DOE Office of Scientific and Technical Information (OSTI.GOV)
Qu, H; Yu, N; Qi, P
Purpose: In commercial secondary dose calculation system, an average effective depth is used to calculate the Monitor Units for an arc beam from the volumetric modulated arc (VMAT) plans. Typically, an arithmetic mean of the effective depths (AMED) of a VMAT arc beam is used, which may result in large MU discrepancy from that of the primary treatment planning system. This study is to demonstrate the use of a dose weighted mean effective depth (DWED) can improve accuracy of MU calculation for the secondary MU verification. Methods: In-house scripts were written in the primary treatment planning system (TPS) to firstmore » convert a VMAT arc beam to a series of static step & shoot beams (every 4 degree). The computed dose and effective depth of each static beam were then used to obtain the dose weighted mean effective depth (DWED) for the VMAT beam. The DWED was used for the secondary MU calculation for VMAT plans. Six lung SBRT VMAT plans, eight head and neck VMAT plans and ten prostate VMAT plans that had > 5% MU deviations (failed MU verification) using the AMED method were recalculated with the DWED. For comparison, same number VMAT plans that had < 5% MU deviations (passed MU verification) using AMED method were also reevaluated with the dose weighted mean effective depth method. Results: For MU verification passed plans, the mean and standard deviation of MU differences between the TPS and the secondary calculation program were 2.2%±1.5% for the AMED and 2.1%±1.7% for the DMED method. For the failed plans, the mean and standard deviation of MU differences of TPS to the secondary calculation program were 9.9%±4.7% and 4.7%±2.6, respectively. Conclusion: The dose weighted mean effective depth improved MU calculation accuracy which can be used for the pre-treatment MU verification of VMAT plans.« less
Independent calculation of monitor units for VMAT and SPORT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Xin; Bush, Karl; Ding, Aiping
Purpose: Dose and monitor units (MUs) represent two important facets of a radiation therapy treatment. In current practice, verification of a treatment plan is commonly done in dose domain, in which a phantom measurement or forward dose calculation is performed to examine the dosimetric accuracy and the MU settings of a given treatment plan. While it is desirable to verify directly the MU settings, a computational framework for obtaining the MU values from a known dose distribution has yet to be developed. This work presents a strategy to calculate independently the MUs from a given dose distribution of volumetric modulatedmore » arc therapy (VMAT) and station parameter optimized radiation therapy (SPORT). Methods: The dose at a point can be expressed as a sum of contributions from all the station points (or control points). This relationship forms the basis of the proposed MU verification technique. To proceed, the authors first obtain the matrix elements which characterize the dosimetric contribution of the involved station points by computing the doses at a series of voxels, typically on the prescription surface of the VMAT/SPORT treatment plan, with unit MU setting for all the station points. An in-house Monte Carlo (MC) software is used for the dose matrix calculation. The MUs of the station points are then derived by minimizing the least-squares difference between doses computed by the treatment planning system (TPS) and that of the MC for the selected set of voxels on the prescription surface. The technique is applied to 16 clinical cases with a variety of energies, disease sites, and TPS dose calculation algorithms. Results: For all plans except the lung cases with large tissue density inhomogeneity, the independently computed MUs agree with that of TPS to within 2.7% for all the station points. In the dose domain, no significant difference between the MC and Eclipse Anisotropic Analytical Algorithm (AAA) dose distribution is found in terms of isodose contours, dose profiles, gamma index, and dose volume histogram (DVH) for these cases. For the lung cases, the MC-calculated MUs differ significantly from that of the treatment plan computed using AAA. However, the discrepancies are reduced to within 3% when the TPS dose calculation algorithm is switched to a transport equation-based technique (Acuros™). Comparison in the dose domain between the MC and Eclipse AAA/Acuros calculation yields conclusion consistent with the MU calculation. Conclusions: A computational framework relating the MU and dose domains has been established. The framework does not only enable them to verify the MU values of the involved station points of a VMAT plan directly in the MU domain but also provide a much needed mechanism to adaptively modify the MU values of the station points in accordance to a specific change in the dose domain.« less
Richmond, Neil; Tulip, Rachael; Walker, Chris
2016-01-01
The aim of this work was to determine, by measurement and independent monitor unit (MU) check, the optimum method for determining collimator scatter for an Elekta Synergy linac with an Agility multileaf collimator (MLC) within Radcalc, a commercial MU calculation software package. The collimator scatter factors were measured for 13 field shapes defined by an Elekta Agility MLC on a Synergy linac with 6MV photons. The value of the collimator scatter associated with each field was also calculated according to the equation Sc=Sc(mlc)+Sc(corr)(Sc(open)-Sc(mlc)) with Sc(corr) varied between 0 and 1, where Sc(open) is the value of collimator scatter calculated from the rectangular collimator-defined field and Sc(mlc) the value using only the MLC-defined field shape by applying sector integration. From this the optimum value of the correction was determined as that which gives the minimum difference between measured and calculated Sc. Single (simple fluence modulation) and dual-arc (complex fluence modulation) treatment plans were generated on the Monaco system for prostate volumetric modulated-arc therapy (VMAT) delivery. The planned MUs were verified by absolute dose measurement in phantom and by an independent MU calculation. The MU calculations were repeated with values of Sc(corr) between 0 and 1. The values of the correction yielding the minimum MU difference between treatment planning system (TPS) and check MU were established. The empirically derived value of Sc(corr) giving the best fit to the measured collimator scatter factors was 0.49. This figure however was not found to be optimal for either the single- or dual-arc prostate VMAT plans, which required 0.80 and 0.34, respectively, to minimize the differences between the TPS and independent-check MU. Point dose measurement of the VMAT plans demonstrated that the TPS MUs were appropriate for the delivered dose. Although the value of Sc(corr) may be obtained by direct comparison of calculation with measurement, the efficacy of the value determined for VMAT-MU calculations are very much dependent on the complexity of the MLC delivery. Copyright © 2016 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
Enhanced dynamic wedge and independent monitor unit verification.
Howlett, S J
2005-03-01
Some serious radiation accidents have occurred around the world during the delivery of radiotherapy treatment. The regrettable incident in Panama clearly indicated the need for independent monitor unit (MU) verification. Indeed the International Atomic Energy Agency (IAEA), after investigating the incident, made specific recommendations for radiotherapy centres which included an independent monitor unit check for all treatments. Independent monitor unit verification is practiced in many radiotherapy centres in developed countries around the world. It is mandatory in USA but not yet in Australia. This paper describes development of an independent MU program, concentrating on the implementation of the Enhanced Dynamic Wedge (EDW) component. The difficult case of non centre of field (COF) calculation points under the EDW was studied in some detail. Results of a survey of Australasian centres regarding the use of independent MU check systems is also presented. The system was developed with reference to MU calculations made by Pinnacle 3D Radiotherapy Treatment Planning (RTP) system (ADAC - Philips) for 4MV, 6MV and 18MV X-ray beams used at the Newcastle Mater Misericordiae Hospital (NMMH) in the clinical environment. A small systematic error was detected in the equation used for the EDW calculations. Results indicate that COF equations may be used in the non COF situation with similar accuracy to that achieved with profile corrected methods. Further collaborative work with other centres is planned to extend these findings.
Synchronization of low- and high-threshold motor units.
Defreitas, Jason M; Beck, Travis W; Ye, Xin; Stock, Matt S
2014-04-01
We examined the degree of synchronization for both low- and high-threshold motor unit (MU) pairs at high force levels. MU spike trains were recorded from the quadriceps during high-force isometric leg extensions. Short-term synchronization (between -6 and 6 ms) was calculated for every unique MU pair for each contraction. At high force levels, earlier recruited motor unit pairs (low-threshold) demonstrated relatively low levels of short-term synchronization (approximately 7.3% extra firings than would have been expected by chance). However, the magnitude of synchronization increased significantly and linearly with mean recruitment threshold (reaching 22.1% extra firings for motor unit pairs recruited above 70% MVC). Three potential mechanisms that could explain the observed differences in synchronization across motor unit types are proposed and discussed. Copyright © 2013 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harston, M.R.; Hara, S.; Kino, Y.
1997-10-01
The energy shift due to the finite size of the pseudonucleus (dd{mu}){sub 11}{sup +} in the molecules (dd{mu}){sub 11}e and (dd{mu}){sub 11}dee, the subscripts indicating the first excited state with total angular momentum of one unit, is of importance in the theoretical estimation of the rate of d-d fusion catalyzed by negative muons. The energy shift in the molecule (dd{mu}){sub 11}e is calculated using perturbation theory up to second order. The finite-size shift is found to be 1.46 meV. This is significantly larger than the value of 0.7 meV for this energy shift calculated by Bakalov [Muon Catalyzed Fusion {boldmore » 3}, 321 (1988)] by a method similar to the present method; recently found excellent agreement of theory with experimental results for the formation rate of the molecule (dd{mu}){sub 11}dee was based on Bakalov{close_quote}s value with some modifications. The results of a direct calculation of the finite-size energy shifts in (dd{mu}){sub 11}dee using first-order perturbation theory are presented. The contribution from the quadrupole component of the (dd{mu}){sub 11} charge distribution, which is not taken into account in the conventional scaling procedure based on the finite-size energy shifts of (dd{mu}){sub 11}e, is found to be of the order of 1 meV and to depend on the angular-momentum states of (dd{mu}){sub 11}dee. Sources of uncertainty in the current theoretical estimates are also discussed. {copyright} {ital 1997} {ital The American Physical Society}« less
Monitor unit settings for intensity modulated beams delivered using a step-and-shoot approach.
Sharpe, M B; Miller, B M; Yan, D; Wong, J W
2000-12-01
Two linear accelerators have been commissioned for delivering IMRT treatments using a step-and-shoot approach. To assess beam startup stability for 6 and 18 MV x-ray beams, dose delivered per monitor unit (MU), beam flatness, and beam symmetry were measured as a function of the total number of MU delivered at a clinical dose rate of 400 MU per minute. Relative to a 100 MU exposure, the dose delivered per MU by both linear accelerators was found to be within +/-2% for exposures larger than 4 MU. Beam flatness and symmetry also met accepted quality assurance standards for a minimum exposure of 4 MU. We have found that the performance of the two machines under study is well suited to the delivery of step-and-shoot IMRT. A system of dose calculation has also been commissioned for applying head scatter corrections to fields as small as 1x1 cm2. The accuracy and precision of the relative output calculations in water was validated for small fields and fields offset from the axis of collimator rotation. For both 6 and 18 MV x-ray beams, the dose per MU calculated in a water phantom agrees with measured data to within 1% on average, with a maximum deviation of 2.5%. The largest output factor discrepancies were seen when the actual radiation field size deviated from the set field size. The measured output in water can vary by as much 16% for 1x1 cm2 fields, when the measured field size deviates from the set field size by 2 mm. For a 1 mm deviation, this discrepancy was reduced to 8%. Steps should be taken to ensure collimator precision is tightly controlled when using such small fields. If this is not possible, very small fields should not contribute to a significant portion of the treatment, or uncertainties in the collimator position may effect the accuracy of the dose delivered.
Changes in motor unit recruitment strategy during pain alters force direction.
Tucker, Kylie J; Hodges, Paul W
2010-10-01
Motor unit (MU) recruitment is altered (decreased discharge rate and cessation of discharge in some units, and recruitment of new units) in force-matched contractions during pain compared to contractions performed before pain. As MU's within a motoneurone pool have different force direction properties we hypothesised that altered MU recruitment during experimental knee pain would change the force vector (total force (F(T)): amplitude and angle) generated by the quadriceps. Force was produced at two levels during 1 × 60-s and 3 × 10-s isometric contractions of knee extensors, and recorded by two force transducers at right angles. This enabled calculation of both F(E) (extension force) and F(T). MU recruitment was recorded from the medial and lateral vastii with four fine-wire electrodes. Pain was induced by hypertonic saline injection in the infra-patella fat pad. Nine subjects matched F(E) and six subjects also matched both medial and lateral forces (F(T)) before and during pain. Changes in MU discharge pattern (decreased discharge rate (P<0.001), complete cessation of firing, and recruitment of new units) during pain were associated with a ∼5° change in absolute force angle. As force angle changed in both directions (left/right) for individual subjects with pain there was no change in average F(T) amplitude between conditions. When both medial and lateral forces were matched MU discharge rate decreased (P<0.001) with pain, but, fewer units ceased firing or were newly recruited during pain. Change in motoneurone recruitment during pain alters direction of muscle force. This may be a strategy to avoid pain or protect the painful part. Copyright © 2010 European Federation of International Association for the Study of Pain Chapters. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, H; Guerrero, M; Prado, K
Purpose: Building up a TG-71 based electron monitor-unit (MU) calculation protocol usually involves massive measurements. This work investigates a minimum data set of measurements and its calculation accuracy and measurement time. Methods: For 6, 9, 12, 16, and 20 MeV of our Varian Clinac-Series linear accelerators, the complete measurements were performed at different depth using 5 square applicators (6, 10, 15, 20 and 25 cm) with different cutouts (2, 3, 4, 6, 10, 15 and 20 cm up to applicator size) for 5 different SSD’s. For each energy, there were 8 PDD scans and 150 point measurements for applicator factors,more » cutout factors and effective SSDs that were then converted to air-gap factors for SSD 99–110cm. The dependence of each dosimetric quantity on field size and SSD was examined to determine the minimum data set of measurements as a subset of the complete measurements. The “missing” data excluded in the minimum data set were approximated by linear or polynomial fitting functions based on the included data. The total measurement time and the calculated electron MU using the minimum and the complete data sets were compared. Results: The minimum data set includes 4 or 5 PDD’s and 51 to 66 point measurements for each electron energy, and more PDD’s and fewer point measurements are generally needed as energy increases. Using only <50% of complete measurement time, the minimum data set generates acceptable MU calculation results compared to those with the complete data set. The PDD difference is within 1 mm and the calculated MU difference is less than 1.5%. Conclusion: Data set measurement for TG-71 electron MU calculations can be minimized based on the knowledge of how each dosimetric quantity depends on various setup parameters. The suggested minimum data set allows acceptable MU calculation accuracy and shortens measurement time by a few hours.« less
Stern, Robin L; Heaton, Robert; Fraser, Martin W; Goddu, S Murty; Kirby, Thomas H; Lam, Kwok Leung; Molineu, Andrea; Zhu, Timothy C
2011-01-01
The requirement of an independent verification of the monitor units (MU) or time calculated to deliver the prescribed dose to a patient has been a mainstay of radiation oncology quality assurance. The need for and value of such a verification was obvious when calculations were performed by hand using look-up tables, and the verification was achieved by a second person independently repeating the calculation. However, in a modern clinic using CT/MR/PET simulation, computerized 3D treatment planning, heterogeneity corrections, and complex calculation algorithms such as convolution/superposition and Monte Carlo, the purpose of and methodology for the MU verification have come into question. In addition, since the verification is often performed using a simpler geometrical model and calculation algorithm than the primary calculation, exact or almost exact agreement between the two can no longer be expected. Guidelines are needed to help the physicist set clinically reasonable action levels for agreement. This report addresses the following charges of the task group: (1) To re-evaluate the purpose and methods of the "independent second check" for monitor unit calculations for non-IMRT radiation treatment in light of the complexities of modern-day treatment planning. (2) To present recommendations on how to perform verification of monitor unit calculations in a modern clinic. (3) To provide recommendations on establishing action levels for agreement between primary calculations and verification, and to provide guidance in addressing discrepancies outside the action levels. These recommendations are to be used as guidelines only and shall not be interpreted as requirements.
NASA Astrophysics Data System (ADS)
Tatli, Hamza; Yucel, Derya; Yilmaz, Sercan; Fayda, Merdan
2018-02-01
The aim of this study is to develop an algorithm for independent MU/treatment time (TT) verification for non-IMRT treatment plans, as a part of QA program to ensure treatment delivery accuracy. Two radiotherapy delivery units and their treatment planning systems (TPS) were commissioned in Liv Hospital Radiation Medicine Center, Tbilisi, Georgia. Beam data were collected according to vendors' collection guidelines, and AAPM reports recommendations, and processed by Microsoft Excel during in-house algorithm development. The algorithm is designed and optimized for calculating SSD and SAD treatment plans, based on AAPM TG114 dose calculation recommendations, coded and embedded in MS Excel spreadsheet, as a preliminary verification algorithm (VA). Treatment verification plans were created by TPSs based on IAEA TRS 430 recommendations, also calculated by VA, and point measurements were collected by solid water phantom, and compared. Study showed that, in-house VA can be used for non-IMRT plans MU/TT verifications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Randeniya, S; Mirkovic, D; Titt, U
2014-06-01
Purpose: In intensity modulated proton therapy (IMPT), energy dependent, protons per monitor unit (MU) calibration factors are important parameters that determine absolute dose values from energy deposition data obtained from Monte Carlo (MC) simulations. Purpose of this study was to assess the sensitivity of MC-computed absolute dose distributions to the protons/MU calibration factors in IMPT. Methods: A “verification plan” (i.e., treatment beams applied individually to water phantom) of a head and neck patient plan was calculated using MC technique. The patient plan had three beams; one posterior-anterior (PA); two anterior oblique. Dose prescription was 66 Gy in 30 fractions. Ofmore » the total MUs, 58% was delivered in PA beam, 25% and 17% in other two. Energy deposition data obtained from the MC simulation were converted to Gy using energy dependent protons/MU calibrations factors obtained from two methods. First method is based on experimental measurements and MC simulations. Second is based on hand calculations, based on how many ion pairs were produced per proton in the dose monitor and how many ion pairs is equal to 1 MU (vendor recommended method). Dose distributions obtained from method one was compared with those from method two. Results: Average difference of 8% in protons/MU calibration factors between method one and two converted into 27 % difference in absolute dose values for PA beam; although dose distributions preserved the shape of 3D dose distribution qualitatively, they were different quantitatively. For two oblique beams, significant difference in absolute dose was not observed. Conclusion: Results demonstrate that protons/MU calibration factors can have a significant impact on absolute dose values in IMPT depending on the fraction of MUs delivered. When number of MUs increases the effect due to the calibration factors amplify. In determining protons/MU calibration factors, experimental method should be preferred in MC dose calculations. Research supported by National Cancer Institute grant P01CA021239.« less
Gorshkova, Natalya V; Lobanova, Juliya S; Tokmakova, Irina L; Smirnov, Sergey V; Akhverdyan, Valerii Z; Krylov, Alexander A; Mashko, Sergey V
2018-03-01
A dual-component Mu-transposition system was modified for the integration/amplification of genes in Corynebacterium. The system consists of two types of plasmids: (i) a non-replicative integrative plasmid that contains the transposing mini-Mu(LR) unit bracketed by the L/R Mu ends or the mini-Mu(LER) unit, which additionally contains the enhancer element, E, and (ii) an integration helper plasmid that expresses the transposition factor genes for MuA and MuB. Efficient transposition in the C. glutamicum chromosome (≈ 2 × 10 -4 per cell) occurred mainly through the replicative pathway via cointegrate formation followed by possible resolution. Optimizing the E location in the mini-Mu unit significantly increased the efficiency of Mu-driven intramolecular transposition-amplification in C. glutamicum as well as in gram-negative bacteria. The new C. glutamicum genome modification strategy that was developed allows the consequent independent integration/amplification/fixation of target genes at high copy numbers. After integration/amplification of the first mini-Mu(LER) unit in the C. glutamicum chromosome, the E-element, which is bracketed by lox-like sites, is excised by Cre-mediated fashion, thereby fixing the truncated mini-Mu(LR) unit in its position for the subsequent integration/amplification of new mini-Mu(LER) units. This strategy was demonstrated using the genes for the citrine and green fluorescent proteins, yECitrine and yEGFP, respectively.
Gibbons, John P.; Antolak, John A.; Followill, David S.; Huq, M. Saiful; Klein, Eric E.; Lam, Kwok L.; Palta, Jatinder R.; Roback, Donald M.; Reid, Mark; Khan, Faiz M.
2014-01-01
A protocol is presented for the calculation of monitor units (MU) for photon and electron beams, delivered with and without beam modifiers, for constant source-surface distance (SSD) and source-axis distance (SAD) setups. This protocol was written by Task Group 71 of the Therapy Physics Committee of the American Association of Physicists in Medicine (AAPM) and has been formally approved by the AAPM for clinical use. The protocol defines the nomenclature for the dosimetric quantities used in these calculations, along with instructions for their determination and measurement. Calculations are made using the dose per MU under normalization conditions, \\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{upgreek} \\usepackage{mathrsfs} \\setlength{\\oddsidemargin}{-69pt} \\begin{document} }{}$D_0^\\prime $\\end{document}D0′, that is determined for each user's photon and electron beams. For electron beams, the depth of normalization is taken to be the depth of maximum dose along the central axis for the same field incident on a water phantom at the same SSD, where \\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{upgreek} \\usepackage{mathrsfs} \\setlength{\\oddsidemargin}{-69pt} \\begin{document} }{}$D_0^\\prime $\\end{document}D0′ = 1 cGy/MU. For photon beams, this task group recommends that a normalization depth of 10 cm be selected, where an energy-dependent \\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{upgreek} \\usepackage{mathrsfs} \\setlength{\\oddsidemargin}{-69pt} \\begin{document} }{}$D_0^\\prime $\\end{document}D0′ ≤ 1 cGy/MU is required. This recommendation differs from the more common approach of a normalization depth of dm, with \\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{upgreek} \\usepackage{mathrsfs} \\setlength{\\oddsidemargin}{-69pt} \\begin{document} }{}$D_0^\\prime $\\end{document}D0′ = 1 cGy/MU, although both systems are acceptable within the current protocol. For photon beams, the formalism includes the use of blocked fields, physical or dynamic wedges, and (static) multileaf collimation. No formalism is provided for intensity modulated radiation therapy calculations, although some general considerations and a review of current calculation techniques are included. For electron beams, the formalism provides for calculations at the standard and extended SSDs using either an effective SSD or an air-gap correction factor. Example tables and problems are included to illustrate the basic concepts within the presented formalism. PMID:24593704
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lewis, D; Chi, P; Tailor, R
Purpose: To verify the accuracy of total body irradiation (TBI) measurement commissioning data using the treatment planning system (TPS) for a wide range of patient separations. Methods: Our institution conducts TBI treatments with an 18MV photon beam at 380cm extended SSD using an AP/PA technique. Currently, the monitor units (MU) per field for patient treatments are determined using a lookup table generated from TMR measurements in a water phantom (75 × 41 × 30.5 cm3). The dose prescribed to an umbilicus midline point at spine level is determined based on patient separation, dose/ field and dose rate/MU. One-dimensional heterogeneous dosemore » calculations from Pinnacle TPS were validated with thermoluminescent dosimeters (TLD) placed in an average adult anthropomorphic phantom and also in-vivo on four patients with large separations. Subsequently, twelve patients with various separations (17–47cm) were retrospectively analyzed. Computed tomography (CT) scans were acquired in the left and right decubitus positions from vertex to knee. A treatment plan for each patient was generated. The ratio of the lookup table MU to the heterogeneous TPS MU was compared. Results: TLD Measurements in the anthropomorphic phantom and large TBI patients agreed with Pinnacle calculated dose within 2.8% and 2%, respectively. The heterogeneous calculation compared to the lookup table agreed within 8.1% (ratio range: 1.014–1.081). A trend of reduced accuracy was observed when patient separation increases. Conclusion: The TPS dose calculation accuracy was confirmed by TLD measurements, showing that Pinnacle can model the extended SSD dose without commissioning a special beam model for the extended SSD geometry. The difference between the lookup table and TPS calculation potentially comes from lack of scatter during commissioning when compared to extreme patient sizes. The observed trend suggests the need for development of a correction factor between the lookup table and TPS dose calculations.« less
SU-F-T-67: Correction Factors for Monitor Unit Verification of Clinical Electron Beams
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haywood, J
Purpose: Monitor units calculated by electron Monte Carlo treatment planning systems are often higher than TG-71 hand calculations for a majority of patients. Here I’ve calculated tables of geometry and heterogeneity correction factors for correcting electron hand calculations. Method: A flat water phantom with spherical volumes having radii ranging from 3 to 15 cm was created. The spheres were centered with respect to the flat water phantom, and all shapes shared a surface at 100 cm SSD. D{sub max} dose at 100 cm SSD was calculated for each cone and energy on the flat phantom and for the spherical volumesmore » in the absence of the flat phantom. The ratio of dose in the sphere to dose in the flat phantom defined the geometrical correction factor. The heterogeneity factors were then calculated from the unrestricted collisional stopping power for tissues encountered in electron beam treatments. These factors were then used in patient second check calculations. Patient curvature was estimated by the largest sphere that aligns to the patient contour, and appropriate tissue density was read from the physical properties provided by the CT. The resulting MU were compared to those calculated by the treatment planning system and TG-71 hand calculations. Results: The geometry and heterogeneity correction factors range from ∼(0.8–1.0) and ∼(0.9–1.01) respectively for the energies and cones presented. Percent differences for TG-71 hand calculations drop from ∼(3–14)% to ∼(0–2)%. Conclusion: Monitor units calculated with the correction factors typically decrease the percent difference to under actionable levels, < 5%. While these correction factors work for a majority of patients, there are some patient anatomies that do not fit the assumptions made. Using these factors in hand calculations is a first step in bringing the verification monitor units into agreement with the treatment planning system MU.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woodward, S.; Curtis, M.D.; Rheingold, A.L.
1992-06-01
Cp{sub 2}Nb{sub 2}Cl{sub 2}({mu}-Cl{sub 2})(CO){sub 4} reacts with Cp{sub 2}Ni{sub 2}({mu}-SEt){sub 2} to yield paramagnetic CpNbCl{sub 2}({mu}-SEt){sub 2}NiCp: (g) = 2.004, A = 129 G; space group = P2{sub 1}/c,a = 7.466 (1) {Angstrom}, b = 28.427 (5) {Angstrom}, c = 8.620 (2) {Angstrom}, {beta} = 104.81 (1){degree}. CpNb(PhCCPh)({mu}-SPr{sup i}){sub 2}Mo(CO){sub 4} is synthesized by the addition of LiSPr{sup i} to CpNbCl{sub 2}PhCCPh resulting in formation of CpNb(SPr{sup i}){sub 2}(PhCCPh) followed by the reaction of the thiolate complex with Mo(MeCN){sub 3}(CO){sub 3} and CO (1 equiv). The crystal structure for CpNb(PhCCPh)({mu}-SPr{sup i}){sub 2}Mo(CO){sub 4} is reported and EHMO calculations ofmore » the bonding in CpNbCl{sub 2}({mu}-SEt{sub 2})NiCp were discussed. 27 refs., 5 figs., 5 tabs.« less
Herda, T J; Miller, J D; Trevino, M A; Mosier, E M; Gallagher, P M; Fry, A C; Vardiman, J P
2016-04-01
To investigate the change in motor unit (MU) firing rates (FR) at de-recruitment relative to recruitment and the relation to % type I myosin heavy chain isoform content (type I %MHC) of the vastus lateralis (VL) in vivo. Ten subjects performed a 22-s submaximal isometric trapezoid muscle action that included a linearly increasing, steady force at 50% maximal voluntary contraction, and linearly decreasing segments. Surface electromyographic signals were collected from the VL and were decomposed into constituent MU action potentials trains. A tissue sample from the VL was taken to calculate type I %MHC. The y-intercepts and slopes were calculated for the changes (Δ) in FR at de-recruitment (FRDEREC ) relative to FR at recruitment (FRREC ) vs. FRREC relationship for each subject. Correlations were performed between the y-intercepts and slopes with type I %MHC. The majority of MUs had greater FRDEREC than FRREC . The y-intercepts (r = -0.600, P = 0.067) were not significantly correlated, but the slopes (r = -0.793, P = 0.006) were significantly correlated with type I %MHC. The majority of the motoneuron pool had greater FRDEREC than FRREC , however, individuals with higher type I %MHC had a greater propensity to have MUs with FRREC > FRDEREC as indicated by the slope values. Overall, the contractile properties of the muscle (MHC) could partially explain the differences in MU firing rates at de-recruitment relative to recruitment. Thus, suggesting the fatigability of the muscle influences the alterations in MU firing rates from recruitment to de-recruitment. © 2015 Scandinavian Physiological Society. Published by John Wiley & Sons Ltd.
Sterczala, Adam J; Miller, Jonathan D; Trevino, Michael A; Dimmick, Hannah L; Herda, Trent J
2018-02-26
Previous investigations report no changes in motor unit (MU) firing rates during submaximal contractions following resistance training. These investigations did not account for MU recruitment or examine firing rates as a function of recruitment threshold (REC).Therefore, MU recruitment and firing rates in chronically resistance trained (RT) and physically active controls (CON) were examined. Surface electromyography signals were collected from the first dorsal interosseous (FDI) during isometric muscle actions at 40% and 70% maximal voluntary contraction (MVC). For each MU, force at REC, mean firing rate (MFR) during the steady force, and MU action potential amplitude (MUAPAMP) were analyzed. For each individual and contraction, the MFRs were linearly regressed against REC, whereas, exponential models were applied to the MFR vs. MUAPAMP and MUAPAMP vs. REC relationships with the y-intercepts and slopes (linear) and A and B terms (exponential) calculated. For the 40% MVC, the RT group had less negative slopes (p=0.001) and lower y-intercepts (p=0.006) of the MFR vs. REC relationships and lower B terms (p=0.011) of the MUAPAMP vs. REC relationships. There were no differences in either relationship between groups for the 70% MVC. During the 40% MVC, the RT had a smaller range of MFRs and MUAPAMPS in comparison to the CON, likely due to reduced MU recruitment. The RT had lower MFRs and recruitment during the 40% MVC that may indicate a leftward shift in the force-frequency relationship, and thus require less excitation to the motoneuron pool to match the same relative force.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li Heng; Sahoo, Narayan; Poenisch, Falk
Purpose: The purpose of this work was to assess the monitor unit (MU) values and position accuracy of spot scanning proton beams as recorded by the daily treatment logs of the treatment control system, and furthermore establish the feasibility of using the delivered spot positions and MU values to calculate and evaluate delivered doses to patients. Methods: To validate the accuracy of the recorded spot positions, the authors generated and executed a test treatment plan containing nine spot positions, to which the authors delivered ten MU each. The spot positions were measured with radiographic films and Matrixx 2D ion-chambers arraymore » placed at the isocenter plane and compared for displacements from the planned and recorded positions. Treatment logs for 14 patients were then used to determine the spot MU values and position accuracy of the scanning proton beam delivery system. Univariate analysis was used to detect any systematic error or large variation between patients, treatment dates, proton energies, gantry angles, and planned spot positions. The recorded patient spot positions and MU values were then used to replace the spot positions and MU values in the plan, and the treatment planning system was used to calculate the delivered doses to patients. The results were compared with the treatment plan. Results: Within a treatment session, spot positions were reproducible within {+-}0.2 mm. The spot positions measured by film agreed with the planned positions within {+-}1 mm and with the recorded positions within {+-}0.5 mm. The maximum day-to-day variation for any given spot position was within {+-}1 mm. For all 14 patients, with {approx}1 500 000 spots recorded, the total MU accuracy was within 0.1% of the planned MU values, the mean (x, y) spot displacement from the planned value was (-0.03 mm, -0.01 mm), the maximum (x, y) displacement was (1.68 mm, 2.27 mm), and the (x, y) standard deviation was (0.26 mm, 0.42 mm). The maximum dose difference between calculated dose to the patient based on the plan and recorded data was within 2%. Conclusions: The authors have shown that the treatment log file in a spot scanning proton beam delivery system is precise enough to serve as a quality assurance tool to monitor variation in spot position and MU value, as well as the delivered dose uncertainty from the treatment delivery system. The analysis tool developed here could be useful for assessing spot position uncertainty and thus dose uncertainty for any patient receiving spot scanning proton beam therapy.« less
Kuppusamy, Vijayalakshmi; Nagarajan, Vivekanandan; Jeevanandam, Prakash; Murugan, Lavanya
2016-02-01
The study was aimed to compare two different monitor unit (MU) or dose verification software in volumetric modulated arc therapy (VMAT) using modified Clarkson's integration technique for 6 MV photons beams. In-house Excel Spreadsheet based monitor unit verification calculation (MUVC) program and PTW's DIAMOND secondary check software (SCS), version-6 were used as a secondary check to verify the monitor unit (MU) or dose calculated by treatment planning system (TPS). In this study 180 patients were grouped into 61 head and neck, 39 thorax and 80 pelvic sites. Verification plans are created using PTW OCTAVIUS-4D phantom and also measured using 729 detector chamber and array with isocentre as the suitable point of measurement for each field. In the analysis of 154 clinically approved VMAT plans with isocentre at a region above -350 HU, using heterogeneity corrections, In-house Spreadsheet based MUVC program and Diamond SCS showed good agreement TPS. The overall percentage average deviations for all sites were (-0.93% + 1.59%) and (1.37% + 2.72%) for In-house Excel Spreadsheet based MUVC program and Diamond SCS respectively. For 26 clinically approved VMAT plans with isocentre at a region below -350 HU showed higher variations for both In-house Spreadsheet based MUVC program and Diamond SCS. It can be concluded that for patient specific quality assurance (QA), the In-house Excel Spreadsheet based MUVC program and Diamond SCS can be used as a simple and fast accompanying to measurement based verification for plans with isocentre at a region above -350 HU. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Li, Heng; Sahoo, Narayan; Poenisch, Falk; Suzuki, Kazumichi; Li, Yupeng; Li, Xiaoqiang; Zhang, Xiaodong; Lee, Andrew K.; Gillin, Michael T.; Zhu, X. Ronald
2013-01-01
Purpose: The purpose of this work was to assess the monitor unit (MU) values and position accuracy of spot scanning proton beams as recorded by the daily treatment logs of the treatment control system, and furthermore establish the feasibility of using the delivered spot positions and MU values to calculate and evaluate delivered doses to patients. Methods: To validate the accuracy of the recorded spot positions, the authors generated and executed a test treatment plan containing nine spot positions, to which the authors delivered ten MU each. The spot positions were measured with radiographic films and Matrixx 2D ion-chambers array placed at the isocenter plane and compared for displacements from the planned and recorded positions. Treatment logs for 14 patients were then used to determine the spot MU values and position accuracy of the scanning proton beam delivery system. Univariate analysis was used to detect any systematic error or large variation between patients, treatment dates, proton energies, gantry angles, and planned spot positions. The recorded patient spot positions and MU values were then used to replace the spot positions and MU values in the plan, and the treatment planning system was used to calculate the delivered doses to patients. The results were compared with the treatment plan. Results: Within a treatment session, spot positions were reproducible within ±0.2 mm. The spot positions measured by film agreed with the planned positions within ±1 mm and with the recorded positions within ±0.5 mm. The maximum day-to-day variation for any given spot position was within ±1 mm. For all 14 patients, with ∼1 500 000 spots recorded, the total MU accuracy was within 0.1% of the planned MU values, the mean (x, y) spot displacement from the planned value was (−0.03 mm, −0.01 mm), the maximum (x, y) displacement was (1.68 mm, 2.27 mm), and the (x, y) standard deviation was (0.26 mm, 0.42 mm). The maximum dose difference between calculated dose to the patient based on the plan and recorded data was within 2%. Conclusions: The authors have shown that the treatment log file in a spot scanning proton beam delivery system is precise enough to serve as a quality assurance tool to monitor variation in spot position and MU value, as well as the delivered dose uncertainty from the treatment delivery system. The analysis tool developed here could be useful for assessing spot position uncertainty and thus dose uncertainty for any patient receiving spot scanning proton beam therapy. PMID:23387726
Trevino, Michael A; Herda, Trent J; Fry, Andrew C; Gallagher, Philip M; Vardiman, John P; Mosier, Eric M; Miller, Jonathan D
2016-08-01
It is suggested that firing rate characteristics of motor units (MUs) are influenced by the physical properties of the muscle. However, no study has correlated MU firing rates at recruitment, targeted force, or derecruitment with the contractile properties of the muscle in vivo. Twelve participants (age = 20.67 ± 2.35 yr) performed a 40% isometric maximal voluntary contraction of the leg extensors that included linearly increasing, steady force, and decreasing segments. Muscle biopsies were collected with myosin heavy chain (MHC) content quantified, and surface electromyography (EMG) was recorded from the vastus lateralis. The EMG signal was decomposed into the firing events of single MUs. Slopes and y-intercepts were calculated for 1) firing rates at recruitment vs. recruitment threshold, 2) mean firing rates at steady force vs. recruitment threshold, and 3) firing rates at derecruitment vs. derecruitment threshold relationships for each subject. Correlations among type I %MHC isoform content and the slopes and y-intercepts from the three relationships were examined. Type I %MHC isoform content was correlated with MU firing rates at recruitment (y-intercepts: r = -0.577; slopes: r = 0.741) and targeted force (slopes: r = 0.853) vs. recruitment threshold and MU firing rates at derecruitment (y-intercept: r = -0.597; slopes: r = 0.701) vs. derecruitment threshold relationships. However, the majority of the individual MU firing rates vs. recruitment and derecruitment relationships were not significant (P > 0.05) and, thus, revealed no systematic pattern. In contrast, MU firing rates during the steady force demonstrated a systematic pattern with higher firing rates for the lower- than higher-threshold MUs and were correlated with the physical properties of MUs in vivo. Copyright © 2016 the American Physiological Society.
Svendsen, Helle; Overgaard, Jacob; Chevallier, Marie A; Collet, Eric; Chen, Yu-Sheng; Jensen, Frank; Iversen, Bo B
2010-06-25
Single-crystal X-ray diffraction measurements have been carried out on [Nd(dmf)(4)(H(2)O)(3)(mu-CN)Fe(CN)(5)].H(2)O (1; dmf=dimethylformamide), [Nd(dmf)(4)(H(2)O)(3)(mu-CN)Co(CN)(5)].H(2)O (2), [La(dmf)(4)(H(2)O)(3)(mu-CN)Fe(CN)(5)].H(2)O (3), [Gd(dmf)(4)(H(2)O)(3)(mu-CN)Fe(CN)(5)].H(2)O (4), and [Y(dmf)(4)(H(2)O)(3)(mu-CN)Fe(CN)(5)].H(2)O (5), at 15(2) K with and without UV illumination of the crystals. Significant changes in unit-cell parameters were observed for all the iron-containing complexes, whereas 2 showed no response to UV illumination. Photoexcited crystal structures have been determined for 1, 3, and 4 based on refinements of two-conformer models, and excited-state occupancies of 78.6(1), 84(6), and 86.6(7)% were reached, respectively. Significant bond-length changes were observed for the Fe-ligand bonds (up to 0.19 A), the cyano bonds (up to 0.09 A), and the lanthanide-ligand bonds (up to 0.10 A). Ab initio theoretical calculations were carried out for the experimental ground-state geometry of 1 to understand the electronic structure changes upon UV illumination. The calculations suggest that UV illumination gives a charge transfer from the cyano groups on the iron atom to the lanthanide ion moiety, {Nd(dmf)(4)(H(2)O)(3)}, with a distance of approximately 6 A from the iron atom. The charge transfer is accompanied by a reorganization of the spin state on the {Fe(CN)(6)} complex, and a change in geometry that produces a metastable charge-transfer state with an increased number of unpaired electrons, thus accounting for the observed photomagnetic effect.
Herda, Trent J; Cooper, Michael A
2014-08-01
The purpose of the study was to examine motor unit (MU) recruitment and derecruitment thresholds and firing rates of the vastus lateralis between 2 healthy (HE) individuals (women, ages = 19 and 23 years) and 1 individual (man, age = 22 years) who acquired acute poliomyelitis (PO). Each participant performed submaximal isometric trapezoid muscle actions of the leg extensors from 20% to 90% maximal voluntary contraction in 10% increments with a sensor placed on the vastus lateralis to record electromyography. Electromyographic signals were decomposed into the firing events of single MUs. Linear regressions were performed on the firing rates at recruitment and peak firing rates versus the recruitment thresholds and the derecruitment versus recruitment thresholds. In addition, data were pooled together from all contractions to examine differences between PO and HE with independent samples t-tests calculated for firing rates at recruitment, peak firing rates, recruitment thresholds, derecruitment thresholds, and duration of MU activity. The results demonstrated systematic differences in MU control strategies between the PO and HE. There were differences in the recruitment thresholds (P < 0.001; HE = 30.5% ± 22.2% maximal voluntary contraction; PO = 14.5% ± 5.0% maximal voluntary contraction), firing rates at recruitment (P < 0.001; HE = 7.4 ± 2.5 pulses per second; PO = 6.2 ± 1.7 pulses per second) and peak firing rates across the force spectrum (P = 0.001; HE = 22.2 ± 5.8 pulses per second; PO = 20.3 ± 2.3 pulses per second), altered derecruitment versus recruitment relationships (HE slope = 0.82 derec/rec, PO slope = 1.78 derec/rec), and duration of MU activity (P < 0.001) between the PO (18.6 ± 2.4 seconds) and HE (15.3 ± 3.0 seconds). Future research should examine the possible differences in MU behavior between PO and HE as a result of fatigue to further elucidate disease-related changes in MU properties.
Assessment of the Monitor Unit Objective tool for VMAT in the Eclipse treatment planning system.
Jiménez-Puertas, Sara; Sánchez-Artuñedo, David; Hermida-López, Marcelino
2018-01-01
This work aims to achieve the highest possible monitor units (MU) reduction using the MU Objective tool included in the Eclipse treatment planning system, while preserving the plan quality. The treatment planning system Eclipse (Varian Medical Systems, Palo Alto, CA) includes a control mechanism for the number of monitor units of volumetric modulated arc therapy (VMAT) plans, named the MU Objective tool. Forty prostate plans, 20 gynecological plans and 20 head and neck plans designed with VMAT were retrospectively studied. Each plan ( base plan ) was optimized without using the MU Objective tool, and it was re-optimized with different values of the Maximum MU ( MaxMU ) parameter of the MU Objective tool. MU differences were analyzed with a paired samples t -test and changes in plan quality were assessed with a set of parameters for OARs and PTVs. The average relative MU difference [Formula: see text] considering all treatment sites, was the highest when MaxMU = 400 (-4.2%, p < 0.001). For prostate plans, the lowest [Formula: see text] was obtained (-3.7%, p < 0.001). For head and neck plans [Formula: see text] was -7.3% ( p < 0.001) and for gynecological plans [Formula: see text] was 7.0% ( p = 0.002). Although similar MU reductions were observed for both sites, for some gynecological plans maximum differences were greater than 10%. All the assessed parameters for PTVs and OARs sparing showed average differences below 2%. For the three studied clinical sites, establishing MaxMU = 400 led to the optimum MU reduction, maintaining the original dose distribution and dosimetric parameters practically unaltered.
Friedberg-Lee model at finite temperature and density
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mao Hong; CCAST; Yao Minjie
2008-06-15
The Friedberg-Lee model is studied at finite temperature and density. By using the finite temperature field theory, the effective potential of the Friedberg-Lee model and the bag constant B(T) and B(T,{mu}) have been calculated at different temperatures and densities. It is shown that there is a critical temperature T{sub C}{approx_equal}106.6 MeV when {mu}=0 MeV and a critical chemical potential {mu}{approx_equal}223.1 MeV for fixing the temperature at T=50 MeV. We also calculate the soliton solutions of the Friedberg-Lee model at finite temperature and density. It turns out that when T{<=}T{sub C} (or {mu}{<=}{mu}{sub C}), there is a bag constant B(T) [ormore » B(T,{mu})] and the soliton solutions are stable. However, when T>T{sub C} (or {mu}>{mu}{sub C}) the bag constant B(T)=0 MeV [or B(T,{mu})=0 MeV] and there is no soliton solution anymore, therefore, the confinement of quarks disappears quickly.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kazakia,G.; Burghardt, A.; Cheung, S.
2008-01-01
Assessment of bone tissue mineral density (TMD) may provide information critical to the understanding of mineralization processes and bone biomechanics. High-resolution three-dimensional assessment of TMD has recently been demonstrated using synchrotron radiation microcomputed tomography (SR{mu}CT); however, this imaging modality is relatively inaccessible due to the scarcity of SR facilities. Conventional desktop {mu}CT systems are widely available and have been used extensively to assess bone microarchitecture. However, the polychromatic source and cone-shaped beam geometry complicate assessment of TMD by conventional {mu}CT. The goal of this study was to evaluate {mu}CT-based measurement of degree and distribution of tissue mineralization in a quantitative,more » spatially resolved manner. Specifically, {mu}CT measures of bone mineral content (BMC) and TMD were compared to those obtained by SR{mu}CT and gravimetric methods. Cylinders of trabecular bone were machined from human femoral heads (n=5), vertebrae (n=5), and proximal tibiae (n=4). Cylinders were imaged in saline on a polychromatic {mu}CT system at an isotropic voxel size of 8 {mu}m. Volumes were reconstructed using beam hardening correction algorithms based on hydroxyapatite (HA)-resin wedge phantoms of 200 and 1200 mgHA/cm3. SR{mu}CT imaging was performed at an isotropic voxel size of 7.50 {mu}m at the National Synchrotron Light Source. Attenuation values were converted to HA concentration using a linear regression derived by imaging a calibration phantom. Architecture and mineralization parameters were calculated from the image data. Specimens were processed using gravimetric methods to determine ash mass and density. {mu}CT-based BMC values were not affected by altering the beam hardening correction. Volume-averaged TMD values calculated by the two corrections were significantly different (p=0.008) in high volume fraction specimens only, with the 1200 mgHA/cm3 correction resulting in a 4.7% higher TMD value. {mu}CT and SR{mu}CT provided significantly different measurements of both BMC and TMD (p<0.05). In high volume fraction specimens, {mu}CT with 1200 mgHA/cm3 correction resulted in BMC and TMD values 16.7% and 15.0% lower, respectively, than SR{mu}CT values. In low volume fraction specimens, {mu}CT with 1200 mgHA/cm3 correction resulted in BMC and TMD values 12.8% and 12.9% lower, respectively, than SR{mu}CT values. {mu}CT and SR{mu}CT values were well-correlated when volume fraction groups were considered individually (BMC R2=0.97-1.00; TMD R2=0.78-0.99). Ash mass and density were higher than the SR{mu}CT equivalents by 8.6% in high volume fraction specimens and 10.9% in low volume fraction specimens (p<0.05). BMC values calculated by tomography were highly correlated with ash mass (ash versus {mu}CT R2=0.96-1.00; ash versus SR{mu}CT R2=0.99-1.00). TMD values calculated by tomography were moderately correlated with ash density (ash versus {mu}CT R2=0.64-0.72; ash versus SR{mu}CT R2=0.64). Spatially resolved comparisons highlighted substantial geometric nonuniformity in the {mu}CT data, which were reduced (but not eliminated) using the 1200 mg HA/cm3 beam hardening correction, and did not exist in the SR{mu}CT data. This study represents the first quantitative comparison of {mu}CT mineralization evaluation against SR{mu}CT and gravimetry. Our results indicate that {mu}CT mineralization measures are underestimated but well-correlated with SR{mu}CT and gravimetric data, particularly when volume fraction groups are considered individually.« less
Bednarz, Bryan; Hancox, Cindy; Xu, X George
2012-01-01
There is growing concern about radiation-induced second cancers associated with radiation treatments. Particular attention has been focused on the risk to patients treated with intensity-modulated radiation therapy (IMRT) due primarily to increased monitor units. To address this concern we have combined a detailed medical linear accelerator model of the Varian Clinac 2100 C with anatomically realistic computational phantoms to calculate organ doses from selected treatment plans. This paper describes the application to calculate organ-averaged equivalent doses using a computational phantom for three different treatments of prostate cancer: a 4-field box treatment, the same box treatment plus a 6-field 3D-CRT boost treatment and a 7-field IMRT treatment. The equivalent doses per MU to those organs that have shown a predilection for second cancers were compared between the different treatment techniques. In addition, the dependence of photon and neutron equivalent doses on gantry angle and energy was investigated. The results indicate that the box treatment plus 6-field boost delivered the highest intermediate- and low-level photon doses per treatment MU to the patient primarily due to the elevated patient scatter contribution as a result of an increase in integral dose delivered by this treatment. In most organs the contribution of neutron dose to the total equivalent dose for the 3D-CRT treatments was less than the contribution of photon dose, except for the lung, esophagus, thyroid and brain. The total equivalent dose per MU to each organ was calculated by summing the photon and neutron dose contributions. For all organs non-adjacent to the primary beam, the equivalent doses per MU from the IMRT treatment were less than the doses from the 3D-CRT treatments. This is due to the increase in the integral dose and the added neutron dose to these organs from the 18 MV treatments. However, depending on the application technique and optimization used, the required MU values for IMRT treatments can be two to three times greater than 3D CRT. Therefore, the total equivalent dose in most organs would be higher from the IMRT treatment compared to the box treatment and comparable to the organ doses from the box treatment plus the 6-field boost. This is the first time when organ dose data for an adult male patient of the ICRP reference anatomy have been calculated and documented. The tools presented in this paper can be used to estimate the second cancer risk to patients undergoing radiation treatment. PMID:19671968
NASA Astrophysics Data System (ADS)
Bednarz, Bryan; Hancox, Cindy; Xu, X. George
2009-09-01
There is growing concern about radiation-induced second cancers associated with radiation treatments. Particular attention has been focused on the risk to patients treated with intensity-modulated radiation therapy (IMRT) due primarily to increased monitor units. To address this concern we have combined a detailed medical linear accelerator model of the Varian Clinac 2100 C with anatomically realistic computational phantoms to calculate organ doses from selected treatment plans. This paper describes the application to calculate organ-averaged equivalent doses using a computational phantom for three different treatments of prostate cancer: a 4-field box treatment, the same box treatment plus a 6-field 3D-CRT boost treatment and a 7-field IMRT treatment. The equivalent doses per MU to those organs that have shown a predilection for second cancers were compared between the different treatment techniques. In addition, the dependence of photon and neutron equivalent doses on gantry angle and energy was investigated. The results indicate that the box treatment plus 6-field boost delivered the highest intermediate- and low-level photon doses per treatment MU to the patient primarily due to the elevated patient scatter contribution as a result of an increase in integral dose delivered by this treatment. In most organs the contribution of neutron dose to the total equivalent dose for the 3D-CRT treatments was less than the contribution of photon dose, except for the lung, esophagus, thyroid and brain. The total equivalent dose per MU to each organ was calculated by summing the photon and neutron dose contributions. For all organs non-adjacent to the primary beam, the equivalent doses per MU from the IMRT treatment were less than the doses from the 3D-CRT treatments. This is due to the increase in the integral dose and the added neutron dose to these organs from the 18 MV treatments. However, depending on the application technique and optimization used, the required MU values for IMRT treatments can be two to three times greater than 3D CRT. Therefore, the total equivalent dose in most organs would be higher from the IMRT treatment compared to the box treatment and comparable to the organ doses from the box treatment plus the 6-field boost. This is the first time when organ dose data for an adult male patient of the ICRP reference anatomy have been calculated and documented. The tools presented in this paper can be used to estimate the second cancer risk to patients undergoing radiation treatment.
Assessing dose rate distributions in VMAT plans
NASA Astrophysics Data System (ADS)
Mackeprang, P.-H.; Volken, W.; Terribilini, D.; Frauchiger, D.; Zaugg, K.; Aebersold, D. M.; Fix, M. K.; Manser, P.
2016-04-01
Dose rate is an essential factor in radiobiology. As modern radiotherapy delivery techniques such as volumetric modulated arc therapy (VMAT) introduce dynamic modulation of the dose rate, it is important to assess the changes in dose rate. Both the rate of monitor units per minute (MU rate) and collimation are varied over the course of a fraction, leading to different dose rates in every voxel of the calculation volume at any point in time during dose delivery. Given the radiotherapy plan and machine specific limitations, a VMAT treatment plan can be split into arc sectors between Digital Imaging and Communications in Medicine control points (CPs) of constant and known MU rate. By calculating dose distributions in each of these arc sectors independently and multiplying them with the MU rate, the dose rate in every single voxel at every time point during the fraction can be calculated. Independently calculated and then summed dose distributions per arc sector were compared to the whole arc dose calculation for validation. Dose measurements and video analysis were performed to validate the calculated datasets. A clinical head and neck, cranial and liver case were analyzed using the tool developed. Measurement validation of synthetic test cases showed linac agreement to precalculated arc sector times within ±0.4 s and doses ±0.1 MU (one standard deviation). Two methods for the visualization of dose rate datasets were developed: the first method plots a two-dimensional (2D) histogram of the number of voxels receiving a given dose rate over the course of the arc treatment delivery. In similarity to treatment planning system display of dose, the second method displays the dose rate as color wash on top of the corresponding computed tomography image, allowing the user to scroll through the variation over time. Examining clinical cases showed dose rates spread over a continuous spectrum, with mean dose rates hardly exceeding 100 cGy min-1 for conventional fractionation. A tool to analyze dose rate distributions in VMAT plans with sub-second accuracy was successfully developed and validated. Dose rates encountered in clinical VMAT test cases show a continuous spectrum with a mean less than or near 100 cGy min-1 for conventional fractionation.
SU-E-T-551: Monitor Unit Optimization in Stereotactic Body Radiation Therapy for Stage I Lung Cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, B-T; Lu, J-Y
2015-06-15
Purpose: The study aims to reduce the monitor units (MUs) in the stereotactic body radiation therapy (SBRT) treatment for lung cancer by adjusting the optimizing parameters. Methods: Fourteen patients suffered from stage I Non-Small Cell Lung Cancer (NSCLC) were enrolled. Three groups of parameters were adjusted to investigate their effects on MU numbers and organs at risk (OARs) sparing: (1) the upper objective of planning target volume (UOPTV); (2) strength setting in the MU constraining objective; (3) max MU setting in the MU constraining objective. Results: We found that the parameters in the optimizer influenced the MU numbers in amore » priority, strength and max MU dependent manner. MU numbers showed a decreasing trend with the UOPTV increasing. MU numbers with low, medium and high priority for the UOPTV were 428±54, 312±48 and 258±31 MU/Gy, respectively. High priority for UOPTV also spared the heart, cord and lung while maintaining comparable PTV coverage than the low and medium priority group. It was observed that MU numbers tended to decrease with the strength increasing and max MU setting decreasing. With maximum strength, the MU numbers reached its minimum while maintaining comparable or improved dose to the normal tissues. It was also found that the MU numbers continued to decline at 85% and 75% max MU setting but no longer to decrease at 50% and 25%. Combined with high priority for UOPTV and MU constraining objectives, the MU numbers can be decreased as low as 223±26 MU/Gy. Conclusion:: The priority of UOPTV, MU constraining objective in the optimizer impact on the MU numbers in SBRT treatment for lung cancer. Giving high priority to the UOPTV, setting the strength to maximum value and the max MU to 50% in the MU objective achieves the lowest MU numbers while maintaining comparable or improved OAR sparing.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pokhrel, D; Badkul, R; Jiang, H
2014-06-01
Purpose: Lung-SBRT uses hypo-fractionated dose in small non-IMRT fields with tissue-heterogeneity corrected plans. An independent MU verification is mandatory for safe and effective delivery of the treatment plan. This report compares planned MU obtained from iPlan-XVM-Calgorithm against spreadsheet-based hand-calculation using most commonly used simple TMR-based method. Methods: Treatment plans of 15 patients who underwent for MC-based lung-SBRT to 50Gy in 5 fractions for PTV V100%=95% were studied. ITV was delineated on MIP images based on 4D-CT scans. PTVs(ITV+5mm margins) ranged from 10.1- 106.5cc(average=48.6cc). MC-SBRT plans were generated using a combination of non-coplanar conformal arcs/beams using iPlan XVM-Calgorithm (BrainLAB iPlan ver.4.1.2)more » for Novalis-TX consisting of micro-MLCs and 6MV-SRS (1000MU/min) beam. These plans were re-computed using heterogeneity-corrected Pencil-Beam (PB-hete) algorithm without changing any beam parameters, such as MLCs/MUs. Dose-ratio: PB-hete/MC gave beam-by-beam inhomogeneity-correction-factors (ICFs):Individual Correction. For independent-2nd-check, MC-MUs were verified using TMR-based hand-calculation and obtained an average ICF:Average Correction, whereas TMR-based hand-calculation systematically underestimated MC-MUs by ∼5%. Also, first 10 MC-plans were verified with an ion-chamber measurement using homogenous phantom. Results: For both beams/arcs, mean PB-hete dose was systematically overestimated by 5.5±2.6% and mean hand-calculated MU systematic underestimated by 5.5±2.5% compared to XVMC. With individual correction, mean hand-calculated MUs matched with XVMC by - 0.3±1.4%/0.4±1.4 for beams/arcs, respectively. After average 5% correction, hand-calculated MUs matched with XVMC by 0.5±2.5%/0.6±2.0% for beams/arcs, respectively. Smaller dependence on tumor volume(TV)/field size(FS) was also observed. Ion-chamber measurement was within ±3.0%. Conclusion: PB-hete overestimates dose to lung tumor relative to XVMC. XVMC-algorithm is much more-complex and accurate with tissues-heterogeneities. Measurement at machine is time consuming and need extra resources; also direct measurement of dose for heterogeneous treatment plans is not clinically practiced, yet. This simple correction-based method was very helpful for independent-2nd-check of MC-lung-SBRT plans and routinely used in our clinic. A look-up table can be generated to include TV/FS dependence in ICFs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
VanAntwerp, April E.; Raymond, Sarah M., E-mail: raymons9@ccf.org; Addington, Mark C.
2011-10-01
The aim of this study was to evaluate radiation dose for organs at risk (OAR) within the cranium, thorax, and pelvis from megavoltage cone-beam computed tomography (MV-CBCT). Using a clinical treatment planning system, CBCT doses were calculated from 60 patient datasets using 27.4 x 27.4 cm{sup 2} field size and 200{sup o} arc length. The body mass indices (BMIs) for these patients range from 17.2-48.4 kg/m{sup 2}. A total of 60 CBCT plans were created and calculated with heterogeneity corrections, with monitor units (MU) that varied from 8, 4, and 2 MU per plan. The isocenters of these plans weremore » placed at defined anatomical structures. The maximum dose, dose to the isocenter, and mean dose to the selected critical organs were analyzed. The study found that maximum and isocenter doses were weakly associated with BMI, but linearly associated with the total MU. Average maximum/isocenter doses in the cranium were 10.0 ({+-} 0.18)/7.0 ({+-} 0.08) cGy, 5.0 ({+-} 0.09)/3.5 ({+-} 0.05) cGy, and 2.5 ({+-} .04)/1.8 ({+-} 0.05) cGy for 8, 4, and 2 MU, respectively. Similar trends but slightly larger maximum/isocenter doses were found in the thoracic and pelvic regions. For the cranial region, the average mean doses with a total of 8 MU to the eye, lens, and brain were 9.7 ({+-} 0.12) cGy, 9.1 ({+-} 0.16) cGy, and 7.2 ({+-} 0.10) cGy, respectively. For the thoracic region, the average mean doses to the lung, heart, and spinal cord were 6.6 ({+-} 0.05) cGy, 6.9 ({+-} 1.2) cGy, and 4.7 ({+-} 0.8) cGy, respectively. For the pelvic region, the average mean dose to the femoral heads was 6.4 ({+-} 1.1) cGy. The MV-CBCT doses were linearly associated with the total MU but weakly dependent on patients' BMIs. Daily MV-CBCT has a cumulative effect on the total body dose and critical organs, which should be carefully considered for clinical impacts.« less
NASA Astrophysics Data System (ADS)
Chandrasena, L.; McKenzie, I.; Brodovitch, J.-C.; Mozafari, M.; Cottrell, S. P.; Percival, P. W.
2014-12-01
Polyether ether ketone (PEEK) is a thermoplastic polymer with a wide range of applications due to its chemical inertness and thermal stability, and for these reasons sample cells for gas and liquid phase μSR have been constructed from PEEK. Muon levelcrossing resonance (μLCR) studies of PEEK revealed a broad, strong μLCR signal that, we hypothesize, is due to multiple overlapping resonances from the various muonium (Mu) adducts of PEEK. To investigate this, two monomer units from PEEK (4,4'-dihydroxybenzophenone and para-dimethoxybenzene) were studied in solution using transverse-field muon spin rotation (TF-μSR) and μLCR. Two different muoniated radicals were formed by Mu addition to 4,4/- dihydroxybenzophenone and one radical was formed in para-dimethoxybenzene. The μSR spectra were assigned by comparing the experimentally measured muon and proton hyperfine coupling constants with values calculated for the possible structures using Gaussian-09 software with the B3LYP functional and 6-31G basis set. Good agreement was found for cyclohexadienyl- type radicals formed by Mu addition to the benzene rings of the monomer units. We can also infer that these radicals are being formed in PEEK, and based on this we conclude that sample cells made of PEEK are unsuitable for many types of μSR experiment.
Boe, S G; Dalton, B H; Harwood, B; Doherty, T J; Rice, C L
2009-05-01
To establish the inter-rater reliability of decomposition-based quantitative electromyography (DQEMG) derived motor unit number estimates (MUNEs) and quantitative motor unit (MU) analysis. Using DQEMG, two examiners independently obtained a sample of needle and surface-detected motor unit potentials (MUPs) from the tibialis anterior muscle from 10 subjects. Coupled with a maximal M wave, surface-detected MUPs were used to derive a MUNE for each subject and each examiner. Additionally, size-related parameters of the individual MUs were obtained following quantitative MUP analysis. Test-retest MUNE values were similar with high reliability observed between examiners (ICC=0.87). Additionally, MUNE variability from test-retest as quantified by a 95% confidence interval was relatively low (+/-28 MUs). Lastly, quantitative data pertaining to MU size, complexity and firing rate were similar between examiners. MUNEs and quantitative MU data can be obtained with high reliability by two independent examiners using DQEMG. Establishing the inter-rater reliability of MUNEs and quantitative MU analysis using DQEMG is central to the clinical applicability of the technique. In addition to assessing response to treatments over time, multiple clinicians may be involved in the longitudinal assessment of the MU pool of individuals with disorders of the central or peripheral nervous system.
A motor unit-based model of muscle fatigue
2017-01-01
Muscle fatigue is a temporary decline in the force and power capacity of skeletal muscle resulting from muscle activity. Because control of muscle is realized at the level of the motor unit (MU), it seems important to consider the physiological properties of motor units when attempting to understand and predict muscle fatigue. Therefore, we developed a phenomenological model of motor unit fatigue as a tractable means to predict muscle fatigue for a variety of tasks and to illustrate the individual contractile responses of MUs whose collective action determines the trajectory of changes in muscle force capacity during prolonged activity. An existing MU population model was used to simulate MU firing rates and isometric muscle forces and, to that model, we added fatigue-related changes in MU force, contraction time, and firing rate associated with sustained voluntary contractions. The model accurately estimated endurance times for sustained isometric contractions across a wide range of target levels. In addition, simulations were run for situations that have little experimental precedent to demonstrate the potential utility of the model to predict motor unit fatigue for more complicated, real-world applications. Moreover, the model provided insight into the complex orchestration of MU force contributions during fatigue, that would be unattainable with current experimental approaches. PMID:28574981
Harkins, Seth B; Mankad, Neal P; Miller, Alexander J M; Szilagyi, Robert K; Peters, Jonas C
2008-03-19
A series of dicopper diamond core complexes that can be isolated in three different oxidation states ([Cu2(mu-XR2)]n+, where n = 0, 1, 2 and X = N or P) is described. Of particular interest is the relative degree of oxidation of the respective copper centers and the bridging XR2 units, upon successive oxidations. These dicopper complexes feature terminal phosphine and either bridging amido or phosphido donors, and as such their metal-ligand bonds are highly covalent. Cu K-edge, Cu L-edge, and P K-edge spectroscopies, in combination with solid-state X-ray structures and DFT calculations, provides a complementary electronic structure picture for the entire set of complexes that tracks the involvement of a majority of ligand-based redox chemistry. The electronic structure picture that emerges for these inorganic dicopper diamond cores shares similarities with the Cu2(mu-SR)2 CuA sites of cytochrome c oxidases and nitrous oxide reductases.
de Visser, Sam P
2008-01-01
Density functional calculations on a mu-oxo-mu-peroxodiiron complex (1) with a tetrapodal ligand BPP (BPP=N,N-bis(2-pyridylmethyl)-3-aminopropionate) are presented that is a biomimetic of the active site region of ribonucleotide reductase (RNR). We have studied all low-lying electronic states and show that it has close-lying broken-shell singlet and undecaplet (S=0, 5) ground states with essentially two sextet spin iron atoms. In strongly distorted electronic systems in which the two iron atoms have different spin states, the peroxo group moves considerably out of the plane of the mu-oxodiiron group due to orbital rearrangements. The calculated absorption spectra of (1,11)1 are in good agreement with experimental studies on biomimetics and RNR enzyme systems. Moreover, vibrational shifts in the spectrum due to (18)O(2) substitution of the oxygen atoms in the peroxo group follow similar trends as experimental observations. To identify whether the mu-oxo-mu-1,2-peroxodiiron or the mu-oxo-mu-1,1-peroxodiiron complexes are able to epoxidize substrates, we studied the reactivity patterns versus propene. Generally, the reactions are stepwise via radical intermediates and proceed by two-state reactivity patterns on competing singlet and undecaplet spin state surfaces. However, both the mu-oxo-mu-1,2-peroxodiiron and mu-oxo-mu-1,1-peroxodiiron complex are sluggish oxidants with high epoxidation barriers. The epoxidation barriers for the mu-oxo-mu-1,1-peroxodiiron complex are significantly lower than the ones for the mu-oxo-mu-1,2-peroxodiiron complex but still are too high to be considered for catalytic properties. Thus, theory has ruled out two possible peroxodiiron catalysts as oxidants in RNR enzymes and biomimetics and the quest to find the actual oxidant in the enzyme mechanism continues.
Small vertical changes in jaw relation affect motor unit recruitment in the masseter.
Terebesi, S; Giannakopoulos, N N; Brüstle, F; Hellmann, D; Türp, J C; Schindler, H J
2016-04-01
Strategies for recruitment of masseter muscle motor units (MUs), provoked by constant bite force, for different vertical jaw relations have not previously been investigated. The objective of this study was to analyse the effect of small changes in vertical jaw relation on MU recruitment behaviour in different regions of the masseter during feedback-controlled submaximum biting tasks. Twenty healthy subjects (mean age: 24·6 ± 2·4 years) were involved in the investigation. Intra-muscular electromyographic (EMG) activity of the right masseter was recorded in different regions of the muscle. MUs were identified by the use of decomposition software, and root-mean-square (RMS) values were calculated for each experimental condition. Six hundred and eleven decomposed MUs with significantly (P < 0·001) different jaw relation-specific recruitment behaviour were organised into localised MU task groups. MUs with different task specificity in seven examined tasks were observed. The RMS EMG values obtained from the different recording sites were also significantly (P < 0·01) different between tasks. Overall MU recruitment was significantly (P < 0·05) greater in the deep masseter than in the superficial muscle. The number of recruited MUs and the RMS EMG values decreased significantly (P < 0·01) with increasing jaw separation. This investigation revealed differential MU recruitment behaviour in discrete subvolumes of the masseter in response to small changes in vertical jaw relations. These fine-motor skills might be responsible for its excellent functional adaptability and might also explain the successful management of temporomandibular disorder patients by somatic intervention, in particular by the use of oral splints. © 2015 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Smith, Samuel; Llinas, Juan-Pablo; Bokor, Jeffrey; Salahuddin, Sayeef
2018-01-01
Ballistic quantum transport calculations based on the non-equilbrium Green's function formalism show that field-effect transistor devices made from chevron-type graphene nanoribbons (CGNRs) could exhibit negative differential resistance with peak-to-valley ratios in excess of 4800 at room temperature as well as steep-slope switching with 6 mV/decade subtheshold swing over five orders of magnitude and ON-currents of 88$\\mu$A/$\\mu$m. This is enabled by the superlattice-like structure of these ribbons that have large periodic unit cells with regions of different effective bandgap, resulting in minibands and gaps in the density of states above the conduction band edge. The CGNR ribbon used in our proposed device has been previously fabricated with bottom-up chemical synthesis techniques and could be incorporated into an experimentally-realizable structure.
Quantum dynamics of the Mu+H2(HD,D2) and H+MuH(MuD) reactions
NASA Astrophysics Data System (ADS)
Tsuda, Ken-ichiro; Moribayashi, Kengo; Nakamura, Hiroki
1995-10-01
Quantum mechanically accurate calculations are carried out for the following reactions involving muonium atom (Mu) using the hyperspherical coordinate approach: Mu+H2→MuH+H, Mu+D2→MuD+D, Mu+HD→MuH(MuD)+D(H), H+MuH→MuH+H, and H+MuD ↔MuH+D. The initial vibrational state is restricted to the ground state (vi=0) and the collision energies considered are up to ˜1.2 eV. The various aspects of the dynamics, such as the isotope effects, the initial rotational state (ji) dependence, and the final rotational state (jf) distribution are analyzed for a wide range of ji and jf. Some of the isotope effects can be interpreted in terms of the variations in reaction barrier and endothermicity. The following two intriguing features are also found: (1) strong enhancement of reaction by initial rotational excitation, and (2) oscillation of integral cross section as a function of collision energy in the case of the Mu-transfer reactions.
Deriving proper measurement uncertainty from Internal Quality Control data: An impossible mission?
Ceriotti, Ferruccio
2018-03-30
Measurement uncertainty (MU) is a "non-negative parameter characterizing the dispersion of the quantity values being attributed to a measurand, based on the information used". In the clinical laboratory the most convenient way to calculate MU is the "top down" approach based on the use of Internal Quality Control data. As indicated in the definition, MU depends on the information used for its calculation and so different estimates of MU can be obtained. The most problematic aspect is how to deal with bias. In fact bias is difficult to detect and quantify and it should be corrected including only the uncertainty derived from this correction. Several approaches to calculate MU starting from Internal Quality Control data are presented. The minimum requirement is to use only the intermediate precision data, provided to include 6 months of results obtained with a commutable quality control material at a concentration close to the clinical decision limit. This approach is the minimal requirement and it is convenient for all those measurands that are especially used for monitoring or where a reference measurement system does not exist and so a reference for calculating the bias is lacking. Other formulas including the uncertainty of the value of the calibrator, including the bias from a commutable certified reference material or from a material specifically prepared for trueness verification, including the bias derived from External Quality Assessment schemes or from historical mean of the laboratory are presented and commented. MU is an important parameter, but a single, agreed upon way to calculate it in a clinical laboratory is not yet available. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Uranium-lead isotope systematics of Mars inferred from the basaltic shergottite QUE 94201
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gaffney, A M; Borg, L E; Connelly, J N
2006-12-22
Uranium-lead ratios (commonly represented as {sup 238}U/{sup 204}Pb = {mu}) calculated for the sources of martian basalts preserve a record of petrogenetic processes that operated during early planetary differentiation and formation of martian geochemical reservoirs. To better define the range of {mu} values represented by the source regions of martian basalts, we completed U-Pb elemental and isotopic analyses on whole rock, mineral and leachate fractions from the martian meteorite Queen Alexandra Range 94201 (QUE 94201). The whole rock and silicate mineral fractions have unradiogenic Pb isotopic compositions that define a narrow range ({sup 206}Pb/{sup 204}Pb = 11.16-11.61). In contrast, themore » Pb isotopic compositions of weak HCl leachates are more variable and radiogenic. The intersection of the QUE 94201 data array with terrestrial Pb in {sup 206}Pb/{sup 204}Pb-{sup 207}Pb/{sup 204}Pb-{sup 208}Pb/{sup 204}Pb compositional space is consistent with varying amounts of terrestrial contamination in these fractions. We calculate that only 1-7% contamination is present in the purified silicate mineral and whole rock fractions, whereas the HCl leachates contain up to 86% terrestrial contamination. Despite the contamination, we are able to use the U-Pb data to determine the initial {sup 206}Pb/{sup 204}Pb of QUE 94201 (11.086 {+-} 0.008) and calculate the {mu} value of the QUE 94201 mantle source to be 1.823 {+-} 0.008. This is the lowest {mu} value calculated for any martian basalt source, and, when compared to the highest values determined for martian basalt sources, indicates that {mu} values in martian source reservoirs vary by at least 100%. The range of source {mu} values further indicates that the {mu} value of bulk silicate Mars is approximately three. The amount of variation in the {mu} values of the mantle sources ({mu} {approx} 2-4) is greater than can be explained by igneous processes involving silicate phases alone. We suggest the possibility that a small amount of sulfide crystallization may generate large extents of U-Pb fractionation during formation of the mantle sources of martian basalts.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jaeger, B.; Oleari, C.; Zeppenfeld, D.
2009-08-01
We present a next-to-leading order QCD calculation for e{sup +}{nu}{sub e}{mu}{sup +}{nu}{sub {mu}}jj and e{sup -}{nu}{sub e}{mu}{sup -}{nu}{sub {mu}}jj production via weak-boson fusion at a hadron collider in the form of a fully flexible parton-level Monte Carlo program, which allows for the calculation of experimentally accessible observables within realistic selection cuts. The QCD corrections to the integrated cross sections are found to be modest, while the shapes of some kinematical distributions change appreciably compared to leading order. The residual scale uncertainties of the next-to-leading order results are at the few-percent level.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martinez-Ovalle, S. A.; Barquero, R.; Gomez-Ros, J. M.
Purpose: To calculate absorbed doses due to neutrons in 87 organs/tissues for anthropomorphic phantoms, irradiated in position supine (head first into the gantry) with orientations anteroposterior (AP) and right-left (RLAT) with a 18 MV accelerator. Conversion factors from monitor units to {mu}Gy per neutron in organs, equivalent doses in organs/tissues, and effective doses, which permit to quantify stochastic risks, are estimated. Methods: MAX06 and FAX06 phantoms were modeled with MCNPX and irradiated with a 18 MV Varian Clinac 2100C/D accelerator whose geometry included a multileaf collimator. Two actual fields of a pelvic treatment were simulated using electron-photon-neutron coupled transport. Absorbedmore » doses due to neutrons were estimated from kerma. Equivalent doses were estimated using the radiation weighting factor corresponding to an average incident neutron energy 0.47 MeV. Statistical uncertainties associated to absorbed doses, as calculated by MCNPX, were also obtained. Results: Largest doses were absorbed in shallowest (with respect to the neutron pathway) organs. In {mu}GyMU{sup -1}, values of 2.66 (for penis) and 2.33 (for testes) were found in MAX06, and 1.68 (for breasts), 1.05 (for lenses of eyes), and 0.94 (for sublingual salivary glands) in FAX06, in AP orientation. In RLAT, the largest doses were found for bone tissues (leg) just at the entrance of the beam in the body (right side in our case). Values, in {mu}GyMU{sup -1}, of 1.09 in upper leg bone right spongiosa, for MAX06, and 0.63 in mandible spongiosa, for FAX06, were found. Except for gonads, liver, and stomach wall, equivalent doses found for FAX06 were, in both orientations, higher than for MAX06. Equivalent doses in AP are higher than in RLAT for all organs/tissues other than brain and liver. Effective doses of 12.6 and 4.1 {mu}SvMU{sup -1} were found for AP and RLAT, respectively. The organs/tissues with larger relative contributions to the effective dose were testes and breasts, in AP, and breasts and red marrow, in RLAT. Equivalent and effective doses obtained for MAX06/FAX06 were smaller (between 2 and 20 times) than those quoted for the mathematical phantoms ADAM/EVA in ICRP-74. Conclusions: The new calculations of conversion coefficients for neutron irradiation in AP and RLAT irradiation geometries show a reduction in the values of effective dose by factors 7 (AP) and 6 (RLAT) with respect to the old data obtained with mathematical phantoms. The existence of tissues or anatomical regions with maximum absorbed doses, such as penis, lens of eyes, fascia (part of connective tissue), etc., organs/tissues that classic mathematical phantoms did not include because they were not considered for the study of stochastic effects, has been revealed. Absorbed doses due to photons, obtained following the same simulation methodology, are larger than those due to neutrons, reaching values 100 times larger as the primary beam is approached. However, for organs far from the treated volume, absorbed photon doses can be up to three times smaller than neutron ones. Calculations using voxel phantoms permitted to know the organ dose conversion coefficients per MU due to secondary neutrons in the complete anatomy of a patient.« less
Monte Carlo based, patient-specific RapidArc QA using Linac log files.
Teke, Tony; Bergman, Alanah M; Kwa, William; Gill, Bradford; Duzenli, Cheryl; Popescu, I Antoniu
2010-01-01
A Monte Carlo (MC) based QA process to validate the dynamic beam delivery accuracy for Varian RapidArc (Varian Medical Systems, Palo Alto, CA) using Linac delivery log files (DynaLog) is presented. Using DynaLog file analysis and MC simulations, the goal of this article is to (a) confirm that adequate sampling is used in the RapidArc optimization algorithm (177 static gantry angles) and (b) to assess the physical machine performance [gantry angle and monitor unit (MU) delivery accuracy]. Ten clinically acceptable RapidArc treatment plans were generated for various tumor sites and delivered to a water-equivalent cylindrical phantom on the treatment unit. Three Monte Carlo simulations were performed to calculate dose to the CT phantom image set: (a) One using a series of static gantry angles defined by 177 control points with treatment planning system (TPS) MLC control files (planning files), (b) one using continuous gantry rotation with TPS generated MLC control files, and (c) one using continuous gantry rotation with actual Linac delivery log files. Monte Carlo simulated dose distributions are compared to both ionization chamber point measurements and with RapidArc TPS calculated doses. The 3D dose distributions were compared using a 3D gamma-factor analysis, employing a 3%/3 mm distance-to-agreement criterion. The dose difference between MC simulations, TPS, and ionization chamber point measurements was less than 2.1%. For all plans, the MC calculated 3D dose distributions agreed well with the TPS calculated doses (gamma-factor values were less than 1 for more than 95% of the points considered). Machine performance QA was supplemented with an extensive DynaLog file analysis. A DynaLog file analysis showed that leaf position errors were less than 1 mm for 94% of the time and there were no leaf errors greater than 2.5 mm. The mean standard deviation in MU and gantry angle were 0.052 MU and 0.355 degrees, respectively, for the ten cases analyzed. The accuracy and flexibility of the Monte Carlo based RapidArc QA system were demonstrated. Good machine performance and accurate dose distribution delivery of RapidArc plans were observed. The sampling used in the TPS optimization algorithm was found to be adequate.
Surgeon contribution to hospital bottom line: not all are created equal.
Resnick, Andrew S; Corrigan, Diane; Mullen, James L; Kaiser, Larry R
2005-10-01
We hypothesized that surgeon productivity is directly related to hospital operating margin, but significant variation in margin contribution exists between specialties. As the independent practitioner becomes an endangered species, it is critical to better understand the surgeon's importance to a hospital's bottom line. An appreciation of surgeon contribution to hospital profitability may prove useful in negotiations relating to full-time employment or other models. Surgeon total relative value units (RVUs), a measure of productivity, were collected from operating room (OR) logs. Annual hospital margin per specialty was provided by hospital finance. Hospital margin data were normalized by dividing by a constant such that the highest relative hospital margin (RHM) in fiscal year 2004 expressed as margin units (mu) was 1 million mu. For each specialty, data analyzed included RHM/OR HR, RHM/case, and RHM/RVU. Thoracic (34.55 mu/RVU) and transplant (25.13 mu/RVU) were the biggest contributors to hospital margin. Plastics (-0.57 mu/RVU), maxillofacial (1.41 mu/RVU), and gynecology (1.66 mu/RVU) contributed least to hospital margin. Relative hospital margin per OR HR for transplant slightly exceeded thoracic (275.74 mu vs 233.94 mu) at the top and plastics and maxillofacial contributed the least (-3.83 mu/OR HR vs 9.36 mu/OR HR). Surgeons contribute significantly to hospital margin with certain specialties being more profitable than others. Payer mix, the penetration of managed care, and negotiated contracts as well as a number of other factors all have an impact on an individual hospital's margin. Surgeons should be fully cognizant of their significant influence in the marketplace.
Homayoon, Zahra; Jambrina, Pablo G; Aoiz, F Javier; Bowman, Joel M
2012-07-14
In a previous paper [P. G. Jambrina et al., J. Chem. Phys. 135, 034310 (2011)] various calculations of the rate coefficient for the Mu + H(2) → MuH + H reaction were presented and compared to experiment. The widely used standard quasiclassical trajectory (QCT) method was shown to overestimate the rate coefficients by several orders of magnitude over the temperature range 200-1000 K. This was attributed to a major failure of that method to describe the correct threshold for the reaction owing to the large difference in zero-point energies (ZPE) of the reactant H(2) and product MuH (∼0.32 eV). In this Communication we show that by performing standard QCT calculations for the reverse reaction and then applying detailed balance, the resulting rate coefficient is in very good agreement with the other computational results that respect the ZPE, (as well as with the experiment) but which are more demanding computationally.
NASA Astrophysics Data System (ADS)
Homayoon, Zahra; Jambrina, Pablo G.; Aoiz, F. Javier; Bowman, Joel M.
2012-07-01
In a previous paper [P. G. Jambrina et al., J. Chem. Phys. 135, 034310 (2011), 10.1063/1.3611400] various calculations of the rate coefficient for the Mu + H2 → MuH + H reaction were presented and compared to experiment. The widely used standard quasiclassical trajectory (QCT) method was shown to overestimate the rate coefficients by several orders of magnitude over the temperature range 200-1000 K. This was attributed to a major failure of that method to describe the correct threshold for the reaction owing to the large difference in zero-point energies (ZPE) of the reactant H2 and product MuH (˜0.32 eV). In this Communication we show that by performing standard QCT calculations for the reverse reaction and then applying detailed balance, the resulting rate coefficient is in very good agreement with the other computational results that respect the ZPE, (as well as with the experiment) but which are more demanding computationally.
Padoan, Andrea; Antonelli, Giorgia; Aita, Ada; Sciacovelli, Laura; Plebani, Mario
2017-10-26
The present study was prompted by the ISO 15189 requirements that medical laboratories should estimate measurement uncertainty (MU). The method used to estimate MU included the: a) identification of quantitative tests, b) classification of tests in relation to their clinical purpose, and c) identification of criteria to estimate the different MU components. Imprecision was estimated using long-term internal quality control (IQC) results of the year 2016, while external quality assessment schemes (EQAs) results obtained in the period 2015-2016 were used to estimate bias and bias uncertainty. A total of 263 measurement procedures (MPs) were analyzed. On the basis of test purpose, in 51 MPs imprecision only was used to estimate MU; in the remaining MPs, the bias component was not estimable for 22 MPs because EQAs results did not provide reliable statistics. For a total of 28 MPs, two or more MU values were calculated on the basis of analyte concentration levels. Overall, results showed that uncertainty of bias is a minor factor contributing to MU, the bias component being the most relevant contributor to all the studied sample matrices. The model chosen for MU estimation allowed us to derive a standardized approach for bias calculation, with respect to the fitness-for-purpose of test results. Measurement uncertainty estimation could readily be implemented in medical laboratories as a useful tool in monitoring the analytical quality of test results since they are calculated using a combination of both the long-term imprecision IQC results and bias, on the basis of EQAs results.
Chen, Guang-Pei; Ahunbay, Ergun; Li, X Allen
2016-04-01
To develop an integrated quality assurance (QA) software tool for online replanning capable of efficiently and automatically checking radiation treatment (RT) planning parameters and gross plan quality, verifying treatment plan data transfer from treatment planning system (TPS) to record and verify (R&V) system, performing a secondary monitor unit (MU) calculation with or without a presence of a magnetic field from MR-Linac, and validating the delivery record consistency with the plan. The software tool, named ArtQA, was developed to obtain and compare plan and treatment parameters from both the TPS and the R&V system database. The TPS data are accessed via direct file reading and the R&V data are retrieved via open database connectivity and structured query language. Plan quality is evaluated with both the logical consistency of planning parameters and the achieved dose-volume histograms. Beams in between the TPS and R&V system are matched based on geometry configurations. To consider the effect of a 1.5 T transverse magnetic field from MR-Linac in the secondary MU calculation, a method based on modified Clarkson integration algorithm was developed and tested for a series of clinical situations. ArtQA has been used in their clinic and can quickly detect inconsistencies and deviations in the entire RT planning process. With the use of the ArtQA tool, the efficiency for plan check including plan quality, data transfer, and delivery check can be improved by at least 60%. The newly developed independent MU calculation tool for MR-Linac reduces the difference between the plan and calculated MUs by 10%. The software tool ArtQA can be used to perform a comprehensive QA check from planning to delivery with conventional Linac or MR-Linac and is an essential tool for online replanning where the QA check needs to be performed rapidly.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Guang-Pei, E-mail: gpchen@mcw.edu; Ahunbay, Ergun; Li, X. Allen
Purpose: To develop an integrated quality assurance (QA) software tool for online replanning capable of efficiently and automatically checking radiation treatment (RT) planning parameters and gross plan quality, verifying treatment plan data transfer from treatment planning system (TPS) to record and verify (R&V) system, performing a secondary monitor unit (MU) calculation with or without a presence of a magnetic field from MR-Linac, and validating the delivery record consistency with the plan. Methods: The software tool, named ArtQA, was developed to obtain and compare plan and treatment parameters from both the TPS and the R&V system database. The TPS data aremore » accessed via direct file reading and the R&V data are retrieved via open database connectivity and structured query language. Plan quality is evaluated with both the logical consistency of planning parameters and the achieved dose–volume histograms. Beams in between the TPS and R&V system are matched based on geometry configurations. To consider the effect of a 1.5 T transverse magnetic field from MR-Linac in the secondary MU calculation, a method based on modified Clarkson integration algorithm was developed and tested for a series of clinical situations. Results: ArtQA has been used in their clinic and can quickly detect inconsistencies and deviations in the entire RT planning process. With the use of the ArtQA tool, the efficiency for plan check including plan quality, data transfer, and delivery check can be improved by at least 60%. The newly developed independent MU calculation tool for MR-Linac reduces the difference between the plan and calculated MUs by 10%. Conclusions: The software tool ArtQA can be used to perform a comprehensive QA check from planning to delivery with conventional Linac or MR-Linac and is an essential tool for online replanning where the QA check needs to be performed rapidly.« less
SU-E-T-168: Characterization of Neutrons From the TrueBeam Treatment Head
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sawkey, D; Svatos, M
2015-06-15
Purpose: Calculate neutron production and transport in the TrueBeam treatment head, as input for vault design and phantom dose calculations. Methods: A detailed model of the treatment head, including shielding components off the beam axis, was created from manufacturer’s engineering drawings. Simulations were done with Geant4 for the 18X, 15X, 10X and 10FFF beams, tuned to match measured dose distributions inside the treatment field. Particles were recorded on a 70 cm radius sphere surrounding the treatment head enabling input into simulations of vaults. Results: For the 18X beam, 11×10{sup 9} neutrons/MU were observed. The energy spectrum was a broad peakmore » with average energy 0.37 MeV. With jaws closed, 48% of the neutrons were generated in the primary collimator, 18% in the jaws, 12% in the target, and 10% in the flattening filter. With wide open jaws, few neutrons were produced in the jaws and consequently total neutron production dropped to 8.5×10{sup 9} neutrons/MU. Angular distributions were greatest along the beam axis (12×10{sup 9} neutrons/MU/sr, within 2 deg of the beam axis) and antiparallel to the beam axis (7×10{sup 9} neutrons/MU/sr). Peaks were observed in the neutron energy spectrum, corresponding to elastic scattering resonances in the shielding materials. Neutron production was lower for the other beams studied: 4.1×10{sup 9} neutrons/MU for 15X, 0.38×10{sup 9} neutrons/MU for 10X, and 0.22×10{sup 9} neutrons/MU for 10FFF. Despite dissimilar treatment head geometries and materials, the neutron production and energy spectrum were similar to those reported for Clinac accelerators. Conclusion: Detailed neutron production and leakage calculations for the TrueBeam treatment head were done. Unlike other studies, results are independent of the surrounding vault, enabling vault design calculations.« less
Motor unit size estimation: confrontation of surface EMG with macro EMG.
Roeleveld, K; Stegeman, D F; Falck, B; Stålberg, E V
1997-06-01
Surface EMG (SEMG) is little used for diagnostic purposes in clinical neurophysiology, mainly because it provides little direct information on individual motor units (MUs). One of the techniques to estimate the MU size is intra-muscular Macro EMG. The present study compares SEMG with Macro EMG. Fifty-eight channel SEMG was recorded simultaneously with Macro EMG. Individual MUPs were obtained by single fiber triggered averaging. All recordings were made from the biceps brachii of healthy subjects during voluntary contraction at low force. High positive correlations were found between all Macro and Surface motor unit potential (MUP) parameters: area, peak-to-peak amplitude, negative peak amplitude and positive peak amplitude. The MUPs recorded with SEMG were dependent on the distance between the MU and the skin surface. Normalizing the SEMG parameters for MU location did not improve the correlation coefficient between the parameters of both techniques. The two measurement techniques had almost the same relative range in MUP parameters in any individual subject compared to the others, especially after normalizing the surface MUP parameters for MU location. MUPs recorded with this type of SEMG provide useful information about the MU size.
Study of cosmic ray interaction model based on atmospheric muons for the neutrino flux calculation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sanuki, T.; Honda, M.; Kajita, T.
2007-02-15
We have studied the hadronic interaction for the calculation of the atmospheric neutrino flux by summarizing the accurately measured atmospheric muon flux data and comparing with simulations. We find the atmospheric muon and neutrino fluxes respond to errors in the {pi}-production of the hadronic interaction similarly, and compare the atmospheric muon flux calculated using the HKKM04 [M. Honda, T. Kajita, K. Kasahara, and S. Midorikawa, Phys. Rev. D 70, 043008 (2004).] code with experimental measurements. The {mu}{sup +}+{mu}{sup -} data show good agreement in the 1{approx}30 GeV/c range, but a large disagreement above 30 GeV/c. The {mu}{sup +}/{mu}{sup -} ratiomore » shows sizable differences at lower and higher momenta for opposite directions. As the disagreements are considered to be due to assumptions in the hadronic interaction model, we try to improve it phenomenologically based on the quark parton model. The improved interaction model reproduces the observed muon flux data well. The calculation of the atmospheric neutrino flux will be reported in the following paper [M. Honda et al., Phys. Rev. D 75, 043006 (2007).].« less
Byrnes, Matthew J; Chisholm, Malcolm H; Patmore, Nathan J
2005-12-12
The reactions between M2(O2CtBu)4, where M=Mo or W, and thienyl-3,4-dicarboxylic acid (0.5-1.5 equiv) in toluene proceed via a series of detectable intermediates to the compounds M8(O2CtBu)4(mu-SC4H2-3,4-{CO2}2)6, which are isolated as air-sensitive yellow (M=Mo) or red (M=W) powders and show parent molecular ions in their mass spectra (MALDI). The structure of the molybdenum complex was determined by single-crystal X-ray crystallography and shown to contain an unusual M8 polygon involving four Mo2 quadruply bonded units linked via the agency of the six 3,4-thienylcarboxylate groups. The structure has crystallographically imposed S4 symmetry and may be described in terms of a highly distorted tetrahedron of Mo2 units or a bisphenoid in which two Mo2 units are linked by a thienyldicarboxylate such that intramolecular Mo2...O bonding is present, while the other thienylcarboxylate bridges merely serve to link these two [Mo2]...[Mo2] units together. The color of the compounds arises from intense M2 delta-to-thienyl pi transitions and, in THF, the complexes are redox-active and show four successive quasi-reversible oxidation waves. The [M8]+ radical cations, generated by one-electron oxidation with AgPF6, are shown to be valence-trapped (class II) by UV-vis-near-IR and electron paramagnetic resonance spectroscopy. These results are supported by the electronic structure calculations on model compounds M8(O2CH)4(mu-SC4H2-3,4-{CO}2)6 employing density functional theory that reveal only a small splitting of the M2 delta manifold via mixing with the 3,4-thienylcarboxylate pi system.
Surgeon Contribution to Hospital Bottom Line
Resnick, Andrew S.; Corrigan, Diane; Mullen, James L.; Kaiser, Larry R.
2005-01-01
Objective: We hypothesized that surgeon productivity is directly related to hospital operating margin, but significant variation in margin contribution exists between specialties. Summary Background Data: As the independent practitioner becomes an endangered species, it is critical to better understand the surgeon's importance to a hospital's bottom line. An appreciation of surgeon contribution to hospital profitability may prove useful in negotiations relating to full-time employment or other models. Methods: Surgeon total relative value units (RVUs), a measure of productivity, were collected from operating room (OR) logs. Annual hospital margin per specialty was provided by hospital finance. Hospital margin data were normalized by dividing by a constant such that the highest relative hospital margin (RHM) in fiscal year 2004 expressed as margin units (mu) was 1 million mu. For each specialty, data analyzed included RHM/OR HR, RHM/case, and RHM/RVU. Results: Thoracic (34.55 mu/RVU) and transplant (25.13 mu/RVU) were the biggest contributors to hospital margin. Plastics (−0.57 mu/RVU), maxillofacial (1.41 mu/RVU), and gynecology (1.66 mu/RVU) contributed least to hospital margin. Relative hospital margin per OR HR for transplant slightly exceeded thoracic (275.74 mu vs 233.94 mu) at the top and plastics and maxillofacial contributed the least (−3.83 mu/OR HR vs 9.36 mu/OR HR). Conclusions: Surgeons contribute significantly to hospital margin with certain specialties being more profitable than others. Payer mix, the penetration of managed care, and negotiated contracts as well as a number of other factors all have an impact on an individual hospital's margin. Surgeons should be fully cognizant of their significant influence in the marketplace. PMID:16192813
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pereira, Wagner de S; Universidade Federal Fluminense, Programa de Pos-graduacao em Biologia Marinha; Kelecom, Alphonse
2008-08-07
The uranium mining at Caetite (Uranium Concentrate Unit--URA) is in its operational phase. Aiming to estimate the radiological environmental impact of the URA, a monitoring program is underway. In order to preserve the biota of the deleterious effects from radiation and to act in a pro-active way as expected from a licensing body, the present work aims to use an environmental protection methodology based on the calculation of absorbed dose rate in biota. Thus, selected target organism was the Tilapia fish (Tilapia nilotica, Linnaeus, 1758) and the radionuclides were: uranium (U-238), thorium (Th-232), radium (Ra-226 and Ra-228) and lead (Pb-210).more » As, in Brazil there are no radiation exposure limits adopted for biota the value proposed by the Department of Energy (DOE) of the United States of 3.5x10{sup 3} {mu}Gy y{sup -1} has been used. The derived absorbed dose rate calculated for Tilapia was 2.51x10{sup 0} {mu}Gy y{sup -1}, that is less than 0.1% of the dose limit established by DOE. The critical radionuclide was Ra-226, with 56% of the absorbed dose rate, followed by U-238 with 34% and Th-232 with 9%. This value of 0.1% of the limit allows to state that, in the operational conditions analyzed, natural radionuclides do not represent a radiological problem to biota.« less
NASA Technical Reports Server (NTRS)
Wolpert, David H. (Inventor)
2003-01-01
Distributed approach for determining a path connecting adjacent network nodes, for probabilistically or deterministically transporting an entity, with entity characteristic mu from a source node to a destination node. Each node i is directly connected to an arbitrary number J(mu) of nodes, labeled or numbered j=jl, j2, .... jJ(mu). In a deterministic version, a J(mu)-component baseline proportion vector p(i;mu) is associated with node i. A J(mu)-component applied proportion vector p*(i;mu) is determined from p(i;mu) to preclude an entity visiting a node more than once. Third and fourth J(mu)-component vectors, with components iteratively determined by Target(i;n(mu);mu),=alpha(mu).Target(i;n(mu)-1;mu)j+beta(mu).p* (i;mu)j and Actual(i;n(mu);+a(mu)j. Actual(i;n(mu)-l;mu)j+beta(mu).Sent(i;j'(mu);n(mu)-1;mu)j, are computed, where n(mu) is an entity sequence index and alpha(mu) and beta(mu) are selected numbers. In one embodiment, at each node i, the node j=j'(mu) with the largest vector component difference, Target(i;n(mu);mu)j'- Actual (i;n(mu);mu)j'. is chosen for the next link for entity transport, except in special gap circumstances, where the same link is optionally used for transporting consecutively arriving entities. The network nodes may be computer-controlled routers that switch collections of packets, frames, cells or other information units. Alternatively, the nodes may be waypoints for movement of physical items in a network or for transformation of a physical item. The nodes may be states of an entity undergoing state transitions, where allowed transitions are specified by the network and/or the destination node.
