40 CFR 63.1275 - Glycol dehydration unit process vent standards.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 12 2014-07-01 2014-07-01 false Glycol dehydration unit process vent... Storage Facilities § 63.1275 Glycol dehydration unit process vent standards. (a) This section applies to each glycol dehydration unit subject to this subpart that must be controlled for air emissions as...
40 CFR 63.1275 - Glycol dehydration unit process vent standards.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 12 2013-07-01 2013-07-01 false Glycol dehydration unit process vent... Storage Facilities § 63.1275 Glycol dehydration unit process vent standards. (a) This section applies to each glycol dehydration unit subject to this subpart that must be controlled for air emissions as...
40 CFR 63.1275 - Glycol dehydration unit process vent standards.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 12 2012-07-01 2011-07-01 true Glycol dehydration unit process vent... Facilities § 63.1275 Glycol dehydration unit process vent standards. (a) This section applies to each glycol dehydration unit subject to this subpart with an actual annual average natural gas flowrate equal to or...
40 CFR 63.1275 - Glycol dehydration unit process vent standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 11 2010-07-01 2010-07-01 true Glycol dehydration unit process vent... Facilities § 63.1275 Glycol dehydration unit process vent standards. (a) This section applies to each glycol dehydration unit subject to this subpart with an actual annual average natural gas flowrate equal to or...
40 CFR 63.765 - Glycol dehydration unit process vent standards.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 11 2013-07-01 2013-07-01 false Glycol dehydration unit process vent... Facilities § 63.765 Glycol dehydration unit process vent standards. (a) This section applies to each glycol dehydration unit subject to this subpart that must be controlled for air emissions as specified in either...
40 CFR 63.765 - Glycol dehydration unit process vent standards.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 10 2011-07-01 2011-07-01 false Glycol dehydration unit process vent... Facilities § 63.765 Glycol dehydration unit process vent standards. (a) This section applies to each glycol dehydration unit subject to this subpart with an actual annual average natural gas flowrate equal to or...
40 CFR 63.765 - Glycol dehydration unit process vent standards.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Glycol dehydration unit process vent... Facilities § 63.765 Glycol dehydration unit process vent standards. (a) This section applies to each glycol dehydration unit subject to this subpart that must be controlled for air emissions as specified in either...
40 CFR 63.765 - Glycol dehydration unit process vent standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Glycol dehydration unit process vent... Facilities § 63.765 Glycol dehydration unit process vent standards. (a) This section applies to each glycol dehydration unit subject to this subpart with an actual annual average natural gas flowrate equal to or...
40 CFR 63.1275 - Glycol dehydration unit process vent standards.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 11 2011-07-01 2011-07-01 false Glycol dehydration unit process vent... Facilities § 63.1275 Glycol dehydration unit process vent standards. (a) This section applies to each glycol dehydration unit subject to this subpart with an actual annual average natural gas flowrate equal to or...
40 CFR 63.765 - Glycol dehydration unit process vent standards.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 11 2012-07-01 2012-07-01 false Glycol dehydration unit process vent... Facilities § 63.765 Glycol dehydration unit process vent standards. (a) This section applies to each glycol dehydration unit subject to this subpart with an actual annual average natural gas flowrate equal to or...
40 CFR 63.764 - General standards.
Code of Federal Regulations, 2011 CFR
2011-07-01
... in paragraphs (c)(1) through (3) of this section. (1) For each glycol dehydration unit process vent... requirements for glycol dehydration unit process vents specified in § 63.765; (ii) The owner or operator shall... requirements for glycol dehydration unit process vents specified in § 63.765; (ii) The monitoring requirements...
40 CFR 63.764 - General standards.
Code of Federal Regulations, 2014 CFR
2014-07-01
... in paragraphs (c)(1) through (3) of this section. (1) For each glycol dehydration unit process vent... requirements for glycol dehydration unit process vents specified in § 63.765; (ii) The owner or operator shall... requirements for glycol dehydration unit process vents specified in § 63.765; (ii) The monitoring requirements...
40 CFR 63.764 - General standards.
Code of Federal Regulations, 2013 CFR
2013-07-01
... in paragraphs (c)(1) through (3) of this section. (1) For each glycol dehydration unit process vent... requirements for glycol dehydration unit process vents specified in § 63.765; (ii) The owner or operator shall... requirements for glycol dehydration unit process vents specified in § 63.765; (ii) The monitoring requirements...
40 CFR 63.764 - General standards.
Code of Federal Regulations, 2012 CFR
2012-07-01
... in paragraphs (c)(1) through (3) of this section. (1) For each glycol dehydration unit process vent... requirements for glycol dehydration unit process vents specified in § 63.765; (ii) The owner or operator shall... requirements for glycol dehydration unit process vents specified in § 63.765; (ii) The monitoring requirements...
40 CFR 63.764 - General standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... in paragraphs (c)(1) through (3) of this section. (1) For each glycol dehydration unit process vent... requirements for glycol dehydration unit process vents specified in § 63.765; (ii) The owner or operator shall... requirements for glycol dehydration unit process vents specified in § 63.765; (ii) The monitoring requirements...
40 CFR 63.1016 - Alternative means of emission limitation: Enclosed-vented process units.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Alternative means of emission limitation: Enclosed-vented process units. 63.1016 Section 63.1016 Protection of Environment ENVIRONMENTAL... § 63.1016 Alternative means of emission limitation: Enclosed-vented process units. (a) Use of closed...
40 CFR 63.1016 - Alternative means of emission limitation: Enclosed-vented process units.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 10 2011-07-01 2011-07-01 false Alternative means of emission limitation: Enclosed-vented process units. 63.1016 Section 63.1016 Protection of Environment ENVIRONMENTAL... § 63.1016 Alternative means of emission limitation: Enclosed-vented process units. (a) Use of closed...
Code of Federal Regulations, 2014 CFR
2014-07-01
... permit limit applicable to the process vent. (iv) Design analysis based on accepted chemical engineering... rates, halogenated process vent determinations, process vent TRE index values, and engineering... corrected to 2.3 percent moisture; or (2) The engineering assessment procedures in paragraph (k) of this...
Code of Federal Regulations, 2013 CFR
2013-07-01
... permit limit applicable to the process vent. (iv) Design analysis based on accepted chemical engineering... rates, halogenated process vent determinations, process vent TRE index values, and engineering... corrected to 2.3 percent moisture; or (2) The engineering assessment procedures in paragraph (k) of this...
Code of Federal Regulations, 2011 CFR
2011-07-01
... permit limit applicable to the process vent. (iv) Design analysis based on accepted chemical engineering... rates, halogenated process vent determinations, process vent TRE index values, and engineering... corrected to 2.3 percent moisture; or (2) The engineering assessment procedures in paragraph (k) of this...
Code of Federal Regulations, 2012 CFR
2012-07-01
... permit limit applicable to the process vent. (iv) Design analysis based on accepted chemical engineering... rates, halogenated process vent determinations, process vent TRE index values, and engineering... corrected to 2.3 percent moisture; or (2) The engineering assessment procedures in paragraph (k) of this...
40 CFR 63.107 - Identification of process vents subject to this subpart.
Code of Federal Regulations, 2011 CFR
2011-07-01
... CATEGORIES National Emission Standards for Organic Hazardous Air Pollutants From the Synthetic Organic Chemical Manufacturing Industry § 63.107 Identification of process vents subject to this subpart. (a) The..., distillation unit, or reactor during operation of the chemical manufacturing process unit. (c) The discharge to...
40 CFR 63.107 - Identification of process vents subject to this subpart.
Code of Federal Regulations, 2013 CFR
2013-07-01
... CATEGORIES National Emission Standards for Organic Hazardous Air Pollutants From the Synthetic Organic Chemical Manufacturing Industry § 63.107 Identification of process vents subject to this subpart. (a) The..., distillation unit, or reactor during operation of the chemical manufacturing process unit. (c) The discharge to...
40 CFR 63.107 - Identification of process vents subject to this subpart.
Code of Federal Regulations, 2014 CFR
2014-07-01
... CATEGORIES National Emission Standards for Organic Hazardous Air Pollutants From the Synthetic Organic Chemical Manufacturing Industry § 63.107 Identification of process vents subject to this subpart. (a) The..., distillation unit, or reactor during operation of the chemical manufacturing process unit. (c) The discharge to...
40 CFR 63.640 - Applicability and designation of affected source.
Code of Federal Regulations, 2014 CFR
2014-07-01
... reformer catalyst regeneration vents, and sulfur plant vents; and (5) Emission points routed to a fuel gas... required for refinery fuel gas systems or emission points routed to refinery fuel gas systems. (e) The... petroleum refining process unit that is subject to this subpart; (3) Units processing natural gas liquids...
40 CFR 63.640 - Applicability and designation of affected source.
Code of Federal Regulations, 2013 CFR
2013-07-01
... reformer catalyst regeneration vents, and sulfur plant vents; and (5) Emission points routed to a fuel gas... required for refinery fuel gas systems or emission points routed to refinery fuel gas systems. (e) The... petroleum refining process unit that is subject to this subpart; (3) Units processing natural gas liquids...
40 CFR 63.2450 - What are my general requirements for complying with this subpart?
Code of Federal Regulations, 2011 CFR
2011-07-01
... values are available for at least two of the 15-minute periods during an hour when calibration, quality... during periods of startup, shutdown, and malfunction (SSM), and you must meet the requirements specified...., continuous process vents, batch process vents, storage tanks, transfer operations, and waste management units...
40 CFR 63.2450 - What are my general requirements for complying with this subpart?
Code of Federal Regulations, 2013 CFR
2013-07-01
... values are available for at least two of the 15-minute periods during an hour when calibration, quality..., except during periods of startup, shutdown, and malfunction (SSM), and you must meet the requirements...., continuous process vents, batch process vents, storage tanks, transfer operations, and waste management units...
40 CFR 65.149 - Boilers and process heaters.
Code of Federal Regulations, 2010 CFR
2010-07-01
... stream is not introduced as or with the primary fuel, a temperature monitoring device in the fire box...-throughput transfer racks, as applicable, shall meet the requirements of this section. (2) The vent stream... thermal units per hour) or greater. (ii) A boiler or process heater into which the vent stream is...
40 CFR 63.107 - Identification of process vents subject to this subpart.
Code of Federal Regulations, 2010 CFR
2010-07-01
... to this subpart. 63.107 Section 63.107 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... going to a fuel gas system as defined in § 63.101. (4) A gas stream exiting a control device used to... transfer operation vent subject to § 63.119 or § 63.126. (8) A vent from a waste management unit subject to...
40 CFR 63.107 - Identification of process vents subject to this subpart.
Code of Federal Regulations, 2012 CFR
2012-07-01
... process vents associated with an air oxidation reactor, distillation unit, or reactor that is in a source.... (b) Some, or all, of the gas stream originates as a continuous flow from an air oxidation reactor... specified in paragraphs (c)(1) through (3) of this section. (1) Is directly from an air oxidation reactor...
40 CFR 65.118 - Alternative means of emission limitation: Enclosed-vented process units.
Code of Federal Regulations, 2010 CFR
2010-07-01
... PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Equipment Leaks § 65.118... control device. Process units that are enclosed in such a manner that all emissions from equipment leaks...
40 CFR 63.1281 - Control equipment requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... dehydration unit baseline operations (as defined in § 63.1271). Records of glycol dehydration unit baseline... the Administrator's satisfaction, the conditions for which glycol dehydration unit baseline operations... emission reduction of 95.0 percent for the glycol dehydration unit process vent. Only modifications in...
40 CFR 63.1281 - Control equipment requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... dehydration unit baseline operations (as defined in § 63.1271). Records of glycol dehydration unit baseline... the Administrator's satisfaction, the conditions for which glycol dehydration unit baseline operations... emission reduction of 95.0 percent for the glycol dehydration unit process vent. Only modifications in...
Code of Federal Regulations, 2010 CFR
2010-07-01
... recovery device or series of such devices applied to the same process stream. Total organic compounds (TOC...(d)(5) and § 60.614(e) and TOC concentration as required in § 60.615(b)(4) and § 60.615(g)(4), those... requirement per unit reduction of TOC associated with an individual air oxidation vent stream, based on vent...
40 CFR 63.1274 - General standards.
Code of Federal Regulations, 2013 CFR
2013-07-01
... of an affected source (i.e., glycol dehydration unit) located at an existing or new major source of... requirements for glycol dehydration unit process vents specified in § 63.1275; (2) The monitoring requirements...
40 CFR 63.1274 - General standards.
Code of Federal Regulations, 2014 CFR
2014-07-01
... of an affected source (i.e., glycol dehydration unit) located at an existing or new major source of... requirements for glycol dehydration unit process vents specified in § 63.1275; (2) The monitoring requirements...
Code of Federal Regulations, 2010 CFR
2010-07-01
... streams in open systems within a chemical manufacturing process unit. 63.149 Section 63.149 Protection of... open systems within a chemical manufacturing process unit. (a) The owner or operator shall comply with... Air Pollutants From the Synthetic Organic Chemical Manufacturing Industry for Process Vents, Storage...
Improved thermodynamic modeling of the no-vent fill process and correlation with experimental data
NASA Technical Reports Server (NTRS)
Taylor, William J.; Chato, David J.
1991-01-01
The United States' plans to establish a permanent manned presence in space and to explore the Solar System created the need to efficiently handle large quantities of subcritical cryogenic fluids, particularly propellants such as liquid hydrogen and liquid oxygen, in low- to zero-gravity environments. One of the key technologies to be developed for fluid handling is the ability to transfer the cryogens between storage and spacecraft tanks. The no-vent fill method was identified as one way to perform this transfer. In order to understand how to apply this method, a model of the no-vent fill process is being developed and correlated with experimental data. The verified models then can be used to design and analyze configurations for tankage and subcritical fluid depots. The development of an improved macroscopic thermodynamic model is discussed of the no-vent fill process and the analytical results from the computer program implementation of the model are correlated with experimental results for two different test tanks.
40 CFR 63.775 - Reporting requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... operator of a glycol dehydration unit subject to this subpart that is exempt from the control requirements for glycol dehydration unit process vents in § 63.765, is exempt from all reporting requirements for....0 or higher and documentation stating why the TEG dehydration unit must operate using the alternate...
Code of Federal Regulations, 2013 CFR
2013-07-01
... that returns process fluid to the process and is not vented directly to the atmosphere. Closed-purge.... Combustion device means an individual unit of equipment, such as a flare, incinerator, process heater, or..., flares, boilers, and process heaters. Primary condensers on steam strippers or fuel gas systems are not...
Code of Federal Regulations, 2014 CFR
2014-07-01
... that returns process fluid to the process and is not vented directly to the atmosphere. Closed-purge.... Combustion device means an individual unit of equipment, such as a flare, incinerator, process heater, or..., flares, boilers, and process heaters. Primary condensers on steam strippers or fuel gas systems are not...
Code of Federal Regulations, 2011 CFR
2011-07-01
... that returns process fluid to the process and is not vented directly to the atmosphere. Closed-purge.... Combustion device means an individual unit of equipment, such as a flare, incinerator, process heater, or..., flares, boilers, and process heaters. Primary condensers on steam strippers or fuel gas systems are not...
Code of Federal Regulations, 2012 CFR
2012-07-01
... that returns process fluid to the process and is not vented directly to the atmosphere. Closed-purge.... Combustion device means an individual unit of equipment, such as a flare, incinerator, process heater, or..., flares, boilers, and process heaters. Primary condensers on steam strippers or fuel gas systems are not...
40 CFR 270.24 - Specific part B information requirements for process vents.
Code of Federal Regulations, 2010 CFR
2010-07-01
...., identify the hazardous waste management units on a facility plot plan). (2) Information and data supporting... concentrations) that represent the conditions that exist when the waste management unit is operating at the... when the hazardous waste management unit is or would be operating at the highest load or capacity level...
40 CFR 65.62 - Process vent group determination.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., or Group 2B) for each process vent. Group 1 process vents require control, and Group 2A and 2B... 40 Protection of Environment 15 2010-07-01 2010-07-01 false Process vent group determination. 65... (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Process Vents § 65.62 Process vent group determination. (a) Group...
40 CFR 63.1562 - What parts of my plant are covered by this subpart?
Code of Federal Regulations, 2012 CFR
2012-07-01
... regeneration of the catalyst used in the unit (i.e., the catalyst regeneration flue gas vent). (2) The process...-regenerative, cyclic, or continuous processes) that are associated with regeneration of the catalyst used in...
40 CFR 63.1562 - What parts of my plant are covered by this subpart?
Code of Federal Regulations, 2013 CFR
2013-07-01
... regeneration of the catalyst used in the unit (i.e., the catalyst regeneration flue gas vent). (2) The process...-regenerative, cyclic, or continuous processes) that are associated with regeneration of the catalyst used in...
40 CFR 63.1562 - What parts of my plant are covered by this subpart?
Code of Federal Regulations, 2011 CFR
2011-07-01
... regeneration of the catalyst used in the unit (i.e., the catalyst regeneration flue gas vent). (2) The process...-regenerative, cyclic, or continuous processes) that are associated with regeneration of the catalyst used in...
40 CFR 63.1562 - What parts of my plant are covered by this subpart?
Code of Federal Regulations, 2014 CFR
2014-07-01
... regeneration of the catalyst used in the unit (i.e., the catalyst regeneration flue gas vent). (2) The process...-regenerative, cyclic, or continuous processes) that are associated with regeneration of the catalyst used in...
40 CFR 63.1562 - What parts of my plant are covered by this subpart?
Code of Federal Regulations, 2010 CFR
2010-07-01
... regeneration of the catalyst used in the unit (i.e., the catalyst regeneration flue gas vent). (2) The process...-regenerative, cyclic, or continuous processes) that are associated with regeneration of the catalyst used in...
Jiang, Guobin; Liu, Dan; Chen, Weiming; Ye, Zhicheng; Liu, Hong; Li, Qibin
2017-10-01
The evolution mechanism of a vent pipe diameter on a waste-stabilization process in semi-aerobic bioreactor landfills was analyzed from the organic-matter concentration, biodegradability, spectral characteristics of dissolved organic matter, correlations and principal-component analysis. Waste samples were collected at different distances from the vent pipe and from different landfill layers in semi-aerobic bioreactor landfills with different vent pipe diameters. An increase in vent pipe diameter favored waste degradation. Waste degradation in landfills can be promoted slightly when the vent pipe diameter increases from 25 to 50 mm. It could be promoted significantly when the vent pipe diameter was increased to 75 mm. The vent pipe diameter is important in waste degradation in the middle layer of landfills. The dissolved organic matter in the waste is composed mainly of long-wave humus (humin), short-wave humus (fulvic acid) and tryptophan. The humification levels of the waste that was located at the center of vent pipes with 25-, 50- and 75-mm diameters were 2.2682, 4.0520 and 7.6419 Raman units, respectively. The appropriate vent pipe diameter for semi-aerobic bioreactor landfills with an 800-mm diameter was 75 mm. The effect of different vent pipe diameters on the degree of waste stabilization is reflected by two main components. Component 1 is related mainly to the content of fulvic acid, biologically degradable material and organic matter. Component 2 is related mainly to the content of tryptophan and humin from the higher vascular plants.
40 CFR 63.12005 - What definitions apply to this subpart?
Code of Federal Regulations, 2012 CFR
2012-07-01
... venting episode that is associated with a single unit operation. A unit operation may have more than one... characterized by a two-step anhydrous polymerization process: the formation of small resin particles in a pre... of the resin particles in a post-polymerization reactor using additional vinyl chloride monomer...
40 CFR 63.1274 - General standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) of this section, the owner or operator of an affected source (i.e., glycol dehydration unit) located... subpart as follows: (1) The control requirements for glycol dehydration unit process vents specified in... maintained as required in § 63.1284(d). (1) The actual annual average flow of gas to the glycol dehydration...
40 CFR 63.1274 - General standards.
Code of Federal Regulations, 2012 CFR
2012-07-01
...) of this section, the owner or operator of an affected source (i.e., glycol dehydration unit) located... subpart as follows: (1) The control requirements for glycol dehydration unit process vents specified in... maintained as required in § 63.1284(d). (1) The actual annual average flow of gas to the glycol dehydration...
40 CFR 63.1274 - General standards.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) of this section, the owner or operator of an affected source (i.e., glycol dehydration unit) located... subpart as follows: (1) The control requirements for glycol dehydration unit process vents specified in... maintained as required in § 63.1284(d). (1) The actual annual average flow of gas to the glycol dehydration...
40 CFR 65.62 - Process vent group determination.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 16 2012-07-01 2012-07-01 false Process vent group determination. 65... (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Process Vents § 65.62 Process vent group determination. (a) Group status. The owner or operator of a process vent shall determine the group status (i.e., Group 1, Group 2A...
40 CFR 65.62 - Process vent group determination.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 16 2014-07-01 2014-07-01 false Process vent group determination. 65... (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Process Vents § 65.62 Process vent group determination. (a) Group status. The owner or operator of a process vent shall determine the group status (i.e., Group 1, Group 2A...
40 CFR 65.62 - Process vent group determination.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 15 2011-07-01 2011-07-01 false Process vent group determination. 65... (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Process Vents § 65.62 Process vent group determination. (a) Group status. The owner or operator of a process vent shall determine the group status (i.e., Group 1, Group 2A...
A classification scheme for the morphology of lava flow fields
NASA Technical Reports Server (NTRS)
Wilson, L.; Pinkerton, H.; Head, James W.; Roberts, K. Magee
1993-01-01
Analysis of the processes controlling the advance of lava flows shows that, if no other factors intervene, thermal constraints will act to limit the maximum length of a flow being fed at a given volume or mass effusion rate from a vent. These constraints can be characterized through the Gratz number, which takes on a large value at the vent and decreases down flow. Early application of this principle showed that, despite the many subtleties of modes of heat loss from flows, motion apparently ceases when the Gratz number has decreased to a value close to 300. Recent analyses of flow units from the 1983-86 Pu'u 'O'o eruption of Kilauea and of other, more silicic lava flow units confirm this finding.
40 CFR 63.1406 - Reactor batch process vent provisions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 11 2011-07-01 2011-07-01 false Reactor batch process vent provisions... § 63.1406 Reactor batch process vent provisions. (a) Emission standards. Owners or operators of reactor... reactor batch process vent located at a new affected source shall control organic HAP emissions by...
40 CFR 63.1406 - Reactor batch process vent provisions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 11 2010-07-01 2010-07-01 true Reactor batch process vent provisions... § 63.1406 Reactor batch process vent provisions. (a) Emission standards. Owners or operators of reactor... reactor batch process vent located at a new affected source shall control organic HAP emissions by...
40 CFR 63.115 - Process vent provisions-methods and procedures for process vent group determination.
Code of Federal Regulations, 2011 CFR
2011-07-01
... accepted chemical engineering principles, measurable process parameters, or physical or chemical laws or... From the Synthetic Organic Chemical Manufacturing Industry for Process Vents, Storage Vessels, Transfer... (d)(3) of this section. (1) Engineering assessment may be used to determine vent stream flow rate...
40 CFR 63.115 - Process vent provisions-methods and procedures for process vent group determination.
Code of Federal Regulations, 2013 CFR
2013-07-01
... accepted chemical engineering principles, measurable process parameters, or physical or chemical laws or... From the Synthetic Organic Chemical Manufacturing Industry for Process Vents, Storage Vessels, Transfer... (d)(3) of this section. (1) Engineering assessment may be used to determine vent stream flow rate...
40 CFR 63.115 - Process vent provisions-methods and procedures for process vent group determination.
Code of Federal Regulations, 2014 CFR
2014-07-01
... accepted chemical engineering principles, measurable process parameters, or physical or chemical laws or... From the Synthetic Organic Chemical Manufacturing Industry for Process Vents, Storage Vessels, Transfer... (d)(3) of this section. (1) Engineering assessment may be used to determine vent stream flow rate...
40 CFR 63.115 - Process vent provisions-methods and procedures for process vent group determination.
Code of Federal Regulations, 2012 CFR
2012-07-01
... accepted chemical engineering principles, measurable process parameters, or physical or chemical laws or... From the Synthetic Organic Chemical Manufacturing Industry for Process Vents, Storage Vessels, Transfer... (d)(3) of this section. (1) Engineering assessment may be used to determine vent stream flow rate...
Code of Federal Regulations, 2010 CFR
2010-07-01
... drain system, a gravity-operated conveyor (such as a chute), and a mechanically-powered conveyor (such... features permanently integrated into the design of the unit. Emission point means an individual tank, surface impoundment, container, oil-water or organic-water separator, transfer system, process vent, or...
Code of Federal Regulations, 2013 CFR
2013-07-01
... regeneration stream mass or volumetric flow during carbon bed regeneration cycle; and temperature of the carbon bed after regeneration (and within 15 minutes of completing any cooling cycle(s)) Maximum mass or...
Code of Federal Regulations, 2012 CFR
2012-07-01
... drain system, a gravity-operated conveyor (such as a chute), and a mechanically-powered conveyor (such... features permanently integrated into the design of the unit. Emission point means an individual tank, surface impoundment, container, oil-water or organic-water separator, transfer system, process vent, or...
Code of Federal Regulations, 2014 CFR
2014-07-01
... drain system, a gravity-operated conveyor (such as a chute), and a mechanically-powered conveyor (such... features permanently integrated into the design of the unit. Emission point means an individual tank, surface impoundment, container, oil-water or organic-water separator, transfer system, process vent, or...
40 CFR 63.1407 - Non-reactor batch process vent provisions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 11 2010-07-01 2010-07-01 true Non-reactor batch process vent... § 63.1407 Non-reactor batch process vent provisions. (a) Emission standards. (1) Owners or operators of non-reactor batch process vents located at new or existing affected sources with 0.25 tons per year (0...
40 CFR 63.1407 - Non-reactor batch process vent provisions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 11 2011-07-01 2011-07-01 false Non-reactor batch process vent... § 63.1407 Non-reactor batch process vent provisions. (a) Emission standards. (1) Owners or operators of non-reactor batch process vents located at new or existing affected sources with 0.25 tons per year (0...
40 CFR 63.1430 - Process vent reporting and recordkeeping requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... is subject to the Group 1 batch process vent control requirements for nonepoxide HAP emissions from...) Records to demonstrate compliance. The owner or operator complying with the process vent control...: (1) When using a flare to comply with the process vent control requirements in § 63.1425(b)(2)(i), (c...
Code of Federal Regulations, 2011 CFR
2011-07-01
... operating as a reflux condenser on a reactor or distillation column shall be considered part of the unit... operation. For the purpose of these determinations, the primary condenser operating as a reflux condenser on...
Code of Federal Regulations, 2014 CFR
2014-07-01
... operating as a reflux condenser on a reactor or distillation column shall be considered part of the unit... operation. For the purpose of these determinations, the primary condenser operating as a reflux condenser on...
Code of Federal Regulations, 2013 CFR
2013-07-01
... operating as a reflux condenser on a reactor or distillation column shall be considered part of the unit... operation. For the purpose of these determinations, the primary condenser operating as a reflux condenser on...
Code of Federal Regulations, 2012 CFR
2012-07-01
... operating as a reflux condenser on a reactor or distillation column shall be considered part of the unit... operation. For the purpose of these determinations, the primary condenser operating as a reflux condenser on...
Code of Federal Regulations, 2011 CFR
2011-07-01
... process vents that emit hydrogen halide and halogen HAP or HAP metals? 63.2465 Section 63.2465 Protection... Compliance Requirements § 63.2465 What requirements must I meet for process vents that emit hydrogen halide... section. (b) If any process vents within a process emit hydrogen halide and halogen HAP, you must...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Requirements for Metal HAP Process Vents 4 Table 4 to Subpart VVVVVV of Part 63 Protection of Environment... of Part 63—Emission Limits and Compliance Requirements for Metal HAP Process Vents As required in § 63.11496(f), you must comply with the requirements for metal HAP process vents as shown in the...
40 CFR 63.491 - Batch front-end process vents-recordkeeping requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (b)(2): (i) For an incinerator or non-combustion control device, the percent reduction of organic HAP... the process vent stream is introduced with combustion air or is used as a secondary fuel and is not... combustion device to control halogenated batch front-end process vents or halogenated aggregate batch vent...
Code of Federal Regulations, 2010 CFR
2010-07-01
... uncontrolled emissions of total organic compounds (TOC) or nonmethane TOC from your process vent by 98 percent... of TOC or nonmethane TOC; or maintaining a TOC or nonmethane TOC concentration of not more than 20...
Code of Federal Regulations, 2011 CFR
2011-07-01
... hatches, sampling ports, and gauge wells provided that each opening is closed when not in use. Examples of... uncontrolled organic HAP emissions from the sum of all process vents are greater than or equal to 0.15 Mg/yr... vents are greater than or equal to 6.8 Mg/yr. Group 2 process vent means any process vent that does not...
Code of Federal Regulations, 2010 CFR
2010-07-01
... hatches, sampling ports, and gauge wells provided that each opening is closed when not in use. Examples of... uncontrolled organic HAP emissions from the sum of all process vents are greater than or equal to 0.15 Mg/yr... vents are greater than or equal to 6.8 Mg/yr. Group 2 process vent means any process vent that does not...
40 CFR 98.173 - Calculating GHG emissions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... associated requirements for Tier 4 in subpart C of this part (General Stationary Fuel Combustion Sources). (b... basis (% CO2). Q = Hourly stack gas volumetric flow rate (scfh). %H2O = Hourly moisture percentage in... vented through the same stack as any combustion unit or process equipment that reports CO2 emissions...
40 CFR 98.173 - Calculating GHG emissions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... associated requirements for Tier 4 in subpart C of this part (General Stationary Fuel Combustion Sources). (b..., dry basis (% CO2). Q = Hourly stack gas volumetric flow rate (scfh). %H2O = Hourly moisture percentage... reduction furnace are vented through the same stack as any combustion unit or process equipment that reports...
40 CFR 98.173 - Calculating GHG emissions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... associated requirements for Tier 4 in subpart C of this part (General Stationary Fuel Combustion Sources). (b... basis (% CO2). Q = Hourly stack gas volumetric flow rate (scfh). %H2O = Hourly moisture percentage in... vented through the same stack as any combustion unit or process equipment that reports CO2 emissions...
Code of Federal Regulations, 2010 CFR
2010-07-01
... provided by the primary fuel. Total organic compounds or TOC means those compounds measured according to...), and TOC concentration as required in § 60.705(b)(4) and § 60.705(f)(4), those compounds which the... per unit reduction of TOC associated with a vent stream from an affected reactor process facility...
Code of Federal Regulations, 2010 CFR
2010-07-01
... accordance with the applicable weight-percent, TOC concentration, or organic HAP concentration requirement in... rate, regulated organic HAP concentration, total organic HAP or TOC concentration, heating value, and... volumetric flow rate, regulated organic HAP concentration, total organic HAP or TOC concentration, and any...
49 CFR 179.300-13 - Venting, loading and unloading valves.
Code of Federal Regulations, 2012 CFR
2012-10-01
... HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) SPECIFICATIONS FOR TANK CARS Specifications for Multi-Unit Tank Car Tanks (Classes DOT-106A and 110AW) § 179.300-13 Venting... (h)(3)(ii). Threads for the clean-out/inspection ports of DOT Specification 110A multi-unit tank car...
Code of Federal Regulations, 2010 CFR
2010-07-01
...: Miscellaneous Organic Chemical Manufacturing Pt. 63, Subpt. FFFF, Table 2 Table 2 to Subpart FFFF of Part 63... vents a. Reduce collective uncontrolled organic HAP emissions from the sum of all batch process vents... applicable. b. Reduce collective uncontrolled organic HAP emissions from the sum of all batch process vents...
Code of Federal Regulations, 2011 CFR
2011-07-01
...: Miscellaneous Organic Chemical Manufacturing Pt. 63, Subpt. FFFF, Table 2 Table 2 to Subpart FFFF of Part 63... vents a. Reduce collective uncontrolled organic HAP emissions from the sum of all batch process vents... applicable. b. Reduce collective uncontrolled organic HAP emissions from the sum of all batch process vents...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-22
... organic compounds (TOC) (minus methane and ethane) by 98 weight-percent or to a TOC (minus methane and...- effectiveness) per unit reduction of TOC associated with an individual vent stream, based on vent stream flow rate, emission rate of TOC, net heating value and corrosion properties, whether or not the vent stream...
40 CFR 63.1322 - Batch process vents-reference control technology.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 12 2013-07-01 2013-07-01 false Batch process vents-reference control... (CONTINUED) National Emission Standards for Hazardous Air Pollutant Emissions: Group IV Polymers and Resins § 63.1322 Batch process vents—reference control technology. (a) Batch process vents. The owner or...
40 CFR 63.1322 - Batch process vents-reference control technology.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 12 2012-07-01 2011-07-01 true Batch process vents-reference control technology. 63.1322 Section 63.1322 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Batch process vents—reference control technology. (a) Batch process vents. The owner or operator of a...
40 CFR 63.1322 - Batch process vents-reference control technology.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 12 2014-07-01 2014-07-01 false Batch process vents-reference control technology. 63.1322 Section 63.1322 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... § 63.1322 Batch process vents—reference control technology. (a) Batch process vents. The owner or...
40 CFR 63.1322 - Batch process vents-reference control technology.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 11 2011-07-01 2011-07-01 false Batch process vents-reference control technology. 63.1322 Section 63.1322 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Batch process vents—reference control technology. (a) Batch process vents. The owner or operator of a...
40 CFR 63.1322 - Batch process vents-reference control technology.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 11 2010-07-01 2010-07-01 true Batch process vents-reference control technology. 63.1322 Section 63.1322 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Batch process vents—reference control technology. (a) Batch process vents. The owner or operator of a...
40 CFR 98.173 - Calculating GHG emissions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... associated requirements for Tier 4 in subpart C of this part (General Stationary Fuel Combustion Sources). (b... basis (% CO2). Q = Hourly stack gas volumetric flow rate (scfh). %H2O = Hourly moisture percentage in... furnace are vented through the same stack as any combustion unit or process equipment that reports CO2...
40 CFR 63.8240 - What are my monitoring requirements?
Code of Federal Regulations, 2012 CFR
2012-07-01
...) National Emission Standards for Hazardous Air Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali...-product hydrogen stream, each end box ventilation system vent, and each mercury thermal recovery unit vent...
40 CFR 63.487 - Batch front-end process vents-reference control technology.
Code of Federal Regulations, 2010 CFR
2010-07-01
... § 63.487 Batch front-end process vents—reference control technology. (a) Batch front-end process vents... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Batch front-end process vents-reference control technology. 63.487 Section 63.487 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...
40 CFR 63.1321 - Batch process vents provisions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Standards for Hazardous Air Pollutant Emissions: Group IV Polymers and Resins § 63.1321 Batch process vents..., owners and operators of new and existing affected sources with batch process vents shall comply with the... applicable reporting requirements in § 63.1327. (b) New SAN batch affected sources. Owners and operators of...
40 CFR 63.113 - Process vent provisions-reference control technology.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 10 2012-07-01 2012-07-01 false Process vent provisions-reference control technology. 63.113 Section 63.113 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 63.113 Process vent provisions—reference control technology. (a) The owner or operator of a Group 1...
40 CFR 63.113 - Process vent provisions-reference control technology.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 10 2013-07-01 2013-07-01 false Process vent provisions-reference control technology. 63.113 Section 63.113 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 63.113 Process vent provisions—reference control technology. (a) The owner or operator of a Group 1...
40 CFR 63.113 - Process vent provisions-reference control technology.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 9 2011-07-01 2011-07-01 false Process vent provisions-reference control technology. 63.113 Section 63.113 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 63.113 Process vent provisions—reference control technology. (a) The owner or operator of a Group 1...
40 CFR 63.113 - Process vent provisions-reference control technology.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 10 2014-07-01 2014-07-01 false Process vent provisions-reference control technology. 63.113 Section 63.113 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 63.113 Process vent provisions—reference control technology. (a) The owner or operator of a Group 1...
40 CFR 63.113 - Process vent provisions-reference control technology.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Process vent provisions-reference control technology. 63.113 Section 63.113 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 63.113 Process vent provisions—reference control technology. (a) The owner or operator of a Group 1...
40 CFR 63.7885 - What are the general standards I must meet for my affected process vents?
Code of Federal Regulations, 2011 CFR
2011-07-01
... meet for my affected process vents? 63.7885 Section 63.7885 Protection of Environment ENVIRONMENTAL... Remediation General Standards § 63.7885 What are the general standards I must meet for my affected process...) You determine for the remediation material treated or managed by the process vented through the...
40 CFR 63.7885 - What are the general standards I must meet for my affected process vents?
Code of Federal Regulations, 2013 CFR
2013-07-01
... meet for my affected process vents? 63.7885 Section 63.7885 Protection of Environment ENVIRONMENTAL... Remediation General Standards § 63.7885 What are the general standards I must meet for my affected process...) You determine for the remediation material treated or managed by the process vented through the...
40 CFR 63.7885 - What are the general standards I must meet for my affected process vents?
Code of Federal Regulations, 2014 CFR
2014-07-01
... meet for my affected process vents? 63.7885 Section 63.7885 Protection of Environment ENVIRONMENTAL... Remediation General Standards § 63.7885 What are the general standards I must meet for my affected process...) You determine for the remediation material treated or managed by the process vented through the...
40 CFR 63.7885 - What are the general standards I must meet for my affected process vents?
Code of Federal Regulations, 2012 CFR
2012-07-01
... meet for my affected process vents? 63.7885 Section 63.7885 Protection of Environment ENVIRONMENTAL... Remediation General Standards § 63.7885 What are the general standards I must meet for my affected process...) You determine for the remediation material treated or managed by the process vented through the...
Code of Federal Regulations, 2010 CFR
2010-07-01
... absorbent is used. Condenser Exit temperature Maximum temperature. Carbon adsorber Total regeneration stream mass or volumetric flow during carbon bed regeneration cycle; and temperature of the carbon bed after regeneration (and within 15 minutes of completing any cooling cycle(s)) Maximum mass or volumetric flow; and...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Carbon Adsorber f Total regeneration stream mass or volumetric flow during carbon bed regeneration cycle(s), and 1. Record of total regeneration stream mass or volumetric flow for each carbon bed regeneration cycle.2. Record and report the total regeneration stream mass or volumetric flow during each...
Code of Federal Regulations, 2012 CFR
2012-07-01
... absorbent is used. Condenser Exit temperature Maximum temperature. Carbon adsorber Total regeneration stream mass or volumetric flow during carbon bed regeneration cycle; and temperature of the carbon bed after regeneration (and within 15 minutes of completing any cooling cycle(s)) Maximum mass or volumetric flow; and...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Carbon Adsorber f Total regeneration stream mass or volumetric flow during carbon bed regeneration cycle(s), and 1. Record of total regeneration stream mass or volumetric flow for each carbon bed regeneration cycle.2. Record and report the total regeneration stream mass or volumetric flow during each...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Carbon Adsorber f Total regeneration stream mass or volumetric flow during carbon bed regeneration cycle(s), and 1. Record of total regeneration stream mass or volumetric flow for each carbon bed regeneration cycle.2. Record and report the total regeneration stream mass or volumetric flow during each...
Code of Federal Regulations, 2011 CFR
2011-07-01
... absorbent is used. Condenser Exit temperature Maximum temperature. Carbon adsorber Total regeneration stream mass or volumetric flow during carbon bed regeneration cycle; and temperature of the carbon bed after regeneration (and within 15 minutes of completing any cooling cycle(s)) Maximum mass or volumetric flow; and...
The 2010 Source Test was performed during the atmospheric depressurization step of the delayed coking process prior to the removal of petroleum coke from the coke drum. The 205 DCU was operated under a variety of conditions during the 2010 Source Test.
40 CFR 63.983 - Closed vent systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Closed vent systems. 63.983 Section 63... Emission Standards for Closed Vent Systems, Control Devices, Recovery Devices and Routing to a Fuel Gas System or a Process § 63.983 Closed vent systems. (a) Closed vent system equipment and operating...
Code of Federal Regulations, 2010 CFR
2010-07-01
...: Miscellaneous Organic Chemical Manufacturing Pt. 63, Subpt. FFFF, Table 1 Table 1 to Subpart FFFF of Part 63... vent a. Not applicable i. Reduce emissions of total organic HAP by ≥98 percent by weight or to an outlet process concentration ≤20 ppmv as organic HAP or TOC by venting emissions through a closed-vent...
