Sample records for unit water lines

  1. 9 CFR 381.305 - Equipment and procedures for heat processing systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... control unit. A nonreturn valve shall be provided in the air supply line to prevent water from entering... control unit. A nonreturn valve shall be provided in the air supply line to prevent water from entering... supply of clean, dry air. The recorder timing mechanism shall be accurate. (i) Chart-type devices...

  2. 9 CFR 318.305 - Equipment and procedures for heat processing systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... control unit. A nonreturn valve shall be provided in the air supply line to prevent water from entering... control unit. A nonreturn valve shall be provided in the air supply line to prevent water from entering... ensure a supply of clean, dry air. The recorder timing mechanism shall be accurate. (i) Chart-type...

  3. 9. UNIT 4, 'DOG HOLE' IN TURBINE, SHOWING LUBRICATING LINES ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. UNIT 4, 'DOG HOLE' IN TURBINE, SHOWING LUBRICATING LINES ENTERING TURBINE BEARING HOUSING THROUGH FORMER 'SIGHT GLASSES,' WITH OVERFLOW/RETURN OIL PIPE (CENTER FOREGROUND) - Washington Water Power Company Monroe Street Plant, Units 4 & 5, South Bank Spokane River, below Monroe Street Bridge, Spokane, Spokane County, WA

  4. 46 CFR 42.50-5 - International load line certificates.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...) __ (inches) (WNA) __ (inches) below (S). Allowance for fresh water for all freeboards __ (inches). (All... point of departure and the sea. 2. When a ship is in fresh water of unit density, the appropriate load line may be submerged by the amount of the fresh water allowance shown above. Where the density is...

  5. 46 CFR 42.50-15 - Coastwise load line certificates for U.S.-flag vessels.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... center of ring. Winter __ (inches) (W) __ (inches) below (S). Allowance for fresh water for all... point of departure and the sea. 2. When a ship is in fresh water of unit density the appropriate load line may be submerged by the amount of the fresh water allowance shown above. Where the density is...

  6. 40 CFR 63.961 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... access lid or hatch), or automatically operated (e.g., a spring-loaded pressure relief valve). Hard... includes hard-piping, all drains and junction boxes, together with their associated sewer lines and other... management units include containers, air flotation units, oil-water separators or organic-water separators...

  7. 40 CFR 63.961 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... access lid or hatch), or automatically operated (e.g., a spring-loaded pressure relief valve). Hard... includes hard-piping, all drains and junction boxes, together with their associated sewer lines and other... management units include containers, air flotation units, oil-water separators or organic-water separators...

  8. 40 CFR 63.961 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... access lid or hatch), or automatically operated (e.g., a spring-loaded pressure relief valve). Hard... includes hard-piping, all drains and junction boxes, together with their associated sewer lines and other... management units include containers, air flotation units, oil-water separators or organic-water separators...

  9. 40 CFR 63.1423 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (subpart F) Incinerator (subpart G) Major source (subpart A) Malfunction (subpart A) Oil-water separator or organic-water separator (subpart G) Open-ended valve or line (subpart H) Operating permit (subpart F... process unit consists of more than one unit operation. This collection of equipment includes purification...

  10. 40 CFR 63.1423 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (subpart F) Incinerator (subpart G) Major source (subpart A) Malfunction (subpart A) Oil-water separator or organic-water separator (subpart G) Open-ended valve or line (subpart H) Operating permit (subpart F... process unit consists of more than one unit operation. This collection of equipment includes purification...

  11. Detection of oral streptococci in dental unit water lines after therapy with air turbine handpiece: biological fluid retraction more frequent than expected.

    PubMed

    Petti, Stefano; Moroni, Catia; Messano, Giuseppe Alessio; Polimeni, Antonella

    2013-03-01

    Oral streptococci detected in water from dental unit water lines (DUWLs) are a surrogate marker of patients' biological fluid retraction during therapy. We investigated oral streptococci detection rate in DUWLs in a representative sample of private offices in real-life conditions. Samples of nondisinfected water (100 ml) were collected from the DUWL designated for the air turbine handpiece in 81 dental units, immediately after dental treatment of patients with extensive air turbine handpiece use. Water was filtered and plated on a selective medium for oral streptococci and, morphologically, typical colonies of oral streptococci were counted. The lowest detection limit was 0.01 CFU/ml. The oral streptococci detection rate was 72% (95% CI: 62-81%), with a mean level of 0.7 CFU/ml. Oral streptococci detection was not affected by handpiece age or dental treatment type, but was associated with dental unit age. Biological fluid retraction into DUWLs during patient treatment and, possibly, the risk for patient-to-patient blood- or air-borne pathogen transmission are more frequent than expected.

  12. Contamination of dental unit water and air outlets following use of clean head system and conventional handpieces.

    PubMed

    Toomarian, Lida; Rikhtegaran, Sahand; Sadighi, Mehrnoosh; Savadi Oskoee, Siavash; Alizadeh Oskoee, Parnian

    2007-01-01

    Dental handpiece is a source of contamination because it is in constant touch with the oral cavity. Sterilization does not seem to be sufficient to prevent penetration of microorganisms into air and water lines of the unit, because negative pressure developed by valves (which are placed in water outlets) and post shut-off inertial rotation of handpiece result in water and debris being sucked into air and water outlets of dental unit. The aim of this study was to compare dental unit contamination following use of clean head system handpieces and conventional handpieces. Twenty-two dental units in the Department of Pediatric Dentistry in Shahid Beheshti Faculty of Dentistry were used for the purpose of this study. A 1.5×108 cfu/mm3 concentration of Staphylococcus epidermis (SE) was used to contaminate the air and water outlets of dental units. Ten clean head system handpieces and 10 conventional handpieces were used for 30 seconds in the above-mentioned suspension. Microbial samples were collected from the air and water lines. Culturing and colony counting procedures were carried out. Data was analyzed by t-test; a value of p<0.01 was considered significant. Results demonstrated a significantly lower SE contamination in water outlets following the use of clean head system (p<0.01). A lower tendency of clean head system handpieces to transmit SE compared to conventional system makes them a better choice for infection control.

  13. Economic comparison of conventional maintenance and electrochemical oxidation to warrant water safety in dental unit water lines.

    PubMed

    Fischer, Sebastian; Meyer, Georg; Kramer, Axel

    2012-01-01

    In preparation for implementation of a central water processing system at a dental department, we analyzed the costs of conventional decentralized disinfection of dental units against a central water treatment concept based on electrochemical disinfection. The cost evaluation included only the costs of annually required antimicrobial consumables and additional water usage of a decentralize conventional maintenance system for dental water lines build in the respective dental units and the central electrochemical water disinfection system, BLUE SAFETY™ Technologies. In total, analysis of costs of 6 dental departments reviled additional annual costs for hygienic preventive measures of € 4,448.37. For the BLUE SAFETY™ Technology, the additional annual total agent consumption costs were € 2.18, accounting for approximately 0.05% of the annual total agent consumption costs of the conventional maintenance system. For both water processing concepts, the additional costs for energy could not be calculated, since the required data was not obtainable from the manufacturers. For both concepts, the investment and maintenance costs were not calculated due to lack of manufacturer's data. Therefore, the results indicate the difference of costs for the required consumables only. Aside of the significantly lower annual costs for required consumables and disinfectants; a second advantage for the BLUE SAFETY™ Technology is its constant and automatic operation, which does not require additional staff resources. This not only safety human resources, but add additionally to cost saving. Since the antimicrobial disinfection capacity of the BLUE SAFETY™ was demonstrated previously and is well known, this technology, which is comparable or even superior in its non-corrosive effect, may be regarded as method of choice for continuous disinfection and prevention of biofilm formation in dental units' water lines.

  14. Water Filter

    NASA Technical Reports Server (NTRS)

    1982-01-01

    A compact, lightweight electrolytic water sterilizer available through Ambassador Marketing, generates silver ions in concentrations of 50 to 100 parts per billion in water flow system. The silver ions serve as an effective bactericide/deodorizer. Tap water passes through filtering element of silver that has been chemically plated onto activated carbon. The silver inhibits bacterial growth and the activated carbon removes objectionable tastes and odors caused by addition of chlorine and other chemicals in municipal water supply. The three models available are a kitchen unit, a "Tourister" unit for portable use while traveling and a refrigerator unit that attaches to the ice cube water line. A filter will treat 5,000 to 10,000 gallons of water.

  15. Nanosilver as a disinfectant in dental unit waterlines: Assessment of the physiochemical transformations of the AgNPs

    EPA Science Inventory

    Dental unit water lines (DUWL) are susceptible to biofilm development and bacterial growth leading to water contamination, causing health and ecological effects. This study monitors the interactions between a commonly used nanosilver disinfectant (ASAP-AGX-32, an antimicrobial c...

  16. Growth and Identification of Bacteria in N-Halamine Dental Unit Waterline Tubing Using an Ultrapure Water Source

    PubMed Central

    Porteous, Nuala; Luo, Jie; Hererra, Monica; Schoolfield, John; Sun, Yuyu

    2011-01-01

    This study examined bacterial growth and type on biofilm-controlling dental unit waterline (DUWL) tubing (T) and control manufacturer's tubing (C) in a laboratory DUWL model using ultrapure source water that was cycled through the lines. Sections of tubing lines were detached and examined for biofilm growth using SEM imaging at six sampling periods. Bacteria from inside surfaces of T and C, source unit, and reservoir were cultured and enumerated. At six months, organisms were molecularly identified from the alignment matches obtained from the top three BLAST searches for the 16S region. There was a 1–3 log increase in organism growth in a clean, nonsterile reservoir within an hour. Biofilm was established on the inside surfaces of C within three weeks, but not on T. Proteobacteria, and Sphingomonas spp. were identified in the source reservoir and C line, and a variation of the genera was found in T line. PMID:22220171

  17. Effects of iodine in microbial control of dental treatment water.

    PubMed

    Puttaiah, Raghunath; Seibert, Jeff; Spears, Robert

    2011-05-01

    To determine the effects of low levels of iodine constantly present in the dental unit water system on microbial control of dental treatment water and biofilm control. This study used a dental unit water system simulator with eight dental unit waterline systems built to scale and function, each controlled via computer. Each of the eight units was operated independently, four units supplied with self-contained water reservoirs and four units supplied with municipal water. Four units were precleaned to remove biofilm buildup. The study had a well-balanced design with equal representation (variables) of presence/absence of biofilms, selfcontained reservoirs for introduction of treatment water, source water directly connected to municipal water source and iodinated cartridges within the self-contained reservoirs and between municipal water and dental unit. Point-of-use iodinated resin cartridges (IRC) were retrofitted proximal to handpiece and air/ water syringe tip lines in four units, and iodinated resin water cartridges (IRSWC) were fitted to the other four units at the source water output. Heterotrophic plate counts were performed at baseline and twice weekly for a period of 6 weeks. One representative waterline sample was taken from each group at baseline and end-of-study to analyze changes in biofilm status using scanning electron microscopy. Waterlines not previously contaminated with biofilms did not show organization of biofilm matrix in units equipped with IRSWC. Constantly present low levels of iodine, demonstrated some disruption of biofilms in waterlines already contaminated with mature biofilms. All groups showed contamination levels < 500 cfu/ml (colony forming units per milliliter) consistent with the CDC and ADA guidelines. In this 6 weeks study, IRSWC equipped waterlines showed disruption of established biofilms, controlled formation of new biofilms in clean lines and rendered the dental treatment water < 500 cfu/ml. Point-of-use iodinated resin cartridges were also effective in controlling contamination in the dental treatment water. Dental unit water systems that are in use get contaminated with microbes and biofilms in weeks of being put into use. These biofilms contaminate the treatment water thereby putting patients and staff at risk of infection by predominantly gram-negative microbes. Biofilms in the water systems must be cleaned periodically with a strong decontaminant and the dental treatment source water needs to be modified with a low-grade antimicrobial that can preserve the water quality yet safe to humans. In this translational research study, we evaluate the effects of elemental iodine dissolved in water flowing through an iodine containing cartridge in controlling biofilm and dental treatment water contamination using a dental unit water system simulator, prior to clinical utilization.

  18. Advances in on-line drinking water quality monitoring and early warning systems.

    PubMed

    Storey, Michael V; van der Gaag, Bram; Burns, Brendan P

    2011-01-01

    Significant advances have been made in recent years in technologies to monitor drinking water quality for source water protection, treatment operations, and distribution system management, in the event of accidental (or deliberate) contamination. Reports prepared through the Global Water Research Coalition (GWRC) and United States Environment Protection Agency (USEPA) agree that while many emerging technologies show promise, they are still some years from being deployed on a large scale. Further underpinning their viability is a need to interpret data in real time and implement a management strategy in response. This review presents the findings of an international study into the state of the art in this field. These results are based on visits to leading water utilities, research organisations and technology providers throughout Europe, the United States and Singapore involved in the development and deployment of on-line monitoring technology for the detection of contaminants in water. Copyright © 2010 Elsevier Ltd. All rights reserved.

  19. TRAC-BF1 thermal-hydraulic, ANSYS stress analysis for core shroud cracking phenomena

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shoop, U.; Feltus, M.A.; Baratta, A.J.

    1996-12-31

    The U.S. Nuclear Regulatory Commission sent Generic Letter 94-03 informing all licensees about the intergranular stress corrosion cracking (IGSCC) of core shrouds found in both Dresden unit I and Quad Cities unit 1. The letter directed all licensees to perform safety analysis of their boiling water reactor (BWR) units. Two transients of special concern for the core shroud safety analysis include the main steam line break (MSLB) and recirculation line break transient.

  20. Large Root Cortical Cell Size Improves Drought Tolerance in Maize1[C][W][OPEN

    PubMed Central

    Chimungu, Joseph G.; Brown, Kathleen M.

    2014-01-01

    The objective of this study was to test the hypothesis that large cortical cell size (CCS) would improve drought tolerance by reducing root metabolic costs. Maize (Zea mays) lines contrasting in root CCS measured as cross-sectional area were grown under well-watered and water-stressed conditions in greenhouse mesocosms and in the field in the United States and Malawi. CCS varied among genotypes, ranging from 101 to 533 µm2. In mesocosms, large CCS reduced respiration per unit of root length by 59%. Under water stress in mesocosms, lines with large CCS had between 21% and 27% deeper rooting (depth above which 95% of total root length is located in the soil profile), 50% greater stomatal conductance, 59% greater leaf CO2 assimilation, and between 34% and 44% greater shoot biomass than lines with small CCS. Under water stress in the field, lines with large CCS had between 32% and 41% deeper rooting (depth above which 95% of total root length is located in the soil profile), 32% lighter stem water isotopic ratio of 18O to 16O signature, signifying deeper water capture, between 22% and 30% greater leaf relative water content, between 51% and 100% greater shoot biomass at flowering, and between 99% and 145% greater yield than lines with small cells. Our results are consistent with the hypothesis that large CCS improves drought tolerance by reducing the metabolic cost of soil exploration, enabling deeper soil exploration, greater water acquisition, and improved growth and yield under water stress. These results, coupled with the substantial genetic variation for CCS in diverse maize germplasm, suggest that CCS merits attention as a potential breeding target to improve the drought tolerance of maize and possibly other cereal crops. PMID:25293960

  1. 2. GORGE HIGH DAM. UNUSUALLY HIGH WATER IN GORGE LAKE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. GORGE HIGH DAM. UNUSUALLY HIGH WATER IN GORGE LAKE DUE TO THE COMBINATION OF UNIT 24 BEING DOWN FOR REWINDING AND TWO UNITS COMING ON LINE UNEXPECTEDLY AT ROSS POWERHOUSE LED TO WATER FLOWING OVER THE SPILLGATES. EACH GATE IF 47 FEET WIDE AND 50 FEET HIGH, 1989. - Skagit Power Development, Gorge High Dam, On Skagit River, 2.9 miles upstream from Newhalem, Newhalem, Whatcom County, WA

  2. Efficacy of anti-retraction devices in preventing bacterial contamination of dental unit water lines.

    PubMed

    Berlutti, Francesca; Testarelli, Luca; Vaia, Francesco; De Luca, Massimo; Dolci, Giovanni

    2003-02-01

    In this study we examine the efficacy of anti-retraction devices in preventing microbial contamination of dental unit water lines (DUWLs). The study was performed on 54 randomly selected DUs in use at private and public institutions for over six months. The selected DUs were all currently commercially available. To evaluate the efficiency of anti-retraction devices, two different methods were employed, mechanical and microbiological. The ADA/ANSI specification #47 (corresponding to a water retraction of less than 40.3 microl) was used for the evaluation of the retraction determined using the mechanical method; the presence/absence of test microorganisms in DUWLs upstream the turbine after the test was used for evaluating the microbiological assay. Both evaluation methods indicated correct amounts of retraction and prevention of DUWL contamination occurred in only two cases (3.7%). Correct retraction was noted in six other dental units (DUs), but their DUWLs became contaminated during testing. Six other produced the opposite results-improper retraction, yet no contamination. The remaining 40 DUs (74.0%) failed both evaluations. The results showed that the overwhelming majority of the anti-retraction devices did not prevent retraction when the turbine stopped running, leading to a contamination of the water lines, and to a consequent possible cross-contamination of the patients.

  3. Economic comparison of conventional maintenance and electrochemical oxidation to warrant water safety in dental unit water lines

    PubMed Central

    Fischer, Sebastian; Meyer, Georg; Kramer, Axel

    2012-01-01

    Background: In preparation for implementation of a central water processing system at a dental department, we analyzed the costs of conventional decentralized disinfection of dental units against a central water treatment concept based on electrochemical disinfection. Methods: The cost evaluation included only the costs of annually required antimicrobial consumables and additional water usage of a decentralize conventional maintenance system for dental water lines build in the respective dental units and the central electrochemical water disinfection system, BLUE SAFETY™ Technologies. Results: In total, analysis of costs of 6 dental departments reviled additional annual costs for hygienic preventive measures of € 4,448.37. For the BLUE SAFETY™ Technology, the additional annual total agent consumption costs were € 2.18, accounting for approximately 0.05% of the annual total agent consumption costs of the conventional maintenance system. For both water processing concepts, the additional costs for energy could not be calculated, since the required data was not obtainable from the manufacturers. Discussion: For both concepts, the investment and maintenance costs were not calculated due to lack of manufacturer's data. Therefore, the results indicate the difference of costs for the required consumables only. Aside of the significantly lower annual costs for required consumables and disinfectants; a second advantage for the BLUE SAFETY™ Technology is its constant and automatic operation, which does not require additional staff resources. This not only safety human resources, but add additionally to cost saving. Conclusion: Since the antimicrobial disinfection capacity of the BLUE SAFETY™ was demonstrated previously and is well known, this technology, which is comparable or even superior in its non-corrosive effect, may be regarded as method of choice for continuous disinfection and prevention of biofilm formation in dental units’ water lines. PMID:22558042

  4. A System Approach to Navy Medical Education and Training. Appendix 24. Equipment Repair Technician.

    DTIC Science & Technology

    1974-08-31

    DENTAL SYRINGE 40 lCORRECT MALFUNCTIONING RETRACTION MECHANISM ON DENTAL UNIT 41 1ADJUST DRIP RATE ON AIR-DRIVEN DENTAL HANDPIECE 42 ICLEAN VALVE... DENTAL UNIT 46 CLEAN/REPLACE WATER FILTER ELEMENTS ON DENTAL UNIT 47 ICLEAR WATER LINES ON CONTRA-ANGLE AIR-DRIVEN DENTAL HANDPIECE 48 IREPLACE WORN...GASKETS ON AIR-DRIVEN DENTAL HANDPIECE 49 IADJUST END PLAY ON DENTAL HANOPIECE so ICLEAN AND REASSEMBLE BELT-DRIVEN DENTAL HANDPIECE TURN

  5. 33 CFR 168.40 - Applicable waters and number of escort vessels.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... a line drawn from Cape Hinchinbrook Light, to Seal Rocks Light, to a point on Montague Island at 60... waters and number of escort vessels. The requirements of this part apply to the following waters: (a... vessels in those navigable waters of the United States within Prince William Sound, Alaska, and the...

  6. Wavelength Locking to CO2 Absorption Line-Center for 2-Micron Pulsed IPDA Lidar Application

    NASA Technical Reports Server (NTRS)

    Refaat, Tamer F.; Petros, Mulugeta; Antill, Charles W.; Singh, Upendra N.; Yu, Jirong

    2016-01-01

    An airborne 2-micron triple-pulse integrated path differential absorption (IPDA) lidar is currently under development at NASA Langley Research Center (LaRC). This IPDA lidar system targets both atmospheric carbon dioxide (CO2) and water vapor (H2O) column measurements. Independent wavelength control of each of the transmitted laser pulses is a key feature for the success of this instrument. The wavelength control unit provides switching, tuning and locking for each pulse in reference to a 2-micron CW (Continuous Wave) laser source locked to CO2 line-center. Targeting the CO2 R30 line center, at 2050.967 nanometers, a wavelength locking unit has been integrated using semiconductor laser diode. The CO2 center-line locking unit includes a laser diode current driver, temperature controller, center-line locking controller and CO2 absorption cell. This paper presents the CO2 center-line locking unit architecture, characterization procedure and results. Assessment of wavelength jitter on the IPDA measurement error will also be addressed by comparison to the system design.

  7. Main steam-line break core shroud loading calculations for BWRs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shoop, U.; Feltus, M.A.; Baratta, A.J.

    1995-12-31

    In July 1994, the U.S. Nuclear regulatory Commission sent out Generic Letter 94-03 to all boiling water reactors in the United States, informing them of intergranular stress corrosion cracking of core shrouds found in 2 reactors. The letter directed all to perform safety analysis of the BWR units. Penn State performed scoping calculations to determine the forces experienced by the core shroud during a main-stream line break transient.

  8. Building America Case Study: Assessment of a Hybrid Retrofit Gas Water Heater

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    M. Hoeschele, E. Weitzel, C. Backman

    This project completed a modeling evaluation of a hybrid gas water heater that combines a reduced capacity tankless unit with a downsized storage tank. This product would meet a significant market need by providing a higher efficiency gas water heater solution for retrofit applications while maintaining compatibility with the half-inch gas lines and standard B vents found in most homes. The TRNSYS simulation tool was used to model a base case 0.60 EF atmospheric gas storage water, a 0.82 EF non-condensing gas tankless water heater, an existing (high capacity) hybrid unit on the market, and an alternative hybrid unit withmore » lower storage volume and reduced gas input requirements.« less

  9. An inflight refill unit for replenishing research animal drinking water

    NASA Technical Reports Server (NTRS)

    Savage, P. D.; Hines, M. L.; Barnes, R.

    1995-01-01

    This paper presents the design process and development approach for a method of maintaining sufficient quantities of water for research animals during a Shuttle mission of long duration. An inflight refill unit (IRU) consisting of two major subsystems, a fluid pumping unit (FPU) and a collapsible water reservoir (CWR), were developed. The FPU provides the system measurement and controls, pump, water lines, and plumbing necessary to collect water coming into the unit from the potable water system and pump it out into the RAHF drinking water tanks. The CWR is a Kevlar (TM) reinforced storage bladder connected to the FPU, which has a capacity of 6 liters in its expanded volume and functions to store the water collected from the potable water system, allowing for transport of the water back to the Spacelab where it is pumped into each of two research animal holding facilities. Additional components of the IRU system include the inlet and outlet fluid hoses, a power cable for providing 29V direct current spacecraft electrical power to the pump within the FPU, a tether system for the unit when in use in Spacelab, and an adapter for mating the unit to the orbiter waste collection system in order to dump excess water after use in Spacelab.

  10. 50 CFR 226.218 - Critical habitat for the U.S. DPS of smalltooth sawfish (Pristis pectinata).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... portions of Charlotte, Lee, Collier, Monroe, and Miami-Dade Counties. (1) Charlotte Harbor Estuary Unit. The Charlotte Harbor Estuary Unit is located within Charlotte and Lee Counties. The unit includes... Preserve, which is bounded on the south by the Lee/Collier County line. Inland waters are bounded by SR-867...

  11. 50 CFR 226.218 - Critical habitat for the U.S. DPS of smalltooth sawfish (Pristis pectinata).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... portions of Charlotte, Lee, Collier, Monroe, and Miami-Dade Counties. (1) Charlotte Harbor Estuary Unit. The Charlotte Harbor Estuary Unit is located within Charlotte and Lee Counties. The unit includes... Preserve, which is bounded on the south by the Lee/Collier County line. Inland waters are bounded by SR-867...

  12. Geothermal energy development in the Eastern United States. Technical assistance report no. 6, geothermal space heating and conditioning: McGuire Air Force Base, New Jersey

    NASA Astrophysics Data System (ADS)

    Hill, F. K.; Vonbriesen, R.

    1980-12-01

    The feasibility of space heating and cooling 200 multifamily on-base housing units using nonreversible heat pumps and ground water from 1000 ft. depth was studied. The 200 housing units are a part of the 1452 main base multifamily housing complex which is heated from a high temperature and pressure water line. The main system will be converted from natural gas to coal in 1984. Relative cost, amortization periods, and fossil fuel projections are compared.

  13. 76 FR 5567 - Energy Conservation Program for Consumer Products: Publication of the Petition for Waiver and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-01

    ... by blowing air through the wet clothes, condensing the water vapor in the airstream, and pumping the collected water into either a drain line or an in-unit container, these products do not use an exhaust port...

  14. COMBINED SEWER OVERFLOW - BALANCING FLOW FOR CSO ABATEMENT

    EPA Science Inventory

    Instead of using conventional storage units, e.g., reinforced concrete tanks and lined earthen basins, which are relatively expensive and require a lot of urban land area, the in-receiving water flow balance method (FBM) facilities use the receiving water body itself for storage ...

  15. Cost of Water Distribution System Infrastructure Rehabilitation, Repair, and Replacement.

    DTIC Science & Technology

    1985-03-01

    terms of the Hazen-Williams C-factor. New pipes have C-factors on the order of 140. Severely tuberculated pipes can have C-factors as low as 40. The C... tuberculation , and significantly higher pressures being required to push a pig through a small opening. Unit costs level off above the 10-in. diam and...additional costs of lining. Lining the pipe will: (a) prevent reoccurrence of tuberculation , (b) seal small leaks, and (c) eliminate "red - water" problems

  16. Remote water monitoring system

    NASA Technical Reports Server (NTRS)

    Grana, D. C.; Haynes, D. P. (Inventor)

    1978-01-01

    A remote water monitoring system is described that integrates the functions of sampling, sample preservation, sample analysis, data transmission and remote operation. The system employs a floating buoy carrying an antenna connected by lines to one or more sampling units containing several sample chambers. Receipt of a command signal actuates a solenoid to open an intake valve outward from the sampling unit and communicates the water sample to an identifiable sample chamber. Such response to each signal receipt is repeated until all sample chambers are filled in a sample unit. Each sample taken is analyzed by an electrochemical sensor for a specific property and the data obtained is transmitted to a remote sending and receiving station. Thereafter, the samples remain isolated in the sample chambers until the sampling unit is recovered and the samples removed for further laboratory analysis.

  17. Increased water contamination and grow-out Pekin duck mortality when raised with water troughs compared to pin-metered water lines using a United States management system

    PubMed Central

    Schenk, A.; Porter, A. L.; Alenciks, E.; Frazier, K.; Best, A. A.; Fraley, S. M.; Fraley, G. S.

    2016-01-01

    Controversy has developed as to whether or not pin-metered water lines or water troughs are more appropriate for Pekin ducks. We hypothesized that water troughs would show improved duck body conditions and environmental quality compared to pin-metered water lines. To test this hypothesis, we housed ducks in 2 barns, one with water lines and one with water troughs. Water troughs were constructed to meet RSPCA guidelines for number and density of ducks and with recently described verandas. Ducks were divided into 4 pens per barn (n = 1,000 ducks/pen). The study was then repeated (n = 8 pens per water source) in a cross-over design so the barns each contained the opposite water source to the first experiment. We scored the ducks’ body condition using an established scoring rubric and analyzed using SAS Proc GLM-Mix as binomial data. Ducks housed with water troughs showed higher (thus worse condition; P < 0.001) scores for eyes, nostrils, feather quality, feather cleanliness, and foot pads. We also compared water condition, water quality, and duck mortality using a Student t test for both water sources each week. We found that the water troughs showed higher iron (P < 0.001), nitrites (P < 0.001), pH (P < 0.01), and bacterial growth (P < 0.001). The bacterial growth was shown to have higher (P < 0.001) E. coli, coliforms, and Staphylococcus in the water troughs. Water lines typically showed no bacterial growth in culture-based assays. Ducks housed with water troughs used greater (P = 0.001) volumes of water compared to ducks housed with water lines. Ducks with water troughs also showed a greater percent (P = 0.008) mortality at all ages compared to ducks with water lines. These data suggest that water troughs may not be beneficial for duck welfare and could adversely impact both environment and duck or human health. PMID:26769272

  18. Increased water contamination and grow-out Pekin duck mortality when raised with water troughs compared to pin-metered water lines using a United States management system.

    PubMed

    Schenk, A; Porter, A L; Alenciks, E; Frazier, K; Best, A A; Fraley, S M; Fraley, G S

    2016-04-01

    Controversy has developed as to whether or not pin-metered water lines or water troughs are more appropriate for Pekin ducks. We hypothesized that water troughs would show improved duck body conditions and environmental quality compared to pin-metered water lines. To test this hypothesis, we housed ducks in 2 barns, one with water lines and one with water troughs. Water troughs were constructed to meet RSPCA guidelines for number and density of ducks and with recently described verandas. Ducks were divided into 4 pens per barn (n=1,000 ducks/pen). The study was then repeated (n=8 pens per water source) in a cross-over design so the barns each contained the opposite water source to the first experiment. We scored the ducks' body condition using an established scoring rubric and analyzed using SAS Proc GLM-Mix as binomial data. Ducks housed with water troughs showed higher (thus worse condition; P<0.001) scores for eyes, nostrils, feather quality, feather cleanliness, and foot pads. We also compared water condition, water quality, and duck mortality using a Student t test for both water sources each week. We found that the water troughs showed higher iron (P<0.001), nitrites (P<0.001), pH (P<0.01), and bacterial growth (P<0.001). The bacterial growth was shown to have higher (P<0.001)E. coli, coliforms, and Staphylococcusin the water troughs. Water lines typically showed no bacterial growth in culture-based assays. Ducks housed with water troughs used greater (P=0.001) volumes of water compared to ducks housed with water lines. Ducks with water troughs also showed a greater percent (P=0.008) mortality at all ages compared to ducks with water lines. These data suggest that water troughs may not be beneficial for duck welfare and could adversely impact both environment and duck or human health. © The Author 2016. Published by Oxford University Press on behalf of Poultry Science Association.

  19. Meteoric sphaerosiderite lines and their use for paleohydrology and paleoclimatology

    USGS Publications Warehouse

    Ludvigson, Greg A.; Gonzalez, Luis A.; Metzger, R.A.; Witzke, B.J.; Brenner, Richard L.; Murillo, A.P.; White, T.S.

    1998-01-01

    Sphaerosiderite, a morphologically distinct millimeter-scale spherulitic siderite (FeCO3), forms predominantly in wetland soils and sediments, and is common in the geologic record. Ancient sphaerosiderites are found in paleosol horizons within coal-bearing stratigraphic intervals and, like their modern counterparts, are interpreted as having formed in water-saturated environments. Here we report on sphaerosiderites from four different stratigraphic units, each of which has highly variable 13C and relatively stable 18O compositions. The unique isotopic trends are analogous to well-documented meteoric calcite lines, which we define here as meteoric sphaerosiderite lines. Meteoric sphaerosiderite lines provide a new means of constraining ground-water ??18O and thus allow evaluation of paleohydrology and paleoclimate in humid continental settings.

  20. Ozone processing of foods and beverages

    USDA-ARS?s Scientific Manuscript database

    Ozone has a long history of use as a disinfectant in food and beverage processing. In the United States, the application of ozone to disinfect bottled water was approved as Generally Recognized As Safe (GRAS) in 1982. Later it was approved as a sanitizing agent for bottled water treatment lines. Ozo...

  1. New on-line method for water isotope analysis of speleothem fluid inclusions using laser absorption spectroscopy (WS-CRDS)

    NASA Astrophysics Data System (ADS)

    Affolter, S.; Fleitmann, D.; Leuenberger, M.

    2014-01-01

    A new online method to analyse water isotopes of speleothem fluid inclusions using a wavelength scanned cavity ring down spectroscopy (WS-CRDS) instrument is presented. This novel technique allows us to simultaneously measure hydrogen and oxygen isotopes for a released aliquot of water. To do so, we designed a new simple line that allows the on-line water extraction and isotope analysis of speleothem samples. The specificity of the method lies in the fact that fluid inclusions release is made on a standard water background, which mainly improves the δD reliability. To saturate the line, a peristaltic pump continuously injects standard water into the line that is permanently heated to 140 °C and flushed with dry nitrogen gas. This permits instantaneous and complete vaporisation of the standard water resulting in an artificial water background with well-known δD and δ18O values. The speleothem sample is placed into a copper tube, attached to the line and after system stabilisation is crushed using a simple hydraulic device to liberate speleothem fluid inclusions water. The released water is carried by the nitrogen/standard water gas stream directly to a Picarro L1102-i for isotope determination. To test the accuracy and reproducibility of the line and to measure standard water during speleothem measurements a syringe injection unit was added to the line. Peak evaluation is done similarly as in gas chromatography to obtain δD and δ18O isotopic composition of measured water aliquots. Precision is better than 1.5‰ for δD and 0.4‰ for δ18O for water measurement for an extended range (-210 to 0‰ for δD and -27 to 0‰ for δ18O) primarily dependent on the amount of water released from speleothem fluid inclusions and secondarily on the isotopic composition of the sample. The results show that WS-CRDS technology is suitable for speleothem fluid inclusion measurements and gives results that are comparable to Isotope Ratio Mass Spectrometry (IRMS) technique.

  2. Reduced Lateral Root Branching Density Improves Drought Tolerance in Maize1[OPEN

    PubMed Central

    Zhan, Ai; Schneider, Hannah

    2015-01-01

    An emerging paradigm is that root traits that reduce the metabolic costs of soil exploration improve the acquisition of limiting soil resources. Here, we test the hypothesis that reduced lateral root branching density will improve drought tolerance in maize (Zea mays) by reducing the metabolic costs of soil exploration, permitting greater axial root elongation, greater rooting depth, and thereby greater water acquisition from drying soil. Maize recombinant inbred lines with contrasting lateral root number and length (few but long [FL] and many but short [MS]) were grown under water stress in greenhouse mesocosms, in field rainout shelters, and in a second field environment with natural drought. Under water stress in mesocosms, lines with the FL phenotype had substantially less lateral root respiration per unit of axial root length, deeper rooting, greater leaf relative water content, greater stomatal conductance, and 50% greater shoot biomass than lines with the MS phenotype. Under water stress in the two field sites, lines with the FL phenotype had deeper rooting, much lighter stem water isotopic signature, signifying deeper water capture, 51% to 67% greater shoot biomass at flowering, and 144% greater yield than lines with the MS phenotype. These results entirely support the hypothesis that reduced lateral root branching density improves drought tolerance. The FL lateral root phenotype merits consideration as a selection target to improve the drought tolerance of maize and possibly other cereal crops. PMID:26077764

  3. Evaluation of the Antimicrobial Functions of N-halamine Dental Unit Waterline Tubing for One Year.

    PubMed

    Porteous, N; Dang, S; Schoolfield, J; Sun, Y

    2016-03-01

    The objective of this study was to test the biofilm-controlling properties of N-halamine antimicrobial dental unit waterline (DUWL) tubing (T) tubing, without recharging over one year, compared to a control line (C). A simulated clinical model was used to pump ultrapure water through T and C lines at a rate of 1.4 mL/min, five minutes on, 15 minutes off, eight hours/day, five days a week. Samples of source water, effluent from T and C, and from the stagnant water in the carboy (liquid container) after bench work was completed (S2), were collected aseptically, serially diluted, and cultured on R2A agar for seven days every six weeks. SEM images of the inside surfaces of detached tubing sections were also taken. The carboy was rinsed with a 1:10 dilution of sodium hypochlorite after six months. Means of log transformed CFU values obtained in triplicate were paired by T and C lines across months for comparison by paired Student's t-tests. An increase in effluent and carboy bacterial counts were noted after six months, but decreased after bleach rinse of the carboy. No significant difference (p > 0.25) between T and C lines were observed; similarly, T and carboy were not significantly different (p > 0.30). SEM images showed biofilm attachment on the inside surface of C after two months, but not on T. Organisms identified in the effluent reflected those in the source carboy. No biofilm attachment was detected on the N-halamine test line after 12 months, indicating its antimicrobial properties were retained. Further evaluation is recommended to determine the optimal recharge interval for N-halamine DUWL tubing when ultrapure source water is used.

  4. Evaluation of the Antimicrobial Functions of N-halamine Dental Unit Waterline Tubing for One Year

    PubMed Central

    Porteous, N.; Dang, S.; Schoolfield, J.; Sun, Y.

    2017-01-01

    Objective The objective of this study was to test the biofilm-controlling properties of N-halamine antimicrobial dental unit waterline (DUWL) tubing (T) tubing, without recharging over one year, compared to a control line (C). Methods A simulated clinical model was used to pump ultrapure water through T and C lines at a rate of 1.4 mL/min, five minutes on, 15 minutes off, eight hours/day, five days a week. Samples of source water, effluent from T and C, and from the stagnant water in the carboy (liquid container) after bench work was completed (S2), were collected aseptically, serially diluted, and cultured on R2A agar for seven days every six weeks. SEM images of the inside surfaces of detached tubing sections were also taken. The carboy was rinsed with a 1:10 dilution of sodium hypochlorite after six months. Means of log transformed CFU values obtained in triplicate were paired by T and C lines across months for comparison by paired Student’s t-tests. Results An increase in effluent and carboy bacterial counts were noted after six months, but decreased after bleach rinse of the carboy. No significant difference (p > 0.25) between T and C lines were observed; similarly, T and carboy were not significantly different (p > 0.30). SEM images showed biofilm attachment on the inside surface of C after two months, but not on T. Organisms identified in the effluent reflected those in the source carboy. Conclusions No biofilm attachment was detected on the N-halamine test line after 12 months, indicating its antimicrobial properties were retained. Further evaluation is recommended to determine the optimal recharge interval for N-halamine DUWL tubing when ultrapure source water is used. PMID:28390212

  5. Memory Metals

    NASA Technical Reports Server (NTRS)

    1995-01-01

    Under contract to NASA during preparations for the space station, Memry Technologies Inc. investigated shape memory effect (SME). SME is a characteristic of certain metal alloys that can change shape in response to temperature variations. In the late 1980s and early 1990s, Memry used its NASA-acquired expertise to produce a line of home and industrial safety products, and refined the technology in the mid-1990s. Among the new products they developed are three MemrySafe units which prevent scalding from faucets. Each system contains a small valve that reacts to temperature, not pressure. When the water reaches dangerous temperatures, the unit reduces the flow to a trickle; when the scalding temperature subsides, the unit restores normal flow. Other products are the FIRECHEK 2 and 4, heat-activated shutoff valves for industrial process lines, which sense excessive heat and cut off pneumatic pressure. The newest of these products is Memry's Demand Management Water Heater which shifts the electricity requirement from peak to off-peak demands, conserving energy and money.

  6. Does It Mix?

    ERIC Educational Resources Information Center

    Kennon, J. Tillman; Fong, Bryant; Grippo, Anne

    2016-01-01

    This article describes how by using three points to make a line and comparing the graphs for water and oil, students can mathematically demonstrate that Gatorade dissolves in water much more readily than in oil. Students can also use units to understand and solve a multi-step problem by observing the color of each solution, making conductivity…

  7. The ISO Long Wavelength Spectrometer line spectrum of VY Canis Majoris and other oxygen-rich evolved stars

    NASA Astrophysics Data System (ADS)

    Polehampton, E. T.; Menten, K. M.; van der Tak, F. F. S.; White, G. J.

    2010-02-01

    Context. The far-infrared spectra of circumstellar envelopes around various oxygen-rich stars were observed using the ISO Long Wavelength Spectrometer (LWS). These have been shown to be spectrally rich, particularly in water lines, indicating a high H2O abundance. Aims: We have examined high signal-to-noise ISO LWS observations of the luminous supergiant star, VY CMa, with the aim of identifying all of the spectral lines. By paying particular attention to water lines, we aim to separate the lines due to other species, in particular, to prepare for forthcoming observations that will cover the same spectral range using Herschel PACS and at higher spectral resolution using Herschel HIFI and SOFIA. Methods: We have developed a fitting method to account for blended water lines using a simple weighting scheme to distribute the flux. We have used this fit to separate lines due to other species which cannot be assigned to water. We have applied this approach to several other stars which we compare with VY CMa. Results: We present line fluxes for the unblended H2O and CO lines, and present detections of several possible ν2=1 vibrationally excited water lines. We also identify blended lines of OH, one unblended and several blended lines of NH3, and one possible detection of H3O+. Conclusions: The spectrum of VY CMa shows a detection of emission from virtually every water line up to 2000 K above the ground state, as well as many additional higher energy and some vibrationally excited lines. A simple rotation diagram analysis shows large scatter (probably due to some optically thick lines). The fit gives a rotational temperature of 670+210-130 K, and lower limit on the water column density of (7.0±1.2) × 1019 cm-2. We estimate a CO column density ~100 times lower, showing that water is the dominant oxygen carrier. The other stars that we examined have similar rotation temperatures, but their H2O column densities are an order of magnitude lower (as are the mass loss rates). Based on observations with ISO, an ESA project with instruments funded by ESA Member States (especially the PI countries: France, Germany, the Netherlands and the United Kingdom) with the participation of ISAS and NASA.Current address: Space Science Department, Rutherford Appleton Laboratory, UK

  8. Segmentation of Environmental Time Lapse Image Sequences for the Determination of Shore Lines Captured by Hand-Held Smartphone Cameras

    NASA Astrophysics Data System (ADS)

    Kröhnert, M.; Meichsner, R.

    2017-09-01

    The relevance of globally environmental issues gains importance since the last years with still rising trends. Especially disastrous floods may cause in serious damage within very short times. Although conventional gauging stations provide reliable information about prevailing water levels, they are highly cost-intensive and thus just sparsely installed. Smartphones with inbuilt cameras, powerful processing units and low-cost positioning systems seem to be very suitable wide-spread measurement devices that could be used for geo-crowdsourcing purposes. Thus, we aim for the development of a versatile mobile water level measurement system to establish a densified hydrological network of water levels with high spatial and temporal resolution. This paper addresses a key issue of the entire system: the detection of running water shore lines in smartphone images. Flowing water never appears equally in close-range images even if the extrinsics remain unchanged. Its non-rigid behavior impedes the use of good practices for image segmentation as a prerequisite for water line detection. Consequently, we use a hand-held time lapse image sequence instead of a single image that provides the time component to determine a spatio-temporal texture image. Using a region growing concept, the texture is analyzed for immutable shore and dynamic water areas. Finally, the prevalent shore line is examined by the resultant shapes. For method validation, various study areas are observed from several distances covering urban and rural flowing waters with different characteristics. Future work provides a transformation of the water line into object space by image-to-geometry intersection.

  9. 78 FR 20133 - Notice of Intent To Prepare an Environmental Impact Statement for the Proposed Bull Mountain Unit...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-03

    ... associated pads, access roads, gas and water pipelines, screw compressors and overhead electric lines. This... projected air quality impacts. The project was initially scoped from October 29 to December 12, 2008, for 55..., the BLM has identified the following preliminary issues: Air quality; water quality and supply...

  10. 40 CFR 52.2070 - Identification of plan.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... steam or hot water generating units 10/5/1982 3/29/1983, 48 FR 13026 Air Pollution Control Regulation 14... emissions from six paper coating lines. (A) Letter from the RIDEM dated November 5, 1985 submitting...

  11. Uncertainties of the Intensity of the 1130 nm Band of Water Vapor

    NASA Technical Reports Server (NTRS)

    Giver, L. P.; Pilewskie, P.; Gore, W. J.; Chackerian, C., Jr.; Varanasi, P.; Bergstrom, R.; Freedman, R. S.

    2001-01-01

    Belmiloud, et al have recently suggested that the HITRAN line intensities in the 1130 nm water vapor band are much too weak. Giver, et at corrected unit conversion errors to make the HITRAN intensities compatible with the original measurements of Mandin, et al, but Belmiloud, et al believe that many of those line intensity measurements were too weak, and they propose the total intensity of the 1130 nm water vapor band is 38% stronger than the sum of the HITRAN line intensities in this region. We have made independent assessments of this proposal using 2 spectra obtained with the Ames 25 meter base path White cell. The first was made using the moderate resolution (8 nm) solar spectral flux radiometer (SSFR) flight instrument with a White cell absorbing path of 506 meters and 10 torr water vapor pressure. Modeling this spectrum using the HITRAN linelist gives a reasonable match, and the model is not compatible when the HITRAN line intensities are increased by 38%. The second spectrum was obtained with a White cell path of 1106 meters and 12 torr water vapor pressure, using a Bomem FTIR with near Doppler width resolution. This spectrum is useful for measuring intensities of isolated weak lines to compare with the measurements of Mandin, et al. Unfortunately, as Belmiloud et al point out, at these conditions the strong lines are much too saturated for good intensity measurements. Our measurements of the weak lines are in reasonable agreement with those of Mandin, et al. Neither of our spectra supports the proposal of Belmiloud et al for a general 38% increase of the absorption intensity in the 1130 nm water vapor band.

  12. An audit improves the quality of water within the dental unit water lines of three separate facilities of a United Kingdom NHS Trust.

    PubMed

    Chate, R A C

    2006-11-11

    To improve the quality of water emanating from dental unit waterlines (DUWLs). A prospective clinical audit. Three geographically separate district dental facilities of a United Kingdom NHS Trust, involving two community clinics and one hospital orthodontic department, which were evaluated between 2002 and 2004. Samples of water discharged from the DUWLs were collected prior to the start and midway through a morning session. These were tested microbiologically at a United Kingdom Accreditation Service testing laboratory within six hours of sampling. One of the clinics followed the contemporaneous BDA advice of flushing water through its DUWLs while the other two clinics used separate intermittent disinfection purging regimes instead. One of them used a two stage protocol of Ethylene Diamine Tetra-Acetic acid followed by hydrogen peroxide, while the other used Bio 2000 as a single agent, which was subsequently superseded by the continuous use of super-oxidised water (Sterilox). To assess whether the samples either met the American Dental Association's guideline on the quality of DUWL water, or the more stringent European Union standards for potable (drinking) water. The two units which used a disinfection regime both complied with the ADA guideline and the EU potable water standard. However, the unit which only flushed through its DUWLs without using a disinfectant failed to comply with either of them. After all three dental facilities subsequently standardised their DUWL disinfection regimes by using Bio 2000, the colony counts from all of the water samples thereafter remained well below the EU recommended level. The unit which progressed to using Sterilox as a continuous disinfectant achieved and maintained zero readings from its water samples. Clinical audit can result in the improvement of the quality of water that is discharged through DUWLs, thereby minimising both the risk of cross infection to vulnerable patients, as well as to dental staff chronically exposed to contaminated aerosols.

  13. 40 CFR 52.2070 - Identification of plan.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... fuel fired steam or hot water generating units 10/5/1982 3/29/1983, 48 FR 13026 Air Pollution Control... organic solvent emissions from six paper coating lines. (A) Letter from the RIDEM dated November 5, 1985...

  14. Evaluation of the PotoClean® decontamination technology for reprocessing of water supply lines in dental units during routine work

    PubMed Central

    Kramer, Axel; Koburger, Torsten; Taube, Lisa-Dorothea; Menzel, Michael; Meyer, Georg; Assadian, Ojan

    2012-01-01

    Background: A frequent problem in dental units is the microbial contamination of water and biofilm formation in the water supply lines. After random identification of a bacterial contaminated dental unit (310 cfu/ml) in a practise with 3 dental units we implemented the present study to evaluate the efficacy of the PotoClean® technology, based on anodic oxidation. Method: The efficacy of a regular low concentrated permanent decontamination (1 mg Cl/L) with an additional intensive decontamination by PotoClean® (three times 20 mg Cl/ml for 2 h) on three dental units was tested over 7 months. Microbial contamination, total chlorine concentration and redox potential have been analyzed. Dental unit A and B was 15 years old, unit C 5 years. Results: After 3 intensive decontaminations, in dental unit A and B the number of bacteria and moulds could be reduced less than 7 d. Thereafter the bacteria counts increased again during the subsequent 7 month period and the amount of moulds was with some exceptions 300 cfu/ml, although PotoClean® was constantly added in the system (1 mg Cl/L). After further 7.5 month only with low concentrated permanent disinfection (1 mg Cl/L) both units were successful decontaminated. Dental unit C represented an object which was easier to decontaminate because of the advanced construction (prevention of water stagnation) and the shorter useful life. At the beginning of the decontamination it was no bacterial contamination, but moulds were contained (300 cfu/ml). Already after the first intensive decontamination, no further bacteria and moulds could be detected. Discussion: An important factor for the efficacy of PotoClean® was the age of the units and their construction. For a new generation of dental units PotoClean® was effective during the whole period of monitoring. For two old types of dental unit with massive biofilm development the successful decontamination needed more than 7 month. Conclusion: The PotoClean® technology has resulted in even old-type turbines with intensive biofilm formation to complete decontamination. In a recent turbine design already after the first intensive decontamination with PotoClean® and its continuous use (1 mg Cl/L) no more contamination by bacteria and moulds were detectable. PMID:22558044

  15. Evaluation of the PotoClean(®) decontamination technology for reprocessing of water supply lines in dental units during routine work.

    PubMed

    Kramer, Axel; Koburger, Torsten; Taube, Lisa-Dorothea; Menzel, Michael; Meyer, Georg; Assadian, Ojan

    2012-01-01

    A frequent problem in dental units is the microbial contamination of water and biofilm formation in the water supply lines. After random identification of a bacterial contaminated dental unit (310 cfu/ml) in a practise with 3 dental units we implemented the present study to evaluate the efficacy of the PotoClean(®) technology, based on anodic oxidation. The efficacy of a regular low concentrated permanent decontamination (1 mg Cl/L) with an additional intensive decontamination by PotoClean(®) (three times 20 mg Cl/ml for 2 h) on three dental units was tested over 7 months. Microbial contamination, total chlorine concentration and redox potential have been analyzed. Dental unit A and B was 15 years old, unit C 5 years. After 3 intensive decontaminations, in dental unit A and B the number of bacteria and moulds could be reduced less than 7 d. Thereafter the bacteria counts increased again during the subsequent 7 month period and the amount of moulds was with some exceptions 300 cfu/ml, although PotoClean(®) was constantly added in the system (1 mg Cl/L). After further 7.5 month only with low concentrated permanent disinfection (1 mg Cl/L) both units were successful decontaminated. Dental unit C represented an object which was easier to decontaminate because of the advanced construction (prevention of water stagnation) and the shorter useful life. At the beginning of the decontamination it was no bacterial contamination, but moulds were contained (300 cfu/ml). Already after the first intensive decontamination, no further bacteria and moulds could be detected. An important factor for the efficacy of PotoClean(®) was the age of the units and their construction. For a new generation of dental units PotoClean(®) was effective during the whole period of monitoring. For two old types of dental unit with massive biofilm development the successful decontamination needed more than 7 month. The PotoClean(®) technology has resulted in even old-type turbines with intensive biofilm formation to complete decontamination. In a recent turbine design already after the first intensive decontamination with PotoClean(®) and its continuous use (1 mg Cl/L) no more contamination by bacteria and moulds were detectable.

  16. New online method for water isotope analysis of speleothem fluid inclusions using laser absorption spectroscopy (WS-CRDS)

    NASA Astrophysics Data System (ADS)

    Affolter, S.; Fleitmann, D.; Leuenberger, M.

    2014-07-01

    A new online method to analyse water isotopes of speleothem fluid inclusions using a wavelength scanned cavity ring down spectroscopy (WS-CRDS) instrument is presented. This novel technique allows us simultaneously to measure hydrogen and oxygen isotopes for a released aliquot of water. To do so, we designed a new simple line that allows the online water extraction and isotope analysis of speleothem samples. The specificity of the method lies in the fact that fluid inclusions release is made on a standard water background, which mainly improves the δ D robustness. To saturate the line, a peristaltic pump continuously injects standard water into the line that is permanently heated to 140 °C and flushed with dry nitrogen gas. This permits instantaneous and complete vaporisation of the standard water, resulting in an artificial water background with well-known δ D and δ18O values. The speleothem sample is placed in a copper tube, attached to the line, and after system stabilisation it is crushed using a simple hydraulic device to liberate speleothem fluid inclusions water. The released water is carried by the nitrogen/standard water gas stream directly to a Picarro L1102-i for isotope determination. To test the accuracy and reproducibility of the line and to measure standard water during speleothem measurements, a syringe injection unit was added to the line. Peak evaluation is done similarly as in gas chromatography to obtain &delta D; and δ18O isotopic compositions of measured water aliquots. Precision is better than 1.5 ‰ for δ D and 0.4 ‰ for δ18O for water measurements for an extended range (-210 to 0 ‰ for δ D and -27 to 0 ‰ for δ18O) primarily dependent on the amount of water released from speleothem fluid inclusions and secondarily on the isotopic composition of the sample. The results show that WS-CRDS technology is suitable for speleothem fluid inclusion measurements and gives results that are comparable to the isotope ratio mass spectrometry (IRMS) technique.

  17. Development of an In-Flight Refill Unit for Replenishing Research Animal Drinking Water

    NASA Technical Reports Server (NTRS)

    Savage, P. D.; Hines, M. I.; Barnes, R.

    1994-01-01

    The Spacelab Life Sciences 2 (SLS-2) mission became NASA's longest duration Shuttle mission, lasting fourteen days, when Columbia landed on 1 Nov. 1993. Located within the Spacelab were a total of 48 laboratory rats which were housed in two Research Animal Holding Facilities (RAHF's) developed by the Space Life Sciences Payloads Office (SLSPO) at Ames Research Center. In order to properly maintain the health and well-being of these important research animals, sufficient quantities of food and water had to be available for the duration of the mission. An inflight Refill Unit was developed by the SLSPO to replenish the animals' drinking water inflight using the Shuttle potable water system in the middeck galley as the source of additional water. The Inflight Refill Unit consists of two major subsystems, a Fluid Pumping Unit (FPU) and a Collapsible Water Reservoir (CWR). The FPU provides the system measurement and controls, pump, water lines, and plumbing necessary to collect water coming into the unit from the potable water system and pump it out and into the RAHF drinking water tanks. The CWR is a Kevlar(trademark) reinforced storage bladder, connected to the FPU, which has a capacity of 6 liters in its expanded volume and functions to store the water collected from the potable water system and allows for the transport of the water back to the Spacelab where it is pumped into each of two RAHFs. Additional components of the FPU system include the inlet and outlet fluid hoses, a power cable for providing 28 volt direct current spacecraft electrical power to the pump within the FPU, a tether system for the unit when in use in Spacelab, and an adapter for mating the unit to the orbiter waste collection system in order to dump excess water after use in Spacelab. This paper will present the design process and development approach for the lnflight Refill Unit, define some of the key design issues which had to be addressed, and summarize the inflight operational performance of the unit during the SLS-2 mission.

  18. REPHLEX II: An information management system for the ARS Water Data Base

    NASA Astrophysics Data System (ADS)

    Thurman, Jane L.

    1993-08-01

    The REPHLEX II computer system is an on-line information management system which allows scientists, engineers, and other researchers to retrieve data from the ARS Water Data Base using asynchronous communications. The system features two phone lines handling baud rates from 300 to 2400, customized menus to facilitate browsing, help screens, direct access to information and data files, electronic mail processing, file transfers using the XMODEM protocol, and log-in procedures which capture information on new users, process passwords, and log activity for a permanent audit trail. The primary data base on the REPHLEX II system is the ARS Water Data Base which consists of rainfall and runoff data from experimental agricultural watersheds located in the United States.

  19. Procurement Opportunitites in: Afghanistan and the Central Asian States (CAS)

    DTIC Science & Technology

    2012-08-01

    barriers) Furniture (office and household) Prefabricated Structures (CONEXs, containerized housing units, re-locatable buildings) Office Supplies... Concrete Foundation and Structure Road Support Activities Minor Building Renovation Water and Sewer Line and Related Construction Heavy and Civil

  20. Evaluation of microbial profile in dental unit waterlines and assessment of antimicrobial efficacy of two treating agents.

    PubMed

    Mungara, J; Dilna, N C; Joseph, E; Reddy, N

    2013-01-01

    The quality of water in a dental unit used for cooling and flushing the high and low speed handpiece, air/water syringes and the scalers is of considerable importance. The present study was carried out to enumerate and identify the microorganisms present in water samples collected from dental unit waterlines of different dental specialty clinics and to find out the efficacy of two treating agents in disinfecting dental unit waterlines. Sample included 70 dental unit waterlines from different speciality dental clinics which were checked for microbial contamination. From these dental units 40 units were randomly selected and divided into two groups of 20 each. Group A, treatment was done in 20 dental units with 0.2% Chlorhexidine gluconate solution and Group B, treatment was done in 20 dental units with 10% Povidone iodine solution and the reduction in the microbial levels were assessed. Five dental units were randomly selected and checked the microbial contamination using mineral water sterile distilled water fresh tap water as a water source in the dental unit reservoir bottles. Also from the test group, five from each group were checked for the duration of efficacy of treating agent for one week by analyzing the water samples collected on 3,5 and 7 day intervals. Most of the identified microorganisms are Gram negative and pseudomonas predominating up to 98.59% of the total isolates. Usage of disinfectants 0.2% Chlorhexidine and 10% Povidone Iodine were found to be very effective in reducing the microbial contamination and 10% Povidone iodine was found to be more efficient (97.13%) and active for a period of 3 days and gradually loosing its efficacy by 7th day. No significant difference were found in microbial contamination of water samples collected from different water outlets such as handpiece outlets, air water syringe outlets, scaler lines. To continue maintaining the sterility of the Dental unit waterlines and to complete the infection control measures adopted in the dental clinics, suitable disinfectants like 0.2% Chlorhexidine on daily basis or 10% Povidone iodine on every 3rd day basis intermittently maintain the sterility of dental unit waterlines it is essential to have a good water source and an effective disinfectant.

  1. Detection of carbon monoxide and water absorption lines in an exoplanet atmosphere.

    PubMed

    Konopacky, Quinn M; Barman, Travis S; Macintosh, Bruce A; Marois, Christian

    2013-03-22

    Determining the atmospheric structure and chemical composition of an exoplanet remains a formidable goal. Fortunately, advancements in the study of exoplanets and their atmospheres have come in the form of direct imaging--spatially resolving the planet from its parent star--which enables high-resolution spectroscopy of self-luminous planets in jovian-like orbits. Here, we present a spectrum with numerous, well-resolved molecular lines from both water and carbon monoxide from a massive planet orbiting less than 40 astronomical units from the star HR 8799. These data reveal the planet's chemical composition, atmospheric structure, and surface gravity, confirming that it is indeed a young planet. The spectral lines suggest an atmospheric carbon-to-oxygen ratio that is greater than that of the host star, providing hints about the planet's formation.

  2. Effects of Hydrogen Peroxide on Dental Unit Biofilms and Treatment Water Contamination

    PubMed Central

    Lin, Shih-Ming; Svoboda, Kathy K.H.; Giletto, Anthony; Seibert, Jeff; Puttaiah, Raghunath

    2011-01-01

    Objectives: To study effects of various concentrations of hydrogen peroxide on mature waterline biofilms and in controlling planktonic (free-floating) organisms in simulated dental treatment water systems; and to study in vitro the effects of 2%, 3%, and 7% hydrogen peroxide on the removal of mature biofilms and inorganic compounds in dental waterlines. Methods: Four units of an automated dental unit water system simulation device was used for 12 weeks. All units were initially cleaned to control biofilms and inorganic deposits. H2O2 at concentrations of 1%, 2%, 3% was used weekly for periodic cleaning in three treatment group units (units 1, 2 & 3), with 0.05%, 0.15% and 0.25% H2O2 in municipal water used as irrigant respectively. The control unit (unit 4) did not have weekly cleanings and used municipal water as irrigant. Laser Scanning Confocal Microscopy and Scanning Electron Microscopy were used to study deposits on lines, and weekly heterotrophic plate counts done to study effluent water contamination. A 24 hour in vitro challenge test with 7%, 3% and 2% H2O2 on mature biofilms was conducted using harvested waterlines to study biofilm and inorganic deposit removal. Results: Heterotrophic plate counts of effluent water showed that the control unit reached contamination levels in excess of 400,000 CFU/mL while all treatment units showed contamination levels <500 CFU/mL through most of the 12 weeks. All treatment units showed varying levels of biofilm and inorganic deposit control in this short 12 week study. The in vitro challenge test showed although there was biofilm control, there was no eradication even when 7% H2O2 was used for 24 hours. Conclusions: 2% H2O2 used as a periodic cleaner, and diluted to 0.05% in municipal water for irrigation was beneficial in controlling biofilm and planktonic contamination in dental unit water systems. However, to remove well established biofilms, it may take more than 2 months when initial and multiple periodic cleanings are performed using H2O2. PMID:21228956

  3. 46 CFR 401.300 - Authorization for establishment of pools.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... longitude 84°33′ W. at the northern approach. (b) The Director shall determine the number of pools that will... United States waters of the St. Lawrence River between the international boundary at St. Regis and a line...

  4. 46 CFR 401.300 - Authorization for establishment of pools.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... longitude 84°33′ W. at the northern approach. (b) The Director shall determine the number of pools that will... United States waters of the St. Lawrence River between the international boundary at St. Regis and a line...

  5. 75 FR 54216 - CSX Transportation, Inc.-Abandonment Exemption―in Clay County, KY

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-03

    ...) North Ridge, milepost 0CF212; and (7) Becky Ann2, milepost 0CF217. The line traverses United States... should be sent to CSXT's representative: Kathryn R. Barney, CSX Transportation, Inc., 500 Water Street, J...

  6. Building America Case Study: Assessment of a Hybrid Retrofit Gas Water Heater

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    This project completed a modeling evaluation of a hybrid gas water heater that combines a reduced capacity tankless unit with a downsized storage tank. This product would meet a significant market need by providing a higher efficiency gas water heater solution for retrofit applications while maintaining compatibility with the half-inch gas lines and standard B vents found in most homes. The TRNSYS simulation tool was used to model a base case 0.60 EF atmospheric gas storage water, a 0.82 EF non-condensing gas tankless water heater, an existing (high capacity) hybrid unit on the market, and an alternative hybrid unit withmore » lower storage volume and reduced gas input requirements. Simulations were completed under a 'peak day' sizing scenario with 183 gpd hot water loads in a Minnesota winter climate case. Full-year simulations were then completed in three climates (ranging from Phoenix to Minneapolis) for three hot water load scenarios (36, 57, and 96 gpd). Model projections indicate that the alternative hybrid offers an average 4.5% efficiency improvement relative to the 0.60 EF gas storage unit across all scenarios modeled. The alternative hybrid water heater evaluated does show promise, but the current low cost of natural gas across much of the country and the relatively small incremental efficiency improvement poses challenges in initially building a market demand for the product.« less

  7. Overproduction of Abscisic Acid in Tomato Increases Transpiration Efficiency and Root Hydraulic Conductivity and Influences Leaf Expansion1[OA

    PubMed Central

    Thompson, Andrew J.; Andrews, John; Mulholland, Barry J.; McKee, John M.T.; Hilton, Howard W.; Horridge, Jon S.; Farquhar, Graham D.; Smeeton, Rachel C.; Smillie, Ian R.A.; Black, Colin R.; Taylor, Ian B.

    2007-01-01

    Overexpression of genes that respond to drought stress is a seemingly attractive approach for improving drought resistance in crops. However, the consequences for both water-use efficiency and productivity must be considered if agronomic utility is sought. Here, we characterize two tomato (Solanum lycopersicum) lines (sp12 and sp5) that overexpress a gene encoding 9-cis-epoxycarotenoid dioxygenase, the enzyme that catalyzes a key rate-limiting step in abscisic acid (ABA) biosynthesis. Both lines contained more ABA than the wild type, with sp5 accumulating more than sp12. Both had higher transpiration efficiency because of their lower stomatal conductance, as demonstrated by increases in δ13C and δ18O, and also by gravimetric and gas-exchange methods. They also had greater root hydraulic conductivity. Under well-watered glasshouse conditions, mature sp5 plants were found to have a shoot biomass equal to the wild type despite their lower assimilation rate per unit leaf area. These plants also had longer petioles, larger leaf area, increased specific leaf area, and reduced leaf epinasty. When exposed to root-zone water deficits, line sp12 showed an increase in xylem ABA concentration and a reduction in stomatal conductance to the same final levels as the wild type, but from a different basal level. Indeed, the main difference between the high ABA plants and the wild type was their performance under well-watered conditions: the former conserved soil water by limiting maximum stomatal conductance per unit leaf area, but also, at least in the case of sp5, developed a canopy more suited to light interception, maximizing assimilation per plant, possibly due to improved turgor or suppression of epinasty. PMID:17277097

  8. Overproduction of abscisic acid in tomato increases transpiration efficiency and root hydraulic conductivity and influences leaf expansion.

    PubMed

    Thompson, Andrew J; Andrews, John; Mulholland, Barry J; McKee, John M T; Hilton, Howard W; Horridge, Jon S; Farquhar, Graham D; Smeeton, Rachel C; Smillie, Ian R A; Black, Colin R; Taylor, Ian B

    2007-04-01

    Overexpression of genes that respond to drought stress is a seemingly attractive approach for improving drought resistance in crops. However, the consequences for both water-use efficiency and productivity must be considered if agronomic utility is sought. Here, we characterize two tomato (Solanum lycopersicum) lines (sp12 and sp5) that overexpress a gene encoding 9-cis-epoxycarotenoid dioxygenase, the enzyme that catalyzes a key rate-limiting step in abscisic acid (ABA) biosynthesis. Both lines contained more ABA than the wild type, with sp5 accumulating more than sp12. Both had higher transpiration efficiency because of their lower stomatal conductance, as demonstrated by increases in delta(13)C and delta(18)O, and also by gravimetric and gas-exchange methods. They also had greater root hydraulic conductivity. Under well-watered glasshouse conditions, mature sp5 plants were found to have a shoot biomass equal to the wild type despite their lower assimilation rate per unit leaf area. These plants also had longer petioles, larger leaf area, increased specific leaf area, and reduced leaf epinasty. When exposed to root-zone water deficits, line sp12 showed an increase in xylem ABA concentration and a reduction in stomatal conductance to the same final levels as the wild type, but from a different basal level. Indeed, the main difference between the high ABA plants and the wild type was their performance under well-watered conditions: the former conserved soil water by limiting maximum stomatal conductance per unit leaf area, but also, at least in the case of sp5, developed a canopy more suited to light interception, maximizing assimilation per plant, possibly due to improved turgor or suppression of epinasty.

  9. 36 CFR 14.95 - Authority.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... rights-of-way through public lands and certain reservations of the United States, for electrical plants, poles, and lines for the generation and distribution of electrical power, and for telephone and telegraph purposes, and for pipelines, canals, ditches, water plants, and other purposes to the extent of...

  10. [Comparison of preventive effects of two kinds of dental handpieces on viral contamination at different rotating times].

    PubMed

    Hu, Tao; Zuo, Yu-ling; Zhou, Xue-dong

    2004-08-01

    It has been demonstrated that when a high-speed handpiece stops rotating, negative pressure will form. Thus, contaminating fluid in which there are many kinds of bacteria and viruses from the external environment will retract into various compartments of the handpiece and the dental unit. The purpose of the study is to compare the preventing effect of antisuction designed handpiece and conventional handpiece on viral contamination at different rotating times. Twenty handpieces with or without antisuction device (10 of each) were used in the study. Each handpiece was submerged into 10(-6) microg/microl HBV particle solution rotating 5 and 10 times respectively (every time rotating for 10 seconds). Samples were obtained from the water line and chip air line of the handpieces and examined by RT-PCR. At the same rotating times, there was statistical significance of the viral concentration between the two kinds of handpieces (P < 0.05) . However, there was no statistical significance of the viral concentration between different rotating times in each group (P > 0.05). Contamination taking place in both water and air lines of dental handpiece was not enhanced by increasing the number of rotating times of the handpiece. The antisuction devices installed into the water line and chip air line were demonstrated to prevent viral contamination effectively.

  11. The Minnesota Wetland Evaluation Methodology for the North Central United States

    DTIC Science & Technology

    1988-09-01

    ground water recharge, and other public benefits ." The realization of the enormity of the job led us in the Spring of 1983 to focus these efforts on...looking for drift lines or subwatersheds, routing flows through upstream de- pollen nngsaround trees along the wetland’s banks. tention basins, and...field observa- tion 2, above) to assess the significance of volume tions such as debris lines or pollen rings on trees changes. adjacent to the site

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoeschele, Marc; Weitzel, Elizabeth; Backman, Christine

    This project completed a modeling evaluation of a hybrid gas water heater that combines a reduced capacity tankless unit with a downsized storage tank. This product would meet a significant market need by providing a higher efficiency gas water heater solution for retrofit applications while maintaining compatibility with the 1/2 inch gas lines and standard B vents found in most homes. The TRNSYS simulation tool was used to model a base case 0.60 EF atmospheric gas storage water, a 0.82 EF non-condensing gas tankless water heater, an existing (high capacity) hybrid unit on the market, and an alternative hybrid unitmore » with lower storage volume and reduced gas input requirements. Simulations were completed under a 'peak day' sizing scenario with 183 gpd hot water loads in a Minnesota winter climate case. Full-year simulations were then completed in three climates (ranging from Phoenix to Minneapolis) for three hot water load scenarios (36, 57, and 96 gpd). Model projections indicate that the alternative hybrid offers an average 4.5% efficiency improvement relative to the 0.60 EF gas storage unit across all scenarios modeled. The alternative hybrid water heater evaluated does show promise, but the current low cost of natural gas across much of the country and the relatively small incremental efficiency improvement poses challenges in initially building a market demand for the product.« less

  13. Water Treatment Technologies Inspire Healthy Beverages

    NASA Technical Reports Server (NTRS)

    2013-01-01

    Mike Johnson, a former technician at Johnson Space Center, drew on his expertise as a wastewater engineer to create a line of kombucha-based probiotic drinks. Unpeeled Inc., based in Minneapolis-St. Paul, Minnesota, employs 12 people and has sold more than 6 million units of its NASA-inspired beverage.

  14. 33 CFR 2.20 - Territorial sea baseline.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 1 2012-07-01 2012-07-01 false Territorial sea baseline. 2.20... JURISDICTION Jurisdictional Terms § 2.20 Territorial sea baseline. Territorial sea baseline means the line defining the shoreward extent of the territorial sea of the United States drawn according to the principles...

  15. 33 CFR 2.20 - Territorial sea baseline.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Territorial sea baseline. 2.20... JURISDICTION Jurisdictional Terms § 2.20 Territorial sea baseline. Territorial sea baseline means the line defining the shoreward extent of the territorial sea of the United States drawn according to the principles...

  16. 33 CFR 2.20 - Territorial sea baseline.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Territorial sea baseline. 2.20... JURISDICTION Jurisdictional Terms § 2.20 Territorial sea baseline. Territorial sea baseline means the line defining the shoreward extent of the territorial sea of the United States drawn according to the principles...

  17. 33 CFR 2.20 - Territorial sea baseline.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 1 2013-07-01 2013-07-01 false Territorial sea baseline. 2.20... JURISDICTION Jurisdictional Terms § 2.20 Territorial sea baseline. Territorial sea baseline means the line defining the shoreward extent of the territorial sea of the United States drawn according to the principles...

  18. 33 CFR 2.20 - Territorial sea baseline.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 1 2014-07-01 2014-07-01 false Territorial sea baseline. 2.20... JURISDICTION Jurisdictional Terms § 2.20 Territorial sea baseline. Territorial sea baseline means the line defining the shoreward extent of the territorial sea of the United States drawn according to the principles...

