Integration Process for the Habitat Demonstration Unit
NASA Technical Reports Server (NTRS)
Gill, Tracy; Merbitz, Jerad; Kennedy, Kriss; Tri, Terry; Howe, A. Scott
2010-01-01
The Habitat Demonstration Unit (HDU) is an experimental exploration habitat technology and architecture test platform designed for analog demonstration activities The HDU project has required a team to integrate a variety of contributions from NASA centers and outside collaborators and poses a challenge in integrating these disparate efforts into a cohesive architecture To complete the development of the HDU from conception in June 2009 to rollout for operations in July 2010, a cohesive integration strategy has been developed to integrate the various systems of HDU and the payloads, such as the Geology Lab, that those systems will support The utilization of interface design standards and uniquely tailored reviews have allowed for an accelerated design process Scheduled activities include early fit-checks and the utilization of a Habitat avionics test bed prior to equipment installation into HDU A coordinated effort to utilize modeling and simulation systems has aided in design and integration concept development Modeling tools have been effective in hardware systems layout, cable routing and length estimation, and human factors analysis Decision processes on the shell development including the assembly sequence and the transportation have been fleshed out early on HDU to maximize the efficiency of both integration and field operations Incremental test operations leading up to an integrated systems test allows for an orderly systems test program The HDU will begin its journey as an emulation of a Pressurized Excursion Module (PEM) for 2010 field testing and then may evolve to a Pressurized Core Module (PCM) for 2011 and later field tests, depending on agency architecture decisions The HDU deployment will vary slightly from current lunar architecture plans to include developmental hardware and software items and additional systems called opportunities for technology demonstration One of the HDU challenges has been designing to be prepared for the integration of presently unanticipated systems Results of the HDU field tests will influence future designs of habitat systems.
Habitat Demonstration Unit (HDU) Pressurized Excursion Module (PEM) Systems Integration Strategy
NASA Technical Reports Server (NTRS)
Gill, Tracy; Merbitz, Jerad; Kennedy, Kriss; Tri, Terry; Toups, Larry; Howe, A. Scott
2011-01-01
The Habitat Demonstration Unit (HDU) project team constructed an analog prototype lunar surface laboratory called the Pressurized Excursion Module (PEM). The prototype unit subsystems were integrated in a short amount of time, utilizing a rapid prototyping approach that brought together over 20 habitation-related technologies from a variety of NASA centers. This paper describes the system integration strategies and lessons learned, that allowed the PEM to be brought from paper design to working field prototype using a multi-center team. The system integration process was based on a rapid prototyping approach. Tailored design review and test and integration processes facilitated that approach. The use of collaboration tools including electronic tools as well as documentation enabled a geographically distributed team take a paper concept to an operational prototype in approximately one year. One of the major tools used in the integration strategy was a coordinated effort to accurately model all the subsystems using computer aided design (CAD), so conflicts were identified before physical components came together. A deliberate effort was made following the deployment of the HDU PEM for field operations to collect lessons learned to facilitate process improvement and inform the design of future flight or analog versions of habitat systems. Significant items within those lessons learned were limitations with the CAD integration approach and the impact of shell design on flexibility of placing systems within the HDU shell.
NASA Technical Reports Server (NTRS)
Tri, Terry O.; Kennedy, Kriss J.; Toups, Larry; Gill, Tracy R.; Howe, A. Scott
2011-01-01
This paper describes the construction, assembly, subsystem integration, transportation, and field testing operations associated with the Habitat Demonstration Unit (HDU) Pressurized Excursion Module (PEM) and discusses lessons learned. In a one-year period beginning summer 2009, a tightly scheduled design-develop-build process was utilized by a small NASA "tiger team" to produce the functional HDU-PEM prototype in time to participate in the 2010 Desert Research and Technology Studies (Desert RATS) field campaign. The process required the coordination of multiple teams, subcontractors, facility management and safety staff. It also required a well-choreographed material handling and transportation process to deliver the finished product from the NASA-Johnson Space Center facilities to the remote Arizona desert locations of the field test. Significant findings of this paper include the team s greater understanding of the HDU-PEM s many integration issues and the in-field training the team acquired which will enable the implementation of the next-generation of improvements and development of high-fidelity field operations in a harsh environment. The Desert RATS analog environment is being promoted by NASA as an efficient means to design, build, and integrate multiple technologies in a mission architecture context, with the eventual goal of evolving the technologies into robust flight hardware systems. The HDU-PEM in-field demonstration at Desert RATS 2010 provided a validation process for the integration team, which has already begun to retool for the 2011 field tests that require an adapted architecture.
Habitat Demonstration Unit Project Leadership and Management Strategies
NASA Technical Reports Server (NTRS)
Kennedy, Kriss J.
2011-01-01
This paper gives an overview of the National Aeronautics and Space Administration (NASA) led multi-center Habitat Demonstration Unit (HDU) project leadership and management strategies. The HDU project team constructed and tested an analog prototype lunar surface habitat/laboratory called the Pressurized Excursion Module (PEM) during 2010. The prototype unit subsystems were integrated in a short amount of time, utilizing a tiger team approach that brought together over 20 habitation-related technologies and innovations from a variety of NASA centers. This paper describes the leadership and management strategies as well as lessons learned pertaining to leading and managing a multi-center diverse team in a rapid prototype environment. The PEM configuration went from a paper design to an operational surface habitat demonstration unit in less than 12 months. The HDU project is part of the strategic plan from the Exploration Systems Mission Directorate (ESMD) Directorate Integration Office (DIO) and the Exploration Mission Systems Office (EMSO) to test destination elements in analog environments. The 2011 HDU-Deep Space Habitat (DSH) configuration will build upon the PEM work, and emphasize validity of crew operations (remote working and living), EVA operations, mission operations, logistics operations, and science operations that might be required in a deep space context for Near Earth Object (NEO) exploration mission architectures. The 2011 HDU-DSH will be field-tested during the 2011 Desert Research and Technologies Studies (DRaTS) field tests. The HDU project is a "technology-pull" project that integrates technologies and innovations from multiple NASA centers. This project will repurpose the HDU 2010 demo unit that was field tested in the 2010 DRaTS, adding habitation functionality to the prototype unit. This paper will describe the strategy of establishing a multi-center project management team that put in place the key multi-center leadership skills and disciplines to enable a successful tiger team approach. Advocacy was established with key stakeholders and NASA Headquarters (HQ) by defining a strategic vision, mission, goals and objectives for the project and team. As a technology-pull testbed capability the HDU project was able to collaborate and leverage the Exploration Technology Development Program (ETDP) and individual NASA center investments which capitalized on their respective center core competencies and skills. This approach enable the leveraging of over $7.5m of value to create an operational habitat demonstration unit 2010 PEM configuration.
NASA Technical Reports Server (NTRS)
Kennedy, Kriss J.; Toup, Larry; Gill, Tracy; Tri, Terry; Howe, Scott; Smitherman, David
2011-01-01
This paper gives an overview of the National Aeronautics and Space Administration (NASA) led multi-center Habitat Demonstration Unit (HDU) project leadership and management strategies being used by the NASA HDU team for a rapid prototyping project. The HDU project team constructed and tested an analog prototype lunar surface habitat/laboratory called the Pressurized Excursion Module (PEM) during 2010. The prototype unit subsystems were integrated in a short amount of time, utilizing a tiger team rapid prototyping approach that brought together over 20 habitation-related technologies and innovations from a variety of NASA centers. This paper describes the leadership and management strategies as well as lessons learned pertaining to leading and managing a multi-center diverse team in a rapid prototype environment. The PEM configuration went from a paper design to an operational surface habitat demonstration unit in less than 12 months. The HDU project is part of the strategic plan from the Exploration Systems Mission Directorate (ESMD) Directorate Integration Office (DIO) and the Exploration Mission Systems Office (EMSO) to test destination elements in analog environments. The 2011 HDU-Deep Space Habitat (DSH) configuration will build upon the PEM work, and emphasize validity of crew operations (remote working and living), EVA operations, mission operations, logistics operations, and science operations that might be required in a deep space context for Near Earth Object (NEO) exploration mission architectures. The 2011 HDU-DSH will be field-tested during the 2011 Desert Research and Technologies Studies (DRaTS) field tests. The HDU project is a "technology-pull" project that integrates technologies and innovations from multiple NASA centers. This project will repurpose the HDU 2010 demo unit that was field tested in the 2010 DRaTS, adding habitation functionality to the prototype unit. This paper will describe the strategy of establishing a multi-center project management team that put in place the key multi-center leadership skills and disciplines to enable a successful tiger team approach. Advocacy was established with key stakeholders and NASA Headquarters (HQ) by defining a strategic vision, mission, goals and objectives for the project and team. As a technology-pull testbed capability the HDU project was able to collaborate and leverage the Exploration Technology Development Program (ETDP) and individual NASA center investments which capitalized on their respective center core competencies and skills. This approach enable the leveraging of over $7.5m of value to create an operational habitat demonstration unit 2010 PEM configuration.
HDU Deep Space Habitat (DSH) Overview
NASA Technical Reports Server (NTRS)
Kennedy, Kriss J.
2011-01-01
This paper gives an overview of the National Aeronautics and Space Administration (NASA) led multi-center Habitat Demonstration Unit (HDU) project Deep Space Habitat (DSH) analog that will be field-tested during the 2011 Desert Research and Technologies Studies (D-RATS) field tests. The HDU project is a technology pull project that integrates technologies and innovations from multiple NASA centers. This project will repurpose the HDU Pressurized Excursion Module (PEM) that was field tested in the 2010 D-RATS, adding habitation functionality to the prototype unit. The 2010 configuration of the HDU-PEM consisted of a lunar surface laboratory module that was used to bring over 20 habitation-related technologies together in a single platform that could be tested as an advanced habitation analog in the context of mission architectures and surface operations. The 2011 HDU-DSH configuration will build upon the PEM work, and emphasize validity of crew operations (habitation and living, etc), EVA operations, mission operations, logistics operations, and science operations that might be required in a deep space context for Near Earth Object (NEO) exploration mission architectures. The HDU project consists of a multi-center team brought together in a skunkworks approach to quickly build and validate hardware in analog environments. The HDU project is part of the strategic plan from the Exploration Systems Mission Directorate (ESMD) Directorate Integration Office (DIO) and the Exploration Mission Systems Office (EMSO) to test destination elements in analog environments. The 2011 analog field test will include Multi Mission Space Exploration Vehicles (MMSEV) and the DSH among other demonstration elements to be brought together in a mission architecture context. This paper will describe overall objectives, various habitat configurations, strategic plan, and technology integration as it pertains to the 2011 field tests.
GeoLab's First Field Trials, 2010 Desert RATS: Evaluating Tools for Early Sample Characterization
NASA Technical Reports Server (NTRS)
Evans, Cindy A.; Bell, M. S.; Calaway, M. J.; Graff, Trevor; Young, Kelsey
2011-01-01
As part of an accelerated prototyping project to support science operations tests for future exploration missions, we designed and built a geological laboratory, GeoLab, that was integrated into NASA's first generation Habitat Demonstration Unit-1/Pressurized Excursion Module (HDU1-PEM). GeoLab includes a pressurized glovebox for transferring and handling samples collected on geological traverses, and a suite of instruments for collecting preliminary data to help characterize those samples. The GeoLab and the HDU1-PEM were tested for the first time as part of the 2010 Desert Research and Technology Studies (DRATS), NASA's analog field exercise for testing mission technologies. The HDU1- PEM and GeoLab participated in two weeks of joint operations in northern Arizona with two crewed rovers and the DRATS science team.
A Modular Instrumentation System for NASA's Habitat Demonstration Unit
NASA Technical Reports Server (NTRS)
Rojdev, Kristina; Kennedy, Kriss; Yim, Hester; Wagner, Raymond S.; Hong, Todd; Studor, George; Delaune, Paul
2010-01-01
NASA's human spaceflight program is focused on developing technologies to expand the reaches of human exploration and science activities beyond low earth orbit. A critical aspect of living in space or on planetary surfaces is habitation, which provides a safe and comfortable space in which humans can live and work. NASA is seeking out the best option for habitation by exploring several different concepts through the Habitat Demonstration Unit (HDU) project. The purpose of this HDU is to develop a fully autonomous habitation system that enables human exploration of space. One critical feature of the HDU project that helps to accomplish its mission of autonomy is the instrumentation system that monitors key subsystems operating within a Habitat configuration. The following paper will discuss previous instrumentation systems used in analog habitat concepts and how the current instrumentation system being implemented on the HDU1-PEM, or pressurized excursion module, is building upon the lessons learned of those previous systems. Additionally, this paper will discuss the benefits and the limitations of implementing a wireless sensor network (WSN) as the basis for data transport in the instrumentation system. Finally, this paper will address the experiences and lessons learned with integration, testing prior to deployment, and field testing at the JSC rock yard. NASA is developing the HDU1-PEM as a step towards a fully autonomous habitation system that enables human exploration of space. To accomplish this purpose, the HDU project is focusing on development, integration, testing, and evaluation of habitation systems. The HDU will be used as a technology pull, testbed, and integration environment in which to advance NASA's understanding of alternative mission architectures, requirements, and operations concepts definition and validation. This project is a multi-year effort. In 2010, the HDU1-PEM will be in a pressurized excursion module configuration, and in 2011 the module will be reconfigured for a pressurized core module configuration. Each year the HDU configurations will undergo testing at NASA's Desert Research and Technology Studies (D-RaTS) in Arizona [1]. As part of this project, a modular instrumentation system is developed to meet the monitoring needs of the HDU subsystems and to integrate with the current command and data handling infrastructure that has been developed for the project. The main objective of this study is to provide for the monitoring needs of the HDU. The requirements necessary to meet this objective are developed by working with the subsystem managers of the HDU to understand their monitoring needs. Additionally, the instrumentation system design leverages knowledge and lessons learned from previous studies, such as the inflatable habitat health monitoring system that was deployed in Antarctica [2], the integrated health monitoring system developed for NASA's Microhab [3], and the JSC Lunar Habitat Wireless Testbed to demonstrate a "standardsbased" approach to a wireless instrumentation system [4]. The HDU also requires flexibility in reconfiguration options, and it is necessary to demonstrate and evaluate a modular approach to an instrumentation system. Thus, the instrumentation system is designed in two parts: the primary system employs a standard WSN configuration, and the secondary system employs a wired USB hub. The WSN design provides for reconfiguration or replacement of sensors due to malfunctions or upgrades by using a wireless node that accepts ten instrument inputs and wirelessly transmits the data to the command and data handling system. The USB hub is necessary for those instruments that operate using a wired USB connection, although the design attempts to limit the amount of sensors that need to be wired connections.
The Habitat Demonstration Unit System Integration
NASA Technical Reports Server (NTRS)
Gill, Tracy R.; Kennedy, Kriss J.; Tri, Terry O.; Howe, Alan S.
2010-01-01
The Lunar Surface System Habitat Demonstration Unit (HDU) will require a project team to integrate a variety of contributions from National Aeronautics and Space Administration (NASA) centers and potential outside collaborators and poses a challenge in integrating these disparate efforts into a cohesive architecture. To accomplish the development of the first version of the HDU, the Pressurized Excursion Module (PEM), from conception in June 2009 to rollout for operations in July 2010, the HDU project team is using several strategies to mitigate risks and bring the separate efforts together. First, a set of design standards is being developed to define the interfaces between the various systems of PEM and to the payloads, such as the Geology Laboratory, that those systems will support. Scheduled activities such as early fit-checks and the utilization of a habitat avionics test bed prior to equipment installation into HDU PEM are planned to facilitate the integration process. A coordinated effort to establish simplified Computer Aided Design (CAD) standards and the utilization of a modeling and simulation systems will aid in design and integration concept development. Finally, decision processes on the shell development including the assembly sequence and the transportation have been fleshed out early on HDU design to maximize the efficiency of both integration and field operations.
Integration Process for the Habitat Demonstration Unit
NASA Technical Reports Server (NTRS)
Gill, Tracy; Merbitz, Jerad; Kennedy, Kriss; Tn, Terry; Toups, Larry; Howe, A. Scott; Smitherman, David
2011-01-01
The Habitat Demonstration Unit (HDU) is an experimental exploration habitat technology and architecture test platform designed for analog demonstration activities. The HDU previously served as a test bed for testing technologies and sub-systems in a terrestrial surface environment. in 2010 in the Pressurized Excursion Module (PEM) configuration. Due to the amount of work involved to make the HDU project successful, the HDU project has required a team to integrate a variety of contributions from NASA centers and outside collaborators The size of the team and number of systems involved With the HDU makes Integration a complicated process. However, because the HDU shell manufacturing is complete, the team has a head start on FY--11 integration activities and can focus on integrating upgrades to existing systems as well as integrating new additions. To complete the development of the FY-11 HDU from conception to rollout for operations in July 2011, a cohesive integration strategy has been developed to integrate the various systems of HDU and the payloads. The highlighted HDU work for FY-11 will focus on performing upgrades to the PEM configuration, adding the X-Hab as a second level, adding a new porch providing the astronauts a larger work area outside the HDU for EVA preparations, and adding a Hygiene module. Together these upgrades result in a prototype configuration of the Deep Space Habitat (DSH), an element under evaluation by NASA's Human Exploration Framework Team (HEFT) Scheduled activates include early fit-checks and the utilization of a Habitat avionics test bed prior to installation into HDU. A coordinated effort to utilize modeling and simulation systems has aided in design and integration concept development. Modeling tools have been effective in hardware systems layout, cable routing, sub-system interface length estimation and human factors analysis. Decision processes on integration and use of all new subsystems will be defined early in the project to maximize the efficiency of both integration and field operations. In addition a series of tailored design reviews are utilized to quickly define the systems and their integration into the DSH configuration. These processes are necessary to ensure activities, such as partially reversing integration of the X-Hab second story of the HDU and deploying and stowing the new work porch for transportation to the JSC Rock Yard and to the Arizona Black Point Lava Flow Site are performed with minimal or no complications. In addition, incremental test operations leading up to an Integrated systems test allows for an orderly systems test program. For FY-11 activities, the HDU DSH will act as a laboratory utilizing a new X-Hab inflatable second floor with crew habitation features. In addition to the day to day operations involving maintenance of the HDU and exploring the surrounding terrain, testing and optimizing the use of the new X-Hab, work porch, Hygiene Module, and other sub-system enhancements will be the focus of the FY-11 test objectives. The HDU team requires a successful integration strategy using a variety of tools and approaches to prepare the DSH for these test objectives. In a challenging environment where the prototyping influences the system design, as well as Vice versa, results of the HDU DSH field tests will influence future designs of habitat systems.
The Habitat Demonstration Unit Project: A Modular Instrumentation System for a Deep Space Habitat
NASA Technical Reports Server (NTRS)
Rojdev, Kristina; Kennedy, Kriss J.; Yim, Hester; Williamsn, Robert M.; Hafermalz, Scott; Wagner, Raymond S.
2011-01-01
NASA is focused on developing human exploration capabilities in low Earth orbit (LEO), expanding to near Earth asteroids (NEA), and finally to Mars. Habitation is a crucial aspect of human exploration, and a current focus of NASA activities. The Habitation Demonstration Unit (HDU) is a project focused on developing an autonomous habitation system that enables human exploration of space by providing engineers and scientists with a test bed to develop, integrate, test, and evaluate habitation systems. A critical feature of the HDU is the instrumentation system, which monitors key subsystems within the habitat. The following paper will discuss the HDU instrumentation system performance and lessons learned during the 2010 Desert Research and Technology Studies (D-RaTS). In addition, this paper will discuss the evolution of the instrumentation system to support the 2011 Deep Space Habitat configuration, the challenges, and the lessons learned of implementing this configuration. In 2010, the HDU was implemented as a pressurized excursion module (PEM) and was tested at NASA s D-RaTS in Arizona [1]. For this initial configuration, the instrumentation system design used features that were successful in previous habitat instrumentation projects, while also considering challenges, and implementing lessons learned [2]. The main feature of the PEM instrumentation system was the use of a standards-based wireless sensor node (WSN), implementing an IEEE 802.15.4 protocol. Many of the instruments were connected to several WSNs, which wirelessly transmitted data to the command and data handling system via a mesh network. The PEM instrumentation system monitored the HDU during field tests at D-RaTS, and the WSN data was later analyzed to understand the performance of this system. In addition, several lessons learned were gained from the field test experience, which fed into the instrumentation design of the next generation of the HDU.
Habitat Demonstration Unit (HDU) Vertical Cylinder Habitat
NASA Technical Reports Server (NTRS)
Howe, Alan; Kennedy, Kriss J.; Gill, Tracy R.; Tri, Terry O.; Toups, Larry; Howard, Robert I.; Spexarth, Gary R.; Cavanaugh, Stephen; Langford, William M.; Dorsey, John T.
2014-01-01
NASA's Constellation Architecture Team defined an outpost scenario optimized for intensive mobility that uses small, highly mobile pressurized rovers supported by portable habitat modules that can be carried between locations of interest on the lunar surface. A compact vertical cylinder characterizes the habitat concept, where the large diameter maximizes usable flat floor area optimized for a gravity environment and allows for efficient internal layout. The module was sized to fit into payload fairings for the Constellation Ares V launch vehicle, and optimized for surface transport carried by the All-Terrain Hex-Limbed Extra-Terrestrial Explorer (ATHLETE) mobility system. Launch and other loads are carried through the barrel to a top and bottom truss that interfaces with a structural support unit (SSU). The SSU contains self-leveling feet and docking interfaces for Tri-ATHLETE grasping and heavy lift. A pressurized module needed to be created that was appropriate for the lunar environment, could be easily relocated to new locations, and could be docked together in multiples for expanding pressurized volume in a lunar outpost. It was determined that horizontally oriented pressure vessels did not optimize floor area, which takes advantage of the gravity vector for full use. Hybrid hard-inflatable habitats added an unproven degree of complexity that may eventually be worked out. Other versions of vertically oriented pressure vessels were either too big, bulky, or did not optimize floor area. The purpose of the HDU vertical habitat module is to provide pressurized units that can be docked together in a modular way for lunar outpost pressurized volume expansion, and allow for other vehicles, rovers, and modules to be attached to the outpost to allow for IVA (intra-vehicular activity) transfer between them. The module is a vertically oriented cylinder with a large radius to allow for maximal floor area and use of volume. The modular, 5- m-diameter HDU vertical habitat module consists of a 2-m-high barrel with 0.6-mhigh end domes forming the 56-cubicmeter pressure vessel, and a 19-squaremeter floor area. The module has up to four docking ports located orthogonally from each other around the perimeter, and up to one docking port each on the top or bottom end domes. In addition, the module has mounting trusses top and bottom for equipment, and to allow docking with the ATHLETE mobility system. Novel or unique features of the HDU vertical habitat module include the nodelike function with multiple pressure hatches for docking with other versions of itself and other modules and vehicles; the capacity to be carried by an ATHLETE mobility system; and the ability to attach inflatable 'attic' domes to the top for additional pressurized volume.
Betten, Jan; Roness, Aleksander Kirkerud; Endreseth, Birger Henning; Trønnes, Håkon; Tyvold, Stig Sverre; Klepstad, Pål; Nordseth, Trond
2016-04-01
Admittance to a high dependency unit (HDU) is expensive. Patients who receive surgical treatment with 'low anterior resection of the rectum' (LAR) or 'abdominoperineal resection of the rectum' (APR) at our hospital are routinely treated in an HDU the first 16-24 h of the postoperative (PO) period. The aim of this study was to describe the extent of HDU-specific interventions given. We included patients treated with LAR or APR at the St. Olav University Hospital (Trondheim, Norway) over a 1-year period. Physiologic data and HDU-interventions recorded during the PO-period were obtained from the anesthesia information management system (AIMS). HDU-specific interventions were defined as the need for respiratory support, fluid replacement therapy >500 ml/h, vasoactive medications, or a need for high dose opioids (morphine >7.5 mg/h i.v.). Sixty-two patients were included. Most patients needed HDU-specific interventions during the first 6 h of the PO period. After this, one-third of the patients needed one or more of the HDU-specific interventions for shorter periods of time. Another one-third of the patients had a need for HDU-specific therapies for more than ten consecutive hours, primarily an infusion of nor-epinephrine. Most patients treated with LAR or APR was in need of an HDU-specific intervention during the first 6 h of the PO-period, with a marked decline after this time period. The applied methodology, using an AIMS, demonstrates that there is great variability in individual patients' postoperative needs after major surgery, and that these needs are dynamic in their nature.
NASA Habitat Demonstration Unit (HDU) Deep Space Habitat Analog
NASA Technical Reports Server (NTRS)
Howe, A. Scott; Kennedy, Kriss J.; Gill, Tracy
2013-01-01
The NASA Habitat Demonstration Unit (HDU) vertical cylinder habitat was established as a exploration habitat testbed platform for integration and testing of a variety of technologies and subsystems that will be required in a human-occupied planetary surface outpost or Deep Space Habitat (DSH). The HDU functioned as a medium-fidelity habitat prototype from 2010-2012 and allowed teams from all over NASA to collaborate on field analog missions, mission operations tests, and system integration tests to help shake out equipment and provide feedback for technology development cycles and crew training. This paper documents the final 2012 configuration of the HDU, and discusses some of the testing that took place. Though much of the higher-fidelity functionality has 'graduated' into other NASA programs, as of this writing the HDU, renamed Human Exploration Research Analog (HERA), will continue to be available as a volumetric and operational mockup for NASA Human Research Program (HRP) research from 2013 onward.
Integration of the Electrodynamic Dust Shield on a Lunar Habitat Demonstration Unit
NASA Technical Reports Server (NTRS)
Calle, C. I.; Immer, C. D.; Ferreira, J.; Hogue, M. D.; Chen, A.; Csonka, M. W.; VanSuetendael, N.; Snyder, S. J.
2010-01-01
NASA is developing a Habitat Demonstration Unit (HDU) to investigate the feasibility of lunar surface technologies and lunar ground operations. The HDU will define and validate lunar scenario architecture through field analog testing. It will contain a four-port vertical habitat module with docking demonstration capabilities. The Electrodynamic Oust Shield (EDS) is being incorporated into the HDU to demonstrate dust removal from a viewport and from a door prior to docking procedures. In this paper, we will describe our efforts to scale up the EDS to protect a viewport 20 cm in diameter. We will also describe the development of several 20 cm x 25 cm EDS patches to demonstrate dust removal from one of the HDU doors.
State-of-the-art HDU's critical importance.
Green, Philip
2012-09-01
Phil Green, senior project engineer at independent building services company, Shepherd Engineering Services (SES), describes SES's creation a new 'state-of-the-art', 4.5 million sterling pounds, high dependency unit (HDU) at The James Cook University Hospital, Middlesbrough. Completion of the 16-bed HDU, part of a wider South Tees Hospitals NHS Foundation Trust investment programme to remodel and enhance the hospital's facilities, follows last September's completion, also by SES, of the Endeavour Unit (HEJ - November 2011), a new oncology satellite building built as a key element of the Trust's 30 million sterling pounds expansion and redevelopment of its Radiotherapy Unit at the Middlesbrough hospital.
The Habitat Demonstration Unit Project Overview
NASA Technical Reports Server (NTRS)
Kennedy, Kriss J.; Grill, Tracy R.; Tri, Terry O.; Howe, Alan S.
2010-01-01
This paper will describe an overview of the National Aeronautics and Space Administration (NASA) led multi-center Habitat Demonstration Unit (HDU) Project. The HDU project is a "technology-pull" project that integrates technologies and innovations from numerous NASA centers. This project will be used to investigate and validate surface architectures, operations concepts, and requirements definition of various habitation concepts. The first habitation configuration this project will build and test is the Pressurized Excursion Module (PEM). This habitat configuration - the PEM - is based on the Constellation Architecture Scenario 12.1 concept of a vertically oriented habitat module. The HDU project will be tested as part of the 2010 Desert Research and Technologies Simulations (D-RATS) test objectives. The purpose of this project is to develop, integrate, test, and evaluate a habitat configuration in the context of the mission architectures and surface operation concepts. A multi-center approach will be leveraged to build, integrate, and test the PEM through a shared collaborative effort of multiple NASA centers. The HDU project is part of the strategic plan from the Exploration Systems Mission Directorate (ESMD) Directorate Integration Office (DIO) and the Lunar Surface Systems Project Office (LSSPO) to test surface elements in a surface analog environment. The 2010 analog field test will include two Lunar Electric Rovers (LER) and the PEM among other surface demonstration elements. This paper will describe the overall objectives, its various habitat configurations, strategic plan, and technology integration as it pertains to the 2010 and 2011 field analog tests. To accomplish the development of the PEM from conception in June 2009 to rollout for operations in July 2010, the HDU project team is using a set of design standards to define the interfaces between the various systems of PEM and to the payloads, such as the Geology Lab, that those systems will support. Scheduled activities such as early fit-checks and the utilization of a habitat avionics test bed prior to equipment installation into PEM are planned to facilitate the integration process.
NASA Technical Reports Server (NTRS)
Colozza, Anthony J.; George, Pat; Gambrell, Ronnie; Chapman, Chris
2013-01-01
A habitat demonstration unit (HDU) was constructed at NASA Johnson Space Center (JSC) and designed by a multicenter NASA team led out of NASA Kennedy Space Center (KSC). The HDU was subsequently utilized at the 2010 Desert Research and Technology Studies (RATS) program held at the Black Point Lava Flow in Arizona. This report describes the power system design, installation and operation for the HDU. The requirements for the power system were to provide 120 VAC, 28 VDC, and 120 VDC power to the various loads within the HDU. It also needed to be capable of providing power control and real-time operational data on the load's power consumption. The power system had to be capable of operating off of a 3 phase 480 VAC generator as well as 2 solar photovoltaic (PV) power systems. The system operated well during the 2 week Desert RATS campaign and met all of the main goals of the system. The power system is being further developed to meet the future needs of the HDU and options for this further development are discussed.
NASA Technical Reports Server (NTRS)
Barbeau, Zack
2011-01-01
The Habitat Demonstration Unit, or HDU, is a multi-purpose test bed that allows NASA scientists and engineers to design, develop, and test new living quarters, laboratories, and workspaces for the next generation space mission. Previous testing and integration has occurred during 2010 at the annual Desert Research and Technology Studies (Desert RATS) field testing campaign in the Arizona desert. There the HDU team tests the configuration developed for the fiscal year, or FY configuration. For FY2011, the NASA mission calls for simulating a deep space condition. The HDU-DSH, or Deep Space Habitat, will be configured with new systems and modules that will outfit the test bed with new deep space capabilities. One such addition is the new X-HAB (eXploration Habitat) Inflatable Loft. With any deep space mission there is the need for safe, suitable living quarters. The current HDU configuration does not allow for any living space at all. In fact, Desert RATS 2010 saw the crew sleeping in the Space Exploration Vehicles (SEV) instead of the HDU. The X-HAB Challenge pitted three universities against each other: Oklahoma State University, University of Maryland, and the University of Wisconsin. The winning team will have their design implemented by NASA for field testing at DRATS 2011. This paper will highlight the primary objective of getting the X-HAB field ready which involves the implementation of an elevator/handrail system along with smaller logistical and integration tasks associated with getting the HDU-DSH ready for shipment to DRATS.
Davidovic-Grigoraki, Miona; Thomakos, Nikolaos; Haidopoulos, Dimitrios; Vlahos, Giorgos; Rodolakis, Alexandros
2017-03-01
Routine post-operative care in high dependency unit (HDU), surgical intensive care unit (SICU) and intensive care unit (ICU) after high-risk gynaecological oncology surgical procedures may allow for greater recognition and correct management of post-operative complications, thereby reducing long-term morbidity and mortality. On the other hand, unnecessary admissions to these units lead to increased morbidity - nosocomial infections, increased length of hospital stay and higher hospital costs. Gynaecological oncology surgeons continue to look after their patient in the HDU/SICU and have the final role in decision-making on day-to-day basis, making it important to be well versed in critical care management and ensure the best care for their patients. Post-operative monitoring and the presence of comorbid illnesses are the most common reasons for admission to the HDU/SICU. Elderly and malnutritioned patients, as well as, bowel resection, blood loss or greater fluid resuscitation during the surgery have prolonged HDU/SICU stay. Patients with ovarian cancer have a worse survival outcome than the patients with other types of gynaecological cancer. Dependency care is a part of surgical management and it should be incorporated formally into gynaecologic oncology training programme. © 2016 John Wiley & Sons Ltd.
1987-07-01
ederick, MD 21701-5012- M WPUM TPOSONINGOFFICE SYMBOL 9 PROCUREMENT INSTRUMENT IDENTIFICATION NUMBER ORGANTICIN(i soppkablo) &L. ADUSS (City umat . and W...distortion, improperly positioned helmet electronics, or damaged HDU receiver assembly, 9 and HDU optical axis misalignment due to a bent combiner or...internal damage to the HDU lens assembly. All components were contractoLr supplied. The scheduling of a fitting session required coordination between
Debris Impact Detection Instrument for Crewed Modules
NASA Technical Reports Server (NTRS)
Opiela, J.; Corsaro, R.; Giovanes, F.; Lio, J.-C.
2012-01-01
When micrometeoroid or debris impacts occur on a space habitat, crew members need to be quickly informed of the likely extent of damage, and be directed to the impact location for possible repairs. This is especially important because the outer walls of pressurized volumes are often not easily accessible, blocked by racks or cabinets. The goal of the Habitat Particle Impact Monitoring System (HIMS) is to develop a fully automated, end-to-end particle impact detection system for crewed space exploration modules. The HIMS uses multiple passive, thin film piezo-polymer vibration sensors to detect impacts on a surface, and computer processing of the acoustical signals to characterize the impacts. Development and demonstration of the HIMS is proceeding in concert with NASA's Habitat Demonstration Unit (HDU) Project. The HDU Project is designed to develop and test various technologies, configurations, and operational concepts for exploration habitats. This paper describes the HIMS development, initial testing, and HDU integration efforts. Initial tests of the system on the HDU were conducted at NASA s 2010 and 2011 Desert Research and Technologies Studies (Desert-RATS or D-RATS). The HDU lab module, as seen from above, has an open circular floorplan divided into eight wedge-shaped Segments. The side wall of the module -- the surface used for this technology demonstration -- is a hard fiberglass composite covered with a layer of sprayed-on foam insulation. Four sensor locations were assigned near the corners of a rectangular pattern on the wall of one segment of the HDU lab module. The flat, self-adhesive sensors were applied to the module during its initial outfitting. To study the influence of the wall s construction (thickness and materials), three sets of four sensors were installed at different layer depths: on the interior of the module s wall, on the exterior of the same wall, and on the exterior of the foam insulation. The signal produced when a vibration passes through a sensor is first sent through a pre-amplifier. The amplified signal then is sent to the data acquisition and data processing systems. The vibration data from the sensors are then processed and reduced to a form suitable for presentation to the crew.
HDU Pressurized Excursion Module (PEM) Prototype Systems Integration
NASA Technical Reports Server (NTRS)
Gill, Tracy R.; Kennedy, Kriss; Tri, Terry; Toups, Larry; Howe, A. Scott
2010-01-01
The Habitat Demonstration Unit (HDU) project team constructed an analog prototype lunar surface laboratory called the Pressurized Excursion Module (PEM). The prototype unit subsystems were integrated in a short amount of time, utilizing a skunk-works approach that brought together over 20 habitation-related technologies from a variety of NASA centers. This paper describes the system integration strategies and lessons learned, that allowed the PEM to be brought from paper design to working field prototype using a multi-center team. The system integration process included establishment of design standards, negotiation of interfaces between subsystems, and scheduling fit checks and installation activities. A major tool used in integration was a coordinated effort to accurately model all the subsystems using CAD, so that conflicts were identified before physical components came together. Some of the major conclusions showed that up-front modularity that emerged as an artifact of construction, such as the eight 45 degree "pie slices" making up the module whose steel rib edges defined structural mounting and loading points, dictated much of the configurational interfaces between the major subsystems and workstations. Therefore, 'one of the lessons learned included the need to use modularity as a tool for organization in advance, and to work harder to prevent non-critical aspects of the platform from dictating the modularity that may eventually inform the fight system.
Grewal, Harjeet; Varshney, Kavita; Thomas, Lee C; Kok, Jen; Shetty, Amith
2013-06-01
Blood pressure (BP) cuffs are potential vectors for transmission of multi-resistant organisms (MROs). The present study aims to determine MRO colonisation rates in BP cuffs from areas of high patient flow as an assessment of the quality of disinfection and infection control practices. BP cuffs in the ED, high dependency unit (HDU) and operating theatres (OT) were prospectively examined after routine disinfection procedures. Swabs collected from the inner and outer surfaces of BP cuffs during inter-patient intervals were plated onto replicate organism detection and counting, methicillin-resistant Staphylococcus aureus (MRSA) and vancomycin-resistant Enterococcus (VRE) chromogenic agar plates to detect rates of bacterial, MRSA and VRE colonisation, respectively. High bacterial colonisation rates were detected in BP cuffs from all three areas. BP cuffs from OT were significantly less colonised compared with cuffs from HDU and ED; 76% versus 96% and 100% (P < 0.0001) for inner surfaces and 86% versus 98% and 100% (P < 0.0001) for outer surfaces, respectively. Equivalent or higher bacterial growth was observed on the inner surface compared with outer surface in 54%, 84% and 86% of BP cuffs from OT, HDU and ED, respectively. MRSA was detected in 3 of 150 (2%) swabs collected, but no VRE was detected. Although MRSA and VRE were infrequently isolated, current disinfection and infection control protocols need to be improved given the greater recovery of organisms from the inner compared with outer surfaces of BP cuffs. © 2013 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.
Radial Internal Material Handling System (RIMS) for Circular Habitat Volumes
NASA Technical Reports Server (NTRS)
Howe, Alan S.; Haselschwardt, Sally; Bogatko, Alex; Humphrey, Brian; Patel, Amit
2013-01-01
On planetary surfaces, pressurized human habitable volumes will require a means to carry equipment around within the volume of the habitat, regardless of the partial gravity (Earth, Moon, Mars, etc.). On the NASA Habitat Demonstration Unit (HDU), a vertical cylindrical volume, it was determined that a variety of heavy items would need to be carried back and forth from deployed locations to the General Maintenance Work Station (GMWS) when in need of repair, and other equipment may need to be carried inside for repairs, such as rover parts and other external equipment. The vertical cylindrical volume of the HDU lent itself to a circular overhead track and hoist system that allows lifting of heavy objects from anywhere in the habitat to any other point in the habitat interior. In addition, the system is able to hand-off lifted items to other material handling systems through the side hatches, such as through an airlock. The overhead system consists of two concentric circle tracks that have a movable beam between them. The beam has a hoist carriage that can move back and forth on the beam. Therefore, the entire system acts like a bridge crane curved around to meet itself in a circle. The novelty of the system is in its configuration, and how it interfaces with the volume of the HDU habitat. Similar to how a bridge crane allows coverage for an entire rectangular volume, the RIMS system covers a circular volume. The RIMS system is the first generation of what may be applied to future planetary surface vertical cylinder habitats on the Moon or on Mars.
NASA Astrophysics Data System (ADS)
Kong, Xiangdong; Ba, Kaixian; Yu, Bin; Cao, Yuan; Zhu, Qixin; Zhao, Hualong
2016-05-01
Each joint of hydraulic drive quadruped robot is driven by the hydraulic drive unit (HDU), and the contacting between the robot foot end and the ground is complex and variable, which increases the difficulty of force control inevitably. In the recent years, although many scholars researched some control methods such as disturbance rejection control, parameter self-adaptive control, impedance control and so on, to improve the force control performance of HDU, the robustness of the force control still needs improving. Therefore, how to simulate the complex and variable load characteristics of the environment structure and how to ensure HDU having excellent force control performance with the complex and variable load characteristics are key issues to be solved in this paper. The force control system mathematic model of HDU is established by the mechanism modeling method, and the theoretical models of a novel force control compensation method and a load characteristics simulation method under different environment structures are derived, considering the dynamic characteristics of the load stiffness and the load damping under different environment structures. Then, simulation effects of the variable load stiffness and load damping under the step and sinusoidal load force are analyzed experimentally on the HDU force control performance test platform, which provides the foundation for the force control compensation experiment research. In addition, the optimized PID control parameters are designed to make the HDU have better force control performance with suitable load stiffness and load damping, under which the force control compensation method is introduced, and the robustness of the force control system with several constant load characteristics and the variable load characteristics respectively are comparatively analyzed by experiment. The research results indicate that if the load characteristics are known, the force control compensation method presented in this paper has positive compensation effects on the load characteristics variation, i.e., this method decreases the effects of the load characteristics variation on the force control performance and enhances the force control system robustness with the constant PID parameters, thereby, the online PID parameters tuning control method which is complex needs not be adopted. All the above research provides theoretical and experimental foundation for the force control method of the quadruped robot joints with high robustness.
Using predicted 30 day mortality to plan postoperative colorectal surgery care: a cohort study.
Swart, M; Carlisle, J B; Goddard, J
2017-01-01
Preoperative identification of high-risk surgical patients might help to reduce postoperative morbidity and mortality. Using a patient's predicted 30 day mortality to plan postoperative high-dependency unit (HDU) care after elective colorectal surgery might be associated with reduced postoperative morbidity. The 30 day postoperative mortality was predicted for 504 elective colorectal surgical patients in a preoperative clinic. The prediction was used to determine postoperative surgical ward or HDU care. Those with a predicted 30 day mortality of 1-3% mortality, and thus deemed at intermediate risk, had either planned HDU care (n=68) or planned ward care (n=139). The main outcome measures were emergency laparotomy and unplanned critical care admission. There were more emergency laparotomies and unplanned critical care admissions in patients with a predicted 30 day mortality of 1-3% who went to an HDU after surgery compared with patients who went to a ward: 0 vs 14 (10%), P=0.0056 and 0 vs 22 (16%), P=0.0002, respectively. Planned postoperative critical care was associated with a lower rate of complications after elective colorectal surgery. © The Author 2016. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Management of hypoxaemic respiratory failure in a Respiratory High-dependency Unit.
Hukins, Craig; Wong, Mimi; Murphy, Michelle; Upham, John
2017-07-01
There are limited data on outcomes of hypoxaemic respiratory failure (HRF), especially in non-intensive care unit (ICU) settings. To assess outcomes in HRF (without multi-system disease and not requiring early intubation) of patients directly admitted to a Respiratory High-dependency Unit (R-HDU). This is a retrospective cohort study of HRF compared to hypercapnic respiratory failure (HCRF) in a R-HDU (2007-2011). Patient characteristics (age, gender, pre-morbid status, diagnoses) and outcomes (non-invasive ventilation (NIV) use, survival, ICU admission) were assessed. There were 1207 R-HDU admissions in 2007-2011, 205 (17%) with HRF and 495 (41%) with HCRF. The proportion with HRF increased from 12.2% in 2007 to 20.1% in 2011 (P < 0.05). HRF patients were younger, more often male and had better pre-morbid performance. Compared to HCRF, HRF was more frequently associated with lung consolidation (61% vs 15%, P < 0.001), interstitial lung disease (12% vs 1%, P < 0.001) and pulmonary hypertension (7% vs 0%, P < 0.001) and less frequently with chronic obstructive pulmonary disease (24% vs 65%, P < 0.001) and obstructive sleep apnoea (8% vs 26%, P < 0.001). Fewer patients with HRF were treated with NIV (28% vs 87%, P < 0.001), but NIV was discontinued early more often (28% vs 7%, P < 0.001). A total of 18% with HRF was transferred to ICU compared to 6% with HCRF (P = 0.06). More patients with HRF died (19.5% vs 12.3%, P = 0.02). Interstitial lung disease, consolidation, shock, malignancy and poorer pre-morbid function were associated with increased mortality. Initial R-HDU management is an effective option in selected HRF to reduce ICU demand, although mortality and clinical deterioration despite NIV are more common than in HCRF. © 2017 Royal Australasian College of Physicians.
Operational Evaluation of VEGGIE Food Production System in the Habitat Demonstration Unit
NASA Technical Reports Server (NTRS)
Stutte, Gary W.; Newsham, Gerard; Morrow, Robert M.; Wheeler, Raymond M.
2011-01-01
The 2010 Desert Research and Technology Studies (DRATS) of the VEGGIE Food Production System in the Habitat Demonstration Unit (HDU) Pressurized Excursion Module (PEM) was the first operational evaluation of salad crop production technology in a NASA analog test. A systematic evaluation of rooting media and nutrient delivery systems were evaluated for three lettuce cultivars that have shown promise as candidates for a surface based food production system. The VEGGIE nutrient delivery system worked well, was able to be maintained by multiple operators with a minimum of training, and supported excellent lettuce growth for the duration of the test. A Hazard Analysis and Critical Control Point (HACCP) evaluation was performed using ProSan(tm) as sanitation agent prior to consumption was approved, and the crew was allowed to consume the lettuce grown using the VEGGIE light cap and gravity based nutrient delivery system at the completion of the 14-day DRAT field test. The DRAT field test validated the crew operations; Growth of all lettuce cultivars was excellent. The operational DRAT field testing in the HDU identified light quality issues related to morphology and pigment development that will need to be addressed through additional testing. Feedback from the crew, ground support personnel, and human factors leads was uniformly positive on the psychological value of having the crop production system in the excursion module. A number of areas have been identified for future work, to minimize the "footprint" of the Food Production system through creative use of unused wall and floor space in the unit.
Operation Evaluation of the VEGGIE Food Production System in the Habitat Demonstration Unit
NASA Technical Reports Server (NTRS)
Stutte, Gary W.; Newsham, Gerard; Morrow, Robert M.; Wheeler, Raymond M.
2011-01-01
The 2010 Desert Research and Technology Studies (DRATS) of the VEGGIE Food Production System in the Habitat Demonstration Unit (HDU) Pressurized Excursion Module (PEM) was the first operational evaluation of salad crop production technology in a NASA analog test. A systematic evaluation of rooting media and nutrient delivery systems were evaluated for three lettuce cultivars that have shown promise as candidates for a surface based food production system. The VEGGIE nutrient delivery system worked well, was able to be maintained by multiple operators with a minimum of training, and supported excellent lettuce growth for the duration of the test. A Hazard Analysis and Critical Control Point (HACCP) evaluation was performed using ProSantm as sanitation agent prior to consumption was approved, and the crew was allowed to consume the lettuce grown using the VEGGIE light cap and gravity based nutrient delivery system at the completion of the 14-day DRAT field test. The DRAT field test validated the crew operations; Growth of all lettuce cultivars was excellent. The operational DRAT field testing in the HDU identified light quality issues related to morphology and pigment development that will need to be addressed through additional testing. Feedback from the crew, ground support personnel, and human factors leads was uniformly positive on the psychological value of having the crop production system in the excursion module. A number of areas have been identified for future work, to minimize the "footprint" of the Food Production system through creative use of unused wall and floor space in the unit.
Digital ulcers predict a worse disease course in patients with systemic sclerosis.
Mihai, Carina; Landewé, Robert; van der Heijde, Désirée; Walker, Ulrich A; Constantin, Paul I; Gherghe, Ana Maria; Ionescu, Ruxandra; Rednic, Simona; Allanore, Yannick; Avouac, Jérôme; Czirják, László; Hachulla, Eric; Riemekasten, Gabriela; Cozzi, Franco; Airò, Paolo; Cutolo, Maurizio; Mueller-Ladner, Ulf; Matucci-Cerinic, Marco
2016-04-01
Systemic sclerosis (SSc) is a systemic autoimmune disease with high morbidity and significant mortality. There is a great need of predictors that would allow risk stratification of patients with SSc and ultimately initiation of treatment early enough to ensure optimal clinical results. In this study, we evaluated whether a history of digital ulcers (HDU) at presentation may be a predictor of vascular outcomes and of overall clinical worsening and death in patients with SSc. Patients from the EULAR Scleroderma Trials and Research (EUSTAR) database, satisfying at inclusion the 1980 American College of Rheumatology classification criteria for SSc, who had a follow-up of at least 3 years since baseline or who have died, were included in the analysis. HDU at presentation as a predictor of disease worsening or death was evaluated by Cox proportional hazards regression analysis. 3196 patients matched the inclusion criteria (male sex 13.2%, 33.4% diffuse subset). At presentation, 1092/3196 patients had an HDU (34.1%). In multivariable analysis adjusting for age, gender and all parameters considered potentially significant, HDU was predictive for the presence of active digital ulcers (DUs) at prospective visits (HR (95% CI)): 2.41 (1.91 to 3.03), p<0.001, for an elevated systolic pulmonary arterial pressure on heart ultrasound (US-PAPs):1.36 (1.03 to 1.80), p=0.032, for any cardiovascular event (new DUs, elevated US-PAPs or LV failure): 3.56 (2.26 to 5.62), p<0.001, and for death (1.53 (1.16 to 2.02), p=0.003). In patients with SSc, HDU at presentation predicts the occurrence of DUs at follow-up and is associated with cardiovascular worsening and decreased survival. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Human habitation field study of the Habitat Demonstration Unit (HDU)
NASA Astrophysics Data System (ADS)
Litaker, Harry L.; Archer, Ronald D.; Szabo, Richard; Twyford, Evan S.; Conlee, Carl S.; Howard, Robert L.
2013-10-01
Landing and supporting a permanent outpost on a planetary surface represents humankind's capability to expand its own horizons and challenge current technology. With this in mind, habitability of these structures becomes more essential given the longer durations of the missions. The purpose of this evaluation was to obtain preliminary human-in-the-loop performance data on the Habitat Demonstration Unit (HDU) in a Pressurized Excursion Module (PEM) configuration during a 14-day simulated lunar exploration field trial and to apply this knowledge to further enhance the habitat's capabilities for forward designs. Human factors engineers at the NASA/Johnson Space Center's Habitability and Human Factors Branch recorded approximately 96 h of crew task performance with four work stations. Human factors measures used during this study included the NASA Task Load Index (TLX) and customized post questionnaires. Overall the volume for the PEM was considered acceptable by the crew; however; the habitat's individual work station volume was constrained when setting up the vehicle for operation, medical operations, and suit maintenance while general maintenance, logistical resupply, and geo science was considered acceptable. Crew workload for each station indicated resupply as being the lowest rated, with medical operations, general maintenance, and geo science tasks as being light, while suit maintenance was considered moderate and general vehicle setup being rated the highest. Stowage was an issue around the habitat with the Space Exploration Vehicle (SEV) resupply stowage located in the center of the habitat as interfering with some work station volumes and activities. Ergonomics of the geo science station was considered a major issue, especially with the overhead touch screens.
Growth of Three Lettuce Cultivars in NASA's HDU PEM During the 2010 DRATS Test
NASA Technical Reports Server (NTRS)
Stutte, Gary W.; Newsham, Gerard; Wheeler, Raymond
2011-01-01
NASA's 2010 Desert Research and Technology Studies (DRATS) of the VEGGIE Food Production System in the Habitat Demonstration Unit (HDU) Pressurized Excursion Module (PEM) was the first operational evaluation of salad crop production technology in a NASA analog test. Rooting media and slow release fertilizers were evaluated for three lettuce cultivars that had shown promise as candidates for a surface based food production system. These tests involved comparing growth, color and quality of the lettuce cultivars grown under VEGGIE LED array (Orbitec, Madison, WI) or Biomass Production System for Education ((BSEe), Orbitec, Madison, WI) compact fluorescent lamps using a gravity feed water delivery system. Mission relevant conditions of CO2, temperature and RH were maintained using controlled environment chambers (EGC, Chagrin Falls, OH). Growth data was obtained for the two red leaf lettuce cultivars, Outredgeous and Firecracker, and the green Bibb lettuce cultivar, Flandria. Growth and quality was evaluated using different concentrations (7.5 g/L and 15 g/L) of commercial slow release fertilizer (Osmocote Plus 15-9-12, Scotts, Maryville, OH) and Nutricote 18-6-8 (Florikan, Sarasota, FL) in either a peat/vermiculite media (sunshine LP5 MiX, Sungro, Bellview, WA) or calcined montmorillonite clay [(arcillite,)Turface Proleague, Profile LLC, Buffalo Grove, IL]. The commercial peat/vermiculite mix generally resulted in larger plants than those grown in arcillite. Increasing the concentration of Osmocote from 7.5 to 15 g/L increased the height, dry mass, and leaf area of lettuce cultivars. In contrast, there was a decrease in growth parameters when concentration of Nutricote was increased from 7.5 to 15 g/L. The best growth was obtained with the 7.5 g/L Nutricote using a commercial peat/vermiculite mixture. This media was used for field testing VEGGIE plant system in the 2010 DRAT test. The VEGGIE nutrient delivery system worked well, was able to be maintained by multiple operators with a minimum of training, and supported excellent lettuce growth for the duration of the 14-day test. The operational DRAT field testing in the HDU identified light quality issues related to morphology and pigment development that will need to be addressed through additional testing. Feedback from the crew, ground support personnel, and human factors leads was uniformly positive on the psychological value of having the crop production system in the pressurized excursion module. Data are being used to design a plant atrium with LED lighting to evaluate salad crop growth during NASA's 2011 DRATS test.
Price, James R; Cole, Kevin; Bexley, Andrew; Kostiou, Vasiliki; Eyre, David W; Golubchik, Tanya; Wilson, Daniel J; Crook, Derrick W; Walker, A Sarah; Peto, Timothy E A; Llewelyn, Martin J; Paul, John
2017-02-01
Health-care workers have been implicated in nosocomial outbreaks of Staphylococcus aureus, but the dearth of evidence from non-outbreak situations means that routine health-care worker screening and S aureus eradication are controversial. We aimed to determine how often S aureus is transmitted from health-care workers or the environment to patients in an intensive care unit (ICU) and a high-dependency unit (HDU) where standard infection control measures were in place. In this longitudinal cohort study, we systematically sampled health-care workers, the environment, and patients over 14 months at the ICU and HDU of the Royal Sussex County Hospital, Brighton, England. Nasal swabs were taken from health-care workers every 4 weeks, bed spaces were sampled monthly, and screening swabs were obtained from patients at admission to the ICU or HDU, weekly thereafter, and at discharge. Isolates were cultured and their whole genome sequenced, and we used the threshold of 40 single-nucleotide variants (SNVs) or fewer to define subtypes and infer recent transmission. Between Oct 31, 2011, and Dec 23, 2012, we sampled 198 health-care workers, 40 environmental locations, and 1854 patients; 1819 isolates were sequenced. Median nasal carriage rate of S aureus in health-care workers at 4-weekly timepoints was 36·9% (IQR 35·7-37·3), and 115 (58%) health-care workers had S aureus detected at least once during the study. S aureus was identified in 8-50% of environmental samples. 605 genetically distinct subtypes were identified (median SNV difference 273, IQR 162-399) at a rate of 38 (IQR 34-42) per 4-weekly cycle. Only 25 instances of transmission to patients (seven from health-care workers, two from the environment, and 16 from other patients) were detected. In the presence of standard infection control measures, health-care workers were infrequently sources of transmission to patients. S aureus epidemiology in the ICU and HDU is characterised by continuous ingress of distinct subtypes rather than transmission of genetically related strains. UK Medical Research Council, Wellcome Trust, Biotechnology and Biological Sciences Research Council, UK National Institute for Health Research, and Public Health England. Copyright © 2017 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY license. Published by Elsevier Ltd.. All rights reserved.
Dust Removal Technology Demonstration for a Lunar Habitat
NASA Technical Reports Server (NTRS)
Calle, C. I.; Chen, A.; Immer, C. D.; Csonka, M.; Hogue, M. D.; Snyder, S. J.; Rogriquez, M.; Margiotta, D. V.
2010-01-01
We have developed an Electrodynamic Dust Shield (EDS), an active dust mitigation technology with applications to solar panels, thermal radiators, optical systems, visors, seals and connectors. This active technology is capable of removing dust and granular material with diameters as large as several hundred microns. In this paper, we report on the development of three types of EDS systems for NASA's Habitat Demonstration Unit (HDU). A transparent EDS 20 cm in diameter with indium tin oxide electrodes on a 0.1 mm-thick polyethylene terephtalate (PET) film was constructed for viewport dust protection. Two opaque EDS systems with copper electrodes on 0.1 mm-thick Kapton were also built to demonstrate dust removal on the doors of the HDU. A lotus coating that minimizes dust adhesion was added to one of the last two EDS systems to demonstrate the effectiveness of the combined systems.
Geolab 2010: Desert Rats Field Demonstration
NASA Technical Reports Server (NTRS)
Evans, Cindy A.; Calaway, M. J.; Bell, M. S.
2009-01-01
In 2010, Desert Research and Technology Studies (Desert RATS), NASA's annual field exercise designed to test spacesuit and rover technologies, will include a first generation lunar habitat facility, the Habitat Demonstration Unit (HDU). The habitat will participate in joint operations in northern Arizona with the Lunar Electric Rover (LER) and will be used as a multi-use laboratory and working space. A Geology Laboratory or GeoLab is included in the HDU design. Historically, science participation in Desert RATS exercises has supported the technology demonstrations with geological traverse activities that are consistent with preliminary concepts for lunar surface science Extravehicular Activities (EVAs). Next year s HDU demonstration is a starting point to guide the development of requirements for the Lunar Surface Systems Program and test initial operational concepts for an early lunar excursion habitat that would follow geological traverses along with the LER. For the GeoLab, these objectives are specifically applied to support future geological surface science activities. The goal of our GeoLab is to enhance geological science returns with the infrastructure that supports preliminary examination, early analytical characterization of key samples, and high-grading lunar samples for return to Earth [1, 2] . Figure 1: Inside view schematic of the GeoLab a 1/8 section of the HDU, including a glovebox for handling and examining geological samples. Other outfitting facilities are not depicted in this figure. GeoLab Description: The centerpiece of the GeoLab is a glovebox, allowing for samples to be brought into the habitat in a protected environment for preliminary examination (see Fig. 1). The glovebox will be attached to the habitat bulkhead and contain three sample pass-through antechambers that would allow direct transfer of samples from outside the HDU to inside the glovebox. We will evaluate the need for redundant chambers, and other uses for the glovebox antechambers, such as a staging area for additional tools or samples. The sides of the glovebox are designed with instrument ports and additional smaller ports for cable pass-through, imagery feeds and environmental monitoring. This first glovebox version will be equipped with basic tools for manipulating, viewing, and early analysis of samples. The GeoLab was also designed for testing additional analytical instruments in a field setting.
Flow cytometric measurement of total DNA and incorporated halodeoxyuridine
Dolbeare, F.A.; Gray, J.W.
1983-10-18
A method for the simultaneous flow cylometric measurement of total cellular DNA content and of the uptake of DNA precursors as a measure of DNA synthesis during various phases of the cell cycle in normal and malignant cells in vitro and in vivo is described. The method comprises reacting cells with labelled halodeoxyuridine (HdU), partially denaturing cellular DNA, adding to the reaction medium monoclonal antibodies (mabs) reactive with HdU, reacting the bound mabs with a second labelled antibody, incubating the mixture with a DNA stain, and measuring simultaneously the intensity of the DNA stain as a measure of the total cellular DNA and the HdU incorporated as a measure of DNA synthesis. (ACR)
Demonstration of a Particle Impact Monitoring System for Crewed Space Exploration Modules
NASA Technical Reports Server (NTRS)
Opiela, J. N.; Liou, J.-C.; Corsaro, R.; Giovane, F.; Anz-Meador, P.
2011-01-01
When micrometeorite or debris impacts occur on a space habitat, crew members need to be quickly informed of the likely extent of damage, and be directed to the impact location for possible repairs. The goal of the Habitat Particle Impact Monitoring System (HIMS) is to develop a fully automated, end-to-end particle impact detection system for crewed space exploration modules, both in space and on the surfaces of Solar System bodies. The HIMS uses multiple thin film piezo-polymer vibration sensors to detect impacts on a surface, and computer processing of the acoustical signals to characterize the impacts. Development and demonstration of the HIMS is proceeding in concert with NASA's Habitat Demonstration Unit (HDU) Project. The HDU Project is designed to develop and test various technologies, configurations, and operational concepts for exploration habitats. This paper describes the HIMS development, initial testing, and HDU integration efforts. Initial tests of the system on the HDU were conducted at NASA?s 2010 Desert Research and Technologies Studies (Desert-RATS). Four sensor locations were assigned near the corners of a rectangular pattern. To study the influence of wall thickness, three sets of four sensors were installed at different layer depths: on the interior of the PEM wall, on the exterior of the same wall, and on the exterior of a layer of foam insulation applied to the exterior wall. Once the system was activated, particle impacts were periodically applied by firing a pneumatic pellet gun at the exterior wall section. Impact signals from the sensors were recognized by a data acquisition system when they occurred, and recorded on a computer for later analysis. Preliminary analysis of the results found that the HIMS system located the point of impact to within 8 cm, provided a measure of the impact energy / damage produced, and was insensitive to other acoustic events. Based on this success, a fully automated version of this system will be completed and demonstrated as part of a crew "Caution/Warning" system at the 2011 Desert-RATS, along with a crew response procedure.
NASA Technical Reports Server (NTRS)
Barsten, Kristina; Hurst, Victor, IV; Scheuring, Richard; Baumann, David K.; Johnson-Throop, Kathy
2010-01-01
Introduction: Analogue environments assist the NASA Human Research Program (HRP) in developing capabilities to mitigate high risk issues to crew health and performance for space exploration. The Habitat Demonstration Unit (HDU) is an analogue habitat used to assess space-related products for planetary missions. The Exploration Medical Capability (ExMC) element at the NASA Johnson Space Center (JSC) was tasked with developing planetary-relevant medical scenarios to evaluate the concept of operations for mitigating medical issues in such an environment. Methods: Two medical scenarios were conducted within the simulated planetary habitat with the crew executing two space flight-relevant procedures: Eye Examination with a corneal injury and Skin Laceration. Remote guidance for the crew was provided by a flight surgeon (FS) stationed at a console outside of the habitat. Audio and video data were collected to capture the communication between the crew and the FS, as well as the movements of the crew executing the procedures. Questionnaire data regarding procedure content and remote guidance performance also were collected from the crew immediately after the sessions. Results: Preliminary review of the audio, video, and questionnaire data from the two scenarios conducted within the HDU indicate that remote guidance techniques from an FS on console can help crew members within a planetary habitat mitigate planetary-relevant medical issues. The content and format of the procedures were considered concise and intuitive, respectively. Discussion: Overall, the preliminary data from the evaluation suggest that use of remote guidance techniques by a FS can help HDU crew execute space exploration-relevant medical procedures within a habitat relevant to planetary missions, however further evaluations will be needed to implement this strategy into the complete concept of operations for conducting general space medicine within similar environments
VizieR Online Data Catalog: Pulsation model data for delta Cep and eta Aql (Merand+, 2015)
NASA Astrophysics Data System (ADS)
Merand, A.; Kervella, P.; Breitfelder, J.; Gallenne, A.; Coude du Foresto, V.; ten Brummelaar, T. A.; McAlister, H. A.; Ridgway, S.; Sturmann, L.; Sturmann, J.; Turner, N. H.
2015-09-01
FITS files containing the stars' (delta Cep and eta Aql) data and model presented in the paper. Each fits file has 3 HDU: 1- primary HDU: contains no data apart from the header. The header has the parameters of the model (keywords 'HIERARCH PARAM') as well as some other quantities derived from the modeling (keywords 'HIERARCH MODEL'). These quantities are aimed at people who would like to reproduce or compare their results with us. 2- 'DATA' HDU: this contains the data used for the fit. Each line is a scalar measurement described as follow: col1='MJD' (E) modified Julian date of the observations col2='OBS' (A50) description of the data point: the string before ";" defines the type, after ";" is the source. after | are anciliary data: for diam, UDdiam: [wavelengthum, interfbaseline_m] for mag: photometric band for color: photometric band1 - photometric band2 col3='MEAS' (E) the actual measurements. units are km/s for Vpuls or Vrad (which includes the p-factor correction), and mas (milli-arcseconds) for diameters (diam of UDdiam). col4='ERR' (E) the uncertainty on the measurement. col5='MODEL' (E) corresponding value predicted by the model col6='PHASE' (E) pulsation phase computed from the model ranges from 0 to 1. col7='PERIOD' (E) pulsation period computed from the model in days 3- 'MODEL' HDU: a tabulation of the pulsation model, as a function of pulsation phase. col1='PHASE' (E) phase from 0 to 1. col2='Vpuls' (E) pulsation velocity, in km/s. col3='Vrad' (E) radial velocity, in km/s. It is Vpuls/p-factor + Vgamma. col4='diam' (E) Rosseland angular diameter, in milliarcseconds (mas). col5='Teff' (E) effective temperature, in Kelvin. col6='Lum' (E) Luminosity in solar luminosities. col7='logg' (E) surface gravity, in log_10(cm/s2). col8,9,10='diamK xxxm' (E) biased angular diameters measured by an interferometer at baselines xxx (in m), for xxx=[100, 200, 300]. In milliarcseconds col>=11= 'MAG ...' or 'COLOR ...' (E) reddenned magnitudes or colors in various bands, depending on the data entry. '...' is the name of band for magnitudes, and pair of bands for colors. (6 data files).
