Neglected Posterior Dislocation of Hip in Children - A Case Report.
Pal, Chandra Prakash; Kumar, Deepak; Sadana, Ashwani; Dinkar, Karuna Shankar
2014-01-01
Traumatic dislocation of the hip in children is a rare injury. We report the outcome of 2 patients of neglected hip dislocation which were treated by open reduction and internal fixation by k-wires. We treat 2 children both girls (one was of 4 years and other was 7 years of age). In both cases dislocation was unilateral and was not associated with any facture. Both cases were of posterior dislocation. in both cases open reduction and internal fixation was done by k wires. Hip spica was applied post operatively in both cases. The k wire was removed at 3 to 4 weeks. Patients were allowed to bear weight from gradual to full weight bearing after 6 weeks. We conclude that open reduction is a satisfactory treatment for neglected hip dislocation. It prevents not only deformity but also maintains limb length.
Reddy, A V Gurava; Eachempati, Krishna Kiran; Mugalur, Aakash; Suchinder, A; Rao, V B N Prasad; Kamurukuru, Nalanda
2017-01-01
Introduction: Periprosthetic fractures and dislocation in the early post-operative period can be disastrous both for the surgeon and the patient. However, undisplaced periprosthetic fractures presenting with dislocation is uncommon. We describe successful management of two cases (one bilateral dislocation and one unilateral dislocation) of undisplaced iatrogenic fractures in total hip arthroplasty (THA) presenting as early dislocation. Case Report: Case 1 was a 45-year-old female with osteoarthritis of hip secondary to developmental dysplasia of the hip with bilateral early nontraumatic dislocation with bilateral identical periprosthetic fracture. It was managed by revision to long stem and encirclage wiring. Case 2 presented with early dislocation in the 2nd week post THA. We found an intertrochanteric fracture intra-operatively with unstable implant. Acetabular component and femoral component revision were done with reconstruction of the greater trochanter. Discussion: These fractures could be occult iatrogenic fractures characteristic of taper wedge stems which presented as early nontraumatic dislocation in the post-operative period. The prosthesis subsidence, loss of muscle tension and change of version might be the factors leading to dislocation. Conclusion: Unrecognized incomplete intraoperative fracture can occur with tapered wedge uncemented stems which can present as a dislocation in the immediate post-operative period. This will require early revision of the femoral component. PMID:29051875
Postural asymmetries in young adults with cerebral palsy.
Rodby-Bousquet, Elisabet; Czuba, Tomasz; Hägglund, Gunnar; Westbom, Lena
2013-11-01
The purpose was to describe posture, ability to change position, and association between posture and contractures, hip dislocation, scoliosis, and pain in young adults with cerebral palsy (CP). Cross-sectional data of 102 people (63 males, 39 females; age range 19-23 y, median 21 y) out of a total population with CP was analysed in relation to Gross Motor Function Classification System (GMFCS) levels I (n=38), II (n=21), III (n=13), IV (n=10), and V (n=20). The CP subtypes were unilateral spastic (n=26), bilateral spastic (n=45), ataxic (n=12), and dyskinetic CP (n=19). The Postural Ability Scale was used to assess posture. The relationship between posture and joint range of motion, hip dislocation, scoliosis, and pain was analysed using logistic regression and Spearman's correlation. At GMFCS levels I to II, head and trunk asymmetries were most common; at GMFCS levels III to V postural asymmetries varied with position. The odds ratios (OR) for severe postural asymmetries were significantly higher for those with scoliosis (OR=33 sitting), limited hip extension (OR=39 supine), or limited knee extension (OR=37 standing). Postural asymmetries correlated to hip dislocations: supine (r(s) =0.48), sitting (r(s) =0.40), standing (r(s) =0.41), and inability to change position: supine (r(s) =0.60), sitting (r(s) =0.73), and standing (r(s) =0.64). Postural asymmetries were associated with scoliosis, hip dislocations, hip and knee contractures, and inability to change position. © 2013 The Authors. Developmental Medicine & Child Neurology published by John Wiley & Sons Ltd on behalf of Mac Keith Press.
Postural asymmetries in young adults with cerebral palsy
Rodby-Bousquet, Elisabet; Czuba, Tomasz; Hägglund, Gunnar; Westbom, Lena
2013-01-01
Aim The purpose was to describe posture, ability to change position, and association between posture and contractures, hip dislocation, scoliosis, and pain in young adults with cerebral palsy (CP). Methods Cross-sectional data of 102 people (63 males, 39 females; age range 19–23y, median 21y) out of a total population with CP was analysed in relation to Gross Motor Function Classification System (GMFCS) levels I (n=38), II (n=21), III (n=13), IV (n=10), and V (n=20). The CP subtypes were unilateral spastic (n=26), bilateral spastic (n=45), ataxic (n=12), and dyskinetic CP (n=19). The Postural Ability Scale was used to assess posture. The relationship between posture and joint range of motion, hip dislocation, scoliosis, and pain was analysed using logistic regression and Spearman’s correlation. Results At GMFCS levels I to II, head and trunk asymmetries were most common; at GMFCS levels III to V postural asymmetries varied with position. The odds ratios (OR) for severe postural asymmetries were significantly higher for those with scoliosis (OR=33 sitting), limited hip extension (OR=39 supine), or limited knee extension (OR=37 standing). Postural asymmetries correlated to hip dislocations: supine (rs=0.48), sitting (rs=0.40), standing (rs=0.41), and inability to change position: supine (rs=0.60), sitting (rs=0.73), and standing (rs=0.64). Conclusions Postural asymmetries were associated with scoliosis, hip dislocations, hip and knee contractures, and inability to change position. This article is commented on by Novak on page 974 of this issue. PMID:23834239
Can, Ata; Sarikaya, Ilker A; Yontar, Necip S; Erdogan, Ayse O; Gorgun, Baris; Erdogan, Fahri
2018-05-01
We argue that 1-stage bilaterally total hip arthroplasty (THA) could be acceptable in bilateral coxarthrosis because of high-riding developmental dysplasia of the hip (DDH). Sixty-nine cases (51 patients) of high-riding DDH in patients who underwent THA from 2010 to 2013 were reviewed. Patients were divided into 2 groups: unilateral (group 1) and 1-stage bilateral surgery (group 2). The clinical measurements were the visual analog scale and Harris Hip Score. The average follow-up was 37.3 months for group 1 and 38.8 months for group 2. The hospital stay time was 5.2 days in group 1 and 6.2 days in group 2 (P = .334). The mean Harris Hip Score and visual analog scale score were improved significantly after surgery for both groups, and there was no statistically significant difference (P = .988). There was no difference between groups 1 and 2 in terms of complications (P = .137). Our data confirm that 1-stage bilateral transverse osteotomy with THA is an effective method as unilateral and it does not increase the length of patients' hospital stays and features a low risk of postoperative complications in the treatment of patients with high-riding DDH. Copyright © 2017 Elsevier Inc. All rights reserved.
Porter, David; Michael, Shona; Kirkwood, Craig
2007-12-01
To investigate: (a) associations between the direction of scoliosis, direction of pelvic obliquity, direction of windswept deformity and side of hip subluxation/ dislocation in non-ambulant people with cerebral palsy; and (b) the lateral distribution of these postural asymmetries. Cross-sectional observational study. Posture management services in three centres in the UK. Non-ambulant people at level five on the gross motor function classification system for cerebral palsy. Direction of pelvic obliquity and lateral spinal curvature determined from physical examination, direction of windswept hip deformity derived from range of hip abduction/adduction, and presence/side of unilateral hip subluxation defined by hip migration percentage. A total of 747 participants were included in the study, aged 6-80 years (median 18 years 10 months). Associations between the direction of scoliosis and direction of pelvic obliquity, and between the direction of windswept hip deformity and side hip subluxation/dislocation were confirmed. A significant association was also seen between the direction of scoliosis and the direction of the windswept hip deformity (P<0.001) such that the convexity of the lateral spinal curve was more likely to be opposite to the direction of windsweeping. Furthermore, significantly more windswept deformities to the right (P=0.007), hips subluxed on the left (P=0.002) and lateral lumbar/lower thoracic spinal curves convex to the left (P=0.03) were observed. The individual asymmetrical postural deformities are not unrelated in terms of direction and not equally distributed to the left/right. A pattern of postural deformity was observed.
Michael, Shona; Kirkwood, Craig
2008-01-01
Objective: To investigate: (a) associations between the direction of scoliosis, direction of pelvic obliquity, direction of windswept deformity and side of hip subluxation/dislocation in non-ambulant people with cerebral palsy; and (b) the lateral distribution of these postural asymmetries. Design: Cross-sectional observational study. Setting: Posture management services in three centres in the UK. Subjects: Non-ambulant people at level five on the gross motor function classification system for cerebral palsy. Main measures: Direction of pelvic obliquity and lateral spinal curvature determined from physical examination, direction of windswept hip deformity derived from range of hip abduction/adduction, and presence/side of unilateral hip subluxation defined by hip migration percentage. Results: A total of 747 participants were included in the study, aged 6–80 years (median 18 years 10 months). Associations between the direction of scoliosis and direction of pelvic obliquity, and between the direction of windswept hip deformity and side hip subluxation/dislocation were confirmed. A significant association was also seen between the direction of scoliosis and the direction of the windswept hip deformity (P < 0.001) such that the convexity of the lateral spinal curve was more likely to be opposite to the direction of windsweeping. Furthermore, significantly more windswept deformities to the right (P = 0.007), hips subluxed on the left (P = 0.002) and lateral lumbar/lower thoracic spinal curves convex to the left (P = 0.03) were observed. Conclusions: The individual asymmetrical postural deformities are not unrelated in terms of direction and not equally distributed to the left/right. A pattern of postural deformity was observed. PMID:18042604
Adverse Outcomes in Infantile Bilateral Developmental Dysplasia of the Hip.
Morbi, Abigail H M; Carsi, Belen; Gorianinov, Vitalli; Clarke, Nicholas M P
2015-01-01
It is believed that bilateral developmental dysplasia of the hip (DDH) has poorer outcomes with higher rates of avascular necrosis (AVN) and reintervention, compared with unilateral DDH. However, there is limited evidence in the literature, with few studies looking specifically at bilateral cases. A retrospective review of 36 patients (72 hips) with >4 years of follow-up. Patient population included surgically treated DDH including late presentations and failures of conservative treatment. The dislocated hips underwent either simultaneous closed or 1 open and 1 closed, or sequential open reduction. AVN and secondary procedures were used as endpoints for analysis as well as clinical and radiologic outcomes. At the last follow-up, 33% of hips had radiologic signs of AVN. Those hips that had no ossific nucleus (ON) at the time of surgery had an odds ratio of developing AVN of 3.05 and a statistically significant association between the 2 variables, whereas open/closed or simultaneous/sequential reduction did not increase the risk for AVN. In addition, 45.8% of those hips required further surgery. The estimated odds ratio of needing additional surgery after simultaneous reduction was 4.04. Clinically, 79.2% of the hips were graded as McKay I, whereas radiologically only 38.8% were Severin I. The AVN rate in bilateral DDH treated surgically is greater than the rate noted in unilateral cases from the same institution undergoing identical protocols. There was no difference in AVN rates between simultaneous and sequential or between the first and second hip to be sequentially reduced. Presence of ON decreases the risk for AVN, suggesting that in bilateral cases, awaiting the appearance of the ON is an important tool to reduce the incidence of AVN. IV.
Hip pathology in Majewski osteodysplastic primordial dwarfism type II.
Karatas, Ali F; Bober, Michael B; Rogers, Kenneth; Duker, Angela L; Ditro, Colleen P; Mackenzie, William G
2014-09-01
Majewski osteodysplastic primordial dwarfism type II (MOPDII) is characterized by severe prenatal and postnatal growth failure with microcephaly, characteristic skeletal dysplasia, an increased risk for cerebrovascular disease, and insulin resistance. MOPDII is caused by mutations in the pericentrin (PCNT) gene and is inherited in an autosomal-recessive manner. This study aimed to determine the incidence of hip pathology in patients with molecularly confirmed MOPDII and to describe the functional outcomes of surgical treatment. Thirty-three enrolled patients had a clinical diagnosis of MOPDII. Biallelic PCNT mutations or absent pericentrin protein was confirmed in 25 of these patients. Twelve patients (7 female) had appropriate clinical and radiographic records at this institution and were included in this study. The data collected included age at presentation, age at surgery, sex, body weight and height, weight-bearing status at diagnosis, and the clinical examination. Four patients (31%) had coxa vara: 3 unilateral and 1 bilateral. Three unilateral patients had in situ pinning at a mean age 4 years. The patient with bilateral coxa vara had valgus osteotomy at the age of 5 years. Two children had bilateral hip dysplasia and subluxation with no surgery. One patient had bilateral developmental hip dislocations. The patient was treated by open reduction-spica cast and 2 years after surgery, coxa valga was noted. Another patient was diagnosed at an age of 12 years with bilateral avascular necrosis of the hips. Four patients did not have hip pathology. Hip pathology is common among children with MOPDII; coxa vara is the most frequent diagnosis. Routine clinical and radiographic hip evaluation is important. The capital femoral epiphysis appears to slip down along the shaft, giving the appearance of a proximal femoral epiphysiolysis. A hip diagnosed with slipped capital femoral epiphysis in early life may progress to severe coxa vara. Level IV.
Cho, Yoon J; Lee, Choong H; Chun, Young S; Rhyu, Kee H
2016-09-29
In this case series, we investigated the outcome of cementless total hip arthroplasty (THA) for advanced hip osteoarthritis in patients with residual poliomyelitis to evaluate its clinical usefulness for these patients. 11 unilateral cementless primary THA were performed to arthritic hips in patients with residual poliomyelitis. 7 were in paralytic and 4 were in nonparalytic limbs. The mean follow-up duration was 79.9 months. Retrospective clinical evaluations with various scores and radiological evaluations were made. Harris Hip Score, Western Ontario and McMaster Universities Arthritis Index (WOMAC) and Short-form (SF)-36 physical scales were significantly improved after the surgery. However, UCLA activity score and SF-36 mental scale were not. Because of remaining leg length discrepancies, all but 1 noted a residual limp. In nonparalytic hip, functional acetabular cup inclination during weight bearing significantly increased from installed inclination. Other than 1 case of posterior dislocation, no complications were observed. Although the overall result itself is excellent, THA for these patients cannot improve limp, physical activity and mental status. Surgeons should be aware of the change of the inclination of acetabular cup during mobilisation, especially for THA in contralateral hip.
Traumatic hip dislocation at a regional trauma centre in Nigeria.
Onyemaechi, N O C; Eyichukwu, G O
2011-01-01
Traumatic dislocation or fracture-dislocation of the hip is an orthopaedic emergency that is steadily increasing in incidence due to high-speed motor vehicular accidents. These injuries need to be recognized early and promptly treated to prevent morbidity and long-term complications. Some of the fundamental issues in the management of traumatic dislocations of the hip are the critical interval between injury and reduction, the type of reduction most suitable for various types of injury and the duration of immobilization that give the best results. This study was carried out at the National Orthopaedic Hospital Enugu, a regional trauma and orthopaedic centre in South-East Nigeria. The purpose of the study is to describe the pattern of presentation and to identify the factors that determine the long-term outcome in the treatment of traumatic dislocations and fracture-dislocations of the hip at Enugu, Nigeria. The case notes of all the patients that presented with traumatic dislocations and fracture-dislocations of the hip between January 2003 and December 2007 were reviewed. The information extracted and analyzed included the patients' demographics, etiology of injury, time interval before reduction, associated injuries, treatment offered, complications and follow-up. Thompson-Epstein classification was used to grade the posterior hip dislocations. The outcome of treatment was evaluated using the clinical and radiological criteria proposed by Epstein (1974). Three patients with incomplete data and two patients with central fracture dislocation were excluded from this study. Forty-eight patients with 50 hip dislocations were analyzed. The age range was 12 years to 67 years with a mean age of 34.8 years. Thirty-nine patients (81.3%) were males and 9 (18.7%) were females. Road-traffic accident was the leading cause of traumatic hip dislocation in this series, 44 cases (91.6%). Posterior dislocation occurred in 48 hips (96%) while anterior dislocation occurred in 2 hips (4%). Forty-seven hips (94%) were treated by primary closed reduction, two hips (4%) were treated with open reduction and one patient (2%) had Girdlestone excision arthroplasty. Thirty-six hips (73.5%) were reduced with 12 hours of the injury. Concomitant injuries were found in 37 patients (77%). The follow up period ranged from 10 months to 36 months with a mean follow up period of 15 months. Post-traumatic osteoarthritis occurred in 2 hips (4%) avascular necrosis of the femoral head was seen in 2 hips (4%). Five patients had sciatic nerve paresis while there was recurrence in one hip. No mortality was recorded. Traumatic dislocations and fracture-dislocations of the hip are severe injuries caused mostly by high-speed motor-vehicular accidents. Young adult males are most commonly affected, and there is a high rate of concomitant injuries. Excellent results can be achieved by early and stable closed reduction of these injuries with immobilization of the affected hips.
Pathak, Aditya C; Patil, Atul K; Sheth, Binoti; Bansal, Rohan
2012-01-01
Traumatic neglected dislocations of hip in children are rare entity. Neglected traumatic dislocations of hip in children along with heterotopic ossification are still rare. Post traumatic neglected hip dislocations are to be diagnosed as early as possible and have to be treated with precision and aggression as the outcome of treatment for the same is not predictable. 5 year female with post-traumatic neglected hip dislocation with heterotopic ossification forming a pseudoacetabulum postero-superiorly in which femur head was lodged. The girl was operated by open reduction using Moore's Posterior approach and showed good results. Here is a mention of a rare case with a good 18 months follow up with no complication. Post-traumatic neglected posterior hip dislocation mostly requires open reduction and relocation of femoral head in original acetabulum with concentric reduction. Heterotopic ossification is a rare but known complication of traumatic dislocation of hip in children. Good results can be achieved in such cases and regular follow-up of patient is required post-operatively.
Ipsilateral hip and knee dislocation: Case report and review of literature
Sharma, Gaurav; Chahar, Deepak; Sreenivasan, Ravi; Verma, Nikhil; Pankaj, Amite
2016-01-01
Hip and knee dislocations are not uncommon but simultaneous ipsilateral dislocation of the hip and knee joint is rare; consequently, there is an inadequate amount of literature on the subject. We identified only 11 such cases reported in English literature. In the present report, we describe the case of a 23-year-old male patient who presented with ipsilateral hip and knee dislocation on the right side after being involved in a road traffic accident. The hip dislocation was associated with a posterior wall acetabular fracture. The hip as well as the knee joints was reduced in the emergency bay. The patient underwent an urgent fixation of the posterior wall acetabular fracture with delayed ligament reconstruction for the knee dislocation. At one-year follow-up, he had no pain in the hip or knee. There was grade 1 posterior sag but no symptoms of knee instability. Radiographs revealed no evidence of avascular necrosis or arthritis of the femoral head. The normal treatment protocol for individual injury is affected by the simultaneous occurrence of hip and knee dislocation. PMID:27182149
A Rare Case of Neglected Traumatic Anterior Dislocation of Hip in a Child.
Mootha, Aditya Krishna; Mogali, Kasi Viswanadam
2016-01-01
Post traumatic hip dislocations are very rare in children. Neglected anterior hip dislocations in children are not described in literature so far. Here, we present a case of 6 weeks old anterior hip dislocation successfully managed by open reduction. A 9-year-old male child presented with neglected anterior hip dislocation on left side. Open reduction carried out through direct anterior approach to hip. Congruent reduction is achieved. At final follow up of 1 year, the child had unrestricted activities of daily living and no radiological signs of osteonecrosis or any joint space reduction. There is paucity of literature over neglected post traumatic anterior hip dislocations in children. The treatment options vary from closed reduction after heavy traction to sub trochanteric osteotomy. However, we feel that open reduction through direct anterior approach is the preferred mode of management whenever considered possible.
Sariali, Elhadi; Klouche, Shahnez; Mamoudy, Patrick
2012-07-01
The components position is a major factor under the surgeon's control in determining the risk of dislocation post total hip arthroplasty. The aim of this study was to investigate the proper three-dimensional components position including the centre of rotation in the case of anterior dislocation. Among 1764 consecutive patients who underwent total hip arthroplasty using a direct anterior approach, 27 experienced anterior dislocation. The three-dimensional hip anatomy was investigated in 12 patients who were paired with 12 patients from the same initial cohort who did not experience dislocation and also with 36 control patients with osteoarthritis. A pelvic Cartesian referential was defined to perform the acetabular analysis. The coordinates were expressed as percentages of the pelvic width, height and depth. The anteversion angles were measured. The hip centre of rotation was significantly shifted medially and posteriorly in the dislocation group when compared to the non-dislocation group and also to the control group. There was no significant difference in component angular position between the dislocation-group and the non-dislocation group. However, the stem anteversion in the dislocation group was increased in comparison to the mean natural femoral anteversion of the control group. A medial and posterior displacement of the hip rotation centre was found to correlate to anterior dislocation post total hip arthoplasty. These results suggest the importance of an accurate restoration of the centre of rotation, whilst avoiding an excessive acetabular reaming which may induce a medial and a posterior displacement. III comparative non randomised. Copyright © 2011 Elsevier Ltd. All rights reserved.
Hip arthroscopy versus open surgical dislocation for femoroacetabular impingement
Zhang, Dagang; Chen, Long; Wang, Guanglin
2016-01-01
Abstract Background: This meta-analysis aims to evaluate the efficacy and safety of hip arthroscopy versus open surgical dislocation for treating femoroacetabular impingement (FAI) through published clinical trials. Methods: We conducted a comprehensive literature search using PUBMED, EMBASE, and the Cochrane Central Register of Controlled Trials databases for relevant studies on hip arthroscopy and open surgical dislocation as treatment options for FAI. Results: Compared with open surgical dislocation, hip arthroscopy resulted in significantly higher Nonarthritic Hip Scores (NAHS) at 3- and 12-month follow-ups, a significant improvement in NAHS from preoperation to 3 months postoperation, and a significantly lower reoperation rate. Open surgical dislocation resulted in a significantly improved alpha angle by the Dunn view in patients with cam osteoplasty from preoperation to postoperation, compared with hip arthroscopy. This meta-analysis demonstrated no significant differences in the modified Harris Hip Score, Hip Outcome Score-Activities of Daily Living, or Hip Outcome Score-Sport Specific Subscale at 12 months of follow-up, or in complications (including nerve damage, wound infection, and wound dehiscence). Conclusion: Hip arthroscopy resulted in higher NAHS and lower reoperation rates, but had less improvement in alpha angle in patients with cam osteoplasty, than open surgical dislocation. PMID:27741133
Bakalakos, Matthaios; Benetos, Ioannis S; Rozis, Meletios; Vlamis, John; Pneumaticos, Spiros
2018-06-02
The majority of injuries during a football game are contusions, sprains and/or strains in the thigh, knee and ankle. Hip dislocations account for 2-5% of total hip dislocations, and they can be posterior or anterior. Major complications of traumatic hip dislocation include avascular necrosis of femoral head, secondary osteoarthritis, sciatic nerve injury and heterotopic ossification. On the occasion of a case of a 33-year-old football player, who suffered a posterior hip dislocation, associated with a posterior wall fracture of the acetabulum, while playing football, we review the literature and analyze the various mechanisms of injury, the possible complications and the management including surgery and rehabilitation.
Flynn, John M; Ramirez, Norman; Betz, Randal; Mulcahey, Mary Jane; Pino, Franz; Herrera-Soto, Jose A; Carlo, Simon; Cornier, Alberto S
2010-01-01
A syndrome of children with short stature, bilateral hip dislocations, radial head dislocations, carpal coalitions, scoliosis, and cavus feet in Puerto Rican children, was reported by Steel et al in 1993. The syndrome was described as a unique entity with dismal results after conventional treatment of dislocated hips. The purpose of this study is to reevaluate this patient population with a longer follow-up and delineate the clinical and radiologic features, treatment outcomes, and the genetic characteristics. This is a retrospective cohort study of 32 patients in whom we evaluated the clinical, imaging data, and genetic characteristics. We compare the findings and quality of life in patients with this syndrome who have had attempts at reduction of the hips versus those who did not have the treatment. Congenital hip dislocations were present in 100% of the patients. There was no attempt at reduction in 39% (25/64) of the hips. In the remaining 61% (39/64), the hips were treated with a variety of modalities fraught with complications. Of those treated, 85% (33/39) remain dislocated, the rest of the hips continue subluxated with acetabular dysplasia and pain. The group of hips that were not treated reported fewer complaints and limitation in daily activities compared with the hips that had attempts at reduction. Steel syndrome is a distinct clinical entity characterized by short stature, bilateral hip and radial head dislocation, carpal coalition, scoliosis, cavus feet, and characteristic facial features with dismal results for attempts at reduction of the hips. Prognostic Study Level II.
Farkas, Gary J; Schlink, Bryan R; Fogg, Louis F; Foucher, Kharma C; Wimmer, Markus A; Shakoor, Najia
2018-05-01
Little is known about the loading patterns in unilateral hip osteoarthritis (OA) and their relationship to radiographic severity and pain. We aimed to examine the loading patterns at the hips of those with unilateral symptomatic hip OA and identify associations between radiographic severity and pain with loading alterations. Sixty-one subjects with symptomatic unilateral hip OA underwent gait analyses and evaluation for radiographic severity (Kellgren-Lawrence [KL]-grade) and pain (visual analogue scale) at bilateral hips. Hip OA subjects had greater range of motion and higher hip flexion, adduction, internal and external rotation moments at the contralateral, asymptomatic hip compared to the ipsilateral hip ( p < 0.05). Correlations were noted between increasing KL-grade and increasing asymmetry of contralateral to ipsilateral hip loading ( p < 0.05). There were no relationships with pain and loading asymmetry. Unilateral symptomatic hip OA subjects demonstrate asymmetry in loading between the hips, with relatively greater loads at the contralateral hip. These loading asymmetries were directly related to the radiographic severity of symptomatic hip OA and not with pain. Additional research is needed to determine the role of gait asymmetries in disease progression.
Arjun, R H H; Kumar, Vishal; Saibaba, Balaji; John, Rakesh; Guled, Uday; Aggarwal, Sameer
2016-09-01
The incidence of traumatic hip dislocations in children is rising in this fast developing world along with increasing numbers of high-velocity road traffic accidents. Anterior dislocation of the hip has a lower incidence compared with posterior dislocation of the hip. We encountered a rare case of the obturator type of anteriorly dislocated hip associated with ipsilateral fracture of the shaft femur in an 11-year-old child. This is a highly unusual injury combination and the mechanism of injury is obscure. Only two similar cases have been reported in the English literature to date. Closed reduction of the hip using a hitherto undescribed technique and an intramedullary interlocking nail was performed in this case. At 6 months of follow-up, the fracture shaft femur has united and the child is bearing full weight on the limb.
A Rare Case of Morel-Lavallee Syndrome Complicating an Anterior Dislocation of Hip Joint.
Nekkanti, Supreeth; Vijay, C; Theja, Sujana; Shankar, R Ravi; Verma, Anubhav
2016-01-01
Hip dislocations are serious injuries as hip joint is an extremely stable joint. It requires a significant amount of force to produce such an injury. Anterior dislocations are uncommon. Potential complications of anterior hip dislocations are a neurovascular injury to femoral vessels or acetabular fractures. We report a rare late complication of Morel-Lavallee syndrome occurring 3 weeks after an anterior dislocation of the hip in a 43-year-old male. The patient presented to us with history. Morel-Lavallee syndrome is a rare complication. However if diagnosed early can be successfully treated with minimal burden to the patient. The authors recommend surgeons to have a high index of suspicion for this syndrome and a stringent follow-up examination of the patient.
Ebraheim, Nabil A; Liu, Jiayong; Ramineni, Satheesh K; Liu, Xiaochen; Xie, Joe; Hartman, Ryan G; Goel, Vijay K
2009-11-01
Many investigators have conducted studies to determine the biomechanics, causes, complications and treatment of unilateral facet joint dislocation in the cervical spine. However, there is no quantitative data available on morphological changes in the intervertebral foramen of the cervical spine following unilateral facet joint dislocation. These data are important to understand the cause of neurological compromise following unilateral facet joint dislocation. Eight embalmed human cadaver cervical spine specimens ranging from level C1-T1 were used. The nerve roots of these specimens at C5-C6 level were marked by wrapping a 0.12mm diameter wire around them. Unilateral facet dislocation at C5-C6 level was simulated by serially sectioning the corresponding ligamentous structures. A CT scan of the specimens was obtained before and after the dislocation was simulated. A sagittal plane through the centre of the pedicle and facet joint was constructed and used for measurement. The height and area of the intervertebral foramen, the facet joint space, nerve root diameter and area, and vertebral alignment both before and after dislocation were evaluated. The intervertebral foramen area changed from 50.72+/-0.88mm(2) to 67.82+/-4.77mm(2) on the non-dislocated side and from 41.39+/-1.11mm(2) to 113.77+/-5.65mm(2) on the dislocated side. The foraminal heights changed from 9.02+/-0.30mm to 10.52+/-0.50mm on the non-dislocated side and 10.43+/-0.50mm to 17.04+/-0.96mm on the dislocated side. The facet space area in the sagittal plane changed from 6.80+/-0.80mm(2) to 40.02+/-1.40mm(2) on the non-dislocated side. The C-5 anterior displacement showed a great change from 0mm to 5.40+/-0.24mm on the non-dislocated side and from 0mm to 3.42+/-0.20mm on the dislocated side. Neither of the nerve roots on either side showed a significant change in size. The lack of change in nerve root area indicates that the associated nerve injury with unilateral facet joint dislocation is probably due to distraction rather than due to direct nerve root compression.
Howie, Donald W; Holubowycz, Oksana T; Middleton, Robert
2012-06-20
The use of larger femoral heads has been proposed to reduce the risk of dislocation after total hip arthroplasty, but there is a lack of evidence to support this proposal. The aim of this multicenter randomized controlled trial was to determine whether the incidence of dislocation one year after total hip arthroplasty is significantly lower in association with the use of a 36-mm femoral head articulation as compared with a 28-mm articulation. Six hundred and forty-four middle-aged and elderly patients undergoing primary or revision arthroplasty were randomized intraoperatively to receive either a 36 or 28-mm metal femoral head on highly cross-linked polyethylene. Patients who were at high risk of dislocation (including those with dementia and neuromuscular disease) and those undergoing revision for the treatment of recurrent hip dislocation or infection were excluded. Patients were stratified according to other potential risk factors for dislocation, including diagnosis and age. Diagnosis of hip dislocation required confirmation by a physician and radiographic evidence of a dislocation. Overall, at one year of follow-up, hips with a 36-mm femoral head articulation had a significantly lower incidence of dislocation than did those with a 28-mm articulation (1.3% [four of 299] compared with 5.4% [seventeen of 316]; difference, 4.1% [95% confidence interval, 1.2% to 7.2%]) when controlling for the type of procedure (primary or revision) (p = 0.012). The incidence of dislocation following primary arthroplasty was also significantly lower for hips with a 36-mm femoral head articulation than for those with a 28-mm articulation (0.8% [two of 258] compared with 4.4% [twelve of 275]; difference, 3.6% [95% confidence interval, 0.9% to 6.8%]) (p = 0.024). The incidence of dislocation following revision arthroplasty was 4.9% (two of forty-one) for hips with a 36-mm articulation and 12.2% (five of forty-one) for hips with a 28-mm articulation; this difference was not significant with the relatively small sample size of the revision group (difference, 7.3% [95% confidence interval, -5.9% to 21.1%]) (p = 0.273). Compared with a 28-mm femoral head articulation, a larger 36-mm articulation resulted in a significantly decreased incidence of dislocation in the first year following primary total hip arthroplasty. However, before a 36-mm metal-on-highly cross-linked polyethylene articulation is widely recommended, the incidence of late dislocation, wear, periprosthetic osteolysis, and liner fracture should be established.
Kim, Soo-Yong; Kang, Min-Hyeok; Kim, Eui-Ryong; Jung, In-Gui; Seo, Eun-Young; Oh, Jae-Seop
2016-10-01
The aim of this study was to investigate the effects of additional isometric hip adduction during the plank exercise on the abdominal muscles. Twenty healthy young men participated in this study. Surface electromyography (EMG) was used to monitor the activity of the bilateral rectus abdominis (RA), the internal oblique (IO), and the external oblique (EO) muscles. The participants performed three types of plank exercise; the standard plank exercise, the plank exercise with bilateral isometric hip adduction, and the plank exercise with unilateral isometric hip adduction. All abdominal muscle activity was significantly increased during the plank exercise combined with the bilateral and unilateral isometric hip adduction compared with the standard plank exercise (p<0.05). Bilateral IO, EO, and left RA muscle activity was significantly increased during the unilateral isometric hip adduction compared with the bilateral isometric hip adduction (p<0.05). These findings suggest that additional isometric hip adduction during the plank exercise could be a useful method to enhance abdominal muscle activity. In particular, the unilateral isometric hip adduction is a more beneficial exercise than the bilateral isometric hip adduction. Copyright © 2016 Elsevier Ltd. All rights reserved.
Could larger diameter of 4th generation ceramic bearing decrease the rate of dislocation after THA?
Lee, Young-Kyun; Ha, Yong-Chan; Jo, Woo-Lam; Kim, Tae-Young; Jung, Woon-Hwa; Koo, Kyung-Hoi
2016-05-01
Fourth generation (Delta) ceramic bearing was developed to reduce dislocation after total hip arthroplasty (THA) by increasing the head diameter. We tested a hypothesis that 32/36 mm Delta ceramic bearing decreases the dislocation rate. We also evaluated ceramic-related complications and early outcome of this thin liner-on-large head ceramic bearing. We performed a prospective study on patients who underwent THA with use of 32/36 mm Delta ceramic bearing. The dislocation rate was compared with the historical dislocation rate of third generation 28 mm ceramic bearing. We also evaluated ceramic fracture, squeak, short-term results and survival. Follow-up period was minimum 2 years. Between April 2010 and February 2012, we enrolled 250 consecutive patients (278 hips). All patients received cementless prostheses. Four patients (4 hips) who received metal shells ≤ 46 mm and 28 mm heads were excluded. Three patients died and 2 patients were lost within 2 years. The remaining 241 patients (269 hips) were followed for 24-46 months. There were 142 men (161 hips) and 99 women (108 hips) with a mean age of 53.7 years (range, 17-75 years) at the index operation. Dislocation occurred in three hips (1.1%). An old age was a risk factor for dislocation. Ceramic fracture and squeaking did not occur in any patient. Mean Harris hip score was 90.3 points at the latest follow-up. All acetabular and femoral components had bone-ingrowth stability. No hip had detectable wear or osteolysis. The survival was 99.3% in the best case scenario and 97.8% in the worst at 48 months. Total hip arthroplasty with use of 32/36 mm Delta ceramic bearing showed lower incidence of hip dislocation compared with 28 mm third generation ceramic bearing. A caution should be paid to prevent a fall in senile patients even though a large head is used. The short-term results of THA with this type of ceramic articulation are encouraging and we did not find any ceramic-related complications. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
Ho, Ki Wai Kevin; Whitwell, George S; Young, Steve K
2012-07-01
We report how changes to our total hip arthroplasty (THA) surgical practise lead to a decrease in early hip dislocation rates. Group B consisted of 421 consecutive primary THA operations performed via a posterior approach. The operative technique included a meticulous repair of the posterior capsule, alignment of the acetabular cup with the transverse acetabular ligament (TAL) and a 36-mm-diameter femoral head. We compared the dislocation rates and cost implications of this technique to a historical control Group A consisting of 389 patients. The control group had their THA performed with no repair of the capsule, no identification of the TAL and all received a 28-mm-diameter head. Our primary outcome is the rate of early hip dislocation and we hypothesised that we can reduce the rate of early hip dislocation with this new regime. In Group B there were no early dislocations (within 6 months) and two (0.5 %) dislocations within 18 months; minimum follow-up time was 18 months with a range of (18-96 months). This compared to a 1.8 % early dislocation rate and a 2.6 % rate at 18 months in Group A; minimum follow-up time was 60 months with a range of (60-112 months). These results were statistically significant (p = 0.006). We suggest that when primary hip arthroplasty is performed through a posterior approach, a low early dislocation rate can be achieved using the described methods.
Kellam, Patrick; Ostrum, Robert F
2016-01-01
To determine the incidence rate and associative factors for the development of avascular necrosis (AVN) and posttraumatic arthritis (PTA) after traumatic hip dislocation and time to reduction. A comprehensive search of databases including PubMed, Cochrane Database, and Embase through April 2014 for English articles reporting complications of AVN and PTA after hip dislocation was performed. Inclusion criteria were English-only studies, a patient population of adults, study outcomes of AVN and/or PTA reported, and articles reported at least type I dislocations. Two authors independently extracted data from the selected studies and the data collected were compared to verify agreement. Random-effects models were used for meta-analysis. The overall event rate of AVN and PTA was calculated and stratified based on Thompson-Epstein of the hip dislocation. Odds ratios were calculated for those articles that reported rates of AVN based on time to reduction. For anterior dislocations, the event rate for AVN ranged from 0.087 to 0.333, whereas the event rate for PTA ranged from 0.125 to 0.700. Analysis of posterior dislocations revealed that the event rate for AVN ranged from 0.106 to 0.430; additionally, the event rate for PTA ranged from 0.194 to 0.586. For posterior hip dislocations and type I and II anterior dislocations, the severity of the injury correlates with an increase in the development of AVN and PTA. The odds ratio of AVN for those hip dislocations reduced after 12 hours versus those reduced before 12 hours was 5.627. Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence.
[Acute traumatic and especially neglected traumatic hip dislocations are very rare in children].
Fernandez, F F; Wirth, T; Eberhardt, O
2012-09-01
We report about the first hip arthroscopies of extracapsular neglected hip dislocations with concomitant injuries in two children (2 and 4 years old). The major problem of traumatic hip dislocation is avascular necrosis. Further problems are possible concomitant injuries. It is important not to cause further damage by therapeutic procedures. In a 4-year-old child the hip could be reduced under visualization and in a 2-year-old child with epiphyseal fracture the extent of the operation could be reduced. In both children large avulsion injuries of the ligamentum capitis femoris could be resected via hip arthroscopy. Hip arthroscopy can reduce surgical morbidity considerably and can possibly contribute to prevention of the feared avascular necrosis of the femoral head.
Porter, David; Michael, Shona; Kirkwood, Craig
2008-09-01
It has been suggested that asymmetrical positioning of an infant with reduced mobility may lead to postural deformity becoming established over time. However, evidence to support or question this line of thinking is lacking. Therefore, the aim of this retrospective cohort study was to test the association between asymmetrical positioning in the first 12 months of life and the subsequent direction of postural deformity in non-ambulant people with cerebral palsy. The direction of scoliosis, pelvic obliquity and windswept hip pattern and also the side of unilateral hip subluxation/dislocation were determined for 246 young people ranging in age from 1 year and 2 months to 19 years (median age 10 years and 3 months). Parents/carers of the participants were interviewed to establish holding and feeding positions and preferred lying posture adopted in early life. Univariate analyses and multivariate logistic regression analyses were carried out. The study provided evidence of an association between asymmetrical lying posture adopted in the first year of life and the direction of the subsequent pattern of postural deformity. If the child's head had been rotated to the right during supine lying, it was more likely that the scoliosis would be convex to the left, pelvic obliquity would be lower on the left, windswept hip pattern would be to the right and hip subluxation/dislocation would occur on the left. The likelihood of the deformities occurring in the same direction was also increased if consistent side lying on the right had been preferred. Clinicians should be aware of positioning for children with severe disabilities particularly those who prefer supine lying with their head rotated to the side and those who prefer consistent side lying.
Surgical Dislocation of the Hip for the Treatment of Pre-Arthritic Hip Disease.
Beaulé, Paul E; Singh, Amardeep; Poitras, Stéphane; Parker, Gillian
2015-09-01
The purpose of this study was to report the clinical results of surgical dislocation of the hip in the treatment of pre-arthritic hip disease. Between 2005 and 2010, eighty-two patients (89 hips) underwent a surgical dislocation of the hip at a mean age of 30.5 years (range 14.8-51.7); 10 females and 72 males. At a mean follow-up of 7.1 years (range 5-9.6) clinical function improved significantly. 6 patients were converted to total hip arthroplasty and 3 patients underwent an arthroscopy and an additional three patients had >1mm of joint space narrowing at latest follow-up giving us a 9-year cumulative Kaplan-Meier survivorship of 86.4% (CI, 79% to 94%). Thirty-four patients underwent internal fixation removal at a mean of 12.0 months (range 0.3-40.8 months). Although effective in the treatment of early hip disease, the surgical dislocation approach carries a high re-operation rate for removal of internal fixation; consequently, less invasive approaches should be considered for less complex deformities. Copyright © 2015 Elsevier Inc. All rights reserved.
Unilateral vs bilateral hip bone mineral density measurement for the diagnosis of osteoporosis.
Ikegami, Shota; Kamimura, Mikio; Uchiyama, Shigeharu; Mukaiyama, Keijiro; Kato, Hiroyuki
2014-01-01
It has not been established whether unilateral or bilateral hip dual-energy X-ray absorptiometry (DXA) is preferable for the diagnosis of osteoporosis. We investigated the discordance in DXA measurements in bilateral hips to determine whether unilateral DXA is valid for osteoporosis diagnosis. The subjects were 2964 Japanese patients without a previous diagnosis of primary osteoporosis. We measured bilateral femoral bone mineral density (BMD) and calculated indices, related to the unilateral results, for predicting contralateral hip osteoporosis. A likelihood ratio (LR) of a negative test (LR [-]) of less than 0.2 was considered to exclude the diagnosis. In the normal spinal BMD group, the sensitivity of unilateral DXA for women was 27-73% and LR (-) was 0.28-0.73; the sensitivity for men was 0-50% and LR (-) was 0.51-1.00; the diagnosis of contralateral osteoporosis was not excluded. Sensitivity increased and LR (-) increased with worsening spinal BMD status; however, LR (-) did not meet the cutoff for exclusion. We could exclude unilateral hip osteoporosis, in women only, by performing contralateral femoral DXA; this necessitated lowering the T-score cutoff from -2.5 to -2.0. Unilateral femoral DXA is not useful for excluding the diagnosis of contralateral hip osteoporosis. Copyright © 2014 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.
Guyen, Olivier; Pibarot, Vincent; Vaz, Gualter; Chevillotte, Christophe; Carret, Jean-Paul; Bejui-Hugues, Jacques
2007-09-01
We performed a retrospective study on 167 primary total hip arthroplasty (THA) procedures in 163 patients at high risk for instability to assess the reliability of unconstrained tripolar implants (press-fit outer metal shell articulating a bipolar polyethylene component) in preventing dislocations. Eighty-four percent of the patients had at least 2 risk factors for dislocation. The mean follow-up length was 40.2 months. No dislocation was observed. Harris hip scores improved significantly. Six hips were revised, and no aseptic loosening of the cup was observed. The tripolar implant was extremely successful in achieving stability. However, because of the current lack of data documenting polyethylene wear at additional bearing, the routine use of tripolar implants in primary THA is discouraged and should be considered at the present time only for selected patients at high risk for dislocation and with limited activities.
Surgical hip dislocation for treatment of cam femoroacetabular impingement.
Chaudhary, Milind M; Chaudhary, Ishani M; Vikas, K N; KoKo, Aung; Zaw, Than; Siddhartha, A
2015-01-01
Cam femoroacetabular impingement is caused by a misshapen femoral head with a reduced head neck offset, commonly in the anterolateral quadrant. Friction in flexion, adduction and internal rotation causes limitation of the hip movements and pain progressively leading to labral and chondral damage and osteoarthritis. Surgical hip dislocation described by Ganz permits full exposure of the hip without damaging its blood supply. An osteochondroplasty removes the bump at the femoral head neck junction to recreate the offset for impingement free movement. Sixteen patients underwent surgery with surgical hip dislocation for the treatment of cam femoroacetabular impingement by open osteochondroplasty over last 6 years. Eight patients suffered from sequelae of avascular necrosis (AVN). Three had a painful dysplastic hip. Two had sequelae of Perthes disease. Three had combined cam and pincer impingement caused by retroversion of acetabulum. All patients were operated by the trochanteric flip osteotomy with attachments of gluteus medius and vastus lateralis, dissection was between the piriformis and gluteus minimus preserving the external rotators. Z-shaped capsular incision and dislocation of the hip was done in external rotation. Three cases also had subtrochanteric osteotomy. Two cases of AVN also had an intraarticular femoral head reshaping osteotomy. Goals of treatment were achieved in all patients. No AVN was detected after a 6 month followup. There were no trochanteric nonunions. Hip range of motion improved in all and Harris hip score improved significantly in 15 of 16 cases. Mean alpha angle reduced from 86.13° (range 66°-108°) to 46.35° (range 39°-58°). Cam femoroacetabular Impingement causing pain and limitation of hip movements was treated by open osteochondroplasty after surgical hip dislocation. This reduced pain, improved hip motion and gave good to excellent results in the short term.
Miyake, Takahito; Kanda, Akio; Morohashi, Itaru; Obayashi, Osamu; Mogami, Atsuhiko; Kaneko, Kazuo
2017-06-01
Bipolar hip arthroplasty is a good option for treating femoral neck fractures, although some contraindications have been indicated. We report a case of intraoperative dislocation of the trial bipolar cup into the pelvis during bipolar hip arthroplasty. A 74-year-old woman underwent bipolar hip arthroplasty for a femoral neck fracture (AO31-B2). She was placed in a lateral decubitus position, and a direct lateral approach was used. During intraoperative trial reduction, the trial bipolar cup became disengaged and dislocated into the anterior space of hip joint. Several attempts to retrieve it failed. The permanent femoral component was inserted, and the wound was closed. The patient was repositioned supine to allow an ilioinguinal approach, and the component was easily removed. She had an uneventful, good recovery. Several cases of intraoperative dislocation of the femoral trial head during total hip arthroplasty have been reported, this is the first report of dislocation of a bipolar trial cup. A previous report described difficulty retrieving a trial cup. We easily removed our trial cup using another approach. It is vital to plan systematically for this frustrating complication.
Congential dislocation of the hip and adult low back pain: a report of three cases
Kitchen, Robert G; Mierau, Dale; Cassidy, David; Dupuis, Pierre
1988-01-01
Congenital dislocation of the hip (CDH) in an adult can accompany or cause mechanical low-back pain. This in turn, can create confusion in making the proper diagnosis. The mechanical alterations caused by CDH create an added strain to the lumbosacral spine. Manipulative treatment for back pain in these patients must not subject the dislocated hips to undue torque. ImagesFigure 1Figure 2Figure 3Figure 4aFigure 4b
Xu, Ning; Sun, Junying; Zhao, Xijiang; Wang, Tao
2016-01-01
To investigate the application and effectiveness of the biological type acetabular cup(diameter < 44 mm) in adult Crowe type IV developmental dysplasia of the hip (DDH). Between April 2001 andAugust 2013, biological type acetabular cup was used in total hip arthroplasty for the treatment of Crowe type IV DDH in16 cases (20 hips). There were 3 males and 13 females, aged 31-69 years (mean, 49 years). Unilateral hip was involved in 12cases, and bilateral hips in 4 cases. The patients showed pain of the hip joint and inequality of lower limb (shortening ofaffected limb 1.8-6.0 cm in length, 3.5 cm on average). Acetabular deformity, the relationship and the severity of femoralhead dislocation were comfirmed on the X-ray films. The preoperative Harris score was 34.0 ± 6.9. All patientsachieved healing of incision by first intention, with no complication of infection or neurovascular injury. Sixteen caseswere followed up 4-12 years (mean, 7.5 years). At 2 weeks after operation, dislocation occurred in 2 cases, and were fixedwith plaster for 3 weeks after reduction of the hip. Postoperative X-ray films showed complete reduction of femoral head;the average acetabular coverage of the cup of the weight-bearing area was 98.5% (range, 98.2%-99.1%). The cup from theRanawat triangle was 4.6-7.0 mm (mean, 5.8 mm) in medial shifting, and was 4.5-7.9 mm (mean, 6.2 mm) in elevation,it located at cup lateral surface area inside the iliopectineal line and the Kohler line (< 40%); the cup abduction angle was(45 ± 5)degrees, and the anteversion angle was (10 ± 5)degrees. The other patients had no prosthesis loosening except 1 patient havingextensive acetabular prosthesis loosening because of acetabular osteolysis at 12 years after operation. The hip Harris scorewas significantly improved to 85.0 ± 7.5 at 1 year after operation (t = 14.34, P = 0.01). The acetabular grindingprocess to retain enough bone combined with a small cup of-biological prosthesis treating adult Crowe type IV DDH has theadvantages of satisfactory coverage and initial acetabular fixation, so good early and mid-term effectiveness can be obtained.
Traumatic fracture-dislocation of the hip following rugby tackle: a case report.
Venkatachalam, Santosh; Heidari, Nima; Greer, Tony
2009-12-15
Posterior fracture-dislocation of hip is uncommonly encountered in rugby injuries. We report such a case in an adult while playing rugby. The treating orthopaedician can be caught unaware and injuries in such sports can be potentially misdiagnosed as hip sprains. Immediate reduction of the dislocation was performed in theatres. The fracture was fixed with two lag screws and a neutralization plate. This led to early rehabilitation and speedy recovery with return to sporting activities by 12 months.
Traumatic fracture-dislocation of the hip following rugby tackle: a case report
2009-01-01
Posterior fracture-dislocation of hip is uncommonly encountered in rugby injuries. We report such a case in an adult while playing rugby. The treating orthopaedician can be caught unaware and injuries in such sports can be potentially misdiagnosed as hip sprains. Immediate reduction of the dislocation was performed in theatres. The fracture was fixed with two lag screws and a neutralization plate. This led to early rehabilitation and speedy recovery with return to sporting activities by 12 months. PMID:20003496
Zhou, Yu; Zhou, Zhenyu; Liu, Lifeng; Cao, Xuecheng
2018-03-21
Skeletal and soft tissue damage are often associated with unilateral facet dislocations, which undoubtedly lead to instability of the spine and further increase difficulties in cervical reduction. This type of irreducible facet dislocation is usually accompanied with potential catastrophic consequences including neurological deficit and severe disability. Therefore, a consistent and evidence-based treatment plan is imperative. The literature regarding the management of traumatic unilateral locked cervical facet dislocations was reviewed. Two patient cases (a 30-year-old Asian man and a 25-year-old Asian woman) who suffered irreducible cervical facet dislocations were presented. These two patients received surgical treatments including posterior reduction by poking facet joints, adjacent spinous process fixation by wire rope banding, anterior plate fixation, and intervertebral fusion after the failure of skull traction and closed reduction. At the postoperative 24-month follow-up, intervertebral fusion was achieved and our patients' neurological status improved based on the American Spinal Injury Association scale, compared with their preoperative status. Unilateral facet joint dislocations of subaxial cervical spine are difficult to reduce when complicated with posterior facet fractures or ligamentous injury. Magnetic resonance imaging can be beneficial for identifying ventral and dorsal compressive lesions, as well as ligamentous or capsule rupture. The combination of posterior reduction and anterior fixation with fusion has advantages in terms of clinical safety, ease of operation, and less iatrogenic damage.
Shindle, Michael K.; Kelly, Bryan T.
2010-01-01
With the improvements in flexible instrumentation, hip arthroscopy is being increasingly used to treat a variety of hip pathology, including labral tears. However, up to this point, there has not been a case report of an anterior and a posterior labral tear successfully repaired arthroscopically. We present a case report of a 27-year-old male firefighter who presented to our institution with an anterior and posterior labral tear, as well as a cam lesion and loose body, following a traumatic hip dislocation. The purpose of this case report is to illustrate that both anterior and posterior labral tears can be repaired using hip arthroscopy. Anterior and posterior labral tears can be caused by a traumatic hip dislocation, and both can be successfully repaired using arthroscopic techniques. PMID:21886540
NASA Astrophysics Data System (ADS)
Liu, Xin; Lu, Hongbing; Chen, Hanyong; Zhao, Li; Shi, Zhengxing; Liang, Zhengrong
2009-02-01
Developmental dysplasia of the hip is a congenital hip joint malformation affecting the proximal femurs and acetabulum that are subluxatable, dislocatable, and dislocated. Conventionally, physicians made diagnoses and treatments only based on findings from two-dimensional (2D) images by manually calculating clinic parameters. However, anatomical complexity of the disease and the limitation of current standard procedures make accurate diagnosis quite difficultly. In this study, we developed a system that provides quantitative measurement of 3D clinical indexes based on computed tomography (CT) images. To extract bone structure from surrounding tissues more accurately, the system firstly segments the bone using a knowledge-based fuzzy clustering method, which is formulated by modifying the objective function of the standard fuzzy c-means algorithm with additive adaptation penalty. The second part of the system calculates automatically the clinical indexes, which are extended from 2D to 3D for accurate description of spatial relationship between femurs and acetabulum. To evaluate the system performance, experimental study based on 22 patients with unilateral or bilateral affected hip was performed. The results of 3D acetabulum index (AI) automatically provided by the system were validated by comparison with 2D results measured by surgeons manually. The correlation between the two results was found to be 0.622 (p<0.01).
Furuhashi, Hiroki; Togawa, Daisuke; Koyama, Hiroshi; Hoshino, Hironobu; Yasuda, Tatsuya; Matsuyama, Yukihiro
2017-05-01
Several reports have indicated that anterior dislocation of total hip arthroplasty (THA) can be caused by spinal degenerative changes with excessive pelvic retroversion. However, no reports have indicated that posterior dislocation can be caused by fixed pelvic anteversion after corrective spine surgery. We describe a rare case experiencing repeated posterior THA dislocation that occurred at 5 months after corrective spinal long fusion with pelvic fixation. A 64-year-old woman had undergone bilateral THA at 13 years before presenting to our institution. She had been diagnosed with kyphoscoliosis and underwent three subsequent spinal surgeries after the THA. We finally performed spinal corrective long fusion from T5 to ilium with pelvic fixation (with iliac screws). Five months later, she experienced severe hip pain when she tried to stand up from the toilet, and was unable to move, due to posterior THA dislocation. Therefore, we performed closed reduction under sedation, and her left hip was easily reduced. After the reduction, she started to walk with a hip abduction brace. However, she had experienced 5 subsequent dislocations. Based on our findings and previous reports, we have hypothesized that posterior dislocation could be occurred after spinal corrective long fusion with pelvic fixation due to three mechanisms: (1) a change in the THA cup alignment before and after spinal corrective long fusion surgery, (2) decreased and fixed pelvic posterior tilt in the sitting position, or (3) the trunk's forward tilting during standing-up motion after spinopelvic fixation. Spinal long fusion with pelvic fixation could be a risk factor for posterior THA dislocation.
Callaghan, John J; O'Rourke, Michael R; Goetz, Devon D; Lewallen, David G; Johnston, Richard C; Capello, William N
2004-12-01
Constrained acetabular components have been used to treat certain cases of intraoperative instability and postoperative dislocation after total hip arthroplasty. We report our experience with a tripolar constrained component used in these situations since 1988. The outcomes of the cases where this component was used were analyzed for component failure, component loosening, and osteolysis. At average 10-year followup, for cases treated for intraoperative instability (2 cases) or postoperative dislocation (4 cases), the component failure rate was 6% (6 of 101 hips in 5 patients). For cases where the constrained liner was cemented into a fixed cementless acetabular shell, the failure rate was 7% (2 of 31 hips in 2 patients) at 3.9-year average followup. Use of a constrained liner was not associated with an increased osteolysis or aseptic loosening rate. This tripolar constrained acetabular liner provided total hip arthroplasty construct stability in most cases in which it was used for intraoperative instability or postoperative dislocation.
Surgical hip dislocation for treatment of cam femoroacetabular impingement
Chaudhary, Milind M; Chaudhary, Ishani M; Vikas, KN; KoKo, Aung; Zaw, Than; Siddhartha, A
2015-01-01
Background: Cam femoroacetabular impingement is caused by a misshapen femoral head with a reduced head neck offset, commonly in the anterolateral quadrant. Friction in flexion, adduction and internal rotation causes limitation of the hip movements and pain progressively leading to labral and chondral damage and osteoarthritis. Surgical hip dislocation described by Ganz permits full exposure of the hip without damaging its blood supply. An osteochondroplasty removes the bump at the femoral head neck junction to recreate the offset for impingement free movement. Materials and Methods: Sixteen patients underwent surgery with surgical hip dislocation for the treatment of cam femoroacetabular impingement by open osteochondroplasty over last 6 years. Eight patients suffered from sequelae of avascular necrosis (AVN). Three had a painful dysplastic hip. Two had sequelae of Perthes disease. Three had combined cam and pincer impingement caused by retroversion of acetabulum. All patients were operated by the trochanteric flip osteotomy with attachments of gluteus medius and vastus lateralis, dissection was between the piriformis and gluteus minimus preserving the external rotators. Z-shaped capsular incision and dislocation of the hip was done in external rotation. Three cases also had subtrochanteric osteotomy. Two cases of AVN also had an intraarticular femoral head reshaping osteotomy. Results: Goals of treatment were achieved in all patients. No AVN was detected after a 6 month followup. There were no trochanteric nonunions. Hip range of motion improved in all and Harris hip score improved significantly in 15 of 16 cases. Mean alpha angle reduced from 86.13° (range 66°–108°) to 46.35° (range 39°–58°). Conclusion: Cam femoroacetabular Impingement causing pain and limitation of hip movements was treated by open osteochondroplasty after surgical hip dislocation. This reduced pain, improved hip motion and gave good to excellent results in the short term. PMID:26538754
Gluteal tendinopathy and hip osteoarthritis: Different pathologies, different hip biomechanics.
Allison, Kim; Hall, Michelle; Hodges, Paul W; Wrigley, Tim V; Vicenzino, Bill; Pua, Yong-Hao; Metcalf, Ben; Grimaldi, Alison; Bennell, Kim L
2018-03-01
Gluteal tendinopathy (GT) and hip osteoarthritis (OA) are the most common causes of hip pain and associated disability in older adults. Pain and altered walking biomechanics are common to both conditions. This study aimed to compare three-dimensional walking biomechanics between individuals with unilateral, symptomatic GT and HOA. Sixty individuals with symptomatic unilateral GT confirmed by magnetic-resonance-imaging and 73 individuals with symptomatic unilateral HOA (Kellgren-Lawrence Grade ≥ 2) underwent three-dimensional gait analysis. Maximum and minimum values of the external sagittal hip moment, the first peak, second peak and mid-stance minimum of the hip adduction moment (HAM), sagittal plane hip excursion and hip joint angles, pelvic obliquity and trunk lean, at the three HAM time points during stance phase of walking were compared between groups. Compared to individuals with HOA, those with GT exhibited a greater hip peak extension moment (P < 0.001) and greater HAM throughout the stance phase of walking (P = 0.01-P < 0.001), greater hip adduction (P < 0.001) and internal rotation (P < 0.01-P < 0.001) angles and lower hip flexion angles and excursion (P = 0.02 - P < 0.001). Individuals with HOA exhibited a greater forward trunk lean (P ≤ 0.001) throughout stance, and greater ipsilateral trunk lean in the frontal plane (P < 0.001) than those with GT. Despite presence of pain in both conditions, hip kinematics and kinetics differ between individuals with symptomatic unilateral GT and those with symptomatic unilateral HOA. These condition-specific impairments may be targets for optimization of management of HOA and GT. Copyright © 2018 Elsevier B.V. All rights reserved.
... or a blow, sometimes from playing a contact sport. You can dislocate your ankles, knees, shoulders, hips, ... to dislocate it again. Wearing protective gear during sports may help prevent dislocations.
Hip dislocations and concurrent injuries in motor vehicle collisions.
Cooper, Joseph; Tilan, Justin; Rounds, Alexis D; Rosario, Santano; Inaba, Kenji; Marecek, Geoffrey S
2018-04-27
Motor Vehicle Collisions (MVC) can cause high energy hip dislocations associated with serious injury profiles impacting triage. Changes in safety and regulation of restraint devices have likely lowered serious injuries from what was previously reported in the 1990s. This study aims to describe modern-day injury profile of patients with traumatic hip dislocations, with special attention to aortic injury. Retrospective review of a prospectively maintained trauma database at an urban level 1 trauma center was conducted. Patients with hip dislocation following MVC between January 2005 and December 2015 were grouped based on seatbelt use and airbag deployment. Patients with unknown restraint use were excluded. Multiple logistic regression was used to identify risk of injury profile between groups. Of 204 patients with hip dislocation after MVC, nearly 57% were unrestrained. Seatbelt alone was used in 36 (17.7%), airbag deployed in 14 (6.9%), and 38 (18.6%) with both. Gender and number of injuries were similar between groups. The most common concomitant injury was acetabular fracture (53.92%) and the abdominopelvic region was the most injured. Use of a seatbelt with airbag deployment was protective of concomitant pelvic ring injury (OR = 0.22). Airbag deployment was significantly protective of lumbar fracture (OR = 0.15) while increasing the likelihood of radial and ulnar fracture or dislocation (OR = 3.27), acetabular fracture (OR = 5.19), and abdominopelvic injury (OR = 5.07). The no restraint group had one patient (0.80%) with an intimal tear of the thoracic aorta identified on CT chest that was successfully medically managed. Hip dislocations are high energy injuries with severe associated injuries despite upgrades in restraint devices. These patients require careful examination and heightened awareness when evaluating for concomitant injuries. Copyright © 2018 Elsevier Ltd. All rights reserved.
Youdas, James W; Hartman, James P; Murphy, Brooke A; Rundle, Ashley M; Ugorowski, Jenna M; Hollman, John H
2017-02-01
Hip extension strengthening exercises which maximize gluteus maximus contributions and minimize hamstring influences may be beneficial for persons with hip pain. This study's aim was to compare muscle activation of the gluteus maximus and hamstrings from healthy subjects during a supine resisted hip extension exercise versus supine unilateral bridge to neutral. Surface electromyographic (EMG) signals were obtained from the right gluteus maximus and hamstrings in 13 healthy male and 13 healthy female subjects. Maximum voluntary isometric contractions (MVICs) were collected to normalize data and permit meaningful comparisons across muscles. Peak median activation of the gluteus maximus was 33.8% MVIC for the bridge and 34.7% MVIC for the hip extension exercise, whereas peak median recruitment for hamstrings was 28.4% MVIC for the bridge and 51% MVIC for the hip extension exercise. The gluteus maximus to hamstrings ratio was compared between the two exercises using the Wilcoxon signed-ranks test (α = 0.05). The ratio (p = 0.014) was greater in the supine unilateral bridge (median = 111.3%) than supine hip extension exercise (median = 59.2%), suggesting a reduction of hamstring recruitment in the unilateral bridge to neutral compared to the supine resisted hip extension exercise. The supine hip extension exercise demonstrated higher EMG activity of hamstrings in comparison with supine unilateral bridge and, therefore, may be less appropriate in subjects who need to increase gluteus maximus activation.
Delaney, Ruth; Albright, Maurice; Rebello, Gleeson
2011-01-01
Retained intra-articular missiles from low-velocity handguns can lead to mechanical arthritis, synovitis, and lead toxicity. Various surgical approaches have been described to extract such foreign bodies from the hip joint. We present the case of a 17-year-old male in which the surgical dislocation approach was utilized to retrieve a bullet from the femoral head with a good short-term outcome. This case represents a rare application of the surgical hip dislocation approach for an unusual trauma. PMID:23198205
Steel, H H; Piston, R W; Clancy, M; Betz, R R
1993-02-01
An orthopaedic syndrome that apparently had not been reported previously was identified in twenty-three children. Characteristics shared by all twenty-three children included Hispanic descent, residence in Puerto Rico, bilateral dislocation of the hip, dislocated radial heads, short stature, and other osseous anomalies. Twelve dislocated hips in six patients were not treated. All of these hips were functioning satisfactorily at the time of the review, but only four of the children had reached skeletal maturity. Sixteen hips in eight patients remained reduced after closed reduction. Of these eight patients, the four who were skeletally immature at the time of the review had a satisfactory result, and the four who were skeletally mature had an unsatisfactory result because of discomfort or fibrous ankylosis. Eighteen hips in nine patients were treated with a reduction augmented by some form of operation. All of these hips redislocated. Of the forty-six elbows in the twenty-three children, thirty-three were dislocated, as seen clinically and radiographically; eight were normal, both clinically and radiographically; and there was dysplasia at the radiocapitellar articulation of the remaining five. Twenty of the twenty-three children were found to have carpal coalitions. Fourteen children had scoliosis, and five of them were managed with spinal arthrodesis and correction. Three patients had an anomaly of the cervical spine, with one deformity causing symptoms and signs that were treated with decompression. Eight patients had talipes cavus bilaterally, which was not treated.
Kempthorne, Joshua T; Armour, Paul C; Rietveld, John A; Hooper, Gary J
2011-06-01
Surgical dislocation of the hip has been developed to deal with the problems causing femoroacetabular impingement (FAI). This is a relatively recent procedure that was historically reserved for larger areas specializing in hip surgery. We hypothesized that surgical dislocation can be used for symptomatic FAI in a typical Australasian tertiary orthopaedic centre with acceptable results. This prospective study reviews the results of 53 surgical dislocations in this setting, looking particularly at functional outcomes and early complications. There were significant improvements in the Western Ontario and McMaster University Osteoarthritis Index score at 1, 2, 3 and 4 years post-operatively. Western Ontario and McMaster University Osteoarthritis Index scores increased by 23, 28, 34 and 35 points, respectively (P 0.0039). There was no significant improvement in hip range of motion. There were two (4%) early failures with conversion to total hip arthroplasty, and no cases of post-operative avascular necrosis of the femoral head. We believe that as the diagnosis of FAI and conservative nonarthroplasty surgery of the hip gains wider acceptance, it will become a procedure that should be offered to all appropriate patients in an attempt to delay or limit total hip arthroplasty in this young age group.
Li, Lianhua; Ren, Jixin; Liu, Jia; Wang, Hao; Sang, Qinghua; Liu, Zhi; Sun, Tiansheng
2016-12-01
Hip dislocation after treatment of a femoral neck fracture with a hemiarthroplasty remains an important problem in the treatment of hip fractures, but the associations between patient factors and surgical factors, and how these factors contribute to dislocation in patients who have undergone bipolar hemiarthroplasty through an anterolateral approach for femoral neck fracture currently are only poorly characterized. We evaluated patients with bipolar hemiarthroplasty dislocation after surgery for femoral neck fracture treated through an anterolateral approach and asked: (1) What are the frequency, characteristics, and risk factors of bipolar hemiarthroplasty dislocations? (2) What are the frequency, characteristics, and risk factors of bipolar hemiarthroplasty dissociations? A review of hospital records for patients who underwent bipolar hip hemiarthroplasty for femoral neck fracture at one hospital between July 2004 and August 2014 was conducted. During that time, 1428 patients were admitted with a diagnosis of femoral neck fracture; 508 of these patients underwent bipolar hip hemiarthroplasty, of whom 61 died and 23 were lost to followup during the first year, leaving 424 (83%) available for analysis. The remainder of the patients during that time were treated with internal fixation (512), unipoloar hip arthroplasty (17), or THA (391). For each patient with dislocation, we selected five control patients from the cohort according to sex, age (± 3 years), and year of entry in the study to eliminate some confounding factors. We recorded patient characteristics regarding demographics, medical comorbidities, Katz score, American Society of Anesthesiologists score, Mini-Mental State Examination (MMSE) score, and anesthesia type. Medical comorbidities included diabetes, chronic pulmonary disease, heart disease, neuromuscular diseases, and dementia. Univariate analyses were used to search for possible risk factors. Conditional logistic regression analyses on dislocation or dissociation were performed to estimate hazard rates (HRs) and corresponding 95% CIs with covariates of a probability less than 0.1 in univariate analysis. In this cohort, there were 26 dislocations including four that were also dissociations. The proportion of patients experiencing a dislocation was 6% (26 of 424). The mean interval from surgery to dislocation was 56 weeks (range, 0-433 weeks), and 18 dislocations (69%) occurred within 3 months after surgery. Three variables were independently associated with an increased risk of hip dislocation: dementia (HR, 3.51; 95% CI, 1.19-10.38; p = 0.02), discrepancy of offset (HR, 1.72; 95% CI, 1.15-2.58; p = 0.008), and lower MMSE score (HR, 0.93; 95% CI, 0.88-0.98; p = 0.007). The proportion of patients experiencing a dissociation was 0.9% (four of 424). The result of conditional logistic regression for dissociation showed that cup size smaller than 43 mm was the risk factor (HR = 513.05). However, there was no statistical difference with the probability equaling 0.47. After the anterolateral approach for treatment of femoral neck fracture using bipolar hemiarthroplasty, 6% of hips dislocated and 0.9% experienced dissociation. Cognitive dysfunction and discrepancy of offset were independent risk factors associated with an increased risk of prosthetic dislocation. The small cup without a safety ring may be the risk factor of dissociation. Discrepancy of offset should be avoided during the operation by performing an accurate femoral osteotomy and choosing an adequate femoral stem neck length. For patients with cognitive dysfunction and a small cup, suturing the joint capsule during the operation and reinforcing protective measures after surgery might reduce the occurrence of dislocation and dissociation, however a study addressing this is necessary to confirm this. Level III, therapeutic study.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Butler, W; Merrick, G; Kurko, B
Purpose: To quantify the effect of metal hip prosthesis on the ability to track and localize electromagnetic transponders. Methods: Three Calypso transponders were implanted into two prostate phantoms. The geometric center of the transponders were identified on computed tomography and set as the isocenter. With the phantom stationary on the treatment table and the tracking array 14-cm above the isocenter, data was acquired by the Calypso system at 10 Hz to establish the uncertainty in measurements. Transponder positional data was acquired with unilateral hip prostheses of different metallic compositions and then with bilateral hips placed at variable separation from themore » phantom. Results: Regardless of hip prosthesis composition, the average vector displacement in the presence of a unilateral prosthesis was < 0.5 mm. The greatest contribution to overall vector displacement occurred in the lateral dimension. With bilateral hip prosthesis, the average vector displacement was 0.3 mm. The displacement in the lateral dimension was markedly reduced compared with a unilateral hip, suggesting that there was a countervailing effect with bilateral hip prosthesis. The greatest average vector displacement was 0.6 mm and occurred when bilateral hip prostheses were placed within 4 cm of the detector array. Conclusion: Unilateral and bilateral hip prostheses did not have any meaningful effect on the ability to accurately track electromagnetic transponders implanted in a prostate phantom. At clinically realistic distances between the hip and detection array, the average tracking error is negligible.« less
Yeung, Marco; Memon, Muzammil; Simunovic, Nicole; Belzile, Etienne; Philippon, Marc J; Ayeni, Olufemi R
2016-06-01
Gross hip instability is a rare complication after hip arthroscopy, and there is limited literature surrounding this topic. This systematic review investigates cases of gross hip instability after arthroscopy and discusses the risk factors associated with this complication. A systematic search was performed in duplicate for studies investigating gross hip instability after hip arthroscopy up to October 2015. Study parameters including sample size, mechanism and type of dislocation, surgical procedure details, patient characteristics, postoperative rehabilitation protocol, and level of evidence were analyzed. The systematic review identified 9 case reports investigating gross hip instability after hip arthroscopy (10 patients). Anterior dislocation occurred in 66.7% of patients, and most injuries occurred with a low-energy mechanism. Common surgical factors cited included unrepaired capsulotomy (77.8%) and iliopsoas release (33.3%), whereas patient factors included female gender (77.8%), acetabular dysplasia (22.2%), and general ligamentous laxity (11.1%). Postoperative restrictions and protocols were variable and inconsistently reported, and their relation to post-arthroscopy instability was difficult to ascertain. This systematic review discussed various patient, surgical, and postoperative risk factors of gross hip instability after arthroscopy. Patient characteristics such as female gender, hip dysplasia, and ligamentous laxity may be risk factors for post-arthroscopy dislocation. Similarly, surgical risk factors for iatrogenic hip instability may include unrepaired capsulotomies and iliopsoas debridement, although the role of capsular closure in iatrogenic instability is not clear. The influences of postoperative restrictions and protocols on dislocation are also unclear in the current literature. Surgeons should be cognizant of these risk factors when performing hip arthroscopy and be mindful that these factors appear to occur in combination. Level IV, systematic review of Level IV studies. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Patient Needs for an Ambulant Dislocation Alert System Following Total Hip Arthroplasty.
Huis In't Veld, Rianne; Peters, Anil; Vollenbroek-Hutten, Miriam; Hermens, Hermie; van den Hoven, Carmen
2018-05-01
One of the major complications in total hip arthroplasty (THA) is dislocation of the prosthesis. To prevent early dislocation, patients are instructed with movement restrictions. The first goal in this development is to obtain insight in the movement restrictions that are reported to have low levels of self-efficacy during activities of daily life. The second goal is to reveal the design needs for an ambulant hip dislocation alert system (HipDas) and the third goal is to explore its usability among patients. Patient-centered experiences with THA were explored by the use of a questionnaire and a semistructured focus group. The questionnaire was administered among n = 32 THA patients at 1 week preoperative and at 3 and 6 weeks postoperative. The questions addressed self-efficacy, performance and effort expectancy, and usefulness and social influence. The focus group consisted of patient journeys and scenario composition. The usability of a prototype version of the HipDas system was evaluated (n = 5). Flexion of the hip >90°, bending over while sitting in a chair, and sleeping in a supine position are the restrictions that have the lowest self-efficacy. The majority of patients (>86.6%) believe that a future HipDas is useful. Focus group outcomes suggest there is a gradual decrease in the threshold for feedback. The system is preferably used in the first 6 weeks after surgery and appeared to be usable and highly clinically relevant. HipDas is considered an interesting concept that can accelerate functional recovery of patients following THA by providing support on how to properly apply postoperative movement restrictions to prevent a dislocation.
Wang, X Q; Wu, C S; Sun, S; Wang, J; Li, W; Zhang, W
2018-04-01
Objective: To investigate the situation of hip dislocation with the application of "femur first" principle and "combined anteversion technique" during total hip arthroplasty. Methods: A retrospective analysis has been done on the clinical data about 104 patients(133 hips)who were diagnosed as hip disease and were treated with total hip arthroplasty by the doctors from the Department of Joint Orthorpaedics of Shandong Provincial Hospital Affiliated to Shandong University from June 2014 to June 2016, and all the prostheses applied in the operation were cementless ones.Among them, 65 patients were males, 39 females and their age was 46.6 years (ranging from 23 to 76 years) .And 29 of them underwent bilateral hip operations and 75 unilateral ones.Seventy-six cases of aseptic necrosis of the femoral head in the terminal stage, 28 cases of hip dysplasia and osteoarthritis.Surgical approach: of all the operations, 103 hips were operated on with hardinge approach, 30 with posterolateral approach.During the operation, first of all, the femoral medullary cavity was broached and then the anteversion of intramedullary broacher was measured.After that, the anteversion of the acetabular cup was calculated as 37° minus the anteversion of the broacher, and the acetabular cup was implanted at that angle.The patients' prosthesis combined anteversion, range of motion of the hip joint, operation time, hemorrhage amount, and complications had been kept record.One, three, and six months respectively after the operation, all the patients received outpatient review, and took anteroposterior and lateral position X-ray examination.Harris hip score had been applied to evaluate their hip function before the operation and six months after the operation. Results: All the patients had been operated on smoothly, with the operation time of(57.6±14.5)minutes(36-115 minutes)and hemorrhage amount of (336.5±50.8)ml(180-620 ml). The operation finding showed that the combined anteversion by employing"femur first"principle and combined anteversion techniqueis was (36.6±6.8)°. Also, range of motion of the patients' hip conforms to the D'Lima criterion and no patients had experienced dislocation and some other serious complications.The follow-up ended at August 2017, which lasted for 12.2 months(6-18 months), and 88 cases(119 hips) were interviewed. The Harris hip score for the affected sides of the hip joints 6 months after the surgery was 94.6(86-100). Compared with the score of 29.8(12-43) before surgery, the t -test had proven its statistical significance( t =12.82, P =0.003). Conclusion: Based upon the "femoral first" principle and "combined anteversion technique" during total hip arthroplasty, these operations has been carried out well enough to meet the patients' needs of performing normal daily activities.
Li, Junyan; McWilliams, Anthony B; Jin, Zhongmin; Fisher, John; Stone, Martin H; Redmond, Anthony C; Stewart, Todd D
2015-06-01
Symptomatic leg length inequality accounts for 8.7% of total hip replacement related claims made against the UK National Health Service Litigation authority. It has not been established whether symptomatic leg length inequality patients following total hip replacement have abnormal hip kinetics during gait. Hip kinetics in 15 unilateral total hip replacement patients with symptomatic leg length inequality during gait was determined through multibody dynamics and compared to 15 native hip healthy controls and 15 'successful' asymptomatic unilateral total hip replacement patients. More significant differences from normal were found in symptomatic leg length inequality patients than in asymptomatic total hip replacement patients. The leg length inequality patients had altered functions defined by lower gait velocity, reduced stride length, reduced ground reaction force, decreased hip range of motion, reduced hip moment and less dynamic hip force with a 24% lower heel-strike peak, 66% higher mid-stance trough and 37% lower toe-off peak. Greater asymmetry in hip contact force was also observed in leg length inequality patients. These gait adaptions may affect the function of the implant and other healthy joints in symptomatic leg length inequality patients. This study provides important information for the musculoskeletal function and rehabilitation of symptomatic leg length inequality patients. Copyright © 2015. Published by Elsevier Ltd.
McCurdy, Kevin; Walker, John; Armstrong, Rusty; Langford, George
2014-09-01
The purpose of this study was to compare the relationship between several measures of single-joint, isometric, eccentric, and squat strength and unilateral and bilateral landing mechanics at the hip and knee in women. Twenty six healthy female subjects with previous athletic experience (height, 165.1 ± 7.01 cm; mass, 60.91 ± 7.14 kg; age, 20.9 ± 1.62 years) participated in this study. Hip and knee mechanics were measured using the MotionMonitor capture system (Innovative Sports Training, Inc.) with 3-dimensional electromagnetic sensors during bilateral (60 cm) and unilateral drop jumps (30 cm). On a separate day, isometric hip extension, external rotation, and abduction strength (lbs) were measured using a handheld dynamometer (Hoggan Health Industries, Inc.). Eccentric and isometric knee strength were measured on the Biodex IV Isokinetic Dynamometer (Biodex Medical Systems, Inc.). Free weight was used to measure the bilateral squat and a modified single-leg squat. The strongest correlations were found between squat strength and knee valgus (-0.77 ≤ r ≤ -0.83) and hip adduction (-0.5 ≤ r ≤ -0.65). After controlling for squat strength, hip external rotation strength and unilateral knee valgus (-0.41), hip abduction strength and bilateral knee valgus (-0.43), and knee flexion strength and bilateral hip adduction (-0.57) remained significant. Eccentric knee flexion strength and unilateral knee internal rotation was the only significant correlation for eccentric strength (-0.40). Squat strength seems to be the best predictor of knee valgus and was consistently related to hip adduction. Isometric and eccentric measures demonstrated few significant correlations with hip and knee excursion while demonstrating a low-to-moderate relationship. Hip and knee flexion and rotation do not seem to be related to strength. Squat strength should receive consideration during risk assessment for noncontact knee injury.
Can we prevent hip dislocation in children with cerebral palsy? Effects of postural management.
Picciolini, Odoardo; LE Métayer, Michel; Consonni, Dario; Cozzaglio, Massimo; Porro, Matteo; Gasparroni, Verusca; Panou, Artemisia; Mosca, Fabio; Portinaro, Nicola M
2016-10-01
Hip dislocation is common in children with cerebral palsy (CP). At birth they do not have musculoskeletal deformities but they develop over time due to the combined effects of the movement disorder and impaired gross motor function. Early detection and treatment of a hip at risk is needed to modify the natural of hip development in CP. The aim of this study was to determine the effect of postural management treatment on hip displacement's progression in children CP. Prospective comparative non-randomized study. Rehabilitative outpatient unit. Fifty-one children with CP were studied; the treated group (N.=30) was compared to a control group (N.=21). The treated group followed a two year's long combined treatment program consisting a neurodevelopment treatment (NDT) two times a week and a 5 hours daily siège moulé postural program. The control group underwent only NDT twice a week for two years. Hip radiographs were measured with the migration percentage (MP) method at baseline, at 1 and 2 years of follow-up. A significant difference has been observed in the MP (%) trend (P<0.001) between treatment and control groups. At 2 years, there was a marked worsening (MP from 23.0 to 37.7) in the control group, compared to the stability (from 28.8 to 26.8) in the treatment group. This study supports the evidence that conservative postural management of hip deformity is useful to prevent the natural progression of hip dislocation. Hip radiographic follow up program together with NDT and postural management program is useful to modify the natural progression of hip dislocation in children with CP.
[The hip joint in neuromuscular disorders].
Strobl, W M
2009-07-01
Physiologic motor and biomechanical parameters are prerequisites for normal hip development and hip function. Disorders of muscle activity and lack of weight bearing due to neuromuscular diseases may cause clinical symptoms such as an unstable hip or reduced range of motion. Disability and handicap because of pain, hip dislocation, osteoarthritis, gait disorders, or problems in seating and positioning are dependent on the severity of the disease, the time of occurrence, and the means of prevention and treatment. Preservation of pain-free and stable hip joints should be gained by balancing muscular forces and by preventing progressive dislocation. Most important is the exact indication of therapeutic options such as movement and standing therapy as well as drugs and surgery.
Lampropulos, Mario; Puigdevall, Miguel H; Zapozko, Daniel; Malvárez, Héctor R
2008-01-01
We describe the results obtained with an alternative method of treatment for spastic painful hip dislocations in nonambulatory patients, which consists of a proximal femoral resection with capsular interposition arthroplasty, and the addition of a hinged external fixator for postoperative articulated hip distraction to allow for an immediate upright position and the ability to sit in a wheelchair. We performed this technique in three patients (four hips) with a mean age at the time of surgery of 15 years. Postoperatively, clinical improvement was observed in all four hips, with respect to pain relief, sitting tolerance, perineal care and functional range of motion.
Bouchet, R; Mercier, N; Saragaglia, D
2011-02-01
Dislocation is a frequent complication of total hip arthroplasties (THA) especially in older patients, especially when using a posterior approach. In these cases, dual mobility (DM) cups developed by Gilles Bousquet in 1975 can be indicated to reduce this complication risk. Dual mobility cups reduce the rate of dislocation in primary total hip arthroplasty using posterior approach in a single-surgeon series. Test this hypothesis in a controlled study to compare the rate of dislocation in primary total hip arthroplasties done in patients over 50 years old either with a dual mobility cup or a conventional metal-on-polyethylene 28-mm diameter head. Two consecutive series of primary total hip replacements were performed by a single surgeon using a posterolateral approach. The piriformis tendon was left intact. The DM series included 105 patients who underwent arthroplasty between January 2005 and June 2007 with a dual mobility cup (60 women and 45 men, mean age 76.6±5.65 years old [53-93]). The control series (S series) included 108 patients who underwent arthroplasty (56 women and 52 men, mean age 74.2±5.9 years old [53-87]) with a conventional 28-mm polyethylene cup between January 2003 and June 2005. All hip replacements included a 28-mm metal-polyethylene cup and a 12-14-mm Morse taper. Both groups were comparable for gender, diagnosis, body mass index, type of anesthesia and ASA score distribution. All patients included in this series had a minimum follow-up of 1 year. There were no dislocations in the DM series and five early dislocations (before the third month) in the S series for a rate of 4.63%. Although the rate of dislocation was higher in the S series (4.63% vs 0%), the difference was barely significant (P=0.0597). This study comparing the incidence of dislocations after THA with conventional or dual mobility cups, shows that even using a posterior approach and in older patients, dual mobility cups increase stability with no postoperative dislocations. Although results are barely significant, a larger series should confirm the benefit of this implant. In this series, morbidity was not increased with dual mobility cups. Level III: retrospective case-control study. Copyright © 2010 Elsevier Masson SAS. All rights reserved.
21 CFR 890.3665 - Congenital hip dislocation abduction splint.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Congenital hip dislocation abduction splint. 890.3665 Section 890.3665 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890...
21 CFR 890.3665 - Congenital hip dislocation abduction splint.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Congenital hip dislocation abduction splint. 890.3665 Section 890.3665 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890...
21 CFR 890.3665 - Congenital hip dislocation abduction splint.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Congenital hip dislocation abduction splint. 890.3665 Section 890.3665 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890...
21 CFR 890.3665 - Congenital hip dislocation abduction splint.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Congenital hip dislocation abduction splint. 890.3665 Section 890.3665 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890...
Chotai, Pranit N; Ebraheim, Nabil A; Hart, Ryan; Wassef, Andrew
2015-11-05
Constellation of ipsilateral posterior hip dislocation, intertrochanteric- and proximal tibial fracture with popliteal artery injury is rare. Management of this presentation is challenging. A motor vehicle accident victim presented with these injuries, but without any initial signs of vascular compromise. Popliteal artery injury was diagnosed intra-operatively and repaired. This was followed by external fixation of tibial fracture, open reduction of dislocated hip and internal fixation of intertrochanteric fracture. Patient regained bilateral complete weight bearing and returned to pre-accident activity level. Apt surgical management including early repair of vascular injury in such a trauma mélange allows for a positive postoperative outcome.
Acetabular cup position and risk of dislocation in primary total hip arthroplasty.
Seagrave, Kurt G; Troelsen, Anders; Malchau, Henrik; Husted, Henrik; Gromov, Kirill
2017-02-01
Background and purpose - Hip dislocation is one of the most common complications following total hip arthroplasty (THA). Several factors that affect dislocation have been identified, including acetabular cup positioning. Optimal values for cup inclination and anteversion are debatable. We performed a systematic review to describe the different methods for measuring cup placement, target zones for cup positioning, and the association between cup positioning and dislocation following primary THA. Methods - A systematic search of literature in the PubMed database was performed (January and February 2016) to identify articles that compared acetabular cup positioning and the risk of dislocation. Surgical approach and methods for measurement of cup angles were also considered. Results - 28 articles were determined to be relevant to our research question. Some articles demonstrated that cup positioning influenced postoperative dislocation whereas others did not. The majority of articles could not identify a statistically significant difference between dislocating and non-dislocating THA with regard to mean angles of cup anteversion and inclination. Most of the articles that assessed cup placement within the Lewinnek safe zone did not show a statistically significant reduction in dislocation rate. Alternative target ranges have been proposed by several authors. Interpretation - The Lewinnek safe zone could not be justified. It is difficult to draw broad conclusions regarding a definitive target zone for cup positioning in THA, due to variability between studies and the likely multifactorial nature of THA dislocation. Future studies comparing cup positioning and dislocation rate should investigate surgical approach separately. Standardized tools for measurement of cup positioning should be implemented to allow comparison between studies.
Acetabular cup position and risk of dislocation in primary total hip arthroplasty
Seagrave, Kurt G; Troelsen, Anders; Malchau, Henrik; Husted, Henrik; Gromov, Kirill
2017-01-01
Background and purpose — Hip dislocation is one of the most common complications following total hip arthroplasty (THA). Several factors that affect dislocation have been identified, including acetabular cup positioning. Optimal values for cup inclination and anteversion are debatable. We performed a systematic review to describe the different methods for measuring cup placement, target zones for cup positioning, and the association between cup positioning and dislocation following primary THA. Methods — A systematic search of literature in the PubMed database was performed (January and February 2016) to identify articles that compared acetabular cup positioning and the risk of dislocation. Surgical approach and methods for measurement of cup angles were also considered. Results— 28 articles were determined to be relevant to our research question. Some articles demonstrated that cup positioning influenced postoperative dislocation whereas others did not. The majority of articles could not identify a statistically significant difference between dislocating and non-dislocating THA with regard to mean angles of cup anteversion and inclination. Most of the articles that assessed cup placement within the Lewinnek safe zone did not show a statistically significant reduction in dislocation rate. Alternative target ranges have been proposed by several authors. Interpretation— The Lewinnek safe zone could not be justified. It is difficult to draw broad conclusions regarding a definitive target zone for cup positioning in THA, due to variability between studies and the likely multifactorial nature of THA dislocation. Future studies comparing cup positioning and dislocation rate should investigate surgical approach separately. Standardized tools for measurement of cup positioning should be implemented to allow comparison between studies. PMID:27879150
Dan, Michael; Phillips, Alfred; Simonian, Marcus; Flannagan, Scott
2015-06-01
We provide a review of literature on reduction techniques for posterior hip dislocations and present our experience with a novel technique for the reduction of acute posterior hip dislocations in the ED, 'the rocket launcher' technique. We present our results with six patients with prosthetic posterior hip dislocation treated in our rural ED. We recorded patient demographics. The technique involves placing the patient's knee over the shoulder, and holding the lower leg like a 'Rocket Launcher' allow the physician's shoulder to work as a fulcrum, in an ergonomically friendly manner for the reducer. We used Fisher's t-test for cohort analysis between reduction techniques. Of our patients, the mean age was 74 years (range 66 to 85 years). We had a 83% success rate. The one patient who the 'rocket launcher' failed in, was a hemi-arthroplasty patient who also failed all other closed techniques and needed open reduction. When compared with Allis (62% success rate), Whistler (60% success rate) and Captain Morgan (92% success rate) techniques, there was no statistically significant difference in the successfulness of the reduction techniques. There were no neurovascular or periprosthetic complications. We have described a reduction technique for posterior hip dislocations. Placing the patient's knee over the shoulder, and holding the lower leg like a 'Rocket Launcher' allow the physician's shoulder to work as a fulcrum, thus mechanically and ergonomically superior to standard techniques. © 2015 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.
Mayer, Stephanie W; Abdo, João Caetano Munhoz; Hill, Mary K; Kestel, Lauryn A; Pan, Zhaoxing; Novais, Eduardo N
2016-09-01
Femoroacetabular impingement (FAI) deformity has been associated with posterior hip instability in adult athletes. To determine if FAI deformity is associated with posterior hip instability in adolescents, the femoral head-neck junction or acetabular structure in a cohort of adolescent patients who sustained a low-energy, sports-related posterior hip dislocation was compared with that in a group of healthy age- and sex-matched controls with no history of hip injury or pain. Cross-sectional study; Level of evidence, 3. We identified 12 male patients (mean age, 13.9 years; range, 12-16 years) who sustained a sports-related posterior hip dislocation and underwent a computed tomography (CT) scan after closed reduction. For each patient, 3 age- and sex-matched healthy controls were identified. Femoral head-neck type was assessed by measurement of the alpha angle on the radially oriented CT images at the 12-, 1-, 2-, and 3-o'clock positions. Age, body mass index (BMI), alpha angle at each position, acetabular version, Tönnis angle, and lateral center-edge angle (LCEA) on the involved hip in the dislocation group were compared with those of the matched controls using a mixed-effects model. A logistic regression analysis using a generalized estimating equation was used to compare the percentage of subjects with cam-type FAI deformity (alpha angle >55°) in each group. The dislocation and control groups were similar in age distribution and BMI (P > .05). The mean alpha angles were statistically significantly higher in the dislocation group compared with the control group at the superior (46.3° ± 1.1° vs 42.7° ± 0.6°; P = .0213), superior-anterior (55.5° ± 1.9° vs 46.0° ± 1.3°; P = .0005), and anterior-superior (54.9° ± 1.5° vs 48.9° ± 1.0°; P = .0045) regions. Cam deformity was present in a larger proportion of patients in the dislocation group than in the control group (P < .0035). An alpha angle greater than 55° was present in 16.7% of the dislocation group and 0% of the control group at the 12-o'clock position (P = .1213), 41.7% versus 0% at the 1-o'clock position (P = .0034), 58% versus 6% at the 2-o'clock position (P = .0004), and 25% versus 2.8% at the 3-o'clock position (P = .0929). Acetabular anteversion was lower in the dislocation group (9.6° ± 1.4°) compared with the control group (15.1° ± 0.8°) (P = .0068). Mean acetabular LCEA was within a normal range in both groups. A significantly higher mean alpha angle from the superior to the anterior-superior regions of the femoral head-neck junction and lower acetabular version were found in adolescents who sustained low-energy, sports-related posterior hip dislocations. © 2016 The Author(s).