Code of Federal Regulations, 2011 CFR
2011-07-01
...: Miscellaneous Organic Chemical Manufacturing Pt. 63, Subpt. FFFF, Table 1 Table 1 to Subpart FFFF of Part 63... vent a. Not applicable i. Reduce emissions of total organic HAP by ≥98 percent by weight or to an outlet process concentration ≤20 ppmv as organic HAP or TOC by venting emissions through a closed-vent...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Production § 63.1426 Process vent requirements for determining organic HAP concentration, control efficiency..., total organic HAP, or as TOC minus methane and ethane according to the procedures specified. When... methane and ethane) concentrations in all process vent streams and primary and secondary fuels introduced...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Vents, Storage Vessels, Transfer Operations, and Wastewater § 63.117 Process vent provisions—reporting... incinerators, boilers or process heaters specified in table 3 of this subpart, and averaged over the same time... content determinations, flow rate measurements, and exit velocity determinations made during the...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Vents, Storage Vessels, Transfer Operations, and Wastewater § 63.117 Process vent provisions—reporting... incinerators, boilers or process heaters specified in table 3 of this subpart, and averaged over the same time... content determinations, flow rate measurements, and exit velocity determinations made during the...
40 CFR 63.2455 - What requirements must I meet for continuous process vents?
Code of Federal Regulations, 2011 CFR
2011-07-01
... CATEGORIES National Emission Standards for Hazardous Air Pollutants: Miscellaneous Organic Chemical... any continuous process vent that is combined with Group 1 batch process vents before a control device or recovery device because the requirements of § 63.2450(c)(2)(i) apply to the combined stream. (2...
40 CFR 63.118 - Process vent provisions-periodic reporting and recordkeeping requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 9 2011-07-01 2011-07-01 false Process vent provisions-periodic..., and Wastewater § 63.118 Process vent provisions—periodic reporting and recordkeeping requirements. (a... table 3 of this subpart or specified by the Administrator in accordance with § 63.114(c) and § 63.117(e...
40 CFR 63.118 - Process vent provisions-periodic reporting and recordkeeping requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 10 2013-07-01 2013-07-01 false Process vent provisions-periodic..., and Wastewater § 63.118 Process vent provisions—periodic reporting and recordkeeping requirements. (a... table 3 of this subpart or specified by the Administrator in accordance with §§ 63.114(c) and 63.117(e...
40 CFR 63.118 - Process vent provisions-periodic reporting and recordkeeping requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 10 2012-07-01 2012-07-01 false Process vent provisions-periodic..., and Wastewater § 63.118 Process vent provisions—periodic reporting and recordkeeping requirements. (a... table 3 of this subpart or specified by the Administrator in accordance with §§ 63.114(c) and 63.117(e...
40 CFR 63.644 - Monitoring provisions for miscellaneous process vents.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) of this section, each owner or operator of a Group 1 miscellaneous process vent that uses a... detecting the presence of a pilot flame is required. (3) Any boiler or process heater with a design heat... less than 44 megawatts design heat capacity where the vent stream is not introduced into the flame zone...
40 CFR 63.644 - Monitoring provisions for miscellaneous process vents.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) of this section, each owner or operator of a Group 1 miscellaneous process vent that uses a... detecting the presence of a pilot flame is required. (3) Any boiler or process heater with a design heat... less than 44 megawatts design heat capacity where the vent stream is not introduced into the flame zone...
40 CFR 63.1413 - Compliance demonstration procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... liquids, other than fuels, received by the control device. (i) For a scrubber, the design evaluation shall... scrubbing liquid. The design evaluation shall establish the design exhaust vent stream organic compound... process vent and the overall percent reduction for the collection of non-reactor batch process vents...
Code of Federal Regulations, 2014 CFR
2014-07-01
... process vents that emit hydrogen halide and halogen HAP or HAP metals? 63.2465 Section 63.2465 Protection... hydrogen halide and halogen HAP or HAP metals? (a) You must meet each emission limit in Table 3 to this...) of this section. (b) If any process vents within a process emit hydrogen halide and halogen HAP, you...
Code of Federal Regulations, 2013 CFR
2013-07-01
... process vents that emit hydrogen halide and halogen HAP or HAP metals? 63.2465 Section 63.2465 Protection... hydrogen halide and halogen HAP or HAP metals? (a) You must meet each emission limit in Table 3 to this...) of this section. (b) If any process vents within a process emit hydrogen halide and halogen HAP, you...
Code of Federal Regulations, 2012 CFR
2012-07-01
... process vents that emit hydrogen halide and halogen HAP or HAP metals? 63.2465 Section 63.2465 Protection... hydrogen halide and halogen HAP or HAP metals? (a) You must meet each emission limit in Table 3 to this...) of this section. (b) If any process vents within a process emit hydrogen halide and halogen HAP, you...
40 CFR 63.115 - Process vent provisions-methods and procedures for process vent group determination.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 2 process vent definition of this subpart shall measure either total organic HAP or TOC... either TOC (minus methane and ethane) or organic HAP shall be calculated according to paragraph (c)(3)(ii)(A) or (c)(3)(ii)(B) of this section as applicable. (A) The TOC concentration (CTOC) is the sum of...
Code of Federal Regulations, 2013 CFR
2013-07-01
... collected—PR. d,e Carbon Adsorber f Total regeneration stream mass or volumetric flow during carbon bed regeneration cycle(s), and 1. Record of total regeneration stream mass or volumetric flow for each carbon bed regeneration cycle.2. Record and report the total regeneration stream mass or volumetric flow during each...
Code of Federal Regulations, 2014 CFR
2014-07-01
... operating—PR. d e Carbon Adsorber f Total regeneration stream mass or volumetric flow during carbon bed regeneration cycle(s), and 1. Record of total regeneration stream mass or volumetric flow for each carbon bed regeneration cycle.2. Record and report the total regeneration stream mass or volumetric flow during each...
Code of Federal Regulations, 2010 CFR
2010-07-01
... temperature established in the NCS or operating—PR. d,e Carbon Adsorber f Total regeneration stream mass or volumetric flow during carbon bed regeneration cycle(s), and 1. Record of total regeneration stream mass or volumetric flow for each carbon bed regeneration cycle.2. Record and report the total regeneration stream...
Code of Federal Regulations, 2011 CFR
2011-07-01
... temperature established in the NCS or operating—PR. d,e Carbon Adsorber f Total regeneration stream mass or volumetric flow during carbon bed regeneration cycle(s), and 1. Record of total regeneration stream mass or volumetric flow for each carbon bed regeneration cycle.2. Record and report the total regeneration stream...
Code of Federal Regulations, 2014 CFR
2014-07-01
... collected—PR. d e Carbon Adsorber f Total regeneration stream mass or volumetric flow during carbon bed regeneration cycle(s), and 1. Record of total regeneration stream mass or volumetric flow for each carbon bed regeneration cycle.2. Record and report the total regeneration stream mass or volumetric flow during each...
Code of Federal Regulations, 2012 CFR
2012-07-01
... temperature established in the NCS or operating—PR. d,e Carbon Adsorber f Total regeneration stream mass or volumetric flow during carbon bed regeneration cycle(s), and 1. Record of total regeneration stream mass or volumetric flow for each carbon bed regeneration cycle.2. Record and report the total regeneration stream...
Code of Federal Regulations, 2013 CFR
2013-07-01
... operating—PR. d,e Carbon Adsorber f Total regeneration stream mass or volumetric flow during carbon bed regeneration cycle(s), and 1. Record of total regeneration stream mass or volumetric flow for each carbon bed regeneration cycle.2. Record and report the total regeneration stream mass or volumetric flow during each...
Greenhouse Gas Emissions from Septic Systems in New York State.
Truhlar, Allison M; Rahm, Brian G; Brooks, Rachael A; Nadeau, Sarah A; Makarsky, Erin T; Walter, M Todd
2016-07-01
Onsite septic systems use microbial processes to eliminate organic wastes and nutrients such as nitrogen; these processes can contribute to air pollution through the release of greenhouse gases (GHGs). Current USEPA estimates for septic system GHG emissions are based on one study conducted in north-central California and are limited to methane; therefore, the contribution of these systems to the overall GHG emission budget is unclear. This study quantified and compared septic system GHG emissions from the soil over leach fields and the roof vent, which are the most likely locations for gas emissions during normal septic system operation. At each of eight septic systems, we measured fluxes of CH, CO, and NO using a static chamber method. The roof vent released the majority of septic system gas emissions. In addition, the leach field was a significant source of NO fluxes. Comparisons between leach field and vent emissions suggest that biological processes in the leach field soil may influence the type and quantity of gas released. Overall, our results suggest that (i) revisions are needed in USEPA guidance (e.g., septic systems are not currently listed as a source of NO emissions) and (ii) similar studies representing a wider range of climatic and geographic settings are needed. The total vent, sand filter, and leach field GHG emissions were 0.17, 0.045, and 0.050 t CO-equivalents capita yr, respectively. In total, this represents about 1.5% of the annual carbon footprint of an individual living in the United States. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.
NASA Astrophysics Data System (ADS)
Schaen, A. T.; Ding, K.; Seyfried, W. E.
2013-12-01
Developments in electrochemistry and material science have facilitated the construction of ceramic (YSZ) based chemical sensor systems that can be used to measure and monitor pH and redox in aqueous fluids at elevated temperatures and pressures. In recent years, these sensor systems have been deployed to acquire real-time and time series in-situ data for high-temperature hydrothermal vent fluids at the Main Endeavour Field (Juan de Fuca Ridge), 9oN (East Pacific Rise), and at the ultramafic-hosted Rainbow field (36oN, Mid-Atlantic Ridge). Here we review in-situ pH data measured at these sites and apply these data to estimate the pH of fluids ascending to the seafloor from hydrothermal alteration zones deeper in the crust. In general, in-situ pH measured at virtually all vent sites is well in excess of that measured shipboard owing to the effects of temperature on the distribution of aqueous species and the solubility of metal sulfides, especially Cu and Zn, originally dissolved in the vent fluids. In situ pH measurements determined at MEF (Sully vent) and EPR 9oN (P-vent) in 2005 and 2008 were 4.4 ×0.02 and 5.05×0.05, respectively. The temperature and pressure (seafloor) of the vent fluids at each of the respective sites were 356oC and 220 bar, and 380oC and 250 bar. Plotting these data with respect to fluid density reveals that the in-situ pH of each vent fluid is approximately 1.5 pH units below neutrality. The density-pH (in-situ) correlation, however, is important because it provides a means from which the vent fluids were derived. Using dissolved silica and chloride from fluid samples at the MEF (Sully) suggest T/P conditions of approximately 435oC, 380 bar, based on quartz-fluid and NaCl-H2O systems. At the fluid density calculated for these conditions, pH (in-situ) is predicted to be ~6.2. Attempts are presently underway to assess the effect of the calculated pH on metal sulfide and silicate (e.g., plagioclase, chlorite) solubility in comparison with constraints imposed by the full range of chemical components in the vent fluids sampled and analyzed in association with pH (in-situ) measurements. Since pH is a master variable in all geochemical systems, the novel approach proposed here may provide new insight on hydrothermal alteration processes at conditions difficult or impossible to assess by more traditional means, ultimately influencing hydrothermal fluid fluxes.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Pollutants: Miscellaneous Organic Chemical Manufacturing Pt. 63, Subpt. FFFF, Table 1 Table 1 to Subpart FFFF... continuous process vent a. Not applicable i. Reduce emissions of total organic HAP by ≥98 percent by weight or to an outlet process concentration ≤20 ppmv as organic HAP or TOC by venting emissions through a...
40 CFR 60.562-1 - Standards: Process emissions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Compound (VOC) Emissions from the Polymer Manufacturing Industry § 60.562-1 Standards: Process emissions... vent stream from a control device shall have car-sealed opened all valves in the vent system from the emission source to the control device and car-sealed closed all valves in vent system that would lead the...
Code of Federal Regulations, 2012 CFR
2012-07-01
... process vents in Table 1 or 2 to this subpart. You must meet the CPMS requirements in paragraph (c) of... parameter specified in Table 5 to this subpart for each process vent control device specified in § 63.11925(b) that is used to comply with the emission limits for process vents in Table 1 or 2 to this subpart...
Code of Federal Regulations, 2014 CFR
2014-07-01
... process vents in Table 1 or 2 to this subpart. You must meet the CPMS requirements in paragraph (c) of... parameter specified in Table 5 to this subpart for each process vent control device specified in § 63.11925(b) that is used to comply with the emission limits for process vents in Table 1 or 2 to this subpart...
Code of Federal Regulations, 2013 CFR
2013-07-01
... process vents in Table 1 or 2 to this subpart. You must meet the CPMS requirements in paragraph (c) of... parameter specified in Table 5 to this subpart for each process vent control device specified in § 63.11925(b) that is used to comply with the emission limits for process vents in Table 1 or 2 to this subpart...
Cyclic membrane separation process
Nemser, Stuart M.
2005-05-03
A cyclic process for controlling environmental emissions of volatile organic compounds (VOC) from vapor recovery in storage and dispensing operations of liquids maintains a vacuum in the storage tank ullage. In the first part of a two-part cyclic process ullage vapor is discharged through a vapor recovery system in which VOC are stripped from vented gas with a selectively gas permeable membrane. In the second part, the membrane is inoperative while gas pressure rises in the ullage. In one aspect of this invention, a vacuum is drawn in the membrane separation unit thus reducing overall VOC emissions.
Cyclic membrane separation process
Bowser, John
2004-04-13
A cyclic process for controlling environmental emissions of volatile organic compounds (VOC) from vapor recovery in storage and dispensing operations of liquids maintains a vacuum in the storage tank ullage. In one of a two-part cyclic process ullage vapor is discharged through a vapor recovery system in which VOC are stripped from vented gas with a selectively gas permeable membrane. In the other part, the membrane is inoperative while gas pressure rises in the ullage. Ambient air is charged to the membrane separation unit during the latter part of the cycle.
NASA Astrophysics Data System (ADS)
Maeno, Fukashi; Nakada, Setsuya; Oikawa, Teruki; Yoshimoto, Mitsuhiro; Komori, Jiro; Ishizuka, Yoshihiro; Takeshita, Yoshihiro; Shimano, Taketo; Kaneko, Takayuki; Nagai, Masashi
2016-05-01
The phreatic eruption at Ontake volcano on 27 September 2014, which caused the worst volcanic disaster in the past half-century in Japan, was reconstructed based on observations of the proximal pyroclastic density current (PDC) and fallout deposits. Witness observations were also used to clarify the eruption process. The deposits are divided into three major depositional units (Units A, B, and C) which are characterized by massive, extremely poorly sorted, and multimodal grain-size distribution with 30-50 wt% of fine ash (silt-clay component). The depositional condition was initially dry but eventually changed to wet. Unit A originated from gravity-driven turbulent PDCs in the relatively dry, vent-opening phase. Unit B was then produced mainly by fallout from a vigorous moist plume during vent development. Unit C was derived from wet ash fall in the declining stage. Ballistic ejecta continuously occurred during vent opening and development. As observed in the finest population of the grain-size distribution, aggregate particles were formed throughout the eruption, and the effect of water in the plume on the aggregation increased with time and distance. Based on the deposit thickness, duration, and grain-size data, and by applying a scaling analysis using a depth-averaged model of turbulent gravity currents, the particle concentration and initial flow speed of the PDC at the summit area were estimated as 2 × 10-4-2 × 10-3 and 24-28 m/s, respectively. The tephra thinning trend in the proximal area shows a steeper slope than in similar-sized magmatic eruptions, indicating a large tephra volume deposited over a short distance owing to the wet dispersal conditions. The Ontake eruption provided an opportunity to examine the deposits from a phreatic eruption with a complex eruption sequence that reflects the effect of external water on the eruption dynamics.
Code of Federal Regulations, 2010 CFR
2010-07-01
... compounds (TOC) or nonmethane TOC from your process vent by 98 percent by weight using a control device or... stringent The mass emission reduction of nonmethane TOC measured by Method 25 over the period of the... mass emission reduction of TOC measured by Method 25A (or nonmethane TOC measured by Methods 25A and 18...
Vent Processes and Deposits of a Hiatus in a Violent Eruption: Quilotoa Volcano, Ecuador
NASA Astrophysics Data System (ADS)
Best, J. A.; Bustillos, J.; Ort, M. H.; Cashman, K. V.; Mothes, P. A.; di Muro, A.; Rosi, M.
2010-12-01
The 800 BP eruption of Quilotoa volcano, Ecuador, produced two plinian eruptions separated by a short (days-weeks) hiatus. Units 1 and 3 (U1 and U3) of the eruption correspond to the first and second Plinian eruptions, respectively, and produced fallout and pyroclastic density currents. Unit 2 (U2) records processes during the hiatus and consists of three subunits: U2a, U2b, and U2c. 147 tephra samples of U1, U2, and U3 were collected from 25 sites from around the volcano. Thickness and grain-size features were described, with particular attention paid to U2, in order to characterize the processes that occurred during the eruptive hiatus. Grain-size and componentry analysis of a subset of these samples reveals a number of trends. The upper part of U1 is massive and normally graded at its top, 32-45 % dominantly vitric ash ≤ 3.0 φ, and likely represents the clearing of the air at the end of the first plinian eruption. U2a, present out to a maximum of 7 km from the vent, has a polymodal distribution with a large fraction of 4.0 φ and finer vitric material. Dune forms occur in this unit, which are interpreted to be the product of surges. The areal distribution of U2a is constrained by topography, whereas U2b is not. U2b is coarser overall with alternating fine- (2-3φ) and coarse- (1-2φ) grained layers. The beds, both coarse and fine, have a near-bimodal grain-size distribution and normal grading. U2b is interpreted as a fall deposit. The U2a/U2b contact is gradational in that 0-2 beds of U2b material occur within the uppermost U2a beds at proximal localities, indicating vent conditions for both briefly coexisted. U2c is a <2-cm-thick vitric ash bed with sparse dense juvenile vitric lapilli. These lapilli also occur in the overlying basal U3 fallout, which has a polymodal grain-size distribution. U2b is characteristically orange in color due to the dust that loosely covers the grains. Hydrothermal activity within the vent is likely the source of this staining, with the simultaneous milling of the weakened material producing the orange dust. We interpret the dense vitric lapilli ≥ -2.0 φ of U2c as being from an explosion through a lava dome, and thus they indicate that the eruption was continuous from U2c through U3. Our current hypothesis is that, as the U1 eruption ended, magma stalled deep in the conduit and degassed hot acidic gas that streamed through the material clogging the vent. This elutriated vitric material that eventually formed a cap on the system. As the U3 magma began its ascent, gas flux increased, leading to explosions that gradually removed the vitric cap and deposited the vitric U2a. Then, more continuous gas streaming led to the development of a pulsatory eruption column that carried hot crystals and vitric grains from the vent clog into a convecting column and eventual deposition as U2b fallout, which was then followed by the establishment of the U3 eruption column.
2009-03-11
CAPE CANAVERAL, Fla. – Seen in the photo is the hydrogen vent line attached to the Ground Umbilical Carrier Plate on space shuttle Discovery's external fuel tank. The shuttle is on Launch Pad 39A at NASA's Kennedy Space Center in Florida. A leak of hydrogen at the location during tanking caused the STS-119 mission to be scrubbed at 2:36 p.m. March 11. The vent line is at the intertank and is the overboard vent to the pad and the flare stack where the vented hydrogen is burned off. Mission management teams believe they have sufficient understanding of the repair plan to continue toward a March 15 launch at 7:43 p.m. EDT. Photo courtesy of United Space Alliance
Assessment and control design for steam vent noise in an oil refinery.
Monazzam, Mohammad Reza; Golmohammadi, Rostam; Nourollahi, Maryam; Momen Bellah Fard, Samaneh
2011-06-13
Noise is one of the most important harmful agents in work environment. Noise pollution in oil refinery industries is related to workers' health. This study aimed to determine the overall noise pollution of an oil refinery operation and its frequency analysis to determine the control plan for a vent noise in these industries. This experimental study performed in control unit of Tehran Oil Refinery in 2008. To determine the noise distributions, environmental noise measurements were carried out by lattice method according to basic information and technical process. The sound pressure level and frequency distribution was measured for each study sources subject separately was performed individually. According to the vent's specification, the measured steam noise characteristics reviewed and compared to the theoretical results of steam noise estimation. Eventually, a double expansion muffler was designed. Data analysis and graphical design were carried out using Excel software. The results of environmental noise measurements indicated that the level of sound pressure was above the national permitted level (85 dB (A)). The Mean level of sound pressure of the studied steam jet was 90.3 dB (L). The results of noise frequency analysis for the steam vents showed that the dominant frequency was 4000 Hz. To obtain 17 dB noise reductions, a double chamber aluminum muffler with 500 mm length and 200 mm diameter consisting pipe drilled was designed. The characteristics of steam vent noise were separated from other sources, a double expansion muffler was designed using a new method based on the level of steam noise, and principle sound frequency, a double expansion muffler was designed.
EXPOSED BEAM AND VINYL VENTED SOFFIT MATERIAL IN THE CARPORT ...
EXPOSED BEAM AND VINYL VENTED SOFFIT MATERIAL IN THE CARPORT ON THE SOUTHEAST SIDE OF THE UNIT - Camp H.M. Smith and Navy Public Works Center Manana Title VII (Capehart) Housing, U-Shaped Two-Bedroom Single-Family Type 6, Birch Circle, Elm Drive, Elm Circle, and Date Drive, Pearl City, Honolulu County, HI
Kozlowski, L T; O'Connor, R J; Giovino, G A; Whetzel, C A; Pauly, J; Cummings, K M
2006-01-01
Filter ventilation is the dominant design feature of the modern cigarette that determines yields of tar, nicotine, and carbon monoxide on smoking machine tests. The commercial use of filter ventilation was precipitated by the 1964 United States Surgeon‐General's report, further advanced by the adoption of an official Federal Trade Commission test in 1967, and still further advanced by the inclusion of a gas phase (carbon monoxide) measure in 1979. The first vented‐filter brand on the market in the United States (Carlton) in 1964 and the second major vented‐filter brand (True) in 1966 illustrate this. Ultimately, filter ventilation became a virtually required way to make very low tar cigarettes (less than 10 mg or, even more so, less than 5 mg tar). The key to the lower tar cigarette was not, in effect, the advanced selective filtration design characteristics or sophisticated tobacco selection or processing as envisioned by experts (although these techniques were and are used); the key to the very much lower tar cigarette was simply punching holes in the filter. We propose that the banning of filter vents, coupled with low maximum standard tar, nicotine, and carbon monoxide yields, would contribute to making cigarettes much less palatable and foster smoking cessation or the use of clearly less hazardous nicotine delivery systems. It may be necessary to link low maximum yields with the banning of filter ventilation to achieve public health benefit from such maxima. PMID:16728759
Copley, J. T.; Marsh, L.; Glover, A. G.; Hühnerbach, V.; Nye, V. E.; Reid, W. D. K.; Sweeting, C. J.; Wigham, B. D.; Wiklund, H.
2016-01-01
The Southwest Indian Ridge is the longest section of very slow to ultraslow-spreading seafloor in the global mid-ocean ridge system, but the biogeography and ecology of its hydrothermal vent fauna are previously unknown. We collected 21 macro- and megafaunal taxa during the first Remotely Operated Vehicle dives to the Longqi vent field at 37° 47′S 49° 39′E, depth 2800 m. Six species are not yet known from other vents, while six other species are known from the Central Indian Ridge, and morphological and molecular analyses show that two further polychaete species are shared with vents beyond the Indian Ocean. Multivariate analysis of vent fauna across three oceans places Longqi in an Indian Ocean province of vent biogeography. Faunal zonation with increasing distance from vents is dominated by the gastropods Chrysomallon squamiferum and Gigantopelta aegis, mussel Bathymodiolus marisindicus, and Neolepas sp. stalked barnacle. Other taxa occur at lower abundance, in some cases contrasting with abundances at other vent fields, and δ13C and δ15N isotope values of species analysed from Longqi are similar to those of shared or related species elsewhere. This study provides baseline ecological observations prior to mineral exploration activities licensed at Longqi by the United Nations. PMID:27966649
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-12-31
The feasibility of utilizing a biological process to reduce methane emissions from coal mines and to produce valuable single cell protein (SCP) and/or methanol as a product has been demonstrated. The quantities of coal mine methane from vent gas, gob wells, premining wells and abandoned mines have been determined in order to define the potential for utilizing mine gases as a resource. It is estimated that 300 MMCFD of methane is produced in the United States at a typical concentration of 0.2-0.6 percent in ventilation air. Of this total, almost 20 percent is produced from the four Jim Walter Resourcesmore » (JWR) mines, which are located in very gassy coal seams. Worldwide vent gas production is estimated at 1 BCFD. Gob gas methane production in the U.S. is estimated to be 38 MMCFD. Very little gob gas is produced outside the U.S. In addition, it is estimated that abandoned mines may generate as much as 90 MMCFD of methane. In order to make a significant impact on coal mine methane emissions, technology which is able to utilize dilute vent gases as a resource must be developed. Purification of the methane from the vent gases would be very expensive and impractical. Therefore, the process application must be able to use a dilute methane stream. Biological conversion of this dilute methane (as well as the more concentrated gob gases) to produce single cell protein (SCP) and/or methanol has been demonstrated in the Bioengineering Resources, Inc. (BRI) laboratories. SCP is used as an animal feed supplement, which commands a high price, about $0.11 per pound.« less
40 CFR 265.1032 - Standards: Process vents.
Code of Federal Regulations, 2010 CFR
2010-07-01
... owner or operator of a fa-cil-ity with process vents associated with distillation, fractionation, thin-film evaporation, solvent extraction or -air or steam stripping operations man-aging haz-ard-ous wastes...
40 CFR 265.1032 - Standards: Process vents.
Code of Federal Regulations, 2011 CFR
2011-07-01
... owner or operator of a fa-cil-ity with process vents associated with distillation, fractionation, thin-film evaporation, solvent extraction or -air or steam stripping operations man-aging haz-ard-ous wastes...
2009-03-11
CAPE CANAVERAL, Fla. – A closeup of the 7-inch quick disconnect that will be replaced on the hydrogen vent line to the Ground Umbilical Carrier Plate of space shuttle Discovery's external fuel tank. The replacement will be made on Launch Pad 39A at NASA's Kennedy Space Center in Florida. A leak of hydrogen at the site during fueling caused the STS-119 mission to be scrubbed at 2:36 p.m. March 11. The vent line is at the intertank and is the overboard vent to the pad and the flare stack where the vented hydrogen is burned off. Mission management teams believe they have sufficient understanding of the repair plan to continue toward a March 15 launch at 7:43 p.m. EDT. Photo courtesy of United Space Alliance
40 CFR 63.7885 - What are the general standards I must meet for my affected process vents?
Code of Federal Regulations, 2010 CFR
2010-07-01
... Remediation General Standards § 63.7885 What are the general standards I must meet for my affected process...) You determine for the remediation material treated or managed by the process vented through the...
Convective transport over the central United States and its role in regional CO and ozone budgets
NASA Technical Reports Server (NTRS)
Thompson, Anne M.; Pickering, Kenneth E.; Dickerson, Russell R.; Ellis, William G., Jr.; Jacob, Daniel J.; Scala, John R.; Tao, Wei-Kuo; Mcnamara, Donna P.; Simpson, Joanne
1994-01-01
We have constructed a regional budget for boundary layer carbon monoxide over the central United States (32.5 deg - 50 deg N, 90 deg - 105 deg W), emphasizing a detailed evaluation of deep convective vertical fluxes appropriate for the month of June. Deep convective venting of the boundary layer (upward) dominates other components of the CO budget, e.g., downward convective transport, loss of CO by oxidation, anthropogenic emissions, and CO produced from oxidation of methane, isoprene, and anthropogenic nonmethane hydrocarbons (NMHCs). Calculations of deep convective venting are based on the method pf Pickering et al.(1992a) which uses a satellite-derived deep convective cloud climatology along with transport statistics from convective cloud model simulations of observed prototype squall line events. This study uses analyses of convective episodes in 1985 and 1989 and CO measurements taken during several midwestern field campaigns. Deep convective venting of the boundary layer over this moderately polluted region provides a net (upward minus downward) flux of 18.1 x 10(exp 8) kg CO/month to the free troposphere during early summer. Shallow cumulus and synoptic-scale weather systems together make a comparable contribution (total net flux 16.2 x 10(exp 8) kg CO/month). Boundary layer venting of CO with other O3 precursors leads to efficient free troposheric O3 formation. We estimate that deep convective transport of CO and other precursors over the central United States in early summer leads to a gross production of 0.66 - 1.1 Gmol O3/d in good agreement with estimates of O3 production from boundary layer venting in a continental-scale model (Jacob et al., 1993a, b). On this respect the central U.S. region acts as s `chimney' for the country, and presumably this O3 contributes to high background levels of O3 in the eastern United States and O3 export to the North Atlantic.
Andrew Fowler
2015-10-01
Compilation of rare earth element and associated major and minor dissolved constituent analytical data for USA geothermal fields and global seafloor hydrothermal vents. Data is in original units. Reference to and use of this data should be attributed to the original authors and publications according to the provisions outlined therein.
40 CFR 60.482-10 - Standards: Closed vent systems and control devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Performance for Equipment Leaks of VOC in the Synthetic Organic Chemicals Manufacturing Industry for which... unit shutdown. (i) If a vapor collection system or closed vent system is operated under a vacuum, it is... would be exposed to an imminent or potential danger as a consequence of complying with paragraphs (f)(1...
NASA Astrophysics Data System (ADS)
Kaneko, Takayuki; Maeno, Fukashi; Nakada, Setsuya
2016-05-01
The sudden eruption of Mount Ontake on September 27, 2014, led to a tragedy that caused more than 60 fatalities including missing persons. In order to mitigate the potential risks posed by similar volcano-related disasters, it is vital to have a clear understanding of the activity status and progression of eruptions. Because the erupted material was largely disturbed while access was strictly prohibited for a month, we analyzed the aerial photographs taken on September 28. The results showed that there were three large vents in the bottom of the Jigokudani valley on September 28. The vent in the center was considered to have been the main vent involved in the eruption, and the vents on either side were considered to have been formed by non-explosive processes. The pyroclastic flows extended approximately 2.5 km along the valley at an average speed of 32 km/h. The absence of burned or fallen trees in this area indicated that the temperatures and destructive forces associated with the pyroclastic flow were both low. The distribution of ballistics was categorized into four zones based on the number of impact craters per unit area, and the furthest impact crater was located 950 m from the vents. Based on ballistic models, the maximum initial velocity of the ejecta was estimated to be 111 m/s. Just after the beginning of the eruption, very few ballistic ejecta had arrived at the summit, even though the eruption plume had risen above the summit, which suggested that a large amount of ballistic ejecta was expelled from the volcano several tens-of-seconds after the beginning of the eruption. This initial period was characterized by the escape of a vapor phase from the vents, which then caused the explosive eruption phase that generated large amounts of ballistic ejecta via sudden decompression of a hydrothermal reservoir.
Response of Posidonia oceanica seagrass and its epibiont communities to ocean acidification.
Guilini, Katja; Weber, Miriam; de Beer, Dirk; Schneider, Matthias; Molari, Massimiliano; Lott, Christian; Bodnar, Wanda; Mascart, Thibaud; De Troch, Marleen; Vanreusel, Ann
2017-01-01
The unprecedented rate of CO2 increase in our atmosphere and subsequent ocean acidification (OA) threatens coastal ecosystems. To forecast the functioning of coastal seagrass ecosystems in acidified oceans, more knowledge on the long-term adaptive capacities of seagrass species and their epibionts is needed. Therefore we studied morphological characteristics of Posidonia oceanica and the structure of its epibiont communities at a Mediterranean volcanic CO2 vent off Panarea Island (Italy) and performed a laboratory experiment to test the effect of OA on P. oceanica photosynthesis and its potential buffering capacity. At the study site east of Basiluzzo Islet, venting of CO2 gas was controlled by tides, resulting in an average pH difference of 0.1 between the vent and reference site. P. oceanica shoot and leaf density was unaffected by these levels of OA, although shorter leaves at the vent site suggest increased susceptibility to erosion, potentially by herbivores. The community of sessile epibionts differed in composition and was characterized by a higher species richness at the vent site, though net epiphytic calcium carbonate concentration was similar. These findings suggest a higher ecosystem complexity at the vent site, which may have facilitated the higher diversity of copepods in the otherwise unaffected motile epibiont community. In the laboratory experiment, P. oceanica photosynthesis increased with decreasing pHT (7.6, 6.6, 5.5), which induced an elevated pH at the leaf surfaces of up to 0.5 units compared to the ambient seawater pHT of 6.6. This suggests a temporary pH buffering in the diffusive boundary layer of leaves, which could be favorable for epibiont organisms. The results of this multispecies study contribute to understanding community-level responses and underlying processes in long-term acidified conditions. Increased replication and monitoring of physico-chemical parameters on an annual scale are, however, recommended to assure that the biological responses observed during a short period reflect long-term dynamics of these parameters.
Response of Posidonia oceanica seagrass and its epibiont communities to ocean acidification
Weber, Miriam; de Beer, Dirk; Schneider, Matthias; Molari, Massimiliano; Lott, Christian; Bodnar, Wanda; Mascart, Thibaud; De Troch, Marleen; Vanreusel, Ann
2017-01-01
The unprecedented rate of CO2 increase in our atmosphere and subsequent ocean acidification (OA) threatens coastal ecosystems. To forecast the functioning of coastal seagrass ecosystems in acidified oceans, more knowledge on the long-term adaptive capacities of seagrass species and their epibionts is needed. Therefore we studied morphological characteristics of Posidonia oceanica and the structure of its epibiont communities at a Mediterranean volcanic CO2 vent off Panarea Island (Italy) and performed a laboratory experiment to test the effect of OA on P. oceanica photosynthesis and its potential buffering capacity. At the study site east of Basiluzzo Islet, venting of CO2 gas was controlled by tides, resulting in an average pH difference of 0.1 between the vent and reference site. P. oceanica shoot and leaf density was unaffected by these levels of OA, although shorter leaves at the vent site suggest increased susceptibility to erosion, potentially by herbivores. The community of sessile epibionts differed in composition and was characterized by a higher species richness at the vent site, though net epiphytic calcium carbonate concentration was similar. These findings suggest a higher ecosystem complexity at the vent site, which may have facilitated the higher diversity of copepods in the otherwise unaffected motile epibiont community. In the laboratory experiment, P. oceanica photosynthesis increased with decreasing pHT (7.6, 6.6, 5.5), which induced an elevated pH at the leaf surfaces of up to 0.5 units compared to the ambient seawater pHT of 6.6. This suggests a temporary pH buffering in the diffusive boundary layer of leaves, which could be favorable for epibiont organisms. The results of this multispecies study contribute to understanding community-level responses and underlying processes in long-term acidified conditions. Increased replication and monitoring of physico-chemical parameters on an annual scale are, however, recommended to assure that the biological responses observed during a short period reflect long-term dynamics of these parameters. PMID:28792960
2018-01-01
for Mach 14 possibly degrading seals ability to contain pressure due to exposure to high temperatures. A different solution for Mach 14 case will be...AEDC-TR-18-H-1 Development of High Temperature (3400°F) and High Pressure (27,000 PSI) Gas Venting Process for Nitrogen Batch...Development of High Temperature (3400°F) and High Pressure (27,000 PSI) Gas Venting Process for Nitrogen Batch Heater FA9101-10-D-0001-0010 5b. GRANT
NASA Astrophysics Data System (ADS)
Wang, Lei; Li, Yanzhong; Zhang, Feini; Ma, Yuan
2015-12-01
Two finite difference computer models, aiming at the process predictions of no-vent fill in normal gravity and microgravity environments respectively, are developed to investigate the filling performance in a liquid hydrogen (LH2) tank. In the normal gravity case model, the tank/fluid system is divided into five control volume including ullage, bulk liquid, gas-liquid interface, ullage-adjacent wall, and liquid-adjacent wall. In the microgravity case model, vapor-liquid thermal equilibrium state is maintained throughout the process, and only two nodes representing fluid and wall regions are applied. To capture the liquid-wall heat transfer accurately, a series of heat transfer mechanisms are considered and modeled successively, including film boiling, transition boiling, nucleate boiling and liquid natural convection. The two models are validated by comparing their prediction with experimental data, which shows good agreement. Then the two models are used to investigate the performance of no-vent fill in different conditions and several conclusions are obtained. It shows that in the normal gravity environment the no-vent fill experiences a continuous pressure rise during the whole process and the maximum pressure occurs at the end of the operation, while the maximum pressure of the microgravity case occurs at the beginning stage of the process. Moreover, it seems that increasing inlet mass flux has an apparent influence on the pressure evolution of no-vent fill process in normal gravity but a little influence in microgravity. The larger initial wall temperature brings about more significant liquid evaporation during the filling operation, and then causes higher pressure evolution, no matter the filling process occurs under normal gravity or microgravity conditions. Reducing inlet liquid temperature can improve the filling performance in normal gravity, but cannot significantly reduce the maximum pressure in microgravity. The presented work benefits the understanding of the no-vent fill performance and may guide the design of on-orbit no-vent fill system.
Code of Federal Regulations, 2013 CFR
2013-07-01
... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS... Pollutants: Site Remediation Process Vents § 63.7890 What emissions limitations and work practice standards...
Code of Federal Regulations, 2011 CFR
2011-07-01
... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS... Pollutants: Site Remediation Process Vents § 63.7890 What emissions limitations and work practice standards...
Code of Federal Regulations, 2014 CFR
2014-07-01
... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS... Pollutants: Site Remediation Process Vents § 63.7890 What emissions limitations and work practice standards...
Code of Federal Regulations, 2012 CFR
2012-07-01
... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS... Pollutants: Site Remediation Process Vents § 63.7890 What emissions limitations and work practice standards...
Holocene volcanism of the upper McKenzie River catchment, central Oregon Cascades, USA
Deligne, Natalia I.; Conrey, Richard M.; Cashman, Katharine V.; Champion, Duane E.; Amidon, William H.
2016-01-01
To assess the complexity of eruptive activity within mafic volcanic fields, we present a detailed geologic investigation of Holocene volcanism in the upper McKenzie River catchment in the central Oregon Cascades, United States. We focus on the Sand Mountain volcanic field, which covers 76 km2 and consists of 23 vents, associated tephra deposits, and lava fields. We find that the Sand Mountain volcanic field was active for a few decades around 3 ka and involved at least 13 eruptive units. Despite the small total volume erupted (∼1 km3 dense rock equivalent [DRE]), Sand Mountain volcanic field lava geochemistry indicates that erupted magmas were derived from at least two, and likely three, different magma sources. Single units erupted from one or more vents, and field data provide evidence of both vent migration and reoccupation. Overall, our study shows that mafic volcanism was clustered in space and time, involved both explosive and effusive behavior, and tapped several magma sources. These observations provide important insights on possible future hazards from mafic volcanism in the central Oregon Cascades.
40 CFR 63.1326 - Batch process vents-recordkeeping provisions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... (CONTINUED) National Emission Standards for Hazardous Air Pollutant Emissions: Group IV Polymers and Resins § 63.1326 Batch process vents—recordkeeping provisions. (a) Group determination records for batch... this section for each batch process vent subject to the group determination procedures of § 63.1323...
NASA Technical Reports Server (NTRS)
Wilson, Timmy R.; Beech, Geoffrey; Johnston, Ian
2009-01-01
The NESC Assessment Team reviewed a computer simulation of the LC-39 External Tank (ET) GH2 Vent Umbilical system developed by United Space Alliance (USA) for the Space Shuttle Program (SSP) and designated KSC Analytical Tool ID 451 (KSC AT-451). The team verified that the vent arm kinematics were correctly modeled, but noted that there were relevant system sensitivities. Also, the structural stiffness used in the math model varied somewhat from the analytic calculations. Results of the NESC assessment were communicated to the model developers.
NASA Technical Reports Server (NTRS)
Jones, Jeff; Hoffman, Ron; Harvey, Craig; Bowen, C. K.; Hudy, C. E.; Tuxhorn, Jennifer; Gernhardt, Mike; Scheuring, Richard A.
2007-01-01
The goal of this study is to determine the role that moisture plays in the injury to the fingers and fingernails during EVA training operations in the Neutral Buoyancy Laboratory. Current Extravehicular Mobility Unit (EMU, with a PLSS) as configured in the NBL was used for all testing and a vent tube was extended down a single arm of the crewmember during the test; vent tube was moved between left and right arm to serve as experimental condition being investigated and the other arm served as control condition.
40 CFR 63.491 - Batch front-end process vents-recordkeeping requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... CATEGORIES National Emission Standards for Hazardous Air Pollutant Emissions: Group I Polymers and Resins § 63.491 Batch front-end process vents—recordkeeping requirements. (a) Group determination records for...) through (a)(6) of this section for each batch front-end process vent subject to the group determination...
40 CFR 63.487 - Batch front-end process vents-reference control technology.
Code of Federal Regulations, 2011 CFR
2011-07-01
... control technology. 63.487 Section 63.487 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... CATEGORIES National Emission Standards for Hazardous Air Pollutant Emissions: Group I Polymers and Resins § 63.487 Batch front-end process vents—reference control technology. (a) Batch front-end process vents...
40 CFR 63.491 - Batch front-end process vents-recordkeeping requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... CATEGORIES National Emission Standards for Hazardous Air Pollutant Emissions: Group I Polymers and Resins § 63.491 Batch front-end process vents—recordkeeping requirements. (a) Group determination records for...) through (a)(6) of this section for each batch front-end process vent subject to the group determination...