2009-12-01
forward-looking infrared FOV field-of-view HDU helmet display unit HMD helmet-mounted display IHADSS Integrated Helmet and Display...monocular Integrated Helmet and Display Sighting System (IHADSS) helmet-mounted display ( HMD ) in the British Army’s Apache AH Mk 1 attack helicopter has any...Integrated Helmet and Display Sighting System, IHADSS, Helmet-mounted display, HMD , Apache helicopter, Visual performance UNCLAS UNCLAS UNCLAS SAR 96
Desert Research and Technology Studies Exposure of Lotus Coated Electrodynamic Shield Samples
NASA Technical Reports Server (NTRS)
Rodriquez, Marcello; Peters, Wanda C.; Straka, Sharon A.; Jones, Craig B.
2011-01-01
The Lotus dust mitigation coating and the electrodynamic shield (EDS) are two new technologies currently being developed by NASA as countermeasures for addressing dust accumulation for long-duration human space exploration. These combined technologies were chosen by the Habitation Demonstration Unit (HDU) program for desert dust exposure at the Desert Research and Technologies Studies (D-RaTS) test site in Arizona. Characterization of these samples was performed prior to, during and post D-RaTS exposure.
T Tank Farm Interim Surface Barrier Demonstration - Vadose Zone Monitoring FY09 Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Z. F.; Strickland, Christopher E.; Field, Jim G.
2010-01-01
DOE’s Office of River Protection constructed a temporary surface barrier over a portion of the T Tank Farm as part of the T Farm Interim Surface Barrier Demonstration Project. As part of the demonstration effort, vadose zone moisture is being monitored to assess the effectiveness of the barrier at reducing soil moisture. A solar-powered system was installed to continuously monitor soil water conditions at four locations (i.e., instrument Nests A, B, C, and D) beneath the barrier and outside the barrier footprint as well as site meteorological conditions. Nest A is placed in the area outside the barrier footprint andmore » serves as a control, providing subsurface conditions outside the influence of the surface barrier. Nest B provides subsurface measurements to assess surface-barrier edge effects. Nests C and D are used to assess changes in soil-moisture conditions beneath the interim surface barrier. Each instrument nest is composed of a capacitance probe (CP) with multiple sensors, multiple heat-dissipation units (HDUs), and a neutron probe (NP) access tube. The monitoring results in FY09 are summarized below. The solar panels functioned normally and could provide sufficient power to the instruments. The CP in Nest C after September 20, 2009, was not functional. The CP sensors in Nest B after July 13 and the 0.9-m CP sensor in Nest D before June 10 gave noisy data. Other CPs were functional normally. All the HDUs were functional normally but some pressure-head values measured by HDUs were greater than the upper measurement-limit. The higher-than-upper-limit values might be due to the very wet soil condition and/or measurement error but do not imply the malfunction of the sensors. Similar to FY07 and FY08, in FY09, the soil under natural conditions (Nest A) was generally recharged during the winter period (October-March) and discharged during the summer period (April-September). Soil water conditions above about 1.5-m to 2-m depth from all three types of measurements (i.e., CP, NP and HDU) showed relatively large variation during the seasonal wetting-drying cycle. For the soil below 2-m depth, the seasonal variation of soil water content was relatively small. The construction of the surface barrier was completed in April 2008. In the soil below the surface barrier (Nests C and D), the CP measurements showed that water content at the soil between 0.6-m and 2.3-m depths was very stable, indicating no climatic impacts on soil water condition beneath the barrier. The NP-measured water content showed that soil water drainage seemed occurring in the soil between about 3.4 m (11 ft) and 9.1 m (30 ft) in FY09. The HDU-measured water pressure decreased consistently in the soil above 5-m depth, indicating soil water drainage at these depths of the soil. In the soil below the edge of the surface barrier (Nest B), the CP-measured water content was relatively stable through the year except at the 0.9-m depth; the NP-measured water content showed that soil water drainage was occurring in the soil between about 3.4 m (11 ft) and 9.1 m (30 ft) but at a slightly smaller magnitude than those in Nests C and D; the HDU-measurements show that the pressure head changes in FY09 in Nest B were less than those for C and D but more than those for A. The soil-water-pressure head was more sensitive to soil water regime changes under dry conditions. In the soil beneath the barrier, the theoretical steady-state values of pressure head is equal to the negative of the distance to groundwater table. Hence, it is expected that, in the future, while the water content become stable, the pressure head will keep decreasing for a long time (e.g., many years). These results indicate that the T Tank Farm surface barrier was performing as expected by intercepting the meteoric water from infiltrating into the soil and the soil was becoming drier gradually. The barrier also has some effects on the soil below the barrier edge but at a reduced magnitude.« less
Wood, Dora; Geoghegan, Sophie; Ramnarayan, Padmanabhan; Davis, Peter J; Pappachan, John V; Goodwin, Sarah; Wray, Jo
2018-05-01
Critically ill adolescents are usually treated on intensive care units optimised for much older adults or younger children. The way they access and experience health services may be very different to most adolescent service users, and existing quality criteria may not apply to them. The objectives of this pilot study were, firstly, to determine whether adolescents and their families were able to articulate their experiences of their critical care admission and secondly, to identify the factors that are important to them during their intensive care unit (ICU) or high dependency unit (HDU) stay. Participants were 14-17 year olds who had previously had an emergency admission to an adult or paediatric ICU/HDU in one of four UK hospitals (two adult, two paediatric) and their parents. Semi-structured interviews were conducted with eight mother-adolescent dyads and one mother. Interviews were transcribed and analysed using framework analysis. The main reported determinant of high-quality care was the quality of interaction with staff. The significance of these interactions and their environment depended on adolescents' awareness of their surroundings, which was often limited in ICU and changed significantly over the course of their illness. Qualitative interview methodology would be difficult to scale up for this group. What is known • Critically ill adolescents are usually treated on intensive care units optimised for older adults or younger children. • The way they access and experience health services may be different to most adolescent patients; existing quality criteria may not apply. What is new • Reported determinants of high-quality care were age-appropriateness of the environment, respectfulness and friendliness of staff, communication and inclusion in healthcare decisions. • The significance of these depended on adolescents' awareness of their surroundings, which was often limited and changed over the course of their illness.
Automated Operations Development for Advanced Exploration Systems
NASA Technical Reports Server (NTRS)
Haddock, Angie; Stetson, Howard K.
2012-01-01
Automated space operations command and control software development and its implementation must be an integral part of the vehicle design effort. The software design must encompass autonomous fault detection, isolation, recovery capabilities and also provide single button intelligent functions for the crew. Development, operations and safety approval experience with the Timeliner system on-board the International Space Station (ISS), which provided autonomous monitoring with response and single command functionality of payload systems, can be built upon for future automated operations as the ISS Payload effort was the first and only autonomous command and control system to be in continuous execution (6 years), 24 hours a day, 7 days a week within a crewed spacecraft environment. Utilizing proven capabilities from the ISS Higher Active Logic (HAL) System [1] , along with the execution component design from within the HAL 9000 Space Operating System [2] , this design paper will detail the initial HAL System software architecture and interfaces as applied to NASA s Habitat Demonstration Unit (HDU) in support of the Advanced Exploration Systems, Autonomous Mission Operations project. The development and implementation of integrated simulators within this development effort will also be detailed and is the first step in verifying the HAL 9000 Integrated Test-Bed Component [2] designs effectiveness. This design paper will conclude with a summary of the current development status and future development goals as it pertains to automated command and control for the HDU.
Automated Operations Development for Advanced Exploration Systems
NASA Technical Reports Server (NTRS)
Haddock, Angie T.; Stetson, Howard
2012-01-01
Automated space operations command and control software development and its implementation must be an integral part of the vehicle design effort. The software design must encompass autonomous fault detection, isolation, recovery capabilities and also provide "single button" intelligent functions for the crew. Development, operations and safety approval experience with the Timeliner system onboard the International Space Station (ISS), which provided autonomous monitoring with response and single command functionality of payload systems, can be built upon for future automated operations as the ISS Payload effort was the first and only autonomous command and control system to be in continuous execution (6 years), 24 hours a day, 7 days a week within a crewed spacecraft environment. Utilizing proven capabilities from the ISS Higher Active Logic (HAL) System, along with the execution component design from within the HAL 9000 Space Operating System, this design paper will detail the initial HAL System software architecture and interfaces as applied to NASA's Habitat Demonstration Unit (HDU) in support of the Advanced Exploration Systems, Autonomous Mission Operations project. The development and implementation of integrated simulators within this development effort will also be detailed and is the first step in verifying the HAL 9000 Integrated Test-Bed Component [2] designs effectiveness. This design paper will conclude with a summary of the current development status and future development goals as it pertains to automated command and control for the HDU.
Flow cytometric measurement of total DNA and incorporated halodeoxyuridine
Dolbeare, Frank A.; Gray, Joe W.
1988-01-01
A method for the simultaneous flow cytometric measurement of the total DNA content and the level of DNA synthesis in normal and malignant cells is disclosed. The sensitivity of the method allows a study of cell cycle traverse rates for large scale cell populations as well as single cell measurements. A DNA stain such as propidium iodide or Hoechst 33258 is used as the probe for the measurement of total DNA content and a monoclonal antibody reactive with a DNA precursor such as halodeoxy-uridine (HdU), more specifically bromodeoxyuridine (BrdU) is used as a probe for the measurement of HdU or BrdU uptake by the cells as a measure of DNA synthesis.
Castro-Avila, Ana Cristina; Serón, Pamela; Fan, Eddy; Gaete, Mónica; Mickan, Sharon
2015-01-01
Background and Aim Critically ill survivors may have functional impairments even five years after hospital discharge. To date there are four systematic reviews suggesting a beneficial impact for mobilisation in mechanically ventilated and intensive care unit (ICU) patients, however there is limited information about the influence of timing, frequency and duration of sessions. Earlier mobilisation during ICU stay may lead to greater benefits. This study aims to determine the effect of early rehabilitation for functional status in ICU/high-dependency unit (HDU) patients. Design Systematic review and meta-analysis. MEDLINE, EMBASE, CINALH, PEDro, Cochrane Library, AMED, ISI web of science, Scielo, LILACS and several clinical trial registries were searched for randomised and non-randomised clinical trials of rehabilitation compared to usual care in adult patients admitted to an ICU/HDU. Results were screened by two independent reviewers. Primary outcome was functional status. Secondary outcomes were walking ability, muscle strength, quality of life, and healthcare utilisation. Data extraction and methodological quality assessment using the PEDro scale was performed by primary reviewer and checked by two other reviewers. The authors of relevant studies were contacted to obtain missing data. Results 5733 records were screened. Seven articles were included in the narrative synthesis and six in the meta-analysis. Early rehabilitation had no significant effect on functional status, muscle strength, quality of life, or healthcare utilisation. However, early rehabilitation led to significantly more patients walking without assistance at hospital discharge (risk ratio 1.42; 95% CI 1.17-1.72). There was a non-significant effect favouring intervention for walking distance and incidence of ICU-acquired weakness. Conclusions Early rehabilitation during ICU stay was not associated with improvements in functional status, muscle strength, quality of life or healthcare utilisation outcomes, although it seems to improve walking ability compared to usual care. Results from ongoing studies may provide more data on the potential benefits of early rehabilitation in critically ill patients. PMID:26132803
VizieR Online Data Catalog: HD61005 SPHERE H and Ks images (Olofsson+, 2016)
NASA Astrophysics Data System (ADS)
Olofsson, J.; Samland, M.; Avenhaus, H.; Caceres, C.; Henning, T.; Moor, A.; Milli, J.; Canovas, H.; Quanz, S. P.; Schreiber, M. R.; Augereau, J.-C.; Bayo, A.; Bazzon, A.; Beuzit, J.-L.; Boccaletti, A.; Buenzli, E.; Casassus, S.; Chauvin, G.; Dominik, C.; Desidera, S.; Feldt, M.; Gratton, R.; Janson, M.; Lagrange, A.-M.; Langlois, M.; Lannier, J.; Maire, A.-L.; Mesa, D.; Pinte, C.; Rouan, D.; Salter, G.; Thalmann, C.; Vigan, A.
2016-05-01
The fits files contains the reduced ADI and DPI SPHERE observations used to produce Fig. 1 of the paper. Besides the primary card, the files consists of 6 additional ImageHDU. The first and second one contain the SPHERE IRDIS ADI H band observations and the noise map. The third and fourth contain the SPHERE IRDIS ADI Ks band observations and the corresponding noise map. Finally, the fifth and sixth ImageHDU contain the SPHERE IRDIS DPI H band data as well as the noise map. Each ADI image has 1024x1024 pixels, while the DPI images have 1800x1800 pixels. The header of the primary card contains the pixel sizes for each datasets and the wavelengths of the H and K band observations. (2 data files).
Augmented Reality Imaging System: 3D Viewing of a Breast Cancer.
Douglas, David B; Boone, John M; Petricoin, Emanuel; Liotta, Lance; Wilson, Eugene
2016-01-01
To display images of breast cancer from a dedicated breast CT using Depth 3-Dimensional (D3D) augmented reality. A case of breast cancer imaged using contrast-enhanced breast CT (Computed Tomography) was viewed with the augmented reality imaging, which uses a head display unit (HDU) and joystick control interface. The augmented reality system demonstrated 3D viewing of the breast mass with head position tracking, stereoscopic depth perception, focal point convergence and the use of a 3D cursor and joy-stick enabled fly through with visualization of the spiculations extending from the breast cancer. The augmented reality system provided 3D visualization of the breast cancer with depth perception and visualization of the mass's spiculations. The augmented reality system should be further researched to determine the utility in clinical practice.
Aiming for zero: decreasing central line associated bacteraemia in the intensive care unit.
Seddon, Mary E; Hocking, Catherine J; Mead, Pat; Simpson, Catherine
2011-07-29
To eliminate Central Line Associated Bacteraemia (CLAB) in the Critical Care Complex (CCC)-Intensive Care Unit (ICU) and High Dependency Unit (HDU)-Middlemore Hospital. Multifaceted quality improvement programme that included: engagement with ICU leadership and education of ICU staff; the introduction of a CLAB prevention bundle of care through standardised checklists for central line insertion (December 2008) and line maintenance (July 2009); the development of a central line pack; and rapid, visual feedback of results. Absolute numbers of CLAB in the CCC decreased from 14 in 2008, to 4 in 2009 and 1 in the first 6 months of 2010 (despite increase in bed census and a doubling of admissions). The CLAB rate per 1,000 line days decreased from 6.6 to 0.9. The days between CLAB increased from a median of 30 to >100 days, with zero CLAB for 5 of the last 6 months. Mortality for patients with CLAB was 37%, compared with mortality of 13% for all other ICU patients. The conservative cost savings were $200,000 in 2009 and $260,000 in 2010. Using an evidenced-based quality improvement approach, it is possible to significantly decrease Central Line Associated Bacteraemia in the Critical Care Complex. In doing so patient morbidity and mortality are reduced and money is saved for other healthcare needs.
Better prognostic marker in ICU - APACHE II, SOFA or SAP II!
Naqvi, Iftikhar Haider; Mahmood, Khalid; Ziaullaha, Syed; Kashif, Syed Mohammad; Sharif, Asim
2016-01-01
This study was designed to determine the comparative efficacy of different scoring system in assessing the prognosis of critically ill patients. This was a retrospective study conducted in medical intensive care unit (MICU) and high dependency unit (HDU) Medical Unit III, Civil Hospital, from April 2012 to August 2012. All patients over age 16 years old who have fulfilled the criteria for MICU admission were included. Predictive mortality of APACHE II, SAP II and SOFA were calculated. Calibration and discrimination were used for validity of each scoring model. A total of 96 patients with equal gender distribution were enrolled. The average APACHE II score in non-survivors (27.97+8.53) was higher than survivors (15.82+8.79) with statistically significant p value (<0.001). The average SOFA score in non-survivors (9.68+4.88) was higher than survivors (5.63+3.63) with statistically significant p value (<0.001). SAP II average score in non-survivors (53.71+19.05) was higher than survivors (30.18+16.24) with statistically significant p value (<0.001). All three tested scoring models (APACHE II, SAP II and SOFA) would be accurate enough for a general description of our ICU patients. APACHE II has showed better calibration and discrimination power than SAP II and SOFA.
Visual Performance of Contact Lens-Corrected Ametropic Aviators with the M-43 Protective Mask
1990-05-01
the HDU consists of a miniature cathode ray tube (CRT) located at the end of an optical relay tube attached to the side of the aviator’s helmet...14.6 =1441 Corneal thickness (mm) CL group_ Premask_ Postmask NCL group_ Premask Postmask (Subject O[_D OSj 1C D OS [Subject OID 0S_ _D OS 0001 .506
Boddington, N L; Verlander, N Q; Pebody, R G
2017-05-01
The UK Severe Influenza Surveillance System (USISS) was established following the 2009 influenza pandemic to monitor severe seasonal influenza. This article describes the severity of influenza observed in five post-2009 pandemic seasons in England. Two key measures were used to assess severity: impact measured through the cumulative incidence of laboratory-confirmed hospitalised influenza and case severity through the proportion of confirmed hospitalised cases admitted into intensive care units (ICU)/high dependency units (HDU). The impact of influenza varied by subtype and age group across the five seasons with the highest crude cumulative hospitalisation incidence for influenza A/H1N1pdm09 cases in 2010/2011 and in 0-4 year olds each season for all-subtypes. Case severity also varied by subtype and season with a higher hospitalisation: ICU ratio for A/H1N1pdm09 and older age groups (older than 45 years). The USISS system provides a tool for measuring severity of influenza each year. Such seasonal surveillance can provide robust baseline estimates to allow for rapid assessment of the severity of seasonal and emerging influenza viruses.
Fraser, Stephanie; Brady, Richard R; Graham, Catriona; Paterson-Brown, Simon; Gibb, Alan P
2010-01-01
INTRODUCTION Methicillin-resistant Staphylococcus aureus (MRSA)-related hospital-acquired infection (HAI) in surgical patients is associated with high morbidity, mortality and financial cost. The identification and characterisation of populations of patients who are at high risk of developing MRSA infection or colonisation could inform the design of more effective strategies to prevent HAIs and reduce transmission of MRSA. PATIENTS AND METHODS An analysis of historical discharge data for the whole of 2005 (7145 surgical in-patients) was performed, for all patients admitted to general surgery at the Royal Infirmary of Edinburgh. Analysis specifically focused on MRSA laboratory data and coding data for patient demographics, medical co-morbidities, and progress of in-patient stay. RESULTS A total of 134 (1.88%) individual patients with colonisation or infection by MRSA were identified from indicated laboratory testing. Univariate analysis identified a significant association of concurrent MRSA-positive status with patients aged over 60 years (P < 0.01), a duration of inpatient stay > 7 days (P < 0.01), presence of a malignant neoplasm (P < 0.01), circulatory disease (P < 0.01), respiratory disease (P < 0.01), central nervous system disease (P < 0.01), renal failure (P < 0.01), and concurrent admission to ITU/HDU (P < 0.01). Multivariate analysis suggested MRSA colonisation or infection was strongest in those with co-morbid malignancy (P < 0.0001) or admission to ITU/HDU (P < 0.0001). CONCLUSIONS This large observational study has identified cancer patients as a UK surgical patient subpopulation which is at significantly higher risk of colonisation by MRSA. These data could inform the development of focused hospital in-patient screening protocols and provide a means to stratify patient risk. PMID:20385046
Patient and staff satisfaction with 'day of admission' elective surgery.
Sofela, Agbolahan A; Laban, James T; Selway, Richard P
2013-04-01
To evaluate patient and staff satisfaction with day of admission surgery in a neurosurgical unit and its effect on theatre start times. Patients were admitted to a Neurosciences admission lounge (NAL) for neurosurgery on the morning of their operation if deemed appropriate by their neurosurgical consultant. All patients in the NAL were asked to complete patient satisfaction questionnaires. Staff members involved in the care of these patients also completed a satisfaction questionnaire. Theatre start times were compared with those whose patients had been admitted prior to the day of surgery. 378 patients admitted on the day of surgery, 16 doctors (5 anaesthetists, 7 neurosurgeons and 4 neuro high dependency unit, HDU doctors) and 5 nurses. Patients completed an anonymised emotional mapping patient satisfaction questionnaire, and short interviews were carried out with staff members. Theatre start times were obtained retrospectively from the theatre database for lists starting with patients admitted on the day of surgery, and lists starting with patients admitted prior to the day of surgery. 83% of patients felt positive on arrival in the NAL and 88% felt positive on being seen by the doctors and nurses prior to surgery. Overall 79% of patients gave positive responses throughout their patient pathway. 90% of staff were positive about day of admission surgery and all staff members were satisfied that there were no negative effects on surgical outcome. Theatre start time was on average 27 minutes earlier in patients admitted on the day of surgery. Neurosurgical patients, appropriately selected, can be admitted on the day of surgery with high staff and patient satisfaction and without delaying theatre start times.
NASA Technical Reports Server (NTRS)
Margiotta, Danielle V.; McKittrick, Kristin R.; Straka, Sharon A.; Jones, Craig B.
2012-01-01
The passive Lotus dust mitigation coating currently being developed at NASA's Goddard Space Flight Center (GSFC), was selected by the Habitation Demonstration Unit Deep Space Habitat (HDU-DSH) for participation in the 2011 Desert Research and Technology Studies (D-RaTS). Based on the unique surface architecture of the Lotus leaf, the nano-engineered Lotus coating seeks to replicate these structures on space flight and habitation surfaces. By decreasing both the surface energy and area for particle attachment, the Lotus coating greatly diminishes dust accumulation on surfaces. This is a problem that can be encountered on lunar, Martian, and asteroid missions. Two different application methods of this coating were tested in summer 2011 at the D-RaTS site: the wet chemistry applied version and combustion chemical vapor deposition (CCVD) applied version. These Lotus coatings, along with two common thermal control coatings, were combined with the active dust mitigation electrodynamic shield (EDS) technology developed at Kennedy Space Center (KSC). The EDS technology uses an electrified grid to remove dust particles from the surface of a Kapton (Trademark) substrate. The Lotus coating and thermal control coatings were applied to these Kapton (Trademark) substrates for testing. The combination of these two innovations was theorized to be an applicable countermeasure for addressing dust accumulation during long-duration human space exploration. This theory was tested and characterized prior to, during, and after D-RaTS exposure.
NASA Tech Briefs, January 2014
NASA Technical Reports Server (NTRS)
2014-01-01
Topics include: Multi-Source Autonomous Response for Targeting and Monitoring of Volcanic Activity; Software Suite to Support In-Flight Characterization of Remote Sensing Systems; Visual Image Sensor Organ Replacement; Ultra-Wideband, Dual-Polarized, Beam-Steering P-Band Array Antenna; Centering a DDR Strobe in the Middle of a Data Packet; Using a Commercial Ethernet PHY Device in a Radiation Environment; Submerged AUV Charging Station; Habitat Demonstration Unit (HDU) Vertical Cylinder Habitat; Origami-Inspired Folding of Thick, Rigid Panels; A Novel Protocol for Decoating and Permeabilizing Bacterial Spores for Epifluorescent Microscopy; Method and Apparatus for Automated Isolation of Nucleic Acids from Small Cell Samples; Enabling Microliquid Chromatography by Microbead Packing of Microchannels; On-Command Force and Torque Impeding Devices (OC-FTID) Using ERF; Deployable Fresnel Rings; Transition-Edge Hot-Electron Microbolometers for Millimeter and Submillimeter Astrophysics; Spacecraft Trajectory Analysis and Mission Planning Simulation (STAMPS) Software; Cross Support Transfer Service (CSTS) Framework Library; Arbitrary Shape Deformation in CFD Design; Range Safety Flight Elevation Limit Calculation Software; Frequency-Modulated, Continuous-Wave Laser Ranging Using Photon-Counting Detectors; Calculation of Operations Efficiency Factors for Mars Surface Missions; GPU Lossless Hyperspectral Data Compression System; Robust, Optimal Subsonic Airfoil Shapes; Protograph-Based Raptor-Like Codes; Fuzzy Neuron: Method and Hardware Realization; Kalman Filter Input Processor for Boresight Calibration; Organizing Compression of Hyperspectral Imagery to Allow Efficient Parallel Decompression; and Temperature Dependences of Mechanisms Responsible for the Water-Vapor Continuum Absorption.
Septic/unsafe abortion: a preventable tragedy.
Sultana, Ruqqia; Noor, Shehla; Fawwad, Ali; Abbasi, Nasreen; Bashir, Rubina
2012-01-01
Unsafe abortion is one of the greatest neglected problems of health care in developing countries like Pakistan. In countries where abortions are restricted women have to resort to clandestine interventions to have an unwanted pregnancy terminated. The study was conducted to find out the prevalence of septic induced abortion and the associated morbidity and mortality and to highlight the measures to reduce it. This cross-sectional descriptive study was carried out in Obs/Gyn B Unit, Ayub Teaching Hospital, Abbottabad from January 2007 to December 2011. During this period all the patients presenting with pyrexia lower abdominal pain, vaginal bleeding, acute abdomen, septic or hypovolaemic shock after undergoing some sort of intervention for abortion outside the hospital were included. After thorough history, examination and detailed investigations including high vaginal and endocervical swabs for culture and sensitivity and pelvic ultrasound supportive management was given followed by antibiotics, surgical evacuation of uterus/ major laparotomy in collaboration with surgeon as required. Patients with DIC or multiple system involvement were managed in High Dependency Unit (HDU) by multidisciplinary team. During the study period out of a total 6,906 admissions 968 presented with spontaneous abortion. There were 110 cases (11.36%) of unsafe abortion, 56.4% presented with vaginal discharge, 34.5% with vaginal bleeding, 21.8% with acute abdomen, while 18.9% in shock and 6.8% with DIC. Forty-nine percent patients used termination as a method of contraception. Mortality rate was 16.36%, leading cause being septicaemia. Death and severe morbidity from unsafe abortions and its complications is avoidable through health education, effective contraception, early informed recognition and management of the problem once it occurs.
Glasmacher, S A; Bonongwe, P; Stones, W
2016-03-01
To achieve good outcomes in critically ill obstetric patients, it is necessary to identify organ dysfunction rapidly so that life-saving interventions can be appropriately commenced. However, timely access to clinical chemistry results is problematic, even in referral institutions, in the sub-Saharan African region. Reliable point-of-care tests licensed for clinical use are now available for lactate and creatinine. We aimed to assess whether implementation of point-of-care testing for lactate and creatinine is feasible in the obstetric unit at the Queen Elizabeth Central Hospital (QECH) in Blantyre, Malawi, by obtaining the opinions of clinical staff on the use of these tests in practice. During a two-month evaluation period nurse-midwives, medical interns, clinical officers, registrars, and consultants were given the opportunity to use StatStrip® and StatSensor® (Nova Biomedical, Waltham, USA) devices, for lactate and creatinine estimation, as part of their routine clinical practice in the obstetric unit. They were subsequently asked to complete a short questionnaire. Thirty-seven questionnaires were returned by participants: 22 from nurse-midwives and the remainder from clinicians. The mean satisfaction score for the devices was 7.6/10 amongst clinicians and 8.0/10 amongst nurse-midwives. The majority of participants stated that the obstetric high dependency unit (HDU) was the most suitable location for the devices. For lactate, 31 participants strongly agreed that testing should be continued and 24 strongly agreed that it would influence patient management. For creatinine, 29 strongly agreed that testing should be continued and 28 strongly agreed that it would influence their patient management. Twenty participants strongly agreed that they trust point-of-care devices. Point-of-care clinical chemistry testing was feasible, practical, and well received by staff, and was considered to have a useful role to play in the clinical care of sick obstetric patients at this referral centre.
Christensen, Martin; Dodds, Andrew; Sauer, Josh; Watts, Nigel
2014-08-01
The aim of this survey was to assess registered nurse's perceptions of alarm setting and management in an Australian Regional Critical Care Unit. The setting and management of alarms within the critical care environment is one of the key responsibilities of the nurse in this area. However, with up to 99% of alarms potentially being false-positives it is easy for the nurse to become desensitised or fatigued by incessant alarms; in some cases up to 400 per patient per day. Inadvertently ignoring, silencing or disabling alarms can have deleterious implications for the patient and nurse. A total population sample of 48 nursing staff from a 13 bedded ICU/HDU/CCU within regional Australia were asked to participate. A 10 item open-ended and multiple choice questionnaire was distributed to determine their perceptions and attitudes of alarm setting and management within this clinical area. Two key themes were identified from the open-ended questions: attitudes towards inappropriate alarm settings and annoyance at delayed responses to alarms. A significant number of respondents (93%) agreed that alarm fatigue can result in alarm desensitisation and the disabling of alarms, whilst 81% suggested the key factors are those associated with false-positive alarms and inappropriately set alarms. This study contributes to what is known about alarm fatigue, setting and management within a critical care environment. In addition it gives an insight as to what nurses' within a regional context consider the key factors which contribute to alarm fatigue. Clearly nursing burnout and potential patient harm are important considerations for practice especially when confronted with alarm fatigue and desensitisation. Therefore, promoting and maintaining an environment of ongoing intra-professional communication and alarm surveillance are crucial in alleviating these potential problems. Copyright © 2014. Published by Elsevier Ltd.
Razmus, Ivy; Bergquist-Beringer, Sandra
2017-01-01
Little is known about pressure ulcer prevention practice among pediatric patients. To describe the frequency of pressure ulcer risk assessment in pediatric patients and pressure ulcer prevention intervention use overall and by hospital unit type, a descriptive secondary analysis was performed of data submitted to the National Database for Nursing Quality Indicators® (NDNQI®) for at least 3 of the 4 quarters in 2012. Relevant data on pressure ulcer risk from 271 hospitals across the United States extracted from the NDNQI database included patient skin and pressure ulcer risk assessment on admission, time since the last pressure ulcer risk assessment, method used to assess pressure ulcer risk, and risk status. Extracted data on pressure ulcer prevention included skin assessment, pressure-redistribution surface use, routine repositioning, nutritional support, and moisture management. These data were organized by unit type and merged with data on hospital characteristics for the analysis. The sample included 39 984 patients ages 1 day to 18 years on 678 pediatric acute care units (general pediatrics, pediatric critical care units, neonatal intensive care units, pediatric step-down units, and pediatric rehabilitation units). Descriptive statistics were used to analyze study data. Most of the pediatric patients (33 644; 89.2%) were assessed for pressure ulcer risk within 24 hours of admission. The Braden Q Scale was frequently used to assess risk on general pediatrics units (75.4%), pediatric step-down units (85.5%), pediatric critical care units (81.3%), and pediatric rehabilitation units (56.1%). In the neonatal intensive care units, another scale or method was used more often (55% to 60%) to assess pressure ulcer risk. Of the 11 203 pediatric patients (39%) determined to be at risk for pressure ulcers, the majority (10 741, 95.8%) received some kind of pressure ulcer prevention intervention during the 24 hours preceding the NDNQI pressure ulcer survey. The frequency of prevention intervention use among those at risk ranged from 99.2% for skin assessment to 70.7% for redistribution surface use. Most pediatric patients are being assessed for pressure ulcer risk, but the implementation of interventions to prevent pressure ulcers among children needs to be improved. Future qualitative research should be conducted to determine how and when clinical judgment is used to assess pressure ulcer risk and the type of pressure-redistribution surfaces used among younger pediatric patients.
Midwives' experiences of working in an obstetric high dependency unit: A qualitative study.
Eadie, Isabelle J; Sheridan, Nicolette F
2017-04-01
to understand the challenges experienced by midwives providing obstetric high dependency care and identify the training they perceive is needed for work in an obstetric high dependency unit. sixteen midwives who worked in the obstetric high dependency unit participated in one of three focus groups. Focus groups lasted 60-90minutes and were conducted in the workplace and facilitated by author (IE). Data were digitally recorded, transcribed and analysed manually by author (IE), specifically using a 'codebook' model to generate codes, categories and themes. a purpose built, two-bed obstetric high dependency unit located in the delivery suite of a large, urban tertiary teaching hospital in New Zealand. five themes were conceptualised: Theme 1: 'high dependency care is not our bread and butter'; the midwives felt that working in the obstetric high dependency work did not constitute 'normal' midwifery work. Theme 2: 'we are family… embracing the baby and partner in HDU'; the midwives recognised that an obstetric high dependency unit enabled the mother and infant to be cared for together, was beneficial for maternal psychosocial wellbeing, and supported mother-infant bonding and breastfeeding. Theme 3: 'primum non nocere; First, do no harm'; the midwives voiced concern that they lacked the skills and training to provide obstetric high dependency care and considered this a potential risk to sick women in their care. Theme 4: 'graceful swans and headless chickens'; the midwives reported feelings of stress, anxiety, fear and of being overwhelmed by the demands of obstetric high dependency care. The more experienced midwives were able to portray calmness and poise despite lots going on beneath the surface. This was in contrast to other, often less experienced midwives, who appeared confused and less organised. Theme 5: 'please sir, can I have some more training?'; the midwives unanimously sought training in the provision of obstetric high dependency care and saw facilitation of training to be a responsibility of the hospital. midwives who are competent in obstetric high dependency care are well placed to provide holistic care to sick women within an obstetric high dependency unit. Midwives found this work challenging and identified the need for specific knowledge and skills beyond those required in the provision of care to well women. The midwives sought post-registration training in obstetric high dependency care. These findings are consistent with other studies reported in the literature. post-registration training must be made available to midwives providing high dependency care to sick women to ensure they have the specialised skills and knowledge for practice. Responsibility to facilitate training rests with hospitals providing this service. Copyright © 2017 Elsevier Ltd. All rights reserved.
Cramer, Emily
2016-01-01
Abstract Hospital performance reports often include rankings of unit pressure ulcer rates. Differentiating among units on the basis of quality requires reliable measurement. Our objectives were to describe and apply methods for assessing reliability of hospital‐acquired pressure ulcer rates and evaluate a standard signal‐noise reliability measure as an indicator of precision of differentiation among units. Quarterly pressure ulcer data from 8,199 critical care, step‐down, medical, surgical, and medical‐surgical nursing units from 1,299 US hospitals were analyzed. Using beta‐binomial models, we estimated between‐unit variability (signal) and within‐unit variability (noise) in annual unit pressure ulcer rates. Signal‐noise reliability was computed as the ratio of between‐unit variability to the total of between‐ and within‐unit variability. To assess precision of differentiation among units based on ranked pressure ulcer rates, we simulated data to estimate the probabilities of a unit's observed pressure ulcer rate rank in a given sample falling within five and ten percentiles of its true rank, and the probabilities of units with ulcer rates in the highest quartile and highest decile being identified as such. We assessed the signal‐noise measure as an indicator of differentiation precision by computing its correlations with these probabilities. Pressure ulcer rates based on a single year of quarterly or weekly prevalence surveys were too susceptible to noise to allow for precise differentiation among units, and signal‐noise reliability was a poor indicator of precision of differentiation. To ensure precise differentiation on the basis of true differences, alternative methods of assessing reliability should be applied to measures purported to differentiate among providers or units based on quality. © 2016 The Authors. Research in Nursing & Health published by Wiley Periodicals, Inc. PMID:27223598
77 FR 8092 - Airworthiness Directives; Turbomeca S.A. Turboshaft Engines
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-14
...-pressure/low-pressure (HP/LP) pump hydro-mechanical metering units (HMUs) that do not incorporate... uncoupling of the high-pressure/low-pressure (HP/LP) pump hydro-mechanical metering unit (HMU) low-pressure...
Staggs, Vincent S; Cramer, Emily
2016-08-01
Hospital performance reports often include rankings of unit pressure ulcer rates. Differentiating among units on the basis of quality requires reliable measurement. Our objectives were to describe and apply methods for assessing reliability of hospital-acquired pressure ulcer rates and evaluate a standard signal-noise reliability measure as an indicator of precision of differentiation among units. Quarterly pressure ulcer data from 8,199 critical care, step-down, medical, surgical, and medical-surgical nursing units from 1,299 US hospitals were analyzed. Using beta-binomial models, we estimated between-unit variability (signal) and within-unit variability (noise) in annual unit pressure ulcer rates. Signal-noise reliability was computed as the ratio of between-unit variability to the total of between- and within-unit variability. To assess precision of differentiation among units based on ranked pressure ulcer rates, we simulated data to estimate the probabilities of a unit's observed pressure ulcer rate rank in a given sample falling within five and ten percentiles of its true rank, and the probabilities of units with ulcer rates in the highest quartile and highest decile being identified as such. We assessed the signal-noise measure as an indicator of differentiation precision by computing its correlations with these probabilities. Pressure ulcer rates based on a single year of quarterly or weekly prevalence surveys were too susceptible to noise to allow for precise differentiation among units, and signal-noise reliability was a poor indicator of precision of differentiation. To ensure precise differentiation on the basis of true differences, alternative methods of assessing reliability should be applied to measures purported to differentiate among providers or units based on quality. © 2016 The Authors. Research in Nursing & Health published by Wiley Periodicals, Inc. © 2016 The Authors. Research in Nursing & Health published by Wiley Periodicals, Inc.
Polignano, Francesco M; Quyn, Aaron J; de Figueiredo, Rodrigo S M; Henderson, Nikola A; Kulli, Christoph; Tait, Iain S
2008-12-01
Reduction in hospital stay, blood loss, postoperative pain and complications are common findings after laparoscopic liver resection, suggesting that the laparoscopic approach may be a suitable alternative to open surgery. Some concerns have been raised regarding cost effectiveness of this procedure and potential implications of its large-scale application. Our aim has been to determine cost effectiveness of laparoscopic liver surgery by a case-matched, case-control, intention-to-treat analysis of its costs and short-term clinical outcomes compared with open surgery. Laparoscopic liver segmentectomies and bisegmentectomies performed at Ninewells Hospital and Medical School between 2005 and 2007 were considered. Resections involving more than two Couinaud segments, or involving any synchronous procedure, were excluded. An operation-magnitude-matched control group was identified amongst open liver resections performed between 2004 and 2007. Hospital costs were obtained from the Scottish Health Service Costs Book (ISD Scotland) and average national costs were calculated. Cost of theatre time, disposable surgical devices, hospital stay, and high-dependency unit (HDU) and intensive care unit (ICU) usage were the main endpoints for comparison. Secondary endpoints were morbidity and mortality. Statistical analysis was performed with Student's t-test, chi(2) and Fisher exact test as most appropriate. Twenty-five laparoscopic liver resections were considered, including atypical resection, segmentectomy and bisegmentectomy, and they were compared to 25 matching open resections. The two groups were homogeneous by age, sex, coexistent morbidity, magnitude of resection, prevalence of liver cirrhosis and indications. Operative time (p < 0.03), blood loss (p < 0.0001), Pringle manoeuvre (p < 0.03), hospital stay (p < 0.003) and postoperative complications (p < 0.002) were significantly reduced in the laparoscopic group. Overall hospital cost was significantly lower in the laparoscopic group by an average of 2,571 pounds sterling (p < 0.04). Laparoscopic liver segmentectomy and bisegmentectomy are feasible, safe and cost effective compared to similar open resections. Large-scale application of laparoscopic liver surgery could translate into significant savings to hospitals and health care programmes.
Brunelli, Alessandro; Tentzeris, Vasileios; Sandri, Alberto; McKenna, Alexandra; Liew, Shan Liung; Milton, Richard; Chaudhuri, Nilanjan; Kefaloyannis, Emmanuel; Papagiannopoulos, Kostas
2016-05-01
To develop a clinically risk-adjusted financial model to estimate the cost associated with a video-assisted thoracoscopic surgery (VATS) lobectomy programme. Prospectively collected data of 236 VATS lobectomy patients (August 2012-December 2013) were analysed retrospectively. Fixed and variable intraoperative and postoperative costs were retrieved from the Hospital Accounting Department. Baseline and surgical variables were tested for a possible association with total cost using a multivariable linear regression and bootstrap analyses. Costs were calculated in GBP and expressed in Euros (EUR:GBP exchange rate 1.4). The average total cost of a VATS lobectomy was €11 368 (range €6992-€62 535). Average intraoperative (including surgical and anaesthetic time, overhead, disposable materials) and postoperative costs [including ward stay, high dependency unit (HDU) or intensive care unit (ICU) and variable costs associated with management of complications] were €8226 (range €5656-€13 296) and €3029 (range €529-€51 970), respectively. The following variables remained reliably associated with total costs after linear regression analysis and bootstrap: carbon monoxide lung diffusion capacity (DLCO) <60% predicted value (P = 0.02, bootstrap 63%) and chronic obstructive pulmonary disease (COPD; P = 0.035, bootstrap 57%). The following model was developed to estimate the total costs: 10 523 + 1894 × COPD + 2376 × DLCO < 60%. The comparison between predicted and observed costs was repeated in 1000 bootstrapped samples to verify the stability of the model. The two values were not different (P > 0.05) in 86% of the samples. A hypothetical patient with COPD and DLCO less than 60% would cost €4270 more than a patient without COPD and with higher DLCO values (€14 793 vs €10 523). Risk-adjusting financial data can help estimate the total cost associated with VATS lobectomy based on clinical factors. This model can be used to audit the internal financial performance of a VATS lobectomy programme for budgeting, planning and for appropriate bundled payment reimbursements. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
A prospective audit of a nurse independent prescribing within critical care.
Carberry, Martin; Connelly, Sarah; Murphy, Jennifer
2013-05-01
To determine the prescribing activity of different staff groups within intensive care unit (ICU) and combined high dependency unit (HDU), namely trainee and consultant medical staff and advanced nurse practitioners in critical care (ANPCC); to determine the number and type of prescription errors; to compare error rates between prescribing groups and to raise awareness of prescribing activity within critical care. The introduction of government legislation has led to the development of non-medical prescribing roles in acute care. This has facilitated an opportunity for the ANPCC working in critical care to develop a prescribing role. The audit was performed over 7 days (Monday-Sunday), on rolling days over a 7-week period in September and October 2011 in three ICUs. All drug entries made on the ICU prescription by the three groups, trainee medical staff, ANPCCs and consultant anaesthetists, were audited once for errors. Data were collected by reviewing all drug entries for errors namely, patient data, drug dose, concentration, rate and frequency, legibility and prescriber signature. A paper data collection tool was used initially; data was later entered onto a Microsoft Access data base. A total of 1418 drug entries were audited from 77 patient prescription Cardexes. Error rates were reported as, 40 errors in 1418 prescriptions (2·8%): ANPCC errors, n = 2 in 388 prescriptions (0·6%); trainee medical staff errors, n = 33 in 984 (3·4%); consultant errors, n = 5 in 73 (6·8%). The error rates were significantly different for different prescribing groups (p < 0·01). This audit shows that prescribing error rates were low (2·8%). Having the lowest error rate, the nurse practitioners are at least as effective as other prescribing groups within this audit, in terms of errors only, in prescribing diligence. National data is required in order to benchmark independent nurse prescribing practice in critical care. These findings could be used to inform research and role development within the critical care. © 2012 The Authors. Nursing in Critical Care © 2012 British Association of Critical Care Nurses.
Portable Dynamic Pressure Calibrator
NASA Technical Reports Server (NTRS)
Wright, Morgan S.; Maynard, Everett (Technical Monitor)
1996-01-01
A portable, dynamic pressure calibrator was fabricated for use on wind tunnel models at NASA-Ames Research Center. The calibrator generates sine wave pressures at levels up to 1 PSIG P-P(168dB) at frequencies from 10Hz to 6KHz and .5 PSIG P.P (162dB) at frequencies from 6KHz to 20KHz. The calibrator consists of two units connected by a single cable. The handheld unit contains a pressure transducer, speaker, and deadman switch. This unit allows application of dynamic pressure to transducers/ports on installed wind tunnel models. The base unit contains all of power supplies, controls and displays. This unit allows amplitude and frequency to be set and verified at a safe location off of the model.
Sjödin, Carl; Sondergaard, Soren; Johansson, Lotta
2018-06-01
The phlebostatic axis is the most commonly used anatomical external reference point for central venous pressure measurements. Deviation in the central venous pressure transducer alignment from the phlebostatic axis causes inadequate pressure readings, which may affect treatment decisions for critically ill patients in intensive care units. The primary aim of the study was to assess the variability in central venous pressure transducer levelling in the intensive care unit. We also assessed whether patient characteristics impacted on central venous pressure transducer alignment deviation. A sample of 61 critical care nurses was recruited and asked to place a transducer at the appropriate level for central venous pressure measurement. The measurements were performed in the intensive care unit on critically ill patients in supine and Fowler's positions. The variability among the participants using eyeball levelling and a laser levelling device was calculated in both sessions and adjusted for patient characteristics. A significant variation was found among critical care nurses in the horizontal levelling of the pressure transducer placement when measuring central venous pressure in the intensive care unit. Using a laser levelling device did not reduce the deviation from the phlebostatic axis. Patient characteristics had little impact on the deviation in the measurements. The anatomical external landmark for the phlebostatic axis varied between critical care nurses, as the variation in the central venous pressure transducer placement was not reduced with a laser levelling device. Standardisation of a zero-level for vascular pressures should be considered to reduce the variability in vascular pressure readings in the intensive care unit to improve patient treatment decisions. Further studies are needed to evaluate critical care nurses' knowledge and use of central venous pressure monitoring and whether assistive tools and/or routines can improve the accuracy in vascular pressure measurements in intensive care units. Copyright © 2018 Australian College of Critical Care Nurses Ltd. Published by Elsevier Ltd. All rights reserved.
Measuring Time-Averaged Blood Pressure
NASA Technical Reports Server (NTRS)
Rothman, Neil S.
1988-01-01
Device measures time-averaged component of absolute blood pressure in artery. Includes compliant cuff around artery and external monitoring unit. Ceramic construction in monitoring unit suppresses ebb and flow of pressure-transmitting fluid in sensor chamber. Transducer measures only static component of blood pressure.
An Electronic Pressure Profile Display system for aeronautic test facilities
NASA Technical Reports Server (NTRS)
Woike, Mark R.
1990-01-01
The NASA Lewis Research Center has installed an Electronic Pressure Profile Display system. This system provides for the real-time display of pressure readings on high resolution graphics monitors. The Electronic Pressure Profile Display system will replace manometer banks currently used in aeronautic test facilities. The Electronic Pressure Profile Display system consists of an industrial type Digital Pressure Transmitter (DPI) unit which interfaces with a host computer. The host computer collects the pressure data from the DPI unit, converts it into engineering units, and displays the readings on a high resolution graphics monitor in bar graph format. Software was developed to accomplish the above tasks and also draw facility diagrams as background information on the displays. Data transfer between host computer and DPT unit is done with serial communications. Up to 64 channels are displayed with one second update time. This paper describes the system configuration, its features, and its advantages over existing systems.
An electronic pressure profile display system for aeronautic test facilities
NASA Technical Reports Server (NTRS)
Woike, Mark R.
1990-01-01
The NASA Lewis Research Center has installed an Electronic Pressure Profile Display system. This system provides for the real-time display of pressure readings on high resolution graphics monitors. The Electronic Pressure Profile Display system will replace manometer banks currently used in aeronautic test facilities. The Electronic Pressure Profile Display system consists of an industrial type Digital Pressure Transmitter (DPT) unit which interfaces with a host computer. The host computer collects the pressure data from the DPT unit, converts it into engineering units, and displays the readings on a high resolution graphics monitor in bar graph format. Software was developed to accomplish the above tasks and also draw facility diagrams as background information on the displays. Data transfer between host computer and DPT unit is done with serial communications. Up to 64 channels are displayed with one second update time. This paper describes the system configuration, its features, and its advantages over existing systems.
A wireless blood pressure monitoring system for personal health management.
Li, Wun-Jin; Luo, Yuan-Long; Chang, Yao-Shun; Lin, Yuan-Hsiang
2010-01-01
In this paper, we developed a wireless blood pressure monitoring system which provides a useful tool for users to measure and manage their daily blood pressure values. This system includes an ARM-based blood pressure monitor with a ZigBee wireless transmission module and a PC-based management unit with graphic user interface and database. The wireless blood pressure monitor can measure the blood pressure and heart rate and then store and forward the measuring information to the management unit through the ZigBee wireless transmission. On the management unit, user can easy to see their blood pressure variation in the past using a line chart. Accuracy of blood pressure measurement has been verified by a commercial blood pressure simulator and shown the bias of systolic blood pressure is ≤ 1 mmHg and the bias of diastolic blood pressure is ≤ 1.4 mmHg.
1975-01-29
will shut down automatically when condenser high pressure causes Pressure Limit Control high pressure switch to release. Press START switch (3...power cable (1) from facility pow- er. Troubleshoot cooling unit, for HI-LOW pressure switch repeated cutout. Refer to AGE ECU Cooling Unit...acti- vate when loss of air flow oc- curred, the pressure switch (3) failed to open circuit. Adjust or replace pressure switch . Refer to
Boyle, Diane K; Jayawardhana, Ananda; Burman, Mary E; Dunton, Nancy E; Staggs, Vincent S; Bergquist-Beringer, Sandra; Gajewski, Byron J
2016-11-01
Composite indices are single measures that combine the strengths of two or more individual measures and provide broader, easy-to-use measures for evaluation of provider performance and comparisons across units and hospitals to support quality improvement. The study objective was to develop a unit-level inpatient composite nursing care quality performance index-the Pressure Ulcer and Fall Rate Quality Composite Index. Two-phase measure development study. 5144 patient care units in 857 United States hospitals participating in the National Database of Nursing Quality Indictors ® during the year 2013. The Pressure Ulcer and Fall Rate Quality Composite Index was developed in two phases. In Phase 1 the formula was generated using a utility function and generalized penalty analysis. Experts with experience in healthcare quality measurement provided the point of indicator equivalence. In Phase 2 initial validity evidence was gathered based on hypothesized relationships between the Pressure Ulcer and Fall Rate Quality Composite Index and other variables using two-level (unit, hospital) hierarchical linear mixed modeling. The Pressure Ulcer and Fall Rate Quality Composite Index=100-PUR-FR, where PUR is pressure ulcer rate and FR is total fall rate. Higher scores indicate better quality. Bland-Altman plots demonstrated agreement between pairs of experts and provided evidence for inter-rater reliability of the formula. The validation process demonstrated that higher registered nurse skill mix, higher percent of registered nurses with a baccalaureate in nursing or higher degree, higher percent of registered nurses with national specialty certification, and lower percent of hours supplied by agency staff were significantly associated with higher Pressure Ulcer and Fall Rate Quality Composite Index scores. Higher percentages of unit patients at risk for a hospital-acquired pressure ulcer and higher unit rates of physical restraint use were not associated with higher Pressure Ulcer and Fall Rate Quality Composite Index scores. The Pressure Ulcer and Fall Rate Quality Composite Index is a step toward providing a more holistic perspective of unit level nursing quality than individual measures and may help nurses nursing administrators obtain a broader view of which patient care units are the higher and lower performers. Further study is needed to examine the usability of the Pressure Ulcer and Fall Rate Quality Composite Index. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Jayawardhana, Ananda; Burman, Mary E.; Dunton, Nancy E.; Staggs, Vincent S.; Bergquist-Beringer, Sandra; Gajewski, Byron J.
2016-01-01
Background Composite indices are single measures that combine the strengths of two or more individual measures and provide broader, easy-to-use measures for evaluation of provider performance and comparisons across units and hospitals to support quality improvement. Objective The study objective was to develop a unit-level inpatient composite nursing care quality performance index – the Pressure Ulcer and Fall Rate Quality Composite Index. Design Two-phase measure development study. Settings 5,144 patient care units in 857 United States hospitals participating in the National Database of Nursing Quality Indictors® during the year 2013. Methods The Pressure Ulcer and Fall Rate Quality Composite Index was developed in two phases. In Phase 1 the formula was generated using a utility function and generalized penalty analysis. Experts with experience in healthcare quality measurement provided the point of indicator equivalence. In Phase 2 initial validity evidence was gathered based on hypothesized relationships between the Pressure Ulcer and Fall Rate Quality Composite Index and other variables using two-level (unit, hospital) hierarchical linear mixed modeling. Results The Pressure Ulcer and Fall Rate Quality Composite Index = 100 − PUR − FR, where PUR is pressure ulcer rate and FR is total fall rate. Higher scores indicate better quality. Bland-Altman plots demonstrated agreement between pairs of experts and provided evidence for inter-rater reliability of the formula. The validation process demonstrated that higher registered nurse skill mix, higher percent of registered nurses with a baccalaureate in nursing or higher degree, higher percent of registered nurses with national specialty certification, and lower percent of hours supplied by agency staff were significantly associated with higher Pressure Ulcer and Fall Rate Quality Composite Index scores. Higher percentages of unit patients at risk for a hospital-acquired pressure ulcer and higher unit rates of physical restraint use were not associated with higher Pressure Ulcer and Fall Rate Quality Composite Index scores. Conclusions The Pressure Ulcer and Fall Rate Quality Composite Index is a step toward providing a more holistic perspective of unit level nursing quality than individual measures and may help nurses nursing administrators obtain a broader view of which patient care units are the higher and lower performers. Further study is needed to examine the usability of the Pressure Ulcer and Fall Rate Quality Composite Index. PMID:27607602
[Pressure sores unit--a one year study].
Jaul, E
2001-10-01
The phenomenon of pressure sores in the elderly patient often requires an alternative management policy to that of the standard treatment. In general, the therapeutic approach to pressure sores in the elderly should be different to that in younger patients. This modification is due to the accompanying comorbidity so often associated with aging. Due to accompanying illnesses, the aging population is at high risk and more predisposed to the development of pressure sores. The importance of the establishment of a unit for pressure sores arises from the specific geriatric team approach to the patient and the need to focus carefully on the pressure sores. The management of this special Pressure Sores Unit with a permanent capable staff requires skilled treatment, both localized and systemic, since pressure sores are very often a result of systemic failure or an indication of a terminal condition in the elderly patient. Over six months we followed-up on the number and location of the pressure sores in 47 patients in addition to other functional and nutritional parameters, in order to investigate any connection between the pressure sores and nutritional parameters. The results of the study indicate that the nutritional state of the patients admitted for pressure sores was very poor. Two thirds of the patients suffered from either dementia or stroke, and 90 percent were bedridden, incontinent and enterally fed. Despite the poor general condition of the patient, the study shows improvement in the pressure sores with a reduction from an average of 2.8 to 1.8 pressure sores per patient. The improvement in the pressure sore located on the legs was three times greater than those located in the pelvic area. By the end of the study, 50% of the patients had died, 33% of the original patients who were still in the unit showed improvement in the pressure sores and 15% were discharged showing complete recovery from the sores. No significant correlation was found between changes in the pressure sores and the parameters relating to nutritional status (albumin, cholesterol, body weight and total lymphocyte count) except for the level of hemoglobin. Since there was no control group, the results of the study, naturally, did not show any advantage in treatment of pressure sores in a specific unit as opposed to such treatment in a general ward. Nevertheless, the need for a Pressure Sores Unit is justified and important. It is possible that the patients observed in this study arrived for treatment in the unit at very late, irreversible and terminal stages. The presence of a Pressure Sores Unit would heighten awareness and early referral of these patients.
Park, Shin Hye; Boyle, Diane K; Bergquist-Beringer, Sandra; Staggs, Vincent S; Dunton, Nancy E
2014-08-01
We examined the concurrent and lagged effects of registered nurse (RN) turnover on unit-acquired pressure ulcer rates and whether RN staffing mediated the effects. Quarterly unit-level data were obtained from the National Database of Nursing Quality Indicators for 2008 to 2010. A total of 10,935 unit-quarter observations (2,294 units, 465 hospitals) were analyzed. This longitudinal study used multilevel regressions and tested time-lagged effects of study variables on outcomes. The lagged effect of RN turnover on unit-acquired pressure ulcers was significant, while there was no concurrent effect. For every 10 percentage-point increase in RN turnover in a quarter, the odds of a patient having a pressure ulcer increased by 4 percent in the next quarter. Higher RN turnover in a quarter was associated with lower RN staffing in the current and subsequent quarters. Higher RN staffing was associated with lower pressure ulcer rates, but it did not mediate the relationship between turnover and pressure ulcers. We suggest that RN turnover is an important factor that affects pressure ulcer rates and RN staffing needed for high-quality patient care. Given the high RN turnover rates, hospital and nursing administrators should prepare for its negative effect on patient outcomes. © Health Research and Educational Trust.
Park, Shin Hye; Boyle, Diane K; Bergquist-Beringer, Sandra; Staggs, Vincent S; Dunton, Nancy E
2014-01-01
Objective We examined the concurrent and lagged effects of registered nurse (RN) turnover on unit-acquired pressure ulcer rates and whether RN staffing mediated the effects. Data Sources/Setting Quarterly unit-level data were obtained from the National Database of Nursing Quality Indicators for 2008 to 2010. A total of 10,935 unit-quarter observations (2,294 units, 465 hospitals) were analyzed. Methods This longitudinal study used multilevel regressions and tested time-lagged effects of study variables on outcomes. Findings The lagged effect of RN turnover on unit-acquired pressure ulcers was significant, while there was no concurrent effect. For every 10 percentage-point increase in RN turnover in a quarter, the odds of a patient having a pressure ulcer increased by 4 percent in the next quarter. Higher RN turnover in a quarter was associated with lower RN staffing in the current and subsequent quarters. Higher RN staffing was associated with lower pressure ulcer rates, but it did not mediate the relationship between turnover and pressure ulcers. Conclusions We suggest that RN turnover is an important factor that affects pressure ulcer rates and RN staffing needed for high-quality patient care. Given the high RN turnover rates, hospital and nursing administrators should prepare for its negative effect on patient outcomes. PMID:24476194
Flat Surface Damage Detection System (FSDDS)
NASA Technical Reports Server (NTRS)
Williams, Martha; Lewis, Mark; Gibson, Tracy; Lane, John; Medelius, Pedro; Snyder, Sarah; Ciarlariello, Dan; Parks, Steve; Carrejo, Danny; Rojdev, Kristina
2013-01-01
The Flat Surface Damage Detection system (FSDDS} is a sensory system that is capable of detecting impact damages to surfaces utilizing a novel sensor system. This system will provide the ability to monitor the integrity of an inflatable habitat during in situ system health monitoring. The system consists of three main custom designed subsystems: the multi-layer sensing panel, the embedded monitoring system, and the graphical user interface (GUI). The GUI LABVIEW software uses a custom developed damage detection algorithm to determine the damage location based on the sequence of broken sensing lines. It estimates the damage size, the maximum depth, and plots the damage location on a graph. Successfully demonstrated as a stand alone technology during 2011 D-RATS. Software modification also allowed for communication with HDU avionics crew display which was demonstrated remotely (KSC to JSC} during 2012 integration testing. Integrated FSDDS system and stand alone multi-panel systems were demonstrated remotely and at JSC, Mission Operations Test using Space Network Research Federation (SNRF} network in 2012. FY13, FSDDS multi-panel integration with JSC and SNRF network Technology can allow for integration with other complementary damage detection systems.
Improved monoclonal antibodies to halodeoxyuridine
Vanderlaan, M.; Dolbeare, F.A.; Gray, J.W.; Thomas, C.B.
1983-10-18
The development, method of production, characterization and methods of use of two hybridomas, CIdU-1 (ATCC Accession No. HB-8321) and CIdU-2 (ATCC Accession No. HB-8320), are described. These secrete IgG/sub 1/(K) immunoglobulins that react with halodeoxyuridine (HdU or halodU) such as bromo, chloro, fluoro and iodo deoxyuridine (BrdU, CldU, FdU and IdU), whether these are free in solution or incorporated into single stranded DNA in whole cells. The antibodies do not react with naturally occurring free nucleic acids or with deoxyribonucleic acid (DNA) or ribonucleic acid (RNA) polymers. These antibodies are suitable for use in enzyme immunoassays for free CldU, FdU, IdU and BrdU and for detecting cells with these nucleotides incorporated into them. The monoclonal antibodies are useful in the detection of the sensitivity of tumor cells to specific chemotherapeutic agents, in the measurement of the rate of cellular DNA synthesis, in the measurement of the rate of proliferation of normal and malignant cells and in the detection of HPRT deficiency in cells. 1 tab.
NASA Astrophysics Data System (ADS)
Pleuger, Jan; Podladchikov, Yuri
2014-05-01
The Penninic Alps are the result of progressive underthrusting of oceanic and continental domains below the Adriatic microplate. Situated in the internal part of the Alpine orogen, they expose basement and thinned cover nappes which have been metamorphosed to variable degree, among them several units which were subjected to ultrahigh-pressure metamorphism. Due to the more or less strong nappe-internal deformation of these units, cross sections through the Penninic Alps cannot be restored kinematically by area or line balancing techniques. Instead, such restorations attempt to consistently reconcile geochronological and structural data and petrological pressure-temperature estimates. Pressure data are usually converted into depth assuming that they were lithostatic which puts the ultrahigh-pressure units to subcrustal depths. Tectonic exhumation of a unit from such a depth by whatever mechanism requires a large-scale normal fault with several tens of kilometres of displacement in the hanging wall of the unit. However, for all Penninic ultrahigh-pressure units (Dora Maira unit, Zermatt-Saas zone, Monviso unit, Adula-Cima Lunga nappe), the oldest mappable post-peak-pressure structures are related to top-to-the-foreland shearing, i.e. thrusting. There are two potential solutions to this dilemma. The first one is that either the exhumation was indeed accommodated by a large-scale normal fault which became completely overprinted during later deformational stages. The other one is that peak pressures were not lithostatic. To our knowledge, the first solution is applied to all kinematic models of the Alps so far. In order to explore the feasibility of the second solution, we performed a purely structural restoration of the NFP20-East cross section without lithostatic pressure-to-depth-conversions. This cross-section comprises the ultrahigh-pressure Adula nappe (up to ca. 30 kbar) and relies on quantitative strain data from the overlying units. The result shows that, in accordance with the structural record, the Adula nappe can be restored to maximum depths of up to ca. 60 km. For individual points of the Adula nappe in the restored cross section, corresponding to the sporadic occurences of (ultra)high-pressure rocks, lithostatic pressures are exceeded by petrological peak-pressure data by about 40% to 80%. Such amounts of tectonic overpressure are within the limits of theoretical considerations and numerical modelling results. For the other units comprised in the cross section, and for subsequent tectono-metamorphic stages of the Adula nappe, negligible amounts of overpressure (around 10%) are determined from the restoration. We conclude that (1) the NFP20-East cross section can be kinematically restored by using only structural data, (2) the dilemma mentioned above can be solved by admitting realisting amounts of tectonic overpressure, and (3) significant amounts of overpressure were established only locally and episodically.
Factors affecting plant growth in membrane nutrient delivery
NASA Technical Reports Server (NTRS)
Dreschel, T. W.; Wheeler, R. M.; Sager, J. C.; Knott, W. M.
1990-01-01
The development of the tubular membrane plant growth unit for the delivery of water and nutrients to roots in microgravity has recently focused on measuring the effects of changes in physical variables controlling solution availability to the plants. Significant effects of membrane pore size and the negative pressure used to contain the solution were demonstrated. Generally, wheat grew better in units with a larger pore size but equal negative pressure and in units with the same pore size but less negative pressure. Lettuce also exhibited better plant growth at less negative pressure.
NASA Technical Reports Server (NTRS)
Helms, C. R.; Smyly, H. M. (Inventor)
1981-01-01
A pump/valve unit for controlling the inflation and deflation of a urethral collar in a prosthetic urinary sphincter device is described. A compressible bulb pump defining a reservoir was integrated with a valve unit for implantation. The valve unit includes a movable valve member operable by depression of a flexible portion of the valve unit housing for controlling fluid flow between the reservoir and collar; and a pressure sensing means which operates the valve member to relieve an excess pressure in the collar should too much pressure be applied by the patient.
Pressure vessel sliding support unit and system using the sliding support unit
Breach, Michael R.; Keck, David J.; Deaver, Gerald A.
