior and lateral views). An introducer is inserted through a small skin incision into the pedicle under fluoroscopic guidance. To create a site- and size-specific three-dimensional cavity in the center of the fractured vertebra, the navigational VertecoR™ MidLine Osteotome was inserted through the correctly sited introducer and guided fluoroscopically. As the MidLine Osteotome allows angulation of the tip up to 90° by rotating the handle, a cavity over the midline of the vertebral body can mainly be created through one pedicle. The radiofrequency activated cohesive ultrahigh viscosity PMMA cement (ER(2) bone cement) is injected stepwise on demand by remote control under continuous pressure from the hydraulic assembly into the vertebral body. Bed rest for 6 h postoperatively in supine position. Early mobilization without a corset on the day of surgery. Specific back and abdominal exercises that strengthen the back and abdominal muscles. Pain dependent increase of weight bearing. Continue osteoporosis therapy and start specific drug therapy according to the local guidlines if necessary. In all, 44 patients (29 women, 15 men) with a mean age of 73.5 years with a total of 62 painful osteoporotic vertebral fractures were treated with RF kyphoplasty from May 2009 until July 2010, and followed over a period of 12 months. The mean operating time per patient was 36.2 min, the operating time per vertebra was 25.7 min. All the patients studied experienced an early and persistent significant pain relief even 12 months after therapy (8 ± 1.4 vs. 2.7 ± 1.9) according to the visual analogue pain scale. According to the Oswestry Disability Index (ODI) as a disease-specific disability measure all the patients improved significantly (p < 0.001) in the level of disability after operative treatment (56.2 ± 18.8 vs. 34.5 ± 16.6). Cement leakage was detected in 17 out of 62 (27.4 %) augmented vertebrae, whereas all the patients with cement leakage remained asymptomatic. One patient had subsequent vertebral fractures after a period of 6 months.
Fogel, Guy R; Parikh, Rachit D; Ryu, Stephen I; Turner, Alexander W L
2014-03-01
Lumbar interbody fusion is indicated in the treatment of degenerative conditions. Laterally inserted interbody cages significantly decrease range of motion (ROM) compared with other cages. Supplemental fixation options such as lateral plates or spinous process plates have been shown to provide stability and to reduce morbidity. The authors of the current study investigate the in vitro stability of the interbody cage with a combination of lateral and spinous process plate fixation and compare this method to the established bilateral pedicle screw fixation technique. Ten L1-5 specimens were evaluated using multidirectional nondestructive moments (± 7.5 N · m), with a custom 6 degrees-of-freedom spine simulator. Intervertebral motions (ROM) were measured optoelectronically. Each spine was evaluated under the following conditions at the L3-4 level: intact; interbody cage alone (stand-alone); cage supplemented with lateral plate; cage supplemented with ipsilateral pedicle screws; cage supplemented with bilateral pedicle screws; cage supplemented with spinous process plate; and cage supplemented with a combination of lateral plate and spinous process plate. Intervertebral rotations were calculated, and ROM data were normalized to the intact ROM data. The stand-alone laterally inserted interbody cage significantly reduced ROM with respect to the intact state in flexion-extension (31.6% intact ROM, p < 0.001), lateral bending (32.5%, p < 0.001), and axial rotation (69.4%, p = 0.002). Compared with the stand-alone condition, addition of a lateral plate to the interbody cage did not significantly alter the ROM in flexion-extension (p = 0.904); however, it was significantly decreased in lateral bending and axial rotation (p < 0.001). The cage supplemented with a lateral plate was not statistically different from bilateral pedicle screws in lateral bending (p = 0.579). Supplemental fixation using a spinous process plate was not significantly different from bilateral pedicle screws in flexion-extension (p = 0.476). The combination of lateral plate and spinous process plate was not statistically different from the cage supplemented with bilateral pedicle screws in all the loading modes (p ≥ 0.365). A combination of lateral and spinous process plate fixation to supplement a laterally inserted interbody cage helps achieve rigidity in all motion planes similar to that achieved with bilateral pedicle screws.
Gallizzi, Michael A.; Kuhns, Craig A.; Jenkins, Tyler J.; Pfeiffer, Ferris M.
2014-01-01
Study Design Biomechanical analysis of lateral mass screw pullout strength. Objective We compare the pullout strength of our bone cement–revised lateral mass screw with the standard lateral mass screw. Methods In cadaveric cervical spines, we simulated lateral mass screw “cutouts” unilaterally from C3 to C7. We salvaged fixation in the cutout side with polymethyl methacrylate (PMMA) or Cortoss cement (Orthovita, Malvern, Pennsylvania, United States), allowed the cement to harden, and then drilled and placed lateral mass screws back into the cement-augmented lateral masses. On the contralateral side, we placed standard lateral mass screws into the native, or normal lateral, masses and then compared pullout strength of the cement-augmented side to the standard lateral mass screw. For pullout testing, each augmentation group was fixed to a servohydraulic load frame and a specially designed pullout fixture was attached to each lateral mass screw head. Results Quick-mix PMMA-salvaged lateral mass screws required greater force to fail when compared with native lateral mass screws. Cortoss cement and PMMA standard-mix cement-augmented screws demonstrated less strength of fixation when compared with control-side lateral mass screws. Attempts at a second round of cement salvage of the same lateral masses led to more variations in load to failure, but quick-mix PMMA again demonstrated greater load to failure when compared with the nonaugmented control lateral mass screws. Conclusion Quick-mix PMMA cement revision equips the spinal surgeon with a much needed salvage option for a failed lateral mass screw in the subaxial cervical spine. PMID:25649421
Kawaguchi, Yoshiharu; Nakano, Masato; Yasuda, Taketoshi; Seki, Shoji; Hori, Takeshi; Kimura, Tomoatsu
2012-11-01
We developed a new technique for cervical pedicle screw and Magerl screw insertion using a 3-dimensional image guide. In posterior cervical spinal fusion surgery, instrumentation with screws is virtually routine. However, malpositioning of screws is not rare. To avoid complications during cervical pedicle screw and Magerl screw insertion, the authors developed a new technique which is a mold shaped to fit the lamina. Cervical pedicle screw fixation and Magerl screw fixation provide good correction of cervical alignment, rigid fixation, and a high fusion rate. However, malpositioning of screws is not a rare occurrence, and thus the insertion of screws has a potential risk of neurovascular injury. It is necessary to determine a safe insertion procedure for these screws. Preoperative computed tomographic (CT) scans of 1-mm slice thickness were obtained of the whole surgical area. The CT data were imported into a computer navigation system. We developed a 3-dimensional full-scale model of the patient's spine using a rapid prototyping technique from the CT data. Molds of the left and right sides at each vertebra were also constructed. One hole (2.0 mm in diameter and 2.0 cm in length) was made in each mold for the insertion of a screw guide. We performed a simulated surgery using the bone model and the mold before operation in all patients. The mold was firmly attached to the surface of the lamina and the guide wire was inserted using the intraoperative image of lateral vertebra. The proper insertion point, direction, and length of the guide were also confirmed both with the model bone and the image intensifier in the operative field. Then, drilling using a cannulated drill and tapping using a cannulated tapping device were carried out. Eleven consecutive patients who underwent posterior spinal fusion surgery using this technique since 2009 are included. The screw positions in the sagittal and axial planes were evaluated by postoperative CT scan to check for malpositioning. The screw insertion was done in the same manner as the simulated surgery. With the aid of this guide the pedicle screws and Magerl screws could be easily inserted even at the level where the pedicle seemed to be very thin and sclerotic on the CT scan. Postoperative CT scan showed that there were no critical breaches of the screws. This method employing the device using a 3-dimensional image guide seems to be easy and safe to use. The technique may improve the safety of pedicle screw and Magerl screw insertion even in difficult cases with narrow sclerotic pedicles.
Yilmaz, Guney; Borkhuu, Battugs; Dhawale, Arjun A; Oto, Murat; Littleton, Aaron G; Mason, Dan E; Gabos, Peter G; Shah, Suken A
2012-01-01
Spinal instrumentation in adolescent idiopathic scoliosis (AIS) aims to correct spinal deformity and maintain long-term spinal stability until bony healing is ensured. The purpose of this study was to compare the minimum 2-year postoperative radiographic and clinical results of posterior spine correction and fusion with all-hook instrumentation versus hybrid segmental instrumentation versus pedicle screw instrumentation for AIS from a single institution. A total of 105 patients with AIS who underwent a posterior spinal fusion with segmental pedicle screw (35), hook (35), or hybrid (35) instrumentation were sorted and matched according to the following criteria: similar age at surgery, identical Lenke curve types, curve magnitude, and Risser grade. Patients were evaluated before, immediately after, and at 2 years after surgery for radiographic parameters, complications, and outcome, as well as on the basis of the Scoliosis Research Society (SRS) questionnaire. The age and Risser grade, major curve Cobb angle, apical vertebral rotation (AVR), apical vertebral translation (AVT), lowest instrumented vertebral tilt, global coronal and sagittal balance, lumbar lordosis, and thoracic kyphosis were determined as part of preoperative evaluation. All 3 groups showed significant differences between the preoperative and postoperative major curve Cobb angle, lowest instrumented vertebral tilt, AVT, and AVR. At the latest follow-up, lumbar lordosis, thoracic kyphosis, and global coronal and sagittal balance remained similar among the 3 groups. Major curve Cobb angle, AVT, and AVR were significantly different--the hook group's measurements were significantly higher than the other groups, but there was no difference between the pedicle screw and hybrid groups. Major curve correction rate was significantly different among all groups (screw=71.9%±13.8%, hybrid=61.4%±16.6%, hook=48.1%±19.7%) (P<0.001). The pedicle screw group had the least amount of correction loss but there was no statistically significant difference between groups (screw=2.6±6.7 degrees, hybrid=4.5±7.4 degrees, hook=4.4±6.2 degrees) (P=0.35). The hook group had the least amount of AVT correction, but the screw group and the hybrid groups were similar (pedicle=67.3%±15.5%, hybrid=57.5%±22.4%, hook=39.9%±32.5%) (P<0.001). Surgery time and blood loss were higher in the screw group. No differences in global SRS-22 scores were demonstrated between the patients treated with pedicle screw, hybrid, and hook constructs; however, the satisfaction domain was higher in the screw group at the latest follow-up. Pedicle screw and hybrid instrumentations offer significantly better spinal deformity correction than hook constructs in major curve coronal correction, AVT, and AVR. Patients with pedicle screw instrumentation had the greatest curve correction percentage, maintenance of this correction in the coronal and sagittal planes, and higher patient satisfaction by the SRS outcome scores. Global SRS-22 scores were similar at 2-year follow-up in all groups. Therapeutic level III retrospective comparative study.
Timing of distant flap pedicle division using xenon 133 clearance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Snelling, C.F.; Poomee, A.; Sutherland, J.B.
1980-09-01
Clearance of intradermally injected xenon 133 was used to measure blood flow in distant flaps in humans with the donor pedicle temporarily clamped just prior to division. All 18 flaps with a blood flow of 0.5 ml per 100 gm of tissue per minute or more survived completely after separation. Of 7 with lesser flow, 3 underwent marginal necrosis adjacent to the line of division and 4 survived entirely. Xenon 133 washout does permit quantitative evaluation of blood flow, and since it is a clean isotope, it appears superior to sodium 24 and technetium 99m, which have been used inmore » a similar manner. The test is proposed as an adjunct to clinical judgment in timing pedicle division.« less
Spinal pedicle subtraction osteotomy for fixed sagittal imbalance patients
Hyun, Seung-Jae; Kim, Yongjung J; Rhim, Seung-Chul
2013-01-01
In addressing spinal sagittal imbalance through a posterior approach, the surgeon now may choose from among a variety of osteotomy techniques. Posterior column osteotomies such as the facetectomy or Ponte or Smith-Petersen osteotomy provide the least correction, but can be used at multiple levels with minimal blood loss and a lower operative risk. Pedicle subtraction osteotomies provide nearly 3 times the per-level correction of Ponte/Smith-Petersen osteotomies; however, they carry increased technical demands, longer operative time, and greater blood loss and associated significant morbidity, including neurological injury. The literature focusing on pedicle subtraction osteotomy for fixed sagittal imbalance patients is reviewed. The long-term overall outcomes, surgical tips to reduce the complications and suggestions for their proper application are also provided. PMID:24340276
Huang, Meng; Barber, Sean Michael; Steele, William James; Boghani, Zain; Desai, Viren Rajendrakumar; Britz, Gavin Wayne; West, George Alexander; Trask, Todd Wilson; Holman, Paul Joseph
2018-06-01
Image-guided approaches to spinal instrumentation and interbody fusion have been widely popularized in the last decade [1-5]. Navigated pedicle screws are significantly less likely to breach [2, 3, 5, 6]. Navigation otherwise remains a point reference tool because the projection is off-axis to the surgeon's inline loupe or microscope view. The Synaptive robotic brightmatter drive videoexoscope monitor system represents a new paradigm for off-axis high-definition (HD) surgical visualization. It has many advantages over the traditional microscope and loupes, which have already been demonstrated in a cadaveric study [7]. An auxiliary, but powerful capability of this system is projection of a second, modifiable image in a split-screen configuration. We hypothesized that integration of both Medtronic and Synaptive platforms could permit the visualization of reconstructed navigation and surgical field images simultaneously. By utilizing navigated instruments, this configuration has the ability to support live image-guided surgery or real-time navigation (RTN). Medtronic O-arm/Stealth S7 navigation, MetRx, NavLock, and SureTrak spinal systems were implemented on a prone cadaveric specimen with a stream output to the Synaptive Display. Surgical visualization was provided using a Storz Image S1 platform and camera mounted to the Synaptive robotic brightmatter drive. We were able to successfully technically co-adapt both platforms. A minimally invasive transforaminal lumbar interbody fusion (MIS TLIF) and an open pedicle subtraction osteotomy (PSO) were performed using a navigated high-speed drill under RTN. Disc Shaver and Trials under RTN were implemented on the MIS TLIF. The synergy of Synaptive HD videoexoscope robotic drive and Medtronic Stealth platforms allow for live image-guided surgery or real-time navigation (RTN). Off-axis projection also allows upright neutral cervical spine operative ergonomics for the surgeons and improved surgical team visualization and education compared to traditional means. This technique has the potential to augment existing minimally invasive and open approaches, but will require long-term outcome measurements for efficacy.
The complicated role of venous drainage on the survival of arterialized venous flaps
Weng, Weidong; Zhang, Feng; Zhao, Bin; Wu, Zhipeng; Gao, Weiyang; Li, Zhijie; Yan, Hede
2017-01-01
The arterialized venous flap (AVF) has been gradually popularized in clinical settings; however, its survival is still inconsistent and the role of venous drainage remains elusive. In this study, we aimed to investigate the role of venous drainage on the flap survival of arterialized venous flaps. An arterialized venous flap was outlined symmetrically in the rabbit abdomen. The arterial perfusion flap with a unilateral vascular pedicle was taken as the control group and three other experimental groups (I, II and III) were designed based on the number of drainage veins (n = 1, 2 and 3 in the three groups, respectively). Compared with the control group, significant venous congestion was noted in all the experimental groups and the most severe one was seen in group I; while no statistical difference was observed between groups II and III. Similar results regarding blood perfusion state, epidermal metabolite levels and flap survival status were obtained among the three groups. These findings suggested that venous drainage is vital in the survival of the flap, but unlike in the arterial perfusion flaps, the problem of venous congestion can only be partially solved by increasing the number of draining veins. Further studies are warranted to gain insight into this complicated issue. PMID:28145882
Assessment of Renal Ischemia By Optical Spectroscopy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fitzgerald, J T; Demos, S; Michalopoulou, A
2004-01-07
Introduction: No reliable method currently exists for quantifying the degree of warm ischemia in kidney grafts prior to transplantation. We describe a method for evaluating pretransplant warm ischemia time using optical spectroscopic methods. Methods: Lewis rat kidney vascular pedicles were clamped unilaterally in vivo for 0, 5, 10, 20, 30, 60, 90 or 120 minutes; 8 animals were studied at each time point. Injured and contra-lateral control kidneys were then flushed with Euro-Collins solution, resected and placed on ice. 335 nm excitation autofluorescence as well as cross polarized light scattering images were taken of each injured and control kidney usingmore » filters of various wavelengths. The intensity ratio of the injured to normal kidneys was compared to ischemia time. Results: Autofluorescence intensity ratios through a 450 nm filter and light scattering intensity ratios through an 800 nm filter both decreased significantly with increasing ischemia time (p < 0.0001 for each method, one-way ANOVA). All adjacent and non-adjacent time points between 0 and 90 minutes were distinguishable using one of these two modalities by Fisher's PLSD. Conclusions: Optical spectroscopic methods can accurately quantify warm ischemia time in kidneys that have been subsequently hypothermically preserved. Further studies are needed to correlate results with physiological damage and posttransplant performance.« less
Comparing five alternative methods of breast reconstruction surgery: a cost-effectiveness analysis.
Grover, Ritwik; Padula, William V; Van Vliet, Michael; Ridgway, Emily B
2013-11-01
The purpose of this study was to assess the cost-effectiveness of five standardized procedures for breast reconstruction to delineate the best reconstructive approach in postmastectomy patients in the settings of nonirradiated and irradiated chest walls. A decision tree was used to model five breast reconstruction procedures from the provider perspective to evaluate cost-effectiveness. Procedures included autologous flaps with pedicled tissue, autologous flaps with free tissue, latissimus dorsi flaps with breast implants, expanders with implant exchange, and immediate implant placement. All methods were compared with a "do-nothing" alternative. Data for model parameters were collected through a systematic review, and patient health utilities were calculated from an ad hoc survey of reconstructive surgeons. Results were measured in cost (2011 U.S. dollars) per quality-adjusted life-year. Univariate sensitivity analyses and Bayesian multivariate probabilistic sensitivity analysis were conducted. Pedicled autologous tissue and free autologous tissue reconstruction were cost-effective compared with the do-nothing alternative. Pedicled autologous tissue was the slightly more cost-effective of the two. The other procedures were not found to be cost-effective. The results were robust to a number of sensitivity analyses, although the margin between pedicled and free autologous tissue reconstruction is small and affected by some parameter values. Autologous pedicled tissue was slightly more cost-effective than free tissue reconstruction in irradiated and nonirradiated patients. Implant-based techniques were not cost-effective. This is in agreement with the growing trend at academic institutions to encourage autologous tissue reconstruction because of its natural recreation of the breast contour, suppleness, and resiliency in the setting of irradiated recipient beds.
Wei, Jiao; Herrler, Tanja; Gu, Bin; Yang, Mei; Li, Qingfeng; Dai, Chuanchang; Xie, Feng
2018-05-01
The repair of extensive upper limb skin lesions in pediatric patients is extremely challenging due to substantial limitations of flap size and donor-site morbidity. We aimed to create an oversize preexpanded flap based on intercostal artery perforators for large-scale resurfacing of the upper extremity in children. Between March 2013 and August 2016, 11 patients underwent reconstructive treatment for extensive skin lesions in the upper extremity using a preexpanded intercostal artery perforator flap. Preoperatively, 2 to 4 candidate perforators were selected as potential pedicle vessels based on duplex ultrasound examination. After tissue expander implantation in the thoracodorsal area, regular saline injections were performed until the expanded flap was sufficient in size. Then, a pedicled flap was formed to resurface the skin lesion of the upper limb. The pedicles were transected 3 weeks after flap transfer. Flap survival, complications, and long-term outcome were evaluated. The average time of tissue expansion was 133 days with a mean final volume of 1713 mL. The thoracoabdominal flaps were based on 2 to 6 pedicles and used to resurface a mean skin defect area of 238 cm ranging from 180 to 357 cm. In all cases, primary donor-site closure was achieved. Marginal necrosis was seen in 5 cases. The reconstructed limbs showed satisfactory outcome in both aesthetic and functional aspects. The preexpanded intercostal artery perforator flap enables 1-block repair of extensive upper limb skin lesions. Due to limited donor-site morbidity and a pedicled technique, this resurfacing approach represents a useful tool especially in pediatric patients.
Measurement of the volume of the pedicled TRAM flap in immediate breast reconstruction.
Chang, K P; Lin, S D; Hou, M F; Lee, S S; Tsai, C C
2001-12-01
The transverse rectus abdominis musculocutaneous (TRAM) flap is now accepted as the standard for breast reconstruction, but achieving symmetrical breast reconstruction is still a challenge. A precise estimate of the volume of the flap is necessary to reconstruct a symmetrical and aesthetically pleasing breast. Many methods have been developed to overcome this problem, but they have not been suitable for the pedicled TRAM flap. By using a self-made device based on the Archimedes' principle, the authors can calculate accurately the volume of the pedicled TRAM flap and predict reliably the breast volume intraoperatively. The "procedure" is based on a self-made box into which the pedicled TRAM flap is placed. Warm saline is added to the box and the flap is then removed. Flap volume is calculated easily by determining the difference between the preestimated volume of the box and the volume of the residual water. From February to May 2000, this method was used on 28 patients to predict breast volume for breast reconstruction. This study revealed that the difference of the maximal chest circumferences (the index of the breast volume) demonstrates a positive correlation with the difference of the volumes and weights between the mastectomy specimen and the net TRAM flap. However, a more closely positive correlation exists between the differences of maximal chest circumference volume (r = 0.677) than maximal chest circumference weight (r = 0.618). These data reveal that the reconstructed breast's volume has a closer relationship with the volume of the net pedicled TRAM flap, rather than with its weight.
Wan, Shiyong; Wu, Zixiang; Liu, Da; Gao, Mingxuan; Fu, Suochao
2010-01-01
Transpedicular fixation can be challenging in the osteoporotic spine as reduced bone mineral density compromises the mechanical stability of the pedicle screw. Here, we sought to investigate the biomechanical and histological properties of stabilization of expandable pedicle screw (EPS) in the osteoporotic spine in sheep. EPSs and standard pedicle screws, SINO screws, were inserted on the vertebral bodies in four female ovariectomized sheep. Pull-out and cyclic bending resistance test were performed to compare the holding strength of these pedicle screws. High-resolution micro-computed tomography (CT) was performed for three-dimensional image reconstruction. We found that the EPSs provided a 59.6% increase in the pull-out strength over the SINO screws. Moreover, the EPSs withstood a greater number of cycles or load with less displacement before loosening. Micro-CT image reconstruction showed that the tissue mineral density, bone volume fraction, bone surface/bone volume ratio, trabecular thickness, and trabecular separation were significantly better in the expandable portion of the EPSs than those in the anterior portion of the SINO screws (P < 0.05). Furthermore, the trabecular architecture in the screw–bone interface was denser in the expandable portion of the EPS than that in the anterior portion of the SINO screw. Histologically, newly formed bone tissues grew into the center of EPS and were in close contact with the EPS. Our results show that the EPS demonstrates improved biomechanical and histological properties over the standard screw in the osteoporotic spine. The EPS may be of value in treating patients with osteoporosis and warrants further clinical studies. PMID:20577766
Park, Sang Min; Kim, Ho Joong; Lee, Se Yeon; Chang, Bong Soon; Lee, Choon Ki; Yeom, Jin S
2018-05-01
We prospectively assessed the early radiographic and clinical outcomes (minimum follow-up of 2 years) of robot-assisted pedicle screw fixation (Robot-PSF) and conventional freehand pedicle screw fixation (Conv-PSF). Patients were randomly assigned to Robot-PSF (37 patients) or Conv-PSF (41 patients) for posterior interbody fusion surgery. The Robot-PSF group underwent minimally invasive pedicle screw fixation using a pre-planned robot-guided screw trajectory. The Conv-PSF underwent screw fixation using the freehand technique. Radiographic adjacent segment degeneration (ASD) was measured on plain radiographs, and clinical outcomes were measured using visual analogue scale (VAS) and Oswestry disability index (ODI) scores regularly after surgery. The two groups had similar values for radiographic ASD, including University California at Los Angeles grade, vertebral translation, angular motion, and loss of disc height (p=0.320). At final follow-up, both groups had experienced significant improvements in back VAS, leg VAS, and ODI scores after surgery (p<0.001), although inter-group differences were not significant for back VAS (p=0.876), leg VAS (p=0.429), and ODI scores (p=0.952). In the Conv-PSF group, revision surgery was required for two of the 25 patients (8%), compared to no patients in the Robot-PSF group. There were no significant differences in radiographic ASD and clinical outcomes between Robot-PSF and Conv-PSF. Thus, the advantages of robot-assisted surgery (accurate pedicle screw insertion and minimal facet joint violation) do not appear to be clinically significant. © Copyright: Yonsei University College of Medicine 2018.
Intra-operative localisation of thoracic spine level: a simple "'K'-wire in pedicle" technique.
Thambiraj, Sathya; Quraishi, Nasir A
2012-05-01
To describe a simple and reliable method of intra-operative localisation of thoracic spine in a single surgical setting. Intra-operative localisation of thoracic spine levels can be difficult due to anatomical constraints, such as scapular shadow, patient's size and poor bone quality. This is particularly true in cases of thoracic discectomies in which the vertebral bodies appear normal. There are several methods described in recent literature to address this. Many of them require a separate procedure which was performed often the previous day. We report a technique which addresses the issue of localising thoracic level intra-operatively. After induction of general anaesthesia, the patient was placed prone and the pedicle of interest was identified using fluoroscopy. A K-wire was then inserted percutaneously into this pedicle under image guidance [confirmed in the antero-posterior (AP) and lateral views]. The wire was then cut close to the skin after bending it. The patient was now positioned laterally and the intended procedure performed through an anterior trans-thoracic approach. The 'K' wire was removed at the end of the procedure. We routinely used this technique in all our thoracic discectomies (four cases in 2 years). There were no intra-operative complications. This method is simple, avoids the patient undergoing two procedures and requires no more ability than placing an implant in the pedicle under fluoroscopy. Placing the 'K' wire into a fixed point like the pedicle facilitates rapid intra-operative viewing of the level of interest and is removed easily at the conclusion of surgery.
Kanhai, Robert C J
2016-04-01
The cosmetic and functional results of vaginoplasty by inversion of penile and scrotal skin in male-to-female transsexuals are, in general, satisfactory. The sexual arousal function of the neo-female genitalia depends mainly on the clitoris. Due to the lack of a sexual arousal organ within the neo-vagina, patients are denied sexual arousal during penetration of the neo-vagina. This necessitated improvement of sexual innervation within the neo-vagina. A new technique to create a sexual arousal organ in the anterior wall of the neo-vagina by creation of a sensate pedicled-spot, in combination with the neo-clitoroplasty. In this paper, this new technique and part of the long-term results in the first 50 patients with a sensate pedicled-spot plasty are presented and discussed. Sensate pedicled-spot plasty has proven to be a safe innovative technique which lead to adequate sexual functionality in all patients. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.
Zhou, Jianyin; Liu, Pingguo; Yin, Zhenyu; Zhao, Yilin; Wang, Xiaomin
2013-09-01
The expense of laparoscopic splenectomy (LS) has limited its use in developing countries, while medical costs are increasing worldwide. In this study, we performed LS by secondary pedicle division using monopolar electrocautery to achieve cost savings. Over seven years, we performed 45 consecutive LSs by secondary pedicle division using monopolar electrocautery (n=17) or ultrasonic shears (n=28) at a single center. These were reviewed to assess outcome and cost. Mean operating time was 179.7min, 7 conversions to open operation (15.6%) were necessary. There were four postoperative complications (8.9%) and no deaths. Twenty-three of 28 (82.1%) patients with idiopathic thrombocytopenic purpura developed a long-term positive response; and mean operative cost was RMB6,577 (US$1,034), which was much lower than that of Endo-GIATM in published reports. Between the monopolar electrocautery and ultrasonic shears groups, there were no significant differences in demographic characteristics or intraoperative and postoperative details, but operative cost was significantly lower in the former (RMB4,416, US$696 vs. RMB7,889, US$1,243; p<0.01). LS by secondary pedicle division using monopolar electrocautery is safe, efficacious and economical.
Dawei, Tian; Na, Liu; Jun, Lei; Wei, Jin; Lin, Cai
2013-02-01
Although there were many different types of fixation techniques for sacroiliac dislocation fracture, the treat remained challenging in posterior pelvic ring injury. The purpose of this study was to evaluate the biomechanical effects of a novel fixation system we designed. 12 human cadavers (L3-pelvic-femora) were used to compare biomechanical stability after reconstruction on the same specimens in four conditions: (1) intact, (2) cable system, (3) plate-pedicle screw system, and (4) cable system and plate-pedicle screw combination system (combination system). Biomechanical testing was performed on a material testing machine for evaluating the stiffness of the pelvic fixation construct in compression and torsion. The cable system and plate-pedicle screw system alone may be insufficient to resist vertical shearing and rotational loads; however the combination system for unstable sacroiliac dislocation fractures provided significantly greater stability than single plate-pedicle or cable fixation system. The novel fixation system for unstable sacroiliac dislocation fractures produced sufficient stability in axial compression and axial rotation test in type C pelvic ring injuries. It may also offer a better solution for sacroiliac dislocation fractures. Copyright © 2012 Elsevier Ltd. All rights reserved.
ZHOU, WEI; KONG, WEIQING; ZHAO, BIZHEN; FU, YISHAN; ZHANG, TAO; XU, JIANGUANG
2013-01-01
The aim of this study was to investigate the method of posterior thoracolumbar vertebral pedicle screw reduction and fixation combined with vertebral bone implantation via the affected vertebral body under navigational aid for the treatment of thoracolumbar fractures. The efficacy of the procedure was also measured. Between June 2005 and March 2011, posterior thoracolumbar vertebral pedicle screw reduction and fixation plus artificial bone implantation via the affected vertebral pedicle under navigational aid was used to treat 30 patients with thoracolumbar fractures, including 18 males and 12 females, ranging in age from 21 to 57 years. Compared with the values prior to surgery, intraspinal occupation, vertebral height ratio and Cobb angle at the follow-up were significantly improved. At the long-term follow-up, the postoperative Cobb angle loss was <1° and the anterior vertebral body height loss was <2 mm. Posterior thoracolumbar vertebral pedicle screw reduction and fixation combined with vertebral bone implantation via the affected vertebral body under navigational aid may increase the accuracy and safety of surgery, and it is an ideal method of internal implantation. Bone implantation via the affected vertebral body may increase vertebral stability. PMID:23935737
Preoperative Embolization of Extra-axial Hypervascular Tumors with Onyx
Fusco, Matthew R.; Salem, Mohamed M.; Reddy, Arra S.; Ogilvy, Christopher S.; Kasper, Ekkehard M.; Thomas, Ajith J.
2016-01-01
Objective Preoperative endovascular embolization of intracranial tumors is performed to mitigate anticipated intraoperative blood loss. Although the usage of a wide array of embolic agents, particularly polyvinyl alcohol (PVA), has been described for a variety of tumors, literature detailing the efficacy, safety and complication rates for the usage of Onyx is relatively sparse. Materials and Methods We reviewed our single institutional experience with pre-surgical Onyx embolization of extra-axial tumors to evaluate its efficacy and safety and highlight nuances of individualized cases. Results Five patients underwent pre-surgical Onyx embolization of large or giant extra-axial tumors within 24 hours of surgical resection. Four patients harbored falcine or convexity meningiomas (grade I in 2 patients, grade II in 1 patient and grade III in one patient), and one patient had a grade II hemangiopericytoma. Embolization proceeded uneventfully in all cases and there were no complications. Conclusion This series augments the expanding literature confirming the safety and efficacy of Onyx in the preoperative embolization of extra-axial tumors, underscoring its advantage of being able to attain extensive devascularization via only one supplying pedicle. PMID:27114961
Preoperative Embolization of Extra-axial Hypervascular Tumors with Onyx.
Fusco, Matthew R; Salem, Mohamed M; Gross, Bradley A; Reddy, Arra S; Ogilvy, Christopher S; Kasper, Ekkehard M; Thomas, Ajith J
2016-03-01
Preoperative endovascular embolization of intracranial tumors is performed to mitigate anticipated intraoperative blood loss. Although the usage of a wide array of embolic agents, particularly polyvinyl alcohol (PVA), has been described for a variety of tumors, literature detailing the efficacy, safety and complication rates for the usage of Onyx is relatively sparse. We reviewed our single institutional experience with pre-surgical Onyx embolization of extra-axial tumors to evaluate its efficacy and safety and highlight nuances of individualized cases. Five patients underwent pre-surgical Onyx embolization of large or giant extra-axial tumors within 24 hours of surgical resection. Four patients harbored falcine or convexity meningiomas (grade I in 2 patients, grade II in 1 patient and grade III in one patient), and one patient had a grade II hemangiopericytoma. Embolization proceeded uneventfully in all cases and there were no complications. This series augments the expanding literature confirming the safety and efficacy of Onyx in the preoperative embolization of extra-axial tumors, underscoring its advantage of being able to attain extensive devascularization via only one supplying pedicle.