Huayamave, Victor; Rose, Christopher; Serra, Sheila; Jones, Brendan; Divo, Eduardo; Moslehy, Faissal; Kassab, Alain J; Price, Charles T
2015-07-16
A physics-based computational model of neonatal Developmental Dysplasia of the Hip (DDH) following treatment with the Pavlik Harness (PV) was developed to obtain muscle force contribution in order to elucidate biomechanical factors influencing the reduction of dislocated hips. Clinical observation suggests that reduction occurs in deep sleep involving passive muscle action. Consequently, a set of five (5) adductor muscles were identified as mediators of reduction using the PV. A Fung/Hill-type model was used to characterize muscle response. Four grades (1-4) of dislocation were considered, with one (1) being a low subluxation and four (4) a severe dislocation. A three-dimensional model of the pelvis-femur lower limb of a representative 10 week-old female was generated based on CT-scans with the aid of anthropomorphic scaling of anatomical landmarks. The model was calibrated to achieve equilibrium at 90° flexion and 80° abduction. The hip was computationally dislocated according to the grade under investigation, the femur was restrained to move in an envelope consistent with PV restraints, and the dynamic response under passive muscle action and the effect of gravity was resolved. Model results with an anteversion angle of 50° show successful reduction Grades 1-3, while Grade 4 failed to reduce with the PV. These results are consistent with a previous study based on a simplified anatomically-consistent synthetic model and clinical reports of very low success of the PV for Grade 4. However our model indicated that it is possible to achieve reduction of Grade 4 dislocation by hyperflexion and the resultant external rotation. Copyright © 2015 Elsevier Ltd. All rights reserved.
Late septic hip dislocation with multifocal osteomyelitis and malaria: a case report.
Sreenivas, T; Menon, Jagdish; Nataraj, A R
2012-12-01
A 9-year-old boy presented with high-grade fever associated with pain and swelling in right hip and left leg of 1-week duration. Pus was found on diagnostic aspiration of the right hip joint. Emergency arthrotomy was performed through anterior approach with drill holes in proximal femur and culture showed MRSA. Intravenous antibiotics were given for 4 weeks. Patient symptomatically improved in immediate postoperative period and in bed hip mobilization was started. On eighth postoperative day, child developed high-grade intermittent fever with chills and rigors and diagnosed as plasmodium falciparum malaria. Fever subsided with antimalarial treatment. On twenty-first day, patient complained pain in right hip and X-ray showed posterior hip dislocation with osteomyelitis of proximal femur. Closed reduction and hip spica application was done under general anesthesia. At follow-up, the clinical result was fair with resolution of infection and stiff hip.
Koch, A; Jozwiak, M; Idzior, M; Molinska-Glura, M; Szulc, A
2015-02-01
We investigated the incidence and risk factors for the development of avascular necrosis (AVN) of the femoral head in the course of treatment of children with cerebral palsy (CP) and dislocation of the hip. All underwent open reduction, proximal femoral and Dega pelvic osteotomy. The inclusion criteria were: a predominantly spastic form of CP, dislocation of the hip (migration percentage, MP > 80%), Gross Motor Function Classification System, (GMFCS) grade IV to V, a primary surgical procedure and follow-up of > one year. There were 81 consecutive children (40 girls and 41 boys) in the study. Their mean age was nine years (3.5 to 13.8) and mean follow-up was 5.5 years (1.6 to 15.1). Radiological evaluation included measurement of the MP, the acetabular index (AI), the epiphyseal shaft angle (ESA) and the pelvic femoral angle (PFA). The presence and grade of AVN were assessed radiologically according to the Kruczynski classification. Signs of AVN (grades I to V) were seen in 79 hips (68.7%). A total of 23 hips (18%) were classified between grades III and V. Although open reduction of the hip combined with femoral and Dega osteotomy is an effective form of treatment for children with CP and dislocation of the hip, there were signs of avascular necrosis in about two-thirds of the children. There was a strong correlation between post-operative pain and the severity of the grade of AVN. ©2015 The British Editorial Society of Bone & Joint Surgery.
Scarborough, Donna Moxley; Linderman, Shannon; Berkson, Eric M.; Oh, Luke S.
2017-01-01
Objectives: Unilateral partial squat tasks are often used to assess athletes’ lower extremity (LE) neuromuscular control. Single squat biomechanics such as lateral drop of the non-stance limb’s pelvis have been linked to knee injury risk. Yet, there are limited studies on the factors contributing to pelvic instability during the unilateral partial squat such as anatomical alignment of the knee and hip strength. The purpose of this study was 1) to assess the influence of leg dominance on pelvic drop among female athletes during the repeated unilateral partial squat activity and 2) to investigate the contributions that lower limb kinematics and hip strength have on pelvis drop. Methods: 42 female athletes (27= softball pitchers, 15=gymnasts, avg age=16.48 ± 2.54 years) underwent lower limb assessment. The quadriceps angle (Q angle) and the average of 3 trials for hip abduction and extension strength (handheld dynamometer measurements) were used for analyses. 3D biomechanical analysis of the repeated unilateral partial squat activity followed using a 20 motion capture camera system which created a 15 segment model of each subject. The subject stood on one leg at the lateral edge of a 17.78 cm box with hands placed on the hips and squatted so that the free hanging contralateral limb came as close to the ground without contact for 5 continuous repetitions. One trial for each limb was performed. Peak pelvic drop and ankle, knee and hip angles and torques (normalized by weight) at this time point were calculated using Visual 3D (C-Motion) biomechanical software. Paired T-test, Spearman correlations and multiple regression model statistical analyses were performed. Results: Peak pelvic drop during the unilateral partial squat did not differ significantly on the basis of limb dominance (p=0.831, Dom: -3.40 ± 5.10° , ND: -3.46 ± 4.44°). Peak pelvic drop displayed a Spearman correlation with the functional measure of hip abduction/adduction (ABD/ADD) angle (rs= 0.627, p< 0.001) (Figure 1). No association was noted between peak pelvic drop and anatomical measures of Q angle or isometric hip extension strength. A multiple regression was performed to predict pelvis drop angle from the following 6 variables: isometric hip ABD strength, hip ABD/ADD angle, hip internal/external rotation angle, ankle supination/pronation (S/P) angle, height and weight. These variables statistically predicted pelvis drop, F(6,73) = 17.848, p < .0005, R2 = 0.595. The strongest combined predictor variables for pelvic drop in the female athletes were hip abduction/ adduction angle and strength followed by subject’s weight and ankle S/P angle (Table 1). Conclusion: Peak pelvic drop during the repeated unilateral partial squat activity did not correlate significantly with Q angle and hip extension strength. Instead, peak pelvic drop appears more related to a combination of biomechanical limb positioning, hip ABD strength and subject demographics. The regression model run on the repeated unilateral partial squat demonstrates predictive power of this dynamic assessment tool based on kinematic measures across multiple joints. Results could guide clinician screening for excessive pelvic drop in female athletes and based on the predictive model make recommendations for corrective conditioning to help prevent knee injury and guide return to sport following LE surgery. Table 1: Multivariate linear regression model for pelvic drop, Isometric hip strength and lower extremity kinematics during repeated partial squat activity among female athletes. Variable P Isometric hip abduction strength 0.034* Hip Abduction/Adduction Angle <0.001* Hip Internal/External Rotation Angle 0.936 Ankle Internal/External Rotation Angle 0.072 Height 0.398 Weight 0.011* * Level of significance established at p<0.05
Biomechanical analysis of cervical distraction.
Miller, L S; Cotler, H B; De Lucia, F A; Cotler, J M; Hume, E L
1987-11-01
A biomechanical analysis of cervical distraction is presented, and a model comparing closed reduction of cervical spine dislocations to spring mechanics is developed. Behavior of a spring may be described as F = k delta x where F = distraction force; delta x = elongation of the spring; and k = spring constant. The records and roentgenograms of 24 cervical spine dislocations were reviewed retrospectively. Evaluation of cervical distraction vs traction weight indicates that Ftraction = kneck delta x; where F = traction weight and x = distraction at the injured level. The constant, kneck, is different for bilateral and unilateral dislocations (P less than .001) and is a function of magnitude of injury and neck morphology. As determined in this study, traction weight needed for reduction of facet dislocations may be estimated using the formulae: Ftx = 107.1 lbs/cm (x) unilateral, and Ftx = 76.4 lbs/cm (x) bilateral.
Lessons learned from study of congenital hip disease in adults.
Hartofilakidis, George; Lampropoulou-Adamidou, Kalliopi
2016-12-18
Orthopaedic surgeons specialising in adult hip reconstruction surgery often face the problem of osteoarthritis secondary to congenital hip disease (CHD). To achieve better communication among physicians, better treatment planning and evaluation of the results of various treatment options, an agreed terminology is needed to describe the entire pathology. Furthermore, a generally accepted classification of the deformities is necessary. Herein, the authors propose the use of the term "congenital hip disease" and its classification as dysplasia, low dislocation and high dislocation. Knowledge of the CHD natural history facilitates comprehension of the potential development and progression of the disease, which differs among the aforementioned types. This can lead to better understanding of the anatomical abnormalities found in the different CHD types and thus facilitate preoperative planning and choice of the most appropriate management for adult patients. The basic principles for improved results of total hip replacement in patients with CHD, especially those with low and high dislocation, are: Wide exposure, restoration of the normal centre of rotation and the use of special techniques and implants for the reconstruction of the acetabulum and femur. Application of these principles during total hip replacement in young female patients born with severe deformities of the hip joint has led to radical improvement of their quality of life.
On the permanent hip-stabilizing effect of atmospheric pressure.
Prietzel, Torsten; Hammer, Niels; Schleifenbaum, Stefan; Kaßebaum, Eric; Farag, Mohamed; von Salis-Soglio, Georg
2014-08-22
Hip joint dislocations related to total hip arthroplasty (THA) are a common complication especially in the early postoperative course. The surgical approach, the alignment of the prosthetic components, the range of motion and the muscle tone are known factors influencing the risk of dislocation. A further factor that is discussed until today is atmospheric pressure which is not taken into account in the present THA concepts. The aim of this study was to investigate the impact of atmospheric pressure on hip joint stability. Five joint models (Ø 28-44 mm), consisting of THA components were hermetically sealed with a rubber capsule, filled with a defined amount of fluid and exposed to varying ambient pressure. Displacement and pressure sensors were used to record the extent of dislocation related to intraarticular and ambient pressure. In 200 experiments spontaneous dislocations of the different sized joint models were reliably observed once the ambient pressure was lower than 6.0 kPa. Increasing the ambient pressure above 6.0 kPa immediately and persistently reduced the joint models until the ambient pressure was lowered again. Displacement always exceeded half the diameter of the joint model and was independent of gravity effects. This experimental study gives strong evidence that the hip joint is permanently stabilized by atmospheric pressure, confirming the theories of Weber and Weber (1836). On basis of these findings the use of larger prosthetic heads, capsular repair and the deployment of an intracapsular Redon drain are proposed to substantially decrease the risk of dislocation after THA. Copyright © 2014 Elsevier Ltd. All rights reserved.
Usefulness of Arthroscopic Treatment of Painful Hip after Acetabular Fracture or Hip Dislocation.
Hwang, Jung-Taek; Lee, Woo-Yong; Kang, Chan; Hwang, Deuk-Soo; Kim, Dong-Yeol; Zheng, Long
2015-12-01
Painful hip following hip dislocation or acetabular fracture can be an important signal for early degeneration and progression to osteoarthritis due to intraarticular pathology. However, there is limited literature discussing the use of arthroscopy for the treatment of painful hip. The purpose of this retrospective study was to analyze the effectiveness and benefit of arthroscopic treatment for patients with a painful hip after major trauma. From July 2003 to February 2013, we reviewed 13 patients who underwent arthroscopic treatment after acetabular fracture or hip dislocation and were followed up for a minimum of 2 postoperative years. The degree of osteoarthritis based on the Tonnis classification pre- and postoperatively at final follow-up was determined. Clinical outcomes were evaluated using visual analogue scale for pain (VAS) and modified Harris hip score (MHHS), and range of motion (ROM) of the hip pre- and postoperatively at final follow-up. There were nine male and four female patients with a mean age at surgery of 28 years (range, 20 to 50 years). The mean follow-up period of the patients was 59.8 months (range, 24 to 115 months), and the mean interval between initial trauma and arthroscopic treatment was 40.8 months (range, 1 to 144 months). At the final follow-up, VAS and MHHS improved significantly from 6.3 and 53.4 to 3.0 and 88.3, respectively (p = 0.002 and p < 0.001, respectively). However, there were no significant differences in hip flexion, abduction, adduction, external rotation, and internal rotation as minor improvements from 113.1°, 38.5°, 28.5°, 36.5°, and 22.7° to 118.5°, 39.0°, 29.2°, 38.9°, and 26.5° were observed, respectively (p = 0.070, p = 0.414, p = 0.317, p = 0.084, and p = 0.136, respectively). None of the patients exhibited progression of osteoarthritis of the hip at the final follow-up. Arthroscopic treatment after acetabular fracture or hip dislocation is effective and delays the progression of traumatic osteoarthritis.
Mohammed, Riazuddin; Hayward, Keith; Mulay, Sanjay; Bindi, Frank; Wallace, Murray
2015-03-01
The concept of a dual-mobility hip socket involves the standard femoral head component encased in a larger polyethylene liner, which in turn articulates inside a metal shell implanted in the native acetabulum. The aim of this study was to assess outcomes from using a Serf Novae(®) Dual Mobility Acetabular cup (Orthodynamics Ltd, Gloucestershire, UK) to address the problem of instability in primary and revision total hip arthroplasty (THA). A retrospective review was carried out of all hip arthroplasties performed in a District General Hospital utilising the dual-mobility socket from January 2007 to December 2012. Clinical and radiological outcomes were analysed for 44 hips in 41 patients, comprising 20 primary and 24 revision THA. The average age of the study group was 70.8 years (range 56-84 years) for primary and 76.4 years (range 56-89 years) for revision arthroplasty. Among the primary THA, always performed for hip osteoarthritis or in presence of osteoarthritic changes, the reasons to choose a dual mobility cup were central nervous system problems such as Parkinson's disease, stroke, dementia (10), hip fracture (5), failed hip fracture fixation (2), severe fixed hip deformity (2) and diffuse peripheral neuropathy (1). The indications for revisions were recurrent dislocation (17), aseptic loosening with abductor deficiency (4), failed hemiarthroplasty with abductor deficiency (2) and neglected dislocation (1). At a mean follow-up of 22 months (range 6-63 months), none of the hips had any dislocation, instability or infection and no further surgical intervention was required. Radiological assessment showed that one uncemented socket in a revision arthroplasty performed for recurrent dislocation had changed position, but was stable in the new position. The patient did not have complications from this and did not need any surgical intervention. Even though postoperative hip stability depends on several factors other than design-related ones, our study shows promising early results for reducing the risk of instability in this challenging group of patients undergoing primary and revision hip arthroplasty. IV.
Miki, Hidenobu; Sugano, Nobuhiko; Hagio, Keisuke; Nishii, Takashi; Kawakami, Hideo; Kakimoto, Akihiro; Nakamura, Nobuo; Yoshikawa, Hideki
2004-04-01
In 17 patients with unilateral hip disease who underwent total hip arthroplasty (THA), the gait was analyzed preoperatively and 1, 3, 6, and 12 months after unilateral THA using a Vicon system to assess the recovery of walking speed and symmetrical movement of the hip, knee, ankle, and pelvis. The walking speed of these patients reached that of normal Japanese persons by 12 months after surgery. Walking speed was correlated with the range of hip motion on the operated side at 1 month postoperatively, and was correlated with the hip joint extension moment of force on both sides from 3 to 6 months after surgery. Before THA, asymmetry was observed in the range of the hip motion, maximum hip flexion, maximum hip extension, maximum knee flexion, as well as in pelvic obliquity, pelvic tilt, and pelvic rotation. There were no differences of the stride length or step length between both sides throughout the observation period. The preoperative range of hip flexion on the operated side during a gait cycle (21.3+/-7.9 degrees ) was significantly smaller than on the non-operated side (46.7+/-7.1 degrees ), and the difference between sides was still significant at 12 months after surgery (35.1+/-6.2 degrees on the operated side and 43.6+/-5.7 degrees on the non-operated side). The majority (74%) of the difference in hip motion range during this period was due to the difference in maximum extension of the hip. The increase in the range of pelvic tilt and the range of motion of the opposite hip showed an inverse correlation with the range of motion of the operated hip, suggesting a compensatory preoperative role. However, this correlation became insignificant after 6 months postoperatively. Asymmetry of the range of hip motion persisted at 12 months after THA in patients with unilateral coxoarthropathy during free level walking, while the operation normalized the spatial asymmetry of other joints and the walking speed prior to the recovery of hip motion.
Hoggett, L; Cross, C; Helm, T
2017-12-01
Dislocation after total hip arthroplasty (THA) remains a significant complication of the procedure and is the third leading cause for revision THA. One technique for treatment of this complication is the use of the posterior lip augmentation device (PLAD). We describe our experience using the PLAD including complication rates. A retrospective review of 55 PLADs (54 patients) was carried out following identification from electronic theatre records. Basic patient demographics, operative records and radiographs were collected and reviewed and data was analysed using Microsoft Excel. Failure of the PLAD was defined as further operative intervention after PLAD insertion and included: dislocation, implant breakage, infection and revision of the THA for loosening of either component. 55 PLADs were implanted in 54 patients with an average age of 77 years. There was a significant preponderance of females and a variety of surgical approaches had been used for the original hip replacement, including trochanteric osteotomy, posterior and antero-lateral. 9 (16%) patients had recurrent dislocations,1 (2%) failed secondary to screw breakage, 3 (5%) had and infection requiring intervention and 2 (4%) underwent further revision for aseptic loosening of the femoral component. The overall failure rate was 25% with 14 patients requiring intervention post PLAD. Our results are inferior to other published results and indicate that the PLAD should be used with caution for recurrent dislocations of the Charnley hip replacement.
Acute iatrogenic dislocation following hip impingement arthroscopic surgery.
Matsuda, Dean K
2009-04-01
This is the first case report of an iatrogenic anterior hip dislocation after arthroscopic surgery for femoroacetabular impingement with over 1 year of follow-up. This case report describes the clinical course of a patient with symptomatic cam-pincer femoroacetabular impingement. She underwent arthroscopic rim trimming, labral debridement after a failed attempt at labral refixation from suture cut-through, and femoral head-neck resection osteoplasty. The procedure involved supranormal hip distraction for extraction of an iatrogenic loose body (detached metallic radiofrequency probe tip). The patient had an anterior hip dislocation in the recovery room. Immediate closed reduction under general anesthesia and bracing were performed but failed despite the ability to obtain a concentric but grossly unstable reduction. After 3 failed attempts, a mini-open capsulorrhaphy was performed that successfully restored stability. Her postoperative management and outcome are presented. All of the major static stabilizers of the hip (osseous, labral, and capsuloligamentous) were surgically altered, and a multifactorial causation is proposed. Lessons learned are discussed in hopes of minimizing the occurrence of this rare but dramatic complication.
Krantz, Nicolas; Miletic, Bruno; Migaud, Henri; Girard, Julien
2012-09-01
Metal-on-metal hip resurfacing is offered as an alternative to traditional hip arthroplasty for young, active adults with advanced osteoarthritis. The concept of hip resurfacing is considered very attractive for this specific population (hard-on-hard bearing component with a large femoral head limiting the risk of dislocation, and allowing femoral bone stock preservation). A prospective clinical trial was designed to investigate the outcome of hip resurfacing in young patients (under 30 years old). We studied 24 hips in 22 patients. Mean age at operation was 24.9 years (range 17.1-29.9). No patient was lost to follow-up. There was no revision at average follow-up of 50.6 months (44-59). Mean UCLA activity score improved from 5.5 (1-9) pre-operatively to 7.6 (1-10) postoperatively (p < 0.001). Mean Harris hip score increased from 43.9 (19-67) to 89.3 (55-100) (p < 0.001). Radiological analysis discerned no osteolysis and no implant migration. The absence of short-term complications, such as mechanical failure or dislocation, is encouraging and leads us to think that mid-term results will be satisfactory. Moreover, the specific advantages of hip resurfacing (bone stock preservation, excellent stability, low risk of dislocation, large-diameter head) make the procedure a very attractive option for young subjects.
Duca, D; Pană, I; Ciovirnache, M; Simionesu, L; Ispas, I; Maxililian, C
1981-01-01
We reported an apparently previously undescribed syndrome, designated the coxoauricular syndrome, in a mother and her 3 daughters, all of whom shared in variable manner shortness of stature, minor vertebral and pelvic changes, dislocated hip(s), and microtia with corresponding hearing loss. The oldest daughter had coincidental Ullrich-Turner syndrome with 46, Xdel(X)(q 13) chromosome constitution. Inheritance of the trait in this family is dominant, either autosomal or X-linked, with hemizygote lethality.
The effect of unilateral osteoarthritis of the hip on postural balance disorders.
Truszczyńska, Aleksandra; Trzaskoma, Zbigniew; Białecki, Jerzy; Drzał-Grabiec, Justyna; Dadura, Emilia; Rąpała, Kazimierz; Tarnowski, Adam
2016-11-10
Postural stability is of great importance because imbalances and muscle weakness are significant risk factors for falls experienced by the elderly. Hip arthrosis, which causes pain and gait disorders that affect balance control, is common in the ageing population. The aim of this study was to assess postural stability in patients with unilateral hip arthrosis before total hip arthroplasty. The study population consisted of 52 patients with hip arthrosis (study group) and 47 subjects with no history of clinical symptoms of hip pain. The groups did not differ statistically in terms of age and BMI. Static balance was assessed by conducting a quantitative analysis of balance reaction parameters in a quiet standing position with the eyes open and closed. Analysis of the collected data revealed numerous statistically significant differences between patients with unilateral hip arthrosis before total hip arthoplasty and the asymptomatic group for parameters tested with eyes closed (p<0.05). We observed higher values of total length of centre of pressure (COP), sway path (SP), length of COP path in the medial-lateral plane (SPML), maximal amplitude between the 2 most distant points in the medial-lateral plane (MaxML), mean COP velocity (MV), and mean COP velocity in medial-lateral (MVML) in the study group.
Hip arthroscopy using the lateral approach.
Glick, J M
1988-01-01
The benefits of hip arthroscopy are apparent. It produces little postoperative morbidity and can be performed on an outpatient basis. The prompt recovery from the operation is also beneficial, particularly for elderly patients. Distraction of the hip by traction on a fracture table is necessary. Suggested indications for this procedure include synovectomy and synovial biopsy; removal of loose bodies; removal of debris after a closed reduction of a fracture-dislocation; evaluation and treatment of osteochondritis dissecans; evaluation for arthroplasty; and unresolved hip pain. Whether the lateral approach is useful in the following situations is yet to be explored: (1) Evaluation of pediatric conditions such as Legg-Perthes disease and congenital dislocated hip; (2) treatment of localized infection; (3) removal of entrapped methylmethacrylate in total hip replacement; and (4) reducing and fixating an acetabular fracture (M. Brennan, oral communication, April 6, 1987). Arthroscopy of the hip joint by the lateral approach is a valuable addition to the evaluation and treatment of hip disorders.
[Relevance of MRI After Closed Reduction of Traumatic Hip Dislocation in Children].
Strüwind, Christoph Mauritz; von Rüden, Christian; Thannheimer, Andreas; Bühren, Volker; Schneidmueller, Dorien
2018-05-14
Traumatic hip dislocation in children and adolescents is a rare entity that typically results from high-energy trauma. After closed joint reduction, further treatment depends on the specific pattern of the lesion as identified using cross sectional imaging. The aim of this retrospective analysis was to evaluate relevant side effects after traumatic hip dislocation in children and adolescents in order to examine the need for focused diagnostics. This retrospective analysis covered 8 adolescents under 18 years suffering isolated traumatic hip joint dislocation between 2001 and 2017. In all patients, closed joint reduction was performed immediately after admission to the emergency room. In order to evaluate the complete extent of the injury, 5 patients received an MRI and 3 patients a CT scan following closed joint reduction. Two female and 6 male patients with a median age of 11 (range 5 - 16) years were included. In 2 cases, a free joint body was detected in the posterior joint gap in the posttraumatic CT scan after closed joint reduction. Interposition of the labrum into the joint gap was detected intraoperatively in both cases. In one patient who received posttraumatic MRI, labral interposition into the joint gap was observed after closed reduction. These findings were confirmed intraoperatively. In 4 other patients, no posttraumatic labral lesion was detected in the MRI after closed reduction. The reported side effects included ruptured anterior inferior iliac spine and ruptured femoral head ligament. MRI is gaining increasing importance following traumatic hip dislocation in children and adolescents. A missing chondral or osteochondral fragment in the CT scan does not exclude a labral lesion or interposition. Therefore, MRI following closed reduction is mandatory in any case. Georg Thieme Verlag KG Stuttgart · New York.
Kanda, Akio; Kaneko, Kazuo; Obayashi, Osamu; Mogami, Atsuhiko; Morohashi, Itaru
2018-03-09
In total hip arthroplasty via a direct anterior approach, the femur must be elevated at the time of femoral implant placement. For adequate elevation, division of the posterior soft tissues is necessary. However, if we damage and separate the posterior muscle tissue, we lose the benefits of the intermuscular approach. Furthermore, damage to the posterior soft tissue can result in posterior dislocation. We investigate that protecting the posterior soft tissue increases the joint stability in the early postoperative period and results in a lower dislocation rate. We evaluated muscle strength recovery by measuring the maximum width of the internal obturator muscle on CT images (GE-Healthcare Discovery CT 750HD). We compared the maximum width of the muscle belly preoperatively versus 10 days and 6 months postoperatively. As clinical evaluations, we also investigated the range of motion of the hip joint, hip joint function based on the Japanese Orthopaedic Association hip score (JOA score), and the dislocation rate 6 months after surgery. The width of the internal obturator muscle increased significantly from 15.1 ± 3.1 mm before surgery to 16.4 ± 2.8 mm 6 months after surgery. The JOA score improved significantly from 50.8 ± 15.1 points to 95.6 ± 7.6 points. No dislocations occurred in this study. We cut only the posterosuperior articular capsule and protected the internal obturator muscle to preserve muscle strength. We repaired the entire posterosuperior and anterior articular capsule. These treatments increase joint stability in the early postoperative period, thus reducing the dislocation rate. Therapeutic, Level IV.
Outcomes after salvage procedures for the painful dislocated hip in cerebral palsy.
Wright, Patrick B; Ruder, John; Birnbaum, Mark A; Phillips, Jonathan H; Herrera-Soto, Jose A; Knapp, Dennis R
2013-01-01
The painful dislocated hip in the setting of cerebral palsy is a challenging problem. Many surgical procedures have been reported to treat this condition with varying success rates. The purpose of this study is to retrospectively evaluate and compare the outcomes of 3 different surgical procedures performed at our institution for pain relief in patients with spastic quadriplegic cerebral palsy and painful dislocated hips. A retrospective chart review of the surgical procedures performed by 5 surgeons for spastic, painful dislocated hips from 1997 to 2010 was performed. The procedures identified were (1) proximal femoral resection arthroplasty (PFRA); (2) subtrochanteric valgus osteotomy (SVO) with femoral head resection; and (3) proximal femur prosthetic interposition arthroplasty (PFIA) using a humeral prosthesis. Outcomes based on pain and range of motion were determined to be excellent, good, fair, or poor by predetermined criteria. Forty-four index surgeries and 14 revision surgeries in 33 patients with an average follow-up of 49 months met the inclusion criteria. Of the index surgeries, 12 hips were treated with a PFRA, 21 with a SVO, and 11 with a PFIA. An excellent or good result was noted in 67% of PFRAs, 67% of SVOs, and 73% of PFIAs. No statistical significance between these procedures was achieved. The 14 revisions were performed because of a poor result from previous surgery, demonstrating a 24% reoperation rate overall. No patients classified as having a fair result underwent revision surgery. All patients receiving revision surgery were eventually classified as having an excellent or good result. Surgical treatment for the painful, dislocated hip in the setting of spastic quadriplegic cerebral palsy remains unsettled. There continue to be a large percentage of failures despite the variety of surgical techniques designed to treat this problem. These failures can be managed, however, and eventually resulted in a good outcome. We demonstrated a trend toward better outcomes with a PFIA, but further study should be conducted to prove statistical significance. III.
Sabry, M A; al-Saleh, Q; al-Saw'an, R; al-Awadi, S A; Farag, T I
1995-07-01
A Somali female baby with right upper limb triplication, polythelia, left sided hemihypertrophy, congenital hip dislocation, facial dysmorphism, congenital heart disease, and scoliosis is described. It seems that the above described pattern of anomalies has not been reported before. The possible developmental genetic mechanism responsible for this phenotype is briefly discussed.
Fabry, Christian; Kaehler, Michael; Herrmann, Sven; Woernle, Christoph; Bader, Rainer
2014-01-01
Tripolar systems have been implanted to reduce the risk of recurrent dislocation. However, there is little known about the dynamic behavior of tripolar hip endoprostheses under daily life conditions and achieved joint stability. Hence, the objective of this biomechanical study was to examine the in vivo dynamics and dislocation behavior of two types of tripolar systems compared to a standard total hip replacement (THR) with the same outer head diameter. Several load cases of daily life activities were applied to an eccentric and a concentric tripolar system by an industrial robot. During testing, the motion of the intermediate component was measured using a stereo camera system. Additionally, their behavior under different dislocation scenarios was investigated in comparison to a standard THR. For the eccentric tripolar system, the intermediate component demonstrated the shifting into moderate valgus-positions, regardless of the type of movement. This implant showed the highest resisting torque against dislocation in combination with a large range of motion. In contrast, the concentric tripolar system tended to remain in varus-positions and was primarily moved after stem contact. According to the results, eccentric tripolar systems can work well under in vivo conditions and increase hip joint stability in comparison to standard THRs. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.
Bache, Christopher Edward; Graham, H Kerr; Dickens, D Robert V; Donnan, Leo; Johnson, Michael B; Nattrass, Gary; O'Sullivan, Mark; Torode, Ian P
2008-09-01
When closed reduction of a developmental dislocation of the hip fails, some form of open reduction is required. In recent years, the many advantages of the medial approach open reduction have been emphasized. However, there have been suggestions that the rate of growth disturbance in the proximal femur and the requirement for secondary surgical procedures may be higher with this route than with others. The purpose of this study was to investigate the efficacy and safety of a modified medial approach open reduction, in which the stability of the reduction is enhanced by resection of the redundant ligamentum teres and suturing of the stump of the tendon to the anteromedial capsule. The hospital records and radiographs of 92 infants and children with 109 dislocated hips were reviewed retrospectively. Key demographic and pretreatment data were collected by the first author and compared with the outcome at the most recent follow-up. In addition, 69 children returned for a clinical evaluation by the first author. The outcome at the most recent follow-up was graded according to Severin, and associations were sought between pretreatment grade of dislocation according to Tonnis, the presence of ossific nucleus, changes in the acetabular index, the requirements for secondary surgery, associations with previous treatment, and the position of abduction in the postoperative cast. At a mean follow-up of 9 years, 89% of hips were classified as Severin grade 1 or 2. Avascular necrosis (AVN) was classified according to the system of Kalamchi and MacEwen. The incidence of AVN was 41%, but two thirds of these were grade 1 (temporary irregular ossification), and the Severin grading in these hips was not compromised. The presence of ossification in the capital epiphysis and a range of abduction of less than 60 degrees in the hip spica were noted to be protective against the development of AVN. Three hips redislocated and required additional treatment. Thirty-eight hips required a total of 44 additional surgical procedures. We have demonstrated that it is possible to use a medial approach for open reduction of the congenitally dislocated hip in combination with tenodesis of the ligamentum teres to the anteromedial joint capsule. The incidence of growth disturbance in the proximal femur is high and cumulative with long-term follow-up. However, in this large series, the rate of hip stability, growth disturbance, and need for secondary surgery are comparable to other series. We conclude that the many advantages of open reduction by the medial approach outweigh the disadvantages.
Kobayashi, Seneki; Kubo, Toshikazu; Iwamoto, Yukihide; Fukushima, Wakaba; Sugano, Nobuhiko
2018-05-12
To identify modifiable factors related to post-operative dislocation and reoperation in patients with osteonecrosis of the femoral head (ONFH) in a large cohort. We studied 4995 hip arthroplasties: total hip arthroplasty (THA) was performed in 79% of patients; bipolar hemiarthroplasty (BP), 17%; total resurfacing arthroplasty (tRS), 3%; and hemi-resurfacing arthroplasty (hRS), 1%. A new type of BP (accounting for 49% of BPs) comprised a femoral component with a polished or smooth, small-diameter (approximately 10 mm) neck with a round or oval axial cut surface and no sharp corners. The infection rate was relatively low (0.56%) even though 58% of cases of ONFH were associated with systemic steroid use, a known risk factor for infection. Post-operative dislocation occurred in 4.3% of cases, with re-operation needed in 3.9%. The dislocation rate was related to surgery type: 5.2% in THA, 0.9% in BP, and 0% in tRS and hRS. Among total arthroplasties with six month or longer follow-up (3670 THAs and 159 tRSs), the risk factors for post-operative dislocation were younger (≤ 40 years) or older (≥ 62 years) age, higher body weight, posterolateral approach, and smaller prosthetic head diameter. Regarding the need for re-operation, higher body weight and surgery type were identified as risk factors. The relatively high dislocation rate of 5.2% in THA is a cause for concern. The identified risk factors for dislocation should be considered when selecting THA for treatment. Prosthesis survivorship in hRSs was inferior to that in BPs or THAs. Body weight also affected the survivorship of hip arthroplasties.
Akman, Yunus Emre; Yavuz, Umut; Çetinkaya, Engin; Gür, Volkan; Gül, Murat; Demir, Bilal
2018-03-01
We report the short-term outcomes of total hip arthroplasty(THA) in patients previously treated with Schanz osteotomy (SO). Eighteen patients [2 male, 16 female; mean age, 55.4 (range, 50-66) years] who had undergone THA after SO were retrospectively evaluated. Clinical evaluation was performed based on the Harris hip score. Radiological evaluation was performed using full-length radiographs of the lower extremities, pelvis, and hip. The mean follow-up period was 30.8 (range, 18-56) months. Mean femoral shortening was 3.7 (range, 2-5) cm. Perioperative complications occurred in 4 (22.2%) patients. Nonunion was not found at the osteotomy sites. No dislocation was observed. The Trendelenburg sign was positive for five (27.7%) patients, postoperatively. The mean Harris hip score improved from 42.7 to 78.7 (p < 0.05). THA for hips previously treated with SO is technically demanding. If careful preoperative planning is performed, successful treatment can be achieved.
Screening for developmental dysplasia of the hip.
Desprechins, B; Ernst, C; de Mey, J
2007-01-01
The reported prevalence of established dislocation the hip in an unscreened population varies from 0.7 to 1.6 / 1000 children in European and American white populations. In clinically screened populations neonatal hip instability is reported to occur in 3 to 30 / 1000 newborns while established congenital dislocation has a prevalence of 0.1- 4/1000 of which 1/1000 is judged to be in need for surgery. Early diagnosis of DDH is essential for successful treatment and later prognosis of the disorder. Combined procedure including evaluation of both hip morphology and hip stability is currently recommended. Opinions differ about the need for universal versus selective sonographic screening for diagnosis of DDH. Currently selective screening of those infants with recognised risk factors and those with abnormal physical examination would be cost-effective and the only practicable method for most countries.
Chronological changes in functional cup position at 10 years after total hip arthroplasty.
Okanoue, Yusuke; Ikeuchi, Masahiko; Takaya, Shogo; Izumi, Masashi; Aso, Koji; Kawakami, Teruhiko
2017-09-19
This study aims to clarify the chronological changes in functional cup position at a minimum follow-up of 10 years after total hip arthroplasty (THA), and to identify the risk factors influencing a significant difference in functional cup position during the postoperative follow-up period. We evaluated the chronological changes in functional cup position at a minimum follow-up of 10 years after THA in 58 patients with unilateral hip osteoarthritis. Radiographic cup position was measured on anteroposterior pelvic radiographs with the patient in the supine position, whereas functional cup position was recorded in the standing position. Radiographs were obtained before, 3 weeks after, and every 1 year after surgery. Functional cup anteversion (F-Ant) increased over time, and was found to have significantly increased at final follow-up compared to that at 3 weeks after surgery (p<0.01). The maximum postoperative change in F-Ant was 17.0° anteriorly; 12 cases (21%) showed a postoperative change in F-Ant by >10° anteriorly. Preoperative posterior pelvic tilt in the standing position and vertebral fractures after THA were significant predictors of increasing functional cup anteversion. Although chronological changes in functional cup position do occur after THA, their magnitude is relatively low. However, posterior impingement is likely to occur, which may cause edge loading, wear of the polyethylene liner, and anterior dislocation of the hip. We believe that, for the combined anteversion technique, the safe zone should probably be 5°-10° narrower in patients predicted to show considerable changes in functional cup position compared with standard cases.
Different methods of treatment related to the bilateral occurrence of Perthes' disease.
Futami, T; Suzuki, S
1997-11-01
We treated 98 consecutive patients with Perthes' disease by a unilateral brace in external rotation, flexion and abduction and a further consecutive 110 by a bilateral cast with the hips in internal rotation and abduction. During treatment in the unilateral brace, six (6.1%) hips on the opposite side developed evidence of Perthes' disease and one developed this after the brace had been removed. In children managed in bilateral casts, no contralateral Perthes' disease was seen. Adequate containment of the femoral head may prevent subsequent changes in the opposite hip.
Sabry, M A; al-Saleh, Q; al-Saw'an, R; al-Awadi, S A; Farag, T I
1995-01-01
A Somali female baby with right upper limb triplication, polythelia, left sided hemihypertrophy, congenital hip dislocation, facial dysmorphism, congenital heart disease, and scoliosis is described. It seems that the above described pattern of anomalies has not been reported before. The possible developmental genetic mechanism responsible for this phenotype is briefly discussed. Images PMID:7562971
Tins, Bernhard
2011-07-01
Metal on metal resurfacing hip implants are known to have complications unique to this type of implant. The case presented adds a further previously not described complication, the dislocation and spontaneous reduction of the pin of the femoral component against the femoral neck. The radiographic and CT findings are demonstrated. The dislocation was aided by bone loss due to an infection with a large periarticular collection. Periarticular collections in hip resurfacings are often due to a hypersensitivity type reaction to metal debris. However in the case presented it was due to infection. MRI was not able to discern the infection from a sterile collection. CT demonstrated bone loss and periosteal reaction suggestive of infection. In addition calcification of the pseudocapsule was seen, this is not a recognized feature of sterile collections. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
[Tripolar arthroplasty for recurrent total hip prosthesis dislocation].
Beaulé, P-E; Roussignol, X; Schmalzried, T-P; Udomkiat, P; Amstutz, H-C; Dujardin, F-H
2003-05-01
The purpose of this study was to assess the results of revision surgery for recurrent total hip prosthesis dislocation using a tripolar prosthesis composed of a conventional stem with a mobile head of an intermediary prosthesis measuring more than 40 mm and a modified cup. This technique was used in two centers in Rouen France and Los Angeles USA. Twenty-one hips in 21 patients were operated on. The mobile heads measured 40 to 47 mm. Mean patient age was 70 years (range 29-92). The indication for the tripolar prosthesis was reserved for extremely unstable hips in patients with major risk factors for recurrent dislocation. These 21 patients had experienced 95 dislocations. The acetabular cup was custom-made for the large-diameter heads. A cemented polyethylene cup was used in 14 cases and a press-fit metal-backed around a polyethylene insert in 7. The polyethylene thickness varied from 6.5 to 16 mm for the cemented cups and 4 to 5 mm for the press-fit cups. Fourteen femoral stems were left in place as were two press-fit cups where only the inserts were changed. Mean follow-up was 5.4 years (range 3-11.8). There has been no recurrent dislocation for 20 hips. One patient experienced a dislocation one week after surgery which required a second revision procedure to reposition the acetabular implant. Final outcome was good at 7.6 years for this hip. One patient who had not had any recurrent dislocation died 4 years after the revision surgery due to a cause unrelated to the prosthesis. Two patients were lost to follow-up at 3.7 and 6 years, both were pain free and had no radiological anomalies. Infection occurred in one patient undergoing chemotherapy for a myeloma; the head and neck had to be resected. For the 20 other patients, functional outcome, assessed with the UCLA score, showed improvement in pain (5.8 preoperatively, 9.2 at last follow-up), walking (4.8 and 8 respectively), function (4 and 6 respectively), and daily activities (3.3 and 5.2 respectively). A revision procedure was necessary for one patient during the 4(th) year because of a fracture of the polyethylene insert on a metal-back cup; the insert alone was changed. Excepting the patient with infection, there were no cases of certain or probable loosening during the follow-up. The tripolar prosthesis with a mobile cup and a large-diameter head appears to be a reliable solution for these severely unstable hips. The procedure can often be limited to the acetabular component, reducing morbidity. The thickness of the polyethylene cup is a limitation which may affect long-term survival. Search for a highly wear-resistant couple continues.
Palencia, Jesús; Alfayez, Saud; Serro, Firas; Alqahtani, Jamal; Alharbi, Hani; Alhinai, Hamed
2016-01-01
Femoral head and neck fractures in children are uncommon, accounting for fewer than 1% of all pediatric fractures and fewer than 8% of all hip fractures. Furthermore, traumatic transphyseal hip fracture is rare to present in daily practice especially when associated with an acetabular fracture. A twelve years old boy, not known to have any chronic illnesses, presented to the emergency department as a case of polytrauma after a road traffic accident. Signs of left hip dislocation were discovered upon physical examination. X-rays and CT scans, revealed a complete transphyseal posterior dislocation and a left anterior column fracture of the acetabulum with a minimal displacement. Within five hours, the patient underwent open reduction and internal fixation by two cannulated screws. The acetabular fracture was managed conservatively. After six months, there were clear signs of osteonecrosis of the femoral head. A high-energy trauma in children and adolescents can lead to simultaneous epiphyseal and acetabular fractures which are associated with a poor prognosis. The age seems to play a role as patients older than ten years have a higher risk of developing AVN after sustaining a hip dislocation regardless of the time of intervention. Epiphyseal fracture with dislocation of the femoral head is rare among children and adolescents, especially when associated with an acetabular fracture. AVN in such cases can develop, and it represents a challenge to orthopedic surgeons due to the poor prognosis and the future functional limitations of the joint. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Rafn, Bolette S; Tang, Lars; Nielsen, Martin P; Branci, Sonia; Hölmich, Per; Thorborg, Kristian
2016-05-01
To investigate whether self-reported pain during hip strength testing correlates to a large degree with hip muscle strength in soccer players with long-standing unilateral hip and groin pain. Cross-sectional study. Clinical assessments at Sports Orthopaedic Research Center-Copenhagen (SORC-C), Arthroscopic Centre Amager, Copenhagen University Hospital, Denmark. Twenty-four male soccer players with unilateral long-standing hip and groin pain. The soccer players performed 5 reliable hip muscle strength tests (isometric hip flexion, adduction, abduction, isometric hip flexion-modified Thomas test, and eccentric hip adduction). Muscle strength was measured with a hand-held dynamometer, and the players rated the pain during testing on a numerical rating scale (0-10). In 4 tests (isometric hip adduction, abduction, flexion, and eccentric adduction), no significant correlations were found between pain during testing and hip muscle strength (Spearman rho = -0.28 to 0.06, P = 0.09-0.39). Isometric hip flexion (modified Thomas test position) showed a moderate negative correlation between pain and hip muscle strength (Spearman rho = -0.44, P = 0.016). Self-reported pain during testing does not seem to correlate with the majority of hip muscle strength tests used in soccer players with long-standing hip and groin pain.
Complication Rates for Hip Arthroscopy Are Underestimated: A Population-Based Study.
Truntzer, Jeremy N; Hoppe, Daniel J; Shapiro, Lauren M; Abrams, Geoffrey D; Safran, Marc
2017-06-01
To identify major and minor complication rates associated with hip arthroscopy from a payer-based national database and compare with the rates reported in the existing literature. Patients who underwent hip arthroscopy between 2007 and 2014 were identified using PearlDiver, a publicly available database. Rates of major and minor complications, as well as conversion to total hip arthroscopy (THA), were determined by using Current Procedural Terminology (CPT) and International Classification of Diseases, Ninth Revision (ICD-9), codes. Incidence rates of select major complications across the entire database were used as a comparison group. Statistical significance was set at P < .05. Of 18 million patients screened from 2007 to 2014, a total of 2,581 hip arthroscopies were identified. The rates of major and minor complications within a 1-year postoperative period were 1.74% and 4.22%, respectively. Complications included heterotopic ossification (2.85%), bursitis (1.23%), proximal femur fracture (1.08%), deep vein thrombosis (0.79%), and hip dislocation (0.58%). The rate of conversion to THA within 1 year was 2.85%. When compared to rates in the general population, the relative risks [RRs] of requiring a THA (age <50 years, RR = 57.66, P < .001; age >50 years, RR = 22.05, P < .001), sustaining a proximal femur fracture (age <50 years, RR = 18.02, P < .001; age >50 years, RR = 2.23, P < .001), or experiencing a hip dislocation (RR 19.60, P < .001) at 1 year after hip arthroscopy were significantly higher in all age groups. Higher major complication rates after hip arthroscopy were observed using a national payer-based database than previously reported in the literature, especially in regard to hip dislocations and proximal femur fractures. Rates of total hip arthroplasty were similar to prior studies, whereas the rates of revision hip arthroscopy were higher. Level IV, case series. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
... dwarfism might have: cleft palate hand and ear differences hip dysplasia club feet severe curvature of the spine early deterioration of joints and joint stiffness potential hip and knee dislocation Complications From Spondyloepiphyseal Dysplasia ...
Walking efficiency before and after total hip replacement.
Brown, M; Hislop, H J; Waters, R L; Porell, D
1980-10-01
The energy cost of walking and gait characteristics of patients with hip disease were studied to determine changes in walking efficiency following total hip replacement. Twenty-nine patients, 24 with unilateral hip disease and 5 with bilateral hip disease, were tested preoperatively and at various times postoperatively. Oxygen uptake was measured by a modified Douglas bag procedure. The temporal and distance characteristics of gait were measured with contact closing heel switches. Results showed postoperative increases in velocity, cadence, and stride length in patients with unilateral disease and with bilateral disease with bilateral replacement. After surgery, energy cost tended toward more normal levels, but the subjects were not within normal limits for oxygen uptake per minute, oxygen uptake per distance walked, or percent of predicted maximum aerobic capacity. Comparison of energy expenditure data with temporal and distance factors of gait indicated that all subjects became more physiologically efficient after hip replacement.
Davies, Simon R
2011-03-01
Vertebral artery damage after cervical fracture and especially cervical dislocations is a recognized phenomenon. The incidence of significant intracranial neurology after unilateral vertebral damage is extremely rare, and to our knowledge, no such injury has been sustained while playing sport. To describe a rare vascular complication of a bifacet C5-C6 dislocation. Case report and clinical discussion. We present a 28-year old white man who was a professional rugby player. He sustained a hyperflexion injury while playing scrum half in a recent league match, which resulted in a C5-C6 dislocation, diagnosed clinically and with a plain radiograph. The patient on admission had complete neurologic loss below C6. The patient underwent immediate computed tomography and magnetic resonance imaging (MRI) scans that revealed a 50% displacement of C5 on C6 with a complete unifacet dislocation and the other facet partially dislocated. The MRI revealed signal changes in the cord at the C5-C6 level and an intimal tear in the left vertebral artery. The decision was taken to reduce the dislocation when medically stable. A few hours after injury, after an episode of vomiting, the patient sustained a respiratory arrest owing to the embolization of a clot from the left vertebral artery into the basilar artery. Despite rapid embolectomy and subsequent permanent left vertebral artery occlusion, the patient sustained multiple infarcts in the cerebellar, thalamic, occipital, and pontine regions of the brain that eventually proved fatal. This case shows a rare complication of unilateral vertebral artery occlusion. Despite early identification of a basilar infarct and a successful embolectomy, intracranial infarction occurred. Although there is no guideline for the treatment of vertebral artery damage, early reduction and anticoagulation may reduce the risk of cerebral infarction. Copyright © 2011 Elsevier Inc. All rights reserved.
Position of the prosthesis and the incidence of dislocation following total hip replacement.
He, Rong-xin; Yan, Shi-gui; Wu, Li-dong; Wang, Xiang-hua; Dai, Xue-song
2007-07-05
Dislocation is the second most common complication of hip replacement surgery, and impact of the prosthesis is believed to be the fundamental reason. The present study employed Solidworks 2003 and MSC-Nastran software to analyze the three dimensional variables in order to investigate how to prevent dislocation following hip replacement surgery. Computed tomography (CT) imaging was used to collect femoral outline data and Solidworks 2003 software was used to construct the cup model with variabilities. Nastran software was used to evaluate dislocation at different prosthesis positions and different geometrical shapes. Three dimensional movement and results from finite element method were analyzed and the values of dislocation resistance index (DRI), range of motion to impingement (ROM-I), range of motion to dislocation (ROM-D) and peak resisting moment (PRM) were determined. Computer simulation was used to evaluate the range of motion of the hip joint at different prosthesis positions. Finite element analysis showed: (1) Increasing the ratio of head/neck increased the ROM-I values and moderately increased ROM-D and PRM values. Increasing the head size significantly increased PRM and to some extent ROM-I and ROM-D values, which suggested that there would be a greater likelihood of dislocation. (2) Increasing the anteversion angle increased the ROM-I, ROM-D, PRM, energy required for dislocation (ENERGY-D) and DRI values, which would increase the stability of the joint. (3) As the chamber angle was increased, ROM-I, ROM-D, PRM, Energy-D and DRI values were increased, resulting in improved joint stability. Chamber angles exceeding 55 degrees resulted in increases in ROM-I and ROM-D values, but decreases in PRM, Energy-D, and DRI values, which, in turn, increased the likelihood of dislocation. (4) The cup, which was reduced posteriorly, reduced ROM-I values (2.1 -- 5.3 degrees ) and increased the DRI value (0.073). This suggested that the posterior high side had the effect of 10 degrees anteversion angle. Increasing the head/neck ratio increases joint stability. Posterior high side reduced the range of motion of the joint but increased joint stability; Increasing the anteversion angle increases DRI values and thus improve joint stability; Increasing the chamber angle increases DRI values and improves joint stability. However, at angles exceeding 55 degrees , further increases in the chamber angle result in decreased DRI values and reduce the stability of the joint.
Sucato, Daniel J; De La Rocha, Adriana; Lau, Karlee; Ramo, Brandon A
2017-03-01
Preoperative Bryant's overhead traction before closed reduction (CR) in developmental dysplasia of the hip (DDH) remains controversial and its success in increasing CR rates and reducing avascular necrosis (AVN) rates has not been specifically reported in a large cohort. IRB-approved retrospective study of patients (below 3 y)who were treated with attempted CR for idiopathic DDH from 1980 to 2009. Successful CR was defined as a hip that remained reduced and did not require repeat CR or open reduction. Patients were grouped by age, hip instability [Ortolani positive (reducible) vs. fixed dislocation], and Tonnis classification and rates of successful CR were compared between groups with P<0.05. A total of 342 hips were included with a mean age of 0.9 years (0.2 to 2.8 y) and a mean follow-up of 10.4 years (2.0 to 27.7 y). There were 269 hips with fixed dislocations and 73 Ortolani-positive hips. Traction was used in 276 hips. There was no difference in traction utilization in the 3 age groups (below 1, below 1.5, and below 2 y) for either Ortolani-positive hips (P=0.947) or fixed dislocations (P=0.943). There was no difference in achieving a successful CR comparing traction (60.9%) and no-traction groups (60.6%) (P=1.00). For Ortolani-positive hips, traction did not improve the incidence of a successful CR for any age group: below 1 year: P=0.19; below 1.5 years: P=0.23; and below 2 years: P=0.25. Similarly, fixed dislocation patients had no benefit from traction: below 1 year: P=0.76; below 1.5 years: P=0.82; and below 2 years: P=0.85. Tonnis classification did predict success of CR but had no influence on traction success. There was no difference in the rate of AVN between the traction (18%) and no-traction (8%) groups for all patients (P=0.15). In this retrospective series, preoperative Bryant's traction does not improve the rate of a successful CR for patients with DDH and has no protective effect on the development of AVN of the femoral head. These results suggest that Bryant's overhead traction may not be warranted for patients below 3 years of age with DDH. Level III.
Bilateral femoral neck stress fractures in military recruits with unilateral hip pain.
Moo, Ing How; Lee, Y H D; Lim, K K; Mehta, K V
2016-10-01
Femoral neck stress fractures are rare and can be easily missed and failure to diagnose these injuries early can lead to avascular necrosis, malunion and osteoarthritis. It is important to have a high index of suspicion for femoral neck stress fractures in military recruits. We present three cases of bilateral femoral neck fractures in military recruits, all presenting with unilateral hip symptoms and signs. All the asymptomatic contralateral hips had femoral neck stress fractures diagnosed by screening MRI. Tension type and displaced femoral neck fractures were treated surgically. All the fractures managed healing without complications. Military recruits with unilateral groin pain should have an early referral for MRI hip to rule out femoral neck stress fractures and those military personnel with ipsilateral femoral neck fracture should have MRI of the contralateral hip. Two of the patients had vitamin D deficiency, of which one had elevated parathyroid hormones and low bone mineral density. Our case series highlights the significance of vitamin D deficiency among military recruits. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Zijlstra, Wierd P; De Hartog, Bas; Van Steenbergen, Liza N; Scheurs, B Willem; Nelissen, Rob G H H
2017-01-01
Background and purpose Recurrent dislocation is the commonest cause of early revision of a total hip arthropasty (THA). We examined the effect of femoral head size and surgical approach on revision rate for dislocation, and for other reasons, after total hip arthroplasty (THA). Patients and methods We analyzed data on 166,231 primary THAs and 3,754 subsequent revision THAs performed between 2007 and 2015, registered in the Dutch Arthroplasty Register (LROI). Revision rate for dislocation, and for all other causes, were calculated by competing-risk analysis at 6-year follow-up. Multivariable Cox proportional hazard regression ratios (HRs) were used for comparisons. Results Posterolateral approach was associated with higher dislocation revision risk (HR =1) than straight lateral, anterolateral, and anterior approaches (HR =0.5–0.6). However, the risk of revision for all other reasons (especially stem loosening) was higher with anterior and anterolateral approaches (HR =1.2) and lowest with posterolateral approach (HR =1). For all approaches, 32-mm heads reduced the risk of revision for dislocation compared to 22- to 28-mm heads (HR =1 and 1.6, respectively), while the risk of revision for other causes remained unchanged. 36-mm heads increasingly reduced the risk of revision for dislocation but only with the posterolateral approach (HR =0.6), while the risk of revision for other reasons was unchanged. With the anterior approach, 36-mm heads increased the risk of revision for other reasons (HR =1.5). Interpretation Compared to the posterolateral approach, direct anterior and anterolateral approaches reduce the risk of revision for dislocation, but at the cost of more stem revisions and other revisions. For all approaches, there is benefit in using 32-mm heads instead of 22- to 28-mm heads. For the posterolateral approach, 36-mm heads can safely further reduce the risk of revision for dislocation. PMID:28440704
Alamdaran, Seyed Ali; Kazemi, Sahar; Parsa, Ali; Moghadam, Mohammad Hallaj; Feyzi, Ali; Mardani, Reza
2016-01-01
Background: Developmental dysplasia of hip (DDH) is a common childhood disorder, and ultrasonography examination is routinely used for screening purposes. In this study, we aimed to evaluate a modified combined static and dynamic ultrasound technique for the detection of DDH and to compare with the results of static and dynamic ultrasound techniques. Methods: In this cross-sectional study, during 2013- 2015, 300 high-risk infants were evaluated by ultrasound for DDH. Both hips were examined with three techniques: static, dynamic and single view static and dynamic technique. Statistical analysis was performed using SPSS version 11.5. Results: Patients aged 9 days to 83 weeks. 75% of the patients were 1 to 3 months old. Among 600 hip joints, about 5% were immature in static sonography and almost all of them were unstable in dynamic techniques. 0.3% of morphologically normal hips were unstable in dynamic sonography and 9% of unstable hips had normal morphology. The mean β angle differences in coronal view before and after stress maneuver was 14.43±5.47° in unstable hips. Single view static and dynamic technique revealed that all cases with acetabular dysplasia, instability and dislocation, except two dislocations, were detected by dynamic transverse view. For two cases, Ortolani maneuver showed femoral head reversibility in dislocated hips. Using single view static and dynamic technique was indicative and applicable for detection of more than 99% of cases. Conclusion: Single view static and dynamic technique not only is a fast and easy technique, but also it is of high diagnostic value in assessment of DDH. PMID:27847852
Kornuijt, A; Das, D; Sijbesma, T; van der Weegen, W
2016-05-01
In order to prevent dislocation of the hip after total hip arthroplasty (THA), patients have to adhere to precautions in the early post-operative period. The hypothesis of this study was that a protocol with minimal precautions after primary THA using the posterolateral approach would not increase the short-term (less than three months) risk of dislocation. We prospectively monitored a group of unselected patients undergoing primary THA managed with standard precautions (n = 109, median age 68.9 years; interquartile range (IQR) 61.2 to 77.3) and a group who were managed with fewer precautions (n = 108, median age 67.2 years; IQR 59.8 to 73.2). There were no significant differences between the groups in relation to predisposing risk factors. The diameter of the femoral head ranged from 28 mm to 36 mm; meticulous soft-tissue repair was undertaken in all patients. The medical records were reviewed and all patients were contacted three months post-operatively to confirm whether they had experienced a dislocation. There were no dislocations in the less restricted group and one in the more restricted group (p = 0.32). For experienced surgeons using the posterolateral approach at THA and femoral heads of diameter ≥ 28 mm, it appears safe to manage patients in the immediate post-operative period with minimal precautions to protect against dislocation. Larger studies with adequate statistical power are needed to verify this conclusion. Experienced orthopaedic surgeons using the posterolateral approach for THA should not fear an increased dislocation rate if they manage their patients with a minimal precautions protocol. Cite this article: Bone Joint J 2016;98-B:589-94. ©2016 The British Editorial Society of Bone & Joint Surgery.
21 CFR 890.3665 - Congenital hip dislocation abduction splint.
Code of Federal Regulations, 2010 CFR
2010-04-01
... SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890... abduction splint is a device intended for medical purposes to stabilize the hips of a young child with...
Lawrey, Emma; Jones, Peter; Mitchell, Robin
2012-04-01
Prosthetic hip dislocation is common. This study compares prosthetic hip relocations attempted within the ED by emergency doctors and those under orthopaedic care in the ED or operating theatre (OT). Retrospective cohort study of patients presenting to Auckland City Hospital Adult Emergency Department with prosthetic hip dislocations between 1 January 2003 and 14 April 2008. Primary outcomes were proportion of successful relocation attempts and length of hospital stay. Secondary outcomes were: time to relocation, complications, post-procedural advice, representation rate and long-term outcomes for first-time dislocations. There were 410 eligible presentations during the study period. Emergency medicine (EM) was successful in 254/323 attempts (79%, 95% confidence interval [CI] 74-83). Orthopaedics were successful in 25/35 reductions in the ED (71%, 95% CI 55-84) and 49/51 OT attempts (96%, 95% CI 86-100), P = 0.004 for location OT versus ED. Median times to discharge were 8.8 h for EM, 28.3 h for orthopaedics in the ED and 81 h for orthopaedics in the OT, P < 0.001 for EM versus orthopaedics. Mechanical complications of procedures and early redislocations were infrequent. Complication of sedation were more often seen in OT compared to ED (23/47 [49%, 95% CI 35-63]vs 37/318 [12%, 95% CI 9-16]). There was no difference between EM and orthopaedics in the proportion of hips successfully relocated or complications in the ED; however, EM patients were discharged much sooner, with important resource implications. Procedures carried out in the OT were more successful than in the ED but resulted in prolonged hospital stays and were associated with more complications. © 2012 The Authors. EMA © 2012 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.
Kemp, Joanne L; Risberg, May Arna; Schache, Anthony G; Makdissi, Michael; Pritchard, Michael G; Crossley, Kay M
2016-11-01
Study Design Cross-sectional study. Background Functional task performance in patients with chondrolabral pathology following hip arthroscopy is unknown. Objectives To investigate in people with chondrolabral pathology following hip arthroscopy (1) the bilateral differences in functional task performance compared to controls, (2) the association of hip muscle strength with functional task performance, and (3) the association of functional task performance scores with good outcome, as measured by International Hip Outcome Tool score. Methods Seventy-one patients who had unilateral hip arthroscopy for hip pain and 60 controls were recruited. Patient-reported outcomes included the 4 subscales of the International Hip Outcome Tool. Hip muscle strength measures included abduction, adduction, extension, flexion, external rotation, and internal rotation. Functional tasks assessed included the single hop test, the side bridge test, and the single-leg rise test. For aim 1, analyses of covariance tests were used. For aim 2, stepwise multiple linear regression analyses were used. For aim 3, receiver operating characteristic curve analyses were used. Results Compared to controls, the chondrolabral pathology group had significantly worse performance on both legs for each of the functional tasks (P<.001). Greater hip abduction strength was moderately associated with better performance on functional tasks in the chondrolabral pathology group (adjusted R 2 range, 0.197-0.407; P<.001). Cutoff values associated with good outcome were 0.37 (hop distance/height) for the single hop, 16 repetitions for the single-leg rise, and 34 seconds for the side bridge test. Conclusion Patients with hip chondrolabral pathology had reduced functional task performance bilaterally 12 to 24 months after unilateral hip arthroscopy when compared to controls. Level of Evidence Therapy/symptom prevalence, level 3b. J Orthop Sports Phys Ther 2016;46(11):947-956. doi:10.2519/jospt.2016.6577.
[Derotational subtrochanteric osteotomy of the femur in celebral palsy patients].
Schejbalová, A
2006-10-01
Derotational subtrochanteric osteotomy as an independent surgical procedure is one of the options for treatment of hip anteversion in adolescent patients with cerebral palsy. In other indications it is one of combined surgical procedures for hip joint reconstruction. During the 1992-2005 period, derotational subtrochanteric osteotomy was indicated in 74 cases, in ambulatory patients 9 to 18 years old, with diplegic or hemiplegic cerebral plasy. In 63 cases it was used a part of combined surgery. The postoperative evaluation was based on clinical and radiographic findings, migration rates and Wiberg's CE angle obtained at 2 and 6 months, and then at each 6 months following surgery. Derotational subtrochanteric osteotomy alone always resulted in improvement of clinical status and an increase in Wiberg's CE angle by 10 degrees on average. Patients with marginal or high dislocation showed best results when the hip joint was reconstructed before the age of 9 years. In three hips a recurrent dislocation occurred gradually within one year of surgery. These patients fell back to stage II of the Vojta classification found preoperatively. During the next three years, three more hips developed a recurrent dislocation and two showed lateralization (20 %). Reconstructive surgery for neurogenic dislocation in patients over 10 years of age is associated with problems, as is derotation combined with varus osteotomy in abductor insufficiency. On the other hand, derotational subtrochanteric osteotomy alone is indicated particularly in children over 10 years, in whom it corrects hip joint anteversion and improves gait. Complete reconstructive procedures should be considered in the first 10 years of life when neither the femoral head nor the acetabulum are markedly changed. Derotative osteotomy alone is preferred to procedures combined with varus osteotomy. In walking adolescent patients, derotative femoral osteotomy alone is recommended; this can exceptionally be used at earlier age if marked asymmetry is present.
[Effect of abducens orthosis combined with walker on developmental dysplasia of the hip].
Hu, Zhiyong; Xu, Yongqiang; Liang, Jieyu; Li, Kanghua; Liao, Qiande
2009-07-01
To evaluate the effect of abducens orthosis combined with walker on developmental dysplasia of the hip (DDH). A total of 126 patients (224 hips) with DDH aged 6-36 months in Xiangya Hospital was randomly divided into 2 groups: an orthosis combined with walker group and an improved hip frog cast fixation group. Seventy patients (130 hips) were treated by the orthosis combined with walker and 56 patients (94 hips) were treated by the improved hip frog cast fixation. We compared the effect and complications of the 2 groups. The fineness rates of the orthosis combined with walker group and the improved hip frog cast fixation group were 89.2% and 90.4%, respectively, with no significant difference (P>0.05). The rate of femoral head osteonecrosis in the orthosis combined with walker group was significantly lower than that in the improved hip frog cast fixation group (1.5% vs. 5.3%,P<0.05), but the re-dislocation rate in the former was significantly higher than that in the latter (6.9% vs. 1.1 %, P<0.05). Both methods are effective for DDH. Orthosis combined with walker has a lower proportion of femoral head osteonecrosis, but a higher proportion of re-dislocation.
Koczewski, P; Napiontek, M
2001-08-01
We studied 10 patients treated because of late avascular necrosis (AVN) mimicking Legg-Calvé-Perthes' disease (LCPD) after developmental dislocation of the hip (DDH). DDH was recognized late at an average age of 5.4 months and in all children it was treated without surgery. In 4 children, the treatment was complicated by mild AVN of the femoral head, which had disappeared before 3 years of age. The first clinical signs of LCPD were noted at a mean age of 5.8 years. They all had Catterall's type III or IV of LCPD. The course was typical of LCPD. 8 children were operated on at mean age of 7.4 (5-12) years. In 7 of them, subtrochanteric derotation-varisation osteotomy of the femur with shortening combined mainly with Dega's pelvic osteotomy was done. The operative treatment resulted in a concentric position of the femoral head and good coverage of the acetabulum. Follow-ups were done at 10 (6-35) years. Shortened femoral neck and trochanteric overgrowth occurred in 4 operated hips. According to the Stulberg classification, 2 hips were classified as type I, 1 as I/II, 5 as II/I as II/III and 1 as IV. We conclude that LCPD mimicking late AVN can occur in hips treated because of developmental dislocation.
Evaluation and Referral for Developmental Dysplasia of the Hip in Infants.
Shaw, Brian A; Segal, Lee S
2016-12-01
Developmental dysplasia of the hip (DDH) encompasses a wide spectrum of clinical severity, from mild developmental abnormalities to frank dislocation. Clinical hip instability occurs in 1% to 2% of full-term infants, and up to 15% have hip instability or hip immaturity detectable by imaging studies. Hip dysplasia is the most common cause of hip arthritis in women younger than 40 years and accounts for 5% to 10% of all total hip replacements in the United States. Newborn and periodic screening have been practiced for decades, because DDH is clinically silent during the first year of life, can be treated more effectively if detected early, and can have severe consequences if left untreated. However, screening programs and techniques are not uniform, and there is little evidence-based literature to support current practice, leading to controversy. Recent literature shows that many mild forms of DDH resolve without treatment, and there is a lack of agreement on ultrasonographic diagnostic criteria for DDH as a disease versus developmental variations. The American Academy of Pediatrics has not published any policy statements on DDH since its 2000 clinical practice guideline and accompanying technical report. Developments since then include a controversial US Preventive Services Task Force "inconclusive" determination regarding usefulness of DDH screening, several prospective studies supporting observation over treatment of minor ultrasonographic hip variations, and a recent evidence-based clinical practice guideline from the American Academy of Orthopaedic Surgeons on the detection and management of DDH in infants 0 to 6 months of age. The purpose of this clinical report was to provide literature-based updated direction for the clinician in screening and referral for DDH, with the primary goal of preventing and/or detecting a dislocated hip by 6 to 12 months of age in an otherwise healthy child, understanding that no screening program has eliminated late development or presentation of a dislocated hip and that the diagnosis and treatment of milder forms of hip dysplasia remain controversial. Copyright © 2016 by the American Academy of Pediatrics.
Framing Hip Hop: New Methodologies for New Times
ERIC Educational Resources Information Center
Dimitriadis, Greg
2015-01-01
This article revisits the central impulse behind early advocacy for ethnographic approaches to hip hop--that critics should try as much as possible to limit their own certainties around what hip hop can and might mean. While ethnographic approaches can engender the kinds of personal dislocations that allow for this negotiation, they do not…
Leijendekkers, Ruud A; Marra, Marco A; Kolk, Sjoerd; van Bon, Geert; Schreurs, B Wim; Weerdesteyn, Vivian; Verdonschot, Nico
2018-01-01
Untreated unilateral developmental dysplasia of the hip (DDH) results in asymmetry of gait and hip strength and may lead to early osteoarthritis, which is commonly treated with a total hip arthroplasty (THA). There is limited knowledge about the obtained symmetry of gait and hip strength after the THA. The objectives of this cross-sectional study were to: a) identify asymmetries between the operated and non-operated side in kinematics, kinetics and hip strength, b) analyze if increased walking speed changed the level of asymmetry in patients c) compare these results with those of healthy subjects. Women (18-70 year) with unilateral DDH who had undergone unilateral THA were eligible for inclusion. Vicon gait analysis system was used to collect frontal and sagittal plane kinematic and kinetic parameters of the hip joint, pelvis and trunk during walking at comfortable walking speed and increased walking speed. Furthermore, hip abductor and extensor muscle strength was measured. Six patients and eight healthy subjects were included. In the patients, modest asymmetries in lower limb kinematics and kinetics were present during gait, but trunk lateral flexion asymmetry was evident. Patients' trunk lateral flexion also differed compared to healthy subjects. Walking speed did not significantly influence the level of asymmetry. The hip abduction strength asymmetry of 23% was not statistically significant, but the muscle strength of both sides were significantly weaker than those of healthy subjects. In patients with a DDH treated with an IBG THA modest asymmetries in gait kinematics and kinetics were present, with the exception of a substantial asymmetry of the trunk lateral flexion. Increased walking speed did not result in increased asymmetries in gait kinematics and kinetics. Hip muscle strength was symmetrical in patients, but significantly weaker than in healthy subjects. Trunk kinematics should be included as an outcome measure to assess the biomechanical benefits of the THA surgery after DDH.
Andersson, J E; Odén, A
2001-08-01
The aim of this study was to evaluate the frequency and type of hip-joint instability and the frequency of hip dislocation requiring treatment in neonates who had been lying in the breech presentation and were delivered vaginally after an external version or by caesarean section, and to compare them with neonates who were naturally in the vertex presentation. Breech presentations without ongoing labour were subjected to an attempted external version and, in cases where this proved unsuccessful or where labour had started, to deliver by caesarean section. None of the breech presentations was vaginally delivered. The anterior-dynamic ultrasound method was used to assess the hip-joint status of the neonates. Out of 6,571 foetuses, 257 were in breech presentation after 36 wk of pregnancy. Sixty-two were vaginally delivered following an external version to vertex presentation and 195 were delivered by caesarean section, 75 of these following unsuccessful attempts to perform a version. Treatment for congenital hip-joint dislocation was performed on 0.2%. Out of the breech presentations, 1.0% of those delivered by caesarean section were treated, while in those with vaginal delivery following an external version the treatment frequency was 3.2%. No case of late diagnosed hip dislocation was recorded. Significant differences in frequency of hip-joint instability and treatment were found between (i) neonates delivered in breech presentation and those delivered with vertex presentation, (ii) infants delivered in vertex presentation, naturally or after successful version, and (iii) those delivered by caesarean section with or without attempted external version and those delivered with vortex presentation. Breech presentation predisposes to increased hip instability. The instability is present prior to delivery and is certainly not a primary result of delivery forces. Both breech and vertex presentations following an external or spontaneous version should be considered as risk factors for neonatal hip instability.
Elzinga, L; Marcus, M; Peek, D; Borg, P; Jansen, J; Koster, J; Enk, D
2009-01-01
We report the case of an 89-year-old female with a history of arterial hypertension, intermittent rapid atrial fibrillation and severe aortic valve stenosis, suffering from femoral neck fracture. Hyperbaric unilateral spinal anesthesia is a known technique to obtain stable hemodynamics combined with the possibility of continuous neurologic evaluation and preservation of cognitive functions. Because a hyperbaric unilateral technique can be very painful in case of traumatic hip fracture, a low dose, low volume, unilateral hypobaric spinal block may be an adequate alternative. In the present case report, a unilateral hypobaric spinal anesthesia was performed using 5 mg of bupivacaine in a 1.5 mL volume and a slow and steady, "air-buffered", directed injection technique, to allow an urgent hip arthroplasty. During surgery the patient was kept in the lateral recumbent position. Hemodynamics remained stable throughout the entire procedure without any need for vasoconstrictors. The impact of aortic valve stenosis combined with atrial fibrillation on anesthetic management and our considerations to opt for a unilateral hypobaric spinal anesthesia are discussed.
Intractable bone marrow edema syndrome of the hip.
Gao, Fuqiang; Sun, Wei; Li, Zirong; Guo, Wanshou; Kush, Nepali; Ozaki, Koji
2015-04-01
There is a need for an effective and noninvasive treatment for intractable bone marrow edema syndrome of the hip. Forty-six patients with intractable bone marrow edema syndrome of the hip were retrospectively studied to compare the short-term clinical effects of treatment with high-energy extracorporeal shock wave therapy vs femoral head core decompression. The postoperative visual analog scale score decreased significantly more in the extracorporeal shock wave therapy group compared with the femoral head core decompression group (P<.05). For unilateral lesions, postoperative Harris Hip Scores for all hips in the extracorporeal shock wave therapy group were more significantly improved than Harris Hip Scores for all hips in the femoral head core decompression group (P<.05). Patients who underwent extracorporeal shock wave therapy also resumed daily activities significantly earlier. Average overall operative time was similar in both groups. Symptoms disappeared significantly sooner in the extracorporeal shock wave therapy group in patients with both unilateral (P<.01) and bilateral lesions (P<.05). Hospital costs were significantly lower with extracorporeal shock wave therapy compared with femoral head core decompression. The intraoperative fluoroscopy radiation dose was lower in extracorporeal shock wave therapy than in femoral head core decompression for both unilateral (P<.05) and bilateral lesions (P<.01). On magnetic resonance imaging (MRI), bone marrow edema improved in all patients during the follow-up period. After extracorporeal shock wave therapy, all patients remained pain-free and had normal findings on posttreatment radiographs and MRI scans. Extracorporeal shock wave therapy appears to be a valid, reliable, and noninvasive tool for rapidly resolving intractable bone marrow edema syndrome of the hip, and it has a low complication rate and relatively low cost compared with other conservative and surgical treatment approaches. Copyright 2015, SLACK Incorporated.
Periacetabular Osteotomy Provides Higher Survivorship Than Rim Trimming for Acetabular Retroversion.
Zurmühle, Corinne A; Anwander, Helen; Albers, Christoph E; Hanke, Markus S; Steppacher, Simon D; Siebenrock, Klaus A; Tannast, Moritz
2017-04-01
Acetabular retroversion can cause impaction-type femoroacetabular impingement leading to hip pain and osteoarthritis. It can be treated by anteverting periacetabular osteotomy (PAO) or acetabular rim trimming with refixation of the labrum. There is increasing evidence that acetabular retroversion is a rotational abnormality of the entire hemipelvis and not a focal overgrowth of the anterior acetabular wall, which favors an anteverting PAO. However, it is unknown if this larger procedure would be beneficial in terms of survivorship and Merle d'Aubigné scores in a midterm followup compared with rim trimming. We asked if anteverting PAO results in increased survivorship of the hip compared with rim trimming through a surgical hip dislocation in patients with symptomatic acetabular retroversion. We performed a retrospective, comparative study evaluating the midterm survivorship of two matched patient groups with symptomatic acetabular retroversion undergoing either anteverting PAO or acetabular rim trimming through a surgical hip dislocation. Acetabular retroversion was defined by a concomitantly present positive crossover, posterior wall, and ischial spine sign. A total of 279 hips underwent a surgical intervention for acetabular retroversion at our center between 1997 and 2012 (166 periacetabular osteotomies, 113 rim trimmings through surgical hip dislocation). A total of 99 patients (60%) were excluded from the PAO group and 56 patients (50%) from the rim trimming group because they had any of several prespecified conditions (eg, dysplasia or pediatric conditions 61 [37%] for the PAO group and two [2%] for the rim trimming group), matching (10 [6%]/10 [9%] hips), deficient records (10 [6%]/13 [12%] hips), or the patient declined or was lost to followup (18 [11%]/31 [27%] hips). This left 67 hips (57 patients) that underwent anteverting PAO and 57 hips (52 patients) that had acetabular rim trimming. The two groups did not differ in terms of age, sex, body mass index, preoperative ROM, preoperative Merle d'Aubigné-Postel score, radiographic morphology of the acetabulum (except total and anterior acetabular coverage), alpha angle, Tönnis grade of osteoarthritis, and labral and chondral lesions on the preoperative MRI. During the period in question, we generally performed PAO from 1997 to 2003. With the availability of surgical hip dislocation and labral refixation, we generally performed rim trimming from 2004 to 2010. With growing knowledge of the underlying pathomorphology, anteverting PAOs became more common again around 2007 to 2008. A minimum followup of 2 years was required for this study. Failures were included at any time. The median followup for the anteverting PAO group was 9.5 years (range, 2-17.4 years) and 6.8 years (range, 2.2-10.5 years) for the rim trimming group (p < 0.001). Kaplan-Meier survivorship analysis was performed using the following endpoints at 5 and 10 years: THA, radiographic progression of osteoarthritis by one Tönnis grade, and/or Merle d'Aubigné-Postel score < 15 points. Although the 5-year survivorship of the two groups was not different with the numbers available (86% [95% confidence interval {CI}, 76%-94%] for anteverting PAO versus 86% [95% CI, 76%-96%] for acetabular rim trimming), we found increased survivorship at 10 years in hips undergoing anteverting PAO for acetabular retroversion (79% [95% CI, 68%-90%]) compared with acetabular rim trimming (23% [95% CI, 6%-40%]) at 10 years (p < 0.001). The drop in the survivorship curve for the acetabular rim trimming through surgical hip dislocation group started at Year 6. The main reason for failure was a decreased Merle d'Aubigné score. Anteverting PAO may be the more appropriate treatment for hips with substantial acetabular retroversion. This may be the result of reduction of an already smaller lunate surface of hips with acetabular retroversion through rim trimming. However, rim trimming may still benefit hips with acetabular retroversion in which only one or two of the three signs are positive. Future randomized studies should compare these treatments. Level III, therapeutic study.
Ipsilateral hip abductor weakness after inversion ankle sprain.
Friel, Karen; McLean, Nancy; Myers, Christine; Caceres, Maria
2006-01-01
Hip stability and strength are important for proper gait mechanics and foot position during heel strike. To determine the relationships between hip muscle strength and chronic ankle sprains and hip muscle strength and ankle range of motion. Ex post facto design with the uninvolved limb serving as the control. Laboratory. A total of 23 subjects with unilateral chronic ankle sprain were recruited. Subjects had at least 2 ipsilateral ankle sprains and were bearing full weight, with the most recent injury occurring at least 3 months earlier. They were not undergoing formal or informal rehabilitation at the time of the study. We obtained goniometric measurements for all planes of motion at the ankle. Handheld dynamometry was used to assess the strength of the hip abductor and hip extensor muscles in both limbs. Hip abductor muscle strength and plantar flexion were significantly less on the involved side than the uninvolved side (P < .001 in each case). Strength of the involved hip abductor and hip extensor muscles was significantly correlated (r = 0.539, P < .01). No significant difference was noted in hip extensor muscle strength between sides (P = .19). Our subjects with unilateral chronic ankle sprains had weaker hip abduction strength and less plantar-flexion range of motion on the involved sides. Clinicians should consider exercises to increase hip abduction strength when developing rehabilitation programs for patients with ankle sprains.
Kieser, David C; Ailabouni, Ramez; Kieser, Sandra C J; Wyatt, Michael C; Armour, Paul C; Coates, Mark H; Hooper, Gary J
2018-05-01
Custom 3D-printed acetabular implants are a new technology used in hip surgery with ever-increasing frequency. They offer patient-specific implants to optimise filling of bone defects and implant-bone contact, without the need for excessive bone resection. This is a retrospective cohort study of 46 consecutive patients who underwent an Ossis unilateral custom 3D-printed acetabular implant. Clinical (Oxford Hip Score OHS-60), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Harris Hip Score (HHS) and radiological (restoration of biomechanical hip centre, osteointegration, wear, heterotrophic ossification) results were assessed. Patient mean age was 68 years and follow-up was 38 months (minimum 24 months). 10 patients were excluded from the outcome analysis; 2 patients died, 1 required revision for deep infection and 7 were lost to follow-up. Of the 36 patients included, 21 had severe osteolysis. 7 were revised for infection, 3 for tumoural defects, 3 for metallosis, 1 for dysplasia and 1 for trauma (Paprosky 2a [n=6], 2b [n=2], 2c [n=5], 3a [n=6], 3b [n=11], pelvic dissociation [n=6]). OHS significantly improved postoperatively (16-8-48.4 p=0.027). Postoperative functional scores were good (WOMAC 98; HHS 79). The biomechanical hip centre was restored in all patients. 1 patient had early implant migration with subsequent stabilisation. 2 patients had radiographs concerning for failure of osteointegration. 1 patient had recurrent dislocations. The mid-term results of the Ossis custom 3D-printed tri-flanged acetabular implant for the management of severe acetabular defects are encouraging. The improvement in functional scores and radiographic outcomes are comparable to similar designs. In addition, no cases have required revision for aseptic loosening.
Fessy, M H; Putman, S; Viste, A; Isida, R; Ramdane, N; Ferreira, A; Leglise, A; Rubens-Duval, B; Bonin, N; Bonnomet, F; Combes, A; Boisgard, S; Mainard, D; Leclercq, S; Migaud, H
2017-09-01
Dislocation after total hip arthroplasty (THA) is a leading reason for surgical revision. The risk factors for dislocation are controversial, particularly those related to the patient and to the surgical procedure itself. The differences in opinion on the impact of these factors stem from the fact they are often evaluated using retrospective studies or in limited patient populations. This led us to carry out a prospective case-control study on a large population to determine: 1) the risk factors for dislocation after THA, 2) the features of these dislocations, and 3) the contribution of patient-related factors and surgery-related factors. Risk factors for dislocation related to the patient and procedure can be identified using a large case-control study. A multicenter, prospective case-control study was performed between January 1 and December 31, 2013. Four patients with stable THAs were matched to each patient with a dislocated THA. This led to 566 primary THA cases being included: 128 unstable, 438 stable. The primary matching factors were sex, age, initial diagnosis, surgical approach, implantation date and type of implants (bearing size, standard or dual-mobility cup). The patients with unstable THAs were 67±12 [37-73]years old on average; there were 61 women (48%) and 67 men (52%). Hip osteoarthritis (OA) was the main reason for the THA procedure in 71% (91/128) of the unstable group. The dislocation was posterior in 84 cases and anterior in 44 cases. The dislocation occurred within 3 months of the primary surgery in 48 cases (38%), 3 to 12 months after in 23 cases (18%), 1 to 5years after in 20 cases (16%), 5 to 10years after in 17 cases (13%) and more than 10years later in 20 cases. The dislocation recurred within 6 months of the initial dislocation in 23 of the 128 cases (18%). The risk factors for instability were a high ASA score with an odds ratio (OR) of 1.93 (95% CI: 1.4-2.6), neurological disability (cognitive, motor or psychiatric disorders) with an OR of 3.9 (95% CI: 2.15-7.1), history of spinal disease (lumbar stenosis, spinal fusion, discectomy, scoliosis and injury sequelae) with an OR of 1.89 (95% CI: 1.0-3.6), unrepaired joint capsule (all approaches) with an OR of 4.1 (95% CI: 2.3-7.37), unrepaired joint capsule (posterior approach) with an OR of 6.0 (95% CI: 2.2-15.9), and cup inclination outside Lewinnek's safe zone (30°-50°) with OR of 2.4 (95% CI: 1.4-4.0). This large comparative study isolated important patient-related factors for dislocation that surgeons must be aware of. We also found evidence that implanting the cup in 30° to 50° inclination has a major impact on preventing dislocation. Level III; case-control study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Stability of the Giliberty bipolar hip: report of three cases.
Langan, P; Weiss, C A
1978-01-01
The Giliberty Bipolar Hip Prosthesis consists of an unbonded acetabular cup which snap-fits over the head of the femoral prosthesis. Because of the free movement permitted at the cup-pelvic junction as well as at the snap-fit interface, there has been a great deal of concern over the potential for dislocation. Three patients in whom this unit was implanted sustained significant skeletal trauma subsequent to surgery. None of them dislocated. In each case the prosthetic head was known to be in a relatively vertical orientation with respect to the transverse axis of the pelvis prior to the injury. In 2 of the 3 cases radiographically identifiable movement of the cup was present before and after the injury. These observations suggest that the persistently mobile, vertically positioned unbonded cup remain stable despite the stress of significant trauma. It is probable that the potential for cup movement, even where on the X-ray it appears to have stopped, acts as a safety valve in absorbing force that might otherwise dislocate the hip or cause fractures of the femur or the pelvis.
Mohta, Medha; Agarwal, Deepti; Sethi, AK
2011-01-01
Needle-through-needle combined spinal–epidural (CSE) may cause significant delay in patient positioning resulting in settling down of spinal anaesthetic and unacceptably low block level. Bilateral hip flexion has been shown to extend the spinal block by flattening lumbar lordosis. However, patients with lower limb fractures cannot flex their injured limb. This study was conducted to find out if unilateral hip flexion could extend the level of spinal anaesthesia following a prolonged CSE technique. Fifty American Society of Anesthesiologists (ASA) I/II males with unilateral femur fracture were randomly allocated to Control or Flexion groups. Needle-through-needle CSE was performed in the sitting position at L2-3 interspace and 2.6 ml 0.5% hyperbaric bupivacaine injected intrathecally. Patients were made supine 4 min after the spinal injection or later if epidural placement took longer. The Control group patients (n=25) lay supine with legs straight, whereas the Flexion group patients (n=25) had their uninjured hip and knee flexed for 5 min. Levels of sensory and motor blocks and time to epidural drug requirement were recorded. There was no significant difference in sensory levels at different time-points; maximum sensory and motor blocks; times to achieve maximum blocks; and time to epidural drug requirement in two groups. However, four patients in the Control group in contrast to none in the Flexion group required epidural drug before start of surgery. Moreover, in the Control group four patients took longer than 30 min to achieve maximum sensory block. To conclude, unilateral hip flexion did not extend the spinal anaesthetic level; however, further studies are required to explore the potential benefits of this technique. PMID:21808396
Niklasch, M; Döderlein, L; Klotz, M C; Braatz, F; Wolf, S I; Dreher, T
2015-02-01
Internal rotation gait is common among children with bilateral cerebral palsy. However, despite bilaterally increased femoral anteversion asymmetric internal rotation gait is often found. Femoral derotation osteotomy (FDO) is commonly performed bilaterally. Variable functional outcomes are reported especially in cases with mild internal hip rotation during gait and abnormal preoperative pelvic rotation. A major question is if a unilateral treatment of the more involved side in asymmetric cases leads to a comparable or even superior outcome. One hundred and nine children with spastic bilateral CP treated with FDO with pre- and 1-year postoperative 3D gait analysis were retrospectively collected. The asymmetry was calculated from the preoperative difference between both limbs in hip rotation obtained by 3D gait analysis. Twenty-eight children with asymmetry larger than 20° were selected and classified into two groups, according to whether they obtained a unilateral or bilateral FDO. Preoperative clinical examination and pre- and postoperative hip and pelvic rotation in gait analysis on the more and the less involved side did not differ significantly between both groups. Interestingly, in both groups, hip rotation did not change significantly in less-involved limbs, although intraoperative derotation averaged 25°. After unilateral FDO a significant change in pelvic rotation resulted, whereas this was not found after bilateral FDO. The results of this study suggest that unilateral FDO in children with asymmetric internal rotation gait leads to a comparable functional outcome compared to bilateral treatment. Furthermore, it was shown for the first time that considering the asymmetry has a positive effect on pelvic rotation. Copyright © 2015 Elsevier B.V. All rights reserved.
Schwabe, P; Märdian, S; Perka, C; Schaser, K-D
2016-04-01
Reconstruction/stable fixation of the acetabular columns to create an adequate periacetabular requirement for the implantation of a revision cup. Displaced/nondisplaced fractures with involvement of the posterior column. Resulting instability of the cup in an adequate bone stock situation. Periprosthetic acetabulum fractures with inadequate bone stock. Extended periacetabular defects with loss of anchorage options. Isolated periprosthetic fractures of the anterior column. Septic loosening. Dorsal approach. Dislocation of hip. Mechanical testing of inlaying acetabular cup. With unstable cup situation explantation of the cup, fracture fixation of acetabulum with dorsal double plate osteosynthesis along the posterior column. Cup revision. Hip joint reposition. Early mobilization; partial weight bearing for 12 weeks. Thrombosis prophylaxis. Clinical and radiological follow-ups. Periprosthetic acetabular fracture in 17 patients with 9 fractures after primary total hip replacement (THR), 8 after revision THR. Fractures: 12 due to trauma, 5 spontaneously; 7 anterior column fractures, 5 transverse fractures, 4 posterior column fractures, 1 two column fracture after hemiendoprosthesis. 5 type 1 fractures and 12 type 2 fractures. Operatively treated cases (10/17) received 3 reinforcement ring, 2 pedestal cup, 1 standard revision cup, cup-1 cage construct, 1 ventral plate osteosynthesis, 1 dorsal plate osteosynthesis, and 1 dorsal plate osteosynthesis plus cup revision (10-month Harris Hip Score 78 points). Radiological follow-up for 10 patients: consolidation of fractures without dislocation and a fixed acetabular cup. No revision surgeries during follow-up; 2 hip dislocations, 1 transient sciatic nerve palsy.
Zhang, Lihai; Peng, Ye; Du, Chengfei; Tang, Peifu
2014-12-01
To compare the biomechanical stability of four different kinds of percutaneous screw fixation in two types of unilateral sacroiliac joint dislocation. Finite element models of unstable Tile type B and type C pelvic ring injuries were created in this study. Modelling was based on fixation with a single S1 screw (S1-1), single S2 screw (S2-1), two S1 screws (S1-2) and a combination of a single S1 and a single S2 screw (S1–S2). The biomechanical test of two types of pelvic instability (rotational or vertical) with four types of percutaneous fixation were compared. Displacement, flexion and lateral bend (in bilateral stance) were recorded and analyzed. Maximal inferior translation (displacement) was found in the S2-1 group in type B and C dislocations which were 1.58 mm and 1.90 mm, respectively. Maximal flexion was found in the S2-1 group in type B and C dislocations which were 1.55° and 1.95°, respectively. The results show that the flexion from most significant angulation to least is S2-1, S1-1, S1-2, and S1–S2 in type B and C dislocations. All the fixations have minimal lateral bend. Our findings suggest single screw S1 fixation should be adequate fixation for a type B dislocation. For type C dislocations, one might consider a two screw construct (S1–S2) to give added biomechanical stability if clinically indicated.
Rijavec, B; Košak, R; Daniel, M; Kralj-Iglič, V; Dolinar, D
2015-01-01
In order to increase the lifetime of the total hip endoprosthesis, it is necessary to understand mechanisms leading to its failure. In this work, we address volumetric wear of the artificial cup, in particular the effect of its inclination with respect to the vertical. Volumetric wear was calculated by using mathematical models for resultant hip force, contact stress and penetration of the prosthesis head into the cup. Relevance of the dependence of volumetric wear on inclination of the cup (its abduction angle ϑA) was assessed by the results of 95 hips with implanted endoprosthesis. Geometrical parameters obtained from standard antero-posterior radiographs were taken as input data. Volumetric wear decreases with increasing cup abduction angle ϑA. The correlation within the population of 95 hips was statistically significant (P = 0.006). Large cup abduction angle minimises predicted volumetric wear but may increase the risk for dislocation of the artificial head from the cup in the one-legged stance. Cup abduction angle and direction of the resultant hip force may compensate each other to achieve optimal position of the cup with respect to wear and dislocation in the one-legged stance for a particular patient.
Hip Surveillance in Children with Cerebral Palsy.
Huser, Aaron; Mo, Michelle; Hosseinzadeh, Pooya
2018-04-01
The hip is the second most common involved joint in cerebral palsy. Hip displacement occurs in more than 33% of children with cerebral palsy, with a higher prevalence in nonambulatory children. Hip displacement in this population is typically progressive. Hip dislocation can result in pain and difficulty with sitting and perineal care. Since early stage of hip displacement can be silent, and hip surveillance programs are recommended. Most programs use the degree of hip dysplasia and Growth Motor Function Classification System level for screening recommendations. Treatment depends on the degree of dysplasia, functional status of the patient, and patient's age. Copyright © 2017 Elsevier Inc. All rights reserved.