  19. 50 CFR 665.931 - Boundaries.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., Baker, Howland, and Jarvis Islands, Johnston Atoll, Kingman Reef, and Palmyra Atoll, is defined as...″ 0°28′39″ N. (d) Johnston Atoll. The Johnston Atoll unit of the Monument includes the waters and submerged and emergent lands around Johnston Atoll within an area defined by straight lines connecting the...

  20. 50 CFR 665.931 - Boundaries.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., Baker, Howland, and Jarvis Islands, Johnston Atoll, Kingman Reef, and Palmyra Atoll, is defined as...″ 0°28′39″ N. (d) Johnston Atoll. The Johnston Atoll unit of the Monument includes the waters and submerged and emergent lands around Johnston Atoll within an area defined by straight lines connecting the...

  1. Some aspects of analytical chemistry as applied to water quality assurance techniques for reclaimed water: The potential use of X-ray fluorescence spectrometry for automated on-line fast real-time simultaneous multi-component analysis of inorganic pollutants in reclaimed water

    NASA Technical Reports Server (NTRS)

    Ling, A. C.; Macpherson, L. H.; Rey, M.

    1981-01-01

    The potential use of isotopically excited energy dispersive X-ray fluorescence (XRF) spectrometry for automated on line fast real time (5 to 15 minutes) simultaneous multicomponent (up to 20) trace (1 to 10 parts per billion) analysis of inorganic pollutants in reclaimed water was examined. Three anionic elements (chromium 6, arsenic and selenium) were studied. The inherent lack of sensitivity of XRF spectrometry for these elements mandates use of a preconcentration technique and various methods were examined, including: several direct and indirect evaporation methods; ion exchange membranes; selective and nonselective precipitation; and complexation processes. It is shown tha XRF spectrometry itself is well suited for automated on line quality assurance, and can provide a nondestructive (and thus sample storage and repeat analysis capabilities) and particularly convenient analytical method. Further, the use of an isotopically excited energy dispersive unit (50 mCi Cd-109 source) coupled with a suitable preconcentration process can provide sufficient sensitivity to achieve the current mandated minimum levels of detection without the need for high power X-ray generating tubes.

  2. Deformation, warming and softening of Greenland’s ice by refreezing meltwater

    NASA Astrophysics Data System (ADS)

    Bell, Robin E.; Tinto, Kirsteen; Das, Indrani; Wolovick, Michael; Chu, Winnie; Creyts, Timothy T.; Frearson, Nicholas; Abdi, Abdulhakim; Paden, John D.

    2014-07-01

    Meltwater beneath the large ice sheets can influence ice flow by lubrication at the base or by softening when meltwater refreezes to form relatively warm ice. Refreezing has produced large basal ice units in East Antarctica. Bubble-free basal ice units also outcrop at the edge of the Greenland ice sheet, but the extent of refreezing and its influence on Greenland’s ice flow dynamics are unknown. Here we demonstrate that refreezing of meltwater produces distinct basal ice units throughout northern Greenland with thicknesses of up to 1,100 m. We compare airborne gravity data with modelled gravity anomalies to show that these basal units are ice. Using radar data we determine the extent of the units, which significantly disrupt the overlying ice sheet stratigraphy. The units consist of refrozen basal water commonly surrounded by heavily deformed meteoric ice derived from snowfall. We map these units along the ice sheet margins where surface melt is the largest source of water, as well as in the interior where basal melting is the only source of water. Beneath Petermann Glacier, basal units coincide with the onset of fast flow and channels in the floating ice tongue. We suggest that refreezing of meltwater and the resulting deformation of the surrounding basal ice warms the Greenland ice sheet, modifying the temperature structure of the ice column and influencing ice flow and grounding line melting.

  3. Appendices of an appraisal for the use of geothermal energy in state-owned buildings in Colorado. Section D. Durango

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meyer, R.T.; Coe, B.A.; Dick, J.D.

    1981-01-01

    Four state-owned building complexes ahve been evaluated within the city of Durango: The State Fish Hatchery, Fort Lewis College, new State Highway Department Building near the Bodo Industrial Park, and the National Guard Building. Three of the state facilities in Durango are evaluated for geothermal systems on thea ssumption of taking geothermal water from a trunk-line originating at the area northof Durango: State Fish Hatchery, Fort Lewis College and new State Highway Department Building. The National Guard Building is evaluated on the basis of a water-to-air heat pump, with warm water derived from a hypothetical shallow aquifer immediately below themore » building site. Two geothermal options were separately evaluated for Fort Lewis College: a central heat exchanger system for delivery of 145/sup 0/F heating water to the campus buildings and a central heat pump system for boosting the heating water to 200/sup 0/F prior to delivery to the buildings; both systems require the installation of a distribution piping network for the entire campus area. Retrofit engineering for the State Fish Hatchery provides for the installation of a small scale central distribution piping system to the several buildings, a central heat excanger coupled to the geothermal trunk line, and the use of various fan coil and unit heaters for space heating. An option is provided for discharge-mixing the geothermal water into the fish ponds and runs in order to raise the hatchery water temperature a couple degrees for increasing fish production and yield. The heating system for the new State Highway Department Building is redesigned to replace the natural-gas-fired forced-air furnaces with a heat exchanger, hot water fan coils and unit heaters.« less

  4. Design and Installation of Irrigation System for the Expansion of Sugar cane- Industries in Ahvaz, IRAN.

    NASA Astrophysics Data System (ADS)

    Afshari, E.; Afshari, S.

    2005-12-01

    This paper presents achievements of a twelve years ongoing project expansion of sugar cane- industries as a major agricultural development in Ahvaz, IRAN. The entire project is divided in to seven units and each unit provides irrigation water for 30,000 acres of sugar cane farms in Ahwaz. Absou Inc. is one of the consulting firms that is in charge of design and overseeing installation of irrigation system as well as the development of lands for sugar-cane cultivation at one of the units, called Farabi unit .In general, the mission of project is to Pump fresh water from Karoon River and direct it to the sugar cane farm for irrigation. In particular, the task of design and installation include, (1) build a pumping station at Karoon River with capacity of 1271 ft3/sec, (2) transfer water by main channel from Karoon rive to the farm site 19 miles (3) install a secondary pumping stations which direct water from main channel to drainage pipes and provides water for local farms (4) build a secondary channels which carries water with pipe lines with total length of 42 miles and diameter of 16 to 32 inch. (5) install drainage pump stations and collectors (6) level the ground surface and prepare it for irrigation (7) build railroad for carrying sugar canes (23 miles). Thus far, more than 15,000 acres of farm in Farabi unit is under sugar cane cultivation. The presentation will illustrate more details about different aspects of the project including design, installation and construction phases.

  5. Assessment of a Hybrid Retrofit Gas Water Heater

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoeschele, Marc; Weitzel, Elizabeth; Backman, Christine

    2017-02-28

    This project completed a modeling evaluation of a hybrid gas water heater that combines a reduced capacity tankless unit with a downsized storage tank. This product would meet a significant market need by providing a higher efficiency gas water heater solution for retrofit applications while maintaining compatibility with the 1/2 inch gas lines and standard B vents found in most homes. The TRNSYS simulation tool was used to model a base case 0.60 EF atmospheric gas storage water, a 0.82 EF non-condensing gas tankless water heater, an existing (high capacity) hybrid unit on the market, and an alternative hybrid unitmore » with lower storage volume and reduced gas input requirements. Simulations were completed under a 'peak day' sizing scenario with 183 gpd hot water loads in a Minnesota winter climate case. Full-year simulations were then completed in three climates (ranging from Phoenix to Minneapolis) for three hot water load scenarios (36, 57, and 96 gpd). Model projections indicate that the alternative hybrid offers an average 4.5% efficiency improvement relative to the 0.60 EF gas storage unit across all scenarios modeled. The alternative hybrid water heater evaluated does show promise, but the current low cost of natural gas across much of the country and the relatively small incremental efficiency improvement poses challenges in initially building a market demand for the product.« less

  6. Solar hot water system installed at Day's Lodge, Atlanta, Georgia

    NASA Technical Reports Server (NTRS)

    1980-01-01

    The solar energy hot water system installed in the Days Inns of America, Inc., Atlanta, Georgia is described. This system provides for 81 percent of the total hot water demand. There are two separate systems, each serving one building of the lodge (total of 65 suites). The entire system contains only potable city water. The 1024 square feet of Grumman Sunstream Model 332 liquid flat plate collectors and the outside piping drain whenever the collector plates approach freezing or when power is interrupted. Solar heated water from the two above ground cement lined steel tanks (1000 gallon tank) is drawn into the electric Domestic Hot Water (DHW) tanks as hot water is drawn. Electric resistance units in the DHW tanks top off the solar heated water, if needed, to reach thermostat setting.

  7. Contamination of the cold water distribution system of health care facilities by Legionella pneumophila: do we know the true dimension?

    PubMed

    Arvand, M; Jungkind, K; Hack, A

    2011-04-21

    German water guidelines do not recommend routine assessment of cold water for Legionella in healthcare facilities, except if the water temperature at distal sites exceeds 25°C. This study evaluates Legionella contamination in cold and warm water supplies of healthcare facilities in Hesse, Germany, and analyses the relationship between cold water temperature and Legionella contamination. Samples were collected from four facilities, with cases of healthcare-associated Legionnaires' disease or notable contamination of their water supply. Fifty-nine samples were from central lines and 625 from distal sites, comprising 316 cold and 309 warm water samples. Legionella was isolated from central lines in two facilities and from distal sites in four facilities. 17% of all central and 32% of all distal samples were contaminated. At distal sites, cold water samples were more frequently contaminated with Legionella (40% vs 23%, p <0.001) and with higher concentrations of Legionella (≥1,000 colony-forming unit/100 ml) (16% vs 6%, p<0.001) than warm water samples. There was no clear correlation between the cold water temperature at sampling time and the contamination rate. 35% of cold water samples under 20 °C at collection were contaminated. Our data highlight the importance of assessing the cold water supply of healthcare facilities for Legionella in the context of an intensified analysis.

  8. [Spatial-temporal distribution of bigeye tuna Thunnus obesus in the tropical Atlantic Ocean based on Argo data].

    PubMed

    Yang, Sheng-long; Jin, Shao-fei; Hua, Cheng-jun; Dai, Yang

    2015-02-01

    In order to analyze the correlation between spatial-temporal distribution of the bigeye tuna ( Thunnus obesus) and subsurface factors, the study explored the isothermal distribution of subsurface temperatures in the bigeye tuna fishing grounds in the tropical Atlantic Ocean, and built up the spatial overlay chart of the isothermal lines of 9, 12, 13 and 15 °C and monthly CPUE (catch per unit effort) from bigeye tuna long-lines. The results showed that the bigeye tuna mainly distributed in the water layer (150-450 m) below the lower boundary depth of thermocline. At the isothermal line of 12 °C, the bigeye tuna mainly lived in the water layer of 190-260 m, while few individuals were found at water depth more than 400 m. As to the 13 °C isothermal line, high CPUE often appeared at water depth less than 250 m, mainly between 150-230 m, while no CPUE appeared at water depth more than 300 m. The optimum range of subsurface factors calculated by frequency analysis and empirical cumulative distribution function (ECDF) exhibited that the optimum depth range of 12 °C isothermal depth was 190-260 m and the 13 °C isothermal depth was 160-240 m, while the optimum depth difference range of 12 °C isothermal depth was -10 to 100 m and the 13 °C isothermal depth was -40 to 60 m. The study explored the optimum range of subsurface factors (water temperature and depth) that drive horizontal and vertical distribution of bigeye tuna. The preliminary result would help to discover the central fishing ground, instruct fishing depth, and provide theoretical and practical references for the longline production and resource management of bigeye tuna in the Atlantic Ocean.

  9. Analyzing the Molecular Kinetics of Water Spreading on Hydrophobic Surfaces via Molecular Dynamics Simulation.

    PubMed

    Zhao, Lei; Cheng, Jiangtao

    2017-09-07

    In this paper, we report molecular kinetic analyses of water spreading on hydrophobic surfaces via molecular dynamics simulation. The hydrophobic surfaces are composed of amorphous polytetrafluoroethylene (PTFE) with a static contact angle of ~112.4° for water. On the basis of the molecular kinetic theory (MKT), the influences of both viscous damping and solid-liquid retarding were analyzed in evaluating contact line friction, which characterizes the frictional force on the contact line. The unit displacement length on PTFE was estimated to be ~0.621 nm and is ~4 times as long as the bond length of C-C backbone. The static friction coefficient was found to be ~[Formula: see text] Pa·s, which is on the same order of magnitude as the dynamic viscosity of water, and increases with the droplet size. A nondimensional number defined by the ratio of the standard deviation of wetting velocity to the characteristic wetting velocity was put forward to signify the strength of the inherent contact line fluctuation and unveil the mechanism of enhanced energy dissipation in nanoscale, whereas such effect would become insignificant in macroscale. Moreover, regarding a liquid droplet on hydrophobic or superhydrophobic surfaces, an approximate solution to the base radius development was derived by an asymptotic expansion approach.

  10. The effects of electric power industry restructuring on the safety of nuclear power plants in the United States

    NASA Astrophysics Data System (ADS)

    Butler, Thomas S.

    Throughout the United States the electric utility industry is restructuring in response to federal legislation mandating deregulation. The electric utility industry has embarked upon an extraordinary experiment by restructuring in response to deregulation that has been advocated on the premise of improving economic efficiency by encouraging competition in as many sectors of the industry as possible. However, unlike the telephone, trucking, and airline industries, the potential effects of electric deregulation reach far beyond simple energy economics. This dissertation presents the potential safety risks involved with the deregulation of the electric power industry in the United States and abroad. The pressures of a competitive environment on utilities with nuclear power plants in their portfolio to lower operation and maintenance costs could squeeze them to resort to some risky cost-cutting measures. These include deferring maintenance, reducing training, downsizing staff, excessive reductions in refueling down time, and increasing the use of on-line maintenance. The results of this study indicate statistically significant differences at the .01 level between the safety of pressurized water reactor nuclear power plants and boiling water reactor nuclear power plants. Boiling water reactors exhibited significantly more problems than did pressurized water reactors.

  11. Characterization of a customized calibration unit for continuous measurements of the isotopic composition of water vapor

    NASA Astrophysics Data System (ADS)

    Moro, Giovanni; Zannoni, Daniele; Dreossi, Giuliano; Stenni, Barbara

    2017-04-01

    The objective of this work is the development, standardization and creation of a method to carry out continuous measurement of oxygen and hydrogen isotopic composition of the atmospheric water vapor using a wavelength-scanned cavity ring down spectroscopy (WS-CRDS) instrument produced by Picarro, L1102-i model. Some technical improvements of the standard instrument configuration have been made to create three different inlet gas lines: a "standard" line, a calibration line and a line connected with the external sampler. The calibration line is composed of a syringe-pump that continuously injects standard water into a steel tee heated at the temperature of 170°C and flushed with dry nitrogen gas. In this way, instantaneous and complete vaporization of the standard water takes place. The resulting steam is characterized by a well-defined composition in δD e δ18O values. To allow comparison with other international data, we have characterized the individual instrumental response to variation of the isotopic composition of the water vapor. Several humidity-isotope response functions (6000-26000 ppmv) have been estimated with three different internal standards (0.35‰ -8.75‰ -29.11‰ and -40.28‰ for δ18O; 2.31‰ -58.91‰ -222.19‰ and -317.78‰ for δD). Moreover, we have measured the instrumental drift at regular time intervals to apply the opportune corrections to instrument data. The setup has been tested using a 3.5 day continuous measurements carried out with the Picarro sampling the water vapor outside our campus in Venice and parallel sampling using the classical cryogenic trapping procedure, obtaining excellent results. Furthermore, our analysis technique has given good results for the standards with values which are similar to those obtained with the isotope ratio mass spectrometry (IRMS) technique.

  12. User's manual for the National Water Information System of the U.S. Geological Survey: Automated Data Processing System (ADAPS)

    USGS Publications Warehouse

    ,

    2003-01-01

    The Automated Data Processing System (ADAPS) was developed for the processing, storage, and retrieval of water data, and is part of the National Water Information System (NWIS) developed by the U.S. Geological Survey. NWIS is a distributed water database in which data can be processed over a network of computers at U.S. Geological Survey offices throughout the United States. NWIS comprises four subsystems: ADAPS, the Ground-Water Site Inventory System (GWSI), the Water-Quality System (QWDATA), and the Site-Specific Water-Use Data System (SWUDS). This section of the NWIS User's Manual describes the automated data processing of continuously recorded water data, which primarily are surface-water data; however, the system also allows for the processing of water-quality and ground-water data. This manual describes various components and features of the ADAPS, and provides an overview of the data processing system and a description of the system framework. The components and features included are: (1) data collection and processing, (2) ADAPS menus and programs, (3) command line functions, (4) steps for processing station records, (5) postprocessor programs control files, (6) the standard format for transferring and entering unit and daily values, and (7) relational database (RDB) formats.

  13. LLNL Experimental Test Site (Site 300) Potable Water System Operations Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ocampo, R. P.; Bellah, W.

    The existing Lawrence Livermore National Laboratory (LLNL) Site 300 drinking water system operation schematic is shown in Figures 1 and 2 below. The sources of water are from two Site 300 wells (Well #18 and Well #20) and San Francisco Public Utilities Commission (SFPUC) Hetch-Hetchy water through the Thomas shaft pumping station. Currently, Well #20 with 300 gallons per minute (gpm) pump capacity is the primary source of well water used during the months of September through July, while Well #18 with 225 gpm pump capacity is the source of well water for the month of August. The well watermore » is chlorinated using sodium hypochlorite to provide required residual chlorine throughout Site 300. Well water chlorination is covered in the Lawrence Livermore National Laboratory Experimental Test Site (Site 300) Chlorination Plan (“the Chlorination Plan”; LLNL-TR-642903; current version dated August 2013). The third source of water is the SFPUC Hetch-Hetchy Water System through the Thomas shaft facility with a 150 gpm pump capacity. At the Thomas shaft station the pumped water is treated through SFPUC-owned and operated ultraviolet (UV) reactor disinfection units on its way to Site 300. The Thomas Shaft Hetch- Hetchy water line is connected to the Site 300 water system through the line common to Well pumps #18 and #20 at valve box #1.« less

  14. Lawrence Livermore National Laboratory Experimental Test Site (Site 300) Potable Water System Operations Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ocampo, Ruben P.; Bellah, Wendy

    The existing Lawrence Livermore National Laboratory (LLNL) Site 300 drinking water system operation schematic is shown in Figures 1 and 2 below. The sources of water are from two Site 300 wells (Well #18 and Well #20) and San Francisco Public Utilities Commission (SFPUC) Hetch-Hetchy water through the Thomas shaft pumping station. Currently, Well #20 with 300 gallons per minute (gpm) pump capacity is the primary source of well water used during the months of September through July, while Well #18 with 225 gpm pump capacity is the source of well water for the month of August. The well watermore » is chlorinated using sodium hypochlorite to provide required residual chlorine throughout Site 300. Well water chlorination is covered in the Lawrence Livermore National Laboratory Experimental Test Site (Site 300) Chlorination Plan (“the Chlorination Plan”; LLNL-TR-642903; current version dated August 2013). The third source of water is the SFPUC Hetch-Hetchy Water System through the Thomas shaft facility with a 150 gpm pump capacity. At the Thomas shaft station the pumped water is treated through SFPUC-owned and operated ultraviolet (UV) reactor disinfection units on its way to Site 300. The Thomas Shaft Hetch- Hetchy water line is connected to the Site 300 water system through the line common to Well pumps #18 and #20 at valve box #1.« less

  15. Economic feasibility study of residential and commercial heating using existing water supply systems. Final report June 1, 1979 - August 15, 1979

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pitts, Donald R.; Looper, Marshall G.

    1979-08-15

    A study of the use of a low-to-moderate temperature hydrothermal resource for space heating a 140-home residential community has been undertake. The approach centers on use of the existing culinary/potable water supply system to supply heated water to the homes, the culinary water being heated at a single pumping station and then distributed throughout the community through uninsulated, buried water mains. The heated potable water is pumped through individual house water-to-air heat exchangers using sealed, magnetic-drive house pumps and returned to the street distribution lines. These house heat exchangers are either add-on, wall mounted, convective heating units or coils addedmore » to existing forced air heating systems.« less

  16. Development of a Small Thermoelectric Generators Prototype for Energy Harvesting from Low Temperature Waste Heat at Industrial Plant.

    PubMed

    Chiarotti, Ugo; Moroli, Valerio; Menchetti, Fernando; Piancaldini, Roberto; Bianco, Loris; Viotto, Alberto; Baracchini, Giulia; Gaspardo, Daniele; Nazzi, Fabio; Curti, Maurizio; Gabriele, Massimiliano

    2017-03-01

    A 39-W thermoelectric generator prototype has been realized and then installed in industrial plant for on-line trials. The prototype was developed as an energy harvesting demonstrator using low temperature cooling water waste heat as energy source. The objective of the research program is to measure the actual performances of this kind of device working with industrial water below 90 °C, as hot source, and fresh water at a temperature of about 15 °C, as cold sink. The article shows the first results of the research program. It was verified, under the tested operative conditions, that the produced electric power exceeds the energy required to pump the water from the hot source and cold sink to the thermoelectric generator unit if they are located at a distance not exceeding 50 m and the electric energy conversion efficiency is 0.33%. It was calculated that increasing the distance of the hot source and cold sink to the thermoelectric generator unit to 100 m the produced electric energy equals the energy required for water pumping, while reducing the distance of the hot source and cold sink to zero meters the developed unit produces an electric energy conversion efficiency of 0.61%.

  17. Downhole steam generator with improved preheating/cooling features

    DOEpatents

    Donaldson, A. Burl; Hoke, Donald E.; Mulac, Anthony J.

    1983-01-01

    An apparatus for downhole steam generation employing dual-stage preheaters for liquid fuel and for the water. A first heat exchange jacket for the fuel surrounds the fuel/oxidant mixing section of the combustor assembly downstream of the fuel nozzle and contacts the top of the combustor unit of the combustor assembly, thereby receiving heat directly from the combustion of the fuel/oxidant. A second stage heat exchange jacket surrounds an upper portion of the oxidant supply line adjacent the fuel nozzle receiving further heat from the compression heat which results from pressurization of the oxidant. The combustor unit includes an inner combustor sleeve whose inner wall defines the combustion zone. The inner combustor sleeve is surrounded by two concentric water channels, one defined by the space between the inner combustor sleeve and an intermediate sleeve, and the second defined by the space between the intermediate sleeve and an outer cylindrical housing. The channels are connected by an annular passage adjacent the top of the combustor assembly and the countercurrent nature of the water flow provides efficient cooling of the inner combustor sleeve. An annular water ejector with a plurality of nozzles is provided to direct water downwardly into the combustor unit at the boundary of the combustion zone and along the lower section of the intermediate sleeve.

  18. Downhole steam generator with improved preheating/cooling features. [Patent application

    DOEpatents

    Donaldson, A.B.; Hoke, D.E.; Mulac, A.J.

    1980-10-10

    An apparatus is described for downhole steam generation employing dual-stage preheaters for liquid fuel and for the water. A first heat exchange jacket for the fuel surrounds the fuel/oxidant mixing section of the combustor assembly downstream of the fuel nozzle and contacts the top of the combustor unit of the combustor assembly, thereby receiving heat directly from the combustion of the fuel/oxidant. A second stage heat exchange jacket surrounds an upper portion of the oxidant supply line adjacent the fuel nozzle receiving further heat from the compression heat which results from pressurization of the oxidant. The combustor unit includes an inner combustor sleeve whose inner wall defines the combustion zone. The inner combustor sleeve is surrounded by two concentric water channels, one defined by the space between the inner combustor sleeve and an intermediate sleeve, and the second defined by the space between the intermediate sleeve and an outer cylindrical housing. The channels are connected by an annular passage adjacent the top of the combustor assembly and the countercurrent nature of the water flow provides efficient cooling of the inner combustor sleeve. An annular water ejector with a plurality of nozzles is provided to direct water downwardly into the combustor unit at the boundary of the combustion zone and along the lower section of the intermediate sleeve.

  19. Photosynthetic Response of Poplars (Populus) to Climatic Stressors: Investigating Isoprene's Role in Increasing Tolerance to Temperature and Atmospheric Water Stress in Arizona

    NASA Astrophysics Data System (ADS)

    Pfeiffer, A. W.; Minor, R. L.; Heard, M. M.; Barron-Gafford, G.

    2014-12-01

    The southwestern United States is expected to become warmer and drier under future climate projections. The way in which plant and ecosystems respond to these changes is valuable for predicting carbon and water cycling, ecosystem resilience, phenology, and future agriculture, including biofuel production. We examined the interacting effects of dominant climate stressors--vapor pressure deficit (VPD) and temperature--on photosynthesis. Specifically, we tested whether or not plant production of the terpene isoprene imparts heat and water-stress tolerance. Within an experimental common garden of poplars (Populus) at University of Arizona's Biosphere 2 we measured four separate genetic lines - two that retained isoprene production capacity and two that had this gene "knocked out". VPD was altered at temperatures of 30, 35, and 40C to present both heat and aridity stresses. Maximum photosynthetic capacity (Amax), the VPD at which Amax occurred (VPDopt), and the VPD range between Amax and ninety percent of Amax (Ω90) were calculated to quantify how VPD differentially affected the lines. Amax was significantly lower in knockout lines than in control lines. Moreover, the difference in Amax between lines increased from 19.3% at 30C to 28.4% at 35C to 39.0% at 40C, indicating that trees without isoprene production are less equipped to handle hot and dry conditions. Ω90 and VPDopt response were not the same, though. Isoprene knockouts had significantly higher VPD optimums (1.9749 kPA vs. 1.6451 kPa) compared to isoprene-producing lines. Although maximum photosynthesis is diminished without isoprene production under water and heat stress, isoprene knockout lines were still fairly active at a high VPD and under a wide range of VPD conditions. Beyond advancing our basic understanding of plant ecophysiology, these results will inform the potential use of poplars as a source of biofuel production across a range of current and projected climate conditions.

  20. 33 CFR 151.2025 - What definitions apply to this subpart?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... overflowing the tank from the top until three full volumes of water has been changed—to minimize the number of... line of the territorial sea of the United States seaward 200 miles, and the equivalent zone of Canada... Puerto Rico, Guam, American Samoa, the Virgin Islands, and the Trust Territory of the Pacific Islands...

  1. 33 CFR 151.2025 - What definitions apply to this subpart?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... overflowing the tank from the top until three full volumes of water has been changed—to minimize the number of... line of the territorial sea of the United States seaward 200 miles, and the equivalent zone of Canada... Puerto Rico, Guam, American Samoa, the Virgin Islands, and the Trust Territory of the Pacific Islands...

  2. Lining seam elimination algorithm and surface crack detection in concrete tunnel lining

    NASA Astrophysics Data System (ADS)

    Qu, Zhong; Bai, Ling; An, Shi-Quan; Ju, Fang-Rong; Liu, Ling

    2016-11-01

    Due to the particularity of the surface of concrete tunnel lining and the diversity of detection environments such as uneven illumination, smudges, localized rock falls, water leakage, and the inherent seams of the lining structure, existing crack detection algorithms cannot detect real cracks accurately. This paper proposed an algorithm that combines lining seam elimination with the improved percolation detection algorithm based on grid cell analysis for surface crack detection in concrete tunnel lining. First, check the characteristics of pixels within the overlapping grid to remove the background noise and generate the percolation seed map (PSM). Second, cracks are detected based on the PSM by the accelerated percolation algorithm so that the fracture unit areas can be scanned and connected. Finally, the real surface cracks in concrete tunnel lining can be obtained by removing the lining seam and performing percolation denoising. Experimental results show that the proposed algorithm can accurately, quickly, and effectively detect the real surface cracks. Furthermore, it can fill the gap in the existing concrete tunnel lining surface crack detection by removing the lining seam.

  3. Subtidal currents over the central California slope: Evidence for offshore veering of the undercurrent and for direct, wind-driven slope currents

    USGS Publications Warehouse

    Noble, M.A.; Ramp, S.R.

    2000-01-01

    In February 1991, an array of six current-meter moorings was deployed for one year across the central California outer shelf and slope. The main line of the array extended 30 km offshore of the shelf break, out to water depths of 1400 m. A more sparsely-instrumented line, displaced 30 km to the northwest, extended 14 km offshore. Though shorter, the northern line spanned similar water depths because the gradient of the topography steepened in the northern region. A poleward flow pattern, typical of the California undercurrent, was seen across both lines in the array over most of the year. The poleward flow was surface intensified. In general, the portion of the undercurrent that crossed the southern line had larger amplitudes and penetrated more deeply into the water column than the portion that crossed the northern line. Transport over the year ranged from 0 to 2.5 Sverdrups (Sv) poleward across the southern line; 0 to 1 Sv poleward across the northern line. We suggest the difference in transport was caused by topographic constraints, which tended to force the poleward flow offshore of the northern measurement sites. The slope of the topography steepened too abruptly to allow the poleward flow to follow isobaths when currents were strong. When current velocities lessened, a more coherent flow pattern was seen across both lines in the array. In general, the poleward flow patterns in the undercurrent were not affected by local winds or by the local alongshore pressure gradient. Nor was a strong seasonal pattern evident. Rather unexpectedly, a small but statistically significant fraction of the current variance over the mid- and outer slope was driven by the surface wind stress. An alongshelf wind stress caused currents to flow along the slope, parallel to the wind field, down to depths of 400 m below the surface and out to distances of 2 Rossby radii past the shelf break. The transfer functions were weak, 3-4 cm/s per dyn cm-2, but comparable to wind-driven current amplitudes of 4-6 cm/s per unit wind stress over the middle shelf. Equatorward, alongshelf winds also caused water from 200-300 m over the slope to upwell onto the shelf as the surface water moved offshore.

  4. Development of a 14-digit Hydrologic Unit Code Numbering System for South Carolina

    USGS Publications Warehouse

    Bower, David E.; Lowry, Claude; Lowery, Mark A.; Hurley, Noel M.

    1999-01-01

    A Hydrologic Unit Map showing the cataloging units, watersheds, and subwatersheds of South Carolina has been developed by the U.S. Geological Survey in cooperation with the South Carolina Department of Health and Environmental Control, funded through a U.S. Environmental Protection Agency 319 Grant, and the U.S. Department of Agriculture, Natural Resources Conservation Service. These delineations represent 8-, 11-, and 14-digit Hydrologic Unit Codes, respectively. This map presents information on drainage, hydrography, and hydrologic boundaries of the water-resources regions, subregions, accounting units, cataloging units, watersheds, and subwatersheds. The source maps for the basin delineations are 1:24,000-scale 7.5-minute series topographic maps and the base maps are from 1:100,000-scale Digital Line Graphs; however, the data are published at a scale of 1:500,000. In addition, an electronic version of the data is provided on a compact disc.Of the 1,022 subwatersheds delineated for this project, 1,004 range in size from 3,000 to 40,000 acres (4.69 to 62.5 square miles). Seventeen subwatersheds are smaller than 3,000 acres and one subwatershed, located on St. Helena Island, is larger than 40,000 acres.This map and its associated codes provide a standardized base for use by water-resource managers and planners in locating, storing, retrieving, and exchanging hydrologic data. In addition, the map can be used for cataloging water-data acquisition activities, geographically organizing hydrologic data, and planning and describing water-use and related land-use activities.

  5. Rio Grande valley Colorado new Mexico and Texas

    USGS Publications Warehouse

    Ellis, Sherman R.; Levings, Gary W.; Carter, Lisa F.; Richey, Steven F.; Radell, Mary Jo

    1993-01-01

    Two structural settings are found in the study unit: alluvial basins and bedrock basins. The alluvial basins can have through-flowing surface water or be closed basins. The discussion of streamflow and water quality for the surface-water system is based on four river reaches for the 750 miles of the main stem. the quality of the ground water is affected by both natural process and human activities and by nonpoint and point sources. Nonpoint sources for surface water include agriculture, hydromodification, and mining operations; point sources are mainly discharge from wastewater treatment plants. Nonpoint sources for ground water include agriculture and septic tanks and cesspools; point sources include leaking underground storage tanks, unlined or manure-lined holding ponds used for disposal of dairy wastes, landfills, and mining operations.

  6. Dewatering of contaminated river sediments

    NASA Technical Reports Server (NTRS)

    Church, Ronald H.; Smith, Carl W.; Scheiner, Bernard J.

    1994-01-01

    Dewatering of slurries has been successfully accomplished by the proper use of polymers in flocculating the fine particulate matter suspended in mineral processing streams. The U.S. Bureau of Mines (USBM) entered into a cooperative research effort with the U.S. Army Corps of Engineers (Corps) for the purpose of testing and demonstrating the applicability of mining flocculation technology to dredging activities associated with the removal of sediments from navigable waterways. The Corps has the responsibility for maintaining the navigable waterways in the United States. Current technology relies primarily on dredging operations which excavate the material from the bottom of waterways. The Corps is testing new dredging technology which may reduce resuspension of sediments by the dredging operation. Pilot plant dredging equipment was tested by the Corps which generated larger quantities of water when compared to conventional equipment, such as the clam shell. The transportation of this 'excess' water adds to the cost of sediment removal. The process developed by the USBM consists of feed material from the barge being pumped through a 4-in line by a centrifugal pump and exiting through a 4-in PVC delivery system. A 1,000-gal fiberglass tank was used to mix the polymer concentrate. The polymer was pumped through a 1-in line using a variable speed progressive cavity pump and introduced to the 4-in feed line prior to passing through a 6-in by 2-ft static mixer. The polymer/feed slurry travels to the clarifying tank where the flocculated material settled to the bottom and allowed 'clean' water to exit the overflow. A pilot scale flocculation unit was operated on-site at the Corps' 'Confined Disposal Facility' in Buffalo, NY.

  7. Extending the application of deuterium excess as a tracer in surface and groundwaters

    NASA Astrophysics Data System (ADS)

    Hurst, S.; Krishnamurthy, R. V.

    2017-12-01

    Stable isotopes of surface and ground waters provide invaluable information on the processes involved in their genesis. A starting point in these applications is the relationship between hydrogen (δ2H) and oxygen (δ18O), exemplified in the so-called Global Meteoric Water Line where δ2H=8δ18O+10 [1]. From this line Dansgaard [2] defined the parameter deuterium excess where d=δ2H-8δ18O. Generally, the d-excess value is fixed at the source, predominantly the equatorial oceans and retained. At an average humidity of about 85% the expected d-excess value is 10. Deviations indicate secondary changes in the air mass or a water body thus making d-excess a useful geophysical tracer. For instance, evaporation results in a higher d-excess in the vapor. Mixing of this water vapor with overhead air mass results in precipitation exhibiting d-excess values higher than Global Meteoric Water Line [3]. Alternatively, the fraction of liquid remaining will have low d-excess and in extreme cases negative d-excess. In this case a plot of d-excess-δ2H will give a straight line with a negative slope. This can be demonstrated from pan evaporation experiments [4]. Deviation from a perfect straight line on the d-excess-δ2H plot indicates a combination of mixing from various source waters and evaporation. This study will discuss various case studies from multiple environments applying this approach using d-excess. References [1] Craig, H. Standard for Reporting Concentrations of Deuterium and Oxygen-18 in Natural Waters. Science 133, 1833-1834 (1961). [2] Dansgaard, W. Stable isotopes in precipitation. Tellus A 16: 436-468 (1964). [3] Machavaram, M. &, Krishnamurthy, R.V. Earth surface evaporative process: a case study from the Great Lakes region of the United States based on deuterium excess in precipitation. Geochim. et Cosmochem. Acta 59, 4279-4283 (1995). [4] Simpson, H.J., Hamza, M.S., & White, J.W.C. Evaporative enrichment of deuterium and 18O in arid zone irrigation. IAEA, 241-256 (1987).

  8. Seismic-reflection data from R/V FARNELLA cruises FRNL82-7, FRNL85-1, FRNL85-2, and FRNL85-3A in the U.S. Gulf of Mexico EEZ

    USGS Publications Warehouse

    Twichell, D.C.; McGregor, B.A.; Lubinski, D.J.

    1989-01-01

    During the winter of 1982 and the summer and early fall of 1985, the U.S. Geological Survey (USGS) in cooperation with the Institute of Oceanographic Sciences of the United Kingdom collected approximately 30,508 line kilometers of seismic-reflection data in the U.S. Gulf of Mexico Exclusive Economic Zone (EEZ) as part of a USGS program to map the EEZ. In water depths exceeding 3,000 m, survey line spacing was about 25 km and gradually decreased to about 5 km in 250 m water depths. No areas were surveyed with depths shallower than 250 m. Orientation of the tracklines was in general parallel to the trend of the bathymetric contours (Figs. 1, 2, 3, and 4).

  9. Assessing Tsunami Vulnerabilities of Geographies with Shallow Water Equations

    NASA Technical Reports Server (NTRS)

    Aras, Rifat; Shen, Yuzhong

    2012-01-01

    Tsunami preparedness is crucial for saving human lives in case of disasters that involve massive water movement. In this work, we develop a framework for visual assessment of tsunami preparedness of geographies. Shallow water equations (also called Saint Venant equations) are a set of hyperbolic partial differential equations that are derived by depth-integrating the Navier-Stokes equations and provide a great abstraction of water masses that have lower depths compared to their free surface area. Our specific contribution in this study is to use Microsoft's XNA Game Studio to import underwater and shore line geographies, create different tsunami scenarios, and visualize the propagation of the waves and their impact on the shore line geography. Most importantly, we utilized the computational power of graphical processing units (GPUs) as HLSL based shader files and delegated all of the heavy computations to the GPU. Finally, we also conducted a validation study, in which we have tested our model against a controlled shallow water experiment. We believe that such a framework with an easy to use interface that is based on readily available software libraries, which are widely available and easily distributable, would encourage not only researchers, but also educators to showcase ideas.

  10. Microbial contamination in dental unit waterlines: comparison between Er:YAG laser and turbine lines.

    PubMed

    Sacchetti, Rossella; Baldissarri, Augusto; De Luca, Giovanna; Lucca, Paola; Stampi, Serena; Zanetti, Franca

    2006-01-01

    The investigation was carried out by evaluating the microbiological characteristics of the water before and after treatment with Er:YAG laser and turbine. The study was carried out in 2 dental surgeries. In both cases the laser and dental units were served by two independent circuits, fed by the same potable tap water. Samples were taken from the water supplying and the water leaving the turbine and laser before and after treatment on the same patient. Total heterotrophic plate count was measured at 36 degrees C and at 22 degrees C, and the presence of Staphylococcus species and non-fermenting Gram negative bacteria was investigated. Bacterial contamination was found within the circuit, especially in the laser device. Pseudomonas aeruginosa was detected in only 1 sample of supply water, in 11.1 % and in 19.4 % of the samples from the turbine and the laser respectively. No evidence of Staphylococcus aureus was found. The contamination of supply water was low, whereas that of the water leaving the handpieces of the 2 devices was high, especially in the laser. Attention should be paid to the control of the water leaving laser devices, given the increasingly wide use of such instruments in dental treatment exposed to risk of infection.

  11. Conceptual design study of geothermal district heating of a thirty-house subdivision in Elko, Nevada, using existing water-distribution systems, Phase III. Final technical report, October 1, 1979-September 30, 1980

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pitts, D.R.

    1980-09-30

    A conceptual design study for district heating of a 30-home subdivision located near the southeast extremity of the city of Elko, Nevada is presented. While a specific residential community was used in the study, the overall approach and methodologies are believed to be generally applicable for a large number of communities where low temperature geothermal fluid is available. The proposed district heating system utilizes moderate temperature, clean domestic water and existing community culinary water supply lines. The culinary water supply is heated by a moderate temperature geothermal source using a single heat exchanger at entry to the subdivision. The heatedmore » culinary water is then pumped to the houses in the community where energy is extracted by means of a water supplied heat pump. The use of heat pumps at the individual houses allows economic heating to result from supply of relatively cool water to the community, and this precludes the necessity of supplying objectionably hot water for normal household consumption use. Each heat pump unit is isolated from the consumptive water flow such that contamination of the water supply is avoided. The community water delivery system is modified to allow recirculation within the community, and very little rework of existing water lines is required. The entire system coefficient of performance (COP) for a typical year of heating is 3.36, exclusive of well pumping energy.« less

  12. Saline aquifer mapping project in the southeastern United States

    USGS Publications Warehouse

    Williams, Lester J.; Spechler, Rick M.

    2011-01-01

    In 2009, the U.S. Geological Survey initiated a study of saline aquifers in the southeastern United States to evaluate the potential use of brackish or saline water from the deeper portions of the Floridan aquifer system and the underlying Coastal Plain aquifer system (Fig. 1). The objective of this study is to improve the overall understanding of the available saline water resources for potential future development. Specific tasks are to (1) develop a digital georeferenced database of borehole geophysical data to enable analysis and characterization of saline aquifers (see locations in Fig. 1), (2) identify and map the regional extent of saline aquifer systems and describe the thickness and character of hydrologic units that compose these systems, and (3) delineate salinity variations at key well sites and along section lines to provide a regional depiction of the freshwater-saltwater interfaces. Electrical resistivity and induction logs, coupled with a variety of different porosity logs (sonic, density, and neutron), are the primary types of borehole geophysical logs being used to estimate the water quality in brackish and saline formations. The results from the geophysical log calculations are being compared to available water-quality data obtained from water wells and from drill-stem water samples collected in test wells. Overall, the saline aquifer mapping project is helping to improve the understanding of saline water resources in the area. These aquifers may be sources of large quantities of water that could be treated by using reverse osmosis or similar technologies, or they could be used for aquifer storage and recovery systems.

  13. Extreme-ultraviolet and electron beam lithography processing using water developable resist material

    NASA Astrophysics Data System (ADS)

    Takei, Satoshi

    2017-08-01

    In order to achieve the use of pure water in the developable process of extreme-ultraviolet and electron beam lithography, instead of conventionally used tetramethylammonium hydroxide and organic solvents, a water developable resist material was designed and developed. The water-developable resist material was derived from woody biomass with beta-linked disaccharide unit for environmental affair, safety, easiness of handling, and health of the working people. 80 nm dense line patterning images with exposure dose of 22 μC/cm2 and CF4 etching selectivity of 1.8 with hardmask layer were provided by specific process conditions. The approach of our water-developable resist material will be one of the most promising technologies ready to be investigated into production of medical device applications.

  14. Statistical procedures for determination and verification of minimum reporting levels for drinking water methods.

    PubMed

    Winslow, Stephen D; Pepich, Barry V; Martin, John J; Hallberg, George R; Munch, David J; Frebis, Christopher P; Hedrick, Elizabeth J; Krop, Richard A

    2006-01-01

    The United States Environmental Protection Agency's Office of Ground Water and Drinking Water has developed a single-laboratory quantitation procedure: the lowest concentration minimum reporting level (LCMRL). The LCMRL is the lowest true concentration for which future recovery is predicted to fall, with high confidence (99%), between 50% and 150%. The procedure takes into account precision and accuracy. Multiple concentration replicates are processed through the entire analytical method and the data are plotted as measured sample concentration (y-axis) versus true concentration (x-axis). If the data support an assumption of constant variance over the concentration range, an ordinary least-squares regression line is drawn; otherwise, a variance-weighted least-squares regression is used. Prediction interval lines of 99% confidence are drawn about the regression. At the points where the prediction interval lines intersect with data quality objective lines of 50% and 150% recovery, lines are dropped to the x-axis. The higher of the two values is the LCMRL. The LCMRL procedure is flexible because the data quality objectives (50-150%) and the prediction interval confidence (99%) can be varied to suit program needs. The LCMRL determination is performed during method development only. A simpler procedure for verification of data quality objectives at a given minimum reporting level (MRL) is also presented. The verification procedure requires a single set of seven samples taken through the entire method procedure. If the calculated prediction interval is contained within data quality recovery limits (50-150%), the laboratory performance at the MRL is verified.

  15. The biofilm-controlling functions of rechargeable antimicrobial N-halamine dental unit waterline tubing.

    PubMed

    Porteous, Nuala; Schoolfield, John; Luo, Jie; Sun, Yuyu

    2011-01-01

    A study was conducted to test the biofilm-controlling functions of N-halamine tubing over an eight-month period. A laboratory system, simulating a teaching dental clinic, was used to test rechargeable N-halamine tubing (T) compared to an untreated control (C) using the unit manufacturer's tubing. For the long-term study, a recharged tubing (RC) treated with bleach was used to compare with the test (T) and the control (C) tubing. Source tap water was cycled through the lines at 1.4 mL/minute, five minutes on and 25 minutes off, eight hours/day, five days/week. Every three weeks, samples of effluent, recovered adherent bacteria from inside tubing surfaces, and SEM images were examined for bacterial and biofilm growth. After sampling, a recharging solution of chlorine bleach (1 : 10 dilution) was run through T and RC lines, left overnight, and rinsed out the next morning. One-way ANOVAs and Spearman correlations were performed to detect significant differences for T, RC, and C, and determine significance with time period and source water, respectively. Mean log CFU/mL for C effluent > T (p = 0.028), and C tubing > T (p = 0.035). Spearman correlations were significant between effluent and source water level for T (rho = 0.817), and T tubing (0.750); between RC tubing and source water level (rho = 0.836), and time (rho = 0.745); and between C and time (rho = 0.873). SEM imaging confirmed the presence of biofilm inside RC and C, but not inside T. N-halamine tubing completely inhibited biofilm formation without negatively affecting the physical properties of the effluent water. Further research on N-halamine tubing using a pure water source is recommended, as T effluent bacterial levels reflected the source tap water quality and proliferation of planktonic bacteria with no biofilm activity.

  16. The Biofilm-Controlling Functions of Rechargeable Antimicrobial N-halamine Dental Unit Waterline Tubing

    PubMed Central

    Porteous, Nuala; Schoolfield, John; Luo, Jie; Sun, Yuyu

    2015-01-01

    Objective A study was conducted to test the biofilm-controlling functions of N-halamine tubing over an eight-month period. Methods A laboratory system, simulating a teaching dental clinic, was used to test rechargeable N-halamine tubing (T) compared to an untreated control (C) using the unit manufacturer’s tubing. For the long-term study, a recharged tubing (RC) treated with bleach was used to compare with the test (T) and the control (C) tubing. Source tap water was cycled through the lines at 1.4 mL/minute, five minutes on and 25 minutes off, eight hours/day, five days/week. Every three weeks, samples of effluent, recovered adherent bacteria from inside tubing surfaces, and SEM images were examined for bacterial and biofilm growth. After sampling, a recharging solution of chlorine bleach (1:10 dilution) was run through T and RC lines, left overnight, and rinsed out the next morning. One-way ANOVAs and Spearman correlations were performed to detect significant differences for T, RC, and C, and determine significance with time period and source water, respectively. Results Mean log CFU/mL for C effluent > T (p = 0.028), and C tubing > T (p = 0.035). Spearman correlations were significant between effluent and source water level for T (rho = 0.817), and T tubing (0.750); between RC tubing and source water level (rho = 0.836), and time (rho = 0.745); and between C and time (rho = 0.873). SEM imaging confirmed the presence of biofilm inside RC and C, but not inside T. Conclusion N-halamine tubing completely inhibited biofilm formation without negatively affecting the physical properties of the effluent water. Further research on N-halamine tubing using a pure water source is recommended, as T effluent bacterial levels reflected the source tap water quality and proliferation of planktonic bacteria with no biofilm activity. PMID:22403982

  17. Letter Report: Stable Hydrogen and Oxygen Isotope Analysis of B-Complex Perched Water Samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Brady D.; Moran, James J.; Nims, Megan K.

    Fine-grained sediments associated with the Cold Creek Unit at Hanford have caused the formation of a perched water aquifer in the deep vadose zone at the B Complex area, which includes waste sites in the 200-DV-1 Operable Unit and the single-shell tank farms in Waste Management Area B-BX-BY. High levels of contaminants, such as uranium, technetium-99, and nitrate, make this aquifer a continuing source of contamination for the groundwater located a few meters below the perched zone. Analysis of deuterium ( 2H) and 18-oxygen ( 18O) of nine perched water samples from three different wells was performed. Samples represent timemore » points from hydraulic tests performed on the perched aquifer using the three wells. The isotope analyses showed that the perched water had δ 2H and δ 18O ratios consistent with the regional meteoric water line, indicating that local precipitation events at the Hanford site likely account for recharge of the perched water aquifer. Data from the isotope analysis can be used along with pumping and recovery data to help understand the perched water dynamics related to aquifer size and hydraulic control of the aquifer in the future.« less

  18. 78 FR 36760 - Petition for Waiver and Notice of Granting the Application for Interim Waiver of BSH Home...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-19

    ... collected water into either a drain line or an in-unit container, these products do not use an exhaust port... conventional vented clothes dryer cannot be used, such as high-rise apartments and other buildings where... those dwellers of high-rise apartments and others who in many cases have no way to vent to the outside...

  19. From Chicken Breath to the Killer Lakes of Cameroon: Uniting Seven Interesting Phenomena with a Single Chemical Underpinning.

    ERIC Educational Resources Information Center

    DeLorenzo, Ron

    2001-01-01

    Recommends integrating different applications to serve the need for students to know the relevancy of the course of their future. Uses different and unrelated phenomena to teach equilibria. Introduces six phenomena; (1) Killer Lakes of Cameroon, (2) Chicken Breath, (3) The Permian Ocean, (4) Snow Line, (5) Hard-Water Boiler Scale, and (6)…

  20. Groundwater studies in arid areas in Egypt using LANDSAT satellite images

    NASA Technical Reports Server (NTRS)

    Elshazly, E. M.; Abdelhady, M. A.; Elshazly, M. M.

    1977-01-01

    Various features are interpreted which have strong bearing on groundwater in the arid environment. These include the nature of geological and lithologic units, structural lineaments, present and old drainage systems, distribution and form of water pools, geomorphologic units, weathering surfaces and other weathering phenomena, desert soils, sand dunes and dune sand accumulations, growths of natural vegetation and agriculture, and salt crusts and other expressions of salinization. There are many impressive examples which illustrate the significance of satellite image interpretation on the regional conditions of groundwater which could be traced and interconnected over several tens or even several hundreds of kilometers. This is especially true in the northern Western Desert of Egypt where ground water issuing from deep strata comes to the surface along ENE-WSW and ESE-WNW fault lines and fracture systems. Another striking example is illustrated by the occurrence of fresh to brackish groundwater on the Mediterranean Sea Coastal Zone of the Western Desert where the groundwater is found in the form of lenses floating on the saline sea water.

  1. Testing the generalized complementary relationship of evaporation with continental-scale long-term water-balance data

    NASA Astrophysics Data System (ADS)

    Szilagyi, Jozsef; Crago, Richard; Qualls, Russell J.

    2016-09-01

    The original and revised versions of the generalized complementary relationship (GCR) of evaporation (ET) were tested with six-digit Hydrologic Unit Code (HUC6) level long-term (1981-2010) water-balance data (sample size of 334). The two versions of the GCR were calibrated with Parameter-Elevation Regressions on Independent Slopes Model (PRISM) mean annual precipitation (P) data and validated against water-balance ET (ETwb) as the difference of mean annual HUC6-averaged P and United States Geological Survey HUC6 runoff (Q) rates. The original GCR overestimates P in about 18% of the PRISM grid points covering the contiguous United States in contrast with 12% of the revised version. With HUC6-averaged data the original version has a bias of -25 mm yr-1 vs the revised version's -17 mm yr-1, and it tends to more significantly underestimate ETwb at high values than the revised one (slope of the best fit line is 0.78 vs 0.91). At the same time it slightly outperforms the revised version in terms of the linear correlation coefficient (0.94 vs 0.93) and the root-mean-square error (90 vs 92 mm yr-1).

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hunter, S. R.; Daniel, A.

    The purpose of the Cooperative Research and Development Agreement (CRADA) between UT-Battelle, LLC and Southwire Company was to jointly develop a low cost, commercially viable, water-repellant anti-icing coating system for high voltage transmission lines. Icing of power lines and other structures caused by freezing rain events occurs annually in the United States, and leads to severe and prolonged power outages. These outages cause untold economic and personal distress for many American families and businesses. Researchers at the Department of Energy?s Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee have previously developed a set of superhydrophobic coatings with remarkable anti-icingmore » properties that could potentially be sprayed or painted onto high-tension power lines and pylons. These coatings drastically reduce ice accumulation on these structures during freezing rain events. The project involved obtaining technical input, supplies and test high voltage cables from Southwire, along with the joint development of anti-icing coating techniques, which would result in a commercial license agreement between Southwire and ORNL, and potentially other companies requiring water repellent anti-icing coatings.« less

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hunter, Scott Robert

    The purpose of the Cooperative Research and Development Agreement (CRADA) between UT-Battelle, LLC and Southwire Company was to jointly develop a low cost, commercially viable, water-repellant anti-icing coating system for high voltage transmission lines. Icing of power lines and other structures caused by freezing rain events occurs annually in the United States, and leads to severe and prolonged power outages. These outages cause untold economic and personal distress for many American families and businesses. Researchers at the Department of Energy s Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee have previously developed a set of superhydrophobic coatings with remarkablemore » anti-icing properties that could potentially be sprayed or painted onto high-tension power lines and pylons. These coatings drastically reduce ice accumulation on these structures during freezing rain events. The project involved obtaining technical input, supplies and test high voltage cables from Southwire, along with the joint development of anti-icing coating techniques, which would result in a commercial license agreement between Southwire and ORNL, and potentially other companies requiring water repellent anti-icing coatings.« less

  4. The wister mud pot lineament: Southeastward extension or abandoned strand of the San Andreas fault?

    USGS Publications Warehouse

    Lynch, D.K.; Hudnut, K.W.

    2008-01-01

    We present the results of a survey of mud pots in the Wister Unit of the Imperial Wildlife Area. Thirty-three mud pots, pot clusters, or related geothermal vents (hundreds of pots in all) were identified, and most were found to cluster along a northwest-trending line that is more or less coincident with the postulated Sand Hills fault. An extrapolation of the trace of the San Andreas fault southeastward from its accepted terminus north of Bombay Beach very nearly coincides with the mud pot lineament and may represent a surface manifestation of the San Andreas fault southeast of the Salton Sea. Additionally, a recent survey of vents near Mullet Island in the Salton Sea revealed eight areas along a northwest-striking line where gas was bubbling up through the water and in two cases hot mud and water were being violently ejected.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Collins, Benjamin S.

    The Futility package contains the following: 1) Definition of the size of integers and real numbers; 2) A generic Unit test harness; 3) Definitions for some basic extensions to the Fortran language: arbitrary length strings, a parameter list construct, exception handlers, command line processor, timers; 4) Geometry definitions: point, line, plane, box, cylinder, polyhedron; 5) File wrapper functions: standard Fortran input/output files, Fortran binary files, HDF5 files; 6) Parallel wrapper functions: MPI, and Open MP abstraction layers, partitioning algorithms; 7) Math utilities: BLAS, Matrix and Vector definitions, Linear Solver methods and wrappers for other TPLs (PETSC, MKL, etc), preconditioner classes;more » 8) Misc: random number generator, water saturation properties, sorting algorithms.« less

  6. Analytical results from an environmental investigation of six sites on Kirtland Air Force Base, New Mexico, 1993-94

    USGS Publications Warehouse

    Wilcox, Ralph

    1995-01-01

    The six sites investigated include silver recovery units; a buried caustic drain line; a neutralization pit; an evaporation/infiltration pond; the Manzano fire training area; and a waste oil underground storage tank. Environmental samples of soil, pond sediment, soil gas, and water and gas in floor drains were collected and analyzed. Field quality-control samples were also collected and analyzed in association with the environmental samples. The six sites were investigated because past or current activities could have resulted in contamination of soil, pond sediment, or water and sediment in drains.

  7. A new investigation on the water isotopes in the Badain Jaran Desert, China, for inferring water origination

    NASA Astrophysics Data System (ADS)

    Wu, X.; Wang, Y.; Wang, X. S.; Hu, B.

    2017-12-01

    Stable isotope δ2H, δ18O and d-excess values of water have previously been used to study the hydraulic connection of groundwater between the surrounding areas such as Heihe River Basin, Qilian Mountain and the Badain Jaran desert (BJD), China. We choose to focus on the effects of strong evaporation on the isotopic characteristics of water in the desert to better understand the origin of water in the BJD. A series of evaporation experiments were conducted in the desert to examine how it may change during evaporation and infiltration under local environmental conditions. Evaporation from open water was monitored in two experiments using local groundwater and lake water, respectively. And evaporation of soil water was observed in three pits which were excavated to different depths below a flat ground surface to install the evaporation-infiltration systems. Water samples were also collected from lakes, a spring and local unconfined aquifer for analyses of stable hydrogen and oxygen isotope ratios, and d-excess values in the BJD. The results show that water isotope contents became progressively enriched along an evaporation line, and the d-excess values decreased with the evaporation. The strong relationship of d-excess and δ18O values was observed from both the experiments and the water samples of groundwater and lakes, which is considered to be a signature of strong evaporation. Also, all the values of groundwater and lake water samples fall along with the evaporation line established through the evaporation experiments, indicating that lakes and groundwater in the study area have evolved from meteoric precipitation under modern or similar to modern climatic conditions. Analysis of a few previously published d-excess and δ18O values of groundwater from the BJD, Lake Eyre Basin, Australia, and Jabal Hafit mountain, United Arab Emirates reveals strong relationships between the two, suggesting similar recharge processes as observed in the BJD. This study demonstrated that the characteristic water isotopic patterns resulting from evaporation could be utilized to help resolve ambiguities in the interpretation of water isotope data in terms of recharge sources, especially, in the arid regions, such as the central Australia and the deserts of United Arab Emirates.

  8. mizuRoute version 1: A river network routing tool for a continental domain water resources applications

    USGS Publications Warehouse

    Mizukami, Naoki; Clark, Martyn P.; Sampson, Kevin; Nijssen, Bart; Mao, Yixin; McMillan, Hilary; Viger, Roland; Markstrom, Steven; Hay, Lauren E.; Woods, Ross; Arnold, Jeffrey R.; Brekke, Levi D.

    2016-01-01

    This paper describes the first version of a stand-alone runoff routing tool, mizuRoute. The mizuRoute tool post-processes runoff outputs from any distributed hydrologic model or land surface model to produce spatially distributed streamflow at various spatial scales from headwater basins to continental-wide river systems. The tool can utilize both traditional grid-based river network and vector-based river network data. Both types of river network include river segment lines and the associated drainage basin polygons, but the vector-based river network can represent finer-scale river lines than the grid-based network. Streamflow estimates at any desired location in the river network can be easily extracted from the output of mizuRoute. The routing process is simulated as two separate steps. First, hillslope routing is performed with a gamma-distribution-based unit-hydrograph to transport runoff from a hillslope to a catchment outlet. The second step is river channel routing, which is performed with one of two routing scheme options: (1) a kinematic wave tracking (KWT) routing procedure; and (2) an impulse response function – unit-hydrograph (IRF-UH) routing procedure. The mizuRoute tool also includes scripts (python, NetCDF operators) to pre-process spatial river network data. This paper demonstrates mizuRoute's capabilities to produce spatially distributed streamflow simulations based on river networks from the United States Geological Survey (USGS) Geospatial Fabric (GF) data set in which over 54 000 river segments and their contributing areas are mapped across the contiguous United States (CONUS). A brief analysis of model parameter sensitivity is also provided. The mizuRoute tool can assist model-based water resources assessments including studies of the impacts of climate change on streamflow.

  9. Cycle chemistry monitoring system as means of improving the reliability of the equipment at the power plants

    NASA Astrophysics Data System (ADS)

    Yegoshina, O. V.; Voronov, V. N.; Yarovoy, V. O.; Bolshakova, N. A.

    2017-11-01

    There are many problems in domestic energy at the present that require urgent solutions in the near future. One of these problems - the aging of the main and auxiliary equipment. Wear of equipment is the cause of decrease reliability and efficiency of power plants. Reliability of the equipment are associated with the introduction of cycle chemistry monitoring system. The most damageable equipment’s are boilers (52.2 %), turbines (12.6 %) and heating systems (12.3 %) according to the review of failure rate on the power plants. The most part of the damageability of the boiler is heated surfaces (73.2 %). According to the Russian technical requirements, the monitoring systems are responsible to reduce damageability the boiler heating surfaces and to increase the reliability of the equipment. All power units capacity of over 50 MW are equipped with cycle chemistry monitoring systems in order to maintain water chemistry within operating limits. The main idea of cycle chemistry monitoring systems is to improve water chemistry at power plants. According to the guidelines, cycle chemistry monitoring systems of a single unit depends on its type (drum or once-through boiler) and consists of: 20…50 parameters of on-line chemical analyzers; 20…30 «grab» sample analyses (daily) and about 15…20 on-line monitored operating parameters. The operator of modern power plant uses with many data at different points of steam/water cycle. Operators do not can estimate quality of the cycle chemistry due to the large volume of daily and every shift information and dispersion of data, lack of systematization. In this paper, an algorithm for calculating the quality index developed for improving control the water chemistry of the condensate, feed water and prevent scaling and corrosion in the steam/water cycle.

  10. United States Frigate Constellation: Monitoring of Water at Constellation Pier, Baltimore Harbor, for the Presence of Marine Wood-Destroyers--First Year of Observations, from April 1978 to May 1979.

    DTIC Science & Technology

    1980-09-30

    10- by 20-cm southern pine sapwood panels spaced approximately 1.5 m (5 ft) apart (center to center) on a supporting line; the lowest panel is...level [91. Such a climatic phenomenon could occur for the Chesapeake Bay area . Fouling Organisms The yearly settlement of epifaunal organisms at

  11. Flow unit modeling and fine-scale predicted permeability validation in Atokan sandstones: Norcan East Kansas

    USGS Publications Warehouse

    Bhattacharya, S.; Byrnes, A.P.; Watney, W.L.; Doveton, J.H.

    2008-01-01

    Characterizing the reservoir interval into flow units is an effective way to subdivide the net-pay zone into layers for reservoir simulation. Commonly used flow unit identification techniques require a reliable estimate of permeability in the net pay on a foot-by-foot basis. Most of the wells do not have cores, and the literature is replete with different kinds of correlations, transforms, and prediction methods for profiling permeability in pay. However, for robust flow unit determination, predicted permeability at noncored wells requires validation and, if necessary, refinement. This study outlines the use o f a spreadsheet-based permeability validation technique to characterize flow units in wells from the Norcan East field, Clark County, Kansas, that produce from Atokan aged fine- to very fine-grained quartzarenite sandstones interpreted to have been deposited in brackish-water, tidally dominated restricted tidal-flat, tidal-channel, tidal-bar, and estuary bay environments within a small incised-valley-fill system. The methodology outlined enables the identification of fieldwide free-water level and validates and refines predicted permeability at 0.5-ft (0.15-m) intervals by iteratively reconciling differences in water saturation calculated from wire-line log and a capillary-pressure formulation that models fine- to very fine-grained sandstone with diagenetic clay and silt or shale laminae. The effectiveness of this methodology was confirmed by successfully matching primary and secondary production histories using a flow unit-based reservoir model of the Norcan East field without permeability modifications. The methodologies discussed should prove useful for robust flow unit characterization of different kinds of reservoirs. Copyright ?? 2008. The American Association of Petroleum Geologists. All rights reserved.

  12. Helicopter electromagnetic and magnetic geophysical survey data, portions of the North Platte and South Platte Natural Resources Districts, western Nebraska, May 2009

    USGS Publications Warehouse

    Smith, B.D.; Abraham, J.D.; Cannia, J.C.; Minsley, B.J.; Deszcz-Pan, M.; Ball, L.B.

    2010-01-01

    This report is a release of digital data from a helicopter electromagnetic and magnetic survey that was conducted during June 2009 in areas of western Nebraska as part of a joint hydrologic study by the North Platte Natural Resource District (NRD), South Platte NRD, and U.S. Geological Survey (USGS). Flight lines for the survey totaled 937 line kilometers (582 line miles). The objective of the contracted survey, conducted by Fugro Airborne, Ltd., is to improve the understanding of the relation between surface-water and groundwater systems critical to developing groundwater models used in management programs for water resources. A unique aspect of the survey is the flight line layout. One set of flight lines was flown in a zig-zag pattern extending along the length of the previously collected airborne data. The success of this survey design depended on a well-understood regional hydrogeologic framework and model developed by the Cooperative Hydrologic Study of the Platte River Basin and the airborne geophysical data collected in 2008. Resistivity variations along lines could be related to this framework. In addition to these lines, more traditional surveys consisting of parallel flight lines, separated by about 400 meters were carried out for three blocks in the North Platte NRD, the South Platte NRD and in the area of Crescent Lakes. These surveys helped to establish the spatial variations of the resistivity of hydrostratigraphic units. An additional survey was flown over the Crescent Lake area. The objective of this survey, funded by the USGS Office of Groundwater, was to map shallow hydrogeologic features of the southwestern part of the Sand Hills that contain a mix of fresh to saline lakes.

  13. Efficacy of a Low Dose of Hydrogen Peroxide (Peroxy Ag⁺) for Continuous Treatment of Dental Unit Water Lines: Challenge Test with Legionella pneumophila Serogroup 1 in a Simulated Dental Unit Waterline.

    PubMed

    Ditommaso, Savina; Giacomuzzi, Monica; Ricciardi, Elisa; Zotti, Carla M

    2016-07-22

    This study was designed to examine the in vitro bactericidal activity of hydrogen peroxide against Legionella. We tested hydrogen peroxide (Peroxy Ag⁺) at 600 ppm to evaluate Legionella survival in a simulated dental treatment water system equipped with Water Hygienization Equipment (W.H.E.) device that was artificially contaminated. When Legionella pneumophila serogroup (sg) 1 was exposed to Peroxy Ag⁺ for 60 min we obtained a two decimal log reduction. High antimicrobial efficacy was obtained with extended periods of exposure: four decimal log reduction at 75 min and five decimal log reduction at 15 h of exposure. Involving a simulation device (Peroxy Ag⁺ is flushed into the simulation dental unit waterlines (DUWL)) we obtained an average reduction of 85% of Legionella load. The product is effective in reducing the number of Legionella cells after 75 min of contact time (99.997%) in the simulator device under test conditions. The Peroxy Ag⁺ treatment is safe for continuous use in the dental water supply system (i.e., it is safe for patient contact), so it could be used as a preventive option, and it may be useful in long-term treatments, alone or coupled with a daily or periodic shock treatment.

  14. Measure Guideline: Transitioning to a Tankless Water Heater

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brozyna, K.; Rapport, A.

    2012-09-01

    This Measure Guideline provides information to help residential builders and retrofitters with the design, specification, selection, implementation, installation, and maintenance issues of transitioning from tank-type water heaters to tankless water heaters. The report compares the differences between tankless and tank-type water heaters, highlighting the energy savings that can be realized by adopting tankless water heaters over tank-type water heaters. Selection criteria and risks discussed include unit sizing and location, water distribution system, plumbing line length and diameter, water quality, electrical backup, and code issues. Cost and performance data are provided for various types of tankless and tank-type water heaters, bothmore » natural gas fired and electric. Also considered are interactions between the tankless water heater and other functional elements of a house, such as cold water supply and low-flow devices. Operating costs and energy use of water distribution systems for single- and two-story houses are provided, along with discussion of the various types of distribution systems that can be used with tankless water heaters. Finally, details to prepare for proper installation of a tankless water heater are described.« less

  15. Severe Accident Sequence Analysis Program: Anticipated transient without scram simulations for Browns Ferry Nuclear Plant Unit 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dallman, R J; Gottula, R C; Holcomb, E E

    1987-05-01

    An analysis of five anticipated transients without scram (ATWS) was conducted at the Idaho National Engineering Laboratory (INEL). The five detailed deterministic simulations of postulated ATWS sequences were initiated from a main steamline isolation valve (MSIV) closure. The subject of the analysis was the Browns Ferry Nuclear Plant Unit 1, a boiling water reactor (BWR) of the BWR/4 product line with a Mark I containment. The simulations yielded insights to the possible consequences resulting from a MSIV closure ATWS. An evaluation of the effects of plant safety systems and operator actions on accident progression and mitigation is presented.

  16. Direct current power delivery system and method

    DOEpatents

    Zhang, Di; Garces, Luis Jose; Dai, Jian; Lai, Rixin

    2016-09-06

    A power transmission system includes a first unit for carrying out the steps of receiving high voltage direct current (HVDC) power from an HVDC power line, generating an alternating current (AC) component indicative of a status of the first unit, and adding the AC component to the HVDC power line. Further, the power transmission system includes a second unit for carrying out the steps of generating a direct current (DC) voltage to transfer the HVDC power on the HVDC power line, wherein the HVDC power line is coupled between the first unit and the second unit, detecting a presence or an absence of the added AC component in the HVDC power line, and determining the status of the first unit based on the added AC component.

  17. 30 CFR 250.1156 - What steps must I take to receive approval to produce within 500 feet of a unit or lease line?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... produce within 500 feet of a unit or lease line? 250.1156 Section 250.1156 Mineral Resources MINERALS... I take to receive approval to produce within 500 feet of a unit or lease line? (a) You must obtain... any portion of the completed interval less than 500 feet from a unit or lease line. Submit to MMS the...

  18. Final Environmental Statement. Continental United States Over-the- Horizon Backscatter Radar System

    DTIC Science & Technology

    1975-01-01

    plants will be provided only for the operational radar system. When operating they will emit diesel exhaust fumes into the atmosphere. g. Noise...Pollution. Noise will be generated when the standby power plants are used. h. Foliage and Soil. The clearing of trees and shrubs in the...building, a 12 megawatt standby power plant , a gate house, transmit antennas, connection to commercial power lines, a paved access road, a well water

  19. Modular 3D-Printed Soil Gas Probes

    NASA Astrophysics Data System (ADS)

    Good, S. P.; Selker, J. S.; Al-Qqaili, F.; Lopez, M.; Kahel, L.

    2016-12-01

    ABSTRACT: Extraction of soil gas is required for a variety of applications in earth sciences and environmental engineering. However, commercially available probes can be costly and are typically limited to a single depth. Here, we present the open-source design and lab testing of a soil gas probe with modular capabilities that allow for the vertical stacking of gas extraction points at different depths in the soil column. The probe modules consist of a 3D printed spacer unit and hydrophobic gas permeable membrane made of high density Polyethylene with pore sizes 20-40 microns. Each of the modular spacer units contain both a gas extraction line and gas input line for the dilution of soil gases if needed. These 2-inch diameter probes can be installed in the field quickly with a hand auger and returned to at any frequency to extract soil gas from desired soil depths. The probes are tested through extraction of soil pore water vapors with distinct stable isotope ratios.

  20. 77 FR 59391 - Delta Air Lines, Inc., Continental Airlines, Inc., JetBlue Airways Corporation, United Air Lines...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-27

    ... lawfulness of the rates charged by the Respondent for transportation of jet or aviation turbine fuel on its..., Inc., Continental Airlines, Inc., JetBlue Airways Corporation, United Air Lines, Inc., US Airways, Inc... Airlines, Inc., JetBlue Airways Corporation, United Air Lines, Inc., and US Airways, Inc. (collectively...

  1. 46 CFR 42.13-30 - Lines to be used with the load line mark.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) The following load lines shall be used: (1) The summer load line indicated by the upper edge of the... T. (5) The fresh water load line in summer indicated by the upper edge of a line marked F. The fresh water load line in summer is marked abaft the vertical line. The difference between the fresh water load...

  2. 46 CFR 42.13-30 - Lines to be used with the load line mark.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) The following load lines shall be used: (1) The summer load line indicated by the upper edge of the... T. (5) The fresh water load line in summer indicated by the upper edge of a line marked F. The fresh water load line in summer is marked abaft the vertical line. The difference between the fresh water load...

  3. Uncertainties in water chemistry in disks: An application to TW Hydrae

    NASA Astrophysics Data System (ADS)

    Kamp, I.; Thi, W.-F.; Meeus, G.; Woitke, P.; Pinte, C.; Meijerink, R.; Spaans, M.; Pascucci, I.; Aresu, G.; Dent, W. R. F.