Mazur, Marcus D; Ravindra, Vijay M; Dailey, Andrew T; McEvoy, Sara; Schmidt, Meic H
2015-01-01
Pelvic fixation with S2-alar-iliac (S2AI) screws can increase the rigidity of a lumbosacral construct, which may promote bone healing, improve antibiotic delivery to infected tissues, and avoid L5-S1 pseudarthrosis. To describe the use of single-stage posterior fixation without debridement for the treatment of pyogenic vertebral diskitis and osteomyelitis (PVDO) at the lumbosacral junction. Technical report. We describe the management of PVDO at the lumbosacral junction in which the infection invaded the endplates, disk space, vertebrae, prevertebral soft tissues, and epidural space. Pedicle involvement precluded screw fixation at L5. Surgical management consisted of a single-stage posterior operation with rigid lumbopelvic fixation augmented with S2-alar-iliac screws and without formal debridement of the infected area, followed by long-term antibiotic treatment. At 2-year follow-up, successful fusion and eradication of the infection were achieved. PVDO at the lumbosacral junction may be treated successfully using rigid posterior-only fixation without formal debridement combined with antibiotic therapy.
Zhang, Yu-peng; Shi, Ya-min; Wang, Hua-dong; Hou, Shu-xun
2015-10-01
To evaluate the accuracy and safety of pedicle screw insertion with the aid of novel patient-specific drill-guide templates in scoliosis cases. Ten patients with scoliosis were selected to participate in the research (the observation group) from December 2013 to December 2014. The data was obtained from CT scanning, and put into the computer to perform reconstruction of spine, simulation of pedicle screw insertion, and design of patient-specific drill-guide templates with software. The templates were made with rapid prototyping technique. After sterilization, the templates were used to aid the pedicle screw insertion intraoperatively. The blood loss, operation duration, change of creatinine level pre- and post-operation, and complications related to pedicle screw insertion were recorded. The location of pedicle screws were graded so as to evaluate the accuracy. A comparative study was then performed with the data of ten scoliosis cases operated with free-hand method during the same period (control group). There were 5 cases of idiopathic scoliosis and 5 cases of congenital scoliosis in the observation group, including 3 males and 7 females. Their average age was 11.9 years old (ranged, 4 to 18 years old), and the average Cobb angle of main curve was 54.9° (ranged, 42.1° to 78.4°). There were also 5 cases of idiopathic scoliosis and 5 cases of congenital scoliosis in the control group,including 2 males and 8 females. Their average age was 12.6 years old (ranged, 6 to 17 years old), and the average Cobb angle of main curve was 56.6° (ranged, 38.2° to 93.4°). A total of 167 pedicle screws were inserted intraoperatively, with 138 screws (82.6%) in grade I, 26 screws (15.0%) in grade II, 4 screws in grade III (2.4%), but no screws in grade IV according to the CT image. There were 29 (17.4%) screws perforated, and 163 (97.6%) screws could be accepted. In the control group, a total of 165 pedicle screws were inserted intraoperatively, with 98 screws (59.4%) in grade I, 39 screws (23.6%) in grade II, 21 screws in grade III (12.7%), and 7 screws in grade IV (4.2%). There were 67 (40.6%) screws perforated, and 137 (83.0%) screws could be accepted. The grade distribution of screw position, ratio of perforated and accepted screws were significantly different between the two groups respectively (Z=-5.013, P=0.000; χ2=9.347, P=0.002; χ2=20.242, P=0.000). The correction rate of Cobb angle were (74.1±10.0)% vs (69.7±17.6)%; blood loss were (455±447) ml vs (415±389) ml; operation duration were (163.5±53.7) min vs (164.0±48.7) min; and the changes of creatinine level pre- and post-operatively were (-5.3±3.2) μmol/L vs (-3.4±3.1) μmol/L; all above data had no significant differences respectively (t=0.696, P=0.496; t=0.214, P=0.833; t=0.022, P=0.983; t=1.375, P=0.192). There were no complications related to pedicle screw insertion in each group. The novel patient-specific drill guide template can be used to assist the insertion of pedicle screws in scoliosis cases with much higher accuracy than that of freehand method and fair safety.
Mohammed, Nasser; Patra, Devi Prasad; Narayan, Vinayak; Savardekar, Amey R; Dossani, Rimal Hanif; Bollam, Papireddy; Bir, Shyamal; Nanda, Anil
2018-01-01
OBJECTIVE Spondylosis with or without spondylolisthesis that does not respond to conservative management has an excellent outcome with direct pars interarticularis repair. Direct repair preserves the segmental spinal motion. A number of operative techniques for direct repair are practiced; however, the procedure of choice is not clearly defined. The present study aims to clarify the advantages and disadvantages of the different operative techniques and their outcomes. METHODS A meta-analysis was conducted in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. The following databases were searched: PubMed, Cochrane Library, Web of Science, and CINAHL ( Cumulative Index to Nursing and Allied Health Literature). Studies of patients with spondylolysis with or without low-grade spondylolisthesis who underwent direct repair were included. The patients were divided into 4 groups based on the operative technique used: the Buck repair group, Scott repair group, Morscher repair group, and pedicle screw-based repair group. The pooled data were analyzed using the DerSimonian and Laird random-effects model. Tests for bias and heterogeneity were performed. The I 2 statistic was calculated, and the results were analyzed. Statistical analysis was performed using StatsDirect version 2. RESULTS Forty-six studies consisting of 900 patients were included in the study. The majority of the patients were in their 2nd decade of life. The Buck group included 19 studies with 305 patients; the Scott group had 8 studies with 162 patients. The Morscher method included 5 studies with 193 patients, and the pedicle group included 14 studies with 240 patients. The overall pooled fusion, complication, and outcome rates were calculated. The pooled rates for fusion for the Buck, Scott, Morscher, and pedicle screw groups were 83.53%, 81.57%, 77.72%, and 90.21%, respectively. The pooled complication rates for the Buck, Scott, Morscher, and pedicle screw groups were 13.41%, 22.35%, 27.42%, and 12.8%, respectively, and the pooled positive outcome rates for the Buck, Scott, Morscher, and pedicle screw groups were 84.33%, 82.49%, 80.30%, and 80.1%, respectively. The pedicle group had the best fusion rate and lowest complication rate. CONCLUSIONS The pedicle screw-based direct pars repair for spondylolysis and low-grade spondylolisthesis is the best choice of procedure, with the highest fusion and lowest complication rates, followed by the Buck repair. The Morscher and Scott repairs were associated with a high rate of complication and lower rates of fusion.
Hayes, Katherine L; Messina, Louis M; Schwartz, Lawrence M; Yan, Jinglian; Burnside, Amy S; Witkowski, Sarah
2018-05-01
Peripheral artery disease is an atherosclerotic occlusive disease that causes limb ischemia and has few effective noninterventional treatments. Stem cell therapy is promising, but concomitant diabetes may limit its effectiveness. We evaluated the therapeutic potential of skeletal muscle pericytes to augment postischemic neovascularization in wild-type and type 2 diabetic (T2DM) mice. Wild-type C57BL/6J and leptin receptor spontaneous mutation db/db T2DM mice underwent unilateral femoral artery excision to induce limb ischemia. Twenty-four hours after ischemia induction, CD45 - CD34 - CD146 + skeletal muscle pericytes or vehicle controls were transplanted into ischemic hindlimb muscles. At postoperative day 28, pericyte transplantation augmented blood flow recovery in wild-type mice (79.3 ± 5% vs. 61.9 ± 5%; P = 0.04), but not in T2DM mice (48.6% vs. 46.3 ± 5%; P = 0.51). Pericyte transplantation augmented collateral artery enlargement in wild-type (26.7 ± 2 μm vs. 22.3 ± 1 μm, P = 0.03), but not T2DM mice (20.4 ± 1.4 μm vs. 18.5 ± 1.2 μm, P = 0.14). Pericyte incorporation into collateral arteries was higher in wild-type than in T2DM mice ( P = 0.002). Unexpectedly, pericytes differentiated into Schwann cells in vivo. In vitro, Insulin increased Nox2 expression and decreased tubular formation capacity in human pericytes. These insulin-induced effects were reversed by N-acetylcysteine antioxidant treatment. In conclusion, T2DM impairs the ability of pericytes to augment neovascularization via decreased collateral artery enlargement and impaired engraftment into collateral arteries, potentially via hyperinsulinemia-induced oxidant stress. While pericytes show promise as a unique form of stem cell therapy to increase postischemic neovascularization, characterizing the molecular mechanisms by which T2DM impairs their function is essential to achieve their therapeutic potential.
Correction of cryptotia using a subcutaneous pedicled flap.
Nakajima, T; Yoneda, K; Yoshimura, Y
1991-01-01
Cryptotia is a relatively common deformity of the ear among orientals. Although many methods for correcting this deformity have been reported, there is no one perfect method. We have developed a method using a subcutaneous pedicle flap raised from the retroauricular region, where relative abundance of skin exists. We have treated 9 ears of 7 patients by the method reported herein. Results are satisfactory in all cases.
Albert, Michael C; LaFleur, Brett C
2015-03-01
Segmental spinal instrumentation with Luque wire fixation has been the standard treatment of neuromuscular scoliosis for >30 years. More recently, pedicle screw constructs have become the most widely utilized method of posterior spinal fixation; however, they are associated with complications such as implant malposition. We report the use of polyester bands and clamps utilized with pedicle screws in a hybrid fixation construct in the treatment of neuromuscular scoliosis. A retrospective review was conducted of 115 pediatric spinal deformity cases between 2008 and 2010 at a single center performed by a single surgeon. Intraoperative and postoperative complications were recorded. Radiographs were reviewed preoperatively and at the latest follow-up. A systematic review of the literature was conducted. Data from case series reporting outcomes of sublaminar wires and all-pedicle screw constructs in the treatment of neuromuscular scoliosis were compared with outcomes of the present study. Twenty-nine patients with neuromuscular scoliosis who underwent segmental spinal instrumentation with a hybrid construct including sublaminar bands and pedicle screws were included. There was an average follow-up of 29 months (range, 12 to 40 mo). The average postoperative correction of coronal balance was 69% (range, 24 to 71 degrees). Sagittal balance was corrected to within 2 cm of the C7 plumbline in 97% of patients. The loss of coronal and sagittal correction at latest follow-up was 0% and 2%, respectively. There were 2 intraoperative clamp failures of the 398 implants (0.5%). There were 2 major (6.9%) and 7 minor (24%) complications in 7 patients (24% overall). These results compared favorably to previous case series of sublaminar wire and all-pedicle screw fixation techniques. The polyester band technique is an excellent adjunct in the correction of spinal deformity in patients with neuromuscular scoliosis. Sublaminar bands utilized in a hybrid construct appear to be safe, can achieve corrections equivalent to all-pedicle screw constructs, and may decrease the potential complications associated with every level transpedicular fixation in the patient with a highly dysmorphic and osteoporotic spine. Level IV: cohort study.
Ikeuchi, Hiroko; Ikuta, Ko
2016-09-01
In the last decade, posterior instrumented fusion using percutaneous pedicle screws (PPSs) had been growing in popularity, and its safety and good clinical results have been reported. However, there have been few previous reports of the accuracy of PPS placement compared with that of conventional open screw insertion in an institution. This study aimed to evaluate the accuracy of PPS placement compared with that of conventional open technique. One hundred patients were treated with posterior instrumented fusion of the thoracic and lumbar spine from April 2008 to July 2013. Four cases of revised instrumentation surgery were excluded. In this study, the pedicle screws inserted below Th7 were investigated, therefore, a total of 455 screws were enrolled. Two hundred and ninety-three pedicle screws were conventional open-inserted screws (O-group) and 162 screws were PPSs (P-group). We conducted a comparative study about the accuracy of placement between the two groups. Postoperative computed tomography scans were carried out to all patients, and the pedicle screw position was assessed according to a scoring system described by Zdichavsky et al. (Eur J Trauma 30:241-247, 2004; Eur J Trauma 30:234-240, 2004) and a classification described by Wiesner et al. (Spine 24:1599-1603, 1999). Based on Zdichavsky's scoring system, the number of grade Ia screws was 283 (96.6 %) in the O-group and 153 (94.4 %) in the P-group, whereas 5 screws (1.7 %) in the O-group and one screw (0.6 %) in the P-group were grade IIIa/IIIb. Meanwhile, the pedicle wall penetrations based on Wiesner classification were demonstrated in 20 screws (6.8 %) in the O-group, and 12 screws (7.4 %) in the P-group. No neurologic complications were observed and no screws had to be replaced in both groups. The PPSs could be ideally inserted without complications. There were no statistically significant differences about the accuracy between the conventional open insertion and PPS placement.
Known-component 3D-2D registration for quality assurance of spine surgery pedicle screw placement
NASA Astrophysics Data System (ADS)
Uneri, A.; De Silva, T.; Stayman, J. W.; Kleinszig, G.; Vogt, S.; Khanna, A. J.; Gokaslan, Z. L.; Wolinsky, J.-P.; Siewerdsen, J. H.
2015-10-01
A 3D-2D image registration method is presented that exploits knowledge of interventional devices (e.g. K-wires or spine screws—referred to as ‘known components’) to extend the functionality of intraoperative radiography/fluoroscopy by providing quantitative measurement and quality assurance (QA) of the surgical product. The known-component registration (KC-Reg) algorithm uses robust 3D-2D registration combined with 3D component models of surgical devices known to be present in intraoperative 2D radiographs. Component models were investigated that vary in fidelity from simple parametric models (e.g. approximation of a screw as a simple cylinder, referred to as ‘parametrically-known’ component [pKC] registration) to precise models based on device-specific CAD drawings (referred to as ‘exactly-known’ component [eKC] registration). 3D-2D registration from three intraoperative radiographs was solved using the covariance matrix adaptation evolution strategy (CMA-ES) to maximize image-gradient similarity, relating device placement relative to 3D preoperative CT of the patient. Spine phantom and cadaver studies were conducted to evaluate registration accuracy and demonstrate QA of the surgical product by verification of the type of devices delivered and conformance within the ‘acceptance window’ of the spinal pedicle. Pedicle screws were successfully registered to radiographs acquired from a mobile C-arm, providing TRE 1-4 mm and <5° using simple parametric (pKC) models, further improved to <1 mm and <1° using eKC registration. Using advanced pKC models, screws that did not match the device models specified in the surgical plan were detected with an accuracy of >99%. Visualization of registered devices relative to surgical planning and the pedicle acceptance window provided potentially valuable QA of the surgical product and reliable detection of pedicle screw breach. 3D-2D registration combined with 3D models of known surgical devices offers a novel method for intraoperative QA. The method provides a near-real-time independent check against pedicle breach, facilitating revision within the same procedure if necessary and providing more rigorous verification of the surgical product.
Abrupt increase in rat carotid blood flow induces rapid alteration of artery mechanical properties
Monson, Kenneth L.; Matsumoto, Melissa M.; Young, William L.; Manley, Geoffrey T.; Hashimoto, Tomoki
2010-01-01
Vascular remodeling is essential to proper vessel function. Dramatic changes in mechanical environment, however, may initiate pathophysiological vascular remodeling processes that lead to vascular disease. Previous work by some of our group has demonstrated a dramatic rise in matrix metalloproteinase (MMP) expression shortly following an abrupt increase in carotid blood flow. We hypothesized that there would be a corresponding change in carotid mechanical properties. Unilateral carotid ligation surgery was performed to produce an abrupt, sustained increase in blood flow through the contralateral carotid artery of rats. The flow-augmented artery was harvested after sham surgery or 1, 2, or 6 days after flow augmentation. Vessel mechanical response in the circumferential direction was then evaluated through a series of pressure-diameter tests. Results show that the extent of circumferential stretch (normalized change in diameter) at in vivo pressure levels was significantly different (p<0.05) from normo-flow controls at 1 and 2 days following flow augmentation. Measurements at 1, 2, and 6 days were not significantly different from one another, but a trend in the data suggested that circumferential stretch was largest 1 day following surgery and subsequently decreased toward baseline values. Because previous work with this model indicated a similar temporal pattern for MMP-9 expression, an exploratory set of experiments was conducted where vessels were tested 1 day following surgery in animals treated with broad spectrum MMP inhibitors (either doxycycline or GM6001). Results showed a trend for the inhibitors to minimize changes in mechanical properties. Observations demonstrate that vessel mechanical properties change rapidly following flow augmentation and that alterations may be linked to expression of MMPs. PMID:21094476
The Interaction of Fatigue and Potentiation Following an Acute Bout of Unilateral Squats
Andrews, Samantha K.; Horodyski, Jesse M.; MacLeod, Daniel A.; Whitten, Joseph; Behm, David G.
2016-01-01
A prior conditioning resistance exercise can augment subsequent performance of the affected muscles due to the effects of post-activation potentiation (PAP). The non-local muscle fatigue literature has illustrated the global neural effects of unilateral fatigue. However, no studies have examined the possibility of acute non-local performance enhancements. The objective of the study was to provide a conditioning stimulus in an attempt to potentiate the subsequent jump performance of the affected limb and determine if there were performance changes in the contralateral limb. Using a randomized allocation, 14 subjects (6 females, 8 males) completed three conditions on separate days: 1) unilateral, dominant leg, Bulgarian split squat protocol with testing of the exercised leg, 2) unilateral, dominant leg, Bulgarian split squat protocol with testing of the contralateral, non-exercised leg and 3) control session with testing of the non-dominant leg. Pre- and post-testing consisted of countermovement (CMJ) and drop jumps (DJ). The exercised leg exhibited CMJ height increases of 3.5% (p = 0.008; d = 0.28), 4.0% (p = 0.011; d = 0.33) and 3.2% (p = 0.013; d = 0.26) at 1, 5, and 10 min post-intervention respectively. The contralateral CMJ height had 2.0% (p = 0.034; d = 0.18), 1.2% (p = 0.2; d = 0.12), and 2.1% (p = 0.05; d = 0.17) deficits at 1, 5, and 10 min post-intervention respectively. Similar relative results were found for CMJ power. There were no significant interactions for DJ measures or control CMJ measures. The findings suggest that PAP effects were likely predominant for the exercised leg whereas the conditioning exercise provided trivial magnitude although statistically significant neural impairments for the contralateral limb. Key points Post-activation potentiation of unilateral CMJ height was achieved following 5 sequential squats at 50% 1RM, 2 squats at 70% 1RM, 1 squat at 90% 1RM with 3 min rest periods. The conditioning exercises did not elicit significant drop jump improvements, likely due to balance challenges. In contrast to the potentiation of the affected leg, there were statistically significant impairments of contralateral CMJ height suggesting the co-existence of post-activation potentiation (affected limb) and crossover neural fatigue. PMID:27928208
Zhang, Qixu; Hubenak, Justin; Iyyanki, Tejaswi; Alred, Erik; Turza, Kristin C.; Davis, Greg; Chang, Edward I.; Branch-Brooks, Cynthia D.; Beahm, Elisabeth K.; Butler, Charles E.
2015-01-01
Insufficient neovascularization is associated with high levels of resorption and necrosis in autologous and engineered fat grafts. We tested the hypothesis that incorporating angiogenic growth factor into a scaffold–stem cell construct and implanting this construct around a vascular pedicle improves neovascularization and adipogenesis for engineering soft tissue flaps. Poly(lactic-co-glycolic-acid/polyethylene glycol (PLGA/PEG) microspheres containing vascular endothelial growth factor (VEGF) were impregnated into collagen-chitosan scaffolds seeded with human adipose-derived stem cells (hASCs). This setup was analyzed in vitro and then implanted into isolated chambers around a discrete vascular pedicle in nude rats. Engineered tissue samples within the chambers were harvested and analyzed for differences in vascularization and adipose tissue growth. In vitro testing showed that the collagen-chitosan scaffold provided a supportive environment for hASC integration and proliferation. PLGA/PEG microspheres with slow-release VEGF had no negative effect on cell survival in collagen-chitosan scaffolds. In vivo, the system resulted in a statistically significant increase in neovascularization that in turn led to a significant increase in adipose tissue persistence after 8 weeks versus control constructs. These data indicate that our model—hASCs integrated with a collagen-chitosan scaffold incorporated with VEGF-containing PLGA/PEG microspheres supported by a predominant vascular vessel inside a chamber—provides a promising, clinically translatable platform for engineering vascularized soft tissue flap. The engineered adipose tissue with a vascular pedicle could conceivably be transferred as a vascularized soft tissue pedicle flap or free flap to a recipient site for the repair of soft-tissue defects. PMID:26410787
Wangdi, Kuenzang; Otsuki, Bungo; Fujibayashi, Shunsuke; Tanida, Shimei; Masamoto, Kazutaka; Matsuda, Shuichi
2018-02-07
To report on suggested technique with four screws in a single vertebra (two pedicle screws and two direct vertebral body screws) for enhanced fixation with just one level cranially to a pedicle subtraction osteotomy (PSO). A 60-year-old woman underwent L4/5 fusion surgery for degenerative spondylolisthesis. Two years later, she was unable to stand upright even for a short time because of lumbar kyphosis caused by subsidence of the fusion cage and of Baastrup syndrome in the upper lumbar spine [sagittal vertical axis (SVA) of 114 mm, pelvic incidence of 75°, and lumbar lordosis (LL) of 41°]. She underwent short-segment fusion from L4 to the sacrum with L5 pedicle subtraction osteotomy. We reinforced the construct with two vertebral screws at L4 in addition to the conventional L4 pedicle screws. After the surgery, her sagittal parameters were improved (SVA, 36 mm; LL, 54°). Two years after the corrective surgery, she maintained a low sagittal vertical axis though high residual pelvic tilt indicated that the patient was still compensating for residual sagittal misalignment. PSO surgery for sagittal imbalance usually requires a long fusion at least two levels above and below the osteotomy site to achieve adequate stability and better global alignment. However, longer fixation may decrease the patients' quality of life and cause a proximal junctional failure. Our novel technique may shorten the fixation area after osteotomy surgery. These slides can be retrieved under Electronic Supplementary Material.
Freeman, Andrew L; Fahim, Mina S; Bechtold, Joan E
2012-10-01
Previous methods of pedicle screw strain measurement have utilized complex, time consuming methods of strain gauge application, experience high failure rates, do not effectively measure resultant bending moments, and cannot predict moment orientation. The purpose of this biomechanical study was to validate an improved method of quantifying pedicle screw bending moment orientation and magnitude. Pedicle screws were instrumented to measure biplanar screw bending moments by positioning four strain gauges on flat, machined surfaces below the screw head. Screws were calibrated to measure bending moments by hanging certified weights a known distance from the strain gauges. Loads were applied in 30 deg increments at 12 different angles while recording data from two independent strain channels. The data were then analyzed to calculate the predicted orientation and magnitude of the resultant bending moment. Finally, flexibility tests were performed on a cadaveric motion segment implanted with the instrumented screws to demonstrate the implementation of this technique. The difference between the applied and calculated orientation of the bending moments averaged (±standard error of the mean (SEM)) 0.3 ± 0.1 deg across the four screws for all rotations and loading conditions. The calculated resultant bending moments deviated from the actual magnitudes by an average of 0.00 ± 0.00 Nm for all loading conditions. During cadaveric testing, the bending moment orientations were medial/lateral in flexion-extension, variable in lateral bending, and diagonal in axial torsion. The technique developed in this study provides an accurate method of calculating the orientation and magnitude of screw bending moments and can be utilized with any pedicle screw fixation system.
NASA Astrophysics Data System (ADS)
Wang, Tianyuan; Ishihara, Takeaki; Kono, Atsushi; Yoshida, Naoki; Akasaka, Hiroaki; Mukumoto, Naritoshi; Yada, Ryuichi; Ejima, Yasuo; Yoshida, Kenji; Miyawaki, Daisuke; Kakutani, Kenichiro; Nishida, Kotaro; Negi, Noriyuki; Minami, Toshiaki; Aoyama, Yuuichi; Takahashi, Satoru; Sasaki, Ryohei
2017-08-01
The objective of the present study was the determination of the potential dosimetric benefits of using metal-artefact-suppressed dual-energy computed tomography (DECT) images for cases involving pedicle screw implants in spinal sites. A heterogeneous spinal phantom was designed for the investigation of the dosimetric effect of the pedicle-screw-related artefacts. The dosimetric comparisons were first performed using a conventional two-directional opposed (AP-PA) plan, and then a volumetric modulated arc therapy (VMAT) plan, which are both used for the treatment of spinal metastases in our institution. The results of Acuros® XB dose-to-medium (Dm) and dose-to-water (Dw) calculations using different imaging options were compared with experimental measurements including the chamber and film dosimetries in the spinal phantom. A dual-energy composition image with a weight factor of -0.2 and a dual-energy monochromatic image (DEMI) with an energy level of 180 keV were found to have superior abilities for artefact suppression. The Dm calculations revealed greater dosimetric effects of the pedicle screw-related artefacts compared to the Dw calculations. The results of conventional single-energy computed tomography showed that, although the pedicle screws were made from low-Z titanium alloy, the metal artefacts still have dosimetric effects, namely, an average (maximum) Dm error of 4.4% (5.6%) inside the spinal cord for a complex VMAT treatment plan. Our findings indicate that metal-artefact suppression using the proposed DECT (DEMI) approach is promising for improving the dosimetric accuracy near the implants and inside the spinal cord (average (maximum) Dm error of 1.1% (2.0%)).
Zhang, Qixu; Hubenak, Justin; Iyyanki, Tejaswi; Alred, Erik; Turza, Kristin C; Davis, Greg; Chang, Edward I; Branch-Brooks, Cynthia D; Beahm, Elisabeth K; Butler, Charles E
2015-12-01
Insufficient neovascularization is associated with high levels of resorption and necrosis in autologous and engineered fat grafts. We tested the hypothesis that incorporating angiogenic growth factor into a scaffold-stem cell construct and implanting this construct around a vascular pedicle improves neovascularization and adipogenesis for engineering soft tissue flaps. Poly(lactic-co-glycolic-acid/polyethylene glycol (PLGA/PEG) microspheres containing vascular endothelial growth factor (VEGF) were impregnated into collagen-chitosan scaffolds seeded with human adipose-derived stem cells (hASCs). This setup was analyzed in vitro and then implanted into isolated chambers around a discrete vascular pedicle in nude rats. Engineered tissue samples within the chambers were harvested and analyzed for differences in vascularization and adipose tissue growth. In vitro testing showed that the collagen-chitosan scaffold provided a supportive environment for hASC integration and proliferation. PLGA/PEG microspheres with slow-release VEGF had no negative effect on cell survival in collagen-chitosan scaffolds. In vivo, the system resulted in a statistically significant increase in neovascularization that in turn led to a significant increase in adipose tissue persistence after 8 weeks versus control constructs. These data indicate that our model-hASCs integrated with a collagen-chitosan scaffold incorporated with VEGF-containing PLGA/PEG microspheres supported by a predominant vascular vessel inside a chamber-provides a promising, clinically translatable platform for engineering vascularized soft tissue flap. The engineered adipose tissue with a vascular pedicle could conceivably be transferred as a vascularized soft tissue pedicle flap or free flap to a recipient site for the repair of soft-tissue defects. Copyright © 2015 Elsevier Ltd. All rights reserved.
Hou, Yang; Shi, Jiangang; Lin, Yanping; Chen, Huajiang; Yuan, Wen
2018-06-01
The cervical screw placement is one of the most difficult procedures in spine surgery, which often needs a long period of repeated practices and could cause screw placement-related complications. We performed this cadaver study to investigate the effectiveness of virtual surgical training system (VSTS) on cervical pedicle screw instrumentation for residents. A total of ten novice residents were randomly assigned to two groups: the simulation training (ST) group (n = 5) and control group (n = 5). The ST group received a surgical training of cervical pedicle screw placement on VSTS and the control group was given an introductory teaching session before cadaver test. Ten fresh adult spine specimens including 6 males and 4 females were collected, and were randomly allocated to the two groups. The bilateral C3-C6 pedicle screw instrumentation was performed in the specimens of the two groups, respectively. After instrumentation, screw positions of the two groups were evaluated by image examinations. There was significantly statistical difference in screw penetration rates between the ST (10%) and control group (62.5%, P < 0.05). The acceptable rates of screws were 100 and 50% in the ST and control groups with significant difference between each other (P < 0.05). In addition, the average screw penetration distance in the ST group (1.12 ± 0.47 mm) was significantly lower than the control group (2.08 ± 0.39 mm, P < 0.05). This study demonstrated that the VSTS as an advanced training tool exhibited promising effects on improving performance of novice residents in cervical pedicle screw placement compared with the traditional teaching methods.
Unskilled unawareness and the learning curve in robotic spine surgery.
Schatlo, Bawarjan; Martinez, Ramon; Alaid, Awad; von Eckardstein, Kajetan; Akhavan-Sigari, Reza; Hahn, Anina; Stockhammer, Florian; Rohde, Veit
2015-10-01
Robotic assistance for the placement of pedicle screws has been established as a safe technique. Nonetheless rare instances of screw misplacement have been reported.The aim of the present retrospective study is to assess whether experience and time affect the accuracy of screws placed with the help of the SpineAssist™ robot system. Postoperative computed tomography (CT) scans of 258 patients requiring thoracolumbar pedicle screw instrumentation from 2008 to 2013 were reviewed. Overall, 13 surgeons performed the surgeries. A pedicle breach of >3 mm was graded as a misplacement. Surgeons were dichotomised into an early and experienced period in increments of five surgeries. In 258 surgeries, 1,265 pedicle screws were placed with the aid of the robot system. Overall, 1,217 screws (96.2 %) were graded as acceptable. When displayed by surgeon, the development of percent misplacement rates peaked between 5 and 25 surgeries in 12 of 13 surgeons. The overall misplacement rate in the first five surgeries was 2.4 % (6/245). The misplacement rate rose to 6.3 % between 11 and 15 surgeries (10/158; p = 0.20), and reached a significant peak between 16 and 20 surgeries with a rate of 7.1 % (8/112; p = 0.03). Afterwards, misplacement rates declined. A major peak in screw inaccuracies occurred between cases 10 and 20, and a second, smaller one at about 40 surgeries. One potential explanation could be a transition from decreased supervision (unskilled but aware) to increased confidence of a surgeon (unskilled but unaware) who adopts this new technique prior to mastering it (skilled). We therefore advocate ensuring competent supervision for new surgeons at least during the first 25 procedures of robotic spine surgery to optimise the accuracy of robot-assisted pedicle screws.
Wang, Yang; Qian, Bangping; Li, Baoxin; Qin, Guochu; Zhou, Zhengyang; Qiu, Yong; Sun, Xizhao; Zhu, Bin
2013-08-01
To evaluate the effectiveness of spectral CT in reducing metal artifacts caused by pedicle screws in patients with scoliosis. Institutional review committee approval and written informed consents from patients were obtained. 18 scoliotic patients with a total of 228 pedicle screws who underwent spectral CT imaging were included in this study. Monochromatic image sets with and without the additional metal artifacts reduction software (MARS) correction were generated with photon energy at 65keV and from 70 to 140keV with 10keV interval using the 80kVp and 140kVp projection sets. Polychromatic images corresponded to the conventional 140kVp imaging were also generated from the same scan data as a control group. Both objective evaluation (screw width and quantitative artifacts index measurements) and subjective evaluation (depiction of pedicle screws, surrounding structures and their relationship) were performed. Image quality of monochromatic images in the range from 110 to 140keV (0.97±0.28) was rated superior to the conventional polychromatic images (2.53±0.54) and also better than monochromatic images with lower energy. Images of energy above 100keV also give accurate measurement of the width of screws and relatively low artifacts index. The form of screws was slightly distorted in MARS reconstruction. Compared to conventional polychromatic images, monochromatic images acquired from dual-energy CT provided superior image quality with much reduced metal artifacts of pedicle screws in patients with scoliosis. Optimal energy range was found between 110 and 140keV. Crown Copyright © 2013. Published by Elsevier Ireland Ltd. All rights reserved.
Xu, Yue-Min; Sa, Ying-Long; Fu, Qiang; Zhang, Jiong; Xie, Hong; Jin, San-Bao
2009-07-01
Female urethral injury is rare, and there is no accepted standard approach for the repair of urethral strictures. To evaluate the efficacy of transpubic access using pedicle tubularized labial urethroplasty for urethral reconstruction in female patients with urethral obliterative strictures and urethrovaginal fistulas. Between January 1996 and December 2006, eight cases of female urethral strictures associated with urethrovaginal fistulas were treated using pedicle labial skin flaps. A flap of approximately 3x3.5x3cm of the labia minora or majora with its vascular pedicle was tubularized over an 18-22 Fr fenestrated silicone stent to create a neourethra. This technique was used in five women. Two flaps, approximately 1.5-3.5 cm, were taken from bilateral labia minora or majora and were pieced together to create a neourethra. This technique was used in three patients. We performed voiding cystourethrography and uroflowmetry to assess postoperative results. The patients were followed up for 10-118 mo (mean 48.25 mo) after the procedure. There were no postoperative complications. Two patients complained of dysuria, which resolved spontaneously after 2 wk. One patient experienced stress incontinence that resolved after 4 wk. At 3-mo follow-up, one patient complained of difficulty voiding; the urinary peak flow was 13 ml/s, and the patient was treated successfully with urethral dilation. All other patients had normal micturition following catheter removal. Pedicle labial urethroplasty is a reliable technique for the repair of extensive urethral damage, and a transpubic surgical approach provides wide and excellent exposure for the management of complex obliterative urethral strictures and urethrovaginal fistulas secondary to pelvic fracture.