40 CFR 63.491 - Batch front-end process vents-recordkeeping requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... CATEGORIES National Emission Standards for Hazardous Air Pollutant Emissions: Group I Polymers and Resins § 63.491 Batch front-end process vents—recordkeeping requirements. (a) Group determination records for...) through (a)(6) of this section for each batch front-end process vent subject to the group determination...
40 CFR 63.491 - Batch front-end process vents-recordkeeping requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... CATEGORIES National Emission Standards for Hazardous Air Pollutant Emissions: Group I Polymers and Resins § 63.491 Batch front-end process vents—recordkeeping requirements. (a) Group determination records for...) through (a)(6) of this section for each batch front-end process vent subject to the group determination...
Code of Federal Regulations, 2014 CFR
2014-07-01
... permit limit applicable to the process vent. (4) Design analysis based on accepted chemical engineering principles, measurable process parameters, or physical or chemical laws or properties. (5) All data... tested for vapor tightness. (b) Engineering assessment. Engineering assessment to determine if a vent...
Code of Federal Regulations, 2012 CFR
2012-07-01
... permit limit applicable to the process vent. (4) Design analysis based on accepted chemical engineering principles, measurable process parameters, or physical or chemical laws or properties. (5) All data... tested for vapor tightness. (b) Engineering assessment. Engineering assessment to determine if a vent...
Code of Federal Regulations, 2011 CFR
2011-07-01
... permit limit applicable to the process vent. (4) Design analysis based on accepted chemical engineering principles, measurable process parameters, or physical or chemical laws or properties. (5) All data... tested for vapor tightness. (b) Engineering assessment. Engineering assessment to determine if a vent...
Code of Federal Regulations, 2010 CFR
2010-07-01
... permit limit applicable to the process vent. (4) Design analysis based on accepted chemical engineering principles, measurable process parameters, or physical or chemical laws or properties. (5) All data... tested for vapor tightness. (b) Engineering assessment. Engineering assessment to determine if a vent...
Code of Federal Regulations, 2013 CFR
2013-07-01
... permit limit applicable to the process vent. (4) Design analysis based on accepted chemical engineering principles, measurable process parameters, or physical or chemical laws or properties. (5) All data... tested for vapor tightness. (b) Engineering assessment. Engineering assessment to determine if a vent...
Using Volcanic Lightning Measurements to Discern Variations in Explosive Volcanic Activity
NASA Astrophysics Data System (ADS)
Behnke, S. A.; Thomas, R. J.; McNutt, S. R.; Edens, H. E.; Krehbiel, P. R.; Rison, W.
2013-12-01
VHF observations of volcanic lightning have been made during the recent eruptions of Augustine Volcano (2006, Alaska, USA), Redoubt Volcano (2009, Alaska, USA), and Eyjafjallajökull (2010, Iceland). These show that electrical activity occurs both on small scales at the vent of the volcano, concurrent with an eruptive event and on large scales throughout the eruption column during and subsequent to an eruptive event. The small-scale discharges at the vent of the volcano are often referred to as 'vent discharges' and are on the order of 10-100 meters in length and occur at rates on the order of 1000 per second. The high rate of vent discharges produces a distinct VHF signature that is sometimes referred to as 'continuous RF' radiation. VHF radiation from vent discharges has been observed at sensors placed as far as 100 km from the volcano. VHF and infrasound measurements have shown that vent discharges occur simultaneously with the onset of eruption, making their detection an unambiguous indicator of explosive volcanic activity. The fact that vent discharges are observed concurrent with explosive volcanic activity indicates that volcanic ejecta are charged upon eruption. VHF observations have shown that the intensity of vent discharges varies between eruptive events, suggesting that fluctuations in eruptive processes affect the electrification processes giving rise to vent discharges. These fluctuations may be variations in eruptive vigor or variations in the type of eruption; however, the data obtained so far do not show a clear relationship between eruption parameters and the intensity or occurrence of vent discharges. Further study is needed to clarify the link between vent discharges and eruptive behavior, such as more detailed lightning observations concurrent with tephra measurements and other measures of eruptive strength. Observations of vent discharges, and volcanic lightning observations in general, are a valuable tool for volcano monitoring, providing a method for rapid detection of volcanic activity in real-time.
CMO Site: Ocean Instrumentation
1997-02-01
in the Gulf of Mexico during FF1 DATA research cruises in 1991-1995 and Alvin and Nautile on the East Pacific CALL OR FAX FOR ALL SPECS Rise to a depth...journey. " Hydrothermal plumes rise up building up muddy capes and head- water percolates down through these from the vent for maybe several 100 lands, or...pressure * data presented in engineering units * internal data processing 1..1.. SFNSORTEC A!S Industrivn. 3. P.O. Box 165 N -2020 Skedsmokorset, NORWAY
Living with the Heat. Submarine Ring of Fire--Grades 5-6. Hydrothermal Vent Ecology.
ERIC Educational Resources Information Center
National Oceanic and Atmospheric Administration (DOC), Rockville, MD.
This activity is designed to teach about hydrothermal vent ecology. Students are expected to describe how hydrothermal vents are formed and characterize the physical conditions at these sites, explain chemosynthesis and contrast this process with photosynthesis, identify autotrophic bacteria as the basis for food webs in hydrothermal vent…
40 CFR 63.1260 - Reporting requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... process vents as required in § 63.1257(d)(2)(ii). (6) Data and other information supporting the determination of annual average concentrations by process simulation as required in § 63.1257(e)(1)(ii). (7... must be performed while a process with a vent subject to § 63.1254(a)(3) will be operating. (g...
NASA Astrophysics Data System (ADS)
Knuth, F.; Crone, T. J.; Marburg, A.
2017-12-01
The Ocean Observatories Initiative's (OOI) Cabled Array is delivering real-time high-definition video data from an HD video camera (CAMHD), installed at the Mushroom hydrothermal vent in the ASHES hydrothermal vent field within the caldera of Axial Seamount, an active submarine volcano located approximately 450 kilometers off the coast of Washington at a depth of 1,542 m. Every three hours the camera pans, zooms and focuses in on nine distinct scenes of scientific interest across the vent, producing 14-minute-long videos during each run. This standardized video sampling routine enables scientists to programmatically analyze the content of the video using automated image analysis techniques. Each scene-specific time series dataset can service a wide range of scientific investigations, including the estimation of bacterial flux into the system by quantifying chemosynthetic bacterial clusters (floc) present in the water column, relating periodicity in hydrothermal vent fluid flow to earth tides, measuring vent chimney growth in response to changing hydrothermal fluid flow rates, or mapping the patterns of fauna colonization, distribution and composition across the vent over time. We are currently investigating the seventh scene in the sampling routine, focused on the bacterial mat covering the seafloor at the base of the vent. We quantify the change in bacterial mat coverage over time using image analysis techniques, and examine the relationship between mat coverage, fluid flow processes, episodic chimney collapse events, and other processes observed by Cabled Array instrumentation. This analysis is being conducted using cloud-enabled computer vision processing techniques, programmatic image analysis, and time-lapse video data collected over the course of the first CAMHD deployment, from November 2015 to July 2016.
Code of Federal Regulations, 2010 CFR
2010-07-01
...(b)(2), you maintain emissions of TOC (minus methane and ethane) from all affected process vents at...), you maintain that the emissions of TOC (minus methane and ethane) from all affected process vents are...
40 CFR 63.110 - Applicability.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Vents, Storage Vessels, Transfer Operations, and Wastewater § 63.110 Applicability. (a) This subpart applies to all process vents, storage vessels, transfer racks, wastewater streams, and in-process..., subpart III, NNN, or RRR, as applicable. (e) Overlap with other regulations for wastewater. (1) After the...
40 CFR 63.110 - Applicability.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Vents, Storage Vessels, Transfer Operations, and Wastewater § 63.110 Applicability. (a) This subpart applies to all process vents, storage vessels, transfer racks, wastewater streams, and in-process..., subpart III, NNN, or RRR, as applicable. (e) Overlap with other regulations for wastewater. (1) After the...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-19
... collected water into either a drain line or an in-unit container, these products do not use an exhaust port... conventional vented clothes dryer cannot be used, such as high-rise apartments and other buildings where... those dwellers of high-rise apartments and others who in many cases have no way to vent to the outside...
Low Gravity venting of Refrigerant 11
NASA Technical Reports Server (NTRS)
Labus, T. L.; Aydelott, J. C.; Lacovic, R. F.
1972-01-01
An experimental investigation was conducted in a five-second zero gravity facility to examine the effects of venting initially saturated Refrigerant 11 from a cylindrical container (15-cm diameter) under reduced gravitational conditions. The system Bond numbers studied were 0 (weightlessness), 9 and 63; the liquid exhibited a nearly zero-degree contact angle on the container surface. During the venting process, both liquid-vapor interface and liquid bulk vaporization occurred. The temperature of the liquid in the immediate vicinity of the liquid-vapor interface was found to decrease during venting, while the liquid bulk temperature remained constant. Qualitative observations of the effects of system acceleration, vent rate, and vapor volume presented. Quantitative information concerning the ullage pressure decay during low gravity venting is also included.
Code of Federal Regulations, 2014 CFR
2014-07-01
... or live steam. Closed-vent system means a system that is not open to the atmosphere and is composed... emissions from individual process vents, stacks, open pieces of process equipment, equipment leaks... stock chests, and their associated vacuum pumps, filtrate tanks, foam breakers or tanks, and any other...
Code of Federal Regulations, 2013 CFR
2013-07-01
... or live steam. Closed-vent system means a system that is not open to the atmosphere and is composed... emissions from individual process vents, stacks, open pieces of process equipment, equipment leaks... stock chests, and their associated vacuum pumps, filtrate tanks, foam breakers or tanks, and any other...
40 CFR 63.1326 - Batch process vents-recordkeeping provisions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutant Emissions: Group IV Polymers and Resins... requirements for Group 2 batch process vents that are exempt from the batch mass input limitation provisions...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Pollutants for Semiconductor Manufacturing Emission Standards § 63.7184 What emission limitations, operating... this section on and after the compliance dates specified in § 63.7183. (b) Process vents—organic HAP emissions. For each organic HAP process vent, other than process vents from storage tanks, you must limit...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Pollutants for Semiconductor Manufacturing Emission Standards § 63.7184 What emission limitations, operating... this section on and after the compliance dates specified in § 63.7183. (b) Process vents—organic HAP emissions. For each organic HAP process vent, other than process vents from storage tanks, you must limit...
Code of Federal Regulations, 2011 CFR
2011-07-01
... flash steam from the digester or live steam. Closed-vent system means a system that is not open to the... this subpart, including emissions from individual process vents, stacks, open pieces of process... stock chests, and their associated vacuum pumps, filtrate tanks, foam breakers or tanks, and any other...
Code of Federal Regulations, 2010 CFR
2010-07-01
... flash steam from the digester or live steam. Closed-vent system means a system that is not open to the... this subpart, including emissions from individual process vents, stacks, open pieces of process... stock chests, and their associated vacuum pumps, filtrate tanks, foam breakers or tanks, and any other...
Code of Federal Regulations, 2012 CFR
2012-07-01
... flash steam from the digester or live steam. Closed-vent system means a system that is not open to the... this subpart, including emissions from individual process vents, stacks, open pieces of process... stock chests, and their associated vacuum pumps, filtrate tanks, foam breakers or tanks, and any other...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 15 2010-07-01 2010-07-01 false Monitoring. 65.65 Section 65.65 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Process Vents § 65.65 Monitoring. (a) An owner or operator of a Group 2A process vent...
Preliminary geological mapping of Io
NASA Technical Reports Server (NTRS)
Masursky, H.; Schaber, G. G.; Soderblom, L. A.; Strom, R. G.
1979-01-01
A preliminary summary of information gained by Voyager 1 on the colored, terrain and landform surface units of Io and their global distribution is presented. Colored units are classified as white to bluish-white regions which may be sulfur or sulfur dioxide deposits, red, orange, or yellow regions thought to contain various sublimates or alterations of sulfur, brownish regions limited to the polar areas and dark brown areas surrounding some vents. Terrain features observed include plains broken by scarps, isolated mountainous regions and volcanic vents resembling terrestrial caldera or pit craters. Maps of the distribution of these features, compiled by photogeological mapping techniques developed for terrestrial volcanic mapping, are presented, and the implications of the surface unit distributions for the volcanology, crustal composition, internal convection patterns and surface age of Io are discussed.
40 CFR 65.140 - Applicability.
Code of Federal Regulations, 2010 CFR
2010-07-01
... FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas System or a Process § 65..., shutdown, and malfunction provisions in § 65.6) apply to routing emissions to processes, fuel gas systems, closed vent systems, control devices, and recovery devices where another subpart expressly references the...
40 CFR 63.1254 - Standards: Process vents.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) National Emission Standards for Pharmaceuticals Production § 63.1254 Standards: Process vents. (a) Existing... weight; and (3) The production-indexed HAP consumption factor for the 12-month period in which the..., as calibrated on methane or the predominant HAP, of 20 ppmv or less, and an outlet concentration of...
40 CFR 63.1254 - Standards: Process vents.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Standards for Pharmaceuticals Production § 63.1254 Standards: Process vents. (a) Existing sources. For each... weight; and (3) The production-indexed HAP consumption factor for the 12-month period in which the..., as calibrated on methane or the predominant HAP, of 20 ppmv or less, and an outlet concentration of...
40 CFR 63.1254 - Standards: Process vents.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) National Emission Standards for Pharmaceuticals Production § 63.1254 Standards: Process vents. (a) Existing... weight; and (3) The production-indexed HAP consumption factor for the 12-month period in which the..., as calibrated on methane or the predominant HAP, of 20 ppmv or less, and an outlet concentration of...
40 CFR 63.1254 - Standards: Process vents.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Standards for Pharmaceuticals Production § 63.1254 Standards: Process vents. (a) Existing sources. For each... weight; and (3) The production-indexed HAP consumption factor for the 12-month period in which the..., as calibrated on methane or the predominant HAP, of 20 ppmv or less, and an outlet concentration of...
40 CFR 63.1254 - Standards: Process vents.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Standards for Pharmaceuticals Production § 63.1254 Standards: Process vents. (a) Existing sources. For each... weight; and (3) The production-indexed HAP consumption factor for the 12-month period in which the..., as calibrated on methane or the predominant HAP, of 20 ppmv or less, and an outlet concentration of...
Code of Federal Regulations, 2010 CFR
2010-07-01
... total organic compounds (TOC) (minus methane and ethane) to a level below 1.4 kg/hr and 2.8 Mg/yr (3.0... process vents the emissions of TOC (minus methane and ethane) by 95 percent by weight or more. (c) For...
40 CFR 63.645 - Test methods and procedures for miscellaneous process vents.
Code of Federal Regulations, 2014 CFR
2014-07-01
... applicable to the process vent. (iv) Design analysis based on accepted chemical engineering principles..., dry standard cubic meters per minute, at a temperature of 20 °C. (g) Engineering assessment may be... the highest daily emission rate. (1) Engineering assessment includes, but is not limited to, the...
40 CFR 63.7892 - What are my inspection and monitoring requirements for process vents?
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 14 2014-07-01 2014-07-01 false What are my inspection and monitoring requirements for process vents? 63.7892 Section 63.7892 Protection of Environment ENVIRONMENTAL PROTECTION... SOURCE CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants: Site Remediation...
40 CFR 63.7892 - What are my inspection and monitoring requirements for process vents?
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 13 2011-07-01 2011-07-01 false What are my inspection and monitoring requirements for process vents? 63.7892 Section 63.7892 Protection of Environment ENVIRONMENTAL PROTECTION... SOURCE CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants: Site Remediation...
40 CFR 63.7892 - What are my inspection and monitoring requirements for process vents?
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 14 2012-07-01 2011-07-01 true What are my inspection and monitoring requirements for process vents? 63.7892 Section 63.7892 Protection of Environment ENVIRONMENTAL PROTECTION... SOURCE CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants: Site Remediation...
40 CFR 63.7892 - What are my inspection and monitoring requirements for process vents?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 13 2010-07-01 2010-07-01 false What are my inspection and monitoring requirements for process vents? 63.7892 Section 63.7892 Protection of Environment ENVIRONMENTAL PROTECTION... SOURCE CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants: Site Remediation...
40 CFR 63.7937 - How do I demonstrate initial compliance with the general standards?
Code of Federal Regulations, 2012 CFR
2012-07-01
... with the general standards? 63.7937 Section 63.7937 Protection of Environment ENVIRONMENTAL PROTECTION... SOURCE CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants: Site Remediation... remediation material treated or managed by the process vented through the affected process vents has an...
40 CFR 63.7892 - What are my inspection and monitoring requirements for process vents?
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 14 2013-07-01 2013-07-01 false What are my inspection and monitoring requirements for process vents? 63.7892 Section 63.7892 Protection of Environment ENVIRONMENTAL PROTECTION... SOURCE CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants: Site Remediation...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Hazardous Air Pollutant Emissions for Polyether Polyols Production § 63.1428 Process vent requirements for... make or modify a polyether polyol for a PMPU are less than 11,800 kg/yr, the owner or operator of that...
40 CFR 63.1425 - Process vent control requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Standards for Hazardous Air Pollutant Emissions for Polyether Polyols Production § 63.1425 Process vent... operators of all affected sources using epoxides in the production of polyether polyols are subject to the... (c) of this section only if epoxides are used in the production of polyether polyols and nonepoxide...
40 CFR 63.2460 - What requirements must I meet for batch process vents?
Code of Federal Regulations, 2010 CFR
2010-07-01
.... (ii) When you conduct a performance test or design evaluation for a non-flare control device used to... paragraphs (c)(9)(ii)(A) through (D) of this section. The design evaluation option for small control devices...) of this section. (b) Group status. If a process has batch process vents, as defined in § 63.2550, you...
40 CFR 63.2460 - What requirements must I meet for batch process vents?
Code of Federal Regulations, 2011 CFR
2011-07-01
.... (ii) When you conduct a performance test or design evaluation for a non-flare control device used to... paragraphs (c)(9)(ii)(A) through (D) of this section. The design evaluation option for small control devices...) of this section. (b) Group status. If a process has batch process vents, as defined in § 63.2550, you...
40 CFR 63.2460 - What requirements must I meet for batch process vents?
Code of Federal Regulations, 2014 CFR
2014-07-01
.... (ii) When you conduct a performance test or design evaluation for a non-flare control device used to... paragraphs (c)(9)(ii)(A) through (D) of this section. The design evaluation option for small control devices... (c) of this section. (b) Group status. If a process has batch process vents, as defined in § 63.2550...
40 CFR 63.2460 - What requirements must I meet for batch process vents?
Code of Federal Regulations, 2012 CFR
2012-07-01
.... (ii) When you conduct a performance test or design evaluation for a non-flare control device used to... paragraphs (c)(9)(ii)(A) through (D) of this section. The design evaluation option for small control devices... (c) of this section. (b) Group status. If a process has batch process vents, as defined in § 63.2550...
40 CFR 63.2460 - What requirements must I meet for batch process vents?
Code of Federal Regulations, 2013 CFR
2013-07-01
.... (ii) When you conduct a performance test or design evaluation for a non-flare control device used to... paragraphs (c)(9)(ii)(A) through (D) of this section. The design evaluation option for small control devices... (c) of this section. (b) Group status. If a process has batch process vents, as defined in § 63.2550...
Schwantes, Jon M; Orton, Christopher R; Clark, Richard A
2012-08-21
Researchers evaluated radionuclide measurements of environmental samples taken from the Fukushima Daiichi nuclear facility and reported on the Tokyo Electric Power Co. Website following the 2011 tsunami-initiated catastrophe. This effort identified Units 1 and 3 as the major source of radioactive contamination to the surface soil near the facility. Radionuclide trends identified in the soils suggested that: (1) chemical volatility driven by temperature and reduction potential within the vented reactors' primary containment vessels dictated the extent of release of radiation; (2) all coolant had likely evaporated by the time of venting; and (3) physical migration through the fuel matrix and across the cladding wall were minimally effective at containing volatile species, suggesting damage to fuel bundles was extensive. Plutonium isotopic ratios and their distance from the source indicated that the damaged reactors were the major contributor of plutonium to surface soil at the source, decreasing rapidly with distance from the facility. Two independent evaluations estimated the fraction of the total plutonium inventory released to the environment relative to cesium from venting Units 1 and 3 to be ∼0.002-0.004%. This study suggests significant volatile radionuclides within the spent fuel at the time of venting, but not as yet observed and reported within environmental samples, as potential analytes of concern for future environmental surveys around the site. The majority of the reactor inventories of isotopes of less volatile elements like Pu, Nb, and Sr were likely contained within the damaged reactors during venting.
Spatial and Alignment Analyses for a field of Small Volcanic Vents South of Pavonis Mons Mars
NASA Technical Reports Server (NTRS)
Bleacher, J. E.; Glaze, L. S.; Greeley, R.; Hauber, E.; Baloga, S. M.; Sakimoto, S. E. H.; Williams, D. A.; Glotch, T. D.
2008-01-01
The Tharsis province of Mars displays a variety of small volcanic vent (10s krn in diameter) morphologies. These features were identified in Mariner and Viking images [1-4], and Mars Orbiter Laser Altimeter (MOLA) data show them to be more abundant than originally observed [5,6]. Recent studies are classifying their diverse morphologies [7-9]. Building on this work, we are mapping the location of small volcanic vents (small-vents) in the Tharsis province using MOLA, Thermal Emission Imaging System, and High Resolution Stereo Camera data [10]. Here we report on a preliminary study of the spatial and alignment relationships between small-vents south of Pavonis Mons, as determined by nearest neighbor and two-point azimuth statistical analyses. Terrestrial monogenetic volcanic fields display four fundamental characteristics: 1) recurrence rates of eruptions,2 ) vent abundance, 3) vent distribution, and 4) tectonic relationships [11]. While understanding recurrence rates typically requires field measurements, insight into vent abundance, distribution, and tectonic relationships can be established by mapping of remotely sensed data, and subsequent application of spatial statistical studies [11,12], the goal of which is to link the distribution of vents to causal processes.
NASA Technical Reports Server (NTRS)
1978-01-01
Another spinoff from spacecraft fuel cell technology is the portable hydrogen generator shown. Developed by General Electric Company, it is an aid to safer operation of systems that use hydrogen-for example, gas chromatographs, used in laboratory analysis of gases. or flame ionization detectors used as $ollution monitors. The generator eliminates the need for high-pressure hydrogen storage bottles, which can be a safety hazard, in laboratories, hospitals and industrial plants. The unit supplies high-purity hydrogen by means of an electrochemical process which separates the hydrogen and oxygen in distilled water. The oxygen is vented away and the hydrogen gas is stored within the unit for use as needed. GE's Aircraft Equipment Division is producing about 1,000 of the generators annually.
Management of turbidity current venting in reservoirs under different bed slopes.
Chamoun, Sabine; De Cesare, Giovanni; Schleiss, Anton J
2017-12-15
The lifetime and efficiency of dams is endangered by the process of sedimentation. To ensure the sustainable use of reservoirs, many sediment management techniques exist, among which venting of turbidity currents. Nevertheless, a number of practical questions remain unanswered due to a lack of systematic investigations. The present research introduces venting and evaluates its performance using an experimental model. In the latter, turbidity currents travel on a smooth bed towards the dam and venting is applied through a rectangular bottom outlet. The combined effect of outflow discharge and bed slopes on the sediment release efficiency of venting is studied based on different criteria. Several outflow discharges are tested using three different bed slopes (i.e., 0%, 2.4% and 5.0%). Steeper slopes yield higher venting efficiency. Additionally, the optimal outflow discharge leading to the largest venting efficiency with the lowest water loss increases when moving from the horizontal bed to the inclined positions. Copyright © 2017 Elsevier Ltd. All rights reserved.
22. STEEL ARCH SEGMENT AND VENT IN OFFICE, ROOM 2351, ...
22. STEEL ARCH SEGMENT AND VENT IN OFFICE, ROOM 2351, SECOND FLOOR, NORTH SIDE. - Hughes Aircraft Company, Processing & Electronics Building, 6775 Centinela Avenue, Los Angeles, Los Angeles County, CA
Code of Federal Regulations, 2011 CFR
2011-07-01
... National Emission Standards for Hazardous Air Pollutant Emissions for Polyether Polyols Production § 63... percent reduction may be measured as total epoxide, total organic HAP, or as TOC minus methane and ethane... TOC (minus methane and ethane) concentrations in all process vent streams and primary and secondary...
Code of Federal Regulations, 2012 CFR
2012-07-01
... National Emission Standards for Hazardous Air Pollutant Emissions for Polyether Polyols Production § 63... percent reduction may be measured as total epoxide, total organic HAP, or as TOC minus methane and ethane... TOC (minus methane and ethane) concentrations in all process vent streams and primary and secondary...
40 CFR 63.1103 - Source category-specific applicability, definitions, and requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... separation of raw materials and by-products from the stabilized polymer. Front end process vent means any... vent systems, control devices, recovery devices, and routing to a fuel gas system or a process), as... allow worker access; passage of material into or out of the enclosure by conveyor, vehicles, or other...
40 CFR 63.7937 - How do I demonstrate initial compliance with the general standards?
Code of Federal Regulations, 2014 CFR
2014-07-01
... compliance with the general standards? 63.7937 Section 63.7937 Protection of Environment ENVIRONMENTAL... Remediation General Compliance Requirements § 63.7937 How do I demonstrate initial compliance with the general... remediation material treated or managed by the process vented through the affected process vents has an...
40 CFR 63.7937 - How do I demonstrate initial compliance with the general standards?
Code of Federal Regulations, 2011 CFR
2011-07-01
... compliance with the general standards? 63.7937 Section 63.7937 Protection of Environment ENVIRONMENTAL... Remediation General Compliance Requirements § 63.7937 How do I demonstrate initial compliance with the general... remediation material treated or managed by the process vented through the affected process vents has an...
40 CFR 63.7937 - How do I demonstrate initial compliance with the general standards?
Code of Federal Regulations, 2013 CFR
2013-07-01
... compliance with the general standards? 63.7937 Section 63.7937 Protection of Environment ENVIRONMENTAL... Remediation General Compliance Requirements § 63.7937 How do I demonstrate initial compliance with the general... remediation material treated or managed by the process vented through the affected process vents has an...
40 CFR 63.7937 - How do I demonstrate initial compliance with the general standards?
Code of Federal Regulations, 2010 CFR
2010-07-01
... Remediation General Compliance Requirements § 63.7937 How do I demonstrate initial compliance with the general... remediation material treated or managed by the process vented through the affected process vents has an..., according to the procedures § 63.7943, and recorded the average VOHAP concentration of the remediation...
Coupled fluid and solid evolution in analogue volcanic vents
NASA Astrophysics Data System (ADS)
Solovitz, Stephen A.; Ogden, Darcy E.; Kim, Dave (Dae-Wook); Kim, Sang Young
2014-07-01
Volcanic eruptions emit rock particulates and gases at high speed and pressure, which change the shape of the surrounding rock. Simplified analytical solutions, field studies, and numerical models suggest that this process plays an important role in the behavior and hazards associated with explosive volcanic eruptions. Here we present results from a newly developed laboratory-scale apparatus designed to study this coupled process. The experiments used compressed air jets expanding into the laboratory through fabricated rock analogue material, which evolves through time during the experiment. The compressed air was injected at approximately 2.5 times atmospheric pressure. We fabricated rock analogues from sand and steel powder samples with a three-dimensional printing process. We studied the fluid development using phase-locked particle image velocimetry, while simultaneously observing the solid development via a video camera. We found that the fluid response was much more rapid than that of the solid, permitting a quasi-steady approximation. In most cases, the solid vent flared out rapidly, increasing its diameter by 20 to 100%. After the initial expansion, the vent and flow field achieved a near-steady condition for a long duration. The new expanded vent shapes permitted lower vent exit pressures and larger jet radii. In one experiment, after an initial vent shape development and establishment of steady flow behavior, rock failure occurred a second time, resulting in a new exit diameter and new steady state. This second failure was not precipitated by changes in the nozzle flow condition, and it radically changed the downstream flow dynamics. This experiment suggests that the brittle nature of volcanic host rock enables sudden vent expansion in the middle of an eruption without requiring a change in the conduit flow.
Code of Federal Regulations, 2010 CFR
2010-07-01
... vent; Ei, Eo = Mass rate of total organic compounds (TOC) (minus methane and ethane) or total HAP, from... reduction for all affected process vents, percent Ei = Mass rate of TOC (minus methane and ethane) or total... uncontrolled vents, as calculated in this section, kilograms TOC per hour or kilograms HAP per hour; Eo = Mass...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Closed vent systems and control... this part, except as provided in § 63.1002(b). (2) Owners or operators of closed vent systems and... in subpart SS of this part, except as provided in § 63.1002(b). (3) Owners or operators routing...
Code of Federal Regulations, 2011 CFR
2011-07-01
... epoxides, and that are using ECO as a control technique to reduce epoxide emissions in order to comply with... provisions of this section. The owner or operator that is using ECO in order to comply with the emission... used to further reduce the HAP emissions from a process vent already controlled by ECO, then the owner...
Evidence for extensive methane venting on the southeastern U.S. Atlantic margin
Brothers, L.L.; Van Dover, C.L.; German, C.R.; Kaiser, C.L.; Yoerger, D.R.; Ruppel, C.D.; Lobecker, E.; Skarke, A.D.; Wagner, J.K.S.
2013-01-01
We present the first evidence for widespread seabed methane venting along the southeastern United States Atlantic margin beyond the well-known Blake Ridge diapir seep. Recent ship- and autonomous underwater vehicle (AUV)–collected data resolve multiple water-column anomalies (>1000 m height) and extensive new chemosynthetic seep communities at the Blake Ridge and Cape Fear diapirs. These results indicate that multiple, highly localized fluid conduits punctuate the areally extensive Blake Ridge gas hydrate province, and enable the delivery of significant amounts of methane to the water column. Thus, there appears to be an abundance of seabed fluid flux not previously ascribed to the Atlantic margin of the United States.
Fissure near Cerberus Fossae with Tectonic Morphologies
2014-01-15
The linearity of the volcanic vent shown in this image observed by NASA Mars Reconnaissance Orbiter, in conjunction with evidence of lava flow from the vent, suggests control by combined volcano-tectonic processes.
NASA Technical Reports Server (NTRS)
Knox, James C.; Campbell, Melissa; Murdoch, Karen; Miller, Lee A.; Jeng, Frank
2005-01-01
Currently on the International Space Station s (ISS) U.S. Segment, carbon dioxide (CO2) scrubbed from the cabin by a 4-Bed Molecular Sieve (4BMS) Carbon Dioxide Removal Assembly (CDRA) is vented overboard as a waste product. Likewise, the product hydrogen (H2) that will be generated by the Oxygen Generation Assembly (OGA) planned for installation will also be vented. A flight experiment has been proposed that will take the waste CO2 removed from the cabin, and via the catalytic Sabatier process, reduce it with waste H2 to generate water and methane. The water produced may provide cost and logistics savings for ISS by reducing the amount of water periodically re-supplied to orbit. To make this concept viable, a mechanical piston compressor and accumulator were developed for collecting and storing the CO2 from the CDRA. The compressor, accumulator and Sabatier system would be packaged together as one unit and referred to as the Carbon Dioxide Reduction Assembly (CRA). Testing was required to evaluate the performance of a 4BMS CDRA, compressor, accumulator, and Sabatier performance along with their operating rules when integrated together. This had been numerically modeled and simulated; however, testing was necessary to verify the results from the engineering analyses. Testing also allowed a better understanding of the practical inefficiencies and control issues involved in a fully integrated system versus the theoretical ideals in the model. This paper presents and discusses the results of an integrated engineering development unit test.
NASA Astrophysics Data System (ADS)
Tsuji, T.; Nishizaka, N.; Onishi, K.
2017-12-01
Sedimentation processes during explosive volcanic eruptions can be constrained based on detailed analysis of grain-size variation of tephra deposits. Especially, an accurate description of the amount of fine particles has also significant implications for the assessment of specific tephra hazards. Grain size studies for single short-term eruption has advantage to contribute understanding the sedimentation processes because it is simple compared to long-lasting eruption. The 2016 Aso Nakadake eruption, Japan represents an ideal for the study of short-term eruptions thanks to an accurate investigation. Then, we investigate the grain size variation with distance from the vent and sedimentological features of the deposit to discuss the sedimentation processes of the tephra fragments. The eruption provided pyroclastic flow deposit and fallout tephra which distributed NE to ENE direction from the vent. The deposits between 4 and 20 km from vent consist of fine-coated lapilli to coarse ash, ash pellet and mud droplet in ascending degree. The samples are lapilli-bearing within 20 km from vent and those outside of 20 km mainly consist of ash particles. Detailed analyses of individual samples highlight a rapid decay of maximum and mean grain size for the deposit from proximal to distal. The decay trend of maximum grain-size is approximated by three segments of exponential curves with two breaks-in-slope at 10 and 40 km from vent. Most of the sampled deposits are characterized by bimodal grain-size distributions, with the modes of the coarse subpopulation decreasing with distance from vent and those of the fine subpopulation being mostly stable. The fine subpopulation has been interpreted as being mostly associated with size-selective sedimentation processes (e.g., particle aggregation) confirmed by the existence of fine-coated particles, ash pellet and mud droplet. As the fine-coated particles generally have a higher terminal velocity than the individual constituent particles, those could be related with the rapid decrease of maximum grain-size with distance from vent at proximal area. Further detail grain-size analyses and theoretical studies can be contributed to understand the effect of fine ash aggregation on sedimentation processes quantitatively.
40 CFR 65.167 - Other reports.
Code of Federal Regulations, 2010 CFR
2010-07-01
... FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas System or a Process § 65... reporting and shall include a description of any changes made to the closed vent system. (b) Startup...
40 CFR 63.7188 - What are my monitoring installation, operation, and maintenance requirements?
Code of Federal Regulations, 2011 CFR
2011-07-01
... Semiconductor Manufacturing Compliance Requirements § 63.7188 What are my monitoring installation, operation... emissions of your semiconductor process vent through a closed vent system to a control device, you must...
40 CFR 63.7188 - What are my monitoring installation, operation, and maintenance requirements?
Code of Federal Regulations, 2010 CFR
2010-07-01
... Semiconductor Manufacturing Compliance Requirements § 63.7188 What are my monitoring installation, operation... emissions of your semiconductor process vent through a closed vent system to a control device, you must...
Fluid Flow and Sound Generation at Hydrothermal Vent Fields
1988-04-01
Pacific Rise The first evidence of vent sound generation came from data collected near hydrothermal vents at 21 N on the EPR where an array of ocean...associated with hydrothermal centers, one at 21 N on the East Pacific Rise (EPR) (Reidesel et al., 1982) and one on the Juan de Fuca Ridge (Bibee and Jacobson... East Pacific Rise at 210 N : the volcanic, tectonic and hydrothermal processes at
Thermodynamic modeling of the no-vent fill methodology for transferring cryogens in low gravity
NASA Technical Reports Server (NTRS)
Chato, David J.
1988-01-01
The filling of tanks with cryogens in the low-gravity environment of space poses many technical challenges. Chief among these is the inability to vent only vapor from the tank as the filling proceeds. As a potential solution to this problem, the NASA Lewis Research Center is researching a technique known as No-Vent Fill. This technology potentially has broad application. The focus is the fueling of space based Orbital Transfer Vehicles. The fundamental thermodynamics of the No-Vent Fill process to develop an analytical model of No-Vent Fill is described. The model is then used to conduct a parametric investigation of the key parameters: initial tank wall temperature, liquid-vapor interface heat transfer rate, liquid inflow rate, and inflowing liquid temperatures. Liquid inflowing temperature and the liquid-vapor interface heat transfer rate seem to be the most significant since they influence the entire fill process. The initial tank wall temperature must be sufficiently low to prevent a rapid pressure rise during the initial liquid flashing stage, but then becomes less significant.
Code of Federal Regulations, 2012 CFR
2012-07-01
... consistent with the manufacturer's recommendations within 15 days or by the next time any process vent stream... the manufacturer's recommendations within 15 days or by the next time any process vent stream is...) Determine gas stream flow using the design blower capacity, with appropriate adjustments for pressure drop...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Pollutants: Miscellaneous Organic Chemical Manufacturing Pt. 63, Subpt. FFFF, Table 2 Table 2 to Subpart FFFF... Group 1 batch process vents a. Reduce collective uncontrolled organic HAP emissions from the sum of all... a flare); or Not applicable. b. Reduce collective uncontrolled organic HAP emissions from the sum of...
40 CFR 63.136 - Process wastewater provisions-individual drain systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
... requirements of § 63.148 and the control device shall be designed, operated, and inspected in accordance with... that receives or manages a Group 1 wastewater stream or a residual removed from a Group 1 wastewater... cover and if vented, route the vapors to a process or through a closed vent system to a control device...
Code of Federal Regulations, 2012 CFR
2012-07-01
... and recordkeeping requirements for group and TRE determinations and performance tests. (a) Each owner or operator subject to the control provisions for Group 1 process vents in § 63.113(a) or the... recordkeeping requirements for group and TRE determinations and performance tests. 63.117 Section 63.117...
40 CFR 63.136 - Process wastewater provisions-individual drain systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
... requirements of § 63.148 and the control device shall be designed, operated, and inspected in accordance with... that receives or manages a Group 1 wastewater stream or a residual removed from a Group 1 wastewater... cover and if vented, route the vapors to a process or through a closed vent system to a control device...
40 CFR 63.136 - Process wastewater provisions-individual drain systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
... requirements of § 63.148 and the control device shall be designed, operated, and inspected in accordance with... that receives or manages a Group 1 wastewater stream or a residual removed from a Group 1 wastewater... cover and if vented, route the vapors to a process or through a closed vent system to a control device...
40 CFR 63.136 - Process wastewater provisions-individual drain systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
... requirements of § 63.148 and the control device shall be designed, operated, and inspected in accordance with... that receives or manages a Group 1 wastewater stream or a residual removed from a Group 1 wastewater... cover and if vented, route the vapors to a process or through a closed vent system to a control device...
Code of Federal Regulations, 2014 CFR
2014-07-01
... and recordkeeping requirements for group and TRE determinations and performance tests. (a) Each owner or operator subject to the control provisions for Group 1 process vents in § 63.113(a) or the... recordkeeping requirements for group and TRE determinations and performance tests. 63.117 Section 63.117...
Flotation process for removal of precipitates from electrochemical chromate reduction unit
DeMonbrun, James R.; Schmitt, Charles R.; Williams, Everett H.
1976-01-01
This invention is an improved form of a conventional electrochemical process for removing hexavalent chromium or other metal-ion contaminants from cooling-tower blowdown water. In the conventional process, the contaminant is reduced and precipitated at an iron anode, thus forming a mixed precipitate of iron and chromium hydroxides, while hydrogen being evolved copiously at a cathode is vented from the electrochemical cell. In the conventional process, subsequent separation of the fine precipitate has proved to be difficult and inefficient. In accordance with this invention, the electrochemical operation is conducted in a novel manner permitting a much more efficient and less expensive precipitate-recovery operation. That is, the electrochemical operation is conducted under an evolved-hydrogen partial pressure exceeding atmospheric pressure. As a result, most of the evolved hydrogen is entrained as bubbles in the blowdown in the cell. The resulting hydrogen-rich blowdown is introduced to a vented chamber, where the entrained hydrogen combines with the precipitate to form a froth which can be separated by conventional techniques. In addition to the hydrogen, two materials present in most blowdown act as flotation promoters for the precipitate. These are (1) air, with which the blowdown water becomes saturated in the course of normal cooling-tower operation, and (2) surfactants which commonly are added to cooling-tower recirculating-water systems to inhibit the growth of certain organisms or prevent the deposition of insoluble particulates.
Study of cryogenic propellant systems for loading the space shuttle. Part 2: Hydrogen systems
NASA Technical Reports Server (NTRS)
Steward, W. G.
1975-01-01
Computer simulation studies of liquid hydrogen fill and vent systems for the space shuttle are studied. The computer programs calculate maximum and minimum permissible flow rates during cooldown as limited by thermal stress considerations, fill line cooldown time, pressure drop, flow rates, vapor content, vent line pressure drop and vent line discharge temperature. The input data for these programs are selected through graphic displays which schematically depict the part of the system being analyzed. The computed output is also displayed in the form of printed messages and graphs. Digital readouts of graph coordinates may also be obtained. Procedures are given for operation of the graphic display unit and the associated minicomputer and timesharing computer.
40 CFR 65.67 - Reporting provisions.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., organic HAP or TOC concentration, and/or TRE index value required under § 65.63(f) and recorded under § 65... 2B process vent, the organic HAP or TOC concentration of the vent stream is recalculated according to...