    2013-11-01

    Context. This paper discusses the sensitivity of water lines to chemical processes and radiative transfer for the protoplanetary disk around TW Hya. The study focuses on the Herschel spectral range in the context of new line detections with the PACS instrument from the Gas in Protoplanetary Systems project (GASPS). Aims: The paper presents an overview of the chemistry in the main water reservoirs in the disk around TW Hya. It discusses the limitations in the interpretation of observed water line fluxes. Methods: We use a previously published thermo-chemical Protoplanetary Disk Model (ProDiMo) of the disk around TW Hya and study a range of chemical modeling uncertainties: metallicity, C/O ratio, and reaction pathways and rates leading to the formation of water. We provide results for the simplified assumption of Tgas = Tdust to quantify uncertainties arising for the complex heating/cooling processes of the gas and elaborate on limitations due to water line radiative transfer. Results: We report new line detections of p-H2O (322-211) at 89.99 μm and CO J = 18-17 at 144.78 μm for the disk around TW Hya. Disk modeling shows that the far-IR fine structure lines ([O i], [C ii]) and molecular submm lines are very robust to uncertainties in the chemistry, while the water line fluxes can change by factors of a few. The water lines are optically thick, sub-thermally excited and can couple to the background continuum radiation field. The low-excitation water lines are also sensitive to uncertainties in the collision rates, e.g. with neutral hydrogen. The gas temperature plays an important role for the [O i] fine structure line fluxes, the water line fluxes originating from the inner disk as well as the high excitation CO, CH+ and OH lines. Conclusions: Due to their sensitivity on chemical input data and radiative transfer, water lines have to be used cautiously for understanding details of the disk structure. Water lines covering a wide range of excitation energies provide access to the various gas phase water reservoirs (inside and outside the snow line) in protoplanetary disks and thus provide important information on where gas-phase water is potentially located. Experimental and/or theoretical collision rates for H2O with atomic hydrogen are needed to diminish uncertainties from water line radiative transfer. Herschel is an ESA space observatory with science instruments provided by European-led Principal Investigator consortia and with important participation from NASA.Appendices are available in electronic form at http://www.aanda.org

  4. Quality in Higher Education: Perspectives from Front-Line Faculty in the United States

    ERIC Educational Resources Information Center

    Hall, Molly Reas

    2015-01-01

    The purpose of this study was to explore perceptions of front-line faculty members in the United States related to quality and quality management in higher education. The study's three research questions were: (1) How do front-line faculty members in the United States define quality in higher education? (2) How do front-line faculty members in the…

  5. Digital communication system

    NASA Technical Reports Server (NTRS)

    Monford, L. G., Jr. (Inventor)

    1974-01-01

    A digital communication system is reported for parallel operation of 16 or more transceiver units with the use of only four interconnecting wires. A remote synchronization circuit produces unit address control words sequentially in data frames of 16 words. Means are provided in each transceiver unit to decode calling signals and to transmit calling and data signals. The transceivers communicate with each other over one data line. The synchronization unit communicates the address control information to the transceiver units over an address line and further provides the timing information over a clock line. A reference voltage level or ground line completes the interconnecting four wire hookup.

  6. Development of a wavelength stabilized seed laser system for an airborne water vapour lidar experiment

    NASA Astrophysics Data System (ADS)

    Schwarzer, H.; Börner, A.; Fix, A.; Günther, B.; Hübers, H.-W.; Raugust, M.; Schrandt, F.; Wirth, M.

    2007-09-01

    At the German Aerospace Center an airborne multi-wavelength differential absorption LIDAR for the measurement of atmospheric water vapour is currently under development. This instrument will enable the retrieval of the complete humidity profile from the surface up to the lowermost stratosphere with high vertical and horizontal resolution at a systematic error below 5%. The LIDAR will work in the wavelength region around 935 nm at three different water vapour absorption lines and one reference wavelength. A major sub-system of this instrument is a highly frequency stabilized seed laser system for the optical parametrical oscillators which generate the narrowband high energy light pulses. The development of the seed laser system includes the control software, the electronic control unit and the opto-mechanical layout. The seed lasers are Peltier-cooled distributed feedback laser diodes with bandwidths of about 30 MHz, each one operating for 200 μs before switching to the next one. The required frequency stability is +/- 30 MHz ≅ +/- 10 -4 nm under the rough environmental conditions aboard an aircraft. It is achieved by locking the laser wavelength to a water vapour absorption line. The paper describes the opto-mechanical layout of the seed laser system, the stabilization procedure and the results obtained with this equipment.

  7. Evidence for water vapor in Titan's atmosphere from ISO/SWS data

    NASA Astrophysics Data System (ADS)

    Coustenis, A.; Salama, A.; Lellouch, E.; Encrenaz, Th.; Bjoraker, G. L.; Samuelson, R. E.; de Graauw, Th.; Feuchtgruber, H.; Kessler, M. F.

    1998-08-01

    The infrared spectrum of Titan around 40 mu m was recorded in the grating mode of the Short Wavelength Spectrometer (SWS) of ISO, with a resolving power of about 1900. Two emission features appear at 43.9 and 39.4 mu m, where pure rotational water lines are expected. Line strengths are about 8 times the 1sigma statistical noise level. The H_2O vertical profile for water suggested by the photochemical model of Lara et al. (1996), rescaled by a factor of about 0.4(+0.3}_{-0.2) , is compatible with the data. The associated water mole fraction is about 8(+6}_{-4) x 10(-9) at an altitude of 400 km (column density of 2.6(+1.9}_{-1.6) x 10(14) mol cm(-2) above the surface). The inferred water influx at 700 km in Titan's atmosphere is in the range (0.8-2.8) x 10(6) mol cm(-2) s(-1) . Based on observations with ISO, an ESA project with instruments funded by ESA Member States (especially the PI countries: France, Germany, the Netherlands and the United Kingdom) with the participation of NASA and ISAS. The SWS instrument (P.I. Th. de Graauw) is a joint project of the SRON and the MPE. RES would like to thank D. Hamilton for illuminating discussions regarding dust transport in the Saturn System.

  8. Architecture-Based Unit Testing of the Flight Software Product Line

    NASA Technical Reports Server (NTRS)

    Ganesan, Dharmalingam; Lindvall, Mikael; McComas, David; Bartholomew, Maureen; Slegel, Steve; Medina, Barbara

    2010-01-01

    This paper presents an analysis of the unit testing approach developed and used by the Core Flight Software (CFS) product line team at the NASA GSFC. The goal of the analysis is to understand, review, and reconunend strategies for improving the existing unit testing infrastructure as well as to capture lessons learned and best practices that can be used by other product line teams for their unit testing. The CFS unit testing framework is designed and implemented as a set of variation points, and thus testing support is built into the product line architecture. The analysis found that the CFS unit testing approach has many practical and good solutions that are worth considering when deciding how to design the testing architecture for a product line, which are documented in this paper along with some suggested innprovennents.

  9. Water quality in turkey farms in Khemisset (Morocco) and potential risk factors.

    PubMed

    El Allaoui, A; Rhazi Filali, F; Derouich, A

    2016-12-01

    The objectives of this study were to assess the microbiological and physical/chemical quality of water in broiler turkey farms in the province of Khemisset (north-western Morocco) and, based on a questionnaire, to ascertain potential risk factors for contamination of drinking water with faecal coliforms. A total of 80 samples were collected and analysed in 20 farms (four from each farm). At the main inlet to the water line at the entrance to each turkey house, 100% of the samples were of unacceptable quality in terms of faecal coliforms, Escherichia coli, faecal streptococci, sulphitereducing anaerobes and enterococci. A significant reduction in microbiological contamination of the water line (p < 0.05) was observed on Day 60. While more than 90% of the samples were of satisfactory quality in terms of pH, nitrites, conductivity, nitrates and iron, only 35% were satisfactory in terms of total hardness and only 20% met quality standards for ammonium content. The factors affecting levels of contamination with faecal coliforms were water chlorination (p = 0.065; odds ratio = 14; 90% confidence interval [CI] = 1.14-71), cleaning and disinfection (p = 0.028; odds ratio = 14; 95% CI = 1.25-156.6) and antibiotic treatment (p = 0.001; odds ratio = 6; 95% CI = 2.1-35.2). To improve water quality in poultry farms, farmers are advised to protect wells from contamination and to install water purification units (pre-oxidation, coagulation, flocculation, disinfection). In addition, turkey houses and rearing equipment should be rigorously cleaned and disinfected between each batch of birds. © OIE (World Organisation for Animal Health), 2016.

  10. Photographic copy of historic photograph, by Corps of Engineers, U.S. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photographic copy of historic photograph, by Corps of Engineers, U.S. Army, September 4, 1940 (original in possession of Corps of Engineers, U.S. Army, Pittsburgh District, Engineering Division files) Unit 4, view of water line construction upstream at Walnut Street Bridgeupstream from point stadium - Johnstown Local Flood Protection Project, Beginning on Conemaugh River approx 3.8 miles downstream from confluence of Little Conemaugh & Stony Creek Rivers at Johnstown, Johnstown, Cambria County, PA

  11. Nitric Oxide Measurement Study. Volume II. Probe Methods,

    DTIC Science & Technology

    1980-05-01

    case of the Task I study, it should be pointed out that at lower gas temperatures where much of the study was performed, the mass flow through the...third body as pointed out by Matthews, et al. (1977) but also dependent on the viscosity of the sampled gas for standard commercial units (Folsom and...substantially above the dew point (based on the maximum pressure in the sampling system and the initial water concentration) or (2) sample line and

  12. Interim reliability evaluation program, Browns Ferry 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mays, S.E.; Poloski, J.P.; Sullivan, W.H.

    1981-01-01

    Probabilistic risk analysis techniques, i.e., event tree and fault tree analysis, were utilized to provide a risk assessment of the Browns Ferry Nuclear Plant Unit 1. Browns Ferry 1 is a General Electric boiling water reactor of the BWR 4 product line with a Mark 1 (drywell and torus) containment. Within the guidelines of the IREP Procedure and Schedule Guide, dominant accident sequences that contribute to public health and safety risks were identified and grouped according to release categories.

  13. METHOD AND APPARATUS FOR THE DETECTION OF LEAKS IN PIPE LINES

    DOEpatents

    Jefferson, S.; Cameron, J.F.

    1961-11-28

    A method is described for detecting leaks in pipe lines carrying fluid. The steps include the following: injecting a radioactive solution into a fluid flowing in the line; flushing the line clear of the radioactive solution; introducing a detector-recorder unit, comprising a radioactivity radiation detector and a recorder which records the detector signal over a time period at a substantially constant speed, into the line in association with a go-devil capable of propelling the detector-recorder unit through the line in the direction of the fluid flow at a substantia1ly constant velocity; placing a series of sources of radioactivity at predetermined distances along the downstream part of the line to make a characteristic signal on the recorder record at intervals corresponding to the location of said sources; recovering the detector-recorder unit at a downstream point along the line; transcribing the recorder record of any radioactivity detected during the travel of the detector- recorder unit in terms of distance along the line. (AEC)

  14. Estimates of natural ground-water discharge and characterization of water quality in Dry Valley, Washoe County, West-Central Nevada, 2002-2003

    USGS Publications Warehouse

    Berger, David L.; Maurer, Douglas K.; Lopes, Thomas J.; Halford, Keith J.

    2004-01-01

    The Dry Valley Hydrographic Area is being considered as a potential source area for additional water supplies for the Reno-Sparks area, which is about 25 miles south of Dry Valley. Current estimates of annual ground-water recharge to Dry Valley have a considerable range. In undeveloped valleys, such as Dry Valley, long-term ground-water discharge can be assumed the same as long-term ground-water recharge. Because estimating ground-water discharge has more certainty than estimating ground-water recharge from precipitation, the U.S. Geological Survey, in cooperation with Washoe County, began a three-year study to re-evaluate the ground-water resources by estimating natural ground-water discharge and characterize ground-water quality in Dry Valley. In Dry Valley, natural ground-water discharge occurs as subsurface outflow and by ground-water evapotranspiration. The amount of subsurface outflow from the upper part of Dry Valley to Winnemucca and Honey Lake Valleys likely is small. Subsurface outflow from Dry Valley westward to Long Valley, California was estimated using Darcy's Law. Analysis of two aquifer tests show the transmissivity of poorly sorted sediments near the western side of Dry Valley is 1,200 to 1,500 square feet per day. The width of unconsolidated sediments is about 4,000 feet between exposures of tuffaceous deposits along the State line, and decreases to about 1,500 feet (0.5 mile) west of the State line. The hydraulic gradient east and west of the State line ranges from 0.003 to 0.005 foot per foot. Using these values, subsurface outflow to Long Valley is estimated to be 50 to 250 acre-feet per year. Areas of ground-water evapotranspiration were field mapped and partitioned into zones of plant cover using relations derived from Landsat imagery acquired July 8, 2002. Evapotranspiration rates for each plant-cover zone were multiplied by the corresponding area and summed to estimate annual ground-water evapotranspiration. About 640 to 790 acre-feet per year of ground water is lost to evapotranspiration in Dry Valley. Combining subsurface-outflow estimates with ground-water evapotranspiration estimates, total natural ground-water discharge from Dry Valley ranges from a minimum of about 700 acre-feet to a maximum of about 1,000 acre-feet annually. Water quality in Dry Valley generally is good and primary drinking-water standards were not exceeded in any samples collected. The secondary standard for manganese was exceeded in three ground-water samples. One spring sample and two surface-water samples exceeded the secondary standard for pH. Dry Valley has two primary types of water chemistry that are distinguishable by cation ratios and related to the two volcanic-rock units that make up much of the surrounding mountains. In addition, two secondary types of water chemistry appear to have evolved by evaporation of the primary water types. Ground water near the State line appears to be an equal mixture of the two primary water chemistries and has as an isotopic characteristic similar to evaporated surface water.

  15. In-line photonic microcells based on the elliptical microfibers for refractive index sensors applications

    NASA Astrophysics Data System (ADS)

    Jin, Wa; Liu, Xuejing; Jin, Wei

    2017-10-01

    We report the fabrication of in-line photonic microcells (PMCs) by encapsulating tapered elliptical microfibers (MFs) inside glass tubes. The encapsulation does not change the optical property of the MF but protects the elliptical MF from external disturbance and contamination and makes the micro-laboratory robust. Such micro-laboratory can be easily integrated into standard fiber-optic circuits with low loss, making the elliptical MF-based devices more practical for real-world applications. Evanescent field sensing is realized by fabricating micro-channel on the PMC for ingress/egress of sample liquids/gas. Based on the encapsulated elliptical MF PMCs, we demonstrated RI sensitivity of 2024 nm per refractive index unit (nm/RIU) in gaseous environment and 21231 nm/RIU in water.

  16. Solar hot water system installed at Day's Lodge, Atlanta, Georgia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1980-09-01

    The solar energy hot water system installed in the Days Inns of America, Inc., Day's Lodge I-85 and Shallowford Road, NE Atlanta, Georgia is described. This system is one of eleven systems planned under this grant and was designed to provide for 81% of the total hot water demand. There are two separate systems, each serving one building of the lodge (total of 65 suites). The entire system contains only potable city water. The 1024 square feet of Grumman Sunstream Model 332 liquid flat plate collectors and the outside piping drains whenever the collector plates approach freezing or when powermore » is interrupted. Solar heated water from the two above ground cement lined steel tanks (1000 gallon tank) is drawn into the electric domestic hot water (DHW) tanks as hot water is drawn. Electric resistance units in the DHW tanks top off the solar heated water, if needed, to reach thermostat setting. Operation of this system was begun in August, 1979. The solar components were partly funded ($18,042 of $36,084 cost) by the Department of Energy.« less

  17. Determination of six microcystins and nodularin in surface and drinking waters by on-line solid phase extraction-ultra high pressure liquid chromatography tandem mass spectrometry.

    PubMed

    Beltrán, Eduardo; Ibáñez, María; Sancho, Juan Vicente; Hernández, Félix

    2012-11-30

    Microcystins and nodularin are cyclic peptides hepatotoxins produced by cyanobacterial genera (blue-green algae). Toxic cyanobacterial blooms are a worldwide problem, as reported in several countries, like China, Australia, or the United States. Therefore, it is necessary to develop sensitive and reliable analytical methodology to determine this type of toxins in water at parts per billion levels, or even lower. In this work, the potential of solid-phase extraction coupled on-line to ultra-high-pressure liquid chromatography/electrospray tandem mass spectrometry (SPE-UHPLC-MS/MS) has been investigated for the efficient quantification and confirmation of microcystins LR, RR, YR, LY, LW, LF and nodularin in surface and drinking water samples, at sub-ppb levels. The method developed involves the injection of only 1 mL of water sample into the on-line SPE-UHPLC-MS/MS system and allows the rapid determination of the compounds selected (8 min of chromatographic run), avoiding laborious sample treatment. The method was validated in surface and drinking water by means of recovery experiments at 0.25 and 1 μg L(-1). Average recoveries (n=5) ranged from 71 to 116%, with relative standard deviations (RSDs) lower than 15%. For microcystins LR, RR, YR and nodularin, a third level was also assayed (0.1 μg L(-1)) obtaining satisfactory data too. Limits of detection between 0.002 and 0.0405 μg L(-1) were estimated (0.0005 μg L(-1) for nodularin). The developed method was applied to the analysis of water samples collected in the province of Castellón (Spain). The acquisition of three MS/MS transitions for each compound allowed the unequivocal confirmation of positive samples, which was supported by the accomplishment of ion intensity ratios and retention time when compared with reference standards. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. 75 FR 38500 - Notice of Availability of Draft Environmental Impact Statement for the Proposed Folsom South of U...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-02

    ... Water Facility Alternative--Raw Water Conveyance--Grant Line Road Alignment and On- site WTP; (3) Off-site Water Facility Alternative 1--Raw Water Conveyance--Grant Line Road Alignment and White Rock WTP; (4) Off-site Water Facility Alternative 1A--Raw Water Conveyance--Grant Line Road Route Variation...

  19. Milan Army Ammunition Plant focused feasibility study for the northern industrial area soil. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Locandro, R.R.; Okusu, N.M.; Case, J.

    1995-04-01

    ICF Kaiser Engineers (ICF) and Environmental Resources Management (ERM) have been contracted by the US Army Environmental Center (USAEC) to perform a Focused Feasibility Study (FS) for contaminated soil within the northern industrial areas of Milan Army Ammunition Plant (MAAP), Tennessee. The purpose of the Focused FS is to develop and evaluate remedial alternatives such that an appropriate remedy can be selected for the site. The MAAP Remedial Investigation (RI) performed in 1989--1991 confirmed that the O-Line Ponds area, facility drainage ditches that received industrial wastewater, and manufacturing and disposal areas have been sources of groundwater contamination. One finding ofmore » the RI Report was that sufficient information was available concerning the O-Line Ponds area to proceed with a Focused FS. The O-Line Ponds area was further divided into two operable units (OUs): OU1 is the groundwater immediately downgradient of the O-Line Ponds area, and OU2 is the soil, surface water, and sediment at the O-Line Ponds area. A Proposed Plan and Record of Decision (ROD) for OU1 were finalized in 1992, which called for groundwater extraction, treatment, and reinjection of the treated water upgradient of the O-Line Ponds. The design of this system was completed in 1993, and construction of the system is currently underway. For OU2, the Proposed Plan and ROD (finalized in 1993) called for the extension of the existing multi-layered cap to cover the contaminated soil around the perimeter of the existing cap. The design of the cap extension was completed in 1994, and construction will begin in late 1994.« less

  20. 46 CFR 46.10-45 - Nonsubmergence subdivision load lines in salt water.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Nonsubmergence subdivision load lines in salt water. 46.10-45 Section 46.10-45 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) LOAD LINES SUBDIVISION LOAD LINES FOR PASSENGER VESSELS Administration § 46.10-45 Nonsubmergence subdivision load lines in salt water. (a) Passenger vessels...

  1. SMALL DIAMETER CEMENT LINING FROM STAIRWAY. United States Pipe ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    SMALL DIAMETER CEMENT LINING FROM STAIRWAY. - United States Pipe & Foundry Company Plant, Coating, Painting, Lining & Packaging Building, 2023 St. Louis Avenue at I-20/59, Bessemer, Jefferson County, AL

  2. Chlorine Disinfection of Atypical Mycobacteria Isolated from a Water Distribution System

    PubMed Central

    Le Dantec, Corinne; Duguet, Jean-Pierre; Montiel, Antoine; Dumoutier, Nadine; Dubrou, Sylvie; Vincent, Véronique

    2002-01-01

    We studied the resistance of various mycobacteria isolated from a water distribution system to chlorine. Chlorine disinfection efficiency is expressed as the coefficient of lethality (liters per minute per milligram) as follows: Mycobacterium fortuitum (0.02) > M. chelonae (0.03) > M. gordonae (0.09) > M. aurum (0.19). For a C · t value (product of the disinfectant concentration and contact time) of 60 mg · min · liter−1, frequently used in water treatment lines, chlorine disinfection inactivates over 4 log units of M. gordonae and 1.5 log units of M. fortuitum or M. chelonae. C · t values determined under similar conditions show that even the most susceptible species, M. aurum and M. gordonae, are 100 and 330 times more resistant to chlorine than Escherichia coli. We also investigated the effects of different parameters (medium, pH, and temperature) on chlorine disinfection in a chlorine-resistant M. gordonae model. Our experimental results follow the Arrhenius equation, allowing the inactivation rate to be predicted at different temperatures. Our results show that M. gordonae is more resistant to chlorine in low-nutrient media, such as those encountered in water, and that an increase in temperature (from 4°C to 25°C) and a decrease in pH result in better inactivation. PMID:11872446

  3. Workplace Determinants of Endotoxin Exposure in Dental Healthcare Facilities in South Africa

    PubMed Central

    Singh, Tanusha S.; Bello, Braimoh; Mabe, Onnicah D.; Renton, Kevin; Jeebhay, Mohamed F.

    2010-01-01

    Objectives: Aerosols generated during dental procedures have been reported to contain endotoxin as a result of bacterial contamination of dental unit water lines. This study investigated the determinants of airborne endotoxin exposure in dental healthcare settings. Methods: The study population included dental personnel (n = 454) from five academic dental institutions in South Africa. Personal air samples (n = 413) in various dental jobs and water samples (n = 403) from dental handpieces and basin taps were collected. The chromogenic-1000 limulus amebocyte lysate assay was used to determine endotoxin levels. Exposure metrics were developed on the basis of individually measured exposures and average levels within each job category. Analysis of variance and multivariate linear regression models were constructed to ascertain the determinants of exposure in the dental group. Results: There was a 2-fold variation in personal airborne endotoxin from the least exposed (administration) to the most exposed (laboratory) jobs (geometric mean levels: 2.38 versus 5.63 EU m−3). Three percent of personal samples were above DECOS recommended exposure limit (50 EU m−3). In the univariate linear models, the age of the dental units explained the most variability observed in the personal air samples (R2 = 0.20, P < 0.001), followed by the season of the year (R2 = 0.11, P < 0.001). Other variables such as institution and total number of dental units per institution also explained a modest degree of variability. A multivariate model explaining the greatest variability (adjusted R2 = 0.40, P < 0.001) included: the age of institution buildings, total number of dental units per institution, ambient temperature, ambient air velocity, endotoxin levels in water, job category (staff versus students), dental unit model type and age of dental unit. Conclusions: Apart from job type, dental unit characteristics are important predictors of airborne endotoxin levels in this setting. PMID:20044586

  4. Waste to Watts and Water: Enabling Self-Contained Facilities Using Microbial Fuel Cells

    DTIC Science & Technology

    2009-03-01

    will require in future facilities is the ability to operate apart from the infrastructure net- work and line of communications (LOC) in a clean and ef...in future technologies, observes that “forecasters are im- prisoned by their times.”33 Humans tend to look at today’s crisis and project it into the...2030. In 2007 the United States Department of Energy (DOE) forecast international power demand to double by 2030.34 Today’s energy crisis is well

  5. Development of a Peduncle Belt as a Medium to Long-Term Tag Attachment Platform for Cetacean Studies

    DTIC Science & Technology

    2011-09-30

    swimmers with thin skins. Longer duration tests may be possible on animals housed in lagoons/coves with large swim areas and/or animals trained for...soft, shear- resistant padding. A small lower saddle unit is also used to protect the ventral ridge of the peduncle. The loose belt configuration was...tests showed a substantial reduction in retraction speed due to drag on the line as it is pulled through the water as opposed to on land. The

  6. Candidate Water Vapor Lines to Locate the H2O Snowline through High-dispersion Spectroscopic Observations. III. Submillimeter H2 16O and H2 18O Lines

    NASA Astrophysics Data System (ADS)

    Notsu, Shota; Nomura, Hideko; Walsh, Catherine; Honda, Mitsuhiko; Hirota, Tomoya; Akiyama, Eiji; Millar, T. J.

    2018-03-01

    In this paper, we extend the results presented in our former papers on using ortho-{{{H}}}2{}16{{O}} line profiles to constrain the location of the H2O snowline in T Tauri and Herbig Ae disks, to include submillimeter para-{{{H}}}2{}16{{O}} and ortho- and para-{{{H}}}2{}18{{O}} lines. Since the number densities of the ortho- and para-{{{H}}}2{}18{{O}} molecules are about 560 times smaller than their 16O analogs, they trace deeper into the disk than the ortho-{{{H}}}2{}16{{O}} lines (down to z = 0, i.e., the midplane). Thus these {{{H}}}2{}18{{O}} lines are potentially better probes of the position of the H2O snowline at the disk midplane, depending on the dust optical depth. The values of the Einstein A coefficients of submillimeter candidate water lines tend to be lower (typically <10‑4 s‑1) than infrared candidate water lines. Thus in the submillimeter candidate water line cases, the local intensity from the outer optically thin region in the disk is around 104 times smaller than that in the infrared candidate water line cases. Therefore, in the submillimeter lines, especially {{{H}}}2{}18{{O}} and para-{{{H}}}2{}16{{O}} lines with relatively lower upper state energies (∼a few 100 K) can also locate the position of the H2O snowline. We also investigate the possibility of future observations with ALMA to identify the position of the water snowline. There are several candidate water lines that trace the hot water gas inside the H2O snowline in ALMA Bands 5–10.

  7. Grounding line processes on the Totten Glacier

    NASA Astrophysics Data System (ADS)

    Cook, S.; Watson, C. S.; Galton-Fenzi, B.; Peters, L. E.; Coleman, R.

    2017-12-01

    The Totten Glacier has been an area of recent interest due to its large drainage basin, much of which is grounded below sea level and has a history of large scale grounding line movement. Reports that warm water reaches the sub-ice shelf cavity have led to speculation that it could be vulnerable to future grounding line retreat. Over the Antarctic summer 2016/17 an array of 6 GPS and autonomous phase-sensitive radar (ApRES) units were deployed in the grounding zone of the Totten Glacier. These instruments measure changes in ice velocity and thickness which can be used to investigate both ice dynamics across the grounding line, and the interaction between ice and ocean in the subglacial cavity. Basal melt rates calculated from the ApRES units on floating ice range from 1 to 17 m/a. These values are significantly lower than previous estimates of basal melt rate produced by ocean modelling of the subglacial cavity. Meanwhile, GPS-derived velocity and elevation on the surface of the ice show a strong tidal signal, as does the vertical strain rate within the ice derived from internal layering from the ApRES instruments. These results demonstrate the significance of the complex grounding pattern of the Totten Glacier. The presence of re-grounding points has significant implications for the dynamics of the glacier and the ocean circulation within the subglacial cavity. We discuss what can be learned from our in situ measurements, and how they can be used to improve models of the glacier's future behaviour.

  8. 46 CFR 45.37 - Salt water load lines.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Salt water load lines. 45.37 Section 45.37 Shipping... Marks § 45.37 Salt water load lines. Each vessel that operates in the salt water of the St. Lawrence... marks under § 45.77 for salt water; and (b) Be marked with the letters “FW” above the fresh water marks...

  9. 46 CFR 45.37 - Salt water load lines.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Salt water load lines. 45.37 Section 45.37 Shipping... Marks § 45.37 Salt water load lines. Each vessel that operates in the salt water of the St. Lawrence... marks under § 45.77 for salt water; and (b) Be marked with the letters “FW” above the fresh water marks...

  10. 46 CFR 45.37 - Salt water load lines.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Salt water load lines. 45.37 Section 45.37 Shipping... Marks § 45.37 Salt water load lines. Each vessel that operates in the salt water of the St. Lawrence... marks under § 45.77 for salt water; and (b) Be marked with the letters “FW” above the fresh water marks...

  11. 46 CFR 45.37 - Salt water load lines.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Salt water load lines. 45.37 Section 45.37 Shipping... Marks § 45.37 Salt water load lines. Each vessel that operates in the salt water of the St. Lawrence... marks under § 45.77 for salt water; and (b) Be marked with the letters “FW” above the fresh water marks...

  12. 46 CFR 45.37 - Salt water load lines.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Salt water load lines. 45.37 Section 45.37 Shipping... Marks § 45.37 Salt water load lines. Each vessel that operates in the salt water of the St. Lawrence... marks under § 45.77 for salt water; and (b) Be marked with the letters “FW” above the fresh water marks...

  13. Cold weather effects on Dresden Unit 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anagnostopoulos, H.

    1995-03-01

    Dresden Unit 1 is in the final stages of a decommissioning effort directed at preparing the unit to enter a SAFSTOR status. Following an extended sub-zero cold wave, about 55,000 gallons of water were discovered in the lowest elevation of the spherical reactor enclosure. Cold weather had caused the freezing and breaking of several service water lines that had not been completely isolated. Two days later, at a regularly scheduled decommissioning meeting, the event was communicated to the decommissioning team, who quickly recognized the potential for freezing of a 42 inches diameter Fuel Transfer Tube that connects the sphere tomore » the Spent Fuel Pool. The team directed that the pool gates between the adjacent Spent Fuel Pool and the Fuel Transfer Pool be installed, and a portable source of heat was installed on the Fuel Transfer Tube. It was later determined that, with the fuel pool gates removed, and with a worst case freeze break at the 502 elevation on the Fuel Transfer Tube (in the Sphere), the fuel in the Spent Fuel Pool could be uncovered to a level 3 below the top of active fuel.« less

  14. SMALL DIAMETER PRECEMENT LINING FROM CATWALK ABOVE. United States ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    SMALL DIAMETER PRE-CEMENT LINING FROM CATWALK ABOVE. - United States Pipe & Foundry Company Plant, Coating, Painting, Lining & Packaging Building, 2023 St. Louis Avenue at I-20/59, Bessemer, Jefferson County, AL

  15. 40 CFR Table 37 to Subpart Uuu of... - Requirements for Performance Tests for Bypass Lines

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Bypass Lines 37 Table 37 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION... Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 37 Table 37 to Subpart UUU of Part 63—Requirements for Performance Tests for Bypass Lines As...

  16. 40 CFR Table 37 to Subpart Uuu of... - Requirements for Performance Tests for Bypass Lines

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Bypass Lines 37 Table 37 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION... Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 37 Table 37 to Subpart UUU of Part 63—Requirements for Performance Tests for Bypass Lines As...

  17. 40 CFR Table 37 to Subpart Uuu of... - Requirements for Performance Tests for Bypass Lines

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Bypass Lines 37 Table 37 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION... Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 37 Table 37 to Subpart UUU of Part 63—Requirements for Performance Tests for Bypass Lines As...

  18. Lead in drinking water and human blood lead levels in the United States.

    PubMed

    Brown, Mary Jean; Margolis, Stephen

    2012-08-10

    Lead is a pervasive environmental contaminant. The adverse health effects of lead exposure in children and adults are well documented, and no safe blood lead threshold in children has been identified. Lead can be ingested from various sources, including lead paint and house dust contaminated by lead paint, as well as soil, drinking water, and food. The concentration of lead, total amount of lead consumed, and duration of lead exposure influence the severity of health effects. Because lead accumulates in the body, all sources of lead should be controlled or eliminated to prevent childhood lead poisoning. Beginning in the 1970s, lead concentrations in air, tap water, food, dust, and soil began to be substantially reduced, resulting in significantly reduced blood lead levels (BLLs) in children throughout the United States. However, children are still being exposed to lead, and many of these children live in housing built before the 1978 ban on lead-based residential paint. These homes might contain lead paint hazards, as well as drinking water service lines made from lead, lead solder, or plumbing materials that contain lead. Adequate corrosion control reduces the leaching of lead plumbing components or solder into drinking water. The majority of public water utilities are in compliance with the Safe Drinking Water Act Lead and Copper Rule (LCR) of 1991. However, some children are still exposed to lead in drinking water. EPA is reviewing LCR, and additional changes to the rule are expected that will further protect public health. Childhood lead poisoning prevention programs should be made aware of the results of local public water system lead monitoring measurement under LCR and consider drinking water as a potential cause of increased BLLs, especially when other sources of lead exposure are not identified.

  19. Geohydrology and ground-water resources of Philadelphia, Pennsylvania

    USGS Publications Warehouse

    Paulachok, Gary N.

    1991-01-01

    The aquifers underlying the 134.6-square-mile city of Philadelphia are divided by the Fall Line into the unconsolidated aquifers (chiefly sand and gravel) of the Coastal Plain and the consolidated-rock aquifers (chiefly schist of the Wissahickon Formation) of the Piedmont. Ground water is present under confined and unconfined conditions. The principal units of the confined-aquifer system are the lower and middle sands of the Potomac-Raritan-Magothy aquifer system. The lower sand unit is the most productive aquifer in Philadelphia. The median yield of wells screened in the lower sand unit is 275 gal/min (gallons per minute), and yields of some wells are as high as 1,350 gal/min. The median specific capacity is 16 (gal/min)/ft (gallons per minute per foot of drawdown). The principal units of the unconsolidated unconfined-aquifer system are the upper sand unit of the Potomac-Raritan-Magothy aquifer system and the informally named Trenton gravel. The median yield of wells tapping these two undifferentiated units is 90 gal/min, and yields of some wells are as high as 1,370 gal/min. The median specific capacity is 12 (gal/min)/ft. The consolidated unconfined-aquifer system consists mainly of the Wissahickon Formation. The median yield of nondomestic wells that tap the Wissahickon Formation is 45 gal/min, and yields are as high as 350 gal/min. The median specific capacity is 0.5 (gal/min)/ft. Urbanization has considerably modified the hydrologic cycle in Philadelphia. Impervious surfaces have reduced recharge areas and evapotranspiration and have increased direct runoff. Leakage from the water-distribution system, which is supplied from the Delaware and Schuylkill Rivers, was about 60 to 72 Mgal/d (million gallons per day) in 1980. Groundwater infiltration to sewers is estimated to be as much as 135 Mgal/d when the water table is high. The potentiometric surface of the lower sand unit has been lowered substantially by pumping. By 1954, cones of depression were more than 50 ft (feet) below sea level at the U.S. Naval Base and more than 70 ft below sea level along the Delaware River northeast of the naval base. As a result of withdrawals, declining heads in the lower sand unit caused water to flow downward from the overlying unconsolidated deposits and the water table to decline below sea level along the Delaware River. Beginning in the mid1960's, ground-water withdrawals from the lower sand unit decreased, and, by 1979, water levels had risen 25 ft at the U.S. Naval Base and 45 ft farther north along the Delaware River. As of 1985, water levels in the lower sand unit were controlled largely by pumping in nearby parts of New Jersey. Urbanization also has caused substantial degradation of the quality of ground water in Philadelphia. By 1945, the quality of water in the unconfined aquifer system began to deteriorate as contaminants present at the land surface migrated down- ward. Withdrawal of water from the deeper confined aquifers caused a head decline that resulted in downward movement of contaminated water from the overlying unconfined aquifer system. Consequently, water in the confined aquifers deteriorated progressively in chemical quality so it resembles water in the unconfined aquifer system. The concentration of dissolved solids in water samples collected during 1979-80 ranged from 90 to 4,480 mg/L (milligrams per liter). The average concentration of 778 mg/L was 45 percent higher than that of samples collected during 1945-58. Water from the unconfined unconsolidated aquifers generally had the highest dissolved-solids concentration. The concentration of dissolved iron in water samples collected during 197980 ranged from 0 to 220 mg/L and exceeded 0.30 mg/L in 71 percent of the samples. The average concentration of 17 mg/L was nearly 30 percent higher than that of samples collected during 1945-58. Many wells have been abandoned because of elevated iron concentrations. The concentration of dissolved manganese in water

  20. Environmental setting of fixed sites in the western Lake Michigan drainages, Michigan and Wisconsin

    USGS Publications Warehouse

    Sullivan, D.J.; Peterson, E.M.; Richards, K.D.

    1995-01-01

    This report describes selected environmental- setting features for 11 fixed surface-water sites in the Western Lake Michigan Drainages study unit of the National Water-Quality Assessment Pro- gram. The study unit, which includes 10 major river systems draining to Lake Michigan, is bounded on the south by the Illinois State line and extends north to about 31 miles north of Escanaba, Mich. The fixed sites are on the following streams: Peshekee River, Popple River, Menominee River, Pensaukee River, Duck Creek, Tomorrow River, East River, Fox River, North Branch Milwaukee River, Lincoln Creek, and Milwaukee River. Drainage basins above these sites receive runoff from land uses and land covers, bedrock types, and surficial deposits representative of the main types of each of these characteristics in the study unit. Data types collected at the fixed sites include water chemistry; organic compounds and trace elements in streambed sediment and biological tissues; algal, benthic-invertebrate, and fish communities; and aquatic habitat. Field measurements include water temperature, pH, specific conductance, alkalinity, and dissolved oxygen. Results of water- quality field measurements indicate little variation in temperature among the fixed sites. Specific conductance and alkalinity were generally higher at sites underlain by carbonate bedrock than at sites underlain by igneous/metamorphic bedrock. Differences in pH among the fixed sites were less than those for specific conductance and alkalinity, but pH seemed to increase slightly from north to south. Dissolved-oxygen concentration varied more at agricultural sites than at forested and urban sites, perhaps because of higher nutrient inputs at agricultural sites. The information included in this report has been assembled as reference material for ongoing studies at the fixed sites.

  1. DETECTION OF EXTREMELY BROAD WATER EMISSION FROM THE MOLECULAR CLOUD INTERACTING SUPERNOVA REMNANT G349.7+0.2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rho, J.; Hewitt, J. W.; Boogert, A.

    2015-10-10

    We performed Herschel HIFI, PACS, and SPIRE observations toward the molecular cloud interacting supernova remnant G349.7+0.2. An extremely broad emission line was detected at 557 GHz from the ground state transition 1{sub 10}-1{sub 01} of ortho-water. This water line can be separated into three velocity components with widths of 144, 27, and 4 km s{sup −1}. The 144 km s{sup −1} component is the broadest water line detected to date in the literature. This extremely broad line width shows the importance of probing shock dynamics. PACS observations revealed three additional ortho-water lines, as well as numerous high-J carbon monoxide (CO)more » lines. No para-water lines were detected. The extremely broad water line is indicative of a high velocity shock, which is supported by the observed CO rotational diagram that was reproduced with a J-shock model with a density of 10{sup 4} cm{sup −3} and a shock velocity of 80 km s{sup −1}. Two far-infrared fine-structure lines, [O i] at 145 μm and [C ii] line at 157 μm, are also consistent with the high velocity J-shock model. The extremely broad water line could be simply from short-lived molecules that have not been destroyed in high velocity J-shocks; however, it may be from more complicated geometry such as high-velocity water bullets or a shell expanding in high velocity. We estimate the CO and H{sub 2}O densities, column densities, and temperatures by comparison with RADEX and detailed shock models.« less

  2. Nitrate and drinking water from private wells: will there be an epidemic of cancers of the digestive tract, urinary bladder and thyroid?

    PubMed

    Njeze, G E; Dilibe, U; Ilo, C

    2014-01-01

    To estimate the nitrate levels in private wells located in different parts of Enugu and discuss the future health implications following chronic ingestion of well water. The map of Enugu was used to divide the city into many 25 units, using grid lines 1 cm apart. Cluster sampling method was used to collect samples. These samples were sent to two laboratories for estimation of nitrate levels. The people drawing water from the different wells were interviewed to determine what they used the water for. The subjects who were interviewed said they ingested the water. The nitrate levels found in these wells (median value of 31 mg/L) were significantly higher than the internationally accepted levels of nitrate in water for ingestion, (P < 0.0001). High nitrate levels drinking water is dangerous to health and can cause methemoglobinemia in children. It may also increase cancer risk in adults because nitrate is endogenously reduced to nitrite and subsequent nitrosation reactions give rise to N-nitroso compounds (NOCs), which are highly carcinogenic and can act systemically.

  3. Use of induced polarization to characterize the hydrogeologic framework of the zone of surface‐water/groundwater exchange at the Hanford 300 Area, WA

    USGS Publications Warehouse

    Slater, Lee; Ntarlagiannis, Dimitrios; Day-Lewis, Frederick D.; Mwakanyamale, Kisa; Lane, John W.; Ward, Andy; Versteeg, Roelof J.

    2010-01-01

    An extensive continuous waterborne electrical imaging (CWEI) survey was conducted along the Columbia River corridor adjacent to the U.S. Department of Energy (DOE) Hanford 300 Area, WA, in order to improve the conceptual model for exchange between surface water and U‐contaminated groundwater. The primary objective was to determine spatial variability in the depth to the Hanford‐Ringold (H‐R) contact, an important lithologic boundary that limits vertical transport of groundwater along the river corridor. Resistivity and induced polarization (IP) measurements were performed along six survey lines parallel to the shore (each greater than 2.5 km in length), with a measurement recorded every 0.5–3.0 m depending on survey speed, resulting in approximately 65,000 measurements. The H‐R contact was clearly resolved in images of the normalized chargeability along the river corridor due to the large contrast in surface area (hence polarizability) of the granular material between the two lithologic units. Cross sections of the lithologic structure along the river corridor reveal a large variation in the thickness of the overlying Hanford unit (the aquifer through which contaminated groundwater discharges to the river) and clearly identify locations along the river corridor where the underlying Ringold unit is exposed to the riverbed. Knowing the distribution of the Hanford and Ringold units along the river corridor substantially improves the conceptual model for the hydrogeologic framework regulating U exchange between groundwater and Columbia River water relative to current models based on projections of data from boreholes on land into the river.

  4. Potential of Near-Infrared Chemical Imaging as Process Analytical Technology Tool for Continuous Freeze-Drying.

    PubMed

    Brouckaert, Davinia; De Meyer, Laurens; Vanbillemont, Brecht; Van Bockstal, Pieter-Jan; Lammens, Joris; Mortier, Séverine; Corver, Jos; Vervaet, Chris; Nopens, Ingmar; De Beer, Thomas

    2018-04-03

    Near-infrared chemical imaging (NIR-CI) is an emerging tool for process monitoring because it combines the chemical selectivity of vibrational spectroscopy with spatial information. Whereas traditional near-infrared spectroscopy is an attractive technique for water content determination and solid-state investigation of lyophilized products, chemical imaging opens up possibilities for assessing the homogeneity of these critical quality attributes (CQAs) throughout the entire product. In this contribution, we aim to evaluate NIR-CI as a process analytical technology (PAT) tool for at-line inspection of continuously freeze-dried pharmaceutical unit doses based on spin freezing. The chemical images of freeze-dried mannitol samples were resolved via multivariate curve resolution, allowing us to visualize the distribution of mannitol solid forms throughout the entire cake. Second, a mannitol-sucrose formulation was lyophilized with variable drying times for inducing changes in water content. Analyzing the corresponding chemical images via principal component analysis, vial-to-vial variations as well as within-vial inhomogeneity in water content could be detected. Furthermore, a partial least-squares regression model was constructed for quantifying the water content in each pixel of the chemical images. It was hence concluded that NIR-CI is inherently a most promising PAT tool for continuously monitoring freeze-dried samples. Although some practicalities are still to be solved, this analytical technique could be applied in-line for CQA evaluation and for detecting the drying end point.

  5. Diagenesis of the Oligocene-Miocene rocks of the Upper Floridan and Intermediate aquifer systems by meteoric and mixing-zone waters in southwest Florida

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weedman, S.D.; McCartan, L.

    1993-03-01

    Optical and SEM of samples from 6 cores of Oligocene and Miocene rocks that compose portions of the Florida and Intermediate aquifers and the intervening semiconfining unit documents meteoric and mixing-zone (seawater and fresh carbonate ground water) diagenesis inferred to have occurred over several cycles of sea level change. Dolomite, limestone, sandstone, and claystone of the Suwannee Formation and the Arcadia Formation (Hawthorn Group) were examined. Core samples from time-equivalent strata in two E--W transects in Manatee, Hardee, Highlands, Sarasota, and DeSoto Counties are estimated to be 16--33 Ma on the basis of [sup 87]Sr/[sup 86]Sr ratios from unaltered molluskmore » shells and by molluscan biostratigraphy. Lithostratigraphic correlations are based on examination of 19 cores, 62 thin sections, 60 geophysical logs, and mineralogy determined by X-ray diffraction. Diagenetic indicators that the authors tracked petrographically include shell micritization, shell dissolution, equant and (or) fibrous CaCO[sub 3] cement, neomorphism, dolomite, etched phosphate grains, echinoderm fragment syntaxial overgrowths, and amorphous silica pore lining. Infiltration of meteoric water caused dissolution of carbonate minerals, especially aragonite, and precipitation of equant calcite crystals in voids of dissolved fossils and in pore spaces between grains. The silica was precipitated as pore linings in zones having soil textures. Observed replacement of calcite by limpid dolomite is consistent with modeling predictions of mixing-zone diagenesis. Etched crystals of limpid dolomite may indicate freshwater dissolution of a mixing-zone precipitate. Mapping of regional unconformities revealed pronounced thickening and thinning of some units. Evidence of meteoric water diagenesis is observed in the upper 600 ft of the transects examined. Evidence of mixing-zone diagenesis is observed at varying depths, but appears to increase in abundance and thickness toward the west.« less

  6. Global water resources affected by human interventions and climate change.

    PubMed

    Haddeland, Ingjerd; Heinke, Jens; Biemans, Hester; Eisner, Stephanie; Flörke, Martina; Hanasaki, Naota; Konzmann, Markus; Ludwig, Fulco; Masaki, Yoshimitsu; Schewe, Jacob; Stacke, Tobias; Tessler, Zachary D; Wada, Yoshihide; Wisser, Dominik

    2014-03-04

    Humans directly change the dynamics of the water cycle through dams constructed for water storage, and through water withdrawals for industrial, agricultural, or domestic purposes. Climate change is expected to additionally affect water supply and demand. Here, analyses of climate change and direct human impacts on the terrestrial water cycle are presented and compared using a multimodel approach. Seven global hydrological models have been forced with multiple climate projections, and with and without taking into account impacts of human interventions such as dams and water withdrawals on the hydrological cycle. Model results are analyzed for different levels of global warming, allowing for analyses in line with temperature targets for climate change mitigation. The results indicate that direct human impacts on the water cycle in some regions, e.g., parts of Asia and in the western United States, are of the same order of magnitude, or even exceed impacts to be expected for moderate levels of global warming (+2 K). Despite some spread in model projections, irrigation water consumption is generally projected to increase with higher global mean temperatures. Irrigation water scarcity is particularly large in parts of southern and eastern Asia, and is expected to become even larger in the future.

  7. Global water resources affected by human interventions and climate change

    PubMed Central

    Haddeland, Ingjerd; Heinke, Jens; Biemans, Hester; Eisner, Stephanie; Flörke, Martina; Hanasaki, Naota; Konzmann, Markus; Ludwig, Fulco; Masaki, Yoshimitsu; Schewe, Jacob; Stacke, Tobias; Tessler, Zachary D.; Wada, Yoshihide; Wisser, Dominik

    2014-01-01

    Humans directly change the dynamics of the water cycle through dams constructed for water storage, and through water withdrawals for industrial, agricultural, or domestic purposes. Climate change is expected to additionally affect water supply and demand. Here, analyses of climate change and direct human impacts on the terrestrial water cycle are presented and compared using a multimodel approach. Seven global hydrological models have been forced with multiple climate projections, and with and without taking into account impacts of human interventions such as dams and water withdrawals on the hydrological cycle. Model results are analyzed for different levels of global warming, allowing for analyses in line with temperature targets for climate change mitigation. The results indicate that direct human impacts on the water cycle in some regions, e.g., parts of Asia and in the western United States, are of the same order of magnitude, or even exceed impacts to be expected for moderate levels of global warming (+2 K). Despite some spread in model projections, irrigation water consumption is generally projected to increase with higher global mean temperatures. Irrigation water scarcity is particularly large in parts of southern and eastern Asia, and is expected to become even larger in the future. PMID:24344275

  8. 40 CFR Table 37 to Subpart Uuu of... - Requirements for Performance Tests for Bypass Lines

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Bypass Lines 37 Table 37 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION...: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 37 Table 37 to Subpart UUU of Part 63—Requirements for Performance Tests for Bypass Lines As stated in § 63...

  9. 40 CFR Table 36 to Subpart Uuu of... - Work Practice Standards for HAP Emissions From Bypass Lines

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Emissions From Bypass Lines 36 Table 36 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL... Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 36 Table 36 to Subpart UUU of Part 63—Work Practice Standards for HAP Emissions From Bypass Lines...

  10. 40 CFR Table 37 to Subpart Uuu of... - Requirements for Performance Tests for Bypass Lines

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Bypass Lines 37 Table 37 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION...: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 37 Table 37 to Subpart UUU of Part 63—Requirements for Performance Tests for Bypass Lines As stated in § 63...

  11. 40 CFR Table 36 to Subpart Uuu of... - Work Practice Standards for HAP Emissions From Bypass Lines

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Emissions From Bypass Lines 36 Table 36 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL... Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 36 Table 36 to Subpart UUU of Part 63—Work Practice Standards for HAP Emissions From Bypass Lines...

  12. Physiological response and productivity of safflower lines under water deficit and rehydration.

    PubMed

    Bortolheiro, Fernanda P A P; Silva, Marcelo A

    2017-01-01

    Water deficit is one of the major stresses affecting plant growth and productivity worldwide. Plants induce various morphological, physiological, biochemical and molecular changes to adapt to the changing environment. Safflower (Carthamus tinctorius L.), a potential oil producer, is highly adaptable to various environmental conditions, such as lack of rainfall and temperatures. The objective of this work was to study the physiological and production characteristics of six safflower lines in response to water deficit followed by rehydration. The experiment was conducted in a protected environment and consisted of 30 days of water deficit followed by 18 days of rehydration. A differential response in terms of photosynthetic pigments, electrolyte leakage, water potential, relative water content, grain yield, oil content, oil yield and water use efficiency was observed in the six lines under water stress. Lines IMA 04, IMA 10, IMA 14 showed physiological characteristics of drought tolerance, with IMA 14 and IMA 16 being the most productive after water deficit. IMA 02 and IMA 21 lines displayed intermediate characteristics of drought tolerance. It was concluded that the lines responded differently to water deficit stress, showing considerable genetic variation and influence to the environment.

  13. 8 CFR 233.4 - Preinspection outside the United States.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 8 Aliens and Nationality 1 2014-01-01 2014-01-01 false Preinspection outside the United States... CONTRACTS WITH TRANSPORTATION LINES § 233.4 Preinspection outside the United States. (a) Form I-425 agreements. A transportation line bringing applicants for admission to the United States through...

  14. 8 CFR 233.4 - Preinspection outside the United States.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 8 Aliens and Nationality 1 2011-01-01 2011-01-01 false Preinspection outside the United States... CONTRACTS WITH TRANSPORTATION LINES § 233.4 Preinspection outside the United States. (a) Form I-425 agreements. A transportation line bringing applicants for admission to the United States through...

  15. Ground-water contamination in East Bay Township, Michigan

    USGS Publications Warehouse

    Twenter, F.R.; Cummings, T.R.; Grannemann, N.G.

    1985-01-01

    Glacial deposits, as much as 360 feet thick, underlie the study area. The upper 29 to 118 feet, a sand and gravel unit, is the aquifer tapped for water by all wells in the area. This unit is underlain by impermeable clay that is at least 100 feet thick. Ground-water flow is northeastward at an estimated rate of 3 to 6 feet per day. Hydraulic conductivities in the aquifer range from 85 to 150 feet per day; 120 feet per day provided the best match of field data in a ground-water flow model. The depth to water ranged from 1 to 20 feet. Chemical anlayses indicate that ground water is contaminated with organic chemicals from near the Hangar/Administration building at the U.S. Coast Guard Air Station to East Bay, about 4,300 feet northeast. The plume, which follows ground-water flow lines, ranges from 180 to 400 feet wide. In the upper reach of the plume, hydrocarbons less dense than water occur at the surface of the water table; they move downward in the aquifer as they move toward East Bay. Maximum concentrations of the major organic compounds include: benzene, 3,390 micrograms per liter; toluene, 55,500 micrograms per liter; xylene, 3,900 micrograms per liter; tetrachloroethylene, 3,410 micrograms per liter; and bis (2-ethyl hexyl) phthalate, 2,100 micrograms per liter. Soils are generally free of these hydrocarbons; however, in the vicinity of past drum storage, aircraft maintenance operations, and fuel storage and dispensing, as much as 1,100 micrograms per kilogram of tetrachloroethylene and 1,500 micrograms per kilogram of bis (2-ethyl hexyl) phthalate were detected. At a few locations higher molecular weight hydrocarbons, characteristic of petroleum distillates, were found.

  16. Water Stress and Foliar Boron Application Altered Cell Wall Boron and Seed Nutrition in Near-Isogenic Cotton Lines Expressing Fuzzy and Fuzzless Seed Phenotypes

    PubMed Central

    2015-01-01

    Our previous research, conducted under well-watered conditions without fertilizer application, showed that fuzziness cottonseed trait resulted in cottonseed nutrition differences between fuzzy (F) and fuzzless (N) cottonseed. Under water stress conditions, B mobility is further limited, inhibiting B movement within the plant, affecting seed nutrition (quality). Therefore, we hypothesized that both foliar B and water stress can affect B mobility, altering cottonseed protein, oil, and mineral nutrition. The objective of the current research was to evaluate the effects of the fuzziness seed trait on boron (B) and seed nutrition under water stress and foliar B application using near-isogenic cotton lines (NILs) grown in a repeated greenhouse experiment. Plants were grown under-well watered conditions (The soil water potential was kept between -15 to -20 kPa, considered field capacity) and water stress conditions (soil water potential between -100 and -150 kPa, stressed conditions). Foliar B was applied at a rate of 1.8 kg B ha-1 as H3BO3. Under well-watered conditions without B the concentrations of seed oil in N lines were higher than in F lines, and seed K and N levels were lower in N lines than in F lines. Concentrations of K, N, and B in leaves were higher in N lines than in F lines, opposing the trend in seeds. Water-stress resulted in higher seed protein concentrations, and the contribution of cell wall (structural) B to the total B exceeded 90%, supporting the structural role of B in plants. Foliar B application under well-watered conditions resulted in higher seed protein, oil, C, N, and B in only some lines. This research showed that cottonseed nutrition differences can occur due to seed fuzziness trait, and water stress and foliar B application can alter cottonseed nutrition. PMID:26098564

  17. Shelf life determinants and enzyme activities of pearl millet: a comparison of changes in stored flour of hybrids, CMS lines, inbreds and composites.

    PubMed

    Goyal, Preeti; Chugh, L K

    2017-09-01

    Shelf life of pearl millet flour is very short because of rapid development of rancidity. This investigation was carried out in view of generating breeding material for development of low rancid pearl millet hybrids/varieties. Flour of twenty-one genotypes; seven hybrids, seven CMS lines, five inbreds and two composites stored in covered aluminium boxes at 37 °C for 30 days along with respective fresh flour was analysed for shelf life indicators/determinants. Crude fat content and fat acidity (FA) of fresh flour of the genotypes varied from 3.8 to 7.2% and 11 to 75 mg KOH/100 g d.m., respectively. FA in stored flour ranged between 180 and 330 mg KOH/100 g d.m. After storage, magnitude of decrease in pH of water extract of flour of the genotypes varied from 0.15 to 0.44. Activity of peroxidase (POX) varied from 378 to 588 units in control flour and irrespective of the genotypes decreased upon storage. Increase in FA (difference between FA of fresh and stored flour) rather total build up of FA was positively associated with crude fat content (r = 0.440*) indicated comparatively more prominent role of lipolytic enzymes. Chemical changes taking place in water soluble fraction of flour were independent of fat content as no correlation was discerned between fat content and decrease in pH. Among the hybrids, HHB 197 had lowest crude fat content (4.7%), lowest total build up FA (212 mg KOH/100 g d.m.), slowest increase in FA (191 mg KOH/100 g d.m.), least decrease in pH (0.31) of water soluble fraction flour during storage and lowest activity of POX in fresh flour (377 units/g d.m). Among all the tested CMS lines, inbreds and composites, HBL 11 showed pattern of quantitative changes in FA, pH and POX activity similar to the hybrid HHB 197 and was identified a promising inbred for developing low-rancid pearl millet variety or hybrid.

  18. Interactive chemistry management system (ICMS); Field demonstration results at United Illuminating

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Noto, F.A.; Farrell, D.M.; Lombard, E.V.

    1988-01-01

    The authors report on a field demonstration of the interactive chemistry management system (ICMS) performed in the late summer of 1987 at the New Haven Harbor Station of United Illuminating Co. This demonstration was the first installation of the ICMS at an actual plant site. The ICMS is a computer-based system designed to monitor, diagnose, and provide optional automatic control of water and steam chemistry throughout the steam generator cycle. It is one of the diagnostic modules that comprises CE-TOPS (combustion engineering total on-line performance system), which continuously monitors operating conditions and suggests priority actions to increase operation efficiency, extendmore » the performance life of boiler components and reduce maintenance costs. By reducing the number of forced outages through early identification of potentially detrimental conditions, diagnosis of possible causes, and execution of corrective actions, improvements in unit availability and reliability will result.« less

  19. Determination of minimum suction level necessary for field dental units.

    PubMed

    Charlton, David G

    2010-04-01

    A significant problem with most field dental units is that their suction is too weak to effectively remove debris from the mouth. The purpose of this study was to determine the minimum clinically acceptable suction level for routine dentistry. A vacuum pump was connected to a high-volume dental evacuation line in a simulated clinical setting and different suction airflow rates were evaluated by nine evaluator dentists for their capability to effectively remove amalgam debris and water. Airflow levels were rated as "clinically acceptable" or "clinically unacceptable" by each evaluator. Data were analyzed using a chi2 test for trend. Analysis indicated a significant linear trend between airflow and ratings (p < 0.0001). The first airflow level considered by all evaluators as producing clinically acceptable suction was 4.5 standard cubic feet per minute (0.127 standard cubic meters per minute). This value should be the minimum level required for all military field dental units.

  20. Hydrogeology and the distribution of salinity in the Floridan Aquifer system, southwestern Florida

    USGS Publications Warehouse

    Reese, R.S.

    2000-01-01

    In most of the study area, the Floridan aquifer system can be divided into a brackish-water zone, a salinity transition zone, and a saline-water zone. The brackish-water zone contains water with a dissolved-solids concentration of less than 10,000 milligrams per liter. The saline-water zone has a dissolved-solids concentration of at least 35,000 milligrams per liter and a salinity similar to that of seawater. The salinity transition zone that separates these two zones is usually 150 feet or less in thickness. The altitude of the base of the brackish-water zone was mapped primarily using geophysical logs; it ranges from as shallow as 565 feet below sea level along the coast to almost 2,200 feet below sea level inland. This mapping indicated that the boundary represents a salinity interface, the depth of which is controlled by head in the brackish-water zone. Chloride concentrations in the upper part of the brackish-water zone range from 400 to 4,000 milligrams per liter. A large area of relatively low salinity in north-central Collier County and to the northwest, as defined by a 1,200-milligram-per-liter chloride-concentration line, coincides with a high area on the basal contact of the Hawthorn Group. As this contact dips away from this high area to central Hendry and southwestern Collier Counties, chloride concentration increases to 2,000 milligrams per liter or greater. However, the increase in salinity in these areas occurs only in the basal Hawthorn unit or Suwannee Limestone, but not in deeper units. In central Hendry County, the increase occurs only in the basal Hawthorn unit in an area where the unit is well developed and thick. These areas of higher salinity could have resulted from the influx of seawater from southwestern Collier County into zones of higher permeability in the Upper Floridan aquifer during high sea-level stands. The influx may only have occurred in structurally low areas and may have experienced incomplete flushing subsequently by the modern freshwater flow system. In an area in north-central Collier County, the altitude of the base of the brackish-water zone is anomalously deep given the position of this area relative to the coast. In this area, the base extends as deep as 2,090 feet below sea level, and the salinity transition zone is not present or is poorly defined. The origin of this anomalous area is interpreted to be related to the development of a unit containing thick dolomite and evaporite beds high in the middle confining unit of the Floridan aquifer system. The top of this dolomite-evaporite unit, which probably has very low permeability, occurs at the base of the brackish-water zone in this area. The axis of a high area mapped at the top of the unit trends to the northwest from central Collier County into north-central Lee County. This axis parallels and lies just to the west of the anomalous area, and it could have acted as an impermeable sill, preventing saline water from moving in laterally from the coast to the southwest and up from the Lower Floridan aquifer. Locating a Floridan aquifer system well field in or near this anomalous area could be optimal because of the lack of a salinity interface at depth.

  1. Domestic wash-water reclamation using an aerospace-developed water recovery subsystem

    NASA Technical Reports Server (NTRS)

    Hall, J. B., Jr.

    1973-01-01

    A prototype aerospace distillation water recovery subsystem was tested to determine its capability to recover potable water from domestic wash water. A total of 0.0994 cu m (26.25 gallons) of domestic wash water was processed over a 7-day period at an average process rate of 0.0146 cu m per day (3.85 gallons per day). The subsystem produced water that met all United States Public Health Standards for drinking water with the exception of two standards which could not be analyzed at the required sensitivity levels. Average energy consumption for this evaluation to maintain both the recovery process and microbial control in the recovered water was approximately 3366 kilowatt-hours per cubic meter (12.74 kilowatt-hours per gallon) of water recovered. This condition represents a worst case energy consumption since no attempt was made to recover heat energy in the subsystem. An ultraviolet radiation cell installed in the effluent line of the subsystem was effective in controlling coliform micro-organisms within acceptable levels for drinking water. The subsystem recovered virtually 100 percent of the available water in the waste-water process. In addition, the subsystem removed 99.6 percent and 98.3 percent of the surfactants and phosphate, respectively, from the wash water.

  2. Metastable equilibria among dicarboxylic acids and the oxidation state during aqueous alteration on the CM2 chondrite parent body

    NASA Astrophysics Data System (ADS)

    McAlister, Jason A.; Kettler, Richard M.

    2008-01-01

    Linear saturated dicarboxylic acids are present in carbonaceous chondrite samples at concentrations that suggest aqueous alteration under conditions of metastable equilibrium. In this study, previously published values of dicarboxylic acid concentrations measured in Murchison, Yamato-791198, and Tagish Lake carbonaceous chondrites are converted to aqueous activities during aqueous alteration assuming water:rock ratios that range from 1:10 to 10:1. Logarithmic plots of the aqueous activities of any two dicarboxylic acids are proximal to lines whose slope is fixed by the stoichiometry of reactions describing the oxidation-reduction equilibrium between the two species. The precise position of any line is controlled by the equilibrium constant of the reaction relating the species and the hydrogen fugacity for the reaction of interest. Reactions among succinic (C4), glutaric (C5), and adipic (C6) acids obtained from CM2 chondrites show evidence of metastable equilibrium and yield logf values that agree to within 0.3 log units at 298.15 K and 0.6 log units at 473.15 K. At a water:rock ratio of 1:1, metastable equilibrium among succinic, glutaric, and adipic acids results in calculated logf values during aqueous alteration that range from -6.2 at 298.15 K to -3.3 at 373.15 K. These values are consistent with those obtained in previous work on carbonaceous chondrites and with metastable equilibrium at temperatures ranging from 300 to 355 K in contact with cronstedtite + magnetite.

  3. Radiation Measurement Systems and Experiences in Japan after the Fukushima Accident

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    In the approximately 4 years since the March 2011 earthquake and subsequent Tsunami damaged the three Dai-Ichi nuclear power plants, the AREVA and Canberra team have deployed a variety of different radiation measurement machines in Japan. These measurement projects or instruments include: - Dose-rate mapping of the close-in areas on the damaged reactor site using the stored output of dose rate meters carried by workers planning for the installing of a water processing unit; - Spectroscopic on-line measurements of the first water processing unit on the site, where these nuclide-specific measurements at multiple points allowed remote users to determine themore » optimum processing parameters - General purpose food measurement units, both high precision HPGe systems and low cost NaI systems, which were used throughout the country for food quality measurements; - In-vivo measurement systems, both fixed and mobile whole body counting units, that were used on at least 500,000 people, demonstrating to them that internal doses were very low; - In-vivo measurements with special high-sensitivity whole body counters on babies and children, demonstrating to the parents of these children that internal doses are very low; - Automatic systems for high throughput assay of bags of rice that are part of the consumer confidence plan to prove to customers that Fukushima Prefecture rice is safe; - High sensitivity automatic system to assay boxes of special semi-dry persimmons and to report the activity of each individual item within the box meets the regulatory limit; - System to assay soil on a conveyor belt and sort the output according to level of radioactivity, which would then reduce the volume of material that must be treated as radioactive; - System to assay a truck loaded with 1 cubic meter sacks of soil and vegetation, and report the results of each individual sack. - On-line water measurement system for SrY90 at levels that are suitable for release to the environment; - Mobile system to prove that rolls of grass harvested for animal feed meet the regulatory requirements. This document briefly describes the purpose of each measurement project, describes the instruments and assay method that used, and discusses some of the operational experiences from each of these projects. (authors)« less

  4. 46 CFR 46.15-10 - Subdivision load lines.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 45 and a “diamond” shall be substituted for the “disk”. No “fresh water” line will be marked. [CGFR... located in line with the highest subdivision load line. (f) One fresh water line shall be marked. When a subdivision and a normal load line are combined, the normal fresh water line only shall be used unless the...

  5. Sagebrush Flat Wildlife Area 2008 Annual Report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peterson, Dan

    The Sagebrush Flat Wildlife Area is a 12,718 acre complex located in Douglas County, Washington. Four distinct management units make up the area: Bridgeport, Chester Butte, Dormaier and Sagebrush Flat. The four Units are located across a wide geographic area within Douglas County. The Units are situated roughly along a north/south line from Bridgeport in the north to the Douglas/Grant county line in the south, 60 miles away. The wildlife area was established to conserve and enhance shrubsteppe habitat for the benefit shrubsteppe obligate and dependent wildlife species. In particular, the Sagebrush Flat Wildlife Area is managed to promote themore » recovery of three state-listed species: Columbian sharp-tailed grouse (threatened), greater sage grouse (threatened) and the pygmy rabbit (endangered). The US Fish and Wildlife Service also list the pygmy rabbit as endangered. Wildlife area staff seeded 250 acres of old agricultural fields located on the Sagebrush Flat, Dormaier and Chester Butte units. This has been a three project to reestablish high quality shrubsteppe habitat on fields that had either been abandoned (Dormaier) or were dominated by non-native grasses. A mix of 17 native grasses and forbs, most of which were locally collected and grown, was used. First year maintenance included spot spraying Dalmatian toadflax on all sites and mowing annual weeds to reduce competition. Photo points were established and will be integral to long term monitoring and evaluation. Additional monitoring and evaluation will come from existing vegetation transects. This year weed control efforts included spot treatment of noxious weeds, particularly Dalmatian toadflax, in previously restored fields on the Bridgeport Unit (150 acres). Spot treatment also took place within fields scheduled for restoration (40 acres) and in areas where toadflax infestations are small and relatively easily contained. Where toadflax is so widespread that chemical treatment would be impractical, we use the bioagent Mecinus janthinus, available through Professor Gary Piper of Washington State University. This year we released 4,000 M. janthinus on the Bridgeport Unit at 6 separate locations. Since 2002 we have released approximately 14,400 of these insects, 80% of these on the Bridgeport Unit. Additional weed control activities included mowing and spot spraying more than 32 miles of roads, cutting and removal of annual weeds within fenced deer exclosures. We upgraded the solar powered irrigation system that supplies water to a stand of water birch trees planted in 2002. Wildlife area staff designed and built a new solar array and installed a higher capacity pump. The increased capacity will ensure that these trees receive adequate water through the hot summer months and allow us to create at least one additional stand. This project is an important part in our effort to expand the available winter habitat for sharp-tailed grouse on the Bridgeport Unit. Maintenance of fences, parking areas and roads continued during throughout the year. Two parking areas, at Chester Butte and Bridgeport, were graded and additional gravel added. Roads on the Bridgeport Unit were graded and repaired following spring runoff. Trespass and dumping issues have increased in recent years on the Bridgeport Unit. To address these problems we constructed four steel gates at access points on this unit. Each gate is tubular steel attached to 8-inch diameter steel posts, 10 feet long that are cemented into the ground. Two gates allow access to BPA substation facilities and power-line right-of ways so placement, construction and locking issues had to be coordinated with BPA's Real Estate staff in Spokane. Environmental Compliance Documentation issues were addressed again this year. This process has the potential to cause delays the completion of projects within the fiscal year. With this in mind and an eye toward the future, we requested that several projects planned for the coming years be surveyed this year. Beginning in August of 2007, area staff worked with BPA staff to identify work elements that had the potential to disturb cultural resources. Subsequently, in April of 2008, BPA staff archaeologists surveyed numerous sites and several miles of fence line. Final clearance to proceed was granted in August of 2008. This year we submitted and were awarded a grant from the state Recreation and Conservation Office. This grant will provide funding to restore native shrubsteppe habitat on 335 acres of old CRP fields located on the Bridgeport Unit. These fields were planted to non-native grasses in 1988 and currently have marginal habitat values for shrubsteppe obligate and dependent wildlife. Assuming that the state legislature allocates the funds, which, given the state's financial condition is not a sure thing, work on this project can begin late in the summer of 2009.« less

  6. 46 CFR 7.120 - Mexican/United States border to Point Fermin, CA.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... BOUNDARY LINES Pacific Coast § 7.120 Mexican/United States border to Point Fermin, CA. (a) A line drawn... 46 Shipping 1 2014-10-01 2014-10-01 false Mexican/United States border to Point Fermin, CA. 7.120... “5”); thence to Point Loma Light. (b) A line drawn from Mission Bay South Jetty Light “2” to Mission...

  7. 46 CFR 7.120 - Mexican/United States border to Point Fermin, CA.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... BOUNDARY LINES Pacific Coast § 7.120 Mexican/United States border to Point Fermin, CA. (a) A line drawn... 46 Shipping 1 2012-10-01 2012-10-01 false Mexican/United States border to Point Fermin, CA. 7.120... “5”); thence to Point Loma Light. (b) A line drawn from Mission Bay South Jetty Light “2” to Mission...

  8. 46 CFR 7.120 - Mexican/United States border to Point Fermin, CA.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... BOUNDARY LINES Pacific Coast § 7.120 Mexican/United States border to Point Fermin, CA. (a) A line drawn... 46 Shipping 1 2010-10-01 2010-10-01 false Mexican/United States border to Point Fermin, CA. 7.120... “5”); thence to Point Loma Light. (b) A line drawn from Mission Bay South Jetty Light “2” to Mission...

  9. 46 CFR 7.120 - Mexican/United States border to Point Fermin, CA.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... BOUNDARY LINES Pacific Coast § 7.120 Mexican/United States border to Point Fermin, CA. (a) A line drawn... 46 Shipping 1 2013-10-01 2013-10-01 false Mexican/United States border to Point Fermin, CA. 7.120... “5”); thence to Point Loma Light. (b) A line drawn from Mission Bay South Jetty Light “2” to Mission...