Yasuda, Atsushi; Yasuda, Takushi; Kato, Hiroaki; Iwama, Mitsuru; Shiraishi, Osamu; Hiraki, Yoko; Tanaka, Yumiko; Shinkai, Masayuki; Imano, Motohiro; Kimura, Yutaka; Imamoto, Haruhiko
2017-12-01
An incisional hernia in a case of antethoracic pedicled jejunal flap esophageal reconstruction after esophagectomy is a very rare occurrence, and this hernia was distinctive in that the reconstructed jejunum had passed through the hernial orifice; a standard surgical treatment for such a presentation has not been established. Herein, we describe a case of repair using mesh prosthesis for an atypical and distinctive incisional hernia after antethoracic pedicled jejunal flap esophageal reconstruction. A 77-year-old woman with a history of subtotal esophagectomy who had undergone antethoracic pedicled jejunal flap reconstruction complained of epigastric prominence and discomfort without pain. On examination, she had an abdominal protrusion between the xiphoid process and the umbilicus that contained the small bowel. Computed tomography showed that the fenestration of the abdominal wall that was intentionally created for jejunum pull-up was dehisced in a region measuring 9 × 15 cm and the small intestine protruded through it into the subcutaneous space without strangulation. Because the hernial orifice was too large and the reconstructed jejunum was passing through the hernial orifice in this case, we applied a parastomal hernia repair method that was modified from the inguinal hernia repair using the Lichtenstein technique. After 3 years and 5 months following surgery, the patient has recovered without hernia recurrence or other complications. We consider this to be the first case of repair using Composix mesh prosthesis for repair of an atypical and distinctive incisional hernia after an antethoracic pedicled jejunal flap reconstruction. This method seems to be useful and could potentially be widely adopted as the surgical treatment for this condition.
Wang, Xiaoyu; Aubin, Carl-Eric; Coleman, John; Rawlinson, Jeremy
2017-05-01
Computer simulations to compare the correction capabilities of different pedicle screws in adolescent idiopathic scoliosis (AIS) instrumentations. To compare the correction and resulting bone-screw forces associated with different pedicle screws in scoliosis instrumentations. Pedicle screw fixation is widely used in surgical instrumentation for spinal deformity treatment. Screw design, correction philosophies, and surgical techniques are constantly evolving to achieve better control of the vertebrae and correction of the spinal deformity. Yet, there remains a lack of biomechanical studies that quantify the effects and advantages of different screw designs in terms of correction kinematics. The correction capabilities of fixed-angle, multiaxial, uniaxial, and saddle axial screws were kinematically analyzed, simulated, and compared. These simulations were based on the screw patterns and correction techniques proposed by 2 experienced surgeons for 2 AIS cases. Additional instrumentations were assessed to compare the correction and resulting bone-screw forces associated with each type of screw. The fixed-angle, uniaxial and saddle axial screws had similar kinematic behavior and performed better than multiaxial screws in the coronal and transverse planes (8% and 30% greater simulated corrections, respectively). Uniaxial and multiaxial screws were less effective than fixed-angle and saddle axial screws in transmitting compression/distraction to the anterior spine because of their sagittal plane mobility between the screw head and shank. Only the saddle axial screws allow vertebra angle in the sagittal plane to be independently adjusted. Pedicle screws of different designs performed differently for deformity corrections or for compensating screw placement variations in different anatomic planes. For a given AIS case, screw types should be determined based on the particular instrumentation objectives, the deformity's stiffness and characteristics so as to make the best of the screw designs.
Papadakis, Marios; Rahmanian-Schwarz, Afshin; Bednarek, Marzena; Arafkas, Mohamed; Holschneider, Philipp; Hübner, Gunnar
2017-05-15
Accidental extravasation is a serious iatrogenic injury among patients receiving anthracycline-containing chemotherapy. The aim of this work is to present a combination therapy for chest wall reconstruction following epirubicin extravasation. Herein, we report a 68-year-old woman with massive soft tissue necrosis of the anterolateral chest wall after epirubicin extravasation from a port implanted in the subclavicular area. The necrotic tissue was resected, the port was removed, and negative-pressure wound therapy was applied. Three weeks later, a latissimus dorsi pedicle flap was successfully used to cover the defect. To the best of the authors' knowledge, this is the first report of a strategy comprising the combination of negative-pressure wound therapy and a latissimus pedicle flap for reconstruction of the chest wall after soft tissue necrosis following epirubicin extravasation.
Álvarez Postigo, M; Pizones Arce, J; Izquierdo Núñez, E
Posterior lumbar screw fixation is a common surgical procedure nowadays. However, it can sometimes produce complications that can be devastating. One of the less common causes of major complication is the misplacement of a pedicle screw. This highlights the importance of being methodical when placing pedicle screws, and checking that the pathway has been created correctly and their placement. We present a case of a massive bleed after a pedicular screw placement during lumbar canal stenosis surgery. Screw malposition led to intraoperative haemodynamic instability after failed attempts to control bleeding in the surgical site. Contrast enhanced CT imaging revealed a lumbar intersegmentary artery injury that was eventually controlled by means of a coil embolisation. Copyright © 2017 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.
[Clinical experience with the supraclavicular flap to reconstruct head and neck defects].
Zhang, Bin; Yan, Dangui; Zhang, Yabing; Zhang, Xiwei; Wan, Hanfeng
2015-06-01
To evaluate the efficacy of pedicled supraclavicular artery island flaps for head and neck reconstruction. Reconstructive surgeries for head and neck oncologic defects were performed with the pedicled supraclavicular artery island flaps in 10 patients from May 2013 to December 2014 and the cases were review. Among them, 6 were performed for hypopharyngeal cancer, 2 for oral tongue cancer, 1 for oral base cancer and 1 for cervical esophageal cancer. The size of the flaps was measured in (5-8) cm × (6-12) cm. Seven flaps survived, one flap failured and two flaps had partial necrosis. Donor sites were closed primarily without morbidity. The pedicled supraclavicular artery island flap is an easy harvesting and reliable for head and neck reconstruction, especially suitable for otolaryngo-head and neck surgeon and maxillofacial surgeon in the local hospital.
[Plastic Reconstruction with a Vascular Pedicle Latissimus Dorsi Flap after Sternal Osteomyelitis].
Spindler, N; Langer, S
2017-10-01
Objective: Sternal bone and soft tissue debridement after osteomyelitis of the sternum with simultaneous defect coverage using a vascular pedicle latissimus dorsi flap. Indication: Profound sternal wound healing disorders may be covered with various flap grafts. The latissimus dorsi flap provides a fast, sufficient and reliable option to cover sternal defects. If the bone and soft tissue debridement has been very radical, coverage may be performed in a one-stage procedure. Method: The individual surgical steps for sternal debridement with simultaneous defect coverage using a vascular pedicle latissimus dorsi flap are shown. Conclusion: The radicality of debridement is crucial to treatment success and allows debridement and flap graft coverage to be performed at the same time. If two surgeons work simultaneously, the duration of surgery may be significantly reduced. Georg Thieme Verlag KG Stuttgart · New York.
Innovative use of laterally positioned periosteal pedicle graft for coverage of gingivitis artefacta
Mechery, Reenesh; Harshavardhana, Babu; Rath, Saroj Kumar; Dinakar, Nithya
2016-01-01
There are many etiological factors for nonplaque-induced gingival diseases, out of which physical trauma due to psychiatric reasons leading to self-infliction is less studied upon. This case report presents one such case which has been successfully treated stepwise where psychological counseling was done to restrain from habit followed by using an innovative laterally positioned periosteal pedicle graft for dehiscence coverage. PMID:29238148
Beustes-Stefanelli, Matthieu; O'Toole, Greg; Schertenleib, Pierre
2016-01-01
In reconstructing anterior defects of the ear, postauricular flaps represent a popular option. The pedicle of such transauricular flaps can be superior, inferior, medial, or lateral. The postauricular helix-based adipodermal-pedicle turnover (PHAT) flap is an original single-stage transauricular technique for defects of the antihelix and scapha. Its skin paddle is on the posterior aspect of the ear. Its lateral de-epithelialized pedicle in front of the helix allows for it to easily reach peripheral anterior defects. In cases in which the underlying cartilage is involved, the extended PHAT (ePHAT) flap allows for restoring the contours of the ear without a cartilage graft. Between 2009 and 2011, a PHAT flap was used in 5 cases of defects of the antihelix or the scapha after tumor resection, 3 of which are in an extended version (ePHAT flap). There were no complications and a satisfactory aesthetic result was achieved in all cases. The PHAT flap is an original single-stage procedure for anterior auricular defects located on the antihelix or scapha. The single-layer PHAT flap is indicated in purely skin defect. The triple-layer ePHAT flap includes two subcutaneous extensions which increase its thickness and is indicated to restore the ear contours when cartilage has been removed.
Chitale, Rohan; Ghobrial, George M; Lobel, Darlene; Harrop, James
2013-10-01
The learning and development of technical skills are paramount for neurosurgical trainees. External influences and a need for maximizing efficiency and proficiency have encouraged advancements in simulator-based learning models. To confirm the importance of establishing an educational curriculum for teaching minimally invasive techniques of pedicle screw placement using a computer-enhanced physical model of percutaneous pedicle screw placement with simultaneous didactic and technical components. A 2-hour educational curriculum was created to educate neurosurgical residents on anatomy, pathophysiology, and technical aspects associated with image-guided pedicle screw placement. Predidactic and postdidactic practical and written scores were analyzed and compared. Scores were calculated for each participant on the basis of the optimal pedicle screw starting point and trajectory for both fluoroscopy and computed tomographic navigation. Eight trainees participated in this module. Average mean scores on the written didactic test improved from 78% to 100%. The technical component scores for fluoroscopic guidance improved from 58.8 to 52.9. Technical score for computed tomography-navigated guidance also improved from 28.3 to 26.6. Didactic and technical quantitative scores with a simulator-based educational curriculum improved objectively measured resident performance. A minimally invasive spine simulation model and curriculum may serve a valuable function in the education of neurosurgical residents and outcomes for patients.
Wright, Thomas C; Mossaad, Bassem M; Chummun, Shaheel; Khan, Umraz; Chapman, Thomas W L
2013-07-01
The proximally pedicled medial plantar flap is well described for coverage of wounds around the ankle and heel. This flap is usually based on the deep venae comitantes for venous drainage, with the superficial veins divided during dissection. Usually any disruption of the deep venous system of the flap would result in abandoning this choice of flap. Venous congestion is a recognised complication of medial plantar flaps. The patient described in this case report had a medial ankle defect with exposed bone, for which a proximally pedicled medial plantar flap was used. As we raised the flap, both venae comitantes of the medial planter artery were found to be disrupted. The flap was raised based on the superficial veins draining into the great saphenous, as the only system for venous drainage, with no evidence of venous congestion. The flap was successfully transposed into the defect and healed with no complications. The proximally pedicled medial plantar flap can safely rely on the superficial venous system alone for drainage. In addition, preserving the superficial veins minimise the risk of venous congestion in this flap. We recommend preservation of superficial venous system when possible. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
The "Tokyo" consensus on propeller flaps.
Pignatti, Marco; Ogawa, Rei; Hallock, Geoffrey G; Mateev, Musa; Georgescu, Alexandru V; Balakrishnan, Govindasamy; Ono, Shimpei; Cubison, Tania C S; D'Arpa, Salvatore; Koshima, Isao; Hyakusoku, Hikko
2011-02-01
Over the past few years, the use of propeller flaps, which base their blood supply on subcutaneous tissue or isolated perforators, has become increasingly popular. Because no consensus has yet been reached on terminology and nomenclature of the propeller flap, different and confusing uses of the term can be found in the literature. In this article, the authors report the consensus on the definition and classification of propeller flaps reached by the authors that gathered at the First Tokyo Meeting on Perforator and Propeller Flaps in June of 2009. Some peculiar aspects of the surgical technique are discussed. A propeller flap can be defined as an "island flap that reaches the recipient site through an axial rotation." The classification is based on the nourishing pedicle (subcutaneous pedicled propeller flap, perforator pedicled propeller flap, supercharged propeller flap), the degrees of skin island rotation (90 to 180 degrees) and, when possible, the artery of origin of the perforator. The propeller flap is a useful reconstructive tool that can achieve good cosmetic and functional results. A flap should be called a propeller flap only if it fulfils the definition above. The type of nourishing pedicle, the source vessel (when known), and the degree of skin island rotation should be specified for each flap.
State Recognition of Bone Drilling Based on Acoustic Emission in Pedicle Screw Operation.
Guan, Fengqing; Sun, Yu; Qi, Xiaozhi; Hu, Ying; Yu, Gang; Zhang, Jianwei
2018-05-09
Pedicle drilling is an important step in pedicle screw fixation and the most significant challenge in this operation is how to determine a key point in the transition region between cancellous and inner cortical bone. The purpose of this paper is to find a method to achieve the recognition for the key point. After acquiring acoustic emission (AE) signals during the drilling process, this paper proposed a novel frequency distribution-based algorithm (FDB) to analyze the AE signals in the frequency domain after certain processes. Then we select a specific frequency domain of the signal for standard operations and choose a fitting function to fit the obtained sequence. Characters of the fitting function are extracted as outputs for identification of different bone layers. The results, which are obtained by detecting force signal and direct measurement, are given in the paper. Compared with the results above, the results obtained by AE signals are distinguishable for different bone layers and are more accurate and precise. The results of the algorithm are trained and identified by a neural network and the recognition rate reaches 84.2%. The proposed method is proved to be efficient and can be used for bone layer identification in pedicle screw fixation.
Hai, Henglin; Li, Huatao; Chen, Yang; Li, Qiang; Wu, Shenggang; Lili, Wang; Yan, Lei; Xiaoying, Zhou
2013-03-01
To investigate the effectiveness of pedicled superior gluteal artery perforator bilateral quadrilobed flaps for repairing large sacrococcygeal pressure sores. Between June 2003 and August 2011, 6 paraplegia patients with large sacrococcygeal pressure sores were repaired with the pedicled superior gluteal artery perforator bilateral quadrilobed flaps. There were 2 males and 4 females with an average age of 45.6 years (range, 37-62 years). The mean disease duration was 8.4 months (range, 3-26 months). According to National Pressure Ulcer Advisory Panel (NPUAP) standard, 6 cases rated as degree IV. The size of pressure sores ranged from 15 cm x 13 cm to 18 cm x 16 cm. The size of flaps ranged from 18 cm x 14 cm to 21 cm x 15 cm. After operation, all flaps survived successfully. The wounds healed by first intention in 5 cases; partial dehiscence of incision occurred in 1 case, which was cured after dressing change for 26 days. Six patients were followed up 6-24 months (mean, 12.5 months). The appearance and texture of the flaps were smooth and soft with good elasticity and no ulceration. Pedicled superior gluteal artery perforator bilateral quadrilobed flaps can repair large sacrococcygeal pressure sores. The appearance of flaps is smooth and has good compression-resistance effect.
Golbin, Denis A.; Lasunin, Nikolay V.; Cherekaev, Vasily A.; Polev, Georgiy A.
2016-01-01
Objectives To evaluate the efficacy and safety of using a buccal fat pad for endoscopic skull base defect reconstruction. Design Descriptive anatomical study with an illustrative case presentation. Setting Anatomical study was performed on 12 fresh human cadaver specimens with injected arteries (24 sides). Internal carotid artery was exposed in the coronal plane via the endoscopic transpterygoid approach. The pedicled buccal fat pad was used for reconstruction. Participants: 12 human cadaver head specimens; one patient operated using the proposed technique. Main outcome measures: Proximity of the buccal fat pad flap to the defect, compliance of the flap, comfort and safety of harvesting procedure, and compatibility with the Hadad–Bassagasteguy nasoseptal flap. Results: Harvesting procedure was performed using anterior transmaxillary corridor. The pedicled buccal fat pad flap can be used to pack the sphenoid sinus or cover the internal carotid artery from cavernous to upper parapharyngeal segment. Conclusion The buccal fat pad can be safely harvested through the same approach without external incisions and is compliant enough to conform to the skull base defect. The proposed pedicled flap can replace free abdominal fat in central skull base reconstruction. The volume of the buccal fat pad allows obliteration of the sphenoid sinus or upper parapharyngeal space. PMID:28180047
Santanelli Di Pompeo, Fabio; Longo, Benedetto; Pagnoni, Marco; Laporta, Rosaria
2015-05-01
Recidivating pressure sores are a frequent complication in meningomyelocele patients because of their limitation in motility and their scarce ability to monitor the pressure applied on insensate areas while seated. We report the utilization of the sensate pedicled anterolateral thigh perforator flap for reconstruction of ischiatic sores in meningomyelocele patients. Between May 2011 and September 2013, five patients underwent transfer of a sensate pedicled anterolateral thigh flap, by an intermuscular passageway through the upper thigh, to reach the ischial defect. Flap was properly harvested from the thigh after assessment of the lateral cutaneous femoral nerve sensitive area with the Pressure-Specified Sensory Device. In all cases the flap reached the ischial defect harmlessly, healing was uneventful with no immediate nor late complications. Each patient showed persistence of sensitivity at the reconstructed area and no recurrent ischiatic sore was observed at mean follow-up of 26.4 months. The sensate pedicled anterolateral thigh flap is a valuable solution for coverage of recurrent ischial sores in meningomyelocele patients, in which pressure consciousness is fundamental. The intermuscular passageway allows to reduce the distance between flap's vascular pedicle origin and the ischial defect, hence to use the more reliable skin from the middle third of the anterolateral thigh. © 2014 Wiley Periodicals, Inc.
Breast implant capsule-associated squamous cell carcinoma: a report of 2 cases.
Olsen, Daniel L; Keeney, Gary L; Chen, Beiyun; Visscher, Daniel W; Carter, Jodi M
2017-09-01
The use of prosthetic implants for breast augmentation has become commonplace. Although implants do not increase the risk of conventional mammary carcinoma, they are rarely associated with anaplastic large cell lymphoma. We report 2 cases of breast implant capsule-associated squamous cell carcinoma with poor clinical outcomes. Both patients (56-year-old woman and 81-year-old woman) had long-standing implants (>25 years) and presented with acute unilateral breast enlargement. In both cases, squamous cell carcinoma arose in (focally dysplastic) squamous epithelium-lined breast implant capsules and widely invaded surrounding breast parenchyma or chest wall. Neither patient had evidence of a primary mammary carcinoma or squamous cell carcinoma at any other anatomic site. Within 1 year, one patient developed extensive, treatment-refractory, locoregional soft tissue metastasis, and the second patient developed hepatic and soft tissue metastases and died of disease. There are 2 prior reported cases of implant-associated squamous cell carcinoma in the plastic surgery literature; one provides no pathologic staging or outcome information, and the second case was a capsule-confined squamous cell carcinoma. Together, all 4 cases share notable commonalities: the patients had long-standing breast implants and presented with acute unilateral breast pain and enlargement secondary to tumors arising on the posterior aspect of squamous epithelialized implant capsules. Because of both its rarity and its unusual clinical presentation, implant capsule-associated squamous cell carcinoma may be underrecognized. The aggressive behavior of the tumors in this series underscores the importance of excluding malignancy in patients with long-standing breast implants who present with acute unilateral breast pain and enlargement. Copyright © 2017 Elsevier Inc. All rights reserved.
Pharmacologic Plus Optical Penalization Treatment for Amblyopia: Results of a Randomized Trial
2008-01-01
Objective To compare weekend atropine augmented by a plano lens for the sound eye with weekend atropine alone for moderate amblyopia in children 3 to <7 years old. Methods In a multi-center clinical trial, 180 children with moderate amblyopia (20/40 to 20/100) were randomized to weekend atropine augmented by a plano lens or weekend atropine alone. Main Outcome Measure Masked assessment of amblyopic eye visual acuity using the Amblyopia Treatment Study HOTV testing protocol at 18 weeks. Results At 18 weeks, amblyopic eye improvement averaged 2.8 lines in the atropine plus plano lens group and 2.4 lines in the atropine alone group (mean difference between groups adjusted for baseline acuity 0.3 lines; 95% confidence interval, −0.2 to 0.8). Amblyopic eye acuity was 20/25 or better in 24 (29%) patients in the atropine-only group and 35 (40%) patients in the atropine plus plano lens group (P=0.03). More patients in the atropine plus plano lens group had reduced sound eye acuity at 18 weeks; however, there were no cases of persistent reverse amblyopia. Conclusions As an initial treatment for moderate amblyopia, the augmentation of weekend atropine with a plano lens does not substantially improve amblyopic eye acuity when compared with atropine alone. Application to Clinical Practice Treatment of children with unilateral amblyopia Trial Registry Name Trial Comparing Atropine to Atropine Plus a Plano Lens for the Sound Eye for Amblyopia in Children 3 to <7 Years Old PMID:19139333
Bachour, E; Coloma, P; Freitas, E; Messerer, R; Michel, F; Barrey, C
2016-12-01
We report a case of three patients treated with pedicle subtraction osteotomy for post-vertebroplasty kyphosis. These patients were initially treated with a vertebroplasty for vertebral fracture (two cases) and spinal lymphoma (1 case). All of these patients worsened progressively on a clinical and radiographic level with progression of the spinal deformity in the form of kyphosis. The surgery consisted of transpedicular osteotomy instrumented at the level of the vertebra cemented with maximum removal of intra-corporeal cement. One of the three patients required a supplementary anterior approach to achieve good quality bone fusion. In all three cases the post-vertebroplasty kyphosis was able to be reduced by at least 50 % emphasizing the feasibility and relevance of the pedicle subtraction osteotomy in a context of cemented vertebra. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
The evolution of image-guided lumbosacral spine surgery.
Bourgeois, Austin C; Faulkner, Austin R; Pasciak, Alexander S; Bradley, Yong C
2015-04-01
Techniques and approaches of spinal fusion have considerably evolved since their first description in the early 1900s. The incorporation of pedicle screw constructs into lumbosacral spine surgery is among the most significant advances in the field, offering immediate stability and decreased rates of pseudarthrosis compared to previously described methods. However, early studies describing pedicle screw fixation and numerous studies thereafter have demonstrated clinically significant sequelae of inaccurate surgical fusion hardware placement. A number of image guidance systems have been developed to reduce morbidity from hardware malposition in increasingly complex spine surgeries. Advanced image guidance systems such as intraoperative stereotaxis improve the accuracy of pedicle screw placement using a variety of surgical approaches, however their clinical indications and clinical impact remain debated. Beginning with intraoperative fluoroscopy, this article describes the evolution of image guided lumbosacral spinal fusion, emphasizing two-dimensional (2D) and three-dimensional (3D) navigational methods.
Congenital aplastic-hypoplastic lumbar pedicle in infants and young children
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yousefzadeh, D.K.; El-Khoury, G.Y.; Lupetin, A.R.
1982-01-01
Nine cases of congenital aplastic-hypoplastic lumbar pedicle (mean age 27 months) are described. Their data are compared to those of 18 other reported cases (mean age 24.7 years) and the following conclusions are made: (1) Almost exclusively, the pedicular defect in infants and young children is due to developmental anomaly rather than destruction by malignancy or infectious processes. (2) This anomaly, we think, is more common than it is believed to be. (3) Unlike adults, infants and young children rarely develop hypertrophy and/or sclerosis of the contralateral pedicle. (4) Detection of pedicular anomaly is more than satisfying a radiographic curiositymore » and may lead to discovery of other coexisting anomalies. (5) Ultrasonic screening of the patients with congenital pedicular defects may detect the associated genitourinary anomalies, if present, and justify further studies in a selected group of patients.« less
Novel technique for preoperative pedicle localization in spinal surgery with challenging anatomy.
Young, Richard M; Prasad, Vikram; Wind, Joshua J; Olan, Wayne; Caputy, Anthony J
2014-04-01
Accurately localizing a spine level in the thoracic spine is often not easily achieved with the existing imaging modalities available in the operating room. The coordination of the preoperative imaging pathology with intraoperative imaging is even more difficult in patients with challenging anatomy. Using standard percutaneous techniques, the authors placed a radiopaque embolization coil into the pedicle of interest under biplanar fluoroscopy in 1 patient. Thoracic spine MRI along with scout MRI was then performed to confirm coil marker placement in relation to the actual spine pathology prior to surgical intervention. No complications were observed during placement of the radiopaque marker. Intraoperatively, the marker was immediately and easily visualized, leading to a confident identification of the correct thoracic spinal level. The preoperative placement of a radiopaque marker into the vertebral pedicle of the identified pathological level combined with postplacement MRI verification provides an advantage over previously proposed techniques in the literature.
Fifty years of migraine research.
Lance, J W
1988-05-01
The prevalence of ice-pick pains and ice-cream headache in migrainous patients and their localisation to the habitual site of migraine headache, suggest that segments of the central pain pathways remain hyperexcitable between spontaneous attacks. Excessive afferent stimulation (flashing lights, noise, strong perfumes) or hypothalamic changes resulting from emotion, stress or the operation of some internal clock may set in motion brainstem mechanisms, including spontaneous unilateral or bilateral discharge of pain pathways. Studies in the experimental animal have shown that certain monoaminergic brainstem nuclei can influence the cerebral circulation unilaterally and that they and the trigeminal system can induce a reflex dilatation of the external carotid circulation. Descending pathways from the same brainstem nuclei cause the adrenal gland to secrete noradrenaline, which in turn can release serotonin from blood platelets. Free serotonin may become adsorbed to the arterial wall, thus increasing sensitivity to pain, augmenting afferent input and adding a pulsating quality to migrainous pain. Both neural and vascular components of migraine implicate monoamines, specifically noradrenaline and serotonin, as neurotransmitters and humoral agents. The recent pharmacological classification of serotonin (5HT) receptors indicates that agonists of a subset of the 5HT1 receptor and antagonists of 5HT2 receptors are most likely to be helpful in the treatment of migraine.
Yin, Yiheng; Yu, Xinguang; Tong, Huaiyu; Xu, Tao; Wang, Peng; Qiao, Guangyu
2015-10-06
To investigate the clinical application value of the 3D printing technique in the treatment of basilar invagination and atlantoaxial dislocation. From January 2013 to September 2013, 10 patients with basilar invagination and atlantoaxial dislocation needing posterior fixation undertook 3D printing modes at the Department of Neurosurgery in PLA General Hospital. The 1:1 size models were established from skull base to C4 level with different colors between bone structures and vertebral arteries. The simulation of screw insertion was made to investigate the fixation plan and ideal entry point to avoid vertebral artery injury. After obtaining the individual screw insertion data in 3D printing modes, the according surgical operations were performed. The actual clinical results and virtual screw data in 3D printing mode were compared with each other. The 3D printing modes revealed that all the 10 patients had the dysplasia or occipitalized C1 posterior arch indicating C1 posterior arch screw implantation was not suitable. C1 lateral masses were chosen as the screws entry points. C2 screws were designed individually based on the 3D printing modes as follows: 3 patients with aberrant vertebral artery or narrow C2 pedicle less than 3.5 mm were not suitable for pedicle screw implantation. Among the 3 patients, 1 was fixed with C2 laminar screw, and 1 with C2-3 transarticular screw and 1 with C3 pedicle screw (also combined with congenital C2-3 vertebral fusion). Two patients with narrow C2 pedicle between 3.5 and 4mm were designed to choose pedicle screw fixation after 3D printing mode evaluation. One patient with C1 lateral mass vertically dislocated axis was planned with C1-2 transarticular screw fixation. All the other patients were planned with C2 pedicle screws. All the 10 patients had operation designed as the 3D printing modes schemes. The follow-up ranged from 12 to 18 months and all the patients recovered from the clinical symptoms and the bony fusion attained to 100%. 3D printing mode could provide thorough information of the bony structure abnormalities and route of vertebral artery. It is helpful for setting operation strategy and designing screw entry point and trajectory and avoiding vertebral artery and spinal cord injury and thus deserves generalization.
Postero-Inferior Pedicle Surgical Technique for the Treatment of Grade III Gynecomastia.
Thiénot, Sophie; Bertheuil, Nicolas; Carloni, Raphaël; Méal, Cécile; Aillet, Sylvie; Herlin, Christian; Watier, Eric
2017-06-01
Surgical treatment of Grade III gynecomastia generally utilizes mastectomy techniques and free transplantation of the nipple-areola complex. Moreover, with rising obesity rates and the development of bariatric surgery, an increasing demand for correctional surgery for pseudogynecomastia has been observed, which is comparable to Grade III gynecomastia in terms of its surgical management. Here, we describe an innovative technique to deal with these new demands: fascio-cutaneous flap by postero-inferior pedicle. All patients in the Department of Plastic Surgery from our University Hospital suffering from Grade III gynecomastia or pseudogynecomastia underwent surgery via the postero-inferior pedicle flap technique. Briefly, we performed extensive liposuction of the infero-internal and infero-external mammary quadrants followed by liposuction of the deep tissues of the superior quadrants, except in the area of the pedicle. After removing the skin just above the dermis of the inferior quadrants and performing de-epithelialization of the postero-inferior pedicle flap, the thoracic flap was lowered and the areola transposed. Nine patients underwent surgery between March 2015 and March 2016, and their results were collected prospectively. The mean patient age was 46.6 years, the mean weight was 94.2 kg, and the mean body mass index was 30.8 kg/m 2 . In addition, the mean operative time was 132 min, the mean liposuction volume was 633 mL, the excised weight was 586 g, and the mean hospitalization and drainage durations were 3.8 days. No major complications occurred, no re-intervention was required, and no recurrence was found. We report a new operative technique using a postero-inferior pedicle. Its main advantage is preservation of neurovascular function, which makes this a promising technique for patients who wish to maintain nipple sensitivity. This surgery is reliable and reproducible. We recommend it as the first line treatment for Grade III gynecomastia because of its low rate of major complications and favorable functional and esthetic results. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Abe, Yuichiro; Ito, Manabu; Abumi, Kuniyoshi; Kotani, Yoshihisa; Sudo, Hideki; Minami, Akio
2011-11-01
Use of computer-assisted spine surgery (CASS) technologies, such as navigation systems, to improve the accuracy of pedicle screw (PS) placement is increasingly popular. Despite of their benefits, previous CASS systems are too expensive to be ubiquitously employed, and more affordable and portable systems are desirable. The aim of this study was to introduce a novel and affordable computer-assisted technique that 3-dimensionally visualizes anatomical features of the pedicles and assists in PS insertion. The authors have termed this the 3D-visual guidance technique for inserting pedicle screws (3D-VG TIPS). The 3D-VG technique for placing PSs requires only a consumer-class computer with an inexpensive 3D DICOM viewer; other special equipment is unnecessary. Preoperative CT data of the spine were collected for each patient using the 3D-VG TIPS. In this technique, the anatomical axis of each pedicle can be analyzed by volume-rendered 3D models, as with existing navigation systems, and both the ideal entry point and the trajectory of each PS can be visualized on the surface of 3D-rendered images. Intraoperative guidance slides are made from these images and displayed on a TV monitor in the operating room. The surgeon can insert PSs according to these guidance slides. The authors enrolled 30 patients with adolescent idiopathic scoliosis (AIS) who underwent posterior fusion with segmental screw fixation for validation of this technique. The novel technique allowed surgeons, from office or home, to evaluate the precise anatomy of each pedicle and the risks of screw misplacement, and to perform 3D preoperative planning for screw placement on their own computer. Looking at both 3D guidance images on a TV monitor and the bony structures of the posterior elements in each patient in the operating theater, surgeons were able to determine the best entry point for each PS with ease and confidence. Using the current technique, the screw malposition rate was 4.5% in the thoracic region in corrective surgery for AIS. The authors found that 3D-VG TIPS worked on a consumer-class computer and easily visualized the ideal entry point and trajectory of PSs in any operating theater without costly special equipment. This new technique is suitable for preoperative planning and intraoperative guidance when performing reconstructive surgery with PSs.
Cost-effectiveness of Early Division of the Forehead Flap Pedicle.