Faucett, Scott C; Genuario, James W; Tosteson, Anna N A; Koval, Kenneth J
2010-02-01
: A previous hip fracture more than doubles the risk of a contralateral hip fracture. Pharmacologic and environmental interventions to prevent hip fracture have documented poor compliance. The purpose of this study was to examine the cost-effectiveness of prophylactic fixation of the uninjured hip to prevent contralateral hip fracture. : A Markov state-transition model was used to evaluate the cost and quality-adjusted life-years (QALYs) for unilateral fixation of hip fracture alone (including internal fixation or arthroplasty) compared with unilateral fixation and contralateral prophylactic hip fixation performed at the time of hip fracture or unilateral fixation and bilateral hip pad protection. Prophylactic fixation involved placement of a cephalomedullary nail in the uninjured hip and was initially assumed to have a relative risk of a contralateral fracture of 1%. Health states included good health, surgery-related complications requiring a second operation (infection, osteonecrosis, nonunion, and malunion), fracture of the uninjured hip, and death. The primary outcome measure was the incremental cost-effectiveness ratio estimated as cost per QALY gained in 2006 US dollars with incremental cost-effectiveness ratios below $50,000 per QALY gained considered cost-effective. Sensitivity analyses evaluated the impact of patient age, annual mortality and complication rates, intervention effectiveness, utilities, and costs on the value of prophylactic fixation. : In the baseline analysis, in a 79-year-old woman, prophylactic fixation was not found to be cost-effective (incremental cost-effectiveness ratio = $142,795/QALY). However, prophylactic fixation was found to be a cost-effective method to prevent contralateral hip fracture in: 1) women 71 to 75 years old who had 30% greater relative risk for a contralateral fracture; and 2) women younger than age 70 years. Cost-effectiveness was greater when the additional costs of prophylaxis were less than $6000. However, for most analyses, the success of prophylactic fixation was highly sensitive to the effectiveness and the relative morbidity and mortality of the additional procedure. : Prophylactic fixation with a cephalomedullary nail was not found to be cost-effective for the average older woman who sustained a hip fracture. However, it may be appropriate for select patient populations. The study supports the need for basic science and clinical trials investigating the effectiveness of prophylactic fixation for patient populations at higher lifetime risk for contralateral hip fracture.
Inoue, Daisuke; Kajino, Yoshitomo; Taga, Tadashi; Yamamoto, Takashi; Takagi, Tomoharu
2018-01-01
Traditionally, Charcot arthropathy has been considered an absolute contraindication for total hip arthroplasty (THA). However, some recent reports have shown that good short- to mid-term results can be achieved by improving the durability of the implant. This paper reports the mid- to long-term results of THA in two patients with Charcot hip joints caused by congenital insensivity to pain with anhydrosis. Both patients suffered multiple posterior dislocations in the six months immediately following surgery. However, with the continuous use of a hard abduction brace, one patient was eventually able to walk with a lofstrand cane and the other with the use of one crutch. Although one patient experienced a dislocation five years after surgery, X-rays taken after nine years and five years, respectively, revealed no clinical signs of implant loosening. We conclude that, with careful planning and appropriate precautions, THA may be a viable treatment option for Charcot hip joints caused by congenital insensivity to pain with anhydrosis. PMID:29666733
[Intra-prosthetic dislocation of the Bousquet dual mobility socket].
Lecuire, F; Benareau, I; Rubini, J; Basso, M
2004-05-01
The Bousquet system is a dual mobility head-polyethylene polyethylene-metal cup socket. The polyethylene insert retaining the femoral head moves in the noncemented metal cup, increasing both mobility and stability. Between 1989 and 1997, seven cases of intra-prosthetic dislocation (six patients) were observed. The femoral head escaped from the polyethylene insert due to wear. On the average, this complication occurred ten Years after implantation. Risk of dislocation was high in six of the seven hips. All patients had a large sized stem screwed into the femoral neck. There was a characteristic radiological aspect with loss of the concentric head metal cup configuration. The head was applied against the upper wall of the metal cup. Surgical replacement was undertaken early in six patients by simply changing the insert without modifying the other stable components. Outcome remained good at three to eight Years. One patient underwent late surgery. The insert and the cup were replaced with a classical implant. Functional outcome was good but recurrent dislocation occurred. At mid-term, intra-prosthetic dislocation of dual mobility sockets appears to be exceptional. Dislocation results from polyethylene wear leading to failure of the insert to retain the prosthetic head. Wear is favored by direct phenomena (direct contact between neck and insert which can occur early if there is a small difference in the head and neck diameters) or indirect phenomena (factors limiting polyethylene metal-cup mobility). Surgical treatment is necessary. If undertaken early, replacement with a modular head and insert can be sufficient if the prosthesis has not loosened but the metal cup may have to be replaced in the event of metal-metal contact between the head and the cup. Prosthesis loosening, wear of the metal cup, or an identified cause of dislocation imply replacing the failing implants. Implantation of the dual mobility system is particularly interesting for patients with a high risk of dislocation or a chronically unstable hip prosthesis. Careful technique is required to reduce or retard the risk of intra-prosthetic dislocation. Intra-prosthetic dislocation of a dual mobility socket is an exceptional complication at mid-term. Surgical treatment is required but may be limited to simple insert replacement. Systematic use of this type of implant in young subjects must be carefully examined, but for us, the risk of dislocation does not outweigh the advantages of this original concept of dual mobility. This type of socket remains an useful preventive technique for high-risk hips or for curative treatment of recurrent dislocation.
Early results of one-stage correction for hip instability in cerebral palsy.
Kim, Hui Taek; Jang, Jae Hoon; Ahn, Jae Min; Lee, Jong Seo; Kang, Dong Joon
2012-06-01
We evaluated the clinical and radiological results of one-stage correction for cerebral palsy patients. We reviewed clinical outcomes and radiologic indices of 32 dysplastic hips in 23 children with cerebral palsy (13 males, 10 females; mean age, 8.6 years). Ten hips had dislocation, while 22 had subluxation. Preoperative Gross Motor Function Classification System (GMFCS) scores of the patients were as follows; level V (13 patients), level IV (9), and level III (1). Acetabular deficiency was anterior in 5 hips, superolateral in 7, posterior in 11 and mixed in 9, according to 3 dimensional computed tomography. The combined surgery included open reduction of the femoral head, release of contracted muscles, femoral shortening varus derotation osteotomy and the modified Dega osteotomy. Hip range of motion, GMFCS level, acetabular index, center-edge angle and migration percentage were measured before and after surgery. The mean follow-up period was 28.1 months. Hip abduction (median, 40°), sitting comfort and GMFCS level were improved after surgery, and pain was decreased. There were two cases of femoral head avascular necrosis, but no infection, nonunion, resubluxation or redislocation. All radiologic indices showed improvement after surgery. A single event multilevel surgery including soft tissue, pelvic and femoral side correction is effective in treating spastic dislocation of the hip in cerebral palsy.
Migratory Bone Marrow Edema Syndrome of the Hips: A Case Report
Santoso, A; Ingale, PS; Park, KS
2017-01-01
Migratory bone marrow edema syndrome (BMES) of the hip is a rare entity. We report the case of a 41-year old male with migratory BMES of the hip with eight months interval period between onset of the pain and consultation. This patient was successfully treated non-surgically. It is important to always inform the patient with unilateral BMES of the hip regarding the possibility of future involvement of the contralateral hip. PMID:29326770
Ipsilateral Hip Abductor Weakness After Inversion Ankle Sprain
Friel, Karen; McLean, Nancy; Myers, Christine; Caceres, Maria
2006-01-01
Context: Hip stability and strength are important for proper gait mechanics and foot position during heel strike. Objective: To determine the relationships between hip muscle strength and chronic ankle sprains and hip muscle strength and ankle range of motion. Design: Ex post facto design with the uninvolved limb serving as the control. Setting: Laboratory. Patients or Other Participants: A total of 23 subjects with unilateral chronic ankle sprain were recruited. Subjects had at least 2 ipsilateral ankle sprains and were bearing full weight, with the most recent injury occurring at least 3 months earlier. They were not undergoing formal or informal rehabilitation at the time of the study. Main Outcome Measure(s): We obtained goniometric measurements for all planes of motion at the ankle. Handheld dynamometry was used to assess the strength of the hip abductor and hip extensor muscles in both limbs. Results: Hip abductor muscle strength and plantar flexion were significantly less on the involved side than the uninvolved side (P < .001 in each case). Strength of the involved hip abductor and hip extensor muscles was significantly correlated (r = 0.539, P < .01). No significant difference was noted in hip extensor muscle strength between sides (P = .19). Conclusions: Our subjects with unilateral chronic ankle sprains had weaker hip abduction strength and less plantar-flexion range of motion on the involved sides. Clinicians should consider exercises to increase hip abduction strength when developing rehabilitation programs for patients with ankle sprains. PMID:16619098
Tomaru, Yohei; Yoshioka, Tomokazu; Sugaya, Hisashi; Aoto, Katsuya; Wada, Hiroshi; Akaogi, Hiroshi; Yamazaki, Masashi; Mishima, Hajime
2017-07-06
We had previously established concentrated autologous bone marrow aspirate transplantation (CABMAT), a one-step, low-invasive, joint-preserving surgical technique for treating osteonecrosis of the femoral head (ONFH). The present study aimed to evaluate the effects of CABMAT as a hip preserving surgical approach, preventing femoral head collapse in asymptomatic ONFH. In total, 222 patients (341 hips) with ONFH were treated with CABMAT between April 2003 and March 2013. Based on magnetic resonance imaging, we determined that 119 of these patients had bilateral asymptomatic ONFH (238 hips), and 38 further patients had unilateral asymptomatic ONFH (38 hips). In this series, we retrospectively examined 31 hips in 31 patients with unilateral asymptomatic ONFH treated surgically between 2003 and 2012 and followed up for more than 2 years. Clinical and radiological evaluation were performed immediately before the procedure and at the final follow-up. The two-year follow-up rate among patients with unilateral ONFH was 82% (31/38). Therefore, the present study included 31 patients (19 males and 12 females), with a mean age and follow-up period of 40 and 5.8 years, respectively. Of the 31 asymptomatic hips, 5, 6, 10, and 10 had osteonecrosis of types A, B, C1, and C2, respectively. The diagnosis, classification, and staging of ONFH were based on the 2001 Japanese Orthopaedic Association (JOA) classification. Secondary collapse of the femoral head was observed in 6/10 hips and 5/10 hips with osteonecrosis of types C1 and C2, respectively. Total hip arthroplasty was performed in 9.6% of patients (3/31 hips), at an average of 33 months after surgery. Clinical symptoms improved after surgery, and the secondary collapse rate at a mean of 5.8 years after CABMAT was lower than that reported in several previous studies on the natural course of asymptomatic ONFH. Early diagnosis of ONFH (i.e., before femoral head collapse) and early intervention with CABMAT could improve the clinical outcome of corticosteroid and alcohol-induced ONFH.
Complete dislocation of the ulnar nerve at the elbow: a protective effect against neuropathy?
Leis, A Arturo; Smith, Benn E; Kosiorek, Heidi E; Omejec, Gregor; Podnar, Simon
2017-08-01
Recurrent complete ulnar nerve dislocation has been perceived as a risk factor for development of ulnar neuropathy at the elbow (UNE). However, the role of dislocation in the pathogenesis of UNE remains uncertain. We studied 133 patients with complete ulnar nerve dislocation to determine whether this condition is a risk factor for UNE. In all, the nerve was palpated as it rolled over the medial epicondyle during elbow flexion. Of 56 elbows with unilateral dislocation, UNE localized contralaterally in 17 elbows (30.4%) and ipsilaterally in 10 elbows (17.9%). Of 154 elbows with bilateral dislocation, 26 had UNE (16.9%). Complete dislocation decreased the odds of having UNE by 44% (odds ratio = 0.475; P = 0.028), and was associated with less severe UNE (P = 0.045). UNE occurs less frequently and is less severe on the side of complete dislocation. Complete dislocation may have a protective effect on the ulnar nerve. Muscle Nerve 56: 242-246, 2017. © 2016 Wiley Periodicals, Inc.
Li, Ya-Min; Li, Jue-Hong; Li, Bin; Wang, Jia-Xing; Chen, Yun-Su
2016-01-01
Objectives To investigate whether adult patients with unilateral developmental dysplasia of the hip (UDDH) have pelvic asymmetry and what correlation existing between them. Methods A total of 100 adult patients with UDDH were enrolled in the retrospective observational study in Shanghai Jiaotong University Affiliated Sixth People’s Hospital, Shanghai, China, between January 2012 and February 2014. The anteroposterior pelvic radiographs were reviewed and the pelvic heights and ischium heights were measured and compared between the affected and non-affected sides to find out the relationship between the pelvic morphology and hip dysplasia. Results The pelvic heights demonstrated significant differences between the non-affected side and the affected side in patients with Crowe type II-IV UDDH (p<0.05), but not in patients with Crowe type I UDDH (p=0.09). There were significant differences in the bilateral ischium heights in patients with Crowe type III and IV UDDH (p<0.05), but not in patients with Crowe type I and II UDDH (p=0.78, p=0.055). In addition, the degree of hip dysplasia was positively associated with the degrees of asymmetry of pelvis (r=0.78, p<0.001) and ischium (r=0.72, p<0.001) in UDDH patients. Conclusion The pelvic asymmetry exists in adult patients with UDDH. In addition, the degree of asymmetry has correlation with the degree of hip dysplasia. We recommend that it should be taken more cautions to use teardrops and ischial tuberosity as anatomy landmarks to balance leg-length discrepancy for unilateral DDH patients in preoperative planning and total hip arthroplasty. PMID:27874150
[New classification of Crowe type IV developmental dysplasia of the hip].
Ma, Hai-yang; Zhou, Yong-gang; Zheng, Chong; Cao, Wen-zhe; Wang Sen; Wu, Wen-ming; Piao, Shang; Du, Yin-qiao
2016-02-01
To compare differences between Crowe IV developmental dysplasia of the hip (DDH) with secondary acetabulum and Crowe IV DDH without secondary acetabulum,and determine whether it is necessary to divide Crowe IV DDH into two subtypes. From June 2007 to May 2015,145 hips of 112 Crowe N patients who underwent total hip arthroplasty (THA) using S-ROM stem were divided into two groups: secondary acetabulum formaton group (group A) and no secondary acetabulum formaton group (group B). In group A,there were 12 females, 96 males,with an average age of (39.38 ± 11.19) years old. In group B, there were 2 females, 35 males, with an average age of (38.19 ± 10.92) years old. All the patients were evaluated by using Harris Hip Score. Radiographic evaluations were made preoperatively and during follow up. The differences between two groups were compared on dislocation height, canal flare index (CFI), subtrochanteric shortening osteotomy (SSTO) usage, pre- and post-operation Harris scores, complications. The dislocation height for group A was (4.74 ± 1.57) cm, while the dislocation height for group B was (3.12 ± 1.15) cm. Significantly difference was detected between two groups. The CFI for group A was 2.69 ± 0.68, while the CFI for group B was 3.42 ± 0.79, and the significantly difference was detected between two groups. Harris scores were totally improved from 58.18 ± 15.67 preoperatively to 91.20 ± 3.79 post-operatively and the difference was significant. Pre-operative Harris scores was 58.1 ± 15.3 in group A, 58.3 ± 16.9 in group B. Post-operative Harris scores was 91.0 ± 4.1 in group A, 91.0 ± 5.1 in group B. No significant difference was found on Harris scores between A and B preoperatively and post-operatively. Complications of 4 cases peri-prosthesis fracture, 4 cases dislocation and 4 cases nerve injury occur in group A; While only one case dislocation and one case nerve injury occur in group B. No statistical significance was detected. Crowe IV DDH with secondary acetabulum is significantly different from Crowe IV DDH without secondary acetabulum on dislocation height and femoral morphology, which causes the different selections of surgical techniques (SSTO usage or not). These important differences in fundamental parameters indicate the necessity to further divide Crowe IV DDH into IVA and IVB two subtypes.
Bhatti, Anisuddin; Jamali, A R; Mehboob, Ghulam
2009-01-01
This study was conducted to assess the effect of age on the ultimate outcome measures following single stage surgical procedure of soft tissue release, relocation, capsulorrhaphy, femoral shortening with varus/derotation osteotomy and pelvic osteotomy. A case series. The study with two groups of pretest-posttest design was conducted at Department of Orthopaedic Surgery, Jinnah Postgraduate Medical Centre (JPMC), Karachi, from 1993 to January 2008. Patients included were having neglected, congenital dislocation of the hip joint, aged over 3 years. Patients with failed previous surgery, paralytic, teratological, traumatic or septic dislocations and patients with less than 5 years follow-up were excluded from the study. The patients were divided into two groups, 3-7 years (37 hip joints) and over 7 years (13 hip joints). The single stage surgical procedure of open relocation, femoral shortening/derotation/ varus osteotomy and pelvic osteotomy was the dependent variable; whereas, the final clinico-radiological results based upon Tonnis grading, Severin's clinical/radiological grading, Klisic's overall rating and acetabular index were the independent variables of the study. Pre- and postoperative data was assessed for overall improvement and the difference in outcome measures between the two age groups. Significant overall improvement on all parameters was achieved after surgery. When results were compared between two age groups, there was no significant difference in the final outcome as per Tonnis grading and Severin's clinical typing as modified by Gibson (97.3% versus 84.4% normal hip joints or Tonnis grade 1 and 78.37% versus 53.85% Severin's type 1) but the results based upon Severin's radiological grading (62.16% versus 15.38%) and Klisic's overall rating (62.16% versus 15.38%) were significantly better in 3-7 years as compared to those over 7 years. There was no significant difference between the two age groups when compared for improvement in acetabular index. On further analysis, a progressive deterioration of results with increasing age was observed, yet the results in those aged over 7 years were reasonably justified surgical correction of congenital dislocation of the hip joint. Majority of the complications were seen in children operated at the age of 4-5 years. There were 7 cases (14%) of redislocation/subluxation and 6 were in 3-7 years age group. There were 4 cases (8%) of the avascular necrosis of the femoral head. Three patients had residual coxa vara and 2 had significant limb shortening. Limb lengthening was done in these 2 cases. The final results displayed progressive deterioration of clinical, radiological and functional outcome measures with aging after single stage reconstructive surgery for the congenital dislocation of hip joint. However, despite this, the results in children over 7 years were also good/excellent in most of the cases justifying surgery.
Gekeler, Jörg
2007-10-01
AIMS OF DIAGNOSTIC RADIOGRAPHY: Visualization of the proximal femur in two clearly defined projections. Radiologic and morphological diagnosis of slipped capital femoral epiphysis. Evaluation of the stability of the femoral epiphysis: chronic slippage or acute interruption of continuity between the femoral epiphysis and the femoral neck metaphysis. Radiometric measurement of the spatial deformity of the femoral epiphysis. Measurement of the projected epiphyseal angle on the radiograph as the basis for possible conversion into anatomically correct angles at the proximal femur. Preoperative planning of therapeutic surgical procedures. Idiopathic hip pain in the growing child or adolescent. Referred pain to the knee or thigh. Unusual gait pattern with external rotation deformity of the leg, limping that favors one leg or limping due to leg length discrepancy. Abnormal sonography, CT or MRI findings. Eventful history including minor injury or genuine trauma. Symptoms and uncommon physical constitution: obesity, exceptional longitudinal growth of the extremities, and absence of secondary sex characteristics. Indications for Radiographic Imaging of the Hip Joint in Two Planes None. Standard positioning of the patient or the affected extremity. First standard radiograph: proximal femur in anteroposterior projection. Position of the leg with the patella directed anteriorly. Contraction of the external rotators at the hip joint is compensated by elevation of the hip until the leg is in the neutral position. Second standard radiograph: axial view of the proximal femur in anteroposterior projection. Leg flexed to 90 degrees at the hip and in 45 degrees abduction. Thigh position parallel to the longitudinal axis of the table (zero rotation). Early signs of incipient or imminent femoral epiphyseolysis: --Disintegration, widening and blurred margins of the epiphyseal plate. --Increasing loss of height of the femoral epiphysis due to incipient dislocation. --The tangent to the lateral femoral neck intersects only slightly with the femoral head or runs tangential to the epiphysis. --Important second radiograph in axial projection: incipient slippage is seen early here. Comparison with the contralateral side. Chronic slipped capital femoral epiphysis in adolescents: --Advanced epiphyseal dislocation visible in both planes. The tangent to the lateral femoral neck no longer intersects with the dislocated femoral epiphysis. In some cases, varus deformity of the femoral neck and periosteal elevation at the borders of the medial femoral neck. --Epiphyseal dislocation even more apparent in the axial view. Acute slipped capital femoral epiphysis in adolescents: --Complete interruption of continuity between epiphysis and metaphysis. --Widened gap between epiphysis and metaphysis. --Cystic irregularities of the metaphysis. --In most cases, substantial dislocation between epiphysis and metaphysis. --"Acute on chronic slip": specific type of acute epiphyseal dislocation subsequent to chronic epiphyseolysis. In addition to signs of acute separation, secondary symptoms of chronic epiphyseolysis such as femoral neck arcuation and spur formation at the head-neck junction. --Dynamic fluoroscopy may be indicated to confirm acute dislocation. Defined axes are marked on the radiograph: anatomic axis of the femur, femoral neck axis, and so-called epiphyseal axis (perpendicular to the base of the epiphysis). Measurement of the projected epiphysis-diaphysis angle (ED' angle) on the anteroposterior radiograph and the projected epiphyseal torsion angle (ET' angle) on the axial radiograph. For slight to moderate slippage, the difference between the epiphyseal dislocation angle obtained from the radiographs (as projected in two planes) compared with the anatomic, i.e., real dislocation angle at the proximal femur is generally relatively minor. Conversion of the projected angle to the real angle is not essential in these cases (if in doubt, see Table 1). For more severe dislocations, the differences between the projected and real angles are far more apparent. Table 1 facilitates conversion of the epiphyseal dislocation angles taken from the radiograph into anatomically correct dislocation angles at the proximal femur. Conversion to real angles, especially for preoperative planning of complex corrective surgery, is indicated for more severe deformities of the femoral epiphysis. Conversion into real (anatomic) angles is indicated for exact prognostic evaluation of prearthrotic deformities.
Eight indicators of unilateral pregnancy.
Melchionne, Kevin
2010-12-01
Unintended pregnancy often leads to undesirable outcomes for both mothers and children. However, the definition of unintended pregnancy in the sociology of family formation has been restricted to the intentions of mothers. The intentions of fathers--and, with them, the possible role of disagreement about pregnancy intention--remain outside most conceptual frameworks and research programs. This article draws together a number of indicators of unilateral pregnancy in research on contemporary family formation in the United States. Studies of pregnancy intendedness and contraceptive use consistently provide evidence suggesting a significant role for unilateral pregnancy in family formation. Working on the assumption that unilateral pregnancy presents great potential for social dislocation, this article argues for the integration of the concept of unilateral pregnancy into the theoretical framework informing research on family formation.
Bedi, Asheesh; Zaltz, Ira; De La Torre, Katrina; Kelly, Bryan T
2011-07-01
Whether open or arthroscopic techniques are employed, the goal of femoroacetabular impingement (FAI) surgery is to achieve impingement-free range of motion. While arthroscopic approaches have improved and gained popularity, an objective evaluation of the surgical correction achieved with this approach compared with open surgery remains to be defined in the literature. This study was undertaken to compare the efficacy of arthroscopic osteoplasty and open surgical dislocation in treating FAI dysmorphology in a consecutive series of patients. Cohort study; Level of evidence, 3. Surgical treatment was performed in 60 male patients under 40 years of age for symptomatic FAI refractory to nonoperative management. Patients were matched (not randomized) to treatment groups: 30 patients (15 left and 15 right hips) underwent arthroscopic cam and/or rim osteoplasty with labral debridement and/or refixation by an arthroscopic surgeon; and 30 (14 left and 16 right hips) underwent open surgical dislocation, cam and/or rim osteoplasty, and labral debridement or refixation by a hip preservation surgeon. Anteroposterior (AP) pelvis and extended-neck (Dunn) lateral radiographs were obtained and the depth of resection and arc of resection were measured by assessment of anterior femoral head-neck offset, AP and lateral α angle, and β angle on preoperative and postoperative radiographs. In the arthroscopic group, the extended-neck lateral α angle was reduced by a mean of 17.2° (28.3%, P < .05), AP α angle was reduced by a mean of 12.6° (16.8%), anterior head-neck offset improved 5.0 mm (111%, P < .05), and β angle increased by a mean of 23.1°. In the open dislocation group, the extended-neck lateral α angle was reduced by a mean of 21.2° (30.7%, P < .05), AP α angle was reduced by a mean of 20.1° (25.7%), anterior head-neck offset improved 6.56 mm (108%, P < .05), and β angle increased by a mean of 18.35°. Arthroscopic osteoplasty can restore head-neck offset and achieve similar depth, arc, and proximal-distal resection with comparable efficacy to open surgical dislocation for anterior and anterosuperior cam and focal rim impingement deformity. The open technique, however, may allow greater correction of posterosuperior loss of femoral offset and may be favorable for FAI patterns that demonstrate considerable proximal femoral deformity on AP radiographs.
Epinette, Jean-Alain; Harwin, Steven F; Rowan, Fiachra E; Tracol, Philippe; Mont, Michael A; Chughtai, Morad; Westrich, Geoffrey H
2017-03-01
To evaluate early performance of contemporary dual mobility acetabular systems with second generation annealed highly cross-linked polyethylene for primary hip arthroplasty of patients under 55 years of age. A prospective observational five years study across five centers in Europe and the USA of 321 patients with a mean age of 48.1 years was performed. Patients were assessed for causes of revision, hip instability, intra-prosthetic dissociation, Harris hip score and radiological signs of osteolysis. There were no dislocations and no intra-prosthetic dissociations. Kaplan Meier analysis demonstrated 97.51% survivorship for all cause revision and 99.68% survivorship for acetabular component revision at five years. Mean Harris hip score was 93.6. Two acetabular shells were revised for neck-rim implant impingement without dislocation and ten femoral stems were revised for causes unrelated to dual mobility implants. Contemporary highly cross-linked polyethylene dual mobility systems demonstrate excellent early clinical, radiological, and survivorship results in a cohort of patients that demand high performance from their implants. It is envisaged that DM and second generation annealed HXLPE may reduce THA instability and wear, the two most common causes of THA revision in hip arthroplasty.
Molina-Rueda, Francisco; Alguacil-Diego, Isabel M.; Cuesta-Gómez, Alicia; Iglesias-Giménez, Javier; Martín-Vivaldi, Andrés; Miangolarra-Page, Juan C.
2014-01-01
Background: Lower limb amputees exhibit postural control deficits during standing which can affect their walking ability. Objectives: The primary purpose of the present study was to analyze the thorax, pelvis, and hip kinematics and the hip internal moment in the frontal plane during gait in subjects with Unilateral Transtibial Amputation (UTA). Method: The participants included 25 people with UTA and 25 non-amputees as control subjects. Gait analysis was performed using the Vicon(r) Motion System. We analyzed the motion of the thorax, pelvis, and hip (kinematics) as well as the hip internal moment in the frontal plane. Results: The second peak of the hip abductor moment was significantly lower on the prosthetic side than on the sound side (p=.01) and the control side (right: p=.01; left: p=.01). During middle stance, the opposite side of the pelvis was higher on the prosthetic side compared to the control side (right: p=.01: left: p=.01). Conclusions: The joint internal moment at the hip in the frontal plane was lower on the prosthetic side than on the sound side or the control side. Thorax and pelvis kinematics were altered during the stance phase on the prosthetic side, presumably because there are mechanisms which affect postural control during walking. PMID:25003278
Fousek, J; Indráková, P
2007-02-01
The aim of the study was a retrospective evaluation of our patients with post-dysplastic hips treated by cemented or non-cemented total hip arthroplasty (THA) in order to ascertain which type and position of the acetabular component was most effective. In the years 1999-2002, 111 THA procedures were performed in 93 patients, 76 women and 17 men, with post-dysplastic hip arthritis. The average age of the patients at the time of implantation was 52.6 years. On the basis of pre-operative radiographic findings, the patients' conditions were evaluated using the Hartofilakidis classification into three disease categories: dysplasia, low dislocation and high dislocation, and the patients were placed in two groups. Group 1 included 78 patients, and group 2 comprised 26 patients. None of our patients was classified as having high dislocation. Thirty-nine of these patients had previously undergone surgery for dysplastic hips. A total of 104 THAs were evaluated, because radiographic data was incomplete in seven cases. In addition to X-ray findings, the prosthesis type (cemented, hybrid, non-cemented), post-operative complications and signs of loosening were included in the evaluation. Clinical outcomes were assessed by the Harris score. The follow-up terminating on 31st December 2005 was 67 months on the average. In group 1 patients, the average Harris score increased from 38.6 to 80.3 points and in group 2 patients from 35.5 to 84.9 points, mostly with excellent and good results. In 72.1 % of the hips, a press-fit acetabular component was implanted. In 55.8 % of the cases, the acetabular component was implanted off the anatomical center of rotation, into the high hip center, with the range from 9 to 20 mm and an average of 15 mm. The average limb lengthening was 2.5 cm, ranging from 1.0 to 3.5 cm. Our results show that it is more effective to use non-cemented THA for post-dysplastic hips. The implantation of a noncemented acetabular component into the high center provides better covering of the cup with solid bone, without the necessity of cotyloplasty or structural graft use. Also, it does not markedly affect hip function or patients' subjective feelings.
Gender comparisons between unilateral and bilateral landings.
Weinhandl, Joshua T; Joshi, Mukta; O'Connor, Kristian M
2010-11-01
The increased number of women participating in sports has led to a higher knee injury rate in women compared with men. Among these injuries, those occurring to the ACL are commonly observed during landing maneuvers. The purpose of this study was to determine gender differences in landing strategies during unilateral and bilateral landings. Sixteen male and 17 female recreational athletes were recruited to perform unilateral and bilateral landings from a raised platform, scaled to match their individual jumping abilities. Three-dimensional kinematics and kinetics of the dominant leg were calculated during the landing phase and reported as initial ground contact angle, ranges of motion (ROM) and peak moments. Lower extremity energy absorption was also calculated for the duration of the landing phase. Results showed that gender differences were only observed in sagittal plane hip and knee ROM, potentially due to the use of a relative drop height versus the commonly used absolute drop height. Unilateral landings were characterized by significant differences in hip and knee kinematics that have been linked to increased injury risk and would best be classified as "stiff" landings. The ankle musculature was used more for impact absorption during unilateral landing, which required increased joint extension at touchdown and may increase injury risk during an unbalanced landing. In addition, there was only an 11% increase in total energy absorption during unilateral landings, suggesting that there was a substantial amount of passive energy transfer during unilateral landings.
Hussey, Daniel K; Madanat, Rami; Donahue, Gabrielle S; Rolfson, Ola; Muratoglu, Orhun K; Malchau, Henrik
2016-01-01
Background and purpose Blood metal ion levels can be an indicator for detecting implant failure in metal-on-metal (MoM) hip arthroplasties. Little is known about the effect of bilateral MoM implants on metal ion levels and patient-reported outcomes. We compared unilateral patients and bilateral patients with either an ASR hip resurfacing (HR) or an ASR XL total hip replacement (THR) and investigated whether cobalt or chromium was associated with a broad spectrum of patient outcomes. Patients and methods From a registry of 1,328 patients enrolled in a multicenter prospective follow-up of the ASR Hip System, which was recalled in 2010, we analyzed data from 659 patients (311 HR, 348 THR) who met our inclusion criteria. Cobalt and chromium blood metal ion levels were measured and a 21-item patient-reported outcome measures (PROMs) questionnaire was used mean 6 years after index surgery. Results Using a minimal threshold of ≥7 ppb, elevated chromium ion levels were found to be associated with worse health-related quality of life (HRQoL) (p < 0.05) and hip function (p < 0.05) in women. These associations were not observed in men. Patients with a unilateral ASR HR had lower levels of cobalt ions than bilateral ASR HR patients (p < 0.001) but similar levels of chromium ions (p = 0.09). Unilateral ASR XL THR patients had lower chromium and cobalt ion levels (p < 0.005) than bilateral ASR XL THR patients. Interpretation Chromium ion levels of ≥7 ppb were associated with reduced functional outcomes in female MoM patients. PMID:27459602
Li, Ya-Min; Li, Jue-Hong; Li, Bin; Wang, Jia-Xing; Chen, Yun-Su
2016-12-01
To investigate whether adult patients with unilateral developmental dysplasia of the hip (UDDH) have pelvic asymmetry and what correlation existing between them. Methods: A total of 100 adult patients with UDDH were enrolled in the retrospective observational study in Shanghai Jiaotong University Affiliated Sixth People's Hospital, Shanghai, China, between January 2012 and February 2014. The anteroposterior pelvic radiographs were reviewed and the pelvic heights and ischium heights were measured and compared between the affected and non-affected sides to find out the relationship between the pelvic morphology and hip dysplasia. Results: The pelvic heights demonstrated significant differences between the non-affected side and the affected side in patients with Crowe type II-IV UDDH (p less than 0.05), but not in patients with Crowe type I UDDH (p=0.09). There were significant differences in the bilateral ischium heights in patients with Crowe type III and IV UDDH (p less than 0.05), but not in patients with Crowe type I and II UDDH (p=0.78, p=0.055). In addition, the degree of hip dysplasia was positively associated with the degrees of asymmetry of pelvis (r=0.78, p less than 0.001) and ischium (r=0.72, p less than 0.001) in UDDH patients. Conclusion: The pelvic asymmetry exists in adult patients with UDDH. In addition, the degree of asymmetry has correlation with the degree of hip dysplasia. We recommend that it should be taken more cautions to use teardrops and ischial tuberosity as anatomy landmarks to balance leg-length discrepancy for unilateral DDH patients in preoperative planning and total hip arthroplasty.
Gallart, X; Gomez, J C; Fernández-Valencia, J A; Combalía, A; Bori, G; García, S; Rios, J; Riba, J
2014-01-01
To evaluate the short-term results of an ultra high molecular weight polyethylene retentive cup in patients at high risk of dislocation, either primary or revision surgery. Retrospective review of 38 cases in order to determine the rate of survival and failure analysis of a constrained cemented cup, with a mean follow-up of 27 months. We studied demographic data, complications, especially re-dislocations of the prosthesis and, also the likely causes of system failure analyzed. In 21.05% (8 cases) were primary surgery and 78.95% were revision surgery (30 cases). The overall survival rate by Kaplan-Meier method was 70.7 months. During follow-up 3 patients died due to causes unrelated to surgery and 2 infections occurred. 12 hips had at least two previous surgeries done. It wasn't any case of aseptic loosening. Four patients presented dislocation, all with a 22 mm head (P=.008). Our statistical analysis didn't found relationship between the abduction cup angle and implant failure (P=.22). The ultra high molecular weight polyethylene retentive cup evaluated in this series has provided satisfactory short-term results in hip arthroplasty patients at high risk of dislocation. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.
Open and Arthroscopic Surgical Treatment of Femoroacetabular Impingement
Kuhns, Benjamin D.; Frank, Rachel M.; Pulido, Luis
2015-01-01
Femoroacetabular impingement (FAI) is a common cause of hip pain, and when indicated, can be successfully managed through open surgery or hip arthroscopy. The goal of this review is to describe the different approaches to the surgical treatment of FAI. We present the indications, surgical technique, rehabilitation, and complications associated with (1) open hip dislocation, (2) reverse periacetabular osteotomy, (3) the direct anterior “mini-open” approach, and (4) arthroscopic surgery for FAI. PMID:26697431
Bauer, Stefan; Dunne, Ben; Whitewood, Colin
2012-01-01
Bilateral simultaneous elbow dislocations are extremely rare and have only been described in 12 cases. In the paediatric population unilateral elbow dislocations are rare with 3–6% of all elbow injuries and there are only few studies describing this injury exclusively in children. There is only one case report of a paediatric patient who sustained a simultaneous bilateral elbow dislocation with medial epicondyle fractures. We present a second paediatric case of simultaneous bilateral elbow dislocation with associated displaced bilateral medial epicondyle fractures in a gymnast with joint hyperlaxity (3 of 5 Wynne-Davies criteria) treated with closed reduction and short-term immobilisation (3 weeks). The patient returned to full trampoline gymnastics between 4 and 5 months postinjury and made an uneventful recovery. PMID:23234820
Barlow, Brian T; McLawhorn, Alexander S; Westrich, Geoffrey H
2017-05-03
Dislocation remains a clinically important problem following primary total hip arthroplasty, and it is a common reason for revision total hip arthroplasty. Dual mobility (DM) implants decrease the risk of dislocation but can be more expensive than conventional implants and have idiosyncratic failure mechanisms. The purpose of this study was to investigate the cost-effectiveness of DM implants compared with conventional bearings for primary total hip arthroplasty. Markov model analysis was conducted from the societal perspective with use of direct and indirect costs. Costs, expressed in 2013 U.S. dollars, were derived from the literature, the National Inpatient Sample, and the Centers for Medicare & Medicaid Services. Effectiveness was expressed in quality-adjusted life years (QALYs). The model was populated with health state utilities and state transition probabilities derived from previously published literature. The analysis was performed for a patient's lifetime, and costs and effectiveness were discounted at 3% annually. The principal outcome was the incremental cost-effectiveness ratio (ICER), with a willingness-to-pay threshold of $100,000/QALY. Sensitivity analyses were performed to explore relevant uncertainty. In the base case, DM total hip arthroplasty showed absolute dominance over conventional total hip arthroplasty, with lower accrued costs ($39,008 versus $40,031 U.S. dollars) and higher accrued utility (13.18 versus 13.13 QALYs) indicating cost-savings. DM total hip arthroplasty ceased being cost-saving when its implant costs exceeded those of conventional total hip arthroplasty by $1,023, and the cost-effectiveness threshold for DM implants was $5,287 greater than that for conventional implants. DM was not cost-effective when the annualized incremental probability of revision from any unforeseen failure mechanism or mechanisms exceeded 0.29%. The probability of intraprosthetic dislocation exerted the most influence on model results. This model determined that, compared with conventional bearings, DM implants can be cost-saving for routine primary total hip arthroplasty, from the societal perspective, if newer-generation DM implants meet specific economic and clinical benchmarks. The differences between these thresholds and the performance of other contemporary bearings were frequently quite narrow. The results have potential application to the postmarket surveillance of newer-generation DM components. Economic and decision analysis Level III. See Instructions for Authors for a complete description of levels of evidence.
The effect of soft tissue release of the hips on walking in myelomeningocele.
Correll, J; Gabler, C
2000-06-01
Walking and standing capacity in myelomeningocele is highly dependent on the level of the neurological lesion. Deformities, mainly flexion deformities, of the hip can severely interfere with mobility. In a retrospective study, undertaken in our hospital, we evaluated the role of soft tissue release of the hip in patients with hip flexion contractures. A special surgical technique was performed in 55 hips. The results show a good effect on verticalization, even if the hip joints cannot be extended actively. A subluxated or dislocated hip did not influence the final outcome. During the mean follow-up of approximately 4 years, only a slight recurrence of the former deformity was observed. Most of the patients obtained great advantage from the operation.
Hoell, Steffen; Sander, Marius; Gosheger, Georg; Ahrens, Helmut; Dieckmann, Ralf; Hauschild, Gregor
2014-03-12
There have been increasing numbers of publications in recent years on minimally invasive surgery (MIS) for total hip arthroplasty (THA), reporting results with the use of different head sizes, tribologic and functional outcomes. This study presents the results and early complication rates after THA using the direct anterior approach (DAA) in combination with head sizes ≥ 36 mm. A total of 113 patients with THA were included in the study. The Harris Hip Score (HHS) was determined, a radiographic evaluation was carried out, and complications were recorded. The minimum follow-up period was 2 years (means 35 ± 7 months). The HHS improved from 43.6 (± 12) to 88.2 (± 14; P < 0.01). One early infection occurred, one periprosthetic fracture, and three cases of aseptic stem loosening. No incorrect positioning of the implants was observed, and there were no dislocations. THA with the minimally invasive DAA in combination with large heads is associated with good to very good functional results in the majority of cases. The complication rates are not increased. The rate of dislocation mainly as an complication of the first two years can be markedly reduced in particular.
Outcomes of dual mobility cups in a young Middle Eastern population and its influence on life style.
Assi, Chahine; El-Najjar, Elie; Samaha, Camille; Yammine, Kaissar
2017-03-01
Dual mobility cups (DMC) in total hip arthroplasty (THA) are becoming popular among orthopaedic surgeons. Substantial benefit of their use has been reported among high risk patients, particularly in reducing post-operative hip instability (dislocation). Many reports stated some concern when implanted in young and active people where complications such as polyethylene wear and mechanical loosening could potentially be higher. This Middle Eastern study analyses a retrospective series of THA for any aetiology other than infection, using DMC for the acetabular component in 75 patients (85 implants) less than 70 years old. No instability, intra-prosthetic dislocation or mechanical failure was reported during a mean follow-up of five years. The only major complication was a post-operative infection. The mean post- operative modified Harris hip score was 97.1 out of 100. All patients resumed their daily activities and all religious practicing patients were able to accomplish their prayer positions without pain. DMC is found to be an interesting option in reducing dislocation events in young patients. Those excellent short-term results would encourage surgeons to use DMC in an active and highly demanding population. Further research is necessary to confirm maintenance of such results at long term follow-up.
Schaeffer, Emily K; Study Group, Ihdi; Mulpuri, Kishore
2018-05-07
There is a lack of high quality evidence available to guide clinical practice in the treatment and management of developmental dysplasia of the hip (DDH). Evidence has been limited by persistent confusion on diagnostic and classification terminology, variability in surgeon decision making and a reliance on single centre, retrospective studies with small patient numbers. To address gaps in knowledge regarding screening, diagnosis and management of DDH, the International Hip Dysplasia Institute began a multicentre, international prospective study on infants with hips dislocated at rest. This review discusses the current state of screening, diagnostic and management practices in DDH and addresses important unanswered questions that will be critical in identifying best practices and optimising patient outcomes. There is insufficient evidence to support universal ultrasound screening; instead, selective screening should be performed by 6-8 weeks of age on infants with risk factors of breech presentation, family history, or history of clinical hip instability. Follow-up of infants with risk factors and normal initial screening should be considered to at least 6 months of age. Brace treatment is a sensible first-line treatment for management of dislocated hips at rest in infants < 6 months of age. Early operative reduction may be considered as there is insufficient evidence to support a protective role for the ossific nucleus in the development of avascular necrosis.
Implementing Capsule Representation in a Total Hip Dislocation Finite Element Model
Stewart, Kristofer J; Pedersen, Douglas R; Callaghan, John J; Brown, Thomas D
2004-01-01
Previously validated hardware-only finite element models of THA dislocation have clarified how various component design and surgical placement variables contribute to resisting the propensity for implant dislocation. This body of work has now been enhanced with the incorporation of experimentally based capsule representation, and with anatomic bone structures. The current form of this finite element model provides for large deformation multi-body contact (including capsule wrap-around on bone and/or implant), large displacement interfacial sliding, and large deformation (hyperelastic) capsule representation. In addition, the modular nature of this model now allows for rapid incorporation of current or future total hip implant designs, accepts complex multi-axial physiologic motion inputs, and outputs case-specific component/bone/soft-tissue impingement events. This soft-tissue-augmented finite element model is being used to investigate the performance of various implant designs for a range of clinically-representative soft tissue integrities and surgical techniques. Preliminary results show that capsule enhancement makes a substantial difference in stability, compared to an otherwise identical hardware-only model. This model is intended to help put implant design and surgical technique decisions on a firmer scientific basis, in terms of reducing the likelihood of dislocation. PMID:15296198
1997 Accession Medical Standards Analysis & Research Activity (AMSARA) Annual Report
1998-05-01
3.7 Hip Dental 13 2.8 Hip dislocation 44 2.1 Injury-lower 11 2.4 Foot-ankle 41 1.9 extremities Prior knee surgery .7 1.5 Curvature of the spine 35...Genetic Influences in Childhood-Onset Psychiatric Disorders: Autism and Attention-Deficit/Hyperactivity Disorder. Am J Hum Genet 1997;60:1276-1282
Yoon, Byung-Ho; Lee, Kyung-Hag; Noh, Serae; Ha, Yong-Chan; Lee, Young-Kyun; Koo, Kyung-Hoi
2013-12-01
Concerns of patients on sexual activity after total hip arthroplasty have not been well studied in Asian patients. This study aimed to determine the following: (1) what are the concerns of patients related to sexual activity after total hip arthroplasty? (2) what are the changes in sexual activity after total hip replacement in Korean patients? Details of sexual activity and concerns were obtained using a questionnaire designed specifically for the study. The questionnaire was administered to 64 patients in a face-to-face interview at an outpatient clinic. Preoperatively, 53.1% of patients experienced difficulties, primarily due to hip pathology and limitations of motion. The median time to the resumption of sexual activity was 3 months postoperatively, and most patients had no increase in the frequency of sexual activity after the total hip replacement. In 39.1% of patients were seen having difficulties with leg positioning following total hip replacement, and they were likely to change coital positions. The most common concern regarding sexual activity of patients was the fear of dislocation. Furthermore, patients with a higher stress level had lower satisfaction rates. Most patients were unable to obtain information on sexual activity following the total hip arthroplasty, and they did not consult with a physician due to the private nature of the topic. Dislocation was the most common concern of patients during sexual activity following a total hip arthroplasty, and a higher stress level was found to be associated with a lower satisfaction rate. Because most patients were unprepared to consult a physician, the provision of appropriate information before a consultation might be beneficial.
Yoon, Byung-Ho; Lee, Kyung-Hag; Noh, Serae; Ha, Yong-Chan; Koo, Kyung-Hoi
2013-01-01
Background Concerns of patients on sexual activity after total hip arthroplasty have not been well studied in Asian patients. This study aimed to determine the following: (1) what are the concerns of patients related to sexual activity after total hip arthroplasty? (2) what are the changes in sexual activity after total hip replacement in Korean patients? Methods Details of sexual activity and concerns were obtained using a questionnaire designed specifically for the study. The questionnaire was administered to 64 patients in a face-to-face interview at an outpatient clinic. Results Preoperatively, 53.1% of patients experienced difficulties, primarily due to hip pathology and limitations of motion. The median time to the resumption of sexual activity was 3 months postoperatively, and most patients had no increase in the frequency of sexual activity after the total hip replacement. In 39.1% of patients were seen having difficulties with leg positioning following total hip replacement, and they were likely to change coital positions. The most common concern regarding sexual activity of patients was the fear of dislocation. Furthermore, patients with a higher stress level had lower satisfaction rates. Most patients were unable to obtain information on sexual activity following the total hip arthroplasty, and they did not consult with a physician due to the private nature of the topic. Conclusions Dislocation was the most common concern of patients during sexual activity following a total hip arthroplasty, and a higher stress level was found to be associated with a lower satisfaction rate. Because most patients were unprepared to consult a physician, the provision of appropriate information before a consultation might be beneficial. PMID:24340146
Use of a Dual Mobility Socket to Manage Total Hip Arthroplasty Instability
Pibarot, Vincent; Vaz, Gualter; Chevillotte, Christophe; Béjui-Hugues, Jacques
2008-01-01
Unconstrained tripolar hip implants provide an additional bearing using a mobile polyethylene component between the prosthetic head and the outer metal shell. Such a design increases the effective head diameter and therefore is an attractive option in challenging situations of unstable total hip arthroplasties. We report our experience with 54 patients treated using this dual mobility implant in such situations. We ascertained its ability to restore and maintain stability, and examined component loosening and component failure. At a minimum followup of 2.2 years (mean, 4 years; range, 2.2–6.8 years), one hip had redislocated 2 months postoperatively and was managed successfully without reoperation by closed reduction with no additional dislocation. Two patients required revision of the implant because of dislocation at the inner bearing. Technical errors were responsible for these failures. Three patients had reoperations for deep infections. The postoperative radiographs at latest followup showed very satisfactory osseointegration of the acetabular component because no radiolucent line or osteolysis was reported. Use of this unconstrained tripolar design was successful in restoring and maintaining hip stability. We observed encouraging results at short-term followup regarding potential for loosening or mechanical failures. Level of Evidence: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence. PMID:18780135
Kahloul, Mohamed; Nakhli, Mohamed Said; Chouchene, Amine; Chebbi, Nidhal; Mhamdi, Salah; Naija, Walid
2017-01-01
Introduction Hip fracture is a frequent and severe disease. Its prognosis depends on the perioperative hemodynamic stability which can be preserved by the unilateral spinal anesthesia especially with low doses of local anesthetics. This study aims to compare the efficacy and hemodynamic stability of two doses of hypobaric bupivacaine (7.5 mg vs 5 mg) in unilateral spinal anesthesia. Methods In this prospective, randomized, double-blind study, 108 patients scheduled for hip fracture surgery under unilateral spinal anesthesia were enrolled to receive either 5 mg (group 1) or 7.5 mg (group 2) of hypobaric bupivacaine. Spinal anesthesia was performed in lateral position. Patients’ socio-demographic characteristics, hemodynamic profile, sensory and motor blocks parameters were recorded. Results Both groups were comparable regarding to demographic data. Two cases of failure occurred in group 1 and one case in group 2 corresponding to a comparable efficiency rates (96.29% and 98.14% respectively; p = 0.5). A higher mean onset and lower mean regression times of sensory block were significantly noted in group 1 (7.79±3.76 min vs 5.75±2.35 min, p < 0.001 and 91.29±31.55 min vs 112.77±18.77 min, p <0.001 respectively). Incidence of bilateralization (29.62% vs 87.03%, p < 0.001), incidence of hypotensive episodes (59.25% vs 92.59%, p < 0.001) and vascular loading (1481.48±411.65 ml vs 2111.11±596.10 ml, p < 0.001) were significantly higher in group 2. Conclusion The dosage of 5mg of hypobaric bupivacaine in unilateral spinal anesthesia is as effective as the dosage of 7.5 mg with lower bilateralization incidence and better hemodynamic stability. PMID:29515726
Kahloul, Mohamed; Nakhli, Mohamed Said; Chouchene, Amine; Chebbi, Nidhal; Mhamdi, Salah; Naija, Walid
2017-01-01
Hip fracture is a frequent and severe disease. Its prognosis depends on the perioperative hemodynamic stability which can be preserved by the unilateral spinal anesthesia especially with low doses of local anesthetics. This study aims to compare the efficacy and hemodynamic stability of two doses of hypobaric bupivacaine (7.5 mg vs 5 mg) in unilateral spinal anesthesia. In this prospective, randomized, double-blind study, 108 patients scheduled for hip fracture surgery under unilateral spinal anesthesia were enrolled to receive either 5 mg (group 1) or 7.5 mg (group 2) of hypobaric bupivacaine. Spinal anesthesia was performed in lateral position. Patients' socio-demographic characteristics, hemodynamic profile, sensory and motor blocks parameters were recorded. Both groups were comparable regarding to demographic data. Two cases of failure occurred in group 1 and one case in group 2 corresponding to a comparable efficiency rates (96.29% and 98.14% respectively; p = 0.5). A higher mean onset and lower mean regression times of sensory block were significantly noted in group 1 (7.79±3.76 min vs 5.75±2.35 min, p < 0.001 and 91.29±31.55 min vs 112.77±18.77 min, p <0.001 respectively). Incidence of bilateralization (29.62% vs 87.03%, p < 0.001), incidence of hypotensive episodes (59.25% vs 92.59%, p < 0.001) and vascular loading (1481.48±411.65 ml vs 2111.11±596.10 ml, p < 0.001) were significantly higher in group 2. The dosage of 5mg of hypobaric bupivacaine in unilateral spinal anesthesia is as effective as the dosage of 7.5 mg with lower bilateralization incidence and better hemodynamic stability.
Ahmed, Mohammed M; Otto, Thomas J; Moed, Berton R
2016-04-22
Limited-incision total hip arthroplasty (THA) preserves hip abductors, posterior capsule, and external rotators potentially diminishing dislocation risk. However, potential complications also exist, such as component malposition. Specific implants have been manufactured that enhance compatibility with this technique, while preserving metaphyseal bone; however, little data exists documenting early complications and component position. The purpose was to evaluate primary THA using a curved, bone-sparing stem inserted through the anterior approach with respect to component alignment and early complications. In a retrospective analysis of 108 cases, the surgical technique was outlined and the occurrence of intraoperative fractures, postoperative dislocations, infection, and limb length inequality was determined. Femoral stem and acetabular cup alignment was quantified using the initial postoperative radiographs. Patient follow-up averaged 12.9 (range 2 to 36) months. There were eight (7.4 %) complications requiring revision surgery in three (2.8 %) patients with three (2.8 %) infections and three (2.8 %) dislocations. Intraoperative complications included one calcar fracture above the lesser trochanter. Leg length inequality >5 mm was present in three (2.8 %) patients. Radiographic analysis showed that femoral neutral alignment was achieved in 95 hips (88.0 %). All femoral stems demonstrated satisfactory fit and fill and no evidence of subsidence, osteolysis, or loosening. An average abduction angle of 44.8° (± 5.3) and average cup anteversion of 16.2° (± 4.2) were also noted. Although the technique with this implant and approach is promising, it does not appear to offer important advantages over standard techniques. However, the findings merit further, long-term study.
[Post-anesthetic autologous blood donation used in knee and hip arthroplasty].
Wei, Wei; Kou, Bolong; Ju, Rongseng
2006-06-01
To explore the clinical application of the postanesthetic autologous donation and the postoperative transfusion during the knee and hip replacement surgeries. Thirty-three patients (17 males, 16 females) admitted for the elective joint replacement surgeries from September 2004 to January 2005 were included in this study. Of the 33 patients, 5 were diagnosed with rheumatoid arthritis, 23 with femoral head necrosis, and 5 with knee osteoarthritis. Immediately after anesthesia, 400 ml of the blood was drawn and transfused after the surgery. The blood pressure was monitored during the blood drawing, postoperative blood parameters were recorded, surgical site drainage and signs of infections were observed, and the other clinical data were collected. Of the 33 patients, 27 only received autologous transfusion, including 21 patients who underwent the unilateral hip replacement and 6 patients who underwent the unilateral knee replacement. All these 6 patients with the unilateral knee replacement received the blood drained from the surgical sites in addition to the blood obtained from the post-anesthetic autologous donation. Another 6 cases with the bilateral hip and knee replacement received the blood drained from the surgical sites, the blood obtained from the post-anesthetic autologous donation and 400 ml of the allogeneic blood transfusion. The blood received postoperatively averaged 650 ml (range, 200-1 150 ml), haemoglobin (Hb) was averaged 88 g/L (68-102 g/L), and Hct was averaged 24.6% (20.5%-31.5%). Hb and Hct were lower after operation than before operation (P < 0.01). Postoperative blood transfusion following the postanesthetic and preoperative autologous donation can be successfully applied to most of the patients undergoing the knee or hip replacement so as to reduce complications of the allogeneic blood transfusion.
Ning, Bo; Yuan, Yi; Yao, Jie; Zhang, Sichng; Sun, Jun
2014-11-28
The one-stage procedure for treatment of older developmental dislocation of the hip (DDH) is used widely. However, the best age group for this operation is still unknown. The aims of our study were to evaluate middle-term outcomes of one-stage surgical treatment of a large number of patients with late-diagnosed DDH, and to explore the best age group for treatment. We retrospectively reviewed 652 patients with a total of 864 hip joints with DDH, all aged >18 months. All the hip joints were treated with one-stage procedures including open reduction, pelvic osteotomy, and femoral shortening. The patients were divided into three groups according to age at surgery: Group I: 1.5-2.5 years; Group II: 2.5-8 years; and Group III: >8 years. The latest clinical and radiographic outcomes, complications and avascular necrosis (AVN) of the femoral head were evaluated and compared among the three groups. The mean age at surgery was 5.8 years (range: 1.5-13.2 years). The average time of follow-up was 6.2 years (range: 3.2-8.9 years). A total of 79.4% of good or excellent outcomes were obtained for clinical functional evaluation according to the McKay classification. For radiographic outcomes, 732 hips (84.7%) were classified as good or excellent according to the Severin classification. A total of 27.4% of all hips had a poor outcome according to the Kalamchi and MacEwen classification for AVN. The poorest outcomes were observed for clinical, radiographic and AVN results in Group III (p < 0.001). Compared with Group I, the better results for clinical and AVN outcomes were found in Group II (p < 0.001). However, similar clinical outcomes were observed between Groups I and II (p > 0.05). A significantly higher incidence of redislocation and residual acetabular dysplasia was observed in Tonnis grade II and III hip dislocation (p < 0.001). One-stage treatment of late-diagnosed DDH had a good outcome in young and middle group. Younger patients achieved better results than older patients. However, the best age group was 2.5-8 years. Tonnis grade II and III DDH is a risk factor for redislocation and residual acetabular dysplasia after the one-stage operation.
Wellenberg, R H H; Boomsma, M F; van Osch, J A C; Vlassenbroek, A; Milles, J; Edens, M A; Streekstra, G J; Slump, C H; Maas, M
2017-03-01
To quantify the impact of prosthesis material and design on the reduction of metal artefacts in total hip arthroplasties using virtual monochromatic dual-layer detector Spectral CT imaging. The water-filled total hip arthroplasty phantom was scanned on a novel 128-slice Philips IQon dual-layer detector Spectral CT scanner at 120-kVp and 140-kVp at a standard computed tomography dose index of 20.0mGy. Several unilateral and bilateral hip prostheses consisting of different metal alloys were inserted and combined which were surrounded by 18 hydroxyapatite calcium carbonate pellets representing bone. Images were reconstructed with iterative reconstruction and analysed at monochromatic energies ranging from 40 to 200keV. CT numbers in Hounsfield Units (HU), noise measured as the standard deviation in HU, signal-to-noise-ratios (SNRs) and contrast-to-noise-ratios (CNRs) were analysed within fixed regions-of-interests placed in and around the pellets. In 70 and 74keV virtual monochromatic images the CT numbers of the pellets were similar to 120-kVp and 140-kVp polychromatic results, therefore serving as reference. A separation into three categories of metal artefacts was made (no, mild/moderate and severe) where pellets were categorized based on HU deviations. At high keV values overall image contrast was reduced. For mild/moderate artefacts, the highest average CNRs were attained with virtual monochromatic 130keV images, acquired at 140-kVp. Severe metal artefacts were not reduced. In 130keV images, only mild/moderate metal artefacts were significantly reduced compared to 70 and 74keV images. Deviations in CT numbers, noise, SNRs and CNRs due to metal artefacts were decreased with respectively 64%, 57%, 62% and 63% (p<0.001) compared to unaffected pellets. Optimal keVs, based on CNRs, for different unilateral and bilateral metal hip prostheses consisting of different metal alloys varied from 74 to 150keV. The Titanium alloy resulted in less severe artefacts and were reduced more effectively compared to the Cobalt alloy. Virtual monochromatic dual-layer Spectral CT imaging results in a significant reduction of streak artefacts produced by beam-hardening in mild and moderate artefacts by improving CT number accuracy, SNRs and CNRs, while decreasing noise values in a total hip arthroplasty phantom. An optimal monochromatic energy of 130keV was found ranging from 74keV to 150keV for different unilateral and bilateral hip prostheses consisting of different metal alloys. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.
Congenital Dislocation of the Hip
Specht, Elmer E.
1976-01-01
Congenital dislocation or subluxation of the hip (congenital acetabular dysplasia) is a complete or partial displacement of the femoral head out of the acetabulum. The physical signs essential for diagnosis are age related. In newborns the tests for instability are the most sensitive. After the neonatal period, and until the age of walking, tightness of the adductor muscles is the most reliable sign. Early diagnosis is vital for successful treatment of this partially genetically determined condition. Various therapeutic measures, ranging from abduction splinting to open reduction and osteotomy, may be required. Following diagnosis in the first month of life, the average treatment time in one recent series was only 2.3 months from initiation of therapy to attainment of a normal hip. When the diagnosis was not made until 3 to 6 months of age, ten months of treatment was required to achieve the same outcome. When the diagnosis is not made, or the treatment is not begun until after the age of 6, a normal hip will probably not develop in any patient. ImagesFigure 1.Figure 2.Figure 3.Figure 4.Figure 5.Figure 6.Figure 7.Figure 8.Figure 9. PMID:1251603
Schoenfeld, Timothy J.; Kloth, Alexander D.; Hsueh, Brian; Runkle, Matthew B.; Kane, Gary A.; Wang, Samuel S.-H.
2014-01-01
Anxiety disorders are highly prevalent but little is known about their underlying mechanisms. Gap junctions exist in brain regions important for anxiety regulation, such as the ventral hippocampus (vHIP) and mPFC, but their functions in these areas have not been investigated. Using pharmacological blockade of neuronal gap junctions combined with electrophysiological recordings, we found that gap junctions play a role in theta rhythm in the vHIP and mPFC of adult mice. Bilateral infusion of neuronal gap junction blockers into the vHIP decreased anxiety-like behavior on the elevated plus maze and open field. Similar anxiolytic effects were observed with unilateral infusion of these drugs into the vHIP combined with contralateral infusion into the mPFC. No change in anxious behavior was observed with gap junction blockade in the unilateral vHIP alone or in the bilateral dorsal HIP. Since physical exercise is known to reduce anxiety, we examined the effects of long-term running on the expression of the neuronal gap junction protein connexin-36 among inhibitory interneurons and found a reduction in the vHIP. Despite this change, we observed no alteration in theta frequency or power in long-term runners. Collectively, these findings suggest that neuronal gap junctions in the vHIP–mPFC pathway are important for theta rhythm and anxiety regulation under sedentary conditions but that additional mechanisms are likely involved in running-induced reduction in anxiety. PMID:25411496
Tateuchi, Hiroshige; Wada, Osamu; Ichihashi, Noriaki
2011-06-01
Understanding the kinematic chain from foot to thorax will provide a better basis for assessment of malalignment of the body. The purpose of this study was to investigate the effects of induced calcaneal eversion on the kinematics of the hip, pelvis and thorax in three dimensions under unilateral weight-bearing. Twenty-eight healthy males were requested to stand on one leg under three conditions: normal (standing directly on the floor), and on wedges producing 5° and 10° calcaneal eversion. Recorded kinematic parameters included the angles of the hip joint, pelvis, and thorax in three dimensions. Eversion induced by wedges produced significant increases in hip flexion, hip medial rotation, pelvic anterior tilt, and thoracic lateral tilt and axial rotation to the standing side. In the frontal plane, pelvic lateral tilt to the standing side was decreased in 5° eversion condition compared with normal condition; conversely, it was increased in 10° eversion condition compared with 5° eversion condition. Arch height was negatively correlated with change in thoracic axial rotation to standing side from the normal to 10° eversion (r=-.528, p<.01). We concluded that induced calcaneal eversion affects the three-dimensional kinematics of the thorax through the hip joint and the pelvis. Copyright © 2011 Elsevier B.V. All rights reserved.
Evaluation of local bone turnover in painful hip by 18F-fluoride positron emission tomography.
Kobayashi, Naomi; Inaba, Yutaka; Tezuka, Taro; Ike, Hiroyuki; Kubota, So; Kawamura, Masaki; Saito, Tomoyuki
2016-04-01
The diagnosis of painful hip without remarkable radiographic findings is still challenging. In recent years, femoroacetabular impingement (FAI) has been recognized as an important cause of painful hip. The hypothesis of this study was that local bone turnover may be accelerated in painful hip, especially in FAI lesions. To test this, patients with unilateral symptomatic hip underwent F-fluoride PET, which directly correlates with osteoblast activity and therefore bone turnover. In total, 27 patients with unilateral symptomatic painful hip were enrolled. The diagnosis included 15 cam-type FAI cases, six labral tear cases, and six early-stage osteoarthritis cases. The region of interest for cam and pincer lesions was identified and the maximum standardized uptake value (SUVmax) in these regions and the contralateral asymptomatic regions were measured by F-fluoride PET. The SUVmax ratio was defined as symptomatic side SUVmax/asymptomatic side SUVmax. The α angle and center-edge angle were measured by plain radiograph. The SUVmax of both cam and pincer lesions were significantly higher than the SUVmax of the contralateral regions (P<0.0001). The cam SUVmax ratio correlated positively with the α angle (r=0.5, P=0.007). Patients with an α angle of more than or equal to 60° had a significantly higher cam SUVmax ratio than the less than 60° group (P=0.017). This study showed the accelerated local bone turnover in painful hip, partly in FAI cases. Accelerated bone turnover may play a significant role in FAI pathophysiology; therefore, its recognition by imaging modality may contribute toward a more sensitive diagnosis in painful hip.
Glasser, S; Collings, R; Paton, J; Marsden, J
2015-07-01
This study assessed whether postural responses induced by vibratory perturbations of the hip abductors and ankle evertors, were modified when distal tactile sensation was experimentally reduced through cooling. Sixteen healthy subjects were investigated pre and post cooling. Subjects stood with their eyes closed with a stance width of 4 cm. A 2s vibratory stimulus was applied to the left or right hip abductor or ankle evertor muscle. The order of the site and side of the stimulation was randomised. The postural response to hip abductor and ankle evertor vibration was recorded using 3D motion analysis (Codamotion, Leicestershire). Medio-lateral centre of pressure motion was simultaneously recorded during quiet standing via a force plate (Kistler, UK). Pre-cooling people responded to unilateral ankle vibration with an ipsilateral translation and tilt of the pelvis, and an ipsilateral tilt of the trunk. People responded to unilateral hip vibration with a contralateral translation and tilt of the pelvis, and an ipsilateral tilt of the trunk. Following an experimental reduction in distal tactile sensation there was a significant reduction in the amplitude of pelvic tilt in response to ankle vibration (F(6.2)=P<0.05) and a significant increase in amplitude of pelvic tilt in response to hip vibration (F(5.2)=P<0.05). This suggests that the sensitivity to artificial stimulation of hip proprioception increases with distal cooling, possibly indicating a change in the gain/weighting placed upon sensory information from the hips. Copyright © 2015 Elsevier B.V. All rights reserved.
Cement-in-cement acetabular revision with a constrained tripolar component.
Leonidou, Andreas; Pagkalos, Joseph; Luscombe, Jonathan
2012-02-17
Dislocation of a total hip replacement (THR) is common following total hip arthroplasty (THA). When nonoperative management fails to maintain reduction, revision surgery is considered. The use of constrained acetabular liners has been extensively described. Complete removal of the old cement mantle during revision THA can be challenging and is associated with significant complications. Cement-in-cement revision is an established technique. However, the available clinical and experimental studies focus on femoral stem revision. The purpose of this study was to present a case of cement-in-cement acetabular revision with a constrained component for recurrent dislocations and to investigate the current best evidence for this technique. This article describes the case of a 74-year-old woman who underwent revision of a Charnley THR for recurrent low-energy dislocations. A tripolar constrained acetabular component was cemented over the primary cement mantle following removal of the original liner by reaming, roughening the surface, and thoroughly irrigating and drying the primary cement. Clinical and radiological results were good, with the Oxford Hip Score improving from 11 preoperatively to 24 at 6 months postoperatively. The good short-term results of this case and the current clinical and biomechanical data encourage the use of the cement-in-cement technique for acetabular revision. Careful irrigation, drying, and roughening of the primary surface are necessary. Copyright 2012, SLACK Incorporated.
Lawsuits After Primary and Revision Total Hip Arthroplasties: A Malpractice Claims Analysis.
Patterson, Diana C; Grelsamer, Ronald P; Bronson, Michael J; Moucha, Calin S
2017-10-01
As the prevalence of total hip arthroplasty (THA) expands, so too will complications and patient dissatisfaction. The goal of this study was to identify the common etiologies of malpractice suits and costs of claims after primary and revision THAs. Analysis of 115 malpractice claims filed for alleged neglectful primary and revision THA surgeries by orthopedic surgeons insured by a large New York state malpractice carrier between 1983 and 2011. The incidence of malpractice claims filed for negligent THA procedures is only 0.15% per year in our population. In primary cases, nerve injury ("foot drop") was the most frequent allegation with 27 claims. Negligent surgery causing dislocation was alleged in 18 and leg length discrepancy in 14. Medical complications were also reported, including 3 thromboembolic events and 6 deaths. In revision cases, dislocation and infection were the most common source of suits. The average indemnity payment was $386,153 and the largest single settlement was $4.1 million for an arterial injury resulting in amputation after a primary hip replacement. The average litigation cost to the insurer was $61,833. Nerve injury, dislocation, and leg length discrepancy are the most common reason for malpractice after primary THA. Orthopedic surgeons should continue to focus on minimizing the occurrence of these complications while adequately incorporating details about the risks and limitations of surgery into their preoperative education. Copyright © 2017 Elsevier Inc. All rights reserved.
Acute unilateral hip pain in fibrodysplasia ossificans progressiva (FOP).
Kaplan, Frederick S; Al Mukaddam, Mona; Pignolo, Robert J
2018-04-01
Flare-ups of the hips are among the most feared and disabling complications of fibrodysplasia ossificans progressiva (FOP) and are poorly understood. In order to better understand the nature of hip flare-ups in FOP, we evaluated 25 consecutive individuals with classic FOP (14 males, 11 females; 3-56years old, median age, 17years old) who presented with acute unilateral hip pain. All 25 individuals were suspected of having a flare-up of the hip based on clinical history and a favorable response to a four day course of high-dose oral prednisone. Ten individuals (40%) experienced rebound symptoms of pain and/or stiffness within seven days after discontinuation of prednisone and all ten subsequently developed heterotopic ossification (HO) or decreased mobility of the affected hip. None of the 14 individuals who experienced sustained relief of symptoms following a course of oral prednisone experienced HO or decreased mobility. Incidental radiographic findings at the time of presentation were multifactoral and included osteochondromas of the proximal femur (18/25; 72%), degenerative arthritis (17/25; 68%), developmental hip dysplasia (15/25; 60%), previously existing heterotopic ossification (12/25; 48%), intra-articular synovial osteochondromatosis (8/25; 32%) or traumatic fractures through pre-existing heterotopic bone (1/25; 4%). Developmental joint pathology may confound clinical evaluation of hip pain in FOP. The most useful modality for suspecting an ossification-prone flare-up of the hip was lack of sustained response to a brief course of oral prednisone. Evaluation of soft tissue edema by ultrasound or magnetic resonance imaging showed promise in identifying ossification-prone flare-ups and warrants further analysis in prospective studies. Copyright © 2017 Elsevier Inc. All rights reserved.
Doherty, Michael; Courtney, Philip; Doherty, Sally; Jenkins, Wendy; Maciewicz, Rose A; Muir, Kenneth; Zhang, Weiya
2008-10-01
To determine whether 2-dimensional measures of femoral head shape and angle are associated with hip osteoarthritis (OA). We compared cases with symptomatic radiographic hip OA with asymptomatic controls with no radiographic hip OA. On anteroposterior pelvis radiographs, we measured "pistol grip deformity" for each hip (visually categorized as nonspherical, indeterminate, or spherical), the femoral head-to-femoral neck ratio as an interval measure of femoral head shape, and the femoral neck shaft angle. The relative risk of hip OA associated with each feature was estimated using odds ratios (ORs) and 95% confidence intervals (95% CIs), adjusted for possible confounders using a logistic regression model. Of 1,007 cases, 965 had definite radiographic hip OA; of 1,123 controls, 1,111 had no radiographic OA. The prevalence of pistol grip deformity in at least 1 hip was 3.61% in controls and 17.71% in cases (OR 6.95 [95% CI 4.64-10.41]), and the prevalence of abnormal femoral head-to-femoral neck ratio in at least 1 hip was 3.70% in controls and 24.27% in cases (OR 12.08 [95% CI 8.05-18.15]). The risk of hip OA increased as the femoral head-to-femoral neck ratio decreased (P for trend<0.001) and with each extreme of neck shaft angle (P<0.05). In cases with unilateral hip OA, the prevalence of abnormal femoral head-to-femoral neck ratio in the unaffected hip was 2 times greater than that in controls (OR 1.82 [95% CI 1.07-3.07]); in contrast, an abnormally low, but not abnormally high, neck shaft angle was more common in unaffected hips than in controls (OR 1.79 [95% CI 1.03-3.14]). Our findings indicate that pistol grip deformity is associated with hip OA. The increased prevalence of pistol grip deformity and an abnormally low neck shaft angle in unaffected hips of cases with unilateral OA suggests that they are risk factors for development of hip OA. However, both a nonspherical head shape and an increase in neck shaft angle may occur as a consequence of OA.
Lee, Soong Joon; Kwak, Hong Suk; Yoo, Jeong Joon; Kim, Hee Joong
2016-01-01
We evaluated the short-term to midterm results of reoperation with bearing change to metal-on-polyethylene (MoP) after ceramic bearing fracture in ceramic-on-ceramic total hip arthroplasty. Nine third-generation ceramic bearing fractures (6 heads and 3 liners) were treated with bearing change to MoP. Mean age at reoperation was 52.7 years. Mean follow-up was 4.3 years. During follow-up, 2 of 3 liner-fractured hips and 1 of 6 head-fractured hips showed radiologic signs of metallosis and elevated serum chromium levels. Re-reoperation with bearing rechange to a ceramic head was performed for the hips with metallosis. One liner-fractured hip had periprosthetic joint infection. Dislocation occurred in 3 hips. From our experience, bearing change to MoP is not a recommended treatment option for ceramic bearing fracture in total hip arthroplasty. Copyright © 2016 Elsevier Inc. All rights reserved.
Jones, Kevin B.; Griffin, Anthony M.; Chandrasekar, Coonoor R.; Biau, David; Babinet, Antoine; Deheshi, Benjamin; Bell, Robert S.; Grimer, Robert J.; Wunder, Jay S.; Ferguson, Peter C.
2011-01-01
Background and Objectives Functional outcomes following oncologic total femoral endoprosthetic reconstruction (TFR) are lacking. We compared patient-oriented functional results of TFRs to proximal femur and distal femur reconstructions (PFR and DFR). We also compared function and complications with regard to knee and hip componentry. Methods 54 TFR patients were identified from 3 institutional prospective databases. 41 had fixed- and 13 had rotating-hinge knees, 37 hemiarthroplasty and 17 total hip arthroplasty componentry. Toronto Extremity Salvage Scores (TESS) for n=27 were compared between groups and to cohorts of PFR (n=31) and DFR (n=85) patients using the Mann-Whitney U test. Results Follow-up averaged 4 years. Mechanical complications included 5 hip dislocations and 1 femoral malrotation. Four dislocations were in fixed-hinge implants, all in those lacking abductor reattachment. TESS averaged 69.3±17.8, statistically decreased from DFR (p=0.002) and PFR patients (p=0.036). No significant differences were detected between patients in the fixed-hinge (n=18) and rotating-hinge (n=9) groups (p = 0.944), or total hip (n=8) and hemiarthroplasty (n=19) groups (p=0.633). Conclusions TFR is reserved for extreme cases of limb salvage, portending a poor prognosis overall. Function reflects additive impairments from PFR and DFR. TFR outcomes differ little with rotating- or fixed-hinge, total hip or hemiarthroplasty implants. PMID:21695701
Ozden, V Emre; Dikmen, G; Beksac, B; Tozun, I Remzi
2017-06-01
The results of cementless stems in total hip arthroplasty (THA) done because of congenital dislocation with step-cut osteotomy is not well known, particularly the influence of the design and the role of extent of porous coating. Therefore we performed a retrospective study to evaluate the mid to long-term results THA performed with a single type acetabular component and different geometry and fixation type stems with ceramic bearings in the setting of step-cut subtrochanteric osteotomy in high hip dislocated (HHD) patients. We asked if the stem type affect the outcomes in terms of (1) intra and postoperative complication rates (2) radiographic outcomes (3) prosthesis survival in step-cut subtrochanteric shortening osteotomy. The type of the stem, whether cylindrical or tapered does not affect the outcome if the femoral canal fit and fill is obtained and the step-cut femoral shortening osteotomy is primarily fixed. Forty-five hips in 35 patients with a mean follow up of 10 years (range, 7-14 years) were evaluated. The single type cementless cup was placed at the level of the true acetabulum, a step-cut shortening femoral osteotomy was performed and reconstruction was performed with two different types of tapered stem in twenty-two hips (Synergy™ and Image™ proximally coated, Smith and Nephew, Menphis, TN, USA) and one type of cylindrical stem (Echelon™ with 2/3 coated, Smith and Nephew, Menphis, TN, USA) in twenty-three hips. Harris hip scores (HHS) and a University of California Los Angeles (UCLA) activity scores were calculated for all patients and successive X-rays were evaluated regarding component loosening and osteolysis, along with complications related to bearing, step-cut osteotomy and stem types. Forty-one hips (91%) had good and excellent clinical outcome according to HHS. The mean UCLA activity scores improved from 3.2±0.6 points (range, 2-4) preoperatively to 6.3 points±0.5 (range, 5-7) at the latest follow-up. The mean femoral shortening was 36±10mm (range, 20-65mm). Four (9%) dislocations were observed. There were five (11%) intra-operative femoral fractures and three (7%) cases of non-union, which were observed in tapered stems. Cylindrical stems had superior neutral alignment primarily. With any stem revision as the end point, cylindrical stems had a higher survival rate (100%) than all tapered stems (82%; 95% confident interval [CI] 77-97%) at ten years. With any revision as the end point, the 10-year survival rate for acetabular component (Reflection-Ceramic Interfit) and for femoral components were 98% (95% CI, 85-99%) and 91% (95% CI, 78-97%), respectively. There were more implant related complications in HHD patients undergoing THA when tapered stems with 1/3 proximal coating were used to reconstruct a step cut osteotomized femur, compared to cylindrical stems 2/3 coated. IV, retrospective study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Natural substrate lift-off technique for vertical light-emitting diodes
NASA Astrophysics Data System (ADS)
Lee, Chia-Yu; Lan, Yu-Pin; Tu, Po-Min; Hsu, Shih-Chieh; Lin, Chien-Chung; Kuo, Hao-Chung; Chi, Gou-Chung; Chang, Chun-Yen
2014-04-01
Hexagonal inverted pyramid (HIP) structures and the natural substrate lift-off (NSLO) technique were demonstrated on a GaN-based vertical light-emitting diode (VLED). The HIP structures were formed at the interface between GaN and the sapphire substrate by molten KOH wet etching. The threading dislocation density (TDD) estimated by transmission electron microscopy (TEM) was reduced to 1 × 108 cm-2. Raman spectroscopy indicated that the compressive strain from the bottom GaN/sapphire was effectively released through the HIP structure. With the adoption of the HIP structure and NSLO, the light output power and yield performance of leakage current could be further improved.
Hip Dislocation and Dystocia in Early Medieval Times: Possible Evidence of Labor Maneuver.
Malgosa, Assumpció; Carrascal, Susana; Piga, Giampaolo; Isidro, Albert
2016-12-01
In ancient times, maternal mortality would occur frequently, particularly during labor. Evidence of dystocia resulting in the death of a pregnant woman is very infrequent in paleopathologic literature, with only a few cases being demonstrated. In the early medieval site of Casserres, the skeleton of a young woman with a fetus in the pelvic region was found. Some abnormal findings of the maternal skeleton were evaluated, including a sacral anomaly, femoral head wound, the rare position of the lower left limb with the femoral head dislodged anteriorly and cephalad from the socket, and a fibular fracture. Examining the anomalies all together, a case of anterior hip dislocation related to a McRoberts-like maneuver performed during labor is a plausible explanation of the findings.
Hoenig, L J
1997-02-01
This study describes in modern medical terms a traumatic hip injury suffered by the Biblical patriarch Jacob approximately 3,500 years ago. The case history is based on the original Hebrew text found in the Bible book of Genesis (Chapter 32:25-33) as interpreted by traditional Jewish commentaries on the Bible. Jacob sustained a hip injury in hand-to-hand combat with an adversary or through an intense physiological reaction to a prophetic vision of such a battle. He appears to have sustained neurological injury to his sciatic nerve as well as musculoskeletal damage to his hip. These injuries caused a temporary limping gait. Jacob probably sustained a neurapraxia of the sciatic nerve. The differential diagnosis of his musculoskeletal hip injury includes hip dislocation, fracture, soft tissue trauma, and articular pathology.
Disparity between Clinical and Ultrasound Examinations in Neonatal Hip Screening.
Kyung, Bong Soo; Lee, Soon Hyuck; Jeong, Woong Kyo; Park, Si Young
2016-06-01
For early detection of developmental dysplasia of the hip (DDH), neonatal hip screening using clinical examination and/or ultrasound has been recommended. Although there have been many studies on the reliability of both screening techniques, there is still controversy in the screening strategies; clinical vs. selective or universal ultrasound screening. To determine the screening strategy, we assessed the agreement among the methods; clinical examination by an experienced pediatric orthopedic surgeon, sonographic morphology, and sonographic stability. From January 2004 to June 2009, a single experienced pediatric orthopedic surgeon performed clinical hip screenings for 2,686 infants in the neonatal unit and 43 infants who were referred due to impressions of hip dysplasia before 3 months of age. Among them, 156 clinically unstable or high-risk babies selectively received bilateral hip ultrasound examinations performed by the same surgeon using the modified Graf method. The results were analyzed statistically to detect any correlations between the clinical and sonographic findings. Although a single experienced orthopedic surgeon conducted all examinations, we detected only a limited relationship between the results of clinical and ultrasound examinations. Ninety-three percent of the clinically subluxatable hips were normal or immature based on static ultrasound examination, and 74% of dislocating hips and 67% of limited abduction hips presented with the morphology below Graf IIa. A total of 80% of clinically subluxatable, 42% of dislocating and 67% of limited abduction hips appeared stable or exhibited minor instability on dynamic ultrasound examination. About 7% of clinically normal hips were abnormal upon ultrasound examination; 5% showed major instability and 3% showed dysplasia above Graf IIc. Clinical stability had small coefficients between ultrasound examinations; 0.39 for sonographic stability and 0.37 for sonographic morphology. Between sonographic stability and morphology, although 71% of hips with major instability showed normal or immature morphology according to static ultrasound examination, the coefficient was as high as 0.64. Discrepancies between clinical and ultrasound examinations were present even if almost all of the exams were performed by a single experienced pediatric orthopedic surgeon. In relation to screening for DDH, it is recommended that both sonographic morphology and stability be checked in addition to clinical examination.
Gonzalez, Amanda Inez; Bartolone, Placido; Lubbeke, Anne; Dupuis Lozeron, Elise; Peter, Robin; Hoffmeyer, Pierre; Christofilopoulos, Panayiotis
2017-02-01
Background and purpose - Revision total hip arthroplasty (THA) is associated with higher dislocation rates than primary THA. We compared the risk of dislocation within 6 months and all-cause re-revision during the whole study period using either the dual-mobility cup or the unipolar cup. Methods - We used a prospective hospital registry-based cohort including all total and cup-only revision THAs performed between 2003 and 2013. The cups used were either dual-mobility or unipolar; the choice was made according to the preference of the surgeon. 316 revision THAs were included. The mean age of the cohort was 69 (25-98) years and 160 THAs (51%) were performed in women. The dual-mobility group (group 1) included 150 THAs (48%) and the mean length of follow-up was 31 (0-128) months. The unipolar group (group 2) included 166 THAs (53%) and the mean length of follow-up was 52 (0-136) months. Results - The incidence of dislocation within 6 months was significantly lower with the dual-mobility cup than with the unipolar cup (2.7% vs. 7.8%). The unadjusted risk ratio (RR) was 0.34 (95% CI: 0.11-1.02) and the adjusted RR was 0.28 (95% CI: 0.09-0.87). The number of patients needed to treat with a dual-mobility cup in order to prevent 1 case of dislocation was 19. The unadjusted incidence rate ratio for all-cause re-revision in the dual-mobility group compared to the unipolar group was 0.6 (95% CI: 0.3-1.4). Interpretation - Use of a dual-mobility rather than a unipolar cup in revision THA reduced the risk of dislocation within 6 months.
Report of a new case and clinical delineation of mosaic trisomy 9 syndrome
Sánchez, José María; Fijtman, Nora; Migliorini, Ana María
1982-01-01
A newborn girl with trisomy 9 mosaicism is reported. Clinical findings included major malformations: bilateral hip dislocation, dislocation of the left knee, extreme micrognathia, and microsomy. Up to date, 11 liveborn infants with trisomy 9 have been reported, which allows us to make a karyotype/phenotype correlation. Minimal clinical diagnostic criteria are defined, on the basis of which the presence of this syndrome can be suspected. Images PMID:7143394
[Trigeminal motor paralysis and dislocation of the temporo-mandibular joints].
Ohkawa, S; Yoshida, T; Ohsumi, Y; Tabuchi, M
1996-07-01
A 64-year-old woman with diabetes mellitus was admitted to our hospital with left hemiparesis of sudden onset. A brain MRI demonstrated a cerebral infarction in the ventral part of the right lower pons. When left hemiparesis worsened, she had dislocation of the temporo-mandibular joints repeatedly. Then, her lower jaw deviated to the right when she opened her mouth. Also, there was decreased contraction of the right masseter when she clenched her teeth. These findings suggest that there was trigeminal motor paralysis on the right side resulting from involvement of the intrapontine trigeminal motor nerve. She has no history of dislocation of the temporo-mandibular joints. An X-ray film showed that the temporo-mandibular joints were intact. Thus, it is possible that deviation of the lower jaw was the cause of this dislocation. We suspect that dislocation of the temporo-mandibular joints may occur as a complication of unilateral trigeminal motor paralysis. This has not been reported to our knowledge.
The Impact of Lumbar Spine Disease and Deformity on Total Hip Arthroplasty Outcomes.
Blizzard, Daniel J; Sheets, Charles Z; Seyler, Thorsten M; Penrose, Colin T; Klement, Mitchell R; Gallizzi, Michael A; Brown, Christopher R
2017-05-01
Concomitant spine and hip disease in patients undergoing total hip arthroplasty (THA) presents a management challenge. Degenerative lumbar spine conditions are known to decrease lumbar lordosis and limit lumbar flexion and extension, leading to altered pelvic mechanics and increased demand for hip motion. In this study, the effect of lumbar spine disease on complications after primary THA was assessed. The Medicare database was searched from 2005 to 2012 using International Classification of Diseases, Ninth Revision, procedure codes for primary THA and diagnosis codes for preoperative diagnoses of lumbosacral spondylosis, lumbar disk herniation, acquired spondylolisthesis, and degenerative disk disease. The control group consisted of all patients without a lumbar spine diagnosis who underwent THA. The risk ratios for prosthetic hip dislocation, revision THA, periprosthetic fracture, and infection were significantly higher for all 4 lumbar diseases at all time points relative to controls. The average complication risk ratios at 90 days were 1.59 for lumbosacral spondylosis, 1.62 for disk herniation, 1.65 for spondylolisthesis, and 1.53 for degenerative disk disease. The average complication risk ratios at 2 years were 1.66 for lumbosacral spondylosis, 1.73 for disk herniation, 1.65 for spondylolisthesis, and 1.59 for degenerative disk disease. Prosthetic hip dislocation was the most common complication at 2 years in all 4 spinal disease cohorts, with risk ratios ranging from 1.76 to 2.00. This study shows a significant increase in the risk of complications following THA in patients with lumbar spine disease. [Orthopedics. 2017; 40(3):e520-e525.]. Copyright 2017, SLACK Incorporated.
Vanhegan, I S; Malik, A K; Jayakumar, P; Ul Islam, S; Haddad, F S
2012-05-01
Revision arthroplasty of the hip is expensive owing to the increased cost of pre-operative investigations, surgical implants and instrumentation, protracted hospital stay and drugs. We compared the costs of performing this surgery for aseptic loosening, dislocation, deep infection and peri-prosthetic fracture. Clinical, demographic and economic data were obtained for 305 consecutive revision total hip replacements in 286 patients performed at a tertiary referral centre between 1999 and 2008. The mean total costs for revision surgery in aseptic cases (n = 194) were £11 897 (sd 4629), for septic revision (n = 76) £21 937 (sd 10 965), for peri-prosthetic fracture (n = 24) £18 185 (sd 9124), and for dislocation (n = 11) £10 893 (sd 5476). Surgery for deep infection and peri-prosthetic fracture was associated with longer operating times, increased blood loss and an increase in complications compared to revisions for aseptic loosening. Total inpatient stay was also significantly longer on average (p < 0.001). Financial costs vary significantly by indication, which is not reflected in current National Health Service tariffs.
Performance Demands in Softball Pitching: A Comprehensive Muscle Fatigue Study.
Corben, Jeffrey S; Cerrone, Sara A; Soviero, Julie E; Kwiecien, Susan Y; Nicholas, Stephen J; McHugh, Malachy P
2015-08-01
Monitoring pitch count is standard practice in minor league baseball but not in softball because of the perception that fast-pitch softball pitching is a less stressful motion. To examine muscle fatigue after fast-pitch softball performances to provide an assessment of performance demand. Descriptive laboratory study. Bilateral strength measurements (handheld dynamometer) were made on 19 female softball pitchers (mean age [±SD], 15.2 ± 1.2 years) before and after pitching a game (mean number of pitches, 99 ± 21; mean innings pitched, 5 ± 1). A total of 20 tests were performed on the dominant and nondominant sides: forearm (grip, wrist flexion/extension, pronation/supination, elbow flexion/extension), shoulder (flexion, abduction/adduction, external/internal rotation, empty can test), scapula (middle/lower trapezius, rhomboid), and hip (hip flexion/extension, abduction/adduction). Fatigue (percentage strength loss) was categorized based on bilateral versus unilateral presentation using paired t tests: bilateral symmetric (significant on dominant and nondominant and not different between sides), bilateral asymmetric (significant on dominant and nondominant but significantly greater on dominant), unilateral asymmetric (significant on dominant only and significantly greater than nondominant), or unilateral equivocal (significant on dominant only but not different from nondominant). Bilateral symmetric fatigue was evident for all hip (dominant, 19.3%; nondominant, 15.2%) and scapular tests (dominant, 19.2%; nondominant, 19.3%). In general, shoulder tests exhibited bilateral asymmetric fatigue (dominant, 16.9%; nondominant, 11.6%). Forearm tests were more variable, with bilateral symmetric fatigue in the elbow flexors (dominant, 22.5%; nondominant, 19.2%), and wrist flexors (dominant, 21.6%; nondominant, 19.0%), bilateral asymmetric fatigue in the supinators (dominant, 21.8%; nondominant, 15.5%), unilateral asymmetric fatigue in the elbow extensors (dominant, 22.1%; nondominant, 11.3%), and unilateral equivocal fatigue in the pronators (dominant, 18.8%; nondominant, 15.2%) and grip (dominant, 11.4%; nondominant, 6.6%). The mean (±SD) pitch velocity was 49 ± 4 mph, with a small loss of velocity from the first to last inning pitched (3.4% ± 5.0%, P < .01). Fast-pitch softball pitching resulted in profound bilateral fatigue in the hip and scapular muscles, with more selective fatigue in the shoulder and arm muscles. These findings emphasize the importance of strength in the proximal musculature to provide a stable platform for the arm to propel the ball. © 2015 The Author(s).
Moussa, Mohamed E.; Esposito, Christina I.; Elpers, Marcella E.; Wright, Timothy M.; Padgett, Douglas E.
2014-01-01
The aims of this study were to assess damage on the surface of retrieved oxidized zirconium metal (OxZr) femoral heads, to measure surface roughness of scratches, and to evaluate the extent of surface effacement using scanning electron microscopy (SEM). Ceramic zirconia-toughened alumina (ZTA) heads were analyzed for comparison. OxZr femoral heads explanted for recurrent dislocation had the most severe damage (p<0.001). The median surface roughness of damaged OxZr femoral heads was 1.49μm, compared to 0.084μm for damaged ZTA heads and 0.052μm for undamaged OxZr (p<0.001). This may be of clinical concern because increased surface roughness has the potential to increase the wear of polyethylene liners articulating against these OxZr heads in THA. PMID:25443362
Jones, Kevin B; Griffin, Anthony M; Chandrasekar, Coonoor R; Biau, David; Babinet, Antoine; Deheshi, Benjamin; Bell, Robert S; Grimer, Robert J; Wunder, Jay S; Ferguson, Peter C
2011-11-01
Functional outcomes following oncologic total femoral endoprosthetic reconstruction (TFR) are lacking. We compared patient-oriented functional results of TFRs to proximal femur and distal femur reconstructions (PFR and DFR). We also compared function and complications with regard to knee and hip componentry. Fifty-four TFR patients were identified from three institutional prospective databases. Forty-one had fixed- and 13 had rotating-hinge knees, 37 hemiarthroplasty and 17 total hip arthroplasty componentry. Toronto Extremity Salvage Scores (TESS) for n = 27 were compared between groups and to cohorts of PFR (n = 31) and DFR (n = 85) patients using the Mann-Whitney U-test. Follow-up averaged 4 years. Mechanical complications included five hip dislocations and one femoral malrotation. Four dislocations were in fixed-hinge implants, all in those lacking abductor reattachment. TESS averaged 69.3 ± 17.8, statistically decreased from DFR (P = 0.002) and PFR patients (P = 0.036). No significant differences were detected between patients in the fixed-hinge (n = 18) and rotating-hinge (n = 9) groups (P = 0.944), or total hip (n = 8) and hemiarthroplasty (n = 19) groups (P = 0.633). TFR is reserved for extreme cases of limb salvage, portending a poor prognosis overall. Function reflects additive impairments from PFR and DFR. TFR outcomes differ little with rotating- or fixed-hinge, total hip or hemiarthroplasty implants. Copyright © 2011 Wiley Periodicals, Inc.