  10. 46 CFR 7.120 - Mexican/United States border to Point Fermin, CA.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... BOUNDARY LINES Pacific Coast § 7.120 Mexican/United States border to Point Fermin, CA. (a) A line drawn... 46 Shipping 1 2011-10-01 2011-10-01 false Mexican/United States border to Point Fermin, CA. 7.120... “5”); thence to Point Loma Light. (b) A line drawn from Mission Bay South Jetty Light “2” to Mission...

  11. Electromigration model for the prediction of lifetime based on the failure unit statistics in aluminum metallization

    NASA Astrophysics Data System (ADS)

    Park, Jong Ho; Ahn, Byung Tae

    2003-01-01

    A failure model for electromigration based on the "failure unit model" was presented for the prediction of lifetime in metal lines.The failure unit model, which consists of failure units in parallel and series, can predict both the median time to failure (MTTF) and the deviation in the time to failure (DTTF) in Al metal lines. The model can describe them only qualitatively. In our model, both the probability function of the failure unit in single grain segments and polygrain segments are considered instead of in polygrain segments alone. Based on our model, we calculated MTTF, DTTF, and activation energy for different median grain sizes, grain size distributions, linewidths, line lengths, current densities, and temperatures. Comparisons between our results and published experimental data showed good agreements and our model could explain the previously unexplained phenomena. Our advanced failure unit model might be further applied to other electromigration characteristics of metal lines.

  12. Chemical and isotopic constraints on the origin of Wadi El-Tarfa ground waters, Eastern Desert, Egypt.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sultan, M.; Sturchio, N. C.; Abdel Hady, Y.

    2000-10-01

    We evaluated the use of the renewable ground water resources of the Eastern Desert to develop sustainable agriculture in Upper Egypt, an alternative that could alleviate some of Egypt's dependence on water from the Nile River. Ground water from shallow aquifers in the Eastern Desert of Egypt, near the intersection of Wadi El-Tarfa and the Nile River, was analyzed for chemical compositions, stable isotope ratios, and tritium activities. The ground water has a range in total dissolved solids of 300 to 5000 mg/L. Values of {delta}D and {delta}{sup 18}O range from -10 to +34 %o and -2 to +5.2 %o,more » respectively, and defines a line having a slope of 5.7 that intersects the meteoric water line at about {delta}D = -15% on a plot of 8D versus {delta}{sup 18}O. These findings indicate that the water might have been derived by a combination of evaporation of and salt addition to regional precipitation. Only one sample could have been derived directly by evaporation and transpiration of modern Nile River water. Salinization of the ground water could have occurred through dissolution of marine aerosol dry fallout, carbonate minerals, gypsum, and other trace evaporitic minerals at and near the ground surface. Tritium activities ranged from 0.04 to 12.9 TU (tritium unite), indicating that all but one of the samples were derived at least partly from precipitation that occurred within the last 45 years. These data indicate that Nubian Aquifer paleowater is not a significant component of the shallow aquifers of this portion of the Eastern Desert. The most likely source of this ground water is sporadic flash flood events yielding locally voluminous recharge that accumulates in coarse sediments and fractured rock beneath alluvial channels. The magnitude of this renewable ground water resource and its potential for supporting sustainable agriculture require further investigation.« less

  13. Absolute frequencies of water lines near 790 nm with 10-11 accuracy

    NASA Astrophysics Data System (ADS)

    Chen, J.; Hua, T.-P.; Tao, L.-G.; Sun, Y. R.; Liu, A.-W.; Hu, S.-M.

    2018-01-01

    Water lines in the infrared are convenient frequency references. We present absolute positions of several H216O ro-vibrational transitions around 790 nm using comb-locked cavity ring-down saturation spectroscopy. Lamb dips of 6 water lines with saturation power in the range of 70-130 kW/cm2 were observed and the line positions were determined with an accuracy of 25 kHz, corresponding to a fractional uncertainty of 6.6 × 10-11. The present work demonstrates the capability to considerably improve the accuracy of the water line positions in the infrared.

  14. Water-cooled probe technique for the study of freeze lining formation

    NASA Astrophysics Data System (ADS)

    Verscheure, Karel; Campforts, Mieke; Verhaeghe, Frederik; Boydens, Eddy; Blanpain, Bart; Wollants, Patrick; van Camp, Maurits

    2006-12-01

    Furnace protection by water-cooled freeze linings becomes increasingly important as the metal producing industry attempts to achieve higher process intensities. Systematic investigations of the growth and the resulting microstructure and compositional profile of freeze linings are necessary to understand the behavior of freeze linings, their relation with the industrial process, and their interaction with the wall cooling system. We have developed a technique based on the submergence of a water-cooled probe into a liquid slag bath. Freeze linings of two industrial nonferrous slags have been produced using this technique and their growth, microstructural, and compositional profiles as a function of submergence time were determined. Thermodynamic equilibrium for the investigated slag systems was calculated and compared with the observed microstructures. The freeze linings form in approximately 15 minutes. Close to the water cooling, the freeze linings are predominantly amorphous in structure. With increasing distance from the water cooling, the proportion of crystalline phases increases and bath material is entrapped in the microstructure. Cellular crystals are observed close to the bath. The freeze linings exhibit an approximate homogeneous composition. The results demonstrate that the technique is a successful tool in obtaining information on the growth, microstructure, and composition of freeze linings in industrial water-cooled furnaces.

  15. Effects of climatic seasonality on the isotopic composition of evaporating soil waters

    NASA Astrophysics Data System (ADS)

    Benettin, Paolo; Volkmann, Till H. M.; von Freyberg, Jana; Frentress, Jay; Penna, Daniele; Dawson, Todd E.; Kirchner, James W.

    2018-05-01

    Stable water isotopes are widely used in ecohydrology to trace the transport, storage, and mixing of water on its journey through landscapes and ecosystems. Evaporation leaves a characteristic signature on the isotopic composition of the water that is left behind, such that in dual-isotope space, evaporated waters plot below the local meteoric water line (LMWL) that characterizes precipitation. Soil and xylem water samples can often plot below the LMWL as well, suggesting that they have also been influenced by evaporation. These soil and xylem water samples frequently plot along linear trends in dual-isotope space. These trend lines are often termed "evaporation lines" and their intersection with the LMWL is often interpreted as the isotopic composition of the precipitation source water. Here we use numerical experiments based on established isotope fractionation theory to show that these trend lines are often by-products of the seasonality in evaporative fractionation and in the isotopic composition of precipitation. Thus, they are often not true evaporation lines, and, if interpreted as such, can yield highly biased estimates of the isotopic composition of the source water.

  16. Testing and use of radar water level sensors by the U.S. Geological Survey

    USGS Publications Warehouse

    Fulford, Janice M.

    2016-01-01

    The United States Geological Survey uses water-level (or stage) measurements to compute streamflow at over 8000 stream gaging stations located throughout the United States (waterwatch.usgs.gov, 2016). Streamflow (or discharge) is computed at five minute to hourly intervals from a relationship between water level and discharge that is uniquely determined for each station. The discharges are posted hourly to WaterWatch (waterwatch. usgs.gov) and are used by water managers to issue flood warnings and manage water supply and by other users of water information to make decisions. The accuracy of the water-level measurement is vital to the accuracy of the computed discharge. Because of the importance of water-level measurements, USGS has an accuracy policy of 0.02 ft or 0.2 percent of reading (whichever is larger) (Sauer and Turnipseed, 2010). Older technologies, such as float and shaft-encoder systems, bubbler systems and submersible pressure sensors, provide the needed accuracy but often require extensive construction to install and are prone to malfunctioning and damage from floating debris and sediment. No stilling wells or orifice lines need to be constructed for radar installations. During the last decade testing by the USGS Hydrologic Instrumentation Facility(HIF) found that radar water-level sensors can provide the needed accuracy for water-level measurements and because the sensor can be easily attached to bridges, reduce the construction required for installation. Additionally, the non-contact sensing of water level minimizes or eliminates damage and fouling from floating debris and sediment. This article is a brief summary of the testing efforts by the USGS HIF and field experiences with models of radar water-level sensors in streamflow measurement applications. Any use of trade names in this article is for descriptive purposes only and does not imply endorsement by the U.S. Government.

  17. Sublimation in bright spots on (1) Ceres.

    PubMed

    Nathues, A; Hoffmann, M; Schaefer, M; Le Corre, L; Reddy, V; Platz, T; Cloutis, E A; Christensen, U; Kneissl, T; Li, J-Y; Mengel, K; Schmedemann, N; Schaefer, T; Russell, C T; Applin, D M; Buczkowski, D L; Izawa, M R M; Keller, H U; O'Brien, D P; Pieters, C M; Raymond, C A; Ripken, J; Schenk, P M; Schmidt, B E; Sierks, H; Sykes, M V; Thangjam, G S; Vincent, J-B

    2015-12-10

    The dwarf planet (1) Ceres, the largest object in the main asteroid belt with a mean diameter of about 950 kilometres, is located at a mean distance from the Sun of about 2.8 astronomical units (one astronomical unit is the Earth-Sun distance). Thermal evolution models suggest that it is a differentiated body with potential geological activity. Unlike on the icy satellites of Jupiter and Saturn, where tidal forces are responsible for spewing briny water into space, no tidal forces are acting on Ceres. In the absence of such forces, most objects in the main asteroid belt are expected to be geologically inert. The recent discovery of water vapour absorption near Ceres and previous detection of bound water and OH near and on Ceres (refs 5-7) have raised interest in the possible presence of surface ice. Here we report the presence of localized bright areas on Ceres from an orbiting imager. These unusual areas are consistent with hydrated magnesium sulfates mixed with dark background material, although other compositions are possible. Of particular interest is a bright pit on the floor of crater Occator that exhibits probable sublimation of water ice, producing haze clouds inside the crater that appear and disappear with a diurnal rhythm. Slow-moving condensed-ice or dust particles may explain this haze. We conclude that Ceres must have accreted material from beyond the 'snow line', which is the distance from the Sun at which water molecules condense.

  18. Effect of water turbidity on the visual acuity of harbor seals (Phoca vitulina).

    PubMed

    Weiffen, Michael; Möller, Bettina; Mauck, Björn; Dehnhardt, Guido

    2006-05-01

    The underwater visual acuity (the angle subtended by the minimal resolvable line width of high contrast square wave gratings at a viewing distance of 2m) of two male harbor seals was determined at different levels of water turbidity. Starting with visual acuity angles of 5.5' and 12.7' in clear water we found visual acuity to decrease rapidly with increasing turbidity at rates of 7.4' and 6.0' per formazin nephelometric unit (FNU). Besides the individual differences in visual performance of the harbor seals tested, our results reveal a dramatic loss of visual acuity even at moderate levels of turbidity. At sites in the German Wadden Sea, where harbor seals are known to roam and forage, we measured turbidity levels exceeding 40FNU. These data suggest that turbidity has to be considered as an important factor in the sensory ecology of pinnipeds.

  19. Coordinating Numeric and Linear Units: Elementary Students' Strategies for Locating Whole Numbers on the Number Line

    ERIC Educational Resources Information Center

    Saxe, Geoffrey B.; Shaughnessy, Meghan M.; Gearhart, Maryl; Haldar, Lina Chopra

    2013-01-01

    Two investigations of fifth graders' strategies for locating whole numbers on number lines revealed patterns in students' coordination of numeric and linear units. In Study 1, we investigated the effects of context on students' placements of three numbers on an open number line. For one group ("n"?=?24), the line was presented in a…

  20. Drinking water contaminants from epoxy resin-coated pipes: A field study.

    PubMed

    Rajasärkkä, Johanna; Pernica, Marek; Kuta, Jan; Lašňák, Jonáš; Šimek, Zdenĕk; Bláha, Luděk

    2016-10-15

    Rehabilitation of aged drinking water pipes is an extensive renovation and increasingly topical in many European cities. Spray-on-lining of drinking water pipes is an alternative cost-effective rehabilitation technology in which the insides of pipes are relined with organic polymer. A commonly used polymer is epoxy resin consisting of monomer bisphenol A (BPA). Leaching of BPA from epoxy lining to drinking water has been a concern among public and authorities. Currently epoxy lining is not recommended in some countries. BPA leaching has been demonstrated in laboratory studies but the behavior and ageing process of epoxy lining in situ is not well known. In this study 6 locations with different age epoxy linings of drinking water pipes done using two distinct technologies were studied. While bisphenol F, 4-n-nonylphenol, and 4-t-octylphenol were rarely found and in trace concentrations, BPA was detected in majority of samples. Pipes lined with the older technology (LSE) leached more BPA than those with more recent technology (DonPro): maxima in cold water were 0.25 μg/L and 10 ng/L, respectively. Incubation of water in pipes 8-10 h prior to sampling increased BPA concentration in cold water 1.1-43-fold. Hot water temperature caused even more BPA leaching - at maximum 23.5 μg/L. The influence of ageing of epoxy lining on BPA leaching on could be shown in case of LSE technology: locations with 8-9 years old lining leached 4-20-fold more BPA compared to a location with 2-year-old lining. Analysis of metals showed that epoxy lining can reduce especially iron concentration in water. No significant burden to water could be shown by the analyzed 72 volatile organic compounds, including epichlorhydrin, precursor used in epoxy resin. Estrogenicity was detected in water samples with the highest BPA loads. Comparable responses of two yeast bioreporters (estrogen receptor α and BPA-targeted) indicated that bisphenol-like compounds were the main cause of estrogenicity. Compared to the estimated average daily BPA exposure, additional BPA load via cold drinking water in the studied locations was low, maximum 8.7%. However, hot water should also be considered as exposure source due to higher BPA concentrations. Epoxy lined locations should be monitored in future in order to evaluate ageing process and control increasing leaching of potentially harmful chemicals. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. Pollution Prevention in the Land Maintenance System

    DTIC Science & Technology

    2000-04-01

    pollutants, and greenhouse gases. Canada’s Land Maintenance System consists of first line field units, second line field units, base units and a repair...workshops. For example, extending maintenance schedules, using extended life products and using dehumidification for preservation of equipment will lower

  2. Rapid Shifts in Oxygen and Hydrogen Isotopes, and Chemical Components in Pore Waters During mid-Oligocene in Sediments from IODP 351drilling

    NASA Astrophysics Data System (ADS)

    Zhang, Z.

    2017-12-01

    A total of 65 pore water samples were obtained from a sediment sequence in the Amami-Sankaku Basin during the IODP 351 Expedition, which consists of a 160 m thick section of terrestrial origin and underlying 1.3 km thick volcaniclastic section sampled at site U1438. Downcore variations of chemical compositions are characterized by increasing salinity/pH, increasing concentrations of Cl and Ca, and decreasing concentrations of Mg, K and Na, as well as decreasing d18O and dD. The rapid changes in those chemical components and isotopic composition occurred deeper than the lithology boundary between Unit III and Unit II, most likely as a result of substantial difference in extent of alteration above and below this boundary. The strong alterations of volcanicalstic minerals below the boundary not only result in diminishment of K, Mg, Si, and Mn, and an increase of Ca and Cl, but also depleted d18O in pore water. However, hydrogen fractionation factors between pore water and secondary minerals are less 1, and depleted dD values in pore water most likely reflect the signal of paleo-seawater. As a result, samples below the boundary are all plotted on the left side of the meteorite water line (MWL) on the dD vs. d18O plot. Above the boundary, they are placed to the right side of MWL due to substantially weakened alteration, reflecting an evolving trend in sediment setting from the predominance of alterated volcaniclasts to terrestrial pelagic sediments.

  3. WATER QUALITY AND TREATMENT CONSIDERATIONS FOR CEMENT-LINED AND A-C PIPE

    EPA Science Inventory

    Both cement mortar lined (CML) and asbestos-cement pipes (A-C) are widely used in many water systems. Cement linings are also commonly applied in-situ after pipe cleaning, usually to prevent the recurrence of red water or tuberculation problems. Unfortunately, little consideratio...

  4. Nanosilver as a disinfectant in dental unit waterlines ...

    EPA Pesticide Factsheets

    Dental unit water lines (DUWL) are susceptible to biofilm development and bacterial growth leading to water contamination, causing health and ecological effects. This study monitors the interactions between a commonly used nanosilver disinfectant (ASAP-AGX-32, an antimicrobial cleaner for dental units, 0.0032% Ag) and biofilm development in DUWL. To simulate the disinfection scenario, an in-house DUWL model was assembled and biofilm accumulation was allowed. Subsequent to biofilm development, the disinfection process was performed according to the manufacturer's instructions. The pristine nanosilver particles in the cleaner measured between 3 and 5 nm in diameter and were surrounded by a stabilizing polymer. However, the polymeric stabilizing agent diminished over the disinfection process, initiating partial AgNPs aggregation. Furthermore, surface speciation of the pristine AgNPs were identified as primarily AgO, and after the disinfection process, transformations to AgCl were observed. The physicochemical characteristics of AgNPs are known to govern their fate, and transport and environmental implications. Hence, knowledge of the AgNPs characteristics after the disinfection process (usage scenario) is of significance. This study demonstrates the adsorption of AgNPs onto biofilm surfaces and, therefore, will assist in illustration of the toxicity mechanisms of AgNPs to bacteria and biofilms. This work can be an initial step in better understanding how

  5. Helicopter Electromagnetic and Magnetic Geophysical Survey Data for Portions of the North Platte River and Lodgepole Creek, Nebraska, June 2008

    USGS Publications Warehouse

    Smith, Bruce D.; Abraham, Jared D.; Cannia, James C.; Hill, Patricia

    2009-01-01

    This report is a release of digital data from a helicopter electromagnetic and magnetic survey that was conducted during June 2008 in areas of western Nebraska as part of a joint hydrologic study by the North Platte Natural Resource District, South Platte Natural Resource District, and U.S. Geological Survey. The objective of the contracted survey, conducted by Fugro Airborne, Ltd., was to improve the understanding of the relationship between surface water and groundwater systems critical to developing groundwater models used in management programs for water resources. The survey covered 1,375 line km (854 line mi). A unique aspect of this survey is the flight line layout. One set of flight lines were flown paralleling each side of the east-west trending North Platte River and Lodgepole Creek. The survey also included widely separated (10 km) perpendicular north-south lines. The success of this survey design depended on a well understood regional hydrogeologic framework and model developed by the Cooperative Hydrologic Study of the Platte River Basin. Resistivity variations along lines could be related to this framework. In addition to these lines, more traditional surveys consisting of parallel flight lines separated by about 270 m were carried out for one block in each of the drainages. These surveys helped to establish the spatial variations of the resistivity of hydrostratigraphic units. The electromagnetic equipment consisted of six different coil-pair orientations that measured resistivity at separated frequencies from about 400 Hz to about 140,000 Hz. The electromagnetic data along flight lines were converted to electrical resistivity. The resulting line data were converted to geo-referenced grids and maps which are included with this report. In addition to the electromagnetic data, total field magnetic data and digital elevation data were collected. Data released in this report consist of data along flight lines, digital grids, and digital maps of the apparent resistivity and total magnetic field. The depth range of the subsurface investigation for the electromagnetic survey (estimated as deep as 60 m) is comparable to the depth of shallow aquifers. The geophysical data and hydrologic information from U.S. Geological Survey and cooperator studies are being used by resource managers to develop groundwater resource plans for the area. In addition, data will be used to refine hydrologic models in western Nebraska.

  6. The Impact of Supplementary On-Line Resources on Academic Performance: A Study of First-Year University Students Studying Economics

    ERIC Educational Resources Information Center

    Birch, Elisa; Williams, Andrew

    2013-01-01

    This paper examines the impact of supplementary web-based materials on students' academic performance in a first-year economics unit at university. In particular, the paper considers the impact of students' usage of the unit's webpage, voluntary on-line discussion board, voluntary on-line quizzes and voluntary on-line homework questions on their…

  7. Conducting Qualitative Data Analysis: Reading Line-by-Line, but Analyzing by Meaningful Qualitative Units

    ERIC Educational Resources Information Center

    Chenail, Ronald J.

    2012-01-01

    In the first of a series of "how-to" essays on conducting qualitative data analysis, Ron Chenail points out the challenges of determining units to analyze qualitatively when dealing with text. He acknowledges that although we may read a document word-by-word or line-by-line, we need to adjust our focus when processing the text for purposes of…

  8. Microbial contamination of dental unit waterlines: short- and long-term effects of flushing.

    PubMed

    Santiago, J I; Huntington, M K; Johnston, A M; Quinn, R S; Williams, J F

    1994-01-01

    The extensive microbial contamination of DUW in this study is consistent with that described in previous reports. Comparisons with other common public potable water sources emphasize the relatively high concentrations of microorganisms in DUW, and the low numbers of bacteria in most domestic water samples. Microscopic evidence of amebas and worms in DUW reinforces the need for further qualitative and quantitative studies of these contaminants of dental tubing biofilm. In most cases, flushing for two minutes reduced microbial concentrations in DUW. However, in a few cases, concentrations rose; in others, the reductions were negligible. Moreover, after 30 minutes of stasis, or use of the waterline in a routine dental procedure, microbial counts were frequently restored to preflush levels or higher. The longer-term ineffectiveness 30 minutes after flushing is understandable when the hydrodynamics of laminar flow of water in narrow-bore tubing are considered. Biofilm on the tubing wall remains intact during flushes and quickly generates more bacteria during stasis. Increased bacterial concentrations after flushing probably result from sloughing of biofilm from the tubing wall because of stretching and movement of the line during routine use. These two phenomena undermine the benefits of routine water flushes. It is a common belief that bacterial levels build to extremes during overnight or weekend stasis; we observed more variation in contamination levels during the workday than between overnight stasis and typical workday samples. The presence of hemolytic staphylococci and streptococci in water samples from lines that were supplied only from sterile water reservoirs adds to the growing evidence that part of the microbial flora in DUWLs may be derived from patients' mouths. Additional prophylactic measures to limit bacterial contamination in DUW should be implemented according to standard principles used in other medical fluid delivery devices.

  9. On-line monitoring of the photocatalytic degradation of 2,4-D and dicamba using a solid-phase extraction-multisyringe flow injection system.

    PubMed

    Chávez-Moreno, Carmín; Ferrer, Laura; Hinojosa-Reyes, Laura; Hernández-Ramírez, Aracely; Cerdà, Víctor; Guzmán-Mar, Jorge

    2013-11-15

    A fully automated on-line system for monitoring the photocatalytic degradation of herbicides was developed using multisyringe flow injection analysis (MSFIA) coupled to a solid phase extraction (SPE) unit with UV detection. The calibration curves were linear in the concentration range of 100-1000 μg L(-1) for 3,6-dichloro-2-methoxybenzoic acid (dicamba) and 500-3000 μg L(-1) for 2,4-dichlorophenoxyacetic acid (2,4-D), while the detection limits were 30 and 135 μg L(-1) for dicamba and 2,4-D, respectively. The monitoring of the photocatalytic degradation (TiO2 anatase/UV 254 nm) of these two herbicides was performed by MSFIA-SPE system using a small sample volume (2 mL) in a fully automated approach. The degradation was assessed in ultrapure and drinking water with initial concentrations of 1000 and 2000 μg L(-1) for dicamba and 2,4-D, respectively. Degradation percentages of approximately 85% were obtained for both herbicides in ultrapure water after 45 min of photocatalytic treatment. A similar degradation efficiency in drinking water was observed for 2,4-D, whereas dicamba exhibited a lower degradation percentage (75%), which could be attributed to the presence of inorganic species in this kind of water. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Water level observations in mangrove swamps during two hurricanes in Florida

    USGS Publications Warehouse

    Krauss, K.W.; Doyle, T.W.; Doyle, T.J.; Swarzenski, C.M.; From, A.S.; Day, Richard H.; Conner, W.H.

    2009-01-01

    Little is known about the effectiveness of mangroves in suppressing water level heights during landfall of tropical storms and hurricanes. Recent hurricane strikes along the Gulf Coast of the United States have impacted wetland integrity in some areas and hastened the need to understand how and to what degree coastal forested wetlands confer protection by reducing the height of peak water level. In recent years, U.S. Geological Survey Gulf Coast research projects in Florida have instrumented mangrove sites with continuous water level recorders. Our ad hoc network of water level recorders documented the rise, peak, and fall of water levels (?? 0.5 hr) from two hurricane events in 2004 and 2005. Reduction of peak water level heights from relatively in-line gages associated with one storm surge event indicated that mangrove wetlands can reduce water level height by as much as 9.4 cm/km inland over intact, relatively unchannelized expanses. During the other event, reductions were slightly less for mangroves along a river corridor. Estimates of water level attenuation were within the range reported in the literature but erred on the conservative side. These synoptic data from single storm events indicate that intact mangroves may support a protective role in reducing maximum water level height associated with surge.

  11. The Sensitivity of West African Squall Line Water Budgets to Land Cover

    NASA Technical Reports Server (NTRS)

    Mohr, Karen I.; Baker, R. David; Tao, Wei-Kuo; Famiglietti, James S.; Starr, David OC. (Technical Monitor)

    2001-01-01

    This study used a two-dimensional coupled land/atmosphere (cloud-resolving) model to investigate the influence of land cover on the water budgets of squall lines in the Sahel. Study simulations used the same initial sounding and one of three different land covers, a sparsely vegetated semi-desert, a grassy savanna, and a dense evergreen broadleaf forest. All simulations began at midnight and ran for 24 hours to capture a full diurnal cycle. In the morning, the latent heat flux, boundary layer mixing ratio, and moist static energy in the boundary layer exhibited notable variations among the three land covers. The broadleaf forest had the highest latent heat flux, the shallowest, moistest, slowest growing boundary layer, and significantly more moist static energy per unit area than the savanna and semi-desert. Although all simulations produced squall lines by early afternoon, the broadleaf forest had the most intense, longest-lived squall lines with 29% more rainfall than the savanna and 37% more than the semi-desert. The sensitivity of the results to vegetation density, initial sounding humidity, and grid resolution was also assessed. There were greater differences in rainfall among land cover types than among simulations of the same land cover with varying amounts of vegetation. Small changes in humidity were equivalent in effect to large changes in land cover, producing large changes in the condensate and rainfall. Decreasing the humidity had a greater effect on rainfall volume than increasing the humidity. Reducing the grid resolution from 1.5 km to 0.5 km decreased the temperature and humidity of the cold pools and increased the rain volume.

  12. Bedrock aquifers of eastern San Juan County, Utah

    USGS Publications Warehouse

    Avery, Charles

    1986-01-01

    This study is one of a series of studies appraising the waterbearing properties of the Navajo Sandstone and associated formations in southern Utah.  The stu<¥ area is al:x>dy area is about 4,600 square miles, extending from the Utah-Arizona State line northward to the San Juan-Grand County line and westward from the Utah-Colorado State line to the longitude of about 109°50'.Some of the water-yielding formations are grouped into aquifer systems. The C aquifer is comprised of the DeChelly Sandstone Member of the Cutler Formation.  The P aquifer is comprised of the Cedar Mesa Member of the Cutler Formation and the undifferentiated Cutler Formation. The N aquifer is comprised of the sedimentary section that includes the Wingate Sandstone, Kayenta Formation, Navajo Sandstone, Carmel Formation, and Entrada sandstone.  The M aquifer is comprised of the Bluff Sandstone Member and other sandstone units of the Morrison Formation.  The D aquifer is comprised of the Burro Canyon Formation and Dakota Sandstone.  Discharge from the ground-water reservoir to the San Juan River between gaging stations at Four Corners and Mexican Hat is about 66 cubic feet per second.The N aquifer is the main aquifer in the study area. Recharge by infiltration of precipitation is estimated to be 25,000 acre-feet per year.  A major ground-water divide exists under the broad area east of Monticello.  The thickness of the N aquifer, where the sedimentary section is fully preserved and saturated, generally is 750 to 1,250 feet.   Hydraulic conductivity values obtained from aquifer tests range from 0.02 to 0.34 foot per day.  The total volume of water in transient storage is about 11 million acre-feet. Well discharge somewhat exceeded 2,340 acre-feet during 1981.  Discharge to the San Juan River from the N aquifer is estimated to be 6.9 cubic feet per second. Water quality ranges from a calcium bicarbonate to sodium chloride type water

  13. Water Environment Assessment as an Ecological Red Line Management Tool for Marine Wetland Protection.

    PubMed

    Zhang, Yinan; Chu, Chunli; Liu, Lei; Xu, Shengguo; Ruan, Xiaoxue; Ju, Meiting

    2017-08-02

    A 'red line' was established, identifying an area requiring for ecological protection in Tianjin, China. Within the protected area of the red line area, the Qilihai wetland is an important ecotope with complex ecological functions, although the ecosystem is seriously disturbed due to anthropogenic activities in the surrounding areas. This study assesses the water quality status of the Qilihai wetlands to identify the pollution sources and potential improvements based on the ecological red line policy, to improve and protect the waters of the Qilihai wetlands. An indicator system was established to assess water quality status using single factor evaluation and a comprehensive evaluation method, supported by data from 2010 to 2013. Assessment results show that not all indicators met the requirement of the Environmental Quality Standards for Surface Water (GB3838-2002) and that overall, waters in the Qilihai wetland were seriously polluted. Based on these findings we propose restrictions on all polluting anthropogenic activities in the red line area and implementation of restoration projects to improve water quality.

  14. Application of uphole data from petroleum seismic surveys to groundwater investigations, Abu Dhabi (United Arab Emirates)

    USGS Publications Warehouse

    Woodward, D.; Menges, C.M.

    1991-01-01

    Velocity data from uphole surveys were used to map the water table and the contact at the base dune sand/top alluvium as part of a joint National Drilling Company-United States Geological Survey Ground Water Research Project in the Emirate of Abu Dhabi. During 1981-1983, a reconnaissance seismic survey was conducted for petroleum exploration in the eastern region of Abu Dhabi. Approximately 2800 kilometers of seismic data, consisting of 92 lines, were acquired in the 2500 km2 concession area near Al Ain. Uphole surveys were conducted about 2 km apart along each seismic line, and were used to calculate weathering corrections required to further process in the seismic data. Approximately 1300 uphole surveys were completed in the concession area between March 1981 and June 1983. Reinterpretation of the velocity profiles derived from the uphole surveys provided data for determining the following subsurface layers, listed in descending order: (1) a surficial, unconsolidated weathering layer with a velocity from 300 to 450 m/s; (2) surficial dune sand, from 750 to 900 m/s; (3) unsaturated, unconsolidated alluvium, from 1000 to 1300 m/s; and (4) saturated, unconsolidated alluvium, from 1900 to 2200 m/s. Two interfaces-the water table and the base dune sand/top alluvium - were identified and mapped from boundaries between these velocity layers. Although the regional water table can fluctuate naturally as much as 3 m per year in this area and the water-table determinations from the uphole data span a 27-month period, an extremely consistent and interpretable water-table map was derived from the uphole data throughout the entire concession area. In the northern part of the area, unconfined groundwater moves northward and northwestward toward the Arabian Gulf; and in the central and southern parts of the area, groundwater moves westward away from the Oman Mountains. In the extreme southern area east of Jabal Hafit, groundwater moves southward into Oman. The map of the base dune sand/top alluvium suggests a buried paleodrainage network trending westward to southwestward away from the Oman Mountains. These paleodrainages, now buried by dune sand, probably contain alluvial fill and are logical targets for groundwater exploration. ?? 1991.

  15. A multi-wavelength database of water vapor in planet-forming regions

    NASA Astrophysics Data System (ADS)

    Pontoppidan, Klaus

    The inner few astronomical units of gas-rich protoplanetary disk are environments characterized by a rich and active gaseous chemistry. Primitive material left over from the formation of our own Solar System has for a long time yielded tantalizing clues to a heterogenous nebula with intricate dynamical, thermal and chemical structure that ultimately led to a great diversity in the planets and planetesimals of the Solar System. The discovery of a rich chemistry in protoplanetary disks via a forest of strong 3-40 micron molecular emission lines (H2O, OH, CO2, HCN, C2H2,...) allows us for the first time to investigate chemical diversity in other planet-forming environmments (Salyk et al. 2008; Carr & Najita 2008). Further efforts, supported by the Origins program, has established that this molecular forest is seen in the disks surrounding most young solar- type stars (Pontoppidan et al. 2010). We propose a 3-year program to analyze our growing multi-wavelength database of observations of water, OH and organic molecules in the surfaces of protoplanetary disks. The database includes high (R~25,000-100,000) and medium resolution (R~600-3000) 3- 200 micron spectra from a wide range of facilities (Keck-NIRSPEC, VLT-CRIRES, Spitzer-IRS, VLT-VISIR, Gemini-Michelle and Herschel-PACS). Our previous efforts have focused on demonstrating feasibility for observing water and other molecules in planet-forming regions, building statistics to show that the molecular forest is ubiquitous in disks around low-mass and solar-type stars and taking the first steps in understanding the implied chemical abundances. Now, as the next logical step, we will combine multi- wavelength data from our unique multi-wavelength database to map the radial distribution of, in particular, water and its derivatives. 1) We will use both line profile information from the high-resolution spectra, as well as line strengths, from a combination of high and low temperature lines to constrain the radial abundance of water vapor in the emitting surfaces of disks. Despite high water abundances inside ~1 AU, there is evidence that the disk surfaces are strongly depleted in water both from the gas and ice phases, by as much as 6 orders of magnitude, beyond 1-2 AU. This may be due to the settling of icy grains as part of the formation of icy planetesimals (Meijerink et al. 2009; Bergin et al. 2010). We wish to quantify the depletion factor and establish whether this is a common property of all protoplanetary disks. 2) We will pursue critical new datasets using upcoming observational facilities, including spectrally resolved rotational water lines in the mid-infrared. VLT-VISIR, with which we have successfully detected water lines at high resolution, is undergoing a significant hardware upgrade with a planned commissioning around January 2012. The upgrade includes a much larger and more sensitive detector based on technology developed for JWST-MIRI, which is expected to increase its efficiency by 1-2 orders of magnitude. On a longer time scale, SOFIA-EXES, JWST-NIRSpec and MIRI will become essential instruments for moving this field forward. Pontoppidan is a JWST-NIRSpec instrument scientist at STScI. 3) We will search for variability of water lines on time scales of months and compare them to variation already seen in CO gas to investigate its origin. One intriguing possibility is dynamical interaction with protoplanets. The proposed research is highly relevant for the Origins of Solar Systems program as described in the solicitation document. It falls into the categories dealing with "Observations related to understanding the formation and evolution of planetary systems" and "Studies of chemical processes related to the formation of planetary systems."

  16. A multi-wavelength database of water vapor in planet-forming regions

    NASA Astrophysics Data System (ADS)

    Pontoppidan, Klaus

    The inner few astronomical units of gas-rich protoplanetary disk are environments characterized by a rich and active gaseous chemistry. Primitive material left over from the formation of our own Solar System has for a long time yielded tantalizing clues to a heterogenous nebula with intricate dynamical, thermal and chemical structure that ultimately led to a great diversity in the planets and planetesimals of the Solar System. The discovery of a rich chemistry in protoplanetary disks via a forest of strong 3-40 micron molecular emission lines (H2O, OH, CO2, HCN, C2H2,...) allows us for the first time to investigate chemical diversity in other planet-forming environmments (Salyk et al. 2008; Carr & Najita 2008). Further efforts, supported by the Origins program, has established that this molecular forest is seen in the disks surrounding most young solar- type stars (Pontoppidan et al. 2010). We propose a 3-year program to analyze our growing multi-wavelength database of observations of water, OH and organic molecules in the surfaces of protoplanetary disks. The database includes high (R~25,000-100,000) and medium resolution (R~600-3000) 3- 200 micron spectra from a wide range of facilities (Keck-NIRSPEC, VLT-CRIRES, Spitzer-IRS, VLT-VISIR, Gemini-Michelle and Herschel-PACS). Our previous efforts have focused on demonstrating feasibility for observing water and other molecules in planet-forming regions, building statistics to show that the molecular forest is ubiquitous in disks around low-mass and solar-type stars and taking the first steps in understanding the implied chemical abundances. Now, as the next logical step, we will combine multi- wavelength data from our unique multi-wavelength database to map the radial distribution of, in particular, water and its derivatives. 1) Â We will use both line profile information from the high-resolution spectra, as well as line strengths, from a combination of high and low temperature lines to constrain the radial abundance of water vapor in the emitting surfaces of disks. Despite high water abundances inside ~1 AU, there is evidence that the disk surfaces are strongly depleted in water both from the gas and ice phases, by as much as 6 orders of magnitude, beyond 1-2 AU. This may be due to the settling of icy grains as part of the formation of icy planetesimals (Meijerink et al. 2009; Bergin et al. 2010). We wish to quantify the depletion factor and establish whether this is a common property of all protoplanetary disks. 2) Â We will pursue critical new datasets using upcoming observational facilities, including spectrally resolved rotational water lines in the mid-infrared. VLT-VISIR, with which we have successfully detected water lines at high resolution, is undergoing a significant hardware upgrade with a planned commissioning around January 2012. The upgrade includes a much larger and more sensitive detector based on technology developed for JWST-MIRI, which is expected to increase its efficiency by 1-2 orders of magnitude. On a longer time scale, SOFIA-EXES, JWST-NIRSpec and MIRI will become essential instruments for moving this field forward. Pontoppidan is a JWST-NIRSpec instrument scientist at STScI. 3) Â We will search for variability of water lines on time scales of months and compare them to variation already seen in CO gas to investigate its origin. One intriguing possibility is dynamical interaction with protoplanets. The proposed research is highly relevant for the Origins of Solar Systems program as described in the solicitation document. It falls into the categories dealing with "Observations related to understanding the formation and evolution of planetary systems" and "Studies of chemical processes related to the formation of planetary systems."

  17. Water in Betelgeuse and Antares

    NASA Technical Reports Server (NTRS)

    Jennings, D. E.; Sada, P. V.

    1998-01-01

    Absorption lines of hot water have been identified in the infrared spectra of Betelgeuse (alpha Orionis) and Antares (alpha Scorpii) near 12.3 micrometers (811 to 819 wavenumbers). The water lines originate in the atmospheres of the stars, not in their circumstellar material. The spectra are similar in structure to umbral sunspot spectra. Pure rotation water lines of this type will occur throughout the spectra of cool stars at wavelengths greater than 10 micrometers. From the water spectra, the upper limit for the temperature in the line formation region in both stars is 2800 kelvin. The water column density in both stars is (3 +/- 2) x 10(18) molecules per square centimeter, yielding an abundance relative to atomic hydrogen of n(H2O)/n(H) approximately 10(-)7.

  18. Hydrogeologic framework of the North Carolina Coastal Plain aquifer system

    USGS Publications Warehouse

    Winner, M.D.; Coble, R.W.

    1989-01-01

    The hydrogeologic framework of the North Carolina Coastal Plain aquifer system consists of ten aquifers separated by nine confining units. From top to bottom the aquifers are: the surficial aquifer, Yorktown aquifer, Pungo River aquifer, Castle Hayne aquifer, Beaufort aquifer, Peedee aquifer, Black Creek aquifer, upper Cape Fear aquifer, lower Cape Fear aquifer, and the Lower Cretaceous aquifer. The uppermost aquifer (the surficial aquifer in most places) is a water-table aquifer and the bottom of the system is underlain by crystalline bedrock. The sedimentary deposits forming the aquifers are of Holocene to Cretaceous age and are composed mostly of sand with lesser amounts of gravel and limestone. Confining units between aquifers are composed primarily of clay and silt. The thickness of the aquifers ranges from zero along the Fall Line to more than 10,000 feet at Cape Hatteras. Prominent structural features are the increasing easterly homoclinal dip of the sediments and the Cape Fear arch, the axis of which trends in a southeast direction. The stratigraphic continuity is determined from correlations of 161 geophysical logs along with data from drillers' and geologists' logs. Aquifers were defined by means of these logs plus water-level and water-quality data and evidence of the continuity of pumping effects. Eighteen hydrogeologic sections depict the correlation of these aquifers throughout the Coastal Plain.

  19. An Exploration of Administrative Heuristics in the United States and the United Kingdom

    ERIC Educational Resources Information Center

    English, Fenwick W.; Bolton, Cheryl L.

    2008-01-01

    This article is a report on a study of the use of heuristics, shortcuts, and rules of thumb by middle-line managers in institutions of higher education in the United States and the United Kingdom. Using a nonprobability convenience sample, the coinvestigators interviewed 13 middle-line managers over 5 months from eight institutions. The results…

  20. Elicitors and defense gene induction in plants with altered lignin compositions.

    PubMed

    Gallego-Giraldo, Lina; Posé, Sara; Pattathil, Sivakumar; Peralta, Angelo Gabriel; Hahn, Michael G; Ayre, Brian G; Sunuwar, Janak; Hernandez, Jonathan; Patel, Monika; Shah, Jyoti; Rao, Xiaolan; Knox, J Paul; Dixon, Richard A

    2018-06-27

    A reduction in the lignin content in transgenic plants induces the ectopic expression of defense genes, but the importance of altered lignin composition in such phenomena remains unclear. Two Arabidopsis lines with similar lignin contents, but strikingly different lignin compositions, exhibited different quantitative and qualitative transcriptional responses. Plants with lignin composed primarily of guaiacyl units overexpressed genes responsive to oomycete and bacterial pathogen attack, whereas plants with lignin composed primarily of syringyl units expressed a far greater number of defense genes, including some associated with cis-jasmone-mediated responses to aphids; these plants exhibited altered responsiveness to bacterial and aphid inoculation. Several of the defense genes were differentially induced by water-soluble extracts from cell walls of plants of the two lines. Glycome profiling, fractionation and enzymatic digestion studies indicated that the different lignin compositions led to differential extractability of a range of heterogeneous oligosaccharide epitopes, with elicitor activity originating from different cell wall polymers. Alteration of lignin composition affects interactions with plant cell wall matrix polysaccharides to alter the sequestration of multiple latent defense signal molecules with an impact on biotic stress responses. © 2018 The Authors. New Phytologist © 2018 New Phytologist Trust.

  1. 78 FR 27126 - East Bay, St. Andrews Bay and the Gulf of Mexico at Tyndall Air Force Base, Florida; Restricted...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-09

    ... a line connecting the following coordinates: Commencing from the mean high water line at... defined at 33 CFR part 329 within the area bounded by a line connecting the following coordinates... bounded by a line connecting the following coordinates: Commencing from the mean high water line at...

  2. Groundwater conditions and studies in the Augusta–Richmond County area, Georgia, 2008–2009

    USGS Publications Warehouse

    Gonthier, Gerard; Lawrence, Stephen J.; Peck, Michael F.; Holloway, O. Gary

    2011-01-01

    Groundwater studies and monitoring efforts conducted during 2008–2009, as part of the U.S. Geological Survey (USGS) Cooperative Water Program with the City of Augusta in Richmond County, Georgia, provided data for the effective management of local water resources. During 2008–2009 the USGS completed: (1) installation of three monitoring wells and the collection of lithologic and geophysical logging data to determine the extent of hydrogeologic units, (2) collection of continuous groundwater-level data from wells near Well Fields 2 and 3, (3) collection of synoptic groundwater-level measurements and construction of potentiometric-surface maps in Richmond County to establish flow gradients and groundwater-flow directions in the Dublin and Midville aquifer systems, (4) completion of a 24-hour aquifer test to determine hydraulic characteristics of the lower Dublin aquifer, and upper and lower Midville aquifers in Well Field 2, and (5) collection of groundwater samples from selected wells in Well Field 2 for laboratory analysis of volatile organic compounds and groundwater tracers to assess groundwater quality and estimate the time of groundwater recharge. Potentiometric-surface maps of the Dublin and Midville aquifer systems for 2008–2009 indicate that the general groundwater flow direction within Richmond County is eastward toward the Savannah River, with the exception of the area around Well Field 2, where pumping interrupts the eastward flow of water toward the Savannah River and causes flow lines to bend toward the center of pumping. Results from a 24-hour aquifer test conducted in 2009 within the upper and lower Midville aquifers at Well Field 2 indicated a transmissivity and storativity for the upper and lower Midville aquifers, combined, of 4,000 feet-squared per day and 2x10-4, respectively. The upper and lower Midville aquifers and the middle lower Midville confining unit, which is 85-feet thick in this area, yielded horizontal hydraulic conductivity and specific storage values of about 45 feet per day and 2x10-6 ft-1, respectively. Results from the 24-hour aquifer test also indicate a low horizontal hydraulic conductivity for the lower Dublin aquifer of less than 1 foot per day. Of the 35 volatile organic compounds (VOCs) analyzed in 23 groundwater samples during 2008–2009, only six were detected above laboratory reporting limits in samples from eight wells. No concentration in groundwater samples collected during 2008–2009 exceeded drinking water standards. Trichloroethene had the maximum VOC concentration (1.9 micrograms per liter) collected from a water sample during 2008–2009. Water-quality sampling of several wells near Well Field 2 indicate that, while in operation, the northernmost production well might have diverted groundwater, containing low levels of trichloroethene from at least two other production wells. Analysis of sulfur hexafluoride data indicate the average year of recharge ranges between 1981 and 1984 for water samples from five wells open to the upper and lower Midville aquifers, and 1991 for a water sample from one shallow well open to the lower Dublin aquifer. All of these ages suggest a short flow path and nearby source of contamination. The actual source of low levels of VOCs at Well Field 2 remains unknown. Three newly installed monitoring wells indicate that hydrogeologic units beneath Well Fields 2 and 3 are composed of sand and clay layers. Hydrogeologic units, encountered at Well Field 2, in order of increasing depth are the lower Dublin confining unit, lower Dublin aquifer, upper Midville confining unit, upper Midville aquifer, lower Midville confining unit, and lower Midville aquifer. West of Well Field 3, hydrogeologic units, in order of increasing depth are the Upper Three Runs aquifer, Gordon confining unit, Gordon aquifer, lower Dublin confining unit, lower Dublin aquifer, upper Midville confining unit, upper Midville aquifer, lower Midville confining unit, and lower Midville aquifer.

  3. Use of Six Sigma strategies to pull the line on central line-associated bloodstream infections in a neurotrauma intensive care unit.

    PubMed

    Loftus, Kelli; Tilley, Terry; Hoffman, Jason; Bradburn, Eric; Harvey, Ellen

    2015-01-01

    The creation of a consistent culture of safety and quality in an intensive care unit is challenging. We applied the Six Sigma Define-Measure-Analyze-Improve-Control (DMAIC) model for quality improvement (QI) to develop a long-term solution to improve outcomes in a high-risk neurotrauma intensive care unit. We sought to reduce central line utilization as a cornerstone in preventing central line-associated bloodstream infections (CLABSIs). This study describes the successful application of the DMAIC model in the creation and implementation of evidence-based quality improvement designed to reduce CLABSIs to below national benchmarks.

  4. Water line positions in the 782-840 nm region

    NASA Astrophysics Data System (ADS)

    Hu, S.-M.; Chen, B.; Tan, Y.; Wang, J.; Cheng, C.-F.; Liu, A.-W.

    2015-10-01

    A set of water transitions in the 782-840 nm region, including 38 H216O lines, 12 HD16O lines, and 30 D216O lines, were recorded with a cavity ring-down spectrometer calibrated using precise atomic lines. Absolute frequencies of the lines were determined with an accuracy of about 5 MHz. Systematic shifts were found in the line positions given in the HITRAN database and the upper energy levels given in recent MARVEL studies.

  5. Geochemistry of formation waters from the Wolfcamp and “Cline” shales: Insights into brine origin, reservoir connectivity, and fluid flow in the Permian Basin, USA

    USGS Publications Warehouse

    Engle, Mark A.; Reyes, Francisco R.; Varonka, Matthew S.; Orem, William H.; Lin, Ma; Ianno, Adam J.; Westphal, Tiffani M.; Xu, Pei; Carroll, Kenneth C.

    2016-01-01

    Despite being one of the most important oil producing provinces in the United States, information on basinal hydrogeology and fluid flow in the Permian Basin of Texas and New Mexico is lacking. The source and geochemistry of brines from the basin were investigated (Ordovician- to Guadalupian-age reservoirs) by combining previously published data from conventional reservoirs with geochemical results for 39 new produced water samples, with a focus on those from shales. Salinity of the Ca–Cl-type brines in the basin generally increases with depth reaching a maximum in Devonian (median = 154 g/L) reservoirs, followed by decreases in salinity in the Silurian (median = 77 g/L) and Ordovician (median = 70 g/L) reservoirs. Isotopic data for B, O, H, and Sr and ion chemistry indicate three major types of water. Lower salinity fluids (<70 g/L) of meteoric origin in the middle and upper Permian hydrocarbon reservoirs (1.2–2.5 km depth; Guadalupian and Leonardian age) likely represent meteoric waters that infiltrated through and dissolved halite and anhydrite in the overlying evaporite layer. Saline (>100 g/L), isotopically heavy (O and H) water in Leonardian [Permian] to Pennsylvanian reservoirs (2–3.2 km depth) is evaporated, Late Permian seawater. Water from the Permian Wolfcamp and Pennsylvanian “Cline” shales, which are isotopically similar but lower in salinity and enriched in alkalis, appear to have developed their composition due to post-illitization diffusion into the shales. Samples from the “Cline” shale are further enriched with NH4, Br, I and isotopically light B, sourced from the breakdown of marine kerogen in the unit. Lower salinity waters (<100 g/L) in Devonian and deeper reservoirs (>3 km depth), which plot near the modern local meteoric water line, are distinct from the water in overlying reservoirs. We propose that these deep meteoric waters are part of a newly identified hydrogeologic unit: the Deep Basin Meteoric Aquifer System. Chemical, isotopic, and pressure data suggest that despite over-pressuring in the Wolfcamp shale, there is little potential for vertical fluid migration to the surface environment via natural conduits.

  6. Water Planetary and Cometary Atmospheres: H2O/HDO Transmittance and Fluorescence Models

    NASA Technical Reports Server (NTRS)

    Villanueva, G. L.; Mumma, M. J.; Bonev, B. P.; Novak, R. E.; Barber, R. J.; DiSanti, M. A.

    2012-01-01

    We developed a modern methodology to retrieve water (H2O) and deuterated water (HDO) in planetary and cometary atmospheres, and constructed an accurate spectral database that combines theoretical and empirical results. Based on a greatly expanded set of spectroscopic parameters, we built a full non-resonance cascade fluorescence model and computed fluorescence efficiencies for H2O (500 million lines) and HDO (700 million lines). The new line list was also integrated into an advanced terrestrial radiative transfer code (LBLRTM) and adapted to the CO2 rich atmosphere of Mars, for which we adopted the complex Robert-Bonamy formalism for line shapes. We then retrieved water and D/H in the atmospheres of Mars, comet C/2007 WI, and Earth by applying the new formalism to spectra obtained with the high-resolution spectrograph NIRSPEC/Keck II atop Mauna Kea (Hawaii). The new model accurately describes the complex morphology of the water bands and greatly increases the accuracy of the retrieved abundances (and the D/H ratio in water) with respect to previously available models. The new model provides improved agreement of predicted and measured intensities for many H2O lines already identified in comets, and it identifies several unassigned cometary emission lines as new emission lines of H2O. The improved spectral accuracy permits retrieval of more accurate rotational temperatures and production rates for cometary water.

  7. 50 CFR 660.399 - EFH Conservation Areas off the Coast of California.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... The boundary of the Harris Point EFH Conservation Area is defined by the mean high water line and... commercial and recreational take of living marine resources is allowed, exists between the mean high water... Scorpion EFH Conservation Area is defined by the mean high water line and a straight line connecting all of...

  8. 50 CFR 660.79 - EFH Conservation Areas off the Coast of California.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    .... The boundary of the Harris Point EFH Conservation Area is defined by the mean high water line and... commercial and recreational take of living marine resources is allowed, exists between the mean high water... Scorpion EFH Conservation Area is defined by the mean high water line and a straight line connecting all of...

  9. Antimicrobial Effect of An Essential Oil Blend on Surface-attached Salmonella on Polyvinyl Chloride

    USDA-ARS?s Scientific Manuscript database

    The majority of drinking water lines for broilers are made of polyvinyl chloride (PVC) and surface attachment of Salmonella on the inner surface of water lines can be the initial stage of biofilm development. These biofilms can be the source of Salmonella infection in water lines and are known to re...

  10. Effects of solvent concentration and composition on protein dynamics: 13C MAS NMR studies of elastin in glycerol-water mixtures.

    PubMed

    Demuth, Dominik; Haase, Nils; Malzacher, Daniel; Vogel, Michael

    2015-08-01

    We use (13)C CP MAS NMR to investigate the dependence of elastin dynamics on the concentration and composition of the solvent at various temperatures. For elastin in pure glycerol, line-shape analysis shows that larger-scale fluctuations of the protein backbone require a minimum glycerol concentration of ~0.6 g/g at ambient temperature, while smaller-scale fluctuations are activated at lower solvation levels of ~0.2 g/g. Immersing elastin in various glycerol-water mixtures, we observe at room temperature that the protein mobility is higher for lower glycerol fractions in the solvent and, thus, lower solvent viscosity. When decreasing the temperature, the elastin spectra approach the line shape for the rigid protein at 245 K for all studied samples, indicating that the protein ceases to be mobile on the experimental time scale of ~10(-5) s. Our findings yield evidence for a strong coupling between elastin fluctuations and solvent dynamics and, hence, such interaction is not restricted to the case of protein-water mixtures. Spectral resolution of different carbon species reveals that the protein-solvent couplings can, however, be different for side chain and backbone units. We discuss these results against the background of the slaving model for protein dynamics. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. a Novel Method for Automation of 3d Hydro Break Line Generation from LIDAR Data Using Matlab

    NASA Astrophysics Data System (ADS)

    Toscano, G. J.; Gopalam, U.; Devarajan, V.

    2013-08-01

    Water body detection is necessary to generate hydro break lines, which are in turn useful in creating deliverables such as TINs, contours, DEMs from LiDAR data. Hydro flattening follows the detection and delineation of water bodies (lakes, rivers, ponds, reservoirs, streams etc.) with hydro break lines. Manual hydro break line generation is time consuming and expensive. Accuracy and processing time depend on the number of vertices marked for delineation of break lines. Automation with minimal human intervention is desired for this operation. This paper proposes using a novel histogram analysis of LiDAR elevation data and LiDAR intensity data to automatically detect water bodies. Detection of water bodies using elevation information was verified by checking against LiDAR intensity data since the spectral reflectance of water bodies is very small compared with that of land and vegetation in near infra-red wavelength range. Detection of water bodies using LiDAR intensity data was also verified by checking against LiDAR elevation data. False detections were removed using morphological operations and 3D break lines were generated. Finally, a comparison of automatically generated break lines with their semi-automated/manual counterparts was performed to assess the accuracy of the proposed method and the results were discussed.

  12. Influence of Miles City Line 1 on the United States Hereford Population

    USDA-ARS?s Scientific Manuscript database

    The goal of this research was to document the influence of Line 1 (L1) Hereford cattle developed by the United States Department of Agriculture at its research facility in Miles City, Montana, on the United States Hereford population. The L1 Hereford population originated in 1934 and has been therea...

  13. Arabian Sea as seen from STS-62

    NASA Technical Reports Server (NTRS)

    1994-01-01

    The photo depicts many of the types of ocean features seen when illuminated by sunglint. These features include a shear line, bilge dump, currents, and ship wakes. Winds, currents and oils effect the smoothness of the surface of the water. The oils smooth the water which reflect the sun more than the rougher surrounding water. This is seen in the bright curved line which is a bilge dump of oily water from a ship. The oils then start to take the form of the currents and in this case are also being blown by the surface winds. The shear line is approximately 240 miles west of Bombay, India. This shear line appears to be a result of two water masses, moving at slightly different speeds, having converged. Ship wakes, such as those in the photo, which cross a shear line, often give us an indication of the relative strength of a shear.

  14. A water vapour monitor at Paranal Observatory

    NASA Astrophysics Data System (ADS)

    Kerber, Florian; Rose, Thomas; Chacón, Arlette; Cuevas, Omar; Czekala, Harald; Hanuschik, Reinhard; Momany, Yazan; Navarrete, Julio; Querel, Richard R.; Smette, Alain; van den Ancker, Mario E.; Cure, Michel; Naylor, David A.

    2012-09-01

    We present the performance characteristics of a water vapour monitor that has been permanently deployed at ESO's Paranal observatory as a part of the VISIR upgrade project. After a careful analysis of the requirements and an open call for tender, the Low Humidity and Temperature Profiling microwave radiometer (LHATPRO), manufactured by Radiometer Physics GmbH (RPG), has been selected. The unit measures several channels across the strong water vapour emission line at 183 GHz, necessary for resolving the low levels of precipitable water vapour (PWV) that are prevalent on Paranal (median ~2.5 mm). The unit comprises the above humidity profiler (183-191 GHz), a temperature profiler (51-58 GHz), and an infrared radiometer (~10 μm) for cloud detection. The instrument has been commissioned during a 2.5 week period in Oct/Nov 2011, by comparing its measurements of PWV and atmospheric profiles with the ones obtained by 22 radiosonde balloons. In parallel an IR radiometer (Univ. Lethbridge) has been operated, and various observations with ESO facility spectrographs have been taken. The RPG radiometer has been validated across the range 0.5 - 9 mm demonstrating an accuracy of better than 0.1 mm. The saturation limit of the radiometer is about 20 mm. Currently, the radiometer is being integrated into the Paranal infrastructure to serve as a high time-resolution monitor in support of VLT science operations. The water vapour radiometer's ability to provide high precision, high time resolution information on this important aspect of the atmosphere will be most useful for conducting IR observations with the VLT under optimal conditions.

  15. Effects of Land Use Land Cover (LULC) and Climate on Simulation of Phosphorus loading in the Southeast United States Region

    NASA Astrophysics Data System (ADS)

    Jima, T. G.; Roberts, A.

    2013-12-01

    Quality of coastal and freshwater resources in the Southeastern United States is threatened due to Eutrophication as a result of excessive nutrients, and phosphorus is acknowledged as one of the major limiting nutrients. In areas with much non-point source (NPS) pollution, land use land cover and climate have been found to have significant impact on water quality. Landscape metrics applied in catchment and riparian stream based nutrient export models are known to significantly improve nutrient prediction. The regional SPARROW (Spatially Referenced Regression On Watershed attributes), which predicts Total Phosphorus has been developed by the Southeastern United States regions USGS, as part of the National Water Quality Assessment (NAWQA) program and the model accuracy was found to be 67%. However, landscape composition and configuration metrics which play a significant role in the source, transport and delivery of the nutrient have not been incorporated in the model. Including these matrices in the models parameterization will improve the models accuracy and improve decision making process for mitigating and managing NPS phosphorus in the region. The National Land Cover Data 2001 raster data will be used (since the base line is 2002) for the region (with 8321 watersheds ) with fragstats 4.1 and ArcGIS Desktop 10.1 for the analysis of landscape matrices, buffers and creating map layers. The result will be imported to the Southeast SPARROW model and will be analyzed. Resulting statistical significance and model accuracy will be assessed and predictions for those areas with no water quality monitoring station will be made.

  16. Optical monitor for water vapor concentration

    DOEpatents

    Kebabian, Paul

    1998-01-01

    A system for measuring and monitoring water vapor concentration in a sample uses as a light source an argon discharge lamp, which inherently emits light with a spectral line that is close to a water vapor absorption line. In a preferred embodiment, the argon line is split by a magnetic field parallel to the direction of light propagation from the lamp into sets of components of downshifted and upshifted frequencies of approximately 1575 Gauss. The downshifted components are centered on a water vapor absorption line and are thus readily absorbed by water vapor in the sample; the upshifted components are moved away from that absorption line and are minimally absorbed. A polarization modulator alternately selects the upshifted components or downshifted components and passes the selected components to the sample. After transmission through the sample, the transmitted intensity of a component of the argon line varies as a result of absorption by the water vapor. The system then determines the concentration of water vapor in the sample based on differences in the transmitted intensity between the two sets of components. In alternative embodiments alternate selection of sets of components is achieved by selectively reversing the polarity of the magnetic field or by selectively supplying the magnetic field to the emitting plasma.

  17. Optical monitor for water vapor concentration

    DOEpatents

    Kebabian, P.

    1998-06-02

    A system for measuring and monitoring water vapor concentration in a sample uses as a light source an argon discharge lamp, which inherently emits light with a spectral line that is close to a water vapor absorption line. In a preferred embodiment, the argon line is split by a magnetic field parallel to the direction of light propagation from the lamp into sets of components of downshifted and upshifted frequencies of approximately 1575 Gauss. The downshifted components are centered on a water vapor absorption line and are thus readily absorbed by water vapor in the sample; the upshifted components are moved away from that absorption line and are minimally absorbed. A polarization modulator alternately selects the upshifted components or downshifted components and passes the selected components to the sample. After transmission through the sample, the transmitted intensity of a component of the argon line varies as a result of absorption by the water vapor. The system then determines the concentration of water vapor in the sample based on differences in the transmitted intensity between the two sets of components. In alternative embodiments alternate selection of sets of components is achieved by selectively reversing the polarity of the magnetic field or by selectively supplying the magnetic field to the emitting plasma. 5 figs.

  18. Eight-Year Summary of Fort Irwin, CA, Family Housing Comparison Test: Operation and Maintenance Costs of Manufactured vs. Conventionally Built Units

    DTIC Science & Technology

    1993-07-01

    Ruptured polybutylene pipe from Building 3858, Unit C 77 F20 Longitudinal hair line crack in PB pipe from Building 3802, Unit B 78 F21 Microscopic...of the 200 housing units used national standards in the unit construction which included the use of polybutylene ( PB ) piping. The piping was...in PB Pipe from Building 3802, Unit B Figure F 21: Microscopic View of Longitudinal Hair Line Crack 78 Figure F22: White Coating on Acetld Fitting

  19. Peach Bottom Atomic Power Station recirc pipe dose rates with zinc injection and condenser replacement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DiCello, D.C.; Odell, A.D.; Jackson, T.J.

    1995-03-01

    Peach Bottom Atomic Power Station (PBAPS) is located near the town of Delta, Pennsylvania, on the west bank of the Susquehanna River. It is situated approximately 20 miles south of Lancaster, Pennsylvania. The site contains two boiling water reactors of General Electric design and each rated at 3,293 megawatts thermal. The units are BWR 4s and went commercial in 1977. There is also a decommissioned high temperature gas-cooled reactor on site, Unit 1. PBAPS Unit 2 recirc pipe was replaced in 1985 and Unit 3 recirc pipes replaced in 1988 with 326 NGSS. The Unit 2 replacement pipe was electropolished,more » and the Unit 3 pipe was electropolished and passivated. The Unit 2 brass condenser was replaced with a Titanium condenser in the first quarter of 1991, and the Unit 3 condenser was replaced in the fourth quarter of 1991. The admiralty brass condensers were the source of natural zinc in both units. Zinc injection was initiated in Unit 2 in May 1991, and in Unit 3 in May 1992. Contact dose rate measurements were made in standard locations on the 28-inch recirc suction and discharge lines to determine the effectiveness of zinc injection and to monitor radiation build-up in the pipe. Additionally, HPGe gamma scans were performed to determine the isotopic composition of the oxide layer inside the pipe. In particular, the specific ({mu}Ci/cm{sup 2}) of Co-60 and Zn-65 were analyzed.« less

  20. Thermal bubble inkjet printing of water-based graphene oxide and graphene inks on heated substrate

    NASA Astrophysics Data System (ADS)

    Huang, Simin; Shen, Ruoxi; Qian, Bo; Li, Lingying; Wang, Wenhao; Lin, Guanghui; Zhang, Xiaofei; Li, Peng; Xie, Yonglin

    2018-04-01

    Stable-jetting water-based graphene oxide (GO) and graphene (GR) inks without any surfactant or stabilizer are prepared from an unstable-jetting water-based starting solvent, with many thermal bubble inkjet satellite drops, by simply increasing the material concentration. The concentration-dependent thermal bubble inkjet droplet generation process is studied in detail. To overcome the low concentration properties of water-based thermal bubble inkjet inks, the substrate temperature is tuned below 60 °C to achieve high-quality print lines. Due to the difference in hydrophilicity and hydrophobicity of the 2D materials, the printed GO lines show a different forming mechanism from that of the GR lines. The printed GO lines are reduced by thermal annealing and by ascorbic acid, respectively. The reduced GO lines exhibit electrical conductivity of the same order of magnitude as that of the GR lines.

  1. Role of aquifer heterogeneity in fresh groundwater discharge and seawater recycling: An example from the Carmel coast, Israel

    USGS Publications Warehouse

    Weinstein, Y.; Burnett, W.C.; Swarzenski, P.W.; Shalem, Y.; Yechieli, Y.; Herut, B.

    2007-01-01

    A case study is shown in which the pattern of submarine groundwater discharge and of seawater recycling is controlled by local hydrogeological variability. The coastal aquifer in Dor Bay is composed of two units: a partly confined calcaranitic sandstone (Kurkar) and an overlying loose sand. Groundwater in the Kurkar has elevated activities of 222Rn (∼390 dpm/L) and relatively low 224Ra/223Ra activity ratios (3–4), while the sand groundwater is significantly less radiogenic (6–90 dpm/L) and shows higher 224Ra/223Ra ratios. Groundwater discharging from sand-covered areas of the bay has salinities of 16–31 and an average 222Rn activity of 168 dpm/L, which lies on a mixing line between Rn-rich Kurkar fresh water and Rn-poor seawater. Another key observation is that seawater infiltrates to some extent into onshore sand groundwater, while the fresh water within the submarine Kurkar can be traced up to 40 m offshore. This implies that while fresh water mainly discharges from the Kurkar unit, seawater recycling is limited to the loose sand, and that the discharge from sand-covered areas is a mixture of Kurkar water with recycled seawater. Advection rates from the bay floor were calculated from Rn time series and found to vary between 0 and 36 cm/d, correlating negatively with bay water depth. The average flux was 8.1 cm/d, and it did not seem to change much during March, May, and July 2006. The average amount of fresh water discharging to the bay was 5.0 m3/d per meter of shoreline. Radon activity in the sand groundwater also fluctuates due to influx of Kurkar-type groundwater.

  2. 33 CFR 110.197 - Galveston Harbor, Bolivar Roads Channel, Texas.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Roads Channel, Texas. (a)(1) Anchorage area (A). The water bounded by a line connecting the following... water bounded by a line connecting the following points: Latitude Longtitude 29°20′43.0″ N 94°44′46.5″ W... point of beginning. (3) Anchorage area (C). The water bounded by a line connecting the following points...

  3. 33 CFR 110.197 - Galveston Harbor, Bolivar Roads Channel, Texas.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Roads Channel, Texas. (a)(1) Anchorage area (A). The water bounded by a line connecting the following... water bounded by a line connecting the following points: Latitude Longtitude 29°20′43.0″ N 94°44′46.5″ W... point of beginning. (3) Anchorage area (C). The water bounded by a line connecting the following points...

  4. Hydrogeologic and hydrochemical framework, south-central Great Basin, Nevada-California, with special reference to the Nevada Test Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Winograd, I.J.; Thordarson, W.

    Intensely fractured Precambrian and Paleozoic carbonate and clastic rocks and block-faulted Cenozoic volcanic and sedimentary strata in the Nevada Test Site are divided into 10 hydrogeologic units. Three of these--the lower clastic aquitard, the lower carbonate aquifer, and the tuff aquitard--control the regional movement of ground water. The coefficients of fracture transmissiblity of these rocks are, respectively, less than 1,000, 1,000 to 900,000, and less than 200 gallons per day per foot; interstitial permeability is negligible. Solution caverns are locally present in the carbonate aquifer, but regional movement of water is controlled by variations in fracture transmissibility and by structuralmore » juxtaposition of the aquifer and the lower clastic aquitard. Water circulates freely to depths of at least 1,500 feet beneath the top of the aquifer and up to 4,200 feet below land surface. Synthesis of hydrogeologic, hydrochemical, and isotopic data suggests that an area of at least 4,500 square miles (including 10 intermontane valleys) is hydraulically integrated into one ground-water basin, the Ash Meadows basin, by interbasin movement of ground water through the widespread carbonate aquifer. Discharge from this basin--a minimum of about 17,000 acre-feet annually--occurs along a fault-controlled spring line at Ash Meadows in east-central Amargosa Desert. Intrabasin movement of water between Cenozoic aquifers and the lower carbonate aquifer is controlled by the tuff aquitard, the basal Cenozoic hydrogeologic unit. Such movement significantly influences the chemistry of water in the carbonate aquifer. Ground-water velocity through the tuff aquitard in Yucca Flat is less than 1 foot per year. Velocity through the lower carbonate aquifer ranges from an estimated 0.02 to 200 feet per day, depending upon geographic position within the flow system.Within the Nevada Test Site, ground water moves southward and southwestward toward Ash Meadows.« less

  5. Sensory aspects of drinking water in contact with epoxy lined copper pipe.

    PubMed

    Heim, T H; Dietrich, A M

    2007-01-01

    Pipe relining via in situ epoxy lining is used to remediate corroded plumbing or distribution systems. This investigation examined the effects on odour, TOC, THM formation and disinfectant demand in water exposed to epoxy-lined copper pipes used for home plumbing. The study was conducted in accordance with the Utility Quick Test, a migration/leaching method for utilities to conduct sensory analysis of materials in contact with drinking water. The test was performed using water with no disinfectant and levels of chlorine and monochloramines representative of those found in the distribution system. Panelists repeatedly and consistently described a "plastic/adhesive/putty" odour in the water from the pipes. The odour intensity remained relatively constant for each of two subsequent flushes. Water samples stored in the epoxy-lined pipes showed a significant increase in the leaching of organic compounds (as TOC), and this TOC was demonstrated to react with free chlorine to form trichloromethane. Water stored in the pipes also showed a marked increase in disinfectant demand relative to the water stored in glass control flasks. A study conducted at a full scale installation at an apartment demonstrated that after installation and regular use, the epoxy lining did not yield detectable differences in water quality.

  6. Development of a salt drug with improved solubility: Ethionamide nitrate

    NASA Astrophysics Data System (ADS)

    Diniz, Luan F.; Carvalho, Paulo S.; de Melo, Cristiane C.; Ellena, Javier

    2017-06-01

    To avoid drug resistance, an adequate tuberculosis treatment should include not only a first-line drug but also at least one second-line drug such as, for example, Ethionamide (ETH). However, the dissolution rate and oral absorption of ETH is highly limited by its low aqueous solubility. Considering that a salt is in general more soluble than its parent compound, herein we depicted a new supramolecular modification of ETH, an Ethionamide nitrate salt (ETHNO3). This salt is the first ETH structure that has been crystallized with four independent ionic pairs (ETH+NO3-) in the asymmetric unit. In addition to the structural study, the salt formation was also identified on the FT-IR and FT-Raman spectra. The thermal behavior of ETHNO3 was also investigated here together with its solubility profile in three dissolution media (purified water, pH 4.0 and 7.0).

  7. Manufacturing Enhancement through Reduction of Cycle Time using Different Lean Techniques

    NASA Astrophysics Data System (ADS)

    Suganthini Rekha, R.; Periyasamy, P.; Nallusamy, S.

    2017-08-01

    In recent manufacturing system the most important parameters in production line are work in process, TAKT time and line balancing. In this article lean tools and techniques were implemented to reduce the cycle time. The aim is to enhance the productivity of the water pump pipe by identifying the bottleneck stations and non value added activities. From the initial time study the bottleneck processes were identified and then necessary expanding processes were also identified for the bottleneck process. Subsequently the improvement actions have been established and implemented using different lean tools like value stream mapping, 5S and line balancing. The current state value stream mapping was developed to describe the existing status and to identify various problem areas. 5S was used to implement the steps to reduce the process cycle time and unnecessary movements of man and material. The improvement activities were implemented with required suggested and the future state value stream mapping was developed. From the results it was concluded that the total cycle time was reduced about 290.41 seconds and the customer demand has been increased about 760 units.

  8. N. plumbaginifolia zeaxanthin epoxidase transgenic lines have unaltered baseline ABA accumulations in roots and xylem sap, but contrasting sensitivities of ABA accumulation to water deficit.