2013-01-15
Provided is a sliding support and a system using the sliding support unit. The sliding support unit may include a fulcrum capture configured to attach to a support flange, a fulcrum support configured to attach to the fulcrum capture, and a baseplate block configured to support the fulcrum support. The system using the sliding support unit may include a pressure vessel, a pedestal bracket, and a plurality of sliding support units.
Li, Dan
2016-08-01
To explore the quality/comprehensiveness of nursing documentation of pressure ulcers and to investigate the relationship between the nursing documentation and the incidence of pressure ulcers in four intensive care units. Pressure ulcer prevention requires consistent assessments and documentation to decrease pressure ulcer incidence. Currently, most research is focused on devices to prevent pressure ulcers. Studies have rarely considered the relationship among pressure ulcer risk factors, incidence and nursing documentation. Thus, a study to investigate this relationship is needed to fill this information gap. A retrospective, comparative, descriptive, correlational study. A convenience sample of 196 intensive care units patients at the selected medical centre comprised the study sample. All medical records of patients admitted to intensive care units between the time periods of September 1, 2011 through September 30, 2012 were audited. Data used in the analysis included 98 pressure ulcer patients and 98 non-pressure ulcer patients. The quality and comprehensiveness of pressure ulcer documentation were measured by the modified European Pressure Ulcer Advisory Panel Pressure Ulcers Assessment Instrument and the Comprehensiveness in Nursing Documentation instrument. The correlations between quality/comprehensiveness of pressure ulcer documentation and incidence of pressure ulcers were not statistically significant. Patients with pressure ulcers had longer length of stay than patients without pressure ulcers stay. There were no statistically significant differences in quality/comprehensiveness scores of pressure ulcer documentation between dayshift and nightshift. This study revealed a lack of quality/comprehensiveness in nursing documentation of pressure ulcers. This study demonstrates that staff nurses often perform poorly on documenting pressure ulcer appearance, staging and treatment. Moreover, nursing documentation of pressure ulcers does not provide a complete picture of patients' care needs that require nursing interventions. The implication of this study involves pressure ulcer prevention and litigable risk of nursing documentation. © 2016 John Wiley & Sons Ltd.
Identifying palliative care issues in inpatients dying following stroke.
Ntlholang, O; Walsh, S; Bradley, D; Harbison, J
2016-08-01
Stroke leads to high mortality and morbidity but often there is a conflict between need for palliative care and avoidance of 'therapeutic nihilism'. We aimed to elicit the palliative care needs of stroke patients at the end of their lives in our unit with a low overall mortality rate (1 month: 8.8 %, inpatient: 12.9 %). We identified consecutive stroke patients who died over 2 years. Their clinical records were used for data collection. Of 54 deaths, 33 (61.1 %) were females, mean (SD) age at death was 79.3 ± 12.9 years. 41 (75.9 %) died after first stroke, 9 (16.7 %) were inpatient strokes, 7 (13.0 %) thrombolysed and 7 (13.0 %) had strokes as treatment complication. There were clear statements recorded in 26 (48.1 %) that patients were dying and death was thought to be due primarily to extent of brain injury in 24 (44.4 %). Palliative needs identified included dyspnoea 21 (38.9 %), pain 17 (31.5 %), respiratory secretions 17 (31.5 %), agitation 14 (25.9 %) and psychological distress 1 (1.9 %). Symptoms were due to premorbid diseases in 6 (11.1 %). Palliative care expertise were sought in 13 (24.1 %) and continuous subcutaneous infusion was used in 18 (33.3 %) to control symptoms. 4 (7.4 %) subjects underwent cardiac arrest calls and 9 (16.7 %) deaths occurred in ICU/HDU. The median Stroke-Death interval was 20 days (range 0-389). Do Not Attempt Resuscitation (DNAR) orders were in place in 86.8 % of patients. The median DNAR-Death interval was 7 days (range 0-311) with 7-day DNAR-Death rate of 53.2 % and 30-day of 78.7 % of the total deaths. Dyspnoea, pain and respiratory secretions were identified as the main palliative care needs.
Sving, Eva; Högman, Marieann; Mamhidir, Anna-Greta; Gunningberg, Lena
2016-10-01
The aim of the study was to evaluate whether a multi-faceted, unit-tailored intervention using evidenced-based pressure ulcer prevention affects (i) the performance of pressure ulcer prevention, (ii) the prevalence of pressure ulcers and (iii) knowledge and attitudes concerning pressure ulcer prevention among registered and assistant nurses. A quasi-experimental, clustered pre- and post-test design was used. Five units at a hospital setting were included. The intervention was based on the PARIHS framework and included a multi-professional team, training and repeated quality measurements. An established methodology was used to evaluate the prevalence and prevention of pressure ulcers. Nurses' knowledge and attitudes were evaluated using a validated questionnaire. A total of 506 patients were included, of whom 105 patients had a risk to develop pressure ulcer. More patients were provided pressure ulcer prevention care (P = 0·001) and more prevention care was given to each patient (P = 0·021) after the intervention. Corresponding results were shown in the group of patients assessed as being at risk for developing pressure ulcers. Nurses' knowledge about pressure ulcer prevention increased (P < 0·001). Positive attitudes towards pressure ulcer prevention remained high between pre- and post-test surveys. This multi-faceted unit-tailored intervention affected pressure ulcer prevention. Facilitation and repeated quality measurement together with constructed feedback of results seemed to be the most important factor for pressure ulcer prevention. © 2014 The Authors. International Wound Journal © 2014 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Electronic-type vacuum gauges with replaceable elements
Edwards, Jr., David
1984-01-01
In electronic devices for measuring pressures in vacuum systems, the metal elements which undergo thermal deterioration are made readily replaceable by making them parts of a simple plug-in unit. Thus, in ionization gauges, the filament and grid or electron collector are mounted on the novel plug-in unit. In thermocouple pressure gauges, the heater and attached thermocouple are mounted on the plug-in unit. Plug-in units have been designed to function, alternatively, as ionization gauge and as thermocouple gauge, thus providing new gauges capable of measuring broader pressure ranges than is possible with either an ionization gauge or a thermocouple gauge.
Water Ingestion into Axial Flow Compressors. Part III. Experimental Results and Discussion
1981-10-01
total pressure, static pressure, and temperature at both compressor inlet and outlet. A United Sensor model PDC-12-G-l0-KL pitot-static pressure probe...Test Compressor inlet and outlet temperatures during water injection tests: United Sensor and Control Corp. type TK-8-CiA-36’-F Aspirate...ured utilizing standard aspirated thermocouples, namely an United Sensor and Control Corp. type TK-8-C/A-36-F. The Test Compressor out- let
Development of an Inlet Pressure Sensor for Control in a Left Ventricular Assist Device
Fritz, Bryan; Cysyk, Joshua; Newswanger, Ray; Weiss, William; Rosenberg, Gerson
2010-01-01
A Tesla type continuous flow left ventricular assist device (VAD) has been designed by Penn State and Advanced Bionics, Inc. (ABI). When a continuous flow device is employed, care must be taken to limit low pressures in the ventricle that can produce an obstruction to the inlet cannula or trigger arrhythmias. Design of an inexpensive, semi-conductor strain gage inlet pressure sensor to detect suction has been completed. The research and design analysis included finite element modeling of the sensing region. Sensitivity, step-response, temperature dependence and hysteresis tests have been performed on prototype units. All sensors were able to withstand the maximum expected strain of 82 μin/in at 500 mmHg internal pressure. Average sensitivity was 0.52 ±0.24 μV/mmHg with 0.5 V excitation (n=5 units). Step response time for a 0 to 90 mmHg step change averaged 22 milliseconds. Hysteresis was measured by applying and holding 75mmHg internal pressure for 4 hours, followed by a zero pressure measurement, and ranged from -15 mmHg to 4.1 mmHg (n=3 units). Offset drift varied between 180 and -140 mmHg over a four week period. (n=2 units). Span temperature sensitivity ranged from 18 to -21 μV/°C (n=5 units). Gain temperature sensitivity ranged from -7.4 to 4.9 μV/°C (n=5 units). With the inherent drift, it is currently not possible to use the transducer to measure actual pressures, but it can easily be used to measure pressure changes throughout the cardiac cycle. This signal can then be used in the control system to avoid ventricular suction events. PMID:20335797
2000-10-01
To investigate the association between control of intraocular pressure after surgical intervention for glaucoma and visual field deterioration. In the Advanced Glaucoma Intervention Study, eyes were randomly assigned to one of two sequences of glaucoma surgery, one beginning with argon laser trabeculoplasty and the other trabeculectomy. In the present article we examine the relationship between intraocular pressure and progression of visual field damage over 6 or more years of follow-up. In the first analysis, designated Predictive Analysis, we categorize 738 eyes into three groups based on intraocular pressure determinations over the first three 6-month follow-up visits. In the second analysis, designated Associative Analysis, we categorize 586 eyes into four groups based on the percent of 6-month visits over the first 6 follow-up years in which eyes presented with intraocular pressure less than 18 mm Hg. The outcome measure in both analyses is change from baseline in follow-up visual field defect score (range, 0 to 20 units). In the Predictive Analysis, eyes with early average intraocular pressure greater than 17.5 mm Hg had an estimated worsening during subsequent follow-up that was 1 unit of visual field defect score greater than eyes with average intraocular pressure less than 14 mm Hg (P =.002). This amount of worsening was greater at 7 years (1.89 units; P <.001) than at 2 years (0.64 units; P =.071). In the Associative Analysis, eyes with 100% of visits with intraocular pressure less than 18 mm Hg over 6 years had mean changes from baseline in visual field defect score close to zero during follow-up, whereas eyes with less than 50% of visits with intraocular pressure less than 18 mm Hg had an estimated worsening over follow-up of 0.63 units of visual field defect score (P =.083). This amount of worsening was greater at 7 years (1.93 units; P <.001) than at 2 years (0.25 units; P =.572). In both analyses low intraocular pressure is associated with reduced progression of visual field defect, supporting evidence from earlier studies of a protective role for low intraocular pressure in visual field deterioration.
A system for the automatic measurement and digital display of systolic and diastolic blood pressures
NASA Technical Reports Server (NTRS)
Schulze, A. E.
1971-01-01
Basic components of system are - occluding cuff with mounted cuff microscope, cuff pump deflator, pressure transducer, preamplifier unit, electrocardiograph machine, an analog to digital convertor unit, and digital display unit. System utilizes indirect auscultatory method, based on Korotkoff sounds, for measurement.
Measurement of Infrasound from the Marine Environment
2015-09-01
ocean heave, which are due to the change in the background atmospheric pressure as the sensor moves up and down. An external inertial measurement unit ... inertial measurement unit (IMU) was used to estimate the heave, and was highly correlated with the pressure interference signal. Mission area... MEASUREMENT UNIT ..................................................... 13 ADAPTIVE NOISE CANCELATION
Measurement of Intrasound from the Marine Environment
2015-09-01
external inertial measurement unit (IMU) was used to estimate the heave, and was highly correlated with the pressure interference signal...moves up and down. An external inertial measurement unit (IMU) was used to estimate the heave, and was highly correlated with the pressure...10 EXTERNAL INTEGRATED MEASUREMENT UNIT ..................................................... 13 ADAPTIVE NOISE CANCELATION
... High blood pressure Slurred speech Are these drugs legal in the United States? Some of these drugs ... High blood pressure Slurred speech Are these drugs legal in the United States? Some of these drugs ...
75 FR 13142 - Florida Power and Light Company; Turkey Point, Units 3 and 4; Exemption
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-18
... Light Company; Turkey Point, Units 3 and 4; Exemption 1.0 Background Florida Power and Light Company... ferritic materials of pressure-retaining components of the reactor coolant pressure boundary of light water... reactor coolant pressure boundary of light water nuclear power reactors to provide adequate margins of...
Improvement of a sensor unit for wrist blood pressure monitoring system
NASA Astrophysics Data System (ADS)
Koo, Sangjun; Kwon, Jongwon; Park, Yongman; Ayuzenara, Odgerel; Kim, Hiesik
2007-12-01
A blood pressure sensor unit for ubiquitous healthcare monitoring was newly developed. The digital wrist band-type blood pressure devices for home are popular already in the market. It is useful for checking blood pressure level at home and control of hypertension. Especially, it is very essential home device to check the health condition of blood circulation disease. Nowadays many product types are available. But the measurement of blood pressure is not accurate enough compared with the mechanical type. It needs to be upgraded to assure the precise health data enough to use in the hospital. The structure, feature and output signal of capacitor type pressure sensors are analyzed. An improved design of capacitor sensor is suggested. It shows more precise health data after use on a wrist band type health unit. They can be applied for remote u-health medical service.
Electronic-type vacuum gauges with replaceable elements
Edwards, D. Jr.
1984-09-18
In electronic devices for measuring pressures in vacuum systems, the metal elements which undergo thermal deterioration are made readily replaceable by making them parts of a simple plug-in unit. Thus, in ionization gauges, the filament and grid or electron collector are mounted on the novel plug-in unit. In thermocouple pressure gauges, the heater and attached thermocouple are mounted on the plug-in unit. Plug-in units have been designed to function, alternatively, as ionization gauge and as thermocouple gauge, thus providing new gauges capable of measuring broader pressure ranges than is possible with either an ionization gauge or a thermocouple gauge. 5 figs.
77 FR 61303 - Airworthiness Directives; Turbomeca S.A. Turboshaft Engines
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-09
...-mechanical metering unit (HMU). This proposed AD would require replacing the HMU at a reduced life. We are... pressure/low pressure (HP/LP) pump assembly within the hydro- mechanical metering unit (HMU), removed...-mechanical metering unit (HMU). We are issuing this AD to prevent an uncommanded in-flight shutdown of the...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-04
... as technical reports related to the Gas Turbine Generator design. The Subcommittee will hear... Subcommittee on United States-Advanced Pressurized Water Reactor (US-APWR); Notice of Meeting The ACRS Subcommittee on United States-Advanced Pressurized Water Reactor (US-APWR) will hold a meeting on April 22...
Global Pressure- and Temperature-Measurements in 1.27-m JAXA Hypersonic Wind Tunnel
NASA Astrophysics Data System (ADS)
Yamada, Y.; Miyazaki, T.; Nakagawa, M.; Tsuda, S.; Sakaue, H.
Pressure-sensitive paint (PSP) technique has been widely used in aerodynamic measurements. A PSP is a global optical sensor, which consists of a luminophore and binding material. The luminophore gives a luminescence related to an oxygen concentration known as oxygen quenching. In an aerodynamic measurement, the oxygen concentration is related to a partial pressure of oxygen and a static pressure, thus the luminescent signal can be related to a static pressure [1]. The PSP measurement system consists of a PSP coated model, an image acquisition unit, and an image processing unit (Fig. 1). For the image acquisition, an illumination source and a photo-detector are required. To separate the illumination and PSP emission detected by a photo-detector, appropriate band-pass filters are placed in front of the illumination and photo-detector. The image processing unit includes the calibration and computation. The calibration relates the luminescent signal to pressures and temperatures. Based on these calibrations, luminescent images are converted to a pressure map.
Perspectives for a new realization of the pascal by optical methods
NASA Astrophysics Data System (ADS)
Jousten, Karl; Hendricks, Jay; Barker, Daniel; Douglas, Kevin; Eckel, Steve; Egan, Patrick; Fedchak, James; Flügge, Jens; Gaiser, Christof; Olson, Douglas; Ricker, Jacob; Rubin, Tom; Sabuga, Wladimir; Scherschligt, Julia; Schödel, Rene; Sterr, Uwe; Stone, Jack; Strouse, Gregory
2017-12-01
Since the beginning of measurement of pressure in the 17th century, the unit of pressure has been defined by the relationship of force per unit area. The present state of optical technology now offers the possibility of using a thermodynamic definition—specifically the ideal gas law—for the realization of the pressure unit, in the vacuum regime and slightly above, with an accuracy comparable to or better than the traditional methods of force per area. The changes planned for the SI in 2018 support the application of this thermodynamic definition that is based on the ideal gas law with the necessary corrections for real-gas effects. The paper reviews the theoretical and experimental foundations of those optical methods that are considered to be most promising to realize the unit of pressure at the highest level of metrology.
Improving flexibility characteristics of 200 MW unit
NASA Astrophysics Data System (ADS)
Taler, Jan; Trojan, Marcin; Taler, Dawid; Dzierwa, Piotr; Kaczmarski, Karol
2017-03-01
Calculations were performed of the thermal system of a power plant with installed water pressure tanks. The maximum rise in the block electric power resulting from the shut-off of low-pressure regenerative heaters is determined. At that time, the boiler is fed with hot water from water pressure tanks acting as heat accumulators. Accumulation of hot water in water tanks is also proposed in the periods of the power unit small load. In order to lower the plant electric power in the off-peak night hours, water heated in low-pressure regenerative heaters and feed water tank to the nominal temperature is directed to water pressure tanks. The water accumulated during the night is used to feed the boiler during the period of peak demand for electricity. Drops in the power block electric power were determined for different capacities of the tanks and periods when they are charged. A financial and economic profitability analysis (of costs and benefits) is made of the use of tanks for a 200 MW power unit. Operating in the automatic system of frequency and power control, the tanks may also be used to ensure a sudden increase in the electric power of the unit. The results of the performed calculations and analyses indicate that installation of water pressure tanks is well justified. The investment is profitable. Water pressure tanks may not only be used to reduce the power unit power during the off-peak night hours and raise it in the periods of peak demand, but also to increase the power capacity fast at any time. They may also be used to fill the boiler evaporator with hot water during the power unit start-up from the cold state.
NASA Astrophysics Data System (ADS)
Silin, V. A.; Zorin, V. M.; Tagirov, A. M.; Tregubova, O. I.; Belov, I. V.; Povarov, P. V.
2010-12-01
Main results obtained from calculations of the steam generator and thermal circuit of the steam turbine unit for a nuclear power unit with supercritical-pressure water coolant and integral layout are presented. The obtained characteristics point to the advisability of carrying out further developments of this promising nuclear power technology.
Brunelli, Alessandro; Charloux, Anne; Bolliger, Chris T; Rocco, Gaetano; Sculier, Jean-Paul; Varela, Gonzalo; Licker, Marc; Ferguson, Mark K; Faivre-Finn, Corinne; Huber, Rudolf Maria; Clini, Enrico M; Win, Thida; De Ruysscher, Dirk; Goldman, Lee
2009-07-01
The European Respiratory Society (ERS) and the European Society of Thoracic Surgeons (ESTS) established a joint task force with the purpose to develop clinical evidence-based guidelines on evaluation of fitness for radical therapy in patients with lung cancer. The following topics were discussed, and are summarized in the final report along with graded recommendations: Cardiologic evaluation before lung resection; lung function tests and exercise tests (limitations of ppoFEV1; DLCO: systematic or selective?; split function studies; exercise tests: systematic; low-tech exercise tests; cardiopulmonary (high tech) exercise tests); future trends in preoperative work-up; physiotherapy/rehabilitation and smoking cessation; scoring systems; advanced care management (ICU/HDU); quality of life in patients submitted to radical treatment; combined cancer surgery and lung volume reduction surgery; compromised parenchymal sparing resections and minimally invasive techniques: the balance between oncological radicality and functional reserve; neoadjuvant chemotherapy and complications; definitive chemo and radiotherapy: functional selection criteria and definition of risk; should surgical criteria be re-calibrated for radiotherapy?; the patient at prohibitive surgical risk: alternatives to surgery; who should treat thoracic patients and where these patients should be treated?
[Ophthalmodynamometry in the diagnostics of Grave's ophthalmopathy].
Harder, B; Jonas, J B
2007-11-01
Since endocrine orbitopathy is characterised by exophthalmos and increased orbital tissue pressure which may lead to a compression of and damage to the optic nerve, it was the purpose of this study to evaluate whether the increased orbital tissue pressure in endocrine orbitopathy is associated with an elevated central retinal vein pressure as estimated by ophthalmodynamometry, and whether the central retinal vein pressure changes in the course of the disease. The prospective clinical study included 7 patients (13 eyes) with endocrine orbitopathy. They were screened for the prevalence of a spontaneous pulsation of the central retinal vein. In case of a missing spontaneous pulse, the collapse pressure of the central retinal vein was estimated by a modified ophthalmodynamometry using a corneal contact lens associated ophthalmodynamometric device. A group of 122 patients (156 eyes) without orbital or retinal diseases served as control group. The frequency of a spontaneous pulse of the central retinal vein was significantly lower in the study group (1/13 or 8%) than in the control group (121/156 or 78% p<0.001; odds ratio: 41.5). The central retinal vein collapse pressure as determined by ophthalmodynamometry was significantly higher in the study group (22.7+/-19.5 arbitrary units) than in the control group (4.7+/-12.8 arbitrary units) (p=0.002). For one patient with 7 examinations during a follow-up of 16 months, the central retinal vein pressure increased from 17 arbitrary units to 56 units, and decreased to 14 to 19 arbitrary units after initiation of a systemic therapy and regression of the exophthalmos. Three years later a spontaneous pulsation of the central retinal vein was detectable. Ophthalmodynamometry may be a useful examination for the indirect assessment of the orbital tissue pressure in patients with endocrine orbitopathy.
Prophylactic Sacral Dressing for Pressure Ulcer Prevention in High-Risk Patients.
Byrne, Jaime; Nichols, Patricia; Sroczynski, Marzena; Stelmaski, Laurie; Stetzer, Molly; Line, Cynthia; Carlin, Kristen
2016-05-01
Patients in intensive care units are likely to have limited mobility owing to hemodynamic instability and activity orders for bed rest. Bed rest is indicated because of the severity of the disease process, which often involves intubation, sedation, paralysis, surgical procedures, poor nutrition, low flow states, and poor circulation. These patients are predisposed to the development and/or the progression of pressure ulcers not only because of their underlying diseases, but also because of limited mobility and deconditioned states of health. To assess whether treating high-risk patients with a prophylactic sacral dressing decreases the incidence of unit-acquired sacral pressure ulcers. An evidence-based tool for identifying patients at high risk for pressure ulcers was used in 3 intensive care units at an urban tertiary care hospital and academic medical center. Those patients deemed at high risk had a prophylactic sacral dressing applied. Incidence rates were collected and compared for the 7 months preceding use of the dressings and for 7 months during the trial period when the dressing was used. After the sacral dressing began being used, the number of unit-acquired sacral pressure ulcers decreased by 3.4 to 7.6 per 1000 patient days depending on the unit. A prophylactic sacral dressing may help prevent unit-acquired sacral pressure ulcers. Implementation of an involved care team with heightened awareness and increased education along with a prophylactic sacral dressing in patients deemed high risk for skin breakdown are all essential for success. ©2016 American Association of Critical-Care Nurses.
49 CFR 232.409 - Inspection and testing of end-of-train devices.
Code of Federal Regulations, 2013 CFR
2013-10-01
... be determined, after charging the train, by comparing the quantitative value of the air pressure displayed on the front unit with the quantitative value of the air pressure displayed on the rear unit or on...
49 CFR 232.409 - Inspection and testing of end-of-train devices.
Code of Federal Regulations, 2010 CFR
2010-10-01
... be determined, after charging the train, by comparing the quantitative value of the air pressure displayed on the front unit with the quantitative value of the air pressure displayed on the rear unit or on...
49 CFR 232.409 - Inspection and testing of end-of-train devices.
Code of Federal Regulations, 2014 CFR
2014-10-01
... be determined, after charging the train, by comparing the quantitative value of the air pressure displayed on the front unit with the quantitative value of the air pressure displayed on the rear unit or on...
49 CFR 232.409 - Inspection and testing of end-of-train devices.
Code of Federal Regulations, 2012 CFR
2012-10-01
... be determined, after charging the train, by comparing the quantitative value of the air pressure displayed on the front unit with the quantitative value of the air pressure displayed on the rear unit or on...
49 CFR 232.409 - Inspection and testing of end-of-train devices.
Code of Federal Regulations, 2011 CFR
2011-10-01
... be determined, after charging the train, by comparing the quantitative value of the air pressure displayed on the front unit with the quantitative value of the air pressure displayed on the rear unit or on...
NASA Astrophysics Data System (ADS)
Ambarita, H.; Sihombing, H. V.
2018-03-01
Vapor compression cycle is mainly employed as a refrigeration cycle in the Air-Conditioning (AC) unit. In order to save energy, the Coefficient of Performance (COP) of the need to be improved. One of the potential solutions is to modify the system into multi-stages vapor compression cycle. The suitable intermediate pressure between the high and low pressures is one of the design issues. The present work deals with the investigation of an optimum intermediate pressure of two-stages vapor compression refrigeration cycle. Typical vapor compression cycle that is used in AC unit is taken into consideration. The used refrigerants are R134a. The governing equations have been developed for the systems. An inhouse program has been developed to solve the problem. COP, mass flow rate of the refrigerant and compressor power as a function of intermediate pressure are plotted. It was shown that there exists an optimum intermediate pressure for maximum COP. For refrigerant R134a, the proposed correlations need to be revised.
ERIC Educational Resources Information Center
Pleger, Lyn; Sager, Fritz; Morris, Michael; Meyer, Wolfgang; Stockmann, Reinhard
2017-01-01
Pressure on evaluators has been investigated recently by surveys in the USA, the UK, Germany, and Switzerland. This study compares the results of those studies regarding pressure on evaluators in different countries. The findings suggest that independence of evaluations does not exist for many respondents. Moreover, the person who commissioned the…
Common pressure vessel development for the nickel hydrogen technology
NASA Technical Reports Server (NTRS)
Holleck, G.
1981-01-01
The design of a pressure vessel nickel hydrogen cell is described. The cell has the following key features: it eliminates electrolyte bridging; provides for independent electrolyte management for each unit stack; provides for independent oxygen management for each unit stack; has good heat dissipation; has a mechanically sound and practical interconnection; and has the maximum in common with state of the art individual pressure vessel technology.
The effect of nurse manager turnover on patient fall and pressure ulcer rates.
Warshawsky, Nora; Rayens, Mary Kay; Stefaniak, Karen; Rahman, Rana
2013-07-01
The purpose of this study was to explore the effects of nurse manager turnover on the occurrence of adverse events. Nurse managers create professional nurse practice environments to support the provision of quality patient outcomes. Inconsistent findings were reported in the literature testing the relationship between nurse managers and patient outcomes. All prior studies assumed stable nursing management. A longitudinal quasi-experimental study of 23 nursing units in two hospitals was used to determine whether unit characteristics, including nurse manager turnover, have an effect on patient falls or pressure ulcers. Statistical analyses included repeated measures and hierarchical modelling. Patients in medical/surgical units experienced more falls than in intensive care units (F1,11 = 15.9, P = 0.002). Patients in units with a nurse manager turnover [odds ratio: 3.16; 95% confidence interval: 1.49-6.70] and intensive care units (odds ratio: 2.70; 95% confidence interval: 1.33-5.49) were more likely to develop pressure ulcers. Nurse manager turnover and intensive care unit status were associated with more pressure ulcers. Medical/surgical unit status was associated with more falls. The study was limited by a small sample size. Nurse manager turnover may negatively impact patient outcomes. Stable nursing management, strategic interim management and long-term succession planning may reduce adverse patient events. © 2013 John Wiley & Sons Ltd.
Brown, Stephen H M; Gregory, Diane E; McGill, Stuart M
2008-01-01
In a healthy spine, end-plate fractures occur from excessive pressurization of the intervening nucleus. Younger spines are most susceptible to such type of injury due to the highly hydraulic nature of their intervertebral discs. The purpose of this paper was to confirm this fracture mechanism of the healthy spine through the pressurization of the nucleus in the absence of external compressive loading. Sixteen functional porcine spine units were dissected and both injection and pressure transducer needles were inserted into the nucleus of the intervertebral disc. Hydraulic fluid was rapidly injected into the nucleus until failure occurred. Peak pressure and rate of pressure development were monitored. Spine units were dissected to determine the type and location of fracture. Fifteen of the 16 spine units fractured (the remaining unit had a degenerated disc). Of the 15 fractures, 13 occurred at the posterior margin of the end-plate along the lines of the growth plates. A slightly exponential relationship was found between peak pressure and its rate of development (R(2) = 0.544). Also, in each of the growth-plate fractured specimens, nuclear material was forcefully emitted, during fracture, from the intervertebral disc into the vertebral foramen. The posterior end-plate fractures produced here are similar to those often seen in young adult humans. This provides insight into a mechanism of fracture development through pressurization of the nucleus that might be seen in older adolescents and younger adults during athletic events or mild trauma.
Luo, Hong-Ji; Lin, Shi-Xiang; Wu, Shyi-Kuen; Tsai, Mei-Wun; Lee, Shwn-Jen
2017-01-01
Postural rehabilitation emphasizing on motor control training of segmental spinal movements has been proposed to effectively reduce the scoliotic spinal deformities in adolescent idiopathic scoliosis (AIS). However, information regarding the impairments of segmental spinal movement control involving segmental spinal stabilizers in adolescent idiopathic scoliosis remains limited. Examination of segmental spinal movement control may provide a window for investigating the features of impaired movement control specific to spinal segments that may assist in the development of physiotherapeutic management of AIS. To compare segmental spinal movement control in adolescents with and without idiopathic scoliosis using modified pressure biofeedback unit. Segmental spinal movement control was assessed in twenty adolescents with idiopathic scoliosis (AISG) and twenty healthy adolescents (CG) using a modified pressure biofeedback unit. Participants performed segmental spinal movements that primarily involved segmental spinal stabilizing muscles with graded and sustained muscle contraction against/off a pressure cuff from baseline to target pressures and then maintained for 1 min. Pressure data during the 1-minute maintenance phase were collected for further analysis. Pressure deviation were calculated and compared between groups. The AISG had significantly greater pressure deviations for all segmental spinal movements of cervical, thoracic, and lumbar spine than the CG. Pressure biofeedback unit was feasible for assessing segmental spinal movement control in AIS. AISG exhibited poorer ability to grade and sustain muscle activities for local movements of cervical, thoracic, and lumbar spine, suggesting motor control training of segmental spinal movements involving segmental spinal stabilizing muscles on frontal, sagittal, and transverse planes were required.
Pressure-assisted thermal sterilization of soup
NASA Astrophysics Data System (ADS)
Shibeshi, Kidane; Farid, Mohammed M.
2010-12-01
The overall efficiency of an existing scale-up pressure-assisted thermal sterilization (PATS) unit was investigated with regards to inactivation of Geobacillus stearothermophilus spores suspended in pumpkin soup. The PATS unit is a double pipe heat exchanger in which the soup is pumped into its inner high pressure tube and constrained by two high pressure valves, while steam is continuously passed through the annular region to heat the content. The technology is based on pressure generation by thermal expansion of the liquid in an enclosure. In this work, the addition of an air line to push the treated liquid food out of the existing PATS unit has improved the overall quality of the treated samples, as evidenced by achieving higher log reduction of the spores. Compared with thermal processing, the application of PATS shows the potential for lowering the thermal treatment temperature, offering improved food quality.
Optical detection system for MEMS-type pressure sensor
NASA Astrophysics Data System (ADS)
Sareło, K.; Górecka-Drzazga, A.; Dziuban, J. A.
2015-07-01
In this paper a special optical detection system designed for a MEMS-type (micro-electro-mechanical system) silicon pressure sensor is presented. The main part of the optical system—a detection unit with a perforated membrane—is bonded to the silicon sensor, and placed in a measuring system. An external light source illuminates the membrane of the pressure sensor. Owing to the light reflected from the deflected membrane sensor, the optical pattern consisting of light points is visible, and pressure can be estimated. The optical detection unit (20 × 20 × 20.4 mm3) is fabricated using microengineering techniques. Its dimensions are adjusted to the dimensions of the pressure sensor (5 × 5 mm2 silicon membrane). Preliminary tests of the optical detection unit integrated with the silicon pressure sensor are carried out. For the membrane sensor from 15 to 60 µm thick, a repeatable detection of the differential pressure in the range of 0 to 280 kPa is achieved. The presented optical microsystem is especially suitable for the pressure measurements in a high radiation environment.
Amniotic fluid embolism: an Australian-New Zealand population-based study.
McDonnell, Nolan; Knight, Marian; Peek, Michael J; Ellwood, David; Homer, Caroline S E; McLintock, Claire; Vaughan, Geraldine; Pollock, Wendy; Li, Zhuoyang; Javid, Nasrin; Sullivan, Elizabeth
2015-12-24
Amniotic fluid embolism (AFE) is a major cause of direct maternal mortality in Australia and New Zealand. There has been no national population study of AFE in either country. The aim of this study was to estimate the incidence of amniotic fluid embolism in Australia and New Zealand and to describe risk factors, management, and perinatal outcomes. A population-based descriptive study using the Australasian Maternity Outcomes Surveillance System (AMOSS) carried out in 263 eligible sites (>50 births per year) covering an estimated 96% of women giving birth in Australia and all 24 New Zealand maternity units (100% of women giving birth in hospitals) between January 1 2010-December 31 2011. A case of AFE was defined either as a clinical diagnosis (acute hypotension or cardiac arrest, acute hypoxia and coagulopathy in the absence of any other potential explanation for the symptoms and signs observed) or as a post mortem diagnosis (presence of fetal squames/debris in the pulmonary circulation). Thirty-three cases of AFE were reported from an estimated cohort of 613,731women giving birth, with an estimated incidence of 5.4 cases per 100,000 women giving birth (95% CI 3.5 to 7.2 per 100,000). Two (6%) events occurred at home whilst 46% (n = 15) occurred in the birth suite and 46% (n = 15) in the operating theatre (location not reported in one case). Fourteen women (42%) underwent either an induction or augmentation of labour and 22 (67%) underwent a caesarean section. Eight women (24%) conceived using assisted reproduction technology. Thirteen (42%) women required cardiopulmonary resuscitation, 18% (n = 6) had a hysterectomy and 85% (n = 28) received a transfusion of blood or blood products. Twenty (61%) were admitted to an Intensive Care Unit (ICU), eight (24%) were admitted to a High Dependency Unit (HDU) and seven (21%) were transferred to another hospital for further management. Five woman died (case fatality rate 15%) giving an estimated maternal mortality rate due to AFE of 0.8 per 100,000 women giving birth (95% CI 0.1% to 1.5%). There were two deaths among 36 infants. A coordinated emergency response requiring resource intense multi-disciplinary input is required in the management of women with AFE. Although the case fatality rate is lower than in previously published studies, high rates of hysterectomy, resuscitation, and admission to higher care settings reflect the significant morbidity associated with AFE. Active, ongoing surveillance to document the risk factors and short and long-term outcomes of women and their babies following AFE may be helpful to guide best practice, management, counselling and service planning. A potential link between AFE and assisted reproductive technology warrants further investigation.
Pennell, William E.; Rowan, William J.
1977-01-01
A nuclear reactor in which the core components, including fuel-rod assemblies, control-rod assemblies, fertile rod-assemblies, and removable shielding assemblies, are supported by a plurality of separate inlet modular units. These units are referred to as inlet module units to distinguish them from the modules of the upper internals of the reactor. The modular units are supported, each removable independently of the others, in liners in the supporting structure for the lower internals of the reactor. The core assemblies are removably supported in integral receptacles or sockets of the modular units. The liners, units, sockets and assmblies have inlet openings for entry of the fluid. The modular units are each removably mounted in the liners with fluid seals interposed between the opening in the liner and inlet module into which the fluid enters and the upper and lower portion of the liner. Each assembly is similarly mounted in a corresponding receptacle with fluid seals interposed between the openings where the fluid enters and the lower portion of the receptacle or fitting closely in these regions. As fluid flows along each core assembly a pressure drop is produced along the fluid so that the fluid which emerges from each core assembly is at a lower pressure than the fluid which enters the core assembly. However because of the seals interposed in the mountings of the units and assemblies the pressures above and below the units and assemblies are balanced and the units are held in the liners and the assemblies are held in the receptacles by their weights as they have a higher specific gravity than the fluid. The low-pressure spaces between each module and its liner and between each core assembly and its module is vented to the low-pressure regions of the vessel to assure that fluid which leaks through the seals does not accumulate and destroy the hydraulic balance.
Vibration isolation and pressure compensation apparatus for sensitive instrumentation
NASA Technical Reports Server (NTRS)
Averill, R. D. (Inventor)
1983-01-01
A system for attenuating the inherent vibration associated with a mechanical refrigeration unit employed to cryogenically cool sensitive instruments used in measuring chemical constituents of the atmosphere is described. A modular system including an instrument housing and a reaction bracket with a refrigerator unit floated there between comprise the instrumentation system. A pair of evacuated bellows that "float' refrigerator unit and provide pressure compensation at all levels of pressure from seal level to the vacuum of space. Vibration isolators and when needed provide additional vibration damping for the refrigerator unit. A flexible thermal strap (20 K) serves to provide essentially vibration free thermal contact between cold tip of the refrigerator unit and the instrument component mounted on the IDL mount. Another flexible strap (77 K) serves to provide vibration free thermal contact between the TDL mount thermal shroud and a thermal shroud disposed about the thermal shaft.
142. STANDBY PRESSURE CONTROL UNIT FOR FUEL AND LIQUID OXYGEN ...
142. STANDBY PRESSURE CONTROL UNIT FOR FUEL AND LIQUID OXYGEN IN SOUTHWEST PORTION OF CONTROL ROOM (214), LSB (BLDG. 751), FACING WEST - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
Calibratable solid-state pressure switch
NASA Technical Reports Server (NTRS)
1969-01-01
Pressure switch, incorporating a semiconductor light-detector coupled to an electrically controlled actuating unit, provides accurate and reliable switching over a broad range of pressures and environments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
The most common method of measuring air leakage is to perform single (or solo) blower door pressurization and/or depressurization test. In detached housing, the single blower door test measures leakage to the outside. In attached housing, however, this "solo" test method measures both air leakage to the outside and air leakage between adjacent units through common surfaces. Although minimizing leakage to neighboring units is highly recommended to avoid indoor air quality issues between units, reduce pressure differentials between units, and control stack effect, the energy benefits of air sealing can be significantly overpredicted if the solo air leakage number ismore » used in the energy analysis. Guarded blower door testing is more appropriate for isolating and measuring leakage to the outside in attached housing. This method uses multiple blower doors to depressurize adjacent spaces to the same level as the unit being tested. Maintaining a neutral pressure across common walls, ceilings, and floors acts as a "guard" against air leakage between units. The resulting measured air leakage in the test unit is only air leakage to the outside. Although preferred for assessing energy impacts, the challenges of performing guarded testing can be daunting.« less
SI Units to be Used in Place of Imperial Units and Old Metric Units
ERIC Educational Resources Information Center
Australian Science Teachers Journal, 1975
1975-01-01
A table lists the following quantities in imperial units, old metric units, and SI units: mass, force, energy, torque, power, pressure, temperature, thermal conductivity, frequency, dynamic viscosity, and kinematic viscosity. (MLH)
A High Pressure Post-Perovskite Phase Transition in NaMgF3--a MgSiO3 Analog Material
NASA Astrophysics Data System (ADS)
Martin, C.; Liu, H.; Crichton, W.; Parise, J. B.
2005-12-01
Since Murakami et al. (2004) identified a perovskite (pv, Pbnm) to post-perovskite (ppv, Cmcm) structural phase transition in MgSiO3, the transition has been reported to occur in many oxides at ultra-high pressures (>60 GPa). The layered ppv structure is rapidly shaping a better understanding of seismic anisotropy in the controversial D" region of the lower mantle. While the ppv unit cell may be derived from indexing of the powder pattern, the structure adopted at high pressure is experimentally ill-constrained due to compromised powder diffraction statistics typically obtained from small sample volumes at extreme conditions in the diamond anvil cell. NaMgF3, a structural analog material to MgSiO3 pv, exhibits a large compressibility and presents the possibility of reducing the pv-ppv transition pressure, allowing for improved powder statistics from a larger sample volume. In accordance with our previous theoretical and experimental evidence (Liu et al., 2005; Parise et al., 2004), we have observed a phase transition in NaMgF3 during two recent independent high pressure trials utilizing monochromatic x-ray diffraction and in-situ laser heating in the diamond anvil cell at pressures as low as 30 GPa. From our analysis thus far, we have found the unit cell of the high pressure phase cannot be indexed according to pv (Pbnm) or close permutations of ppv (Cmcm) unit cells predicted for NaMgF3 or unit cells observed for ppv MgSiO3 and MgGeO3. In addition, we have precluded a breakdown to high pressure phases of NaF and MgF3 as an explanation for the observed data. Upon pressure release, we observe diffraction peaks from the high pressure phase in the absence of pv NaMgF3, suggesting the high pressure structure is quenchable to ambient conditions. The results of the work in progress will be presented at the meeting.
A microfluidic circulatory system integrated with capillary-assisted pressure sensors.
Chen, Yangfan; Chan, Ho Nam; Michael, Sean A; Shen, Yusheng; Chen, Yin; Tian, Qian; Huang, Lu; Wu, Hongkai
2017-02-14
The human circulatory system comprises a complex network of blood vessels interconnecting biologically relevant organs and a heart driving blood recirculation throughout this system. Recreating this system in vitro would act as a bridge between organ-on-a-chip and "body-on-a-chip" and advance the development of in vitro models. Here, we present a microfluidic circulatory system integrated with an on-chip pressure sensor to closely mimic human systemic circulation in vitro. A cardiac-like on-chip pumping system is incorporated in the device. It consists of four pumping units and passive check valves, which mimic the four heart chambers and heart valves, respectively. Each pumping unit is independently controlled with adjustable pressure and pump rate, enabling users to control the mimicked blood pressure and heartbeat rate within the device. A check valve is located downstream of each pumping unit to prevent backward leakage. Pulsatile and unidirectional flow can be generated to recirculate within the device by programming the four pumping units. We also report an on-chip capillary-assisted pressure sensor to monitor the pressure inside the device. One end of the capillary was placed in the measurement region, while the other end was sealed. Time-dependent pressure changes were measured by recording the movement of the liquid-gas interface in the capillary and calculating the pressure using the ideal gas law. The sensor covered the physiologically relevant blood pressure range found in humans (0-142.5 mmHg) and could respond to 0.2 s actuation time. With the aid of the sensor, the pressure inside the device could be adjusted to the desired range. As a proof of concept, human normal left ventricular and arterial pressure profiles were mimicked inside this device. Human umbilical vein endothelial cells (HUVECs) were cultured on chip and cells can respond to mechanical forces generated by arterial-like flow patterns.
Techno-economic Analysis of Acid Gas Removal and Liquefaction for Pressurized LNG
NASA Astrophysics Data System (ADS)
Lee, S. H.; Seo, Y. K.; Chang, D. J.
2018-05-01
This study estimated the life cycle cost (LCC) of an acid gas removal and a liquefaction processes for Pressurized LNG (PLNG) production and compared the results with the cost of normal LNG production. PLNG is pressurized LNG that is liquefied at a higher pressure and temperature than normal LNG. Due to the high temperature, the energy for liquefaction is reduced. The allowable CO2 concentration in PLNG is increased up to 3 mol% when the product pressure 25 bar. An amine process with 35 wt% of diethanolamine (DEA) aqueous solution and a nitrogen expansion cycle were selected for the acid gas removal and the liquefaction processes, respectively. Two types of CO2 concentration in the feed gas were investigated to analyze their impacts on the acid gas removal unit. When the CO2 concentration was 5 mol%, the acid gas removal unit was required for both LNG and PLNG production. However, the acid gas removal unit was not necessary in PLNG when the concentration was 0.5 mol% and the pressure was higher than 15 bar. The results showed that the LCC of PLNG was reduced by almost 35% relative to that of LNG when the PLNG pressure was higher than 15 bar.
Portable tester for determining gas content within a core sample
Garcia, Jr., Fred; Schatzel, Steven J.
1998-01-01
A portable tester is provided for reading and displaying the pressure of a gas released from a rock core sample stored within a sealed container and for taking a sample of the released pressurized gas for chemical analysis thereof for subsequent use in a modified direct method test which determines the volume of gas and specific type of gas contained within the core sample. The portable tester includes a pair of low and high range electrical pressure transducers for detecting a gas pressure; a pair of low and high range display units for displaying the pressure of the detected gas- a selector valve connected to the low and high range pressure transducers, a selector knob for selecting gas flow to one of the flow paths; control valve having an inlet connection to the sealed container, and outlets connected to: a sample gas canister, a second outlet port connected to the selector valve means for reading the pressure of the gas from the sealed container to either the low range or high range pressure transducers, and a connection for venting gas contained within the sealed container to the atmosphere. A battery is electrically connected to and supplies the power for operating the unit. The pressure transducers, display units, selector and control valve means and the battery is mounted to and housed within a protective casing for portable transport and use.
Portable tester for determining gas content within a core sample
Garcia, F. Jr.; Schatzel, S.J.
1998-04-21
A portable tester is provided for reading and displaying the pressure of a gas released from a rock core sample stored within a sealed container and for taking a sample of the released pressurized gas for chemical analysis thereof for subsequent use in a modified direct method test which determines the volume of gas and specific type of gas contained within the core sample. The portable tester includes a pair of low and high range electrical pressure transducers for detecting a gas pressure; a pair of low and high range display units for displaying the pressure of the detected gas; a selector valve connected to the low and high range pressure transducers and a selector knob for selecting gas flow to one of the flow paths; control valve having an inlet connection to the sealed container; and outlets connected to: a sample gas canister, a second outlet port connected to the selector valve means for reading the pressure of the gas from the sealed container to either the low range or high range pressure transducers, and a connection for venting gas contained within the sealed container to the atmosphere. A battery is electrically connected to and supplies the power for operating the unit. The pressure transducers, display units, selector and control valve means and the battery is mounted to and housed within a protective casing for portable transport and use. 5 figs.
40 CFR 1065.20 - Units of measure and overview of calculations.
Code of Federal Regulations, 2014 CFR
2014-07-01
... temperatures in units of degrees Celsius ( °C) unless a calculation requires an absolute temperature. In that... °C equals 273.15 K. Unless specified otherwise, always use absolute temperature values for... substances, mg/kg, formerly ppm (mass). (c) Absolute pressure. Measure absolute pressure directly or...
Universal Pressure Ulcer Prevention Bundle With WOC Nurse Support.
Anderson, Megan; Finch Guthrie, Patricia; Kraft, Wendy; Reicks, Patty; Skay, Carol; Beal, Alan L
2015-01-01
This study examined the effectiveness of a universal pressure ulcer prevention bundle (UPUPB) applied to intensive care unit (ICU) patients combined with proactive, semiweekly WOC nurse rounds. The UPUBP was compared to a standard guideline with referral-based WOC nurse involvement measuring adherence to 5 evidence-based prevention interventions and incidence of pressure ulcers. The study used a quasi-experimental, pre-, and postintervention design in which each phase included different subjects. Descriptive methods assisted in exploring the content of WOC nurse rounds. One hundred eighty-one pre- and 146 postintervention subjects who met inclusion criteria and were admitted to ICU for more than 24 hours participated in the study. The research setting was 3 ICUs located at North Memorial Medical Center in Minneapolis, Minnesota. Data collection included admission/discharge skin assessments, chart reviews for 5 evidence-based interventions and patient characteristics, and WOC nurse rounding logs. Study subjects with intact skin on admission identified with an initial skin assessment were enrolled in which prephase subjects received standard care and postphase subjects received the UPUPB. Skin assessments on ICU discharge and chart reviews throughout the stay determined the presence of unit-acquired pressure ulcers and skin care received. Analysis included description of WOC nurse rounds, t-tests for guideline adherence, and multivariate analysis for intervention effect on pressure ulcer incidence. Unit assignment, Braden Scale score, and ICU length of stay were covariates for a multivariate model based on bivariate logistic regression screening. The incidence of unit-acquired pressure ulcers decreased from 15.5% to 2.1%. WOC nurses logged 204 rounds over 6 months, focusing primarily on early detection of pressure sources. Data analysis revealed significantly increased adherence to heel elevation (t = -3.905, df = 325, P < .001) and repositioning (t = -2.441, df = 325, P < .015). Multivariate logistic regression modeling showed a significant reduction in unit-acquired pressure ulcers (P < .001). The intervention increased the Nagelkerke R-Square value by 0.099 (P < .001) more than 0.297 (P < .001) when including only covariates, for a final model value of 0.396 (P < .001). The UPUPB with WOC nurse rounds resulted in a statistically significant and clinically relevant reduction in the incidence of pressure ulcers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koukoulas, Triantafillos, E-mail: triantafillos.koukoulas@npl.co.uk; Piper, Ben
Since the introduction of the International System of Units (the SI system) in 1960, weights, measures, standardised approaches, procedures, and protocols have been introduced, adapted, and extensively used. A major international effort and activity concentrate on the definition and traceability of the seven base SI units in terms of fundamental constants, and consequently those units that are derived from the base units. In airborne acoustical metrology and for the audible range of frequencies up to 20 kHz, the SI unit of sound pressure, the pascal, is realised indirectly and without any knowledge or measurement of the sound field. Though themore » principle of reciprocity was originally formulated by Lord Rayleigh nearly two centuries ago, it was devised in the 1940s and eventually became a calibration standard in the 1960s; however, it can only accommodate a limited number of acoustic sensors of specific types and dimensions. International standards determine the device sensitivity either through coupler or through free-field reciprocity but rely on the continuous availability of specific acoustical artefacts. Here, we show an optical method based on gated photon correlation spectroscopy that can measure sound pressures directly and absolutely in fully anechoic conditions, remotely, and without disturbing the propagating sound field. It neither relies on the availability or performance of any measurement artefact nor makes any assumptions of the device geometry and sound field characteristics. Most importantly, the required units of sound pressure and microphone sensitivity may now be experimentally realised, thus providing direct traceability to SI base units.« less
Gehring, J M; Cho, J-G; Wheatley, J R; Amis, T C
2014-03-01
We examined thermocouple and pressure cannulae responses to oral and nasal airflow using a polyester model of a human face, with patent nasal and oral orifices instrumented with a dual thermocouple (F-ONT2A, Grass) or a dual cannula (0588, Braebon) pressure transducer (± 10 cm H2O, Celesco) system. Tidal airflow was generated using a dual compartment facemask with pneumotachographs (Fleisch 2) connected to the model orifices. During nasal breathing: thermocouple amplitude = 0.38 Ln [pneumotachograph amplitude] + 1.31 and pressure cannula amplitude = 0.93 [pneumotachograph amplitude](2.15); during oral breathing: thermocouple amplitude = 0.44 Ln [pneumotachograph amplitude] + 1.07 and pressure cannula amplitude = 0.33 [pneumotachograph amplitude](1.72); (all range ∼ 0.1-∼ 4.0 L s(-1); r(2) > 0.7). For pneumotachograph amplitudes <1 L s(-1) (linear model) change in thermocouple amplitude/unit change in pneumotachograph amplitude was similar for nasal and oral airflow, whereas nasal pressure cannula amplitude/unit change in pneumotachograph amplitude was almost four times that for oral. Increasing oral orifice area from 0.33 cm(2) to 2.15 cm(2) increased oral thermocouple amplitude/unit change in pneumotachograph amplitude by ∼ 58% but decreased pressure cannula amplitude/unit change in pneumotachograph amplitude by 49%. For pneumotachograph amplitudes up to 1 L s(-1), alterations in inspiratory/expiratory ratios or total respiratory time did not affect the sensitivity of either nasal or oral pressure cannulae or the nasal thermocouple, but the oral thermocouple sensitivity was influenced by respiratory cycle time. Different nasal and oral responses influence the ability of these systems to quantitatively assess nasal and oral airflow and oro-nasal airflow partitioning.
Experimental study of air delivery into water-conveyance system of the radial-axial turbine
NASA Astrophysics Data System (ADS)
Maslennikova, Alexandra; Platonov, Dmitry; Minakov, Andrey; Dekterev, Dmitry
2017-10-01
The paper presents an experimental study of oscillatory response in the Francis turbine of hydraulic unit. The experiment was performed on large-scale hydrodynamic test-bench with impeller diameter of 0.3 m. The effect of air injection on the intensity of pressure pulsations was studied at the maximum pressure pulsations in the hydraulic unit. It was revealed that air delivery into the water-conveyance system of the turbine results in almost two-fold reduction of pressure pulsations.
40 CFR 1065.20 - Units of measure and overview of calculations.
Code of Federal Regulations, 2012 CFR
2012-07-01
... in units of degrees Celsius (°C) unless a calculation requires an absolute temperature. In that case..., formerly ppm (mass). (c) Absolute pressure. Measure absolute pressure directly or calculate it as the sum... at least one additional non-zero digit following the five, remove all the appropriate digits and...
40 CFR 1065.20 - Units of measure and overview of calculations.
Code of Federal Regulations, 2013 CFR
2013-07-01
... in units of degrees Celsius (°C) unless a calculation requires an absolute temperature. In that case..., formerly ppm (mass). (c) Absolute pressure. Measure absolute pressure directly or calculate it as the sum... at least one additional non-zero digit following the five, remove all the appropriate digits and...
Pressure Swing Adsorption in the Unit Operations Laboratory
ERIC Educational Resources Information Center
Ganley, Jason
2018-01-01
This paper describes a student laboratory in the Unit Operations Laboratory at the Colorado School of Mines: air separation by pressure swing adsorption. The flexibility of the system enables students to study the production of enriched nitrogen or oxygen streams. Automatic data acquisition permits the study of cycle steps and performance.…
Haftka, Joris J H; Parsons, John R; Govers, Harrie A J
2006-11-24
A gas chromatographic method using Kováts retention indices has been applied to determine the liquid vapour pressure (P(i)), enthalpy of vaporization (DeltaH(i)) and difference in heat capacity between gas and liquid phase (DeltaC(i)) for a group of polycyclic aromatic hydrocarbons (PAHs). This group consists of 19 unsubstituted, methylated and sulphur containing PAHs. Differences in log P(i) of -0.04 to +0.99 log units at 298.15K were observed between experimental values and data from effusion and gas saturation studies. These differences in log P(i) have been fitted with multilinear regression resulting in a compound and temperature dependent correction. Over a temperature range from 273.15 to 423.15K, differences in corrected log P(i) of a training set (-0.07 to +0.03 log units) and a validation set (-0.17 to 0.19 log units) were within calculated error ranges. The corrected vapour pressures also showed a good agreement with other GC determined vapour pressures (average -0.09 log units).
Mitz, Andrew R
2005-10-15
Behavioral neurophysiology and other kinds of behavioral research often involve the delivery of liquid rewards to experimental subjects performing some kind of operant task. Available systems use gravity or pumps to deliver these fluids, but such methods are poorly suited to moment-to-moment control of the volume, timing, and type of fluid delivered. The design described here overcomes these limitations using an electronic control unit, a pressurized reservoir unit, and an electronically controlled solenoid. The control unit monitors reservoir pressure and provides precisely timed solenoid activation signals. It also stores calibration tables and does on-the-fly interpolation to support computer-controlled delivery calibrated directly in milliliters. The reservoir provides pressurized liquid to a solenoid mounted near the subject. Multiple solenoids, each supplied by a separate reservoir unit and control unit, can be stacked in close proximity to allow instantaneous selection of which liquid reward is delivered. The precision of droplet delivery was verified by weighing discharged droplets on a commercial analytical balance.
Hermetic Seal Leak Detection Apparatus
NASA Technical Reports Server (NTRS)
Kelley, Anthony R. (Inventor)
2013-01-01
The present invention is a hermetic seal leak detection apparatus, which can be used to test for hermetic seal leaks in instruments and containers. A vacuum tight chamber is created around the unit being tested to minimize gas space outside of the hermetic seal. A vacuum inducing device is then used to increase the gas chamber volume inside the device, so that a slight vacuum is pulled on the unit being tested. The pressure in the unit being tested will stabilize. If the stabilized pressure reads close to a known good seal calibration, there is not a leak in the seal. If the stabilized pressure reads closer to a known bad seal calibration value, there is a leak in the seal. The speed of the plunger can be varied and by evaluating the resulting pressure change rates and final values, the leak rate/size can be accurately calculated.
Ozyurek, Pakize; Yavuz, Meryem
2015-01-01
The aim of this study is to compare whether differences exist between 2 viscoelastic foam support surfaces in the development of new pressure ulcers. There is evidence to support the use of viscoelastic foam over standard hospital foam to reduce pressure. A comparative effectiveness study was done to compare 2 viscoelastic foam support surfaces. A randomized controlled trial was carried out. The study was performed in 2 intensive care units between October 1, 2008, and January 4, 2010. Patients (n = 105) admitted to intensive care unit were randomly assigned to viscoelastic foam 1 (n = 53) or viscoelastic foam 2 support surface (n = 52). In total, 42.8% of all patients developed a new pressure ulcer of stage 1 or worse. By stages, pressure ulcer incidence was 28.6%, 13.3%, and 1.0% for stages 1, 2, and 3, respectively. There was no significant difference in pressure ulcer incidence between the viscoelastic foam 1 and 2 groups (X2 = 0.07, df = 1, P > .05). No difference was found between 2 different viscoelastic foam surfaces in the prevention of pressure ulcers in patients treated in intensive care. Pressure ulcer incidence in critically ill patients remains high. Nurses must compare current products for effectiveness and develop innovative systems, processes, or devices to deliver best practices.
Cornish, J A; Tekkis, P P; Tan, E; Tilney, H S; Thompson, M R; Smith, J J
2011-06-01
To investigate the relationship between organisational structure, process and surgical outcomes for bowel cancer surgery. An e-survey was sent to the members of the Association of Coloproctology of Great Britain and Ireland to determine the organisational structure of their Trusts. Responses were combined with the National Bowel Cancer Audit (NBOCAP) data. Items investigated included; number of consultants, nurse specialists, volume of cases and intensive care facilities. Main outcome measures included: 30-day risk-adjusted mortality, length of stay (LOS), lymph node yield and circumferential margin involvement (CRM). One hundred and seventeen Trusts responded (65.8%), matched to 7666 patient episodes (NBOCAP data) from 54 (62.8%)Trusts who submitted data to the audit. Trusts treating <190 cases/annum (p > 0.001), <4 colorectal consultants (p > 0.001), <4 HDU beds (p > 0001) and <8 ITU beds (p > 0001) were more likely to have a 30-day-risk-adjusted mortality twice that of the national mean. Sixty five percent (n = 1603) of Trusts treating ≥ 190 cases/annum harvested ≥ 12 lymph nodes vs. 58.3% (n = 1435) in Trusts <190 cases/annum (p < 0.001). Trusts with ≥ 2 pathologists with an interest in bowel cancer harvested ≥ 12 lymph nodes more frequently (p=<0.001) and were more likely to identify extramural vascular invasion in the specimen (p = 0.015). Negative CRM was achieved in 81.4% (n = 81.4) of patients in Trusts treating ≥ 190 cases vs. 66.5% (n = 569) in Trusts<190 cases/annum (p < 0.001). Trusts offering fast track discharge were more likely to have a LOS < 15 days (p = 0.006). Surgeons treating ≤ 35 cases/annum had increased major post-operative complications (<35 cases = 70.2% vs. ≥ 35 cases = 21.9%; p < 0.001), however 30 day risk adjusted mortality was not increased in surgeons treating <35 cases/annum. This study shows that the organisational infrastructure of hospitals appears to have as great an impact on patient outcomes as the volume of cases performed by hospital Trusts. Crown Copyright © 2010. Published by Elsevier Ltd. All rights reserved.
Hastings, Mary K; Mueller, Michael J; Sinacore, David R; Strube, Michael J; Crowner, Beth E; Johnson, Jeffrey E; Racette, Brad R
2012-05-01
High forefoot plantar pressure is associated with plantar ulcers in people with diabetes and peripheral neuropathy. The purpose of this pilot study was to determine the safety and efficacy of botulinum toxin A injected into the gastrocnemius-soleus muscles to reduce muscle strength and plantar pressure. This double blind, randomized clinical trial studied 17 people with diabetes mellitus, peripheral neuropathy and a forefoot plantar ulcer. Subjects were randomized into one of three groups receiving gastrocnemius-soleus muscle injections on the involved side with; 1) Saline (n = 5, weight =99± 21 kg), 2) 200-units of Botox® (n = 7, weight = 101± 5 kg), or 3) 300-units of Botox® (n = 5, weight = 129± 22 kg). Botox® dose was converted to units/kg, the majority received between 1.9 and 2.4 units/kg (n = 11) and one 3.2 units/kg. Plantarflexor peak torque and forefoot peak plantar pressure were quantified prior and 2 weeks post-injection. There were no complications from the injections. Plantarflexor peak torque on the involved side increased in the placebo and 300 groups (3± 4 Nm and 6± 10 Nm, respectively) and decreased -8± 11 Nm in the 200 group. There was no relationship between units/kg of Botox® for each subject and change in plantarflexor peak torque. Forefoot peak plantar pressure did not change in the placebo and 300 groups (0± 11 and 0± 5 N/cm(2), respectively) and decreased -4± 16 N/cm2 (4%) for the 200 group. There were no adverse events associated with the Botox® injections. This study was unable to determine the dose to consistently reduce plantarflexor strength and forefoot plantar pressure. Additional research is needed to investigate diabetes mellitus specific physiological changes and their impact of BoNT-A effectiveness in order to guide appropriate dosing.
What role can nurse leaders play in reducing the incidence of pressure sores?
Wurster, Joan
2007-01-01
Pressure sores have plagued the nursing profession for many years as a major health care problem in terms of a patient's suffering and financial cost. Pressure sores are increasingly common in hospitalized patients in the United States with a 63% increase from 1993 to 2003. The nurse leader is accountable for the occurrence of pressure sores, a nurse-sensitive indicator, by a scorecard which is benchmarked against other facilities. The nurse leader must take a systematic approach in the prevention of pressure sores, with the strategy being consistent and motivating to the staff in order to improve patient outcome. The chief nursing officer, the unit manager, and the bedside nurse must all collaborate to prevent tissue injury in patients at risk for developing pressure sores and to promote wound healing in patients with existing breakdown.
Continuous recording of pulmonary artery pressure in unrestricted subjects.
Ikram, H; Richards, A M; Hamilton, E J; Nicholls, M G
1984-01-01
Continuous ambulatory pulmonary artery pressures were recorded using a conventional No 5 French Goodale-Lubin filled catheter linked to the Oxford Medilog system of a portable transducer-perfusion unit and miniaturised recorder. Data retrieval and analysis were performed using a PB2 Medilog playback unit linked to a PDP 11 computer system. The total system has a frequency response linear to 8 Hz allowing accurate pressure recording over the full range of heart rates. Ten recordings in 10 patients yielded artefact free data for 80% or more of the recorded period. This inexpensive reliable method allows pulmonary artery pressures to be recorded in unrestricted subjects. Images PMID:6704262
Serum diamine oxidase activity as a diagnostic test for histamine intolerance.
Mušič, Ema; Korošec, Peter; Šilar, Mira; Adamič, Katja; Košnik, Mitja; Rijavec, Matija
2013-05-01
Histamine intolerance (HIT) is characterized by an imbalance between histamine intake and the capacity for histamine degradation. The main enzyme for metabolizing ingested histamine is diamine oxidase (DAO). Determining DAO activity in serum may be useful in diagnosing HIT. Over a period of 3.5 years we recruited 316 subjects with clinically suspected HIT and 55 healthy controls. Serum DAO activity was measured with a quantitative enzyme immunoassay. Twenty patients with highly reduced DAO activity went on a histamine-free diet for 6-12 months. Afterwards, their DAO activity was determined again. We found that DAO activity was significantly lower in patients than in healthy control subjects (P < 0.0001). Furthermore, 54 patients had highly reduced serum DAO activity (< 40 HDU/ml). Their main symptoms involved the skin, gastrointestinal tract, respiratory system, and eyes. In all the 20 patients with highly reduced DAO activity, the main clinical symptoms typical of histamine intolerance disappeared after they adopted a histamine-free diet. Furthermore, the serum DAO activity values measured increased significantly (P < 0.0001). Our results suggest that determining DAO activity in serum is a useful tool in diagnosing HIT. Furthermore, our results showed the benefit of a histamine-free diet because after the diet the majority of symptoms disappeared and the serum DAO activity significantly increased.
A pressure-packer system for conducting rising head tests in water table wells
Levy, Benjamin S.; Pannell, Lawrence J.; Dadoly, John P.