Calloway, Hollin E; Moubayed, Sami P; Most, Sam P
2017-09-01
The paramedian forehead flap is considered the gold standard procedure to optimally reconstruct major defects of the nose, but this procedure generally requires 2 stages, where the flap pedicle is divided 3 weeks following the initial surgery to ensure adequate revascularization of the flap from the surrounding recipient tissue bed, which can cost a patient time out of work or away from normal social habits. It has previously been shown that the pedicle may be safely divided after 2 weeks in select patients where revascularization from the recipient bed was confirmed using intraoperative laser fluorescence angiography to potentially save the patient time and money. To demonstrate the cost-effectiveness of takedown of the paramedian forehead flap pedicle after 2 weeks using angiography with indocyanine green (ICG). Retrospective cohort study of all patients who underwent 2-week division of the forehead flap after nasal reconstruction. Patient, tumor, defect, and outcomes data were collected. Cost-minimization analysis was performed by comparing the overall costs of 2-week takedown with angiography to a hypothetical patient undergoing 3-week takedown without angiography. Two-week division of the forehead flap after nasal reconstruction. Cost-minimization analysis performed by calculating the total variable costs for a patient in our cohort vs costs to a theoretical patient for whom angiography was not performed and the pedicle was divided at the 3-week mark. A total of 22 patients were included (mean [SD] age, 70.3 [10.0] years; 8 women [36.4%] and 14 men [63.6%]). The selection criteria for 2-week division of the pedicle are a wound bed with at least 50% vascularized tissue present, partial-thickness defects, and absence of nicotine use. All were divided at the 2-week mark with no instances of flap necrosis. One patient had a squamous eccrine carcinoma histology before reconstruction, all other patients had basal cell carcinoma, squamous cell carcinoma, and melanoma. Cost-minimization analysis showed that the use of angiography with ICG results in cost savings of $177 per patient on average. Two-week takedown of select paramedian forehead flap patients can be performed safely with verification using angiography with ICG. Although this technology inherently adds cost, it is cost-effective, saving a total of $177 per patient. NA.
Tsirikos, A I; Mataliotakis, G; Bounakis, N
2017-08-01
We present the results of correcting a double or triple curve adolescent idiopathic scoliosis using a convex segmental pedicle screw technique. We reviewed 191 patients with a mean age at surgery of 15 years (11 to 23.3). Pedicle screws were placed at the convexity of each curve. Concave screws were inserted at one or two cephalad levels and two caudal levels. The mean operating time was 183 minutes (132 to 276) and the mean blood loss 0.22% of the total blood volume (0.08% to 0.4%). Multimodal monitoring remained stable throughout the operation. The mean hospital stay was 6.8 days (5 to 15). The mean post-operative follow-up was 5.8 years (2.5 to 9.5). There were no neurological complications, deep wound infection, obvious nonunion or need for revision surgery. Upper thoracic scoliosis was corrected by a mean 68.2% (38% to 48%, p < 0.001). Main thoracic scoliosis was corrected by a mean 71% (43.5% to 8.9%, p < 0.001). Lumbar scoliosis was corrected by a mean 72.3% (41% to 90%, p < 0.001). No patient lost more than 3° of correction at follow-up. The thoracic kyphosis improved by 13.1° (-21° to 49°, p < 0.001); the lumbar lordosis remained unchanged (p = 0.58). Coronal imbalance was corrected by a mean 98% (0% to 100%, p < 0.001). Sagittal imbalance was corrected by a mean 96% (20% to 100%, p < 0.001). The Scoliosis Research Society Outcomes Questionnaire score improved from a mean 3.6 to 4.6 (2.4 to 4, p < 0.001); patient satisfaction was a mean 4.9 (4.8 to 5). This technique carries low neurological and vascular risks because the screws are placed in the pedicles of the convex side of the curve, away from the spinal cord, cauda equina and the aorta. A low implant density (pedicle screw density 1.2, when a density of 2 represents placement of pedicle screws bilaterally at every instrumented segment) achieved satisfactory correction of the scoliosis, an improved thoracic kyphosis and normal global sagittal balance. Both patient satisfaction and functional outcomes were excellent. Cite this article: Bone Joint J 2017;99-B:1080-7. ©2017 The British Editorial Society of Bone & Joint Surgery.
What is the learning curve for robotic-assisted pedicle screw placement in spine surgery?
Hu, Xiaobang; Lieberman, Isador H
2014-06-01
Some early studies with robotic-assisted pedicle screw implantation have suggested these systems increase accuracy of screw placement. However, the relationship between the success rate of screw placement and the learning curve of this new technique has not been evaluated. We determined whether, as a function of surgeon experience, (1) the success rate of robotic-assisted pedicle screw placement improved, (2) the frequency of conversion from robotic to manual screw placement decreased, and (3) the frequency of malpositioned screws decreased. Between June 2010 and August 2012, the senior surgeon (IHL) performed 174 posterior spinal procedures using pedicle screws, 162 of which were attempted with robotic assistance. The use of the robotic system was aborted in 12 of the 162 procedures due to technical issues (registration failure, software crash, etc). The robotic system was successfully used in the remaining 150 procedures. These were the first procedures performed with the robot by the senior surgeon, and in this study, we divided the early learning curve into five groups: Group 1 (Patients 1-30), Group 2 (Patients 31-60), Group 3 (Patients 61-90), Group 4 (Patients 91-120), and Group 5 (Patients 121-150). One hundred twelve patients (75%) had spinal deformity and 80 patients (53%) had previous spine surgery. The accuracy of screw placement in the groups was assessed based on intraoperative biplanar fluoroscopy and postoperative radiographs. The results from these five groups were compared to determine the effect on the learning curve. The numbers of attempted pedicle screw placements were 359, 312, 349, 359, and 320 in Groups 1 to 5, respectively. The rates of successfully placed screws using robotic guidance were 82%, 93%, 91%, 95%, and 93% in Groups 1 to 5. The rates of screws converted to manual placement were 17%, 7%, 8%, 4%, and 7%. Of the robotically placed screws, the screw malposition rates were 0.8%, 0.3%, 1.4%, 0.8%, and 0%. The rate of successfully placed pedicle screws improved with increasing experience. The rate of the screws that were converted to manual placement decreased with increasing experience. The frequency of screw malposition was similar over the learning curve at 0% to 1.4%. Future studies will need to determine whether this finding is generalizable to others. Level III, therapeutic study. See the Instructions for Authors for a complete description of levels of evidence.
Mahesh, Bijjawara; Upendra, Bidre; Vijay, Sekharappa; Arun, Kumar; Srinivasa, Reddy
2017-03-01
More than half of the perforations reported with usage of cervical pedicle screws (CPS) are lateral perforations, endangering the vertebral artery. The medial cortical pedicle screw (MCPS) technique with partial drilling of the medial cortex shifts the trajectory of pedicle screws medially, decreasing the lateral perforations. To evaluate the decrease in lateral perforations of CPS with use of MCPS technique, in relation to medial angulation. Retrospective analysis and technical report of the MCPS technique and its safety. A total of 58 patients operated on between December 2011 and May 2015 with insertion of pedicle screws from C3 to C7 were included in the study. Axial reconstructed computed tomography (CT) scan images of the inserted screws were evaluated for placement, perforations, and transverse plane angulations using the Surgimap software (Surgimap Spine 1.1.2.271 Intl. 2009 Nemaris LLC). The angulations of screws were analyzed by the type and level of placement through unpaired t test and analysis of variance test. A total of 58 patients operated on between December 2011 and May 2015 with insertion of pedicle screws from C3 to C7 were included in the study. There were 49 males and 9 females. Thirty-seven patients had cervical trauma, 17 had cervical spondylotic myelopathy, two had tumors, and two had ankylosing spondylitis. The average age was 49 years (range 18 to 80 years). The screws were inserted using the MCPS technique. All patients underwent postoperative CT scans with GE Optima CT540 16 slice CT scanner (GE Healthcare Chalfont St. Giles, Buckinghamshire, UK). Axial reconstructed images along the axis of the inserted screws were evaluated for placement and perforations. Further, all the screws were evaluated for transverse plane angulations using the Surgimap software. The angulations of screw were analyzed by the type and level of placement through unpaired t test and analysis of variance test. No funds were received by any of the authors for the purpose of the present study. A total of 324 screws were assessed with postoperative CT scans. Two hundred fifty-six were found to be placed within the pedicle and 68 (20.98%) screws were found to have perforations. Forty screws (12.34%) had grade I medial perforations, 14 screws (4.32%) had grade I lateral perforations, 10 screws (3.08%) had grade II medial perforations, and 4 screws (1.23%) had grade IIlateral perforations. The average angulation of the nonperforated screws (n=256) was 28.6° (43°-17°), that of laterally perforated screws was 20.33° (13°-24°), and that of the medially perforated screws was 34.94° (45°-20°). On statistical analysis with each series, the 99% CI range for the in-screw angles was 27.91° to 29.34°; for the laterally perforated screw series, it was 18.42° to 22.23°; and that for the medially perforated screw series was 32.97° to 36.9°. The MCPS technique represents a shift in the concept of placement of CPS from the cancellous core to the medial cortex, avoiding screw deflection laterally by the thick proximal medial cortex. The present study shows that the lateral perforations can be consistently avoided, with a medial angulation of more than 27.91°, which is the primary concern with the use of pedicle screws in lower cervical spine. Further, the MCPS technique reduces the lateral perforations at a lesser insertion angle, which is technically desirable. Copyright © 2016 Elsevier Inc. All rights reserved.
Perkins, Guy A; Scott, Ray; Perez, Alex; Ellisman, Mark H; Johnson, Jerry E; Fox, Donald A
2012-01-01
Postnatal lead exposure produces rod-selective and Bax-mediated apoptosis, decreased scotopic electroretinograms (ERGs), and scotopic and mesopic vision deficits in humans and/or experimental animals. Rod, but not cone, inner segment mitochondria were considered the primary site of action. However, photoreceptor synaptic mitochondria were not examined. Thus, our experiments investigated the structural and functional effects of environmentally relevant postnatal lead exposure on rod spherule and cone pedicle mitochondria and whether Bcl-xL overexpression provided neuroprotection. C57BL/6N mice pups were exposed to lead only during lactation via dams drinking water containing lead acetate. The blood [Pb] at weaning was 20.6±4.7 µg/dl, which decreased to the control value by 2 months. To assess synaptic mitochondrial structural differences and vulnerability to lead exposure, wild-type and transgenic mice overexpressing Bcl-xL in photoreceptors were used. Electron microscopy, three-dimensional electron tomography, and retinal and photoreceptor synaptic terminal oxygen consumption (QO(2)) studies were conducted in adult control, Bcl-xL, lead, and Bcl-xL/lead mice. The spherule and pedicle mitochondria in lead-treated mice were swollen, and the cristae structure was markedly changed. In the lead-treated mice, the mitochondrial cristae surface area and volume (abundance: measure correlated with ATP (ATP) synthesis) were decreased in the spherules and increased in the pedicles. Pedicles also had an increased number of crista segments per volume. In the lead-treated mice, the number of segments/crista and fraction of cristae with multiple segments (branching) similarly increased in spherule and pedicle mitochondria. Lead-induced remodeling of spherule mitochondria produced smaller cristae with more branching, whereas pedicle mitochondria had larger cristae with more branching and increased crista junction (CJ) diameter. Lead decreased dark- and light-adapted photoreceptor and dark-adapted photoreceptor synaptic terminal QO(2). Bcl-xL partially blocked many of the lead-induced alterations relative to controls. However, spherules still had partially decreased abundance, whereas pedicles still had increased branching, increased crista segments per volume, and increased crista junction diameter. Moreover, photoreceptor and synaptic QO(2) were only partially recovered. These findings reveal cellular and compartmental specific differences in the structure and vulnerability of rod and cone inner segment and synaptic mitochondria to postnatal lead exposure. Spherule and pedicle mitochondria in lead-exposed mice displayed complex and distinguishing patterns of cristae and matrix damage and remodeling consistent with studies showing that synaptic mitochondria are more sensitive to Ca(2+) overload, oxidative stress, and ATP loss than non-synaptic mitochondria. The lead-induced decreases in QO(2) likely resulted from the decreased spherule cristae abundance and smaller cristae, perhaps due to Bax-mediated effects as they occurred in apoptotic rod inner segments. The increase in pedicle cristae abundance and CJ diameter could have resulted from increased Drp1-mediated fission, as small mitochondrial fragments were observed. The mechanisms of Bcl-xL-mediated remodeling might occur via interaction with formation of CJ protein 1 (Fcj1), whereas the partial protection of synaptic QO(2) might result from the enhanced efficiency of energy metabolism via Bcl-xL's direct interaction with the F1F0 ATP synthase and/or regulation of cellular redox status. These lead-induced alterations in photoreceptor synaptic terminal mitochondria likely underlie the persistent scotopic and mesopic deficits in lead-exposed children, workers, and experimental animals. Our findings stress the clinical and scientific importance of examining synaptic dysfunction following injury or disease during development, and developing therapeutic treatments that prevent synaptic degeneration in retinal and neurodegenerative disorders even when apoptosis is blocked.
Anita, Vijayaraghavan; Vijayalakshmi, Rajaram; Bhavna, J.; Ramakrishnan, Thyagarajan; Aravindkumar; Bali, Vikram
2008-01-01
Esthetic concerns of the patient have become an essential part of dentistry, especially Periodontics. Periodontal plastic surgery is a rapidly emerging field, which helps us to meet this criterion. Root coverage is being achieved by a variety of techniques namely pedicle grafts and free soft tissue grafts. This article highlights on 2 case reports in which a new pedicle graft technique has been used for root coverage. PMID:20142945
Extending the use of the gracilis muscle flap in perineal reconstruction surgery.
Goldie, Stephen J; Almasharqah, Riyadh; Fogg, Quentin A; Anderson, William
2016-08-01
Reconstruction of the perineum is required following oncological resections. Plastic surgical techniques can be used to restore the aesthetics and function of the perineum. The gracilis myocutaneous flap provides a substantial skin paddle, with minimal donor site morbidity. The flap is pedicled on a perforator from the medial circumflex femoral artery, giving it limited reach across the perineum. Tunnelling the flap under the adductor longus muscle may free up more of the arterial pedicle, increasing its reach. On three female cadavers, bilateral gracilis flaps were raised in the standard surgical manner, giving six flaps in total. With the flaps pedicled across the perineum, the distance from the tip of each flap was measured to the anterior superior iliac spine (ASIS). The flaps were then tunnelled under the adductor longus muscle. The distances to the ASIS were measured again. The average pedicle length was greater than 7 cm. Tunnelling the flap under the adductor longus muscle increased the reach by more than 4 cm on average. Cadaveric dissection has shown that tunnelling of the flap in a novel way increase its reach across the perineum. This additional flexibility improves its use clinically and is of benefit to plastic surgeons operating in perineal reconstruction. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
[Correction of posttraumatic thoracolumbar kyphosis with modified pedicle subtraction osteotomy].
Chen, Fei; Kang, Yijun; Zhou, Bin; Dai, Zhehao
2016-11-28
To evaluate the efficacy and safety of modified pedicle subtraction osteotomy for treatment of thoracolumbar old fracture with kyphosis. Methods: From January 2003 to January 2013, 58 patients of thoracolumbar kyphosis, who underwent modified pedicle subtraction osteotomy, were reviewed. Among them, 45 cases underwent initial operation and 13 cases underwent revision surgery. Preoperative and postoperative kyphotic Cobb's angle, score of back pain, as well as the incidence of complication were accessed by using visual analogue scale (VAS) and Oswestry disability index (ODI). Results: Mean follow-up duration was 42 months (range, 24-60 months). Average operative time was 258 min (range, 190-430 min), while average bleeding was 950 mL (range, 600-1 600 mL). All the patients were significantly improved in function and self-image, and achieved kyphosis correction with 17.9°± 4.3°. VAS of low back pain was decreased by 3.1±0.6; ODI was dropped by 25.3%±5.5%. 3 patients (5.2%) suffered anterior thigh numbness and got recovery after 3 months of follow-up. Complications happened in 19 patients, including 12 with cerebrospinal fluid leak, 4 with superficial wound infection, and 3 with urinary tract infection. All these complications were managed properly and none of them underwent reoperation. Conclusion: Modified pedicle subtraction osteotomy is a safe and effective technique for the treatment of old fracture with kyphosis.
Zhou, Yi-Jun; Yunus, Akbar; Tian, Zheng; Chen, Jiang-Tao; Wang, Chong; Xu, Lei-Lei
2016-01-01
Hemipelvic resections for primary bone tumours require reconstruction to restore weight bearing along anatomic axes. However, reconstruction of the pelvic arch remains a major surgical challenge because of the high rate of associated complications. We used the pedicle screw-rod system to reconstruct the pelvis, and the purpose of this investigation was to assess the oncology, functional outcome and complication rate following this procedure. The purpose of this study was to investigate the operative indications and technique of the pedicle screw-rod system in reconstruction of the stability of the sacroiliac joint after resection of sacroiliac joint tumours. The average MSTS (Musculoskeletal Tumour Society) score was 26.5 at either three months after surgery or at the latest follow-up. Seven patients had surgery-related complications, including wound dehiscence in one, infection in two, local necrosis in four (including infection in two), sciatic nerve palsy in one and pubic symphysis subluxation in one. There was no screw loosening or deep vein thrombosis occurring in this series. Using a pedicle screw-rod after resection of a sacroiliac joint tumour is an acceptable method of pelvic reconstruction because of its reduced risk of complications and satisfactory functional outcome, as well as its feasibility of reconstruction for type IV pelvis tumour resection without elaborate preoperative customisation. Level of evidence: Level IV, therapeutic study. PMID:27095944
Chen, Ziqiang; Wu, Bing; Zhai, Xiao; Bai, Yushu; Zhu, Xiaodong; Luo, Beier; Chen, Xiao; Li, Chao; Yang, Mingyuan; Xu, Kailiang; Liu, Chengcheng; Wang, Chuanfeng; Zhao, Yingchuan; Wei, Xianzhao; Chen, Kai; Yang, Wu; Ta, Dean; Li, Ming
2015-01-01
The purpose of this study was to understand the acoustic properties of human vertebral cancellous bone and to study the feasibility of ultrasound-based navigation for posterior pedicle screw fixation in spinal fusion surgery. Fourteen human vertebral specimens were disarticulated from seven un-embalmed cadavers (four males, three females, 73.14 ± 9.87 years, two specimens from each cadaver). Seven specimens were used to measure the transmission, including tests of attenuation and phase velocity, while the other seven specimens were used for backscattered measurements to inspect the depth of penetration and A-Mode signals. Five pairs of unfocused broadband ultrasonic transducers were used for the detection, with center frequencies of 0.5 MHz, 1 MHz, 1.5 MHz, 2.25 MHz, and 3.5 MHz. As a result, good and stable results were documented. With increased frequency, the attenuation increased (P<0.05), stability of the speed of sound improved (P<0.05), and penetration distance decreased (P>0.05). At about 0.6 cm away from the cortical bone, warning signals were easily observed from the backscattered measurements. In conclusion, the ultrasonic system proved to be an effective, moveable, and real-time imaging navigation system. However, how ultrasonic navigation will benefit pedicle screw insertion in spinal surgery needs to be determined. Therefore, ultrasound-guided pedicle screw implantation is theoretically effective and promising. PMID:25861053
Kärcher, Hans; Feichtinger, Matthias
2014-12-01
Bone defects in the maxillofacial region after ablative surgery require reconstructive surgery, usually using microvascular free flaps. This paper presents a new method of reconstructing extensive defects in patients not suitable for microvascular surgery using prefabrication of a vascularised osteomuscular flap from the scapula or iliac crest bone. Three patients who were treated with this new technique are presented. Two patients (one mandibular defect and one defect in the maxillary region) received prefabricated osteomuscular flaps from the iliac crest bone using the latissimus dorsi muscle as a pedicle. One patient also presenting a mandibular defect after tumour surgery received a scapula transplant for reconstruction of the defect using the pectoralis major muscle as pedicle. In all three cases vital bone could be transplanted. The pedicle was strainless in all three cases. Minor bone loss could be seen initially only in one case. The results are stable now and one patient received dental implants for later prosthetic treatment. The presented two-step surgery provides an excellent method for reconstruction of bony defects in the maxillofacial region in patients where microvascular surgery is not possible due to reduced state of health or lack of recipient vessels. Copyright © 2010. Published by Elsevier Ltd.
A cross flow-through pedicle free latissimus dorsi flap for high voltage electrical burns.
Gencel, Eyuphan; Eser, Cengiz; Kesiktas, Erol; Tabakan, Ibrahim; Yavuz, Metin
2016-06-01
The management of a high voltage electrical injury and lower limb salvage remains a challenging task for plastic surgeons. Reconstruction with flaps is often the only alternative to limb amputation. The purpose of this study was to present a cross flow-through pedicle free latissimus dorsi muscle flap for the salvage of severely traumatized lower limbs perfused by one remaining vessel (a single vessel lower limb) in high voltage electrical injuries. In this retrospective study, between 2000 and 2014, six men underwent cross-leg free Latissimus dorsi muscle flap operations for limb salvage. They had soft tissue lower leg defects due to high voltage electrical injuries. Their medical records were retrospectively reviewed. All had only one artery that perfused the leg. Free pedicled thoracodorsal artery latissimus dorsi flaps were harvested and connected to the contralateral posterior tibial artery. All defects were successfully covered. No flap loss or major amputation occurred during follow-up (mean; 5.9 years). A computerized tomography angiogram showed intact vessel continuity in the recipient vascular system. The patients were able to walk without any apparatus or assistance after long term follow-up. We recommend that the cross flow-through pedicle free muscle flap should be considered as a salvage procedure for single vessel lower extremities resulting from high voltage electrical burns. Extremity perfusion was not compromised by this procedure. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.
Urethroplasty after Urethral Urolume Stent: an International Multicenter Experience.
Angulo, Javier C; Kulkarni, Sanjay; Pankaj, Joshi; Nikolavsky, Dmitriy; Suarez, Pedro; Belinky, Javier; Virasoro, Ramón; DeLong, Jessica; Martins, Francisco E; Lumen, Nicolaas; Giudice, Carlos; Suárez, Oscar A; Menéndez, Nicolás; Capiel, Leandro; López-Alvarado, Damian; Ramirez, Erick A; Venkatesan, Krishnan; Husainat, Maha M; Esquinas, Cristina; Arance, Ignacio; Gómez, Reynaldo; Santucci, Richard
2018-05-08
To evaluate the outcomes and factors affecting success of urethroplasty in patients with stricture recurrence after Urolume® urethral stent. Retrospective international multicenter study on patients treated with urethral reconstruction after Urolume® stent. Stricture and stent length, time between urethral stent insertion and urethroplasty, age, mode of stent retrieval, type of urethroplasty, complications and baseline and post-urethroplasty voiding parameters were analyzed. Successful outcome was defined as standard voiding, without need of any postoperative adjunctive procedure. Sixty-three patients were included. Stent was removed at urethroplasty in 61 patients. Reconstruction technique was excision and primary anastomosis in 14(22.2%), dorsal onlay buccal mucosa graft (BMG) 9(14.3%), ventral onlay BMG 6(9.5%), dorso-lateral onlay BMG 9(14.3%), ventral onlay plus dorsal inlay BMG 3(4.8%), augmented anastomosis 5(7.9%), pedicled flap urethroplasty 6(9.5%), 2-stage procedure 4(6.4%) and perineal urethrostomy 7(11.1%). Success rate was 81% at a mean 59.7+63.4months. Dilatation and/or internal urethrotomy was performed in 10(15.9%), redo-urethroplasty in 5(7.9%). Total IPSS, QoL, Qmax and PVR significantly improved (p<.0001). Complications occurred in 8(12.7%), all Clavien-Dindo <2. Disease-free survival rate after reconstruction was 88.1%,79.5% and 76.7% at 1,3 and 5-years respectively. Explant of individual strands followed by onlay BMG is the most common approach and was significantly advantageous over the other techniques (p=.018). Urethroplasty in patients with Urolume® urethral stents is a viable option of reconstruction with a high success rate and very acceptable complication rate. Numerous techniques are viable, however, urethral preservation, tine-by-tine stent extraction and use of BMG augmentation produced significantly better outcomes. Copyright © 2018 Elsevier Inc. All rights reserved.
Towards cybernetic surgery: robotic and augmented reality-assisted liver segmentectomy.
Pessaux, Patrick; Diana, Michele; Soler, Luc; Piardi, Tullio; Mutter, Didier; Marescaux, Jacques
2015-04-01
Augmented reality (AR) in surgery consists in the fusion of synthetic computer-generated images (3D virtual model) obtained from medical imaging preoperative workup and real-time patient images in order to visualize unapparent anatomical details. The 3D model could be used for a preoperative planning of the procedure. The potential of AR navigation as a tool to improve safety of the surgical dissection is outlined for robotic hepatectomy. Three patients underwent a fully robotic and AR-assisted hepatic segmentectomy. The 3D virtual anatomical model was obtained using a thoracoabdominal CT scan with a customary software (VR-RENDER®, IRCAD). The model was then processed using a VR-RENDER® plug-in application, the Virtual Surgical Planning (VSP®, IRCAD), to delineate surgical resection planes including the elective ligature of vascular structures. Deformations associated with pneumoperitoneum were also simulated. The virtual model was superimposed to the operative field. A computer scientist manually registered virtual and real images using a video mixer (MX 70; Panasonic, Secaucus, NJ) in real time. Two totally robotic AR segmentectomy V and one segmentectomy VI were performed. AR allowed for the precise and safe recognition of all major vascular structures during the procedure. Total time required to obtain AR was 8 min (range 6-10 min). Each registration (alignment of the vascular anatomy) required a few seconds. Hepatic pedicle clamping was never performed. At the end of the procedure, the remnant liver was correctly vascularized. Resection margins were negative in all cases. The postoperative period was uneventful without perioperative transfusion. AR is a valuable navigation tool which may enhance the ability to achieve safe surgical resection during robotic hepatectomy.
Leblanc, Fabien; Delaney, Conor P; Ellis, Clyde N; Neary, Paul C; Champagne, Bradley J; Senagore, Anthony J
2010-12-01
We hypothesized that simulator-generated metrics and intraoperative errors may be able to differentiate the technical differences between hand-assisted laparoscopic (HAL) and straight laparoscopic (SL) approaches. Thirty-eight trainees performed two laparoscopic sigmoid colectomies on an augmented reality simulator, randomly starting by a SL (n = 19) or HAL (n = 19) approach. Both approaches were compared according to simulator-generated metrics, and intraoperative errors were collected by faculty. Sixty-four percent of surgeons were experienced (>50 procedures) with open colon surgery. Fifty-five percent and 69% of surgeons were inexperienced (<10 procedures) with SL and HAL colon surgery, respectively. Time (P < 0.001), path length (P < 0.001), and smoothness (P < 0.001) were lower with the HAL approach. Operative times for sigmoid and splenic flexure mobilization and for the colorectal anastomosis were significantly shorter with the HAL approach. Time to control the vascular pedicle was similar between both approaches. Error rates were similar between both approaches. Operative time, path length, and smoothness correlated directly with the error rate for the HAL approach. In contrast, error rate inversely correlated with the operative time for the SL approach. A HAL approach for sigmoid colectomy accelerated colonic mobilization and anastomosis. The difference in correlation between both laparoscopic approaches and error rates suggests the need for different skills to perform the HAL and the SL sigmoid colectomy. These findings may explain the preference of some surgeons for a HAL approach early in the learning of laparoscopic colorectal surgery.
Wang, Hong-wei; Li, Chang-qing; Zhou, Yue; Zhang, Zheng-feng; Wang, Jian; Chu, Tong-wei
2010-06-01
To prospectively evaluate the feasibility, safety and efficacy of the percutaneous pedicle screw fixation through the pedicle of fractured vertebra in the treatment of type A thoracolumbar fractures using Sextant system in the retrospective non-randomized case-control study. A total of 38 consecutive non-randomized patients with type A thoracolumbar fractures, which had been stabilized posteriorly from December 2006 to March 2009, were examined retrospectively more than 9 months after surgery. Twenty-one patients had been treated conventionally with open pedicle screw fixation (OPSF) and 17 patients received minimally invasive treatment with Sextant percutaneous pedicle screw fixation (SPPSF). As a method of evaluation, the incision size, the intraoperation and postoperative volume of blood loss, operation time, postoperative hospital stay, blood transfusion, the radiological assessment of the sagittal Cobb;s angle, vertebral body angle and vertebral body height were recorded and compared. All patients were followed up for 8-24 months (average 11.6 months). There were significant differences in the incision size, surgical blood loss, surgical draining loss, operation time, hospital stay after operation, blood transfusion, the proportion of antalgic supplement and postoperative incisional VAS between the two groups (P less than 0.05). Mean preoperative kyphotic deformity was 16.0 degree and improved by 9.3 degree after surgery in OPSF group, but 15.2 degree and 10.3 degree respectively in SPPSF group. Mean preoperative angle of the fractured vertebral body was 15.9 degree and improved by 7.9 degree after surgery in OPSF group, but 14.9 degree and 6.6 degree respectively in SPPSF group. Mean anterior vertebral body height (% of normal) was 67.3% before surgery and 95.8% after surgery, but 69.1% and 90.1% respectively in SPPSF group. Mean posterior vertebral body height (% of normal) was 93.3% before surgery and 99.5% after surgery, but 88.9% and 93.3% respectively in SPPSF group. Among the patients whose 9-month follow-up films were available, 3.0 degree of kyphosis correction was lost in OPSF group, but 3.2 degree in SPPSF group. And 1.0 degree of the angle of the fractured vertebral body correction was lost in OPSF group, but 1.5 degree in SPPSF group. Then 3.0% of the anterior vertebral body height correction was lost in OPSF group, but 2.2% in SPPSF group. And 3.0% of the posterior vertebral body height correction was lost in OPSF group, but 2.5% in SPPSF group. The sagittal Cobb's angle, vertebral body angle and anterior height of the fractured vertebra were all significantly different in each group before and after operation (P less than 0.05). There were no significant differences in the postoperative sagittal Cobb's angle, vertebral body angle and the improvement of the vertebral body height and the kyphotic deformity correction between OPSF and SPPSF groups (P larger than 0.05), but there was significant difference in the postoperative anterior height of the fractured vertebra between the two groups (P less than 0.05). The percutaneous pedicle screw fixation through the pedicle of fractured vertebra using Sextant system is a good minimally-invasive surgical therapeutic choice for patients with type A thoracolumbar fracture except for that the SPPSF has a little insufficiency in resuming the anterior height of the fractured vertebra compared with OPSF.
[Precision of navigation-assisted surgery of the thoracic and lumbar spine].
Arand, M; Schempf, M; Hebold, D; Teller, S; Kinzl, L; Gebhard, F
2003-11-01
The goal of these studies was to evaluate the accuracy of in vivo and in vitro application of CT- and C-arm-based navigation at the thoracic and lumbar spine. With CT based navigation, 82 pedicle screws were consecutively inserted, 53 into the thoracic and 29 into the lumbar spine. Seven (13%) perforations were detected at the thoracic spine and two (7%) at the lumbar spine. Additionally, minor perforations below the thread depth were seen in six (11%) thoracic and in two (7%) lumbar instrumentation. With C-arm-based navigation, 74 screws were consecutively placed into 38 thoracic and 36 lumbar pedicles. Perforations were noted in ten (26%) thoracic and four (11%) lumbar implants. Minor perforations were observed in another nine (24%) thoracic and ten (28%) lumbar pedicles. The observer-independent and standardized in vitro study based on a transpedicular 3.2-mm drill hole aiming a 4-mm steel ball in a plastic bone model showed pedicle perforations of the drill canal only in thoracic vertebrae, 1 of 15 in CT-based and 3 of 15 in C-arm navigation. The quantitative calculation of the smallest distance between the central line through the drill canal and the center of the steel ball resulted in 1.4 mm (0.5-4.8 mm) for the CT-based navigation at the thoracic spine and in 1.8 mm (0.5-3 mm) at the lumbar spine. For the C-arm based navigation the distance was 2.6 mm (0.9-4.8 mm) for the thoracic spine and 2 mm (1.2-3 mm) for the lumbar spine. In our opinion, the clinical results of the comparative accuracy of CT- and C-arm-based navigation in the present study showed moderate advantages of the CT-based technique in the thoracic spine, whereas CT- and C-arm based navigation had comparable perforation rates at the lumbar pedicle. The results of the experimental study correlated with the clinical data.