    PubMed

    Borel, C; Audran, C; Frey, A; Marion-Poll, A; Tardieu, F; Simonneau, T

    2001-03-01

    A series of transgenic lines of Nicotiana plumbaginifolia with modified expression of zeaxanthin epoxidase gene (ZEP) provided contrasting ABA accumulation in roots and xylem sap. For mild water stress, concentration of ABA in the xylem sap ([ABA](xylem)) was clearly lower in plants underexpressing ZEP mRNA (complemented mutants and antisense transgenic lines) than in wild-type. In well-watered conditions, all lines presented similar [ABA](xylem) and similar ABA accumulation rates in detached roots. Plants could, therefore, be grown under normal light intensities and evaporative demand. Both ZEP mRNA abundance and ABA accumulation rate in roots increased with water deficit in all transgenic lines, except in complemented aba2-s1 mutants in which the ZEP gene was controlled by a constitutive promoter which does not respond to water deficit. These lines presented no change in root ABA content either with time or dehydration. The increase in ZEP mRNA abundance in roots with decreasing RWC was more pronounced in detached roots than in whole plants, suggesting a difference in mechanism. In all transgenic lines, a linear relationship was observed between predawn leaf water potential and [ABA](xylem), which could be reproduced in several experiments in the greenhouse and in the growth chamber. It is therefore possible to represent the effect of the transformation by a single parameter, thereby allowing the use of a quantitative approach to assist understanding of the behaviour of transgenic lines.

  9. Physiological basis of genetic variation in leaf photosynthesis among rice (Oryza sativa L.) introgression lines under drought and well-watered conditions

    PubMed Central

    Yin, Xinyou

    2012-01-01

    To understand the physiological basis of genetic variation and resulting quantitative trait loci (QTLs) for photosynthesis in a rice (Oryza sativa L.) introgression line population, 13 lines were studied under drought and well-watered conditions, at flowering and grain filling. Simultaneous gas exchange and chlorophyll fluorescence measurements were conducted at various levels of incident irradiance and ambient CO2 to estimate parameters of a model that dissects photosynthesis into stomatal conductance (g s), mesophyll conductance (g m), electron transport capacity (J max), and Rubisco carboxylation capacity (V cmax). Significant genetic variation in these parameters was found, although drought and leaf age accounted for larger proportions of the total variation. Genetic variation in light-saturated photosynthesis and transpiration efficiency (TE) were mainly associated with variation in g s and g m. One previously mapped major QTL of photosynthesis was associated with variation in g s and g m, but also in J max and V cmax at flowering. Thus, g s and g m, which were demonstrated in the literature to be responsible for environmental variation in photosynthesis, were found also to be associated with genetic variation in photosynthesis. Furthermore, relationships between these parameters and leaf nitrogen or dry matter per unit area, which were previously found across environmental treatments, were shown to be valid for variation across genotypes. Finally, the extent to which photosynthesis rate and TE can be improved was evaluated. Virtual ideotypes were estimated to have 17.0% higher photosynthesis and 25.1% higher TE compared with the best genotype investigated. This analysis using introgression lines highlights possibilities of improving both photosynthesis and TE within the same genetic background. PMID:22888131

  10. Geochemical and Sr isotopic variations in groundwaters of the Edwards aquifer, central Texas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oetting, G.C.; Banner, J.L.; Sharp, J.M. Jr.

    1992-01-01

    The regionally-extensive Edwards aquifer of central Texas lies on the northwestern edge of the Gulf of Mexico Basin. The aquifer system is composed primarily of lower Cretaceous marine limestones and dolostones with minor evaporitic and siliciclastic confining units of the Edwards Group and associated formations. The eastern and southern boundaries of the freshwater aquifer are defined by an abrupt change in groundwater salinity that is known as the badwater line. Variation in the isotopic composition and concentration of Sr in the mineral phases and waters in this aquifer system provide means to examine groundwater evolution processes. Models of simultaneous variationsmore » in Sr isotopes and major and trace ions are used to constrain processes of groundwater-rock interaction and groundwater mixing. Geochemical variations were examined in Edwards carbonate host rocks and groundwaters in Williamson and Bell Counties. Groundwaters were sampled along and across the badwater line, and range in salinity from 320--2,630 mg/l total dissolved solids. Major ion distributions in the water samples demonstrate a hydrochemical facies transition from Ca-HCO[sub 3] freshwaters to Na-Cl-SO[sub 4]-HCO[sub 3] badwaters. Both water types show a wide range of [sup 87]Sr/[sup 86]Sr values: Ca-HCO[sub 3] waters range from values of 0.7078--0.7093, and Na-Cl-SO[sub 4]-HCO[sub 3] waters range from values of 0.7087--0.7097. The Sr isotope compositions for both water groups are significantly greater than their host marine carbonates ([approximately]0.7075). The high Sr isotopic compositions indicate an extraformational source of Sr in both hydrochemical facies. Fluid mixing processes involving a freshwater and at least two badwater endmembers are required to account for variations in elemental and isotopic compositions in the groundwaters. Mineral-solution reactions may operate during and/or subsequent to mixing to produce the compositional variability observed in some intermediate waters.« less

  11. International Towing Tank Conference ITTC Symbols and Terminology List. Final Version 1996

    DTIC Science & Technology

    1997-05-13

    law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB...of water-plane aft of mWA midship 2 A AWF Area of water-plane forward mWF of midship 2 A AX Area of maximum transverse mX section 2 B B Beam or...design water line B BWL Maximum moulded breadth mWL at design water line B BX Breadth, moulded of mX maximum section area at design water line d,T T

  12. Geohydrologic units and water-level conditions in the Terrace alluvial aquifer and Paluxy Aquifer, May 1993 and February 1994, near Air Force Plant 4, Fort Worth area, Texas

    USGS Publications Warehouse

    Rivers, Glen A.; Baker, Ernest T.; Coplin, L.S.

    1996-01-01

    The terrace alluvial aquifer underlying Air Force Plant 4 and the adjacent Naval Air Station (formerly Carswell Air Force Base) in the Fort Worth area, Texas, is contaminated locally with organic and metal compounds. Residents south and west of Air Force Plant 4 and the Naval Air Station are concerned that contaminants might enter the underlying Paluxy aquifer, which provides water to the city of White Settlement, south of Air Force Plant 4, and to residents west of Air Force Plant 4. The U.S. Environmental Protection Agency has qualified Air Force Plant 4 for Superfund cleanup. The pertinent geologic units include -A~rom oldest to youngest the Glen Rose, Paluxy, and Walnut Formations, Goodland Limestone, and terrace alluvial deposits. Except for the Glen Rose Formation, all units crop out at or near Air Force Plant 4 and the Naval Air Station. The terrace alluvial deposits, which nearly everywhere form the land surface, range from 0 to about 60 feet thick. These deposits comprise a mostly unconsolidated mixture of gravel, sand, silt, and clay. Mudstone and sandstone of the Paluxy Formation crop out north, west, and southwest of Lake Worth and total between about 130 and about 175 feet thick. The terrace alluvial deposits and the Paluxy Formation comprise the terrace alluvial aquifer and the Paluxy aquifer, respectively. These aquifers are separated by the Goodland-Walnut confining unit, composed of the Goodland Limestone and (or) Walnut Formation. Below the Paluxy aquifer, the Glen Rose Formation forms the Glen Rose confining unit. Water-level measurements during May 1993 and February 1994 from wells in the terrace alluvial aquifer indicate that, regionally, ground water flows toward the east-southeast beneath Air Force Plant 4 and the Naval Air Station. Locally, water appears to flow outward from ground-water mounds maintained by the localized infiltration of precipitation and reportedly by leaking water pipes and sanitary and (or) storm sewer lines beneath the assembly building at Air Force Plant 4. North of Farmers Branch, the terrace alluvial aquifer discharges into Lake Worth, Meandering Road Creek, Farmers Branch, and the West Fork Trinity River. South of Farmers Branch, ground water appears to flow mostly north-northeastward. Greater precipitation prior to the May 1993 measurements caused water levels to average approximately 5 ft higher in May 1993 than in February 1994. Regional ground-water gradients indicate west to east-southeastward flow in the Paluxy aquifer, with a dominant southeastward component beneath Air Force Plant 4. Water-level maps for the Paluxy "upper sand" reveal an elongated groundwater mound beneath southeastern parts of Air Force Plant 4, which indicates a localized, vertical conduit through which contaminated water from the terrace alluvial aquifer might enter upper parts of the Paluxy aquifer. The Paluxy "upper sand" apparently is mostly unsaturated and hydraulically separated from the deeper, regionally extensive parts of the Paluxy aquifer, most of which are fully saturated. While water levels in the "upper sand" were as much as 10 ft higher in May 1993 than in February 1994, water levels in most deeper parts of the Paluxy aquifer were slightly higher in February 1994 than they were in May 1993.

  13. Digital Bedrock Compilation: A Geodatabase Covering Forest Service Lands in California

    NASA Astrophysics Data System (ADS)

    Elder, D.; de La Fuente, J. A.; Reichert, M.

    2010-12-01

    This digital database contains bedrock geologic mapping for Forest Service lands within California. This compilation began in 2004 and the first version was completed in 2005. Second publication of this geodatabase was completed in 2010 and filled major gaps in the southern Sierra Nevada and Modoc/Medicine Lake/Warner Mountains areas. This digital map database was compiled from previously published and unpublished geologic mapping, with source mapping and review from California Geological Survey, the U.S. Geological Survey and others. Much of the source data was itself compilation mapping. This geodatabase is huge, containing ~107,000 polygons and ~ 280,000 arcs. Mapping was compiled from more than one thousand individual sources and covers over 41,000,000 acres (~166,000 km2). It was compiled from source maps at various scales - from ~ 1:4,000 to 1:250,000 and represents the best available geologic mapping at largest scale possible. An estimated 70-80% of the source information was digitized from geologic mapping at 1:62,500 scale or better. Forest Service ACT2 Enterprise Team compiled the bedrock mapping and developed a geodatabase to store this information. This geodatabase supports feature classes for polygons (e.g, map units), lines (e.g., contacts, boundaries, faults and structural lines) and points (e.g., orientation data, structural symbology). Lookup tables provide detailed information for feature class items. Lookup/type tables contain legal values and hierarchical groupings for geologic ages and lithologies. Type tables link coded values with descriptions for line and point attributes, such as line type, line location and point type. This digital mapping is at the core of many quantitative analyses and derivative map products. Queries of the database are used to produce maps and to quantify rock types of interest. These include the following: (1) ultramafic rocks - where hazards from naturally occurring asbestos are high, (2) granitic rocks - increased erosion hazards, (3) limestone, chert, sedimentary rocks - paleontological resources (Potential Fossil Yield Classification maps), (4) calcareous rocks (cave resources, water chemistry), and (5) lava flows - lava tubes (more caves). Map unit groupings (e.g., belts, terranes, tectonic & geomorphic provinces) can also be derived from the geodatabase. Digital geologic mapping was used in ground water modeling to predict effects of tunneling through the San Bernardino Mountains. Bedrock mapping is used in models that characterize watershed sediment regimes and quantify anthropogenic influences. When combined with digital geomorphology mapping, this geodatabase helps to assess landslide hazards.

  14. REFLECTOR CONTROL OF A BOILING-WATER REACTOR

    DOEpatents

    Treshow, M.

    1962-05-22

    A line connecting the reactor with a spent steam condenser contains a valve set to open when the pressure in the reactor exceeds a predetermined value and an orifice on the upstream side of the valve. Another line connects the reflector with this line between the orifice and the valve. An excess steam pressure causes the valve to open and the flow of steam through the line draws water out of the reflector. Provision is also made for adding water to the reflector when the steam pressure drops. (AEC)

  15. Water production in comet 81P/Wild 2 as determined by Herschel/HIFI

    NASA Astrophysics Data System (ADS)

    de Val-Borro, M.; Hartogh, P.; Crovisier, J.; Bockelée-Morvan, D.; Biver, N.; Lis, D. C.; Moreno, R.; Jarchow, C.; Rengel, M.; Szutowicz, S.; Banaszkiewicz, M.; Bensch, F.; Błęcka, M. I.; Emprechtinger, M.; Encrenaz, T.; Jehin, E.; Küppers, M.; Lara, L.-M.; Lellouch, E.; Swinyard, B. M.; Vandenbussche, B.; Bergin, E. A.; Blake, G. A.; Blommaert, J. A. D. L.; Cernicharo, J.; Decin, L.; Encrenaz, P.; de Graauw, T.; Hutsemékers, D.; Kidger, M.; Manfroid, J.; Medvedev, A. S.; Naylor, D. A.; Schieder, R.; Stam, D.; Thomas, N.; Waelkens, C.; Szczerba, R.; Saraceno, P.; di Giorgio, A. M.; Philipp, S.; Klein, T.; Ossenkopf, V.; Zaal, P.; Shipman, R.

    2010-10-01

    The high spectral resolution and sensitivity of Herschel/HIFI allows for the detection of multiple rotational water lines and accurate determinations of water production rates in comets. In this Letter we present HIFI observations of the fundamental 110-101 (557 GHz) ortho and 111-00 (1113 GHz) para rotational transitions of water in comet 81P/Wild 2 acquired in February 2010. We mapped the extent of the water line emission with five point scans. Line profiles are computed using excitation models which include excitation by collisions with electrons and neutrals and solar infrared radiation. We derive a mean water production rate of 1.0 × 1028 molecules s-1 at a heliocentric distance of 1.61 AU about 20 days before perihelion, in agreement with production rates measured from the ground using observations of the 18-cm OH lines. Furthermore, we constrain the electron density profile and gas kinetic temperature, and estimate the coma expansion velocity by fitting the water line shapes. Herschel is an ESA space observatory with science instruments provided by European-led Principal Investigator consortia and with important participation from NASA.Figure 5 (page 5) is only available in electronic form at http://www.aanda.org

  16. Thermal conductivity of supercooled water.

    PubMed

    Biddle, John W; Holten, Vincent; Sengers, Jan V; Anisimov, Mikhail A

    2013-04-01

    The heat capacity of supercooled water, measured down to -37°C, shows an anomalous increase as temperature decreases. The thermal diffusivity, i.e., the ratio of the thermal conductivity and the heat capacity per unit volume, shows a decrease. These anomalies may be associated with a hypothesized liquid-liquid critical point in supercooled water below the line of homogeneous nucleation. However, while the thermal conductivity is known to diverge at the vapor-liquid critical point due to critical density fluctuations, the thermal conductivity of supercooled water, calculated as the product of thermal diffusivity and heat capacity, does not show any sign of such an anomaly. We have used mode-coupling theory to investigate the possible effect of critical fluctuations on the thermal conductivity of supercooled water and found that indeed any critical thermal-conductivity enhancement would be too small to be measurable at experimentally accessible temperatures. Moreover, the behavior of thermal conductivity can be explained by the observed anomalies of the thermodynamic properties. In particular, we show that thermal conductivity should go through a minimum when temperature is decreased, as Kumar and Stanley observed in the TIP5P model of water. We discuss physical reasons for the striking difference between the behavior of thermal conductivity in water near the vapor-liquid and liquid-liquid critical points.

  17. Contrasting Secondary Organic Aerosol Formation in Aerosol Liquid Water During Summer and Winter

    NASA Astrophysics Data System (ADS)

    El-Sayed, M.; Hennigan, C. J.

    2017-12-01

    In this study, we characterize the formation of aqueous secondary organic aerosols (aqSOA) in the eastern United States during summer and winter. The aim was to identify the main factors affecting the reversible and irreversible uptake of water-soluble organic gases to aerosol liquid water under variable influence from biogenic and anthropogenic sources. The reversible and irreversible uptake of water-soluble organic gases to aerosol water was measured in Baltimore, MD using a recently developed on-line method. The formation of aqSOA was observed during the summer and the winter; however, the amount of aqSOA varied significantly between the two seasons, as did the reversible and irreversible nature of the uptake. While the availability of aerosol liquid water (ALW) predominantly controlled aqSOA formation in the summer, wintertime aqSOA formation was limited by precursor VOCs as well. During the summer, aqSOA formation was tightly linked with isoprene oxidation, while the aqSOA formed in the winter was associated with biomass burning. Irreversible aqSOA was formed in both seasons; however, reversible aqSOA was only observed in the summer. Overall, these results demonstrate the importance of multi-phase chemistry in aerosol formation and underscore the significance of soluble organic gases partitioning to aerosol water both reversibly and irreversibly.

  18. Genetic loci simultaneously controlling lignin monomers and biomass digestibility of rice straw.

    PubMed

    Hu, Zhen; Zhang, Guifen; Muhammad, Ali; Samad, Rana Abdul; Wang, Youmei; Walton, Jonathan D; He, Yuqing; Peng, Liangcai; Wang, Lingqiang

    2018-02-26

    Lignin content and composition are crucial factors affecting biomass digestibility. Exploring the genetic loci simultaneously affecting lignin-relevant traits and biomass digestibility is a precondition for lignin genetic manipulation towards energy crop breeding. In this study, a high-throughput platform was employed to assay the lignin content, lignin composition and biomass enzymatic digestibility of a rice recombinant inbred line population. Correlation analysis indicated that the absolute content of lignin monomers rather than lignin content had negative effects on biomass saccharification, whereas the relative content of p-hydroxyphenyl unit and the molar ratio of p-hydroxyphenyl unit to guaiacyl unit exhibited positive roles. Eight QTL clusters were identified and four of them affecting both lignin composition and biomass digestibility. The additive effects of clustered QTL revealed consistent relationships between lignin-relevant traits and biomass digestibility. Pyramiding rice lines containing the above four positive alleles for increasing biomass digestibility were selected and showed comparable lignin content, decreased syringyl or guaiacyl unit and increased molar percentage of p-hydroxyphenyl unit, the molar ratio of p-hydroxyphenyl unit to guaiacyl unit and sugar releases. More importantly, the lodging resistance and eating/cooking quality of pyramiding lines were not sacrificed, indicating the QTL information could be applied to select desirable energy rice lines.

  19. Arabian Sea as seen from STS-62

    NASA Image and Video Library

    1994-03-05

    STS062-86-196 (4-18 March 1994) --- This photo depicts many of the types of ocean features seen when illuminated by sunglint. These features include a shear line, bilge dump, currents and ship wakes. Winds, currents and oils effect the smoothness of the surface of the water. The oils smooth the water which reflect the sun more than the rougher surround water. This is seen in the bright curved line which is a bilge dump of oily water from a ship. The oils then start to take the form of the currents and in this case are also being blown by the surface winds. The shear line is approximately 240 miles west of Bombay, India. This shear line appears to be a result of two water masses, moving at slightly different speeds, having converged. Ship wakes, such as those in the photo, which cross a shear line, often give us an indication of the relative strenght of a a shear.

  20. Analysis Sharpens Mars Hydrogen Map, Hinting Equatorial Water Ice

    NASA Image and Video Library

    2017-09-28

    Re-analysis of 2002-2009 data from a hydrogen-finding instrument on NASA's Mars Odyssey orbiter increased the resolution of maps of hydrogen abundance. The reprocessed data (lower map) shows more "water-equivalent hydrogen" (darker blue) in some parts of this equatorial region of Mars. Puzzingly, this suggests the possible presence of water ice just beneath the surface near the equator, though it would not be thermodynamically stable there. The upper map uses raw data from Odyssey's neutron spectrometer instrument, which senses the energy state of neutrons coming from Mars, providing an indication of how much hydrogen is present in the top 3 feet (1 meter) of the surface. Hydrogen detected by Odyssey at high latitudes of Mars in 2002 was confirmed to be in the form of water ice by the follow-up NASA Phoenix Mars Lander mission in 2008. A 2017 reprocessing of the older data applied image-reconstruction techniques often used to reduce blurring from medical imaging data. The results are shown here for an area straddling the equator for about one-fourth the circumference of the planet, centered at 175 degrees west longitude. The white contours outline lobes of a formation called Medusae Fossae, coinciding with some areas of higher hydrogen abundance in the enhanced-resolution analysis. The black line indicates the limit of a relatively young lava plain, coinciding with areas of lower hydrogen abundance in the enhanced-resolution analysis. The color-coding key for hydrogen abundance in both maps is indicated by the horizontal bar, in units expressed as how much water would be present in the ground if the hydrogen is all in the form of water. Units of the equivalent water weight, as a percentage of the material in the ground, are correlated with counts recorded by the spectrometer, ranging from less than 1 weight-percent water equivalent (red) to more than 30 percent (dark blue). https://photojournal.jpl.nasa.gov/catalog/PIA21848

  1. Reduction of DOM fractions and their trihalomethane formation potential in surface river water by in-line coagulation with ceramic membrane filtration.

    PubMed

    Rakruam, Pharkphum; Wattanachira, Suraphong

    2014-03-01

    This research was aimed at investigating the reduction of DOM fractions and their trihalomethane formation potential (THMFP) by in-line coagulation with 0.1 μm ceramic membrane filtration. The combination of ceramic membrane filtration with a coagulation process is an alternative technology which can be applied to enhance conventional coagulation processes in the field of water treatment and drinking water production. The Ping River water (high turbidity water) was selected as the raw surface water because it is currently the main raw water source for water supply production in the urban and rural areas of Chiang Mai Province. From the investigation, the results showed that the highest percent reductions of DOC, UV-254, and THMFP (47.6%, 71.0%, and 67.4%, respectively) were achieved from in-line coagulation with ceramic membrane filtration at polyaluminum chloride dosage 40 mg/L. Resin adsorption techniques were employed to characterize the DOM in raw surface water and filtered water. The results showed that the use of a ceramic membrane with in-line coagulation was able to most efficiently reduce the hydrophobic fraction (HPOA) (68.5%), which was then followed by the hydrophilic fraction (HPIA) (49.3%). The greater mass DOC reduction of these two fractions provided the highest THMFP reductions (55.1% and 37.2%, respectively). Furthermore, the in-line coagulation with ceramic membrane filtration was able to reduce the hydrophobic (HPOB) fraction which is characterized by high reactivity toward THM formation. The percent reduction of mass DOC and THMFP of HPOB by in-line coagulation with ceramic membrane filtration was 45.9% and 48.0%, respectively. Copyright © 2014 The Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences. Published by Elsevier B.V. All rights reserved.

  2. Microbial Community Profile of a Lead Service Line Removed from a Drinking Water Distribution System▿

    PubMed Central

    White, Colin; Tancos, Matthew; Lytle, Darren A.

    2011-01-01

    A corroded lead service line was removed from a drinking water distribution system, and the microbial community was profiled using 16S rRNA gene techniques. This is the first report of the characterization of a biofilm on the surface of a corroded lead drinking water service line. The majority of phylotypes have been linked to heavy-metal-contaminated environments. PMID:21652741

  3. Hydrogeologic framework of the North Carolina coastal plain

    USGS Publications Warehouse

    Winner, M.D.; Coble, R.W.

    1996-01-01

    The hydrogeologic framework of the North Carolina Coastal Plain aquifer system consists of 10 aquifers separated by 9 confining units. From top to bottom, the aquifers are the surficial aquifer, Yorktown aquifer, Pungo River aquifer, Castle Hayne aquifer, Beaufort aquifer, Peedee aquifer, Black Creek aquifer, upper Cape Fear aquifer, lower Cape Fear aquifer, and Lower Cretaceous aquifer. The uppermost aquifer (the surficial aquifer in most places) is a water-table aquifer, and the bottom of the system is underlain by crystalline bedrock. The sedimentary deposits forming the aquifers are of Holocene to Cretaceous age and are composed mostly of sand, with lesser amounts of gravel and limestone. The confining units between the aquifers are composed primarily of clay and silt. The thickness of the aquifers ranges from zero along the Fall Line to more than 10,000 feet at Cape Hatteras. Prominent structural features are the increasing easterly homoclinal dip of the sediments and the Cape Fear arch, the axis of which trends in a southeast direction. Stratigraphic continuity was determined from correlations of 161 geophysical logs along with data from drillers? and geologists? logs. Aquifers were defined by means of these logs as well as water-level and water-quality data and evidence of the continuity of pumping effects. Eighteen hydrogeologic sections depict the correlation of these aquifers throughout the North Carolina Coastal Plain.

  4. Seasonal and spatial patterns in diurnal cycles in streamflow in the western United States

    USGS Publications Warehouse

    Lundquist, J.D.; Cayan, D.R.

    2002-01-01

    The diurnal cycle in streamflow constitutes a significant part of the variability in many rivers in the western United States and can be used to understand some of the dominant processes affecting the water balance of a given river basin. Rivers in which water is added diurnally, as in snowmelt, and rivers in which water is removed diurnally, as in evapotranspiration and infiltration, exhibit substantial differences in the timing, relative magnitude, and shape of their diurnal flow variations. Snowmelt-dominated rivers achieve their highest sustained flow and largest diurnal fluctuations during the spring melt season. These fluctuations are characterized by sharp rises and gradual declines in discharge each day. In large snowmelt-dominated basins, at the end of the melt season, the hour of maximum discharge shifts to later in the day as the snow line retreats to higher elevations. Many evapotranspiration/infiltration-dominated rivers in the western states achieve their highest sustained flows during the winter rainy season but exhibit their strongest diurnal cycles during summer months, when discharge is low, and the diurnal fluctuations compose a large percentage of the total flow. In contrast to snowmelt-dominated rivers, the maximum discharge in evapotranspiration/infiltration-dominated rivers occurs consistently in the morning throughout the summer. In these rivers, diurnal changes are characterized by a gradual rise and sharp decline each day.

  5. STS-35 stowage volume G with contingency water container (CWC) onboard OV-102

    NASA Technical Reports Server (NTRS)

    1990-01-01

    During STS-35, middeck stowage volume G and a contingency water container (CWC) were utilized to remedy a problem onboard Columbia, Orbiter Vehicle (OV) 102. A hose connecting OV-102's waste water system to the CWC was used in order to bypass a suspected clog in the line from the waste water tank to the exit nozzle. On flight day seven, Pilot Guy S. Gardner carried out an inflight maintenance (IFM) procedure by connecting a spare hose from the line to the container. The CWC is a rubber-lined duffle bag that holds about 95 pounds of water and is used in situations where water cannot be dumped overboard normally.

  6. Waterborne Transportation Lines of the United States : calendar year 2004. Volume 1 : national summaries

    DOT National Transportation Integrated Search

    2005-12-15

    The annual revision of the Waterborne : Transportation Lines of the United States : (WTLUS) contains summary information of : the vessel companies and their American : flag vessels operating or available for : operation on 31 December 2004 including ...

  7. Integration of the Anammox process to the rejection water and main stream lines of WWTPs.

    PubMed

    Morales, Nicolás; Val Del Río, Ángeles; Vázquez-Padín, José Ramón; Méndez, Ramón; Mosquera-Corral, Anuska; Campos, José Luis

    2015-12-01

    Nowadays the application of Anammox based processes in the wastewater treatment plants has given a step forward. The new goal consists of removing the nitrogen present in the main stream of the WWTPs to improve their energetic efficiencies. This new approach aims to remove not only the nitrogen but also to provide a better use of the energy contained in the organic matter. The organic matter will be removed either by an anaerobic psychrophilic membrane reactor or an aerobic stage operated at low solids retention time followed by an anaerobic digestion of the generated sludge. Then ammonia coming from these units will be removed in an Anammox based process in a single unit system. The second strategy provides the best results in terms of operational costs and would allow reductions of about 28%. Recent research works performed on Anammox based processes and operated at relatively low temperatures and/or low ammonia concentrations were carried out in single-stage systems using biofilms, granules or a mixture of flocculent nitrifying and granular Anammox biomasses. These systems allowed the appropriated retention of Anammox and ammonia oxidizing bacteria but also the proliferation of nitrite oxidizing bacteria which seems to be the main drawback to achieve the required effluent quality for disposal. Therefore, prior to the implementation of the Anammox based processes at full scale to the water line, a reliable strategy to avoid nitrite oxidation should be defined in order to maintain the process stability and to obtain the desired effluent quality. If not, the application of a post-denitrification step should be necessary. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. 7 CFR 60.132 - Waters of the United States.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 3 2012-01-01 2012-01-01 false Waters of the United States. 60.132 Section 60.132... FOR FISH AND SHELLFISH General Provisions Definitions § 60.132 Waters of the United States. Waters of the United States means those fresh and ocean waters contained within the outer limit of the Exclusive...

  9. 7 CFR 60.132 - Waters of the United States.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Waters of the United States. 60.132 Section 60.132... FOR FISH AND SHELLFISH General Provisions Definitions § 60.132 Waters of the United States. Waters of the United States means those fresh and ocean waters contained within the outer limit of the Exclusive...

  10. [Microbial settlement of paint- and building-materials in the sphere of drinking water. 5. Communication: Macrocolonies on the cement mortar lining in a water main (author's transl)].

    PubMed

    Schoenen, D

    1980-09-01

    It is reported a microbial growth in form of macrocolonies on a cement mortar line in a potable water main. Simultaneously an increase of bacterial content in the water could be observed. The bacterial content could be reduced by chlorination, but the microbial growth on the surface of the lining was not suppressed. Macrocolonies could be observed the same as before at the last inspection 6 1/2 years after opening of the main.

  11. Water flowing north of the border: export agriculture and water politics in a rural community in Baja California.

    PubMed

    Zlolniski, Christian

    2011-01-01

    Favored by neoliberal agrarian policies, the production of fresh crops for international markets has become a common strategy for economic development in Mexico and other Latin American countries. But as some scholars have argued, the global fresh produce industry in developing countries in which fresh crops are produced for consumer markets in affluent nations implies “virtual water flows,” the transfer of high volumes of water embedded in these crops across international borders. This article examines the local effects of the production of fresh produce in the San Quintín Valley in northwestern Mexico for markets in the United States. Although export agriculture has fostered economic growth and employment opportunities for indigenous farm laborers, it has also led to the overexploitation of underground finite water resources, and an alarming decline of the quantity and quality of water available for residents’ domestic use. I discuss how neoliberal water policies have further contributed to water inequalities along class and ethnic lines, the hardships settlers endure to secure access to water for their basic needs, and the political protests and social tensions water scarcity has triggered in the region. Although the production of fresh crops for international markets is promoted by organizations such as the World Bank and Inter-American Development Bank as a model for economic development, I argue that it often produces water insecurity for the poorest, threatening the UN goal of ensuring access to clean water as a universal human right.

  12. Advanced Diesel Oil Fuel Processor Development

    DTIC Science & Technology

    1986-06-01

    water exit 29 sample quencher: gas sample line inlet 30 sample quencher: gas sample line exit 31 sample quencher: cooling water inlet 32 desulfuriser ...exit line 33, 34 desulfurimer 35 heat exchanger: process gas exit (to desulfuriser ) 38 shift reactor inlet (top) 37 shift reactor: cooling air exit

  13. Hydrogeology of the interstream area between Ty Ty Creek and Ty Ty Creek tributary near Plains, Georgia

    USGS Publications Warehouse

    Stewart, Lisa M.; Hicks, David W.

    1996-01-01

    This report is part of an interdisciplinary effort to identify and describe processes that control movement and fate of selected fertilizers and pesticides in the surface and subsurface environments in the Fall Line Hills district of the Georgia Coastal Plain physiographic province. This report describes the hydrogeology of the interstream area between Ty Ty Creek and it's tributary near Plains, Sumter County, Georgia. Geologic units of interest to this study are, in ascending order, (1) the Tuscahoma Formation, a bluish gray, silty clay; (2) the Tallahatta Formation, a fine-to-coarse, poorly sorted quartz sand that is divided into an upper and lower unit; and (3) the undifferentiated overburden, which consists of fine to medium poorly sorted sand, silt and clay. Continuous-core samples indicate that the unsaturated zone includes the undifferentiated overburden and the upper unit of the Tallahatta Formation, and attains a maximum thickness of about 52 feet (ft) in the southern part of the study area. The Claiborne aquifer in the study area consists of the lower unit of the Tallahatta Formation and ranges in thickness from 3 ft near Ty Ty Creek tributary to about 20 ft in the upland divide area. It is confined below by the clayey sediments of the Tuscahoma Formation. The Claiborne aquifer in the study area generally is confined above by an extensive clay layer that is the base if the upper unit of the Tallahatta Formation. Fluctuations in the amount of vertical recharge to the aquifer result in areal and temporal changes in aquifer conditions from confined to unconfined in parts of the study area. Hydraulic conductivity of the aquifer ranges from 3.5 to 7 feet per day. The transmissivity of the aquifer is approximately 50 feet squared per day. Water-level data indicate the potentiometric surface slopes to the south, southeast, and southwest with a gradient of about 87 to 167 feet per mile. The shape of the potentiometric surface and the direction of groundwater flow remains relatively unchanged during high and low water-level periods. Water levels in the Claiborne aquifer fluctuated by a maximum of 6 ft during the period from January to December 1991. Recharge to the Claiborne aquifer consists of a local and regional flow component. Lateral ground-water flow (regional flow) into the study area is dependent on regional hydraulic controls (pumpage, stream discharge, and rainfall). The rate of lateral movement of ground water is dependent on the hydraulic conductivity of the saturated zone, the hydraulic gradient, and other hydraulic factors, and is considered to be relatively constant. Local recharge enters the ground-water system as rainfall that percolates down to the water table. Annual water-level fluctuations in the Claiborne aquifer indicate that the majority of regional and local recharge occurs in the interstream area with recharge decreasing downslope to the streams. Ground water discharges to Ty Ty Creek and it's tributary throughout the year during low and high water-level periods.

  14. National water quality assessment of the Georgia-Florida Coastal Plain study unit; water withdrawals and treated wastewater discharges, 1990

    USGS Publications Warehouse

    Marella, R.L.; Fanning, J.L.

    1996-01-01

    The Georgia-Florida Coastal Plain study unit covers nearly 62,600 square miles along the southeastern United States coast in Georgia and Florida. In 1990, the estimated population of the study unit was 9.3 million, and included all or part of the cities of Atlanta, Jacksonville, Orlando, Tampa, and St. Petersburg. Estimated freshwater withdrawn in the study unit in 1990 was nearly 5,075 million gallons per day. Ground-water accounted for more than 57 percent of the water withdrawn during 1990 and the Floridan aquifer system provided nearly 91 percent of the total ground-water withdrawn. Surface-water accounted for nearly 43 percent of the water withdrawn in the study unit in 1990 with large amounts of withdrawals from the Altamaha River, Hillsborough River, the Ocmulgee River, the Oconee River, the St. Johns River, and the Suwannee River. Water withdrawn for public supply in the Georgia-Florida Coastal Plain study unit in 1990 totaled 1,139 million gallons per day, of which 83 percent was ground water and 17 percent was surface water. Self-supplied domestic withdrawals in the Georgia-Florida Coastal Plain study unit in 1990 totaled nearly 230 million gallons per day. Ground water supplied over 80 percent of the study units population for drining water purposes; nearly 5.8 million people were served by public supply and 1.8 million people were served by self-supplied systems. Water withdrawn for self-supplied domestic use in Georgia and Florida is derived almost exclusively from ground water, primarily because this source can provide the quantity and quality of water needed for drinking purposes. Nearly 1.7 million people served by public supply utilized surface water for their drinking water needs. Water withdrawn for self-supplied commercial-industrial uses in the study unit in 1990 totaled 862 million gallons per day, of which 93 percent was ground water and 7 percent was surface water. Water withdrawn for agriculture purposes in the study unit in 1990 totaled 1,293 million gallons per day, of which 69 percent was ground water and 31 percent was surface water. An estimated 1.254 millon acres were irrigated within the study unit during 1990. Water withdrawn for thermoelectric power generation in the study unit in 1990 totaled 1,552 million gallons per day, of which 99 percent was surface water and 1 percent was ground water. An additional 6,919 million gallons per day of saline surface water were withdrawn for thermoelectric power generation in 1990, solely for cooling purposes. Treated wastewater discharged within the Georgia-Florida Coastal Plain study unit totaled nearly 1,187 million gallons per day in 1990. Of the total water discharged, 58 percent was discharged directly into surface water and the remaining 42 percent was discharged to ground water (through drain fields, injection wells, percolation ponds or spray fields). Domestic wastewater facilities discharged in the study unit totaled nearly 789 million gallons per day, industrial wastewater facilities discharged 213 million gallons per day, and releases from septic tanks was estimated at 185 million gallons per day. More than 1.3 million septic tanks were estimated in use within the study unit in 1990.

  15. Waste to Watts and Water: Enabling Self-Contained Facilities Using Microbial Fuel Cells

    DTIC Science & Technology

    2008-05-01

    suitable growing medium. LOC - Line of communications . Used in a military sense to indicate a main supply route. It includes transportation by ships...fresh water. Self-Contained Facilities - Facilities that do not rely on outside infrastructure or lines of communication for utilities such as water...require in future facilities is the ability to operate cleanly and efficiently apart from the infrastructure network and line of communications (LOCs) both

  16. Fault finder

    DOEpatents

    Bunch, Richard H.

    1986-01-01

    A fault finder for locating faults along a high voltage electrical transmission line. Real time monitoring of background noise and improved filtering of input signals is used to identify the occurrence of a fault. A fault is detected at both a master and remote unit spaced along the line. A master clock synchronizes operation of a similar clock at the remote unit. Both units include modulator and demodulator circuits for transmission of clock signals and data. All data is received at the master unit for processing to determine an accurate fault distance calculation.

  17. Interface For Fault-Tolerant Control System

    NASA Technical Reports Server (NTRS)

    Shaver, Charles; Williamson, Michael

    1989-01-01

    Interface unit and controller emulator developed for research on electronic helicopter-flight-control systems equipped with artificial intelligence. Interface unit interrupt-driven system designed to link microprocessor-based, quadruply-redundant, asynchronous, ultra-reliable, fault-tolerant control system (controller) with electronic servocontrol unit that controls set of hydraulic actuators. Receives digital feedforward messages from, and transmits digital feedback messages to, controller through differential signal lines or fiber-optic cables (thus far only differential signal lines have been used). Analog signals transmitted to and from servocontrol unit via coaxial cables.

  18. 40 CFR 63.1566 - What are my requirements for organic HAP emissions from catalytic reforming units?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Petroleum Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Catalytic Cracking Units, Catalytic Reforming Units, Sulfur Recovery Units, and Bypass Lines § 63.1566 What...

  19. INTERNATIONAL SOURCE WATER TOXICITY MONITORING CONSORTIUM

    EPA Science Inventory

    Many researchers in the field of time-relevant, on-line toxicity monitors for source water protection believe that some mechanism to guide and prioritize research in this emerging field would be beneficial. On-line toxicity monitors are tools designed to screen water quality and ...

  20. Using Triple Oxygen Isotope Analyses of Biogenic Carbonate to Reconstruct Early Triassic Ocean Oxygen Isotopic Values and Temperatures

    NASA Astrophysics Data System (ADS)

    Gibbons, J. A.; Sharp, Z. D.; Atudorei, V.

    2017-12-01

    The calcite-water triple oxygen isotope fractionation is used to determine isotopic equilibrium and ancient ocean oxygen isotopic values and temperatures. Unlike conventional δ18O analysis where the formation water's isotopic value is assumed, paired δ17O-δ18O measurements allow for the water's isotopic composition to be calculated because there is only one unique solution for equilibrium fractionation using Δ17O-δ18O values (where Δ17O=δ17O-0.528δ18O). To a first approximation, the calcite-water equilibrium fractionation factor, θ (where θ=ln17α/ln18α), varies with temperature by 0.00001/°. The calcite-water equilibrium fractionation line was determined at two temperatures, 30° and 0°, by using modern carbonate samples that formed in ocean water with a δ18O value of 0‰. The θ values for the 30° and 0° samples are 0.52515 and 0.52486, respectively. Oxygen values were measured using complete fluorination in nickel tubes with BrF5 as the reaction reagent. We calibrated all oxygen values to the SMOW-SLAP scale by measuring SMOW, SLAP, San Carlos olivine, NBS-18, NBS-19, and PDB. The triple oxygen isotope calcite-water equilibrium fractionation line was applied to well preserved Early Triassic ammonite shells from the Western United States. Based on paired δ17O-δ18O measurements, the samples did not form in equilibrium with an ice-free ocean with an oxygen isotopic value of -1‰ or the modern ocean value of 0‰. Assuming the calcite is still primary and formed in equilibrium with the ocean water, our data indicate that the δ18O value of the ocean in the early Triassic was 3-5‰ lower than modern. Samples from the Smithian thermal maximum formed in water 10° warmer than samples from after the thermal maximum. Paired δ17O-δ18O measurements of pristine ancient carbonates may provide a better understanding of past ocean conditions during climate change events.

  1. Active microwave negative-index metamaterial transmission line with gain.

    PubMed

    Jiang, Tao; Chang, Kihun; Si, Li-Ming; Ran, Lixin; Xin, Hao

    2011-11-11

    We studied the active metamaterial transmission line at microwave frequency. The active composite right-handed or left-handed transmission line was designed to incorporate a germanium tunnel diode with a negative differential resistance property as the gain device at the unit cell level. Measurements of the fabricated planar transmission line structures with one-, two-, and three-unit cells showed that the addition of the dc pumped tunnel diodes not only provided gain but also maintained the left handedness of the transmission line metamaterial. Simulation results agree well with experimental observation. This work demonstrated that negative index material can be obtained with a net gain when an external source is incorporated.

  2. Development of a Handheld Line Information Reader and Generator for Efficient Management of Optical Communication Lines

    PubMed Central

    Lee, Jaeyul; Kwon, Hyungwoo; Song, Jaewon; Jeon, Mansik; Kim, Jeehyun

    2017-01-01

    A handheld line information reader and a line information generator were developed for the efficient management of optical communication lines. The line information reader consists of a photo diode, trans-impedance amplifier, voltage amplifier, microcontroller unit, display panel, and communication modules. The line information generator consists of a laser diode, laser driving circuits, microcontroller unit, and communication modules. The line information reader can detect the optical radiation field of the test line by bending the optical fiber. To enhance the sensitivity of the line information reader, an additional lens was used with a focal length of 4.51 mm. Moreover, the simulation results obtained through BeamPROP® software from Synopsys, Inc. demonstrated a stronger optical radiation field of the fiber due to a longer transmission wavelength and larger bending angle of the fiber. Therefore, the developed devices can be considered as useful tools for the efficient management of optical communication lines. PMID:28837058

  3. Microbiological corrosion of ASTM SA105 carbon steel pipe for industrial fire water usage

    NASA Astrophysics Data System (ADS)

    Chidambaram, S.; Ashok, K.; Karthik, V.; Venkatakrishnan, P. G.

    2018-02-01

    The large number of metallic systems developed for last few decades against both general uniform corrosion and localized corrosion. Among all microbiological induced corrosion (MIC) is attractive, multidisciplinary and complex in nature. Many chemical processing industries utilizes fresh water for fire service to nullify major/minor fire. One such fire water service line pipe attacked by micro-organisms leads to leakage which is industrially important from safety point of view. Also large numbers of leakage reported in similar fire water service of nearby food processing plant, paper & pulp plant, steel plant, electricity board etc…In present investigation one such industrial fire water service line failure analysis of carbon steel line pipe was analyzed to determine the cause of failure. The water sample subjected to various chemical and bacterial analyses. Turbidity, pH, calcium hardness, free chlorine, oxidation reduction potential, fungi, yeasts, sulphide reducing bacteria (SRB) and total bacteria (TB) were measured on water sample analysis. The corrosion rate was measured on steel samples and corrosion coupon measurements were installed in fire water for validating non flow assisted localized corrosion. The sulphide reducing bacteria (SRB) presents in fire water causes a localized micro biological corrosion attack of line pipe.

  4. A modular finite-element model (MODFE) for areal and axisymmetric ground-water-flow problems, Part 2: Derivation of finite-element equations and comparisons with analytical solutions

    USGS Publications Warehouse

    Cooley, Richard L.

    1992-01-01

    MODFE, a modular finite-element model for simulating steady- or unsteady-state, area1 or axisymmetric flow of ground water in a heterogeneous anisotropic aquifer is documented in a three-part series of reports. In this report, part 2, the finite-element equations are derived by minimizing a functional of the difference between the true and approximate hydraulic head, which produces equations that are equivalent to those obtained by either classical variational or Galerkin techniques. Spatial finite elements are triangular with linear basis functions, and temporal finite elements are one dimensional with linear basis functions. Physical processes that can be represented by the model include (1) confined flow, unconfined flow (using the Dupuit approximation), or a combination of both; (2) leakage through either rigid or elastic confining units; (3) specified recharge or discharge at points, along lines, or areally; (4) flow across specified-flow, specified-head, or head-dependent boundaries; (5) decrease of aquifer thickness to zero under extreme water-table decline and increase of aquifer thickness from zero as the water table rises; and (6) head-dependent fluxes from springs, drainage wells, leakage across riverbeds or confining units combined with aquifer dewatering, and evapotranspiration. The matrix equations produced by the finite-element method are solved by the direct symmetric-Doolittle method or the iterative modified incomplete-Cholesky conjugate-gradient method. The direct method can be efficient for small- to medium-sized problems (less than about 500 nodes), and the iterative method is generally more efficient for larger-sized problems. Comparison of finite-element solutions with analytical solutions for five example problems demonstrates that the finite-element model can yield accurate solutions to ground-water flow problems.

  5. Subsurface phosphorus transport through a no-till field in the semi arid Palouse region

    NASA Astrophysics Data System (ADS)

    Norby, J. C.; Brooks, E. S.; Strawn, D. G.

    2017-12-01

    Excess application of fertilizers containing nitrogen and phosphorus for farming use has led to ongoing water quality issues in the United States. When these nutrients leave agronomic systems, and enter water bodies in large quantities, algal bloom and eutrophication can occur. Extensive studies focusing on phosphorus as a pollutant from agronomic systems have been conducted in the many regions of the United States; however, there has been a lack of studies completed in the semiarid Palouse region of eastern Washington and western Idaho. The goal of this research study was to better understand how no-till farm management has altered soil P temporally and the current availability for off-site transport of P throughout an artificially drained catchment at the Cook Agronomy Farm in Pullman, WA. We also attempted to determine the processes responsible for subsurface flow of phosphorus, specifically through preferential flow pathways. Dissolved reactive P (DRP)concentrations of subsurface drainage from a artificial drain exceeded TMDL threshold concentrations during numerous seasonal high flow events over the two-year study time frame. Soil analyses show a highly variable distribution of water-extractable P across the sub-catchment area and initial results suggest a translocation of P species deeper into the soil profile after implementing no-till practices in 1998. We hypothesized that a greater network of macropores from lack of soil disturbance allow for preferential flow of nutrient-laden water deeper into the subsurface and to the artificial drain system. Simulated flow experiments on soil cores from the study site showed large-scale macropore development, extreme variability in soil conductivity, and high P adsorption potential for the soils, suggesting a disconnect between P movement through macropore soil and subsurface drainage water rich in DRP at the artificial drain line outlet.

  6. Splitting Terraced Houses Into Single Units Using Oblique Aerial Imagery

    NASA Astrophysics Data System (ADS)

    Dahlke, D.

    2017-05-01

    This paper introduces a method to subdivide complex building structures like terraced houses into single house units comparable to units available in a cadastral map. 3D line segments are detected with sub-pixel accuracy in traditional vertical true orthomosaics as well as in innovative oblique true orthomosaics and their respective surface models. Hereby high gradient strengths on roofs as well as façades are taken into account. By investigating the coplanarity and frequencies within a set of 3D line segments, individual cut lines for a building complex are found. The resulting regions ideally describe single houses and thus the object complexity is reduced for subsequent topological, semantical or geometrical considerations. For the chosen study area with 70 buidling outlines a hit rate of 80% for cut lines is achieved.

  7. Terminal drought-tolerant pearl millet [Pennisetum glaucum (L.) R. Br.] have high leaf ABA and limit transpiration at high vapour pressure deficit

    PubMed Central

    Kholová, Jana; Hash, C. T.; Kumar, P. Lava; Yadav, Rattan S.; Kočová, Marie; Vadez, Vincent

    2010-01-01

    It was previously shown that pearl millet genotypes carrying a terminal drought tolerance quantitative trait locus (QTL) had a lower transpiration rate (Tr; g cm−2 d−1) under well-watered conditions than sensitive lines. Here experiments were carried out to test whether this relates to leaf abscisic acid (ABA) and Tr concentration at high vapour pressure deficit (VPD), and whether that leads to transpiration efficiency (TE) differences. These traits were measured in tolerant/sensitive pearl millet genotypes, including near-isogenic lines introgressed with a terminal drought tolerance QTL (NIL-QTLs). Most genotypic differences were found under well-watered conditions. ABA levels under well-watered conditions were higher in tolerant genotypes, including NIL-QTLs, than in sensitive genotypes, and ABA did not increase under water stress. Well-watered Tr was lower in tolerant than in sensitive genotypes at all VPD levels. Except for one line, Tr slowed down in tolerant lines above a breakpoint at 1.40–1.90 kPa, with the slope decreasing >50%, whereas sensitive lines showed no change in that Tr response across the whole VPD range. It is concluded that two water-saving (avoidance) mechanisms may operate under well-watered conditions in tolerant pearl millet: (i) a low Tr even at low VPD conditions, which may relate to leaf ABA; and (ii) a sensitivity to higher VPD that further restricts Tr, which suggests the involvement of hydraulic signals. Both traits, which did not lead to TE differences, could contribute to absolute water saving seen in part due to dry weight increase differences. This water saved would become critical for grain filling and deserves consideration in the breeding of terminal drought-tolerant lines. PMID:20142425

  8. Terminal drought-tolerant pearl millet [Pennisetum glaucum (L.) R. Br.] have high leaf ABA and limit transpiration at high vapour pressure deficit.

    PubMed

    Kholová, Jana; Hash, C T; Kumar, P Lava; Yadav, Rattan S; Kocová, Marie; Vadez, Vincent

    2010-03-01

    It was previously shown that pearl millet genotypes carrying a terminal drought tolerance quantitative trait locus (QTL) had a lower transpiration rate (Tr; g cm(-2) d(-1)) under well-watered conditions than sensitive lines. Here experiments were carried out to test whether this relates to leaf abscisic acid (ABA) and Tr concentration at high vapour pressure deficit (VPD), and whether that leads to transpiration efficiency (TE) differences. These traits were measured in tolerant/sensitive pearl millet genotypes, including near-isogenic lines introgressed with a terminal drought tolerance QTL (NIL-QTLs). Most genotypic differences were found under well-watered conditions. ABA levels under well-watered conditions were higher in tolerant genotypes, including NIL-QTLs, than in sensitive genotypes, and ABA did not increase under water stress. Well-watered Tr was lower in tolerant than in sensitive genotypes at all VPD levels. Except for one line, Tr slowed down in tolerant lines above a breakpoint at 1.40-1.90 kPa, with the slope decreasing >50%, whereas sensitive lines showed no change in that Tr response across the whole VPD range. It is concluded that two water-saving (avoidance) mechanisms may operate under well-watered conditions in tolerant pearl millet: (i) a low Tr even at low VPD conditions, which may relate to leaf ABA; and (ii) a sensitivity to higher VPD that further restricts Tr, which suggests the involvement of hydraulic signals. Both traits, which did not lead to TE differences, could contribute to absolute water saving seen in part due to dry weight increase differences. This water saved would become critical for grain filling and deserves consideration in the breeding of terminal drought-tolerant lines.

  9. The Evolution of Volatile Production in Comet C-2009 P1(Garradd) During its 2011-2012 Apparition

    NASA Technical Reports Server (NTRS)

    Gicquel, A.; Milam, S. N.; Coulson, I. M.; Villaneuva, G. L.; Cordiner, M. A.; Charnley, S. B.; DiSanti, M. A.; Mumma, M. J.; Szutowicz, S.

    2015-01-01

    We report observations at millimeter and submillimeter wavelengths of comet C/2009 P1 (Garradd) from 2011 December 28 to 2012 April 24, using the Arizona Radio Observatory submillimeter telescope (SMT) and the James Clerk Maxwell Telescope (JCMT). Garradd is a dynamically young long-period comet from the Oort Cloud, with a periodicity of 127,000 years, that reached perihelion on 2011 December 23 (at Heliocentric distance (Rh) = 1.55 Astronomical Units and delta = 20.1 Astronomical Units ) and made its closest approach to the Earth on 2012 March 05 (at Heliocentric distance (Rh) = 1.84 Astronomical Units and delta = 1.26 Astronomical Units). We obtained gas production rates, and molecular abundances relative to water for HCN, ortho-H2CO, CS, CO and CH3OH. A rotational temperature, T (sub rot) approximately equal to 50 degrees Kelvin, was determined by observing multiple methanol lines with the JCMT. By averaging the abundance ratio relative to water from the SMT and the JCMT we derive: CO: 7.03 plus or minus 1.84 percent, HCN: 0.04 plus or minus 0.01 percent, ortho H2CO: 0.14 plus or minus 0.03 percent as a parent molecule (and 0.28 plus or minus 0.06 percent as an extended source), CS: 0.03 plus or minus 0.01 percent and CH3OH: 3.11 for a range from plus 1:86 to minus 0.51 percent. We concluded that Garradd is normal in CH3OH, depleted in HCN, ortho-H2CO and CS and slightly enriched in CO with respect to typically observed cometary mixing ratios. We also studied the temporal evolution of HCN and CO and find that the production of HCN has a trend similar to water (but with short-term variation), with a decrease after perihelion, while that of CO shows contrary behavior: remaining constant or increasing after perihelion.

  10. 18 CFR 2.2 - Transmission lines.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 18 Conservation of Power and Water Resources 1 2011-04-01 2011-04-01 false Transmission lines. 2.2 Section 2.2 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF... Under the Federal Power Act § 2.2 Transmission lines. In a public statement dated March 7, 1941, the...

  11. The molecular structure of the phosphate mineral chalcosiderite - A vibrational spectroscopic study

    NASA Astrophysics Data System (ADS)

    Frost, Ray L.; Xi, Yunfei; Scholz, Ricardo; Ribeiro, Carlos Augusto de Brito

    2013-07-01

    The mineral chalcosiderite with formula CuFe6(PO4)4(OH)8ṡ4H2O has been studied by Raman spectroscopy and by infrared spectroscopy. A comparison of the chalcosiderite spectra is made with the spectra of turquoise. The spectra of the mineral samples are very similar in the 1200-900 cm-1 region but strong differences are observed in the 900-100 cm-1 region. The effect of substitution of Fe for Al in chalcosiderite shifts the bands to lower wavenumbers. Factor group analysis (FGA) implies four OH stretching vibrations for both the water and hydroxyl units. Two bands ascribed to water are observed at 3276 and 3072 cm-1. Three hydroxyl stretching vibrations are observed. Calculations using a Libowitzky type formula show that the hydrogen bond distances of the water molecules are 2.745 and 2.812 Å which are considerably shorter than the values for the hydroxyl units 2.896, 2.917 and 2.978 Å. Two phosphate stretching vibrations at 1042 and 1062 cm-1 in line with the two independent phosphate units in the structure of chalcosiderite. Three bands are observed at 1102, 1159 and 1194 cm-1 assigned to the phosphate antisymmetric stretching vibrations. FGA predicts six bands but only three are observed due to accidental degeneracy. Both the ν2 and ν4 bending regions are complex. Four Raman bands observed at 536, 580, 598 and 636 cm-1 are assigned to the ν4 bending modes. Raman bands at 415, 420, 475 and 484 cm-1are assigned to the phosphate ν2 bending modes. Vibrational spectroscopy enables aspects of the molecular structure of chalcosiderite to be assessed.

  12. STS-35 stowage volume G with contingency water container (CWC) onboard OV-102

    NASA Image and Video Library

    1990-12-08

    STS035-12-005 (2-10 Dec 1990) --- During STS-35, middeck stowage volume G and a contingency water container (CWC) were utilized to remedy a problem onboard Columbia, Orbiter Vehicle (OV) 102. A hose connecting OV-102's waste water system to the CWC was used in order to bypass a suspected clog in the line from the waste water tank to the exit nozzle. On flight day seven, Pilot Guy S. Gardner carried out an inflight maintenance (IFM) procedure by connecting a spare hose from the line to the container. The CWC is a rubber-lined duffle bag that holds about 95 pounds of water and is used in situations where water cannot be dumped overboard normally.

  13. Removal of gasoline volatile organic compounds via air biofiltration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, R.S.; Saberiyan, A.G.; Esler, C.T.

    1995-12-31

    Volatile organic compounds (VOCs) generated by vapor extraction and air-stripping systems can be biologically treated in an air biofiltration unit. An air biofilter consists of one or more beds of packing material inoculated with heterotrophic microorganisms capable of degrading the organic contaminant of concern. Waste gases and oxygen are passed through the inoculated packing material, where the microorganisms will degrade the contaminant and release CO{sub 2} + H{sub 2}O. Based on data obtained from a treatability study, a full-scale unit was designed and constructed to be used for treating gasoline vapors generated by a vapor-extraction and groundwater-treatment system at amore » site in California. The unit is composed of two cylindrical reactors with a total packing volume of 3 m{sup 3}. Both reactors are packed with sphagnum moss and inoculated with hydrocarbon-degrading microorganisms of Pseudomonas and Arthrobacter spp. The two reactors are connected in series for air-flow passage. Parallel lines are used for injection of water, nutrients, and buffer to each reactor. Data collected during the startup program have demonstrated an air biofiltration unit with high organic-vapor-removal efficiency.« less

  14. Paleomagnetic investigation of late Quaternary sediments of south San Francisco Bay, California

    USGS Publications Warehouse

    Hillhouse, John W.

    1977-01-01

    Paleomagnetic inclinations of the Late Quaternary sediments of South San Francisco Bay were determined from bore hole samples collected near Dumbarton Bridge. The sediments consist of estuarine muds and nonmarine sand deposits, floored by bedrock of the Mesozoic Franciscan Formation. - Beneath Dumbarton Bridge the entire sedimentary fill is normally polarized; therefore, the fill postdates the Brunhes-Matayama polarity reversal (700,000 y. B.P.). Magnetic time lines such as the Mono Lake excursion (24,000 y. B.P.) and the reversed Blake event (110,000 y B.P.) were not found in this bore hole. In addition to Holocene and modern deposits of San Francisco Bay, an older estuarine unit occurs in the stratigraphic section. The older unit was deposited during a period of high sea level, tentatively correlated with the Sangamon interglacial period. Because evidence of the Blake event is not present in the older estuarine unit, the proposed age of this unit could not be confirmed. Although the Holocene estuarine deposits of South San Francisco Bay carry stable remanent magnetization, a reliable record of geomagnetic secular variation could not be recovered because the water-saturated sdiment was deformed by drilling.

  15. Labeled cutaway line drawing of Shuttle Extravehicular Mobility Unit (EMU)

    NASA Image and Video Library

    1991-05-21

    Labeled cutaway line drawing of the Shuttle extravehicular mobility unit (EMU) identifies its various components and equipment. The portable life support system (PLSS) and protective layers of fabric (thermal micrometeoroid garment (TMG)) incorporated in this extravehicular activity (EVA) space suit are shown.

  16. Labeled cutaway line drawing of Shuttle Extravehicular Mobility Unit (EMU)

    NASA Technical Reports Server (NTRS)

    1991-01-01

    Labeled cutaway line drawing of the Shuttle extravehicular mobility unit (EMU) identifies its various components and equipment. The portable life support system (PLSS) and protective layers of fabric (thermal micrometeoroid garment (TMG)) incorporated in this extravehicular activity (EVA) space suit are shown.

  17. A feasibility study of a microwave water vapor measurement from a space probe along an occultation path

    NASA Technical Reports Server (NTRS)

    Longbothum, R. L.

    1975-01-01

    Stratospheric and mesospheric water vapor measurements were taken using the microwave lines at 22 GHz (22.235 GHz) and 183 GHz (183.31 GHz). The resonant cross sections for both the 22 GHz and the 183 GHz lines were used to model the optical depth of atmospheric water vapor. The range of optical depths seen by a microwave radiometer through the earth's limb was determined from radiative transfer theory. Radiometer sensitivity, derived from signal theory, was compared with calculated optical depths to determine the maximum height to which water vapor can be measured using the following methods: passive emission, passive absorption, and active absorption. It was concluded that measurements using the 22 GHz line are limited to about 50 km whereas the 183 GHz line enables measurements up to and above 100 km for water vapor mixing ratios as low as 0.1 ppm under optimum conditions.

  18. Line shape parameters of the 22-GHz water line for accurate modeling in atmospheric applications

    NASA Astrophysics Data System (ADS)

    Koshelev, M. A.; Golubiatnikov, G. Yu.; Vilkov, I. N.; Tretyakov, M. Yu.

    2018-01-01

    The paper concerns refining parameters of one of the major atmospheric diagnostic lines of water vapor at 22 GHz. Two high resolution microwave spectrometers based on different principles of operation covering together the pressure range from a few milliTorr up to a few Torr were used. Special efforts were made to minimize possible sources of systematic measurement errors. Satisfactory self-consistency of the obtained data was achieved ensuring reliability of the obtained parameters. Collisional broadening and shifting parameters of the line in pure water vapor and in its mixture with air were determined at room temperature. Comparative analysis of the obtained parameters with previous data is given. The speed dependence effect impact on the line shape was evaluated.

  19. Dental unit water lines decontamination with the aid of nanotechnology.

    PubMed

    Paramashivaiah, Rashmi; Prabhuji, M L V; Narayanan, Roopalakshmi

    2016-01-01

    This article reviews the issue of dental unit waterline (DUWL) contamination which affects all the clinical and hospital settings. The contaminating microorganisms commonly isolated from these settings and the most pathogenic among them have serious consequences. Over the years several measures are inculcated for decontamination of water, their advantages and shortcomings have been addressed. Options using nanotechnology which are available in the market are described briefly. A manual and electronic search was conducted. Google and PubMed were searched for relevant material from studies up to 2013. Medical Subject Headings words looked for were "Nanotechnology," "Water purification," and "Biofilms." Reviewed findings were summarized by topic, using the Preferred Reporting Items for Systematic Reviews and Meta-analyses statement for reporting. Seventy articles were shortlisted for articles pertaining to our topic of discussion. A systematic approach was followed by two independent reviewers and included eligibility criteria for study inclusion, data extraction, data synthesis, and drawing of conclusion. Dental waterline contamination is widespread in any type of dental setting having serious implications on clinicians and patients alike, especially elderly and immune-compromised. Hence, international bodies like center for disease and control and American Dental Association have come up with stringent measures for maintenance of water quality. A gamut of procedures has been tried to overcome this problem ranging from chlorinated products, water filters to the usage of distilled water. The use of nanoemulsions, nanofilters, nanomembranes, etc., and their applicability for routine usage is discussed. Biofilm formation in DUWLs is inevitable with the subsequent release of part of microbiota into the otherwise sterile dental settings. These consequences can be quite serious on clinicians and dental patients. Though conventional measures in water decontamination have been partly successful, the quest for more foolproof methods has led to the use of latest technology, i.e., nanotechnology. The most practical option has to be chosen based on the ease of their usage.

  20. 3 CFR - Designation of Officers of the United States Section, International Boundary and Water Commission...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., International Boundary and Water Commission, United States and Mexico To Act as the Commissioner of the United... States and Mexico To Act as the Commissioner of the United States Section Memorandum for the Commissioner of the United States Section, International Boundary and Water Commission, United States and Mexico...

  1. Modelling of deformation of underground tunnel lining, interacting with water-saturated soil

    NASA Astrophysics Data System (ADS)

    Berezhnoi, D. V.; Balafendieva, I. S.; Sachenkov, A. A.; Sekaeva, L. R.

    2016-11-01

    Built finite element method of calculating the deformation of underground tunnel lining, interacting with dry and water-saturated soils. To simulate the interaction between the lining and soils environments, including physical and non-linear, a special "contact" finite element, which allows to consider all cases of interaction between the contacting surfaces. It solved a number of problems of deformation with the ground subway tunnel lining rings.

  2. Water Environment Assessment as an Ecological Red Line Management Tool for Marine Wetland Protection

    PubMed Central

    Zhang, Yinan; Chu, Chunli; Liu, Lei; Xu, Shengguo; Ruan, Xiaoxue; Ju, Meiting

    2017-01-01

    A ‘red line’ was established, identifying an area requiring for ecological protection in Tianjin, China. Within the protected area of the red line area, the Qilihai wetland is an important ecotope with complex ecological functions, although the ecosystem is seriously disturbed due to anthropogenic activities in the surrounding areas. This study assesses the water quality status of the Qilihai wetlands to identify the pollution sources and potential improvements based on the ecological red line policy, to improve and protect the waters of the Qilihai wetlands. An indicator system was established to assess water quality status using single factor evaluation and a comprehensive evaluation method, supported by data from 2010 to 2013. Assessment results show that not all indicators met the requirement of the Environmental Quality Standards for Surface Water (GB3838-2002) and that overall, waters in the Qilihai wetland were seriously polluted. Based on these findings we propose restrictions on all polluting anthropogenic activities in the red line area and implementation of restoration projects to improve water quality. PMID:28767096

  3. In-line thermoelectric module

    DOEpatents

    Pento, Robert; Marks, James E.; Staffanson, Clifford D.

    2000-01-01

    A thermoelectric module with a plurality of electricity generating units each having a first end and a second end, the units being arranged first end to second end along an in-line axis. Each unit includes first and second elements each made of a thermoelectric material, an electrically conductive hot member arranged to heat one side of the first element, and an electrically conductive cold member arranged to cool another side of the first element and to cool one side of the second element. The hot member, the first element, the cold member and the second element are supported in a fixture, are electrically connected respectively to provide an electricity generating unit, and are arranged respectively in positions along the in-line axis. The individual components of each generating unit and the respective generating units are clamped in their in-line positions by a loading bolt at one end of the fixture and a stop wall at the other end of the fixture. The hot members may have a T-shape and the cold members an hourglass shape to facilitate heat transfer. The direction of heat transfer through the hot members may be perpendicular to the direction of heat transfer through the cold members, and both of these heat transfer directions may be perpendicular to the direction of current flow through the module.

  4. Modeling a two-layer flow system at the subarctic, subalpine tree line during snowmelt

    NASA Astrophysics Data System (ADS)

    Leenders, Erica E.; Woo, Ming-Ko

    2002-10-01

    In the subarctic it is common to encounter a two-layer flow system consisting of a porous organic cover overlying frozen or unfrozen mineral soils with much lower hydraulic conductivities. The "simple lumped reservoir parametric," or "semidistributed land-use-based runoff processes" (SLURP), model was adapted to simulate runoff generated by such a flow system from an upland shrub land to an open woodland downslope. A subalpine site in Wolf Creek, Yukon, Canada, was subdivided into two aggregated simulation areas (ASA), each being a unit characterized by a set of parameters. The model computes the vertical water balance and flow generation from several storages, and then routes the water out of the ASA. When applied to the 1999 snowmelt season, the model simulated the very low lateral flow and a large increase in storage in the mineral soil, as was observed in the field. The model was used to assess the sensitivity of the two-layer flow system under a range of temperature, snow cover, and frost conditions. Results show that within the range of possible climatic conditions, the hydrologic system is unlikely to yield significant runoff across the subalpine tree line, but if ground ice is abundant in the soil pores, percolation will be limited and fast flow from the surface layer is enhanced.

  5. 76 FR 19124 - United States Section, Notice of Availability of a Draft Supplemental Environmental Assessment...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-06

    ... INTERNATIONAL BOUNDARY AND WATER COMMISSION, UNITED STATES AND MEXICO United States Section... States Section, International Boundary and Water Commission, United States and Mexico (USIBWC). ACTION..., Environmental Management Division, United States Section, International Boundary and Water Commission; 4171 N...

  6. 33 CFR 151.2040 - What are the mandatory ballast water management requirements for vessels equipped with ballast...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... United States and are bound for ports or places in the United States? 151.2040 Section 151.2040... Water Management for Control of Nonindigenous Species in Waters of the United States § 151.2040 What are... operate in the waters of the United States and are bound for ports or places in the United States? (a) A...

  7. Treatment of silica effluents: ultrafiltration or coagulation-decantation.

    PubMed

    Ndiaye, P I; Moulin, P; Dominguez, L; Millet, J C; Charbit, F

    2004-12-10

    In the electronics industry, the preparation of silicon plates generates effluents that contain a great amount of colloidal silica. Two processes--decantation and ultrafiltration--are studied with in view the treatment of the effluents released by the firm Rockwood Electronic Materials. The feasibility of each of the two processes is studied separately and their operating parameters optimized. Both processes allow the recovery of a great proportion of the initial effluent (over 89%) as transparent and colorless water that can be reused at the start of a line. In view of the results and of the compared advantages and disadvantages of the two processes, ultrafiltration will be selected for the industrial unit.

  8. Geohydrological characterization, water-chemistry, and ground-water flow simulation model of the Sonoma Valley area, Sonoma County, California

    USGS Publications Warehouse

    Farrar, Christopher D.; Metzger, Loren F.; Nishikawa, Tracy; Koczot, Kathryn M.; Reichard, Eric G.; Langenheim, V.E.

    2006-01-01

    The Sonoma Valley, located about 30 miles north of San Francisco, is one of several basins in Sonoma County that use a combination of ground water and water delivered from the Russian River for supply. Over the past 30 years, Sonoma Valley has experienced rapid population growth and land-use changes. In particular, there has been a significant increase in irrigated agriculture, predominantly vineyards. To provide a better understanding of the ground-water/surface-water system in Sonoma Valley, the U.S. Geological Survey compiled and evaluated existing data, collected and analyzed new data, and developed a ground-water flow model to better understand and manage the ground-water system. The new data collected include subsurface lithology, gravity measurements, groundwater levels, streamflow gains and losses, temperature, water chemistry, and stable isotopes. Sonoma Valley is drained by Sonoma Creek, which discharges into San Pablo Bay. The long-term average annual volume of precipitation in the watershed is estimated to be 269,000 acre-feet. Recharge to the ground-water system is primarily from direct precipitation and Sonoma Creek. Discharge from the ground-water system is predominantly outflow to Sonoma Creek, pumpage, and outflow to marshlands and to San Pablo Bay. Geologic units of most importance for groundwater supply are the Quaternary alluvial deposits, the Glen Ellen Formation, the Huichica Formation, and the Sonoma Volcanics. In this report, the ground-water system is divided into three depth-based geohydrologic units: upper (less than 200 feet below land surface), middle (between 200 and 500 feet), and lower (greater than 500 feet). Synoptic streamflow measurements were made along Sonoma Creek and indicate those reaches with statistically significant gains or losses. Changes in ground-water levels in wells were analyzed by comparing historical contour maps with the contour map for 2003. In addition, individual hydrographs were evaluated to assess temporal changes by region. In recent years, pumping depressions have developed southeast of Sonoma and southwest of El Verano. Water-chemistry data for samples collected from 75 wells during 2002-04 indicate that the ground-water quality in the study area generally is acceptable for potable use. The water from some wells, however, contains one or more constituents in excess of the recommended standards for drinking water. The chemical composition of water from creeks, springs, and wells sampled for major ions plot within three groups on a trilinear diagram: mixed-bicarbonate, sodium-mixed anion, and sodium-bicarbonate. An area of saline ground water in the southern part of the Sonoma Valley appears to have shifted since the late 1940s and early 1950s, expanding in one area, but receding in another. Sparse temperature data from wells southwest of the known occurrence of thermal water suggest that thermal water may be present beneath a larger part of the valley than previously thought. Thermal water contains higher concentrations of dissolved minerals than nonthermal waters because mineral solubilities generally increase with temperature. Geohydrologic Characterization, Water-Chemistry, and Ground-Water Flow Simulation Model of the Sonoma Valley Area, Sonoma County, California Oxygen-18 (d18 O) and deuterium (dD) values for water from most wells plot along the global meteoric water line, indicating that recharge primarily is derived from the direct infiltration of precipitation or the infiltration of seepage from creeks. Samples from shallow- and intermediate-depth wells located near Sonoma Creek and (or) in the vicinity of Shellville plot to the right of the global meteoric water line, indicating that these waters are partly evaporated. The d18 O and dD composition of water from sampled wells indicates that water from wells deeper than 200 feet is isotopically lighter (more negative) than water from wells less than 200 feet deep, possibly indicating that older ground wate

  9. Airborne and Ground Electrical Surveys for Subsurface Mapping of the Arbuckle Aquifer, Central Oklahoma

    NASA Astrophysics Data System (ADS)

    Smith, D.; Smith, B. D.; Blome, C. D.; Osborn, N.