1993-01-01
The pressure system developed for fully-saturated well screens has been modified for conducting rising head tests in water table wells installed in highly permeable aquifers. The pressure system consists of a compressed air source and 1 inch diameter PVC piping with a packer attached at the end. The pressure system was evaluated in a series of rising head tests conducted in a well at a Superfund site in New England. The well was tested with slugs and with the pressure system. Within each technique, estimates of hydraulic conductivity showed no difference. Comparison of hydraulic conductivity estimates between techniques (slug test vs. pressure test) showed differences due to stratigraphy. The interval tested using slug tests crossed two stratigraphic units; the pressure system tested only one of these units. We conclude that the pressure system may be used to characterize the vertical hydraulic conductivity distribution in a series of successive tests by changing the packer position and the screened interval tested.
Rodrigues, Warren; Carr, Michelle; Ridout, Deborah; Carter, Katherine; Hulme, Sara Louise; Simmonds, Jacob; Elliott, Martin; Hoskote, Aparna; Burch, Michael; Brown, Kate L
2011-11-01
Single-center studies have failed to link modest increases in total donor ischemic time to mortality after pediatric orthotopic heart transplant. We aimed to investigate whether prolonged total donor ischemic time is linked to pediatric intensive care morbidity after orthotopic heart transplant. Retrospective cohort review. Tertiary pediatric transplant center in the United Kingdom. Ninety-three pediatric orthotopic heart transplants between 2002 and 2006. Total donor ischemic time was investigated for association with early post-orthotopic heart transplant hemodynamics and intensive care unit morbidities. Of 43 males and 50 females with median age 7.2 (interquartile range 2.2, 13.0) yrs, 62 (68%) had dilated cardiomyopathy, 20 (22%) had congenital heart disease, and nine (10%) had restrictive cardiomyopathy. The mean total donor ischemic time was 225.9 (sd 65.6) mins. In the first 24 hrs after orthotopic heart transplant, age-adjusted mean arterial blood pressure increased (p < .001), mean pulmonary arterial pressure fell (p = .012), but central venous pressure (p = .58) and left atrial pressure (p = .20) were unchanged. After adjustment for age, primary diagnosis, pre-orthotopic heart transplant mechanical support, and marginal donor factors, longer total donor ischemic time was significantly associated with lower mean arterial blood pressure (p < .001) in the first 24 hrs after orthotopic heart transplant, longer post-orthotopic heart transplant mechanical ventilation (p = .03), longer post-orthotopic heart transplant stay in the intensive care unit (p = .004), and longer post-orthotopic heart transplant stay in hospital (p = .02). Total donor ischemic time was not related to levels of mean pulmonary arterial pressure (p = .62), left atrial pressure (p = .38), or central venous pressure (p = .76) early after orthotopic heart transplant. Prolonged total donor ischemic time has an adverse effect on the donor organ, contributing to lower mean arterial blood pressure, as well as more prolonged ventilation and intensive care unit and hospital stays post-orthotopic heart transplant, reflecting increased morbidity.
Compatibility of pressure sensitive adhesives with recycling unit operations
David Bormett; Carl Houtman; Said Abubakr; Joseph Peng
1999-01-01
Removal of pressure sensitive adhesives (PSAs) from recovered paper is a major problem facing the paper recycling industry. As a result of a United States Postal Service (USPS) initiative, which currently purchases about 12% of domestic PSA production, a team was formed consisting of representatives from the USPS, the Forest Products Laboratory, Springborn Testing and...
Launcher Dynamic Data Acquisition
2012-07-31
K PR Pressure PR Pressure PR Accelerometer PR Accelerometer PR Accelerometer PR Pressure PR Pressure IEPE Microphone IEPE ...transducers, displacement potentiometers, or Integrated Electronics Piezoelectric ( IEPE ) microphones and accelerometers. The characteristics of these...Engineering Units HCl hydrogen chloride HVAC heating ventilation and cooling Hz hertz IEC International Electrotechnical Commission IEPE
Osmotically-assisted desalination method and system
Achilli, Andrea; Childress, Amy E.; Cath, Tzahi Y.
2014-08-12
Systems and methods for osmotically assisted desalination include using a pressurized concentrate from a pressure desalination process to pressurize a feed to the desalination process. The depressurized concentrate thereby produced is used as a draw solution for a pressure-retarded osmosis process. The pressure-retarded osmosis unit produces a pressurized draw solution stream that is used to pressurize another feed to the desalination process. In one example, the feed to the pressure-retarded osmosis process is impaired water.
40 CFR 53.56 - Test for effect of variations in ambient pressure.
Code of Federal Regulations, 2010 CFR
2010-07-01
... measurement accuracy. (iv) Coefficient of variability measurement accuracy. (v) Ambient pressure measurement... through the sample filter, measured in actual volume units at the temperature and pressure of the air as... volumetric flow rate corrections are made based on measurements of actual ambient temperature and pressure...
Generational Differences in Resistance to Peer Pressure among Mexican-Origin Adolescents.
ERIC Educational Resources Information Center
Umana-Taylor, Adriana J.; Bamaca-Gomez, Mayra Y.
2003-01-01
Examined whether Mexican origin adolescents who varied by generational status would differ in their resistance to peer pressure. After controlling for gender, resistance to peer pressure varied significantly by generational status. Adolescents with no familial births in the United States were significantly more resistant to peer pressure than…
Cantilever arrayed blood pressure sensor for arterial applanation tonometry.
Lee, Byeungleul; Jeong, Jinwoo; Kim, Jinseok; Kim, Bonghwan; Chun, Kukjin
2014-03-01
The authors developed a cantilever-arrayed blood pressure sensor array fabricated by (111) silicon bulk-micromachining for the non-invasive and continuous measurement of blood pressure. The blood pressure sensor measures the blood pressure based on the change in the resistance of the piezoresistor on a 5-microm-thick-arrayed perforated membrane and 20-microm-thick metal pads. The length and the width of the unit membrane are 210 and 310 microm, respectively. The width of the insensible zone between the adjacent units is only 10 microm. The resistance change over contact force was measured to verify the performance. The good linearity of the result confirmed that the polydimethylsiloxane package transfers the forces appropriately. The measured sensitivity was about 4.5%/N. The maximum measurement range and the resolution of the fabricated blood pressure sensor were greater than 900 mmHg (= 120 kPa) and less than 1 mmHg (= 133.3 Pa), respectively.
Performance Analyses of 38 kWe Turbo-Machine Unit for Space Reactor Power Systems
NASA Astrophysics Data System (ADS)
Gallo, Bruno M.; El-Genk, Mohamed S.
2008-01-01
This paper developed a design and investigated the performance of 38 kWe turbo-machine unit for space nuclear reactor power systems with Closed Brayton Cycle (CBC) energy conversion. The compressor and turbine of this unit are scaled versions of the NASA's BRU developed in the sixties and seventies. The performance results of turbo-machine unit are calculated for rotational speed up to 45 krpm, variable reactor thermal power and system pressure, and fixed turbine and compressor inlet temperatures of 1144 K and 400 K. The analyses used a detailed turbo-machine model developed at the University of New Mexico that accounts for the various energy losses in the compressor and turbine and the effect of compressibility of the He-Xe (40 mole/g) working fluid with increased flow rate. The model also accounts for the changes in the physical and transport properties of the working fluid with temperature and pressure. Results show that a unit efficiency of 24.5% is achievable at rotation speed of 45 krpm and system pressure of 0.75 MPa, assuming shaft and electrical generator efficiencies of 86.7% and 90%. The corresponding net electric power output of the unit is 38.5 kWe, the flow rate of the working fluid is 1.667 kg/s, the pressure ratio and polytropic efficiency for the compressor are 1.60 and 83.1%, and 1.51 and 88.3% for the turbine.
Volume and structural relaxation in compressed sodium borate glass.
Svenson, Mouritz N; Youngman, Randall E; Yue, Yuanzheng; Rzoska, Sylwester J; Bockowski, Michal; Jensen, Lars R; Smedskjaer, Morten M
2016-11-21
The structure and properties of glass can be modified through compression near the glass transition temperature (T g ), and such modified structure and properties can be maintained at ambient temperature and pressure. However, once the compressed glass undergoes annealing near T g at ambient pressure, the modified structure and properties will relax. The challenging question is how the property relaxation is correlated with both the local and the medium-range structural relaxation. In this paper, we answer this question by studying the volume (density) and structural relaxation of a sodium borate glass that has first been pressure-quenched from its T g at 1 GPa, and then annealed at ambient pressure under different temperature-time conditions. Using 11 B MAS NMR and Raman spectroscopy, we find that the pressure-induced densification of the glass is accompanied by a conversion of six-membered rings into non-ring trigonal boron (B III ) units, i.e. a structural change in medium-range order, and an increase in the fraction of tetrahedral boron (B IV ), i.e. a structural change in short-range order. These pressure-induced structural conversions are reversible during ambient pressure annealing near T g , but exhibit a dependence on the annealing temperature, e.g. the ring/non-ring B III ratio stabilizes at different values depending on the applied annealing temperature. We find that conversions between structural units cannot account for the pressure-induced densification, and instead we suggest the packing of structural units as the main densification mechanism.
Maximizing water use efficiency in designing microirrigation unit (IrriLab Software)
NASA Astrophysics Data System (ADS)
Baiamonte, Giorgio
2016-04-01
As the year 2050 approaches, the world population will reach 9 billion - so does the challenge of doubling crop yields. To meet this crop yields demand, the associated dramatic improving of water productivity (WP) must necessarily be accompanied by maximization of water use efficiency (WUE) (Ragab 2011, UNEP 2014). In this work, a recently developed software (IrriLab, https://www.facebook.com/irrilab) moving in this direction is presented. IrriLab is a very simple toll allows to design microirrigation unit optimizing WUE, pressure energy and irrigation unit costs. Irrigation software available in commerce provide microirrigation system designs, by mainly looking at the maximum flow rate uniformity criteria. Thus, each emitter installed along the laterals operates with an operating pressure head occurring in between an established range of pressure head variability (Dh < Dhadm). However, the latter condition does not always corresponds to the cheapest and to the maximizing WUE solution; in fact, it is not assured if the entire range of the admitted pressure head is profited and used by the emitters. IrriLab allows this occurrence because, for the entire Irrigation Unit Area, IUA, each design solution assures that at least two emitters rigorously operates, one with the minimum admitted pressure head, and the other one with the maximum admitted (Dh = Dhadm), (Baiamonte et al., 2015; Baiamonte, 2016). The same extreme values of pressure head are those that in the common design criteria delimit the range of pressure head, but without assuring their achievement. Compared to the common design criteria, this condition i) for fixed laterals' length and inside diameter, allows reducing the inlet required pressure head whereas, ii) for fixed pressure head at the inlet, provides an increasing in laterals and manifold lengths and in the associated IUA. Based on analytical solutions, IrriLab follows a very simple rectangular sketch, any way oriented in the space, and defined by two slope values, one for the laterals and one for the manifold. By considering the possible combinations of i) horizontal, downward or upward sloped laterals and manifold, ii) the manifold position in respect to the laterals and iii) the inlet position in respect to the manifold, which can be equal to 0%, 24% or 50%, in respect to their lengths (Baiamonte, 2016), IrriLab accounts for 25 optimal irrigation unit layouts, for each of them providing maximum WUE.
[Cuff pressure control at the intersinve care unit: influence of nursing professionals' training].
Velasco Sanz, T R; Ronda Delgado de la Fuente, M; Sánchez de la Ventana, A B; Reyes Merino Martínez, M
2015-01-01
To analyze proper control of endotracheal cuff pressure in an intensive care unit. The specific objective is to verify whether training of nursing professionals improves monitoring endotracheal cuff pressure. the study type is descriptive, observational and retrospective. All patients were admitted to the Critical Unit II of the Clínico San Carlos Hospital between May 2010-November 2011, requiring either a tracheal tube or tracheal cannula. Studied variables were: number of in range measures, number of intubated patients, or with tracheal cannula and register. Four cuts were made on all admitted patients admitted during the study period in order to measure endotracheal cuff pressure. Two cuts were performed before the professional nurses training and the other two cuts after a specific training with respect to endotracheal cuff pressure and Zero pneumonia. There were 74 measurements. The first cut obtained 40.74% of measures in range. In the second cut 61.90% of measures were identified in range. In the third cut, it was found that 85.7% of measures were in range and in the fourth court, it was noted the 89.47% of measures were in range. Monitoring of the endotracheal cuff pressure was inadequate before specific training of professionals. Nursing professionals training facilitates the correct measurement of the endotracheal cuff pressure, which improves patient safety. Copyright © 2013 Elsevier España, S.L.U. y SEEIUC. All rights reserved.
A microfluidic distribution system for an array of hollow microneedles
NASA Astrophysics Data System (ADS)
Hoel, Antonin; Baron, Nolwenn; Cabodevila, Gonzalo; Jullien, Marie-Caroline
2008-06-01
We report a microfluidic device able to control the ejection of fluid through a matrix of out-of-plane microneedles. The device comprises a matrix of open dispensing units connected to needles and filled by a common filling system. A deformable membrane (e.g. in PDMS) is brought into contact with the dispensing units. Pressure exerted on the deformable membrane closes (and thus individualizes) each dispensing unit and provokes the ejection of the dispensing unit content through the outlets. Sufficient pressure over the deformable membrane ensures that all dispensing units deliver a fixed volume (their content) irrespective of the hydrodynamic pressure outside the dispensing unit outlet. The size of the ensemble matrix of dispensing units, the number of liquid reservoirs, as well as the material can vary depending on the considered application of the device or on the conditions of use. In the present paper, the liquid reservoirs are geometrically identical. The geometrical parameters of the device are optimized to avoid as much dead volume as possible, as it was to handle plasmid DNA solutions which are very expensive. The conception, the fabrication and the experimental results are described in this paper. Our prototype is conceived to inject in a uniform way 10 µl of drug through 100 microneedles distributed over 1 cm2.
18. SHEAR PIN, UNIT 24 GORGE POWERHOUSE. THE WICKET GATES ...
18. SHEAR PIN, UNIT 24 GORGE POWERHOUSE. THE WICKET GATES ON THE TURBINE ARE EACH EQUIPPED WITH A SHEAR PIN AND OIL PRESSURE GAUGE. IF A GATE JAMS, THE PIN SMEARS AND THE CHANGE IN OIL PRESSURE TRIGGERS AN ALARM, 1989. - Skagit Power Development, Gorge Powerhouse, On Skagit River, 0.4 mile upstream from Newhalem, Newhalem, Whatcom County, WA
Browns Ferry Unit-3 cavity neutron spectral analysis. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, G.C.
1981-08-01
This report describes neutron dosimetry measurements performed in the Browns Ferry Unit-3 reactor cavity using multiple dosimeter and spectrum unfolding techniques to assess radiation-induced degradation of nuclear plant pressure vessels. Test results and conclusions indicating the feasibility of determining neutron flux spectra and the densities in the pressure vessel cavity region via dosimetric measurements are presented.
Nicolas, B; Moiziard, A S; Barrois, B; Colin, D; Michel, J M; Passadori, Y; Ribinik, P
2012-10-01
Implementation of a prevention strategy after the identification of risk factors is essential at the entrance in a care unit or in a medical-social unit. Determine which medical devices and which treatments may be used in order to prevent pressure sore in 2012. Systematic review of the literature using databases: Pascal, Biomed, PubMed, and Cochrane library between 2000 and 2010. Nursing care including use of soft product, non-irritating for the cleaning, hydration of the skin with emollients, protection of fragile skin in case of incontinence by applying a skin protector and application of dressings in front of bony prominences to reduce shear forces, remain valid (level C). Nursing cares and use of dressing in patients with high risks of pressure sores are the responsibility of the nurses. The engagement of health care teams involves screening of risk factors and the knowledge of treatments and local devices. Local preventive treatment in a patient with risk factors of pressure sore is of great interest at entrance in a care unit or in a medical-social unit. Copyright © 2012. Published by Elsevier Masson SAS.
Deflection of the local interstellar dust flow by solar radiation pressure
NASA Technical Reports Server (NTRS)
Landgraf, M.; Augustsson, K.; Grun, E.; Gustafson, B. A.
1999-01-01
Interstellar dust grains intercepted by the dust detectors on the Ulysses and Galileo spacecrafts at heliocentric distances from 2 to 4 astronomical units show a deficit of grains with masses from 1 x 10(-17) to 3 x 10(-16) kilograms relative to grains intercepted outside 4 astronomical units. To divert grains out of the 2- to 4-astronomical unit region, the solar radiation pressure must be 1.4 to 1.8 times the force of solar gravity. These figures are consistent with the optical properties of spherical or elongated grains that consist of astronomical silicates or organic refractory material. Pure graphite grains with diameters of 0.2 to 0.4 micrometer experience a solar radiation pressure force as much as twice the force of solar gravity.
Zielstorff, R D; Estey, G; Vickery, A; Hamilton, G; Fitzmaurice, J B; Barnett, G O
1997-01-01
A decision support system for prevention and management of pressure ulcers was developed based on AHCPR guidelines and other sources. The system was implemented for 21 weeks on a 20-bed clinical care unit. Fifteen nurses on that unit volunteered as subjects of the intervention to see whether use of the system would have a positive effect on their knowledge about pressure ulcers and on their decision-making skills related to this topic. A similar care unit was used as a control. In addition, the system was evaluated by experts for its instructional adequacy, and by end users for their satisfaction with the system. Preliminary results show no effect on knowledge about pressure ulcers and no effect on clinical decision making skills. The system was rated positively for instructional adequacy, and positively for user satisfaction. User interviews related to satisfaction supplemented the quantitative findings. A discussion of the issues of conducting experiments like this in today's clinical environment is included.
Field Testing of Compartmentalization Methods for Multifamily Construction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ueno, K.; Lstiburek, J.
The 2012 IECC has an airtightness requirement of 3 air changes per hour at 50 Pascals test pressure for both single-family and multifamily construction in Climate Zones 3-8. Other programs (LEED, ASHRAE 189, ASHRAE 62.2) have similar or tighter compartmentalization requirements, driving the need for easier and more effective methods of compartmentalization in multifamily buildings. Builders and practitioners have found that fire-resistance rated wall assemblies are a major source of difficulty in air sealing/compartmentalization, particularly in townhouse construction. This problem is exacerbated when garages are “tucked in” to the units and living space is located over the garages. In thismore » project, Building Science Corporation examined the taping of exterior sheathing details to improve air sealing results in townhouse and multifamily construction, when coupled with a better understanding of air leakage pathways. Current approaches are cumbersome, expensive, time consuming, and ineffective; these details were proposed as a more effective and efficient method. The effectiveness of these air sealing methods was tested with blower door testing, including “nulled” or “guarded” testing (adjacent units run at equal test pressure to null out inter-unit air leakage, or “pressure neutralization”). Pressure diagnostics were used to evaluate unit-to-unit connections and series leakage pathways (i.e., air leakage from exterior, into the fire-resistance rated wall assembly, and to the interior).« less
Hospital-acquired pressure ulcer prevalence--evaluating low-air-loss beds.
Johnson, Jane; Peterson, Darcie; Campbell, Betty; Richardson, Regina; Rutledge, Dana
2011-01-01
Higher-category pressure redistribution mattresses are considered a critical component of a pressure ulcer prevention program, but few studies have quantified the impact of specific preventive measures on the incidence or prevalence of hospital-acquired pressure ulcers (HAPUs). Therefore, this study was undertaken to determine the impact of low-air-loss beds on HAPU prevalence. This prospective, comparative cohort study monitored the prevalence of HAPU at our hospital and compared rates of matched medical-surgical units with and without low-air-loss beds. Units without low-air-loss beds used a variety of alternative pressure redistribution devices for patients deemed at risk for pressure ulceration. The prevalence of HAPU was operationally defined as the number of patients with HAPUs divided by numbers of patients observed. The prevalence of HAPU over 3 quarters in 2008 ranged from 1.0% to 3.3% (overall rate 2.4%). Eighty-three percent of patients with HAPUs were cared for on low-air-loss beds. Of 12 patients with 16 HAPUs during this time, 75% were aged 70 years or older and 25% were managed in critical care units. Over half of patients who developed HAPUs had been hospitalized for 20 days or more. Half of the patients with HAPUs were scored as no-low risk on the Braden Scale.On the paired medical-surgical units, no statistically significant differences were found when patients with low-air-loss beds were compared to standard hospital mattresses supplemented by a variety of pressure redistribution devices. Seven of 11 HAPUs (63%) occurred in patients placed on low-air-loss beds. The prevalence of HAPU in patients placed on low-air-loss beds was no different from patients placed on standard hospital mattresses supplemented by a variety of pressure redistribution devices. Further research is needed to determine the impact of specific strategies on prevention of HAPU.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Filippiadis, Dimitrios K., E-mail: dfilippiadis@yahoo.gr; Mazioti, A., E-mail: argyromazioti@yahoo.gr; Papakonstantinou, O., E-mail: sogofianol@gmail.com
Purpose: To illustrate quantitative discomanometry's (QD) diagnostic efficacy and predictive value in discogenic-pain evaluation in a prospective study correlating intradiscal pressure values with pain reduction after percutaneous image-guided technique (i.e., percutaneous decompression, PD). Materials and Methods: During the last 3 years, 36 patients [21 male and 15 female (mean age 36 {+-} 5.8 years)] with intervertebral disc hernia underwent QD before PD. Under absolute sterilization and fluoroscopy, a mixture of contrast medium and normal saline (3:1 ratio) was injected. A discmonitor performed a constant rate injection and recorded pressure and volume values, thus producing the relative pressure-volume curve. PD wasmore » then performed. Pain reduction and improved mobility were recorded at 3, 12, and 24 months after PD using clinical evaluation and a numeric visual scale (NVS; 0 to 10 units). Results: Mean pain values of 7.5 {+-} 1.9 (range 4 to 8) NVS units were recorded before PD; these decreased to 2.9 {+-} 2.44 at 3 months, 1.0 {+-} 1.9 at 12 months, and 1.0 {+-} 1.9 NVS units at 24 months after PD. Recorded correlations (pressure, volume, significant pain-reduction values) with bilateral statistical significance included a maximum injected volume of 2.4 ml (p = 0.045), P{sub o} < 14 psi [initial pressure required to inject 0.1 ml of the mixture inside the disc (p = 0.05)], P{sub max} {<=} 65 psi [greatest pressure value on the curve (p = 0.018)], and P{sub max} - P{sub o} {<=} 47 psi (p = 0.038). Patients meeting these pressure or volume cut-off points, either independently or as a total, had significant pain reduction (>4 NVS units) after PD. No complications were noted. Conclusions: QD is an efficient technique that may have predictive value for discogenic pain evaluation. It might serve as a useful tool for patient selection for intervertebral disc therapies.« less
Battery-Free Smart Sock for Abnormal Relative Plantar Pressure Monitoring.
Lin, Xiaoyou; Seet, Boon-Chong
2017-04-01
This paper presents a new design of a wearable plantar pressure monitoring system in the form of a smart sock for sensing abnormal relative pressure changes. One advantage of this approach is that with a battery-free design, this system can be powered solely by radio frequency (RF) energy harvested from a radio frequency identification (RFID) reader unit hosted on a smartphone of the wearer. At the same time, this RFID reader can read foot pressure values from an embedded sensor-tag in the sock. A pressure sensing matrix made of conductive fabric and flexible piezo-resistive material is integrated into the sock during the knitting process. Sensed foot pressures are digitized and stored in the memory of a sensor-tag, thus allowing relative foot pressure values to be tracked. The control unit of the smart sock is assembled on a flexible printed circuit board (FPC) that can be strapped to the lower limb and detached easily when it is not in use. Experiments show that the system can operate reliably in both tasks of RF energy harvesting and pressure measurement.
Development of a compact wearable pneumatic drive unit for a ventricular assist device.
Homma, Akihiko; Taenaka, Yoshiyuki; Tatsumi, Eisuke; Akagawa, Eiki; Lee, Hwansung; Nishinaka, Tomohiro; Takewa, Yoshiaki; Mizuno, Toshihide; Tsukiya, Tomonori; Kakuta, Yukihide; Katagiri, Nobumasa; Shimosaki, Isao; Hamada, Shigeru; Mukaibayashi, Hiroshi; Iwaoka, Wataru
2008-01-01
The purpose of this study was to develop a compact wearable pneumatic drive unit for a ventricular assist device (VAD). This newly developed drive unit, 20 x 8.5 x 20 cm in size and weighing approximately 1.8 kg, consists of a brushless DC motor, noncircular gears, a crankshaft, a cylinder-piston, and air pressure regulation valves. The driving air pressure is generated by the reciprocating motion of the piston and is controlled by the air pressure regulation valves. The systolic ratio is determined by the noncircular gears, and so is fixed for a given configuration. As a result of an overflow-type mock circulation test, a drive unit with a 44% systolic ratio connected to a Toyobo VAD blood pump with a 70-ml stroke volume achieved a pump output of more than 7 l/min at 100 bpm against a 120 mmHg afterload. Long-term animal tests were also performed using drive units with systolic ratios of 45% and 53% in two Holstein calves weighing 62 kg and 74 kg; the tests were terminated on days 30 and 39, respectively, without any malfunction. The mean aortic pressure, bypass flow, and power consumption for the first calf were maintained at 90 x 13 mmHg, 3.9 x 0.9 l/min, and 12 x 1 W, and those for the second calf were maintained at 88 x 13 mmHg, 5.0 x 0.5 l/min, and 16 x 2 W, respectively. These results indicate that the newly developed drive unit may be used as a wearable pneumatic drive unit for the Toyobo VAD blood pump.
Pressurized thermal shock evaluation of the Calvert Cliffs Unit 1 Nuclear Power Plant
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abbott, L
1985-09-01
An evaluation of the risk to the Calvert Cliffs Unit 1 nuclear power plant due to pressurized thermal shock (PTS) has been completed by Oak Ridge National Laboratory (ORNL) with the assistance of several other organizations. This evaluation was part of a Nuclear Regulatory Commission program designed to study the PTS risk to three nuclear plants, the other two plants being Oconee Unit 1 and H.B. Robinson Unit 2. The specific objectives of the program were to (1) provide a best estimate of the frequency of a through-the-wall crack in the pressure vessel at each of the three plants, togethermore » with the uncertainty in the estimated frequency and its sensitivity to the variables used in the evaluation; (2) determine the dominant overcooling sequences contributing to the estimated frequency and the associated failures in the plant systems or in operator actions; and (3) evaluate the effectiveness of potential corrective measures.« less
Equations for the determination of humidity from dewpoint and psychrometric data
NASA Technical Reports Server (NTRS)
Parish, O. O.; Putnam, T. W.
1977-01-01
A general expression based on the Claperon-Clausius differential equation that relates saturation vapor pressure, absolute temperature, and the latent heat of transformation was derived that expresses saturation vapor pressure as a function of absolute temperature. This expression was then used to derive general expressions for vapor pressure, absolute humidity, and relative humidity as functions of either dewpoint and ambient temperature or psychrometric parameters. Constants for all general expressions were then evaluated to give specific expressions in both the international system of units and U.S. customary units for temperatures above and below freezing.
Thio, C L; Smith, D; Merz, W G; Streifel, A J; Bova, G; Gay, L; Miller, C B; Perl, T M
2000-01-01
To investigate an outbreak of aspergillosis in a leukemia and bone marrow transplant (BMT) unit and to improve environmental assessment strategies to detect Aspergillus. Epidemiological investigation and detailed environmental assessment. A tertiary-care university hospital with a 37-bed leukemia and BMT unit Leukemic or BMT patients with invasive aspergillosis identified through prospective surveillance and confirmed by chart review. We verified the diagnosis of invasive fungal infection by reviewing medical charts of at-risk patients, performing a case-control study to determine risk factors for infection, instituting wet mopping to clean all floors, providing N95 masks to protect patients outside high-efficiency particulate air (HEPA)-filtered areas, altering traffic patterns into the unit, and performing molecular typing of selected Aspergillus flavus isolates. To assess the environment, we verified pressure relationships between the rooms and hallway and between buildings, and we compared the ability of large-volume (1,200 L) and small-volume (160 L) air samplers to detect Aspergillus spores. Of 29 potential invasive aspergillosis cases, 21 were confirmed by medical chart review. Risk factors for developing invasive aspergillosis included the length of time since malignancy was diagnosed (odds ratio [OR], 1.0; P=.05) and hospitalization in a patient room located near a stairwell door (OR, 3.7; P=.05). Two of five A. flavus patient isolates were identical to one of the environmental isolates. The pressure in most of the rooms was higher than in the corridors, but the pressure in the oncology unit was negative with respect to the physically adjacent hospital; consequently, the unit acted essentially as a vacuum that siphoned non-HEPA-filtered air from the main hospital. Of the 78 samples obtained with a small-volume air sampler, none grew an Aspergillus species, whereas 10 of 40 cultures obtained with a large-volume air sampler did. During active construction, Aspergillus spores may have entered the oncology unit from the physically adjacent hospital because the air pressure differed. Guidelines that establish the minimum acceptable pressures and specify which pressure relationships to test in healthcare settings are needed. Our data show that large-volume air samples are superior to small-volume samples to assess for Aspergillus in the healthcare environment.
Underpressure in Mesozoic and Paleozoic rock units in the Midcontinent of the United States
Nelson, Philip H.; Gianoutsos, Nicholas J.; Drake, Ronald
2015-01-01
Potentiometric surfaces for Paleozoic strata, based on water well levels and selected drill-stem tests, reveal the control on hydraulic head exerted by outcrops in eastern Kansas and Oklahoma. From outcrop in the east, the westward climb of hydraulic head is much less than that of the land surface, with heads falling so far below land surface that the pressure:depth ratio in eastern Colorado is less than 5.7 kPa/m (0.25 psi/ft). Permian evaporites separate the Paleozoic hydrogeologic units from a Lower Cretaceous (Dakota Group) aquifer, and a highly saline brine plume pervading Paleozoic units in central Kansas and Oklahoma is attributed to dissolution of Permian halite. Underpressure also exists in the Lower Cretaceous hydrogeologic unit in the Denver Basin, which is hydrologically separate from the Paleozoic units. The data used to construct the seven potentiometric surfaces were also used to construct seven maps of pressure:depth ratio. These latter maps are a function of the differences among hydraulic head, land-surface elevation, and formation elevation. As a consequence, maps of pressure:depth ratio reflect the interplay of three topologies that evolved independently with time. As underpressure developed, gas migrated in response to the changing pressure regime, most notably filling the Hugoton gas field in southwestern Kansas. The timing of underpressure development was determined by the timing of outcrop exposure and tilting of the Great Plains. Explorationists in western Kansas and eastern Colorado should not be surprised if a reservoir is underpressured; rather, they should be surprised if it is not.
System International d'Unites: Metric Measurement in Water Resources Engineering.
ERIC Educational Resources Information Center
Klingeman, Peter C.
This pamphlet gives definitions and symbols for the basic and derived metric units, prefixes, and conversion factors for units frequently used in water resources. Included are conversion factors for units of area, work, heat, power, pressure, viscosity, flow rate, and others. (BB)
Männistö, Tuija; Liu, Danping; Leishear, Kira; Sherman, Seth; Laughon, S. Katherine
2015-01-01
BACKGROUND Chronic air pollution exposure increases risk for hypertensive disorders of pregnancy, but the effect of acute air pollution exposure on blood pressure during pregnancy is less well known. METHODS We studied 151,276 singleton term deliveries from the Consortium on Safe Labor (2002–2008) with clinical blood pressure measured at admission to labor/delivery and diagnoses of hypertensive disorders collected from electronic medical records and hospital discharge summaries. Air pollution exposures were estimated for the admission hour and the 4 hours preceding admission using a modified version of the Community Multiscale Air Quality models and observed air monitoring data. Blood pressure was categorized as normal; high normal; and mild, moderate, or severe hypertension based on pregnancy cut points. Adjusted ordinal logistic regression estimated the odds of women having a higher admission blood pressure category as a function of air pollutant, hypertensive disorders, and their interaction effect. RESULTS Odds of high blood pressure at admission to labor/delivery were increased in normotensive women after exposure to nitrogen oxides (by 0.2%/5 units), sulfur dioxide (by 0.3%/1 unit), carbon monoxide and several air toxics (by 3%–4%/high exposure). The effects were often similar or stronger among women with gestational hypertension and preeclampsia. Exposure to particulate matter <10 μm increased odds of high blood pressure in women with preeclampsia by 3%/5 units. CONCLUSIONS Air pollution can influence admission blood pressure in term deliveries and may increase likelihood of preeclampsia screening at delivery admission. PMID:24795401
[Trends in the prevalence of pressure ulcers in an acute care tertiary hospital (2006-2013)].
Alonso-Lorente, C; Barrasa-Villar, J I; Aibar-Remón, C
2015-01-01
To analyse the trends in pressure ulcer prevalence from 2006 to 2013. To determine the main risk factors associated with pressure ulcers. A descriptive study analysing the prevalence in a series of pressure ulcers collected in the study on the prevalence of nosocomial infections in Spain from 2006 to 2013 in the Clinical University Hospital of Zaragoza. The mean prevalence among the 5,354 patients included over the period of study was 4.5% (95% CI=3.9-5.0%). No significant difference in its trend or distribution of pressure ulcers was observed over the several years of the study. Prevalence increased up to 5.0% (95% CI=4.4-5.6%) when short-stay patients (less than 24 hours) and those admitted into low risk units (Paediatrics, Psychiatry and Obstetrics) were removed from the study, but there was still no significant differences in its yearly trend or distribution (p>0.05). Age, length of stay, presence of coma, in-dwelling urethral catheters, malnutrition, infection, and admission unit were risk factors associated with pressure ulcer prevalence in the logistic regression. Age, length of stay, coma, in-dwelling urethral catheters, malnutrition, infection, and admission unit were independent risk markers for patients with pressure ulcers. No particular trend of pressure ulcer prevalence could be determined to demonstrate any effects from the different strategies of improvement implemented during the period of study, although this fact could be due to the limitations of data used in the study. Copyright © 2014 SECA. Published by Elsevier Espana. All rights reserved.
Rowe, Angela D; McCarty, Karen; Huett, Amy
2018-03-13
A large, freestanding pediatric hospital in the southern United States saw a 117% increase in reported hospital acquired pressure injuries (HAPI) between 2013 and 2015, with the intensive care units being the units of highest occurrence. Design and Methods A quality improvement project was designed and implemented to assist with pressure injury prevention. Literature review confirmed that pediatric HAPIs are a challenge and that usage of bundles and user-friendly guidelines/pathways can help eliminate barriers to prevention. The aim of this quality improvement project had two aims. First, to reduce HAPI incidence in the PICU by 10%. Second, to increase consistent usage of pressure injury prevention strategies as evidenced by a 10% increase in pressure injury bundle compliance. The third aim was to identify if there are differences in percentage of interventions implemented between two different groups of patients. Donabedian's model of Structure, Process, and Outcomes guided the development and implementation of this quality improvement project. Interventions focused on risk assessment subscale scores have the opportunity to mitigate specific risk factors and improve pressure injury prevention. Through implementation of the nurse driven pathway there was as 57% decrease in reported HAPIs in the PICU as well as a 66% increase in pressure ulcer prevention bundle compliance. Implementation of the nurse driven pressure injury prevention pathway was successful. There was a significant increase in bundle compliance for pressure ulcer prevention and a decrease in reported HAPIs. The pathway developed and implemented for this quality improvement project could be adapted to other populations and care settings to provide guidance across the continuum. Copyright © 2018 Elsevier Inc. All rights reserved.
Heating equipment installation system
Meuschke, Robert E.; Pomaibo, Paul P.
1991-01-01
A method for installing a heater unit assembly (52, 54) in a reactor pressure vessel (2) for performance of an annealing treatment on the vessel (2), the vessel (2) having a vertical axis, being open at the top, being provided at the top with a flange (6) having a horizontal surface, and being provided internally, at a location below the flange (6), with orientation elements (8) which are asymmetrical with respect to the vertical axis, by the steps of: providing an orientation fixture (10) having an upwardly extending guide member (18) and orientation elements (14, 16) and installing the orientation fixture (10) in the vessel (2) so that the orientation elements (14,16) of the orientation fixture (10) mate with the orientation elements (8) of the pressure vessel (2) in order to establish a defined position of the orientation fixture (10) in the pressure vessel (2), and so that the guide member (18) projects above the pressure vessel (2) flange (6); placing a seal ring (30) in a defined position on the pressure vessel (2) flange (6) with the aid of the guide member (18); mounting at least one vertical, upwardly extending guide stud (40) upon the seal ring (30); withdrawing the orientation fixture (10) from the pressure vessel (2); and moving the heater unit assembly (52,54) vertically downwardly into the pressure vessel (2) while guiding the heater unit assembly (52,54) along a path with the aid of the guide stud (40).
Modrykamien, Ariel M; Daoud, Yahya
2018-01-01
Optimal mechanical ventilation management in patients with the acute respiratory distress syndrome (ARDS) involves the use of low tidal volumes and limited plateau pressure. Refractory hypoxemia may not respond to this strategy, requiring other interventions. The use of prone positioning in severe ARDS resulted in improvement in 28-day survival. To determine whether mechanical ventilation strategies or other parameters affected survival in patients undergoing prone positioning, a retrospective analysis was conducted of a consecutive series of patients with severe ARDS treated with prone positioning. Demographic and clinical information involving mechanical ventilation strategies, as well as other variables associated with prone positioning, was collected. The rate of in-hospital mortality was obtained, and previously described parameters were compared between survivors and nonsurvivors. Forty-three patients with severe ARDS were treated with prone positioning, and 27 (63%) died in the intensive care unit. Only three parameters were significant predictors of survival: APACHE II score ( P = 0.03), plateau pressure ( P = 0.02), and driving pressure ( P = 0.04). The ability of each of these parameters to predict mortality was assessed with receiver operating characteristic curves. The area under the curve values for APACHE II, plateau pressure, and driving pressure were 0.74, 0.69, and 0.67, respectively. In conclusion, in a group of patients with severe ARDS treated with prone positioning, only APACHE II, plateau pressure, and driving pressure were associated with mortality in the intensive care unit.
Improved fireman's compressed air breathing system pressure vessel development program
NASA Technical Reports Server (NTRS)
King, H. A.; Morris, E. E.
1973-01-01
Prototype high pressure glass filament-wound, aluminum-lined pressurant vessels suitable for use in a fireman's compressed air breathing system were designed, fabricated, and acceptance tested in order to demonstrate the feasibility of producing such high performance, lightweight units. The 4000 psi tanks have a 60 standard cubic foot (SCF) air capacity, and have a 6.5 inch diamter, 19 inch length, 415 inch volume, weigh 13 pounds when empty, and contain 33 percent more air than the current 45 SCF (2250 psi) steel units. The current steel 60 SCF (3000 psi) tanks weigh approximately twice as much as the prototype when empty, and are 2 inches, or 10 percent shorter. The prototype units also have non-rusting aluminum interiors, which removes the hazard of corrosion, the need for internal coatings, and the possibility of rust particles clogging the breathing system.
Loss of control air at Browns Ferry Unit One: accident sequence analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harrington, R.M.; Hodge, S.A.
1986-04-01
This study describes the predicted response of the Browns Ferry Nuclear Plant to a postulated complete failure of plant control air. The failure of plant control air cascades to include the loss of drywell control air at Units 1 and 2. Nevertheless, this is a benign accident unless compounded by simultaneous failures in the turbine-driven high pressure injection systems. Accident sequence calculations are presented for Loss of Control Air sequences with assumed failure upon demand of the Reactor Core Isolation Cooling (RCIC) and the High Pressure Coolant Injection (HPCI) at Unit 1. Sequences with and without operator action are considered.more » Results show that the operators can prevent core uncovery if they take action to utilize the Control Rod Drive Hydraulic System as a backup high pressure injection system.« less
77 FR 16430 - Airworthiness Directives; Airbus Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-21
... opposite the line replaceable unit racking. This AD requires replacing a certain aluminum high pressure... proposed to require replacing a certain aluminum high pressure pipe with a new corrosion resistant... comply with paragraph (1) of this [EASA] AD, unless, inadvertently, the high pressure pipe P/N...
Detonation Characteristics of Some Dusts and Liquid-Dust Suspensions
1983-07-01
instrumentation which includes pressure switches, pressure transducers, a photodiode, and streak photography. The pressure switch , which is a mechanical on/ off...camera through a lens. The Xenon light is triggered by the pressure switch located upstream of the window section. A time delay device is used in...conjunction with the pressure switch and the light source power supply. When the pressure switch is swept by the shock wave, a signal is sent to the delay unit
An electronic scanner of pressure for wind tunnel models
NASA Technical Reports Server (NTRS)
Kauffman, Ronald C.; Coe, Charles F.
1986-01-01
An electronic scanner of pressure (ESOP) has been developed by NASA Ames Research Center for installation in wind tunnel models. An ESOP system consists of up to 20 pressure modules (PMs), each with 48 pressure transducers and a heater, an analog-to-digital (A/D) converter module, a microprocessor, a data controller, a monitor unit, a control and processing unit, and a heater controller. The PMs and the A/D converter module are sized to be installed in the models tested in the Ames Aerodynamics Division wind tunnels. A unique feature of the pressure module is the lack of moving parts such as a pneumatic switch used in other systems for in situ calibrations. This paper describes the ESOP system and the results of the initial testing of the system. The initial results indicate the system meets the original design goal of 0.15 percent accuracy.
Experimental Investigation and Numerical Predication of a Cross-Flow Fan
2006-12-01
Figure 3. Combination probes and pressure tap layout .....................................................6 Figure 4. CFF_DAQ graphical user interface...properties were United Sensor Devices model USD-C-161 3 mm (1/8-inch) combination thermocouple/pressure probes, and static pressure taps . The...was applied to the three static pressure tapes at the throat of the bell-mouth and to the two exhaust duct static pressure taps . Once the data
Investigation of Shallow Undex in Littoral Ocean Domain
2014-06-01
pPos Units=Pa #Units: psi, ksi, Pa, MPa, bar or scaling factor # Var=pNeg Units=Pa #Units: psi, ksi, Pa, MPa...net) # i = Impulse intensity (time in sec) # ppos = Element pressure on "positive" side (normal points toward "eye") of coupling interface
Assessment of Energy Storage Technologies for Army Facilities.
1986-05-01
units, and the other on tandem units with separate multistage pump and Pelton impulse turbine . The third scheme was a double-drop type based on the...used to drive the turbine /generator. Exhaust gas from the low-pressure turbine may be used to preheat inlet air to the high-pressure turbine . Storage...for firing CAES plant turbines . A Battelle publication summarizes reservoir stability criteria and research directed toward minimizing or eliminating
Environmental Assessment: Installation Development at Vance Air Force Base, Oklahoma
2007-04-01
intensity, frequency, and duration. Sound is created by acoustic energy, which produces minute pressure waves that travel through a medium, like...acoustic energy increases, the intensity or amplitude of these pressure waves increase, and the ear senses louder noise. The unit used to measure the...shale, siltstone, sandstone, limestone, and dolomite ranging in age from Cambrian-Ordovician through Permian. These sedimentary units rest upon the Pre
NASA Astrophysics Data System (ADS)
Manzotti, Paola; Bosse, Valérie; Pitra, Pavel; Robyr, Martin; Schiavi, Federica; Ballèvre, Michel
2018-03-01
Exhumation rates for high-pressure metamorphic rocks need to be carefully estimated to decipher tectonic processes in subduction/collision belts. In the Gran Paradiso Massif (Western Alps), the Money Unit crops out as a tectonic window below the Gran Paradiso Unit. According to previous studies, the Gran Paradiso and Money Units reached peak pressure conditions at 18 to 20 kbar, 480-520 °C and 17 to 18 kbar, 500-550 °C, respectively. This yields a maximum difference of 9 to 10 km in the subduction depth reached by these two units during the Alpine history. Thrusting of the Gran Paradiso Unit over the Money Unit led to the simultaneous development of the main foliation under the same metamorphic conditions ( 12.5 to 14.5 kbar and 530-560 °C) in both units. The thrust contact was subsequently folded and then both units were exhumed together. The relative timing of the growth and dissolution of the accessory phases was assessed by combining thermodynamic modelling with inclusion, textural and chemical (major and trace element) data from both major and accessory phases. The age of monazite constrained the high-pressure metamorphism in both the Gran Paradiso Unit and the Money Unit at 41.5 ± 0.3 and 42.0 ± 0.6 Ma, respectively. Allanite replacing monazite in the matrix has been dated at 32.7 ± 4.2 Ma. The late growth of xenotime associated with the crystallization of biotite pseudomorphs at the expense of garnet (at about 10 kbar) was dated at 32.3 ± 1.0 Ma. Our petrochronological data indicate about 10 m.y. between the peak pressure conditions and the crystallization of xenotime leading to an exhumation rate of the order of 2.2-5 mm/year. The new ages allow to better constrain the timing of the displacement of the thrust defining the lower boundary of the extruding wedge of eclogite-facies rocks.
A Spatially Explicit Method for Prioritizing AIS Surveillance ...
Choosing where to sample for aquatic invasive species (AIS) is a daunting challenge in the Laurentian Great Lakes. Management resources are finite hence it is important that monitoring efforts concentrate on those sites with the highest risk of introduction based on transparent criteria and assumptions and the best available data. Here we describe the development of a site prioritization method designed to address such challenges. The U.S. waters of the Great Lakes and tributaries were divided into standardized management units (9 km x 9 km). An index of invasion pressure was defined using a standardized set of spatial surrogates to estimate cumulative propagule pressure for each management unit. Weighting multipliers were applied to the attributed spatial surrogate data so that both historic patterns and future predicted patterns of introduction were incorporated into the final calculation of the index of invasion pressure for each management unit. Of the total of 5,953 management units in the U.S. Great Lakes basin (land and water), about 1,800 units have attributes resulting in index scores greater than zero. The site prioritization method can be used to select surveillance priorities for fish, invertebrates, and/or plants across the U.S. waters of the Great Lakes basin. not applicable
Study on safety operation for large hydroelectric generator unit
NASA Astrophysics Data System (ADS)
Yan, Z. G.; Cui, T.; Zhou, L. J.; Zhi, F. L.; Wang, Z. W.
2012-11-01
Hydroelectric generator unit is a complex mechanical system which is composed of hydraulic turbine and electric generator. Rotary system is supported by the bearing bracket and the reinforced concrete structures, and vibration problem can't be avoided in the process of operating. Many large-scale hydroelectric units have been damaged because of the vibration problem in recent years. As the increase of the hydraulic turbine unit capacity and water head, the safe operation of hydraulic turbine has become a focus research in many countries. The operating characteristics of the hydraulic turbine have obvious differences at different working conditions. Based on the combination of field measurement and theoretical calculation, this paper shows a deep research on the safe operation of a large-scale Francis turbine unit. Firstly, the measurements of vibration, swing, pressure fluctuation and noise were carried out at 4 different heads. And also the relationships between vibrations and pressure fluctuations at different heads and working conditions were analysed deeply. Then the scientific prediction of safe operation for the unit at high head were done based on the CFD numerical calculation. Finally, this paper shows the division of the operating zone for the hydroelectric unit. According to the experimental results (vibrations, swings, pressure fluctuations and noise) as well as the theoretical results, the operating zone of the unit has been divided into three sections: prohibited operating zone, transition operating zone and safe operating zone. After this research was applied in the hydropower station, the security and economic efficiency of unit increased greatly, and enormous economic benefits and social benefits have been obtained.
46 CFR 58.60-3 - Pressure vessel.
Code of Federal Regulations, 2013 CFR
2013-10-01
... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MAIN AND AUXILIARY MACHINERY AND RELATED SYSTEMS Industrial Systems and Components on Mobile Offshore Drilling Units (MODU) § 58.60-3 Pressure vessel. A pressure vessel that is a component in an industrial system under this subpart must meet...
46 CFR 58.60-3 - Pressure vessel.
Code of Federal Regulations, 2010 CFR
2010-10-01
... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MAIN AND AUXILIARY MACHINERY AND RELATED SYSTEMS Industrial Systems and Components on Mobile Offshore Drilling Units (MODU) § 58.60-3 Pressure vessel. A pressure vessel that is a component in an industrial system under this subpart must meet...
46 CFR 58.60-3 - Pressure vessel.
Code of Federal Regulations, 2012 CFR
2012-10-01
... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MAIN AND AUXILIARY MACHINERY AND RELATED SYSTEMS Industrial Systems and Components on Mobile Offshore Drilling Units (MODU) § 58.60-3 Pressure vessel. A pressure vessel that is a component in an industrial system under this subpart must meet...
46 CFR 58.60-3 - Pressure vessel.
Code of Federal Regulations, 2014 CFR
2014-10-01
... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MAIN AND AUXILIARY MACHINERY AND RELATED SYSTEMS Industrial Systems and Components on Mobile Offshore Drilling Units (MODU) § 58.60-3 Pressure vessel. A pressure vessel that is a component in an industrial system under this subpart must meet...
46 CFR 58.60-3 - Pressure vessel.
Code of Federal Regulations, 2011 CFR
2011-10-01
... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MAIN AND AUXILIARY MACHINERY AND RELATED SYSTEMS Industrial Systems and Components on Mobile Offshore Drilling Units (MODU) § 58.60-3 Pressure vessel. A pressure vessel that is a component in an industrial system under this subpart must meet...
Hand-Held Self-Maneuvering Unit to be used during EVA on Gemini 4
1965-06-02
Hand-Held Self-Maneuvering Unit to be used during extravehicular activity (EVA) on Gemini 4 flight. It is an integral unit that contains its own high pressure metering valves and nozzles required to produce controlled thrust. A camera is mounted on the front of the unit.
[An assessment scale for the prevention of pressure sores in children].
Chauvet, Corinne; Poirier, Marie-Renée; Sourisseau, Petronela Rachieru; Béduneau, Denis; Soulard, Anthony; Delacroix, Delphine
2015-04-01
Pressure sores in children are rare. However, when they do occur they can have significant consequences. Professionals in paediatric units realised the importance of assessing the risk of pressure sores and developed a pressure sore assessment scale specific to children. This project, carried out through a hospital-training school partnership, emphasises the importance of clinical reasoning in nursing practices.
NASA Astrophysics Data System (ADS)
1990-01-01
System 8400 is an advanced system for measurement of gas and liquid pressure, along with a variety of other parameters, including voltage, frequency and digital inputs. System 8400 offers exceptionally high speed data acquisition through parallel processing, and its modular design allows expansion from a relatively inexpensive entry level system by the addition of modular Input Units that can be installed or removed in minutes. Douglas Juanarena was on the team of engineers that developed a new technology known as ESP (electronically scanned pressure). The Langley ESP measurement system was based on miniature integrated circuit pressure-sensing transducers that communicated pressure information to a minicomputer. In 1977, Juanarena formed PSI to exploit the NASA technology. In 1978 he left Langley, obtained a NASA license for the technology, introduced the first commercial product, the 780B pressure measurement system. PSI developed a pressure scanner for automation of industrial processes. Now in its second design generation, the DPT-6400 is capable of making 2,000 measurements a second and has 64 channels by addition of slave units. New system 8400 represents PSI's bid to further exploit the 600 million U.S. industrial pressure measurement market. It is geared to provide a turnkey solution to physical measurement.
Ferreira, Lucas Lima; Valenti, Vitor Engrácia; Vanderlei, Luiz Carlos Marques
2013-01-01
Objective To analyze the outcomes of increased or decreased intracranial pressure and/or the decrease in cerebral perfusion pressure resulting from respiratory physiotherapy on critically ill patients admitted to the intensive care unit. Methods Through a systematic review of the literature, clinical trials published between 2002 and 2012 were selected. The search involved the LILACS, SciELO, MedLine and PEDro databases using the keywords "physical therapy", "physiotherapy", "respiratory therapy" and "randomized controlled trials" combined with the keyword "intracranial pressure". Results In total, five studies, including a total of 164 patients between 25 and 65 years of age, reporting that respiratory physiotherapy maneuvers significantly increased intracranial pressure without changing the cerebral perfusion pressure were included. The articles addressed several techniques including vibration, vibrocompression, tapping, postural drainage, and the endotracheal aspiration maneuver. All patients required invasive mechanical ventilation. Conclusion Respiratory physiotherapy leads to increased intracranial pressure. Studies suggest that there are no short-term hemodynamic or respiratory repercussions or changes in the cerebral perfusion pressure. However, none of the studies evaluated the clinical outcomes or ensured the safety of the maneuvers. PMID:24553515
Performance Charts for a Turbojet System
NASA Technical Reports Server (NTRS)
Karp, Irving M.
1947-01-01
Convenient charts are presented for computing the thrust, fuel consumption, and other performance values of a turbojet system. These charts take into account the effects of ram pressure, compressor pressure ratio, ratio of combustion-chamber-outlet temperature to atmospheric temperature, compressor efficiency, turbine efficiency, combustion efficiency, discharge-nozzle coefficient, losses in total pressure in the inlet to the jet-propulsion unit and in the combustion chamber, and variation in specific heats with temperature. The principal performance charts show clearly the effects of the primary variables and correction charts provide the effects of the secondary variables. The performance of illustrative cases of turbojet systems is given. It is shown that maximum thrust per unit mass rate of air flow occurs at a lower compressor pressure ratio than minimum specific fuel consumption. The thrust per unit mass rate of air flow increases as the combustion-chamber discharge temperature increases. For minimum specific fuel consumption, however, an optimum combustion-chamber discharge temperature exists, which in some cases may be less than the limiting temperature imposed by the strength temperature characteristics of present materials.
Development of a 30mm Frangible Projectile Crimper
1977-02-01
located at end of tank. Open drain valve to drain condensation Tht outomatic lank drain equipped compressor makes this unnecessary. PRESSURE SWITCH : The... pressure switch is automatic and will start compressor at the low pressure and stop when the maximum pressure is leached. It is adjusted to start...of the check valve, located between the compressor and the tank, together with the relief valve on pressure switch relief valve units, and the cen
Population Pressures Abroad and Immigration Pressures at Home.
ERIC Educational Resources Information Center
Population Crisis Committee, Washington, DC.
This report discusses population trends abroad and their relation to immigration pressures and policies in the United States. The following sections are included: (1) "Two Major Waves of Immigration"; (2) "The U.S.--A Major Host Nation for Permanent Immigrants"; (3) "Changing Sources of Immigrants to the United…
77 FR 37712 - High Pressure Steel Cylinders From China
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-22
... Pressure Steel Cylinders From China Determinations On the basis of the record \\1\\ developed in the subject... cylinders from China, provided for in subheading 7311.00.00 of the Harmonized Tariff Schedule of the United... preliminary determinations by Commerce that imports of high pressure steel cylinders from China were...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-18
... the United States is materially retarded, by reason of imports from China of High Pressure Steel... INTERNATIONAL TRADE COMMISSION [Investigation Nos. 701-TA-480 and 731-TA-1188 (Preliminary)] High Pressure Steel Cylinders From China; Institution of Antidumping and Countervailing Duty Investigations and...
NASA Astrophysics Data System (ADS)
Dekterev, D.; Maslennikova, A.; Abramov, A.
2017-09-01
The operation modes of the hydraulic power plant water turbine with the formation of a precessing vortex core were studied on the hydrodynamic set-up with the model of hydraulic unit. The dependence of low-frequency vibrations on flow pressure pulsations in the hydraulic unit was established. The results of the air injection effect on the vibrational parameters of the hydrodynamic set-up were presented.
Männistö, Tuija; Mendola, Pauline; Liu, Danping; Leishear, Kira; Sherman, Seth; Laughon, S Katherine
2015-01-01
Chronic air pollution exposure increases risk for hypertensive disorders of pregnancy, but the effect of acute air pollution exposure on blood pressure during pregnancy is less well known. We studied 151,276 singleton term deliveries from the Consortium on Safe Labor (2002-2008) with clinical blood pressure measured at admission to labor/delivery and diagnoses of hypertensive disorders collected from electronic medical records and hospital discharge summaries. Air pollution exposures were estimated for the admission hour and the 4 hours preceding admission using a modified version of the Community Multiscale Air Quality models and observed air monitoring data. Blood pressure was categorized as normal; high normal; and mild, moderate, or severe hypertension based on pregnancy cut points. Adjusted ordinal logistic regression estimated the odds of women having a higher admission blood pressure category as a function of air pollutant, hypertensive disorders, and their interaction effect. Odds of high blood pressure at admission to labor/delivery were increased in normotensive women after exposure to nitrogen oxides (by 0.2%/5 units), sulfur dioxide (by 0.3%/1 unit), carbon monoxide and several air toxics (by 3%-4%/high exposure). The effects were often similar or stronger among women with gestational hypertension and preeclampsia. Exposure to particulate matter <10 μm increased odds of high blood pressure in women with preeclampsia by 3%/5 units. Air pollution can influence admission blood pressure in term deliveries and may increase likelihood of preeclampsia screening at delivery admission. © Published by Oxford University Press on behalf of American Journal of Hypertension Ltd 2014. This work is written by (a) US Government employees(s) and is in the public domain in the US.
Temperature and pressure dependent thermodynamic behavior of 2H-CuInO2
NASA Astrophysics Data System (ADS)
Bhamu, K. C.
2018-05-01
Density functional theory and quasi-harmonic Debye model has been used to study the thermodynamic properties of 2H-CuInO2. At the optimized structural parameters, pressure (0 to 80 GPa) dependent variation in the various thermodynamic properties, i.e. unit cell volume (V), bulk modulus (B), specific heat (Cv), Debye temperature (θD), Grüneisen parameter (γ) and thermal expansion coefficient (α) are calculated for various temperature values. The results predict that the pressure has significant effect on unit cell volume and bulk modulus while the temperature shows negligible effect on both parameters. With increasing temperature thermal expansion coefficient increase while with increasing pressure it decreases. The specific heat remains close to zero for ambient pressure and temperature values and it increases with increasing temperature. It is observed that the pressure has high impact on Debye temperature and Grüneisen parameter instead of temperature. Debye temperature and Grüneisen parameter both remains almost constant for the temperature range (0-300K) while Grüneisen parameter decrease with increasing pressure at constant temperature and Debye temperature increases rapidly with increasing pressure. An increase in Debye temperature with respect to pressure shows that the thermal vibration frequency changes rapidly.
Çelik, Sevim; Yildirim, Ismail; Arslan, Ibrahim; Yildirim, Sinan; Erdal, Fatih; Yandi, Yunus Emre
2011-12-01
The purpose of this study was to determine the effects of fever and nursing interventions to lower fever on hemodynamic values and oxygenation in febrile (temperature greater than 38.3°C) surgical intensive care unit patients. This retrospective study was conducted in 53 febrile patients out of 519 patients admitted to the surgical intensive care unit at a university hospital. Data were obtained from the medical records, laboratory files and nursing notes. Statistical analysis of the data was analyzed by repeated measures analysis of variance and a paired sample t-test. The average hourly urine output (F = 5.46; P = 0.002) and systolic blood pressure (F = 2.87; P = 0.03) were significantly lower after fever onset. Heart rate, respiratory rate, positive end-expiratory pressure settings and FiO(2) settings were unchanged after the development of fever. Diastolic blood pressure and oxygen saturation had non-statistically significant decreases. Nursing interventions for febrile patients consisted of medication administration (69.8%), ice (62.3%) and sponging with tepid water (62.3%). The present results showed that fever was associated with an increase in heart rate, decreased systolic arterial pressure, mean arterial pressure, oxygen saturation and hourly urine output. © 2011 Blackwell Publishing Asia Pty Ltd.
Refuge alternatives relief valve testing and design
Lutz, T.J.; Bissert, P.T.; Homce, G.T.; Yonkey, J.A.
2016-01-01
The U.S. National Institute for Occupational Safety and Health (NIOSH) has been researching refuge alternatives (RAs) since 2007. RAs typically have built-in pressure relief valves (PRVs) to prevent the unit from reaching unsafe pressures. The U.S. Mine Safety and Health Administration requires that these valves vent the chamber at a maximum pressure of 1.25 kPa (0.18 psi, 5.0 in. H2O), or as specified by the manufacturer, above mine atmospheric pressure in the RA. To facilitate PRV testing, an instrumented benchtop test fixture was developed using an off-the-shelf centrifugal blower and ductwork. Relief pressures and flow characteristics were measured for three units: (1) a modified polyvinyl chloride check valve, (2) an off-the-shelf brass/cast-iron butterfly check valve and (3) a commercially available valve that was designed specifically for one manufacturer’s steel prefabricated RAs and had been adapted for use in one mine operator’s built-in-place RA. PRVs used in tent-style RAs were not investigated. The units were tested with different modifications and configurations in order to check compliance with Title 30 Code of Federal Regulations, or 30 CFR, regulations. The commercially available relief valve did not meet the 30 CFR relief pressure specification but may meet the manufacturer’s specification. Alternative valve designs were modified to meet the 30 CFR relief pressure specification, but all valve designs will need further design research to examine survivability in the event of a 103 kPa (15.0 psi) impulse overpressure during a disaster. PMID:28018003
Development Specification for RV-346/348 Positive Pressure Relief Valves (PPRV)
NASA Technical Reports Server (NTRS)
Ralston, Russell L.
2017-01-01
This specification establishes the requirements for design, performance, safety, testing, and manufacture of the RV-346 and RV-348, Positive Pressure Relief Valve (PPRV) as part of the Advanced Extravehicular Mobility Unit (EMU)(AEMU) Portable Life Support System (PLSS). The RV-346 serves as the Positive Pressure Relief Valve (PPRV), and the RV-348 serves as the Secondary Positive Pressure Relief Valve (SPPRV).
Coyer, Fiona; Miles, Sandra; Gosley, Sandra; Fulbrook, Paul; Sketcher-Baker, Kirstine; Cook, Jane-Louise; Whitmore, Jacqueline
2017-09-01
Hospital-acquired pressure injury is associated with increased morbidity and mortality and considered to be largely preventable. Pressure injury prevalence is regarded as a marker of health care quality. To compare the state-wide prevalence, severity and location of pressure injuries of intensive care unit patients compared to patients in non-intensive care wards. The study employed a secondary data analysis design to extract and analyse de-identified pressure injury data from all Queensland Health hospitals with level I-III intensive care facilities that participated in Queensland Bedside Audits between 2012-2014. The sample included all adult ICU and non-ICU patients that provided consent for the Queensland Bedside Audits, excluding those in mental health units. Excluding Stage I, overall hospital-acquired pressure injury prevalence from 2012 to 2014 was 11% for intensive care patients and 3% for non-intensive care patients. Intensive care patients were 3.8 times more likely (RR 2.7-5.4, 95% CI) than non-intensive care patients to develop a pressure injury whilst in hospital. The sacrum/coccyx was the most common site of hospital-acquired pressure injury in all patients (intensive care patients 22%; non-intensive care patients 35%) however, mucosal pressure injury proportion was significantly higher in intensive care patients (22%) than in non-intensive care patients (2%). Stage II HAPI prevalence was the most common stage reported, 53% for intensive care patients compared to 63% for non-intensive care patients. There are significant differences in hospital-acquired pressure injury prevalence by stage and location between intensive care and non-intensive care patients reflecting the possible impact of critical illness on the development of skin injury. This has implications for resource funding for pressure injury prevention and the imposition of government initiated financial penalties for hospital-acquired pressure injury. For future comparisons to be effective between intensive care units, benchmarking partners should share similar characteristics and relevant targets. Copyright © 2016 Australian College of Critical Care Nurses Ltd. All rights reserved.
Burke, S L; Dorward, P K; Korner, P I
1986-09-01
In both anaesthetized and conscious rabbits, perivascular balloon inflations slowly raised or lowered mean arterial pressure (M.A.P.), at 1-2 mmHg/s, from resting to various plateau pressures. Deflations then returned the M.A.P. to resting. 'Steady-state' curves relating M.A.P. to unitary aortic baroreceptor firing, integrated aortic nerve activity and heart rate were derived during the primary and return pressure changes and they formed typical hysteresis loops. In single units, return M.A.P.-frequency curves were shifted in the same direction as the primary pressure changes by an average 0.37 mmHg per mmHg change in M.A.P. Shifts were linearly related to the changes in M.A.P. between resting and plateau levels for all pressure rises and for falls less than 30 mmHg. They were established within 30 s and were quantitatively similar to the rapid resetting of baroreceptor function curves found 15 min-2 h after a change in resting M.A.P. (Dorward, Andresen, Burke, Oliver & Korner, 1982). Unit threshold pressures were shifted within 20 s to the same extent as the over-all curve shift to which they contributed. In the whole aortic nerve, return M.A.P.-integrated activity curves were shifted to same degree as unit function curves in both anaesthetized and conscious rabbits. Simultaneous shifts of return reflex M.A.P.-heart rate curves were also seen in conscious rabbits within 30 s. During M.A.P. falls, receptor and reflex hysteresis was similar, but during M.A.P. rises, reflex shifts were double baroreceptor shifts, suggesting the involvement of other pressure-sensitive receptors. We conclude that hysteresis shifts in baroreceptor function curves, which follow the reversal of slow ramp changes in blood pressure are a form of rapid resetting. They are accompanied by rapid resetting of reflex heart rate responses. We regard this as an important mechanism in blood pressure control which produces relatively high-gain reflex responses, during slow directional pressure changes, over a wider range of absolute pressure levels than would otherwise be possible.
