Evaluation of 3 dental unit waterline contamination testing methods
Porteous, Nuala; Sun, Yuyu; Schoolfield, John
2015-01-01
Previous studies have found inconsistent results from testing methods used to measure heterotrophic plate count (HPC) bacteria in dental unit waterline (DUWL) samples. This study used 63 samples to compare the results obtained from an in-office chairside method and 2 currently used commercial laboratory HPC methods (Standard Methods 9215C and 9215E). The results suggest that the Standard Method 9215E is not suitable for application to DUWL quality monitoring, due to the detection of limited numbers of heterotrophic organisms at the required 35°C incubation temperature. The results also confirm that while the in-office chairside method is useful for DUWL quality monitoring, the Standard Method 9215C provided the most accurate results. PMID:25574718
Microbial quality of water in dental unit waterlines.
Nikaeen, Mahnaz; Hatamzadeh, Maryam; Sabzevari, Zohre; Zareh, Omolbanin
2009-09-01
Dental unit waterlines (DUWLs) are ideal environment for development of microbial biofilms. Microbial contamination of water in DUWLs is thought to be the result of biofilm formation as it could serves as a haven for pathogens. The aim of this study was to assess microbial quality of water in dental unit waterlines of dental units located at the dental school of Isfahan University of Medical Sciences. Water samples were collected from air/water syringe and high-speed handpiece. Generally, 100-200 ml water samples were collected aseptically in sterile containers with sodium thiosulfate at the beginning of the day after a 2 minute purge. Samples were transferred to the laboratory in insulated box with cooling packs and examined for total viable heterotrophic bacteria and fungi. The heterotrophic plate count levels were significantly exceeded the American Dental Association recommendations for DUWL water quality (< 200 CFU/ml), in both air/water syringe (84%, CFU/ml: 500-20000) and high-speed handpiece (96%, CFU/ml: 710-36800) samples. However, there was no significant difference between the level of contamination in the air/water syringe and high-speed handpiece. Fungi were found in 28% and 36% of air/water syringe and high-speed handpiece samples, respectively; and filamentous fungi were the most frequently isolated fungi. DUWLs should be subjected to routine microbial monitoring and to a decontamination protocol in order to minimize the risk of exposure to potential pathogens from dental units.
Antifungal efficacy of hydrogen peroxide in dental unit waterline disinfection.
Szymańska, Jolanta
2006-01-01
The concentration and composition of fungal flora in dental unit waterlines (DUWL) were evaluated. For this purpose, water samples from unit reservoirs and high-speed handpieces, and biofilm samples from the waterline walls from units were collected. Subsequently, analogous samples from DUWL were taken before and after disinfection using agent containing hydrogen peroxide. In the examined samples, the yeast-like fungi Candida albicans and Candida curvata were found. The following species of mould were also identified: Aspergillus amstelodami, Aspergillus fumigatus, Aspergillus glaucus group, Aspergillus (=Eurotium herbariorum) repens, Citromyces spp., Geotrichum candidum, Penicillium (glabrum) frequentans, Penicillium pusillum, Penicillium turolense and Sclerotium sclerotiorum (Sclerotinia sclerotiorum). Before disinfection, Candida curvata and Candida albicans constituted the greatest proportion of the total fungi in the reservoirs water; in the water of handpieces--Candida albicans and Aspergillus glaucus group; and in the biofilm samples--Aspergillus glaucus group and Candida albicans. After disinfection, in all 3 kinds of samples, Candida albicans prevailed, constituting from 31.2-85.7 % of the total fungi. The application of agent containing hydrogen peroxide caused a significant decrease both in the number of total fungi and individual fungal species, which confirms the product effectiveness in fungal decontamination of DUWL.
Yoon, Hye Young; Lee, Si Young
2017-11-01
In this study, a laboratory model to reproduce dental unit waterline (DUWL) biofilms was developed using a CDC biofilm reactor (CBR). Bacteria obtained from DUWLs were filtered and cultured in Reasoner's 2A (R2A) for 10 days, and were subsequently stored at -70°C. This stock was cultivated on R2A in batch mode. After culturing for five days, the bacteria were inoculated into the CBR. Biofilms were grown on polyurethane tubing for four days. Biofilm accumulation and thickness was 1.3 × 10 5 CFU cm -2 and 10-14 μm respectively, after four days. Bacteria in the biofilms included cocci and rods of short and medium lengths. In addition, 38 bacterial genera were detected in biofilms. In this study, the suitability and reproducibility of the CBR model for DUWL biofilm formation were demonstrated. The model provides a foundation for the development of bacterial control methods for DUWLs.
Dallolio, Laura; Scuderi, Amalia; Rini, Maria S; Valente, Sabrina; Farruggia, Patrizia; Sabattini, Maria A Bucci; Pasquinelli, Gianandrea; Acacci, Anna; Roncarati, Greta; Leoni, Erica
2014-02-18
Output water from dental unit waterlines (DUWLs) may be a potential source of infection for both dental healthcare staff and patients. This study compared the efficacy of different disinfection methods with regard to the water quality and the presence of biofilm in DUWLs. Five dental units operating in a public dental health care setting were selected. The control dental unit had no disinfection system; two were disinfected intermittently with peracetic acid/hydrogen peroxide 0.26% and two underwent continuous disinfection with hydrogen peroxide/silver ions (0.02%) and stabilized chlorine dioxide (0.22%), respectively. After three months of applying the disinfection protocols, continuous disinfection systems were more effective than intermittent systems in reducing the microbial contamination of the water, allowing compliance with the CDC guidelines and the European Council regulatory thresholds for drinking water. P. aeruginosa, Legionella spp, sulphite-reducing Clostridium spores, S. aureus and β-haemolytic streptococci were also absent from units treated with continuous disinfection. The biofilm covering the DUWLs was more extensive, thicker and more friable in the intermittent disinfection dental units than in those with continuous disinfection. Overall, the findings showed that the products used for continuous disinfection of dental unit waterlines showed statistically better results than the intermittent treatment products under the study conditions.