Buise, Marc P; Ince, Can; Tilanus, Hugo W; Klein, Jan; Gommers, Diederik; van Bommel, Jasper
2005-04-01
Esophagectomy followed by gastric tube reconstruction is the surgical treatment of choice for patients with esophageal cancer. Complications of the cervical anastomosis are associated with impaired microvascular blood flow (MBF) and ischemia in the gastric fundus. The aim of the present study was to differentiate whether the decrease in MBF is a result of arterial insufficiency or of venous congestion. To do this we assessed MBF, microvascular hemoglobin oxygen saturation (muHbSo(2)), and microvascular hemoglobin concentration (muHbcon) simultaneously during different stages of gastric tube reconstruction. In 14 patients, MBF was determined with laser Doppler flowmetry, and muHbSo(2) and muHbcon were determined with reflectance spectro- photometry. After completion of the anastomosis, nitroglycerin was applied at the fundus. Although MBF did not change significantly in the pylorus, MBF decreased progressively during surgery in the fundus from 210 +/- 18 Arbitrary Units at baseline (normal stomach) to 52 +/- 9 Arbitrary Units after completion of reconstruction (mean +/- sem; P < 0.05). There was no change in muHbSo(2) and muHbcon during the reconstruction. After application of nitroglycerin, MBF doubled. We conclude that MBF decreases during gastric tube reconstruction but that muHbSo(2) and muHbcon do not. This decrease might be the result of venous congestion, which can partly be counteracted by application of nitroglycerin.
Pollock, C L; Ivanova, T D; Hunt, M A; Garland, S J
2015-10-01
This study investigated the behavior of medial gastrocnemius (GM) motor units (MU) during external perturbations in standing in people with chronic stroke. GM MUs were recorded in standing while anteriorly-directed perturbations were introduced by applying loads of 1% body mass (BM) at the pelvis every 25-40s until 5% BM was maintained. Joint kinematics, surface electromyography (EMG), and force platform measurements were assessed. Although external loads caused a forward progression of the anterior-posterior centre of pressure (APCOP), people with stroke decreased APCOP velocity and centre of mass (COM) velocity immediately following the highest perturbations, thereby limiting movement velocity in response to perturbations. MU firing rate did not increase with loading but the GM EMG magnitude increased, reflecting MU recruitment. MU inter spike interval (ISI) during the dynamic response was negatively correlated with COM velocity and hip angular velocity. The GM utilized primarily MU recruitment to maintain standing during external perturbations. The lack of MU firing rate modulation occurred with a change in postural central set. However, the relationship of MU firing rate with kinematic variables suggests underlying long-loop responses may be somewhat intact after stroke. People with stroke demonstrate alterations in postural control strategies which may explain MU behavior with external perturbations. Copyright © 2014 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
Pressure broadening of the ((dt. mu. )dee)* formation resonances
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cohen, J.S.; Leon, M.; Padial, N.T.
1988-12-27
The treatment of ((dt..mu..)dee)* formation at high densities as a pressure broadening process is discussed. Cross sections for collisions of the complex (dt..mu..)dee, and of the D/sub 2/ molecule from which it is formed, with the bath molecules have been accurately calculated. These cross sections are used to calculate the collisional width in three variations of the impact approximation that have been proposed for this problem. In general, the quasistatic approximation is shown to satisfy the usual conditions of muon-catalyzed fusion better than does the impact approximation. A preliminary rough treatment is presented to illustrate the quasistatic approximation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chakraborty, B.; Davies, C. T. H.; DeTar, C.
All lattice-QCD calculations of the hadronic-vacuum-polarization contribution to the muon’s anomalous magnetic moment to date have been performed with degenerate up- and down-quark masses. Here we calculate directly the strong-isospin-breaking correction tomore » $${a}_{{\\mu}}^{\\mathrm{HVP}}$$ for the first time with physical values of $${m}_{u}$$ and $${m}_{d}$$ and dynamical $u$, $d$, $s$, and $c$ quarks, thereby removing this important source of systematic uncertainty. We obtain a relative shift to be applied to lattice-QCD results obtained with degenerate light-quark masses of $${\\delta}{a}_{{\\mu}}^{\\mathrm{HVP},{m}_{u}{\
Chakraborty, B.; Davies, C. T. H.; DeTar, C.; ...
2018-04-12
All lattice-QCD calculations of the hadronic-vacuum-polarization contribution to the muon’s anomalous magnetic moment to date have been performed with degenerate up- and down-quark masses. Here we calculate directly the strong-isospin-breaking correction tomore » $${a}_{{\\mu}}^{\\mathrm{HVP}}$$ for the first time with physical values of $${m}_{u}$$ and $${m}_{d}$$ and dynamical $u$, $d$, $s$, and $c$ quarks, thereby removing this important source of systematic uncertainty. We obtain a relative shift to be applied to lattice-QCD results obtained with degenerate light-quark masses of $${\\delta}{a}_{{\\mu}}^{\\mathrm{HVP},{m}_{u}{\
High-precision evaluation of the magnetic moment of the helion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neronov, Yu. I., E-mail: yineronov@mail.ru; Seregin, N. N.
NMR spectra of samples containing a mixture of hydrogen deuteride HD with pressure of about 80 atm and helium-3 with partial pressure of about 1 atm are analyzed. The ratio of the resonance frequencies of the nuclei, F({sup 3}He)/F(H{sub 2}), is determined to be 0.761786594(2), which is equal to the magnetic moment of the helion (bound in a helium atom) in the units of the magnetic moment of a proton (bound in molecular hydrogen). The uncertainty of two digits in the last place corresponds to a relative error of {delta}[F({sup 3}He)/F(H{sub 2})] = 2.6 Multiplication-Sign 10{sup -9}. The use ofmore » the known calculated data on the shielding of nuclei in the helium-3 atom ({sigma}({sup 3}He) = 59924(2) Multiplication-Sign 10{sup -9}) and on the shielding of protons in hydrogen ({sigma}(H{sub 2}) = 26288(2) Multiplication-Sign 10{sup -9}) yields a value of {mu}({sup 3}He)/{mu}{sub p} = -0.761812217(3) for the free magnetic moment of the helion in the units of the proton magnetic moment.« less
SU-C-BRC-07: Parametrized GPU Accelerated Electron Monte Carlo Second Check
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haywood, J
Purpose: I am presenting a parameterized 3D GPU accelerated electron Monte Carlo second check program. Method: I wrote the 3D grid dose calculation algorithm in CUDA and utilized an NVIDIA GeForce GTX 780 Ti to run all of the calculations. The electron path beyond the distal end of the cone is governed by four parameters: the amplitude of scattering (AMP), the mean and width of a Gaussian energy distribution (E and α), and the percentage of photons. In my code, I adjusted all parameters until the calculated PDD and profile fit the measured 10×10 open beam data within 1%/1mm. Imore » then wrote a user interface for reading the DICOM treatment plan and images in Python. In order to verify the algorithm, I calculated 3D dose distributions on a variety of phantoms and geometries, and compared them with the Eclipse eMC calculations. I also calculated several patient specific dose distributions, including a nose and an ear. Finally, I compared my algorithm’s computation times to Eclipse’s. Results: The calculated MU for all of the investigated geometries agree with the TPS within the TG-114 action level of 5%. The MU for the nose was < 0.5 % different while the MU for the ear at 105 SSD was ∼2 %. Calculation times for a 12MeV 10×10 open beam ranged from 1 second for a 2.5 mm grid resolution with ∼15 million particles to 33 seconds on a 1 mm grid with ∼460 million particles. Eclipse calculation runtimes distributed over 10 FAS workers were 9 seconds to 15 minutes respectively. Conclusion: The GPU accelerated second check allows quick MU verification while accounting for patient specific geometry and heterogeneity.« less
Motor unit firing rate patterns during voluntary muscle force generation: a simulation study
NASA Astrophysics Data System (ADS)
Hu, Xiaogang; Rymer, William Z.; Suresh, Nina L.
2014-04-01
Objective. Muscle force is generated by a combination of motor unit (MU) recruitment and changes in the discharge rate of active MUs. There have been two basic MU recruitment and firing rate paradigms reported in the literature, which describe the control of the MUs during force generation. The first (termed the reverse ‘onion skin’ profile), exhibits lower firing rates for lower threshold units, with higher firing rates occurring in higher threshold units. The second (termed the ‘onion skin’ profile), exhibits an inverse arrangement, with lower threshold units reaching higher firing rates. Approach. Using a simulation of the MU activity in a hand muscle, this study examined the force generation capacity and the variability of the muscle force magnitude at different excitation levels of the MU pool under these two different MU control paradigms. We sought to determine which rate/recruitment scheme was more efficient for force generation, and which scheme gave rise to the lowest force variability. Main results. We found that the force output of both firing patterns leads to graded force output at low excitation levels, and that the force generation capacity of the two different paradigms diverged around 50% excitation. In the reverse ‘onion skin’ pattern, at 100% excitation, the force output reached up to 88% of maximum force, whereas for the ‘onion skin’ pattern, the force output only reached up to 54% of maximum force at 100% excitation. The force variability was lower at the low to moderate force levels under the ‘onion skin’ paradigm than with the reverse ‘onion skin’ firing patterns, but this effect was reversed at high force levels. Significance. This study captures the influence of MU recruitment and firing rate organization on muscle force properties, and our results suggest that the different firing organizations can be beneficial at different levels of voluntary muscle force generation and perhaps for different tasks.
Evaluation of an empirical monitor output estimation in carbon ion radiotherapy.
Matsumura, Akihiko; Yusa, Ken; Kanai, Tatsuaki; Mizota, Manabu; Ohno, Tatsuya; Nakano, Takashi
2015-09-01
A conventional broad beam method is applied to carbon ion radiotherapy at Gunma University Heavy Ion Medical Center. According to this method, accelerated carbon ions are scattered by various beam line devices to form 3D dose distribution. The physical dose per monitor unit (d/MU) at the isocenter, therefore, depends on beam line parameters and should be calibrated by a measurement in clinical practice. This study aims to develop a calculation algorithm for d/MU using beam line parameters. Two major factors, the range shifter dependence and the field aperture effect, are measured via PinPoint chamber in a water phantom, which is an identical setup as that used for monitor calibration in clinical practice. An empirical monitor calibration method based on measurement results is developed using a simple algorithm utilizing a linear function and a double Gaussian pencil beam distribution to express the range shifter dependence and the field aperture effect. The range shifter dependence and the field aperture effect are evaluated to have errors of 0.2% and 0.5%, respectively. The proposed method has successfully estimated d/MU with a difference of less than 1% with respect to the measurement results. Taking the measurement deviation of about 0.3% into account, this result is sufficiently accurate for clinical applications. An empirical procedure to estimate d/MU with a simple algorithm is established in this research. This procedure allows them to use the beam time for more treatments, quality assurances, and other research endeavors.
Managing internode data communications for an uninitialized process in a parallel computer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Archer, Charles J; Blocksome, Michael A; Miller, Douglas R
2014-05-20
A parallel computer includes nodes, each having main memory and a messaging unit (MU). Each MU includes computer memory, which in turn includes, MU message buffers. Each MU message buffer is associated with an uninitialized process on the compute node. In the parallel computer, managing internode data communications for an uninitialized process includes: receiving, by an MU of a compute node, one or more data communications messages in an MU message buffer associated with an uninitialized process on the compute node; determining, by an application agent, that the MU message buffer associated with the uninitialized process is full prior tomore » initialization of the uninitialized process; establishing, by the application agent, a temporary message buffer for the uninitialized process in main computer memory; and moving, by the application agent, data communications messages from the MU message buffer associated with the uninitialized process to the temporary message buffer in main computer memory.« less
Managing internode data communications for an uninitialized process in a parallel computer
Archer, Charles J; Blocksome, Michael A; Miller, Douglas R; Parker, Jeffrey J; Ratterman, Joseph D; Smith, Brian E
2014-05-20
A parallel computer includes nodes, each having main memory and a messaging unit (MU). Each MU includes computer memory, which in turn includes, MU message buffers. Each MU message buffer is associated with an uninitialized process on the compute node. In the parallel computer, managing internode data communications for an uninitialized process includes: receiving, by an MU of a compute node, one or more data communications messages in an MU message buffer associated with an uninitialized process on the compute node; determining, by an application agent, that the MU message buffer associated with the uninitialized process is full prior to initialization of the uninitialized process; establishing, by the application agent, a temporary message buffer for the uninitialized process in main computer memory; and moving, by the application agent, data communications messages from the MU message buffer associated with the uninitialized process to the temporary message buffer in main computer memory.
ERIC Educational Resources Information Center
Sevilla, F. J.; Olivares-Quiroz, L.
2012-01-01
In this work, we address the concept of the chemical potential [mu] in classical and quantum gases towards the calculation of the equation of state [mu] = [mu](n, T) where n is the particle density and "T" the absolute temperature using the methods of equilibrium statistical mechanics. Two cases seldom discussed in elementary textbooks are…
Loss of motor unit size and quadriceps strength over 10 years in post-polio syndrome.
Bickerstaffe, A; van Dijk, J P; Beelen, A; Zwarts, M J; Nollet, F
2014-06-01
To investigate whether strength decline in post-polio syndrome (PPS) results from excessive distal axonal degeneration of enlarged motor units. We assessed changes over 10 years in isometric quadriceps strength, mean motor unit action potential (MUAP) size, root mean squared (RMS) amplitude, and level of interference (LOI) in 47 patients with PPS and 12 healthy controls, using high density surface EMG. At baseline, all patients had symptomatic quadriceps dysfunction, evidenced by transmission defects on single-fibre EMG. MU size and strength declined significantly by 20% and 15%, respectively in patients with PPS. Those with the largest initial MU sizes exhibited the greatest losses of mean MU size (27%) and proportional decreases in quadriceps strength (23%). Initial strength, change in LOI and change in RMS amplitude together explained 35% of the variability in strength changes in patients. MU size of controls did not change, although they lost 29% strength. MU size and strength declined concomitantly in a homogeneous cohort of patients with PPS and quadriceps dysfunction. This long term follow-up study provides evidence that size diminution of enlarged MUs combined with a reduced number of active MUs contributes to the gradual strength decline in PPS. Copyright © 2013 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
Motor unit and muscle fiber type grouping after peripheral nerve injury in the rat.
Gordon, Tessa; de Zepetnek, Joanne E Totosy
2016-11-01
Muscle unit (MU) fibers innervated by one motoneuron and corresponding muscle fiber types are normally distributed in a mosaic. We asked whether, 4-8months after common peroneal nerve transection and random surgical alignment of nerve stumps in rat tibialis anterior muscles 1) reinnervated MU muscle and muscle fiber type clumping is invariant and 2) slow and fast motoneurons regenerate their nerve fibers within original endoneurial pathways. MU contractile forces were recorded in vivo, the MUs classified into types according to their contractile speed and fatigability, and one MU subjected to alternate exhaustive stimulation-recovery cycles to deplete glycogen for histochemical MU fiber recognition and enumeration, and muscle fiber typing. MU muscle fibers occupied defined territories whose size increased with MU force and muscle fiber numbers in normal and reinnervated muscles. The reinnervated MU muscle fiber territories were significantly smaller, the fibers clumped within 1-3 groups in 90% of the MUs, and each fiber lying adjacent to another significantly more frequently. Most reinnervated slow muscle fibers were normally located in the deep muscle compartment but substantial numbers were located abnormally in the superficial compartment. Our findings that well reinnervated muscle fibers clump in small muscles contrast with our earlier findings of clumping in large muscles only when reinnervated MU numbers were significantly reduced. We conclude that fiber type clumping is predictive of muscle reinnervation in small but not large muscles. In the latter muscles, clumping is more indicative of sprouting after partial nerve injuries than of muscle reinnervation after complete nerve injuries. Copyright © 2016 Elsevier Inc. All rights reserved.
[Evaluation of myocardial uptake of beta-methyl-(123I)-iodophenylpentadecanoic acid (123I-BMIPP)].
Momose, M; Kobayashi, H; Saito, K; Matsumoto, N; Maki, M; Hosoda, S; Kusakabe, K
1994-12-01
To evaluate the myocardial uptake of beta-methyl-(123I)-iodophenylpentadecanoic acid (123I-BMIPP), nineteen patients with ischemic heart disease including left ventricular hypertrophy (mean age 63 +/- 7.8, 14 males and 5 females) underwent BMIPP myocardial scintigraphy. Myocardial uptake (MU) of BMIPP to the total injected dose was calculated from anterior view of the planar image in all subjects, and was compared with plasma glucose (BS), triglyceride (TG), and free fatty acid (FFA). It was also compared with left ventricular mass (LVM) calculated with echocardiography. MU was not related to BS, TG, and FFA, however had the positive correlation with LVM (r = 0.676, p < 0.01). Myocardial uptake per left ventricular mass (MU/LVM) had the negative correlation with LVM (r = -0.671, p < 0.01). Further studies for the significance of MU/LVM will be required.
SU-G-IeP4-06: Feasibility of External Beam Treatment Field Verification Using Cherenkov Imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Black, P; Na, Y; Wuu, C
2016-06-15
Purpose: Cherenkov light emission has been shown to correlate with ionizing radiation (IR) dose delivery in solid tissue. In order to properly correlate Cherenkov light images with real time dose delivery in a patient, we must account for geometric and intensity distortions arising from observation angle, as well as the effect of monitor units (MU) and field size on Cherenkov light emission. To test the feasibility of treatment field verification, we first focused on Cherenkov light emission efficiency based on MU and known field size (FS). Methods: Cherenkov light emission was captured using a PI-MAX4 intensified charge coupled device(ICCD) systemmore » (Princeton Instruments), positioned at a fixed angle of 40° relative to the beam central axis. A Varian TrueBeam linear accelerator (linac) was operated at 6MV and 600MU/min to deliver an Anterior-Posterior beam to a 5cm thick block phantom positioned at 100cm Source-to-Surface-Distance(SSD). FS of 10×10, 5×5, and 2×2cm{sup 2} were used. Before beam delivery projected light field images were acquired, ensuring that geometric distortions were consistent when measuring Cherenkov field discrepancies. Cherenkov image acquisition was triggered by linac target current. 500 frames were acquired for each FS. Composite images were created through summation of frames and background subtraction. MU per image was calculated based on linac pulse delay of 2.8ms. Cherenkov and projected light FS were evaluated using ImageJ software. Results: Mean Cherenkov FS discrepancies compared to light field were <0.5cm for 5.6, 2.8, and 8.6 MU for 10×10, 5×5, and 2×2cm{sup 2} FS, respectably. Discrepancies were reduced with increasing field size and MU. We predict a minimum of 100 frames is needed for reliable confirmation of delivered FS. Conclusion: Current discrepancies in Cherenkov field sizes are within a usable range to confirm treatment delivery in standard and respiratory gated clinical scenarios at MU levels appropriate to standard MLC position segments.« less
Zengel, James; Phan, Shannon I; Pickar, Adrian; Xu, Pei; He, Biao
2017-07-13
Mumps virus (MuV) causes acute infection in humans with characteristic swelling of the parotid gland. While vaccination has greatly reduced the incidence of MuV infection, there have been multiple large outbreaks of mumps virus (MuV) in highly vaccinated populations. The most common vaccine strain, Jeryl Lynn, belongs to genotype A, which is no longer a circulating genotype. We have developed two vaccine candidates that match the circulating genotypes in the United States (genotype G) and China (genotype F). We found that there was a significant decrease in the ability of the Jeryl Lynn vaccine to produce neutralizing antibody responses to non-matched viruses, when compared to either of our vaccine candidates. Our data suggests that an updated vaccine may allow for better immunity against the circulating MuV genotypes G and F. Copyright © 2017 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Han, C; Schultheiss, T
Purpose: In this study, we aim to evaluate the effect of dose grid size on the accuracy of calculated dose for small lesions in intracranial stereotactic radiosurgery (SRS), and to verify dose calculation accuracy with radiochromic film dosimetry. Methods: 15 intracranial lesions from previous SRS patients were retrospectively selected for this study. The planning target volume (PTV) ranged from 0.17 to 2.3 cm{sup 3}. A commercial treatment planning system was used to generate SRS plans using the volumetric modulated arc therapy (VMAT) technique using two arc fields. Two convolution-superposition-based dose calculation algorithms (Anisotropic Analytical Algorithm and Acuros XB algorithm) weremore » used to calculate volume dose distribution with dose grid size ranging from 1 mm to 3 mm with 0.5 mm step size. First, while the plan monitor units (MU) were kept constant, PTV dose variations were analyzed. Second, with 95% of the PTV covered by the prescription dose, variations of the plan MUs as a function of dose grid size were analyzed. Radiochomic films were used to compare the delivered dose and profile with the calculated dose distribution with different dose grid sizes. Results: The dose to the PTV, in terms of the mean dose, maximum, and minimum dose, showed steady decrease with increasing dose grid size using both algorithms. With 95% of the PTV covered by the prescription dose, the total MU increased with increasing dose grid size in most of the plans. Radiochromic film measurements showed better agreement with dose distributions calculated with 1-mm dose grid size. Conclusion: Dose grid size has significant impact on calculated dose distribution in intracranial SRS treatment planning with small target volumes. Using the default dose grid size could lead to under-estimation of delivered dose. A small dose grid size should be used to ensure calculation accuracy and agreement with QA measurements.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gray, T.J.; Richard, P.; Gealy, G.
1979-04-01
Thin solid Al targets ranging in thickness from approx. 1 to 30 ..mu..g/cm/sup 2/ were bombarded by /sup 16/O ions wih incident energies from 0.25 to 2.25 MeV/amu. The effects of target thickness on the measured Al K x-ray yield for ions incident without an initial K-shell vacancy were determined. Comparisons of the data for Al K x-ray production in vanishingly thin targets (and 29-..mu..g/cm/sup 2/ targets) were made to perturbed-stationary-state calculations (PSS) for O ions on Al targets. The PSS calculations contained corrections for Coulomb deflection and binding energy (PSS(CB)) and for Coulomb deflection, binding energy, and polarization (PSS(CBP)).more » Further, two different PSS calculation procedures were employed: calculations without radial cutoffs employed in the binding-energy contribution (PSS), and calculations with radial cutoffs employed in the binding-energy correction (NPSS). The PSS(CBP) calculations agree with the measured Al K x-ray production cross section for data taken in the limit of a vanishingly thin target. The NPSS(CBP) calculations agree with the data taken for a 29-..mu..g/cm/sup 2/ Al target. The latter agreement is fortuitous, as the increase observed in the measured target x-ray yield for the 29-..mu..g/cm/sup 2/ target, in comparison to the yield extracted as rhox ..-->.. 0 at each bombarding energy, is due to K-shell--to--K-shell charge exchange. Comparisons are made with previously published data for /sup 16/O ions incident on finite-thickness Al targets.« less
Rah, Jeong-Eun; Shin, Dongho; Oh, Do Hoon; Kim, Tae Hyun; Kim, Gwe-Ya
2014-09-01
To evaluate and improve the reliability of proton quality assurance (QA) processes and, to provide an optimal customized tolerance level using the statistical process control (SPC) methodology. The authors investigated the consistency check of dose per monitor unit (D/MU) and range in proton beams to see whether it was within the tolerance level of the daily QA process. This study analyzed the difference between the measured and calculated ranges along the central axis to improve the patient-specific QA process in proton beams by using process capability indices. The authors established a customized tolerance level of ±2% for D/MU and ±0.5 mm for beam range in the daily proton QA process. In the authors' analysis of the process capability indices, the patient-specific range measurements were capable of a specification limit of ±2% in clinical plans. SPC methodology is a useful tool for customizing the optimal QA tolerance levels and improving the quality of proton machine maintenance, treatment delivery, and ultimately patient safety.
NASA Astrophysics Data System (ADS)
Eshtiagh-Hosseini, H.; Aghabozorg, H.; Mirzaei, M.; Beyramabadi, S. A.; Eshghi, H.; Morsali, A.; Shokrollahi, A.; Aghaei, R.
2011-05-01
This paper reports the hydrothermal synthesis, experimental and theoretical studies of a novel cocrystal compound in the 2:1 stoichiometric ratio of 6-methyluracil (6mu) and dipicolinic acid (pydcH 2) formulated as [6mu] 2[pydcH 2] (1), for the first time. DFT calculations were performed to access the most possible geometry of the title cocrystal compound. All calculations were carried out with the B3LYP hybrid density functional level and 6-311+G(d,p) basis sets. The vibrational frequencies together with the 1H and 13C NMR chemical shifts have been calculated on the fully optimized geometry of 1. The theoretical results are in good agreement with the experimental and solution data. The theoretical, solution, and experimental (elemental analysis, mass spectrometry, FTIR, 1H and 13C NMR spectroscopies) results confirmed our proposed structure for 1 in the 2:1 stoichiometric ratio of 6mu and pydcH 2, respectively. The protonation and equilibrium constants of 6mu and pydcH 2 and constituent systems were determined by potentiometric studies and the corresponding distribution diagrams depicted.
Influence of vibration in the reactive scattering of D+MuH: The effect of dynamical bonding
Sáez-Rábanos, V.; Verdasco, J. E.; Aoiz, F. J.; Herrero, V. J.
2016-01-01
The dynamics of the D+MuH(υ=1) reaction has been investigated using time-independent quantum mechanical calculations. Total reaction cross sections and rate coefficients have been calculated for the two exit channels of the reaction leading respectively to DMu+H and DH+Mu. Over the 100-1000K temperature range investigated the rate coefficients for the DMu+H channel are of the order of 10−10 cm3 s−1 and those for the DH+Mu channel vary between 1·10−12−8·10−11 cm3 s−1. These results point to a virtually barrierless reaction for the DMu+H channel and to the presence of a comparatively small barrier for the DH+Mu channel and are consistent with the profiles of their respective collinear vibrationally adiabatic potentials (VAPs). The effective barrier in the VAP of the DH+Mu channel is located in the reactants valley and, consequently, translation is found to be more efficient than vibration for the promotion of the reaction over a large energy interval in the post threshold region. Below this barrier, the DH+Mu channel can be accessible through an indirect mechanism implying a crossing from the DMu+H pathway. The most salient feature found in the present study is revealed in the total reaction cross section for the DMu+H channel, which shows a sharp resonance caused by the presence of a deep well in the vibrationally adiabatic potential. This well has a dynamical origin, reminiscent of that found recently in the vibrationally bonded BrMuBr complex [Fleming et al. Angew. Chem. Int. Ed. 53, 1, 2014], and is due to the stabilizing effect of the light Mu atom oscillating between the heavier H and D isotopes and to the bond softening associated with vibrational excitation of MuH. PMID:27138743
Do family physicians electronic health records support meaningful use?
Peterson, Lars E; Blackburn, Brenna; Ivins, Douglas; Mitchell, Jason; Matson, Christine; Phillips, Robert L
2015-03-01
Spurred by government incentives, the use of electronic health records (EHRs) in the United States has increased; however, whether these EHRs have the functionality necessary to meet meaningful use (MU) criteria remains unknown. Our objective was to characterize family physician access to MU functionality when using a MU-certified EHR. Data were obtained from a convenience survey of family physicians accessing their American Board of Family Medicine online portfolio in 2011. A brief survey queried MU functionality. We used descriptive statistics to characterize the responses and bivariate statistics to test associations between MU and patient communication functions by presence of a MU-certified EHR. Out of 3855 respondents, 60% reported having an EHR that supports MU. Physicians with MU-certified EHRs were more likely than physicians without MU-certified EHRs to report patient registry activities (49.7% vs. 32.3%, p-value<0.01), tracking quality measures (74.1% vs. 56.4%, p-value<0.01), access to labs or consultation notes, and electronic prescribing; but electronic communication abilities were low regardless of EHR capabilities. Family physicians with MU-certified EHRs are more likely to report MU functionality; however, a sizeable minority does not report MU functions. Many family physicians with MU-certified EHRs may not successfully meet the successively stringent MU criteria and may face significant upgrade costs to do so. Cross sectional survey. Copyright © 2014 Elsevier Inc. All rights reserved.
Speedup computation of HD-sEMG signals using a motor unit-specific electrical source model.
Carriou, Vincent; Boudaoud, Sofiane; Laforet, Jeremy
2018-01-23
Nowadays, bio-reliable modeling of muscle contraction is becoming more accurate and complex. This increasing complexity induces a significant increase in computation time which prevents the possibility of using this model in certain applications and studies. Accordingly, the aim of this work is to significantly reduce the computation time of high-density surface electromyogram (HD-sEMG) generation. This will be done through a new model of motor unit (MU)-specific electrical source based on the fibers composing the MU. In order to assess the efficiency of this approach, we computed the normalized root mean square error (NRMSE) between several simulations on single generated MU action potential (MUAP) using the usual fiber electrical sources and the MU-specific electrical source. This NRMSE was computed for five different simulation sets wherein hundreds of MUAPs are generated and summed into HD-sEMG signals. The obtained results display less than 2% error on the generated signals compared to the same signals generated with fiber electrical sources. Moreover, the computation time of the HD-sEMG signal generation model is reduced to about 90% compared to the fiber electrical source model. Using this model with MU electrical sources, we can simulate HD-sEMG signals of a physiological muscle (hundreds of MU) in less than an hour on a classical workstation. Graphical Abstract Overview of the simulation of HD-sEMG signals using the fiber scale and the MU scale. Upscaling the electrical source to the MU scale reduces the computation time by 90% inducing only small deviation of the same simulated HD-sEMG signals.
$B$- and $D$-meson leptonic decay constants from four-flavor lattice QCD
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bazavov, A.; Bernard, C.; Brown, N.
We calculate the leptonic decay constants of heavy-light pseudoscalar mesons with charm and bottom quarks in lattice quantum chromodynamics on four-flavor QCD gauge-field configurations with dynamicalmore » $u$, $d$, $s$, and $c$ quarks. We analyze over twenty isospin-symmetric ensembles with six lattice spacings down to $$a\\approx 0.03$$~fm and several values of the light-quark mass down to the physical value $$\\frac{1}{2}(m_u+m_d)$$. We employ the highly-improved staggered-quark (HISQ) action for the sea and valence quarks; on the finest lattice spacings, discretization errors are sufficiently small that we can calculate the $B$-meson decay constants with the HISQ action for the first time directly at the physical $b$-quark mass. We obtain the most precise determinations to-date of the $D$- and $B$-meson decay constants and their ratios, $$f_{D^+} = 212.6 (0.5)$$~MeV, $$f_{D_s} = 249.8(0.4)$$~MeV, $$f_{D_s}/f_{D^+} = 1.1749(11)$$, $$f_{B^+} = 189.4(1.4)$$~MeV, $$f_{B_s} = 230.7(1.2)$$~MeV, $$f_{B_s}/f_{B^+} = 1.2180(49)$$, where the errors include statistical and all systematic uncertainties. Our results for the $B$-meson decay constants are three times more precise than the previous best lattice-QCD calculations, and bring the QCD errors in the Standard-Model predictions for the rare leptonic decays $$\\overline{\\mathcal{B}}(B_s \\to \\mu^+\\mu^-) = 3.65(11) \\times 10^{-9}$$, $$\\overline{\\mathcal{B}}(B^0 \\to \\mu^+\\mu^-) = 1.00(3) \\times 10^{-11}$$, and $$\\overline{\\mathcal{B}}(B^0 \\to \\mu^+\\mu^-)/\\overline{\\mathcal{B}}(B_s \\to \\mu^+\\mu^-) = 0.00264(7)$$ to well below other sources of uncertainty. As a byproduct of our analysis, we also update our previously published results for the light-quark-mass ratios and the scale-setting quantities $$f_{p4s}$$, $$M_{p4s}$$, and $$R_{p4s}$$. We obtain the most precise lattice-QCD determination to date of the ratio $$f_{K^+}/f_{\\pi^+} = 1.1950(^{+15}_{-22})$$~MeV.« less
Dressler, Dirk; Adib Saberi, Fereshte
2017-01-01
AbobotulinumtoxinA (Dysport®) was distributed for many years in vials containing 500MU (D500). Recently a new 300MU vial (D300) was additionally introduced (introduction). We wanted to explore whether more differentiated package sizes allow for more economic use of Dysport® in a large neurological botulinum toxin (BT) outpatient clinic. The study followed a retrospective chart review design based on our digital BT therapy data bank. All patients receiving Dysport® exclusively in a constant dose during the observation period (introduction ± 7 months) were included. Economic calculations are based on Dysport® prices as officially advertised in Germany. Sharing of vials between patients was not allowed. Altogether 83 patients (51 with dystonia, 25 with spasticity, 3 with hemifacial spasm, 4 with other diagnoses) were included in this study. The total amount of BT used before and after introduction was 102525MU, the amount prescribed 138000MU and 116300MU (-21700MU, -15.7%), the costs €146103 and €125250 (-€ 20853, -14.3%). The price for D500 before and after introduction was €529.36, for D300 €339.71. The D500 price for 1MU before and after introduction is €1.0587, the D300 price for 1MU €1.1324 (+ €0.073, +7.0% against D500). More flexible packaging reduces drug costs for BT therapy considerably. Introducing smaller packaging sizes is technically possible and should be encouraged. Extra costs for registration and logistics are moderate. Further cost reductions may be possible by introduction of even smaller packaging sizes. They can be calculated based on our model.
NASA Astrophysics Data System (ADS)
Shin, Henry; Suresh, Nina L.; Zev Rymer, William; Hu, Xiaogang
2018-02-01
Objective. Chronic muscle weakness impacts the majority of individuals after a stroke. The origins of this hemiparesis is multifaceted, and an altered spinal control of the motor unit (MU) pool can lead to muscle weakness. However, the relative contribution of different MU recruitment and discharge organization is not well understood. In this study, we sought to examine these different effects by utilizing a MU simulation with variations set to mimic the changes of MU control in stroke. Approach. Using a well-established model of the MU pool, this study quantified the changes in force output caused by changes in MU recruitment range and recruitment order, as well as MU firing rate organization at the population level. We additionally expanded the original model to include a fatigue component, which variably decreased the output force with increasing length of contraction. Differences in the force output at both the peak and fatigued time points across different excitation levels were quantified and compared across different sets of MU parameters. Main results. Across the different simulation parameters, we found that the main driving factor of the reduced force output was due to the compressed range of MU recruitment. Recruitment compression caused a decrease in total force across all excitation levels. Additionally, a compression of the range of MU firing rates also demonstrated a decrease in the force output mainly at the higher excitation levels. Lastly, changes to the recruitment order of MUs appeared to minimally impact the force output. Significance. We found that altered control of MUs alone, as simulated in this study, can lead to a substantial reduction in muscle force generation in stroke survivors. These findings may provide valuable insight for both clinicians and researchers in prescribing and developing different types of therapies for the rehabilitation and restoration of lost strength after stroke.
Characteristics of flattening filter free beams at low monitor unit settings.
Akino, Yuichi; Ota, Seiichi; Inoue, Shinichi; Mizuno, Hirokazu; Sumida, Iori; Yoshioka, Yasuo; Isohashi, Fumiaki; Ogawa, Kazuhiko
2013-11-01
Newer linear accelerators (linacs) have been equipped to deliver flattening filter free (FFF) beams. When FFF beams are used for step-and-shoot intensity-modulated radiotherapy (IMRT), the stability of delivery of small numbers of monitor units (MU) is important. The authors developed automatic measurement techniques to evaluate the stability of the dose profile, dose linearity, and consistency. Here, the authors report the performance of the Artiste™ accelerator (Siemens, Erlangen, Germany) in delivering low-MU FFF beams. A 6 MV flattened beam (6X) with 300 MU/min dose rate and FFF beams of 7 (7XU) and 11 MV (11XU), each with a 500 MU/min dose rate, were measured at 1, 2, 3, 5, 8, 10, and 20 MU settings. For the 2000 MU/min dose rate, the 7 (7XUH) and 11 MV (11XUH) beams were set at 10, 15, 20, 25, and 30 MU because of the limits of the minimum MU settings. Beams with 20 × 20 and 10 × 10 cm(2) field sizes were alternately measured ten times in intensity modulated (IM) mode, with which Siemens linacs regulate beam delivery for step-and-shoot IMRT. The in- and crossplane beam profiles were measured using a Profiler™ Model 1170 (Sun Nuclear Corporation, Melbourne, FL) in multiframe mode. The frames of 20 × 20 cm(2) beams were identified at the off-axis profile. The 6X beam profile was normalized at the central axis. The 7 and 11 MV FFF beam profiles were rescaled to set the dose at the central axis at 145% and 170%, respectively. Point doses were also measured using a Farmer-type ionization chamber and water-equivalent solid phantom to evaluate the linearity and consistency of low-MU beam delivery. The values displayed on the electrometer were recognized with a USB-type camera and read with open-source optical character recognition software. The symmetry measurements of the 6X, 7XU, and 11XU beam profiles were better than 2% for beams ≥ 2 MU and improved with increasing MU. The variations in flatness of FFF beams ≥ 2 MU were ± 5%. The standard deviation of the symmetry and flatness also decreased with increasing MU. The linearity of the 6X beam was ± 1% and ± 2% for the beams of ≥ 5 and ≥ 3 MU, respectively. The 7XU and 11XU beams of ≥ 2 MU showed linearity with ± 2% except the 7XU beam of 8 MU (+2.9%). The profiles of the FFF beams with 2000 and 500 MU/min dose rate were similar. The characteristics of low-MU beams delivered in IM mode were evaluated using an automatic measurement system developed in this study. The authors demonstrated that the profiles of FFF beams of the Artiste™ linac were highly stable, even at low MU. The linearity of dose output was also stable for beams ≥ 2 MU.
NASA Technical Reports Server (NTRS)
Mikouchi, T.; Takenouchi, A.; Zolensky, M. E.; Hoffmann, V. H.
2018-01-01
Almahata Sitta meteorites are unique polymict breccia, comprising of many different meteorite groups as individual fragments dominated by ureilite lithologies and are considered to be recovered fragments of the asteroid 2008TC3. Recently, two unusual Almahata Sitta samples (MS-MU-011 and MS-MU-012) have been reported that show close petrogenetic relationships to ureilites. MS-MU-011 is a trachyandesite mainly composed of feldspar (plagioclase and anorthoclase) and pyroxene (pigeonite and augite) having ureilitic oxygen isotopic ratios. MS-MU-012 is the first ureilite example (unbrecciated) containing primary plagioclase crystals. The findings of these two rock types are important to better understand formation conditions of ureilites and the evolution of their parent body(s). In this abstract we discuss formation conditions of these ureilite-related rocks using redox state estimate by Fe valence states of plagioclase and olivine cooling rate calculations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beckman, D.E.
The structures of 0-0-dimethyl-0-(3,5,6-trichloro-2-pyridyl) phosphorothioate (Dowco 214) and dicarbonylbis(eta-cyclopentadienyl)-..mu..-carbonyl-..mu..-thiocarbonyldiiron have been solved by single crystal x-ray diffraction and use of a modified Patterson superposition technique that uses two multiple vectors to define a structural parallelogram. This method results in a simpler and more accurate shift vector position determination and a general improvement in map clarity. Dowco 214 crystallizes in the space group P/sub 1//sup -/ with a = 11.598(2) A, b = 13.619(3) A, c = 8.281(1) A, ..cap alpha.. = 94.65(1)/sup 0/, ..beta.. = 94.87(2)/sup 0/, ..gamma.. = 79.97(2)/sup 0/ and four molecules per cell (two per asymmetric unit).more » A CNDO II calculation was performed and partial charge densities assigned. The molecule contains distances between positively charged centers that correspond well to the reported anionic-esteratic distance (a possible reaction variable) in AChE. Additional reaction variables are discussed. Cp/sub 2/Fe/sub 2/(CO)/sub 3/CS crystallizes in the space group P2/sub 1//c with a = 14.508(8) A, b = 13.618(5) A, c = 15.193(7) A, ..beta.. = 110.50(6)/sup 0/ and eight molecules per unit cell (two per asymmetric unit). The compound contains both a carbonyl and thiocarbonyl bridge and ..pi..-bonded cyclopentadienyl rings that are cis to one another. The iron--iron bond length is intermediate to that of its carbonyl and thiocarbonyl analogs.« less
Hawkins, Robert C; Badrick, Tony
2015-08-01
In this study we aimed to compare the reporting unit size used by Australian laboratories for routine chemistry and haematology tests to the unit size used by learned authorities and in standard laboratory textbooks and to the justified unit size based on measurement uncertainty (MU) estimates from quality assurance program data. MU was determined from Royal College of Pathologists of Australasia (RCPA) - Australasian Association of Clinical Biochemists (AACB) and RCPA Haematology Quality Assurance Program survey reports. The reporting unit size implicitly suggested in authoritative textbooks, the RCPA Manual, and the General Serum Chemistry program itself was noted. We also used published data on Australian laboratory practices.The best performing laboratories could justify their chemistry unit size for 55% of analytes while comparable figures for the 50% and 90% laboratories were 14% and 8%, respectively. Reporting unit size was justifiable for all laboratories for red cell count, >50% for haemoglobin but only the top 10% for haematocrit. Few, if any, could justify their mean cell volume (MCV) and mean cell haemoglobin concentration (MCHC) reporting unit sizes.The reporting unit size used by many laboratories is not justified by present analytical performance. Using MU estimates to determine the reporting interval for quantitative laboratory results ensures reporting practices match local analytical performance and recognises the inherent error of the measurement process.
Cui, Ming; Xu, Lili; Wang, Huimin; Ju, Shaoqing; Xu, Shuizhu; Jing, Rongrong
2017-12-01
Measurement uncertainty (MU) is a metrological concept, which can be used for objectively estimating the quality of test results in medical laboratories. The Nordtest guide recommends an approach that uses both internal quality control (IQC) and external quality assessment (EQA) data to evaluate the MU. Bootstrap resampling is employed to simulate the unknown distribution based on the mathematical statistics method using an existing small sample of data, where the aim is to transform the small sample into a large sample. However, there have been no reports of the utilization of this method in medical laboratories. Thus, this study applied the Nordtest guide approach based on bootstrap resampling for estimating the MU. We estimated the MU for the white blood cell (WBC) count, red blood cell (RBC) count, hemoglobin (Hb), and platelets (Plt). First, we used 6months of IQC data and 12months of EQA data to calculate the MU according to the Nordtest method. Second, we combined the Nordtest method and bootstrap resampling with the quality control data and calculated the MU using MATLAB software. We then compared the MU results obtained using the two approaches. The expanded uncertainty results determined for WBC, RBC, Hb, and Plt using the bootstrap resampling method were 4.39%, 2.43%, 3.04%, and 5.92%, respectively, and 4.38%, 2.42%, 3.02%, and 6.00% with the existing quality control data (U [k=2]). For WBC, RBC, Hb, and Plt, the differences between the results obtained using the two methods were lower than 1.33%. The expanded uncertainty values were all less than the target uncertainties. The bootstrap resampling method allows the statistical analysis of the MU. Combining the Nordtest method and bootstrap resampling is considered a suitable alternative method for estimating the MU. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Yoshitake, Yasuhide; Shinohara, Minoru
2013-11-01
Common drive to a motor unit (MU) pool manifests as low-frequency oscillations in MU discharge rate, producing fluctuations in muscle force. The aim of the study was to examine the temporal correlation between instantaneous MU discharge rate and rectified EMG in low frequencies. Additionally, we attempted to examine whether there is a temporal correlation between the low-frequency oscillations in MU discharge rate and the first derivative of force (dF/dt). Healthy young subjects produced steady submaximal force with their right finger as a single task or while maintaining a pinch-grip force with the left hand as a dual task. Surface EMG and fine-wire MU potentials were recorded from the first dorsal interosseous muscle in the right hand. Surface EMG was band-pass filtered (5-1,000 Hz) and full-wave rectified. Rectified surface EMG and the instantaneous discharge rate of MUs were smoothed by a Hann-window of 400 ms duration (equivalent to 2 Hz low-pass filtering). In each of the identified MUs, the smoothed MU discharge rate was positively correlated with the rectified-and-smoothed EMG as confirmed by the distinct peak in cross-correlation function with greater values in the dual task compared with the single task. Additionally, the smoothed MU discharge rate was temporally correlated with dF/dt more than with force and with rectified-and-smoothed EMG. The results indicated that the low-frequency component of rectified surface EMG and the first derivative of force provide temporal information on the low-frequency oscillations in the MU discharge rate.
Hu, Xiaogang; Suresh, Aneesha K; Rymer, William Z; Suresh, Nina L
2015-12-01
The advancement of surface electromyogram (sEMG) recording and signal processing techniques has allowed us to characterize the recruitment properties of a substantial population of motor units (MUs) non-invasively. Here we seek to determine whether MU recruitment properties are modified in paretic muscles of hemispheric stroke survivors. Using an advanced EMG sensor array, we recorded sEMG during isometric contractions of the first dorsal interosseous muscle over a range of contraction levels, from 20% to 60% of maximum, in both paretic and contralateral muscles of stroke survivors. Using MU decomposition techniques, MU action potential amplitudes and recruitment thresholds were derived for simultaneously activated MUs in each isometric contraction. Our results show a significant disruption of recruitment organization in paretic muscles, in that the size principle describing recruitment rank order was materially distorted. MUs were recruited over a very narrow force range with increasing force output, generating a strong clustering effect, when referenced to recruitment force magnitude. Such disturbances in MU properties also correlated well with the impairment of voluntary force generation. Our findings provide direct evidence regarding MU recruitment modifications in paretic muscles of stroke survivors, and suggest that these modifications may contribute to weakness for voluntary contractions.
Lei, Yuming; Suresh, Nina L; Rymer, William Z; Hu, Xiaogang
2018-01-01
Muscle force generation involves recruitment and firing rate modulation of motor units (MUs). The control of MUs in producing multidirectional forces remains unclear. We studied MU recruitment and firing properties, recorded from the first dorsal interosseous muscle, for 3 different directions of contraction: abduction; abduction/flexion combination; and flexion. MUs were recruited systematically at higher threshold force during flexion. Larger MUs were recruited and firing rates of MUs were lower during abduction. There was an orderly recruitment of MUs according to MU size regardless of contraction direction, obeying the "size principle." Firing rates of earlier-recruited MUs were consistently higher than later-recruited MUs, affirming the "onion-skin" property. Our findings suggest that the size principle and onion-skin organization together provide a general description of MU recruitment patterns and firing properties. The directional alternations of MU control properties likely reflect changes in neural drive to the muscle. Muscle Nerve 57: E85-E93, 2018. © 2017 Wiley Periodicals, Inc.
Selective fatigue of fast motor units after electrically elicited muscle contractions.
Hamada, Taku; Kimura, Tetsuya; Moritani, Toshio
2004-10-01
The aim of the present study was to elucidate the electrophysiological manifestations of selective fast motor unit (MU) activation by electrical stimulation (ES) of knee extensor muscles. In six male subjects, test contraction measurement at 40% maximal voluntary contraction (MVC) was performed before and at every 5 min (5, 10, 15 and 20 min) during 20-min low intensity intermittent exercise of either ES or voluntary contractions (VC) at 10% MVC (5-s isometric contraction and 5-s rest cycles). Both isolated intramuscular MU spikes obtained from three sets of bipolar fine-wire electrodes and surface electromyogram (EMG) were simultaneously recorded and were analyzed by means of a computer-aided intramuscular spike amplitude-frequency analysis and frequency power spectral analysis, respectively. Results indicated that mean MU spike amplitude, particularly those MUs with relatively large amplitude, was significantly reduced while those MUs with small spike amplitude increased their firing rate during the 40% MVC test contraction after the ES. This was accompanied by the increased amplitude of surface EMG (rmsEMG). However, no such significant changes in the intramuscular and surface EMGs were observed after VC. These findings indicated differential MU activation patterns in terms of MU recruitment and rate coding characteristics during ES and VC, respectively. Our data strongly suggest the possibility of "an inverse size principle" of MU recruitment during ES.
Hughes, Michael J; Mercier, Hélène P A; Schrobilgen, Gary J
2010-04-05
Stoichiometric amounts of XeF(6) and (OsO(3)F(2))(infinity) react at 25-50 degrees C to form salts of the known XeF(5)(+) and Xe(2)F(11)(+) cations, namely, [XeF(5)][mu-F(OsO(3)F(2))(2)], [XeF(5)][OsO(3)F(3)], and [Xe(2)F(11)][OsO(3)F(3)]. Although XeF(6) is oxophilic toward a number of transition metal and main-group oxides and oxide fluorides, fluoride/oxide metathesis was not observed. The series provides the first examples of noble-gas cations that are stabilized by metal oxide fluoride anions and the first example of a mu-F(OsO(3)F(2))(2)(-) salt. Both [XeF(5)][mu-F(OsO(3)F(2))(2)] and [Xe(2)F(11)][OsO(3)F(3)] are orange solids at room temperature. The [XeF(5)][OsO(3)F(3)] salt is an orange liquid at room temperature that solidifies at 5-0 degrees C. When the salts are heated at 50 degrees C under 1 atm of N(2) for more than 2 h, significant XeF(6) loss occurs. The X-ray crystal structures (-173 degrees C) show that the salts exist as discrete ion pairs and that the osmium coordination spheres in OsO(3)F(3)(-) and mu-F(OsO(3)F(2))(2)(-) are pseudo-octahedral OsO(3)F(3)-units having facial arrangements of oxygen and fluorine atoms. The mu-F(OsO(3)F(2))(2)(-) anion is comprised of two symmetry-related OsO(3)F(2)-groups that are fluorine-bridged to one another. Ion pairing results from secondary bonding interactions between the fluorine/oxygen atoms of the anions and the xenon atom of the cation, with the Xe...F/O contacts occurring opposite the axial fluorine and from beneath the equatorial XeF(4)-planes of the XeF(5)(+) and Xe(2)F(11)(+) cations so as to avoid the free valence electron lone pairs of the xenon atoms. The xenon atoms of [XeF(5)][mu-F(OsO(3)F(2))(2)] and [Xe(2)F(11)][OsO(3)F(3)] are nine-coordinate and the xenon atom of [XeF(5)][OsO(3)F(3)] is eight-coordinate. Quantum-chemical calculations at SVWN and B3LYP levels of theory were used to obtain the gas-phase geometries, vibrational frequencies, and NBO bond orders, valencies, and NPA charges of the ion pairs, [Xe(2)F(11)][OsO(3)F(3)], [XeF(5)][OsO(3)F(3)], and [XeF(5)][mu-F(OsO(3)F(2))(2)], as well as those of the free ions, Xe(2)F(11)(+), XeF(5)(+), OsO(3)F(3)(-), and mu-F(OsO(3)F(2))(2)(-). The Raman spectra (-150 degrees C) of the salts have been assigned based on the ion pairs observed in the crystal structures and the calculated vibrational frequencies and intensities of the gas-phase ion pairs.
Immunogenicity of Novel Mumps Vaccine Candidates Generated by Genetic Modification
Xu, Pei; Chen, Zhenhai; Phan, Shannon; Pickar, Adrian
2014-01-01
Mumps is a highly contagious human disease, characterized by lateral or bilateral nonsuppurative swelling of the parotid glands and neurological complications that can result in aseptic meningitis or encephalitis. A mumps vaccination program implemented since the 1960s reduced mumps incidence by more than 99% and kept the mumps case numbers as low as hundreds of cases per year in the United States before 2006. However, a large mumps outbreak occurred in vaccinated populations in 2006 and again in 2009 in the United States, raising concerns about the efficacy of the vaccination program. Previously, we have shown that clinical isolate-based recombinant mumps viruses lacking expression of either the V protein (rMuVΔV) or the SH protein (rMuVΔSH) are attenuated in a neurovirulence test using newborn rat brains (P. Xu et al., Virology 417:126–136, 2011, http://dx.doi.org/10.1016/j.virol.2011.05.003; P. Xu et al., J. Virol. 86:1768–1776, 2012, http://dx.doi.org/10.1128/JVI.06019-11) and may be good candidates for vaccine development. In this study, we examined immunity induced by rMuVΔSH and rMuVΔV in mice. Furthermore, we generated recombinant mumps viruses lacking expression of both the V protein and the SH protein (rMuVΔSHΔV). Analysis of rMuVΔSHΔV indicated that it was stable in tissue culture cell lines. Importantly, rMuVΔSHΔV was immunogenic in mice, indicating that it is a promising candidate for mumps vaccine development. PMID:24352450
Immunogenicity of novel mumps vaccine candidates generated by genetic modification.
Xu, Pei; Chen, Zhenhai; Phan, Shannon; Pickar, Adrian; He, Biao
2014-03-01
Mumps is a highly contagious human disease, characterized by lateral or bilateral nonsuppurative swelling of the parotid glands and neurological complications that can result in aseptic meningitis or encephalitis. A mumps vaccination program implemented since the 1960s reduced mumps incidence by more than 99% and kept the mumps case numbers as low as hundreds of cases per year in the United States before 2006. However, a large mumps outbreak occurred in vaccinated populations in 2006 and again in 2009 in the United States, raising concerns about the efficacy of the vaccination program. Previously, we have shown that clinical isolate-based recombinant mumps viruses lacking expression of either the V protein (rMuVΔV) or the SH protein (rMuVΔSH) are attenuated in a neurovirulence test using newborn rat brains (P. Xu et al., Virology 417:126-136, 2011, http://dx.doi.org/10.1016/j.virol.2011.05.003; P. Xu et al., J. Virol. 86:1768-1776, 2012, http://dx.doi.org/10.1128/JVI.06019-11) and may be good candidates for vaccine development. In this study, we examined immunity induced by rMuVΔSH and rMuVΔV in mice. Furthermore, we generated recombinant mumps viruses lacking expression of both the V protein and the SH protein (rMuVΔSHΔV). Analysis of rMuVΔSHΔV indicated that it was stable in tissue culture cell lines. Importantly, rMuVΔSHΔV was immunogenic in mice, indicating that it is a promising candidate for mumps vaccine development.
Action potential amplitude as a noninvasive indicator of motor unit-specific hypertrophy.
Pope, Zachary K; Hester, Garrett M; Benik, Franklin M; DeFreitas, Jason M
2016-05-01
Skeletal muscle fibers hypertrophy in response to strength training, with type II fibers generally demonstrating the greatest plasticity in regards to cross-sectional area (CSA). However, assessing fiber type-specific CSA in humans requires invasive muscle biopsies. With advancements in the decomposition of surface electromyographic (sEMG) signals recorded using multichannel electrode arrays, the firing properties of individual motor units (MUs) can now be detected noninvasively. Since action potential amplitude (APSIZE) has a documented relationship with muscle fiber size, as well as with its parent MU's recruitment threshold (RT) force, our purpose was to examine if MU APSIZE, as a function of its RT (i.e., the size principle), could potentially be used as a longitudinal indicator of MU-specific hypertrophy. By decomposing the sEMG signals from the vastus lateralis muscle of 10 subjects during maximal voluntary knee extensions, we noninvasively assessed the relationship between MU APSIZE and RT before and immediately after an 8-wk strength training intervention. In addition to significant increases in muscle size and strength (P < 0.02), our data show that training elicited an increase in MU APSIZE of high-threshold MUs. Additionally, a large portion of the variance (83.6%) in the change in each individual's relationship between MU APSIZE and RT was explained by training-induced changes in whole muscle CSA (obtained via ultrasonography). Our findings suggest that the noninvasive, electrophysiological assessment of longitudinal changes to MU APSIZE appears to reflect hypertrophy specific to MUs across the RT continuum. Copyright © 2016 the American Physiological Society.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, H; Guerrero, M; Chen, S
Purpose: The TG-71 report was published in 2014 to present standardized methodologies for MU calculations and determination of dosimetric quantities. This work explores the clinical implementation of a TG71-based electron MU calculation algorithm and compares it with a recently released commercial secondary calculation program–Mobius3D (Mobius Medical System, LP). Methods: TG-71 electron dosimetry data were acquired, and MU calculations were performed based on the recently published TG-71 report. The formalism in the report for extended SSD using air-gap corrections was used. The dosimetric quantities, such PDD, output factor, and f-air factors were incorporated into an organized databook that facilitates data accessmore » and subsequent computation. The Mobius3D program utilizes a pencil beam redefinition algorithm. To verify the accuracy of calculations, five customized rectangular cutouts of different sizes–6×12, 4×12, 6×8, 4×8, 3×6 cm{sup 2}–were made. Calculations were compared to each other and to point dose measurements for electron beams of energy 6, 9, 12, 16, 20 MeV. Each calculation / measurement point was at the depth of maximum dose for each cutout in a 10×10 cm{sup 2} or 15×15cm{sup 2} applicator with SSDs 100cm and 110cm. Validation measurements were made with a CC04 ion chamber in a solid water phantom for electron beams of energy 9 and 16 MeV. Results: Differences between the TG-71 and the commercial system relative to measurements were within 3% for most combinations of electron energy, cutout size, and SSD. A 5.6% difference between the two calculation methods was found only for the 6MeV electron beam with 3×6 cm{sup 2}cutout in the 10×10{sup 2}cm applicator at 110cm SSD. Both the TG-71 and the commercial calculations show good consistency with chamber measurements: for 5 cutouts, <1% difference for 100cm SSD, and 0.5–2.7% for 110cm SSD. Conclusions: Based on comparisons with measurements, a TG71-based computation method and a Mobius3D program produce reasonably accurate MU calculations for electron-beam therapy.« less
Telle, J.M.
1984-05-01
Apparatus and method for generating continuous wave 16 ..mu..m laser radiation using gaseous CF/sub 4/. Laser radiation at 16 ..mu..m has been observed in a cooled static cell containing low pressure CF/sub 4/ optically pumped by an approximately 3 W output power c-w CO/sub 2/ laser. The laser cavity employed was a multiple-pass off-axis-path two spherical mirror ring resonator. Unidirectional CF/sub 4/ laser output power at 615 cm/sup -1/ exceeded 2 mW. Computer calculations indicate that for modest pump powers of about 40 W, approximately 1 W of emitted laser radiation at 16 ..mu..m might be obtained.
Apparatus and method for generating continuous wave 16 .mu.m laser radiation using gaseous CF.sub.4
Telle, John M.
1986-01-01
Apparatus and method for generating continuous wave 16 .mu.m laser radiation using gaseous CF.sub.4. Laser radiation at 16 .mu.m has been observed in a cooled static cell containing low pressure CF.sub.4 optically pumped by an approximately 3 W output power cw CO.sub.2 laser. The laser cavity employed was a multiple-pass off-axis-path two spherical mirror ring resonator. Unidirectional CF.sub.4 laser output power at 615 cm.sup.-1 exceeded 2 mW. Computer calculations indicate that for modest pump powers of about 40 W, approximately 1 W of emitted laser radiation at 16 .mu.m might be obtained.
van Dijk, J P; Eiglsperger, U; Hellmann, D; Giannakopoulos, N N; McGill, K C; Schindler, H J; Lapatki, B G
2016-09-01
To study motor unit activity in the medio-lateral extension of the masseter using an adapted scanning EMG technique that allows studying the territories of multiple motor units (MUs) in one scan. We studied the m. masseter of 10 healthy volunteers in whom two scans were performed. A monopolar scanning needle and two pairs of fine-wire electrodes were inserted into the belly of the muscle. The signals of the fine wire electrodes were decomposed into the contribution of single MUs and used as a trigger for the scanning needle. In this manner multiple MU territory scans were obtained simultaneously. We determined 161 MU territories. The maximum number of territories obtained in one scan was 15. The median territory size was 4.0mm. Larger and smaller MU territories were found throughout the muscle. The presented technique showed its feasibility in obtaining multiple MU territories in one scan. MUs were active throughout the depth of the muscle. The distribution of electrical and anatomical size of MUs substantiates the heterogeneous distribution of MUs throughout the muscle volume. This distributed activity may be of functional significance for the stabilization of the muscle during force generation. Copyright © 2016 International Federation of Clinical Neurophysiology. All rights reserved.
Voityuk, Alexander A
2006-02-14
Comparison of donor-acceptor electronic couplings calculated within two-state and three-state models suggests that the two-state treatment can provide unreliable estimates of V(da) because of neglecting the multistate effects. We show that in most cases accurate values of the electronic coupling in a pi stack, where donor and acceptor are separated by a bridging unit, can be obtained as V(da) = (E(2)-E(1))mu(12)R(da) + (2E(3)-E(1)-E(2))2mu(13)mu(23)R(da) (2), where E(1), E(2), and E(3) are adiabatic energies of the ground, charge-transfer, and bridge states, respectively, mu(ij) is the transition dipole moments between the states i and j, and R(da) is the distance between the planes of donor and acceptor. In this expression based on the generalized Mulliken-Hush approach, the first term corresponds to the coupling derived within a two-state model, whereas the second term is the superexchange correction accounting for the bridge effect. The formula is extended to bridges consisting of several subunits. The influence of the donor-acceptor energy mismatch on the excess charge distribution, adiabatic dipole and transition moments, and electronic couplings is examined. A diagnostic is developed to determine whether the two-state approach can be applied. Based on numerical results, we showed that the superexchange correction considerably improves estimates of the donor-acceptor coupling derived within a two-state approach. In most cases when the two-state scheme fails, the formula gives reliable results which are in good agreement (within 5%) with the data of the three-state generalized Mulliken-Hush model.
Mixed-valent [FeIV(mu-O)(mu-carboxylato)2FeIII]3+ core.
Slep, Leonardo D; Mijovilovich, Ana; Meyer-Klaucke, Wolfram; Weyhermüller, Thomas; Bill, Eckhard; Bothe, Eberhard; Neese, Frank; Wieghardt, Karl
2003-12-17
The symmetrically ligated complexes 1, 2, and 3 with a (mu-oxo)bis(mu-acetato)diferric core can be one-electron oxidized electrochemically or chemically with aminyl radical cations [*NR3][SbCl6] in acetonitrile yielding complexes which contain the mixed-valent [(mu-oxo)bis(mu-acetato)iron(IV)iron(III)]3+ core: [([9]aneN3)(2FeIII2)(mu-O)(mu-CH3CO2)2](ClO4)2 (1(ClO4)2), [(Me3[9]aneN3)(2FeIII2)(mu-O)(mu-CH3CO2)2](PF6)2 (2(PF6)(2)), and [(tpb)(2FeIII2)(mu-O)(mu-CH3CO2)2] (3) where ([9]aneN3) is the neutral triamine 1,4,7-triazacyclononane and (Me3[9]aneN3) is its tris-N-methylated derivative, and (tpb)(-) is the monoanion trispyrazolylborate. The asymmetrically ligated complex [(Me3[9]aneN3)FeIII(mu-O)(mu-CH3CO2)2FeIII(tpb)](PF6) (4(PF6)) and its one-electron oxidized form [4ox]2+ have also been prepared. Finally, the known heterodinuclear species [(Me3[9]aneN3)CrIII(mu-O)(mu-CH3CO2)2Fe([9]aneN3)](PF6)2 (5(PF6)(2)) can also be one-electron oxidized yielding [5ox]3+ containing an iron(IV) ion. The structure of 4(PF6).0.5CH3CN.0.25(C2H5)2O has been determined by X-ray crystallography and that of [5ox]2+ by Fe K-edge EXAFS-spectroscopy (Fe(IV)-O(oxo): 1.69(1) A; Fe(IV)-O(carboxylato) 1.93(3) A, Fe(IV)-N 2.00(2) A) contrasting the data for 5 (Fe(III)-O(oxo) 1.80 A; Fe(III)-O(carboxylato) 2.05 A, Fe-N 2.20 A). [5ox]2+ has an St = 1/2 ground state whereas all complexes containing the mixed-valent [FeIV(mu-O)(mu-CH3CO2)2FeIII]3+ core have an St = 3/2 ground state. Mössbauer spectra of the oxidized forms of complexes clearly show the presence of low spin FeIV ions (isomer shift approximately 0.02 mm s(-1), quadrupole splitting approximately 1.4 mm s(-1) at 80 K), whereas the high spin FeIII ion exhibits delta approximately 0.46 mm s(-1) and DeltaE(Q) approximately 0.5 mm s(-1). Mössbauer, EPR spectral and structural parameters have been calculated by density functional theoretical methods at the BP86 and B3LYP levels. The exchange coupling constant, J, for diiron complexes with the mixed-valent FeIV-FeIII core (H = -2J S1.S2; S(1) = 5/2; S2 = 1) has been calculated to be -88 cm(-1) (intramolecular antiferromagnetic coupling) and for the reduced diferric form of -75 cm(-1) in reasonable agreement with experiment (J = -120 cm(-1)).
Negro, Francesco; Farina, Dario
2017-01-01
We investigated whether correlation measures derived from pairs of motor unit (MU) spike trains are reliable indicators of the degree of common synaptic input to motor neurons. Several 50-s isometric contractions of the biceps brachii muscle were performed at different target forces ranging from 10 to 30% of the maximal voluntary contraction relying on force feedback. Forty-eight pairs of MUs were examined at various force levels. Motor unit synchrony was assessed by cross-correlation analysis using three indexes: the output correlation as the peak of the cross-histogram (ρ) and the number of synchronous spikes per second (CIS) and per trigger (E). Individual analysis of MU pairs revealed that ρ, CIS, and E were most often positively associated with discharge rate (87, 85, and 76% of the MU pairs, respectively) and negatively with interspike interval variability (69, 65, and 62% of the MU pairs, respectively). Moreover, the behavior of synchronization indexes with discharge rate (and interspike interval variability) varied greatly among the MU pairs. These results were consistent with theoretical predictions, which showed that the output correlation between pairs of spike trains depends on the statistics of the input current and motor neuron intrinsic properties that differ for different motor neuron pairs. In conclusion, the synchronization between MU firing trains is necessarily caused by the (functional) common input to motor neurons, but it is not possible to infer the degree of shared common input to a pair of motor neurons on the basis of correlation measures of their output spike trains. NEW & NOTEWORTHY The strength of correlation between output spike trains is only poorly associated with the degree of common input to the population of motor neurons. The synchronization between motor unit firing trains is necessarily caused by the (functional) common input to motor neurons, but it is not possible to infer the degree of shared common input to a pair of motor neurons on the basis of correlation measures of their output spike trains. PMID:28100652
NASA Astrophysics Data System (ADS)
Hu, Xiaogang; Suresh, Aneesha K.; Rymer, William Z.; Suresh, Nina L.
2015-12-01
Objective. The advancement of surface electromyogram (sEMG) recording and signal processing techniques has allowed us to characterize the recruitment properties of a substantial population of motor units (MUs) non-invasively. Here we seek to determine whether MU recruitment properties are modified in paretic muscles of hemispheric stroke survivors. Approach. Using an advanced EMG sensor array, we recorded sEMG during isometric contractions of the first dorsal interosseous muscle over a range of contraction levels, from 20% to 60% of maximum, in both paretic and contralateral muscles of stroke survivors. Using MU decomposition techniques, MU action potential amplitudes and recruitment thresholds were derived for simultaneously activated MUs in each isometric contraction. Main results. Our results show a significant disruption of recruitment organization in paretic muscles, in that the size principle describing recruitment rank order was materially distorted. MUs were recruited over a very narrow force range with increasing force output, generating a strong clustering effect, when referenced to recruitment force magnitude. Such disturbances in MU properties also correlated well with the impairment of voluntary force generation. Significance. Our findings provide direct evidence regarding MU recruitment modifications in paretic muscles of stroke survivors, and suggest that these modifications may contribute to weakness for voluntary contractions.
Triplet firing origin in human motor units: emerging hypotheses.
Kudina, Lydia P; Andreeva, Regina E
2016-03-01
A specific feature of motor unit (MU) firing behaviour is rhythmic trains of single discharges at low rate resulting from the prolonged motoneuronal afterhyperpolarization. However, some MUs exhibit occasional doublets with uniquely short interspike intervals (2.5-20.0 ms). Motoneuronal delayed depolarization is commonly accepted to be doublet underlying mechanism. Apart from doublets, much scarcer MU triple discharges were described, but their mechanisms are disputable. The aim of the present study was to analyse MU triplet firing origin in healthy humans. MU triple discharges occasionally arising during gentle voluntary muscle contractions were compared with those arising in axons during motor nerve stimulation. Firing pattern was analysed in 109 MUs of four muscles: the tibialis anterior, the flexor carpi ulnaris, the abductor pollicis brevis, and the abductor digiti minimi. Our findings present evidence that during voluntary contractions two kinds of MU triplet firing can be occasionally observed: "true" motoneuronal triplets (interspike intervals of 3.6-17.3 ms) with the delayed depolarization as the possible underlying mechanism and axonal triple discharges including the M-response and F-wave. The findings can be useful not only for understanding mechanisms of the very rare motoneuronal firing in healthy humans but also for estimation of pathological triplet firing origin.
Hu, Xiaogang; Suresh, Aneesha K; Rymer, William Z; Suresh, Nina L
2017-01-01
Objective The advancement of surface electromyogram (sEMG) recording and signal processing techniques has allowed us to characterize the recruitment properties of a substantial population of motor units (MUs) non-invasively. Here we seek to determine whether MU recruitment properties are modified in paretic muscles of hemispheric stroke survivors. Approach Using an advanced EMG sensor array, we recorded sEMG during isometric contractions of the first dorsal interosseous muscle over a range of contraction levels, from 20% to 60% of maximum, in both paretic and contralateral muscles of stroke survivors. Using MU decomposition techniques, MU action potential amplitudes and recruitment thresholds were derived for simultaneously activated MUs in each isometric contraction. Main results Our results show a significant disruption of recruitment organization in paretic muscles, in that the size principle describing recruitment rank order was materially distorted. MUs were recruited over a very narrow force range with increasing force output, generating a strong clustering effect, when referenced to recruitment force magnitude. Such disturbances in MU properties also correlated well with the impairment of voluntary force generation. Significance Our findings provide direct evidence regarding MU recruitment modifications in paretic muscles of stroke survivors, and suggest that these modifications may contribute to weakness for voluntary contractions. PMID:26402920
Vibration and loads in hingeless rotors. Volume 1: Theoretical analyses
NASA Technical Reports Server (NTRS)
Watts, G. A.; London, R. J.
1972-01-01
Analytic methods are developed for calculating blade loads and shaft-transmitted vibratory forces in stiff bladed hingeless rotors operating at advance ratios from mu = .3 to mu = 2.0. Calculated shaft harmonic moments compared well with experimental values when the blade first flap frequency was in the region of two-per-revolution harmonic excitation. Calculated blade bending moment azimuthal distributions due to changes in cyclic pitch agreed well with experiment at radial stations near the blade root at values of the ratio of first flap frequency to rotor rotation rate from 1.5 to 5.0. At stations near the blade tip good agreement was only obtained at the higher values of frequency ratio.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rah, Jeong-Eun; Oh, Do Hoon; Shin, Dongho
Purpose: To evaluate and improve the reliability of proton quality assurance (QA) processes and, to provide an optimal customized tolerance level using the statistical process control (SPC) methodology. Methods: The authors investigated the consistency check of dose per monitor unit (D/MU) and range in proton beams to see whether it was within the tolerance level of the daily QA process. This study analyzed the difference between the measured and calculated ranges along the central axis to improve the patient-specific QA process in proton beams by using process capability indices. Results: The authors established a customized tolerance level of ±2% formore » D/MU and ±0.5 mm for beam range in the daily proton QA process. In the authors’ analysis of the process capability indices, the patient-specific range measurements were capable of a specification limit of ±2% in clinical plans. Conclusions: SPC methodology is a useful tool for customizing the optimal QA tolerance levels and improving the quality of proton machine maintenance, treatment delivery, and ultimately patient safety.« less
Thermodynamics of protein folding using a modified Wako-Saitô-Muñoz-Eaton model.
Tsai, Min-Yeh; Yuan, Jian-Min; Teranishi, Yoshiaki; Lin, Sheng Hsien
2012-09-01
Herein, we propose a modified version of the Wako-Saitô-Muñoz-Eaton (WSME) model. The proposed model introduces an empirical temperature parameter for the hypothetical structural units (i.e., foldons) in proteins to include site-dependent thermodynamic behavior. The thermodynamics for both our proposed model and the original WSME model were investigated. For a system with beta-hairpin topology, a mathematical treatment (contact-pair treatment) to facilitate the calculation of its partition function was developed. The results show that the proposed model provides better insight into the site-dependent thermodynamic behavior of the system, compared with the original WSME model. From this site-dependent point of view, the relationship between probe-dependent experimental results and model's thermodynamic predictions can be explained. The model allows for suggesting a general principle to identify foldon behavior. We also find that the backbone hydrogen bonds may play a role of structural constraints in modulating the cooperative system. Thus, our study may contribute to the understanding of the fundamental principles for the thermodynamics of protein folding.
SU-E-J-199: A Software Tool for Quality Assurance of Online Replanning with MR-Linac
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, G; Ahunbay, E; Li, X
2015-06-15
Purpose: To develop a quality assurance software tool, ArtQA, capable of automatically checking radiation treatment plan parameters, verifying plan data transfer from treatment planning system (TPS) to record and verify (R&V) system, performing a secondary MU calculation considering the effect of magnetic field from MR-Linac, and verifying the delivery and plan consistency, for online replanning. Methods: ArtQA was developed by creating interfaces to TPS (e.g., Monaco, Elekta), R&V system (Mosaiq, Elekta), and secondary MU calculation system. The tool obtains plan parameters from the TPS via direct file reading, and retrieves plan data both transferred from TPS and recorded during themore » actual delivery in the R&V system database via open database connectivity and structured query language. By comparing beam/plan datasets in different systems, ArtQA detects and outputs discrepancies between TPS, R&V system and secondary MU calculation system, and delivery. To consider the effect of 1.5T transverse magnetic field from MR-Linac in the secondary MU calculation, a method based on modified Clarkson integration algorithm was developed and tested for a series of clinical situations. Results: ArtQA is capable of automatically checking plan integrity and logic consistency, detecting plan data transfer errors, performing secondary MU calculations with or without a transverse magnetic field, and verifying treatment delivery. The tool is efficient and effective for pre- and post-treatment QA checks of all available treatment parameters that may be impractical with the commonly-used visual inspection. Conclusion: The software tool ArtQA can be used for quick and automatic pre- and post-treatment QA check, eliminating human error associated with visual inspection. While this tool is developed for online replanning to be used on MR-Linac, where the QA needs to be performed rapidly as the patient is lying on the table waiting for the treatment, ArtQA can be used as a general QA tool in radiation oncology practice. This work is partially supported by Elekta Inc.« less
Ceylan, Ozgur; Ugur, Aysel
2015-06-01
In this study, antimicrobial and antibiofilm activities and the chemical composition of Thymus sipyleus BOISS. subsp. sipyleus BOISS. var. davisianus RONNIGER essential oil was evaluated. The essential oil was obtained by hydro-distillation and analyzed by gas chromatography-mass spectrometry. Fourteen compounds were characterized, having as major components thymol (38.31%) and carvacrol (37.95%). Minimum inhibitory concentrations (MICs) of oil and the major components were calculated by serial dilution method, and anti-biofilm effects by microplate biofilm assay against five Gram positive (Staphylococcus aureus MU 38, MU 40, MU 46, MU 47, Stahylococcus epidermidis MU 30) and five Gram negative (Pseudomonas aeruginosa MU 187, MU 188, MU 189, Pseudomonas fluorescens MU 180, MU 181) bacteria. It was found that MICs for essential oil, thymol and carvacrol were between 5 and 50 µl/ml, 0.125-0.5 µg/ml and 0.125-05 µl/ml, respectively. The results showed that doses of MIC produced a greater anti-biofilm influence than 0.5, 0.25 and 0.125 MIC. In the presence of essential oil (MIC), the mean biofilm formation value was equal to 67 ± 5.5% for P. aeruginosa MU 188, and essential oil (MIC) inhibition exceeds 60% for P. aeruginosa biofilms. The results also showed that carvacrol (MIC) was able to induce an inhibition 72.9 ± 4.1% for S.aureus (MU 40) biofilm. In addition, thymol (MIC) showed 68.6 ± 5.3% reduction in biofilm formation of P. fluorescens MU 181. This study demonstrated the antimicrobial and antibiofilm activity of T. sipyleus BOISS. subsp. sipyleus BOISS. var. davisianus RONNIGER essential oil and points out the exceptional efficiency of thymol and carvacrol, which could represent candidates in the treatment of Pseudomonas and Staphylococcus biofilms.
Kaczmarek, P; Celichowski, J; Drzymała-Celichowska, H; Kasiński, A
2009-08-01
The mechanomyographic (MMG) signal analysis has been performed during single motor unit (MU) contractions of the rat medial gastrocnemius muscle. The MMG has been recorded as a muscle surface displacement by using a laser distance sensor. The profiles of the MMG signal let to categorize these signals for particular MUs into three classes. Class MMG-P (positive) comprises MUs with the MMG signal similar to the force signal profile, where the distance between the muscle surface and the laser sensor increases with the force increase. The class MMG-N (negative) has also the MMG profile similar to the force profile, however the MMG is inverted in comparison to the force signal and the distance measured by using laser sensor decreases with the force increase. The third class MMG-M (mixed) characterize the MMG which initially increases with the force increases and when the force exceeds some level it starts to decrease towards the negative values. The semi-pennate muscle model has been proposed, enabling estimation of the MMG generated by a single MU depending on its localization. The analysis have shown that in the semi-pennate muscle the localization of the MU and the relative position of the laser distance sensor determine the MMG profile and amplitude. Thus, proposed classification of the MMG recordings is not related to the physiological types of MUs, but only to the MU localization and mentioned sensor position. When the distance sensor is located over the middle of the muscle belly, a part of the muscle fibers have endings near the location of the sensor beam. For the MU MMG of class MMG-N the deflection of the muscle surface proximal to the sensor mainly influences the MMG recording, whereas for the MU MMG class MMG-P, it is mainly the distal muscle surface deformation. For the MU MMG of MMG-M type the effects of deformation within the proximal and distal muscle surfaces overlap. The model has been verified with experimental recordings, and its responses are consistent and adequate in comparison to the experimental data.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Soundy, R.G.; Simpson, J.D.; Ross, H.M.
The absorbed radiation dose that would result from the oral or intravenous administration of SeHCAT (23-(/sup 75/Se)selena-25-homotaurocholate) has been calculated using the MIRD tables and formulas and data from measurements of whole-body distribution and from long-term whole-body counting in rats, mice, and man. When SeHCAT is administered to normal subjects, the gallbladder is the critical organ, receiving 12 mrad (oral dose) or 22 mrad (i.v.) per microcurie. The whole-body dose is 1 mrad/..mu..Ci, whatever the route of administration. In severe hepatic failure the liver might receive 200 mrad/..mu..Ci. The activity likely to be used in routine clinical practice is 10more » ..mu..Ci. Where a whole-body counter is used, an activity of 1 ..mu..Ci has proved adequate. Even at an administered activity of 25 ..mu..Ci, the absorbed dose is small compared with established techniques of investigating the gastrointestinal tract.« less
Proton, muon and ¹³C hyperfine coupling constants of C₆₀X and C₇₀X (X = H, Mu).
Brodovitch, Jean-Claude; Addison-Jones, Brenda; Ghandi, Khashayar; McKenzie, Iain; Percival, Paul W
2015-01-21
The reaction of H atoms with fullerene C70 has been investigated by identifying the radical products formed by addition of the atom muonium (Mu) to the fullerene in solution. Four of the five possible radical isomers of C70Mu were detected by avoided level-crossing resonance (μLCR) spectroscopy, using a dilute solution of enriched (13)C70 in decalin. DFT calculations were used to predict muon and (13)C isotropic hyperfine constants as an aid to assigning the observed μLCR signals. Computational methods were benchmarked against previously published experimental data for (13)C60Mu in solution. Analysis of the μLCR spectrum resulted in the first experimental determination of (13)C hyperfine constants in either C70Mu or C70H. The large number of values confirms predictions that the four radical isomers have extended distributions of unpaired electron spin.
Multiphoton dissociation and thermal unimolecular reactions induced by infrared lasers. [REAMPA code
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dai, H.L.
1981-04-01
Multiphoton dissociation (MPD) of ethyl chloride was studied using a tunable 3.3 ..mu..m laser to excite CH stretches. The absorbed energy increases almost linearly with fluence, while for 10 ..mu..m excitation there is substantial saturation. Much higher dissociation yields were observed for 3.3 ..mu..m excitation than for 10 ..mu..m excitation, reflecting bottlenecking in the discrete region of 10 ..mu..m excitation. The resonant nature of the excitation allows the rate equations description for transitions in the quasicontinuum and continuum to be extended to the discrete levels. Absorption cross sections are estimated from ordinary ir spectra. A set of cross sections whichmore » is constant or slowly decreasing with increasing vibrational excitation gives good fits to both absorption and dissociation yield data. The rate equations model was also used to quantitatively calculate the pressure dependence of the MPD yield of SF/sub 6/ caused by vibrational self-quenching. Between 1000-3000 cm/sup -1/ of energy is removed from SF/sub 6/ excited to approx. > 60 kcal/mole by collision with a cold SF/sub 6/ molecule at gas kinetic rate. Calculation showed the fluence dependence of dissociation varies strongly with the gas pressure. Infrared multiphoton excitation was applied to study thermal unimolecular reactions. With SiF/sub 4/ as absorbing gas for the CO/sub 2/ laser pulse, transient high temperature pulses were generated in a gas mixture. IR fluorescence from the medium reflected the decay of the temperature. The activation energy and the preexponential factor of the reactant dissociation were obtained from a phenomenological model calculation. Results are presented in detail. (WHK)« less
Dose optimization of total or partial skin electron irradiation by thermoluminescent dosimetry.
Schüttrumpf, Lars; Neumaier, Klement; Maihoefer, Cornelius; Niyazi, Maximilian; Ganswindt, Ute; Li, Minglun; Lang, Peter; Reiner, Michael; Belka, Claus; Corradini, Stefanie
2018-05-01
Due to the complex surface of the human body, total or partial skin irradiation using large electron fields is challenging. The aim of the present study was to quantify the magnitude of dose optimization required after the application of standard fields. Total skin electron irradiation (TSEI) was applied using the Stanford technique with six dual-fields. Patients presenting with localized lesions were treated with partial skin electron irradiation (PSEI) using large electron fields, which were individually adapted. In order to verify and validate the dose distribution, in vivo dosimetry with thermoluminescent dosimeters (TLD) was performed during the first treatment fraction to detect potential dose heterogeneity and to allow for an individual dose optimization with adjustment of the monitor units (MU). Between 1984 and 2017, a total of 58 patients were treated: 31 patients received TSEI using 12 treatment fields, while 27 patients underwent PSEI and were treated with 4-8 treatment fields. After evaluation of the dosimetric results, an individual dose optimization was necessary in 21 patients. Of these, 7 patients received TSEI (7/31). Monitor units (MU) needed to be corrected by a mean value of 117 MU (±105, range 18-290) uniformly for all 12 treatment fields, corresponding to a mean relative change of 12% of the prescribed MU. In comparison, the other 14 patients received PSEI (14/27) and the mean adjustment of monitor units was 282 MU (±144, range 59-500) to single or multiple fields, corresponding to a mean relative change of 22% of the prescribed MU. A second dose optimization to obtain a satisfying dose at the prescription point was need in 5 patients. Thermoluminescent dosimetry allows an individual dose optimization in TSEI and PSEI to enable a reliable adjustment of the MUs to obtain the prescription dose. Especially in PSEI in vivo dosimetry is of fundamental importance.
Differential Motor Unit Changes after Endurance or High-Intensity Interval Training.
Martinez-Valdes, Eduardo; Falla, Deborah; Negro, Francesco; Mayer, Frank; Farina, Dario
2017-06-01
Using a novel technique of high-density surface EMG decomposition and motor unit (MU) tracking, we compared changes in the properties of vastus medialis and vastus lateralis MU after endurance (END) and high-intensity interval training (HIIT). Sixteen men were assigned to the END or the HIIT group (n = 8 each) and performed six training sessions for 14 d. Each session consisted of 8-12 × 60-s intervals at 100% peak power output separated by 75 s of recovery (HIIT) or 90-120 min continuous cycling at ~65% V˙O2peak (END). Pre- and postintervention, participants performed 1) incremental cycling to determine V˙O2peak and peak power output and 2) maximal, submaximal (10%, 30%, 50%, and 70% maximum voluntary contraction [MVC]), and sustained (until task failure at 30% MVC) isometric knee extensions while high-density surface EMG signals were recorded from the vastus medialis and vastus lateralis. EMG signals were decomposed (submaximal contractions) into individual MU by convolutive blind source separation. Finally, MU were tracked across sessions by semiblind source separation. After training, END and HIIT improved V˙O2peak similarly (by 5.0% and 6.7%, respectively). The HIIT group showed enhanced maximal knee extension torque by ~7% (P = 0.02) and was accompanied by an increase in discharge rate for high-threshold MU (≥50% knee extension MVC) (P < 0.05). By contrast, the END group increased their time to task failure by ~17% but showed no change in MU discharge rates (P > 0.05). HIIT and END induce different adjustments in MU discharge rate despite similar improvements in cardiopulmonary fitness. Moreover, the changes induced by HIIT are specific for high-threshold MU. For the first time, we show that HIIT and END induce specific neuromuscular adaptations, possibly related to differences in exercise load intensity and training volume.
A transceiver module of the Mu radar
NASA Technical Reports Server (NTRS)
Kato, S.; Ogawa, T.; Tsuda, T.; Sato, T.; Kimura, I.; Fukao, S.
1983-01-01
The transceiver (TR) module of a middle and upper atmospheric radar is described. The TR module used in the radar is mainly composed of two units: a mixer (MIX unit) and a power amplifier (PA unit). The former generates the RF wave for transmission and converts the received echo to the IF signal. A 41.5-MHz local signal fed to mixers passes through a digitally controlled 8-bit phase shifter which can change its value up to 1,000 times in a second, so that the MU radar has the ability to steer its antenna direction quickly and flexibly. The MIX unit also contains a buffer amplifier and a gate for the transmitting signal and preamplifier for the received one whose noise figure is less than 5 dB. The PA unit amplifies the RF signal supplied from the MIX unit up to 63.7 dBm (2350 W), and feeds it to the crossed Yagi antenna.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brason, J G
1977-05-01
Inclusive muon pair production by 225 GeV/c ..pi../sup +/, ..pi../sup -/ and proton beams incident upon carbon and tin targets was measured over a large range of kinematic variables (2m/sub ..mu../ < m/sub ..mu mu.. < 1 GeV/c/sup 2/, 0 < x/sub F/ < 1, P/sub perpendicular to/ < 4 GeV/c and vertical bar cos theta* vertical bar < .3). The value of the invariant cross section E d/sup 4/sigma/dmdx/sub f/dp/sup 2//sub perpendicular to/ is presented as a function of these variables. The vector mesons rho, ..omega.., phi, J and psi' appear in the data along with apparently nonresonant ..mu..-pairs.more » By looking for additional muons accompanying J ..-->.. ..mu../sup +/..mu../sup -/ events, a 1.0% upper limit on production of pairs of charmed particles in association with the J is obtained. Aspects of the continuum muon pair data are compared to Drell-Yan model calculations. The ratio of ..mu..-pairs produced by ..pi../sup +/ beam particles to ..mu..-pairs produced by ..pi../sup -/ beam particles supports electromagnetic production at high mass.« less
Rate constants for the slow Mu + propane abstraction reaction at 300 K by diamagnetic RF resonance.
Fleming, Donald G; Cottrell, Stephen P; McKenzie, Iain; Ghandi, Khashayar
2015-08-14
The study of kinetic isotope effects for H-atom abstraction rates by incident H-atoms from the homologous series of lower mass alkanes (CH4, C2H6 and, here, C3H8) provides important tests of reaction rate theory on polyatomic systems. With a mass of only 0.114 amu, the most sensitive test is provided by the rates of the Mu atom. Abstraction of H by Mu can be highly endoergic, due to the large zero-point energy shift in the MuH bond formed, which also gives rise to high activation energies from similar zero-point energy corrections at the transition state. Rates are then far too slow near 300 K to be measured by conventional TF-μSR techniques that follow the disappearance of the spin-polarised Mu atom with time. Reported here is the first measurement of a slow Mu reaction rate in the gas phase by the technique of diamagnetic radio frequency (RF) resonance, where the amplitude of the MuH product formed in the Mu + C3H8 reaction is followed with time. The measured rate constant, kMu = (6.8 ± 0.5) × 10(-16) cm(3) s(-1) at 300 K, is surprisingly only about a factor of three slower than that expected for H + C3H8, indicating a dominant contribution from quantum tunneling in the Mu reaction, consistent with elementary transition state theory calculations of the kMu/kH kinetic isotope effect.
Wilson, Zakiya S; Stanley, George G; Vicic, David A
2010-06-21
The M-H-M bonding in the dinuclear complexes Ni(2)(mu-H)(mu-P(2))(2)X(2) (P(2) = R(2)PCH(2)PR(2), R = iPr, Cy; X = Cl, Br) has been investigated. These dinickel A-frames were studied via density functional theory (DFT) calculations to analyze the factors that influence linear and bent M-H-M bonding. The DFT calculations indicate that the bent geometry is favored electronically, with ligand steric effects driving the formation of the linear M-H-M structures.
NASA Astrophysics Data System (ADS)
Holobar, A.; Minetto, M. A.; Farina, D.
2014-02-01
Objective. A signal-based metric for assessment of accuracy of motor unit (MU) identification from high-density surface electromyograms (EMG) is introduced. This metric, so-called pulse-to-noise-ratio (PNR), is computationally efficient, does not require any additional experimental costs and can be applied to every MU that is identified by the previously developed convolution kernel compensation technique. Approach. The analytical derivation of the newly introduced metric is provided, along with its extensive experimental validation on both synthetic and experimental surface EMG signals with signal-to-noise ratios ranging from 0 to 20 dB and muscle contraction forces from 5% to 70% of the maximum voluntary contraction. Main results. In all the experimental and simulated signals, the newly introduced metric correlated significantly with both sensitivity and false alarm rate in identification of MU discharges. Practically all the MUs with PNR > 30 dB exhibited sensitivity >90% and false alarm rates <2%. Therefore, a threshold of 30 dB in PNR can be used as a simple method for selecting only reliably decomposed units. Significance. The newly introduced metric is considered a robust and reliable indicator of accuracy of MU identification. The study also shows that high-density surface EMG can be reliably decomposed at contraction forces as high as 70% of the maximum.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-06
... ignition sources, hot work activities (activities such as welding or grinding), in situ and transient... is \\1/4\\- inch outside diameter tubing used for testing reactor building pressure switches. This... testing on the MU-V-20 backup air supply demonstrated that MU-V- 20 would only stay open for approximately...
MU06-857, a Green Leaf Lettuce Breeding Line with Resistance to Leafminer and Lettuce Mosaic Virus.
USDA-ARS?s Scientific Manuscript database
The Agricultural Research Service, United States Department of Agriculture announces the release of a breeding line of green leaf lettuce (Lactuca sativa L.) with resistance to leafminers (Liriomyza langei Frick) and lettuce mosaic. The line MU06-857 is similar to cultivar ‘Lolla Rossa’ (‘Lollo Ros...
Gravitational lensing effects of vacuum strings - Exact solutions
NASA Technical Reports Server (NTRS)
Gott, J. R., III
1985-01-01
Exact interior and exterior solutions to Einstein's field equations are derived for vacuum strings. The exterior solution for a uniform density vacuum string corresponds to a conical space while the interior solution is that of a spherical cap. For Mu equals 0-1/4 the external metric is ds-squared = -dt-squared + dr-squared + (1-4 Mu)-squared r-squared dphi-squared + dz-squared, where Mu is the mass per unit length in the string in Planck masses per Planck length. A maximum mass per unit length for a string is 6.73 x 10 to the 27th g/cm. It is shown that strings cause temperature fluctuations in the cosmic microwave background and produce equal brightness double QSO images separated by up to several minutes of arc. Formulae for lensing probabilities, image splittings, and time delays are derived for strings in a realistic cosmological setting. String searches using ST, the VLA, and the COBE satellite are discussed.
In modern linacs monitor units should be defined in water at 10 cm depth rather than at dmax.
Van den Heuvel, Frank; Wu, Qiuwen; Cai, Jing
2018-05-28
Thanks to the widely adopted guidelines such as AAPM TG-51 1 and IAEA TRS-398 2 , linac calibration has become more consistent and accurate around the globe than previously. Modern linac photon beams are often calibrated in water at 10 cm depth, and configured such that 1 monitor unit (MU) corresponds to 1 cGy at the depth of maximum dose, (d max) . However, such configuration is not without limitations. Some think it is unnecessarily complex and prone to errors, and believe that defining MU at 10 cm is more appropriate. Others think that change of MU definition can cause confusion and possibly serious consequences without any real benefit. This is the premise debated in this month's Point/Counterpoint. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Probing the Watson-Crick, wobble, and sugar-edge hydrogen bond sites of uracil and thymine.