49 CFR 173.172 - Aircraft hydraulic power unit fuel tank.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 2 2012-10-01 2012-10-01 false Aircraft hydraulic power unit fuel tank. 173.172... Class 1 and Class 7 § 173.172 Aircraft hydraulic power unit fuel tank. Aircraft hydraulic power unit... consist of an aluminum pressure vessel made from tubing and having welded heads. Primary containment of...
49 CFR 173.172 - Aircraft hydraulic power unit fuel tank.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 2 2014-10-01 2014-10-01 false Aircraft hydraulic power unit fuel tank. 173.172... Class 1 and Class 7 § 173.172 Aircraft hydraulic power unit fuel tank. Aircraft hydraulic power unit... consist of an aluminum pressure vessel made from tubing and having welded heads. Primary containment of...
49 CFR 173.172 - Aircraft hydraulic power unit fuel tank.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 2 2011-10-01 2011-10-01 false Aircraft hydraulic power unit fuel tank. 173.172... Class 1 and Class 7 § 173.172 Aircraft hydraulic power unit fuel tank. Aircraft hydraulic power unit... consist of an aluminum pressure vessel made from tubing and having welded heads. Primary containment of...
49 CFR 173.172 - Aircraft hydraulic power unit fuel tank.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 2 2013-10-01 2013-10-01 false Aircraft hydraulic power unit fuel tank. 173.172... Class 1 and Class 7 § 173.172 Aircraft hydraulic power unit fuel tank. Aircraft hydraulic power unit... consist of an aluminum pressure vessel made from tubing and having welded heads. Primary containment of...
49 CFR 173.172 - Aircraft hydraulic power unit fuel tank.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 2 2010-10-01 2010-10-01 false Aircraft hydraulic power unit fuel tank. 173.172... Class 1 and Class 7 § 173.172 Aircraft hydraulic power unit fuel tank. Aircraft hydraulic power unit... consist of an aluminum pressure vessel made from tubing and having welded heads. Primary containment of...
Hobson, Deborah B; Chang, Tracy Y; Aboagye, Jonathan K; Lau, Brandyn D; Shihab, Hasan M; Fisher, Betsy; Young, Samantha; Sujeta, Nancy; Shaffer, Dauryne L; Popoola, Victor O; Kraus, Peggy S; Knorr, Gina; Farrow, Norma E; Streiff, Michael B; Haut, Elliott R
2017-08-01
This study aimed to determine the prevalence of static graduated compression stocking (sGCS)-associated pressure injury among patients in surgical intensive care units (ICUs). We retrospectively reviewed data from wound care rounds between April 2011 and June 2012 at 3 surgical ICUs at an urban, tertiary care hospital. Patients with sGCS-associated pressure injury were identified and descriptive analysis was performed on their demographic, perioperative, and postoperative characteristics. We examined 1787 individual patients during 2391 patient encounters. A total of 129 (7.2%) of patients developed pressure injuries. Forty patients (2.2%) developed sGCS-associated pressure injury. Static GCS-associated pressure injury accounted for 31% (40/129) of all pressure injuries and 74% (40/54) of all medical device-related pressure injury. Eighteen (45%) and 6 (15%) developed stage 1 and 2 pressure injury, respectively, and 16 (40%) developed deep tissue injuries. The mean age of our patients was 64.7 years, about half (47.5%) were male, and their mean Acute Physiology and Chronic Health Evaluation II score was 18.8. Many had comorbid conditions, including obesity (44.5%) and diabetes (42.5%), and required mechanical ventilation (45%). Pressure injuries are a notable complication of sGCS in surgical ICU patients. Appropriate measures are required to help avoid this potentially preventable harm. Copyright © 2017 Elsevier Inc. All rights reserved.
Evaluation of a Progressive Mobility Protocol in Postoperative Cardiothoracic Surgical Patients.
Floyd, Shawn; Craig, Sarah W; Topley, Darla; Tullmann, Dorothy
2016-01-01
Cardiothoracic surgical patients are at high risk for complications related to immobility, such as increased intensive care and hospital length of stay, intensive care unit readmission, pressure ulcer development, and deep vein thrombosis/pulmonary embolus. A progressive mobility protocol was started in the thoracic cardiovascular intensive care unit in a rural academic medical center. The purpose of the progressive mobility protocol was to increase mobilization of postoperative patients and decrease complications related to immobility in this unique patient population. A matched-pairs design was used to compare a randomly selected sample of the preintervention group (n = 30) to a matched postintervention group (n = 30). The analysis compared outcomes including intensive care unit and hospital length of stay, intensive care unit readmission occurrence, pressure ulcer prevalence, and deep vein thrombosis/pulmonary embolism prevalence between the 2 groups. Although this comparison does not achieve statistical significance (P < .05) for any of the outcomes measured, it does show clinical significance in a reduction in hospital length of stay, intensive care unit days, in intensive care unit readmission rate, and a decline in pressure ulcer prevalence, which is the overall goal of progressive mobility. This study has implications for nursing, hospital administration, and therapy services with regard to staffing and cost savings related to fewer complications of immobility. Future studies with a larger sample size and other populations are warranted.
Combined refrigeration system with a liquid pre-cooling heat exchanger
Gaul, Christopher J.
2003-07-01
A compressor-pump unit for use in a vapor-compression refrigeration system is provided. The compressor-pump unit comprises a driving device including a rotatable shaft. A compressor is coupled with a first portion of the shaft for compressing gaseous refrigerant within the vapor-compression refrigeration system. A liquid pump is coupled with a second portion of the shaft for receiving liquid refrigerant having a first pressure and for discharging the received liquid refrigerant at a second pressure with the second pressure being higher than the first pressure by a predetermined amount such that the discharged liquid refrigerant is subcooled. A pre-cooling circuit is connected to the liquid pump with the pre-cooling circuit being exposed to the gaseous refrigerant whereby the gaseous refrigerant absorbs heat from the liquid refrigerant, prior to the liquid refrigerant entering the liquid pump.
NASA Astrophysics Data System (ADS)
Latimer, T. W.; Rinehart, G. H.
1992-05-01
This report covers progress on the Milliwatt Generator Project from April 1986 through March 1988. Activities included fuel processing and characterization, production of heat sources, fabrication of pressure-burst test units, compatibility studies, impact testing, and examination of surveillance units. The major task of the Los Alamos Milliwatt Generator Project is to fabricate MC2893A heat sources (4.0 W) for MC2730A radioisotope thermoelectric generators (RTG's) and MC3599 heat sources (4.5 W) for MC3500 RTG's. The MWG Project interfaces with the following contractors: Sandia National Laboratories, Albuquerque (designer); E.I. du Pont de Nemours and Co. (Inc.), Savannah River Plant (fuel); Monsanto Research Corporation, Mound Facility (metal hardware); and General Electric Company, Neutron Devices Department (RTG's). In addition to MWG fabrication activities, Los Alamos is involved in (1) fabrication of pressure-burst test units, (2) compatibility testing and evaluation, (3) examination of surveillance units, and (4) impact testing and subsequent examination of compatibility and surveillance units.
Military Potential Test of Elapsed-Time Indicator, P/N 85986X
1967-06-13
consisting basically of an electrolytic mercury cell, an accutron-quality mercury battery, and a pressure switch . The unit weighs 1. 687 ounces. Installed, it...orientation from 18 inches’ distance. The test item is actuated by a pressure switch which senses an actuating pressure of 40 t 5 pounds per square inch
46 CFR 58.30-5 - Design requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... § 58.30-1 of this part, except as modified herein. The designer should consider the additional pressure due to hydraulic shock and should also consider the rate of pressure rise caused by hydraulic shock... back pressure in the system. The design shall be such that malfunctioning of any unit in the system...
46 CFR 58.30-5 - Design requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... § 58.30-1 of this part, except as modified herein. The designer should consider the additional pressure due to hydraulic shock and should also consider the rate of pressure rise caused by hydraulic shock... back pressure in the system. The design shall be such that malfunctioning of any unit in the system...
46 CFR 58.30-5 - Design requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... § 58.30-1 of this part, except as modified herein. The designer should consider the additional pressure due to hydraulic shock and should also consider the rate of pressure rise caused by hydraulic shock... back pressure in the system. The design shall be such that malfunctioning of any unit in the system...
Neonatal Pressure Ulcer Prevention.
Scheans, Patricia
2015-01-01
The incidence of pressure ulcers in acutely ill infants and children ranges up to 27 percent in intensive care units, with a range of 16-19 percent in NICUs. Anatomic, physiologic, and developmental factors place ill and preterm newborns at risk for skin breakdown. Two case studies illustrate these factors, and best practices for pressure ulcer prevention are described.
77 FR 57001 - Airworthiness Directives; Pratt & Whitney Canada, Auxiliary Power Units
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-17
... exhaust duct flanges. This AD was prompted by several events of high-pressure turbine blade fracture... have experienced several events of High Pressure Turbine (HPT) blade fracture, some of which have..., 2011, and our AD will not prevent high pressure turbine blades from failing. We do not agree. The root...
Apparatus and methods for supplying auxiliary steam in a combined cycle system
Gorman, William G.; Carberg, William George; Jones, Charles Michael
2002-01-01
To provide auxiliary steam, a low pressure valve is opened in a combined cycle system to divert low pressure steam from the heat recovery steam generator to a header for supplying steam to a second combined cycle's steam turbine seals, sparging devices and cooling steam for the steam turbine if the steam turbine and gas turbine lie on a common shaft with the generator. Cooling steam is supplied the gas turbine in the combined cycle system from the high pressure steam turbine. Spent gas turbine cooling steam may augment the low pressure steam supplied to the header by opening a high pressure valve whereby high and low pressure steam flows are combined. An attemperator is used to reduce the temperature of the combined steam in response to auxiliary steam flows above a predetermined flow and a steam header temperature above a predetermined temperature. The auxiliary steam may be used to start additional combined cycle units or to provide a host unit with steam turbine cooling and sealing steam during full-speed no-load operation after a load rejection.
Tables for pressure of air on coming to rest from various speeds
NASA Technical Reports Server (NTRS)
Zahm, A F; Louden, F A
1930-01-01
In Technical Report no. 247 of the National Advisory Committee for Aeronautics theoretical formulas are given from which was computed a table for the pressure of air on coming to rest from various speeds, such as those of aircraft and propeller blades. In that report, the table gave incompressible and adiabatic stop pressures of air for even-speed intervals in miles per hour and for some even-speed intervals in knots per hour. Table II of the present report extends the above-mentioned table by including the stop pressures of air for even-speed intervals in miles per hour, feet per-second, knots per hour, kilometers per hour, and meters per second. The pressure values in table II are also more exact than values given in the previous table. To furnish the aeronautical engineer with ready numerical formulas for finding the pressure of air on coming to rest, table I has been derived for the standard values specified below it. This table first presents the theoretical pressure-speed formulas and their working forms in C. G. S. Units as given in NACA Technical Report No. 247, then furnishes additional working formulas for several special units of speed. (author)
49 CFR 192.143 - General requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... anticipated loadings without impairment of its serviceability with unit stresses equivalent to those allowed... upon unit stresses is impractical for a particular component, design may be based upon a pressure...
49 CFR 192.143 - General requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... anticipated loadings without impairment of its serviceability with unit stresses equivalent to those allowed... upon unit stresses is impractical for a particular component, design may be based upon a pressure...
49 CFR 192.143 - General requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... anticipated loadings without impairment of its serviceability with unit stresses equivalent to those allowed... upon unit stresses is impractical for a particular component, design may be based upon a pressure...
Usher, Kim; Woods, Cindy; Brown, Janie; Power, Tamara; Lea, Jackie; Hutchinson, Marie; Mather, Carey; Miller, Andrea; Saunders, Annette; Mills, Jane; Zhao, Lin; Yates, Karen; Bodak, Marie; Southern, Joanne; Jackson, Debra
2018-05-01
The aim of this study was to assess student nurses' knowledge of and attitudes towards pressure injury prevention evidence-based guidelines. Pressure injuries are a substantial problem in many healthcare settings causing major harm to patients, and generating major economic costs for health service providers. Nurses have a crucial role in the prevention of pressure injuries across all health care settings. A multi-centered, cross-sectional study was conducted using a paper-based questionnaire with undergraduate nursing students enrolled in seven universities with campuses across five Australian states (Queensland, New South Wales, Western Australia, Victoria and Tasmania). Data were collected from nursing students using two validated instruments (Pressure Ulcer Knowledge Assessment Instrument and Attitude Toward Pressure Ulcer Prevention Instrument), to measure students' pressure injury prevention knowledge and attitudes. Students reported relatively low pressure injury prevention knowledge scores (51%), and high attitude scores (78%). Critical issues in this study were nursing students' lack of knowledge about preventative strategies to reduce the amount and duration of pressure/shear, and lower confidence in their capability to prevent pressure injury. Level of education and exposure to working in a greater number of different clinical units were significantly related to pressure injury prevention knowledge and attitude scores. The study findings highlight the need to implement a comprehensive approach to increasing Australian nursing students' pressure injury prevention and management knowledge, as well as ensuring that these students have adequate experiences in clinical units, with a high focus on pressure injury prevention to raise their personal capability. Copyright © 2018 Elsevier Ltd. All rights reserved.
He, Chiyang; Zhu, Zaifang; Gu, Congying; Lu, Joann; Liu, Shaorong
2012-03-02
Numerous micropumps have been developed, but few of them can produce adequate flow rate and pressure for high-performance liquid chromatography (HPLC) applications. We have recently developed an innovative hybrid electroosmotic pump (EOP) to solve this problem. The basic unit of a hybrid pump consists of a +EOP (the pumping element is positively charged) and a -EOP (the pumping element is negatively charged). The outlet of the +EOP is then joined with the inlet of the -EOP, forming a basic pump unit, while the anode of a positive high voltage (HV) power supply is placed at the joint. The inlet and outlet of this pump unit are electrically grounded. With this configuration, we can stack many of such pump units in series to boost the pumping power. In this work, we describe in details how an open-capillary hybrid EOP is constructed and characterize this pump systematically. We also show that a hybrid EOP with ten serially stacked pump units can deliver a maximum pressure of 21.5 MPa (∼3100 psi). We further demonstrate the feasibility of using this hybrid EOP to drive eluents for HPLC separations of proteins and peptides. Copyright © 2012 Elsevier B.V. All rights reserved.
He, Chiyang; Zhu, Zaifang; Gu, Congying; ...
2012-01-09
Numerous micropumps have been developed, but few of them can produce adequate flow rate and pressure for high-performance liquid chromatography (HPLC) applications. We have recently developed an innovative hybrid electroosmotic pump (EOP) to solve this problem. The basic unit of a hybrid pump consists of a +EOP (the pumping element is positively charged) and a -EOP (the pumping element is negatively charged). The outlet of the +EOP is then joined with the inlet of the -EOP, forming a basic pump unit, while the anode of a positive high voltage (HV) power supply is placed at the joint. The inlet andmore » outlet of this pump unit are electrically grounded. With this configuration, we can stack many of such pump units in series to boost the pumping power. In this work, we describe in details how an open-capillary hybrid EOP is constructed and characterize this pump systematically. We also show that a hybrid EOP with ten serially stacked pump units can deliver a maximum pressure of 21.5 MPa (~3100 psi). Here, we further demonstrate the feasibility of using this hybrid EOP to drive eluents for HPLC separations of proteins and peptides.« less
Method and apparatus for reconstructing in-cylinder pressure and correcting for signal decay
Huang, Jian
2013-03-12
A method comprises steps for reconstructing in-cylinder pressure data from a vibration signal collected from a vibration sensor mounted on an engine component where it can generate a signal with a high signal-to-noise ratio, and correcting the vibration signal for errors introduced by vibration signal charge decay and sensor sensitivity. The correction factors are determined as a function of estimated motoring pressure and the measured vibration signal itself with each of these being associated with the same engine cycle. Accordingly, the method corrects for charge decay and changes in sensor sensitivity responsive to different engine conditions to allow greater accuracy in the reconstructed in-cylinder pressure data. An apparatus is also disclosed for practicing the disclosed method, comprising a vibration sensor, a data acquisition unit for receiving the vibration signal, a computer processing unit for processing the acquired signal and a controller for controlling the engine operation based on the reconstructed in-cylinder pressure.
Reduced Lung Cancer Mortality With Lower Atmospheric Pressure.
Merrill, Ray M; Frutos, Aaron
2018-01-01
Research has shown that higher altitude is associated with lower risk of lung cancer and improved survival among patients. The current study assessed the influence of county-level atmospheric pressure (a measure reflecting both altitude and temperature) on age-adjusted lung cancer mortality rates in the contiguous United States, with 2 forms of spatial regression. Ordinary least squares regression and geographically weighted regression models were used to evaluate the impact of climate and other selected variables on lung cancer mortality, based on 2974 counties. Atmospheric pressure was significantly positively associated with lung cancer mortality, after controlling for sunlight, precipitation, PM2.5 (µg/m 3 ), current smoker, and other selected variables. Positive county-level β coefficient estimates ( P < .05) for atmospheric pressure were observed throughout the United States, higher in the eastern half of the country. The spatial regression models showed that atmospheric pressure is positively associated with age-adjusted lung cancer mortality rates, after controlling for other selected variables.
Padula, Cynthia A; Paradis, Heidi; Goodwin, Robert; Lynch, Judith; Hegerich-Bartula, Deborah
Medical devices have been identified as an extrinsic risk factor for development of pressure injuries, with as many as 30% to 70% of medical device-related pressure injuries resulting from respiratory equipment. This article describes a quality improvement project undertaken to reduce the occurrence of respiratory device-related pressure injuries in a critically care unit. Multiple actions were implemented to achieve this goal. Respiratory therapists were trained to document occurrences on a daily basis, and apparent cause analyses were conducted on each occurrence. An interdisciplinary team conducted biweekly rounds on patients with respiratory devices and consulted other professionals as indicated. Nurses and respiratory therapists attended an evidence-based, collaborative, educational offering and completed a measure of team functioning before the program and at the end of the study period. The occurrence rates of respiratory device-related pressure injuries were reduced over the project period, and these changes were sustained over the subsequent 12 months.
NASA Technical Reports Server (NTRS)
Kovich, G.; Moore, R. D.; Urasek, D. C.
1973-01-01
The overall and blade-element performance are presented for an air compressor stage designed to study the effect of weight flow per unit annulus area on efficiency and flow range. At the design speed of 424.8 m/sec the peak efficiency of 0.81 occurred at the design weight flow and a total pressure ratio of 1.56. Design pressure ratio and weight flow were 1.57 and 29.5 kg/sec (65.0 lb/sec), respectively. Stall margin at design speed was 19 percent based on the weight flow and pressure ratio at peak efficiency and at stall.
High pressure system for 3-D study of elastic anisotropy
NASA Astrophysics Data System (ADS)
Lokajicek, T.; Pros, Z.; Klima, K.
2003-04-01
New high pressure system was designed for the study of elastic anisotropy of condensed matter under high confining pressure up to 700 MPa. Simultaneously could be measured dynamic and static parameters: a) dynamic parameters by ultrasonic sounding, b) static parameters by measuring of spherical sample deformation. The measurement is carried out on spherical samples diameter 50 +/- 0.01 mm. Higher value of confining pressure was reached due to the new construction of sample positioning unit. The positioning unit is equipped with two Portecap step motors, which are located inside the vessel and make possible to rotate with the sphere and couple of piezoceramic transducers. Sample deformation is measured in the same direction as ultrasonic signal travel time. Only electric leads connects inner part of high pressure vessel with surrounding environment. Experimental set up enables: - simultaneous P-wave ultrasonic sounding, - measurement of current sample deformation at sounding points, - measurement of current value of confining pressure and - measurement of current stress media temperature. Air driven high pressure pump Haskel is used to produce high value of confining pressure up to 700 MPa. Ultrasonic signals are recorded by digital scope Agilent 54562 with sampling frequency 100 MHz. Control and measuring software was developed under Agilent VEE software environment working under MS Win 2000 operating system. Measuring set up was tested by measurement of monomineral spherical samples of quartz and corundum. Both of them have trigonal symmetry. The measurement showed that the P-wave velocity range of quartz was between 5.7-7.0 km/sec. and velocity range of corundum was between 9.7-10.9 km/sec. High pressure resistant LVDT transducers Mesing together with Intronix electronic unit were used to monitor sample deformation. Sample deformation is monitored with the accuracy of 0.1 micron. All test measurements proved the good accuracy of the whole measuring set up. This project was supported by Grant Agency of the Czech Republic No.: 205/01/1430.
Finite Element Analysis of Functionally Graded Material to Reduce Crazing in Transparent Armor
2015-09-01
Constraints 3 Results 4 Tensile Pressure (psi) 4 Conclusions and Path Forward 5 References 7 Distribution List 9 FIGURES 1 Pressure plot 1 2 3D...Digimat unit cell and 2D plane strain model for ABAQUS 2 3 Control and FGM models 3 4 Boundary conditions 4 5 Pressure results (time = 23.47 µs) 4...6 Pressure results 1 5 7 Pressure results 2 5 UNCLASSIFIED Approved for public release; distribution is unlimited. 1 INTRODUCTION
Factors contributing to evidence-based pressure ulcer prevention. A cross-sectional study.
Sving, Eva; Idvall, Ewa; Högberg, Hans; Gunningberg, Lena
2014-05-01
Implementation of evidence-based care for pressure ulcer prevention is lacking. As the hospital organization is complex, more knowledge is needed to understand how nursing care in this area can be improved. The present study investigated the associations between variables on different levels in the healthcare setting (patient, unit, hospital) and the documentation of (1) risk assessment and (2) skin assessment within 24h of admission, the use of (3) pressure-reducing mattresses and (4) planned repositioning in bed. A cross-sectional study. One university hospital and one general hospital. Geriatric (n=8), medical (n=24) and surgical (n=19) units. All adult patients (>17 years), in total 825, were included. A one-day prevalence study was conducted using the methodology specified by the European Pressure Ulcer Advisory Panel, together with the established methods used by the Collaborative Alliance for Nursing Outcomes. Independent variables were patient characteristics, hospital type, unit type, nurse staffing and workload. Dependent variables were documented risk and skin assessment within 24h of admission, pressure-reducing mattresses and planned repositioning in bed. The data were analysed with Logistic regression using the Generalized Estimating Equation (GEE) approach. Patients at risk of developing pressure ulcers (Braden<17) had higher odds of having risk assessment documented, and of receiving pressure-reducing mattresses and planned repositioning. Patients at the general hospital were less likely to have risk and skin assessment documented and to receive pressure-reducing mattresses. On the other hand, planned repositioning was more likely to be used at the general hospital. When total hours of nursing care was lower, patients had higher odds of having pressure-reducing mattresses but were less likely to have planned repositioning. Patient characteristics (high age and risk score) and hospital type were associated with pressure ulcer prevention. Surprisingly, nurse staffing played only a minor role. Leaders in healthcare organizations should establish routines on different levels that support evidence-based pressure ulcer prevention, and registered nurses need to assume responsibility for bedside care. Copyright © 2013 Elsevier Ltd. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-05
...; Zion Nuclear Power Station, Units 1 and 2 Exemption From Recordkeeping Requirements 1.0 Background Zion Nuclear Power Station (ZNPS or Zion), Unit 1, is a Westinghouse 3250 MWt Pressurized Water Reactor which... previously applicable to the nuclear power units and associated systems, structures, and components (SSC) are...
Strand, Tillan; Lindgren, Margareta
2010-12-01
Pressure ulcer incidence varies between 1 and 56% in intensive care and prevention is an important quest for nursing staff. Critically ill patients that develop pressure ulcers suffer from increased morbidity and mortality and also requires prolonged intensive care. The aim of this study was to investigate registered nurses' and enrolled nurses' (1) attitudes, (2) knowledge and (3) perceived barriers and opportunities towards pressure ulcer prevention, in an ICU setting. These are important aspects in the Theory of Planned Behaviour, a conceptual framework when trying to predict, understand and change specific behaviours. The study is descriptive. Questionnaires were distributed to registered nurses and enrolled nurses in four ICUs in a Swedish hospital. The mean score regarding attitude was 34 ± 4. Correct categorisation of pressure ulcers was made by 46.8% of nursing staff with enrolled nurses having significantly less correct categorisation (p=0.019). Pressure relief (97.3%) and nutritional support (36.1%) were the most frequently reported preventive measures. Reported barriers were lack of time (57.8%) and severely ill patients (28.9%); opportunities were knowledge (38%) and access to pressure relieving equipment (35.5%). This study highlights areas where measures can be made to facilitate pressure ulcer prevention in intensive care units, such as raising knowledge and making pressure ulcer prevention a part of daily care. Copyright © 2010 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Yao, Z.; Bi, H. L.; Huang, Q. S.; Li, Z. J.; Wang, Z. W.
2013-12-01
In load rejection transient process, the sudden shut down of guide vanes may cause units speed rise and a sharp increase in water hammer pressure of diversion system, which endangers the safety operation of the power plant. Adopting reasonable guide vane closure law is a kind of economic and effective measurement to reduce the water hammer pressure and limit rotational speed increases. In this paper, combined with Guangzhou Pumped Storage Power Station plant A, the load rejection condition under different guide vanes closure laws is calculated and the key factor of guide vanes closure laws on the impact of the load rejection transition process is analyzed. The different inflection points, which are the closure modes, on the impact of unit speed change, water level fluctuation of surge tank, and the pressure fluctuation of volute inlet and draft tube inlet are further discussed. By compared with the calculation results, a reasonable guide vanes inflection point position can be determined according to security requirements and a reasonable guide vanes closure law can be attained to effectively coordinate the unit speed rise and the rapid pressure change in the load rejection transient process.
Protective mechanical ventilation in United Kingdom critical care units: A multicentre audit
Martin, Matthew J; Richardson, Neil; Bourdeaux, Christopher P
2016-01-01
Lung protective ventilation is becoming increasingly used for all critically ill patients being mechanically ventilated on a mandatory ventilator mode. Compliance with the universal application of this ventilation strategy in intensive care units in the United Kingdom is unknown. This 24-h audit of ventilation practice took place in 16 intensive care units in two regions of the United Kingdom. The mean tidal volume for all patients being ventilated on a mandatory ventilator mode was 7.2(±1.4) ml kg−1 predicted body weight and overall compliance with low tidal volume ventilation (≤6.5 ml kg−1 predicted body weight) was 34%. The mean tidal volume for patients ventilated with volume-controlled ventilation was 7.0(±1.2) ml kg−1 predicted body weight and 7.9(±1.8) ml kg−1 predicted body weight for pressure-controlled ventilation (P < 0.0001). Overall compliance with recommended levels of positive end-expiratory pressure was 72%. Significant variation in practice existed both at a regional and individual unit level. PMID:28979556
Protective mechanical ventilation in United Kingdom critical care units: A multicentre audit.
Newell, Christopher P; Martin, Matthew J; Richardson, Neil; Bourdeaux, Christopher P
2017-05-01
Lung protective ventilation is becoming increasingly used for all critically ill patients being mechanically ventilated on a mandatory ventilator mode. Compliance with the universal application of this ventilation strategy in intensive care units in the United Kingdom is unknown. This 24-h audit of ventilation practice took place in 16 intensive care units in two regions of the United Kingdom. The mean tidal volume for all patients being ventilated on a mandatory ventilator mode was 7.2(±1.4) ml kg -1 predicted body weight and overall compliance with low tidal volume ventilation (≤6.5 ml kg -1 predicted body weight) was 34%. The mean tidal volume for patients ventilated with volume-controlled ventilation was 7.0(±1.2) ml kg -1 predicted body weight and 7.9(±1.8) ml kg -1 predicted body weight for pressure-controlled ventilation ( P < 0.0001). Overall compliance with recommended levels of positive end-expiratory pressure was 72%. Significant variation in practice existed both at a regional and individual unit level.
Continuous Removal of Coal-Gasification Residue
NASA Technical Reports Server (NTRS)
Collins, Earl R., Jr.; Suitor, J.; Dubis, D.
1986-01-01
Continuous-flow hopper processes solid residue from coal gasification, converting it from ashes, cinders, and clinkers to particles size of sand granules. Unit does not require repeated depressurization of lockhopper to admit and release materials. Therefore consumes less energy. Because unit has no airlock valves opened and closed repeatedly on hot, abrasive particles, subjected to lesser wear. Coal-gasification residue flows slowly through pressure-letdown device. Material enters and leaves continuously. Cleanout door on each pressure-letdown chamber allows access for maintenance and emergencies.
Evaluation of BAUER High Pressure Breathing Air P-2 Purification System
1991-08-01
and is a coalescing type separator that removes oil and water vapors suspended in the compressed air . The molecular sieve is made to adsorb oil and...filtering, moisture separation, and prevents compressed air return from the charged air storage flasks to the compressor during unit shutdown. A manual...1111111111111 1111 IE IH fil91i C NAVY EXPERIMENTAL DIVING UNIT REPORT NO. 10-91 EVALUATION OF BAUER HIGH PRESSURE BREATHING AIR P-2 PURIFICATION SYSTEM GEORGE D
Molecular Association and Monolayer Formation of Soluble Phthalocyanine Compounds.
1983-04-20
stable Langmuir - Blodgett monolayer to film pressures of 20 mN/m ant force-area curves indicate a dense packing of phthalocyanine units with molecular areas...8217which is monomeric and Cu, Ni, Pd and PtpdX4 wMyi,chjform larger complexes ranging from 2.7 to 4.1 molecular units. EachU.MCx*4 forms a stable Langmuir ... Blodgett monolayer to film pressures of 20 mN/in and force-area curves indicate a dense packing of phthalocyanine urits with molecul-ar areas
Ocean Bottom Seismometer Augmentation of the Philippine Sea Experiment (OBSAPS) Cruise Report
2011-09-01
single 77.5Hz M-sequence on six OBSAPS receivers: (from bottom to top) the vertical geophone on the North OBS ( blue ), the hydrophone module on the...wet end electronics (pressure sensor, hydrophone and octopus ) to the spare J15-3 S/N 14 and re-deployed the transducer and tow body assembly. We then...our wet end electronics (hydrophone, pressure sensor and octopus ) to the S/N 11 unit and re-deployed. The repaired J15-3 S/N 11 unit performed
Coladonato, Joseph; Smith, Annette; Watson, Nancy; Brown, Anne T; McNichol, Laurie L; Clegg, Amy; Griffin, Tracy; McPhail, Lora; Montgomery, Terry G
2012-10-01
Hospital bedding and gowns influence skin moisture, temperature, friction, and shear, which in turn may affect the development of pressure ulcers. To evaluate the effect of a new silk-like synthetic fabric on the incidence of pressure ulcers in an acute care setting, two consecutive 6-month clinical trials were conducted among 307 consecutively admitted patients in a Medical Renal Unit (August 2008 and March 2010) and in 275 patients admitted to a Surgical Intensive Care Unit (ICU) (September 2009 to March 2010). During the first 8 weeks, all patients used standard hospital bed linens, reusable underpads, and gowns. During the second 8 weeks, all admitted patients used the intervention linens (a silk-like fabric) followed by another 8 weeks of control (standard linen) use. Demographic variables and the prevalence of pressure ulcers on admission were statistically similar for control and intervention groups in both study populations with the exception of gender in the Renal Unit study (13% higher proportion of men in intervention group). Average Braden Scores were also similar and low (<18) in all study patients. Upon admission to the Medical Renal Unit, 21 of 154 patients (13.6%) in the control and 26 of 153 patients (17.0%) in the intervention group had a pressure ulcer. The incidence of new ulcers was 12.3% in the control and 4.6% in the intervention group (P = 0.01); average length of stay was 5.97 days (σ = 4.0) for control and 5.31 days (σ = 3.8) for intervention patients (P = 0.07). In the Surgical ICU group, 18 of 199 patients in the control (9.1%) and four of 76 patients in the intervention group (5.3%) were admitted with a pressure ulcer; the incidence of new pressure ulcers was 7.5 % in the control and 0% in the intervention group (P = 0.01). Average length of stay was 4.5 days and 4.33 days in the control and intervention groups, respectively (P = 0.33). The significant differences between the control and intervention group in the rate of pressure ulcer development suggests that the type of linens used affect pressure ulcer risk and that this silk-like synthetic fabric technology may help reduce the incidence of pressure ulcers in high-risk patients. Controlled clinical studies in other patient populations are warranted.
Comparative Study of Barotrauma Risk during Fish Passage through Kaplan Turbines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richmond, Marshall C.; Romero-Gomez, Pedro; Serkowski, John A.
Rapid pressure changes in hydroelectric turbine flows can cause barotrauma that can be hazardous to the passage of fish, in particular migratory juvenile salmonids. Although numerous laboratory tests have evaluated the effect of rapid decompression in fish species of relevance, numerical modeling studies offer the advantage of predicting, for new turbine designs, the potential risks of mortality and injury from rapid pressure change during turbine passage. However, rapid pressure change is only one of several hydraulic risks encountered by fish during turbine passage in addition to blade strike, shear, and turbulence. To better understand the role of rapid pressure changes,more » the present work focuses on the application of a computational fluid dynamics based method for evaluating the risk of pressure-related mortality to fish passing through an early 1960s era original hydroelectric Kaplan turbine at Wanapum Dam (Columbia River, Washington), and a modern advanced Kaplan turbine installed in 2005. The results show that the modeling approach acceptably reproduced the nadir pressure distributions compared to field data previously collected at the site using an autonomous sensor. Our findings show that the new advanced-design unit performs better, in terms of reduced barotrauma risk to fish from exposure to low pressures, than the original turbine unit. The outcomes allow for comparative analyses of turbine designs and operations prior to installation, an advantage that can potentially be integrated in the process of designing new turbine units to achieve superior environmental performance. Overall, the results show that modern turbine designs can achieve the multiple objectives of increasing power generation, lowering cavitation potential, and reducing barotrauma risks to passing fish.« less
Laksmivenkateshiah, Srinivas; Singhi, Anil K; Vaidyanathan, Balu; Francis, Edwin; Karimassery, Sundaram R; Kumar, Raman K
2011-06-01
To examine the utility of decline in arterial partial pressure of oxygen after exercise as a marker of pulmonary vascular obstructive disease in patients with atrial septal defect and pulmonary hypertension. Treadmill exercise was performed in 18 patients with atrial septal defect and pulmonary hypertension. Arterial blood gas samples were obtained before and after peak exercise. A decline in the arterial pressure of oxygen of more than 10 millimetres of mercury after exercise was considered significant based on preliminary tests conducted on the controls. Cardiac catheterisation was performed in all patients and haemodynamic data sets were obtained on room air, oxygen, and a mixture of oxygen and nitric oxide (30-40 parts per million). There were 10 patients who had more than a 10 millimetres of mercury drop in arterial partial pressure of oxygen after exercise and who had a basal pulmonary vascular resistance index of more than 7 Wood units per square metre. Out of eight patients who had less than a 10 millimetres of mercury drop in arterial partial pressure of oxygen after exercise, seven had a basal pulmonary vascular resistance index of less than 7 Wood units per square metre, p equals 0.0001. A decline in arterial partial pressure of oxygen of more than 10 millimetres of mercury predicted a basal pulmonary vascular resistance index of more than 7 Wood units per square metre with a specificity of 100% and a sensitivity of 90%. A decline in arterial partial pressure of oxygen following exercise appears to predict a high pulmonary vascular resistance index in patients with atrial septal defect and pulmonary hypertension. This test is a useful non-invasive marker of pulmonary vascular obstructive disease in this subset.
Gamble, J; Gartside, I B; Christ, F
1993-01-01
1. We have used non-invasive mercury in a silastic strain gauge system to assess the effect of pressure step size, on the time course of the rapid volume response (RVR) to occlusion pressure. We also obtained values for hydraulic conductance (Kf), isovolumetric venous pressure (Pvi) and venous pressure (Pv) in thirty-five studies on the legs of twenty-three supine control subjects. 2. The initial rapid volume response to small (9.53 +/- 0.45 mmHg, mean +/- S.E.M.) stepped increases in venous pressure, the rapid volume response, could be described by a single exponential of time constant 15.54 +/- 1.14 s. 3. Increasing the size of the pressure step, to 49.8 +/- 1.1 mmHg, gave a larger value for the RVR time constant (mean 77.3 +/- 11.6 s). 4. We propose that the pressure-dependent difference in the duration of the rapid volume response, in these two situations, might be due to a vascular smooth muscle-based mechanism, e.g. the veni-arteriolar reflex. 5. The mean (+/- S.E.M.) values for Kf, Pvi and Pv were 4.27 +/- 0.18 (units, ml min-1 (100 g)-1 mmHg-1 x 10(-3), 21.50 +/- 0.81 (units, mmHg) and 9.11 +/- 0.94 (units, mmHg), respectively. 6. During simultaneous assessment of these parameters in arms and legs, it was found that they did not differ significantly from one another. 7. We propose that the mercury strain gauge system offers a useful, non-invasive means of studying the mechanisms governing fluid filtration in human limbs. Images Fig. 1 PMID:8229810
Modrykamien, Ariel M; Hernandez, Omar O; Im, Yunhee; Walters, Ryan W; Schrader, Caleb L; Smith, Lauren E; Lima, Brian
2016-01-01
Mechanical ventilation support for acute respiratory distress syndrome (ARDS) patients involves the use of low tidal volumes and positive end-expiratory pressure. Nevertheless, the optimal ventilator strategy for ARDS patients undergoing extracorporeal membrane oxygenation (ECMO) therapy remains unknown. A retrospective analysis of a consecutive series of adult ARDS patients treated with V-V ECMO from October 2012 to May 2015 was performed. Mechanical ventilation data, as well as demographic and clinical data, were collected. We assessed the association between ventilator data and outcomes of interest. The primary outcome was hospital survival. Secondary outcome was 30 day survival posthospital discharge. Sixty-four ARDS patients were treated with ECMO. Univariate analysis showed that plateau pressure was independently associated with hospital survival. Tidal volume, positive end-expiratory pressure (PEEP), and plateau were independently associated with 30 day survival. Multivariate analysis, after controlling for covariates, revealed that a 1 unit increase in plateau pressure was associated with a 21% decrease in the odds of hospital survival (95% confidence interval [CI] = 6.39-33.42%, p = 0.007). In regards to 30 day survival postdischarge, a 1 unit increase in plateau pressure was associated with a 14.4% decrease in the odds of achieving the aforementioned outcome (95% CI = 1.75-25.4%, p = 0.027). Also, a 1 unit increase in PEEP was associated with a 36.2% decrease in the odds of 30 day survival (95% CI = 10.8-54.4%, p = 0.009). Among ARDS patients undergoing ECMO therapy, only plateau pressure is associated with hospital survival. Plateau pressure and PEEP are both associated with 30 day survival posthospital discharge.
Harding, Seeromanie; Whitrow, Melissa; Lenguerrand, Erik; Maynard, Maria; Teyhan, Alison; Cruickshank, J Kennedy; Der, Geoff
2010-04-01
The cause of ethnic differences in cardiovascular disease remains a scientific challenge. Blood pressure tracks from late childhood to adulthood. We examined ethnic differences in changes in blood pressure between early and late adolescence in the United Kingdom. Longitudinal measures of blood pressure, height, weight, leg length, smoking, and socioeconomic circumstances were obtained from London, United Kingdom, schoolchildren of White British (n=692), Black Caribbean (n=670), Black African (n=772), Indian (n=384), and Pakistani and Bangladeshi (n=402) ethnicity at 11 to 13 years and 14 to 16 years. Predicted age- and ethnic-specific means of blood pressure, adjusted for anthropometry and social exposures, were derived using mixed models. Among boys, systolic blood pressure did not differ by ethnicity at 12 years, but the greater increase among Black Africans than Whites led to higher systolic blood pressure at 16 years (+2.9 mm Hg). Among girls, ethnic differences in mean systolic blood pressure were not significant at any age, but while systolic blood pressure hardly changed with age among White girls, it increased among Black Caribbeans and Black Africans. Ethnic differences in diastolic blood pressure were more marked than those for systolic blood pressure. Body mass index, height, and leg length were independent predictors of blood pressure, with few ethnic-specific effects. Socioeconomic disadvantage had a disproportionate effect on blood pressure for girls in minority groups. The findings suggest that ethnic divergences in blood pressure begin in adolescence and are particularly striking for boys. They signal the need for early prevention of adverse cardiovascular disease risks in later life.
Dukes, Susan F; Maupin, Genny M; Thomas, Marilyn E; Mortimer, Darcy L
2018-04-01
The US Air Force transports critically ill patients from all over the world, with transport times commonly ranging from 6 to 11 hours. Few outcome measures have been tracked for these patients. Traditional methods to prevent pressure injuries in civilian hospitals are often not feasible in the military transport environment. The incidence rate and risk factors are described of en route-related pressure injuries for patients overseen by the Critical Care Air Transport Team. This retrospective, case-control, medical records review investigated risk factors for pressure injury in patients who developed a pressure injury after their transport flight compared with those with no documented pressure injuries. The pressure injury rate was 4.9%. Between 2008 and 2012, 141 patients in whom pressure injuries developed and who had received care by the team were matched with 141 patients cared for by the team but did not have pressure injury. According to regression analysis, body mass index and 2 or more Critical Care Air Transport Team transports per patient were associated with pressure injury development. Although the pressure injury rate of 4.9% in this cohort of patients is consistent with that reported by civilian critical care units, the rate must be interpreted with caution, because civilian study data frequently represent the entire intensive care unit length of stay. Targeted interventions for patients with increased body mass index and 2 or more critical care air transports per patient may help decrease the development of pressure injury in these patients. ©2018 American Association of Critical-Care Nurses.
49 CFR 232.403 - Design standards for one-way end-of-train devices.
Code of Federal Regulations, 2010 CFR
2010-10-01
... valve to prevent explosion from a high pressure air leak inside the rear unit. (c) Reporting rate... shall be capable of determining the brake pipe pressure on the rear car and transmitting that... measuring the brake pipe pressure on the rear car with an accuracy of ±3 pounds per square inch (psig) and...
46 CFR 109.421 - Report of repairs to boilers and pressure vessels.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Report of repairs to boilers and pressure vessels. 109.421 Section 109.421 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Reports, Notifications, and Records Reports and Notifications § 109.421 Report of repairs to boilers and pressure vessel...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-30
... seal and allowed the pressure in certain slides/ rafts to fall below the minimum raft mode pressure for the unit. We are issuing this AD to prevent loss of pressure in the escape slides/rafts after an emergency evacuation, which could result in inadequate buoyancy to support the raft's passenger capacity...
Particle-In-Cell simulations of high pressure plasmas using graphics processing units
NASA Astrophysics Data System (ADS)
Gebhardt, Markus; Atteln, Frank; Brinkmann, Ralf Peter; Mussenbrock, Thomas; Mertmann, Philipp; Awakowicz, Peter
2009-10-01
Particle-In-Cell (PIC) simulations are widely used to understand the fundamental phenomena in low-temperature plasmas. Particularly plasmas at very low gas pressures are studied using PIC methods. The inherent drawback of these methods is that they are very time consuming -- certain stability conditions has to be satisfied. This holds even more for the PIC simulation of high pressure plasmas due to the very high collision rates. The simulations take up to very much time to run on standard computers and require the help of computer clusters or super computers. Recent advances in the field of graphics processing units (GPUs) provides every personal computer with a highly parallel multi processor architecture for very little money. This architecture is freely programmable and can be used to implement a wide class of problems. In this paper we present the concepts of a fully parallel PIC simulation of high pressure plasmas using the benefits of GPU programming.
Sullivan, Elizabeth A; Dickinson, Jan E; Vaughan, Geraldine A; Peek, Michael J; Ellwood, David; Homer, Caroline S E; Knight, Marian; McLintock, Claire; Wang, Alex; Pollock, Wendy; Jackson Pulver, Lisa; Li, Zhuoyang; Javid, Nasrin; Denney-Wilson, Elizabeth; Callaway, Leonie
2015-12-02
Super-obesity is associated with significantly elevated rates of obstetric complications, adverse perinatal outcomes and interventions. The purpose of this study was to determine the prevalence, risk factors, management and perinatal outcomes of super-obese women giving birth in Australia. A national population-based cohort study. Super-obese pregnant women (body mass index (BMI) >50 kg/m(2) or weight >140 kg) who gave birth between January 1 and October 31, 2010 and a comparison cohort were identified using the Australasian Maternity Outcomes Surveillance System (AMOSS). Outcomes included maternal and perinatal morbidity and mortality. Prevalence estimates calculated with 95% confidence intervals (CIs). Adjusted odds ratios (ORs) were calculated using multivariable logistic regression. 370 super-obese women with a median BMI of 52.8 kg/m(2) (range 40.9-79.9 kg/m(2)) and prevalence of 2.1 per 1 000 women giving birth (95% CI: 1.96-2.40). Super-obese women were significantly more likely to be public patients (96.2%), smoke (23.8%) and be socio-economically disadvantaged (36.2%). Compared with other women, super-obese women had a significantly higher risk for obstetric (adjusted odds ratio (AOR) 2.42, 95% CI: 1.77-3.29) and medical (AOR: 2.89, 95% CI: 2.64-4.11) complications during pregnancy, birth by caesarean section (51.6%) and admission to special care (HDU/ICU) (6.2%). The 372 babies born to 365 super-obese women with outcomes known had significantly higher rates of birthweight ≥ 4500 g (AOR 19.94, 95 % CI: 6.81-58.36), hospital transfer (AOR 3.81, 95 % CI: 1.93-7.55) and admission to Neonatal Intensive Care Unit (NICU) (AOR 1.83, 95% CI: 1.27-2.65) compared to babies of the comparison group, but not prematurity (10.5% versus 9.2%) or perinatal mortality (11.0 (95% CI: 4.3-28.0) versus 6.6 (95% CI: 2.6- 16.8) per 1 000 singleton births). Super-obesity in pregnancy in Australia is associated with increased rates of pregnancy and birth complications, and with social disadvantage. There is an urgent need to further address risk factors leading to super-obesity among pregnant women and for maternity services to better address pre-pregnancy and pregnancy care to reduce associated inequalities in perinatal outcomes.
Instrument for Analysis of Greenland's Glacier Mills
NASA Technical Reports Server (NTRS)
Behar, Alberto E.; Matthews, Jaret B.; Tran, Hung B.; Steffen, Konrad; McGrath, Dan; Phillips, Thomas; Elliot, Andrew; OHern, Sean; Lutz, Colin; Martin, Sujita;
2010-01-01
A new instrument is used to study the inner workings of Greenland s glacier mills by riding the currents inside a glacier s moulin. The West Greenland Moulin Explorer instrument was deployed into a tubular shaft to autonomously record temperature, pressure, 3D acceleration, and location. It is built with a slightly positive buoyancy in order to assist in recovery. The unit is made up of several components. A 3-axis MEMS (microelectromechanical systems) accelerometer with 0.001-g resolution forms the base of the unit. A pressure transducer is added that is capable of withstanding 500 psi (=3.4 MPa), and surviving down to -40 C. An Iridium modem sends out data every 10 minutes. The location is traced by a GPS (Global Positioning System) unit. This GPS unit is also used for recovery after the mission. Power is provided by a high-capacity lithium thionyl chloride D-sized battery. The accelerometer is housed inside a cylindrical, foot-long (=30 cm) polyvinyl chloride (PVC) shell sealed at each end with acrylic. The pressure transducer is attached to one of these lids and a MEMS accelerometer to the other, recording 100 samples per second per axis.
Gómez, Eduardo J
2011-04-01
Using a temporal approach dividing the reform process into two periods, this article explains how both Brazil and the United States were slow to respond to AIDS. However, Brazil eventually outpaced the United States in its response due to international rather than democratic pressures. Since the early 1990s, Brazil's success has been attributed to "strategic internationalization": the concomitant acceptance and rejection of global pressure for institutional change and antiretroviral treatment, respectively. The formation of tripartite partnerships among donors, AIDS officials, and nongovernmental organizations has allowed Brazil to avoid foreign aid dependency, while generating ongoing incentives for influential AIDS officials to incessantly pressure Congress for additional funding. Given the heightened international media attention, concern about Brazil's reputation has contributed to a high level of political commitment. By contrast, the United States' more isolationist relationship with the international community, its focus on leading the global financing of AIDS efforts, and the absence of tripartite partnerships have prevented political leaders from adequately responding to the ongoing urban AIDS crisis. Thus, Brazil shows that strategically working with the international health community for domestic rather than international influence is vital for a sustained and effective response to AIDS.
Initial comparison of single cylinder Stirling engine computer model predictions with test results
NASA Technical Reports Server (NTRS)
Tew, R. C., Jr.; Thieme, L. G.; Miao, D.
1979-01-01
A NASA developed digital computer code for a Stirling engine, modelling the performance of a single cylinder rhombic drive ground performance unit (GPU), is presented and its predictions are compared to test results. The GPU engine incorporates eight regenerator/cooler units and the engine working space is modelled by thirteen control volumes. The model calculates indicated power and efficiency for a given engine speed, mean pressure, heater and expansion space metal temperatures and cooler water inlet temperature and flow rate. Comparison of predicted and observed powers implies that the reference pressure drop calculations underestimate actual pressure drop, possibly due to oil contamination in the regenerator/cooler units, methane contamination in the working gas or the underestimation of mechanical loss. For a working gas of hydrogen, the predicted values of brake power are from 0 to 6% higher than experimental values, and brake efficiency is 6 to 16% higher, while for helium the predicted brake power and efficiency are 2 to 15% higher than the experimental.
Petalite under pressure: Elastic behavior and phase stability
Ross, Nancy L.; Zhao, Jing; Slebodnick, Carla; ...
2015-04-01
The lithium aluminosilicate mineral petalite (LiAlSi 4O 10) has been studied using high-pressure single-crystal X-ray diffraction (HP-XRD) up to 5 GPa. Petalite undergoes two pressure-induced first-order phase transitions, never reported in the literature, at ca. 1.5 and 2.5 GPa. The first of these transforms the low-pressure α-phase of petalite (P2/c) to an intermediate β-phase that then fully converts to the high-pressure β-phase at ca. 2.5 GPa. The α→β transition is isomorphic and is associated with a commensurate modulation that triples the unit cell volume. Analysis of the HP-XRD data show that although the fundamental features of the petalite structure aremore » retained through this transition, there are subtle alterations in the internal structure of the silicate double-layers in the β-phase relative to the α-phase. Measurement of the unit cell parameters of petalite as a function of pressure, and fitting of the data with 3rd order Birch-Murnaghan equations of state, has provided revised elastic constants for petalite. The bulk moduli of the α and β-phases are 49(1) and 35(3) GPa, respectively. These values indicate that the compressibility of the- phase of petalite lies between the alkali feldpsars and alkali feldspathoids, whereas the β-phase has a compressibility more comparable with layered silicates. Structure analysis has shown that the compression of the -phase is facilitated by the rigid body movement of the Si 2O 7 units from which the silicate double-layers are constructed.« less
Compressional behavior of omphacite to 47 GPa
Zhang, Dongzhou; Hu, Yi; Dera, Przemyslaw K.
2016-07-08
Omphacite is an important mineral component of eclogite. Single crystal synchrotron X-ray diffraction data on natural (Ca,Na)(Mg,Fe,Al)Si 2O 6 omphacite have been collected at the Advanced Photon Source beamlines 13-BM-C and 13-ID-D up to 47 GPa at ambient temperature. Unit cell parameter and crystal structure refinements were carried out to constrain the isothermal equation of state and compression mechanism. The 3rd order Birch-Murnaghan equation of state (BM3) fit of all data gives V o = 423.9(3) Å3, K To = 116(2) GPa and K To’ = 4.3(2). These elastic parameters are consistent with the general trend of the diopside-jadeite join.more » The eight-coordinated polyhedra (M2 and M21) are the most compressible, and contribute to majority of the unit cell compression, while the SiO 4 tetrahedra (Si1 and Si2) behave as rigid structural units and are the most incompressible. Axial compressibilities are determined by fitting linearized BM 3 equation of state to pressure dependences of unit cell parameters. Throughout the investigated pressure range, the b-axis is more compressible than the c-axis. Here, the axial compressibility of the α-axis is the largest among the three axes at 0 GPa, yet it quickly drops to the smallest at pressures above 5 GPa, which is explained by the rotation of the stiffest compression axis toward the a-axis with the increase of pressure.« less
NASA Astrophysics Data System (ADS)
Povarova, K. B.; Valitov, V. A.; Drozdov, A. A.; Bazyleva, O. A.; Galieva, E. V.; Arginbaeva, E. G.
2018-01-01
The possibility of formation of a high-quality solid-phase joint of an Ni3Al-based single-crystal intermetallic VKNA-25 blade alloy with a high-temperature deformable EP975 disk alloy by pressure welding is studied to create high-performance one-piece blisk unit for the next-generation aviation gas turbine engines and to decrease the unit mass. The influence of the conditions of thermodiffusion pressure welding under the hightemperature superplasticity of the disk alloy and the influence of heat treatment of welded joints on the gradient structures in the welded joint zone and the structure at the periphery of the welded samples are investigated.
Nurses' attitudes towards pressure ulcer prevention in Turkey.
Aslan, Arzu; Yavuz van Giersbergen, Meryem
2016-02-01
Pressure ulcers remain a major problem in healthcare system. Pressure ulcer incidence is widely accepted as an indicator for the quality of care. Positive attitudes towards pressure ulcer prevention have positive impacts on preventive care. The aim of this study was to identify nurses' attitude towards pressure ulcer prevention. The study design was descriptive. The study was carried out in a university hospital in Izmir, Turkey. The study population consisted of 660 nurses who work in medical and surgical clinics and intensive care units. The study sample consisted of 426 nurses who agreed to participate. Attitude towards Pressure Ulcer Prevention Instrument was used in order to evaluate nurses' attitudes. Written permissions for ethical considerations and Attitude towards Pressure Ulcer Prevention Instrument permission were obtained. Data were collected between June and July 2014. The statistics program SPSS 18 packaged software was used in the analyses of data. The average age of the nurses who took part in the study was 31.86 ± 7.09 years and the average work experience was 8.88 ± 7.41 years; 36.9% (n: 157) were working in intensive care units. The nurses' average score on the Attitude towards Pressure Ulcer Prevention Instrument was 43.74 ± 4.29 (84.12%). It was seen that the attitudes of the nurses towards the prevention of pressure ulcers was positive. To read guidelines and training time about pressure ulcer prevention affect positively attitudes towards the prevention of pressure ulcers. Copyright © 2015 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Valamin, A. E.; Kultyshev, A. Yu.; Shibaev, T. L.; Gol'dberg, A. A.; Sakhnin, Yu. A.; Stepanov, M. Yu.; Bilan, V. N.; Kadkina, I. V.
2016-11-01
The selection of a cogeneration steam turbine unit (STU) for the reconstruction of power units with a T-250/300-23.5 turbine is substantiated by the example of power unit no. 9 at the cogeneration power station no. 22 (TETs-22) of Mosenergo Company. Series T-250 steam turbines have been developed for combined heat and power generation. A total of 31 turbines were manufactured. By the end of 2015, the total operation time of prototype power units with the T-250/300-23.5 turbine exceeded 290000 hours. Considering the expiry of the service life, the decision was made that the reconstruction of the power unit at st. no. 9 of TETs-22 should be the first priority. The main issues that arose in developing this project—the customer's requirements and the request for the reconstruction, the view on certain problems of Ural Turbine Works (UTZ) as the manufacturer of the main power unit equipment, and the opinions of other project parties—are examined. The decisions were made with account taken of the experience in operation of all Series T-250 turbines and the results of long-term discussions of pressing problems at scientific and technical councils, meetings, and negotiations. For the new power unit, the following parameters have been set: a live steam pressure of 23.5 MPa and live steam/reheat temperature of 565/565°C. Considering that the boiler equipment will be upgraded, the live steam flow is increased up to 1030 t/h. The reconstruction activities involving the replacement of the existing turbine with a new one will yield a service life of 250000 hours for turbine parts exposed to a temperature of 450°C or higher and 200000 hours for pipeline components. Hence, the decision has been made to reuse the arrangement of the existing turbine: a four-cylinder turbine unit comprising a high-pressure cylinder (HPC), two intermediate pressure cylinders (IPC-1 & 2), and a low-pressure cylinder (LPC). The flow path in the new turbine will have active blading in LPC and IPC-1. The information is also presented on the use of the existing foundations, the fact that the overall dimensions of the turbine unit compartment are not changed, the selection of the new turbine type, and the solutions adopted on the basis of this information as to LPC blading, steam admission type, issues associated with thermal displacements, etc.
Landman, Annemarie; Nieuwenhuys, Arne; Oudejans, Raôul R D
2016-07-01
We explored the impact of professional experience and personality on police officers' shooting performance under pressure. We recruited: (1) regular officers, (2) officers wanting to join a specialised arrest unit (AU) (expected to possess more stress-resistant traits; pre-AU) and (3) officers from this unit (expected to also possess more professional experience; AU) (all male). In Phase 1, we determined personality traits and experience. In Phase 2, state anxiety, shot accuracy, decision-making (shoot/don't shoot), movement speed and gaze behaviour were measured while officers performed a shooting test under low and high pressure. Results indicate minimal differences in personality among groups and superior performance of AU officers. Regression analyses showed that state anxiety and shooting performance under high pressure were first predicted by AU experience and second by certain personality traits. Results suggest that although personality traits attenuate the impact of high pressure, it is relevant experience that secures effective performance under pressure. Practitioner Summary: To obtain information for police selection and training purposes, we let officers who differed in personality and experience execute a shooting test under low and high pressure. Outcomes indicate that experience affected anxiety and performance most strongly, while personality traits of thrill- and adventure-seeking and self-control also had an effect.
ERIC Educational Resources Information Center
Musambira, George; Collins, Steven; Brown, Tim; Voss, Kimberly
2012-01-01
Although communication program faculty have traditionally not enjoyed large grants for research, administrators are pressuring them to garner external funding. This article examines the success rate of securing external funding that communication administrators reported for their units. Results show that while the pressure has increased on most…
[Design of blood-pressure parameter auto-acquisition circuit].
Chen, Y P; Zhang, D L; Bai, H W; Zhang, D A
2000-02-01
This paper presents the realization and design of a kind of blood-pressure parameter auto-acquisition circuit. The auto-acquisition of blood-pressure parameter controlled by 89C2051 single chip microcomputer is accomplished by collecting and processing the driving signal of LCD. The circuit that is successfully applied in the home unit of telemedicine system has the simple and reliable properties.
de Alba, María; Montiel, Raquel; Bravo, Daniel; Gaya, Pilar; Medina, Margarita
2012-06-01
The effect of high pressure (HP) on Salmonella Enteritidis in sliced dry-cured ham stored under temperature abuse (8°C) during 60d was investigated. After treatment, reductions of S. Enteritidis were 1.06, 2.54 and 4.32 log units in ham treated at 400, 500 and 600MPa for 5min at 12°C, compared to non-pressurized samples. After 60d, counts of S. Enteritidis in ham treated at 400 and 500MPa were 2.56 and 2.66 log units lower than in non-treated ham, whereas the pathogen was only detected after enrichment in ham treated at 600MPa. Lipid oxidation increased with storage and pressurization, whereas total free amino acid contents were similar in HP and control samples after 60d. Dry-cured ham treated at the highest pressures exhibited lower shear resistance, whereas the maximum force to compress the sample was slightly changed. Color (L*, a* and b*) varied with pressurization and storage. Changes induced by HP in dry-cured ham were attenuated during storage. Copyright © 2012 Elsevier Ltd. All rights reserved.
Pre-production Test Report for Transformer Abort Sensing and Control Unit.
The purpose of the report is to describe the test equipment and procedure required for the pre-production testing of a transformer, pressure switch excitation, abort sensing and control unit. (Author)
Modified laminar flow biological safety cabinet.
McGarrity, G J; Coriell, L L
1974-10-01
Tests are reported on a modified laminar flow biological safety cabinet in which the return air plenum that conducts air from the work area to the high efficiency particulate air filters is under negative pressure. Freon gas released inside the cabinet could not be detected outside by a freon gas detection method capable of detecting 10(-6) cc/s. When T3 bacteriophage was aerosolized 5 cm outside the front opening in 11 tests, no phage could be detected inside the cabinet with the motor-filter unit in operation. An average of 2.8 x 10(5) plaque-forming units (PFU)/ft(3) (ca. 0.028 m(3)) were detected with the motor-filter unit not in operation, a penetration of 0.0%. Aerosolization 5 cm inside the cabinet yielded an average of 10 PFU/ft(3) outside the cabinet with the motor-filter unit in operation and an average of 4.1 x 10(5) PFU/ft(3) with the motor-filter unit not in operation, a penetration of 0.002%. These values are the same order of effectiveness as the positive-pressure laminar flow biological safety cabinets previously tested. The advantages of the negative-pressure return plenum design include: (i) assurance that if cracks or leaks develop in the plenum it will not lead to discharge of contaminated air into the laboratory; and (ii) the price is lower due to reduced manufacturing costs.
Theory and application of drilling fluid hydraulics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Whittaker, A.
1985-01-01
The objectives of this book are (1) to serve as a reasonably comprehensive text on the subject of drilling hydraulics and (2) to provide the field geologist with a quick reference to drilling hydraulics calculations. Chapter 1 introduces the basic principles of fluid properties, and Chapter 2 presents the general principles of fluid hydraulics. Chapters 3 through 10 analyze specific hydraulic considerations of the drilling process, such as viscometric measurements, pressure losses, swab and surge pressures, cuttings transport and hydraulic optimization. The units and nomenclature are consistent throughout the manual. Equations are given generally in consistent S.I. units; some commonmore » expressions are also given in oilfield units. Nomenclature is explained after every equation when necessary, and a comprehensive list of the nomenclature used is given in Appendix A. Units are listed in Appendix B. In Appendix C, all the important equations are given in both S.I. and oilfield units. Appendix D contains example hydraulics calculations.« less
Mehta, Chitra; George, Joby V; Mehta, Yatin; Wangmo, Namgyal
2015-08-01
Pressure ulcers is a frequent problem in hospitalized patients. Several prevalence studies have been conducted across the globe. Little information is available regarding prevalence of pressure ulcers in India. The aim was to identify the prevalence of pressure ulcers in one of the tertiary hospital in northern India and the factors associated with its development. A cross sectional point prevalence study. European Pressure Ulcer Advisory Panel (EPUAP) data collection form. Ethics approval was obtained prior to start of the study. Total of 358 patients were enrolled in the study. All patients above 18 years of age admitted in intensive care units and wards were included in the study. Patients admitted in emergency, day care, coronary care unit were excluded because of their short duration of hospital stay (varies from 24 to 72 h usually). All patients admitted before midnight on the predetermined day were included. The Braden scale was used to identify the risk of developing pressure ulcers. European Pressure ulcer advisory panel (EPUAP) minimum data set was used to collect prevalence data. The overall prevalence rate was 7.8%.The sacrum and heel were more commonly affected. Grade III pressure ulcers were the most common (42.8%). The pressure ulcer prevalence rate in our hospital was lower than that published in international studies. Severe forms of pressure ulcers were commonly encountered This data provides background information that may help us in developing protocols for applying effective practices for prevention of pressure ulcers. Copyright © 2015 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.
1984-01-01
policy hut much less so than in the United States. TRADE UNIONS Drawing a distinction between political parties and a pressure group such as trade...policy issues. The Campaign for Democratic Socialism, a pressure group against unilateral disarmament, was set up to counter unionist unilateral
75 FR 8114 - Pressure Sensitive Plastic Tape From Italy
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-23
... INTERNATIONAL TRADE COMMISSION [Investigation No. AA1921-167 (Third Review)] Pressure Sensitive Plastic Tape From Italy AGENCY: United States International Trade Commission. ACTION: Revised schedule for the subject review. DATES: Effective Date: February 16, 2010. FOR FURTHER INFORMATION CONTACT: Edward...