    2008-12-01

    Airborne and ground electrical surveys have been conducted to map the subsurface hydrogeologic character of the Arbuckle-Simpson aquifer in south central Oklahoma. An understanding of the geologic framework and hydrogeologic characteristics is necessary to evaluate groundwater flow through the highly faulted, structurally complex, carbonate aquifer. Results from this research will further understanding of the aquifer and will assist in managing the water resources of the region. The major issues include water quality, the allocation of water rights, and the potential impacts of pumping on springs and stream. Four areas in the Hunton anticline area, with distinctly different geology, were flown with a frequency domain helicopter electromagnetic system (HEM) in March, 2007. Ground electrical studies include dc resistivity imaging and natural field audiomagnetotelluric (AMT), and magnetotelluric (MT) surveys. The HEM resistivity and total field magnetic survey was flown in four blocks, A through D, mostly with a line spacing of 400 m. Block A extends from the Chickasaw National Recreational Area (CHIC) to Mill Creek on the west side of the anticline. The surface geology of this block is mostly dolomitic limestone of the Arbuckle Group that is in fault contact with younger Paleozoic clastic rocks. The flight line spacing was 800 meters in the western half of the block and 400 meters in the eastern part. Airborne magnetic data indicate that the Sulphur fault bends south to merge with the Mill Creek fault which substantiates an earlier hypothesis first made from interpretation of gravity data. Block B, located on the north side of the anticline consists of mostly of Arbuckle and Simpson Group rocks. Block C, covering most of the Clarita horst on the east side of the anticline, consists of the Upper Ordovician to the Lower Pennsylvanian shales. Block D, which was flown to include a deep test well site at Spears ranch, consisted of eight lines spaced at 400 meters. The HEM data are being used to more precisely locate faults, refine the lithostratigraphic units, and to map the depth and extent of shallow epikarst. The MT and AMT data revealed deep structural contacts and a transition between fresh and highly mineralized ground water between springs in the CHIC. The dc resistivity survey has greatly helped in mapping major faults both within dolomitic limestone and clastic units. Ground resistivity surveys also suggest that, in places, the faults within limestone are zones of lower resistivity and map low resistivity surficial epikarst a several meters thick. Ground penetrometer data also has been used to define the depth extent of epikarst in selected areas and the data correlate well with the dc resistivity and HEM resistivity depth sections.

  10. Cost-effectiveness of a quality improvement programme to reduce central line-associated bloodstream infections in intensive care units in the USA

    PubMed Central

    Herzer, Kurt R; Niessen, Louis; Constenla, Dagna O; Ward, William J; Pronovost, Peter J

    2014-01-01

    Objective To assess the cost-effectiveness of a multifaceted quality improvement programme focused on reducing central line-associated bloodstream infections in intensive care units. Design Cost-effectiveness analysis using a decision tree model to compare programme to non-programme intensive care units. Setting USA. Population Adult patients in the intensive care unit. Costs Economic costs of the programme and of central line-associated bloodstream infections were estimated from the perspective of the hospital and presented in 2013 US dollars. Main outcome measures Central line-associated bloodstream infections prevented, deaths averted due to central line-associated bloodstream infections prevented, and incremental cost-effectiveness ratios. Probabilistic sensitivity analysis was performed. Results Compared with current practice, the programme is strongly dominant and reduces bloodstream infections and deaths at no additional cost. The probabilistic sensitivity analysis showed that there was an almost 80% probability that the programme reduces bloodstream infections and the infections’ economic costs to hospitals. The opportunity cost of a bloodstream infection to a hospital was the most important model parameter in these analyses. Conclusions This multifaceted quality improvement programme, as it is currently implemented by hospitals on an increasingly large scale in the USA, likely reduces the economic costs of central line-associated bloodstream infections for US hospitals. Awareness among hospitals about the programme's benefits should enhance implementation. The programme's implementation has the potential to substantially reduce morbidity, mortality and economic costs associated with central line-associated bloodstream infections. PMID:25256190

  11. Results from the EPL monkey-pod experiment conducted as part of the 1974 NASA/Ames shuttle CVT-2

    NASA Technical Reports Server (NTRS)

    Rahlmann, D. F.; Kodama, A. M.; Mains, R. C.; Pace, N.

    1974-01-01

    The participation of the Environmental Physiology Laboratory (EPL) in the general purpose laboratory concept verification test 3 is documented. The EPL Monkey-Pod Experiment was designed to incorporate a 10-12 kg, pig tailed monkey, Macaca nemestrina, into the pod and measure the physiological responses of the animal continuously. Four major elements comprise the EPL Monkey-Pod Experiment System: (1) a fiberglass pod containing the instrumented monkey plus feeder and watering devices, (2) an inner console containing the SKYLAB mass spectrometer with its associated valving and electronic controls, sensing, control and monitoring units for lower body negative pressure, feeder activity, waterer activity, temperatures, and gas metabolism calibration, (3) an umbilical complex comprising gas flow lines and electrical cabling between the inner and outer console and (4) an outer console in principle representing the experiment support to be provided from general spacecraft sources.

  12. Plans for a sensitivity analysis of bridge-scour computations

    USGS Publications Warehouse

    Dunn, David D.; Smith, Peter N.

    1993-01-01

    Plans for an analysis of the sensitivity of Level 2 bridge-scour computations are described. Cross-section data from 15 bridge sites in Texas are modified to reflect four levels of field effort ranging from no field surveys to complete surveys. Data from United States Geological Survey (USGS) topographic maps will be used to supplement incomplete field surveys. The cross sections are used to compute the water-surface profile through each bridge for several T-year recurrence-interval design discharges. The effect of determining the downstream energy grade-line slope from topographic maps is investigated by systematically varying the starting slope of each profile. The water-surface profile analyses are then used to compute potential scour resulting from each of the design discharges. The planned results will be presented in the form of exceedance-probability versus scour-depth plots with the maximum and minimum scour depths at each T-year discharge presented as error bars.

  13. Paper area density measurement from forward transmitted scattered light

    DOEpatents

    Koo, Jackson C.

    2001-01-01

    A method whereby the average paper fiber area density (weight per unit area) can be directly calculated from the intensity of transmitted, scattered light at two different wavelengths, one being a non-absorpted wavelength. Also, the method makes it possible to derive the water percentage per fiber area density from a two-wavelength measurement. In the optical measuring technique optical transmitted intensity, for example, at 2.1 microns cellulose absorption line is measured and compared with another scattered, optical transmitted intensity reference in the nearby spectrum region, such as 1.68 microns, where there is no absorption. From the ratio of these two intensities, one can calculate the scattering absorption coefficient at 2.1 microns. This absorption coefficient at this wavelength is, then, experimentally correlated to the paper fiber area density. The water percentage per fiber area density can be derived from this two-wavelength measurement approach.

  14. Results from the EPL monkey-pod flight experiments conducted aboard the NASA/Ames CV-990, May 1976

    NASA Technical Reports Server (NTRS)

    Rahlmann, D. F.; Kodama, A. M.; Mains, R. C.; Pace, N.

    1976-01-01

    The participation of the Environmental Physiology Laboratory (EPL) in the general purpose laboratory concept verification test 3 is documented. The EPL Monkey-Pod Experiment was designed to incorporate a 10-12 kg, pig tailed monkey, Macaca nemestrina, into the pod and measure the physiological responses of the animal continously. Four major elements comprise the EPL Monkey-Pod Experiment System: (1) a fiberglass pod containing the instrumented monkey plus feeder and watering devices, (2) an inner console containing the SKYLAB mass spectrometer with its associated valving and electronic controls, sensing, control and monitoring units for lower body negative pressure, feeder activity, waterer activity, temperatures, and gas metabolism calibration, (3) an umbilical complex comprising gas flow lines and electrical cabling between the inner and outer console and (4) an outer console in principle representing the experiment support to be provided from general space craft sources.

  15. Multiresidue analysis of 24 Water Framework Directive priority substances by on-line solid phase extraction-liquid chromatography tandem mass spectrometry in environmental waters.

    PubMed

    Rubirola, Adrià; Boleda, Mª Rosa; Galceran, Mª Teresa

    2017-04-14

    This paper reports the development of a fully multiresidue and automated on-line solid phase extraction (SPE) - liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the determination of 24 priority substances (PS) belonging to different classes (pesticides, hormones or pharmaceuticals) included in the Directive 2013/39/UE and the recent Watch List (Decision 2015/495) in water samples (drinking water, surface water, and effluent wastewaters). LC-MS/MS conditions and on-line SPE parameters such as sorbent type, sample and wash volumes were optimized. The developed method is highly sensitive (limits of detection between 0.1 and 1.4ngL -1 ) and precise (relative standard deviations lower than 8%). As part of the method validation studies, linearity, accuracy and matrix effects were assessed. The main advantage of this method over traditional off-line procedures is the minimization of tedious sample preparation increasing productivity and sample throughput. The optimized method was applied to the analysis of water samples and the results revealed the presence of 16 PS in river water and effluent water of wastewater treatment plants. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Engineering refinements to overcome default nuclide regulatory constraints

    NASA Astrophysics Data System (ADS)

    Finn, R.; Capitelli, P.; Sheh, Y.; Lom, C.; Graham, M.; Germain, J. St.

    2005-12-01

    The "classical" positron emitting radionuclides include oxygen-15, nitrogen-13 and carbon-11 which possess unique properties for medical imaging. They are radionuclides of the fundamental elements of biological matter. They each possess short half-lives which allow their use in designed radiotracers for clinical investigations with minimal risk and they are readily able to be produced in sufficient activities by low energy nuclear reactions. At present several accelerator manufacturers offer production packages for these radionuclides emphasizing targetry with consideration of the cyclotron extracted energies for nuclide production and on-line chemistry systems for the continuous production of specific precursors or radiotracers. Following the installation and acceptance of the MSKCC TR 19/9 Cyclotron, our experience with the procured chemistry module for the preparation of oxygen-15 labeled water has forced us to examine the design and the operation of the synthetic unit with a view toward the state of New York's regulations addressing the environmental pollution from radioactive materials. The chemistry module was refined with subtle modifications to the chemistry procedure/unit and our experience with the unit is presented as an example of our approach to insure regulatory compliance.

  17. Relationship between the line of density anomaly and the lines of melting, crystallization, cavitation, and liquid spinodal in coarse-grained water models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu, Jibao; Molinero, Valeria, E-mail: Valeria.Molinero@utah.edu; Chakravarty, Charusita

    2016-06-21

    Liquid water has several anomalous properties, including a non-monotonous dependence of density with temperature and an increase of thermodynamic response functions upon supercooling. Four thermodynamic scenarios have been proposed to explain the anomalies of water, but it is not yet possible to decide between them from experiments because of the crystallization and cavitation of metastable liquid water. Molecular simulations provide a versatile tool to study the anomalies and phase behavior of water, assess their agreement with the phenomenology of water under conditions accessible to experiments, and provide insight into the behavior of water in regions that are challenging to probemore » in the laboratory. Here we investigate the behavior of the computationally efficient monatomic water models mW and mTIP4P/2005{sup REM}, with the aim of unraveling the relationships between the lines of density extrema in the p-T plane, and the lines of melting, liquid-vapor spinodal and non-equilibrium crystallization and cavitation. We focus particularly on the conditions for which the line of density maxima (LDM) in the liquid emerges and disappears as the pressure is increased. We find that these models present a retracing LDM, same as previously found for atomistic water models and models of other tetrahedral liquids. The low-pressure end of the LDM occurs near the pressure of maximum of the melting line, a feature that seems to be general to models that produce tetrahedrally coordinated crystals. We find that the mW water model qualitatively reproduces several key properties of real water: (i) the LDM is terminated by cavitation at low pressures and by crystallization of ice I{sub h} at high pressures, (ii) the LDM meets the crystallization line close to the crossover in crystallization from ice I{sub h} to a non-tetrahedral four-coordinated crystal, and (iii) the density of the liquid at the crossover in crystallization from ice I{sub h} to a four-coordinated non-tetrahedral crystal coincides with the locus of maximum in diffusivity as a function of pressure. The similarities in equilibrium and non-equilibrium phase behavior between the mW model and real water provide support to the quest to find a compressibility extremum, and determine whether it presents a maximum, in the doubly metastable region.« less

  18. Relationship between the line of density anomaly and the lines of melting, crystallization, cavitation, and liquid spinodal in coarse-grained water models.

    PubMed

    Lu, Jibao; Chakravarty, Charusita; Molinero, Valeria

    2016-06-21

    Liquid water has several anomalous properties, including a non-monotonous dependence of density with temperature and an increase of thermodynamic response functions upon supercooling. Four thermodynamic scenarios have been proposed to explain the anomalies of water, but it is not yet possible to decide between them from experiments because of the crystallization and cavitation of metastable liquid water. Molecular simulations provide a versatile tool to study the anomalies and phase behavior of water, assess their agreement with the phenomenology of water under conditions accessible to experiments, and provide insight into the behavior of water in regions that are challenging to probe in the laboratory. Here we investigate the behavior of the computationally efficient monatomic water models mW and mTIP4P/2005(REM), with the aim of unraveling the relationships between the lines of density extrema in the p-T plane, and the lines of melting, liquid-vapor spinodal and non-equilibrium crystallization and cavitation. We focus particularly on the conditions for which the line of density maxima (LDM) in the liquid emerges and disappears as the pressure is increased. We find that these models present a retracing LDM, same as previously found for atomistic water models and models of other tetrahedral liquids. The low-pressure end of the LDM occurs near the pressure of maximum of the melting line, a feature that seems to be general to models that produce tetrahedrally coordinated crystals. We find that the mW water model qualitatively reproduces several key properties of real water: (i) the LDM is terminated by cavitation at low pressures and by crystallization of ice Ih at high pressures, (ii) the LDM meets the crystallization line close to the crossover in crystallization from ice Ih to a non-tetrahedral four-coordinated crystal, and (iii) the density of the liquid at the crossover in crystallization from ice Ih to a four-coordinated non-tetrahedral crystal coincides with the locus of maximum in diffusivity as a function of pressure. The similarities in equilibrium and non-equilibrium phase behavior between the mW model and real water provide support to the quest to find a compressibility extremum, and determine whether it presents a maximum, in the doubly metastable region.

  19. RESOLVE Project

    NASA Technical Reports Server (NTRS)

    Parker, Ray; Coan, Mary; Cryderman, Kate; Captain, Janine

    2013-01-01

    The RESOLVE project is a lunar prospecting mission whose primary goal is to characterize water and other volatiles in lunar regolith. The Lunar Advanced Volatiles Analysis (LAVA) subsystem is comprised of a fluid subsystem that transports flow to the gas chromatograph - mass spectrometer (GC-MS) instruments that characterize volatiles and the Water Droplet Demonstration (WDD) that will capture and display water condensation in the gas stream. The LAVA Engineering Test Unit (ETU) is undergoing risk reduction testing this summer and fall within a vacuum chamber to understand and characterize component and integrated system performance. Testing of line heaters, printed circuit heaters, pressure transducers, temperature sensors, regulators, and valves in atmospheric and vacuum environments was done. Test procedures were developed to guide experimental tests and test reports to analyze and draw conclusions from the data. In addition, knowledge and experience was gained with preparing a vacuum chamber with fluid and electrical connections. Further testing will include integrated testing of the fluid subsystem with the gas supply system, near-infrared spectrometer, WDD, Sample Delivery System, and GC-MS in the vacuum chamber. This testing will provide hands-on exposure to a flight forward spaceflight subsystem, the processes associated with testing equipment in a vacuum chamber, and experience working in a laboratory setting. Examples of specific analysis conducted include: pneumatic analysis to calculate the WDD's efficiency at extracting water vapor from the gas stream to form condensation; thermal analysis of the conduction and radiation along a line connecting two thermal masses; and proportional-integral-derivative (PID) heater control analysis. Since LAVA is a scientific subsystem, the near-infrared spectrometer and GC-MS instruments will be tested during the ETU testing phase.

  20. Study of magnetic fields from power-frequency current on water lines.

    PubMed

    Lanera, D; Zapotosky, J E; Colby, J A

    1997-01-01

    The magnetic fields from power-frequency current flowing on water lines were investigated in a new approach that involved an area-wide survey in a small town. Magnetic fields were measured outside the residence under power cables and over water lines, and each residence was characterized as to whether it received water from a private well or the municipal water system. The magnetic field data revealed two statistical modes when they were related to water supply type. The data also showed that in the case of the high mode, the magnetic field remained constant along the line formed by power drop wires, at the back of the house, and the water hookup service, in front of the house, all the way to the street. The patterns are explained by the coincidence of measurement points and the presence of net current flowing on power mains, power drop conductors, residential plumbing, water service hookups, and water mains. These patterns, together with other characteristics of this magnetic field source, such as the gradual spatial fall-off of this field and the presence of a constant component in the time sequence, portray a magnetic field more uniform and constant in the residential environment than has been thought to exist. Such characteristics make up for the weakness of the source and make net current a significant source of exposure in the lives of individuals around the house, when human exposure to magnetic fields is assumed to be a cumulative effect over time. This, together with the bimodal statistical distribution of the residential magnetic field (related to water supply type), presents opportunities for retrospective epidemiological analysis. Water line type and its ability to conduct power-frequency current can be used as the historical marker for a bimodal exposure inference, as Wertheimer et al. have shown.

  1. Spectroscopic and thermodynamic properties of molecular hydrogen dissolved in water at pressures up to 200 MPa

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borysow, Jacek, E-mail: jborysow@mtu.edu; Rosso, Leonardo del; Celli, Milva

    2014-04-28

    We have measured the Raman Q-branch of hydrogen in a solution with water at a temperature of about 280 K and at pressures from 20 to 200 MPa. From a least-mean-square fitting analysis of the broad Raman Q-branch, we isolated the contributions from the four lowest individual roto-vibrational lines. The vibrational lines were narrower than the pure rotational Raman lines of hydrogen dissolved in water measured previously, but significantly larger than in the gas. The separations between these lines were found to be significantly smaller than in gaseous hydrogen and their widths were slightly increasing with pressure. The lines weremore » narrowing with increasing rotational quantum number. The Raman frequencies of all roto-vibrational lines were approaching the values of gas phase hydrogen with increasing pressure. Additionally, from the comparison of the integrated intensity signal of Q-branch of hydrogen to the integrated Raman signal of the water bending mode, we have obtained the concentration of hydrogen in a solution with water along the 280 K isotherm. Hydrogen solubility increases slowly with pressure, and no deviation from a smooth behaviour was observed, even reaching thermodynamic conditions very close to the transition to the stable hydrogen hydrate. The analysis of the relative hydrogen concentration in solution on the basis of a simple thermodynamic model has allowed us to obtain the molar volume for the hydrogen gas/water solution. Interestingly, the volume relative to one hydrogen molecule in solution does not decrease with pressure and, at high pressure, is larger than the volume pertinent to one molecule of water. This is in favour of the theory of hydrophobic solvation, for which a larger and more stable structure of the water molecules is expected around a solute molecule.« less

  2. The Depletion of Water During Dispersal of Planet-forming Disk Regions

    NASA Astrophysics Data System (ADS)

    Banzatti, A.; Pontoppidan, K. M.; Salyk, C.; Herczeg, G. J.; van Dishoeck, E. F.; Blake, G. A.

    2017-01-01

    We present a new velocity-resolved survey of 2.9 μm spectra of hot H2O and OH gas emission from protoplanetary disks, obtained with the Cryogenic Infrared Echelle Spectrometer at the VLT (R ˜ 96,000). With the addition of archival Spitzer-IRS spectra, this is the most comprehensive spectral data set of water vapor emission from disks ever assembled. We provide line fluxes at 2.9-33 μm that probe from the dust sublimation radius at ˜0.05 au out to the region of the water snow line. With a combined data set for 55 disks, we find a new correlation between H2O line fluxes and the radius of CO gas emission, as measured in velocity-resolved 4.7 μm spectra (R {}{co}), which probes molecular gaps in inner disks. We find that H2O emission disappears from 2.9 μm (hotter water) to 33 μm (colder water) as {R}{co} increases and expands out to the snow line radius. These results suggest that the infrared water spectrum is a tracer of inside-out water depletion within the snow line. It also helps clarify an unsolved discrepancy between water observations and models by finding that disks around stars of {M}\\star > 1.5 {M}⊙ generally have inner gaps with depleted molecular gas content. We measure radial trends in H2O, OH, and CO line fluxes that can be used as benchmarks for models to study the chemical composition and evolution of planet-forming disk regions at 0.05-20 au. We propose that JWST spectroscopy of molecular gas may be used as a probe of inner disk gas depletion, complementary to the larger gaps and holes detected by direct imaging and by ALMA.

  3. Spectroscopic and thermodynamic properties of molecular hydrogen dissolved in water at pressures up to 200 MPa.

    PubMed

    Borysow, Jacek; del Rosso, Leonardo; Celli, Milva; Moraldi, Massimo; Ulivi, Lorenzo

    2014-04-28

    We have measured the Raman Q-branch of hydrogen in a solution with water at a temperature of about 280 K and at pressures from 20 to 200 MPa. From a least-mean-square fitting analysis of the broad Raman Q-branch, we isolated the contributions from the four lowest individual roto-vibrational lines. The vibrational lines were narrower than the pure rotational Raman lines of hydrogen dissolved in water measured previously, but significantly larger than in the gas. The separations between these lines were found to be significantly smaller than in gaseous hydrogen and their widths were slightly increasing with pressure. The lines were narrowing with increasing rotational quantum number. The Raman frequencies of all roto-vibrational lines were approaching the values of gas phase hydrogen with increasing pressure. Additionally, from the comparison of the integrated intensity signal of Q-branch of hydrogen to the integrated Raman signal of the water bending mode, we have obtained the concentration of hydrogen in a solution with water along the 280 K isotherm. Hydrogen solubility increases slowly with pressure, and no deviation from a smooth behaviour was observed, even reaching thermodynamic conditions very close to the transition to the stable hydrogen hydrate. The analysis of the relative hydrogen concentration in solution on the basis of a simple thermodynamic model has allowed us to obtain the molar volume for the hydrogen gas/water solution. Interestingly, the volume relative to one hydrogen molecule in solution does not decrease with pressure and, at high pressure, is larger than the volume pertinent to one molecule of water. This is in favour of the theory of hydrophobic solvation, for which a larger and more stable structure of the water molecules is expected around a solute molecule.

  4. Spectroscopic and thermodynamic properties of molecular hydrogen dissolved in water at pressures up to 200 MPa

    NASA Astrophysics Data System (ADS)

    Borysow, Jacek; del Rosso, Leonardo; Celli, Milva; Moraldi, Massimo; Ulivi, Lorenzo

    2014-04-01

    We have measured the Raman Q-branch of hydrogen in a solution with water at a temperature of about 280 K and at pressures from 20 to 200 MPa. From a least-mean-square fitting analysis of the broad Raman Q-branch, we isolated the contributions from the four lowest individual roto-vibrational lines. The vibrational lines were narrower than the pure rotational Raman lines of hydrogen dissolved in water measured previously, but significantly larger than in the gas. The separations between these lines were found to be significantly smaller than in gaseous hydrogen and their widths were slightly increasing with pressure. The lines were narrowing with increasing rotational quantum number. The Raman frequencies of all roto-vibrational lines were approaching the values of gas phase hydrogen with increasing pressure. Additionally, from the comparison of the integrated intensity signal of Q-branch of hydrogen to the integrated Raman signal of the water bending mode, we have obtained the concentration of hydrogen in a solution with water along the 280 K isotherm. Hydrogen solubility increases slowly with pressure, and no deviation from a smooth behaviour was observed, even reaching thermodynamic conditions very close to the transition to the stable hydrogen hydrate. The analysis of the relative hydrogen concentration in solution on the basis of a simple thermodynamic model has allowed us to obtain the molar volume for the hydrogen gas/water solution. Interestingly, the volume relative to one hydrogen molecule in solution does not decrease with pressure and, at high pressure, is larger than the volume pertinent to one molecule of water. This is in favour of the theory of hydrophobic solvation, for which a larger and more stable structure of the water molecules is expected around a solute molecule.

  5. Framework for regional synthesis of water-quality data for the glacial aquifer system in the United States

    USGS Publications Warehouse

    Warner, Kelly L.; Arnold, Terri L.

    2005-01-01

    The glacial aquifer system is the largest principal aquifer in aerial extent and ground-water use for public supply in the United States. A principal aquifer is defined as a regionally extensive aquifer or aquifer system that has the potential to be used as a source of potable water (U.S. Geological Survey, 2003). Multiple aquifers often are grouped into large, extensive aquifer systems such as the glacial aquifer system. The glacial aquifer system is considered here to include all unconsolidated aquifers above bedrock north of the line of continental glaciation throughout the country (fig. 1). Total withdrawals from the glacial aquifer system were 3,560 million gallons per day in 2000, which constitutes almost 5 percent of total withdrawals from all aquifers in the United States (Maupin and Barber, 2005). Approximately 41 million people relied on the glacial aquifer for public supply and domestic use in 2000. The U.S. Geological Survey National Water-Quality Assessment (NAWQA) Program began assessing the glacial aquifer system in 1991. The assessment of water-quality data on a regional scale, such as the glacial aquifer system, is coincident with the regional framework established by the Regional Aquifer-System Analysis Program (RASA) (Sun and others, 1997). From 1978 to 1995, the RASA Program systematically evaluated 25 of the Nation's most important groundwater systems including studies in the glacial aquifer system in the northeast, Midwest, and northern Midwest United States. The NAWQA Program is building on the work of the RASA Program to study the water quality of 16 of the most important ground-water systems (Lapham and others, 2005). Over 1,700 water-quality samples have been collected by the NAWQA Program from 1991 to 2004 to assess the glacial aquifer system. This large data set is unique in that the samples have been collected using a consistent sampling protocol, and multiple nested samples. The nested samples address the recently recharged shallow ground water, deeper water from principal aquifers often used for domestic supply, and source water used for public supplies within the glacial aquifer system. Information concerning the NAWQA Program including study unit boundaries is shown in figure 1 (Lapham and others, 2005). A framework for comparison of water quality across the glacial aquifer system has been developed based on two primary characteristics: intrinsic susceptibility and vulnerability. Intrinsic susceptibility, which is a measure of the ease at which water enters and moves through aquifer material, is a characteristic of the aquifer and overlying material and of the hydrologic conditions. Intrinsic susceptibility is independent of the chemical characteristics of the contaminant and its sources. In this way, intrinsic susceptibility assessments do not target specific natural or anthropogenic sources of contamination but instead consider only the physical factors affecting the flow of water to, and through the ground-water resource (Focazio and others, 2002). On a regional scale, intrinsic susceptibility is represented by the spatial distribution of fine- or coarse-grained material at the land surface, and the physical setting of the aquifer system. Vulnerability, which is a function of both intrinsic susceptibility and the proximity and characteristics of contaminant sources, includes consideration of features related to anthropogenic sources of contaminants, such as the character of the upgradient land use (for example, urban, agricultural, undeveloped, and others); as well as features related to natural sources of contaminants, such as the mineralogy of the aquifer material or the geochemical conditions within the aquifer system. The framework helps categorize this large region into areas of similar hydrogeologic characteristics for which water quality can be compared. The purpose of this report is to describe this framework and how it will be used for regional synthesis of water-quality da

  6. A Near-Road Modeling System for Community-Scale Assessments of Traffic-Related AirPollution in the United States

    EPA Science Inventory

    The Community Line Source (C-LINE) modeling system estimates emissions and dispersion of toxic air pollutants for roadways within the continental United States. It accesses publicly available traffic and meteorological datasets, and is optimized for use on community-sized areas (...

  7. A rootstock provides water conservation for a grafted commercial tomato (Solanum lycopersicum L.) line in response to mild-drought conditions: a focus on vegetative growth and photosynthetic parameters.

    PubMed

    Nilsen, Erik T; Freeman, Joshua; Grene, Ruth; Tokuhisa, James

    2014-01-01

    The development of water stress resistant lines of commercial tomato by breeding or genetic engineering is possible, but will take considerable time before commercial varieties are available for production. However, grafting commercial tomato lines on drought resistant rootstock may produce drought tolerant commercial tomato lines much more rapidly. Due to changing climates and the need for commercial production of vegetables in low quality fields there is an urgent need for stress tolerant commercial lines of vegetables such as tomato. In previous observations we identified a scion root stock combination ('BHN 602' scion grafted onto 'Jjak Kkung' rootstock hereafter identified as 602/Jjak) that had a qualitative drought-tolerance phenotype when compared to the non-grafted line. Based on this initial observation, we studied photosynthesis and vegetative above-ground growth during mild-drought for the 602/Jjak compared with another scion-rootstock combination ('BHN 602' scion grafted onto 'Cheong Gang' rootstock hereafter identified as 602/Cheong) and a non-grafted control. Overall above ground vegetative growth was significantly lower for 602/Jjak in comparison to the other plant lines. Moreover, water potential reduction in response to mild drought was significantly less for 602/Jjak, yet stomatal conductance of all plant-lines were equally inhibited by mild-drought. Light saturated photosynthesis of 602/Jjak was less affected by low water potential than the other two lines as was the % reduction in mesophyll conductance. Therefore, the Jjak Kkung rootstock caused aboveground growth reduction, water conservation and increased photosynthetic tolerance of mild drought. These data show that different rootstocks can change the photosynthetic responses to drought of a high yielding, commercial tomato line. Also, this rapid discovery of one scion-rootstock combination that provided mild-drought tolerance suggests that screening more scion-rootstock combination for stress tolerance may rapidly yield commercially viable, stress tolerant lines of tomato.

  8. Saltwater-barrier line in Florida : concepts, considerations, and site examples

    USGS Publications Warehouse

    Hughes, Jerry L.

    1979-01-01

    Construction of canals and enlargement of streams in Florida has been mostly to alleviate impact of floods and to drain wetlands for development. Land drainage and heavy pumpage from coastal water-table aquifers has degraded potable ground and surface water with saltwater. Control of saltwater intrusion is possible through implementation of certain hydrologic principles. State of Florida statute 373.033 provides for a saltwater-barrier line in areas of saltwater intrusion along canals. A saltwater-barrier line is defined as the allowable landward limit that a canal shall be constructed or enlarged or a stream deepened or enlarged without a salinity-control structure seaward of the saltwater-barrier line. The salinity control structure controls saltwater intrusion along a surface-water channel and assists in controlling saltwater intrusion into shallow aquifers. This report briefly reviews the fundamentals of saltwater intrusion in surface-water channels and associated coastal aquifers, describes the effects of established saltwater-barrier lines in Florida, and gives a history of the use and benefits of salinity-control structures. (Woodard-USGS).

  9. A-E Services to Perform a Cathodic Protection Survey of the Bulk Fuel Terminals at N.S.C. Pearl Harbor, Hawaii. Volume I.

    DTIC Science & Technology

    1982-06-01

    20) From VC-D to VC-E a. 8" Avgas Line - Coated Steel (21) From FC -E to Victor Dock #1 a. 12" Avgas Line - Coated Steel (22) From Air Force Scraper...14. Bldg. S776 3" Ballast Line to VC-2 - 775 3" Ballast Line to Loading Rack - 775 15. 6" Water Line, 10’ N of Bldg. S776 - 745 6" AFFF Line, N of...S776 3" Ballast line to VC-2 - 740 - 775 35 3" Ballast line to Loading Rack - 740 - 775 35 15. 6" Water line 10’ N of Bldg. S776 - 710 - 745 35 6" AFFF

  10. Dual-tracer method to estimate coral reef response to a plume of chemically modified seawater

    NASA Astrophysics Data System (ADS)

    Maclaren, J. K.; Caldeira, K.

    2013-12-01

    We present a new method, based on measurement of seawater samples, to estimate the response of a reef ecosystem to a plume of an additive (for example, a nutrient or other chemical). In the natural environment, where there may be natural variability in concentrations, it can be difficult to distinguish between changes in concentrations that would occur naturally and changes in concentrations that result from a chemical addition. Furthermore, in the unconfined natural environment, chemically modified water can mix with waters that have not been modified, making it difficult to distinguish between effects of dilution and effects of chemical fluxes or transformations. We present a dual-tracer method that extracts signals from observations that may be affected by both natural variability and dilution. In this dual-tracer method, a substance (in our example case, alkalinity) is added to the water in known proportion to a passive conservative tracer (in our example case, Rhodamine WT dye). The resulting plume of seawater is allowed to flow over the study site. Two transects are drawn across the plume at the front and back of the study site. If, in our example, alkalinity is plotted as a function of dye concentration for the front transect, the slope of the resulting mixing line is the ratio of alkalinity to dye in the added fluid. If a similar mixing line is measured and calculated for the back transect, the slope of this mixing line will indicate the amount of added alkalinity that remains in the water flowing out of the study site per unit of added dye. The ratio of the front and back slopes indicates the fraction of added alkalinity that was taken up by the reef. The method is demonstrated in an experiment performed on One Tree Reef (Queensland, Australia) aimed at showing that ocean acidification is already affecting coral reef growth. In an effort to chemically reverse some of the changes to seawater chemistry that have occurred over the past 200 years, we added sodium hydroxide to increase alkalinity in the plume and controlled for dilution with Rhodamine WT dye. Preliminary data will be presented and analyzed using the approach described above.

  11. Seismic Reflection Characteristic and Structure Unit Division of Nanwei Uplift in the Nansha Waters, South China Sea

    NASA Astrophysics Data System (ADS)

    Guo, L.; Zhan, W.; Yao, Y.

    2016-12-01

    Nanwei uplift is located in the continent-ocean transition zone at the southern margin of the South China Sea (SCS). It has the structural characteristics in typical passive margin models. Attributed to squeezing action, the anticline and faulted anticline structure were well developed since Oligocene. The development of organic reef and marine mudstone deposit indicated the drifting and subsidence stage. In this area, the structural evolution is not only related to the dynamic systems of rifting, basin spreading and expansion ending, but also to the collisions between different plates. Meanwhile, a large number of continental margin rifting basins with rich oil and gas resources developed in Nanwei uplift. It is meaningful to analyze the characteristics of seismic reflection waves. Also, two main structural unit were divided for studying the special structures and stratigraphic features in this paper. Two high-resolution single-channel seismic Line Nan-1 and Line Nan-2 in the Nansha Waters, acquired by the trial vessel "Shiyan 2" of the South China Sea Institute of Oceanology in 2013, is interpreted and analyzed in this study. The profiles show that there are a lot of normal fault half-garben systems and depressions in NE direction. Five seismic interfaces have been distinguished, named T0,T3,T4,T5 and Tg respectively. It corresponds to different regional unconformities in different geological age which indicated the characteristics of regional tectonics. On the basis of tectonic shape and previous geophysical data, it is believed that the Nanwei uplift zone is mainly composed of two structural units, the southern subsidence belt and northern buried volcanic uplift belt. The general range of zoning is also discussed in this paper. It is considered that the buried volcanic uplift belt mainly involved the marginal area along the southern ocean basin from 63-72 km wide in SE direction, the neighboring subsidence belt in rifting stage is parallel to the buried volcanic uplift belt with 57.5-128 km wide. In addition, the epicenter distributions of sporadic and larger than 4 magnitude earthquakes suggest that the entire Nanwei uplift is still a relatively stable tectonic activity zone, the crustal stability is good.

  12. 40 CFR 63.1568 - What are my requirements for HAP emissions from sulfur recovery units?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... emissions from sulfur recovery units? 63.1568 Section 63.1568 Protection of Environment ENVIRONMENTAL... Petroleum Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Catalytic Cracking Units, Catalytic Reforming Units, Sulfur Recovery Units, and Bypass Lines § 63.1568 What...

  13. Effect of 0.2% chlorhexidine on microbial and fungal contamination of dental unit waterlines

    PubMed Central

    Agahi, Raha Habib; Hashemipour, Maryam Alsadat; Kalantari, Mahsa; Ayatollah-Mosavi, Amin; Aghassi, Hossein; Nassab, Amir Hossein Gandjalikhan

    2014-01-01

    Background: It is known that dental unit waterline can be a source of infection. The aim of this study was to evaluate the efficacy of a mouthwash, chlorhexidine, in controlling microbial and fungal contamination of dental unit waterlines. Materials and Methods: In the present experimental study, the water in high-speed handpieces and air/water syringes of 35 dental units in a dental school was investigated microbiologically. Five of the units and one tap water served as controls; 100-200-mL water samples were collected aseptically in sterile containers in the morning after a 2-min purge. Water reservoir bottles were emptied and 50 mL of 0.2% chlorhexidine mouthwash was introduced into the tank. Then the water syringe was used to flush the waterline until the pink-colored chlorhexidine was observed to flow from the water syringe. Before the next day's session and before the students used the unit, two water samples from the water syringe and water turbine was collected. The samples were transferred to the laboratory. After 48 h at 37°C, the microbial colonies were counted. The number of these colonies was evaluated using colony forming unit CFU. Data were analyzed with Mann — Whitney U test and SPSS 13.5 statistical program. The statistical significance was defined at P ≤ 0.05. Results: All 35 units were contaminated before chlorhexidine use; no contamination was detected after adding chlorhexidine to the waterlines of the units. After week 1, 28 of the 30 treated dental unit waterlines (DUWLs) had values of CFU/mL less than 200. Conclusion: The present study showed that the use of chlorhexidine could reduce microbial counts in dental unit waterlines. PMID:25097645

  14. Effect of 0.2% chlorhexidine on microbial and fungal contamination of dental unit waterlines.

    PubMed

    Agahi, Raha Habib; Hashemipour, Maryam Alsadat; Kalantari, Mahsa; Ayatollah-Mosavi, Amin; Aghassi, Hossein; Nassab, Amir Hossein Gandjalikhan

    2014-05-01

    It is known that dental unit waterline can be a source of infection. The aim of this study was to evaluate the efficacy of a mouthwash, chlorhexidine, in controlling microbial and fungal contamination of dental unit waterlines. In the present experimental study, the water in high-speed handpieces and air/water syringes of 35 dental units in a dental school was investigated microbiologically. Five of the units and one tap water served as controls; 100-200-mL water samples were collected aseptically in sterile containers in the morning after a 2-min purge. Water reservoir bottles were emptied and 50 mL of 0.2% chlorhexidine mouthwash was introduced into the tank. Then the water syringe was used to flush the waterline until the pink-colored chlorhexidine was observed to flow from the water syringe. Before the next day's session and before the students used the unit, two water samples from the water syringe and water turbine was collected. The samples were transferred to the laboratory. After 48 h at 37°C, the microbial colonies were counted. The number of these colonies was evaluated using colony forming unit CFU. Data were analyzed with Mann - Whitney U test and SPSS 13.5 statistical program. The statistical significance was defined at P ≤ 0.05. All 35 units were contaminated before chlorhexidine use; no contamination was detected after adding chlorhexidine to the waterlines of the units. After week 1, 28 of the 30 treated dental unit waterlines (DUWLs) had values of CFU/mL less than 200. The present study showed that the use of chlorhexidine could reduce microbial counts in dental unit waterlines.

  15. A research on snow distribution in mountainous area using airborne laser scanning

    NASA Astrophysics Data System (ADS)

    Nishihara, T.; Tanise, A.

    2015-12-01

    In snowy cold regions, the snowmelt water stored in dams in early spring meets the water demand for the summer season. Thus, snowmelt water serves as an important water resource. However, snowmelt water also can cause snowmelt floods. Therefore, it's necessary to estimate snow water equivalent in a dam basin as accurately as possible. For this reason, the dam operation offices in Hokkaido, Japan conduct snow surveys every March to estimate snow water equivalent in the dam basin. In estimating, we generally apply a relationship between elevation and snow water equivalent. But above the forest line, snow surveys are generally conducted along ridges due to the risk of avalanches or other hazards. As a result, snow water equivalent above the forest line is significantly underestimated. In this study, we conducted airborne laser scanning to measure snow depth in the high elevation area including above the forest line twice in the same target area (in 2012 and 2015) and analyzed the relationships of snow depth above the forest line and some indicators of terrain. Our target area was the Chubetsu dam basin. It's located in central Hokkaido, a high elevation area in a mountainous region. Hokkaido is a northernmost island of Japan. Therefore it's a cold and snowy region. The target range for airborne laser scanning was 10km2. About 60% of the target range was above the forest line. First, we analyzed the relationship between elevation and snow depth. Below the forest line, the snow depth increased linearly with elevation increase. On the other hand, above the forest line, the snow depth varied greatly. Second, we analyzed the relationship between overground-openness and snow depth above the forest line. Overground-openness is an indicator quantifying how far a target point is above or below the surrounding surface. As a result, a simple relationship was clarified. Snow depth decreased linearly as overground-openness increases. This means that areas with heavy snow cover are distributed in valleys and that of light cover are on ridges. Lastly we compared the result of 2012 and that of 2015. The same characteristic of snow depth, above mentioned, was found. However, regression coefficients of linear equations were different according to the weather conditions of each year.

  16. Impact of water quality change on corrosion scales in full and partially replaced lead service lines

    EPA Science Inventory

    BackgroundChanges in water qualities have been associated with an increase in lead release from full and partial lead service lines (LSLs), such as the cases of Washington D.C. or more recently of Flint (Mi). Water qualities affect the mineralogy of the scales. Furthermore, follo...

  17. Effect of disinfectant, water age, and pipe materials on bacterial and eukaryotic community structure in drinking water biofilm.

    PubMed

    Wang, Hong; Masters, Sheldon; Edwards, Marc A; Falkinham, Joseph O; Pruden, Amy

    2014-01-01

    Availability of safe, pathogen-free drinking water is vital to public health; however, it is impossible to deliver sterile drinking water to consumers. Recent microbiome research is bringing new understanding to the true extent and diversity of microbes that inhabit water distribution systems. The purpose of this study was to determine how water chemistry in main distribution lines shape the microbiome in drinking water biofilms and to explore potential associations between opportunistic pathogens and indigenous drinking water microbes. Effects of disinfectant (chloramines, chlorine), water age (2.3 days, 5.7 days), and pipe material (cement, iron, PVC) were compared in parallel triplicate simulated water distribution systems. Pyrosequencing was employed to characterize bacteria and terminal restriction fragment polymorphism was used to profile both bacteria and eukaryotes inhabiting pipe biofilms. Disinfectant and water age were both observed to be strong factors in shaping bacterial and eukaryotic community structures. Pipe material only influenced the bacterial community structure (ANOSIM test, P < 0.05). Interactive effects of disinfectant, pipe material, and water age on both bacteria and eukaryotes were noted. Disinfectant concentration had the strongest effect on bacteria, while dissolved oxygen appeared to be a major driver for eukaryotes (BEST test). Several correlations of similarity metrics among populations of bacteria, eukaryotes, and opportunistic pathogens, as well as one significant association between mycobacterial and proteobacterial operational taxonomic units, provides insight into means by which manipulating the microbiome may lead to new avenues for limiting the growth of opportunistic pathogens (e.g., Legionella) or other nuisance organisms (e.g., nitrifiers).

  18. Water absorption characteristic of interlocking compressed earth brick units

    NASA Astrophysics Data System (ADS)

    Bakar, B. H. Abu; Saari, S.; Surip, N. A.

    2017-10-01

    This study aims to investigate the water absorption characteristic of interlocking compressed earth brick (ICEB) units. Apart from compressive strength, water absorption is an important property in masonry. This property can affect the quality of the brick itself and the bond strength between the brick and mortar in masonry structures and can result in reducing its strength properties. The units were tested for 24 h water absorption and 5 h boiling water absorption. A total of 170 ICEB units from four ICEB types underwent both tests. For the 24 h water absorption, the ICEB units were dried in the oven for 24 h and then cooled before being weighed. Thereafter, each brick was immersed in water for 24 h and weighed. The same specimens used for the 24 h water absorption test were re-used for the 5 h boiling water absorption test. After completing the 24 h water absorption test, the brick was boiled for 5-hours and weighed. The highest water absorption for the ICEBs in the 24-hour water absorption and 5 h boiling water absorption tests are 15.09% and 17.18%, respectively. The half brick has the highest water absorption (15.87%), whereas the beam brick has the lowest (13.20%). The water absorption of an ICEB unit is higher than that of normal bricks, although the water absorption of the former remains below the maximum rate of the brick water absorption (21%).

  19. The separation of the Hartland Formation and Ravenswood Granodiorite from the Fordham Gneiss at Cameron's Line in the New York City area

    USGS Publications Warehouse

    Baskerville, C.A.; Mose, D.G.

    1989-01-01

    Recent study of the rocks in City Water Tunnel Number 3 between Roosevelt Island and beneath 34th Street and the 63rd Street subway-rail tunnels at 41st Avenue in Long Island City, as well as study of drill core from other sites in western Queens, establishes that this area of New York City is underlain by the Ravenswood Granodiorite and the Hartland Formation. The Fordham Gneiss does not appear east of the East River at these sites. Cameron's Line can be traced down the east side of the East River, as learned from observations in the tunnels, separating the Middle Proterozoic Fordham Gneiss to the west from the Cambrian and Ordovician Hartland Formation and related Ravenswood Granodiorite to the east. The older, adequately defined, Ravenswood Granodiorite, Hartland Formation, and the Fordham Gneiss, are the rock units that make up the poorly defined Brooklyn gneiss or Brooklyn Injection Gneiss and thus appropriately should supercede these later classifications. -from Authors

  20. The Ice Line in Pre-Solar Protoplanetary Disks

    NASA Technical Reports Server (NTRS)

    Davis, Sanford S.

    2012-01-01

    Protoplanetary disks contain abundant quantities of water molecules in both gas and solid phases. The distribution of these two phases in an evolving protoplanetary disk will have important consequences regarding water sequestration in planetary embryos. The boundary between gaseous and solid water is the "ice line" or "snow line" A simplified model that captures the complicated two-branched structure of the ice line is developed and compared with recent investigations. The effect of an evolving Sun is also included for the first time. This latter parameter could have important consequences regarding the thermodynamic state and the surface reaction environment for the time-dependent chemical reactions occurring during the 1- to 10-million-year lifetime of the pre-solar disk.

  1. IR spectroscopy of water vapor confined in nanoporous silica aerogel.

    PubMed

    Ponomarev, Yu N; Petrova, T M; Solodov, A M; Solodov, A A

    2010-12-06

    The absorption spectrum of the water vapor, confined in the nanoporous silica aerogel, was measured within 5000-5600 cm(-1) with the IFS 125 HR Fourier spectrometer. It has been shown, that tight confinement of the molecules by the nanoporous size leads to the strong lines broadening and shift. For water vapor lines, the HWHM of confined molecules are on the average 23 times larger than those for free molecules. The shift values are in the range from -0.03 cm(-1) to 0.09 cm(-1). Some spectral lines have negative shift. The data on the half-widths and center shifts for some strongest H(2)O lines have been presented.

  2. WATER MASERS IN THE ANDROMEDA GALAXY. I. A SURVEY FOR WATER MASERS, AMMONIA, AND HYDROGEN RECOMBINATION LINES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Darling, Jeremy; Gerard, Benjamin; Amiri, Nikta

    We report the results of a Green Bank Telescope survey for water masers, ammonia (1, 1) and (2, 2), and the H66 α recombination line toward 506 luminous compact 24 μ m emitting regions in the Andromeda Galaxy (M31). We include the 206 sources observed in the Darling water maser survey for completeness. The survey was sensitive enough to detect any maser useful for ∼10 μ as yr{sup 1} astrometry. No new water masers, ammonia lines, or H66 α recombination lines were detected individually or in spectral stacks reaching rms noise levels of ∼3 mJy and ∼0.2 mJy, respectively, inmore » 3.1–3.3 km s{sup 1} channels. The lack of detections in individual spectra and in the spectral stacks is consistent with Galactic extrapolations. Contrary to previous assertions, there do not seem to be any additional bright water masers to be found in M31. The strong variability of water masers may enable new maser detections in the future, but variability may also limit the astrometric utility of known (or future) masers because flaring masers must also fade.« less

  3. Aerosol counterflow two-jets unit for continuous measurement of the soluble fraction of atmospheric aerosols.

    PubMed

    Mikuska, Pavel; Vecera, Zbynek

    2005-09-01

    A new type of aerosol collector employing a liquid at laboratory temperature for continuous sampling of atmospheric particles is described. The collector operates on the principle of a Venturi scrubber. Sampled air flows at high linear velocity through two Venturi nozzles "atomizing" the liquid to form two jets of a polydisperse aerosol of fine droplets situated against each other. Counterflow jets of droplets collide, and within this process, the aerosol particles are captured into dispersed liquid. Under optimum conditions (air flow rate of 5 L/min and water flow rate of 2 mL/min), aerosol particles down to 0.3 microm in diameter are quantitatively collected in the collector into deionized water while the collection efficiency of smaller particles decreases. There is very little loss of fine aerosol within the aerosol counterflow two-jets unit (ACTJU). Coupling of the aerosol collector with an annular diffusion denuder located upstream of the collector ensures an artifact-free sampling of atmospheric aerosols. Operation of the ACTJU in combination with on-line detection devices allows in situ automated analysis of water-soluble aerosol species (e.g., NO2-, NO3-)with high time resolution (as high as 1 s). Under the optimum conditions, the limit of detection for particulate nitrite and nitrate is 28 and 77 ng/m(3), respectively. The instrument is sufficiently rugged for its application at routine monitoring of aerosol composition in the real time.

  4. Development of a microwave clothes dryer. Interim report II

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, R.D.; Gerling, J.E.

    The objective of the project is to investigate the microwave drying of clothes and to produce a database for use by interested parties, including appliance manufacturers, in designing and developing microwave clothes dryers. This is an interim report covering 1992 activities. Performance of a research model of a microwave dryer was compared to that of a conventional (top-of-the-line) electric dryer. Drying time was reduced by 58%; superior fabric care was demonstrated on fine fabrics because of the low drying temperatures; and efficiency was increased 18%. Microwaves penetrate the clothes and heat the water molecules directly while conventional heat energy mustmore » be conducted through the clothes to heat the water. A flow of heated air conducts the water vapor away from the clothes. Conventional metal buttons and zippers do not heat greatly in the 2,450 MHz microwave field but bobby pins, bread ties and nails heat enough to damage clothes. That heating has been eliminated by switching to the 915-MHz microwave frequency. Metallized threads may still constitute a heating problem. Based upon results from tests of the research model, a prototype has been designed and three units have been constructed. One unit is retained for laboratory testing while the other two will be shipped to two major appliance manufacturers for evaluations in their laboratories. Consumer panels generally liked the high speed, fabric care and improved efficiency of the microwave dryer but were concerned about the higher first cost.« less

  5. The Rome Laboratory Reliability Engineer’s Toolkit

    DTIC Science & Technology

    1993-04-01

    34Testability Programs for Electronic Systems and Equipment" DODD 5000.1 "Defense Acquistion " DODI 5000.2 "Defense Acquisition Management Policies and...these paths have an equivalent failure rate of zero so that only the remaining serial elements need to be translated. 5. The requirement process...X6) X A2+B2+XAXB One standby off-line unit with n active on- line units required for success. Off-line spare assumed to have a failure rate of zero

  6. 78 FR 42758 - Extension of Comment Period for Request of the United States Patent and Trademark Office for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-17

    ... other voluntary initiatives to reduce intellectual property infringement that occurs on-line--such as... other voluntary initiatives to reduce intellectual property infringement that occurs on-line--such as... Commerce for Intellectual Property and Acting Director of the United States Patent and Trademark Office...

  7. 76 FR 20954 - Certain Lined Paper Products From India: Amended Final Determination of Sales at Less Than Fair...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-14

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-533-843] Certain Lined Paper Products..., International Trade Administration, Department of Commerce. SUMMARY: On December 13, 2010, the United States Court of Appeals for the Federal Circuit (``CAFC'') affirmed the United States Court of International...

  8. 1:100,000-scale Counties of the United States

    USGS Publications Warehouse

    ,

    1993-01-01

    This is a coverage of the county boundaries of the conterminous United States (AK, HI and Puerto Rico are available separately). The lines were extracted from U.S. Census TIGER/line files using an AML program (see 4.), written by Doug Nebert and Mark Negri, running on two Data General 6220 servers.

  9. 78 FR 53493 - Presidential Permits: NOVA Chemicals Inc. Line 20 Facilities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-29

    ... natural gas liquids from the United States to Ontario, Canada. The Line 20 facilities were constructed in 1986 and operated most recently by another entity for the transport of natural gas pursuant to a..., for the export of natural gas liquids from the United States to Canada. The term ``facilities'' as...

  10. Patterns of Second-Line Uterotonic Use in a Large Sample of Hospitalizations for Childbirth in the United States: 2007 - 2011

    PubMed Central

    Bateman, Brian T.; Tsen, Lawrence C.; Liu, Jun; Butwick, Alexander J.; Huybrechts, Krista F.

    2015-01-01

    Introduction The incidence of postpartum hemorrhage due to uterine atony has increased significantly in the United States during the past decade. For patients with refractory uterine atony after oxytocin administration, second-line uterotonics including methylergonovine maleate, carboprost, and misoprostol are recommended. In this study we describe hospital-level patterns of second-line uterotonic use in a large, nationwide sample of admissions for childbirth in the United States. Methods The Premier Research Database was used to define a cohort of 2,180,916 patients hospitalized for delivery at 1 of 367 hospitals from 2007 to 2011. Mixed-effects logistic regression models were used to estimate the hospital-specific frequency of second-line uterotonic use adjusting for measured patient-level and hospital-level characteristics that might be risk factors for uterine atony. Results The median hospital-level frequency of second-line uterotonic use was 7.1% (interquartile range 5.2% to 10.8%). In the fully adjusted model, the mean (SE) predicted probability of second-line uterotonic use was 7.02% (0.26%), with 95% of the hospitals having a predicted (SE) probability between 1.69% (0.12%) and 24.96% (1.28%). Conclusions We observed wide interhospital variation in the use of second-line uterotonics that was not explained by patient-level or hospital-level characteristics. Studies aimed at defining the optimal pharmacologic strategies for the management of uterine atony are needed, particularly in light of the increasing incidence of atonic postpartum hemorrhage in the United States and other developed countries. PMID:25166464

  11. Cost-effectiveness of a quality improvement programme to reduce central line-associated bloodstream infections in intensive care units in the USA.

    PubMed

    Herzer, Kurt R; Niessen, Louis; Constenla, Dagna O; Ward, William J; Pronovost, Peter J

    2014-09-25

    To assess the cost-effectiveness of a multifaceted quality improvement programme focused on reducing central line-associated bloodstream infections in intensive care units. Cost-effectiveness analysis using a decision tree model to compare programme to non-programme intensive care units. USA. Adult patients in the intensive care unit. Economic costs of the programme and of central line-associated bloodstream infections were estimated from the perspective of the hospital and presented in 2013 US dollars. Central line-associated bloodstream infections prevented, deaths averted due to central line-associated bloodstream infections prevented, and incremental cost-effectiveness ratios. Probabilistic sensitivity analysis was performed. Compared with current practice, the programme is strongly dominant and reduces bloodstream infections and deaths at no additional cost. The probabilistic sensitivity analysis showed that there was an almost 80% probability that the programme reduces bloodstream infections and the infections' economic costs to hospitals. The opportunity cost of a bloodstream infection to a hospital was the most important model parameter in these analyses. This multifaceted quality improvement programme, as it is currently implemented by hospitals on an increasingly large scale in the USA, likely reduces the economic costs of central line-associated bloodstream infections for US hospitals. Awareness among hospitals about the programme's benefits should enhance implementation. The programme's implementation has the potential to substantially reduce morbidity, mortality and economic costs associated with central line-associated bloodstream infections. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  12. Elongated phytoglycogen chain length in transgenic rice endosperm expressing active starch synthase IIa affects the altered solubility and crystallinity of the storage α-glucan

    PubMed Central

    Fujita, Naoko; Toyosawa, Yoshiko; Utsumi, Yoshinori

    2012-01-01

    The relationship between the solubility, crystallinity, and length of the unit chains of plant storage α-glucan was investigated by manipulating the chain length of α-glucans accumulated in a rice mutant. Transgenic lines were produced by introducing a cDNA for starch synthase IIa (SSIIa) from an indica cultivar (SSIIa I, coding for active SSIIa) into an isoamylase1 (ISA1)-deficient mutant (isa1) that was derived from a japonica cultivar (bearing inactive SSIIa proteins). The water-soluble fraction accounted for >95% of the total α-glucan in the isa1 mutant, whereas it was only 35–70% in the transgenic SSIIa I /isa1 lines. Thus, the α-glucans from the SSIIa I /isa1 lines were fractionated into soluble and insoluble fractions prior to the following characterizations. X-ray diffraction analysis revealed a weak B-type crystallinity for the α-glucans of the insoluble fraction, while no crystallinity was confirmed for α-glucans in isa1. Concerning the degree of polymerization (DP) ≤30, the chain lengths of these α-glucans differed significantly in the order of SSIIa I /isa1 insoluble > SSIIa I /isa1 soluble > α-glucans in isa1. The amount of long chains with DP ≥33 was higher in the insoluble fraction α-glucans than in the other two α-glucans. No difference was observed in the chain length distributions of the β-amylase limit dextrins among these α-glucans. These results suggest that in the SSIIa I /isa1 transgenic lines, the unit chains of α-glucans were elongated by SSIIaI, whereas the expression of SSIIaI did not affect the branch positions. Thus, the observed insolubility and crystallinity of the insoluble fraction can be attributed to the elongated length of the outer chains due to SSIIaI. PMID:23048127

  13. Aiming for zero: decreasing central line associated bacteraemia in the intensive care unit.

    PubMed

    Seddon, Mary E; Hocking, Catherine J; Mead, Pat; Simpson, Catherine

    2011-07-29

    To eliminate Central Line Associated Bacteraemia (CLAB) in the Critical Care Complex (CCC)-Intensive Care Unit (ICU) and High Dependency Unit (HDU)-Middlemore Hospital. Multifaceted quality improvement programme that included: engagement with ICU leadership and education of ICU staff; the introduction of a CLAB prevention bundle of care through standardised checklists for central line insertion (December 2008) and line maintenance (July 2009); the development of a central line pack; and rapid, visual feedback of results. Absolute numbers of CLAB in the CCC decreased from 14 in 2008, to 4 in 2009 and 1 in the first 6 months of 2010 (despite increase in bed census and a doubling of admissions). The CLAB rate per 1,000 line days decreased from 6.6 to 0.9. The days between CLAB increased from a median of 30 to >100 days, with zero CLAB for 5 of the last 6 months. Mortality for patients with CLAB was 37%, compared with mortality of 13% for all other ICU patients. The conservative cost savings were $200,000 in 2009 and $260,000 in 2010. Using an evidenced-based quality improvement approach, it is possible to significantly decrease Central Line Associated Bacteraemia in the Critical Care Complex. In doing so patient morbidity and mortality are reduced and money is saved for other healthcare needs.

  14. Disinfection of contaminated water by using solar irradiation.

    PubMed

    Caslake, Laurie F; Connolly, Daniel J; Menon, Vilas; Duncanson, Catriona M; Rojas, Ricardo; Tavakoli, Javad

    2004-02-01

    Contaminated water causes an estimated 6 to 60 billion cases of gastrointestinal illness annually. The majority of these cases occur in rural areas of developing nations where the water supply remains polluted and adequate sanitation is unavailable. A portable, low-cost, and low-maintenance solar unit to disinfect unpotable water has been designed and tested. The solar disinfection unit was tested with both river water and partially processed water from two wastewater treatment plants. In less than 30 min in midday sunlight, the unit eradicated more than 4 log10 U (99.99%) of bacteria contained in highly contaminated water samples. The solar disinfection unit has been field tested by Centro Panamericano de Ingenieria Sanitaria y Ciencias del Ambiente in Lima, Peru. At moderate light intensity, the solar disinfection unit was capable of reducing the bacterial load in a controlled contaminated water sample by 4 log10 U and disinfected approximately 1 liter of water in 30 min.

  15. Hydrogeologic framework and estimates of ground-water volumes in Tertiary and upper Cretaceous hydrogeologic units in the Powder River basin, Wyoming

    USGS Publications Warehouse

    Hinaman, Kurt

    2005-01-01

    The Powder River Basin in Wyoming and Montana is an important source of energy resources for the United States. Coalbed methane gas is contained in Tertiary and upper Cretaceous hydrogeologic units in the Powder River Basin. This gas is released when water pressure in coalbeds is lowered, usually by pumping ground water. Issues related to disposal and uses of by-product water from coalbed methane production have developed, in part, due to uncertainties in hydrologic properties. One hydrologic property of primary interest is the amount of water contained in Tertiary and upper Cretaceous hydrogeologic units in the Powder River Basin. The U.S. Geological Survey, in cooperation with the Bureau of Land Management, conducted a study to describe the hydrogeologic framework and to estimate ground-water volumes in different facies of Tertiary and upper Cretaceous hydrogeologic units in the Powder River Basin in Wyoming. A geographic information system was used to compile and utilize hydrogeologic maps, to describe the hydrogeologic framework, and to estimate the volume of ground water in Tertiary and upper Cretaceous hydrogeologic units in the Powder River structural basin in Wyoming. Maps of the altitudes of potentiometric surfaces, altitudes of the tops and bottoms of hydrogeologic units, thicknesses of hydrogeologic units, percent sand of hydrogeologic units, and outcrop boundaries for the following hydrogeologic units were used: Tongue River-Wasatch aquifer, Lebo confining unit, Tullock aquifer, Upper Hell Creek confining unit, and the Fox Hills-Lower Hell Creek aquifer. Literature porosity values of 30 percent for sand and 35 percent for non-sand facies were used to calculate the volume of total ground water in each hydrogeologic unit. Literature specific yield values of 26 percent for sand and 10 percent for non-sand facies, and literature specific storage values of 0.0001 ft-1 (1/foot) for sand facies and 0.00001 ft-1 for non-sand facies, were used to calculate a second volume of ground water for each hydrogeologic unit. Significant figure considerations limited estimates of ground-water volumes to two significant digits. A total ground-water volume of 2.0x1014 ft3 (cubic feet) was calculated using porosity values, and a total ground-water volume of 3.6x1013 ft3 was calculated using specific yield and specific storage values. These results are consistent with retention properties, which would have some of the total water being retained in the sediments. Sensitivity analysis shows that the estimates of ground-water volume are most sensitive to porosity. The estimates also are sensitive to confined thickness and saturated thickness. Better spatial information for hydrogeologic units could help refine the ground-water volume estimates.

  16. Prevention of microbial contamination of the dental unit caused by suction into the turbine drive air lines.

    PubMed

    Ojajärvi, J

    1996-01-01

    To determine whether a specially designed antisuction device can prevent the bacterial contamination of the drive air lines of the dental turbine that is caused by suction when the turbine is stopped. A dental unit with and without the antisuction device and three different types of sterilized handpieces were used in the tests. Each turbine was operated in air, then submerged into a bacterial suspension of E. coli and enterococci for 3 seconds, removed, and stopped. This procedure was repeated 10 times. Possible bacterial contamination of the drive air lines was examined by submersing the head of a sterilized handpiece with the turbine running into a nutrient broth for 30 seconds. The broth was incubated at 35 degrees C up to 2 days. After use of the conventional dental unit, bacterial growth of drive air lines was found in 10 of 150 broth samples. After the installation of the antisuction device no bacterial growth was found in any of the 138 samples. The difference in the contamination frequencies is statistically significant (p = 0.011, Fisher's two-sided exact test). The drive air lines of the turbine in the dental unit may become contaminated despite the sterilization of handpieces. The antisuction device installed into the dental unit was found to prevent the contamination. With the exception of possibly immunocompromised patients, the transmission of microbes by exhaust air may be too small to cause infections. However, transmission of oral material between patients should be prevented in dental practice.

  17. Hydrologic Unit Map -- 1978, state of South Dakota

    USGS Publications Warehouse

    ,

    1978-01-01

    This map and accompanying table show Hydrologic Unites that are basically hydrographic in nature. The Cataloging Unites shown supplant the Cataloging Units previously depicted n the 1974 State Hydrologic Unit Map. The boundaries as shown have been adapted from the 1974 State Hydrologic Unit Map, "The Catalog of Information on Water Data" (1972), "Water Resources Regions and Subregions for the National Assessment of Water and Related Land Resources" by the U.S. Water Resources Council (1970), "River Basin of the United States" by the U.S. Soil Conservation Service (1963, 1970), "River Basin Maps Showing Hydrologic Stations" by the Inter-Agency Committee on Water Resources, Subcommittee on Hydrology (1961), and State planning maps. The Political Subdivision has been adopted from "Counties and County Equivalents of the States if the United States" presented in Federal Information Processing Standards Publication 6-2, issued by the National Bureau of Standards (1973) in which each county or county equivalent is identified by a 2-character State code and a 3-character county code. The Regions, Subregions and Accounting Units are aggregates of the Cataloging Unites. The Regions and Sub regions are currently (1978) used by the U.S> Water Resources Council for comprehensive planning, including the National Assessment, and as a standard geographical framework for more detailed water and related land-resources planning. The Accounting Units are those currently (1978) in use by the U.S. Geological Survey for managing the National Water Data Network. This map was revised to include a boundary realinement between Cataloging Units 10140103 and 10160009.

  18. Full-scale phosphorus recovery from digested waste water sludge in Belgium - part I: technical achievements and challenges.

    PubMed

    Marchi, A; Geerts, S; Weemaes, M; Schiettecatte, W; Wim, S; Vanhoof, C; Christine, V

    2015-01-01

    To date, phosphorus recovery as struvite in wastewater treatment plants has been mainly implemented on water phases resulting from dewatering processes of the sludge line. However, it is possible to recover struvite directly from sludge phases. Besides minimising the return loads of phosphorus from the sludge line to the water line, placing such a process within the sludge line is claimed to offer advantages such as a higher recovery potential, enhanced dewaterability of the treated sludge, and reduced speed of scaling in pipes and dewatering devices. In the wastewater treatment plant at Leuven (Belgium), a full-scale struvite recovery process from digested sludge has been tested for 1 year. Several monitoring campaigns and experiments provided indications of the efficiency of the process for recovery. The load of phosphorus from the sludge line returning to the water line as centrate accounted for 15% of the P-load of the plant in the reference situation. Data indicated that the process divides this phosphorus load by two. An improved dewaterability of 1.5% of dry solids content was achieved, provided a proper tuning of the installation. Quality analyses showed that the formed struvite was quite pure.

  19. Automatic, sterile, and apyrogenic delivery of PET radiotracers from the cyclotron to the patient

    NASA Astrophysics Data System (ADS)

    Votaw, J. R.; Cashion, D. B.; Clanton, J. A.

    1991-05-01

    An automatic delivery remote injection system has been developed to administer either 13N-labelled ammonia, or 15O-labelled water or 18F-labelled FDG to patients. Automation increases the throughout and efficiency of the PET center, and remote dose administration ensures patient safety and reduces the radiation exposure to the technologist supervising the radiopharmaceutical injection. The remote dose administration apparatus utilizes a syringe pump to transfer liquid activity and a solenoid three-way valve to switch between lines connected to a patient and a receiving vial. To ensure apyrogenicity and sterility of the injected product, the entire system is washed with sterile water before it is used. Since the tracer is delivered in an ~ 8 ml bolus of water, the next delivery through the system is considered safe for injection if pyrogens are not detected at a threshold of 3 endotoxin units per ml (EU/ml) in the wash. Time delayed tests shows that the system may be left unused for up to 6 h before the wash must be repeated.

  20. Low-temperature incubation using a water supply

    USGS Publications Warehouse

    Wolf, K.; Quimby, M.C.

    1967-01-01

    Cell and tissue culture has been concerned primarily with homiothermic vertebrate cells which require incubation at about 37 C, and there is a great variety of incubators designed to maintain temperatures which are usually above ambient. The culture of poikilothermic vertebrate cells--and invertebrate, plant, and some microbial cells--can often be carried out at ambient temperatures, but for some work cooler conditions must be provided. Variety among the so-called low-temperature incubators is somewhat restricted; there are no small units, and all require a power source to maintain temperatures below ambient. We have used a gravity-fed water supply for 5 years to provide trouble-free, constant, low-temperature incubation of stock cultures of fish and amphibian cells. Though it is but a small part of our low-temperature incubator capacity, it has no power requirements and it provides maximal protection against temperature rises which could be lethal to some of the cell lines. Though the system has limitations, there is a considerable likelihood that the domestic water supply in other laboratories can also be used to provide low-temperature incubation.

  1. Geologic aspects of the surficial aquifer in the upper East Coast planning area, Southeast Florida

    USGS Publications Warehouse

    Miller, Wesley L.

    1980-01-01

    The Upper East Coast Planning Area, as designated by the South Florida Water Management District, consists of St. Lucie County, Martin County, and eastern Okeechobee County. The surficial aquifer is the main source of freshwater for agricultural and urban uses in the area. The geologic framework of the aquifer is displayed by contour mapping and lithologic cross sections to provide water managers with a better understanding of the natural restraints that may be imposed on future development. The surficial aquifer is primarily sand, limestone, shell, silt, and clay deposited during the Pleistocene and Pliocene Epochs. The aquifer is unconfined and under water-table conditions in most of the area, but locally, artesian conditions exits where discontinuous clay layers act as confining units. Impermeable and semipermeable clays and marls of the Tamiami (lower Pliocene) and Hawthorn Formations (Miocene) unconformably underlie the surficial aquifer and form its base. Contour lines showing the altitude of the base of the aquifer indicate extensive erosion of the Miocene sediments prior to deposition of the aquifer materials. (USGS)

  2. An ultra-sensitive method for the analysis of perfluorinated alkyl acids in drinking water using a column switching high-performance liquid chromatography tandem mass spectrometry.

    PubMed

    Dasu, Kavitha; Nakayama, Shoji F; Yoshikane, Mitsuha; Mills, Marc A; Wright, J Michael; Ehrlich, Shelley

    2017-04-21

    In epidemiological research, it has become increasingly important to assess subjects' exposure to different classes of chemicals in multiple environmental media. It is a common practice to aliquot limited volumes of samples into smaller quantities for specific trace level chemical analyses. A novel method was developed for the determination of 14 perfluorinated alkyl acids (PFAAs) in small volumes (10mL) of drinking water using off-line solid phase extraction (SPE) pre-treatment followed by on-line pre-concentration on a WAX column before analysis on column-switching high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS). In general, large volumes (100-1000mL) have been used for the analysis of PFAAs in drinking water. The current method requires approximately 10mL of drinking water concentrated by using an SPE cartridge and eluted with methanol. A large volume injection of the extract was introduced on to a column-switching HPLC-MS/MS using a mix-mode SPE column for the trace level analysis of PFAAs in water. The recoveries for most of the analytes in the fortified laboratory blanks ranged from 73±14% to 128±5%. The lowest concentration minimum reporting levels (LCMRL) for the 14 PFAAs ranged from 0.59 to 3.4ng/L. The optimized method was applied to a pilot-scale analysis of a subset of drinking water samples from an epidemiological study. These samples were collected directly from the taps in the households of Ohio and Northern Kentucky, United States and the sources of drinking water samples are both surface water and ground water, and supplied by different water distribution facilities. Only five PFAAs, perfluoro-1-butanesulfonic acid (PFBS), perfluoro-1- -hexanesulfonic acid (PFHxS), perfluoro-1-octanesulfonic acid (PFOS), perfluoro-n-heptanoic acid (PFHpA) and perfluoro-n-octanoic acid (PFOA) are detected above the LCMRL values. The median concentrations of these five PFAAs detected in the samples was ≤4.1ng/L with PFOS at 7.6ng/L and PFOA at 10ng/L. Concentrations of perfluoro-1-decanesulfonic acid, PFDS and other perfluoroalkyl carboxylic acids were below the LCMRL values. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Studying Phobos subsurface structure elementary composition by neutron and gamma-rays spectrometers "NS HEND" from "Phobos-Grunt" mission.