Modeling of zero gravity venting: Studies of two-phase heat transfer under reduced gravity
NASA Technical Reports Server (NTRS)
Merte, H., Jr.
1986-01-01
The objective is to predict the pressure response of a saturated liquid-vapor system when undergoing a venting or depressurization process in zero gravity at low vent rates. An experimental investigation of the venting of cylindrical containers partially filled with initially saturated liquids was previously conducted under zero-gravity conditions and compared with an analytical model which incorporated the effect of interfacial mass transfer on the ullage pressure response during venting. A new model is presented to improve the estimation of the interfacial mass transfer. Duhammel's superposition integral is incorporated to approximate the transient temperature response of the interface, treating the liquid as a semi-infinite solid with conduction heat transfer. Account is also taken of the condensation taking place within the bulk of a saturated vapor as isentropic expansion takes place. Computational results are presented for the venting of R-11 from a given vessel and initial state for five different venting rates over a period of three seconds, and compared to prior NASA experiments. An improvement in the prediction of the final pressure takes place, but is still considerably below the measurements.
Code of Federal Regulations, 2012 CFR
2012-01-01
... venting, external cooling by an ancillary system, or operational controls during transport. Natural...: The International System of Units (SI) followed or preceded by U.S. standard or customary units. The U... water as a common, contract, or private carrier, or by civil aircraft. Certificate holder means a person...
Code of Federal Regulations, 2011 CFR
2011-01-01
... venting, external cooling by an ancillary system, or operational controls during transport. Natural...: The International System of Units (SI) followed or preceded by U.S. standard or customary units. The U... water as a common, contract, or private carrier, or by civil aircraft. Certificate holder means a person...
Code of Federal Regulations, 2010 CFR
2010-01-01
... venting, external cooling by an ancillary system, or operational controls during transport. Natural...: The International System of Units (SI) followed or preceded by U.S. standard or customary units. The U... water as a common, contract, or private carrier, or by civil aircraft. Certificate holder means a person...
40 CFR 265.1035 - Recordkeeping requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... waste management units in one recordkeeping system if the system identifies each record by each... data supporting determinations of vent emissions and emission reductions achieved by add-on control... that result in maximum organic emissions, such as when the waste management unit is operating at the...
40 CFR 264.1064 - Recordkeeping requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... management units in one recordkeeping system if the system identifies each record by each hazardous waste management unit. (b) Owners and operators must record the following information in the facility operating... monitoring, operating, and inspection information for each closed-vent system and control device required to...
NASA Astrophysics Data System (ADS)
Poland, Michael P.; Carbone, Daniele
2016-07-01
Continuous gravity data collected near the summit eruptive vent at Kīlauea Volcano, Hawaíi, during 2011-2015 show a strong correlation with summit-area surface deformation and the level of the lava lake within the vent over periods of days to weeks, suggesting that changes in gravity reflect variations in volcanic activity. Joint analysis of gravity and lava level time series data indicates that over the entire time period studied, the average density of the lava within the upper tens to hundreds of meters of the summit eruptive vent remained low—approximately 1000-1500 kg/m3. The ratio of gravity change (adjusted for Earth tides and instrumental drift) to lava level change measured over 15 day windows rose gradually over the course of 2011-2015, probably reflecting either (1) a small increase in the density of lava within the eruptive vent or (2) an increase in the volume of lava within the vent due to gradual vent enlargement. Superimposed on the overall time series were transient spikes of mass change associated with inflation and deflation of Kīlauea's summit and coincident changes in lava level. The unexpectedly strong mass variations during these episodes suggest magma flux to and from the shallow magmatic system without commensurate deformation, perhaps indicating magma accumulation within, and withdrawal from, void space—a process that might not otherwise be apparent from lava level and deformation data alone. Continuous gravity data thus provide unique insights into magmatic processes, arguing for continued application of the method at other frequently active volcanoes.
Determination of the Hydraulic Conductivity of the Alachua County Southwest Landfill
1993-05-01
vents were in the 30-acre unit. Leachate Level Measurements The leachate levels in theias vents were monitored on a monthly basis with- an electric tape ...Occasionally the electric tape gave false or intermittent readings as a result of the condensate which accumulated on the sidewalls of the 58 59 gas...confirm the results. Later in the study, a weighted stainless steel tape was also used to measure the depth of the leachate. The combination of the
40 CFR 65.155 - Other control devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) CONSOLIDATED FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas System or a Process § 65.155 Other control devices. (a) Other control device equipment and operating requirements. (1... requirements specified in § 65.63(a)(2), or 40 CFR 60.562-1(a)(1)(i)(A) for process vents, or § 65.83(a)(1) for...
Code of Federal Regulations, 2010 CFR
2010-07-01
... percent reduction may be measured as total epoxide, total organic HAP, or as TOC minus methane and ethane... TOC (minus methane and ethane) concentrations in all process vent streams and primary and secondary... million by volume total epoxide or TOC limit in § 63.1425(b)(1)(ii) or (b)(2)(iii), the sampling site...
40 CFR 63.645 - Test methods and procedures for miscellaneous process vents.
Code of Federal Regulations, 2010 CFR
2010-07-01
... TOC emission rate, as specified under paragraph (f) of this section, the sampling site shall be after... process vent TOC mass flow rate is less than 33 kilograms per day for an existing source or less than 6.8... shall determine the TOC mass flow rate by the following procedures: (1) The sampling site shall be...
40 CFR 63.2480 - What requirements must I meet for equipment leaks?
Code of Federal Regulations, 2011 CFR
2011-07-01
... affected source. (5) For pumps in light liquid service in an MCPU that has no continuous process vents and.../vapor and light liquid service at an existing source, you may elect to comply with the requirements in... light liquid service in an MCPU that has no continuous process vents and is part of an existing source...
NASA Astrophysics Data System (ADS)
Tournigand, Pierre-Yves; Taddeucci, Jacopo; José Peña Fernandez, Juan; Gaudin, Damien; Sesterhenn, Jörn; Scarlato, Piergiorgio; Del Bello, Elisabetta
2016-04-01
Vent conditions are key parameters controlling volcanic plume dynamics and the ensuing different hazards, such as human health issues, infrastructure damages, and air traffic disruption. Indeed, for a given magma and vent geometry, plume development and stability over time mainly depend on the mass eruption rate, function of the velocity and density of the eruptive mixture at the vent, where direct measurements are impossible. High-speed imaging of eruptive plumes and numerical jet simulations were here non-dimensionally coupled to retrieve eruptive vent conditions starting from measurable plume parameters. High-speed videos of unsteady, momentum-driven volcanic plumes (jets) from Strombolian to Vulcanian activity from three different volcanoes (Sakurajima, Japan, Stromboli, Italy, and Fuego, Guatemala) were recorded in the visible and the thermal spectral ranges by using an Optronis CR600x2 (1280x1024 pixels definition, 500 Hz frame rate) and a FLIR SC655 (640x480 pixels definition, 50 Hz frame rate) cameras. Atmospheric effects correction and pre-processing of the thermal videos were performed to increase measurement accuracy. Pre-processing consists of the extraction of the plume temperature gradient over time, combined with a temperature threshold in order to remove the image background. The velocity and the apparent surface temperature fields of the plumes, and their changes over timescales of tenths of seconds, were then measured by particle image velocimetry and thermal image analysis, respectively, of the pre-processed videos. The parameters thus obtained are representative of the outer plume surface, corresponding to its boundary shear layer at the interface with the atmosphere, and may significantly differ from conditions in the plume interior. To retrieve information on the interior of the plume, and possibly extrapolate it even at the eruptive vent level, video-derived plume parameters were non-dimensionally compared to the results of numerical simulations of momentum-driven gas jets impulsively released from a vent in a pressurized container. These simulations solve flow conditions globally, thus allowing one to set empirical relations between flow conditions in different parts of the jet, most notably the shear layer, the flow centerline, and at the vent. Applying these relations to the volcanic cases gives access to the evolution of velocity and temperature at the vent. From these, the speed of sound and flow Mach number can be obtained, which in turn can be used to estimate the pressure ratio between atmosphere and vent and finally, assuming some conduit geometry and mixture density, the total amount of erupted gas. Preliminary results suggest subsonic exit velocities of the eruptive mixture at the vent, and a plume centerline velocity that can be twice as fast as the one measured at the plume boundary.
Explosive volcanism on Mercury: Analysis of vent and deposit morphology and modes of eruption
NASA Astrophysics Data System (ADS)
Jozwiak, Lauren M.; Head, James W.; Wilson, Lionel
2018-03-01
The MESSENGER mission revealed, for the first time, conclusive evidence of explosive volcanism on Mercury. Several previous works have cataloged the appearance and location of explosive volcanism on the planet using a variety of identifying characteristics, including vent presence and deposit color as seen in multispectral image mosaics. We present here a comprehensive catalog of vents of likely volcanic origin; our classification scheme emphasizes vent morphology. We have analyzed the morphologies of all vents in our catalog, and recognize three main morphologies: "simple vent", "pit vent", and "vent-with-mound". The majority of vents we identify are located within impact craters. The spatial distribution of vents does not correlate with the locations of volcanic smooth plains deposits, in contrast to the Moon, nor do vents correlate with the locations of large impact basins (except for the Caloris and Tolstoj basins). Using the degradation state of the vent host crater as a proxy for maximum age, we suggest that vent formation has been active through the Mansurian and into the Kuiperian periods, although the majority of vents were likely formed much earlier in mercurian history. The morphologies and locations of vents are used to investigate a set of plausible formation geometries. We find that the most likely and most prevalent formation geometry is that of a dike, stalled at depth, which then explosively vents to the surface. We compare the vent and deposit size of mercurian pyroclastic deposits with localized and regional lunar pyroclastic deposits, and find a range of possible eruption energies and corresponding variations in eruption style. Localized lunar pyroclastic deposits and the majority of mercurian pyroclastic deposits show evidence for eruption that is consistent with the magmatic foam at the top of a dike reaching a critical gas volume fraction. A subset of mercurian vents, including the prominent Copland-Rachmaninoff vent to the northeast of the Rachmaninoff basin, indicates eruption at enhanced gas volume fractions. This subset of vents shows a similar eruptive behavior to the lunar Orientale dark mantle ring deposit, suggesting that the dikes that formed these vents and deposits on Mercury underwent some form of additional volatile build-up either through crustal volatile incorporation or magma convection within the dike. There also exists a population of mercurian vents that no longer retain a visible associated pyroclastic deposit; we hypothesize that the visible signature of the pyroclastic deposit has been lost through space weathering and regolith mixing processes. Together, these results provide a comprehensive analysis of explosive volcanism on Mercury, and inform continued research on the thermal history of Mercury and magma composition and evolution.
Repeat terrestrial lidar mapping of the new volcanic vent at Holuhraun, Iceland
NASA Astrophysics Data System (ADS)
Richardson, J. A.; Whelley, P.; Sutton, S.; Needham, D. H.; Byrne, S.; Hamilton, C.
2016-12-01
The locations and morphologies of volcanic vents are essential observations that inform models of volcanic processes on Earth and other planets. Post-eruption morphologic changes at vents are important to characterize in order to more confidently use data gathered from mapping volcanic terrains. We present two terrestrial lidar surveys of the recently formed volcanic vent that fed the Holuhraun lava flow in the Northeastern Region of Iceland. While many studies have measured erosion rate at older volcanic vents, these surveys were performed 6 and 18 months after the end of the eruption and present an opportunity to measure morphologic changes at a brand-new vent. The Holuhraun eruption began in August 2014 by effusing lava through a fissure and continued until February 2015, emplacing approximately 1.4 km³ of lava over nearly 85 km². During the eruption the predominant activity at the northern end of the fissure produced a large (50 m high, 500 m long) cinder-canyon with scoria covered flanks. Lava ponded within this vent and drained to form a primary channel to the northeast. As lava drained through the channel, high stands of lava were preserved as "bathtub rings" on the walls of the vent. Following the cessation of activity at Holuhraun, two lidar surveys were carried out inside the vent, in August 2015 and August 2016. A Riegl VZ-400 scanner was used to collect the point cloud data, which give a precise 3D model of the vent with relative accuracy of 15 cm between scan positions. Differences between the two 3D point clouds are used to distinguish between flow emplacement and post-flow modifications to the surface, and to quantify the surface erosion rate experienced by the young vent. Near-infrared (1550 nm wavelength) reflectance values can also be correlated to lava textures and materials within the vent, providing additional information about how the vent was built syn-eruption and how it degrades post-eruption.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Air Pollutants Emissions or a Limit of 20 Parts Per Million by Volume 3 Table 3 to Subpart G of Part... Process Vents, Storage Vessels, Transfer Operations, and Wastewater Pt. 63, Subpt. G, Table 3 Table 3 to.... Recapture devices The appropriate monitoring device identified in table 4 when, in the table, the term...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Air Pollutants Emissions or a Limit of 20 Parts Per Million by Volume 3 Table 3 to Subpart G of Part... Process Vents, Storage Vessels, Transfer Operations, and Wastewater Pt. 63, Subpt. G, Table 3 Table 3 to.... Recapture devices The appropriate monitoring device identified in table 4 when, in the table, the term...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Hazardous Air Pollutants Emissions or a Limit of 20 Parts Per Million by Volume 3 Table 3 to Subpart G of... Process Vents, Storage Vessels, Transfer Operations, and Wastewater Pt. 63, Subpt. G, Table 3 Table 3 to.... Recapture devices The appropriate monitoring device identified in table 4 when, in the table, the term...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Hazardous Air Pollutants Emissions or a Limit of 20 Parts Per Million by Volume 3 Table 3 to Subpart G of... Process Vents, Storage Vessels, Transfer Operations, and Wastewater Pt. 63, Subpt. G, Table 3 Table 3 to.... Recapture devices The appropriate monitoring device identified in table 4 when, in the table, the term...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Hazardous Air Pollutants Emissions or a Limit of 20 Parts Per Million by Volume 3 Table 3 to Subpart G of... Process Vents, Storage Vessels, Transfer Operations, and Wastewater Pt. 63, Subpt. G, Table 3 Table 3 to.... Recapture devices The appropriate monitoring device identified in table 4 when, in the table, the term...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Closed vent systems and control devices; or emissions routed to a fuel gas system or process standards. 63.1034 Section 63.1034 Protection... stringent. The 20 parts per million by volume standard is not applicable to the provisions of § 63.1016. (ii...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 10 2011-07-01 2011-07-01 false Closed vent systems and control devices; or emissions routed to a fuel gas system or process standards. 63.1034 Section 63.1034 Protection... stringent. The 20 parts per million by volume standard is not applicable to the provisions of § 63.1016. (ii...
40 CFR 60.1940 - What definitions must I know?
Code of Federal Regulations, 2014 CFR
2014-07-01
.../combustion unit means a unit that produces gases, liquids, or solids by heating municipal solid waste. The gases, liquids, or solids produced are combusted and the emissions vented to the atmosphere... arithmetic average flue gas temperature measured at the inlet of the particulate matter control device during...
40 CFR 60.1940 - What definitions must I know?
Code of Federal Regulations, 2013 CFR
2013-07-01
.../combustion unit means a unit that produces gases, liquids, or solids by heating municipal solid waste. The gases, liquids, or solids produced are combusted and the emissions vented to the atmosphere... arithmetic average flue gas temperature measured at the inlet of the particulate matter control device during...
40 CFR 60.1940 - What definitions must I know?
Code of Federal Regulations, 2012 CFR
2012-07-01
.../combustion unit means a unit that produces gases, liquids, or solids by heating municipal solid waste. The gases, liquids, or solids produced are combusted and the emissions vented to the atmosphere... arithmetic average flue gas temperature measured at the inlet of the particulate matter control device during...
Poland, Michael P.; Carbone, Daniele
2016-01-01
Continuous gravity data collected near the summit eruptive vent at Kīlauea Volcano, Hawaiʻi, during 2011–2015 show a strong correlation with summit-area surface deformation and the level of the lava lake within the vent over periods of days to weeks, suggesting that changes in gravity reflect variations in volcanic activity. Joint analysis of gravity and lava level time series data indicates that over the entire time period studied, the average density of the lava within the upper tens to hundreds of meters of the summit eruptive vent remained low—approximately 1000–1500 kg/m3. The ratio of gravity change (adjusted for Earth tides and instrumental drift) to lava level change measured over 15 day windows rose gradually over the course of 2011–2015, probably reflecting either (1) a small increase in the density of lava within the eruptive vent or (2) an increase in the volume of lava within the vent due to gradual vent enlargement. Superimposed on the overall time series were transient spikes of mass change associated with inflation and deflation of Kīlauea's summit and coincident changes in lava level. The unexpectedly strong mass variations during these episodes suggest magma flux to and from the shallow magmatic system without commensurate deformation, perhaps indicating magma accumulation within, and withdrawal from, void space—a process that might not otherwise be apparent from lava level and deformation data alone. Continuous gravity data thus provide unique insights into magmatic processes, arguing for continued application of the method at other frequently active volcanoes.
40 CFR 65.143 - Closed vent systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
... storage vessel, process vent, transfer rack, or equipment leaks. (1) Collection of emissions. Each closed... material from a storage vessel, transfer rack or equipment leaks. Inspection records shall be generated as... (B) Conduct annual visual inspections for visible, audible, or olfactory indications of leaks. (ii...
Code of Federal Regulations, 2010 CFR
2010-07-01
... of this subpart apply to Group 2A process vents. (c) Transfer rack requirements. The owner or... route transfer rack emissions through a closed vent system to a flare shall meet the applicable... requirements referenced therein. No other provisions of this subpart apply to transfer rack emissions routed...
NASA Astrophysics Data System (ADS)
Hessler, Robert R.; Smithey, William M.; Boudrias, Michel A.; Keller, Clifford H.; Lutz, Richard A.; Childress, James J.
1988-10-01
Hydrothermal vent communities must undergo substantial temporal change because of their dynamic physical milieu. This was verified in March 1985, when the Rose Garden hydrothermal vent on the Galapagos Rift was revisited after 5 1/4 years' absence. Comparison of photographs from the two visits revealed considerable faunal change. Among the hosts to chemoautotrophic bacteria, vestimentiferans were reduced from dominance to very low numbers. The mytilid was now extremely abundant and dominated vent openings. Vesicomyids also were more abundant. In general, vent-field suspension feeders had declined; anemones were distinctly less abundant, and siphonophores and enteropneusts were virtually absent. The decline of serpulids was likely, but less obvious. Of the mobile scavengers and carnivores, both galatheids and whelks were distincly more common. These community changes appear to result from both continuing recruitment and changes in the physical milieu. While the growth of some populations could have resulted from expanding opportunities, the population of at least one, the vesicomyid, had not achieved carrying capacity in 1979, and this could have pertained to others as well. The decrease of vestimentiferans may have been caused by declining vent-water flux, a process that would favor mytilids, or more complete vent-water filtration by the mytilids themselves. The same factors also could explain the reduction of vent-field filter feeders. These observations suggest that early stages in the cycle of Galapagos-type vent communities are likely to be dominated by vestimentiferans, but that bivalves will replace them with time.
40 CFR 63.118 - Process vent provisions-periodic reporting and recordkeeping requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... device or other means to achieve and maintain a TRE index value greater than 1.0 but less than 4.0 as... subpart and who elects to demonstrate compliance with the TRE index value greater than 4.0 under § 63.113... § 63.115(e) of this subpart, is made that causes a Group 2 process vent with a TRE greater than 4.0 to...
40 CFR 63.118 - Process vent provisions-periodic reporting and recordkeeping requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... device or other means to achieve and maintain a TRE index value greater than 1.0 but less than 4.0 as... subpart and who elects to demonstrate compliance with the TRE index value greater than 4.0 under § 63.113... § 63.115(e) of this subpart, is made that causes a Group 2 process vent with a TRE greater than 4.0 to...
Zero Gravity Cryogenic Vent System Concepts for Upper Stages
NASA Technical Reports Server (NTRS)
Flachbart, Robin H.; Holt, James B.; Hastings, Leon J.
1999-01-01
The capability to vent in zero gravity without resettling is a technology need that involves practically all uses of sub-critical cryogenics in space. Venting without resettling would extend cryogenic orbital transfer vehicle capabilities. However, the lack of definition regarding liquid/ullage orientation coupled with the somewhat random nature of the thermal stratification and resulting pressure rise rates, lead to significant technical challenges. Typically a zero gravity vent concept, termed a thermodynamic vent system (TVS), consists of a tank mixer to destratify the propellant, combined with a Joule-Thomson (J-T) valve to extract thermal energy from the propellant. Marshall Space Flight Center's (MSFC's) Multipurpose Hydrogen Test Bed (MHTB) was used to test both spray bar and axial jet TVS concepts. The axial jet system consists of a recirculation pump heat exchanger unit. The spray bar system consists of a recirculation pump, a parallel flow concentric tube, heat exchanger, and a spray bar positioned close to the longitudinal axis of the tank. The operation of both concepts is similar. In the mixing mode, the recirculation pump withdraws liquid from the tank and sprays it into the tank liquid, ullage, and exposed tank surfaces. When energy is required. a small portion of the recirculated liquid is passed sequentially through the J-T expansion valve, the heat exchanger, and is vented overboard. The vented vapor cools the circulated bulk fluid, thereby removing thermal energy and reducing tank pressure. The pump operates alone, cycling on and off, to destratify the tank liquid and ullage until the liquid vapor pressure reaches the lower set point. At that point. the J-T valve begins to cycle on and off with the pump. Thus, for short duration missions, only the mixer may operate, thus minimizing or even eliminating, boil-off losses.
Microdistribution of Faunal Assemblages at Deep-Sea Hydrothermal Vents in the Southern Ocean
Marsh, Leigh; Copley, Jonathan T.; Huvenne, Veerle A. I.; Linse, Katrin; Reid, William D. K.; Rogers, Alex D.; Sweeting, Christopher J.; Tyler, Paul A.
2012-01-01
Chemosynthetic primary production by microbes supports abundant faunal assemblages at deep-sea hydrothermal vents, with zonation of invertebrate species typically occurring along physico-chemical gradients. Recently discovered vent fields on the East Scotia Ridge (ESR) in the Southern Ocean represent a new province of vent biogeography, but the spatial dynamics of their distinct fauna have yet to be elucidated. This study determines patterns of faunal zonation, species associations, and relationships between faunal microdistribution and hydrothermal activity in a vent field at a depth of 2,400 m on the ESR. Remotely operated vehicle (ROV) dives obtained high-definition imagery of three chimney structures with varying levels of hydrothermal activity, and a mosaic image of >250 m2 of seafloor co-registered with temperature measurements. Analysis of faunal microdistribution within the mosaiced seafloor reveals a consistent pattern of faunal zonation with increasing distance from vent sources and peak temperatures. Assemblages closest to vent sources are visibly dominated by a new species of anomuran crab, Kiwa n. sp. (abundance >700 individuals m−2), followed by a peltospiroid gastropod (>1,500 individuals m−2), eolepadid barnacle (>1,500 individuals m−2), and carnivorous actinostolid anemone (>30 individuals m−2). Peripheral fauna are not dominated by a single taxon, but include predatory and scavenger taxa such as stichasterid seastars, pycnogonids and octopus. Variation in faunal microdistribution on chimneys with differing levels of activity suggests a possible successional sequence for vent fauna in this new biogeographic province. An increase in δ34S values of primary consumers with distance from vent sources, and variation in their δ13C values also indicate possible zonation of nutritional modes of the vent fauna. By using ROV videography to obtain a high-resolution representation of a vent environment over a greater extent than previous studies, these results provide a baseline for determining temporal change and investigations of processes structuring faunal assemblages at Southern Ocean vents. PMID:23144754
Electrolytic pretreatment unit gaseous effluent conditioning
NASA Technical Reports Server (NTRS)
Colombo, G. V.; Putnam, D. F.
1976-01-01
The electrolytic pretreatment of urine is an advanced process that eliminates the need for handling and storing the highly corrosive chemicals that are normally used in water reclamation systems. The electrolytic pretreatment process also converts the organic materials in urine to gases (N2 and O2) that can be used to replenish those lost to space by leakage, venting, and air lock operations. The electrolytic process is more than a pretreatment, since it decreases the urine solids content by approximately one third, thus reducing the load and eventual solids storage requirements of the urine processing system. The evolved gases from the pretreatment step cannot, however, be returned directly to the atmosphere of a spacecraft without first removing several impurities including hydrogen, chlorine, and certain organic compounds. A treatment concept was developed that would decrease the impurities in the gas stream that emanates from an electrolysis unit to levels sufficiently low to allow the conditioned gas stream to be safely discharged to a spacecraft atmosphere. Two methods were experimentally demonstrated that can accomplish the desired cleanup. The bases of the two methods are, repectively: (1) raw urine scrubbing and (2) silica gel sorption.
Code of Federal Regulations, 2014 CFR
2014-07-01
... reduce the vent stream halogen atom mass emission rate to less than 0.45 kilogram per hour prior to a combustion control device in compliance with § 63.113(c)(2) of this subpart shall determine the halogen atom...
Code of Federal Regulations, 2011 CFR
2011-07-01
... reduce the vent stream halogen atom mass emission rate to less than 0.45 kilogram per hour prior to a combustion control device in compliance with § 63.113(c)(2) of this subpart shall determine the halogen atom...
Code of Federal Regulations, 2013 CFR
2013-07-01
... reduce the vent stream halogen atom mass emission rate to less than 0.45 kilogram per hour prior to a combustion control device in compliance with § 63.113(c)(2) of this subpart shall determine the halogen atom...
Code of Federal Regulations, 2012 CFR
2012-07-01
... reduce the vent stream halogen atom mass emission rate to less than 0.45 kilogram per hour prior to a combustion control device in compliance with § 63.113(c)(2) of this subpart shall determine the halogen atom...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-19
... Classification System NF 3 nitrogen trifluoride NODA notice of data availability NTTAA National Technology... Previously Produced Fluorinated GHGs and From Venting of Residual Fluorinated GHGs From Containers 7... emissions from production and transformation processes; emissions from venting of container heels and...
NASA Astrophysics Data System (ADS)
Choi, Kwang Yong; Kim, Yun Chang; Choi, Hee Kwan; Kang, Chul Ho; Kim, Heon Young
2013-12-01
During a sheet metal forming process of automotive outer panels, the air trapped between a blank sheet and a die tool can become highly compressed, ultimately influencing the blank deformation and the press force. To prevent this problem, vent holes are drilled into die tools and needs several tens to hundreds according to the model size. The design and the drilling of vent holes are based on expert's experience and try-out result and thus the process can be one of reasons increasing development cycle. Therefore the study on the size, the number, and the position of vent holes is demanded for reducing development cycle, but there is no simulation technology for analyzing forming defects, making numerical sheet metal forming process simulations that incorporate the fluid dynamics of air. This study presents a sheet metal forming simulation of automotive outer panels (a roof and a body side outer) that simultaneously simulates the behavior of air in a die cavity. Through CAE results, the effect of air behavior and vent holes to blank deformation was analyzed. For this study, the commercial software PAM-STAMP{trade mark, serif} and PAM-SAFE{trade mark, serif} was used.
Flores, Gilberto E.; Campbell, James H.; Kirshtein, Julie D.; Meneghin, Jennifer; Podar, Mircea; Steinberg, Joshua I.; Seewald, Jeffrey S.; Tivey, Margaret Kingston; Voytek, Mary A.; Yang, Zamin K.; Reysenbach, Anna-Louise
2011-01-01
To evaluate the effects of local fluid geochemistry on microbial communities associated with active hydrothermal vent deposits, we examined the archaeal and bacterial communities of 12 samples collected from two very different vent fields: the basalt-hosted Lucky Strike (37°17'N, 32°16.3'W, depth 1600-1750m) and the ultramafic-hosted Rainbow (36°13'N, 33°54.1'W, depth 2270-2330m) vent fields along the Mid-Atlantic Ridge (MAR). Using multiplexed barcoded pyrosequencing of the variable region 4 (V4) of the 16S rRNA genes, we show statistically significant differences between the archaeal and bacterial communities associated with the different vent fields. Quantitative polymerase chain reaction (qPCR) assays of the functional gene diagnostic for methanogenesis (mcrA), as well as geochemical modelling to predict pore fluid chemistries within the deposits, support the pyrosequencing observations. Collectively, these results show that the less reduced, hydrogen-poor fluids at Lucky Strike limit colonization by strict anaerobes such as methanogens, and allow for hyperthermophilic microaerophiles, like Aeropyrum. In contrast, the hydrogen-rich reducing vent fluids at the ultramafic-influenced Rainbow vent field support the prevalence of methanogens and other hydrogen-oxidizing thermophiles at this site. These results demonstrate that biogeographical patterns of hydrothermal vent microorganisms are shaped in part by large scale geological and geochemical processes.
NASA Astrophysics Data System (ADS)
Tunnicliffe, Verena; Fontaine, A. R.
1987-10-01
Examination of a small collection of macroinvertebrates from three vents of the southern Juan de Fuca vent field reveals differences between the vents with respect to species composition, species habits, and microbial and metallic deposits on their surfaces. TWo apparently new vestimentiferan species were found, and for the first time the Juan de Fuca palm worm was observed to dwell on smokers. High acidity values recorded in this system may interfere with the process of shell calcification in an archaeogastropod snail. The surfaces of vestimentifer an tubes at two vents are heavily encrusted with microbial and metallic accumulations. Scanning electron microscope, transmission electron microscope, and energy dispersive X ray microanalysis observations show that iron-based crusts on orange tubes are built from accumulations of an Fe-rich particle of distinctive size and shape. Morphological evidence is presented for the microbial origin of Fe-rich particles. Zn-rich particles found on black tubes are not of microbial origin. We suggest that iron deposition on surfaces in the vent environment is initially biocatalytic but subsequent deposits may build by simple inorganic reactions.
75 FR 65032 - Notice of Lodging of Consent Decree
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-21
... absorber vent as a Group 2 process vent under the Hazardous Organic NESHAP regulations. For three years, Westlake will also implement an enhanced Leak Detection and Repair program to control emissions of...'s common control, and Westlake will not contest administratively or judicially a finding by the...
40 CFR 63.1259 - Recordkeeping requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... required by § 63.1253(f)(2) and the pressure relief vent setting and the leak detection records specified... human health or the environment than if the storage tanks and process vents were controlled according to... guidance that the Administrator makes available for use or any other technically sound information or...
40 CFR 63.1332 - Emissions averaging provisions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... other controls for a Group 1 storage vessel, batch process vent, aggregate batch vent stream, continuous... in control after November 15, 1990. (2) Group 1 emission points, identified in paragraph (c)(3) of... applicable reference control technology or standard and the emissions allowed for the Group 1 emission point...
40 CFR 63.1332 - Emissions averaging provisions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... other controls for a Group 1 storage vessel, batch process vent, aggregate batch vent stream, continuous... in control after November 15, 1990. (2) Group 1 emission points, identified in paragraph (c)(3) of... reference control technology or standard and the emissions allowed for the Group 1 emission point. Said...
40 CFR 65.163 - Other records.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) Detailed schematics, design specifications of the control device, and piping and instrumentation diagrams... FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas System or a Process § 65... bypass lines that could divert a vent stream away from the control device and to the atmosphere, the...
40 CFR 98.127 - Records that must be retained.
Code of Federal Regulations, 2014 CFR
2014-07-01
... destruction device, a facility may track dates and time periods that process vents by-pass the destruction... in your GHG Monitoring Plan. (g) Container heel records. If you vent residual fluorinated GHGs from containers, maintain the following records of the measurements and calculations used to estimate emissions of...
40 CFR 98.127 - Records that must be retained.
Code of Federal Regulations, 2012 CFR
2012-07-01
... destruction device, a facility may track dates and time periods that process vents by-pass the destruction... in your GHG Monitoring Plan. (g) Container heel records. If you vent residual fluorinated GHGs from containers, maintain the following records of the measurements and calculations used to estimate emissions of...
40 CFR 98.127 - Records that must be retained.
Code of Federal Regulations, 2013 CFR
2013-07-01
... destruction device, a facility may track dates and time periods that process vents by-pass the destruction... in your GHG Monitoring Plan. (g) Container heel records. If you vent residual fluorinated GHGs from containers, maintain the following records of the measurements and calculations used to estimate emissions of...
40 CFR 98.127 - Records that must be retained.
Code of Federal Regulations, 2011 CFR
2011-07-01
... destruction device, a facility may track dates and time periods that process vents by-pass the destruction... in your GHG Monitoring Plan. (g) Container heel records. If you vent residual fluorinated GHGs from containers, maintain the following records of the measurements and calculations used to estimate emissions of...
Arnal, Jean-Michel; Garnero, Aude; Novotni, Dominik; Corno, Gaëlle; Donati, Stéphane-Yannis; Demory, Didier; Quintana, Gabrielle; Ducros, Laurent; Laubscher, Thomas; Durand-Gasselin, Jacques
2018-01-01
There is an equipoise regarding closed-loop ventilation modes and the ability to reduce workload for providers. On one hand some settings are managed by the ventilator but on another hand the automatic mode introduces new settings for the user. This randomized controlled trial compared the number of manual ventilator setting changes between a full closed loop ventilation and oxygenation mode (INTELLiVENT-ASV®) and conventional ventilation modes (volume assist control and pressure support) in Intensive Care Unit (ICU) patients. The secondary endpoints were to compare the number of arterial blood gas analysis, the sedation dose and the user acceptance. Sixty subjects with an expected duration of mechanical ventilation of at least 48 hours were randomized to be ventilated using INTELLiVENT-ASV® or conventional modes with a protocolized weaning. All manual ventilator setting changes were recorded continuously from inclusion to successful extubation or death. Arterial blood gases were performed upon decision of the clinician in charge. User acceptance score was assessed for nurses and physicians once daily using a Likert Scale. The number of manual ventilator setting changes per 24 h-period per subject was lower in INTELLiVENT-ASV® as compared to conventional ventilation group (5 [4-7] versus 10 [7-17]) manuals settings per subject per day [P<0.001]). The number of arterial blood gas analysis and the sedation doses were not significantly different between the groups. Nurses and physicians reported that INTELLiVENT-ASV® was significantly easier to use as compared to conventional ventilation (P<0.001 for nurses and P<0.01 for physicians). For mechanically ventilated ICU patients, INTELLiVENT-ASV® significantly reduces the number of manual ventilator setting changes with the same number of arterial blood gas analysis and sedation dose, and is easier to use for the caregivers as compared to conventional ventilation modes.
Vent Processes and Deposits of a Hiatus in a Violent Eruption: Quilotoa Volcano, Ecuador
NASA Astrophysics Data System (ADS)
Best, J. A.; Bustillos, J.; Ort, M. H.; Cashman, K. V.; Mothes, P. A.; di Muro, A.; Rosi, M.
2009-12-01
The 800 BP eruption of Quilotoa volcano, Ecuador, produced two plinian eruptions separated by a short (days-weeks) hiatus. We examine the tephra produced both during this hiatus and erupted at the onset of the second Plinian eruption. Units 1 and 3 (U1 and U3) of the eruption correspond to the first and second Plinian eruptions, respectively, and produced fallout and pyroclastic density currents. Unit 2 (U2) records processes during the hiatus and consists of two subunits: U2a, a vitric ashfall, and U2b, a crystal and lithic-rich fallout. 130 individual tephra samples of U1, U2, and U3 were collected from 24 sites along three radial transects from the volcano in January 2009. Thickness and grain-size features were described, with particular attention paid to U2. Grain-size and componentry analysis of a subset of these samples reveals a number of trends. The upper part of U1 is massive and normally graded at its top. This part of U1 is dominantly vitric ash smaller than 3.0 φ and likely represents the clearing of the air at the end of the first plinian eruption. U2a has a polymodal distribution with a large fraction of 4.0 φ and finer vitric material. Dune forms occur in this unit, which is interpreted to be the product of surges. U2b is coarser overall with alternating fine- (2-3φ) and coarse- (1-2φ) grained layers. The beds have a unimodal grain-size distribution and normal grading. U2b is interpreted as a fall deposit. The U2a/U2b contact is gradational in that 0-2 beds of U2b material occur within the uppermost U2a beds, indicating vent conditions for both briefly coexisted. U2c is a <2-cm-thick vitric ash with sparse crystal-rich lava lapilli. These lapilli also occur in the overlying basal U3 fallout, which has a polymodal grain-size distribution. Some U2b pumice fragments and crystals are stained orange, which gives U2b its characteristic color. Stained grains are also present but rare in other units and may have been sourced from the conduit walls. The high proportion of stained fragments in U2b requires a different, possibly hydrothermal, source. We interpret the lava lapilli of U2c and U3 as being from a single explosion, perhaps the opening of a new vent, and thus they indicate that the eruption was continuous from U2b through U3. Our current hypothesis is that, as the U1 eruption ended, acidic gas streamed through the material clogging the vent. This elutriated vitric material that eventually formed a cap on the system. As the U3 magma began its ascent, gas flux increased, leading to explosions that gradually removed the vitric cap and depositing the vitric U2a. Then, more continuous gas streaming led to the development of an pulsatory eruption column that carried the hot stained crystals and lithic fragments into a convecting column and eventual deposition as fallout of U2b, which was then followed by the establishment of the U3 eruption column.
The vent microbiome: patterns and drivers
NASA Astrophysics Data System (ADS)
Pachiadaki, M.
2015-12-01
Microbial processes within deep-sea hydrothermal vents affect the global biogeochemical cycles. Still, there are significant gaps in our understanding of the microbiology and the biogeochemistry of deep-sea hydrothermal systems. Vents differ in temperature, host rock composition and fluid chemistry; factors that are hypothesized to shape the distribution of the microbial communities, their metabolic capabilities and their activities. Using large-scale single cell genomics, we obtained insights into the genomic content of several linkages of a diffuse flow vent. The genomes show high metabolic versatility. Sulfur oxidation appears to be predominant but there is the potential of using a variety of e- donors and acceptors to obtain energy. To further assess the ecological importance of the vent auto- and heterotrophs, the global biogeography of the analyzed lineages will be investigated by fragment recruitment of metagenomes produced from the same site as well as other hydrothermal systems. Metatranscriptomic and metaproteomic data will be integrated to examine the expression of the predominant metabolic pathways and thus the main energy sources driving chemoautotrophic production. The comparative analysis of the key players and associated pathways among various vent sites that differ in physicochemical characteristics is anticipated to decipher the patterns and drivers of the global dispersion and the local diversification of the vent microbiome.
NASA Astrophysics Data System (ADS)
Trocine, Robert P.; Trefry, John H.
1988-04-01
Suspended particles were collected from an area of active hydrothermal venting at the Trans-Atlantic Geotraverse (TAG) Hydrothermal Field on the Mid-Atlantic Ridge and analyzed for Fe, Mn, Cd, Zn, Cu, V, Ni, Cr, Pb, Mg, Ca, Al and Si. Rapid advection of vent-derived precipitates produced a lens with total suspended matter (TSM) loadings of 14-60 μg/l at 200-700 m above the seafloor; TSM concentrations > 60 μg/l were observed only at near-vent sites. The distribution of suspended particles correlated well with increased dissolved Mn concentrations and particulate Fe values near the vent source. Particulate Fe values decreased linearly relative to TSM concentrations as hydrothermal precipitates mixed with background suspended matter. Near-vent precipitates were characterized by up to 35% Fe, 2% Zn, 0.6% Cu and > 100 μg/g Cd. In comparison to Fe, particulate Cd, Zn and Cu values decreased dramatically away from the vent source. This trend supports differential settling and/or dissolution of Cd-, Zn- and Cu-bearing phases. Particulate Mn and Fe values were inversely related with only 50 μg Mn/g in the near-vent particles. At near-vent sites, > 99% of the total Mn was in solution; this fraction decreased to 75-80% at background TSM values. In contrast to Cd, Zn and Cu, particulate V levels show a continuous, linear decrease with particulate Fe values. This trend is explained by adsorption of V on Fe-oxides in the vent plume. Scavenging of Cr, Pb and Mg by hydrothermal precipitates is also suggested by the data. Nickel and Al values were low in near-vent particles at < 100 and < 3 μg/g, respectively. The complementary behavior of dissolved Mn and particulate trace metals provides a useful framework for studying broad aspects of hydrothermal plume processes.
46 CFR 154.519 - Piping relief valves.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Process Piping Systems § 154.519 Piping relief valves. (a) The liquid relief valve that protects the cargo piping system from liquid pressure exceeding the design pressure must discharge into: (1) A cargo tank; or (2) A cargo vent mast if that vent mast has a means for the detection and removal of the liquid...
46 CFR 154.519 - Piping relief valves.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Process Piping Systems § 154.519 Piping relief valves. (a) The liquid relief valve that protects the cargo piping system from liquid pressure exceeding the design pressure must discharge into: (1) A cargo tank; or (2) A cargo vent mast if that vent mast has a means for the detection and removal of the liquid...