Perioperative factors associated with pressure ulcer development after major surgery.
Kim, Jeong Min; Lee, Hyunjeong; Ha, Taehoon; Na, Sungwon
2018-02-01
Postoperative pressure ulcers are important indicators of perioperative care quality, and are serious and expensive complications during critical care. This study aimed to identify perioperative risk factors for postoperative pressure ulcers. This retrospective case-control study evaluated 2,498 patients who underwent major surgery. Forty-three patients developed postoperative pressure ulcers and were matched to 86 control patients based on age, sex, surgery, and comorbidities. The pressure ulcer group had lower baseline hemoglobin and albumin levels, compared to the control group. The pressure ulcer group also had higher values for lactate levels, blood loss, and number of packed red blood cell ( p RBC) units. Univariate analysis revealed that pressure ulcer development was associated with preoperative hemoglobin levels, albumin levels, lactate levels, intraoperative blood loss, number of p RBC units, Acute Physiologic and Chronic Health Evaluation II score, Braden scale score, postoperative ventilator care, and patient restraint. In the multiple logistic regression analysis, only preoperative low albumin levels (odds ratio [OR]: 0.21, 95% CI: 0.05-0.82; P < 0.05) and high lactate levels (OR: 1.70, 95% CI: 1.07-2.71; P < 0.05) were independently associated with pressure ulcer development. A receiver operating characteristic curve was used to assess the predictive power of the logistic regression model, and the area under the curve was 0.88 (95% CI: 0.79-0.97; P < 0.001). The present study revealed that preoperative low albumin levels and high lactate levels were significantly associated with pressure ulcer development after surgery.
Use of SI Metric Units Misrepresented in College Physics Texts.
ERIC Educational Resources Information Center
Hooper, William
1980-01-01
Summarizes results of a survey that examined 13 textbooks claiming to use SI units. Tables present data concerning the SI and non-SI units actually used in each text in discussion of fluid pressure and thermal energy, and data concerning which texts do and do not use SI as claimed. (CS)
STS-31: APU Controller Removal
NASA Technical Reports Server (NTRS)
1990-01-01
The launch April 10 of the STS-31 was scrubbed at T-4 minutes due to a faulty valve in auxiliary power unit (APU) number one. The auxiliary power unit is a hydrazine-fueled, turbine-driven power unit that generates mechanical shaft power to drive a hydraulic pump that produces pressure for the orbiter's hydraulic system. This video shows the removal of the STS-31's auxiliary power unit (APU).
Direct condensation refrigerant recovery and restoration system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grant, D.C.H.
1992-03-10
This patent describes a refrigerant recovery and purification system for removing gaseous refrigerant from a disabled refrigeration unit, cleaning the refrigerant of contaminants, and converting the gaseous refrigerant to a liquid state for storage. It comprises a low pressure inlet section; a high pressure storage section; the low pressure inlet section comprising: an oil and refrigerant gas separator, including a separated oil removal means, first conduit means for connecting an inlet of the separator to the disabled refrigerant unit, a slack-sided accumulator, second conduit means connecting the separator to the slack-sided accumulator, a reclaim condenser, third conduit means connecting themore » separator and the reclaim condenser in series, an evaporator coil in the reclaim condenser connectable to a conventional operating refrigeration system for receiving a liquid refrigerant under pressure for expansion therein, the evaporator coil forming a condensing surface for condensing the refrigerant gas at near atmospheric pressure in the condenser, a liquid receiver, a reclaimed refrigerant storage tank, fourth conduit means further connecting the liquid receiver in series with the reclaim condenser, downstream thereof, means between the reclaim condenser and the liquid receiver.« less
Control device for prosthetic urinary sphincter cuff
NASA Technical Reports Server (NTRS)
Reinicke, Robert H. (Inventor)
1983-01-01
A device for controlling flow of fluid to and from a resilient inflatable cuff implanted about the urethra to control flow of urine therethrough. The device comprises a flexible bulb reservoir and a control unit that includes a manually operated valve that opens automatically when the bulb is squeezed to force fluid into the cuff for closing the urethra. The control unit also includes a movable valve seat member having a relatively large area exposed to pressure of fluid in a chamber that is connected to the cuff and which moves to a position in which the valve member is unseated by an abutment when fluid pressure in the chamber exceeds a predetermined value to thereby relieve excess fluid pressure in the cuff. The arrangement is such that the valve element is held closed against the seat member by the full differential in fluid pressures acting on both sides of the valve element until the seat member is moved away from the valve element to thus insure positive closing of the valve element until the seat member is moved out of engagement with the valve element by excess pressure differential.
NASA Astrophysics Data System (ADS)
Nikkanen, T.; Schmidt, W.; Harri, A.-M.; Genzer, M.; Hieta, M.; Haukka, H.; Kemppinen, O.
2015-10-01
Finnish Meteorological Institute (FMI) has developed a novel kind of pressure and humidity instrument for the Schiaparelli Mars lander, which is a part of the ExoMars 2016 mission of the European Space Agency (ESA) [1]. The DREAMS-P pressure instrument and DREAMS-H humidity instrument are part of the DREAMS science package on board the lander. DREAMS-P (seen in Fig. 1 and DREAMS-H were evolved from earlier planetary pressure and humidity instrument designs by FMI with a completely redesigned control and data unit. Instead of using the conventional approach of utilizing a space grade processor component, a commercial off the shelf microcontroller was selected for handling the pressure and humidity measurements. The new controller is based on the Freescale MC9S12XEP100 16-bit automotive microcontroller. Coordinated by FMI, a batch of these microcontroller units (MCUs) went through a custom qualification process in order to accept the component for spaceflight on board a Mars lander.
1988-11-01
for this age group included improved roadway safety, reducing the misuse of alcohol and drugs, changing values and social pressures regarding...The exact causes of suicide are uncl]ear. Certainly societv’s exoectations exert a great deal of pressure on this age group . This oressure mav manifest...population that may be useful could be derived from the PatientAdministration System and Biostatistical Activity or by conducting focused group studies
[An automatic system controlled by microcontroller for carotid sinus perfusion].
Yi, X L; Wang, M Y; Fan, Z Z; He, R R
2001-08-01
To establish a new method for controlling automatically the carotid perfusion pressure. A cheap practical automatic perfusion unit based on AT89C2051 micro controller was designed. The unit, LDB-M perfusion pump and the carotid sinus of an animal constituted an automatic perfusion system. This system was able to provide ramp and stepwise updown perfusion pattern and has been used in the research of baroreflex. It can insure the precision and reproducibility of perfusion pressure curve, and improve the technical level in corresponding medical field.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Riess, R.
Chosen for this description of the selected Kraftwerk Union (KWU) pressurized water reactor units were Obrigheim (KWO, 345 MW(e)), Stade (KKS, 662 (MW(e)), Borselle (KCB, 477 MW(e)), and Biblis (KWB-A, 1204 MW(e)). The experience at these plants shows that with a special startup procedure and a proper chemical control of the primary heat transport system that influences general corrosion, selective types of corrosion, corrosion product activity transport and resulting contamination, and radiation-induced decomposition, KWU units have no basic problems.
Aerodynamic Heat-Power Engine Operating on a Closed Cycle
NASA Technical Reports Server (NTRS)
Ackeret, J.; Keller, D. C.
1942-01-01
Hot-air engines with dynamic compressors and turbines offer new prospects of success through utilization of units of high efficiencies and through the employment of modern materials of great strength at high temperature. Particular consideration is given to an aerodynamic prime mover operating on a closed circuit and heated externally. Increase of the pressure level of the circulating air permits a great increase of limit load of the unit. This also affords a possibility of regulation for which the internal efficiency of the unit changes but slightly. The effect of pressure and temperature losses is investigated. A general discussion is given of the experimental installation operating at the Escher Wyss plant in Zurich for a considerable time at high temperatures.
New method to assess the water vapour permeance of wound coverings.
Jonkman, M F; Molenaar, I; Nieuwenhuis, P; Bruin, P; Pennings, A J
1988-05-01
A new method for assessing the permeability to water vapour of wound coverings is presented, using the evaporimeter developed by Nilsson. This new method combines the water vapour transmission rate (WVTR) and the vapour pressure difference across a wound covering in one absolute measure: the water vapour permeance (WVP). The WVP of a wound covering is the steady flow (g) of water vapour per unit (m2) area of surface in unit (h) time induced by unit (kPa) vapour pressure difference, g.m-2.h-1.kPa-1. Since the WVP of a wound covering is a more accurate measure for the permeability than the WVTR is, it facilitates the prediction of the water exchange of a wound covering in clinical situations.
Wang, Shu-Ling; Chuang, Pao-Yu; Su, Wan-Chuan
2018-06-01
Pressure injuries increase the cost of medical care and prolong hospitalization. The incidence of pressure injury at the target coronary care unit (CCU) from January to August 2016 was 1.1%, which was significantly higher than the 0.4% defined in the 2015 Taiwan Clinical Performance Indicators (TCPI) system. Medical device related pressure injury (MDRPI) accounted for 73.1% of the pressure injuries (incidence: 0.8%). The main causes of the high incidence of MDRPI were: (1) inadequate decompression dressing and restraint equipment, (2) incomplete implementation of prevention interventions in the CCU, (3) inadequate knowledge of MDRPI prevention among nurses, (4) deficient standards for preventing MDRPI, (5) ineffective MDRPI-related education, and (6) insufficient auditing frequencies. To reduce the incidence of MDRPI in the target CCU to 0.4% or less. Promote a seed-teacher system and a care bundle that "increased skin tolerance, decompression, medical dressing, change, and removal" using education, the adoption of PE-foam binding gloves, and regular audits. The incidence of MDRPI was reduced from 0.8% to 0.3% between October 2016 and April 2017 and further reduced to 0.1% during the maintenance phase between May and July 2017. The results indicate that the improvement program effectively reduced the incidence of MDRPI and thus increased the quality of nursing care. Therefore, the use of a care bundles should be promoted in intensive care units.
Pressure-volume relationships and elastance in the knee joint of the dog.
Nade, S; Newbold, P J
1984-12-01
This study has investigated changes in intra-articular hydrostatic pressure in the knee joints of normal dogs in response to continuous and stepwise infusions of fluids. The relationship between pressure and volume in the joint was examined over the pressure range of -8 to +50 mmHg, and also at much higher pressures often associated with joint disease or injury. The effects of joint angle and dog weight on the pressure-volume relationship and on elastance of the dogs' knees were also examined. With liquid paraffin B.P. the pressure was found to increase more with each unit volume infused at subatmospheric pressures than at pressures around atmospheric, and increased more again at higher pressures. The pressure-volume curve with saline infusions was affected by egress of fluid from the joint at supra-atmospheric pressure. Above +5 mmHg the rise in pressure per unit volume infused was less than that for paraffin at the same volume. Elastance and compliance of the normal joint capsule were calculated from the pressure-volume data. Elastance was high at subatmospheric pressures, decreased rapidly as atmospheric pressure was approached and rose as a linear function of pressure above 12 mmHg. The biphasic shape of the elastance-pressure curve is discussed, and explanations for the shape are suggested. After intra-articular pressure in the knee was raised by infusion of paraffin oil the joint was moved through the range of positions from 125 deg extension to 50 deg flexion. Intra-articular pressure did not change across the range 125-110 deg. However, increasing the angle of flexion from 110 to 50 deg resulted in a rise in pressure which became steeper for each volume increment. Increasing intra-articular fluid volume caused a decrease in the total range of movement of the joint. The pressure-volume curves measured at extended angles of 110, 125 and 140 deg, where the starting pressures were subatmospheric, were the same. At flexed joint positions of 80 and 50 deg, where the starting pressures were supra-atmospheric, the pressure-volume curves became steeper with greater flexion. Elastance of the joint tissues increased with flexion. The elastance at each joint angle depended also on the volume or pressure. Significant differences were found to exist between pressure-volume curves for three groups of animals of different weight.(ABSTRACT TRUNCATED AT 400 WORDS)
Liquid propellant thermal conditioning system test program
NASA Technical Reports Server (NTRS)
Bullard, B. R.
1972-01-01
Results are presented from more than 1500 hours of testing on a liquid hydrogen thermal conditioning unit. Test parameters included: mixer and vent flow rates; tank size; ullage volume; pressurant gas; pressurant temperature; pressure level; and heat rate. Gaseous hydrogen and helium were used as pressurants. Analytical models were developed to correlate the test data and relate the performance to that anticipated in zero gravity. Experimental and theoretical results are presented which relate the variables controlling vapor condensation at a moving interface.
Design and Testing of Suit Regulator Test Rigs
NASA Technical Reports Server (NTRS)
Campbell, Colin
2010-01-01
The next generation space suit requires additional capabilities for controlling and adjusting internal pressure compared to that of historical designs. Next generation suit pressures will range from slight pressure, for astronaut prebreathe comfort, to hyperbaric pressure levels for emergency medical treatment of decompression sickness. In order to test these regulators through-out their development life cycle, novel automated test rigs are being developed. This paper addresses the design philosophy, performance requirements, physical implementation, and test results with various units under test.
NASA Tech Briefs, February 2012
NASA Technical Reports Server (NTRS)
2012-01-01
This issue contains the following briefs: (1) Optical Comb from a Whispering Gallery Mode Resonator for Spectroscopy and Astronomy Instruments Calibration (2) Real-Time Flight Envelope Monitoring System (3) Nemesis Autonomous Test System (4) Mirror Metrology Using Nano-Probe Supports (5) Automated Lab-on-a-Chip Electrophoresis System (6) Techniques for Down-Sampling a Measured Surface Height Map for Model Validation (7) Multi-Component, Multi-Point Interferometric Rayleigh/Mie Doppler Velocimeter (8) Frequency to Voltage Converter Analog Front-End Prototype (9) Dust-Tolerant Intelligent Electrical Connection System (10) Gigabit Ethernet Asynchronous Clock Compensation FIFO (11) High-Speed, Multi-Channel Serial ADC LVDS Interface for Xilinx Virtex-5 FPGA (12) Glovebox for GeoLab Subsystem in HDU1-PEM (13) Modified Process Reduces Porosity when Soldering in Reduced Gravity Environments (14) Use of Functionalized Carbon Nanotubes for Covalent Attachment of Nanotubes to Silicon (15) Flexible Plug Repair for Shuttle Wing Leading Edge (16) Three Dimensionally Interlinked, Dense, Solid Form of Single-Walled CNT Ropes (17) Axel Robotic Platform for Crater and Extreme Terrain Exploration (18) Site Tamper and Material Plow Tool - STAMP (19) Magnetic Interface for Segmented Mirror Assembly (20) Transpiration-Cooled Spacecraft-Insulation-Repair Fasteners (21) Fluorescence-Based Sensor for Monitoring Activation of Lunar Dust (22) Aperture Ion Source (23) Virtual Ultrasound Guidance for Inexperienced Operators (24) Model-Based Fault Diagnosis: Performing Root Cause and Impact Analyses in Real Time (25) Interactive Schematic Integration Within the Propellant System Modeling Environment (26) Magnetic and Electric Field Polarizations of Oblique Magnetospheric Chorus Waves (27) Variable Sampling Mapping.
75 FR 26273 - Certain Seamless Carbon and Alloy Steel Standard, Line, and Pressure Pipe From China
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-11
... certain seamless carbon and alloy steel standard, line, and pressure pipe (``seamless SLP pipe... China of seamless SLP pipe, and that such products are being sold in the United States at less than fair...
Distributed Autonomous Control Action Based on Sensor and Mission Fusion
2005-09-01
programmable control algorithm driven by the readings of two pressure switch sensors located on either side of the valve unit. Thus, a micro-controller...and Characterization The process of leak detection and characterization must be accomplished with a set of pressure switch sensors. This sensor...economically supplementing existing widely used pressure switch type sensors which are characterized by prohibitively long inertial lag responses
Management of intracerebral pressure in the neurosciences critical care unit.
Marshall, Scott A; Kalanuria, Atul; Markandaya, Manjunath; Nyquist, Paul A
2013-07-01
Management of intracranial pressure in neurocritical care remains a potentially valuable target for improvements in therapy and patient outcomes. Surrogate markers of increased intracranial pressure, invasive monitors, and standard therapy, as well as promising new approaches to improve cerebral compliance are discussed, and a current review of the literature addressing this metric in neuroscience critical care is provided. Published by Elsevier Inc.
Coleman wearing electrodes in the Node 1
2011-01-20
ISS026-E-018798 (20 Jan. 2011) --- NASA astronaut Catherine (Cady) Coleman, Expedition 26 flight engineer, is pictured in the Unity node of the International Space Station. Coleman is wearing electrodes, a Holter Monitor 2 (HM2) for recording Electrocardiogram (ECG), a European Space Agency (ESA) Cardio pressure / Blood Pressure unit to continuously monitor blood pressure and two Actiwatches (hip/waist and ankle) for monitoring activity levels.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chattopadhyay, S., E-mail: suman.mech09@gmail.com; Mondal, P., E-mail: mondal.pradip87@gmail.com; Ghosh, S., E-mail: sudipghosh.becollege@gmail.com
Thermal performance analysis and sizing of a biomass gasification based combined power and refrigeration plant (CPR) is reported in this study. The plant is capable of producing 100 kWe of electrical output while simultaneously producing a refrigeration effect, varying from 28-68 ton of refrigeration (TR). The topping gas turbine cycle is an indirectly heated all-air cycle. A combustor heat exchanger duplex (CHX) unit burns producer gas and transfer heat to air. This arrangement avoids complex gas cleaning requirements for the biomass-derived producer gas. The exhaust air of the topping GT is utilized to run a bottoming ammonia absorption refrigeration (AAR)more » cycle via a heat recovery steam generator (HRSG), steam produced in the HRSG supplying heat to the generator of the refrigeration cycle. Effects of major operating parameters like topping cycle pressure ratio (r{sub p}) and turbine inlet temperature (TIT) on the energetic performance of the plant are studied. Energetic performance of the plant is evaluated via energy efficiency, required biomass consumption and fuel energy savings ratio (FESR). The FESR calculation method is significant for indicating the savings in fuel of a combined power and process heat plant instead of separate plants for power and process heat. The study reveals that, topping cycle attains maximum power efficiency of 30%in pressure ratio range of 8-10. Up to a certain value of pressure ratio the required air flow rate through the GT unit decreases with increase in pressure ratio and then increases with further increase in pressure ratio. The capacity of refrigeration of the AAR unit initially decreases up to a certain value of topping GT cycle pressure ratio and then increases with further increase in pressure ratio. The FESR is found to be maximized at a pressure ratio of 9 (when TIT=1100°C), the maximum value being 53%. The FESR is higher for higher TIT. The heat exchanger sizing is also influenced by the topping cycle pressure ratio and GT-TIT.« less
Measurements and Computations of Second-Mode Instability Waves in Three Hypersonic Wind Tunnels
NASA Technical Reports Server (NTRS)
Berridge, Dennis C.; Casper, Katya M.; Rufer, Shann J.; Alba, Christopher R.; Lewis, Daniel R.; Beresh, Steven J.; Schneider, Steven P.
2010-01-01
High-frequency pressure-fluctuation measurements were made in AEDC Tunnel 9 at Mach 10 and the NASA Langley 15-Inch Mach 6 and 31-Inch Mach 10 tunnels. Measurements were made on a 7deg-half-angle cone model. Pitot measurements of freestream pressure fluctuations were also made in Tunnel 9 and the Langley Mach-6 tunnel. For the first time, second-mode waves were measured in all of these tunnels, using 1-MHz-response pressure sensors. In Tunnel 9, second-mode waves could be seen in power spectra computed from records as short as 80 micro-s. The second-mode wave amplitudes were observed to saturate and then begin to decrease in the Langley tunnels, indicating wave breakdown. Breakdown was estimated to occur near N approx. equals 5 in the Langley Mach-10 tunnel. The unit-Reynolds-number variations in the data from Tunnel 9 were too large to see the same processes. In Tunnel 9, the measured transition locations were found to be at N = 4.5 using thermocouples, and N = 5.3 using 50-kHz-response pressure sensors. What appears to be a very long transitional region was observed at a unit Reynolds number of 13.5 million per meter in Tunnel 9. These results were consistent with the high-frequency pressure fluctuation measurements. High-frequency pressure fluctuation measurements indicated that transition did occur in the Langley Mach-6 tunnel, but the location of transition was not precisely determined. Unit Reynolds numbers in the Langley Mach-10 tunnel were too low to observe transition. More analysis of this data set is expected in the future.
Pressure Injury Knowledge in Critical Care Nurses.
Miller, Donna M; Neelon, Lisa; Kish-Smith, Kathleen; Whitney, Laura; Burant, Christopher J
The purpose of this study was to identify pressure injury knowledge in critical care nurses related to prevention and staging following multimodal education initiatives. Postintervention descriptive study. The sample comprised 32 RNs employed in medical intensive care/coronary intensive care or surgical intensive care units. The study setting was a 237-bed Veterans Affairs acute care hospital in the Midwestern United States. Critical care RNs were asked to participate in this project over a 3-week period following a multimodal 2-year education initiative. Nurses completed the paper version of the 72-item Pieper-Zulkowski Pressure Ulcer Knowledge Test (PZ-PUKT) to determine pressure injury knowledge level. Calculated mean cumulative scores and subscores for items related to prevention and staging, respectively. Pearson correlations were used to examine associations between nursing staff characteristics and the PZ-PUKT prevention and staging scores. The cumulative score on the PZ-PUKT was 51.66 (72%); nurses with 5 to 10 years' experience had a higher mean score than nurses with experiences of 20 years or more (mean ± SD = 54.25 ± 4.37 vs 49.5 ± 7.12), but the difference was not statistically significant. Nurses scored higher on the staging system-related items as compared to the prevention-related items (81% vs 70%). Nurses achieved higher staging subscale scores if they were younger (r =-0.41, P < .05), had less experience (r =-0.43, P < .05), and if they worked in the medical intensive care unit (r = 0.37, P < .05). Study findings indicate gaps in knowledge related to pressure injury practice; participants had greater knowledge of staging rather than prevention. Cumulative and subscale findings can be used to direct educational efforts needed to improve and maintain an effective pressure injury prevention program.
Valencia, Mauricio; Ferrer, Miquel; Farre, Ramon; Navajas, Daniel; Badia, Joan Ramon; Nicolas, Josep Maria; Torres, Antoni
2007-06-01
The aspiration of subglottic secretions colonized by bacteria pooled around the tracheal tube cuff due to inadvertent deflation (<20 cm H2O) of the cuff plays a relevant role in the pathogenesis of ventilator-associated pneumonia. We assessed the efficacy of an automatic, validated device for the continuous regulation of tracheal tube cuff pressure in preventing ventilator-associated pneumonia. Prospective randomized controlled trial. Respiratory intensive care unit and general medical intensive care unit. One hundred and forty-two mechanically ventilated patients (age, 64 +/- 17 yrs; Acute Physiology and Chronic Health Evaluation II score, 18 +/- 6) without pneumonia or aspiration at admission. Within 24 hrs of intubation, patients were randomly allocated to undergo continuous regulation of the cuff pressure with the automatic device (n = 73) or routine care of the cuff pressure (control group, n = 69). Patients remained in a semirecumbent position in bed. The primary end point variable was the incidence of ventilator-associated pneumonia. Main causes for intubation were decreased consciousness (43, 30%) and exacerbation of chronic respiratory diseases (38, 27%). Cuff pressure <20 cm H2O was more frequently observed in the control than the automatic group (45.3 vs. 0.7% determinations, p < .001). However, the rate of ventilator-associated pneumonia with clinical criteria (16, 22% vs. 20, 29%) and microbiological confirmation (11, 15% vs. 10, 15%), the distribution of early and late onset, the causative microorganisms, and intensive care unit (20, 27% vs. 16, 23%) and hospital mortality (30, 41% vs. 23, 33%) were similar for the automatic and control groups, respectively. Cuff pressure is better controlled with the automatic device. However, it did not result in additional benefits to the semirecumbent position in preventing ventilator-associated pneumonia.
Anisotropic compressibility of the coordination polymer emim[Mn(btc)].
Madsen, Solveig R; Moggach, Stephen A; Overgaard, Jacob; Brummerstedt Iversen, Bo
2016-06-01
The effect of pressure on the crystal structure of a coordination polymer, emim[Mn(II)(btc)] (emim = 1-ethyl,3-methyl imidazolium cation, btc = 1,3,5-benzene-tricarboxylate), was investigated with single-crystal X-ray diffraction. At 4.3 GPa the unit-cell volume had decreased by 14% compared with ambient conditions. The unit-cell contraction is highly anisotropic, with the a- and b-axes decreasing by 5.5 and 9.5%, respectively, and the c-axis compressing a mere 0.25% up to 1.7 GPa followed by a 0.2% expansion between 1.7 and 4.3 GPa. The 0.2% increase in length of the c-axis in this interval happens above the quasi-hydrostatic limit of the pressure-transmitting medium and therefore it might be a consequence of strain gradients. Under ambient conditions, two MnO6 units are connected by two carboxylate ligands to form dimeric units. On increasing pressure, a non-bonded O atom from a bridging carboxylate group approaches the Mn atom, with the Mn-O distance decreasing from 2.866 (1) Å at 0.3 GPa to 2.482 (6) Å at 4.3 GPa, increasing the coordination environment of the Mn ion from six- to seven-coordinated.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-21
...; Zion Nuclear Power Station, Units 1 and 2; Exemption From Certain Security Requirements 1.0 Background Zion Nuclear Power Station (ZNPS or Zion), Unit 1, is a Westinghouse 3250 MWt Pressurized Water Reactor... activities in nuclear power reactors against radiological sabotage,'' paragraph (b)(1) states, ``The licensee...
Rotating diffuser for pressure recovery in a steam cooling circuit of a gas turbine
Eldrid, Sacheverel Q.; Salamah, Samir A.; DeStefano, Thomas Daniel
2002-01-01
The buckets of a gas turbine are steam-cooled via a bore tube assembly having concentric supply and spent cooling steam return passages rotating with the rotor. A diffuser is provided in the return passage to reduce the pressure drop. In a combined cycle system, the spent return cooling steam with reduced pressure drop is combined with reheat steam from a heat recovery steam generator for flow to the intermediate pressure turbine. The exhaust steam from the high pressure turbine of the combined cycle unit supplies cooling steam to the supply conduit of the gas turbine.
Black, Joyce; Berke, Christine; Urzendowski, Gail
2012-01-01
The primary objective of this study was to compare facility-acquired pressure ulcer incidence and progression of pressure ulcers present on admission in critically ill patients, using 2 different support surfaces. We completed a comparison cohort study in a surgical intensive care unit (ICU). The study setting was a 12-bed cardiovascular ICU in a university-based hospital in the Midwestern United States. The sample comprised 52 critically ill patients; 31 were placed on low air loss weight-based pressure redistribution-microclimate management system beds and 21 were placed on integrated powered air pressure redistribution beds. Prior to the start of the study, 5 low airloss beds were placed in open rooms in the cardiovascular surgical ICU. Inclusion criteria were anticipated ICU stay of 3 days, and patients did not receive a speciality bed for pulmonary or wound issues. Initial assessment of the patients included risk assessment and prior events that would increase risk for pressure ulcer development such as extended time in operating room, along with skin assessment for existing pressure ulcers. Subjects in both groups had ongoing skin assessment every 3 to 4 days and a subjective evaluation of heel elevation and turning or repositioning by the researcher. Data were collected until the subjects were dismissed from the ICU. Patients admitted to the unit were assigned to open rooms following the usual protocols. The mean length of stay was 7.0 days, with an 8.1-day length of stay for subjects on "low air loss with microclimate management" beds (LAL-MCM) and 6.6 days on the integrated power pressure air redistribution (IP-AR) beds (P = NS). The incidence of pressure ulcers on the buttocks, sacrum, or coccyx was 0% (0/31) on the low air loss bed and 18% (4/21) on the IP-AR bed (P = .046). Five subjects had 6 pressure ulcers on admission. Two pressure ulcers on 2 patients worsened on the integrated power air redistribution beds, which required specialty bed rental costing the facility $4116. No subjects on the low air loss beds experienced worsening of existing pressure ulcer. One patient with a deep tissue injury present on admission improved on the LAL-MCM bed. The IP-AR beds were approximately 7 years old, and the LAL-MCM beds were new. Critically ill subjects placed on low air loss beds with microclimate management in surgical ICUs had a lower pressure ulcer incidence than those placed on integrated powered air pressure redistribution beds. The clinical performance of the IP-AR surfaces may have been influenced by their age.
Development of Emergency Intravehicular Spacesuit (EIS) assembly
NASA Technical Reports Server (NTRS)
1973-01-01
A program was undertaken to develop and test two prototype pressure suits to operate at pressures up to 413 mm Hg (8.0 PSIG). The units were designated Emergency Intravehicular Spacesuits (EIS). Performance requirements, design evolution, testing performed, problems encountered, and final EIS configuration are reported.
Lu, Yunjun; Liu, Cencen; Zhao, Mouming; Cui, Chun; Ren, Jiaoyan
2015-11-04
Phytohemagglutin (PHA), purified from red kidney beans (Phaseolus vulgaris) by Affi-Gel blue affinity chromatography, was subjected to ultrahigh-pressure (UHP) treatment (150, 250, 350, and 450 MPa). The purified PHA lost its hemagglutination activity after 450 MPa treatment and showed less pressure tolerance than crude PHA. However, the saccharide specificity and α-glucosidase inhibition activity of the purified PHA did not change much after UHP treatment. Electrophoresis staining by periodic acid-Schiff (PAS) manifested that the glycone structure of purified PHA remained stable even after 450 MPa pressure treatment. However, electrophoresis staining by Coomassie Blue as well as circular dichroism (CD) and differential scanning calorimetry (DSC) assay proved that the protein unit structure of purified PHA unfolded when treated at 0-250 MPa but reaggregates at 250-450 MPa. Therefore, the hemagglutination activity tends to be affected by the protein unit structure, while the stability of the glycone structure contributed to the remaining α-glucosidase inhibition activity.
Design for pressure regulating components
NASA Technical Reports Server (NTRS)
Wichmann, H.
1973-01-01
The design development for Pressure Regulating Components included a regulator component trade-off study with analog computer performance verification to arrive at a final optimized regulator configuration for the Space Storable Propulsion Module, under development for a Jupiter Orbiter mission. This application requires the pressure regulator to be capable of long-term fluorine exposure. In addition, individual but basically identical (for purposes of commonality) units are required for separate oxidizer and fuel pressurization. The need for dual units requires improvement in the regulation accuracy over present designs. An advanced regulator concept was prepared featuring redundant bellows, all metallic/ceramic construction, friction-free guidance of moving parts, gas damping, and the elimination of coil springs normally used for reference forces. The activities included testing of actual size seat/poppet components to determine actual discharge coefficients and flow forces. The resulting data was inserted into the computer model of the regulator. Computer simulation of the propulsion module performance over two mission profiles indicated satisfactory minimization of propellant residual requirements imposed by regulator performance uncertainties.
NASA Astrophysics Data System (ADS)
Lee, Scott A.
2014-03-01
High-pressure Raman spectroscopy has been used to study the eigenvectors and eigenvalues of the low-frequency vibrational modes of crystalline cytidine at 295 K by evaluating the logarithmic derivative of the vibrational frequency with respect to pressure: 1/ω dω/dP. Crystalline samples of molecular materials such as cytidine have vibrational modes that are localized within a molecular unit (``internal'' modes) as well as modes in which the molecular units vibrate against each other (``external'' modes). The value of the logarithmic derivative is a diagnostic probe of the nature of the eigenvector of the vibrational modes, making high pressure experiments a very useful probe for such studies. Internal stretching modes have low logarithmic derivatives while external as well as internal torsional and bending modes have higher logarithmic derivatives. All of the Raman modes below 200 cm-1 in cytidine are found to have high logarithmic derivatives, consistent with being either external modes or internal torsional or bending modes.
Educating Nurses in the United States about Pressure Injuries.
Ayello, Elizabeth A; Zulkowski, Karen; Capezuti, Elizabeth; Jicman, Wendy Harris; Sibbald, R Gary
2017-02-01
To provide information about the current state of educating nurses about wound care and pressure injuries with recommendations for the future. This continuing education activity is intended for physicians, physician assistants, nurse practitioners, and nurses with an interest in skin and wound care. After participating in this educational activity, the participant should be better able to:1. Discuss the importance of pressure injury education and wound care for nurses and identify the current state of nursing education on the subject. 2. Identify strategies that can be used to put improved wound care and pressure injury education into practice. Wound care nursing requires knowledge and skill to operationalize clinical guidelines. Recent surveys and studies have revealed gaps in nurses' knowledge of wound care and pressure injuries and their desire for more education, both in their undergraduate programs and throughout their careers. Data from baccalaureate programs in the United States can pinpoint areas for improvement in nursing curriculum content. Lifelong learning about wound care and pressure injuries starts with undergraduate nursing education but continues through the novice-to-expert Benner categories that are facilitated by continuing professional development. This article introduces a pressure injury competency skills checklist and educational strategies based on Adult Learning principles to support knowledge acquisition (in school) and translation (into clinical settings). The responsibility for lifelong learning is part of every nurse's professional practice.
NASA Astrophysics Data System (ADS)
Alligné, S.; Nicolet, C.; Béguin, A.; Landry, C.; Gomes, J.; Avellan, F.
2017-04-01
The prediction of pressure and output power fluctuations amplitudes on Francis turbine prototype is a challenge for hydro-equipment industry since it is subjected to guarantees to ensure smooth and reliable operation of the hydro units. The European FP7 research project Hyperbole aims to setup a methodology to transpose the pressure fluctuations induced by the cavitation vortex rope from the reduced scale model to the prototype generating units. A Francis turbine unit of 444MW with a specific speed value of ν = 0.29, is considered as case study. A SIMSEN model of the power station including electrical system, controllers, rotating train and hydraulic system with transposed draft tube excitation sources is setup. Based on this model, a frequency analysis of the hydroelectric system is performed for all technologies to analyse potential interactions between hydraulic excitation sources and electrical components. Three technologies have been compared: the classical fixed speed configuration with Synchronous Machine (SM) and the two variable speed technologies which are Doubly Fed Induction Machine (DFIM) and Full Size Frequency Converter (FSFC).
Li, Guangyan; Connors, Bret A; Schaefer, Ray B; Gallagher, John J; Evan, Andrew P
2017-11-01
In this paper, an extracorporeal shock wave source composed of small ellipsoidal sparker units is described. The sparker units were arranged in an array designed to produce a coherent shock wave of sufficient strength to fracture kidney stones. The objective of this paper was to measure the acoustical output of this array of 18 individual sparker units and compare this array to commercial lithotripters. Representative waveforms acquired with a fiber-optic probe hydrophone at the geometric focus of the sparker array indicated that the sparker array produces a shock wave (P + ∼40-47 MPa, P - ∼2.5-5.0 MPa) similar to shock waves produced by a Dornier HM-3 or Dornier Compact S. The sparker array's pressure field map also appeared similar to the measurements from a HM-3 and Compact S. Compared to the HM-3, the electrohydraulic technology of the sparker array produced a more consistent SW pulse (shot-to-shot positive pressure value standard deviation of ±4.7 MPa vs ±3.3 MPa).
Yang, Lei; Zhou, Weihua; Xue, Kaihua; Wei, Rupeng; Ling, Zheng
2018-05-01
The enormous potential as an alternative energy resource has made natural gas hydrates a material of intense research interest. Their exploration and sample characterization require a quick and effective analysis of the hydrate-bearing cores recovered under in situ pressures. Here a novel Pressure Core Ultrasonic Test System (PCUTS) for on-board analysis of sediment cores containing gas hydrates at in situ pressures is presented. The PCUTS is designed to be compatible with an on-board pressure core transfer device and a long gravity-piston pressure-retained corer. It provides several advantages over laboratory core analysis including quick and non-destructive detection, in situ and successive acoustic property acquisition, and remission of sample storage and transportation. The design of the unique assembly units to ensure the in situ detection is demonstrated, involving the U-type protecting jackets, transducer precession device, and pressure stabilization system. The in situ P-wave velocity measurements make the detection of gas hydrate existence in the sediments possible on-board. Performance tests have verified the feasibility and sensitivity of the ultrasonic test unit, showing the dependence of P-wave velocity on gas hydrate saturation. The PCUTS has been successfully applied for analysis of natural samples containing gas hydrates recovered from the South China Sea. It is indicated that on-board P-wave measurements could provide a quick and effective understanding of the hydrate occurrence in natural samples, which can assist further resource exploration, assessment, and subsequent detailed core analysis.
NASA Astrophysics Data System (ADS)
Yang, Lei; Zhou, Weihua; Xue, Kaihua; Wei, Rupeng; Ling, Zheng
2018-05-01
The enormous potential as an alternative energy resource has made natural gas hydrates a material of intense research interest. Their exploration and sample characterization require a quick and effective analysis of the hydrate-bearing cores recovered under in situ pressures. Here a novel Pressure Core Ultrasonic Test System (PCUTS) for on-board analysis of sediment cores containing gas hydrates at in situ pressures is presented. The PCUTS is designed to be compatible with an on-board pressure core transfer device and a long gravity-piston pressure-retained corer. It provides several advantages over laboratory core analysis including quick and non-destructive detection, in situ and successive acoustic property acquisition, and remission of sample storage and transportation. The design of the unique assembly units to ensure the in situ detection is demonstrated, involving the U-type protecting jackets, transducer precession device, and pressure stabilization system. The in situ P-wave velocity measurements make the detection of gas hydrate existence in the sediments possible on-board. Performance tests have verified the feasibility and sensitivity of the ultrasonic test unit, showing the dependence of P-wave velocity on gas hydrate saturation. The PCUTS has been successfully applied for analysis of natural samples containing gas hydrates recovered from the South China Sea. It is indicated that on-board P-wave measurements could provide a quick and effective understanding of the hydrate occurrence in natural samples, which can assist further resource exploration, assessment, and subsequent detailed core analysis.
Chiari, Paolo; Poli, Marco; Magli, Claudia; Bascelli, Emanuele; Rocchi, Roberto; Bolognini, Silvia; Tartari, Piero; Armuzzi, Roberta; Rossi, Gianna; Peghetti, Angela; Biavati, Catia; Fontana, Mirella; Gazineo, Domenica; Cordella, Simona; Tiozzo, Emanuela; Ciliento, Gaetano; Carta, Giovanna; Taddia, Patrizia
2012-01-01
Multicenter prospective cohort study, to validate the Italian version of the Braden Q scale for the risk of pressure sores in newborns and up to 8 years old children. Children admitted to Intensive care Units (ICU), oncology and neurology/neurosurgery wards are at risk of developing pressure sores. To validate the Italian version of the Braden Q scale for the assessment of the risk of developing pressure sores in children. Children from 21 days to 8 years, admitted to intensive and sub intensive units were recruited. Premature babies, children admitted with a pressure sore and with a story of congenital cardiomiopathy were excluded. In this cohort, multicentre and with repeated measurements study, the first assessment was performed after 24 hours from hospital admission, using the Braden Q Scale (Suddaby's version). The pressure sores were assessed with the Skin assessment Tool and staged according to the National Pressure Ulcer Advisory Panel. RESULTS. On the 157 children 524 observation were conducted. The incidence of pressure sores was 17.2%. Only the analysis on specific subgroups of patients showed a good diagnostic accuracy: 71.4% on children 3-8 years; 85.6% in sub intensive wards. The Braden Q scale may be reliably used and shows a good diagnostic accuracy in children 3-8 years of age admitted to sub-intensive, neurology, oncology and heamatology wards.
Ramírez-Solís, A; Zicovich-Wilson, C M; Hernández-Lamoneda, R; Ochoa-Calle, A J
2017-01-25
The question of the non-magnetic (NM) vs. antiferromagnetic (AF) nature of the ε phase of solid oxygen is a matter of great interest and continuing debate. In particular, it has been proposed that the ε phase is actually composed of two phases, a low-pressure AF ε 1 phase and a higher pressure NM ε 0 phase [Crespo et al., Proc. Natl. Acad. Sci. U. S. A., 2014, 111, 10427]. We address this problem through periodic spin-restricted and spin-polarized Kohn-Sham density functional theory calculations at pressures from 10 to 50 GPa using calibrated GGA and hybrid exchange-correlation functionals with Gaussian atomic basis sets. The two possible configurations for the antiferromagnetic (AF1 and AF2) coupling of the 0 ≤ S ≤ 1 O 2 molecules in the (O 2 ) 4 unit cell were studied. Full enthalpy-driven geometry optimizations of the (O 2 ) 4 unit cells were done to study the pressure evolution of the enthalpy difference between the non-magnetic and both antiferromagnetic structures. We also address the evolution of structural parameters and the spin-per-molecule vs. pressure. We find that the spin-less solution becomes more stable than both AF structures above 50 GPa and, crucially, the spin-less solution yields lattice parameters in much better agreement with experimental data at all pressures than the AF structures. The optimized AF2 broken-symmetry structures lead to large errors of the a and b lattice parameters when compared with experiments. The results for the NM model are in much better agreement with the experimental data than those found for both AF models and are consistent with a completely non-magnetic (O 2 ) 4 unit cell for the low-pressure regime of the ε phase.
Multifaceted bench comparative evaluation of latest intensive care unit ventilators.
Garnier, M; Quesnel, C; Fulgencio, J-P; Degrain, M; Carteaux, G; Bonnet, F; Similowski, T; Demoule, A
2015-07-01
Independent bench studies using specific ventilation scenarios allow testing of the performance of ventilators in conditions similar to clinical settings. The aims of this study were to determine the accuracy of the latest generation ventilators to deliver chosen parameters in various typical conditions and to provide clinicians with a comprehensive report on their performance. Thirteen modern intensive care unit ventilators were evaluated on the ASL5000 test lung with and without leakage for: (i) accuracy to deliver exact tidal volume (VT) and PEEP in assist-control ventilation (ACV); (ii) performance of trigger and pressurization in pressure support ventilation (PSV); and (iii) quality of non-invasive ventilation algorithms. In ACV, only six ventilators delivered an accurate VT and nine an accurate PEEP. Eleven devices failed to compensate VT and four the PEEP in leakage conditions. Inspiratory delays differed significantly among ventilators in invasive PSV (range 75-149 ms, P=0.03) and non-invasive PSV (range 78-165 ms, P<0.001). The percentage of the ideal curve (concomitantly evaluating the pressurization speed and the levels of pressure reached) also differed significantly (range 57-86% for invasive PSV, P=0.04; and 60-90% for non-invasive PSV, P<0.001). Non-invasive ventilation algorithms efficiently prevented the decrease in pressurization capacities and PEEP levels induced by leaks in, respectively, 10 and 12 out of the 13 ventilators. We observed real heterogeneity of performance amongst the latest generation of intensive care unit ventilators. Although non-invasive ventilation algorithms appear to maintain adequate pressurization efficiently in the case of leakage, basic functions, such as delivered VT in ACV and pressurization in PSV, are often less reliable than the values displayed by the device suggest. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Burlaga, L. F.; Ness, N. F.; Belcher, J. W.; Szabo, A.; Isenberg, P. A.; Lee, M. A.
1994-11-01
Five pressure-balanced structures, each with a scale of the order of a few hundredths of an astonomical unit (AU), were identified in two merged interaction regions (MIRs) near 35 AU in the Voyager 2 plasma and magnetic field data. They include a tangential discontinuity, simple and complex magnetic holes, slow correlated variations among the plasma and magnetic field parameters, and complex uncorrelated variations among the parameters. The changes in the magnetic pressure in these events are balanced by changes in the pressure of interstellar pickup protons. Thus the pickup protons probably play a major role in the dynamics of the MIRs. The solar wind proton and electron pressures are relatively unimportant in the MIRs at 35 AU and beyond. The region near 35 AU is transition region: the Sun is the source of the magnetic field, but the interstellar medium in source of pickups protons. Relative to the solar wind proton guyroadius, the thicknesses of the discontinuities and simple magnetic holes observed near 35 AU are at least an order of magnitude greater than those observed at 1 AU. However, the thicknesses of the tangential discontinuity and simple magnetic holes observed near 35 AU (in units of the pickup proton Larmor radius) are comparable to those observed at 1 AU (in units of the solar wind proton gyroradius). Thus the gyroradius of interstellar pickup protons controls the thickness of current sheets near 35 AU. We determine the interstellar pickup proton pressure in the PBSs. Using a model for the pickup proton temperature, we estimate that the average interstellar pickup proton pressure, temperature, and density in the MIRs at 35 AU are (0.53 +/- 0.14) x 10-12 erg/cu cm, (5.8 +/- 0.4) x 106 K and (7 +/- 2) x 10-4/cu cm.
Ford, Clyde D; Lopansri, Bert K; Gazdik, Michaela A; Webb, Brandon; Snow, Gregory L; Hoda, Daanish; Adams, Barbara; Petersen, Finn Bo
2016-10-01
Contaminated surfaces and colonization pressure are risk factors for vancomycin-resistant Enterococcus (VRE) colonization in intensive care units (ICUs). Whether these apply to modern units dedicated to the care of hematologic malignancies and hematopoietic stem cell transplant (HSCT) procedures is unknown. We reviewed the records of 780 consecutive admissions for acute leukemia, autologous HSCT, or allogeneic HSCT in which the patient was at risk for hospital-acquired VRE and underwent weekly surveillance. We also obtained staff and room cultures, observed staff behavior, and performed VRE molecular strain typing on selected isolates. The overall rate of VRE colonization was 11.4 cases/1,000 patient days. Cultures of room surfaces revealed VRE isolates in 10% of terminally cleaned rooms. A prior VRE-colonized room occupant did not increase risk, and paired isolates from 20 patients and prior occupants were indistinguishable on molecular typing in only 1 pair. VRE colonization pressure was significantly associated with acquisition. Cultures of unit personnel and shared equipment were negative except for weighing scales. Observation of unit clinical personnel showed high compliance for hand sanitation and but less so for gowns. Conversely, ancillary staff showed poor compliance. Transmission of VRE from room surfaces seems to be an infrequent event. Encouraging adherence to surveillance, disinfection, and contact isolation protocols may decrease VRE colonization rates. Copyright © 2016. Published by Elsevier Inc.
The turn team: a novel strategy for reducing pressure ulcers in the surgical intensive care unit.
Still, Mary D; Cross, Linda C; Dunlap, Martha; Rencher, Rugenia; Larkins, Elizabeth R; Carpenter, David L; Buchman, Timothy G; Coopersmith, Craig M
2013-03-01
Pressure ulcers cause significant morbidity and mortality in the surgical intensive care unit (SICU). The purpose of this study was to determine if a dedicated team tasked with turning and repositioning all hemodynamically stable SICU patients could decrease the formation of pressure ulcers. A total of 507 patients in a 20-bed SICU in a university hospital were assessed for pressure ulcers using a point prevalence strategy, between December 2008 and September 2010, before and after implementation of a team tasked with turning and repositioning all hemodynamically stable patients every 2 hours around the clock. At baseline, when frequent turning was encouraged but not required, a total of 42 pressure ulcers were identified in 278 patients. After implementation of the turn team, a total of 12 pressure ulcers were identified in 229 patients (p < 0.0001). The preintervention group included 34 stage I and II ulcers and 8 higher stage ulcers. After implementation of the turn team, there were 7 stage I and II ulcers and 5 higher stage ulcers. The average Braden score was 16.5 in the preintervention group and 13.4 in the postintervention group (p = 0.04), suggesting that pressure ulcers were occurring in higher risk patients after implementation of the turn team. A team dedicated to turning SICU patients every 2 hours dramatically decreased the incidence of pressure ulcers. The majority of stage I and stage II ulcers appear to be preventable with an aggressive intervention aimed at pressure ulcer prevention. Copyright © 2013 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
Perioperative factors associated with pressure ulcer development after major surgery
2018-01-01
Background Postoperative pressure ulcers are important indicators of perioperative care quality, and are serious and expensive complications during critical care. This study aimed to identify perioperative risk factors for postoperative pressure ulcers. Methods This retrospective case-control study evaluated 2,498 patients who underwent major surgery. Forty-three patients developed postoperative pressure ulcers and were matched to 86 control patients based on age, sex, surgery, and comorbidities. Results The pressure ulcer group had lower baseline hemoglobin and albumin levels, compared to the control group. The pressure ulcer group also had higher values for lactate levels, blood loss, and number of packed red blood cell (pRBC) units. Univariate analysis revealed that pressure ulcer development was associated with preoperative hemoglobin levels, albumin levels, lactate levels, intraoperative blood loss, number of pRBC units, Acute Physiologic and Chronic Health Evaluation II score, Braden scale score, postoperative ventilator care, and patient restraint. In the multiple logistic regression analysis, only preoperative low albumin levels (odds ratio [OR]: 0.21, 95% CI: 0.05–0.82; P < 0.05) and high lactate levels (OR: 1.70, 95% CI: 1.07–2.71; P < 0.05) were independently associated with pressure ulcer development. A receiver operating characteristic curve was used to assess the predictive power of the logistic regression model, and the area under the curve was 0.88 (95% CI: 0.79–0.97; P < 0.001). Conclusions The present study revealed that preoperative low albumin levels and high lactate levels were significantly associated with pressure ulcer development after surgery. PMID:29441175
NASA Astrophysics Data System (ADS)
Singla, Rohit; Chowdhury, Kanchan
2017-02-01
Specific power consumed in a Linde double column air separation unit (ASU) increases as the quantity of oxygen produced at a given purity is decreased due to the changes of system requirement or market demand. As the plant operates in part load condition, the specific power consumption (SPC) increases as the total power consumption remains the same. In order to mitigate the increase of SPC at lower oxygen production, the operating pressure of high pressure column (HPC) can be lowered by extending the low pressure column (LPC) by a few trays and adding a second reboiler. As the duty of second reboiler in LPC is increased, the recovery of oxygen decreases with a lowering of the HPC pressure. This results in mitigation of the increase of SPC of the plant. A Medium pressure ASU with dual reboiler that produces pressurised gaseous and liquid products of oxygen and nitrogen is simulated in Aspen Hysys 8.6®, a commercial process simulator to determine SPC at varying oxygen production. The effects of reduced pressure of air feed into the cold box on the size of heat exchangers (HX) are analysed. Operation strategy to obtain various oxygen production rates at varying demand is also proposed.
Effects of spaceflight on human calf hemodynamics
NASA Technical Reports Server (NTRS)
Watenpaugh, D. E.; Buckey, J. C.; Lane, L. D.; Gaffney, F. A.; Levine, B. D.; Moore, W. E.; Wright, S. J.; Blomqvist, C. G.
2001-01-01
Chronic microgravity may modify adaptations of the leg circulation to gravitational pressures. We measured resting calf compliance and blood flow with venous occlusion plethysmography, and arterial blood pressure with sphygmomanometry, in seven subjects before, during, and after spaceflight. Calf vascular resistance equaled mean arterial pressure divided by calf flow. Compliance equaled the slope of the calf volume change and venous occlusion pressure relationship for thigh cuff pressures of 20, 40, 60, and 80 mmHg held for 1, 2, 3, and 4 min, respectively, with 1-min breaks between occlusions. Calf blood flow decreased 41% in microgravity (to 1.15 +/- 0.16 ml x 100 ml(-1) x min(-1)) relative to 1-G supine conditions (1.94 +/- 0.19 ml x 100 ml(-1) x min(-1), P = 0.01), and arterial pressure tended to increase (P = 0.05), such that calf vascular resistance doubled in microgravity (preflight: 43 +/- 4 units; in-flight: 83 +/- 13 units; P < 0.001) yet returned to preflight levels after flight. Calf compliance remained unchanged in microgravity but tended to increase during the first week postflight (P > 0.2). Calf vasoconstriction in microgravity qualitatively agrees with the "upright set-point" hypothesis: the circulation seeks conditions approximating upright posture on Earth. No calf hemodynamic result exhibited obvious mechanistic implications for postflight orthostatic intolerance.
Armour-Burton, Teri; Fields, Willa; Outlaw, Lanie; Deleon, Elvira
2013-06-01
Hospital-acquired pressure ulcers are serious clinical complications that can lead to increased length of stay, pain, infection, and, potentially, death. The surgical progressive care unit at Sharp Grossmont Hospital, San Diego, California, developed the multidisciplinary Healthy Skin Project to decrease the prevalence of hospital-acquired pressure ulcers. The previous treatment plan was reviewed and modified according to current evidence-based practice. The project consisted of 3 components: creation of a position for a unit-based wound liaison nurse, staff education, and involvement of the nursing assistants. The wound liaison nurse developed and conducted bimonthly skin audits, which revealed inconsistencies in clinical practice and documentation. Education for the staff was accomplished via a self-learning module, case presentations, and 1-on-1 training. In addition, a pressure ulcer algorithm tool was developed to demonstrate step-by-step wound management and documentation. From Spring 2003 through Summer 2006, the prevalence of hospital-acquired pressure ulcers ranged from 0.0% to 18.92%, with a mean of 4.85%. After implementation of the project, the prevalence decreased to 0.0% for 17 of 20 quarters, through 2011. Prevention and a multidisciplinary approach are effective in reducing the occurrence of hospital-acquired pressure ulcers.
Measures of blood pressure and cognition in dialysis patients
USDA-ARS?s Scientific Manuscript database
There are few reports on the relationship of blood pressure with cognitive function in maintenance dialysis patients. The Cognition and Dialysis Study is an ongoing investigation of cognitive function and its risk factors in six Boston area hemodialysis units. In this analysis, we evaluated the rela...
Code of Federal Regulations, 2010 CFR
2010-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PERIODIC TESTS AND INSPECTIONS Tests and Inspections of Pressure Vessels § 61.10-1 Scope. All pressure vessels aboard ships, mobile offshore drilling units, and barges are subject to periodic inspection. [CGD 68-82, 33 FR 18890, Dec. 18, 1968, as amended...
Competition and Curriculum Diversity in Local Schooling Markets: Theory and Evidence.
ERIC Educational Resources Information Center
Adnett, Nick; Davies, Peter
2000-01-01
Based on conventional economic analysis, increasing competitive pressures on schools should promote greater curricular innovation and diversity. The United Kingdom's experience suggests that market-based reforms can initially create pressures to increase curriculum conformity in local schooling markets. Innovation incentives are greatest for…
USDA-ARS?s Scientific Manuscript database
Scanning electron microscopy (SEM) was utilized to evaluate microstructural changes in intramuscular connective tissue of beef semimembranosus muscle subjected to hydrodynamic pressure processing (HDP). Samples were HDP treated in a plastic container (HDP-PC) or a steel commercial unit (HDP-CU). C...
Thille, Arnaud W.; Lyazidi, Aissam; Richard, Jean-Christophe M.; Galia, Fabrice; Brochard, Laurent
2009-01-01
Objective To compare 13 commercially available, new-generation, intensive-care-unit (ICU) ventilators regarding trigger function, pressurization capacity during pressure-support ventilation (PSV), accuracy of pressure measurements and expiratory resistance. Design and Setting Bench study at a research laboratory in a university hospital. Material Four turbine-based ventilators and nine conventional servo-valve compressed-gas ventilators were tested using a two-compartment lung model. Results Three levels of effort were simulated. Each ventilator was evaluated at four PSV levels (5, 10, 15, and 20 cm H2O), with and without positive end-expiratory pressure (5 cm H2O, Trigger function was assessed as the time from effort onset to detectable pressurization. Pressurization capacity was evaluated using the airway pressure-time product computed as the net area under the pressure-time curve over the first 0.3 s after inspiratory effort onset. Expiratory resistance was evaluated by measuring trapped volume in controlled ventilation. Significant differences were found across the ventilators, with a range of triggering-delay from 42 ms to 88 ms for all conditions averaged (P<.001). Under difficult conditions, the triggering delay was longer than 100 ms and the pressurization was poor with five ventilators at PSV5 and three at PSV10, suggesting an inability to unload patient’s effort. On average, turbine-based ventilators performed better than conventional ventilators, which showed no improvement compared to a 2000 bench comparison. Conclusion Technical performances of trigger function, pressurization capacity and expiratory resistance vary considerably across new-generation ICU ventilators. ICU ventilators seem to have reached a technical ceiling in recent years, and some ventilators still perform inadequately. PMID:19352622
Fonseca-Reyes, Salvador; de Alba-García, Javier García; Parra-Carrillo, José Z; Paczka-Zapata, José Antonio
2003-06-01
To measure the effect on blood pressure readings when a standard cuff is used on patients with arms of a large circumference, and to determine the frequency of arms of a large circumference. Blood pressures were taken in 120 subjects with an arm circumference greater than 33 cm. Also, the arm circumference was determined in 244 patients from a family health unit, and in 216 patients from a hypertension clinic. A mercury sphygmomanometer and two different cuff sizes were used in a random sequence; therefore, 60 patients' blood pressure were first measured with a large cuff, followed by a standard cuff; the opposite sequence was then applied for another 60 patients. With the obtained values and using a regression analysis, the difference in blood pressure overestimation was calculated. Arm circumference measurement percentages were used to determine the frequency of arms of a large circumference. Both systolic and diastolic blood pressures were significantly greater when the standard cuff was used. For every 5 cm increase in arm circumference, starting at 35 cm, a 2-5 mmHg increase in systolic blood pressure, and a 1-3 mmHg increase in diastolic blood pressure was observed. The prevalence of arms with a large circumference in the family medicine unit and hypertension clinic was 42% and 41.8%, respectively. There is an overestimation of blood pressure when a standard cuff is used in obese subjects. The high prevalence of these individuals in our environment, both in the hypertensive and normotensive population, makes it necessary to have on hand different sizes of cuffs for taking blood pressure in order to avoid incorrect decisions.
Thille, Arnaud W; Lyazidi, Aissam; Richard, Jean-Christophe M; Galia, Fabrice; Brochard, Laurent
2009-08-01
To compare 13 commercially available, new-generation, intensive-care-unit (ICU) ventilators in terms of trigger function, pressurization capacity during pressure-support ventilation (PSV), accuracy of pressure measurements, and expiratory resistance. Bench study at a research laboratory in a university hospital. Four turbine-based ventilators and nine conventional servo-valve compressed-gas ventilators were tested using a two-compartment lung model. Three levels of effort were simulated. Each ventilator was evaluated at four PSV levels (5, 10, 15, and 20 cm H2O), with and without positive end-expiratory pressure (5 cm H2O). Trigger function was assessed as the time from effort onset to detectable pressurization. Pressurization capacity was evaluated using the airway pressure-time product computed as the net area under the pressure-time curve over the first 0.3 s after inspiratory effort onset. Expiratory resistance was evaluated by measuring trapped volume in controlled ventilation. Significant differences were found across the ventilators, with a range of triggering delays from 42 to 88 ms for all conditions averaged (P < 0.001). Under difficult conditions, the triggering delay was longer than 100 ms and the pressurization was poor for five ventilators at PSV5 and three at PSV10, suggesting an inability to unload patient's effort. On average, turbine-based ventilators performed better than conventional ventilators, which showed no improvement compared to a bench comparison in 2000. Technical performance of trigger function, pressurization capacity, and expiratory resistance differs considerably across new-generation ICU ventilators. ICU ventilators seem to have reached a technical ceiling in recent years, and some ventilators still perform inadequately.
Alkaline and Acid Phosphatase Activity, pH and Osmotic Pressure of Boar Semen***
King, G. J.; Macpherson, J. W.
1966-01-01
Alkaline phosphatase activity was recorded in forty ejaculates of the sperm rich fraction of boar semen as 9,790 ± 5,250 Klein-Babson-Read units per 100 ml. of seminal plasma. Acid phosphatase activity in the same ejaculates was 681 ± 304 Babson-Read units per 100 ml. of seminal plasma. No alkaline phosphatase activity was detected in the seminal plasma of vasectomized boars. The pH of the sperm rich fractions was 7.69 ± 0.33 and the osmotic pressure was 313.56 ± 7.98 milliosmols. PMID:4226380
Dosimetry analyses of the Ringhals 3 and 4 reactor pressure vessels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kulesza, J.A.; Fero, A.H.; Rouden, J.
2011-07-01
A comprehensive series of neutron dosimetry measurements consisting of surveillance capsules, reactor pressure vessel cladding samples, and ex-vessel neutron dosimetry has been analyzed and compared to the results of three-dimensional, cycle-specific neutron transport calculations for the Ringhals Unit 3 and Unit 4 reactors in Sweden. The comparisons show excellent agreement between calculations and measurements. The measurements also demonstrate that it is possible to perform retrospective dosimetry measurements using the {sup 93}Nb (n,n') {sup 93m}Nb reaction on samples of 18-8 austenitic stainless steel with only trace amounts of elemental niobium. (authors)
Using supercritical fluids to refine hydrocarbons
Yarbro, Stephen Lee
2015-06-09
A system and method for reactively refining hydrocarbons, such as heavy oils with API gravities of less than 20 degrees and bitumen-like hydrocarbons with viscosities greater than 1000 cp at standard temperature and pressure, using a selected fluid at supercritical conditions. A reaction portion of the system and method delivers lightweight, volatile hydrocarbons to an associated contacting unit which operates in mixed subcritical/supercritical or supercritical modes. Using thermal diffusion, multiphase contact, or a momentum generating pressure gradient, the contacting unit separates the reaction products into portions that are viable for use or sale without further conventional refining and hydro-processing techniques.
A new electronic scanner of pressure designed for installation in wind-tunnel models
NASA Technical Reports Server (NTRS)
Coe, C. T.; Parra, G. T.; Kauffman, R. C.
1981-01-01
A new electronic scanner of pressure (ESOP) has been developed by NASA Ames Research Center for installation in wind-tunnel models. An ESOP system includes up to 20 pressure modules, each with 48 pressure transducers, an A/D converter, a microprocessor, a data controller, a monitor unit, and a heater controller. The system is sized so that the pressure modules and A/D converter module can be installed within an average-size model tested in the Ames Aerodynamics Division wind tunnels. This paper describes the ESOP system, emphasizing the main element of the system - the pressure module. The measured performance of the overall system is also presented.
NASA Astrophysics Data System (ADS)
Rau, T. H.
1982-06-01
The MB-3 Tester is an electric motor-driven cabin leakage tester designed to furnish pressurized air to the aircraft at controlled pressures and temperatures during ground pressurization of aircraft cockpits and pressurized compartments. This report provides measured data defining the bioacoustic environments produced by this unit operating at a normal rated/load condition. Near-field data are reported for 37 locations in a wide variety of physical and psychoacoustic measures: overall and band sound pressure levels, C-weighted and A-weighted sound levels, preferred speech interference level, perceived noise level, and limiting times for total daily exposure of personnel with and without standard Air Force ear protectors.
NASA Astrophysics Data System (ADS)
Hyppolito, Thais; Angiboust, Samuel; Juliani, Caetano; Glodny, Johannes; Garcia-Casco, Antonio; Calderon, Mauricio; Chopin, Christian
2016-04-01
The remote Diego de Almagro Island, Chile (51° 30' S) exposes one of the rare vestiges of the Cretaceous paleo-subduction system of western South America. It is constituted by two main tectonic units formed by mafic rocks and metasediments: the high temperature/middle pressure Lázaro unit to the East and the high pressure-low temperature Almagro Complex to the West. We herein focus on the Almagro Complex, a pluri-kilometer thick subducted sequence comprising dominantly metatuffs, but also Grt-micaschists, meta-pillow lavas (showing MORB and OIB signatures) and metacherts (transformed to quartz+garnet-rich layers). Despite its apparent homogeneity, the Almagro Complex is actually composed of two distinct units (Willner et al., 2004) with distinct pressure-temperature-time paths. The Garnet Amphibolite unit (GA) shows three chemically and microstructurally distinct garnet generations that grew and (re)-equilibrated between 1.1 GPa and 1.7 GPa (35-55 km) and between 500°C and 600°C. We report for the first time in Chilean Patagonia the presence of rare relicts of omphacite in equilibrium with garnet in mafic layers together with the finding of chloritoid inclusions in garnet from metasediments, and omphacite and glaucophane inclusions in metatuffs. Our P-T estimates, based on pseudosection modeling, single/multi-equilibrium estimates and Raman spectroscopy of organic matter, demonstrate that rocks from the GA unit reached eclogite facies at around 1.7 to 1.8 GPa. Rb-Sr mineral data for Grt-amphibolites indicates that the amphibolitization overprint - which varies in intensity throughout the GA unit - took place at c. 120 Ma. The Blueschist unit, structurally below the GA unit, comprises lithologies similar to the GA unit but finer grained than the former. On other hand, the Blueschist unit (i) does not show garnet with multiple overgrowths and omphacite crystals as seen in the in GA unit; (ii) exhibits slightly lower peak metamorphic conditions than the GA unit (c. 500 °C, 1.4 GPa); (iii) has not suffered the strong amphibolitization visible in the GA unit, and (iv) records blueschist facies deformation at ~80 Ma (Rb-Sr mineral data). Importantly, this cool 80 Ma old event heterogeneously overprinted the GA rocks as shown by silica-rich (Si = 3.5 pfu) rims around phengite (Si = 3.33 pfu) crystals and glaucophane overgrowths around amphibolite-facies hornblende. The amphibolitization stage recorded by GA unit reveals the presence of a transient warming up of the subduction thermal gradient from 9 °C/ km to c. 14 °C/km at c. 120 Ma. We propose that the GA unit has been subsequently cooled down at around 80 Ma coevally with peak metamorphism in the blueschist unit. Dissolution-overgrowth patterns visible in GA unit garnets may be viewed as the record of short-lived thermal pulses associated with discrete basal accretion events. Lately, GA and blueschist units have been tectonically juxtaposed near the root of the accretionary wedge (at c. 30 km depth) and exhumed coherently. Our P-T-t reconstructions for Diego de Almagro rocks bear implications for reconstructing the physical nature of the subduction interface as well as for the understanding of transient, deep accretionary processes taking place near the roots of the seismogenic zone.