Dallolio, Laura; Scuderi, Amalia; Rini, Maria S.; Valente, Sabrina; Farruggia, Patrizia; Bucci Sabattini, Maria A.; Pasquinelli, Gianandrea; Acacci, Anna; Roncarati, Greta; Leoni, Erica
2014-01-01
Output water from dental unit waterlines (DUWLs) may be a potential source of infection for both dental healthcare staff and patients. This study compared the efficacy of different disinfection methods with regard to the water quality and the presence of biofilm in DUWLs. Five dental units operating in a public dental health care setting were selected. The control dental unit had no disinfection system; two were disinfected intermittently with peracetic acid/hydrogen peroxide 0.26% and two underwent continuous disinfection with hydrogen peroxide/silver ions (0.02%) and stabilized chlorine dioxide (0.22%), respectively. After three months of applying the disinfection protocols, continuous disinfection systems were more effective than intermittent systems in reducing the microbial contamination of the water, allowing compliance with the CDC guidelines and the European Council regulatory thresholds for drinking water. P. aeruginosa, Legionella spp, sulphite-reducing Clostridium spores, S. aureus and β-haemolytic streptococci were also absent from units treated with continuous disinfection. The biofilm covering the DUWLs was more extensive, thicker and more friable in the intermittent disinfection dental units than in those with continuous disinfection. Overall, the findings showed that the products used for continuous disinfection of dental unit waterlines showed statistically better results than the intermittent treatment products under the study conditions. PMID:24552789
Costa, Damien; Mercier, Anne; Gravouil, Kevin; Lesobre, Jérôme; Verdon, Julien; Imbert, Christine
2016-10-01
Chemical disinfectants are widely advocated to reduce the microbial contamination in dental unit waterlines (DUWL). However, until now their efficacy has been poorly examined after long-term application. In this study, through quantitative PCR and high-throughput sequencing, both bacterial and fungal communities were profiled from 8- to 12-year-old DUWL treated with disinfectants commonly used by European dentists. Water was collected from the tap water supplying units to the output exposure point of the turbine handpiece following a stagnation period and dental care activity. Results showed that (i) the unit itself is the principal source of microbial contamination and (ii) water stagnation, DU maintenance practices and quality of water supplying DU appeared as parameters driving the water quality. Despite disinfecting treatment combined to flushing process, the microbial contamination remained relevant in the studied output water, in association with a high bacterial and fungal diversity. The occurrence of potentially pathogenic microorganisms in these treated DUWL demonstrated a potential infectious risk for both patients and dental staff. A disinfectant shock before a prolonged stagnation period could limit the microbial proliferation inside DUWL. Necessity to proceed to regular water quality control of DUWL was highlighted. © FEMS 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Legionella spp. in dental unit waterlines.
Sedlata Juraskova, E; Sedlackova, H; Janska, J; Holy, O; Lalova, I; Matouskova, I
2017-01-01
To determine the current presence of Legionella spp. in the output water of dental unit waterlines (DUWLs) and examine its mitigation by disinfection at the Institute of Dentistry and Oral Sciences, Faculty of Medicine and Dentistry, Palacky University Olomouc and University Hospital Olomouc. The first stage of our survey involved collecting samples of DUWL output water from 50 dental chair units (DCUs), and 2 samples of the incoming potable water. In October 2015, a one-time disinfection (1 % Stabimed) of DUWLs was conducted. This was followed by collecting 10 control samples (survey stage 2). From the total of 50 samples (survey stage 1), 18 samples (36.0 %) tested positive for Legionella spp. Following the disinfection, nine of the ten samples no longer showed any presence of Legionella. Based on culture results, the one-time disinfection (1 % Stabimed) was effective. We are unable to comment on the duration of positive effect of disinfection on the occurrence of Legionella spp. in the outlet water. It was a one-time survey (Tab. 2, Ref. 32).
Evaluation of mycological contamination of dental unit waterlines.
Szymańska, Jolanta
2005-01-01
The quality of dental unit water is of great importance since patients and dental staff are regularly exposed to water from aerosols generated during work. The main purpose of this investigation was mycological evaluation of dental unit waterlines (DUWL). The author determined the number and species of fungi present in the water from a unit reservoir which is the source of water for a dental unit, in the water flowing from a high-speed handpiece of a unit, and in the swab sample collected from the wall of a waterline connecting a unit reservoir and dental handpieces. The following mould fungi were identified: Aspergillus amstelodami, Aspergillus fumigatus, Aspergillus spp. from Aspergillus glaucus group, Aspergillus repens, Citromyces spp., Geotrichum candidum, Penicillium aspergilliforme, Penicillium pusillum, Penicillium turolense, Sclerotium sclerotiorum; yeast-like fungi: Candida albicans, Candida curvata and other yeasts. Some of them, in certain circumstances, especially in people with immunological disorders, may be a cause of opportunistic infections. Thus, it is necessary that the DUWL should be submitted to a decontamination protocol and to routine microbial monitoring to guarantee an appropriate quality of water used in dental treatment.
Ditommaso, Savina; Giacomuzzi, Monica; Ricciardi, Elisa; Zotti, Carla M
2016-02-06
Legionella spp. are ubiquitous in aquatic habitats and water distribution systems, including dental unit waterlines (DUWLs). The aim of the present study was to determine the prevalence of Legionella in DUWLs and tap water samples using PMA-qPCR and standard culture methods. The total viable counts (TVCs) of aerobic heterotrophic bacteria in the samples were also determined. Legionella spp. were detected and quantified using the modified ISO 11731 culture method. Extracted genomic DNA was analysed using the iQ-Check Quanti Legionella spp. kit, and the TVCs were determined according to the ISO protocol 6222. Legionella spp. were detected in 100% of the samples using the PMA-qPCR method, whereas these bacteria were detected in only 7% of the samples using the culture method. The number of colony forming units (CFUs) of the TVCs in the DUWL and tap water samples differed, with the bacterial load being significantly lower in the tap water samples (p-value = 0). The counts obtained were within the Italian standard range established for potable water in only 5% of the DUWL water samples and in 77% of the tap water samples. Our results show that the level of Legionella spp. contamination determined using the culture method does not reflect the true scale of the problem, and consequently we recommend testing for the presence of aerobic heterotrophic bacteria based on the assumption that Legionella spp. are components of biofilms.
Ditommaso, Savina; Giacomuzzi, Monica; Ricciardi, Elisa; Zotti, Carla M.
2016-01-01
Legionella spp. are ubiquitous in aquatic habitats and water distribution systems, including dental unit waterlines (DUWLs). The aim of the present study was to determine the prevalence of Legionella in DUWLs and tap water samples using PMA-qPCR and standard culture methods. The total viable counts (TVCs) of aerobic heterotrophic bacteria in the samples were also determined. Legionella spp. were detected and quantified using the modified ISO 11731 culture method. Extracted genomic DNA was analysed using the iQ-Check Quanti Legionella spp. kit, and the TVCs were determined according to the ISO protocol 6222. Legionella spp. were detected in 100% of the samples using the PMA-qPCR method, whereas these bacteria were detected in only 7% of the samples using the culture method. The number of colony forming units (CFUs) of the TVCs in the DUWL and tap water samples differed, with the bacterial load being significantly lower in the tap water samples (p-value = 0). The counts obtained were within the Italian standard range established for potable water in only 5% of the DUWL water samples and in 77% of the tap water samples. Our results show that the level of Legionella spp. contamination determined using the culture method does not reflect the true scale of the problem, and consequently we recommend testing for the presence of aerobic heterotrophic bacteria based on the assumption that Legionella spp. are components of biofilms. PMID:26861373
Ji, Xue-Yue; Fei, Chun-Nan; Zhang, Ying; Zhang, Wei; Liu, Jun; Dong, Jie
2016-08-01
Dental unit waterline (DUWL) output water is delivered through instruments of a dental chair unit (DCU) to irrigate and cool teeth. However, these waterlines can be heavily contaminated with bacteria. The purpose of the present study was to assess retraction and investigate the contamination level and prevalence of bacteria in DUWL output water. Fifty-eight DCUs were randomly selected from 30 hospitals in 10 districts of Tianjin, one of the four special municipalities of China. A unique sampling connector was used in place of the dental handpiece to collect water samples. Evaluation of retraction was accomplished using a retraction measurement device designed in accordance with the International Standard ISO 7494-2:2015(E). A total of 263 water samples were collected, and the highest concentration of bacteria [1.8 × 10(6) colony-forming units (CFU)/mL] was found in the handpiece group. Thirty (51.72%) water samples in the handpiece group and 21 (36.21%) in the air/water syringe groups were cultured, yielding colony counts of > 500 CFU/mL. Potential infectious agents, such as Bacillus cereus, Kocuria kristinae and Pseudomonas fluorescens, were isolated from the water samples. Thirty (51.72%) DCUs failed the retraction evaluation. There was a significant, positive correlation (P < 0.05) between the concentration of bacteria in the water sample and the retracted volume. It is of paramount importance to increase compliance with the standards for controlling DUWL contamination. Routine microbial monitoring and evaluation of retraction are necessary to provide high-quality water for use in dental treatment. © 2016 FDI World Dental Federation.