Lee, Byung Ho; Lee, Hwan-Mo; Kim, Tae-Hwan; Kim, Hak-Sun; Moon, Eun-Soo; Park, Jin-Oh; Chong, Hyun-Soo
2012-01-01
Background Infective spondylodiscitis usually occurs in patients of older age, immunocompromisation, co-morbidity, and individuals suffering from an overall poor general condition unable to undergo reconstructive anterior and posterior surgeries. Therefore, an alternative, less aggressive surgical method is needed for these select cases of infective spondylodiscitis. This retrospective clinical case series reports our novel surgical technique for the treatment of infective spondylodiscitis. Methods Between January 2005 and July 2011, among 48 patients who were diagnosed with pyogenic lumbar spondylodiscitis or tuberculosis lumbar spondylodiscitis, 10 patients (7 males and 3 females; 68 years and 48 to 78 years, respectively) underwent transpedicular curettage and drainage. The mean postoperative follow-up period was 29 months (range, 7 to 61 months). The pedicle screws were inserted to the adjacent healthy vertebrae in the usual manner. After insertion of pedicle screws, the drainage pedicle holes were made through pedicles of infected vertebra(e) in order to prevent possible seeding of infective emboli to the healthy vertebra, as the same instruments and utensils are used for both pedicle screws and the drainage holes. A minimum of 15,000 mL of sterilized normal saline was used for continuous irrigation through the pedicular pathways until the drained fluid looked clear. Results All patients' symptoms and inflammatory markers significantly improved clinically between postoperative 2 weeks and postoperative 3 months, and they were satisfied with their clinical results. Radiologically, all patients reached the spontaneous fusion between infected vertebrae and 3 patients had the screw pulled-out but they were clinically tolerable. Conclusions We suggest that our method of transpedicular curettage and drainage is a useful technique in regards to the treatment of infectious spondylodiscitic patients, who could not tolerate conventional combined anterior and posterior surgery due to multiple co-morbidities, multiple level infectious lesions and poor general condition. PMID:22949951
Liu, Hao; Chen, Weikai; Liu, Tao; Meng, Bin; Yang, Huilin
2017-01-01
To investigate the accuracy of pedicle screw placement based on preoperative computed tomography in comparison with intraoperative data set acquisition for spinal navigation system. The PubMed (MEDLINE), EMBASE, and Web of Science were systematically searched for the literature published up to September 2015. This review followed the Preferred Reporting Items for Systematic Reviews and Meta-analysis guidelines. Statistical analysis was performed using the Review Manager 5.3. The dichotomous data for the pedicle violation rate was summarized using relative risk (RR) and 95% confidence intervals (CIs) with the fixed-effects model. The level of significance was set at p < 0.05. For this meta-analysis, seven studies used a total of 579 patients and 2981 screws. The results revealed that the accuracy of intraoperative data set acquisition method is significantly higher than preoperative one using 2 mm grading criteria (RR: 1.82, 95% CI: 1.09, 3.04, I 2 = 0%, p = 0.02). However, there was no significant difference between two kinds of methods at the 0 mm grading criteria (RR: 1.13, 95% CI: 0.88, 1.46, I 2 = 17%, p = 0.34). Using the 2-mm grading criteria, there was a higher accuracy of pedicle screw insertion in O-arm-assisted navigation than CT-based navigation method (RR: 1.96, 95% CI: 1.05, 3.64, I 2 = 0%, p = 0.03). The accuracy between CT-based navigation and two-dimensional-based navigation showed no significant difference (RR: 1.02, 95% CI: 0.35-3.03, I 2 = 0%, p = 0.97). The intraoperative data set acquisition method may decrease the incidence of perforated screws over 2 mm but not increase the number of screws fully contained within the pedicle compared to preoperative CT-based navigation system. A significantly higher accuracy of intraoperative (O-arm) than preoperative CT-based navigation was revealed using 2 mm grading criteria.
A novel anchoring system for use in a nonfusion scoliosis correction device.
Wessels, Martijn; Homminga, Jasper J; Hekman, Edsko E G; Verkerke, Gijsbertus J
2014-11-01
Insertion of a pedicle screw in the mid- and high thoracic regions has a serious risk of facet joint damage. Because flexible implant systems require intact facet joints, we developed an enhanced fixation that is less destructive to spinal structures. The XSFIX is a posterior fixation system that uses cables that are attached to the transverse processes of a vertebra. To determine whether a fixation to the transverse process using the XSFIX is strong enough to withstand the loads applied by the XSLATOR (a novel, highly flexible nonfusion implant system) and thus, whether it is a suitable alternative for pedicle screw fixation. The strength of a novel fixation system using transverse process cables was determined and compared with the strength of a similar fixation using polyaxial pedicle screws on different vertebral levels. Each of the 58 vertebrae, isolated from four adult human cadavers, was instrumented with either a pedicle screw anchor (PSA) system or a prototype of the XSFIX. The PSA consisted of two polyaxial pedicle screws and a 5 mm diameter rod. The XSFIX prototype consisted of two bodies that were fixed to the transverse processes, interconnected with a similar rod. Each fixation system was subjected to a lateral or an axial torque. The PSA demonstrated fixation strength in lateral loading and torsion higher than required for use in the XSLATOR. The XSFIX demonstrated high enough fixation strength (in both lateral loading and torsion), only in the high and midthoracic regions (T10-T12). This experiment showed that the fixation strength of XSFIX is sufficient for use with the XSLATOR only in mid- and high thoracic regions. For the low thoracic and lumbar region, the PSA is a more rigid fixation. Because the performance of the new fixation system appears to be favorable in the high and midthoracic regions, a clinical study is the next challenge. Copyright © 2014 Elsevier Inc. All rights reserved.
Anatomic parameters of the sacral lamina for osteosynthesis in transverse sacral fractures.
Katsuura, Yoshihiro; Lorenz, Eileen; Gardner, Warren
2018-05-01
To analyze the morphometric parameters of the dorsal sacral lamina and pedicles to determine if there is adequate bony architecture to support plate osteosynthesis. Two reviewers performed measurements on 98 randomly selected high-resolution CT scans of the pelvis to quantify the bony anatomy of the sacral lamina. Measurements included the depths of the lamina at each sacral level, the trajectory and depth of the sacral pedicles from the sacral lamina, and the width of the sacral canal. A bone mineral density analysis was performed on the sacral lamina using Hounsfield units (HU) and compared to the L1 and S1 vertebral bodies. The sacral lamina were found to form peaks and troughs which we refered to as major and minor sections. On average, the thickness was > 4 mm at all major screw starting points, indicating adequate geometry for screw fixation. The sacral pedicle depths were 27, 18, 16, and 14 mm at S2-S5, respectively. The average angulation from midline of this screw path directed laterally to avoid the sacral canal was 20°, 17°, 8°, and - 8° for the S2-5 pedicles, respectively. Average sacral canal diameter was 11 mm for S2 and 8 mm for S3-5. The sacral lamina had an average bone mineral density of 635 HU, which was significantly different from the density of the L5 (220 HU) and S1 (165 HU) vertebral bodies (p < 0.005). This morphometric data was used to pilot a new plating technique. The sacral lamina offers a novel target for screw fixation and meets the basic geometric and compositional criteria for screw purchase. To our knowledge, this study represents the first morphometric analysis performed on the sacral lamina and pedicles for plate application.
Are We Underestimating the Significance of Pedicle Screw Misplacement?
Sarwahi, Vishal; Wendolowski, Stephen F; Gecelter, Rachel C; Amaral, Terry; Lo, Yungtai; Wollowick, Adam L; Thornhill, Beverly
2016-05-01
A retrospective review of charts, x-rays (XRs) and computed tomography (CT) scans was performed. To evaluate the accuracy of pedicle screw placement using a novel classification system to determine potentially significant screw misplacement. The accuracy rate of pedicle screw (PS) placement varies from 85% to 95% in the literature. This demonstrates technical ability but does not represent the impact of screw misplacement on individual patients. This study quantifies the rate of screw misplacement on a per-patient basis to highlight its effect on potential morbidity. A retrospective review of charts, XRs and low-dose CT scans of 127 patients who underwent spinal fusion with pedicle screws for spinal deformity was performed. Screws were divided into four categories: screws at risk (SAR), indeterminate misplacements (IMP), benign misplacements (BMP), accurately placed (AP). A total of 2724 screws were placed in 127 patients. A total of 2396 screws were placed accurately (87.96%). A total of 247 screws (9.07%) were BMP, 52 (1.91%) were IMP, and 29 (1.06%) were considered SAR. Per-patient analysis showed 23 (18.11%) of patients had all screws AP. Thirty-five (27.56%) had IMP and 18 (14.17%) had SAR. Risk factor analysis showed smaller Cobb angles increased likelihood of all screws being AP. Sub-analysis of adolescent idiopathic scoliotic patients showed no curve or patient characteristic that correlated with IMP or SAR. Over 40% of patients had screws with either some/major concern. Overall reported screw misplacement is low, but it does not reflect the potential impact on patient morbidity. Per-patient analysis reveals more concerning numbers toward screw misplacement. With increasing pedicle screw usage, the number of patients with misplaced screws will likely increase proportionally. Better strategies need to be devised for evaluation of screw placement, including establishment of a national database of deformity surgery, use of intra-operative image guidance, and reevaluation of postoperative low-dose CT imaging. 3.
Devito, Dennis P; Kaplan, Leon; Dietl, Rupert; Pfeiffer, Michael; Horne, Dale; Silberstein, Boris; Hardenbrook, Mitchell; Kiriyanthan, George; Barzilay, Yair; Bruskin, Alexander; Sackerer, Dieter; Alexandrovsky, Vitali; Stüer, Carsten; Burger, Ralf; Maeurer, Johannes; Donald, Gordon D; Gordon, Donald G; Schoenmayr, Robert; Friedlander, Alon; Knoller, Nachshon; Schmieder, Kirsten; Pechlivanis, Ioannis; Kim, In-Se; Meyer, Bernhard; Shoham, Moshe
2010-11-15
Retrospective, multicenter study of robotically-guided spinal implant insertions. Clinical acceptance of the implants was assessed by intraoperative radiograph, and when available, postoperative computed tomography (CT) scans were used to determine placement accuracy. To verify the clinical acceptance and accuracy of robotically-guided spinal implants and compare to those of unguided free-hand procedures. SpineAssist surgical robot has been used to guide implants and guide-wires to predefined locations in the spine. SpineAssist which, to the best of the authors' knowledge, is currently the sole robot providing surgical assistance in positioning tools in the spine, guided over 840 cases in 14 hospitals, between June 2005 and June 2009. Clinical acceptance of 3271 pedicle screws and guide-wires inserted in 635 reported cases was assessed by intraoperative fluoroscopy, where placement accuracy of 646 pedicle screws inserted in 139 patients was measured using postoperative CT scans. Screw placements were found to be clinically acceptable in 98% of the cases when intraoperatively assessed by fluoroscopic images. Measurements derived from postoperative CT scans demonstrated that 98.3% of the screws fell within the safe zone, where 89.3% were completely within the pedicle and 9% breached the pedicle by up to 2 mm. The remaining 1.4% of the screws breached between 2 and 4 mm, while only 2 screws (0.3%) deviated by more than 4 mm from the pedicle wall. Neurologic deficits were observed in 4 cases yet, following revisions, no permanent nerve damage was encountered, in contrast to the 0.6% to 5% of neurologic damage reported in the literature. SpineAssist offers enhanced performance in spinal surgery when compared to free-hand surgeries, by increasing placement accuracy and reducing neurologic risks. In addition, 49% of the cases reported herein used a percutaneous approach, highlighting the contribution of SpineAssist in procedures without anatomic landmarks.
Aesthetic Penoscrotal Resurfacing: Creating Propeller Flaps from Gluteal Folds.
Han, So-Eun; Kim, Eun-Ji; Sung, Hyun Hwan; Pyon, Jai-Kyong
2018-04-01
Reconstruction of extensive penoscrotal defects is a surgical challenge. Resurfacing defects in highly complex three-dimensional structures and restoring their function are an essential part of the reconstruction of penoscrotal regions. We describe a technique using internal pudendal artery perforator (IPAP) pedicled propeller flaps created from the gluteal fold. This could be a reliable surgical option that maintains a natural looking scrotal pouch with minimal donor site morbidity and optimal sexual activity. We retrospectively reviewed data for 10 consecutive patients who had undergone penoscrotal reconstruction using IPAP pedicled propeller flaps between January 2011 and March 2015. The IPAP was identified using a hand-held Doppler ultrasound device. This was the pivot around which the flap was internally rotated more than 90° in a tension-free manner. The long axis of the flap was centred on the gluteal fold to provide a better-orientated donor site scar. Complications and patient satisfaction with respect to size, colour match, scar appearance, and sexual activity were evaluated. Anatomic and aesthetic penoscrotal reconstruction was performed without any major complications in the follow-up period (mean, 19.7 mo). The mean width of the IPAP pedicled propeller flaps was 6.7cm, and the mean length was 11.7cm. Partial distal flap necrosis occurred in only one case, and healed spontaneously. All of the patients were satisfied with the cosmetic and functional results. On the basis of reliable perforators, donor site morbidity, flap thickness, and a better orientated scar, our technique using IPAP pedicled propeller flaps created from the gluteal fold could be a reasonable surgical option for extensive penoscrotal reconstruction. The creation of pedicled propeller flaps using an internal pudendal artery perforator could be a reliable surgical option for reconstruction of extensive penoscrotal defects. The approach yields functional and aesthetically acceptable surgical results. Copyright © 2016. Published by Elsevier B.V.
Shen, Mingkui; Jiang, Honghui; Luo, Ming; Wang, Wengang; Li, Ning; Wang, Lulu; Xia, Lei
2017-08-02
The correlation between implant density and deformity correction has not yet led to a precise conclusion in adolescent idiopathic scoliosis (AIS). The aim of this study was to evaluate the effects of low density (LD) and high density (HD) pedicle screw instrumentation in terms of the clinical, radiological and Scoliosis Research Society (SRS)-22 outcomes in Lenke 1 AIS. We retrospectively reviewed 62 consecutive Lenke 1 AIS patients who underwent posterior spinal arthrodesis using all-pedicle screw instrumentation with a minimum follow-up of 24 months. The implant density was defined as the number of screws per spinal level fused. Patients were then divided into two groups according to the average implant density for the entire study. The LD group (n = 28) had fewer than 1.61 screws per level, while the HD group (n = 34) had more than 1.61 screws per level. The radiographs were analysed preoperatively, postoperatively and at final follow-up. The perioperative and SRS-22 outcomes were also assessed. Independent sample t tests were used between the two groups. Comparisons between the two groups showed no significant differences in the correction of the main thoracic curve and thoracic kyphosis, blood transfusion, hospital stay, and SRS-22 scores. Compared with the HD group, there was a decreased operating time (278.4 vs. 331.0 min, p = 0.004) and decreased blood loss (823.6 vs. 1010.9 ml, p = 0.048), pedicle screws needed (15.1 vs. 19.6, p < 0.001), and implant costs ($10,191.0 vs. $13,577.3, p = 0.003) in the LD group. Both low density and high density pedicle screw instrumentation achieved satisfactory deformity correction in Lenke 1 AIS patients. However, the operating time and blood loss were reduced, and the implant costs were decreased with the use of low screw density constructs.
Lü, Chunliu; Li, Zan; Zhou, Xiao; Song, Dajiang; Peng, Xiaowei; Zhou, Bo; Yang, Lichang
2016-12-08
To investigate the clinical value of pedicled latissimus dorsi Kiss flap in repairing chest wall large skin defect after tumor operation. A retrospective analysis was made on the clinical data from 15 cases of chest wall tumors treated between December 2010 and December 2015. There were 2 males and 13 females with an average age of 51.8 years (range, 43-60 years); there were 11 cases of locally advanced breast cancer, 3 cases of fibrosarcoma in chest wall, and 1 case of chest wall radiation ulcer with a median disease duration of 24.1 months (range, 6 months to 8 years). The area of skin defects was 17 cm×12 cm to 20 cm×18 cm after primary tumor resection; the pedicled latissimus dorsi Kiss flap was designed to repair wounds. The flap was a two-lobed flap at a certain angle on the surface of latissimus dorsi based on the thoracodorsal artery, with a size of 17 cm×6 cm to 20 cm×9 cm for each lobe. The donor site was sutured directly. Fourteen flaps survived with primary healing of wound; delayed healing was observed in 1 flap because of distal necrosis; and healing by first intention was obtained at the donor sites. The follow-up time was from 6 months to 3 years (mean, 21.6 months). The flap had good appearance with no bloated pedicle. The shoulder joint activities were normal. No local recurrence occurred, but distant metastasis in 2 cases. No obvious scar was found at donor sites. The application of pedicled latissimus dorsi Kiss flap to repair chest wall skin defects after tumor resection has important clinical value, because of the advatages of simple operation, minor donor site damage and rapid postoperative recovery, especially for late stage cancer patients.
Slump, Jelena; Hofer, Stefan O P; Ferguson, Peter C; Wunder, Jay S; Griffin, Anthony M; Hoekstra, Harald J; Bastiaannet, Esther; O'Neill, Anne C
2018-04-12
Flap reconstruction plays an essential role in facilitating limb preservation in patients with extremity soft tissue sarcoma (ESTS). However, the effect of flap choice on the rates of postoperative complications and functional outcomes has not been clearly established. This study directly compares the outcomes of free and pedicled flap reconstructions in patients with ESTS. Two hundred sixty-six patients who underwent flap reconstruction following ESTS resection were included. Associations between flap type and complications were determined using logistic regression analyses. Functional outcome was evaluated using the Toronto Extremity Salvage Score (TESS) and the Musculoskeletal Tumor Society Scales (MSTS). There was no significant difference between complication rates in the pedicled and free flap groups (32% vs. 38%, p = 0.38). In the lower limb, pedicled flaps had complication rates similar to those of free flaps on univariate analysis (odds ratio [OR] = 1.12, 95% confidence interval [CI] = 0.56-2.26, p = 0.75). Conversely, in the upper limb, pedicled flaps were associated with fewer complications on univariate analysis (OR = 0.31, 95% CI = 0.11-0.86, p = 0.03), but this was not significant on multivariate analysis (OR = 0.45, 95% CI = 0.13-1.59, p = 0.22). Obesity was a strong predictor of complications in the upper limb group on multivariate analysis (body mass index [BMI] ≥ 30 kg/m 2 , OR = 7.01, 95% CI = 1.28-38.51, p = 0.03). There was no significant difference in functional outcomes between both flap groups in either upper or lower limbs. Postoperative complications and functional outcomes for patients undergoing free and pedicled flaps are similar in ESTS reconstruction. Selecting the most suitable reconstructive option in each individual case is paramount to preserving function while minimizing postoperative morbidity. Copyright © 2018 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Fossum, T W; Couto, C G; DeHoff, W D; Smeak, D D
1988-12-01
A dog with hemangiopericytoma of the left forelimb underwent surgical excision followed by radiation therapy and thoracic pedicle skin grafting. Recurrence of the neoplasm was not observed 3.5 years after surgery. Hemangiopericytoma is an uncommon neoplasm that seldom metastasizes but has a high recurrence rate. In this dog, complete surgical excision was not possible because of the location and invasiveness of the neoplasm. The combination of surgery, radiotherapy, and skin grafting was a viable alternative to limb amputation.
Lumbar vertebral pedicles: radiologic anatomy and pathology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patel, N.P.; Kumar, R.; Kinkhabwala, M.
1988-01-01
With the advancement of high-resolution computed tomography (CT) scanning the spine has added new knowledge to the various conditions affecting the pedicles. We wish to review the entire spectrum of pedicular lesions: the embryology, normal anatomy, normal variants, pitfalls, congenital anomalies, and pathological conditions are discussed. Different imaging modalities involving CT, isotope bone scanning, and Magnetic Resonance Imaging (MRI) are used to complement plain films of the lumbar spine. This subject review is an excellent source for future reference to lumbar pedicular lesions. 27 references.
Cayarga, Rodrigo; Suzuki, Takanori; Kaufman, Zev
2015-01-01
Purpose. The purpose of this retrospective case series is to describe and compare different surgical techniques that can be utilized to augment the keratinized soft tissue around implant-supported overdentures. Materials and Methods. The data set was extracted as deidentified information from the routine treatment of patients at the Ashman Department of Periodontology and Implant Dentistry at New York University College of Dentistry. Eight edentulous patients were selected to be included in this study. Patients were treated for lack of keratinized tissue prior to implant placement, during the second stage surgery, and after delivery of the final prosthesis. Results. All 8 patients in this study were wearing a complete maxillary and/or mandibular denture for at least a year before the time of the surgery. One of the following surgical techniques was utilized to increase the amount of keratinized tissue: apically positioned flap (APF), pedicle graft (PG), connective tissue graft (CTG), or free gingival graft (FGG). Conclusions. The amount of keratinized tissue should be taken into consideration when planning for implant-supported overdentures. The apical repositioning flap is an effective approach to increase the width of keratinized tissue prior to the implant placement. PMID:26124833
Periodontal regeneration in gingival recession defects.
Trombelli, L
1999-02-01
Surgical treatment of gingival recession defects aims at obtaining soft tissue coverage of exposed root surfaces and/or augmentation of gingival tissue dimensions. A variety of protocols have been developed to manage these clinical problems. Since one goal of periodontal therapy is the regeneration of the lost attachment apparatus of the tooth, full restoration of defect should be accomplished following mucogingival procedures. This implies regeneration of all periodontal structures, including formation of new cementum with inserting connective tissue fibers, alveolar bone regeneration and recreation of a functional and aesthetic morphology of the mucogingival complex. Animal and human histological studies have shown that healing at gingiva-root interface following pedicle flaps or free soft tissue grafts generally includes a long junctional epithelium with varying amounts of a new connective tissue attachment in the most apical aspect of the covered root surface. Limited bone regeneration has been observed. Adjunctive use of root conditioning agents and cell excluding, wound-stabilizing devices may amplify regenerative outcomes. Changes in the amount of keratinized tissue, which can significantly affect the aesthetic outcome of treatment, have been shown to depend on the interactions among various tissues involved in the healing process and the selected surgical procedure.
[Percutaneous treatment of unstable spine fractures - OP video and results from over 300 cases].
Prokop, A; Chmielnicki, M
2014-02-01
Minimally invasive surgery for vertebral fractures results in less approach-related morbidity, decreased postoperative pain, and rapid mobilisation of patients. Such procedures can be performed even in elderly patients. However, along with the many advantages, minimally invasive procedures are technically demanding, require sophisticated tools, and there is a learning curve for surgeons. Intraoperative visualisation is often possible only radiologically, and implants are generally much more expensive. Using the data from over 300 unstable vertebral fracture cases treated over the past 3.5 years, we have developed a differentiated treatment concept, depending on the age of the patient and the fracture characteristics. Unstable fractures with involvement of the posterior edge are stabilised from posterior, percutaneously with a fixator. In patients under 60 years, monoaxial screws with inserted rods (top loading) are used, with which distraction and restoration of lordosis are also possible. Patients over 60 years are treated percutaneously with a polyaxial sextant system with rods inserted to avoid avulsion of the pedicle screws from the vertebral body. To avoid cutting through the vertebra, the fenestrated screws can be augmented with cement. The operation technique is demonstrated by a video. Georg Thieme Verlag KG Stuttgart · New York.
Stübinger, Stefan; Saldamli, Belma; Seitz, Oliver; Sader, Robert; Landes, Constantin A
2009-05-01
The goal of this study was to compare the surgical advantages and disadvantages of a new palatal access osteotomy for sinus elevation with a conventional lateral approach. In 32 patients, either a palatal (n = 16) or a lateral (n = 16) osteotomy to the maxillary sinus was performed under local anesthesia. The palatal access included a circular paramarginal incision and elevation of a palatal mucosal flap based on a median pedicle. The lateral access was performed by vestibular standard incision and development of a mucoperiosteal flap with a vestibular and superior basis. For all osteotomies a piezoelectric device was used. The sinus cavity was augmented with synthetic nanostructured hydroxyapatite graft material. Intraoperative complications during both procedures were minimal and wound healing was uneventful. Membrane perforation occurred in 19% of the palatal group and in 19% of the lateral group. Soft tissue management of the palatal technique was superior to that of the lateral approach, because the vestibular anatomy was not altered and consequently no disharmonious soft tissue scarring and no postoperative swelling occurred. The palatal approach permitted higher postoperative comfort, especially for edentulous patients, because full dentures could be incorporated directly after surgery with almost perfect fit.
Arthrodesis Using Pedicled Fibular Flap After Failed Infected Knee Arthroplasty
Minear, Steve C.; Lee, Gordon; Kahn, David; Goodman, Stuart
2011-01-01
Objective: Severe bone loss associated with failed revision total knee arthroplasty is a challenging scenario. The pedicled fibular flap is a method to obtain vascularized bone for use in knee arthrodesis after failure of a total knee arthroplasty, with substantial loss of bone. Methods: We report 2 successful knee arthrodeses using this method in patients with infected, failed multiply revised total knee arthroplasties. The failed prosthesis was removed, and the bones were aligned and stabilized. The fibular flap was then harvested, fed through a subcutaneous tunnel, and placed within the medullary canal at the arthrodesis site. The soft tissue was closed over the grafts and flaps. Results: Two elderly women presented with pain and drainage from previous total knee arthroplasties after multiple revisions. Arthrodeses were performed as described, and both patients were pain-free with the knee fused at 1 year. Conclusions: Thus, pedicled vascularized flaps are a viable alternative in the treatment of failed revision arthroplasty with large segmental bone loss. PMID:22132250
Bharti, Gaurav; Groves, Leslie; Sanger, Claire; Thompson, James; David, Lisa; Marks, Malcolm
2013-05-01
Transverse rectus abdominus muscle flaps (TRAM) can result in significant abdominal wall donor-site morbidity. We present our experience with bilateral pedicle TRAM breast reconstruction using a double-layered polypropylene mesh fold over technique to repair the rectus fascia. A retrospective study was performed that included patients with bilateral pedicle TRAM breast reconstruction and abdominal reconstruction using a double-layered polypropylene mesh fold over technique. Thirty-five patients met the study criteria with a mean age of 49 years old and mean follow-up of 7.4 years. There were no instances of abdominal hernia and only 2 cases (5.7%) of abdominal bulge. Other abdominal complications included partial umbilical necrosis (14.3%), seroma (11.4%), partial wound dehiscence (8.6%), abdominal weakness (5.7%), abdominal laxity (2.9%), and hematoma (2.9%). The TRAM flap is a reliable option for bilateral autologous breast reconstruction. Using the double mesh repair of the abdominal wall can reduce instances of an abdominal bulge and hernia.
Sakai, Yusuke; Takenaka, Shota; Matsuo, Yohei; Fujiwara, Hiroyasu; Honda, Hirotsugu; Makino, Takahiro; Kaito, Takashi
2018-06-01
This study aims to clarify the clinical potential of Hounsfield unit (HU), measured on computed tomography (CT) images, as a predictor of pedicle screw (PS) loosening, compared to bone mineral density (BMD). A total of 206 screws in 52 patients (21 men and 31 women; mean age 68.2 years) were analyzed retrospectively. The screws were classified into two groups depending on their screw loosening status on 3-month follow-up CT (loosening screw group vs. non-loosening screw group). Preoperative HU of the trajectory was evaluated by superimposing preoperative and postoperative CT images using three-dimensional image analysis software. Age, sex, body mass index, screw size, BMD of lumbar, and HU of screw trajectory were analyzed in association with screw loosening. Multivariate logistic regression analysis was performed, and the thresholds for PS loosening risk factors were evaluated using a continuous numerical variable and receiver operating characteristic (ROC) curve analyses. The area under the curve (AUC) was used to determine the diagnostic performance, and values > 0.75 were considered to represent good performance. The loosening screw group contained 24 screws (12%). Multivariate analysis revealed that the significant independent risk factors were not BMD but male sex [P = 0.028; odds ratio (OR) 2.852, 95% confidence interval (CI) 1.120-7.258] and HU of screw trajectory (P = 0.006; OR 0.989, 95% CI 0.980-0.997). ROC curve analysis demonstrated that the AUC for HU of screw trajectory for women was 0.880 (95% CI 0.798-0.961). The cutoff value was 153.5. AUC for men was 0.635 (95% CI 0.449-0.821), which was not considered to be a good performance. Low HU of screw trajectories was identified as a risk factor of PS loosening for women. For female patients with low HU, additional augmentation is recommended to prevent PS loosening. Copyright © 2018 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
[Ribeiro-Technique in Gigantomastia - Review of 294 Reduction Mammaplasties in 8 Years].
Wolter, Andreas; Pluto, Naja; Scholz, Till; Diedrichson, Jens; Arens-Landwehr, Andreas; Liebau, Jutta
2017-12-01
Reduction mammaplasty in patients with gigantomastia is challenging even to very experienced plastic surgeons. Extremely elongated pedicles impair the vascular supply of the nipple-areola complex. Breast shaping and effective reduction are difficult due to the severely stretched skin envelope. The Ribeiro technique is the standard technique for reduction mammaplasty in our clinic. The aim of this study is to review our approach in patients with gigantomastia in comparison to the current literature. From 01/2009 to 12/2016, we performed 1247 reduction mammaplasties in 760 patients. In 294 reduction mammoplasties (23.6 %), resection weight was more than 1000 g per breast corresponding to the definition of gigantomastia. The Ribeiro technique with a superomedial pedicle and inferior dermoglandular flap for autologous augmentation of the upper pole was implemented as standard procedure. In cases with a sternal notch-nipple distance > 40 cm, free nipple grafting was performed. The outcome parameters complication rate, patient satisfaction with the aesthetic result, nipple sensitivity and surgical revision rate were obtained and retrospectively analysed. In 174 patients, 294 reduction mammaplasties were performed with a resection weight of more than 1000 g per breast. Average resection weight was 1389.6 g (range, 1000-4580 g). Average age was 43.5 years (range, 18-76 years), average body mass index (BMI) was 29.2 kg/m 2 (range, 19-40 kg/m 2 ), average sternal notch-nipple distance was 34.8 cm (range, 27-52 cm), average operation time was 117 minutes (range, 72-213 minutes). A free nipple graft was necessary in 30 breasts. Overall complication rate was 7.8 %; secondary surgical revision rate was 16 %. 93 % of the patients were "very satisfied" and "satisfied" with the aesthetic result. Nipple sensitivity was rated "very good" and "good" in 88 %. The Ribeiro technique is a well established, versatile standard technique for reduction mammaplasty, which helps to create high-quality reproducible results with longterm formstable shape. In gigantomastia, this procedure is also very effective to achieve volume reduction and aesthetically pleasing results with a low complication rate. Georg Thieme Verlag KG Stuttgart · New York.
Lim, Jae-Yol; Kim, Han Su; Kim, Young-Ho; Kim, Kwang-Moon; Choi, Hong-Shik
2008-03-01
Both PMMA (polymethylmetacrylate) microspheres (PM) and stabilized hyaluronic acid (HA) are recently used for facial augmentation. The aim of this study was to test functional effect, durability, and safety of the injection of these two materials into true vocal folds, and test their availability as injection laryngoplasty materials in vivo canine model. The study was carried out with 16 beagle dogs (8 males and 8 females, average weight of 12.4 kg). No biological difference was detected between two groups; PM (Artecoll) injection and HA (Restylane) injection group. After inducing complete unilateral paralysis of the recurrent laryngeal nerve of the dogs, either PM or HA was injected into the paralyzed vocal fold. One, 3, 6, and 9 months after the injection, clinical outcomes and videostroboscopic findings were evaluated by investigators who were blind to the injection materials. Histological study and microscopic computerized augmentation dimension analysis were also performed. In HA injection group, up to 30% the HA was gradually resorbed over time. However, in PM group, the dimension of the augmented region after 9 months was similar to that after 1 month. In both groups, the mucosal waves of the vocal folds decreased in amplitude and periodicity, but they were still well detected during the follow-up periods. Acute immune reaction to HA was not detected, but some degree of foreign body reaction occurred in PM injection group. Both PM and HA are safe and relatively durable in vocal folds and they are considered as useful candidates for injection laryngoplasty.
Tan, Jane S; Roach, James W; Wang, Angela A
2011-01-01
Although the use of free vascularized fibula grafts has frequently been reported in the treatment of congenital pseudarthrosis of the tibia, the use of ipsilateral fibula graft on a vascular pedicle is uncommon. We reviewed the long-term results of this procedure in 11 patients. The records of 11 patients who underwent transfer of the ipsilateral fibula on a vascular pedicle between 2.1 and 10.8 years of age were retrospectively reviewed. Average follow-up was 11 years after the index procedure. Seven patients had reached skeletal maturity. Clinical records and radiographs were reviewed to determine patient demographics, surgical parameters, union rate, refracture rate, residual deformity, and functional outcome. Eight patients (73%) achieved union at an average of 20.1 months. Additional bone grafting procedures were required in 4 patients with distal nonunions. There were 3 refractures (38%). Four patients eventually underwent amputation, and 1 patient had a persistent nonunion at final follow-up. Residual deformity included tibial valgus and procurvatum deformities, limb length discrepancy, and ankle valgus. Use of the ipsilateral fibula did not seem to increase the risk of ankle valgus. Functional outcomes were good in all but one patient. Use of the ipsilateral fibula as a pedicle graft provides reasonable results in healing congenital pseudarthrosis of the tibia. Patients should be monitored for the sequelae of this condition, including nonunion, refracture, shortening, and angular deformity, and treated accordingly. Therapeutic Level IV.
[Pedicle flaps based on the sphenopalatine artery: anatomical and surgical study].