Skougstad, M.W.; Scarbro, G.F.
1968-01-01
A readily portable, all plastic, pressure filtration unit is described which greatly facilitates rapid micropore membrane field filtration of up to several liters of water with a minimum risk of inorganic chemical alteration or contamination of the sample. The unit accommodates standard 10.2-cm. (4-inch) diameter filters. The storage and carrying case serves as a convenient filter stand for both field and laboratory use.
Bubble performance of a novel dissolved air flotation(DAF) unit.
Chen, Fu-tai; Peng, Feng-xian; Wu, Xiao-qing; Luan, Zhao-kun
2004-01-01
ES-DAF, a novel DAF with low cost, high reliability and easy controllability, was studied. Without a costly air saturator, ES-DAF consists of an ejector and a static mixer between the pressure side and suction side of the recycle rotary pump. The bubble size distribution in this novel unit was studied in detail by using a newly developed CCD imagination through a microscope. Compared with M-DAF under the same saturation pressure, ES-DAF can produce smaller bubble size and higher bubble volume concentration, especially in lower pressure. In addition, the bubble size decreases with the increase of reflux ratio or decrease of superficial air-water ratio. These results suggested that smaller bubbles will be formed when the initial number of nucleation sites increases by enhancing the turbulence intensity in the saturation system.
Vertical array measurements of humpback whale songs
NASA Astrophysics Data System (ADS)
Au, Whitlow W. L.; Lammers, Marc O.; Pack, Adam A.; Herman, Louis
2004-05-01
The songs of eight male humpback whales were recorded at ranges varying from 20 to 40 m with a vertical array of hydrophones that had a flat frequency response to 24 kHz. The songs consisted of bursts of sounds called units. Units were organized into phrases and phrases into themes. Most of the units had mean duration between 1 and 2 s and mean silent periods between units between 1 and 2 s. Many of the recorded songs contained units that had high-frequency harmonics that extended beyond 22 kHz. These harmonic results suggest that humpback whale songs have a broadband quality not previously reported and may provide some insights on the high-frequency limit of hearing in these whales. The source levels of the songs were also estimated by considering the root-mean-square sound-pressure level referenced to 1 m for the unit with the largest level for different phrase within a song. Source levels varied between 171 to 189 dB re: 1 μPa. Singing escorts have been regularly observed within two whale lengths of females and these observations and knowledge of source levels provide estimates of sound-pressure levels that male humpback whales expose female whales to.
Predicting Envelope Leakage in Attached Dwellings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Faakye, O.; Arena, L.; Griffiths, D.
2013-07-01
The most common method for measuring air leakage is to use a single blower door to pressurize and/or depressurize the test unit. In detached housing, the test unit is the entire home and the single blower door measures air leakage to the outside. In attached housing, this 'single unit', 'total', or 'solo' test method measures both the air leakage between adjacent units through common surfaces as well air leakage to the outside. Measuring and minimizing this total leakage is recommended to avoid indoor air quality issues between units, reduce energy losses to the outside, reduce pressure differentials between units, andmore » control stack effect. However, two significant limitations of the total leakage measurement in attached housing are: for retrofit work, if total leakage is assumed to be all to the outside, the energy benefits of air sealing can be significantly over predicted; for new construction, the total leakage values may result in failing to meet an energy-based house tightness program criterion. The scope of this research is to investigate an approach for developing a viable simplified algorithm that can be used by contractors to assess energy efficiency program qualification and/or compliance based upon solo test results.« less
Liquid Hydrogen Regulated Low Pressure High Flow Pneumatic Panel AFT Arrow Analysis
NASA Technical Reports Server (NTRS)
Jones, Kelley, M.
2013-01-01
Project Definition: Design a high flow pneumatic regulation panel to be used with helium and hydrogen. The panel will have two circuits, one for gaseous helium (GHe) supplied from the GHe Movable Storage Units (MSUs) and one for gaseous hydrogen (GH2) supplied from an existing GH2 Fill Panel. The helium will supply three legs; to existing panels and on the higher pressure leg and Simulated Flight Tanks (SFTs) for the lower pressure legs. The hydrogen line will pressurize a 33,000 gallon vacuum jacketed vessel.
17. Governor Accumulator Tank Compressor and motor located along rear ...
17. Governor Accumulator Tank Compressor and motor located along rear corridor between Units 3 and 4, view to the west. The compressor motor is located just right of center in photograph. The pressure tank on the right side of the photograph is a reserve pressure tank for governor system. The pressure tank on the left side of the photograph is the original instrument air pressure tank. - Washington Water Power Clark Fork River Noxon Rapids Hydroelectric Development, Powerhouse, South bank of Clark Fork River at Noxon Rapids, Noxon, Sanders County, MT
Code of Federal Regulations, 2012 CFR
2012-07-01
... access lid or hatch), or automatically operated (e.g., a spring-loaded pressure relief valve). Hard... includes hard-piping, all drains and junction boxes, together with their associated sewer lines and other... management units include containers, air flotation units, oil-water separators or organic-water separators...
Code of Federal Regulations, 2014 CFR
2014-07-01
... access lid or hatch), or automatically operated (e.g., a spring-loaded pressure relief valve). Hard... includes hard-piping, all drains and junction boxes, together with their associated sewer lines and other... management units include containers, air flotation units, oil-water separators or organic-water separators...
Code of Federal Regulations, 2013 CFR
2013-07-01
... access lid or hatch), or automatically operated (e.g., a spring-loaded pressure relief valve). Hard... includes hard-piping, all drains and junction boxes, together with their associated sewer lines and other... management units include containers, air flotation units, oil-water separators or organic-water separators...
NASA Technical Reports Server (NTRS)
Cui, J.; Wilson, T. E.; Shibasaki, M.; Hodges, N. A.; Crandall, C. G.
2001-01-01
To identify whether muscle metaboreceptor stimulation alters baroreflex control of muscle sympathetic nerve activity (MSNA), MSNA, beat-by-beat arterial blood pressure (Finapres), and electrocardiogram were recorded in 11 healthy subjects in the supine position. Subjects performed 2 min of isometric handgrip exercise at 40% of maximal voluntary contraction followed by 2.5 min of posthandgrip muscle ischemia. During muscle ischemia, blood pressure was lowered and then raised by intravenous bolus infusions of sodium nitroprusside and phenylephrine HCl, respectively. The slope of the relationship between MSNA and diastolic blood pressure was more negative (P < 0.001) during posthandgrip muscle ischemia (-201.9 +/- 20.4 units. beat(-1). mmHg(-1)) when compared with control conditions (-142.7 +/- 17.3 units. beat(-1). mmHg(-1)). No significant change in the slope of the relationship between heart rate and systolic blood pressure was observed. However, both curves shifted during postexercise ischemia to accommodate the elevation in blood pressure and MSNA that occurs with this condition. These data suggest that the sensitivity of baroreflex modulation of MSNA is elevated by muscle metaboreceptor stimulation, whereas the sensitivity of baroreflex of modulate heart rate is unchanged during posthandgrip muscle ischemia.
Ventilation practices in the neonatal intensive care unit: a cross-sectional study.
van Kaam, Anton H; Rimensberger, Peter C; Borensztajn, Dorine; De Jaegere, Anne P
2010-11-01
To assess current ventilation practices in newborn infants. We conducted a 2-point cross-sectional study in 173 European neonatal intensive care units, including 535 infants (mean gestational age 28 weeks and birth weight 1024 g). Patient characteristics, ventilator settings, and measurements were collected bedside from endotracheally ventilated infants. A total of 457 (85%) patients were conventionally ventilated. Time cycled pressure-limited ventilation was used in 59% of these patients, most often combined with synchronized intermittent mandatory ventilation (51%). Newer conventional ventilation modes like volume targeted and pressure support ventilation were used in, respectively, 9% and 7% of the patients. The mean tidal volume, measured in 84% of the conventionally ventilated patients, was 5.7 ± 2.3 ml/kg. The mean positive end-expiratory pressure was 4.5 ± 1.1 cmH(2)O and rarely exceeded 7 cmH(2)O. Time cycled pressure-limited ventilation is the most commonly used mode in neonatal ventilation. Tidal volumes are usually targeted between 4 to 7 mL/kg and positive end-expiratory pressure between 4 to 6 cmH(2)O. Newer ventilation modes are only used in a minority of patients. Copyright © 2010 Mosby, Inc. All rights reserved.
Olefin unit primary fractionator on-line Petro-Blast Lancing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adams, W.D.; Rutan, C.R.
1994-12-31
Today`s commodity chemicals market forces companies to find innovative ways to extend unit on line operation between turnarounds such that they will remain economically competitive. At the OxyChem Chocolate Bayou facility the Primary Fractionator, quench oil column, fouling defined the length of the run between Olefin Unit turnarounds. Polymer growth on the valve trays restricted vapor flow through the column. This increased the column pressure drop which resulted in severe flooding. The inability to cool the furnace effluent while separating the fuel oil and gasoline components would cause premature shutdowns. Fouling locations were defined using gamma scan techniques and pressuremore » surveys. Nozzles were welded and hot tapped at strategic locations around the column. A high pressure Petro-Blast Lancing technique, inserted through the nozzles, was then used to clean the trays. The operation has extended the unit run length although the column may require additional Petro-Blast Lancing before the next scheduled plant turnaround. If this schedule holds, a two year extension in the unit run length will be realized.« less
Survey of Tsunamis Formed by Atmospheric Forcing on the East Coast of the United States
NASA Astrophysics Data System (ADS)
Lodise, J.; Shen, Y.; Wertman, C. A.
2014-12-01
High-frequency sea level oscillations along the United States East Coast have been linked to atmospheric pressure disturbances observed during large storm events. These oscillations have periods similar to tsunami events generated by earthquakes and submarine landslides, but are created by moving surface pressure anomalies within storm systems such as mesoscale convective systems or mid-latitude cyclones. Meteotsunamis form as in-situ waves, directly underneath a moving surface pressure anomaly. As the pressure disturbances move off the east coast of North America and over the continental shelf in the Atlantic Ocean, Proudman resonance, which is known to enhance the amplitude of the meteotsunami, may occur when the propagation speed of the pressure disturbance is equal to that of the shallow water wave speed. At the continental shelf break, some of the meteotsunami waves are reflected back towards the coast. The events we studied date from 2007 to 2014, most of which were identified using an atmospheric pressure anomaly detection method applied to atmospheric data from two National Data Buoy Center stations: Cape May, New Jersey and Newport, Rhode Island. The coastal tidal records used to observe the meteotsunami amplitudes include Montauk, New York; Atlantic City, New Jersey; and Duck, North Carolina. On average, meteotsunamis ranging from 0.1m to 1m in amplitude occurred roughly twice per month, with meteotsunamis larger than 0.4m occurring approximately 4 times per year, a rate much higher than previously reported. For each event, the amplitude of the recorded pressure disturbance was compared to the meteotsunami amplitude, while radar and bathymetry data were analyzed to observe the influence of Proudman resonance on the reflected meteotsunami waves. In-situ meteotsunami amplitudes showed a direct correlation with the amplitude of pressure disturbances. Meteotsunamis reflected off the continental shelf break were generally higher in amplitude when the average storm speed was closer to that of the shallow water wave speed, which suggests that Proudman resonance has a significant influence on meteotsunami amplitude over the continental shelf. Through the application of these findings the frequency and severity of future meteotsunamis can be better predicted along the east coast of the United States.
A light hydrocarbon fuel processor producing high-purity hydrogen
NASA Astrophysics Data System (ADS)
Löffler, Daniel G.; Taylor, Kyle; Mason, Dylan
This paper discusses the design process and presents performance data for a dual fuel (natural gas and LPG) fuel processor for PEM fuel cells delivering between 2 and 8 kW electric power in stationary applications. The fuel processor resulted from a series of design compromises made to address different design constraints. First, the product quality was selected; then, the unit operations needed to achieve that product quality were chosen from the pool of available technologies. Next, the specific equipment needed for each unit operation was selected. Finally, the unit operations were thermally integrated to achieve high thermal efficiency. Early in the design process, it was decided that the fuel processor would deliver high-purity hydrogen. Hydrogen can be separated from other gases by pressure-driven processes based on either selective adsorption or permeation. The pressure requirement made steam reforming (SR) the preferred reforming technology because it does not require compression of combustion air; therefore, steam reforming is more efficient in a high-pressure fuel processor than alternative technologies like autothermal reforming (ATR) or partial oxidation (POX), where the combustion occurs at the pressure of the process stream. A low-temperature pre-reformer reactor is needed upstream of a steam reformer to suppress coke formation; yet, low temperatures facilitate the formation of metal sulfides that deactivate the catalyst. For this reason, a desulfurization unit is needed upstream of the pre-reformer. Hydrogen separation was implemented using a palladium alloy membrane. Packed beds were chosen for the pre-reformer and reformer reactors primarily because of their low cost, relatively simple operation and low maintenance. Commercial, off-the-shelf balance of plant (BOP) components (pumps, valves, and heat exchangers) were used to integrate the unit operations. The fuel processor delivers up to 100 slm hydrogen >99.9% pure with <1 ppm CO, <3 ppm CO 2. The thermal efficiency is better than 67% operating at full load. This fuel processor has been integrated with a 5-kW fuel cell producing electricity and hot water.
Code of Federal Regulations, 2012 CFR
2012-01-01
... emergency operation. (d) The burner system (including the burner unit, controls, fuel lines, fuel cells...) Five hours at the maximum fuel pressure for which approval is sought, with a burn time for each one... intermediate fuel pressure, with a burn time for each one minute cycle of three to ten seconds. An intermediate...
Code of Federal Regulations, 2013 CFR
2013-01-01
... emergency operation. (d) The burner system (including the burner unit, controls, fuel lines, fuel cells...) Five hours at the maximum fuel pressure for which approval is sought, with a burn time for each one... intermediate fuel pressure, with a burn time for each one minute cycle of three to ten seconds. An intermediate...
Code of Federal Regulations, 2010 CFR
2010-01-01
... emergency operation. (d) The burner system (including the burner unit, controls, fuel lines, fuel cells...) Five hours at the maximum fuel pressure for which approval is sought, with a burn time for each one... intermediate fuel pressure, with a burn time for each one minute cycle of three to ten seconds. An intermediate...
Code of Federal Regulations, 2011 CFR
2011-01-01
... emergency operation. (d) The burner system (including the burner unit, controls, fuel lines, fuel cells...) Five hours at the maximum fuel pressure for which approval is sought, with a burn time for each one... intermediate fuel pressure, with a burn time for each one minute cycle of three to ten seconds. An intermediate...
Code of Federal Regulations, 2014 CFR
2014-01-01
... emergency operation. (d) The burner system (including the burner unit, controls, fuel lines, fuel cells...) Five hours at the maximum fuel pressure for which approval is sought, with a burn time for each one... intermediate fuel pressure, with a burn time for each one minute cycle of three to ten seconds. An intermediate...
ERIC Educational Resources Information Center
McClain, William C.
2013-01-01
Teachers in any school community must confront immense contextual pressures: developing parent and community relationships, implementing curriculum and content, preparing students for state assessment examinations, along with navigating the professional relationships that exist within the school community. These pressures are amplified in the case…
A Simple Boyle's Law Experiment.
ERIC Educational Resources Information Center
Lewis, Don L.
1997-01-01
Describes an experiment to demonstrate Boyle's law that provides pressure measurements in a familiar unit (psi) and makes no assumptions concerning atmospheric pressure. Items needed include bathroom scales and a 60-ml syringe, castor oil, disposable 3-ml syringe and needle, modeling clay, pliers, and a wooden block. Commercial devices use a…
USDA-ARS?s Scientific Manuscript database
Cardiovascular disease (CVD) is a major health risk in the United States. Major indicators of CVD risk include obesity, blood lipids, and blood pressure. Modifiable risk factors associated with CVD include body composition (body mass index and waist circumference), serum lipids, and blood pressure. ...
Machado, Juliana Pereira; Veiga, Eugenia Velludo; Ferreira, Paulo Alexandre Camargo; Martins, José Carlos Amado; Daniel, Ana Carolina Queiroz Godoy; Oliveira, Amanda dos Santos; da Silva, Patrícia Costa dos Santos
2014-01-01
Objective To determine and to analyze the theoretical and practical knowledge of Nursing professionals on indirect blood pressure measurement. Methods This cross-sectional study included 31 professionals of a coronary care unit (86% of the Nursing staff in the unit). Of these, 38.7% of professionals were nurses and 61.3% nurse technicians. A validated questionnaire was used to theoretical evaluation and for practice assessment the auscultatory technique was applied in a simulation environment, under a non-participant observation. Results To the theoretical knowledge of the stages of preparation of patient and environment, 12.9% mentioned 5-minute of rest, 48.4% checked calibration, and 29.0% chose adequate cuff width. A total of 64.5% of professionals avoided rounding values, and 22.6% mentioned the 6-month deadline period for the equipment calibration. On average, in practice assessment, 65% of the steps were followed. Lacks in knowledge were primary concerning lack of checking the device calibration and stethoscope, measurement of arm circumference to choose the cuff size, and the record of arm used in blood pressure measurement. Conclusion Knowledge was poor and had disparities between theory and practice with evidence of steps taken without proper awareness and lack of consideration of important knowledge during implementation of blood pressure measurement. Educational and operational interventions should be applied systematically with institutional involvement to ensure safe care with reliable values. PMID:25295455
NASA Technical Reports Server (NTRS)
Ray, C. A.
2001-01-01
Evidence from animals indicates that skeletal muscle afferents activate the vestibular nuclei and that both vestibular and skeletal muscle afferents have inputs to the ventrolateral medulla. The purpose of the present study was to investigate the interaction between the vestibulosympathetic and skeletal muscle reflexes on muscle sympathetic nerve activity (MSNA) and arterial pressure in humans. MSNA, arterial pressure, and heart rate were measured in 17 healthy subjects in the prone position during three experimental trials. The three trials were 2 min of 1) head-down rotation (HDR) to engage the vestibulosympathetic reflex, 2) isometric handgrip (IHG) at 30% maximal voluntary contraction to activate skeletal muscle afferents, and 3) HDR and IHG performed simultaneously. The order of the three trials was randomized. HDR and IHG performed alone increased total MSNA by 46 +/- 16 and 77 +/- 24 units, respectively (P < 0.01). During the HDR plus IHG trial, MSNA increased 142 +/- 38 units (P < 0.01). This increase was not significantly different from the sum of the individual trials (130 +/- 41 units). This finding was also observed with mean arterial pressure (sum = 21 +/- 2 mmHg and HDR + IHG = 22 +/- 2 mmHg). These findings suggest that there is an additive interaction for MSNA and arterial pressure when the vestibulosympathetic and skeletal muscle reflexes are engaged simultaneously in humans. Therefore, no central modulation exists between these two reflexes with regard to MSNA output in humans.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rempe, Joy L.; Knudson, Darrell L.
2015-02-01
The accidents at the Three Mile Island Unit 2 (TMI-2) Pressurized Water Reactor (PWR) and the Daiichi Units 1, 2, and 3 Boiling Water Reactors (BWRs) provide unique opportunities to evaluate instrumentation exposed to severe accident conditions. Conditions associated with the release of coolant and the hydrogen burn that occurred during the TMI-2 accident exposed instrumentation to harsh conditions, including direct radiation, radioactive contamination, and high humidity with elevated temperatures and pressures. Post-TMI-2 instrumentation evaluation programs focused on data required by TMI-2 operators to assess the condition of the reactor and containment and the effect of mitigating actions taken bymore » these operators. Prior efforts also focused on sensors providing data required for subsequent forensic evaluations and accident simulations. This paper provides additional details related to the formal process used to develop a qualified TMI-2 data base and presents data qualification details for three parameters: reactor coolant system (RCS) pressure; containment building temperature; and containment pressure. These selected examples illustrate the types of activities completed in the TMI-2 data qualification process and the importance of such a qualification effort. These details are described to facilitate implementation of a similar process using data and examinations at the Daiichi Units 1, 2, and 3 reactors so that BWR-specific benefits can be obtained.« less
Arqués, J L; Garde, S; Gaya, P; Medina, M; Nuñez, M
2006-03-01
La Serena cheese, a Spanish variety made from Merino ewes' raw milk, has a high pH value, low salt content, and high moisture, conditions that are all favorable for growth and survival of contaminating microorganisms, including pathogens. To improve its microbiological quality and safety, high-pressure treatments at 300 or 400 MPa for 10 min at 10 degrees C were applied to 2 batches of La Serena cheese on d 2 or 50 of ripening. Cheese treated on d 2 at 300 MPa showed viable aerobic counts that were 0.99 log units lower than those for control cheese on d 3 and showed counts of enterococci, coagulase-positive staphylococci, gram-negative bacteria, and coliforms that were 2.05, 0.49, 3.14, and 4.13 log units lower, respectively, than control cheese. For cheese treated on d 2 at 400 MPa, the respective reductions in counts were 2.02, 2.68, 1.45, 3.96, and 5.50 log units. On d 60, viable aerobic counts in cheese treated on d 50 at 300 MPa were 0.50 log units lower than those in control cheese, and counts of enterococci, gram-negative bacteria, and coliforms were 1.37, 2.30, and 4.85 log units lower, respectively. For cheese treated on d 50 at 400 MPa, the respective reductions in counts were 1.29, 1.98, 4.47, and > 5 log units. High-pressure treatments at 300 or 400 MPa on d 2 or 50 reduced significantly the counts of undesirable microorganisms, improving the microbiological quality and safety of La Serena cheese immediately after treatment and at the end of the ripening period.
Diminished forearm vasomotor response to central hypervolemic loading in aerobically fit individuals
NASA Technical Reports Server (NTRS)
Shi, X.; Gallagher, K. M.; SMith, S. A.; Bryant, K. H.; Raven, P. B.; Blomqvist, C. G. (Principal Investigator)
1996-01-01
The aim of this study was to test the hypothesis that cardiopulmonary baroreflex control of forearm vascular resistance (FVR) during central hypervolemic loading was less sensitive in exercise trained high fit individuals (HF) compared to untrained average fit individuals (AF). Eight AF (age: 24 +/- 1 yr and weight: 78.9 +/- 1.7 kg) and eight HF (22 +/- 1 yr 79.5 +/- 2.4 kg) voluntarily participated in the investigation. Maximal aerobic power (determined on a treadmill), plasma volume and blood volume (Evans blue dilution method) were significantly greater in the HF than AF (60.8 +/- 0.7 vs. 41.2 +/- 1.9 ml.kg-1.min-1, 3.96 +/- 0.17 vs 3.36 +/- 0.08 1, and 6.33 +/- 0.23 vs 5.28 +/- 0.13 1). Baseline heart rate (HR), central venous pressure (CVP), mean arterial pressure (MAP, measured by an intraradial catheter or a Finapres finger cuff), forearm blood flow (FBF, plethysmography), and FVR, calculated from the ratio (MAP-CVP)/FBF, were not different between the HF and the AF. Lower body negative pressure (LBNP, -5, -10, -15, and -20 torr) and passive leg elevation (LE, 50 cm) combined with lower body positive pressure (LBPP, +5, +10, and +20 torr) were utilized to elicit central hypovolemia and hypervolemia, respectively. Range of CVP (from LBNP to LE+LBPP) was similar in the AF (from -3.9 to +1.9 mm Hg) and HF (from -4.0 to +2.2 mm Hg). However, FVR/CVP was significantly less in the HF (-1.8 +/- 0.1 unit.mm Hg-1) than AF (-34 +/- 0.1 unit.mm Hg-1). The FVR decrease in response to increase in CVP was significantly diminished in the HF (-1.46 +/- 0.45 unit.mm Hg-1) compared to the AF (-4.40 +/- 0.97 unit.mm Hg-1), and during LBNP induced unloading the FVR/CVP of the HF (-2.01 +/- 0.49 unit.mm Hg-1) was less (P < 0.08) than the AF (-3.28 +/- 0.69 unit.mm Hg-1). We concluded that the cardiopulmonary baroreceptor mediated FVR reflex response was significantly less sensitive to changes in CVP in individuals who practice exercise training.
2015-10-30
pressure values onto the SD card. The addition of free and open-source Arduino libraries allowed for the seamless integration of the shield into the...alert the user when replacing the separator is necessary. Methods: A sensor was built to measure and record differential pressure values within the...from the transducers during simulated blockages were transformed into pressure values using linear regression equations from the calibration data
High-pressure portable pneumatic drive unit.
Hete, B F; Savage, M; Batur, C; Smith, W A; Golding, L A; Nosé, Y
1989-12-01
The left ventricular assist device (LVAD) of the Cleveland Clinic Foundation (CCF) is a single-chamber assist pump, driven by a high-pressure pneumatic cylinder. A low-cost, portable driver that will allow cardiac care patients, with a high-pressure pneumatic ventricle assist, more freedom of movement has been developed. The compact and light-weight configuration can provide periods of 2 h of freedom from a fixed position driver and does not use exotic technology.
Large-Scale Physical Models of Thermal Remediation of DNAPL Source Zones in Aquitards
2009-05-01
pressure at the bottom of the tank. The higher pressure is reflected in higher measured water levels in external gauges . Figure 63: 3D Cross...than atmospheric. This higher pressure can raise the apparent water level in a sight gauge or external overflow and can even drive more fluid through...the water table. All met or exceeded their goals. Typical turnkey unit costs (including design, permitting, fabrication, mobilization, drilling
Hospital Magnet Status, Unit Work Environment, and Pressure Ulcers.
Ma, Chenjuan; Park, Shin Hye
2015-11-01
To identify how organizational nursing factors at different structural levels (i.e., unit-level work environment and hospital Magnet status) are associated with hospital-acquired pressure ulcers (HAPUs) in U.S. acute care hospitals. A cross-sectional observational study used data from the National Database of Nursing Quality Indicators®. Responses from 33,845 registered nurses (RNs) were used to measure unit work environments. The unit of analysis was the nursing unit, and there were 1,381 units in 373 hospitals in the United States. Unit work environment was measured by the Practice Environment Scale of Nurse Working Index (PES-NWI). Multilevel logistic regressions were used to estimate the effects of unit work environment and hospital Magnet status on HAPUs. All models were controlled for hospital and unit characteristics when considering clustering of units within hospitals. Magnet hospital units had 21% lower odds of having an HAPU than non-Magnet hospital units (95% confidence interval [CI], 0.64-0.98). With one unit increase of the PES-NWI score, units had 29% lower odds of having an HAPU (95% CI, 0.55-0.91). When including both hospital Magnet status and unit work environment in the model, hospital Magnet status no longer had a significant effect on HAPUs (odds ratio [OR] = 0.82; 95% CI, 0.66-1.02), whereas the significant effect of unit work environment persisted (OR = 0.73; 95% CI, 0.56-0.93). Both hospital and unit environments were significantly associated with HAPUs, and the unit-level work environment can be more influential in reducing HAPUs. Investment in the nurse work environments at both the hospital level and unit level has the potential to reduce HAPUs; and additional to hospital-level initiatives (e.g., Magnet recognition program), efforts targeting on-unit work environments deserve more attention. © 2015 Sigma Theta Tau International.
Research pressure instrumentation for NASA space shuttle main engine
NASA Technical Reports Server (NTRS)
Anderson, P. J.; Nussbaum, P.; Gustafson, G.
1985-01-01
The breadboard feasibility model of a silicon piezoresistive pressure transducer suitable for space shuttle main engine (SSME) applications was demonstrated. The development of pressure instrumentation for the SSME was examined. The objective is to develop prototype pressure transducers which are targeted to meet the SSME performance design goals and to fabricate, test and deliver a total of 10 prototype units. Effective utilization of the many advantages of silicon piezoresistive strain sensing technology to achieve the objectives of advanced state-of-the-art pressure sensors for reliability, accuracy and ease of manufacture is analyzed. Integration of multiple functions on a single chip is the key attribute of the technology.
The Pressure-Induced Polymorphic Transformations in Fluconazole.
Gorkovenko, Ekaterina A; Kichanov, Sergey E; Kozlenko, Denis P; Belushkin, Alexandr V; Wąsicki, Jan; Nawrocik, Wojciech; Mielcarek, Jadwiga; Dubrovinsky, Leonid S; Lathe, Christian; Savenko, Boris N
2015-12-01
The structural properties and Raman spectra of fluconazole have been studied by means of X-ray diffraction and Raman spectroscopy at pressures up to 2.5 and 5.5 GPa, respectively. At a pressure of 0.8 GPa, a polymorphic phase transition from the initial form I to a new triclinic form VIII has been observed. At higher pressure of P = 3.2 GPa, possible transformation into another new polymorphic form IX has been detected. The unit cell parameters and volumes, and vibration modes as functions of pressure have been obtained for the different forms of fluconazole. © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association.
Zhao, Jing; Ross, Nancy L; Wang, Di; Angel, Ross J
2011-11-16
The structural evolution of orthorhombic CaTiO3 perovskite has been studied using high-pressure single-crystal x-ray diffraction under hydrostatic conditions up to 8.1 GPa and under a non-hydrostatic stress field formed in a diamond anvil cell (DAC) up to 4.7 GPa. Under hydrostatic conditions, the TiO6 octahedra become more tilted and distorted with increasing pressure, similar to other 2:4 perovskites. Under non-hydrostatic conditions, the experiments do not show any apparent difference in the internal structural variation from hydrostatic conditions and no additional tilts and distortions in the TiO6 octahedra are observed, even though the lattice itself becomes distorted due to the non-hydrostatic stress. The similarity between the hydrostatic and non-hydrostatic cases can be ascribed to the fact that CaTiO3 perovskite is nearly elastically isotropic and, as a consequence, its deviatoric unit-cell volume strain produced by the non-hydrostatic stress is very small; in other words, the additional octahedral tilts relevant to the extra unit-cell volume associated with the deviatoric unit-cell volume strain may be totally neglected. This study further addresses the role that three factors--the elastic properties, the crystal orientation and the pressure medium--have on the structural evolution of an orthorhombic perovskite loaded in a DAC under non-hydrostatic conditions. The influence of these factors can be clearly visualized by plotting the three-dimensional distribution of the deviatoric unit-cell volume strain in relation to the cylindrical axis of the DAC and indicates that, if the elasticity of a perovskite is nearly isotropic as it is for CaTiO3, the other two factors become relatively insignificant.
Subjective time pressure: general or domain specific?
Kleiner, Sibyl
2014-09-01
Chronic time pressure has been identified as a pervasive societal problem, exacerbated by high demands of the labor market and the home. Yet time pressure has not been disaggregated and examined separately across home and work contexts, leaving many unanswered questions regarding the sources and potentially stressful consequences of time pressure. Using data collected in the United States General Social Survey waves 2002 and 2004, this study disaggregates time pressure into the domains of home and work, and asks whether considering time pressures within distinct work and home contexts reveals distinct predictors or associations with stress. Findings show that both predictors and stress associations differ across work and home pressures, revealing both methodological and theoretical implications for the study of time pressure and work and family life more generally. Copyright © 2014 Elsevier Inc. All rights reserved.
Integrating Out-Of-Office Blood Pressure in the Diagnosis and Management of Hypertension
Cohen, Jordana B.; Cohen, Debbie L.
2016-01-01
Guidelines for the diagnosis and monitoring of hypertension were historically based on in-office blood pressure measurements. However, the United States Preventive Services Task Force recently expanded their recommendations on screening for hypertension to include out-of-office blood pressure measurements to confirm the diagnosis of hypertension. Out-of-office blood pressure monitoring, including ambulatory blood pressure monitoring and home blood pressure monitoring, are important tools in distinguishing between normotension, masked hypertension, white-coat hypertension, and sustained (including uncontrolled or drug-resistant) hypertension. Compared to in-office readings, out-of-office blood pressures are a greater predictor of renal and cardiac morbidity and mortality. There are multiple barriers to the implementation of out-of-office blood pressure monitoring which need to be overcome in order to promote more widespread use of these modalities. PMID:27677895
Pressure balance cross-calibration method using a pressure transducer as transfer standard
Olson, D; Driver, R. G.; Yang, Y
2016-01-01
Piston gauges or pressure balances are widely used to realize the SI unit of pressure, the pascal, and to calibrate pressure sensing devices. However, their calibration is time consuming and requires a lot of technical expertise. In this paper, we propose an alternate method of performing a piston gauge cross calibration that incorporates a pressure transducer as an immediate in-situ transfer standard. For a sufficiently linear transducer, the requirement to exactly balance the weights on the two pressure gauges under consideration is greatly relaxed. Our results indicate that this method can be employed without a significant increase in measurement uncertainty. Indeed, in the test case explored here, our results agreed with the traditional method within standard uncertainty, which was less than 6 parts per million. PMID:28303167
Water balance in irrigation districts. Uncertainty in on-demand pressurized networks
NASA Astrophysics Data System (ADS)
Sánchez-Calvo, Raúl; Rodríguez-Sinobas, Leonor; Juana, Luis; Laguna, Francisco Vicente
2015-04-01
In on-demand pressurized irrigation distribution networks, applied water volume is usually controlled opening a valve during a calculated time interval, and assuming constant flow rate. In general, pressure regulating devices for controlling the discharged flow rate by irrigation units are needed due to the variability of pressure conditions. A pressure regulating valve PRV is the commonly used pressure regulating device in a hydrant, which, also, executes the open and close function. A hydrant feeds several irrigation units, requiring a wide range in flow rate. In addition, some flow meters are also available, one as a component of the hydrant and the rest are placed downstream. Every land owner has one flow meter for each group of field plots downstream the hydrant. Ideal PRV performance would maintain a constant downstream pressure. However, the true performance depends on both upstream pressure and the discharged flow rate. Theoretical flow rates values have been introduced into a PRV behavioral model, validated in laboratory, coupled with an on-demand irrigation district waterworks, composed by a distribution network and a multi-pump station. Variations on flow rate are simulated by taking into account the consequences of variations on climate conditions and also decisions in irrigation operation, such us duration and frequency application. The model comprises continuity, dynamic and energy equations of the components of both the PRV and the water distribution network. In this work the estimation of water balance terms during the irrigation events in an irrigation campaign has been simulated. The effect of demand concentration peaks has been estimated.
NASA Astrophysics Data System (ADS)
O'Bannon, E. F., III; Vennari, C.; Beavers, C. C. G.; Williams, Q. C.
2015-12-01
Lawsonite (CaAl2Si2O7(OH)2.H2O) is a hydrous mineral with a high overall water content of ~11.5 wt.%. It is a significant carrier of water in subduction zones to depths greater than ~150 km. The structure of lawsonite has been extensively studied under room temperature, high-pressure conditions. However, simultaneous high-pressure and high-temperature experiments are scarce. We have conducted synchrotron-based simultaneous high-pressure and temperature single crystal experiments on lawsonite up to a maximum pressure of 8.4 GPa at ambient and high temperatures. We used a natural sample of lawsonite from Valley Ford, California (Sonoma County). At room pressure and temperature lawsonite crystallizes in the orthorhombic system with Cmcm symmetry. Room temperature compression indicates that lawsonite remains in the orthorhombic Cmcm space group up to ~9.0 GPa. Our 5.0 GPa crystal structure is similar to the room pressure structure, and shows almost isotropic compression of the crystallographic axes. Unit cell parameters at 5.0 GPa are a- 5.7835(10), b- 8.694(2), and c- 13.009(3). Single-crystal measurements at simultaneous high-pressure and temperature (e.g., >8.0 GPa and ~100 oC) can be indexed to a monoclinic P-centered unit cell. Interestingly, a modest temperature increase of ~100 oC appears to initiate the orthorhombic to monoclinic phase transition at ~0.6-2.4 GPa lower than room temperature compression studies have shown. There is no evidence of dehydration or H atom disorder under these conditions. This suggests that the orthorhombic to monoclinic transition could be kinetically impeded at 298 K, and that monoclinic lawsonite could be the dominant water carrier through much of the depth range of upper mantle subduction processes.
NASA Astrophysics Data System (ADS)
Sweijen, Thomas; Aslannejad, Hamed; Hassanizadeh, S. Majid
2017-09-01
In studies of two-phase flow in complex porous media it is often desirable to have an estimation of the capillary pressure-saturation curve prior to measurements. Therefore, we compare in this research the capability of three pore-scale approaches in reproducing experimentally measured capillary pressure-saturation curves. To do so, we have generated 12 packings of spheres that are representative of four different glass-bead packings and eight different sand packings, for which we have found experimental data on the capillary pressure-saturation curve in the literature. In generating the packings, we matched the particle size distributions and porosity values of the granular materials. We have used three different pore-scale approaches for generating the capillary pressure-saturation curves of each packing: i) the Pore Unit Assembly (PUA) method in combination with the Mayer and Stowe-Princen (MS-P) approximation for estimating the entry pressures of pore throats, ii) the PUA method in combination with the hemisphere approximation, and iii) the Pore Morphology Method (PMM) in combination with the hemisphere approximation. The three approaches were also used to produce capillary pressure-saturation curves for the coating layer of paper, used in inkjet printing. Curves for such layers are extremely difficult to determine experimentally, due to their very small thickness and the presence of extremely small pores (less than one micrometer in size). Results indicate that the PMM and PUA-hemisphere method give similar capillary pressure-saturation curves, because both methods rely on a hemisphere to represent the air-water interface. The ability of the hemisphere approximation and the MS-P approximation to reproduce correct capillary pressure seems to depend on the type of particle size distribution, with the hemisphere approximation working well for narrowly distributed granular materials.
Exergy analysis of biomass organic Rankine cycle for power generation
NASA Astrophysics Data System (ADS)
Nur, T. B.; Sunoto
2018-02-01
The study examines proposed small biomass-fed Organic Rankine Cycle (ORC) power plant through exergy analysis. The system consists of combustion burner unit to utilize biomass as fuel, and organic Rankine cycle unit to produce power from the expander. The heat from combustion burner was transfered by thermal oil heater to evaporate ORC working fluid in the evaporator part. The effects of adding recuperator into exergy destruction were investigated. Furthermore, the results of the variations of system configurations with different operating parameters, such as the evaporating pressures, ambient temperatures, and expander pressures were analyzed. It was found that the largest exergy destruction occurs during processes are at combustion part, followed by evaporator, condenser, expander, and pump. The ORC system equipped with a recuperator unit exhibited good operational characteristics under wide range conditions compared to the one without recuperator.
Hydroelectric System Response to Part Load Vortex Rope Excitation
NASA Astrophysics Data System (ADS)
Alligné, S.; Nicolet, C.; Bégum, A.; Landry, C.; Gomes, J.; Avellan, F.
2016-11-01
The prediction of pressure and output power fluctuations amplitudes on Francis turbine prototype is a challenge for hydro-equipment industry since it is subjected to guarantees to ensure smooth and reliable operation of the hydro units. The European FP7 research project Hyperbole aims to setup a methodology to transpose the pressure fluctuations induced by the cavitation vortex rope on the reduced scale model to the prototype generating units. A Francis turbine unit of 444MW with a specific speed value of v = 0.29, is considered as case study. A SIMSEN model of the power station including electrical system, controllers, rotating train and hydraulic system with transposed draft tube excitation sources is setup. Based on this model, a frequency analysis of the hydroelectric system is performed to analyse potential interactions between hydraulic excitation sources and electrical components.
Saherwala, Ali A; Stutzman, Sonja E; Osman, Mohamed; Kalia, Junaid; Figueroa, Stephen A; Olson, DaiWai M; Aiyagari, Venkatesh
2018-03-22
The correlation between noninvasive (oscillometric) blood pressure (NBP) and intra-arterial blood pressure (IAP) in critically ill patients receiving vasoactive medications in a Neurocritical Care Unit has not been systematically studied. The purpose of this study is to examine the relationship between simultaneously measured NBP and IAP recordings in these patients. Prospective observational study of patients (N = 70) admitted to a neurocritical care unit receiving continuous vasopressor or antihypertensive infusions. Paired NBP/IAP observations along with covariate and demographic data were abstracted via chart audit. Analysis was performed using SAS v9.4. A total of 2177 paired NBP/IAP observations from 70 subjects (49% male, 63% white, mean age 59 years) receiving vasopressors (n = 21) or antihypertensive agents (n = 49) were collected. Paired t test analysis showed significant differences between NBP versus IAP readings: ([systolic blood pressure (SBP): mean = 136 vs. 140 mmHg; p < 0.0001], [diastolic blood pressure (DBP): mean = 70 vs. 68 mmHg, p < 0.0001], [mean arterial blood pressure (MAP): mean = 86 vs. 90 mmHg, p < 0.0001]). Bland-Altman plots for MAP, SBP, and DBP demonstrate good inter-method agreement between paired measures (excluding outliers) and demonstrate NBP-IAP SBP differences at extremes of blood pressures. Pearson correlation coefficients show strong positive correlations for paired MAP (r = 0.82), SBP (r = 0.84), and DBP (r = 0.73) recordings. An absolute NBP-IAP SBP difference of > 20 mmHg was seen in ~ 20% of observations of nicardipine, ~ 25% of observations of norepinephrine, and ~ 35% of observations of phenylephrine. For MAP, the corresponding numbers were ~ 10, 15, and 25% for nicardipine, norepinephrine, and phenylephrine, respectively. Despite overall strong positive correlations between paired NBP and IAP readings of MAP and SBP, clinically relevant differences in blood pressure are frequent. When treating with vasoactive infusions targeted to a specific BP goal, it is important to keep in mind that NBP and IAP values are not interchangeable.
76 FR 68661 - Airworthiness Directives; Turbomeca S.A. Arriel 2B and 2B1 Turboshaft Engines
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-07
... high- pressure (HP) pump shaft on HP/LP pump hydro-mechanical metering units (HMUs) that do not...-mechanical metering unit (HMU) LP fuel pump impeller and the HP fuel pump shaft, since AD 2010-03-06 (75 FR...
Research pressure instrumentation for NASA Space Shuttle main engine
NASA Technical Reports Server (NTRS)
Anderson, P. J.; Nussbaum, P.; Gustafson, G.
1984-01-01
The development of prototype pressure transducers which are targeted to meet the Space Shuttle Main Engine SSME performance design goals is discussed. The fabrication, testing and delivery of 10 prototype units is examined. Silicon piezoresistive strain sensing technology is used to achieve the objectives of advanced state-of-the-art pressure sensors in terms of reliability, accuracy and ease of manufacture. Integration of multiple functions on a single chip is the key attribute of this technology.
Tuning and synthesis of metallic nanostructures by mechanical compression
Fan, Hongyou; Li, Binsong
2015-11-17
The present invention provides a pressure-induced phase transformation process to engineer metal nanoparticle architectures and to fabricate new nanostructured materials. The reversible changes of the nanoparticle unit cell dimension under pressure allow precise control over interparticle separation in 2D or 3D nanoparticle assemblies, offering unique robustness for interrogation of both quantum and classic coupling interactions. Irreversible changes above a threshold pressure of about 8 GPa enables new nanostructures, such as nanorods, nanowires, or nanosheets.
Biaxial and Shear Testing Apparatus with Force Controls
2006-03-30
materials as the test specimen. (2) Description of the Prior Art [0004] It is known in the art that pressurized fabric tubes ; pressure-stabilized beams...apparatus is that these roller pins prevent any torsional load from reaching the test specimen. [0010] In Ward et al., (United States Patent No. 5,279,166...loading a specimen through pressurizing the inside surface of a cylinder is disclosed. A thin-wall tube specimen is biaxially tested for stress analysis
1990-06-15
on which three major points may be located: (1) The first point is where the military acting only as a pressure group with lobbying capability. (2...252) Considering the level of intervention, the pressure group seems to be a natural relation between the military and the government through a civilian...Politicization: induced. (d) Means of control: attempt to infiltrate the military. (e) Level of control: pressure group . (f) Motivation: personal (only a
Raman Spectrum of Pressure Compacted Fused Silica.
1981-01-21
Spectrum of Pressure Compacted Fused Silica" bj G. E. Walrafen Department of Chemistry Howard University Washington, D. C. 20059 and P. N. Krishnan...RESEA,CH Task No. NR-0)1-733 T ’echnical opset No. 2 / Raman Spectrum of Pressure Compacted Fustd Si I ica, by G. E./Walrafen P. N./Krishnan Howard ... University Department of Chemistry Washington, D. C. 20059 Reproduction in whole or in part is permitted for any purpose of the United States
A pressure and shear sensor system for stress measurement at lower limb residuum/socket interface.
Laszczak, P; McGrath, M; Tang, J; Gao, J; Jiang, L; Bader, D L; Moser, D; Zahedi, S
2016-07-01
A sensor system for measurement of pressure and shear at the lower limb residuum/socket interface is described. The system comprises of a flexible sensor unit and a data acquisition unit with wireless data transmission capability. Static and dynamic performance of the sensor system was characterised using a mechanical test machine. The static calibration results suggest that the developed sensor system presents high linearity (linearity error ≤ 3.8%) and resolution (0.9 kPa for pressure and 0.2 kPa for shear). Dynamic characterisation of the sensor system shows hysteresis error of approximately 15% for pressure and 8% for shear. Subsequently, a pilot amputee walking test was conducted. Three sensors were placed at the residuum/socket interface of a knee disarticulation amputee and simultaneous measurements were obtained during pilot amputee walking test. The pressure and shear peak values as well as their temporal profiles are presented and discussed. In particular, peak pressure and shear of approximately 58 kPa and 27 kPa, respectively, were recorded. Their temporal profiles also provide dynamic coupling information at this critical residuum/socket interface. These preliminary amputee test results suggest strong potential of the developed sensor system for exploitation as an assistive technology to facilitate socket design, socket fit and effective monitoring of lower limb residuum health. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Goyal, R.; Gandhi, B. K.; Cervantes, M. J.
2018-06-01
Increased penetration of solar and the wind impels the designers of the hydroelectric power generation unit to provide more flexibility in operation for the stability of the grid. The power generating unit includes turbine which needs to sustain sudden change in its operating conditions. Thus, the hydraulic turbine experiences more transients per day which result in chronic problems such as fatigue to the runner, instrument malfunctioning, vibrations, wear and tear etc. This paper describes experiments performed on a high model (1.5:1) Francis turbine for load acceptances from the minimum load. The experiments presented in the paper are the part of Francis-99 workshop which aims to determine the performance of numerical models in simulations of model Francis turbine under steady and transient operating conditions. The aim of the paper is to present the transient pressure variation in the vaneless space of a Francis turbine where high-frequency pulsations are normally expected. For this, two pressure sensors, VL1 and VL2, are mounted at the vaneless space, one near the beginning of the spiral casing and the other before the end of the spiral casing. Both are used to capture the unsteady pressure field developed in the space between guide vanes and runner inlet. The time-resolved pressure signals are analyzed and presented during the transient to observe the pressure variation and dominant frequencies of pulsations.
Pulmonary hypertension due to acute respiratory distress syndrome
Ñamendys-Silva, S.A.; Santos-Martínez, L.E.; Pulido, T.; Rivero-Sigarroa, E.; Baltazar-Torres, J.A.; Domínguez-Cherit, G.; Sandoval, J.
2014-01-01
Our aims were to describe the prevalence of pulmonary hypertension in patients with acute respiratory distress syndrome (ARDS), to characterize their hemodynamic cardiopulmonary profiles, and to correlate these parameters with outcome. All consecutive patients over 16 years of age who were in the intensive care unit with a diagnosis of ARDS and an in situ pulmonary artery catheter for hemodynamic monitoring were studied. Pulmonary hypertension was diagnosed when the mean pulmonary artery pressure was >25 mmHg at rest with a pulmonary artery occlusion pressure or left atrial pressure <15 mmHg. During the study period, 30 of 402 critically ill patients (7.46%) who were admitted to the ICU fulfilled the criteria for ARDS. Of the 30 patients with ARDS, 14 met the criteria for pulmonary hypertension, a prevalence of 46.6% (95% CI; 28-66%). The most common cause of ARDS was pneumonia (56.3%). The overall mortality was 36.6% and was similar in patients with and without pulmonary hypertension. Differences in patients' hemodynamic profiles were influenced by the presence of pulmonary hypertension. The levels of positive end-expiratory pressure and peak pressure were higher in patients with pulmonary hypertension, and the PaCO2 was higher in those who died. The level of airway pressure seemed to influence the onset of pulmonary hypertension. Survival was determined by the severity of organ failure at admission to the intensive care unit. PMID:25118626
NASA Astrophysics Data System (ADS)
Bo, Jiang; Hao, Weidong; Hu, Zhihong; Liu, Fuguo
2015-12-01
In order to solve the problem of over temperature tube-burst caused by oxide scale shedding and blocking tubes of high temperature reheater of a 200MW super high pressure power plant boiler, this paper expounds the mechanism of scale forming and shedding, and analyzes the probable causes of the tube-burst failure. The results show that the root cause of scale forming is that greater steam extraction flow after reforming of the second extraction leads to less steam flow into reheater, which causes over temperature to some of the heated tubes; and the root cause of scale shedding is that long term operation in AGC-R mode brings about great fluctuations of unit load, steam temperature and pressure, accelerating scale shedding. In conclusion, preventive measures are drawn up considering the operation mode of the unit.
Cost of dressings for prevention of sacral pressure ulcers.
Inoue, Kelly Cristina; Matsuda, Laura Misue
2016-01-01
to identify costs of dressings to prevent sacral pressure ulcers in an adult intensive care unit in Paraná, Brazil. secondary analysis study with 25 patients admitted between October 2013 and March 2014, using transparent polyurethane film (n=15) or hydrocolloid dressing (n=10) on the sacral region. The cost of each intervention was based on the unit amount used in each type of dressing, and its purchase price (transparent film = R$15.80, hydrocolloid dressing = R$68.00). the mean cost/patient was R$23.17 for use of transparent film and R$190.40 for use of hydrocolloid dressing. The main reason for changing the dressing was detachment. the transparent film was the most economically advantageous alternative to prevent sacral pressure ulcers in critical care patients. However, additional studies should be carried out including assessment of the effectiveness of both dressings.
LASERS: Efficient chemical oxygen — iodine laser with a high total pressure of the active medium
NASA Astrophysics Data System (ADS)
Zagidullin, M. V.; Nikolaev, V. D.; Svistun, M. I.; Khvatov, N. A.; Heiger, G. D.; Madden, T. J.
2001-01-01
A new concept of obtaining a high total pressure of the active medium of a chemical oxygen — iodine laser (OIL) is proposed and verified. The nozzle unit of the laser consists of the alternating vertical arrays of cylindrical nozzles to produce high-pressure nitrogen jets, plane slotted nozzles for the flow of O2(1Δ) oxygen, and vertical arrays of cylindrical nozzles to inject the N2 — I2 mixture between the first two streams. For a molar chlorine flow rate of 39.2 mmol s-1, the output power was 700 W and the chemical efficiency was 19.7 %. The combined use of the ejector nozzle unit proposed to obtain the active medium and a super-sonic diffuser allows a significant simplification of the ejection system for the exhaust active medium of the OIL.
Code of Federal Regulations, 2011 CFR
2011-10-01
... second or less. Decibel (dB) means a unit of measurement of sound pressure levels. dB(A) means the sound... operate similar equipment under similar conditions. Sound level or Sound pressure level means ten times... an eight-hour time-weighted-average sound level (TWA) of 85 dB(A), or, equivalently, a dose of 50...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-06
... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-709 (Third Review)] Certain Seamless Carbon and Alloy Steel; Standard, Line, and Pressure Pipe From Germany Determination On the basis of the record \\1\\ developed in the subject five-year review, the United States International Trade Commission...
Reading, Writing, and Refreshments: Are School Finances Contributing to Children's Obesity?
ERIC Educational Resources Information Center
Anderson, Patricia M.; Butcher, Kristin F.
2006-01-01
Over the last two decades the proportion of adolescents in the United States who are obese has nearly tripled, and schools, citing financial pressures, have given students greater access to "junk" foods, using the proceeds to fund school programs. We examine whether schools under financial pressure tend to adopt potentially unhealthful…
202. Photocopy of drawing (1976 piping drawing by StearnsRoger Incorporated) ...
202. Photocopy of drawing (1976 piping drawing by Stearns-Roger Incorporated) HIGH PRESSURE GASEOUS NITROGEN AND HELIUM LINES FOR THE PAYLOAD PRESSURIZATION UNIT IN THE MST, SHEET 501-P2 - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
262. Photocopy of drawing (1976 piping drawing by StearnsRoger Incorporated) ...
262. Photocopy of drawing (1976 piping drawing by Stearns-Roger Incorporated) GLOBAL POSITIONING SYSTEM MODIFICATIONS, PAYLOAD PRESSURIZATION UNIT HIGH PRESSURE GASEOUS NITROGEN AND HELIUM LINES FOR LSB, SHEET 501-P3 - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
Unibody Composite Pressurized Structure (UCPS) for In-Space Propulsion
NASA Technical Reports Server (NTRS)
Rufer, Markus
2015-01-01
Microcosm, Inc., in conjunction with the Scorpius Space Launch Company, is developing a UCPS (Unibody Composite Pressurized Structure )for in-space propulsion. This innovative approach constitutes a clean break from traditional spacecraft design by combining what were traditionally separate primary and secondary support structures and metal propellant tanks into a single unit.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pokrovskii, V.A.
1999-04-01
Dissociation constants of aqueous ion pairs HCl{sup 0} and HBr{sup 0} derived in the literature from vapor pressure and supercritical conductance measurements (Quist and Marshall, 1968b; Frantz and Marshall, 1984) were used to calculate the standard partial molal thermodynamic properties of the species at 25 C and 1 bar. Regression of the data with the aid of revised Helgeson-Kirkham-Flowers equations of state (Helgeson et al., 1981; Tanger and Helgeson, 1988; Shock et al., 1989) resulted in a set of equations-of-state parameters that permits accurate calculation of the thermodynamic properties of the species at high temperatures and pressures. These properties andmore » parameters reproduce generally within 0.1 log unit (with observed maximum deviation of 0.23 log unit) the log K values for HBr{sup 0} and HCl{sup 0} given by Quist and Marshall (1968b) and Frantz and Marshall (1984), respectively, at temperatures to 800 C and pressures to 5 kbar.« less
Outflow monitoring of a pneumatic ventricular assist device using external pressure sensors.
Kang, Seong Min; Her, Keun; Choi, Seong Wook
2016-08-25
In this study, a new algorithm was developed for estimating the pump outflow of a pneumatic ventricular assist device (p-VAD). The pump outflow estimation algorithm was derived from the ideal gas equation and determined the change in blood-sac volume of a p-VAD using two external pressure sensors. Based on in vitro experiments, the algorithm was revised to consider the effects of structural compliance caused by volume changes in an implanted unit, an air driveline, and the pressure difference between the sensors and the implanted unit. In animal experiments, p-VADs were connected to the left ventricles and the descending aorta of three calves (70-100 kg). Their outflows were estimated using the new algorithm and compared to the results obtained using an ultrasonic blood flow meter (UBF) (TS-410, Transonic Systems Inc., Ithaca, NY, USA). The estimated and measured values had a Pearson's correlation coefficient of 0.864. The pressure sensors were installed at the external controller and connected to the air driveline on the same side as the external actuator, which made the sensors easy to manage.
Elevation effects in volcano applications of the COSPEC
Gerlach, T.M.
2003-01-01
Volcano applications commonly involve sizeable departures from the reference pressure and temperature of COSPEC calibration cells. Analysis shows that COSPEC SO2 column abundances and derived mass emission rates are independent of pressure and temperature, and thus unaffected by elevation effects related to deviations from calibration cell reference state. However, path-length concentrations are pressure and temperature dependent. Since COSPEC path-length concentration data assume the reference pressure and temperature of calibration cells, they can lead to large errors when used to calculate SO2 mixing ratios of volcanic plumes. Correction factors for COSPEC path-length concentrations become significant (c.10%) at elevations of about 1 km (e.g. Kilauea volcano) and rise rapidly to c.80% at 6 km (e.g. Cotopaxi volcano). Calculating SO2 mixing ratios for volcanic plumes directly from COSPEC path-length concentrations always gives low results. Corrections can substantially increase mixing ratios; for example, corrections increase SO2 ppm concentrations reported for the Mount St Helens, Colima, and Erebus plumes by 25-50%. Several arguments suggest it would be advantageous to calibrate COSPEC measurements in column abundance units rather than path-length concentration units.
Comparing the efficiency of supersonic oxygen-iodine laser with different mixing designs
NASA Astrophysics Data System (ADS)
Vyskubenko, Boris A.; Adamenkov, A. A.; Bakshin, V. V.; Efremov, V. I.; Ilyin, S. P.; Kolobyanin, Yu. V.; Krukovsky, I. M.; Kudryashov, E. A.; Moiseyev, V. B.
2003-11-01
The paper presents experimental studies of supersonic oxygen-iodine laser (OIL) using twisted-flow singlet oxygen generator (SOG) over a wide range of the singlet oxygen pressures and the buffer gas flow rates. The experiments used different designs of the nozzle unit and mixing system for singlet oxygen and iodine gas with the carrier gas (such as nitrogen or helium). For a wide range of the key parameters, the study looked at the efficiency of supersonic OIL with variation of the singlet oxygen pressure. The measurements were made for different positions of the iodine injection plane with respect to the critical cross-section (both in the subsonic part of the nozzle and in the supersonic flow). The gas pressure at the nozzle unit entry was varied from 50 to 250 Torr. The total pressure loss have been found for different mixing designs. Experimental curves are given for energy performance and chemical efficiency of the supersonic OIL as a function of the key parameters. Comparison is made between the calculated and experimental data. For the optimum conditions of OIL operation, chemical efficiency of 25-30% has been achieved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bhattacharyya, D.; Turton, R.; Zitney, S.
In this presentation, development of a plant-wide dynamic model of an advanced Integrated Gasification Combined Cycle (IGCC) plant with CO2 capture will be discussed. The IGCC reference plant generates 640 MWe of net power using Illinois No.6 coal as the feed. The plant includes an entrained, downflow, General Electric Energy (GEE) gasifier with a radiant syngas cooler (RSC), a two-stage water gas shift (WGS) conversion process, and two advanced 'F' class combustion turbines partially integrated with an elevated-pressure air separation unit (ASU). A subcritical steam cycle is considered for heat recovery steam generation. Syngas is selectively cleaned by a SELEXOLmore » acid gas removal (AGR) process. Sulfur is recovered using a two-train Claus unit with tail gas recycle to the AGR. A multistage intercooled compressor is used for compressing CO2 to the pressure required for sequestration. Using Illinois No.6 coal, the reference plant generates 640 MWe of net power. The plant-wide steady-state and dynamic IGCC simulations have been generated using the Aspen Plus{reg_sign} and Aspen Plus Dynamics{reg_sign} process simulators, respectively. The model is generated based on the Case 2 IGCC configuration detailed in the study available in the NETL website1. The GEE gasifier is represented with a restricted equilibrium reactor model where the temperature approach to equilibrium for individual reactions can be modified based on the experimental data. In this radiant-only configuration, the syngas from the Radiant Syngas Cooler (RSC) is quenched in a scrubber. The blackwater from the scrubber bottom is further cleaned in the blackwater treatment plant. The cleaned water is returned back to the scrubber and also used for slurry preparation. The acid gas from the sour water stripper (SWS) is sent to the Claus plant. The syngas from the scrubber passes through a sour shift process. The WGS reactors are modeled as adiabatic plug flow reactors with rigorous kinetics based on the mid-life activity of the shift-catalyst. The SELEXOL unit consists of the H2S and CO2 absorbers that are designed to meet the stringent environmental limits and requirements of other associated units. The model also considers the stripper for recovering H2S that is sent as a feed to a split-flow Claus unit. The tail gas from the Claus unit is recycled to the SELEXOL unit. The cleaned syngas is sent to the GE 7FB gas turbine. This turbine is modeled as per published data in the literature. Diluent N2 is used from the elevated-pressure ASU for reducing the NOx formation. The heat recovery steam generator (HRSG) is modeled by considering generation of high-pressure, intermediate-pressure, and low-pressure steam. All of the vessels, reactors, heat exchangers, and the columns have been sized. The basic IGCC process control structure has been synthesized by standard guidelines and existing practices. The steady-state simulation is solved in sequential-modular mode in Aspen Plus{reg_sign} and consists of more than 300 unit operations, 33 design specs, and 16 calculator blocks. The equation-oriented dynamic simulation consists of more than 100,000 equations solved using a multi-step Gear's integrator in Aspen Plus Dynamics{reg_sign}. The challenges faced in solving the dynamic model and key transient results from this dynamic model will also be discussed.« less
NASA Astrophysics Data System (ADS)
Avigad, D.
2007-12-01
The Aegean Sea, formed via extensional tectonics and floored by an attenuated continental crust, overprinted and dissected a once-continuous Alpine orogenic belt that stretched from mainland Greece to Anatolia. The Cycladic islands, in the central Aegean region, mainly comprise HP-LT metamorphic rocks (and their greenschist-facies derivatives) whose P-T conditions range at 12-15 kbars and 450-500 °C, straddling the blueschist-eclogite facies boundary. The protoliths are supracrustals metavolcanics and volcanoclastics alongside thick marble units that were deposited on the Pindos basin margin. Locally, such as on Syros and Sifnos, kilometer-thick, blueschist and eclogite-facies rocks are preserved intact allowing to explore the bottom of the orogenic edifice. 40Ar/39Ar ages of ~45Ma have been repeatedly obtained on Si rich phengites assessing the Eocene timing of the high-pressure metamorphism and crustal thickening. Upon decompression, the high- pressure rocks were overprinted in the greenschist-facies but locally as on Naxos migmatites were formed on the expense of eclogites at mid-crustal depth, at ~20 Ma. A series of granitoids penetrated the exhumed rock units during the Middle Miocene (until ~10Ma) in relation to whole-lithosphere back-arc extension.//The Cycladic blueschist belt, in the core of the extending Aegean region, is a suitable site to analyze the interplay between Mediterranean-type back-arc extension and the exhumation of the high-pressure metamorphic rocks. The Cycladic blueschist unit is sandwiched between lower pressure rocks: it is topped by greenschist- and amphibolite facies metamorphic rocks comprising metavolcanics interleaved with metamorphosed ultrabasic slices. The tectonic contact is a low-angle extensional detachment of significant lateral dimension and kinematic markers usually portray top-to-the-North sense of motion. Being stitched by mid-Miocene granitoids this is the oldest extensional discontinuity observed in the central Aegean. Where the original architecture of the Alpine orogenic belt was not severely obliterated, such as on Evia, a basal unit (Almyropotamos window) is exposed below the Cycladic blueschists unit. Within the basal unit, the presence of relict glaucophane and Si-rich phengite attest for a LT-HP metamorphism, but carbonates still preserve Lutetian nummullites indicating the basal unit metamorphism outlasted the Middle Eocene as well as cooling of the overlying Cycladic blueschists. The Cycladic blueschist unit is thus allochtonous on a regional scale: it was accreted into the orogenic wedge sometimes after the mid-Eocene. The time interval between the Eocene peak of eclogite metamorphism and the onset of back-arc extension in the Oligo-Miocene involved thrusting and contraction. In the central Aegean, the entire inventory of extensional structures operated subsequently to the emplacement of the Cycladic blueschist unit onto lower pressure sequences implying whole-lithosphere back-arc extension overprinted an Alpine orogen containing eclogites at relatively shallow structural levels. This resembles the mode of occurrence of eclogites in other mountain belts where back-arc extension played no role. Remarkably, despite significant crustal stretching only minor lateral metamorphic breaks can be identified in the Cyclades and the 12-15 kbar level of the former orogen are pervasively exposed over much of the archipelago.