Müller, Andreas; Frey, Jann A; Leutwyler, Samuel
2005-06-16
The nucleobases uracil (U) and thymine (T) offer three hydrogen-bonding sites for double H-bond formation via neighboring N-H and C=O groups, giving rise to the Watson-Crick, wobble and sugar-edge hydrogen bond isomers. We probe the hydrogen bond properties of all three sites by forming hydrogen bonded dimers of U, 1-methyluracil (1MU), 3-methyluracil (3MU), and T with 2-pyridone (2PY). The mass- and isomer-specific S1 <-- S0 vibronic spectra of 2PY.U, 2PY.3MU, 2PY.1MU, and 2PY.T were measured using UV laser resonant two-photon ionization (R2PI). The spectra of the Watson-Crick and wobble isomers of 2PY.1MU were separated using UV-UV spectral hole-burning. We identify the different isomers by combining three different diagnostic tools: (1) Selective methylation of the uracil N3-H group, which allows formation of the sugar-edge isomer only, and methylation of the N1-H group, which leads to formation of the Watson-Crick and wobble isomers. (2) The experimental S1 <-- S0 origins exhibit large spectral blue shifts relative to the 2PY monomer. Ab initio CIS calculations of the spectral shifts of the different hydrogen-bonded dimers show a linear correlation with experiment. This correlation allows us to identify the R2PI spectra of the weakly populated Watson-Crick and wobble isomers of both 2PY.U and 2PY.T. (3) PW91 density functional calculation of the ground-state binding and dissociation energies De and D0 are in agreement with the assignment of the dominant hydrogen bond isomers of 2PY.U, 2PY.3MU and 2PY.T as the sugar-edge form. For 2PY.U, 2PY.T and 2PY.1MU the measured wobble:Watson-Crick:sugar-edge isomer ratios are in good agreement with the calculated ratios, based on the ab initio dissociation energies and gas-phase statistical mechanics. The Watson-Crick and wobble isomers are thereby determined to be several kcal/mol less strongly bound than the sugar-edge isomers. The 36 observed intermolecular frequencies of the nine different H-bonded isomers give detailed insight into the intermolecular force field.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Syh, J; Ding, X; Syh, J
2015-06-15
Purpose: An approved proton pencil beam scanning (PBS) treatment plan might not be able to deliver because of existed extremely low monitor unit per beam spot. A dual hybrid plan with higher efficiency of higher spot monitor unit and the efficacy of less number of energy layers were searched and optimized. The range of monitor unit threshold setting was investigated and the plan quality was evaluated by target dose conformity. Methods: Certain limitations and requirements need to be checks and tested before a nominal proton PBS treatment plan can be delivered. The plan needs to be met the machine characterization,more » specification in record and verification to deliver the beams. Minimal threshold of monitor unit, e.g. 0.02, per spot was set to filter the low counts and plan was re-computed. Further MU threshold increment was tested in sequence without sacrificing the plan quality. The number of energy layer was also alternated due to elimination of low count layer(s). Results: Minimal MU/spot threshold, spot spacing in each energy layer and total number of energy layer and the MU weighting of beam spots of each beam were evaluated. Plan optimization between increases of the spot MU (efficiency) and less energy layers of delivery (efficacy) was adjusted. 5% weighting limit of total monitor unit per beam was feasible. Scarce spreading of beam spots was not discouraging as long as target dose conformity within 3% criteria. Conclusion: Each spot size is equivalent to the relative dose in the beam delivery system. The energy layer is associated with the depth of the targeting tumor. Our work is crucial to maintain the best possible quality plan. To keep integrity of all intrinsic elements such as spot size, spot number, layer number and the carried weighting of spots in each layer is important in this study.« less
Azumah, Bright K.; Addo, Phyllis G.; Dodoo, Alfred; Awandare, Gordon; Mosi, Lydia; Boakye, Daniel A.
2017-01-01
The transmission of Buruli ulcer (BU), caused by Mycobacterium ulcerans (MU), remains puzzling although a number of hypothesis including through bites of infected aquatic insects have been proposed. We report the results of experiments using ICR mice that give credence to our hypothesis that Acanthamoeba species may play a role in BU transmission. We cocultured MU N2 and MU 1615 which expresses red fluorescent protein (RFP) and Acanthamoeba polyphaga (AP), and confirmed infected AP by Ziehl-Neelsen (ZN) staining. We tested for viability of MU inside AP and observed strong RFP signals inside both trophozoites and cysts after 3 and 42 days of coculturing respectively. ICR mice were topically treated, either on shaved intact or shaved pinpricked rumps, with one of the following; MU N2 only (2.25 x 106 colony forming units [CFU] / ml), MU N2:AP coculture (2.96 x 104 CFU: 1.6 x 106 cells/ml), AP only (1.6 x 106 cells/ml), PYG medium and sterile distilled water. Both MU N2 only and MU N2:AP elicited reddening on day (D) 31; edema on D 45 and D 44 respectively, and ulcers on D 49 at pinpricked sites only. To ascertain infectivity and pathogenicity of MU N2 only and MU N2:AP, and compare their virulence, the standard mouse footpad inoculation method was used. MU N2:AP elicited reddening in footpads by D 3 compared to D 14 with MU N2 only of the same dose of MU N2 (2.96 x 104 CFU). ZN-stained MU were observed in both thin sectioned and homogenized lesions, and aspirates from infected sites. Viable MU N2 were recovered from cultures of the homogenates and aspirates. This study demonstrates in ICR mice MU transmission via passive infection, and shows that punctures in the skin are prerequisite for infection, and that coculturing of MU with AP enhances pathogenesis. PMID:28329001
Environmental Impact From Accelerator Operation at SLAC
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, James C
1999-03-22
Environmental impacts from electron accelerator operations at the Stanford Linear Accelerator Center, which is located near populated areas, are illustrated by using examples of three different accelerator facilities: the low power (a few watts) SSRL, the high power (a few kilowatts) PEP-II, and the 50-kW SLC. Three types of major impacts are discussed: (1) off-site doses from skyshine radiation, mainly neutrons, (2) off-site doses from radioactive air emission, mainly {sup 13}N, and (3) radioactivities, mainly {sup 3}H, produced in the groundwater. It was found that, from SSRL operation, the skyshine radiation result in a MEI (Maximum Exposed Individual) of 0.3more » {mu}Sv/y while a conservative calculation using CAP88 showed a MEI of 0.36 {mu}Sv/y from radioactive air releases. The calculated MEI doses due to future PEP-II operation are 30 {mu}Sv/y from skyshine radiation and 2 {mu}Sv/y from air releases. The population doses due to radioactive air emission are 0.5 person-mSv from SSRL and 12 person-mSv from PEP-II. Because of the stronger decrease of skyshine dose as the distance increases, the population dose from skyshine radiation are smaller than that from air release. The third environmental impact, tritium activity produced in the groundwater, was also demonstrated to be acceptable from both the well water measurements and the FLUKA calculations for the worst case of the SLC high-power dump.« less
Associations between motor unit action potential parameters and surface EMG features.
Del Vecchio, Alessandro; Negro, Francesco; Felici, Francesco; Farina, Dario
2017-10-01
The surface interference EMG signal provides some information on the neural drive to muscles. However, the association between neural drive to muscle and muscle activation has long been debated with controversial indications due to the unavailability of motor unit population data. In this study, we clarify the potential and limitations of interference EMG analysis to infer motor unit recruitment strategies with an experimental investigation of several concurrently active motor units and of the associated features of the surface EMG. For this purpose, we recorded high-density surface EMG signals during linearly increasing force contractions of the tibialis anterior muscle, up to 70% of maximal force. The recruitment threshold (RT), conduction velocity (MUCV), median frequency (MDF MU ), and amplitude (RMS MU ) of action potentials of 587 motor units from 13 individuals were assessed and associated with features of the interference EMG. MUCV was positively associated with RT ( R 2 = 0.64 ± 0.14), whereas MDF MU and RMS MU showed a weaker relation with RT ( R 2 = 0.11 ± 0.11 and 0.39 ± 0.24, respectively). Moreover, the changes in average conduction velocity estimated from the interference EMG predicted well the changes in MUCV ( R 2 = 0.71), with a strong association to ankle dorsiflexion force ( R 2 = 0.81 ± 0.12). Conversely, both the average EMG MDF and RMS were poorly associated with motor unit recruitment. These results clarify the limitations of EMG spectral and amplitude analysis in inferring the neural strategies of muscle control and indicate that, conversely, the average conduction velocity could provide relevant information on these strategies. NEW & NOTEWORTHY The surface EMG provides information on the neural drive to muscles. However, the associations between EMG features and neural drive have been long debated due to unavailability of motor unit population data. Here, by using novel highly accurate decomposition of the EMG, we related motor unit population behavior to a wide range of voluntary forces. The results fully clarify the potential and limitation of the surface EMG to provide estimates of the neural drive to muscles. Copyright © 2017 the American Physiological Society.
Assessment of three dead detector correction methods for cone-beam computed tomography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nelms, David W.; Shukla, Hemant I.; Nixon, Earl
Purpose: Dead detectors due to manufacturing defects or radiation damage in the electronic portal imaging devices (EPIDs) used for cone-beam computed tomography (CBCT) can lead to image degradation and ring artifacts. In this work three dead detector correction methods were assessed using megavoltage CBCT (MVCBCT) as a test system, with the goals of assessing the relative effectiveness of the three methods and establishing the conditions for which they fail. Methods: MVCBCT projections acquired with four linacs at 8 and 60 MU (monitor units) were degraded with varying percentages (2%-95%) of randomly distributed dead single detectors (RDSs), randomly distributed dead detectormore » clusters (RDCs) of 2 mm diameter, and nonrandomly distributed dead detector disks (NRDDs) of varying diameter (4-16 mm). Correction algorithms were bidirectional linear interpolation (BLI), quad-directional linear interpolation (QLI), and a Laplacian solution (LS) method. Correction method failure was defined to occur if ring artifacts were present in the reconstructed phantom images from any linac or if the modulation transfer function (MTF) for any linac dropped below baseline with a p value, calculated with the two sample t test, of less than 0.01. Results: All correction methods failed at the same or lower RDC/RDS percentages and NRDD diameters for the 60 MU as for the 8 MU cases. The LS method tended to outperform or match the BLI and QLI methods. If ring artifacts anywhere in the images were considered unacceptable, the LS method failed for 60 MU at >33% RDS, >2% RDC, and >4 mm NRDD. If ring artifacts within 4 mm longitudinally of the phantom section interfaces were considered acceptable, the LS method failed for 60 MU at >90% RDS, >80% RDC, and >4 mm NRDD. LS failed due to MTF drop for 60 MU at >50% RDS, >25% RDC, and >4 mm NRDD. Conclusions: The LS method is superior to the BLI and QLI methods, and correction algorithm effectiveness decreases as imaging dose increases. All correction methods failed first due to ring artifacts and second due to MTF drop. If ring artifacts in axial slices within a 4 mm longitudinal distance from phantom section interfaces are acceptable, statistically significant loss in spatial resolution does not occur until over 25% of the EPID is covered in randomly distributed dead detectors, or NRDDs of 4 mm diameter are present.« less
SU-E-T-261: Plan Quality Assurance of VMAT Using Fluence Images Reconstituted From Log-Files
DOE Office of Scientific and Technical Information (OSTI.GOV)
Katsuta, Y; Shimizu, E; Matsunaga, K
2014-06-01
Purpose: A successful VMAT plan delivery includes precise modulations of dose rate, gantry rotational and multi-leaf collimator (MLC) shapes. One of the main problem in the plan quality assurance is dosimetric errors associated with leaf-positional errors are difficult to analyze because they vary with MU delivered and leaf number. In this study, we calculated integrated fluence error image (IFEI) from log-files and evaluated plan quality in the area of all and individual MLC leaves scanned. Methods: The log-file reported the expected and actual position for inner 20 MLC leaves and the dose fraction every 0.25 seconds during prostate VMAT onmore » Elekta Synergy. These data were imported to in-house software that developed to calculate expected and actual fluence images from the difference of opposing leaf trajectories and dose fraction at each time. The IFEI was obtained by adding all of the absolute value of the difference between expected and actual fluence images corresponding. Results: In the area all MLC leaves scanned in the IFEI, the average and root mean square (rms) were 2.5 and 3.6 MU, the area of errors below 10, 5 and 3 MU were 98.5, 86.7 and 68.1 %, the 95 % of area was covered with less than error of 7.1 MU. In the area individual MLC leaves scanned in the IFEI, the average and rms value were 2.1 – 3.0 and 3.1 – 4.0 MU, the area of errors below 10, 5 and 3 MU were 97.6 – 99.5, 81.7 – 89.5 and 51.2 – 72.8 %, the 95 % of area was covered with less than error of 6.6 – 8.2 MU. Conclusion: The analysis of the IFEI reconstituted from log-file was provided detailed information about the delivery in the area of all and individual MLC leaves scanned.« less
SU-F-T-263: Dosimetric Characteristics of the Cine Acquisition Mode of An A-Si EPID
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bawazeer, O; Deb, P; Sarasanandarajah, S
2016-06-15
Purpose: To investigate the dosimetric characteristics of Varian a-Si-500 electronic portal imaging device (EPID) operated in cine mode particularly considering linearity with delivered dose, dose rate, field size, phantom thickness, MLC speed and common IMRT fields. Methods: The EPID that attached to a Varian Clinac 21iX linear accelerator, was irradiated with 6 and 18 MV using 600 MU/min. Image acquisition is controlled by the IAS3 software, Trigger delay was 6 ms, BeamOnDelay and FrameStartDelay were zero. Different frame rates were utilized. Cine mode response was calculated using MATLAB as summation of mean pixel values in a region of interest ofmore » the acquired images. The performance of cine mode was compared to integrated mode and dose measurements in water using CC13 ionization chamber. Results: Figure1 illustrates that cine mode has nonlinear response for small MU, when delivering 10 MU was about 0.5 and 0.64 for 6 and 18 MV respectively. This is because the missing acquired images that were calculated around four images missing in each delivery. With the increase MU the response became linear and comparable with integrated mode and ionization chamber within 2%. Figure 2 shows that cine mode has comparable response with integrated mode and ionization chamber within 2% with changing dose rate for 10 MU delivered. This indicates that the dose rate change has no effect on nonlinearity of cine mode response. Except nonlinearity, cine mode is well matched to integrated mode response within 2% for field size, phantom thickness, MLC speed dependences. Conclusion: Cine mode has similar dosimetric characteristics to integrated mode with open and IMRT fields, and the main limitation with cine mode is missing images. Therefore, the calibration of EPID images with this mode should be run with large MU, and when IMRT verification field has low MU, the correction for missing images are required.« less
A combinatorial model for the Macdonald polynomials.
Haglund, J
2004-11-16
We introduce a polynomial C(mu)[Z; q, t], depending on a set of variables Z = z(1), z(2),..., a partition mu, and two extra parameters q, t. The definition of C(mu) involves a pair of statistics (maj(sigma, mu), inv(sigma, mu)) on words sigma of positive integers, and the coefficients of the z(i) are manifestly in N[q,t]. We conjecture that C(mu)[Z; q, t] is none other than the modified Macdonald polynomial H(mu)[Z; q, t]. We further introduce a general family of polynomials F(T)[Z; q, S], where T is an arbitrary set of squares in the first quadrant of the xy plane, and S is an arbitrary subset of T. The coefficients of the F(T)[Z; q, S] are in N[q], and C(mu)[Z; q, t] is a sum of certain F(T)[Z; q, S] times nonnegative powers of t. We prove F(T)[Z; q, S] is symmetric in the z(i) and satisfies other properties consistent with the conjecture. We also show how the coefficient of a monomial in F(T)[Z; q, S] can be expressed recursively. maple calculations indicate the F(T)[Z; q, S] are Schur-positive, and we present a combinatorial conjecture for their Schur coefficients when the set T is a partition with at most three columns.
NASA Technical Reports Server (NTRS)
Premo, Wayne R.; Tatsumoto, M.
1992-01-01
The U-Th-Pb, Rb-Sr, and Sm-Nd isotopic systematics of four lightly leached residues of pristine, high-Mg, troctolitic cumulate 76535 were analyzed in order to determine their ages and magma sources. The data indicate that the cumulate was in isotopic equilibrium with a fluid or magma characterized by a high U-238/Pb-204 (mu) value of 600 at 4.236 Ga. Two and three stage Pb evolution calculations define even greater source mu values of about 1000, assuming low lunar initial mu values between 5 and 40 prior to about 4.43 Ga. These results are similar to mu values for KREEP sources and are also consistent with values from 78235, suggesting that at least some high-Mg suite rocks were derived from magma sources with high-mu values similar to KREEP, and support that idea that these rocks postdate primary lunar differentiation and formation of ferroan anorthosites.
Density functional theory and an experimentally-designed energy functional of electron density.
Miranda, David A; Bueno, Paulo R
2016-09-21
We herein demonstrate that capacitance spectroscopy (CS) experimentally allows access to the energy associated with the quantum mechanical ground state of many-electron systems. Priorly, electrochemical capacitance, C [small mu, Greek, macron] [ρ], was previously understood from conceptual and computational density functional theory (DFT) calculations. Thus, we herein propose a quantum mechanical experiment-based variational method for electron charging processes based on an experimentally-designed functional of the ground state electron density. In this methodology, the electron state density, ρ, and an energy functional of the electron density, E [small mu, Greek, macron] [ρ], can be obtained from CS data. CS allows the derivative of the electrochemical potential with respect to the electron density, (δ[small mu, Greek, macron][ρ]/δρ), to be obtained as a unique functional of the energetically minimised system, i.e., β/C [small mu, Greek, macron] [ρ], where β is a constant (associated with the size of the system) and C [small mu, Greek, macron] [ρ] is an experimentally observable quantity. Thus the ground state energy (at a given fixed external potential) can be obtained simply as E [small mu, Greek, macron] [ρ], from the experimental measurement of C [small mu, Greek, macron] [ρ]. An experimental data-set was interpreted to demonstrate the potential of this quantum mechanical experiment-based variational principle.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qu, H; Qi, P; Yu, N
Purpose: To implement and validate a method of using electronic portal image device (EPID) for pre-treatment quality assurance (QA) of volumetric modulated arc therapy (VMAT) plans using flattering filter free (FFF) beams for stereotactic body radiotherapy (SBRT). Methods: On Varian Edge with 6MV FFF beam, open field (from 2×2 cm to 20×20 cm) EPID images were acquired with 200 monitor unit (MU) at the image device to radiation source distance of 150cm. With 10×10 open field and calibration unit (CU) provided by vendor to EPID image pixel, a dose conversion factor was determined by dividing the center dose calculated frommore » the treatment planning system (TPS) to the corresponding CU readout on the image. Water phantom measured beam profile and the output factors for various field sizes were further correlated to those of EPID images. The dose conversion factor and correction factors were then used for converting the portal images to the planner dose distributions of clinical fields. A total of 28 VMAT fields of 14 SBRT plans (8 lung, 2 prostate, 2 liver and 2 spine) were measured. With 10% low threshold cutoff, the delivered dose distributions were compared to the reference doses calculated in water phantom from the TPS. A gamma index analysis was performed for the comparison in percentage dose difference/distance-to-agreement specifications. Results: The EPID device has a linear response to the open fields with increasing MU. For the clinical fields, the gamma indices between the converted EPID dose distributions and the TPS calculated 2D dose distributions were 98.7%±1.1%, 94.0%±3.4% and 70.3%±7.7% for the criteria of 3%/3mm, 2%/2mm and 1%/1mm, respectively. Conclusion: Using a portal image device, a high resolution and high accuracy portal dosimerty was achieved for pre-treatment QA verification for SBRT VMAT plans with FFF beams.« less
Uddin, Md Nazim; Begum, Noorjahan; Hassan, Mohammad R; Hogarth, Graeme; Kabir, Shariff E; Miah, Md Arzu; Nordlander, Ebbe; Tocher, Derek A
2008-11-28
The synthesis and reactivity of the thiophyne and furyne clusters [Ru3(CO)7(mu-dppm)(mu3-eta2-C4H2E)(mu-P(C4H3E)2)(mu-H)] (E = S, O) is reported. Addition of P(C4H3E)3 to [Ru3(CO)10(mu-dppm)] (1) at room temperature in the presence of Me3NO gives simple substitution products [Ru3(CO)9(mu-dppm)(P(C4H3E)3)] (E = S, 2; E = O, 3). Mild thermolysis in the presence of further Me3NO affords the thiophyne and furyne complexes [Ru3(CO)7(mu-dppm)(mu3-eta2-C4H2E)(mu-P(C4H3E)2)(mu-H)] (E = S, 4; E = O, 6) resulting from both carbon-hydrogen and carbon-phosphorus bond activation. In each the C4H2E (E = S, O) ligand donates 4-electrons to the cluster and the rings are tilted with respect to the mu-dppm and the phosphido-bridged open triruthenium unit. Heating 4 at 80 degrees C leads to the formation of the ring-opened cluster [Ru3(CO)5(mu-CO)(mu-dppm)(mu3-eta3-SC4H3)(mu-P(C4H3S)2)] (5) resulting from carbon-sulfur bond scission and carbon-hydrogen bond formation and containing a ring-opened mu3-eta3-1-thia-1,3-butadiene ligand. In contrast, a similar thermolysis of 3 affords the phosphinidene cluster [Ru3(CO)7(mu-dppm)(mu3-eta2-C4H2O)(mu3-P(C4H3O))] (7) resulting from a second phosphorus-carbon bond cleavage and (presumably) elimination of furan. Treatment of 4 and 6 with PPh3 affords the simple phosphine-substituted products [Ru3(CO)6(PPh3)(mu-dppm)(mu3-eta2-C4H2E)(mu-P(C4H3E)2)(mu-H)] (E = S, 8; E = O, 9). Both thiophyne and furyne clusters 4 and 6 readily react with hydrogen bromide to give [Ru3(CO)6Br(mu-Br)(mu-dppm)(mu3-eta2-eta1-C4H2E)(mu-P(C4H3E)2)(mu-H)] (E = S, 10; E = O, 11) containing both terminal and bridging bromides. Here the alkynes bind in a highly unsymmetrical manner with one carbon acting as a bridging alkylidene and the second as a terminally bonded Fisher carbene. As far as we are aware, this binding mode has only previously been noted in ynamine complexes or those with metals in different oxidation states. The crystal structures of seven of these new triruthenium clusters have been carried out, allowing a detailed analysis of the relative orientations of coordinated ligands.
Garrison, Virginia H.; Foreman, William T.; Genualdi, Susan A.; Majewski, Michael S.; Mohammed, Azad; Simonich, Staci Massey
2011-01-01
Every year, billions of tons of fine particles are eroded from the surface of the Sahara Desert and the Sahel of West Africa, lifted into the atmosphere by convective storms, and transported thousands of kilometers downwind. Most of the dust is carried west to the Americas and the Caribbean in the Saharan Air Layer (SAL). Dust air masses predominately impact northern South America during the Northern Hemisphere winter and the Caribbean and Southeastern United States in summer. Dust concentrations vary considerably temporally and spatially. In a dust source region (Mali), concentrations range from background levels of 575 micrograms per cubic meter (mu/u g per m3) to 13,000 mu/u g per m3 when visibility degrades to a few meters (Gillies and others, 1996). In the Caribbean, concentrations of 200 to 600 mu/u g per m3 in the mid-Atlantic and Barbados (Prospero and others, 1981; Talbot and others, 1986), 3 to 20 mu/u g per m3 in the Caribbean (Prospero and Nees, 1986; Perry and others, 1997); and >100 mu/u g per m3 in the Virgin Islands (this dataset) have been reported during African dust conditions. Mean dust particle size decreases as the SAL traverses from West Africa to the Caribbean and Americas as a result of gravitational settling. Mean particle size reaching the Caribbean is <1 micrometer (mu/u m) (Perry and others, 1997), and even finer particles are carried into Central America, the Southeastern United States, and maritime Canada. Particles less than 2.5 mu/u m diameter (termed PM2.5) can be inhaled deeply into human lungs. A large body of literature has shown that increased PM2.5 concentrations are linked to increased cardiovascular/respiratory morbidity and mortality (for example, Dockery and others, 1993; Penn and others, 2005).
Ide, Yasuhiro; Shibahara, Takashi
2007-01-22
A seven-electron cluster [Mo3(mu3-S){mu3-SC(CO(2)CH(3))=C(CO(2)CH(3))S}{mu-SC(CO(2)CH(3))=CH(CO(2)CH(3))}(dtp)3(mu-OAc)] [2, S2P(OC(2)H(5))2-; dtp = diethyldithiophosphate] and an organometallic cluster [Mo3(mu3-S){mu3-SC(CO(2)CH(3))=C(CO(2)CH(3))S}{mu-SC(CO(2)CH(3))CH(OCH(3))(CO2)}(dtp)2(CH(3)OH)(mu-OAc)](Mo-C) (3) were obtained by reaction in methanol of the sulfur-bridged trinuclear complex [Mo3(mu3-S)(mu-S)3(dtp)3(CH(3)CN)(mu-OAc)] (1) with dimethylacetylenedicarboxylate (DMAD). The X-ray structures of 2 and 3 revealed the adduct formation of two DMAD molecules to the respective Mo(3)S(4) cores. 2 is paramagnetic and obeys the Curie-Weiss law: the mu(eff) value at 300 K is 1.90 muB. The electron spin resonance signal was observed at 173 K. The density functional theory calculation of 2 demonstrated that the main components of the singly occupied molecular orbitals of alpha and beta spins are Mo d electrons and the main components of lowest unoccupied molecular orbitals are of Mo and the olefin moiety with one C-S bond. A one-electron reversible oxidation process of 2 was observed at E1/2 = -0.11 V vs Fc/Fc+. The electronic spectrum of 2 has a peak at 468 nm (epsilon = 2170 M(-1) cm(-1)) and shoulders at 640 (918) and 797 (605) nm, and 3 has shoulders at 441 (1740) and 578 (625) nm and a distinct peak at 840 (467) nm. An intermediate [Mo3(mu3-S){mu3-SC(CO(2)CH(3))=C(CO(2)CH(3))S}{mu-SC(CO(2)CH(3))=CH(CO(2)CH(3))}(dtp)3(mu-OAc)]+ (4) is tentatively suggested: a one-electron reduction of 4 gives 2, and a nucleophilic conjugate addition of CH(3)O- to the alpha,beta-unsaturated carbonyl group of 4 gives 3.
Sirunyan, Albert M; et al.
2017-08-25
Normalized differential cross sections for top quark pair production are measured in the dilepton (emore » $^+$e$^-$, $$\\mu^+\\mu^-$$, and $$\\mu^\\mp$$e$$^\\pm$$) decay channels in proton-proton collisions at a center-of-mass energy of 13 TeV. The measurements are performed with data corresponding to an integrated luminosity of 2.1 fb$$^{-1}$$ using the CMS detector at the LHC. The cross sections are measured differentially as a function of the kinematic properties of the leptons, jets from bottom quark hadronization, top quarks, and top quark pairs at the particle and parton levels. The results are compared to several Monte Carlo generators that implement calculations up to next-to-leading order in perturbative quantum chromodynamics interfaced with parton showering, and also to fixed-order theoretical calculations of top quark pair production up to next-to-next-to-leading order.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sharma, Anil Kumar; Supe, Sanjay S.; Anantha, N.
2015-01-15
Accuracy of dose delivery at low monitor unit setting is studied for a dual photon energy linear accelerator. Dose delivered per MU is found to be constant for both the photon beams for MU settings above 30. For lower MUs there is definite deviation from the calibrated value and the error is found to be increasing as fewer MUs are set for dose delivery. This dose/MU ratio at low MU setting is found to be dose-rate dependent, showing an increasing trend with pulse repetition frequency (PRF). Also, the dosimetric ratio is observed to be mode dependent; its value for anmore » 18 MV beam is almost double that observed in the case of a 6 MV beam at very low MU setting. The magnitude of this error should be determined for each energy so that appropriate corrections can be applied if very low MUs are to be used.« less
Nagashima, Yuji; Matsumoto, Takuya; Kadoyama, Keisuke; Ishizaki, Shoichiro; Terayama, Makoto
2011-01-01
Green toadfish Lagocephalus lunaris inhabits tropical and subtropical seas and contains high tetrodotoxin (TTX) levels in the muscle as well as liver and gonad. In 2008 to 2009, food poisoning due to ingesting L. lunais occurred in Western Japan. Five specimens of green toadfish caught in Kyushu coast, Japan, were analyzed for toxicity, toxins, and species identification. All five specimens were toxic by bioassay. Comparing the maximum toxicity in tissues, ovary contained the most toxin (1810 mouse unit [MU]/g), followed by liver (341 MU/g), muscle (135 MU/g), skin (79 MU/g), and intestine (72 MU/g). Liquid chromatography/mass spectrometry analysis revealed that TTX was the major toxin. Nucleotide sequence analysis of the 16S rRNA gene fragment of muscle mitochondrial DNA indicated that partial sequences of PCR products of four specimens were identical with that of L. lunaris. The sequence of one specimen was indistinguishable from that of the brown-backed toadfish Lagocephalus wheeleri, a nontoxic species. PMID:22028709
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baldassare, J.J.; Henderson, P.A.; Fisher, G.J.
1989-01-10
The effects of thrombin and GTP{gamma}S on the hydrolysis of phosphoinositides by membrane-associated phospholipase C (PLC) from human platelets were examined with endogenous ({sup 3}H)inositol-labeled membranes or with lipid vesicles containing either ({sup 3}H)phosphatidylinositol or ({sup 3}H)phosphatidylinositol 4,5-bisphosphate. GTP{gamma}S (1 {mu}M) or thrombin (1 unit/mL) did not stimulate release of inositol trisphosphate (IP{sub 3}), inositol bisphosphate (IP{sub 2}), or inositol phosphate (IP) from ({sup 3}H)inositol-labeled membranes. IP{sub 2} and IP{sub 3}, but not IP, from ({sup 3}H)inositol-labeled membranes were, however, stimulated 3-fold by GTP{gamma}S (1 {mu}M) plus thrombin (1 unit/mL). A higher concentration of GTP{gamma}S (100 {mu}M) alone also stimulatedmore » IP{sub 2} and IP{sub 3}, but not IP, release. In the presence of 1 mM calcium, release of IP{sub 2} and IP{sub 3} was increased 6-fold over basal levels; however, formation of IP was not observed. At submicromolar calcium concentration, hydrolysis of exogenous phosphatidylinositol 4,5-bisphosphate (PIP{sub 2}) by platelet membrane associated PLC was also markedly enhanced by GTP{gamma}S (100 {mu}M) or GTP{gamma}S (1 {mu}M) plus thrombin (1 unit/mL). Under identical conditions, exogenous phosphatidylinositol (PI) was not hydrolyzed. The same substrate specificity was observed when the membrane-associated PLC was activated with 1 mM calcium. Thrombin-induced hydrolysis of PIP{sub 2} was inhibited by treatment of the membranes with pertussis toxin or pretreatment of intact platelets with 12-O-tetradecanoyl-13-acetate (TPA) prior to preparation of membranes. Pertussis toxin did not inhibit GTP{gamma}S (100 {mu}M) or calcium (1 mM) dependent PIP{sub 2} breakdown, while TPA inhibited GTP{gamma}S-dependent but not calcium-dependent phospholipase C activity.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Janjua, Naveed Zafar; Department of Community Health Sciences, Aga Khan University, Karachi; Delzell, Elizabeth
Objectives: To estimate the umbilical cord blood lead levels (BLLs) of Pakistani neonates and to identify determinants for umbilical BLLs. Methods: We conducted a cross-sectional study of mothers and infants at one of the two obstetric units of two tertiary care hospitals in Karachi during January-August 2005. Information from 540 mothers selected randomly from those registered for delivery was obtained about their pregnancy, diet, and current and past lead exposures. We collected umbilical cord blood for lead levels analyzed using graphite furnace atomic absorption spectrophotometry. We computed geometric and arithmetic means. We performed multiple linear regression analysis to identify factorsmore » associated with log-transformed umbilical cord BLLs. We also performed logistic regression analysis to identify determinants of high lead cord BLLs ({>=}10 {mu}g/dl). Results: The geometric mean cord BLL of the neonates was 9.6 {mu}g/dl; arithmetic mean (S.D.) was 10.8 {mu}g/dl (5.7) with a median of 9.7 {mu}g/dl and a range of 1.8-48.9 {mu}g/dl. Women who reported intake of less than 58.5 mg of elemental iron supplement per day during pregnancy had cord BLL of 10.0 {mu}g/dl; in comparison those women who had higher iron intake had lower cord BLL (8.4 {mu}g/dl). Those who used surma (an eye cosmetic) daily had higher cord BLL (11.5 {mu}g/dl) as compared to those who used it less frequently (9.4 {mu}g/dl). In multivariable linear regression model, higher iron intake, owning a car, and being in 2nd quartile of mid-arm circumference were associated with low lead levels while father's occupation in lead-based industry was associated with significantly higher umbilical cord BLLs. There was interaction of daily surma use and ethnicity. Geometric mean BLLs were varied among surma users by ethnicity. Conclusions: Umbilical cord BLLs are high in Karachi, Pakistan, in comparison to those in developed countries such as United States. Measures are needed to reduce fetal lead exposure to prevent adverse affect on neurocognitive development. Association of low iron (below RDA of 60 mg per day) with high umbilical cord has implications for strengthening iron supplement intake during pregnancy. Umbilical cord BLLs differed among surma users by ethnicity.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Howard, M; Beltran, C; Herman, M
Purpose: To investigate the influence of the minimum monitor unit (MU) on the quality of clinical treatment plans for scanned proton therapy. Methods: Delivery system characteristics limit the minimum number of protons that can be delivered per spot, resulting in a min-MU limit. Plan quality can be impacted by the min-MU limit. Two sites were used to investigate the impact of min-MU on treatment plans: pediatric brain tumor at a depth of 5-10 cm; a head and neck tumor at a depth of 1-20 cm. Three field intensity modulated spot scanning proton plans were created for each site with themore » following parameter variations: min-MU limit range of 0.0000-0.0060; and spot spacing range of 0.5-2.0σ of the nominal spot size at isocenter in water (σ=4mm in this work). Comparisons were based on target homogeneity and normal tissue sparing. Results: The increase of the min-MU with a fixed spot spacing decreases plan quality both in homogeneous target coverage and in the avoidance of critical structures. Both head and neck and pediatric brain plans show a 20% increase in relative dose for the hot spot in the CTV and 10% increase in key critical structures when comparing min-MU limits of 0.0000 and 0.0060 with a fixed spot spacing of 1σ. The DVHs of CTVs show min-MU limits of 0.0000 and 0.0010 produce similar plan quality and quality decreases as the min-MU limit increases beyond 0.0020. As spot spacing approaches 2σ, degradation in plan quality is observed when no min-MU limit is imposed. Conclusion: Given a fixed spot spacing of ≤ 1σ of the spot size in water, plan quality decreases as min- MU increases greater than 0.0020. The effect of min-MU should be taken into consideration while planning spot scanning proton therapy treatments to realize its full potential.« less
SU-F-T-564: 3 Year Experience of Treatment Plan QualityAssurance for Vero SBRT Patients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Su, Z; Li, Z; Mamalui, M
2016-06-15
Purpose: To verify treatment plan monitor units from iPlan treatment planning system for Vero Stereotactic Body Radiotherapy (SBRT) treatment using both software-based and (homogeneous and heterogeneous) phantom-based approaches. Methods: Dynamic conformal arcs (DCA) were used for SBRT treatment of oligometastasis patients using Vero linear accelerator. For each plan, Monte Carlo calculated treatment plans MU (prescribed dose to water with 1% variance) is verified first by RadCalc software with 3% difference threshold. Beyond 3% differences, treatment plans were copied onto (homogeneous) Scanditronix phantom for non-lung patients and copied onto (heterogeneous) CIRS phantom for lung patients and the corresponding plan dose wasmore » measured using a cc01 ion chamber. The difference between the planed and measured dose was recorded. For the past 3 years, we have treated 180 patients with 315 targets. Out of these patients, 99 targets treatment plan RadCalc calculation exceeded 3% threshold and phantom based measurements were performed with 26 plans using Scanditronix phantom and 73 plans using CIRS phantom. Mean and standard deviation of the dose differences were obtained and presented. Results: For all patient RadCalc calculations, the mean dose difference is 0.76% with a standard deviation of 5.97%. For non-lung patient plan Scanditronix phantom measurements, the mean dose difference is 0.54% with standard deviation of 2.53%; for lung patient plan CIRS phantom measurements, the mean dose difference is −0.04% with a standard deviation of 1.09%; The maximum dose difference is 3.47% for Scanditronix phantom measurements and 3.08% for CIRS phantom measurements. Conclusion: Limitations in secondary MU check software lead to perceived large dose discrepancies for some of the lung patient SBRT treatment plans. Homogeneous and heterogeneous phantoms were used in plan quality assurance for non-lung patients and lung patients, respectively. Phantom based QA showed the relative good agreement between iPlan calculated dose and measured dose.« less
Crystallization and preliminary X-ray analysis of gene product 44 from bacteriophage Mu
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kondou, Youhei; Faculty of Pharmaceutical Sciences, Toyama Medical and Pharmaceutical University, Toyama; Kitazawa, Daisuke
2005-01-01
Bacteriophage Mu baseplate protein gene product 44 was crystallized. The crystal belongs to space group R3, with unit-cell parameters a = b = 126.6, c = 64.2 Å. Bacteriophage Mu baseplate protein gene product 44 (gp44) is an essential protein required for the assembly of viable phages. To investigate the roles of gp44 in baseplate assembly and infection, gp44 was crystallized at pH 6.0 in the presence of 20% 2-methyl-2,4-pentanediol. The crystals belong to space group R3, with unit-cell parameters a = b = 127.47, c = 63.97 Å. The crystals diffract X-rays to at least 2.1 Å resolution andmore » are stable in the X-ray beam and are therefore appropriate for structure determination. Native data have been collected to 2.1 Å resolution using a DIP6040 image-plate system at beamline BL44XU at the SPring-8 facility in Japan.« less
Njeh, Christopher F; Salmon, Howard W; Schiller, Claire
2017-01-01
Intensity-modulated radiation therapy (IMRT) delivery using "step-and-shoot" technique on Varian C-Series linear accelerator (linac) is influenced by the communication frequency between the multileaf collimator and linac controllers. Hence, the dose delivery accuracy is affected by the dose rate. Our aim was to quantify the impact of using two dose rates on plan quality assurance (QA). Twenty IMRT patients were selected for this study. The plan QA was measured at two different dose rates. A gamma analysis was performed, and the degree of plan modulation on the QA pass rate was also evaluated in terms of average monitor unit per segment (MU/segment) and the total number of segments. The mean percentage gamma pass rate of 94.9% and 93.5% for 300 MU/min and 600 MU/min dose rate, respectively, was observed. There was a significant ( P = 0.001) decrease in percentage gamma pass rate when the dose rate was increased from 300 MU/min to 600 MU/min. There was a weak, but significant association between the percentage pass rate at both dose rate and total number of segments. The total number of MU was significantly correlated to the total number of segments ( r = 0.59). We found a positive correlation between the percentage pass rate and mean MU/segment, r = 0.52 and r = 0.57 for 300 MU/min and 600 MU/min, respectively. IMRT delivery using step-and-shoot technique on Varian 2300CD is impacted by the dose rate and the total amount of segments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duan, F.K.; Liu, X.D.; He, K.B.
2009-03-15
The total nitrogen (TN) and water-soluble nitrogenous ions were determined by using CHN Elemental Analyzer and ion chromatography method, respectively, from November 24, 1998 to February 12, 1999 in Beijing. The average concentrations of TN, NH{sub 4}{sup +} and NO{sub 3}{sup -} were 10.62 {mu} g N m{sup -3}, 6.67 {mu} g m{sup -3} and 10.01 {mu} g m{sup -3}, respectively. The total inorganic nitrogen (IN) calculated from NH{sub 4}{sup +} and NO{sub 3}{sup -} was 7.45 {mu} g N m{sup -3}, accounting for 70% of TN, i.e., 30% of TN existed as organic nitrogen form (ON). The correlation betweenmore » ON and other pollution tracers showed that, coal combustion, biomass burning, soil humic matter and secondary formation were the important sources of ON in particulate matter in Beijing.« less
Optical analysis of cirrhotic liver by near infrared time resolved spectroscopy
NASA Astrophysics Data System (ADS)
Nishio, Toshihiro; Kitai, Toshiyuki; Miwa, Mitsuharu; Takahashi, Rei; Yamaoka, Yoshio
1999-10-01
The severity of liver cirrhosis was related with the optical properties of liver tissue. Various grades of liver cirrhosis were produced in rats by intraperitoneal injection of thioacetamide (TAA) for different periods: 4 weeks, 8 weeks, 12 weeks, and 16 weeks. Optical properties of the liver, absorption, coefficient ((mu) a) and scattering coefficient (microsecond(s) '), were measured by near-infrared time- resolved spectroscopy. Histological examination confirmed cirrhotic changes in the liver, which were more severe in rats with TAA administration for longer periods. The (mu) a increased in 4- and 8-week rats, and then decreased in 12- and 16-week rats. The (mu) a of blood-free liver decreased as liver cirrhosis progressed. The hemoglobin content in the liver calculated from the (mu) a values increased in 4- and 8-week rats and decreased in 12- and 16-week rats. The microsecond(s) ' decreased in the cirrhotic liver, probably reflecting the decrease in the mitochondria content. It was shown that (mu) a and microsecond(s) ' determination is useful to assess the severity of liver cirrhosis.
Observational constraints for C-rich AGB stars
NASA Astrophysics Data System (ADS)
Rau, G.; Hron, J.; Paladini, C.; Aringer, B.; Marigo, P.; Eriksson, K.
We modeled the atmospheres of six carbon-rich Asymptotic Giant Branch stars (R Lep, R Vol, Y Pav, AQ Sgr, U Hya, and X TrA) using VLTI/MIDI interferometric observations, together with spectro-photometric data, we compared them with self-consistent, dynamic model atmospheres. The results show that the models can reproduce the Spectral Energy Distribution (SED) data well at wavelengths longer than 1 mu m, and the interferometric observations between 8 mu m and 10 mu m. We found differences at wavelengths shorter than 1 mu m in the SED, and longer than 10 mu m in the visibilities. The discrepancies observed can be explained in terms of a combination of data- and model-related reasons. We derived some stellar parameters, and our findings agree well with literature values within the uncertainties. Also, when comparing the location of the stars in the H-R diagram, with evolutionary tracks, the results show that the main derived properties (L, Teff, C/O ratios and stellar masses) from the model fitting are in good agreement with TP-AGB evolutionary calculations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Younker, J.M.; Krest, C.M.; Jiang, W.
2009-05-28
The class Ic ribonucleotide reductase from Chlamydia trachomatis (C{bar A}) uses a stable Mn(lV)/ Fe(lll) cofactor to initiate nucleotide reduction by a free-radical mechanism. Extended X-ray absorption fine structure (EXAFS) spectroscopy and density functional theory (DFT) calculations are used to postulate a structure for this cofactor. Fe and Mn K-edge EXAFS data yield an intermetallic distance of -2.92 {angstrom}. The Mn data also suggest the presence of a short 1.74 {angstrom} Mn-O bond. These metrics are compared to the results of DFT calculations on 12 cofactor models derived from the crystal structure of the inactive Fe2(lll/ III) form of themore » protein. Models are differentiated by the protonation states of their bridging and terminal OH{sub x} ligands as well as the location of the Mn(lV) ion (site 1 or 2). The models that agree best with experimental observation feature a{mu}-1, 3-carboxylate bridge (E120), terminal solvent (H{sub 2}O/OH) to site 1, one {mu}-O bridge, and one {mu}-OH bridge. The site-placement of the metal ions cannot be discerned from the available data.« less
Contribution of uranium to gross alpha radioactivity in some environmental samples in Kuwait
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bou-Rabee, F.; Bakir, Y.; Bem, H.
1995-08-01
This study was done in connection with the use of uranium-tipped antitank shells during the Gulf War and possible contamination of the environment of Kuwait. It was found that uranium concentrations in the soil samples ranged from 0.3 {mu}g/g to 1.85 {mu}g/g. The average value of 0.7 {mu}g/g was lower than the world average value of 2.1 {mu}g/g for surface soils. Its contribution to the total natural alpha radioactivity (excluding Rn and its short-lived daughters) varied from 1.1% to 14%. The solid fall-out samples showed higher uranium concentration which varied from 0.35 {mu}g/g to 1.73 {mu}/g (average 1.47 {mu}g/g) butmore » its contribution to the gross alpha radioactivity was in the same range, from 1.1 to 13.2%. The difference in the concentration of uranium in suspended air matter samples during the summer of 1993 and the winter of 1994 was found to be 2.0 {mu}g/g and 1.0 {mu}g/g, respectively. The uranium contribution to the natural alpha radioactivity in these samples was in the same range but lower for the winter period. The isotopic ratio of {sup 235}U to {sup 238}U for the measured samples was basically within an experimental error of {+-}0.001, close to the theoretical value of 0.007. The calculated total annual intake of uranium via inhalation for the Kuwait population was 0.07 Bq, e.g., 0.2% of the annual limit on intake. 13 refs., 1 fig., 3 tabs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Howard, Michelle, E-mail: howard.michelle1@mayo.edu; Beltran, Chris; Mayo, Charles S.
Purpose: To investigate the influence of the minimum monitor unit (MU) on the quality of clinical treatment plans for scanned proton therapy. Methods: Delivery system characteristics limit the minimum number of protons that can be delivered per spot, resulting in a min-MU limit. Plan quality can be impacted by the min-MU limit. Two sites were used to investigate the impact of min-MU on treatment plans: pediatric brain tumor at a depth of 5–10 cm; a head and neck tumor at a depth of 1–20 cm. Three-field, intensity modulated spot scanning proton plans were created for each site with the followingmore » parameter variations: min-MU limit range of 0.0000–0.0060; and spot spacing range of 2–8 mm. Comparisons were based on target homogeneity and normal tissue sparing. For the pediatric brain, two versions of the treatment planning system were also compared to judge the effects of the min-MU limit based on when it is accounted for in the optimization process (Eclipse v.10 and v.13, Varian Medical Systems, Palo Alto, CA). Results: The increase of the min-MU limit with a fixed spot spacing decreases plan quality both in homogeneous target coverage and in the avoidance of critical structures. Both head and neck and pediatric brain plans show a 20% increase in relative dose for the hot spot in the CTV and 10% increase in key critical structures when comparing min-MU limits of 0.0000 and 0.0060 with a fixed spot spacing of 4 mm. The DVHs of CTVs show min-MU limits of 0.0000 and 0.0010 produce similar plan quality and quality decreases as the min-MU limit increases beyond 0.0020. As spot spacing approaches 8 mm, degradation in plan quality is observed when no min-MU limit is imposed. Conclusions: Given a fixed spot spacing of ≤4 mm, plan quality decreases as min-MU increased beyond 0.0020. The effect of min-MU needs to be taken into consideration while planning proton therapy treatments.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rao, M; Chen, F; Cotrutz, C
2015-06-15
Purpose: To investigate the influence of respiratory motion on the delivered dose in lung stereotactic body radiotherapy (SBRT) using Cyberknife (CK) 0-View tracking mode. Methods: CT scans at inspiration and expiration of an anthropomorphic motion phantom were fused base on the spine and an internal target volume (ITV) was created. A 5mm expansion around the ITV resulted in the planning target volume. Three CK plans were generated in Accuray MultiPlan using Lung Optimization Tracking 0-View technique with the minimum MU per beam set to (a) 5MU, (b) 15MU and (c) 30MU, respectively. Doses were calculated on the expiration CT usingmore » Monte-Carlo algorithm. Each plan was delivered 5 times with a range of different starting phases in the respiratory cycle to assess the dose variation due to interplay effect. The delivered dose was measured with EBT3 Gafchromic film which was inserted in the moving target of the phantom. The target motion range is 3 cm in superior-inferior (SI) direction with the breathing period of 5 seconds. Results: The gamma analysis (5%/2mm) of the dose with the films in the transverse plane resulted in average passing rate of 95.5±4.1%, 96.7±2.6%, and 96.2±2.5% for plan (a), (b), and (c), respectively. For the sagittal films, the average passing rate was 91.1±4.9%, 92.1±3.6%, and 92.3±2.9% for the three plans, respectively. The disagreement between measurement and dose calculations were mostly on the target edges in SI direction. The mean measured versus calculated dose differences at the edge of target in SI direction were (a) 3.9±4.8%, (b) 2.4±3.3%, and (c) 2.2±3.2% for the three plans, respectively. Conclusions: The plans with low-MU beams (below 10MU) tend to cause slightly larger dose variation. However in terms of target coverage, the overall clinical dosimetric impact of the intrafraction respiratory motion in lung SBRT is insignificant when averaged over 3∼5 fractions.« less
Meaningful use of health information technology and declines in in-hospital adverse drug events.
Furukawa, Michael F; Spector, William D; Rhona Limcangco, M; Encinosa, William E
2017-07-01
Nationwide initiatives have promoted greater adoption of health information technology as a means to reduce adverse drug events (ADEs). Hospital adoption of electronic health records with Meaningful Use (MU) capabilities expected to improve medication safety has grown rapidly. However, evidence that MU capabilities are associated with declines in in-hospital ADEs is lacking. Data came from the 2010-2013 Medicare Patient Safety Monitoring System and the 2008-2013 Healthcare Information and Management Systems Society (HIMSS) Analytics Database. Two-level random intercept logistic regression was used to estimate the association of MU capabilities and occurrence of ADEs, adjusting for patient characteristics, hospital characteristics, and year of observation. Rates of in-hospital ADEs declined by 19% from 2010 to 2013. Adoption of MU capabilities was associated with 11% lower odds of an ADE (95% confidence interval [CI], 0.84-0.96). Interoperability capability was associated with 19% lower odds of an ADE (95% CI, 0.67- 0.98). Adoption of MU capabilities explained 22% of the observed reduction in ADEs, or 67,000 fewer ADEs averted by MU. Concurrent with the rapid uptake of MU and interoperability, occurrence of in-hospital ADEs declined significantly from 2010 to 2013. MU capabilities and interoperability were associated with lower occurrence of ADEs, but the effects did not vary by experience with MU. About one-fifth of the decline in ADEs from 2010 to 2013 was attributable to MU capabilities. Findings support the contention that adoption of MU capabilities and interoperability spurred by the Health Information Technology for Economic and Clinical Health Act contributed in part to the recent decline in ADEs. Published by Oxford University Press on behalf of the American Medical Informatics Association 2017. This work is written by US Government employees and is in the public domain in the United States.
Dalton, Gulliver T; Viau, Lydie; Waterman, Susan M; Humphrey, Mark G; Bruce, Michael I; Low, Paul J; Roberts, Rachel L; Willis, Anthony C; Koutsantonis, George A; Skelton, Brian W; White, Allan H
2005-05-02
Reaction of [WIr3(mu-CO)3(CO)8(eta-C5Me5)] (1c) with [W(C[triple bond]CPh)(CO)3(eta-C5H5)] afforded the edge-bridged tetrahedral cluster [W2Ir3(mu4-eta2-C2Ph)(mu-CO)(CO)9(eta-C5H5)(eta-C5Me5)] (3) and the edge-bridged trigonal-bipyramidal cluster [W3Ir3(mu4-eta2-C2Ph)(mu-eta2-C=CHPh)(Cl)(CO)8(eta-C5Me5)(eta-C5H5)2] (4) in poor to fair yield. Cluster 3 forms by insertion of [W(C[triple bond]CPh)(CO)3(eta-C5H5)] into Ir-Ir and W-Ir bonds, accompanied by a change in coordination mode from a terminally bonded alkynyl to a mu4-eta2 alkynyl ligand. Cluster 4 contains an alkynyl ligand interacting with two iridium atoms and two tungsten atoms in a mu4-eta2 fashion, as well as a vinylidene ligand bridging a W-W bond. Reaction of [WIr3(CO)11(eta-C5H5)] (1a) or 1c with [(eta-C5H5)(CO)2 Ru(C[triple bond]C)Ru(CO)2(eta-C5H5)] afforded [Ru2WIr3(mu5-eta2-C2)(mu-CO)3(CO)7(eta-C5H5)2(eta-C5R5)] [R = H (5a), Me (5c)] in low yield, a structural study of 5a revealing a WIr3 butterfly core capped and spiked by Ru atoms; the diruthenium ethyndiyl precursor has undergone Ru-C scission, with insertion of the C2 unit into a W-Ir bond of the cluster precursor. Reaction of [W2Ir2(CO)10(eta-C5H5)2] with the diruthenium ethyndiyl reagent gave [RuW2Ir2{mu4-eta2-(C2C[triple bond]C)Ru(CO)2(eta-C5H5)}(mu-CO)2(CO)6(eta-C5H5)3] (6) in low yield, a structural study of 6 revealing a butterfly W2Ir2 unit capped by a Ru(eta-C5H5) group resulting from Ru-C scission; the terminal C2 of a new ruthenium-bound butadiyndiyl ligand has been inserted into the W-Ir bond. Reaction between 1a, [WIr3(CO)11(eta-C5H4Me)] (1b), or 1c and [(eta-C5H5)(CO)3W(C[triple bond]CC[triple bond]C)W(CO)3(eta-C5H5)] afforded [W2Ir3{mu4-eta2-(C2C[triple bond]C)W(CO)3(eta-C5H5)}(mu-CO)2(CO)2(eta-C5H5)(eta-C5R5)] [R = H (7a), Me (7c); R5 = H4Me (7b)] in good yield, a structural study of 7c revealing it to be a metallaethynyl analogue of 3.
Hu, Xiaogang; Suresh, Aneesha K; Rymer, William Z; Suresh, Nina L
2016-08-01
Hemispheric stroke survivors often show impairments in voluntary muscle activation. One potential source of these impairments could come from altered control of muscle, via disrupted motor unit (MU) firing patterns. In this study, we sought to determine whether MU firing patterns are modified on the affected side of stroke survivors, as compared with the analogous contralateral muscle. Using a novel surface electromyogram (EMG) sensor array, coupled with advanced template recognition software (dEMG) we recorded surface EMG signals over the first dorsal interosseous (FDI) muscle on both paretic and contralateral sides. Recordings were made as stroke survivors produced isometric index finger abductions over a large force range (20%-60% of maximum). Utilizing the dEMG algorithm, MU firing rates, recruitment thresholds, and action potential amplitudes were estimated for concurrently active MUs in each trial. Our results reveal significant changes in the firing rate patterns in paretic FDI muscle, in that the discharge rates, characterized in relation to recruitment force threshold and to MU size, were less clearly correlated with recruitment force than in contralateral FDI muscles. Firing rates in the affected muscle also did not modulate systematically with the level of voluntary muscle contraction, as would be expected in intact muscles. These disturbances in firing properties also correlated closely with the impairment of muscle force generation. Our results provide strong evidence of disruptions in MU firing behavior in paretic muscles after a hemispheric stroke, suggesting that modified control of the spinal motoneuron pool could be a contributing factor to muscular weakness in stroke survivors.
Sleep/wake firing patterns of human genioglossus motor units.
Bailey, E Fiona; Fridel, Keith W; Rice, Amber D
2007-12-01
Although studies of the principal tongue protrudor muscle genioglossus (GG) suggest that whole muscle GG electromyographic (EMG) activities are preserved in nonrapid eye movement (NREM) sleep, it is unclear what influence sleep exerts on individual GG motor unit (MU) activities. We characterized the firing patterns of human GG MUs in wakefulness and NREM sleep with the aim of determining 1) whether the range of MU discharge patterns evident in wakefulness is preserved in sleep and 2) what effect the removal of the "wakefulness" input has on the magnitude of the respiratory modulation of MU activities. Microelectrodes inserted into the extrinsic tongue protrudor muscle, the genioglossus, were used to follow the discharge of single MUs. We categorized MU activities on the basis of the temporal relationship between the spike train and the respiration cycle and quantified the magnitude of the respiratory modulation of each MU using the eta (eta(2)) index, in wakefulness and sleep. The majority of MUs exhibited subtle increases or decreases in respiratory modulation but were otherwise unaffected by NREM sleep. In contrast, 30% of MUs exhibited marked sleep-associated changes in discharge frequency and respiratory modulation. We suggest that GG MUs should not be considered exclusively tonic or phasic; rather, the discharge pattern appears to be a flexible feature of GG activities in healthy young adults. Whether such flexibility is important in the response to changes in the chemical and/or mechanical environment and whether it is preserved as a function of aging or in individuals with obstructive sleep apnea are critical questions for future research.
NASA Astrophysics Data System (ADS)
Hu, Xiaogang; Suresh, Aneesha K.; Rymer, William Z.; Suresh, Nina L.
2016-08-01
Objective. Hemispheric stroke survivors often show impairments in voluntary muscle activation. One potential source of these impairments could come from altered control of muscle, via disrupted motor unit (MU) firing patterns. In this study, we sought to determine whether MU firing patterns are modified on the affected side of stroke survivors, as compared with the analogous contralateral muscle. Approach. Using a novel surface electromyogram (EMG) sensor array, coupled with advanced template recognition software (dEMG) we recorded surface EMG signals over the first dorsal interosseous (FDI) muscle on both paretic and contralateral sides. Recordings were made as stroke survivors produced isometric index finger abductions over a large force range (20%-60% of maximum). Utilizing the dEMG algorithm, MU firing rates, recruitment thresholds, and action potential amplitudes were estimated for concurrently active MUs in each trial. Main results. Our results reveal significant changes in the firing rate patterns in paretic FDI muscle, in that the discharge rates, characterized in relation to recruitment force threshold and to MU size, were less clearly correlated with recruitment force than in contralateral FDI muscles. Firing rates in the affected muscle also did not modulate systematically with the level of voluntary muscle contraction, as would be expected in intact muscles. These disturbances in firing properties also correlated closely with the impairment of muscle force generation. Significance. Our results provide strong evidence of disruptions in MU firing behavior in paretic muscles after a hemispheric stroke, suggesting that modified control of the spinal motoneuron pool could be a contributing factor to muscular weakness in stroke survivors.
Carcass Functions in Variational Calculations for Few-Body Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Donchev, A.G.; Kalachev, S.A.; Kolesnikov, N.N.
For variational calculations of molecular and nuclear systems involving a few particles, it is proposed to use carcass basis functions that generalize exponential and Gaussian trial functions. It is shown that the matrix elements of the Hamiltonian are expressed in a closed form for a Coulomb potential, as well as for other popular particle-interaction potentials. The use of such carcass functions in two-center Coulomb problems reduces, in relation to other methods, the number of terms in a variational expansion by a few orders of magnitude at a commensurate or even higher accuracy. The efficiency of the method is illustrated bymore » calculations of the three-particle Coulomb systems {mu}{mu}e, ppe, dde, and tte and the four-particle molecular systems H{sub 2} and HeH{sup +} of various isotopic composition. By considering the example of the {sub {lambda}}{sup 9}Be hypernucleus, it is shown that the proposed method can be used in calculating nuclear systems as well.« less
Beuthan, J; Cappius, H J; Hielscher, A; Hopf, M; Klose, A; Netz, U
2001-11-01
Rheumatoid arthritis affecting the small joints--in particular the fingers--has advantageous geometry for the transmission of near-infrared (NIR) light. Examination of the optical properties of tissues has revealed that as a result of changes to the capsule and synovial fluid there is a considerable increase in photon scattering already in the early stages of the disease--in particular around 685 nm. This suggests the appropriateness of analysing the photon density profile resulting from punctiform irradiation of the joint. In a first approximation, the point spread function of transmitted photon density is confirmed to be proportional to a Gauss distribution, as suggested by Arridge. In accordance with the linear signal transfer theory, therefore, it is possible to establish a virtual transfer system described by a first-order differential equation. (The tissue optical conditions mu a < mu's and mu a = constant (mu a = absorption coefficient) were assumed). The parameter mu's (= reduced scattering coefficient) was determined by linear approximation of the Gauss distribution to the calculated or measured point spread function. For selected patient data, the mu's was determined in healthy and diseased finger joints (e.g. 10.1 cm-1 and 26.8 cm-1, respectively), and the results were in good agreement with those obtained experimentally.
Assessing Unit-Price Related Remifentanil Choice in Rhesus Monkeys
ERIC Educational Resources Information Center
Galuska, Chad M.; Winger, Gail; Woods, James H.; Hursh, Steven R.
2006-01-01
Given a commodity available at different prices, a unit-price account of choice predicts preference for the cheaper alternative. This experiment determined if rhesus monkeys preferred remifentanil (an ultra-short-acting [mu]-opioid agonist) delivered at a lower unit price over a higher-priced remifentanil alternative (Phases 1 and 3). Choice…
Aerosol penetration through a model transport system: Comparison of theory and experiment
DOE Office of Scientific and Technical Information (OSTI.GOV)
McFarland, A.R.; Wong, F.S.; Anand, N.K.
1991-09-01
Numerical predictions were made of aerosol penetration through a model transport system. A physical model of the system was constructed and tested in an aerosol wind tunnel to obtain comparative data. The system was 26.6 mm in diameter and consisted of an inlet and three straight sections (oriented horizontally, vertically, and at 45{degree}). Particle sizes covered a range in which losses were primarily caused by inertial and gravitational effects (3-25 {mu}m aerodynamic equivalent diameter (AED)). Tests were conducted at two flow rates (70 and 130 l/min) and two inlet orientations (parallel and perpendicular to the free stream). Wind speed wasmore » 3 m/s for all test cases. The cut points for aerosol penetration through the experimental model vis-a-vis the numerical results are as follows: At a flow rate of 70 l/min with the inlet at 0{degree}, the experimentally observed cut point was 16.2 {mu}m AED while the numerically predicted value was 18.2 {mu}m AED while the numerically predicted value was 18.2 {mu}m AED. At 130 l/min and 0{degree}, the experimental cut point was 12.8 {mu}m AED as compared with a numerically value of 13.7 {mu}m AED. At 70l/min and a 90{degree}, the experimental cut point was 12.0 {mu}m AED while the numerically calculated value was 11.1 {mu}m AED. Slopes of the experimental penetration curves are somewhat steeper than the numerically predicted counterparts.« less
NASA Astrophysics Data System (ADS)
Aldegunde, J.; Jambrina, P. G.; García, E.; Herrero, V. J.; Sáez-Rábanos, V.; Aoiz, F. J.
2013-11-01
The advent of very precise measurements of rate coefficients in reactions of muonium (Mu), the lightest hydrogen isotope, with H2 in its ground and first vibrational state and of kinetic isotope effects with respect to heavier isotopes has triggered a renewed interests in the field of muonic chemistry. The aim of the present article is to review the most recent results about the dynamics and mechanism of the reaction Mu+H2 to shed light on the importance of quantum effects such as tunnelling, the preservation of the zero point energy, and the vibrational adiabaticity. In addition to accurate quantum mechanical (QM) calculations, quasiclassical trajectories (QCT) have been run in order to check the reliability of this method for this isotopic variant. It has been found that the reaction with H2(v=0) is dominated by the high zero point energy (ZPE) of the products and that tunnelling is largely irrelevant. Accordingly, both QCT calculations that preserve the products' ZPE as well as those based on the Ring Polymer Molecular Dynamics methodology can reproduce the QM rate coefficients. However, when the hydrogen molecule is vibrationally excited, QCT calculations fail completely in the prediction of the huge vibrational enhancement of the reactivity. This failure is attributed to tunnelling, which plays a decisive role breaking the vibrational adiabaticity when v=1. By means of the analysis of the results, it can be concluded that the tunnelling takes place through the ν1=1 collinear barrier. Somehow, the tunnelling that is missing in the Mu+H2(v=0) reaction is found in Mu+H2(v=1).
Kato, Merii; Sah, Ajay Kumar; Tanase, Tomoaki; Mikuriya, Masahiro
2006-08-21
Tetranuclear copper(II) complexes containing alpha-D-glucose-1-phosphate (alpha-D-Glc-1P), [Cu4(mu-OH){mu-(alpha-D-Glc-1P)}2(bpy)4(H2O)2]X3 [X = NO3 (1a), Cl (1b), Br (1c)], and [Cu4(mu-OH){mu-(alpha-D-Glc-1P)}2(phen)4(H2O)2](NO3)3 (2) were prepared by reacting the copper(II) salt with Na2[alpha-D-Glc-1P] in the presence of diimine ancillary ligands, and the structure of 2 was characterized by X-ray crystallography to comprise four {Cu(phen)}2+ fragments connected by the two sugar phosphate dianions in 1,3-O,O' and 1,1-O mu4-bridging fashion as well as a mu-hydroxo anion. The crystal structure of 2 involves two chemically independent complex cations in which the C2 enantiomeric structure for the trapezoidal tetracopper(II) framework is switched according to the orientation of the alpha-D-glucopyranosyl moieties. Temperature-dependent magnetic susceptibility data of 1a indicated that antiferromagnetic spin coupling is operative between the two metal ions joined by the hydroxo bridge (J = -52 cm(-1)) while antiferromagnetic interaction through the Cu-O-Cu sugar phosphate bridges is weak (J = -13 cm(-1)). Complex 1a readily reacted with carboxylic acids to afford the tetranuclear copper(II) complexes, [Cu4{mu-(alpha-D-Glc-1P)}2(mu-CA)2(bpy)4](NO3)2 [CA = CH3COO (3), o-C6H4(COO)(COOH) (4)]. Reactions with m-phenylenediacetic acid [m-C6H4(CH2COOH)2] also gave the discrete tetracopper(II) cationic complex [Cu4{mu-(alpha-D-Glc-1P)}2(mu-m-C6H4(CH2COO)(CH2COOH))2(bpy)4](NO3)2 (5a) as well as the cluster polymer formulated as {[Cu4{mu-(alpha-D-Glc-1P)}2(mu-m-C6H4(CH2COO)2)(bpy)4](NO3)2}n (5b). The tetracopper structure of 1a is converted into a symmetrical rectangular core in complexes 3, 4, and 5b, where the hydroxo bridge is dissociated and, instead, two carboxylate anions bridge another pair of Cu(II) ions in a 1,1-O monodentate fashion. The similar reactions were applied to incorporate sugar acids onto the tetranuclear copper(II) centers. Reactions of 1a with delta-D-gluconolactone, D-glucuronic acid, or D-glucaric acid in dimethylformamide resulted in the formation of discrete tetracopper complexes with sugar acids, [Cu4{mu-(alpha-D-Glc-1P)}2(mu-SA)2(bpy)4](NO3)2 [SA = D-gluconate (6), D-glucuronate (7), D-glucarateH (8a)]. The structures of 6 and 7 were determined by X-ray crystallography to be almost identical with that of 3 with additional chelating coordination of the C-2 hydroxyl group of D-gluconate moieties (6) or the C-5 cyclic O atom of D-glucuronate units (7). Those with D-glucaric acid and D-lactobionic acid afforded chiral one-dimensional polymers, {[Cu4{mu-(alpha-D-Glc-1P)}2(mu-D-glucarate)(bpy)4](NO3)2}n (8b) and {[Cu4{mu-(alpha-D-Glc-1P)}2(mu-D-lactobionate)(bpy)4(H2O)2](NO3)3}n (9), respectively, in which the D-Glc-1P-bridged tetracopper(II) units are connected by sugar acid moieties through the C-1 and C-6 carboxylate O atoms in 8b and the C-1 carboxylate and C-6 alkoxy O atoms of the gluconate chain in 9. When complex 7 containing d-glucuronate moieties was heated in water, the mononuclear copper(II) complex with 2-dihydroxy malonate, [Cu(mu-O2CC(OH)2CO2)(bpy)] (10), and the dicopper(II) complex with oxalate, [Cu2(mu-C2O4)(bpy)2(H2O)2](NO3)2 (11), were obtained as a result of oxidative degradation of the carbohydrates through C-C bond cleavage reactions.
Absolute dose calculations for Monte Carlo simulations of radiotherapy beams.
Popescu, I A; Shaw, C P; Zavgorodni, S F; Beckham, W A
2005-07-21
Monte Carlo (MC) simulations have traditionally been used for single field relative comparisons with experimental data or commercial treatment planning systems (TPS). However, clinical treatment plans commonly involve more than one field. Since the contribution of each field must be accurately quantified, multiple field MC simulations are only possible by employing absolute dosimetry. Therefore, we have developed a rigorous calibration method that allows the incorporation of monitor units (MU) in MC simulations. This absolute dosimetry formalism can be easily implemented by any BEAMnrc/DOSXYZnrc user, and applies to any configuration of open and blocked fields, including intensity-modulated radiation therapy (IMRT) plans. Our approach involves the relationship between the dose scored in the monitor ionization chamber of a radiotherapy linear accelerator (linac), the number of initial particles incident on the target, and the field size. We found that for a 10 x 10 cm2 field of a 6 MV photon beam, 1 MU corresponds, in our model, to 8.129 x 10(13) +/- 1.0% electrons incident on the target and a total dose of 20.87 cGy +/- 1.0% in the monitor chambers of the virtual linac. We present an extensive experimental verification of our MC results for open and intensity-modulated fields, including a dynamic 7-field IMRT plan simulated on the CT data sets of a cylindrical phantom and of a Rando anthropomorphic phantom, which were validated by measurements using ionization chambers and thermoluminescent dosimeters (TLD). Our simulation results are in excellent agreement with experiment, with percentage differences of less than 2%, in general, demonstrating the accuracy of our Monte Carlo absolute dose calculations.
Copper in the intake and discharge zones of the Surry and Salem Nuclear Power Stations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harrison, F.L.; Bishop, D.J.; Rice, D.W. Jr.
Copper concentrations were measured in the soluble and particulate fractions of water samples and bedload sediments collected in intake and discharge areas of the Surry and Salem Nuclear Power Stations during normal operations. Additional samples of water and suspended particles were collected during startup of Unit 2 at the Salem Power Station. In water samples collected from Surry, total copper ranged from 6.5 to 24.7 and labile copper from 0.5 to 2.9 ..mu..g/L; in those from Salem, total copper ranged from 6.7 to 10.6 and labile from 0.9 to 3.8 ..mu..g/L. At both sites the highest total copper concentration wasmore » measured in January 1979 during a period of high runoff. In general, differences between influent and effluent waters were small; the maximum was 4.2 ..mu..g Cu/L. Copper concentration in the water during startup of Unit 2 of Salem was high initially (>2500 ..mu..g Cu/L) but was almost entirely in the particulate fraction; labile copper was only 0.6 ..mu..g/L. The apparent complexing capacity (ACC) of the waters from Surry ranged from 6 to 40 and those from Salem from 5 to 60 ..mu..g Cu/L. Ranges in dissolved organic carbon were smaller, 2.9 to 5.1 and 2.2 to 5.0 mg C/L for Surry and Salem, respectively, and showed no relationship with ACC. Ultrafiltration of discharge waters indicated that, in most samples, the largest fraction of copper in the untreated water was in the >10,000 <100,000 molecular weight fraction; in waters treated to destroy dissolved organic carbon, it was generally in the >100,000 molecular weight fraction.Copper concentrations in intact bedload sediments from the intake area of Surry ranged from 2.3 to 26 and of Salem from 36 to 74 ..mu..g/g dry weight; those in the discharge area of Surry ranged from 13 to 30 and of Salem from 3 to 67. We noted considerable spatial heterogeneity both at the intake and discharge areas, and higher copper concentrations in the <62-..mu..m fraction than in intact sediments.« less
NASA Technical Reports Server (NTRS)
Bortner, M. H.; Alyea, F. N.; Grenda, R. N.; Liebling, G. R.; Levy, G. M.
1973-01-01
The feasibility of measuring atmospheric carbon monoxide from a remote platform using the correlation interferometry technique was considered. It has been determined that CO data can be obtained with an accuracy of 10 percent using this technique on the first overtone band of CO at 2.3 mu. That band has been found to be much more suitable than the stronger fundamental band at 4.6 mu. Calculations for both wavelengths are presented which illustrate the effects of atmospheric temperature profiles, inversion layers, ground temperature and emissivity, CO profile, reflectivity, and atmospheric pressure. The applicable radiative transfer theory on which these calculations are based is described together with the principles of the technique.
Zheng, Jianyong; Wei, Wei; Lan, Xing; Zhang, Yinjun; Wang, Zhao
2018-05-15
This study describes a sensitive and fluorescent microplate assay method to detect lipase transesterification activity. Lipase-catalyzed transesterification between butyryl 4-methyl umbelliferone (Bu-4-Mu) and methanol in tert-butanol was selected as the model reaction. The release of 4-methylumbelliferone (4-Mu) in the reaction was determined by detecting the fluorescence intensity at λ ex 330 nm and λ em 390 nm. Several lipases were used to investigate the accuracy and efficiency of the proposed method. Apparent Michaelis constant (Km) was calculated for transesterification between Bu-4-Mu and methanol by the lipases. The main advantages of the assay method include high sensitivity, inexpensive reagents, and simple detection process. Copyright © 2018 Elsevier Inc. All rights reserved.
Root-Bernstein, Robert; Turke, Miah; Subhramanyam, Udaya K Tiruttani; Churchill, Beth; Labahn, Joerg
2018-01-17
Extensive evidence demonstrates functional interactions between the adrenergic and opioid systems in a diversity of tissues and organs. While some effects are due to receptor and second messenger cross-talk, recent research has revealed an extracellular, allosteric opioid binding site on adrenergic receptors that enhances adrenergic activity and its duration. The present research addresses whether opioid receptors may have an equivalent extracellular, allosteric adrenergic binding site that has similar enhancing effects on opioid binding. Comparison of adrenergic and opioid receptor sequences revealed that these receptors share very significant regions of similarity, particularly in some of the extracellular and transmembrane regions associated with adrenergic binding in the adrenergic receptors. Five of these shared regions from the mu opioid receptor (muOPR) were synthesized as peptides and tested for binding to adrenergic, opioid and control compounds using ultraviolet spectroscopy. Adrenergic compounds bound to several of these muOPR peptides with low micromolar affinity while acetylcholine, histamine and various adrenergic antagonists did not. Similar studies were then conducted with purified, intact muOPR with similar results. Combinations of epinephrine with methionine enkephalin or morphine increased the binding of both by about half a log unit. These results suggest that muOPR may be allosterically enhanced by adrenergic agonists.
Passariello, Annalisa; Terrin, Gianluca; Baldassarre, Maria E; Bisceglia, Massimo; Ruotolo, Serena; Berni Canani, Roberto
2010-08-01
The prevalence and severity of atopic manifestations in children are increasing in western countries in the last decades. Specific nutritional intervention may prevent or delay the onset of atopic diseases in infants at high risk of developing allergy. These nutritional interventions should be applied early in the perinatal period to have a chance of success. Thus, we assessed adherence to the dietary management recommendations of the Committee on Nutrition and Section on Allergy and Immunology of the American Academy of Pediatrics (AAP) for the prevention of atopic diseases in neonatal age through an audit study. Questionnaire was administered to the chiefs of 30 maternity units (MU) with more than 1500 live births/yr to report the policy applied in their MU. Twenty-two MU returned the questionnaire. Identification of high-risk newborns was routinely performed only in 7/22 MU (31.8%). High-risk newborns were identified by the presence of at least two or one first-degree relative (parent or sibling) with documented allergic disease by 18.2% and 45.5% of MU, respectively. Specific maternal dietary restrictions during lactation were adopted in 7/22 MU (31.8%). Extensively or partially hydrolyzed formula was prescribed for bottle-fed high-risk infants in 22.7% of MU. Only 2/22 MU have a policy in complete agreement with the nutritional intervention proposed by the AAP. Our study suggest a poor adherence to dietary recommendations for primary prevention of atopic disease in neonatology clinical practice. Further efforts should be planned to improve the knowledge and the application of these preventive strategies.
Martinez-Valdes, Eduardo; Negro, Francesco; Falla, Deborah; De Nunzio, Alessandro Marco; Farina, Dario
2018-04-01
Surface electromyographic (EMG) signal amplitude is typically used to compare the neural drive to muscles. We experimentally investigated this association by studying the motor unit (MU) behavior and action potentials in the vastus medialis (VM) and vastus lateralis (VL) muscles. Eighteen participants performed isometric knee extensions at four target torques [10, 30, 50, and 70% of the maximum torque (MVC)] while high-density EMG signals were recorded from the VM and VL. The absolute EMG amplitude was greater for VM than VL ( P < 0.001), whereas the EMG amplitude normalized with respect to MVC was greater for VL than VM ( P < 0.04). Because differences in EMG amplitude can be due to both differences in the neural drive and in the size of the MU action potentials, we indirectly inferred the neural drives received by the two muscles by estimating the synaptic inputs received by the corresponding motor neuron pools. For this purpose, we analyzed the increase in discharge rate from recruitment to target torque for motor units matched by recruitment threshold in the two muscles. This analysis indicated that the two muscles received similar levels of neural drive. Nonetheless, the size of the MU action potentials was greater for VM than VL ( P < 0.001), and this difference explained most of the differences in EMG amplitude between the two muscles (~63% of explained variance). These results indicate that EMG amplitude, even following normalization, does not reflect the neural drive to synergistic muscles. Moreover, absolute EMG amplitude is mainly explained by the size of MU action potentials. NEW & NOTEWORTHY Electromyographic (EMG) amplitude is widely used to compare indirectly the strength of neural drive received by synergistic muscles. However, there are no studies validating this approach with motor unit data. Here, we compared between-muscles differences in surface EMG amplitude and motor unit behavior. The results clarify the limitations of surface EMG to interpret differences in neural drive between muscles.
SU-E-T-76: A Software System to Monitor VMAT Plan Complexity in a Large Radiotherapy Centre
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arumugam, S; Xing, A; Ingham Institute, Sydney, NSW
2015-06-15
Purpose: To develop a system that analyses and reports the complexity of Volumetric Modulated Arc Therapy (VMAT) plans to aid in the decision making for streamlining patient specific dosimetric quality assurance (QA) tests. Methods: A software system, Delcheck, was developed in-house to calculate VMAT plan and delivery complexity using the treatment delivery file. Delcheck has the functionality to calculate multiple plan complexity metrics including the Li-Xing Modulation Index (LI-MI), multiplicative combination of Leaf Travel and Modulation Complexity Score (LTMCSv), Monitor Units per prescribed dose (MU/D) and the delivery complexity index (MIt) that incorporates the modulation of dose rate, leaf speedmore » and gantry speed. Delcheck includes database functionality to store and compare plan metrics for a specified treatment site. The overall plan and delivery complexity is assessed based on the 95% conformance limit of the complexity metrics as Similar, More or Less complex. The functionality of the software was tested using 42 prostate conventional, 10 prostate SBRT and 15 prostate bed VMAT plans generated for an Elekta linear accelerator. Results: The mean(σ) of LI-MI for conventional, SBRT and prostate bed plans were 1690(486), 3215.4(1294) and 3258(982) respectively. The LTMCSv of the studied categories were 0.334(0.05), 0.325(0.07) and 0.3112(0.09). The MU/D of the studied categories were 2.4(0.4), 2.7(0.7) and 2.5(0.5). The MIt of the studied categories were 21.6(3.4), 18.2(3.0) and 35.9(6.6). The values of the complexity metrics show that LI-MI appeared to resolve the plan complexity better than LTMCSv and MU/D. The MIt value increased as the delivery complexity increased. Conclusion: The developed software was shown to be working as expected. In studied treatment categories Prostate bed plans are more complex in both plan and delivery and SBRT is more complex in plan and less complex in delivery as demonstrated by LI-MI and MIt. This project was funded through a Cancer Council NSW Project Grant (RG14-11)« less
Determination of the Neutron Magnetic Moment
DOE R&D Accomplishments Database
Greene, G. L.; Ramsey, N. F.; Mampe, W.; Pendlebury, J. M.; Smith, K.; Dress, W. B.; Miller, P. D.; Perrin, P.
1981-06-01
The neutron magnetic moment has been measured with an improvement of a factor of 100 over the previous best measurement. Using a magnetic resonance spectrometer of the separated oscillatory field type capable of determining a resonance signal for both neutrons and protons (in flowing H{sub 2}O), we find ..mu..{sub n}/..mu..{sub p} = 0.68497935(17) (0.25 ppM). The neutron magnetic moment can also be expressed without loss of accuracy in a variety of other units.
Hawking radiation, covariant boundary conditions, and vacuum states
DOE Office of Scientific and Technical Information (OSTI.GOV)
Banerjee, Rabin; Kulkarni, Shailesh
2009-04-15
The basic characteristics of the covariant chiral current
Martinez‐Valdes, E.; Negro, F.; Laine, C. M.; Falla, D.; Mayer, F.
2017-01-01
Key points Classic motor unit (MU) recording and analysis methods do not allow the same MUs to be tracked across different experimental sessions, and therefore, there is limited experimental evidence on the adjustments in MU properties following training or during the progression of neuromuscular disorders.We propose a new processing method to track the same MUs across experimental sessions (separated by weeks) by using high‐density surface electromyography.The application of the proposed method in two experiments showed that individual MUs can be identified reliably in measurements separated by weeks and that changes in properties of the tracked MUs across experimental sessions can be identified with high sensitivity.These results indicate that the behaviour and properties of the same MUs can be monitored across multiple testing sessions.The proposed method opens new possibilities in the understanding of adjustments in motor unit properties due to training interventions or the progression of pathologies. Abstract A new method is proposed for tracking individual motor units (MUs) across multiple experimental sessions on different days. The technique is based on a novel decomposition approach for high‐density surface electromyography and was tested with two experimental studies for reliability and sensitivity. Experiment I (reliability): ten participants performed isometric knee extensions at 10, 30, 50 and 70% of their maximum voluntary contraction (MVC) force in three sessions, each separated by 1 week. Experiment II (sensitivity): seven participants performed 2 weeks of endurance training (cycling) and were tested pre–post intervention during isometric knee extensions at 10 and 30% MVC. The reliability (Experiment I) and sensitivity (Experiment II) of the measured MU properties were compared for the MUs tracked across sessions, with respect to all MUs identified in each session. In Experiment I, on average 38.3% and 40.1% of the identified MUs could be tracked across two sessions (1 and 2 weeks apart), for the vastus medialis and vastus lateralis, respectively. Moreover, the properties of the tracked MUs were more reliable across sessions than those of the full set of identified MUs (intra‐class correlation coefficients ranged between 0.63—0.99 and 0.39–0.95, respectively). In Experiment II, ∼40% of the MUs could be tracked before and after the training intervention and training‐induced changes in MU conduction velocity had an effect size of 2.1 (tracked MUs) and 1.5 (group of all identified motor units). These results show the possibility of monitoring MU properties longitudinally to document the effect of interventions or the progression of neuromuscular disorders. PMID:28032343
TU-AB-BRC-12: Optimized Parallel MonteCarlo Dose Calculations for Secondary MU Checks
DOE Office of Scientific and Technical Information (OSTI.GOV)
French, S; Nazareth, D; Bellor, M
Purpose: Secondary MU checks are an important tool used during a physics review of a treatment plan. Commercial software packages offer varying degrees of theoretical dose calculation accuracy, depending on the modality involved. Dose calculations of VMAT plans are especially prone to error due to the large approximations involved. Monte Carlo (MC) methods are not commonly used due to their long run times. We investigated two methods to increase the computational efficiency of MC dose simulations with the BEAMnrc code. Distributed computing resources, along with optimized code compilation, will allow for accurate and efficient VMAT dose calculations. Methods: The BEAMnrcmore » package was installed on a high performance computing cluster accessible to our clinic. MATLAB and PYTHON scripts were developed to convert a clinical VMAT DICOM plan into BEAMnrc input files. The BEAMnrc installation was optimized by running the VMAT simulations through profiling tools which indicated the behavior of the constituent routines in the code, e.g. the bremsstrahlung splitting routine, and the specified random number generator. This information aided in determining the most efficient compiling parallel configuration for the specific CPU’s available on our cluster, resulting in the fastest VMAT simulation times. Our method was evaluated with calculations involving 10{sup 8} – 10{sup 9} particle histories which are sufficient to verify patient dose using VMAT. Results: Parallelization allowed the calculation of patient dose on the order of 10 – 15 hours with 100 parallel jobs. Due to the compiler optimization process, further speed increases of 23% were achieved when compared with the open-source compiler BEAMnrc packages. Conclusion: Analysis of the BEAMnrc code allowed us to optimize the compiler configuration for VMAT dose calculations. In future work, the optimized MC code, in conjunction with the parallel processing capabilities of BEAMnrc, will be applied to provide accurate and efficient secondary MU checks.« less
Equivalent ZF precoding scheme for downlink indoor MU-MIMO VLC systems
NASA Astrophysics Data System (ADS)
Fan, YangYu; Zhao, Qiong; Kang, BoChao; Deng, LiJun
2018-01-01
In indoor visible light communication (VLC) systems, the channels of photo detectors (PDs) at one user are highly correlated, which determines the choice of spatial diversity model for individual users. In a spatial diversity model, the signals received by PDs belonging to one user carry the same information, and can be combined directly. Based on the above, we propose an equivalent zero-forcing (ZF) precoding scheme for multiple-user multiple-input single-output (MU-MIMO) VLC systems by transforming an indoor MU-MIMO VLC system into an indoor multiple-user multiple-input single-output (MU-MISO) VLC system through simply processing. The power constraints of light emitting diodes (LEDs) are also taken into account. Comprehensive computer simulations in three scenarios indicate that our scheme can not only reduce the computational complexity, but also guarantee the system performance. Furthermore, the proposed scheme does not require noise information in the calculating of the precoding weights, and has no restrictions on the numbers of APs and PDs.
NASA Astrophysics Data System (ADS)
Ishihara, Koichi; Asai, Yusuke; Kudo, Riichi; Ichikawa, Takeo; Takatori, Yasushi; Mizoguchi, Masato
2013-12-01
Multiuser multiple-input multiple-output (MU-MIMO) has been proposed as a means to improve spectrum efficiency for various future wireless communication systems. This paper reports indoor experimental results obtained for a newly developed and implemented downlink (DL) MU-MIMO orthogonal frequency division multiplexing (OFDM) transceiver for gigabit wireless local area network systems in the microwave band. In the transceiver, the channel state information (CSI) is estimated at each user and fed back to an access point (AP) on a real-time basis. At the AP, the estimated CSI is used to calculate the transmit beamforming weight for DL MU-MIMO transmission. This paper also proposes a recursive inverse matrix computation scheme for computing the transmit weight in real time. Experiments with the developed transceiver demonstrate its feasibility in a number of indoor scenarios. The experimental results clarify that DL MU-MIMO-OFDM transmission can achieve a 972-Mbit/s transmission data rate with simple digital signal processing of single-antenna users in an indoor environment.
Sanuki, Tetsuji; Yumoto, Eiji; Nishimoto, Kohei; Minoda, Ryosei
2014-04-01
To assess laryngeal muscle activity in unilateral vocal fold paralysis (UVFP) patients using laryngeal electromyography (LEMG) and coronal images. Case series with chart review. University hospital. Twenty-one patients diagnosed with UVFP of at least 6 months in duration with paralytic dysphonia, underwent LEMG, phonatory function tests, and coronal imaging. A 4-point scale was used to grade motor unit (MU) recruitment: absent = 4+, greatly decreased = 3+, moderately decreased = 2+, and mildly decreased = 1+. Maximum phonation time (MPT) and mean flow rate (MFR) were employed. Coronal images were assessed for differences in thickness and vertical position of the vocal folds during phonation and inhalation. MU recruitment in thyroarytenoid/lateral cricoarytenoid (TA/LCA) muscle complex results were 1+ for 4 patients, 2+ for 5, 3+ for 6, and 4+ for 6. MPT was positively correlated with MU recruitment. Thinning of the affected fold was evident during phonation in 19 of the 21 subjects. The affected fold was at an equal level with the healthy fold in all 9 subjects with MU recruitment of 1+ and 2+. Eleven of 12 subjects with MU recruitments of 3+ and 4+ showed the affected fold at a higher level than the healthy fold. There was a significant difference between MU recruitment and the vertical position of the affected fold. Synkinetic reinnervation may occur in some cases with UVFP. MU recruitments of TA/LCA muscle complex in UVFP patients may be related to phonatory function and the vertical position of the affected fold.
Strangeness spin, magnetic moment, and strangeness configurations of the proton
DOE Office of Scientific and Technical Information (OSTI.GOV)
An, C.S.; Riska, D.O.; Zou, B.S.
2006-03-15
The implications of the empirical signatures for the positivity of the strangeness magnetic moment {mu}{sub s} and the negativity of the strangeness contribution to the proton spin {delta}{sub s} on the possible uudss configurations of five quarks in the proton are analyzed. The empirical signs for the values for these two observables can only be obtained in configurations where the uuds subsystem is orbitally excited and the s antiquark is in the ground state. The configurations in which the s is orbitally excited, including the conventional K{sup +}{lambda}{sup 0} configuration, with the exception of that in which the uuds componentmore » has spin 2, yield negative values for {mu}{sub s}. Here, the strangeness spin {delta}{sub s}, strangeness magnetic moment {mu}{sub s}, and axial coupling constant G{sub A}{sup s} are calculated for all possible configurations of the uudss component of the proton. In the configuration with [4]{sub FS}[22]{sub F}[22]{sub S} flavor-spin symmetry, which is likely to have the lowest energy, {mu}{sub s} is positive and {delta}{sub s}{approx_equal}G{sub A}{sup s}{approx_equal}-1/3{mu}{sub s}.« less
Aging reduces experience-induced sensorimotor plasticity. A magnetoencephalographic study.
Mary, Alison; Bourguignon, Mathieu; Wens, Vincent; Op de Beeck, Marc; Leproult, Rachel; De Tiège, Xavier; Peigneux, Philippe
2015-01-01
Modulation of the mu-alpha and mu-beta spontaneous rhythms reflects plastic neural changes within the primary sensorimotor cortex (SM1). Using magnetoencephalography (MEG), we investigated how aging modifies experience-induced plasticity after learning a motor sequence, looking at post- vs. pre-learning changes in the modulation of mu rhythms during the execution of simple hand movements. Fifteen young (18-30 years) and fourteen older (65-75 years) right-handed healthy participants performed auditory-cued key presses using all four left fingers simultaneously (Simple Movement task - SMT) during two separate sessions. Following both SMT sessions, they repeatedly practiced a 5-elements sequential finger-tapping task (FTT). Mu power calculated during SMT was averaged across 18 gradiometers covering the right sensorimotor region and compared before vs. after sequence learning in the alpha (9/10/11Hz) and the beta (18/20/22Hz) bands separately. Source power maps in the mu-alpha and mu-beta bands were localized using Dynamic Statistical Parametric Mapping (dSPM). The FTT sequence was performed faster at retest than at the end of the learning session, indicating an offline boost in performance. Analyses conducted on SMT sessions revealed enhanced rebound after learning in the right SM1, 3000-3500ms after the initiation of movement, in young as compared to older participants. Source reconstruction indicated that mu-beta is located in the precentral gyrus (motor processes) and mu-alpha is located in the postcentral gyrus (somatosensory processes) in both groups. The enhanced post-movement rebound in young subjects potentially reflects post-training plastic changes in SM1. Age-related decreases in post-training modulatory effects suggest reduced experience-dependent plasticity in the aging brain. Copyright © 2014 Elsevier Inc. All rights reserved.
NOTE: A practical approach for electron monitor unit calculation
NASA Astrophysics Data System (ADS)
Choi, David; Patyal, Baldev; Cho, Jongmin; Cheng, Ing Y.; Nookala, Prashanth
2009-08-01
Electron monitor unit (MU) calculation requires measured beam data such as the relative output factor (ROF) of a cone, insert correction factor (ICF) and effective source-to-surface distance (ESD). Measuring the beam data to cover all possible clinical cases is not practical for a busy clinic because it takes tremendous time and labor. In this study, we propose a practical approach to reduce the number of data measurements without affecting accuracy. It is based on two findings of dosimetric properties of electron beams. One is that the output ratio of two inserts is independent of the cone used, and the other is that ESD is a function of field size but independent of cone and jaw opening. For the measurements to prove the findings, a parallel plate ion chamber (Markus, PTW 23343) with an electrometer (Cardinal Health 35040) was used. We measured the outputs to determine ROF, ICF and ESD of different energies (5-21 MeV). Measurements were made in a Plastic Water™ phantom or in water. Three linear accelerators were used: Siemens MD2 (S/N 2689), Siemens Primus (S/N 3305) and Varian Clinic 21-EX (S/N 1495). With these findings, the number of data set to be measured can be reduced to less than 20% of the data points.
Ahamed, Shabbir; Singh, Navin; Gudipudi, Deleep; Mulinti, Suneetha; Talluri, Anil; Soubhagya, Bhudevi; Sresty, Madhusudhana
2017-03-01
To quantify relative merit of MU deprived plans against freely optimized plans in terms of plan quality and report changes induced by progressive resolution optimizer algorithm (PRO3) to the dynamic parameters of RapidArc. Ten cases of carcinoma hypopharynx were retrospectively planned in three phases without using MU tool. Replicas of these baseline plans were reoptimized using "Intermediate dose" feature and "MU tool" to reduce MUs by 20%, 35%, and 50%. Overall quality indices for target and OAR, integral dose, dose-volume spread were assessed. All plans were appraised for changes induced in RapidArc dynamic parameters and pre-treatment quality assurance (QA). With increasing MU reduction strength (MURS), MU/Gy values reduced, for all phases with an overall range of 8.6-34.7%; mean dose rate decreased among plans of each phase, phase3 plans recorded greater reductions. MURS20% showed good trade-off between MUs and plan quality. Dose-volume spread below 5Gy was higher for baseline plans while lower between 20 and 35Gy. Integral dose was lower for MURS0%, not exceeding 1.0%, compared against restrained plans. Mean leaf aperture and control point areas increased systematically, correlated negatively with increasing MURS. Absolute delta dose rate variations were least for MURS0%. MU deprived plans exhibited GAI (>93%), better than MURS0% plans. Baseline plans are superior to MU restrained plans. However, MURS20% offers equivalent and acceptable plan quality with mileage of MUs, improved GAI for complex cases. MU tool may be adopted to tailor treatment plans using PRO3. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Mechanistic investigations of imine hydrogenation catalyzed by dinuclear iridium complexes.