Gras-Cabrerizo, Juan R; Gras-Albert, Juan R; Monjas-Canovas, Irene; García-Garrigós, Elena; Montserrat-Gili, Joan R; Sánchez del Campo, Francisco; Kolanczak, Katarzyna; Massegur-Solench, Humbert
2014-01-01
Local pedicle flaps based on the sphenopalatine artery make it possible to reconstruct large defects of the skull base (SB). From January 2008 to January 2013, 64 lesions with involvement of SB were analysed. These lesions were treated using endoscopic endonasal approach and required a pedicle flap based on the sphenopalatine artery. In addition, measurements and flexibility of the flaps were examined in 4 cadaveric nasal cavities. Surgical group. Sixty-four nasoseptal flaps (NSF) were used, in 4 cases associated with a middle turbinate flap (MTF), and in 1 case supplemented with an inferior turbinate flap (ITF). Five cerebrospinal fluid fistulas (8%) were noted. Among patients with initial lesions, 7% presented an anosmia. Cadaveric group. The length of the NSF varied between 5.2 cm and 7.7 cm and the width ranged from 3 cm to 4.5 cm. The ITF provided an anterior-posterior distance between 4.2 cm and 5 cm, with a width between 1.2 cm and 2.8 cm. The mean length of MTFs varied between 3.5 cm and 4.2 cm, with a width between 1.4 cm and 1.9 cm. The most versatile local flap for the reconstruction of skull base defects is the NSF, and flaps pedicled to the posterolateral nasal artery offer an excellent alternative. Copyright © 2013 Elsevier España, S.L. y Sociedad Española de Otorrinolaringología y Patología Cérvico-Facial. All rights reserved.
Li, Xu; Zhang, Feng; Zhang, Wenzhi; Shang, Xifu; Han, Jintao; Liu, Pengfei
2017-03-01
Technique note. To report a new method for precisely controlling the depth of percutaneous pedicle screws (PPS)-without radiation exposure to surgeons and less fluoroscopy exposure to patients than with conventional methods. PPS is widely used in minimal invasive spine surgery; the advantages include reduced muscle damage, pain, and hospital stays. However, placement of PPS demands repeated checking with fluoroscopy. Thus, radiation exposure is considerable for both surgeons and patients. The PPS depth was determined by counting rotations of the screws. The distance between screw threads can be measured for particular screws; thus, full rotations of the PPS results in the screw advancing in the pedicle the distance between screw threads. To fully insert screws into the pedicle, the number of full rotations is equal to the number of threads in the PPS. We applied this technique in 58 patients with thoracolumbar fracture. The position and depth of the screws was checked during the operation with the C-arm and after operation by anteroposterior X-ray film or computed tomography. No additional procedures were required to correct the screws; we observed no neurological deficits or malpositioning of the screws. In the screw placement procedure, the radiation exposure for surgeons is zero, and the patient is well protected from extensive radiation exposure. This method of counting rotation of screws is a safe way to precisely determine the depth of PPS in the placement procedure. IV.
Endoscopic and Photodynamic Therapy of Cholangiocarcinoma
Meier, Benjamin; Caca, Karel
2016-01-01
Background Most patients with cholangiocarcinoma (CCA) have unresectable disease. Endoscopic bile duct drainage is one of the major objectives of palliation of obstructive jaundice. Methods/Results Stent implantation using endoscopic retrograde cholangiography is considered to be the standard technique. Unilateral versus bilateral stenting is associated with different advantages and disadvantages; however, a standard approach is still not defined. As there are various kinds of stents, there is an ongoing discussion on which stent to use in which situation. Palliation of obstructive jaundice can be augmented through the use of photodynamic therapy (PDT). Studies have shown a prolonged survival for the combinations of PDT and different stent applications as well as combinations of PDT and additional systemic chemotherapy. Conclusion More well-designed studies are needed to better evaluate and standardize endoscopic treatment of unresectable CCA. PMID:28229075
Endoscopic and Photodynamic Therapy of Cholangiocarcinoma.
Meier, Benjamin; Caca, Karel
2016-12-01
Most patients with cholangiocarcinoma (CCA) have unresectable disease. Endoscopic bile duct drainage is one of the major objectives of palliation of obstructive jaundice. Stent implantation using endoscopic retrograde cholangiography is considered to be the standard technique. Unilateral versus bilateral stenting is associated with different advantages and disadvantages; however, a standard approach is still not defined. As there are various kinds of stents, there is an ongoing discussion on which stent to use in which situation. Palliation of obstructive jaundice can be augmented through the use of photodynamic therapy (PDT). Studies have shown a prolonged survival for the combinations of PDT and different stent applications as well as combinations of PDT and additional systemic chemotherapy. More well-designed studies are needed to better evaluate and standardize endoscopic treatment of unresectable CCA.
Kim, Jeong Tae; Ho, Samuel Y M; Kim, Youn Hwan
2014-02-01
Postoperative flap monitoring is a vital aspect of free tissue transfer in order to detect early vascular compromise and to enable early flap salvage. The implantable Doppler monitoring system is one of many monitoring devices used to ensure accuracy and reduce unnecessary flap explorations. However, there are a number of concerns with its use, namely tension on the anastomosis, possible vessel constriction and false-negative detection. This study aimed to alleviate these concerns, by introducing a new method of placing the implantable Doppler probe on the adjacent vessel limb of a chimaeric flap. This is illustrated by a case series of chimaeric free tissue flaps that allow this surrogate placement of the Doppler probe. The flap is raised in a chimaeric fashion, with a main perforator pedicle to the skin or muscle paddle for the main reconstructive purpose and a side branch from the main pedicle going to a smaller adipofascial or muscle flap for monitoring. This branch vascular pedicle leading to the chimaeric tissue is kept sufficiently long to enable placement of the Doppler cuff and prevent turbulence. The probe of a Cook-Swartz implantable Doppler system is placed around the branch pedicle, approximately 5 mm from the branching point, and secured with a vessel clip. This is then secured away from the major vessels of the main free flap. Removal of the probe's crystal and wire is easily done with a single gentle traction on postoperative day 7. Five cases of chimaeric free flaps were performed with this manoeuvre: three thoracodorsal perforator chimaeric flaps for head-and-neck or extremity reconstruction, one latissimus dorsi neuromuscular chimaeric flap for facial reanimation and one digastric lymph node transfer for the treatment of lower limb lymphoedema. The Doppler system showed a low but sustained oscillating flow in all cases indicating vascular patency, with minimal flow interference from other large-calibre vessels. There was no discernible kinking on the anastomosis. There were no complications encountered during probe removal. This postoperative monitoring manoeuvre was done successfully with good results. The monitoring equipment is very sensitive to any flow disturbance due to positional changes in the head-and-neck region or the extremities and is able to detect flow changes in buried flaps postoperatively. Chimaeric flap composition is easier now than before because of perforator-oriented pedicle dissection, and surrogate Doppler monitoring is one more application of the chimaeric flap. This novel chimaeric fashion of implantable Doppler probe placement is a good surrogate measure of flow in the main pedicle. Copyright © 2013. Published by Elsevier Ltd.
Gao, Shutao; Lv, Zhengtao; Fang, Huang
2018-04-01
Several studies have revealed that robot-assisted technique might improve the pedicle screw insertion accuracy, but owing to the limited sample sizes in the individual study reported up to now, whether or not robot-assisted technique is superior to conventional freehand technique is indefinite. Thus, we performed this systematic review and meta-analysis based on randomized controlled trials to assess which approach is better. Electronic databases including PubMed, EMBASE, CENTRAL, ISI Web of Science, CNKI and WanFang were systematically searched to identify potentially eligible articles. Main endpoints containing the accuracy of pedicle screw implantation and proximal facet joint violation were evaluated as risk ratio (RR) and the associated 95% confidence intervals (95% CIs), while radiation exposure and surgical duration were presented as mean difference (MD) or standard mean difference (SMD). Meta-analyses were performed using RevMan 5.3 software. Six studies involving 158 patients (688 pedicle screws) in robot-assisted group and 148 patients (672 pedicle screws) in freehand group were identified matching our study. The Grade A accuracy rate in robot-assisted group was superior to freehand group (RR 1.03, 95% CI 1.00, 1.06; P = 0.04), but the Grade A + B accuracy rate did not differ between the two groups (RR 1.01, 95% CI 0.99, 1.02; P = 0.29). With regard to proximal facet joint violation, the combined results suggested that robot-assisted group was associated with significantly fewer proximal facet joint violation than freehand group (RR 0.07, 95% CI 0.01, 0.55; P = 0.01). As was the radiation exposure, our findings suggested that robot-assisted technique could significantly reduce the intraoperative radiation time (MD - 12.38, 95% CI - 17.95, - 6.80; P < 0.0001) and radiation dosage (SMD - 0.64, 95% CI - 0.85, - 0.43; P < 0.00001). But the overall surgical duration was longer in robot-assisted group than conventional freehand group (MD 20.53, 95% CI 5.17, 35.90; P = 0.009). The robot-assisted technique was associated with equivalent accuracy rate of pedicle screw implantation, fewer proximal facet joint violation, less intraoperative radiation exposure but longer surgical duration than freehand technique. Powerful evidence relies on more randomized controlled trials with high quality and larger sample size in the future.
Schittkowski, M P; Guthoff, R F
2006-01-01
Background/aim Children with congenital microphthalmos are usually able to wear an eye prosthesis but the cosmetic aspect is determined by the size of the orbital volume deficiency. Instead of using a ball shaped standard hydrogel expander or a regular orbital implant, which would necessitate enucleation of the microphthalmic eye, this study investigates the feasibility of volume augmentation with injectable pellet expanders, as formerly suggested for acquired anophthalmos in adults only. Method The pellet expander is made from a self inflating hydrogel that takes up water by osmosis (dry state: length 8 mm, diameter 2 mm, volume 0.025 ml; in vitro hydrated state after around 1 day: length 15 mm, diameter 4 mm, volume 0.24 ml; swelling capacity: 9.6‐fold). This report concerns six patients (two girls and four boys) aged between 4 months and 42 months with unilateral microphthalmos who were treated by injection of 4–14 pellet expanders into the retrobulbar orbital tissue. Volume augmentation was 1–3.5 ml. The pellets were injected using a customised trocar and placed behind the microphthalmos directed into the intraconal space. Results The increasing orbital volume was noticeable within 2 days and was confirmed by ultrasonography and magnetic resonance imaging. The final result can be anticipated by the volume augmentation effect produced by the amount of saline solution injected in the orbital apex region. All patients were fitted with an artificial eye, which was subsequently enlarged every 3–5 months. Anophthalmic enophthalmos was fully compensated with this technique. No complications have been encountered to date. Conclusions Orbital volume augmentation with injectable self inflating hydrogel expander pellets is apparently a safe, quick, and minimally invasive technique for various indications in orbital reconstructive surgery—for example, to treat an enophthalmic appearance in microphthalmos and congenital or acquired anophthalmos. PMID:16707526
Pedicled omental onlay flap for post-traumatic intrahepatic major ductal injury.
Ratan, Simmi K; Gangurde, Anita; Sinha, Shandip K; Singh, Sudhir; Sharma, Barjesh Chander; Aggarwal, Satish K
2013-01-01
We report a 5-year-old girl who presented with post traumatic biliary leakage that failed to respond to conservative management for two weeks. Surgical exploration in the third week revealed a partially healed 5 cm long hepatic laceration in the right lobe of the liver. Bile was found leaking through a rent in the major right intra-hepatic duct at the apex of liver laceration. A pedicled onlay omental flap was used to buttress this rent as direct closure was not possible due to friable tissue. The child recovered uneventfully.
Berezovsky, Alexander Bogdanov; Pagkalos, Vasileios A; Shoham, Yaron; Krieger, Yuval; Silberstein, Eldad
2015-08-01
Breast reconstruction has become standard of care for female patients with breast cancer. The transverse rectus abdominis musculo-cutaneous flap (TRAMf) is the most common method of immediate or delayed autologous breast reconstruction following mastectomy. We share our experience with modified, double back cut of post-mastectomy skin in delayed pedicled TRAMf breast reconstruction, resulting in fish-shaped skin paddle. This sort of back cut is a simple, reliable way to obtain a natural, esthetically pleasant breast mound with inconspicuous hidden scars.
Yeo, S; Perrot, P; Duteille, F
2010-04-01
The realization of free flaps with lack of reliable vessels nearby the loss of substance is a difficult problem for plastic surgeons. We report 10 cases of free tissue transfers with a one-stage technique lengthening the vascular pedicle of the free flap with interpositional vein grafts. Taking into consideration the good results and the low rate of morbidity, the authors emphasize the use of this technique rather than a two-stage procedure. Copyright 2009 Elsevier Masson SAS. All rights reserved.
Firszt, Jill B; Reeder, Ruth M; Holden, Laura K
At a minimum, unilateral hearing loss (UHL) impairs sound localization ability and understanding speech in noisy environments, particularly if the loss is severe to profound. Accompanying the numerous negative consequences of UHL is considerable unexplained individual variability in the magnitude of its effects. Identification of covariables that affect outcome and contribute to variability in UHLs could augment counseling, treatment options, and rehabilitation. Cochlear implantation as a treatment for UHL is on the rise yet little is known about factors that could impact performance or whether there is a group at risk for poor cochlear implant outcomes when hearing is near-normal in one ear. The overall goal of our research is to investigate the range and source of variability in speech recognition in noise and localization among individuals with severe to profound UHL and thereby help determine factors relevant to decisions regarding cochlear implantation in this population. The present study evaluated adults with severe to profound UHL and adults with bilateral normal hearing. Measures included adaptive sentence understanding in diffuse restaurant noise, localization, roving-source speech recognition (words from 1 of 15 speakers in a 140° arc), and an adaptive speech-reception threshold psychoacoustic task with varied noise types and noise-source locations. There were three age-sex-matched groups: UHL (severe to profound hearing loss in one ear and normal hearing in the contralateral ear), normal hearing listening bilaterally, and normal hearing listening unilaterally. Although the normal-hearing-bilateral group scored significantly better and had less performance variability than UHLs on all measures, some UHL participants scored within the range of the normal-hearing-bilateral group on all measures. The normal-hearing participants listening unilaterally had better monosyllabic word understanding than UHLs for words presented on the blocked/deaf side but not the open/hearing side. In contrast, UHLs localized better than the normal-hearing unilateral listeners for stimuli on the open/hearing side but not the blocked/deaf side. This suggests that UHLs had learned strategies for improved localization on the side of the intact ear. The UHL and unilateral normal-hearing participant groups were not significantly different for speech in noise measures. UHL participants with childhood rather than recent hearing loss onset localized significantly better; however, these two groups did not differ for speech recognition in noise. Age at onset in UHL adults appears to affect localization ability differently than understanding speech in noise. Hearing thresholds were significantly correlated with speech recognition for UHL participants but not the other two groups. Auditory abilities of UHLs varied widely and could be explained only in part by hearing threshold levels. Age at onset and length of hearing loss influenced performance on some, but not all measures. Results support the need for a revised and diverse set of clinical measures, including sound localization, understanding speech in varied environments, and careful consideration of functional abilities as individuals with severe to profound UHL are being considered potential cochlear implant candidates.
Dumpa, Srikanth Reddy; Shetty, Ajoy Prasad; Aiyer, Siddharth N; Kanna, Rishi Mugesh; Rajasekaran, S
2018-04-01
Retrospective observational study. To analyze the effect of low-density (LD) strategic pedicle screw fixation on the correction of coronal and sagittal parameters in adolescent idiopathic scoliosis (AIS) patients. LD screw fixation achieves favorable coronal correction, but its effect on sagittal parameters is not well established. AIS is often associated with decreased thoracic kyphosis (TK), and the use of multi-level pedicle screws may result in further flattening of the sagittal profile. A retrospective analysis was performed on 92 patients with AIS to compare coronal and sagittal parameters preoperatively and at 2-year follow-up. All patients underwent posterior correction via LD strategic pedicle screw fixation. Radiographs were analyzed for primary Cobb angle (PCA), coronal imbalance, cervical sagittal angle (CSA), TK, lumbar lordosis (LL), pelvic incidence, pelvic tilt (PT), sacral slope (SS), C7 plumb line, spino-sacral angle, curve flexibility, and screw density. PCA changed significantly from 57.6°±13.9° to 19°±8.4° ( p <0.0001) with 67% correction, where the mean curve flexibility was 41% and screw density was 68%. Regional sagittal parameters did not change significantly, including CSA (from 10.76° to 10.56°, p =0.893), TK (from 24.4° to 22.8°, p =0.145), and LL (from 50.3° to 51.1°, p =0.415). However, subgroup analysis of the hypokyphosis group (<10°) and the hyperkyphosis group (>40°) showed significant correction of TK ( p <0.0001 in both). Sacro-pelvic parameters showed a significant decrease of PT and increase of SS, suggesting a reduction in pelvic retroversion SS (from 37° to 40°, p =0.0001) and PT (from 15° to 14°, p =0.025). LD strategic pedicle screw fixation provides favorable coronal correction and improves overall sagittal sacro-pelvic parameters. This technique does not cause significant flattening of TK and results in a favorable restoration of TK in patients with hypokyphosis or hyperkyphosis.
Dumpa, Srikanth Reddy; Aiyer, Siddharth N.; Kanna, Rishi Mugesh; Rajasekaran, S
2018-01-01
Study Design Retrospective observational study. Purpose To analyze the effect of low-density (LD) strategic pedicle screw fixation on the correction of coronal and sagittal parameters in adolescent idiopathic scoliosis (AIS) patients. Overview of Literature LD screw fixation achieves favorable coronal correction, but its effect on sagittal parameters is not well established. AIS is often associated with decreased thoracic kyphosis (TK), and the use of multi-level pedicle screws may result in further flattening of the sagittal profile. Methods A retrospective analysis was performed on 92 patients with AIS to compare coronal and sagittal parameters preoperatively and at 2-year follow-up. All patients underwent posterior correction via LD strategic pedicle screw fixation. Radiographs were analyzed for primary Cobb angle (PCA), coronal imbalance, cervical sagittal angle (CSA), TK, lumbar lordosis (LL), pelvic incidence, pelvic tilt (PT), sacral slope (SS), C7 plumb line, spino-sacral angle, curve flexibility, and screw density. Results PCA changed significantly from 57.6°±13.9° to 19°±8.4° (p <0.0001) with 67% correction, where the mean curve flexibility was 41% and screw density was 68%. Regional sagittal parameters did not change significantly, including CSA (from 10.76° to 10.56°, p =0.893), TK (from 24.4° to 22.8°, p =0.145), and LL (from 50.3° to 51.1°, p =0.415). However, subgroup analysis of the hypokyphosis group (<10°) and the hyperkyphosis group (>40°) showed significant correction of TK (p <0.0001 in both). Sacro-pelvic parameters showed a significant decrease of PT and increase of SS, suggesting a reduction in pelvic retroversion SS (from 37° to 40°, p =0.0001) and PT (from 15° to 14°, p =0.025). Conclusions LD strategic pedicle screw fixation provides favorable coronal correction and improves overall sagittal sacro-pelvic parameters. This technique does not cause significant flattening of TK and results in a favorable restoration of TK in patients with hypokyphosis or hyperkyphosis. PMID:29713412
Bi-Pedicle Fixation of Affected Vertebra in Thoracolumbar Burst Fracture.
Padalkar, Pravin; Mehta, Varshil
2017-04-01
Burst fractures of the spine account for 14% of all spinal injuries and more than 50% of all thoracolumbar trauma. However, there is ambiguity while choosing the right treatment plan. Short Segment Pedicle screw Fixation (SSPF) has become an increasingly popular method of treatment of thoracolumbar burst fractures, providing the advantage of incorporating fewer motion segments in the fixation. Various biomechanical studies showed that the use of pedicle screws could achieve stable construct within short-segment fixation. To evaluate the efficacy of SSPF using longest possible screws in both pedicles of fractured vertebra. A retrospective chart review of 25 single burst thoracolumbar fracture patients, operated between May 2009 to 2015 in a tertiary care trauma center, was conducted. Preoperative and post-operative plain radiographs were evaluated for kyphotic angulations using the traditional Cobb method. Anterior Vertebral Height (AVH), Posteriors Vertebral Height (PVH) were measured preoperatively and immediate postoperatively. Average percentage loss of AVH and mid-sagittal height were calculated on preoperative and postoperative X-rays on follow up. Fourteen men and 11 women with an average age of 42.92 years comprised the study population. Mean age at the time of operation was 34.5±14.2 years. Mean operation time was 168±72 (minutes). Average hospitalization time was 9±7 (days). Mean blood loss was 515±485 (ml). There were two cases of postoperative infection and implant failure each. A mean of 15.2° of kyphosis correction was attained from pre-operation to post-operation (p<0.0001). Although, there was a 15° average improvement of kyphosis post-fixation, loss of correction over time was nearly 8°, resulting in a 7° mean correction of kyphosis. A mean loss of AVH on postoperative radiograph was 6.12% and maintained 12.4% at the time of review (p<0.001). Similarly, there was 32.8% mid-sagittal height loss at time of injury, which was improved to only 12.6% as compare to initial height loss (p<0.0001). In this study, we propose SSPF using longest possible screws in both pedicle of fractured vertebra. Bi-pedicular fixation gives significant radiological corrections.
Viljoen, Stephanus V; DeVries Watson, Nicole A; Grosland, Nicole M; Torner, James; Dalm, Brian; Hitchon, Patrick W
2014-10-01
The objective of this study was to evaluate the biomechanical properties of lateral instrumentation compared with short- and long-segment pedicle screw constructs following an L-1 corpectomy and reconstruction with an expandable cage. Eight human cadaveric T10-L4 spines underwent an L-1 corpectomy followed by placement of an expandable cage. The spines then underwent placement of lateral instrumentation consisting of 4 monoaxial screws and 2 rods with 2 cross-connectors, short-segment pedicle screw fixation involving 1 level above and below the corpectomy, and long-segment pedicle screw fixation (2 levels above and below). The order of instrumentation was randomized in the 8 specimens. Testing was conducted for each fixation technique. The spines were tested with a pure moment of 6 Nm in all 6 degrees of freedom (flexion, extension, right and left lateral bending, and right and left axial rotation). In flexion, extension, and left/right lateral bending, posterior long-segment instrumentation had significantly less motion compared with the intact state. Additionally, posterior long-segment instrumentation was significantly more rigid than short-segment and lateral instrumentation in flexion, extension, and left/right lateral bending. In axial rotation, the posterior long-segment construct as well as lateral instrumentation were not significantly more rigid than the intact state. The posterior long-segment construct was the most rigid in all 6 degrees of freedom. In the setting of highly unstable fractures requiring anterior reconstruction, and involving all 3 columns, long-segment posterior pedicle screw constructs are the most rigid.
Shark island pedicle flap for repair of combined nasal ala-perialar defects.
Cvancara, Joseph L; Wentzell, J Michael
2006-05-01
The combined nasal ala-perialar defect involving the concave intersection of the lateral nasal ala, nasal sidewall, cheek, and upper cutaneous lip is a problem for reconstructive surgery. During repair of combined cheek and nose defects, it is important not to blunt the alar facial sulcus. Defects involving these adjacent cosmetic units can be repaired by using combination procedures such as a flap/graft. Our purpose is to introduce, describe, and illustrate a one-stage flap repair descriptively named the "shark" island pedicle flap (SIPF). The SIPF was developed for a specific combined nasal ala-perialar defect. This reconstruction restores the natural contours, preserves cosmetic boundaries, and eliminates the need for pexing sutures and graft/flap combinations. The SIPF is an island pedicle flap with a superior arm that rotates 90 degrees into the wound. This arm repairs the alar portion of the defect. The advancing island pedicle flap repairs the alar facial sulcus. The 90 degrees rotation of the superior arm forces the alar portion of the flap to tilt 90 degrees relative to the remaining body of the flap, forming an inverted cone of redundancy. Natural re-creation of the lateral ala and the alar facial sulcus results. Illustrative examples with a descriptive technique are provided for the SIPF. A well-planned SIPF reconstruction can provide exceptional cosmetic and functional results. Cutaneous reconstructive surgeons will find the SIPF useful and reproducible in their armamentarium for single-stage aesthetic and functional repair of a specific combined lateral ala-adjacent perialar tissue defect.
Kostro, Justyna; Jankau, Jerzy; Bigda, Justyna; Skorek, Andrzej
2014-01-01
The number of breast reconstruction procedures has been increasing in recent years. One of the suggested treatment methods is breast reconstruction with a pedicled skin and muscle TRAM flap (transverse rectus abdominis muscle – TRAM). Surgical incisions performed during a cholecystectomy procedure may be located in the areas significant for flap survival. The aim of this paper is to present anatomical changes in abdominal walls secondary to pedicled skin and muscle (TRAM) flap breast reconstruction, which influence the planned access in cholecystectomy procedures. The authors present 2 cases of cholecystectomy performed due to cholelithiasis in female patients with a history of TRAM flap breast reconstruction procedures. The first patient underwent a traditional method of surgery 14 days after the reconstruction due to acute cholecystitis. The second patient underwent a laparoscopy due to cholelithiasis 7 years after the TRAM procedure. In both cases an abdominal ultrasound scan was performed prior to the operation, and surgical access was determined following consultation with a plastic surgeon. The patient who had undergone traditional cholecystectomy developed an infection of the postoperative wound. The wound was treated with antibiotics, vacuum therapy and skin grafting. After 7 weeks complete postoperative wound healing and correct healing of the TRAM flap were achieved. The patient who had undergone laparoscopy was discharged home on the second postoperative day without any complications. In order to plan a safe surgical access, it is necessary to know the changes in the anatomy of abdominal walls following a pedicled TRAM flap breast reconstruction procedure. PMID:25337177
[Longitudinal preputial pedicled flap urethroplasty for chordee of Donnahoo type IV].
Zeng, Li; Shan, Wei; Yuan, Miao; Huang, Guizhen; Huang, Lugang
2012-11-01
To investigate the effectiveness of longitudinal preputial pedicled flap urethroplasty for chordee of Donnahoo IV type. Between June 1994 and October 2011, 30 patients with chordee (Donnahoo type IV) underwent longitudinal preputial pedicled flap urethroplasty. The patients' age ranged from 2 to 16 years (mean, 5.8 years). The morphology of the balanus-navicular fossa-external urethral orifice ranged normal; the penis length was 2.5-6.8 cm (mean, 4.3 cm); the penis bending angle was 35-70 degrees (mean, 40.1 degrees). Primary and secondary operation was 27 cases and 3 cases, respectively. The size of flap ranged from 1.5 cm x 1.3 cm to 4.0 cm x 2.0 cm. After correction, the penis length was 3.0-8.5 cm (mean, 6.6 cm); the penis bending angle was 0-10 degrees (mean, 1.2 degrees). All patients were followed up 6 months to 12 years (mean, 33 months). No recurrence, stabbing pain of the balanus, or foreign body sensation occurred during follow-up. Of them, 4 patients (13.33%) had urinary fistular, they had satisfactory results after the second operation; 2 patients (6.67%) had urethral stricture 1 month after operation, they also had satisfactory results after arethral dilatation. The other patients showed no scattering urinary flow and good direction without complication. Six patients had satisfactory sexual function after puberty without erection disorder, pain, or dyspareunia. Longitudinal preputial pedicled flap urethroplasty can achieve maximum utilization of prepuce and aesthetic and functional improvement with less complication, so it is a relatively ideal mean for treating chordee of Donnahoo type IV.
In vitro biomechanical comparison of pedicle screws, sublaminar hooks, and sublaminar cables.
Hitchon, Patrick W; Brenton, Matthew D; Black, Andrew G; From, Aaron; Harrod, Jeremy S; Barry, Christopher; Serhan, Hassan; Torner, James C
2003-07-01
Three types of posterior thoracolumbar implants are in use today: pedicle screws, sublaminar titaniumcables, and sublaminar hooks. The authors conducted a biomechanical comparison of these three implants in human cadaveric spines. Spine specimens (T5-12) were harvested, radiographically assessed for fractures or metastases, and their bone mineral density (BMD) was measured. Individual vertebrae were disarticulated and fitted with either pedicle screws, sublaminar cables, or bilateral claw hooks. The longitudinal component of each construct consisted of bilateral 10-cm rods connected with two cross-connectors. The vertebral body was embedded in cement, and the rods were affixed to a ball-and-socket apparatus for the application of a distraction force. The authors analyzed 1) 20 vertebrae implanted with screws; 2) 20 with hooks, and 3) 20 with cables. The maximum pullout (MPO) forces prior to failure (mean +/- standard deviation) for the screw, hook, and cable implants were 972 +/- 330, 802 +/- 356, and 654 +/- 248 N, respectively (p = 0.0375). Cables allowed significantly greater displacement (6.80 +/- 3.95 mm) prior to reaching the MPO force than hooks (3.73 +/- 1.42 mm) and screws (4.42 +/- 2.15 mm [p = 0.0108]). Eleven screw-implanted vertebrae failed because of screw pullout. All hook-and-cable-implanted vertebrae failed because of pedicle, middle column, or laminar fracture. These findings suggest that screws possess the greatest pullout strength of the three fixation systems. Sublaminar cables are the least rigid of the three. When screw failure occurred, the mechanism was generally screw back-out, without vertebral fractures.
Satarasinghe, Praveen; Hamilton, Kojo D; Tarver, Michael J; Buchanan, Robert J; Koltz, Michael T
2018-04-17
Utilization of pedicle screws (PS) for spine stabilization is common in spinal surgery. With reliance on visual inspection of anatomical landmarks prior to screw placement, the free-hand technique requires a high level of surgeon skill and precision. Three-dimensional (3D), computer-assisted virtual neuronavigation improves the precision of PS placement and minimization steps. Twenty-three patients with degenerative, traumatic, or neoplastic pathologies received treatment via a novel three-step PS technique that utilizes a navigated power driver in combination with virtual screw technology. (1) Following visualization of neuroanatomy using intraoperative CT, a navigated 3-mm match stick drill bit was inserted at an anatomical entry point with a screen projection showing a virtual screw. (2) A Navigated Stryker Cordless Driver with an appropriate tap was used to access the vertebral body through a pedicle with a screen projection again showing a virtual screw. (3) A Navigated Stryker Cordless Driver with an actual screw was used with a screen projection showing the same virtual screw. One hundred and forty-four consecutive screws were inserted using this three-step, navigated driver, virtual screw technique. Only 1 screw needed intraoperative revision after insertion using the three-step, navigated driver, virtual PS technique. This amounts to a 0.69% revision rate. One hundred percent of patients had intraoperative CT reconstructed images taken to confirm hardware placement. Pedicle screw placement utilizing the Stryker-Ziehm neuronavigation virtual screw technology with a three step, navigated power drill technique is safe and effective.
Zhong, Wanrun; Lu, Shengdi; Wang, Chunyang; Wen, Gen; Han, Pei; Chai, Yimin
2017-07-01
The lack of soft tissue that is available for medial leg and foot defect reconstructions presents a challenge for plastic surgeons. The saphenous neurofasciocutaneous perforator flap application presents an effective alternative to local flap transfers. However, the venous flow and pedicle twisting problems are still disputed. Here, we present our experiences with modified cutaneous pedicles with a single perforator pedicle, which improves the venous flow and the pedicle twisting problem. This study was conducted from June 2007 through September 2011, and a total of 15 patients with lower medial leg and foot defects were included. There were 11 men and four women. An asymmetric 'propeller' flap was planned around a perforator that was adjacent to the defects, which was preoperatively confirmed by Doppler. The perforator was sufficiently dissociated to allow for the flap to be turned towards the defects. We preserved some distal skin and subcutaneous tissue from the short side of the 'propeller' to cover some donor site regions, and other regions were covered with split thickness skin grafts. The follow-up period ranged from 3 to 12 months. An infection occurred in one case. Partial flap necrosis was noted in two cases. The other 12 flaps completely survived and matched the recipient sites with regard to colour, texture and thickness. The single perforator greater saphenous neuro-veno-fasciocutaneous propeller flap is an effective solution for medial leg and foot defects, and it has a large rotation arc and a satisfactory aesthetic result. © 2015 Royal Australasian College of Surgeons.
Sun, Qing-peng
2015-05-01
To investigate application of the bone flap pedicled on the retrograde branch of radial artery for treatment of old scaphoid bone fractures of type AO-B. From October 2007 to October 2011,41 patients with old scaphoid bone fractures of type AO-B were treated by transplantation of the bone flap pedicled on the retrograde branch of radial artery including 26 males and 15 females with an average of (27.3±4.5) years old ranging from 16 to 43 years old. The courses before operation ranged from 6 to 22 months with an average of 11 months. All fractures belonged to the type B of AO classification, that is old wrist fracture of scaphoid bone. All patients' wrist function (pain, function, motion, grip strength) were evaluated by Cooney's modifiedwrist scoring system before and 6 months after operation,and the conditions of bone healing were observed during the follow-up time. Among them, 36 patients were followed up from 4 to 15 months with an average of 8.3 months. The wounds were healed well without other complications as infection appearing. X-rays or CT confirmed that all fractures were healed completely. The Cooney wrist score was improved from preoperative 53.61±13.97 to postoperative 81.81±8.71 (P<0.01). The operation of transplantation of the bone flap pedicled on the retrograde branch of radial artery is an effective method to treat old scaphoid bone fractures,which is scientific and has curative effects, and valuable for clinical application.