Lal, Sham; Singhrao, Sim K; Achilles-Day, Undine E M; Morton, L H Glyn; Pearce, Mark; Crean, StJohn
2015-10-01
Vermamoeba vermiformis is associated with the biofilm ecology of dental-unit waterlines (DUWLs). This study investigated whether V. vermiformis is able to act as a vector for potentially pathogenic bacteria and so aid their dispersal within DUWL systems. Clinical dental water was initially examined for Legionella species by inoculating it onto Legionella selective-medium plates. The molecular identity/profile of the glassy colonies obtained indicated none of these isolates were Legionella species. During this work bacterial colonies were identified as a non-pigmented Serratia marcescens. As the water was from a clinical DUWL which had been treated with Alpron™, this prompted the question as to whether S. marcescens had developed resistance to the biocide. Exposure to Alpron™ indicated that this dental biocide was effective, under laboratory conditions, against S. marcescens at up to 1 × 10(8) colony forming units/millilitre (cfu/ml). V. vermiformis was cultured for 8 weeks on cells of S. marcescens and Escherichia coli. Subsequent electron microscopy showed that V. vermiformis grew equally well on S. marcescens and E. coli (P = 0.0001). Failure to detect the presence of S. marcescens within the encysted amoebae suggests that V. vermiformis is unlikely to act as a vector supporting the growth of this newly isolated, nosocomial bacterium.
Porteous, Nuala; Luo, Jie; Hererra, Monica; Schoolfield, John; Sun, Yuyu
2011-01-01
This study examined bacterial growth and type on biofilm-controlling dental unit waterline (DUWL) tubing (T) and control manufacturer's tubing (C) in a laboratory DUWL model using ultrapure source water that was cycled through the lines. Sections of tubing lines were detached and examined for biofilm growth using SEM imaging at six sampling periods. Bacteria from inside surfaces of T and C, source unit, and reservoir were cultured and enumerated. At six months, organisms were molecularly identified from the alignment matches obtained from the top three BLAST searches for the 16S region. There was a 1–3 log increase in organism growth in a clean, nonsterile reservoir within an hour. Biofilm was established on the inside surfaces of C within three weeks, but not on T. Proteobacteria, and Sphingomonas spp. were identified in the source reservoir and C line, and a variation of the genera was found in T line. PMID:22220171
Dental unit water lines (DUWL) are susceptible to biofilm development and bacterial growth leading to water contamination, causing health and ecological effects. This study monitors the interactions between a commonly used nanosilver disinfectant (ASAP-AGX-32, an antimicrobial c...
Microbial contamination of dental unit waterlines and effect on quality of indoor air.
Kadaifciler, Duygu Göksay; Cotuk, Aysin
2014-06-01
The microbiological quality in dental unit waterlines (DUWLs) is considered to be important because patients and dental staff with suppressed immune systems are regularly exposed to water and aerosols generated from dental units (DUs). Opportunistic pathogens like Pseudomonas, Legionella, Candida, and Aspergillus can be present in DUWLs, while during consultations, bioaerosols can be dispersed in the air, thus resulting in effects on microbiological quality of indoor air. This present study represents microbiological air and water quality in dental offices (DOs) and also concerns the relationship between the quality of DO air and dental unit water. This study aimed to assess both the microbial quality of dental unit water and the indoor air in 20 DOs and to survey the effect on the quality of the indoor air with the existing microorganisms in dental unit water. Fourteen out of 20 (70 %) DUWLs were found to be contaminated with a high number of aerobic mesophilic heterotrophic bacteria. In terms of bacterial air contamination levels, in 90 % of DOs, a medium level (<500 colony-forming units (CFU)/m(3)) of contamination was determined, while in terms of microfungal air contamination, in all DOs, a low level (<100 CFU/m(3)) of contamination was determined. Potential infection or allergen agents, such as Pseudomonas, Micrococcus, Staphylococcus, Alternaria, Cladosporium, Penicillium, Aspergillus, and Paecilomyces were isolated from water and air samples. This study's determination of contamination sources and evaluation of microbial load in DOs could contribute to the development of quality control methods in the future.
Chate, R A C
2006-11-11
To improve the quality of water emanating from dental unit waterlines (DUWLs). A prospective clinical audit. Three geographically separate district dental facilities of a United Kingdom NHS Trust, involving two community clinics and one hospital orthodontic department, which were evaluated between 2002 and 2004. Samples of water discharged from the DUWLs were collected prior to the start and midway through a morning session. These were tested microbiologically at a United Kingdom Accreditation Service testing laboratory within six hours of sampling. One of the clinics followed the contemporaneous BDA advice of flushing water through its DUWLs while the other two clinics used separate intermittent disinfection purging regimes instead. One of them used a two stage protocol of Ethylene Diamine Tetra-Acetic acid followed by hydrogen peroxide, while the other used Bio 2000 as a single agent, which was subsequently superseded by the continuous use of super-oxidised water (Sterilox). To assess whether the samples either met the American Dental Association's guideline on the quality of DUWL water, or the more stringent European Union standards for potable (drinking) water. The two units which used a disinfection regime both complied with the ADA guideline and the EU potable water standard. However, the unit which only flushed through its DUWLs without using a disinfectant failed to comply with either of them. After all three dental facilities subsequently standardised their DUWL disinfection regimes by using Bio 2000, the colony counts from all of the water samples thereafter remained well below the EU recommended level. The unit which progressed to using Sterilox as a continuous disinfectant achieved and maintained zero readings from its water samples. Clinical audit can result in the improvement of the quality of water that is discharged through DUWLs, thereby minimising both the risk of cross infection to vulnerable patients, as well as to dental staff chronically exposed to contaminated aerosols.