Martín, Marta; Sola, Eduardo; Tejero, Santiago; López, José A; Oro, Luis A
2006-05-15
Treatment of [Ir2(mu-H)(mu-Pz)2H3(NCMe)(PiPr3)2] (1) with one equivalent of HBF4 or [PhNH=CHPh]BF4 affords efficient catalysts for the homogeneous hydrogenation of N-benzylideneaniline. The reaction of 1 with HBF4 leads to the trihydride-dihydrogen complex [Ir2(mu-H)(mu-Pz)2H2(eta2-H2)(NCMe)(PiPr3)2]BF4 (2), which has been characterized by NMR spectroscopy and DFT calculations on a model complex. Complex 2 reacts with imines such as tBuN=CHPh or PhN=CHPh to afford amine complexes [Ir2(mu-H)(mu-Pz)2H2(NCMe){L}(PiPr3)2]BF4 (L = NH(tBu)CH2Ph, 3; NH(Ph)CH2Ph, 4) through a sequence of proton- and hydride-transfer steps. Dihydrogen partially displaces the amine ligand of 4 to form 2; this complements a possible catalytic cycle for the N-benzylideneaniline hydrogenation in which the amine-by-dihydrogen substitution is the turnover-determining step. The rates of ligand substitution in 4 and its analogues with labile ligands other than amine are dependent upon the nature of the leaving ligand and independent on the incoming ligand concentration, in agreement with dissociative substitutions. Water complex [Ir2(mu-H)(mu-Pz)2H2(NCMe)(OH2)(PiPr3)2]BF4 (7) hydrolyzes N-benzylideneaniline, which eventually affords the poor hydrogenation catalyst [Ir2(mu-H)(mu-Pz)2H2(NCMe)(NH2Ph)(PiPr3)2]BF4 (11). The rate law for the catalytic hydrogenation in 1,2-dichloroethane with complex [Ir2(mu-H)(mu-Pz)2H2(OSO2CF3)(NCMe)(PiPr3)2] (8) as catalyst precursor is rate = k[8]{p(H2)}; this is in agreement with the catalytic cycle deduced from the stochiometric experiments. The hydrogenation reaction takes place at a single iridium center of the dinuclear catalyst, although ligand modifications at the neighboring iridium center provoke changes in the hydrogenation rate. Even though this catalyst system is also capable of effectively hydrogenating alkenes, N-benzylideneaniline can be selectively hydrogenated in the presence of simple alkenes.
Associated Electron-Muon Events from High-Energy Hadronic Collisions
NASA Astrophysics Data System (ADS)
Plaag, Robert Emil
The inclusive reaction p + N (--->) e + (mu) + X was measured at an energy of 38.8 GeV (center of mass). Data representing a total luminosity of 13.4 inverse femtobarns (13.4 x 10('39) cm('-2)) were analyzed. Three associated electron-muon events were observed. The observed signal was 0.02 (+OR-) 0.015 of the Drell-Yan di-muon production. The expected number of e(mu) events from tau lepton pair production and decay was calculated to be 0.5 (+OR-) 0.1. A two sigma upper limit for (lepton family number violating) two body resonant decays to e + (mu) was obtained (<0.020 (+OR-) 0.015 x (sigma)(,Drell-Yan) for masses above 7 GeV at 0.95 C.L.) and interpreted with a physi- cally reasonable model. No prompt e(mu) events attributable to charm production and decay, or bottom production and decay, were seen. This corresponded to a two sigma upper limit for charm pair produc- tion of <300 x (sigma)(,Drell-Yan) for pair masses above 11 GeV. In terms of an absolute cross section, this production limit is <200 picobarn for charm pair masses above 11 GeV. On the other band, the momenta of the three candidate events suggested a possible e('(+OR-))K('(-OR+)) source that acted as a non-prompt source of e(mu) events. A p + N (--->) D + (')D (--->) e + K (--->) e + (mu) interpretation of these candidate events was consistent with the lower limit on charm production obtained with the prompt e(mu) rate.
Why Do Calculators Have Rubber Feet?
ERIC Educational Resources Information Center
Heavers, Richard M.
2007-01-01
Our students like using the covers of their TI graphing calculators in an inquiry-based extension of a traditional exercise that challenges their preconceived ideas about friction. Biology major Fiona McGraw (Fig. 1) is obviously excited about the large coefficient of static friction ([mu][subscript s] = 1.3) for the four little rubber feet on her…
Turke, Miah; Subhramanyam, Udaya K. Tiruttani; Churchill, Beth; Labahn, Joerg
2018-01-01
Extensive evidence demonstrates functional interactions between the adrenergic and opioid systems in a diversity of tissues and organs. While some effects are due to receptor and second messenger cross-talk, recent research has revealed an extracellular, allosteric opioid binding site on adrenergic receptors that enhances adrenergic activity and its duration. The present research addresses whether opioid receptors may have an equivalent extracellular, allosteric adrenergic binding site that has similar enhancing effects on opioid binding. Comparison of adrenergic and opioid receptor sequences revealed that these receptors share very significant regions of similarity, particularly in some of the extracellular and transmembrane regions associated with adrenergic binding in the adrenergic receptors. Five of these shared regions from the mu opioid receptor (muOPR) were synthesized as peptides and tested for binding to adrenergic, opioid and control compounds using ultraviolet spectroscopy. Adrenergic compounds bound to several of these muOPR peptides with low micromolar affinity while acetylcholine, histamine and various adrenergic antagonists did not. Similar studies were then conducted with purified, intact muOPR with similar results. Combinations of epinephrine with methionine enkephalin or morphine increased the binding of both by about half a log unit. These results suggest that muOPR may be allosterically enhanced by adrenergic agonists. PMID:29342106
Frère, Julien; Göpfert, Beat; Slawinski, Jean; Tourny-Chollet, Claire
2012-04-01
This study aimed at determining the upper limb muscles coordination during a power backward giant swing (PBGS) and the recruitment pattern of motor units (MU) of co-activated muscles. The wavelet transformation (WT) was applied to the surface electromyographic (EMG) signal of eight shoulder muscles. Total gymnast's body energy and wavelet synergies extracted from the WT-EMG by using a non-negative matrix factorization were analyzed as a function of the body position angle of the gymnast. A cross-correlation analysis of the EMG patterns allowed determining two main groups of co-activated muscles. Two wavelet synergies representing the main spectral features (82% of the variance accounted for) discriminated the recruitment of MU. Although no task-group of MU was found among the muscles, it appeared that a higher proportion of fast MU was recruited within the muscles of the first group during the upper part of the PBGS. The last increase of total body energy before bar release was induced by the recruitment of the muscles of the second group but did not necessitate the recruitment of a higher proportion of fast MU. Such muscle coordination agreed with previous simulations of elements on high bar as well as the findings related to the recruitment of MU. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Lymer, Gaël; Vendeville, Bruno; Gaullier, Virginie; Chanier, Frank; Gaillard, Morgane
2017-04-01
The Western Tyrrhenian Basin, Mediterranean Sea, is a fascinating basin in terms of interactions between crustal tectonics, salt tectonics and sedimentation. The METYSS (Messinian Event in the Tyrrhenian from Seismic Study) project is based on 2100 km of HR seismic data acquired in 2009 and 2011 along the Eastern Sardinian margin. The main aim is to study the Messinian Salinity Crisis (MSC) in the Western Tyrrhenian Basin, but we also investigate the thinning processes of the continental crust and the timing of crustal vertical motions across this complex domain. Our first results allowed us to map the MSC seismic markers and to better constrain the timing of the rifting, which ended before the MSC across the upper and middle parts of the margin. We also evidenced that crustal activity persisted long after the end of rifting. This has been particularly observed on the upper margin, where several normal faults and a surprising compressional structure were recently active. In this study we investigate the middle margin, the Cornaglia Terrace, where the Mobile Unit (MU, mobile Messinian salt) accumulated during the MSC and acts as a décollement. Our goal is to ascertain whether or not crustal tectonics existed after the pre-MSC rift. This is a challenge where the MU is thick, because potential basement deformations could be first accommodated by the MU and therefore would not find any expression in the supra-salt layers (Upper Unit, UU and Plio-Quaternary, PQ). However our investigations clearly reveal interactions between crustal and salt tectonics along the margin. We thus evidence gravity gliding of the salt and its brittle sedimentary cover along basement slopes generated by the post-MSC tilting of some basement blocks bounded by crustal normal faults, formerly due to the rifting. Another intriguing structure also got our interest. It corresponds to a wedge-shaped of MU located in a narrow N-S half graben bounded to the west by a major, east-verging, crustal normal fault. Below the MU, the sediments thicken toward the fault. The top of the MU is sub-horizontal and the supra-salt layers are sub-horizontal. At a first glance this geometry would suggest that the pre-salt unit and the MU are syn-tectonic and that nothing happened after Messinian times. However some subtle evidence of deformations in the UU and PQ (an anticline to the west and a small west-verging normal fault in the east) imply that some crustal tectonics activity persisted after the end of the rifting. To understand why the salt unit is wedge-shaped, we considered several scenarii that we tested with physical modelling. We demonstrate that this structure is related to the post-rift activity of the major crustal normal fault, whose vertical motion has been cushioned by lateral flow of an initially tabular salt layer, which thinned upslope and inflated downslope, keeping the overlying sediments remained sub-horizontal. Such interactions between thin-skinned and thick-skinned tectonics highlight how the analysis of the salt tectonics is a powerful tool to reveal recent deep crustal tectonics in the Western Mediterranean Basin.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brima, Eid I.; Haris, Parvez I.; Jenkins, Richard O.
2006-10-01
Very little is known about arsenic (As) metabolism in healthy populations that are not exposed to high concentrations of As in their food or water. Here we present a study with healthy volunteers from three different ethnic groups, residing in Leicester, UK, which reveals statistically significant differences in the levels of total As in urine and fingernail samples. Urine (n = 63), hair (n = 36) and fingernail (n = 36) samples from Asians, Somali Black-Africans and Whites were analysed using inductively coupled plasma mass spectrometry (ICP-MS) and graphite furnace atomic absorption spectroscopy (GF-AAS). The results clearly show that themore » total concentrations of As in urine and fingernail samples of a Somali Black-African population (urine 7.2 {mu}g/g creatinine; fingernails 723.1 {mu}g/kg) are significantly (P < 0.05) different from the Asian (urine 24.5 {mu}g/g creatinine; fingernails 153.9 {mu}g/kg) and White groups (urine 20.9 {mu}g/g creatinine; fingernails 177.0 {mu}g/kg). The chemical speciation of As in the urine of the three groups was also measured using high performance liquid chromatography coupled to ICP-MS. This showed that the proportion of the total urinary As present as dimethylarsenate (DMA) was higher for the Somali Black-African group (50%) compared to the Asians (16%) and Whites (22%). However, there was no significant difference (P > 0.05) in the level of As in the hair samples from these three groups; Somali Black-Africans (116.0 {mu}g/kg), Asians (117.4 {mu}g/kg) and Whites (141.2 {mu}g/kg). Significantly different levels of total As in fingernail and urine and a higher percentage of urinary DMA in the Somali Black-Africans are suggestive of a different pattern of As metabolism in this ethnic group.« less
Constraints on cosmic strings due to black holes formed from collapsed cosmic string loops
NASA Technical Reports Server (NTRS)
Caldwell, R. R.; Gates, Evalyn
1993-01-01
The cosmological features of primordial black holes formed from collapsed cosmic string loops are studied. Observational restrictions on a population of primordial black holes are used to restrict f, the fraction of cosmic string loops which collapse to form black holes, and mu, the cosmic string mass-per-unit length. Using a realistic model of cosmic strings, we find the strongest restriction on the parameters f and mu is due to the energy density in 100MeV photons radiated by the black holes. We also find that inert black hole remnants cannot serve as the dark matter. If earlier, crude estimates of f are reliable, our results severely restrict mu, and therefore limit the viability of the cosmic string large-scale structure scenario.
NASA Technical Reports Server (NTRS)
Frederking, T. H. K.; Abbassi, P.; Afifi, F.; Khandhar, P. K.; Ono, D. Y.; Chen, W. E. W.
1987-01-01
The research and development work on Fountain Effect Pump Systems (FEP systems) has been of interest in the competition between mechanical pumps for He II and FEP units. The latter do not have moving parts. In the course of the work, the energetics have been addressed using one part of a simple four-changes-of-state cycle. One option is the FEP ideal change of state at constant chemical potential (mu). The other option is the two-state sequence mu-P with a d mu=0 state change followed by an isobar. Questions of pump behavior, of flow rate response to temperature difference at the hot end, and related questions of thermodynamic cycle completion and heat transfer have been addressed. Porous media data obtained elucidate differences between vapor-liquid phase separation (VLPS) and Zero Net Mass Transfer (ZNMF).
Pérez de Tudela, Ricardo; Aoiz, F J; Suleimanov, Yury V; Manolopoulos, David E
2012-02-16
A fundamental issue in the field of reaction dynamics is the inclusion of the quantum mechanical (QM) effects such as zero point energy (ZPE) and tunneling in molecular dynamics simulations, and in particular in the calculation of chemical reaction rates. In this work we study the chemical reaction between a muonium atom and a hydrogen molecule. The recently developed ring polymer molecular dynamics (RPMD) technique is used, and the results are compared with those of other methods. For this reaction, the thermal rate coefficients calculated with RPMD are found to be in excellent agreement with the results of an accurate QM calculation. The very minor discrepancies are within the convergence error even at very low temperatures. This exceptionally good agreement can be attributed to the dominant role of ZPE in the reaction, which is accounted for extremely well by RPMD. Tunneling only plays a minor role in the reaction.
Absolute dose calculations for Monte Carlo simulations of radiotherapy beams
NASA Astrophysics Data System (ADS)
Popescu, I. A.; Shaw, C. P.; Zavgorodni, S. F.; Beckham, W. A.
2005-07-01
Monte Carlo (MC) simulations have traditionally been used for single field relative comparisons with experimental data or commercial treatment planning systems (TPS). However, clinical treatment plans commonly involve more than one field. Since the contribution of each field must be accurately quantified, multiple field MC simulations are only possible by employing absolute dosimetry. Therefore, we have developed a rigorous calibration method that allows the incorporation of monitor units (MU) in MC simulations. This absolute dosimetry formalism can be easily implemented by any BEAMnrc/DOSXYZnrc user, and applies to any configuration of open and blocked fields, including intensity-modulated radiation therapy (IMRT) plans. Our approach involves the relationship between the dose scored in the monitor ionization chamber of a radiotherapy linear accelerator (linac), the number of initial particles incident on the target, and the field size. We found that for a 10 × 10 cm2 field of a 6 MV photon beam, 1 MU corresponds, in our model, to 8.129 × 1013 ± 1.0% electrons incident on the target and a total dose of 20.87 cGy ± 1.0% in the monitor chambers of the virtual linac. We present an extensive experimental verification of our MC results for open and intensity-modulated fields, including a dynamic 7-field IMRT plan simulated on the CT data sets of a cylindrical phantom and of a Rando anthropomorphic phantom, which were validated by measurements using ionization chambers and thermoluminescent dosimeters (TLD). Our simulation results are in excellent agreement with experiment, with percentage differences of less than 2%, in general, demonstrating the accuracy of our Monte Carlo absolute dose calculations.
Pasler, Marlies; Michel, Kilian; Marrazzo, Livia; Obenland, Michael; Pallotta, Stefania; Björnsgard, Mari; Lutterbach, Johannes
2017-09-01
The purpose of this study was to characterize a new single large-area ionization chamber, the integral quality monitor system (iRT, Germany), for online and real-time beam monitoring. Signal stability, monitor unit (MU) linearity and dose rate dependence were investigated for static and arc deliveries and compared to independent ionization chamber measurements. The dose verification capability of the transmission detector system was evaluated by comparing calculated and measured detector signals for 15 volumetric modulated arc therapy plans. The error detection sensitivity was tested by introducing MLC position and linac output errors. Deviations in dose distributions between the original and error-induced plans were compared in terms of detector signal deviation, dose-volume histogram (DVH) metrics and 2D γ-evaluation (2%/2 mm and 3%/3 mm). The detector signal is linearly dependent on linac output and shows negligible (<0.4%) dose rate dependence up to 460 MU min -1 . Signal stability is within 1% for cumulative detector output; substantial variations were observed for the segment-by-segment signal. Calculated versus measured cumulative signal deviations ranged from -0.16%-2.25%. DVH, mean 2D γ-value and detector signal evaluations showed increasing deviations with regard to the respective reference with growing MLC and dose output errors; good correlation between DVH metrics and detector signal deviation was found (e.g. PTV D mean : R 2 = 0.97). Positional MLC errors of 1 mm and errors in linac output of 2% were identified with the transmission detector system. The extensive tests performed in this investigation show that the new transmission detector provides a stable and sensitive cumulative signal output and is suitable for beam monitoring during patient treatment.
NASA Astrophysics Data System (ADS)
Pasler, Marlies; Michel, Kilian; Marrazzo, Livia; Obenland, Michael; Pallotta, Stefania; Björnsgard, Mari; Lutterbach, Johannes
2017-09-01
The purpose of this study was to characterize a new single large-area ionization chamber, the integral quality monitor system (iRT, Germany), for online and real-time beam monitoring. Signal stability, monitor unit (MU) linearity and dose rate dependence were investigated for static and arc deliveries and compared to independent ionization chamber measurements. The dose verification capability of the transmission detector system was evaluated by comparing calculated and measured detector signals for 15 volumetric modulated arc therapy plans. The error detection sensitivity was tested by introducing MLC position and linac output errors. Deviations in dose distributions between the original and error-induced plans were compared in terms of detector signal deviation, dose-volume histogram (DVH) metrics and 2D γ-evaluation (2%/2 mm and 3%/3 mm). The detector signal is linearly dependent on linac output and shows negligible (<0.4%) dose rate dependence up to 460 MU min-1. Signal stability is within 1% for cumulative detector output; substantial variations were observed for the segment-by-segment signal. Calculated versus measured cumulative signal deviations ranged from -0.16%-2.25%. DVH, mean 2D γ-value and detector signal evaluations showed increasing deviations with regard to the respective reference with growing MLC and dose output errors; good correlation between DVH metrics and detector signal deviation was found (e.g. PTV D mean: R 2 = 0.97). Positional MLC errors of 1 mm and errors in linac output of 2% were identified with the transmission detector system. The extensive tests performed in this investigation show that the new transmission detector provides a stable and sensitive cumulative signal output and is suitable for beam monitoring during patient treatment.
Tancredi, T; Temussi, P A; Picone, D; Amodeo, P; Tomatis, R; Salvadori, S; Marastoni, M; Santagada, V; Balboni, G
1991-05-01
The message domain of dermorphin (Tyr-D-Ala-Phe), a natural mu-opioid heptapeptide, has long been considered the main cause of the high mu selectivity of this peptide and of its analogues. The recent discovery, in the skin of Phyllomedusa sauvagei (i.e., the same natural source of dermorphin) and of Phyllomedusa bicolor of deltorphins, challenges this belief. Deltorphins, in fact, are three heptapeptides characterized by a message domain typical of mu-selective peptides, but endowed of an extremely high delta selectivity, the highest of all natural opioid peptides. A conformational analysis of dermorphin and deltorphins, based on nmr studies in DMSO and cryoprotective mixtures and internal energy calculations, showed that the enormous differences in receptor selectivity can be interpreted on the basis of receptor models for mu and delta opioids that recognize the same beta-turn in the N-terminal part, but discriminate for the conformation and polarity of the C-terminal part. Here we present the synthesis, biological activity, and conformational analysis in solution of three deltorphin analogues with very similar constitution, but with different net charge, different location of negative residues, or even without negative residues, which confirm these hypotheses and show that His4 can play a specific structural role.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pevtsov, A. B., E-mail: pevtsov@gvg.ioffe.ru; Grudinkin, S. A.; Poddubny, A. N.
The parameters of three-dimensional photonic crystals based on opal-VO{sub 2} composite films in the 1.3-1.6 {mu}m spectral range important for practical applications (Telecom standard) are numerically calculated. For opal pores, the range of filling factors is established (0.25-0.6) wherein the composite exhibits the properties of a three-dimensional insulator photonic crystal. On the basis of the opal-VO{sub 2} composites, three-dimensional photonic film crystals are synthesized with specified parameters that provide a maximum shift of the photonic band gap in the vicinity of the wavelength {approx}1.5 {mu}m ({approx}170 meV) at the semiconductor-metal transition in VO{sub 2}.
Emission of a pulsed purely rotational transition chemical H{sub 2}-F{sub 2} laser
DOE Office of Scientific and Technical Information (OSTI.GOV)
Molevich, N E; Pichugin, S Yu
2008-04-30
The possibility of obtaining efficient emission at purely rotational transitions of HF molecules in a pulsed chemical hydrogen fluoride laser is studied theoretically. The operation of a H{sub 2}-F{sub 2} laser with a gas pressure of 1.1 atm emitting at the v, j {yields} v, j - 1 (v = 1 - 6, j = 10 - 14) transitions is simulated taking into account resonance VR processes. The total specific laser energy release calculated over all the vibrational levels is 5.5 J L{sup -1} on purely rotational transitions at {lambda}{approx}17 {mu}m (j = 14), 3.5 J L{sup -1} at {lambda}{approx}18.5more » {mu}m (j = 13), and 2.5 J L{sup -1} at {lambda}{approx}20 {mu}m (j = 12). (lasers and amplifiers)« less
SU-F-T-177: Impacts of Gantry Angle Dependent Scanning Beam Properties for Proton Treatment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, Y; Clasie, B; Lu, H
Purpose: In pencil beam scanning (PBS), the delivered spot MU, position and size are slightly different at different gantry angles. We investigated the level of delivery uncertainty at different gantry angles through a log file analysis. Methods: 34 PBS fields covering full 360 degrees gantry angle spread were collected retrospectively from 28 patients treated at our institution. All fields were delivered at zero gantry angle and the prescribed gantry angle, and measured at isocenter with the MatriXX 2D array detector at the prescribed gantry angle. The machine log files were analyzed to extract the delivered MU per spot and themore » beam position from the strip ionization chambers in the treatment nozzle. The beam size was separately measured as a function of gantry angle and beam energy. Using this information, the dose was calculated in a water phantom at both gantry angles and compared to the measurement using the 3D γ-index at 2mm/2%. Results: The spot-by-spot difference between the beam position in the log files from the delivery at the two gantry angles has a mean of 0.3 and 0.4 mm and a standard deviation of 0.6 and 0.7 mm for × and y directions, respectively. Similarly, the spot-by-spot difference between the MU in the log files from the delivery at the two gantry angles has a mean 0.01% and a standard deviation of 0.7%. These small deviations lead to an excellent agreement in dose calculations with an average γ pass rate for all fields being approximately 99.7%. When each calculation is compared to the measurement, a high correlation in γ was also found. Conclusion: Using machine logs files, we verified that PBS beam delivery at different gantry angles are sufficiently small and the planned spot position and MU. This study brings us one step closer to simplifying our patient-specific QA.« less
Preferential motor unit loss in the SOD1G93A transgenic mouse model of amyotrophic lateral sclerosis
Hegedus, J; Putman, C T; Tyreman, N; Gordon, T
2008-01-01
The present study investigated motor unit (MU) loss in a murine model of familial amyotrophic lateral sclerosis (ALS). The fast-twitch tibialis anterior (TA) and medial gastrocnemius (MG) muscles of transgenic SOD1G93A and SOD1WT mice were studied during the presymptomatic phase of disease progression at 60 days of age. Whole muscle maximum isometric twitch and tetanic forces were 80% lower (P < 0.01) in the TA muscles of SOD1G93A compared to SOD1WT mice. Enumeration of total MU numbers within TA muscles showed a 60% reduction (P < 0.01) within SOD1G93A mice (38 ± 7) compared with SOD1WT controls (95 ± 12); this was attributed to a lower proportion of the most forceful fast-fatigable (FF) MU in SOD1G93A mice, as seen by a significant (P < 0.01) leftward shift in the cumulative frequency histogram of single MU forces. Similar patterns of MU loss and corresponding decreases in isometric twitch force were observed in the MG. Immunocytochemical analyses of the entire cross-sectional area (CSA) of serial sections of TA muscles stained with anti-neural cell adhesion molecule (NCAM) and various monoclonal antibodies for myosin heavy chain (MHC) isoforms showed respective 65% (P < 0.01) and 28% (P < 0.05) decreases in the number of innervated IIB and IID/X muscle fibres in SOD1G93A, which paralleled the 60% decrease (P < 0.01) in the force generating capacity of individual fibres. The loss of fast MUs was partially compensated by activity-dependent fast-to-slower fibre type transitions, as determined by increases (P < 0.04) in the CSA and proportion of IIA fibres (from 4% to 14%) and IID/X fibres (from 31% to 39%), and decreases (P < 0.001) in the CSA and proportion of type IIB fibres (from 65% to 44%). We conclude that preferential loss of IIB fibres is incomplete at 60 days of age, and is consistent with a selective albeit gradual loss of FF MUs that is not fully compensated by sprouting of the remaining motoneurons that innervate type IIA or IID/X muscle fibres. Our findings indicate that disease progression in fast-twitch muscles of SOD1G93A mice involves parallel processes: (1) gradual selective motor axon die-back of the FF motor units that contain large type IIB muscle fibres, and of fatigue-intermediate motor units that innervate type IID/X muscle fibres, and (2) activity-dependent conversion of motor units to those innervated by smaller motor axons innervating type IIA fatigue-resistant muscle fibres. PMID:18467368
DOT National Transportation Integrated Search
2006-06-30
This report contains the results of a study by the Federal Railroad Administration (FRA) on the safety of push-pull and multiple-unit (MU) locomotive passenger rail operations. The report addresses the following two questions: (1) Based on recent acc...
Shankar, Ravi; Jain, Archana; Singh, Atul Pratap; Kociok-Köhn, Gabriele; Molloy, Kieran C
2009-04-20
The coordination-driven self-assemblies of mixed-ligand dialkyltin derivatives, [(Et(2)Sn)(4) (O(2)P(OH)Me)(2)(O(3)PMe)(2)(OSO(2)Et)(2) x 2 H(2)O](n) 1, [(Et(2)Sn)(3)(O(3)PMe)(2)(OSO(2)Me)(2) x CHCl(3)](n) 2, and [(Me(2)Sn)(3)(O(3)PBu(t))(2)(OSO(2)Me)(2) x 2 CHCl(3)](n) 3 have been achieved by reacting the tin precursors, [R(2)Sn(OR(1))(OSO(2)R(1))](n) (R = Et, R(1) = Et (1a), Me (2a); R = Me, R(1) = Me (3a)) with an equimolar amount of methylphosphonic/t-butylphosphonic acid under mild conditions (rt, 8 h, CH(2)Cl(2)). These have been characterized by IR and multinuclear ((1)H, (13)C, (31)P, and (119)Sn) NMR spectroscopy as well as single crystal X-ray diffraction. The asymmetric unit of 1 is composed of a tetranuclear, Sn(4)(mu(2)-PO(2))(2)(mu(3)-PO(3))(2) core bearing an appended ethanesulfonate group on each terminal tin (Sn2) atom and two P(OH)...O hydrogen bonded water molecules. The ladder-like structural motif thus formed is extended into one-dimensional polymeric chains by virtue of bridging bidentate mode of the sulfonate groups. These chains are linked by O-H...O(S) hydrogen bonds involving H(2)O molecules and oxygen atoms of the sulfonate groups. The asymmetric units of 2 and 3 are composed of trinuclear tin clusters with a Sn(3)(mu(3)-PO(3))(2) core and two dangling methanesulfonate groups which are covalently bonded to the tin centers. The construction of three-dimensional self-assemblies is effected by variable bonding modes (mu(2), mu(3) in 2; mu(2) in 3) of the methanesulfonate groups. Both the structural motifs possess five- and six-coordinated tin atoms and form rectangular channels which are occupied by CHCl(3) molecules.
Cao, Wenhua; Lim, Gino; Li, Xiaoqiang; Li, Yupeng; Zhu, X. Ronald; Zhang, Xiaodong
2014-01-01
The purpose of this study is to investigate the feasibility and impact of incorporating deliverable monitor unit (MU) constraints into spot intensity optimization in intensity modulated proton therapy (IMPT) treatment planning. The current treatment planning system (TPS) for IMPT disregards deliverable MU constraints in the spot intensity optimization (SIO) routine. It performs a post-processing procedure on an optimized plan to enforce deliverable MU values that are required by the spot scanning proton delivery system. This procedure can create a significant dose distribution deviation between the optimized and post-processed deliverable plans, especially when small spot spacings are used. In this study, we introduce a two-stage linear programming (LP) approach to optimize spot intensities and constrain deliverable MU values simultaneously, i.e., a deliverable spot intensity optimization (DSIO) model. Thus, the post-processing procedure is eliminated and the associated optimized plan deterioration can be avoided. Four prostate cancer cases at our institution were selected for study and two parallel opposed beam angles were planned for all cases. A quadratic programming (QP) based model without MU constraints, i.e., a conventional spot intensity optimization (CSIO) model, was also implemented to emulate the commercial TPS. Plans optimized by both the DSIO and CSIO models were evaluated for five different settings of spot spacing from 3 mm to 7 mm. For all spot spacings, the DSIO-optimized plans yielded better uniformity for the target dose coverage and critical structure sparing than did the CSIO-optimized plans. With reduced spot spacings, more significant improvements in target dose uniformity and critical structure sparing were observed in the DSIO- than in the CSIO-optimized plans. Additionally, better sparing of the rectum and bladder was achieved when reduced spacings were used for the DSIO-optimized plans. The proposed DSIO approach ensures the deliverability of optimized IMPT plans that take into account MU constraints. This eliminates the post-processing procedure required by the TPS as well as the resultant deteriorating effect on ultimate dose distributions. This approach therefore allows IMPT plans to adopt all possible spot spacings optimally. Moreover, dosimetric benefits can be achieved using smaller spot spacings. PMID:23835656
PREDICTIONS FOR $B \\to \\tau \\bar{\\mu} + \\mu \\bar{\\tau}$
NASA Astrophysics Data System (ADS)
Boubaa, Dris; Datta, Alakabha; Duraisamy, Murugeswaran; Khalil, Shaaban
2013-12-01
The observation of B -> τ \\bar {μ } + μ \\bar {τ } at present experiments would be a clear sign of new physics. In this paper, we calculate this process in an extended Higgs sector framework where the decay is mediated by the exchange of spin zero particle with flavor changing neutral current couplings. If we identify the scalar with the newly discovered state at LHC with a mass 125 GeV then we find that, after imposing all experimental constraints, the BR(Bs -> τ \\bar {μ } + μ \\bar {τ }) can be as high as 10-6 and BR (Bd -> τ \\bar {μ } + μ \\bar {τ }) can be as high as 10-7. We also calculate this process in the minimal supersymmetric standard model and find the BR(Bs ->τ \\bar {μ } + μ \\bar {τ }) is typically of the order 10-8.
NUMERICAL CALCULATIONS ON REVERSED FIELD HEATING IN THE THETATRON
DOE Office of Scientific and Technical Information (OSTI.GOV)
Niblett, G.B.F.; Fisher, D.L.
1962-03-01
Numerical solutions of the two-fluid hydromagnetic equations designed to study the effect of trapped magnetic fields on the properties of a plasma compressed in the theta are discussed. Conditions typical of the AWRE Maggi condenser banks were selected: deuterium at an initial pressure of lOO mu contained in a tube 4 cm in diameter is compressed by a field rising to 100 kilogauss in 2.5 mu sec. Initial bias fields of between +5 and --5 kilogauss were used, and the effects of preheat and rate of compression were assessed. The calculations showed that rapid joule heating is niaintained by themore » large field gradients characteristic of reversed field discharges, and for an initial bias field of --5 kg a peak electron temperature of 1.3 kev was predicted. (auth)« less
A sEMG model with experimentally based simulation parameters.
Wheeler, Katherine A; Shimada, Hiroshima; Kumar, Dinesh K; Arjunan, Sridhar P
2010-01-01
A differential, time-invariant, surface electromyogram (sEMG) model has been implemented. While it is based on existing EMG models, the novelty of this implementation is that it assigns more accurate distributions of variables to create realistic motor unit (MU) characteristics. Variables such as muscle fibre conduction velocity, jitter (the change in the interpulse interval between subsequent action potential firings) and motor unit size have been considered to follow normal distributions about an experimentally obtained mean. In addition, motor unit firing frequencies have been considered to have non-linear and type based distributions that are in accordance with experimental results. Motor unit recruitment thresholds have been considered to be related to the MU type. The model has been used to simulate single channel differential sEMG signals from voluntary, isometric contractions of the biceps brachii muscle. The model has been experimentally verified by conducting experiments on three subjects. Comparison between simulated signals and experimental recordings shows that the Root Mean Square (RMS) increases linearly with force in both cases. The simulated signals also show similar values and rates of change of RMS to the experimental signals.
Muon Sites in Transition Metal Oxides.
NASA Astrophysics Data System (ADS)
Chan, Kwaichow Benjamin
Muon behavior in a selected series of transition -metal oxides has been investigated by the Muon Spin Rotation (muSR) technique. The materials studied are the corundum structured oxides (M_2 O_3: M = Fe, Cr, V, Ti) and the high-Tc superconducting oxides in Y-Ba-Cu-O system. The muon is first implanted into the oxide crystalline and its subsequent behavior in the presence of magnetic field is monitored through counting the positron emitted by the decayed muon. The muon is found to behave like a free muon and to become localized at low temperatures and diffusional at higher temperatures. The location of the muon is important for interpreting the muSR data. To identify muon sites, a combination of electrostatic potential and magnetic dipolar field calculation is used. Dipole -field calculation allows matching the experimental results to the calculated values if the origin of the magnetic field is dominantly dipolar as in the case of V _2O_3 and Cr _2O_3. In the potential model, in addition to the coulombic interaction, the muon is assumed to form a muon-oxygen bond in analogy to the hydroxyl bond (OH)^-. Morse potential is used to simulate the mu^+ -O^= bonding. The potential minima found are then assigned as muon sites. A set of muon sites thus found in these oxides are their implications are presented. The inadequacies of the classical model and a more realistic model for predicting muon sites are also discussed.
Regional monitoring activities, June 1958
DOE Office of Scientific and Technical Information (OSTI.GOV)
Andersen, B.V.
1958-07-17
The Klamath Falls measurements indicated old fallout materials were present on the vegetation. Cs{sup 137} on Zone B vegetation (200 East Area) averaged 4.1 {times} 10{sup -6} {mu}c/gm this month, compared to an average of 4.4 {times} 10{sup -6} {mu}c/gm last month. Other special measurements this month included calculation of reactor effluent water originated radioisotopes present in samples of Zone Z (Franklin County Irrigation District) vegetation analyzed by gamma spectroscopy. Monthly average values were below the detection limit of about 2 {times} 10{sup -6} {mu}c/gm for Zn{sup 65} and Cr{sup 57}. Maximum Zn{sup 65} concentration was 1.7 {times} 10{sup -6}more » {mu}c/gm on samples collected May 28, 1958. Crop samples of strawberries, green beans, apricots, and potatoes from the Franklin County Irrigation District were taken during June. Analytical results are not yet available. Analytical detection limits for isotopes expected in crop samples were requested at 1/500 of the public limit for human intake of the isotopes.« less
Moreno, Iván; de Vega, Manuel; León, Inmaculada
2013-08-01
The mu rhythms (8-13 Hz) and the beta rhythms (15 up to 30 Hz) of the EEG are observed in the central electrodes (C3, Cz and C4) in resting states, and become suppressed when participants perform a manual action or when they observe another's action. This has led researchers to consider that these rhythms are electrophysiological markers of the motor neuron activity in humans. This study tested whether the comprehension of action language, unlike abstract language, modulates mu and low beta rhythms (15-20 Hz) in a similar way as the observation of real actions. The log-ratios were calculated for each oscillatory band between each condition and baseline resting periods. The results indicated that both action language and action videos caused mu and beta suppression (negative log-ratios), whereas abstract language did not, confirming the hypothesis that understanding action language activates motor networks in the brain. In other words, the resonance of motor areas associated with action language is compatible with the embodiment approach to linguistic meaning. Copyright © 2013 Elsevier Inc. All rights reserved.
Developing the Precision Magnetic Field for the E989 Muon g{2 Experiment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, Matthias W.
The experimental value ofmore » $$(g\\hbox{--}2)_\\mu$$ historically has been and contemporarily remains an important probe into the Standard Model and proposed extensions. Previous measurements of $$(g\\hbox{--}2)_\\mu$$ exhibit a persistent statistical tension with calculations using the Standard Model implying that the theory may be incomplete and constraining possible extensions. The Fermilab Muon g-2 experiment, E989, endeavors to increase the precision over previous experiments by a factor of four and probe more deeply into the tension with the Standard Model. The $$(g\\hbox{--}2)_\\mu$$ experimental implementation measures two spin precession frequencies defined by the magnetic field, proton precession and muon precession. The value of $$(g\\hbox{--}2)_\\mu$$ is derived from a relationship between the two frequencies. The precision of magnetic field measurements and the overall magnetic field uniformity achieved over the muon storage volume are then two undeniably important aspects of the e xperiment in minimizing uncertainty. The current thesis details the methods employed to achieve magnetic field goals and results of the effort.« less
NASA Astrophysics Data System (ADS)
Yin, Peng; Fan, Xiaohua; Dong, Jianmin; Guo, Wenmei; Zuo, Wei
2017-05-01
The neutrino emissivities in β-stable neutron star matter from the direct Urca (DU) processes and the modified Urca (MU) processes have been investigated by adopting 26 Skyrme interactions. Several physical quantities related to the MU processes and the DU processes have been calculated and discussed. The model-dependence of the neutrino emissivities from the DU processes is found to stem mainly from the model-dependence of the effective mass, while the neutrino emissivities from the MU processes are determined by the competition between the effects of the symmetry energy and the effective mass. Besides, we have investigated the total neutrino luminosities of neutron stars, with the masses of 1.2 , 1.4 , 1.6 and 1.8M⊙, from the DU processes and the MU processes. The neutrino luminosity of a neutron star is found to be primarily determined by whether the electron DU process is allowed or not. As long as the electron DU process can occur, the total luminosity turns out to be 5 to 8 orders of magnitude larger as compared with the case that the DU process is forbidden, which indicates that the strongest model-dependence of the neutrino luminosity comes from that of the symmetry energy and the equation of state (EOS) of neutron star matter. In the case that the DU processes are allowed, the discrepancy of the calculated neutrino luminosity using various Skyrme interactions remains noticeable, which is essentially attributed to the model-dependence of the symmetry energy, the EOS of NS matter and the effective masses.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Assoud, Abdeljalil; Soheilnia, Navid; Kleinke, Holger
The title compounds were prepared from the elements in the stoichiometric ratio at 800deg. C under exclusion of air. Tl{sub 6}Si{sub 2}Te{sub 6} crystallizes in the space group P1-bar , isostructural with Tl{sub 6}Ge{sub 2}Te{sub 6}, with a=9.4235(6)A, b=9.6606(7)A, c=10.3889(7)A, {alpha}=89.158(2){sup o}, {beta}=96.544(2){sup o}, {gamma}=100.685(2){sup o}, V=923.3(1)A{sup 3} (Z=2). Its structure is composed of dimeric [Si{sub 2}Te{sub 6}]{sup 6-} units with a Si-Si single bond, while the Tl atoms are irregularly coordinated by five to six Te atoms. Numerous weakly bonding Tl-Tl contacts exist. Both title compounds are black semiconductors with small band gaps, calculated to be 0.9eV for Tl{submore » 6}Si{sub 2}Te{sub 6} and 0.5eV for Tl{sub 6}Ge{sub 2}Te{sub 6}. The Seebeck coefficients are +65{mu}VK{sup -1} in case of Tl{sub 6}Si{sub 2}Te{sub 6} and +150{mu}VK{sup -1} in case of Tl{sub 6}Ge{sub 2}Te{sub 6} at 300K, and the electrical conductivities are 5.5 and 3{omega}{sup -1}cm{sup -1}, respectively.« less
The role of complexity metrics in a multi-institutional dosimetry audit of VMAT
Agnew, Christina E; Hussein, Mohammad; Tsang, Yatman; McWilliam, Alan; Hounsell, Alan R; Clark, Catharine H
2016-01-01
Objective: To demonstrate the benefit of complexity metrics such as the modulation complexity score (MCS) and monitor units (MUs) in multi-institutional audits of volumetric-modulated arc therapy (VMAT) delivery. Methods: 39 VMAT treatment plans were analysed using MCS and MU. A virtual phantom planning exercise was planned and independently measured using the PTW Octavius® phantom and seven29® 2D array (PTW-Freiburg GmbH, Freiburg, Germany). MCS and MU were compared with the median gamma index pass rates (2%/2 and 3%/3 mm) and plan quality. The treatment planning systems (TPS) were grouped by VMAT modelling being specifically designed for the linear accelerator manufacturer's own treatment delivery system (Type 1) or independent of vendor for VMAT delivery (Type 2). Differences in plan complexity (MCS and MU) between TPS types were compared. Results: For Varian® linear accelerators (Varian® Medical Systems, Inc., Palo Alto, CA), MCS and MU were significantly correlated with gamma pass rates. Type 2 TPS created poorer quality, more complex plans with significantly higher MUs and MCS than Type 1 TPS. Plan quality was significantly correlated with MU for Type 2 plans. A statistically significant correlation was observed between MU and MCS for all plans (R = −0.84, p < 0.01). Conclusion: MU and MCS have a role in assessing plan complexity in audits along with plan quality metrics. Plan complexity metrics give some indication of plan deliverability but should be analysed with plan quality. Advances in knowledge: Complexity metrics were investigated for a national rotational audit involving 34 institutions and they showed value. The metrics found that more complex plans were created for planning systems which were independent of vendor for VMAT delivery. PMID:26511276
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dou, Xin; Kim, Yusung, E-mail: yusung-kim@uiowa.edu; Bayouth, John E.
2013-04-01
To develop an optimal field-splitting algorithm of minimal complexity and verify the algorithm using head-and-neck (H and N) and female pelvic intensity-modulated radiotherapy (IMRT) cases. An optimal field-splitting algorithm was developed in which a large intensity map (IM) was split into multiple sub-IMs (≥2). The algorithm reduced the total complexity by minimizing the monitor units (MU) delivered and segment number of each sub-IM. The algorithm was verified through comparison studies with the algorithm as used in a commercial treatment planning system. Seven IMRT, H and N, and female pelvic cancer cases (54 IMs) were analyzed by MU, segment numbers, andmore » dose distributions. The optimal field-splitting algorithm was found to reduce both total MU and the total number of segments. We found on average a 7.9 ± 11.8% and 9.6 ± 18.2% reduction in MU and segment numbers for H and N IMRT cases with an 11.9 ± 17.4% and 11.1 ± 13.7% reduction for female pelvic cases. The overall percent (absolute) reduction in the numbers of MU and segments were found to be on average −9.7 ± 14.6% (−15 ± 25 MU) and −10.3 ± 16.3% (−3 ± 5), respectively. In addition, all dose distributions from the optimal field-splitting method showed improved dose distributions. The optimal field-splitting algorithm shows considerable improvements in both total MU and total segment number. The algorithm is expected to be beneficial for the radiotherapy treatment of large-field IMRT.« less
The role of complexity metrics in a multi-institutional dosimetry audit of VMAT.
McGarry, Conor K; Agnew, Christina E; Hussein, Mohammad; Tsang, Yatman; McWilliam, Alan; Hounsell, Alan R; Clark, Catharine H
2016-01-01
To demonstrate the benefit of complexity metrics such as the modulation complexity score (MCS) and monitor units (MUs) in multi-institutional audits of volumetric-modulated arc therapy (VMAT) delivery. 39 VMAT treatment plans were analysed using MCS and MU. A virtual phantom planning exercise was planned and independently measured using the PTW Octavius(®) phantom and seven29(®) 2D array (PTW-Freiburg GmbH, Freiburg, Germany). MCS and MU were compared with the median gamma index pass rates (2%/2 and 3%/3 mm) and plan quality. The treatment planning systems (TPS) were grouped by VMAT modelling being specifically designed for the linear accelerator manufacturer's own treatment delivery system (Type 1) or independent of vendor for VMAT delivery (Type 2). Differences in plan complexity (MCS and MU) between TPS types were compared. For Varian(®) linear accelerators (Varian(®) Medical Systems, Inc., Palo Alto, CA), MCS and MU were significantly correlated with gamma pass rates. Type 2 TPS created poorer quality, more complex plans with significantly higher MUs and MCS than Type 1 TPS. Plan quality was significantly correlated with MU for Type 2 plans. A statistically significant correlation was observed between MU and MCS for all plans (R = -0.84, p < 0.01). MU and MCS have a role in assessing plan complexity in audits along with plan quality metrics. Plan complexity metrics give some indication of plan deliverability but should be analysed with plan quality. Complexity metrics were investigated for a national rotational audit involving 34 institutions and they showed value. The metrics found that more complex plans were created for planning systems which were independent of vendor for VMAT delivery.
Schmidt, Katja; Butt, Julia; Mauter, Petra; Vogel, Klaus; Erles-Kemna, Andrea; Pawlita, Michael; Nicklas, Werner
2017-01-01
Laboratory mice play a tremendous role in biomedical research in studies on immunology, infection, cancer and therapy. In the course of standardization of mice used in animal experiments, health monitoring constitutes an important instrument towards microbiological standardization. Infections with murine astroviruses (MuAstV) were only recently discovered and are, therefore, still relatively unknown in laboratory animal science. In rodent health monitoring viral infections within a population are commonly assessed in terms of specific antibodies by serological testing, as active infection and excretion of virus is often temporary and can easily be missed. So far only ongoing infections with astroviruses can be detected by PCR. The objective of this work was the development of a sensitive and specific MuAstV multiplex serological assay with a high-throughput capability to be used in routine testing of laboratory mice. Four different MuAstV proteins were recombinantly expressed and used as antigens. The best reacting antigen, the capsid spike protein VP27, was selected and tested with a panel of 400 sera of mice from units with a known MuAstV status. Assay sensitivity and specificity resulted in 98.5% and 100%, respectively, compared to RT-PCR results. Eventually this assay was used to test 5529 serum samples in total, during routine diagnostics at the German Cancer Research Center (DKFZ) in Heidelberg between 2015 and 2017. High sero-prevalence rates of up to 98% were detected in units with open cages indicating that the virus is highly infectious and circulates within these populations virtually infecting all animals regardless of the mouse strain. In addition, data collected from 312 mice purchased from commercial breeders and from 661 mice from 58 research institutes in 15 countries worldwide allowed the conclusion that MuAstV is widespread in contemporary laboratory mouse populations.
Priest, N D; Hunt, B W
1979-05-01
Values of the annual limit of intake (ALI) for plutonium-239 in man have been calculated using committed dose equivalent limits as recommended by ICRP in Publication 26. The calculations were made using a multicompartment bone model which allows for plutonium burial and recycling in the skeleton. In one skeletal compartment, the growing surfaces of cortical bone, it is assumed that plutonium deposits are retained and are not subject to resorption or recycling. In the trabecular bone compartment plutonium is taken to be resorbed with either subsequent redeposition onto bone surfaces or retention in the bone marrow. ALIs for plutonium-239 have been calculated assuming a range of rates of bone accretion (0-32 micron yr-1), different amounts of plutonium retained in the marrow (0-60%) and a 20%, 45% or 70% deposition of plutonium in the skeleton from the blood. The calculations made using this bone model suggest that 750 Bq (20 nCi) is an appropriate ALI for the inhalation of class W and class Y plutonium compounds and that 830 kBq and 5 MBq (23 muCi and 136 muCi) are the appropriate ALIs for the ingestion of soluble and insoluble forms of plutonium respectively.
Determination of output factors for small proton therapy fields.
Fontenot, Jonas D; Newhauser, Wayne D; Bloch, Charles; White, R Allen; Titt, Uwe; Starkschall, George
2007-02-01
Current protocols for the measurement of proton dose focus on measurements under reference conditions; methods for measuring dose under patient-specific conditions have not been standardized. In particular, it is unclear whether dose in patient-specific fields can be determined more reliably with or without the presence of the patient-specific range compensator. The aim of this study was to quantitatively assess the reliability of two methods for measuring dose per monitor unit (DIMU) values for small-field treatment portals: one with the range compensator and one without the range compensator. A Monte Carlo model of the Proton Therapy Center-Houston double-scattering nozzle was created, and estimates of D/MU values were obtained from 14 simulated treatments of a simple geometric patient model. Field-specific D/MU calibration measurements were simulated with a dosimeter in a water phantom with and without the range compensator. D/MU values from the simulated calibration measurements were compared with D/MU values from the corresponding treatment simulation in the patient model. To evaluate the reliability of the calibration measurements, six metrics and four figures of merit were defined to characterize accuracy, uncertainty, the standard deviations of accuracy and uncertainty, worst agreement, and maximum uncertainty. Measuring D/MU without the range compensator provided superior results for five of the six metrics and for all four figures of merit. The two techniques yielded different results primarily because of high-dose gradient regions introduced into the water phantom when the range compensator was present. Estimated uncertainties (approximately 1 mm) in the position of the dosimeter in these regions resulted in large uncertainties and high variability in D/MU values. When the range compensator was absent, these gradients were minimized and D/MU values were less sensitive to dosimeter positioning errors. We conclude that measuring D/MU without the range compensator present provides more reliable results than measuring it with the range compensator in place.
Electrical stimulation superimposed onto voluntary muscular contraction.
Paillard, Thierry; Noé, Frédéric; Passelergue, Philippe; Dupui, Philippe
2005-01-01
Electrical stimulation (ES) reverses the order of recruitment of motor units (MU) observed with voluntary muscular contraction (VOL) since under ES, large MU are recruited before small MU. The superimposition of ES onto VOL (superimposed technique: application of an electrical stimulus during a voluntary muscle action) can theoretically activate more motor units than VOL performed alone, which can engender an increase of the contraction force. Two superimposed techniques can be used: (i) the twitch interpolation technique (ITT), which consists of interjecting an electrical stimulus onto the muscle nerve; and (ii) the percutaneous superimposed electrical stimulation technique (PST), where the stimulation is applied to the muscle belly. These two superimposed techniques can be used to evaluate the ability to fully activate a muscle. They can thus be employed to distinguish the central or peripheral nature of fatigue after exhausting exercise. In general, whatever the technique employed, the superimposition of ES onto volitional exercise does not recruit more MU than VOL, except with eccentric actions. Nevertheless, the neuromuscular response associated with the use of the superimposed technique (ITT and PST) depends on the parameter of the superimposed current. The sex and the training level of the subjects can also modify the physiological impact of the superimposed technique. Although the motor control differs drastically between training with ES and VOL, the integration of the superimposed technique in training programmes with healthy subjects does not reveal significant benefits compared with programmes performed only with voluntary exercises. Nevertheless, in a therapeutic context, training programmes using ES superimposition compensate volume and muscle strength deficit with more efficiency than programmes using VOL or ES separately.
Chen, Ying-Chen; Wang, Yu-Chun; Ho, Hsiu-O; Sheu, Ming-Thau
2014-01-01
Effervescent multiple-unit floating drug delivery systems (muFDDSs) consisting of drug (lorsartan)- and effervescent (sodium bicarbonate)-containing pellets were characterized in this study. The mechanical properties (stress and strain at rupture, Young’s modulus, and toughness) of these plasticized polymeric films of acrylic (Eudragit RS, RL, and NE) and cellulosic materials (ethyl cellulose (EC), and Surelease) were examined by a dynamic mechanical analyzer. Results demonstrated that polymeric films prepared from Surelease and EC were brittle with less elongation compared to acrylic films. Eudragit NE films were very flexible in both the dry and wet states. Because plasticizer leached from polymeric films during exposure to the aqueous medium, plasticization of wet Eudragit RS and RL films with 15% triethyl citrate (TEC) or diethyl phthalate (DEP) resulted in less elongation. DEP might be the plasticizer of choice among the plasticizers examined in this study for Eudragit RL to provide muFDDSs with a short time for all pellets to float (TPF) and a longer period of floating. Eudragit RL and RS at a 1∶1 ratio plasticized with 15% DEP were optimally selected as the coating membrane for the floating system. Although the release of losartan from the pellets was still too fast as a result of losartan being freely soluble in water, muFDDSs coated with Eudragit RL and RS at a 1∶1 ratio might have potential use for the sustained release of water-insoluble or the un-ionized form of drugs from gastroretentive drug delivery systems. PMID:24967594
Lead and other trace metals in preeclampsia: A case-control study in Tehran, Iran
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vigeh, Mohsen; Yokoyama, Kazuhito; Ramezanzadeh, Fateme
2006-02-15
To assess the effects of environmental exposures to trace metals on the incidence of preeclampsia, concentrations of lead (Pb), antimony (Sb), manganese (Mn), mercury, cadmium, cobalt and zinc in umbilical cord blood (UCB) and mother whole blood (MWB) were measured in 396 postpartum women without occupational exposure to metals in Tehran, Iran, using inductively coupled plasma mass spectrometry. Mother's ages ranged from 15 to 49 (mean 27) years. Preeclampsia was diagnosed in 31 subjects (7.8%). Levels of Pb, Sb and Mn in UCB were significantly higher in preeclampsia cases [mean+/-SD of 4.30+/-2.49{mu}g/dl, 4.16+/-2.73 and 46.87+/-15.03{mu}g/l, respectively] than in controls [3.52+/-2.09{mu}g/dl,more » 3.17+/-2.68 and 40.32+/-15.19{mu}g/l, respectively] (P<0.05). The logistic regression analysis revealed that one unit increase in the common logarithms of UCB concentration of Pb, Sb or Mn led to increase in the risk of preeclampsia several-fold; unit risks (95% CI) were 12.96 (1.57-107.03), 6.11 (1.11-33.53) and 34.2 (1.81-648.04) for Pb, Sb and Mn, respectively (P<0.05). These findings suggest that environmental exposure to Pb, Sb and Mn may increase the risk of preeclampsia in women without occupational exposure; levels of metals in UCB to be sensitive indicators of female reproductive toxicity as compared with those in mother MWB. Further studies are necessary to confirm these findings, especially on Sb and Mn.« less
Improved measurement of B(D+ --> mu+nu) and the pseudoscalar decay constant fD+.
Artuso, M; Boulahouache, C; Blusk, S; Butt, J; Dorjkhaidav, O; Li, J; Menaa, N; Mountain, R; Nandakumar, R; Randrianarivony, K; Redjimi, R; Sia, R; Skwarnicki, T; Stone, S; Wang, J C; Zhang, K; Csorna, S E; Bonvicini, G; Cinabro, D; Dubrovin, M; Lincoln, A; Briere, R A; Chen, G P; Chen, J; Ferguson, T; Tatishvili, G; Vogel, H; Watkins, M E; Rosner, J L; Adam, N E; Alexander, J P; Berkelman, K; Cassel, D G; Crede, V; Duboscq, J E; Ecklund, K M; Ehrlich, R; Fields, L; Gibbons, L; Gittelman, B; Gray, R; Gray, S W; Hartill, D L; Heltsley, B K; Hertz, D; Jones, C D; Kandaswamy, J; Kreinick, D L; Kuznetsov, V E; Mahlke-Krüger, H; Meyer, T O; Onyisi, P U E; Patterson, J R; Peterson, D; Phillips, E A; Pivarski, J; Riley, D; Ryd, A; Sadoff, A J; Schwarthoff, H; Shi, X; Shepherd, M R; Stroiney, S; Sun, W M; Urner, D; Wilksen, T; Weaver, K M; Weinberger, M; Athar, S B; Avery, P; Breva-Newell, L; Patel, R; Potlia, V; Stoeck, H; Yelton, J; Rubin, P; Cawlfield, C; Eisenstein, B I; Gollin, G D; Karliner, I; Kim, D; Lowrey, N; Naik, P; Sedlack, C; Selen, M; White, E J; Williams, J; Wiss, J; Asner, D M; Edwards, K W; Besson, D; Pedlar, T K; Cronin-Hennessy, D; Gao, K Y; Gong, D T; Hietala, J; Kubota, Y; Klein, T; Lang, B W; Li, S Z; Poling, R; Scott, A W; Smith, A; Dobbs, S; Metreveli, Z; Seth, K K; Tomaradze, A; Zweber, P; Ernst, J; Severini, H; Dytman, S A; Love, W; Mehrabyan, S; Mueller, J A; Savinov, V; Li, Z; Lopez, A; Mendez, H; Ramirez, J; Huang, G S; Miller, D H; Pavlunin, V; Sanghi, B; Shipsey, I P J; Adams, G S; Anderson, M; Cummings, J P; Danko, I; Napolitano, J; He, Q; Muramatsu, H; Park, C S; Thorndike, E H; Coan, T E; Gao, Y S; Liu, F
2005-12-16
We extract a relatively precise value for the decay constant of the meson by measuring B(D+ --> mu+nu) = (4.40 +/-0.66(+0.09)(-0.12) x 10(-4) using 281 pb(-1) of data taken on phi(3770) the resonance with the CLEO-c detector. We find fD+ = (222.6 +/- 16.7(+2.8)(-3.4)) MeV, and compare with current theoretical calculations. We also set a 90% confidence upper limit on B(D+e+nu)< 2.4 x 10(-5) which constrains new physics models.
New Cross Section Data for Production of the Therapeutic Radionuclides 64Cu, 140Nd, and 192Ir
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hilgers, K.; Qaim, S.M.; Coenen, H.H.
2005-05-24
For production of the therapeutic radionuclides 64Cu, 140Nd and 192Ir new cross section data are reported, all measured using the stacked-foil technique. In the case of 64Cu, the 66Zn(d,{alpha})64Cu reaction was investigated radiochemically over the energy range of 5 to 14 MeV using highly enriched target material. From the measured excitation function the thick target yield of 64Cu was calculated as 6.6 MBq/{mu}A{center_dot}h. A comparison with other production routes is given. For production of 140Nd, both natCe(3He,xn)140Nd and 141Pr(p,2n)140Nd processes were studied. For the 141Pr(p,2n)140Nd reaction the results are consistent with the literature data in the early rising part ofmore » the excitation function; at higher energies, however, our values differ considerably. The yields of 140Nd via these reactions amount to 22 and 128 MBq/{mu}A{center_dot}h, respectively. The excitation function of the 192Os(p,n)192Ir reaction was measured from 6 to 20 MeV and the yield of 192Ir was calculated to be 0.16 MBq/{mu}A{center_dot}h.« less
Measurement of the^ 235U(n,n')^235mU Integral Cross Section in a Pulsed Reactor
NASA Astrophysics Data System (ADS)
Vieira, D. J.; Bond, E. M.; Belier, G.; Meot, V.; Becker, J. A.; Macri, R. A.; Authier, N.; Hyneck, D.; Jacquet, X.; Jansen, Y.; Legrendre, J.
2009-10-01
We will present the integral measurement of the neutron inelastic cross section of ^235U leading to the 26-minute, E*=76.5 eV isomer state. Small samples (5-20 microgm) of isotope-enriched ^235U were activated in the central cavity of the CALIBAN pulsed reactor at Valduc where a nearly pure fission neutron spectrum is produced with a typical fluence of 3x10^14 n/cm^2. After 30 minutes the samples were removed from the reactor and counted in an electrostatic-deflecting electron spectrometer that was optimized for the detection of ^235mU conversion electrons. From the decay curve analysis of the data, the 26-minute ^235mU component was extracted. Preliminary results will be given and compared to gamma-cascade calculations assuming complete K-mixing or with no K-mixing.
Test of quantum electrodynamics by muonic atoms: An experimental contribution
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tauscher, L.; Backenstoss, G.; Fransson, K.
1975-08-18
The large unexplained deviations of the experimental muonic 4-3 transitions in Ba and 5-4 transitions in Pb from calculations were found not to be existent. The absolute energies of these transitions agree, on the average, with theory to within 10 eV: The differences between experimental and calculated energies E)-E) are +2plus-or-minus13 and -2plus-or-minus12 eV for themore » $mu$$sup -$- Ba 4f$sub 5$/$sub 2$-3d$sub 3$/$sub 2$ and 4f$sub 7$/$sub 2$-3d$sub 5$/$sub 2$ transitions, respectively, and 10plus-or-minus16 and -13plus-or-minus14 eV for the $mu$$sup -$-Pb 5g$sub 7$/$sub 2$-4f$sub 5$/$sub 2$ and 5g$sub 9$/$sub 2$- 4f$sub 7$/$sub 2$ transitions, respectively.« less
Eklund, Anton; Slettengren, Martin; van der Linden, Jan
2015-04-21
In the intensive care setting, most physiologic parameters are monitored automatically. However, urine output (UO) is still monitored hourly by manually handled urinometers. In this study, we evaluated an automatic urinometer (AU) and compared it with a manual urinometer (MU). This prospective study was carried out in the intensive care unit of a cardiothoracic surgical clinic. In postoperative patients (n = 34) with indwelling urinary catheters and an expected stay of 24 hours or more, hourly UO samples were measured with an AU (Sippi, n = 220; Observe Medical, Gothenburg, Sweden) or an MU (UnoMeter™ 500, n = 188; Unomedical, Birkerød, Denmark) and thereafter validated by cylinder measurements. Malposition of the instrument at the time of reading excluded measurement. Data were analyzed with the Bland-Altman method. The performance of the MU was used as the minimum criterion of acceptance when the AU was evaluated. The loss of precision with the MU due to temporal deviation from fixed hourly measurements was recorded (n = 108). A questionnaire filled out by the ward staff (n = 28) was used to evaluate the ease of use of the AU compared with the MU. Bland-Altman analysis showed a smaller mean bias for the AU (+1.9 ml) compared with the MU (+5.3 ml) (P <0.0001). There was no statistical difference in measurement precision between the two urinometers, as defined by their limits of agreement (±15.2 ml vs. ±16.6 ml, P = 0.11). The mean temporal variation with the MU was ±7.4 minutes (±12.4%), and the limits of agreement were ±23.9 minutes (±39.8%), compared with no temporal variation with the AU (P <0.0001). The ward staff considered the AU easy to learn to use and rated it higher than the MU (P <0.0001). The AU was not inferior to the MU and was significantly better in terms of bias, temporal deviation and staff opinion, although the clinical relevance of these findings may be open to discussion.
QCD inequalities for the nucleon mass and the free energy of baryonic matter.
Cohen, Thomas D
2003-07-18
The positivity of the integrand of certain Euclidean space functional integrals for two flavor QCD with degenerate quark masses implies that the free energy per unit volume for QCD with a baryon chemical potential mu(B) (and zero isospin chemical potential) is greater than the free energy with an isospin chemical potential mu(I)=(2 mu(B)/N(c)) (and zero baryon chemical potential). The same result applies to QCD with any number of heavy flavors in addition to the two light flavors so long as the chemical potential is understood as applying to the light quark contributions to the baryon number. This relation implies a bound on the nucleon mass: there exists a particle X in QCD (presumably the pion) such that M(N)> or =(N(c) m(X)/2 I(X)) where m(X) is the mass of the particle and I(X) is its isospin.
Semiconductor bridge, SCB, ignition studies of Al/CuO thermite
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bickes, R.W. Jr.; Wackerbarth, D.E.; Mohler, J.H.
1997-04-01
The authors briefly summarize semiconductor bridge operation and review their ignition studies of Al/CuO thermite as a function of the capacitor discharge unit (CDU) firing set capacitance, charge holder material and morphology of the CuO. Ignition thresholds were obtained using a brass charge holder and a non-conducting fiber-glass-epoxy composite material, G10. At - 18 C and a charge voltage of 50V, the capacitance thresholds were 30.1 {mu}F and 2.0 {mu}F respectively. They also present new data on electrostatic discharge (ESD) and radio frequency (RF) vulnerability tests.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Xiaoping; Hammons, Casey; Richmond, Michael G.
2009-01-01
Thermolysis of the dinuclear compound [Cp*IrCl2](2) (1) with ClRe(CO)(5) (2) leads to the formation of the confacial bioctahedral compound Cp*Ir(mu-Cl)(3)Re(CO)(3) (3) in high yield. Whereas the substitution of the chloride ligands in 3 is observed on treatment with excess p-methylbenzenethiol to furnish the sulfido-bridged compound Cp*Ir(mu-SC6H4Me-4)(3)Re(CO)(3) (4), 3 undergoes fragmentation upon reaction with tertiary phosphines [PPh3 and P(OMe)(3)] to furnish the mononuclear compounds CP*IrCl2P and fac-ClRe-(CO3)P-2. Both 3 and 4 have been isolated and fully characterized in solution by IR and H-1 NMR spectroscopies, and their solid-state structures have been established by X-ray crystallography. The redox properties of 3 andmore » 4 have been explored by cyclic voltammetry, and the results are discussed relative to extended Huckel MO calculations.« less
Autier, P; Ouakrim, D A
2008-01-01
In the 2000s, most of the female population of industrialised countries had access to mammography breast cancer screening, but with variable modalities among the countries. We assessed the number of mammography units (MUs) in 31 European, North American and Asian countries where significant mammography activity has existed for over 10 years, collecting data on the number of such units and of radiologists by contacting institutions in each country likely to provide the relevant information. Around 2004, there were 32 324 MU in 31 countries, the number per million women ranging from less than 25 in Turkey, Denmark, the Netherlands, the United Kingdom, Norway, Poland and Hungary to more than 80 in Cyprus, Italy, France, the United States and Austria. In a multivariate analysis, the number of MUs was positively associated with the number of radiologists (P=0.0081), the number of women (P=0.0023) and somewhat with the country surface area (P=0.077). There is considerable variation in the density of MU across countries and the number of MUs in service are often well above what would be necessary according to local screening recommendations. High number of MUs in some countries may have undesirable consequences, such as unnecessarily high screening frequency and decreased age at which screening is started. PMID:18781176
Trombe, Jean-Christian; Galy, Jean; Enjalbert, Renée
2002-10-01
The title compound, diammonium aqua-mu-carbonato-tri-mu-oxalato-dineodymium(III) hydrate, (NH(4))(2)[Nd(2)(CO(3))(C(2)O(4))(3)(H(2)O)].H(2)O, involving the two ligands oxalate and carbonate, has been prepared hydrothermally as single crystals. The Nd atoms form a tetranuclear unit across the inversion centre at (1/2, 1/2, 1/2). Starting from this tetranuclear unit, the oxalate ligands serve to develop a three-dimensional network. The carbonate group acts as a bis-chelating ligand to two Nd atoms, and is monodentate to a third Nd atom. The oxalate groups are all bis-chelating. The two independent Nd atoms are ninefold coordinated and the coordination polyhedron of these atoms is a distorted monocapped antiprism.
An empirical model for calculation of the collimator contamination dose in therapeutic proton beams
NASA Astrophysics Data System (ADS)
Vidal, M.; De Marzi, L.; Szymanowski, H.; Guinement, L.; Nauraye, C.; Hierso, E.; Freud, N.; Ferrand, R.; François, P.; Sarrut, D.
2016-02-01
Collimators are used as lateral beam shaping devices in proton therapy with passive scattering beam lines. The dose contamination due to collimator scattering can be as high as 10% of the maximum dose and influences calculation of the output factor or monitor units (MU). To date, commercial treatment planning systems generally use a zero-thickness collimator approximation ignoring edge scattering in the aperture collimator and few analytical models have been proposed to take scattering effects into account, mainly limited to the inner collimator face component. The aim of this study was to characterize and model aperture contamination by means of a fast and accurate analytical model. The entrance face collimator scatter distribution was modeled as a 3D secondary dose source. Predicted dose contaminations were compared to measurements and Monte Carlo simulations. Measurements were performed on two different proton beam lines (a fixed horizontal beam line and a gantry beam line) with divergent apertures and for several field sizes and energies. Discrepancies between analytical algorithm dose prediction and measurements were decreased from 10% to 2% using the proposed model. Gamma-index (2%/1 mm) was respected for more than 90% of pixels. The proposed analytical algorithm increases the accuracy of analytical dose calculations with reasonable computation times.
Motor Unit Activity during Fatiguing Isometric Muscle Contraction in Hemispheric Stroke Survivors
McManus, Lara; Hu, Xiaogang; Rymer, William Z.; Suresh, Nina L.; Lowery, Madeleine M.
2017-01-01
Enhanced muscle weakness is commonly experienced following stroke and may be accompanied by increased susceptibility to fatigue. To examine the contributions of central and peripheral factors to isometric muscle fatigue in stroke survivors, this study investigates changes in motor unit (MU) mean firing rate, and action potential duration during, and directly following, a sustained submaximal fatiguing contraction at 30% maximum voluntary contraction (MVC). A series of short contractions of the first dorsal interosseous muscle were performed pre- and post-fatigue at 20% MVC, and again following a 10-min recovery period, by 12 chronic stroke survivors. Individual MU firing times were extracted using surface EMG decomposition and used to obtain the spike-triggered average MU action potential waveforms. During the sustained fatiguing contraction, the mean rate of change in firing rate across all detected MUs was greater on the affected side (-0.02 ± 0.03 Hz/s) than on the less-affected side (-0.004 ± 0.003 Hz/s, p = 0.045). The change in firing rate immediately post-fatigue was also greater on the affected side than less-affected side (-13.5 ± 20 and 0.1 ± 19%, p = 0.04). Mean MU firing rates increased following the recovery period on the less-affected side when compared to the affected side (19.3 ± 17 and 0.5 ± 20%, respectively, p = 0.03). MU action potential duration increased post-fatigue on both sides (10.3 ± 1.2 to 11.2 ± 1.3 ms on the affected side and 9.9 ± 1.7 to 11.2 ± 1.9 ms on the less-affected side, p = 0.001 and p = 0.02, respectively), and changes in action potential duration tended to be smaller in subjects with greater impairment (p = 0.04). This study presents evidence of both central and peripheral fatigue at the MU level during isometric fatiguing contraction for the first time in stroke survivors. Together, these preliminary observations indicate that the response to an isometric fatiguing contraction differs between the affected and less-affected side post-stroke, and may suggest that central mechanisms observed here as changes in firing rate are the dominant processes leading to task failure on the affected side. PMID:29225574
Low, D A; Sohn, J W; Klein, E E; Markman, J; Mutic, S; Dempsey, J F
2001-05-01
The characteristics of a commercial multileaf collimator (MLC) to deliver static and dynamic multileaf collimation (SMLC and DMLC, respectively) were investigated to determine their influence on intensity modulated radiation therapy (IMRT) treatment planning and quality assurance. The influence of MLC leaf positioning accuracy on sequentially abutted SMLC fields was measured by creating abutting fields with selected gaps and overlaps. These data were also used to measure static leaf positioning precision. The characteristics of high leaf-velocity DMLC delivery were measured with constant velocity leaf sequences starting with an open field and closing a single leaf bank. A range of 1-72 monitor units (MU) was used providing a range of leaf velocities. The field abutment measurements yielded dose errors (as a percentage of the open field max dose) of 16.7+/-0.7% mm(-1) and 12.8+/-0.7% mm(-1) for 6 MV and 18 MV photon beams, respectively. The MLC leaf positioning precision was 0.080+/-0.018 mm (single standard deviation) highlighting the excellent delivery hardware tolerances for the tested beam delivery geometry. The high leaf-velocity DMLC measurements showed delivery artifacts when the leaf sequence and selected monitor units caused the linear accelerator to move the leaves at their maximum velocity while modulating the accelerator dose rate to deliver the desired leaf and MU sequence (termed leaf-velocity limited delivery). According to the vendor, a unique feature to their linear accelerator and MLC is that the dose rate is reduced to provide the correct cm MU(-1) leaf velocity when the delivery is leaf-velocity limited. However, it was found that the system delivered roughly 1 MU per pulse when the delivery was leaf-velocity limited causing dose profiles to exhibit discrete steps rather than a smooth dose gradient. The root mean square difference between the steps and desired linear gradient was less than 3% when more than 4 MU were used. The average dose per MU was greater and less than desired for closing and opening leaf patterns, respectively, when the delivery was leaf-velocity limited. The results indicated that the dose delivery artifacts should be minor for most clinical cases, but limit the assumption of dose linearity when significantly reducing the delivered dose for dosimeter characterization studies or QA measurements.
Structural basis of agrin-LRP4-MuSK signaling
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zong, Yinong; Zhang, Bin; Gu, Shenyan
Synapses are the fundamental units of neural circuits that enable complex behaviors. The neuromuscular junction (NMJ), a synapse formed between a motoneuron and a muscle fiber, has contributed greatly to understanding of the general principles of synaptogenesis as well as of neuromuscular disorders. NMJ formation requires neural agrin, a motoneuron-derived protein, which interacts with LRP4 (low-density lipoprotein receptor-related protein 4) to activate the receptor tyrosine kinase MuSK (muscle-specific kinase). However, little is known of how signals are transduced from agrin to MuSK. Here, we present the first crystal structure of an agrin-LRP4 complex, consisting of two agrin-LRP4 heterodimers. Formation ofmore » the initial binary complex requires the z8 loop that is specifically present in neuronal, but not muscle, agrin and that promotes the synergistic formation of the tetramer through two additional interfaces. We show that the tetrameric complex is essential for neuronal agrin-induced acetylcholine receptor (AChR) clustering. Collectively, these results provide new insight into the agrin-LRP4-MuSK signaling cascade and NMJ formation and represent a novel mechanism for activation of receptor tyrosine kinases.« less
Opportunistic screening for skin cancer using a mobile unit in Brazil.
Mauad, Edmundo C; Silva, Thiago B; Latorre, Maria R D O; Vieira, René A C; Haikel, Raphael L; Vazquez, Vinicius L; Longatto-Filho, Adhemar
2011-06-06
Skin cancer is the most common malignancy in the white population worldwide. In Brazil, the National Cancer Institute (INCA) estimates that in 2010 there will be 119,780 and 5,930 new cases of non-melanoma skin cancer and melanoma, respectively. The aim of this study was to evaluate the use of a mobile unit in the diagnosis and treatment of skin cancer in several poor regions of Brazil. The diagnosis of skin cancer was accomplished through active medical screening in the prevention Mobile Unit (MU) of Barretos Cancer Hospital (BCH). The study population consisted of patients examined in the MU between 2004 and 2007, and their suspicious lesions were subjected to histopathological evaluation. Data were collected prospectively from standardized forms and analyzed. During the screening, 17,857 consultations were carried out. A total of 2012 (11.2%) cases of skin cancer were diagnosed. The predominant histological type reported was basal cell carcinoma (n = 1,642 or 81.6%), followed by squamous cell carcinoma (n = 303 or 15.1%), Bowen's disease (n = 25 or 1.2%), malignant melanoma (n = 23 or 1.1%), basosquamous cell carcinoma (n = 3 or 0.1%), miscellaneous lesions (12 or 0.6%), and metatypical carcinoma (n = 4 or 0.2%). Only 0.6% of lesions were stage III. There were no stage IV non-melanoma skin lesions, as well as no melanomas stages III and IV, found. It was observed that the MU can be a useful tool for early skin cancer diagnosis and treatment. This program probably is important, especially in developing countries with inadequate public health systems and social inequality.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haertl, Petra M., E-mail: petra.haertl@klinik.uni-regensburg.de; Pohl, Fabian; Weidner, Karin
2013-04-01
This case study presents a rare case of left-sided breast cancer in a patient with funnel chest, which is a technical challenge for radiation therapy planning. To identify the best treatment technique for this case, 3 techniques were compared: conventional tangential fields (3D conformal radiotherapy [3D-CRT]), intensity-modulated radiotherapy (IMRT), and volumetric-modulated arc therapy (VMAT). The plans were created for a SynergyS® (Elekta, Ltd, Crawley, UK) linear accelerator with a BeamModulator™ head and 6-MV photons. The planning system was Oncentra Masterplan® v3.3 SP1 (Nucletron BV, Veenendal, Netherlands). Calculations were performed with collapsed cone algorithm. Dose prescription was 50.4 Gy to themore » average of the planning target volume (PTV). PTV coverage and homogeneity was comparable for all techniques. VMAT allowed reducing dose to the ipsilateral organs at risk (OAR) and the contralateral breast compared with IMRT and 3D-CRT: The volume of the left lung receiving 20 Gy was 19.3% for VMAT, 26.1% for IMRT, and 32.4% for 3D-CRT. In the heart, a D{sub 15%} of 9.7 Gy could be achieved with VMAT compared with 14 Gy for IMRT and 46 Gy for 3D-CRT. In the contralateral breast, D{sub 15%} was 6.4 Gy for VMAT, 8.8 Gy for IMRT, and 10.2 Gy for 3D-CRT. In the contralateral lung, however, the lowest dose was achieved with 3D-CRT with D{sub 10%} of 1.7 Gy for 3D-CRT, and 6.7 Gy for both IMRT and VMAT. The lowest number of monitor units (MU) per 1.8-Gy fraction was required by 3D-CRT (192 MU) followed by VMAT (518 MU) and IMRT (727 MU). Treatment time was similar for 3D-CRT (3 min) and VMAT (4 min) but substantially increased for IMRT (13 min). VMAT is considered the best treatment option for the presented case of a patient with funnel chest. It allows reducing dose in most OAR without compromising target coverage, keeping delivery time well below 5 minutes.« less
NASA Astrophysics Data System (ADS)
Liseau, R.; White, G. J.; Larsson, B.; Sidher, S.; Olofsson, G.; Kaas, A.; Nordh, L.; Caux, E.; Lorenzetti, D.; Molinari, S.; Nisini, B.; Sibille, F.
1999-04-01
We present far infrared (45-195 mu m) spectrophotometric observations with the Iso-Lws of the active star forming rho Oph main cloud (L 1688). The [C ii] 158 mu m and [O i] 63 mu m lines were detected at each of the 33 positions observed, whereas the [O i] 145 mu m line was clearly seen toward twelve. The principal observational result is that the [C ii] 158 mu m line fluxes exhibit a clear correlation with projected distance from the dominant stellar source in the field (HD 147889). We interpret this in terms of Pdr-type emission from the surface layers of the rho Ophc. The observed [C ii] 158 mu m/[O i] 63 mu m flux ratios are larger than unity everywhere. A comparison of the [C ii] 158 mu m line emission and the Fir dust continuum fluxes yields estimates of the efficiency at which the gas in the cloud converts stellar to [C ii] 158 mu m photons (chi_ {_C II},>_{ ~ },0.5%). We first develop an empirical model, which provides us with a three dimensional view of the far and bright side of the dark rho Ophc, showing that the cloud surface towards the putative energy source is concave. This model also yields quantitative estimates of the incident flux of ultraviolet radiation (G_0 ~ , \\powten{1} - \\powten{2}) and of the degree of clumpiness/texture of the cloud surface (filling of the 80({') '} beam ~ ,0.2). Subsequently, we use theoretical models of Pdr s to derive the particle density, n(H), and the temperature structures, for T_gas and T_dust, in the surface layers of the rho Ophc. T_gas is relatively low, ~ ,60 K, but higher than T_dust ( ~ ,30 K), and densities are generally found within the interval (1-3) \\powten{4} cm(-3) . These Pdr models are moderately successful in explaining the Lws observations. They correctly predict the [O i] 63 mu m and [C ii] 158 mu m line intensities and the observed absence of any molecular line emission. The models do fail, however, to reproduce the observed small [O i] 63 mu m/[O i] 145 mu m ratios. We examine several possible explanations, but are unable to uniquely identify (or to disentangle) the cause(s) of this discrepancy. From pressure equilibrium arguments we infer that the total mass of the rho Oph main cloud (2 pc(2) ) is ~ ,2 500 Msun, which implies that the star formation efficiency to date is <_{ ~ },4%, significantly lower than previous estimates. Based on observations with ISO, an ESA project with instruments funded by ESA Member States (especially the PI countries: France, Germany, the Netherlands and the United Kingdom) and with the participation of ISAS and NASA.
Radiation hydrodynamic effects in two beryllium plates with an idealized aluminum joint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Belkov, S.A.; Mkhitarian, L.S.; Vinokurov, O.A.
A beryllium capsule formed from two hemispherical shells with a thin bond is one possible ignition target for the National Ignition Facility [J. A. Paisner {ital et al.}, Laser Focus World {bold 30}, 75 (1994)] Nonuniformities in density, opacity, and interface position at the joint between these hemishells will initiate two-dimensional (2-D) perturbations of the shock wave and material behind the shock as the shock passes through the shell perpendicular to the joint width. Rarefaction of material flow behind the shock front can cause the interface between the shell and joint material to oscillate in position. The amplitude of thesemore » oscillations may be comparable to the joint width. The evolution of these perturbations is studied by numerically simulating shock passage through flat beryllium plates containing aluminum joints. Using the MIMOSA-ND code [D. Sofronov {ital et al.}, Vopr. At. Nauki Tekh., Ser: Mat. modelirovanie fizicheskih processov {bold 2}, 3 (1990)] two different cases are calculated{emdash}a wide (10 {mu}m) and a narrow (1 {mu}m) joint of aluminum between two 150 {mu}m long semiinfinite beryllium plates. Both cases showed good agreement with an analytic representation of the oscillation behavior. For the narrow joint, a special technique allows the calculation of mixing between the joint and surrounding material caused by the Kelvin{endash}Helmholtz instability. {copyright} {ital 1999 American Institute of Physics.}« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hart, F.X.; Bates, J.B.
1998-06-01
The strain energy densities for various crystalline planes of LiCoO{sub 2} were calculated from the stiffness tensors obtained from lattice model calculations using the program GULP. In addition to Coulomb and Buckingham potentials, it was necessary to include shell models for the oxygen and cobalt ions in order to obtain acceptable agreement between the observed and calculated structural parameters and high frequency dielectric constant. The strain energy densities u due to differential thermal expansion were calculated using the theoretical stiffness tensors and estimated values for the thermal expansion coefficients of LiCoO{sub 2}. For a temperature change of 675thinsp{degree}C, these rangedmore » from 0.5 to 1.3{times}10{sup 8}thinsperg/cm{sup 3} or 5 to 13thinspJ/m{sup 2} for 1-{mu}m-thick films on alumina substrates. In particular, the energies for the (003), (101), and (104) planes were ordered as u(003){gt}u(104){gt}u(101). This suggests that the strong (101) preferred orientation of LiCoO{sub 2} films ({ge}1thinsp{mu}m thick) is due to the tendency to minimize volume strain energy that arises from differential thermal expansion between the film and the substrate. Additional properties obtained from the GULP calculations include the free energy, heat capacity, and the k=0 vibrational modes. thinsp« less
Testosterone-induced development of the rat levator ani muscle.
Tobin, C; Joubert, Y
1991-07-01
The perinatal development of the levator ani (LA) muscle in male and female rats was investigated by measuring the total number of muscle units (MU) (i.e., mononucleate cells, clustered or independent myotubes, and muscle fibers) in transverse semithin sections of the entire muscle and the MU cross-sectional area in 22-day-old fetuses (F22), 1-day-old (D1 = day of birth), 3-day-old (D3), and 6-day-old (D6) newborns. Male muscle contained 350 +/- 64 MU on F22, twice that of the female. The number of MU increased markedly in males from F22, but changed little in females; the number of MU in males was 760% that of females on D6. The MU cross-sectional area was greater in males on F22 (120.8 micron(s)2 +/- 7.5) and D1 (155.2 micron(s)2 +/- 64.8) than in females (F22: 89.2 micron(s) +/- 14.2, D1: 64.1 micron(s)2 +/- 19.7) and dropped to about 30 X micron(s)2 in both sexes on D6. Female rats given a single injection of testosterone propionate (TP) before D7 showed a significant increase in the number of fibers, but no increase in cross-sectional area. TP given after D7 had no effect on the fiber number, but increased the average cross-sectional area. The increase in fiber number induced by postnatal TP treatment was a permanent effect, still quantifiable in 15-month-old females. We conclude that the sexual dimorphism of the rat LA muscle is principally due to a dramatic increase in the MU number in male muscles during the perinatal period, rather than to involution of the fibers in female muscles as it is widely accepted. This increase seems to be, at least partly, under the control of testosterone.
Troeller, Almut; Garny, Sylvia; Pachmann, Sophia; Kantz, Steffi; Gerum, Sabine; Manapov, Farkhad; Ganswindt, Ute; Belka, Claus; Söhn, Matthias
2015-02-22
The use of high accuracy dose calculation algorithms, such as Monte Carlo (MC) and Collapsed Cone (CC) determine dose in inhomogeneous tissue more accurately than pencil beam (PB) algorithms. However, prescription protocols based on clinical experience with PB are often used for treatment plans calculated with CC. This may lead to treatment plans with changes in field size (FS) and changes in dose to organs at risk (OAR), especially for small tumor volumes in lung tissue treated with SABR. We re-evaluated 17 3D-conformal treatment plans for small intrapulmonary lesions with a prescription of 60 Gy in fractions of 7.5 Gy to the 80% isodose. All treatment plans were initially calculated in Oncentra MasterPlan® using a PB algorithm and recalculated with CC (CCre-calc). Furthermore, a CC-based plan with coverage similar to the PB plan (CCcov) and a CC plan with relaxed coverage criteria (CCclin), were created. The plans were analyzed in terms of Dmean, Dmin, Dmax and coverage for GTV, PTV and ITV. Changes in mean lung dose (MLD), V10Gy and V20Gy were evaluated for the lungs. The re-planned CC plans were compared to the original PB plans regarding changes in total monitor units (MU) and average FS. When PB plans were recalculated with CC, the average V60Gy of GTV, ITV and PTV decreased by 13.2%, 19.9% and 41.4%, respectively. Average Dmean decreased by 9% (GTV), 11.6% (ITV) and 14.2% (PTV). Dmin decreased by 18.5% (GTV), 21.3% (ITV) and 17.5% (PTV). Dmax declined by 7.5%. PTV coverage correlated with PTV volume (p < 0.001). MLD, V10Gy, and V20Gy were significantly reduced in the CC plans. Both, CCcov and CCclin had significantly increased MUs and FS compared to PB. Recalculation of PB plans for small lung lesions with CC showed a strong decline in dose and coverage in GTV, ITV and PTV, and declined dose in the lung. Thus, switching from a PB algorithm to CC, while aiming to obtain similar target coverage, can be associated with application of more MU and extension of radiotherapy fields, causing greater OAR exposition.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Knutson, Heather A.; Lewis, Nikole; Showman, Adam P.
2012-07-20
We present new, full-orbit observations of the infrared phase variations of the canonical hot Jupiter HD 189733b obtained in the 3.6 and 4.5 {mu}m bands using the Spitzer Space Telescope. When combined with previous phase curve observations at 8.0 and 24 {mu}m, these data allow us to characterize the exoplanet's emission spectrum as a function of planetary longitude and to search for local variations in its vertical thermal profile and atmospheric composition. We utilize an improved method for removing the effects of intrapixel sensitivity variations and robustly extracting phase curve signals from these data, and we calculate our best-fit parametersmore » and uncertainties using a wavelet-based Markov Chain Monte Carlo analysis that accounts for the presence of time-correlated noise in our data. We measure a phase curve amplitude of 0.1242% {+-} 0.0061% in the 3.6 {mu}m band and 0.0982% {+-} 0.0089% in the 4.5 {mu}m band, corresponding to brightness temperature contrasts of 503 {+-} 21 K and 264 {+-} 24 K, respectively. We find that the times of minimum and maximum flux occur several hours earlier than predicted for an atmosphere in radiative equilibrium, consistent with the eastward advection of gas by an equatorial super-rotating jet. The locations of the flux minima in our new data differ from our previous observations at 8 {mu}m, and we present new evidence indicating that the flux minimum observed in the 8 {mu}m is likely caused by an overshooting effect in the 8 {mu}m array. We obtain improved estimates for HD 189733b's dayside planet-star flux ratio of 0.1466% {+-} 0.0040% in the 3.6 {mu}m band and 0.1787% {+-} 0.0038% in the 4.5 {mu}m band, corresponding to brightness temperatures of 1328 {+-} 11 K and 1192 {+-} 9 K, respectively; these are the most accurate secondary eclipse depths obtained to date for an extrasolar planet. We compare our new dayside and nightside spectra for HD 189733b to the predictions of one-dimensional radiative transfer models from Burrows et al. and conclude that fits to this planet's dayside spectrum provide a reasonably accurate estimate of the amount of energy transported to the night side. Our 3.6 and 4.5 {mu}m phase curves are generally in good agreement with the predictions of general circulation models for this planet from Showman et al., although we require either excess drag or slower rotation rates in order to match the locations of the measured maxima and minima in the 4.5, 8.0, and 24 {mu}m bands. We find that HD 189733b's 4.5 {mu}m nightside flux is 3.3{sigma} smaller than predicted by these models, which assume that the chemistry is in local thermal equilibrium. We conclude that this discrepancy is best explained by vertical mixing, which should lead to an excess of CO and correspondingly enhanced 4.5 {mu}m absorption in this region. This result is consistent with our constraints on the planet's transmission spectrum, which also suggest excess absorption in the 4.5 {mu}m band at the day-night terminator.« less
Macías-Islas, Miguel A; Soria-Cedillo, Isaac F; Velazquez-Quintana, Merced; Rivera, Victor M; Baca-Muro, Verónica I; Lemus-Carmona, Edith A; Chiquete, Erwin
2013-12-01
Limited data exist on the costs of care of patients with multiple sclerosis (MS) in low- to middle-income nations. The purpose of this study was to describe the economic burden associated with care of Mexican patients with relapsing-remitting MS in a representative sample of the largest institution of the Mexican public healthcare system. We analysed individual data of 492 patients (67% women) with relapsing-remitting MS registered from January 2009 to February 2011 at the Mexican Social Security Institute. Direct costs were measured about the use of diagnostic tests, disease-modifying therapies (DMTs), symptoms control, medical consultations, relapses, intensive care and rehabilitation. Four groups were defined according to DMT alternatives: (1) interferon beta (IFNβ)-1a, 6 million units (MU); (2) IFNβ-1a, 12MU; (3) IFNβ-1b, 8MU; and (4) glatiramer acetate. All patients received DMTs for at least 1 year. The most frequently used DMT was glatiramer acetate (45.5%), followed by IFNβ-1a 12MU (22.6%), IFNβ-1b 8MU (20.7%), and IFNβ-1a 6MU (11.2%). The mean cost of a specialised medical consultation was €74.90 (US $107.00). A single relapse had a mean total cost of €2,505.97 (US $3,579.96). No differences were found in annualised relapse rates and costs of relapses according to DMT. However, a significant difference was observed in total annual costs according to treatment groups (glatiramer acetate being the most expensive), mainly due to differences in unitary costs of alternatives. From the public institutional perspective, when equipotent DMTs are used in patients with comparable characteristics, the costs of DMTs largely determine the total expenses associated with care of patients with relapsing-remitting MS in a middle-income country.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wells, Daniel M.; Chan, George H.; Ellis, Donald E.
2010-02-15
A new solid-state compound containing a heterobimetallic cluster of U and Ta, UTa{sub 2}O(S{sub 2}){sub 3}Cl{sub 6}, has been synthesized and its structure has been characterized by single-crystal X-ray diffraction methods. UTa{sub 2}O(S{sub 2}){sub 3}Cl{sub 6} was synthesized from UCl{sub 4} and Ta{sub 1.2}S{sub 2} at 883 K. The O is believed to have originated in the Ta{sub 1.2}S{sub 2} reactant. The compound crystallizes in the space group P1-bar of the triclinic system. The structure comprises a UTa{sub 2} unit bridged by mu{sub 2}-S{sub 2} and mu{sub 3}-O groups. Each Ta atom bonds to two mu{sub 2}-S{sub 2}, the mu{submore » 3}-O, and two terminal Cl atoms. Each U atom bonds to two mu{sub 2}-S{sub 2}, the mu{sub 3}-O, and four Cl atoms. The Cl atoms bridge in pairs to neighboring U atoms to form a ribbon structure. The bond distances are normal and are consistent with formal oxidation states of +IV/+V/-II/-I/-I for U/Ta/O/S/Cl, respectively. The optical absorbance spectrum displays characteristic transition peaks near the absorption edge. Density functional theory was used to assign these peaks to transitions between S{sup 1-} valence-band states and empty U 5f-6d hybrid bands. Density-of-states analysis shows overlap between Ta 5d and U bands, consistent with metal-metal interactions. - The UTa2O(S2)3Cl6 cluster with completed coordination sphere around uranium« less
SU-E-T-216: TPS QC Supporting Program by a Third-Party Evaluation Agency in Japan.
Fukata, K; Minemura, T; Kurokawa, C; Miyagishi, T; Itami, J
2012-06-01
To equalize the quality of radiation therapy in Japan by supporting quality control of radiation treatment planning system. Center for Cancer Control and Information Service in National Cancer Center supports the QA-QC of the cancer core hospitals in Japan as a third-party evaluation agency. Recently, a program for assessing the quality of treatment planning system (TPS) began as a part of our QA-QC supporting activities. In this program, a questionnaire about TPS was sent to 45 prefectural cancer core hospitals in Japan. The object of this questionnaire is to assess the proper commissioning, implement and applications of TPSs. The contents of the questionnaire are as follows; 1) calculate MUs which deliver 1000 cGy to the point of SSD = 100 cm, 10 cm depth with field sizes ranging from 5×5 to 30 × 30 cm 2 , and obtain doses at several depths for the calculated MUs, 2) calculate MUs which deliver 1000 cGy to the point of SSD = 100 cm, 10 cm depth for wedge fields whose angles are from 15 to 60 degrees, and obtain doses at several depths with the MUs, 3) calculate MU which deliver 1000 cGy to the point of STD = 100 cm, 10 cm depth with 10×10 cm 2 field size and obtain doses at several depths with the MU. In this program, 179 beam data from 44 facilities were collected. Data were compared in terms of dose per MU, output factor, wedge factor and TMR. It was found that 90% of the data agreed within 2%. The quality of the treatment planning system was investigated through the questionnaire including the information of essential beam data. We compared 179 beam data in TPSs sent from 44 facilities and 90% of the data showed good agreement. © 2012 American Association of Physicists in Medicine.
Chen, Xihua; Wu, Kechen; Snijders, Jaap G; Lin, Chensheng
2003-01-27
A series of trinuclear metal clusters MS4(M'PPh3)2(M'PPh3) (M = Mo, W; M' = Cu, Ag, Au) have been studied using the density functional theory (DFT) method. The static polarizabilities and hyperpolarizabilities of the model clusters have been calculated using the finite-field (F-F) method. The model clusters, divided into two groups, are alike in the structure of two fragments of rhombic units M-(mu-S)2-M' (M = Mo, W; M' = Cu, Ag, Au), perpendicular to each other, which are joined by sharing the bridge metal M. It is the charge transfer from one of these moieties to the other in these characteristic sulfido-transitional metal cores that is responsible for the polarizabilities and hyperpolarizabilities. This kind of electronic delocalization, different from that of the planar pi-system, is interesting and warrants further investigation. The structural effects on properties are important. In these models, considerable third-order nonlinearities are exhibited. The element substitution effect of Mo and W is weak, while that of Cu and Ag is relatively substantial. An overall order is gamma xxxx(Mo-Ag) > gamma xxxx(W-Ag) > gamma xxxx(Mo-Au) > gamma xxxx(W-Au) > gamma xxxx (Mo-Cu) > gamma xxxx(W-Cu) and gamma av(Mo-Ag) approximately gamma av(W-Ag) > gamma av(Mo-Au) approximately gamma av(W-Au) approximately gamma av (Mo-Cu) approximately gamma av(W-Cu).