    NASA Astrophysics Data System (ADS)

    Kozyrev, S. Alexander; Litvak, Maxim; Malakhov, Alexey; Mokrousov, Maxim; Mitrofanov, Igor; Sanin, Anton; Schulz, Rita; Shvetsov, Valery; Rogozhin, Alexander; Timoshenko, Genagy; Tretyakov, Vladislav; Vostrukhin, Andrey

    The Neutron Spectrometer HEND (NS HEND) has been proposed for studying elemental com-position of Phobos (the Mars's moon) regolith by "Phobos-Grunt" mission. NS HEND have been selected by the Federal Space Agency of Russia for the Lander of the "Phobos-Grunt" mission scheduled for launch in 2011. The shallow subsurface of Phobos might be studied by observations of induced nuclear gamma-ray lines and neutron emission. Secondary gamma-rays and neutrons are produced by energetic Galactic Cosmic Rays within 1-2 meter layer of subsur-face. The knowledge of the spectral density of neutrons in addition to measurements of nuclear gamma lines allows to deconvolve concentrations of soil-constituting elements. That is why nuclear instruments include both the segment for detection of gamma ray lines and segment of neutron spectrometer for the measurement of the neutron leakage spectra. Moreover, mea-surements of neutrons at 2.2 MeV line will also allow to study the content of hydrogen within subsurface layer about 1 meter deep. This instrument, will be able to provide observational data for composition of Phobos regolith and content of natural radioactive elements K, U and Th, and also for content of hydrogen or water ice in the Phobos subsurface. At present, the flight units of NS HEND instrument is manufactured, tested and current go through physical calibration.

  4. 77 FR 57084 - National Pollutant Discharge Elimination System (NPDES): Draft General Permit for Point Source...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-17

    ..., including to conveyances to Waters of the United States, including interstate waters that flow across or... Treatment Systems to Waters of the United States, Including to Conveyances to Waters of the United States, Including Interstate Waters That Flow Across or Form Part of the Boundary of Illinois and in All Areas of...

  5. Monterrey, Mexico as seen from STS-60

    NASA Image and Video Library

    1994-02-09

    STS060-83-041 (3-11 Feb 1994) --- The large city of Monterrey, in northeastern Mexico, was founded at the edge between the Sierra Madre Oriental and the Rio Grande Embayment portion of the Gulf Coastal Plain. This location is analogous to the Fall Line along the United States eastern seaboard, but instead of lying along a stream at the head of navigation, Monterrey lies at the boundary between a well-watered mountain range and a semi-arid plain where irrigation is often necessary for successful agriculture. The mountains themselves are formed from folded limestone and shale beds; to the south of the city, beds are crumpled into tight folds. Around and north of the city, more open folds gradually give way to nearly flat-lying beds of the coastal plain. Because of the water and other resources such as shale and limestone to quarry and burn for cement, Monterrey early became a thriving industrial center. It is now one of Mexico's largest cities with a population of approximately 5 million. According to NASA geologists, the STS-60 photography of this area is the best that has been acquired during the past 32 years of space photography by the United States. Monterrey remains an area of high interest for future photography in order to assess the impact of urbanization in this area.

  6. Lidar Measurements of Wind, Moisture, and Boundary Layer Evolution in a Dry Line during 1HOP 2002

    NASA Technical Reports Server (NTRS)

    Demoz, Belay; Evans, Keith; DiGirolamo, Paolo; Wang, Zhe-In; Whiteman, David; Schwemmer, Geary; Gentry, Bruce; Miller, David; Palm, Stephen

    2002-01-01

    Variability in the convective boundary layer moisture, wind and temperature fields and their importance in the forecasting and understanding of storms have been discussed in the literature. These . variations have been reported in relation to frontal zones, stationary boundaries and during horizontal convective rolls. While all three vary substantially in the convective boundary layer, moisture poses a particular challenge. Moisture or water vapor concentration (expressed as a mass mixing ratio, g/kg), is conserved in all meteorological processes except condensation and evaporation. The water vapor mixing ratio often remains distinct across an air-mass boundary even when the temperature difference is indistinct. These properties make it an ideal choice in visualizing and understanding many of the atmosphere's dynamic features. However, it also presents a unique measurement challenge because water vapor content can vary by more than three orders of magnitude in the troposphere. Characterization of the 3D-distribution of water vapor is also difficult as water vapor observations can suffer from large sampling errors and substantial variability both in the vertical and horizontal. This study presents ground-based measurements of wind, boundary layer structure and water vapor mixing ratio measurements observed by three co-located lidars. This presentation will focus on the evolution and variability of moisture and wind in the boundary layer during a dry line event that occurred on 22 May 2002. These data sets and analyses are unique in that they combine simultaneous measurements of wind, moisture and CBL structure to study the detailed thermal variability in and around clear air updrafts during a dryline event. It will quantify the variation caused by, in and around buoyant plumes and across a dryline. The data presented here were collected in the panhandle of Oklahoma as part of the International H2O Project (MOP-2002), a field experiment that took place over the Southern Great Plains (SGP) of the United States from 13 May to 30 June 2002. The chief goal of MOP-2002 is to improve characterization of the four-dimensional (4-D) distribution of water vapor and its application to improving the understanding and prediction of convection

  7. Selecting broiler chickens for ultimate pH of breast muscle: analysis of divergent selection experiment and phenotypic consequences on meat quality, growth, and body composition traits.

    PubMed

    Alnahhas, N; Berri, C; Boulay, M; Baéza, E; Jégo, Y; Baumard, Y; Chabault, M; Le Bihan-Duval, E

    2014-09-01

    Genetic parameters for ultimate pH of pectoralis major muscle (PM-pHu) and sartorius muscle (SART-pHu); color parameters L*, a*, b*; logarithm of drip loss (LogDL) of pectoralis major (PM) muscle; breast meat yield (BMY); thigh and drumstick yield (TY); abdominal fat percentage (AFP); and BW at 6 wk (BW6) were estimated in 2 lines of broiler chickens divergently selected for PM-pHu. Effects of selection on all the previous traits and on glycolytic potential, pectoralis major muscle pH at 15 min postmortem, curing-cooking yield (CCY), cooking loss (CL), and Warner-Bratzler shear force (WBSF) of the PM muscle were also analyzed after 5 generations. Strong genetic determinism of PM-pHu was observed, with estimated h(2) of 0.57 ± 0.02. There was a significant positive genetic correlation (rg) between PM-pHu and SART-pHu (0.54 ± 0.04), indicating that selection had a general rather than a specific effect on energy storage in skeletal muscles. The h(2) estimates of L*, a*, and b* parameters were 0.58 ± 0.02, 0.39 ± 0.02, and 0.48 ± 0.02, respectively. Heritability estimates for TY, BMY, and AFP were 0.39 ± 0.04, 0.52 ± 0.01, and 0.71 ± 0.02, respectively. Our results indicated different genetic control of LogDL and L* of the meat between the 2 lines; these traits had a strong rg with PM-pHu in the line selected for low ultimate pH (pHu) value (pHu-; -0.80 and -0.71, respectively), which was not observed in the line selected for high pHu value (pHu+; -0.04 and -0.29, respectively). A significant positive rg (0.21 ± 0.04) was observed between PM-pHu and BMY but not between PM-pHu and BW6, AFP, or TY. Significant phenotypic differences were observed after 5 generations of selection between the 2 lines. The mean differences (P < 0.001) in pHu between the 2 lines were 0.42 and 0.21 pH units in the breast and thigh muscle, respectively. Breast meat in the pHu+ line exhibited lower L* (-5 units; P < 0.001), a* (-0.22 units; P < 0.001), b* (-1.53 units; P < 0.001), and drip loss (-1.6 units; P < 0.001) than in the pHu- line. Breast meat of the pHu+ line was also characterized by greater CCY (+6.1 units; P < 0.001), lower CL (-1.66 units; P < 0.01), and lower WBSF after cooking (-5.1 units; P < 0.001) compared to the pHu- line. This study highlighted that selection based on pHu can be effective in improving the processing ability of breast meat and reducing the incidence of meat quality defects without affecting chicken growth performance.

  8. 48 CFR 252.204-7011 - Alternative Line Item Structure.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Unit Unit price Amount 0001 Computer, Desktop with CPU, Monitor, Keyboard and Mouse 20 EA Alternative... Unit Unit Price Amount 0001 Computer, Desktop with CPU, Keyboard and Mouse 20 EA 0002 Monitor 20 EA...

  9. 48 CFR 252.204-7011 - Alternative Line Item Structure.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Unit Unit price Amount 0001 Computer, Desktop with CPU, Monitor, Keyboard and Mouse 20 EA Alternative... Unit Unit Price Amount 0001 Computer, Desktop with CPU, Keyboard and Mouse 20 EA 0002 Monitor 20 EA...

  10. 48 CFR 252.204-7011 - Alternative Line Item Structure.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Unit Unit price Amount 0001 Computer, Desktop with CPU, Monitor, Keyboard and Mouse 20 EA Alternative... Unit Unit Price Amount 0001 Computer, Desktop with CPU, Keyboard and Mouse 20 EA 0002 Monitor 20 EA...

  11. 48 CFR 252.204-7011 - Alternative Line Item Structure.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Unit Unit price Amount 0001 Computer, Desktop with CPU, Monitor, Keyboard and Mouse 20 EA Alternative... Unit Unit Price Amount 0001 Computer, Desktop with CPU, Keyboard and Mouse 20 EA 0002 Monitor 20 EA...

  12. Early outbreak detection by linking health advice line calls to water distribution areas retrospectively demonstrated in a large waterborne outbreak of cryptosporidiosis in Sweden.

    PubMed

    Bjelkmar, Pär; Hansen, Anette; Schönning, Caroline; Bergström, Jakob; Löfdahl, Margareta; Lebbad, Marianne; Wallensten, Anders; Allestam, Görel; Stenmark, Stephan; Lindh, Johan

    2017-04-18

    In the winter and spring of 2011 a large outbreak of cryptosporidiosis occurred in Skellefteå municipality, Sweden. This study summarizes the outbreak investigation in terms of outbreak size, duration, clinical characteristics, possible source(s) and the potential for earlier detection using calls to a health advice line. The investigation included two epidemiological questionnaires and microbial analysis of samples from patients, water and other environmental sources. In addition, a retrospective study based on phone calls to a health advice line was performed by comparing patterns of phone calls between different water distribution areas. Our analyses showed that approximately 18,500 individuals were affected by a waterborne outbreak of cryptosporidiosis in Skellefteå in 2011. This makes it the second largest outbreak of cryptosporidiosis in Europe to date. Cryptosporidium hominis oocysts of subtype IbA10G2 were found in patient and sewage samples, but not in raw water or in drinking water, and the initial contamination source could not be determined. The outbreak went unnoticed to authorities for several months. The analysis of the calls to the health advice line provides strong indications early in the outbreak that it was linked to a particular water treatment plant. We conclude that an earlier detection of the outbreak by linking calls to a health advice line to water distribution areas could have limited the outbreak substantially.

  13. Basal Freeze-on: An Active Component of Hydrology from the Ice Divide to the Margin

    NASA Astrophysics Data System (ADS)

    Bell, R. E.; Tinto, K. J.; Abdi, A.; Creyts, T. T.; Wolovick, M.; Das, I.; Ferraccioli, F.; Csatho, B. M.

    2012-12-01

    Subglacial hydrology is considered a key control of ice sheet dynamics. Here we show that basal freeze-on is a process that can terminate basal hydrologic networks both in the interior of East Antarctica and at the margins of the Greenland Ice Sheet. Basal freeze-on modifies the ice thickness, ice structure, and ice rheology and therefore must be considered in developing accurate understanding of how hydrology interacts with ice dynamics. In East Antarctica, the freeze-on process follows well-defined hydrologic networks within Gamburtsev Mountain valleys. The steep mountain topography strongly controls the routing of the subglacial water. Ice surface slope drives the water up the mountain valleys and freeze-on occurs at the valley heads. Freeze-on ice is characterized by distinct basal radar reflectors that emerge from the hydrologic network. Evidence that these spatially coherent reflectors demark accreted ice is the upward deflection of the overlying internal layers accompanied by thickening of base of the ice sheet. Individual accretion bodies can be 25 km wide across flow, 100 km along flow with average thicknesses of ~500m although the maximum thickness is 1100m. Regional accumulation rates near the accretion sites average 4cm/yr with low ice velocity (1.5 m/yr). The volume of the ice enclosed by the accretion ice reflectors is 45-1064 km3. The accretion occurs beneath 2200-3000m thick ice and has been persistent for at least 50,000yr. Other basal reflectors in northern Greenland appear in radar from NASA's Icebridge mission and CRESIS. To identify freeze-on ice, we use specific criteria: reflectors must originate from the bed, must be spatially continuous from line to line and the meteoric stratigraphy is deflected upward. The absence of coincident gravity anomalies indicates these reflectors define distinct packages of ice rather than frozen sediment or off-nadir subglacial topography. In the Petermann Glacier Catchment, one of the largest in northern Greenland, we have identified 14 distinct basal ice packages over a wide region. The accumulation rate (~17 cm/yr) and ice velocity (~5-200m/yr) are higher than East Antarctica. These accretion bodies are 10-50 km wide, up to 940m thick and can be traced up to 140 km. The volume of the ice enclosed by the accretion ice reflector units is ~70-300 km3. We estimate that the freeze-on process in Petermann has been active for at least 6,000yr. Water has been mapped beneath much of the Greenland ice sheet and adjacent to the inland freeze-on site flat bright reflectors are interpreted as basal water. The onset of fast flow in Petermann Glacier is associated with the development of the thickest unit of freeze-on ice. Other areas of Greenland also have basal freeze-on ice. North of Jakobshavn Isbrae where the ice sheet is ~1000 m thick, evidence exists for a nearly 10 km wide, 200 m thick unit of basal ice in airborne radar. Located close to the site where basal freeze-on outcrops at the ice sheet margin at Pakitsoq, this unit may be the result of freeze-on of water draining from a supraglacial lake. Basal freeze-on is a critical component of subglacial hydrology. The evidence for large scale freeze-on East Antarctica and many areas of Greenland indicates widespread modification of the base of the ice sheet by basal hydrology.

  14. Laser absorption spectroscopy of water vapor confined in nanoporous alumina: wall collision line broadening and gas diffusion dynamics.

    PubMed

    Svensson, Tomas; Lewander, Märta; Svanberg, Sune

    2010-08-02

    We demonstrate high-resolution tunable diode laser absorption spectroscopy (TDLAS) of water vapor confined in nanoporous alumina. Strong multiple light scattering results in long photon pathlengths (1 m through a 6 mm sample). We report on strong line broadening due to frequent wall collisions (gas-surface interactions). For the water vapor line at 935.685 nm, the HWHM of confined molecules are about 4.3 GHz as compared to 2.9 GHz for free molecules (atmospheric pressure). Gas diffusion is also investigated, and in contrast to molecular oxygen (that moves rapidly in and out of the alumina), the exchange of water vapor is found very slow.

  15. WATER VAPOR IN THE PROTOPLANETARY DISK OF DG Tau

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Podio, L.; Dougados, C.; Thi, W.-F.

    2013-03-20

    Water is key in the evolution of protoplanetary disks and the formation of comets and icy/water planets. While high-excitation water lines originating in the hot inner disk have been detected in several T Tauri stars (TTSs), water vapor from the outer disk, where most water ice reservoirs are stored, was only reported in the nearby TTS TW Hya. We present spectrally resolved Herschel/HIFI observations of the young TTS DG Tau in the ortho- and para-water ground-state transitions at 557 and 1113 GHz. The lines show a narrow double-peaked profile, consistent with an origin in the outer disk, and are {approx}19-26more » times brighter than in TW Hya. In contrast, CO and [C II] lines are dominated by emission from the envelope/outflow, which makes H{sub 2}O lines a unique tracer of the disk of DG Tau. Disk modeling with the thermo-chemical code ProDiMo indicates that the strong UV field, due to the young age and strong accretion of DG Tau, irradiates a disk upper layer at 10-90 AU from the star, heating it up to temperatures of 600 K and producing the observed bright water lines. The models suggest a disk mass of 0.015-0.1 M{sub Sun }, consistent with the estimated minimum mass of the solar nebula before planet formation, and a water reservoir of {approx}10{sup 2}-10{sup 3} Earth oceans in vapor and {approx}100 times larger in the form of ice. Hence, this detection supports the scenario of ocean delivery on terrestrial planets by the impact of icy bodies forming in the outer disk.« less

  16. 75 FR 77662 - United States Section; Notice of Availability of a Final Environmental Assessment and Finding of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-13

    ... INTERNATIONAL BOUNDARY AND WATER COMMISSION, UNITED STATES AND MEXICO United States Section... States Section, International Boundary and Water Commission, United States and Mexico (USIBWC). ACTION... States Section, International Boundary and Water Commission; 4171 N. Mesa, C-100; El Paso, Texas 79902...

  17. Introduction to the General Campaign Analysis Model (GCAM). Version 3.3

    DTIC Science & Technology

    2009-09-01

    uncomment and change the label line to label = blackhawk; 14. For the unit to be displayed on the map, it needs a sprite. Uncomment the display style and...sprite lines and change them to display style = SPRITE; and sprite = blackhawk; this associates the unit with the Blackhawk sprite defined in the...infantry #UNIT id=102; label=squad; display style = SPRITE; sprite = infantry; sprite index0 = 0; sprite rotates = FALSE; x0 = 147.82; y0 = -19.26; #END

  18. Factors Associated with Type 2 Diabetes Mellitus Treatment Choice Across Four European Countries.

    PubMed

    Heintjes, Edith M; Overbeek, Jetty A; Hall, Gillian C; Prieto-Alhambra, Daniel; Lapi, Francesco; Hammar, Niklas; Bezemer, Irene D

    2017-11-01

    The aim of this analysis was to identify factors associated with the choice of type 2 diabetes mellitus (T2DM) therapy at the time of intensification of antidiabetic treatment across 4 European countries. Antidiabetic drug prescription/dispensing records and patients' characteristics were obtained from the electronic health care records of patients with T2DM from the Netherlands (NL), Italy, and Spain (ES) (all, 2007-2011); and the United Kingdom (UK; 2008-2012). Oral monotherapy was defined as first-line; oral dual therapy, as second-line; >2 oral treatments or oral combined with an injectable, as third-line; and injectables only, as fourth-line treatment. Treatment intensification was defined as the start of a higher line of treatment. Comedication, comorbidities, clinical parameters, and other factors associated with treatment choice were identified using multivariate relative risk estimation by Poisson regression with robust error variance. In the 5-year study period, 485,120 patients (79% of the treated T2DM population) underwent treatment intensification. Changes in treatment choice were clearly visible over the study period, such as a decline in the use of thiazolidinediones (NL, ES, UK) and increases in the use of dipeptidyl peptidase-4 inhibitors (DPP4i) (NL, ES, UK) and glucagon-like peptide-1 receptor agonists (UK). With first-line treatment, advanced age and renal comorbidity were associated with the use of sulfonylureas (SUs; all countries), whereas high body mass index (BMI) was inversely associated with SU use in the United Kingdom and Spain. With second-line treatment, advanced age was associated with metformin + SU use (all countries); and renal comorbidity with SU + DPP4i use in the United Kingdom and the Netherlands. High BMI was associated with metformin + thiazolidinedione (TZD) use in the United Kingdom and Spain, and with metformin + DPP4i in the United Kingdom. With third-line treatment, advanced age and renal comorbidity were associated with the use of SU + insulin (NL, ES, UK). Hemoglobin A 1c >8.5% was positively associated, and high BMI was inversely associated, with the use of any third-line combination containing insulin. Across treatment lines TZD and metformin were negatively associated with renal and cardiac morbidity. Second and third line treatment choices strongly depended on prior treatments. With fourth-line treatment, women were more likely to receive glucagon-like peptide-1 receptor agonists than were men in the United Kingdom and Spain. The results suggest that the main factors driving treatment choice at any stage of intensification were age, hemoglobin A 1c , BMI, renal and cardiac morbidity, and treatment history. These drivers were consistent with guidelines on, and contraindications of, specific medications. Differences between countries were generally consistent with, but not solely attributable to, differences in local guidelines and reimbursement policies. Copyright © 2017 Elsevier HS Journals, Inc. All rights reserved.

  19. Rapanos v. United States & Carabell v. United States

    EPA Pesticide Factsheets

    Documents associated with guidance for implementing the definition of waters of the United States under the Clean Water Act following the Rapanos v. United States, and Carabell v. United States Supreme Court decision.

  20. HYDROBS: a long-term autonomous mooring for passive acoustic monitoring

    NASA Astrophysics Data System (ADS)

    Hello, Y.; Royer, J. Y.; Yegikyan, M.

    2017-12-01

    Passive acoustics proves an effective way for monitoring the low-level seismic activity of the ocean floor and low-frequency sounds from the ocean (baleen whales, sea-state, icebergs). Networks of synchronized autonomous hydrophones have thus been commonly deployed in the world ocean to monitor large sections of mid-oceanic ridges. HYDROBS is an improved system that meet two requirements: an easy access to the data collected by the instruments together with long-term deployments - up to 4 consecutive years - reducing the need of large vessels capable of yearly mooring operations in open seas. The system has two components: a data logger, up-to-date but similar to previous systems, and three messengers, releasable on demand to collect the data. The mooring line itself is classical, with an expandable weight at the sea-bottom to maintain the mooring, an acoustic release to free the mooring line for recovery, a line adjustable to the seafloor depth, and an immerged buoy, holding the acquisition system, to maintain the sensors at a constant depth and to bring the mooring line to the surface for its recovery. The data logger is based on a low-power microprocessor, an A/D-32bit convertor sampling at 250Hz, a 10-8 real time clock and SD card storage. Lithium batteries provide 3-4 years of autonomy. Acoustic communications with the surface-ship provide control over all functionalities at deployment and a health bulletin on demand. The 3 shuttles, encapsulated in 13" glass spheres, use the same CPU board and clock as the main station. Data transfer from the data logger to the shuttles is wireless (1Mbit/s digital inductive through water). Data are duplicated once per day on shuttles N and N+1 for redundancy. Prior to their release by acoustic command, the shuttles are synchronized with the master clock. At sea-surface, shuttles (as the main unit) look for GPS time and calculate their clock drift. So, the master clock drift can be monitored over time at every shuttle release until its final recovery. Shuttles and main unit are located on the sea-surface by AIS. Iridium communications can also be set to warn the user of a false release. A non-specialist can thus easily handle a shuttle recovery from a ship of opportunity. With 4-channels, this system is also suitable to monitor other parameters in the water column, continuously and over long periods.

  1. Expression of an osmotin-like protein from Solanum nigrum confers drought tolerance in transgenic soybean.

    PubMed

    Weber, Ricardo Luís Mayer; Wiebke-Strohm, Beatriz; Bredemeier, Christian; Margis-Pinheiro, Márcia; de Brito, Giovani Greigh; Rechenmacher, Ciliana; Bertagnolli, Paulo Fernando; de Sá, Maria Eugênia Lisei; Campos, Magnólia de Araújo; de Amorim, Regina Maria Santos; Beneventi, Magda Aparecida; Margis, Rogério; Grossi-de-Sa, Maria Fátima; Bodanese-Zanettini, Maria Helena

    2014-12-10

    Drought is by far the most important environmental factor contributing to yield losses in crops, including soybeans [Glycine max (L.) Merr.]. To address this problem, a gene that encodes an osmotin-like protein isolated from Solanum nigrum var. americanum (SnOLP) driven by the UBQ3 promoter from Arabidopsis thaliana was transferred into the soybean genome by particle bombardment. Two independently transformed soybean lines expressing SnOLP were produced. Segregation analyses indicated single-locus insertions for both lines. qPCR analysis suggested a single insertion of SnOLP in the genomes of both transgenic lines, but one copy of the hpt gene was inserted in the first line and two in the second line. Transgenic plants exhibited no remarkable phenotypic alterations in the seven analyzed generations. When subjected to water deficit, transgenic plants performed better than the control ones. Leaf physiological measurements revealed that transgenic soybean plants maintained higher leaf water potential at predawn, higher net CO2 assimilation rate, higher stomatal conductance and higher transpiration rate than non-transgenic plants. Grain production and 100-grain weight were affected by water supply. Decrease in grain productivity and 100-grain weight were observed for both transgenic and non-transgenic plants under water deficit; however, it was more pronounced for non-transgenic plants. Moreover, transgenic lines showed significantly higher 100-grain weight than non-transgenic plants under water shortage. This is the first report showing that expression of SnOLP in transgenic soybeans improved physiological responses and yield components of plants when subjected to water deficit, highlighting the potential of this gene for biotechnological applications.

  2. 21 CFR 165.110 - Bottled water.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    .... (3) Physical quality. Bottled water shall, when a composite of analytical units of equal volume from.... 1 (4) Chemical quality. (i)(A) Bottled water shall, when a composite of analytical units of equal... bottled water, when a composite of analytical units of equal volume from a sample is examined by the...

  3. Surficial aquifer system in eastern Lee County, Florida

    USGS Publications Warehouse

    Boggess, D.H.; Watkins, F.A.

    1986-01-01

    The surficial aquifer system in eastern Lee County consists of an upper water bearing unit, which is generally unconfined, and a lower water bearing unit, which is confined and is the major source tapped by most wells. The top of the lower unit, which is of primary interest in this report, ranges in depth from 40 to 60 ft below land surface in the east-central part of the county to more than 120 ft in the southern part. In the extreme southern part of the county, a middle water bearing unit also contains water under artesian pressure. Recharge to the lower unit occurs primarily by leakage from the overlying saturated section through the confining beds. Water levels in the lower unit fluctuate similarly to those in the upper (unconfined) unit. Groundwater in the lower unit moves from areas of highest water level in the south part of Lehigh acres, northward toward the Caloosahatchee River, and toward the coast. The lower unit contains freshwater throughout much of its extent and is the source of public water supply at Lehigh Acres and Green Meadows where an average of about 3 mil gal/day was withdrawn in 1980. In several areas, the concentrations of chlorides and dissolved solids exceed drinking water standards. Yields of wells that tap the lower unit range from 10 to 1,100 gal/min. Transmissivities ranging from about 17,700 to 7,750 sq ft/day were determined for different areas of the unit. Storage coefficients range from 0.0001 to 0.0003. (Author 's abstract)

  4. Superfund Record of Decision (EPA Region 3): William Dick Lagoons, West Caln Township, Chester County, PA. (First remedial action), June 1991

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1991-09-28

    The 4.4-acre William Dick Lagoons site is a chemical wastewater disposal site in West Caln Township, Chester County, Pennsylvania. An estimated 30 residences located within 1,000 feet of the site use private wells for their drinking water supply. Two other Superfund sites are near the site. From the 1950's to 1970, Mr. William Dick used the lagoons to dispose of wastewater left from cleaning the interiors of chemical and petroleum tank trailers owned primarily by Chemical Leaman Tank Lines, (CLTL), and residual chemical products. Later in 1970, vandalism caused the release of an estimated 300,000 gallons of wastewater into Birchmore » Run, a tributary of the West Branch of Brandywine Creek. As a result of this discharge, more than 2,600 fish died, and water supplies that used Brandywine Creek as a water source were closed. The Record of Decision (ROD) provides an interim remedy and addresses contaminated residential water as Operable Unit 1 (OU1) and ground water as OU2. A future ROD will address source control and will provide a remedy for the cleanup of contaminated soil. The primary contaminants of concern affecting the ground water are VOCs including benzene, PCE, and TCE; other organics including phenols; and metals. The selected remedial action for the site is included.« less

  5. B cell signatures of BCWD-resistant and susceptible lines of rainbow trout: a shift towards more EBF-expressing progenitors and fewer mature B cells in resistant animals

    USDA-ARS?s Scientific Manuscript database

    Bacterial Cold Water Disease (BCWD) is a chronic disease of rainbow trout, and is caused by the gram-negative bacterium Flavobacterium psychrophilum (Fp), a common aquaculture pathogen. The National Center for Cool and Cold Water Aquaculture has bred two genetic lines of rainbow trout: a line of Fp...

  6. A BCWD-resistant line of rainbow trout exhibits higher abundance of IgT+ B cells and heavy chain tau transcripts compared to a susceptible line following challenge with Flavobacterium psychrophilum

    USDA-ARS?s Scientific Manuscript database

    Bacterial Cold Water Disease (BCWD) is a common, chronic disease in rainbow trout, and is caused by the gram-negative bacterium Flavobacterium psychrophilum (Fp). Through selective breeding, the National Center for Cool and Cold Water Aquaculture has generated a genetic line that is highly resistant...

  7. 6. SAWTOOTH WINDOW RANKS ABOVE ASSEMBLY LINES, WATER TOWER, AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. SAWTOOTH WINDOW RANKS ABOVE ASSEMBLY LINES, WATER TOWER, AND SECOND FLOOR WAREHOUSE STRUCTURE. VIEW TO SOUTH-SOUTHEAST. - Ford Motor Company Long Beach Assembly Plant, Assembly Building, 700 Henry Ford Avenue, Long Beach, Los Angeles County, CA

  8. The development of a line-scan imaging algorithm for the detection of fecal contamination on leafy geens

    NASA Astrophysics Data System (ADS)

    Yang, Chun-Chieh; Kim, Moon S.; Chuang, Yung-Kun; Lee, Hoyoung

    2013-05-01

    This paper reports the development of a multispectral algorithm, using the line-scan hyperspectral imaging system, to detect fecal contamination on leafy greens. Fresh bovine feces were applied to the surfaces of washed loose baby spinach leaves. A hyperspectral line-scan imaging system was used to acquire hyperspectral fluorescence images of the contaminated leaves. Hyperspectral image analysis resulted in the selection of the 666 nm and 688 nm wavebands for a multispectral algorithm to rapidly detect feces on leafy greens, by use of the ratio of fluorescence intensities measured at those two wavebands (666 nm over 688 nm). The algorithm successfully distinguished most of the lowly diluted fecal spots (0.05 g feces/ml water and 0.025 g feces/ml water) and some of the highly diluted spots (0.0125 g feces/ml water and 0.00625 g feces/ml water) from the clean spinach leaves. The results showed the potential of the multispectral algorithm with line-scan imaging system for application to automated food processing lines for food safety inspection of leafy green vegetables.

  9. Regenerable Air Purification System for Gas-Phase Contaminant Control

    NASA Technical Reports Server (NTRS)

    Constantinescu, Ileana C.; Finn, John E.; LeVan, M. Douglas; Lung, Bernadette (Technical Monitor)

    2000-01-01

    Tests of a pre-prototype regenerable air purification system (RAPS) that uses water vapor to displace adsorbed contaminants from an adsorbent column have been performed at NASA Ames Research Center. A unit based on this design can be used for removing trace gas-phase contaminants from spacecraft cabin air or from polluted process streams including incinerator exhaust. During the normal operation mode, contaminants are removed from the air on the column. Regeneration of the column is performed on-line. During regeneration, contaminants are displaced and destroyed inside the closed oxidation loop. In this presentation we discuss initial experimental results for the performance of RAPS in the removal and treatment of several important spacecraft contaminant species from air.

  10. Tuneable diode laser gas analyser for methane measurements on a large scale solid oxide fuel cell

    NASA Astrophysics Data System (ADS)

    Lengden, Michael; Cunningham, Robert; Johnstone, Walter

    2011-10-01

    A new in-line, real time gas analyser is described that uses tuneable diode laser spectroscopy (TDLS) for the measurement of methane in solid oxide fuel cells. The sensor has been tested on an operating solid oxide fuel cell (SOFC) in order to prove the fast response and accuracy of the technology as compared to a gas chromatograph. The advantages of using a TDLS system for process control in a large-scale, distributed power SOFC unit are described. In future work, the addition of new laser sources and wavelength modulation will allow the simultaneous measurement of methane, water vapour, carbon-dioxide and carbon-monoxide concentrations.

  11. Boundary Layer Observations of Water Vapor and Aerosol Profiles with an Eye-Safe Micro-Pulse Differential Absorption Lidar (DIAL)

    NASA Astrophysics Data System (ADS)

    Nehrir, A. R.; Repasky, K. S.; Carlsten, J.; Ismail, S.

    2011-12-01

    Measurements of real-time high spatial and temporal resolution profiles of combined water vapor and aerosols in the boundary layer have been a long standing observational challenge to the meteorological, weather forecasting, and climate science communities. To overcome the high reoccurring costs associated with radiosondes as well as the lack of sufficient water vapor measurements over the continental united states, a compact and low cost eye-safe all semiconductor-based micro-pulse differential absorption lidar (DIAL) has been developed for water vapor and aerosol profiling in the lower troposphere. The laser transmitter utilizes two continuous wave external cavity diode lasers operating in the 830 nm absorption band as the online and offline seed laser sources. An optical switch is used to sequentially injection seed a tapered semiconductor optical amplifier (TSOA) with the two seed laser sources in a master oscillator power amplifier (MOPA) configuration. The TSOA is actively current pulsed to produce up to 7 μJ of output energy over a 1 μs pulse duration (150 m vertical resolution) at a 10 kHz pulse repetition frequency. The measured laser transmitter spectral linewidth is less than 500 kHz while the long term frequency stability of the stabilized on-line wavelength is ± 55 MHz. The laser transmitter spectral purity was measured to be greater than 0.9996, allowing for simultaneous measurements of water vapor in the lower and upper troposphere. The DIAL receiver utilizes a commercially available full sky-scanning capable 35 cm Schmidt-Cassegrain telescope to collect the scattered light from the laser transmitter. Light collected by the telescope is spectrally filtered to suppress background noise and is coupled into a fiber optic cable which acts as the system field stop and limits the full angle field of view to 140 μrad. The light is sampled by a fiber coupled APD operated in a Geiger mode. The DIAL instrument is operated autonomously where water vapor and aerosol profiles are displayed in real-time. The transmitter is capable of operating at any spectral position along the selected water vapor absorption line allowing for year round operation at various geographical locations using a single line. Water vapor and aerosol profiles have been recorded up to 6 km and 15 km with 10 m and 1 m temporal averaging, respectively, allowing for mesoscale monitoring of boundary layer dynamics during both daytime and nighttime operation. A brief description of the current status of the water vapor DIAL instrument will be presented. Nighttime and daytime water vapor and aerosol profiles/inversions from the DIAL instrument will also be presented and favorable comparisons against collocated radiosonde, in situ, and column averaged data from SUOMINET and AERONET will also be discussed. A future outlook towards instrument enhancements that will allow the diode-laser-based DIAL technique/technology to become a viable candidate for deployment in multi-point sensor networks will also be discussed.

  12. Line-by-line spectroscopic simulations on graphics processing units

    NASA Astrophysics Data System (ADS)

    Collange, Sylvain; Daumas, Marc; Defour, David

    2008-01-01

    We report here on software that performs line-by-line spectroscopic simulations on gases. Elaborate models (such as narrow band and correlated-K) are accurate and efficient for bands where various components are not simultaneously and significantly active. Line-by-line is probably the most accurate model in the infrared for blends of gases that contain high proportions of H 2O and CO 2 as this was the case for our prototype simulation. Our implementation on graphics processing units sustains a speedup close to 330 on computation-intensive tasks and 12 on memory intensive tasks compared to implementations on one core of high-end processors. This speedup is due to data parallelism, efficient memory access for specific patterns and some dedicated hardware operators only available in graphics processing units. It is obtained leaving most of processor resources available and it would scale linearly with the number of graphics processing units in parallel machines. Line-by-line simulation coupled with simulation of fluid dynamics was long believed to be economically intractable but our work shows that it could be done with some affordable additional resources compared to what is necessary to perform simulations on fluid dynamics alone. Program summaryProgram title: GPU4RE Catalogue identifier: ADZY_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/ADZY_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 62 776 No. of bytes in distributed program, including test data, etc.: 1 513 247 Distribution format: tar.gz Programming language: C++ Computer: x86 PC Operating system: Linux, Microsoft Windows. Compilation requires either gcc/g++ under Linux or Visual C++ 2003/2005 and Cygwin under Windows. It has been tested using gcc 4.1.2 under Ubuntu Linux 7.04 and using Visual C++ 2005 with Cygwin 1.5.24 under Windows XP. RAM: 1 gigabyte Classification: 21.2 External routines: OpenGL ( http://www.opengl.org) Nature of problem: Simulating radiative transfer on high-temperature high-pressure gases. Solution method: Line-by-line Monte-Carlo ray-tracing. Unusual features: Parallel computations are moved to the GPU. Additional comments: nVidia GeForce 7000 or ATI Radeon X1000 series graphics processing unit is required. Running time: A few minutes.

  13. Influence of unit operations on the levels of polyacetylenes in minimally processed carrots and parsnips: An industrial trial.

    PubMed

    Koidis, Anastasios; Rawson, Ashish; Tuohy, Maria; Brunton, Nigel

    2012-06-01

    Carrots and parsnips are often consumed as minimally processed ready-to-eat convenient foods and contain in minor quantities, bioactive aliphatic C17-polyacetylenes (falcarinol, falcarindiol, falcarindiol-3-acetate). Their retention during minimal processing in an industrial trial was evaluated. Carrot and parsnips were prepared in four different forms (disc cutting, baton cutting, cubing and shredding) and samples were taken in every point of their processing line. The unit operations were: peeling, cutting and washing with chlorinated water and also retention during 7days storage was evaluated. The results showed that the initial unit operations (mainly peeling) influence the polyacetylene retention. This was attributed to the high polyacetylene content of their peels. In most cases, when washing was performed after cutting, less retention was observed possibly due to leakage during tissue damage occurred in the cutting step. The relatively high retention during storage indicates high plant matrix stability. Comparing the behaviour of polyacetylenes in the two vegetables during storage, the results showed that they were slightly more retained in parsnips than in carrots. Unit operations and especially abrasive peeling might need further optimisation to make them gentler and minimise bioactive losses. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. A STRONGLY COUPLED REACTOR CORE ISOLATION COOLING SYSTEM MODEL FOR EXTENDED STATION BLACK-OUT ANALYSES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, Haihua; Zhang, Hongbin; Zou, Ling

    2015-03-01

    The reactor core isolation cooling (RCIC) system in a boiling water reactor (BWR) provides makeup cooling water to the reactor pressure vessel (RPV) when the main steam lines are isolated and the normal supply of water to the reactor vessel is lost. The RCIC system operates independently of AC power, service air, or external cooling water systems. The only required external energy source is from the battery to maintain the logic circuits to control the opening and/or closure of valves in the RCIC systems in order to control the RPV water level by shutting down the RCIC pump to avoidmore » overfilling the RPV and flooding the steam line to the RCIC turbine. It is generally considered in almost all the existing station black-out accidents (SBO) analyses that loss of the DC power would result in overfilling the steam line and allowing liquid water to flow into the RCIC turbine, where it is assumed that the turbine would then be disabled. This behavior, however, was not observed in the Fukushima Daiichi accidents, where the Unit 2 RCIC functioned without DC power for nearly three days. Therefore, more detailed mechanistic models for RCIC system components are needed to understand the extended SBO for BWRs. As part of the effort to develop the next generation reactor system safety analysis code RELAP-7, we have developed a strongly coupled RCIC system model, which consists of a turbine model, a pump model, a check valve model, a wet well model, and their coupling models. Unlike the traditional SBO simulations where mass flow rates are typically given in the input file through time dependent functions, the real mass flow rates through the turbine and the pump loops in our model are dynamically calculated according to conservation laws and turbine/pump operation curves. A simplified SBO demonstration RELAP-7 model with this RCIC model has been successfully developed. The demonstration model includes the major components for the primary system of a BWR, as well as the safety system components such as the safety relief valve (SRV), the RCIC system, the wet well, and the dry well. The results show reasonable system behaviors while exhibiting rich dynamics such as variable flow rates through RCIC turbine and pump during the SBO transient. The model has the potential to resolve the Fukushima RCIC mystery after adding the off-design two-phase turbine operation model and other additional improvements.« less

  15. Diagnosable structured logic array

    NASA Technical Reports Server (NTRS)

    Whitaker, Sterling (Inventor); Miles, Lowell (Inventor); Gambles, Jody (Inventor); Maki, Gary K. (Inventor)

    2009-01-01

    A diagnosable structured logic array and associated process is provided. A base cell structure is provided comprising a logic unit comprising a plurality of input nodes, a plurality of selection nodes, and an output node, a plurality of switches coupled to the selection nodes, where the switches comprises a plurality of input lines, a selection line and an output line, a memory cell coupled to the output node, and a test address bus and a program control bus coupled to the plurality of input lines and the selection line of the plurality of switches. A state on each of the plurality of input nodes is verifiably loaded and read from the memory cell. A trusted memory block is provided. The associated process is provided for testing and verifying a plurality of truth table inputs of the logic unit.

  16. SutraGUI, a graphical-user interface for SUTRA, a model for ground-water flow with solute or energy transport

    USGS Publications Warehouse

    Winston, Richard B.; Voss, Clifford I.

    2004-01-01

    This report describes SutraGUI, a flexible graphical user-interface (GUI) that supports two-dimensional (2D) and three-dimensional (3D) simulation with the U.S. Geological Survey (USGS) SUTRA ground-water-flow and transport model (Voss and Provost, 2002). SutraGUI allows the user to create SUTRA ground-water models graphically. SutraGUI provides all of the graphical functionality required for setting up and running SUTRA simulations that range from basic to sophisticated, but it is also possible for advanced users to apply programmable features within Argus ONE to meet the unique demands of particular ground-water modeling projects. SutraGUI is a public-domain computer program designed to run with the proprietary Argus ONE? package, which provides 2D Geographic Information System (GIS) and meshing support. For 3D simulation, GIS and meshing support is provided by programming contained within SutraGUI. When preparing a 3D SUTRA model, the model and all of its features are viewed within Argus 1 in 2D projection. For 2D models, SutraGUI is only slightly changed in functionality from the previous 2D-only version (Voss and others, 1997) and it provides visualization of simulation results. In 3D, only model preparation is supported by SutraGUI, and 3D simulation results may be viewed in SutraPlot (Souza, 1999) or Model Viewer (Hsieh and Winston, 2002). A comprehensive online Help system is included in SutraGUI. For 3D SUTRA models, the 3D model domain is conceptualized as bounded on the top and bottom by 2D surfaces. The 3D domain may also contain internal surfaces extending across the model that divide the domain into tabular units, which can represent hydrogeologic strata or other features intended by the user. These surfaces can be non-planar and non-horizontal. The 3D mesh is defined by one or more 2D meshes at different elevations that coincide with these surfaces. If the nodes in the 3D mesh are vertically aligned, only a single 2D mesh is needed. For nonaligned meshes, two or more 2D meshes of similar connectivity are used. Between each set of 2D meshes (and model surfaces), the vertical space in the 3D mesh is evenly divided into a user-specified number of layers of finite elements. Boundary conditions may be specified for 3D models in SutraGUI using a variety of geometric shapes that may be located freely within the 3D model domain. These shapes include points, lines, sheets, and solids. These are represented by 2D contours (within the vertically-projected Argus ONE view) with user-defined elevations. In addition, boundary conditions may be specified for 3D models as points, lines, and areas that are located exactly within the surfaces that define the model top and the bottoms of the tabular units. Aquifer properties may be specified separately for each tabular unit. If the aquifer properties vary vertically within a unit, SutraGUI provides the Sutra_Z function that can be used to specify such variation.

  17. 46 CFR 108.597 - Line-throwing appliance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Line-throwing appliance. 108.597 Section 108.597... AND EQUIPMENT Lifesaving Equipment § 108.597 Line-throwing appliance. (a) General. Each unit in international service must have a line-throwing appliance that is approved under approval series 160.040. Each...

  18. 76 FR 9608 - Certain Welded Large Diameter Line Pipe From Mexico

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-18

    ... Large Diameter Line Pipe From Mexico AGENCY: United States International Trade Commission. ACTION... duty order on certain welded large diameter line pipe from Mexico. For further information concerning... welded large diameter line pipe from Mexico would not be likely to lead to continuation or recurrence of...

  19. Pore-Water Quality in the Clay-Silt Confining Units of the Lower Miocene Kirkwood Formation and Hypothetical Effects on Water Quality in the Atlantic City 800-Foot Sand, Northeastern Cape May County, New Jersey, 2001

    USGS Publications Warehouse

    Szabo, Zoltan; Keller, Elizabeth A.; Defawe, Rose M.

    2006-01-01

    Pore water was extracted from clay-silt core samples collected from a borehole at Ocean View, west of Sea Isle City, in northeastern Cape May County, New Jersey. The borehole intersects the lower Miocene Kirkwood Formation, which includes a thick sand and gravel unit between two clay-silt units. The sand and gravel unit forms a major confined aquifer in the region, known as the Atlantic City 800-foot sand, the major source of potable water along the Atlantic Coast of southern New Jersey. The pore water from the core is of interest because the borehole intersects the aquifer in an area where the ground water is sodium-rich and sulfidic. Locally in the aquifer in central and southern Cape May County, sodium concentrations are near the New Jersey secondary drinking-water standard of 50 mg/L (milligrams per liter), and typically are greater than 30 mg/L, but chloride and sulfate do not approach their respective secondary drinking-water standards except in southernmost Cape May County. Pore waters from the confining units are suspected to be a source of sodium, sulfur, and chloride to the aquifer. Constituent concentrations in filtered pore-water samples were determined using the inductively coupled plasma-mass spectrometry analytical technique to facilitate the determination of low-level concentrations of many trace constituents. Calcium-sodium-sulfate-bicarbonate, calcium-chloride-sulfate, calcium-sulfate, and sodium-sulfate-chloride-bicarbonate type waters characterize samples from the deepest part of the confining unit directly overlying the aquifer (termed the 'lower' confining unit). A sodium-chloride-sulfate type water is dominant in the composite confining unit below the aquifer. Sodium, chloride, and sulfate became increasingly dominant with depth. Pore water from the deepest sample recovered (1,390 ft (feet) below land surface) was brackish, with concentrations of sodium, chloride, and sulfate of 5,930, 8,400, and 5,070 mg/L, respectively. Pore-water samples from 900 ft or less below land surface, although mineralized, were fresh, not brackish. Sodium concentrations ranged from 51.3 to 513 mg/L, with the maximum concentration found at 882 ft below land surface in the composite confining unit below the aquifer. Chloride concentrations ranged from 46.4 to 757 mg/L, with the maximum concentration found at 596 ft below land surface in the 'lower' confining unit, and were higher than those in pore water from the same units at Atlantic City, N.J. Concentrations of chloride in the composite confining unit below the aquifer were consistently greater than 250 mg/L, indicating that the confining unit can be a source of chloride at depth. Of the major anions, sulfate was the constituent whose concentration varied most, ranging from 42 to 799 mg/L. The maximum concentration was found at 406 ft below land surface, in the upper part of the confining unit overlying the aquifer and the Rio Grande water-bearing zone (termed the 'upper' confining unit). Sulfide was not detected in any pore-water sample despite the presence of abundant quantities of sulfate and sulfide in the aquifer. The absence of sulfide in the pore waters is consistent with the hypothesis that sulfate is reduced in the aquifer. The presence of arsenic, at concentrations ranging from 0.0062 to 0.0374 mg/L, is consistent with the absence of sulfide and the possible presence of iron in the pore water.

  20. Ground-water data collected in the Missouri River Basin units in Kansas during 1953

    USGS Publications Warehouse

    Mason, B.J.

    1954-01-01

    Ground-water studies in the Missouri River basin were begun by the United States Geological Survey during the fall of 1945 as a part of a program for the development of the resources of the basin by the United States Bureau of Reclamation and other Federal Agencies. The studies of the ground-water resources in the part of Kansas that lies within the Missouri River basin have been coordinated with the cooperative program of ground water studies which were already being made in Kansas by the U. S. Geological Survey, the State Geological Survey of Kansas, the Division of Sanitation of the Kansas State Board of Health, and the Division of Water Resources of the Kansas State Board of Agriculture.Areas in which ground-water data have been and are being collected are the following: Almena unit in Norton and Phillips Counties; Bostwick unit in Jewell, Republic, and Cloud Counties; Cedar Bluff unit in Ellis, Rush, and Trego Counties; Glen Elder unit in Mitchell County; Kanopolis unit in Ellsworth, McPherson, and Saline Counties; Kirwin unit in Phillips, Smiths and Osborne Counties; St. Francis unit in Cheyenne County; Webster unit in Osborne County; and Wilson unit in Lincoln County. (See fig. 1.) Data relating to the Ladder Creek project in Greeley, Gove, Lane, Logan, Scott, Wallace, and Wichita Counties will be published later in a separate report.

  1. Geohydrology of the lower Apalachicola-Chattahoochee-Flint River basin, southwestern Georgia, northwestern Florida, and southeastern Alabama

    USGS Publications Warehouse

    Torak, Lynn J.; Painter, Jaime A.

    2006-01-01

    The lower Apalachicola-Chattahoochee-Flint (ACF) River Basin contains about 4,600 square miles of karstic and fluvial plains and nearly 100,000 cubic miles of predominantly karst limestone connected hydraulically to the principal rivers and lakes in the Coastal Plain of southwestern Georgia, northwestern Florida, and southwestern Alabama. Sediments of late-middle Eocene to Holocene in hydraulic connection with lakes, streams, and land surface comprise the surficial aquifer system, upper semiconfining unit, Upper Floridan aquifer, and lower semiconfining unit and contribute to the exchange of ground water and surface water in the stream-lake-aquifer flow system. Karst processes, hydraulic properties, and stratigraphic relations limit ground-water and surface-water interaction to the following hydrologic units of the stream-lake-aquifer flow system: the surficial aquifer system, upper semiconfining unit, Upper Floridan aquifer, and lower confining unit. Geologic units corresponding to these hydrologic units are, in ascending order: Lisbon Formation; Clinchfield Sand; Ocala, Marianna, Suwannee, and Tampa Limestones; Hawthorn Group; undifferentiated overburden (residuum); and terrace and undifferentiated (surficial) deposits. Similarities in hydraulic properties and direct or indirect interaction with surface water allow grouping sediments within these geologic units into the aforementioned hydrologic units, which transcend time-stratigraphic classifications and define the geohydrologic framework for the lower ACF River Basin. The low water-transmitting properties of the lower confining unit, principally the Lisbon Formation, allow it to act as a nearly impermeable base to the stream-lake-aquifer flow system. Hydraulic connection of the surficial aquifer system with surface water and the Upper Floridan aquifer is direct where sandy deposits overlie the limestone, or indirect where fluvial deposits overlie clayey limestone residuum. The water level in perched zones within the surficial aquifer system fluctuates independently of water-level changes in the underlying aquifer, adjacent streams, or lakes. Where the surficial aquifer system is connected with surface water and the Upper Floridan aquifer, water-table fluctuations parallel those in adjacent streams or the underlying aquifer. More...

  2. A digital model for planning water management at Benton Lake National Wildlife Refuge, west-central Montana

    USGS Publications Warehouse

    Nimick, David A.; McCarthy, Peter M.; Fields, Vanessa

    2011-01-01

    Benton Lake National Wildlife Refuge is an important area for waterfowl production and migratory stopover in west-central Montana. Eight wetland units covering about 5,600 acres are the essential features of the refuge. Water availability for the wetland units can be uncertain owing to the large natural variations in precipitation and runoff and the high cost of pumping supplemental water. The U.S. Geological Survey, in cooperation with the U.S. Fish and Wildlife Service, has developed a digital model for planning water management. The model can simulate strategies for water transfers among the eight wetland units and account for variability in runoff and pumped water. This report describes this digital model, which uses a water-accounting spreadsheet to track inputs and outputs to each of the wetland units of Benton Lake National Wildlife Refuge. Inputs to the model include (1) monthly values for precipitation, pumped water, runoff, and evaporation; (2) water-level/capacity data for each wetland unit; and (3) the pan-evaporation coefficient. Outputs include monthly water volume and flooded surface area for each unit for as many as 5 consecutive years. The digital model was calibrated by comparing simulated and historical measured water volumes for specific test years.

  3. Disinfection of Contaminated Water by Using Solar Irradiation

    PubMed Central

    Caslake, Laurie F.; Connolly, Daniel J.; Menon, Vilas; Duncanson, Catriona M.; Rojas, Ricardo; Tavakoli, Javad

    2004-01-01

    Contaminated water causes an estimated 6 to 60 billion cases of gastrointestinal illness annually. The majority of these cases occur in rural areas of developing nations where the water supply remains polluted and adequate sanitation is unavailable. A portable, low-cost, and low-maintenance solar unit to disinfect unpotable water has been designed and tested. The solar disinfection unit was tested with both river water and partially processed water from two wastewater treatment plants. In less than 30 min in midday sunlight, the unit eradicated more than 4 log10 U (99.99%) of bacteria contained in highly contaminated water samples. The solar disinfection unit has been field tested by Centro Panamericano de Ingenieria Sanitaria y Ciencias del Ambiente in Lima, Peru. At moderate light intensity, the solar disinfection unit was capable of reducing the bacterial load in a controlled contaminated water sample by 4 log10 U and disinfected approximately 1 liter of water in 30 min. PMID:14766599

  4. Potential Implications of Approaches to Climate Change on the Clean Water Rule Definition of "Waters of the United States".

    PubMed

    Faust, Derek R; Moore, Matthew T; Emison, Gerald Andrews; Rush, Scott A

    2016-05-01

    The 1972 Clean Water Act was passed to protect chemical, physical, and biological integrity of United States' waters. The U.S. Environmental Protection Agency and U.S. Army Corps of Engineers codified a new "waters of the United States" rule on June 29, 2015, because several Supreme Court case decisions caused confusion with the existing rule. Climate change could affect this rule through connectivity between groundwater and surface waters; floodplain waters and the 100-year floodplain; changes in jurisdictional status; and sea level rise on coastal ecosystems. Four approaches are discussed for handling these implications: (1) "Wait and see"; (2) changes to the rule; (3) use guidance documents; (4) Congress statutorily defining "waters of the United States." The approach chosen should be legally defensible and achieved in a timely fashion to provide protection to "waters of the United States" in proactive consideration of scientifically documented effects of climate change on aquatic ecosystems.

  5. Microstructure characterization of a food-grade U-type microemulsion system by differential scanning calorimetry and electrical conductivity techniques.

    PubMed

    Zhang, Hui; Taxipalati, Maierhaba; Que, Fei; Feng, Fengqin

    2013-12-01

    The microstructure transitions of a food-grade U-type microemulsion system containing glycerol monolaurate and propionic acid at a 1:1 mass ratio as oil phase and Tween 80 as surfactant were investigated along a water dilution line at a ratio of 80:20 mass% surfactant/oil phase, based on a previously studied phase diagram. From the water thermal behaviours detected by differential scanning calorimetry, three structural regions are identified along the dilution line. In the first region, all water molecules are confined to the water core of the reverse micelles, leading to the formation of w/o microemulsion. As the water content increases, the water gains mobility, transforms into bicontinuous in the second region, and finally the microemulsion become o/w in the third region. The thermal transition points coincide with the structural phase transitions by electrical conductivity measurements, indicating that the structural transitions occur at 35 and 65 mass% of water along the dilution line. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Geohydrology of the Aucilla-Suwannee-Ochlockonee River Basin, south-central Georgia and adjacent parts of Florida

    USGS Publications Warehouse

    Torak, Lynn J.; Painter, Jaime A.; Peck, Michael F.

    2010-01-01

    Major streams and tributaries located in the Aucilla-Suwannee-Ochlockonee (ASO) River Basin of south-central Georgia and adjacent parts of Florida drain about 8,000 square miles of a layered sequence of clastic and carbonate sediments and carbonate Coastal Plain sediments consisting of the surficial aquifer system, upper semiconfining unit, Upper Floridan aquifer, and lower confining unit. Streams either flow directly on late-middle Eocene to Oligocene karst limestone or carve a dendritic drainage pattern into overlying Miocene to Holocene sand, silt, and clay, facilitating water exchange and hydraulic connection with geohydrologic units. Geologic structures operating in the ASO River Basin through time control sedimentation and influence geohydrology and water exchange between geohydrologic units and surface water. More than 300 feet (ft) of clastic sediments overlie the Upper Floridan aquifer in the Gulf Trough-Apalachicola Embayment, a broad area extending from the southwest to the northeast through the center of the basin. These clastic sediments limit hydraulic connection and water exchange between the Upper Floridan aquifer, the surficial aquifer system, and surface water. Accumulation of more than 350 ft of low-permeability sediments in the Southeast Georgia Embayment and Suwannee Strait hydraulically isolates the Upper Floridan aquifer from land-surface hydrologic processes in the Okefenokee Basin physiographic district. Burial of limestone beneath thick clastic overburden in these areas virtually eliminates karst processes, resulting in low aquifer hydraulic conductivity and storage coefficient despite an aquifer thickness of more than 900 ft. Conversely, uplift and faulting associated with regional tectonics and the northern extension of the Peninsular Arch caused thinning and erosion of clastic sediments overlying the Upper Floridan aquifer southeast of the Gulf Trough-Apalachicola Embayment near the Florida-Georgia State line. Limestone dissolution in Brooks and Lowndes Counties, Ga., create karst features that enhance water-transmitting and storage properties of the Upper Floridan aquifer, promoting groundwater recharge and water exchange between the aquifer, land surface, and surface water. Structural control of groundwater flow and hydraulic properties combine with climatic effects and increased hydrologic stress from agricultural pumpage to yield unprecedented groundwater-level decline in the northwestern and central parts of the ASO River Basin. Hydrographs from continuous-record observation wells in these regions document declining groundwater levels, indicating diminished water-resource potential of the Upper Floridan aquifer through time. More than 24 ft of groundwater-level decline occurred along the basin's northwestern boundary with the lower Apalachicola-Chattahoochee-Flint River Basin, lowering hydraulic gradients that provide the potential for groundwater flow into the ASO River Basin and southeastward across the Gulf Trough-Apalachicola Embayment region. Slow-moving groundwater across the trough-embayment region coupled with downward-vertical flow from upper to lower limestone units composing the Upper Floridan aquifer resulted in 40-50 ft of groundwater-level decline since 1969 in southeastern Colquitt County. Multi-year episodes of dry climatic conditions during the 1980s through the early 2000s contributed to seasonal and long-term groundwater-level decline by reducing recharge to the Upper Floridan aquifer and increasing hydrologic stress by agricultural pumpage. Unprecedented and continued groundwater-level decline since 1969 caused 40-50 ft of aquifer dewatering in southeastern Colquitt County that reduced aquifer transmissivity and the ability to supply groundwater to wells, resulting in depletion of the groundwater resource.

  7. 78 FR 67336 - Habitat Conservation Plan for the United Water Conservation District, Santa Clara River Watershed...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-12

    ... incidental take permits for United's construction, operations, and maintenance of water management facilities... maintenance of the Freeman Diversion; diversion of water from the Santa Clara River; vegetation management... current and future water management activities. United intends to request a 50-year permit covering five...

  8. The Widom line and dynamical crossover in supercritical water: Popular water models versus experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Corradini, D.; Rovere, M.; Gallo, P., E-mail: gallop@fis.uniroma3.it

    2015-09-21

    In a previous study [Gallo et al., Nat. Commun. 5, 5806 (2014)], we have shown an important connection between thermodynamic and dynamical properties of water in the supercritical region. In particular, by analyzing the experimental viscosity and the diffusion coefficient obtained in simulations performed using the TIP4P/2005 model, we have found that the line of response function maxima in the one phase region, the Widom line, is connected to a crossover from a liquid-like to a gas-like behavior of the transport coefficients. This is in agreement with recent experiments concerning the dynamics of supercritical simple fluids. We here show howmore » different popular water models (TIP4P/2005, TIP4P, SPC/E, TIP5P, and TIP3P) perform in reproducing thermodynamic and dynamic experimental properties in the supercritical region. In particular, the comparison with experiments shows that all the analyzed models are able to qualitatively predict the dynamical crossover from a liquid-like to a gas-like behavior upon crossing the Widom line. Some of the models perform better in reproducing the pressure-temperature slope of the Widom line of supercritical water once a rigid shift of the phase diagram is applied to bring the critical points to coincide with the experimental ones.« less

  9. SOFIA Water Vapor Monitor Design

    NASA Technical Reports Server (NTRS)

    Cooper, R.; Roellig, T. L.; Yuen, L.; Shiroyama, B.; Meyer, A.; Devincenzi, D. (Technical Monitor)

    2002-01-01

    The SOFIA Water Vapor Monitor (WVM) is a heterodyne radiometer designed to determine the integrated amount of water vapor along the telescope line of sight and directly to the zenith. The basic technique that was chosen for the WVM uses radiometric measurements of the center and wings of the 183.3 GHz rotational line of water to measure the water vapor. The WVM reports its measured water vapor levels to the aircraft Mission Controls and Communication System (MCCS) while the SOFIA observatory is in normal operation at flight altitude. The water vapor measurements are also available to other scientific instruments aboard the observatory. The electrical, mechanical and software design of the WVM are discussed.

  10. Fragile to strong crossover and Widom line in supercooled water: A comparative study

    NASA Astrophysics Data System (ADS)

    De Marzio, Margherita; Camisasca, Gaia; Rovere, Mauro; Gallo, Paola

    2018-02-01

    The aim of this paper is to discuss the relationship between the dynamics and thermodynamics of water in the supercooled region. Reviewed case studies comprehend bulk water simulated with the SPC/E, TIP4P and TIP4P/2005 potentials, water at protein interfaces, and water in solution with electrolytes. Upon supercooling, the fragile to strong crossover in the α-relaxation of water is found to occur when the Widom line emanating from the liquid-liquid critical point is crossed. This appears to be a general characteristic of supercooled water, not depending on the applied interaction potential and/or different local environments.

  11. Contact lines on silicone elastomers promote contamination

    NASA Astrophysics Data System (ADS)

    Hourlier-Fargette, Aurelie; Antkowiak, Arnaud; Neukirch, Sebastien

    2017-11-01

    Silicone elastomers are used in contact with aqueous liquids in a large range of applications. Due to numerous advantages such as its flexibility, optical transparency, or gas permeability, polydimethylsiloxane is widely spread in rapid prototyping for microfluidics or elastocapillarity experiments. However, silicone elastomers are known to contain a small fraction of uncrosslinked low-molecular-weight oligomers, the effects of which are not completely understood. We show that in various setups involving an air-water-silicone elastomer contact line, a capillarity-induced extraction of uncrosslinked oligomers occurs, leading to a contamination of water-air interfaces. We investigate the case of a static air-water-PDMS contact line, before focusing on moving contact lines. A water droplet sliding down on a PDMS inclined plane or an air bubble rising on an immersed PDMS plane exhibits two successive speed regimes: the second regime is reached only when a monolayer of oligomers completely covers the water-air interface. These experiments involve processes occurring at the polymer network scale that have significant macroscopic consequences, and therefore provide a simple test to evaluate the presence of uncrosslinked oligomers in an elastomer sample.

  12. Accounting for Genotype-by-Environment Interactions and Residual Genetic Variation in Genomic Selection for Water-Soluble Carbohydrate Concentration in Wheat.

    PubMed

    Ovenden, Ben; Milgate, Andrew; Wade, Len J; Rebetzke, Greg J; Holland, James B

    2018-05-31

    Abiotic stress tolerance traits are often complex and recalcitrant targets for conventional breeding improvement in many crop species. This study evaluated the potential of genomic selection to predict water-soluble carbohydrate concentration (WSCC), an important drought tolerance trait, in wheat under field conditions. A panel of 358 varieties and breeding lines constrained for maturity was evaluated under rainfed and irrigated treatments across two locations and two years. Whole-genome marker profiles and factor analytic mixed models were used to generate genomic estimated breeding values (GEBVs) for specific environments and environment groups. Additive genetic variance was smaller than residual genetic variance for WSCC, such that genotypic values were dominated by residual genetic effects rather than additive breeding values. As a result, GEBVs were not accurate predictors of genotypic values of the extant lines, but GEBVs should be reliable selection criteria to choose parents for intermating to produce new populations. The accuracy of GEBVs for untested lines was sufficient to increase predicted genetic gain from genomic selection per unit time compared to phenotypic selection if the breeding cycle is reduced by half by the use of GEBVs in off-season generations. Further, genomic prediction accuracy depended on having phenotypic data from environments with strong correlations with target production environments to build prediction models. By combining high-density marker genotypes, stress-managed field evaluations, and mixed models that model simultaneously covariances among genotypes and covariances of complex trait performance between pairs of environments, we were able to train models with good accuracy to facilitate genetic gain from genomic selection. Copyright © 2018 Ovenden et al.

  13. On the cost of approximating and recognizing a noise perturbed straight line or a quadratic curve segment in the plane. [central processing units

    NASA Technical Reports Server (NTRS)

    Cooper, D. B.; Yalabik, N.

    1975-01-01

    Approximation of noisy data in the plane by straight lines or elliptic or single-branch hyperbolic curve segments arises in pattern recognition, data compaction, and other problems. The efficient search for and approximation of data by such curves were examined. Recursive least-squares linear curve-fitting was used, and ellipses and hyperbolas are parameterized as quadratic functions in x and y. The error minimized by the algorithm is interpreted, and central processing unit (CPU) times for estimating parameters for fitting straight lines and quadratic curves were determined and compared. CPU time for data search was also determined for the case of straight line fitting. Quadratic curve fitting is shown to require about six times as much CPU time as does straight line fitting, and curves relating CPU time and fitting error were determined for straight line fitting. Results are derived on early sequential determination of whether or not the underlying curve is a straight line.

  14. Mapping Evapotranspiration Units in the Basin and Range Carbonate-Rock Aquifer System, White Pine County, Nevada, and Adjacent Areas in Nevada and Utah

    USGS Publications Warehouse

    Smith, J. LaRue; Laczniak, Randell J.; Moreo, Michael T.; Welborn, Toby L.

    2007-01-01

    Accurate estimates of ground-water discharge are crucial in the development of a water budget for the Basin and Range carbonate-rock aquifer system study area. One common method used throughout the southwestern United States is to estimate ground-water discharge from evapotranspiration (ET). ET is a process by which water from the Earth's surface is transferred to the atmosphere. The volume of water lost to the atmosphere by ET can be computed as the product of the ET rate and the acreage of vegetation, open water, and moist soil through which ET occurs. The procedure used in the study groups areas of similar vegetation, water, and soil conditions into different ET units, assigns an average annual ET rate to each unit, and computes annual ET from each ET unit within the outer extent of potential areas of ground-water discharge. Data sets and the procedures used to delineate the ET-unit map used to estimate ground-water discharge from the study area and a qualitative assessment of the accuracy of the map are described in this report.

  15. Water characteristics associated with the occurrence of Legionella pneumophila in dental units.

    PubMed

    Zanetti, F; Stampi, S; De Luca, G; Fateh-Moghadam, P; Antonietta, M; Sabattini, B; Checchi, L

    2000-02-01

    This study evaluated the incidence of Legionella pneumophila in dental unit water samples and investigated how the occurrence of these bacteria may be related to some physical, chemical and bacteriological characteristics of the water. The samples were taken from the incoming tap water, oral rinsing cup, air-water syringe, ultrasonic scaler, and the turbine of 23 dental units of private and public institutions. Apart from L. pneumophila (serogroup 1 and 3) isolated in 22 out of the 101 (21.8%) water samples tested, two other species were found: L. bozemanii and L. dumoffii. The highest densities and frequency of L. pneumophila were observed in the water coming into the units and in the dental units of public institutions. A negative association between L. pneumophila and 36 degrees C and 22 degrees C heterotrophic total plate counts and other gram-negative bacteria was found. An inverse association between the concentration of L. pneumophila and water temperature was also observed. The values of pH and total hardness did not show any significant difference in the L. pneumophila-positive and -negative dental unit waters. Finally, the chemical oxygen demand (COD) and residual chlorine were found to correlate positively with L. pneumophila.

  16. Employing TDMA Protocol in Neural Nanonetworks in Case of Neuron Specific Faults.

    PubMed

    Tezcan, Hakan; Oktug, Sema F; Kök, Fatma Neşe

    2015-09-01

    Many neurodegenerative diseases arise from the malfunctioning neurons in the pathway where the signal is carried. In this paper, we propose neuron specific TDMA/multiplexing and demultiplexing mechanisms to convey the spikes of a receptor neuron over a neighboring path in case of an irreversible path fault existing in its original path. The multiplexing mechanism depends on neural delay box (NDB) which is composed of a relay unit and a buffering unit. The relay unit can be realized as a nanoelectronic device. The buffering unit can be implemented either via neural delay lines as employed in optical switching systems or via nanoelectronic delay lines, i.e., delay flip flops. Demultiplexing is realized by a demultiplexer unit according to the time slot assignment information. Besides, we propose the use of neural interfaces in the NDBs and the demultiplexer unit for detecting and stimulating the generation of spikes. The objective of the proposed mechanisms is to substitute a malfunctioning path, increase the number of spikes delivered and correctly deliver the spikes to the intended part of the somatosensory cortex. The results demonstrate that significant performance improvement on the successively delivered number of spikes is achievable when delay lines are employed as neural buffers in NDBs.

  17. 15 CFR Appendix B to Subpart M of... - Zones Within the Sanctuary Where Overflights Below 1000 Feet Are Prohibited

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... high water to 3 nautical miles (nmi) offshore between a line extending from Point Santa Cruz on a southwesterly bearing of 220° true and a line extending from 2.0 nmi north of Pescadero Point on a southwesterly bearing of 240° true; (2) From mean high water to 3 nmi offshore between a line extending from the Carmel...

  18. 15 CFR Appendix B to Subpart M of... - Zones Within the Sanctuary Where Overflights Below 1000 Feet Are Prohibited

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... high water to 3 nautical miles (nmi) offshore between a line extending from Point Santa Cruz on a southwesterly bearing of 220° true and a line extending from 2.0 nmi north of Pescadero Point on a southwesterly bearing of 240° true; (2) From mean high water to 3 nmi offshore between a line extending from the Carmel...

  19. 15 CFR Appendix B to Subpart M of... - Zones Within the Sanctuary Where Overflights Below 1000 Feet Are Prohibited

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... high water to 3 nautical miles (nmi) offshore between a line extending from Point Santa Cruz on a southwesterly bearing of 220° true and a line extending from 2.0 nmi north of Pescadero Point on a southwesterly bearing of 240° true; (2) From mean high water to 3 nmi offshore between a line extending from the Carmel...

  20. Border Protection and National Security of Mongolia

    DTIC Science & Technology

    2006-09-01

    Annals of the Association of American Geographers 49:3 (1959): 241–55. 11 These boundaries often correspond to the natural steppe versus cultivated... natural resources (oil, fertile land, or water) within the territory, physical characteristics (a deep-water port or a defensible ridge line), or a... natural boundaries and artificial boundaries. Lines marked by nature , such as mountain crests, rivers, and the shore lines of lakes and seas, have long

  1. Optical transmission measurements for in-line monitoring of turbid oil-water emulsions

    NASA Astrophysics Data System (ADS)

    Metz, Philipp; Dopf, Katja; Aichholz, Markus; Riedel, Boris; Lemmer, Uli; Freudig, Barbara; Zimmermann, Clifton; Gerken, Martina

    2014-05-01

    For absorbing media the concentration may be calculated directly from the optical transmission following the logarithmic dependence given in the Lambert-Beer law. Due to multiple scattering events in oil-water emulsions (e.g. milk, cream, etc.), these exhibit a nonlinear relationship between the attenuation and the oil concentration. We demonstrate that for increasing oil content in oil-water emulsions the attenuation first increases, then levels out, and finally even decreases for a fat content of 60%. Single-wavelength optical transmission measurements are found to be well suited for the in-line monitoring of oil-water emulsions of fat contents below 20%, e.g., for the in-line fat content monitoring of milk. Using experiments and ray-tracing simulations we evaluate system optimization.

  2. Review of Available Water-Quality Data for the Southern Colorado Plateau Network and Characterization of Water Quality in Five Selected Park Units in Arizona, Colorado, New Mexico, and Utah, 1925 to 2004

    USGS Publications Warehouse

    Brown, Juliane B.