Mycological contamination in dental unit waterlines in Istanbul, Turkey
Kadaifciler, Duygu Göksay; Ökten, Suzan; Sen, Burhan
2013-01-01
Studies on dental units (DUs) are conducted either for the prevention or the reduction of the density of bacterial contamination in dental unit waterlines (DUWLs). However, the existence of fungi in the these systems requires more attention. During dental treatment, direct contact with water contaminated with fungi such as Candida, Aspergillus, or inhalation of aerosols from high-speed drill may cause various respiratory infections, such as asthma, allergies, and wounds on mucose membranes, especially on immunocompromised patients and dentists. The aims of this study are to investigate the number and colonization of fungi in DUWLs in the city of Istanbul, Turkey. Water samples were collected from air-water syringes, high-speed drills, and inlet waters from 41 DUs. The aerobic mesophilic fungi count in high- speed drills was higher than inlet waters and air-water syringes. Non-sporulating fungi were found in 7 DUs. The isolated fungi were identified as Penicillium waksmanii, Cladosporium spp., Penicillium spp., Candida famata, Cryptococcus laurentii, Candida guilliermondii, Penicillium verrucosum, Aspergillus pseudoglaucus, Penicillium decumbens, and Acremonium sp. Some of these fungal genera are known as opportunistic pathogens that led to respiratory diseases such as allergic rhinits. This study shows the importance of regular control of mycological contamination on water at DUs. PMID:24516467
Effect of 0.2% chlorhexidine on microbial and fungal contamination of dental unit waterlines
Agahi, Raha Habib; Hashemipour, Maryam Alsadat; Kalantari, Mahsa; Ayatollah-Mosavi, Amin; Aghassi, Hossein; Nassab, Amir Hossein Gandjalikhan
2014-01-01
Background: It is known that dental unit waterline can be a source of infection. The aim of this study was to evaluate the efficacy of a mouthwash, chlorhexidine, in controlling microbial and fungal contamination of dental unit waterlines. Materials and Methods: In the present experimental study, the water in high-speed handpieces and air/water syringes of 35 dental units in a dental school was investigated microbiologically. Five of the units and one tap water served as controls; 100-200-mL water samples were collected aseptically in sterile containers in the morning after a 2-min purge. Water reservoir bottles were emptied and 50 mL of 0.2% chlorhexidine mouthwash was introduced into the tank. Then the water syringe was used to flush the waterline until the pink-colored chlorhexidine was observed to flow from the water syringe. Before the next day's session and before the students used the unit, two water samples from the water syringe and water turbine was collected. The samples were transferred to the laboratory. After 48 h at 37°C, the microbial colonies were counted. The number of these colonies was evaluated using colony forming unit CFU. Data were analyzed with Mann — Whitney U test and SPSS 13.5 statistical program. The statistical significance was defined at P ≤ 0.05. Results: All 35 units were contaminated before chlorhexidine use; no contamination was detected after adding chlorhexidine to the waterlines of the units. After week 1, 28 of the 30 treated dental unit waterlines (DUWLs) had values of CFU/mL less than 200. Conclusion: The present study showed that the use of chlorhexidine could reduce microbial counts in dental unit waterlines. PMID:25097645
Effect of 0.2% chlorhexidine on microbial and fungal contamination of dental unit waterlines.
Agahi, Raha Habib; Hashemipour, Maryam Alsadat; Kalantari, Mahsa; Ayatollah-Mosavi, Amin; Aghassi, Hossein; Nassab, Amir Hossein Gandjalikhan
2014-05-01
It is known that dental unit waterline can be a source of infection. The aim of this study was to evaluate the efficacy of a mouthwash, chlorhexidine, in controlling microbial and fungal contamination of dental unit waterlines. In the present experimental study, the water in high-speed handpieces and air/water syringes of 35 dental units in a dental school was investigated microbiologically. Five of the units and one tap water served as controls; 100-200-mL water samples were collected aseptically in sterile containers in the morning after a 2-min purge. Water reservoir bottles were emptied and 50 mL of 0.2% chlorhexidine mouthwash was introduced into the tank. Then the water syringe was used to flush the waterline until the pink-colored chlorhexidine was observed to flow from the water syringe. Before the next day's session and before the students used the unit, two water samples from the water syringe and water turbine was collected. The samples were transferred to the laboratory. After 48 h at 37°C, the microbial colonies were counted. The number of these colonies was evaluated using colony forming unit CFU. Data were analyzed with Mann - Whitney U test and SPSS 13.5 statistical program. The statistical significance was defined at P ≤ 0.05. All 35 units were contaminated before chlorhexidine use; no contamination was detected after adding chlorhexidine to the waterlines of the units. After week 1, 28 of the 30 treated dental unit waterlines (DUWLs) had values of CFU/mL less than 200. The present study showed that the use of chlorhexidine could reduce microbial counts in dental unit waterlines.
Pyrosequencing analysis of bacterial diversity in dental unit waterlines.
Costa, Damien; Mercier, Anne; Gravouil, Kevin; Lesobre, Jérôme; Delafont, Vincent; Bousseau, Anne; Verdon, Julien; Imbert, Christine
2015-09-15
Some infections cases due to exposure to output water from dental unit waterlines (DUWL) have been reported in the literature. However, this type of healthcare-associated risk has remained unclear and up until now the overall bacterial composition of DUWL has been poorly documented. In this study, 454 high-throughput pyrosequencing was used to investigate the bacterial community in seven dental offices (N = 7) and to identify potential bacterial pathogenic sequences. Dental unit waters (DUW) were collected from the tap water supplying units (Incoming Water; IW) to the output exposure point of the turbine handpiece (Output water; OW) following a stagnation period (OWS), and immediately after the last patient of the sampling day (OWA). A high bacterial diversity was revealed in DUW with 394 operational taxonomic units detected at the genus level. In addition to the inter-unit variability observed, results showed increased total bacterial cell concentration and shifts in bacterial community composition and abundance at the genus level, mainly within the Gamma- and Alpha-Proteobacteria class, as water circulated in the dental unit (DU). Results showed that 96.7%, 96.8% and 97.4% of the total sequences from IW, OWS and OWA respectively were common to the 3 defined water groups, thereby highlighting a common core microbiome. Results also suggested that stagnation and DU maintenance practices were critical to composition of the bacterial community. The presence of potentially pathogenic genera was detected, including Pseudomonas and Legionella spp. Emerging and opportunistic pathogenic genera such as Mycobacterium, Propionibacterium and Stenotrophomonas were likewise recovered in DUW. For the first time, an exhaustive evaluation of the bacterial communities present in DUW was performed taking into account the circulation of water within the DU. This study highlights an ignored diversity of the DUWL bacterial community. Our findings also contribute to a better appreciation of the potential infectious risk associated with dental care and suggest the importance of better managing microbial quality in DUW. Copyright © 2015 Elsevier Ltd. All rights reserved.
Nanosilver as a disinfectant in dental unit waterlines ...