Miyasaka, H; Chang, H C; Mochizuki, K; Kitagawa, S
2001-07-02
Metal-metal bonded Ru(3+)(mu-OR)(2)Ru(3+) and Ru(3.5+)(mu-OR)(2)Ru(3.5+) (R = CH(3) and CH(3)CH(2)) compounds with tetrachlorocatecholate (Cl(4)Cat) have been synthesized in the corresponding alcohol, MeOH and EtOH, from a nonbridged Ru(2+)-Ru(3+) compound, Na(3)[Ru(2)(Cl(4)Cat)(4)(THF)].3H(2)O.7THF (1). In alcohol solvents, compound 1 is continuously oxidized by oxygen to form Ru(3+)(mu-OR)(2)Ru(3+) and Ru(3.5+)(mu-OR)(2)Ru(3.5+) species. The presence of a characteristic countercation leads to selective isolation of either Ru(3+)(mu-OR)(2)Ru(3+) or Ru(3.5+)(mu-OR)(2)Ru(3.5+) as a stable adduct species. In methanol, Ph(4)PCl and dibenzo-18-crown-6-ether afford Ru(3+)(mu-OMe)(2)Ru(3+) species, [A](2)[Ru(2)(Cl(4)Cat)(4)(mu-OMe)(2)Na(2)(MeOH)(6)] ([A](+) = Ph(4)P(+) (2), [Na(dibenzo-18-crown-6)(H(2)O)(MeOH)](+) (3)), while benzo-15-crown-5-ether provides a Ru(3.5+)(mu-OMe)(2)Ru(3.5+) species, [Na(benzo-15-crown-5)(2)][Ru(2)(Cl(4)Cat)(4)(mu-OMe)(2)Na(2)(MeOH)(6)] (4). The air oxidation of 1 in a MeOH/EtOH mixed solvent (1:1 v/v) containing benzo-15-crown-5-ether provides a Ru(3.5+)(mu-OMe)(2)Ru(3.5+) species, [Na(benzo-15-crown-5)(H(2)O)][Ru(2)(Cl(4)Cat)(2)(mu-OMe)(2)Na(2)(EtOH)(2)(H(2)O)(2)(MeOH)(2)].(benzo-15-crown-5) (5). Similarly, the oxidation of 1 in ethanol with Ph(4)PCl provides a Ru(3.5+)(mu-OEt)(2)Ru(3.5+) species, (Ph(4)P)[Ru(2)(Cl(4)Cat)(4)(mu-OEt)(2)Na(2)(EtOH)(6)] (7). A selective formation of a Ru(3+)(mu-OEt)(2)Ru(3+) species, (Ph(4)P)(2)[Ru(2)(Cl(4)Cat)(4)(mu-OEt)(2)Na(2)(EtOH)(2)(H(2)O)(2)] (6), is found in the presence of pyrazine or 2,5-dimethylpyrazine. The crystal structures of these compounds, except 2 and 7, have been determined by X-ray crystallography, and all compounds have been characterized by several spectroscopic and magnetic investigations. The longer Ru-Ru bonds are found in the Ru(3+)(mu-OR)(2)Ru(3+) species (2.606(1) and 2.628(2) A for 3 and 6, respectively) compared with those of Ru(3.5+)(mu-OMe)(2)Ru(3.5+) species (2.5260(6) A and 2.514(2) A for 4 and 5, respectively). These structural features and magnetic and ESR data revealed the electronic configurations of sigma(2)pi(2)delta(2)delta(2)pi(2) and sigma(2)pi(2)delta(2)delta(2)pi(1) for Ru(3+)(mu-OR)(2)Ru(3+) and Ru(3.5+)(mu-OR)(2)Ru(3.5+), respectively, in which the former is diamagnetic and the latter is paramagnetic with S = (1)/(2) ground state. Compound 5 forms a one-dimensional chain with alternating arrangement of a Ru(3.5+)(mu-OMe)(2)Ru(3.5+) unit and a free benzo-15-crown-5-ether molecule by intermolecular hydrogen bonds (O(H(2)O).O(crown-ether) = 2.91-3.04 A). The cyclic voltammetry in DMF affords characteristic metal-origin voltammograms; two reversible and two quasi-reversible redox waves were observed. The feature of cyclic voltammograms for the Ru(3+)(mu-OR)(2)Ru(3+) species (2, 3, and 6) and the Ru(3.5+)(mu-OR)(2)Ru(3.5+) species (4 and 7) are similar to each other, indicating that both species are electrochemically stable. The isolation of the pyrazine-trans-coordinated species, [Ph(4)P][Ru(Cl(4)Cat)(2)(L)(2)] (L = pyrazine (8), 2,5-dimethylpyrazine (9)), revealed the selective isolation of 6 from pyrazine-containing solution. UV-vis spectral variation by ethanolysis for 9 demonstrated the selective conversion from the pyrazine-trans-coordinated species to the Ru(3+)(mu-OEt)(2)Ru(3+) species without an oxidation to the Ru(3.5+)(mu-OEt)(2)Ru(3.5+) species. This result suggests the presence of equilibrium between [Ru(Cl(4)Cat)(2)(L)(2)](-) and Ru(3+)(mu-OEt)(2)Ru(3+) species in the synthetic condition for 6.
Factors affecting volume calculation with single photon emission tomography (SPECT) method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, T.H.; Lee, K.H.; Chen, D.C.P.
1985-05-01
Several factors may influence the calculation of absolute volumes (VL) from SPECT images. The effect of these factors must be established to optimize the technique. The authors investigated the following on the VL calculations: % of background (BG) subtraction, reconstruction filters, sample activity, angular sampling and edge detection methods. Transaxial images of a liver-trunk phantom filled with Tc-99m from 1 to 3 ..mu..Ci/cc were obtained in 64x64 matrix with a Siemens Rota Camera and MDS computer. Different reconstruction filters including Hanning 20,32, 64 and Butterworth 20, 32 were used. Angular samplings were performed in 3 and 6 degree increments. ROI'smore » were drawn manually and with an automatic edge detection program around the image after BG subtraction. VL's were calculated by multiplying the number of pixels within the ROI by the slice thickness and the x- and y- calibrations of each pixel. One or 2 pixel per slice thickness was applied in the calculation. An inverse correlation was found between the calculated VL and the % of BG subtraction (r=0.99 for 1,2,3 ..mu..Ci/cc activity). Based on the authors' linear regression analysis, the correct liver VL was measured with about 53% BG subtraction. The reconstruction filters, slice thickness and angular sampling had only minor effects on the calculated phantom volumes. Detection of the ROI automatically by the computer was not as accurate as the manual method. The authors conclude that the % of BG subtraction appears to be the most important factor affecting the VL calculation. With good quality control and appropriate reconstruction factors, correct VL calculations can be achieved with SPECT.« less
NASA Astrophysics Data System (ADS)
Chisholm, M. H.; Cotton, F. A.; Fang, A.; Kober, E. C.
1983-09-01
The electronic structure of a Mo3(Mu sub 3-0) (Mu sub 3-OR) (Mu sub 2-OR)3(OR)6 molecule with R = H, and C3v symmetry, which serves as a model for real molecules in which R = H CH2C(CH)3 or CH(CH3)2 has been calculated by the molecular orbital method of Hall and Fenske. The calculations have been performed not only on the entire molecule, but on the Mo3(12+), Mo3O(OH)(9+) and Mo3O(OH)4(6+) fragments and the metal-metal bonding tracked through these successive stages by the ''clusters in molecules' formalism. In the full molecule, the HOMO is an e orbital that carries most of the e-type M-M bonding, while the a1-type is carried by two MO's, one of which is quite stable. The LUMO is also an e type orbital and the HOMO-LUMO gap is small (ca. 1.5 eV). It is predicted that the Mo3O(OR)10 molecules of this type will have readily accessible redox chemistry in which both oxidation and reduction steps might be slowed or irreversible judging by the character of the HOMO and LUMO of the Mo3O(OR)10 molecule. Experimental observations on Mo3O(ONe)10, Ne = CH2C(CH3)3, are in harmony with this. In addition, the absorption spectrum of Mo3O(ONe)10 has been observed and an assignment based on the calculations in proposed.
Wu, Fu-Chiao; Cheng, Horng-Long; Yen, Chen-Hsiang; Lin, Jyu-Wun; Liu, Shyh-Jiun; Chou, Wei-Yang; Tang, Fu-Ching
2010-03-07
Electron transport (ET) properties of a series of fluorinated copper-phthalocyanine (F(16)CuPc) thin films, which were deposited at different substrate temperatures (T(sub)) ranging from 30 to 150 degrees C, have been investigated by quantum mechanical calculations of the reorganization energy (lambda(reorg)), X-ray diffraction (XRD), atomic force microscopy (AFM), and microRaman spectroscopy. Density functional theory calculations were used to predict the vibrational frequencies, normal mode displacement vectors, and electron-vibrational lambda(reorg) for the F(16)CuPc molecule. The electron mobilities (mu(e)) of F(16)CuPc thin films are strongly dependent on the T(sub), and the value of mu(e) increases with increasing T(sub) from 30 to 120 degrees C, at which point it reaches its maximum value. The importance of electron-vibrational coupling and molecular microstructures for ET properties in F(16)CuPc thin films are discussed on the basis of theoretical vibrational lambda(reorg) calculations and experimental observations of resonance Raman spectra. We observed a good correlation between mu(e) and the full-width-at-half-maximum of the vibrational bands, which greatly contributed to lambda(reorg) and/or which reflects the molecular microstructural quality of the active channel. In contrast, the crystal size analysis by XRD and surface grain morphology by AFM did not reveal a clear correlation with the ET behaviours for these different F(16)CuPc thin films. Therefore, we suggest that for organic films with weak intermolecular interactions, such as F(16)CuPc, optimized microscopic molecular-scale parameters are highly important for efficient long-range charge transport in the macroscopic devices.
Measurements of fast neutrons by bubble detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Castillo, F.; Martinez, H.; Leal, B.
2013-07-03
Neutron bubble detectors have been studied using Am-Be and D-D neuron sources, which give limited energy information. The Bubble Detector Spectrometer (BDS) have six different energy thresholds ranging from 10 KeV to 10 Mev. The number of bubbles obtained in each measurement is related to the dose (standardized response R) equivalent neutrons through sensitivity (b / {mu}Sv) and also with the neutron flux (neutrons per unit area) through a relationship that provided by the manufacturer. Bubble detectors were used with six different answers (0.11 b/ {mu}Sv, 0093 b/{mu}Sv, 0.14 b/{mu}Sv, 0.17 b/{mu}Sv, 0051 b/{mu}Sv). To test the response of themore » detectors (BDS) radiate a set of six of them with different energy threshold, with a source of Am-Be, placing them at a distance of one meter from it for a few minutes. Also, exposed to dense plasma focus Fuego Nuevo II (FN-II FPD) of ICN-UNAM, apparatus which produces fusion plasma, generating neutrons by nuclear reactions of neutrons whose energy emitting is 2.45 MeV. In this case the detectors were placed at a distance of 50 cm from the pinch at 90 Degree-Sign this was done for a certain number of shots. In both cases, the standard response is reported (Dose in {mu}Sv) for each of the six detectors representing an energy range, this response is given by the expression R{sub i}= B{sub i} / S{sub i} where B{sub i} is the number of bubbles formed in each and the detector sensitivity (S{sub i}) is given for each detector in (b / {mu}Sv). Also, reported for both cases, the detected neutron flux (n cm{sup -2}), by a given ratio and the response involves both standardized R, as the average cross section sigma. The results obtained have been compared with the spectrum of Am-Be source. From these measurements it can be concluded that with a combination of bubble detectors, with different responses is possible to measure the equivalent dose in a range of 10 to 100 {mu}Sv fields mixed neutron and gamma, and pulsed generated fusion devices.« less
Gamwo, Isaac K [Murrysville, PA; Gidaspow, Dimitri [Northbrook, IL; Jung, Jonghwun [Naperville, IL
2009-11-17
A method for determining optimum catalyst particle size for a gas-solid, liquid-solid, or gas-liquid-solid fluidized bed reactor such as a slurry bubble column reactor (SBCR) for converting synthesis gas into liquid fuels considers the complete granular temperature balance based on the kinetic theory of granular flow, the effect of a volumetric mass transfer coefficient between the liquid and the gas, and the water gas shift reaction. The granular temperature of the catalyst particles representing the kinetic energy of the catalyst particles is measured and the volumetric mass transfer coefficient between the gas and liquid phases is calculated using the granular temperature. Catalyst particle size is varied from 20 .mu.m to 120 .mu.m and a maximum mass transfer coefficient corresponding to optimum liquid hydrocarbon fuel production is determined. Optimum catalyst particle size for maximum methanol production in a SBCR was determined to be in the range of 60-70 .mu.m.
Desjardins, A. E.; Plattner, R. D.; Nelson, P. E.
1997-01-01
Gibberella fujikuroi strains isolated from rice in the United States, Asia, and other geographic areas were tested for sexual fertility with members of mating population D and for production of fumonisin B(inf1) and moniliformin in culture. Of the 59 field strains tested, 32 (54%) were able to cross with tester strains of mating population D, but only a few ascospores were produced in most of these crosses. Thirty-four strains produced more than 10 (mu)g of fumonisin B(inf1) per g, but only three strains produced more than 1000 (mu)g/g. Twenty-five strains produced more than 100 (mu)g of moniliformin per g, and 15 produced more than 1,000 (mu)g/g. Seven field strains produced both fumonisin B(inf1) and moniliformin, but none of these strains produced a high level of fumonisin B(inf1) (>1,000 (mu)g/g). However, a genetic cross between a strain that produced fumonisin B(inf1) but no moniliformin and a strain that produced moniliformin but no fumonisin B(inf1) yielded progeny that produced high levels of both toxins. Strains of G. fujikuroi isolated from rice infected with bakanae disease are similar to strains of mating population D isolated from maize in their ability to produce both fumonisins and moniliformin. This finding suggests a potential for contamination of rice with both fumonisins and moniliformin. PMID:16535599
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu Ling; Graduate School of Chinese Academy of Sciences, Beijing 100039; Liu Bing
2005-11-15
Three new zinc coordination polymers [Zn{sub 2}(btc){sub 2}(H{sub 2}O){sub 2}] {sub n} .n[Zn(H{sub 2}O){sub 6}] (1), [Zn{sub 3}(btc){sub 2}(2,2'-bipy){sub 2}(H{sub 2}O){sub 3}] {sub n} .2nH{sub 2}O (2) and [Zn{sub 3}(btc){sub 2}(H{sub 2}O){sub 6}] {sub n} .nH{sub 2}O (3) (H{sub 3}btc=1,2,4-benzenetricarboxylic acid, 2,2'-bipy=2,2'-bipyridine) were obtained by the diffusion method and their crystal structures were determined by single-crystal X-ray diffraction. Compounds 1-3 have the similar tetrametallic unit [Zn{sub 4}(btc){sub 2}] SBUs and these SBUs are further connected into stair-like structure, 2-D layer and 3-D framework for 1, 2 and 3, in which the btc{sup 3-} ligands adopt {mu} {sub 3}, {mu} {submore » 4} and {mu} {sub 5} coordination modes, respectively. The title compounds show strong blue fluorescence, which may be assigned as {pi}*{sup {yields}}n transition of the ligand mixed with the ligand-to-metal change transfer (LMCT), indicating the fluorescence, indicates the title compounds may be good candidates for blue-light photoactive materials.« less
Photofission of 197Au and 209Bi at intermediate energies
NASA Astrophysics Data System (ADS)
Haba, H.; Sakamoto, K.; Igarashi, M.; Kasaoka, M.; Washiyama, K.; Matsumura, H.; Oura, Y.; Shibata, S.; Furukawa, M.; Fujiwara, I.
2003-01-01
Recoil properties and yields of radionuclides formed in the photofission of 197Au and 209Bi by bremsstrahlung of end-point energies ( E 0) from 300 to 1100 MeV have been investigated using the thick-target thick-catcher method. The kinetic energies T of the residual nuclei were deduced based on the two-step vector model and discussed by comparing with the reported results on protoninduced reactions as well as those on photospallation. The charge distribution was reproduced by a Gaussian function with the most probable charge Zp expressed by a linera function of the product mass number A and with the A-independent width FWHM CD. Based on the charge distribution parameters, the symmetric mass yield distribution with the most probable mass A p of 92 m.u. and the width FWHM MD of 39 m.u. was obtained for 197Au at E 0≥600 MeV. The A p value for 209Bi was larger by 4 m.u. than that for 197Au and the FWHM MD was smaller by 6 m.u. A comparison with the calculations using the Photon-induced Intranuclear Cascade Analysis 3 code combined with the Generalized Evaporation Model code (PICA3/GEM) was also performed.
Interpretation of mutation induction by accelerated heavy ions in bacteria
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kozubek, S.; Ryznar, L.; Horneck, G.
In this report, a quantitative interpretation of mutation induction cross sections by heavy charged particles in bacterial cells is presented. The approach is based on the calculation of the fraction of energy deposited by indirect hits in the sensitive structure. In these events the particle does not pass through the sensitive volume, but this region is hit by {delta} rays. Four track structure models, developed by Katz, Chatterjee et al, Kiefer and Straaten and Kudryashov et al., respectively, were used for the calculations. With the latter two models, very good agreement of the calculations with experimental results on mutagenesis inmore » bacteria was obtained. Depending on the linear energy transfer (LET{infinity}) of the particles, two different modes of mutagenic action of heavy ions are distinguished: {open_quotes}{delta}-ray mutagenesis,{close_quotes} which is related to those radiation qualities that preferentially kill the cells in direct hits (LET{infinity} {ge} 100 keV/{mu}m), and {open_quotes}track core mutagenesis,{close_quotes} which arises from direct hits and is observed for lighter ions or ions with high energy (LET{infinity} {le} 100 keV/{mu}m). 37 refs., 6 figs., 1 tab.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kumar, Syam; Aparna
2015-06-15
Purpose: To study the dosimetric properties of Enhanced Dynamic Wedge (EDW) using PTW Seven29 ion chamber array Methods: PTW Seven29 ion chamber array and Solid Water phantoms for different depths were used for the study. The study was carried out in Varian Clinac ix with photon energies, 6MV & 15MV. Primarily the solid water phantoms with the 2D array were scanned using a CT scanner (GE Optima 580) at different depths. These scanned images were used for EDW planning in an Eclipse treatment planning system (version 10). Planning was done for different wedge angles and for different depths for 6MVmore » & 15MV. A dose of 100 CGy was delivered in each cases. For each delivery, calculated the Monitoring Unit (MU) required. Same set-up was created before delivering the plans in Varian Clinac-ix. For each clinically relevant depth and for different wedge angles, the same MU was delivered as calculated. Different wedged dose distributions where reconstructed from the measured 2D array data using the in-house developed excel program. Results: It is observed that the shoulder like region in the profile which reduces as depth increases. For the same depth and energy, the percentage difference between planned and measured dose is lesser than 3%. For smaller wedge angles, the percentage difference is found to be greater than 3% for the largest wedge angle. Standard deviation between measured doses at shoulder region for planned and measured profiles is 0.08 and 0.02 respectively. Standard deviations between planned and measured wedge factors for different depths (2.5cm, 5cm, 10cm, and 15cm) are (0.0021, 0.0007, 0.0050, 0.0001) for 6MV and (0.0024, 0.0191, 0.0013, 0.0005) for 15MV respectively. Conclusion: The 2D Seven29 ion chamber array is a good tool for the Enhanced Dynamic Wedge (EDW) dosimetry.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yi, B; Chung, H; Mutaf, Y
Purpose: To test a novel total body irradiation (TBI) system using conformal partial arc with patient lying on the stationary couch which is biologically equivalent to a moving couch TBI. This improves the scanning field TBI, which is previously presented. Methods: The Uniform MU Modulated arc Segments TBI or UMMS-TBI scans the treatment plane with a constant machine dose rate and a constant gantry rotation speed. A dynamic MLC pattern which moves while gantry rotates has been designed so that the treatment field moves same distance at the treatment plane per each gantry angle, while maintaining same treatment field sizemore » (34cm) at the plane. Dose across the plane varies due to the geometric differences including the distance from the source to a point of interest and the different attenuation from the slanted depth which changes the effective depth. Beam intensity is modulated to correct the dose variation across the plane by assigning the number of gantry angles inversely proportional to the uncorrected dose. Results: Measured dose and calculated dose matched within 1 % for central axis and 3% for off axis for various patient scenarios. Dose from different distance does not follow the inverse square relation as it is predicted from calculation. Dose uniformity better than 5% across 180 cm at 10cm depth is achieved by moving the gantry from −55 to +55 deg. Total treatment time for 2 Gy AP/PA fields is 40–50 minutes excluding patient set up time, at the machine dose rate of 200 MU/min. Conclusion: This novel technique, yet accurate but easy to implement enables TBI treatment in a small treatment room with less program development preparation than other techniques. The VMAT function of treatment delivery is not required to modulate beams. One delivery pattern can be used for different patients by changing the monitor units.« less
Ligand versus metal protonation of an iron hydrogenase active site mimic.
Eilers, Gerriet; Schwartz, Lennart; Stein, Matthias; Zampella, Giuseppe; de Gioia, Luca; Ott, Sascha; Lomoth, Reiner
2007-01-01
The protonation behavior of the iron hydrogenase active-site mimic [Fe2(mu-adt)(CO)4(PMe3)2] (1; adt=N-benzyl-azadithiolate) has been investigated by spectroscopic, electrochemical, and computational methods. The combination of an adt bridge and electron-donating phosphine ligands allows protonation of either the adt nitrogen to give [Fe2(mu-Hadt)(CO)4(PMe3)2]+ ([1 H]+), the Fe-Fe bond to give [Fe2(mu-adt)(mu-H)(CO)4(PMe3)2]+ ([1 Hy]+), or both sites simultaneously to give [Fe2(mu-Hadt)(mu-H)(CO)4(PMe3)2]2+ ([1 HHy]2 +). Complex 1 and its protonation products have been characterized in acetonitrile solution by IR, (1)H, and (31)P NMR spectroscopy. The solution structures of all protonation states feature a basal/basal orientation of the phosphine ligands, which contrasts with the basal/apical structure of 1 in the solid state. Density functional calculations have been performed on all protonation states and a comparison between calculated and experimental spectra confirms the structural assignments. The ligand protonated complex [1 H]+ (pKa=12) is the initial, metastable protonation product while the hydride [1 Hy]+ (pKa=15) is the thermodynamically stable singly protonated form. Tautomerization of cation [1 H]+ to [1 Hy]+ does not occur spontaneously. However, it can be catalyzed by HCl (k=2.2 m(-1) s(-1)), which results in the selective formation of cation [1 Hy]+. The protonations of the two basic sites have strong mutual effects on their basicities such that the hydride (pK(a)=8) and the ammonium proton (pK(a)=5) of the doubly protonated cationic complex [1 HHy]2+ are considerably more acidic than in the singly protonated analogues. The formation of dication [1 HHy]2+ from cation [1 H]+ is exceptionally slow with perchloric or trifluoromethanesulfonic acid (k=0.15 m(-1) s(-1)), while the dication is formed substantially faster (k>10(2) m(-1) s(-1)) with hydrobromic acid. Electrochemically, 1 undergoes irreversible reduction at -2.2 V versus ferrocene, and this potential shifts to -1.6, -1.1, and -1.0 V for the cationic complexes [1 H]+, [1 Hy]+, and [1 HHy]2+, respectively, upon protonation. The doubly protonated form [1 HHy]2+ is reduced at less negative potential than all previously reported hydrogenase models, although catalytic proton reduction at this potential is characterized by slow turnover.
CMB and the elementary particles structure deduced from QFT of non-dot model
NASA Astrophysics Data System (ADS)
Chen, Shao-Guang
In my paper ‘Planck Constant Deduced from Metrical Results of Doppler Effect of Moving Particle —Uncertainty Principle Caused by Collision of a Particle with CMB Photons and Virtual Photons (H05-0036-10)’ the absolute velocity is decided by CMB which as a mark of the vacuum. CMB come from the thermal radiation of stars via gravitational redshift about 10 (13) year (E14- 0032-08). In my paper ‘Quanta turn-advance ism, China Science && Technology Overview 131 192-210 (2011)’, QFT four-dimensional uncertainty principle and momentum-energy conservation law had been generalized as a five-dimensional equations: de Broglie wavelength as a position vector \\underline{q}= (i c t, r, s), momentum \\underline{P} = (i E / c, P, U c), \\underline{q} = i h / \\underline{P}, \\underline{q} \\underline{q} = 0, \\underline{P} \\underline{P} = 0, Sigma∑ \\underline{P} = \\underline{P} (0) . The five-dimensional time-space-spin had been quantized as a non-dot model basic cell, the lowest energy state vertical polarized left spin 1/2 neutrino and right spin 1/2 antineutrino are just the left, right advance unit quanta _{0}nuυ, nuυ _{0} and left, right back unit quanta (0) nuυ, nuυ (0) , it again compose into spin 1 unit advance photons _{0}nuυnuυ _{0} and back (0) nuυnuυ (0) , spin 0 unit rest mass nuυ _{0}nuυ (0) and anti-mass _{0}nuυ (0) nuυ, spin 0 unit positive charge _{0}nuυnuυ (0) and negative charge nuυ _{0} (0) nuυ. It accord to the high energy physics experimental results of the transformation among the photons, masses quanta and charges quanta. The physical vacuum is the even collocation of non-combinational nuυ _{0} or _{0}nuυ. QFT is no longer with divergence difficulty by the non-dot model. It is mathematically easy that from five-dimensional equations deduce out the Dirac, Klein-Gordan, Maxwell equations and Lorentz force formula, but appear some new results. The interactions between _{0}nuυ, nuυ _{0}, (0) nuυ, nuυ (0) , i.e., force f = ± ( h c / 2 r (3) ) r cos thetaθ for r not equal to 0 and f = 0 for r = 0, f as the magnetic force makes the photons, rest mass and charge quanta automatically come into being and stabilize. CMB photon can be produced from many spin 1 unit photons by its statistical attraction. In the quantized inconsecutive time-space-spin using momentum and turn-quantity as the coordinates drawing the momentum-turn graphics are some points with certain distance. The rest mass m _{0} is the lowest energy state advance-back neutrinos pair nuυ _{0}nuυ (0) , when j direction have 2n nuυ_{0} the i , k directions must have (2n-1), (2n+1) nuυ_{0} for i, j, k three directions all matching into pair to eliminate the external interaction of electric quantity q(0) in nuυ_{0}. The spatial rest mass is quanta (n) m _{0} = (2n - 1) 2n (2n +1) m (0) = 6, 60, 210, 504, 990, 1716 m (0) , m (0) is the rest mass of nuυ_{0} (also anti-mass (n) \\underline{m}_{0} and \\underline{m}(0) ). According to the uncertainty principle n large rest mass layer is more little and at the inside layer of particle. The spatial unit charge quanta e or \\underline{e} is constituted by nine one-dimensional unit charge quanta nuυ_{0}(0) nuυ or _{0}nuυnuυ (0) because of the vertical polarization at each spatial direction there is only three states: the left, the right and the middle of left-right balance. Via photons, rest mass and charge quanta all elementary particles come from _{0}nuυ, nuυ_{0}, (0) nuυ, nuυ (0) . The particle’s momentum is constituted by the photons _{0}nuυnuυ _{0} or (0) nuυnuυ (0) and a few nuυ _{0} or _{0}nuυ. The particle’s charge is constituted by one e or \\underline{e} and one nuυ _{0} or _{0}nuυ. The particle’s rest mass is constituted by one or several (n) m _{0} or (n) \\underline{m} _{0}. According to the uncertainty principle n large rest mass layer is more little and at the inside layer of particle. The left spin 1/2 nu υ _{mu}: 1 _{0}nuυ + 1 (n) \\underline{m} _{0}, right spin 1/2 nuυ _{mu}: 1 nuυ _{0} +1 (n) m _{0}. The e (+) :1 nuυ _{0 } +1 \\underline{e} (9 _{0} nuυnuυ (0) ) + 1 (5) \\underline{m} _{0} + 6 (2) \\underline{m} _{0} , with one positive electron charge q (+) (9.5 _{0}nuυnuυ (0) ) and rest anti- mass (990+6*60)= 1350 \\underline{m} _{nu}. The e (-) : 1 _{0}nuυ +1 e (9 nuυ_{0} (0) nuυ) + (5) m _{0} + 6 (2) m_{0} with one electron charge q (-) (9.5 nuυ}_{0}(0) nuυ) and rest mass (990+6*60)=1350 m_{nu}. The electronic mass m_{e} = 1+18+1350 = 1369 m _{nu} , V = m_{nu} c /m = 219 km/s which accord to the solar system speed of astronomy observation and as a reason of the electronic stabilization. The neutral electron nuυ_{mu} (0) ( (0) nuυ_{mu}): 1 nuυ _{0} ( _{0} nuυ) + 3 (1) m _{0} (18 m _{nu}) + 6 (2) m _{0} + (5) m _{0} =1369 m_{nu} (\\underline{m} _{nu}). They are as the nu υ _{mu} and \\underline{nu υ}_{mu} with electronic mass and only in the weak interaction which maybe had been observed in the neutrinos but in the dark. With (0) nuυ_{mu} and nuυ_{mu} (0) as new unit compose the elementary particles. The (n) m ((n) \\underline{m}) = (2n-1) 2n (2n+1) m_{e} (\\underline{m}_{e}). The piπ (0) meson: (1) m + (2) m (66 m _{e}) is the flat shape, for the spatial symmetry two superposition to ({2) -1} m (2) (132 m _{e}), again with ({2) -1} \\underline{m} (2) (132 \\underline{m} _{e}) compose into piπ (0) meson with rest mass 264 m _{e}. The mu (-) and mu (+) : (3) m ( (3) \\underline{m}) outside layer i, j, k each direction one nuυ _{mu} (0) ( (0) nuυ_{mu}) to be replaced by one _{0} nuυ and e (nuυ _{0} and \\underline{e}), its rest mass is ( 210 - 3 + (19/1369)) m _{e} (\\underline{m}_{e}) = 207.02 m_{e} (\\underline{m}_{e}). The piπ (-) and piπ (+) : muμ (-) + ({2) -1} m = piπ (-) with 273.02 m _{e}, muμ (+) + ({2) -1} m _{e} =piπ (+) with 273.02 m _{e} (n) m _{e} = 6, 60, 210, 504, 990, 1716 m _{e} (\\underline{m} _{e}) still come into existent, m _{e} is the rest mass of electron. The p (+) and p (-) : (5) m + (4) m + ({3) }m + ({2) -1}m(2) = 1836 m_{e}, its outside layer is (2) m_{0} ({2) }(120 m _{nu}), \\underline{e} (18 m _{nu}) and one _{0} nuυ with 139 m_{nu} = (139/1369) m _{e} = 0.1 m_{e}, it is just the proton p (+) with 1836.10 m_{e}. The antiproton p (-) : with 1836.10 \\underline{m}_{e}, one e and one nuυ_{0}. The n and \\underline{n} : In p (+) outside layer the _{0} nuυ (1 m _{nu} ), e (18 m_{nu}) and (2) m_{0} (2) (120 m _{nu}) are replaced by two nuυ_{mu}(0) and one sub-nuυ_{mu} (0) which (5) m_{0} exchange into (4) m_{0}) become 1838.64 m_{e}), again absorb one vacuum nuυ_{0} become the neutron n. The anti-neutron n has 1838.64 \\underline{m}_{e} and one _{0}nuυ. The essence of strangeness is that: one left turn anti-mass ({2) -1} \\underline{m}(2) (132 m_{e}) interfuse in great right mass particle then the strange number S = -1, such as K (0) , LambdaΛ(0) , Sigma∑(0,+,-) , two (2-1) \\underline{m}(2) then S = -2 such as XiΞ(0,-) ; one right turn mass ({2) -1}m(2) (132 m_{e}) interfuse in great left turn anti-mass particle then the strange number S = + 1 such as \\underline{K}(0) , \\underline{LambdaΛ} (0) , \\underline{Sigma∑}(0,+,-) , two ({2) -1}m(2) then S = + 2 such as \\underline{XiΞ}(0,-) . All strange particles as positive -negative pair to be produced from the particle’s momentum in accelerator, on the fountainhead, all come from the neutral microwave photons. Only from the collective structure of the photons, rest mass and charge quanta we can understand the strange particles producing process and the strange number invariable law. From the structure of elementary particles it may be obtained that the gravitational constant is likely dependent on the absolute velocity of galaxy.
Gilmore, Kevin J; Allen, Matti D; Doherty, Timothy J; Kimpinski, Kurt; Rice, Charles L
2017-09-01
We assessed motor unit (MU) properties and neuromuscular stability in the tibialis anterior (TA) of chronic inflammatory demyelinating polyneuropathy (CIDP) patients using decomposition-based quantitative electromyography. Dorsiflexion strength was assessed, and surface and concentric needle electromyography were sampled from the TA. Estimates of MU numbers were derived using decomposition-based quantitative electromyography and spike-triggered averaging. Neuromuscular transmission stability was assessed from concentric needle-detected MU potentials. CIDP patients had 43% lower compound muscle action potential amplitude than controls, and despite near-maximum voluntary activation, were 37% weaker. CIDP had 27% fewer functioning MUs in the TA, and had 90% and 44% higher jiggle and jitter values, respectively compared with controls. CIDP had lower strength and compound muscle action potential values, moderately fewer numbers of MUs, and significant neuromuscular instability compared with controls. Thus, in addition to muscle atrophy, voluntary weakness is also due to limitations of peripheral neural transmission consistent with demyelination. Muscle Nerve 56: 413-420, 2017. © 2016 Wiley Periodicals, Inc.
Systemic penicillin as an experimental model of epilepsy.
Chen, R C; Huang, Y H; How, S W
1986-06-01
Systemic use of high-dose penicillin was studied in rats and cats to establish an experimental model of epilepsy. In rats, intraperitoneal injection of 2.5 to 5.0 million units/kg (MU/kg) penicillin was effective to induce spikes in 45.7 +/- 31.0 min (means +/- SD) and seizure in 71.5 +/- 38.4 min. In cats, intravenous administration of penicillin at 0.5 to 1.0 MU/kg induced spikes in 10.4 +/- 7.8 min and seizure in 32.2 +/- 19.8 min. Intraperitoneal use of penicillin at 1.0 to 2.0 MU/kg caused spikes in 24.0 +/- 18.4 min and seizure in 71.2 +/- 38.3 min. Pretreatment with intravenous isoniazid at 16.3 +/- 10.3 mg/kg significantly delayed the appearance of intravenous penicillin-induced spikes to 63.1 +/- 49.8 min or prevented the appearance of spikes and abolished the occurrence of seizures. Acupuncture at various points increased the penicillin-induced spikes and seizures.
The permanent electric dipole moment of CaOH
NASA Technical Reports Server (NTRS)
Bauschlicher, Charles W., Jr.; Langhoff, Stephen R.; Steimle, Timothy; Shirley, Jeffrey E.
1990-01-01
The X 2 Sigma(+), A 2Pi, and B 2Sigma(+) states of CaOH are characterized theoretically and experimentally, with a focus on the value of the permanent electric dipole moment (mu). Calculations based on SCF and SDCI studies of CaOH (Bauschlicher et al., 1984 and 1986) give mu values of 0.98, 0.49, and 0.11 D for the X, A, and B states, respectively, in good agreement with experiments in which the pure rotational spectra of these states were not detected. Modified Rittner (1951) and ligand-field models of these states are explored in detail, and the applicability of these results to observational searches for CaOH in circumstellar envelopes is indicated.
Results of dosimetric measurements in space missions
NASA Astrophysics Data System (ADS)
Reitz, G.; Beaujean, R.; Heilmann, C.; Kopp, J.; Leicher, M.; Strauch, K.
Detector packages consisting of plastic nuclear track detectors, nuclear emulsions, and thermoluminescence detectors were exposed at different locations inside the space laboratory Spacelab and at the astronauts' body and in different sections of the MIR space station. Total dose, particle fluence rate and linear energy transfer (LET) spectra of heavy ions, number of nuclear disintegrations and fast neutron fluence rates were determined of each exposure. The dose equivalent received by the Payload specialists (PSs) were calculated from the measurements, they range from 190 muSv d^-1 to 770 muSv d^-1. Finally, a preliminary investigation of results from a particle telescope of two silicon detectors, first used in the last BIORACK mission on STS 76, is reported.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adrada, A; Tello, Z; Medina, L
Purpose: The purpose of this work was to develop and validate an open source independent MU dose calculation software for 3D conformal radiotherapy with multileaf high and low resolution according to the report of AAPM TG 11 Methods: Treatment plans were done using Iplan v4.5 BrainLAB TPS. A 6MV photon beam produced by Primus and Novalis linear accelerators equipped with an Optifocus MLC and HDMLC, respectively. TPS dose calculation algorithms were pencil beam and Monte Carlo. 1082 treatments plans were selected for the study. The algorithm was written in free and open source CodeBlocks C++ platform. Treatment plans were importedmore » by the software using RTP format. Equivalent size field is obtained from the positions of the leaves; the effective depth of calculation can be introduced by TPS's dosimetry report or automatically calculated starting from SSD. The inverse square law is calculated by the 3D coordinates of the isocenter and normalization point of the treatment plan. The dosimetric parameters TPR, Sc, Sp and WF are linearly interpolated. Results: 1082 plans of both machines were analyzed. The average uncertainty between the TPS and the independent calculation was −0.43% ± 2.42% [−7.90%, 7.50%]. Specifically for the Primus the variation obtained was −0.85% ± 2.53% and for the Novalis 0.00% ± 2.23%. Data show that 94.8% of the cases the uncertainty was less than or equal to 5%, while 98.9% is less than or equal to 6%. Conclusion: The developed software is appropriate for use in calculation of UM. This software can be obtained upon request.« less
Dobrzynska, Z; Celichowski, J
2016-02-01
The early phase of development of muscles stops following the disappearance of embryonic and neonatal myosin and the elimination of polyneuronal innervation of muscle fibres with the formation of motor units (MUs), but later the muscle mass still considerably increases. It is unknown whether the three types are visible among newly formed MUs soon after the early postnatal period and whether their proportion is similar to that in adult muscle. Moreover, the processes responsible for MU-force regulation by changes in motoneuronal firing rate as well as properties of motor unit action potentials (MUAPs) during maturation are unknown. Three groups of Wistar rats were investigated - 1 month old, 2 months old and the adult, 9 months old. The basic contractile properties and action potentials of MUs in the medial gastrocnemius (MG) muscle were analysed. The three types of MUs were distinguishable in all age groups, but higher proportion of slow MUs was noticed in young rats (29%, 18% and 11% in 1, 2 and 9 months rats, respectively). The fatigue index for fast fatigable MUs in 1 month old rats was about 2 times higher than in 9 months old rats. The twitch time parameters of fast MUs were shortened during the maturation; for these units, the force-frequency curves in young rats were shifted towards lower frequencies, which suggested that fast motoneurons of young animals generate lower firing rates. Higher twitch-to-tetanus ratios noted for the three MU types in young rats suggested the smaller role of rate coding in force regulation processes, and the higher role of MU recruitment in young rats. No significant differences in MUAP parameters between two groups of young and adult animals were observed. Concluding, the maturation process evokes deeper changes in fast MUs than in slow ones.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-31
... values for two monitors in Missoula County were 11.1, 11.4 and 11.8 [mu]g/m\\3\\. Computed from AQS... domain * * *''). \\16\\ The 400 mile distance to the nonattainment area is calculated from St. Cloud, and...
NASA Technical Reports Server (NTRS)
Larson, David J.; Casagrande, Luis G.; DiMarzio, Don; Alexander, J. Iwan D.; Carlson, Fred; Lee, Taipo; Dudley, Michael; Raghathamachar, Balaji
1998-01-01
The Orbital Processing of High-Quality Doped and Alloyed CdTe Compound Semiconductors program was initiated to investigate, quantitatively, the influences of gravitationally dependent phenomena on the growth and quality of bulk compound semiconductors. The objective was to improve crystal quality (both structural and compositional) and to better understand and control the variables within the crystal growth production process. The empirical effort entailed the development of a terrestrial (one-g) experiment baseline for quantitative comparison with microgravity (mu-g) results. This effort was supported by the development of high-fidelity process models of heat transfer, fluid flow and solute redistribution, and thermo-mechanical stress occurring in the furnace, safety cartridge, ampoule, and crystal throughout the melting, seeding, crystal growth, and post-solidification processing. In addition, the sensitivity of the orbital experiments was analyzed with respect to the residual microgravity (mu-g) environment, both steady state and g-jitter. CdZnTe crystals were grown in one-g and in mu-g. Crystals processed terrestrially were grown at the NASA Ground Control Experiments Laboratory (GCEL) and at Grumman Aerospace Corporation (now Northrop Grumman Corporation). Two mu-g crystals were grown in the Crystal Growth Furnace (CGF) during the First United States Microgravity Laboratory Mission (USML-1), STS-50, June 24 - July 9, 1992.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yeh, Hsu-Chi; Phalen, R.F.; Chang, I.
1995-12-01
The National Council on Radiation Protection and Measurements (NCRP) in the United States and the International Commission on Radiological Protection (ICRP) have been independently reviewing and revising respiratory tract dosimetry models for inhaled radioactive aerosols. The newly proposed NCRP respiratory tract dosimetry model represents a significant change in philosophy from the old ICRP Task Group model. The proposed NCRP model describes respiratory tract deposition, clearance, and dosimetry for radioactive substances inhaled by workers and the general public and is expected to be published soon. In support of the NCRP proposed model, ITRI staff members have been developing computer software. Althoughmore » this software is still incomplete, the deposition portion has been completed and can be used to calculate inhaled particle deposition within the respiratory tract for particle sizes as small as radon and radon progeny ({approximately} 1 nm) to particles larger than 100 {mu}m. Recently, ICRP published their new dosimetric model for the respiratory tract, ICRP66. Based on ICRP66, the National Radiological Protection Board of the UK developed PC-based software, LUDEP, for calculating particle deposition and internal doses. The purpose of this report is to compare the calculated respiratory tract deposition of particles using the NCRP/ITRI model and the ICRP66 model, under the same particle size distribution and breathing conditions. In summary, the general trends of the deposition curves for the two models were similar.« less
Bruce, Michael I; Costuas, Karine; Davin, Thomas; Halet, Jean-François; Kramarczuk, Kathy A; Low, Paul J; Nicholson, Brian K; Perkins, Gary J; Roberts, Rachel L; Skelton, Brian W; Smith, Mark E; White, Allan H
2007-12-14
The sequential conversion of [OsBr(cod)Cp*] (9) to [OsBr(dppe)Cp*] (10), [Os([=C=CH2)(dppe)Cp*]PF6 ([11]PF6), [Os(C triple bond CH)(dppe)Cp*] (12), [{Os(dppe)Cp*}2{mu-(=C=CH-CH=C=)}][PF6]2 ([13](PF6)2) and finally [{Os(dppe)Cp*}(2)(mu-C triple bond CC triple bond C)] (14) has been used to make the third member of the triad [{M(dppe)Cp*}2(mu-C triple bond CC triple bond C)] (M = Fe, Ru, Os). The molecular structures of []PF6, 12 and 14, together with those of the related osmium complexes [Os(NCMe)(dppe)Cp*]PF6 ([15]PF6) and [Os(C triple bond CPh)(dppe)Cp*] (16), have been determined by single-crystal X-ray diffraction studies. Comparison of the redox properties of 14 with those of its iron and ruthenium congeners shows that the first oxidation potential E1 varies as: Fe approximately Os < Ru. Whereas the Fe complex has been shown to undergo three sequential 1-electron oxidation processes within conventional electrochemical solvent windows, the Ru and Os compounds undergo no fewer than four sequential oxidation events giving rise to a five-membered series of redox related complexes [{M(dppe)Cp*}2(mu-C4)]n+ (n = 0, 1, 2, 3 and 4), the osmium derivatives being obtained at considerably lower potentials than the ruthenium analogues. These results are complimented by DFT and DT DFT calculations.
Distributed parallel messaging for multiprocessor systems
Chen, Dong; Heidelberger, Philip; Salapura, Valentina; Senger, Robert M; Steinmacher-Burrow, Burhard; Sugawara, Yutaka
2013-06-04
A method and apparatus for distributed parallel messaging in a parallel computing system. The apparatus includes, at each node of a multiprocessor network, multiple injection messaging engine units and reception messaging engine units, each implementing a DMA engine and each supporting both multiple packet injection into and multiple reception from a network, in parallel. The reception side of the messaging unit (MU) includes a switch interface enabling writing of data of a packet received from the network to the memory system. The transmission side of the messaging unit, includes switch interface for reading from the memory system when injecting packets into the network.
Miller, Jonathan D; Sterczala, Adam J; Trevino, Michael A; Herda, Trent J
2018-05-01
We examined differences between normal weight (NW) and overweight (OW) children aged 8-10 yr in strength, muscle composition, and motor unit (MU) behavior of the first dorsal interosseous. Ultrasonography was used to determine muscle cross-sectional area (CSA), subcutaneous fat (sFAT), and echo intensity (EI). MU behavior was assessed during isometric muscle actions at 20% and 50% of maximal voluntary contraction (MVC) by analyzing electromyography amplitude (EMG RMS ) and relationships between mean firing rates (MFR), recruitment thresholds (RT), and MU action potential amplitudes (MUAP size ) and durations (MUAP time ). The OW group had significantly greater EI than the NW group ( P = 0.002; NW, 47.99 ± 6.01 AU; OW, 58.90 ± 10.63 AU, where AU is arbitrary units) with no differences between groups for CSA ( P = 0.688) or MVC force ( P = 0.790). MUAP size was larger for NW than OW in relation to RT ( P = 0.002) and for MUs expressing similar MFRs ( P = 0.011). There were no significant differences ( P = 0.279-0.969) between groups for slopes or y-intercepts from the MFR vs. RT relationships. MUAP time was larger in OW ( P = 0.015) and EMG RMS was attenuated in OW compared with NW ( P = 0.034); however, there were no significant correlations ( P = 0.133-0.164, r = 0.270-0.291) between sFAT and EMG RMS . In a muscle that does not support body mass, the OW children had smaller MUAP size as well as greater EI, although anatomical CSA was similar. This contradicts previous studies examining larger limb muscles. Despite evidence of smaller MUs, the OW children had similar isometric strength compared with NW children. NEW & NOTEWORTHY Ultrasound data and motor unit action potential sizes suggest that overweight children have poorer muscle composition and smaller motor units in the first dorsal interosseous than normal weight children. Evidence is presented that suggests differences in action potential size cannot be explained by differences in subcutaneous fat alone.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hampden Kuhns; Eladio M. Knipping; Jeffrey M. Vukovich,
2005-05-01
The Big Bend Regional Aerosol and Visibility Observational (BRAVO) Study investigated the sources of haze at Big Bend National Park in southwest Texas. The modeling domain includes most of the continental United States and Mexico. The BRAVO emissions inventory was constructed from the 1999 National Emission Inventory for the United States, modified to include finer-resolution data for Texas and 13 U.S. states in close proximity. The inventory includes emissions for CO, nitrogen oxides, sulfur dioxide, volatile organic compounds (VOCs), ammonia, particulate matter (PM) {lt}10 {mu}m in aerodynamic diameter, and PM {lt}2.5 {mu}m in aerodynamic diameter. The SMOKE modeling system wasmore » used to generate gridded emissions fields for use with the Regional Modeling System for Aerosols and Deposition (REMSAD) and the Community Multiscale Air Quality model modified with the Model of Aerosol Dynamics, Reaction, Ionization and Dissolution (CMAQ-MADRID). The compilation of the inventory, supporting model input data, and issues encountered during the development of the inventory are documented. A comparison of the BRAVO emissions inventory for Mexico with other emerging Mexican emission inventories illustrates their uncertainty. 65 refs., 4 figs., 9 tabs.« less
Pawar, Mohit; Kumar, Priyank; Sunkaraneni, Soujanya; Sirohi, Sunil; Walker, Ellen A; Yoburn, Byron C
2007-06-01
It has been proposed that opioid agonist efficacy may play a role in tolerance and the regulation of opioid receptor density. To address this issue, the present studies estimated the in vivo efficacy of three opioid agonists and then examined changes in spinal mu-opioid receptor density following chronic treatment in the mouse. In addition, tolerance and regulation of the trafficking protein dynamin-2 were determined. To evaluate efficacy, the method of irreversible receptor alkylation was employed and the efficacy parameter tau estimated. Mice were injected with the irreversible mu-opioid receptor antagonist clocinnamox (0.32-25.6 mg/kg, i.p), and 24 h later, the analgesic potency of s.c. morphine, oxycodone and etorphine were determined. Clocinnamox dose-dependently antagonized the analgesic effects of morphine, etorphine and oxycodone. The shift to the right of the dose-response curves was greater for morphine and oxycodone compared to etorphine and the highest dose of clocinnamox reduced the maximal effect of morphine and oxycodone, but not etorphine. The order of efficacy calculated from these results was etorphine>morphine>oxycodone. Other mice were infused for 7 days with oxycodone (10-150 mg/kg/day, s.c.) or etorphine (50-250 microg/kg/day, s.c.) and the analgesic potency of s.c. morphine determined. The low efficacy agonist (oxycodone) produced more tolerance than the high efficacy agonist (etorphine) at equi-effective infusion doses. In saturation binding experiments, the low efficacy opioid agonists (morphine, oxycodone) did not regulate the density of spinal mu-opioid receptors, while etorphine produced approximately 40% reduction in mu-opioid receptor density. Furthermore, etorphine increased spinal dynamin-2 abundance, while oxycodone did not produce any significant change in dynamin-2 abundance. Overall, these data indicate that high efficacy agonists produce less tolerance at equi-effective doses. Furthermore, increased efficacy was associated with mu-opioid receptor downregulation and dynamin-2 upregulation. Conversely, lower efficacy agonists produced more tolerance at equi-effective doses, but did not regulate mu-opioid receptor density or dynamin-2 abundance. Taken together, these studies indicate that agonist efficacy plays an important role in tolerance and regulation of receptors and trafficking proteins.
Paraskevopoulou, Patrina; Makedonas, Christodoulos; Psaroudakis, Nikolaos; Mitsopoulou, Christiana A; Floros, Georgios; Seressioti, Andriana; Ioannou, Marinos; Sanakis, Yiannis; Rath, Nigam; Gómez García, Carlos J; Stavropoulos, Pericles; Mertis, Konstantinos
2010-03-01
The novel trimolybdenum cluster [Mo(3)(mu(3)-Br)(2)(mu-Br)(3)Br(6)](2-) (1, {Mo(3)}(9+), 9 d-electrons) has been isolated from the reaction of [Mo(CO)(6)] with 1,2-C(2)H(4)Br(2) in refluxing PhCl. The compound has been characterized in solution by electrospray ionization mass spectrometry (ESI-MS), UV-vis spectroscopy, cyclic voltammetry, and in the solid state by X-ray analysis (counter-cations: (n-Bu)(4)N(+) (1), Et(4)N(+), Et(3)BzN(+)), electron paramagnetic resonance (EPR), magnetic susceptibility measurements, and infrared spectroscopy. The least disordered (n-Bu)(4)N(+) salt crystallizes in the monoclinic space group C2/c, a = 20.077(2) A, b = 11.8638(11) A, c = 22.521(2) A, alpha = 90 deg, beta = 109.348(4) deg, gamma = 90 deg, V = 5061.3(9) A(3), Z = 4 and contains an isosceles triangular metal arrangement, which is capped by two bromine ligands. Each edge of the triangle is bridged by bromine ions. The structure is completed by six terminal bromine ligands. According to the magnetic measurements and the EPR spectrum the trimetallic core possesses one unpaired electron. Electrochemical data show that oxidation by one electron of 1 is reversible, thus proceeding with retention of the trimetallic core, while the reduction is irreversible. The effective magnetic moment of 1 (mu(eff), 1.55 mu(B), r.t.) is lower than the spin-only value (1.73 mu(B)) for S = 1/2 systems, most likely because of high spin-orbit coupling of Mo(III) and/or magnetic coupling throughout the lattice. The ground electronic state of 1 was studied using density functional theory techniques under the broken symmetry formalism. The ground state is predicted to exhibit strong antiferromagnetic coupling between the three molybdenum atoms of the core. Moreover, our calculated data predict two broken symmetry states that differ only by 0.4 kcal/mol (121 cm(-1)). The antiferromagnetic character is delocalized over three magnetic orbitals populated by three electrons. The assignment of the infrared spectra is also provided.
Applied Meteorology Unit (AMU) Quarterly Report Fourth Quarter FY-04
NASA Technical Reports Server (NTRS)
Bauman, William; Wheeler, Mark; Lambert, Winifred; Case, Jonathan; Short, David
2004-01-01
This report summarizes the Applied Meteorology Unit (A MU) activities for the fourth quarter of Fiscal Year 2004 (July -Sept 2004). Tasks covered are: (1) Objective Lightning Probability Forecast: Phase I, (2) Severe Weather Forecast Decision Aid, (3) Hail Index, (4) Shuttle Ascent Camera Cloud Obstruction Forecast, (5) Advanced Regional Prediction System (ARPS) Optimization and Training Extension and (5) User Control Interface for ARPS Data Analysis System (ADAS) Data Ingest.
2012-09-01
scheduler to adapt its uplink and downlink assignments to channel conditions. Sleep mode is used by the MS to minimize power drain and radio...is addressed in one resource unit, while for multi-user (MU) schemes , multiple users can be scheduled in one resource unit. Open-loop techniques...17 7. Mobility and Power Management ......................................... 18 8. Scheduling Services
Krzeski, Erin; Harden, Samantha; Cook, Emily; Allen, Kacie; Estabrooks, Paul A.
2012-01-01
Despite strong scientific data indicating associations among sugar-sweetened beverages (SSB) and numerous adverse health outcomes, little is known about culturally specific beliefs and potential individual-level behavioral strategies to reduce SSB intake. The primary objective of this formative study targeting adults residing in rural southwest Virginia was to apply the Theory of Planned Behavior (TPB) to investigate culturally specific attitudes, subjective norms and perceived behavioral control constructs related to the consumption of SSB, water, and artificially sweetened beverages. Using a homogenous sampling strategy, eight focus groups were conducted with 54 adult participants who exceeded recommendations of <1 cup of SSB/day. An experienced moderator and co-moderator utilized a semi-structured script, grounded in the TPB, to execute the focus group. All focus groups were audio taped and transcribed verbatim. Three researchers independently coded meaning units (MU) to the major themes and subsequently met to gain consensus in coding. Important beverage specific themes emerged for attitudes, subjective norms, perceived behavioral control, and intentions. Across all beverages, the most notable themes included taste (n= 161 MU), availability/convenience (n= 95 MU), habit/addiction (n=57 MU), and cost (n= 28 MU). Health consequences associated with beverages and water quality issues also surfaced, as well as normative beliefs including the influence of doctors and peers. The identified themes and sub-themes provides critical insight into understanding culturally-relevant context and beliefs associated with beverage behaviors and helps inform the development and evaluation of future intervention efforts targeting SSB consumption in the health disparate region of southwest Virginia. PMID:23102176
Jamema, S V; Upreti, R R; Sharma, S; Deshpande, D D
2008-09-01
The purpose of this work is to report the results of commissioning and to establish a quality assurance (QA) program for commercial 3D treatment planning system (TPS) based on IAEA Technical Report Series 430. Eclipse v 7.3.10, (Varian Medical Systems, Palo Alto, CA, U.S.A.) TPS was commissioned for a Clinac 6EX (Varian Medical Systems, Palo Alto, CA, USA) linear accelerator. CT images of a phantom with various known in-homogeneities were acquired. The images were transferred to TPS and tested for various parameters related to patient data acquisition, anatomical modeling, plan evaluation and dose calculation. Dosimetric parameters including open, asymmetric and wedged shaped fields, oblique incidence, buildup region behavior and SSD dependence were evaluated. Representative clinical cases were tested for MU calculation and point doses. The maximum variation between the measured and the known CT numbers was 20 +/- 11.7 HU (1 SD). The results of all non-dosimetric tests were found within tolerance, however expansion at the sharp corners was found distorted. The accuracy of the DVH calculations depends on the grid size. TPS calculations of all the dosimetric parameters were in good agreement with the measured values, however for asymmetric open and wedged fields, few points were found out of tolerance. Smaller grid size calculation showed better agreement of dose calculation in the build-up region. Independent tests for MU calculation showed a variation within +/-2% (relative to planning system), meanwhile variation of 3.0% was observed when the central axis was blocked. The test results were in agreement with the tolerance specified by IAEA TRS 430. A subset of the commissioning tests has been identified as a baseline data for an ongoing QA program.
NASA Astrophysics Data System (ADS)
Shu, Lei
Some filled skutterudite compounds have recently been found to exhibit very interesting properties. The first Pr-based heavy-fermion superconductor, PrOs4Sb12, is an intriguing material due to the unusual properties of both its normal and superconducting states. Comprehensive muon spin rotation and relaxation studies and magnetic susceptibility measurements, described in this dissertation, have been performed to investigate the microscopic properties of PrOs4Sb12 and its Ru and La doped alloys. The temperature dependence of penetration depth measured in the vortex state of PrOs4Sb12 using transverse-field muon spin rotation (TF-muSR) is weaker than those measured by radiofrequency measurements. A scenario based on two-band superconductivity in PrOs4Sb 12, is proposed to resolve this difference. TF-muSR experiments also suggest the suppression of superfluid density with Ru doping, probably due to impurity scattering. In addition, magnetic susceptibility data as well as analysis of the muSR data in PrOs4Sb12 reveal a nearly linear relation of mu+ Knight shift vs. magnetic susceptibility. This suggests that the muon charge does not affect the crystalline electric field splitting of Pr3+ near neighbors. Additional evidence comes from the fact that the superconducting transition temperature Tc measured from muSR is consistent with the bulk superconducting values. Zero-field muon spin relaxation (ZF-muSR) experiments have been carried out in the Pr(Os1-xRux) 4Sb12 and Pr1-yLayOs 4Sb12 alloy systems to investigate the time-reversal symmetry (TRS) breaking found in an earlier ZF-muSR study of the end compound PrOs 4Sb12. The results from measurements at KEK, Japan, suggest that Ru doping is considerably more efficient than La doping in suppressing TRS breaking superconducting in PrOs4Sb12. However, we think that the spontaneous local field that indicates TRS breaking detected by ZF-muSR may depend on sample quality if those fields are from inhomogeneity in the superconducting order parameter, since our ZF-muSR experiment detects nonzero spontaneous fields for Pr(Os0.9Ru0.1)4 Sb12 from measurement at ISIS, United Kingdom in different samples. Longitudinal-field muon spin relaxation experiments also have been carried out to elucidate the anomalous dynamic muon spin relaxation detected by ZF-muSR in those alloys. The dynamic muon relaxation found in the alloys appears to be due to 141Pr nuclear spin fluctuations, where the 141Pr moments are enhanced by hyperfine coupling to the Pr 3+ Van Vleck susceptibility.
Toddlers' choice: Yo-Yoing diabetes control or deci-unit insulin dosing?
Abul-Ainine, Sarah Aa; Abul-Ainine, Ahmad Aa
2012-02-15
While the incidence of toddlers' diabetes is soaring, their mainstay insulins were withdrawn, namely the weak 10% or 20% insulin mixtures (WIM), which were injected only once or twice daily. Consequently, toddlers are coerced to use an insulin pump, multi-dose insulin regime (MuDIR), mix or dilute insulins. This paper highlights the difficulties and proposes a simple solution. While an insulin pump is the best available option, it is not readily available for everyone. Mixing insulins is not sufficiently precise in small doses. Although diluting insulin would allow precise dosing and reduce the dose variability secondary to dribbling after injections, it, like insulin mixing, deprives children from using the pen and related child-friendly accessories. In MuDIR, we inject 4-5 small doses of insulin instead of 1-2 daily larger doses of WIM. Thus, on using a half unit (½unit) insulin pen, a dose of 0.5, 1, 1.5 and 2 units are adjusted in steps of 100%, 50%, 33% or 25%; unlike the advisable 5%-20%. This does not easily match the tiny erratic meals of grazing toddlers. Maternal anxiety peaks on watching yo-yoing glycemia. Carers have to accept either persistently high sugar or wild fluctuation. The risks of such poor glycemic pattern are increasingly recognized. Using insulin U20 in a ½unit disposable pen allows deci-unit dosing, with 5%-20% dose-tuning, greater accuracy on delivering small doses and reduction of dose variability from dribbling. Deci-unit dosing may help avoid wide glycemic swings and provide the affordable alternative to insulin pumps for toddlers. Deci-unit pen materializes the Human Rights of Children, a safer and effective treatment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCullough, D.A.; Minshall, G.W.; Cushing, C.E.
1979-06-01
This study derives a set of bioenergetic parameters for the blackfly Simulium spp. (Diptera: Simuliidae) and the caddisfly Hydropsyche occidentalis (Trichoptera: Hydropsychidae) and evaluates the impact of these filter feeders on the lotic environment. In addition, comparison is made between field- and laboratory-derived estimates of ingestion and between 2 methods of calculating assimilation rate. Digestion (gut-clearance) time for Simulium ranged between 0.33 and 1.25 h compared to 1.54 to 2.63 h for Hydropsyche. Mean ingestion rate for Simulium in a series of experiments ranged from 1.36 to 54.74 ..mu..g DW/mg DW/h. The mean assimilation efficiency for diatoms was about 55%more » as measured by the dual-label technique. Mean ingestion rates of diatoms for Hydropsyche in 3 experiments were 31.3, 31.0 and 29.2 ..mu..g DW/mg DW/h, respectively; low values (3 ..mu..g DW/mg DW/h) from a 4th experiment were associated with high concentrations of green algae. An assimilation rate for diatoms of 7.5 ..mu..g AFDW/mg DW/h was derived for Hydropsyche. Measurements of growth rates of Hydropsyche under natural conditions were 3.6 to 4.4 ..mu..g DW/mg DW/h. Respiration rate of Hydropsyche for water greater than or equal to 62% O/sub 2/ saturation was about 2.3 ..mu..l O/sub 2//mg DW/h at 20/sup 0/C. The results of this research in combination with literature derived values, yielded the following mean energy budgets for Simulium and Hydropsyche, respectively(J/mg/h): ingestion (C) 0.318, 0.393; respiration (R) 0.092, 0.042; growth (G) 0.092, 0.100; assimilation (A) (as C x AE) 0.182, 0.192; (as G + R) 0.184, 0.142 (values times 0.239 = cal/mg/h).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tanimoto, Daigo, E-mail: daigoro@med.kawasaki-m.ac.jp; Ito, Katsuyoshi; Yamamoto, Akira
2010-10-15
This study was designed to evaluate the intravascular transformation behavior of superabsorbent polymer microsphere (SAP-MS) in vivo macroscopically by using monochromatic X-ray imaging and to quantitatively compare the expansion rate of SAP-MS among different kinds of mixtures. Fifteen rabbits were used for our study and transcatheter arterial embolization (TAE) was performed for their auricular arteries using monochromatic X-ray imaging. We used three kinds of SAP-MS (particle diameter 100-150 {mu}m) mixture as embolic spherical particles: SAP-MS(H) absorbed with sodium meglumine ioxaglate (Hexabrix 320), SAP-MS(V) absorbed with isosmolar contrast medium (Visipaque 270), and SAP-MS(S) absorbed with 0.9% sodium saline. The initial volumemore » of SAP-MS particles just after TAE and its final volume 10 minutes after TAE in the vessel were measured to calculate the expansion rate (ER) (n = 30). Intravascular behavior of SAP-MS particles was clearly observed in real time at monochromatic X-ray imaging. Averaged initial volumes of SAP-MS (H) (1.24 x 10{sup 7} {mu}m{sup 3}) were significantly smaller (p < 0.001) than those of SAP-MS (V) (5.99 x 10{sup 7} {mu}m{sup 3}) and SAP-MS (S) (5.85 x 10{sup 7} {mu}m{sup 3}). Averaged final volumes of SAP-MS (H) were significantly larger than averaged initial volumes (4.41 x 10{sup 7} {mu}m{sup 3} vs. 1.24 x 10{sup 7} {mu}m{sup 3}; p < 0.0001, ER = 3.55). There were no significant difference between averaged final volumes and averaged initial volumes of SAP-MS (V) and SAP-MS (S). SAP-MS (H), which first travels distally, reaches to small arteries, and then expands to adapt to the vessel lumen, is an effective particle as an embolic agent, causing effective embolization.« less
Leung, Gary N W; Ho, Emmie N M; Kwok, W Him; Leung, David K K; Tang, Francis P W; Wan, Terence S M; Wong, April S Y; Wong, Colton H F; Wong, Jenny K Y; Yu, Nola H
2007-09-07
Quantitative determination, particularly for threshold substances in biological samples, is much more demanding than qualitative identification. A proper assessment of any quantitative determination is the measurement uncertainty (MU) associated with the determined value. The International Standard ISO/IEC 17025, "General requirements for the competence of testing and calibration laboratories", has more prescriptive requirements on the MU than its superseded document, ISO/IEC Guide 25. Under the 2005 or 1999 versions of the new standard, an estimation of the MU is mandatory for all quantitative determinations. To comply with the new requirement, a protocol was established in the authors' laboratory in 2001. The protocol has since evolved based on our practical experience, and a refined version was adopted in 2004. This paper describes our approach in establishing the MU, as well as some other important considerations, for the quantification of threshold substances in biological samples as applied in the area of doping control for horses. The testing of threshold substances can be viewed as a compliance test (or testing to a specified limit). As such, it should only be necessary to establish the MU at the threshold level. The steps in a "Bottom-Up" approach adopted by us are similar to those described in the EURACHEM/CITAC guide, "Quantifying Uncertainty in Analytical Measurement". They involve first specifying the measurand, including the relationship between the measurand and the input quantities upon which it depends. This is followed by identifying all applicable uncertainty contributions using a "cause and effect" diagram. The magnitude of each uncertainty component is then calculated and converted to a standard uncertainty. A recovery study is also conducted to determine if the method bias is significant and whether a recovery (or correction) factor needs to be applied. All standard uncertainties with values greater than 30% of the largest one are then used to derive the combined standard uncertainty. Finally, an expanded uncertainty is calculated at 99% one-tailed confidence level by multiplying the standard uncertainty with an appropriate coverage factor (k). A sample is considered positive if the determined concentration of the threshold substance exceeds its threshold by the expanded uncertainty. In addition, other important considerations, which can have a significant impact on quantitative analyses, will be presented.
Characterization of deltamethrin metabolism by rat plasma and liver microsomes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anand, Sathanandam S.; Bruckner, James V.; Haines, Wendy T.
2006-04-15
Deltamethrin, a widely used type II pyrethroid insecticide, is a relatively potent neurotoxicant. While the toxicity has been extensively examined, toxicokinetic studies of deltamethrin and most other pyrethroids are very limited. The aims of this study were to identify, characterize, and assess the relative contributions of esterases and cytochrome P450s (CYP450s) responsible for deltamethrin metabolism by measuring deltamethrin disappearance following incubation of various concentrations (2 to 400 {mu}M) in plasma (esterases) and liver microsomes (esterases and CYP450s) prepared from adult male rats. While the carboxylesterase metabolism in plasma and liver was characterized using an inhibitor, tetra isopropyl pyrophosphoramide (isoOMPA), CYP450more » metabolism was characterized using the cofactor, NADPH. Michaelis-Menten rate constants were calculated using linear and nonlinear regression as applicable. The metabolic efficiency of these pathways was estimated by calculating intrinsic clearance (Vmax/Km). In plasma, isoOMPA completely inhibited deltamethrin biotransformation at concentrations (2 and 20 {mu}M of deltamethrin) that are 2- to 10-fold higher than previously reported peak blood levels in deltamethrin-poisoned rats. For carboxylesterase-mediated deltamethrin metabolism in plasma, Vmax = 325.3 {+-} 53.4 nmol/h/ml and Km = 165.4 {+-} 41.9 {mu}M. Calcium chelation by EGTA did not inhibit deltamethrin metabolism in plasma or liver microsomes, indicating that A-esterases do not metabolize deltamethrin. In liver microsomes, esterase-mediated deltamethrin metabolism was completely inhibited by isoOMPA, confirming the role of carboxylesterases. The rate constants for liver carboxylesterases were Vmax = 1981.8 {+-} 132.3 nmol/h/g liver and Km = 172.5 {+-} 22.5 {mu}M. Liver microsomal CYP450-mediated biotransformation of deltamethrin was a higher capacity (Vmax = 2611.3 {+-} 134.1 nmol/h/g liver) and higher affinity (Km = 74.9 {+-} 5.9 {mu}M) process than carboxylesterase (plasma or liver) detoxification. Genetically engineered individual rat CYP450s (Supersomes) were used to identify specific CYP450 isozyme(s) involved in the deltamethrin metabolism. CYP1A2, CYP1A1, and CYP2C11 in decreasing order of importance quantitatively, metabolized deltamethrin. Intrinsic clearance by liver CYP450s (35.5) was more efficient than that by liver (12.0) or plasma carboxylesterases (2.4)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xun, Pengcheng; Bujnowski, Deborah; Department of Epidemiology, Gillings School of Global Public Health, University of North Carolina at Chapel Hill, Chapel Hill, NC
Background: Data on selenium (Se) levels in American young adults, especially in African Americans, are lacking. Objective: This study presented toenail Se distributions in American young adults of both genders, including both Caucasians and African Americans; and explored potential predictors of toenail Se levels. Data and methods: Data from the Coronary Artery Risk Development in Young Adults study among 4252 American young adults, aged 20-32 in 1987 was used to examine toenail Se levels by instrumental neutron-activation analysis. The distribution of Se levels was described and multivariable linear regression was used to examine potential modifiers of toenail Se concentration withinmore » ethnicity-gender subgroups. Results: The geometric mean of toenail Se in this cohort was 0.844 {mu}g/g (95% CI, 0.840-0.849 {mu}g/g) and the median was 0.837 {mu}g/g (95% CI, 0.833-0.844 {mu}g/g). Median levels from lowest to highest quintile were 0.691, 0.774, 0.838, 0.913 and 1.037 {mu}g/g. Se levels varied geographically, and were generally in accordance with its concentrations in local soil. Males, African Americans, current smokers, heavy drinkers and less educated participants were more likely to have low Se levels. Conclusion: This study suggests that toenail Se levels vary geographically depending on soil Se concentrations. In addition to gender, ethnicity and education level, smoking status and alcohol consumption are two important indicators of Se status since they are modifiable lifestyle factors. Findings from this study might aid public health professionals in identifying people at relatively high or low Se levels, so that chronic disease prevention efforts can be directed toward these subgroups. - Research highlights: {yields} Average of toenail Se levels in this cohort was 0.844 {mu}g/g (95% CI, 0.840-0.849 {mu}g/g). {yields} Toenail Se levels vary geographically depending on soil Se concentrations. {yields} Males, African Americans and less educated participants have low Se levels. {yields} Smoking status and alcohol consumption are two important indicators of Se status.« less
Comparison of elliptical and spherical mirrors for the grasshopper monochromators at SSRL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Waldhauer, A. P.
1989-07-01
A comparison of the performance of a spherical and elliptical mirror in the grasshopper monochromator is presented. The problem was studied by ray tracing and then tested using visible (/lambda/=633 nm) laser light. Calculations using ideal optics yield an improvement in flux by a factor of up to 2.7, while tests with visible light show an increase by a factor of 5 because the old spherical mirror is compared to a new, perfect elliptical one. The FWHM of the measured focus is 90 /mu/m with a spherical mirror, and 25 /mu/m with an elliptical one. Elliptical mirrors have been acquiredmore » and are now being installed in the two grasshoppers at SSRL.« less
Lauber, Benedikt; Lichtwark, Glen A; Cresswell, Andrew G
2014-06-01
While medial gastrocnemius (MG) and soleus (SOL) are considered synergists, they are anatomically exclusive in that SOL crosses only the ankle, while MG crosses both the knee and ankle. Due to the force-length properties of both active and passive structures, activation of SOL and MG must be constantly regulated to provide the required joint torques for any planned movement. As such, the aim of this study was to investigate the neural regulation of MG and SOL when independently changing their length by changing only the knee joint angle, thus exclusively altering the length of MG fibers. MG and SOL motor units (MU) were recorded intramuscularly along with ultrasound imaging of MG and SOL fascicle lengths, while moving the knee through 60° of rotation and maintaining a low level of voluntary plantar flexor torque. The results showed a reciprocal activation of MG and SOL as the knee was moved into flexion and extension. A clear reduction in MG MU firing rates occurred as the knee was flexed (MG fascicles shortening), with de-recruitment of most MG MU occurring at close to full knee flexion. A concomitant increase in SOL MU activity was observed while no change in the length of its fascicles was found. The opposite effects were found when the knee was moved into extension. A strong correlation (ICC = 0.78) was found between the fascicle length at which MG MUs were de-recruited and subsequently re-recruited. This was stronger than the relationship of de-recruitment and re-recruitment with knee angle (ICC = 0.52), indicating that in this instance, muscle fascicle length rather than joint angle is more influential in regulating MG recruitment. Such a reciprocal arrangement like the one presented here for SOL and MG is essential for human voluntary movements such as walking or cycling. © 2014 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.
DOE Office of Scientific and Technical Information (OSTI.GOV)
C Hann; M Bentley; A Vercnocke
2011-12-31
The site of outflow resistance leading to elevated intraocular pressure in primary open-angle glaucoma is believed to be located in the region of Schlemm's canal inner wall endothelium, its basement membrane and the adjacent juxtacanalicular tissue. Evidence also suggests collector channels and intrascleral vessels may have a role in intraocular pressure in both normal and glaucoma eyes. Traditional imaging modalities limit the ability to view both proximal and distal portions of the trabecular outflow pathway as a single unit. In this study, we examined the effectiveness of three-dimensional micro-computed tomography (3D micro-CT) as a potential method to view the trabecularmore » outflow pathway. Two normal human eyes were used: one immersion fixed in 4% paraformaldehyde and one with anterior chamber perfusion at 10 mmHg followed by perfusion fixation in 4% paraformaldehyde/2% glutaraldehyde. Both eyes were postfixed in 1% osmium tetroxide and scanned with 3D micro-CT at 2 {mu}m or 5 {mu}m voxel resolution. In the immersion fixed eye, 24 collector channels were identified with an average orifice size of 27.5 {+-} 5 {mu}m. In comparison, the perfusion fixed eye had 29 collector channels with a mean orifice size of 40.5 {+-} 13 {mu}m. Collector channels were not evenly dispersed around the circumference of the eye. There was no significant difference in the length of Schlemm's canal in the immersed versus the perfused eye (33.2 versus 35.1 mm). Structures, locations and size measurements identified by 3D micro-CT were confirmed by correlative light microscopy. These findings confirm 3D micro-CT can be used effectively for the non-invasive examination of the trabecular meshwork, Schlemm's canal, collector channels and intrascleral vasculature that comprise the distal outflow pathway. This imaging modality will be useful for non-invasive study of the role of the trabecular outflow pathway as a whole unit.« less
Lynch, Kimberly; Kendall, Mat; Shanks, Katherine; Haque, Ahmed; Jones, Emily; Wanis, Maggie G; Furukawa, Michael; Mostashari, Farzad
2014-02-01
Assess the Regional Extension Center (REC) program's progress toward its goal of supporting over 100,000 providers in small, rural, and underserved practices to achieve meaningful use (MU) of an electronic health record (EHR). Data collected January 2010 through June 2013 via monitoring and evaluation of the 4-year REC program. Descriptive study of 62 REC programs. Primary data collected from RECs were merged with nine other datasets, and descriptive statistics of progress by practice setting and penetration of targeted providers were calculated. RECs recruited almost 134,000 primary care providers (PCPs), or 44 percent of the nation's PCPs; 86 percent of these were using an EHR with advanced functionality and almost half (48 percent) have demonstrated MU. Eighty-three percent of Federally Qualified Health Centers and 78 percent of the nation's Critical Access Hospitals were participating with an REC. RECs have made substantial progress in assisting PCPs with adoption and MU of EHRs. This infrastructure supports small practices, community health centers, and rural and public hospitals to use technology for care delivery transformation and improvement. © Health Research and Educational Trust.
Time for pulse traversal through slabs of dispersive and negative ({epsilon}, {mu}) materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nanda, Lipsa; Ramakrishna, S. Anantha
2007-12-15
The traversal times for an electromagnetic pulse traversing a slab of dispersive and dissipative material with negative dielectric permittivity ({epsilon}) and magnetic permeability ({mu}) have been calculated by using the average flow of electromagnetic energy in the medium. The effects of bandwidth of the pulse and dissipation in the medium have been investigated. While both large bandwidth and large dissipation have similar effects in smoothening out the resonant features that appear due to Fabry-Perot resonances, large dissipation can result in very small or even negative traversal times near the resonant frequencies. We have also investigated the traversal times and Wignermore » delay times for obliquely incident pulses and evanescent pulses. The coupling to slab plasmon-polariton modes in frequency ranges with negative {epsilon} or {mu} is shown to result in large traversal times at the resonant conditions. We also find that the group velocity mainly contributes to the delay times for pulses propagating across a slab with n=-1. We have checked that the traversal times are positive and subluminal for pulses with sufficiently large bandwidths.« less
Barral, M C; Jiménez-Aparicio, R; Pérez-Quintanilla, D; Priego, J L; Royer, E C; Torres, M R; Urbanos, F A
2000-01-10
The reaction of Ru2Cl(mu-O2CMe)4 with 2,4-hexadienoic and 2-methoxyacetic acids affords the compounds Ru2Cl(mu-O2CR)4 [R = CH=CHCH=CHCH3 (1), CH2OMe (2)]. The structures of both complexes have been determined by X-ray crystallography. 1 crystallizes in the triclinic space group P-1 with a = 9.264(1) A, b = 12.661(8) A, c = 12.839(5) A, alpha = 106.09(3) degrees, beta = 77.89(2) degrees, gamma = 97.73(3) degrees, and Z = 2. 2 crystallizes in the nonstandard monoclinic space group P2(1)/c with a = 12.132(4) A, b = 11.570(2) A, c = 13.674(2) A, beta = 91.18(2) degrees, and Z = 4. Complexes 1 and 2 show [Ru2(mu-O2CR)4]+ units linked by chloride ions, giving zigzag chains with Ru-Cl-Ru angles of 119.43(4) degrees and 110.11(7) degrees, respectively. The Ru-Ru bond distances are 2.2857(9) A (1) and 2.290(1) A (2). A magnetic study, in the 2-300 K temperature range, of the new compounds and the previously described Ru2Cl(mu-O2CR)4 [R = CHMe2 (3), CMe3 (4), C4H4N (5)] is described. The polymeric complexes 1 and 2 and the nonpolymeric 3-5 show a large zero-field splitting which varies from 53.9 to 68.1 cm-1. These complexes also show a weak, but not negligible, through-space intermolecular antiferromagnetic coupling not observed in the previous magnetic studies carried out on these types of compounds.
NASA Astrophysics Data System (ADS)
Cheong, Kwang-Ho; Lee, Me-Yeon; Kang, Sei-Kwon; Yoon, Jai-Woong; Park, Soah; Hwang, Taejin; Kim, Haeyoung; Kim, Kyoung Ju; Han, Tae Jin; Bae, Hoonsik
2015-07-01
The aim of this study is to set up statistical quality control for monitoring the volumetric modulated arc therapy (VMAT) delivery error by using the machine's log data. Eclipse and a Clinac iX linac with the RapidArc system (Varian Medical Systems, Palo Alto, USA) are used for delivery of the VMAT plan. During the delivery of the RapidArc fields, the machine determines the delivered monitor units (MUs) and the gantry angle's position accuracy and the standard deviations of the MU ( σMU: dosimetric error) and the gantry angle ( σGA: geometric error) are displayed on the console monitor after completion of the RapidArc delivery. In the present study, first, the log data were analyzed to confirm its validity and usability; then, statistical process control (SPC) was applied to monitor the σMU and the σGA in a timely manner for all RapidArc fields: a total of 195 arc fields for 99 patients. The MU and the GA were determined twice for all fields, that is, first during the patient-specific plan QA and then again during the first treatment. The sMU and the σGA time series were quite stable irrespective of the treatment site; however, the sGA strongly depended on the gantry's rotation speed. The σGA of the RapidArc delivery for stereotactic body radiation therapy (SBRT) was smaller than that for the typical VMAT. Therefore, SPC was applied for SBRT cases and general cases respectively. Moreover, the accuracy of the potential meter of the gantry rotation is important because the σGA can change dramatically due to its condition. By applying SPC to the σMU and σGA, we could monitor the delivery error efficiently. However, the upper and the lower limits of SPC need to be determined carefully with full knowledge of the machine and log data.
Stress Reconstruction Analysis of Wheel Saw Cut Tests and Evaluation of Reconstruction Procedure
DOT National Transportation Integrated Search
1993-09-01
The report is the fourth in a series of engineering studies on railroad vehicle wheel performance. The results of saw cut tests performed on one new and one used wheel designed for a fleet of multiple unit (MU) power cars are summarized and analyzed....
Ranking of Air Force Heating Plants Relative to the Economic Benefit of Coal Utilization
1989-11-01
HTlW Output Capacity ..................... 27 5.2.2 Combustion Technologies ......................... 31 5.3 COMPUTER MODEL FOR LCC ANALISIS ...and field-erected units have been examined. The packaged units are factory -built, shell (fire-tube) boilers that are small enotgh to be shipped by...40 HBtMu/h with a thermal energy capacity factory of about 65% if used as a baseload heating plant. A water- tube boiler with a steam rating of 1200
A Simulation Program with Latency Exploitation for the Transient Analysis of Digital Circuits.
1983-08-01
PW PER) Examples: VIN 3 0 PULSE(-5 5 iNS iNS iNS 50NS lOONS) parameters default values units Vi (initial value) volts or amps V2 (pulsed value) volts...TAUl TD2 TAU2)mU Examples: VIN 3 0 EXP(-5 0 2NS 30NS 60NS 40NS) parameters default values units V1 (initial value) volts or amps V2 (pulsed value
/sup 3/H-PAF-acether displacement and inhibition of binding in intact human platelets by BN 52021
DOE Office of Scientific and Technical Information (OSTI.GOV)
Korth, R.; Le Couedic, J.P.; Benveniste, J.
1986-03-05
Intact washed human platelets incubated at 20/sup 0/C in Tyrode's buffer containing 0.25% (w/v) bovine serum albumin bound /sup 3/H paf-acether in a concentration (0-6.5 nM) and time (0-60 min) dependent manner (n=3). BN 52021 (60 ..mu..M) a chemically defined extract from Ginkgo biloba inhibited the binding of increasing concentrations of /sup 3/H paf-acether. Calculated differences between /sup 3/H paf-acether binding in the presence or absence of BN 52021 (60 ..mu..M) reached nearly a plateau in concentrations higher than 0.65 nM /sup 3/H paf-acether. Increasing concentrations of BN 52021 (0-60 ..mu..M) as well as of unlabelled paf-acether (0-50 nM) preventedmore » within 15 min /sup 3/H paf-acether binding (0.65 nM) to platelets in a concentration-dependent way. Increasing BN 52021 concentrations (0-60 ..mu..M) also displaced platelet-bound /sup 3/H paf-acether (0.65 nM) in a concentration-dependent way. Displacement increased with the time length of platelet incubation with BN 52021 and reached a plateau at 15 min. Platelet-bound /sup 3/H paf-acether displacement of 28.3 +/- 6.3%, 31.1 +/- 4.0% and 26.7 +/- 5.6% was observed using 50 nM unlabelled paf-acether, 60 ..mu..M BN 52021 or both substances together (vs 4.3 +/- 7.2% for vehicle alone). No degradation of /sup 3/H paf-acether occurred as assessed by high pressure liquid chromatography. These results demonstrate that BN 52021 competes directly with paf-acether binding sites on human platelets.« less
Alborés, Pablo; Seeman, Johanna; Rentschler, Eva
2009-10-07
The synthesis, crystal structure, and magneto-chemical characterization of two new unprecedented -phenoxo--carboxylato heterodinuclear complexes based on the Cr(salen) moiety (salen = N,N-bis(salicylidene)ethylenediamine), [MII(O2C(CH3)3)(OH2)2(mu-O2C(CH3)3)(-salen)CrIII(O2C(CH3)3)], M = Ni (2), Co(3) are reported. The dinuclear complexes were obtained starting from the mononuclear trans-[Cr(salen)(CN)2]PPh4 (1), whose crystal structure is also reported. They show a trans arrangement of the Cr(salen) unit, bridging through the phenolate O atoms to a second metal center. An additional 2-O2-carboxylato bridge and a further monodentating carboxylate ligand complete the roughly octahedral Cr(III) coordination sphere. The highly distorted octahedral M(II) coordination environment is completed by two coordinated water molecules and an additional monodentating carboxylate. Variable-temperature solid-state DC magnetization studies were carried out in the 2.0-300 K range. Ferromagnetic isotropic pairwise exchange parameters were found with values of J = 4.1 cm-1 (2) and J = 2.1 cm-1 (3). Additionally, for complex 3, a ZFS parameter, D, was employed to properly fit the experimental data. Magnetization (M) vs. field (H) and temperature (T) data further support the presence of this anisotropic component and confirm ground states S = 5/2 and S = 3 for 2 and 3, respectively. Broken symmetry DFT calculations properly reproduce the experimental J values supporting the ferromagnetic exchange interaction experimentally observed. No out of phase susceptibility signal was observed in 0 DC magnetic field for both complexes. However, in the case of complex 3 a non-zero is observed when a small external field is applied below 3 K, suggesting slow relaxation of the magnetization which at 0 DC field is suppressed, probably due to efficient tunnelling relaxation pathways. The low symmetry of the Co(II) site in complex 3 may lead to the presence of transversal anisotropic components which could be responsible for the enhanced tunnelling pathway.
Cutting work in thick section cryomicrotomy.
Saubermann, A J; Riley, W D; Beeuwkes, R
1977-09-01
The forces during cryosectioning were measured using miniature strain gauges attached to a load cell fitted to the drive arm of the Porter-Blum MT-2 cryomicrotome. Work was calculated and the data normalized to a standard (1 mm X 1 mm X 0.5 micrometer) section. Thermal energy generated was also calculated. Five parameters were studied: cutting angle, thickness, temperature, hardness, and block shape. Force patterns could be divided into three major groups thought to represent cutting (Type I), large fracture planes greater than 10 micrometer in length (Type II), and small fracture planes less than 10 micrometer in length (Type III). Type I and Type II produced satisfactory sections. Work in cutting ranged from an average of 78.4 muJ to 568.8 muJ. Cutting angle and temperature had the greatest effect on sectioning. Heat generated would be sufficient to cause through-section melting for 0.5 micrometer thick sections assuming the worst possible case, namely that all heat went into the section without loss. Presence of a Type II pattern (large fracture pattern) is thought to be presumptive evidence against thawing.
NASA Astrophysics Data System (ADS)
Merker, L.; Kirchner, S.; Muñoz, E.; Costi, T. A.
2014-08-01
The Comment of A. A. Aligia claims that the superperturbation theory (SPT) approach [E. Muñoz, C. J. Bolech, and S. Kirchner, Phys. Rev. Lett. 110, 016601 (2013), 10.1103/PhysRevLett.110.016601] formulated using dual fermions [A. N. Rubtsov, M. I. Katsnelson, and A. I. Lichtenstein, Phys. Rev. B 77, 033101 (2008), 10.1103/PhysRevB.77.033101] and used by us to compare with numerical renormalization group (NRG) results for the conductance [L. Merker, S. Kirchner, E. Muñoz, and T. A. Costi, Phys. Rev. B 87, 165132 (2013), 10.1103/PhysRevB.87.165132], fails to correctly extend the results of the symmetric Anderson impurity model (SIAM) for general values of the local level Ed in the Kondo regime. We answer this criticism. We also compare new NRG results for cB, with cB calculated directly from the low-field conductance, with new higher-order SPT calculations for this quantity, finding excellent agreement for all Ed and for U /πΔ extending into the strong coupling regime.
Vacuum Stress in Schwarzschild Spacetime
NASA Astrophysics Data System (ADS)
Howard, Kenneth Webster
Vacuum stress in the conformally invariant scalar field in the region exterior to the horizon of a Schwarzschild black hole is examined. In the Hartle-Hawking vacuum state <(phi)('2)> and
Single-user MIMO versus multi-user MIMO in distributed antenna systems with limited feedback
NASA Astrophysics Data System (ADS)
Schwarz, Stefan; Heath, Robert W.; Rupp, Markus
2013-12-01
This article investigates the performance of cellular networks employing distributed antennas in addition to the central antennas of the base station. Distributed antennas are likely to be implemented using remote radio units, which is enabled by a low latency and high bandwidth dedicated link to the base station. This facilitates coherent transmission from potentially all available antennas at the same time. Such distributed antenna system (DAS) is an effective way to deal with path loss and large-scale fading in cellular systems. DAS can apply precoding across multiple transmission points to implement single-user MIMO (SU-MIMO) and multi-user MIMO (MU-MIMO) transmission. The throughput performance of various SU-MIMO and MU-MIMO transmission strategies is investigated in this article, employing a Long-Term evolution (LTE) standard compliant simulation framework. The previously theoretically established cell-capacity improvement of MU-MIMO in comparison to SU-MIMO in DASs is confirmed under the practical constraints imposed by the LTE standard, even under the assumption of imperfect channel state information (CSI) at the base station. Because practical systems will use quantized feedback, the performance of different CSI feedback algorithms for DASs is investigated. It is shown that significant gains in the CSI quantization accuracy and in the throughput of especially MU-MIMO systems can be achieved with relatively simple quantization codebook constructions that exploit the available temporal correlation and channel gain differences.
Simple apparatus for polarization sensing of analytes
NASA Astrophysics Data System (ADS)
Gryczynski, Zygmunt; Gryczynski, Ignacy; Lakowicz, Joseph R.
2000-09-01
We describe a simple device for fluorescence sensing based on an unexpansive light source, a dual photocell and a Watson bridge. The emission is detected from two fluorescent samples, one of which changes intensity in response to the analyte. The emission from these two samples is observed through two orthogonally oriented polarizers and an analyzer polarizer. The latter polarizer is rotated to yield equal intensities from both sides of the dual photocell, as determined by a zero voltage from the Watson bridge. Using this device, we are able to measure fluorescein concentration to an accuracy near 2% at 1 (mu) M fluorescein, and pH values accurate to +/- 0.02 pH units. We also use this approach with a UV hand lamp and a glucose-sensitive protein to measure glucose concentrations near 2 (mu) M to an accuracy of +/- 0.1 (mu) M. This approach requires only simple electronics, which can be battery powered. Additionally, the method is generic, and can be applied with any fluorescent sample that displays a change in intensity. One can imagine this approach being used to develop portable point-of-care clinical devices.
Hughes, Michael J; Mercier, Hélène P A; Schrobilgen, Gary J
2009-05-18
The adduct, (OsO(3)F(2))(2)2XeOF(4), was synthesized by dissolution of the infinite chain polymer, (OsO(3)F(2))(infinity), in XeOF(4) solvent at room temperature followed by removal of excess XeOF(4) under dynamic vacuum at 0 degrees C. Continued pumping at 0 degrees C resulted in removal of associated XeOF(4), yielding (OsO(3)F(2))(2), a new low-temperature phase of OsO(3)F(2). Upon standing at 25 degrees C for 1(1)/(2) h, (OsO(3)F(2))(2) underwent a phase transition to the known monoclinic phase, (OsO(3)F(2))(infinity). The title compounds, (OsO(3)F(2))(infinity), (OsO(3)F(2))(2), and (OsO(3)F(2))(2)2XeOF(4) have been characterized by low-temperature (-150 degrees C) Raman spectroscopy. Crystallization of (OsO(3)F(2))(2)2XeOF(4) from XeOF(4) solution at 0 degrees C yielded crystals suitable for X-ray structure determination. The structural unit contains the (OsO(3)F(2))(2) dimer in which the OsO(3)F(3) units are joined by two Os---F---Os bridges having fluorine bridge atoms that are equidistant from the osmium centers (2.117(5) and 2.107(4) A). The dimer coordinates to two XeOF(4) molecules through Os-F...Xe bridges in which the Xe...F distances (2.757(5) A) are significantly less than the sum of the Xe and F van der Waals radii (3.63 A). The (OsO(3)F(2))(2) dimer has C(i) symmetry in which each pseudo-octahedral OsO(3)F(3) unit has a facial arrangement of oxygen ligands with XeOF(4) molecules that are only slightly distorted from their gas-phase C(4v) symmetry. Quantum-chemical calculations using SVWN and B3LYP methods were employed to calculate the gas-phase geometries, natural bond orbital analyses, and vibrational frequencies of (OsO(3)F(2))(2), (OsO(3)F(2))(2)2XeOF(4), XeOF(4), OsO(2)F(4), and (mu-FOsO(3)F(2))(2)OsO(3)F(-) to aid in the assignment of the experimental vibrational frequencies of (OsO(3)F(2))(2), (OsO(3)F(2))(2)2XeOF(4), and (OsO(3)F(2))(infinity). The vibrational modes of the low-temperature polymeric phase, (OsO(3)F(2))(infinity), have been assigned by comparison with the calculated frequencies of (mu-FOsO(3)F(2))(2)OsO(3)F(-), providing more complete and reliable assignments than were previously available.
NASA Technical Reports Server (NTRS)
Horne, W. B.; Yager, T. J.; Sleeper, R. K.; Merritt, L. R.
1977-01-01
The stopping distance, brake application velocity, and time of brake application were measured for two modern jet transports, along with the NASA diagonal-braked vehicle and the British Mu-Meter on several runways, which when wetted, cover the range of slipperiness likely to be encountered in the United States. Tests were designed to determine if correlation between the aircraft and friction measuring vehicles exists. The test procedure, data reduction techniques, and preliminary test results obtained with the Boeing 727, the Douglas DC-9, and the ground vehicles are given. Time histories of the aircraft test run parameters are included.
Formation of large-scale structure from cosmic-string loops and cold dark matter
NASA Technical Reports Server (NTRS)
Melott, Adrian L.; Scherrer, Robert J.