Snijders, Thom E; Willemsen, Koen; van Gaalen, Steven M; Castelein, Rene M; Weinans, Harrie; de Gast, Arthur
2018-05-01
Dislocation is one of the main reasons for revision of total hip arthroplasty but dislocation rates have not changed in the past decades, compromising patients' well-being. Acetabular cup orientation plays a key role in implant stability and has been widely studied. This article investigates whether there is a consensus on optimal cup orientation, which is necessary when using a navigation system. A systematic search of the literature in the PubMed, Embase and Cochrane databases was performed (March 2017) to identify articles that investigated the direct relationship between cup orientation and dislocation, including a thorough evaluation of postoperative cup orientation assessment methods. Twenty eight relevant articles evaluating a direct relation between dislocation and cup orientation could not come to a consensus. The key reason is a lack of uniformity in the assessment of cup orientation. Cup orientation is assessed with different imaging modalities, different methodologies, different definitions for inclination and anteversion, several reference planes and distinct patient positions. All available studies lack uniformity in cup orientation assessment; therefore it is impossible to reach consensus on optimal cup orientation. Using navigation systems for placement of the cup is inevitably flawed when using different definitions in the preoperative planning, peroperative placement and postoperative evaluation. Further methodological development is required to assess cup orientation. Consequently, the postoperative assessment should be uniform, thus differentiating between anterior and posterior dislocation, use the same definitions for inclination and anteversion with the same reference plane and with the patient in the same position.
Innovations in the management of hip fractures.
Teasdall, Robert D; Webb, Lawrence X
2003-08-01
Hip fractures include fractures of the head, neck, intertrochanteric, and subtrochanteric regions. Head fractures commonly accompany dislocations. Neck fractures and intertrochanteric fractures occur with greatest frequency in elderly patients with a low bone mineral density and are produced by low-energy mechanisms. Subtrochanteric fractures occur in a predominantly strong cortical osseous region that is exposed to large compressive stresses. Implants used to address these fractures must accommodate significant loads while the fractures consolidate. Complications secondary to hip fractures produce significant morbidity and include infection, nonunion, malunion, decubitus ulcers, fat emboli, deep venous thrombosis, pulmonary embolus, pneumonia, myocardial infarction, stroke, and death.
Dissociation of modular total hip arthroplasty at the neck-stem interface without dislocation.
Kouzelis, A; Georgiou, C S; Megas, P
2012-12-01
Modular femoral and acetabular components are now widely used, but only a few complications related to the modularity itself have been reported. We describe a case of dissociation of the modular total hip arthroplasty (THA) at the femoral neck-stem interface during walking. The possible causes of this dissociation are discussed. Successful treatment was provided with surgical revision and replacement of the modular neck components. Surgeons who use modular components in hip arthroplasties should be aware of possible early complications in which the modularity of the prostheses is the major factor of failure.
Doherty, Cailbhe; Bleakley, Chris; Hertel, Jay; Caulfield, Brian; Ryan, John; Sweeney, Kevin; Delahunt, Eamonn
2015-07-01
This investigation combined measures of inter-joint coordination and stabilometry to evaluate eyes-open (condition 1) and eyes-closed (condition 2) static unilateral stance performance in a group of participants with an acute, first-time lateral ankle sprain injury in comparison to a control group. Sixty-six participants with an acute first-time lateral ankle sprain and 19 non-injured controls completed three 20-second unilateral stance task trials in conditions 1 and 2. An adjusted coefficient of multiple determination statistic was used to compare stance limb 3-D kinematic data for similarity in the aim of establishing patterns of inter-joint coordination for these groups. Between-group analyses revealed significant differences in stance limb inter-joint coordination strategies for conditions 1 and 2. Injured participants displayed increases in ankle-hip linked coordination compared to controls in condition 1 (sagittal/frontal plane: 0.12 [0.09] vs 0.06 [0.04]; η(2)=.16) and condition 2 (sagittal/frontal plane: 0.18 [0.13] vs 0.08 [0.06]; η(2)=0.37). Participants with acute first-time lateral ankle sprain exhibit a hip-dominant coordination strategy for static unilateral stance compared to non-injured controls. Copyright © 2015 Elsevier Ltd. All rights reserved.
Acker, A; Fischer, J-F; Aminian, K; Lécureux, E; Jolles, B M
2017-02-01
Rates of dislocation following primary total hip arthroplasty (THA) vary from 0.5 to 10%. Dual-mobility cups in THA demonstrate increased stability. Clinical outcomes following THA with dual-mobility cups have been reported, but gait has not been assessed. Therefore we performed a retrospective case control study to answer: (1) is gait better in patients following THA with a dual-mobility cup than in frail, elderly patients of the same age? (2) Are clinical outcomes better in patients following THA with a dual-mobility cup than in frail, elderly patients? (3) What is the dislocation rate following THA with a dual-mobility cup? We hypothesized that patients who underwent THA with a dual-mobility cup have a better gait compared to frail, elderly patients of the same age. Twenty patients (22 hips), mean age 79.9±7.7 (range, 62.3-88.3) years were assessed in this retrospective case-control series 5.6±1.4 (range: 4.1-8.8) years following dual-mobility cup THA. A reference group consisted of 72 "frail elderly" patients in a rehabilitation hospital for health problems unrelated to the lower limb, with no lower limb surgery or neurological conditions. Temporal and spatial gait performance were measured with four miniature gyroscopes, mounted on each thigh and calf, while patients walked freely along a 30m corridor. Harris Hip Score, WOMAC, radiological outcomes, and dislocation rate were determined. All gait parameters were better in the dual-mobility group compared to the frail elderly group. The dual-mobility group had a higher cadence (100.3 steps/minute versus 75.6 steps/minute), shorter (relative to gait cycle time) stance (61.6% versus 67.8%), shorter (relative to gait cycle time) double stance (23.3% versus 36.0%), longer stride (1.13m versus 0.80m), and faster walking speed (0.96m/s versus 0.52m/s). Range of motion of the shank, thigh and knee were better in the dual-mobility group. Harris Hip Score was 87.6±13.9 (range 51-100) and WOMAC score was 11.3±12.1 (range 0-34) in the THA group. We observed no dislocations. Gait patterns five years following THA with the dual-mobility cup were better or comparable to published study populations. III, retrospective case-control series. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Feasibility and reliability of using an exoskeleton to emulate muscle contractures during walking.
Attias, M; Bonnefoy-Mazure, A; De Coulon, G; Cheze, L; Armand, S
2016-10-01
Contracture is a permanent shortening of the muscle-tendon-ligament complex that limits joint mobility. Contracture is involved in many diseases (cerebral palsy, stroke, etc.) and can impair walking and other activities of daily living. The purpose of this study was to quantify the reliability of an exoskeleton designed to emulate lower limb muscle contractures unilaterally and bilaterally during walking. An exoskeleton was built according to the following design criteria: adjustable to different morphologies; respect of the principal lines of muscular actions; placement of reflective markers on anatomical landmarks; and the ability to replicate the contractures of eight muscles of the lower limb unilaterally and bilaterally (psoas, rectus femoris, hamstring, hip adductors, gastrocnemius, soleus, tibialis posterior, and peroneus). Sixteen combinations of contractures were emulated on the unilateral and bilateral muscles of nine healthy participants. Two sessions of gait analysis were performed at weekly intervals to assess the reliability of the emulated contractures. Discrete variables were extracted from the kinematics to analyse the reliability. The exoskeleton did not affect normal walking when contractures were not emulated. Kinematic reliability varied from poor to excellent depending on the targeted muscle. Reliability was good for the bilateral and unilateral gastrocnemius, soleus, and tibialis posterior as well as the bilateral hamstring and unilateral hip adductors. The exoskeleton can be used to replicate contracture on healthy participants. The exoskeleton will allow us to differentiate primary and compensatory effects of muscle contractures on gait kinematics. Copyright © 2016 Elsevier B.V. All rights reserved.
Total hip arthroplasty performed in patients with residual poliomyelitis: does it work?
Yoon, Byung-Ho; Lee, Young-Kyun; Yoo, Jeong Joon; Kim, Hee Joong; Koo, Kyung-Hoi
2014-03-01
Patients with residual poliomyelitis can have advanced degenerative arthritis of the hip in the paralytic limb or the nonparalytic contralateral limb. Although THA is a treatment option for some of these patients, there are few studies regarding THA in this patient population. We therefore reviewed a group of patients with residual poliomyelitis who underwent cementless THA on either their paralytic limb or nonparalytic limb to assess (1) Harris hip scores, (2) radiographic results, including implant loosening, (3) complications, including dislocation, and (4) limb length discrepancy after recovery from surgery. From January 2000 to December 2009, 10 patients with residual poliomyelitis (10 hips, four paralytic limbs and six nonparalytic contralateral limbs) underwent THA using cementless prostheses. Harris hip scores, complications, and leg length discrepancy were determined by chart review, and confirmed by questionnaire and examination; radiographs were reviewed by two observers for this study. Followup was available for all 10 patients at a minimum of 3 years (median, 7 years; range, 3.4-13 years). Surgery was done at the same side of the paralytic limb in four hips and contralateral to the paralytic limb in six. All patients had pain relief and improvement in function; the Harris hip score improved from mean of 68 preoperatively to 92 at last followup (p = 0.043). However, only three patients had complete pain relief. One hip dislocated, which was treated successfully with closed reduction and a hip spica cast for 2 months. There was no loosening or osteolysis in this series. Leg length discrepancy improved after the index operation, but only in the THAs performed in the paralytic limbs. Cementless THA may be suitable for painful hips in adult patients with residual poliomyelitis. Nonetheless, these patients should be informed of the possibility of mild residual pain and persistent leg length discrepancy, particularly patients whose THA is performed on the limb that was not affected by polio (ie, the nonparalytic contralateral limb). Level IV, therapeutic study. See the Instructions for Authors for a complete description of levels of evidence.
Maranho, Daniel Augusto; Donati, Felipe Nunes; Dalto, Vitor Faeda; Nogueira-Barbosa, Marcello Henrique
2017-09-01
To evaluate the evolution of the ultrasonographic pubo-femoral distance (PFD) before and after Pavlik harness treatment for developmental dysplasia of the hip (DDH) in newborns. Twenty-five patients (16.7 ± 10.4 days; 19 females, six males) diagnosed with DDH and treated using the Pavlik harness were included. Eighteen patients had bilateral, and seven unilateral DDH, with a total of 43 dysplastic hips. The seven non-dysplastic hips in unilateral cases were used for comparison. The PFD was measured in the coronal and axial planes with the hip flexed to approximately 90°, before and after an average of 93 days of treatment. The femoral head coverage was assessed in the coronal plane, and correlated with PFD values. In dysplastic hips, the mean PFD decreased from 6.1 ± 1.8 mm to 3.0 ± 0.7 mm in the axial (adjusted difference, 2.9 mm; p < 0.01), and from 5.9 ± 2.0 to 3.0 ± 0.6 mm in the coronal plane (adjusted difference 2.7 mm; p < 0.01). The femoral head coverage increased from 30.8 to 62.1%, and the mean differences of femoral head coverage and PFD were significantly correlated (p < 0.001). There was no difference between treated dysplastic and non-dysplastic hips. There was high intra- and inter-observer agreement for PFD measurements. The PFD decreased significantly after DDH treatment using the Pavlik harness in newborns, and showed significant correlation with the femoral head coverage improvement. PFD might be a reliable tool for monitoring DDH treatment in newborns treated using the Pavlik harness.
Blizzard, Daniel J; Penrose, Colin T; Sheets, Charles Z; Seyler, Thorsten M; Bolognesi, Michael P; Brown, Christopher R
2017-08-01
Ankylosing spondylitis (AS) is a chronic autoimmune spondyloarthropathy that primarily affects the axial spine and hips. Progressive disease leads to pronounced spinal kyphosis, positive sagittal balance, and altered biomechanics. The purpose of this study is to determine the complication profile of patients with AS undergoing total hip arthroplasty (THA). The Medicare sample was searched from 2005 to 2012 yielding 1006 patients with AS who subsequently underwent THA. Risk ratios (RRs) with 95% confidence intervals (CIs) were calculated for 90-day, 2-year, and the final postoperative follow-up for complications including hip dislocation, periprosthetic fracture, wound complication, revision THA, and postoperative infection. Compared to controls, AS patients had an RR of 2.50 (CI, 1.04-5.99) of THA component breakage at 90-days post-operatively and 1.99 (CI, 1.10-3.59) at 2-years. The RR of periprosthetic hip dislocation was elevated at 90 days (1.44; CI, 0.93-2.22) and significantly increased at 2-years (1.67; CI, 1.25-2.23) and overall follow-up (1.49; CI, 1.14-1.93). Similarly, the RR for THA revision was elevated at 90-days (1.46; CI, 0.97-2.18) and significantly increased at 2-years (1.69; CI, 1.33-2.14) and overall follow-up (1.51; CI, 1.23-1.85). Patients with AS are at increased risk for complications after THA. Altered biomechanics from a rigid, kyphotic spine place increased demand on the hip joints. The elevated perioperative and postoperative risks should be discussed preoperatively, and these patients may require increased preoperative medical optimization as well as possible changes in component selection and position to compensate for altered spinopelvic biomechanics. Copyright © 2017 Elsevier Inc. All rights reserved.
Accuracy of femoral templating in reproducing anatomical femoral offset in total hip replacement.
Davies, H; Foote, J; Spencer, R F
2007-01-01
Restoration of hip biomechanics is a crucial component of successful total hip replacement. Preoperative templating is recommended to ensure that the size and orientation of implants is optimised. We studied how closely natural femoral offset could be reproduced using the manufacturers' templates for 10 femoral stems in common use in the UK. A series of 23 consecutive preoperative radiographs from patients who had undergone unilateral total hip replacement for unilateral osteoarthritis of the hip was employed. The change in offset between the templated position of the best-fitting template and the anatomical centre of the hip was measured. The templates were then ranked according to their ability to reproduce the normal anatomical offset. The most accurate was the CPS-Plus (Root Mean Square Error 2.0 mm) followed in rank order by: C stem (2.16), CPT (2.40), Exeter (3.23), Stanmore (3.28), Charnley (3.65), Corail (3.72), ABG II (4.30), Furlong HAC (5.08) and Furlong modular (7.14). A similar pattern of results was achieved when the standard error of variability of offset was analysed. We observed a wide variation in the ability of the femoral prosthesis templates to reproduce normal femoral offset. This variation was independent of the seniority of the observer. The templates of modern polished tapered stems with high modularity were best able to reproduce femoral offset. The current move towards digitisation of X-rays may offer manufacturers an opportunity to improve template designs in certain instances, and to develop appropriate computer software.
Unplanned hip arthroplasty imposes clinical and cost burdens on treating institutions.
Kamath, Atul F; Austin, Daniel C; Derman, Peter B; Israelite, Craig L
2013-12-01
Emergent surgery has been shown to be a risk factor for perioperative complications. Studies suggest that patient morbidity is greater with an unplanned hip arthroplasty, although it is controversial whether unplanned procedures also result in higher patient mortality. The financial impact of these procedures is not fully understood, as the costs of unplanned primary hip arthroplasties have not been studied previously. We asked: (1) What are the institutional costs associated with unplanned hip arthroplasties (primary THA, hemiarthroplasty, revision arthroplasty, including treatment of periprosthetic fractures, dislocations, and infections)? (2) Does timing of surgery (urgent/unplanned versus elective) influence perioperative outcomes such as mortality, length of stay, or need for advanced care? (3) What diagnoses are associated with unplanned surgery and are treated urgently most often? (4) Do demographics and insurance status differ between admission types (unplanned versus elective hip arthroplasty)? We prospectively followed all 419 patients who were admitted to our Level I trauma center in 2011 for procedures including primary THA, hemiarthroplasty, and revision arthroplasty, including the treatment of periprosthetic fractures, dislocations, and infections. Fifty-seven patients who were treated urgently on an unplanned basis were compared with 362 patients who were treated electively. Demographics, admission diagnoses, complications, and costs were recorded and analyzed statistically. Median total costs were 24% greater for patients admitted for unplanned hip arthroplasties (USD 18,206 [USD 15,261-27,491] versus USD 14,644 [USD 13,511-16,309]; p < 0.0001) for patients admitted for elective arthroplasties. Patients with unplanned admissions had a 67% longer median hospital stay (5 days [range, 4-9 days] versus 3 days [range, 3-4 days]; p < 0.0001) for patients with elective admissions. Mortality rates were equivalent between groups (p = 1.0). Femoral fracture (p < 0.0001), periprosthetic fracture (p = 0.01), prosthetic infection (p = 0.005), and prosthetic dislocation (p < 0.0001) were observed at higher rates in the patients with unplanned admissions. These patients were older (p = 0.04), less likely to have commercial insurance (p < 0.0001), more likely to be transferred from another institution (p < 0.0001), and more likely to undergo a revision procedure (p < 0.0001). Unplanned arthroplasty and urgent surgery are associated with increased financial and clinical burdens, which must be accounted for when considering bundled quality and reimbursement measures for these procedures.
Orthopaedic manifestations of campomelic dysplasia.
Khoshhal, Khalid; Letts, R Mervyn
2002-08-01
Campomelic dysplasia is a rare form of congenital dwarfism associated with potentially fatal respiratory insufficiency. There are several types of campomelic dysplasia; however, it is characterized by the presence of anteriorly bowed tibias with cutaneous dimpling, anterolaterally bowed femurs, thoracic kyphoscoliosis, hypoplastic scapulas, and absence or delayed ossification of thoracic pedicles. With improving treatment of respiratory insufficiency, the survival rate of affected infants has increased, thereby necessitating treatment of the musculoskeletal malformations to prevent additional morbidity. In an attempt to increase awareness of the presentation of infants with campomelic dysplasia and to emphasize the difficulties of treating associated developmental dislocation of the hip early, the current authors report the case of a 2-year-old girl with campomelic dysplasia who was treated for dislocation of the right hip. The postoperative course of this child was complicated seriously by several apneic episodes secondary to tracheobronchial malacia for which she required admission to the pediatric intensive care unit.
High-quality vertical light emitting diodes fabrication by mechanical lift-off technique
NASA Astrophysics Data System (ADS)
Tu, Po-Min; Hsu, Shih-Chieh; Chang, Chun-Yen
2011-10-01
We report the fabrication of mechanical lift-off high quality thin GaN with Hexagonal Inversed Pyramid (HIP) structures for vertical light emitting diodes (V-LEDs). The HIP structures were formed at the GaN/sapphire substrate interface under high temperature during KOH wet etching process. The average threading dislocation density (TDD) was estimated by transmission electron microscopy (TEM) and found the reduction from 2×109 to 1×108 cm-2. Raman spectroscopy analysis revealed that the compressive stress of GaN epilayer was effectively relieved in the thin-GaN LED with HIP structures. Finally, the mechanical lift-off process is claimed to be successful by using the HIP structures as a sacrificial layer during wafer bonding process.
Anai, Takanobu; Urata, Kenichirou; Mori, Atsue; Miyazaki, Fumiko; Okamoto, Sumiaki
2013-01-01
Transient osteoporosis of the hip (TOH) in pregnancy is characterized by severe pain in unilateral or bilateral hips and has been diagnosed as localized osteopenia. However, we evaluated a case of unilateral TOH with generalized profound osteoporosis involving both the hips and the lumbar vertebrae by dual-energy X-ray absorptiometry. The diagnosis was based on the clinical course and confirmed by magnetic resonance imaging. Three-dimensional helical computed tomography (3D-CT), which has not been used in patients with TOH, revealed a markedly thin bilateral proximal femoral cortex, particularly in the symptomatic femoral head. Despite the difference in the severity of bone destruction between the two femora, they both showed the same pattern of damage on 3D-CT. Furthermore, despite continuing treatment with the same dose of alendronate and calcitriol, a high rate of bone mineral density gain, involving both the femora and lumbar vertebrae, was limited to the early postpartum months. A majority of reported female patients with TOH are pregnant. Thus, the association between TOH and pregnancy was not considered to be fortuitous, and chemical or hormonal factors related to pregnancy may play an etiologic role in this disease. The possible etiologies of TOH in pregnancy are also discussed. © 2013 S. Karger AG, Basel.
Bieler, Theresa; Magnusson, Stig Peter; Christensen, Helle Elisabeth; Kjaer, Michael; Beyer, Nina
2017-07-01
To investigate between-leg differences in hip and thigh muscle strength and leg extensor power in patients with unilateral hip osteoarthritis. Further, to compare between-leg differences in knee extensor strength and leg extensor power between patients and healthy peers. Seventy-two patients (60-87 years) with radiographic and symptomatic hip osteoarthritis not awaiting hip replacement and 35 healthy peers (63-82 years) were included. Hip and thigh muscle strength and leg extensor power were measured in patients and knee extensor strength and leg extensor power in healthy. The symptomatic extremity in patients was significantly (p < 0.05, paired t-test) weaker compared with the non-symptomatic extremity for five hip muscles (8-17%), knee extensors (11%) and leg extensor power (19%). Healthy older adults had asymmetry in knee extensor strength (6%, p < 0.05) comparable to that found in patients, but had no asymmetry in leg extensor power. Patients had generalized weakening of the affected lower extremity and numerically the largest asymmetry was evident for leg extensor power. In contrast, healthy peers had no asymmetry in leg extensor power. These results indicate that exercise interventions focusing on improving leg extensor power of the symptomatic lower extremity and reducing asymmetry may be beneficial for patients with hip osteoarthritis. Implications for Rehabilitation Even in patients with mild symptoms not awaiting hip replacement a generalized muscle weakening of the symptomatic lower extremity seems to be present. Between-leg differences in leg extensor power (force × velocity) appears to be relatively large (19%) in patients with unilateral hip osteoarthritis in contrast to healthy peers who show no asymmetry. Compared to muscle strength the relationship between functional performance and leg extensor power seems to be stronger, and more strongly related to power of the symptomatic lower extremity. Our results indicate that exercise interventions focusing on improving leg extensor power of the symptomatic lower extremity and reducing asymmetry may be beneficial for patients with mild symptoms not awaiting hip replacement.
Design of a hip prosthetic tribometer based on salat gait cycle
NASA Astrophysics Data System (ADS)
Towijaya, T.; Ismail, R.; Jamari, J.
2017-01-01
Indonesia is the country with the largest muslim population in the world, most of the inhabitants do salat every day. THR (Total Hip Replacement) patients are prohibited from doing salat in normal gait. It leads to the damage of the hip joint prostheses due to impingement and dislocation.This paper reports the design of a pin-on-ring tribometer which is used to measure and analyze the wear volume and the impingement of hip joint prostheses during salat. The modifications of the femoral head and acetabular cup holder are performed to design the reciprocating motion for the movement of the hip prostheses. The interesting finding of the present research is a new mechanism of linked-bar which leads to the feasibility of the measurement of the wear volume and the impingement for THR patients during salat.
Fabio, Costa; Romualdo, Del Buono; Eugenio, Agrò Felice; Vittoradolfo, Tambone; Massimiliano, Vitali Andrea; Giovanna, Ricci
2017-01-01
Spinal anaesthesia is the most preffered anesthesia technique for total hip replacement, and its complications range from low entity (insignificant) to life threatening. The incidence of neurologic complications after neuraxial anaesthesia is not perfectly clear, although there are several described cases of spinal cord ischaemia. We present a case of unilateral T8–T11 spinal cord ischaemia following L2–L3 spinal anaesthesia for total hip replacement. Magnetic resonance imaging showed a hyperintense T8–T11 signal alteration on the leftside of paramedian spinal cord. A temporal epidemiologic linkage between the damage and the surgery seems to be present. The injury occurred without anatomical proximity between the injury site and the spinal needle entry site. This may be due to multiple contributing factors, each of them is probably not enough to determine the damage by itself; however, acting simultaneously, they could have been responsible for the complication. The result was unpredictable and unavoidable and was caused by unforeseeable circumstances and not by inadequate medical practice. PMID:28439446
Tong, Kuang; Zhang, Yuanzhi; Zhang, Sheng; Yu, Bin
2013-06-01
To provide an accurate method for osteotomy in the treatment of developmental dysplasia of the hip with steel osteotomy by three-dimensional reconstruction and Reverse Engineering technique. Between January 2011 and December 2012, 13 children with developmental dysplasia of the hip underwent steel osteotomy. 3D CT scan pelvic images were obtained and transferred via a DICOM network into a computer workstation to construct 3D models of the hip using Materialise Mimics 14.1 software in STL format. These models were imported into Imageware 12.0 software for steel osteotomy simulation until a stable hip was attained in the anatomical position for dislocation or subluxation of the hip in older children. The osteotomy navigational templates were designed according to the anatomical features after a stable hip was reconstructed. These navigational templates were manufactured using a rapid prototyping technique. The reconstruction hips in these children show good matching property and acetabulum cover. The computer-aided design of osteotomy template provides personalized and accurate solutions in the treatment of developmental dysplasia of the hip with steel osteotomy in older children.
Primary total hip replacement for displaced subcapital fractures of the femur.
Taine, W H; Armour, P C
1985-03-01
The management of displaced subcapital fracture of the hip is still controversial because of the high incidence of complications after internal fixation or hemiarthroplasty. To avoid some of these complications we have used primary total hip replacement for independently mobile patients over 65 years of age. A total of 163 cases, operated on over four years, have been reviewed. There were relatively more dislocations after operation for fracture than after total replacement for arthritis, and these were associated with a posterior approach to the hip. Only seven revision operations have been required. Of 57 patients who were interviewed an average of 42 months after replacement, 62% had excellent or good results as assessed by the Harris hip score. All the others had major systemic disease which affected their assessment. This inadequacy of current systems of hip assessment is discussed. It is concluded that total hip replacement is the best management for a selected group of patients with this injury, and that further prospective studies are indicated.
Instability of total hip replacement: A clinical study and determination of its risk factors.
Ezquerra-Herrando, L; Seral-García, B; Quilez, M P; Pérez, M A; Albareda-Albareda, J
2015-01-01
To determine the risk factors associated with prosthetic dislocation and simulate a finite element model to determine the safe range of movement of various inclination and anteversion cup positions. Retrospective Case Control study with 46 dislocated patients from 1994 to 2011. 83 randomly selected patients. Dislocation risk factors described in the literature were collected. A prosthetic model was simulated using finite elements with 28, 32, 36 mm heads, and a 52 mm cup. Acetabular position was 25°, 40°, and 60° tilt and with 0°, 15° and 25° anteversion. In extension of 0° and flexion of 90°, internal and external rotation was applied to analyze the range of movement, maximum resisting moment, and stress distribution in the acetabulum to impingement and dislocation. There was greater dislocation in older patients (p=0.002). Higher dislocation in fractures than in osteoarthritis (p=0.001). Less anteversion in dislocated patients (p=0.043). Longer femoral neck in dislocated patients (p=0.002). Finite element model: lower dislocation when there is more anteversion, tilt and bigger femoral heads. Advanced age and fractures are the major risk factors for dislocation. "Safe zone" of movement for dislocation avoidance is 40°-60° tilt and 15°-25° anteversion. Both the defect and excess of soft tissue tension predispose to dislocation. Bigger femoral heads are more stable. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.
Closed bone graft epiphysiodesis for avascular necrosis of the capital femoral epiphysis.
Thompson, George H; Lea, Ethan S; Chin, Kenneth; Liu, Raymond W; Son-Hing, Jochen P; Gilmore, Allison
2013-07-01
Avascular necrosis (AVN) of the capital femoral epiphysis (CFE) after an unstable slipped capital femoral epiphysis (SCFE), femoral neck fracture or traumatic hip dislocation can result in severe morbidity. Treatment options for immature patients with AVN are limited, including a closed bone graft epiphysiodesis (CBGE). However, it is unclear whether this procedure prevents AVN progression. We investigated whether early MRI screening and CBGE prevented the development of advanced AVN changes in the CFE and the rates of complications with this approach. We prospectively followed all 13 patients (seven boys, six girls) with unstable SCFEs (six patients), femoral neck fractures (five patients), and traumatic hip dislocations (two patients) and evidence of early AVN treated between 1984 and 2012. Mean age at initial injury was 12 years (range, 10-16 years). Nine of the 13 patients had followup of at least 2 years or until conversion to THA (mean, 4.5 years; range, 0.8-8.5 years), including two with unstable SCFEs, the five with femoral neck fractures, and the two with traumatic hip dislocations. All patients had technetium scans and/or MRI within 1 to 2 months of their initial injury (before CBGE) and all had evidence of early (Ficat 0) AVN. Patients were followed clinically and radiographically for AVN progression. Six of the nine hips did not develop typical clinical or radiographic evidence of AVN. These six patients have been followed 6.3 years (range, 4.3-9.1 years) from initial injury and 5.9 years (range, 3.8-8.5 years) from CBGE. The remaining three patients were diagnosed with AVN at periods ranging from 3 to 6 months after CBGE. Early recognition and treatment of AVN with a CBGE may alter the natural history of this complication. Level IV, therapeutic study. See Instructions for Authors for a complete description of levels of evidence.
Five to thirteen year results of a cemented dual mobility socket to treat recurrent dislocation.
Hamadouche, Moussa; Ropars, Mickael; Rodaix, Camille; Musset, Thierry; Gaucher, François; Biau, David; Courpied, Jean Pierre; Huten, Denis
2017-03-01
Dual mobility (DM) socket has been associated with a low rate of dislocation following both primary and revision total hip arthroplasty (THA). However, little is known about the long-term efficiency of DM in the treatment of THA instability. The purpose of this retrospective study was to evaluate the outcome of a cemented DM socket to treat recurrent dislocation after a minimum of five year follow-up. The series included 51 patients with a mean age of 71.3 ± 11.5 (range, 41-98) years presenting with recurrent dislocation (mean 3.3). A single DM socket design was used consisting of a stainless steel outer shell with grooves with a highly polished inner surface articulating with a mobile polyethylene component. The femoral head was captured in the polyethylene component using a snap-fit type mechanism, the latter acting as a large unconstrained head inside the metal cup. At the minimum five year follow-up evaluation, 18 of the 51 patients deceased at a mean of 4.8 ± 2.3 years, three were lost to follow-up at a mean of 1.4 years, seven had been revised at a mean of 4.7 ± 3.1 years (range, 1.5-9.1), and the remaining 23 were still alive and did not have revision at a mean of 8.2 ± 2.4 years (range, 5-13 years). Of the seven revision, three were performed for further episodes of dislocation (at the large bearing for one patient and intra-prosthetic for two patients) after a mean 5.9 ± 2.9 years (range, 2.7-9.1), whereas two were performed for late sepsis and two for aseptic loosening of the acetabular component. Radiographic analysis did not reveal any further loosening on the acetabular side. The survival rate of the cup at ten years, using re-dislocation as the end-point, was 86.1 ± 8.4% (95% confidence interval, 69.7-100%). The survival rate of the cup at ten years, using revision for any reason as the end-point, was 75.2 ± 9.3% (95% confidence interval, 56.9-93.5%). A cemented dual mobility cup was able to restore hip stability in 94% of patients presenting with recurrent dislocating hips up to 13-year follow-up with none of the complications associated with constrained devices, as mechanical failure occurred in only 3.9% of the patients of this series. The overall reduced survival using revision for any reason as the end-point at ten years was related to this specific patients population that had various co-morbidities.
Socket position determines hip resurfacing 10-year survivorship.
Amstutz, Harlan C; Le Duff, Michel J; Johnson, Alicia J
2012-11-01
Modern metal-on-metal hip resurfacing arthroplasty designs have been used for over a decade. Risk factors for short-term failure include small component size, large femoral head defects, low body mass index, older age, high level of sporting activity, and component design, and it is established there is a surgeon learning curve. Owing to failures with early surgical techniques, we developed a second-generation technique to address those failures. However, it is unclear whether the techniques affected the long-term risk factors. We (1) determined survivorship for hips implanted with the second-generation cementing technique; (2) identified the risk factors for failure in these patients; and (3) determined the effect of the dominant risk factors on the observed modes of failure. We retrospectively reviewed the first 200 hips (178 patients) implanted using our second-generation surgical technique, which consisted of improvements in cleaning and drying the femoral head before and during cement application. There were 129 men and 49 women. Component orientation and contact patch to rim distance were measured. We recorded the following modes of failure: femoral neck fracture, femoral component loosening, acetabular component loosening, wear, dislocation, and sepsis. The minimum followup was 25 months (mean, 106.5 months; range, 25-138 months). Twelve hips were revised. Kaplan-Meier survivorship was 98.0% at 5 years and 94.3% at 10 years. The only variable associated with revision was acetabular component position. Contact patch to rim distance was lower in hips that dislocated, were revised for wear, or were revised for acetabular loosening. The dominant modes of failure were related to component wear or acetabular component loosening. Acetabular component orientation, a factor within the surgeon's control, determines the long-term success of our current hip resurfacing techniques. Current techniques have changed the modes of failure from aseptic femoral failure to wear or loosening of the acetabular component. Level III, prognostic study. See Guidelines for Authors for a complete description of levels of evidence.
Li, Xigong; Sun, Junying; Lin, Xiangjin; Xu, Sanzhong; Tang, Tiansi
2013-06-01
The authors describe a modified double chevron subtrochanteric shortening osteotomy combined with cementless total hip arthroplasty for Crowe type-IV hip dysplasia. Shortening the femur allows to relax the shortened musculature. This operation was performed in 18 patients (22 hips) between January 2000 and February 2006. The mean follow-up period was 5.6 years (range: 3 to 8 years). The mean amount of femoral subtrochanteric shortening was 38 mm (range: 25 to 60 mm). The mean Harris hip score improved from 47 (range: 35 to 65) preoperatively to 88 points (range: 75 to 97) at final follow-up. The Trendelenburg sign was corrected from positive to negative in 12 of 22 hips. No acetabular or femoral components loosened or required revision during the follow-up period. All osteotomy sites healed in 3 to 6 months without complications. Cementless total hip arthroplasty using the modified double chevron subtrochanteric osteotomy provided good short- to midterm results in all 22 Crowe type-IV hip dislocations. Moreover, it restored the anatomic hip center and the limb length, which contributed to correction of the preoperative limp.
An update on surgical approaches in hip arthoplasty: lateral versus posterior approach.
Mukka, Sebastian S; Sayed-Noor, Arkan S
2014-10-02
In this update we searched the literature about the outcome of the lateral versus posterior approach in hip arthoplasty for osteoarthritis (OA) and femoral neck fracture (FNF) patients. The available evidence shows that the use of posterior approach in OA patients is associated with lower mortality and better functional outcome while the use of lateral approach in FNF patients gives lower dislocation rate. We recommend therefore the use of posterior approach in OA patients and lateral approach in FNF patients.
[Total hip arthroplasty through anterior "minimal invasive" approach].
Moerenhout, Kevin G; Cherix, Stéphane; Rüdiger, Hannes A
2012-12-19
Total hip replacement has seen a tremendous development and has become one of the most successful surgical interventions in orthopaedics. While during the first decades of development of total hip arthroplasty the fixation of the implant into the bone was the main concern, the focus has shifted towards surgical technique and soft tissue handling. In order to avoid permanent soft tissue damage, muscular dysfunction and concerns in regards to cosmetics, minimal invasive and anatomic approaches have been developed. We here provide a short overview on various methods of total hip replacements and we describe our technique through a minimal invasive direct anterior approach. While muscle and nerve damage is minimal, this technique allows for a rapid rehabilitation and is associated with an excellent functional outcome and a minimal risk for dislocation.
Reito, Aleksi; Elo, Petra; Nieminen, Jyrki; Puolakka, Timo; Eskelinen, Antti
2016-02-01
There are no international guidelines to define adverse reaction to metal debris (ARMD). Muscle fatty atrophy has been reported to be common in patients with failing metal-on-metal (MoM) hip replacements. We assessed whether gluteal muscle fatty atrophy is associated with elevated blood metal ion levels and pseudotumors. 263 consecutive patients with unilateral ASR XL total hip replacement using a posterior approach and with an unoperated contralateral hip were included in the study. All patients had undergone a standard screening program at our institution, including MRI and blood metal ion measurement. Muscle fatty atrophy was graded as being absent, mild, moderate, or severe in each of the gluteal muscles. The prevalence of moderate-to-severe gluteal muscle atrophy was low (12% for gluteus minimus, 10% for gluteus medius, and 2% for gluteus maximus). Muscle atrophy was neither associated with elevated blood metal ion levels (> 5 ppb) nor with the presence of a clear (solid- or mixed-type) pseudotumor seen in MRI. A combination of moderate-to-severe atrophy in MRI, elevated blood metal ion levels, and MRI-confirmed mixed or solid pseudotumor was rare. Multivariable regression revealed that "preoperative diagnosis other than osteoarthrosis" was the strongest predictor of the presence of fatty atrophy. Gluteal muscle atrophy may be a clinically significant finding with influence on hip muscle strength in patients with MoM hip replacement. However, our results suggest that gluteal muscle atrophy seen in MRI is not associated with either the presence or severity of ARMD, at least not in patients who have been operated on using the posterior approach.
Hauzeur, Jean-Philippe; Malaise, Michel; de Maertelaer, Viviane
2016-07-01
To study the clinical presentation of femoral head osteonecrosis (ONFH). Publications dedicated to this aspect of ONFH are rare. Our aim was to systematically collect and describe the clinical data. A prospective survey was conducted in a cohort of ONFH recruited from a dedicated clinic for osteonecrosis. The history of symptoms, medical management, and physical findings were obtained from 88 patients suffering from 125 ONFH. Subgroups were formed: bilateral versus unilateral ONFH, radiological stages 1-2 (pre-fractured) versus fractured stage 3 versus stage 4. ONFH was bilateral in 63 %, especially in corticosteroid users and in sickle-cell cases. These patients were younger but had similar BMIs compared to the unilateral cases. The pain was mechanical in 79 % of hips and inflammatory in 21 %. Acute pain at the onset was present in 55 % of hips. The localization of this pain was variable, including in the groin, the buttocks, or diffused in the lower limbs. A limp was present in 50 % of the patients, only when one hip was painful. The physical examination of the hip was normal in 31 %, especially in stages 1-2 (55 %). The diagnosis delay was 12 months, with inadequate medical management in 51 % of patients. In ONFH cases, no typical clinical pattern was found. The clinical presentation was very variable, sometimes having spine or knee symptoms with a normal physical examination of the hip. ONFH should be systematically suspected in cases of onset of pain in the pelvis, buttocks, groin, and lower limbs.
2011-01-01
Background Virtually all the articles in literature addressed only a specific type of dislocation. The aim of this review was to project a comprehensive understanding of the pathologic processes and management of all types of dislodgement of the head of the mandibular condyle from its normal position in the glenoid fossa. In addition, a new classification of temporomandibular joint dislocation was also proposed. Method and materials A thorough computer literature search was done using the Medline, Cochrane library and Embase database. Key words like temporo-mandibular joint dislocation were used for the search. Additional manual search was done by going through published home-based and foreign articles. Case reports/series, and original articles that documented the type of dislocation, number of cases treated in the series and original articles. Treatment done and outcome of treatment were included in the study. Result A total of 128 articles were reviewed out which 79 were found relevant. Of these, 26 were case reports, 17 were case series and 36 were original articles. 79 cases were acute dislocations, 35 cases were chronic protracted TMJ dislocations and 311 cases were chronic recurrent TMJ dislocations. Etiology was predominantly trauma in 60% of cases and other causes contributed about 40%. Of all the cases reviewed, only 4 were unilateral dislocation. Various treatment modalities are outlined in this report as indicated for each type of dislocation. Conclusion The more complex and invasive method of treatment may not necessarily offer the best option and outcome of treatment, therefore conservative approaches should be exhausted and utilized appropriately before adopting the more invasive surgical techniques. PMID:21676208
Akinbami, Babatunde O
2011-06-15
Virtually all the articles in literature addressed only a specific type of dislocation. The aim of this review was to project a comprehensive understanding of the pathologic processes and management of all types of dislodgement of the head of the mandibular condyle from its normal position in the glenoid fossa. In addition, a new classification of temporomandibular joint dislocation was also proposed. A thorough computer literature search was done using the Medline, Cochrane library and Embase database. Key words like temporo-mandibular joint dislocation were used for the search. Additional manual search was done by going through published home-based and foreign articles. Case reports/series, and original articles that documented the type of dislocation, number of cases treated in the series and original articles. Treatment done and outcome of treatment were included in the study. A total of 128 articles were reviewed out which 79 were found relevant. Of these, 26 were case reports, 17 were case series and 36 were original articles. 79 cases were acute dislocations, 35 cases were chronic protracted TMJ dislocations and 311 cases were chronic recurrent TMJ dislocations. Etiology was predominantly trauma in 60% of cases and other causes contributed about 40%. Of all the cases reviewed, only 4 were unilateral dislocation. Various treatment modalities are outlined in this report as indicated for each type of dislocation. The more complex and invasive method of treatment may not necessarily offer the best option and outcome of treatment, therefore conservative approaches should be exhausted and utilized appropriately before adopting the more invasive surgical techniques.
Complications in Hip Arthroscopy
Nakano, Naoki; Khanduja, Vikas
2016-01-01
Summary Background Recent developments in hip arthroscopic techniques and technology have made it possible in many cases to avoid open surgical dislocation for treating a variety of pathology in the hip. Although early reports suggest favourable results’ using hip arthroscopy and it has been shown to be a relatively safe procedure, complications do exist and can sometimes lead to significant morbidity. Methods This is a review article. The aim of this manuscript is to present the most frequent and/or serious complications that could occur at or following hip arthroscopy and some guidelines to avoid these complications. Conclusion Most complications of hip arthroscopy are minor or transient but serious complications can occur as well. A lot of complication e.g. acetabular labral puncture go unreported. Appropriate education and training, precise and meticulous surgical technique with correct instrumentation, the right indication in the right patient and adherence to advice from mentors and experienced colleagues are all essential factors for a successful outcome. Level of evidence: V. PMID:28066747
Anticipatory postural adjustments during lateral step motion in patients with hip osteoarthritis.
Tateuchi, Hiroshige; Ichihashi, Noriaki; Shinya, Masahiro; Oda, Shingo
2011-02-01
Patients with hip osteoarthritis (OA) have difficulty with mediolateral postural control. Since the symptom of hip OA includes joint pain, which mostly occurs upon initial movement, patients with hip OA might have disabling problems with movement initiation. This study aimed to identify the movement strategy during the anticipatory postural adjustments in the lateral step motion in patients with hip OA. We studied 18 female subjects with unilateral hip OA and 10 healthy subjects, and measured temporal, kinetic, and kinematic variables. Patients with hip OA required a longer duration of anticipation phase than the control subjects, the total duration of lateral stepping was not different between the groups. Displacement of the center of mass to the supporting (affected) side during the anticipation phase was not different between the two groups. These findings suggest that, in patients with hip OA, the center of mass slowly moved to the affected side. Furthermore, patients with hip OA showed greater shift of the trunk to the supporting side than did the control subjects. These movement characteristics might contribute to the achievement of both protection of the affected hip joint and quickness in the subsequent lateral step in patients with hip OA.
Large-diameter metal-on-metal total hip arthroplasty: dislocation infrequent but survivorship poor.
Lombardi, Adolph V; Berend, Keith R; Morris, Michael J; Adams, Joanne B; Sneller, Michael A
2015-02-01
Use of large-diameter metal-on-metal (MoM) articulations in THA increased, at least in part, because of the possibility of achieving improved joint stability and excellent wear characteristics in vitro. However, there have been subsequent concerning reports with adverse reactions to metal debris (ARMD), pseudotumors, and systemic complications related to metal ions. The purpose of this study was to determine at a minimum of 2 years' followup (1) the proportion of patients who experienced a dislocation; (2) the short-term survivorship obtained with these implants; (3) the causes of failure and the proportion of patients who developed ARMD; and (4) whether there were any identifiable risk factors for revision. We reviewed the results of 1235 patients who underwent 1440 large-diameter MoM primary THAs at our institution using two acetabular devices from a single manufacturer with minimum 2-year followup. Large-diameter MoM devices were used in 48% (1695 of 3567) of primary THAs during the study period. We generally used these implants in younger, more active, higher-demand patients, in patients considered at higher risk of instability, and in patients with adequate bone stock to achieve stable fixation without use of screws. Clinical records and radiographs were reviewed to determine the incidence and etiology of revision. Patients whose hips were revised were compared with those not revised to identify risk factors; Kaplan-Meier survivorship analysis was performed as was multivariate analysis to account for potential confounding variables when evaluating risk factors. Minimum followup was 2 years (average, 7 years; range, 2-12 years); complete followup was available in 85% of hips (1440 of 1695). Dislocation occurred in one hip overall (<1%; one of 1440). Kaplan-Meier analysis revealed survival free of component revision was 87% at 12 years (95% confidence interval, 84%-90%). The two most common indications for revision were ARMD (48%; 47 of 108 hips revised) and loosening or failure of ingrowth (31%; 34 of 108). Risk factors for component revision were younger age at surgery (relative risk [RR] 0.98 per each increased year; p=0.02), higher cup angle of inclination (RR 1.03 per each increased degree; p=0.04), and female sex (RR 1.67; p=0.03). Large-diameter MoM THAs are associated with a very low dislocation rate, but failure secondary to ARMD and loosening or lack of ingrowth occur frequently. Patients with MoM THA should be encouraged to return for clinical and radiographic followup, and clinicians should maintain a low threshold to perform a systematic evaluation. Early diagnosis and appropriate treatment are recommended to prevent the damaging effects of advanced ARMD. Level IV, Therapeutic study.
Meuret, Pascal; Bouvet, Lionel; Villet, Benoit; Hafez, Mohamed; Allaouchiche, Bernard; Boselli, Emmanuel
2018-04-01
Intraoperative hypotension during hip fracture surgery is frequent in the elderly. No study has compared the haemodynamic effect of hypobaric unilateral spinal anaesthesia (HUSA) and standardised general anaesthesia (GA) in elderly patients undergoing hip fracture surgical repair. We performed a prospective, randomised open study, including 40 patients aged over 75 years, comparing the haemodynamic effects of HUSA (5 mg isobaric bupivacaine with 5 μg sufentanil and 1 mL sterile water) and GA (induction with etomidate/remifentanil and maintenance with desflurane/remifentanil). An incidence of severe hypotension, defined by a decrease in systolic blood pressure of >40% from baseline, was the primary endpoint. The incidence of severe hypotension was lower in the HUSA group compared with that in the GA group (32% vs. 71%, respectively, p=0.03). The median [IQR] ephedrine consumption was lower (p=0.001) in the HUSA group (6 mg, 0-17 mg) compared with that in the GA group (36 mg, 21-57 mg). Intraoperative muscle relaxation and patients' and surgeons' satisfaction were similar between groups. No difference was observed in 5-day complications or 30-day mortality. This study shows that HUSA provides better haemodynamic stability than GA, with lower consumption of ephedrine and similar operating conditions. This new approach of spinal anaesthesia seems to be safe and effective in elderly patients undergoing hip fracture surgery.
Fabricant, Peter D; Dy, Christopher J; Patel, Ronak M; Blanco, John S; Doyle, Shevaun M
2013-06-01
The recent emphasis on shared decision-making has increased the role of the Internet as a readily accessible medical reference source for patients and families. However, the lack of professional review creates concern over the quality, accuracy, and readability of medical information available to patients on the Internet. Three Internet search engines (Google, Yahoo, and Bing) were evaluated prospectively using 3 difference search terms of varying sophistication ("congenital hip dislocation," "developmental dysplasia of the hip," and "hip dysplasia in children"). Sixty-three unique Web sites were evaluated by each of 3 surgeons (2 fellowship-trained pediatric orthopaedic attendings and 1 orthopaedic chief resident) for quality and accuracy using a set of scoring criteria based on the AAOS/POSNA patient education Web site. The readability (literacy grade level) of each Web site was assessed using the Fleisch-Kincaid score. There were significant differences noted in quality, accuracy, and readability of information depending on the search term used. The search term "developmental dysplasia of the hip" provided higher quality and accuracy compared with the search term "congenital hip dislocation." Of the 63 total Web sites, 1 (1.6%) was below the sixth grade reading level recommended by the NIH for health education materials and 8 (12.7%) Web sites were below the average American reading level (eighth grade). The quality and accuracy of information available on the Internet regarding developmental hip dysplasia significantly varied with the search term used. Patients seeking information about DDH on the Internet may not understand the materials found because nearly all of the Web sites are written at a level above that recommended for publically distributed health information. Physicians should advise their patients to search for information using the term "developmental dysplasia of the hip" or, better yet, should refer patients to Web sites that they have personally reviewed for content and clarity. Orthopaedic surgeons, professional societies, and search engines should undertake efforts to ensure that patients have access to information about DDH that is both accurate and easily understandable.
HEMIARTHROPLASTY IN THE TREATMENT FRACTURES OF THE FEMORAL NECK
Ono, Nelson Keiske; de Andrade Lima, Guilherme Didier; Honda, Emerson Kiyoshi; Polesello, Giancarlo Cavalli; Guimarães, Rodrigo Pereira; Júnior, Walter Ricioli; de Queiroz, Marcelo Cavalheiro
2015-01-01
Objective: To epidemiologically and clinically evaluate patients with displaced femoral neck fractures that were surgically treatment with cemented hip hemiarthroplasty. Methods: All patients with displaced femoral neck fractures (Garden III and IV) who underwent cemented hip hemiarthroplasty using a unipolar prosthesis (Thompson), by means of a posterolateral access between June 2005 and September 2008 were retrospectively evaluated. Results: Seventy patients were initially evaluated. Their mean age was 83.1 years. The patients were predominantly female (84.3%). Thirty-six patients were monitored as outpatients for periods ranging from 10 to 48 months (mean of 26.5 months). Fifteen patients were lost to follow-up. Nineteen patients died, and the mortality rate within the first year was 25.4%. Patients classified as ASA III had a mortality rate of 25.7% and ASA II patients, a rate of 12.1%. Two patients had symptomatic deep vein thrombosis; one patient had an operative wound infection; and none of the patients presented hip dislocation. Most of the patients did not experience pain. Twelve patients (33%) showed deterioration of their walking ability. Conclusion: There were no cases of hip dislocation. Patients classified as ASA III had a higher mortality rate than did patients with ASA I or II. There was a worsening of walking ability in 33% of the patients. No revision due to loosening or pain was needed for any patient. Thirty patients did not present any pain (83.3%), four presented moderate pain (11.1%) and two presented intense pain (5.5%). PMID:27022567
Jung, N H; Heinen, F; Westhoff, B; Doederlein, L; Reissig, A; Berweck, S; Linder-Lucht, M; Schandelmaier, S; Mall, V
2011-02-01
We investigated the effect of BoNT/A injection on hip lateralisation in children with bilateral spastic cerebral palsy and bilateral adductor spasticity. Pelvic radiographs using Reimers' migration index (MI) were evaluated from 27 children (n=9 females, n=18 males; mean age 5.2 ± 1.96 years; range: 2-10 years; initial MI <50%) with bilateral spastic cerebral palsy over a time period of 2 years. All received injections of BoNT/A (Dysport) every 12 weeks with a dose of 30 Units per kilogram body weight into adductor and medial hamstring muscles on both sides. The MI was calculated before treatment and after 1 and 2 years. The mean MI increased from 25.5% (range: 0-48) to 26.7% (+1.2%, range: 0-79) on the right side and from 28.0% (range: 0-40) to 30.6% (+2.6%, range: 3-84) on the left side over 2 years, respectively. Hips of one patient dislocated bilaterally. The mean MI remained stable over 2 years. Although a specific BoNT/A effect cannot be proven because of the open design of this study, we provide strong evidence that the MI can be kept stable for a time period of 2 years under non-surgical management including therapy with BoNT/A even in CP patients with a high risk for hip dislocation. © Georg Thieme Verlag KG Stuttgart · New York.
Lewis, Cara L; Loverro, Kari L; Khuu, Anne
2018-04-01
Study Design Controlled laboratory study, case-control design. Background Despite recognition that femoroacetabular impingement syndrome (FAIS) is a movement-related disorder, few studies have examined dynamic unilateral tasks in individuals with FAIS. Objectives To determine whether movements of the pelvis and lower extremities in individuals with FAIS differ from those in individuals without hip pain during a single-leg step-down, and to analyze kinematic differences between male and female participants within groups. Methods Individuals with FAIS and individuals without hip pain performed a single-leg step-down while kinematic data were collected. Kinematics were evaluated at 60° of knee flexion. A linear regression analysis assessed the main effects of group, sex, and side, and the interaction of sex by group. Results Twenty individuals with FAIS and 40 individuals without hip pain participated. Individuals with FAIS performed the step-down with greater hip flexion (4.9°; 95% confidence interval [CI]: 0.5°, 9.2°) and anterior pelvic tilt (4.1°; 95% CI: 0.9°, 7.3°) than individuals without hip pain. Across groups, female participants performed the task with more hip flexion (6.1°; 95% CI: 1.7°, 10.4°), hip adduction (4.8°; 95% CI: 2.2°, 7.4°), anterior pelvic tilt (5.8°; 95% CI: 2.6°, 9.0°), pelvic drop (1.4°; 95% CI: 0.3°, 2.5°), and thigh adduction (2.7°; 95% CI: 1.3°, 4.2°) than male participants. Conclusion The results of this study suggest that individuals with FAIS have alterations in pelvic motion during a dynamic unilateral task. The noted altered movement patterns in the FAIS group may contribute to the development of hip pain and may be due to impairments that are modifiable through rehabilitation. J Orthop Sports Phys Ther 2018;48(4):270-279. Epub 6 Mar 2018. doi:10.2519/jospt.2018.7794.
Uncovertebral joint injury in cervical facet dislocation: the headphones sign.
Palmieri, Francesco; Cassar-Pullicino, Victor N; Dell'Atti, Claudia; Lalam, Radhesh K; Tins, Bernhard J; Tyrrell, Prudencia N M; McCall, Iain W
2006-06-01
The purpose of our study is to demonstrate the uncovertebral mal-alignment as a reliable indirect sign of cervical facet joint dislocation. We examined the uncovertebral axial plane alignment of 12 patients with unilateral and bilateral cervical facet joint dislocation (UCFJD and BCFJD, respectively), comparing its frequency to the reverse hamburger bun sign on CT and MR axial images. Of the seven cases with BCFJD, five clearly demonstrated the diagnostic reverse facet joint hamburger bun sign on CT and MR images, but in two cases this sign was not detectable. In the five cases with UCFJD, four demonstrated the reverse hamburger bun sign on both CT and MRI. In one case the reverse hamburger bun sign was not seen adequately with either image modality, but the facet dislocation was identified on sagittal imaging. The uncovertebral mal-alignment was detected in all 12 cases. Normally, the two components of the uncovertebral joint enjoy a concentric relationship that in the axial plane is reminiscent of the relationship of headphones with the wearer's head. We name this appearance the 'headphones' sign. Radiologists should be aware of the headphones sign as a reliable indicator of facet joint dislocation on axial imaging used in the assessment of cervical spine injuries.
Cai, Zhencun; Li, Lianyong; Zhang, Lijun; Ji, Shijun; Zhao, Qun
2017-02-01
Objective To evaluate the effect of dynamic long leg casting in paediatric patients with developmental dysplasia of hip (DDH) diagnosed at 12-18 months. Methods The adductor tenotomy, closed reduction, and dynamic long leg casting method was adopted to treat paediatric patients with DDH. The hips were divided into four groups according to the Tonnis radiographic dislocation classification. Groups were also classified according to the baseline acetabular index (AI): 30°-35°, 36°-40°, and > 40°. The outcomes of the reductions were evaluated according to McKay's hip function criteria and Severin's radiological criteria. Results A total of 246 patients (339 hips) had complete follow-up data. After 3 months of orthosis fixation, the results were satisfactory in 264 hips (77.88%). Hip function was rated as 'excellent' or 'good' in 43 of 51 (84.31%) Tonnis type 1 hips, 125 of 155 (80.65%) type 2 hips, 70 of 90 (77.78%) type 3 hips, and 34 of 43 (79.07%) type 4 hips. The higher the baseline AI, the lower the rates of 'excellent' and 'good' hip function. Favourable radiological results (Severin types I and II) were found in 266 of 339 (78.47) hips. Conclusions Dynamic long leg casting is an effective method for treating patients with DDH aged 12-18 months at diagnosis.
Prymka, M; Hassenpflug, J
2003-08-01
This paper presents the case of a 63 year old female with a severe coxarthrosis. She got a robot assited implantation of a cementless hip prosthesis (Osteolock, Stryker-Howmedica, Mühlheim). As operation robot the CASPAR-System (Orto-Maquet, Rastatt) was used. Initially, the clinical progress of the patient was fine. She was nearly painfree within 14 days and showed an acceptable range of motion in the operated joint (flexion/ extension 90 degrees /05 degrees /00 degrees ). She was mobilized with crutches and 15 kg weight bearing at the operated leg. 3 weeks postoperative the patient complaint about increasing pain without trauma or intensification of the weight bearing. X-rays showed not only a dislocated fracture of the lesser trochanter, but also a sinking combined with a malrotation of the stem. A revision operation was necessary,where we implanted a cemented stem. Now clinical progress was completely satisfying.
An unusual mode of failure of a tripolar constrained acetabular liner: a case report.
Banks, Louisa N; McElwain, John P
2010-04-01
Dislocation after primary total hip arthroplasty (THA) is the most commonly encountered complication and is unpleasant for both the patient and the surgeon. Constrained acetabular components can be used to treat or prevent instability after primary total hip arthroplasty. We present the case of a 42-year-old female with a BMI of 41. At 18 months post-primary THA the patient underwent further revision hip surgery after numerous (more than 20) dislocations. She had a tripolar Trident acetabular cup (Stryker-Howmedica-Osteonics, Rutherford, New Jersey) inserted. Shortly afterwards the unusual mode of failure of the constrained acetabular liner was noted from radiographs in that the inner liner had dissociated from the outer. The reinforcing ring remained intact and in place. We believe that the patient's weight, combined with poor abductor musculature caused excessive demand on the device leading to failure at this interface when the patient flexed forward. Constrained acetabular components are useful implants to treat instability but have been shown to have up to 42% long-term failure rates with problems such as dissociated inserts, dissociated constraining rings and dissociated femoral rings being sited. Sometimes they may be the only option left in difficult cases such as illustrated here, but still unfortunately have the capacity to fail in unusual ways.
Pérez-de la Cruz, S
One of the consequences of poor postural control in children with cerebral palsy is hip dislocation. This is due to the lack of weight-bearing in the sitting and standing positions. Orthotic aids can be used to prevent onset and/or progression. The aim of this study is to analyse the effectiveness of positioning systems in achieving postural control in patients with cerebral palsy, and discuss these findings with an emphasis on what may be of interest in the field of neurology. We selected a total of 18 articles on interventions in cerebral palsy addressing posture and maintenance of ideal postures to prevent deformities and related problems. The main therapeutic approaches employed combinations of botulinum toxin and orthoses, which reduced the incidence of hip dislocation although these results were not significant. On the other hand, using positioning systems in 3 different positions decreases use of botulinum toxin and surgery in children under 5 years old. The drawback is that these systems are very uncomfortable. Postural control systems helps control hip deformities in children with cerebral palsy. However, these systems must be used for prolonged periods of time before their effects can be observed. Copyright © 2015 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.
The three-pin modified 'Harrington' procedure for advanced metastatic destruction of the acetabulum.
Tillman, R M; Myers, G J C; Abudu, A T; Carter, S R; Grimer, R J
2008-01-01
Pathological fractures due to metastasis with destruction of the acetabulum and central dislocation of the hip present a difficult surgical challenge. We describe a series using a single technique in which a stable and long-lasting reconstruction was obtained using standard primary hip replacement implants augmented by strong, fully-threaded steel rods with cement and steel mesh, where required. Between 1997 and 2006, 19 patients with a mean age of 66 years (48 to 83) were treated using a modified Harrington technique. Acetabular destruction was graded as Harrington class II in six cases and class III in 13. Reconstruction was achieved using three 6.5 mm rods inserted through a separate incision in the iliac crest followed by augmentation with cement and a conventional cemented Charnley or Exeter primary hip replacement. There were no peri-operative deaths. At the final follow-up (mean 25 months (5 to 110)) one rod had fractured and one construct required revision. Of the 18 patients who did not require revision, 13 had died. The mean time to death was 16 months (5 to 55). The mean follow-up of the five survivors was 31 months (18 to 47). There were no cases of dislocation, deep infection or injury to a nerve, the blood vessels or the bladder.
Digital templating for THA: a simple computer-assisted application for complex hip arthritis cases.
Hafez, Mahmoud A; Ragheb, Gad; Hamed, Adel; Ali, Amr; Karim, Said
2016-10-01
Total hip arthroplasty (THA) is the standard procedure for end-stage arthritis of the hip. Its technical success relies on preoperative planning of the surgical procedure and virtual setup of the operative performance. Digital hip templating is one methodology of preoperative planning for THA which requires a digital preoperative radiograph and a computer with special software. This is a prospective study involving 23 patients (25 hips) who were candidates for complex THA surgery (unilateral or bilateral). Digital templating is done by radiographic assessment using radiographic magnification correction, leg length discrepancy and correction measurements, acetabular component and femoral component templating as well as neck resection measurement. The overall accuracy for templating the stem implant's exact size is 81%. This percentage increased to 94% when considering sizing within 1 size. Digital templating has proven effective, reliable and essential technique for preoperative planning and accurate prediction of THA sizing and alignment.
Olds, Margie; McNair, Peter; Nordez, Antoine; Cornu, Christophe
2011-01-01
Active muscle stiffness might protect the unstable shoulder from recurrent dislocation. To compare strength and active stiffness in participants with unilateral anterior shoulder instability and to examine the relationship between active stiffness and functional ability. Cross-sectional study. University research laboratory. Participants included 16 males (age range, 16-40 years; height = 179.4 ± 6.1 cm; mass = 79.1 ± 6.8 kg) with 2 or more episodes of unilateral traumatic anterior shoulder instability. Active stiffness and maximal voluntary strength were measured bilaterally in participants. In addition, quality of life, function, and perceived instability were measured using the Western Ontario Stability Index, American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form, and Single Alpha Numeric Evaluation, respectively. We found less horizontal adduction strength (t(15) = -4.092, P = .001) and less stiffness at 30% (t(14) = -3.796, P = .002) and 50% (t(12) = -2.341, P = .04) maximal voluntary strength in the unstable than stable shoulder. Active stiffness was not correlated with quality of life, function, or perceived instability (r range, 0.0-0.25; P > .05). The observed reduction in stiffness in the unstable shoulder warrants inclusion of exercises in the rehabilitation program to protect the joint from perturbations that might lead to dislocation. The lack of association between active stiffness and quality of life, function, or perceived instability might indicate that stiffness plays a less direct role in shoulder stability.
Pandit, R
1996-08-01
Primary bipolar femoral head arthroplasties performed on 100 osteoarthritic hips were studied to a minimum of 5 years after surgery. All arthroplasties were performed on physically active patients. At a mean follow-up period of 5.5 years, The Hospital for Special Surgery hip scores were good to excellent in 96 hips. Transient startup soreness constituted the most frequent complaint, occurring in 34 hips. Three hips had more persistent pain localized to the acetabulum, necessitating revision to fixed sockets, which alleviated the symptoms. Four additional hips, in heavy, active men, developed polyethylene fatigue fracture and component disassembly. Acetabular migration of more than 5 mm developed in one hip. Motion, as determined radiologically, occurred primarily at the inner bearing. There were no dislocations or infections in the series. The Bateman bipolar prosthesis provides generally good results in osteoarthritic hips. The shorter operating time and the case of revision are special advantages of bipolar devices. Start-up soreness and stiffness is a shortcoming in approximately one third of cases. Component disassembly in heavy, active men is a problem and the bipolar arthroplasty should be avoided in these patients. Start-up soreness was a significant problem in particular.
Hip health at skeletal maturity: a population-based study of young adults with cerebral palsy.
Wawrzuta, Joanna; Willoughby, Kate L; Molesworth, Charlotte; Ang, Soon Ghee; Shore, Benjamin J; Thomason, Pam; Graham, H Kerr
2016-12-01
We studied 'hip health' in a population-based cohort of adolescents and young adults with cerebral palsy to investigate associations between hip morphology, pain, and gross motor function. Ninety-eight young adults (65 males, 33 females) from the birth cohort were identified as having developed hip displacement (migration percentage >30) and were reviewed at a mean age of 18 years 10 months (range 15-24y). Hip morphology was classified using the Melbourne Cerebral Palsy Hip Classification Scale (MCPHCS). Severity and frequency of pain were recorded using Likert scales. Gross motor function was classified by the Gross Motor Function Classification System (GMFCS). Hip pain was reported in 72% of participants. Associations were found between pain scores and both hip morphology and GMFCS. Median pain severity score for MCPHCS grades 1 to 4 was 2 (interquartile range [IQR] 1.0-3.0) compared to 7 (IQR 6.0-8.0) for grades 5 and 6 (severe subluxation or dislocation). Hip surveillance and access to surgery were associated with improved hip morphology and less pain. Poor hip morphology at skeletal maturity was associated with high levels of pain. Limited hip surveillance and access to surgery, rather than GMFCS, was associated with poor hip morphology. The majority of young adults who had access to hip surveillance, and preventive and reconstructive surgery, had satisfactory hip morphology at skeletal maturity and less pain. © 2016 Mac Keith Press.
Saragaglia, D; Belvisi, B; Rubens-Duval, B; Pailhé, R; Rouchy, R C; Mader, R
2015-06-01
Large-diameter metal-on-metal hip prostheses are no longer used, but their outcomes after more than 5 years are unknown. We conducted a retrospective study with a 6.8-year mean follow-up to assess clinical outcomes after Durom™ cup implantation, including the dislocation rate, comparatively to the reference metal-on-polyethylene bearing. We determined the rate of failure ascribable to Durom™ cup use. We also looked for a sharp drop in the implant survival curve during the follow-up period and for factors associated with adverse reactions to metal debris (ARMDs). We hypothesised that clinical outcomes after Durom™ cup implantation were similar to those seen with a metal-on-polyethylene bearing, except for a lower rate of dislocation. We included 177 consecutive THA procedures that were performed between 2005 and 2008 in 165 patients with a mean age of 57.6 ± 9.4 years (range, 31-76 years) and involved the implantation of a Durom™ cup, a femoral head greater than 36mm in diameter, and a PF(®) femoral stem (Zimmer, Etupes, France). The mini-posterior approach was used, with 2mm of acetabular overreaming in 82% of cases, a short femoral neck in 75% of cases, and a mean cup inclination of 34 ± 5° (range, 21-50°). Outcomes were assessed for 156 THA procedures in 146 patients after a mean follow-up of 6 years 8 months. The mean Postel-Merle d'Aubigné score improved from 9.7 ± 2.7 (range, 4-14) to 17.4 ± 1.7 (range, 15-18) and the mean Harris hip score from 45.2 ± 15.3 (range, 9-83) to 96.3 ± 7 (75-100). No episodes of dislocation were recorded. We identified 7 failures ascribable to the Durom™ cup including 6 due to ARMD and 1 to aseptic loosening. Implant survival after a mean of 80months was 95.5% (95% CI, 93.1-99.2), with no sharp drop in the survival curve. The Durom™ cup eliminates the risk of hip dislocation and produces similar functional outcomes to those seen with metal-on-polyethylene bearings after a mean follow-up of 80 months. Nevertheless, given the difficulty in predicting ARMD and hypersensitivity reactions, the Durom™ cup has been discarded and patients carrying it are monitored closely. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Čustović, Svemir; Šadić, Sahmir; Vujadinović, Aleksandar; Hrustić, Asmir; Jašarević, Mahir; Čustović, Amer; Krupić, Ferid
2018-08-01
Aim To assess the relationship between the clinical sign of limited hip abduction and developmental dysplasia of the hip (DDH). Methods A research was conducted on 450 newborns at the Neonatal Unit at the Clinic of Gynaecology and Obstetrics and the Orthopaedics and Traumatology Clinic of the University Clinical Centre, Tuzla, between 30th August 2011 and 30th April 2012. Clinical (degree of hip abduction) and ultrasound examination of all newborns' hips were performed using the Graf method on their first day of life. Results Clinical sign of limited hip abduction showed significant predictive value for DDH. There were 67 (14.7%) newborns with the clinical sign of limited hip abduction, of which 26 (5.7%) were on the left hip, 11 (2.4%) on the right hip and 30 (6.6%) on both hips. Limited hip abduction had a positive predictive value (PPV) of 40.3% and a negative predictive value (NPV) of 80.4% for DDH. Conclusion Limited hip abduction, especially unilateral, is a useful and important clinical sign of DDH. Doctors, who perform the first examination of the child after birth, would have to pay attention to this clinical sign. Newborns with this clinical sign would have to go to an ultrasound examination of the hips for further diagnosis. Copyright© by the Medical Assotiation of Zenica-Doboj Canton.
Yilmaz, Serdar; Aksahin, Ertugrul; Duran, Semra; Bicimoglu, Ali
2017-09-01
There has been little information about the long-term status of the iliopsoas, which is the main flexor of the hip, after iliopsoas tenotomy in the treatment of developmental dysplasia of the hip (DDH). The aim of this study was to assess the status of the iliopsoas muscle and other flexors and extensors of the hip in long-term follow-up with magnetic resonance imaging after complete iliopsoas tenotomy in patients with unilateral DDH treated with open reduction with a medial approach. The study included 20 patients who underwent open reduction with a medial approach for unilateral DDH and had long-term follow-up. Magnetic resonance imaging assessment of iliopsoas, rectus femoris, tensor fasia lata, sartorius, and gluteus maximus muscles was applied and the muscles of the hip that was operated on were compared with the unoperated hip. In addition, the iliopsoas muscle was examined for reattachment and the effect of reattachment was evaluated. The mean age at the time of operation was 10.53±3.61 months (range, 5 to 18 mo), and mean follow-up was 16.65±2.16 years (range, 13 to 20 y). Spontaneous reattachment of the iliopsoas was observed in 18 patients (90%), either in the lesser trochanter (65%) or the superior part of it (25%). There was no significant difference between the hips that were operated on and those that were not with regard to the mean cross-sectional areas (CSA) of the tensor fascia lata, rectus femoris, sartorius, and gluteus maximus muscles. The CSA of the tensor fascia lata, rectus femoris, sartorius, and gluteus maximus muscles showed no significant difference (P>0.05); however, CSA of iliopsoas muscle was significantly reduced in the operated hip (P<0.001). Although the iliopsoas tendon was atrophied after complete iliopsoas tenotomy, it was reattached in 90% of the patients spontaneously in long-term follow-up. There was no statistically significant compensatory hypertrophy in any muscles in response to iliopsoas atrophy. Level IV-Therapeutic.
Kulkarni, J; Adams, J; Thomas, E; Silman, A
1998-08-01
To investigate the association between amputation, osteoarthritis and osteopenia in male war veterans with major lower limb amputations. Specific questions were to determine whether lower limb amputees following trauma are at subsequent risk of developing osteoarthritis (OA) and osteoporosis of the hip on both the amputated and nonamputated sides. Retrospective cohort study in British Male Second World War veterans with major unilateral lower limb amputations. Seventy-five male Second World War veterans with major lower limb amputations known to be alive were invited to participate from a subregional rehabilitation centre. After exclusions, 44 agreed to attend for examination and radiological screening. The presence of hip OA was determined from a single anterior posterior pelvic X-ray using two approaches: minimum joint space and the Kellgren and Lawrence (K&L) scoring system. Bone mineral density (BMD) was measured by a dual energy X-ray absorptiometry (DXA) scan and prosthetic rehabilitation outcome measures were recorded. Twenty-seven (61%) hips on the amputated side and 10 (23%) on the nonamputated side were positive for OA (based on Kellgren and Lawrence grade of >2). Using a minimum joint space threshold of below 2.5 mm, 24 (55%) hips on the amputation side and 8 (18%) on the nonamputated side were also positive for OA. There was a threefold increased risk of OA for those with above-knee compared to a below-knee amputation. By contrast, from published general population surveys only 4 (11%) cases of hip OA would have been expected on both the amputated and nonamputated hips. There was a significant decrease in femoral neck BMD in the amputated side (p <0.0001) and significantly lower BMD in above-knee amputees than in below-knee amputees (p = 0.0027) as compared to normal age- and sex-matched population. Male war veterans with unilateral major lower limb amputations develop significantly more osteoarthritis of the hip than expected on both ipsi- and contralateral sides. Amputation was also associated with loss of bone density. Above-knee amputees develop significantly more hip osteoarthritis and osteopenia of greater severity in the amputated side than below-knee amputees.
Osteonecrosis of the hip in patients with aplastic anemia.
Park, Jeongmi; Jun, Jeongsu; Kim, Yongsik; Lee, Jongwook; Kim, Chunchu; Hahn, Seongtae
2002-01-01
The incidence and clinical and magnetic resonance imaging features of osteonecrosis of the hip were evaluated in patients with aplastic anemia. Two hundred and forty-one patients with aplastic anemia were examined using MR imaging of bone marrow during the five years from 1994 to 1998. Osteonecrosis of the hip was observed on MR imaging in nineteen (15 males and 4 females, mean age 35 yr) of the 241 patients. It was present in both hips in 14 patients, and there were five cases with unilateral occurrence, with a total of 33 involved hips. All except for five hips with associated bone marrow edema revealed increased fatty marrow conversion in the proximal femoral metaphysis. In nine patients, osteonecrosis was detected without any pain. Five patients already had osteonecrosis before any medication was administered. Twelve patients received antilymphocyte globulin, and seven patients received a low dose of steroids before the MR diagnosis of osteonecrosis. Osteonecrosis of the hip frequently develops in patients with aplastic anemia (7.9%), associated with fatty marrow conversion of the proximal femoral metaphysis. PMID:12483006
Abolghasemian, Mansour; Samiezadeh, Saeid; Jafari, Davood; Bougherara, Habiba; Gross, Allan E; Ghazavi, Mohammad T
2013-06-01
To study the direction and biomechanical consequences of hip center of rotation (HCOR) migration in Crowe type III and VI hips after total hip arthroplasty, post-operative radiographs and CT scans of several unilaterally affected hips were evaluated. Using a three-dimensional model of the human hip, the HCOR was moved in all directions, and joint reaction force (JRF) and abductor muscle force (AMF) were calculated for single-leg stance configuration. Comparing to the normal side, HCOR had displaced medially and inferiorly by an average of 23.4% and 20.8%, respectively, of the normal femoral head diameter. Significant decreases in JRF (13%) and AMF (46.13%) were observed in a presumptive case with that amount of displacement. Isolated inferior displacement had a small, increasing effect on these forces. In Crowe type III and IV hips, the HCOR migrates inferiorly and medially after THA, resulting in a decrease in JRF, AMF, and abductor muscle contraction force. Copyright © 2013 Elsevier Inc. All rights reserved.
Kim, J H; Nam, D H
2015-10-01
Most surgeons agree that closed treatment provides the best results for condylar fractures in children. Nevertheless, treatment of the paediatric mandibular condyle fracture that is severely displaced or dislocated is controversial. The purpose of this study was to investigate the long-term clinical and radiological outcomes following the treatment of displaced or dislocated condylar fractures in children using threaded Kirschner wire and external rubber traction. This procedure can strengthen the advantage of closed reduction and make up for the shortcomings of open reduction. From March 1, 2005 to December 25, 2011, 11 children aged between 4 and 12 years with displaced or dislocated mandibular condyle fractures were treated using threaded Kirschner wire and external rubber traction under portable C-arm fluoroscopy. All patients had unilateral displaced or dislocated condylar fractures. The follow-up period ranged from 24 to 42 months (mean 29.3 months). Normal occlusion and pain-free function of the temporomandibular joint, without deviation or limitation of jaw opening, was achieved in all patients. This closed reduction technique in displaced or dislocated condylar fractures in children offers a reliable solution in preventing the unfavourable sequelae of closed treatment and the open technique, such as altered morphology, functional disturbances, and facial nerve damage. Copyright © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Meuret, Pascal; Bouvet, Lionel; Villet, Benoit; Hafez, Mohamed; Allaouchiche, Bernard
2018-01-01
Objective Intraoperative hypotension during hip fracture surgery is frequent in the elderly. No study has compared the haemodynamic effect of hypobaric unilateral spinal anaesthesia (HUSA) and standardised general anaesthesia (GA) in elderly patients undergoing hip fracture surgical repair. Methods We performed a prospective, randomised open study, including 40 patients aged over 75 years, comparing the haemodynamic effects of HUSA (5 mg isobaric bupivacaine with 5 μg sufentanil and 1 mL sterile water) and GA (induction with etomidate/remifentanil and maintenance with desflurane/remifentanil). An incidence of severe hypotension, defined by a decrease in systolic blood pressure of >40% from baseline, was the primary endpoint. Results The incidence of severe hypotension was lower in the HUSA group compared with that in the GA group (32% vs. 71%, respectively, p=0.03). The median [IQR] ephedrine consumption was lower (p=0.001) in the HUSA group (6 mg, 0–17 mg) compared with that in the GA group (36 mg, 21–57 mg). Intraoperative muscle relaxation and patients’ and surgeons’ satisfaction were similar between groups. No difference was observed in 5-day complications or 30-day mortality. Conclusion This study shows that HUSA provides better haemodynamic stability than GA, with lower consumption of ephedrine and similar operating conditions. This new approach of spinal anaesthesia seems to be safe and effective in elderly patients undergoing hip fracture surgery. PMID:29744247
Clinical study on the unloading effect of hip bracing on gait in patients with hip osteoarthritis.
Nérot, Agathe; Nicholls, Micah
2017-04-01
Internal hip abduction moment is a major indicator for hip loading. A new hip bracing concept was designed to unload the cartilaginous area in hip osteoarthritis via an abduction and external rotation force intended to alter the weight bearing area and reduce compression through the joint. To assess the effect of a novel brace on hip rotation in the transverse and coronal planes and on the hip abduction moment. Repeated measures. Gait analysis was performed on 14 subjects with unilateral symptomatic hip osteoarthritis. Pain, joint motion, moments and vertical ground reaction force were compared between the braced and the unbraced (control), randomly assigned, conditions. Nine participants felt an immediate reduction in pain while walking with the hip brace. Peak hip abduction moment significantly decreased on the osteoarthritis side ( p = 0.017). Peak hip adduction ( p = 0.004) and internal rotation ( p = 0.0007) angles significantly decreased at stance with the brace. Wearing the brace would appear to reduce the compressive joint reaction force at the femuroacetabular interface as indicated by a reduction in internal hip abduction moment along with immediate pain reduction in nine participants. Further long-term studies are warranted. Clinical relevance The brace rotates the hip in the transverse and coronal planes, possibly resulting in a decrease in load through the diseased area of cartilage. In some patients, an immediate decrease in pain was experienced. The brace offers an alternative solution for hip osteoarthritis patients not ready for a hip replacement.
Viste, A; Chouteau, J; Testa, R; Chèze, L; Fessy, M-H; Moyen, B
2011-05-01
Accurate positioning of the acetabular cup in primary total hip arthroplasty is critical to decrease the rate of dislocation. Inaccurate orientation of the cup is the most common error during this procedure. Target acetabular orientation is still controversial. An original study found a dislocation rate of 0.6% when the cup was aligned with the transverse acetabular ligament (TAL). TAL is a patient-specific anatomical landmark and a tool for cup orientation. Eight cadaveric pelves (14 hips included for study) were harvested in toto at our research laboratory. Anatomical versions of the TAL, labrum and horns were measured in relation to the anterior pelvic plane. A navigator sensor and an optoelectronic device (Motion Analysis™) were used. Anatomical versions of the TAL, horns and labrum averaged 1.9° (range, -8° to +13.3°), 3° (range, -12.2° to 14°), and 26.3° (range, 17.4° to 41.8°), respectively. To our knowledge, this is the first study to report the orientation of the periacetabular soft-tissues. TAL anteversion was outside the safe zone described by Lewinnek, while labrum anteversion was within this safe-zone. We discuss the reference used, Lewinnek's safe zone, and functional orientation of the implants. Lewinnek's safe-zone does not seem to be valid. The TAL seems to be a specific reference for each patient but its reliability must still be confirmed as an adequate reference for positioning the cup in total hip arthroplasty. Copyright © 2011 Elsevier Masson SAS. All rights reserved.
Modern dual-mobility cup implanted with an uncemented stem: about 100 cases with 12-year follow-up.
Philippot, Remi; Meucci, Jean Francois; Boyer, Bertrand; Farizon, Frederic
2013-09-01
We report the results of a 12-year follow-up retrospective series of 100 total hip arthroplasties using cementless, press-fit, dual-mobility acetabular cups. The aim of our study was to evaluate the clinical and radiographic results of this acetabular cup at last follow-up. This continuous and homogeneous series included 100 primary total hip arthroplasties performed during the year 2000. The THA combined a Corail® stem (Corail®, Depuy, Warsaw, IN) with a stainless steel Novae Sunfit® (Serf, Decines, France) acetabular cup. Fifteen patients died and 2 were lost to follow-up. Two cases of early dislocation were observed, and 3 cases of aseptic loosening of the acetabular component were reported. The mean stem subsidence was 0.71 mm, the mean craniopodal acetabular migration was 1.37 mm, and the mean medio-lateral acetabular migration was 1.52 mm. The 12-year survivorship is comparable to the data from the literature. The low dislocation rate at 12 years confirms the long-term, high stability of dual mobility, which should be recommended in primary THA for patients at risk for postoperative instability. The absence of true intraprosthetic dislocation events at 12-year follow-up provides evidence of the good quality of the latest generation of polyethylene liners and the necessity of combining thin-mirror, polished femoral necks with dual-mobility cups.
Acetabular-epiphyseal angle and hip dislocation in cerebral palsy: a preliminary study.
Alí-Morell, O J; Zurita-Ortega, F; Davó-Jiménez, I; Segura-Biedma, S
To relate, in non-ambulatory subjects with palsy, Reimers' migration percentage with standardized radiological measurements, including the acetabular-epiphyseal angle. Descriptive, observational and transversal study of 15 individuals with cerebral palsy at levels IV and V of the Gross Motor Function Classification System, aged between 3 and 9 years. Radiological measurements of the acetabular index, Hilgenreiner's epiphyseal angle, acetabular-epiphyseal angle, neck-shaft angle and Reimers' migration percentage of each of the hips were performed. Correlations between acetabular index, epiphyseal angle and acetabular-epiphyseal angle were obtained with respect to the Reimers migration percentage. For hips with a migration rate of 15% or less, a positive correlation was observed between acetabular and epiphyseal angles. In our population, the measurement between acetabular and epiphyseal inclination represents the highest association with the hip migration percentage. Copyright © 2018 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.
Svehlík, Martin; Kraus, Tanja; Steinwender, Gerhard; Zwick, Ernst B; Linhart, Wolfgang E
2012-06-01
Legg-Calvé-Perthes disease (LCP) severely limits the range of hip motion and hinders a normal gait. Loading of the hip joint is a major consideration in LCP treatment. The aim of this study was to evaluate gait patterns in LCP and identify gait modifications to decrease the load on the affected hip. Forty children with unilateral LCP were divided into three groups based on the time base integral of the hip abductor moments during single stance on the affected side acquired during instrumented 3D gait analysis. X-rays of the affected hip were classified according to Herring and Catterall. Children in the "unloading" group spontaneously adopted a Duchenne-like gait with pelvis elevation, hip abduction and external rotation during single support phase. The "normal-loading" group showed pelvis elevation with a neutral hip position in the frontal plane. In the "overloading" group the pelvis dropped to the swinging limb at the beginning of stance accompanied by prolonged hip adduction. The time base integral of the hip abductor moments during single stance correlated positively with the X-ray classifications of Herring and Catterall, hip abduction angle and age. Older children preferred to walk in hip adduction during single stance, had more impaired hips and tended to overload them. The hip overloading pattern should be avoided in children with LCP. Gait training to unload the hip might become an integral component of conservative treatment in children with LCP.
Sochacki, Kyle R; Jack, Robert A; Safran, Marc R; Nho, Shane J; Harris, Joshua D
2018-06-01
The purpose of this study was to compare (1) major complication, (2) revision, and (3) conversion to arthroplasty rates following hip arthroscopy between database studies and original research peer-reviewed publications. A systematic review was performed using PRISMA guidelines. PubMed, SCOPUS, SportDiscus, and Cochrane Central Register of Controlled Trials were searched for studies that investigated major complication (dislocation, femoral neck fracture, avascular necrosis, fluid extravasation, septic arthritis, death), revision, and hip arthroplasty conversion rates following hip arthroscopy. Major complication, revision, and conversion to hip arthroplasty rates were compared between original research (single- or multicenter therapeutic studies) and database (insurance database using ICD-9/10 and/or current procedural terminology coding terminology) publishing studies. Two hundred seven studies (201 original research publications [15,780 subjects; 54% female] and 6 database studies [20,825 subjects; 60% female]) were analyzed (mean age, 38.2 ± 11.6 years old; mean follow-up, 2.7 ± 2.9 years). The database studies had a significantly higher age (40.6 + 2.8 vs 35.4 ± 11.6), body mass index (27.4 ± 5.6 vs 24.9 ± 3.1), percentage of females (60.1% vs 53.8%), and longer follow-up (3.1 ± 1.6 vs 2.7 ± 3.0) compared with original research (P < .0001 for all). Ninety-seven (0.6%) major complications occurred in the individual studies, and 95 (0.8%) major complications occurred in the database studies (P = .029; relative risk [RR], 1.3). There was a significantly higher rate of femoral neck fracture (0.24% vs 0.03%; P < .0001; RR, 8.0), and hip dislocation (0.17% vs 0.06%; P = .023; RR, 2.2) in the database studies. Reoperations occurred at a significantly higher rate in the database studies (11.1% vs 7.3%; P < .001; RR, 1.5). There was a significantly higher rate of conversion to arthroplasty in the database studies (8.0% vs 3.7%; P < .001; RR, 2.2). Database studies report significantly increased major complication, revision, and conversion to hip arthroplasty rates compared with original research investigations of hip arthroscopy outcomes. Level IV, systematic review of Level I-IV studies. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Experiment K-314: Fetal and neonatal rat bone and joint development following in Utero spaceflight
NASA Technical Reports Server (NTRS)
Sabelman, E. E.; Holton, E. M.; Arnaud, C. D.
1981-01-01
Infant rat limb specimens from Soviet and U.S. ground-based studies were examined by radiography, macrophotography, histologic sectioning and staining and scanning electron microscopy. A comparison was conducted between vivarium and flight-type diets suggesting that nutritional obesity may adversely affect pregnancy. Data were obtained on maturation of ossification centers, orientation of collagen fibers in bone, tendon and ligaments, joint surface texture and spatial relationships of bones of the hind limb. Computer reconstructions of the knee and hip show promise as a means of investigating the etiology of congenital hip dislocation.
The effects of age and type of carrying task on lower extremity kinematics
Gillette, Jason C.; Stevermer, Catherine A.; Miller, Ross H.; Meardon, Stacey A.; Schwab, Charles V.
2009-01-01
The purpose of this study was to determine the effects of age, load amount, and load symmetry on lower extremity kinematics during carrying tasks. Forty-two participants in four age groups (8-10 years, 12-14 years, 15-17 years, and adults) carried loads of 0%, 10%, and 20% body weight (BW) in large or small buckets unilaterally and bilaterally. Reflective markers were tracked to determine total joint ROM and maximum joint angles during the stance phase of walking. Maximum hip extension, hip adduction, and hip internal rotation angles were significantly greater for each of the child/adolescent age groups as compared to adults. In addition, maximum hip internal rotation angles significantly increased when carrying a 20% BW load. The observation that the 8-10 year old age group carried the lightest absolute loads and still displayed the highest maximum hip internal rotation angles suggests a particular necessity in setting carrying guidelines for the youngest children. PMID:20191410
Transient osteoporosis of pregnancy of the bilateral hips in twin gestation: a case series.
Reese, Maria E; Fitzgerald, Colleen; Hynes, Christina
2015-01-01
Transient osteoporosis of pregnancy has been described as a rare, self-limiting disease of unclear etiology that presents as severe pain, which typically affects pregnant women in their third trimester. We describe 3 cases of primigravid pregnant women with twin gestation who reported unilateral hip pain and who were diagnosed with transient osteoporosis of pregnancy of the hip by magnetic resonance imaging. These women were advised to undergo limited weight bearing and activity modification to minimize the risk of fracture. Each patient was able to proceed through her pregnancy, delivery, and postpartum course without complication, with symptom resolution, and return to unrestricted activity. Copyright © 2015 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Gardner, R O E; Bradley, C S; Howard, A; Narayanan, U G; Wedge, J H; Kelley, S P
2014-02-01
The incidence of clinically significant avascular necrosis (AVN) following medial open reduction of the dislocated hip in children with developmental dysplasia of the hip (DDH) remains unknown. We performed a systematic review of the literature to identify all clinical studies reporting the results of medial open reduction surgery. A total of 14 papers reporting 734 hips met the inclusion criteria. The mean follow-up was 10.9 years (2 to 28). The rate of clinically significant AVN (types 2 to 4) was 20% (149/734). From these papers 221 hips in 174 children had sufficient information to permit more detailed analysis. The rate of AVN increased with the length of follow-up to 24% at skeletal maturity, with type 2 AVN predominating in hips after five years' follow-up. The presence of AVN resulted in a higher incidence of an unsatisfactory outcome at skeletal maturity (55% vs 20% in hips with no AVN; p < 0.001). A higher rate of AVN was identified when surgery was performed in children aged < 12 months, and when hips were immobilised in ≥ 60° of abduction post-operatively. Multivariate analysis showed that younger age at operation, need for further surgery and post-operative hip abduction of ≥ 60° increased the risk of the development of clinically significant AVN.
Haughom, Bryan D; Erickson, Brandon J; Hellman, Michael D; Jacobs, Joshua J
2015-08-01
Although metal-on-metal (MoM) bearing surfaces provide low rates of volumetric wear and increased stability, evidence suggests that certain MoM hip arthroplasties have high rates of complication and failure. Some evidence indicates that women have higher rates of failure compared with men; however, the orthopaedic literature as a whole has poorly reported such complications stratified by gender. This systematic review aimed to: (1) compare the rate of adverse local tissue reaction (ALTR); (2) dislocation; (3) aseptic loosening; and (4) revision between men and women undergoing primary MoM hip resurfacing arthroplasty (HRA). Systematic MEDLINE and EMBASE searches identified all level I to III articles published in peer-reviewed journals, reporting on the outcomes of interest, for MoM HRA. Articles were limited to those with 2-year followup that reported outcomes by gender. Ten articles met inclusion criteria. Study quality was evaluated using the Modified Coleman Methodology Score; the overall quality was poor. Heterogeneity and bias were analyzed using a Mantel-Haenszel statistical method. Women demonstrated an increased odds of developing ALTR (odds ratio [OR], 5.70 [2.71-11.98]; p<0.001), dislocation (OR, 3.04 [1.2-7.5], p=0.02), aseptic loosening (OR, 3.18 [2.21-4.58], p<0.001), and revision (OR, 2.50 [2.25-2.78], p<0.001) after primary MoM HRA. A systematic review of the currently available literature reveals a higher rate of complications (ALTR, dislocation, aseptic loosening, and revision) after MoM HRA in women compared with men. Although femoral head size has been frequently implicated as a prime factor in the higher rate of complication in women, further research is necessary to specifically probe this relationship. Retrospective studies of data available (eg, registry data) should be undertaken, and moving forward studies should report outcomes by gender (particularly complications). Level III, therapeutic study.
A Novel Approach for Dynamic Testing of Total Hip Dislocation under Physiological Conditions.