ERIC Educational Resources Information Center
Lindstrom, Peter A.; And Others
This document consists of four units. The first of these views calculus applications to work, area, and distance problems. It is designed to help students gain experience in: 1) computing limits of Riemann sums; 2) computing definite integrals; and 3) solving elementary area, distance, and work problems by integration. The second module views…
1990-06-01
reduction software , prior to converting all remaining test which requires internal compensation. T he r sidual effect is pressures to engineering units...Reduction Conversion of Millivolts to Engineering Units. Carrying out numerical integrations to obtain area and mass weighted averages for various...Performance Assessment of Aircraft Turbine Engines and Components (Les MWthodes Recommande’es pour la Mesure de la Pression et de ]a Temperature de la
Overpressure, Low Effective Stress, and Slope Failure in the Ursa Region, Deep-Water Gulf of Mexico
NASA Astrophysics Data System (ADS)
Sawyer, D. E.; Flemings, P. B.
2004-12-01
Slope failures are associated with overpressured pore fluids and low effective stresses in the Quaternary strata of the Ursa Region, deep-water Gulf of Mexico. At Ursa, a permeable turbidite sandstone (the Blue Unit) is overlain by a low-permeability mudstone. Overpressure in the mudstone, measured with a pore pressure penetrometer (piezoprobe), begin within a few meters of the seafloor and extend 250-450 meters down to the Blue Unit. The overpressure ratio (λ *=(Pp-Phydrostatic)\\ (Sv-Phydrostatic), where Sv is the overburden stress, Pp is pore pressure, and Phydrostatic is the hydrostatic pressure) ranges from 0.8 where the overburden is thin to 0.4 where the overburden is thick. Detachment surfaces, mapped with high resolution 3D seismic data, are associated with zones where effective stresses are low. Four subsurface slumps were mapped and are oriented generally northwest-southeast. Slump surface areas are less than 250 km2 and maximum scarp-wall height on the largest slide is ˜120 meters. We interpret that asymmetric loading of the Blue Unit by low-permeable mudstone has driven fluids to where overburden is thin, decreased effective stress, and generated slope instability.
NASA Astrophysics Data System (ADS)
Zhu, D. C.; Su, C. Q.; Deng, Y. D.; Wang, Y. P.; Liu, X.
2017-11-01
Automotive exhaust-based thermoelectric generators are currently a hot topic in energy recovery. The waste heat of automotive exhaust gas can be converted into electricity by means of thermoelectric modules. Generally, inserting fins into the cooling unit contributes to enhancing the heat transfer for a higher power output. However, the introduction of fins will result in a pressure drop in the cooling system. In current research, in order to enhance the heat transfer and avoid a large pressure drop, a cooling unit with cylindrical grooves on the interior surface was proposed. To evaluate the performance of the cylindrical grooves, different inner topologies, including a smooth interior surface,a smooth interior surface with inserted fins and an interior surface with cylindrical grooves, were compared. The results revealed that compared with the smooth interior surface, the smooth interior surface with inserted fins and the interior surface with cylindrical grooves both enhanced the heat transfer, but the interior surface with cylindrical grooves obtained a lower pressure drop. To improve the performance of the cylindrical grooves, different groove-depth ratios were tried, and the results showed that a groove-depth ratio of 0.081 could provide the best overall performance.
NASA Astrophysics Data System (ADS)
Zhu, D. C.; Su, C. Q.; Deng, Y. D.; Wang, Y. P.; Liu, X.
2018-06-01
Automotive exhaust-based thermoelectric generators are currently a hot topic in energy recovery. The waste heat of automotive exhaust gas can be converted into electricity by means of thermoelectric modules. Generally, inserting fins into the cooling unit contributes to enhancing the heat transfer for a higher power output. However, the introduction of fins will result in a pressure drop in the cooling system. In current research, in order to enhance the heat transfer and avoid a large pressure drop, a cooling unit with cylindrical grooves on the interior surface was proposed. To evaluate the performance of the cylindrical grooves, different inner topologies, including a smooth interior surface,a smooth interior surface with inserted fins and an interior surface with cylindrical grooves, were compared. The results revealed that compared with the smooth interior surface, the smooth interior surface with inserted fins and the interior surface with cylindrical grooves both enhanced the heat transfer, but the interior surface with cylindrical grooves obtained a lower pressure drop. To improve the performance of the cylindrical grooves, different groove-depth ratios were tried, and the results showed that a groove-depth ratio of 0.081 could provide the best overall performance.
NASA Astrophysics Data System (ADS)
Butler, Thomas S.
Throughout the United States the electric utility industry is restructuring in response to federal legislation mandating deregulation. The electric utility industry has embarked upon an extraordinary experiment by restructuring in response to deregulation that has been advocated on the premise of improving economic efficiency by encouraging competition in as many sectors of the industry as possible. However, unlike the telephone, trucking, and airline industries, the potential effects of electric deregulation reach far beyond simple energy economics. This dissertation presents the potential safety risks involved with the deregulation of the electric power industry in the United States and abroad. The pressures of a competitive environment on utilities with nuclear power plants in their portfolio to lower operation and maintenance costs could squeeze them to resort to some risky cost-cutting measures. These include deferring maintenance, reducing training, downsizing staff, excessive reductions in refueling down time, and increasing the use of on-line maintenance. The results of this study indicate statistically significant differences at the .01 level between the safety of pressurized water reactor nuclear power plants and boiling water reactor nuclear power plants. Boiling water reactors exhibited significantly more problems than did pressurized water reactors.
New two-tier low pressure turbine for heavy duty steam turbines
NASA Astrophysics Data System (ADS)
Zaryankin, A. E.; Rogalev, A. N.; Osipov, S. K.; Bychkov, N. M.
2017-11-01
Among factors characterising steam turbine units of power plants, a specific metal content which value decreases inversely to turbine power is of substantive importance. In turn, their maximum power depends on the capacity of low pressure turbines. It is traditionally managed to increase either by installation of larger number of low pressure turbines or by lengthening the exhaust blades. It is worth noting that the above-mentioned methods have some technical restrictions by the number of rotors to be connected. Currently some works aimed at solving the stated technical problems appear in the literature for the purpose of increasing the unit power of turbomachines, for example, by using exhaust blades with the length of 1 500 mm and longer. However, it is to be understood that increasing the exhaust area of turbomachine only by lengthening exhaust blades cannot provide a cost-effective and reliable work of the turbine flow part. Here new problems appear: losses rise abruptly due to the stage fan-out, the turbomachine dimensions increase, etc. In this connection, an issue of development of new, technically implementable ways of turbo-units power increase is very acute today.
Stodtmeister, Richard; Ventzke, Sylvana; Spoerl, Eberhard; Boehm, Andreas G; Terai, Naim; Haustein, Michael; Pillunat, Lutz E
2013-07-12
The pressure in the central retinal vein (CRVP) has been shown to be higher in glaucoma patients than in controls. Until now, these measurements have been performed in arbitrary units or in units of ophthalmodynamometric force. In our study, a contact lens dynamometer, calibrated in mm Hg, was used to calculate the retinal perfusion pressure. A total of 27 patients with primary open angle glaucoma (POAG) and 27 healthy control subjects were included in the study. The IOP measurement included Goldmann applanation tonometry, whereas the pressure enhancement measurement consisted of contact lens dynamometry. results: the pressures are given in mm hg, and are expressed as the mean ± SD for the control subjects versus the POAG patients: IOP 14.4 ± 2.7 vs. 15.4 ± 2.9, systolic blood pressure 141 ± 20.1 vs. 153 ± 16.5 (P = 0.013), central retinal vein threshold pressure (CRVTP) 11.9 ± 3.8 vs. 16.8 ± 5.0, CRVP 15.0 ± 2.7 vs. 17.9 ± 4.2, and retinal perfusion pressure (PPret) standard 84 ± 12.2 vs. 94 ± 9.1 and new 83 ± 12.2 vs. 91 ± 9.6. The differences in PPret between using the new versus the standard method are 0.55 ± 1.33 vs. -2.5 ± 3.89 (P = 0.041 and P = 0.002, respectively). The PPret was at least 5.0 mm Hg lower in 5 of the 27 POAG patients when the new calculation method was used. The perfusion pressure in the retina and prelaminar region of the optic nerve head (ONH) may be lower than expected because the CRVP may be higher. The pressure measurement in the central retinal vein may be a step toward a better understanding of ONH pathophysiology.
High-pressure transformation in the cobalt spinel ferrites
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blasco, J., E-mail: jbc@posta.unizar.es; Subías, G.; García, J.
2015-01-15
We report high pressure angle-dispersive x-ray diffraction measurements on Co{sub x}Fe{sub 3−x}O{sub 4} (x=1, 1.5, 1.75) spinels at room temperature up to 34 GPa. The three samples show a similar structural phase transformation from the cubic spinel structure to an analogous post-spinel phase at around 20 GPa. Spinel and post-spinel phases coexist in a wide pressure range (∼20–25 GPa) and the transformation is irreversible. The equation of state of the three cubic spinel ferrites was determined and our results agree with the data obtained in related oxide spinels showing the role of the pressure-transmitting medium for the accurate determination ofmore » the equation of state. Measurements releasing pressure revealed that the post-spinel phase is stable down to 4 GPa when it decomposes yielding a new phase with poor crystallinity. Later compression does not recover either the spinel or the post-spinel phases. This phase transformation induced by pressure explains the irreversible lost of the ferrimagnetic behavior reported in these spinels. - Graphical abstract: Pressure dependence of the unit cell volume per formula unit for Co{sub 1.5}Fe{sub 1.5}O{sub 4} spinel. Circles and squares stand for spinel and postspinel phases, respectively. Dark (open) symbols: determination upon compression (decompression). - Highlights: • The pressure induces similar phase transformation in Co{sub 3−x}Fe{sub x}O{sub 4} spinels (1≤x≤2). • The postspinel phases decompose after releasing pressure. • The irreversibility of this phase transformation explains the disappearance of magnetism in these spinels after applying pressure. • Accurate equation of state can be obtained up to 10 GPa using an alcohol mixture as pressure transmitting medium. • The equation of state suggests similar elastic properties for these spinels in this composition range.« less
Evaluation of Acoustic Emission SHM of PRSEUS Composite Pressure Cube Tests
NASA Technical Reports Server (NTRS)
Horne, Michael R.; Madaras, Eric I.
2013-01-01
A series of tests of the Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) pressure cube were conducted during third quarter 2011 at NASA Langley Research Center (LaRC) in the Combined Loads Test facility (COLTS). This is a report of the analysis of the Acoustic Emission (AE) data collected during those tests. The AE signals of the later tests are consistent with the final failure progression through two of the pressure cube panels. Calibration tests and damage precursor AE indications, from preliminary checkout pressurizations, indicated areas of concern that eventually failed. Hence those tests have potential for vehicle health monitoring.
2009-12-01
pressure transducers were calibrated (designated INLET and EXIT) using a portable pressure calibrator ( Druck , DPI 610). The unit has an accuracy of 0.025...of full scale (fs) with macro and micro pressure adjustment capabilities. The Druck pressure range was 14.7-300 psia. The transducers (Omega PX303...050A5V) had a range of 0-50 psig with an output voltage of 0.5-5 VDC. The inlet and exit transducers were calibrated separately using the Druck
Numerical simulation of aerodynamic performance of a couple multiple units high-speed train
NASA Astrophysics Data System (ADS)
Niu, Ji-qiang; Zhou, Dan; Liu, Tang-hong; Liang, Xi-feng
2017-05-01
In order to determine the effect of the coupling region on train aerodynamic performance, and how the coupling region affects aerodynamic performance of the couple multiple units trains when they both run and pass each other in open air, the entrance of two such trains into a tunnel and their passing each other in the tunnel was simulated in Fluent 14.0. The numerical algorithm employed in this study was verified by the data of scaled and full-scale train tests, and the difference lies within an acceptable range. The results demonstrate that the distribution of aerodynamic forces on the train cars is altered by the coupling region; however, the coupling region has marginal effect on the drag and lateral force on the whole train under crosswind, and the lateral force on the train cars is more sensitive to couple multiple units compared to the other two force coefficients. It is also determined that the component of the coupling region increases the fluctuation of aerodynamic coefficients for each train car under crosswind. Affected by the coupling region, a positive pressure pulse was introduced in the alternating pressure produced by trains passing by each other in the open air, and the amplitude of the alternating pressure was decreased by the coupling region. The amplitude of the alternating pressure on the train or on the tunnel was significantly decreased by the coupling region of the train. This phenomenon did not alter the distribution law of pressure on the train and tunnel; moreover, the effect of the coupling region on trains passing by each other in the tunnel is stronger than that on a single train passing through the tunnel.
Photoelastic analysis in respect to failure mechanics problems of power plant articles and units
NASA Astrophysics Data System (ADS)
Korikhin, N. V.; Eigenson, S. N.
2009-02-01
The results of strength tests of some critical articles and units of power plants, i.e., a reactor vessel, threaded connection of vessel split, pressure header with straight nipple, turbomachine shaft, and T-weld joint of stator and rotor parts, of turbomachines are presented.
78 FR 54739 - National Childhood Obesity Awareness Month, 2013
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-06
... National Childhood Obesity Awareness Month, 2013 By the President of the United States of America A Proclamation In the United States, obesity affects millions of children and teenagers, raising their risk of... pressure. While childhood obesity remains a serious public health issue, we have made significant strides...
Diesel Fuel Systems. Teacher Edition (Revised).
ERIC Educational Resources Information Center
Clark, Elton; Huston, Jane, Ed.
This module is one of a series of teaching guides that cover diesel mechanics. The module contains six instructional units that cover the following topics: (1) introduction to fuel injection systems and components; (2) injection nozzles; (3) distributor type injection pumps; (4) unit injectors; (5) in-line injection pumps; and (6) pressure timed…
Stored grain pack factors for wheat: comparison of three methods to field measurements
USDA-ARS?s Scientific Manuscript database
Storing grain in bulk storage units results in grain packing from overbearing pressure, which increases grain bulk density and storage-unit capacity. This study compared pack factors of hard red winter (HRW) wheat in vertical storage bins using different methods: the existing packing model (WPACKING...
Transformational Leadership in the Educational System of the United Arab Emirates
ERIC Educational Resources Information Center
Litz, David; Scott, Shelleyann
2017-01-01
Globally, there is increasing pressure on schools to enact change, and the literature indicates that transformational leadership is positively associated with school leaders' effectiveness at implementing positive reforms. Here, we report on a study conducted in the United Arab Emirates (UAE) within the current context of intense educational…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-04
... Design,'' GDC 31, ``Fracture Prevention of Reactor Coolant Pressure Boundary,'' and GDC 32, ``Inspection... Operating Company; Vogtle Electric Generating Plant, Unit Nos. 1 and 2; Notice of Consideration of Issuance of Amendment to Facility Operating License, Proposed No Significant Hazards Consideration...
NASA Technical Reports Server (NTRS)
Nelson, N. W.
1975-01-01
The application of NASTRAN to the design of a fluid solids unit plenum/cyclone/dipleg assembly is described. The major loads considered are thermal, pressure, and gravity. Such applications are of interest in the petroleum industry since the equipment described is historically critical.
49 CFR 232.103 - General requirements for all train brake systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... the air compressor governor starting or loading pressure. (l) Except as otherwise provided in this... equipment” means equipment left standing and unmanned in such a manner that the brake system of the... unit of the equipment left unattended. (3) Except for distributed power units, the following...
Tissue-Informative Mechanism for Wearable Non-invasive Continuous Blood Pressure Monitoring
NASA Astrophysics Data System (ADS)
Woo, Sung Hun; Choi, Yun Young; Kim, Dae Jung; Bien, Franklin; Kim, Jae Joon
2014-10-01
Accurate continuous direct measurement of the blood pressure is currently available thru direct invasive methods via intravascular needles, and is mostly limited to use during surgical procedures or in the intensive care unit (ICU). Non-invasive methods that are mostly based on auscultation or cuff oscillometric principles do provide relatively accurate measurement of blood pressure. However, they mostly involve physical inconveniences such as pressure or stress on the human body. Here, we introduce a new non-invasive mechanism of tissue-informative measurement, where an experimental phenomenon called subcutaneous tissue pressure equilibrium is revealed and related for application in detection of absolute blood pressure. A prototype was experimentally verified to provide an absolute blood pressure measurement by wearing a watch-type measurement module that does not cause any discomfort. This work is supposed to contribute remarkably to the advancement of continuous non-invasive mobile devices for 24-7 daily-life ambulatory blood-pressure monitoring.
Visible-Light Resin Curing Units.
1984-03-01
dental unit’s pilot or drive air pressure, and is activated via the foot control that also operates the high-speed and low-speed handpieces . For all...the Dental Investigation Sqtc* kvmtc)b Cini’cal Sciences Division, USAF School of Aerospace 114,~e Ameoae ~dical Division, APSC, Brooks Air force... Dental curing units White light activation II Visible-light activation 19. AISTRACT (Continue on ,werse if necenawy and identify by
Chronically implanted pressure sensors: challenges and state of the field.
Yu, Lawrence; Kim, Brian J; Meng, Ellis
2014-10-31
Several conditions and diseases are linked to the elevation or depression of internal pressures from a healthy, normal range, motivating the need for chronic implantable pressure sensors. A simple implantable pressure transduction system consists of a pressure-sensing element with a method to transmit the data to an external unit. The biological environment presents a host of engineering issues that must be considered for long term monitoring. Therefore, the design of such systems must carefully consider interactions between the implanted system and the body, including biocompatibility, surgical placement, and patient comfort. Here we review research developments on implantable sensors for chronic pressure monitoring within the body, focusing on general design requirements for implantable pressure sensors as well as specifications for different medical applications. We also discuss recent efforts to address biocompatibility, efficient telemetry, and drift management, and explore emerging trends.
Water hammer effect in the spiral case and penstock of Francis turbines
NASA Astrophysics Data System (ADS)
Pepa, D.; Ursoniu, C.; Gillich, R. N.; Campian, C. V.
2017-01-01
Sudden pressure increases in the penstock or spiral case of a hydraulic turbine are the effect of sudden flow variation that occur during transient processes of type opening / closing or load rejection of the hydro unit. The consequence of the pressure rise in the spiral case and penstock is the water hammer phenomenon, whose effects can be devastating in some cases, up to breaking pipes and calamities produced in the area. This paper aims to analyze the method of calculation of the maximum pressure values that might occur in load rejection situations to a hydraulic turbine, in spiral case and in penstock, conditioned by the limiting of the values of the over speed and measures of limiting the increase in pressure in conjunction with limiting the increase in speed in these specific processes. As an example, we studied and analyzed the situation of a hydroelectric power plant equipped with a 7.8 MW Francis turbine without pressure regulator and the inflow surge. The results of analytical calculation overlaid on the experimental measurements performed during the performance tests of the hydro unit lead to the conclusion that the calculation algorithm proposed has been chosen correctly and the 2-stage closing law of the wicket gate promoted in this case is effective in such situations.
Api, Olus; Balcin, Muge Emeksiz; Ugurel, Vedat; Api, Murat; Turan, Cem; Unal, Orhan
2009-01-01
To determine the effect of uterine fundal pressure on shortening the second stage of labor and on the fetal outcome. Randomized controlled trial. Teaching and research hospital. One hundred ninety-seven women between 37 and 42 gestational weeks with singleton cephalic presentation admitted to the delivery unit. Random allocation into groups with or without manual fundal pressure during the second stage of labor. The primary outcome measure was the duration of the second stage of labor. Secondary outcome measures were umbilical artery pH, HCO3-, base excess, pO2, pCO2 values and the rate of instrumental delivery, severe maternal morbidity/mortality, neonatal trauma, admission to neonatal intensive care unit, and neonatal death. There were no significant differences in the mean duration of the second stage of labor and secondary outcome measures except for mean pO2 which was lower and mean pCO2 which was higher in the fundal pressure group. Nevertheless, the values still remained within normal ranges and there were no neonates with an Apgar score <7 in either of the groups. Application of fundal pressure on a delivering woman was ineffective in shortening the second stage of labor.
Prototype Development of an Implantable Compliance Chamber for a Total Artificial Heart.
Schmitz, Stephanie; Unthan, Kristin; Sedlaczek, Marc; Wald, Felix; Finocchiaro, Thomas; Spiliopoulos, Sotirios; Koerfer, Reiner; Steinseifer, Ulrich
2017-02-01
At our institute a total artificial heart is being developed. It is directly actuated by a linear drive in between two ventricles, which comprise membranes to separate the drive and blood flow. A compliance chamber (CC) is needed to reduce pressure peaks in the ventricles and to increase the pump capacity. Therefore, the movement of the membrane is supported by applying a negative pressure to the air volume inside the drive unit. This study presents the development of the implantable CC which is connected to the drive unit of the total artificial hearts (TAH). The anatomical fit of the CC is optimized by analyzing CT data and adapting the outer shape to ensure a proper fit. The pressure peaks are reduced by the additional volume and the flexible membrane of the CC. The validation measurements of change in pressure peaks and flow are performed using the complete TAH system connected to a custom mock circulation loop. Using the CC, the pressure peaks could be damped below 5 mm Hg in the operational range. The flow output was increased by up to 14.8% on the systemic side and 18.2% on the pulmonary side. The described implantable device can be used for upcoming chronic animal trials. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Transition Within Leeward Plane of Axisymmetric Bodies at Incidence in Supersonic Flow
NASA Technical Reports Server (NTRS)
Tokugawa, Naoko; Choudhari, Meelan; Ishikawa, Hiroaki; Ueda, Yoshine; Fujii, Keisuke; Atobe, Takashi; Li, Fei; Chang, Chau-Lyan; White, Jeffery
2012-01-01
Boundary layer transition along the leeward symmetry plane of axisymmetric bodies at nonzero angle of attack in supersonic flow was investigated experimentally and numerically as part of joint research between the Japan Aerospace Exploration Agency (JAXA) and National Aeronautics and Space Administration (NASA). Transition over four axisymmetric bodies (namely, Sears-Haack body, semi-Sears-Haack body, straight cone and flared cone) with different axial pressure gradients was measured in two different facilities with different unit Reynolds numbers. The semi-Sears-Haack body and flared cone were designed at JAXA to broaden the range of axial pressure distributions. For a body shape with an adverse pressure gradient (i.e., flared cone), the experimentally measured transition patterns show an earlier transition location along the leeward symmetry plane in comparison with the neighboring azimuthal locations. For nearly zero pressure gradient (i.e.,straight cone), this feature is only observed at the larger unit Reynolds number. Later transition along the leeward plane was observed for the remaining two body shapes with a favorable pressure gradient. The observed transition patterns are only partially consistent with the numerical predictions based on linear stability analysis. Additional measurements are used in conjunction with the stability computations to explore the phenomenon of leeward line transition and the underlying transition mechanism in further detail.
Kelleher, Alyson Dare; Moorer, Amanda; Makic, MaryBeth Flynn
2012-01-01
We conducted a quality improvement project in order to evaluate the effect of nurse-to-nurse bedside "rounding" as a strategy to decrease hospital-acquired pressure ulcers (HAPU) in a surgical intensive care unit. We instituted weekly peer-to-peer bedside skin rounds in a 17-bed surgical intensive care unit. Two nurses were identified as skin champions and trained by the hospital's certified WOC nurse to conduct skin rounds. The skin champion nurses conducted weekly peer-to-peer rounds that included discussions about key elements of our patients' skin status including current Braden Scale for Pressure Sore Risk score, and implementation of specific interventions related to subscale risk assessment. If a pressure ulcer was present, the current action plan was reevaluated for effectiveness. Quarterly HAPU prevalence studies were conducted from January 2008 to December 2010. Nineteen patients experienced a HAPU: 17 were located on the coccyx and 2 on the heel. Ten ulcers were classified as stage II, 3 PU were stage IV, 5 were deemed unstageable, and 1 was classified as a deep tissue injury. The frequency of preventive interventions rose during our quality improvement project. Specifically, the use of prevention surfaces increased 92%, repositioning increased 30%, nutrition interventions increased 77%, and moisture management increased 100%. Prior to focused nursing rounds, the highest HAPU prevalence rate was 27%. After implementing focused nursing rounds, HAPU rates trended down and were 0% for 3 consecutive quarters.
Relation between lowered colloid osmotic pressure, respiratory failure, and death.
Tonnesen, A S; Gabel, J C; McLeavey, C A
1977-01-01
Plasma colloid osmotic pressure was measured each day in 84 intensive care unit patients. Probit analysis demonstrated a direct relationship between colloid osmotic pressure (COP) and survival. The COP associated with a 50% survival rate was 15.0 torr. COP was higher in survivors than in nonsurvivors without respiratory failure and in patients who recovered from respiratory failure. We conclude that lowered COP is associated with an elevated mortality rate. However, the relationship to death is not explained by the relationship to respiratory failure.
Sour pressure swing adsorption process
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bhadra, Shubhra Jyoti; Wright, Andrew David; Hufton, Jeffrey Raymond
Methods and apparatuses for separating CO.sub.2 and sulfur-containing compounds from a synthesis gas obtained from gasification of a carbonaceous feedstock. The primary separating steps are performed using a sour pressure swing adsorption (SPSA) system, followed by an acid gas enrichment system and a sulfur removal unit. The SPSA system includes multiple pressure equalization steps and a rinse step using a rinse gas that is supplied from a source other than directly from one of the adsorber beds of the SPSA system.
Induction powered biological radiosonde
NASA Technical Reports Server (NTRS)
Fryer, T. B. (Inventor)
1980-01-01
An induction powered implanted monitor for epidurally measuring intracranial pressure and telemetering the pressure information to a remote readout is disclosed. The monitor utilizes an inductance-capacitance (L-C) oscillator in which the C comprises a variable capacitance transducer, one electrode of which is a small stiff pressure responsive diaphragm. The oscillator is isolated from a transmitting tank circuit by a buffer circuit and all electric components in the implanted unit except an input and an output coil are shielded by a metal housing.
2007-08-31
Element type Hex, independent meshing, Linear 3D stress Hex, independent meshing, Linear 3D stress 1 English Units were used in ABAQUS The NACA...Flow Freestream Condition Instrumentation Test section conditions were measured using a Druck DPI 203 digital pressure gage and an Omega Model 199...temperature gage. The Druck pressure gage measures the set dynamic pressure within 0.08%± of full scale, and the Omega thermometer is accurate to
Verification of the Chesapeake Bay Model.
1981-12-01
points on the model. Each inflow control unit consists of a pressure regulator , a digital flow control valve, and a flowmeter (Fig- ure 8). A mechanical...spring-type pressure regulator ensures constant pressure to the digital flow control valve. Each digital valve contains eight solenoid valve actuators...FT) =0.798 EEOC 1DGS 2.78 EPOCH (DEGS) - 11. 84 3 DATA TAKEN: AC(0) = 0. 11 38 F T A (0)= 0. 1653 FT 28 MAR 1978 RANGE (FT) - 1.638 RANGE (FT
Coleman during ICV Assessment in the Kibo JPM during Expedition 26
2011-01-07
ISS026-E-015923 (7 Jan. 2011) --- NASA astronaut Catherine (Cady) Coleman, Expedition 26 flight engineer, participates in the ambulatory monitoring part of the Integrated Cardiovascular (ICV) assessment research experiment in the Kibo laboratory of the International Space Station. Coleman is wearing electrodes, a Holter Monitor 2 (HM2) for recording Electrocardiogram (ECG), a European Space Agency (ESA) Cardio pressure / Blood Pressure unit to continuously monitor blood pressure and two Actiwatches (hip/waist and ankle) for monitoring activity levels.
Diedenhofen, Michael; Klamt, Andreas; Marsh, Kenneth; Schäfer, Ansgar
2007-09-07
The vapor pressures and vaporization enthalpies of a series of 1-n-alkyl-3-methylimidazolium-bis-(trifluoromethanesulfonyl) amide ionic liquids have been predicted with two different approaches using the COSMO-RS method and quantum chemical gas phase calculations. While the calculated enthalpies are in good agreement with the experimental data, COSMO-RS seems to underestimate the vapor pressures by roughly 0.5-4 log units dependent on the IL and approach used.
Quasi-Porous Plug With Vortex Chamber
NASA Technical Reports Server (NTRS)
Walsh, J. V.
1985-01-01
Pressure-letdown valve combines quasi-porous-plug and vortex-chamber in one controllable unit. Valve useful in fossil-energy plants for reducing pressures in such erosive two-phase process streams as steam/water, coal slurries, or combustion gases with entrained particles. Quasi-Porous Plug consists of plenums separated by perforated plates. Number or size of perforations increases with each succeeding stage to compensate for expansion. In Vortex Chamber, control flow varies to control swirl and therefore difference between inlet and outlet pressures.
Design and process integration of organic Rankine cycle utilizing biomass for power generation
NASA Astrophysics Data System (ADS)
Ependi, S.; Nur, T. B.
2018-02-01
Indonesia has high potential biomass energy sources from palm oil mill industry activities. The growing interest on Organic Rankine Cycle (ORC) application to produce electricity by utilizing biomass energy sources are increasingly due to its successfully used for generating electricity from rejected waste heat to the environment in industrial processes. In this study, the potential of the palm oil empty fruit bunch, and wood chip have been used as fuel for biomass to generate electricity based ORC with combustion processes. The heat from combustion burner was transfer by thermal oil heater to evaporate ORC working fluid in the evaporator unit. The Syltherm-XLT thermal oil was used as the heat carrier from combustion burner, while R245fa was used as the working fluid for ORC unit. Appropriate designs integration from biomass combustion unit to ORC unit have been analyzed and proposed to generate expander shaft-work. Moreover, the effect of recuperator on the total system efficiency has also been investigated. It was observed that the fuel consumption was increased when the ORC unit equipped recuperator operated until certain pressure and decreased when operated at high pressure.
Enhanced methods for operating refueling station tube-trailers to reduce refueling cost
DOE Office of Scientific and Technical Information (OSTI.GOV)
Elgowainy, Amgad; Reddi, Krishna
A method and apparatus are provided for operating a refueling station including source tube-trailers and at least one compressor to reduce refueling cost. The refueling station includes a gaseous fuel supply source including a plurality of tanks on a tube trailer coupled to a first control unit, and high pressure buffer storage having predefined capacity coupled to a second control unit and the first tanks by a pressure control valve and the first control unit, and at least one compressor. The refueling station is operated at different modes depending on a state of the refueling station at the beginning ofmore » each operational mode. The refueling system is assessed at the end of each operational mode to identify the state of the system and select a next mode of operation. The operational modes include consolidating hydrogen, or any gaseous fuel, within the tubes mounted on the trailer.« less
Ham, H W Wietske; Schoonhoven, L Lisette; Schuurmans, M Marieke J; Leenen, L Luke P H
2017-01-01
To explore the influence of risk factors present at Emergency Department admission on pressure ulcer development in trauma patients with suspected spinal injury, admitted to the hospital for evaluation and treatment of acute traumatic injuries. Prospective cohort study setting level one trauma center in the Netherlands participants adult trauma patients transported to the Emergency Department on a backboard, with extrication collar and headblocks and admitted to the hospital for treatment or evaluation of their injuries. Between January and December 2013, 254 trauma patients were included. The following dependent variables were collected: Age, Skin color and Body Mass Index, and Time in Emergency Department, Injury Severity Score, Mean Arterial Pressure, hemoglobin level, Glasgow Coma Score, and admission ward after Emergency Department. Pressure ulcer development during admission was associated with a higher age (p 0.00, OR 1.05) and a lower Glasgow Coma Scale score (p 0.00, OR 1.21) and higher Injury Severity Scores (p 0.03, OR 1.05). Extra nutrition decreases the probability of PU development during admission (p 0.04, OR 0.20). Pressure ulcer development within the first 48h of admission was positively associated with a higher age (p 0.01, OR 1.03) and a lower Glasgow Coma Scale score (p 0.01, OR 1.16). The proportion of patients admitted to the Intensive Care Unit and Medium Care Unit was higher in patients with pressure ulcers. The pressure ulcer risk during admission is high in patients with an increased age, lower Glasgow Coma Scale and higher Injury Severity Score in the Emergency Department. Pressure ulcer risk should be assessed in the Emergency Department to apply preventive interventions in time. Copyright © 2016 Elsevier Ltd. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-15
... Rocks for Engineering Analysis and Design of Nuclear Power Plants.'' In this exemption request, the... the design of the wall. Hence, the staff concludes that, the resulting static and dynamic earth pressures will be bounded by the lateral earth pressures used in design. Bearing Capacity The applicant...
Carrying the Beacon of Excellence: Social Class Differentiation and Anxiety at a Time of Transition.
ERIC Educational Resources Information Center
Lucey, Helen; Reay, Diane
2002-01-01
Examines ways in which current United Kingdom school-choice policies interact with parental pressures on their children to achieve excellence and how these pressures affect the emotional health of their middle- and working-class children as they make the transition from primary to secondary school. Finds serious emotional consequences (exam…
ERIC Educational Resources Information Center
Melnyk, J. A.; Panza, G.; Zaleski, A.; Taylor, B.
2015-01-01
Background: Cardiovascular disease (CVD) is the leading cause of death in the United States, yet knowledge of CVD risk factors is surprisingly low in college students. Purpose: The purpose of this study was to determine the effectiveness of an individualized blood pressure, cholesterol, and CVD education intervention on college freshmen. Methods:…
46 CFR 58.25-20 - Piping for steering gear.
Code of Federal Regulations, 2011 CFR
2011-10-01
... MACHINERY AND RELATED SYSTEMS Steering Gear § 58.25-20 Piping for steering gear. (a) Pressure piping must comply with subpart 58.30 of this part. (b) Relief valves must be fitted in any part of a hydraulic system that can be isolated and in which pressure can be generated from the power units or from external...
46 CFR 58.25-20 - Piping for steering gear.
Code of Federal Regulations, 2013 CFR
2013-10-01
... MACHINERY AND RELATED SYSTEMS Steering Gear § 58.25-20 Piping for steering gear. (a) Pressure piping must comply with subpart 58.30 of this part. (b) Relief valves must be fitted in any part of a hydraulic system that can be isolated and in which pressure can be generated from the power units or from external...
46 CFR 58.25-20 - Piping for steering gear.
Code of Federal Regulations, 2012 CFR
2012-10-01
... MACHINERY AND RELATED SYSTEMS Steering Gear § 58.25-20 Piping for steering gear. (a) Pressure piping must comply with subpart 58.30 of this part. (b) Relief valves must be fitted in any part of a hydraulic system that can be isolated and in which pressure can be generated from the power units or from external...
46 CFR 58.25-20 - Piping for steering gear.
Code of Federal Regulations, 2010 CFR
2010-10-01
... MACHINERY AND RELATED SYSTEMS Steering Gear § 58.25-20 Piping for steering gear. (a) Pressure piping must comply with subpart 58.30 of this part. (b) Relief valves must be fitted in any part of a hydraulic system that can be isolated and in which pressure can be generated from the power units or from external...
46 CFR 58.25-20 - Piping for steering gear.
Code of Federal Regulations, 2014 CFR
2014-10-01
... MACHINERY AND RELATED SYSTEMS Steering Gear § 58.25-20 Piping for steering gear. (a) Pressure piping must comply with subpart 58.30 of this part. (b) Relief valves must be fitted in any part of a hydraulic system that can be isolated and in which pressure can be generated from the power units or from external...
1982-05-01
insufficient need for a hard metric version of the ASME Boiler and Pressure Vessel Code and industry would not support the metric version. The Code Is not...aircraft industry is concerned with certification requirements in metric units. The inch-pound Boiler and Pressure Vessel Code is the current standard
Atmospheric moisture's influence on fire behavior: surface moisture and plume dynamics.
Brian E. Potter; Joseph J. Charney; Lesley A. Fusina
2006-01-01
Nine measures of atmospheric surface moisture are tested for statistical relationships with fire size and number of fires using data from the Great Lakes region of the United States. The measures include relative humidity, water vapor mixing ratio, mixing ratio deficit, vapor pressure, vapor pressure deficit, dew point temperature, dew point depression, wet bulb...
Exhaust Composition in a Small Internal Combustion Engine Using FTIR Spectroscopy
2015-06-18
ects of broadband sooting on IRF transmittance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 xi...IndiSmart combustion analyzer. This system conducted data acquisition on various high speed sensors including in- cylinder pressure, intake pressure...Crankshaft position was measured once per revolution by a hall-e↵ect sensor connected to the ignition 56 control unit. The engines were air cooled with
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-17
... Montana residents a high-quality option for their health insurance, routinely pressuring Blue Cross to... reputation for high-quality customer service. 36. Since the Agreement was announced in August 2011, many... offered Montana residents a high-quality option for their health insurance, routinely pressuring Blue...
2012-04-12
1 Effect Of Intake Pressure And Temperature On Auto-Ignition Of Fuels With Different Cetane Number And Volatility C. Jayakumar , U. Joshi, Z...AUTHOR(S) Eric Sattler; C. Jayakumar ; U. Joshi; Z. Zheng; W. Bryzik 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING
40 CFR Table 3 to Subpart Dddd of... - Model Rule-Operating Limits for Wet Scrubbers
Code of Federal Regulations, 2010 CFR
2010-07-01
... Scrubbers 3 Table 3 to Subpart DDDD of Part 60 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...—Model Rule—Operating Limits for Wet Scrubbers For these operating parameters You must establish these... intermittent units) a Pressure drop across the wet scrubber or amperage to wet scrubber Minimum pressure drop...
40 CFR Table 3 to Subpart Dddd of... - Model Rule-Operating Limits for Wet Scrubbers
Code of Federal Regulations, 2011 CFR
2011-07-01
... Scrubbers 3 Table 3 to Subpart DDDD of Part 60 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...—Model Rule—Operating Limits for Wet Scrubbers For these operating parameters You must establish these... intermittent units) a Pressure drop across the wet scrubber or amperage to wet scrubber Minimum pressure drop...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cho, M; Kim, T; Kang, S
Purpose: The purpose of this work is to develop a new patient set-up monitoring system using force sensing resistor (FSR) sensors that can confirm pressure of contact surface and evaluate its feasibility. Methods: In this study, we focused on develop the patient set-up monitoring system to compensate for the limitation of existing optical based monitoring system, so the developed system can inform motion in the radiation therapy. The set-up monitoring system was designed consisting of sensor units (FSR sensor), signal conditioning devices (USB cable/interface electronics), a control PC, and a developed analysis software. The sensor unit was made by attachingmore » FSR sensor and dispersing pressure sponge to prevent error which is caused by concentrating specific point. Measured signal from the FSR sensor was sampled to arduino mega 2560 microcontroller, transferred to control PC by using serial communication. The measured data went through normalization process. The normalized data was displayed through the developed graphic user interface (GUI) software. The software was designed to display a single sensor unit intensity (maximum 16 sensors) and display 2D pressure distribution (using 16 sensors) according to the purpose. Results: Changes of pressure value according to motion was confirmed by the developed set-up monitoring system. Very small movement such as little physical change in appearance can be confirmed using a single unit and using 2D pressure distribution. Also, the set-up monitoring system can observe in real time. Conclusion: In this study, we developed the new set-up monitoring system using FSR sensor. Especially, we expect that the new set-up monitoring system is suitable for motion monitoring of blind area that is hard to confirm existing optical system and compensate existing optical based monitoring system. As a further study, an integrated system will be constructed through correlation of existing optical monitoring system. This work was supported by the Industrial R&D program of MOTIE/KEIT. [10048997, Development of the core technology for integrated therapy devices based on real-time MRI guided tumor tracking] and the Mid-career Researcher Program (2014R1A2A1A10050270) through the National Research Foundation of Korea funded by the Ministry of Science, ICT&Future Planning.« less
Using wave intensity analysis to determine local reflection coefficient in flexible tubes.
Li, Ye; Parker, Kim H; Khir, Ashraf W
2016-09-06
It has been shown that reflected waves affect the shape and magnitude of the arterial pressure waveform, and that reflected waves have physiological and clinical prognostic values. In general the reflection coefficient is defined as the ratio of the energy of the reflected to the incident wave. Since pressure has the units of energy per unit volume, arterial reflection coefficient are traditionally defined as the ratio of reflected to the incident pressure. We demonstrate that this approach maybe prone to inaccuracies when applied locally. One of the main objectives of this work is to examine the possibility of using wave intensity, which has units of energy flux per unit area, to determine the reflection coefficient. We used an in vitro experimental setting with a single inlet tube joined to a second tube with different properties to form a single reflection site. The second tube was long enough to ensure that reflections from its outlet did not obscure the interactions of the initial wave. We generated an approximately half sinusoidal wave at the inlet of the tube and took measurements of pressure and flow along the tube. We calculated the reflection coefficient using wave intensity (R dI and R dI 0.5 ) and wave energy (R I and R I 0.5 ) as well as the measured pressure (R dP ) and compared these results with the reflection coefficient calculated theoretically based on the mechanical properties of the tubes. The experimental results show that the reflection coefficients determined by all the techniques we studied increased or decreased with distance from the reflection site, depending on the type of reflection. In our experiments, R dP , R dI 0.5 and R I 0.5 are the most reliable parameters to measure the mean reflection coefficient, whilst R dI and R I provide the best measure of the local reflection coefficient, closest to the reflection site. Additional work with bifurcations, tapered tubes and in vivo experiments are needed to further understand, validate the method and assess its potential clinical use. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Effects of Oxygen Partial Pressure on the Surface Tension of Liquid Nickel
NASA Technical Reports Server (NTRS)
SanSoucie, Michael P.; Rogers, Jan R.; Gowda, Vijaya Kumar Malahalli Shankare; Rodriguez, Justin; Matson, Douglas M.
2015-01-01
The NASA Marshall Space Flight Center's electrostatic levitation (ESL) laboratory has been recently upgraded with an oxygen partial pressure controller. This system allows the oxygen partial pressure within the vacuum chamber to be measured and controlled, theoretically in the range from 10-36 to 100 bar. The oxygen control system installed in the ESL laboratory's main chamber consists of an oxygen sensor, oxygen pump, and a control unit. The sensor is a potentiometric device that determines the difference in oxygen activity in two gas compartments (inside the chamber and the air outside of the chamber) separated by an electrolyte, which is yttria-stabilized zirconia. The pump utilizes coulometric titration to either add or remove oxygen. The system is controlled by a desktop control unit, which can also be accessed via a computer. The controller performs temperature control for the sensor and pump, PID-based current loop, and a control algorithm. Oxygen partial pressure has been shown to play a significant role in the surface tension of liquid metals. Oxide films or dissolved oxygen may lead to significant changes in surface tension. The effects of oxygen partial pressure on the surface tension of undercooled liquid nickel will be analyzed, and the results will be presented. The surface tension will be measured at several different oxygen partial pressures while the sample is undercooled. Surface tension will be measured using the oscillating drop method. While undercooled, each sample will be oscillated several times consecutively to investigate how the surface tension behaves with time while at a particular oxygen partial pressure.
Lytle, Jamie; Mwatha, Catherine; Davis, Karen K
2014-01-01
Sleep deprivation in hospitalized patients is common and can have serious detrimental effects on recovery from illness. Lavender aromatherapy has improved sleep in a variety of clinical settings, but the effect has not been tested in the intermediate care unit. To determine the effect of inhalation of 100% lavender oil on patients' vital signs and perceived quality of sleep in an intermediate care unit. A randomized controlled pilot study was conducted in 50 patients. Control patients received usual care. The treatment group had 3 mL of 100% pure lavender oil in a glass jar in place at the bedside from 10 pm until 6 am. Vital signs were recorded at intervals throughout the night. At 6 am all patients completed the Richard Campbell Sleep Questionnaire to assess quality of sleep. Blood pressure was significantly lower between midnight and 4 am in the treatment group than in the control group (P = .03) According to the overall mean change score in blood pressure between the baseline and 6 am measurements, the treatment group had a decrease in blood pressure and the control group had an increase; however, the difference between the 2 groups was not significant (P = .12). Mean overall sleep score was higher in the intervention group (48.25) than in the control group (40.10), but the difference was not significant. Lavender aromatherapy may be an effective way to improve sleep in an intermediate care unit.
Whole-body vibration therapy in intensive care patients: A feasibility and safety study.
Boeselt, Tobias; Nell, Christoph; Kehr, Katahrina; Holland, Angélique; Dresel, Marc; Greulich, Timm; Tackenberg, Björn; Kenn, Klaus; Boeder, Johannes; Klapdor, Benjamin; Kirschbaum, Andreas; Vogelmeier, Claus; Alter, Peter; Koczulla, Andreas Rembert
2016-03-01
Admission to the intensive care unit is associated with sustained loss of muscle mass, reduced quality of life and increased mortality. Early rehabilitation measures may counteract this process. New approaches to rehabilitation while the patient remains in bed are whole-body vibration alone and whole-body vibration with a dumbbell. The aims of this study are to determine the safety of whole-body vibration for patients admitted to the intensive care unit, and to compare the effects of these techniques in intensive care unit patients and healthy subjects. Twelve intensive care unit patients and 12 healthy subjects using whole-body vibration for the first time were examined while lying in bed. First both groups performed whole body vibration over 3 min. In a second step whole body vibration with dumbbell was performed. In order to determine the safety of the training intensity, heart rate, oxygen saturation and blood pressure were measured. The study was approved by the Marburg ethics committee. There were minor reversible and transient increases in diastolic blood pressure (p = 0.005) and heart rate (p = 0.001) in the control group with whole-body vibration with a dumbbell. In intensive care patients receiving whole-body vibration alone, there were increases in diastolic blood pressure (p = 0.011) and heart rate (p < 0.001). This study demonstrates the feasibility of using whole-body vibration and whole-body vibration with a dumbbell for intensive care unit in-bed patients. No clinically significant safety problems were found. Whole-body vibration and whole-body vibration with a dumbbell might therefore be alternative methods for use in early in-bed rehabilitation, not only for hospitalized patients.
Cooper, Richard S; Forrester, Terrence E; Plange-Rhule, Jacob; Bovet, Pascal; Lambert, Estelle V; Dugas, Lara R; Cargill, Kathryn E; Durazo-Arvizu, Ramon A; Shoham, David A; Tong, Liping; Cao, Guichan; Luke, Amy
2015-03-01
Blood pressures in persons of African descent exceed those of other racial/ethnic groups in the United States. Whether this trait is attributable to the genetic factors in African-origin populations, or a result of inadequately measured environmental exposures, such as racial discrimination, is not known. To study this question, we conducted a multisite comparative study of communities in the African diaspora, drawn from metropolitan Chicago, Kingston, Jamaica, rural Ghana, Cape Town, South Africa, and the Seychelles. At each site, 500 participants between the age of 25 and 49 years, with approximately equal sex balance, were enrolled for a longitudinal study of energy expenditure and weight gain. In this study, we describe the patterns of blood pressure and hypertension observed at baseline among the sites. Mean SBP and DBP were very similar in the United States and South Africa in both men and women, although among women, the prevalence of hypertension was higher in the United States (24 vs. 17%, respectively). After adjustment for multiple covariates, relative to participants in the United States, SBP was significantly higher among the South Africans by 9.7 mmHg (P < 0.05) and significantly lower for each of the other sites: for example, Jamaica: -7.9 mmHg (P = 0.06), Ghana: -12.8 mmHg (P < 0.01) and Seychelles: -11.1 mmHg (P = 0.01). These data are consistent with prior findings of a blood pressure gradient in societies of the African diaspora and confirm that African-origin populations with lower social status in multiracial societies, such as the United States and South Africa, experience more hypertension than anticipated based on anthropometric and measurable socioeconomic risk factors.
ORION - Crew Module Side Hatch: Proof Pressure Test Anomaly Investigation
NASA Technical Reports Server (NTRS)
Evernden, Brent A.; Guzman, Oscar J.
2018-01-01
The Orion Multi-Purpose Crew Vehicle program was performing a proof pressure test on an engineering development unit (EDU) of the Orion Crew Module Side Hatch (CMSH) assembly. The purpose of the proof test was to demonstrate structural capability, with margin, at 1.5 times the maximum design pressure, before integrating the CMSH to the Orion Crew Module structural test article for subsequent pressure testing. The pressure test was performed at lower pressures of 3 psig, 10 psig and 15.75 psig with no apparent abnormal behavior or leaking. During pressurization to proof pressure of 23.32 psig, a loud 'pop' was heard at 21.3 psig. Upon review into the test cell, it was noted that the hatch had prematurely separated from the proof test fixture, thus immediately ending the test. The proof pressure test was expected be a simple verification but has since evolved into a significant joint failure investigation from both Lockheed Martin and NASA.
Control rod drive hydraulic system
Ose, Richard A.
1992-01-01
A hydraulic system for a control rod drive (CRD) includes a variable output-pressure CR pump operable in a charging mode for providing pressurized fluid at a charging pressure, and in a normal mode for providing the pressurized fluid at a purge pressure, less than the charging pressure. Charging and purge lines are disposed in parallel flow between the CRD pump and the CRD. A hydraulic control unit is disposed in flow communication in the charging line and includes a scram accumulator. An isolation valve is provided in the charging line between the CRD pump and the scram accumulator. A controller is operatively connected to the CRD pump and the isolation valve and is effective for opening the isolation valve and operating the CRD pump in a charging mode for charging the scram accumulator, and closing the isolation valve and operating the CRD pump in a normal mode for providing to the CRD through the purge line the pressurized fluid at a purge pressure lower than the charging pressure.
Iran: Politics, Human Rights, and U.S. Policy
2017-02-17
Revolution in Iran in 1979, the United States and Iran have been at odds politically and diplomatically, and U.S. policy has been intended to reduce the...the potential for Iran to develop a nuclear weapon increased. Beginning in 2010, the United States orchestrated broad international economic pressure...characterized Iran as an adversary of the United States and stated a commitment to countering Iran’s regional influence – although without taking steps that
Mechanical Extraction of Power From Ocean Currents and Tides
NASA Technical Reports Server (NTRS)
Jones, Jack; Chao, Yi
2010-01-01
A proposed scheme for generating electric power from rivers and from ocean currents, tides, and waves is intended to offer economic and environmental advantages over prior such schemes, some of which are at various stages of implementation, others of which have not yet advanced beyond the concept stage. This scheme would be less environmentally objectionable than are prior schemes that involve the use of dams to block rivers and tidal flows. This scheme would also not entail the high maintenance costs of other proposed schemes that call for submerged electric generators and cables, which would be subject to degradation by marine growth and corrosion. A basic power-generation system according to the scheme now proposed would not include any submerged electrical equipment. The submerged portion of the system would include an all-mechanical turbine/pump unit that would superficially resemble a large land-based wind turbine (see figure). The turbine axis would turn slowly as it captured energy from the local river flow, ocean current, tidal flow, or flow from an ocean-wave device. The turbine axis would drive a pump through a gearbox to generate an enclosed flow of water, hydraulic fluid, or other suitable fluid at a relatively high pressure [typically approx.500 psi (approx.3.4 MPa)]. The pressurized fluid could be piped to an onshore or offshore facility, above the ocean surface, where it would be used to drive a turbine that, in turn, would drive an electric generator. The fluid could be recirculated between the submerged unit and the power-generation facility in a closed flow system; alternatively, if the fluid were seawater, it could be taken in from the ocean at the submerged turbine/pump unit and discharged back into the ocean from the power-generation facility. Another alternative would be to use the pressurized flow to charge an elevated reservoir or other pumped-storage facility, from whence fluid could later be released to drive a turbine/generator unit at a time of high power demand. Multiple submerged turbine/pump units could be positioned across a channel to extract more power than could be extracted by a single unit. In that case, the pressurized flows in their output pipes would be combined, via check valves, into a wider pipe that would deliver the combined flow to a power-generating or pumped-storage facility.
Diagnostic and Treatment Innovations for Mass Casualties
2016-08-01
measurement * U.S. Customary Units Multiply by International Units Divide by † Length/ Area /Volume inch (in) 2.54 × 10 –2 meter (m) foot...cal) (thermochemical) 4.184 joule (J) Pressure atmosphere (atm) 1.013 250 × 10 5 pascal (Pa) pound force per square inch (psi) 6.984 757 × 10
Smoking and Health. A Guide for School Action Grades 1-12.
ERIC Educational Resources Information Center
Ohio State Dept. of Health, Columbus.
Enabling teachers to present a detailed unit on smoking is an objective of this curriculum guide. It organizes information which, if made a relevant part of the student's experience, attempts to help him effectively resist the pressures to begin smoking. Seventeen units, arranged in sequential order, cover cardiovascular and respiratory systems,…
Water Pressure. Water in Africa.
ERIC Educational Resources Information Center
Garrett, Carly Sporer
The Water in Africa Project was realized over a 2-year period by a team of Peace Corps volunteers. As part of an expanded, detailed design, resources were collected from over 90 volunteers serving in African countries, photos and stories were prepared, and standards-based learning units were created for K-12 students. This unit, "Water…
Organisational Culture and Values and the Adaptation of Academic Units in Australian Universities
ERIC Educational Resources Information Center
de Zilwa, Deanna
2007-01-01
This study explores connections between the organisational culture and values of academic units in Australian universities and their efforts to adapt to external environmental pressures. It integrates empirical findings from case studies with theories of organisational culture and values and adaptation. It identifies seven dimensions of academic…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-22
... nuclear power plants, but noted that the Commission's regulations provide mechanisms for individual.... Borchardt (NRC) to M. S. Fertel (Nuclear Energy Institute) dated June 4, 2009. The licensee's request for an... effect. The facility consists of two pressurized-water reactors located in San Diego County, California...
40 CFR 60.5430 - What definitions apply to this subpart?
Code of Federal Regulations, 2013 CFR
2013-07-01
... natural gas liquids from field gas, the fractionation of the liquids into natural gas products, or other... gas unit means a unit used to cool natural gas to the point at which it is condensed into a liquid... pressurized natural gas. Natural gas liquids means the hydrocarbons, such as ethane, propane, butane, and...
NASA Technical Reports Server (NTRS)
Hall, William A.; Gilbert, John
1990-01-01
Electronic metronome paces users through wide range of exercise routines. Conceptual programmable cadence timer provides rhythmic aural and visual cues. Timer automatically changes cadence according to program entered by the user. It also functions as clock, stopwatch, or alarm. Modular pacer operated as single unit or as two units. With audiovisual module moved away from base module, user concentrates on exercise cues without distraction from information appearing on the liquid-crystal display. Variety of uses in rehabilitative medicine, experimental medicine, sports, and gymnastics. Used in intermittent positive-pressure breathing treatment, in which patient must rhythmically inhale and retain medication delivered under positive pressure; and in incentive spirometer treatment, in which patient must inhale maximally at regular intervals.
Fluidized bed coal combustion reactor
NASA Technical Reports Server (NTRS)
Moynihan, P. I.; Young, D. L. (Inventor)
1981-01-01
A fluidized bed coal reactor includes a combination nozzle-injector ash-removal unit formed by a grid of closely spaced open channels, each containing a worm screw conveyor, which function as continuous ash removal troughs. A pressurized air-coal mixture is introduced below the unit and is injected through the elongated nozzles formed by the spaces between the channels. The ash build-up in the troughs protects the worm screw conveyors as does the cooling action of the injected mixture. The ash layer and the pressure from the injectors support a fluidized flame combustion zone above the grid which heats water in boiler tubes disposed within and/or above the combustion zone and/or within the walls of the reactor.
Automatic inspection system for nuclear fuel pellets or rods
Miller, Jr., William H.; Sease, John D.; Hamel, William R.; Bradley, Ronnie A.
1978-01-01
An automatic inspection system is provided for determining surface defects on cylindrical objects such as nuclear fuel pellets or rods. The active element of the system is a compound ring having a plurality of pneumatic jet units directed into a central bore. These jet units are connected to provide multiple circuits, each circuit being provided with a pressure sensor. The outputs of the sensors are fed to a comparator circuit whereby a signal is generated when the difference of pressure between pneumatic circuits, caused by a defect, exceeds a pre-set amount. This signal may be used to divert the piece being inspected into a "reject" storage bin or the like.
Pressure-induced amorphization of charge ordered spinel AlV{sub 2}O{sub 4} at low temperature
DOE Office of Scientific and Technical Information (OSTI.GOV)
Malavi, Pallavi S., E-mail: malavips@barc.gov.in; Karmakar, S., E-mail: malavips@barc.gov.in; Sharma, S. M.
2014-04-24
Structural properties of charge ordered spinel AlV{sub 2}O{sub 4} have been investigated under high pressure at low temperature (80K) by synchrotron based x-ray diffraction measurements. It is observed that upon increasing pressure the structure becomes progressively disordered due to the distortion of the AlO{sub 4} tetrahedral unit and undergoes amorphization above ∼12 GPa. While releasing pressure, the rhombohedral phase is only partially recovered at a much lower pressure (below 5 GPa). Within the stability of the rhombohedral phase, the distortion in the vanadium heptamer increases monotonically with pressure, suggesting enhanced charge ordering. This result is in sharp contrast with themore » recent observation of pressure-induced frustration in the charge ordered state leading to structural transition to the cubic phase at room temperature [JPCM 25, 292201, 2013].« less
Chronically Implanted Pressure Sensors: Challenges and State of the Field
Yu, Lawrence; Kim, Brian J.; Meng, Ellis
2014-01-01
Several conditions and diseases are linked to the elevation or depression of internal pressures from a healthy, normal range, motivating the need for chronic implantable pressure sensors. A simple implantable pressure transduction system consists of a pressure-sensing element with a method to transmit the data to an external unit. The biological environment presents a host of engineering issues that must be considered for long term monitoring. Therefore, the design of such systems must carefully consider interactions between the implanted system and the body, including biocompatibility, surgical placement, and patient comfort. Here we review research developments on implantable sensors for chronic pressure monitoring within the body, focusing on general design requirements for implantable pressure sensors as well as specifications for different medical applications. We also discuss recent efforts to address biocompatibility, efficient telemetry, and drift management, and explore emerging trends. PMID:25365461
NASA Astrophysics Data System (ADS)
Wang, Z. P.; Fang, Q. H.; Li, J.; Liu, B.
2018-04-01
Structural, mechanical and electronic properties of βTiNb alloy under high pressure have been investigated based on the density functional theory (DFT). The dependences of dimensionless volume ratio, elastic constants, bulk modulus, Young's modulus, shear modulus, ductile/brittle, anisotropy and Poisson's ratio on applied pressure are all calculated successfully. The results reveal that βTiNb alloy is mechanically stable under pressure below 23.45 GPa, and the pressure-induced phase transformation could occur beyond this critical value. Meanwhile, the applied pressure can effectively promote the mechanical properties of βTiNb alloy, including the resistances to volume change, elastic deformation and shear deformation, as well as the material ductility and metallicity. Furthermore, the calculated electronic structures testify that βTiNb alloy performs the metallicity and the higher pressure reduces the structural stability of unit cell.
Systems and methods for detection of blowout precursors in combustors
Lieuwen, Tim C.; Nair, Suraj
2006-08-15
The present invention comprises systems and methods for detecting flame blowout precursors in combustors. The blowout precursor detection system comprises a combustor, a pressure measuring device, and blowout precursor detection unit. A combustion controller may also be used to control combustor parameters. The methods of the present invention comprise receiving pressure data measured by an acoustic pressure measuring device, performing one or a combination of spectral analysis, statistical analysis, and wavelet analysis on received pressure data, and determining the existence of a blowout precursor based on such analyses. The spectral analysis, statistical analysis, and wavelet analysis further comprise their respective sub-methods to determine the existence of blowout precursors.
A microprocessor controlled pressure scanning system
NASA Technical Reports Server (NTRS)
Anderson, R. C.
1976-01-01
A microprocessor-based controller and data logger for pressure scanning systems is described. The microcomputer positions and manages data from as many as four 48-port electro-mechanical pressure scanners. The maximum scanning rate is 80 pressure measurements per second (20 ports per second on each of four scanners). The system features on-line calibration, position-directed data storage, and once-per-scan display in engineering units of data from a selected port. The system is designed to be interfaced to a facility computer through a shared memory. System hardware and software are described. Factors affecting measurement error in this type of system are also discussed.
Portable digital pressure indicator for calibrating magnetic tape recorders
NASA Technical Reports Server (NTRS)
Mccormick, Royce F.; Leighty, Bradley D.
1989-01-01
The design of a portable Digital Pressure Indicator (DPI) to be used for calibrating the pressure systems on Langley's magnetic tape recorders is described. High-speed magnetic tape recorders require pressure (0 to 20 psig) for providing an air cushion across the tape guides and a slight vacuum (30 inch H2O) for maintaining the proper number of tape loops in the advance and feed chamber. The DPI is a hand-held device that can be quickly coupled to a magnetic tape recorder and includes a two-position switch for selecting either measured pressure or vacuum, to be displayed digitally in engineering units (psig or inches H2O). The DPI is currently in use in Langley's Analysis and Computation Division.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carlos-Pinedo, C.; Rodríguez-Vargas, I.; Martínez-Orozco, J. C.
In this work we present the results obtained from the calculation of the level structure of a n-type delta-doped well Field Effect Transistor when is subjected to hydrostatic pressure. We study the energy level structure as a function of hydrostatic pressure within the range of 0 to 6 kbar for different Schottky barrier height (SBH). We use an analytical expression for the effect of hydrostatic pressure on the SBH and the pressure dependence of the basic parameters of the system as the effective mass m(P) and the dielectric constant ε(P) of GaAs. We found that due to the effects ofmore » hydrostatic pressure, in addition to electronic level structure alteration, the profile of the differential capacitance per unit area C{sup −2} is affected.« less
Geographically distributed environmental sensor system
French, Patrick; Veatch, Brad; O'Connor, Mike
2006-10-03
The present invention is directed to a sensor network that includes a number of sensor units and a base unit. The base station operates in a network discovery mode (in which network topology information is collected) in a data polling mode (in which sensed information is collected from selected sensory units). Each of the sensor units can include a number of features, including an anemometer, a rain gauge, a compass, a GPS receiver, a barometric pressure sensor, an air temperature sensor, a humidity sensor, a level, and a radiant temperature sensor.
Patient participation in pressure injury prevention: giving patient's a voice.
Latimer, Sharon; Chaboyer, Wendy; Gillespie, Brigid
2014-12-01
Pressure injuries burden patients and healthcare organisations, with some preventative practices having little impact on prevalence reduction. Patient participation in care may be an effective pressure injury prevention strategy, yet patient preferences are unknown. The aim of this interpretive study was to describe patients' perceptions of their current and future role in pressure injury prevention. Semi-structured interviews were conducted with 20 adult inpatients recruited from four medical units, at two Australian metropolitan hospitals. Interview data were analysed using content analysis, with three categories emerging: 'experiencing pressure injuries'; 'participating in pressure injury prevention'; and 'resourcing pressure injury prevention and treatment'. These categories reflect the complex nature of participants' pressure injury experience. The findings suggest participants gather pressure injury knowledge from first-hand and vicarious experience; knowledge they bring to hospital. Most participants preferred a proactive pressure injury prevention role. Many identified barriers in the healthcare environment that impeded their participation and affected their experience of pressure injuries and pressure injury prevention. If patient participation as a pressure injury prevention strategy is to be considered, nurses and organisations need to view patients as partners. © 2013 Nordic College of Caring Science.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-03
... pressurized-water reactors located in Maricopa County, Arizona. 2.0 Request/Action Title 10 of the Code of... in CE NPSD-683-A, Revision 6, for the calculation of flaw stress intensity factors due to membrane stress from pressure loading (K IM ), an exemption was required, since the methodology for the...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-25
... the use of fiber reinforced polymer on masonry walls for uniform pressure loads resulting from a... fail as a result of damage caused by natural phenomena. The in-fill masonry walls to be strengthened... system on existing Auxiliary Building masonry walls will allow them to resist uniform pressure loads...
Code of Federal Regulations, 2014 CFR
2014-10-01
... properly marked valve; and (iv) A UN pressure receptacle is marked with “USA” as a country of approval in...) manufactured to other than a DOT specification or a UN standard in accordance with part 178 of this subchapter.... (2) Cylinders (including UN pressure receptacles) transported to, from, or within the United States...