1987-01-01
Some results from a numerical simulation of the formation of large-scale structure from cosmic-string loops are presented. It is found that even though G x mu is required to be lower than 2 x 10 to the -6th (where mu is the mass per unit length of the string) to give a low enough autocorrelation amplitude, there is excessive power on smaller scales, so that galaxies would be more dense than observed. The large-scale structure does not include a filamentary or connected appearance and shares with more conventional models based on Gaussian perturbations the lack of cluster-cluster correlation at the mean cluster separation scale as well as excessively small bulk velocities at these scales.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hipp, E; Osa, E; No, H
2014-06-01
Purpose: Challenges for radiation therapy in developing countries include unreliable infrastructure and high patient load. We propose a system to treat whole breast in the prone position without computed tomography and/or planning software. Methods: Six parameters are measured using calipers and levels with the patient prone in the treatment position. (1) The largest separation; (2) the angle that separation makes with the horizontal; (3) the separation 2 cm posterior to the nipple; (4) the vertical distance between these two separations; (5) the sup/inf length and (6) angle of the desired posterior field edge. The data in (5) (6) and (2)more » provide field length, collimator and gantry angles. Isocenter is set to the midpoint of (1), anterior jaw setting is 20cm (half-beam setup), and the dose is prescribed to a point 1.5 cm anterior to isocenter. MUs and wedge angles are calculated using an MU calculator and by requiring 100% dose at that point and 100-105% at the midpoint of (3). Measurements on 30 CT scans were taken to obtain the data 1-6. To test the resulting MU/wedge combinations, they were entered into Eclipse (Varian) and dose distributions were calculated. The MU/wedge combinations were recorded and tabulated. Results: Performing a dose volume histogram analysis, the contoured breast V95 was 90.5%, and the average V90 was 94.1%. The maximum dose never exceeded 114.5%, (average 108%). The lung V20 was <5% for 96.7%, and the heart V5 was <10% for 93.3% of our sample. Conclusion: A method to provide prone whole breast treatment without CT-planning was developed. The method provides reasonable coverage and normal tissue sparing. This approach is not recommended if imaging and planning capabilities are available; it was designed to specifically avoid the need for CT planning and should be reserved to clinics that need to avoid that step.« less
Surface composition of near-Earth Asteroid (4953) 1990 MU: Possible fragment of (6) Hebe
NASA Astrophysics Data System (ADS)
Kelley, Michael S.; Gaffey, Michael J.; Reddy, Vishnu; Sanchez, Juan A.
2014-05-01
Near-Earth asteroids (NEAs) are interesting as both a threat to the Earth and as the immediate parent bodies of most meteorites. We observed NEA (4953) 1990 MU using the NASA Infrared Telescope Facility (IRTF) and University of Hawaii (U.H.) telescopes on Mauna Kea to constrain its surface composition and origin. The surface composition of 1990 MU is similar to ordinary chondrites (H chondrites). The calculated olivine and pyroxene chemistry of 1990 MU (Fa13.5±1.3 and Fs12.7±1.4) are consistent with the olivine and pyroxene chemistry ranges for H chondrites (Fa15-21 and Fs13-19) (Dunn, T.L., McCoy, T.J., Sunshine, J.M., McSween, H.Y. [2010]. Icarus 208, 789-797), although the estimated Fa value is at the lower end of the H chondrite range. The olivine abundance ratio of 1990 MU (0.57 ± 0.03) is slightly higher but not inconsistent with H chondrites (0.47-0.55 ± 0.03). The radar circular polarization ratio (same circular polarization state or SC/opposite circular polarization state or OC) (Benner, L.A.M., Ostro, S.J., Magri, C., Nolan, M.C., Howell, E.S., Giorgini, J.D., Jurgens, R.F., Margot, J.L., Taylor, P.A., Busch, M.W., Shepard, M.K. [2008]. Icarus, 198, 294-304) of 1990 MU is 0.36 ± 0.03, which is higher than the mean SC/OC ratio for S-type NEAs (0.270 ± 0.079). The 1990 MU SC/OC is also higher than those of (25143) Itokawa (0.27 ± 0.04), (4179) Toutatis (0.29 ± 0.01) and (433) Eros (0.28 ± 0.06) suggesting a rougher surface at decimeter scale (Benner, L.A.M., Ostro, S.J., Magri, C., Nolan, M.C., Howell, E.S., Giorgini, J.D., Jurgens, R.F., Margot, J.L., Taylor, P.A., Busch, M.W., Shepard, M.K. [2008]. Icarus, 198, 294-304). We constrained the diameter of 1990 MU (4.4 km) using the average albedo at 0.55 μm of H chondrites (0.21) and absolute magnitude (H) of 14.1 (Flower, J.W., Chillemi J.R. [1992]. IRAS Asteroid Data Processing: The IRAS Minor Planet Survey, Philips Laboratory Technical Report PL-TR-92-2049. Jet Propulsion Laboratory, Pasadena, California, pp. 17-43). This diameter is higher than the 2.8 km value from Harris et al. (Harris, A.W. et al. [2011]. Astron. J. 141, 10) using an albedo of 0.52 for 1990 MU. This albedo value is unusually high for H chondrites, which have an albedo range of 0.12-0.30. We compared olivine and pyroxene chemistries of 1990 MU with main belt Asteroid (6) Hebe, probable parent body of H chondrite meteorites and IIE irons (Gaffey, M.J., Gilbert, S.L. [1998]. Meteor. Planet. Sci. 33, 1281-1295), and found that 1990 MU has more high-calcium pyroxene than Hebe. Fayalite and ferrosilite values of the two asteroids are consistent with H chondrites but do not overlap each other. The differences could be due to compositional variations observed on Hebe by Gaffey and Gilbert (Gaffey, M.J., Gilbert, S.L. [1998]. Meteor. Planet. Sci. 33, 1281-1295), although the observed rotational variation in spectral parameters does not match well with those of 1990 MU.
SU-F-T-266: Dynalogs Based Evaluation of Different Dose Rate IMRT Using DVH and Gamma Index
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ahmed, S; Ahmed, S; Ahmed, F
2016-06-15
Purpose: This work investigates the impact of low and high dose rate on IMRT through Dynalogs by evaluating Gamma Index and Dose Volume Histogram. Methods: The Eclipse™ treatment planning software was used to generate plans on prostate and head and neck sites. A range of dose rates 300 MU/min and 600 MU/min were applied to each plan in order to investigate their effect on the beam ON time, efficiency and accuracy. Each plan had distinct monitor units per fraction, delivery time, mean dose rate and leaf speed. The DVH data was used in the assessment of the conformity and planmore » quality.The treatments were delivered on Varian™ Clinac 2100C accelerator equipped with 120 leaf millennium MLC. Dynalogs of each plan were analyzed by MATLAB™ program. Fluence measurements were performed using the Sun Nuclear™ 2D diode array and results were assessed, based on Gamma analysis of dose fluence maps, beam delivery statistics and Dynalogs data. Results: Minor differences found by adjusted R-squared analysis of DVH’s for all the plans with different dose rates. It has been also found that more and larger fields have greater time reduction at high dose rate and there was a sharp decrease in number of control points observed in dynalog files by switching dose rate from 300 MU/min to 600 MU/min. Gamma Analysis of all plans passes the confidence limit of ≥95% with greater number of passing points in 300 MU/min dose rate plans. Conclusion: The dynalog files are compatible tool for software based IMRT QA. It can work perfectly parallel to measurement based QA setup and stand-by procedure for pre and post delivery of treatment plan.« less
A Search for Variation in the Surface Mineralogical Composition of J VI Himalia
NASA Astrophysics Data System (ADS)
Jarvis, K. S.; Vilas, F.; Larson, S. M.; Gaffey, M. J.
1996-09-01
Diverse spectral data exist for Jupiter's moon J VI Himalia. The overall spectral shape suggests that it has the same mineralogical composition as a C-class asteroid, lending credibility to the theory that Himalia was a C-class asteroid that formed in or near the main asteroid belt and was ejected and captured into orbit around Jupiter. Using an algorithm developed earlier, ECAS photometry (Tholen and Zellner, 1984) of Himalia taken on one date only have tested positively for the presence of a 0.7- mu m feature attributed to an Fe(2+) -> Fe(3+) charge transfer transition in oxidized iron in phyllosilicates. The presence of this feature was confirmed by narrowband spectrophotometry obtained on one date in April, 1995. Narrowband spectrophotometry of Luu (1991) does not cover the full spectral range defined by the 0.7-mu m absorption feature, but is in good agreement with the ECAS photometry. However, no 3.0-mu m water of hydration absorption feature was observed in IR radiometry (A. S., Rivkin, per. comm.). Correlation between the 0.7-mu m feature and the 3.0-mu m feature has been demonstrated in spectra of low-albedo asteroids, and suggests that it should be present. A rough rotational period for Himalia of 9.2 - 9.8 hrs is known. Himalia could represent the junction of two different compositional units, produced when an impact fragmented Himalia's parent body. The presence of iron-bearing phyllosilicates on part of Himalia's surface supports the hypothesis that Himalia is a captured C-class asteroid. Rotationally-resolved spectra of Himalia could confirm a variation in composition; we have started a program to collect these data.
Ackerman, Sara L; Sarkar, Urmimala; Tieu, Lina; Handley, Margaret A; Schillinger, Dean; Hahn, Kenneth; Hoskote, Mekhala; Gourley, Gato; Lyles, Courtney
2017-09-01
US health care institutions are implementing secure websites (patient portals) to achieve federal Meaningful Use (MU) certification. We sought to understand efforts to implement portals in "safety net" health care systems that provide services for low-income populations. Our rapid ethnography involved visits at 4 California safety net health systems and in-depth interviews at a fifth. Visits included interviews with clinicians and executives ( n = 12), informal focus groups with front-line staff ( n = 35), observations of patient portal sign-up procedures and clinic work, review of marketing materials and portal use data, and a brief survey ( n = 45). Our findings demonstrate that the health systems devoted considerable effort to enlisting staff support for portal adoption and integrating portal-related work into clinic routines. Although all health systems had achieved, or were close to achieving, MU benchmarks, patients faced numerous barriers to portal use and our participants were uncertain how to achieve and sustain "meaningful use" as defined by and for their patients. Health systems' efforts to achieve MU certification united clinic staff under a shared ethos of improved quality of care. However, MU's assumptions about patients' demand for electronic access to health information and ability to make use of it directed clinics' attention to enrollment and message routing rather than to the relevance and usability of a tool that is minimally adaptable to the safety net context. We found a mismatch between MU-based metrics of patient engagement and the priorities and needs of safety net patient populations. © The Author 2017. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com
a Search for Nucleon Decay with Multiple Muon Decays
NASA Astrophysics Data System (ADS)
Phillips, Thomas James
A search was made for nucleon decays which result in multiple delayed muon decays using the HPW (Harvard -Purdue-Wisconsin) water Cerenkov detector. The HPW detector consists of 680 metric tons of purified water instrumented with 704 five-inch photomultiplier tubes. The phototubes are situated on a volume array with a lattice spacing of approximately one meter, and the inside walls of the detector are lined with mirrors. This combination of mirrors and a volume array of phototubes gives the HPW detector a low trigger energy threshold and a high muon decay detection efficiency. The detector is surrounded by wire chambers to provide an active shield, and is located at a depth of 1500 meters-of-water-equivalent in the Silver King Mine in Park City, Utah. The entire HPW data set, consisting of 17.2 million events collec- ted during 282 live days between May 1983 and October 1984, was analyzed. No contained events with multiple muon decays were found in a 180 ton fiducial volume. This is consistent with the background rate from neutrino interactions, which is expected to be 0.7 (+OR-) 0.2 events. The calculated lower lifetime limit for the decay mode p (--->) (mu)('+)(mu)('+)(mu)('-) is: (tau)/B.R. = 1 x 10('31) years (90% C.L.). Limits are calculated for ten other proton decay modes and five bound neutron decay modes, most of which are around 4 x 10('30) years (90% C.L.). No previous studies have reported results from direct searches for eight of these modes.
Krüger, Nadine; Sauder, Christian; Hoffmann, Markus; Örvell, Claes; Drexler, Jan Felix; Rubin, Steven; Herrler, Georg
2016-11-01
A recent study reported the detection of a bat-derived virus (BatPV/Epo_spe/AR1/DCR/2009, batMuV) with phylogenetic relatedness to human mumps virus (hMuV). Since all efforts to isolate infectious batMuV have reportedly failed, we generated recombinant mumps viruses (rMuVs) in which the open reading frames (ORFs) of the fusion (F) and haemagglutinin-neuraminidase (HN) glycoproteins of an hMuV strain were replaced by the corresponding ORFs of batMuV. The batMuV F and HN proteins were successfully incorporated into viral particles and the resultant chimeric virus was able to mediate infection of Vero cells. Distinct differences were observed between the fusogenicity of rMuVs expressing one or both batMuV glycoproteins: viruses expressing batMuV F were highly fusogenic, regardless of the origin of HN. In contrast, rMuVs expressing human F and bat-derived HN proteins were less fusogenic compared to hMuV. The growth kinetics of chimeric MuVs expressing batMuV HN in combination with either hMuV or batMuV F were similar to that of the backbone virus, whereas a delay in virus replication was obtained for rMuVs harbouring batMuV F and hMuV HN. Replacement of the hMuV F and HN genes or the HN gene alone by the corresponding batMuV genes led to a slight reduction in neurovirulence of the highly neurovirulent backbone strain. Neutralizing antibodies inhibited infection mediated by all recombinant viruses generated. Furthermore, group IV anti-MuV antibodies inhibited the neuraminidase activity of bat-derived HN. Our study reports the successful generation of chimeric MuVs expressing the F and HN proteins of batMuV, providing a means for further examination of this novel batMuV.
STRONTIUM-90 IN HUMAN DIET IN NORTHERN AND SOUTHERN RHODESIA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carr, W.R.; Mercer, E.R.
1962-05-01
Sr/sup 90/ content in grain crops has frequently exceeded that in other foods; particular attention was, therefore, given to maize, which is the main source of calories in the African's diet. The other foods selected for this survey are commonly eaten by Africans and are relatively good sources of Ca:. the millet rapoko (Eleusine coracana), peanuts (Arachis hypogaea), and milk. The grain samples were taken shortly after the 1959 harvest and were therefore planted in late 1958 at the beginnirg of the rainy season and harvested in April-- June, 1959. Milk was sampled in October, 1959, a hot, dry monthmore » immediately preceding the rains; January 1960, in the middle of the rainy season and at the time of high milk production; April 1960, at the end of the rainy season; and August 1960, a cool month in the middle of the dry season. The two Sahara nuclear test explosions took place on 13th of February, 1960, and 1st of April, 1960. The Sr/sup 90/ and Sr/sup 90//Ca values, respectively, per kg dry wt were as follows: maize <3 mu mu c, <38 mu mu c/g; peanuts 9.79, 17.7; rapoko 44.3, 10.3; milk 5.9-- 14.0, 0.56-1.34. It is estimated that the average monthly dietary intake of Sr/sup 90/ of the urban African population is <57 mu mu c. Because of the low Sr/sup 90/ content per kg of maize, more precise determinations were impossible; the figure quoted is the upper limit only. A comparison of the results for two samples of peanuts suggests that contamination was highest in the areas of high rainfall. Only a small variation with rainfall was observed with rapoko, which was by far the most irriportant source of contamination. With milk, appreciably higher values were found in the Spring of both years (October 1959, and August 1960). The markedly lower ratios of Sr/sup 90/ to Ca in milk than in vegetable foods reflect the discrimination which occurs against Sr relative to Ca in their passage from the diet of cattle to milk. Although the content of milk was under 10% of that observed in the United Kingdom in 1959, the estimated ratio of Sr/sup 90/ to Ca in the diet for the population of the urban areas differs little. It was concluded that on average the content of diet was less than 1/20 of the recommended max permissible level and that it did not reach 1/10 for any large section of the African population. It appears that the contamination of the diet of Europeans in Rhodesia was considerably lower than that in the United Kingdom. (H.H.D.)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glasgow, G.P.; Corrigan, K.W.
We have renovated, and used for four years, a small 3.4 m x 4.3 m conventional patient second floor hospital room to accommodate a low dose rate remote afterloading unit containing 13 GBq (0.35 Ci) of {sup 137}Cs. Supplemental room shielding consists of a power assisted door (536 kg, 1.7 cm thickness of lead), 1.3 cm lead wall shielding at selected wall locations and on a projector shield beneath the bed, and 0.6 cm of lead over the floor above. Radiation control features consisted of a room interior radiation detector independent of the remote afterloading unit, a redundant patient/nurse communicationmore » system, a remote control system, a door interlock system to insert and retract the radioactive pellets, and a visible and audible status indictator system located at a nearby nurses` work station. Renovation costs (in 1990 dollars) were $383 per square foot; total project costs were $187,000. Nursing personnel radiation exposure was reduced from about 6 {mu}Sv (mg Ra eq){sup -1} (0.6 mrem (mg Ra eq){sup -1}) to about 0.7 {mu}Sv (mg Ra eq){sup -1} (0.07 mrem (mg Ra eq){sup -1}), almost a tenfold reduction. 6 refs., 2 figs., 1 tab.« less
Kato, Merii; Tanase, Tomoaki; Mikuriya, Masahiro
2006-04-03
Reactions of CuX2.nH2O with the biscarboxylate ligand XDK (H2XDK = m-xylenediamine bis(Kemp's triacid imide)) in the presence of N-donor auxiliary ligands yielded a series of dicopper(II) complexes, [Cu2(mu-OH)(XDK)(L)2]X (L = N,N,N',N'-tetramethylethylenediamine (tetmen), X = NO3 (1a), Cl (1b); L = N,N,N'-trimethylethylenediamine (tmen), X = NO3 (2a), Cl (2b); L =2,2'-bipyridine (bpy), X = NO3 (3); L = 1,10-phenanthroline (phen), X = NO3 (4); L = 4,4'-dimethyl-2,2'-bipyridine (Me2bpy), X = NO3 (5); L = 4-methyl-1,10-phenanthroline (Mephen), X = NO3 (6)). Complexes 1-6 were characterized by X-ray crystallography (Cu...Cu = 3.1624(6)-3.2910(4) A), and the electrochemical and magnetic properties were also examined. Complexes 3 and 4 readily reacted with diphenyl phosphoric acid (HDPP) or bis(4-nitrophenyl) phosphoric acid (HBNPP) to give [Cu2(mu-phosphate)(XDK)(L)2]NO3 (L = bpy, phosphate = DPP (11); L = phen, phosphate = DPP (12), BNPP (13)), where the phsophate diester bridges the two copper ions in a mu-1,3-O,O' bidentate fashion (Cu...Cu = 4.268(3)-4.315(1) A). Complexes 4 and 6 with phen and Mephen have proven to be good precursors to accommodate a series of sugar monophosphate esters (Sugar-P) onto the biscarboxylate-bridged dicopper centers, yielding [Cu2(mu-Sugar-P)(XDK)(L)2] (Sugar-P = alpha-D-Glc-1-P (23a and b), D-Glc-6-P (24a and b), D-Man-6-P (25a), D-Fru-6-P (26a and b); L = phen (a), Mephen (b)) and [Cu2(mu-Gly-n-P)(XDK)(Mephen)2] (Gly-n-P = glycerol n-phosphate; n = 2 (21), 3 (22)), where Glc, Man, and Fru are glucose, mannose, and fructose, respectively. The structure of [Cu2(mu-MNPP)(XDK)(phen)2(CH3OH)] (20) was characterized as a reference compound (H2MNPP = 4-nitrophenyl phosphoric acid). Complexes 4 and 6 also reacted with d-fructose 1,6-bisphosphate (D-Fru-1,6-P2) to afford the tetranuclear copper(II) complexes formulated as [Cu4(mu-D-Fru-1,6-P2)(XDK)2(L)4] (L = phen (27a), Mephen (27b)). The detailed structure of 27a was determined by X-ray crystallography to involve two different tetranuclear complexes with alpha- and beta-anomers of D-Fru-1,6-P2, [Cu4(mu-alpha-D-Fru-1,6-P2)(XDK)2(phen)4] and [Cu4(mu-beta-D-Fru-1,6-P2)(XDK)2(phen)4], in which the D-Fru-1,6-P2 tetravalent anion bridges the two [Cu2(XDK)(phen)2]2+ units through the C1 and C6 phosphate groups in a mu-1,3-O,O' bidentate fashion (Cu...Cu = 4.042(2)-4.100(2) A). Notably, the structure with alpha-D-Fru-1,6-P2 demonstrated the presence of a strong hydrogen bond between the C2 hydroxyl group and the C1 phosphate oxygen atom, which may support the previously proposed catalytic mechanism in the active site of fructose-1,6-bisphosphatase.
Meaningful Use of School Health Data
ERIC Educational Resources Information Center
Johnson, Kathleen Hoy; Bergren, Martha Dewey
2011-01-01
Meaningful use (MU) of Electronic Health Records (EHRs) is an important development in the safety and security of health care delivery in the United States. Advancement in the use of EHRs occurred with the passage of the American Recovery and Reinvestment Act of 2009, which provides incentives for providers to support adoption and use of EHRs.…
Procura de Sinais de Dimensões Extras Universais em Colisões Próton-Antipróton (in Portuguese)
DOE Office of Scientific and Technical Information (OSTI.GOV)
de Souza Santos, Angelo
Models that predict the existence of extra spatial dimensions have been studied since the beginning of the 20th century. These models can incorporate gravity in the framework that describes the other interactions and they can present a number of interesting features such as a dark matter candidate. In this work, we explore the consequences of the Universal Extra Dimensions (UED) model by searching for the production of Kaluza-Klein particles whose decay chain leads to signaturemore » $$\\mu^{\\pm}\\mu^{\\pm} + \\mathrm{jets} + \\met$$. We employ the data set corresponding to an integrated luminosity of \\unit{7.3}{\\femto\\barn}$$^{-1}$$, collected by the \\dzero{} detector at a $$p\\bar p$$ collider at a center of mass energy of \\unit{1.96}{\\tera\\electronvolt}. Since no excess was observed in the data, we were able to set a lower limit on the compactification scale of $$R^{-1}>260$$ GeV in the model. This is the first study to impose a direct limit on the minimal UED model.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walton, B.T.
The toxicity of acridine to Acheta domesticus (L.) was determined to evaluate the potential for this pollutant from synthetic fuels production to affect insect populations. Acridine was highly toxic to cricket eggs but not toxic to nymphs or adults. An LD/sub 50/ for eggs = 7.4 ..mu..g/g was calculated from the LC/sub 50/ = 15.1 +- 0.61 ppM. The 24-h LD/sub 10/ of acridine to nymphal crickets was > 332 ..mu..g/g. Male and female crickets consumed up to 1.0% of their weight in acridine over an 18-day period with no significant effect on mortality, weight gain, digestibility of food, ormore » fecundity. Percent hatch of eggs from treated crickets (81.0 +- 6.7) was not significantly different from controls (77.2 +- 5.1).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walton, B.T.
The toxicity of acridine to Acheta domesticus (L.) was determined to evaluate the potential for this pollutant from synthetic fuels production to affect insect populations. Acridine was highly toxic to cricket eggs but not toxic to nymphs or adults. An LD/sub 50/ for eggs = 7.4 ..mu..g/g was calculated from the LC/sub 50/ = 15.1 +- 0.61 ppM. The 24-h LD/sub 10/ of acridine to nymphal crickets was >332 ..mu..g/g. Male and female crickets consumed up to 1.0% of their weight in acridine over an 18-day period with no significant effect on mortality, weight gain, digestibility of food, or fecundity.more » Percent hatch of eggs from treated crickets (81.0 +- 6.7) was not significantly different from controls (77.2 +- 5.1).« less
Preliminary test results from a telescope of Hughes pixel arrays at FNAL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jernigan, J.G.; Arens, J.; Vezie, D.
1992-09-01
In December of 1991 three silicon hybrid pixel detectors each having 2.56 [times] 2.56 pixels 30 [mu]m square, made by the Hughes Aircraft Company, were placed in a high energy muon beam at the Fermi National Accelerator Laboratory. Straight tracks were recorded in these detectors at angles to the normal to the plane of the silicon ranging from 0 to 45[degrees]. In this note, preliminary results are presented on the straight through tracks, i.e., those passing through the telescope at normal incidence. Pulse height data, signal-to-noise data, and preliminary straight line fits to the data resulting in residual distributions aremore » presented. Preliminary calculations show spatial resolution of less than 5 [mu]m in two dimensions.« less
Preliminary test results from a telescope of Hughes pixel arrays at FNAL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jernigan, J.G.; Arens, J.; Vezie, D.
1992-09-01
In December of 1991 three silicon hybrid pixel detectors each having 2.56 {times} 2.56 pixels 30 {mu}m square, made by the Hughes Aircraft Company, were placed in a high energy muon beam at the Fermi National Accelerator Laboratory. Straight tracks were recorded in these detectors at angles to the normal to the plane of the silicon ranging from 0 to 45{degrees}. In this note, preliminary results are presented on the straight through tracks, i.e., those passing through the telescope at normal incidence. Pulse height data, signal-to-noise data, and preliminary straight line fits to the data resulting in residual distributions aremore » presented. Preliminary calculations show spatial resolution of less than 5 {mu}m in two dimensions.« less
ACE: Automatic Centroid Extractor for real time target tracking
NASA Technical Reports Server (NTRS)
Cameron, K.; Whitaker, S.; Canaris, J.
1990-01-01
A high performance video image processor has been implemented which is capable of grouping contiguous pixels from a raster scan image into groups and then calculating centroid information for each object in a frame. The algorithm employed to group pixels is very efficient and is guaranteed to work properly for all convex shapes as well as most concave shapes. Processing speeds are adequate for real time processing of video images having a pixel rate of up to 20 million pixels per second. Pixels may be up to 8 bits wide. The processor is designed to interface directly to a transputer serial link communications channel with no additional hardware. The full custom VLSI processor was implemented in a 1.6 mu m CMOS process and measures 7200 mu m on a side.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mack, Philipp; /Karlsruhe U., EKP
We report on the search for B{sup 0}{sub s}{yields}{mu}{sup +}{mu}{sup -}, B{sup 0}{sub d}{yields}{mu}{sup +}{mu}{sup -} decays and b{yields} s{mu}{sup +}{mu}{sup -} transitions in exclusive decays of B mesons using the CDF II detector at the Fermilab Tevatron Collider. Using 2 fb{sup -1} of Run II data we find upper limits on the branching fractions {beta}(B{sup 0}{sub s}{yields}{mu}{sup +}{mu}{sup -})<5.8 x 10{sup -8} and {beta}(B{sup 0}{sub d}{yields}{mu}{sup +}{mu}{sup -})<1.8 x 10{sup -8} at 95% confidence level. The results for the branching fractions of the b{yields} s{mu}{sup +}{mu}{sup -} transitions using 924 pb{sup -1} of Run II data are {beta}(B{sup +}{yields}{mu}{supmore » +}{mu}{sup -}K{sup +})=(0.60{+-}0.15{+-}0.04) x 10{sup -6}, {beta}(B{sup 0}{sub d}{yields}{mu}{sup +}{mu}{sup -}K{sup *0})=(0.82{+-}0.31{+-}0.10) x 10{sup -6} and {beta}(B{sup 0}{sub s}{yields} {mu}{sup +}{mu}{sup -}{phi})/{beta}(B{sup 0}{sub s}{yields}J/{psi}{phi}) < 2.61 x 10{sup -3} at 95% confidence level.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Svendsen, Helle; Jørgensen, Mads Ry Vogel; Overgaard, Jacob
2012-10-11
Single crystal synchrotron X-ray diffraction measurements have been carried out on [Nd(DMF){sub 4}(H{sub 2}O){sub 3}({mu}-CN)Fe(CN){sub 5}] {center_dot} H{sub 2}O (DMF = dimethyl-formamide), 1; [Y(DMF){sub 4}(H{sub 2}O){sub 3}({mu}-CN)Fe(CN){sub 5}] {center_dot} H{sub 2}O, 2; [Ce(DMF){sub 4}(H{sub 2}O){sub 3}({mu}-CN)Fe(CN){sub 5}] {center_dot} H{sub 2}O, 3; [Sm(DMF){sub 4}(H{sub 2}O){sub 3}({mu}-CN)Fe(CN){sub 5}] {center_dot} H{sub 2}O, 4; [Tb(DMF){sub 4}(H{sub 2}O)3({mu}-CN)Fe(CN){sub 5}] {center_dot} H{sub 2}O, 5; [Yb(DMF){sub 4}(H{sub 2}O){sub 3}({mu}-CN)Fe(CN){sub 5}] {center_dot} H{sub 2}O, 6; and [Nd(DMF){sub 4}(H{sub 2}O){sub 3}({mu}-CN)Co(CN){sub 5}] {center_dot} H{sub 2}O, 7, at 15(2) K with and without UV illumination of the crystals. Significant changes in unit cell parameters are observed for all of themore » iron-containing complexes, while compound 7 shows no response to UV illumination. These results are consistent with previous results and are furthermore reproduced by powder synchrotron X-ray diffraction for compounds 1 and 7. Photoexcited crystal structures have been determined for 1-6 from refinements of two-conformer models, and excited state occupancies in the range 80-94% are found. Significant bond length changes are observed for the Fe-ligand bonds (up to 0.06 {angstrom}), the cyano bonds (up to 0.02 {angstrom}), and the lanthanide-ligand bonds (up to 0.1 {angstrom}). On the contrary, powder X-ray diffraction on the simple compound K{sub 3}Fe(CN)6, 8, upon UV illumination does not show any structural changes, suggesting that the photomagnetic effect requires the presence of both the transition metal and the lanthanide ion. Photomagnetic measurements show an increase in magnetization of the excited state of 1 of up to 3%, which is much diminished compared with previously published values of 45%. Furthermore, they show that the isostructural complex [La(DMF){sub 4}(H{sub 2}O){sub 3}({mu}-CN)Fe(CN){sub 5}] {center_dot} H{sub 2}O, 9, exhibits identical magnetic responses in the UV-induced excited crystal structure.« less
Spreadsheet Simulation of the Law of Large Numbers
ERIC Educational Resources Information Center
Boger, George
2005-01-01
If larger and larger samples are successively drawn from a population and a running average calculated after each sample has been drawn, the sequence of averages will converge to the mean, [mu], of the population. This remarkable fact, known as the law of large numbers, holds true if samples are drawn from a population of discrete or continuous…
Slipping and Rolling on an Inclined Plane
ERIC Educational Resources Information Center
Aghamohammadi, Cina; Aghamohammadi, Amir
2011-01-01
In the first part of the paper, using a direct calculation two-dimensional motion of a particle sliding on an inclined plane is investigated for general values of friction coefficient ([mu]). A parametric equation for the trajectory of the particle is also obtained. In the second part of the paper, the motion of a sphere on the inclined plane is…
Muon pair production at 52 GeV le radical s le 57 GeV using the AMY Detector at TRISTAN
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bacala, A.M.
1989-01-01
The reaction e{sup +}e{sup {minus}} {yields} {mu}{sup +}{mu}{sup {minus}} has been observed by the AMY Detector at 52 GeV {le} {radical}s {le} 57 GeV at the TRISTAN storage ring in Tsukuba, Japan. With an integrated luminosity of 18.6 pb{sup {minus}1}, this presents a new test of the standard model of the electroweak interactions in this previously unexplored energy region. The forward-backward charge asymmetry and the cross-section calculated at the various energies show agreement with the standard model predictions. The products of the vector and the axial-vector coupling constants of the electron and muon extracted from these measurements are also consistentmore » with theory. The data were combined at the average energy of {radical}s = 55.2 GeV. The measured asymmetry and cross-section are -34.4 {+-} 7.7% and 29.7 {+-} 2.1 pb respectively. This is in agreement with the standard model prediction of -28.3% for the asymmetry and 29.5 pb for the cross-section. The product of the axial couplings, g{sup e}{sub A}g{sup {mu}}{sub A} = 0.29 {+-} 0.07, and the product of the vector couplings, g{sup e}{sub V}g{sup {mu}}{sub V} = 0.01 {+-} 0.06, agree with the standard model predictions of 0.25 and .002 for these respective constants.« less
Moduli space potentials for heterotic non-Abelian flux tubes: Weak deformation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shifman, M.; Yung, A.; Petersburg Nuclear Physics Institute, Gatchina, St. Petersburg 188300
2010-09-15
We consider N=2 supersymmetric QCD with the U(N) gauge group (with no Fayet-Iliopoulos term) and N{sub f} flavors of massive quarks deformed by the mass term {mu} for the adjoint matter, W={mu}A{sup 2}, assuming that N{<=}N{sub f}<2N. This deformation breaks N=2 supersymmetry down to N=1. This theory supports non-Abelian flux tubes (strings) which are stabilized by W. They are referred to as F-term stabilized strings. We focus on the studies of such strings in the vacuum in which N squarks condense, at small {mu}, so that the Z{sub N} strings preserve, in a sense, their Bogomol'nyi-Prasad-Sommerfield nature. The (s)quark massesmore » are assumed to be nondegenerate. We calculate string tensions both in the classical and quantum regimes. Then we translate our results for the tensions in terms of the effective low-energy weighted CP(N{sub f}-1) model on the string world sheet. The bulk {mu} deformation makes this theory N=(0,2) supersymmetric heterotic weighted CP(N{sub f}-1) model in two dimensions. We find the deformation potential on the world sheet. This significantly expands the class of the heterotically deformed CP models emerging on the string world sheet compared to that suggested by Edalati and Tong. Among other things, we show that nonperturbative quantum effects in the bulk theory are exactly reproduced by the quantum effects in the world-sheet theory.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Young, M.S.
1996-11-01
Atrazine and related triazine herbicides are used in great quantities throughout the world for pre-emergence weed control. In the central United States, for example, millions of kilograms of triazines are applied each year. In areas of heavy usage, surface water supplies are often affected by runoff of these substances and their transformation products. Therefore, a number of these compounds are routinely monitored in drinking water in the United States, particularly in agricultural areas such as the Mississippi river valley. There is also significant interest regarding the fate and transport of the triazine herbicides in the natural environment. In Europe, wheremore » groundwater is utilized for a high proportion of drinking water supplies, the EC has established more stringent limits than has the US EPA. Currently, the US limit is 3 {mu}g/L for atrazine; the European limit is 0.1 {mu}g/L for atrazine or any individual regulated pesticide, and 0.5 {mu}g/L for the sum of all pesticides. Because groundwater levels in agricultural areas were consistently above this limit, Germany banned the use of Atrazine in 1991, and has recommended banning the use of this herbicide throughout the European Community (EC). Clearly, a rugged method for determination of the triazine herbicides is desirable with detection limits in the part per trillion range. Because direct determination at these levels is not usually possible, sample enrichment techniques, such as solid phase extraction (SPE), must be employed. In this study, Porapak RDX Sep-Pak{reg_sign} cartridges were used for trace enrichment of triazines and metabolites.« less
Intruder Dynamic Response in Particulate Media
NASA Astrophysics Data System (ADS)
Warnakulasooriya, Niranjan
Many everyday materials, broadly classified as "particulate media", are at the heart of many industries and natural phenomena. Examples range from the storage and transport of bulk foods and aggregates such as grains and coal; the processing of pharmaceutical pills and the grinding coffee beans; to the mitigation and cost control of life-threatening events like landslides, earthquakes, and silo failures. The common theme connecting all these phenomena is the mechanical stability of the granular material that arises from interactions at the microscopic level of the grain scale, and how this influences collective properties at the bulk, macroscopic scale. In this dissertation, we present an extensive study of the mechanical properties of a physics-based model of granular particle systems in two dimensions using computer simulations. Specifically, we study the dynamics of an intruder particle that is driven through a dense, disordered packing of particles. This practical technique has the benefit of being amenable to experimental application which we expect will motivate future studies in the area. We find the 'microrheology' of the intruder can be traced back to the properties of underlying, original, unperturbed packing, thereby providing a method to characterize the mechanical properties of the material that may otherwise be unavailable. To perform this study, we initially created mechanically stable granular packings of bidisperse discs, for several orders of magnitude of particle friction coefficient mu, over a range in packing densities, or packing fractions φ, in the vicinity of the critical packing fraction φc, the density below which the packing is no longer stable. This range in φ translates to a range in packing pressures P, spanning several orders of magnitude down to the P → 0 limit. For each packing, we apply a driving force to the intruder probe particle and find the critical force Fc, the minimum force required to induce motion of the probe as it is dragged through the system. We find that Fc(mu) for the different friction packings, scales with the packing pressure P as a power-law according to:Fc(mu) - Fo cmu) Pbeta(mu). The power-law exponent, beta(mu) becomes friction dependent, but approaches the value, beta(mu → 0) = 1.0 +/- 0.1 in the zero-friction limit. Focmu) is the value of F c in the limit P → 0, that similarly depends on the friction coefficient as, Focmu) → 0, when mu → infinity. We use this property of Fo cmu) to characterize the mechanical properties of different frictional packings. Another focus of this study is the 'microrheology' of the intruder through force-velocity dependencies in mu = 0 systems at different P. For this case, the intruder is driven through the packing at a steady-state velocity , for driving forces above the critical force FD > Fc. We introduce a scaling function that collapses the force-velocity curves onto a single master curve. This power law scaling of the collapsed curve as P → 0 is reminiscent of a continuous phase transition, reinforcing the notion that the mechanical state of the system exhibits critical-like features. Furthermore, we also find an alternative scaling collapse of the form: - (FD - Fc) alpha, where represents a constant velocity term in the limit of small excess forcing, and the critical force Fc now appears as fitting parameter that matches our explicit calculations. Thence, we are able to extract Fc from a driven probe without a-priori having any knowledge about the state of the system. To further investigate the transition of the system through the different intruder force perturbations, we implemented a coarse graining (CG) technique that transforms our discrete particle interaction force information into continuous stress fields. Through this methodology, we are able to calculate the kinetic and contact stresses as the intruder is driven through the system. We are able to qualify and quantify the directional and distance dependencies of the stress response of the packing due to the driven probe via radial and azimuthal stress calculations. In particular, we find how the stress response not only captures the wake region behind the driven intruder, but also how the stress decays in the forward direction of the intruder, which follows universal behavior.
Unsteady Spherical Diffusion Flames in Microgravity
NASA Technical Reports Server (NTRS)
Atreya, Arvind; Berhan, S.; Chernovsky, M.; Sacksteder, Kurt R.
2001-01-01
The absence of buoyancy-induced flows in microgravity (mu-g) and the resulting increase in the reactant residence time significantly alters the fundamentals of many combustion processes. Substantial differences between normal gravity (ng) and (mu-g) flames have been reported in experiments on candle flames, flame spread over solids, droplet combustion, and others. These differences are more basic than just in the visible flame shape. Longer residence times and higher concentration of combustion products in the flame zone create a thermochemical environment that changes the flame chemistry and the heat and mass transfer processes. Processes such as flame radiation, that are often ignored in ng, become very important and sometimes even controlling. Furthermore, microgravity conditions considerably enhance flame radiation by: (i) the build-up of combustion products in the high-temperature reaction zone which increases the gas radiation, and (ii) longer residence times make conditions appropriate for substantial amounts of soot to form which is also responsible for radiative heat loss. Thus, it is anticipated that radiative heat loss may eventually extinguish the "weak" (low burning rate per unit flame area) mu-g diffusion flame. Yet, space shuttle experiments on candle flames show that in an infinite ambient atmosphere, the hemispherical candle flame in mu-g will burn indefinitely. This may be because of the coupling between the fuel production rate and the flame via the heat-feedback mechanism for candle flames, flames over solids and fuel droplet flames. Thus, to focus only on the gas-phase phenomena leading to radiative extinction, aerodynamically stabilized gaseous diffusion flames are examined. This enables independent control of the fuel flow rate to help identify conditions under which radiative extinction occurs. Also, spherical geometry is chosen for the mu-g experiments and modeling because: (i) It reduces the complexity by making the problem one-dimensional; (ii) The spherical diffusion flame completely encloses the soot which is formed on the fuel rich side of the reaction zone. This increases the importance of flame radiation because now both soot and gaseous combustion products co-exist inside the high temperature spherical diffusion flame. (iii) For small fuel injection velocities, as is usually the case for a pyrolyzing solid, the diffusion flame in mu-g around the solid naturally develops spherical symmetry. Thus, spherical diffusion flames are of interest to fires in mu-g and identifying conditions that lead to radiation-induced extinction is important for spacecraft fire safety.
Exact, E = 0, classical and quantum solutions for general power-law oscillators
NASA Technical Reports Server (NTRS)
Nieto, Michael Martin; Daboul, Jamil
1995-01-01
For zero energy, E = 0, we derive exact, classical and quantum solutions for all power-law oscillators with potentials V(r) = -gamma/r(exp nu), gamma greater than 0 and -infinity less than nu less than infinity. When the angular momentum is non-zero, these solutions lead to the classical orbits (p(t) = (cos mu(phi(t) - phi(sub 0)t))(exp 1/mu) with mu = nu/2 - 1 does not equal 0. For nu greater than 2, the orbits are bound and go through the origin. We calculate the periods and precessions of these bound orbits, and graph a number of specific examples. The unbound orbits are also discussed in detail. Quantum mechanically, this system is also exactly solvable. We find that when nu is greater than 2 the solutions are normalizable (bound), as in the classical case. Further, there are normalizable discrete, yet unbound, states. They correspond to unbound classical particles which reach infinity in a finite time. Finally, the number of space dimensions of the system can determine whether or not an E = 0 state is bound. These and other interesting comparisons to the classical system will be discussed.
Absorptivity of semiconductors used in the production of solar cell panels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kosyachenko, L. A., E-mail: lakos@chv.ukrpack.net; Grushko, E. V.; Mikityuk, T. I.
The dependence of the absorptivity of semiconductors on the thickness of the absorbing layer is studied for crystalline silicon (c-Si), amorphous silicon (a-Si), cadmium telluride (CdTe), copper indium diselenide (CuInSe{sub 2}, CIS), and copper gallium diselenide (CuGaSe{sub 2}, CGS). The calculations are performed with consideration for the spectral distribution of AM1.5 standard solar radiation and the absorption coefficients of the materials. It is shown that, in the region of wavelengths {lambda} = {lambda}{sub g} = hc/E{sub g}, almost total absorption of the photons in AM1.5 solar radiation is attained in c-Si at the thickness d = 7-8 mm, in a-Simore » at d = 30-60 {mu}m, in CdTe at d = 20-30 {mu}m, and in CIS and CGS at d = 3-4 {mu}m. The results differ from previously reported data for these materials (especially for c-Si). In previous publications, the thickness needed for the semiconductor to absorb solar radiation completely was identified with the effective light penetration depth at a certain wavelength in the region of fundamental absorption for the semiconductor.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huebert, D.B.
1992-01-01
The duckweed Lemna trisulca L. was grown in axenic cultures in a filter-sterilized medium. A portion of the medium was replaced regularly during experiments. The amount replaced doubled every two days. metal concentrations in the medium wee measured on the last day of experiments. The only organic compound added was FeEDTA at a concentration of 9 [mu]M. The chelating capacity of the medium was therefore minimal, defined and controlled. The nutrient medium and environmental conditions supported a doubling time of 1.6 to 2.4 days over a 14 day culture period. Under the above conditions, the EC50 (concentration at which amore » 50% effect is observed) for Cd and 0.99 [mu]M based on multiplication rate and 0.56 [mu]M based on final yield. The NOEC (no observable effect concentration) for Cd was between 120 and 150 [mu]g Cd/g dry wt. based on internal Cd, and 0.08 [mu]M based on external Cd. Internal Cd may be a superior estimate of toxicity because it avoids the problems associated with metal speciation in the external medium and allows for a comparison with field data. Lemna trisulca responded within 2 days to the addition of 0.64 [mu]M Cd. No tolerance to Cd was induced even after 6 weeks of exposure. The calculated response of L. trisulca to Cd may have been influenced by the multiplication rate of control cultures, which varied from 1.6 to 2.4 days. Calcium had no effect on Cd uptake or toxicity. Zinc antagonized Cd toxicity but had a variable effect on Cd uptake depending on its concentration. Zinc was about fifteen times less toxic than Cd. The uptake and toxicity of Cd and Zn were almost completely prevented when the level of available EDTA was in excess of the CD or Zn concentration. These data indicate that biological and chemical factors can profoundly influence the effect of toxicants on living organisms. These factors must be considered to ensure that toxicity studies are not confounded by effects extraneous to the actual effect of the toxicant.« less
Evaluation of ionic contribution to the toxicity of a coal-mine effluent using Ceriodaphnia dubia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kennedy, A.J.; Cherry, D.S.; Zipper, C.E.
2005-08-01
The United States Environmental Protection Agency has defined national in-stream water-quality criteria (WQC) for 157 pollutants. No WQC to protect aquatic life exist for total dissolved solids (TDS). Some water-treatment processes (e.g., pH modifications) discharge wastewaters of potentially adverse TDS into freshwater systems. Strong correlations between specific conductivity, a TDS surrogate, and several biotic indices in a previous study suggested that TDS caused by a coal-mine effluent was the primary stressor. Further acute and chronic testing in the current study with Ceriodaphnia dubia in laboratory-manipulated media indicated that the majority of the effluent toxicity could be attributed to the mostmore » abundant ions in the discharge, sodium (1952 mg/L) and/or sulfate (3672 mg/L), although the hardness of the effluent (792 43 mg/L as CaCO{sub 3}) ameliorated some toxicity. Based on laboratory testing of several effluent-mimicking media, sodium- and sulfate-dominated TDS was acutely toxic at approximately 7000 {mu} S/cm (5143 mg TDS/L), and chronic toxicity occurred at approximately 3200 {mu} S/cm (2331 mg TDS/L). At a lower hardness (88 mg/L as CaCO{sub 3}), acute and chronic toxicity end-points were decreased to approximately 5000 {mu} S/cm (3663 mg TDS/L) and approximately 2000 {mu} S/cm (1443 mg TDS/L), respectively. Point-source discharges causing in-stream TDS concentrations to exceed these levels may risk impairment to aquatic life.« less
The Composition of the Iapetus Dark Material, Hyperion and Phoebe
NASA Astrophysics Data System (ADS)
Stockstill, K. R.; Larson, S. M.; Vilas, F.; Gaffey, M. J.
1996-09-01
A linear mixing model has been used to separate the high-resolution visible/near-infrared reflectance spectrum of the Iapetus dark material from spectra of the leading and trailing sides of Iapetus. A distinct absorption feature centered at 0.67 mu m is apparent in the spectrum. A slight inflection covering 0.4 to 0.6 mu m and a change in slope near 0.73 mu m suggesting the lower wavelength edge of an absorption are also present. These absorption features are attributed to (6) A1 -> (4) T2(G) and (6) A1 -> (4) T1(G) charge transfer transitions in minerals such as goethite and hematite that are products of the aqueous alteration of anhydrous silicates. We confirm the strong, positive spectral slope attributed to organic material. Broadband photometry of Phoebe using ECAS filters was acquired on four nights in 1982 (Tholen and Zellner, Icarus, 1983). On two nights covering the same side of Phoebe, the photometry tested positively for an absorption feature centered at 0.7 mu m due to oxidized iron in phyllosilicates. The opposite side of Phoebe was covered by the other two observations. The spectral difference between two opposite sides of Phoebe suggests that an impact fragmented Phoebe's parent body, producing Phoebe at the junction of two different compositional units. High resolution reflectance spectra have been obtained of the Saturnian satellites Phoebe and Hyperion, the main candidates for a circumsaturnian origin of the Iapetus dark material. These will be discussed.
Cañadillas-Delgado, Laura; Fabelo, Oscar; Pásan, Jorge; Delgado, Fernando S; Lloret, Francesc; Julve, Miguel; Ruiz-Pérez, Catalina
2007-09-03
The first coordination compounds of 1,2,3,4-butanetetracarboxylate anion (butca4-) of the formula [M2(butca)(H2O)5]n.2nH2O [M=Mn(II) (1), Co(II) (2), and Ni(II) (3)] were prepared and their X-ray crystal structures and magnetic properties investigated. The three complexes have a very similar two-dimensional structure which consists of (4,4) networks, 1 and 2 being isostructural. The tetracarboxylate ligand acts as a 4-fold connector leading to two-dimensional (4,4) networks of metal atoms, this topology being possible because of its planar conformation. The nodes of these networks are formed by dinuclear motifs which exhibit the unusual (mu-aqua)bis(mu-carboxylate) bridging unit which is analogous to that observed in some molecules of biological interest. The variable-temperature magnetic susceptibility measurements of 1-3 show that 1 and 2 are antiferromagnetically coupled systems whereas 3 exhibits a ferromagnetic behavior. The analysis of the magnetic data of 1-3 through a simple dinuclear model allowed the determination of the values of the magnetic coupling (J) -3.6 (1), -1.2 (2), and +1.47 cm(-1) (3) with the Hamiltonian being defined as H=-JSA.SB. The countercomplementarity between the two bridges (aqua and syn-syn carboxylate) accounts for the trend exhibited by the values of the magnetic coupling in this family.
Schnitzler, P; Delius, H; Scholz, J; Touray, M; Orth, E; Darai, G
1987-12-01
The genome of the fish lymphocystis disease virus (FLDV) was screened for the existence of repetitive DNA sequences using a defined and complete gene library of the viral genome (98 kbp) by DNA-DNA hybridization, heteroduplex analysis, and restriction fine mapping. A repetitive DNA sequence was detected at the coordinates 0.034 to 0.057 and 0.718 to 0.736 map units (m.u.) of the FLDV genome. The first region (0.034 to 0.057 m.u.) corresponds to the 5' terminus of the EcoRI FLDV DNA fragment B (0.034 to 0.165 m.u.) and the second region (0.718 to 0.736 m.u.) is identical to the EcoRI DNA fragment M of the viral genome. The DNA nucleotide sequence of the EcoRI FLDV DNA fragment M was determined. This analysis revealed the presence of many short direct and inverted repetitions, e.g., a 18-mer direct repetition (TTTAAAATTTAATTAA) that started at nucleotide positions 812 and 942 and a 14-mer inverted repeat (TTAAATTTAAATTT) at nucleotide positions 820 and 959. Only short open reading frames were detected within this region. The DNA repetitions are discussed as sequences that play a possible regulatory role for virus replication. Furthermore, hybridization experiments revealed that the repetitive DNA sequences are conserved in the genome of different strains of fish lymphocystis disease virus isolated from two species of Pleuronectidae (flounder and dab).
Suitability of rapid energy magnitude determinations for emergency response purposes
NASA Astrophysics Data System (ADS)
Di Giacomo, Domenico; Parolai, Stefano; Bormann, Peter; Grosser, Helmut; Saul, Joachim; Wang, Rongjiang; Zschau, Jochen
2010-01-01
It is common practice in the seismological community to use, especially for large earthquakes, the moment magnitude Mw as a unique magnitude parameter to evaluate the earthquake's damage potential. However, as a static measure of earthquake size, Mw does not provide direct information about the released seismic wave energy and its high frequency content, which is the more interesting information both for engineering purposes and for a rapid assessment of the earthquake's shaking potential. Therefore, we recommend to provide to disaster management organizations besides Mw also sufficiently accurate energy magnitude determinations as soon as possible after large earthquakes. We developed and extensively tested a rapid method for calculating the energy magnitude Me within about 10-15 min after an earthquake's occurrence. The method is based on pre-calculated spectral amplitude decay functions obtained from numerical simulations of Green's functions. After empirical validation, the procedure has been applied offline to a large data set of 767 shallow earthquakes that have been grouped according to their type of mechanism (strike-slip, normal faulting, thrust faulting, etc.). The suitability of the proposed approach is discussed by comparing our rapid Me estimates with Mw published by GCMT as well as with Mw and Me reported by the USGS. Mw is on average slightly larger than our Me for all types of mechanisms. No clear dependence on source mechanism is observed for our Me estimates. In contrast, Me from the USGS is generally larger than Mw for strike-slip earthquakes and generally smaller for the other source types. For ~67 per cent of the event data set our Me differs <= +/-0.3 magnitude units (m.u.) from the respective Me values published by the USGS. However, larger discrepancies (up to 0.8 m.u.) may occur for strike-slip events. A reason of that may be the overcorrection of the energy flux applied by the USGS for this type of earthquakes. We follow the original definition of magnitude scales, which does not apply a priori mechanism corrections to measured amplitudes, also since reliable fault-plane solutions are hardly available within 10-15 min after the earthquake origin time. Notable is that our uncorrected Me data show a better linear correlation and less scatter with respect to Mw than Me of the USGS. Finally, by analysing the recordings of representative recent pairs of strong and great earthquakes, we emphasize the importance of combining Mw and Me in the rapid characterization of the seismic source. They are related to different aspects of the source and may differ occasionally even more than 1 m.u. This highlights the usefulness and importance of providing these two magnitude estimates together for a better assessment of an earthquake's shaking potential and/or tsunamigenic potential.
2011-01-01
Purpose To verify the dose distribution and number of monitor units (MU) for dynamic treatment techniques like volumetric modulated single arc radiation therapy - Rapid Arc - each patient treatment plan has to be verified prior to the first treatment. The purpose of this study was to develop a patient related treatment plan verification protocol using a two dimensional ionization chamber array (MatriXX, IBA, Schwarzenbruck, Germany). Method Measurements were done to determine the dependence between response of 2D ionization chamber array, beam direction, and field size. Also the reproducibility of the measurements was checked. For the patient related verifications the original patient Rapid Arc treatment plan was projected on CT dataset of the MatriXX and the dose distribution was calculated. After irradiation of the Rapid Arc verification plans measured and calculated 2D dose distributions were compared using the gamma evaluation method implemented in the measuring software OmniPro (version 1.5, IBA, Schwarzenbruck, Germany). Results The dependence between response of 2D ionization chamber array, field size and beam direction has shown a passing rate of 99% for field sizes between 7 cm × 7 cm and 24 cm × 24 cm for measurements of single arc. For smaller and larger field sizes than 7 cm × 7 cm and 24 cm × 24 cm the passing rate was less than 99%. The reproducibility was within a passing rate of 99% and 100%. The accuracy of the whole process including the uncertainty of the measuring system, treatment planning system, linear accelerator and isocentric laser system in the treatment room was acceptable for treatment plan verification using gamma criteria of 3% and 3 mm, 2D global gamma index. Conclusion It was possible to verify the 2D dose distribution and MU of Rapid Arc treatment plans using the MatriXX. The use of the MatriXX for Rapid Arc treatment plan verification in clinical routine is reasonable. The passing rate should be 99% than the verification protocol is able to detect clinically significant errors. PMID:21342509
Chakov, Nicole E; Zakharov, Lev N; Rheingold, Arnold L; Abboud, Khalil A; Christou, George
2005-06-27
The syntheses, structures, and magnetic properties are reported of [Mn12O12(O2CPe(t))16(MeOH)4] (4), [Mn6O2(O2CH2)(O2CPe(t))11(HO2CPe(t))2(O2CMe)] (5), [Mn9O6(OH)(CO3)(O2CPe(t))12(H2O)2] (6), and [Mn4O2(O2CPe(t))6(bpy)2] (7, bpy = 2,2'-bipyridine), where Pe(t) = tert-pentyl (Pe(t)CO2H = 2,2-dimethylbutyric acid). These complexes were all prepared from reactions of [Mn12O12(O2CPe(t))16(H2O)4] (3) in CH2Cl2. Complex 4 x 2MeCN crystallizes in the triclinic space group P1 and contains a central [Mn(IV)4O4] cubane core that is surrounded by a nonplanar ring of eight alternating Mn(III) and eight mu3-O(2-) ions. This is only the third Mn12 complex in which the four bound water molecules have been replaced by other ligands, in this case MeOH. Complex 5 x (1/2)CH2Cl2 crystallizes in the monoclinic space group P2(1)/c and contains two [Mn3(mu3-O)]7+ units linked at two of their apexes by two Pe(t)CO2(-) ligands and one mu4-CH2O2(2-) bridge. The complex is a new structural type in Mn chemistry, and also contains only the third example of a gem-diolate unit bridging four metal ions. Complex 6 x H2O x Pe(t)CO2H crystallizes in the orthorhombic space group Cmc2(1) and possesses a [Mn(III)9(mu3-O)6(mu-OH)(mu3-CO3)]12+ core. The molecule contains a mu3-CO3(2-) ion, the first example in a discrete Mn complex. Complex 7 x 2H2O crystallizes in the monoclinic space group P2(1)/c and contains a known [Mn(III)2Mn(II)2(mu3-O)2]6+ core that can be considered as two edge-sharing, triangular [Mn3O] units. Additionally, the synthesis and magnetic properties of a new enneanuclear cluster of formula [Mn9O7(O2CCH2Bu(t))13(THF)2] (8, THF = tetrahydrofuran) are reported. The molecule was obtained by the reaction of [Mn12O12(O2CCH2Bu(t))16(H2O)4] (2) with THF. Complexes 2 and 4 display quasireversible redox couples when examined by cyclic voltammetry in CH2Cl2; oxidations are observed at -0.07 V (2) and -0.21 V (4) vs ferrocene. The magnetic properties of complexes 4-8 have been studied by direct current (DC) and alternating current (AC) magnetic susceptibility techniques. The ground-state spin of 4 was established by magnetization measurements in the 1.80-4.00 K and 0.5-7 T ranges. Fitting of the reduced magnetization data by full matrix diagonalization, incorporating a full powder average and including only axial anisotropy, gave S = 10, g = 2.0(1), and D = -0.39(10) cm(-1). The complex exhibits two frequency-dependent out-of-phase AC susceptibility signals (chi(M)'') indicative of slow magnetization relaxation. An Arrhenius plot obtained from chi(M)'' vs T data gave an effective energy barrier to relaxation (U(eff)) of 62 and 35 K for the slower and faster relaxing species, respectively. These studies suggest that complex 4 is a single-molecule magnet (SMM). DC susceptibility studies on complexes 5-8 display overall antiferromagnetic behavior and indicate ground-state spin values of S < or = 2. AC susceptibility studies at < 10 K confirm these small values and indicate the population of low-lying excited states even at these low temperatures. This supports the small ground-state spin values to be due to spin frustration effects.
Shelton, David; Boreman, Glenn; D'Archangel, Jeffrey
2015-11-10
Infrared metamaterial arrays containing Au elements immersed in a medium of benzocyclobutene (BCB) were fabricated and selectively etched to produce small square flakes with edge dimensions of approximately 20 .mu.m. Two unit-cell designs were fabricated: one employed crossed-dipole elements while the other utilized square-loop elements.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fuller, M.E.; Manning, J.F. Jr.
1996-07-30
The effects of 2,4,6-trinitrotoluene (TNT) on indigenous soil populations and pure bacterial cultures were examined. The number of colony-forming units (CFU) appearing when TNT-contaminated soil was spread on 0.3% molasses plates decreased by 50% when the agar was amended with 67 {mu}g TNT mL{sup -1}, whereas a 99% reduction was observed when uncontaminated soil was plated. Furthermore, TNT-contaminated soil harbored a greater number of organisms able to grow on plates amended with greater than 10 {mu}g TNT mL{sup -1}. The percentage of gram-positive isolates was markedly less in TNT-contaminated soil (7%; 2 of 30) than in uncontaminated soil (61%; 20more » of 33). Pseudomonas aeruginosa, Pseudomonas corrugate, Pseudomonasfluorescens and Alcaligenes xylosoxidans made up the majority of the gram-negative isolates from TNT-contaminated soil. Gram-positive isolates from both soils demonstrated marked growth inhibition when greater than 8-16 {mu}g TNT mL{sup -1} was present in the culture media. Most pure cultures of known aerobic gram-negative organisms readily degraded TNT and evidenced net consumption of reduced metabolites. However, pure cultures of aerobic gram-positive bacteria were sensitive to relatively low concentrations of TNT as indicated by the 50% reduction in growth and TNT transformation which was observed at approximately 10 {mu}g TNT mL{sup -1}. Most non-sporeforming gram-positive organisms incubated in molasses media amended with 80 {mu}g TNT mL{sup -1} or greater became unculturable, whereas all strains tested remained culturable when incubated in mineral media amended with 98 {mu}g TNT mL{sup -1}, indicating that TNT sensitivity is likely linked to cell growth. These results indicate that gram-negative organisms are most likely responsible for any TNT transformation in contaminated soil, due to their relative insensitivity to high TNT concentrations and their ability to transform TNT.« less
Stochastic gravitational wave background from light cosmic strings
DOE Office of Scientific and Technical Information (OSTI.GOV)
DePies, Matthew R.; Hogan, Craig J.
2007-06-15
Spectra of the stochastic gravitational wave backgrounds from cosmic strings are calculated and compared with present and future experimental limits. Motivated by theoretical expectations of light cosmic strings in superstring cosmology, improvements in experimental sensitivity, and recent demonstrations of large, stable loop formation from a primordial network, this study explores a new range of string parameters with masses lighter than previously investigated. A standard 'one-scale' model for string loop formation is assumed. Background spectra are calculated numerically for dimensionless string tensions G{mu}/c{sup 2} between 10{sup -7} and 10{sup -18}, and initial loop sizes as a fraction of the Hubble radiusmore » {alpha} from 0.1 to 10{sup -6}. The spectra show a low frequency power-law tail, a broad spectral peak due to loops decaying at the present epoch (including frequencies higher than their fundamental mode, and radiation associated with cusps), and a flat (constant energy density) spectrum at high frequencies due to radiation from loops that decayed during the radiation-dominated era. The string spectrum is distinctive and unlike any other known source. The peak of the spectrum for light strings appears at high frequencies, significantly affecting predicted signals. The spectra of the cosmic string backgrounds are compared with current millisecond pulsar limits and Laser Interferometer Space Antenna (LISA) sensitivity curves. For models with large stable loops ({alpha}=0.1), current pulsar-timing limits exclude G{mu}/c{sup 2}>10{sup -9}, a much tighter limit on string tension than achievable with other techniques, and within the range of current models based on brane inflation. LISA may detect a background from strings as light as G{mu}/c{sup 2}{approx_equal}10{sup -16}, corresponding to field theory strings formed at roughly 10{sup 11} GeV.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang Jie; Shu Ting; Fan Yuwei
2013-01-28
Time-and-space resolved comparison of the expansion velocities of plasmas in the planar diode with cathodes made of carbon velvet and polymer velvet has been performed. The diode was powered by a 200 kV, 110 ns pulse, and the peak current density was nearly 477 A/cm{sup 2}. A four-channel high speed framing camera (HSFC) was used to observe the formation and subsequent movement of the cathode plasmas. More accurate and valuable information about the two-dimensional (radial and axial) velocity components of the cathode plasmas was also acquired by utilizing the digital image processing methods. Additionally, the perveance model based on themore » Child-Langmuir law was used to calculate the expansion velocities of the diode plasmas from voltage and current profiles. Results from the two diagnostics were compared. Comparing the average values of the radial and axial velocity components indicated that the former was much larger than the latter during the initial period of the current. It was also found that the radial velocity of the carbon velvet cathode (190 cm/{mu}s) was much larger than that (90 cm/{mu}s) of the polymer velvet cathode. Moreover, the average values of both the radial and axial velocity components of the carbon velvet cathode were typically in the range of 2.5 {+-} 1.5 cm/{mu}s, which were smaller than that of the polymer velvet cathode during the current flattop. These results, together with the comparison of calculated values from the perveance model, indicated that the diode with carbon velvet cathode was more robust as compared with the polymer velvet cathode for the same electron current densities.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karimi, A.R.
In this study a method for the measurement of uranium in natural waters at sub-ppB concentration levels by the separation and determination of U/sup 4 +/ and UO/sub 2//sup 2 +/ species is proposed. Reversed phase high performance liquid chromatography, followed by a post-column reaction and a sensitive UV-visible detection system was the method of choice to determine qualitatively and quantitatively the two uranium species. Also a cation-exchange and fluorescence detection system was studied for separation and determination of UO/sub 2//sup 2 +/ ions. Uranyl ion was selectively complexed with L-phenylalanine moetie in the sample solution containing U/sup 4 +/more » ions. Uranium (IV)/U(VI)-ligand was separated on a C/sub 18/ column with acetate buffer. Hexanesulfonate was found to be the choice for ion-pair reagent. The separation was best done with the acetate buffer at .01 M concentration and pH of 3.5. Absorption of the two species were measured after a post-column reaction with Arsenazo-III. Chromatographic parameters were calculated and a calibration curves were constructed. The detection limit for the procedure was 0.7 ..mu..g/mo and 1.2..mu..g/ml for U(IV) and U(VI) respectively. When U(VI) was separated on the cation-exchange column the limit of detection was calculated to be 1 ..mu..g/ml. The direct fluorometric method for U(VI) measurement results in a detection limit of 2 ppB and upper concentration limit of 2 ppM. The effect of interfering ions in the direct method of determination could be eliminated by dilution of sample solution.« less
Nuclear magnetic moment of {sup 69}As from on-line {beta}-NMR on oriented nuclei
DOE Office of Scientific and Technical Information (OSTI.GOV)
Golovko, V.V.; Kraev, I.S.; Phalet, T.
2005-12-15
A precise value for the magnetic moment of the {sup 69}As 5/2{sup -} ground state has been obtained from nuclear magnetic resonance on oriented nuclei (NMR/ON) using the NICOLE {sup 3}He-{sup 4}He dilution refrigerator setup at ISOLDE/CERN. The NMR/ON signal was observed by monitoring the anisotropy of the {sup 69}As {beta} particles. The center frequency {nu}[B{sub ext}=0.0994(10)T]=169.98(9) MHz corresponds to {mu}[{sup 69}As]=+1.6229(16){mu}{sub N}. This result differs considerably from the {pi}f{sub 5/2} single-particle value obtained with g factors for a free proton but is in reasonable agreement with the value obtained with effective g factors and with values from a coremore » polarization calculation and from calculations in the framework of the interacting boson-fermion model. Assuming a single exponential spin-lattice relaxation behavior a relaxation time T{sub 1}{sup '}=10(25) s was observed for {sup 69}AsFe{sub -bar} at a temperature of about 20 mK in a magnetic field B=0.1 T.« less
Approximations used in calculating many-body effects in resonant ((dt. mu. )dee) formation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cohen, J.S.; Leon, M.
1989-02-01
The approximations needed to treat the resonant formation of the compound molecule ((dt..mu..)dee)/sup */ as a line-broadening process are examined. The necessary criteria for applying the impact (Lorentzian) approximation are shown to be seriously violated under the usual conditions of muon-catalyzed fusion. Neither the condition for binary collisions nor the requirement that the detuning not be too large holds. A much more appropriate description is the many-body quasistatic approximation, which is valid for large detunings at any density and for practically the whole profile at high densities. The convenient factorization of the three-body rate into a convolution of a two-bodymore » rate with a broadening factor is shown to hold within some approximations, but the broadening factor itself depends on the transition being considered.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chakraborty, Bipasha; Davies, C. T. H.; de Oliveira, P. G.
We determine the contribution to the anomalous magnetic moment of the muon from themore » $$\\alpha^2_{\\mathrm{QED}}$$ hadronic vacuum polarization diagram using full lattice QCD and including $u/d$ quarks with physical masses for the first time. We use gluon field configurations that include $u$, $d$, $s$ and $c$ quarks in the sea at multiple values of the lattice spacing, multiple $u/d$ masses and multiple volumes that allow us to include an analysis of finite-volume effects. We obtain a result for $$a_{\\mu}^{\\mathrm{HVP,LO}}$$ of $667(6)(12)$, where the first error is from the lattice calculation and the second includes systematic errors from missing QED and isospin-breaking effects and from quark-line disconnected diagrams. Our result implies a discrepancy between the experimental determination of $$a_{\\mu}$$ and the Standard Model of 3$$\\sigma$$.« less
Khalil, Omar S; Yeh, Shu-Jen; Lowery, Michael G; Wu, Xiaomao; Hanna, Charles F; Kantor, Stanislaw; Jeng, Tzyy-Wen; Kanger, Johannes S; Bolt, Rene A; de Mul, Frits F
2003-04-01
We determine temperature effect on the absorption and reduced scattering coefficients (mu(a) and mu(s)(')) of human forearm skin. Optical and thermal simulation data suggest that mu( a) and mu(s)(') are determined within a temperature-controlled depth of approximately 2 mm. Cutaneous mu(s)(') change linearly with temperature. Change in mu(a) was complex and irreversible above body normal temperatures. Light penetration depth (delta) in skin increased on cooling, with considerable person-to-person variations. We attribute the effect of temperature on mu(s)(') to change in refractive index mismatch, and its effect on mu(a) to perfusion changes. The reversible temperature effect on mu (s)(' ) was maintained during more than 90 min. contact between skin and the measuring probe, where temperature was modulated between 38 and 22 degrees C for multiple cycles While temperature modulated mu(s)(' ) instantaneously and reversibly, mu(a) exhibited slower response time and consistent drift. There was a statistically significant upward drift in mu(a) and a mostly downward drift in mu( s)(') over the contact period. The drift in temperature-induced fractional change in mu(s)(') was less statistically significant than the drift in mu(s)('). Deltamu( s)(') values determined under temperature modulation conditions may have less nonspecific drift than mu(s)(') which may have significance for noninvasive determination of analytes in human tissue.
Askeland, Eva; Møllendal, Harald; Uggerud, Einar; Guillemin, Jean-Claude; Aviles Moreno, Juan-Ramon; Demaison, Jean; Huet, Thérèse R
2006-11-23
Z-3-Amino-2-propenenitrile, H2NCH=CHCN, a compound of astrochemical and astrobiological interest, has been studied by Stark and Fourier transform microwave spectroscopy along with eight of its isotopologues; the synthesis of five of these are reported. The spectra of the ground vibrational state and of three vibrationally excited states belonging to the two lowest normal modes were assigned for the parent species, whereas the ground states were assigned for the isotopologues. The frequency of the lowest in-plane bending fundamental vibration was determined to be 152(20) cm(-1) and the frequency of the lowest out-of-plane fundamental mode was found to be 176(20) cm(-1) by relative intensity measurements. A delicate problem is whether this compound is planar or slightly nonplanar. It was found that the rotational constants of the nine species cannot be used to conclude definitely whether the molecule is planar or not. The experimental dipole moment is mu(a) = 16.45(12), mu(b) = 2.86(6), mu(c) = 0 (assumed), and mu(tot.) = 16.70(12) x 10(-30) C m [5.01(4) D]. The quadrupole coupling constants of the two nitrogen nuclei are chi(aa) = -1.4917(21) and chi(cc) = 1.5644(24) MHz for the nitrogen atom of the cyano group and chi(aa) = 1.7262(18) and chi(cc) = -4.0591(17) MHz for the nitrogen atom of the amino group. Extensive quantum-chemical calculations have been performed, and the results obtained from these calculations have been compared with the experimental values. The equilibrium structures of vinylamine, vinyl cyanide, and Z-3-amino-2-propenenitrile have been calculated. These calculations have established that the equilibrium structure of the title compound is definitely nonplanar. However, the MP2/VQZ energy difference between the planar and nonplanar forms is small, only -423 J/mol. Z-Amino-2-propenenitrile and E-3-amino-2-propenenitrile are formed simply by mixing ammonia and cyanoacetylene at room temperature. A plausible reaction path has been modeled. G3 calculations indicate that the enthalpy (298.15 K, 1 atm) of the transition state is about 130 kJ/mol higher than the sum of the enthalpies of the reactants ammonia and cyanoacetylene. This energy difference is comparatively high, which indicates that both E- and Z-3-aminopropenenitrile are not likely to be formed in the gas phase in cold interstellar clouds via a collision between ammonia and cyanoacetylene. An alternative reaction between protonated cyanoacetylene (H-C[triple bond]C-C[triple bond]NH+) and ammonia is predicted to have a much lower activation energy than the reaction between the neutral molecules. Although protonated E- and Z-3-aminopropenenitrile in principle may be formed this way, it is more likely that a collision between NH3 and H-C[triple bond]C-C[triple bond]NH+ leads to NH4+ and H-C[triple bond]C-C[triple bond]N.
Glaser, Thorsten; Heidemeier, Maik; Theil, Hubert; Stammler, Anja; Bögge, Hartmut; Schnack, Jürgen
2010-01-07
The reaction of the tert-butyl-substituted triplesalen ligand H(6)talen(t-Bu(2)) with 2.8 equivalents of Mn(OAc)(2) x 4 H(2)O in MeOH in the presence of NaBPh(4) results in the formation of the one-dimensional (1D) coordination polymer {[{(talen(t-Bu(2)))Mn(3)(MeOH)}(2)(mu(2)-OAc)(3)](mu(2)-OAc)}(n)(BPh(4))(2n) ({[Mn(III)(6)](OAc)}(n)(BPh(4))(2n)) which has been characterized by FTIR, elemental analysis, ESI-MS, single-crystal X-ray diffraction and magnetic measurements. The triplesalen ligand (talen(t-Bu(2)))(6-) provides three salen-like coordination compartments bridged in a meta-phenylene arrangement by a phloroglucinol backbone resulting in the trinuclear Mn(III) base unit {(talen(t-Bu(2)))Mn(3)}(3+). Two of these base units are bridged by three inner acetate ligands giving rise to the hexanuclear complex [{(talen(t-Bu(2)))Mn(3)(MeOH)}(2)(mu(2)-OAc)(3)](3+) ([Mn(III)(6)](3+)). These complexes are bridged by a single external acetate to form a 1D chain as pearls in a pearl necklace. Variable temperature-variable field and mu(eff)vs. T magnetic data have been analyzed in detail by full-matrix diagonalization of the appropriate spin-Hamiltonian consisting of isotropic exchange, zero-field splitting, and Zeeman interaction taking into account the relative orientation of the D-tensors. Satisfactory reproduction of the experimental data have been obtained for parameters sets J(1) = -(0.60 +/- 0.15) cm(-1), J(2) = -(1.05 +/- 0.15) cm(-1), and D(Mn) = -(3.0 +/- 0.7) cm(-1) with J(1) describing the exchange through the phloroglucinol backbone and J(2) describing the exchange through the inner acetates. The non-necessity to incorporate the bridging outer acetates correlates with the longer Mn-O bonds. The experimental data can neither be analyzed without incorporating zero-field splitting nor by the application of a single effective spin ground state.
The Dynamic Mu Transpososome: MuB activation prevents disintegration
Lemberg, Kathryn M.; Schweidenback, Caterina T. H.; Baker, Tania A.
2007-01-01
Summary DNA transposases use a single active center to sequentially cleave the transposable element DNA and join this DNA to a target site. Recombination requires controlled conformational changes within the transposase to ensure that these chemically distinct steps occur at the right time and place, and that the reaction proceeds in the net forward direction. Mu transposition is catalyzed by a stable complex of MuA transposase bound to paired Mu DNA ends (a transpososome). We find that Mu transpososomes efficiently catalyze disintegration when recombination on one end of the Mu DNA is blocked. The MuB activator protein controls the integration vs. disintegration equilibrium. When MuB is present, disintegration occurs slowly and transpososomes that have disintegrated catalyze subsequent rounds of recombination. In the absence of MuB, disintegration goes to completion. These results together with experiments mapping the MuA-MuB contacts during DNA joining suggest that MuB controls progression of recombination by specifically stabilizing a concerted transition to the ‘joining’ configuration of MuA. Thus, we propose that MuB's interaction with the transpososome actively promotes coupled joining of both ends of the element DNA into the same target site and thus may provide a mechanism to antagonize formation of single-end transposition products. PMID:17988683
Motor unit recruitment and EMG power spectra during ramp contractions of a bifunctional muscle.
Dupont, L; Gamet, D; Pérot, C
2000-08-01
Surface electromyograms (EMGs) were analysed on the short and long head of the biceps brachii (BBSH and BBLH) during single (F and S) or dual (F+S) flexion and supination tasks. It was confirmed, by the analysis of EMG root-mean-square (RMS) values, that the highest activations of BBSH and BBLH were obtained during a maximal dual task. This study was essentially concerned with the analysis of power spectra data obtained during progressive or ramp contractions (RCs). The shape of the power spectra established during the first second of the RCs differs between F, S and F+S tasks. Differences in mean power frequency (MPF) calculated during RCs would be representative of a recruitment of motor units (MUs) that is, at least partly, task-dependent. In order to compare MPF values calculated from RCs performed under different mechanical conditions (F, S and F+S), MPF-RMS(PSD) relationships have been established (RMS(PSD) being defined as the power spectrum density RMS). Both BBSH and BBLH exhibited initial MPF values higher in supination RC than in flexion RC. Because of plateau values reached at the same level of muscle activation whatever the task performed, the slope of the MPF-RMS(PSD) relationship was lower in S than in F. These results are in favour of MU recruitment that is, at least partly, different in F and in S conditions. Dual submaximal tasks seem to mix the activation of the F and S subpopulations of MUs as revealed by the spectral parameters obtained during F+S ramp contractions. This study could find some implication in the field of muscle rehabilitation or reinforcement.
Cabon, Nolwenn; Petillon, Francois Y; Schollhammer, Philippe; Talarmin, Jean; Muir, Kenneth W
2004-09-07
The reaction of mono- or dichloro-dimolybdenum(III) complexes [Mo2Cp2(mu-SMe)2(mu-Cl)(mu-Y)] (Cp=eta5-C5H5; 1, Y=SMe; 2, Y=PPh2; 3, Y=Cl) with NaBH4 at room temperature gave in high yields tetrahydroborato (8), hydrido (9) or metallaborane (12) complexes depending on the ancillary ligands. The correct formulation of derivatives and has been unambigously determined by X-ray diffraction methods. That of the hydrido compound 9 has been established in solution by NMR analysis and confirmed by an X-ray study of the mu-azavinylidene derivative [Mo2Cp2(mu-SMe)2(mu-PPh2)(mu-N=CHMe)] (10) obtained from the insertion of acetonitrile into the Mo-H bond of 9. Reaction of NaBH4 with nitrile derivatives, [Mo2Cp2(mu-SMe)4-n(CH3CN)2n]n+(5, n=1; 6 n=2), afforded the tetrahydroborato compound 8, together with a mu-azavinylidene species [Mo2Cp2(mu-SMe)3(mu-N=CHMe)](14), when n=1, and the metallaborane complex 12, together with a mixed borohydrato-azavinylidene derivative [Mo2Cp2(mu-SMe)2(mu-BH4)(mu-N=CHMe)] (13), when n=2. The molecular structures of these complexes have been confirmed by X-ray analysis. Preparations of some of the starting complexes (3 and 4) are also described, as are the molecular structures of the precursors [Mo2Cp2(mu-SMe)2(mu-X)(mu-Y)] (1, X/Y=Cl/SMe; 2, X/Y=Cl/PPh2; 4, X/Y=SMe/PPh2).
Forniés, Juan; Fortuño, Consuelo; Ibáñez, Susana; Martín, Antonio
2008-07-07
Reaction of unsaturated (44e (-) skeleton) [PdPt 2(mu-PPh 2) 2(mu-P 2Ph 4)(R F) 4] 4 with Br (-) produces the saturated (48e (-) skeleton) complex [NBu 4][(R F) 2Pt(mu-PPh 2)(mu-Br)Pd(mu-PPh 2)(mu-P 2Ph 4)Pt(R F) 2] 5 without any M-M' bond. Attempts to eliminate Br (-) of 5 with Ag (+) in CH 2Cl 2 as a solvent gives a mixture of [(R F) 2Pt (III)(mu-PPh 2) 2Pt (III)(R F) 2] and some other unidentified products as a consequence of oxidation and partial fragmentation. However, when the reaction of 5 with Ag (+) is carried out in CH 3CN, no oxidation is observed but the elimination of Br (-) and the formation of [(R F) 2(CH 3CN)Pt(mu-PPh 2)Pd(mu-PPh 2)(mu-P 2Ph 4)Pt(R F) 2] 6 (46e (-) skeleton), a complex with a Pt-Pd bond, takes place. It is noteworthy that the reaction of 5 with TlPF 6 in CH 2Cl 2 does not precipitate TlBr but forms the adduct [(R F) 2PtTl(mu-PPh 2)(mu-Br)Pd(mu-PPh 2)(mu-P 2Ph 4)Pt(R F) 2] 7 with a Pt-Tl bond. Likewise, 5 reacts with [AgOClO 3(PPh 3)] in CH 2Cl 2 forming the adduct [AgPdPt 2(mu-Br)(mu-PPh 2) 2(mu-Ph 2P-PPh 2)(R F) 4(PPh 3)] 8, which contains a Pt-Ag bond. Both adducts are unstable in a CH 3CN solution, precipitating TlBr or AgBr and yielding the unsaturated 6. The treatment of [NBu 4] 2[(R F) 2Pt(mu-PPh 2) 2Pd(mu-PPh 2) 2Pt(R F) 2] in CH 3CN with I 2 (1:1 molar ratio) at 233 K yields a mixture of 4 and 6, which after recrystallization from CH 2Cl 2 is totally converted in 4. If the reaction with I 2 is carried out at room temperature, a mixture of the isomers [NBu 4][(R F) 2Pt(mu-PPh 2)(mu-I)Pd(mu-PPh 2)(mu-P 2Ph 4)Pt(R F) 2] 9 and [NBu 4][(R F)(PPh 2R F)Pt(mu-PPh 2)(mu-I)Pd(mu-PPh 2) 2Pt(R F) 2] 10 are obtained. The structures of the complexes have been established on the bases of NMR data, and the X-ray structures of 5- 8 have been studied. The relationship between the different complexes has been studied.
Uranium hexafluoride public risk
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fisher, D.R.; Hui, T.E.; Yurconic, M.
1994-08-01
The limiting value for uranium toxicity in a human being should be based on the concentration of uranium (U) in the kidneys. The threshold for nephrotoxicity appears to lie very near 3 {mu}g U per gram kidney tissue. There does not appear to be strong scientific support for any other improved estimate, either higher or lower than this, of the threshold for uranium nephrotoxicity in a human being. The value 3 {mu}g U per gram kidney is the concentration that results from a single intake of about 30 mg soluble uranium by inhalation (assuming the metabolism of a standard person).more » The concentration of uranium continues to increase in the kidneys after long-term, continuous (or chronic) exposure. After chronic intakes of soluble uranium by workers at the rate of 10 mg U per week, the concentration of uranium in the kidneys approaches and may even exceed the nephrotoxic limit of 3 {mu}g U per gram kidney tissue. Precise values of the kidney concentration depend on the biokinetic model and model parameters assumed for such a calculation. Since it is possible for the concentration of uranium in the kidneys to exceed 3 {mu}g per gram tissue at an intake rate of 10 mg U per week over long periods of time, we believe that the kidneys are protected from injury when intakes of soluble uranium at the rate of 10 mg U per week do not continue for more than two consecutive weeks. For long-term, continuous occupational exposure to low-level, soluble uranium, we recommend a reduced weekly intake limit of 5 mg uranium to prevent nephrotoxicity in workers. Our analysis shows that the nephrotoxic limit of 3 {mu}g U per gram kidney tissues is not exceeded after long-term, continuous uranium intake at the intake rate of 5 mg soluble uranium per week.« less
Automated cloud classification with a fuzzy logic expert system
NASA Technical Reports Server (NTRS)
Tovinkere, Vasanth; Baum, Bryan A.
1993-01-01
An unresolved problem in current cloud retrieval algorithms concerns the analysis of scenes containing overlapping cloud layers. Cloud parameterizations are very important both in global climate models and in studies of the Earth's radiation budget. Most cloud retrieval schemes, such as the bispectral method used by the International Satellite Cloud Climatology Project (ISCCP), have no way of determining whether overlapping cloud layers exist in any group of satellite pixels. One promising method uses fuzzy logic to determine whether mixed cloud and/or surface types exist within a group of pixels, such as cirrus, land, and water, or cirrus and stratus. When two or more class types are present, fuzzy logic uses membership values to assign the group of pixels partially to the different class types. The strength of fuzzy logic lies in its ability to work with patterns that may include more than one class, facilitating greater information extraction from satellite radiometric data. The development of the fuzzy logic rule-based expert system involves training the fuzzy classifier with spectral and textural features calculated from accurately labeled 32x32 regions of Advanced Very High Resolution Radiometer (AVHRR) 1.1-km data. The spectral data consists of AVHRR channels 1 (0.55-0.68 mu m), 2 (0.725-1.1 mu m), 3 (3.55-3.93 mu m), 4 (10.5-11.5 mu m), and 5 (11.5-12.5 mu m), which include visible, near-infrared, and infrared window regions. The textural features are based on the gray level difference vector (GLDV) method. A sophisticated new interactive visual image Classification System (IVICS) is used to label samples chosen from scenes collected during the FIRE IFO II. The training samples are chosen from predefined classes, chosen to be ocean, land, unbroken stratiform, broken stratiform, and cirrus. The November 28, 1991 NOAA overpasses contain complex multilevel cloud situations ideal for training and validating the fuzzy logic expert system.
PAF involvement in dermal extravasation in the reverse passive Arthus reaction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deacon, R.W.; Melden, M.K.; Saunders, R.N.
The reverse passive erthus reaction (RPAR) is characterized by PMN infiltration, increased vascular permeability leading to plasma extravasation and vessel damage. In the skin RPAR is an inflammatory response initiated by deposition of immune complexes and attributed to complement activation. As PAF can elicit similar dermal reactions, they examined the PAF antagonist SRI 63-072 in the RPAR. Guinea pigs were given an i.v. injection of /sup 125/I-BSA (Ag-20 mg/kg with 20 mg/kg Evan's blue as a permeability tracer), followed by intradermal (i.d.) injections (0.1 ml/site) of anti-BSA antibodies (Ab). After 30 min, dermal sites (2 cm diam.) were removed, countedmore » and the ..mu..l plasma/site (over background counts) calculated from plasma radioactivity measurements. The plasma leakage (..mu..l plasma/site) was dose-dependent upon Ab dose (6-200 ..mu..g/site). At the ultrastructural level, the presence of neutrophils and eosinophils were observed in the extravascular spaces. The luminal endothelium exhibited cytotoxic characteristics and loss of junctional integrity. SRI 63-072 exhibited 50% maximal inhibition when given i.d. with the Ab (0.1 ..mu..g/site) but only 5-10% when given at 3.0 mg/kg i.v. with Ag. No further inhibition of dermal extravasation was observed using SRI 63-441, a competitive receptor antagonist with 3-30 fold the in vivo potency of SRI 63-072. As dermal extravasation in RPAR is only partially inhibited by a PAF antagonist, it appears that other vasoactive mediators, possibly histamine, may be influencing vessel permeability as well.« less
Fleming, Donald G; Bridges, Michael D; Arseneau, Donald J; Chen, Ya Kun; Wang, Yan Alexander
2011-04-07
Reported here is the first μSR study of the muon (A(μ)) and proton (A(p)) β-hyperfine coupling constants (Hfcc) of muoniated sec-butyl radicals, formed by muonium (Mu) addition to 1-butene and to cis- and trans-2-butene. The data are compared with in vacuo spin-unrestricted MP2 and hybrid DFT/B3YLP calculations reported in the previous paper (I), which played an important part in the interpretation of the data. The T-dependences of both the (reduced) muon, A(μ)′(T), and proton, A(p)(T), Hfcc are surprisingly well explained by a simple model, in which the calculated Hfcc from paper I at energy minima of 0 and near ±120° are thermally averaged, assuming an energy dependence given by a basic 2-fold torsional potential. Fitted torsional barriers to A(μ)′(T) from this model are similar (~3 kJ/mol) for all muoniated butyl radicals, suggesting that these are dominated by ZPE effects arising from the C−Mu bond, but for A(p)(T) exhibit wide variations depending on environment. For the cis- and trans-2-butyl radicals formed from 2-butene, A(μ)′(T) exhibits clear discontinuities at bulk butene melting points, evidence for molecular interactions enhancing these muon Hfcc in the environment of the solid state, similar to that found in earlier reports for muoniated tert-butyl. In contrast, for Mu−sec-butyl formed from 1-butene, there is no such discontinuity. The muon hfcc for the trans-2-butyl radical are seemingly very well predicted by B3LYP calculations in the solid phase, but for sec-butyl from 1-butene, showing the absence of further interactions, much better agreement is found with the MP2 calculations across the whole temperature range. Examples of large proton Hfcc near 0 K are also reported, due to eclipsed C−H bonds, in like manner to C−Mu, which then also exhibit clear discontinuities in A(p)(T) at bulk melting points. The data suggest that the good agreement found between theory and experiment from the B3LYP calculations for eclipsed bonds in the solid phase may be fortuitous. For the staggered protons of the sec-butyl radicals formed, no discontinuities are seen at all in A(p)(T), also demonstrating no further effects of molecular interactions on these particular proton Hfcc.
Shen, H; Zhao, S H; Cao, J H; Li, X Y; Fan, B
2011-11-01
Muscle specific RING finger protein2 (MuRF2) and Muscle specific RING finger protein3(MuRF3) are two important members of the muscle specific RING finger protein family, which are especially expressed in cardiac and skeletal muscle tissues and play critical roles during the myocyte differentiation, development and morphogenesis. In this study, the molecular characteristics of porcine MuRF2 and MuRF3 gene were reported, and furthermore two variants of MuRF2 were identified. The tissue distribution pattern analyses revealed that MuRF2-b and MuRF3 mRNA was exclusively expressed in striated muscle tissues while MuRF2-a had a low-level expression in liver tissue. Real-time quantitative reverse transcriptase-polymerase chain reaction (RT-qPCR) results displayed MuRF2 mRNA expression levels were significantly varied at three stages of fetal skeletal muscle in Landrace pigs, and the expression of MuRF2-a was lower than that of MuRF2-b in all stages. An essencial region of -396 to -22 for transcription was identified at the 5'UTR of porcine MuRF2 gene, while no active regulatory fragment found in the 5'UTR of mouse MuRF2. A single nucleotide polymorphism (SNP), c.915G > A was identified in MuRF2 exon 5. A HinfI PCR-RFLP was developed for SNP genotyping in two different pig populations. Association of the genotypes with growth and carcass traits showed that different genotypes of MuRF2 were significantly (P < 0.05) associated with average daily gain on test, carcass weight and carcass length. The study suggested that the porcine MuRF2 and MuRF3 genes are involved in the muscle growth and development, and can be considered as potential candidate genes affecting muscle production traits in the pig.
MuSK IgG4 autoantibodies cause myasthenia gravis by inhibiting binding between MuSK and Lrp4
Huijbers, Maartje G.; Zhang, Wei; Klooster, Rinse; Niks, Erik H.; Friese, Matthew B.; Straasheijm, Kirsten R.; Thijssen, Peter E.; Vrolijk, Hans; Plomp, Jaap J.; Vogels, Pauline; Losen, Mario; Van der Maarel, Silvère M.; Burden, Steven J.; Verschuuren, Jan J.
2013-01-01
Myasthenia gravis (MG) is a severely debilitating autoimmune disease that is due to a decrease in the efficiency of synaptic transmission at neuromuscular synapses. MG is caused by antibodies against postsynaptic proteins, including (i) acetylcholine receptors, the neurotransmitter receptor, (ii) muscle-specific kinase (MuSK), a receptor tyrosine kinase essential for the formation and maintenance of neuromuscular synapses, and (iii) low-density lipoprotein receptor-related protein 4 (Lrp4), which responds to neural Agrin by binding and stimulating MuSK. Passive transfer studies in mice have shown that IgG4 antibodies from MuSK MG patients cause disease without requiring complement or other immune components, suggesting that these MuSK antibodies cause disease by directly interfering with MuSK function. Here we show that pathogenic IgG4 antibodies to MuSK bind to a structural epitope in the first Ig-like domain of MuSK, prevent binding between MuSK and Lrp4, and inhibit Agrin-stimulated MuSK phosphorylation. In contrast, these IgG4 antibodies have no direct effect on MuSK dimerization or MuSK internalization. These results provide insight into the unique pathogenesis of MuSK MG and provide clues toward development of specific treatment options. PMID:24297891
MuSICa at GRIS: a prototype image slicer for EST at GREGOR
NASA Astrophysics Data System (ADS)
Calcines, A.; Collados, M.; López, R. L.
2013-05-01
This communication presents a prototype image slicer for the 4-m European Solar Telescope (EST) designed for the spectrograph of the 1.5-m GREGOR solar telescope (GRIS). The design of this integral field unit has been called MuSICa (Multi-Slit Image slicer based on collimator-Camera). It is a telecentric system developed specifically for the integral field, high resolution spectrograph of EST and presents multi-slit capability, reorganizing a bidimensional field of view of 80 arcsec^{2} into 8 slits, each one of them with 200 arcsec length × 0.05 arcsec width. It minimizes the number of optical components needed to fulfil this multi-slit capability, three arrays of mirrors: slicer, collimator and camera mirror arrays (the first one flat and the other two spherical). The symmetry of the layout makes it possible to overlap the pupil images associated to each part of the sliced entrance field of view. A mask with only one circular aperture is placed at the pupil position. This symmetric characteristic offers some advantages: facilitates the manufacturing process, the alignment and reduces the costs. In addition, it is compatible with two modes of operation: spectroscopic and spectro-polarimetric, offering a great versatility. The optical quality of the system is diffraction-limited. The prototype will improve the performances of GRIS at GREGOR and is part of the feasibility study of the integral field unit for the spectrographs of EST. Although MuSICa has been designed as a solar image slicer, its concept can also be applied to night-time astronomical instruments (Collados et al. 2010, Proc. SPIE, Vol. 7733, 77330H; Collados et al. 2012, AN, 333, 901; Calcines et al. 2010, Proc. SPIE, Vol. 7735, 77351X)
NASA Technical Reports Server (NTRS)
Stallkamp, J. A.
1977-01-01
Speed profiles of rail passenger service between New York City and Washington, D.C. were developed and showed progressively fewer speed restrictions and increasing maximum speeds. The significant equipment characteristics include the portion of the total weight on driven axles, i.e., multiple unit (MU) cars versus locomotive hauled trains, and the short term tractive effort rating of the motors. The ratio of acceleration plus braking time to total time is provided for validation of the use of the short term propulsion equipment ratings. Absolute trip times are shown to be determined primarily by the allowed speed profile. Locomotive hauled train weights and lengths and the locomotive capabilities and characteristics that are required to make the performance of this type of train comparable to that of MU trains are given.
Crystallization and preliminary X-ray analysis of gene product 44 from bacteriophage Mu
Kondou, Youhei; Kitazawa, Daisuke; Takeda, Shigeki; Yamashita, Eiki; Mizuguchi, Mineyuki; Kawano, Keiichi; Tsukihara, Tomitake
2005-01-01
Bacteriophage Mu baseplate protein gene product 44 (gp44) is an essential protein required for the assembly of viable phages. To investigate the roles of gp44 in baseplate assembly and infection, gp44 was crystallized at pH 6.0 in the presence of 20% 2-methyl-2,4-pentanediol. The crystals belong to space group R3, with unit-cell parameters a = b = 127.47, c = 63.97 Å. The crystals diffract X-rays to at least 2.1 Å resolution and are stable in the X-ray beam and are therefore appropriate for structure determination. Native data have been collected to 2.1 Å resolution using a DIP6040 image-plate system at beamline BL44XU at the SPring-8 facility in Japan. PMID:16508104
Alamgir, A S M; Owens, Nick; Lavignon, Marc; Malik, Frank; Evans, Leonard H
2005-04-01
Polytropic murine leukemia viruses (MuLVs) are generated by recombination of ecotropic MuLVs with env genes of a family of endogenous proviruses in mice, resulting in viruses with an expanded host range and greater virulence. Inbred mouse strains contain numerous endogenous proviruses that are potential donors of the env gene sequences of polytropic MuLVs; however, the precise identification of those proviruses that participate in recombination has been elusive. Three different structural groups of proviruses in NFS/N mice have been described and different ecotropic MuLVs preferentially recombine with different groups of proviruses. In contrast to other ecotropic MuLVs such as Friend MuLV or Akv that recombine predominantly with a single group of proviruses, Moloney MuLV (M-MuLV) recombines with at least two distinct groups. In this study, we determined that only three endogenous proviruses, two of one group and one of another group, are major participants in recombination with M-MuLV. Furthermore, the distinction between the polytropic MuLVs generated by M-MuLV and other ecotropic MuLVs is the result of recombination with a single endogenous provirus. This provirus exhibits a frameshift mutation in the 3' region of the surface glycoprotein-encoding sequences that is excluded in recombinants with M-MuLV. The sites of recombination between the env genes of M-MuLV and endogenous proviruses were confined to a short region exhibiting maximum homology between the ecotropic and polytropic env sequences and maximum stability of predicted RNA secondary structure. These observations suggest a possible mechanism for the specificity of recombination observed for different ecotropic MuLVs.