Herrmann, Sven; Kluess, Daniel; Kaehler, Michael; Grawe, Robert; Rachholz, Roman; Souffrant, Robert; Zierath, János; Bader, Rainer; Woernle, Christoph
2015-01-01
Constant high rates of dislocation-related complications of total hip replacements (THRs) show that contributing factors like implant position and design, soft tissue condition and dynamics of physiological motions have not yet been fully understood. As in vivo measurements of excessive motions are not possible due to ethical objections, a comprehensive approach is proposed which is capable of testing THR stability under dynamic, reproducible and physiological conditions. The approach is based on a hardware-in-the-loop (HiL) simulation where a robotic physical setup interacts with a computational musculoskeletal model based on inverse dynamics. A major objective of this work was the validation of the HiL test system against in vivo data derived from patients with instrumented THRs. Moreover, the impact of certain test conditions, such as joint lubrication, implant position, load level in terms of body mass and removal of muscle structures, was evaluated within several HiL simulations. The outcomes for a normal sitting down and standing up maneuver revealed good agreement in trend and magnitude compared with in vivo measured hip joint forces. For a deep maneuver with femoral adduction, lubrication was shown to cause less friction torques than under dry conditions. Similarly, it could be demonstrated that less cup anteversion and inclination lead to earlier impingement in flexion motion including pelvic tilt for selected combinations of cup and stem positions. Reducing body mass did not influence impingement-free range of motion and dislocation behavior; however, higher resisting torques were observed under higher loads. Muscle removal emulating a posterior surgical approach indicated alterations in THR loading and the instability process in contrast to a reference case with intact musculature. Based on the presented data, it can be concluded that the HiL test system is able to reproduce comparable joint dynamics as present in THR patients.
A Novel Approach for Dynamic Testing of Total Hip Dislocation under Physiological Conditions
Herrmann, Sven; Kluess, Daniel; Kaehler, Michael; Grawe, Robert; Rachholz, Roman; Souffrant, Robert; Zierath, János; Bader, Rainer; Woernle, Christoph
2015-01-01
Constant high rates of dislocation-related complications of total hip replacements (THRs) show that contributing factors like implant position and design, soft tissue condition and dynamics of physiological motions have not yet been fully understood. As in vivo measurements of excessive motions are not possible due to ethical objections, a comprehensive approach is proposed which is capable of testing THR stability under dynamic, reproducible and physiological conditions. The approach is based on a hardware-in-the-loop (HiL) simulation where a robotic physical setup interacts with a computational musculoskeletal model based on inverse dynamics. A major objective of this work was the validation of the HiL test system against in vivo data derived from patients with instrumented THRs. Moreover, the impact of certain test conditions, such as joint lubrication, implant position, load level in terms of body mass and removal of muscle structures, was evaluated within several HiL simulations. The outcomes for a normal sitting down and standing up maneuver revealed good agreement in trend and magnitude compared with in vivo measured hip joint forces. For a deep maneuver with femoral adduction, lubrication was shown to cause less friction torques than under dry conditions. Similarly, it could be demonstrated that less cup anteversion and inclination lead to earlier impingement in flexion motion including pelvic tilt for selected combinations of cup and stem positions. Reducing body mass did not influence impingement-free range of motion and dislocation behavior; however, higher resisting torques were observed under higher loads. Muscle removal emulating a posterior surgical approach indicated alterations in THR loading and the instability process in contrast to a reference case with intact musculature. Based on the presented data, it can be concluded that the HiL test system is able to reproduce comparable joint dynamics as present in THR patients. PMID:26717236
Yue, Dong; Fan Rong, Cheng; Ning, Cai; Liang, Hu; Ai Lian, Liu; Ru Xin, Wang; Ya Hong, Luo
2018-07-01
Background The evaluation of hip arthroplasty is a challenge in computed tomography (CT). The virtual monochromatic spectral (VMS) images with metal artifact reduction software (MARs) in spectral CT can reduce the artifacts and improve the image quality. Purpose To evaluate the effects of VMS images and MARs for metal artifact reduction in patients with unilateral hip arthroplasty. Material and Methods Thirty-five patients underwent dual-energy CT. Four sets of VMS images without MARs and four sets of VMS images with MARs were obtained. Artifact index (AI), CT number, and SD value were assessed at the periprosthetic region and the pelvic organs. The scores of two observers for different images and the inter-observer agreement were evaluated. Results The AIs in 120 and 140 keV images were significantly lower than those in 80 and 100 keV images. The AIs of the periprosthetic region in VMS images with MARs were significantly lower than those in VMS images without MARs, while the AIs of pelvic organs were not significantly different. VMS images with MARs improved the accuracy of CT numbers for the periprosthetic region. The inter-observer agreements were good for all the images. VMS images with MARs at 120 and 140 keV had higher subjective scores and could improve the image quality, leading to reliable diagnosis of prosthesis-related problems. Conclusion VMS images with MARs at 120 and 140 keV could significantly reduce the artifacts from hip arthroplasty and improve the image quality at the periprosthetic region but had no obvious advantage for pelvic organs.
Won, Yougun; Lee, Gi Soo; Kim, Sang Bum; Kim, Sun Joong; Yang, Kyu Hyun
2016-11-01
As anatomical reduction of the articular surface of femoral head fractures and restoration of damaged cartilage are essential for good long-term results, many treatment options have been suggested, including fixation of the fracture using various surgical exposures and implants, as well as arthroscopic irrigation and debridement, bone marrow stimulating techniques, osteochondral allograft, autograft, and autogenous chondrocyte implantation. We report a case of osteochondral autograft harvested from its own femoral articular surface through surgical hip dislocation. The osteochondral graft was harvested from the inferior non-weight-bearing articular surface and grafted to the osteochondral defect. One year later, the clinical and radiological results were good, without the collapse of the femoral head or arthritic change. This procedure introduced in our case is considered convenient and able to lessen surgical time without morbidity of the donor site associated with the harvest.
Complications Are Not Increased With Acetabular Revision of Metal-on-metal Total Hip Arthroplasty.
Penrose, Colin T; Seyler, Thorsten M; Wellman, Samuel S; Bolognesi, Michael P; Lachiewicz, Paul F
2016-10-01
Isolated revision of the acetabular component in the setting of total hip arthroplasty has an increased risk of dislocation. With local soft tissue destruction frequently associated with failed metal-on-metal (MoM) bearings, it is presumed that acetabular revision of these hips will have even greater risk of complications. However, no study directly compares the complications of MoM with metal-on-polyethylene (MoP) acetabular revisions. In the context of a large database analysis, we asked the following questions: (1) Are there differences in early medical or wound complications after isolated acetabular revision of MoM and MoP bearing surfaces? (2) Are there differences in the frequency of dislocation, deep infection, and rerevision based on the bearing surface of the original implant? A review of the 100% Medicare database from 2005 to 2012 was performed using International Classification of Diseases, 9th Revision and Current Procedural Terminology codes. We identified 451 patients with a MoM bearing and 628 patients with a MoP bearing who had an isolated acetabular revision and a minimum followup of 2 years. The incidence, odds ratios, and 95% confidence intervals for early medical or wound complications were calculated using a univariate analysis at 30 days with patient sex and age group-adjusted analysis for blood transfusion. The incidence, odds ratio, and 95% confidence intervals for dislocation, deep infection, and rerevision were calculated using a univariate analysis at 30 day, 90 days, 1 year, and 2 years using a subgroup analysis with the Cochran-Mantel-Haenszel test to adjust for patient gender and age groups. There were no differences between the MoM and MoP isolated acetabular revisions in the incidence of 30-day local complications. There was a greater risk of transfusion in the MoP group than the MoM group (134 of 451 [30%] versus 230 of 628 [37%]; odds ratio [OR], 0.731; 95% confidence interval [CI], 0.565-0.948; p = 0.018). There were no differences at 2 years between the MoM and MoP acetabular revisions in the incidence of dislocation, infection, or rerevision. When analyzed by patient sex and age group, there were more infections in the age 70 to 79 years MoP group compared with MoM (10 of 451 [5%] versus 29 of 628 [10%]; OR, 4.47; CI, 1.699-11.761; p = 0.001). There were high rates of dislocation, infection, and rerevision in both revision cohorts. The rate of dislocation was not greater after acetabular revision of MoM bearings at 2 years. Based on these findings, clinicians should counsel these patients preoperatively about the risks of these complications. Dual-mobility and constrained components have specific advantages and disadvantages in these settings and should be further studied. Level III, therapeutic study.
1988-09-01
Perineoplasty Vaginal cyst, cautery Vaginal web, excision Surgical Patients 95 ORTHOPEDIC Arthrodesis of phalanges Arthroscopy Bone biopsy Bunionectomy...Manipulation of shoulder, knee, or hip Mass excision with scar revision Meniscectomy (if done through arthroscopy ) Metatarsal head, excision unilateral
Prospective monitoring improves outcomes of primary total hip replacement: a cohort study
Streubel, Philipp N; Pachón, Marcela; Kerguelén, Carlos A; Navas, José; Portocarrero, Julio; Pesantez, Rodrigo F; Zayed, Gamal; Carrillo, Germán; Llinás, Adolfo M
2009-01-01
Background Over the past decade several studies have questioned current standards of patient safety in health care delivery. In response, our institution started a clinical pathway for total hip replacement in 1996. Prospective monitoring with regular feedback sessions to the individuals involved in patient care did however not start until 2003. The present study evaluates the effect of prospective monitoring on outcomes of total hip replacement. Methods Clinical records of patients undergoing primary elective total hip replacement between 1997 and 2004 were reviewed. Data on adverse events as well as adherence to protocols for venous thromboembolism prophylaxis were extracted retrospectively for the period 1997 to 2001 and prospectively from 2003 to 2004. Results were compared and analyzed in order to establish possible improvement in outcomes. Data was analyzed with Chi-square or Fisher's Exact test for categorical variables and Student's t-test for continuous variables. Alpha was set as less than 5% and analysis was performed with Stata 9.0 for Macintosh. Results Two-hundred and eighty-three patients were included from 1997 to 2001, and 62 from 2003 to 2004. Mean age, male to female ratio and initial diagnosis were similar in both groups. At least one adverse event occurred in 45% of patients in 1997–2001 and in 21% in 2003–2004 (p < 0.001). In-hospital hip dislocations occurred in 6% and 0% (p = 0.05), oliguria in 19% and 5% (p = 0.007), SSI and VTE in 3% and 0% (p = 0.37), adverse drug reactions in 11% and 13% (p = 0.66) and non-adherence to VTE prophylaxis protocols in 15% and 2% of cases respectively (p = 0.002). Conclusion Overall rate of adverse events as well as in-hospital hip dislocations, oliguria and non-adherence to VTE prophylaxis protocols were significantly reduced during the second period. We conclude that clinical pathways alone are insufficient to improve patient safety and require prospective monitoring and continuous feedback to health care providers in order to achieve the desired effect. PMID:19366438
Current Concepts in Hip Preservation Surgery
Adler, Kelly L.; Cook, P. Christopher; Geisler, Paul R.; Yen, Yi-Meng; Giordano, Brian D.
2016-01-01
Context: Successful treatment of nonarthritic hip pain in young athletic individuals remains a challenge. A growing fund of clinical knowledge has paralleled technical innovations that have enabled hip preservation surgeons to address a multitude of structural variations of the proximal femur and acetabulum and concomitant intra-articular joint pathology. Often, a combination of open and arthroscopic techniques are necessary to treat more complex pathomorphologies. Peri- and postoperative recovery after such procedures can pose a substantial challenge to the patient, and a dedicated, thoughtful approach may reduce setbacks, limit morbidity, and help optimize functional outcomes. Evidence Acquisition: PubMed and CINAHL databases were searched to identify relevant scientific and review articles through December 2014 using the search terms hip preservation, labrum, surgical dislocation, femoroacetabular impingement, postoperative rehabilitation, peri-acetabular osteotomy, and rotational osteotomy. Reference lists of included articles were reviewed to locate additional references of interest. Study Design: Clinical review. Level of Evidence: Level 4. Results: Hip preservation procedures and appropriate rehabilitation have allowed individuals to return to a physically active lifestyle. Conclusion: Effective postoperative rehabilitation must consider modifications and precautions specific to the particular surgical techniques used. Proper postoperative rehabilitation after hip preservation surgery may help optimize functional recovery and maximize clinical success and patient satisfaction. PMID:26733593
Unconstrained tripolar hip implants: effect on hip stability.
Guyen, Olivier; Chen, Qing Shan; Bejui-Hugues, Jacques; Berry, Daniel J; An, Kai-Nan
2007-02-01
Tripolar implants were developed to treat unstable total hip arthroplasties. However, there is limited confirmation that they achieve this purpose despite their increasing use. Because they have a larger effective head size, these implants are expected to increase range of motion to impingement and improve stability in situations at risk for impingement compared with conventional implants. We assessed the range of motion to impingement using a tripolar implant mounted to an automated hip simulator using 22.2-mm and 28-mm femoral head sizes. The 22 and 28-mm tripolar implants provided increases of 30.5 degrees in flexion, 15.4 degrees in adduction, and 22.4 degrees in external rotation compared with the conventional 22.2-mm femoral head diameter implant. At the critical position of 90 degrees hip flexion, there was an increase of 45.2 degrees in internal rotation. At 0 degrees and 30 degrees external rotation, extension increases were 18.8 degrees and 7.8 degrees, respectively. Bony impingement was the limiting factor. Tripolar implants increased the arc of motion before impingement in positions at risk for dislocation and are expected to provide greater stability.
Li, Xigong; Lu, Yang; Sun, Junying; Lin, Xiangjin; Tang, Tiansi
2017-02-01
The purpose of this study was to evaluate the functional and radiographic results of patients with Crowe type-IV hip dysplasia treated by cementless total hip arthroplasty and double chevron subtrochanteric osteotomy. From January 2000 to February 2006, cementless total hip arthroplasty with a double chevron subtrochanteric shortening osteotomy was performed on 18 patients (22 hips) with Crowe type-IV dysplasia. The acetabular cup was placed in the position of the anatomic hip center, and subtrochanteric femoral shortening osteotomy was performed with the use of a double chevron design. The clinical and radiographic outcomes were reviewed with a mean follow-up of 6.5 years (5-10 years). The mean amount of femoral subtrochanteric shortening was 38 mm (25-60 mm). All osteotomy sites were healed by 3-6 months without complications. The mean Harris Hip Score improved significantly from 47 points (35-65 points) preoperatively to 88 points (75-97 points) at the final follow-up. The Trendelenburg sign was corrected from a positive preoperative status to a negative postoperative status in 12 of 22 hips. No acetabular and femoral components have loosened or required revision during the period of follow-up. Cementless total hip arthroplasty using double chevron subtrochanteric osteotomy allowed for restoration of anatomic hip center with safely functional limb lengthening, achieved correction of preoperative limp, and good functional and radiographic outcomes for 22 Crowe type-IV dislocation hips at the time of the 5- to 10-year follow-up. Copyright © 2016 Elsevier Inc. All rights reserved.
Almeida, Gabriel Peixoto Leão; das Neves Rodrigues, Helena Larissa; de Freitas, Bruno Wesley; de Paula Lima, Pedro Olavo
2017-12-01
Study Design Cross-sectional study. Background The Hip Stability Isometric Test (HipSIT) evaluates the strength of the hip posterolateral stabilizers in a position that favors greater activation of the gluteus maximus and gluteus medius and lower activation of the tensor fascia lata. Objectives To check the validity and reliability of the HipSIT and to evaluate the HipSIT in women with patellofemoral pain (PFP). Methods The HipSIT was evaluated with a handheld dynamometer. During testing, the participants were sidelying, with their legs positioned at 45° of hip flexion and 90° of knee flexion. Participants were instructed to raise the knee of the upper leg while keeping the upper and lower heels in contact. To establish reliability and validity, 49 women were tested with the HipSIT by 2 different evaluators on day 1, and then again 7 days later. The strength of the hip extensors, abductors, and external rotators was also evaluated. Twenty women with unilateral PFP were also evaluated. Results The HipSIT has excellent intrarater and interrater reliability. The standard error of measurement was 0.01 kgf/kg, and the minimal detectable change was 0.036 kgf/kg. The HipSIT showed good validity in isolated hip abduction, external rotation, and extension (P<.01). Women with PFP showed a 10% deficit in the HipSIT results for the symptomatic limb (P = .01). Conclusion The HipSIT showed excellent interrater and intrarater reliability, moderate to good validity in women, and was able to identify strength deficits in women with PFP. J Orthop Sports Phys Ther 2017;47(12):906-913. Epub 9 Oct 2017. doi:10.2519/jospt.2017.7274.
Hermanns, Pia; Unger, Sheila; Rossi, Antonio; Perez-Aytes, Antonio; Cortina, Hector; Bonafé, Luisa; Boccone, Loredana; Setzu, Valeria; Dutoit, Michel; Sangiorgi, Luca; Pecora, Fabio; Reicherter, Kerstin; Nishimura, Gen; Spranger, Jürgen; Zabel, Bernhard; Superti-Furga, Andrea
2008-06-01
Deficiency of carbohydrate sulfotransferase 3 (CHST3; also known as chondroitin-6-sulfotransferase) has been reported in a single kindred so far and in association with a phenotype of severe chondrodysplasia with progressive spinal involvement. We report eight CHST3 mutations in six unrelated individuals who presented at birth with congenital joint dislocations. These patients had been given a diagnosis of either Larsen syndrome (three individuals) or humero-spinal dysostosis (three individuals), and their clinical features included congenital dislocation of the knees, elbow joint dysplasia with subluxation and limited extension, hip dysplasia or dislocation, clubfoot, short stature, and kyphoscoliosis developing in late childhood. Analysis of chondroitin sulfate proteoglycans in dermal fibroblasts showed markedly decreased 6-O-sulfation but enhanced 4-O-sulfation, confirming functional impairment of CHST3 and distinguishing them from diastrophic dysplasia sulphate transporter (DTDST)-deficient cells. These observations provide a molecular basis for recessive Larsen syndrome and indicate that recessive Larsen syndrome, humero-spinal dysostosis, and spondyloepiphyseal dysplasia Omani type form a phenotypic spectrum.
Pappas, Evangelos; Orishimo, Karl F; Kremenic, Ian; Liederbach, Marijeanne; Hagins, Marshall
2012-05-01
Retrospective studies have suggested that dancers performing on inclined ("raked") stages have increased injury risk. One study suggests that biomechanical differences exist between flat and inclined surfaces during bilateral landings; however, no studies have examined whether such differences exist during unilateral landings. In addition, little is known regarding potential gender differences in landing mechanics of dancers. Professional dancers (N = 41; 14 male, 27 female) performed unilateral drop jumps from a 30 cm platform onto flat and inclined surfaces while extremity joint angles and moments were identified and analyzed. There were significant joint angle and moment effects due to the inclined flooring. Women had significantly decreased peak ankle dorsiflexion and hip adduction moment compared with men. Findings of the current study suggest that unilateral landings on inclined stages create measurable changes in lower extremity biomechanical variables. These findings provide a preliminary biomechanical rationale for differences in injury rates found in observational studies of raked stages.
Imaizumi, Mitsuyoshi; Li-Jessen, Nicole Y K; Sato, Yuka; Yang, David T; Thibeault, Susan L
2017-04-01
One prospective treatment option for vocal fold scarring is regeneration with an engineered scaffold containing induced pluripotent stem cells (iPS). In the present study, we investigated the feasibility of utilizing an injectable hyaluronic acid (HA) scaffold encapsulated with human-iPS cell (hiPS) for regeneration of vocal folds. Thirty athymic nude rats underwent unilateral vocal fold injury. Contralateral vocal folds served as uninjured controls. Hyaluronic acid hydrogel scaffold, HA hydrogel scaffold containing hiPS, and HA hydrogel scaffold containing hiPS with epidermal growth factor (EGF) were injected in both vocal folds immediately after surgery. One and 2 weeks after injection, larynges were excised for histology, immunohistochemistry, and fluorescence in situ hybridization (FISH). Presence of HA hydrogel was confirmed in vocal folds 1 and 2 weeks post injection. The FISH analysis confirmed the presence and viability of hiPS in the injected vocal folds. Histological results demonstrated that vocal folds injected with HA hydrogel scaffold containing EGF demonstrated less fibrosis than those with HA hydrogel only. Human-iPS survived in injured rat vocal folds. The HA hydrogel with hiPS and EGF ameliorated the fibrotic response. Additional work is necessary to optimize hiPS differentiation and further confirm the safety of hiPS for clinical applications.
Tsai, Tsung-Yuan; Dimitriou, Dimitris; Li, Jing-Sheng; Kwon, Young-Min
2016-06-01
The objective was to evaluate whether total hip arthroplasty (THA) using haptic robot assistance restores hip geometry better than the free-hand technique. Twelve robot-assisted and 14 free-hand unilateral THA patients underwent CT scan for three-dimensional (3D) hip models. The anteversion, inclination and hip joint centre locations of the native and implanted hips in each patient were quantified and compared. Significant increase of combined anteversion by 19.1 ± 11.7° and 23.5 ± 23.6° and decrease of cup inclination by 16.5 ± 6.0° and 10.2 ± 6.8° were observed in the robot-assisted and the free-hand THAs, respectively. Less variation in the difference of the component orientations (max 11.1 vs 18.3°) and the femoral head centre (max 4.5 vs 6.3 mm) were found in the robot-assisted group. This study demonstrated that neither robot-assisted nor free-hand THAs had fully restored native hip geometry. However, the higher precision of the robot-assisted THA suggested that it has potential utility in restoring the native hip geometry. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
Yang, Li-qing; Li, Xi; Fu, Qin; Wang, Cheng
2013-07-01
To retrospectively study early therapeutic effects of the ceramics to ceramics prosthesis design in treating hip disease. From October 2007 to September 2010, 42 patients (44 hips) with hip disease underwent replacement of total hip. Hip prosthesis designs included the Pinnacle ceramics to ceramics and the Duraloc metal to polyethylene,produced by DePuy Company, all were non-bone cement type of artificial hip joint. Twenty patients (22 hips) were performed with ceramics to ceramics total hip prosthesis (CoC group, there were 12 males and 8 females, aged from 21 to 49 years) and 22 patients (22 hips) were performed with metal to polyethylene total hip prosthesis (MoP group, there were 13 males and 9 females, aged from 42 to 55 years). All the surgical approachs were posterolateral, and the routine anticoagulation and the corresponding functional exercise were performed after operation. The follow-up time was 6 months at least including clinical and radiographic observation. Measured the motion of joint and evaluated the function of hip joint according to Harris classification. All clinical effects were satisfactory and no dislocation ,loosening,infection, deep venous thrombosis and other complications occurred. There was no statistical significance in Harris scoring and the motion of joint between two groups before and after operation (P>0.05). The clinical effect of ceramics to ceramics prosthesis design in improving clinical symptoms and the motion of joint is coordinate with metal to polyethylene total hip prosthesis, however, its advantages and long-term efficacy need further observing. The ceramics to ceramics prosthesis design may be a good choice for the young patients with hip disease because of its good wear resistance.
Dual Mobility Cemented Cups Have Low Dislocation Rates in THA Revisions
Langlais, Frantz L.; Gaucher, François; Musset, Thierry; Chaix, Olivier
2008-01-01
THA revisions using standard cups are at risk of dislocation (5.1% to 14.4% incidence), especially in patients over 70 years of age. Constrained tripolar cups have reduced this risk (6% incidence) but are associated with substantial loosening rates (9%). The nonconstrained dual mobility cup was designed to improve prosthetic stability (polyethylene head ≥ 40 mm diameter) without increasing loosening rates by reducing wear and limiting impingement (rotation range of 108°). We implanted 88 cemented dual mobility cups for THA revisions in 82 patients at high risk of dislocation. Average patient age was 72 years (range, 65–86 years). Eighty-five of the 88 hips were reviewed at 2 to 5 years followup. One patient (1.1%) had a traumatic dislocation at 2 years postoperatively. Two patients (2.3%) had asymptomatic early loosening and three patients (3.5%) had localized radiographic lucencies. These results confirm those with press-fit dual mobility cups suggesting a low dislocation rate at 5 years and a cup survival of 94.6%. At middle term followup, cemented dual mobility cup achieved better results than constrained cups in cases at risk of dislocation and recurrent loosening. Level of Evidence: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence. PMID:18196422
Amaral, Márcio Bruno; Bueno, Sebastião Cristian; Silva, Alice Araújo Ferreira; Mesquita, Ricardo Alves
2011-06-01
Superolateral dislocation of the intact mandibular condyle (SDIMC) is rare. This case report focuses on a 15-year-old teenager who was involved in a motor vehicle accident as well a literature review regarding the SDIMC. Clinical examination demonstrated a diffuse edema in the midfacial area and a left lateral deflection of the mandible, including an open bite and a crepitation in the symphyseal region. Three-dimensional computed tomography scans were taken, which presented a superolateral dislocation of the left mandibular condyle as well as panfacial fracture. The patient was set in intermaxillary fixation for 2 weeks and underwent subsequent active jaw physiotherapy, the evaluation of which presented satisfactory results. This case study also presents a literature review, which demonstrated 21 well-documented cases of SDIMC. The patients' mean age was of 29 years. The male gender proved to be more prevalent, with road traffic collisions representing the most common form of accident. Type II, with unilateral dislocation, proved to be the most common. The mean reduction time was 7 days. The open methods were the most commonly used reduction methods. Mandible fracture was associated with dislocation in 82% of the cases, with other facial fractures appearing in only 23% of the cases. Patient follow up presented satisfactory results in 59% of the cases. © 2011 John Wiley & Sons A/S.
Quantification of Femoral Neck Exposure Through a Minimally Invasive Smith-Petersen Approach
2010-06-01
Gautier E, et al. Surgical dislocation of the adult hip: A technique with full access to femoral head and acetabulum without the risk of avascular ... necrosis . J Bone Joint Surg (Br). 2001;83:1119 1124. 24. Gautier E, Ganz K, Krugel N, et al. Anatomy of the medial femoral circumflex artery and its
Du, Wei; Wang, Cheng; Tan, Jiangwei; Shen, Binghua; Ni, Shuqin; Zheng, Yanping
2014-01-01
Retrospective case series. To discuss the clinical efficacy of anterior cervical surgery of decompression, reduction, stabilization, and fusion in treating subaxial cervical facet dislocation without spinal cord injury or with mild spinal cord injury monitored by spinal cord evoked potential. The optimal treatment of lower cervical facet dislocation has been controversial. Because of the risk of iatrogenic damage of neurological function, it is challenging for surgeons to manage the lower cervical facet dislocation without or with mild spinal cord injury. To avoid the risks, more secure strategy need to be designed. A retrospective study was performed on 17 cases of subaxial cervical facet dislocation without spinal cord injury or with mild spinal cord injury treated by anterior cervical surgery under spinal cord evoked potential monitor from January 2008 to June 2012. There were 12 males, 5 females, with a mean age of 40.1 years (from 21 to 73 yr). Dislocation sites: 1 in C3-C4, 2 in C4-C5, 6 in C5-C6, 8 in C6-C7; 10 cases with unilateral cervical facet dislocation, 7 cases with bilateral dislocation. Thirteen patients were preoperatively classified as grade D and 4 as E according to Frankel standard. All patients were followed up for average of 16 months. All operations were completed successfully. Postoperative radiographs showed that the sequence and curvature of the cervical spine were well recovered. And, evidence of intervertebral fusion was observed at 3 months in all cases. No redislocation or symptoms of spinal cord injury occurred. Thirteen cases with mild spinal cord injury recovered at 1 month after operation. Anterior cervical surgery of decompression, reduction, stabilization, and fusion monitored by spinal cord evoked potential is an effective and safe method for treatment of subaxial cervical facet dislocation without or with mild spinal cord injury. 4.
Jungmann, P M; Nevitt, M C; Baum, T; Liebl, H; Nardo, L; Liu, F; Lane, N E; McCulloch, C E; Link, T M
2015-07-01
To evaluate the association of prevalent unilateral total hip arthroplasty (THA) with worsening of degenerative knee abnormalities and clinical outcomes in the ipsilateral and contralateral knee. Both knees of 30 individuals in the Osteoarthritis Initiative (OAI) with unilateral THA (n = 14 left, n = 16 right) at baseline were assessed at baseline and at 4-year follow-up for Whole-organ MR Imaging Scores (WORMS), cartilage T2 relaxation times (only available for right knees), Western Ontario and McMasters Universities Arthritis Index (WOMAC) scores and upper leg isometric strength. Right knees of 30 individuals without THA were analyzed as controls. Contralateral knees were compared to ipsilateral knees with paired t-tests and to control knees with multivariate regression analysis adjusting for covariates. In paired analyses, compared to ipsilateral knees, contralateral knees had higher WORMS total (P = 0.008) and cartilage scores (P = 0.007) at baseline. Over 4 years contralateral knees worsened more on WORMS total score (P = 0.008). Cartilage T2 values were higher in knees contralateral to the THA (baseline, P = 0.02; follow-up, P < 0.001). Contralateral knees had greater declines in knee extension strength (P = 0.04) and had a trend for greater worsening in WOMAC pain, stiffness, function and total scores (P = 0.04-0.09). Similar results were found comparing contralateral knees with control knees in multivariate regression models. Prevalent unilateral THA is associated with an greater progression of degenerative findings for the knee contralateral to THA. Copyright © 2015 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Levine, Brett R; Della Valle, Craig J; Deirmengian, Carl A; Breien, Kristoffer M; Weeden, Steven H; Sporer, Scott M; Paprosky, Wayne G
2008-12-01
A retrospective cohort study of 31 hips revised with a tripolar articular construct was performed. Patient demographics and preoperative and postoperative information were recorded. Indications for a tripolar construct were recurrent dislocation and the inability to attain intraoperative stability during hip revision. Nine patients (29%) were revised to the tripolar construct after failure of a constrained liner. Twenty patients (65%) had at least one episode of instability before the most recent revision. At a mean follow-up of 38 months, modified Postel scores improved from a mean of 5.28 to 9.64 (P < .01). Radiographic follow-up revealed no evidence of component loosening/migration, osteolysis, or polyethylene wear. Two patients (7%) required further revision surgery for recurrent instability. A tripolar construct was effective in eliminating or preventing instability in 93% of the complex cases treated. These early results support the use of a tripolar construct in treating recurrent instability or instability encountered at the time of revision hip arthroplasty.
Legenstein, R; Huber, W; Ungersboeck, A; Boesch, P
2006-01-01
From 1990 to 1991 we implanted 176 non-cemented proximal press-fit (PPF) total hip arthroplasties (THA) with ceramic-on-polyethylene articulation in 170 patients. Of these, 119 patients (122 THA) were followed from 104 to 129 months. Four cups have been revised for aseptic loosening, but revealed no radiolucencies of the stem. Two infections and two dislocations occurred. The median postoperative Harris hip score was 91. Ninety-eight per cent of the patients were satisfied with the outcome, 83% were free of pain and 67% walked without a limp. Serial radiographs showed stable fixation with bone ongrowth in nearly all arthroplasties except for four cups. Stem radiolucencies were first seen within 12 months, but were of no clinical relevance. Proximal periprosthetic bone resorption of the stem was seen in 18%. Radiolucencies occurred because of polyethylene debris-induced granulomas. The PPF system yields satisfactory long-term results in patients with primary and secondary hip osteoarthritis and dysplasia.
Biomechanical differences between unilateral and bilateral landings from a jump: gender differences.
Pappas, Evangelos; Hagins, Marshall; Sheikhzadeh, Ali; Nordin, Margareta; Rose, Donald
2007-07-01
To determine the effect of landing type (unilateral vs. bilateral) and gender on the biomechanics of drop landings in recreational athletes. This study used a repeated measures design to compare bilateral and unilateral landings in male and female athletes. A repeated measures multivariate analysis of variance (type of landing*gender) was performed on select variables. Biomechanics laboratory. Sixteen female and 16 male recreational athletes. Kinetic, kinematic, and electromyographic (EMG) data were collected on participants while performing bilateral and unilateral landings from a 40-cm platform. Compared to bilateral landings, subjects performed unilateral landings with increased knee valgus, decreased knee flexion at initial contact, decreased peak knee flexion, decreased relative hip adduction, and increased normalized EMG of the rectus femoris, medial hamstrings, lateral hamstrings, and medial gastrocnemius (P < 0.005). During both types of landing, females landed with increased knee valgus and normalized vertical ground reaction force (VGRF) compared to males (P < 0.009), however, the interaction of landing type*gender was not significant (P = 0.29). Compared to bilateral landings, male and female recreational athletes performed unilateral landings with significant differences in knee kinematic and EMG variables. Female athletes landed with increased knee valgus and VGRF compared to males during both types of landing.
2015-10-01
of proximal compensations (e.g., hip-hiking) to assist with toe clearance (Michaud et al., 2000), or simply because these individuals feel more...related unilateral lower extremity amputation: a long-term survey in a prosthesis center in Iran. Journal of orthopaedic trauma 23(7), 525-530
Magnetic resonance imaging with gadolinium arthrography to assess acetabular cartilage delamination.
Zaragoza, Edward; Lattanzio, Pierre-Jean; Beaule, Paul E
2009-01-01
Recent reports have demonstrated magnetic resonance imaging (MRI) as a promising technique in detecting articular cartilage lesions of the hip joint. The purpose of our study was to evaluate the diagnostic performance of MRI with gadolinium arthrography in detecting acetabular cartilage delamination in patients with pre-arthritic hip pain. 46 patients (48 hips) underwent surgical dislocation of the hip. Mean age was 38.8 (range 17-56). There were 26 males and 20 females. All patients had Magnetic Resonance Imaging with gadolinium arthrography (MRA) before undergoing open hip surgery where the acetabular cartilage was inspected. Acetabular cartilage delamination on MRA was seen on sagittal images as a linear intra-articular filling defect of low signal intensity >1mm in thickness on T1 weighted images and surrounded by contrast. On MRA all hips had a labral tear confirmed at surgery. At surgery 30 hips had evidence of acetabular cartilage delamination, 4 hips had ulceration and 14 had no articular cartilage damage. The majority of labral tears and cartilage damage were located in the antero-superior quadrant. The sensitivity and specificity of MRA detection of cartilage delamination confirmed at surgery were 97% and 84%, respectively. The positive and negative predictive values of the MRA finding were 90% and 94%, respectively. The presence of the acetabular cartilage delamination represents an early stage of articular cartilage degeneration. When evaluating a young adult with hip pain, labral tears in association with cartilage delamination should be considered. MRA represents an effective diagnostic tool.
Lungu, E; Maftoon, S; Vendittoli, P-A; Desmeules, F
2016-05-01
Although generally considered successful, total hip arthroplasty (THA) can yield suboptimal results in terms of pain and function in up to one forth of patients suffering from hip osteoarthritis (OA). A thorough understanding of the determinants of patient-reported pain and function following THA can help plan interventions directed at improving surgical results. Previously published systematic reviews do not permit to confidently identify the determinants of THA outcomes because of unsatisfactory methodological designs. Therefore, we aimed to answer: (1) which preoperative factors are most consistently associated with postoperative patient-reported pain and function up to 2 years following primary unilateral THA for hip OA. Medline, Pubmed, Embase and CINAHL were screened from their respective inception dates until April 2015 using a combination of keywords and MESH terms. Criteria for inclusion were: (1) participants with primary unilateral THA for hip OA followed for at least 3 months with a maximal follow-up of 2 years; (2) validated disease-specific patient-reported outcome measures assessing pain and/or disability; (3) identification of determinants obtained via multivariate analyses. Methodological quality was assessed using a modified version of the methodology checklist for prognostic studies. Twenty-two manuscripts were included. Mean score of the methodological quality was 81.0±10.3% (66.7% to 100%). Among socioeconomic determinants, a lower educational level was significantly related to worse pain and function (3 out of 3 studies evaluating the relationship). Clinical determinants of poor outcomes included preoperative levels of pain and physical function (9 out of 12 studies), higher body mass index (6 out of 10 studies), presence/greater level of comorbidities (7 out of 8), worse general health (4 out of 4 studies) and lower radiographic OA severity (3 out of 4 studies). Study heterogeneity limited the pooled assessment of the strength of associations between the preoperative variables and THA outcomes. Studies with moderate-to-high methodological quality allowed to identify 6 preoperative variables consistently associated with medium term pain and function following THA. This knowledge may assist the management of patients at risk of poor results. Further research is required to clarify the force of associations between determinants and THA outcomes. Level II. Systematic review of cohort studies. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Sobhan, Mohammad R; Abrisham, Seyed Mohammad J; Vakili, Mahmood; Shirdel, Saeed
2016-10-01
Pelvic ring injuries and sacroiliac dislocations have significant impacts on patient's quality of life. Several techniques have been described for posterior pelvic fixation. The current study has been designed to evaluate the spinopelvic method of fixation for sacroiliac fractures and fracture-dislocations. Between January 2006 and December 2014, 14 patients with sacroiliac joint fractures, dislocation and fracture-dislocation were treated by Spinopelvic fixation at Shahid Sadoughi Training Hospital, Yazd, Iran. Patients were seen in follow up, on average, out to 32 months after surgery. Computed tomographic (CT) scans of patients with sacral fractures were reviewed to determine the presence of injuries. A functional assessment of the patients was performed using Majeed's score. Patient demographics, reduction quality, loss of fixation, outcomes and complications, return to activity, and screw hardware characteristics are described. The injury was unilateral in 11 (78.5%) patients and bilateral in 3 (21.5%). Associated injuries were present in all patients, including fractures, dislocation and abdominal injuries. Lower limb length discrepancy was less than 10 mm in all patients except two. Displacement, as a measure of quality of reduction was less than 5 mm in 13 patients. The mean Majeed score was 78/100. Wound infection and hardware failure were observed in 3 (21.4%) and 1 (7.1%) cases, respectively. In this study most patients (85%) return to work postoperatively. According to the findings, spinopelvic fixation is a safe and effective technique for treatment of sacroiliac injuries. This method can obtain early partial to full weight bearing and possibly reduce the complications.
TEM study on relationship between stacking faults and non-basal dislocations in Mg
NASA Astrophysics Data System (ADS)
Zhang, Dalong; Jiang, Lin; Schoenung, Julie M.; Mahajan, Subhash; Lavernia, Enrique J.
2015-12-01
Recent interest in the study of stacking faults and non-basal slip in Mg alloys is partly based on the argument that these phenomena positively influence mechanical behaviour. Inspection of the published literature, however, reveals that there is a lack of fundamental information on the mechanisms that govern the formation of stacking faults, especially I1-type stacking faults (I1 faults). Moreover, controversial and sometimes contradictory mechanisms have been proposed concerning the interactions between stacking faults and dislocations. Therefore, we describe a fundamental transmission electron microscope investigation on Mg 2.5 at. % Y (Mg-2.5Y) processed via hot isostatic pressing (HIP) and extrusion at 623 K. In the as-HIPed Mg-2.5Y, many
[Efficacy analysis on hip replacement for hip-joint diseases with Parkinson disease].
Sun, Qi-Cai; Ru, Xuan-Liang; Xia, Yan-Fei; Liu, Xiao-Li; Song, Bai-Shan; Qiao, Song; Yan, Shi-Gui; Wang, Xiang-Hua
2017-12-25
To explore clinical efficacy of hip replacement for hip-joint diseases with Parkinson disease. From December 2011 to December 2016, 18 patients with hip-joint diseases with Parkinson disease treated by hip replacement, including 8 males and 10 females aged from 59 to 87 years old with an average of 71 years old. Among them, 3 cases were developmental dysplasia of hip, 3 cases were femoral head necrosis and 12 cases were femoral neck fracture. All patients manifested with obvious pain and limitation of stepping ability. Postoperative complications were observed and Harris score were used to compare hip joint function after operation. The incision were healed well, and pain were alleviated or disappeared, and hip joint function were improved. Eighteen patients were followed up from 1 to 3 years with an average of 2.3 years. At the latest follow up, 14 cases recovered freedom-walk, 2 cases could walk with walking stick, 1 case could walk with walking aid and 1 case was died. Among 18 patients, 2 cases were occurred dislocation, and 1 case were died for cardiac disease at 3 months after operation. Four patients were occurred slight pain. There were significant differences in Harris scores among preoperative (41.7±1.4), 6 months after operation(80.1±5.4) and the final follow-up (83.4±2.1), and 10 cases got excellent result, 4 good, 1 fair and 2 poor. Application of hip replacement for hip-joint diseases with Parkinson disease is a safe and effective clinical therapy, and has advantages of less complications and rapid recovery of hip joint function.
[Which hip articulation bearing for which patient? : Tribology of the future].
Morlock, M M; Bishop, N; Kaddick, C
2011-12-01
Replacement of the hip joint has become an exceptionally successful procedure since the inauguration of the low friction principle by Charnley. Aseptic osteolysis and joint dislocation have been addressed by the development of wear-optimized materials and the introduction of larger heads. As an increase in head diameter against polyethylene causes wear increase, larger hard-on-hard bearings were introduced, which exhibit reduced wear and reduced dislocation risk with increasing head diameter. These findings were derived from standard simulator testing, not sufficiently considering the risk of fluid film breakdown under adverse conditions, which can cause a dramatic increase in wear and friction proportional to the head diameter. Such adverse conditions can occur clinically in patients due to several factors and have caused the presently observed unexpected problems with these new designs. Standardized preclinical testing has to be viewed as a minimum requirement but certainly not as a guarantee for the clinical success of new materials and designs even if the testing is adapted to the current patient requirements, which is presently not the case. The future of tribology lies in the prevention of adverse conditions in patients, the improvement and optimized use of proven existing materials and not in the use of new materials.
Microstructure and Charpy impact properties of 12 14Cr oxide dispersion-strengthened ferritic steels
NASA Astrophysics Data System (ADS)
Oksiuta, Z.; Baluc, N.
2008-02-01
This paper describes the microstructure and Charpy impact properties of 12-14 Cr ODS ferritic steels fabricated by mechanical alloying of pure Fe, Cr, W, Ti and Y 2O 3 powders in a Retsch ball mill in argon atmosphere, followed by hot isostatic pressing at 1100 °C under 200 MPa for 4 h and heat treatment at 850 °C for 1 h. Weak Charpy impact properties were obtained in the case of both types of as-hipped materials. In the case of 14Cr materials, the weak Charpy properties appeared related to a bimodal grain size distribution and a heterogeneous dislocation density between the coarse and fine grains. No changes in microstructure were evidenced after heat treatment at 850 °C. Significant improvement in the transition temperature and upper shelf energy of 12Cr materials was obtained by heat treatment at 850 °C for 1 h, which was attributed to the formation of smaller grains, homogenous in size and containing fewer dislocations, with respect to the as-hipped microstructure. This modified microstructure results in a good compromise between strength and Charpy impact properties.
Zhang, Hua; Xu, Zhongwei; Zhou, Aiguo; Yan, Wenlong; Zhao, Pei; Huang, Xiao; Zhang, Jian
2017-01-01
Abstract The aim of this study was to evaluate the efficacy of supplementary fixation in hip arthroplasty with the use of Kirschner-wires and tension band for geriatric patients suffering unstable intertrochanteric osteoporotic fractures. A total of 103 patients aged more than 75 years were recruited. A bipolar or total hip replacement was performed with additional application of Kirschner-wires and tension band, and the participants were followed up for 2 to 11 years. Physical component summary (PCS), mental component summary (MCS), visual analog scale (VAS), and Harris hip score were utilized to evaluate patients’ hip pain and function, as well as the mental condition postoperatively after 1.5 months, 3 months, 6 months, 1 year, and annually thereafter until the latest follow-up in 2015. Patients showed a significant improvement in all scores between 1.5 months and 1 year (P < 0.001), with the good efficacy lasting at least until the 2-year follow-up. None of the patients showed dislocation, implant loosening, or nonunion of the fracture throughout the follow-up period. In conclusion, it was beneficial to treat unstable intertrochanteric osteoporotic fractures in aged patients with hip arthroplasty coupled with Kirschner-wires and tension band. PMID:28072698
Effects of Imbalanced Muscle Loading on Hip Joint Development and Maturation
Ford, Caleb A.; Nowlan, Niamh C.; Thomopoulos, Stavros; Killian, Megan L.
2017-01-01
The mechanical loading environment influences the development and maturation of joints. In this study, the influence of imbalanced muscular loading on joint development was studied using localized chemical denervation of hip stabilizing muscle groups in neonatal mice. It was hypothesized that imbalanced muscle loading, targeting either gluteal muscles or quadriceps muscles, would lead to bilateral hip joint asymmetry, as measured by acetabular coverage, femoral head volume and bone morphometry, and femoral-acetabular shape. The contralateral hip joints as well as age-matched, uninjected mice were used as controls. Altered bone development was analyzed using micro-computed tomography, histology, and image registration techniques at postnatal days (P) 28, 56, and 120. This study found that unilateral muscle unloading led to reduced acetabular coverage of the femoral head, lower total volume, lower bone volume ratio, and lower mineral density, at all three time points. Histologically, the femoral head was smaller in unloaded hips, with thinner triradiate cartilage at P28 and thinner cortical bone at P120 compared to contralateral hips. Morphological shape changes were evident in unloaded hips at P56. Unloaded hips had lower trabecular thickness and increased trabecular spacing of the femoral head compared to contralateral hips. The present study suggests that decreased muscle loading of the hip leads to altered bone and joint shape and growth during postnatal maturation. Statement of Clinical Significance: Adaptations from altered muscle loading during postnatal growth investigated in this study have implications on developmental hip disorders that result from asymmetric loading, such as patients with limb-length inequality or dysplasia. PMID:27391299
Medium-term outcome in patients treated with total hip arthroplasty using a modular femoral stem.
Dagnino, Augusto; Grappiolo, Guido; Benazzo, Franco M; Learmonth, Ian D; Spotorno, Lorenzo; Portinaro, Nicola
2012-01-01
The clinical, radiographic and quality of life results of total hip arthroplasty using the MODULUS cementless modular femoral stem were reviewed. 48 patients who had a total hip arthroplasty using the MODULUS femoral stem were identified. Six had bilateral procedures, resulting in 60 hips with complete clinical and radiographic data. Mean age at implantation was 50 years (range 33 to 82). Mean follow-up was 59 months (range 50 months to 73). There were two early post-operative dislocations (within 2 days). One patient required further surgery to remove heterotopic bone. Mean Harris Hip Score increased from 37 points preoperatively (range, 7 to 66) to 89 points at final review (range, 65 to 100 points). Radiographic evaluation revealed that all implants were stable without evidence of osteolysis but three patients (5%) exhibited heterotopic ossification. Quality of life was evaluated with the SF36. The physical component increased from 29.2 points (range, 18.5 to 46.0) to 51.7 points (range 42.9 to 60.6) and the mental component from 375 points (range, 19.5 to 50.0) to 50 points (range 32,8 to 62.0).
Hip joint replacement using monofilament polypropylene surgical mesh: an animal model.
Białecki, Jacek; Majchrzycki, Marian; Szymczak, Antoni; Klimowicz-Bodys, Małgorzata Dorota; Wierzchoś, Edward; Kołomecki, Krzysztof
2014-01-01
Hip joint dysplasia is a deformation of the articular elements (pelvic acetabulum, head of the femur, and/or ligament of the head of the femur) leading to laxity of the hip components and dislocation of the femoral head from the pelvic acetabulum. Diagnosis is based on symptoms observed during clinical and radiological examinations. There are two treatment options: conservative and surgical. The classic surgical procedures are juvenile pubic symphysiodesis (JPS), triple pelvic osteotomy (TPO), total hip replacement (THR), and femoral head and neck resection (FHNE). The aim of this experiment was to present an original technique of filling the acetabulum with a polypropylene implant, resting the femoral neck directly on the mesh. The experiment was performed on eight sheep. The clinical value of the new surgical technique was evaluated using clinical, radiological, and histological methods. This technique helps decrease the loss of limb length by supporting the femoral neck on the mesh equivalent to the femoral head. It also reduces joint pain and leads to the formation of stable and mobile pseudarthrosis. The mesh manifested osteoprotective properties and enabled the formation of a stiff-elastic connection within the hip joint. The method is very cost-effective and the technique itself is simple to perform.
Kang, Jeong Hoon; Lee, Sang Hong; Jung, Sung
2015-12-01
The current study aims to evaluate the clinical and the radiological outcome of bipolar hemiarthroplasty using cementless cone stem to treat osteoporotic femoral neck fracture and compare the results according to the proximal femur geometry. Seventy-five hips (75 patients) that underwent bipolar hemiarthroplasty with cementless cone stem between September 2006 and December 2011 were analyzed. The minimum follow-up period was 3 years. Thirty-three hips were classified as type B and 41 as type C. The clinical outcome was assessed using Harris hip score and the walking ability score. Radiographic evaluation was performed to evaluate the stability of the prosthesis. At the most recent follow up, the mean Harris hip score was 86 (range, 70-92) and 65% recovered to preoperative ambulatory status. In the radiographic exam, stable stem fixation was achieved in all cases. For the complications, eight hips developed deep vein thrombosis while three hips showed heterotopic ossification. Dislocation and delayed deep infection occurred in one hip resepectively. There were no significance differences in Harris hip score and walking ability score when the type B group was compare with the type C. Bipolar hemiarthroplasty with cementless cone stem showed an excellent early outcome both clinically and radiographically regardless of the shape of the proximal femur. We believe this prosthesis can provide early stability to the Dorr type B and C femur and is an effective treatment for treating osteoporotic femoral neck fracture.
Estébanez-de-Miguel, Elena; Fortún-Agud, María; Jimenez-Del-Barrio, Sandra; Caudevilla-Polo, Santos; Bueno-Gracia, Elena; Tricás-Moreno, José Miguel
2018-05-29
Manual therapy has been shown to increase range of motion (ROM) in hip osteoarthritis (OA). However, the optimal intensity of force during joint mobilization is not known. To compare the effectiveness of high, medium and low mobilization forces for increasing range of motion (ROM) in patients with hip OA and to analyze the effect size of the mobilization. Randomized controlled trial. Sixty patients with unilateral hip OA were randomized to three groups: low, medium or high force mobilization group. Participants received three treatment sessions of long-axis distraction mobilization (LADM) in open packed position and distraction forces were measured at each treatment. Primary outcomes: passive hip ROM assessed before and after each session. pain recorded with Western Ontario and McMaster Universities (WOMAC) pain subscale before and after the three treatment sessions. Hip ROM increased significantly (p < 0.05) in the high-force mobilization group (flexion: 10.6°, extension: 8.0°, abduction:6.4°, adduction: 3.3°, external rotation: 5.6°, internal rotation: 7.6°). These improvements in hip ROM were statistically significant (p < 0.05) compared to the low-force group. There were no significant changes in the low-force and medium-force groups for hip ROM. No significant differences in hip pain were found between treatment groups. A high force LADM in open packed position significantly increased hip ROM in all planes of motion compared to a medium or low force mobilization in patients with hip OA. A specific intensity of force mobilization appears to be necessary for increasing ROM in hip OA. Copyright © 2018 Elsevier Ltd. All rights reserved.
Li, Qiwei; Kadhim, Muayad; Zhang, Lijun; Cheng, Xiangjun; Zhao, Qun; Li, Lianyong
2014-12-01
Few reports are available describing knee changes in neglected developmental dysplasia of the hip (DDH). The purpose of this study was to assess the radiographic morphology of knee joints in adults with neglected DDH. Thirty-seven patients (35 females and two males) with neglected DDH were prospectively recruited with an average age of 32.6 years. Twenty-three patients had unilateral and 14 patients had bilateral neglected DDH. Thirty-seven healthy individuals were recruited to form a matched control group. Three groups of knee joints were examined: affected knees (on the same side of the neglected DDH), unaffected knees (contralateral to the neglected DDH in patients with unilateral involvement), and control knees. A series of radiographic parameters of the knee joint were measured in the coronal and sagittal plane, and they were compared between patients and normal controls. In the coronal plane, the affected knees had increased valgus angulation related to increased height of the medial femoral condyle, decreased height of the lateral femoral condyle and decreased lateral distal femoral angle compared to control knees. In the sagittal plane, both distal femoral and proximal tibial joints of the affected knees developed a decrease in posterior angles. Additionally, the unaffected knees also developed radiographic changes compared to control knees. Patients with neglected DDH may develop changes in both knee joints. These changes should be considered during surgery to the hip, femur and knee to prevent potential complications. Level 2. Copyright © 2014 Elsevier B.V. All rights reserved.
Daneshjoo, Abdolhamid; Rahnama, Nader; Mokhtar, Abdul Halim; Yusof, Ashril
2013-01-01
This study investigated bilateral and unilateral asymmetries of strength and flexibility in male young professional soccer players. Thirty-six soccer players (age: 18.9 ± 1.4 years) participated in this study. A Biodex Isokinetic Dynamometer was used to assess the hamstring and quadriceps strength at selected speeds of 60°/s, 180°/s and 300°/s. Hip joint flexibility was measured using a goniometer. No difference was observed in conventional strength ratio, dynamic control ratio and fast/slow speed ratio between the dominant and non-dominant legs (p>0.05). All but one of the players (97.2%) had musculoskeletal abnormality (bilateral imbalance > 10%) in one or more specific muscle groups. The dominant leg had greater hip joint flexibility compared with the non-dominant leg (108.8 ± 10.7° versus 104.6 ± 9.8°, respectively). The findings support the hypothesis that physical performance and movement pattern experienced during soccer playing may negatively change the balance of strength in both legs (bilateral strength balance), but not on the same leg of the young male professional soccer players. The results can be helpful for trainers and coaches to decide whether the players need to improve their balance and strength which in turn may prevent injury. It is suggested that in professional soccer training, quadriceps and hamstrings muscle strength, as well as hip joint flexibility should not be overlooked. PMID:23717354
3D surgical printing and pre contoured plates for acetabular fractures.
Chana-Rodríguez, Francisco; Mañanes, Rubén Pérez; Rojo-Manaute, José; Gil, Pablo; Martínez-Gómiz, José María; Vaquero-Martín, Javier
2016-11-01
We describe the methodical and possibilities of 3D surgical printing in preoperative planning of acetabular fractures showing a case of a 45-year-old with an associated transverse fracture of the left acetabulum with posterior wall fracture, with multiple fragments, and posterior ipsilateral hip dislocation, defending the do it your-self mode. Copyright © 2016 Elsevier Ltd. All rights reserved.
EMG of the hip adductor muscles in six clinical examination tests.
Lovell, Gregory A; Blanch, Peter D; Barnes, Christopher J
2012-08-01
To assess activation of muscles of hip adduction using EMG and force analysis during standard clinical tests, and compare athletes with and without a prior history of groin pain. Controlled laboratory study. 21 male athletes from an elite junior soccer program. Bilateral surface EMG recordings of the adductor magnus, adductor longus, gracilis and pectineus as well as a unilateral fine-wire EMG of the pectineus were made during isometric holds in six clinical examination tests. A load cell was used to measure force data. Test type was a significant factor in the EMG output for all four muscles (all muscles p < 0.01). EMG activation was highest in Hips 0 or Hips 45 for adductor magnus, adductor longus and gracilis. EMG activation for pectineus was highest in Hips 90. Injury history was a significant factor in the EMG output for the adductor longus (p < 0.05), pectineus (p < 0.01) and gracilis (p < 0.01) but not adductor magnus. For force data, clinical test type was a significant factor (p < 0.01) with Hips 0 being significantly stronger than Hips 45, Hips 90 and Side lay. BMI (body mass index) was a significant factor (p < 0.01) for producing a higher force. All other factors had no significant effect on the force outputs. Hip adduction strength assessment is best measured at hips 0 (which produced most force) or 45° flexion (which generally gave the highest EMG output). Muscle EMG varied significantly with clinical test position. Athletes with previous groin injury had a significant fall in some EMG outputs. Copyright © 2011 Elsevier Ltd. All rights reserved.
Haen, T X; Lonjon, G; Vandenbussche, E
2015-12-01
Cemented versions of dual-mobility cups (DMCs), helpful in cases of bone stock alteration, are usually used in association with a reinforcement device. To simplify the intervention in elderly subjects or those with a poor bone stock, the cups can be cemented directly into the bone, but the long-term result remains uncertain. We conducted a retrospective study in this population so as to: (1) assess whether cemented fixation of a DMC without a reinforcement device leads to a higher loosening rate, (2) confirm its efficacy in preventing dislocations in subjects at high risk of instability, and (3) measure the functional results. Cemented fixation of a DMC is reliable in cases of moderate alteration of bone stock. Sixty-four patients (66 hips) undergoing implantation of a cemented DMC (Saturne™) without a reinforcement device were included in this single-center retrospective study. Their mean age was 79.8 years (range, 40-95 years). The indications varied: hip osteoarthritis (30.3%), prosthesis revision (44.0%), and trauma (25.8%). The patients were evaluated radiologically and clinically at follow-up. The main evaluation criterion was the revision rate for aseptic loosening. Dislocations, the infection rate, and the Postel Merle d'Aubigné (PMA) score were noted. At the mean follow-up of 4.2 years, three (4.6%) patients had been lost to follow-up and 22 (33.3%) had died. There was one case of aseptic loosening (1.5%). Cup survival was 98% at 5 years (95%CI [94-100]). There were no dislocations. There was one revision for infection. The mean PMA score was 15.5 (range, 9-18). The frequency of acetabular loosening was comparable to the frequency in cemented DMCs with a reinforcement device. A cemented DMC without a reinforcement device is possible and is a simple and viable option when there is moderate bone stock alteration. IV, retrospective cohort study. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
The Transverse Acetabular Ligament as an Intraoperative Guide to Cup Abduction.
Hiddema, Willem B; van der Merwe, Johan F; van der Merwe, Werner
2016-07-01
The success of a total hip arthroplasty relies on optimal acetabular cup placement to ensure mating of the femoral head and acetabular cup throughout all positions of the hip joint. Poor cup placement is associated with dislocation, impingement, microseparation, component loosening, and accelerated wear due to rim loading. This study examined a novel method of using the transverse acetabular ligament (TAL) to guide cup inclination during primary total hip arthroplasty. A descriptive study using 16 hips from 9 cadavers. A computer navigation system measured inclination and version of the acetabular component in 3 positions with the lower edge of cup: (1) flush with, (2) 5 mm proximal to, and (3) 5 mm distal to free border of the TAL. The median inclination angles were 44° in position (1), 30° in position (2), and 64° in position (3). The median anteversion angle for all positions was 19°. Cup inclination was acceptable when the lower edge of the cup was flush or within 5 mm proximal to the TAL. Copyright © 2016 Elsevier Inc. All rights reserved.
Experimentally induced cam impingement in the sheep hip.
Siebenrock, Klaus A; Fiechter, Ruth; Tannast, Moritz; Mamisch, Tallal C; von Rechenberg, Brigitte
2013-04-01
Sheep hips have a natural non-spherical femoral head similar to a cam-type deformity in human beings. By performing an intertrochanteric varus osteotomy, cam-type femoro-acetabular impingement (FAI) during flexion can be created. We tested the hypotheses that macroscopic lesions of the articular cartilage and an increased Mankin score (MS) can be reproduced by an experimentally induced cam-type FAI in this ovine in vivo model. Furthermore, we hypothesized that the MS increases with longer ambulatory periods. Sixteen sheep underwent unilateral intertrochanteric varus osteotomy of the hip with the non-operated hip as a control. Four sheep were sacrificed after 14, 22, 30, and 38-weeks postoperatively. We evaluated macroscopic chondrolabral alterations, and recorded the MS, based on histochemical staining, for each ambulatory period. A significantly higher prevalence of macroscopic chondrolabral lesions was found in the impingement zone of the operated hips. The MS was significantly higher in the acetabular/femoral cartilage of the operated hips. Furthermore, these scores increased as the length of the ambulatory period increased. Cam-type FAI can be induced in an ovine in vivo model. Localized chondrolabral degeneration of the hip, similar to that seen in humans (Tannast et al., Clin Orthop Relat Res 2008; 466: 273-280; Beck et al., J Bone Joint Surg Br 2005; 87: 1012-1018), can be reproduced. This experimental sheep model can be used to study cam-type FAI. Copyright © 2012 Orthopaedic Research Society.
Verlinden, Vincentius J A; de Kruijf, Marjolein; Bierma-Zeinstra, Sita M A; Hofman, Albert; Uitterlinden, André G; Ikram, M Arfan; van Meurs, Joyce B J; van der Geest, Jos N
2017-05-01
Hip and knee osteoarthritis (OA) are debilitating diseases that impair gait at severe stages. Although associations between OA and gait are established for normal walking, little is known about its relation with turning and tandem (heel-to-toe) walking. Furthermore, it is unknown how asymptomatic OA associates with gait, and whether associations differ by sex. We investigated how symptomatic and asymptomatic hip and knee OA associate with gait in community-dwelling individuals. In 2706 participants of a population-based cohort study, gait was assessed by electronic walkway and summarised into seven gait domains. Hip and knee radiographs were graded for radiographic OA (ROA) using the Kellgren and Lawrence (K&L) score. Linear regression was used to investigate associations between ROA and gait. Analyses were repeated including only participants with asymptomatic ROA, defined as a K&L-score of 2 without pain. In total, 177 participants (6.5%) had hip ROA and 441 (16.3%) knee ROA. We found no associations of knee ROA with gait. Hip ROA associated with Rhythm, Tandem, and Turning. Furthermore, unilateral hip ROA associated with larger gait asymmetry and gait differences in osteoarthritic and non-osteoarthritic leg, when compared to people without hip ROA. Associations between hip ROA and gait were generally stronger for women than men. Associations for hip ROA remained after restricting to asymptomatic ROA. Hip ROA, but not knee ROA, associates with gait differences in normal walking, turning, and tandem walking in community-dwelling individuals. These associations differ between the sexes, and are already present for asymptomatic ROA. Copyright © 2017 Elsevier B.V. All rights reserved.
Effects of imbalanced muscle loading on hip joint development and maturation.
Ford, Caleb A; Nowlan, Niamh C; Thomopoulos, Stavros; Killian, Megan L
2017-05-01
The mechanical loading environment influences the development and maturation of joints. In this study, the influence of imbalanced muscular loading on joint development was studied using localized chemical denervation of hip stabilizing muscle groups in neonatal mice. It was hypothesized that imbalanced muscle loading, targeting either gluteal muscles or quadriceps muscles, would lead to bilateral hip joint asymmetry, as measured by acetabular coverage, femoral head volume and bone morphometry, and femoral-acetabular shape. The contralateral hip joints as well as age-matched, uninjected mice were used as controls. Altered bone development was analyzed using micro-computed tomography, histology, and image registration techniques at postnatal days (P) 28, 56, and 120. This study found that unilateral muscle unloading led to reduced acetabular coverage of the femoral head, lower total volume, lower bone volume ratio, and lower mineral density, at all three time points. Histologically, the femoral head was smaller in unloaded hips, with thinner triradiate cartilage at P28 and thinner cortical bone at P120 compared to contralateral hips. Morphological shape changes were evident in unloaded hips at P56. Unloaded hips had lower trabecular thickness and increased trabecular spacing of the femoral head compared to contralateral hips. The present study suggests that decreased muscle loading of the hip leads to altered bone and joint shape and growth during postnatal maturation. Statement of Clinical Significance: Adaptations from altered muscle loading during postnatal growth investigated in this study have implications on developmental hip disorders that result from asymmetric loading, such as patients with limb-length inequality or dysplasia. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1128-1136, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Transfusions and blood loss in total hip and knee arthroplasty: a prospective observational study.
Carling, Malin S; Jeppsson, Anders; Eriksson, Bengt I; Brisby, Helena
2015-03-28
There is a high prevalence of blood product transfusions in orthopedic surgery. The reported prevalence of red blood cell transfusions in unselected patients undergoing hip or knee replacement varies between 21% and 70%. We determined current blood loss and transfusion prevalence in total hip and knee arthroplasty when tranexamic acid was used as a routine prophylaxis, and further investigated potential predictors for excessive blood loss and transfusion requirement. In total, 193 consecutive patients undergoing unilateral hip (n = 114) or knee arthroplasty (n = 79) were included in a prospective observational study. Estimated perioperative blood loss was calculated and transfusions of allogeneic blood products registered and related to patient characteristics and perioperative variables. Overall transfusion rate was 16% (18% in hip patients and 11% in knee patients, p = 0.19). Median estimated blood loss was significantly higher in hip patients (984 vs 789 mL, p < 0.001). Preoperative hemoglobin concentration was the only independent predictor of red blood cell transfusion in hip patients while low hemoglobin concentration, body mass index, and operation time were independent predictors for red blood cell transfusion in knee patients. The prevalence of red blood cell transfusion was lower than previously reported in unselected total hip or knee arthroplasty patients. Routine use of tranexamic acid may have contributed. Low preoperative hemoglobin levels, low body mass index, and long operation increase the risk for red blood cell transfusion.
Test-Retest Reliability of Innovated Strength Tests for Hip Muscles
Meyer, Christophe; Corten, Kristoff; Wesseling, Mariska; Peers, Koen; Simon, Jean-Pierre; Jonkers, Ilse; Desloovere, Kaat
2013-01-01
The burden of hip muscles weakness and its relation to other impairments has been well documented. It is therefore a pre-requisite to have a reliable method for clinical assessment of hip muscles function allowing the design and implementation of a proper strengthening program. Motor-driven dynamometry has been widely accepted as the gold-standard for lower limb muscle strength assessment but is mainly related to the knee joint. Studies focusing on the hip joint are less exhaustive and somewhat discrepant with regard to optimal participants position, consequently influencing outcome measures. Thus, we aimed to develop a standardized test setup for the assessment of hip muscles strength, i.e. flexors/extensors and abductors/adductors, with improved participant stability and to define its psychometric characteristics. Eighteen participants performed unilateral isokinetic and isometric contractions of the hip muscles in the sagittal and coronal plane at two separate occasions. Peak torque and normalized peak torque were measured for each contraction. Relative and absolute measures of reliability were calculated using the intraclass correlation coefficient and standard error of measurement, respectively. Results from this study revealed higher levels of between-day reliability of isokinetic/isometric hip abduction/flexion peak torque compared to existing literature. The least reliable measures were found for hip extension and adduction, which could be explained by a less efficient stabilization technique. Our study additionally provided a first set of reference normalized data which can be used in future research. PMID:24260550
Guillain-Barré Syndrome presenting as unilateral hip pain in a child.
Neocleous, Charalambos; Diakolios, Konstandinos; Adramerina, Alkistis; Varveris, Evangelos; Tsioni, Vasiliki; Machairidou, Konstandina
2015-01-01
The aim of this report is to highlight the importance of close observation and follow-up in children who present with an acutely irritable hip. This is because hip pain is a symptom of not only benign but also severe conditions. Thus, at the time of the initial presentation, hip pain can be misdiagnosed. This report serves as an example for a wide range of doctors such as orthopaedic surgeons, paediatricians, emergency room physicians or primary care physicians, because these are the first-line doctors who treat patients with a painful hip. We herein present a three-year-old child who was admitted to our hospital with pain in the right leg and initially diagnosed with transient synovitis of the hip. An additional examination two days later, after severe deterioration of the clinical picture, revealed that our patient was actually suffering from Guillain-Barré syndrome. Failure to diagnose Guillain-Barré syndrome and initiating prompt treatment is potentially life-threatening. Clinicians should be aware that hip pain could be the presenting complaint of Guillain-Barré syndrome, a syndrome that has many clinical features. Even when all the clinical and laboratory findings indicate a benign condition, Guillain- Barré syndrome should still be considered. Therefore, close observation and follow-up in children who present with an acutely irritable hip is highly recommended. In this way, the potentially catastrophic consequences of more severe conditions can be avoided. Copyright © 2015 by Academy of Sciences and Arts of Bosnia and Herzegovina.
Interventions for Hip Pain in the Maturing Athlete
Gomberawalla, M. Mustafa; Kelly, Bryan T.; Bedi, Asheesh
2014-01-01
Context: Femoroacetabular impingement (FAI) alters hip mechanics, results in hip pain, and may lead to secondary osteoarthritis (OA) in the maturing athlete. Hip impingement can be caused by osseous abnormalities in the proximal femur or acetabulum. These impingement lesions may cause altered loads within the hip joint, which result in repetitive collision damage or sheer forces to the chondral surfaces and acetabular labrum. These anatomic lesions and resultant abnormal mechanics may lead to early osteoarthritic changes. Evidence Acquisition: Relevant articles from the years 1995 to 2013 were identified using MEDLINE, EMBASE, and the bibliographies of reviewed publications. Level of Evidence: Level 4. Results: Improvements in hip arthroscopy have allowed FAI to be addressed utilizing the arthroscope. Adequately resecting the underlying osseous abnormalities is essential to improving hip symptomatology and preventing further chondral damage. Additionally, preserving the labrum by repairing the damaged tissue and restoring the suction seal may theoretically help normalize hip mechanics and prevent further arthritic changes. The outcomes of joint-preserving treatment options may be varied in the maturing athlete due to the degree of underlying OA. Irreversible damage to the hip joint may have already occurred in patients with moderate to advanced OA. In the presence of preexisting arthritis, these patients may only experience fair or even poor results after hip arthroscopy, with early conversion to hip replacement. For patients with advanced hip arthritis, total hip arthroplasty remains a treatment option to reliably improve symptoms with good to excellent outcomes and return to low-impact activities. Conclusion: Advances in the knowledge base and treatment techniques of intra-articular hip pain have allowed surgeons to address this complex clinical problem with promising outcomes. Traditionally, open surgical dislocations for hip preservation surgery have shown good long-term results. Improvements in hip arthroscopy have led to outcomes equivalent to open surgery while utilizing significantly less invasive techniques. However, outcomes may ultimately depend on the degree of underlying OA. When counseling the mature athlete with hip pain, an understanding of the underlying anatomy, degree of arthritis, and expectations will help guide the treating surgeon in offering appropriate treatment options. PMID:24427445
Kim, Y-H
2008-03-01
This study reviewed the results of a cementless anatomical femoral component to give immediate post-operative stability, and with a narrow distal section in order not to contact the femoral cortex in the diaphysis, ensuring exclusively metaphyseal loading. A total of 471 patients (601 hips) who had a total hip replacement between March 1995 and February 2002 were included in the study. There were 297 men and 174 women. The mean age at the time of operation was 52.7 years (28 to 63). Clinical and radiological evaluation were performed at each follow-up. Bone densitometry was carried out on all patients two weeks after operation and at the final follow-up examination. The mean follow-up was 8.8 years (5 to 12). The mean pre-operative Harris hip score was 41 points (16 to 54), which improved to a mean of 96 (68 to 100) at the final follow-up. No patient complained of thigh pain at any stage. No acetabular or femoral osteolysis was observed and no hip required revision for aseptic loosening of either component. Deep infection occurred in two hips (0.3%) which required revision. One hip (0.2%) required revision of the acetabular component for recurrent dislocation. Bone mineral densitometry revealed a minimal bone loss in the proximal femur. This cementless anatomical femoral component with metaphyseal loading but without distal fixation produced satisfactory fixation and encourages proximal femoral loading.
Salmingo, Remel Alingalan; Skytte, Tina Lercke; Traberg, Marie Sand; Mikkelsen, Lars Pilgaard; Henneberg, Kaj-Åge; Wong, Christian
2017-01-01
Perthes' disease is a destructive hip joint disorder characterized by malformation of the femoral head in young children. While the morphological changes have been widely studied, the biomechanical effects of these changes still need to be further elucidated. The objective of this study was to develop a method to investigate the biomechanical alterations in Perthes' disease by finite element (FE) contact modeling using MRI. The MRI data of a unilateral Perthes' case was obtained to develop the three-dimensional FE model of the hip joint. The stress and contact pressure patterns in the unaffected hip were well distributed. Elevated concentrations of stress and contact pressure were found in the Perthes' hip. The highest femoral cartilage von Mises stress 3.9 MPa and contact pressure 5.3 MPa were found in the Perthes' hip, whereas 2.4 MPa and 4.9 MPa in the healthy hip, respectively. The healthy bone in the femoral head of the Perthes' hip carries additional loads as indicated by the increase of stress levels around the necrotic-healthy bone interface. Identifying the biomechanical changes, such as the location of stress and contact pressure concentrations, is a prerequisite for the preoperative planning to obtain stress relief for the highly stressed areas in the malformed hip. This single-patient study demonstrated that the biomechanical alterations in Perthes' disease can be evaluated individually by patient-specific finite element contact modeling using MRI. A multi-patient study is required to test the strength of the proposed method as a pre-surgery planning tool.
Doherty, Cailbhe; Bleakley, Chris; Hertel, Jay; Caulfield, Brian; Ryan, John; Sweeney, Kevin; Delahunt, Eamonn
2015-02-01
Longitudinal analyses of participants with a history of lateral ankle sprain are lacking. This investigation combined measures of inter-joint coordination and stabilometry to evaluate eyes-open (condition 1) and eyes-closed (condition 2) static unilateral stance performance in a group of participants, 6-months after they sustained an acute, first-time lateral ankle sprain in comparison to a control group. Sixty-nine participants with a 6-month history of first-time lateral ankle sprain and 20 non-injured controls completed three 20-second unilateral stance task trials in conditions 1 and 2. An adjusted coefficient of multiple determination statistic was used to compare stance limb 3-dimensional kinematic data for similarity in the aim of establishing patterns of lower-limb inter-joint coordination. The fractal dimension of the stance limb centre of pressure path was also calculated. Between-group analyses revealed significant differences in stance limb inter-joint coordination strategies for conditions 1 and 2, and in the fractal dimension of the centre-of-pressure path for condition 2 only. Injured participants displayed increases in ankle-hip linked coordination compared to controls in condition 1 (sagittal/frontal plane: 0.15 [0.14] vs 0.06 [0.04]; η(2)=.19; sagittal/transverse plane: 0.14 [0.11] vs 0.09 [0.05]; η(2)=0.14) and condition 2 (sagittal/frontal plane: 0.15 [0.12] vs 0.08 [0.06]; η(2)=0.23), with an associated decrease in the fractal dimension of the centre-of-pressure path (injured limb: 1.23 [0.13] vs 1.36 [0.13]; η(2)=0.20). Participants with a 6-month history of first-time lateral ankle sprain exhibit a hip-dominant coordination strategy for static unilateral stance compared to non-injured controls. Copyright © 2014 Elsevier Ltd. All rights reserved.
Guyen, Olivier; Lewallen, David G; Cabanela, Miguel E
2008-07-01
The Osteonics constrained tripolar implant has been one of the most commonly used options to manage recurrent instability after total hip arthroplasty. Mechanical failures were expected and have been reported. The purpose of this retrospective review was to identify the observed modes of failure of this device. Forty-three failed Osteonics constrained tripolar implants were revised at our institution between September 1997 and April 2005. All revisions related to the constrained acetabular component only were considered as failures. All of the devices had been inserted for recurrent or intraoperative instability during revision procedures. Seven different methods of implantation were used. Operative reports and radiographs were reviewed to identify the modes of failure. The average time to failure of the forty-three implants was 28.4 months. A total of five modes of failure were observed: failure at the bone-implant interface (type I), which occurred in eleven hips; failure at the mechanisms holding the constrained liner to the metal shell (type II), in six hips; failure of the retaining mechanism of the bipolar component (type III), in ten hips; dislocation of the prosthetic head at the inner bearing of the bipolar component (type IV), in three hips; and infection (type V), in twelve hips. The mode of failure remained unknown in one hip that had been revised at another institution. The Osteonics constrained tripolar total hip arthroplasty implant is a complex device involving many parts. We showed that failure of this device can occur at most of its interfaces. It would therefore appear logical to limit its application to salvage situations.
Xu, Jiawei; Xu, Chen; Mao, Yuanqing; Zhang, Jincheng; Li, Huiwu; Zhu, Zhenan
2016-06-01
We sought to evaluate posterosuperior placement of the acetabular component at the true acetabulum during acetabular reconstruction in patients with Crowe type-IV developmental dysplasia of the hip. Using pelvic computed tomography and image processing, we developed a two-dimensional mapping technique to demonstrate the distribution of preoperative three-dimensional cup coverage at the true acetabulum, determined the postoperative location of the acetabular cup, and calculated postoperative three-dimensional coverage for 16 Crowe type-IV dysplastic hips in 14 patients with a mean age of 52 years (33-78 years) who underwent total hip arthroplasty. Mean follow-up was 6.3 years (5.5-7.3 years). On preoperative mapping, the maximum three-dimensional coverage using a 44-mm cup was 87.31% (77.36%-98.14%). Mapping enabled the successful replacement of 16 hips using a mean cup size of 44.13 mm (42-46 mm) with posterosuperior placement of the cup. Early weight-bearing and no prosthesis revision or loosening during follow-up were achieved in all patients. The postoperative two-dimensional coverage on anteroposterior radiographs and three-dimensional coverage were 96.15% (89.49%-100%) and 83.42% (71.81%-98.50%), respectively. This technique may improve long-term implant survival in patients with Crowe-IV developmental dysplasia of the hip undergoing total hip arthroplasty by allowing the use of durable bearings, increasing host bone coverage, ensuring initial stability, and restoring the normal hip center. Copyright © 2015 Elsevier Inc. All rights reserved.
Anwander, Helen; Siebenrock, Klaus A; Tannast, Moritz; Steppacher, Simon D
2017-04-01
Since the importance of an intact labrum for normal hip function has been shown, labral reattachment has become the standard method for open or arthroscopic treatment of hips with femoroacetabular impingement (FAI). However, no long-term clinical results exist evaluating the effect of labral reattachment. A 2-year followup comparing open surgical treatment of FAI with labral resection versus reattachment was previously performed at our clinic. The goal of this study was to report a concise followup of these patients at a minimum of 10 years. We asked if patients undergoing surgical hip dislocation for the treatment of mixed-type FAI with labral reattachment compared with labral resection had (1) improved hip pain and function based on the Merle d'Aubigné-Postel score; and (2) improved survival at 10-year followup. Between June 1999 and July 2002, we performed surgical hip dislocation with femoral neck osteoplasty and acetabular rim trimming in 52 patients (60 hips) with mixed-type FAI. In the first 20 patients (25 hips) until June 2001, a torn labrum or a detached labrum in the area of acetabular rim resection was resected. In the next 32 patients (35 hips), reattachment of the labrum was performed. The same indications were used to perform both procedures during the periods in question. Of the 20 patients (25 hips) in the first group, 19 patients (95%) (24 hips [96%]) were available for clinical and/or radiographic followup at a minimum of 10 years (mean, 13 years; range, 12-14 years). Of the 32 patients (35 hips) in the second group, 29 patients (91%) (32 hips [91%]) were available for clinical and/or radiographic followup at a minimum of 10 years (mean, 12 years; range, 10-13 years). We used the anterior impingement test to assess pain. Function was assessed using the Merle d'Aubigné- Postel score and ROM. Survivorship calculation was performed using the method of Kaplan-Meier with failure defined as conversion to THA, progression of osteoarthritis (of one grade or more on the Tönnis score), and a Merle d'Aubigné-Postel score < 15. At the 10-year followup, hip pain in hips with labral reattachment was slightly improved for the postoperative Merle d'Aubigné-Postel pain subscore (5.0 ± 1.0 [3-6] versus 3.9 ± 1.7 [0-6]; p = 0.017). No difference existed for the prevalence of hip pain assessed using the anterior impingement test with the numbers available (resection group 52% [11 of 21 hips] versus reattachment group 27% [eight of 30 hips]; odds ratio, 3.03; 95% confidence interval [CI], 0.93-9.83; p = 0.062). Function was slightly better in the reattachment group for the overall Merle d'Aubigné-Postel score (16.7 ± 1.5 [13-18] versus 15.3 ± 2.4 [9-18]; p = 0.028) and hip abduction (45° ± 13° [range, 30°-70°] versus 38° ± 8° [range, 25°-45°]; p = 0.001). Hips with labral reattachment showed a better survival rate at 10 years than did hips that underwent labral resection (78%; 95% CI, 64%-92% versus 46%, 95% CI, 26%-66%; p = 0.009) with the endpoints defined as conversion to THA, progression of osteoarthritis, and a Merle d'Aubigné-Postel score < 15. With isolated endpoints, survival at 10 years was increased for labral reattachment and the endpoint Merle d'Aubigné score < 15 (83%, 95% CI, 70%-97% versus 48%, 95% CI, 28%-69%; p = 0.009) but did not differ for progression of osteoarthritis (83%, 95% CI, 68%-97% versus 81%, 95% CI, 63%-98%; p = 0.957) or conversion to THA (94%, 95% CI, 86%-100% versus 87%, 95% CI, 74%-100%; p = 0.366). The current results suggest the importance of preserving the labrum and show that resection may put the hip at risk for early deterioration. At 10-year followup, hips with labral reattachment less frequently had a decreased Merle d'Aubigné score but no effect on progression of osteoarthritis or conversion to THA could be shown. Level III, therapeutic study.
Decline eccentric squats increases patellar tendon loading compared to standard eccentric squats.
Kongsgaard, M; Aagaard, P; Roikjaer, S; Olsen, D; Jensen, M; Langberg, H; Magnusson, S P
2006-08-01
Recent studies have shown excellent clinical results using eccentric squat training on a 25 degrees decline board to treat patellar tendinopathy. It remains unknown why therapeutic management of patellar tendinopathy using decline eccentric squats offer superior clinical efficacy compared to standard horizontal eccentric squats. This study aimed to compare electromyography activity, patellar tendon strain and joint angle kinematics during standard and decline eccentric squats. Thirteen subjects performed unilateral eccentric squats on flat-and a 25 degrees decline surface. During the squats, electromyography activity was obtained in eight representative muscles. Also, ankle, knee and hip joint goniometry was obtained. Additionally, patellar tendon strain was measured in vivo using ultrasonography as subjects maintained a unilateral isometric 90 degrees knee angle squat position on either flat or 25 degrees decline surface. Patellar tendon strain was significantly greater (P<0.05) during the squat position on the decline surface compared to the standard surface. The stop angles of the ankle and hip joints were significantly smaller during the decline compared to the standard squats (P<0.001, P<0.05). Normalized mean electromyography amplitudes of the knee extensor muscles were significantly greater during the decline compared to the standard squats (P<0.05). Hamstring and calf muscle mean electromyography did not differ, respectively, between standard and decline squats. The use of a 25 degrees decline board increases the load and the strain of the patellar tendon during unilateral eccentric squats. This finding likely explains previous reports of superior clinical efficacy of decline eccentric squats in the rehabilitative management of patellar tendinopathy.
The jumbo acetabular component for acetabular revision: Curtain Calls and Caveats.
Lachiewicz, P F; Watters, T S
2016-01-01
The 'jumbo' acetabular component is now commonly used in acetabular revision surgery where there is extensive bone loss. It offers high surface contact, permits weight bearing over a large area of the pelvis, the need for bone grafting is reduced and it is usually possible to restore centre of rotation of the hip. Disadvantages of its use include a technique in which bone structure may not be restored, a risk of excessive posterior bone loss during reaming, an obligation to employ screw fixation, limited bone ingrowth with late failure and high hip centre, leading to increased risk of dislocation. Contraindications include unaddressed pelvic dissociation, inability to implant the component with a rim fit, and an inability to achieve screw fixation. Use in acetabulae with < 50% bone stock has also been questioned. Published results have been encouraging in the first decade, with late failures predominantly because of polyethylene wear and aseptic loosening. Dislocation is the most common complication of jumbo acetabular revisions, with an incidence of approximately 10%, and often mandates revision. Based on published results, a hemispherical component with an enhanced porous coating, highly cross-linked polyethylene, and a large femoral head appears to represent the optimum tribology for jumbo acetabular revisions. ©2016 The British Editorial Society of Bone & Joint Surgery.
[Acetabuloplasty in cerebral palsy patients].
Schejbalová, A; Chládek, P
2007-12-01
Acetabuloplasty as an isolated surgical procedure is one of the options allowing for hip joint realignment in cerebral palsy patients. Also, it is often involved in combined techniques used for hip joint reconstruction. In the years 2004-2005, 20 cerebral palsy patients, aged from 4 to 13 years, were indicated for acetabuloplasty. The group included children with varying degrees of locomotor disability, ranging from inability even to crawl to ability to move without support (stages 2 to 7 on the Vojta scale). Clinical and X-ray findings were evaluated at 2 and 6 months after surgical treatment and then every 6 months of follow- up. The X-ray finding was described by means of CE angle (Wiberg) values and hip migration percentage. Of 21 hips (in 20 patients) treated by acetabuloplasty in our modification during the two years, one developed recurrent dorsal dislocation which was possible to deal with by conservative treatment. All hips pre-operatively categorized as group B or group C were post-operatively assessed as group A hips. Subsequent migration of the acetabulum occurred within a year in two patients with distinct original asymmetry. Surgery on bones comprising the hip joint in cerebral palsy patients is indicated according to the degree of lateral migration and changes in hip joint geometry involving the proximal femur or pelvis, or in combination with open reduction. Acetabuloplasty is indicated as an isolated procedure or as part of combined techniques leading to a better coverage of the hip joint. It is recommended for children up to 10 years of age, but also older ones, in whom the flexibility of child bones enables us to do without internal osteosynthesis. Acetabuloplasty is indicated as an isolated surgical procedure for hip joint subluxation in cerebral palsy children. It has no adverse effects on hip abductors that, in cerebral palsy patients, are 85 % insufficient. It improves hip joint symmetry and helps to avoid more demanding reconstructive or palliative procedures. Key words: cerebral palsy, acetabuloplasty, lateral migration.
Short-term clinical experience with hip resurfacing arthroplasty.
Cieliński, Łukasz; Kusz, Damian; Wojciechowski, Piotr; Dziuba, Anna
2007-01-01
This paper discusses the authors' experience with hip resurfacing arthroplasty. Although introduced many years ago, the method did not gain wide popularity because of poor long-term outcomes. At present, owing to the introduction of metal-on-metal bearings and hybrid fixation techniques, short- and mid-term results are very good and encourage wider use of this technique, especially in the younger and more active patients whose results with standard total hip replacements would be unsatisfactory. We performed 13 hip resurfacing arthroplasties at our institution between August 1, 2005, and May 1, 2006. Twelve patients reported for the scheduled follow-up and were included in the study. Treatment outcomes were assessed according to the Harris Hip Score. The short-term outcomes of hip resurfacing arthroplasties are encouraging. In the study group there were no intraoperative complications, infections, peripheral nerve palsy, hip dislocations or clinically overt vein thrombosis. All of the patients reported complete or major pain relief. Clinical assessment according to the Harris Hip Score revealed improvement from an average of 57.7 (20.1) points preoperatively to an average of 87.7 (12) points after the surgery. Crutches were used for a maximum of 6 weeks postoperatively. All of the patients are currently able to walk without crutches with full weight-bearing. 1) Hip resurfacing arthroplasty seems to be an advisable method of operative management of younger, active patients, in whom standard THR would be associated with a high risk of failure; it allows THR to be postponed and carried out as a revision surgery with the acetabular component already in place. 2) Despite the good short- and mid-term results, the utility of this method should be evaluated with caution due to the lack of adequate long-term follow-up data.
Paleoepidemiolgical patterns of trauma in a prehistoric population from central California.
Jurmain, R
2001-05-01
Skeletal trauma was investigated in a large collection of human remains from central California (N = 162 aged and sexed adults). Lesions investigated included cranial and long bone fractures, projectile wounds, and dislocation. Long bone fractures were found in 10.5% of individuals; overall, incidence by element was 2.3%. In addition, cranial injuries were found in 4.4% of complete adult crania. Projectile wounds were seen unambiguously in four individuals (with embedded obsidian fragments) and strongly suggested in two other individuals with partially healed lesions. Finally, one case of traumatic hip dislocation was also observed. In both incidence and patterning of injuries, this population is similar to other archeological groups from California. This evidence further supports earlier reports indicating that interpersonal aggression was quite common in prehistoric California.
Hip resurfacing: a large, US single-surgeon series.
Brooks, P J
2016-01-01
Hip resurfacing has been proposed as an alternative to traditional total hip arthroplasty in young, active patients. Much has been learned following the introduction of metal-on-metal resurfacing devices in the 1990s. The triad of a well-designed device, implanted accurately, in the correct patient has never been more critical than with these implants. Following Food and Drug Administration approval in 2006, we studied the safety and effectiveness of one hip resurfacing device (Birmingham Hip Resurfacing) at our hospital in a large, single-surgeon series. We report our early to mid-term results in 1333 cases followed for a mean of 4.3 years (2 to 5.7) using a prospective, observational registry. The mean patient age was 53.1 years (12 to 84); 70% were male and 91% had osteoarthritis. Complications were few, including no dislocations, no femoral component loosening, two femoral neck fractures (0.15%), one socket loosening (0.08%), three deep infections (0.23%), and three cases of metallosis (0.23%). There were no destructive pseudotumours. Overall survivorship at up to 5.7 years was 99.2%. Aseptic survivorship in males under the age of 50 was 100%. We believe this is the largest United States series of a single surgeon using a single resurfacing system. ©2016 The British Editorial Society of Bone & Joint Surgery.
Hip Joint Replacement Using Monofilament Polypropylene Surgical Mesh: An Animal Model
Białecki, Jacek; Klimowicz-Bodys, Małgorzata Dorota; Wierzchoś, Edward; Kołomecki, Krzysztof
2014-01-01
Hip joint dysplasia is a deformation of the articular elements (pelvic acetabulum, head of the femur, and/or ligament of the head of the femur) leading to laxity of the hip components and dislocation of the femoral head from the pelvic acetabulum. Diagnosis is based on symptoms observed during clinical and radiological examinations. There are two treatment options: conservative and surgical. The classic surgical procedures are juvenile pubic symphysiodesis (JPS), triple pelvic osteotomy (TPO), total hip replacement (THR), and femoral head and neck resection (FHNE). The aim of this experiment was to present an original technique of filling the acetabulum with a polypropylene implant, resting the femoral neck directly on the mesh. The experiment was performed on eight sheep. The clinical value of the new surgical technique was evaluated using clinical, radiological, and histological methods. This technique helps decrease the loss of limb length by supporting the femoral neck on the mesh equivalent to the femoral head. It also reduces joint pain and leads to the formation of stable and mobile pseudarthrosis. The mesh manifested osteoprotective properties and enabled the formation of a stiff-elastic connection within the hip joint. The method is very cost-effective and the technique itself is simple to perform. PMID:24987672
Single-stage revision for fungal peri-prosthetic joint infection: a single-centre experience.
Klatte, T O; Kendoff, D; Kamath, A F; Jonen, V; Rueger, J M; Frommelt, L; Gebauer, M; Gehrke, T
2014-04-01
Fungal peri-prosthetic infections of the knee and hip are rare but likely to result in devastating complications. In this study we evaluated the results of their management using a single-stage exchange technique. Between 2001 and 2011, 14 patients (ten hips, four knees) were treated for a peri-prosthetic fungal infection. One patient was excluded because revision surgery was not possible owing to a large acetabular defect. One patient developed a further infection two months post-operatively and was excluded from the analysis. Two patients died of unrelated causes. After a mean of seven years (3 to 11) a total of ten patients were available for follow-up. One patient, undergoing revision replacement of the hip, had a post-operative dislocation. Another patient, undergoing revision replacement of the knee, developed a wound infection and required revision 29 months post-operatively following a peri-prosthetic femoral fracture. The mean Harris hip score increased to 74 points (63 to 84; p < 0.02) in those undergoing revision replacement of the hip, and the mean Hospital for Special Surgery knee score increased to 75 points (70 to 80; p < 0.01) in those undergoing revision replacement of the knee. A single-stage revision following fungal peri-prosthetic infection is feasible, with an acceptable rate of a satisfactory outcome.