Dental unit water lines (DUWL) are susceptible to biofilm development and bacterial growth leading to water contamination, causing health and ecological effects. This study monitors the interactions between a commonly used nanosilver disinfectant (ASAP-AGX-32, an antimicrobial cleaner for dental units, 0.0032% Ag) and biofilm development in DUWL. To simulate the disinfection scenario, an in-house DUWL model was assembled and biofilm accumulation was allowed. Subsequent to biofilm development, the disinfection process was performed according to the manufacturer's instructions. The pristine nanosilver particles in the cleaner measured between 3 and 5 nm in diameter and were surrounded by a stabilizing polymer. However, the polymeric stabilizing agent diminished over the disinfection process, initiating partial AgNPs aggregation. Furthermore, surface speciation of the pristine AgNPs were identified as primarily AgO, and after the disinfection process, transformations to AgCl were observed. The physicochemical characteristics of AgNPs are known to govern their fate, and transport and environmental implications. Hence, knowledge of the AgNPs characteristics after the disinfection process (usage scenario) is of significance. This study demonstrates the adsorption of AgNPs onto biofilm surfaces and, therefore, will assist in illustration of the toxicity mechanisms of AgNPs to bacteria and biofilms. This work can be an initial step in better understanding how
Evaluation of the Antimicrobial Functions of N-halamine Dental Unit Waterline Tubing for One Year.
Porteous, N; Dang, S; Schoolfield, J; Sun, Y
2016-03-01
The objective of this study was to test the biofilm-controlling properties of N-halamine antimicrobial dental unit waterline (DUWL) tubing (T) tubing, without recharging over one year, compared to a control line (C). A simulated clinical model was used to pump ultrapure water through T and C lines at a rate of 1.4 mL/min, five minutes on, 15 minutes off, eight hours/day, five days a week. Samples of source water, effluent from T and C, and from the stagnant water in the carboy (liquid container) after bench work was completed (S2), were collected aseptically, serially diluted, and cultured on R2A agar for seven days every six weeks. SEM images of the inside surfaces of detached tubing sections were also taken. The carboy was rinsed with a 1:10 dilution of sodium hypochlorite after six months. Means of log transformed CFU values obtained in triplicate were paired by T and C lines across months for comparison by paired Student's t-tests. An increase in effluent and carboy bacterial counts were noted after six months, but decreased after bleach rinse of the carboy. No significant difference (p > 0.25) between T and C lines were observed; similarly, T and carboy were not significantly different (p > 0.30). SEM images showed biofilm attachment on the inside surface of C after two months, but not on T. Organisms identified in the effluent reflected those in the source carboy. No biofilm attachment was detected on the N-halamine test line after 12 months, indicating its antimicrobial properties were retained. Further evaluation is recommended to determine the optimal recharge interval for N-halamine DUWL tubing when ultrapure source water is used.
Evaluation of the Antimicrobial Functions of N-halamine Dental Unit Waterline Tubing for One Year
Porteous, N.; Dang, S.; Schoolfield, J.; Sun, Y.
2017-01-01
Objective The objective of this study was to test the biofilm-controlling properties of N-halamine antimicrobial dental unit waterline (DUWL) tubing (T) tubing, without recharging over one year, compared to a control line (C). Methods A simulated clinical model was used to pump ultrapure water through T and C lines at a rate of 1.4 mL/min, five minutes on, 15 minutes off, eight hours/day, five days a week. Samples of source water, effluent from T and C, and from the stagnant water in the carboy (liquid container) after bench work was completed (S2), were collected aseptically, serially diluted, and cultured on R2A agar for seven days every six weeks. SEM images of the inside surfaces of detached tubing sections were also taken. The carboy was rinsed with a 1:10 dilution of sodium hypochlorite after six months. Means of log transformed CFU values obtained in triplicate were paired by T and C lines across months for comparison by paired Student’s t-tests. Results An increase in effluent and carboy bacterial counts were noted after six months, but decreased after bleach rinse of the carboy. No significant difference (p > 0.25) between T and C lines were observed; similarly, T and carboy were not significantly different (p > 0.30). SEM images showed biofilm attachment on the inside surface of C after two months, but not on T. Organisms identified in the effluent reflected those in the source carboy. Conclusions No biofilm attachment was detected on the N-halamine test line after 12 months, indicating its antimicrobial properties were retained. Further evaluation is recommended to determine the optimal recharge interval for N-halamine DUWL tubing when ultrapure source water is used. PMID:28390212
Dental unit water lines decontamination with the aid of nanotechnology.
Paramashivaiah, Rashmi; Prabhuji, M L V; Narayanan, Roopalakshmi
2016-01-01
This article reviews the issue of dental unit waterline (DUWL) contamination which affects all the clinical and hospital settings. The contaminating microorganisms commonly isolated from these settings and the most pathogenic among them have serious consequences. Over the years several measures are inculcated for decontamination of water, their advantages and shortcomings have been addressed. Options using nanotechnology which are available in the market are described briefly. A manual and electronic search was conducted. Google and PubMed were searched for relevant material from studies up to 2013. Medical Subject Headings words looked for were "Nanotechnology," "Water purification," and "Biofilms." Reviewed findings were summarized by topic, using the Preferred Reporting Items for Systematic Reviews and Meta-analyses statement for reporting. Seventy articles were shortlisted for articles pertaining to our topic of discussion. A systematic approach was followed by two independent reviewers and included eligibility criteria for study inclusion, data extraction, data synthesis, and drawing of conclusion. Dental waterline contamination is widespread in any type of dental setting having serious implications on clinicians and patients alike, especially elderly and immune-compromised. Hence, international bodies like center for disease and control and American Dental Association have come up with stringent measures for maintenance of water quality. A gamut of procedures has been tried to overcome this problem ranging from chlorinated products, water filters to the usage of distilled water. The use of nanoemulsions, nanofilters, nanomembranes, etc., and their applicability for routine usage is discussed. Biofilm formation in DUWLs is inevitable with the subsequent release of part of microbiota into the otherwise sterile dental settings. These consequences can be quite serious on clinicians and dental patients. Though conventional measures in water decontamination have been partly successful, the quest for more foolproof methods has led to the use of latest technology, i.e., nanotechnology. The most practical option has to be chosen based on the ease of their usage.
Ditommaso, Savina; Giacomuzzi, Monica; Ricciardi, Elisa; Zotti, Carla M
2016-07-22
This study was designed to examine the in vitro bactericidal activity of hydrogen peroxide against Legionella. We tested hydrogen peroxide (Peroxy Ag⁺) at 600 ppm to evaluate Legionella survival in a simulated dental treatment water system equipped with Water Hygienization Equipment (W.H.E.) device that was artificially contaminated. When Legionella pneumophila serogroup (sg) 1 was exposed to Peroxy Ag⁺ for 60 min we obtained a two decimal log reduction. High antimicrobial efficacy was obtained with extended periods of exposure: four decimal log reduction at 75 min and five decimal log reduction at 15 h of exposure. Involving a simulation device (Peroxy Ag⁺ is flushed into the simulation dental unit waterlines (DUWL)) we obtained an average reduction of 85% of Legionella load. The product is effective in reducing the number of Legionella cells after 75 min of contact time (99.997%) in the simulator device under test conditions. The Peroxy Ag⁺ treatment is safe for continuous use in the dental water supply system (i.e., it is safe for patient contact), so it could be used as a preventive option, and it may be useful in long-term treatments, alone or coupled with a daily or periodic shock treatment.