46 CFR 154.519 - Piping relief valves.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Process Piping Systems § 154.519 Piping relief valves. (a) The liquid relief valve that protects the cargo piping system from liquid pressure exceeding the design pressure must discharge into: (1) A cargo tank; or (2) A cargo vent mast if that vent mast has a means for the detection and removal of the liquid...
46 CFR 154.519 - Piping relief valves.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Process Piping Systems § 154.519 Piping relief valves. (a) The liquid relief valve that protects the cargo piping system from liquid pressure exceeding the design pressure must discharge into: (1) A cargo tank; or (2) A cargo vent mast if that vent mast has a means for the detection and removal of the liquid...
40 CFR 65.150 - Absorbers used as control devices.
Code of Federal Regulations, 2014 CFR
2014-07-01
... control device on a Group 1 process vent or a high-throughput transfer rack with an absorber used as a... 40 Protection of Environment 16 2014-07-01 2014-07-01 false Absorbers used as control devices. 65... (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas...
40 CFR 65.150 - Absorbers used as control devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... control device on a Group 1 process vent or a high-throughput transfer rack with an absorber used as a... 40 Protection of Environment 15 2010-07-01 2010-07-01 false Absorbers used as control devices. 65... (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas...
40 CFR 65.150 - Absorbers used as control devices.
Code of Federal Regulations, 2011 CFR
2011-07-01
... control device on a Group 1 process vent or a high-throughput transfer rack with an absorber used as a... 40 Protection of Environment 15 2011-07-01 2011-07-01 false Absorbers used as control devices. 65... (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a Fuel Gas...
40 CFR 65.152 - Carbon adsorbers used as control devices.
Code of Federal Regulations, 2011 CFR
2011-07-01
... control device. If an owner or operator elects to replace a control device on a Group 1 process vent or... 40 Protection of Environment 15 2011-07-01 2011-07-01 false Carbon adsorbers used as control... PROGRAMS (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Closed Vent Systems, Control Devices, and Routing to a...
Ash production and dispersal from sustained low-intensity Mono-Inyo eruptions
NASA Astrophysics Data System (ADS)
Black, Benjamin A.; Manga, Michael; Andrews, Benjamin
2016-08-01
Recent rhyolitic volcanism has demonstrated that prolonged low-intensity ash venting may accompany effusive dome formation. We examine the possibility and some consequences of episodes of extended, weak ash venting at the rhyolitic Mono-Inyo chain in Eastern California. We describe ash-filled cracks within one of the youngest domes, Panum Crater, which provide a textural record of ash venting during dome effusion. We use synchrotron-based X-ray computed tomography to characterize the particles in these tuffisites. Particle sizes in well-sorted tuffisite layers agree well with grain size distributions observed during weak ash venting at Soufrière Hills Volcano, Montserrat, and yield approximate upper and lower bounds on gas velocity and mass flux during the formation of those layers. We simulate ash dispersal with Ash3d to assess the consequences of long-lived Mono-Inyo ash venting for ash deposition and the accompanying volcanic hazards. Our results highlight the sensitivity of large-scale outcomes of volcanic eruptions to small-scale processes.
Measure Guideline: Passive Vents
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berger, David; Neri, Robin
2016-02-05
This document addresses the use of passive vents as a source of outdoor air in multifamily buildings. The challenges associated with implementing passive vents and the factors affecting performance are outlined. A comprehensive design methodology and quantified performance metrics are provided. Two hypothetical design examples are provided to illustrate the process. This document is intended to be useful to designers, decision-makers, and contractors implementing passive ventilation strategies. It is also intended to be a resource for those responsible for setting high-performance building program requirements, especially pertaining to ventilation and outdoor air. To ensure good indoor air quality, a dedicated sourcemore » of outdoor air is an integral part of high-performance buildings. Presently, there is a lack of guidance pertaining to the design and installation of passive vents, resulting in poor system performance. This report details the criteria necessary for designing, constructing, and testing passive vent systems to enable them to provide consistent and reliable levels of ventilation air from outdoors.« less
Whitmyre, Gary K; Pandian, Muhilan D
2018-06-01
Use of vent-free gas heating appliances for supplemental heating in U.S. homes is increasing. However, there is currently a lack of information on the potential impact of these appliances on indoor air quality for homes constructed according to energy-efficient and green building standards. A probabilistic analysis was conducted to estimate the impact of vent-free gas heating appliances on indoor air concentrations of carbon monoxide (CO), nitrogen dioxide (NO 2 ), carbon dioxide (CO 2 ), water vapor, and oxygen in "tight" energy-efficient homes in the United States. A total of 20,000 simulations were conducted for each Department of Energy (DOE) heating region to capture a wide range of home sizes, appliance features, and conditions, by varying a number of parameters, e.g., room volume, house volume, outdoor humidity, air exchange rates, appliance input rates (Btu/hr), and house heat loss factors. Predicted airborne levels of CO were below the U.S. Environmental Protection Agency (EPA) standard of 9 ppm for all modeled cases. The airborne concentrations of NO 2 were below the U.S. Consumer Product Safety Commission (CPSC) guideline of 0.3 ppm and the Health Canada benchmark of 0.25 ppm in all cases and were below the World Health Organization (WHO) standard of 0.11 ppm in 99-100% of all cases. Predicted levels of CO 2 were below the Health Canada standard of 3500 ppm for all simulated cases. Oxygen levels in the room of vent-free heating appliance use were not significantly reduced. The great majority of cases in all DOE regions were associated with relative humidity (RH) levels from all indoor water vapor sources that were less than the EPA-recommended 70% RH maximum to avoid active mold and mildew growth. The conclusion of this investigation is that when installed in accordance with the manufacturer's instructions, vent-free gas heating appliances maintain acceptable indoor air quality in tight energy-efficient homes, as defined by the standards referenced in this report. Probabilistic modeling of indoor air concentrations of carbon monoxide (CO), nitrogen dioxide (NO 2 ), carbon dioxide (CO 2 ), water vapor, and oxygen associated with use of vent-free gas heating appliances provides new data indicating that uses of these devices are consistent with acceptable indoor air quality in "tight" energy-efficient homes in the United States. This study will provide authoritative bodies such as the International Code Council with definitive information that will assist in the development of future versions of national building codes, and will provide evaluation of the performance of unvented gas heating products in energy conservation homes.
40 CFR 61.349 - Standards: Closed-vent systems and control devices.
Code of Federal Regulations, 2013 CFR
2013-07-01
... the unit in accordance with good engineering and safety practices for handling flammable, explosive... device shall be made as soon as practicable but no later than 5 calendar days after detection. Repair...
40 CFR 61.349 - Standards: Closed-vent systems and control devices.
Code of Federal Regulations, 2014 CFR
2014-07-01
... the unit in accordance with good engineering and safety practices for handling flammable, explosive... device shall be made as soon as practicable but no later than 5 calendar days after detection. Repair...
Heterotrophic Proteobacteria in the vicinity of diffuse hydrothermal venting.
Meier, Dimitri V; Bach, Wolfgang; Girguis, Peter R; Gruber-Vodicka, Harald R; Reeves, Eoghan P; Richter, Michael; Vidoudez, Charles; Amann, Rudolf; Meyerdierks, Anke
2016-12-01
Deep-sea hydrothermal vents are highly dynamic habitats characterized by steep temperature and chemical gradients. The oxidation of reduced compounds dissolved in the venting fluids fuels primary production providing the basis for extensive life. Until recently studies of microbial vent communities have focused primarily on chemolithoautotrophic organisms. In our study, we targeted the change of microbial community compositions along mixing gradients, focusing on distribution and capabilities of heterotrophic microorganisms. Samples were retrieved from different venting areas within the Menez Gwen hydrothermal field, taken along mixing gradients, including diffuse fluid discharge points, their immediate surroundings and the buoyant parts of hydrothermal plumes. High throughput 16S rRNA gene amplicon sequencing, fluorescence in situ hybridization, and targeted metagenome analysis were combined with geochemical analyses. Close to diffuse venting orifices dominated by chemolithoautotrophic Epsilonproteobacteria, in areas where environmental conditions still supported chemolithoautotrophic processes, we detected microbial communities enriched for versatile heterotrophic Alpha- and Gammaproteobacteria. The potential for alkane degradation could be shown for several genera and yet uncultured clades. We propose that hotspots of chemolithoautotrophic life support a 'belt' of heterotrophic bacteria significantly different from the dominating oligotrophic microbiota of the deep sea. © 2016 Society for Applied Microbiology and John Wiley & Sons Ltd.
NASA Technical Reports Server (NTRS)
Bishop, J. L.; Murchie, S.; Pieters, C.; Zent, A.
1999-01-01
This model is one of many possible scenarios to explain the generation of the current surface material on Mars using chemical, magnetic and spectroscopic data from Mars and geologic analogs from terrestrial sites. One basic premise is that there are physical and chemical interactions of the atmospheric dust particles and that these two processes create distinctly different results. Physical processes distribute dust particles on rocks, forming physical rock coatings, and on the surface between rocks forming soil units; these are reversible processes. Chemical reactions of the dust/soil particles create alteration rinds on rock surfaces or duricrust surface units, both of which are relatively permanent materials. According to this model the mineral components of the dust/soil particles are derived from a combination of "typical" palagonitic weathering of volcanic ash and hydrothermally altered components, primarily from steam vents or fumeroles. Both of these altered materials are composed of tiny particles, about 1 micron or smaller, that are aggregates of silicates and iron oxide/oxyhydroxide/sulfate phases. Additional information is contained in the original extended abstract.
NASA Astrophysics Data System (ADS)
Sohn, Y.
2011-12-01
Recent studies show that the architecture of hydromagmatic volcanoes is far more complex than formerly expected. A number of external factors, such as paleohydrology and tectonics, in addition to magmatic processes are thought to play a role in controlling the overall characteristics and architecture of these volcanoes. One of the main consequences of these controls is the migration of the active vent during eruption. Case studies of hydromagmatic volcanoes in Korea show that those volcanoes that have undergone vent migration are characterized by superposition or juxtaposition of multiple rim deposits of partial tuff rings and/or tuff cones that have contrasting lithofacies characteristics, bed attitudes, and paleoflow directions. Various causes of vent migration are inferred from these volcanoes. Large-scale collapse of fragile substrate is interpreted to have caused vent migration in the Early Pleistocene volcanoes of Jeju Island, which were built upon still unconsolidated continental shelf sediments. Late Pleistocene to Holocene volcanoes, which were built upon a stack of rigid, shield-forming lava flows, lack features due to large-scale substrate collapse and have generally simple and circular morphologies either of a tuff ring or of a tuff cone. However, ~600 m shift of the eruptive center is inferred from one of these volcanoes (Ilchulbong tuff cone). The vent migration in this volcano is interpreted to have occurred because the eruption was sourced by multiple magma batches with significant eruptive pauses in between. The Yangpori diatreme in a Miocene terrestrial half-graben basin in SE Korea is interpreted to be a subsurface equivalent of a hydromagmatic volcano that has undergone vent migration. The vent migration here is inferred to have had both vertical and lateral components and have been caused by an abrupt tectonic activity near the basin margin. In all these cases, rimbeds or diatreme fills derived from different source vents are bounded by either prominent or subtle, commonly laterally extensive truncation surfaces or stratigraphic discontinuities. Careful documentation of these surfaces and discontinuities thus appears vital to proper interpretation of eruption history, morphologic evolution, and even deep-seated magmatic processes of a hydromagmatic volcano. In this respect, the technique known as 'allostratigraphy' appears useful in mapping, correlation, and interpretation of many hydrovolcanic edifices and sequences.
NASA Astrophysics Data System (ADS)
Witt, Tanja; Walter, Thomas R.
2017-01-01
Lava fountains are a common eruptive feature of basaltic volcanoes. Many lava fountains result from fissure eruptions and are associated with the alignment of active vents and rising gas bubbles in the conduit. Visual reports suggest that lava fountain pulses may occur in chorus at adjacent vents. The mechanisms behind such a chorus of lava fountains and the underlying processes are, however, not fully understood. The March 2011 eruption at Pu'u 'Ō'ō (Kilauea volcano) was an exceptional fissure eruption that was well monitored and could be closely approached by field geologists. The fissure eruption occurred along groups of individual vents aligned above the feeding dyke. We investigate video data acquired during the early stages of the eruption to measure the height, width and velocity of the ejecta leaving eight vents. Using a Sobel edge-detection algorithm, the activity level of the lava fountains at the vents was determined, revealing a similarity in the eruption height and frequency. Based on this lava fountain time series, we estimate the direction and degree of correlation between the different vents. We find that the height and velocity of the eruptions display a small but systematic shift in time along the vents, indicating a lateral migration of lava fountaining at a rate of 11 m/s from W to E. This finding is in agreement with a propagation model of a pressure wave originating at the Kilauea volcano and propagating through the dyke at 10 m/s from W to E. Based on this approach from videos only 30 s long, we are able to obtain indirect constraints on the physical dyke parameters, with important implications for lateral magma flow processes at depth. This work shows that the recording and analysis of video data provide important constraints on the mechanisms of lava fountain pulses. Even though the video sequence is short, it allows for the confirmation of the magma propagation direction and a first-order estimation of the dyke dimensions.
NASA Astrophysics Data System (ADS)
Anderson, J.; Johnson, J. B.; Steele, A. L.; Anzieta, J. C.; Ortiz, H. D.; Hall, M. L.; Ruiz, M. C.
2014-12-01
Acoustic recordings reveal a variety of volcanic activities during an exceptionally loud vulcanian eruption at Tungurahua. A period of several months of mild surface activity came to an abrupt end with the emission of a powerful blast wave heard at least 180 km away. Sensors 2080 m from the vent recorded a stepped rise to its maximum overpressure of 1220 Pa (corresponding to a sound pressure level of 156 dB) and its unusually long dominant period of 5.6 s. We discuss source processes that produced the blast wave, considering that wave propagation could be nonlinear near the vent because of high overpressures. More than an hour of acoustic activity was recorded after the blast wave, including sound from falling ballistics, reflections of the blast wave from nearby mountains, pyroclastic density currents, and acoustic tremor at the vent. Glitches in the acoustic records related to plume lightning were also serendipitously observed, although thunder could not be unambiguously identified. We discuss acoustic signatures of falling ballistics and pyroclastic density currents and how array-style deployments and analytic methods can be used to reveal them. Placement of sensors high on the volcano's slopes facilitated resolving these distinct processes. This study demonstrates that near-vent, array-style acoustic installations can be used to monitor various types of volcanic activity.
Development and relationship of monogenetic and polygenetic volcanic fields in time and space.
NASA Astrophysics Data System (ADS)
Germa, Aurelie; Connor, Chuck; Connor, Laura; Malservisi, Rocco
2013-04-01
The classification of volcanic systems, developed by G. P. L. Walker and colleagues, relates volcano morphology to magma transport and eruption processes. In general, distributed monogenetic volcanic fields are characterized by infrequent eruptions, low average output rate, and a low spatial intensity of the eruptive vents. In contrast, central-vent-dominated systems, such as stratovolcanoes, central volcanoes and lava shields are characterized by frequent eruptions, higher average flux rates, and higher spatial intensity of eruptive vents. However, it has been observed that a stratovolcano is often associated to parasitic monogenetic vents on its flanks, related to the central silicic systems, and surrounded by an apron of monogenetic edifices that are part of the volcanic field but independent from the principal central system. It appears from spatial distribution and time-volume relationships that surface area of monogenetic fields reflects the lateral extent of the magma source region and the lack of magma focusing mechanisms. In contrast, magma is focused through a unique conduit system for polygenetic volcanoes, provided by a thermally and mechanically favorable pathway toward the surface that is maintained by frequent and favorable stress conditions. We plan to relate surface observations of spatio-temporal location of eruptive vents and evolution of the field area through time to processes that control magma focusing during ascent and storage in the crust. We choose to study fields that range from dispersed to central-vent dominated, through transitional fields (central felsic system with peripheral field of monogenetic vents independent from the rhyolitic system). We investigate different well-studied volcanic fields in the Western US and Western Europe in order to assess influence of the geodynamic setting and tectonic stress on the spatial distribution of magmatism. In summary, incremental spatial intensity maps should reveal how fast a central conduit is created during the development of a volcanic field, and how this could influence the outbreak of dispersed monogenetic volcanoes that are not geochemically linked to the central system.
1997-04-16
An oxygen generator destined to replace a malfunctioning unit on the Russian Mir Space Station is the object of much curiosity during preflight preparations in the SPACEHAB Payload Processing Facility. A SPACEHAB Double Module on the Space Shuttle Atlantis will carry the oxygen generator to Mir during STS-84, the sixth Shuttle-Mir docking. The nearly 300-pound generator, manufactured by RSC Energia in Russia, will replace one of two Mir units that have been malfunctioning recently. The generator functions by electrolysis, which separates water into its oxygen and hydrogen components. The hydrogen is vented and the oxygen is used for breathing by the Mir crew. The generator is 4.2 feet in length and 1.4 feet in diameter. STS-84, which is planned to include a Mir crew exchange of astronaut C. Michael Foale for Jerry M. Linenger, is targeted for a May 15 liftoff
9 CFR 381.305 - Equipment and procedures for heat processing systems.
Code of Federal Regulations, 2014 CFR
2014-01-01
... plates. Whenever one or more divider plates are used between any two layers of containers or placed on... from several still retorts shall lead to the atmosphere. The manifold header shall not be controlled by...) Venting through multiple 1 inch (2.5 cm) vents discharging directly to the atmosphere. EC11SE91.047...
9 CFR 381.305 - Equipment and procedures for heat processing systems.
Code of Federal Regulations, 2012 CFR
2012-01-01
... plates. Whenever one or more divider plates are used between any two layers of containers or placed on... from several still retorts shall lead to the atmosphere. The manifold header shall not be controlled by...) Venting through multiple 1 inch (2.5 cm) vents discharging directly to the atmosphere. EC11SE91.047...
9 CFR 381.305 - Equipment and procedures for heat processing systems.
Code of Federal Regulations, 2013 CFR
2013-01-01
... plates. Whenever one or more divider plates are used between any two layers of containers or placed on... from several still retorts shall lead to the atmosphere. The manifold header shall not be controlled by...) Venting through multiple 1 inch (2.5 cm) vents discharging directly to the atmosphere. EC11SE91.047...
Code of Federal Regulations, 2010 CFR
2010-07-01
... conduct a performance test to determine percent emission reduction or outlet organic HAP or TOC... organic HAP concentration and percent reduction may be measured as either total organic HAP or as TOC... measurement of total organic HAP or TOC (minus methane and ethane) concentrations in all vent streams and...
40 CFR Table 5 of Subpart Bbbbbbb... - Reporting Requirements
Code of Federal Regulations, 2013 CFR
2013-07-01
... vent streams from equipment in target HAP service to a PM control device with a PM percent reduction efficiency of 95 percent (98 percent for new sources) or an outlet concentration of 0.03 gr/dscf or less a... requirement to route all process vent streams from equipment in target HAP service to a PM control device that...
40 CFR Table 5 of Subpart Bbbbbbb... - Reporting Requirements
Code of Federal Regulations, 2014 CFR
2014-07-01
... vent streams from equipment in target HAP service to a PM control device with a PM percent reduction efficiency of 95 percent (98 percent for new sources) or an outlet concentration of 0.03 gr/dscf or less a... requirement to route all process vent streams from equipment in target HAP service to a PM control device that...
40 CFR Table 5 of Subpart Bbbbbbb... - Reporting Requirements
Code of Federal Regulations, 2012 CFR
2012-07-01
... vent streams from equipment in target HAP service to a PM control device with a PM percent reduction efficiency of 95 percent (98 percent for new sources) or an outlet concentration of 0.03 gr/dscf or less a... requirement to route all process vent streams from equipment in target HAP service to a PM control device that...
40 CFR Table 5 of Subpart Bbbbbbb... - Reporting Requirements
Code of Federal Regulations, 2010 CFR
2010-07-01
... vent streams from equipment in target HAP service to a PM control device with a PM percent reduction efficiency of 95 percent (98 percent for new sources) or an outlet concentration of 0.03 gr/dscf or less a... requirement to route all process vent streams from equipment in target HAP service to a PM control device that...
40 CFR Table 5 of Subpart Bbbbbbb... - Reporting Requirements
Code of Federal Regulations, 2011 CFR
2011-07-01
... vent streams from equipment in target HAP service to a PM control device with a PM percent reduction efficiency of 95 percent (98 percent for new sources) or an outlet concentration of 0.03 gr/dscf or less a... requirement to route all process vent streams from equipment in target HAP service to a PM control device that...
Code of Federal Regulations, 2013 CFR
2013-07-01
... performance test for those control techniques in accordance with paragraph (b)(6) of this section. The design..., immediately preceding the use of the control technique. A design evaluation shall also address other vent... paragraph (f)(1)(i) of this section, the design evaluation shall document the control efficiency and address...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Hazardous Air Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Continuous Compliance... each by-product hydrogen stream, end box ventilation system vent, and mercury thermal recovery unit...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Hazardous Air Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Continuous Compliance... each by-product hydrogen stream, end box ventilation system vent, and mercury thermal recovery unit...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Hazardous Air Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Continuous Compliance... each by-product hydrogen stream, end box ventilation system vent, and mercury thermal recovery unit...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Hazardous Air Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Continuous Compliance... each by-product hydrogen stream, end box ventilation system vent, and mercury thermal recovery unit...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Hazardous Air Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Continuous Compliance... each by-product hydrogen stream, end box ventilation system vent, and mercury thermal recovery unit...
NASA Astrophysics Data System (ADS)
Arnulf, A. F.; Harding, A. J.; Kent, G. M.
2016-12-01
The Endeavour segment is a 90 km-long, medium-spreading-rate, oceanic spreading center located on the northern Juan de Fuca ridge (JDFR). The central part of this segment forms a 25-km-long volcanic high that hosts five of the most hydrothermally active vent fields on the MOR system, namely (from north to south): Sasquatch, Salty Dawg, High Rise, Main Endeavour and Mothra. Mass, heat and chemical fluxes associated to vigorous hydrothermal venting are large, however the geometry of the fluid circulation system through the oceanic crust remains almost completely undefined. To produce high-resolution velocity/reflectivity structures along the axis of the Endeavour segment, here, we combined a synthetic ocean bottom experiment (SOBE), 2-D traveltime tomography, 2D elastic full waveform and reverse time migration (RTM). We present velocity and reflectivity sections along Endeavour segment at unprecedented spatial resolutions. We clearly image a set of independent, geometrically complex, elongated low-velocity regions linking the top of the magma chamber at depth to the hydrothermal vent fields on the seafloor. We interpret these narrow pipe-like units as focused regions of hydrothermal fluid up-flow, where acidic and corrosive fluids form pipe-like alteration zones as previously observed in Cyprus ophiolites. Furthermore, the amplitude of these low-velocity channels is shown to be highly variable, with the strongest velocity drops observed at Main Endeavour, Mothra and Salty Dawg hydrothermal vent fields, possibly suggesting more mature hydrothermal cells. Interestingly, the near-seafloor structure beneath those three sites is very similar and highlights a sharp lateral transition in velocity (north to south). On the other hand, the High-Rise hydrothermal vent field is characterized by several lower amplitudes up-flow zones and relatively slow near-surface velocities. Last, Sasquatch vent field is located in an area of high near-surface velocities and is not characterized by an obvious low-velocity up-flow region, in good agreement with an extinct vent field.
Geology and geochemistry of gas-charged sediment on Kodiak Shelf, Alaska
Hampton, M.A.; Kvenvolden, K.A.
1981-01-01
Methane concentrations in some sediment cores from the Kodiak Shelf and adjacent continental slope increase with depth by three or four orders of magnitude and exceed the solubility in water at ambient conditions. Acoustic anomalies in seismic-reflection records imply that methane-rich sediment is widespread. Molecular composition of hydrocarbon gases and isotopic composition of methane indicate gas formation by shallow biogenic processes. Stratigraphic positions of acoustic anomalies in Quaternary glacial and posttransgressive sediments suggest that these units are likely sources of gas. A seep along the extension of a fault may be gas venting from a deeper thermogenic source. ?? 1981 A.M. Dowden, Inc.
Chemical looping integration with a carbon dioxide gas purification unit
Andrus, Jr., Herbert E.; Jukkola, Glen D.; Thibeault, Paul R.; Liljedahl, Gregory N.
2017-01-24
A chemical looping system that contains an oxidizer and a reducer is in fluid communication with a gas purification unit. The gas purification unit has at least one compressor, at least one dryer; and at least one distillation purification system; where the gas purification unit is operative to separate carbon dioxide from other contaminants present in the flue gas stream; and where the gas purification unit is operative to recycle the contaminants to the chemical looping system in the form of a vent gas that provides lift for reactants in the reducer.
NASA Astrophysics Data System (ADS)
Thomas, Rebecca J.
2013-04-01
In order to investigate sources of lava and water to the Cerberus plains of Mars, geomorphological mapping on High Resolution Imaging Science Experiment (HiRISE) images was carried out to reveal the history of activity of fissures and pits which lie upstream of channels and deposits associated with a wrinkle ridge near Cerberus Fossae. The fissures and pits are superbly exposed and imaged, and flows and channels emanate directly from them, interpreted as clear evidence that these are vents. The mapping establishes stratigraphic relationships between the plains and the channels and deposits originating from the vents, establishing the vent history. For example, to the south of the wrinkle ridge, both incised channels and leveed flows extend onto the southern plain and are clearly the final phase of plains-forming activity. Conversely, to the north, vent-sourced channels only incise the plain close to the ridge—beyond that, they are overlain by large-scale regional flows that appear to have originated from the direction of Athabasca Valles. In the southeast, there is evidence of contemporaneity between vent-sourced activity and large-scale plains-forming flow that was not sourced from the vents, indicating that activity here was part of a broader process of Cerberus plains formation from multiple sources. Crater counts show all the activity to be Late Amazonian, with the latest activity tentatively dating to circa 11 Ma. Thus, this study implies that very recent outflows from these vents contributed to the formation of the Cerberus plains and constrains the timing and local flow direction of plains-forming deposits from other sources.
Nogueira, Patricia; Gambi, Maria Cristina; Vizzini, Salvatrice; Califano, Gianmaria; Tavares, Ana Mafalda; Santos, Rui; Martínez-Crego, Begoña
2017-06-01
Ocean acidification (OA) predicted for 2100 is expected to shift seagrass epiphyte communities towards the dominance of more tolerant non-calcifying taxa. However, little is known about the indirect effects of such changes on food provision to key seagrass consumers. We found that epiphyte communities of the seagrass Posidonia oceanica in two naturally acidified sites (i.e. north and south sides of a volcanic CO 2 vent) and in a control site away from the vent at the Ischia Island (NW Mediterranean Sea) significantly differed in composition and abundance. Such differences involved a higher abundance of non-calcareous crustose brown algae and a decline of calcifying polychaetes in both acidified sites. A lower epiphytic abundance of crustose coralline algae occurred only in the south side of the vents, thus suggesting that OA may alter epiphyte assemblages in different ways due to interaction with local factors such as differential fish herbivory or hydrodynamics. The OA effects on food items (seagrass, epiphytes, and algae) indirectly propagated into food provision to the sea urchin Paracentrotus lividus, as reflected by a reduced P. oceanica exploitation (i.e. less seagrass and calcareous epiphytes in the diet) in favour of non-calcareous green algae in both vent sites. In contrast, we detected no difference close and outside the vents neither in the composition of sea urchin diet nor in the total abundance of calcareous versus non-calcareous taxa. More research, under realistic scenarios of predicted pH reduction (i.e. ≤ 0.32 units of pH by 2100), is still necessary to better understand cascading effects of this altered urchin exploitation of food resources under acidified conditions on ecosystem diversity and function. Copyright © 2017 Elsevier Ltd. All rights reserved.
Zero Gravity Cryogenic Vent System Concepts for Upper Stages
NASA Technical Reports Server (NTRS)
Flachbart, Robin H.; Holt, James B.; Hastings, Leon J.
2001-01-01
The capability to vent in zero gravity without resettling is a technology need that involves practically all uses of sub-critical cryogenics in space, and would extend cryogenic orbital transfer vehicle capabilities. However, the lack of definition regarding liquid/ullage orientation coupled with the somewhat random nature of the thermal stratification and resulting pressure rise rates, lead to significant technical challenges. Typically a zero gravity vent concept, termed a thermodynamic vent system (TVS), consists of a tank mixer to destratify the propellant, combined with a Joule-Thomson (J-T) valve to extract thermal energy from the propellant. Marshall Space Flight Center's (MSFC's) Multipurpose Hydrogen Test Bed (MHTB) was used to test both spray-bar and axial jet TVS concepts. The axial jet system consists of a recirculation pump heat exchanger unit. The spray-bar system consists of a recirculation pump, a parallel flow concentric tube heat exchanger, and a spray-bar positioned close to the longitudinal axis of the tank. The operation of both concepts is similar. In the mixing mode, the recirculation pump withdraws liquid from the tank and sprays it into the tank liquid, ullage, and exposed tank surfaces. When energy extraction is required, a small portion of the recirculated liquid is passed sequentially through the J-T expansion valve, the heat exchanger, and is vented overboard. The vented vapor cools the circulated bulk fluid, thereby removing thermal energy and reducing tank pressure. The pump operates alone, cycling on and off, to destratify the tank liquid and ullage until the liquid vapor pressure reaches the lower set point. At that point, the J-T valve begins to cycle on and off with the pump. Thus, for short duration missions, only the mixer may operate, thus minimizing or even eliminating boil-off losses.
Long-lived structural control of Mt. Shasta's plumbing system illuminated by 40Ar/39Ar geochronology
NASA Astrophysics Data System (ADS)
Calvert, A. T.; Christiansen, R. L.
2013-12-01
Mt. Shasta is the largest stratovolcano in the Cascade Arc, surpassed in volume only by the large rear-arc Medicine Lake and Newberry composite volcanoes. Including the material in the ~350 ka debris avalanche, it has produced more than 500 km3 of andesite and dacite from several superimposed central vents over its 700-850 kyr history. Earlier, between at least 970 to 1170 ka, the Rainbow Mountain volcano of similar composition and size occupied this latitude of the arc ~20 km further east. This shift of magmatic focus from within the arc axis (as defined by 6 Ma and younger calc-alkaline centers) to the arc front is poorly understood, but the current center's location appears structurally controlled. Most identifiable volcanic vents on Mt. Shasta lie within 1 km of a N-S line through the active summit cone. 40Ar/39Ar ages of map units occupying the vent alignment range from the Holocene (5×1 ka) current summit dome to at least the Middle Pleistocene (464×9 ka McKenzie Butte). The vast majority of eruptions have issued from central vents (Sargents Ridge, 300-135 ka; Misery Hill, 100-15 ka; and Hotlum, <10 ka), each 500 to 1000m north of its predecessor. A central vent for the pre-avalanche edifice is impossible to locate precisely, but was possibly on the same N-S trend and certainly no more than 4 km to the west, likely south of the Sargents Ridge central vent. ~15 of ~25 mapped flank vents lie on the alignment and the other ten lie west of the line. No identified volcanic vents lie east of the line until >12 km from Mt. Shasta (Ash Creek Butte, 227 ka; Basalt of McCloud River, 38 ka; The Whaleback, 102 ka), and monogenetic and polygenetic centers further east and northeast. From these observations we infer that: (1) magmas are localized along a ~20 km, long-lived, N-S trending structure running through the summit; (2) the upper crustal structure appears impermeable to magmas and resistant to dikes on its eastern side; (3) the western half of the area beneath the volcano appears substantially weaker, as dikes have fed flank vents 10-20 km from the summit over the history of the volcano; and (4) the orientation of the WNW-directed debris avalanche, coincident with the greatest concentration of flank vents, may indicate either structural weakness or failure following emplacement of a cryptodome similar to the 1980 events at Mt. St. Helens.
NASA Astrophysics Data System (ADS)
Fortunato, C. S.; Huber, J. A.
2015-12-01
The chemolithoautotrophic microbial community of the rocky subseafloor potentially provides a large amount of organic carbon to the deep ocean, yet our understanding of the activity and metabolic complexity of subseafloor organisms remains poorly described. Past studies have shown that the taxonomic structure of subseafloor communities differs based on the geochemical signatures of individual vents. In this study, we expanded beyond phylogeny and used a combination of metagenomic, metatranscriptomic, and RNA-based stable isotope probing (RNA-SIP) analyses to identify the metabolic potential, expression patterns, and the active autotrophic players and genomic pathways present in venting fluids from Axial Seamount, an active submarine volcano off the coast of Oregon, USA. Low-temperature diffuse vent fluids from three hydrothermal vents, Marker 113, Marker 33, and Anemone, were filtered and preserved on the seafloor for metagenome and metatranscriptome analyses. Fluid for RNA-SIP was also collected and incubated shipboard with 13C-labeled sodium bicarbonate at 30ºC, 55ºC, and 80ºC for each vent. Taxonomically, Epsilonproteobacteria comprised a significant proportion of the community at all three vents, but each vent also had distinct groups that were abundant including SUP05 at Anemone and Methanococcus at Marker 113. Functionally, vents shared many metabolic processes including genes for denitrification, sulfur reduction and sulfur, hydrogen, and ammonium oxidation, which were present and expressed in similar abundance across all three vents. One metabolic difference between vents was the presence and expression of genes for methanogenesis, which were highly abundant and expressed at Marker 113, in lower abundance and expression at Marker 33, and not present at Anemone. RNA-SIP analysis is ongoing but initial results from Marker 113 revealed that at mesophilic, thermophilic, or hyperthemophilic temperatures, different genera and autotrophic metabolisms dominated. In addition, RNA-SIP showed that at 80ºC a different hyperthermophilic group dominated at each vent. Overall, this study demonstrates the metabolic and taxonomic diversity of the subseafloor and better characterizes the subseafloor chemolithoautotrophs and their role in biogeochemical cycling.
Tectonic controls on the genesis of ignimbrites from the Campanian Volcanic Zone, southern Italy
Rolandi, G.; Bellucci, F.; Heizler, M.T.; Belkin, H.E.; de Vivo, B.
2003-01-01
The Campanian Plain is an 80 x 30 km region of southern Italy, bordered by the Apennine Chain, that has experienced subsidence during the Quaternary. This region, volcanologically active in the last 600 ka, has been identified as the Campanian Volcanic Zone (CVZ). The products of three periods of trachytic ignimbrite volcanism (289-246 ka, 157 ka and 106 ka) have been identified in the Apennine area in the last 300 ka. These deposits probably represent distal ash flow units of ignimbrite eruptions which occurred throughout the CVZ. The resulting deposits are interstratified with marine sediments indicating that periods of repeated volcano-tectonic emergence and subsidence may have occurred in the past. The eruption, defined as the Campanian Ignimbrite (CI), with the largest volume (310 km3), occurred in the CVZ 39 ka ago. The products of the CI eruption consist of two units (unit-1 and unit-2) formed from a single compositionally zoned magma body. Slightly different in composition, three trachytic melts constitute the two units. Unit-1 type A is an acid trachyte, type B is a trachyte and type C of unit-2 is a mafic trachyte. The CI, vented from pre-existing neotectonic faults, formed during the Apennine uplift, Initially the venting of volatile-rich type A magma deposited the products to the N-NE of the CVZ. During the eruption, the Acerra graben already affected by a NE-SW fault system, was transected by E-W faults, forming a cross-graben that extended to the gulf of Naples. E-W faults were then further dislocated by NE-SW transcurrent movements. This additional collapse significantly influenced the deposition of the B-type magma of unit-1, and the C-type magma of unit-2 toward the E-SE and S, in the Bay of Naples. The pumice fall deposit underlying the CI deposits, until now thought to be associated with the CI eruption, is not a strict transition from plinian to CI-forming activity. It is derived instead from an independent source probably located near the Naples area. This initial volcanic activity is assumed to be a precursor to the CI trachytic eruptions, which vented along regional faults.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT FUEL VENTING AND EXHAUST EMISSION REQUIREMENTS FOR TURBINE ENGINE POWERED AIRPLANES Exhaust Emissions (In-use Aircraft Gas... aircraft gas turbine engines certificated for operation within the United States of the classes specified...
Code of Federal Regulations, 2011 CFR
2011-01-01
... Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT FUEL VENTING AND EXHAUST EMISSION REQUIREMENTS FOR TURBINE ENGINE POWERED AIRPLANES Exhaust Emissions (In-use Aircraft Gas... aircraft gas turbine engines certificated for operation within the United States of the classes specified...
Mammoth Mountain and its mafic periphery—A late Quaternary volcanic field in eastern California
Hildreth, Wes; Fierstein, Judith; Champion, Duane E.; Calvert, Andrew T.
2014-01-01
The trachydacite complex of Mammoth Mountain and an array of contemporaneous mafic volcanoes in its periphery together form a discrete late Pleistocene magmatic system that is thermally and compositionally independent of the adjacent subalkaline Long Valley system (California, USA). The Mammoth system first erupted ca. 230 ka, last erupted ca. 8 ka, and remains restless and potentially active. Magmas of the Mammoth system extruded through Mesozoic plutonic rocks of the Sierra Nevada batholith and extensive remnants of its prebatholith wall rocks. All of the many mafic and silicic vents of the Mammoth system are west or southwest of the structural boundary of Long Valley caldera; none is inboard of the caldera’s buried ring-fault zone, and only one Mammoth-related vent is within the zone. Mammoth Mountain has sometimes been called part of the Inyo volcanic chain, an ascription we regard inappropriate and misleading. The scattered vent array of the Mammoth system, 10 × 20 km wide, is unrelated to the range-front fault zone, and its broad nonlinear footprint ignores both Long Valley caldera and the younger Mono-Inyo range-front vent alignment. Moreover, the Mammoth Mountain dome complex (63%–71% SiO2; 8.0%–10.5% alkalies) ended its period of eruptive activity (100–50 ka) long before Holocene inception of Inyo volcanism. Here we describe 25 silicic eruptive units that built Mammoth Mountain and 37 peripheral units, which include 13 basalts, 15 mafic andesites, 6 andesites, and 3 dacites. Chemical data are appended for nearly 900 samples, as are paleomagnetic data for ∼150 sites drilled. The 40Ar/39Ar dates (230–16 ka) are given for most units, and all exposed units are younger than ca. 190 ka. Nearly all are mildly alkaline, in contrast to the voluminous subalkaline rhyolites of the contiguous long-lived Long Valley magma system. Glaciated remnants of Neogene mafic and trachydacitic lavas (9.1–2.6 Ma) are scattered near Mammoth Mountain, but Quaternary equivalents older than ca. 230 ka are absent. The wide area of late Quaternary Mammoth magmatism remained amagmatic during the long interval (2.2–0.3 Ma) of nearby Long Valley rhyolitic eruptions.
NASA Astrophysics Data System (ADS)
Fontana, G.; Mac Niocaill, C.; Brown, R.; Sparks, R. S.; Matthew, F.; Gernon, T. M.
2009-12-01
Kimberlites are complex, ultramafic and diamond-bearing volcanic rocks preserved in volcanic pipes, dykes and craters. The formation of kimberlite pipes is a strongly debated issue and two principal theories have been proposed to explain pipe formation: (1) the explosive degassing of magma, and (2) the interaction of rising magma with groundwater (phreatomagmatism). Progressive thermal demagnetization studies are a powerful tool for determining the emplacement temperatures of ancient volcanic deposits and we present the first application of such techniques to kimberlite deposits. Lithic clasts were sampled from a variety of lithofacies, from three pipes for which the internal geology is well constrained (A/K1 pipe, Orapa Mine, Botswana and the K1 and K2 pipes, Venetia Mine, South Africa). The sampled deposits included massive and layered vent-filling breccias with varying abundances of lithic inclusions and layered crater-filling pyroclastic deposits, talus breccias and volcaniclastic breccias. Lithic clasts sampled from layered and massive vent-filling pyroclastic deposits in A/K1 were emplaced at >590° C. Results from K1 and K2 provide a maximum emplacement temperature limit for vent-filling breccias of 420-460° C; and constrain equilibrium deposit temperatures at 300-340° C. Crater-filling volcaniclastic kimberlite breccias and talus deposits from A/K1 were emplaced at ambient temperatures, consistent with infilling of the pipe by post-eruption epiclastic processes. Identified within the epiclastic crater-fill succession is a laterally extensive 15-20 metre thick kimberlite pyroclastic flow deposit emplaced at temperatures of 220-440° C. It overlies the post-eruption epiclastic units and is considered an extraneous pyroclastic kimberlite deposit erupted from another kimberlite vent. The results provide important constraints on kimberlite emplacement mechanisms and eruption dynamics. Emplacement temperatures of >590°C for pipe-filling pyroclastic deposits are consistent with volatile-driven eruptions, and suggest phreatomagmatism did not play a major role in the generation of the deposits. The discovery of an extraneous pyroclastic flow deposit within the Orapa A/K1 epiclastic crater, which was erupted from another vent, suggests kimberlite eruptions are capable of producing sustained eruption columns and thick pyroclastic deposits involving significant transport away from source.