Gaida, J; Cook, J; Bass, S; Austen, S; Kiss, Z
2004-01-01
Background: Overuse injury to the patellar tendon (patellar tendinopathy) is a major reason for interrupted training and competition for elite athletes. In both sexes, the prevalence of unilateral and bilateral tendinopathy has been shown to differ. It has been proposed that bilateral pathology may have a different aetiology from unilateral pathology. Investigation of risk factors that may be unique to unilateral and bilateral patellar tendinopathy in female athletes may reveal insights into the aetiology of this condition. Objectives: To examine whether anthropometry, body composition, or muscle strength distinguished elite female basketball players with unilateral or bilateral patellar tendinopathy. Methods: Body composition, anthropometry, and muscle strength were compared in elite female basketball players with unilateral (n = 8), bilateral (n = 7), or no (n = 24) patellar tendinopathy. Body composition was analysed using a dual energy x ray absorptiometer. Anthropometric measures were assessed using standard techniques. Knee extensor strength was measured at 180°/s using an isokinetic dynamometer. z scores were calculated for the unilateral and bilateral groups (using the no tendinopathy group as controls). z scores were tested against zero. Results: The tibia length to stature ratio was approximately 1.3 (1.3) SDs above zero in both the affected and non-affected legs in the unilateral group (p<0.05). The waist to hip ratio was 0.66 (0.78) SD above zero in the unilateral group (p<0.05). In the unilateral group, leg lean to total lean ratio was 0.42 (0.55) SD above zero (p<0.07), the trunk lean to total lean ratio was 0.63 (0.68) SD below zero (p<0.05), and leg fat relative to total fat was 0.47 (0.65) SD below zero (p<0.09). In the unilateral group, the leg with pathology was 0.78 (1.03) SD weaker during eccentric contractions (p<0.07). Conclusions: Unilateral patellar tendinopathy has identifiable risk factors whereas bilateral patellar tendinopathy may not. This suggests that the aetiology of these conditions may be different. However, interpretation must respect the limitation of small subject numbers. PMID:15388543
Khanna, Vickas; Harris, Adam; Farrokhyar, Forough; Choudur, Hema N; Wong, Ivan H
2014-03-01
The purpose of this study was to document and compare the incidence of intra-articular hip pathologic findings identified using arthroscopy versus conventional imaging in patients with acute trauma to the hip. This was a blinded prospective case series study designed to review the incidence of intra-articular pathologic disorders in patients with post-traumatic injury between the ages of 18 and 65 years who were referred to a single surgeon. Injuries included hip dislocation, proximal femur fracture, pelvic ring fracture, acetabular fracture, penetrating injury (gunshot wound), and soft tissue injury. Preoperative radiographs, computed tomographic (CT) scans, or magnetic resonance imaging/magnetic resonance angiography (MRI/MRA) scans (or a combination of these) were obtained. Findings were documented and compared with intraoperative findings. A total of 29 post-traumatic hips were enrolled in this study. Hip arthroscopy identified 17 of 29 hips (59%) as having loose bodies, 11 of 29 (38%) hips as having an intra-articular step deformity, 14 of 29 (49%) hips as having an osteochondral lesion, and 27 of 29 (93%) hips as having a labral tear. Plain radiographs and CT scans yielded low sensitivity when compared with arthroscopy for the identification of loose bodies and step deformities. MRI/MRA comparison with arthroscopic findings suggest that MRI/MRA is an accurate tool for identification of labral tears, because 91% of tears seen on arthroscopy were also identified by MRI/MRA. In 4 hips, however, MRI/MRA failed to identify osteochondral lesions that were subsequently identified by arthroscopy. Traumatic injuries of the hip result in substantial intra-articular pathologic findings, including loose bodies, labral tears, step deformities, and osteochondral lesions. The arthroscope is a powerful tool in identifying these injuries. Plain radiographs and CT scans appear to underestimate the true incidence of loose bodies and step deformities within the joint when compared with hip arthroscopy after a traumatic injury of the hip. Level IV, diagnostic case series. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Tailor-made Surgical Guide Reduces Incidence of Outliers of Cup Placement.
Hananouchi, Takehito; Saito, Masanobu; Koyama, Tsuyoshi; Sugano, Nobuhiko; Yoshikawa, Hideki
2010-04-01
Malalignment of the cup in total hip arthroplasty (THA) increases the risks of postoperative complications such as neck cup impingement, dislocation, and wear. We asked whether a tailor-made surgical guide based on CT images would reduce the incidence of outliers beyond 10 degrees from preoperatively planned alignment of the cup compared with those without the surgical guide. We prospectively followed 38 patients (38 hips, Group 1) having primary THA with the conventional technique and 31 patients (31 hips, Group 2) using the surgical guide. We designed the guide for Group 2 based on CT images and fixed it to the acetabular edge with a Kirschner wire to indicate the planned cup direction. Postoperative CT images showed the guide reduced the number of outliers compared with the conventional method (Group 1, 23.7%; Group 2, 0%). The surgical guide provided more reliable cup insertion compared with conventional techniques. Level II, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
Cobalt toxicity after revision total hip replacement due to fracture of a ceramic head.
Pelayo-de Tomás, J M; Novoa-Parra, C; Gómez-Barbero, P
Symptomatic cobalt toxicity from a failed total hip replacement is a rare, but devastating complication. Potential clinical findings include cardiomyopathy, hypothyroidism, skin rash, visual and hearing impairment, polycythaemia, weakness, fatigue, cognitive impairment, and neuropathy. The case is presented of a 74year-old man in whom, after a ceramic-ceramic replacement and two episodes of prosthetic dislocation, it was decided to replace it with a polyethylene-metal total hip arthroplasty (THA). At 6months after the revision he developed symptoms of cobalt toxicity, confirmed by analytical determination (serum cobalt level=651.2μg/L). After removal of the prosthesis, the levels of chromium and cobalt in blood and urine returned to normal, with the patient currently being asymptomatic. It is recommended to use a new ceramic on ceramic bearing at revision, in order to minimise the risk of wear-related cobalt toxicity following breakage of ceramic components. Copyright © 2016 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.
[Results and experiences of conversion of hip arthrodesis ].
Schuh, A; Zeiler, G; Werber, S
2005-03-01
With the predictably good outcome of total hip arthroplasty today (THA), hip arthrodesis currently has limited indications. Over the long term, however, most patients develop secondary degenerative arthritis in the spine, contralateral hip, and ipsilateral knee due to overloading. The deteriorating condition of these joints eventually causes the onset of pain, which often requires conversion of a fused hip to a THA. The results and experiences of conversions of a hip arthrodesis into a THA are reported. Between 1 January 1985 and 31 December 2001 conversion of a previously performed arthrodesis of the hip to THA was carried out in a total of 45 patients; 34 patients could be followed up after the conversion to THA after a mean of 77.5 months (min.: 24, max.: 208). The primary indications for the conversion were low back pain (n=21) and ipsilateral knee pain (n=13). The mean age at the time of THA was 75.3 years (min.: 32, max.: 74). The mean time interval between the arthrodesis and the conversion to THA was 30.4 years (min.: 5, max.: 66). Of 34 hips, 29 (85%) were either pain free or had minimal pain. Complications included one persisting sciatic nerve palsy, two superficial infections, two periprosthetic fractures, and two heterotopic ossifications IV degrees with one recurrence of ankylosis and one marked reduction of motion. Revision arthroplasty was performed in four hips. Postoperatively 7 patients showed no limping, 11 showed a slight limp, and 17 a pronounced limp. Recurrent dislocations occurred in one patient. We conclude that this operation can lead to satisfactory results even after a long duration of the arthrodesis. There is a high rate of complications after conversion of a hip arthrodesis to a total hip arthroplasty. These issues must be carefully considered and discussed with the patient before any conversion procedure.
[Joint dislocation after total knee arthroplasty as an ankle fracture complication. Case report].
Hrubina, M; Skoták, M
2012-01-01
Joint dislocation after total knee arthroplasty is a rare complication. It is described as the result of ligamentous instability. Here we report the case of an 82-year-old women who underwent primary total knee arthroplasty (TKA) for advanced primary grade III gonarthrosis. At 3 post-operative months the joint was stable and painless, with radiographic evidence of good TKA alignment and integration. At 4 months the patient suffered injury to the ankle involving a bimalleolar fracture and damage to knee soft tissues. The fracture was surgically treated. Subsequently, dorsal tibial dislocation was manifested. This was managed by individual intramedullary nail arthrodesis. At 8 months following the operation, the knee condition was satisfactory, with rigid arthrodesis and leg shortening of 4 cm. The patient was satisfied because she was free of pain and able to walk. Arthrodesis of the knee joint with an individual nail is an option for a definitive treatment of TKA instability. When other joints, such as ankle or hip joints, are injured, it is recommended to pay attention also to any TKA implanted previously because of potential development of instability or infection.
Pain distribution in primary care patients with hip osteoarthritis.
Poulsen, Erik; Overgaard, Søren; Vestergaard, Jacob T; Christensen, Henrik W; Hartvigsen, Jan
2016-12-01
Hip osteoarthritis (OA) is the most common diagnosis in primary care adult patients presenting with hip pain but pain location and pain distribution in primary care patients with hip OA have been reported inadequately. To describe pain location and pain distribution in primary care patients with clinical and radiographic confirmed hip OA. Primary care patients with unilateral clinical and radiographic hip OA living on the island of Funen, Denmark were recruited from primary care to participate in a randomized clinical trial. At baseline, patients recorded pain intensity using an 11-box numeric rating scale and the distribution of hip pain using a manikin displaying three separate views: front, back and lateral. Pain drawings were analysed using a template to determine the most frequent pain locations and distribution of pain. Pain drawings were completed by 109 patients of which 108 (99%) were valid. The mean age of patients was 65 (SD 9) years and 44% were females. The mean pain intensity was 5.4 (SD 2.0). A total of 77% had marked the greater trochanter area, 53% the groin area, 42% the anterior/lateral thigh area, 38% the buttock area, 17% the knee and 15% the lower leg area. No patients marked pain exclusively in the areas of the knee, posterior thigh or lower leg. The most common pain locations of patients with hip OA presenting to primary care are the greater trochanter, groin, thigh and buttock areas. No patients recorded pain exclusively in the knee or lower leg. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Biver, A; De Rijcke, S; Toppet, V; Ledoux-Corbusier, M; Van Maldergem, L
1994-06-01
We present a female infant exhibiting congenital cutis laxa with retardation of growth and motor development, ligamentous laxity and congenital dislocation of the hips. This connective tissue disorder was associated with Dandy-Walker malformation, atrial and ventricular defect and minor bone abnormalities including multiple wormian bones, abnormal tubulation of long bones and absent twelfth pair of ribs. This association is believed to be unique.
Chen, Qingshan; Lazennec, Jean Yves; Guyen, Olivier; Kinbrum, Amy; Berry, Daniel J; An, Kai-Nan
2005-07-01
Tripolar total hip arthroplasty (THA) prosthesis had been suggested as a method to reduce the occurrence of hip dislocation and microseparation. Precisely measuring the motion of the intermediate component in vitro would provide fundamental knowledge for understanding its mechanism. The present study validates the accuracy and repeatability of a three-dimensional motion analysis system to quantitatively measure the relative motion of the intermediate component of tripolar total hip arthroplasty prostheses. Static and dynamic validations of the system were made by comparing the measurement to that of a potentiometer. Differences between the mean system-calculated angle and the angle measured by the potentiometer were within +/-1 degrees . The mean within-trial variability was less than 1 degrees . The mean slope was 0.9-1.02 for different angular velocities. The dynamic noise was within 1 degrees . The system was then applied to measure the relative motion of an eccentric THA prosthesis. The study shows that this motion analysis system provides an accurate and practical method for measuring the relative motion of the tripolar THA prosthesis in vitro, a necessary first step towards the understanding of its in vivo kinematics.
Sports Injuries about the Hip: What the Radiologist Should Know.
Hegazi, Tarek M; Belair, Jeffrey A; McCarthy, Eoghan J; Roedl, Johannes B; Morrison, William B
2016-10-01
Injuries of the hip and surrounding structures represent a complex and commonly encountered scenario in athletes, with improper diagnosis serving as a cause of delayed return to play or progression to a more serious injury. As such, radiologists play an essential role in guiding management of athletic injuries. Familiarity with hip anatomy and the advantages and limitations of various imaging modalities is of paramount importance for accurate and timely diagnosis. Magnetic resonance (MR) imaging is often the modality of choice for evaluating many of the injuries discussed, although preliminary evaluation with conventional radiography and use of other imaging modalities such as ultrasonography (US), computed tomography, and bone scintigraphy may be supplementary or preferred in certain situations. Stress fractures, thigh splints, and posterior hip dislocations are important structural injuries to consider in the athlete, initially imaged with radiographs and often best diagnosed with MR imaging. Apophyseal injuries are particularly important to consider in young athletes and may be acute or related to chronic repetitive microtrauma. Femoroacetabular impingement has been implicated in development of labral tears and cartilage abnormalities. Tear of the ligamentum teres is now recognized as a potential cause of hip pain and instability, best evaluated with MR arthrography. Greater trochanteric pain syndrome encompasses a group of conditions leading to lateral hip pain, with US playing an increasingly important role for both evaluation and image-guided treatment. Muscle injuries and athletic pubalgia are common in athletes. Lastly, snapping hip syndrome and Morel-Lavallée lesions are two less common but nonetheless important considerations. © RSNA, 2016.
Mao, Yuanqing; Xu, Chen; Xu, Jiawei; Li, Huiwu; Liu, Fengxiang; Yu, Degang; Zhu, Zhenan
2015-10-01
Revision total hip arthroplasty (THA) is challenging if severe periacetabular bone loss is present. Here we describe a method that uses a customised cage to reconstruct an acetabulum with a massive bone defect. Designed with the aid of the rapid prototyping technique, a customised cage with a hook, crest and flange or braids was made, and then utilized to reconstruct severe compromised acetabulum in revision THA since 2001. Twenty-two patients (23 hips) were included in this study. The mean patient age at the time of surgery was 60.9 years (range, 38-80 years). Three hips had massive acetabular bone defects of Paprosky type IIIA and 20 of type IIIB. The Harris hip score was used to evaluate hip function. Radiographs were taken to evaluate loosening of the cage and resorption of allograft bone. The average follow up was 81.6 ± 24.9 months. The mean Harris hip score improved from 39.6 pre-operatively to 80.9 at the final follow-up. There were no instances of deep infection, severe venous thrombosis, and nerve palsy. One patient who had an intra-operative rupture of the superior acetabular artery was successfully treated using the haemostatic suturing technique. Two patients experienced dislocation at post-operative days four and six, respectively, and both were treated with closed reduction and skin traction for three weeks. The present study demonstrates that a customised cage may be a promising option for THA revision of severely compromised acetabula. Extended follow-up is necessary to evaluate the long-term performance of this approach.
Babiak, Ireneusz
2012-07-03
Deep infection of a joint endoprosthesis constitutes a threat to the stability of the implant and joint function. It requires a comprehensive and interdisciplinary approach, involving the joint revision and removal of the bacterial biofilm from all tissues, the endoprosthesis must be often removed and bone stock infection treated. The paper presents the author's experience with the use of acrylic cement spacers, custom-made during the surgery and containing low dose of an antibiotic supplemented with 5% of a selected, targeted antibiotic for the infection of hip and knee endoprostheses. 33 two-stage revisions of knee and hip joints with the use of a spacer were performed. They involved 24 knee joints and 9 hip joints. The infections were mostly caused by staphylococci MRSA (18) and MSSA (8), and in some cases Enterococci (4), Salmonella (1), Pseudomonas (1) and Acinetobacter (1). The infection was successfully treated in 31 out of 33 cases (93.93%), including 8 patients with the hip infection and 23 patients with the knee infection. The endoprosthesis was reimplanted in 30 cases: for 7 hips and 23 knees, in 3 remaining cases the endoprosthesis was not reimplanted. Mechanical complications due to the spacer occurred in 4 cases: 3 dislocations and 1 fracture (hip spacer). The patients with hip spacers were ambulatory with a partial weight bearing of the operated extremity and those with knee spacers were also ambulatory with a partial weight bearing, but the extremity was initially protected by an orthosis. The spacer enables to maintain a limb function, and making it by hand allows the addition of the specific bacteria targeted antibiotic thus increasing the likelihood of the effective antibacterial treatment.
Patterson, Diana C; Price, Andrew E
2018-05-01
Debate remains about the appropriate treatment of the asymptomatic side following treatment of a unilateral slipped capital femoral epiphysis (SCFE). A 12-year-old boy with a seizure disorder presented with an unstable SCFE on the left hip following a seizure. He underwent percutaneous pinning of the left only. At 8 months postoperatively, he returned with an unstable slip of the right hip, again following a seizure. No literature discussing the treatment of patients with risk of SCFE and seizure disorders was identified. Further study may identify an increased incidence of contralateral slip following an initial slip in this population. If a greater risk exists, contralateral prophylactic fixation at time of index surgery may be indicated.
Thermo-mechanical process for treatment of welds
DOE Office of Scientific and Technical Information (OSTI.GOV)
Malik, R K
1980-03-01
Benefits from thermo-mechanical processing (TMP) of austenitic stainless steel weldments, analogous to hot isostatic pressing (HIP) of castings, most likely result from compressive plastic deformation, enhanced diffusion, and/or increased dislocation density. TMP improves ultrasonic inspectability of austenitic stainless steel welds owing to: conversion of cast dendrites into equiaxed austenitic grains, reduction in size and number of stringers and inclusions, and reduction of delta ferrite content. TMP induces structural homogenization and healing of void-type defects and thus contributes to an increase in elongation, impact strength, and fracture toughness as well as a significant reduction in data scatter for these properties. Anmore » optimum temperature for TMP or HIP of welds is one which causes negligible grain growth and an acceptable reduction in yield strength, and permits healing of porosity.« less
Performance of Non-Cemented, Hemispherical, Rim-Fit, Hydroxyapatite Coated Acetabular Component.
John, Thomas K; Ghosh, Gaurav; Ranawat, Chitranjan S; Ranawat, Amar S; Meftah, Morteza
2015-12-01
The purpose of this study was to assess the durability of a non-cemented, hemispherical rim-fit, hydroxyapatite coated cup with a highly cross-linked polyethylene in 223 total hip arthroplasties. At 6-years follow-up (range, 5-9), there were no cup revisions for osteolysis or loosening. Radiologic evidence of osseointegration was based on presence of Stress Induced Reactive Cancellous Bone and radial trabeculae, seen in 47% and 93% of cups, respectively; both were most prevalent in Zone 1. There was no interference demarcation in any zones. Two cups were revised (0.9%): one for dislocation and another for infection. The Kaplan-Meier survivorship for cup revision for any failure (infection, dislocation) was 99% and for mechanical failure (osteolysis, loosening) was 100%. This design has excellent safety, efficacy and durability. Copyright © 2015 Elsevier Inc. All rights reserved.
Li, Wei; Zhou, Yi-Xin; Wu, Jian; Xu, Hui; Ji, Song-Jie
2009-02-15
To evaluate the bone refilling in the interface between the trabecular metal (TM) acetabular shell and the bone surface according to consecutive X film measuring after surgery. From July 2006 to July 2007, 35 patients (40 hips) accepted total hip replacement using trabecular metal monoblock acetabular cup system (TM). The cup was made of a ellipse shaped press fit Tantalum shell and high cross-linked PE liner (Longevity) with 28 mm inner diameter. The patients demography was: 16 male (20 hips), 19 female (20 hips), 5 bilateral hip replacements, age from 41 - 71 (mean 53), including 18 avascular necrosis hips, 16 osteoarthritis hips (including those secondary to a dysplasia hip), 4 avascular necrosis hips after femoral neck fracture, 2 Ankylosis Spondylitis. All the 40 total hip replacements used posterior approach, using hemispherical acetabular reamer and 2 mm press fit of final metal shell without screw fixation. The consecutive X film was taken at the end time of surgery and 2, 6, 12, 24 weeks, and 12 months. The clinical results was evaluate according to Harris scoring system, and the standard pelvis AP X film was measured at the interface between metal shell and the acetabular bone surface, witch was divided into five regions (A, B, C, D, E). Totally 32 patients (37 hips) were followed with average 8.7 months (7 - 12 months). The Harris before surgery was 50.5 (32 - 85), promoted to 91.0 (72 - 100), including 29 excellent, 6 good, 2 fair, and the total excellent and good rate was 94.6%. Complications include 4 patients leg length discrepancy from 1 - 2 cm, 3 patients moderate thigh pain and released after conservative therapy. No infection and dislocation was found. Twenty-one patients (23 hips) were found lucent line at the bone-metal interface from 1 - 5 mm, most common in B region and BC boundary than C, D, and CD boundary. All the patients followed was found the lucent line disappeared and refilled with bone at X film 24 weeks after surgery, however, no patients was found osteolysis and cup migration. The trabecular metal has strong capacity of bone conductive and bone inducement.
Talia, Adrian J; Coetzee, Cassandra; Tirosh, Oren; Tran, Phong
2018-01-08
Total hip arthroplasty is one of the most commonly performed surgical procedures worldwide. There are a number of surgical approaches for total hip arthroplasty and no high-level evidence supporting one approach over the other. Each approach has its unique benefits and drawbacks. This trial aims to directly compare the three most common surgical approaches for total hip arthroplasty. This is a single-centre study conducted at Western Health, Melbourne, Australia; a large metropolitan centre. It is a pragmatic, parallel three-arm, randomised controlled trial. Sample size will be 243 participants (81 in each group). Randomisation will be secure, web-based and managed by an independent statistician. Patients and research team will be blinded pre-operatively, but not post-operatively. Intervention will be either direct anterior, lateral or posterior approach for total hip arthroplasty, and the three arms will be directly compared. Participants will be aged over 18 years, able to provide informed consent and recruited from our outpatients. Patients who are having revision surgery or have indications for hip replacement other than osteoarthritis (i.e., fracture, malignancy, development dysplasia) will be excluded from the trial. The Oxford Hip Score will be determined for patients pre-operatively and 6 weeks, 6, 12 and 24 months post-operatively. The Oxford Hip Score at 24 months will be the primary outcome measure. Secondary outcome measures will be dislocation, infection, intraoperative and peri-prosthetic fracture rate, length of hospital stay and pain level, reported using a visual analogue scale. Many studies have evaluated approaches for total hip arthroplasty and arthroplasty registries worldwide are now collecting this data. However no study to date has compared these three common approaches directly in a randomised fashion. No trial has used patient-reported outcome measures to evaluate success. This pragmatic study aims to identify differences in patient perception of total hip arthroplasty depending on surgical approach. Australian New Zealand Clinical Trials Registry, ACTRN12617000272392 . Registered on 22 February 2017.
Schlegelmilch, Michael; Rashiq, Saifee; Moreau, Barbara; Jarrín, Patricia; Tran, Bach; Chuck, Anderson
2017-01-01
Few charitable overseas surgical missions produce cost-effectiveness analyses of their work. We compared the pre- and postoperative health status for 157 total hip arthroplasty (THA) patients operated on from 2007 to 2011 attended by an annual Canadian orthopedic mission to Ecuador to determine the quality-adjusted life years (QALYs) gained. The costs of each mission are known. The cost per surgery was divided by the average lifetime QALYs gained to estimate an incremental cost-effectiveness ratio (ICER) in Canadian dollars per QALY. The average lifetime QALYs (95% CI) gained were 1.46 (1.4-1.5), 2.5 (2.4-2.6), and 2.9 (2.7-3.1) for unilateral, bilateral, and staged (two THAs in different years) operations, respectively. The ICERs were $4,442 for unilateral, $2,939 for bilateral, and $4392 for staged procedures. Seventy percent of the mission budget was spent on the transport and accommodation of volunteers. THA by a Canadian short-stay surgical team was highly cost-effective, according to criteria from the National Institute for Health and Care Excellence and the World Health Organization. We encourage other international missions to provide similar cost-effectiveness data to enable better comparison between mission types and between mission and nonmission care.
Effects of hydroxyapatite coating of cups used in hip revision arthroplasty
2012-01-01
Background and purpose Coating of acetabular revision implants with hydroxyapatite (HA) has been proposed to improve ingrowth and stability. We investigated whether HA coating of revision cups can reduce the risk of any subsequent re-revision. Methods We studied uncemented cups either with or without HA coating that were used at a primary acetabular revision and registered in the Swedish Hip Arthroplasty Register (SHAR). 2 such cup designs were identified: Harris-Galante and Trilogy, both available either with or without HA coating. These cups had been used as revision components in 1,780 revisions of total hip arthroplasties (THA) between 1986 and 2009. A Cox proportional hazards model including the type of coating, age at index revision, sex, cause of cup revision, cup design, the use of bone graft at the revision procedure, and the type of cup fixation at primary THA were used to calculate adjusted risk ratios (RRs with 95% CI) for re-revision for any reason or due to aseptic loosening. Results 71% of the cups were coated with HA and 29% were uncoated. At a mean follow-up time of 6.9 (0–24) years, 159 (9%) of all 1,780 cups had been re-revised, mostly due to aseptic loosening (5%), dislocation (2%), or deep infection (1%). HA coating had no significant influence on the risk of re-revision of the cup for any reason (RR = 1.4, CI: 0.9–2.0) or due to aseptic loosening (RR = 1.1, 0.6–1.9). In contrast, HA coating was found to be a risk factor for isolated liner re-revision for any reason (RR = 1.8, CI: 1.01–3.3). Age below 60 years at the index cup revision, dislocation as the cause of the index cup revision, uncemented cup fixation at primary THA, and use of the Harris-Galante cup also increased the risk of re-revision of the cup. In separate analyses in which isolated liner revisions were excluded, bone grafting was found to be a risk factor for re-revision of the metal shell due to aseptic loosening (RR = 2.1, CI: 1.05–4.2). Interpretation We found no evidence to support the notion that HA coating improves the performance of the 2 studied cup designs in revision arthroplasty. In contrast, patient-related factors such as younger age and dislocation as the reason for cup revision, and technical factors such as the choice of revision cup were found to influence the risk of subsequent re-revision of the cup. The reason for inferior results after revision of uncemented cups is not known, but it is possible that these hips more often had pronounced bone loss at the index cup revision. PMID:22937978
Reduction of metallosis in hip implant using thin film coating
NASA Astrophysics Data System (ADS)
Rajeshshyam, R.; Chockalingam, K.; Gayathri, V.; Prakash, T.
2018-04-01
Hip implant finds its emerging attraction due to it continuous demand over the years. The hip implants (femoral head) and acetabulum cup) mainly fabricated by metals such as stainless steel, cobalt chrome and titanium alloys, other than that ceramics and polyethylene have been used. The metal-on-metal hip implant was found to be best implant material for most of the surgeons due to its high surface finish, low wear rate and low chance of dislocation from its position after implanting. Where in metal based hip implant shows less wear rate of 0.01mm3/year. Metal-on-metal implant finds its advantage over other materials both in its mechanical and physical stability against human load. In M-O-M Cobalt- chromium alloys induce metal allergy. The metal allergy (particulate debris) that is generated by wear, fretting, fragmentation and which is unavoidable when a prosthesis is implanted, can induce an inflammatory reaction in some circumstances. The objectives of this research to evaluate thin film coating with Nano particle additives to reduce the wear leads to regarding metal ion release. Experimental results reveals that thin film Sol-Gel coating with 4wt. % of specimen reduced the cobalt and chromium ion release and reduces the wear rate. Wear rate reduced by 98% for 4wt. % graphene in 20N and 95% for 4wt. % graphene in 10N.
Rutenberg, Tal Frenkel; Warshevski, Yaniv; Gold, Aviram; Shasha, Nadav; Snir, Nimrod; Chechik, Ofir; Dolkart, Oleg; Eilig, Dynai; Herman, Amir; Rath, Ehud; Kramer, Moti; Drexler, Michael
2018-05-08
The Mayo metaphysical conservative femoral stem (Zimmer, Warsaw, Indiana) is a wedge-shaped implant designed to transfer loads proximally, reduce femoral destruction, and enable the preservation of bone stock in the proximal femur. Thus, it is a potentially preferred prosthesis for active, non-elderly patients who may require additional future surgeries. This retrospective case study analyzed the outcomes of consecutive patients who underwent total hip replacements with this stem between May 2001 and February 2013. All patients underwent clinical assessment, radiological evaluation for the presence and development of radiolucent lines, and functional assessment (numerical analog scale, Harris hip score, and Short Form-12 questionnaire). Ninety-five hips (79 patients) were available for analysis. The patients' mean age was 43 years (range, 18-64 years), and the mean follow-up was 97 months (range, 26.9-166 months). The postoperative clinical assessments and functional assessments revealed significant improvements. Sixteen patients (20.3%) had 18 orthopedic complications, the most common of which were an intraoperative femoral fracture and implant dislocation requiring revision surgeries in 10 hips (10.5%). Radiological analysis revealed evidence of femoral remodeling in 64 (67.4%) implants, spot welds (neocortex) in 35 (36.8%), and osteolysis in 3 (3.2%). These results suggest that the conservative hip femoral implant has an unacceptable complication rate for non-elderly patients. [Orthopedics. 201x; xx(x):xx-xx.]. Copyright 2018, SLACK Incorporated.
HiL simulation in biomechanics: a new approach for testing total joint replacements.
Herrmann, Sven; Kaehler, Michael; Souffrant, Robert; Rachholz, Roman; Zierath, János; Kluess, Daniel; Mittelmeier, Wolfram; Woernle, Christoph; Bader, Rainer
2012-02-01
Instability of artificial joints is still one of the most prevalent reasons for revision surgery caused by various influencing factors. In order to investigate instability mechanisms such as dislocation under reproducible, physiologically realistic boundary conditions, a novel test approach is introduced by means of a hardware-in-the-loop (HiL) simulation involving a highly flexible mechatronic test system. In this work, the underlying concept and implementation of all required units is presented enabling comparable investigations of different total hip and knee replacements, respectively. The HiL joint simulator consists of two units: a physical setup composed of a six-axes industrial robot and a numerical multibody model running in real-time. Within the multibody model, the anatomical environment of the considered joint is represented such that the soft tissue response is accounted for during an instability event. Hence, the robot loads and moves the real implant components according to the information provided by the multibody model while transferring back the position and resisting moment recorded. Functionality of the simulator is proved by testing the underlying control principles, and verified by reproducing the dislocation process of a standard total hip replacement. HiL simulations provide a new biomechanical testing tool for analyzing different joint replacement systems with respect to their instability behavior under realistic movements and physiological load conditions. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
[Tumor prostheses : Important in modern revision arthroplasty].
Hillmann, A; Ipach, I
2015-05-01
Due to demographic aging, an increasing number of revision arthroplasty procedures is expected during upcoming years. While the use of a megaprosthesis for bone reconstruction after tumor resection is gold standard, this type of prosthesis still meets with reservation in the field of revision arthroplasty because of numerous risk factors. The purpose of this article is to present the importance of modular megaprostheses in revision arthroplasty, taking into consideration the risks of periprosthetic infection, aseptic loosening, material failure, and hip dislocation. Because of improvements in the field of megaprostheses during the last 30 years, the risks after implantation of this type of prosthesis have significantly decreased. The risk of periprosthetic infection has been reduced about 1/3 by the use of silver surface coating. Improvements in stem design, cement technique, and the additional use of locking screws have minimized the risk of aseptic loosening. Improvements in material composition have reduced the risk of material failure. The risk of hip dislocation could also be minimized by careful tissue preparation and appropriate suture technique. There is no need for the conservative use of megaprostheses in revision arthroplasty. There are many benefits in the use of megaprostheses in multimorbid patients (i.e., reduced operating time, the possibility of early full weight bearing, and a reduced risk of periprosthetic infection by the use of silver surface coating) instead of complex bone reconstruction during revision arthroplasty.
Transient peripartum osteoporosis of the femoral head in first and third pregnancy.
Truszczyńska, Aleksandra; Walczak, Piotr; Rapała, Kazimierz
2012-01-01
The aim of this article was to present transient peripartum femoral head osteoporosis. This very rare condition occurred twice in our patient-a woman in her 30s. The cases described in the literature were mostly unilateral, with bilateral hip involvement noted much less frequently. In our patient, transient osteoporosis occurred in the third trimester of her first pregnancy in the right hip, her second pregnancy was uncomplicated, and in the third trimester of the patient's third pregnancy, osteoporotic changes were noted in the left hip joint. The patient breastfed her first and third babies only 3 wk each. She breastfed her second baby for 4 mo. The diagnostic workup was based on the clinical examination and radiographic/magnetic resonance imaging, which revealed bone marrow edema, and the dual-energy X-ray absorptiometry scans. The treatment consisted in core decompression of the femoral head (foragé), unloading of the hip using crutches as well as administration of calcitonin and calcium supplements. Complete recovery of the femoral heads was achieved. The follow-up time was 7 yr. Copyright © 2012 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.
Hip Strength in Patients with Quadriceps Strength Deficits after ACL Reconstruction.
Bell, David R; Trigsted, Stephanie M; Post, Eric G; Walden, Courtney E
2016-10-01
Quadriceps strength deficits persist for years after anterior cruciate ligament (ACL) reconstruction, and patients with these deficits often shift torque demands away from the knee extensors to the hip during functional tasks. However, it is not clear how quadriceps strength deficits may affect hip strength. Therefore, the purpose of this study was to investigate differences in lower extremity strength in individuals with ACL reconstruction with differing levels of quadriceps strength asymmetry. Isometric strength was recorded bilaterally in 135 participants (73 control and 62 with unilateral ACL reconstruction, time from surgery = 30.9 ± 17.6 months) from the knee extensors and flexors, hip extensors and abductors, and hip internal and external rotator muscle groups. Symmetry indices (limb symmetry index (LSI)) were created based on quadriceps strength, and subjects with ACL reconstruction were subdivided (high quadriceps (LSI ≥ 90%), n = 37; low quadriceps (LSI < 85%), n = 18). Individual group (control vs high quadriceps vs low quadriceps) by limb (reconstructed/nondominant vs healthy/dominant) repeated-measures ANOVA was used to compare strength (%BW) for each of the six joint motions of interest (knee extensors/flexors, hip abductors/extensors/external, and internal rotators) while controlling for time from surgery. An interaction was observed for quadriceps strength (P < 0.001), and the reconstructed limb in the low quadriceps group was weaker than all other limbs. A main effect for group was observed with the low quadriceps group having greater hip extension (P = 0.007) strength in both limbs compared with the other groups. Knee flexion strength was weaker in the reconstructed limb of the high quadriceps group (P = 0.047) compared with all other groups and limbs. Individuals with ACL reconstruction and involved limb quadriceps weakness have greater hip extension strength in both limbs compared with patients with bilateral strength symmetry and controls.
Hando, Ben R; Gill, Norman W; Walker, Michael J; Garber, Mathew
2012-01-01
Objectives: Describe short- and long-term outcomes observed in individuals with hip osteoarthritis (OA) treated with a pre-selected, standardized set of best-evidence manual therapy and therapeutic exercise interventions. Methods: Fifteen consecutive subjects (9 males, 6 females; mean age: 52±7.5 years) with unilateral hip OA received an identical protocol of manual therapy and therapeutic exercise interventions. Subjects attended 10 treatment sessions over an 8-week period for manual therapy interventions and performed the therapeutic exercise as a home program. Results: Baseline to 8-week follow-up outcomes were as follows: Harris Hip Scale (HHS) scores improved from 60.3(±10.4) to 80.7(±10.5), Numerical Pain Rating Scale (NPRS) scores improved from 4.3(±1.9) to 2.0(±1.9), hip flexion range of motion (ROM) improved from 99 degrees (±10.6) to 127 degrees (±6.3) and hip internal rotation ROM improved from 19 degrees (±9.1) to 31 degrees (±11.5). Improvements in HHS, NPRS, and hip ROM measures reached statistical significance (P<0.05) at 8-weeks and remained significant at the 29-week follow-up. Mean changes in NPRS and HHS scores exceeded the minimal clinically important difference (MCID) at 8-weeks and for the HHS scores alone at 29 weeks. The 8 and 29 week mean Global Rating of Change scores were 5.1(±1.4) and 2.1(±4.2), respectively. Improved outcomes observed following a pre-selected, standardized treatment protocol were similar to those observed in previous studies involving impairment-based manual therapy and therapeutic exercise for hip OA. Future studies might directly compare the two approaches. Discussion: PMID:24179327
Hando, Ben R; Gill, Norman W; Walker, Michael J; Garber, Mathew
2012-11-01
Describe short- and long-term outcomes observed in individuals with hip osteoarthritis (OA) treated with a pre-selected, standardized set of best-evidence manual therapy and therapeutic exercise interventions. Fifteen consecutive subjects (9 males, 6 females; mean age: 52±7.5 years) with unilateral hip OA received an identical protocol of manual therapy and therapeutic exercise interventions. Subjects attended 10 treatment sessions over an 8-week period for manual therapy interventions and performed the therapeutic exercise as a home program. Baseline to 8-week follow-up outcomes were as follows: Harris Hip Scale (HHS) scores improved from 60.3(±10.4) to 80.7(±10.5), Numerical Pain Rating Scale (NPRS) scores improved from 4.3(±1.9) to 2.0(±1.9), hip flexion range of motion (ROM) improved from 99 degrees (±10.6) to 127 degrees (±6.3) and hip internal rotation ROM improved from 19 degrees (±9.1) to 31 degrees (±11.5). Improvements in HHS, NPRS, and hip ROM measures reached statistical significance (P<0.05) at 8-weeks and remained significant at the 29-week follow-up. Mean changes in NPRS and HHS scores exceeded the minimal clinically important difference (MCID) at 8-weeks and for the HHS scores alone at 29 weeks. The 8 and 29 week mean Global Rating of Change scores were 5.1(±1.4) and 2.1(±4.2), respectively. Improved outcomes observed following a pre-selected, standardized treatment protocol were similar to those observed in previous studies involving impairment-based manual therapy and therapeutic exercise for hip OA. Future studies might directly compare the two approaches.
Reliability and validity of functional performance tests in dancers with hip dysfunction.
Kivlan, Benjamin R; Carcia, Christopher R; Clemente, F Richard; Phelps, Amy L; Martin, Robroy L
2013-08-01
Quasi-experimental, repeated measures. Functional performance tests that identify hip joint impairments and assess the effect of intervention have not been adequately described for dancers. The purpose of this study was to examine the reliability and validity of hop and balance tests among a group of dancers with musculoskeletal pain in the hip region. NINETEEN FEMALE DANCERS (AGE: 18.90±1.11 years; height: 164.85±6.95 cm; weight: 60.37±8.29 kg) with unilateral hip pain were assessed utilizing the cross-over reach, medial triple hop, lateral triple hop, and cross-over hop tests on two occasions, 2 days apart. Test-retest reliability and comparisons between the involved and uninvolved side for each respective test were determined. Intra-class correlation coefficients for the functional performance tests ranged from 0.89-0.96. The cross-over reach test had a SEM of 2.79 cm and a MDC of 7.73 cm. The medial and lateral triple hop tests had SEM values of 7.51 cm and 8.17 cm, and MDC values of 20.81 cm and 22.62 cm, respectively. The SEM was 0.15 seconds and the MDC was 0.42 seconds for the cross-over hop test. Performance on the medial triple hop test was significantly less on the involved side (370.21±38.26 cm) compared to the uninvolved side (388.05±41.49 cm); t(18) = -4.33, p<0.01. The side-to-side comparisons of the cross-over reach test (involved mean=61.68±10.9 cm; uninvolved mean=61.69±8.63 cm); t(18) = -0.004, p=0.99, lateral triple hop test (involved mean=306.92±35.79 cm; uninvolved mean=310.68±24.49 cm); t(18) = -0.55, p=0.59, and cross-over hop test (involved mean=2.49±0.34 seconds; uninvolved mean= 2.61±0.42 seconds; t(18) = -1.84, p=0.08) were not statistically different between sides. The functional performance tests used in this study can be reliably performed on dancers with unilateral hip pain. The medial triple hop test was the only functional performance test with evidence of validity in side-to-side comparisons. These results suggest that the medial triple hop test may be a reliable and valid functional performance test to assess impairments related to hip pain among dancers. 3b. Non-consecutive cohort study.
RELIABILITY AND VALIDITY OF FUNCTIONAL PERFORMANCE TESTS IN DANCERS WITH HIP DYSFUNCTION
Carcia, Christopher R.; Clemente, F. Richard; Phelps, Amy L.; Martin, RobRoy L.
2013-01-01
Study Design: Quasi-experimental, repeated measures. Purpose/Background: Functional performance tests that identify hip joint impairments and assess the effect of intervention have not been adequately described for dancers. The purpose of this study was to examine the reliability and validity of hop and balance tests among a group of dancers with musculoskeletal pain in the hip region. Methods: Nineteen female dancers (age: 18.90±1.11 years; height: 164.85±6.95 cm; weight: 60.37±8.29 kg) with unilateral hip pain were assessed utilizing the cross-over reach, medial triple hop, lateral triple hop, and cross-over hop tests on two occasions, 2 days apart. Test-retest reliability and comparisons between the involved and uninvolved side for each respective test were determined. Results: Intra-class correlation coefficients for the functional performance tests ranged from 0.89-0.96. The cross-over reach test had a SEM of 2.79 cm and a MDC of 7.73 cm. The medial and lateral triple hop tests had SEM values of 7.51 cm and 8.17 cm, and MDC values of 20.81 cm and 22.62 cm, respectively. The SEM was 0.15 seconds and the MDC was 0.42 seconds for the cross-over hop test. Performance on the medial triple hop test was significantly less on the involved side (370.21±38.26 cm) compared to the uninvolved side (388.05±41.49 cm); t(18) = −4.33, p<0.01. The side-to-side comparisons of the cross-over reach test (involved mean=61.68±10.9 cm; uninvolved mean=61.69±8.63 cm); t(18) = −0.004, p=0.99, lateral triple hop test (involved mean=306.92±35.79 cm; uninvolved mean=310.68±24.49 cm); t(18) = −0.55, p=0.59, and cross-over hop test (involved mean=2.49±0.34 seconds; uninvolved mean= 2.61±0.42 seconds; t(18) = −1.84, p=0.08) were not statistically different between sides. Conclusion: The functional performance tests used in this study can be reliably performed on dancers with unilateral hip pain. The medial triple hop test was the only functional performance test with evidence of validity in side-to-side comparisons. These results suggest that the medial triple hop test may be a reliable and valid functional performance test to assess impairments related to hip pain among dancers. Level of Evidence: 3b. Non-consecutive cohort study PMID:24175123
Dalén, Nils; Berg, Hans E
2010-01-01
Background Patients with hip osteoarthritis (OA) have muscular weakness, impaired balance, and limp. Deficits in the different limb muscles and their recovery courses are largely unknown, however. We hypothesized that there is persisting muscular weakness in lower limb muscles and an impaired balance and gait 2 years after THA. Patients and methods 20 elderly patients with unilateral OA were assessed before, and 6 and 24 months after surgery for maximal voluntary isometric strength of hip and knee muscles and by gait analysis, postural stability, and clinical scores (HHS, SF-36, EuroQoL). Results Hip muscles showed a remaining 6% weakness compared to the contralateral healthy limb 2 years after THA. Preoperatively and 6 months postoperatively, that deficit was 18% and 12%, respectively. Knee extensors fully recovered a preoperative 27% deficit after 2 years. Gait analysis demonstrated a shorter single stance phase for the OA limb compared to healthy limb preoperatively, that had already recovered at the 6-month follow-up. Balance of two-foot standing showed improvement in both sagittal and lateral sway after operation. All clinical scores improved. Interpretation Muscle strength data demonstrated a slow but full recovery of muscles acting about the knee, but there was still a deficit in hip muscle strength 2 years after THA. Gait and balance recovered after the operation. To accelerate improvement in muscular strength after THA, postoperative training should probably be more intense and target hip abductors. PMID:20367414
[The Use of Jumbo Cups in Revision Total Hip Arthroplasty].
von Roth, Philipp; Wassilew, Georgi I
2017-10-01
Extra-large uncemented jumbo cups are among the most common methods of acetabular revision. Jumbo cups do not contribute to bone stock restoration, and in the case of a subsequent revision, an even larger bone defect is to be expected. Thus, understanding long-term survival is essential. The present article discusses the literature relevant to this topic and addresses technical and implant-specific characteristics of jumbo cups. In summary, jumbo cups show an acceptable long-term survival rate, with aseptic loosening as the most common reason for revision and dislocation being the most common complication. Through the development of alternative revision systems, jumbo cups have lost their importance in today's practice. However, they can serve as a benchmark for studies of newer technologies in revision total hip arthroplasty. Georg Thieme Verlag KG Stuttgart · New York.
The anteromedial approach to the psoas tendon in patients with cerebral palsy
Poonnoose, Pradeep M.; Palocaren, Thomas
2007-01-01
Purpose Release of the psoas tendon for flexion deformity of the hip in children with cerebral palsy has traditionally been performed at the pelvic brim, lateral to the neurovascular bundle, or at its insertion into the lesser trochanter. As the psoas tendon is lateral to the pectineus, the traditional exposure of the tendon through an approach medial to the pectineus is limited by the extent to which the pectineus can be retracted proximally. Technical note We describe the use of the anteromedial approach used for the developmentally dislocated hip to expose the psoas tendon between the pectineus and the neurovascular bundle. This provides a much better visualisation of the tendon as it crosses the superior pubic ramus to its insertion. The use of this approach has not been described in cerebral palsy. PMID:19308518
The Safe Zone Range for Cup Anteversion Is Narrower Than for Inclination in THA.
Murphy, William S; Yun, Ho Hyun; Hayden, Brett; Kowal, Jens H; Murphy, Stephen B
2018-02-01
Cup malposition is a common cause of impingement, limitation of ROM, acceleration of bearing wear, liner fracture, and instability in THA. Previous studies of the safe zone based on plain radiographs have limitations inherent to measuring angles from two-dimensional projections. The current study uses CT to measure component position in stable and unstable hips to assess the presence of a safe zone for cup position in THA. (1) Does acetabular component orientation, when measured on CT, differ in stable components and those revised for recurrent instability? (2) Do CT data support historic safe zone definitions for component orientation in THA? We identified 34 hips that had undergone revision of the acetabulum for recurrent instability that also had a CT scan of the pelvis between August 2003 and February 2017. We also identified 175 patients with stable hip replacements who also had a CT study for preoperative planning and intraoperative navigation of the contralateral side. For each CT study, one observer analyzed major factors including acetabular orientation, femoral anteversion, combined anteversion (the sum of femoral and anatomic anteversion), pelvic tilt, total offset difference, head diameter, age, sex, and body mass index. These measures were then compared among stable hips, hips with cup revision for anterior instability, and hips with cup revision for posterior instability. We used a clinically relevant measurement of operative anteversion and inclination as opposed to the historic use of radiographic anteversion and inclination. The percentage of unstable hips in the historic Lewinnek safe zone was calculated, and a new safe zone was proposed based on an area with no unstable hips. Anteriorly unstable hips compared with stable hips had higher operative anteversion of the cup (44° ± 12° versus 31° ± 11°, respectively; mean difference, 13°; 95% confidence interval [CI], 5°-21°; p = 0.003), tilt-adjusted operative anteversion of the cup (40° ± 6° versus 26° ± 10°, respectively; mean difference, 14°; 95% CI, 10°-18°; p < 0.001), and combined tilt-adjusted anteversion of the cup (64° ± 10° versus 54° ± 19°, respectively; mean difference, 10°; 95% CI, 1°-19°; p = 0.028). Posteriorly unstable hips compared with stable hips had lower operative anteversion of the cup (19° ± 15° versus 31° ± 11°, respectively; mean difference, -12°; 95% CI, -5° to -18°; p = 0.001), tilt-adjusted operative anteversion of the cup (19° ± 13° versus 26° ± 10°, respectively; mean difference, -8°; 95% CI, -14° to -2°; p = 0.014), pelvic tilt (0° ± 6° versus 4° ± 6°, respectively; mean difference, -4°; 95% CI, -7° to -1°; p = 0.007), and anatomic cup anteversion (25° ± 18° versus 34° ± 12°, respectively; mean difference, -9°; 95% CI, -1° to -17°; p = 0.033). Thirty-two percent of the unstable hips were located in the Lewinnek safe zone (11 of 34; 10 posterior dislocations, one anterior dislocation). In addition, a safe zone with no unstable hips was identified within 43° ± 12° of operative inclination and 31° ± 8° of tilt-adjusted operative anteversion. The current study supports the notion of a safe zone for acetabular component orientation based on CT. However, the results demonstrate that the historic Lewinnek safe zone is not a reliable predictor of future stability. Analysis of tilt-adjusted operative anteversion and operative inclination demonstrates a new safe zone where no hips were revised for recurrent instability that is narrower for tilt-adjusted operative anteversion than for operative inclination. Tilt-adjusted operative anteversion is significantly different between stable and unstable hips, and surgeons should therefore prioritize assessment of preoperative pelvic tilt and accurate placement in operative anteversion. With improvements in patient-specific cup orientation goals and acetabular component placement, further refinement of a safe zone with CT data may reduce the incidence of cup malposition and its associated complications. Level III, diagnostic study.
de Thomasson, E; Guingand, O; Terracher, R; Mazel, C
2001-09-01
We conducted a retrospective study to assess morbidity and mortality in patients undergoing revision total hip arthroplasty (THA) procedures. Perioperative complications were recorded in 181 revision procedures (162 patients) performed between January 1995 and March 1999 (117 bipolar revisions and 64 acetabular isolated revisions). There were 86 complications (68 patients) leading to 21 new revisions. About half (50/86) were related to the surgical procedure (dislocation, femoral fracture, infection.). Life-threatening complications (3.6%) ended in patient death in 1.6% of the cases. Complications were more frequent in patients with an ASA score=3 (p<0.01) or aged over 75 years (p<0.05). Age was also predictive of femoral misalignment and fracture (p<0.05). Dislocations (8.8%) were observed more frequently in patients who had undergone more than 2 procedures prior to the revision (p<0.05) (4.8% of the dislocations in patients undergoing a first revision procedure and 14.3% in the others). In addition, peroperative blood loss and duration of the procedure were significantly greater in case of bipolar replacement than for isolated acetabular replacement (sigma > 1.96). Our experience and data in the literature point to the important age factor in the development of complications. Preservation of a well-fixed femoral component does not appear to worsen prognosis and leads to fewer complications than bipolar changes. The decision to revise a THA must take into consideration the functional impairment but also the risks inherent in revision procedures, particularly in old patients who have undergone several procedures. Revising the acetabular component alone can be an interesting option if the femoral component remains well-fixed although our follow-up is insufficient to determine whether this attitude provides better long-term outcome than complete biopolar revision. Better patient selection and improved operative technique, in particular in femur preparation, should help reduce morbidity and mortality in this type of procedure.
Mitter, Diana; Krakow, Deborah; Farrington-Rock, Claire; Meinecke, Peter
2008-03-15
We report on a 5-year-old boy with spondylocarpotarsal synostosis (SCT) syndrome who presents with disproportionate short stature, thoracic scoliosis, pes planus, dental enamel hypoplasia, unilateral conductive hearing loss and mild facial dysmorphisms. Radiographs showed abnormal segmentation of the spine with block vertebrae and carpal synostosis. In addition to the typical phenotype of SCT syndrome, he showed pronounced delay of carpal bone age and bilateral epiphyseal dysplasia of the proximal femora. The patient's father has mild short stature and unilateral hip dysplasia. Molecular studies of the filamin B gene (FLNB) revealed a homozygous mutation in the index patient while both parents were heterozygous for the mutation. In this report we expand the phenotype of SCT syndrome in a patient with a causal FLNB mutation. (c) 2008 Wiley-Liss, Inc.
Shanmuganathan, K; Mirvis, S E; Levine, A M
1994-11-01
Imaging studies of patients with rotational facet injuries of the cervical spine were retrospectively reviewed to determine the prevalence and pattern of associated fractures, to correlate injury pattern with recommended surgical stabilization, and to assess neurologic outcome. Radiographs and CT scans obtained for 40 consecutive patients with rotational facet injuries of the cervical spine during a 70-month period were retrospectively reviewed to determine injury level, presence, and orientation of facet fractures, and concurrent nonfacet injuries. Imaging findings were reviewed to assess the likelihood of instability and to determine the most appropriate stabilization requirement. Medical records were reviewed to ascertain mechanism of injury, initial neurologic deficit, and surgical findings. Among the 40 patients with cervical rotational facet injuries, 11 (27%) had pure unilateral facet dislocation or subluxation without associated fractures, and 29 (73%) had concurrent facet fractures involving the inferior facet of the rotated vertebra (n = 13), the superior facet of the subjacent vertebra (n = 9), or both (n = 7). Injury of the rotated vertebra was unilateral in 22 patients but bilateral in 18 patients. Facet fractures frequently extended into the ipsilateral lamina or articular pillar or both. An avulsion fracture from the posteroinferior aspect of the rotated vertebral body, indicating disk disruption, occurred in 10 patients (25%), and seven patients (17%) had complete isolation of an articular pillar. Facet fractures were confirmed for 27 patients who underwent surgical stabilization. Neurologic deficits developed in 29 (73%) of the 40 patients and included radiculopathy in 11 patients and cord syndromes in 18 patients. Pure dislocation without a facet fracture was more likely to lead to a cord syndrome (p = .006). Cervical rotational facet injuries are often accompanied by facet fractures and bilateral damage of the rotated vertebra. These injuries contribute to rotational instability and require specific internal fixation based on a precise delineation of all injuries. Facet dislocations without fractures have a significantly higher association with cord syndromes than do rotational facet injuries with fractures. CT, particularly with parasagittal reformations, is valuable in identifying all injuries of the rotated and subjacent vertebrae.
Kim, Hui Taek; Ahn, Tae Young; Jang, Jae Hoon; Kim, Kang Hee; Lee, Sung Jae; Jung, Duk Young
2017-03-01
Three-dimensional (3D) computed tomography imaging is now being used to generate 3D models for planning orthopaedic surgery, but the process remains time consuming and expensive. For chronic radial head dislocation, we have designed a graphic overlay approach that employs selected 3D computer images and widely available software to simplify the process of osteotomy site selection. We studied 5 patients (2 traumatic and 3 congenital) with unilateral radial head dislocation. These patients were treated with surgery based on traditional radiographs, but they also had full sets of 3D CT imaging done both before and after their surgery: these 3D CT images form the basis for this study. From the 3D CT images, each patient generated 3 sets of 3D-printed bone models: 2 copies of the preoperative condition, and 1 copy of the postoperative condition. One set of the preoperative models was then actually osteotomized and fixed in the manner suggested by our graphic technique. Arcs of rotation of the 3 sets of 3D-printed bone models were then compared. Arcs of rotation of the 3 groups of bone models were significantly different, with the models osteotomized accordingly to our graphic technique having the widest arcs. For chronic radial head dislocation, our graphic overlay approach simplifies the selection of the osteotomy site(s). Three-dimensional-printed bone models suggest that this approach could improve range of motion of the forearm in actual surgical practice. Level IV-therapeutic study.
Sex and growth effect on pediatric hip injuries presenting to sports medicine clinic.
Stracciolini, Andrea; Yen, Yi-Meng; d'Hemecourt, Pierre A; Lewis, Cara L; Sugimoto, Dai
2016-07-01
To compare sports-related hip injuries on the basis of sex and age in a cohort of young athletes. A 5% random probability sample of all new patients' charts over a 10-year time period was selected for investigation. The most common hip injury diagnoses, sport at time of injury, mechanism (acute/traumatic vs. overuse), and types (bony vs. soft tissue) were compared by sex and age (preadolescent vs. adolescent). Descriptive and χ-analyses were carried out. The interaction of sex and age with respect to hip injury over time was examined by two-way (sex, age) analysis of variance. A total of 2133 charts were reviewed; N=87 hip injuries. The main diagnoses for males included labral tear (23.1%), avulsion fracture (11.5%), slipped capital femoral epiphysis (11.5%), dislocation (7.7%), and tendonitis (7.7%). The main diagnoses for females were labral tear (59.0%), tendonitis (14.8%), snapping hip syndrome (6.6%), strain (4.9%), and bursitis (4.9%). The five most common sports/activities at the time of hip injury were dancing/ballet (23.0%), soccer (18.4%), gymnastics (9.2%), ice hockey (8.1%), and track and field (6.9%). Age by sex comparisons showed a greater proportion of the total hip injuries (38.5%) in males compared with females (8.2%) during preadolescence (5-12 years). However, in adolescence (13-17 years), the hip injury proportion was significantly higher in females (91.8%) compared with males (61.5%; P<0.001). Injury mechanism and type differed by sex, with females sustaining more chronic/overuse (95.1%) and soft tissue type injuries (93.4%) compared with males (50.0 and 53.8%, respectively; P<0.001). Females were found to have a sharper increase in hip injury proportion as they progressed through puberty compared with males (analysis of variance sex-by-age interaction; P<0.001). Hip injury mechanism and type differed significantly between males and females during growth. Notably, the proportion of hip injuries in the young female athletes showed a significantly greater increase with advancing age compared with males. Hip injuries in children and the interplay with growth, as it relates to injury predisposition, require further investigation to facilitate efforts aimed at prevention. Cross-sectional epidemiological study.
Sex and Growth Effect on Pediatric Hip Injuries Presenting to Sports Medicine Clinic
Stracciolini, Andrea; Yen, Yi-Meng; d'Hemecourt, Pierre A.; Lewis, Cara L.; Sugimoto, Dai
2016-01-01
Background To compare sports-related hip injuries based on sex and age in a cohort of young athletes. Methods 5% random probability sample of all new patients’ charts over a ten-year time period was selected for investigation. The most common hip injury diagnoses, sport at time of injury, mechanism (acute/traumatic versus overuse), and types (bony versus soft tissue) were compared by sex and age (pre-adolescent versus adolescent). Descriptive and chi-square analyzes were performed. The interaction of sex and age with regard to hip injury over time was examined by a two-way (sex, age) analysis of variance (ANOVA). Results 2,133 charts were reviewed; N=87 hip injuries. Leading diagnoses for males included labral tear (23.1%), avulsion fracture (11.5%), slipped capital femoral epiphysis (11.5%), dislocation (7.7%) and tendonitis (7.7%). Leading diagnoses for females were labral tear (59.0%), tendonitis (14.8%), snapping hip syndrome (6.6%), strain (4.9%) and bursitis (4.9%). Five most common sports/activities at time of hip injury were dancing/ballet (23.0%), soccer (18.4%), gymnastics (9.2%), ice hockey (8.1%), and track and fields (6.9%). Growth/maturation by sex showed a greater proportion of the total hip injuries (38.5%) compared to females (8.2%) during pre-adolescence (5-12 years). However, in adolescence (13-17 years), hip injury proportion was significantly greater in females (91.8%), as compared to males (61.5%; P<0.001). Injury mechanism and type differed by sex with females sustaining more chronic/overuse (95.1%) and soft tissue type injuries (93.4%), as compared to males (50.0% and 53.8%, respectively; P<0.001). Females were found to have a sharper increase in hip injury proportion as they progress through puberty as compared to males (ANOVA sex-by-age interaction; P<0.001). Conclusions Hip injury mechanism and type differed significantly between males and females during growth. Notably, the proportion of hip injuries in the young female athletes showed a significantly greater increase with advancing age as compared to males. Hip injuries in children and the interplay with growth, as it relates to injury predisposition, requires further investigation in order to facilitate efforts aimed at prevention. PMID:27058819
2013-01-01
Background Obesity and serum C-reactive protein (CRP) (a sensitive marker of inflammatory activity) are associated with most chronic diseases. Abdominal adiposity along with age is the strongest determinant of baseline CRP levels in healthy subjects. The mechanism of the association of serum CRP with disease is uncertain. We hypothesized that baseline serum CRP is a marker of inflammatory responsiveness to injury and that abdominal adiposity is the main determinant of this responsiveness. We studied the effect of abdominal adiposity, age and other environmental risk factors for chronic disease on the CRP response to a standardised surgical insult, unilateral hernia repair to not only test this hypothesis but to inform the factors which must be taken into account when assessing systemic inflammatory responses to surgery. Methods 102 male subjects aged 24-94 underwent unilateral hernia repair by a single operator. CRP was measured at 0, 6, 24 and 48 hrs. Response was defined as the peak CRP adjusted for baseline CRP. Results Age and waist:hip ratio (WHR) were associated both with basal CRP and CRP response with similar effect sizes after adjustment for a wide-range of covariates. The adjusted proportional difference in CRP response per 10% increase in WHR was 1.50 (1.17-1.91) p = 0.0014 and 1.15(1.00-1.31) p = 0.05 per decade increase in age. There was no evidence of important effects of other environmental cardiovascular risk factors on CRP response. Conclusion Waist:hip ratio and age need to be considered when studying the inflammatory response to surgery. The finding that age and waist:hip ratio influence baseline and post-operative CRP levels to a similar extent suggests that baseline CRP is a measure of inflammatory responsiveness to casual stimuli and that higher age and obesity modulate the generic excitability of the inflammatory system leading to both higher baseline CRP and higher CRP response to surgery. The mechanism for the association of baseline CRP and waist:hip ratio to chronic disease outcomes could be through this increase in inflammatory system excitability. PMID:23391158
Imai, Norio; Ito, Tomoyuki; Suda, Ken; Miyasaka, Dai; Endo, Naoto
2017-07-01
Venous thromboembolism is one of the general complications following total hip arthroplasty, wherein various preventive treatments have been recommended. Several studies reported that venous thromboembolism incidence after total hip arthroplasty was similar in patients who were administered prophylaxis with a conventional mechanical procedure alone, and those who were administered pharmacological anticoagulation therapy. Therefore, the optimum methods of prophylaxis are still controversial. The purpose of this study was to investigate whether manual calf massage and passive ankle motion could lower the risk for venous thromboembolism after total hip arthroplasty. We retrospectively reviewed the data of 126 consecutive patients undergoing elective primary unilateral total hip arthroplasty wherein manual calf massage and passive ankle motion were performed after the surgery at our hospitals between January and October 2014. The 138 patients of the control group underwent total hip arthroplasty using the same surgical approach and pre- and postoperative protocols without this mechanical prophylaxis between January and December 2013. This mechanical prophylaxis was performed simultaneously 30 times during approximately 10 s; these procedures were repeated thrice immediately after total hip arthroplasty. Duplex ultrasonography was performed to observe the veins of both legs in all the patients on postoperative day 7. The incidence of deep vein thrombosis was 6.52% and 0.79% in the control and manual calf massage and passive ankle motion groups, respectively. The odds ratio for the manual calf massage and passive ankle motion groups was 8.72. Performing this mechanical prophylaxis reduced the incidence of venous thromboembolism after total hip arthroplasty. This mechanical prophylaxis is not only simple and easy, but is also safe and inexpensive. We therefore recommend that manual calf massage and passive ankle motion be performed in patients who will undergo total hip arthroplasty, if deep vein thrombosis does not exist before the surgery. Copyright © 2017 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
Schlegelmilch, Michael; Moreau, Barbara; Jarrín, Patricia; Tran, Bach; Chuck, Anderson
2017-01-01
Background Few charitable overseas surgical missions produce cost-effectiveness analyses of their work. Methods We compared the pre- and postoperative health status for 157 total hip arthroplasty (THA) patients operated on from 2007 to 2011 attended by an annual Canadian orthopedic mission to Ecuador to determine the quality-adjusted life years (QALYs) gained. The costs of each mission are known. The cost per surgery was divided by the average lifetime QALYs gained to estimate an incremental cost-effectiveness ratio (ICER) in Canadian dollars per QALY. Results The average lifetime QALYs (95% CI) gained were 1.46 (1.4–1.5), 2.5 (2.4–2.6), and 2.9 (2.7–3.1) for unilateral, bilateral, and staged (two THAs in different years) operations, respectively. The ICERs were $4,442 for unilateral, $2,939 for bilateral, and $4392 for staged procedures. Seventy percent of the mission budget was spent on the transport and accommodation of volunteers. Conclusion THA by a Canadian short-stay surgical team was highly cost-effective, according to criteria from the National Institute for Health and Care Excellence and the World Health Organization. We encourage other international missions to provide similar cost-effectiveness data to enable better comparison between mission types and between mission and nonmission care. PMID:29403664
Canine total hip replacement using a cementless threaded cup and stem: a review of 55 cases.
Denny, H R; Linnell, M; Maddox, T W; Comerford, E J
2018-06-01
To determine the long-term results and complications associated with the Helica ® cementless hip endoprosthesis system. Retrospective study of 55 consecutive Helica total hip replacements performed between January 2010 and February 2015. A total of 55 total hip replacements were performed in 50 dogs; 45 dogs had unilateral hip replacements, and five had staged bilateral replacements. A total of 23 first-generation short femoral stems were implanted in 22 dogs, of which nine cases (39%) experienced complications and 19 (86%) recovered satisfactorily when revisions were included; 31 second-generation femoral stems were implanted in 28 dogs, of which 10 cases (32%) experienced complications, and 26 (93%) made satisfactory recoveries, including revisions. In 36 dogs for which data were available, postoperative Liverpool Osteoarthritis in Dogs scores were significantly reduced compared to preoperative scores. Complications occurred in a total of 19 cases (34·5%; 95% confidence interval: 22 to 47·1%); the most common was aseptic loosening of the femoral stem [11 cases (20%; 95% confidence interval: 9·4 to 30·6%)]. Following multivariable analysis, no risk factors were identified for overall complications, but there was a significant association of implant type (first-generation short stem) with loosening (odds ratio 4·9, 95% confidence interval: 1·1 to 22·1, P=0·034). This study found the Helica hip endoprosthesis system to be effective in the management of hip dysplasia and osteoarthritis in dogs. Aseptic loosening of the femoral stem remains the most common complication but appears to have been significantly reduced with the introduction of the second-generation stem. © 2018 British Small Animal Veterinary Association.
Weber, Alexander E; Kuhns, Benjamin D; Cvetanovich, Gregory L; Lewis, Paul B; Mather, Richard C; Salata, Michael J; Nho, Shane J
2017-01-01
The purpose of this study was to examine the hip capsule in a subset of symptomatic patients who underwent capsular closure during hip arthroscopy. All patients undergoing primary hip arthroscopy for femoroacetabular impingement (FAI) with routine capsular closure between January 1, 2012, and December 31, 2015, were eligible. Only patients with unilateral surgery and a postoperative magnetic resonance imaging (MRI; ordered for persistent symptoms) were included. Four independent reviewers evaluated each hip capsule for thickness and the absence or presence of defects. During the study, 1,463 patients had hip arthroscopy for FAI with routine capsular closure, and 53 (3.6%) underwent a postoperative MRI. Fourteen of the 53 were excluded owing to revision status or additional procedures. The final study population included 39 patients (23 female patients and 16 male patients), with an average patient age of 31.7 ± 11.4 years and an average body mass index of 23.3 ± 2.9. There were 3 (7.5%) capsular defects, and the intraclass correlation coefficient (ICC) was 0.82. The operative hip capsule was significantly thicker in the zone of capsulotomy, and subsequent repair as compared with the unaffected, contralateral hip capsule (5.0 ± 1.2 mm vs 4.6 ± 1.4 mm; P = .02), ICC 0.83. Additionally, males had thicker hip capsules as compared with their female counterparts, on the operative side (5.4 ± 1.1 mm vs 4.5 ± 1.2 mm; P = .02) and the nonoperative side (4.8 ± 1.6 mm vs 4.1 ± 0.9 mm; P = .08). In a subset of symptomatic patients after hip arthroscopy for FAI, the majority (92.5%) of the repaired hip capsules remained closed at greater than 1 year of follow-up. The hip capsule adjacent to the capsulotomy and subsequent repair is thickened compared with the same location on the contralateral, nonoperative hip. Aside from gender, patient-related and FAI-related factors do not correlate with capsular thickness nor do they seem to correlate with the propensity to develop a capsular defect. Level IV, prognostic case series. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Jacobs, Jeremy M.; Evanson, J. Richard; Pniewski, Josh; Dickston, Michelle L.; Mueller, Terry; Bojescul, John A.
2017-01-01
Introduction Hip arthroscopy allows surgeons to address intra-articular pathology of the hip while avoiding more invasive open surgical dislocation. However the post-operative rehabilitation protocols have varied greatly in the literature, with many having prolonged periods of limited motion and weight bearing. Purpose The purpose of this study was to describe a criterion-based early weight bearing protocol following hip arthroscopy and investigate functional outcomes in the subjects who were active duty military. Methods Active duty personnel undergoing hip arthroscopy for symptomatic femoroacetabular impingement were prospectively assessed in a controlled environment for the ability to incorporate early postoperative weight-bearing with the following criteria: no increased pain complaint with weight bearing and normalized gait pattern. Modified Harris Hip (HHS) and Hip Outcome score (HOS) were performed preoperatively and at six months post-op. Participants were progressed with a standard hip arthroscopy protocol. Hip flexion was limited to not exceed 90 degrees for the first three weeks post-op, with progression back to running beginning at three months. Final discharge was dependent upon the ability to run two miles at military specified pace and do a single leg broad jump within six inches of the contralateral leg without an increase in pain. Results Eleven participants met inclusion criteria over the study period. Crutch use was discontinued at an average of five days following surgery based on established weight bearing criteria. Only one participant required continued crutch use at 15 days. Participants’ functional outcome was improved postoperatively, as demonstrated by significant increases in HOS and HHS. At the six month follow up, eight of 11 participants were able to take and complete a full Army Physical Fitness Test. Conclusions Following completion of the early weight bearing rehabilitation protocol, 81% of participants were able to progress to full weight bearing by four days post-operative, with normalized pain-free gait patterns. Active duty personnel utilizing an early weight bearing protocol following hip arthroscopy demonstrated significant functional improvement at six months. Level of Evidence Level 4, Case-series PMID:29181261
Shaw, K Aaron; Jacobs, Jeremy M; Evanson, J Richard; Pniewski, Josh; Dickston, Michelle L; Mueller, Terry; Bojescul, John A
2017-10-01
Hip arthroscopy allows surgeons to address intra-articular pathology of the hip while avoiding more invasive open surgical dislocation. However the post-operative rehabilitation protocols have varied greatly in the literature, with many having prolonged periods of limited motion and weight bearing. The purpose of this study was to describe a criterion-based early weight bearing protocol following hip arthroscopy and investigate functional outcomes in the subjects who were active duty military. Active duty personnel undergoing hip arthroscopy for symptomatic femoroacetabular impingement were prospectively assessed in a controlled environment for the ability to incorporate early postoperative weight-bearing with the following criteria: no increased pain complaint with weight bearing and normalized gait pattern. Modified Harris Hip (HHS) and Hip Outcome score (HOS) were performed preoperatively and at six months post-op. Participants were progressed with a standard hip arthroscopy protocol. Hip flexion was limited to not exceed 90 degrees for the first three weeks post-op, with progression back to running beginning at three months. Final discharge was dependent upon the ability to run two miles at military specified pace and do a single leg broad jump within six inches of the contralateral leg without an increase in pain. Eleven participants met inclusion criteria over the study period. Crutch use was discontinued at an average of five days following surgery based on established weight bearing criteria. Only one participant required continued crutch use at 15 days. Participants' functional outcome was improved postoperatively, as demonstrated by significant increases in HOS and HHS. At the six month follow up, eight of 11 participants were able to take and complete a full Army Physical Fitness Test. Following completion of the early weight bearing rehabilitation protocol, 81% of participants were able to progress to full weight bearing by four days post-operative, with normalized pain-free gait patterns. Active duty personnel utilizing an early weight bearing protocol following hip arthroscopy demonstrated significant functional improvement at six months. Level 4, Case-series.
Wörner, Tobias; Sigurðsson, Haraldur B; Pålsson, Anders; Kostogiannis, Ioannis; Ageberg, Eva
2017-01-01
This study aimed to evaluate patient-reported outcomes as well as lower extremity and trunk muscle function in patients with long-standing hip and groin pain, in comparison with matched, healthy controls. It was hypothesized that patients with long-standing hip and groin pain would report more deficiency on the Copenhagen Hip and Groin Outcome Score (HAGOS) and have worse outcomes on performance-based measures than healthy controls. Nineteen patients with long-standing hip and groin pain and 19 healthy, activity level-, age-, gender-, and weight-matched controls were assessed with the HAGOS for self-reported outcomes, and a parallel squat (w/kg), single-leg triple jump (cm), single-leg rise (n), barbell roll-out (% of height), and plank test (s) for performance-based measures. Independent sample t test was performed to assess between-group differences. The paired t test was used to analyse between-limb differences in unilateral performance tasks. The patients had worse scores than the controls in all HAGOS subscales (p ≤ 0.001), while no statistically significant differences were observed for any performance measure between groups or between symptomatic and non-symptomatic limbs. Despite significant self-reported functional limitations on the HAGOS, there were no significant differences between groups in performance-based strength or power measures. The results of this study highlight the need to identify performance-based measures, sensitive to functional deficiencies in patients with long-standing hip and groin pain in order to complement the clinical picture obtained by patient-reported outcomes such as the HAGOS. III.
In vivo implant fixation of carbon fiber-reinforced PEEK hip prostheses in an ovine model.
Nakahara, Ichiro; Takao, Masaki; Bandoh, Shunichi; Bertollo, Nicky; Walsh, William R; Sugano, Nobuhiko
2013-03-01
Carbon fiber-reinforced polyetheretherketone (CFR/PEEK) is theoretically suitable as a material for use in hip prostheses, offering excellent biocompatibility, mechanical properties, and the absence of metal ions. To evaluate in vivo fixation methods of CFR/PEEK hip prostheses in bone, we examined radiographic and histological results for cementless or cemented CFR/PEEK hip prostheses in an ovine model with implantation up to 52 weeks. CFR/PEEK cups and stems with rough-textured surfaces plus hydroxyapatite (HA) coatings for cementless fixation and CFR/PEEK cups and stems without HA coating for cement fixation were manufactured based on ovine computed tomography (CT) data. Unilateral total hip arthroplasty was performed using cementless or cemented CFR/PEEK hip prostheses. Five cementless cups and stems and six cemented cups and stems were evaluated. On the femoral side, all cementless stems demonstrated bony ongrowth fixation and all cemented stems demonstrated stable fixation without any gaps at both the bone-cement and cement-stem interfaces. All cementless cases and four of the six cemented cases showed minimal stress shielding. On the acetabular side, two of the five cementless cups demonstrated bony ongrowth fixation. Our results suggest that both cementless and cemented CFR/PEEK stems work well for fixation. Cup fixation may be difficult for both cementless and cemented types in this ovine model, but bone ongrowth fixation on the cup was first seen in two cementless cases. Cementless fixation can be achieved using HA-coated CFR/PEEK implants, even under load-bearing conditions. Copyright © 2012 Orthopaedic Research Society.
Efficacy of Multimodal Pain Control Protocol in the Setting of Total Hip Arthroplasty
Lee, Kyung-Jae; Bae, Ki-Cheor; Cho, Chul-Hyun; Kwon, Doo-Hyun
2009-01-01
Background This study evaluated the benefits and safety of a multimodal pain control protocol, which included a periarticular injection of local anesthetics, in patients undergoing total hip arthroplasty. Methods Between March 2006 and March 2007, 60 patients undergoing unilateral total hip arthroplasty were randomized to undergo either a multimodal pain control protocol or a conventional pain control protocol. The following parameters were compared: the preoperative and postoperative visual analogue scales (VAS), hospital stay, operative time, postoperative rehabilitation, additional painkiller consumption, and complication rates. Results There was no difference between the groups in terms of diagnosis, age, gender, and BMI. Although both groups had similar VAS scores in the preoperative period and on the fifth postoperative day, there was a significant difference between the groups over the four-day period after surgery. There were no differences in the hospital stay, operative time, additional painkiller consumption, or complication rate between the groups. The average time for comfortable crutch ambulation was 2.8 days in the multimodal pain control protocol group and 5.3 days in the control group. Conclusions The multimodal pain control protocol can significantly reduce the level of postoperative pain and improve patients' satisfaction, with no apparent risks, after total hip arthroplasty. PMID:19885051
Motion of the center of gravity of the body in clinical evaluation of gait.
Tesio, L; Civaschi, P; Tessari, L
1985-04-01
The motion of the center of gravity during walking was analyzed in five hemiplegic subjects and eleven subjects affected by unilateral hip arthritis. In the hemiplegic subjects and 6 subjects with hip arthritis the transfer between kinetic and potential energy (with a passive pendular motion) was found to be 9-95% greater during the step performed on the affected limb ("pathological" step); as a consequence, the muscular work done during this step was 7-81% of the work done during the step performed on the second limb ("normal" step). Qualitatively similar gait anomalies were recorded in all hemiplegic subjects with hypertonus of the paretic limb: these subjects had to lift the spastic limb as a whole during the normal step, with the consequence that the center of gravity was lifted 0.6-3 cm more than during the pathological step. In contrast, various motor patterns were found in patients with hip arthritis. During the pathological step the center of gravity reached a height 0.5-3 cm greater in 7 subjects, 1 cm smaller in one subject, and about the same height reached during the normal step in 3 subjects. This was consistent with the various motor deficits caused by hip arthritis.
Serum Metal Ion Levels Following Total Hip Arthroplasty With Modular Dual Mobility Components.
Matsen Ko, Laura J; Pollag, Kimberley E; Yoo, Joanne Y; Sharkey, Peter F
2016-01-01
Dual mobility acetabular components can reduce the incidence of total hip arthroplasty (THA) instability. Modular dual mobility (MDM) components facilitate acetabular component implantation. However, corrosion can occur at modular junctions. Serum cobalt and chromium levels and Oxford scores were obtained at minimum two year follow-up for 100 consecutive patients who had THA with MDM components. Average Oxford score was 43 (range 13-48). Average serum cobalt and chromium values were 0.7 mcg/L (range, 0.0 to 7.0) and 0.6 mcg/L (range, 0.1 to 2.7), respectively. MARS MRI was performed for four patients with pain and elevated serum cobalt levels. Two of these studies were consistent with adverse local tissue reaction. We recommend use of MDM implants in only patients at high risk for dislocation following THA. Copyright © 2016 Elsevier Inc. All rights reserved.
Wenger, Daniel; Samuelsson, Hanna; Düppe, Henrik; Tiderius, Carl Johan
2016-01-01
Background and purpose — Avascular necrosis of the femoral head (AVN) is a complication in treatment of developmental dysplasia of the hip (DDH). We evaluated the risk of AVN after early treatment in the von Rosen splint and measured the diameter of the ossific nucleus at 1 year of age. Children and methods — All children born in Malmö, Sweden, undergo clinical screening for neonatal instability of the hip (NIH). We reviewed 1-year radiographs of all children treated early for NIH in our department from 2003 through 2010. The diameter of the ossific nucleus was measured, and signs of AVN were classified according to Kalamchi-MacEwen. Subsequent radiographs, taken for any reason, were reviewed and a local registry of diagnoses was used to identify subsequent AVN. Results — 229 of 586 children referred because of suspected NIH received early treatment (age ≤ 1 week) for NIH during the study period. 2 of the 229 treated children (0.9%, 95% CI: 0.1–3.1) had grade-1 AVN. Both had spontaneous resolution and were asymptomatic during the observation time (6 and 8 years). 466 children met the inclusion criteria for measurement of the ossific nucleus. Neonatally dislocated hips had significantly smaller ossific nuclei than neonatally stable hips: mean 9.4 mm (95% CI: 9.1–9.8) vs. 11.1 mm (95% CI: 10.9–11.3) at 1 year (p < 0.001). Interpretation — Early treatment with the von Rosen splint for NIH is safe regarding AVN. The ossification of the femoral head is slower in children with NIH than in untreated children with neonatally stable hips. PMID:26730503
Thirteen-year outcomes in the Anatomique Benoist Girard II hip prosthesis.
Catanach, Michael J M; Sorial, Rami M; Eslick, Guy D
2015-04-01
The Stryker Anatomique Benoist Girard (ABG) hip implant system was a commonly used cementless prosthesis in the early 2000s, which fell from favour after several studies emerged implicating the prosthesis in high rates of revision. This retrospective, single-surgeon clinical study examines the fracture rate, revision rate and reasons for revision in 500 consecutive ABG II primary total conventional hip replacements. Follow-up was conducted by audit of patient notes, patient mailout survey, patient phone contact and audit of the Australian National Joint Replacement Registry (NJRR) database to find instances of fracture and revision. End points were periprosthetic fracture and revision for any reason. Follow-up was 1.2-13.8 years with a mean of 6.58 years. Of the 500 hips, 17 (3.4%) had undergone a revision. Of these, 13 were due to periprosthetic fracture. Four further fractures occurred that were not revised. Eight of these periprosthetic fractures occurred within 1 year post-operatively. There were four revisions for recurrent dislocations. Kaplan-Meier survival curve demonstrates a 93.7% survivorship at 6.58 years for revision for any reason. Multivariate analysis showed the only statistically significant factor for increased risk of revision was smaller stem size. Our results were consistent with the literature in that the ABG II system has good medium-term results but is prone to periprosthetic fractures, especially in the early post-operative period. When used as a primary total hip arthroplasty, the ABG II system has an 8-year revision rate of 5.6% compared with the 4.9% of all primary total hip arthroplasties. © 2014 Royal Australasian College of Surgeons.
Effect of Body Mass Index on Complications and Reoperations After Total Hip Arthroplasty.
Wagner, Eric R; Kamath, Atul F; Fruth, Kristin M; Harmsen, William S; Berry, Daniel J
2016-02-03
High body mass index (BMI) is associated with increased rates of complications after total hip arthroplasty. Studies to date have evaluated risk mainly as a dichotomous variable according to BMI thresholds. The purpose of this paper was to characterize the risk of complications and implant survival according to BMI as a continuous variable. Using prospectively collected data from our institutional total joint registry, we analyzed 21,361 consecutive hips (17,774 patients) treated with primary total hip arthroplasty between 1985 and 2012 at a single institution. The average BMI at the time of surgery was 28.7 kg/m(2) (range, 15 to 69 kg/m(2)). Estimates of revision surgery and common complications associated with BMI were analyzed using the Kaplan-Meier method of assessing survivorship, with associations of outcomes assessed using a Cox model. Utilizing smoothing spline parameterization, we found that reoperation (p < 0.001) and implant revision or removal rates (p = 0.002) increased with increasing BMI. Increasing BMI was associated with increased rates of early hip dislocation (p = 0.02), wound infection, and, most strikingly, deep periprosthetic infection (a hazard ratio of 1.09 per unit of BMI >25 kg/m(2); p < 0.001). However, we found no association between increasing BMI and any revision for mechanical failure of the implant or between increasing BMI and revision for aseptic implant loosening. There was an inverse correlation between increasing BMI and risk of revision for bearing wear. The rates of reoperation, implant revision or removal, and common complications after total hip arthroplasty were strongly associated with BMI. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.
Tuberculosis of the hip in children: A retrospective analysis of 27 patients.
Agarwal, Anil; Suri, Tarun; Verma, Indereshwar; Kumar, Shashi Kant; Gupta, Neeraj; Shaharyar, Abbas
2014-09-01
We retrospectively evaluated the pretreatment radiological presentation and the clinicoradiological outcome at the completion of 1 year chemotherapy in osteoarticular tuberculosis of hip in children to prognosticate correlation between them. We retrospectively analyzed the clinical and plain radiographic findings in 27 patients with an age of 12 years or younger in whom hip tuberculosis was diagnosed and treated between 2006 and 2010. The diagnosis was based on histopathology in 14 and clinicoradiological basis in 13 patients. The pre and post treatment plain radiographs were evaluated according to Shanmugasundaram radiological classification and our observations regarding unclassified cases which were not fit in this classification were suggested. The functional outcome at the completion of chemotherapy was assessed using modified Moon's criteria. The male female ratio was 11:16. The left hip was involved more frequently than the right (17:10). The average age was 7.37 years (range, 2-12 years). In the pretreatment radiographs, 9 hips were normal, 6 traveling, 4 dislocating, 1 protrusio acetabuli, 3 atrophic and 4 unclassified types (3 triradiate; 1 pseudarthrosis coxae). There were no Perthes and mortar pestle at the initial presentation. Posttreatment, the types changed to 9 normal, 3 Perthes, 1 protrusio acetabuli, 1 atrophic, 4 mortar pestle and 9 unclassified types (3 triradiate, 3 pseudarthrosis coxae and 3 ankylosed). There were 37% excellent, 18.5% good, 26% fair and 18.5% poor results. The prognosis was best with initial "triradiate" and normal types and worst with posttreatment atrophic and "ankylosed" types. The Shanmugasundaram radiological types accurately predict prognosis only in normal types and "triradiate" pattern. The functional outcome is independent of radiological morphology of the hip in smaller children.
Tuberculosis of the hip in children: A retrospective analysis of 27 patients
Agarwal, Anil; Suri, Tarun; Verma, Indereshwar; Kumar, Shashi Kant; Gupta, Neeraj; Shaharyar, Abbas
2014-01-01
Background: We retrospectively evaluated the pretreatment radiological presentation and the clinicoradiological outcome at the completion of 1 year chemotherapy in osteoarticular tuberculosis of hip in children to prognosticate correlation between them. Materials and Methods: We retrospectively analyzed the clinical and plain radiographic findings in 27 patients with an age of 12 years or younger in whom hip tuberculosis was diagnosed and treated between 2006 and 2010. The diagnosis was based on histopathology in 14 and clinicoradiological basis in 13 patients. The pre and post treatment plain radiographs were evaluated according to Shanmugasundaram radiological classification and our observations regarding unclassified cases which were not fit in this classification were suggested. The functional outcome at the completion of chemotherapy was assessed using modified Moon's criteria. Results: The male female ratio was 11:16. The left hip was involved more frequently than the right (17:10). The average age was 7.37 years (range, 2-12 years). In the pretreatment radiographs, 9 hips were normal, 6 traveling, 4 dislocating, 1 protrusio acetabuli, 3 atrophic and 4 unclassified types (3 triradiate; 1 pseudarthrosis coxae). There were no Perthes and mortar pestle at the initial presentation. Posttreatment, the types changed to 9 normal, 3 Perthes, 1 protrusio acetabuli, 1 atrophic, 4 mortar pestle and 9 unclassified types (3 triradiate, 3 pseudarthrosis coxae and 3 ankylosed). There were 37% excellent, 18.5% good, 26% fair and 18.5% poor results. The prognosis was best with initial “triradiate” and normal types and worst with posttreatment atrophic and “ankylosed” types. Conclusions: The Shanmugasundaram radiological types accurately predict prognosis only in normal types and “triradiate” pattern. The functional outcome is independent of radiological morphology of the hip in smaller children. PMID:25298552
The Epidemiology and Demographics of Hip Dysplasia
Loder, Randall T.; Skopelja, Elaine N.
2011-01-01
The etiology of developmental dysplasia of the hip (DDH) is unknown. There are many insights, however, from epidemiologic/demographic information. A systematic medical literature review regarding DDH was performed. There is a predominance of left-sided (64.0%) and unilateral disease (63.4%). The incidence per 1000 live births ranges from 0.06 in Africans in Africa to 76.1 in Native Americans. There is significant variability in incidence within each racial group by geographic location. The incidence of clinical neonatal hip instability at birth ranges from 0.4 in Africans to 61.7 in Polish Caucasians. Predictors of DDH are breech presentation, positive family history, and gender (female). Children born premature, with low birth weights, or to multifetal pregnancies are somewhat protected from DDH. Certain HLA A, B, and D types demonstrate an increase in DDH. Chromosome 17q21 is strongly associated with DDH. Ligamentous laxity and abnormalities in collagen metabolism, estrogen metabolism, and pregnancy-associated pelvic instability are well-described associations with DDH. Many studies demonstrate an increase of DDH in the winter, both in the northern and southern hemispheres. Swaddling is strongly associated with DDH. Amniocentesis, premature labor, and massive radiation exposure may increase the risk of DDH. Associated conditions are congenital muscular torticollis and congenital foot deformities. The opposite hip is frequently abnormal when using rigorous radiographic assessments. The role of acetabular dysplasia and adult hip osteoarthritis is complex. Archeological studies demonstrate that the epidemiology of DDH may be changing. PMID:24977057
Koelewijn, Anne D; van den Bogert, Antonie J
2016-09-01
Despite having a fully functional knee and hip in both legs, asymmetries in joint moments of the knee and hip are often seen in gait of persons with a unilateral transtibial amputation (TTA), possibly resulting in excessive joint loading. We hypothesize that persons with a TTA can walk with more symmetric joint moments at the cost of increased effort or abnormal kinematics. The hypothesis was tested using predictive simulations of gait. Open loop controls of one gait cycle were found by solving an optimization problem that minimizes a combination of walking effort and tracking error in joint angles, ground reaction force and gait cycle duration. A second objective was added to penalize joint moment asymmetry, creating a multi-objective optimization problem. A Pareto front was constructed by changing the weights of the objectives and three solutions were analyzed to study the effect of increasing joint moment symmetry. When the optimization placed more weight on moment symmetry, walking effort increased and kinematics became less normal, confirming the hypothesis. TTA gait improved with a moderate increase in joint moment symmetry. At a small cost of effort and abnormal kinematics, the peak hip extension moment in the intact leg was decreased significantly, and so was the joint contact force in the knee and hip. Additional symmetry required a significant increase in walking effort and the joint contact forces in both hips became significantly higher than in able-bodied gait. Copyright © 2016 Elsevier B.V. All rights reserved.
Vijapura, Anita; Levine, Harlan B; Donato, Michele; Hartzband, Mark A; Baker, Melissa; Klein, Gregg R
2018-03-01
The immunosuppressive regimens required for hematopoietic stem cell transplantation predispose recipients to complications, including avascular necrosis. Cancer-related comorbidities, immunosuppression, and poor bone quality theoretically increase the risk for perioperative medical complications, infection, and implant-related complications in total joint arthroplasty. This study reviewed 20 primary total hip arthroplasties for avascular necrosis in 14 patients. Outcomes were assessed at routine clinical visits and Harris hip scores were calculated. Follow-up radiographs were evaluated for component malposition, loosening, polyethylene wear, and osteolysis. Average follow-up was 44.5 months for all patients. Postoperative clinical follow-up revealed good to excellent outcomes, with significant improvement in functional outcome scores. There were no periprosthetic infections or revisions for aseptic loosening. There was 1 dislocation on postoperative day 40, which was treated successfully with a closed reduction. Two patients with a prior history of venous thromboembolism developed a pulmonary embolus on postoperative day 13 and 77, respectively. Four patients died several months to years after arthroplasty of complications unrelated to the surgical procedure. Total hip arthroplasty can both be safely performed and greatly improve quality of life in recipients of hematopoietic stem cell transplantation who develop avascular necrosis. However, prolonged venous thromboembolism prophylaxis should be carefully considered in this high-risk patient population. [Orthopedics. 2018; 41(2):e257-e261.]. Copyright 2018, SLACK Incorporated.
Schmitt, Jürgen W; Benden, Christian; Dora, Claudio; Werner, Clément M L
2016-01-01
In recent years, the number of lung transplants has increased rapidly, with higher quality of life and improved survival rates in transplant recipients, including patients with advanced age. This, in turn, means that more transplant recipients will seek musculoskeletal care to treat degenerative joint disease and also trauma incidents. Safety concerns regarding elective and posttraumatic hip arthroplasty in transplant patients include an increased risk of infection, wound healing problems, periprosthetic fractures and loosening of the implants. Clinical outcomes and safety aspects were retrospectively reviewed for five primary total hip arthroplasties (THA) in lung transplant recipients with minimal follow-up of two years at average of 2.6 (2-11) years. Patients were recruited from the Zurich Lung Transplant Center comprising of a cohort of 253 patients between January 1st, 2004 and December 31st, 2013. All five patients subjectively reported excellent outcomes after THA with a final average Harris Hip Score of 97 (86-100). One 71-year-old patient died 26 months after THA unrelated to arthroplasty. One superficial wound healing disturbance was documented. No periprosthetic fractures, no dislocations, no periprosthetic infections, no further revision surgery, no implant loosening was observed. In conclusion, THA can be safely and successfully performed even in lung transplant patients under long-term immunosuppressive therapy and polymedication, provided a multidisciplinary approach can be granted.
Ozan, Fırat; Koyuncu, Şemmi; Pekedis, Mahmut; Altay, Taşkın; Yıldız, Hasan; Toker, Gökhan
2014-01-01
The aim of the study was to investigate the efficacy of greater trochanteric fixation using a multifilament cable to ensure abductor lever arm continuity in patients with a proximal femoral fracture undergoing partial hip arthroplasty. Mean age of the patients (12 men, 20 women) was 84.12 years. Mean follow-up was 13.06 months. Fixation of the dislocated greater trochanter with or without a cable following load application was assessed by finite element analysis (FEA). Radiological evaluation was based on the distance between the fracture and the union site. Harris hip score was used to evaluate final results: outcomes were excellent in 7 patients (21.8%), good in 17 patients (53.1%), average in 5 patients (15.6%), and poor in 1 patient (9.3%). Mean abduction angle was 20.21°. Union was achieved in 14 patients (43.7%), fibrous union in 12 (37.5%), and no union in 6 (18.7%). FEA showed that the maximum total displacement of the greater trochanter decreased when the fractured bone was fixed with a cable. As the force applied to the cable increased, the displacement of the fractured trochanter decreased. This technique ensures continuity of the abductor lever arm in patients with a proximal femoral fracture who are undergoing partial hip arthroplasty surgery. PMID:25177703
Similar range of motion and function after resurfacing large–head or standard total hip arthroplasty
2013-01-01
Background and purpose Large–size hip articulations may improve range of motion (ROM) and function compared to a 28–mm THA, and the low risk of dislocation allows the patients more activity postoperatively. On the other hand, the greater extent of surgery for resurfacing hip arthroplasty (RHA) could impair rehabilitation. We investigated the effect of head size and surgical procedure on postoperative rehabilitation in a randomized clinical trial (RCT). Methods We followed randomized groups of RHAs, large–head THAs and standard THAs at 2 months, 6 months, 1 and 2 years postoperatively, recording clinical rehabilitation parameters. Results Large articulations increased the mean total range of motion by 13° during the first 6 postoperative months. The increase was not statistically significant and was transient. The 2–year total ROM (SD) for RHA, standard THA, and large–head THA was 221° (35), 232° (36), and 225° (30) respectively, but the differences were not statistically significant. The 3 groups were similar regarding Harris hip score, UCLA activity score, step rate, and sick leave. Interpretation Head size had no influence on range of motion. The lack of restriction allowed for large articulations did not improve the clinical and patient–perceived outcomes. The more extensive surgical procedure of RHA did not impair the rehabilitation. This project is registered at ClinicalTrials.gov under # NCT01113762. PMID:23530872
Outcomes of total hip arthroplasty: a study of patients one year postsurgery.