Breaking the Chain of Infection: Dental Unit Water Quality Control
Pawar, Amrita; Mehta, Sonia; Dang, Rajat
2016-01-01
Introduction The air–water syringes, ultrasonic scalers, high speed air turbine handpieces are connected to dental units by a network of small-bore plastic tubes through which water and air travel to activate or cool the instruments and it had been shown that this system is extensively contaminated with microbial biofilms and pose a potential risk of infection for patients as well as dental professionals. Aim To evaluate and compare the efficacy of various disinfectants in reducing the microbial colony count in water derived from Dental Unit Waterlines. Materials and Methods Five random dental units were selected and samples were collected before and after intervention with 5 disinfectants (0.02% H2O2 continuously, 0.02% H2O2 continuously with shock treatment with 0.25% H2O2 weekly, 0.12% Chlorohexidine and 12% Ethanol overnight, 1:50 Original Listerine overnight, 2% Sodium Perborate and 2% EDTA 5 minutes in morning) using different disinfection methods for 4 weeks. Samples were cultured on Reasoner’s 2A (R2A) agar for microbial counting. Results Results were recorded as Colony forming units/ml (cfu/ml) and were evaluated statistically. Results showed that all the dental unit waterlines were heavily contaminated with microbes before any intervention. After 1 day of disinfection regime the counts reduced significantly and showed progressive reduction in consecutive weeks. Goals set by ADA & CDC were ultimately achieved at the end of 4 weeks. Conclusion All the disinfectants were equally effective in reducing the microbial colony count of DUWLs, irrespective of their concentration and method of disinfection. PMID:27630960
Breaking the Chain of Infection: Dental Unit Water Quality Control.
Pawar, Amrita; Garg, Sandeep; Mehta, Sonia; Dang, Rajat
2016-07-01
The air-water syringes, ultrasonic scalers, high speed air turbine handpieces are connected to dental units by a network of small-bore plastic tubes through which water and air travel to activate or cool the instruments and it had been shown that this system is extensively contaminated with microbial biofilms and pose a potential risk of infection for patients as well as dental professionals. To evaluate and compare the efficacy of various disinfectants in reducing the microbial colony count in water derived from Dental Unit Waterlines. Five random dental units were selected and samples were collected before and after intervention with 5 disinfectants (0.02% H2O2 continuously, 0.02% H2O2 continuously with shock treatment with 0.25% H2O2 weekly, 0.12% Chlorohexidine and 12% Ethanol overnight, 1:50 Original Listerine overnight, 2% Sodium Perborate and 2% EDTA 5 minutes in morning) using different disinfection methods for 4 weeks. Samples were cultured on Reasoner's 2A (R2A) agar for microbial counting. Results were recorded as Colony forming units/ml (cfu/ml) and were evaluated statistically. Results showed that all the dental unit waterlines were heavily contaminated with microbes before any intervention. After 1 day of disinfection regime the counts reduced significantly and showed progressive reduction in consecutive weeks. Goals set by ADA & CDC were ultimately achieved at the end of 4 weeks. All the disinfectants were equally effective in reducing the microbial colony count of DUWLs, irrespective of their concentration and method of disinfection.
Rechargeable biofilm-controlling tubing materials for use in dental unit water lines.
Luo, Jie; Porteous, Nuala; Sun, Yuyu
2011-08-01
A simple and practical surface grafting approach was developed to introduce rechargeable N-halamine-based antimicrobial functionality onto the inner surfaces of continuous small-bore polyurethane (PU) dental unit waterline (DUWL) tubing. In this approach, tetrahydrofuran (THF) solution of a free-radical initiator, dicumyl peroxide (DCP), flowed through the PU tubing (inner diameter of 1/16 in., or 1.6 mm) to diffuse DCP into the tubing's inner walls, which was used as initiator in the subsequent grafting polymerization of methacrylamide (MAA) onto the tubing. Upon chlorine bleach treatment, the amide groups of the grafted MAA side chains were transformed into acyclic N-halamines. The reactions were confirmed with attenuated total reflectance infrared (ATR) spectra and iodometric titration. The mechanical properties of the tubing were not significantly affected by the grafting reactions. The biofilm-controlling function of the new N-halamine-based PU tubing was evaluated with Pseudomonas aeruginosa (P. aeruginosa), one of the most isolated water bacteria from DUWLs, in a continuous bacterial flow model. Bacteria culturing and SEM studies showed that the inner surfaces of the new N-halamine-based PU tubing completely prevented bacterial biofilm formation for at least three to four weeks. After that, bacteria began to colonize the tubing surface. However, the lost function was fully regenerated by exposing the tubing inner surfaces to diluted chlorine bleach. The recharging process could be repeated periodically to further extend the biofilm-controlling duration for long-term applications.
Rechargeable Biofilm-Controlling Tubing Materials for Use in Dental Unit Water Lines
Luo, Jie; Porteous, Nuala; Sun, Yuyu
2011-01-01
A simple and practical surface grafting approach was developed to introduce rechargeable N-halamine-based antimicrobial functionality onto the inner surfaces of continuous small-bore polyurethane (PU) dental unit waterline (DUWL) tubing. In this approach, tetrahydrofuran (THF) solution of a free-radical initiator, dicumyl peroxide (DCP), flowed through the PU tubing (inner diameter of 1/16 inch, or 1.6 mm) to diffuse DCP into the tube’s inner walls, which was used as initiator in the subsequent grafting polymerization of methacrylamide (MAA) onto the tubing. Upon chlorine bleach treatment, the amide groups of the grafted MAA side chains were transformed into acyclic N-halamines. The reactions were confirmed with attenuated total reflectance infrared (ATR) spectra and iodometric titration. The mechanical properties of the tubing were not significantly affected by the grafting reactions. The biofilm-controlling function of the new N-halamine-based PU tubing was evaluated with Pseudomonas aeruginosa (P. aeruginosa), one of the most isolated water bacteria from DUWLs, in a continuous bacterial flow model. Bacteria culturing and SEM studies showed that the inner surfaces of the new N-halamine-based PU tubing completely prevented bacterial biofilm formation for at least three to four weeks. After that, bacteria began to colonize the tubing surface. However, the lost function was fully regenerated by exposing the tubing inner surfaces to diluted chlorine bleach. The recharging process could be repeated periodically to further extend the biofilm-controlling duration for long-term applications. PMID:21721534
Petti, Stefano; Moroni, Catia; Messano, Giuseppe Alessio; Polimeni, Antonella
2013-03-01
Oral streptococci detected in water from dental unit water lines (DUWLs) are a surrogate marker of patients' biological fluid retraction during therapy. We investigated oral streptococci detection rate in DUWLs in a representative sample of private offices in real-life conditions. Samples of nondisinfected water (100 ml) were collected from the DUWL designated for the air turbine handpiece in 81 dental units, immediately after dental treatment of patients with extensive air turbine handpiece use. Water was filtered and plated on a selective medium for oral streptococci and, morphologically, typical colonies of oral streptococci were counted. The lowest detection limit was 0.01 CFU/ml. The oral streptococci detection rate was 72% (95% CI: 62-81%), with a mean level of 0.7 CFU/ml. Oral streptococci detection was not affected by handpiece age or dental treatment type, but was associated with dental unit age. Biological fluid retraction into DUWLs during patient treatment and, possibly, the risk for patient-to-patient blood- or air-borne pathogen transmission are more frequent than expected.