Cole, R N; Ghazanfari, N; Ngo, S T; Gervásio, O L; Reddel, S W; Phillips, W D
2010-01-01
The postsynaptic muscle-specific kinase (MuSK) coordinates formation of the neuromuscular junction (NMJ) during embryonic development. Here we have studied the effects of MuSK autoantibodies upon the NMJ in adult mice. Daily injections of IgG from four MuSK autoantibody-positive myasthenia gravis patients (MuSK IgG; 45 mg day−1i.p. for 14 days) caused reductions in postsynaptic ACh receptor (AChR) packing as assessed by fluorescence resonance energy transfer (FRET). IgG from the patients with the highest titres of MuSK autoantibodies caused large (51–73%) reductions in postsynaptic MuSK staining (cf. control mice; P < 0.01) and muscle weakness. Among mice injected for 14 days with control and MuSK patient IgGs, the residual level of MuSK correlated with the degree of impairment of postsynaptic AChR packing. However, the loss of postsynaptic MuSK preceded this impairment of postsynaptic AChR. When added to cultured C2 muscle cells the MuSK autoantibodies caused tyrosine phosphorylation of MuSK and the AChR β-subunit, and internalization of MuSK from the plasma membrane. The results suggest a pathogenic mechanism in which MuSK autoantibodies rapidly deplete MuSK from the postsynaptic membrane leading to progressive dispersal of postsynaptic AChRs. Moreover, maintenance of postsynaptic AChR packing at the adult NMJ would appear to depend upon physical engagement of MuSK with the AChR scaffold, notwithstanding activation of the MuSK-rapsyn system of AChR clustering. PMID:20603331
Leptonic decays of charged D and Ds mesons
NASA Astrophysics Data System (ADS)
Menaa, Nabil
Using 281 pb--1 of data taken on the psi(3770) resonance and 314 pb--1 of data near or at 4170 MeV collected with the CLEO-c detector, we present two analyses to study the purely leptonic decays of charmed and charmed strange charged mesons. In the first analysis, we extract a relatively precise value for the decay constant of the D+ meson by measuring B (D+ → mu+nu) = (4.40 +/- 0.66+0.09-0.12 ) x 10-4. We find fD + = (222.6 +/- 16.7+2.8-3.4 ) MeV, and compare with current theoretical calculations. We also set a 90% confidence upper limit on B (D+ → e +nu) < 2.4 x 10-5 which constrains new physics models. Finally with this data sample, we test whether or not the tau lepton manifests the same couplings as the mu lepton by investigating the relative decay rates in purely leptonic D+ meson decays. We limit B (D+ → tau+nu) < 2.1 x 10--3 at 90% confidence level (C. L.), thus allowing us to place the first upper limit on the ratio R = Gamma (D+ → tau+nu)/Gamma( D+ → mu+nu). The ratio of R to the Standard Model expectation of 2.65 then is <1.8 at 90% C. L., consistent with the prediction of lepton universality. In the second analysis, we examine e+ e-- → D-sD*+s and D-*sD+s interactions at 4170 MeV using the CLEO-c detector in order to measure the decay constant fD+s . We use the D+s → ℓ+nu channel, where the ℓ+ designates either a mu+ or a tau+, when the tau+ → pi+nu. Analyzing both modes independently, we determine B ( D+s → mu+nu) = (0.594 +/- 0.066 +/- 0.031)%, B ( D+s → tau+nu) = (8.0 +/- 1.3 +/- 0.4)%. We also analyze them simultaneously to find an effective value of B ( D+s → mu+nu) = (0.621 +/- 0.058 +/- 0.032)% and extract fD+s = 270 +/- 13 +/- 7 MeV. Combining with our previous determination of B (D+ → mu+nu), we also find the ratio fD+s/fD+ = 1.21 +/- 0.11 +/- 0.04. We compare with current theoretical estimates. Finally, we limit B ( D+s → e+nu) < 1.3 x 10 --4 at 90% confidence level.
Localised task-dependent motor-unit recruitment in the masseter.
Schindler, H J; Hellmann, D; Giannakopoulos, N N; Eiglsperger, U; van Dijk, J P; Lapatki, B G
2014-07-01
Localised motor-unit (MU) recruitment in the masseter was analysed in this study. We investigated whether differential activation behaviour, which has already been reported for distant masseter regions, can also be detected in small muscle subvolumes at the level of single MUs. Two bipolar fine-wire electrodes and an intra-oral 3D bite-force transmitter were used to record intra-muscular electromyograms (EMG) resulting from controlled bite-forces of 10 healthy human subjects (mean age 24.1 ± 1.2 years). Two-hundred and seventeen decomposed MUs were organised into localised MU task groups with different (P < 0.001) force-direction-specific behaviour. Proportions of MUs involved in one, two, three or four examined tasks were 46%, 31%, 18% and 5%, respectively. This study provides evidence of the ability of the neuromuscular system to modify the mechanical output of small masseter subvolumes by differential control of adjacent MUs belonging to distinct task groups. Localised differential activation behaviour of the masseter may be the crucial factor enabling highly flexible and efficient adjustment of the muscle activity in response to complex local biomechanical needs, for example, continually varying bite-forces during the demanding masticatory process. © 2014 John Wiley & Sons Ltd.
Response of Cultured Maize Cells to (+)-Abscisic Acid, (-)-Abscisic Acid, and Their Metabolites.
Balsevich, J. J.; Cutler, A. J.; Lamb, N.; Friesen, L. J.; Kurz, E. U.; Perras, M. R.; Abrams, S. R.
1994-01-01
The metabolism and effects of (+)-S- and (-)-R-abscisic acid (ABA) and some metabolites were studied in maize (Zea mays L. cv Black Mexican Sweet) suspension-cultured cells. Time-course studies of metabolite formation were performed in both cells and medium via analytical high-performance liquid chromatography. Metabolites were isolated and identified using physical and chemical methods. At 10 [mu]M concentration and 28[deg] C, (+)-ABA was metabolized within 24 h, yielding natural (-)-phaseic acid [(-)-PA] as the major product. The unnatural enantiomer (-)-ABA was less than 50% metabolized within 24 h and gave primarily (-)-7[prime]-hydroxyABA [(-)-7[prime]-HOABA], together with (+)-PA and ABA glucose ester. The distribution of metabolites in cells and medium was different, reflecting different sites of metabolism and membrane permeabilities of conjugated and nonconjugated metabolites. The results imply that (+)-ABA was oxidized to (-)-PA inside the cell, whereas (-)-ABA was converted to (-)-7[prime]-HOABA at the cell surface. Growth of maize cells was inhibited by both (+)- and (-)-ABA, with only weak contributions from their metabolites. The concentration of (+)-ABA that caused a 50% inhibition of growth of maize cells was approximately 1 [mu]M, whereas that for its metabolite (-)-PA was approximately 50 [mu]M. (-)-ABA was less active than (+)-ABA, with 50% growth inhibition observed at about 10 [mu]M. (-)-7[prime]-HOABA was only weakly active, with 50% inhibition caused by approximately 500 [mu]M. Time-course studies of medium pH indicated that (+)-ABA caused a transient pH increase (+0.3 units) at 6 h after addition that was not observed in controls or in samples treated with (-)-PA. The effect of (-)-ABA on medium Ph was marginal. No racemization at C-1[prime] of (+)-ABA, (-)-ABA, or metabolites was observed during the studies. PMID:12232311
Kure, Bunsho; Matsumoto, Takahiro; Ichikawa, Koji; Fukuzumi, Shunichi; Higuchi, Yoshiki; Yagi, Tatsuhiko; Ogo, Seiji
2008-09-21
The pH-dependent hydrogen isotope exchange reaction between gaseous isotopes and medium isotopes and hydrogenation of the carbonyl compounds have been investigated with water-soluble bis(mu-thiolate)(mu-hydride)NiRu complexes, Ni(II)(mu-SR)(2)(mu-H)Ru(II) {(mu-SR)(2) = N,N'-dimethyl-N,N'-bis(2-mercaptoethyl)-1,3-propanediamine}, as functional models for [NiFe]hydrogenases. In acidic media (at pH 4-6), the mu-H ligand of the Ni(II)(mu-SR)(2)(mu-H)Ru(II) complexes has H(+) properties, and the complexes catalyse the hydrogen isotope exchange reaction between gaseous isotopes and medium isotopes. A mechanism of the hydrogen isotope exchange reaction between gaseous isotopes and medium isotopes through a low-valent Ni(I)(mu-SR)(2)Ru(I) complex is proposed. In contrast, in neutral-basic media (at pH 7-10), the mu-H ligand of the Ni(II)(mu-SR)(2)(mu-H)Ru(II) complexes acts as H(-), and the complexes catalyse the hydrogenation of carbonyl compounds.
Lisnard, Laurent; Mialane, Pierre; Dolbecq, Anne; Marrot, Jérôme; Clemente-Juan, Juan Modesto; Coronado, Eugenio; Keita, Bineta; de Oliveira, Pedro; Nadjo, Louis; Sécheresse, Francis
2007-01-01
Five Co(II) silicotungstate complexes are reported. The centrosymmetric heptanuclear compound K(20)[{(B-beta-SiW(9)O(33)(OH))(beta-SiW(8)O(29)(OH)(2))Co(3)(H(2)O)}(2)Co(H(2)O)(2)]47 H(2)O (1) consists of two {(B-beta-SiW(9)O(33)(OH))(beta-SiW(8)O(29)(OH)(2))Co(3)(H(2)O)} units connected by a {CoO(4)(H(2)O)(2)} group. In the chiral species K(7)[Co(1.5)(H(2)O)(7))][(gamma-SiW(10)O(36))(beta-SiW(8)O(30)(OH))Co(4)(OH)(H(2)O)(7)]36 H(2)O (2), a {gamma-SiW(10)O(36)} and a {beta-SiW(8)O(30)(OH)} unit enclose a mononuclear {CoO(4)(H(2)O)(2)} group and a {Co(3)O(7)(OH)(H(2)O)(5)} fragment. The two trinuclear Co(II) clusters present in 1 enclose a mu(4)-O atom, while in 2 a mu(3)-OH bridging group connects the three paramagnetic centers of the trinuclear unit, inducing significantly larger Co-L-Co (L=mu(4)-O (1), mu(3)-OH (2)) bridging angles in 2 (theta(av(Co-L-Co))=99.1 degrees ) than in 1 (theta(av(Co-L-Co))=92.8 degrees ). Weaker ferromagnetic interactions were found in 2 than in 1, in agreement with larger Co-L-Co angles in 2. The electrochemistry of 1 was studied in detail. The two chemically reversible redox couples observed in the positive potential domain were attributed to the redox processes of Co(II) centers, and indicated that two types of Co(II) centers in the structure were oxidized in separate waves. Redox activity of the seventh Co(II) center was not detected. Preliminary experiments indicated that 1 catalyzes the reduction of nitrite and NO. Remarkably, a reversible interaction exists with NO or related species. The hybrid tetranuclear complexes K(5)Na(3)[(A-alpha-SiW(9)O(34))Co(4)(OH)(3)(CH(3)COO)(3)]18 H(2)O (3) and K(5)Na(3)[(A-alpha-SiW(9)O(34))Co(4)(OH)(N(3))(2)(CH(3)COO)(3)]18 H(2)O (4) were characterized: in both, a tetrahedral {Co(4)(L(1))(L(2))(2)(CH(3)COO)(3)} (3: L(1)=L(2)=OH; 4: L(1)=OH, L(2)=N(3)) unit capped the [A-alpha-SiW(9)O(34)](10-) trivacant polyanion. The octanuclear complex K(8)Na(8)[(A-alpha-SiW(9)O(34))(2)Co(8)(OH)(6)(H(2)O)(2)(CO(3))(3)]52 H(2)O (5), containing two {Co(4)O(9)(OH)(3)(H(2)O)} units, was also obtained. Compounds 2, 3, 4, and 5 were less stable than 1, but their partial electrochemical characterization was possible; the electronic effect expected for 3 and 4 was observed.
Safety of formalin treatments on warm- and coolwater fish eggs
Rach, Jeff J.; Howe, George E.; Schreier, Theresa M.
1997-01-01
Formalin is widely used for treating fungal infections of fish eggs in intensive aquaculture operations. The use of formalin in the United States is only allowed on salmonid and esocid eggs unless a special exemption is granted for use on other species. This study was conducted to determine the safety of formalin treatments on eggs of representative warm- and coolwater fish species and data was used to support a request to allow the use of formalin on the eggs of warmwater and additional coolwater fish species. Non-eyed eggs of walleye (Stizostedion vitreum), common carp (Cyprinus carpio), white sucker (Catostomus commersoni), channel catfish (Ictalurus punctatus), and lake sturgeon (Acipenser fulvescens) were cultured in miniature egg hatching jars and treated for 45 min every-other-day with 1500, 4500, or 7500 μL L-1 formalin up to hatch. For all species tested, the percent hatch was greater in 1500 mu L L-1 treatment groups than in untreated controls. Walleye eggs were the least sensitive species and had a hatch of 87% in the 7500 mu L L-1 treatment. Lake sturgeon were the most sensitive species with a mean hatch of 54% in 1500 mu L L-1 treatments. Adequate margins of safety exist for standard treatments (1500 mu L L-1 for 15 min) on eggs of all species tested except lake sturgeon. Fungal infections drastically reduced or eliminated hatch in most control groups whereas most treated groups were free of infections. This confirms the efficacy of formalin as an fungicide. Published by Elsevier Science B.V.
Ramakrishnan, Divakar; Curtis, Wayne R
2004-10-20
Trickle-bed root culture reactors are shown to achieve tissue concentrations as high as 36 g DW/L (752 g FW/L) at a scale of 14 L. Root growth rate in a 1.6-L reactor configuration with improved operational conditions is shown to be indistinguishable from the laboratory-scale benchmark, the shaker flask (mu=0.33 day(-1)). These results demonstrate that trickle-bed reactor systems can sustain tissue concentrations, growth rates and volumetric biomass productivities substantially higher than other reported bioreactor configurations. Mass transfer and fluid dynamics are characterized in trickle-bed root reactors to identify appropriate operating conditions and scale-up criteria. Root tissue respiration goes through a minimum with increasing liquid flow, which is qualitatively consistent with traditional trickle-bed performance. However, liquid hold-up is much higher than traditional trickle-beds and alternative correlations based on liquid hold-up per unit tissue mass are required to account for large changes in biomass volume fraction. Bioreactor characterization is sufficient to carry out preliminary design calculations that indicate scale-up feasibility to at least 10,000 liters.
Changes in the quality of care during progress from stage 1 to stage 2 of Meaningful Use.
Levine, David M; Healey, Michael J; Wright, Adam; Bates, David W; Linder, Jeffrey A; Samal, Lipika
2017-03-01
The Centers for Medicare and Medicaid Services (CMS) canceled Meaningful Use (MU), replacing it with Advancing Care Information, which preserves many MU elements. Therefore, transitioning from MU stage 1 to MU stage 2 has important implications for the new policy, yet the quality of care provided by physicians transitioning from MU1 to MU2 is unknown. Retrospective longitudinal evaluation of the quality of care delivered by outpatient physicians at an academic medical center in the transition between MU1 and MU2. Between MU1 and MU2, 4 measures improved: hypertension control (35% vs 40%), influenza immunization (63% vs 68%), tobacco use assessment/counseling (86% vs 96%), and diabetes control (93% vs 96%; P all <.01). One worsened: senior weight screening/follow-up (54% vs 49%; P < .01). Two were unchanged: chlamydia screening and adult weight screening/follow-up. In this single-site study, when clinicians progressed from MU1 to MU2, 4 quality measures improved, 2 were unchanged, and 1 worsened. Analysis of national data should guide policy decisions about the content of MU's successor. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com
NASA Astrophysics Data System (ADS)
Curciarello, F.
We present a search for a new light vector boson, carrier of a "dark force" between WIMPs, with the KLOE detector at \\DA$\\Phi$NE. We analyzed $e^+ e^- \\to \\mu^+ \\mu^- \\gamma$ ISR events corresponding to an integrated luminosity of $239$ pb$^{-1}$ to find evidence for the $e^+ e^- \\to U\\gamma ,\\,\\, U\\to\\mu^+\\mu^-$ process. We found no $U$ vector boson signal and set a 90% CL upper limit on the ratio of the U boson and photon coupling constants between 1.6$\\times10^{-5}$ to 8.6$\\times10^{-7}$ in the mass region $520
ISOCAM observations of the Hubble Deep Field reduced with the PRETI method
NASA Astrophysics Data System (ADS)
Aussel, H.; Cesarsky, C. J.; Elbaz, D.; Starck, J. L.
1999-02-01
We have developed a new ISOCAM data reduction technique based on wavelet analysis, especially designed for the detection of faint sources in mid-infrared surveys. This method, the Pattern REcognition Technique for Isocam data (PRETI) has been used to reduce the observations of the Hubble Deep Field (HDF) and flanking fields with ISOCAM at 6.75 (LW2) and 15 mu m (LW3) (Rowan-Robinson et al. \\cite{RowanRobinson}). Simulations of ISOCAM data allow us to test the photometric accuracy and completeness of the reduction. According to these simulations, the PRETI source list is 95% complete in the 15 mu m band at 200 mu Jy and in the 6.75 mu m band at 65 mu Jy, using detection thresholds which minimize the number of false detections. We detect 49 objects in the ISO-HDF at high confidence secure level, 42 in the LW3 filter, 3 in the LW2 filter, and 4 in both filters. An additional, less secure, list of 100 sources is presented, of which 89 are detected at 15 mu m only, 7 at 6.75 mu m only and 4 in both filters. All ISO-HDF objects detected in the HDF itself have optical or infrared counterparts, except for one from the additional list. All except one of the radio sources detected in the field by Fomalont et al. (\\cite{Fomalont}) are detected with ISOCAM. Using a precise correction for the field of view distortion of ISOCAM allows us to separate blended sources. This, together with the fact that PRETI allows to correct data on the tail of cosmic rays glitches, lead us to produce deeper source lists than previous authors. Our list of bright sources agree with those of Désert et al. (\\cite{IAS}) in both filters, and with those of Goldschmidt et al. (\\cite{Goldschmidt}) in the LW3 filter, with systematic difference in photometry. Number counts derived from our results show an excess by a factor of 10 with respect to the prediction of a no evolution model (Franceschini \\cite{Franceschini98}) in the LW3 band. On the contrary, the number of sources in the LW2 band is compatible with the prediction of such a model, but with greater uncertainties, given the small number of detections. Based on observations with the Infrared Space Observatory (ISO). ISO is an ESA project with instruments funded by ESA Member States (especially the PI countries: France, Germany, The Netherlands and the United Kingdom) and with participation of ISAS and NASA.
NASA Astrophysics Data System (ADS)
Khairullina, Alphiya Y.; Oleinik, Tatiana V.
1995-01-01
Our previous works concerned with the development of methods for studying blood and action of low-intensity laser radiation on blood and erythrocyte suspensions had shown the light- scattering methods gave a large body of information on a medium studied due to the methodological relationship between irradiation processes and techniques for investigations. Detail analysis of spectral diffuse reflectivities and transmissivities of optically thick blood layers, spectral absorptivities calculated on this basis over 600 - 900 nm, by using different approximations, for a pathological state owing to hypoxia testifies to the optical significance of not only hemoglobin derivatives but also products of hemoglobin decomposition. Laser action on blood is specific and related to an initial state of blood absorption due to different composition of chromoproteids. This work gives the interpretation of spectral observations. Analysis of spectral dependencies of the exinction coefficient e, mean cosine m of phase function, and parameter Q equals (epsilon) (1-(mu) )H/(lambda) (H - hematocrit) testifies to decreasing the relative index of refraction of erythrocytes and to morphological changes during laser action under pathology owing to hypoxia. The possibility to obtain physical and chemical information on the state of blood under laser action in vivo is shown to be based on the method proposed by us for calculating multilayered structures modeling human organs and on the technical implementation of this method.
Marchevsky, M.; Ambrosio, G.; Lamm, M.; ...
2016-02-12
Acoustic emission (AE) detection is a noninvasive technique allowing the localization of the mechanical events and quenches in superconducting magnets. Application of the AE technique is especially advantageous in situations where magnet integrity can be jeopardized by the use of voltage taps or inductive pickup coils. As the prototype module of the transport solenoid (TS) for the Mu2e experiment at Fermilab represents such a special case, we have developed a dedicated six-channel AE detection system and accompanying software aimed at localizing mechanical events during the coil cold testing. The AE sensors based on transversely polarized piezoceramic washers combined with cryogenicmore » preamplifiers were mounted at the outer surface of the solenoid aluminum shell, with a 60° angular step around the circumference. Acoustic signals were simultaneously acquired at a rate of 500 kS/s, prefiltered and sorted based on their arrival time. Next, based on the arrival timing, angular and axial coordinates of the AE sources within the magnet structure were calculated. Furthermore, we present AE measurement results obtained during cooldown, spot heater firing, and spontaneous quenching of the Mu2e TS module prototype and discuss their relevance for mechanical stability assessment and quench localization.« less
Possible explanation of the solar-neutrino puzzle
NASA Technical Reports Server (NTRS)
Bethe, H. A.
1986-01-01
A new derivation of the Mikheyev and Smirnov (1985) mechanism for the conversion of electron neutrinos into mu neutrinos when traversing the sun is presented, and various hypotheses set forth. It is assumed that this process is responsible for the detection of fewer solar neutrinos than expected, with neutrinos below a minimum energy, E(m), being undetectable. E(m) is found to be about 6 MeV, and the difference of the squares of the respective neutrino masses is calculated to be 6 X 10 to the - 5th sq eV. A restriction on the neutrino mixing angle is assumed such that the change of density near the crossing point is adiabatic. It is predicted that no resonance conversion of neutrinos will occur in the dense core of supernovae, but conversion of electron neutrinos to mu neutrinos will occur as they escape outward through a density region around 100.
Percolation technique for galaxy clustering
NASA Technical Reports Server (NTRS)
Klypin, Anatoly; Shandarin, Sergei F.
1993-01-01
We study percolation in mass and galaxy distributions obtained in 3D simulations of the CDM, C + HDM, and the power law (n = -1) models in the Omega = 1 universe. Percolation statistics is used here as a quantitative measure of the degree to which a mass or galaxy distribution is of a filamentary or cellular type. The very fast code used calculates the statistics of clusters along with the direct detection of percolation. We found that the two parameters mu(infinity), characterizing the size of the largest cluster, and mu-squared, characterizing the weighted mean size of all clusters excluding the largest one, are extremely useful for evaluating the percolation threshold. An advantage of using these parameters is their low sensitivity to boundary effects. We show that both the CDM and the C + HDM models are extremely filamentary both in mass and galaxy distribution. The percolation thresholds for the mass distributions are determined.
"Vibrational bonding": a new type of chemical bond is discovered.
Rhodes, Christopher J; Macrae, Roderick M
2015-01-01
A long-sought but elusive new type of chemical bond, occurring on a minimum-free, purely repulsive potential energy surface, has recently been convincingly shown to be possible on the basis of high-level quantum-chemical calculations. This type of bond, termed a vibrational bond, forms because the total energy, including the dynamical energy of the nuclei, is lower than the total energy of the dissociated products, including their vibrational zero-point energy. For this to be the case, the ZPE of the product molecule must be very high, which is ensured by replacing a conventional hydrogen atom with its light isotope muonium (Mu, mass = 1/9 u) in the system Br-H-Br, a natural transition state in the reaction between Br and HBr. A paramagnetic species observed in the reaction Mu +Br2 has been proposed as a first experimental sighting of this species, but definitive identification remains challenging.
Measurement of natural radionuclides in U.K. diet.
Smith-Briggs, J L; Bradley, E J
1984-05-01
The levels of radium-226, lead-210 and polonium-210 in the U.K. diet have been determined. The important food groups contributing to the intake of these radionuclides have been identified. Seventy-five percent of the daily intake of radium-226 is derived from beverages, cereals, other vegetables, bread, sugars and preserves. Seventy-five percent of the intake of lead-210 and polonium-210 is derived from bread, milk, cereals, beverages, other vegetables, sugars and preserves, and meat products. The average daily intakes of these radionuclides are tentatively calculated to be 30 mBq for radium-226 and 82 mBq for both lead-210 and polonium-210. These levels are compared with data from other countries. The annual effective dose equivalents resulting from the intakes are approximately 3 muSv for radium-226 and 54 muSv from lead-210 and polonium-210 together. The differences between these doses and other current estimates are discussed.
Computational prediction of muon stopping sites using ab initio random structure searching (AIRSS)
NASA Astrophysics Data System (ADS)
Liborio, Leandro; Sturniolo, Simone; Jochym, Dominik
2018-04-01
The stopping site of the muon in a muon-spin relaxation experiment is in general unknown. There are some techniques that can be used to guess the muon stopping site, but they often rely on approximations and are not generally applicable to all cases. In this work, we propose a purely theoretical method to predict muon stopping sites in crystalline materials from first principles. The method is based on a combination of ab initio calculations, random structure searching, and machine learning, and it has successfully predicted the MuT and MuBC stopping sites of muonium in Si, diamond, and Ge, as well as the muonium stopping site in LiF, without any recourse to experimental results. The method makes use of Soprano, a Python library developed to aid ab initio computational crystallography, that was publicly released and contains all the software tools necessary to reproduce our analysis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurnaz, Asli; Kuecuekoemeroglu, B.; Okumusoglu, N. T.
In this study, it was determined environmental gamma radiation dose rate for some counties of Trabzon-Turkey. A detailed ambient gamma dose measurement has been performed in the seven counties of Trabzon, using a portable environmental survey meter (NaI detector, INSPECTOR 1000). The measurements were performed indoor and outdoor of buildings and also at each spot, a reading was taken at 1 m above ground level. The dose rates varied from 42.69 nGy/h and 140.91 nGy/h for indoor gamma dose and 27.84 nGy/h and 121.80 nGy/h for outdoor gamma dose . Average indoor and outdoor gamma dose rates were ascertained tomore » be 71.05 nGy/h and 60.20 nGy/h, respectively. The annual effective doses were calculated from indoor and outdoor gamma doses to be 348.56 muSv/y and 73.83 muSv/y, respectively.« less
Chai, Jianfang; Zhu, Hongping; Stückl, A Claudia; Roesky, Herbert W; Magull, Jörg; Bencini, Alessandro; Caneschi, Andrea; Gatteschi, Dante
2005-06-29
This paper reports on the synthesis, X-ray structure, magnetic properties, and DFT calculations of [[HC(CMeNAr)2]Mn]2 (Ar = 2,6-iPr2C6H3) (2), the first complex with three-coordinate manganese(I). Reduction of the iodide [[HC(CMeNAr)2]Mn(mu-I)]2 (1) with Na/K in toluene afforded 2 as dark-red crystals. The molecule of 2 contains a Mn2(2+) core with a Mn-Mn bond. The magnetic investigations show a rare example of a high-spin manganese(I) complex with an antiferromagnetic interaction between the two Mn(I) centers. The DFT calculations indicate a strong s-s interaction of the two Mn(I) ions with the open shell configuration (3d54s1). This suggests that the magnetic behavior of 2 could be correctly described as the coupling between two S1 = S2 = 5/2 spin centers. The Mn-Mn bond energy is estimated at 44 kcal mol(-1) by first principle calculations with the B3LYP functional. The further oxidative reaction of 2 with KMnO4 or O2 resulted in the formation of manganese(III) oxide [[HC(CMeNAr)2]Mn(mu-O)]2 (3). Compound 3 shows an antiferromagnetic coupling between the two oxo-bridged manganese(III) centers by magnetic measurements.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sago, Norichika; Barack, Leor; Detweiler, Steven
2008-12-15
Recently, two independent calculations have been presented of finite-mass ('self-force') effects on the orbit of a point mass around a Schwarzschild black hole. While both computations are based on the standard mode-sum method, they differ in several technical aspects, which makes comparison between their results difficult--but also interesting. Barack and Sago [Phys. Rev. D 75, 064021 (2007)] invoke the notion of a self-accelerated motion in a background spacetime, and perform a direct calculation of the local self-force in the Lorenz gauge (using numerical evolution of the perturbation equations in the time domain); Detweiler [Phys. Rev. D 77, 124026 (2008)] describesmore » the motion in terms a geodesic orbit of a (smooth) perturbed spacetime, and calculates the metric perturbation in the Regge-Wheeler gauge (using frequency-domain numerical analysis). Here we establish a formal correspondence between the two analyses, and demonstrate the consistency of their numerical results. Specifically, we compare the value of the conservative O({mu}) shift in u{sup t} (where {mu} is the particle's mass and u{sup t} is the Schwarzschild t component of the particle's four-velocity), suitably mapped between the two orbital descriptions and adjusted for gauge. We find that the two analyses yield the same value for this shift within mere fractional differences of {approx}10{sup -5}-10{sup -7} (depending on the orbital radius)--comparable with the estimated numerical error.« less
Hart, Bryan E; Lee, Sunhee
2016-12-01
Buruli ulcer (BU) vaccine design faces similar challenges to those observed during development of prophylactic tuberculosis treatments. Multiple BU vaccine candidates, based upon Mycobacterium bovis BCG, altered Mycobacterium ulcerans (MU) cells, recombinant MU DNA, or MU protein prime-boosts, have shown promise by conferring transient protection to mice against the pathology of MU challenge. Recently, we have shown that a recombinant BCG vaccine expressing MU-Ag85A (BCG MU-Ag85A) displayed the highest level of protection to date, by significantly extending the survival time of MU challenged mice compared to BCG vaccination alone. Here we describe the generation, immunogenicity testing, and evaluation of protection conferred by a recombinant BCG strain which overexpresses a fusion of two alternative MU antigens, Ag85B and the MU ortholog of tuberculosis TB10.4, EsxH. Vaccination with BCG MU-Ag85B-EsxH induces proliferation of Ag85 specific CD4+ T cells in greater numbers than BCG or BCG MU-Ag85A and produces IFNγ+ splenocytes responsive to whole MU and recombinant antigens. In addition, anti-Ag85A and Ag85B IgG humoral responses are significantly enhanced after administration of the fusion vaccine compared to BCG or BCG MU-Ag85A. Finally, mice challenged with MU following a single subcutaneous vaccination with BCG MU-Ag85B-EsxH display significantly less bacterial burden at 6 and 12 weeks post-infection, reduced histopathological tissue damage, and significantly longer survival times compared to vaccination with either BCG or BCG MU-Ag85A. These results further support the potential of BCG as a foundation for BU vaccine design, whereby discovery and recombinant expression of novel immunogenic antigens could lead to greater anti-MU efficacy using this highly safe and ubiquitous vaccine.
Héroux, Martin E; Brown, Harrison J; Inglis, J Timothy; Siegmund, Gunter P; Blouin, Jean-Sébastien
2015-08-15
Human medial gastrocnemius (MG) motor units (MUs) are thought to occupy small muscle territories or regions, with low-threshold units preferentially located distally. We used intramuscular recordings to measure the territory of muscle fibres from MG MUs and determine whether these MUs are grouped by recruitment threshold or joint action (ankle plantar flexion and knee flexion). The territory of MUs from the MG muscle varied from somewhat localized to highly distributed, with approximately half the MUs spanning at least half the length and width of the muscle. There was also no evidence of regional muscle activity based on MU recruitment thresholds or joint action. The CNS does not have the means to selectively activate regions of the MG muscle based on task requirements. Human medial gastrocnemius (MG) motor units (MUs) are thought to occupy small muscle territories, with low-threshold units preferentially located distally. In this study, subjects (n = 8) performed ramped and sustained isometric contractions (ankle plantar flexion and knee flexion; range: ∼1-40% maximal voluntary contraction) and we measured MU territory size with spike-triggered averages from fine-wire electrodes inserted along the length (seven electrodes) or across the width (five electrodes) of the MG muscle. Of 69 MUs identified along the length of the muscle, 32 spanned at least half the muscle length (≥ 6.9 cm), 11 of which spanned all recording sites (13.6-17.9 cm). Distal fibres had smaller pennation angles (P < 0.05), which were accompanied by larger territories in MUs with fibres located distally (P < 0.05). There was no distal-to-proximal pattern of muscle activation in ramp contraction (P = 0.93). Of 36 MUs identified across the width of the muscle, 24 spanned at least half the muscle width (≥ 4.0 cm), 13 of which spanned all recording sites (8.0-10.8 cm). MUs were not localized (length or width) based on recruitment threshold or contraction type, nor was there a relationship between MU territory size and recruitment threshold (Spearman's rho = -0.20 and 0.13, P > 0.18). MUs in the human MG have larger territories than previously reported and are not localized based on recruitment threshold or joint action. This indicates that the CNS does not have the means to selectively activate regions of the MG muscle based on task requirements. © 2015 The Authors. The Journal of Physiology © 2015 The Physiological Society.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Götstedt, Julia; Karlsson Hauer, Anna; Bäck, Anna, E-mail: anna.back@vgregion.se
Purpose: Complexity metrics have been suggested as a complement to measurement-based quality assurance for intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT). However, these metrics have not yet been sufficiently validated. This study develops and evaluates new aperture-based complexity metrics in the context of static multileaf collimator (MLC) openings and compares them to previously published metrics. Methods: This study develops the converted aperture metric and the edge area metric. The converted aperture metric is based on small and irregular parts within the MLC opening that are quantified as measured distances between MLC leaves. The edge area metricmore » is based on the relative size of the region around the edges defined by the MLC. Another metric suggested in this study is the circumference/area ratio. Earlier defined aperture-based complexity metrics—the modulation complexity score, the edge metric, the ratio monitor units (MU)/Gy, the aperture area, and the aperture irregularity—are compared to the newly proposed metrics. A set of small and irregular static MLC openings are created which simulate individual IMRT/VMAT control points of various complexities. These are measured with both an amorphous silicon electronic portal imaging device and EBT3 film. The differences between calculated and measured dose distributions are evaluated using a pixel-by-pixel comparison with two global dose difference criteria of 3% and 5%. The extent of the dose differences, expressed in terms of pass rate, is used as a measure of the complexity of the MLC openings and used for the evaluation of the metrics compared in this study. The different complexity scores are calculated for each created static MLC opening. The correlation between the calculated complexity scores and the extent of the dose differences (pass rate) are analyzed in scatter plots and using Pearson’s r-values. Results: The complexity scores calculated by the edge area metric, converted aperture metric, circumference/area ratio, edge metric, and MU/Gy ratio show good linear correlation to the complexity of the MLC openings, expressed as the 5% dose difference pass rate, with Pearson’s r-values of −0.94, −0.88, −0.84, −0.89, and −0.82, respectively. The overall trends for the 3% and 5% dose difference evaluations are similar. Conclusions: New complexity metrics are developed. The calculated scores correlate to the complexity of the created static MLC openings. The complexity of the MLC opening is dependent on the penumbra region relative to the area of the opening. The aperture-based complexity metrics that combined either the distances between the MLC leaves or the MLC opening circumference with the aperture area show the best correlation with the complexity of the static MLC openings.« less
Bobadova-Parvanova, Petia; Wang, Qingfang; Quinonero-Santiago, David; Morokuma, Keiji; Musaev, Djamaladdin G
2006-09-06
The mechanisms of dinitrogen hydrogenation by two different complexes--[(eta(5)-C(5)Me(4)H)(2)Zr](2)(mu(2),eta(2),eta(2)-N(2)), synthesized by Chirik and co-workers [Nature 2004, 427, 527], and {[P(2)N(2)]Zr}(2)(mu(2),eta(2),eta(2)-N(2)), where P(2)N(2) = PhP(CH(2)SiMe(2)NSiMe(2)CH(2))(2)PPh, synthesized by Fryzuk and co-workers [Science 1997, 275, 1445]--are compared with density functional theory calculations. The former complex is experimentally known to be capable of adding more than one H(2) molecule to the side-on coordinated N(2) molecule, while the latter does not add more than one H(2). We have shown that the observed difference in the reactivity of these dizirconium complexes is caused by the fact that the former ligand environment is more rigid than the latter. As a result, the addition of the first H(2) molecule leads to two different products: a non-H-bridged intermediate for the Chirik-type complex and a H-bridged intermediate for the Fryzuk-type complex. The non-H-bridged intermediate requires a smaller energy barrier for the second H(2) addition than the H-bridged intermediate. We have also examined the effect of different numbers of methyl substituents in [(eta(5)-C(5)Me(n)H(5)(-)(n))(2)Zr](2)(mu(2),eta(2),eta(2)-N(2)) for n = 0, 4, and 5 (n = 5 is hypothetical) and [(eta(5)-C(5)H(2)-1,2,4-Me(3))(eta(5)-C(5)Me(5))(2)Zr](2)(mu(2),eta(2),eta(2)-N(2)) and have shown that all complexes of this type would follow a similar H(2) addition mechanism. We have also performed an extensive analysis on the factors (side-on coordination of N(2) to two Zr centers, availability of the frontier orbitals with appropriate symmetry, and inflexibility of the catalyst ligand environment) that are required for successful hydrogenation of the coordinated dinitrogen.
Search for $$ {\\text{B}}_{\\text{s}}^0 $$ → μ + μ - and B0 → μ + μ - decays
Chatrchyan, S.; Khachatryan, V.; Sirunyan, A. M.; ...
2012-04-06
A search for the rare decays B_s to mu+ mu- and B^0 to mu^+ mu^- is performed in pp collisions at sqrt(s) = 7 TeV, with a data sample corresponding to an integrated luminosity of 5 inverse femtobarns collected by the CMS experiment at the LHC. In both decays, the number of events observed after all selection requirements is consistent with the expectation from background plus standard model signal predictions. The resulting upper limits on the branching fractions are Br(B_s to mu^+ mu^-) < 7.7E-9 and Br(B^0 to mu^+ mu^-) < 1.8E-9 at 95% confidence level.
Hughes, Michael J; Mercier, Hélène P A; Schrobilgen, Gary J
2010-01-04
The salt, [OsO(2)F(3)][Sb(2)F(11)], has been synthesized by dissolution of cis-OsO(2)F(4) in liquid SbF(5), followed by removal of excess SbF(5) at 0 degrees C to yield orange, crystalline [OsO(2)F(3)][Sb(2)F(11)]. The X-ray crystal structure (-173 degrees C) consists of an OsO(2)F(3)(+) cation fluorine bridged to an Sb(2)F(11)(-) anion. The light atoms of OsO(2)F(3)(+) and the bridging fluorine atom form a distorted octahedron around osmium in which the osmium atom is displaced from its center toward an oxygen atom and away from the trans-fluorine bridge atom. As in other transition metal dioxofluorides, the oxygen ligands are cis to one another and the fluorine bridge atom is trans to an oxygen ligand and cis to the remaining oxygen ligand. The Raman spectrum (-150 degrees C) of solid [OsO(2)F(3)][Sb(2)F(11)] was assigned on the basis of the ion pair observed in the low-temperature crystal structure. Under dynamic vacuum, [OsO(2)F(3)][Sb(2)F(11)] loses SbF(5), yielding the known [mu-F(OsO(2)F(3))(2)][Sb(2)F(11)] salt with no evidence for [OsO(2)F(3)][SbF(6)] formation. Attempts to synthesize [OsO(2)F(3)][SbF(6)] by the reaction of [OsO(2)F(3)][Sb(2)F(11)] with an equimolar amount of cis-OsO(2)F(4) or by a 1:1 stoichiometric reaction of cis-OsO(2)F(4) with SbF(5) in anhydrous HF yielded only [mu-F(OsO(2)F(3))(2)][Sb(2)F(11)]. Quantum-chemical calculations at the SVWN and B3LYP levels of theory and natural bond orbital analyses were used to calculate the gas-phase geometries, vibrational frequencies, natural population analysis charges, bond orders, and valencies of OsO(2)F(3)(+), [OsO(2)F(3)][Sb(2)F(11)], [OsO(2)F(3)][SbF(6)], and Sb(2)F(11)(-). The relative thermochemical stabilities of [OsO(2)F(3)][SbF(6)], [OsO(2)F(3)][Sb(2)F(11)], [OsO(2)F(3)][AsF(6)], [mu-F(OsO(2)F(3))(2)][SbF(6)], [mu-F(OsO(2)F(3))(2)][Sb(2)F(11)], and [mu-F(OsO(2)F(3))(2)][AsF(6)] were assessed using the appropriate Born-Haber cycles to account for the preference for [mu-F(OsO(2)F(3))(2)][Sb(2)F(11)] formation over [OsO(2)F(3)][SbF(6)] formation and for the inability to synthesize [OsO(2)F(3)][SbF(6)].
Retrofitting and the mu Problem
DOE Office of Scientific and Technical Information (OSTI.GOV)
Green, Daniel; Weigand, Timo; /SLAC /Stanford U., Phys. Dept.
2010-08-26
One of the challenges of supersymmetry (SUSY) breaking and mediation is generating a {mu} term consistent with the requirements of electro-weak symmetry breaking. The most common approach to the problem is to generate the {mu} term through a SUSY breaking F-term. Often these models produce unacceptably large B{mu} terms as a result. We will present an alternate approach, where the {mu} term is generated directly by non-perturtative effects. The same non-perturbative effect will also retrofit the model of SUSY breaking in such a way that {mu} is at the same scale as masses of the Standard Model superpartners. Because themore » {mu} term is not directly generated by SUSY breaking effects, there is no associated B{mu} problem. These results are demonstrated in a toy model where a stringy instanton generates {mu}.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hallerman, G.; Gray, R.J.
An instrument for crushing-strength determinations of uncoated and pyrolytic-carbon-coated fuel particles (50 to 500 mu in diameter) was developed to relate the crushing strength of the particles to their fabricability. The instrument consists of a loading mechanism, load cell, and a power supply-readout unit. The information that can be obtained by statistical methods of the data analysis is illustrated by results on two batches of fuel particles. (auth)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haynes, Erin N., E-mail: Erin.Haynes@uc.edu; Chen, Aimin, E-mail: Aimin.Chen@uc.edu; Ryan, Patrick, E-mail: Patrick.Ryan@uc.edu
Antisocial behavior is a product of multiple interacting sociohereditary variables, yet there is increasing evidence that metal exposure, particularly, manganese and lead, play a role in its epigenesis. Other metals, such as arsenic, cadmium, chromium, and mercury, and exposure to traffic-related air pollution, such as fine particulate matter ({<=}2.5 {mu}m) have been associated with neurological deficits, yet largely unexplored with respect to their relationship with delinquent behavior. The purpose of this study is to evaluate the ecological relationship between county-wide reported airborne emissions of air metals, particulate matter, and youth adjudicated for criminal activity. Metal exposure data were collected frommore » the Environmental Protection Agency AirData. Population statistics were obtained from the United States Census 2000 and adjudication data was obtained from the Courts of Common Pleases from each Ohio County. Simple correlations were calculated with the percentage of adjudications, all covariates, and estimated metal air emissions. Separate negative binomial regression models for each pollutant were used to provide an estimated risk ratio of pollutant emissions on the risk of adjudication for all Ohio counties adjusting for urban-rural residence, percentage of African Americans, median family income, percentage of family below poverty, percentage of high school graduation in 25 years and older populations, and population density. Metal emissions and PM in 1999 were all correlated with adjudication rate (2003-2005 average). Metal emissions were associated with slightly higher risk of adjudication, with about 3-4% increased risk per natural log unit of metal emission except chromium. The associations achieved statistical significance for manganese and mercury. The particulate matter {<=}2.5 and {<=}10 {mu}m emissions had a higher risk estimate, with 12% and 19% increase per natural log unit emission, respectively, and also achieved statistical significance. In summary, airborne exposure to manganese, mercury, and particulate matter are associated with increased risk of adjudication. Causality cannot be proven in observational studies such as this one, but the association warrants further examination in other research studies. Comprehensive epidemiologic investigations of metal exposure in pediatric populations should include social health outcomes, including measures of delinquent or criminal activity. Furthermore, the influence of metals on the neurotoxic pathway leading to delinquent activity should be further explored. - Highlights: Black-Right-Pointing-Pointer We evaluate the relationship between air pollutants and adjudication. Black-Right-Pointing-Pointer Manganese, mercury, and particulate matter are associated with risk of adjudication. Black-Right-Pointing-Pointer Further research of metal exposure should include social health outcomes.« less
cDNA sequences and organization of IgM heavy chain genes in two holostean fish.
Wilson, M R; van Ravenstein, E; Miller, N W; Clem, L W; Middleton, D L; Warr, G W
1995-01-01
Immunoglobulin M heavy chain (mu) sequences of two holostean fish, the bowfin, Amia calva, and the longnose gar, Lepisosteus osseus, were amplified from spleen mRNA by RACE-PCR, cloned, and sequenced. Each mu chain showed the conserved four constant domain structure typical of a secreted mu chain. Southern blot analyses with specific heavy chain variable (VH) and constant (CH) region probes suggest that both fish possess an IgH locus that resembles that of the teleosts, amphibians, and mammals in its organization. The overall sequence similarity of gar and bowfin mu chains was 60% and 48% at the nucleotide and amino acid levels, respectively, while similarity to the mu chains of teleosts and elasmobranchs was lower. The bowfin mu chain possesses a distinctive proline-rich sequence at the C mu 1/C mu 2 boundary; a shorter proline-rich sequence is present at this position in the gar mu chain. Both gar and bowfin show, in their C mu 4 sequences, motifs that could serve as cryptic splice donor sites for the production of mRNA encoding the membrane-bound form of the mu chains, and the bowfin also shows a potential cryptic splice donor site in the C mu 3 exon.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rothman, R.B.; Jacobson, A.E.; Rice, K.C.
1987-11-01
Previous studies demonstrated that pretreatment of brain membranes with the irreversible mu antagonist, beta-funaltrexamine (beta-FNA), partially eliminated mu binding sites (25,35), consistent with the existence of two mu binding sites distinguished by beta-FNA. This paper tests the hypothesis that the FNA-sensitive and FNA-insensitive mu binding sites have different anatomical distributions in rat brain. Prior to autoradiographic visualization of mu binding sites, (/sup 3/H)oxymorphone, (/sup 3/H)D-ala2-MePhe4, Gly-ol5-enkephalin (DAGO), and (/sup 125/I)D-ala2-Me-Phe4-met(o)-ol)enkephalin (FK33824) were shown to selectively label mu binding sites using slide mounted sections of molded minced rat brain. As found using membranes, beta-FNA eliminated only a portion of mu bindingmore » sites. Autoradiographic visualization of mu binding sites using the mu-selective ligand (/sup 125/I)FK33824 in control and FNA-treated sections of rat brain demonstrated that the proportion of mu binding sites sensitive to beta-FNA varied across regions of the brain, particularly the dorsal thalamus, ventrobasal complex and the hypothalamus, providing anatomical data supporting the existence of two classes of mu binding sites in rat brain.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gallagher, Carolyn M., E-mail: 2crgallagher@optonline.net; Chen, John J.; Kovach, John S.
Background: Cadmium is a ubiquitous environmental pollutant associated with increased risk of leading causes of mortality and morbidity in women, including breast cancer and osteoporosis. Iron deficiency increases absorption of dietary cadmium, rendering women, who tend to have lower iron stores than men, more susceptible to cadmium uptake. We used body iron, a measure that incorporates both serum ferritin and soluble transferrin receptor, as recommended by the World Health Organization, to evaluate the relationships between iron status and urine and blood cadmium. Methods: Serum ferritin, soluble transferrin receptor, urine and blood cadmium values in never-smoking, non-pregnant, non-lactating, non-menopausal women agedmore » 20-49 years (n=599) were obtained from the 2003-2008 National Health and Nutrition Examination Surveys. Body iron was calculated from serum ferritin and soluble transferrin receptor, and iron deficiency defined as body iron <0 mg/kg. Robust linear regression was used to evaluate the relationships between body iron and blood and urine cadmium, adjusted for age, race, poverty, body mass index, and parity. Results: Per incremental (mg/kg) increase in body iron, urine cadmium decreased by 0.003 {mu}g/g creatinine and blood cadmium decreased by 0.014 {mu}g/L. Iron deficiency was associated with 0.044 {mu}g/g creatinine greater urine cadmium (95% CI=0.020, 0.069) and 0.162 {mu}g/L greater blood cadmium (95% CI=0.132, 0.193). Conclusions: Iron deficiency is a risk factor for increased blood and urine cadmium among never-smoking, pre-menopausal, non-pregnant US women, independent of age, race, poverty, body mass index and parity. Expanding programs to detect and correct iron deficiency among non-pregnant women merits consideration as a potential means to reduce the risk of cadmium associated diseases. - Highlights: {yields} Body iron was calculated from serum ferritin and soluble transferrin receptor. {yields} Body iron was inversely associated with blood and urine cadmium in US women. {yields} Inverse associations with blood cadmium were evident in all race/ethnic subsamples. {yields} Inverse associations with urine cadmium were evident in women of other/multi-race. {yields} Black women had lower mean body iron compared to white women.« less
Waggoner, B T; Marrs, C F; Howe, M M; Pato, M L
1984-07-15
The regions of bacteriophage Mu involved in host cell killing were determined by infection of a lambda-immune host with 12 lambda pMu-transducing phages carrying different amounts of Mu DNA beginning at the left end. Infecting lambda pMu phages containing 5.0 (+/- 0.2) kb or less of the left end of Mu DNA did not kill the lambda-immune host, whereas lambda pMu containing 5.1 kb did kill, thus locating the right end of the kil gene between approximately 5.0 and 5.1 kb. For the Kil+ phages the extent of killing increased as the multiplicity of infection (m.o.i.) increased. In addition, killing was also affected by the presence of at least two other regions of Mu DNA: one, located between 5.1 and 5.8 kb, decreased the extent of killing; the other, located between 6.3 and 7.9 kb, greatly increased host cell killing. Killing was also assayed after lambda pMu infection of a lambda-immune host carrying a mini-Mu deleted for most of the B gene and the middle region of Mu DNA. Complementation of mini-Mu replication by infecting B+ lambda pMu phages resulted in killing of the lambda-immune, mini-Mu-containing host, regardless of the presence or absence of the Mu kil gene. The extent of host cell killing increased as the m.o.i. of the infecting lambda pMu increased, and was further enhanced by both the presence of the kil gene and the region located between 6.3 and 7.9 kb. These distinct processes of kil-mediated killing in the absence of replication and non-kil-mediated killing in the presence of replication were also observed after induction of replication-deficient and kil mutant prophages, respectively.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chappard, Christine; Basillais, Armelle; Benhamou, Laurent
Microcomputed tomography ({mu}CT) produces three-dimensional (3D) images of trabecular bone. We compared conventional {mu}CT (C{mu}CT) with a polychromatic x-ray cone beam to synchrotron radiation (SR) {mu}CT with a monochromatic parallel beam for assessing trabecular bone microarchitecture of 14 subchondral femoral head specimens from patients with osteoarthritis (n=10) or osteoporosis (n=4). SR{mu}CT images with a voxel size of 10.13 {mu}m were reconstructed from 900 2D radiographic projections (angular step, 0.2 deg. ). C{mu}CT images with a voxel size of 10.77 {mu}m were reconstructed from 205, 413, and 825 projections obtained using angular steps of 0.9 deg., 0.45 deg., and 0.23 deg.,more » respectively. A single threshold was used to binarize the images. We computed bone volume/tissue volume (BV/TV), bone surface/bone volume (BS/BV), trabecular number (Tb.N), trabecular thickness (Tb.Th and Tb.Th*), trabecular spacing (Tb.Sp), degree of anisotropy (DA), and Euler density. With the 0.9 deg. angular step, all C{mu}CT values were significantly different from SR{mu}CT values. With the 0.23 deg. and 0.45 deg. rotation steps, BV/TV, Tb.Th, and BS/BV by C{mu}CT differed significantly from the values by SR{mu}CT. The error due to slice matching (visual site matching {+-}10 slices) was within 1% for most parameters. Compared to SR{mu}CT, BV/TV, Tb.Sp, and Tb.Th by C{mu}CT were underestimated, whereas Tb.N and Tb.Th* were overestimated. A Bland and Altman plot showed no bias for Tb.N or DA. Bias was -0.8{+-}1.0%, +5.0{+-}1.1 {mu}m, -5.9{+-}6.3 {mu}m, and -5.7{+-}29.1 {mu}m for BV/TV, Tb.Th*, Tb.Th, and Tb.Sp, respectively, and the differences did not vary over the range of values. Although systematic differences were noted between SR{mu}CT and C{mu}CT values, correlations between the techniques were high and the differences would probably not change the discrimination between study groups. C{mu}CT provides a reliable 3D assessment of human defatted bone when working at the 0.23 deg. or 0.45 deg. rotation step; the 0.9 deg. rotation step may be insufficiently accurate for morphological bone analysis.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aaltonen, T.; Maki, T.; Mehtala, P.
2009-02-01
This article presents the first measurement of the ratio of branching fractions B({lambda}{sub b}{sup 0}{yields}{lambda}{sub c}{sup +}{mu}{sup -}{nu}{sub {mu}})/B({lambda}{sub b}{sup 0}{yields}{lambda}{sub c}{sup +}{pi}{sup -}). Measurements in two control samples using the same technique B(B{sup 0}{yields}D{sup +}{mu}{sup -}{nu}{sub {mu}})/B(B{sup 0}{yields}D{sup +}{pi}{sup -}) and B(B{sup 0}{yields}D*(2010){sup +}{mu}{sup -}{nu}{sub {mu}})/B(B{sup 0}{yields}D*(2010){sup +}{pi}{sup -}) are also reported. The analysis uses data from an integrated luminosity of approximately 172 pb{sup -1} of pp collisions at {radical}(s)=1.96 TeV, collected with the CDF II detector at the Fermilab Tevatron. The relative branching fractions are measured to be (B({lambda}{sub b}{sup 0}{yields}{lambda}{sub c}{sup +}{mu}{sup -}{nu}{sub {mu}})/B({lambda}{sub b}{sup 0}{yields}{lambda}{sub c}{supmore » +}{pi}{sup -}))=16.6{+-}3.0(stat){+-}1.0(syst)(+2.6/-3.4)(PDG){+-}0.3 (EBR), (B(B{sup 0}{yields}D{sup +}{mu}{sup -}{nu}{sub {mu}})/B(B{sup 0}{yields}D{sup +}{pi}{sup -}))9.9{+-}1.0(stat){+-}0.6(syst){+-}0.4(PDG){+-}0.5(EBR), and (B(B{sup 0}{yields}D*(2010){sup +}{mu}{sup -}{nu}{sub {mu}})/B(B{sup 0}{yields}D*(2010){sup +}{pi}{sup -}))=16.5{+-}2.3(stat){+-} 0.6(syst){+-}0.5(PDG){+-}0.8(EBR). The uncertainties are from statistics (stat), internal systematics (syst), world averages of measurements published by the Particle Data Group or subsidiary measurements in this analysis (PDG), and unmeasured branching fractions estimated from theory (EBR), respectively. This article also presents measurements of the branching fractions of four new {lambda}{sub b}{sup 0} semileptonic decays: {lambda}{sub b}{sup 0}{yields}{lambda}{sub c}(2595){sup +}{mu}{sup -}{nu}{sub {mu}}, {lambda}{sub b}{sup 0}{yields}{lambda}{sub c}(2625){sup +}{mu}{sup -}{nu}{sub {mu}}, {lambda}{sub b}{sup 0}{yields}{sigma}{sub c}(2455){sup 0}{pi}{sup +}{mu}{sup -}{nu}{sub {mu}}, and {lambda}{sub b}{sup 0}{yields}{sigma}{sub c}(2455){sup ++}{pi}{sup -}{mu}{sup -}{nu}{sub {mu}}, relative to the branching fraction of the {lambda}{sub b}{sup 0}{yields}{lambda}{sub c}{sup +}{mu}{sup -}{nu}{sub {mu}} decay. Finally, the transverse-momentum distribution of {lambda}{sub b}{sup 0} baryons produced in pp collisions is measured and found to be significantly different from that of B{sup 0} mesons, which results in a modification in the production cross-section ratio {sigma}{sub {lambda}{sub b}{sup 0}}/{sigma}{sub B{sup 0}} with respect to the CDF I measurement.« less
Density functional theory studies of oxygen and carbonate binding to a dicopper patellamide complex.
Latifi, Reza; Bagherzadeh, Mojtaba; Milne, Bruce F; Jaspars, Marcel; de Visser, Sam P
2008-12-01
In this work we present results of density functional theory (DFT) calculations on dicopper patellamides and their affinity for molecular oxygen and carbonate. Patellamides are cyclic octapeptides that are produced by a cyanobacterium, and may show promise as therapeutics. Thus, carbonate binding to a dicopper patellamide center gives a stable cyclic octapeptide with a twist of almost 90 degrees . The system exists in close-lying open-shell singlet and triplet spin states with two unpaired electrons in orthogonal sigma* orbitals on each metal center. Subsequently, we replaced carbonate with dioxygen and found a stable Cu2(mu-O)2 diamond shaped patellamide core. In this structure the original dioxygen bond is significantly weakened to essentially a single bond, which should enable the system to transfer these oxygen atoms to substrates. We predicted the IR and Raman spectra of the Cu2(mu-O)2 diamond shaped patellamide structure using density functional theory and found a considerable isotope effect on the O-O stretch vibration for 16O2 versus 18O2 bound structures. Our studies reveal that carbonate forms an extremely stable complex with dicopper patellamide, but that additional molecular oxygen to this system does not give a potential oxidant. Therefore, it is more likely that carbonate prepares the system for dioxygen binding by folding it into the correct configuration followed in the proposed catalytic cycle by a protonation event preceding dioxygen binding to enable the system to reorganize to form a stable Cu2(mu-O)2-patellamide cluster. Alternatively, carbonate may act as an inhibitor that blocks the catalytic activity of the system. It is anticipated that the Cu2(mu-O)2-patellamide structure is a potential active oxidant of the dicopper patellamide complex.
Koo, Chi-Kin; Wong, Ka-Leung; Lau, Kai-Cheung; Wong, Wai-Yeung; Lam, Michael Hon-Wah
2009-08-03
The bis(diphenylphosphino)methane (dppm)-bridged dinuclear cycloplatinated complex {[Pt(L)](2)(mu-dppm)}(2+) (Pt(2)dppm; HL: 2-phenyl-6-(1H-pyrazol-3-yl)-pyridine) demonstrates interesting reversible "pivot-hinge"-like intramolecular motions in response to the protonation/deprotonation of L. In its protonated "closed" configuration, the two platinum(II) centers are held in position by intramolecular d(8)-d(8) Pt-Pt interaction. In its deprotonated "open" configuration, such Pt-Pt interaction is cleaved. To further understand the mechanism behind this hingelike motion, an analogous dinuclear cycloplatinated complex, {[Pt(L)](2)(mu-dchpm)}(2+) (Pt(2)dchpm) with bis(dicyclohexylphosphino)methane (dchpm) as the bridging ligand, was synthesized. From its protonation/deprotonation responses, it was revealed that aromatic pi-pi interactions between the phenyl moieties of the mu-dppm and the deprotonated pyrazolyl rings of L was essential to the reversible cleavage of the intramolecular Pt-Pt interaction in Pt(2)dppm. In the case of Pt(2)dchpm, spectroscopic and spectrofluorometric titrations as well as X-ray crystallography indicated that the distance between the two platinum(II) centers shrank upon deprotonation, thus causing a redshift in its room-temperature triplet metal-metal-to-ligand charge-transfer emission from 614 to 625 nm. Ab initio calculations revealed the presence of intramolecular hydrogen bonding between the deprotonated and negatively charged 1-pyrazolyl-N moiety and the methylene CH and phenyl C-H of the mu-dppm. The "open" configuration of the deprotonated Pt(2)dppm was estimated to be 19 kcal mol(-1) more stable than its alternative "closed" configuration. On the other hand, the open configuration of the deprotonated Pt(2)dchpm was 6 kcal mol(-1) less stable than its alternative closed configuration.
Modeling, Materials, and Metrics: The Three-m Approach to FCS Signature Solutions
2002-05-07
calculations. These multiple levels will be incorporated into the MuSES software. The four levels are described as follows: "* Radiosity - Deterministic...view-factor-based, all-diffuse solution. Very fast. Independent of user position. "* Directional Reflectivity - Radiosity with directional incident...target and environment facets (view factor with BRDF). Last ray cast bounce = radiosity solution. "* Multi-bounce path trace - Rays traced from observer
COMPLEX RUTHENIUM ACIDO-NITROS COMPOUNDS (in Russian)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zvyagintsev, O.E.; Starostin, S.M.
1961-06-01
The chemical nature of the water in the complex ruthenium acidonitroso compounds is studied by measuring certain acid properties, reactions, and behaviors of the compounds in aqueous solution. The dependence of molecular electrical conductivity on time and dilution, variations of specific electroconductivity, the optical density, and the light absorption of the compounds at 200 to 800 m mu wave range were investigated and the dissociation constants were calculated. (R.V.J.)
NASA Astrophysics Data System (ADS)
Angeli, C.; Cimiraglia, R.
2005-02-01
Starting from a CAS-SCF calculation a sequence of contracted functions can be generated by applying strings of spin-traced replacement operators to the CAS-SCF solution. The laborious task of producing the Hamiltonian matrix elements between such functions can be substantially reduced making use of a computer algebra system. An implementation employing the MuPAD system is presented and illustrated.
Forced Two-Phase Helium Cooling Scheme for the Mu2e Transport Solenoid
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tatkowski, G.; Cheban, S.; Dhanaraj, N.
2015-01-01
The Mu2e Transport Solenoid (TS) is an S-shaped magnet formed by two separate but similar magnets, TS-u and TS-d. Each magnet is quarter-toroid shaped with a centerline radius of approximately 3 m utilizing a helium cooling loop consisting of 25 to 27 horizontal-axis rings connected in series. This cooling loop configuration has been deemed adequate for cooling via forced single phase liquid helium; however it presents major challenges to forced two-phase flow such as “garden hose” pressure drop, concerns of flow separation from tube walls, difficulty of calculation, etc. Even with these disadvantages, forced two-phase flow has certain inherent advantagesmore » which make it a more attractive option than forced single phase flow. It is for this reason that the use of forced two-phase flow was studied for the TS magnets. This paper will describe the analysis using helium-specific pressure drop correlations, conservative engineering approach, helium properties calculated and updated at over fifty points, and how the results compared with those in literature. Based on the findings, the use of forced-two phase helium is determined to be feasible for steady-state cooling of the TS solenoids« less
Measurement of the muonic branching fractions of the narrow upsilon resonances.
Adams, G S; Chasse, M; Cravey, M; Cummings, J P; Danko, I; Napolitano, J; Cronin-Hennessy, D; Park, C S; Park, W; Thayer, J B; Thorndike, E H; Coan, T E; Gao, Y S; Liu, F; Stroynowski, R; Artuso, M; Boulahouache, C; Blusk, S; Butt, J; Dambasuren, E; Dorjkhaidav, O; Menaa, N; Mountain, R; Muramatsu, H; Nandakumar, R; Redjimi, R; Sia, R; Skwarnicki, T; Stone, S; Wang, J C; Zhang, K; Csorna, S E; Bonvicini, G; Cinabro, D; Dubrovin, M; Bornheim, A; Pappas, S P; Weinstein, A J; Briere, R A; Chen, G P; Ferguson, T; Tatishvili, G; Vogel, H; Watkins, M E; Adam, N E; Alexander, J P; Berkelman, K; Cassel, D G; Duboscq, J E; Ecklund, K M; Ehrlich, R; Fields, L; Galik, R S; Gibbons, L; Gittelman, B; Gray, R; Gray, S W; Hartill, D L; Heltsley, B K; Hertz, D; Hsu, L; Jones, C D; Kandaswamy, J; Kreinick, D L; Kuznetsov, V E; Mahlke-Krüger, H; Meyer, T O; Onyisi, P U E; Patterson, J R; Peterson, D; Pivarski, J; Riley, D; Rosner, J L; Ryd, A; Sadoff, A J; Schwarthoff, H; Shepherd, M R; Sun, W M; Thayer, J G; Urner, D; Wilksen, T; Weinberger, M; Athar, S B; Avery, P; Breva-Newell, L; Patel, R; Potlia, V; Stoeck, H; Yelton, J; Rubin, P; Cawlfield, C; Eisenstein, B I; Gollin, G D; Karliner, I; Kim, D; Lowrey, N; Naik, P; Sedlack, C; Selen, M; Thaler, J J; Williams, J; Wiss, J; Edwards, K W; Besson, D; Gao, K Y; Gong, D T; Kubota, Y; Lang, B W; Li, S Z; Poling, R; Scott, A W; Smith, A; Stepaniak, C J; Urheim, J; Metreveli, Z; Seth, K K; Tomaradze, A; Zweber, P; Ernst, J; Mahmood, A H; Arms, K; Gan, K K; Asner, D M; Dytman, S A; Mehrabyan, S; Mueller, J A; Savinov, V; Li, Z; Lopez, A; Mendez, H; Ramirez, J; Huang, G S; Miller, D H; Pavlunin, V; Sanghi, B; Shibata, E I; Shipsey, I P J
2005-01-14
The decay branching fractions of the three narrow Upsilon resonances to mu(+)mu(-) have been measured by analyzing about 4.3 fb(-1) e(+)e(-) data collected with the CLEO III detector. The branching fraction B(Upsilon(1S)-->mu(+)mu(-))=(2.49+/-0.02+/-0.07)% is consistent with the current world average, but B(Upsilon(2S)-->mu(+)mu(-))=(2.03+/-0.03+/-0.08)% and B(Upsilon(3S)-->mu(+)mu(-))=(2.39+/-0.07+/-0.10)% are significantly larger than prior results. These new muonic branching fractions imply a narrower total decay width for the Upsilon(2S) and Upsilon(3S) resonances and lower other branching fractions that rely on these decays in their determination.
MuSK induced experimental autoimmune myasthenia gravis does not require IgG1 antibody to MuSK.
Küçükerden, Melike; Huda, Ruksana; Tüzün, Erdem; Yılmaz, Abdullah; Skriapa, Lamprini; Trakas, Nikos; Strait, Richard T; Finkelman, Fred D; Kabadayı, Sevil; Zisimopoulou, Paraskevi; Tzartos, Socrates; Christadoss, Premkumar
2016-06-15
Sera of myasthenia gravis (MG) patients with muscle-specific receptor kinase-antibody (MuSK-Ab) predominantly display the non-complement fixing IgG4 isotype. Similarly, mouse IgG1, which is the analog of human IgG4, is the predominant isotype in mice with experimental autoimmune myasthenia gravis (EAMG) induced by MuSK immunization. The present study was performed to determine whether IgG1 anti-MuSK antibody is required for immunized mice to develop EAMG. Results demonstrated a significant correlation between clinical severity of EAMG and levels of MuSK-binding IgG1+, IgG2+ and IgG3+ peripheral blood B cells in MuSK-immunized wild-type (WT) mice. Moreover, MuSK-immunized IgG1 knockout (KO) and WT mice showed similar EAMG severity, serum MuSK-Ab levels, muscle acetylcholine receptor concentrations, neuromuscular junction immunoglobulin and complement deposit ratios. IgG1 and IgG3 were the predominant anti-MuSK isotypes in WT and IgG1 KO mice, respectively. These observations demonstrate that non-IgG1 isotypes can mediate MuSK-EAMG pathogenesis. Copyright © 2016 Elsevier B.V. All rights reserved.
Matsuo, Miki; Hishinuma, Tomomi; Katayama, Yuki; Cui, Longzhu; Kapi, Maria; Hiramatsu, Keiichi
2011-09-01
The clinical vancomycin-intermediate Staphylococcus aureus (VISA) strain Mu50 carries two mutations in the vraSR and graRS two-component regulatory systems (TCRSs), namely, vraS(I5N) and graR(N197S) (hereinafter designated graR). The clinical heterogeneously vancomycin-intermediate S. aureus (hVISA) strain Mu3 shares with Mu50 the mutation in vraS that encodes the VraS two-component histidine kinase. Previously, we showed that introduction of the plasmid pgraR, carrying the mutated two-component response regulator graR, converted the hVISA strain Mu3 into VISA (vancomycin MIC = 4 mg/liter). Subsequently, however, we found that the introduction of a single copy of graR into the Mu3 chromosome by a gene replacement method did not confer on Mu3 the VISA phenotype. The gene-replaced strain Mu3graR thus obtained remained hVISA (MIC ≤ 2 mg/liter), although a small increase in vancomycin MIC was observed compared to that of the parent strain Mu3. Reevaluation of the Mu3 and Mu50 genomes revealed the presence of another mutation responsible for the expression of the VISA phenotype in Mu50. Here, we demonstrate that in addition to the two regulator mutations, a third mutation found in the Mu50 rpoB gene, encoding the RNA polymerase β subunit, was required for Mu3 to achieve the level of vancomycin resistance of Mu50. The selection of strain Mu3graR with rifampin gave rise to rpoB mutants with various levels of increased vancomycin resistance. Furthermore, 3 (33%) of 10 independently isolated VISA strains established from the heterogeneous subpopulations of Mu3graR were found to possess rpoB mutations with or without an accompanying rifampin-resistance phenotype. The data indicate that a sizable proportion of the resistant hVISA cell subpopulations is composed of spontaneous rpoB mutants with various degrees of increased vancomycin resistance.
Weeks, Douglas L; Keeney, Benjamin J; Evans, Peggy C; Moore, Quincy D; Conrad, Douglas A
2015-01-01
The HITECH Act of 2009 enabled the Centers for Medicare & Medicaid Services (CMS) to provide financial incentives to health care providers who demonstrate "meaningful use" (MU) of their electronic health records (EHRs). Despite stakeholder involvement in the rule-making phase, formal input about the MU program from a cross section of providers has not been reported since incentive payments began. To examine the perspectives and experiences of a random sample of health care professionals eligible for financial incentives (eligible professionals or EPs) for demonstrating meaningful use of their EHRs. It was hypothesized that EPs actively participating in the MU program would generally view the purported benefits of MU more positively than EPs not yet participating in the incentive program. Survey data were collected by mail from a random sample of EPs in Washington State and Idaho. Two follow-up mailings were made to non-respondents. The sample included EPs who had registered for incentive payments or attested to MU (MU-Active) and EPs not yet participating in the incentive program (MU-Inactive). The survey assessed perceptions of general realities and influences of MU on health care; views on the influence of MU on clinics; and personal views about MU. EP opinions were assessed with close- and open-ended items. Close-ended responses indicated that MU-Active providers were generally more positive about the program than MU-Inactive providers. However, the majority of respondents in both groups felt that MU would not reduce care disparities or improve the accuracy of patient information. The additional workload on EPs and their staff was viewed as too great a burden on productivity relative to the level of reimbursement for achieving MU goals. The majority of open-ended responses in each group reinforced the general perception that the MU program diverted attention from treating patients by imposing greater reporting requirements. Survey results indicate the need by CMS to step up engagement with EPs in future planning for the MU program, while also providing support for achieving MU standards.
p110α of PI3K is necessary and sufficient for quiescence exit in adult muscle satellite cells.
Wang, Gang; Zhu, Han; Situ, Chenghao; Han, Lifang; Yu, Youqian; Cheung, Tom H; Liu, Kai; Wu, Zhenguo
2018-04-13
Adult mouse muscle satellite cells (MuSCs) are quiescent in uninjured muscles. Upon injury, MuSCs exit quiescence in vivo to become activated, re-enter the cell cycle to proliferate, and differentiate to repair the damaged muscles. It remains unclear which extrinsic cues and intrinsic signaling pathways regulate quiescence exit during MuSC activation. Here, we demonstrated that inducible MuSC-specific deletion of p110α , a catalytic subunit of phosphatidylinositol 3-kinase (PI3K), rendered MuSCs unable to exit quiescence, resulting in severely impaired MuSC proliferation and muscle regeneration. Genetic reactivation of mTORC1, or knockdown of FoxO s, in p110α -null MuSCs partially rescued the above defects, making them key effectors downstream of PI3K in regulating quiescence exit. c-Jun was found to be a key transcriptional target of the PI3K/mTORC1 signaling axis essential for MuSC quiescence exit. Moreover, induction of a constitutively active PI3K in quiescent MuSCs resulted in spontaneous MuSC activation in uninjured muscles and subsequent depletion of the MuSC pool. Thus, PI3K-p110α is both necessary and sufficient for MuSCs to exit quiescence in response to activating signals. © 2018 The Authors.
Aad, G.; Abbott, B.; Abdallah, J.; ...
2016-07-11
In this study, a new search signature for excited leptons is explored. Excited muons are sought in the channelmore » $${pp}\\to \\mu {\\mu }^{* }\\to \\mu \\mu \\ {\\rm{jet}}\\;{\\rm{jet}}$$, assuming both the production and decay occur via a contact interaction. The analysis is based on 20.3 fb –1 of pp collision data at a centre-of-mass energy of $$\\sqrt{s}\\;=\\;8\\;{\\rm{TeV}}$$ taken with the ATLAS detector at the large hadron collider. No evidence of excited muons is found, and limits are set at the 95% confidence level on the cross section times branching ratio as a function of the excited-muon mass $${m}_{{\\mu }^{* }}$$. For $${m}_{{\\mu }^{* }}$$ between 1.3 and 3.0 TeV, the upper limit on $$\\sigma B({\\mu }^{* }\\to \\mu q\\bar{q}$$) is between 0.6 and 1 fb. Limits on $$\\sigma B$$ are converted to lower bounds on the compositeness scale Λ. In the limiting case $${\\rm{\\Lambda }}={m}_{{\\mu }^{* }}$$, excited muons with a mass below 2.8 TeV are excluded. With the same model assumptions, these limits at larger $${\\mu }^{* }$$ masses improve upon previous limits from traditional searches based on the gauge-mediated decay $${\\mu }^{* }\\to \\mu \\gamma $$.« less
Searches for lepton number violation and resonances in K ± → πμμ decays
DOE Office of Scientific and Technical Information (OSTI.GOV)
Batley, J. R.; Kalmus, G.; Lazzeroni, C.
The NA48/2 experiment at CERN collected a large sample of charged kaon decays to final states with multiple charged particles in 2003more » $-$2004. A new upper limit on the rate of the lepton number violating decay $$K^{\\pm}\\to\\pi^{\\mp}\\mu^{\\pm}\\mu^{\\pm}$$ is reported: $$\\mathcal{B}(K^{\\pm}\\to\\pi^{\\mp}\\mu^{\\pm}\\mu^{\\pm})<8.6 \\times 10^{-11}$$ at 90% CL. Searches for two-body resonances $X$ in $$K^{\\pm}\\to\\pi\\mu\\mu$$ decays (such as heavy neutral leptons $$N_4$$ and inflatons $$\\chi$$) are also presented. Finally, in the absence of signals, upper limits are set on the products of branching fractions $$\\mathcal{B}(K^{\\pm}\\to\\mu^{\\pm}N_4)\\mathcal{B}(N_4\\to\\pi\\mu)$$ and $$\\mathcal{B}(K^{\\pm}\\to\\pi^{\\pm}X)\\mathcal{B}(X\\to\\mu^+\\mu^-)$$ for ranges of assumed resonance masses and lifetimes. The limits are in the $$(10^{-11},10^{-9})$$ range for resonance lifetimes below 100 ps.« less
Searches for lepton number violation and resonances in K ± → πμμ decays
Batley, J. R.; Kalmus, G.; Lazzeroni, C.; ...
2017-03-18
The NA48/2 experiment at CERN collected a large sample of charged kaon decays to final states with multiple charged particles in 2003more » $-$2004. A new upper limit on the rate of the lepton number violating decay $$K^{\\pm}\\to\\pi^{\\mp}\\mu^{\\pm}\\mu^{\\pm}$$ is reported: $$\\mathcal{B}(K^{\\pm}\\to\\pi^{\\mp}\\mu^{\\pm}\\mu^{\\pm})<8.6 \\times 10^{-11}$$ at 90% CL. Searches for two-body resonances $X$ in $$K^{\\pm}\\to\\pi\\mu\\mu$$ decays (such as heavy neutral leptons $$N_4$$ and inflatons $$\\chi$$) are also presented. Finally, in the absence of signals, upper limits are set on the products of branching fractions $$\\mathcal{B}(K^{\\pm}\\to\\mu^{\\pm}N_4)\\mathcal{B}(N_4\\to\\pi\\mu)$$ and $$\\mathcal{B}(K^{\\pm}\\to\\pi^{\\pm}X)\\mathcal{B}(X\\to\\mu^+\\mu^-)$$ for ranges of assumed resonance masses and lifetimes. The limits are in the $$(10^{-11},10^{-9})$$ range for resonance lifetimes below 100 ps.« less
Observation of the Z$$\\to\\psi\\ell^+\\ell^-$$ decay in pp collisions at $$\\sqrt{s}=$$ 13 TeV
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sirunyan, Albert M; et al.
This Letter presents the observation of the rare Z boson decay Zmore » $$\\to\\psi\\ell^+\\ell^-$$. Here, $$\\psi$$ represents contributions from direct J/$$\\psi$$ and J/$$\\psi$$$\\to$$ J$$\\psi X$$, $$\\ell^+\\ell^-$$ is a pair of electrons or muons, and the J/$$\\psi$$ meson is detected via its decay to $$\\mu^+\\mu^-$$. The sample of proton-proton collision data, collected by the CMS experiment at the LHC at a center-of-mass energy of 13 TeV, corresponds to an integrated luminosity of 35.9 fb$$^{-1}$$. The signal is observed with a significance in excess of 5 standard deviations. After subtraction of the $$\\psi$$(2S) $$\\to$$J/$$\\psi X$$ contribution, the ratio of the branching fraction of the exclusive decay Z$$\\to\\psi\\ell^+\\ell^-$$ to the decay Z$$\\to\\mu^+\\mu^-\\mu^+\\mu^-$$ within a fiducial phase space is measured to be $$\\mathcal{B}($$Z$$\\to\\psi\\ell^+\\ell^-) / \\mathcal{B}($$Z$$\\to\\mu^+\\mu^-\\mu^+\\mu^-) =$$ 0.67$$\\pm$$ 0.18 (stat) $$\\pm$$ 0.05 (syst).« less
NASA Astrophysics Data System (ADS)
Chakraborty, B.; Davies, C. T. H.; Detar, C.; El-Khadra, A. X.; Gámiz, E.; Gottlieb, Steven; Hatton, D.; Koponen, J.; Kronfeld, A. S.; Laiho, J.; Lepage, G. P.; Liu, Yuzhi; MacKenzie, P. B.; McNeile, C.; Neil, E. T.; Simone, J. N.; Sugar, R.; Toussaint, D.; van de Water, R. S.; Vaquero, A.; Fermilab Lattice, Hpqcd,; Milc Collaborations
2018-04-01
All lattice-QCD calculations of the hadronic-vacuum-polarization contribution to the muon's anomalous magnetic moment to date have been performed with degenerate up- and down-quark masses. Here we calculate directly the strong-isospin-breaking correction to aμHVP for the first time with physical values of mu and md and dynamical u , d , s , and c quarks, thereby removing this important source of systematic uncertainty. We obtain a relative shift to be applied to lattice-QCD results obtained with degenerate light-quark masses of δ aμHVP ,mu≠md=+1.5 (7 )% , in agreement with estimates from phenomenology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feldman, S.C.; Taranik, J.V.
1986-05-01
Selected areas were mapped at a scale of 1:6000 in the southern hot Creek Range (south-central Nevada), which is underlain by Paleozoic autochthonous limestone, shale, and sandstone, Paleozoic allochthonous chert and siltstone, and Tertiary rhyolitic to dactitic ash flow tuff. The mapping was compared with computer-processed Airborne Imaging Spectrometer (AIS) data and Landsat Thematic Mapper (TM) imagery. The AIS imagery of the Hot Creek Range was acquired in 1984 by a NASA C-130 aircraft; it has a spatial resolution of 12 m, and swath width of 380 m. The sensor was developed by the Jet Propulsion Laboratory and is themore » first in a series of NASA imaging spectrometers. The AIS collects 128 spectral bands, having a bandwidth of approximately 9 nm, in the short-wave infrared between 1.2 and 2.4 ..mu..m. This part of the spectrum contains important narrow spectral absorption features for the carbonate ion, hydroxyl ion, and water of hydration. Using computer-processed AIS imagery, therefore, the authors can separate calcite from dolomite, and kaolinite from illite and montmorillonite as well as differentiate geologic units containing these minerals. On the AIS imagery, the Upper Mississippian Tripon Pass Limestone shows a distinctive calcite absorption feature at 2.34 ..mu..m; this feature is not as pronounced in Cambrian and Ordovician limestones. The dolomitized Nevada Formation exhibits the dolomite absorption feature at 2.32 ..mu..m. Clay mineral absorption features near 2.2 ..mu..m can be distinguished in altered volcanics. Mineralogic identification was confirmed with field and laboratory spectroradiometer measurements, thin-section examination, and x-ray analysis. AIS results and field mapping were also compared to computer-processed Landsat TM imagery, the highest spectral and spatial resolution worldwide data set currently available.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ng, Y.C.; Akera, T.
1986-03-05
Characteristics of more than one class of ouabain receptors which appear to exist in ferret heart were examined. In isolated papillary muscle, 1 to 30 nM ouabain produced a positive inotropic effect in the presence of 5 ..mu..M propranolol and 2 ..mu..M phentolamine. Higher concentrations of ouabain (0.1 to 10 ..mu..M) produced an additional and prominent inotropic effect. In partially purified Na, K-ATPase, ouabain caused a monophasic inhibition; however, the concentration-inhibition curve spanned over 5 log units, indicating that ouabain is interacting with more than a single class of the enzyme. Scatchard analysis of specific /sup 3/H-ouabain binding revealed approximatelymore » equal abundance of high and low affinity binding sites. The K/sub D/ value for high affinity sites was approximately 20 nM whereas that for low affinity sites was about 45 times higher. When phosphoenzyme was formed in the presence of (..gamma..-/sup 32/P)-ATP, Mg/sup 2 +/ and Na/sup +/ and subjected to SDS gel electrophoresis, two distinct K/sup +/-sensitive bands with about 100,000 dalton molecular weight were detected. Molecular weight difference between these two bands was approximately 2500 dalton. Phosphorylation of either band was abolished by 1 ..mu..M ouabain suggesting that both bands may correspond to the high-affinity binding sites. These results indicate that high and low affinity ouabain binding sites exists in approximately equal abundance in the ferret heart, and that binding of ouabain to these sites cases Na,K-ATPase inhibition and the positive inotropic effect.« less
Inherited glutathione-S-transferase deficiency is a risk factor for pulmonary asbestosis.
Smith, C M; Kelsey, K T; Wiencke, J K; Leyden, K; Levin, S; Christiani, D C
1994-09-01
Pulmonary diseases attributable to asbestos exposure constitute a significant public health burden, yet few studies have investigated potential genetic determinants of susceptibility to asbestos-related diseases. The glutathione-S-transferases are a family of conjugating enzymes that both catalyze the detoxification of a variety of potentially cytotoxic electrophilic agents and act in the generation of sulfadipeptide leukotriene inflammatory mediators. The gene encoding glutathione-S-transferase class mu (GSTM-1) is polymorphic; approximately 50% of Caucasian individuals have a homozygous deletion of this gene and do not produce functional enzyme. Glutathione-S-transferase mu (GST-mu) deficiency has been previously reported to be associated with smoking-induced lung cancer. We conducted a cross-sectional study to examine the prevalence of the homozygous deletion for the GSTM-1 gene in members of the carpentry trade occupationally exposed to asbestos. Members of the United Brotherhood of Carpenters and Joiners of America attending their 1991 National Union conference were invited to participate. Each participant was offered a chest X-ray and was asked to complete a comprehensive questionnaire and have their blood drawn. All radiographs were assessed for the presence of pneumoconiosis in a blinded fashion by a National Institute for Occupational Safety and Health-certified International Labor Office "B" reader. Individual GSTM-1 status was determined using polymerase chain reaction methods. Six hundred fifty-eight workers were studied. Of these, 80 (12.2%) had X-ray abnormalities associated with asbestos exposure. Individuals genetically deficient in GST-mu were significantly more likely to have radiographic evidence of nonmalignant asbestos-related disease than those who were not deficient (chi 2 = 5.0; P < 0.03).(ABSTRACT TRUNCATED AT 250 WORDS)
DOE R&D Accomplishments Database
Feinberg, G.; Weinberg, S.
1961-02-01
A multiplicative selection rule for mu meson-electron transitions is proposed. A "muon parity" = -1 is considered for the muon and its neutrino, while the "muon parity" for all other particles is +1. The selection rule then states that (-1) exp(no. of initial (-1) parity particles) = (-1) exp(no. of final (-1) parity particles). Several reactions that are forbidden by an additive law but allowed by the multiplicative law are suggested; these reactions include mu{sup +} .> e{sup +} + nu{sub mu} + {ovr nu}{sub e}, e{sup -} + e{sup -} .> mu{sup -} + mu{sup -}, and muonium .> antimuonium (mu{sup +} + e{sup -} .> mu{sup -} + e{sup +}). An intermediate-boson hypothesis is suggested. (T.F.H.)
SPITZER MIPS 24 and 70 {mu}m IMAGING NEAR THE SOUTH ECLIPTIC POLE: MAPS AND SOURCE CATALOGS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scott, Kimberly S.; Stabenau, Hans F.; Devlin, Mark J.
2010-12-15
We have imaged an 11.5 deg{sup 2} region of sky toward the South Ecliptic Pole (R.A. =04{sup h}43{sup m}, decl. =-53{sup 0}40', J2000) at 24 and 70 {mu}m with MIPS, the Multiband Imaging Photometer for Spitzer. This region is coincident with a field mapped at longer wavelengths by AKARI and BLAST. We discuss our data reduction and source extraction procedures. The median 1{sigma} depths of the maps are 47 {mu}Jy beam{sup -1} at 24 {mu}m and 4.3 mJy beam{sup -1} at 70 {mu}m. At 24 {mu}m, we identify 93,098 point sources with signal-to-noise ratio (S/N) {>=}5 and an additional 63more » resolved galaxies; at 70 {mu}m we identify 891 point sources with S/N {>=}6. From simulations, we determine a false detection rate of 1.8% (1.1%) for the 24 {mu}m (70 {mu}m) catalog. The 24 and 70 {mu}m point-source catalogs are 80% complete at 230 {mu}Jy and 11 mJy, respectively. These mosaic images and source catalogs will be available to the public through the NASA/IPAC Infrared Science Archive.« less
Feral pig populations are structured at fine spatial scales in tropical Queensland, Australia.
Lopez, Jobina; Hurwood, David; Dryden, Bart; Fuller, Susan
2014-01-01
Feral pigs occur throughout tropical far north Queensland, Australia and are a significant threat to biodiversity and World Heritage values, agriculture and are a vector of infectious diseases. One of the constraints on long-lasting, local eradication of feral pigs is the process of reinvasion into recently controlled areas. This study examined the population genetic structure of feral pigs in far north Queensland to identify the extent of movement and the scale at which demographically independent management units exist. Genetic analysis of 328 feral pigs from the Innisfail to Tully region of tropical Queensland was undertaken. Seven microsatellite loci were screened and Bayesian clustering methods used to infer population clusters. Sequence variation at the mitochondrial DNA control region was examined to identify pig breed. Significant population structure was identified in the study area at a scale of 25 to 35 km, corresponding to three demographically independent management units (MUs). Distinct natural or anthropogenic barriers were not found, but environmental features such as topography and land use appear to influence patterns of gene flow. Despite the strong, overall pattern of structure, some feral pigs clearly exhibited ancestry from a MU outside of that from which they were sampled indicating isolated long distance dispersal or translocation events. Furthermore, our results suggest that gene flow is restricted among pigs of domestic Asian and European origin and non-random mating influences management unit boundaries. We conclude that the three MUs identified in this study should be considered as operational units for feral pig control in far north Queensland. Within a MU, coordinated and simultaneous control is required across farms, rainforest areas and National Park Estates to prevent recolonisation from adjacent localities.
Characterization of MUDENG, a novel anti-apoptotic protein
Choi, J-H; Lim, J-B; Wickramanayake, D D; Wagley, Y; Kim, J; Lee, H-C; Seo, H G; Kim, T-H; Oh, J-W
2016-01-01
MUDENG (Mu-2-related death-inducing gene, MuD) is revealed to be involved in cell death signaling. Astrocytes, the major glial cell type in the central nervous system, are a source of brain tumors. In this study, we examined MuD expression and function in human astroglioma cells. Stimulation of U251-MG cells with tumor necrosis factor-related apoptosis-inducing ligand (TRAIL) resulted in a 40% decrease in cell viability and a 33% decrease in MuD protein levels, although not in MuD mRNA levels. To study the functional relevance of MuD expression, stable transfectants expressing high levels of MuD were generated. Stimulation of these transfectants with TRAIL resulted in enhanced cell survival (77% for stable and 46% for control transfectants). Depletion of MuD led to a marked reduction upon TRAIL stimulation in cell viability (22% in MuD-depleted cells and 54% in control cells). In addition, we observed that MuD depletion increased the susceptibility of the cells to TRAIL by enhancing the cleavage of caspase-3/-9 and BH3-interacting domain death agonist (Bid). A unique 25-kDa fragment of B-cell lymphoma 2 (Bcl-2) lacking BH4 was observed 60–180 min post TRAIL treatment in MuD-depleted cells, suggesting that Bcl-2 is converted from its anti-apoptotic form to the truncated pro-apoptotic form. Importantly, the TRAIL-mediated decrease in cell viability in MuD-depleted cells was abrogated upon Bid depletion, indicating that the role of MuD in apoptotic signaling takes place at the Bid and Bcl-2 junction. MuD localizes predominantly in the endoplasmic reticulum and partly in the mitochondria and its amounts are reduced 6 h post TRAIL stimulation, presumably via caspase-3-mediated MuD cleavage. Collectively, these results suggest that MuD, a novel signaling protein, not only possesses an anti-apoptotic function but may also constitute an important target for the design of ideal candidates for combinatorial treatment strategies for glioma cells. PMID:27136675
Deduced Inference in the Analysis of Experimental Data
ERIC Educational Resources Information Center
Bird, Kevin D.
2011-01-01
Any set of confidence interval inferences on J - 1 linearly independent contrasts on J means, such as the two comparisons [mu][subscript 1] - [mu][subscript 2] and [mu][subscript 2] - [mu][subscript 3] on 3 means, provides a basis for the deduction of interval inferences on all other contrasts, such as the redundant comparison [mu][subscript 1] -…
NASA Astrophysics Data System (ADS)
Bradley, A. M.
2013-12-01
My poster will describe dc3dm, a free open source software (FOSS) package that efficiently forms and applies the linear operator relating slip and traction components on a nonuniformly discretized rectangular planar fault in a homogeneous elastic (HE) half space. This linear operator implements what is called the displacement discontinuity method (DDM). The key properties of dc3dm are: 1. The mesh can be nonuniform. 2. Work and memory scale roughly linearly in the number of elements (rather than quadratically). 3. The order of accuracy of my method on a nonuniform mesh is the same as that of the standard method on a uniform mesh. Property 2 is achieved using my FOSS package hmmvp [AGU 2012]. A nonuniform mesh (property 1) is natural for some problems. For example, in a rate-state friction simulation, nucleation length, and so required element size, scales reciprocally with effective normal stress. Property 3 assures that if a nonuniform mesh is more efficient than a uniform mesh (in the sense of accuracy per element) at one level of mesh refinement, it will remain so at all further mesh refinements. I use the routine DC3D of Y. Okada, which calculates the stress tensor at a receiver resulting from a rectangular uniform dislocation source in an HE half space. On a uniform mesh, straightforward application of this Green's function (GF) yields a DDM I refer to as DDMu. On a nonuniform mesh, this same procedure leads to artifacts that degrade the order of accuracy of the DDM. I have developed a method I call IGA that implements the DDM using this GF for a nonuniformly discretized mesh having certain properties. Importantly, IGA's order of accuracy on a nonuniform mesh is the same as DDMu's on a uniform one. Boundary conditions can be periodic in the surface-parallel direction (in both directions if the GF is for a whole space), velocity on any side, and free surface. The mesh must have the following main property: each uniquely sized element must tile each element larger than itself. A mesh generated by a family of quadtrees has this property. Using multiple quadtrees that collectively cover the domain enables the elements to have a small aspect ratio. Mathematically, IGA works as follows. Let Mn be the nonuniform mesh. Define Mu to be the uniform mesh that is composed of the smallest element in Mn. Every element e in Mu has associated subelements in Mn that tile e. First, a linear operator Inu mapping data on Mn to Mu implements smooth (C^1) interpolation; I use cubic (Clough-Tocher) interpolation over a triangulation induced by Mn. Second, a linear operator Gu implements DDMu on Mu. Third, a linear operator Aun maps data on Mu to Mn. These three linear operators implement exact IGA (EIGA): Gn = Aun Gu Inu. Computationally, there are several more details. EIGA has the undesirable property that calculating one entry of Gn for receiver ri requires calculating multiple entries of Gu, no matter how far away from ri the smallest element is. Approximate IGA (AIGA) solves this problem by restricting EIGA to a neighborhood around each receiver. Associated with each neighborhood is a minimum element size s^i that indexes a family of operators Gu^i. The order of accuracy of AIGA is the same as that of EIGA and DDMu if each neighborhood is kept constant in spatial extent as the mesh is refined.
Cadmium resistance in tobacco plants expressing the MuSI gene.
Kim, Young-Nam; Kim, Ji-Seoung; Seo, Sang-Gyu; Lee, Youngwoo; Baek, Seung-Woo; Kim, Il-Sup; Yoon, Ho-Sung; Kim, Kwon-Rae; Kim, Sun-Hyung; Kim, Kye-Hoon
2011-10-01
MuSI, a gene that corresponds to a domain that contains the rubber elongation factor (REF), is highly homologous to many stress-related proteins in plants. Since MuSI is up-regulated in the roots of plants treated with cadmium or copper, the involvement of MuSI in cadmium tolerance was investigated in this study. Escherichia coli cells overexpressing MuSI were more resistant to Cd than wild-type cells transfected with vector alone. MuSI transgenic plants were also more resistant to Cd. MuSI transgenic tobacco plants absorbed less Cd than wild-type plants. Cd translocation from roots to shoots was reduced in the transgenic plants, thereby avoiding Cd toxicity. The number of short trichomes in the leaves of wild-type tobacco plants was increased by Cd treatment, while this was unchanged in MuSI transgenic tobacco. These results suggest that MuSI transgenic tobacco plants have enhanced tolerance to Cd via reduced Cd uptake and/or increased Cd immobilization in the roots, resulting in less Cd translocation to the shoots.