Trudelle-Jackson, Elaine; Emerson, Roger; Smith, Sue
2002-06-01
Ex post facto research using prospective analysis of differences between the involved hip and uninvolved hip. To assess outcomes of total hip arthroplasty (THA) by comparing range of motion (ROM), muscle strength, and postural stability in the surgical hip to those of the uninvolved hip 1 year postsurgery. An additional objective was to assess degree of relationship among ROM, strength, and postural stability impairments to a measure of self-assessed function. Most patients who have THA receive physical therapy that consists mainly of self-care instructions and an exercise protocol that emphasizes mobility during the acute phase of recovery. But, outcomes of THA 1 year postsurgery indicate that current physical therapy programs used during the acute phase of recovery do not effectively restore physical and functional performance. Subjects consisted of 11 women and 4 men (mean age +/- standard deviation = 62 +/- 8 years) with unilateral THA performed 1 year prior to data collection. Assessment variables consisted of self-assessment of function and measures of postural stability, muscle strength, and hip ROM. The 12-Item Hip Questionnaire was used for self-assessment of function. Three separate repeated measures MANOVA were used to compare the involved side to the uninvolved side in measures of postural stability, strength, and ROM. The Spearman's rho was used to assess degree of association between the subjects' score of self-assessed function and impairments in strength and postural stability. Measures of postural stability were significantly lower (P < or = 0.01) on the side of the replaced hip. Differences in strength values between the involved and uninvolved sides were not statistically significant. Correlations between scores of self-assessed function and hip abductor and knee extensor strength were statistically significant (r = 0.56, P < or = 0.03). Self-assessed function was not significantly correlated to postural stability impairments. The brief postsurgical rehabilitation program received by patients with THA may not be sufficient. A second phase of rehabilitation implemented 4 months or more after surgery that emphasizes weight bearing and postural stability may be advisable.
Cho, Myung-Rae; Lee, Young Sik; Choi, Won-Kee
2018-03-01
The objective was to evaluate the relationship between side-to-side differences of lateral femoral bowing and varus knee deformity based on two-dimensional (2D) assessment in unilateral total knee arthroplasty (TKA). A total of 143 patients with varus knee osteoarthritis who underwent unilateral TKA were enrolled. We evaluated the side-to-side differences of the frontal lower limb alignment by assessing lateral femoral bowing, anatomical medial distal femoral angle, and anatomical medial proximal tibial angle (aMPTA). The average values of all anatomical indices were significantly different between the operated side and the non-operated side (p<0.05). The side-to-side difference in hip knee ankle (HKA) angle had a statistically significant correlation with that in lateral femoral bowing (intraclass correlation coefficient, 0.259; p=0.002) and that in aMPTA. Linear regression analysis showed 0.199° of side-to-side difference in lateral femoral bowing was associated with 1° of side-to-side difference in bilateral HKA angle. The side-to-side difference in lateral femoral bowing showed a tendency to increase in proportion to varus knee deformity based on 2D assessment in unilateral TKA patients.
Zhang, Zhan-feng; Min, Ji-kang; Zhong, Jian-ming; Wang, Dan
2016-06-01
To explore mid-term follow up results of distal fixation prosthesis in treating unstable intertrochanteric fractures in elderly patients. From May 2008 to March 2014,58 elderly patients with unstable intertrochanteric were treated with distal fixation prosthesis, among them, there were 15 males and 43 females aged from 75 to 87 years old with an average of 83.2 years old. Fracture were classified according to Evans classification, 39 cases were type I c and 19 cases were type I d. Surgical risk was evaluated before operation, 9 patients were performed total hip arthroplasty and 49 patients were performed prosthetic replacement hip joint function of patients with different age period, Evans classificaton, prothesis type, fixation method were evaluated respectively by using Harris score. Fifty-six patients were followed up from 13 to 36 months with an average of 21.6 months. Harris score was 83.51 ± 6.40, 5 cases got excellent results, 38 cases good and 13 cases moderate. Harris score of patients aged from 75 to 80 years old was 88.64 ± 2.35, 81.64 ± 6.40 in patients aged more than 80 years old, and had significant differences between two groups; Harris score in patients with type Evans I c was 83.64 ± 6.53, and 83.11 ± 6.08 in type Evans I d, while there was no significant differences between two groups. There was no obvious meaning in Harris score between patients with tension band (83.63 ± 6.15) and without tension band (82.41 ± 6.57). There was no significant meaning in Harris score between patients with normal distal fixation prosthesis (83.34 ± 6.43) and femoral moment reconstruction distal fixation prosthesis (83.92 ± 6.51). There was 1 patient occurred hip joint dislocation on the operative side and re-dislocation after manual reduction, then received open reduction. Two patients occurred femoral osteolysis without clinical symptoms, and treated conservative treatment. Artificial joint replacement for unstable intertrochanteric fractures in elderly patients, hip joint function in patients aged more than 80 years old is worse, while there was no obvious market effect in fracture classification, whether to use tension band and type of distal fixation prosthesis, moreover, proximal femoral osteolysis should be focused on.
Adventure sports and sexual freedom hip replacement: the tripolar hip.
Pritchett, James W
2018-01-01
Certain athletic activities and lifestyles require a completely stable and very mobile hip. Total hip replacement with a natural femoral head size and two mobile-bearing surfaces (i.e., a "tripolar" prosthesis) is the most stable prosthesis. Elegant design and wear-resistant bearing surfaces are the keys to long-term implant survivorship. The hypothesis is that a ceramic-coated tripolar prosthesis using highly cross-linked polyethylene can provide full function and complete stability with low wear. This study sought to determine: (1) patient-reported outcomes, (2) functional outcomes, (3) implant survivorship and complications, and (4) postoperative sexual limitations. Between 1998 and 2011, the author performed 160 primary total hip replacements using tripolar prostheses in patients participating in adventure sports and other physically demanding activities. The institutional review board approved this study. The inclusion criteria were patients who needed unrestricted activity and who were not candidates for or did not choose hip resurfacing. Patients were followed every second year and assessed with radiographs, Harris Hip Score, WOMAC, SF-12, and UCLA functional outcome scores. Patients were asked about symptoms of instability and satisfaction with their hip replacement. Patients were asked both preoperatively and 2 years postoperatively four questions about their sexual activity. Mean follow-up was 11 years. At 2 years' postoperatively, 98% of patients reported their satisfaction as excellent or good and 99% were not limited for sexual activity following surgery. Seventy-four percent of patients reported they were recovered within 6 weeks of surgery. There were no dislocations. There were three revision procedures for implant loosening, infection, and periprosthetic fracture, but there were no failures of the tripolar articulation. The mean postoperative UCLA score was the highly athletic score of 8. There were no signs of osteolysis, wear, or metal sensitivity reactions. The range of motion achieved, sexual, and functional outcomes were higher than with other types of total hip replacement. This ceramic-coated tripolar prosthesis using highly cross-linked polyethylene provides full function, complete stability, and low wear to younger, active patients, thus confirming the hypothesis and clinical relevance.
Does Participation in Sports Affect Osteoarthritic Progression After Periacetabular Osteotomy?
Hara, Daisuke; Hamai, Satoshi; Fukushi, Jun-Ichi; Kawaguchi, Ken-Ichi; Motomura, Goro; Ikemura, Satoshi; Komiyama, Keisuke; Nakashima, Yasuharu
2017-09-01
Periacetabular osteotomy (PAO) is an effective treatment for symptomatic acetabular dysplasia. However, whether postoperative participation in sports leads to progression of the Kellgren-Lawrence (KL) grade of osteoarthritis (OA) in these patients is unclear. To investigate (1) participation in sports before and after PAO and (2) whether postoperative participation in sports leads to progression of the KL grade. Case-control study; Level of evidence, 3. The authors retrospectively reviewed data on 161 patients (183 hips) who underwent PAO for symptomatic acetabular dysplasia with preoperative KL grade 1 or 2 between 1998 and 2011. The mean age at the time of surgery was 42.0 ± 10.9 years (range, 12-64 years), and the mean follow-up duration was 100 months (range, 13-180 months). Data included participation in sports, the University of California, Los Angeles (UCLA) activity scale score, age at the time of surgery, body mass index, follow-up duration, history of treatment for developmental hip dislocations, Merle d'Aubigné-Postel score, Oxford Hip Score, center-edge angle, and KL grade. Univariate and multivariate analyses were applied to determine which factors were associated with progression to KL grade 3 or 4 after PAO. The number of patients who participated in sports significantly increased from 50 (31.1%) preoperatively to 89 (55.3%) postoperatively. The mean UCLA score significantly increased from 4.7 ± 2.1 preoperatively to 5.5 ± 2.0 postoperatively. The KL grade progressed to grade 3 or 4 in 16 hips, including 4 hips that underwent conversion to total hip arthroplasty. No significant differences were found in postoperative participation in sports (89 hips [53.3%] vs 11 hips [68.8%], respectively; P = .24) and the UCLA score (5.6 ± 2.0 vs 5.1 ± 2.0, respectively; P = .30) between hips with KL grade 1 or 2 and KL grade 3 or 4. A multivariate analysis revealed that no factors, including postoperative participation in sports, were significantly associated with progression to KL grade 3 or 4. Postoperative participation in sports after PAO did not significantly and negatively influence progression of the KL grade at midterm follow-up.
[Larsen syndrome: two reports of cases with spinal cord compromise].
Martín Fernández-Mayoralas, D; Fernández-Jaén, A; Muñoz-Jareño, N; Calleja-Pérez, B; San Antonio-Arce, V; Martínez-Boniche, H
Larsen syndrome is characterised by untreatable congenital dislocation of multiple body joints, along with marked foot deformities. These patients have a flattened face with a short nose, a broad depressed nasal bridge and a prominent forehead. In this clinical note our aim is to report two cases that coursed with spinal cord compromise. Case 1: an 18-month-old female with congenital dislocation of knees and hips. The patient had a flat face, sunken root of nose, and carp mouth. Magnetic resonance imaging of the spine showed severe cervical kyphosis secondary to malformation and hypoplasia of the cervical vertebral bodies and important compression of the spinal cord. Clinically, there were also signs of upper motor neuron syndrome, which was especially prominent in the lower limbs. Case 2: a 14-year-old male with a characteristic face and dislocation of the head of the radius. The patient presented amyotrophy of the muscles in the right hand and clinical signs of lower motor neuron syndrome due to neuronal damage secondary to spinal malformations. Larsen syndrome is an infrequent osteochondrodysplasia. Alteration of the spine is common and may give rise to spinal cord compression with varying clinical repercussions which require surgical treatment in the early years of the patient's life.
Ellenbecker, Todd S; Ellenbecker, Gail A; Roetert, E Paul; Silva, Rogerio Teixeira; Keuter, Greg; Sperling, Fabio
2007-08-01
Repetitive loading to the hip joint in athletes has been reported as a factor in the development of degenerative joint disease and intra-articular injury. Little information is available on the bilateral symmetry of hip rotational measures in unilaterally dominant upper extremity athletes. Side-to-side differences in hip joint range of motion may be present because of asymmetrical loading in the lower extremities of elite tennis players and professional baseball pitchers. Cohort (cross-sectional) study (prevalence); Level of evidence, 1. Descriptive measures of hip internal and external rotation active range of motion were taken in the prone position of 64 male and 83 female elite tennis players and 101 male professional baseball pitchers using digital photos and computerized angle calculation software. Bilateral differences in active range of motion between the dominant and nondominant hip were compared using paired t tests and Bonferroni correction for hip internal, external, and total rotation range of motion. A Pearson correlation test was used to test the relationship between years of competition and hip rotation active range of motion. No significant bilateral difference (P > .005) was measured for mean hip internal or external rotation for the elite tennis players or the professional baseball pitchers. An analysis of the number of subjects in each group with a bilateral difference in hip rotation greater than 10 degrees identified 17% of the professional baseball pitchers with internal rotation differences and 42% with external rotation differences. Differences in the elite male tennis players occurred in only 15% of the players for internal rotation and 9% in external rotation. Female subjects had differences in 8% and 12% of the players for internal and external rotation, respectively. Statistical differences were found between the mean total arc of hip range of internal and external rotation in the elite tennis players with the dominant side being greater by a clinically insignificant mean value of 2.5 degrees. Significantly less (P < .005) dominant hip internal rotation and less dominant and nondominant hip total rotation range of motion were found in the professional baseball pitchers compared with the elite male tennis players. This study established typical range of motion patterns and identified bilaterally symmetric hip active range of motion rotation values in elite tennis players and professional baseball pitchers. Asymmetric hip joint rotational active range of motion encountered during clinical examination and screening may indicate abnormalities and would indicate the application of flexibility training, rehabilitation, and further evaluation.
Rapid rehabilitation and recovery with minimally invasive total hip arthroplasty.
Berger, Richard A; Jacobs, Joshua J; Meneghini, R Michael; Della Valle, Craig; Paprosky, Wayne; Rosenberg, Aaron G
2004-12-01
To assess the potential recovery rate of a minimally invasive total hip replacement technique with minimal soft tissue disruption, an accelerated rehabilitation protocol was implemented with weightbearing as tolerated on the day of surgery. One hundred consecutive patients were enrolled in this prospective study. Ninety-seven patients (97%) met all the inpatient physical therapy goals required for discharge to home on the day of surgery; 100% of patients achieved these goals within 23 hours of surgery. Outpatient therapy was initiated in 9% of patients immediately, 62% of patients by 1 week, and all patients by 2 weeks. The mean time to discontinued use of crutches, discontinued use of narcotic pain medications, and resumed driving was 6 days postoperatively. The mean time to return to work was 8 days, discontinued use of any assistive device was 9 days, and resumption of all activities of daily living was 10 days. The mean time to walk (1/2) mile was 16 days. Furthermore, there were no readmissions, no dislocations, and no reoperations. Therefore, a rapid rehabilitation protocol is safe and fulfills the potential benefits of a rapid recovery with minimally invasive total hip arthroplasty.
Abdel, Matthew P; von Roth, Philipp; Jennings, Matthew T; Hanssen, Arlen D; Pagnano, Mark W
2016-02-01
Numerous factors influence total hip arthroplasty (THA) stability including surgical approach and soft tissue tension, patient compliance, and component position. One long-held tenet regarding component position is that cup inclination and anteversion of 40° ± 10° and 15° ± 10°, respectively, represent a "safe zone" as defined by Lewinnek that minimizes dislocation after primary THA; however, it is clear that components positioned in this zone can and do dislocate. We sought to determine if these classic radiographic targets for cup inclination and anteversion accurately predicted a safe zone limiting dislocation in a contemporary THA practice. From a cohort of 9784 primary THAs performed between 2003 and 2012 at one institution, we retrospectively identified 206 THAs (2%) that subsequently dislocated. Radiographic parameters including inclination, anteversion, center of rotation, and limb length discrepancy were analyzed. Mean followup was 27 months (range, 0-133 months). The majority (58% [120 of 206]) of dislocated THAs had a socket within the Lewinnek safe zone. Mean cup inclination was 44° ± 8° with 84% within the safe zone for inclination. Mean anteversion was 15° ± 9° with 69% within the safe zone for anteversion. Sixty-five percent of dislocated THAs that were performed through a posterior approach had an acetabular component within the combined acetabular safe zones, whereas this was true for only 33% performed through an anterolateral approach. An acetabular component performed through a posterior approach was three times as likely to be within the combined acetabular safe zones (odds ratio [OR], 1.3; 95% confidence interval [CI], 1.1-1.6) than after an anterolateral approach (OR, 0.4; 95% CI, 0.2-0.7; p < 0.0001). In contrast, acetabular components performed through a posterior approach (OR, 1.6; 95% CI, 1.2-1.9) had an increased risk of dislocation compared with those performed through an anterolateral approach (OR, 0.8; 95% CI, 0.7-0.9; p < 0.0001). The historical target values for cup inclination and anteversion may be useful but should not be considered a safe zone given that the majority of these contemporary THAs that dislocated were within those target values. Stability is likely multifactorial; the ideal cup position for some patients may lie outside the Lewinnek safe zone and more advanced analysis is required to identify the right target in that subgroup. Level III, therapeutic study.
Revision of cemented hip arthroplasty using a hydroxyapatite-ceramic-coated femoral component.
Raman, R; Kamath, R P; Parikh, A; Angus, P D
2005-08-01
We report the clinical and radiological outcome of 86 revisions of cemented hip arthroplasties using JRI-Furlong hydroxyapatite-ceramic-coated acetabular and femoral components. The acetabular component was revised in 62 hips and the femoral component in all hips. The mean follow-up was 12.6 years and no patient was lost to follow-up. The mean age of the patients was 71.2 years. The mean Harris hip and Oxford scores were 82 (59 to 96) and 23.4 (14 to 40), respectively. The mean Charnley modification of the Merle d'Aubigné and Postel score was 5 (3 to 6) for pain, 4.9 (3 to 6) for movement and 4.4 (3 to 6) for mobility. Migration of the acetabular component was seen in two hips and the mean acetabular inclination was 42.6 degrees. The mean linear polyethylene wear was 0.05 mm/year. The mean subsidence of the femoral component was 1.9 mm and stress shielding was seen in 23 (28%) with bony ingrowth in 76 (94%). Heterotopic ossification was seen in 12 hips (15%). There were three re-revisions, two for deep sepsis and one for recurrent dislocation and there were no re-revisions for aseptic loosening. The mean EuroQol EQ-5D description scores and health thermometer scores were 0.69 (0.51 to 0.89) and 79 (54 to 95), respectively. With an end-point of definite or probable loosening, the probability of survival at 12 years was 93.9% and 95.6% for the acetabular and femoral components, respectively. Overall survival at 12 years, with removal or further revision of either component for any reason as the end-point, was 92.3%. Our study supports the continued use of this arthroplasty and documents the durability of hydroxyapatite-ceramic-coated components.
Drimal, J
1989-10-01
The authors present in their work the results of the analysis of the relation between congenital dislocation of vertebral joints and social factors which they have found out in 120 children singled out of 9516 live-born children in the Martin district (Slovakia) in the period 1979-1983. The investigation of social factors has been based on the analysis of socioeconomic and social conditions of the Martin district which has no regional particularities. According to their results the share of exogenous factors in the origin and development of this disease is manifested more frequently in the first-borns (having the highest representation in the examined group). On the top of the list of social indices, which they have examined in primiparae and multiparae respectively, there are unsuitable housing conditions (living in discord with mother-in-law in the same house-hold), high percentage of impregnation before marriage which can be considered a strain and longterm conflicting situation and can have together with other factors a sociopathogenetic effect.
Thiagarajah, Shankar; Wilkinson, J. Mark; Panoutsopoulou, Kalliope; Day‐Williams, Aaron G.; Cootes, Timothy F.; Wallis, Gillian A.; Loughlin, John; Arden, Nigel; Birrell, Fraser; Carr, Andrew; Chapman, Kay; Deloukas, Panos; Doherty, Michael; McCaskie, Andrew; Ollier, William E. R.; Rai, Ashok; Ralston, Stuart H.; Spector, Timothy D.; Valdes, Ana M.; Wallis, Gillian A.; Mark Wilkinson, J.; Zeggini, Eleftheria
2015-01-01
Objective To test whether previously reported hip morphology or osteoarthritis (OA) susceptibility loci are associated with proximal femur shape as represented by statistical shape model (SSM) modes and as univariate or multivariate quantitative traits. Methods We used pelvic radiographs and genotype data from 929 subjects with unilateral hip OA who had been recruited previously for the Arthritis Research UK Osteoarthritis Genetics Consortium genome‐wide association study. We built 3 SSMs capturing the shape variation of the OA‐unaffected proximal femur in the entire mixed‐sex cohort and for male/female‐stratified cohorts. We selected 41 candidate single‐nucleotide polymorphisms (SNPs) previously reported as being associated with hip morphology (for replication analysis) or OA (for discovery analysis) and for which genotype data were available. We performed 2 types of analysis for genotype–phenotype associations between these SNPs and the modes of the SSMs: 1) a univariate analysis using individual SSM modes and 2) a multivariate analysis using combinations of SSM modes. Results The univariate analysis identified association between rs4836732 (within the ASTN2 gene) and mode 5 of the female SSM (P = 0.0016) and between rs6976 (within the GLT8D1 gene) and mode 7 of the mixed‐sex SSM (P = 0.0003). The multivariate analysis identified association between rs5009270 (near the IFRD1 gene) and a combination of modes 3, 4, and 9 of the mixed‐sex SSM (P = 0.0004). Evidence of associations remained significant following adjustment for multiple testing. All 3 SNPs had previously been associated with hip OA. Conclusion These de novo findings suggest that rs4836732, rs6976, and rs5009270 may contribute to hip OA susceptibility by altering proximal femur shape. PMID:25939412
Hart, Alister J; Skinner, John A; Henckel, Johann; Sampson, Barry; Gordon, Fabiana
2011-09-01
Many factors affect the blood metal ion levels after metal-on-metal (MOM) hip arthroplasty. The main surgically adjustable variable is the amount of coverage of the head provided by the cup which is a function of the inclination and version angles. However, most studies have used plain radiographs which have questionable precision and accuracy, particularly for version and large diameter metal heads; further, these studies do not simultaneously assess version and inclination. Thus the relationship between version and blood metal ions levels has not been resolved. We determined whether cup inclination and version influence blood metal ion levels while adjusting for age at assessment, gender, body mass index, horizontal femoral offset, head size, manufacturer hip type, and Oxford hip score. We prospectively followed 100 individuals (51 females, 49 males) with unilateral MOM hip resurfacing who underwent clinical assessment, CT scanning, and blood metal ion measurement. Multiple regression analysis was used to determine which variables were predictors of blood metal ion levels and to model the effect of these variables. Only cup inclination, version angles, and gender influenced blood cobalt or chromium levels. Cobalt and chromium levels positively correlated with inclination angle and negatively correlated with version angle. The effect of changes in version angle was less than for inclination angle. Based on our observations, we developed a formula to predict the effect of these parameters on metal ion levels. Our data suggest insufficient cup version can cause high blood metal ions after MOM hip arthroplasty. We were unable to show that excessive version caused high levels. Level II, prognostic study. See Guidelines for Authors for a complete description of levels of evidence.
Hamilton, David F; Ohly, Nicholas E; Gaston, Paul
2018-04-16
The use of shorter length femoral stems during total hip arthroplasty has been suggested to accommodate wider patient femoral geometry and offer maximal bone preservation. However, cemented short-stem designs may increase the risk of varus stem malalignment and influence patient outcomes. CASINO is a multi-centre randomised equivalence trial that will recruit 220 patients undergoing total hip arthroplasty for osteoarthritis at two NHS hospitals in Scotland. Patients will be aged 45-80, undergoing unilateral primary hip arthroplasty, with no plan for contralateral procedure within the study timeframe, and able to comply with the protocol. Participants will be randomised to receive either a short (125 mm) or a standard (150 mm) Exeter V40 stem. The Contemporary acetabular component will be used in all cases. All implants will be cemented. Patient pain, function and satisfaction will be assessed using change from baseline measurement in Oxford Hip Score, Forgotten Joint Score, EQ-5D, pain numerical rating scores, and patient satisfaction questionnaire at baseline and at 1 and 2 years following surgery. Radiographic assessment will evaluate stem position and will be appraised by independent reviewers. Patients will be blind to implant allocation. Stem length may be associated with outcome; however, we can find no randomised trial in which researchers investigated the effect of stem length on patient outcome following cemented total hip arthroplasty. The aim of this trial is to determine if the use of short cemented stems offers equivalent patient outcomes to those achieved following surgery with standard length stems. International Standard Randomised Controlled Trial Number, ISRCTN13154542 , Registered on 30 June 2017.
Formal Physical Therapy After Total Hip Arthroplasty Is Not Required: A Randomized Controlled Trial.
Austin, Matthew S; Urbani, Brian T; Fleischman, Andrew N; Fernando, Navin D; Purtill, James J; Hozack, William J; Parvizi, Javad; Rothman, Richard H
2017-04-19
The value of formal physical therapy after total hip arthroplasty is unknown. With substantial changes that have occurred in surgical and anesthesia techniques, self-directed therapy may be efficacious in restoring function to patients undergoing total hip arthroplasty. We conducted a single-center, randomized trial of 120 patients undergoing primary, unilateral total hip arthroplasty who were eligible for direct home discharge. The experimental group followed a self-directed home exercise program for 10 weeks. The control group received the standard protocol for physical therapy that included in-home visits with a physical therapist for the first 2 weeks followed by formal outpatient physical therapy for 8 weeks. Functional outcomes were measured using validated instruments including the Harris hip score (HHS), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and the Short Form-36 Health Survey (SF-36) preoperatively, at 1 month postoperatively, and at 6 to 12 months postoperatively. Of 120 randomized patients, 108 were included in the final analysis. Ten patients (19%) were randomized to unsupervised home exercise and 20 patients (37%) were randomized to formal outpatient therapy crossed over between groups. There was no significant difference in any of the measured functional outcomes between patients receiving formal therapy (n = 54) and those participating in unsupervised home exercise (n = 54) at any time point (HHS, p = 0.82; WOMAC, p = 0.80; and SF-36 physical health, p = 0.90). This randomized trial suggests that unsupervised home exercise is both safe and efficacious for a majority of patients undergoing total hip arthroplasty, and formal physical therapy may not be required. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.
Mikkelsen, Rasmus T; Fløjstrup, Marianne; Lund, Christian; Kjærsgaard-Andersen, Per; Skjødt, Thomas; Varnum, Claus
2017-09-01
Modular neck femoral stem (MNFS) for total hip arthroplasty (THA) was introduced to optimize the outcome, but created concerns about pain, elevated blood metal ion levels, and adverse reaction to metal debris such as pseudotumors (PTs), related to corrosion between femoral neck and stem. We compared these outcomes in patients with MNFS or nonmodular femoral stem (NFS) THA. Thirty-three patients with unilateral MNFS THA were compared with 30 patients with unilateral NFS THA. Levels of pain, serum cobalt, serum chromium were determined. Magnetic resonance imaging was performed to describe PT and fatty atrophy of muscles. The MNFS and NFS group had a mean follow-up of 2.3 and 3.1 years, respectively. Four and 13 patients in the MNFS and NFS group had pain, respectively (P = .005). The MNFS group had higher levels of serum cobalt (P < .0001) and chromium (P = .006). PTs were present in both the MNFS (n = 15) and NFS (n = 7) groups (P = .066). PTs were related to serum cobalt (P = .04) but not to pain or serum chromium. Fatty atrophy prevalence in the piriformis and gluteal muscles were higher in patients with MNFS (P = .009 and P = .032, respectively). More patients in the NFS group had pain. Serum cobalt and chromium levels were higher in the MNFS group. Prevalence of PTs was twice as high in the MNFS group, but the difference was insignificant. Copyright © 2017 Elsevier Inc. All rights reserved.
Yu, Zhiliang; Zhang, Ning; Yang, Yi; Wang, Bin; Gao, Shuo; Zhao, Xiaoyong
2013-07-01
To investigate the effectiveness of transplanting iliac bone flap with deep iliac circumflex vessels and cancellous bone for the treatment of adult avascular necrosis of the femoral head (ANFH). A retrospective analysis was made on the clinical data of 685 patients (803 hips) with ANFH, who underwent iliac bone flap transplantation with deep iliac circumflex vessels and cancellous bone between March 2002 and January 2010. There were 489 males (580 hips) and 196 females (223 hips) with a mean age of 40.4 years (range, 18-63 years), including 567 unilateral cases (303 left hips and 264 right hips) and 118 bilateral cases. The causes of ANFH included alcohol-induced in 223 cases, steroid-induced in 179 cases, alcohol + steroid-induced in 21 cases, traumatic in 136 cases, acetabular dysplasia in 8 cases, bone cyst in 5 cases, septic arthritis in 2 cases, joint tuberculosis in 3 cases, rheumatoid arthritis in 5 cases, and idiopathic in 103 cases. According to Steinberg staging, 211 hips were rated as stage II, 513 hips as stage III, and 79 hips as stage IV. The preoperative Harris hip score was 60.30 +/- 7.02. Fat necrosis occurred in 2 cases after operation, primary healing of incision was obtained in the other cases; delayed infection, lower extremity deep vein thrombosis, and pulmonary embolism occurred in 2 cases, respectively. All patients were followed up 36-60 months (mean, 49 months). Harris hip score at last follow-up (83.50 +/- 7.31) was significantly higher than that at preoperation (t= -2 266.980, P=0.000), and the scores were significantly higher than those at preoperation in different stages (P < 0.05). The results were excellent in 523 hips, good in 185 hips, fair in 65 hips, and poor in 30 hips, and the excellent and good rate was 88.2%. X-ray examination showed bone fusion of transplanted bone flap and bone graft with an average of 4.2 months (range, 3-6 months); according to Steinberg staging, imaging stable rate was 78.3% (629/803) at last follow-up. Iliac bone flap transplantion with deep iliac circumflex vessels and cancellous bone has the advantages of complete decompression of the femoral head, exact flap blood supply, improved blood supply of the femoral head, new support for the femoral head, and participation of osteoinductive effect for the treatment of adult ANFH, so it is an effective treatment for the retention of the femoral head.
Morphometric analysis of the femur in cerebral palsy: 3-dimensional CT study.
Gose, Shinichi; Sakai, Takashi; Shibata, Toru; Murase, Tsuyoshi; Yoshikawa, Hideki; Sugamoto, Kazuomi
2010-09-01
The cause of hip disorder in cerebral palsy (CP) has been thought to involve muscle imbalance, flexion, and adduction contracture of the hip joint, acetabular dysplasia, and femoral growth abnormalities. The aim of this study was to quantitatively evaluate the 3-dimensional femoral geometry and subluxation/dislocation of the hip in spastic CP using 3D-CT reconstructed images of the pelvis and the femur, focusing on the femoral growth abnormalities in CP. Between June 2006 and September 2009, 186 hips in 93 bilateral spastic CP patients, including spastic diplegia (SD) in 73 patients and spastic quadriplegia (SQ) in 20 patients, who had not received any surgical treatment, were investigated using 3D-CT at our hospital. There were 59 boys and 34 girls with an average age of 5.3 years (range: 2.6 to 6.8 y). As an index for the femoral geometry, the neck-shaft angle, the femoral anteversion, and the femoral offset were 3-dimensionally measured. The center of the acetabulum and the femoral head were determined to calculate the CT migration percentage as the distance between these centers divided by the femoral head diameter. To elucidate the factors related to hip subluxation/dislocation, the relationships between the neck-shaft angle, the femoral anteversion, the femoral offset, and the CT migration percentage were investigated. The mean neck-shaft angle was 150.4+/-9.4 degrees (range: 129.4 to 173.2 degrees). The mean femoral anteversion was 44.4+/-13.6 degrees (range: 5.8 to 84.0 degrees). The mean CT migration percentage was 22.4+/-22.7% (range: 3 to 129%). There was positive correlation between the CT migration percentage and the neck-shaft angle (r=0.49). Hips with large CT migration percentage tended to show coxa valga. There was an inverse correlation between the neck-shaft angle and the femoral offset (r=-0.90), but no correlation between the CT migration percentage and the femoral anteversion (r=0.26), between the femoral offset and the femoral anteversion (r=-0.25), or between the neck-shaft angle and the femoral anteversion (r=0.23). The neck-shaft angle, the femoral anteversion, and the CT migration percentage were significantly larger, and the femoral offset was significantly smaller, in patients with the Gross Motor Functional Classification System (GMFCS) level IV/V (nonwalking children) and SQ type, than in patients with GMFCS level II/III (mostly walking children) and SD type. The 3-dimensional femoral geometry in CP patients can be analyzed quantitatively using 3D-CT regardless of the abnormal spastic posture. Our data indicate that 3-dimensional evaluation is accurate and useful for analysis of the femur and acetabulum in CP, and that the extent of coxa valga and femoral anteversion is more severe in the patients with GMFCS level IV/V and SQ type. Level IV.
Celiktas, Mustafa; Kose, Ozkan; Turan, Adil; Guler, Ferhat; Ors, Cagri; Togrul, Emre
2017-01-01
The purpose of this retrospective study is to report the clinical and radiological outcome of total hip arthroplasty in patients with previous hip arthrodesis. We retrospectively reviewed 28 (40 hips) prospectively followed patients in whom ankylosed hips were converted to total hip arthroplasty (THA) between 2010 and 2014 in our institution. The average age at the time of the conversion operation was 40.8 ± 9.8 years (range 24-62). The ankylosis had lasted 20.4 ± 13.0 years (range 3-56) before conversion surgery. The etiology of the ankylosis was septic arthritis in 10 (25%), post-traumatic hip osteoarthritis in 8 (20%), developmental hip dysplasia in 6 (15%), rheumatoid arthritis in 6 (15%), primary osteoarthritis in 5 (12.5%) and ankylosing spondylitis in 5 (12.5%) hips. The indications for arthroplasty were intractable low back pain in 14 (50%), hip pain in 24 (85.7%), and ipsilateral knee pain in 19 (67.8%) patients. Harris Hip Score (HHS) was used to rate the clinical results before and after the surgery. Radiographic evaluations included component malposition and loosening. All complications during the study period were recorded. The mean follow-up period was 39.9 ± 10.6 months (range 24-60). The mean preoperative HHS was 33.3 ± 8.6 (range 18-50) and the mean HHS at the final follow-up was 74.9 ± 8.6 (range 52-97). There was a statistically significant increase in HHS (p = 0.0001). HHS was excellent in 1, good in 6, fair in 14 and poor in 7 patients. Increase in HHS was lower than 20 points in one patient (18 points), and one patient required two-staged exchange procedure due to deep infection. Thus, according to our success criteria (increase in HHS more than 20 points, radiographically stable implant, and no further surgical reconstruction), 92.8% (26/28) of patients had benefit from the surgery. Trendelenburg sign was positive in 12 hips. There was limb length inequality in 11 patients (mean 0.5 cm, range 1-3 cm). No patients had heterotopic ossification, sciatic nerve palsy or dislocation. There were five intra-operative fractures of the greater trochanter that were treated with cable wiring. One patient had trochanteric avulsion injury and was treated with trochanteric grip and cables. One patient (2.5%) had deep infection one year after the conversion THA and was treated with two-staged exchange procedure. Conversion hip arthroplasty is an effective treatment method which provides functional recovery and patient satisfaction. However, a proper surgical technique and planning is necessary to minimize the complications.
Kang, Alan C L; Gooding, Andrew J; Coates, Mark H; Goh, Tony D; Armour, Paul; Rietveld, John
2010-06-01
Femoroacetabular impingement has become a well-recognized entity predisposing to acetabular labral tears and chondral damage, and subsequently development of osteoarthritis of the hip joint. In the authors' experience, it is common to see bony abnormalities predisposing to femoroacetabular impingement in the contralateral asymptomatic hips in patients with unilateral femoroacetabular impingement. This study was undertaken to investigate the prevalence of bony abnormalities predisposing to femoroacetabular impingement in asymptomatic individuals without exposing study participants to unnecessary radiation. Cross-sectional study; Level of evidence, 4. Fifty individuals (100 hip joints), ranging from 15 to 40 years of age, who were seen at a local hospital between March and August 2008 with abdominal trauma or nonspecific abdominal pain in whom abdominal computed tomography was performed to aid diagnosis were prospectively studied. These patients were not known to have any history of hip-related problems. Raw data from the abdominal computed tomography scan, performed on a 64-slice multidetector computed tomography scanner, were reformatted using bone algorithm into several different planes. Several measurements and observations of the hip joints were made in relation to femoroacetabular impingement. The 100 hip joints from 50 patients with no history of hip problems demonstrated that 39% of the joints (31% of female, 48% of male joints) have at least 1 morphologic aspect predisposing to femoroacetabular impingement. The majority (66% to 100% ) of the findings were bilateral; 33% of female and 52% of male asymptomatic participants in our study had at least 1 predisposing factor for femoroacetabular impingement in 1 or both of their hip joints. Based on the data collected from this study, the acetabular crossover sign had a 71% sensitivity and 88% specificity for detecting acetabular retroversion. Nonquantitative assessment of the femoral head at the anterior, anterolateral, and lateral head/neck junctions demonstrated that 74% of the joints had an aspherical femoral head. The study demonstrated substantial prevalence of bony characteristics predisposing to femoroacetabular impingement in asymptomatic individuals according to the established measurement parameters in current literature.
Complications of porous-coated press-fit cementless total hip replacement in dogs.
Kidd, Scott W; Preston, Christopher A; Moore, George E
2016-09-20
To report postoperative complications using a commercially available porous-coated press-fit cementless total hip replacement (THR) system in dogs. Medical records were reviewed for client-owned dogs with hip pathologies requiring THR. A minimum of six-week postoperative orthopaedic examination and orthogonal pelvic radiographs were used to assess outcome and complications in the perioperative period. Referring veterinarian medical records, phone interviews with clients, or both were used to assess long-term functional outcome and complications. Bilateral THR was performed in 36 dogs, and unilateral in 147 dogs, making a total of 219 THR procedures in 183 dogs. A total complication rate of 31.1% (68/219) was observed. A catastrophic complication was observed in 8.2% (n = 18), a major complication in 9.6% (n = 21), and a minor complication in 13.2% (n = 29) of procedures. The most common complications were intra-operative femoral fissure (n = 46), diaphyseal femoral fracture (n = 15), and coxofemoral luxation (n = 9). Full return to function was achieved in 88.1% of procedures with a median follow-up period of 42 months. Porous-coated press-fit cementless collarless total hip replacements have a high complication rate. The majority of complications occur intra-operatively or perioperatively, with few complications occurring beyond 12 weeks postoperatively. Both fissure fractures and diaphyseal femoral fractures carry a favourable prognosis with immediate cerclage wiring and plate fixation, respectively.
Hopley, Colin; Stengel, Dirk; Ekkernkamp, Axel; Wich, Michael
2010-06-11
To determine whether total hip arthroplasty is associated with lower reoperation rates, mortality, and complications, and better function and quality of life than hemiarthroplasty for displaced fractures of the femoral neck in older patients. Systematic review and meta-analysis of randomised trials, quasirandomised trials, and cohort studies. Medline, Embase, Cochrane register of controlled trials, publishers' databases, and manual search of bibliographies. Randomised controlled trials, quasirandomised trials, and cohort studies (retrospective and prospective) comparing hemiarthroplasty with total hip arthroplasty for treating displaced femoral neck fractures in patients aged more than 60 years. Relative risks, risk differences, and mean differences from each trial, aggregated using random effects models. Analyses were stratified for experimental and non-experimental designs, and two way sensitivity analyses and tests for interaction were done to assess the influence of various criteria of methodological quality on pooled estimates. 3821 references were identified. Of the 202 full papers inspected, 15 were included (four randomised controlled trials, three quasirandomised trials, and eight retrospective cohort studies, totalling 1890 patients). Meta-analysis of 14 studies showed a lower risk of reoperation after total hip arthroplasty compared with hemiarthroplasty (relative risk 0.57, 95% confidence interval 0.34 to 0.96, risk difference 4.4%, 95% confidence interval 0.2% to 8.5%), although this effect was mainly driven by investigations without concealed treatment allocation. Total hip arthroplasty consistently showed better ratings in the Harris hip score (three studies, 246 patients, weighted mean difference 5.4, 95% confidence interval 2.7 to 8.2) after follow-up periods of 12 to 48 months. The standardised mean difference of different scores from five studies was 0.42 (95% confidence interval 0.24 to 0.61), indicating a medium functional advantage of total hip arthroplasty over hemiarthroplasty. Total hip arthroplasty was associated with a slightly higher risk of dislocation (relative risk 1.48, 95% confidence interval 0.89 to 2.46) and general complications (1.14, 0.87 to 1.48). Single stage total hip arthroplasty may lead to lower reoperation rates and better functional outcomes compared with hemiarthroplasty in older patients with displaced femoral neck fractures. However, heterogeneity across the available trials and distinct subgroup effects preclude definitive statements and require further research in this area.
Liu, Ruiyu; Li, Yongwei; Fan, Lihong; Mu, Mingchao; Wang, Kunzheng; Song, Wei
2015-12-01
Limb length discrepancy (LLD) is common in patients with developmental dysplasia of the hip (DDH) and may influence the psychological status of these patients. The present study aims to investigate depression and anxiety in DDH patients with different extents of LLD and to assess the effect of LLD correction on these two psychological factors. 161 patients with DDH were recruited and divided into two groups based on whether they could perceive LLD preoperatively. The patients who could not perceive LLD were assigned to group N, and those who could perceive LLD were assigned to group P. Depression/anxiety, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores and LLD were assessed one week before, six months and two years after total hip arthroplasty (THA). Depression and anxiety were significantly higher in group P patients compared to group N patients. The patients in group N presented significant improvement in depression and anxiety six months after arthroplasty, while DDH patients in group P did two years after arthroplasty. Correlation analyses revealed their improvement was associated with pain relief and improved hip function in both groups of patients and was also related to changes in the perception of LLD in group P patients. Depression and anxiety levels were higher in DDH patients with perceived LLD. Their improvement was related to pain relief and improved hip function following THA. In DDH patients with perceived LLD, a change in the perception of LLD also played a part in their improvement. Copyright © 2015 Elsevier Inc. All rights reserved.
Matched cohort study of topical tranexamic acid in cementless primary total hip replacement.
Sanz-Reig, Javier; Mas Martinez, Jesus; Verdu Román, Carmen; Morales Santias, Manuel; Martínez Gimenez, Enrique; Bustamante Suarez de Puga, David
2018-03-29
Tranexamic acid has been shown to be effective in reducing blood loss after total hip replacement. The purpose of this study was to prospectively assess the effectiveness of topical TXA use to reduce blood loss after primary total hip replacement and to compare these outcomes with those of a matched control group from a similar cohort that did not have received tranexamic acid. This is a prospective matched control study to assess the effect of a 2 g topical tranexamic acid in 50 mL physiological saline solution in total hip replacement. Primary outcomes were hemoglobin and hematocrit drop, and total blood loss. Secondary outcomes were transfusion rates, length of hospital stay, deep vein thrombosis, and pulmonary embolism events. We could match 100 patients to a control group. There were no statistical significantly differences between the two groups. The hemoglobin and hematocrit postoperative values were significantly higher in topical tranexamic acid group than in control group (P < 0.001). The mean total blood loss was 769 in topical tranexamic acid group and 1163 in control group with significant differences (P = 0.001), which meant 34% reduction in total blood loss. Length of stay was lower in topical tranexamic acid group. The risk of deep vein thrombosis and pulmonary events did not increase. A single dose of 2 g tranexamic acid in 50 mL physiological saline solution topical administration was effective and safe in reducing bleeding in patients undergoing unilateral primary non-cemented total hip replacement compared to a matched control group.
The Frank Stinchfield Award. Pulmonary fat embolism in revision hip arthroplasty.
Woo, R; Minster, G J; Fitzgerald, R H; Mason, L D; Lucas, D R; Smith, F E
1995-10-01
Unilateral cemented hip hemiarthroplasty was done on 16 dogs who subsequently had revision arthroplasty and who were divided into 1 control and 3 experimental groups: The first group had cement extraction using osteotomes; the second, using a high speed burr; the third, an ultrasonic tool. Hemodynamic and transesophageal echocardiographic monitoring were done. Postmortem pulmonary specimens were examined for differences in the quantity of fat emboli. There was a significant increase in emboli with the ultrasonic tool as compared with osteotomes and high speed burr. There was no significant difference in emboli between the osteotomes and high speed burr. Fat emboli syndrome is related to mechanical compression of the femoral canal. The ultrasonic instrument was unique in its tendency to cause large embolic showers, especially during extraction of the distal cement plug. In these young dogs, minimal hemodynamic changes and no cardiac dysrhythmias occurred, which in part may be attributed to their good health. These changes may remain subclinical for patients with good cardiorespiratory reserve, or may become life threatening for those with poor reserve. By outlining the mechanisms of fat embolism in revision total hip arthroplasty, it may be possible to decrease future morbidity, especially in patients who frequently have cardiopulmonary disease.
Amodio, John; Rivera, Rafael; Pinkney, Lynne; Strubel, Naomi; Fefferman, Nancy
2006-08-01
The arterial vascularity of the hip has been investigated in normal infants using duplex Doppler sonography. This study addressed the differences in hip vascularity in infants with respect to gender and acetabular morphology. To determine whether there is a relationship between the resistive index of the vessels of the femoral chondroepiphysis and the alpha angle in normal infant hips and in those with developmental dysplasia of the hip. We studied 76 hips (38 patients) with gray-scale and power Doppler US. The patients were referred because of a possible abnormal clinical hip examination or had risk factors for developmental dysplasia of the hip. The infants ranged in age from 1 day to 6 weeks. There were 13 boys and 25 girls. Gray-scale images were initially performed in the coronal and transverse planes to evaluate acetabular morphology, alpha angle and position of the femoral chondroepiphysis relative to the acetabulum. The hips were then examined with power Doppler US, in both sagittal and transverse planes, to identify arterial vessels within the femoral epiphysis. Resistive indices were then recorded from the spectral analysis in each vessel identified. Each examination was performed by one of five pediatric radiologists. Mixed model regression was used to assess the relationship between resistive index and alpha angle, age and gender. Of the 76 hips, 34 had an alpha angle of 60 degrees or greater and were classified as normal, 26 had an alpha angle between 50 degrees and 59 degrees and were classified as immature, and 13 had an alpha angle of less than 50 degrees and were either subluxed or dislocated at the time of examination. At least two vessels were documented in each femoral epiphysis except in three hips, in which no vessels could be documented because of technical factors. There was a statistically significant linear relationship between the alpha angle and resistive index, such that the resistive index tended to rise with increasing alpha angle (P=0.0022). In addition, female infants had a significantly higher average resistive index than the average resistive index in male infants with the same alpha angle (P=0.0005). There is a direct linear relationship between alpha angle and resistive index in the infant hip. Female infants have a higher average resistive index than male infants. We believe that these results might serve as a model for predicting an infant hip at risk of ischemia. In addition, the fact that lower resistive indices of the femoral epiphysis are associated with acetabular dysplasia might help explain the documented low incidence of avascular necrosis in untreated hip dysplasia.
A Review of Periprosthetic Femoral Fractures Associated With Total Hip Arthroplasty
Marsland, Daniel; Mears, Simon C.
2012-01-01
Periprosthetic fractures of the femur in association with total hip arthroplasty are increasingly common and often difficult to treat. Patients with periprosthetic fractures are typically elderly and frail and have osteoporosis. No clear consensus exists regarding the optimal management strategy because there is limited high-quality research. The Vancouver classification facilitates treatment decisions. In the presence of a stable prosthesis (type-B1 and -C fractures), most authors recommend surgical stabilization of the fracture with plates, strut grafts, or a combination thereof. In up to 20% of apparent Vancouver type-B1 fractures, the femoral stem is loose, which may explain the high failure rates associated with open reduction and internal fixation. Some authors recommend routine opening and dislocation of the hip to perform an intraoperative stem stability test to rule out a loose component. Advances in plating techniques and technology are improving the outcomes for these fractures. For fractures around a loose femoral prosthesis (types B2 and 3), revision using an extensively porous-coated uncemented long stem, with or without additional fracture fixation, appears to offer the most reliable outcome. Cement-in-cement revision using a long-stem prosthesis is feasible in elderly patients with a well-fixed cement mantle. It is essential to treat the osteoporosis to help fracture healing and to prevent further fractures. We provide an overview of the causes, classification, and management of periprosthetic femoral fractures around a total hip arthroplasty based on the current best available evidence. PMID:23569704
Buttaro, Martín A; Slullitel, Pablo A; García Mansilla, Agustín M; Carlucci, Sofía; Comba, Fernando M; Zanotti, Gerardo; Piccaluga, Francisco
2017-03-01
Incapacitating articular sequelae in the hip joint have been described for patients with late effects of poliomyelitis. In these patients, total hip arthroplasty (THA) has been associated with a substantial rate of dislocation. This study was conducted to evaluate the long-term clinical and radiologic outcomes of unconstrained THA in this specific group of patients. The study included 6 patients with ipsilateral polio who underwent primary THA between 1985 and 2006. Patients with polio who underwent THA on the nonparalytic limb were excluded. Mean follow-up was 119.5 months (minimum, 84 months). Clinical outcomes were evaluated with the modified Harris Hip Score (mHHS) and the visual analog scale (VAS) pain score. Radiographs were examined to identify the cause of complications and determine the need for revision surgery. All patients showed significantly better functional results when preoperative and postoperative mHHS (67.58 vs 87.33, respectively; P=.002) and VAS pain score (7.66 vs 2, respectively; P=.0003) were compared. Although 2 cases of instability were diagnosed, only 1 patient needed acetabular revision as a result of component malpositioning. None of the patients had component loosening, osteolysis, or infection. Unconstrained THA in the affected limb of patients with poliomyelitis showed favorable long-term clinical results, with improved function and pain relief. Nevertheless, instability may be a more frequent complication in this group of patients compared with the general population. [Orthopedics. 2017; 40(2):e255-e261.]. Copyright 2016, SLACK Incorporated.
Early Outcomes of Primary Total Hip Arthroplasty After Prior Lumbar Spinal Fusion.
Barry, Jeffrey J; Sing, David C; Vail, Thomas P; Hansen, Erik N
2017-02-01
The coexistence of degenerative hip disease and spinal pathology is not uncommon with the number of surgical treatments performed for each condition increasing annually. The limited research available suggests spinal pathology portends less pain relief and worse outcomes after total hip arthroplasty (THA). We hypothesize that primary THA patients with preexisting lumbar spinal fusions (LSF) experience worse early postoperative outcomes. This study is a retrospective matched cohort study. Primary THA patients at 1 institution who had undergone prior LSF (spine arthrodesis-hip arthroplasty [SAHA]) were identified and matched to controls of primary THA without LSF. Early outcomes (<90 days) were compared. From 2012 to 2014, 35 SAHA patients were compared to 70 matched controls. Patients were similar in age, sex, American Society of Anesthesiologist score, body mass index, and Charlson Comorbidity Index. SAHA patients had higher rates of complications (31.4% vs 8.6%, P = .008), reoperation (14.3% vs 2.9%, P = .040), and general anesthesia (54.3% vs 5.7%, P = .0001). Bivariate analysis demonstrated SAHA to predict reoperation (odds ratio, 5.67; P = .045) and complications (odds ratio, 4.89; P = .005). With the numbers available, dislocations (0% vs 2.8%), infections (0% vs 8.6%), readmissions, postoperative walking distance, and disposition only trended to favor controls (P > .05). Comparing controls to SAHA patients with <3 or ≥3 levels fused, longer fusions had increased cumulative postoperative narcotic consumption (mean morphine equivalents, 44.3 vs 46.9 vs 169.4; P = .001). Patients with preexisting LSF experience worse early outcomes after primary THA including higher rates of complications and reoperation. Lower rates of neuraxial anesthesia and increased narcotic usage represent potential contributors. The complex interplay between the lumbar spine and hip warrants attention and further investigation. Copyright © 2016 Elsevier Inc. All rights reserved.
Zwawi, Mohammed A; Moslehy, Faissal A; Rose, Christopher; Huayamave, Victor; Kassab, Alain J; Divo, Eduardo; Jones, Brendan J; Price, Charles T
2017-08-01
This study utilized a computational biomechanical model and applied the least energy path principle to investigate two pathways for closed reduction of high grade infantile hip dislocation. The principle of least energy when applied to moving the femoral head from an initial to a final position considers all possible paths that connect them and identifies the path of least resistance. Clinical reports of severe hip dysplasia have concluded that reduction of the femoral head into the acetabulum may occur by a direct pathway over the posterior rim of the acetabulum when using the Pavlik harness, or by an indirect pathway with reduction through the acetabular notch when using the modified Hoffman-Daimler method. This computational study also compared the energy requirements for both pathways. The anatomical and muscular aspects of the model were derived using a combination of MRI and OpenSim data. Results of this study indicate that the path of least energy closely approximates the indirect pathway of the modified Hoffman-Daimler method. The direct pathway over the posterior rim of the acetabulum required more energy for reduction. This biomechanical analysis confirms the clinical observations of the two pathways for closed reduction of severe hip dysplasia. The path of least energy closely approximated the modified Hoffman-Daimler method. Further study of the modified Hoffman-Daimler method for reduction of severe hip dysplasia may be warranted based on this computational biomechanical analysis. © 2016 The Authors. Journal of Orthopaedic Research Published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society. J Orthop Res 35:1799-1805, 2017. © 2016 The Authors. Journal of Orthopaedic Research Published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society.
Chammout, Ghazi; Muren, Olle; Laurencikas, Evaldas; Bodén, Henrik; Kelly-Pettersson, Paula; Sjöö, Helene; Stark, André; Sköldenberg, Olof
2017-01-01
Background and purpose Total hip replacement (THR) is the preferred method for the active and lucid elderly patient with a displaced femoral neck fracture (FNF). Controversy still exists regarding the use of cemented or uncemented stems in these patients. We compared the effectiveness and safety between a modern cemented, and a modern uncemented hydroxyapatite-coated femoral stem in patients 65–79 years of age who were treated with THR for displaced FNF. Patients and methods In a single-center, single-blinded randomized controlled trial, we included 69 patients, mean age 75 (65–79) and with a displaced FNF (Garden III–IV). 35 patients were randomized to a cemented THR and 34 to a reverse-hybrid THR with an uncemented stem. Primary endpoints were: prevalence of all hip-related complications and health-related quality of life, evaluated with EuroQol-5D (EQ-5D) index up to 2 years after surgery. Secondary outcomes included: overall mortality, general medical complications, and hip function. The patients were followed up at 3, 12, and 24 months. Results According to the calculation of sample size, 140 patients would be required for the primary endpoints, but the study was stopped when only half of the sample size was included (n = 69). An interim analysis at that time showed that the total number of early hip-related complications was substantially higher in the uncemented group, 9 (among them, 3 dislocations and 4 periprosthetic fractures) as compared to 1 in the cemented group. The mortality and functional outcome scores were similar in the 2 groups. Interpretation We do not recommend uncemented femoral stems for the treatment of elderly patients with displaced FNFs. PMID:27967333
Assessment of Accuracy and Reliability in Acetabular Cup Placement Using an iPhone/iPad System.
Kurosaka, Kenji; Fukunishi, Shigeo; Fukui, Tomokazu; Nishio, Shoji; Fujihara, Yuki; Okahisa, Shohei; Takeda, Yu; Daimon, Takashi; Yoshiya, Shinichi
2016-07-01
Implant positioning is one of the critical factors that influences postoperative outcome of total hip arthroplasty (THA). Malpositioning of the implant may lead to an increased risk of postoperative complications such as prosthetic impingement, dislocation, restricted range of motion, polyethylene wear, and loosening. In 2012, the intraoperative use of smartphone technology in THA for improved accuracy of acetabular cup placement was reported. The purpose of this study was to examine the accuracy of an iPhone/iPad-guided technique in positioning the acetabular cup in THA compared with the reference values obtained from the image-free navigation system in a cadaveric experiment. Five hips of 5 embalmed whole-body cadavers were used in the study. Seven orthopedic surgeons (4 residents and 3 senior hip surgeons) participated in the study. All of the surgeons examined each of the 5 hips 3 times. The target angle was 38°/19° for operative inclination/anteversion angles, which corresponded to radiographic inclination/anteversion angles of 40°/15°. The simultaneous assessment using the navigation system showed mean±SD radiographic alignment angles of 39.4°±2.6° and 16.4°±2.6° for inclination and anteversion, respectively. Assessment of cup positioning based on Lewinnek's safe zone criteria showed all of the procedures (n=105) achieved acceptable alignment within the safe zone. A comparison of the performances by resident and senior hip surgeons showed no significant difference between the groups (P=.74 for inclination and P=.81 for anteversion). The iPhone/iPad technique examined in this study could achieve acceptable performance in determining cup alignment in THA regardless of the surgeon's expertise. [Orthopedics. 2016; 39(4):e621-e626.]. Copyright 2016, SLACK Incorporated.
Hausselle, Jerome; Moreau, Pierre Etienne; Wessely, Loic; de Thomasson, Emmanuel; Assi, Ayman; Parratte, Sebastien; Essig, Jerome; Skalli, Wafa
2012-08-01
Acetabular component malalignment in total hip arthroplasty can lead to potential complications such as dislocation, component impingement and excessive wear. Computer-assisted orthopaedic surgery systems generally use the anterior pelvic plane (APP). Our aim was to investigate the reliability of anatomical landmarks accessible during surgery and to define new potential planes of reference. Three types of palpations were performed: virtual, on dry bones and on two cadaveric specimens. Four landmarks were selected, the reproducibility of their positioning ranging from 0.9 to 2.3 mm. We then defined five planes and tested them during palpations on two cadaveric specimens. Two planes produced a mean orientation error of 5.0° [standard deviation (SD 3.3°)] and 5.6° (SD 2.7°). Even if further studies are needed to test the reliability of such planes on a larger scale in vivo during surgery, these results demonstrated the feasibility of defining a new plane of reference as an alternative to the APP.
Sun, Hong; Fang, Shuying; Yang, Zibo; Zhang, Zhiqi; Kang, Yan; Zhang, Ziji; Liao, Weiming; Fu, Ming; Wu, Peihui
2016-11-08
To investigate the influence of the degree of acetabular deformity and the learning-curve on the acetabular cup positions in total hip arthroplasty (THA) for adults with developmental dysplasia of hip (DDH). Between January 2008 and December 2015, 130 patients (144 hips) with DDH underwent primary THA, and the clinical data were analyzed retrospectively. Fifty-three patients (59 hips) were admitted before 2012, and 77 patients (85 hips) were treated after 2012. There were 32 males and 98 females, aged from 31 to 83 years (mean, 61). Unilateral replacement was performed in 116 cases and bilateral replacement in 14 cases. Of 144 hips, 48 hips were rated as Crowe type I, 57 hips as type II, and 39 hips as type of III/IV. The standard pelvic radiograph was taken within 1 week after operation. The mediCAD software was adopted to measure the angle of anteversion and abduction, bony coverage, and the distance between true rotating center and optimal rotating center to the connection of teardrops and the horizontal distance between two centers to evaluate the qualified rate of acetabular cup positions. Compared with the patients with the same type in 2013-2015 group, the anteversion angle and qualified rate of acetabular cup position significantly decreased in patients with Crowe I ( P <0.05); the horizontal distance significantly increased and qualified rate of acetabular cup position significantly decreased in patients with Crowe II ( P <0.05); and the anteversion angle significantly decreased and the horizontal distance significantly increased in patients with Crowe III/IV ( P <0.05) in 2008-2012 group. But no significant difference was shown in the other indexes ( P >0.05). In all Crowe types, the vertical distance between the true rotating center and the optimal rotating center increased with the degree of acetabular deformity in both 2008-2012 group and 2013-2015 group, showing significant difference ( P <0.05), but no significant difference was found in the other indexes ( P >0.05). For adults with acetabular dysplasia, there are high potential risks for unsatisfactory acetabular cup positions during primary THA. So it is necessary to evaluate acetabular deformities and to sum up operative experience so as to improve the accuracy of cups installation.
Carrying asymmetric loads during stair negotiation.
Wang, Junsig; Gillette, Jason
2017-03-01
Individuals often carry items in one hand instead of both hands during activities of daily living. The combined effects of carrying asymmetric loads and stair negotiation may create even higher demands on the low back and lower extremity. The purpose of this study was to investigate the effect of symmetric and asymmetric loading conditions on L5/S1 and lower extremity moments during stair negotiation. Twenty-two college students performed stair ascent and stair descent on a three-step staircase (step height 18.5cm, tread depth 29.5cm) at preferred pace under five load conditions: no load, 10% body weight (BW) unilateral load, 20% BW unilateral load, 10% BW bilateral load, and 20% BW bilateral load. Video cameras and force platforms were used to collect kinematic and kinetic data. Inverse dynamics was used to calculate frontal plane moments for the L5/S1 and lower extremity. A 20% BW unilateral load resulted in significantly higher peak L5/S1 lateral bending, hip abduction, and external knee varus moments than nearly all other loading conditions during stair ascent and stair descent. Therefore, we suggest potential benefits when carrying symmetrical loads as compared to an asymmetric load in order to decrease the frontal joint moments, particularly at 20% BW load. Copyright © 2017 Elsevier B.V. All rights reserved.
Mahan, Susan T.; Katz, Jeffrey N.; Kim, Young-Jo
2009-01-01
Background: The United States Preventive Services Task Force recently determined that they could not recommend any screening strategies for developmental dysplasia of the hip. Disparate findings in the literature and treatment-related problems have led to confusion about whether or not to screen for this disorder. The purpose of the present study was to determine, with use of expected-value decision analysis, which of the following three strategies leads to the best chance of having a non-arthritic hip by the age of sixty years: (1) no screening for developmental dysplasia of the hip, (2) universal screening of newborns with both physical examination and ultrasonography, or (3) universal screening with physical examination but only selective use of ultrasonography for neonates considered to be at high risk. Methods: Developmental dysplasia of the hip, avascular necrosis, and the treatment algorithm were carefully defined. The outcome was determined as the probability of any neonate having a non-arthritic hip through the age of sixty years. A decision tree was then built with decision nodes as described above, and chance node probabilities were determined from a thorough review of the literature. Foldback analysis and sensitivity analyses were performed. Results: The expected value of a favorable hip outcome was 0.9590 for the strategy of screening all neonates with physical examination and selective use of ultrasonography, 0.9586 for screening all neonates with physical examination and ultrasonography, and 0.9578 for no screening. A lower expected value implies a greater risk for the development of osteoarthritis as a result of developmental dysplasia of the hip or avascular necrosis; thus, the optimum strategy was selective screening. This model was robust to sensitivity analysis, except when the rate of missed dysplasia rose as high as 4/1000 or the rate of treated hip subluxation/dislocation was the same; then, the optimum strategy was to screen all neonates with both physical examination and ultrasonography. Conclusions: Our decision analytic model indicated that the optimum strategy, associated with the highest probability of having a non-arthritic hip at the age of sixty years, was to screen all neonates for hip dysplasia with a physical examination and to use ultrasonography selectively for infants who are at high risk. Additional data on the costs and cost-effectiveness of these screening policies are needed to guide policy recommendations. Level of Evidence: Economic and decision analysis Level II. See Instructions to Authors for a complete description of levels of evidence. PMID:19571094
Nicholson, Allen D; Huez, Coridon M; Sanders, James O; Liu, Raymond W; Cooperman, Daniel R
2016-03-01
In 2 recent studies, modified Oxford hip scores of 16 through 18 have been shown to predict an extremely high risk of contralateral slipping in unilateral slipped capital femoral epiphysis (SCFE). However, the modified Oxford system is not widely used. This may be due, in part, to the complexity of the scoring system, difficulty in viewing all 5 radiographic features on a single x-ray and phenotypic variation in the features. Ossification of the calcaneal apophysis provides an osteologic marker of skeletal maturation in relation to peak height velocity and has been described previously. We examine the value of the calcaneal apophyseal ossification sequence for predicting modified Oxford hip scores. We examined 279 pelvis and matching foot x-rays that were taken at the same session from 94 healthy children aged 3 to 18 years. A fellowship-trained pediatric orthopaedist determined the modified Oxford hip score for each hip radiograph. The calcaneal x-rays had been previously graded. Modified Oxford hip scores were compared with calcaneal scores for each set of matched hip and calcaneal x-rays. Stage 0 to 2 calcanei had 94% of corresponding hip radiographs rated as modified Oxford scores of 16 to 18. Stage 3 calcanei had 54% rated as 16 to 18 and 31% rated as scores 19 to 21. Stage 4 calcanei had 31% rated as scores 19 to 21, and 68% rated as scores 22 to 26. Stage 5 calcanei had 100% rated as 22 to 26. Using data from Popejoy and colleagues' study, the weighted risk of contralateral SCFE was 94% for calcaneal stage 0, 86.5% for calcaneal stage 1, 90.3% for calcaneal stage 2, 55.8% for calcaneal stage 3, 6.1% for calcaneal stage 4, and 0 for calcaneal stage 5. Calcaneal stages 0 to 3 correspond entirely to modified Oxford scores indicating elevated risk of contralateral SCFE. The calcaneal scoring system has potential for adjunctive use with the modified Oxford score for prediction of contralateral SCFE.
Ueno, Masaya; Sonohata, Motoki; Fukumori, Norio; Kawano, Shunsuke; Kitajima, Masaru; Mawatari, Masaaki
2016-01-01
Tranexamic acid has been reported to be safer with topical administration than with intravenous administration in total knee arthroplasty. However, the most effective administration route of tranexamic acid in total hip arthroplasty remains controversial. This study compared the effectiveness of topical tranexamic acid administration with that of intravenous tranexamic acid administration in total hip arthroplasty. We retrospectively examined the medical records of 886 patients with osteoarthritis of the hip joint, who had undergone unilateral primary total hip arthroplasty. The patients were divided into a control group (n = 302; did not receive tranexamic acid), topical group (n = 265; topically administered 2 g tranexamic acid in 30 mL normal saline via drain tubes placed in the joint before wound closure along with posterior soft tissue repair), and intravenous group (n = 319; intravenously administered 1 g tranexamic acid before skin incision along with posterior soft tissue repair). Data on blood loss, hemoglobin levels, transfusion rates, and occurrence of deep vein thrombosis and pulmonary embolization were collected. The mean operation times were approximately 40 min in all of the groups. The operation time and intra-operative blood loss were significantly lower in the control group than in the topical and intravenous groups. However, the post-operative blood loss, total blood loss, and decrease in the hemoglobin level were significantly higher in the control group than in the topical and intravenous groups. There were no significant differences in terms of blood loss and systemic complications between the tranexamic acid administration methods. Tranexamic acid reduces both post-operative and total blood loss in total hip arthroplasty. Moreover, a lower amount of tranexamic acid can be used to reduce blood loss in total hip arthroplasty with intravenous tranexamic acid administration than with topical tranexamic acid administration. Therefore, we suggest that tranexamic acid should be intravenously administered pre-operatively and the posterior soft tissue should be repaired to decrease total hip arthroplasty-related complications. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.
Vincent, John; Alshaygy, Ibrahim; Muir, Jeffrey M; Kuzyk, Paul
2018-01-01
While intraoperative navigation systems have been shown to improve outcomes in primary total hip arthroplasty (THA), their use in the context of revision has been largely overlooked. This case report presents the first documented use of an imageless navigation tool in the context of revision THA, and an unexpected benefit to the surgical procedure as a result. An 84-year-old female patient presented following five episodes of dislocation of the left hip and with pain in the left buttock, groin, and posterior aspect of her hip. Relevant surgical history included primary hip arthroplasty in 1999 and the first revision in 2014. Preoperative analysis revealed a constrained liner that had become disengaged and migrated inferiorly, lodging at the distal aspect of the femoral neck. Acetabular protrusion was also noted. The pre-operative plan included the replacement of the fragmented liner and likely of the acetabular cup due to hardware failure. Intraoperative assessment, however, revealed that the cup was in good condition and would be difficult to remove due to substantial bony ingrowth. With the assistance of imageless navigation, the orientation of the acetabular cup was determined and a new constrained liner was cemented into the preexisting acetabular component at an altered orientation, correcting anteversion by 7°. In revision hip arthroplasty cases, image-based navigation is limited by the presence of existing implants and corresponding metal artefact. This case demonstrates the successful use of an imageless navigation tool for revision surgery. Use of navigation led to the unexpected intraoperative discovery that the acetabular cup was in an acceptable state, and allowed the surgical team to correct the position of the cup using a constrained liner, thus preserving the cup. This significantly benefitted patient outcome, due to the risks associated with the removal of a firmly fixated acetabular cup. While more extensive research is required, this case demonstrates that imageless navigation may be an indispensable tool for revision surgery.
Ancelin, D; Reina, N; Cavaignac, E; Delclaux, S; Chiron, P
2016-12-01
Total hip arthroplasty is the most widely used procedure to treat avascular necrosis (AVN) of the femoral head. Few studies have compared the outcomes of THA in femoral head AVN and primary hip osteoarthritis. Therefore we performed a case-control study to compare THA for femoral head AVN vs. primary hip osteoarthritis in terms of: (1) prosthesis survival, (2) complication rates, (3) functional outcomes and radiographic outcomes, (4) and to determine whether specific risk factors for THA failure exist in femoral head AVN. THA survival is similar in femoral head AVN and primary hip osteoarthritis. We compared two prospective cohorts of patients who underwent THA before 65 years of age, one composed of cases with femoral head AVN and the other of controls with primary hip osteoarthritis. In both cohorts, a cementless metal-on-metal prosthesis with a 28-mm cup and an anatomical stem was used. Exclusion criteria were THA with other types of prosthesis, posttraumatic AVN, and secondary osteoarthritis. With α set at 5%, to obtain 80% power, 246 patients were required in all. Prosthesis survival was assessed based on time to major revision (defined as replacement of at least one implant fixed to bone) and time to aseptic loosening. The other evaluation criteria were complications, Postel-Merle d'Aubigné (PMA) score, and the Engh and Agora Radiographic Assessment (ARA) scores for implant osseointegration. The study included 282 patients, 149 with AVN and 133 with osteoarthritis. Mean age was 47.8±10.2 years (range, 18.5-65) and mean follow-up was 11.4±2.8 years (range, 4.5-18.3 years). The 10-year survival rates were similar in the two groups: for major revision, AVN group, 92.5% (95% confidence interval [95% CI], 90.2-94.8) and osteoarthritis group, 95.3% (95% CI, 92.9-97.7); for aseptic loosening, AVN group, 98.6% (95% CI, 97.6-98.6) and osteoarthritis, 99.2% (95% CI, 98.4-100). The AVN group had higher numbers of revision for any reason (19 vs. 6, P=0.018) and for dislocation (8 vs. 1, P=0.031). Mean PMA scores at last follow-up were comparable in the AVN group (17.65±1.27 [range, 10-18]) and osteoarthritis group (17.59±1.32 [range, 14-18]) (P=0.139). Osseointegration was also similar in the two groups: global Engh score, 26.51±1.81 (range, 14-27) for AVN and 26.84±0.91 (range, 19.5-27) for osteoarthritis (P=0.065); femoral ARA score, 5.83±0.46 (range, 3-6) for AVN and 5.90±0.42 (range, 3-6) for osteoarthritis (P=0.064); and cup ARA score, 5.74±0.67 (range, 3-6) for AVN and 5.78±0.66 (range, 3-6) for osteoarthritis (P=0.344). Survival in this study was good and consistent with recent data on AVN, with no difference between AVN and osteoarthritis. Revisions for any cause or for dislocation were more common after THA for AVN. Functional outcomes were similar in the AVN and osteoarthritis groups. An anatomical cementless prosthesis combined with metal-on-metal 28-mm bearing provides durable good outcomes. III, non-randomized comparison of two prospective cohorts. Published by Elsevier Masson SAS.
New mouse model of skeletal muscle atrophy using spiral wire immobilization.
Onda, Akiko; Kono, Hajime; Jiao, Qibin; Akimoto, Takayuki; Miyamoto, Toshikazu; Sawada, Yasuhiro; Suzuki, Katsuhiko; Kusakari, Yoichiro; Minamisawa, Susumu; Fukubayashi, Toru
2016-10-01
Disuse-induced skeletal muscle atrophy is a serious concern; however, there is not an effective mouse model to elucidate the molecular mechanisms. We developed a noninvasive atrophy model in mice. After the ankle joints of mice were bandaged into a bilateral plantar flexed position, either bilateral or unilateral hindlimbs were immobilized by wrapping in bonsai steel wire. After 3, 5, or 10 days of immobilization of the hip, knee, and ankle, the weight of the soleus and plantaris muscles decreased significantly in both bilateral and unilateral immobilization. MAFbx/atrogin-1 and MuRF1 mRNA was found to have significantly increased in both muscles, consistent with disuse-induced atrophy. Notably, the procedure did not result in either edema or necrosis in the fixed hindlimbs. This method allows repeated, direct access to the immobilized muscle, making it a useful procedure for concurrent application and assessment of various therapeutic interventions. Muscle Nerve 54: 788-791, 2016. © 2016 Wiley Periodicals, Inc.
Massé-Alarie, Hugo; Beaulieu, Louis-David; Preuss, Richard; Schneider, Cyril
2015-02-01
Cross-sectional study of lumbopelvic muscle activation during rapid limb movements in chronic low back pain (CLBP) patients and healthy controls. Controversy exists over whether bilateral anticipatory activation of the deep abdominal muscles represents a normal motor control strategy prior to all rapid limb movements, or if this is simply a task-specific strategy appropriate for only certain movement conditions. To assess the onset timing of the transversus abdominis/internal oblique muscles (TrA/IO) during two rapid limb movement tasks with different postural demands - bilateral shoulder flexion in standing, unilateral hip extension in prone lying - as well as differences between CLBP and controls. Twelve CLBP and 13 controls performed the two tasks in response to an auditory cue. Surface EMG was acquired bilaterally from five muscles, including TrA/IO. In both groups, 50% of bilateral shoulder flexion trials showed bilateral anticipatory TrA/IO activation. This was rare, however, in unilateral hip extension for which only the TrA/IO contralateral to the moving leg showed anticipatory activation. The only significant difference in lumbo-pelvic muscle onset timing between CLBP and controls was a delay in semitendinosus activation during bilateral shoulder flexion in standing. Our data suggest that bilateral anticipatory TrA/IO activation is a task-specific motor control strategy, appropriate for only certain rapid limb movement conditions. Furthermore, the presence of altered semitendinosus onset timing in the CLBP group during bilateral shoulder flexion may be reflective of other possible lumbo-pelvic motor control alterations among this population. Copyright © 2014 Elsevier B.V. All rights reserved.
LOWER EXTREMITY KINEMATICS IN RUNNING ATHLETES WITH AND WITHOUT A HISTORY OF MEDIAL SHIN PAIN
Reiman, Michael P.
2012-01-01
Purpose/Background: Medial shin pain (MSP) is a common complaint that may stop an athlete from running. No previous study has identified deficits in pelvic, hip or knee motion as potential contributing factors to MSP. The purpose of this study was to investigate the differences in kinematics during running between uninjured athletes and those with MSP. Secondary analyses investigated differences in limbs between groups and differences between sexes. Methods: This case-control study investigated fourteen runners aged 18–40 years old with a history of unilateral MSP and fourteen runner controls. Three dimensional lower quarter kinematics were captured as runners ran on a treadmill. Specifically, peak hip internal rotation (IR), frontal plane pelvic tilt (PT) excursion, and knee flexion were examined. Results: Groups were similar in age, mass, height, and training mileage. Subjects with a history of MSP demonstrated significantly greater frontal plane PT (P = 0.002, Effect size = 0.55) and peak hip IR (P = 0.004, Effect size = 0.51); and less knee flexion (P = 0.02, Effect size = 0.46) than the control group. No significant difference was found in kinematics of the MSP group during their involved side stance phase as compared to their non-involved side. Conclusions: Runners with MSP displayed greater PT excursion, peak hip IR, and decreased knee flexion while running as compared to a control group. These results should help guide treatment for the running athlete that experiences MSP. Level of Evidence: 3b PMID:22893855
Lower extremity kinematics in running athletes with and without a history of medial shin pain.
Loudon, Janice K; Reiman, Michael P
2012-08-01
Medial shin pain (MSP) is a common complaint that may stop an athlete from running. No previous study has identified deficits in pelvic, hip or knee motion as potential contributing factors to MSP. The purpose of this study was to investigate the differences in kinematics during running between uninjured athletes and those with MSP. Secondary analyses investigated differences in limbs between groups and differences between sexes. This case-control study investigated fourteen runners aged 18-40 years old with a history of unilateral MSP and fourteen runner controls. Three dimensional lower quarter kinematics were captured as runners ran on a treadmill. Specifically, peak hip internal rotation (IR), frontal plane pelvic tilt (PT) excursion, and knee flexion were examined. Groups were similar in age, mass, height, and training mileage. Subjects with a history of MSP demonstrated significantly greater frontal plane PT (P = 0.002, Effect size = 0.55) and peak hip IR (P = 0.004, Effect size = 0.51); and less knee flexion (P = 0.02, Effect size = 0.46) than the control group. No significant difference was found in kinematics of the MSP group during their involved side stance phase as compared to their non-involved side. Runners with MSP displayed greater PT excursion, peak hip IR, and decreased knee flexion while running as compared to a control group. These results should help guide treatment for the running athlete that experiences MSP. 3b.
Phenotypic Variability of Osteogenesis Imperfecta Type V Caused by an IFITM5 Mutation
Shapiro, Jay R; Lietman, Caressa; Grover, Monica; Lu, James T; Nagamani, Sandesh CS; Dawson, Brian C; Baldridge, Dustin M; Bainbridge, Matthew N; Cohn, Dan H; Blazo, Maria; Roberts, Timothy T; Brennen, Feng-Shu; Wu, Yimei; Gibbs, Richard A; Melvin, Pamela; Campeau, Philippe M; Lee, Brendan H
2013-01-01
In a large cohort of osteogenesis imperfecta type V (OI type V) patients (17 individuals from 12 families), we identified the same mutation in the 5′ untranslated region (5′UTR) of the interferon-induced transmembrane protein 5 (IFITM5) gene by whole exome and Sanger sequencing (IFITM5 c.–14C > T) and provide a detailed description of their phenotype. This mutation leads to the creation of a novel start codon adding five residues to IFITM5 and was recently reported in several other OI type V families. The variability of the phenotype was quite large even within families. Whereas some patients presented with the typical calcification of the forearm interosseous membrane, radial head dislocation and hyperplastic callus (HPC) formation following fractures, others had only some of the typical OI type V findings. Thirteen had calcification of interosseous membranes, 14 had radial head dislocations, 10 had HPC, 9 had long bone bowing, 11 could ambulate without assistance, and 1 had mild unilateral mixed hearing loss. The bone mineral density varied greatly, even within families. Our study thus highlights the phenotypic variability of OI type V caused by the IFITM5 mutation. PMID:23408678
Predicting high blood metal ion concentrations following hip resurfacing.
Matharu, Gulraj S; Berryman, Fiona; Brash, Lesley; Pynsent, Paul B; Treacy, Ronan B C; Dunlop, David J
2015-01-01
To determine whether gender, femoral head size, acetabular inclination, and time since surgery predicted high blood metal ion concentrations following Birmingham Hip Resurfacing (BHR). BHR patients with unilateral bearings at one specialist centre with blood cobalt and chromium concentrations measured up to May 2013 were included. This comprised a mixed (at-risk) group including symptomatic patients and asymptomatic individuals with specific clinical and/or radiological findings. Blood sampling was at a mean of 7.5 years (range 1-15.4 years) postoperatively. Of 319 patients (mean age 49.3 years; 53% male), blood metal ions greater than 7 µg/l were observed in 9% (n = 28). Blood metal ions were significantly higher in females (p<0.001), femoral head sizes ≤48 mm (p<0.01), and cup inclinations >55° (p<0.001). Linear regression demonstrated femoral head size was responsible for the highest proportion of variance in blood metal ions (cobalt p<0.001, R2 = 8%; chromium p<0.001, R2 = 11%). Analysis of femoral head size and inclination together demonstrated 36% of BHRs with head sizes of 38-44 mm and inclination >55° had blood metal ions >7 µg/l. BHR 10-year survival for this at-risk group was 91% (95% confidence intervals 86.0%-95.0%) with 30 hips revised. If blood metal ions are used to screen hip resurfacing patients for adverse reactions to metal debris it is recommended those with small femoral head sizes (38-44 mm) and high acetabular inclinations (>55°) are targeted. These findings require validation in other cohorts as they may not be applicable to all hip resurfacing devices given the differences in radial clearance, coverage arc, and metallurgy.
Goker, Berna; Block, Joel A
2006-01-01
The risk of developing bilateral disease progressing to total hip arthroplasty (THA) among patients who undergo unilateral THA for non-traumatic avascular necrosis (AVN) remains poorly understood. An analysis of the time-course to contralateral THA, as well as the effects of underlying AVN risk factors, is presented. Forty-seven consecutive patients who underwent THA for AVN were evaluated. Peri-operative and annual post-operative antero-posterior pelvis radiographs were examined for evidence of contralateral involvement. Patient age, weight, height, underlying AVN risk factor(s), date of onset of contralateral hip pain if occurred, and date of contralateral THA if performed, were recorded. Bone scan, computerized tomography and magnetic resonance imaging data were utilized when available. Twenty-one patients (46.6%) underwent contralateral THA for AVN within a median of 9 months after the initial THA (range 0-93, interquartile range 28.5 months). The median follow-up for patients without contralateral THA was 75 months (range 3-109, interquartile range 69 months). Thirty-four patients had radiographic findings of contralateral AVN at study entry; 25 were symptomatic bilaterally at entry and 7 developed contralateral symptoms within a mean time of 12 months (median 10 months, interquartile range 12 months). None of the 13 patients who were free of radiographic evidence of contralateral AVN at study entry developed evidence of AVN during the follow-up. AVN associated with glucocorticoid use was more likely to manifest as bilateral disease than either idiopathic AVN or ethanol-associated AVN (P=0.02 and P=0.03 respectively). Radiographically-evident AVN in the contralateral hip at THA is unlikely to remain asymptomatic for a prolonged period of time. Conversely, asymptomatic contralateral hips without radiographic evidence of AVN are unlikely to develop clinically significant AVN.
Hébert-Losier, Kim; Schelin, Lina; Tengman, Eva; Strong, Andrew; Häger, Charlotte K
2018-03-01
Anterior cruciate ligament (ACL) ruptures may lead to knee dysfunctions later in life. Single-leg tasks are often evaluated, but bilateral movements may also be compromised. Our aim was to use curve analyses to examine double-leg drop-jump kinematics in ACL-reconstructed, ACL-deficient, and healthy-knee cohorts. Subjects with unilateral ACL ruptures treated more than two decades ago (17-28years) conservatively with physiotherapy (ACL PT , n=26) or in combination with reconstructive surgery (ACL R , n=28) and healthy-knee controls (n=25) performed 40-cm drop-jumps. Three-dimensional knee, hip, and trunk kinematics were analyzed during Rebound, Flight, and Landing phases. Curves were time-normalized and compared between groups (injured and non-injured legs of ACL PT and ACL R vs. non-dominant and dominant legs of controls) and within groups (between legs) using functional analysis of variance methods. Compared to controls, ACL groups exhibited less knee and hip flexion on both legs during Rebound and greater knee external rotation on their injured leg at the start of Rebound and Landing. ACL R also showed less trunk flexion during Rebound. Between-leg differences were observed in ACL R only, with the injured leg more internally rotated at the hip. Overall, kinematic curves were similar between ACL R and ACL PT . However, compared to controls, deviations spanned a greater proportion of the drop-jump movement at the hip in ACL R and at the knee in ACL PT . Trunk and bilateral leg kinematics during double-leg drop-jumps are still compromised long after ACL-rupture care, independent of treatment. Curve analyses indicate the presence of distinct compensatory mechanisms in ACL PT and ACL R compared to controls. Copyright © 2018 Elsevier B.V. All rights reserved.
Association Between Genetic Polymorphisms and Pain Sensitivity in Patients with Hip Osteoarthritis.
Olesen, Anne E; Nielsen, Lecia M; Feddersen, Søren; Erlenwein, Joachim; Petzke, Frank; Przemeck, Michael; Christrup, Lona L; Drewes, Asbjørn M
2018-06-01
Factors such as age, gender, and genetic polymorphisms may explain individual differences in pain phenotype. Genetic associations with pain sensitivity have previously been investigated in osteoarthritis patients, with a focus on the P2X7, TRPV1, and TACR1 genes. However, other genes may play a role as well. Osteoarthritis is a common joint disease, and many patients suffering from this disease are thought to have increased sensitivity to noxious stimuli resulting from sensitization in the nociceptive system. The aim of this study was to investigate if genetic variants of mu, kappa, and delta opioid receptor genes (OPRM1, OPRK1, and OPRD1) and the catechol-O-methyltransferase gene (COMT) influenced the pain phenotype in patients with osteoarthritis. The frequencies of 17 polymorphisms were examined. Pain sensitivity was assessed preoperatively by (1) hip rotation, (2) contact heat stimulation, (3) conditioned pain modulation effect, and (4) pressure stimulation at the tibia in both the affected and the unaffected leg. Ninety-two patients (mean age 66 years) with unilateral hip osteoarthritis were included in the study. Carriage of the OPRM1 rs589046T allele was found to be associated with increased pain ratings during hip rotation (P = 0.04) and increased conditioned pain modulation (P = 0.049). Carriage of the OPRD1 rs2234918C allele was found to be associated with an increased pain detection threshold to contact heat stimulation (P = 0.001). No other associations were found (all P > 0.05). Results from the present study suggest that, in patients with hip osteoarthritis, genetic variants in OPRM1 and OPRD1 may contribute to the pain phenotype. © 2017 World Institute of Pain.
Madara, Kathleen; Zeni, Joseph A
2017-01-01
Background and Purpose Most rehabilitation interventions after total hip arthroplasty (THA) are not designed to return patients to high-levels of physical activity and, thus, low levels of physical activity and residual weakness are common. The purpose of this case series was to describe the feasibility and preliminary efficacy of an exercise and education intervention for patients after THA who have already completed formal outpatient physical therapy. Study Design Case series Case Description Two participants underwent unilateral THA seven (case A) or eight (case B) months prior to the intervention. Individuals participated in 18 treatment sessions that included progressive aerobic and strengthening exercises and meetings with a health coach. Change in function, strength, and self-reported physical activity were measured. Outcomes 12 months after surgery were compared to a historical cohort of patients after THA. Outcome There were no adverse events during the intervention. At the end of the intervention, hip and knee strength on the surgical side increased approximately 30% compared to baseline in both cases. Activity level, and recreational performance, including walking up stairs and hiking uphill (case A), and running and golfing (case B), improved by the end of the intervention. Most changes were maintained at follow-up, although hip strength for case B decreased 27% after discharge from the intervention. Outcomes for both cases exceeded historical averages for patients 12 months after THA, with the exception of strength in case B. Discussion The exercise intervention was well tolerated and without negative effects in two participants. Both participants increased their ability to complete demanding recreational and sports-related activities, physical activity, and demonstrated improved hip abductor and knee extensor strength. Further research is needed to evaluate the implementation and effectiveness of similar interventions after THA. Level of Evidence Level 4 PMID:28515981
Selgrade, Brian P; Toney, Megan E; Chang, Young-Hui
2017-02-28
Locomotor adaptation is commonly studied using split-belt treadmill walking, in which each foot is placed on a belt moving at a different speed. As subjects adapt to split-belt walking, they reduce metabolic power, but the biomechanical mechanism behind this improved efficiency is unknown. Analyzing mechanical work performed by the legs and joints during split-belt adaptation could reveal this mechanism. Because ankle work in the step-to-step transition is more efficient than hip work, we hypothesized that control subjects would reduce hip work on the fast belt and increase ankle work during the step-to-step transition as they adapted. We further hypothesized that subjects with unilateral, trans-tibial amputation would instead increase propulsive work from their intact leg on the slow belt. Control subjects reduced hip work and shifted more ankle work to the step-to-step transition, supporting our hypothesis. Contrary to our second hypothesis, intact leg work, ankle work and hip work in amputees were unchanged during adaptation. Furthermore, all subjects increased collisional energy loss on the fast belt, but did not increase propulsive work. This was possible because subjects moved further backward during fast leg single support in late adaptation than in early adaptation, compensating by reducing backward movement in slow leg single support. In summary, subjects used two strategies to improve mechanical efficiency in split-belt walking adaptation: a CoM displacement strategy that allows for less forward propulsion on the fast belt; and, an ankle timing strategy that allows efficient ankle work in the step-to-step transition to increase while reducing inefficient hip work. Copyright © 2017 Elsevier Ltd. All rights reserved.
Lateral hip pain: findings from magnetic resonance imaging and clinical examination.
Woodley, Stephanie J; Nicholson, Helen D; Livingstone, Vicki; Doyle, Terence C; Meikle, Grant R; Macintosh, Janet E; Mercer, Susan R
2008-06-01
Prospective cross-sectional study. To examine the radiological and physical therapy diagnoses of lateral hip pain (LHP), and determine the validity of selected clinical variables for predicting gluteal tendon pathology. LHP is frequently encountered by clinicians. Further investigation is required to establish the specific pathologies implicated in the cause of LHP, and which clinical tests are useful in the assessment of this problem. Forty patients with unilateral LHP underwent a physical therapy examination followed by magnetic resonance imaging (MRI) studies. Three radiologists analyzed the images of both hips for signs of pathology. Interobserver reliability of the image analyses, the agreement between the physical therapy and radiological diagnoses, and the validity of the clinical tests were examined. Gluteus medius tendon pathology, bursitis, osteoarthritis and gluteal muscle atrophy (predominantly affecting gluteus minimus) were all implicated in the imaging report of LHP. While prevalent in symptomatic hips, abnormalities were also identified in asymptomatic hips, particularly relating to the diagnosis of bursitis. The strength of agreement between radiologists was variable and little agreement existed between the physical therapy and radiological diagnoses of pathology. Nine of the 26 clinical variables examined in relation to gluteal tendon pathology had likelihood ratios above 2.0 or below 0.5, but the associated 95% confidence intervals were large. The diagnosis of LHP is challenging and our results highlight some problems associated with the use of MRI as a diagnostic reference standard. This factor, together with the imprecise point estimates of the likelihood ratios, means that no firm conclusions can be made regarding the diagnostic utility of the clinical tests used in the assessment of gluteal tendon pathology.
Charlton, Paula C; Mentiplay, Benjamin F; Grimaldi, Alison; Pua, Yong-Hao; Clark, Ross A
2017-02-01
Firstly to describe the reliability of assessing maximal isometric strength of the hip abductor and adductor musculature using a hand held dynamometry (HHD) protocol with simultaneous wireless surface electromyographic (sEMG) evaluation of the gluteus medius (GM) and adductor longus (AL). Secondly, to describe the correlation between isometric strength recorded with the HHD protocol and a laboratory standard isokinetic device. Reliability and correlational study. A sample of 24 elite, male, junior, rugby league athletes, age 16-20 years participated in repeated HHD and isometric Kin-Com (KC) strength testing with simultaneous sEMG assessment, on average (range) 6 (5-7) days apart by a single assessor. Strength tests included; unilateral hip abduction (ABD) and adduction (ADD) and bilateral ADD assessed with squeeze (SQ) tests in 0 and 45° of hip flexion. HHD demonstrated good to excellent inter-session reliability for all outcome measures (ICC (2,1) =0.76-0.91) and good to excellent association with the laboratory reference KC (ICC (2,1) =0.80-0.88). Whilst intra-session, inter-trial reliability of EMG activation and co-activation outcome measures ranged from moderate to excellent (ICC (2,1) =0.70-0.94), inter-session reliability was poor (all ICC (2,1) <0.50). Isometric strength testing of the hip ABD and ADD musculature using HHD may be measured reliably in elite, junior rugby league athletes. Due to the poor inter-session reliability of sEMG measures, it is not recommended for athlete screening purposes if using the techniques implemented in this study. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
2011-01-01
ABSTRACT Purpose: The purpose of this case study is to describe the management of a female patient with chronic left low back pain and sacroiliac joint pain (LBP/SIJP) using unique unilateral exercises developed by the Postural Restoration Institute (PRI) to address pelvic asymmetry and left hip capsule restriction, which is consistent with a Right Handed and Left Anterior Interior Chain pattern of postural asymmetry. Client Description: The client was 65-year-old woman with a 10-month history of constant left LBP/SIJP and leg pain. Intervention: The patient was seen six times to correct pelvic position/posture and left hip posterior capsule restriction via (1) muscle activation (left hamstrings, adductor magnus, and anterior gluteus medius) and (2) left hip adduction to lengthen the left posterior capsule/ischiofemoral ligament. Stabilization exercises included bilateral hamstrings, gluteus maximus, adductors, and abdominals to maintain pelvic position/posture. Measures and Outcome: Left Ober's test (initially positive) was negative at discharge. Pain as measured on the Numeric Pain Rating Scale (initially 1/10 at best and 8/10 at worst) was 0/10–0/10 at discharge. Oswestry Disability Index score (initially 20%) was 0% at discharge. The patient no longer had numbness in her left leg, and sexual intercourse had become pain free. Implications: Interventions to restore and maintain the optimal position of pelvis and hip (femoral head in the acetabulum) may be beneficial for treating patients with chronic LBP/SIJP. The patient's pain was eliminated 13 days after she first performed three exercises to reposition the pelvis and restore left posterior hip capsule extensibility and internal rotation. PMID:22379254
[Bone surgery for unstable hips in patients with cerebral palsy].