Yang, Yong-Jun; Zhang, En-Zhong; Tan, Yuan-Chao; Zhou, Ji-Ping; Yao, Shu-Qiang; Jiang, Chuan-Jie; Cong, Pei-Yan
2009-11-01
To investigate the clinical effect of atlantoaxial pedicle screw internal fixation for treatment of atlantoaxial dislocation. Sixteen patients with atlantoaxial dislocation were treated from Dec. 2005 to June 2007, included 10 males and 6 females, aged from 38 to 45 years old (means 40.5 years). Among them 12 patients combined with nerve injury, according to ASIA grade: there were 3 cases in grade B, 5 cases in grade C, 4 cases in grade D. All patients received preoperative CT, radiograph and skull traction. Intraoperative posterior approach general spine pedicle screw-rod orthopaedics fixation system used and iliac bone block were implanted in space of posterior atlantal arch and axial vertebral plate. The outcome and complications were observed in the near future. There was no vascular or neural injury found. The patients were followed up for 12 to 24 months (means 18 months). All head pain, acid storm symptoms were improved after operation. According to the Odom's clinical efficacy evaluation standard, 12 cases were excellent, 4 were good. Eleven cases of 12 with nerve injury recovered significantly. By ASIA classification: 1 cases was in grade B, 2 cases were in grade C, 5 cases were in grade D, 4 cases were in grade E. No looseness or breakage of screw occurred. Bony fusion was achieved in all cases. Posterior approach atlantoaxial pedicle screw internal fixation have the advantages of direct screw placement, short-segment fusion, intraoperative reduction, fixation reliable, high fusion rate, and it can restablish the upper cervical vertebrae stability and help to recover the spinal cord and nerve function.
Asʼadi, Kamran; Salehi, Seyed Hamid; Shoar, Saeed
2017-01-01
Distally based fasciocutaneous sural flap is popular in the reconstruction of distal leg and foot burns. However, utilization of this technique in high-voltage electrical injury has been challenging. The present study aimed to compare the outcome of early aggressive debridement and coverage of contact point of acute high-voltage electrical injury using distally based fasciocutaneous sural flap between high-risk and low-risk patients defined by the anatomic proximity of the flap pedicle to the zone of injury. A total of 51 patients with contact point of high-voltage electrical burn (HVEB) in distal leg and foot undergoing distally based fasciocutaneous sural flap were included in this prospective clinical study. In 28 patients, the flap pedicle was not involved in the contact point of high-voltage electrical injury (low risk/control group), whereas in 21 patients, it was located inside the zone of injury (high-risk/case group). Patients were followed up for a median of 21 months (range, 12-44 months). Wound dimensions to be covered were relatively similar between the 2 groups. Complications of flap survival (primary outcome) and other minor early and late complications (secondary outcome) did not significantly differ between the 2 groups (P > 0.05). Provided that early and completed debridements of contact points of HVEB were achieved, distally based sural flap is feasible and there is reliable coverage in HVEB even in patients with flap pedicle located in vicinity of the zone of injury.
Stirling, Aaron D; Murray, Conor P; Lee, Mark A
2017-10-01
To investigate the blood supply to the nipple areola complex (NAC) on thoracic CT angiograms (CTA) to improve breast pedicle design in reduction mammoplasty. In a single centre, CT scans of the thorax were retrospectively reviewed for suitability by a cardiothoracic radiologist. Suitable scans had one or both breasts visible in extended fields, with contrast enhancement of breast vasculature in a female patient. The arterial sources, intercostal space perforated, glandular/subcutaneous course, vessel entry point, and the presence of periareolar anastomoses were recorded for the NAC of each breast. From 69 patients, 132 breasts were suitable for inclusion. The most reproducible arterial contribution to the NAC was perforating branches arising from the internal thoracic artery (ITA) (n = 108, 81.8%), followed by the long thoracic artery (LTA) (n = 31, 23.5%) and anterior intercostal arteries (AI) (n = 21, 15.9%). Blood supply was superficial versus deep in (n = 86, 79.6%) of ITA sources, (n = 28, 90.3%) of LTA sources, and 10 (47.6%) of AI sources. The most vascularly reliable breast pedicle would be asymmetrical in 7.9% as a conservative estimate. We suggest that breast CT angiography can provide valuable information about NAC blood supply to aid customised pedicle design, especially in high-risk, large-volume breast reductions where the risk of vascular-dependent complications is the greatest and asymmetrical dominant vasculature may be present. Superficial ITA perforator supplies are predominant in a majority of women, followed by LTA- and AIA-based sources, respectively.
Accuracy of image-guided surgical navigation using near infrared (NIR) optical tracking
NASA Astrophysics Data System (ADS)
Jakubovic, Raphael; Farooq, Hamza; Alarcon, Joseph; Yang, Victor X. D.
2015-03-01
Spinal surgery is particularly challenging for surgeons, requiring a high level of expertise and precision without being able to see beyond the surface of the bone. Accurate insertion of pedicle screws is critical considering perforation of the pedicle can result in profound clinical consequences including spinal cord, nerve root, arterial injury, neurological deficits, chronic pain, and/or failed back syndrome. Various navigation systems have been designed to guide pedicle screw fixation. Computed tomography (CT)-based image guided navigation systems increase the accuracy of screw placement allowing for 3- dimensional visualization of the spinal anatomy. Current localization techniques require extensive preparation and introduce spatial deviations. Use of near infrared (NIR) optical tracking allows for realtime navigation of the surgery by utilizing spectral domain multiplexing of light, greatly enhancing the surgeon's situation awareness in the operating room. While the incidence of pedicle screw perforation and complications have been significantly reduced with the introduction of modern navigational technologies, some error exists. Several parameters have been suggested including fiducial localization and registration error, target registration error, and angular deviation. However, many of these techniques quantify error using the pre-operative CT and an intra-operative screenshot without assessing the true screw trajectory. In this study we quantified in-vivo error by comparing the true screw trajectory to the intra-operative trajectory. Pre- and post- operative CT as well as intra-operative screenshots were obtained for a cohort of patients undergoing spinal surgery. We quantified entry point error and angular deviation in the axial and sagittal planes.
Li, Chun-Chang; Chang, Shun-Cheng; Fu, Ju-Peng; Tzeng, Yuan-Sheng; Wang, Chih-Hsing; Chen, Tim-Mo; Chen, Shyi-Gen
2013-12-01
Surgical reconstruction of trochanteric sores remains a formidable task for plastic surgeons. Diverse types of flaps have been proposed for use in this situation, each with particular advantages and limitations. This study aimed to compare the surgical outcomes between the hatchet-shaped tensor fascia lata (TFL) flap and the pedicle anterior lateral thigh (ALT) flap in treatment of trochanteric sores. Forty-eight patients with trochanteric sores were operated on under spinal or general anesthesia using TFL or ALT flaps between August 2007 and November 2010. In the TFL group, 26 hatchet-shaped TFL musculocutaneous flaps were performed on 24 patients. In the ALT group, 25 pedicle ALT musculocutaneous flaps were performed on 24 patients. Surgical outcomes were retrospectively analyzed. No significant difference was detected between the TFL and ALT groups in terms of age, preoperative disease period, obesity (body mass index), American Society of Anesthesiologists score, comorbidity, the defect size, follow-up time, and complication rate. The recurrence rate and the flap size were significantly higher in the TFL group than in the ALT group (P = 0.022; P < 0.001). The operation time was longer in the ALT group (P < 0.001). The pedicle ALT flap is a more effective treatment than the TFL flap for the surgical management of trochanteric sores. The hatchet-shaped TFL flap should be reserved for the reconstruction of recurrent trochanteric sores or for use in the critically ill patient who cannot tolerate longer anesthesia and operation time.
Newman, Martin I; Samson, Michel C; Tamburrino, Joseph F; Swartz, Kimberly A; Brunworth, Louis
2011-01-01
Pedicle transverse rectus abdominus myocutaneous (pTRAM) flaps remain the most common method of autologous tissue breast reconstruction. Using pTRAM flaps, complications often arise postoperatively, secondary to inadequate circulation. Tissues from distant angiosomes are associated with poorer perfusion, but this differs among patients. Many modalities have been used to reduce the risk of complications, but none have achieved widespread application. The authors believe that laser-assisted indocyanine green fluorescent dye angiography (LA-ICGA) can potentially reduce the risk of complications. In two routine, single-pedicle, ipsilateral pTRAM flaps, LA-ICGA imaging was performed following the division of the distal rectus muscle and deep inferior epigastric pedicle. The resulting images were used to guide design of the flap and debridement. In case 1, good perfusion was observed in zone 1 and part of zone 2. In case 2, good perfusion was observed in zone 1 and 50% of zone 3, with little perfusion in zone 2. In both cases, tissues with poor perfusion were debrided before transfer and inset. In both patients, there were no issues with wound healing, tissue necrosis or fat necrosis. The variability of perfusion of the pTRAM flap among individuals is well appreciated. LA-ICGA helped to determine the limits of good perfusion and, therefore, the limits of tissue to be preserved for transfer and inset. This helped to avoid harvesting poorly perfused tissue that would have almost certainly experienced necrosis and, ultimately, would have reduced the risk of postoperative complications.
Newman, Martin I; Samson, Michel C; Tamburrino, Joseph F; Swartz, Kimberly A; Brunworth, Louis
2011-01-01
BACKGROUND: Pedicle transverse rectus abdominus myocutaneous (pTRAM) flaps remain the most common method of autologous tissue breast reconstruction. Using pTRAM flaps, complications often arise postoperatively, secondary to inadequate circulation. Tissues from distant angiosomes are associated with poorer perfusion, but this differs among patients. Many modalities have been used to reduce the risk of complications, but none have achieved widespread application. The authors believe that laser-assisted indocyanine green fluorescent dye angiography (LA-ICGA) can potentially reduce the risk of complications. METHODS: In two routine, single-pedicle, ipsilateral pTRAM flaps, LA-ICGA imaging was performed following the division of the distal rectus muscle and deep inferior epigastric pedicle. The resulting images were used to guide design of the flap and debridement. RESULTS: In case 1, good perfusion was observed in zone 1 and part of zone 2. In case 2, good perfusion was observed in zone 1 and 50% of zone 3, with little perfusion in zone 2. In both cases, tissues with poor perfusion were debrided before transfer and inset. In both patients, there were no issues with wound healing, tissue necrosis or fat necrosis. CONCLUSIONS: The variability of perfusion of the pTRAM flap among individuals is well appreciated. LA-ICGA helped to determine the limits of good perfusion and, therefore, the limits of tissue to be preserved for transfer and inset. This helped to avoid harvesting poorly perfused tissue that would have almost certainly experienced necrosis and, ultimately, would have reduced the risk of postoperative complications. PMID:22379372
Lazzeri, Davide; Huemer, Georg M.; Nicoli, Fabio; Larcher, Lorenz; Dashti, Talal; Grassetti, Luca; Li, Qingfeng; Spinelli, Giuseppe; Agostini, Tommaso
2013-01-01
Background The aim of this investigation was to systematically review the current literature to provide the best data for indications, outcomes, survival, and complication rates of pedicled propeller perforator flaps for upper body defects. Methods A comprehensive literature review for articles published from January 1991 to December 2011 was performed using the PubMed, Medline, and Cochrane Databases. Articles without available full-text, single case reports or papers with excessive missing data were excluded. Papers reporting pedicle-perforator (propeller) flaps used for lower extremity reconstruction were excluded from meta-analysis. Results From the initial 1,736 studies our search yielded, 343 studies qualified for the second stage of selection. Of 117 full-text reports screened, 41 studies, met the definitive inclusion and exclusion criteria. Of the selected 41 articles, 26 were case series, original papers or retrospective reviews and were included, whereas 15 were case report papers and therefore were excluded. Two hundred ninety-five propeller flaps were reported to have been used in a total of 283 patients. Indications include repair of trauma-induced injuries, post-trauma revision surgery, cancer resection, chronic infection, pressure sores, and chronic ulcers with a major complication rate (3.3%) comparable to that of free flaps. No specific exclusion criteria for the procedure were presented in the studies reviewed. Conclusions Pedicled propeller flaps are a versatile and safe reconstructive option that are easy and quick to raise and that provide unlimited clinical solutions because of the theoretical possibility of harvesting them based on any perforator chosen among those classified in the body. PMID:23362479
Xu, Yue-Min; Zhang, Xin-Ru; Xie, Hong; Song, Lu-Jie; Feng, Chao; Fei, Xiao-Fang
2014-03-01
Male urinary incontinence is relatively common complication of radical prostatectomy and of posterior urethroplasty following traumatic pelvic fracture. Here, we investigate the use of pedicled rectus abdominis muscle and fascia flap sling of the bulbar urethra for treatment for male-acquired urinary incontinence. Ten patients with acquired urinary incontinence were included in the study. Urinary incontinence was secondary to TURP in three patients and was secondary to posterior urethroplasty performed following traumatic pelvic fracture in seven patients. Pedicled rectus abdominalis muscle and fascial flaps, approximately 2.5 cm wide and 15 cm long, were isolated. The flaps were inserted into a perineal incision through a subcutaneous tunnel. The free end of the flap was sectioned to form two muscle strips, each 3 cm in length, and inserted into the space between bulbar urethra and corpus cavernosa. After adequate sling tension had been achieved, the two strips of muscle were anastomosed around the bulbar urethra using a 2-zero polyglactin suture. The patients were followed up for between 12 and 82 months (mean 42.8 months). Complete continence was achieved with good voiding in seven of the 10 patients. In other three patients achieved good voiding following catheter removal, but incontinence was only moderately improved. A pedicled rectus muscle fascial sling of the bulbar urethra is an effective and safe treatment for male patients with mild to moderate acquired urinary incontinence, but it may not be suitable for severe incontinence or for patients with weak rectus abdominalis muscles.
Azimifar, Farhad; Hassani, Kamran; Saveh, Amir Hossein; Ghomsheh, Farhad Tabatabai
2017-11-14
Several methods including free-hand technique, fluoroscopic guidance, image-guided navigation, computer-assisted surgery system, robotic platform and patient's specific templates are being used for pedicle screw placement. These methods have screw misplacements and are not always easy to be applied. Furthermore, it is necessary to expose completely a large portions of the spine in order to access fit entirely around the vertebrae. In this study, a multi-level patient's specific template with medium invasiveness was proposed for pedicle screw placement in the scoliosis surgery. It helps to solve the problems related to the soft tissues removal. After a computer tomography (CT) scan of the spine, the templates were designed based on surgical considerations. Each template was manufactured using three-dimensional printing technology under a semi-flexible post processing. The templates were placed on vertebras at four points-at the base of the superior-inferior articular processes on both left-right sides. This helps to obtain less invasive and more accurate procedure as well as true-stable and easy placement in a unique position. The accuracy of screw positions was confirmed by CT scan after screw placement. The result showed the correct alignment in pedicle screw placement. In addition, the template has been initially tested on a metal wire series Moulage (height 70 cm and material is PVC). The results demonstrated that it could be possible to implement it on a real patient. The proposed template significantly reduced screw misplacements, increased stability, and decreased the sliding & the intervention invasiveness.
Lessons from 28 cases of reconstruction by lenticular island pedicle flap at a single institution.
Hata, H; Aoyagi, S; Homma, E; Shimizu, H
2015-05-01
Lenticular island pedicle flap (LIPF) has been reported to be one of the most useful techniques for reconstructing middle cheek skin defects. LIPF may have been used all over the world on a daily basis; however, no reports have examined a large number of LIPF cases at a single institution. A total of 28 cases of reconstruction by LIPF at the Hokkaido University Hospital from 2005 to 2013 were analysed. We examined the tumour type, location, area of defect and presence/absence of antithrombotic treatment and complications, including transient circulatory impairment, damage to facial nerves and eyelid ectropion. We found that nine patients had transiently impaired circulation. This complication was statistically more frequent in the patients without antithrombotic treatment than in the patients with antithrombotic treatment (0/8 vs. 10/20, P = 0.0292; Fisher's exact test). We revelled that LIPF have been safely performed even under antithrombotic treatment, so, when patients are taking antithrombotic agents, we should choose LIPF rather than conventional flap including cheek flap, island pedicle flap and so on. © 2014 European Academy of Dermatology and Venereology.
Unal, Cigdem; Eren, Guler Gamze; Isil, Eda; Alponat, Ahmet; Sarlak, Ahmet
2012-01-01
Reconstruction of the lumbosacral region after surgical excision of irradiated and recurrent spinal giant cell tumours remains a challenging problem. In this case report, we describe the use of the pedicled omentum flap in reconstruction of an irradiated and infected wide sacral defect of a 19-year-old male patient. The patient had radiotherapy and subsequent wide surgical resection after recurrence of the tumour. A myocutaneous flap from the gluteal area had failed previously. Local flap options could not be used because of the recent radiotherapy to the gluteal area. Since the patient had a laparotomy for tumour resection and a colostomy, abdominal muscles were not considered reliable for reconstructive procedures. A pedicled omentum flap was chosen as a reconstructive option because of its rich blood supply, large surface area, and angiogenic capacity. This report aims to describe the use of the pedicled omentum flap for reconstruction of the lumbosacral area following surgical resection of a spinal tumour, when gluteal and abdominal flap options for reconstruction are jeopardised. PMID:22754172
Unal, Cigdem; Eren, Guler Gamze; Isil, Eda; Alponat, Ahmet; Sarlak, Ahmet
2012-01-01
Reconstruction of the lumbosacral region after surgical excision of irradiated and recurrent spinal giant cell tumours remains a challenging problem. In this case report, we describe the use of the pedicled omentum flap in reconstruction of an irradiated and infected wide sacral defect of a 19-year-old male patient. The patient had radiotherapy and subsequent wide surgical resection after recurrence of the tumour. A myocutaneous flap from the gluteal area had failed previously. Local flap options could not be used because of the recent radiotherapy to the gluteal area. Since the patient had a laparotomy for tumour resection and a colostomy, abdominal muscles were not considered reliable for reconstructive procedures. A pedicled omentum flap was chosen as a reconstructive option because of its rich blood supply, large surface area, and angiogenic capacity. This report aims to describe the use of the pedicled omentum flap for reconstruction of the lumbosacral area following surgical resection of a spinal tumour, when gluteal and abdominal flap options for reconstruction are jeopardised.
Varghese, Vicky; Saravana Kumar, Gurunathan; Krishnan, Venkatesh
2017-02-01
Pedicle screws are widely used for the treatment of spinal instability by spine fusion. Screw loosening is a major problem of spine fusion, contributing to delayed patient recovery. The present study aimed to understand the factor and interaction effects of density, insertion depth and insertion angle on pedicle screw pull out strength and insertion torque. A pull out study was carried out on rigid polyurethane foam blocks representing osteoporotic to normal bone densities according to the ASTM-1839 standard. It was found that density contributes most to pullout strength and insertion torque. The interaction effect is significant (p < 0.05) and contributes 8% to pull out strength. Axial pullout strength was 34% lower than angled pull out strength in the osteoporotic bone model. Insertion angle had no significant effect (p > 0.05) on insertion torque. Pullout strength and insertion torque had no significant correlation (p > 0.05) in the case of the extremely osteoporotic bone model. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.
Liu, B; Hao, X; Goan, M
2000-05-01
To investigate the blood supply patterns and the clinical liability of a leg flap pedicle-included with cutaneous nerve and its concomitant vessels. Fresh cadaver legs with thirty-two in infants and two in adults were anatomically examined after the intravenous injection of the red Chlorinated Poly Vingl Choride (CPVC). Five patients with the soft tissue defects were selected for the treatment with the flap pedicle-included with the cutaneous nerve and its concomitant vessels. Four main cutaneous nerves were found in the leg after they perforated the deep fascia out. They were companioned with their concomitant vessels with different blood-supply pateeerns, which the upper part of the leg was in an axial pattern and the lower part was in a "chain-type anastomosing" pattern. Following the above-mentioned findings, five cases were successfully treated with this led flap. The leg flap should be designed along the cutaneous nerve and its concomitant vessels. When the flap is applied in the area of blood supply with "chain-type anastomosing" pattern, the deep fascia should also be included in the flap.
[Modified pectoralis major myocutaneous flap in reconstruction of head and neck defects].
Chen, Jie; Huang, Wenxiao; Li, Zan; Zhou, Xiao; Yu, Jianjun; Bao, Ronghua; Zhang, Hailin; Ling, Hang
2015-05-01
To report the experience of use of modified pectoralis major myocutaneous (PMMC) flaps in reconstruction of head and neck postoperative defects. A total of 107 patients who underwent head and neck defect reconstruction using modified PMMC flaps after tumor rescetion between Jan 2008 and Dec 2013 were analyzed retrospectively. The success rate of reconstruction with modified PMMC flaps was 94.4% (101/107). Five patients had partial flap necrosis and their wounds healed with dressing change. One patient (0.9%) had total flap necrosis, followed by the second reconstruction using contralateral PMMC flap. The modified falcate PMMC flap can obtain optimum quantity of the skin in the chest and decreasing the closing tension of the donnor site in favor of wound healing. The pedicle without muscle will not only maintain the partial function of the pectoralis major, but also help to avoid pressing the vascular pedicle within the subclavian tunnel. The muscular element the pedicled muscles of the PMMC flap can increase the ability of the flap to resist infection, which can use for covering an exposed carotid artery and improving the neck fibrosis of irradiated patients.
Post-traumatic arteriovenous fistula of the hepatic pedicle.
Ibn Majdoub Hassani, K; Mohsine, R; Belkouchi, A; Bensaid, Y
2010-10-01
Hepatico-portal fistula (HPF) is a rare condition, most often of post-traumatic or iatrogenic origin and occasionally secondary to a ruptured aneurysm of the hepatic artery into the portal vein. HPF in extrahepatic locations often results in portal hypertension (PHT). While Doppler ultrasound, CT angiography, and magnetic resonance angiography are usually demonstrative, arteriography remains indispensable to clarify the exact anatomical configuration. In the treatment of these arteriovenous (AV) fistulas, open surgical approaches have increasingly given way to radiological embolization techniques, especially in intrahepatic locations, but surgery remains indicated for AV fistulas of the hepatic pedicle where maintenance of hepatic arterial flow is a priority of treatment. We report a patient who had an AV fistula of the hepatic pedicle with resultant PHT presenting 5 years after open abdominal trauma. Treatment was surgical; the immediate and long-term postoperative course was uneventful with regression of PHT. Through analysis of this case and a review of the literature, we discuss the clinical, paraclinical, therapeutic, and prognostic features of this lesion. Copyright © 2010. Published by Elsevier Masson SAS.
Andi, Shi; Lin, Zeng; Jing, Liu
2017-06-01
This study aims to determine the influence of unilateral chewing on metabolic characteristics of masseter muscle fibers in rats and the regulatory effect of an adenosine monophosphate activated protein kinase (AMPK) signal pathway on metabolism. Rats were submitted to exodontia of all the right maxillary molars and divided into 2, 4, 6, and 8 weeks groups, and corresponding control groups were set as well. Sections were stained by nicotine adenine dinucleotide tetrazolim reductase(NADH-TRase) to demonstrate the types, proportion, and density of masseter muscle fibers. AMPKα1 and p-AMPK(Thr172) levels in bilateral masseter muscles were detected by Western blot. In the 2-week group, the percentage of dark fibers augmented in the ipsilateral side, whereas the percentage of intermediary fibers in the contralateral side was increased accompanied by a decrease of light fibers, compared with the control group (P<0.05). The percentage of dark fibers was increased in the bilateral sides, whereas the percentage of dark fiber in the ipsilateral sides surpassed that of the contralateral sides in the 4, 6, and 8-week groups. The percentage of intermediary fibers was decreased in the bilateral sides in the 6 and 8-week groups (P<0.05). The percentage of light fibers was reduced in the ipsilateral sides in the 8-week group, whereas no alteration was observed in contralateral sides (P>0.05). In the ipsilateral sides, p-AMPK (Thr172)/AMPKα1 levels were increased in the 2 and 4-week groups (P<0.05), whereas no change was observed in the contralateral sides in either group (P>0.05). Unilateral chewing increases the oxidative metabolic ability in bilateral masseter muscle fibers especially in the non-working side accompanied with change of muscle fiber types. The improvement of aerobic metabolism ability is related to the AMPK signal pathway. .
Koller, Heiko; Schmidt, Rene; Mayer, Michael; Hitzl, Wolfgang; Zenner, Juliane; Midderhoff, Stefan; Middendorf, Stefan; Graf, Nicolaus; Gräf, Nicolaus; Resch, H; Wilke, Hans-Joachim; Willke, Hans-Joachim
2010-12-01
Clinical studies reported frequent failure with anterior instrumented multilevel cervical corpectomies. Hence, posterior augmentation was recommended but necessitates a second approach. Thus, an author group evaluated the feasibility, pull-out characteristics, and accuracy of anterior transpedicular screw (ATPS) fixation. Although first success with clinical application of ATPS has already been reported, no data exist on biomechanical characteristics of an ATPS-plate system enabling transpedicular end-level fixation in advanced instabilities. Therefore, we evaluated biomechanical qualities of an ATPS prototype C4-C7 for reduction of range of motion (ROM) and primary stability in a non-destructive setup among five constructs: anterior plate, posterior all-lateral mass screw construct, posterior construct with lateral mass screws C5 + C6 and end-level fixation using pedicle screws unilaterally or bilaterally, and a 360° construct. 12 human spines C3-T1 were divided into two groups. Four constructs were tested in group 1 and three in group 2; the ATPS prototypes were tested in both groups. Specimens were subjected to flexibility test in a spine motion tester at intact state and after 2-level corpectomy C5-C6 with subsequent reconstruction using a distractable cage and one of the osteosynthesis mentioned above. ROM in flexion-extension, axial rotation, and lateral bending was reported as normalized values. All instrumentations but the anterior plate showed significant reduction of ROM for all directions compared to the intact state. The 360° construct outperformed all others in terms of reducing ROM. While there were no significant differences between the 360° and posterior constructs in flexion-extension and lateral bending, the 360° constructs were significantly more stable in axial rotation. Concerning primary stability of ATPS prototypes, there were no significant differences compared to posterior-only constructs in flexion-extension and axial rotation. The 360° construct showed significant differences to the ATPS prototypes in flexion-extension, while no significant differences existed in axial rotation. But in lateral bending, the ATPS prototype and the anterior plate performed significantly worse than the posterior constructs. ATPS was shown to confer increased primary stability compared to the anterior plate in flexion-extension and axial rotation with the latter yielding significance. We showed that primary stability after 2-level corpectomy reconstruction using ATPS prototypes compared favorably to posterior systems and superior to anterior plates. From the biomechanical point, the 360° instrumentation was shown the most efficient for reconstruction of 2-level corpectomies. Further studies will elucidate whether fatigue testing will enhance the benefit of transpedicular anchorage with posterior constructs and ATPS.
Ureteric entrapment in sacroiliac joint causing hydroureter and ipsilateral kidney hypertrophy.
Otsuru, Yurie; Kondo, Chuichi; Hara, Shohei; Takahashi, Hideo; Matsuno, Kenjiro
2018-06-01
A unilateral megaureter was found in an elderly female cadaver during routine dissection. The left proximal ureter, which was thick and convolute, descended and entered into the pelvic cavity, where the distal ureter was attached to the posterior pelvic wall at the inlet level. Removal of connective tissue surrounding the attached region revealed ureteric entrapment in the sacroiliac joint. The ipsilateral kidney, from which the megaureter originated, showed no pelvicalyceal dilatation. In contrast, the left kidney was enlarged, weighing 24% more than the right kidney. Differences in the upper urinary system between the obstructed and normal sides were examined in terms of gross anatomy, measurements, and histology. Although ureteric obstruction frequently causes hydroureter and hydronephrosis, the present case is very rare as the incomplete obstruction may have stimulated ipsilateral kidney growth, instead of contralateral compensatory augmentation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lisbona, R.; Rennie, W.R.J.; Daniel, R.K.
1980-02-01
Free vascularized bone grafting is a new technique applied to the reconstructive surgery of long bones affected by aggressive benign or malignant processes, as well as traumatic deficiencies. These bone lesions may be treated by en bloc excision and replacement with fibular segments or osteocutaneous flaps from the groin isolated on their vascular pedicle. Microvascular anastomosis of the pedicle at the recipient site is necessary. Radionuclide bone imaging is unique in the assessment of the free vascularized bone graft because postoperative graft uptake of radiopharmaceutical reflects patent anastomoses and segmental bone viability.
Takaso, Masashi; Nakazawa, Toshiyuki; Imura, Takayuki; Fukuda, Michinari; Takahashi, Kazuhisa; Ohtori, Seiji
2018-03-01
A retrospective cohort study was performed. The purpose of this study was to determine the efficacy and safety of stopping segmental pedicle screw instrumentation constructs at L5 in the treatment of neuromuscular scoliosis. Duchenne muscular dystrophy and spinal muscular atrophy are flaccid neuromuscular disorders in which gradual deterioration is the hallmark and have a lot of characteristics in common despite differences in etiology. Instrumentation and fusion to the sacrum/pelvis has been a mainstay in the surgical treatment of flaccid neuromuscular scoliosis and recommended to correct pelvic obliquity. However, the caudal extent of instrumentation and fusion in the surgical treatment of flaccid neuromuscular scoliosis has remained a matter of considerable debate and there have been few studies on the use of segmental pedicle screw instrumentation for flaccid neuromuscular scoliosis. From 2005 to 2007, a total of 27 consecutive patients with neuromuscular disorders (20 Duchenne muscular dystrophy and 7 spinal muscular atrophy), aged 11 to 17 years, underwent segmental pedicle screw instrumentation and fusion only to L5. Assessment was performed clinically and with radiologic measurements. Minimum 2-year follow-up was required for inclusion in this study. Twenty patients were enrolled in this study. No patient was lost to follow-up. All patients had L5 tilt of less than 15° and a coronal curve with apex L2 or higher preoperatively. Preoperative coronal curve averaged 70° (range: 51°-88°), with a postoperative mean of 15° (range: 5°-25°) and 17° (range: 6°-27°) at the last follow-up. The pelvic obliquity improved from 15° (range: 9°-25°) preoperatively to 5° (range: 3°-8°) postoperatively and 6° (range: 3°-8°) at the last follow-up. The L5 tilt improved from 9° (range: 2°-14°) preoperatively to 2° (range: 0°-4°) postoperatively and 2° (range: 0°-5°) at the last follow-up. Physiologic sagittal plane alignment was recreated after surgery and maintained long-term. There was no significant loss of correction of coronal curve and pelvic obliquity. There was no major complication. Segmental pedicle screw instrumentation and fusion to L5 was safe and effective in patients with flaccid neuromuscular scoliosis with apex L2 or higher and minimal L5 tilt of less than 15°. Segmental pedicle screw instrumentation ending at L5 offered the ability to correct spinal deformity and pelvic obliquity initially, intermediate and even long-term, with no major complications. This method in appropriate patients can be a viable alternative to instrumentation and fusion to the sacrum/pelvis in the surgical treatment of flaccid neuromuscular scoliosis. N/A.
da Cruz, José Arnaldo Shiomi; Dos Reis, Sabrina Thalita; Cunha Frati, Rodrigo Marcus; Duarte, Ricardo Jordão; Nguyen, Hiep; Srougi, Miguel; Passerotti, Carlo Camargo
Virtual reality surgical simulators (VRSS) have been showing themselves as a valuable tool in laparoscopy training and education. Taking in consideration the effectiveness of the VRSS, new uses for this tool have been purposed. In sports, warming up before exercise clearly shows benefit in performance. It is hypothesized that warming up in the VRSS before going to the operating room may show benefit in surgical performance. Verify whether there is benefit in surgical performance with preoperatory warm-up using a VRSS. A total of 20 medical students with basic knowledge in laparoscopy were divided in 2 groups (I and II). Group I performed a laparoscopic cholecystectomy in a porcine model. Group II performed preoperative warm-up in a VRSS and then performed a laparoscopic cholecystectomy in a porcine model. The performance between both groups was compared regarding quantitative parameters (time for dissection of the gallbladder pedicle, time for clipping the pedicle, time for cutting the pedicle, time for gallbladder removal, total operative time, and aspirated blood loss) and qualitative parameters (depth perception, bimanual dexterity, efficiency, tissue handling, and autonomy) based on a previously validated score system, in which the higher the score, the better the result. Data were analyzed with level of significance of 5%. The group that underwent preoperative warm-up (group II) showed significantly superior results as to the time for dissection of the gallbladder pedicle (11.91 ± 9.85 vs. 4.52 ± 2.89min, p = 0.012), time for clipping the pedicle (5.51 ± 2.36 vs. 2.89 ± 2.76min, p = 0.004), time for cutting the pedicle (1.84 ± 0.7 vs. 1.13 ± 0.51, p = 0.019), aspirated blood loss (171 ± 112 vs. 57 ± 27.8ml, p = 0.006), depth perception (4.5 ± 0.7 vs. 3.3 ± 0.67, p = 0.004), bianual dexterity (4.2 ± 0.78 vs. 3.3 ± 0.67, p = 0.004), tissue handling (4.2 ± 0.91 vs. 3.6 ± 0.66, p = 0.012), and autonomy (4.9 ± 0.31 vs. 3.6 ± 0.96, p = 0.028). There was no difference in time for gallbladder removal (11.58 ± 4.31 vs. 15.08 ± 4.51min, p = 0.096), total operative time (30.8 ± 11.07 vs. 25.60 ± 5.10min, p = 0.188), and efficiency (4 ± 0.66 vs. 3.6 ± 0.69, p = 0.320). The practice of preoperative warm-up training seems to benefit surgical performance even in subject with mild laparoscopic experience. Copyright © 2016 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Yu, Kaifu; Xu, Yongqing; Tan, Hongbo; He, Xiaoqing; Cai, Dixin; Zhou, Tianhua; Luo, Haotian; Duan, Jiazhang
2016-03-01
To investigate the feasibility and early effectiveness to treat osteonecrosis of the femoral head (ONFH) with pedicled iliac bone graft assisted by individual digital design and three dimensional (3D) printed navigation templates. Between February and June 2014, 15 patients (24 hips) with ONFH underwent pedicled iliac bone graft assisted by individual digital design and 3D printed navigation templates. There were 11 males (17 hips) and 4 females (7 hips) with a mean age of 38 years (range, 18-56 years) and a mean disease duration of 7.5 months (range, 1-24 months); the left hip was involved in 2 cases, the right hip in 4 cases, and both hips in 9 cases. There were 7 cases (12 hips) of steroid-induced ONFH, 5 cases (8 hips) of alcohol-induced ONFH, 1 case (1 hip) of traumatic ONFH, and 2 cases (3 hips) of idiopathic ONFH. The preoperative Harris score was 56.60 ± 6.97. According to Association Research Circulation Osseous (ARCO) staging system, 5 hips were classified as stage IIB, 8 hips as stage IIC, 6 hips as stage IIIB, and 5 hips as stage IIIC. The navigation templates were designed and printed to assist accurate location and debridement of necrosis area according to preoperative CT scanning at the beginning of pedicled iliac bone grafting procedure. The mean operation time was 135 minutes (range, 120-160 minutes), mean amount of bleeding was 255 mL (range, 200-300 mL). All the wounds healed primarily, no complication of deep vein thrombosis or infection was observed. All patients were followed up 12-16 months (mean, 14 months). The location of necrosis area was in accordance with preoperative design, which was removed completely without penetration of joint surface, pedicled iliac bone graft was performed at the right site according to postoperative imaging examination. Radiographically, graft fusion was achieved at 2.7 months (range, 2-3 months) in all patients. All the hips had no collapse during follow-up. Hip pain was relieved, and range of motion was improved. The Harris score was significantly improved to 89.53 ± 5.83 at last follow-up (t = 14.3 19, P = 0.000). The results were excellent in 12 hips, good in 10 hips, and fair in 2 hips according to Harris score standard. Pedicled iliac bone graft assisted by individual digital design and 3D printed navigation templates for treatment of adult ONFH has the advantages of accurate location and complete debridement of necrosis area, so satisfactory results can be obtained.