40 CFR 65.107 - Standards: Pumps in light liquid service.
Code of Federal Regulations, 2011 CFR
2011-07-01
... or fuel gas system or connected by a closed vent system to a control device that complies with the requirements of § 65.115; or (C) Equipped with a closed-loop system that purges the barrier fluid into a... section. (3) Routed to a process or fuel gas system or equipped with a closed vent system. Any pump that...
DOE Office of Scientific and Technical Information (OSTI.GOV)
2016-02-01
This document addresses the use of passive vents as a source of outdoor air in multifamily buildings. The challenges associated with implementing passive vents and the factors affecting performance are outlined. A comprehensive design methodology and quantified performance metrics are provided. Two hypothetical design examples are provided to illustrate the process. This document is intended to be useful to designers, decision-makers, and contractors implementing passive ventilation strategies. It is also intended to be a resource for those responsible for setting high-performance building program requirements, especially pertaining to ventilation and outdoor air. To ensure good indoor air quality, a dedicated sourcemore » of outdoor air is an integral part of high-performance buildings. Presently, there is a lack of guidance pertaining to the design and installation of passive vents, resulting in poor system performance. This report details the criteria necessary for designing, constructing, and testing passive vent systems to enable them to provide consistent and reliable levels of ventilation air from outdoors.« less
Experimental study of geysers through a vent pipe connected to flowing sewers.
Huang, Biao; Wu, Shiqiang; Zhu, David Z; Schulz, Harry E
2017-04-01
Geysers of air-water mixtures in urban drainage systems is receiving considerable attention due to public safety concerns. However, the geyser formation process and its relation with air release from pressurized pipes are still relatively little known. A large-scale physical model, that consisted of a main tunnel with a diameter of 270 mm and a length of 25 m connecting two reservoirs and a vertical vent pipe, was established to investigate geyser evolution and pressure transients. Experimental results including dynamic pressure data and high speed videos were analysed in order to characterize geysering flow through the vent pipe. Pressure transients were observed during geysering events. Their amplitudes were found to be about three times the driving pressure head and their periods were close to the classic surge tank predictions. The influence of flow rate and vent pipe size were examined: geyser heights and pressure peaks decreased for small flow rate and large diameter vent pipe. It is suggested that geyser heights are related with the pressure head and the density of the air-water mixture.
LOX Tank Helium Removal for Propellant Scavenging
NASA Technical Reports Server (NTRS)
Chato, David J.
2009-01-01
System studies have shown a significant advantage to reusing the hydrogen and oxygen left in these tanks after landing on the Moon in fuel cells to generate power and water for surface systems. However in the current lander concepts, the helium used to pressurize the oxygen tank can substantially degrade fuel cell power and water output by covering the reacting surface with inert gas. This presentation documents an experimental investigation of methods to remove the helium pressurant while minimizing the amount of the oxygen lost. This investigation demonstrated that significant quantities of Helium (greater than 90% mole fraction) remain in the tank after draining. Although a single vent cycle reduced the helium quantity, large amounts of helium remained. Cyclic venting appeared to be more effective. Three vent cycles were sufficient to reduce the helium to small (less than 0.2%) quantities. Two vent cycles may be sufficient since once the tank has been brought up to pressure after the second vent cycle the helium concentration has been reduced to the less than 0.2% level. The re-pressurization process seemed to contribute to diluting helium. This is as expected since in order to raise the pressure liquid oxygen must be evaporated. Estimated liquid oxygen loss is on the order of 82 pounds (assuming the third vent cycle is not required).
Monitoring biodegradation of diesel fuel in bioventing processes using in situ respiration rate.
Lee, T H; Byun, I G; Kim, Y O; Hwang, I S; Park, T J
2006-01-01
An in situ measuring system of respiration rate was applied for monitoring biodegradation of diesel fuel in a bioventing process for bioremediation of diesel contaminated soil. Two laboratory-scale soil columns were packed with 5 kg of soil that was artificially contaminated by diesel fuel as final TPH (total petroleum hydrocarbon) concentration of 8,000 mg/kg soil. Nutrient was added to make a relative concentration of C:N:P = 100:10:1. One soil column was operated with continuous venting mode, and the other one with intermittent (6 h venting/6 h rest) venting mode. On-line O2 and CO2 gas measuring system was applied to measure O2 utilisation and CO2 production during biodegradation of diesel for 5 months. Biodegradation rate of TPH was calculated from respiration rate measured by the on-line gas measuring system. There were no apparent differences between calculated biodegradation rates from two columns with different venting modes. The variation of biodegradation rates corresponded well with trend of the remaining TPH concentrations comparing other biodegradation indicators, such as C17/pristane and C18/phytane ratio, dehydrogenase activity, and the ratio of hydrocarbon utilising bacteria to total heterotrophic bacteria. These results suggested that the on-line measuring system of respiration rate would be applied to monitoring biodegradation rate and to determine the potential applicability of bioventing process for bioremediation of oil contaminated soil.
High-Resolution Geologic Mapping in the Eastern Manus Basin
NASA Astrophysics Data System (ADS)
Thal, J.; Bach, W.; Tivey, M.; Yoerger, D. R.
2011-12-01
AUV-based microbathymetry combined with ROV video data was used to create the first high-resolution geologic maps of two hydrothermal active areas in the eastern Manus Basin: North Su volcano and PACManus hydrothermal field on Pual Ridge. The data were recorded in 2006 and 2011 during the research cruises Magellan-06 operated by the Woods Hole Oceanographic Institution and BAMBUS (SO-216) operated by MARUM / University Bremen. High accuracy underwater navigation transponder-based and Posidonia systems allowed us to combine video data with bathymetry. The navigation on both cruises was very precise (m-scale) and navigation offsets were less than 10 m. We conducted detailed geologic mapping and sampling to identify the seafloor volcanic and hydrothermal features and created highly detailed maps that provide a comprehensive picture of the seafloor and vent distribution in the eastern Manus Basin. Several different types of dacite lava morphology were mapped, including pillow lava, lobate flows and massive block lava. We have compiled all available information on rock chemistry, fluid and temperature measurements, video data, bathymetry and navigation data into a GIS database. We find that, in contrast to the tectonic control on vent distribution at slow spreading mid-ocean ridges, the pathways of upwelling hydrothermal vent fluids at PACManus are dominated by volcanic features, such as lava domes and thick, massive block lava flows. Vent fields are developed preferentially along the margins of major flow units, probably because the cores of these units are impermeable to fluid flow, while the autobrecciated outer parts of the flows are not. In the North Su area, a comparison of seafloor maps from 2006 and 2011 reveals recent volcanic activity, which has strongly modified the bathymetry and hydrothermal vent distribution on the southern flank of the volcano. An ash cone with multiple small craters on the SW flank of the North-Su volcano that didn't exist in 2006 was mapped in 2011. Also, magmatic degassing was much more vigorous in 2011, with large accumulations of liquid sulfur (from disproportionation of magmatic SO2) as well as extensive bubbling of supercritical and liquid CO2.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Nonhalogenated Flare 0.5276 0.0998 −2.096×10−3 −2.000×10−4 Thermal Incinerator 0 Percent Heat Recovery 0.4068 0.0171 8.664×10−3 −3.162×10−4 Thermal Incinerator 70 Percent Heat Recovery 0.6868 3.209×10−3 3.546×10−3 1... Process Vents, Storage Vessels, Transfer Operations, and Wastewater Pt. 63, Subpt. G, Table 2 Table 2 to...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Coefficients a b c d Nonhalogenated Flare 1.935 3.660×10−1 −7.687×10−3 −7.333×10−4 Thermal Incinerator 0 Percent Heat Recovery 1.492 6.267×10−2 3.177×10−2 −1.159×10−3 Thermal Incinerator 70 Percent Heat Recovery... for Process Vents, Storage Vessels, Transfer Operations, and Wastewater Pt. 63, Subpt. G, Table 1...
DUCKS: Low cost thermal monitoring units for near-vent deployment
Harris, A.; Pirie, D.; Horton, K.; Garbeil, H.; Pilger, E.; Ramm, H.; Hoblitt, R.; Thornber, C.; Ripepe, M.; Marchetti, E.; Poggi, P.
2005-01-01
During 1999 we designed and tested a thermal monitoring system to provide a cheap, robust, modular, real-time system capable of surviving the hostile conditions encountered proximal to active volcanic vents. In November 2000 the first system was deployed at Pu'u 'O'o (Kilauea, Hawai'i) to target persistently active vents. Aside from some minor problems, such as sensor damage due to tampering, this system remained operational until January 2004. The success of the prototype system led us to use the blueprint for a second installation at Stromboli (Aeolian Islands, Italy). This was deployed, dug into a bomb-proof bunker, during May 2002 and survived the April 2003 paroxysmal eruption despite being located just 250 m from the vent. In both cases, careful waterproofing of connectors and selection of suitable protection has prevented water damage and corrosion in the harsh atmosphere encountered at the crater rim. The Pu'u 'O'o system cost ???US$10,000 and comprises four modules: sensors, transmission and power hub, repeater station and reception site. The sensor component consists of three thermal infrared thermometers housed in Pelican??? cases fitted with Germanium-Arsenide-Selenium windows. Two 1?? field of view (FOV) sensors allow specific vents to be targeted and a 60?? FOV sensor provides a crater floor overview. A hard wire connection links to a Pelican???-case-housed microprocessor, modem and power module. From here data are transmitted, via a repeater site, to a dedicated PC at the Hawaiian Volcano Observatory. Here data are displayed with a delay of ???3 s between acquisition and display. The modular design allows for great flexibility. At Stromboli, 1?? and 15?? FOV sensor modules can be switched depending changes in activity style and crater geometry. In addition a direct line of site to the Stromboli reception center negates the repeater site requirement, reducing the cost to US$5500 for a single sensor system. We have also constructed self-contained units w ith internal data loggers for US$1500/unit. These have been tested at Kilauea, Stromboli, Etna, Masaya, Santiaguito, Fuego, Pacaya, Poas, Soufriere Hills, Villarrica and Erta Ale. These instruments have proved capable of detecting thermal signals associated with: (1) gas emission; (2) gas jetting events; (3) crater floor collapse; (4) lava effusion; (5) lava flow in tubes; (6) lava lake activity; (7) lava dome activity; and (8) crater lake skin temperature. ?? 2005 Elsevier B.V. All rights reserved.
DUCKS: Low cost thermal monitoring units for near-vent deployment
NASA Astrophysics Data System (ADS)
Harris, Andrew; Pirie, Dawn; Horton, Keith; Garbeil, Harold; Pilger, Eric; Ramm, Hans; Hoblitt, Rick; Thornber, Carl; Ripepe, Maurizio; Marchetti, Emanuele; Poggi, Pasquale
2005-05-01
During 1999 we designed and tested a thermal monitoring system to provide a cheap, robust, modular, real-time system capable of surviving the hostile conditions encountered proximal to active volcanic vents. In November 2000 the first system was deployed at Pu'u 'O'o (Kilauea, Hawai'i) to target persistently active vents. Aside from some minor problems, such as sensor damage due to tampering, this system remained operational until January 2004. The success of the prototype system led us to use the blueprint for a second installation at Stromboli (Aeolian Islands, Italy). This was deployed, dug into a bomb-proof bunker, during May 2002 and survived the April 2003 paroxysmal eruption despite being located just 250 m from the vent. In both cases, careful waterproofing of connectors and selection of suitable protection has prevented water damage and corrosion in the harsh atmosphere encountered at the crater rim. The Pu'u 'O'o system cost ˜US10,000 and comprises four modules: sensors, transmission and power hub, repeater station and reception site. The sensor component consists of three thermal infrared thermometers housed in Pelican™ cases fitted with Germanium-Arsenide-Selenium windows. Two 1° field of view (FOV) sensors allow specific vents to be targeted and a 60° FOV sensor provides a crater floor overview. A hard wire connection links to a Pelican™-case-housed microprocessor, modem and power module. From here data are transmitted, via a repeater site, to a dedicated PC at the Hawaiian Volcano Observatory. Here data are displayed with a delay of ˜3 s between acquisition and display. The modular design allows for great flexibility. At Stromboli, 1° and 15° FOV sensor modules can be switched depending changes in activity style and crater geometry. In addition a direct line of site to the Stromboli reception center negates the repeater site requirement, reducing the cost to US5500 for a single sensor system. We have also constructed self-contained units with internal data loggers for US$1500/unit. These have been tested at Kilauea, Stromboli, Etna, Masaya, Santiaguito, Fuego, Pacaya, Poas, Soufriere Hills, Villarrica and Erta Ale. These instruments have proved capable of detecting thermal signals associated with: (1) gas emission; (2) gas jetting events; (3) crater floor collapse; (4) lava effusion; (5) lava flow in tubes; (6) lava lake activity; (7) lava dome activity; and (8) crater lake skin temperature.
NASA Astrophysics Data System (ADS)
Coogan, L. A.; Attar, A.; Mihaly, S. F.; Jeffries, M.; Pope, M.
2017-04-01
The Endeavour segment of the Juan de Fuca mid-ocean ridge is one of the best studied ridge segments and has recently been instrumented as part of Ocean Networks Canada's NEPTUNE cabled observatory. Here we investigate the interaction between high-temperature vent fluids and the overlying water column. A new tow-yo survey found that the average temperature anomaly in the neutrally buoyant plume was ˜0.043°C. The water column temperature and light attenuation anomalies correlate linearly in some areas of the plume but in other areas there is a low light attenuation anomaly relative to the temperature anomaly. This temperature excess is interpreted to reflect heat input through (particle-poor) diffuse flow. If this is correct, about half of the heat flux along the Endeavour segment comes from diffuse flow. Sediment trap and push core data show that the mass accumulation rate of the hydrothermal component of the sediments decreases rapidly with distance from the major vent fields. Large changes in the composition of the hydrothermal component of the sediments also occur with distance from the vent fields. The composition of the sediments indicates (i) sulfides precipitate early and accumulate most rapidly close to the vents with a preferential order of element removal from the plume of Cd > Ag > Cu > Co ˜ Fe; (ii) barite is deposited somewhat further from the vents. Strontium and Pb appear to be strongly incorporated in barite and/or other sulfate minerals; (iii) at most a few percent of the mass of these "insoluble" elements that is vented gets deposited within 1.5 km of the vents.
2010-01-01
Background Bathymodiolus azoricus is a deep-sea hydrothermal vent mussel found in association with large faunal communities living in chemosynthetic environments at the bottom of the sea floor near the Azores Islands. Investigation of the exceptional physiological reactions that vent mussels have adopted in their habitat, including responses to environmental microbes, remains a difficult challenge for deep-sea biologists. In an attempt to reveal genes potentially involved in the deep-sea mussel innate immunity we carried out a high-throughput sequence analysis of freshly collected B. azoricus transcriptome using gills tissues as the primary source of immune transcripts given its strategic role in filtering the surrounding waterborne potentially infectious microorganisms. Additionally, a substantial EST data set was produced and from which a comprehensive collection of genes coding for putative proteins was organized in a dedicated database, "DeepSeaVent" the first deep-sea vent animal transcriptome database based on the 454 pyrosequencing technology. Results A normalized cDNA library from gills tissue was sequenced in a full 454 GS-FLX run, producing 778,996 sequencing reads. Assembly of the high quality reads resulted in 75,407 contigs of which 3,071 were singletons. A total of 39,425 transcripts were conceptually translated into amino-sequences of which 22,023 matched known proteins in the NCBI non-redundant protein database, 15,839 revealed conserved protein domains through InterPro functional classification and 9,584 were assigned with Gene Ontology terms. Queries conducted within the database enabled the identification of genes putatively involved in immune and inflammatory reactions which had not been previously evidenced in the vent mussel. Their physical counterpart was confirmed by semi-quantitative quantitative Reverse-Transcription-Polymerase Chain Reactions (RT-PCR) and their RNA transcription level by quantitative PCR (qPCR) experiments. Conclusions We have established the first tissue transcriptional analysis of a deep-sea hydrothermal vent animal and generated a searchable catalog of genes that provides a direct method of identifying and retrieving vast numbers of novel coding sequences which can be applied in gene expression profiling experiments from a non-conventional model organism. This provides the most comprehensive sequence resource for identifying novel genes currently available for a deep-sea vent organism, in particular, genes putatively involved in immune and inflammatory reactions in vent mussels. The characterization of the B. azoricus transcriptome will facilitate research into biological processes underlying physiological adaptations to hydrothermal vent environments and will provide a basis for expanding our understanding of genes putatively involved in adaptations processes during post-capture long term acclimatization experiments, at "sea-level" conditions, using B. azoricus as a model organism. PMID:20937131
Code of Federal Regulations, 2010 CFR
2010-07-01
... Inorganic HAP Emissions From Catalytic Reforming Units As stated in § 63.1567(b)(1), you shall meet each requirement in the following table that applies to you. If you use this type of control device for your vent . . . You shall install and operate this type of continuous monitoring system . . . 1. Wet scrubber...
The Origin of Ina: Evidence for Inflated Lava Flows on the Moon
NASA Technical Reports Server (NTRS)
Garry, W. B.; Robinson, M. S.; Zimbelman, J. R.; Bleacher, J. E.; Hawke, B. R.; Crumpler, L. S.; Braden, S. E.; Sato, H.
2012-01-01
Ina is an enigmatic volcanic feature on the Moon known for its irregularly shaped mounds, the origin of which has been debated since the Apollo Missions. Three main units are observed on the floor of the depression (2.9 km across, < or =64 m deep) located at the summit of a low-shield volcano: irregularly shaped mounds up to 20 m tall, a lower unit 1 to 5 m in relief that surrounds the mounds, and blocky material. Analyses of Lunar Reconnaissance Orbiter Camera images and topography show that features in Ina are morphologically similar to terrestrial inflated lava flows. Comparison of these unusual lunar mounds and possible terrestrial analogs leads us to hypothesize that features in Ina were formed through lava flow inflation processes. While the source of the lava remains unclear, this new model suggests that as the mounds inflated, breakouts along their margins served as sources for surface flows that created the lower morphologic unit. Over time, mass wasting of both morphologic units has exposed fresh surfaces observed in the blocky unit. Ina is different than the terrestrial analogs presented in this study in that the lunar features formed within a depression, no vent sources are observed, and no cracks are observed on the mounds. However, lava flow inflation processes explain many of the morphologic relationships observed in Ina and are proposed to be analogous with inflated lava flows on Earth.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-19
..., 2011. In addition to the anti-entrapment devices or systems, each public pool and spa in the United... release system; suction-limiting vent system; gravity drainage system; automatic pump shut-off system or...
Code of Federal Regulations, 2013 CFR
2013-07-01
... performance evaluation or test for a semi-regenerative catalytic reforming unit catalyst regenerator vent, you... properties. Examples of analytical methods include, but are not limited to: (i) Use of material balances...
Code of Federal Regulations, 2014 CFR
2014-07-01
... performance evaluation or test for a semi-regenerative catalytic reforming unit catalyst regenerator vent, you... properties. Examples of analytical methods include, but are not limited to: (i) Use of material balances...
Code of Federal Regulations, 2012 CFR
2012-07-01
... performance evaluation or test for a semi-regenerative catalytic reforming unit catalyst regenerator vent, you... properties. Examples of analytical methods include, but are not limited to: (i) Use of material balances...
Continuing Evolution of the Hydrothermal System at the RIDGE2000 ISS, 9-10° N EPR: 1991-2004
NASA Astrophysics Data System (ADS)
von Damm, K. L.; Parker, C. M.; Beers, K. A.; Hyde, A. A.
2004-12-01
We have been studying the evolution of the chemical composition of the mid-ocean ridge (MOR) hydrothermal system on the East Pacific Rise from 9° 46-51'N since it was impacted by volcanic eruptions in 1991/2. We have been using the chemical and temperature data to infer the processes that are occurring subseafloor in the upper oceanic crust. As of March 2004, the chemical compositions of the vent fluids from this site have not yet stabilized. This observation is helping us to better understand not only the impact of magmatic events on these systems, but also the time scales on which they occur. Centered at the RIDGE2000 ISS "bull's-eye" at 9° 50'N we have noted a striking increase in the number of hydrothermal vents as well as in their measured fluid temperatures beginning after ~2000. In November 2003 we first noted the formation of a black smoker vent at the Tica site (measured T=342° C). In March 2004 we identified another new area of robust flow near the Bio9 vents at 9° 50'N, the 'Alvinellid Mat,' that we anticipate will form an additional black smoker to the three currently active at this site. In March 2004 we measured temperatures of 388° C in fluids from both the Bio9 and Bio9' smokers, putting them essentially on the two phase curve for seawater at this depth. For all of the Bio9 vents, as well as Tica, the fluids contain less than 300 mmoles/kg of Cl, approximately half the local seawater concentration. These high temperature and low Cl concentrations are accompanied by unusually low Si concentrations, <9.5 mmoles/kg. These data suggest a relatively shallow depth of reaction for the fluids, within a few hundred meters of the seafloor. These are the hottest temperatures measured in the Bio9 vents since the eruption in 1992. In contrast, the temperatures at P vent, about 60m south have cooled by ˜15° C since 2002. About 400m south, the chlorinity of the fluids from Ty and Io vents have increased, and Tube Worm Pillar, about 400m further south has become inactive. Therefore the changes in the vent fluids vary widely and often in opposite senses, over ˜1.5km of very hydrothermally active ridge. A more complete discussion of the changes and our interpretation of their implications for processes occurring subseafloor will be presented.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 15 2010-07-01 2010-07-01 false Standards: Closed vent systems and control devices; or emissions routed to a fuel gas system or process. 65.115 Section 65.115 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Equipment Leaks § 65.115 Standards:...
Code of Federal Regulations, 2012 CFR
2012-07-01
... collected—PR. d,e Carbon Adsorber f a. Total regeneration steam flow or nitrogen flow, or pressure (gauge or absolute) during carbon bed regeneration cycle(s), and 1. Record the total regeneration steam flow or nitrogen flow, or pressure for each carbon bed regeneration cycle.2. Record and report the total...
Code of Federal Regulations, 2012 CFR
2012-07-01
... collected—PR. d,e Carbon adsorber f a. Total regeneration steam flow or nitrogen flow, or pressure gauge or absolute) during carbon bed regeneration cycle(s), and 1. Record of total regeneration steam flow or nitrogen flow, or pressure for each carbon bed regeneration cycle. 2. Record and report the total...
Code of Federal Regulations, 2011 CFR
2011-07-01
... collected—PR. d,e Carbon adsorber f a. Total regeneration steam flow or nitrogen flow, or pressure gauge or absolute) during carbon bed regeneration cycle(s), and 1. Record of total regeneration steam flow or nitrogen flow, or pressure for each carbon bed regeneration cycle. 2. Record and report the total...
Code of Federal Regulations, 2010 CFR
2010-07-01
... collected—PR. d,e Carbon Adsorber f a. Total regeneration steam flow or nitrogen flow, or pressure (gauge or absolute) during carbon bed regeneration cycle(s), and 1. Record the total regeneration steam flow or nitrogen flow, or pressure for each carbon bed regeneration cycle.2. Record and report the total...
Code of Federal Regulations, 2013 CFR
2013-07-01
... collected—PR. d,e Carbon adsorber f a. Total regeneration steam flow or nitrogen flow, or pressure gauge or absolute) during carbon bed regeneration cycle(s), and 1. Record of total regeneration steam flow or nitrogen flow, or pressure for each carbon bed regeneration cycle. 2. Record and report the total...
Code of Federal Regulations, 2010 CFR
2010-07-01
... collected—PR. d,e Carbon adsorber f a. Total regeneration steam flow or nitrogen flow, or pressure gauge or absolute) during carbon bed regeneration cycle(s), and 1. Record of total regeneration steam flow or nitrogen flow, or pressure for each carbon bed regeneration cycle. 2. Record and report the total...
Code of Federal Regulations, 2013 CFR
2013-07-01
... collected—PR. d,e Carbon Adsorber f a. Total regeneration steam flow or nitrogen flow, or pressure (gauge or absolute) during carbon bed regeneration cycle(s), and 1. Record the total regeneration steam flow or nitrogen flow, or pressure for each carbon bed regeneration cycle.2. Record and report the total...
Code of Federal Regulations, 2011 CFR
2011-07-01
... collected—PR. d,e Carbon Adsorber f a. Total regeneration steam flow or nitrogen flow, or pressure (gauge or absolute) during carbon bed regeneration cycle(s), and 1. Record the total regeneration steam flow or nitrogen flow, or pressure for each carbon bed regeneration cycle.2. Record and report the total...
Code of Federal Regulations, 2014 CFR
2014-07-01
... collected—PR. d e Carbon adsorber f a. Total regeneration steam flow or nitrogen flow, or pressure gauge or absolute) during carbon bed regeneration cycle(s), and 1. Record of total regeneration steam flow or nitrogen flow, or pressure for each carbon bed regeneration cycle. 2. Record and report the total...
Code of Federal Regulations, 2014 CFR
2014-07-01
... collected—PR. d e Carbon Adsorber f a. Total regeneration steam flow or nitrogen flow, or pressure (gauge or absolute) during carbon bed regeneration cycle(s), and 1. Record the total regeneration steam flow or nitrogen flow, or pressure for each carbon bed regeneration cycle.2. Record and report the total...
40 CFR 63.1026 - Pumps in light liquid service standards.
Code of Federal Regulations, 2011 CFR
2011-07-01
... or fuel gas system or connected by a closed-vent system to a control device that complies with the requirements of either § 63.1034 or § 63.1021(b) of this part; or (C) Equipped with a closed-loop system that... paragraph (b) of this section. (3) Routed to a process or fuel gas system or equipped with a closed vent...
STS-84 oxygen generator for Mir on display at SPACEHAB
NASA Technical Reports Server (NTRS)
1997-01-01
An oxygen generator destined to replace a malfunctioning unit on the Russian Mir Space Station is the object of much curiosity during preflight preparations in the SPACEHAB Payload Processing Facility. A SPACEHAB Double Module on the Space Shuttle Atlantis will carry the oxygen generator to Mir during STS-84, the sixth Shuttle-Mir docking. The nearly 300-pound generator, manufactured by RSC Energia in Russia, will replace one of two Mir units that have been malfunctioning recently. The generator functions by electrolysis, which separates water into its oxygen and hydrogen components. The hydrogen is vented and the oxygen is used for breathing by the Mir crew. The generator is 4.2 feet in length and 1.4 feet in diameter. STS-84, which is planned to include a Mir crew exchange of astronaut C. Michael Foale for Jerry M. Linenger, is targeted for a May 15 liftoff.
NASA Astrophysics Data System (ADS)
Lin, Saulwood; Tseng, Yi-Ting; Cheng, Wan-Yen; Chou, Cheng-Tien; Chen, NeiChen; Hsieh, I.-Chih
2016-04-01
TsanYao Mud Volcano (TYMV) is the largest mud volcano cone in the Hengchun Mud Volcano Group (HCMVG), located at the upper slope of the accrretionary wedge, southwest of Taiwan. The region is under active tectonic activity with the Philippine Plate, moving northwestward at a rate of ~8 cm/year. This region also receives huge quantity of suspended particle load of ~100 mT/year at present time from adjacent small rivers of the Island of Taiwan. Large loads of suspended sediments influx become a major source of organic carbon and later gas and other hydrocarbon. Gas and fluid in the mud volcano are actively venting from deep to the sea floor on the upper slope of the accretionary wedge. In order to understand venting on the HCMVG, echo sounder, towcam and coring were carried out. Pore water sulfate, chloride, potassium, calcium, stable isotope O-18, gas compositions, dissolved sulfide were analysed. The HCMVG consists of 12 volcano cones of different sizes. Large quantity of gas and fluid are venting directly from deep to the TYMV structure high, as well as 50+ other vents as appeared as flares on the echo sounder. Some flares are reaching to the atmosphere and likely a source of green house gases to the atmosphere. Venting fluids include gas bubbles, suspended particle, mud, and breccia. Breccia size could reach more than 12 cm in diameter. Circular bands in different color appeared around the cone may represent stages of vent eruptions. Compositions of vent gas include methane, ethane and propane. High proportions of ethane and propane in the vent gas demonstrated that source of gas are thermogenic in origin. Patchy authigenic carbonate, bacterial mats, bivalves, tube worms and other chemosynthesis organisms were supported by venting gas AOM process near the sea floor. Pore water chloride concentrations show distinct variation pattern from center cone to the side of the volcano, with low in the center and high away from the cone. Pore water with higher than seawater chloride indicated gas hydrate formation in sediments away from the mud volcano cone.
NASA Astrophysics Data System (ADS)
Iyer, Karthik; Schmid, Daniel W.; Planke, Sverre; Millett, John
2017-06-01
Vent structures are intimately associated with sill intrusions in sedimentary basins globally and are thought to have been formed contemporaneously due to overpressure generated by gas generation during thermogenic breakdown of kerogen or boiling of water. Methane and other gases generated during this process may have driven catastrophic climate change in the geological past. In this study, we present a 2D FEM/FVM model that accounts for 'explosive' vent formation by fracturing of the host rock based on a case study in the Harstad Basin, offshore Norway. Overpressure generated by gas release during kerogen breakdown in the sill thermal aureole causes fracture formation. Fluid focusing and overpressure migration towards the sill tips results in vent formation after only few tens of years. The size of the vent depends on the region of overpressure accessed by the sill tip. Overpressure migration occurs in self-propagating waves before dissipating at the surface. The amount of methane generated in the system depends on TOC content and also on the type of kerogen present in the host rock. Generated methane moves with the fluids and vents at the surface through a single, large vent structure at the main sill tip matching first-order observations. Violent degassing takes place within the first couple of hundred years and occurs in bursts corresponding to the timing of overpressure waves. The amount of methane vented through a single vent is only a fraction (between 5 and 16%) of the methane generated at depth. Upscaling to the Vøring and Møre Basins, which are a part of the North Atlantic Igneous Province, and using realistic host rock carbon content and kerogen values results in a smaller amount of methane vented than previously estimated for the PETM. Our study, therefore, suggests that the negative carbon isotope excursion (CIE) observed in the fossil record could not have been caused by intrusions within the Vøring and Møre Basins alone and that a contribution from other regions in the NAIP is also required to drive catastrophic climate change.
40 CFR 265.1064 - Recordkeeping requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... waste management units in one recordkeeping system if the system identifies each record by each...) Design documentation and monitoring, operating, and inspection information for each closed-vent system...) An up-to-date analysis and the supporting information and data used to determine whether or not...
40 CFR 63.1063 - Floating roof requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... opening except those for automatic bleeder vents (vacuum breaker vents) and rim space vents shall have its... vents (vacuum breaker vents), rim space vents, leg sleeves, and deck drains shall be equipped with a... automatic bleeder vent (vacuum breaker vent) and rim space vent shall be equipped with a gasketed lid...
40 CFR 63.1063 - Floating roof requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... opening except those for automatic bleeder vents (vacuum breaker vents) and rim space vents shall have its... vents (vacuum breaker vents), rim space vents, leg sleeves, and deck drains shall be equipped with a... automatic bleeder vent (vacuum breaker vent) and rim space vent shall be equipped with a gasketed lid...
40 CFR 63.1063 - Floating roof requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... opening except those for automatic bleeder vents (vacuum breaker vents) and rim space vents shall have its... vents (vacuum breaker vents), rim space vents, leg sleeves, and deck drains shall be equipped with a... automatic bleeder vent (vacuum breaker vent) and rim space vent shall be equipped with a gasketed lid...
40 CFR 63.1063 - Floating roof requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... opening except those for automatic bleeder vents (vacuum breaker vents) and rim space vents shall have its... vents (vacuum breaker vents), rim space vents, leg sleeves, and deck drains shall be equipped with a... automatic bleeder vent (vacuum breaker vent) and rim space vent shall be equipped with a gasketed lid...
Dick, Gregory J; Anantharaman, Karthik; Baker, Brett J; Li, Meng; Reed, Daniel C; Sheik, Cody S
2013-01-01
Hydrothermal plumes are an important yet understudied component of deep-sea vent microbial ecosystems. The significance of plume microbial processes can be appreciated from three perspectives: (1) mediation of plume biogeochemistry, (2) dispersal of seafloor hydrothermal vent microbes between vents sites, (3) as natural laboratories for understanding the ecology, physiology, and function of microbial groups that are distributed throughout the pelagic deep sea. Plume microbiology has been largely neglected in recent years, especially relative to the extensive research conducted on seafloor and subseafloor systems. Rapidly advancing technologies for investigating microbial communities provide new motivation and opportunities to characterize this important microbial habitat. Here we briefly highlight microbial contributions to plume and broader ocean (bio)geochemistry and review recent work to illustrate the ecological and biogeographic linkages between plumes, seafloor vent habitats, and other marine habitats such as oxygen minimum zones (OMZs), cold seeps, and oil spills. 16S rRNA gene surveys and metagenomic/-transcriptomic data from plumes point to dominant microbial populations, genes, and functions that are also operative in OMZs (SUP05, ammonia-oxidizing Archaea, and SAR324 Deltaproteobacteria) and hydrocarbon-rich environments (methanotrophs). Plume microbial communities are distinct from those on the seafloor or in the subsurface but contain some signatures of these habitats, consistent with the notion that plumes are potential vectors for dispersal of microorganisms between seafloor vent sites. Finally, we put forward three pressing questions for the future of deep-sea hydrothermal plume research and consider interactions between vents and oceans on global scales.
Dick, Gregory J.; Anantharaman, Karthik; Baker, Brett J.; Li, Meng; Reed, Daniel C.; Sheik, Cody S.
2013-01-01
Hydrothermal plumes are an important yet understudied component of deep-sea vent microbial ecosystems. The significance of plume microbial processes can be appreciated from three perspectives: (1) mediation of plume biogeochemistry, (2) dispersal of seafloor hydrothermal vent microbes between vents sites, (3) as natural laboratories for understanding the ecology, physiology, and function of microbial groups that are distributed throughout the pelagic deep sea. Plume microbiology has been largely neglected in recent years, especially relative to the extensive research conducted on seafloor and subseafloor systems. Rapidly advancing technologies for investigating microbial communities provide new motivation and opportunities to characterize this important microbial habitat. Here we briefly highlight microbial contributions to plume and broader ocean (bio)geochemistry and review recent work to illustrate the ecological and biogeographic linkages between plumes, seafloor vent habitats, and other marine habitats such as oxygen minimum zones (OMZs), cold seeps, and oil spills. 16S rRNA gene surveys and metagenomic/-transcriptomic data from plumes point to dominant microbial populations, genes, and functions that are also operative in OMZs (SUP05, ammonia-oxidizing Archaea, and SAR324 Deltaproteobacteria) and hydrocarbon-rich environments (methanotrophs). Plume microbial communities are distinct from those on the seafloor or in the subsurface but contain some signatures of these habitats, consistent with the notion that plumes are potential vectors for dispersal of microorganisms between seafloor vent sites. Finally, we put forward three pressing questions for the future of deep-sea hydrothermal plume research and consider interactions between vents and oceans on global scales. PMID:23720658
Structure, stratigraphy, and eruption dynamics of a young tuff ring: Hanauma Bay, O'ahu, Hawai'i
NASA Astrophysics Data System (ADS)
Rottas, K. M.; Houghton, B. F.
2012-09-01
The Hanauma Bay-Koko Head complex is one of several young volcanic landforms along the Koko fissure, in southeastern O'ahu. The Hanauma Bay region of the complex comprises two nested tuff rings, inner and outer Hanauma Bay, and multiple smaller vents. The internal structure of the inner tuff ring, well exposed due to subsequent breaching by the ocean and wave erosion, indicates that it formed during a minimum of five distinct phases of deposition that produced five mappable units. Significant inward collapses generated major unconformities that separate the units exposed in the inner wall. The planes of failure are cut by narrow steep-walled, locally overhung channels and gullies, suggesting that the collapse events were each followed by short time breaks during which the deposits were eroded by rainfall runoff. Within each pyroclastic unit, there are many local slump scars and unconformities, suggesting that minor instability of the inner wall was a near-constant feature. From bedding sags and surge bed forms, it is apparent that the vent shifted at least twice during tuff ring growth. Ballistic blocks in the youngest unit indicate that the eruption overlapped in time with a separate eruption to the north, most likely to be that of the Kahauloa tuff ring 880 m away.
NASA Astrophysics Data System (ADS)
Katata, Genki; Chino, Masamichi; Terada, Hiroaki; Kobayashi, Takuya; Ota, Masakazu; Nagai, Haruyasu; Kajino, Mizuo
2014-05-01
Temporal variations of release amounts of radionuclides during the Fukushima Dai-ichi Nuclear Power Plant (FNPP1) accident and their dispersion process are essential to evaluate the environmental impacts and resultant radiological doses to the public. Here, we estimated a detailed time trend of atmospheric releases during the accident by combining environmental monitoring data and coupling atmospheric and oceanic dispersion simulations by WSPEEDI-II (Worldwide version of System for Prediction of Environmental Emergency Dose Information) and SEA-GEARN developed by the authors. New schemes for wet, dry, and fog depositions of radioactive iodine gas (I2 and CH3I) and other particles (I-131, Te-132, Cs-137, and Cs-134) were incorporated into WSPEEDI-II. The deposition calculated by WSPEEDI-II was used as input data of ocean dispersion calculations by SEA-GEARN. The reverse estimation method based on the simulation by both models assuming unit release rate (1 Bq h-1) was adopted to estimate the source term at the FNPP1 using air dose rate, and air sea surface concentrations. The results suggested that the major release of radionuclides from the FNPP1 occurred in the following periods during March 2011: afternoon on the 12th when the venting and hydrogen explosion occurred at Unit 1, morning on the 13th after the venting event at Unit 3, midnight on the 14th when several openings of SRV (steam relief valve) were conducted at Unit 2, morning and night on the 15th, and morning on the 16th. The modified WSPEEDI-II using the newly estimated source term well reproduced local and regional patterns of air dose rate and surface deposition of I-131 and Cs-137 obtained by airborne observations. Our dispersion simulations also revealed that the highest radioactive contamination areas around FNPP1 were created from 15th to 16th March by complicated interactions among rainfall (wet deposition), plume movements, and phase properties (gas or particle) of I-131 and release rates associated with reactor pressure variations in Units 2 and 3.
The origin of life in alkaline hydrothermal vents
NASA Astrophysics Data System (ADS)
Sojo, V.; Herschy, B.; Whicher, A.; Camprubí, E.; Lane, N.
2016-12-01
The origin of life remains one of Science's greatest unresolved questions. The answer will no doubt involve almost all the basic disciplines, including Physics, Chemistry, Astronomy, Geology, and Biology. Chiefly, it is the link between the latter two that must be elucidated: how geochemistry gave rise to biochemistry. Serpentinizing systems such as alkaline hydrothermal vents offer the most robust combination of conditions to have hosted the origin of life on the early Earth, while bearing many parallels to modern living cells. Stark gradients of concentration, pH, oxidation/reduction, and temperature provided the ability to synthesise and concentrate organic products, drive polymerisation reactions, and develop an autotrophic lifestyle independent of foreign sources of organics. In the oxygen-depleted waters of the Hadean, alkaline vents would have acted as electrochemical flow reactors, in which alkaline fluids saturated in H2 mixed with the relatively acidic CO2-rich waters of the ocean, through interconnected micropores made of thin inorganic walls containing catalytic Fe(Ni)S minerals. Perhaps not coincidentally, the unit cells of these Fe(Ni)S minerals closely resemble the active sites of crucial ancestral bioenergetic enzymes. Meanwhile, differences in pH across the thin barriers produced natural proton gradients similar to those used for carbon fixation in modern archaea and bacteria. At the earliest stages, the problem of the origin of life is the problem of the origin of carbon fixation. I will discuss work over the last decade that suggests several possible hypotheses for how simple one-carbon molecules could have given rise to more complex organics, particularly within a serpentinizing alkaline hydrothermal vent. I will discuss the perplexing differences in carbon and energy metabolism in methanogenic archaea and acetogenic bacteria, thought to be the earliest representatives of each domain, to propose a possible ancestral mechanism of CO2 reduction in alkaline hydrothermal vents. Based on this mechanism, I will show that an origin of life in alkaline hydrothermal vents can explain the deep divergence in cell membranes and active ion pumping between archaea and bacteria, from a vent-bound last universal common ancestor (LUCA). Life's most puzzling traits may give a pointer to its origin.
Wilson, P R
1996-07-01
The marginal adaptation of full coverage restorations is adversely affected by the introduction of luting agents of various minimum film thicknesses during the cementation process. The increase in the marginal opening may have long-term detrimental effects on the health of both pulpal and periodontal tissues. The purpose of this study was to determine the effects of varying seating forces (2.5, 12.5, 25 N), venting, and cement types on post-cementation marginal elevation in cast crowns. A standardized cement space of 40 microns was provided between a machined gold crown and a stainless steel die. An occlusal vent was placed that could be opened or closed. The post-cementation crown elevation was measured, following the use of two commercially available capsulated dental cements (Phosphacap, and Ketac-cem Applicap). The results indicate that only the combination of Ketac-Cem Applicap and crown venting produced post-cementation crown elevation of less than 20 microns when 12.5 N seating force was used. Higher forces (25 N) and venting were required for comparable seating when using Phosphacap (19 microns). The amount of force required to allow maximum seating of cast crowns appears to be cement specific, and is reduced by effective venting procedures.