Poul, J; Pesl, M; Pokorná, M
2004-01-01
The aim of this retrospective study was to compare the efficacy of femoral osteotomy alone with that of osteotomy combined with an acetabular procedure in patients with unstable hips due to spastic cerebral palsy. Sixty-one hip joints in 50 patients who had shown distinct subluxation or dislocation of the joint were operated on. Eleven patients underwent bilateral surgery. Before bone surgery, soft-tissue release involving both the flexors and adductors was performed on 19 hips. Femoral osteotomy alone was performed on 29 hip joints and combined femoral and pelvic osteotomy was carried out on 32 joints.Twelve resections of the proximal femur in seven patients were evaluated as a separate group. All treated hip joints were assessed by clinical and radiographic examination at a follow-up of more than 5 years. The skiagraphs taken in a strictly neutral position of the lower limbs before surgery and at the final examination were evaluated on the basis of Reimers's migration index and Wiberg's centre-edge angle. The locomotor abilities of each child were categorized according to the Vojta scoring system for locomotor development. The range of motion in the treated hip joint was assessed using the standard S. F. T. R. method. The results obtained were statistically analyzed by the Kruskal- Wallis, one-way ANOVA test. A comparison of the results of femoral osteotomy alone with those of combined femoral and pelvic osteotomy showed that the post-operative values of the migration index and centre-edge angle, as compared with the pre-operative ones, were statistically higher (p<0.05) in the latter. In a long-term perspective, the surgery had no adverse effects on a natural development of locomotor abilities of the child. The children had higher scores by the modified Vojta rating system. There was no change in the range of motion in the treated hip joints after the operation. In 28, out of the 32 joints treated by combined femoral and pelvic osteotomy, Salter osteotomy was performed and it showed a high efficacy in providing hip joint stability. The main emphasis during surgery was placed on the maximum acetabular rotation laterally. Femoral osteotomy alone was less effective in providing hip joint stability; in addition, in order to achieve this, tilting of the proximal fragment to a varus position was generally higher than in combined operations. In three patients this treatment resulted in fixed adduction of the hip joint with negative consequences for movement. In the treatment of unstable hip joints a combination of varus derotation femoral osteotomy and pelvic osteotomy provides better containment of the joint than femoral osteotomy alone.
Markström, Jonas L; Tengman, Eva; Häger, Charlotte K
2018-02-01
Little is known regarding movement strategies in the long term following injury of the anterior cruciate ligament (ACL), and even less about comparisons of reconstructed and deficient knees in relation to healthy controls. The present purpose was to compare trunk, hip, and knee kinematics during a one-leg vertical hop (VH) ~20 years post-ACL injury between persons treated with surgery and physiotherapy (ACL R ), solely physiotherapy (ACL PT ), and controls (CTRL). Between-leg kinematic differences within groups were also investigated. Sixty-six persons who suffered unilateral ACL injury on average 23 ± 2 years ago (32 ACL R , 34 ACL PT ) and 33 controls performed the VH. Peak trunk, hip, and knee angles during Take-off and Landing phases recorded with a 3D motion capture system were analysed with multivariate statistics. Significant group effects during both Take-off and Landing were found, with ACL PT differing from CTRL in Take-off with a combination of less knee flexion and knee internal rotation, and from both ACL R and CTRL in Landing with less hip and knee flexion, knee internal rotation, and greater hip adduction. ACL R also presented different kinematics to ACL PT and CTRL in Take-off with a combination of greater trunk flexion, hip flexion, hip internal rotation, and less knee abduction, and in Landing with greater trunk flexion and hip internal rotation. Further, different kinematics and hop height were found between legs within groups in both Take-off and Landing for both ACL groups, but not for CTRL. Different kinematics for the injured leg for both ACL groups compared to CTRL and between treatment groups, as well as between legs within treatment groups, indicate long-term consequences of injury. Compensatory mechanisms for knee protection seem to prevail over time irrespective of initial treatment, possibly increasing the risk of re-injury and triggering the development of osteoarthritis. Detailed investigation of movement strategies during the VH provides important information and a more comprehensive evaluation of knee function than merely hop height. More attention should also be given to the trunk and hip in clinics when evaluating movement strategies after ACL injury. Prospective cohort study, Level II.
Prosthetic ankle push-off work reduces metabolic rate but not collision work in non-amputee walking.
Caputo, Joshua M; Collins, Steven H
2014-12-03
Individuals with unilateral below-knee amputation expend more energy than non-amputees during walking and exhibit reduced push-off work and increased hip work in the affected limb. Simple dynamic models of walking suggest a possible solution, predicting that increasing prosthetic ankle push-off should decrease leading limb collision, thereby reducing overall energy requirements. We conducted a rigorous experimental test of this idea wherein ankle-foot prosthesis push-off work was incrementally varied in isolation from one-half to two-times normal levels while subjects with simulated amputation walked on a treadmill at 1.25 m · s(-1). Increased prosthesis push-off significantly reduced metabolic energy expenditure, with a 14% reduction at maximum prosthesis work. In contrast to model predictions, however, collision losses were unchanged, while hip work during swing initiation was decreased. This suggests that powered ankle push-off reduces walking effort primarily through other mechanisms, such as assisting leg swing, which would be better understood using more complete neuromuscular models.
Prosthetic ankle push-off work reduces metabolic rate but not collision work in non-amputee walking
NASA Astrophysics Data System (ADS)
Caputo, Joshua M.; Collins, Steven H.
2014-12-01
Individuals with unilateral below-knee amputation expend more energy than non-amputees during walking and exhibit reduced push-off work and increased hip work in the affected limb. Simple dynamic models of walking suggest a possible solution, predicting that increasing prosthetic ankle push-off should decrease leading limb collision, thereby reducing overall energy requirements. We conducted a rigorous experimental test of this idea wherein ankle-foot prosthesis push-off work was incrementally varied in isolation from one-half to two-times normal levels while subjects with simulated amputation walked on a treadmill at 1.25 m.s-1. Increased prosthesis push-off significantly reduced metabolic energy expenditure, with a 14% reduction at maximum prosthesis work. In contrast to model predictions, however, collision losses were unchanged, while hip work during swing initiation was decreased. This suggests that powered ankle push-off reduces walking effort primarily through other mechanisms, such as assisting leg swing, which would be better understood using more complete neuromuscular models.
Prosthetic ankle push-off work reduces metabolic rate but not collision work in non-amputee walking
Caputo, Joshua M.; Collins, Steven H.
2014-01-01
Individuals with unilateral below-knee amputation expend more energy than non-amputees during walking and exhibit reduced push-off work and increased hip work in the affected limb. Simple dynamic models of walking suggest a possible solution, predicting that increasing prosthetic ankle push-off should decrease leading limb collision, thereby reducing overall energy requirements. We conducted a rigorous experimental test of this idea wherein ankle-foot prosthesis push-off work was incrementally varied in isolation from one-half to two-times normal levels while subjects with simulated amputation walked on a treadmill at 1.25 m·s−1. Increased prosthesis push-off significantly reduced metabolic energy expenditure, with a 14% reduction at maximum prosthesis work. In contrast to model predictions, however, collision losses were unchanged, while hip work during swing initiation was decreased. This suggests that powered ankle push-off reduces walking effort primarily through other mechanisms, such as assisting leg swing, which would be better understood using more complete neuromuscular models. PMID:25467389
Chen, Tao; Shang, Xifu; He, Rui; Hu, Fei; Ge, Chang
2012-03-01
To investigate the method to avoid lengthening lower limbs after total hip arthroplasty in patients with congenital short femoral neck. The clinical data were analyzed retrospectively from 38 patients undergoing unilateral total hip arthroplasty between April 2005 and December 2010. There were 26 males and 12 females, aged 45-78 years (mean, 62.3 years). Among these cases, there were 11 cases of avascular necrosis of the femoral head, 17 cases of hip osteoarthritis, and 10 cases of femoral neck fracture. Before operation, 29 cases had leg length discrepancy; and the shortened length of the legs was 10-24 mm with an average of 14.5 mm by clinical measurement, and was 11-25 mm with an average of 14.7 mm by X-ray film measurement. The Harris score before operation was 44.0 +/- 3.6. At 1 day after operation, 3 cases had legs lengthening by clinical and X-ray film measurement; limb length difference less than 10 mm was regarded as equal limb length in the other 35 patients (92.1%). All incisions healed by first intention, and no complication of infection or lower limb deep venous thrombosis occurred. In 3 patients who had legs lengthening, 1 patient had abnormal gait and slight limping after increasing heel pad because the lower limb was lengthened by 16 mm, and 2 patients had slight limping. The other patients could walk normally and achieved pain relief of hip. Thirty-six patients were followed up 12-68 months (mean, 43.8 months). The Harris score was 86.7 +/- 2.3 after 6 months, showing significant difference (t = 3.260, P = 0.031) when compared with that before operation. The X-ray films showed no prosthetic loosening or subsidence. For patients with congenital short femoral neck during total hip arthroplasty, the surgeons should pay attention to osteotomy plane determination, limb length measurement, and use of the prosthesis with collar to avoid the lengthening lower limbs.
Bell, David R.; Blackburn, J. Troy; Hackney, Anthony C.; Marshall, Stephen W.; Beutler, Anthony I.; Padua, Darin A.
2014-01-01
Context: Of the individuals able to return to sport participation after an anterior cruciate ligament(ACL) injury, up to 25% will experience a second ACL injury. This population may be more sensitive to hormonal fluctuations, which may explain this high rate of second injury. Objective: To examine changes in 3-dimensional hip and knee kinematics and kinetics during a jump landing and to examine knee laxity across the menstrual cycle in women with histories of unilateral noncontact ACL injury. Design Controlled laboratory study. Setting: Laboratory. Patients or Other Participants: A total of 20 women (age = 19.6 ± 1.3 years, height = 168.6 ± 5.3 cm, mass = 66.2 ± 9.1 kg) with unilateral, noncontact ACL injuries. Intervention(s) Participants completed a jump-landing task and knee-laxity assessment 3 to 5 days after the onset of menses and within 3 days of a positive ovulation test. Main Outcome Measure(s): Kinematics in the uninjured limb at initial contact with the ground during a jump landing, peak kinematics and kinetics during the loading phase of landing, anterior knee laxity via the KT-1000, peak vertical ground reaction force, and blood hormone concentrations (estradiol-β-17, progesterone, free testosterone). Results: At ovulation, estradiol-β-17 (t = −2.9, P = .009), progesterone (t = −3.4, P = .003), and anterior knee laxity (t = −2.3, P = .03) increased, and participants presented with greater knee-valgus moment (Z = −2.6, P = .01) and femoral internal rotation (t = −2.1, P = .047). However, during the menses test session, participants landed harder (greater peak vertical ground reaction force; t = 2.2, P = .04), with the tibia internally rotated at initial contact (t = 2.8, P = .01) and greater hip internal-rotation moment (Z = −2.4, P = .02). No other changes were observed across the menstrual cycle. Conclusions Knee and hip mechanics in both phases of the menstrual cycle represented a greater potential risk of ACL loading. Observed changes in landing mechanics may explain why the risk of second ACL injury is elevated in this population. PMID:24568229
High-impact sport after hip resurfacing: The Ironman triathlon.
Girard, J; Lons, A; Pommepuy, T; Isida, R; Benad, K; Putman, S
2017-09-01
Returning to high-impact sport is an increasingly frequent functional demand following hip replacement. The literature, however, is sparse on the subject and nonexistent regarding triathlon. We therefore conducted a retrospective study of hip resurfacing in triathlon players, to determine: (1) whether it is possible to return to this kind of sport; (2) if so, whether it is possible to return to the same level; and (3) how a resurfaced hip behaves under these conditions. Hip resurfacing allows return to competition level in long-distance triathlon. A single-center single-operator retrospective study included patients undergoing hip resurfacing with the Conserve Plus implant inserted through a posterolateral approach, who had ceased long-distance triathlon practice due to osteoarthritis of the hip. Fifty-one of the 1688 patients undergoing resurfacing during the inclusion period were long-distance triathlon players. The series comprised 48 patients: 51 implants; 43 male, 5 female; mean age, 44.8 years (range, 28.2-58.9 years). At a mean 4.7 years' follow-up (range, 2.2-7.6 years), all clinical scores showed significant improvement; Merle d'Aubigné and Harris scores rose respectively from 12.3 (5-16) and 42 (37-56) preoperatively to 17.5 (13-18) and 93.2 (73-100) (P<0.001). There were no cases of dislocation or implant revision. Forty-five patients returned to sport (94%). Rates of return to swimming, cycling and running were respectively 38/48 (79%), 41/48 (85%) and 33/48 (69%). Preoperatively, all patients had taken part in at least 1 competition: 29 with distance=70.3km and 19 with distance=140.6km. At follow-up, 28 patients had taken part in an Ironman competition: 21 with distance=70.3km and 7 with distance=140.6km. Mean competition performance did not differ between pre and postoperative periods. Return-to-sport rates were good following hip resurfacing. Non-impact sports (swimming, cycling) predominated postoperatively, whereas the rate of impact sport (running) diminished. Return to competition-level sport (extreme triathlon) was possible for 28/48 patients (58%). Implant survival seemed unaffected by this high-impact sports activity at a mean 4.7 years' follow-up. IV, retrospective, non-controlled. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Terrier, Alexandre; Latypova, Adeliya; Guillemin, Maika; Parvex, Valérie; Guyen, Olivier
2017-03-01
Constrained devices, standard implants with large heads, and dual mobility systems have become popular options to manage instability after total hip arthroplasty (THA). Clinical results with these options have shown variable success rates and significant higher rates of aseptic loosening and mechanical failures with constrained implants. Literature suggests potential advantages of dual mobility, however little is known about its biomechanics. We present a comparative biomechanical study of a standard implant, a constrained implant, and a dual mobility system. A finite element analysis was developed to assess and compare these acetabular options with regard to the range of motion (ROM) to impingement, the angle of dislocation, the resistive torque, the volume of polyethylene (PE) with a stress above 80% of the elastic limit, and the interfacial cup/bone stress. Dual mobility implants provided the greatest ROM to impingement and allowed delaying subluxation and dislocation when compared to standard and constrained implants. Dual mobility also demonstrated the lowest resistive torque at subluxation while the constrained implant provided the greatest one. The lowest critical PE volume was observed with the dual mobility implant, and the highest stress at the interfaces was observed with the constrained implant. This study highlights the biomechanical advantages of dual mobility systems over constrained and standard implants, and is supported by the clinical results reported. Therefore, the use of dual mobility systems in situations at risk for instability should be advocated and constrained implants should be restricted to salvage situations.
Gonzalez Della Valle, Alejandro; Blanes Perez, Alvaro; Lee, Yuo-Yu; Saboeiro, Gregory R; Konin, Gabrielle P; Endo, Yoshimi; Sharrock, Nigel E; Salvati, Eduardo A
2017-04-01
In the event of a postoperative pulmonary embolism (PE), it is generally believed that patients with centrally located emboli will have worse clinical symptoms than those with segmental or subsegmental ones. We studied if a relationship exists between the clinical severity at the time of PE diagnosis and the location of the emboli within the pulmonary vasculature. All 269 patients who developed an in-hospital, computed tomography pulmonary angiography-proved, PE following elective total hip arthroplasty or total knee arthroplasty in our institution were studied. The clinical severity of the PE was calculated using the Pulmonary Embolism Severity Index (PESI) that classifies patients in 5 classes (class 5: most severe). All computed tomography pulmonary angiographies were re-reviewed to determine the location of the emboli within the pulmonary vasculature (central, segmental, or subsegmental-unilateral or bilateral). The association between PESI and the PE location was examined. The most proximal location of the emboli was central in 62, segmental in 139, and subsegmental in 68. There were 180 unilateral and 89 bilateral PE patients. There was no association between the PESI and the location of the emboli within the pulmonary vasculature (P = .32). Patients with bilateral or unilateral lung involvement had similar PESI (P = .78). The PESI, a recognized, validated predictor of mortality after PE was similar in patients with central, segmental, or subsegmental PE; and in patients with unilateral or bilateral lung involvement. The present study may aid clinicians while assessing and discussing the severity of PE symptoms with patients at the time of diagnosis. Copyright © 2016 Elsevier Inc. All rights reserved.
Hornby, T George; Kinnaird, Catherine R; Holleran, Carey L; Rafferty, Miriam R; Rodriguez, Kelly S; Cain, Julie B
2012-10-01
Robotic-assisted locomotor training has demonstrated some efficacy in individuals with neurological injury and is slowly gaining clinical acceptance. Both exoskeletal devices, which control individual joint movements, and elliptical devices, which control endpoint trajectories, have been utilized with specific patient populations and are available commercially. No studies have directly compared training efficacy or patient performance during stepping between devices. The purpose of this study was to evaluate kinematic, electromyographic (EMG), and metabolic responses during elliptical- and exoskeletal-assisted stepping in individuals with incomplete spinal cord injury (SCI) compared with therapist-assisted stepping. Design A prospective, cross-sectional, repeated-measures design was used. Participants with incomplete SCI (n=11) performed 3 separate bouts of exoskeletal-, elliptical-, or therapist-assisted stepping. Unilateral hip and knee sagittal-plane kinematics, lower-limb EMG recordings, and oxygen consumption were compared across stepping conditions and with control participants (n=10) during treadmill stepping. Exoskeletal stepping kinematics closely approximated normal gait patterns, whereas significantly greater hip and knee flexion postures were observed during elliptical-assisted stepping. Measures of kinematic variability indicated consistent patterns in control participants and during exoskeletal-assisted stepping, whereas therapist- and elliptical-assisted stepping kinematics were more variable. Despite specific differences, EMG patterns generally were similar across stepping conditions in the participants with SCI. In contrast, oxygen consumption was consistently greater during therapist-assisted stepping. Limitations Limitations included a small sample size, lack of ability to evaluate kinetics during stepping, unilateral EMG recordings, and sagittal-plane kinematics. Despite specific differences in kinematics and EMG activity, metabolic activity was similar during stepping in each robotic device. Understanding potential differences and similarities in stepping performance with robotic assistance may be important in delivery of repeated locomotor training using robotic or therapist assistance and for consumers of robotic devices.
Lungu, Eugen; Vendittoli, Pascal-André; Desmeules, François
2015-10-05
The ability to predict preoperatively the identity of patients undergoing hip arthroplasty at risk of suboptimal outcomes could help implement interventions targeted at improving surgical results. The objective was to develop a preliminary prediction algorithm (PA) allowing the identification of patients at risk of unsatisfactory outcomes one to two years following hip arthroplasty. Retrospective data on a cohort of 265 patients having undergone primary unilateral hip replacement (188 total arthroplasties and 77 resurfacing arthroplasties) from 2004 to 2010 were collected from our arthroplasty database. Hip pain and function, as measured by the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) were collected, as well as self-reported hip joint perception after surgery. Demographic and clinical variables recorded at the time of the surgery were considered as potential predictors. Patients were considered as having a suboptimal surgical outcome if they were in the worst quartile of the postoperative total WOMAC score and perceived their operated hip as artificial with minimal or major limitations. The PA was developed using recursive partitioning. Mean postoperative surgical follow-up was 446 ± 171 days. Forty patients (15.1 %) had a postoperative total WOMAC score in the worst quartile (>11.5/100) and perceived their joint as artificial with minimal or major restrictions. A PA consisting of the following variables achieved the most acceptable level of prediction: gender, age at the time of surgery, body mass index (BMI), and three items of the preoperative WOMAC (degree of pain with walking on a flat surface and during the night as well as degree of difficulty with putting socks or stockings). The rule had a sensitivity of 75.0 % (95 % CI: 59.8-85.8), a specificity of 77.8 % (95 % CI: 71.9-82.7), a positive predictive value of 37.5 % (95 % CI: 27.7-48.5), a negative predictive value of 94.6 % (95 % CI: 90.3-97.0) and positive and negative likelihood ratios of 3.38 (95 % CI: 2.49-4.57) and 0.34 (95 % CI: 0.19-0.55) respectively. The preliminary PA shows promising results at identifying patients at risk of significant functional limitations, increased pain and inadequate joint perception after hip arthroplasty. Clinical use should not be implemented before additional validation and refining.
Cushman, Daniel; Rho, Monica E
2015-07-01
Case report. Proximal hamstring tendinopathy in runners is characterized by pain with passive hip flexion with the knee extended, active hip extension, and pain with sitting. Relatively little literature exists on the condition, and publications on nonsurgical treatment protocols are even more scarce. Surgical intervention, which comprises the majority of literature for treatment of this condition, is an option for cases that fail to respond to nonsurgical treatment. The patient was a 34-year-old, otherwise healthy male triathlete with unilateral proximal hamstring tendinopathy diagnosed by ultrasound, who had pain only with running and prolonged sitting. After he failed to respond to 4 weeks of eccentric knee flexion and lumbopelvic musculature strengthening exercises, an eccentric hip extensor strengthening program using a treadmill was initiated. This treadmill exercise was performed on a daily basis, in addition to a lumbopelvic musculature strengthening program. The patient noted a decrease in pain within 2 weeks of initiating the new exercise, and was able to return to gradual running after 4 weeks and to speed training after 12 weeks. He returned to competition shortly thereafter and had no recurrence for 12 months after the initiation of therapy. His score on the Victorian Institute of Sport Assessment-proximal hamstring tendons improved from 23 on initial presentation to 83 at 12 weeks after the initiation of therapy. We described the management of a triathlete with subacute proximal hamstring tendinopathy, who responded well to nonsurgical treatment using eccentric hip extension strengthening using a treadmill. Therapy, level 4.
CUSHMAN, DANIEL; RHO, MONICA E.
2015-01-01
STUDY DESIGN Case report. BACKGROUND Proximal hamstring tendinopathy in runners is characterized by pain with passive hip flexion with the knee extended, active hip extension, and pain with sitting. Relatively little literature exists on the condition, and publications on nonsurgical treatment protocols are even more scarce. Surgical intervention, which comprises the majority of literature for treatment of this condition, is an option for cases that fail to respond to nonsurgical treatment. CASE DESCRIPTION The patient was a 34-year-old, otherwise healthy male triathlete with unilateral proximal hamstring tendinopathy diagnosed by ultrasound, who had pain only with running and prolonged sitting. After he failed to respond to 4 weeks of eccentric knee flexion and lumbopelvic musculature strengthening exercises, an eccentric hip extensor strengthening program using a treadmill was initiated. This treadmill exercise was performed on a daily basis, in addition to a lumbopelvic musculature strengthening program. OUTCOMES The patient noted a decrease in pain within 2 weeks of initiating the new exercise, and was able to return to gradual running after 4 weeks and to speed training after 12 weeks. He returned to competition shortly thereafter and had no recurrence for 12 months after the initiation of therapy. His score on the Victorian Institute of Sport Assessment-proximal hamstring tendons improved from 23 on initial presentation to 83 at 12 weeks after the initiation of therapy. DISCUSSION We described the management of a triathlete with subacute proximal hamstring tendinopathy, who responded well to nonsurgical treatment using eccentric hip extension strengthening using a treadmill. LEVEL OF EVIDENCE Therapy, level 4. PMID:25996362
Barlow, Brian T; Ortiz, Philippe A; Boles, John W; Lee, Yuo-Yu; Padgett, Douglas E; Westrich, Geoffrey H
2017-05-01
The recent experiences with adverse local tissue reactions have highlighted the need to establish what are normal serum levels of cobalt (Co), chromium (Cr), and titanium (Ti) after hip arthroplasty. Serum Co, Cr, and Ti levels were measured in 80 nonconsecutive patients with well-functioning unilateral total hip arthroplasty and compared among 4 bearing surfaces: ceramic-on-ceramic (CoC); ceramic-on-polyethylene (CoP); metal-on-polyethylene (MoP), and dual mobility (DM). The preoperative and most recent University of California, Los Angeles (UCLA) and Western Ontario and McMaster Universities Arthritis Index (WOMAC) scores were compared among the different bearing surfaces. No significant difference was found among serum Co and Cr levels between the 4 bearing surface groups (P = .0609 and P = .1577). Secondary analysis comparing metal and ceramic femoral heads demonstrated that the metal group (MoP, modular dual mobility (Stryker Orthopedics, Mahwah, NJ) [metal]) had significant higher serum Co levels compared with the ceramic group (CoC, CoP, MDM [ceramic]) (1.05 mg/L ± 1.25 vs 0.59 mg/L ± 0.24; P = .0411). Spearman coefficient identified no correlation between metal ion levels and patient-reported outcome scores. No serum metal ion level differences were found among well-functioning total hip arthroplasty with modern bearing couples. Significantly higher serum Co levels were seen when comparing metal vs ceramic femoral heads in this study and warrants further investigation. Metal ion levels did not correlate with patient-reported outcome measures. Copyright © 2016 Elsevier Inc. All rights reserved.
[Trochanteric femoral fractures: anatomy, biomechanics and choice of implants].
Bonnaire, F; Lein, T; Bula, P
2011-06-01
The objective of any surgical care of a trochanteric femoral fracture should be the achievement of a stable osteosynthesis that allows early full weight-bearing mobilisation of the patient, because long-term immobilisation soon becomes a vital threat to the affected patients who are usually elderly with correlating comorbidities. The anatomical references of the proximal femur and the structure of the hip joint contain some specifics that play an essential role in the incurrence of a trochanteric femoral fracture and the planning of the osteosynthesis as well. With reposition and fracture stabilisation particular importance must be attached to the collo-diaphyseal and the antetorsion angle so that they do not interfere with the functional interaction of the hip and knee joint. Uncomplex trochanteric fractures ordinarily stabilise sufficiently after reposition so that even an extramedullary implant can ensure full weight-bearing stability. With evermore distal fracture course and intertrochanteric comminution zone, rotational instability and pivot transfer of the fracture area to lateral and caudal are followed by an increase of the dislocating forces. These kinds of fractures (A2 and A3 according to the AO/ASIF classification) profit from an intramedullary and rotationally stable osteosynthesis. Basically primary total hip arthroplasty is a potential option for surgical care of a trochanteric fracture in elderly patients with relevant coxarthrosis. However this procedure can only be recommended in cases of a stable uncomplex fracture. The more the medial interlocking of the proximal femur is destroyed the more difficult it will be to primarily implant a total hip prosthesis with good offset and without a varus and rotational failure in the fracture zone.The current studies in the main show disadvantages due to increased complications in these patients, so that in cases of an unstable trochanteric fracture a primary osteosynthesis should be performed followed by total hip arthroplasty after fracture consolidation has occurred.
Cukiert, Arthur; Cukiert, Cristine Mella; Argentoni-Baldochi, Meire; Baise, Carla; Forster, Cássio Roberto; Mello, Valeria Antakli; Burattini, José Augusto; Lima, Alessandra Moura
2011-12-01
Deep brain stimulation (DBS) has been used in an increasing frequency for treatment of refractory epilepsy. Acute deep brain macrostimulation intraoperative findings were sparsely published in the literature. We report on our intraoperative macrostimulation findings during thalamic and hippocampal DBS implantation. Eighteen patients were studied. All patients underwent routine pre-operative evaluation that included clinical history, neurological examination, interictal and ictal EEG, high resolution 1.5T MRI and neuropsychological testing. Six patients with temporal lobe epilepsy were submitted to hippocampal DBS (Hip-DBS); 6 patients with focal epilepsy were submitted to anterior thalamic nucleus DBS (AN-DBS) and 6 patients with generalized epilepsy were submitted to centro-median thalamic nucleus DBS (CM-DBS). Age ranged from 9 to 40 years (11 males). All patients were submitted to bilateral quadripolar DBS electrode implantation in a single procedure, under general anesthesia, and intraoperative scalp EEG monitoring. Final electrode's position was checked postoperatively using volumetric CT scanning. Bipolar stimulation using the more proximal and distal electrodes was performed. Final standard stimulation parameters were 6Hz, 4V, 300μs (low frequency range: LF) or 130Hz, 4V, 300μs (high frequency range: HF). Bilateral recruiting response (RR) was obtained after unilateral stimulation in all patients submitted to AN and CM-DBS using LF stimulation. RR was widespread but prevailed over the fronto-temporal region bilaterally, and over the stimulated hemisphere. HF stimulation led to background slowing and a DC shift. The mean voltage for the appearance of RR was 4V (CM) and 3V (AN). CM and AN-DBS did not alter inter-ictal spiking frequency or morphology. RR obtained after LF Hip-DBS was restricted to the stimulated temporal lobe and no contralateral activation was noted. HF stimulation yielded no visually recognizable EEG modification. Mean intensity for initial appearance of RR was 3V. In 5 of the 6 patients submitted to Hip-DBS, an increase in inter-ictal spiking was noted unilaterally immediately after electrode insertion. Intraoperative LF stimulation did not modify temporal lobe spiking; on the other hand, HF was effective in abolishing inter-ictal spiking in 4 of the 6 patients studied. There was no immediate morbidity or mortality in this series. Macrostimulation might be used to confirm that the hardware was working properly. There was no typical RR derived from each studied thalamic nuclei after LF stimulation. On the other hand, absence of such RRs was highly suggestive of hardware malfunction or inadequate targeting. Thalamic-DBS (Th-DBS) RR was always bilateral after unilateral stimulation, although they somehow prevailed over the stimulated hemisphere. Contrary to Th-DBS, Hip-DBS gave rise to localized RR over the ipsolateral temporal neocortex, and absence of this response might very likely be related to inadequate targeting or hardware failure. Increased spiking was seen over temporal neocortex during hippocampal electrode insertion; this might point to the more epileptogenic hippocampal region in each individual patient. We did not notice any intraoperative response difference among patients with temporal lobe epilepsy with or without MTS. The relationship between these intraoperative findings and seizure outcome is not yet clear and should be further evaluated. 2011 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.
[Characteristics in treatment of the hip in patients with Down syndrome].
Peterlein, C-D; Schiel, M; Timmesfeld, N; Schofer, M D; Eberhardt, O; Wirth, T; Fernandez, F F
2013-12-01
The treatment of hip instability in patients with Down syndrome is challenging. We have performed different pelvic osteotomies and corrections at the proximal femur for this indication. This retrospective study was conducted to evaluate the clinical and radiological outcome of each intervention. All in all, 166 patients with Down syndrome were treated at our orthopaedic department in the observation period. Problems related to the hip joint were diagnosed in 63 of those patients. Only patients who underwent surgery were included in this study. The charts and X-rays of these 31 patients were evaluated with respect to the following parameters: incidence of the hip problem, concomitant diseases, temporal progress, kind of operation method and date, duration of stay in the hospital, after-care, follow-on surgery related to complications, AC angle, CE angle, ACM angle, CCD angle, index of migration according to Reimers, classification of Bauer and Kerschbauer and general morphology of the femoral head. The group was compared with an age-matched group of 21 patients with hip dysplasia. Those patients underwent the same sort of operation in the same year. In the Morbus Down group, we performed surgery for preservation of the hip in 49 cases. This included 13 osteotomies according to Chiari, 11 triple osteotomies according to Tönnis, 10 corrections by femoral varus derotation osteotomy, 8 pelvic osteotomies according to Pemberton, 5 pelvic osteotomies according to Salter and 2 open reductions of the hip. With respect to the moment of surgery, we detected three peaks of age. There was no difference in course of disease and quantity of complications between the groups. Satisfactory results concerning clinical and radiological outcome were achieved predominantly by complete redirectional acetabular osteotomies. Half of the patients who were solely treated by femoral varus derotation osteotomy needed follow-on surgery in the form of pelvic osteotomy. Comparison of preoperative and postoperative range of motion of the hip joint between groups detected capsular insufficiency, increased ligamentous laxity and muscular hypotonia in patients with Down syndrome. Comparison of pelvic radiographs demonstrated significant improvement concerning measured angles in both groups. Preoperative values with respect to AC angle and CE angle were demonstrated to be lower in the hip dysplasia group (p < 0.01); whereas values for ACM angle were comparable between groups. Hypermobility and secondary dislocation of the hip joint is a common problem in patients with Down syndrome, which often requires surgical intervention at an early stage. According to our data and clinical results we suggest a complete redirectional acetabular osteotomy in combination with capsular plication for treatment of this challenging condition. Georg Thieme Verlag KG Stuttgart · New York.
Sedrakyan, Art; Normand, Sharon-Lise T; Dabic, Stefan; Jacobs, Samantha; Graves, Stephen; Marinac-Dabic, Danica
2011-11-29
To determine comparative safety and effectiveness of combinations of bearing surfaces of hip implants. Systematic review of clinical trials, observational studies, and registries. Medline, Embase, Cochrane Controlled Trials Register, reference lists of articles, annual reports of major registries, summaries of safety and effectiveness for pre-market application and mandated post-market studies at the United States Food and Drug Administration. Criteria for inclusion were comparative studies in adults reporting information for various combinations of bearings (such as metal on metal and ceramic on ceramic). Data search, abstraction, and analyses were independently performed and confirmed by at least two authors. Qualitative data syntheses were performed. There were 3139 patients and 3404 hips enrolled in 18 comparative studies and over 830 000 operations in national registries. The mean age range in the trials was 42-71, and 26-88% were women. Disease specific functional outcomes and general quality of life scores were no different or they favoured patients receiving metal on polyethylene rather than metal on metal in the trials. While one clinical study reported fewer dislocations associated with metal on metal implants, in the three largest national registries there was evidence of higher rates of implant revision associated with metal on metal implants compared with metal on polyethylene. One trial reported fewer revisions with ceramic on ceramic compared with metal on polyethylene implants, but data from national registries did not support this finding. There is limited evidence regarding comparative effectiveness of various hip implant bearings. Results do not indicate any advantage for metal on metal or ceramic on ceramic implants compared with traditional metal on polyethylene or ceramic on polyethylene bearings.
[Orthopedic management of spina bifida].
Biedermann, R
2014-07-01
Spina bifida is associated with congenital deformities, such as kyphosis, spinal malformations, teratological hip dislocations, clubfeet, vertical talus and also with acquired deformities due to muscle imbalance and impaired biomechanics. The degree of the acquired deformities and the mobility of the patient depend on the level of the spinal lesion. Neurological symptoms are mostly asymmetric and there is an inconsistent correlation between the anatomical level of the lesion and muscle function. Deficits of sensation are usually one to two levels lower than the motor level. An exact neurological diagnosis should not be made before the second or third year of life and an early prognosis about walking ability should be avoided. The level L3 and therefore function of the quadriceps is a functional milestone after which modified independent ambulation with the use of ankle foot orthoses (AFO) and crutches is possible. The basic principle is to support verticalization and gait even when loss of ambulation is later expected. It is also important to support and maintain sitting ability for high lesions, if necessary with correction of the spinal deformity. Findings in gait analysis have shifted the focus of treatment from radiological criteria to functional improvement, thus maintenance of the flexibility of the hip is the main goal of hip surgery. Reduction of the hip often leads to stiffness and has a high redislocation rate. Clubfoot deformities should be treated early and foot arthrodesis and stiffness have to be avoided. Another focus is the prevention of joint contracture by early prophylactic treatment. The purpose of management is to maximize the functional potential of the child. Subjective well-being, absence of pain, mobility and socialization are the main goals. This does not necessarily imply ambulation; nevertheless, verticalization and associated orthotic management is one major objective of the orthopedic management of spina bifida.
Cadossi, Matteo; Garcia, Flávio Luís; Sambri, Andrea; Andreoli, Isabella; Dallari, Dante; Pignatti, Giovanni
2017-01-01
Inadequate acetabular bone stock is a major issue in total hip arthroplasty, and several treatment options are available. Stemmed cups have been used in this scenario with variable results. A novel modular polyaxial uncemented iliac screw cup (HERM-BS-Sansone cup-Citieffe s.r.l., Calderara di Reno, Bologna, Italy) has been recently introduced to overcome the drawbacks of stemmed cups. In this retrospective study, we report the results of this cup in patients with large acetabular bone defects at 2- to 7-year follow-up. We evaluated a consecutive series of 121 hips (118 revisions and 3 complex primary arthroplasties) treated with this novel cup at a mean follow-up of 46 months. Kaplan-Meier survival analysis was performed with implant revision for any reason as a primary end point. Further survival analysis was performed excluding septic failures. Clinical outcome was assessed with the Harris Hip Score. There had been 7 reoperations: 1 for aseptic loosening, 5 for deep infection, and 1 for recurrent dislocation. In 5 cases, the cup was removed; estimated survival rate at 5-year follow-up with implant removal for any reason was 95.6% (95% confidence interval = 91-99), and 98.3% (95% CI = 96-100) excluding those failed for infection. Mean Harris Hip Score at latest follow-up was 77 points (range, 44-95; standard deviation = 11.9). The present findings show the short-term efficacy of the iliac screw cup with respect to implant survival. A longer follow-up and a larger number of patients are necessary to confirm the encouraging preliminary results. Copyright © 2016 Elsevier Inc. All rights reserved.
Fukuda, Thiago Yukio; Rossetto, Flavio Marcondes; Magalhães, Eduardo; Bryk, Flavio Fernandes; Lucareli, Paulo Roberto Garcia; de Almeida Aparecida Carvalho, Nilza
2010-11-01
Randomized clinical trial. To investigate the influence of strengthening the hip abductor and lateral rotator musculature on pain and function of females with patellofemoral pain syndrome (PFPS). Hip muscle weakness in women athletes has been the focus of many recent studies and is suggested as an important impairment to address in the conservative treatment of women with PFPS. However, it is still not well established if strengthening these muscles is associated with clinical improvement in pain and function in sedentary females with PFPS. Seventy females (average±SD age, 25±07 years), with a diagnosis of unilateral PFPS, were distributed randomly into 3 groups: 22 females in the knee exercise group, who received a conventional treatment that emphasized stretching and strengthening of the knee musculature; 23 females in the knee and hip exercise group, who performed exercises to strengthen the hip abductors and external rotators in addition to the same exercises performed by those in the knee exercise group; and of the 25 females who did not receive any treatment. The females of the nontreatment group (control) were instructed to maintain their normal daily activities. An 11-point numerical pain rating scale (NPRS) was used to assess pain during stair ascent and descent. The lower extremity functional scale (LEFS) and the anterior knee pain scale (AKPS) were used to assess function. The single-limb single hop test was also used as a functional outcome to measure preintervention and 4-week postintervention function. The 3 groups were homogeneous prior to treatment in respect to demographic, pain, and functional scales data. Both the knee exercise and the knee and hip exercise groups showed significant improvement in the LEFS, the AKPS, and the NPRS, when compared to the control group (P<.05 and P<.001, respectively). But, when we considered minimal clinically important differences, only the knee and hip exercise group demonstrated mean improvements in AKPS and pain scores that were large enough to be clinically meaningful. For the single-limb single hop test, both groups receiving an intervention showed greater improvement than the control group, but there was no difference between the 2 interventions (P>.05). Rehabilitation programs focusing on knee strengthening exercises and knee strengthening exercises supplemented by hip strengthening exercises were both effective in improving function and reducing pain in sedentary women with PFPS. Improvements of pain and function were greater for the group that performed the hip strengthening exercises, but the difference was significant only for pain rating while descending stairs. Therapy, level 1b-.
Hirotani, Hayato
2009-03-01
In addition to articles written by Prof. Dr. M. Matsuoka previously reported in Part 2, books written by him are presented as Part 3 of the articles regarding his academic achievements. He published four text books, including the first textbook of orthopaedic surgery in Japan that was written by a Japanese doctor and a monograph on the x-ray atlas of congenital dislocation of the hip that was written in German and published in Germany. He was also invited to submit articles to three books as co-author. Furthermore, his five educational lectures given to the public were published in two books.
Femoroacetabular Impingement Surgery Is on the Rise-But What Is the Next Step?
Reiman, Michael P; Thorborg, Kristian; Hölmich, Per
2016-06-01
Surgery for femoroacetabular impingement (FAI) has been advocated for correction of cam and pincer hip joint morphology. Surgery for FAI was first pioneered by Myers et al, who surgically treated FAI by open dislocation. Arthroscopy was then introduced in 2005 by Sampson. Arthroscopy has continued to develop since then, with the intent of providing pain relief and improving function in patients with FAI. This Viewpoint discusses the escalating popularity of FAI surgery, the widespread acceptance of this relatively new surgical procedure, and next steps for determination of who benefits from this treatment. J Orthop Sports Phys Ther 2016;46(6):406-408. doi:10.2519/jospt.2016.0605.
Creep of quartz by dislocation and grain boundary processes
NASA Astrophysics Data System (ADS)
Fukuda, J. I.; Holyoke, C. W., III; Kronenberg, A. K.
2015-12-01
Wet polycrystalline quartz aggregates deformed at temperatures T of 600°-900°C and strain rates of 10-4-10-6 s-1 at a confining pressure Pc of 1.5 GPa exhibit plasticity at low T, governed by dislocation glide and limited recovery, and grain size-sensitive creep at high T, governed by diffusion and sliding at grain boundaries. Quartz aggregates were HIP-synthesized, subjecting natural milky quartz powder to T=900°C and Pc=1.5 GPa, and grain sizes (2 to 25 mm) were varied by annealing at these conditions for up to 10 days. Infrared absorption spectra exhibit a broad OH band at 3400 cm-1 due to molecular water inclusions with a calculated OH content (~4000 ppm, H/106Si) that is unchanged by deformation. Rate-stepping experiments reveal different stress-strain rate functions at different temperatures and grain sizes, which correspond to differing stress-temperature sensitivities. At 600-700°C and grain sizes of 5-10 mm, flow law parameters compare favorably with those for basal plasticity and dislocation creep of wet quartzites (effective stress exponents n of 3 to 6 and activation enthalpy H* ~150 kJ/mol). Deformed samples show undulatory extinction, limited recrystallization, and c-axis maxima parallel to the shortening direction. Similarly fine-grained samples deformed at 800°-900°C exhibit flow parameters n=1.3-2.0 and H*=135-200 kJ/mol corresponding to grain size-sensitive Newtonian creep. Deformed samples show some undulatory extinction and grain sizes change by recrystallization; however, grain boundary deformation processes are indicated by the low value of n. Our experimental results for grain size-sensitive creep can be compared with models of grain boundary diffusion and grain boundary sliding using measured rates of silicon grain boundary diffusion. While many quartz mylonites show microstructural and textural evidence for dislocation creep, results for grain size-sensitive creep may apply to very fine-grained (<10 mm) quartz mylonites.
Ehlers–Danlos Syndrome—Hypermobility Type: A Much Neglected Multisystemic Disorder
Gazit, Yael; Jacob, Giris; Grahame, Rodney
2016-01-01
Ehlers–Danlos syndrome (EDS)—hypermobility type (HT) is considered to be the most common subtype of EDS and the least severe one; EDS-HT is considered to be identical to the joint hypermobility syndrome and manifests with musculoskeletal complaints, joint instability, and soft tissue overuse injury. Musculoskeletal complaints manifest with joint pain of non-inflammatory origin and/or spinal pain. Joint instability leads to dislocation or subluxation and involves peripheral joints as well as central joints, including the temporomandibular joints, sacroiliac joints, and hip joints. Soft tissue overuse injury may lead to tendonitis and bursitis without joint inflammation in most cases. Ehlers–Danlos syndrome-HT carries a high potential for disability due to recurrent dislocations and subluxations and chronic pain. Throughout the years, extra-articular manifestations have been described, including cardiovascular, autonomic nervous system, gastrointestinal, hematologic, ocular, gynecologic, neurologic, and psychiatric manifestations, emphasizing the multisystemic nature of EDS-HT. Unfortunately, EDS-HT is under-recognized and inadequately managed, leading to neglect of these patients, which may lead to severe disability that almost certainly could have been avoided. In this review article we will describe the known manifestations of the extra-articular systems. PMID:27824552
Stabilization of a three-dimensional limit cycle walking model through step-to-step ankle control.
Kim, Myunghee; Collins, Steven H
2013-06-01
Unilateral, below-knee amputation is associated with an increased risk of falls, which may be partially related to a loss of active ankle control. If ankle control can contribute significantly to maintaining balance, even in the presence of active foot placement, this might provide an opportunity to improve balance using robotic ankle-foot prostheses. We investigated ankle- and hip-based walking stabilization methods in a three-dimensional model of human gait that included ankle plantarflexion, ankle inversion-eversion, hip flexion-extension, and hip ad/abduction. We generated discrete feedback control laws (linear quadratic regulators) that altered nominal actuation parameters once per step. We used ankle push-off, lateral ankle stiffness and damping, fore-aft foot placement, lateral foot placement, or all of these as control inputs. We modeled environmental disturbances as random, bounded, unexpected changes in floor height, and defined balance performance as the maximum allowable disturbance value for which the model walked 500 steps without falling. Nominal walking motions were unstable, but were stabilized by all of the step-to-step control laws we tested. Surprisingly, step-by-step modulation of ankle push-off alone led to better balance performance (3.2% leg length) than lateral foot placement (1.2% leg length) for these control laws. These results suggest that appropriate control of robotic ankle-foot prosthesis push-off could make balancing during walking easier for individuals with amputation.
Kim, Juseung; Park, Minchul
2016-09-01
[Purpose] This study compared abdominal and hip extensor muscle activity during a bridge exercise with various knee joint angles. [Subjects and Methods] Twenty-two healthy male subjects performed a bridge exercise in which the knee joint angle was altered. While subjects performed the bridge exercise, external oblique, internal oblique, gluteus maximus, and semitendinosus muscle activity was measured using electromyography. [Results] The bilateral external and internal oblique muscle activity was significantly higher at 0° knee flexion compared to 120°, 90°, and 60°. The bilateral gluteus maximus muscle activity was significantly different at 0° of knee flexion compared to 120°, 90°, and 60°. The ipsilateral semitendinosus muscle activity was significantly increased at 90° and 60° of knee flexion compared to 120°, and significantly decreased at 0° knee flexion compared with 120°, 90°, and 60°. The contralateral semitendinosus muscle activity was significantly higher at 60° of knee flexion than at 120°, and significantly higher at 0° of knee flexion than at 120°, 90°, and 60°. [Conclusion] Bridge exercises performed with knee flexion less than 90° may be used to train the ipsilateral semitendinosus. Furthermore, bridge exercise performed with one leg may be used to train abdominal and hip extensor muscles.
Kumar L K, Surej; Manuel, Suvy; Kurien, Nikhil M; Khalam, Sherin A; P Menon, Varun
2015-01-01
In a condylar fracture whether to intervene or to go for conservative management still remains a dilemma. Studies and hypothesis suggests that it's medially dislocated condylar fracture segment that is more likely to ankylose, moreover no consensus have been put forth as to whether to remove the medially displaced fracture segment. The current article describes a case of unilateral temporomandibular joint (TMJ) ankylosis, which resulted as a sequlae from conservative management of a bilateral condylar fracture of which, the ankylosed side had a sagittal fracture of condyle. In our case the post trauma CT shows the lateral segment abutting with the arch and that the area has become ankylotic in a span of 2 years. Here we report a case of posttraumatic unilateral TMJ ankylosis resulting from closed reduction of a bilateral condylar fracture with interesting radiological findings. We have tried to discuss a rather interesting radiological picture of posttraumatic TMJ ankylosis which resulted as a sequlae from conservative management of a bilateral condylar fracture. The dilemma for a clinician as to whether to intervene in a condylar fracture or to go for conservative management still remains at large. As in this case the medial fracture segment was intact and the lateral segment was resulting in ankylosis. Copyright © 2015. Published by Elsevier Ltd.
Activation of the hip adductor muscles varies during a simulated weight-bearing task.
Hides, Julie A; Beall, Paula; Franettovich Smith, Melinda M; Stanton, Warren; Miokovic, Tanja; Richardson, Carolyn
2016-01-01
To investigate the pattern of muscle activation of the individual hip adductor muscles using a standardised simulated unilateral weight-bearing task. A repeated measures design. Laboratory. 20 healthy individuals (11 females, 9 males) participated in the study. Age ranged from 20 to 25 years. Surface electromyography recordings from adductor magnus and adductor longus muscles were taken at levels representing 10-50% of body weight during a simulated weight-bearing task. Electromyography (EMG) data were normalised to maximal voluntary isometric contraction. The adductor magnus was recruited at significantly higher levels than the adductor longus muscle during a simulated weight-bearing task performed across 10-50% of body weight (p < 0.01). Adductor magnus and adductor longus muscles are recruited to different extents during a simulated weight-bearing task. This information should be considered when selecting exercises for management and prevention of groin strains. Closed chain exercises with weight-bearing through the lower limb are more likely to recruit the adductor magnus muscle over the adductor longus muscle. Copyright © 2015 Elsevier Ltd. All rights reserved.
Karagiannis, A; Papakitsou, E; Dretakis, K; Galanos, A; Megas, P; Lambiris, E; Lyritis, G P
2006-02-01
Increased mortality after a hip fracture has been associated with age, sex, and comorbidity. In order to estimate the long-term mortality with reference to hip fracture type, we followed 499 patients older than 60 years who had been treated surgically for a unilateral hip fracture for 10 years. At admission, patients with femoral neck fractures (n = 172) were 2 years younger than intertrochanteric patients (77.6 +/- 7.7 [SD] vs. 79.9 +/- 7.4 [SD], P = 0.001) and had a greater prevalence of heart failure (57% vs. 40.3%, P = 0.03). Similar mortality rates were observed at 1 year in both types of fracture (17.9% vs. 11.3%, log rank test P = 0.112). Mortality rates were significantly higher for intertrochanteric fractures at 5 years (48.8% vs. 34.7%, P = 0.01) and 10 years (76% vs. 58%, P = 0.001). Patients 60-69 years old with intertrochanteric fractures had significantly higher 10-year mortality than patients of similar age with femoral neck fractures (P = 0.008), while there was no difference between the groups aged 70-79 (P > 0.3) and 80-89 (P = 0.07). Women were less likely to die in 5 years (relative risk [RR] = 0.57, 95% confidence interval [CI] 0.41-0.79, P = 0.0007) and 10 years (RR = 0.65, 95% CI 0.49-0.85, P = 0.002). Age, sex, the type of fracture, and the presence of heart failure were independent predictors of 10-year mortality (Cox regression model P < 0.0001). The intertrochanteric type was independently associated with 1.37 (95% CI 1.03-1.83) times higher probability of death at 10 years (P = 0.002). In conclusion, the type of fracture is an independent predictor of long-term mortality in patients with hip fractures, and the intertrochanteric type yields worse prognosis.
Nikamp, Corien D M; van der Palen, Job; Hermens, Hermie J; Rietman, Johan S; Buurke, Jaap H
2018-06-01
Compensatory pelvis, hip- and knee movements are reported after stroke to overcome insufficient foot-clearance. Ankle-foot orthoses (AFOs) are often used to improve foot-clearance, but the optimal timing of AFO-provision post-stroke is unknown. Early AFO-provision to prevent foot-drop might decrease the development of compensatory movements, but it is unknown whether timing of AFO-provision affects post-stroke kinematics. 1) To compare the effect of AFO-provision at two different points in time (early versus delayed) on frontal pelvis and hip, and sagittal hip and knee kinematics in patients with sub-acute stroke. Effects were assessed after 26 weeks; 2) To study whether possible changes in kinematics or walking speed during the 26-weeks follow-up period differed between both groups. An explorative randomized controlled trial was performed, including unilateral hemiparetic patients maximal six weeks post-stroke with indication for AFO-use. Subjects were randomly assigned to AFO-provision early (at inclusion) or delayed (eight weeks later). 3D gait-analysis with and without AFO was performed in randomized order. Measurements were performed in study-week 1, 9, 17 and 26. Twenty-six subjects (15 early, 11 delayed) were analyzed. After 26 weeks, no differences in kinematics were found between both groups for any of the joint angles, both for the without and with AFO-condition. Changes in kinematics during the 26-weeks follow-up period did not differ between both groups for any of the joint angles during walking without AFO. Significant differences in changes in walking speed during the 26-weeks follow-up were found (p = 0.034), corresponding to the first eight weeks after AFO-provision. Results indicate that early or delayed AFO-use post-stroke does not influence pelvis, hip and knee movements after 26 weeks, despite that AFO-use properly corrected drop-foot. AFOs should be provided to improve drop-foot post-stroke, but not with the intention to influence development of compensatory patterns around pelvis and hip. Copyright © 2018 Elsevier B.V. All rights reserved.
Irie, Tohru; Takahashi, Daisuke; Asano, Tsuyoshi; Arai, Ryuta; Terkawi, Muhammad Alaa; Ito, Yoichi M; Iwasaki, Norimasa
2018-07-01
The definitive treatment of borderline-to-mild dysplasia remains controversial. A more comprehensive understanding of the etiology of osteoarthritis (OA) and clarification of any possible association between borderline-to-mild dysplasia and the pathogenesis of OA are essential. (1) Does the distribution of acetabular subchondral bone density increase according to dysplasia severity? (2) Is there an association between borderline-to-mild dysplasia and OA pathogenesis? We evaluated bilateral hips of patients with developmental dysplasia of the hip who underwent eccentric rotational acetabular osteotomy (ERAO) for inclusion in the dysplasia group and contralateral hips of patients with unilateral idiopathic osteonecrosis of the femoral head (ONFH) who underwent curved intertrochanteric varus osteotomy (CVO) for the control group. ERAO was performed in 46 patients and CVO was performed in 32 patients between January 2013 and August 2016 at our institution. All patients underwent bilateral hip CT. The study included 55 hips categorized according to dysplasia severity: (1) borderline-mild, 19 hips (15° ≤ lateral center-edge angle [LCEA] < 25°); (2) moderate, 20 hips (5° ≤ LCEA < 15°); (3) severe, 16 hips (LCEA < 5°); and (4) control, 15 hips. Thirty-seven dysplastic hips (age < 15 or > 50 years old, prior hip surgery, subluxation, aspherical femoral head, cam deformity, and radiographic OA) and 17 control hips (age < 15 or > 50 years old, bilateral ONFH, LCEA < 25° or ≥ 35°, cam deformity, and radiographic OA) were excluded. CT-osteoabsorptiometry (OAM) predicts physiologic biomechanical conditions in joints by evaluating subchondral bone density. We evaluated the distribution of subchondral bone densities in the acetabulum with CT-OAM, dividing the stress distribution map into six segments: anteromedial, anterolateral, centromedial, centrolateral, posteromedial, and posterolateral. We calculated the percentage of high-density area, which was defined as the upper 30% of Hounsfield units values in each region and compared least square means difference estimated by the random intercept model among the four groups. In all regions, the percentage of high-density area did not differ between the borderline-mild group and the control (eg, anterolateral, 16.2 ± 5.6 [95% CI, 13.4 to 18.9] versus 15.5 ± 5.7 [95% CI, 12.4 to 18.5, p = 0.984]; centrolateral, 39.1 ± 5.7 [95% CI, 36.4 to 41.8] versus 39.5 ± 4.7 [95% CI, 36.6 to 42.5, p = 0.995]; posterolateral, 10.9 ± 5.2 [95% CI, 8.0 to 13.8] versus 15.1 ± 6.8 [95% CI, 11.7 to 18.5, p = 0.389]). In the anterolateral region, a smaller percentage of high-density area was observed in the borderline-mild group than in both the moderate group (16.2 ± 5.6 [95% CI, 13.4-18.9] versus 28.2 ± 5.1 [95% CI, 25.5-30.9], p < 0.001) and the severe group (16.2 ± 5.6 [95% CI, 13.4-18.9] versus 22.2 ± 6.8 [95% CI, 19.2-25.2, p = 0.026). Our results suggest that the cumulative hip stress distribution in borderline-to-mild dysplasia was not concentrated on the lateral side of the acetabulum, unlike severe dysplasia. Based on the stress distribution pattern, our results may suggest that there is no association between borderline-to-mild dysplasia and the pathogenesis of OA. Further studies are needed to evaluate the association between borderline-to-mild dysplasia and instability of the hip.
Terjesen, Terje; Wiig, Ola; Svenningsen, Svein
2012-09-01
In the Norwegian prospective study on Legg-Calvé-Perthes disease (LCPD), we found varus femoral osteotomy gave better femoral head sphericity at a mean of 5 years postoperative than physiotherapy in children older than 6.0 years at diagnosis with femoral head necrosis of more than 50%. That study did not include separate analyses for hips with 100% necrosis and those with a percentage of necrosis between 50% and 100%. We asked whether (1) femoral osteotomy improves femoral head sphericity at followup in all patients with more than 50% femoral head necrosis or in selected groups only and (2) there is a critical age between 6.0 and 10.0 years over which femoral osteotomy does not improve the prognosis. We treated 70 patients with unilateral LCPD, age at diagnosis of more than 6.0 years, and femoral head necrosis of more than 50% with varus femoral osteotomy between 1996 and 2000. We classified necrosis using the Catterall classification. We established a control group of 51 similar children who received physiotherapy. At the 5-year followup visit, the hips were graded according to femoral head shape: spherical, ovoid, or flat. At 5-year followup, there was no difference between the treatment groups in radiographic outcome in Catterall Group 3 hips. In Catterall Group 4 hips, femoral head sphericity was better in the osteotomy group, with flat femoral heads in 14% compared to 75% after physiotherapy. The same trend toward better head sphericity occurred when the lateral pillar classification was used. In children aged 6.0 to 10.0 years, in whom the whole femoral head is affected, femoral head sphericity 5 years after femoral osteotomy was better than that after physiotherapy.
Peterson, Margaret G.E.; Cornell, Charles N.; MacKenzie, C. Ronald; Robbins, Laura; Horton, Roberta; Ganz, Sandy B.; Ruchlin, Hirsch S.; Russo, Pamela Williams; Paget, Stephen A.; Charlson, Mary E.
2006-01-01
We conducted a randomized controlled trial to assess the efficacy and safety of a multiple-component intervention designed to improve functional recovery after hip fracture. One hundred seventy-six patients who underwent surgery for a primary unilateral hip fracture were assigned randomly to receive usual care (control arm, n = 86) or a brief motivational videotape, supportive peer counseling, and high-intensity muscle-strength training (intervention arm, n = 90). Between-group differences on the physical functioning, role-physical, and social functioning domains of the SF-36 were assessed postoperatively at 6 months. At the end of the trial, 32 intervention and 27 control patients (34%) completed the 6-month outcome assessment. Although patient compliance with all three components of the intervention was uneven, over 90% of intervention patients were exposed to the motivational videotape. Intervention patients experienced a significant (P = 0.03) improvement in the role-physical domain (mean change, −11 ± 33) compared to control patients (mean change, −37 ± 41). Change in general health (P = 0.2) and mental health (P = 0.1) domain scores was also directionally consistent with the study hypothesis. Although our findings are consistent with previous reports of comprehensive rehabilitation efforts for hip fracture patients, the trial was undermined by high attrition and the possibility of self-selection bias at 6-month follow-up. We discuss the methodological challenges and lessons learned in conducting a randomized controlled trial that sought to implement and assess the impact of a complex intervention in a population that proved difficult to follow up once they had returned to the community. PMID:18751772
Plenge, U; Nortje, M B; Marais, L C; Jordaan, J D; Parker, R; van der Westhuizen, N; van der Merwe, J F; Marais, J; September, W V; Davies, G L; Pretorius, T; Solomon, C; Ryan, P; Torborg, A M; Farina, Z; Smit, R; Cairns, C; Shanahan, H; Sombili, S; Mazibuko, A; Hobbs, H R; Porrill, O S; Timothy, N E; Siebritz, R E; van der Westhuizen, C; Troskie, A J; Blake, C A; Gray, L A; Munting, T W; Steinhaus, H K S; Rowe, P; van der Walt, J G; Isaacs Noordien, R; Theron, A; Biccard, B M
2018-05-09
A structured approach to perioperative patient management based on an enhanced recovery pathway protocol facilitates early recovery and reduces morbidity in high income countries. However, in low- and middle-income countries (LMICs), the feasibility of implementing enhanced recovery pathways and its influence on patient outcomes is scarcely investigated. To inform similar practice in LMICs for total hip and knee arthroplasty, it is necessary to identify potential factors for inclusion in such a programme, appropriate for LMICs. Applying a Delphi method, 33 stakeholders (13 arthroplasty surgeons, 12 anaesthetists and 8 physiotherapists) from 10 state hospitals representing 4 South African provinces identified and prioritised i) risk factors associated with poor outcomes, ii) perioperative interventions to improve outcomes and iii) patient and clinical outcomes necessary to benchmark practice for patients scheduled for primary elective unilateral total hip and knee arthroplasty. Thirty of the thirty-three stakeholders completed the 3 months Delphi study. The first round yielded i) 36 suggestions to preoperative risk factors, ii) 14 (preoperative), 18 (intraoperative) and 23 (postoperative) suggestions to best practices for perioperative interventions to improve outcomes and iii) 25 suggestions to important postsurgical outcomes. These items were prioritised by the group in the consecutive rounds and consensus was reached for the top ten priorities for each category. The consensus derived risk factors, perioperative interventions and important outcomes will inform the development of a structured, perioperative multidisciplinary enhanced patient care protocol for total hip and knee arthroplasty. It is anticipated that this study will provide the construct necessary for developing pragmatic enhanced care pathways aimed at improving patient outcomes after arthroplasty in LMICs.
Orishimo, Karl F; McHugh, Malachy P
2015-03-01
The purposes of this study were to document relative activation intensities of the hamstrings and gluteus maximus during 4 eccentric hamstring strengthening exercises and to assess the effects of a short-term strengthening program comprised of these exercises on knee flexor strength and the length-tension relationship. Twelve healthy subjects participated in this study. Electromyographic (EMG) activities from the biceps femoris, semitendinosus, and gluteus maximus were recorded as subjects performed (a) standing hip extension with elastic resistance, (b) trunk flexion in single limb stance (diver), (c) standing split (glider), and (d) supine sliding bridge (slider). Baseline isometric knee flexor strength was measured at 90, 70, 50, and 30° of flexion at the knee with the subject seated and the hip flexed to 50° from horizontal. After completing the 4-week training program, strength tests were repeated. Repeated-measures analysis of variance were used to compare EMG activity between muscles and to assess angle-specific strength improvements. Hamstring activity exceeded gluteus maximus activity for resisted hip extension, glider, and slider exercises (p < 0.001) but not for the diver (p = 0.087). Hamstring activation was greatest during the slider and resisted hip extension and lowest during the glider and the diver. Knee flexor strength improved by 9.0% (p = 0.005) but was not angle specific (training by angle p = 0.874). The short-term home training program effectively targeted the hamstrings and resulted in strength gains that were similar at short and long muscle lengths. These data demonstrate that hamstring strength can be improved using eccentrically biased unilateral exercises without the use of weights or other equipments.
Nakanowatari, Tatsuya; Suzukamo, Yoshimi; Suga, Toshimitsu; Okii, Akira; Fujii, Genji; Izumi, Shin-Ichi
2013-01-01
The associations between leg length discrepancy (LLD) and patient-perceived inequality and functional outcomes after total hip arthroplasty (THA) are unclear in the literature. The aim of this study was to determine the types of LLD after THA and to identify the best predictor of patient-perceived LLD and functional outcome in the short term after THA. We subdivided LLD into true and apparent types and prospectively studied 53 consecutive patients undergoing unilateral primary THA to determine whether there is an association between the type of LLD and functional outcome 2 months after the operation. Apparent LLD was measured by the block test and true LLD was measured by hip radiography. We classified the patients into 4 groups: true, apparent, mixed, and no-LLD groups. The questionnaire included a visual analog scale of pain, the Western Ontario and McMaster Universities Osteoarthritis Index, and patient-perceived inequality. Physical performance was measured using walking speed and the Timed Up and Go test. The apparent and mixed LLD groups had a higher prevalence of patient-perceived inequality than the true and no-LLD groups. The results of physical performance showed that the walking speed of the mixed LLD group and the results of the Timed Up and Go Test of the apparent LLD group were significantly slower than those of the true LLD group. We suggested that the true LLD group may have a weak relationship with functional outcome after THA while the apparent LLD resulting from pelvic obliquity due to hip contracture or scoliosis is correlated with the short-term functional outcome after THA. Apparent LLD can be a better predictor of patient-perceived inequality and physical performance than true LLD.
Zufferey, Paul J; Lanoiselée, Julien; Chapelle, Céline; Borisov, Dmitry B; Bien, Jean-Yves; Lambert, Pierre; Philippot, Rémi; Molliex, Serge; Delavenne, Xavier
2017-09-01
Preoperative administration of the antifibrinolytic agent tranexamic acid reduces bleeding in patients undergoing hip arthroplasty. Increased fibrinolytic activity is maintained throughout the first day postoperation. The objective of the study was to determine whether additional perioperative administration of tranexamic acid would further reduce blood loss. This prospective, double-blind, parallel-arm, randomized, superiority study was conducted in 168 patients undergoing unilateral primary hip arthroplasty. Patients received a preoperative intravenous bolus of 1 g of tranexamic acid followed by a continuous infusion of either tranexamic acid 1 g (bolus-plus-infusion group) or placebo (bolus group) for 8 h. The primary outcome was calculated perioperative blood loss up to day 5. Erythrocyte transfusion was implemented according to a restrictive transfusion trigger strategy. The mean perioperative blood loss was 919 ± 338 ml in the bolus-plus-infusion group (84 patients analyzed) and 888 ± 366 ml in the bolus group (83 patients analyzed); mean difference, 30 ml (95% CI, -77 to 137; P = 0.58). Within 6 weeks postsurgery, three patients in each group (3.6%) underwent erythrocyte transfusion and two patients in the bolus group experienced distal deep-vein thrombosis. A meta-analysis combining data from this study with those of five other trials showed no incremental efficacy of additional perioperative administration of tranexamic acid. A preoperative bolus of tranexamic acid, associated with a restrictive transfusion trigger strategy, resulted in low erythrocyte transfusion rates in patients undergoing hip arthroplasty. Supplementary perioperative administration of tranexamic acid did not achieve any further reduction in blood loss.
Poulsen, E; Hartvigsen, J; Christensen, H W; Roos, E M; Vach, W; Overgaard, S
2013-10-01
To investigate the effectiveness of a patient education (PE) program with or without the added effect of manual therapy (MT) compared to a minimal control intervention (MCI). In a single-center university hospital setting, a total of 118 patients with clinical and radiographic unilateral hip osteoarthritis (OA) from primary care were randomized into one of three groups: PE, PE plus MT or MCI. The PE was taught by a physiotherapist involving five sessions. The MT was delivered by a chiropractor involving 12 sessions and the MCI included a home stretching program. Primary outcome was self-reported pain severity on an 11-box numeric rating scale (NRS) immediately following a 6-week intervention period. Patients were followed for 1 year. Primary analysis included 111 patients (94%). In the combined group (PE + MT), a clinically relevant reduction in pain severity compared to the MCI of 1.90 points (95% confidence interval (CI) 0.9-2.9) was achieved. Effect size (Cohen's d) for the PE + MT minus the MCI was 0.92 (95% CI 0.41-1.42). Number needed to treat for PE + MT was 3 (95% CI 2-7). No difference was found between the PE and MCI groups, with mean difference 0.0 (95% CI -1.0 to 1.0). At 12 months, not including patients receiving hip surgery the statistically significant difference favoring PE + MT was maintained. For primary care patients with OA of the hip, a combined intervention of MT and PE was more effective than a MCI. PE alone was not superior to the MCI. clinicaltrials.govNCT01039337. Copyright © 2013 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Rozkydal, Z; Janíček, P; Otiepka, P
2010-01-01
The aim of this retrospective study was to assess the results of varus osteotomy of the proximal femur in adults with coxa valga after developmental dysplasia of the hip (DDH) and to evaluate the efficacy of this method. Thirty hips in 28 patients treated by proximal femoral varus osteotomy in the period from 1983 to 1990 were evaluated. The indication for surgery involved coxa valga (145°-168°) with grade I- III of osteoarthritis and mild acetabular dysplasia. The patient group comprised twenty six women and two men with an average age of 28 years (18 to 42) at the time of surgery. The mean follow-up was 22 years (19 to 26). The preoperative radiographic examination included an AP view of the pelvis, AP views of the hip in neutral and in frog-leg position and AP views of the hip in 30° of abduction and neutral rotation. Varus osteotomy was indicated when the best position of the hip joint was achieved in abduction. The procedure was performed according to M. Müller. Hip assessment was based on the grade of osteoarthritis, CCD angle, Wiberg angle and AHI index. The results were statistically evaluated using the life table analysis of clinical survivorship of osteotomy and the Kaplan- Meier curve. Clinical failure was defined as conversion of osteotomy to total hip replacement (THR). At the latest follow-up of 22 years on the average, 18 patients (19 hips) still had osteotomy and 10 patients (11 hips) had undergone conversion to THR. The life table analysis showed the cumulative proportion of osteotomy with a clinical survivorship of 0.97 at 5 years, 0.75 at 10 and 15 years, and 0.68 at 20 and 25 years after surgery. The cumulative rate of clinical survivorship of osteotomy, as shown by the Kaplan-Meier curve, was 0.89 at 10 years, 0.75 at 20 years and 0.67 at 25 years after surgery. Nineteen patients were satisfied with the osteotomy outcome. The median of Harris hip scores in the patients with osteotomy was 48 points before surgery and 78 points at the latest follow-up. Conversion to THR in 10 patients (11 hips) was done at an average of 12 years after osteotomy. The median values before surgery and at the latest follow-up were: CCD angle, 158° and 118°; Wiberg angle, 13° and 20°; and AHI index, 56 % and 79 %, respectively. The prerequisite for a good result of proximal femoral varus osteotomy is the correct indication, i.e., younger age (18 to 30 years), a lower grade of osteoarthritis, mild dysplasia and a spherical shape of the femoral head. A disadvantage of the procedure is a shortening of the limb. The best indication for femoral varus osteotomy is unilateral coxa valga with a longer leg. This study shows favourable long-term results after isolated proximal femoral varus osteotomy in young adults with developmental dysplasia of the hip. A good function had been preserved in 18 of 28 DDH patients for an average of 22 years.
Bailey, Christine A; Brooke-Wavell, Katherine
2010-04-01
Exercise can increase bone strength, but to be effective in reducing fracture risk, exercise must be feasible enough to be adopted into daily life and influence potentially vulnerable skeletal sites such as the superolateral cortex of the femoral neck, where thinning is associated with increased fracture risk. Brief, high-impact exercise increases femoral neck bone density but the optimal frequency of such exercise and the location of bone accrual is unknown. This study thus examined (1) the effectiveness of different weekly frequencies of exercise on femoral neck BMD and (2) whether BMD change differed between hip sites using a high-impact, unilateral intervention. Healthy premenopausal women were randomly assigned to exercise 0, 2, 4, or 7 days/week for 6 months. The exercise intervention incorporated 50 multidirectional hops on one randomly selected leg. BMD was measured by DXA at baseline and after 6 months of exercise. Changes in the exercise leg were compared between groups using ANCOVA, with change in the control leg and baseline BMD as covariates. RM-MANOVA was conducted to determine whether bone changes from exercise differed between hip sites. 61 women (age 33.6+/-11.1 years) completed the intervention. Compliance amongst exercisers was 86.7+/-10.6%. Peak ground reaction forces during exercise increased from 2.5 to 2.8 times body weight. The change in femoral neck BMD in the exercise limb (adjusted for change in the control limb and baseline BMD) differed between groups (p=0.015), being -0.3% (-1.2 to 0.6), 0.0% (-1.0 to 1.0), 0.9% (-0.1 to 2.0) and 1.8% (0.8 to 2.8) in those exercising 0, 2, 4 and 7 days per week, respectively. When BMD changes at upper neck, lower neck and trochanter were compared using RM-MANOVA, a significant exercise effect was observed (p=0.048), but this did not differ significantly between sites (p=0.439) despite greatest mean increases at the upper femoral neck. Brief, daily hopping exercises increased femoral neck BMD in premenopausal women but less frequent exercise was not effective. Brief high-impact exercise may have a role in reducing hip fragility, but may need to be performed frequently for optimal response. Copyright 2009 Elsevier Inc. All rights reserved.
High Risk of Readmission in Octogenarians Undergoing Primary Hip Arthroplasty.
Malkani, Arthur L; Dilworth, Brian; Ong, Kevin; Baykal, Doruk; Lau, Edmund; Mackin, Theresa N; Lee, Gwo-Chin
2017-12-01
As life expectancy increases, more elderly patients with end-stage hip arthritis are electing to undergo primary THA. Octogenarians undergoing THA have more comorbidities than younger patients, but this is not reflected in risk adjustment models for bundled care programs. The burden of care associated with THA in octogenarians has not been well characterized, and doing so may help these value-based programs make adjustments so that this vulnerable patient population does not risk losing access under accountable care models. The purpose of this study was to describe care use, comorbidities, and complications among octogenarians undergoing primary THA. Five percent of the Medicare national administrative claims data was queried to identify patients diagnosed with hip osteoarthritis between January 1, 1998, and December 31, 2013. Patients who underwent primary THA were identified and followed longitudinally during the study period using their unique, encrypted Medicare beneficiary identifiers. We compared risk factors and complications between the octogenarian group versus those aged 65 to 69 years. Multivariate Cox regression was used to evaluate the effect of patient/hospital factors on risk of revision, periprosthetic joint infection, dislocation, venous thromboembolism (VTE), and mortality. Patient factors in the model included age, sex, race, region, socioeconomic status, and health status based on Charlson comorbidity score 12 months before replacement surgery. There were 11,960 THAs in the octogenarians in 1998, which increased to 21,620 in 2013, an 81% increase during this study period. Octogenarians were more likely to have a Charlson score of 3 or higher than those patients aged 65 to 69 years (30% versus 17%, odds ratio [OR] 2.07 [1.98-2.20]; p < 0.001), and they were more likely to have coronary artery disease or congestive heart failure (47% versus 29%, OR 2.16 [2.06-2.26]; p < 0.001). The octogenarian group had a greater risk of dislocation (+12%, p = 0.01), VTE (+14%, p < 0.001), and mortality (+150%, p < 0.001) compared with the younger age cohort. A total of 21% of the octogenarians were readmitted after surgery compared with 12% for patients in the younger group (OR=1.64, 95% confidence interval 1.54-1.75; p < 0.001). Because octogenarians are at increased risk of dislocation, VTE, medical complications, and mortality after THA, value-based care models that penalize hospitals for readmissions and complications may inadvertently result in loss of access to care for this group of patients as a result of the financial makeup of these bundled care models. Value-based care models were developed to improve care and decrease healthcare costs but may have unintended consequences in the octogenarian with higher complication and readmission risks. Financial losses may lead to institutions from withdrawing from the Bundled Payments for Care Improvement program. To try to prevent this from happening to this vulnerable patient population, bundled care programs should evolve and be modified to allow for risk stratification in the overall payment formula to account for increased age and comorbid conditions to ensure continued successful participation in the program among all the stakeholders. Level III, therapeutic study.
Low Frequency of Early Complications With Dual-mobility Acetabular Cups in Cementless Primary THA.
Chughtai, Morad; Mistry, Jaydev B; Diedrich, Aloise M; Jauregui, Julio J; Elmallah, Randa K; Bonutti, Peter M; Harwin, Steven F; Malkani, Arthur L; Kolisek, Frank R; Mont, Michael A
2016-10-01
Dislocation complicates 1% to 5% of primary total hip arthroplasties (THAs). As a result, some surgeons consider dual-mobility articulations, which are usually used in the revision setting to decrease the likelihood of dislocation, as an option for primary THA. However, few studies have evaluated their use in this setting. (1) What is the cup survivorship when the dual-mobility articulation is used in the setting of primary THA? (2) What are the clinical outcomes with this approach? (3) What are the radiographic outcomes? (4) What are the complications of dual-mobility articulations in primary THA? Between 2011 and 2013, the five participating surgeons performed 495 cementless primary THAs. During that time, one of the five surgeons used dual-mobility articulations for all THAs, and the other four used it whenever the acetabular cup size was 52 mm or greater to enable a 28-mm head. Of the 495 patients, 453 (92%) were performed using this device. Smaller patients were treated with a standard THA. Of the 453 patients, a total of 43 patients (10%) were lost to followup before the 2-year minimum. The resulting 410 patients who were included in the analysis (164 men, 246 women) had a mean age of 64 years (SD, 12 years). The mean followup was 3 years (SD, 0.7 years). We performed Kaplan-Meier analyses to assess survivorship to aseptic failure and all-cause acetabular component survivorship. Clinical outcomes were evaluated using the Harris hip score (HHS); radiographs were assessed for cup migration, progressive radiolucencies, and positional changes of the components; and any surgery-related complications were recorded. The survivorship to aseptic failure and all-cause acetabular component survivorship was 99.8% (failures, n = 1) (95% confidence interval [CI], 4.517-4.547) and 99.3% (failures, aseptic, n = 1; septic, n = 2) (95% CI, 4.494-4.543); one hip had trunnion notching caused by impingement of a malpositioned cup, which was treated with revision of the cup and stem; and two patients had periprosthetic infections that were treated with two-stage revisions. There were no dislocations. Patients had a mean HHS of 94 (SD, 6) at final followup. On radiographic evaluation, no progressive radiolucencies or positional changes of the components were identified. Surgical complications included one traumatic avulsion of the abductors, one traumatic avulsion of the greater trochanter, which was repaired without revision of any of the components, and one loose femoral stem, which required revision of the femoral component only. Dual-mobility cups in primary THA yield seemingly comparable survivorship and complications to conventional THA bearings at short-term followup. Because serious complications have occasionally been reported with the use of these bearings, larger, longer term, comparative-and ideally, randomized-trials will be needed to establish the superiority of one approach over the other. Until or unless such studies show the superiority of dual-mobility designs for primary THA, we recommend that in the setting of uncomplicated primary THA, dual-mobility articulations be used only in centers that track their results carefully or in research protocols. Level IV, therapeutic study.
What MRI Findings Predict Failure 10 Years After Surgery for Femoroacetabular Impingement?
Hanke, Markus S; Steppacher, Simon D; Anwander, Helen; Werlen, Stefan; Siebenrock, Klaus A; Tannast, Moritz
2017-04-01
Magnetic resonance arthrogram (MRA) with radial cuts is presently the best available preoperative imaging study to evaluate chondrolabral lesions in the setting of femoroacetabular impingement (FAI). Existing followup studies for surgical treatment of FAI have evaluated predictors of treatment failure based on preoperative clinical examination, intraoperative findings, and conventional radiography. However, to our knowledge, no study has examined whether any preoperative findings on MRA images might be associated with failure of surgical treatment of FAI in the long term. The purposes of this study were (1) to identify the preoperative MRA findings that are associated with conversion to THA, any progression of osteoarthritis, and/or a Harris hip score of < 80 points after acetabuloplasty and/or osteochondroplasty of the femoral head-neck junction through a surgical hip dislocation (SHD) for FAI at a minimum 10-year followup; and (2) identify the age of patients with symptomatic FAI when these secondary degenerative findings were detected on preoperative radial MRAs. We retrospectively studied 121 patients (146 hips) who underwent acetabuloplasty and/or osteochondroplasty of the femoral head-neck junction through SHD for symptomatic anterior FAI between July 2001 and March 2003. We excluded 35 patients (37 hips) with secondary FAI after previous surgery and 11 patients (12 hips) with Legg-Calvé-Perthes disease. All patients underwent preoperative MRA to further specify chondrolabral lesions except in 19 patients (32 hips) including 17 patients (20 hips) who presented with an MRI from an external institution taken with a different protocol, 10 patients with no preoperative MRA because the patients had already been operated on the contralateral side with a similar appearance, and two patients (two hips) refused MRA because of claustrophobia. This resulted in 56 patients (65 hips) with idiopathic FAI and a preoperative MRA. Of those, three patients (three hips) did not have minimal 10-year followup (one patient died; two hips with followup between 5 and 6 years). The remaining patients were evaluated clinically and radiographically at a mean followup of 11 years (range, 10-13 years). Thirteen pathologic radiographic findings on the preoperative MRA were evaluated for an association with the following endpoints using Cox regression analysis: conversion to THA, radiographic evidence of any progression of osteoarthritis, and/or a Harris hip score of < 80. The age of the patient when each degenerative pattern was found on the preoperative MRA was recorded. The following MRI findings were associated with one or more of our predefined failure endpoints: cartilage damage exceeding 60° of the circumference had a hazard ratio (HR) of 4.6 (95% confidence interval [CI], 3.6-5.6; p = 0.003) compared with a damage of less than 60°, presence of an acetabular rim cyst had a HR of 4.1 (95% CI, 3.1-5.2; p = 0.008) compared with hips without these cysts, and presence of a sabertooth osteophyte had a HR of 3.2 (95% CI, 2.3-4.2; p = 0.013) compared with hips without a sabertooth osteophyte. The degenerative pattern associated with the youngest patient age when detected on preoperative MRA was the sabertooth osteophyte (lower quartile 27 years) followed by cartilage damage exceeding 60° of the circumference (28 years) and the presence of an acetabular rim bone cyst (31 years). Preoperative MRAs with radial cuts reveal important findings that may be associated with future failure of surgical treatment for FAI. Most of these factors are not visible on conventional radiographs or standard hip MRIs. Preoperative MRA evaluation is therefore strongly recommended on a routine basis for patients undergoing these procedures. Findings associated with conversion to arthroplasty, radiographic evidence of any progression of osteoarthritis, and/or a Harris hip score of < 80 points should be incorporated into the decision-making process in patients being evaluated for joint-preserving hip surgery. Level III, therapeutic study.
Computer aided diagnosis and treatment planning for developmental dysplasia of the hip
NASA Astrophysics Data System (ADS)
Li, Bin; Lu, Hongbing; Cai, Wenli; Li, Xiang; Meng, Jie; Liang, Zhengrong
2005-04-01
The developmental dysplasia of the hip (DDH) is a congenital malformation affecting the proximal femurs and acetabulum that are subluxatable, dislocatable, and dislocated. Early diagnosis and treatment is important because failure to diagnose and improper treatment can result in significant morbidity. In this paper, we designed and implemented a computer aided system for the diagnosis and treatment planning of this disease. With the design, the patient received CT (computed tomography) or MRI (magnetic resonance imaging) scan first. A mixture-based PV partial-volume algorithm was applied to perform bone segmentation on CT image, followed by three-dimensional (3D) reconstruction and display of the segmented image, demonstrating the special relationship between the acetabulum and femurs for visual judgment. Several standard procedures, such as Salter procedure, Pemberton procedure and Femoral Shortening osteotomy, were simulated on the screen to rehearse a virtual treatment plan. Quantitative measurement of Acetabular Index (AI) and Femoral Neck Anteversion (FNA) were performed on the 3D image for evaluation of DDH and treatment plans. PC graphics-card GPU architecture was exploited to accelerate the 3D rendering and geometric manipulation. The prototype system was implemented on PC/Windows environment and is currently under clinical trial on patient datasets.
Do Changes in the Production Process Affect the Outcome of Ceramic Liners: A 3-Year Follow-Up Study.
Schmidt-Braekling, Tom; Renner, Lisa; Mintz, Douglas N; Waldstein, Wenzel; Endo, Yoshimi; Boettner, Friedrich
2017-04-01
In 2011, the current liner was withdrawn from the market because of the potential risk for liner fracture secondary to increased pressures used to assemble the metal locking ring. The present study provides a short-term follow-up of patients with this implant. We retrospectively evaluated 63 consecutive hips in 53 patients operated by a single surgeon using a recalled ceramic-on-ceramic bearing. There were 30 women and 23 men with an average age of 50.6 years (range 20.3-63.5 years). The mean follow-up was 36.8 months. Six hips in 6 patients were revised (9.5%) because of a liner-fracture during the follow-up period. All liner fractures were identified on computer tomography imaging. Nine patients had self-reported episodes of squeaking (14.3%). All 6 patients that underwent revision surgery for liner fracture described squeaking before revision. There were no revisions for other causes. Two of the revised patients had a subsequent dislocation (33%). The recalled ceramic liner lots have an increased liner fracture rate. Patients with mechanical symptoms or squeaking should undergo computer tomography to rule out liner facture. Copyright © 2016 Elsevier Inc. All rights reserved.
A new technique for radiographic measurement of acetabular cup orientation.
Derbyshire, Brian; Diggle, Peter J; Ingham, Christopher J; Macnair, Rory; Wimhurst, James; Jones, Henry Wynn
2014-02-01
Accurate radiographic measurement of acetabular cup orientation is required in order to assess susceptibility to impingement, dislocation, and edge loading wear. In this study, the accuracy and precision of a new radiographic cup orientation measurement system were assessed and compared to those of two commercially available systems. Two types of resurfacing hip prostheses and an uncemented prosthesis were assessed. Radiographic images of each prosthesis were created with the cup set at different, known angles of version and inclination in a measurement jig. The new system was the most accurate and precise and could repeatedly measure version and inclination to within a fraction of a degree. In addition it has a facility to distinguish cup retroversion from anteversion on anteroposterior radiographs. © 2013.
Oxidized zirconium on ceramic; Catastrophic coupling.
Ozden, V E; Saglam, N; Dikmen, G; Tozun, I R
2017-02-01
Oxidized zirconium (Oxinium™; Smith & Nephew, Memphis, TN, USA) articulated with polyethylene in total hip arthroplasty (THA) appeared to have the potential to reduce wear dramatically. The thermally oxidized metal zirconium surface is transformed into ceramic-like hard surface that is resistant to abrasion. The exposure of soft zirconium metal under hard coverage surface after the damage of oxidized zirconium femoral head has been described. It occurred following joint dislocation or in situ succeeding disengagement of polyethylene liner. We reported three cases of misuse of Oxinium™ (Smith & Nephew, Memphis, TN, USA) heads. These three cases resulted in catastrophic in situ wear and inevitable failure although there was no advice, indication or recommendation for this use from the manufacturer. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Siddiqui, Imran A; Sabah, Shiraz A; Satchithananda, Keshthra; Lim, Adrian K; Cro, Suzie; Henckel, Johann; Skinner, John A; Hart, Alister J
2014-08-01
Metal artifact reduction sequence (MARS) MRI and ultrasound scanning (USS) can both be used to detect pseudotumors, abductor muscle atrophy, and tendinous pathology in patients with painful metal-on-metal (MOM) hip arthroplasty. We wanted to determine the diagnostic test characteristics of USS using MARS MRI as a reference for detection of pseudotumors and muscle atrophy. PatienTS AND METHODS: We performed a prospective cohort study to compare MARS MRI and USS findings in 19 consecutive patients with unilateral MOM hips. Protocolized USS was performed by consultant musculoskeletal radiologists who were blinded regarding clinical details. Reports were independently compared with MARS MRI, the imaging gold standard, to calculate predictive values. The prevalence of pseudotumors on MARS MRI was 68% (95% CI: 43-87) and on USS it was 53% (CI: 29-76). The sensitivity of USS in detecting pseudotumors was 69% (CI 39-91) and the specificity was 83% (CI: 36-97). The sensitivity of detection of abductor muscle atrophy was 47% (CI: 24-71). In addition, joint effusion was detected in 10 cases by USS and none were seen by MARS MRI. We found a poor agreement between USS and MARS MRI. USS was inferior to MARS MRI for detection of pseudotumors and muscle atrophy, but it was superior for detection of joint effusion and tendinous pathologies. MARS MRI is more advantageous than USS for practical reasons, including preoperative planning and longitudinal comparison.
Atrophy of the quadriceps muscle in children with a painful hip.
Robben, S G; Lequin, M H; Meradji, M; Diepstraten, A F; Hop, W C
1999-09-01
The objective of this study was to determine the degree of muscle wasting of various components of the quadriceps muscle in children with a painful hip. Between January 1994 and September 1997, 327 consecutive children with a unilateral painful hip and/or limping were evaluated prospectively with ultrasonography. Quadriceps thickness was measured on both sides. Moreover, muscle thickness was measured in 59 control subjects. The patients were divided into eight groups; transient synovitis (n = 134), Perthes' disease (n = 35), slipped capital femoral epiphysis (n = 5), osteomyelitis (n = 4), aspecific synovitis (n = 5), rheumatoid arthritis (n = 3) and miscellaneous (n = 16). In 125 patients, no sonographic and radiological abnormalities were found and during follow-up the symptoms disappeared ('no pathology' group). Ipsilateral muscle wasting was present in all patient groups, whereas the control subjects showed no significant difference in muscle thickness between legs. The degree of muscle wasting was compared between transient synovitis, the 'no pathology' group, Perthes' disease and control subjects. For both quadriceps and vastus intermedius muscles, there was a significant difference between these groups, except between control subjects and the 'no pathology' group. For the rectus femoris muscle, there was a significant difference between these groups, except between transient synovitis and 'no pathology'. Muscle wasting showed a positive correlation with duration of symptoms and pre-existing muscle mass. In conclusion, different diseases show different degrees of muscle wasting, and there are different patterns of muscle wasting of various components of the quadriceps femoris muscle.
Haghighi, Kayvon; Manolakakis, Manolis G; Balog, Connor
2017-06-01
The aim of this study was to determine the feasibility of direct transcortical stabilization of fracture dislocations of the mandibular condyle (FDMCs) using narrow-diameter non-threaded Kirschner wire (K-wire). This retrospective review reports on the treatment outcomes for 12 patients (15 fractures) with FDMCs treated with open reduction using transcortical 0.027-inch K-wire stabilization. Postoperative parameters of relevance included infection, facial nerve function, hardware removal, mandibular range of motion, and radiographic determination of fracture union. Three patients had bilateral FDMCs and 9 had unilateral FDMCs (age range at time of injury, 14 to 72 yr; mean age, 32 yr). Postoperative follow-up ranged from 6 weeks to 2 years. Four patients required removal of K-wire hardware for different reasons. K-wires were removed because of infection in 1 patient. Another patient required removal because of migration of the pin into the joint space. One pin was removed electively and another was removed for nonspecific postoperative symptoms that resolved after pin removal. Persistent facial nerve deficit was observed in 1 patient. Open reduction with transcortical K-wire stabilization can achieve satisfactory outcomes for the treatment of FDMC. Further investigation is needed in determining the efficacy of this fixation technique in the management of FDMC. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Wacha, H; Domsel, G; Herrmann, E
2018-06-01
An arthroplasty registry in Germany has been recently established but long-term results for most short-stem innovations are missing. Short-stem hip arthroplasty is usually indicated in young active patients. Our indication was extended to older age groups, femoral neck fractures (FNF), and dysplasia. We evaluated all total hip arthroplasties (THAs) in this population with a collum femoris preserving stem (CFP) performed from 2003 to 2013. A consecutive cohort of 1217 CFP THAs with a mean age of 68.7 years was followed retrospectively for a median of 4.8 years (patient follow-up interquartile range from 3.0 to 6.9 years). A questionnaire, which we used in two previous studies, was answered by 89.15% of patients and included information regarding complaints, grade of satisfaction, re-operations, and dislocation. Of the 1217 patients, 77 had died. Survival of the stem and the cup was assessed using a competing risks approach according to an Aalen-Johanson estimator with revision for septic or aseptic loosening or death as a competing endpoint. Of the patients who answered the questionnaire, 92.5% had no complaints related to the procedures. In all 1217 patients, there were 43 revisions (4.2%) as follows: stem and cup revisions due to aseptic loosening of the stem (n = 10), infections (n = 6), pain (n = 4), or trauma (n = 3); cup revisions due to aseptic loosening (n = 3), dislocation (n = 5), and offset revisions (n = 12). Survivorship was 96% for the stem and 99% for the cup 9 years postoperatively. Statistical analysis confirmed a higher risk for revision in patients with a younger age (p = 0.033), male sex (p = 0.040), dysplasia (p = 0.032), and undersized or extra-large stems for stem revisions (p = 0.001) and female sex (p = 0.036) for cup revisions. FNF (p > 0.20) and age ≥ 80 years (p = 0.114) had no higher risk for loosening of the stem. Our data is also compared with the current literature, especially with the available CFP studies. The survival rate of the CFP stem was as high as 96% after 9 years of followup which compares well-to-previously published long-term survival rates. There is no higher risk for revision in patients 80 years old or older and in cases with femoral neck fractures. The CFP preserves also allowed using standard stems in the rare cases of revision.