Shajahan, Irfana Fathima; Kandaswamy, Deivanayagam; Lakshminarayanan, L.; Selvarajan, R.
2017-01-01
Objective: The purpose of the study was to examine the substantivity of a new disinfectant against biofilm formation in the dental unit waterlines. Materials and Methods: Twenty dental units were selected for the study and divided into two groups: Group A (dental unit waterlines treated with the disinfectant) and Group B (untreated dental unit waterlines). Biofilm formation was monitored in both groups by removing the one dental unit waterline from each group for the period of 10 days. One inch of the dental unit waterline tube was cut at random site, and the inner lumen of the cut sections was analyzed using the scanning electron microscope (SEM) (TESCAN VEGA3 SBU). Results: On examination, SEM images showed that there was no slime layer or bacterial cells seen in cut section for the period of 7 days in the treated dental waterlines, which means that there is no evident of biofilm formation. In the untreated dental unit waterline cut section, slime layer was observed from day 1. Conclusion: Disinfectant solution was proved to be effective for 7 days against biofilm formation. This technique could be used as a valid method for disinfection of dental unit waterlines. PMID:28761244
Dental unit waterlines disinfection using hypochlorous acid-based disinfectant
Shajahan, Irfana Fathima; Kandaswamy, D; Srikanth, Padma; Narayana, L Lakshmi; Selvarajan, R
2016-01-01
Objective: The purpose of the study was to investigate the efficacy of a new disinfectant to disinfect the dental unit waterlines. Materials and Methods: New dental unit waterlines were installed in 13 dental chairs, and biofilm was allowed to grow for 10 days. Disinfection treatment procedure was carried out in the 12 units, and one unit was left untreated. The dental unit waterlines were removed and analyzed using the scanning electron microscope (SEM) (TESCAN VEGA3 SBU). Result: On examination, SEM images showed that there was no slime layer or bacterial cells seen in any of the 12 cut sections obtained from the treated dental waterlines which mean that there was no evident of biofilm formation. Untreated dental unit waterlines showed a microbial colonization with continuous filamentous organic matrix. There was significant biofilm formation in the control tube relative to the samples. Conclusion: The tested disinfectant was found to be effective in the removal of biofilm from the dental unit waterlines. PMID:27563184
Microbial contamination of dental unit waterlines: short- and long-term effects of flushing.
Santiago, J I; Huntington, M K; Johnston, A M; Quinn, R S; Williams, J F
1994-01-01
The extensive microbial contamination of DUW in this study is consistent with that described in previous reports. Comparisons with other common public potable water sources emphasize the relatively high concentrations of microorganisms in DUW, and the low numbers of bacteria in most domestic water samples. Microscopic evidence of amebas and worms in DUW reinforces the need for further qualitative and quantitative studies of these contaminants of dental tubing biofilm. In most cases, flushing for two minutes reduced microbial concentrations in DUW. However, in a few cases, concentrations rose; in others, the reductions were negligible. Moreover, after 30 minutes of stasis, or use of the waterline in a routine dental procedure, microbial counts were frequently restored to preflush levels or higher. The longer-term ineffectiveness 30 minutes after flushing is understandable when the hydrodynamics of laminar flow of water in narrow-bore tubing are considered. Biofilm on the tubing wall remains intact during flushes and quickly generates more bacteria during stasis. Increased bacterial concentrations after flushing probably result from sloughing of biofilm from the tubing wall because of stretching and movement of the line during routine use. These two phenomena undermine the benefits of routine water flushes. It is a common belief that bacterial levels build to extremes during overnight or weekend stasis; we observed more variation in contamination levels during the workday than between overnight stasis and typical workday samples. The presence of hemolytic staphylococci and streptococci in water samples from lines that were supplied only from sterile water reservoirs adds to the growing evidence that part of the microbial flora in DUWLs may be derived from patients' mouths. Additional prophylactic measures to limit bacterial contamination in DUW should be implemented according to standard principles used in other medical fluid delivery devices.
Berlutti, Francesca; Testarelli, Luca; Vaia, Francesco; De Luca, Massimo; Dolci, Giovanni
2003-02-01
In this study we examine the efficacy of anti-retraction devices in preventing microbial contamination of dental unit water lines (DUWLs). The study was performed on 54 randomly selected DUs in use at private and public institutions for over six months. The selected DUs were all currently commercially available. To evaluate the efficiency of anti-retraction devices, two different methods were employed, mechanical and microbiological. The ADA/ANSI specification #47 (corresponding to a water retraction of less than 40.3 microl) was used for the evaluation of the retraction determined using the mechanical method; the presence/absence of test microorganisms in DUWLs upstream the turbine after the test was used for evaluating the microbiological assay. Both evaluation methods indicated correct amounts of retraction and prevention of DUWL contamination occurred in only two cases (3.7%). Correct retraction was noted in six other dental units (DUs), but their DUWLs became contaminated during testing. Six other produced the opposite results-improper retraction, yet no contamination. The remaining 40 DUs (74.0%) failed both evaluations. The results showed that the overwhelming majority of the anti-retraction devices did not prevent retraction when the turbine stopped running, leading to a contamination of the water lines, and to a consequent possible cross-contamination of the patients.
Laboratory evaluation of anti-biofilm agents for use in dental unit waterlines.
Meiller, T F; Kelley, J I; Baqui, A A; DePaola, L G
2001-01-01
Dental unit waterline biofilm has been recognized as a potential point of contamination and a risk to patients with any level of immunocompromise. Biofilm in dental unit waterlines, once established, has proven formidable to efforts in disinfection/disruption. This project compared standardized evaluation techniques by assessing the efficacy of a variety of agents that have been reported or suggested as useful in surface disinfection and/or antiseptic protocols. The zones of inhibition, minimum inhibitory/bactericidal concentrations and use-dilution with stainless steel carrier replicates tests assessed the disinfection of planktonic organisms using standardized microbial testing procedures. The disruption and/or disinfection of planktonic and biofilm organisms within naturally occurring dental unit waterlines were evaluated by culture and scanning electron microscopy. The six commercially available antimicrobial agents used to assess the techniques were bleach (sodium hypochlorite), Cavicide, glutaraldehyde, Listerine Antiseptic, Peridex and Sterilex Ultra. Comparisons between the results for each technique evaluated were determined for each product. All six agents demonstrated antimicrobial efficacy at the working concentrations designated by the manufacturers. Biofilm matrix elimination evaluated by scanning electron microscopy found virtually 0% elimination by glutaraldehyde to an estimated 90% elimination by Sterilex Ultra and bleach after one treatment. Treatment with Cavicide, Listerine Antiseptic and Peridex resulted in negligible elimination of the biofilm matrix. For comparability, the use of standardized testing techniques to evaluate a disinfection agent's efficacy against dental unit waterline contamination is essential. This project demonstrates a model system for evaluating disinfection agents potentially useful in the management of dental unit waterline biofilm, and should assist in educating the dental clinician in the appraisal of existing and future product claims.