    2008-01-01

    Historical water-quality data in the National Park Service Southern Colorado Plateau Network have been collected irregularly and with little followup interpretation, restricting the value of the data. To help address these issues, to inform future water-quality monitoring planning efforts, and to address relevant National Park Service Inventory and Monitoring Program objectives, the U.S. Geological Survey, in cooperation with the National Park Service, compiled, reviewed, and summarized available historical water-quality data for 19 park units in the Southern Colorado Plateau Network. The data are described in terms of availability by major water-quality classes, park unit, site type, and selected identified water sources. The report also describes the geology, water resources, water-quality issues, data gaps, and water-quality standard exceedances identified in five of the park units determined to be of high priority. The five park units are Bandelier National Monument in New Mexico, Canyon de Chelly National Monument in Arizona, Chaco Culture National Historical Park in New Mexico, Glen Canyon National Recreation Area in Arizona and Utah, and Mesa Verde National Park in Colorado. Statistical summaries of water-quality characteristics are presented and considerations for future water-quality monitoring are provided for these five park units.

  3. Modelling water in the envelopes of low-mass protostars

    NASA Astrophysics Data System (ADS)

    van Kempen, Tim A.; Jørgensen, Jes K.; Hogerheijde, Michiel R.; van Dishoeck, Ewine F.

    Using sophisticated spherically symmetric radiative transfer models for gas and dust, we simulate the emission of H2O and its isotopes for the circumstellar envelopes around class 0 protostars, as preparatory science for the ESA cornerstone mission Herschel and its spectrometer, HIFI. L483mm is taken as an example. We probe a wide range of models in which dust, freeze-out and a large variety of abundance structures and optical depths are taken into account. A sample of water lines is selected that are observable by Herschel. Expected fluxes for these lines are derived from the models, convolved with the Herschel beam size. 1. Introduction Water has been detected by the LWS instruments aboard ISO in low-mass protostars (e.g. Ceccarelli et al. 1999, Giannini et al. 2001). The origin of the water lines is still subject of discussion, however. It has been theorized to originate in both the outflow and the quiescent infalling envelope. Ceccarelli et al. (1999) place the water in the small (200 AU), dense (> 107cm-3) and warm (> 100 K) region of the protostellar envelope. The ESA Herschel mission and in particular the HIFI instrument are particularly well suited to observe rotational far-infrared and submillimeter water lines in these environments and test the various models. 2. Approach We started with the physical structure deduced by Jørgensen (2004) for L483mm (Lbol = 9Lsol, Menv10K = 4.4Msol, D=200 pc), giving the density and temperature profiles for a typical protostellar envelope. These profiles are the result of a dust radiative transfer calculation with DUSTY (Ivezic & Elitzur, 1997). The line radiative transfer is subsequently calculated through RATRAN, developed by Hogerheijde & van der Tak (2000). The dust to gas ratio has been set at 1:100, the dust opacities are approximated by the OH5 (Ossenkopf & Henning 1994) at a density of 106cm-3. To simulate the abundance of the water molecule, we have used trial abundances with the assumption that water freezes out onto the dust grains below 90 K (Boonman et al. 2003) (Figure 1). Currently no velocity profile except a turbulent line width of 0.8 km/s is included in the models. The trial abundances range from 10-8 to 10-6 in the region with T < 90 K (Xd) and from 10-6 to 10-4 for the region with T > 90 K (X0, both relative to the H2 abundance). Using RATRAN one can simulate the predicted line profiles and fluxes, convolved with the Herschel beam. We consider all lines observable by HIFI, except those which are likely to maser. 3. Results The line fluxes of water depend strongly on the abundances in both regions as seen in Figure 2. Results for optically thin isotopes such as H182O show that the excited lines are sensitive to the region with T > 90 K, so these lines would be well suited to probe X0 in the inner regions.

  4. Fault Lines in Our Democracy: Civic Knowledge, Voting Behavior, and Civic Engagement in the United States

    ERIC Educational Resources Information Center

    Coley, Richard J.; Sum, Andrew

    2012-01-01

    As the 21st century unfolds, the United States faces historic challenges, including a struggling economy, an aging infrastructure and global terrorism. Solutions will have to come from educated, skilled citizens who understand and believe in our democratic system and are civically engaged. This incisive new report examines these fault lines and…

  5. Fault Lines in Our Democracy: Civic Knowledge, Voting Behavior, and Civic Engagement in the United States. Highlights

    ERIC Educational Resources Information Center

    Coley, Richard J.; Sum, Andrew

    2012-01-01

    As the 21st century unfolds, the United States faces historic challenges, including a struggling economy, an aging infrastructure and global terrorism. Solutions will have to come from educated, skilled citizens who understand and believe in our democratic system and are civically engaged. This incisive new report examines these fault lines and…

  6. Classification, Social Contracts, Obligations, Civil Rights, and the Supreme Court: Sutton v. United Air Lines.

    ERIC Educational Resources Information Center

    Turnbull, H. Rutherford, III; Stowe, Matthew J.

    2001-01-01

    This article analyzes the 1999 decision of the U.S. Supreme Court, Sutton v. United Air Lines, as it pertains to people with disabilities, especially students covered by federal education and civil rights legislation. It sets out implications of the decision for special and general educators as they engage in Individualized Education Program…

  7. Delaware River Basin

    USGS Publications Warehouse

    Fischer, Jeffrey M.

    1999-01-01

    Assessing the quality of water in every location of the Nation would not be practical. Therefore, NAWQA investigations are conducted within 59 selected areas called study units (fig. 1). These study units encompass important river and aquifer systems in the United States and represent the diverse geographic, waterresource, land-use, and water-use characteristics of the Nation. The Delaware River Basin is one of 15 study units in which work began in 1996. Water-quality sampling in the study unit will begin in 1999. This fact sheet provides a brief overview of the NAWQA program, describes the Delaware River Basin study unit, identifies the major water-quality issues in the basin, and documents the plan of study that will be followed during the study-unit investigation.

  8. Water requirements of the petroleum refining industry

    USGS Publications Warehouse

    Otts, Louis Ethelbert

    1964-01-01

    About 3,500 million gallons of water was withdrawn daily in 1955 for use by petroleum refineries in the United States. This was about 3 percent of the estimated daily withdrawal of industrial water in the United States in 1955. An average of 468 gallons of water was required to refine a barrel of crude oil, and the median was 95 gallons of water per barrel of crude charge; withdrawals ranged from 6.5 to 3,240 gallons per barrel. Ninety-one percent of the water requirements of the petroleum refineries surveyed was for cooling. One-third of the refineries reused their cooling water from 10 to more than 50 times. Only 17 refineries used once-through cooling systems. Refineries with recirculating cooling systems circulated about twice as much cooling water but needed about 25 times less makeup; however, they consumed about 24 times more water per barrel of charge than refineries using once-through cooling systems. The average noncracking refinery used about 375 gallons of water per barrel of crude, which is less than the 471-gallon average of refineries with cracking facilities. Refineries are composed of various processing units, and the water requirements of such units varied ; median makeup needs ranged from about 125 gallons per barrel for polymerization and alkylation units to 15.5 gallons per barrel for distillation units. Refinery-owned sources of water supplied 95 percent of the makeup-water requirements. Surface-water sources provided 86 percent of the makeup-water demand. Less than 1 percent of the makeup water was obtained from reprocessed municipal sewage.

  9. Airplane Ice Detector Based on a Microwave Transmission Line

    NASA Technical Reports Server (NTRS)

    Ngo, Phong; Arndt, G. Dickey; Carl, James R.

    2004-01-01

    An electronic instrument that could detect the potentially dangerous buildup of ice on an airplane wing is undergoing development. The instrument is based on a microwave transmission line configured as a capacitance probe: at selected spots, the transmission-line conductors are partly exposed to allow any ice and/or liquid water present at those spots to act as predominantly capacitive electrical loads on the transmission line. These loads change the input impedance of the transmission line, as measured at a suitable excitation frequency. Thus, it should be possible to infer the presence of ice and/or liquid water from measurements of the input impedance and/or electrical parameters related to the input impedance. The sensory transmission line is of the microstrip type and thus thin enough to be placed on an airplane wing without unduly disturbing airflow in flight. The sensory spots are small areas from which the upper layer of the microstrip has been removed to allow any liquid water or ice on the surface to reach the transmission line. The sensory spots are spaced at nominal open-circuit points, which are at intervals of a half wavelength (in the transmission line, not in air) at the excitation frequency. The excitation frequency used in the experiments has been 1 GHz, for which a half wavelength in the transmission line is .4 in. (.10 cm). The figure depicts a laboratory prototype of the instrument. The impedance-related quantities chosen for use in this version of the instrument are the magnitude and phase of the scattering parameter S11 as manifested in the in-phase (I ) and quadrature (Q) outputs of the phase detector. By careful layout of the transmission line (including the half-wavelength sensor spacing), one can ensure that the amplitude and phase of the input to the phase detector keep shifting in the same direction as ice forms on one or more of the sensor areas. Although only one transmission-line sensor strip is used in the laboratory version, in a practical application, it could be desirable to install multiple strips on different areas to detect localized icing. In that case, a multiplexer should be used to connect the various strips to the phase detector for sequential measurements. Experiments have been performed with freezing and thawing of water and of water/glycol mixtures. The experiments have shown that, whether or not glycol is present, it is possible to distinguish between liquid water and ice via the I and Q outputs; in particular, the equipment can be adjusted so that when water freezes, I decreases and Q increases. With respect to the operation of this instrument, the main effect of glycol is to increase the freezing or thawing time.

  10. Improving catchment scale water quality modelling with continuous high resolution monitoring of metals in runoff

    NASA Astrophysics Data System (ADS)

    Saari, Markus; Rossi, Pekka; Blomberg von der Geest, Kalle; Mäkinen, Ari; Postila, Heini; Marttila, Hannu

    2017-04-01

    High metal concentrations in natural waters is one of the key environmental and health problems globally. Continuous in-situ analysis of metals from runoff water is technically challenging but essential for the better understanding of processes which lead to pollutant transport. Currently, typical analytical methods for monitoring elements in liquids are off-line laboratory methods such as ICP-OES (Inductively Coupled Plasma Optical Emission Spectroscopy) and ICP-MS (ICP combined with a mass spectrometer). Disadvantage of the both techniques is time consuming sample collection, preparation, and off-line analysis at laboratory conditions. Thus use of these techniques lack possibility for real-time monitoring of element transport. We combined a novel high resolution on-line metal concentration monitoring with catchment scale physical hydrological modelling in Mustijoki river in Southern Finland in order to study dynamics of processes and form a predictive warning system for leaching of metals. A novel on-line measurement technique based on micro plasma emission spectroscopy (MPES) is tested for on-line detection of selected elements (e.g. Na, Mg, Al, K, Ca, Fe, Ni, Cu, Cd and Pb) in runoff waters. The preliminary results indicate that MPES can sufficiently detect and monitor metal concentrations from river water. Water and Soil Assessment Tool (SWAT) catchment scale model was further calibrated with high resolution metal concentration data. We show that by combining high resolution monitoring and catchment scale physical based modelling, further process studies and creation of early warning systems, for example to optimization of drinking water uptake from rivers, can be achieved.

  11. Assessment of bisphenol A released from reusable plastic, aluminium and stainless steel water bottles.

    PubMed

    Cooper, James E; Kendig, Eric L; Belcher, Scott M

    2011-10-01

    Bisphenol A (BPA) is a ubiquitous high volume industrial chemical that is an estrogen and an environmental endocrine disrupting chemical. Bisphenol A is used extensively in the production of consumer goods, polycarbonate plastics, epoxy resins and coatings used to line metallic food and beverage cans. There is great concern regarding the possible harmful effects from exposures that result from BPA leaching into foods and beverages from packaging or storage containers. The objective of this study was to independently assess whether BPA contamination of water was occurring from different types of reusable drinking bottles marketed as alternatives to BPA-containing polycarbonate plastics. Using a sensitive and quantitative BPA-specific competitive enzyme-linked immunosorbent assay we evaluated whether BPA migrated into water stored in polycarbonate or copolyester plastic bottles, and different lined or unlined metallic reusable water bottles. At room temperature the concentration of BPA migrating from polycarbonate bottles ranged from 0.2 to 0.3 mg L⁻¹. Under identical conditions BPA migration from aluminium bottles lined with epoxy-based resins was variable depending on manufacturer ranging from 0.08 to 1.9 mg L⁻¹. Boiling water significantly increased migration of BPA from the epoxy lined bottles. No detectable BPA contamination was observed in water stored in bottles made from Tritan™ copolyester plastic, uncoated stainless steel, or aluminium lined with EcoCare™. The results from this study demonstrate that when used according to manufacturers' recommendations reusable water bottles constructed from "BPA-free" alternative materials are suitable for consumption of beverages free of BPA contamination. Copyright © 2011 Elsevier Ltd. All rights reserved.

  12. Assessment of Bisphenol A Released from Reusable Plastic, Aluminium and Stainless Steel Water Bottles

    PubMed Central

    Cooper, James E.; Kendig, Eric L.; Belcher, Scott M.

    2011-01-01

    Bisphenol A(BPA) is a ubiquitous high volume industrial chemical that is an estrogen and an environmental endocrine disrupting chemical. Bisphenol A is used extensively in the production of consumer goods, polycarbonate plastics, epoxy resins, coating used to line metallic food and beverage cans, and other products.There is great concern regarding the possible harmful effects from exposures that result from BPAleaching into foods and beverages from packaging or storage containers. The objective of this study was to independently assesswhether BPA contamination of water was occurring from different types of reusable drinking bottlesmarketed as alternatives to BPA-containing polycarbonate plastics. Using a sensitive and quantitative BPA-specific competitive enzyme-linked immunosorbent assaywe evaluated whether BPA migrated into water stored inpolycarbonateor copolyester plastic bottles, and different lined or unlined metallic reusable water bottles. At room temperature the concentration of BPA migrating from polycarbonate bottles ranged from 0.2–0.3 mg/L. Under identical conditions BPA migration from aluminium bottles lined with epoxy-based resins was variable depending on manufacturer ranging from 0.08 to 1.9 mg/L.Boiling water significantly increased migration of BPA from the epoxy lined bottles. No detectable BPA contamination was observed in water stored in bottles made from Tritan™ copolyester plastic, uncoated stainless steel, or aluminium lined with EcoCare™. The results from this study demonstrate that when used according to manufactures’ recommendations reusable water bottles constructed from “BPA-free” alternative materials are suitable for consumption of beverages free of BPA contamination. PMID:21741673

  13. 5. HANCOCK AVENUE NEAR HIGH WATER MARK LOOKING SOUTH TO ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. HANCOCK AVENUE NEAR HIGH WATER MARK LOOKING SOUTH TO PENNSYLVANIA MONUMENT. NOTE LINE OF MONUMENTS AND CONTEMPORARY ADAPTATION OF GUTTER, (PAVED WITH YELLOW CAUTION MARKINGS) NOT STONE LINED. VIEW S. - Gettysburg National Military Park Tour Roads, Gettysburg, Adams County, PA

  14. Geophysical analysis of the Salmon Peak Formation near Amistad Reservoir Dam, Val Verde County, Texas, and Coahuila, Mexico, March 2006, to aid in piezometer placement

    USGS Publications Warehouse

    Stanton, Gregory P.; Kress, Wade H.; Teeple, Andrew; Greenslate, Michael L.; Clark, Allan K.

    2007-01-01

    Since 1992, numerous sinkholes have developed northwest of the Amistad Reservoir dam on the Rio Grande. Increases in the discharge of springs south of the dam, on the western side of the Rio Grande, in Coahuila, Mexico, have been documented. In 1995 the Mexico Section of the International Boundary and Water Commission (IBWC) completed a study of the western embankment (Coahuila, Mexico) of the dam that included surface geophysics, borehole geophysics, and installation of piezometers to learn more about subsurface conditions. As part of a 5-year safety inspection in 2005, technical advisors recommended that one line of similarly constructed piezometers be installed on the eastern embankment (Val Verde County, Texas) of the dam for comparison of water levels (potentiometric head) on both the western and eastern embankments of Amistad Reservoir dam. To provide technical assistance for the horizontal and vertical placement of piezometers on the eastern embankment of Amistad Reservoir dam, the U.S. Geological Survey, in cooperation with the U.S. Section of the IBWC, conducted a study along both the western and eastern embankments of Amistad Reservoir dam. The study involved an integrated approach using surface and borehole geophysical methods. In the western embankment investigation, geological and geophysical characteristics that indicate relatively large water-yielding properties of the Salmon Peak Formation were identified. The direct-current (DC) resistivity method was selected as the surface geophysical reconnaissance technique to correlate relatively large water-yielding properties of the Salmon Peak Formation, identified from analysis of borehole geophysical logs, with variations in subsurface resistivity. The dipole-dipole array and the reciprocal Schlumberger array were selected as the most applicable DC resistivity arrays. Two resistivity units were identified in both the dipole-dipole array data and the reciprocal Schlumberger array data along DC resistivity profiles on both embankments. Resistivity unit 1 generally is of relatively low resistivity, ranging from 45 to 150 ohm-meters compared with resistivity unit 2, which ranges from 120 to 345 ohm-meters (depending on the DC array type). The presence of mapped sinkholes in the reservoir north of the western embankment study area and the zone of increased water content (as indicated by zones of low neutron log count rates in nearby piezometers) leads to the conclusion that resistivity unit 1 is a preferential flow path where surface water from Amistad Reservoir is forced into the ground-water system (because of increased head from the reservoir). In the eastern embankment investigation, trends in the spatial distribution of sinkholes and the occurrence of weathered zones were identified from geologic descriptions of cores. The correlation of surface geophysical DC resistivity, historical lithologic data, and general trend of documented sinkholes along the eastern end of the eastern embankment profile were used to justify further exploration (drilling of piezometers) in the eastern expression of resistivity unit 1. The spatial location of the piezometers and the screened intervals were selected to best match the locations of the screened intervals of the western embankment piezometers. Six piezometers were installed on the eastern embankment and logged using borehole geophysical techniques. Surface DC resistivity sections superimposed on the resistivity logs for two piezometers indicate three discernible resistivity units that correlate with resistivity units 2, 1, and 2, respectively, identified in the western embankment study area. Resistivity units 1 and 2 in the DC resistivity profiles generally correspond with low and high resistivity zones, respectively, on the normal and lateral resistivity logs collected in the nearby piezometers at the time of installation.

  15. Environmental and hydrologic setting of the Ozark Plateaus study unit, Arkansas, Kansas, Missouri, and Oklahoma

    USGS Publications Warehouse

    Adamski, James C.; Petersen, James C.; Freiwald, David A.; Davis, Jerri V.

    1995-01-01

    The environmental and hydrologic setting of the Ozark Plateaus National Water-Quality Assessment (NAWQA) study unit and the factors that affect water quality are described in this report. The primary natural and cultural features that affect water- quality characteristics and the potential for future water-quality problems are described. These environmental features include climate, physio- graphy, geology, soils, population, land use, water use, and surface- and ground-water flow systems. The study-unit area is approximately 47,600 square miles and includes most of the Ozark Plateaus Province and parts of the adjacent Osage Plains and Mississippi Alluvial Plain in parts of Arkansas, Kansas, Missouri, and Oklahoma. The geology is characterized by basement igneous rocks overlain by a thick sequence of dolomites, limestones, sandstones, and shales of Paleozoic age. Land use in the study unit is predominantly pasture and forest in the southeastern part, and pasture and cropland in the northwestern part. All or part of the White, Neosho-lllinois, Osage, Gasconade, Meramec, St. Francis, and Black River Basins are within the study unit. Streams in the Boston Mountains contain the least mineralized water, and those in the Osage Plains contain the most mineralized water. The study unit contains eight hydrogeologic units including three major aquifers--the Springfield Plateau, Ozark, and St. Francois aquifers. Streams and aquifers in the study unit generally contain calcium or calcium-magnesium bicarbonate waters. Ground- and surface-water interactions are greatest in the Salem and Springfield Plateaus and least in the Boston Mountains and Osage Plains. Geology, land use, and population probably are the most important environmental factors that affect water quality.

  16. Geohydrology of Storage Unit III and a combined flow model of the Santa Barbara and foothill ground-water basins, Santa Barbara County, California

    USGS Publications Warehouse

    Freckleton, John R.; Martin, Peter; Nishikawa, Tracy

    1998-01-01

    The city of Santa Barbara pumps most of its ground water from the Santa Barbara and Foothill ground-water basins. The Santa Barbara basin is subdivided into two storage units: Storage Unit I and Storage Unit III. The Foothill basin and Storage Unit I of the Santa Barbara basin have been studied extensively and ground-water flow models have been developed for them. In this report, the geohydrology of the Santa Barbara ground- water basin is described with a special emphasis on Storage Unit III in the southwestern part of the basin. The purposes of this study were to summarize and evaluate the geohydrology of Storage Unit III and to develop an areawide model of the Santa Barbara and Foothill basins that includes the previously unmodeled Storage Unit III. Storage Unit III is in the southwestern part of the city of Santa Barbara. It is approximately 3.5 miles long and varies in width from about 2,000 feet in the southeast to 4,000 feet in the north-west. Storage Unit III is composed of the Santa Barbara Formation and overlying alluvium. The Santa Barbara Formation (the principal aquifer) consists of Pleistocene and Pliocene(?) unconsolidated marine sand, silt, and clay, and it has a maximum saturated thickness of about 160 feet. The alluvium that overlies the Santa Barbara Formation has a maximum saturated thickness of about 140 feet. The storage unit is bounded areally by faults and low-permeability deposits and is underlain by rocks of Tertiary age. The main sources of recharge to Storage Unit III are seepage from Arroyo Burro and infiltration of precipitation. Most of the recharge occurs in the northwest part of the storage unit, and ground water flows toward the southeast along the unit's long axis. Lesser amounts of recharge may occur as subsurface flow from the Hope Ranch subbasin and as upwelling from the underlying Tertiary rocks. Discharge from Storage Unit III occurs as pumpage, flow to underground drains, underflow through alluvium in the vicinity of Arroyo Burro across the Lavigia Fault, evapotranspiration, and underflow to the Pacific Ocean. The faults that bound Storage Unit III generally are considered to be effective barriers to the flow of ground water. Interbasin ground-water flow occurs where deposits of younger alluvium along stream channels cross faults. Ground-water quality in Storage Unit III deposits varies with location and depth. Upward leakage of poor-quality water from the underlying Tertiary rocks occurs in the storage unit, and such leakage can be influenced by poor well construction or by heavy localized pumping. The highest dissolved-solids concentration (4,710 milligrams per liter) in ground water resulting from this upward leakage is found in the coastal part of the storage unit. The ground-water system was modeled as two horizontal layers. In the Foothill basin and Storage Unit I the layers are separated by a confining bed. The upper layer represents the upper producing zone and the shallow zone near the coast. The lower layer represents the lower producing zone. In general, the faults in the study area were assumed to be no-flow boundaries, except for the offshore fault that forms the southeast boundary; the southeast boundary was simulated as a general-head boundary. The Storage Unit III model was combined with the preexisting Storage Unit I and Foothill basin models, using horizontal flow barriers, to form an areawide model. The areawide model was calibrated by simulating steady-state predevelopment conditions and transient conditions for 1978-92. The nonpumping steady- state simulation was used to verify that the calibrated model yielded physically reasonable results for predevelopment conditions. The calibrated areawide model calculates water levels in Storage Unit III that are within 10 feet of measured water levels at all sites of comparison. In addition, the model adequately simulates water levels in the Storage Unit I and Foothill basin areas. A total of 33,430 acre-feet of water was pum

  17. Water Quality: Water Education for Teachers. A 4-H School Enrichment Program.

    ERIC Educational Resources Information Center

    Powell, G. Morgan; Kling, Emily B.

    This looseleaf notebook is a teacher resource package that is designed for enrichment program use. It contains five units dealing with water quality: (1) The Water Cycle; (2) Our Water Supply; (3) Waste/Water Treatment; (4) Water Conservation; (5) Water Pollution. The units provide background information, experiments, stories, poems, plays, and…

  18. Chemical characteristics of ground-water discharge along the south rim of Grand Canyon in Grand Canyon National Park, Arizona, 2000-2001

    USGS Publications Warehouse

    Monroe, Stephen A.; Antweiler, Ronald C.; Hart, Robert J.; Taylor, Howard E.; Truini, Margot; Rihs, John R.; Felger, Tracey J.

    2005-01-01

    Springs flowing from the south rim of Grand Canyon are an important resource of Grand Canyon National Park, offering refuge to endemic and exotic terrestrial wildlife species and maintaining riparian areas. Population growth on the Coconino Plateau has increased the demand for additional development of ground-water resources, and such development could reduce spring discharge and affect the sustainability of riparian areas within the park. In addition, springs are an important source of drinking water for hikers and are culturally and economically important to Native Americans living in the region. Water samples were collected from May 2000 to September 2001 from 20 spring and creek sites that discharge water from the Redwall-Muav Limestone aquifer along the south rim of Grand Canyon. Sample collection sites were described and samples were analyzed for major ions, nutrients, trace elements, radioactivity, and selected isotopes, and potential sources of ground-water flow to the springs. Rock samples representing the major stratigraphic units of Grand Canyon were collected near the Bright Angel Fault and analyzed for mineralogy, strontium-87/strontium-86, and carbon-13/carbon-12. The chemical composition of water samples collected from a given spring did not vary appreciably over the course of the study. Although water at each spring had a temporally constant composition, the composition was chemically distinct from that of every other spring sampled, indicating spatial variability in the ground-water composition. Most samples had a calcium magnesium bicarbonate composition; a few had a substantial sulfate component. Concentrations of arsenic, nitrate, selenium, uranium, and gross alpha approached or exceeded U.S. Environmental Protection Agency Maximum Contaminant Levels in water discharging from some springs. Oxygen and hydrogen isotopic compositions varied little among samples, and for most sites the isotopic data plot close to the global meteoric water line or below the local meteoric water line. Isotopic enrichment indicates fractionation due to evaporation occurs at some sites. The evaporative process may occur prior to recharge or post-discharge. Flow paths are differentiated between the eastern part of the study area where strontium-87/strontium-86 values for water from springs and creeks are more radiogenic than strontium-87/strontium-86 values for water that discharges from sites farther west. Tritium and carbon isotope analyses indicate that residence time of ground-water discharge from springs and creeks ranges from less than 50 years to about 3,400 years. Water with a residence time of less than 50 years is absent at several sites. Discharge of most springs and creeks is a mixture of younger and older waters.

  19. Aerial radiometric and magnetic survey: Aztec National Topographic Map, New Mexico

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1979-01-01

    The results of analyses of the airborne gamma radiation and total magnetic field survey flown for the region identified as the Aztec National Topographic Map NJ13-10 are presented. The airborne data gathered are reduced by ground computer facilities to yield profile plots of the basic uranium, thorium and potassium equivalent gamma radiation intensities, ratios of these intensities, aircraft altitude above the earth's surface, total gamma ray and earth's magnetic field intensity, correlated as a function of geologic units. The distribution of data within each geologic unit, for all surveyed map lines and tie lines, has been calculated and is included.more » Two sets of profiled data for each line are included, with one set displaying the above-cited data. The second set includes only flight line magnetic field, temperature, pressure, altitude data plus magnetic field data as measured at a base station. A general description of the area, including descriptions of the various geologic units and the corresponding airborne data, is included also.« less

  20. Efficiency and economic benefits of skipjack pole and line (huhate) in central Moluccas, Indonesia

    NASA Astrophysics Data System (ADS)

    Siahainenia, Stevanus M.; Hiariey, Johanis; Baskoro, Mulyono S.; Waeleruny, Wellem

    2017-10-01

    Excess fishing capacity is a crucial problem in marine capture fisheries. This phenomenon needed to be investigated regarding sustainability and development of the fishery. This research was aimed at analyzing technical efficiency (TE) and computing financial aspects of the skipjack pole and line. Primary data were collected from the owners of the fishing units at the different size of gross boat tonnage (GT), while secondary data were gathered from official publications relating to this research. Data envelopment analysis (DEA) approach was applied to estimate technical efficiency whereas a selected financial analysis was utilized to calculate economic benefits of the skipjack pole and line business. The fishing units with a size of 26-30 GT provided a higher TE value, and also achieved larger economic benefit values than that of the other fishing units. The empirical results indicate that skipjack pole and line in the size of 26-30 GT is a good fishing gear for the business development in central Moluccas.

  1. Aerial radiometric and magnetic survey: Lander National Topographic Map, Wyoming

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1979-01-01

    The results of analyses of the airborne gamma radiation and total magnetic field survey flown for the region identified as the Lander National Topographic Map NK12-6 are presented. The airborne data gathered are reduced by ground computer facilities to yield profile plots of the basic uranium, thorium and potassium equivalent gamma radiation intensities, ratios of these intensities, aircraft altitude above the earth's surface, total gamma ray and earth's magnetic field intensity, correlated as a function of geologic units. The distribution of data within each geologic unit, for all surveyed map lines and tie lines, has been calculated and is included.more » Two sets of profiled data for each line are included, with one set displaying the above-cited data. The second set includes only flight line magnetic field, temperature, pressure, altitude data plus magnetic field data as measured at a base station. A general description of the area, including descriptions of the various geologic units and the corresponding airborne data, is included also.« less

  2. A new e-beam application in the pharmaceutical industry

    NASA Astrophysics Data System (ADS)

    Sadat, Theo; Malcolm, Fiona

    2005-10-01

    The paper presents a new electron beam application in the pharmaceutical industry: an in-line self-shielded atropic transfer system using electron beam for surface decontamination of products entering a pharmaceutical filling line. The unit was developed by Linac Technologies in response to the specifications of a multi-national pharmaceutical company, to solve the risk of microbial contamination entering a filling line housed inside an isolator. In order to fit the sterilization unit inside the pharmaceutical plant, a "miniature" low-energy (200 keV) electron beam accelerator and e-beam tunnel were designed, all conforming to the pharmaceutical good manufacturing practice (GMP) regulations. Process validation using biological indicators is described, with reference to the regulations governing the pharmaceutical industry. Other industrial applications of a small-sized self-shielded electron beam sterilization unit are mentioned.

  3. Laser-driven beam lines for delivering intensity modulated radiation therapy with particle beams

    PubMed Central

    Hofmann, Kerstin M; Schell, Stefan; Wilkens, Jan J

    2012-01-01

    Abstract Laser-accelerated particles are a promising option for radiation therapy of cancer by potentially combining a compact, cost-efficient treatment unit with the physical advantages of charged particle beams. To design such a treatment unit we consider different dose delivery schemes and analyze the necessary devices in the required particle beam line for each case. Furthermore, we point out that laser-driven treatment units may be ideal tools for motion adaptation during radiotherapy. Reasons for this are the potential of a flexible gantry and the time structure of the beam with high particle numbers in ultrashort bunches. One challenge that needs to be addressed is the secondary radiation produced in several beam line elements. (© 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim) PMID:22930653

  4. Ground-water hydrology of the Willamette basin, Oregon

    USGS Publications Warehouse

    Conlon, Terrence D.; Wozniak, Karl C.; Woodcock, Douglas; Herrera, Nora B.; Fisher, Bruce J.; Morgan, David S.; Lee, Karl K.; Hinkle, Stephen R.

    2005-01-01

    The Willamette Basin encompasses a drainage of 12,000 square miles and is home to approximately 70 percent of Oregon's population. Agriculture and population are concentrated in the lowland, a broad, relatively flat area between the Coast and Cascade Ranges. Annual rainfall is high, with about 80 percent of precipitation falling from October through March and less than 5 percent falling in July and August, the peak growing season. Population growth and an increase in cultivation of crops needing irrigation have produced a growing seasonal demand for water. Because many streams are administratively closed to new appropriations in summer, ground water is the most likely source for meeting future water demand. This report describes the current understanding of the regional ground-water flow system, and addresses the effects of ground-water development. This study defines seven regional hydrogeologic units in the Willamette Basin. The highly permeable High Cascade unit consists of young volcanic material found at the surface along the crest of the Cascade Range. Four sedimentary hydrogeologic units fill the lowland between the Cascade and Coast Ranges. Young, highly permeable coarse-grained sediments of the upper sedimentary unit have a limited extent in the floodplains of the major streams and in part of the Portland Basin. Extending over much of the lowland where the upper sedimentary unit does not occur, silts and clays of the Willamette silt unit act as a confining unit. The middle sedimentary unit, consisting of permeable coarse-grained material, occurs beneath the Willamette silt and upper sedimentary units and at the surface as terraces in the lowland. Beneath these units is the lower sedimentary unit, which consists of predominantly fine-grained sediments. In the northern part of the basin, lavas of the Columbia River basalt unit occur at the surface in uplands and beneath the basin-fill sedimentary units. The Columbia River basalt unit contains multiple productive water-bearing zones. A basement confining unit of older marine and volcanic rocks of low permeability underlies the basin and occurs at land surface in the Coast Range and western part of the Cascade Range. Most recharge in the basin is from infiltration of precipitation, and the spatial distribution of recharge mimics the distribution of precipitation, which increases with elevation. Basinwide annual mean recharge is estimated to be 22 inches. Rain and snowmelt easily recharge into the permeable High Cascade unit and discharge within the High Cascade area. Most recharge in the Coast Range and western part of the Cascade Range follows short flowpaths through the upper part of the low permeability material and discharges to streams within the mountains. Consequently, recharge in the Coast and Ranges is not available as lateral ground-water flow into the lowland, where most ground-water use occurs. Within the lowland, annual mean recharge is 16 inches and most recharge occurs from November to April, when rainfall is large and evapotranspiration is small. From May to October recharge is negligible because precipitation is small and evapotranspiration is large. Discharge of ground water is mainly to streams. Ground-water discharge is a relatively large component of flow in streams that drain the High Cascade unit and parts of the Portland Basin where permeable units are at the surface. In streams that do not head in the High Cascade area, streamflow is generally dominated by runoff of precipitation. Ground-water in the permeable units in the lowland discharges to the major streams where there is a good hydraulic connection between aquifers and streams. Ground-water discharge to smaller streams, which flow on the less permeable Willamette silt unit, is small and mostly from the Willamette silt unit. Most ground-water withdrawals occur within the lowland. Irrigation is the largest use of ground water, accounting for 240,000 acre feet of withdrawals, or 81 p

  5. Hydrochemical Regions of the Glacial Aquifer System, Northern United States, and Their Environmental and Water-Quality Characteristics

    USGS Publications Warehouse

    Arnold, Terri L.; Warner, Kelly L.; Groschen, George E.; Caldwell, James P.; Kalkhoff, Stephen J.

    2008-01-01

    The glacial aquifer system in the United States is a large (953,000 square miles) regional aquifer system of heterogeneous composition. As described in this report, the glacial aquifer system includes all unconsolidated geologic material above bedrock that lies on or north of the line of maximum glacial advance within the United States. Examining ground-water quality on a regional scale indicates that variations in the concentrations of major and minor ions and some trace elements most likely are the result of natural variations in the geologic and physical environment. Study of the glacial aquifer system was designed around a regional framework based on the assumption that two primary characteristics of the aquifer system can affect water quality: intrinsic susceptibility (hydraulic properties) and vulnerability (geochemical properties). The hydrochemical regions described in this report were developed to identify and explain regional spatial variations in ground-water quality in the glacial aquifer system within the hypothetical framework context. Data analyzed for this study were collected from 1991 to 2003 at 1,716 wells open to the glacial aquifer system. Cluster analysis was used to group wells with similar ground-water concentrations of calcium, chloride, fluoride, magnesium, potassium, sodium, sulfate, and bicarbonate into five unique groups. Maximum Likelihood Classification was used to make the extrapolation from clustered groups of wells, defined by points, to areas of similar water quality (hydrochemical regions) defined in a geospatial model. Spatial data that represented average annual precipitation, average annual temperature, land use, land-surface slope, vertical soil permeability, average soil clay content, texture of surficial deposits, type of surficial deposit, and potential for ground-water recharge were used in the Maximum Likelihood Classification to classify the areas so the characteristics of the hydrochemical regions would resemble the characteristics of the clusters. The result of the Maximum Likelihood Classification is a map showing five hydrochemical regions of the glacial aquifer system. Statistical analysis of ion concentrations (calcium, chloride, fluoride, magnesium, sodium, potassium, sulfate, and bicarbonate) in samples collected from wells completed in the glacial aquifer system illustrates that variations in water quality can be explained, in part, by related environmental characteristics that control the movement of ground water through the aquifer system. A comparison of median concentrations of chemical constituents in ground water among the five hydrochemical regions indicates that ground water in the Midwestern Agricultural Region, the Urban-Influenced Region, and the Western Agriculture and Grassland Region has the highest concentrations of major and minor ions, whereas ground water in the Northern and Great Lakes Forested Region and the Mountain and Coastal Forested Region has the lowest concentrations of these ions. Median concentrations of barium, arsenic, lithium, boron, strontium, and nitrite plus nitrate as nitrogen also are significantly different among the hydrochemical regions.

  6. Design of Reconnaissance Helicopter Electromagnetic and Magnetic Geophysical Surveys of the North Platte River and Lodgepole Creek, Nebraska

    NASA Astrophysics Data System (ADS)

    Smith, B. D.; Cannia, J. C.; Abraham, J. D.

    2009-12-01

    An innovative flight line layout using widely separated lines was used for frequency domain helicopter electromagnetic (HEM) surveys in 2008 and 2009 in the Panhandle of western Nebraska. The HEM survey design was developed as part of a joint hydrologic study by the North Platte Natural Resource District, South Platte Natural Resource District, UNL-Conservation and Survey Division, and U.S. Geological Survey to improve the understanding of relationships between surface water and groundwater systems critical to developing groundwater flow models used in water resources management programs. Use of HEM methods for hydrologic mapping had been demonstrated by HEM surveys conducted in 2007 of sites in the glaciated Platte River Basin in eastern Nebraska. These surveys covered township-scale areas with flight lines laid out in blocks where the lines were spaced about 270m apart. The HEM successfully mapped the complex 3D geometry of shallow sand and gravel aquifers through and within conductive till to a depth of about 40m in a total area of about 680 km2 (263 mi2). Current groundwater flow models in western Nebraska include the Cooperative Hydrologic Study (COHYST), run by a consortium of state agencies, which is tasked to develop scientifically supportable hydrologic databases, analyses, and models, and the North Platte River Valley Optimization Model (NPRVOM). The COHYST study area, about 75,000 km2 (29,000 mi2), includes the Platte River Basin from the Nebraska - Wyoming border to Lincoln. Considering the large area of the groundwater models, the USGS decided in collaboration with the NRD to use a more reconnaissance-style layout for the 2008 HEM survey which encompassed about 21,000 km2 (8,000 mi2). A reconnaissance-type HEM survey is made possible due to technical capabilities of applicable HEM systems and due to the level of hydrogeologic information available in the NRD. The particular capabilities of the HEM system are careful calibration, low drift, low noise, and leveling. The widely spaced lines do not provide as much opportunity for self-checking by line-to-line correlation as closely spaced lines. The final project design in 2008 consisted of flight lines paralleling the major drainages and lines perpendicular to the drainages spaced about 10 km (6 mi) apart. Layout of lines following the drainages is similar to the design of previous HEM surveys of levees. Although the general geologic features are known to be broad (sandstone channels and bedrock topography) from wells spaced about 2.5 km (1.5 mi), two “standard blocks” were flown with 270 m line spacing in critical areas to both better resolve of electrical signatures and to provide greater detail than the reconnaissance survey. The processed data from the two detailed survey blocks confirmed hypothesized electrical signatures of major hydrostratigraphic units in the area. Interpretation of data from the widely spaced lines, lines along the rivers, and the detail blocks fit well with the known hydrogeology.

  7. Transformation of plum plants with a cytosolic ascorbate peroxidase transgene leads to enhanced water stress tolerance

    PubMed Central

    Diaz-Vivancos, Pedro; Faize, Lydia; Nicolás, Emilio; Clemente-Moreno, Maria José; Bru-Martinez, Roque; Burgos, Lorenzo; Hernández, José Antonio

    2016-01-01

    Background and Aims Water deficit is the most serious environmental factor limiting agricultural production. In this work, the tolerance to water stress (WS) of transgenic plum lines harbouring transgenes encoding cytosolic antioxidant enzymes was studied, with the aim of achieving the durable resistance of commercial plum trees. Methods The acclimatization process was successful for two transgenic lines: line C3-1, co-expressing superoxide dismutase (two copies) and ascorbate peroxidase (one copy) transgenes simultaneously; and line J8-1, harbouring four copies of the cytosolic ascorbate peroxidase gene (cytapx). Plant water relations, chlorophyll fluorescence and the levels of antioxidant enzymes were analysed in both lines submitted to moderate (7 d) and severe (15 d) WS conditions. Additionally, in line J8-1, showing the best response in terms of stress tolerance, a proteomic analysis and determination of the relative gene expression of two stress-responsive genes were carried out. Key Results Line J8-1 exhibited an enhanced stress tolerance that correlated with better photosynthetic performance and a tighter control of water-use efficiency. Furthermore, this WS tolerance also correlated with a higher enzymatic antioxidant capacity than wild-type (WT) and line C3-1 plum plants. On the other hand, line C3-1 displayed an intermediate phenotype between WT plants and line J8-1 in terms of WS tolerance. Under severe WS, the tolerance displayed by J8-1 plants could be due to an enhanced capacity to cope with drought-induced oxidative stress. Moreover, proteomic analysis revealed differences between WT and J8-1 plants, mainly in terms of the abundance of proteins related to carbohydrate metabolism, photosynthesis, antioxidant defences and protein fate. Conclusions The transformation of plum plants with cytapx has a profound effect at the physiological, biochemical, proteomic and genetic levels, enhancing WS tolerance. Although further experiments under field conditions will be required, it is proposed that J8-1 plants would be an interesting Prunus rootstock for coping with climate change. PMID:27059431

  8. Characterizing subsurface water flow to artificial drain lines using fiber-optic distributed temperature sensing

    NASA Astrophysics Data System (ADS)

    Shults, D.; Brooks, E. S.; Heinse, R.; Keller, C. K.

    2017-12-01

    Over the last several years growers have experienced increasingly wet spring conditions in the Palouse Region located in North Idaho, Eastern Washington and Eastern Oregon. As a result more artificial drain lines are being installed so growers can access their fields earlier in the growing season. Additionally there has been increasing adoption of no-tillage practices among growers in order minimize erosion and runoff in the region. There is a growing body of evidence that suggests long-term no-tillage may lead to the establishment of large macropore networks through increased earthworm activity and the preservation of root channels. These macropore networks, in conjunctions with the presence of artificial drains lines, may create connected preferential flow paths from agricultural fields to receiving streams. This connectivity of flow paths from agricultural fields to receiving water bodies may increase the loading of nutrients and agricultural chemicals as some flow paths may largely bypass soil matrix interaction where materials can be sequestered. Our primary objective for this study was to characterize subsurface flow to two artificial drain lines, one under conventional tillage and the other under no-tillage, using distributed temperature sensing (DTS) technology. During the study (November 2016-April 2017) the near surface soil-water temperature was consistently colder than that of deeper depths. Temperature was thus used as a tracer as snow melt and soil-water moved from the near surface to the drain lines during snowmelt and precipitation events. The spatial and temporal variability of the temperature along the artificial drain line under no-tillage practices was found to be greater than that of the conventional tilled field. It is hypothesized that preferential flow paths are responsible for the increased variability of temperature seen in the drain line under long term no-till management. The temperature along the conventional till drain line showed a dampened response to snow melt and precipitation events during the winter indicating matrix flow was the predominate flow mechanism. In addition to temperature traces, water chemistry (electrical conductivity, pH and nitrate) and discharge measurements were collected at the outlet of each drain line as well as at access ports along the drain lines.

  9. Transformation of plum plants with a cytosolic ascorbate peroxidase transgene leads to enhanced water stress tolerance.

    PubMed

    Diaz-Vivancos, Pedro; Faize, Lydia; Nicolás, Emilio; Clemente-Moreno, Maria José; Bru-Martinez, Roque; Burgos, Lorenzo; Hernández, José Antonio

    2016-06-01

    Water deficit is the most serious environmental factor limiting agricultural production. In this work, the tolerance to water stress (WS) of transgenic plum lines harbouring transgenes encoding cytosolic antioxidant enzymes was studied, with the aim of achieving the durable resistance of commercial plum trees. The acclimatization process was successful for two transgenic lines: line C3-1, co-expressing superoxide dismutase (two copies) and ascorbate peroxidase (one copy) transgenes simultaneously; and line J8-1, harbouring four copies of the cytosolic ascorbate peroxidase gene (cytapx). Plant water relations, chlorophyll fluorescence and the levels of antioxidant enzymes were analysed in both lines submitted to moderate (7 d) and severe (15 d) WS conditions. Additionally, in line J8-1, showing the best response in terms of stress tolerance, a proteomic analysis and determination of the relative gene expression of two stress-responsive genes were carried out. Line J8-1 exhibited an enhanced stress tolerance that correlated with better photosynthetic performance and a tighter control of water-use efficiency. Furthermore, this WS tolerance also correlated with a higher enzymatic antioxidant capacity than wild-type (WT) and line C3-1 plum plants. On the other hand, line C3-1 displayed an intermediate phenotype between WT plants and line J8-1 in terms of WS tolerance. Under severe WS, the tolerance displayed by J8-1 plants could be due to an enhanced capacity to cope with drought-induced oxidative stress. Moreover, proteomic analysis revealed differences between WT and J8-1 plants, mainly in terms of the abundance of proteins related to carbohydrate metabolism, photosynthesis, antioxidant defences and protein fate. The transformation of plum plants with cytapx has a profound effect at the physiological, biochemical, proteomic and genetic levels, enhancing WS tolerance. Although further experiments under field conditions will be required, it is proposed that J8-1 plants would be an interesting Prunus rootstock for coping with climate change. © The Author 2016. Published by Oxford University Press on behalf of the Annals of Botany Company. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Experimental Line List of Water Vapor Absorption Lines in the Spectral Ranges 1850 - 2280 CM-1 and 2390-4000 CM-1

    NASA Astrophysics Data System (ADS)

    Loos, Joep; Birk, Manfred; Wagner, Georg

    2017-06-01

    A new experimental line parameter list of water vapor absorption lines in the spectral ranges 1850 - 2280 cm-1 and 2390 - 4000 cm-1 is presented. The line list is based on the analysis of several transmittance spectra measured using a Bruker IFS 125 HR high resolution Fourier transform spectrometer. A total of 54 measurements of pure water and water/air-mixtures at 296 K as well as water/air-mixtures at high and low temperatures were performed. A multispectrum fitting approach was used applying a quadratic speed-dependent hard collision line shape model in the Hartmann-Tran implementation extended to account for line mixing in the Rosenkranz approximation in order to retrieve line positions, intensities, self- and air-broadening parameters, their speed-dependence, self- and air-shifts as well as line mixing and in some cases collisional narrowing parameters. Additionally, temperature dependence parameters for widths, shifts and in a few cases line mixing were retrieved. For every parameter an extensive error estimation calculation was performed identifying and specifying systematic error sources. The resulting parameters are compared to the databases HITRAN12 as well as experimental values. For intensities, a detailed comparison to results of recent ab initio calculations performed at University College London was done showing an agreement within 2 % for a majority of the data. However, for some bands there are systematic deviations attributed to ab initio calculation errors. .H. Ngo et al. JQSRT 129, 89-100 (2013) doi:10.1016/j.jqsrt.2013.05.034; JQSRT 134, 105 (2014) doi:10.1016/j.jqsrt.2013.10.016. H. Tran et al. JQSRT 129, 199-203 (2013) doi:10.1016/j.jqsrt.2013.06.015; JQSRT 134, 104 (2014) doi:10.1016/j.jqsrt.2013.10.015. L.S. Rothman et al. JQSRT 130, 4-50 (2013) doi:10.1016/j.jqsrt.2013.07.002. N. Jacquinet-Husson et al. JMS 112, 2395-2445 (2016) doi:10.1016/j.jms.2016.06.007.

  11. DIRECT IMAGING OF THE WATER SNOW LINE AT THE TIME OF PLANET FORMATION USING TWO ALMA CONTINUUM BANDS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Banzatti, A.; Pontoppidan, K. M.; Pinilla, P.

    2015-12-10

    Molecular snow lines in protoplanetary disks have been studied theoretically for decades because of their importance in shaping planetary architectures and compositions. The water snow line lies in the planet formation region at ≲10 AU, and so far its location has been estimated only indirectly from spatially unresolved spectroscopy. This work presents a proof-of-concept method to directly image the water snow line in protoplanetary disks through its physical and chemical imprint on the local dust properties. We adopt a physical disk model that includes dust coagulation, fragmentation, drift, and a change in fragmentation velocities of a factor of 10 betweenmore » dry silicates and icy grains as found by laboratory work. We find that the presence of a water snow line leads to a sharp discontinuity in the radial profile of the dust emission spectral index α{sub mm} due to replenishment of small grains through fragmentation. We use the ALMA simulator to demonstrate that this effect can be observed in protoplanetary disks using spatially resolved ALMA images in two continuum bands. We explore the model dependence on the disk viscosity and find that the spectral index reveals the water snow line for a wide range of conditions, with opposite trends when the emission is optically thin rather than thick. If the disk viscosity is low (α{sub visc} < 10{sup −3}), the snow line produces a ringlike structure with a minimum at α{sub mm} ∼ 2 in the optically thick regime, possibly similar to what has been measured with ALMA in the innermost region of the HL Tau disk.« less

  12. Extracting environmental information from lake water isotopes - a novel approac

    NASA Astrophysics Data System (ADS)

    Kopec, B. G.; Feng, X.; Lauder, A. M.; Virginia, R. A.; Posmentier, E. S.

    2014-12-01

    It is well known that hydrogen (δD) and oxygen (δ18O) isotopic composition in precipitation defines a meteoric water line with a slope close to 8 and an intercept of 10, and that evaporation causes water to deviate from the line, acquiring a d-excess value different from 10. It has also been observed that a group of lakes subject to significant evaporation often define a line, which we refer to as the lake line, with a slope lower than 8. While there has been much discussion about the slope of lake lines and its dependence on relative humidity, little attention has been given to the scatter around these lines. We show that this seemingly random scatter contains systematic environmental information. Water in over 20 lakes around Kangerlussuaq, Greenland, was collected in the summers of 2009 to 2013, and the δD and δ18O values were determined. Each year's isotopic data were used to find: 1) the slope of the lake line; 2) the displacement of each lake parallel to the lake line, which we refer to as the "enrichment"; and 3) the distance between a given lake and the lake line, which we call the "deviance". The enrichment and deviance are the values of the principal components, PC1 and PC2, respectively, of the set of δD and δ18O coordinates. When comparing the climate and environmental variables, we observed the following. A) The lake line slope varies from 4.12 to 4.63 among the 5 years. B) The enrichment is, in some years, significantly correlated with lake size and longitude (which increases along the moisture and temperature gradient). C) The deviance is significantly correlated with both lake size and longitude every year. A simple water and isotopic mass balance model suggests that the enrichment is largely controlled by the lake to basin area ratio, while the deviance is controlled predominantly by the humidity and isotopic ratios of air above the lake. The latter variables systematically change from east to west (glacial margin to coast), so longitude is a relevant explanatory variable. In addition, it appears the interannual variations of the lake line slope are controlled by the regional water balance, including precipitation, evaporation and humidity. Interestingly, the lake slope correlates quite well with the NAO index, which, according to our previous work, significantly influences the regional hydrological balance.

  13. 33 CFR 328.5 - Changes in limits of waters of the United States.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... OF THE ARMY, DEPARTMENT OF DEFENSE DEFINITION OF WATERS OF THE UNITED STATES § 328.5 Changes in... drainage may remove an area from waters of the United States. Man-made changes may affect the limits of...

  14. Development of Water Quality Modeling in the United States

    EPA Science Inventory

    This presentation describes historical trends in water quality model development in the United States, reviews current efforts, and projects promising future directions. Water quality modeling has a relatively long history in the United States. While its origins lie in the work...

  15. Galle Crater

    NASA Technical Reports Server (NTRS)

    2002-01-01

    (Released 19 June 2002) The Science This image is of part of Galle Crater, located at 51.9S, 29.5W. This image was taken far enough south and late enough into the southern hemisphere fall to catch observe water ice clouds partially obscuring the surface. The most striking aspect of the surface is the dissected layered unit to the left in the image. Other areas also appear to have layering, but they are either more obscured by clouds or are less well defined on the surface. The layers appear to be mostly flat lying and layer boundaries appear as topographic lines would on a map, but there are a few areas where it appears that these layers have been deformed to some level. Other areas of the image contain rugged, mountainous terrain as well as a separate pitted terrain where the surface appears to be a separate unit from the mountains and the layered terrain. The Story Galle Crater is officially named after a German astronomer who, in 1846, was the first to observe the planet Neptune. It is better known, however, as the 'Happy Face Crater.' The image above focuses on too small an area of the crater to see its beguiling grin, but you can catch the rocky line of a 'half-smile' in the context image to the right (to the left of the red box). While water ice clouds make some of the surface harder to see, nothing detracts from the fabulous layering at the center left-hand edge of the image. If you click on the above image, the scalloped layers almost look as if a giant knife has swirled through a landscape of cake frosting. These layers, the rugged, mountains near them, and pits on the surface (upper to middle section of the image on the right-hand side) all create varying textures on the crater floor. With such different features in the same place, geologists have a lot to study to figure out what has happened in the crater since it formed.

  16. Evaluation of the surface-water sampling design in the Western Lake Michigan Drainages in relation to environmental factors affecting water quality at base flow

    USGS Publications Warehouse

    Robertson, Dale M.

    1998-01-01

    The variability in water quality throughout the WMIC Study Unit during base-flow conditions could be described very well by subdividing the area into Relatively Homogeneous Units and sampling a few streams with drainage basins completely within these homogeneous units. This subdivision and sampling scheme enabled the differences in water quality to be directly related to the differences in the environmental characteristics that exist throughout the Study Unit.

  17. 36 CFR 14.70 - Statutory authority.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... electrical plants, poles, and lines for the generation and distribution of electrical power, and for telephone and telegraph purposes, and for pipe lines, canals, ditches, water plants, and other purposes to the extent of the ground occupied by such canals, ditches, water plants, or other works permitted...

  18. 36 CFR 14.70 - Statutory authority.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... electrical plants, poles, and lines for the generation and distribution of electrical power, and for telephone and telegraph purposes, and for pipe lines, canals, ditches, water plants, and other purposes to the extent of the ground occupied by such canals, ditches, water plants, or other works permitted...

  19. 18 CFR 2.2 - Transmission lines.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Transmission lines. 2.2 Section 2.2 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY GENERAL RULES GENERAL POLICY AND INTERPRETATIONS Statements of General Policy and Interpretations...

  20. 18 CFR 2.2 - Transmission lines.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 18 Conservation of Power and Water Resources 1 2012-04-01 2012-04-01 false Transmission lines. 2.2 Section 2.2 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY GENERAL RULES GENERAL POLICY AND INTERPRETATIONS Statements of General Policy and Interpretations...

  1. 18 CFR 2.2 - Transmission lines.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 18 Conservation of Power and Water Resources 1 2013-04-01 2013-04-01 false Transmission lines. 2.2 Section 2.2 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY GENERAL RULES GENERAL POLICY AND INTERPRETATIONS Statements of General Policy and Interpretations...

  2. 18 CFR 2.2 - Transmission lines.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Transmission lines. 2.2 Section 2.2 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY GENERAL RULES GENERAL POLICY AND INTERPRETATIONS Statements of General Policy and Interpretations...

  3. 22 CFR 1101.2 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Relations INTERNATIONAL BOUNDARY AND WATER COMMISSION, UNITED STATES AND MEXICO, UNITED STATES SECTION... and Mexico. (d) Commissioner means head of the United States Section, International Boundary and Water Commission, United States and Mexico. (e) Individual means a citizen of the United States or an alien...

  4. 22 CFR 1103.170 - Compliance procedures.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Foreign Relations INTERNATIONAL BOUNDARY AND WATER COMMISSION, UNITED STATES AND MEXICO, UNITED STATES... INTERNATIONAL BOUNDARY AND WATER COMMISSION, UNITED STATES AND MEXICO, UNITED STATES SECTION § 1103.170... Mexico, United States Section, The Commons, Building C, Suite 310, 4171 North Mesa, El Paso, Texas 79902...

  5. 22 CFR 1101.2 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Relations INTERNATIONAL BOUNDARY AND WATER COMMISSION, UNITED STATES AND MEXICO, UNITED STATES SECTION... and Mexico. (d) Commissioner means head of the United States Section, International Boundary and Water Commission, United States and Mexico. (e) Individual means a citizen of the United States or an alien...

  6. 22 CFR 1101.2 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Relations INTERNATIONAL BOUNDARY AND WATER COMMISSION, UNITED STATES AND MEXICO, UNITED STATES SECTION... and Mexico. (d) Commissioner means head of the United States Section, International Boundary and Water Commission, United States and Mexico. (e) Individual means a citizen of the United States or an alien...

  7. 22 CFR 1101.2 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Relations INTERNATIONAL BOUNDARY AND WATER COMMISSION, UNITED STATES AND MEXICO, UNITED STATES SECTION... and Mexico. (d) Commissioner means head of the United States Section, International Boundary and Water Commission, United States and Mexico. (e) Individual means a citizen of the United States or an alien...

  8. Remote sensing of hydrologic variables in boreal areas, phase 1

    NASA Technical Reports Server (NTRS)

    Peck, Eugene L.; Carroll, Thomas R.

    1994-01-01

    The major effort by HYD-6 members has been to develop a network of flight lines to provide the maximum amount of information on the temporal and spatial variation in soil moisture for the Boreal Ecosystem Atmosphere Study (BOREAS) study areas. Field visits to the southern study area (SSA) were conducted during May 1993 to obtain first hand information on the flight lines that had been previously selected for BOREAS snow studies. In September 1993 airborne gamma radiation surveys were conducted over the SSA, the northern study area (NSA), and for five flight lines along the transect between the two study areas. In situ measurements of soil moisture and water content of the moss/humus layer were obtained for calibration of selected gamma radiation flights lines in the SSA and for two of the transit lines. The flight lines for which soil moisture will be measured during the three IFC's during the summer of 1994 is a subset of the total flight lines that have been flown for the snow surveys. During the WFC in February 1994, airborne gamma radiation surveys were flown over all of the flight lines. Members of HYD-4 collected in-situ measurements (soil moisture, water content of the moss/humus layer, and water equivalent of the snow cover).

  9. Water Supply. Fire Service Certification Series. Unit FSCS-FF-9-80.

    ERIC Educational Resources Information Center

    Pribyl, Paul F.

    This training unit on water supply is part of a 17-unit course package written to aid instructors in the development, teaching, and evaluation of fire fighters in the Wisconsin Fire Service Certification Series. The purpose stated for the 4-hour unit is to assist the firefighter in the proper use of water supplies and the understanding of the…

  10. Assessment of region, farming system, irrigation source and sampling time as food safety risk factors for tomatoes.

    PubMed

    Pagadala, Sivaranjani; Marine, Sasha C; Micallef, Shirley A; Wang, Fei; Pahl, Donna M; Melendez, Meredith V; Kline, Wesley L; Oni, Ruth A; Walsh, Christopher S; Everts, Kathryne L; Buchanan, Robert L

    2015-03-02

    In the mid-Atlantic region of the United States, small- and medium-sized farmers use varied farm management methods and water sources to produce tomatoes. It is unclear whether these practices affect the food safety risk for tomatoes. This study was conducted to determine the prevalence, and assess risk factors for Salmonella enterica, Shiga toxin-producing Escherichia coli (STEC) and bacterial indicators in pre-harvest tomatoes and their production areas. A total of 24 organic and conventional, small- to medium-sized farms were sampled for six weeks in Maryland (MD), Delaware (DE) and New Jersey (NJ) between July and September 2012, and analyzed for indicator bacteria, Salmonella and STEC. A total of 422 samples--tomato fruit, irrigation water, compost, field soil and pond sediment samples--were collected, 259 of which were tomato samples. A low level of Salmonella-specific invA and Shiga toxin genes (stx1 or stx2) were detected, but no Salmonella or STEC isolates were recovered. Of the 422 samples analyzed, 9.5% were positive for generic E. coli, found in 5.4% (n=259) of tomato fruits, 22.5% (n=102) of irrigation water, 8.9% (n=45) of soil, 3/9 of pond sediment and 0/7 of compost samples. For tomato fruit, farming system (organic versus conventional) was not a significant factor for levels of indicator bacteria. However, the total number of organic tomato samples positive for generic E. coli (1.6%; 2/129) was significantly lower than for conventional tomatoes (6.9% (9/130); (χ(2) (1)=4.60, p=0.032)). Region was a significant factor for levels of Total Coliforms (TC) (p=0.046), although differences were marginal, with western MD having the highest TC counts (2.6 log CFU/g) and NJ having the lowest (2.0 log CFU/g). Tomatoes touching the ground or plastic mulch harbored significantly higher levels of TC compared to vine tomatoes, signaling a potential risk factor. Source of irrigation water was a significant factor for all indicator bacteria (p<0.0001), and groundwater had lower bacterial levels than surface water. End of line surface water samples were not significantly different from source water samples, but end of line groundwater samples had significantly higher bacterial counts than source (p<0.0001), suggesting that Good Agricultural Practices that focus on irrigation line maintenance might be beneficial. In general, local effects other than cropping practices, including topography, land use and adjacent industries, might be important factors contributing to microbiological inputs on small- and medium-sized farms in the mid-Atlantic region. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Evaluation of mycological contamination of dental unit waterlines.

    PubMed

    Szymańska, Jolanta

    2005-01-01

    The quality of dental unit water is of great importance since patients and dental staff are regularly exposed to water from aerosols generated during work. The main purpose of this investigation was mycological evaluation of dental unit waterlines (DUWL). The author determined the number and species of fungi present in the water from a unit reservoir which is the source of water for a dental unit, in the water flowing from a high-speed handpiece of a unit, and in the swab sample collected from the wall of a waterline connecting a unit reservoir and dental handpieces. The following mould fungi were identified: Aspergillus amstelodami, Aspergillus fumigatus, Aspergillus spp. from Aspergillus glaucus group, Aspergillus repens, Citromyces spp., Geotrichum candidum, Penicillium aspergilliforme, Penicillium pusillum, Penicillium turolense, Sclerotium sclerotiorum; yeast-like fungi: Candida albicans, Candida curvata and other yeasts. Some of them, in certain circumstances, especially in people with immunological disorders, may be a cause of opportunistic infections. Thus, it is necessary that the DUWL should be submitted to a decontamination protocol and to routine microbial monitoring to guarantee an appropriate quality of water used in dental treatment.

  12. Catalyst cartridge for carbon dioxide reduction unit

    NASA Technical Reports Server (NTRS)

    Holmes, R. F. (Inventor)

    1973-01-01

    A catalyst cartridge, for use in a carbon dioxide reducing apparatus in a life support system for space vehicles, is described. The catalyst cartridge includes an inner perforated metal wall, an outer perforated wall space outwardly from the inner wall, a base plate closing one end of the cartridge, and a cover plate closing the other end of the cartridge. The cover plate has a central aperture through which a supply line with a heater feeds a gaseous reaction mixture comprising hydrogen and carbon dioxide at a temperature from about 1000 to about 1400 F. The outer surfaces of the internal wall and the inner surfaces of the outer wall are lined with a ceramic fiber batting material of sufficient thickness to prevent carbon formed in the reaction from passing through it. The portion of the surfaces of the base and cover plates defined within the inner and outer walls are also lined with ceramic batting. The heated reaction mixture passes outwardly through the inner perforated wall and ceramic batting and over the catalyst. The solid carbon product formes is retained within the enclosure containing the catalyst. The solid carbon product formed is retained within the enclosure containing the catalyst. The water vapor and unreacted carbon dioxide and any intermediate products pass through the perforations of the outer wall.

  13. Performance Evaluation of Satellite Communication Systems Operating in the Q/V/W Bands

    DTIC Science & Technology

    2013-06-30

    cloud liquid water content (blue line = original MODIS data, red line = underlying Gaussian process) and of rainfall ( NIMROD rain rate data) .. 3-22...correlation of rainfall as obtained from an extensive set of rain field collected by the NIMROD weather radar network [Luini and Capsoni, 2012] has been...underlying Gaussian process) Rain ( NIMROD data) Figure 3-21. Decorrelation with distance of the cloud liquid water content (blue line = original

  14. Temperature sensitivity of differential absorption lidar measurements of water vapor in the 720-nm region

    NASA Technical Reports Server (NTRS)

    Browell, Edward V.; Ismail, Syed; Grossmann, Benoist E.

    1991-01-01

    Recently measured properties of water vapor (H2O) absorption lines have been used in calculations to evalute the temperature sensitivity of differential absorption lidar (Dial) H2O measurements. This paper estimates the temperature sensitivity of H2O lines in the 717-733-nm region for both H2O mixing ratio and number density measurements, and discusses the influence of the H2O line ground state energies E-double-prime, the H2O absorption linewidths, the linewidth temperature dependence parameter, and the atmospheric temperature and pressure variations with altitude and location on the temperature sensitivity calculations. Line parameters and temperature sensitivity calculations for 67 H2O lines in the 720-nm band are given which can be directly used in field experiments. Water vapor lines with E-double-prime values in the 100-300/cm range were found to be optimum for Dial measurements of H2O number densities, while E-double-prime values in the 250-500/cm range were found to be optimum for H2O mixing ratio measurements.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Napier, Bruce A.; Fellows, Robert J.; Krupka, Kenneth M.

    This report describes work performed for the U.S. Nuclear Regulatory Commission’s project Assessment of Food Chain Pathway Parameters in Biosphere Models, which was established to assess and evaluate a number of key parameters used in the food-chain models used in performance assessments of radioactive waste disposal facilities. Section 2 of this report summarizes characteristics of samples of soils and groundwater from three geographical regions of the United States, the Southeast, Northwest, and Southwest, and analyses performed to characterize their physical and chemical properties. Because the uptake and behavior of radionuclides in plant roots, plant leaves, and animal products depends onmore » the chemistry of the water and soil coming in contact with plants and animals, water and soil samples collected from these regions of the United States were used in experiments at Pacific Northwest National Laboratory to determine radionuclide soil-to-plant concentration ratios. Crops and forage used in the experiments were grown in the soils, and long-lived radionuclides introduced into the groundwater provide the contaminated water used to water the grown plants. The radionuclides evaluated include 99Tc, 238Pu, and 241Am. Plant varieties include alfalfa, corn, onion, and potato. The radionuclide uptake results from this research study show how regional variations in water quality and soil chemistry affect radionuclide uptake. Section 3 summarizes the procedures and results of the uptake experiments, and relates the soil-to-plant uptake factors derived. In Section 4, the results found in this study are compared with similar values found in the biosphere modeling literature; the study’s results are generally in line with current literature, but soil- and plant-specific differences are noticeable. This food-chain pathway data may be used by the NRC staff to assess dose to persons in the reference biosphere (e.g., persons who live and work in an area potentially affected by radionuclide releases) of waste disposal facilities and decommissioning sites.« less

  16. Remote sensing of the boundary layer over the oceans. [by IRIS measurements

    NASA Technical Reports Server (NTRS)

    Prabhakara, C.; Dalu, G.; Nath, N. R.; Lo, R.

    1978-01-01

    The paper explores the possibility of remotely sensing the boundary layer structure over the oceans by means of the Nimbus 4 IR Interferometric Spectrometer (IRIS) measurements in the water vapor bands. It is found from theoretical considerations that the moderately strong spectral lines in the 9-micron water vapor window region contain useful information about the lowest layers in the atmosphere. The difference between the observed line strength and the theoretically predicted line strength provides information about the departure in the atmospheric temperature and water vapor profiles from standard conditions. The observations of METEOR oceanographic expedition over the North and South Atlantic, and the Indian Ocean expedition make it possible to model the inversion conditions. It is concluded that significant characteristics of the temperature and water vapor profiles in the boundary layer of the atmosphere can be remotely sensed using the water vapor spectral measurements over the oceans.

  17. Stratigraphic and structural controls on groundwater flow in an outcropping fossil fan delta: the case of Sant Llorenç del Munt range (NE Spain)

    NASA Astrophysics Data System (ADS)

    Anglés, Marc; Folch, Albert; Oms, Oriol; Maestro, Eudald; Mas-Pla, Josep

    2017-12-01

    Hydrogeological models of mountain regions present the opportunity to understand the role of geological factors on groundwater resources. The effects of sedimentary facies and fracture distribution on groundwater flow and resource exploitation are studied in the ancient fan delta of Sant Llorenç de Munt (central Catalonia, Spain) by integrating geological field observations (using sequence stratigraphy methods) and hydrogeological data (pumping tests, hydrochemistry and environmental isotopes). A comprehensive analysis of data portrays the massif as a single unit, constituted by different compartments determined by specific layers and sets of fractures. Two distinct flow systems—local and regional—are identified based on pumping test analysis as well as hydrochemical and isotopic data. Drawdown curves derived from pumping tests indicate that the behavior of the saturated layers, whose main porosity is given by the fracture network, corresponds to a confined aquifer. Pumping tests also reflect a double porosity within the system and the occurrence of impervious boundaries that support a compartmentalized model for the whole aquifer system. Hydrochemical data and associated spatial evolution show the result of water-rock interaction along the flow lines. Concentration of magnesium, derived from dolomite dissolution, is a tracer of the flow-path along distinct stratigraphic units. Water stable isotopes indicate that evaporation (near a 5% loss) occurs in a thick unsaturated zone within the massif before infiltration reaches the water table. The hydrogeological analysis of this outcropping system provides a methodology for the conceptualization of groundwater flow in similar buried systems where logging and hydrogeological information are scarce.

  18. 75 FR 7522 - United States Section; Notice of Availability of the Final Environmental Impact Statement, Flood...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-19

    ... Final EIS: Biological resources, cultural resources, water resources, land use, socioeconomic resources... INTERNATIONAL BOUNDARY AND WATER COMMISSION, UNITED STATES AND MEXICO United States Section..., International Boundary and Water Commission (USIBWC). ACTION: Notice of Availability of Final Environmental...

  19. Experimental Evidence of Low Density Liquid Water under Decompression

    NASA Astrophysics Data System (ADS)

    Shen, G.; Lin, C.; Sinogeikin, S. V.; Smith, J.

    2017-12-01

    Water is not only the most important substance for life, but also plays important roles in liquid science for its anomalous properties. It has been widely accepted that water's anomalies are not a result of simple thermal fluctuation, but are connected to the formation of various structural aggregates in the hydrogen bonding network. Among several proposed scenarios, one model of fluctuations between two different liquids has gradually gained traction. These two liquids are referred to as a low-density liquid (LDL) and a high-density liquid (HDL) with a coexistence line in the deeply supercooled regime at elevated pressure. The LDL-HDL transition ends with decreasing pressure at a liquid-liquid critical point (LLCP) with its Widom line extending to low pressures. Above the Widom line lies mostly HDL which is favored by entropy, while LDL, mostly lying below the Widom line, is favored by enthalpy in the tetrahedral hydrogen bonding network. The origin of water's anomalies can then be explained by the increase in structural fluctuations, as water is cooled down to deeply supercooled temperatures approaching the Widom line. Because both the LLCP and the LDL-HDL transition line lie in water's "no man's land" between the homogeneous nucleation temperature (TH, 232 K) and the crystallization temperature (TX, 150 K), the success of experiments exploring this region has been limited thus far. Using a rapid decompression technique integrated with in situ x-ray diffraction, we observe that a high-pressure ice phase transforms to a low-density noncrystalline (LDN) form upon rapid release of pressure at temperatures of 140-165K. The LDN subsequently crystallizes into ice-Ic through a diffusion-controlled process. The change in crystallization rate with temperature indicates that the LDN is a LDL with its tetrahedrally-coordinated network fully developed and clearly linked to low-density amorphous ices. The observation of the tetrahedral LDL supports the two-liquid model for water including the existence of a LLCP.

  20. 22 CFR 1104.2 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Relations INTERNATIONAL BOUNDARY AND WATER COMMISSION, UNITED STATES AND MEXICO, UNITED STATES SECTION... Commission, United States and Mexico, and his delegate. (d) Public lands means lands to which the United... Boundary and Water Commission, United States and Mexico. (e) Indian tribe as defined in the Act means any...

Top