Sarkar, Biprajit; Patra, Srikanta; Fiedler, Jan; Sunoj, Raghavan B; Janardanan, Deepa; Lahiri, Goutam Kumar; Kaim, Wolfgang
2008-03-19
Electron-rich Ru(acac)2 (acac- = 2,4-pentanedionato) binds to the pi electron-deficient bis-chelate ligands L, L = 2,2'-azobispyridine (abpy) or azobis(5-chloropyrimidine) (abcp), with considerable transfer of negative charge. The compounds studied, (abpy)Ru(acac)2 (1), meso-(mu-abpy)[Ru(acac)2]2 (2), rac-(mu-abpy)[Ru(acac)2]2 (3), and (mu-abcp)[Ru(acac)2]2 (4), were calculated by DFT to assess the degree of this metal-to-ligand electron shift. The calculated and experimental structures of 2 and 3 both yield about 1.35 A for the length of the central N-N bond which suggests a monoanion character of the bridging ligand. The NBO analysis confirms this interpretation, and TD-DFT calculations reproduce the observed intense long-wavelength absorptions. While mononuclear 1 is calculated with a lower net ruthenium-to-abpy charge shift as illustrated by the computed 1.30 A for d(N-N), compound 4 with the stronger pi accepting abcp bridge is calculated with a slightly lengthened N-N distance relative to that of 2. The formulation of the dinuclear systems with monoanionic bridging ligands implies an obviously valence-averaged Ru(III)Ru(II) mixed-valent state for the neutral molecules. Mixed valency in conjunction with an anion radical bridging ligand had been discussed before in the discussion of MLCT excited states of symmetrically dinuclear coordination compounds. Whereas 1 still exhibits a conventional electrochemical and spectroelectrochemical behavior with metal centered oxidation and two ligand-based one-electron reduction waves, the two one-electron oxidation and two one-electron reduction processes for each of the dinuclear compounds Ru2.5(L*-)Ru2.5 reveal more unusual features via EPR and UV-vis-NIR spectroelectrochemistry. In spite of intense near-infrared absorptions, the EPR results show that the first reduction leads to Ru(II)(L*-)Ru(II) species, with an increased metal contribution for system 4*-. The second reduction to Ru(II)(L2-)Ru(II) causes the disappearance of the NIR band. One-electron oxidation of the Ru2.5(L*-)Ru2.5 species produces a metal-centered spin for which the alternatives RuIII(L0)Ru(II) or Ru(III)(L*-)Ru(III) can be formulated. The absence of NIR bands as common for mixed-valent species with intervalence charge transfer (IVCT) absorption favors the second alternative. The second one-electron oxidation is likely to produce a dication with Ru(III)(L0)Ru(III) formulation. The usefulness and limitations of the increasingly popular structure/oxidation state correlations for complexes with noninnocent ligands is being discussed.
Shea, Christopher M; Reiter, Kristin L; Weaver, Mark A; McIntyre, Molly; Mose, Jason; Thornhill, Jonathan; Malone, Robb; Weiner, Bryan J
2014-12-14
Meaningful Use (MU) provides financial incentives for electronic health record (EHR) implementation. EHR implementation holds promise for improving healthcare delivery, but also requires substantial changes for providers and staff. Establishing readiness for these changes may be important for realizing potential EHR benefits. Our study assesses whether provider/staff perceptions about the appropriateness of MU and their departments' ability to support MU-related changes are associated with their reported readiness for MU-related changes. We surveyed providers and staff representing 47 ambulatory practices within an integrated delivery system. We assessed whether respondent's role and practice-setting type (primary versus specialty care) were associated with reported readiness for MU (i.e., willingness to change practice behavior and ability to document actions for MU) and hypothesized predictors of readiness (i.e., perceived appropriateness of MU and department support for MU). We then assessed associations between reported readiness and the hypothesized predictors of readiness. In total, 400 providers/staff responded (response rate approximately 25%). Individuals working in specialty settings were more likely to report that MU will divert attention from other patient-care priorities (12.6% vs. 4.4%, p = 0.019), as compared to those in primary-care settings. As compared to advanced-practice providers and nursing staff, physicians were less likely to have strong confidence in their department's ability to solve MU implementation problems (28.4% vs. 47.1% vs. 42.6%, p = 0.023) and to report strong willingness to change their work practices for MU (57.9% vs. 83.3% vs. 82.0%, p < 0.001). Finally, provider/staff perceptions about whether MU aligns with departmental goals (OR = 3.99, 95% confidence interval (CI) = 2.13 to 7.48); MU will divert attention from other patient-care priorities (OR = 2.26, 95% CI = 1.26 to 4.06); their department will support MU-related change efforts (OR = 3.99, 95% CI = 2.13 to 7.48); and their department will be able to solve MU implementation problems (OR = 2.26, 95% CI = 1.26 to 4.06) were associated with their willingness to change practice behavior for MU. Organizational leaders should gauge provider/staff perceptions about appropriateness and management support of MU-related change, as these perceptions might be related to subsequent implementation.
The Neuroanatomy of Sexual Dimorphism in Opioid Analgesia
2014-04-13
2012 for review). Studies utilizing orofacial , somatosensory or visceral pain assays typically report that morphine produces a significantly greater...Review The neuroanatomy of sexual dimorphism in opioid analgesia Dayna R. Loyd a, Anne Z. Murphy b,⁎ a Pain Management Research Area, United States...online 13 April 2014 Keywords: Pain Periaqueductal gray Morphine Mu opioid receptor The influence of sex has been neglected in clinical studies on pain
A telemedicine support for diabetes management: the T-IDDM project.
Bellazzi, R; Larizza, C; Montani, S; Riva, A; Stefanelli, M; d'Annunzio, G; Lorini, R; Gomez, E J; Hernando, E; Brugues, E; Cermeno, J; Corcoy, R; de Leiva, A; Cobelli, C; Nucci, G; Del Prato, S; Maran, A; Kilkki, E; Tuominen, J
2002-08-01
In the context of the EU funded Telematic Management of Insulin-Dependent Diabetes Mellitus (T-IDDM) project, we have designed, developed and evaluated a telemedicine system for insulin dependent diabetic patients management. The system relies on the integration of two modules, a Patient Unit (PU) and a Medical Unit (MU), able to communicate over the Internet and the Public Switched Telephone Network. Using the PU, patients are allowed to automatically download their monitoring data from the blood glucose monitoring device, and to send them to the hospital data-base; moreover, they are supported in their every day self monitoring activity. The MU provides physicians with a set of tools for data visualization, data analysis and decision support, and allows them to send messages and/or therapeutic advice to the patients. The T-IDDM service has been evaluated through the application of a formal methodology, and has been used by European patients and physicians for about 18 months. The results obtained during the project demonstration, even if obtained on a pilot study of 12 subjects, show the feasibility of the T-IDDM telemedicine service, and seem to substantiate the hypothesis that the use of the system could present an advantage in the management of insulin dependent diabetic patients, by improving communications and, potentially, clinical outcomes.
Toward tsunami early warning system in Indonesia by using rapid rupture durations estimation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Madlazim
2012-06-20
Indonesia has Indonesian Tsunami Early Warning System (Ina-TEWS) since 2008. The Ina-TEWS has used automatic processing on hypocenter; Mwp, Mw (mB) and Mj. If earthquake occurred in Ocean, depth < 70 km and magnitude > 7, then Ina-TEWS announce early warning that the earthquake can generate tsunami. However, the announcement of the Ina-TEWS is still not accuracy. Purposes of this research are to estimate earthquake rupture duration of large Indonesia earthquakes that occurred in Indian Ocean, Java, Timor sea, Banda sea, Arafura sea and Pasific ocean. We analyzed at least 330 vertical seismogram recorded by IRIS-DMC network using a directmore » procedure for rapid assessment of earthquake tsunami potential using simple measures on P-wave vertical seismograms on the velocity records, and the likelihood that the high-frequency, apparent rupture duration, T{sub dur}. T{sub dur} can be related to the critical parameters rupture length (L), depth (z), and shear modulus ({mu}) while T{sub dur} may be related to wide (W), slip (D), z or {mu}. Our analysis shows that the rupture duration has a stronger influence to generate tsunami than Mw and depth. The rupture duration gives more information on tsunami impact, Mo/{mu}, depth and size than Mw and other currently used discriminants. We show more information which known from the rupture durations. The longer rupture duration, the shallower source of the earthquake. For rupture duration greater than 50 s, the depth less than 50 km, Mw greater than 7, the longer rupture length, because T{sub dur} is proportional L and greater Mo/{mu}. Because Mo/{mu} is proportional L. So, with rupture duration information can be known information of the four parameters. We also suggest that tsunami potential is not directly related to the faulting type of source and for events that have rupture duration greater than 50 s, the earthquakes generated tsunami. With available real-time seismogram data, rapid calculation, rupture duration discriminant can be completed within 4-5 min after an earthquake occurs and thus can aid in effective, accuracy and reliable tsunami early warning for Indonesia region.« less
Evidence for the decay sigma+ --> pmu+ mu-.
Park, H K; Burnstein, R A; Chakravorty, A; Chen, Y C; Choong, W S; Clark, K; Dukes, E C; Durandet, C; Felix, J; Fu, Y; Gidal, G; Gustafson, H R; Holmstrom, T; Huang, M; James, C; Jenkins, C M; Jones, T; Kaplan, D M; Lederman, L M; Leros, N; Longo, M J; Lopez, F; Lu, L C; Luebke, W; Luk, K B; Nelson, K S; Perroud, J-P; Rajaram, D; Rubin, H A; Volk, J; White, C G; White, S L; Zyla, P
2005-01-21
We report the first evidence for the decay Sigma(+)-->pmu(+)mu(-) from data taken by the HyperCP (E871) experiment at Fermilab. Based on three observed events, the branching ratio is B(Sigma(+)-->pmu(+)mu(-))=[8.6(+6.6)(-5.4)(stat)+/-5.5(syst)]x10(-8). The narrow range of dimuon masses may indicate that the decay proceeds via a neutral intermediate state, Sigma(+)-->pP(0),P0-->mu(+)mu(-) with a P0 mass of 214.3+/-0.5 MeV/c(2) and branching ratio B(Sigma(+)-->pP(0),P0-->mu(+)mu(-))=[3.1(+2.4)(-1.9)(stat)+/-1.5(syst)]x10(-8).
Gafchromic EBT-XD film: Dosimetry characterization in high-dose, volumetric-modulated arc therapy.
Miura, Hideharu; Ozawa, Shuichi; Hosono, Fumika; Sumida, Naoki; Okazue, Toshiya; Yamada, Kiyoshi; Nagata, Yasushi
2016-11-08
Radiochromic films are important tools for assessing complex dose distributions. Gafchromic EBT-XD films have been designed for optimal performance in the 40-4,000 cGy dose range. We investigated the dosimetric characteristics of these films, including their dose-response, postexposure density growth, and dependence on scanner orientation, beam energy, and dose rate with applications to high-dose volumetric-modulated arc therapy (VMAT) verification. A 10 MV beam from a TrueBeam STx linear accelerator was used to irradiate the films with doses in the 0-4,000 cGy range. Postexposure coloration was analyzed at postirradiation times ranging from several minutes to 48 h. The films were also irradiated with 6 MV (dose rate (DR): 600 MU/min), 6 MV flattening filter-free (FFF) (DR: 1,400 MU/ min), and 10 MV FFF (DR: 2,400 MU/min) beams to determine the energy and dose-rate dependence. For clinical examinations, we compared the dose distribu-tion measured with EBT-XD films and calculated by the planning system for four VMAT cases. The red channel of the EBT-XD film exhibited a wider dynamic range than the green and blue channels. Scanner orientation yielded a variation of ~ 3% in the net optical density (OD). The difference between the film front and back scan orientations was negligible, with variation of ~ 1.3% in the net OD. The net OD increased sharply within the first 6 hrs after irradiation and gradually afterwards. No significant difference was observed for the beam energy and dose rate, with a variation of ~ 1.5% in the net OD. The gamma passing rates (at 3%, 3 mm) between the film- measured and treatment planning system (TPS)-calculated dose distributions under a high dose VMAT plan in the absolute dose mode were more than 98.9%. © 2016 The Authors.
Gafchromic EBT‐XD film: Dosimetry characterization in high‐dose, volumetric‐modulated arc therapy
Ozawa, Shuichi; Hosono, Fumika; Sumida, Naoki; Okazue, Toshiya; Yamada, Kiyoshi; Nagata, Yasushi
2016-01-01
Radiochromic films are important tools for assessing complex dose distributions. Gafchromic EBT‐XD films have been designed for optimal performance in the 40–4,000 cGy dose range. We investigated the dosimetric characteristics of these films, including their dose‐response, postexposure density growth, and dependence on scanner orientation, beam energy, and dose rate with applications to high‐dose volumetric‐modulated arc therapy (VMAT) verification. A 10 MV beam from a TrueBeam STx linear accelerator was used to irradiate the films with doses in the 0–4,000 cGy range. Postexposure coloration was analyzed at postirradiation times ranging from several minutes to 48 h. The films were also irradiated with 6 MV (dose rate (DR): 600 MU/min), 6 MV flattening filter‐free (FFF) (DR: 1,400 MU/ min), and 10 MV FFF (DR: 2,400 MU/min) beams to determine the energy and dose‐rate dependence. For clinical examinations, we compared the dose distribution measured with EBT‐XD films and calculated by the planning system for four VMAT cases. The red channel of the EBT‐XD film exhibited a wider dynamic range than the green and blue channels. Scanner orientation yielded a variation of ∼3% in the net optical density (OD). The difference between the film front and back scan orientations was negligible, with variation of ∼1.3% in the net OD. The net OD increased sharply within the first 6 hrs after irradiation and gradually afterwards. No significant difference was observed for the beam energy and dose rate, with a variation of ∼1.5% in the net OD. The gamma passing rates (at 3%, 3 mm) between the film‐ measured and treatment planning system (TPS)‐calculated dose distributions under a high dose VMAT plan in the absolute dose mode were more than 98.9%. PACS number(s): 87.56 Fc PMID:27929504
Lp-estimates on diffusion processes
NASA Astrophysics Data System (ADS)
Yan, Litan; Zhu, Bei
2005-03-01
Let be a diffusion process on given by where B=(Bt)t[greater-or-equal, slanted]0 is a standard Brownian motion starting at zero and [mu],[sigma] are two continuous functions on , and [sigma](x)>0 if x[not equal to]0. For a nonnegative continuous function [phi] we define the functional by , t[greater-or-equal, slanted]0. Then under suitable conditions we establish the relationship between Lp-norm of sup0[less-than-or-equals, slant]t[less-than-or-equals, slant][tau]Xt and Lp-norm of J[tau] for all stopping times [tau]. In particular, for a Bessel process Z of dimension [delta]>0 starting at zero, we show that the inequalities hold for all 0
0, where Cp and cp are some positive constants depending only on p, and H[mu],h[mu] are the inverses of x|->(e2[mu]x-2[mu]x-1)/2[mu]2 and x|->(e-2[mu]x+2[mu]x-1)/2[mu]2 on (0,[infinity]), respectively.
Chirping for efficiency enhancement of the free-electron laser
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moore, G.T.; Goldstein, J.C.
1988-01-01
One-dimensional numerical studies have been made of free-electron laser oscillators in which the incident electron energy varies (chirps) as a function of time over each micropulse. Optical radiation resonant with such micropulses is chirped in frequency. Highest calculated efficiency (up to 8.1% for wavelengths near 10 ..mu..m) has been obtained in cases where the optical pulse at saturation is short compared to the slippage. 8 refs., 7 figs., 1 tab.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schiller, A; Voinov, A; Algin, E
Two-step-cascade spectra in {sup 172}Yb have been measured after thermal neutron capture. they are compared to calculations based on experimental values of the level density and radiative strength function (RSF) obtained from the {sup 173}Yb(3{sup 3}He,{alpha}{gamma}){sup 172}Yb reaction. The multipolarity of a 6.5(15) {mu}{sub N}{sup 2} resonance at E{sub {gamma}} = 3.3(1) MeV in the RSF is determined to be M1 by this comparison.
Cadet, Patrick; Mantione, Kirk J; Stefano, George B
2003-05-15
Studies from our laboratory have revealed a novel mu opiate receptor, mu 3, which is expressed in both vascular tissues and leukocytes. The mu 3 receptor is selective for opiate alkaloids and is insensitive to opioid peptides. We now identify the mu 3 receptor at the molecular level using a 441-bp conserved region of the mu 1 receptor. Sequence analysis of the isolated cDNA suggests that it is a novel, alternatively spliced variant of the mu opiate receptor gene. To determine whether protein expressed from this cDNA exhibits the biochemical characteristics expected of the mu 3 receptor, the cDNA clone was expressed in a heterologous system. At the functional level, COS-1 cells transfected with the mu 3 receptor cDNA exhibited dose-dependent release of NO following treatment with morphine, but not opioid peptides (i.e., Met-enkephalin). Naloxone was able to block the effect of morphine on COS-1 transfected cells. Nontransfected COS-1 cells did not produce NO in the presence of morphine or the opioid peptides at similar concentrations. Receptor binding analysis with [(3)H]dihydromorphine further supports the opiate alkaloid selectivity and opioid peptide insensitivity of this receptor. These data suggest that this new mu opiate receptor cDNA encodes the mu 3 opiate receptor, since it exhibits biochemical characteristics known to be unique to this receptor (opiate alkaloid selective and opioid peptide insensitive). Furthermore, using Northern blot, RT-PCR, and sequence analysis, we have demonstrated the expression of this new mu variant in human vascular tissue, mononuclear cells, polymorphonuclear cells, and human neuroblastoma cells.
Iron abundance in the moon from magnetometer measurements
NASA Technical Reports Server (NTRS)
Parkin, C. W.; Dyal, P.; Daily, W. D.
1973-01-01
Apollo 12 and 15 lunar surface magnetometer data with simultaneous lunar orbiting Explorer 35 data are used to plot hysteresis curves for the whole moon. From these curves a whole-moon permeability mu = 1.029 + 0.024 or - 0.019 is calculated. This result implies that the moon is not composed entirely of paramagnetic material, but that ferromagnetic material such as free iron exists in sufficient amounts to dominate the bulk lunar susceptibility. From the magnetic data the ferromagnetic free iron abundance is calculated. Then for assumed compositional models of the moon the additional paramagnetic iron is determined, yielding total lunar iron content. The calculated abundances are as follows: ferromagnetic free iron = 5 + or - 4 wt. percent, and total iron in the moon = 9 + or - 4 wt. percent.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li Xinhua; Zhang Da; Liu, Bob
2012-07-15
Purpose: To provide transmission data for broad 25-39 kVp (kilovolt peak) W/Rh and 25-49 kVp W/Al (target/filter, W-tungsten, Rh-rhodium, and Al-aluminum) x-ray beams through common shielding materials, such as lead, concrete, gypsum wallboard, wood, steel, and plate glass. Methods: The unfiltered W-target x-ray spectra measured on a Selenia Dimensions system (Hologic Inc., Bedford, MA) set at 20-49 kVp were, respectively, filtered using 50-{mu}m Rh and 700-{mu}m Al, and were subsequently used for Monte Carlo calculations. The transmission of broad x-ray beams through shielding materials was simulated using Geant4 low energy electromagnetic physics package with photon- and electron-processes above 250 eV,more » including photoelectric effect, Compton scattering, and Rayleigh scattering. The calculated transmission data were fitted using Archer equation with a robust fitting algorithm. Results: The transmission of broad x-ray beams through the above-mentioned shielding materials was calculated down to about 10{sup -5} for 25-39 kVp W/Rh and 25-49 kVp W/Al. The fitted results of {alpha}, {beta}, and {gamma} in Archer equation were provided. The {alpha} values of kVp Greater-Than-Or-Slanted-Equal-To 40 were approximately consistent with those of NCRP Report No. 147. Conclusions: These data provide inputs for the shielding designs of x-ray imaging facilities with W-anode x-ray beams, such as from Selenia Dimensions.« less
Spin relaxation in geometrically frustrated pyrochlores
NASA Astrophysics Data System (ADS)
Dunsiger, Sarah Ruth
This thesis describes muSR experiments which focus on systems where the magnetic ions occupy the vertices of edge or corner sharing triangular units, in particular the pyrochlores A2B2O7. The scientific interest in pyrochlores is based on the fact that they display novel magnetic behaviour at low temperatures due to geometrical frustration. The ground state of these systems is sensitively dependent on such factors as the range of the spin-spin interactions, disorder, anisotropy, thermal and quantum fluctuations. For example, Y2Mo2O7 shows many features reminiscent of a conventional spin glass, even though this material has nominally zero chemical disorder. It is found that the muon spin polarisation obeys a time-field scaling relation which indicates that the spin-spin autocorrelation function has a power law form in time, in stark contrast with the exponential form often assumed for conventional magnets above their transition temperature. Gd2Ti2O7 shows long range order, but only at a temperature much lower than its Curie-Weiss temperature, a signature of a frustrated system. In the paramagnetic regime, it is well described by an isotropic Heisenberg Hamiltonian with nearest neighbour couplings in the presence of a Zeeman interaction, from which the spin-spin autocorrelation function may be calculated as a power series in time. The muon spin relaxation rate decreases with magnetic field as the Zeeman energy becomes comparable with the exchange coupling between Gd spins. Thus, an independent measure of the exchange coupling or equivalently the Gd spin fluctuation rate is extracted. By contrast, Tb2Ti2O7 has been identified as a type of cooperative paramagnet. Short range correlations develop below 50 K. However, there is no long range ordering down to very low temperatures (0.075 K). The Tb3+ ion is subject to strong crystal electric field effects: point charge calculations indicate that this system is Ising like at low temperatures. Thus this system may be analogous to water ice, a system theoretically predicted to have finite entropy at zero temperature. It is possible to qualitatively explain the unusual changes in T1-1 as a function of applied magnetic field which are also observed using muSR.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aranda, J. I.; Tututi, E. S.; Ramirez-Zavaleta, F.
The size of the branching ratios for the {tau}{yields}{mu}{gamma} and {tau}{yields}{mu}{gamma}{gamma} decays induced by a lepton flavor violating Higgs interaction H{tau}{mu} is studied in the framework of effective field theories. The best constraint on the H{tau}{mu} vertex, derived from the know measurement on the muon anomalous magnetic moment, is used to impose the upper bounds Br({tau}{yields}{mu}{gamma})<7.5x10{sup -10} and Br({tau}{yields}{mu}{gamma}{gamma})<2.3x10{sup -12}, which are more stringent than current experimental limits on this class of transitions.
Intermetallic communication in titanium(IV) ferrocenyldiketonates.
Dulatas, Lea T; Brown, Seth N; Ojomo, Edema; Noll, Bruce C; Cavo, Matthew J; Holt, Paul B; Wopperer, Matthew M
2009-11-16
A tetradentate bis(ferrocenyldiketonate) ligand, Fc(2)BobH(2), is prepared via Claisen condensation of acetylferrocene and 2,2'-biphenyldiacetyl chloride, and is metalated with titanium(IV) isopropoxide to give (Fc(2)Bob)Ti(O(i)Pr)(2) in good yield. The isopropoxide groups are replaced with di(4-nitrophenyl)phosphate groups on treatment with the corresponding acid, and with chlorides on treatment with trimethylsilyl chloride. Metathesis with catechol leads to the bis(o-hydroxyphenoxide) complex rather than the chelating catecholate complex. Hydrolysis selectively gives the mu-oxo trimer (Delta,Delta,Delta)/(Lambda,Lambda,Lambda)-{(Fc(2)Bob)Ti(mu-O)}(3). The solid-state structures of the mu-oxo trimer and the bis(o-hydroxyphenoxide) complex show that the ferrocene substituents are oriented proximal to the biphenyl backbone rather than pointed out toward the exogenous groups. The complexes show dramatic changes in color depending on the bound anions, ranging from the red isopropoxide (lambda(max) = 489 nm) to the green bis(di(4-nitrophenyl)phosphate) (lambda(max) = 653 nm). The oxidation potentials of the ferrocenes show modest shifts based on the titanium environment, but the redox potentials of the two ferrocenes are never separated by more than 60 mV. These results and those of density-functional theory (DFT) calculations indicate that the titanium interacts principally with the lowest unoccupied molecular orbital (LUMO) of the ferrocenyldiketonate and very little with its highest occupied molecular orbital (HOMO).
Laser beam-profile impression and target thickness impact on laser-accelerated protons
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schollmeier, M.; Harres, K.; Nuernberg, F.
Experimental results on the influence of the laser focal spot shape onto the beam profile of laser-accelerated protons from gold foils are reported. The targets' microgrooved rear side, together with a stack of radiochromic films, allowed us to deduce the energy-dependent proton source-shape and size, respectively. The experiments show, that shape and size of the proton source depend only weakly on target thickness as well as shape of the laser focus, although they strongly influence the proton's intensity distribution. It was shown that the laser creates an electron beam that closely follows the laser beam topology, which is maintained duringmore » the propagation through the target. Protons are then accelerated from the rear side with an electron created electric field of a similar shape. Simulations with the Sheath-Accelerated Beam Ray-tracing for IoN Analysis code SABRINA, which calculates the proton distribution in the detector for a given laser-beam profile, show that the electron distribution during the transport through a thick target (50 {mu}m Au) is only modified due to multiple small angle scattering. Thin targets (10 {mu}m) show large source sizes of over 100 {mu}m diameter for 5 MeV protons, which cannot be explained by multiple scattering only and are most likely the result of refluxing electrons.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rasmussen,P.; Beauchemin, S.; Nugent, M.
2008-01-01
This study examines factors affecting oral bioaccessibility of metals in household dust, in particular metal speciation, organic carbon content, and particle size, with the goal of addressing risk assessment information requirements. Investigation of copper (Cu) and zinc (Zn) speciation in two size fractions of dust (< 36 {mu} m and 80-150 {mu} m) using synchrotron X-ray absorption spectroscopy (XAS) indicates that the two metals are bound to different components of the dust: Cu is predominately associated with the organic phase of the dust, while Zn is predominately associated with the mineral fraction. Total and bioaccessible Cu, nickel (Ni), and Znmore » were determined (on dry weight basis) in the < 150 {mu} m size fraction of a set of archived indoor dust samples (n = 63) and corresponding garden soil samples (n = 66) from the City of Ottawa, Canada. The median bioaccessible Cu content is 66 {mu} g g-1 in dust compared to 5 {mu} g g-1 in soil; the median bioaccessible Ni content is 16 {mu} g g-1 in dust compared to 2 {mu} g g-1 in soil; and the median bioaccessible Zn content is 410 {mu} g g-1 in dust compared to 18 {mu} g g-1 in soil. For the same data set, the median total Cu content is 152 {mu} g g-1 in dust compared to 17 {mu} g g-1 in soil; the median total Ni content is 41 {mu} g g-1 in dust compared to 13 {mu} g g-1 in soil; and the median total Zn content is 626 {mu} g g-1 in dust compared to 84 {mu} g g-1 in soil. Organic carbon is elevated in indoor dust (median 28%) compared to soil (median 5%), and is a key factor controlling metal partitioning and therefore bioaccessibility. The results show that house dust and soil have distinct geochemical signatures and should not be treated as identical media in exposure and risk assessments. Separate measurements of the indoor and outdoor environment are essential to improve the accuracy of residential risk assessments.« less
Zhang, Chunmei; Liu, Ruiting; Zhang, Jie; Chen, Zhenxia; Zhou, Xigeng
2006-07-24
The reactivity of [Cp(2)Ln(mu-OH)(THF)]2 (Ln = Y (1), Er (2), Yb (3)) toward PhEtCCO, PhNCO, Cp3Ln, [Cp2Ln(mu-CH3)]2, and the LiCl adduct of Cp2Ln(n)Bu(THF)x was examined. In all cases, OH-centered reactivity is observed: complexes 1-3 react with PhEtCCO to form the O-H addition products [Cp2Ln(mu-eta1:eta2-O2CCHEtPh)]2 (Ln = Yb (5), Er (6), Y (7), respectively, for 1-3), whereas treatment of 1 with PhNCO affords the addition/CpH-elimination/rearrangement product [{Cp2Y(THF)}2(mu-eta2:eta2-O2CNPh)] (8), which contains an unusual PhNCO(2) dianionic ligand. Analogous compound [Cp2Ln(THF)]2(mu-eta2:eta2-O2CNPh) (Ln = Yb (9), Er (10)) and 8 can be obtained in a higher yield by treatment of [Cp2Ln(mu-OH)(THF)]2 with PhNCO followed by reaction with the corresponding Cp3Ln. However, attempts to prepare the corresponding heterobimetallic complex by reacting stoichiometric amounts of [Cp2Y(mu-OH)(THF)]2 with PhNCO followed by treating it with Cp3Yb are unsuccessful. Instead, only rearrangement products 8 and 9 are obtained. Furthermore, the reaction of 3 with [Cp2Yb(mu-CH3)]2 or Cp3Yb forms oxo-bridged compound [Cp2Yb(THF)]2(mu-O) (11), whereas the reaction of [Cp2ErCl]2 with Li(n)Bu followed by treatment with 2 affords unexpected mu-oxo lanthanocene cluster (Cp2Er)3(mu-OH)(mu3-O)(mu-Cl)Li(THF)4 (12). In contrast to 1 and 2, 3 shows a strong tendency to undergo the intermolecular elimination of CpH at room temperature, giving trinuclear species [Cp2Yb(mu-OH)]2[CpYb(THF)](mu3-O) (4). The single-crystal X-ray diffraction structures of 1, 2, and 4-12 are described. All the results offer an interesting contrast to transition- and main-metal hydroxide complexes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, W.-L.; Chen, B.-W.; Tan, H.-Q.
2010-02-15
Employing the ionothermal synthesis approach, three new transition-metal-containing polyoxotungstate hybrids: [Dmim]{sub 2}Na{sub 3}[SiW{sub 11}O{sub 39}Fe(H{sub 2}O)].H{sub 2}O (Dmim=1,3-Dimethylimidazole) (1), [Emim]{sub 9}Na{sub 8}[(SiW{sub 9}O{sub 34}){sub 3}{l_brace}Fe{sub 3}(mu{sub 2}-OH){sub 2}(mu{sub 3}-O){r_brace}{sub 3}(WO{sub 4})].0.5H{sub 2}O (Emim=1-Ethyl-3-meth-ylimidazole) (2) and [Dmim]2[HMim]Na{sub 6}[(AsW{sub 9}O{sub 33}){sub 2}{l_brace}Mn{sup III}(H{sub 2}O){r_brace}{sub 3}].3H{sub 2}O (Dmim=1,3-Dimethylimidazole; Mim=1-Methylimidazole) (3) have been synthesized in 1-ethyl-3-methyl imidazolium bromide ([Emim]Br) ionic liquids (ILs). Compound 1 possesses a 3-D open framework constructed from the mono-iron{sup III}-substituted alpha-Keggin-type anion and the organic cations [Dmim]+ through the hydrogen bond interactions. Compound 2 contains a [{l_brace}Fe{sup III}{sub 3}(mu{sub 2}-OH){sub 2}(mu{sub 3}-O){r_brace}{sub 3}(mu{sub 4}-WO{sub 4})] cluster surrounded by three [SiW{submore » 9}O{sub 34}]{sup 10-} ligands, eight sodium cations and nine dissociative [Emim]{sup +} cations around the polyoxoanion. The polyoxoanion of 3 consists of a high-valent trinuclear-manganese (III)-substituted sandwiching polyoxoanion based on the [alpha-AsW{sub 9}O{sub 33}]{sup 9-} units. All the compounds are characterized by elemental analyses, IR, UV-vis spectra, TG-DTA and XRD analyses. The XPS and EPR spectra of Mn{sup III} in 3 were studied. The photocatalytic and electrocatalytic properties, as well as the stabilities of 1-3 were also investigated. - Graphical abstract: Three new transition-metal-containing polyoxotungstate hybrids were synthesized successfully under the ionothermal condition, which proves that the ionothermal synthesis is a suitable synthetic method for different kinds of polyoxometalates.« less
Chen, Huixiao; Winey, Brian A; Daartz, Juliane; Oh, Kevin S; Shin, John H; Gierga, David P
2015-01-01
To evaluate plan quality and delivery efficiency gains of volumetric modulated arc therapy (VMAT) versus a multicriteria optimization-based intensity modulated radiation therapy (MCO-IMRT) for stereotactic radiosurgery of spinal metastases. MCO-IMRT plans (RayStation V2.5; RaySearch Laboratories, Stockholm, Sweden) of 10 spinal radiosurgery cases using 7-9 beams were developed for clinical delivery, and patients were replanned using VMAT with partial arcs. The prescribed dose was 18 Gy, and target coverage was maximized such that the maximum dose to the planning organ-at-risk volume (PRV) of the spinal cord was 10 or 12 Gy. Dose-volume histogram (DVH) constraints from the clinically acceptable MCO-IMRT plans were utilized for VMAT optimization. Plan quality and delivery efficiency with and without collimator rotation for MCO-IMRT and VMAT were compared and analyzed based upon DVH, planning target volume coverage, homogeneity index, conformity number, cord PRV sparing, total monitor units (MU), and delivery time. The VMAT plans were capable of matching most DVH constraints from the MCO-IMRT plans. The ranges of MU were 4808-7193 for MCO-IMRT without collimator rotation, 3509-5907 for MCO-IMRT with collimator rotation, 4444-7309 for VMAT without collimator rotation, and 3277-5643 for VMAT with collimator of 90 degrees. The MU for the VMAT plans were similar to their corresponding MCO-IMRT plans, depending upon the complexity of the target and PRV geometries, but had a larger range. The delivery times of the MCO-IMRT and VMAT plans, both with collimator rotation, were 18.3 ± 2.5 minutes and 14.2 ± 2.0 minutes, respectively (P < .05). The MCO-IMRT and VMAT can create clinically acceptable plans for spinal radiosurgery. The MU for MCO-IMRT and VMAT can be reduced significantly by utilizing a collimator rotation following the orientation of the spinal cord. Plan quality for VMAT is similar to MCO-IMRT, with similar MU for both modalities. Delivery times can be reduced by nominally 25% with VMAT. Copyright © 2015 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
Ghazanfari, Nazanin; Morsch, Marco; Reddel, Stephen W; Liang, Simon X; Phillips, William D
2014-01-01
Muscle-specific kinase (MuSK) autoantibodies from myasthenia gravis patients can block the activation of MuSK in vitro and/or reduce the postsynaptic localization of MuSK. Here we use a mouse model to examine the effects of MuSK autoantibodies upon some key components of the postsynaptic MuSK pathway and upon the regulation of junctional ACh receptor (AChR) numbers. Mice became weak after 14 daily injections of anti-MuSK-positive patient IgG. The intensity and area of AChR staining at the motor endplate was markedly reduced. Pulse-labelling of AChRs revealed an accelerated loss of pre-existing AChRs from postsynaptic AChR clusters without a compensatory increase in incorporation of (newly synthesized) replacement AChRs. Large, postsynaptic AChR clusters were replaced by a constellation of tiny AChR microaggregates. Puncta of AChR staining also appeared in the cytoplasm beneath the endplate. Endplate staining for MuSK, activated Src, rapsyn and AChR were all reduced in intensity. In the tibialis anterior muscle there was also evidence that phosphorylation of the AChR β-subunit-Y390 was reduced at endplates. In contrast, endplate staining for β-dystroglycan (through which rapsyn couples AChR to the synaptic basement membrane) remained intense. The results suggest that anti-MuSK IgG suppresses the endplate density of MuSK, thereby down-regulating MuSK signalling activity and the retention of junctional AChRs locally within the postsynaptic membrane scaffold. PMID:24860174
Heterodimerization of mu and delta opioid receptors: A role in opiate synergy.
Gomes, I; Jordan, B A; Gupta, A; Trapaidze, N; Nagy, V; Devi, L A
2000-11-15
Opiate analgesics are widely used in the treatment of severe pain. Because of their importance in therapy, different strategies have been considered for making opiates more effective while curbing their liability to be abused. Although most opiates exert their analgesic effects primarily via mu opioid receptors, a number of studies have shown that delta receptor-selective drugs can enhance their potency. The molecular basis for these findings has not been elucidated previously. In the present study, we examined whether heterodimerization of mu and delta receptors could account for the cross-modulation previously observed between these two receptors. We find that co-expression of mu and delta receptors in heterologous cells followed by selective immunoprecipitation results in the isolation of mu-delta heterodimers. Treatment of these cells with extremely low doses of certain delta-selective ligands results in a significant increase in the binding of a mu receptor agonist. Similarly, treatment with mu-selective ligands results in a significant increase in the binding of a delta receptor agonist. This robust increase is also seen in SKNSH cells that endogenously express both mu and delta receptors. Furthermore, we find that a delta receptor antagonist enhances both the potency and efficacy of the mu receptor signaling; likewise a mu antagonist enhances the potency and efficacy of the delta receptor signaling. A combination of agonists (mu and delta receptor selective) also synergistically binds and potentiates signaling by activating the mu-delta heterodimer. Taken together, these studies show that heterodimers exhibit distinct ligand binding and signaling characteristics. These findings have important clinical ramifications and may provide new foundations for more effective therapies.
Guidelines for pre-clinical animal and cellular models of MuSK-myasthenia gravis.
Phillips, W D; Christadoss, P; Losen, M; Punga, A R; Shigemoto, K; Verschuuren, J; Vincent, A
2015-08-01
Muscle-specific tyrosine kinase (MuSK) autoantibodies are the hallmark of a form of myasthenia gravis (MG) that can challenge the neurologist and the experimentalist. The clinical disease can be difficult to treat effectively. MuSK autoantibodies affect the neuromuscular junction in several ways. When added to muscle cells in culture, MuSK antibodies disperse acetylcholine receptor clusters. Experimental animals actively immunized with MuSK develop MuSK autoantibodies and muscle weakness. Weakness is associated with reduced postsynaptic acetylcholine receptor numbers, reduced amplitudes of miniature endplate potentials and endplate potentials, and failure of neuromuscular transmission. Similar impairments have been found in mice injected with IgG from MG patients positive for MuSK autoantibody (MuSK-MG). The active and passive models have begun to reveal the mechanisms by which MuSK antibodies disrupt synaptic function at the neuromuscular junction, and should be valuable in developing therapies for MuSK-MG. However, translation into new and improved treatments for patients requires procedures that are not too cumbersome but suitable for examining different aspects of MuSK function and the effects of potential therapies. Study design, conduct and analysis should be carefully considered and transparently reported. Here we review what has been learnt from animal and culture models of MuSK-MG, and offer guidelines for experimental design and conduct of studies, including sample size determination, randomization, outcome parameters and precautions for objective data analysis. These principles may also be relevant to the increasing number of other antibody-mediated diseases that are now recognized. Copyright © 2014 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chinthaka Silva, G.W., E-mail: chinthaka.silva@gmail.com; Kercher, Andrew A., E-mail: rokparent@comcast.net; Hunn, John D., E-mail: hunnjd@ornl.gov
2012-10-15
Samples with five different zirconium carbide compositions (C/Zr molar ratio=0.84, 0.89, 0.95, 1.05, and 1.17) have been fabricated and studied using a variety of experimental techniques. Each sample was zone refined to ensure that the end product was polycrystalline with a grain size of 10-100 {mu}m. It was found that the lattice parameter was largest for the x=0.89 composition and smallest for the x=1.17 total C/Zr composition, but was not linear; this nonlinearity is possibly explained using electron densities calculated using charge flipping technique. Among the five samples, the unit cell of the ZrC{sub 0.89} sample showed the highest electronmore » density, corresponding to the highest carbon incorporation and the largest lattice parameter. The ZrC{sub 0.84} sample showed the lowest carbon incorporation, resulting in a larger number of carbon vacancies and resultant strain. Samples with larger carbon ratios (x=0.95, 1.05, and 1.17) showed a slight decrease in lattice parameter, due to a decrease in electron density. Optical anisotropy measurements suggest that these three samples contained significant amounts of a graphitic carbon phase, not bonded to the Zr atoms. - Graphical abstract: Characterization of zirconium carbides using electron microscopy, optical anisotropy, Auger depth profiles, X-ray diffraction, and electron density calculated by the charge flipping method. Highlights: Black-Right-Pointing-Pointer The lattice parameter variation: ZrC{sub 0.89}>ZrC{sub 0.84}>ZrC{sub 0.95}>ZrC{sub 1.05}>ZrC{sub 1.17}. Black-Right-Pointing-Pointer Surface oxygen with no correlation to the lattice parameter variation. Black-Right-Pointing-Pointer ZrC{sub 0.89} had highest electron densities correspond to highest carbon incorporation. Black-Right-Pointing-Pointer Second highest lattice parameter in ZrC{sub 0.84} due to strain. Black-Right-Pointing-Pointer Unit cell electron density order: ZrC{sub 0.95}>ZrC{sub 1.05}>ZrC{sub 1.17}.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wong, Diane M.; Dagdigian, Paul J
2008-11-01
A comprehensive investigation of laser-induced breakdown spectroscopy (LIBS) at 1.500 {mu}m of residues of six organic compounds (anthracene, caffeine, glucose, 1,3-dinitrobenzene, 2,4-dinitrophenol, and 2,4-dinitrotoluene) on aluminum substrates is presented and compared with LIBS at the Nd:YAG fundamental wavelength of 1.064 {mu}m. The overall emission intensities were found to be smaller at 1.500 {mu}m than at 1.064 {mu}m, and the ratios of C2 and CN molecular emissions to the H atomic emissions were observed to be less. Possible reasons for the observed differences in LIBS at 1.064 {mu}m versus 1.500 {mu}m are discussed.
Combinatorial theory of Macdonald polynomials I: proof of Haglund's formula.
Haglund, J; Haiman, M; Loehr, N
2005-02-22
Haglund recently proposed a combinatorial interpretation of the modified Macdonald polynomials H(mu). We give a combinatorial proof of this conjecture, which establishes the existence and integrality of H(mu). As corollaries, we obtain the cocharge formula of Lascoux and Schutzenberger for Hall-Littlewood polynomials, a formula of Sahi and Knop for Jack's symmetric functions, a generalization of this result to the integral Macdonald polynomials J(mu), a formula for H(mu) in terms of Lascoux-Leclerc-Thibon polynomials, and combinatorial expressions for the Kostka-Macdonald coefficients K(lambda,mu) when mu is a two-column shape.
Relating B_S Mixing and B_S to mu+mu- with New Physics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Golowich, Eugene; /Massachusetts U., Amherst; Hewett, JoAnne
2012-06-11
We perform a study of the standard model fit to the mixing quantities {Delta}M{sub B{sub s}}, and {Delta}{Lambda}{sub B{sub s}}/{Delta}M{sub B{sub s}} in order to bound contributions of new physics (NP) to B{sub s} mixing. We then use this to explore the branching fraction of B{sub s} {yields} {mu}{sup +}{mu}{sup -} in certain models of NP. In most cases, this constrains NP amplitudes for B{sub s} {yields} {mu}{sup +}{mu}{sup -} to lie below the standard model component.
Design and implementation of non-linear image processing functions for CMOS image sensor
NASA Astrophysics Data System (ADS)
Musa, Purnawarman; Sudiro, Sunny A.; Wibowo, Eri P.; Harmanto, Suryadi; Paindavoine, Michel
2012-11-01
Today, solid state image sensors are used in many applications like in mobile phones, video surveillance systems, embedded medical imaging and industrial vision systems. These image sensors require the integration in the focal plane (or near the focal plane) of complex image processing algorithms. Such devices must meet the constraints related to the quality of acquired images, speed and performance of embedded processing, as well as low power consumption. To achieve these objectives, low-level analog processing allows extracting the useful information in the scene directly. For example, edge detection step followed by a local maxima extraction will facilitate the high-level processing like objects pattern recognition in a visual scene. Our goal was to design an intelligent image sensor prototype achieving high-speed image acquisition and non-linear image processing (like local minima and maxima calculations). For this purpose, we present in this article the design and test of a 64×64 pixels image sensor built in a standard CMOS Technology 0.35 μm including non-linear image processing. The architecture of our sensor, named nLiRIC (non-Linear Rapid Image Capture), is based on the implementation of an analog Minima/Maxima Unit. This MMU calculates the minimum and maximum values (non-linear functions), in real time, in a 2×2 pixels neighbourhood. Each MMU needs 52 transistors and the pitch of one pixel is 40×40 mu m. The total area of the 64×64 pixels is 12.5mm2. Our tests have shown the validity of the main functions of our new image sensor like fast image acquisition (10K frames per second), minima/maxima calculations in less then one ms.
ISO observations of obscured Asymptotic Giant Branch stars in the Large Magellanic Cloud
NASA Astrophysics Data System (ADS)
Trams, N. R.; van Loon, J. Th.; Waters, L. B. F. M.; Zijlstra, A. A.; Loup, C.; Whitelock, P. A.; Groenewegen, M. A. T.; Blommaert, J. A. D. L.; Siebenmorgen, R.; Heske, A.; Feast, M. W.
1999-06-01
We present ISO photometric and spectroscopic observations of a sample of 57 bright Asymptotic Giant Branch stars and red supergiants in the Large Magellanic Cloud, selected on the basis of IRAS colours indicative of high mass-loss rates. PHOT-P and PHOT-C photometry at 12, 25 and 60 mu m and CAM photometry at 12 mu m are used in combination with quasi-simultaneous ground-based near-IR photometry to construct colour-colour diagrams for all stars in our sample. PHOT-S and CAM-CVF spectra in the 3 to 14 mu m region are presented for 23 stars. From the colour-colour diagrams and the spectra, we establish the chemical types of the dust around 49 stars in this sample. Many stars have carbon-rich dust. The most luminous carbon star in the Magellanic Clouds has also a (minor) oxygen-rich component. OH/IR stars have silicate absorption with emission wings. The unique dataset presented here allows a detailed study of a representative sample of thermal-pulsing AGB stars with well-determined luminosities. This paper is based on observations with the Infrared Space Observatory (ISO). ISO is an ESA project with instruments funded by ESA member states (especially the PI countries: France, Germany, The Netherlands and the United Kingdom) and with the participation of ISAS and NASA.
Dosimetric comparison between 10MV-FFF and 6MV-FFF for lung SBRT
NASA Astrophysics Data System (ADS)
Durmus, I. F.; Atalay, E. D.
2017-02-01
Plans were prepared by using same non-coplanar fields and physical parameters in 6MV-FFF and 10MV-FFF energies for fourteen lung Stereotactic Body Radio Therapy (SBRT) patients. In two plans which have different energies, critic organ doses, PTV doses, quality of plans (Gradient Index (GI), Homogeneity Index (HI), Conformity Index (CI)) and Monitor Unit (MU) values were compared. Quality controls were performed with 2D-Array Iba MatriXX Evolution® dosimetry system for each plans. As a results, plan with 6MV-FFF energy give better results in terms of CI and GI values. In this way, when more conformal dose distributions were provided, there was a rapid dose decrease at out of target volume. Lower MU values were obtained in plans which was prepared with 10MV-FFF energy. In plan with 10MV-FFF energy lower MU values are obtained. Lower values in heart and spinal cord doses are founded and better results are obtained in Body and Ipsa-Lung V5, V10, V20 values with 6MV-FFF energies. When differences were very small in volume which were taken low dose (V5), these differences increased in volume which were taken high dose (V20). High dose rates can be reached by both two unfiltered energies and can be used in lung SBRT.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Volkringer, Christophe; Loiseau, Thierry
2006-05-25
A new indium trimesate In{sub 12}O(OH){sub 12}({l_brace}OH{r_brace}{sub 4},{l_brace}H{sub 2}O{r_brace}{sub 5})[btc]{sub 6}.{approx}31H{sub 2}O, called MIL-96 (btc = 1,3,5-benzenetricarboxylate or trimesate species) was hydrothermally synthesized under mild condition (210 deg. C, 5 h) in the presence of trimethyl 1,3,5-benzenetricarboxylate in water and characterized by single-crystal X-ray diffraction technique. The MIL-96 (In) structure exhibits a three-dimensional metal-organic framework containing isolated trinuclear {mu} {sub 3}-oxo-bridged indium clusters and infinite chains of InO{sub 4}(OH){sub 2} and InO{sub 2}(OH){sub 3}(H{sub 2}O) octahedra generating a hexagonal network based on 18-membered ring. The two types of indium entities are connected to each other through the trimesate species whichmore » induce corrugated chains of indium octahedra, linked via {mu} {sub 2}-hydroxo bonds with the specific -cis-cis-trans- sequence. The 3D framework of MIL-96 reveals three kind of cavities (two of them have estimated {approx} 400 A{sup 3} volumes), in which are encapsulated free water molecules. The latter species are removed upon heating at 150 deg. C.« less
NASA Astrophysics Data System (ADS)
Wilke, K.; Stickel, M.; Haas, M.; Herbstmeier, U.; Klaas, U.; Lemke, D.
2003-04-01
The ISOPHOT experiment onboard the ISO satellite generated a complete view of the Small Magellanic Cloud (SMC) at 170 mu m with 1.5 arcmin resolution. The map is analysed using an automated photometry program enabling accurate photometric characterization of the far infrared (FIR) emitting regions. An integrated FIR luminosity of 8.5x 107 Lsun is obtained, leading to a star formation rate of SFRFIR=0.015 Msun/yr. With an average dust temperature of
Measurements of OC and EC in coarse particulate matter in the southeastern United States
DOE Office of Scientific and Technical Information (OSTI.GOV)
Edgerton, E.S.; Casuccio, G.S.; Saylor, R.D.
The organic carbon (OC) and elemental carbon (EC) content of filter-based, 24-hr integrated particulate matter with aerodynamic diameters between 2.5 and 10 {mu}m (PM10-2.5) was measured at two urban and two rural locations in the southeastern United States. On average, total carbon (OC + EC) comprised approximately 30% of PM10-2.5 mass at these four sites. Carbonate carbon was measured on a subset of samples from three sites and was found to be undetectable at a rural site in central Alabama, less than 2% of PM10-2.5 at an urban site in Georgia, and less than 10% of PM10-2.5 at an urban-industrialmore » site in Alabama. Manual scanning electron microscopy (SEM) and computer-controlled SEM (CCSEM) along with energy dispersive X-ray spectroscopy (EDS) were used to identify individual carbonaceous particles in a selected subset of samples collected at one rural site and one urban-industrial site in Alabama. CCSEM results showed that biological material (e.g., fungal spores, pollen, and vegetative detritus) accounted for 60-70% of the carbonaceous mass in PM10-2.5 samples with concentrations in the range of 2-16 {mu}g/m{sup 3}. Samples with higher PM10-2.5 concentrations (25-42 {mu}g/m{sup 3}) at the urban-industrial site were found by manual SEM to have significant amounts of unidentified carbonaceous material, likely originating from local industrial activities. Both filter-based OC and EC concentrations and SEM-identified biological material tended to have higher concentrations during warmer months. Upper limits for organic mass (OM) to OC ratios (OM/OC) are estimated for PM10-2.5 samples at 2.1 for urban sites and 2.6-2.7 for rural sites. 40 refs., 12 figs., 5 tabs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fallone, B; Keyvanloo, A; Burke, B
Purpose: To quantify increase in entrance skin-dose due to magnetic fields of the Alberta longitudinal linac-MR by examining the effect of radiation energy and flattening filter, using Monte Carlo calculations and accurate 3-D models of the magnetic field. Methods: The 3-D magnetic fields generated by the bi-planar Linac-MR are calculated with FEM using Opera-3D. BEAMnrc simulates the particle phase-space in the presence of the rapidly decaying fringe field of 0.5T MRI assembled with a Varian 600C linac with an isocentre distance of 130 cm for 6 MV and 10 MV beams. Skin doses are calculated at an average depth ofmore » 70 µm using DOSXYZnrc with varying SSDs and field sizes. Furthermore, flattening filters are reshaped to compensate for the significant drop in dose rate due to increased SAD of 130 cm and skin-doses are evaluated. Results: The confinement effect of the MRI fringe field on the contaminant electrons is minimal. For SSDs of 100 – 120 cm the increase in skin dose is ∼6% – 19% and ∼1% – 9% for the 6 and 10 MV beams, respectively. For 6MV, skin dose increases from ∼10.5% to 1.5%. for field-size increases of 5×5 cm2 to 20×20 cm2. For 10 MV, skin dose increases by ∼6% for a 5×5 cm2 field, and decreases by ∼1.5% for a 20×20 cm2 field. The reshaped flattening filter increases the dose rate from 355 MU/min to 529 MU/min (6 MV) or 604 MU/min (10 MV), while the skin-dose increases by only an additional ∼2.6% (all percent increases in skin dose are relative to Dmax). Conclusion: There is minimal increase in the entrance skin dose and minimal/no decrease in the dose rate of the Alberta longitudinal linac-MR system. There is even lower skin-dose increase at 10 MV. Funding: Alberta Innovates - Health Solutions (AIHS) Conflict of Interest: Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta bi-planar linac MR for commercialization)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pavel, Nicolaie; Luenstedt, Kai; Petermann, Klaus
2007-12-01
The laser performances of the 1.06 {mu}m 4F3/2 --> 4I11/2 four-level transition and of the 0.9 {mu}m 4F3/2 --> I9/24 quasi-three-level transition were investigated using multipass pumped Nd-based media in thin-disk geometry. When pumping at 0.81 {mu}m into the 4F5/2 level, continuous-wave laser operation was obtained with powers in excess of 10 W at 1.06 {mu}m, in the multiwatt region at 0.91 {mu}m in Nd:YVO4 and Nd:GdVO4, and at 0.95 {mu}m in Nd:YAG. Intracavity frequency-doubled Nd:YVO4 thin-disk lasers with output powers of 6.4 W at 532 nm and of 1.6 W at 457 nm were realized at this pumping wavelength.more » The pumping at 0.88 {mu}m, which is directed into the 4F3/2 emitting level, was also employed, and Nd:YVO4 and Nd:GdVO4 thin-disk lasers with {approx}9 W output power at 1.06 {mu}m and visible laser radiation at 0.53 {mu}m with output power in excess of 4 W were realized. Frequency-doubled Nd:vanadate thin-disk lasers with deep blue emission at 0.46 {mu}m were obtained under pumping directly into the 4F3/2 emitting level.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frank, Sabrina N.; Singer, Christoph; Sures, Bernd
The effects of different exposure concentrations of palladium (Pd) on relative metallothionein (MT) response and bioaccumulation were investigated in zebra mussels (Dreissena polymorpha). The mussels were exposed to 0.05, 5, 50, and 500 {mu}g/L Pd{sup 2+} for 10 weeks under controlled temperature and fasting conditions. Relative MT contents were assessed by a modified Ag-saturation method, which allows to discriminate between MT bound to Pd (Pd-MT) and MT bound to unidentified metals (Ag-MT). Determination of metal contents resulted from atomic absorption spectrometry following a microwave digestion. For unexposed mussels and mussels exposed to 0.05 {mu}g/L Pd no metal accumulation could bemore » detected. All other exposure concentrations resulted in detectable Pd accumulation in mussels with final tissue concentrations of 96 {mu}g/g (500 {mu}g/L), 45 {mu}g/g (50 {mu}g/L), and 9 {mu}g/g (5 {mu}g/L). Compared with initial levels Pd-MT concentrations at the end of the exposure period were 600 (500 {mu}g/L), 160 (50 {mu}g/L), and 27 (5 {mu}g/L) times higher. These results show that an increase in MTs in D. polymorpha already occurs at relatively low aqueous Pd concentrations indicating that there is the need for detoxification of Pd in the mussel. Furthermore, correlations between Ag-MT and Pd accumulation indicate that higher exposure concentrations are associated with adverse effects on the mussels. Thus, harmful effects of chronic Pd exposure of organisms even in lowest concentrations cannot be excluded in the environment.« less
Netherton, Tucker; Li, Yuting; Nitsch, Paige; Shaitelman, Simona; Balter, Peter; Gao, Song; Klopp, Ann; Muruganandham, Manickam; Court, Laurence
2018-06-01
Using a new linear accelerator with high dose rate (800 MU/min), fast MLC motions (5.0 cm/s), fast gantry rotation (15 s/rotation), and 1 cm wide MLCs, we aimed to quantify the effects of complexity, arc number, and fractionation on interplay for breast and lung treatments under target motion. To study lung interplay, eight VMAT plans (1-6 arcs) and four-nine-field sliding-window IMRT plans varying in complexity were created. For the breast plans, four-four-field sliding-window IMRT plans were created. Using the Halcyon 1.0 linear accelerator, each plan was delivered five times each under sinusoidal breathing motion to a phantom with 20 implanted MOSFET detectors; MOSFET dose (cGy), delivery time, and MU/cGy values were recorded. Maximum and mean dose deviations were calculated from MOSFET data. The number of MOSFETs with at least 19 of 20 detectors agreeing with their expected dose within 5% per fraction was calculated across 10 6 iterations to model dose deviation as function of fraction number for all plan variants. To put interplay plans into clinical context, additional IMRT and VMAT plans were created and delivered for the sites of head and neck, prostate, whole brain, breast, pelvis, and lung. Average modulation and interplay effect were compared to those from conventional linear accelerators, as reported from previous studies. The mean beam modulation for plans created for the Halcyon 1.0 linear accelerator was 2.9 MU/cGy (two- to four-field IMRT breast plans), 6.2 MU/cGy (at least five-field IMRT), and 3.6 MU/cGy (four-arc VMAT). To achieve treatment plan objectives, Halcyon 1.0 VMAT plans require more arcs and modulation than VMAT on conventional linear accelerators. Maximum and mean dose deviations increased with increasing plan complexity under tumor motion for breast and lung treatments. Concerning VMAT plans under motion, maximum, and mean dose deviations were higher for one arc than for two arcs regardless of plan complexity. For plan variants with maximum dose deviations greater than 3.7%, dose deviation as a function of fraction number was protracted. For treatments on the Halcyon 1.0 linear accelerator, the convergence of dose deviation with fraction number happened more slowly than reported for conventional linear accelerators. However, if plan complexity is reduced for IMRT and if tumor motion is less than ~10-mm, interplay is greatly reduced. To minimize dose deviations across multiple fractions for dynamic targets, we recommend limiting treatment plan complexity and avoiding one-arc VMAT on the Halcyon 1.0 linear accelerator when interplay is a concern. © 2018 American Association of Physicists in Medicine.
Magnetic order and electronic structure of 5d 3 double perovskite Sr 2ScOsO 6
Taylor, A. E.; Morrow, R.; Singh, D. J.; ...
2015-03-01
The magnetic susceptibility, crystal and magnetic structures, and electronic structure of double perovskite Sr 2ScOsO 6 are reported. Using both neutron and x-ray powder diffraction we find that the crystal structure is monoclinic P21/n from 3.5 to 300 K. Magnetization measurements indicate an antiferromagnetic transition at TN=92 K, one of the highest transition temperatures of any double perovskite hosting only one magnetic ion. Type I antiferromagnetic order is determined by neutron powder diffraction, with an Os moment of only 1.6(1) muB, close to half the spin-only value for a crystal field split 5d electron state with t2g^3 ground state. Densitymore » functional calculations show that this reduction is largely the result of strong Os-O hybridization, with spin-orbit coupling responsible for only a ~0.1 muB reduction in the moment.« less
Time-Resolved Kinetic Chirped-Pulse Rotational Spectroscopy in a Room-Temperature Flow Reactor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zaleski, Daniel P.; Harding, Lawrence B.; Klippenstein, Stephen J.
Chirped-pulse Fourier transform millimeter-wave spectroscopy is a potentially powerful tool for studying chemical reaction dynamics and kinetics. Branching ratios of multiple reaction products and intermediates can be measured with unprecedented chemical specificity; molecular isomers, conformers, and vibrational states have distinct rotational spectra. Here we demonstrate chirped-pulse spectroscopy of vinyl cyanide photoproducts in a flow tube reactor at ambient temperature of 295 K and pressures of 1-10 mu bar. This in situ and time-resolved experiment illustrates the utility of this novel approach to investigating chemical reaction dynamics and kinetics. Following 193 nm photodissociation of CH2CHCN, we observe rotational relaxation of energizedmore » HCN, HNC, and HCCCN photoproducts with 10 mu s time resolution and sample the vibrational population distribution of HCCCN. The experimental branching ratio HCN/HCCCN is compared with a model based on RRKM theory using high-level ab initio calculations, which were in turn validated by comparisons to Active Thermochemical Tables enthalpies.« less
Time-Resolved Kinetic Chirped-Pulse Rotational Spectroscopy in a Room-Temperature Flow Reactor
Zaleski, Daniel P.; Harding, Lawrence B.; Klippenstein, Stephen J.; ...
2017-12-01
Chirped-pulse Fourier transform millimeter-wave spectroscopy is a potentially powerful tool for studying chemical reaction dynamics and kinetics. Branching ratios of multiple reaction products and intermediates can be measured with unprecedented chemical specificity; molecular isomers, conformers, and vibrational states have distinct rotational spectra. Here we demonstrate chirped-pulse spectroscopy of vinyl cyanide photoproducts in a flow tube reactor at ambient temperature of 295 K and pressures of 1-10 mu bar. This in situ and time-resolved experiment illustrates the utility of this novel approach to investigating chemical reaction dynamics and kinetics. Following 193 nm photodissociation of CH2CHCN, we observe rotational relaxation of energizedmore » HCN, HNC, and HCCCN photoproducts with 10 mu s time resolution and sample the vibrational population distribution of HCCCN. The experimental branching ratio HCN/HCCCN is compared with a model based on RRKM theory using high-level ab initio calculations, which were in turn validated by comparisons to Active Thermochemical Tables enthalpies.« less
Group III-nitride thin films grown using MBE and bismuth
Kisielowski, Christian K.; Rubin, Michael
2002-01-01
The present invention comprises growing gallium nitride films in the presence of bismuth using MBE at temperatures of about 1000 K or less. The present invention further comprises the gallium nitride films fabricated using the inventive fabrication method. The inventive films may be doped with magnesium or other dopants. The gallium nitride films were grown on sapphire substrates using a hollow anode Constricted Glow Discharge nitrogen plasma source. When bismuth was used as a surfactant, two-dimensional gallium nitride crystal sizes ranging between 10 .mu.m and 20 .mu.m were observed. This is 20 to 40 times larger than crystal sizes observed when GaN films were grown under similar circumstances but without bismuth. It is thought that the observed increase in crystal size is due bismuth inducing an increased surface diffusion coefficient for gallium. The calculated value of 4.7.times.10.sup.-7 cm.sup.2 /sec. reveals a virtual substrate temperature of 1258 K which is 260 degrees higher than the actual one.
Group III-nitride thin films grown using MBE and bismuth
Kisielowski, Christian K.; Rubin, Michael
2000-01-01
The present invention comprises growing gallium nitride films in the presence of bismuth using MBE at temperatures of about 1000 K or less. The present invention further comprises the gallium nitride films fabricated using the inventive fabrication method. The inventive films may be doped with magnesium or other dopants. The gallium nitride films were grown on sapphire substrates using a hollow anode Constricted Glow Discharge nitrogen plasma source. When bismuth was used as a surfactant, two-dimensional gallium nitride crystal sizes ranging between 10 .mu.m and 20 .mu.m were observed. This is 20 to 40 times larger than crystal sizes observed when GaN films were grown under similar circumstances but without bismuth. It is thought that the observed increase in crystal size is due bismuth inducing an increased surface diffusion coefficient for gallium. The calculated value of 4.7.times.10.sup.-7 cm.sup.2 /sec. reveals a virtual substrate temperature of 1258 K which is 260 degrees higher than the actual one.
Using Phase Space Density Profiles to Investigate the Radiation Belt Seed Population
NASA Astrophysics Data System (ADS)
Boyd, A. J.; Spence, H.; Reeves, G. D.; Blake, J. B.; Fennell, J. F.; Claudepierre, S. G.; Turner, D. L.
2013-12-01
It is believed that particles with energies of 100s of keV play a critical role in the acceleration of electrons within the radiation belt. Through wave particle interactions, these so called 'seed electrons' can be accelerated up to energies greater than 1 MeV. Using data from the MagEIS (Magnetic Electron Ion Spectrometer) Instrument onboard the Van Allen Probes we calculate phase space density within the radiation belts over a wide range of mu and K values. These phase space density profiles are combined with those from THEMIS, in order to see how the phase space density evolves over a large range of L*. In this presentation we examine how the seed electron population evolves in both time and L* during acceleration events. Comparing this to the evolution of the higher mu electron population allows us to determine what role the seed electrons played in the acceleration process. Finally, we compare several of these storms to examine the importance of the seed population to the acceleration process.
Analysis of time-resolved argon line spectra from OMEGA direct-drive implosions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Florido, R.; Nagayama, T.; Mancini, R. C.
2008-10-15
We discuss the observation and data analysis of argon K-shell line spectra from argon-doped deuterium-filled OMEGA direct-drive implosion cores based on data recorded with two streaked crystal spectrometers. The targets were 870 {mu}m in diameter, 27 {mu}m wall thickness plastic shells filled with 20 atm of deuterium gas, and a tracer amount of argon for diagnostic purposes. The argon K-shell line spectrum is primarily emitted at the collapse of the implosion and its analysis provides a spectroscopic diagnostic of the core implosion conditions. The observed spectra includes the He{alpha}, Ly{alpha}, He{beta}, He{gamma}, Ly{beta}, and Ly{gamma} line emissions and their associatedmore » He- and Li-like satellites thus covering a broad photon energy range from 3100 to 4200 eV with a spectral resolution power of approximately 500. The data analysis relies on detailed atomic and spectral models that take into account nonequilibrium collisional-radiative atomic kinetics, Stark-broadened line shapes, and radiation transport calculations.« less
Seismic evidence of Messinian salt in opposite margins of West Mediterranean
NASA Astrophysics Data System (ADS)
Mocnik, Arianna; Camerlenghi, Angelo; Del Ben, Anna; Geletti, Riccardo; Wardell, Nigel; Zgur, Fabrizio
2015-04-01
The post drift Messinian Salinity Crisis (MSC) affected the whole Mediterranean basin, with deposition of evaporitic sequences in the deep basins, in the lower continental slopes, and in several shallower marginal basins; usually, in the continental margins, the MSC originated noticeable erosional truncations that locally cause important hiatuses in the pre-Messinian sequences, covered by the Plio-Quaternary sediments. In this work we focus on the MSC seismic signature of two new seismic datasets acquired in 2010 (West Sardinia offshore) and in 2012 (within the Eurofleet project SALTFLU in the South Balearic continental margin and the northern Algero abyssal plain). The "Messinian trilogy" recognized in the West-Mediterranean abyssal plain, is characterized by different seismic facies: the Lower evaporite Unit (LU), the salt Mobile Unit (MU) and the Upper evaporite mainly gypsiferous Unit (UU). Both seismic datasets show the presence of the Messinian trilogy also if the LU is not always clearly interpretable due to the strong seismic signal absorption by the halite layers; the salt thickness of the MU is similar in both the basins as also the thickness and stratigraphy of the UU. The Upper Unit (UU) is made up of a well reflecting package of about 10 reflectors, partially deformed by salt tectonic and characterized by a thin transparent layer that we interpreted as salt sequence inner the shallower part of the UU. Below the stratified UU, the MU exhibits a transparent layer in the deep basin and also on the foot of the slope, where a negative reflector, related to the high interval velocity of salt, marks its base. The halokinetic processes are not homogeneously distributed in the region, forming a great number of diapirs on the foot of the slope (due to the pression of the slided sediments) and giant domes toward the deep basin (due to the higher thickness of the Plio-quaternary sediments). This distribution seems to be related to the amount of salt and of the sedimentary cover. During the MSC the margins of the West Mediterranean Sea seem to be involved in some tectonic events probably connected to reactivation of normal faults and to the fast variation of the water load related to sea level fluctuations. The absence of calibrating boreholes in the deep Mediterranean basins and the hard penetration of seismic energy below the evaporitic layers, represent a limit for the knowledge of the geological evolution of the basins; the interpretation of the presented datasets could be a contribution to the comprehension of the evaporitic deposition and early-stage salt deformation during the MSC in the Mediterranean sea.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hershkovitz, N.; Oren, A.; Cohen, Y.
The drought-resistant cyanobacteria Phormidium autumnale, strain LPP{sub 4}, and a Chroococcidiopsis sp. accumulated trehalose, sucrose, and both trehalose and sucrose, respectively, in response to matric water stress. Accumulated sugar concentrations reached values of up to 6.2 {mu}g of trehalose per {mu}g of chlorophyll in P. autumnale, 6.9 {mu}g of sucrose per {mu}g of chlorophyll in LPP{sub 4}, and 4.1 {mu}g of sucrose and 3.2 {mu}g of trehalose per {mu}g of chlorophyll in the Chroococcidiopsis sp. The same sugars were accumulated by these cyanobacteria in similar concentrations under osmotic water stress. Cyanobacteria that did not show drought resistance (Plectonema boryanum andmore » Synechococcus strain PCC 7942) did not accumulate significant amounts of sugars when matric water stress was applied.« less
Cai, Ronglin; Guan, Yuanyuan; Wu, Hongli; Xu, Chunsheng; Li, Chuanfu; Hu, Ling; Shen, Guoming
2018-04-12
To observe the regional homogeneity (ReHo) of resting-state brain function in the healthy subjects of gastric distention treated with acupuncture at the back- shu and front- mu points of the stomach, Weishu (BL 21) and Zhongwan (CV 12) and the correlation with gastric motility so as to explore the mechanism on the central integration of the front- mu and back- shu points of the stomach. The crossover test design was adopted. Twenty-four healthy subjects were assigned to a Weishu group, a Zhongwan group and a combined-point group separately, 8 cases in each one in each of the three times. Totally, 24 subjects were included in each group. Under the water load condition, the subjects received acupuncture at Weishu (BL 21), Zhongwan (CV 12) and the combined Weishu (BL 21) and Zhongwan (CV 12). Before and after each acupuncture, the resting-state brain functional magnetic resonance imaging (fMRI) scan and electrogastrogram (EGG) test were applied. The ReHo value was calculated in the collected fMRI imaging data. The changes in ReHo values were analyzed and compared before and after acupuncture in each group, as well as among the groups. The gastric motility was analyzed before and after acupuncture. Additionally, the correlative analysis was conducted between the gastric motility and ReHo changes before and after acupuncture. (1) After acupuncture, EGG amplitudes in the subjects of each group were lower remarkably as compared with those before acupuncture (all P <0.01). The EGG frequencies were not different significantly as compared with those before acupuncture (all P >0.05). The EGG amplitudes in the Weishu group and the Zhongwan group were higher than those in the combined-point group (both P <0.05). (2) As compared with the conditions before acupuncture, acupuncture at the combined front- mu and the back- shu points as well as Weishu (BL 21) and Zhongwan (CV 12) separately all induced the changes in the brain ReHo. Acupuncture at the combined front- mu and the back- shu points significantly increased Reho values in the right inferior temporal gyrus, the left thalamus, the precuneus and the posterior cingulate gyrus (all P <0.05) and remarkably reduced the ReHo values in the the middle temporal gyrus of the right temporal pole, sulcus calcarinus and precuneus (all P <0.05). Compared with the single point groups, acupuncture at the combined front- mu and the back- shu points induced the increase of ReHo value in the posterior cingulate gyrus and the decrease of ReHo in the temporal pole (all P <0.05). (3) The correlative analysis showed that the changes in the ReHo values in the posterior cingulate gyrus, the thalamus and the precuneus were positively correlated to the changes of the gastric motility amplitudes. The changes in the ReHo values in the temporal pole was negatively correlated to the changes of the gastric motility amplitudes. Acupuncture at the combined back- shu and front- mu points of the stomach, as well as acupuncture at single Weishu (BL 21) and Zhongwan (CV 12) induce the ReHo changes in the different brain regions. Acupuncture at the combined back- shu and front- mu points of the stomach may induce the ReHo changes in some new brain regions as compared with the acupuncture at the single point. The thalamus, the posterior cingulate gyrus and the precuneus may be the the important integrated brain regions for acupuncture at the back- shu and the front- mu points in regulating the gastric motility. The effects of acupuncture at the back- shu and the front- mu points for the regulation of the gastric motility are closely related to the thalamus, the limbic system and the default network of the brain regions.
Jones, Leigh F; Rajaraman, Gopalan; Brockman, Jonathon; Murugesu, Muralee; Sanudo, E Carolina; Raftery, Jim; Teat, Simon J; Wernsdorfer, Wolfgang; Christou, George; Brechin, Euan K; Collison, David
2004-10-11
The syntheses, structures and magnetic properties of three new MnIII clusters, [Mn26O17(OH)8(OMe)4F10(bta)22(MeOH)14(H2O)2] (1), [Mn(0O6(OH)2(bta)8(py)8F8] (2) and [NHEt3]2[Mn3O(bta)6F3] (3), are reported (bta=anion of benzotriazole), thereby demonstrating the utility of MnF3 as a new synthon in Mn cluster chemistry. The "melt" reaction (100 degrees C) between MnF(3) and benzotriazole (btaH, C6H5N3) under an inert atmosphere, followed by dissolution in MeOH produces the cluster [Mn26O17(OH)8(OMe)4F10(bta)22(MeOH)14(H2O)2] (1) after two weeks. Complex 1 crystallizes in the triclinic space group P1, and consists of a complicated array of metal tetrahedra linked by mu3-O2- ions, mu3- and mu2-OH- ions, mu2-MeO- ions and mu2-bta- ligands. The "simpler" reaction between MnF3 and btaH in boiling MeOH (50 degrees C) also produces complex 1. If this reaction is repeated in the presence of pyridine, the decametallic complex [Mn10O6(OH)2(bta)8(py)8F8] (2) is produced. Complex 2 crystallizes in the triclinic space group P1 and consists of a "supertetrahedral" [Mn(III)10] core bridged by six mu3-O2- ions, two mu3-OH- ions, four mu2-F- ions and eight mu2-bta- ions. The replacement of pyridine by triethylamine in the same reaction scheme produces the trimetallic species [NHEt3]2[Mn3O(bta)6F3] (3). Complex 3 crystallises in the monoclinic space group P2(1)/c and has a structure analogous to that of the basic metal carboxylates of general formula [M3O(RCO2)6L3]0/+, which consists of an oxo-centred metal triangle with mu2-bta- ligands bridging each edge of the triangle and the fluoride ions acting as the terminal ligands. DC magnetic susceptibility measurements in the 300-1.8 K and 0.1-7 T ranges were investigated for all three complexes. For each, the value of chi(M)T decreases with decreasing temperatures; this indicates the presence of dominant antiferromagnetic exchange interactions in 1-3. For complex 1, the low-temperature value of chi(M)T is 10 cm(3) K mol(-1) and fitting of the magnetisation data gives S=4, g=2.0 and D=-0.90 cm(-1). For complex 2, the value of chi(M)T falls to a value of approximately 5.0 cm(3) K mol(-1) at 1.8 K, which is consistent with a small spin ground state. For the triangular complex 3, the best fit to the experimental chi(M)T versus T data was obtained for the following parameters: Ja = -5.01 cm(-1), Jb = +9.16 cm(-1) and g=2.00, resulting in an S=2 spin ground state. DFT calculations on 3, however, suggest an S=1 or S=0 ground state with J(a)=-2.95 cm(-1) and J(b)=-2.12 cm(-1). AC susceptibility measurements performed on 1 in the 1.8-4.00 K range show the presence of out-of-phase AC susceptibility signals, but no peaks. Low-temperature single-crystal studies performed on 1 on an array of micro-SQUIDS show the time- and temperature-dependent hysteresis loops indicative of single-molecule magnetism behaviour.
Nibert, M L; Fields, B N
1992-01-01
Penetration of a cell membrane as an early event in infection of cells by mammalian reoviruses appears to require a particular type of viral particle, the infectious subvirion particle (ISVP), which is generated from an intact virion by proteolytic cleavage of the outer capsid proteins sigma 3 and mu 1/mu 1C. Characterizations of the structural components and properties of ISVPs are thus relevant to attempts to understand the mechanism of penetration by reoviruses. In this study, a novel, approximately 13-kDa carboxy-terminal fragment (given the name phi) was found to be generated from protein mu 1/mu 1C during in vitro treatments of virions with trypsin or chymotrypsin to yield ISVPs. With trypsin treatment, both the carboxy-terminal fragment phi and the amino-terminal fragment mu 1 delta/delta were shown to be generated and to remain attached to ISVPs in stoichiometric quantities. Sites of protease cleavage were identified in the deduced amino acid sequence of mu 1 by determining the amino-terminal sequences of phi proteins: trypsin cleaves between arginine 584 and isoleucine 585, and chymotrypsin cleaves between tyrosine 581 and glycine 582. Findings in this study indicate that sequences in the phi portion of mu 1/mu 1C may participate in the unique functions attributed to ISVPs. Notably, the delta-phi cleavage junction was predicted to be flanked by a pair of long amphipathic alpha-helices. These amphipathic alpha-helices, together with the myristoyl group at the extreme amino terminus of mu 1/mu 1N, are proposed to interact directly with the lipid bilayer of a cell membrane during penetration by mammalian reoviruses. Images PMID:1328674
Ghazanfari, Nazanin; Morsch, Marco; Reddel, Stephen W; Liang, Simon X; Phillips, William D
2014-07-01
Muscle-specific kinase (MuSK) autoantibodies from myasthenia gravis patients can block the activation of MuSK in vitro and/or reduce the postsynaptic localization of MuSK. Here we use a mouse model to examine the effects of MuSK autoantibodies upon some key components of the postsynaptic MuSK pathway and upon the regulation of junctional ACh receptor (AChR) numbers. Mice became weak after 14 daily injections of anti-MuSK-positive patient IgG. The intensity and area of AChR staining at the motor endplate was markedly reduced. Pulse-labelling of AChRs revealed an accelerated loss of pre-existing AChRs from postsynaptic AChR clusters without a compensatory increase in incorporation of (newly synthesized) replacement AChRs. Large, postsynaptic AChR clusters were replaced by a constellation of tiny AChR microaggregates. Puncta of AChR staining also appeared in the cytoplasm beneath the endplate. Endplate staining for MuSK, activated Src, rapsyn and AChR were all reduced in intensity. In the tibialis anterior muscle there was also evidence that phosphorylation of the AChR β-subunit-Y390 was reduced at endplates. In contrast, endplate staining for β-dystroglycan (through which rapsyn couples AChR to the synaptic basement membrane) remained intense. The results suggest that anti-MuSK IgG suppresses the endplate density of MuSK, thereby down-regulating MuSK signalling activity and the retention of junctional AChRs locally within the postsynaptic membrane scaffold. © 2014 The Authors. The Journal of Physiology © 2014 The Physiological Society.
Comparison of two immunoradiometric assays for serum thyrotropin
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scheinin, B.; Drew, H.; La France, N.
1985-05-01
An ultra-sensitive TSH assay capable of detecting subnormal TSH levels would be useful in confirming suppressed pituitary function as seen in hyperthyroidism. Two sensitive immunoradiometric TSH assays (IRMA's) were studied to determine how well they distinguished thyrotoxic patients from normal subjects. Serono Diagnostics' method employs three monoclonal antibodies specific for different regions of the TSH molecule with a minimum detectable dose (MDD) limit of 0.1 ..mu..IU/ml. Precision studies using a low TSH control in the 1.8 ..mu..IU/ml range gave CV's of 15.0%. Boots-Celltech Diagnostics method is a two site IRMA using two monoclonal antibodies. The MDD limit is 0.05 ..mu..IU/mlmore » with precision CV's of 29.3% at a TSH control range of 0.62 ..mu..IU/ml. In 24 chemically thyrotoxic patients, the mean serum TSH concentration was significantly lower than in the normal control subjects: for Serono, 0.19 ..mu..IU/ml vs. 2.34 ..mu..IU/ml and for Boots Celltech, 0.18 IU/ml vs 2.06 ..mu..IU/ml. The range of TSH was 0 to 0.5 ..mu..IU/ml in thyrotoxic patients using Serono with the exception of one patient having a TSH value of 0.8 ..mu..IU/ml. The normal range was 0.6 to 6.0 ..mu..IU/ml. For Boots Celltech the thyrotoxic range was 0 to 0.2 ..mu..IU/ml with that same thyrotoxic patient giving a TSH value of 0.7 ..mu..IU/ml with a normal range of 0.6 to 5.0 IU/ml. Serum TSH measurements using both procedures are highly sensitive for distinguishing thyrotoxic patients from normal subjects and are useful to confirm suppressed pituitary function.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hansen, Anders T., E-mail: andehans@rm.dk; Lukacova, Slavka; Lassen-Ramshad, Yasmin
2015-01-01
When standard conformal x-ray technique for craniospinal irradiation is used, it is a challenge to achieve satisfactory dose coverage of the target including the area of the cribriform plate, while sparing organs at risk. We present a new intensity-modulated radiation therapy (IMRT), noncoplanar technique, for delivering irradiation to the cranial part and compare it with 3 other techniques and previously published results. A total of 13 patients who had previously received craniospinal irradiation with standard conformal x-ray technique were reviewed. New treatment plans were generated for each patient using the noncoplanar IMRT-based technique, a coplanar IMRT-based technique, and a coplanarmore » volumetric-modulated arch therapy (VMAT) technique. Dosimetry data for all patients were compared with the corresponding data from the conventional treatment plans. The new noncoplanar IMRT technique substantially reduced the mean dose to organs at risk compared with the standard radiation technique. The 2 other coplanar techniques also reduced the mean dose to some of the critical organs. However, this reduction was not as substantial as the reduction obtained by the noncoplanar technique. Furthermore, compared with the standard technique, the IMRT techniques reduced the total calculated radiation dose that was delivered to the normal tissue, whereas the VMAT technique increased this dose. Additionally, the coverage of the target was significantly improved by the noncoplanar IMRT technique. Compared with the standard technique, the coplanar IMRT and the VMAT technique did not improve the coverage of the target significantly. All the new planning techniques increased the number of monitor units (MU) used—the noncoplanar IMRT technique by 99%, the coplanar IMRT technique by 122%, and the VMAT technique by 26%—causing concern for leak radiation. The noncoplanar IMRT technique covered the target better and decreased doses to organs at risk compared with the other techniques. All the new techniques increased the number of MU compared with the standard technique.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Henzen, D; Schmidhalter, D; Volken, W
Purpose: Radiation protection regulatory differentiates between primary and scatter radiation. Whereas for conventional clinical linear accelerators the solid angle for primary radiation is planar, the Cyberknife (Accuray Inc., Sunnyvale, CA) may point its beam in all spatial directions. In order to be able to judge on radiation protection calculations for a Cyberknife-M6 vault, the direction distribution for delivered plans was evaluated based on clinical experiences. Methods: The log-files of 121 delivered patient treatment plans were exported, divided into cranial and extra-cranial treatments and the delivered monitor units (MU) together with the corresponding beam directions were analyzed. This MU-weighted spatial distributionmore » was then projected to a 9.5 × 5.9 × 3.9 m{sup 3} vault, generating an “intensity map” using a binning of 50 × 50 cm{sup 2}. The factor of direction (FOD) is reported as a fraction of the total applied MUs to the walls, ceiling and floor in the perspective of a patient lying in head-first-supine position on the couch. In this study, the term intFOD refers to the integral FOD and maxFOD refers to the maximal FOD for a single bin. Results: For all kind of treatments and collimators, intFOD and maxFOD for the wall behind the patient’s head is 0.0. The intFOD for the floor varies between 0.65 and 0.74. For the ceiling, maxFOD is 0.002 and 0.0 for cranial and extra-cranial cases, respectively. The intFOD for the wall at the patient’s feet, is 0.094 for cranial and 0.005 for extra-cranial cases. There is nearly no difference between the maxFOD of the right and left wall for cranial cases, whereas for extra-cranial cases these numbers differ by a factor of 1.75. Conclusion: The varying FODs for the Cyberknife were quantified based on delivered treatment plans. These findings are helpful regarding the design of Cyberknife vaults.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, K; John R Marsh Cancer Center
Purpose: To evaluate the clinical rationale for Truebeam and Trilogy Linac machines from Varian Medical System as exchangeable treatment modalities in the same radiation oncology department. Methods: Intensity Modulated Radiotherapy (IMRT) plans for different diseases were selected for this study. These disease sites included brain, head and neck, breast, lung, and prostate. The parameters selected for this study were the energy amount, Monitor Unit (MU); dose coverage of target reflected by prescription isodose volume(PIV); dose spillage described by the volume of 50% isodoseline of the prescription; and dose homogeneities represented by the maximum dose (MaxD) and the minimum dose (MinD)more » of target volume (TV) and critical structure (CS). Each percentage difference between the values of these parameters formed an element of a matrix, which was called Similarity Comparison Matrix(SCM). The elements of the SCM were then simplified by dimensional conversion algorithm, which was used to determine clinical similarity between two machines through a single value. Results: For the selected clinical cases in this study, the average percentage differences between Trilogy and Truebeam in MU was 0.28% with standard deviation(SD) 0.66%, PIV was 0.23% with SD 0.20%, Volume at 50% prescription dose was 0.31% with SD at 0.78%, MaxD at TV is 0.26% with SD 0.35%, MinD at TV is −0.04% with SD 0.51%, MaxD in CS is −0.53% with SD 0.92%, and MinD in CS 3.31%, with SD at 2.89%. The sum, product, geometric and harmonic mean for the matrix elements were 19.0%, 0.00%, 0.19%, and 0.00%. Conclusion: A method to compare two machines in clinical level was developed and some reference values were calculated for decision-making in clinical practice, and this strategy could be expanded to different clinical applications.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fujikawa, B.K.
We report on a recent search for {bar {nu}}{sub e} appearance from stopped {pi}{sup +} {yields} {mu}{sup +}{nu}{sub {mu}} and {mu}{sup +} {yields} e{sup +}{nu}{sub e}{bar {nu}}{sub {mu}} decay made by the LAMPF experiment E645. The appearance of {bar {nu}}{sub e} may occur from {bar {nu}}{sub {mu}} {yields} {bar {nu}}{sub e}, {nu}{sub e} {yields} {bar {nu}}{sub eL}, or {nu}{sub {mu}} {yields} {bar {nu}}{sub eL} oscillations. Appearance may also occur from rare {mu}{sup +} {yields} e{sup +}{bar {nu}}{sub e}{nu}{sub {mu}} decay, which is allowed by a multiplicative lepton charge conservation law. The neutrino energies range from E{sub {nu}} = 0 tomore » 52.8MeV. The neutrino detector, which is located 26.1 meters from the neutrino source, consists of a segmented liquid scintillator and proportional drift tube central detector surrounded by both active and passive shielding. The central detector detects {bar {nu}}{sub e} through the {bar {nu}}{sub e}p {yields} ne{sup +} Charge Current (CC) reaction, which is signaled by the direct detection of the final state positron and neutron. The hydrogen-rich liquid scintillators act as free proton targets for the {bar {nu}}{sub e}p CC reaction. The neutrons are detected through radiative neutron capture on gadolinium. We find no evidence for {bar {nu}}{sub e} appearance in the first year of running. New limits on the {bar {nu}}{sub {mu}},{nu}{sub e},{nu}{sub {mu}} {yields} {bar {nu}}{sub e} oscillation parameters and the rare {mu}{sup +} {yields} e{sup +}{bar {nu}}{sub e}{nu}{sub {mu}} decay branching ratio are presented. 87 refs., 45 figs., 17 tabs.« less
Kiguchi, Yuri; Aono, Yuri; Watanabe, Yuriko; Yamamoto-Nemoto, Seiko; Shimizu, Kunihiko; Shimizu, Takehiko; Kosuge, Yasuhiro; Waddington, John L; Ishige, Kumiko; Ito, Yoshihisa; Saigusa, Tadashi
2016-10-15
Cholinergic neurons in the nucleus accumbens express delta- and mu-opioid receptors that are thought to inhibit neural activity. Delta- and mu-opioid receptors are divided into delta1- and delta2-opioid receptors and mu1- and mu2-opioid receptors, respectively. We analysed the roles of delta- and mu-opioid receptor subtypes in regulating accumbal acetylcholine efflux of freely moving rats using in vivo microdialysis. Other than naloxonazine, given intraperitoneally, delta- and mu-opioid receptor ligands were administered intracerebrally through the dialysis probe. Doses of these compounds indicate total amount (mol) over an infusion time of 30-60min. To monitor basal acetylcholine, a low concentration of physostigmine (50nM) was added to the perfusate. The delta1-opioid receptor agonist DPDPE (3 and 300pmol) and delta2-opioid receptor agonist deltorphin II (3 and 30pmol) decreased accumbal acetylcholine in a dose-related manner. DPDPE (300pmol)- and deltorphin II (3pmol)-induced reductions in acetylcholine were each inhibited by the delta1-opioid receptor antagonist BNTX (0.3pmol) and delta2-opioid receptor antagonist naltriben (15pmol), respectively. The mu-opioid receptor agonists endomorphin-1 and endomorphin-2 (6 and 30nmol) decreased acetylcholine in a dose-related manner. Endomorphin-1- and endomorphin-2 (30nmol)-induced reductions in acetylcholine were prevented by the mu-opioid receptor antagonist CTOP (3nmol). The mu1-opioid receptor antagonist naloxonazine (15mg/kg ip), which inhibits endomorphin-1 (15nmol)-induced accumbal dopamine efflux, did not alter endomorphin-1- or endomorphin-2 (30nmol)-induced reductions in acetylcholine efflux. This study provides in vivo evidence for delta1-, delta2- and mu2-opioid receptors, but not mu1-opioid receptors, that inhibit accumbal cholinergic neural activity. Copyright © 2016 Elsevier B.V. All rights reserved.
Quantitative analysis of ground penetrating radar data in the Mu Us Sandland
NASA Astrophysics Data System (ADS)
Fu, Tianyang; Tan, Lihua; Wu, Yongqiu; Wen, Yanglei; Li, Dawei; Duan, Jinlong
2018-06-01
Ground penetrating radar (GPR), which can reveal the sedimentary structure and development process of dunes, is widely used to evaluate aeolian landforms. The interpretations for GPR profiles are mostly based on qualitative descriptions of geometric features of the radar reflections. This research quantitatively analyzed the waveform parameter characteristics of different radar units by extracting the amplitude and time interval parameters of GPR data in the Mu Us Sandland in China, and then identified and interpreted different sedimentary structures. The results showed that different types of radar units had specific waveform parameter characteristics. The main waveform parameter characteristics of sand dune radar facies and sandstone radar facies included low amplitudes and wide ranges of time intervals, ranging from 0 to 0.25 and 4 to 33 ns respectively, and the mean amplitudes changed gradually with time intervals. The amplitude distribution curves of various sand dune radar facies were similar as unimodal distributions. The radar surfaces showed high amplitudes with time intervals concentrated in high-value areas, ranging from 0.08 to 0.61 and 9 to 34 ns respectively, and the mean amplitudes changed drastically with time intervals. The amplitude and time interval values of lacustrine radar facies were between that of sand dune radar facies and radar surfaces, ranging from 0.08 to 0.29 and 11 to 30 ns respectively, and the mean amplitude and time interval curve was approximately trapezoidal. The quantitative extraction and analysis of GPR reflections could help distinguish various radar units and provide evidence for identifying sedimentary structure in aeolian landforms.
Effects of whole body vibration on motor unit recruitment and threshold
Woledge, Roger C.; Martin, Finbarr C.; Newham, Di J.
2012-01-01
Whole body vibration (WBV) has been suggested to elicit reflex muscle contractions but this has never been verified. We recorded from 32 single motor units (MU) in the vastus lateralis of 7 healthy subjects (34 ± 15.4 yr) during five 1-min bouts of WBV (30 Hz, 3 mm peak to peak), and the vibration waveform was also recorded. Recruitment thresholds were recorded from 38 MUs before and after WBV. The phase angle distribution of all MUs during WBV was nonuniform (P < 0.001) and displayed a prominent peak phase angle of firing. There was a strong linear relationship (r = −0.68, P < 0.001) between the change in recruitment threshold after WBV and average recruitment threshold; the lowest threshold MUs increased recruitment threshold (P = 0.008) while reductions were observed in the higher threshold units (P = 0.031). We investigated one possible cause of changed thresholds. Presynaptic inhibition in the soleus was measured in 8 healthy subjects (29 ± 4.6 yr). A total of 30 H-reflexes (stimulation intensity 30% Mmax) were recorded before and after WBV: 15 conditioned by prior stimulation (60 ms) of the antagonist and 15 unconditioned. There were no significant changes in the relationship between the conditioned and unconditioned responses. The consistent phase angle at which each MU fired during WBV indicates the presence of reflex muscle activity similar to the tonic vibration reflex. The varying response in high- and low-threshold MUs may be due to the different contributions of the mono- and polysynaptic pathways but not presynaptic inhibition. PMID:22096119
Effects of whole body vibration on motor unit recruitment and threshold.
Pollock, Ross D; Woledge, Roger C; Martin, Finbarr C; Newham, Di J
2012-02-01
Whole body vibration (WBV) has been suggested to elicit reflex muscle contractions but this has never been verified. We recorded from 32 single motor units (MU) in the vastus lateralis of 7 healthy subjects (34 ± 15.4 yr) during five 1-min bouts of WBV (30 Hz, 3 mm peak to peak), and the vibration waveform was also recorded. Recruitment thresholds were recorded from 38 MUs before and after WBV. The phase angle distribution of all MUs during WBV was nonuniform (P < 0.001) and displayed a prominent peak phase angle of firing. There was a strong linear relationship (r = -0.68, P < 0.001) between the change in recruitment threshold after WBV and average recruitment threshold; the lowest threshold MUs increased recruitment threshold (P = 0.008) while reductions were observed in the higher threshold units (P = 0.031). We investigated one possible cause of changed thresholds. Presynaptic inhibition in the soleus was measured in 8 healthy subjects (29 ± 4.6 yr). A total of 30 H-reflexes (stimulation intensity 30% Mmax) were recorded before and after WBV: 15 conditioned by prior stimulation (60 ms) of the antagonist and 15 unconditioned. There were no significant changes in the relationship between the conditioned and unconditioned responses. The consistent phase angle at which each MU fired during WBV indicates the presence of reflex muscle activity similar to the tonic vibration reflex. The varying response in high- and low-threshold MUs may be due to the different contributions of the mono- and polysynaptic pathways but not presynaptic inhibition.