NASA Technical Reports Server (NTRS)
Flachbart, Robin; Hedayat, Ali; Holt, Kimberly A.; Cruit, Wendy (Technical Monitor)
2001-01-01
The Advanced Shuttle Upper Stage (ASUS) concept addresses safety concerns associated .with cryogenic stages by launching empty, and filling on ascent. The ASUS employs a rapid chill and fill concept. A spray bar is used to completely chill the tank before fill, allowing the vent valve to be closed during the fill process. The first tests of this concept, using a flight size (not flight weight) tank. were conducted at Marshall Space Flight Center (MSFC) during the summer of 2000. The objectives of the testing were to: 1) demonstrate that a flight size tank could be filled in roughly 5 minutes to accommodate the shuttle ascent window, and 2) demonstrate a no-vent fill of the tank. A total of 12 tests were conducted. Models of the test facility fill and vent systems, as well as the tank, were constructed. The objective of achieving tank fill in 5 minutes was met during the test series. However, liquid began to accumulate in the tank before it was chilled. Since the tank was not chilled until the end of each test, vent valve closure during fill was not possible. Even though the chill and fill process did not occur as expected, reasonable model correlation with the test data was achieved.
Reconstructing an Explosive Basaltic Eruption in the Pinacate Volcanic Field, NW Sonora, Mexico
NASA Astrophysics Data System (ADS)
Zawacki, E. E.; Clarke, A. B.; Arrowsmith, R.; Lynch, D. J.
2017-12-01
Tephra deposits from explosive volcanic eruptions provide a means to reconstruct eruption characteristics, such as column height and erupted volume. Parameters like these are essential in assessing the explosivity of past eruptions and associated volcanic hazards. We applied such methods to a basaltic tephra deposit from one of the youngest eruptions in the Pinacate volcanic field (NW Sonora, Mexico). This roughly circular tephra blanket extends 13 km E-W and 13 km N-S, and covers an area of at least 135 km2. The source vent of this eruption is hypothesized to be the Tecolote volcano (lat 31.877, long -113.362), which is dated to 27 ± 6 ka (40Ar/39Ar). Fifty-three pits were dug across the extent of the tephra deposit to measure its thickness, record stratigraphy, characterize grain size distribution, and determine maximum clast size. Isopleth and isopach maps were created from these data to determine the column height (>9 km), estimate mass eruption rate (>2.1x106 kg/s), and calculate the erupted volume (>4.2x10-2 km3). Stratigraphic descriptions support two distinct episodes of tephra production. Unit A is dispersed in an approximately circular pattern ( 6.5 km radius) with its center shifted to the east of the vent. The distribution of Unit B is oblate ( 9.5 km major axis, 4.5 km minor axis) and trends to the southeast of the vent. Lava samples were collected from each of the seven Tecolote flows for XRF and ICP-MS geochemical analyses. These samples were compared to geochemical signatures from a Tecolote bomb, tephra from Units A and B, and cinder from the La Laja cone, which is the youngest dated cone in the field at 12 ± 4 ka (40Ar/39Ar). The La Laja sample is geochemically distinct from all Tecolote samples, confirming that it did not contribute to the two tephra units. Tephra from Unit A and Unit B have distinct signatures and fit within the geochemical evolution of the Tecolote lavas, supporting two explosive episodes from the Tecolote volcano, which has two cones. To provide a stronger age constraint on the eruption, samples for optically stimulated luminescence (OSL) dating were collected from the sandy silt unit below the tephra in two pits. Data for these dates are being analyzed.
NASA Astrophysics Data System (ADS)
McDermott, J. M.; Seewald, J.; German, C. R.; Sylva, S. P.
2013-12-01
The generation of organic compounds in vent fluids has been of interest since the discovery of seafloor hydrothermal systems, due to implications for the sustenance of present-day microbial populations and their potential role in the origin of life on early Earth. Possible sources of organic compounds in hydrothermal systems include microbial production, thermogenic degradation of organic material, and abiotic synthesis. Abiotic organic synthesis reactions may occur during active circulation of seawater-derived fluids through the oceanic crust or within olivine-hosted fluid inclusions containing carbon-rich magmatic volatiles. H2-rich end-member fluids at the Von Damm vent field on the Mid-Cayman Rise, where fluid temperatures reach 226°C, provide an exciting opportunity to examine the extent of abiotic carbon transformations in a highly reducing system. Our results indicate multiple sources of carbon compounds in vent fluids at Von Damm. An ultramafic-influenced hydrothermal system located on the Mount Dent oceanic core complex at 2350 m depth, Von Damm vent fluids contain H2, CH4, and C2+ hydrocarbons in high abundance relative to basalt-hosted vent fields, and in similar abundance to other ultramafic-hosted systems, such as Rainbow and Lost City. The CO2 content and isotopic composition in end-member fluids are virtually identical to bottom seawater, suggesting that seawater DIC is unchanged during hydrothermal circulation of seawater-derived fluids. Accordingly, end-member CH4 that is present in slightly greater abundance than CO2 cannot be generated from reduction of aqueous CO2 during hydrothermal circulation. We postulate that CH4 and C2+ hydrocarbons that are abundantly present in Von Damm vent fluids reflect leaching of fluids from carbon- and H2-rich fluid inclusions hosted in plutonic rocks. Geochemical modeling of carbon speciation in the Von Damm fluids suggests that the relative abundances of CH4, C2+ hydrocarbons, and CO2 are consistent with thermodynamic equilibrium at higher temperatures and more reducing conditions than those observed in the Von Damm vent fluids. These findings are consistent with a scenario in which n-alkanes form abiotically within a high-H2, carbon-rich olivine-hosted fluid inclusion, and are subsequently liberated and transported to the seafloor during hydrothermal alteration of the lower crustal rocks exposed at the Mount Dent oceanic core complex. Mixed fluids at Von Damm show depletions in CO2 and H2, relative to conservative mixing. Multiple S isotope measurements indicate that the H2 sink cannot be attributed to sulfate reduction. Thermodynamic constraints indicate that high-H2 conditions support the active formation of formate via reduction of dissolved CO2 during hydrothermal circulation - a process that has also been described at the Lost City vent field - and could account for the concurrent depletions in CO2 and H2. The transformation of inorganic carbon to organic compounds via two distinct pathways in modern seafloor hydrothermal vents validates theoretical and experimental conceptual models regarding processes occurring in the crust and during hydrothermal circulation, and is relevant to supporting life in vent ecosystems.
Battery Vent Mechanism And Method
Ching, Larry K. W.
2000-02-15
Disclosed herein is a venting mechanism for a battery. The venting mechanism includes a battery vent structure which is located on the battery cover and may be integrally formed therewith. The venting mechanism includes an opening extending through the battery cover such that the opening communicates with a plurality of battery cells located within the battery case. The venting mechanism also includes a vent manifold which attaches to the battery vent structure. The vent manifold includes a first opening which communicates with the battery vent structure opening and second and third openings which allow the vent manifold to be connected to two separate conduits. In this manner, a plurality of batteries may be interconnected for venting purposes, thus eliminating the need to provide separate vent lines for each battery. The vent manifold may be attached to the battery vent structure by a spin-welding technique. To facilitate this technique, the vent manifold may be provided with a flange portion which fits into a corresponding groove portion on the battery vent structure. The vent manifold includes an internal chamber which is large enough to completely house a conventional battery flame arrester and overpressure safety valve. In this manner, the vent manifold, when installed, lessens the likelihood of tampering with the flame arrester and safety valve.
Battery venting system and method
Casale, T.J.; Ching, L.K.W.; Baer, J.T.; Swan, D.H.
1999-01-05
Disclosed herein is a venting mechanism for a battery. The venting mechanism includes a battery vent structure which is located on the battery cover and may be integrally formed therewith. The venting mechanism includes an opening extending through the battery cover such that the opening communicates with a plurality of battery cells located within the battery case. The venting mechanism also includes a vent manifold which attaches to the battery vent structure. The vent manifold includes a first opening which communicates with the battery vent structure opening and second and third openings which allow the vent manifold to be connected to two separate conduits. In this manner, a plurality of batteries may be interconnected for venting purposes, thus eliminating the need to provide separate vent lines for each battery. The vent manifold may be attached to the battery vent structure by a spin-welding technique. To facilitate this technique, the vent manifold may be provided with a flange portion which fits into a corresponding groove portion on the battery vent structure. The vent manifold includes an internal chamber which is large enough to completely house a conventional battery flame arrester and overpressure safety valve. In this manner, the vent manifold, when installed, lessens the likelihood of tampering with the flame arrester and safety valve. 8 figs.
Battery venting system and method
Casale, Thomas J.; Ching, Larry K. W.; Baer, Jose T.; Swan, David H.
1999-01-05
Disclosed herein is a venting mechanism for a battery. The venting mechanism includes a battery vent structure which is located on the battery cover and may be integrally formed therewith. The venting mechanism includes an opening extending through the battery cover such that the opening communicates with a plurality of battery cells located within the battery case. The venting mechanism also includes a vent manifold which attaches to the battery vent structure. The vent manifold includes a first opening which communicates with the battery vent structure opening and second and third openings which allow the vent manifold to be connected to two separate conduits. In this manner, a plurality of batteries may be interconnected for venting purposes, thus eliminating the need to provide separate vent lines for each battery. The vent manifold may be attached to the battery vent structure by a spin-welding technique. To facilitate this technique, the vent manifold may be provided with a flange portion which fits into a corresponding groove portion on the battery vent structure. The vent manifold includes an internal chamber which is large enough to completely house a conventional battery flame arrester and overpressure safety valve. In this manner, the vent manifold, when installed, lessens the likelihood of tampering with the flame arrester and safety valve.
NASA Astrophysics Data System (ADS)
Crone, T. J.; Kinsey, J. C.; Mittelstaedt, E. L.
2017-12-01
Hydrothermal venting at mid-ocean ridges influences ocean chemistry, the thermal and chemical structure of the oceanic crust, and the evolution of unique and diverse autolithotrophically-supported ecosystems. Axially-hosted hydrothermal systems are responsible for 20-25% of the total heat flux out of Earth's interior, and likely play a large role in local as well as global biogeochemical cycles. Despite the importance of these systems, only a few studies have attempted to constrain the volume and heat flux of an entire hydrothermal vent field. In July of 2014 we used the Sentry autonomous underwater vehicle (AUV) to survey the water column over the ASHES hydrothermal vent field which is located within the caldera of Axial Seamount, an active submarine volcano located on the Juan de Fuca Ridge. To estimate the total heat and mass flux from this vent field, we equipped Sentry with a Nortek acoustic Doppler velocimeter (ADV), an inertial measurement unit (IMU), two acoustic Doppler current profilers (ADCPs), and two SBE3 temperature probes, allowing us to obtain precise measurements of fluid temperature and water velocity. The survey was designed using a control volume approach in which Sentry was pre-programmed to survey a 150-m-square centered over the vent field flying a grid pattern with 5-m track line spacing followed by a survey of the perimeter. This pattern was repeated multiple times during several 10-h dives at different altitudes, including 10, 20, 40, and 60 m above the seafloor, and during one 40-h survey at an altitude of 10 m. During the 40-h survey, the pattern was repeated nine times allowing us to obtain observations over several tidal cycles. Water velocity data obtained with Sentry were corrected for platform motion and then combined with the temperature measurements to estimate heat flux. The analysis of these data will likely provide the most accurate and highest resolution heat and mass flux estimates at a seafloor hydrothermal field to date.
NASA Technical Reports Server (NTRS)
Saiidi, M. J.; Duffy, R. E.; Mclaughlin, T. D.
1986-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis/Critical Items List (FMEA/CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The independent analysis results corresponding to the Orbiter Atmospheric Revitalization and Pressure Control Subsystem (ARPCS) are documented. The ARPCS hardware was categorized into the following subdivisions: (1) Atmospheric Make-up and Control (including the Auxiliary Oxygen Assembly, Oxygen Assembly, and Nitrogen Assembly); and (2) Atmospheric Vent and Control (including the Positive Relief Vent Assembly, Negative Relief Vent Assembly, and Cabin Vent Assembly). The IOA analysis process utilized available ARPCS hardware drawings and schematics for defining hardware assemblies, components, and hardware items. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode.
Boatta, F; D'Alessandro, W; Gagliano, A L; Liotta, M; Milazzo, M; Rodolfo-Metalpa, R; Hall-Spencer, J M; Parello, F
2013-08-30
Shallow submarine gas vents in Levante Bay, Vulcano Island (Italy), emit around 3.6t CO2 per day providing a natural laboratory for the study of biogeochemical processes related to seabed CO2 leaks and ocean acidification. The main physico-chemical parameters (T, pH and Eh) were measured at more than 70 stations with 40 seawater samples were collected for chemical analyses. The main gas vent area had high concentrations of dissolved hydrothermal gases, low pH and negative redox values all of which returned to normal seawater values at distances of about 400m from the main vents. Much of the bay around the vents is corrosive to calcium carbonate; the north shore has a gradient in seawater carbonate chemistry that is well suited to studies of the effects of long-term increases in CO2 levels. This shoreline lacks toxic compounds (such as H2S) and has a gradient in carbonate saturation states. Copyright © 2013 Elsevier Ltd. All rights reserved.
Sonic Anemometry to Measure Natural Ventilation in Greenhouses
López, Alejandro; Valera, Diego Luis; Molina-Aiz, Francisco
2011-01-01
The present work has developed a methodology for studying natural ventilation in Mediterranean greenhouses by means of sonic anemometry. In addition, specific calculation programmes have been designed to enable processing and analysis of the data recorded during the experiments. Sonic anemometry allows us to study the direction of the airflow at all the greenhouse vents. Knowing through which vents the air enters and leaves the greenhouse enables us to establish the airflow pattern of the greenhouse under natural ventilation conditions. In the greenhouse analysed in this work for Poniente wind (from the southwest), a roof vent designed to open towards the North (leeward) could allow a positive interaction between the wind and stack effects, improving the ventilation capacity of the greenhouse. The cooling effect produced by the mass of turbulent air oscillating between inside and outside the greenhouse at the side vents was limited to 2% (for high wind speed, uo ≥ 4 m s−1) reaching 36.3% when wind speed was lower (uo = 2 m s−1). PMID:22163728
Thermodynamic modeling of the no-vent fill methodology for transferring cryogens in low gravity
NASA Technical Reports Server (NTRS)
Chato, David J.
1988-01-01
The filling of tanks with cryogens in the low-gravity environment of space poses many technical challenges. Chief among these is the inability to vent only vapor from the tank as the filling proceeds. As a potential solution to this problem, the NASA Lewis Research Center is researching a technique known as No-Vent Fill. This technology potentially has broad application. The focus is the fueling of space based Orbital Transfer Vehicles. The fundamental thermodynamics of the No-Vent Fill is described. The model is then used to conduct a parametric investigation of the key parameters: initial tank wall temperature, liquid-vapor interface heat transfer rate, liquid inflow rate, and inflowing liquid temperatures. Liquid inflowing temperature and the liquid-vapor interface heat transfer rate seem to be the most significant since they influence the entire fill process. The initial tank wall temperature must be sufficiently low to prevent a rapid pressure rise during the initial liquid flashing state, but then becomes less significant.
Sonic anemometry to measure natural ventilation in greenhouses.
López, Alejandro; Valera, Diego Luis; Molina-Aiz, Francisco
2011-01-01
The present work has developed a methodology for studying natural ventilation in Mediterranean greenhouses by means of sonic anemometry. In addition, specific calculation programmes have been designed to enable processing and analysis of the data recorded during the experiments. Sonic anemometry allows us to study the direction of the airflow at all the greenhouse vents. Knowing through which vents the air enters and leaves the greenhouse enables us to establish the airflow pattern of the greenhouse under natural ventilation conditions. In the greenhouse analysed in this work for Poniente wind (from the southwest), a roof vent designed to open towards the North (leeward) could allow a positive interaction between the wind and stack effects, improving the ventilation capacity of the greenhouse. The cooling effect produced by the mass of turbulent air oscillating between inside and outside the greenhouse at the side vents was limited to 2% (for high wind speed, u(o) ≥ 4 m s(-1)) reaching 36.3% when wind speed was lower (u(o) = 2 m s(-1)).
14 CFR 29.975 - Fuel tank vents and carburetor vapor vents.
Code of Federal Regulations, 2014 CFR
2014-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.975 Fuel tank vents and carburetor vapor vents. (a) Fuel tank vents. Each fuel tank must be vented from the... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fuel tank vents and carburetor vapor vents...
14 CFR 29.975 - Fuel tank vents and carburetor vapor vents.
Code of Federal Regulations, 2010 CFR
2010-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.975 Fuel tank vents and carburetor vapor vents. (a) Fuel tank vents. Each fuel tank must be vented from the... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel tank vents and carburetor vapor vents...
14 CFR 25.975 - Fuel tank vents and carburetor vapor vents.
Code of Federal Regulations, 2014 CFR
2014-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.975 Fuel tank vents and carburetor vapor vents. (a) Fuel tank vents. Each fuel tank must be vented from the... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fuel tank vents and carburetor vapor vents...
14 CFR 29.975 - Fuel tank vents and carburetor vapor vents.
Code of Federal Regulations, 2013 CFR
2013-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.975 Fuel tank vents and carburetor vapor vents. (a) Fuel tank vents. Each fuel tank must be vented from the... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fuel tank vents and carburetor vapor vents...
14 CFR 29.975 - Fuel tank vents and carburetor vapor vents.
Code of Federal Regulations, 2011 CFR
2011-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.975 Fuel tank vents and carburetor vapor vents. (a) Fuel tank vents. Each fuel tank must be vented from the... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fuel tank vents and carburetor vapor vents...
14 CFR 29.975 - Fuel tank vents and carburetor vapor vents.
Code of Federal Regulations, 2012 CFR
2012-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.975 Fuel tank vents and carburetor vapor vents. (a) Fuel tank vents. Each fuel tank must be vented from the... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fuel tank vents and carburetor vapor vents...
14 CFR 25.975 - Fuel tank vents and carburetor vapor vents.
Code of Federal Regulations, 2010 CFR
2010-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.975 Fuel tank vents and carburetor vapor vents. (a) Fuel tank vents. Each fuel tank must be vented from the... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel tank vents and carburetor vapor vents...
14 CFR 25.975 - Fuel tank vents and carburetor vapor vents.
Code of Federal Regulations, 2011 CFR
2011-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.975 Fuel tank vents and carburetor vapor vents. (a) Fuel tank vents. Each fuel tank must be vented from the... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fuel tank vents and carburetor vapor vents...
14 CFR 25.975 - Fuel tank vents and carburetor vapor vents.
Code of Federal Regulations, 2012 CFR
2012-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.975 Fuel tank vents and carburetor vapor vents. (a) Fuel tank vents. Each fuel tank must be vented from the... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fuel tank vents and carburetor vapor vents...
14 CFR 25.975 - Fuel tank vents and carburetor vapor vents.
Code of Federal Regulations, 2013 CFR
2013-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.975 Fuel tank vents and carburetor vapor vents. (a) Fuel tank vents. Each fuel tank must be vented from the... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fuel tank vents and carburetor vapor vents...
Amino Acid Stability in the Early Oceans
NASA Technical Reports Server (NTRS)
Parker, E. T.; Brinton, K. L.; Burton, A. S.; Glavin, D. P.; Dworkin, J. P.; Bada, J. L.
2015-01-01
It is likely that a variety of amino acids existed in the early oceans of the Earth at the time of the origin and early evolution of life. "Primordial soup", hydrothermal vent, and meteorite based processes could have contributed to such an inventory. Several "protein" amino acids were likely present, however, based on prebiotic synthesis experiments and carbonaceous meteorite studies, non-protein amino acids, which are rare on Earth today, were likely the most abundant. An important uncertainty is the length of time these amino acids could have persisted before their destruction by abiotic and biotic processes. Prior to life, amino acid concentrations in the oceans were likely regulated by circulation through hydro-thermal vents. Today, the entire ocean circulates through vent systems every 10(exp 7) years. On the early Earth, this value was likely smaller due to higher heat flow and thus marine amino acid life-time would have been shorter. After life, amino acids in the oceans could have been assimilated by primitive organisms.
Chen, Jia-Qing; Zhang, Nan; Wang, Jin-Hui; Zhu, Ling; Shang, Chao
2011-12-01
With the gradual improvement of environmental regulations, more and more attentions are attracted to the vapor emissions during the process of vehicle refueling. Research onto the vehicle refueling process by means of numerical simulation has been executed abroad since 1990s, while as it has never been involved so far domestically. Through reasonable simplification about the physical system of "Nozzle + filler pipe + gasoline storage tank + vent pipe" for vehicle refueling, and by means of volume of fluid (VOF) model for gas-liquid two-phase flow and Re-Normalization Group kappa-epsilon turbulence flow model provided in commercial computational fluid dynamics (CFD) software Fluent, this paper determined the proper mesh discretization scheme and applied the proper boundary conditions based on the Gambit software, then established the reasonable numerical simulation model for the gas-liquid two-phase flow during the refueling process. Through discussing the influence of refueling velocity on the static pressure of vent space in gasoline tank, the back-flowing phenomenon has been revealed in this paper. It has been demonstrated that, the more the flow rate and the refueling velocity of refueling nozzle is, the higher the gross static pressure in the vent space of gasoline tank. In the meanwhile, the variation of static pressure in the vent space of gasoline tank can be categorized into three obvious stages. When the refueling flow rate becomes higher, the back-flowing phenomenon of liquid gasoline can sometimes be induced in the head section of filler pipe, thus making the gasoline nozzle pre-shut-off. Totally speaking, the theoretical work accomplished in this paper laid some solid foundation for self-researching and self-developing the technology and apparatus for the vehicle refueling and refueling emissions control domestically.
NASA Astrophysics Data System (ADS)
Xu, G.; Bemis, K. G.
2014-12-01
Seafloor hydrothermal systems feature intricate interconnections among oceanic, geological, hydrothermal, and biological processes. The advent of the NEPTUNE observatory operated by Ocean Networks Canada at the Endeavour Segment, Juan de Fuca Ridge enables scientists to study these interconnections through multidisciplinary, continuous, real-time observations. The multidisciplinary observatory instruments deployed at the Grotto Mound, a major study site of the NEPTUNE observatory, makes it a perfect place to study the response of a seafloor hydrothermal system to geological and oceanic processes. In this study, we use the multidisciplinary datasets recorded by the NEPTUNE Observatory instruments as observational tools to demonstrate two different aspects of the response of hydrothermal activity at the Grotto Mound to geological and oceanic processes. First, we investigate a recent increase in venting temperature and heat flux at Grotto observed by the Benthic and Resistivity Sensors (BARS) and the Cabled Observatory Vent Imaging Sonar (COVIS) respectively. This event started in Mar 2014 and is still evolving by the time of writing this abstract. An initial interpretation in light of the seismic data recorded by a neighboring ocean bottom seismometer on the NEPTUNE observatory suggests the temperature and heat flux increase is probably triggered by local seismic activities. Comparison of the observations with the results of a 1-D mathematical model simulation of hydrothermal sub-seafloor circulation elucidates the potential mechanisms underlying hydrothermal response to local earthquakes. Second, we observe significant tidal oscillations in the venting temperature time series recorded by BARS and the acoustic imaging of hydrothermal plumes by COVIS, which is evidence for hydrothermal response to ocean tides and currents. We interpret the tidal oscillations of venting temperature as a result of tidal loading on a poroelastic medium. We then invoke poroelastic theories to estimate the crustal permeability, a fundamental property of subsurface hydrothermal circulation, from the phase shift of the tidal oscillations of venting temperature relative to ambient ocean tides. These results together shed light on the influences of seismic and oceanic processes on a seafloor hydrothermal system.
NASA Astrophysics Data System (ADS)
Applegarth, Jane; James, Mike; Pinkerton, Harry
2010-05-01
The early stages of effusive volcanic eruptions, during which lava flows are lengthening, are often closely monitored for hazard management. Processes involved in lengthening are therefore relatively well understood, and lava flow development during this phase can be modelled with some success[1,2]. However, activity may continue after the lavas have reached their maximum length, leading to flow inflation, breakouts and possibly further lengthening of the flow field[3,4]. These processes can be difficult to observe during activity, and may result in highly complex flow morphologies that are not easily interpreted post-eruption. The late-stage development of compound flow fields is therefore important, but is currently an understudied area. The scale of this activity may vary greatly, and probably depends in part on the eruption duration. For example, the largest flow field emplaced during the 2001 eruption of Mt. Etna, Sicily, reached its maximum length of 6 km in 8 days, then was active for a further 2 weeks only. This ‘late-stage' activity involved the initiation of two new channels, a few tens of metres wide, which reached lengths of up to ~2 km. In contrast, the 2008-9 Etna eruption emplaced 6 km long flows within ~6 weeks, then activity continued for a further year. During the last few months of activity, small transient flows were extruded from ephemeral vents, several of which could be active at any given time. Observations of the late-stage activity this flow field as a whole allowed the influence of parameters such as effusion rate and topography on the overall morphology to be studied[5]. Furthermore, the scale of the individual flow units (a few metres wide, a few hundreds of metres long) meant that additional close-range measurements of their short-term development could be carried out, and the results are discussed here. We observed the behaviour of three such flow units, which were fed by a single ephemeral vent, over a 26-hour period within the last month of the 2008-9 Etna eruption. These were monitored using a time-lapse camera, only ~50 m from the vent, that collected images every 3 minutes. From the suite of images collected we observed flow inflation, changing surface textures, overflows, the formation of surface flows and breakouts, and the switching of activity between channels. These data provide unique insights into the processes that lead to the cessation of activity of small flows, and the initiation of new flow units. This approach, whereby processes are studied on small spatial and short temporal scales, may inform our interpretation of complex morphology in larger flow fields, such as that emplaced during the 2001 Etna eruption. Although the flow units in this case were an order of magnitude larger, the sequence of events leading to the initiation of new channels may be very similar. [1] Wright R, Garbeil H, Harris AJL (2008) Using infrared satellite data to drive a thermo-rheological/stochastic lava flow emplacement model: A method for near-real-time volcanic hazard assessment. Geophys Res Lett 35: L19307 [2] Vicari A, Herault A, Del Negro C, Coltelli M, Marsella M, Proietti C (2007) Modelling of the 2001 lava flow at Etna volcano by a Cellular Automata approach. Environ Model & Softw 22(10):1465-1471 [3] Luhr JF, Simkin T (1993) Parícutin, the volcano born in a Mexican cornfield. Geoscience Press, Arizona [4] Kilburn CRJ, Guest, JE (1993) `A`ā lavas of Mount Etna, Sicily. In: Kilburn, CRJ Luongo G (eds) Active lavas: monitoring and modelling. UCL Press, London, 73-106 [5] Pinkerton H, James MR, Applegarth LJ (2010) The importance of high resolution time-lapse imagery in unravelling complex processes during effusive volcanic eruptions. EGU Abstract 5193
Lamare, Miles D; Liddy, Michelle; Uthicke, Sven
2016-11-30
Laboratory experiments suggest that calcifying developmental stages of marine invertebrates may be the most ocean acidification (OA)-sensitive life-history stage and represent a life-history bottleneck. To better extrapolate laboratory findings to future OA conditions, developmental responses in sea urchin embryos/larvae were compared under ecologically relevant in situ exposures on vent-elevated pCO 2 and ambient pCO 2 coral reefs in Papua New Guinea. Echinometra embryos/larvae were reared in meshed chambers moored in arrays on either venting reefs or adjacent non-vent reefs. After 24 and 48 h, larval development and morphology were quantified. Compared with controls (mean pH (T) = 7.89-7.92), larvae developing in elevated pCO 2 vent conditions (pH (T) = 7.50-7.72) displayed a significant reduction in size and increased abnormality, with a significant correlation of seawater pH with both larval size and larval asymmetry across all experiments. Reciprocal transplants (embryos from vent adults transplanted to control conditions, and vice versa) were also undertaken to identify if adult acclimatization can translate resilience to offspring (i.e. transgenerational processes). Embryos originating from vent adults were, however, no more tolerant to reduced pH. Sea temperature and chlorophyll-a concentrations (i.e. larval nutrition) did not contribute to difference in larval size, but abnormality was correlated with chlorophyll levels. This study is the first to examine the response of marine larvae to OA scenarios in the natural environment where, importantly, we found that stunted and abnormal development observed in situ are consistent with laboratory observations reported in sea urchins, in both the direction and magnitude of the response. © 2016 The Author(s).
Liddy, Michelle; Uthicke, Sven
2016-01-01
Laboratory experiments suggest that calcifying developmental stages of marine invertebrates may be the most ocean acidification (OA)-sensitive life-history stage and represent a life-history bottleneck. To better extrapolate laboratory findings to future OA conditions, developmental responses in sea urchin embryos/larvae were compared under ecologically relevant in situ exposures on vent-elevated pCO2 and ambient pCO2 coral reefs in Papua New Guinea. Echinometra embryos/larvae were reared in meshed chambers moored in arrays on either venting reefs or adjacent non-vent reefs. After 24 and 48 h, larval development and morphology were quantified. Compared with controls (mean pH(T) = 7.89–7.92), larvae developing in elevated pCO2 vent conditions (pH(T) = 7.50–7.72) displayed a significant reduction in size and increased abnormality, with a significant correlation of seawater pH with both larval size and larval asymmetry across all experiments. Reciprocal transplants (embryos from vent adults transplanted to control conditions, and vice versa) were also undertaken to identify if adult acclimatization can translate resilience to offspring (i.e. transgenerational processes). Embryos originating from vent adults were, however, no more tolerant to reduced pH. Sea temperature and chlorophyll-a concentrations (i.e. larval nutrition) did not contribute to difference in larval size, but abnormality was correlated with chlorophyll levels. This study is the first to examine the response of marine larvae to OA scenarios in the natural environment where, importantly, we found that stunted and abnormal development observed in situ are consistent with laboratory observations reported in sea urchins, in both the direction and magnitude of the response. PMID:27903867
NASA Astrophysics Data System (ADS)
Olins, H. C.; Rogers, D.; Scholin, C. A.; Preston, C. J.; Vidoudez, C.; Ussler, W.; Pargett, D.; Jensen, S.; Roman, B.; Birch, J. M.; Girguis, P. R.
2014-12-01
Hydrothermal vents are hotspots of microbial primary productivity often described as "windows into the subsurface biosphere." High temperature vents have received the majority of research attention, but cooler diffuse flows are as, if not more, important a source of heat and chemicals to the overlying ocean. We studied patterns of in situ gene expression and co-registered geochemistry in order to 1) describe the diversity and physiological poise of active microbial communities that span thermal and geochemical gradients from active diffuse flow to background vent field seawater, and 2) determine to what extent seawater or subsurface microbes were active throughout this environment. Analyses of multiple metatranscriptomes from 5 geochemically distinct sites (some from samples preserved in situ) show that proximate diffuse flows showed strikingly different transcription profiles. Specifically, caldera background and some diffuse flows were similar, both dominated by seawater-derived Gammaproteobacteria despite having distinct geochemistries. Intra-field community shows evidence of increased primary productivity throughout the entire vent field and not just at individual diffuse flows. In contrast, a more spatially limited, Epsilonproteobacteria-dominated transcription profile from the most hydrothermally-influenced diffuse flow appeared to be driven by the activity of vent-endemic microbes, likely reflecting subsurface microbial activity. We suggest that the microbial activity within many diffuse flow vents is primarily attributable to seawater derived Gammaproteobacterial sulfur oxidizers, while in certain other flows vent-endemic Epsilonproteobactiera are most active. These data reveal a diversity in microbial activity at diffuse flows that has not previously been recognized, and reshapes our thinking about the relative influence that different microbial communities may have on local processes (such as primary production) and potentially global biogeochemical cycles.
Management of Open Pneumothorax in Tactical Combat Casualty Care: TCCC Guidelines Change 13-02.
Butler, Frank K; Dubose, Joseph J; Otten, Edward J; Bennett, Donald R; Gerhardt, Robert T; Kheirabadi, Bijan S; Gross, Kriby R; Cap, Andrew P; Littlejohn, Lanny F; Edgar, Erin P; Shackelford, Stacy A; Blackbourne, Lorne H; Kotwal, Russ S; Holcomb, John B; Bailey, Jeffrey A
2013-01-01
During the recent United States Central Command (USCENTCOM) and Joint Trauma System (JTS) assessment of prehospital trauma care in Afghanistan, the deployed director of the Joint Theater Trauma System (JTTS), CAPT Donald R. Bennett, questioned why TCCC recommends treating a nonlethal injury (open pneumothorax) with an intervention (a nonvented chest seal) that could produce a lethal condition (tension pneumothorax). New research from the U.S. Army Institute of Surgical Research (USAISR) has found that, in a model of open pneumothorax treated with a chest seal in which increments of air were added to the pleural space to simulate an air leak from an injured lung, use of a vented chest seal prevented the subsequent development of a tension pneumothorax, whereas use of a nonvented chest seal did not. The updated TCCC Guideline for the battlefield management of open pneumothorax is: ?All open and/ or sucking chest wounds should be treated by immediately applying a vented chest seal to cover the defect. If a vente chest seal is not available, use a non-vented chest seal. Monitor the casualty for the potential development of a subsequent tension pneumothorax. If the casualty develops increasing hypoxia, respiratory distress, or hypotension and a tension pneumothorax is suspected, treat by burping or removing the dressing or by needle decompression.? This recommendation was approved by the required two-thirds majority of the Committee on TCCC in June 2013. 2013.
Wang, Minxiao; Liu, Yuan; Hui, Min
2017-01-01
For deep-sea hydrothermal vent crabs, recent investigations have revealed some epibiotic bacteria, but no study has described the bacterial community associated with the gill and intestine. In this study, the microbiota attached to the gill and intestine of the hydrothermal vent crab Austinograea sp. and two shallow-water crab species (Eriocheir sinensis and Portunus trituberculatus) were compared by high-throughput sequencing of 16S rDNA genes. The highest and lowest diversity in bacterial communities were observed in the gill and intestine of Austinograea sp., respectively. Non-metric multidimensional scaling (NMDS) analysis indicated that Austinograea sp. harbored a distinct microbial community. Operational taxonomic units (OTUs) for phylum Fusobacteria, class Epsilonproteobacteria, and genera Leucothrix, Polaribacter, Fusibacter, etc. were dominant in Austinograea sp. Of these, Leucothrix, Sulfurospirillum, and Arcobacter may be involved in oxidizing reduced sulfur compounds and sulfur metabolism; Marinomonas, Polaribacter adapted to the low temperature, and Fusibacter and Psychrilyobacter may survive well under hypoxic conditions. Bacteria commonly present in seawater were dominant in the gill, whereas anaerobic bacteria showed strikingly high abundance in the intestine. Interestingly, Firmicutes and Epsilonproteobacteria may complement each other in Austinograea sp., forming an internal environment. The diversified microbial community of Austinograea sp. reveals adaptation to the hydrothermal vent environment. PMID:29121118
Inside the volcano: The how and why of Thrihnukagigur volcano, Iceland
NASA Astrophysics Data System (ADS)
LaFemina, Peter; Hudak, Michael; Feineman, Maureen; Geirsson, Halldor; Normandeau, Jim; Furman, Tanya
2015-04-01
The Thrihnukagigur volcano, located in the Brennisteinsfjöll fissure swarm on the Reykjanes Peninsula, Iceland, offers a unique exposure of the upper magmatic plumbing system of a monogenetic volcano. The volcano formed during a dike-fed strombolian eruption ~3500 BP with flow-back leaving an evacuated conduit, elongated parallel to the regional maximum horizontal stress. At least two vents were formed above the dike, as well as several small hornitos south-southwest of the main vent. In addition to the evacuated conduit, a cave exists 120 m below the vent. The cave exposes stacked lava flows and a buried cinder cone. The unconsolidated tephra of the cone is cross-cut by a NNE-trending dike, which runs across the ceiling of this cave to the vent that produced lava and tephra during the ~3500 BP fissure eruption. We present geochemical, petrologic and geologic observations, including a high-resolution three-dimensional scan of the system that indicate the dike intersected, eroded and assimilated unconsolidated tephra from the buried cinder cone, thus excavating a region along the dike, allowing for future slumping and cave formation. Two petrographically distinct populations of plagioclase phenocrysts are present in the system: a population of smaller (maximum length 1 mm) acicular phenocrysts and a population of larger (maximum length 10 mm) tabular phenocrysts that is commonly broken and displays disequilibrium sieve textures. The acicular plagioclase crystals are present in the dike and lavas while the tabular crystals are in these units and the buried tephra. An intrusion that appears not to have interacted with the tephra has only acicular plagioclase. This suggests that a magma crystallizing a single acicular population of plagioclase intruded the cinder cone and rapidly assimilated the tephra, incorporating the tabular population of phenocrysts from the cone. Petrographic thin-sections of lavas sampled near the vent show undigested fragments of tephra from the cone. This conceptual model for basaltic cannibalism is supported by field observations of large-scale erosion upward into the tephra, which is coated by magma flow-back indicating that magma was involved in the physical erosion of the tephra. Whole rock major and trace element geochemical data are consistent with this model of mixing between the intruded magma and the tephra. While the unique exposure at Thrihnukagigur makes it an exceptional place to investigate basaltic cannibalism, we suggest that it is not limited to this volcanic system. Rather it is a process that likely occurs throughout Iceland and may contribute to the evolution of the crust in other predominately basaltic settings.
NASA Astrophysics Data System (ADS)
Tadini, A.; Bisson, M.; Neri, A.; Cioni, R.; Bevilacqua, A.; Aspinall, W. P.
2017-06-01
This study presents new and revised data sets about the spatial distribution of past volcanic vents, eruptive fissures, and regional/local structures of the Somma-Vesuvio volcanic system (Italy). The innovative features of the study are the identification and quantification of important sources of uncertainty affecting interpretations of the data sets. In this regard, the spatial uncertainty of each feature is modeled by an uncertainty area, i.e., a geometric element typically represented by a polygon drawn around points or lines. The new data sets have been assembled as an updatable geodatabase that integrates and complements existing databases for Somma-Vesuvio. The data are organized into 4 data sets and stored as 11 feature classes (points and lines for feature locations and polygons for the associated uncertainty areas), totaling more than 1700 elements. More specifically, volcanic vent and eruptive fissure elements are subdivided into feature classes according to their associated eruptive styles: (i) Plinian and sub-Plinian eruptions (i.e., large- or medium-scale explosive activity); (ii) violent Strombolian and continuous ash emission eruptions (i.e., small-scale explosive activity); and (iii) effusive eruptions (including eruptions from both parasitic vents and eruptive fissures). Regional and local structures (i.e., deep faults) are represented as linear feature classes. To support interpretation of the eruption data, additional data sets are provided for Somma-Vesuvio geological units and caldera morphological features. In the companion paper, the data presented here, and the associated uncertainties, are used to develop a first vent opening probability map for the Somma-Vesuvio caldera, with specific attention focused on large or medium explosive events.
Code of Federal Regulations, 2012 CFR
2012-07-01
... discrete venting episode that may be associated with a single unit operation. For example, a displacement of vapor resulting from the charging of a vessel with HAP will result in a discrete emission episode... of the charge. If the vessel is then heated, there will also be another discrete emission episode...
Code of Federal Regulations, 2014 CFR
2014-07-01
... discrete venting episode that may be associated with a single unit operation. For example, a displacement of vapor resulting from the charging of a vessel with HAP will result in a discrete emission episode... of the charge. If the vessel is then heated, there will also be another discrete emission episode...
Code of Federal Regulations, 2013 CFR
2013-07-01
... discrete venting episode that may be associated with a single unit operation. For example, a displacement of vapor resulting from the charging of a vessel with HAP will result in a discrete emission episode... of the charge. If the vessel is then heated, there will also be another discrete emission episode...
Code of Federal Regulations, 2011 CFR
2011-07-01
... discrete venting episode that may be associated with a single unit operation. For example, a displacement of vapor resulting from the charging of a vessel with HAP will result in a discrete emission episode... of the charge. If the vessel is then heated, there will also be another discrete emission episode...
Features of lava lake filling and draining and their implications for eruption dynamics
Stovall, W.K.; Houghton, Bruce F.; Harris, A.J.L.; Swanson, D.A.