Qatawneh, Ayman; Thekrallah, Fida; Bata, Majed; Al-Kazaleh, Fawaz; Almustafa, Mahmoud; Abu-Kader, Ilham
2013-06-01
Trans-vaginal sacrospinous colpopexy is one of the surgical procedures used to repair varying degrees of vaginal vault and uterovaginal prolapse. The purpose of this study is to analyse the potential risk factors of surgical failure following sacrospinous colpopexy. A retrospective study of 114 women who underwent unilateral sacrospinous colpopexy at Jordan University Hospital from January 2005 to January 2008 were included. Patient demographics, clinical characteristics and concomitant pelvic organ prolapse surgery were assessed. The patients were evaluated at 6 weeks, and every 6 months thereafter. Twelve (11 %) had recurrent apical (vaginal cuff) prolapse, 26 (23 %) had recurrent prolapse at any compartment were compared with those who had successful surgery. Univariate and logistic regression analyses were used to assess the independent prognostic values of the variables associated with surgical failure. After a mean follow-up of 40 months, the statistically significant predictors of surgical failure included the presence of advanced pre-operative stages of prolapse (stages III and IV), the more distally located points Ba, Bp and C and a lack of mesh augmentation of the anterior vaginal wall during surgery (P = 0.01, 0.027, 0.024, 0.034 and 0.006, respectively). However, a history of prior vaginal repair, the more distally located point Ba and a lack of anterior vaginal wall mesh augmentation were defined as independent predictive variables based on logistic regression analyses (P = 0.04, 0.005 and 0.046, respectively). The presence of advanced anterior vaginal wall prolapse, prior vaginal repair and a lack of mesh augmentation of the anterior compartment are significant risk factors for the surgical failure of sacrospinous suspension surgery.
Double breast contour in primary aesthetic breast augmentation: incidence, prevention and treatment.
Médard de Chardon, Victor; Balaguer, Thierry; Chignon-Sicard, Bérengère; Lebreton, Elisabeth
2010-04-01
The goal of this study was to define the incidence of double breast contour in primary aesthetic breast augmentation and to analyze its risk factors. An independent plastic surgeon analyzed the data of 200 patients who had a primary aesthetic breast augmentation with silicone gel implant and with a minimum 12-month follow-up. All patients had pre and postoperative standardized photography. Mastopexy-augmentations, breast reconstructions, breast malformations (tuberous breasts and Poland syndrome), and patients with incomplete data were excluded from the study. Assessment was achieved using an original standardized evaluation form (preoperative breast morphology, surgical options, postoperative aesthetic results). Patients were also asked to complete an exhaustive satisfaction form. A double breast contour was assessed clinically using Massiha's classification. The mean follow-up was 36 months. The double breast contour incidence was 7%. All of them were type I (the so called waterfall deformity). There was no type II (double inframammary crease). They were minor for 6.5% and major for 0.5%. They were related to a preoperative breast ptosis, subpectoral placement, and implant upper malposition. The rate of the type I was 10.5% of submuscular augmentation and 15% of preoperative breast ptosis. A double breast contour was primitive for 6% and secondary for 1% (pregnancy and breast-feeding postaugmentation). It was bilateral for 4.5% (3 cases of upper malposition, 1 case of medial malposition, 2 cases of pregnancy with breast-feeding postaugmentation and 1 patient refused a mastopexy-augmentation). It was unilateral for 2.5% related to a preoperative breast asymmetry with ptosis asymmetry and skin quality asymmetry. The satisfaction rate in the group "double contour" (14 patients) was 85.7% (vs. 91.9%). One patient had revision surgery (upper malposition). These types of deformities are fundamentally different with consideration on their clinical aspects, physiopathogeny, prevention and treatment. Type I major risk factor is subpectoral augmentation of ptotic breasts (with medium to bad skin quality and loses muscle to gland attachments). The muscle at the inferior pole of the breast is a "brake" preventing implant to fill the envelope. This risk is increased with implant malposition, constitutional ptosis asymmetry with symmetrical implant placement and selection of an insufficient implant projection or dimensions. This deformity can be avoided with selection of a subglandular or dual plane (type II or III) placement, a sufficient implant volume or projection and anatomic prosthesis. Type II is related to a lowering of a well-defined submammary fold more commonly in constricted and dens glandular breasts. This deformity can be avoided with respecting the inframammary fold, radial incisions on the gland's posterior surface, and selection of anatomic implants.
Liang, Weiqiang; Ji, Chenyang; Chen, Yuhong; Zhang, Ganling; Zhang, Jiaqi; Yao, Yuanyuan; Zhang, Jinming
2016-08-01
To evaluate the effects, particularly the incidence of anastomotic fistula, of a pedicled dartos flap around the urethral orifice in the treatment of urethroplasty of mid-shaft hypospadias. A total of 46 cases of congenital mid-shaft hypospadias were included in this study. The patients ranged in age from 0.7 to 25.4 years and the average was 5.8 years. The patients received penis chordee correction. A transverse preputial island flap was developed for urethral reconstruction. The proximal dartos of the urethral orifice was used to develop a pedicled dartos flap, which was transposed to cover and strengthen neourethral anastomosis. The ventral penile skin defect was repaired by another flap. The 46 patients were examined during follow-up visits for 6 months to 3 years. An anastomotic fistula was observed in one case (2.2 %). Scar healing without fistula was observed in another patient due to poor blood supply to part of the ventral penile skin. No other incidences of fistula, urethral rupture, flap necrosis, wound infections, urinary tract (meatal) stenosis, or urethral diverticulum were observed in the patients. A pedicled dartos flap around the urethral orifice can take advantage of well-vascularized local tissue to add a protective layer to the proximal aspect of the neourethral anastomosis for reducing the incidence of anastomotic fistula in mid-shaft hypospadias repair using a transverse preputial island flap. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Chi, Zhenglin; Chen, Yiheng; Chu, Tinggang; Gao, Weiyang; Li, Zhijie; Yan, Hede; Song, Yonghuan
2018-02-01
The conventional procedure of the sural neuro-fasciocutaneous flap enables the supply of blood and venous drainage by increasing the width of the adipofascial tissue and preserving tiny venous return routes. Moreover, skin graft is a common method for donor site closure, which may lead to some complications and influence the aesthetic appearance. We report modifications for a distally based sural neuro-fasciocutaneous perforator flap and a relaying flap for donor site closure without skin graft. Twelve patients undergoing the modified flap for foot and ankle reconstruction were included in this study between 2014 and 2016. A peroneal-based perforator, a superficial vein, and the vascular axis of the sural nerve were included in the pedicle. A Z-shape skin incision was performed to explore the perforator vessels and a relaying island perforator flap was used to close the donor site. All flaps survived completely without necrosis. The area of the flaps ranged from 16 × 8 cm to 30 × 15 cm. The diameter width of the pedicle ranged from 1.0 to 2.0 cm. A relaying perforator island flap was used in 10 cases for donor site closure and no skin graft was performed. There were no serious donor site complications. All patients were satisfied with the aesthetic outcome postoperatively at the final follow-up. The distally based sural neuro-fasciocutaneous perforator flap is considered a reliable method for foot and ankle reconstruction. The modification for flap pedicle and donor site closure method without skin graft should be recommended. Copyright © 2017. Published by Elsevier Ltd.
Li, Xiucun; Cui, Jianli; Maharjan, Suraj; Lu, Laijin; Gong, Xu
2016-01-01
Objective The purpose of this study is to determine the correlation between non-technical risk factors and the perioperative flap survival rate and to evaluate the choice of skin flap for the reconstruction of foot and ankle. Methods This was a clinical retrospective study. Nine variables were identified. The Kaplan-Meier method coupled with a log-rank test and a Cox regression model was used to predict the risk factors that influence the perioperative flap survival rate. The relationship between postoperative wound infection and risk factors was also analyzed using a logistic regression model. Results The overall flap survival rate was 85.42%. The necrosis rates of free flaps and pedicled flaps were 5.26% and 20.69%, respectively. According to the Cox regression model, flap type (hazard ratio [HR] = 2.592; 95% confidence interval [CI] (1.606, 4.184); P < 0.001) and postoperative wound infection (HR = 0.266; 95% CI (0.134, 0.529); P < 0.001) were found to be statistically significant risk factors associated with flap necrosis. Based on the logistic regression model, preoperative wound bed inflammation (odds ratio [OR] = 11.371,95% CI (3.117, 41.478), P < 0.001) was a statistically significant risk factor for postoperative wound infection. Conclusion Flap type and postoperative wound infection were both independent risk factors influencing the flap survival rate in the foot and ankle. However, postoperative wound infection was a risk factor for the pedicled flap but not for the free flap. Microvascular anastomosis is a major cause of free flap necrosis. To reconstruct complex or wide soft tissue defects of the foot or ankle, free flaps are safer and more reliable than pedicled flaps and should thus be the primary choice. PMID:27930679
Matic, Damir B; Yoo, John
2012-08-01
The pedicled masseter muscle transfer (PMMT) is introduced as a new reconstructive option for dynamic smile restoration in patients with facial paralysis. The masseter muscle is detached from both its origin and insertion and transferred to a new position to imitate the function of the native zygomaticus major muscle. Part one of this study consisted of cadaveric dissections of 4 heads (eight sides) in order to determine whether the masseter muscle could be (a) pedicled solely by its dominant neurovascular bundle and (b) repositioned directly over the native zygomaticus major. The second part of the study consisted of clinical assessments in three patients in order to confirm the applicability of this muscle transfer. Commissure excursion and vector of contraction following PMMT were compared to the non-paralyzed side. In all eight sides, the masseter muscles were successfully isolated on their pedicle and transposed on top of and in-line with the ipsilateral zygomaticus major. The mean length of the masseter and its angle from Frankfurt's horizontal line after transposition compared favorably to the native zygomaticus major muscle. In the clinical cases, the mean commissure movements of the paralyzed and normal sides were 7 mm and 12 mm respectively. The mean angles of commissural movement for the paralyzed and normal sides were 62° and 59° respectively. The PMMT can be used as a dynamic reconstruction for patients with permanent facial paralysis. As we gain experience with the PMMT, it may be possible to use it as a first-line option for patients not eligible for free micro-neurovascular reconstruction. Copyright © 2012 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Manrique, Oscar J; Bishop, Sarah N; Ciudad, Pedro; Adabi, Kian; Martinez-Jorge, Jorys; Moran, Steven L; Huang, Tony; Vijayasekaran, Aparna; Chen, Shih-Heng; Chen, Hung-Chi
2018-05-16
Lower extremity salvage following significant soft tissue loss can be complicated by lack of recipient vessel for free tissue transfer. We describe our experience in lower limb salvage for patients with no recipient vessels with the use of pedicle, free and cable bridge flaps. A retrospective review from 1985 to 2017 of patients undergoing lower limb salvage using a contralateral pedicle cross leg (PCL) flaps, free cross leg (FCL) flaps, or free cable bridge (FCB) flaps was conducted. Demographics, etiology of the reconstruction, type of flap used, donor-site vessels, defect size, operating time, time of pedicle division, length of hospital stay, time to ambulation, and complications were analyzed. A total of 53 patients (48 males and 5 females) with an average age of 35 years (range, 29-38 years) were identified. The etiology for the reconstruction was trauma in 52 patients and oncological resection in 1 patient. There were 18 PCL, 25 FCL, and 10 FCB completed. The recipient vessels for all flaps were the posterior tibial artery and vein. The average operating room times for PCL, FCL, and FCB flaps were 4, 9, and 10 hours, respectively. The average length of hospital stay was 5 weeks and average time to ambulation was 4 weeks. The average follow-up time was 7.5 years (range, 3-12 years). Complications encountered were hematoma (six), prolonged pain (six), total flap loss (two), reoperation (five), and infection (four). Limb salvage rates were 96.2%. When ipsilateral limb vessels are not available, and other reconstructive options have been exhausted, cross leg flaps can be a viable option for limb salvage in the setting of extensive defects. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Cannistra, Claudio; Piedimonte, Andrea; Albonico, Fiorella
2009-11-01
Gynecomastia is a morphostructural impairment of the mammary region in men caused by parenchymal hypertrophy or a cutaneous distortion of breast skin covering or both. The clinical classification introduced by Simon et al. in 1973 ranks gynecomastia in three degrees. Each subtype can be treated with a specific technique. This article describes an alternative surgical procedure for treating gynecomastia with severe ptosis(type III and type IIIb of Simon's classification). Fifty-eight patients were treated for gynecomastia in our Plastic Surgery Unit from 1996 to 2004. The cutaneous excess of periareolar skin is evaluated by a pinching test. A circular periareolar mark is traced corresponding to the cutaneous excess that has to be removed.Initially, liposuction of adipous tissue on the periphery of the mammary region is performed through two cutaneous 3-mm incisions at the 3 o'clock and 9 o'clock positions around the areola. After this, the liposuction incisions are enlarged from 10 o'clock to 8 o'clock and from 2 o'clockto 4 o'clock to create access for the mastectomy. This dissection creates a double dermal areolar pedicle. The new areolar position is fixed with a Benelli round block suture. A resolution of the morphologic deformity without evident scars after hair growth and a correction of the breast deformity has been observed in the 6-month follow-ups conducted for all the patients. We observed that the vascular-nervous net under the areola at 12 o'clock and 6 o'clock is very important, more so than the lateral pedicle, and the conservation of a double vascular-nervous pedicle reduces significantly the risk of areolar necrosis, especially in cases of gynecomastia type III and in cases where there is a high degree of breast malformation such as the tuberous breast.
Biomechanics of Thoracolumbar Burst and Chance-Type Fractures during Fall from Height
Ivancic, Paul C.
2014-01-01
Study Design In vitro biomechanical study. Objective To investigate the biomechanics of thoracolumbar burst and Chance-type fractures during fall from height. Methods Our model consisted of a three-vertebra human thoracolumbar specimen (n = 4) stabilized with muscle force replication and mounted within an impact dummy. Each specimen was subjected to a single fall from an average height of 2.1 m with average velocity at impact of 6.4 m/s. Biomechanical responses were determined using impact load data combined with high-speed movie analyses. Injuries to the middle vertebra of each spinal segment were evaluated using imaging and dissection. Results Average peak compressive forces occurred within 10 milliseconds of impact and reached 40.3 kN at the ground, 7.1 kN at the lower vertebra, and 3.6 kN at the upper vertebra. Subsequently, average peak flexion (55.0 degrees) and tensile forces (0.7 kN upper vertebra, 0.3 kN lower vertebra) occurred between 43.0 and 60.0 milliseconds. The middle vertebra of all specimens sustained pedicle and endplate fractures with comminution, bursting, and reduced height of its vertebral body. Chance-type fractures were observed consisting of a horizontal split fracture through the laminae and pedicles extending anteriorly through the vertebral body. Conclusions We hypothesize that the compression fractures of the pedicles and vertebral body together with burst fracture occurred at the time of peak spinal compression, 10 milliseconds. Subsequently, the onset of Chance-type fracture occurred at 20 milliseconds through the already fractured and weakened pedicles and vertebral body due to flexion-distraction and a forward shifting spinal axis of rotation. PMID:25083357
Use of Pedicled Trapezius Myocutaneous Flap for Posterior Skull Reconstruction.
Singh, Mansher; Rios Diaz, Arturo J; Cauley, Ryan; Smith, Timothy R; Caterson, E J
2015-09-01
Soft-tissue defects in posterior skull can be challenging for reconstruction. If related to tumor resection, these wound beds are generally irradiated and can be difficult from a recipient-vessel perspective for a free tissue transfer. Locoregional flaps might prove to be important reconstructive option in such patients. There is a very limited data on the usage of pedicled trapezius myocutaneous flaps for such defects. The authors reviewed existing study for usage of trapezius flap for posterior skull repair and used pedicled trapezius myocutaneous flaps based on the descending branch of superficial cervical artery (SCA) for reconstruction of posterior skull soft-tissue defect in an irradiated and infected wound. Two patients were operated for trapezius myocutaneous flap for posterior skull defects complicated by cerebrospinal fluid (CSF) leakage and epidural abscess. There was no recipient or donor-site complication at a mean follow-up of 12.5 months. Neither of the 2 patients had any functional deficits for the entire duration of the follow-up. Although this flap was able to help in controlling the CSF leakage in the first patient, it successfully healed the cavity generated from epidural abscess drainage in the second patient. The large angle of rotation coupled with the ability to complete the procedure without repositioning the patients makes trapezius myocutaneous flap an attractive option for posterior skull reconstruction. In our limited experience, the pedicled trapezius flaps are a reliable alternative as they are well vascularized and able to obliterate the soft-tissue defect completely. The recipient site healed completely in infected as well as irradiated wound beds. In addition, the donor site can be primarily closed with minimal donor-associated complication.
2013-01-01
Background Although posterior correction and fusion surgery using pedicle screws carries the risk of vascular injury, a massive postoperative hemothorax in a patient with adolescent idiopathic scoliosis (AIS) is quite rare. We here report a case of a 12-year-old girl with AIS who developed a massive postoperative hemothorax. Case presentation The patient had a double thoracic curve with Cobb angles of 63° at T2-7 and 54° at T7-12. Posterior correction and fusion surgery was performed using a segmental pedicle screw construct placed between T2 and T12. Although the patient's respiration was stable during the surgery, 20 minutes after removing the trachea tube, the patient’s pulse oximetry oxygen saturation suddenly decreased to 80%. A contrast CT scan showed a massive left hemothorax, and a drainage tube was quickly inserted into the chest. The patient was re-intubated and a positive end-expiratory pressure of 5 cmH2O applied, which successfully stopped the bleeding. The patient was extubated 4 days after surgery without incident. Based on contrast CT scans, it was suspected that the hemothorax was caused by damage to the intercostal arteries or branches during pedicle probing on the concave side of the upper thoracic curve. Extensive post-surgical blood tests, echograms, and CT and MRI radiographs did not detect coagulopathy, pulmonary or vascular malformation, or any other possible causative factors. Conclusion This case underscores the potential risk of massive hemothorax related to thoracic pedicle screw placement, and illustrates that for this serious complication, respiratory management with positive airway pressure, along with a chest drainage tube, can be an effective treatment option. PMID:23577922
Ogura, Yoji; Watanabe, Kota; Hosogane, Naobumi; Toyama, Yoshiaki; Matsumoto, Morio
2013-04-11
Although posterior correction and fusion surgery using pedicle screws carries the risk of vascular injury, a massive postoperative hemothorax in a patient with adolescent idiopathic scoliosis (AIS) is quite rare. We here report a case of a 12-year-old girl with AIS who developed a massive postoperative hemothorax. The patient had a double thoracic curve with Cobb angles of 63° at T2-7 and 54° at T7-12. Posterior correction and fusion surgery was performed using a segmental pedicle screw construct placed between T2 and T12. Although the patient's respiration was stable during the surgery, 20 minutes after removing the trachea tube, the patient's pulse oximetry oxygen saturation suddenly decreased to 80%. A contrast CT scan showed a massive left hemothorax, and a drainage tube was quickly inserted into the chest. The patient was re-intubated and a positive end-expiratory pressure of 5 cmH(2)O applied, which successfully stopped the bleeding. The patient was extubated 4 days after surgery without incident. Based on contrast CT scans, it was suspected that the hemothorax was caused by damage to the intercostal arteries or branches during pedicle probing on the concave side of the upper thoracic curve. Extensive post-surgical blood tests, echograms, and CT and MRI radiographs did not detect coagulopathy, pulmonary or vascular malformation, or any other possible causative factors. This case underscores the potential risk of massive hemothorax related to thoracic pedicle screw placement, and illustrates that for this serious complication, respiratory management with positive airway pressure, along with a chest drainage tube, can be an effective treatment option.
[PREPUTIAL PEDICLED FLAP PHALLOPLASTY FOR REPAIR OF SEVERE WEBBED PENIS].
Huang, Yidong; Zeng, Li; Huang, Guizhen; Kang, Lei; Huang, Lugang
2016-11-08
To evaluate the effectiveness of preputial pedicled flap phalloplasty for repair of severe webbed penis. Between May 2011 and May 2015, 23 boys with severe webbed penis were treated. The age ranged from 2 years and 8 months to 8 years and 3 months (mean, 4 years and 8 months). According to El-Koutby & El Gohary classification, 14 cases were rated as grade 3 simple webbed penis and 9 cases as compound webbed penis (2 cases of type 1, 2 cases of type 2, and 5 cases of type 3). The penis length was 2.1-5.4 cm (mean, 3.4 cm), and the penoscrotal angle was 130-160° (mean, 144°). All the glans could not be exposed. No other urinary system diseases and no history of penile surgery were found in children. All cases underwent one stage preputial pedicled flap phalloplasty. After successful correction, the penis length was 3.6-6.4 cm (mean, 4.7 cm); the penoscrotal angle was 90-110° (mean, 97°). Clear skin boundaries were observed at penile and scrotal parts. No web skin or scrotal skin was left on the penis. Primary healing of incision was obtained, with no necrosis of the flap or infection. All cases were followed up 12 to 41 months (mean, 25 months). No penile curvature, abnormal sensation of glans, or recurrence of the penoscrotal angle occurred, and the patients had normal urination. Preputial pedicled flap phalloplasty can be used as one stage repair for severe webbed penis. The penis is close to natural state and had satisfactory appearance, avoiding the possibility of long-term edema and penile curvature.
Pireau, Nathalie; Cordemans, Virginie; Banse, Xavier; Irda, Nadia; Lichtherte, Sébastien; Kaminski, Ludovic
2017-11-01
Spine surgery still remains a challenge for every spine surgeon, aware of the potential serious outcomes of misplaced instrumentation. Though many studies have highlighted that using intraoperative cone beam CT imaging and navigation systems provides higher accuracy than conventional freehand methods for placement of pedicle screws in spine surgery, few studies are concerned about how to reduce radiation exposure for patients with the use of such technology. One of the main focuses of this study is based on the ALARA principle (as low as reasonably achievable). A prospective randomized trial was conducted in the hybrid operating room between December 2015 and December 2016, including 50 patients operated on for posterior instrumented thoracic and/or lumbar spinal fusion. Patients were randomized to intraoperative 3D acquisition high-dose (standard dose) or low-dose protocol, and a total of 216 pedicle screws were analyzed in terms of screw position. Two different methods were used to measure ionizing radiation: the total skin dose (derived from the dose-area product) and the radiation dose evaluated by thermoluminescent dosimeters on the surgical field. According to Gertzbein and Heary classifications, low-dose protocol provided a significant higher accuracy of pedicle screw placement than the high-dose protocol (96.1 versus 92%, respectively). Seven screws (3.2%), all implanted with the high-dose protocol, needed to be revised intraoperatively. The use of low-dose acquisition protocols reduced patient exposure by a factor of five. This study emphasizes the paramount importance of using low-dose protocols for intraoperative cone beam CT imaging coupled with the navigation system, as it at least does not affect the accuracy of pedicle screw placement and irradiates drastically less.
Custom-built tools for the study of deer antler biology.
Chu, Wenhui; Zhao, Haiping; Li, Junde; Li, Chunyi
2017-06-01
Deer antlers can be developed into multiple novel models to study growth and development of tissues for biomedical research. To facilitate this process, we have invented and further refined five custom-built tools through three decades of antler research. These are: 1. Pedicle growth detector to pinpoint the timing when pedicle growth is initiated, thus stimuli for pedicle and first antler formation can be investigated and identified. 2. Thin periosteum slice cutter to thinly slice (0.2mm or 0.7 mm thick) a whole piece of antlerogenic periosteum (AP) or pedicle periosteum (PP), which facilitates gene delivery into cells resident in these tissues, thus making transgenic antlers possible. 3. The porous periosteum multi-needle punch to effectively loosen the dense AP or PP tissue. This allows most cells of the periosteum to come into direct contact with treating solutions, thus making artificial manipulation of antler development possible. 4. The intra-dermal pocket maker to cut the thin dermal tissue (less than 2 mm in thickness) of a male deer calf horizontally into two layers to make an intra-dermal pocket. This allows loading of AP tissue intra-dermally to test the theory of "antler stem cell niche" in vivo . 5. The sterile periosteum sampling system to allow aseptic collection of the AP, PP or the antler growth centre tissue on farm, thus allowing antler generation, regeneration or rapid growth to be investigated in vitro . Overall, we believe the application of contemporary cellular and molecular biological techniques coupled with these custom-built tools would greatly promote the establishment of this unique and novel model for the benefits of biomedical research, and hence human health.
Belcik, J. Todd; Davidson, Brian P.; Xie, Aris; Wu, Melinda D.; Yadava, Mrinal; Qi, Yue; Liang, Sherry; Chon, Chae Ryung; Ammi, Azzdine Y.; Field, Joshua; Harmann, Leanne; Chilian, William M.; Linden, Joel; Lindner, Jonathan R.
2017-01-01
Background Augmentation of tissue blood flow by therapeutic ultrasound is thought to rely on convective shear. Microbubble contrast agents that undergo ultrasound-mediated cavitation markedly amplify these effects. We hypothesized that purinergic signalling is responsible for shear-dependent increases in muscle perfusion during therapeutic cavitation. Methods Unilateral exposure of the proximal hindlimb of mice (with or without ischemia produced by iliac ligation) to therapeutic ultrasound (1.3 MHz, mechanical index 1.3) was performed for ten minutes after intravenous injection of 2×108 lipid microbubbles. Microvascular perfusion was evaluated by low-power contrast ultrasound perfusion imaging. In vivo muscle ATP release and in vitro ATP release from endothelial cells or erythrocytes were assessed by a luciferin-luciferase assay. Purinergic signalling pathways were assessed by studying interventions that either (1) accelerated ATP degradation; (2) inhibited P2Y receptors, adenosine receptors, or KATP channels; or (3) inhibited downstream signalling pathways involving endothelial nitric oxide synthase (eNOS) or prostanoid production (indomethacin). Augmentation in muscle perfusion by ultrasound cavitation was assessed in a proof-of-concept clinical trial in 12 subjects with stable sickle cell disease (SCD). Results Therapeutic ultrasound cavitation increased muscle perfusion by 7-fold in normal mice, reversed tissue ischemia for up to 24 hrs in the murine model of peripheral artery disease, and doubled muscle perfusion in patients with SCD. Augmentation in flow extended well beyond the region of ultrasound exposure. Ultrasound cavitation produced a nearly 40-fold focal and sustained increase in ATP, the source of which included both endothelial cells and erythrocytes. Inhibitory studies indicated that ATP was a critical mediator of flow augmentation that acts primarily through either P2Y receptors or through adenosine produced by ectonucleotidase activity. Combined indomethacin and inhibition of eNOS abolished the effects of therapeutic ultrasound, indicating downstream signalling through both NO and prostaglandins. Conclusions Therapeutic ultrasound using microbubble cavitation to increase muscle perfusion relies on shear-dependent increases in ATP which can act through a diverse portfolio of purinergic signalling pathways. These events can reverse hindlimb ischemia in mice for >24 hours, and increase muscle blood flow in patients with sickle cell disease. Clinical Trial Registration NCT01566890 (https://clinicaltrials.gov/ct2/show/NCT01566890) PMID:28174191
Belcik, J Todd; Davidson, Brian P; Xie, Aris; Wu, Melinda D; Yadava, Mrinal; Qi, Yue; Liang, Sherry; Chon, Chae Ryung; Ammi, Azzdine Y; Field, Joshua; Harmann, Leanne; Chilian, William M; Linden, Joel; Lindner, Jonathan R
2017-03-28
Augmentation of tissue blood flow by therapeutic ultrasound is thought to rely on convective shear. Microbubble contrast agents that undergo ultrasound-mediated cavitation markedly amplify these effects. We hypothesized that purinergic signaling is responsible for shear-dependent increases in muscle perfusion during therapeutic cavitation. Unilateral exposure of the proximal hindlimb of mice (with or without ischemia produced by iliac ligation) to therapeutic ultrasound (1.3 MHz, mechanical index 1.3) was performed for 10 minutes after intravenous injection of 2×10 8 lipid microbubbles. Microvascular perfusion was evaluated by low-power contrast ultrasound perfusion imaging. In vivo muscle ATP release and in vitro ATP release from endothelial cells or erythrocytes were assessed by a luciferin-luciferase assay. Purinergic signaling pathways were assessed by studying interventions that (1) accelerated ATP degradation; (2) inhibited P2Y receptors, adenosine receptors, or K ATP channels; or (3) inhibited downstream signaling pathways involving endothelial nitric oxide synthase or prostanoid production (indomethacin). Augmentation in muscle perfusion by ultrasound cavitation was assessed in a proof-of-concept clinical trial in 12 subjects with stable sickle cell disease. Therapeutic ultrasound cavitation increased muscle perfusion by 7-fold in normal mice, reversed tissue ischemia for up to 24 hours in the murine model of peripheral artery disease, and doubled muscle perfusion in patients with sickle cell disease. Augmentation in flow extended well beyond the region of ultrasound exposure. Ultrasound cavitation produced an ≈40-fold focal and sustained increase in ATP, the source of which included both endothelial cells and erythrocytes. Inhibitory studies indicated that ATP was a critical mediator of flow augmentation that acts primarily through either P2Y receptors or adenosine produced by ectonucleotidase activity. Combined indomethacin and inhibition of endothelial nitric oxide synthase abolished the effects of therapeutic ultrasound, indicating downstream signaling through both nitric oxide and prostaglandins. Therapeutic ultrasound using microbubble cavitation to increase muscle perfusion relies on shear-dependent increases in ATP, which can act through a diverse portfolio of purinergic signaling pathways. These events can reverse hindlimb ischemia in mice for >24 hours and increase muscle blood flow in patients with sickle cell disease. URL: http://clinicaltrials.gov. Unique identifier: NCT01566890. © 2017 American Heart Association, Inc.