2009-01-01
Lava lakes experience filling, circulation, and often drainage depending upon the style of activity and location of the vent. Features formed by these processes have proved difficult to document due to dangerous conditions during the eruption, inaccessibility, and destruction of features during lake drainage. Kilauea Iki lava lake, Kilauea, Hawai'i, preserves many such features, because lava ponded in a pre-existing crater adjacent to the vent and eventually filled to the level of, and interacted with, the vent and lava fountains. During repeated episodes, a cyclic pattern of lake filling to above vent level, followed by draining back to vent level, preserved features associated with both filling and draining. Field investigations permit us to describe the characteristic features associated with lava lakes on length scales ranging from centimeters to hundreds of meters in a fashion analogous to descriptions of lava flows. Multiple vertical rinds of lava coating the lake walls formed during filling as the lake deepened and lava solidified against vertical faces. Drainage of the lake resulted in uneven formation of roughly horizontal lava shelves on the lakeward edge of the vertical rinds; the shelves correlate with stable, staggered lake stands. Shelves either formed as broken relict slabs of lake crust that solidified in contact with the wall or by accumulation, accretion, and widening at the lake surface in a dynamic lateral flow regime. Thin, upper lava shelves reflect an initially dynamic environment, in which rapid lake lowering was replaced by slower and more staggered drainage with the formation of thicker, more laterally continuous shelves. At all lava lakes experiencing stages of filling and draining these processes may occur and result in the formation of similar sets of features. ?? Springer-Verlag 2009.
NASA Astrophysics Data System (ADS)
Capponi, Antonio; Lane, Stephen J.; James, Mike R.
2017-06-01
The interpretation of geophysical measurements at active volcanoes is vital for hazard assessment and for understanding fundamental processes such as magma degassing. For Strombolian activity, interpretations are currently underpinned by first-order fluid dynamic models which give relatively straightforward relationships between geophysical signals and gas and magma flow. However, recent petrological and high-speed video evidence has indicated the importance of rheological stratification within the conduit and, here, we show that under these conditions, the straightforward relationships break down. Using laboratory analogue experiments to represent a rheologically-stratified conduit we characterise the distinct variations in the shear stress exerted on the upper sections of the flow tube and in the gas pressures measured above the liquid surface, during different degassing flow configurations. These signals, generated by varying styles of gas ascent, expansion and burst, can reflect field infrasonic measurements and ground motion proximal to a vent. The shear stress signals exhibit timescales and trends in qualitative agreement with the near-vent inflation-deflation cycles identified at Stromboli. Therefore, shear stress along the uppermost conduit may represent a plausible source of near-vent tilt, and conduit shear contributions should be considered in the interpretation of ground deformation, which is usually attributed to pressure sources only. The same range of flow processes can produce different experimental infrasonic waveforms, even for similar masses of gas escape. The experimental data resembled infrasonic waveforms acquired from different vents at Stromboli associated with different eruptive styles. Accurate interpretation of near-vent ground deformation, infrasonic signal and eruptive style therefore requires detailed understanding of: a) spatiotemporal magma rheology in the shallow conduit, and b) shallow conduit geometry, as well as bubble overpressure and volume.
Hidden Outgassing Dynamics at Kilauea (Hawaii) Lava Lake
NASA Astrophysics Data System (ADS)
Del Bello, E.; Taddeucci, J.; Orr, T. R.; Houghton, B. F.; Scarlato, P.; Patrick, M. R.
2014-12-01
Lava lakes offer unique opportunities for understanding how magmatic volatiles physically escape from low-viscosity, vesicular magma in open-vent conditions, a process often referred to as magma outgassing. Large-scale lava convection movements and meter-scale bubble explosions, sometimes triggered by rock falls, are acknowledged outgassing processes but may not be the only ones. In 2013 we used high-frequency (50-500 Hz) thermal and visible imaging to investigate the short-timescale dynamics of the currently active Halema`uma`u lava lake. At that time, besides the dominant release of large bubbles, three types of peculiar outgassing features were observed on the lava lake surface. The first, diffusely observed throughout the observation experiment, consisted of prolonged (up to seconds) gas venting from 'spot vents'. These vents appeared to open and close without the ejection of material or bubble bursting, and were the site of hot gas emission. Spot vents were located both between and inside cooling plates, and followed the general circulation pattern together with the rest of the lava lake surface. The second feature, observed only once, consisted of the transient wobbling of the whole lava lake surface. This wobbling, with a wavelength of meters to tens of meters, was not related to any external trigger, and dampened soon without apparent consequences on the other lake dynamics. Finally, we observed large (meters) doming areas of the lake surface randomly fluctuating over seconds to minutes. These areas were either stationary or moved independently of the general lake surface circulation, and usually were not affected by other lake surface features (e.g., cooling plate boundaries). These three features, though trivial for the overall lake outgassing, testify that the lava lake has a complex shallow subsurface architecture, in which permeable channels and gas pockets act independently of the more common bubble bursts.
NASA Astrophysics Data System (ADS)
Bryan, S. E.; Cas, R. A. F.; Martí, J.
2000-12-01
The Granadilla Member is one of the most widely dispersed and largest volume pyroclastic units at Tenerife (Canary Islands) and represents the culminating eruption to a second cycle of explosive volcanism of the Las Cañadas edifice. The member, dated at 0.57 Ma, comprises a plinian fall deposit, the Granadilla pumice, which is overlain by ignimbrite up to 30 m thick. The Granadilla pumice is up to 9 m thick approximately 10 km from source (Pyle bt value is 5.35 km), and is subdivided into four fall units. Unit 1 is up to 1.2 m thick and is further divisible into another four pumice fall subunits, based on bedding and grainsize differences. Unit 2 is a thin but distinctive ash layer (˜2 cm thick), and its wide dispersal (>550 km2), constant thickness, planar laminations and ash aggregate textures collectively indicate a phreatoplinian fall origin. The lithic-rich nature and abundance of unaltered lithic fragments reflect magma interaction with aquifer-derived water at depth. Unit 3 (≤1.8 m thick), records a reversal to dry plinian eruptive activity. Unit 4, the thickest of the fall units (up to 6.3 m thick), records the maximum dispersal and intensity of the eruption (Pyle bt and bc values are 5.7 and 6.3 km, respectively), best illustrated by the presence of large pumice bombs up to 30 cm diameter (at distances up to 20 km from vent), and reverse grading of lithic and pumice clasts. The widespread (>500 km2), nonwelded and pumice-rich Granadilla ignimbrite (unit 5) records the collapse of the plinian eruption column. The ignimbrite has a simple sheet-like geometry, but exhibits a complex internal stratigraphy. The base of the ignimbrite locally cuts down through the underlying Granadilla pumice removing it entirely, indicating up to 9 m of erosion by the pyroclastic flows. A coarse, vent-derived lithic breccia horizon towards the top of the ignimbrite is interpreted to record the onset of caldera collapse late in the eruption. Minimum volume estimates for the Granadilla pumice and ignimbrite are 5.2 and 5 km3, respectively. The dispersal area, deposit characteristics, and exponential thickness and clast size decay relationships with (isopach area)1/2 are consistent with dispersal and fallout from the umbrella region of a moderately high (˜17 to ≥25 km) plinian column. We propose that the eruption involved two vents, probably aligned along a NE-SW fissure within the Las Cañadas caldera.
History of the Magmatic Feeding System of the Campi Flegrei Caldera
NASA Astrophysics Data System (ADS)
Orsi, G.; Civetta, L.; Arienzo, I.; D'Antonio, M.; di Renzo, V.; di Vito, M. A.
2007-12-01
The definition of the magmatic feeding system of active volcanoes, in terms of composition, time-scale of crystallization, relation between composition of the erupted magma and structural position of vents, magma chamber processes and architecture, is of extreme importance for the hazard evaluation. The studies that are carried out for the definition of the magmatic systems include detailed mineralogical, geochemical and isotopic analyses (Sr, Nd, Pb). The Campi Flegrei caldera magmatic structure is characterized by deep and shallow magma chambers. In the deep reservoir (20-10 km depth) mantle derived magmas differentiate and are contaminated with continental crust. In the shallow reservoirs isotopically distinct magmas further differentiate, mix and mingle before the eruptions. These processes generated isotopically distinct components that were variably involved along different structures of the Campi Flegrei caldera during time. At Campi Flegrei caldera the relation between the structural position of the eruptive vent, for the last 14 ka of activity, and the isotopic composition of the emitted magma allow us to reconstruct the architecture of the magmatic feeding system and to infer the chemical and isotopic composition, and the magma chamber location and processes, of the future eruption, according to the position of the vent
Greenhouse gas emissions from septic systems in New York State
NASA Astrophysics Data System (ADS)
Truhlar, A. M.; Rahm, B. G.; Brooks, R. A.; Nadeau, S. A.; Walter, M. T.
2015-12-01
Onsite septic systems are a practical way to treat wastewater in rural or less-densely populated areas. Septic systems utilize microbial processes to eliminate organic wastes and nutrients such as nitrogen; these processes can contribute to air pollution through the release of greenhouse gases (GHGs). At each of nine septic systems, we measured fluxes of CH4, CO2, and N2O from the soil over the leach field and sand filter, and from the roof outlet vent. These are the most likely locations for gas emissions during normal operation of the septic system. The majority of all septic system gas emissions were released from the roof vent. However, our comparisons of the gas fluxes from these locations suggest that biological processes in the soil, especially the soil over the leach field, can influence the type and quantity of gas that is released from the system. The total vent, sand filter, and leach field GHG emissions were 0.12, 0.045, and 0.046 tonne CO2e capita-1 year-1, respectively. In total, this represents about 1.5% of the annual carbon footprint of an individual living in the US.
NASA Astrophysics Data System (ADS)
Shank, T. M.; Holden, J. F.; Herrera, S.; Munro, C.; Muric, T.; Lin, J.; Stuart, L.
2011-12-01
GALREX 2011 was a NOAA OER telepresence cruise that explored the diverse habitats and geologic settings of the deep Galápagos region. The expedition made12 Little Hercules ROV dives in July 2011.Abundant corals and a strong depth zonation of species (including deepwater coral communities) were found near 500 m depth on Paramount Seamount, likely influenced by past low sea level states, wave-cut terrace processes, and the historical presence of shallow reef structures. At fresh lava flows with associated (flocculent) hydrothermal venting near 88° W, now known as Uka Pacha and Pegasus Vent Fields, rocks were coated with white microbial mat and lacked sessile fauna, with few mobile fauna (e.g., bythograeid crabs, alvinocarid shrimp, polynoid worms, zoarcid fish, and dirivultid copepods). This suggests a recent creation of hydrothermal habitats through volcanic eruptions and/or diking events, which may have taken place over a 15 km span separating the two vent fields. The Rosebud vent field at 86°W was not observed and may have been covered with lava since last visited in 2005. A hydrothermal vent field near 86°W was discovered that is one of the largest vent fields known on the Rift (120m by 40m). Low-temperature vent habitats were colonized by low numbers of tubeworms including Riftia, Oasisia, and a potential Tevnia species (the latter not previously observed on the Galapagos Rift). Patches of tubeworms were observed with individuals less than 2cm in length, and the relatively few large Riftia had tube lengths near 70cm long. Large numbers of small (< 3cm long) bathymodiolin mussels lined cracks and crevices throughout the active part of the field. Live clams, at least four species of gastropod limpets, three species of polynoid polychaetes, juvenile and adult alvinocarid shrimp, actinostolid anemones, and white microbial communities were observed on the underside and vertical surfaces of basalt rock surfaces. There were at least 13 species of vent-endemic fauna. The active colonization was observed on relatively older basalt pillows and lobate lavas ringed by and amidst a large dead bed of Calyptogena clams (most with broken and dissolving shells greater than 25 cm in length, with a few of the same size living amongst the dissolving shells). Scattered pockets of living adult mussels were observed among these dead clams. The margins of the field were ringed with large numbers of dandelion siphonophores. This field, named Tempus Fugit Vent Field, was once a massive clam bed (> 20 years old) and now, while hosting mature mussel communities and adult clams (> 2 years old), is being actively colonized by vent-endemic fauna that can be considered to be recent arrivals and colonizers (less than a few months) at Galapagos vent fields. These findings not only provide strong evidence of recent volcanic activity between 85° W and 88° W on the Galapagos Rift, but provide evidence that the rates of hydrothermal habitat turnover via eruption, dike injection, or venting cessation may be considerably higher than previously thought along the Galápagos Rift.
14 CFR 23.975 - Fuel tank vents and carburetor vapor vents.
Code of Federal Regulations, 2012 CFR
2012-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System § 23.975 Fuel tank vents and carburetor vapor vents. (a) Each fuel tank must be vented... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fuel tank vents and carburetor vapor vents...
14 CFR 23.975 - Fuel tank vents and carburetor vapor vents.
Code of Federal Regulations, 2011 CFR
2011-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System § 23.975 Fuel tank vents and carburetor vapor vents. (a) Each fuel tank must be vented... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fuel tank vents and carburetor vapor vents...
14 CFR 23.975 - Fuel tank vents and carburetor vapor vents.
Code of Federal Regulations, 2014 CFR
2014-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System § 23.975 Fuel tank vents and carburetor vapor vents. (a) Each fuel tank must be vented... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fuel tank vents and carburetor vapor vents...
14 CFR 23.975 - Fuel tank vents and carburetor vapor vents.
Code of Federal Regulations, 2013 CFR
2013-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System § 23.975 Fuel tank vents and carburetor vapor vents. (a) Each fuel tank must be vented... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fuel tank vents and carburetor vapor vents...
14 CFR 23.975 - Fuel tank vents and carburetor vapor vents.
Code of Federal Regulations, 2010 CFR
2010-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System § 23.975 Fuel tank vents and carburetor vapor vents. (a) Each fuel tank must be vented... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel tank vents and carburetor vapor vents...
Development of an atmospheric monitoring plan for space station
NASA Technical Reports Server (NTRS)
Casserly, Dennis M.
1989-01-01
An environmental health monitoring plan for Space Station will ensure crew health during prolonged habitation. The Space Station, Freedom, will operate for extended periods, 90+ days, without resupply. A regenerative, closed loop life support system will be utilized in order to minimize resupply logistics and costs. Overboard disposal of wastes and venting of gases to space will be minimal. All waste material will be treated and recycled. The concentrated wastes will be stabilized and stored for ground disposal. The expected useful life of the station (decades) and the diversity of materials brought aboard for experimental or manufacturing purposes, increases the likelihood of cabin contamination. Processes by which cabin contamination can occur include: biological waste production, material off-gassing, process leakage, accidental containment breach, and accumulation due to poor removal efficiencies of the purification units. An industrial hygiene approach was taken to rationalize monitoring needs and to identify the substances likely to be present, the amount, and their hazard.
24 CFR 3280.611 - Vents and venting.
Code of Federal Regulations, 2013 CFR
2013-04-01
...) Size of vent piping—(1) Main vent. The drain piping for each toilet shall be vented by a 11/2 inch... venting cross section of a 11/2 inch diameter vent, connected to the toilet drain by one of the following... toilet drain within the distance allowed in § 3280.611(c)(5), for 3-inch trap arms undiminished in size...
24 CFR 3280.611 - Vents and venting.
Code of Federal Regulations, 2012 CFR
2012-04-01
...) Size of vent piping—(1) Main vent. The drain piping for each toilet shall be vented by a 11/2 inch... venting cross section of a 11/2 inch diameter vent, connected to the toilet drain by one of the following... toilet drain within the distance allowed in § 3280.611(c)(5), for 3-inch trap arms undiminished in size...
Lithic breccia and ignimbrite erupted during the collapse of Crater Lake Caldera, Oregon
Druitt, T.H.; Bacon, C.R.
1986-01-01
The climactic eruption of Mount Mazama (6845 y.B.P.) vented a total of ???50 km3 of compositionally zoned rhyodacitic to basaltic magma from: (a) a single vent as a Plinian pumice fall deposit and the overlying Wineglass Welded Tuff, and (b) ring vents as ignimbrite and coignimbrite lithic breccia accompanying the collapse of Crater Lake caldera. New field and grain-size data for the ring-vent products are presented in this report. The coarse-grained, poorly bedded, clast-supported lithic breccia extends as far as 18 km from the caldera center. Like the associated ignimbrite, the breccia is compositionally zoned both radially and vertically, and silicic, mixed, and mafic types can be recognized, based on the proportion of rhyodacitic pumice. Matrix fractions in silicic breccias are depleted of fines and are lithic- and crystal-enriched relative to silicic ignimbrite due to vigorous gas sorting during emplacement. Ignimbrite occurs as a proximal veneer deposit overlying the breccia, a medial (??? 8 to ??? 25 km from the caldera center), compositionally zoned valley fill as much as > 110 m thick, and an unzoned distal ({slanted equal to or greater-than} 20 km) facies which extends as far as 55 km from the caldera. Breccia within ??? 9 km of the caldera center is interpreted as a coignimbrite lag breccia formed within the deflation zone of the collapsing ring-vent eruption columns. Expanded pyroclastic flows of the deflation zone were probably vertically graded in both size and concentration of blocks, as recently postulated for some turbidity currents. An inflection in the rate of falloff of lithic-clast size within the lithic breccia at ??? 9 km may mark the outer edge of the deflation zone or may be an artifact of incomplete exposure. The onset of ring-vent activity at Mt. Mazama was accompanied by a marked increase in eruptive discharge. Pyroclastic flows were emplaced as a semicontinuous stream, as few ignimbrite flow-unit boundaries are evident. As eruption from the ring vents progressed, flow-runout distance and the extent of breccia deposition decreased due to (a) greater internal flow friction, and (b) decreasing eruption column heights. Effect (b) probably resulted from a progressive decrease in magmatic gas content and discharge rate. Waning discharge may have been promoted by the tapping of more viscous, crystal-rich magma, collapse of conduit walls, and declining caldera collapse rate. ?? 1986.
40 CFR 63.132 - Process wastewater provisions-general.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 10 2014-07-01 2014-07-01 false Process wastewater provisions-general... Manufacturing Industry for Process Vents, Storage Vessels, Transfer Operations, and Wastewater § 63.132 Process wastewater provisions—general. (a) Existing sources. This paragraph specifies the requirements applicable to...
40 CFR 63.147 - Process wastewater provisions-recordkeeping.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 10 2012-07-01 2012-07-01 false Process wastewater provisions... Manufacturing Industry for Process Vents, Storage Vessels, Transfer Operations, and Wastewater § 63.147 Process wastewater provisions—recordkeeping. (a) The owner or operator transferring a Group 1 wastewater stream or...
40 CFR 63.132 - Process wastewater provisions-general.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 10 2013-07-01 2013-07-01 false Process wastewater provisions-general... Manufacturing Industry for Process Vents, Storage Vessels, Transfer Operations, and Wastewater § 63.132 Process wastewater provisions—general. (a) Existing sources. This paragraph specifies the requirements applicable to...
40 CFR 63.132 - Process wastewater provisions-general.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Process wastewater provisions-general... Manufacturing Industry for Process Vents, Storage Vessels, Transfer Operations, and Wastewater § 63.132 Process wastewater provisions—general. (a) Existing sources. This paragraph specifies the requirements applicable to...
40 CFR 63.132 - Process wastewater provisions-general.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 10 2012-07-01 2012-07-01 false Process wastewater provisions-general... Manufacturing Industry for Process Vents, Storage Vessels, Transfer Operations, and Wastewater § 63.132 Process wastewater provisions—general. (a) Existing sources. This paragraph specifies the requirements applicable to...
40 CFR 63.147 - Process wastewater provisions-recordkeeping.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 10 2014-07-01 2014-07-01 false Process wastewater provisions... Manufacturing Industry for Process Vents, Storage Vessels, Transfer Operations, and Wastewater § 63.147 Process wastewater provisions—recordkeeping. (a) The owner or operator transferring a Group 1 wastewater stream or...
40 CFR 63.134 - Process wastewater provisions-surface impoundments.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Process wastewater provisions-surface... Manufacturing Industry for Process Vents, Storage Vessels, Transfer Operations, and Wastewater § 63.134 Process wastewater provisions—surface impoundments. (a) For each surface impoundment that receives, manages, or...
40 CFR 63.147 - Process wastewater provisions-recordkeeping.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 10 2013-07-01 2013-07-01 false Process wastewater provisions... Manufacturing Industry for Process Vents, Storage Vessels, Transfer Operations, and Wastewater § 63.147 Process wastewater provisions—recordkeeping. (a) The owner or operator transferring a Group 1 wastewater stream or...
40 CFR 63.147 - Process wastewater provisions-recordkeeping.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 9 2011-07-01 2011-07-01 false Process wastewater provisions... Manufacturing Industry for Process Vents, Storage Vessels, Transfer Operations, and Wastewater § 63.147 Process wastewater provisions—recordkeeping. (a) The owner or operator transferring a Group 1 wastewater stream or...
40 CFR 63.132 - Process wastewater provisions-general.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 9 2011-07-01 2011-07-01 false Process wastewater provisions-general... Manufacturing Industry for Process Vents, Storage Vessels, Transfer Operations, and Wastewater § 63.132 Process wastewater provisions—general. (a) Existing sources. This paragraph specifies the requirements applicable to...
Experimentally Testing Hydrothermal Vent Origin of Life on Enceladus and Other Icy/Ocean Worlds.
Barge, Laura M; White, Lauren M
2017-09-01
We review various laboratory strategies and methods that can be utilized to simulate prebiotic processes and origin of life in hydrothermal vent systems on icy/ocean worlds. Crucial steps that could be simulated in the laboratory include simulations of water-rock chemistry (e.g., serpentinization) to produce hydrothermal fluids, the types of mineral catalysts and energy gradients produced in vent interfaces where hydrothermal fluids interface with the surrounding seawater, and simulations of biologically relevant chemistry in flow-through gradient systems (i.e., far-from-equilibrium experiments). We describe some examples of experimental designs in detail, which are adaptable and could be used to test particular hypotheses about ocean world energetics or mineral/organic chemistry. Enceladus among the ocean worlds provides an ideal test case, since the pressure at the ocean floor is more easily simulated in the lab. Results for Enceladus could be extrapolated with further experiments and modeling to understand other ocean worlds. Key Words: Enceladus-Ocean worlds-Icy worlds-Hydrothermal vent-Iron sulfide-Gradient. Astrobiology 17, 820-833.
Xu, Hongxiu; Jiang, Lijing; Li, Shaoneng; Zhong, Tianhua; Lai, Qiliang; Shao, Zongze
2016-01-04
To investigate the diversity of culturable sulfur-oxidizing bacteria in hydrothermal vent environments of the South Atlantic, and analyze their characteristics of sulfur oxidation. We enriched and isolated sulfur-oxidizing bacteria from hydrothermal vent samples collected from the South Atlantic. The microbial diversity in enrichment cultures was analyzed using the Denatural Gradient Gel Electrophoresis method. Sulfur-oxidizing characteristics of the isolates was further studied by using ion chromatography. A total of 48 isolates were obtained from the deep-sea hydrothermal vent samples, which belonged to 23 genera and mainly grouped into alpha-Proteobacteria (58.3%), Actinobacteria (22.9%) and gama-Proteobacteria (18.8%). Among them, the genus Thalassospira, Martelella and Microbacterium were dominant. About 60% of the isolates exibited sulfur-oxidizing ability and strain L6M1-5 had a higher sulfur oxidation rate by comparison analysis. The diversity of sulfur-oxidizing bacteria in hydrothermal environments of the South Atlantic was reported for the first time based on culture-dependent methods. The result will help understand the biogechemical process of sulfur compounds in the deep-sea hydrothermal environments.
Development of a 3D Filling Model of Low-Pressure Die-Cast Aluminum Alloy Wheels
NASA Astrophysics Data System (ADS)
Duan, Jianglan; Maijer, Daan; Cockcroft, Steve; Reilly, Carl
2013-12-01
A two-phase computational fluid dynamics model of the low-pressure die-cast process for the production of A356 aluminum alloy wheels has been developed to predict the flow conditions during die filling. The filling model represents a 36-deg section of a production wheel, and was developed within the commercial finite-volume package, ANSYS CFX, assuming isothermal conditions. To fully understand the behavior of the free surface, a novel technique was developed to approximate the vent resistances as they impact on the development of a backpressure within the die cavity. The filling model was first validated against experimental data, and then was used to investigate the effects of venting conditions and pressure curves during die filling. It was found that vent resistance and vent location strongly affected die filling time, free surface topography, and air entrainment for a given pressure fill-curve. With regard to the pressure curve, the model revealed a strong relation between the pressure curve and the flow behavior in the hub, which is an area prone to defect formation.
Sulphur isotopic compositions of deep-sea hydrothermal vent animals
NASA Technical Reports Server (NTRS)
Fry, B.; Gest, H.; Hayes, J. M.
1983-01-01
The S-34/S-32 ratios of tissues from vestimentiferan worms, brachyuran crabs, and giant clams living around deep hydrothermal vents are reported. Clean tissues were dried, ground, suspended in 0.1 M LiCl, shaken twice at 37 C to remove seawater sulfates, dried at 60 C, combusted in O2 in a Parr bomb. Sulfur was recovered as BaSO4, and the isotopic abundances in SO2 generated by thermal decomposition of 5-30-mg samples were determined using an isotope-ratio mass spectrometer. The results are expressed as delta S-34 and compared with values measured in seawater sulfates and in normal marine fauna. The values ranged from -4.7 to 4.7 per thousand, comparable to vent sulfide minerals (1.3-4.1 per thousand) and distinct from seawater sulfates (20.1 per thousand) and normal marine fauna (about 13-20 per thousand). These results indicate that vent sulfur rather than seawater sulfur is utilized by these animals, a process probably mediated by chemoautotrophic bacteria which can use inorganic sulfur compounds as energy sources.
40 CFR 65.44 - External floating roof (EFR).
Code of Federal Regulations, 2013 CFR
2013-07-01
... external floating roof except for automatic bleeder vents (vacuum breaker vents) and rim space vents does... floating roof shall meet the following specifications: (i) Except for automatic bleeder vents (vacuum breaker vents) and rim space vents, each opening in the noncontact external floating roof shall provide a...
40 CFR 65.44 - External floating roof (EFR).
Code of Federal Regulations, 2014 CFR
2014-07-01
... external floating roof except for automatic bleeder vents (vacuum breaker vents) and rim space vents does... floating roof shall meet the following specifications: (i) Except for automatic bleeder vents (vacuum breaker vents) and rim space vents, each opening in the noncontact external floating roof shall provide a...
40 CFR 65.44 - External floating roof (EFR).
Code of Federal Regulations, 2012 CFR
2012-07-01
... external floating roof except for automatic bleeder vents (vacuum breaker vents) and rim space vents does... floating roof shall meet the following specifications: (i) Except for automatic bleeder vents (vacuum breaker vents) and rim space vents, each opening in the noncontact external floating roof shall provide a...
NASA Astrophysics Data System (ADS)
Garcia-Pineda, O. G.; MacDonald, I. R.; Shedd, W.; Zimmer, B.
2009-12-01
Analysis of natural hydrocarbon seeps is important to improve our understanding of methane flux from deeper sediments to the water column. In order to quantify natural hydrocarbon seep formations in the Northern Gulf of Mexico, a set of 686 Synthetic Aperture Radar (SAR) images was analyzed using the Texture Classifying Neural Network Algorithm (TCNNA), which processes SAR data to delineate oil slicks. This analysis resulted in a characterization of 396 natural seep sites distributed in the northern GOM. Within these sites, a maximum of 1248 individual vents where identified. Oil reaching the sea-surface is deflected from its source during transit through the water column. This presentation describes a method for estimating locations of active oil vents based on repeated slick detection in SAR. One of the most active seep formations was detected in MMS lease block GC600. A total of 82 SAR scenes (collected by RADARSAT-1 from 1995 to 2007) was processed covering this region. Using TCNNA the area covered by each slick was computed and Oil Slicks Origins (OSO) were selected as single points within detected oil slicks. At this site, oil slick signatures had lengths up to 74 km and up to 27 km^2 of area. Using SAR and TCNNA, four active vents were identified in this seep formation. The geostatistical mean centroid among all detections indicated a location along a ridge-line at ~1200m. Sea truth observations with an ROV, confirmed that the estimated location of vents had a maximum offset of ~30 m from their actual locations on the seafloor. At the largest vent, a 3-m high, 12-m long mound of oil-saturated gas hydrate was observed. The outcrop contained thousands of ice worms and numerous semi-rigid chimneys from where oily bubbles were escaping in a continuous stream. Three additional vents were found along the ridge; these had lower apparent flow, but were also plugged with gas hydrate mounds. These results support use of SAR data for precise delineation of active seep formation and shallow gas hydrate deposits.
NASA Astrophysics Data System (ADS)
Hoffert, M.; Anderson, R. E.; Stepanauskas, R.; Huber, J. A.
2017-12-01
Deep-sea hydrothermal vents sustain diverse communities of microorganisms. The effects of geochemical and biological interactions on the process of evolution in these ecosystems remains poorly understood because the majority of subsurface microorganisms remain uncultivated. By examining metagenomic samples from hydrothermal fluids and mapping the samples to closely-related genomes found in vent sites, we can better understand how the process of evolution is affected by the geochemical and environmental context in deep-sea vents. The Mid-Cayman Rise is a spreading ridge that hosts both mafic-influenced and ultramafic-influenced vent fields. Previous research on metagenomic samples from sites in the Mid-Cayman Rise has shown that these vents contain metabolically and taxonomically diverse microbial communities. Here, we investigate five single cell amplified Methanothermococcus genomes (SAGs) to investigate patterns in pangenomic variation and molecular evolution in these methanogens. Mappings of metagenomic reads from 15 sample sites to the SAGs reveal substantial variation in Methanothermococcus population abundance, nucleotide variability and selection pressure among the 15 geochemically distinct sample sites. Within each sample site, we observed distinct patterns of single nucleotide variant (SNV) accumulation and selection pressure within the SAG populations. Closely related genomes showed similar patterns of SNV accumulation. Analysis of open reading frames (ORFs) from the SAGs indicated that homologous genes accumulated variation at the same rate. For example, a genomic island for Nif genes was identified in three of the five genomes with significantly elevated SNV counts. dN/dS analyses revealed evidence for frequency-dependent selection, in which genes unique to individual SAGs displayed elevated diversifying selection relative to other genes. These results indicate that different strains of Methanothermococcus outcompete others in specific environmental settings, and that these fitness advantages may result from variation in the pangenome, as revealed by dN/dS and SNV analyses. By examining variation and the scale of nucleotide and genes, we aim to gain insight into the roles of genetic diversity and environmental selection on microbial evolution in these ecosystems.
Back to the Future: Integrated Air and Missile Defense in the Pacific
2015-02-01
US assets with those of our allies and partners, we have optimized our defense design, pre- venting the waste of precious interceptors. The Pacific...Good Offense: Attack Operations Power projection is, and always will be, th e bread and butter of the US Air Force. Only the United States can
Code of Federal Regulations, 2010 CFR
2010-07-01
... system to measure and record the opacity of emissions from each catalyst regnerator vent. 4. Option 3: Ni... monitoring system to measure and record the gas flow rate 1. 5. Option 4: Ni lb/1,000 lbs of coke burn-off...
Code of Federal Regulations, 2011 CFR
2011-07-01
... system to measure and record the opacity of emissions from each catalyst regnerator vent. 4. Option 3: Ni... monitoring system to measure and record the gas flow rate 1. 5. Option 4: Ni lb/1,000 lbs of coke burn-off...
Code of Federal Regulations, 2010 CFR
2010-07-01
... organic compounds (TOC) means those compounds measured according to the procedures in § 60.664(b)(4). For... required in § 60.664(d)(5) and § 60.664(e); and TOC concentration as required in § 60.665(b)(4) and § 60... total resource requirement per unit reduction of TOC associated with an individual distillation vent...
Shen, Xiao; Dojcinovic, Danijel; Baldi, Lucia; Hacker, David L; Luescher, Immanuel F; Wurm, Florian M
2018-01-01
To investigate the effects of operational process conditions on expression of MHC class II protein from a stable Drosophila S2 cell line. When the Drosophila S2 cells were grown in vented orbitally shaken TubeSpin bioreactor 600 containers, cell growth was improved three-fold and the yield of recombinant major histocompatibility (MHC) class II protein (HLA-DR1 2xHis ) increased four-fold over the levels observed for the same cells cultivated in roller bottles (RB) without vented caps. Culturing in RB with vented caps while increasing the rotation speed from 6 rpm to 18 rpm also improved cell growth five-fold and protein productivity three-fold which is comparable to the levels observed in the orbitally shaken containers. Protein activity was found to be almost identical between the two vessel systems tested. Optimized cell culture conditions and a more efficient vessel type can enhance gas transfer and mixing and lead to substantial improvement of recombinant product yields from S2 cells.
Diffuse versus discrete venting at the Tour Eiffel vent site, Lucky Strike hydrothermal field
NASA Astrophysics Data System (ADS)
Mittelstaedt, E. L.; Escartin, J.; Gracias, N.; Olive, J. L.; Barreyre, T.; Davaille, A. B.; Cannat, M.
2010-12-01
Two styles of fluid flow at the seafloor are widely recognized: (1) localized outflows of high temperature (>300°C) fluids, often black or grey color in color (“black smokers”) and (2) diffuse, lower temperature (<100°C), fluids typically transparent and which escape through fractures, porous rock, and sediment. The partitioning of heat flux between these two types of hydrothermal venting is debated and estimates of the proportion of heat carried by diffuse flow at ridge axes range from 20% to 90% of the total axial heat flux. Here, we attempt to improve estimates of this partitioning by carefully characterizing the heat fluxes carried by diffuse and discrete flows at a single vent site, Tour Eiffel in the Lucky Strike hydrothermal field along the Mid-Atlantic Ridge. Fluid temperature and video data were acquired during the recent Bathyluck’09 cruise to the Lucky Strike hydrothermal field (September, 2009) by Victor aboard “Pourquoi Pas?” (IFREMER, France). Temperature measurements were made of fluid exiting discrete vents, of diffuse effluents immediately above the seafloor, and of vertical temperature gradients within discrete hydrothermal plumes. Video data allow us to calculate the fluid velocity field associated with these outflows: for diffuse fluids, Diffuse Flow Velocimetry tracks the displacement of refractive index anomalies through time; for individual hydrothermal plumes, Particle Image Velocimetry tracks eddies by cross-correlation of pixels intensities between subsequent images. Diffuse fluids exhibit temperatures of 8-60°C and fluid velocities of ~1-10 cm s-1. Discrete outflows at 204-300°C have velocities of ~1-2 m s-1. Combined fluid flow velocities, temperature measurements, and full image mosaics of the actively venting areas are used to estimate heat flux of both individual discrete vents and diffuse outflow. The total integrated heat flux and the partitioning between diffuse and discrete venting at Tour Eiffel, and its implications for the nature of hydrothermal activity across the Lucky Strike site are discussed along with the implications for crustal permeability, associated ecosystems, and mid-ocean ridge processes.
Occupancy-driven smart register for building energy saving (Conference Presentation)
NASA Astrophysics Data System (ADS)
Chen, Zhangjie; Wang, Ya S.
2017-04-01
The new era in energy-efficiency building is to integrate automatic occupancy detection with automated heating, ventilation and cooling (HVAC), the largest source of building energy consumption. By closing off some air vents, during certain hours of the day, up to 7.5% building energy consumption could be saved. In the past, smart vent has received increasing attention and several products have been developed and introduced to the market for building energy saving. For instance, Ecovent Systems Inc. and Keen Home Inc. have both developed smart vent registers capable of turning the vent on and off through smart phone apps. However, their products do not have on-board occupancy sensors and are therefore open-loop. Their vent control was achieved by simply positioning the vent blade through a motor and a controller without involving any smart actuation. This paper presents an innovative approach for automated vent control and automatic occupancy (human subjects) detection. We devise this approach in a smart register that has polydimethylsiloxane (PDMS) frame with embedded Shape memory alloy (SMA) actuators. SMAs belong to a class of shape memory materials (SMMs), which have the ability to `memorise' or retain their previous form when subjected to certain stimulus such as thermomechanical or magnetic variations. And it can work as actuators and be applied to vent control. Specifically, a Ni-Ti SMA strip will be pre-trained to a circular shape, wrapped with a Ni-Cr resistive wire that is coated with thermally conductive and electrically isolating material. Then, the SMA strip along with an antagonistic SMA strip will be bonded with PZT sensor and thermal sensors, to be inserted into a 3D printed mould which will be filled with silicone rubber materials. In the end, a demoulding process yields a fully integrated blade of the smart register. Several blades are installed together to form the smart register. The PZT sensors can feedback the shape of the actuator for precise shape and air flow control. The performance and the specification of the smart registers will be characterized experimentally. Its capacity of regulating airflow, forming air curtain will be demonstrated.
24 CFR 3280.611 - Vents and venting.
Code of Federal Regulations, 2014 CFR
2014-04-01
... drain piping for each toilet shall be vented by a 11/2 inch minimum diameter vent or rectangular vent of..., connected to the toilet drain by one of the following methods: (i) A 11/2 inch diameter (min.) individual vent pipe or equivalent directly connected to the toilet drain within the distance allowed in § 3280...
40 CFR 63.133 - Process wastewater provisions-wastewater tanks.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 10 2014-07-01 2014-07-01 false Process wastewater provisions-wastewater tanks. 63.133 Section 63.133 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Chemical Manufacturing Industry for Process Vents, Storage Vessels, Transfer Operations, and Wastewater...
40 CFR 63.133 - Process wastewater provisions-wastewater tanks.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 10 2012-07-01 2012-07-01 false Process wastewater provisions-wastewater tanks. 63.133 Section 63.133 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Chemical Manufacturing Industry for Process Vents, Storage Vessels, Transfer Operations, and Wastewater...
40 CFR 63.133 - Process wastewater provisions-wastewater tanks.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 9 2011-07-01 2011-07-01 false Process wastewater provisions-wastewater tanks. 63.133 Section 63.133 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Chemical Manufacturing Industry for Process Vents, Storage Vessels, Transfer Operations, and Wastewater...
40 CFR 63.133 - Process wastewater provisions-wastewater tanks.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 10 2013-07-01 2013-07-01 false Process wastewater provisions-wastewater tanks. 63.133 Section 63.133 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Chemical Manufacturing Industry for Process Vents, Storage Vessels, Transfer Operations, and Wastewater...
Mineralization of Alvinella polychaete tubes at hydrothermal vents.
Georgieva, M N; Little, C T S; Ball, A D; Glover, A G
2015-03-01
Alvinellid polychaete worms form multilayered organic tubes in the hottest and most rapidly growing areas of deep-sea hydrothermal vent chimneys. Over short periods of time, these tubes can become entirely mineralized within this environment. Documenting the nature of this process in terms of the stages of mineralization, as well as the mineral textures and end products that result, is essential for our understanding of the fossilization of polychaetes at hydrothermal vents. Here, we report in detail the full mineralization of Alvinella spp. tubes collected from the East Pacific Rise, determined through the use of a wide range of imaging and analytical techniques. We propose a new model for tube mineralization, whereby mineralization begins as templating of tube layer and sublayer surfaces and results in fully mineralized tubes comprised of multiple concentric, colloform, pyrite bands. Silica appeared to preserve organic tube layers in some samples. Fine-scale features such as protein fibres, extracellular polymeric substances and two types of filamentous microbial colonies were also found to be well preserved within a subset of the tubes. The fully mineralized Alvinella spp. tubes do not closely resemble known ancient hydrothermal vent tube fossils, corroborating molecular evidence suggesting that the alvinellids are a relatively recent polychaete lineage. We also compare pyrite and silica preservation of organic tissues within hydrothermal vents to soft tissue preservation in sediments and hot springs. © 2014 The Authors. Geobiology Published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Ji, Fuwu; Zhou, Huaiyang; Yang, Qunhui; Gao, Hang; Wang, Hu; Lilley, Marvin D.
2017-04-01
The Longqi hydrothermal field at 49.6°E on the Southwest Indian Ridge was the first active hydrothermal field found at a bare-rock ultra-slow spreading mid-ocean ridge. Here we report the chemistry of the hydrothermal fluids, for the first time, that were collected from the S zone and the M zone of the Longqi field by gas-tight isobaric samplers by the HOV "Jiaolong" diving cruise in January 2015. According to H2, CH4 and other chemical data of the vent fluid, we suggest that the basement rock at the Longqi field is dominantly mafic. This is consistent with the observation that the host rock of the active Longqi Hydrothermal field is dominated by extensively distributed basaltic rock. It was very interesting to detect simultaneously discharging brine and vapor caused by phase separation at vents DFF6, DFF20, and DFF5 respectively, in a distance of about 400 m. Based on the end-member fluid chemistry and distance between the vents, we propose that there is a single fluid source at the Longqi field. The fluid branches while rising to the seafloor, and two of the branches reach S zone and M zone and phase separate at similar conditions of about 28-30.2 MPa and 400.6-408.3 °C before they discharge from the vents. The end-member fluid compositions of these vents are comparable with or within the range of variation of known global seafloor hydrothermal fluid chemical data from fast, intermediate and slow spreading ridges, which confirms that the spreading rate is not the key factor that directly controls hydrothermal fluid chemistry. The composition of basement rock, water-rock interaction and phase separation are the major factors that control the composition of the vent fluids in the Longqi field.