Mungara, J; Dilna, N C; Joseph, E; Reddy, N
2013-01-01
The quality of water in a dental unit used for cooling and flushing the high and low speed handpiece, air/water syringes and the scalers is of considerable importance. The present study was carried out to enumerate and identify the microorganisms present in water samples collected from dental unit waterlines of different dental specialty clinics and to find out the efficacy of two treating agents in disinfecting dental unit waterlines. Sample included 70 dental unit waterlines from different speciality dental clinics which were checked for microbial contamination. From these dental units 40 units were randomly selected and divided into two groups of 20 each. Group A, treatment was done in 20 dental units with 0.2% Chlorhexidine gluconate solution and Group B, treatment was done in 20 dental units with 10% Povidone iodine solution and the reduction in the microbial levels were assessed. Five dental units were randomly selected and checked the microbial contamination using mineral water sterile distilled water fresh tap water as a water source in the dental unit reservoir bottles. Also from the test group, five from each group were checked for the duration of efficacy of treating agent for one week by analyzing the water samples collected on 3,5 and 7 day intervals. Most of the identified microorganisms are Gram negative and pseudomonas predominating up to 98.59% of the total isolates. Usage of disinfectants 0.2% Chlorhexidine and 10% Povidone Iodine were found to be very effective in reducing the microbial contamination and 10% Povidone iodine was found to be more efficient (97.13%) and active for a period of 3 days and gradually loosing its efficacy by 7th day. No significant difference were found in microbial contamination of water samples collected from different water outlets such as handpiece outlets, air water syringe outlets, scaler lines. To continue maintaining the sterility of the Dental unit waterlines and to complete the infection control measures adopted in the dental clinics, suitable disinfectants like 0.2% Chlorhexidine on daily basis or 10% Povidone iodine on every 3rd day basis intermittently maintain the sterility of dental unit waterlines it is essential to have a good water source and an effective disinfectant.
[Decontamination of dental unit waterlines using disinfectants and filters].
Monarca, S; Garusi, G; Gigola, P; Spampinato, L; Zani, C; Sapelli, P L
2002-10-01
Bacterial contamination of the dental unit water system can become a health problem for patients, particularly if they are immunodepressed. The present study has had the purpose of evaluating the effectiveness of methods of chemical decontamination using different disinfectants (peracetic acid, hydrogen peroxide, silver salts, chloramine T, glutaraldehyde T4) and methods of physical decontamination using synthetic membranes for the filtration of water. A preliminary removal procedure of the biofilm present in the waterline has been followed in a dental unit prepared on purpose for the research; subsequently different 2-week long maintenance procedures were applied using disinfectants injected by a pump and finally the bacterial contamination of the water flowing from the waterline was evaluated. The physical decontamination was performed using 0.22 mm membrane filters, which have been installed also in another dental unit, and the filtered water was analyzed to detect bacterial contamination. The preliminary procedure of biofilm removal succeeded obtaining germ-free water. Among the disinfectants used for the maintenance of the water quality only glutaraldehyde T4 was able to reduce the bacterial contamination under the limit suggested by the ADA. The membrane filter system was not able to purify the water, but when a disinfectant (peracetic acid) was used in the last part of the waterline good results were obtained. At present no decontamination system of dental waterline is available, and glutaraldehyde T4 seems to be the best disinfectant only if integrated with periodic biofilm removal for the maintenance of the water quality.
Effects of iodine in microbial control of dental treatment water.
Puttaiah, Raghunath; Seibert, Jeff; Spears, Robert
2011-05-01
To determine the effects of low levels of iodine constantly present in the dental unit water system on microbial control of dental treatment water and biofilm control. This study used a dental unit water system simulator with eight dental unit waterline systems built to scale and function, each controlled via computer. Each of the eight units was operated independently, four units supplied with self-contained water reservoirs and four units supplied with municipal water. Four units were precleaned to remove biofilm buildup. The study had a well-balanced design with equal representation (variables) of presence/absence of biofilms, selfcontained reservoirs for introduction of treatment water, source water directly connected to municipal water source and iodinated cartridges within the self-contained reservoirs and between municipal water and dental unit. Point-of-use iodinated resin cartridges (IRC) were retrofitted proximal to handpiece and air/ water syringe tip lines in four units, and iodinated resin water cartridges (IRSWC) were fitted to the other four units at the source water output. Heterotrophic plate counts were performed at baseline and twice weekly for a period of 6 weeks. One representative waterline sample was taken from each group at baseline and end-of-study to analyze changes in biofilm status using scanning electron microscopy. Waterlines not previously contaminated with biofilms did not show organization of biofilm matrix in units equipped with IRSWC. Constantly present low levels of iodine, demonstrated some disruption of biofilms in waterlines already contaminated with mature biofilms. All groups showed contamination levels < 500 cfu/ml (colony forming units per milliliter) consistent with the CDC and ADA guidelines. In this 6 weeks study, IRSWC equipped waterlines showed disruption of established biofilms, controlled formation of new biofilms in clean lines and rendered the dental treatment water < 500 cfu/ml. Point-of-use iodinated resin cartridges were also effective in controlling contamination in the dental treatment water. Dental unit water systems that are in use get contaminated with microbes and biofilms in weeks of being put into use. These biofilms contaminate the treatment water thereby putting patients and staff at risk of infection by predominantly gram-negative microbes. Biofilms in the water systems must be cleaned periodically with a strong decontaminant and the dental treatment source water needs to be modified with a low-grade antimicrobial that can preserve the water quality yet safe to humans. In this translational research study, we evaluate the effects of elemental iodine dissolved in water flowing through an iodine containing cartridge in controlling biofilm and dental treatment water contamination using a dental unit water system simulator, prior to clinical utilization.
Contamination of dental unit waterlines: assessment of three continuous water disinfection systems
Offner, Damien; Fioretti, Florence; Musset, Anne-Marie
2016-01-01
Objectives: To assess the efficacy of three continuous water disinfection systems for dental units under real conditions of dental care. Design and settings: A prospective study carried out from 45 days to 20 months on the water microbial quality of the dental units is benefited from three different systems: two chemical treatment systems (IGN EVO/Calbenium/IGN Cartridge and Sterispray) and one physical treatment system (BacTerminator). Studied items were six dental units of the Dental Medicine and Oral Surgery Center within the University Hospital of Strasbourg (HUS), France. Results and disucussion: The IGN EVO/Calbenium/IGN Cartridge and Sterispray systems showed an immediate and long-term efficacy on contaminated dental unit waterlines. However, the first system offers ergonomic advantages (automatic system, action on the water from the water supply network). The BacTerminator system took longer to be effective and was less effective than the other two. PMID:29607068
Are dentists enough aware of infectious risk associated with dental unit waterlines ?
Robert, Amélie; Bousseau, Anne; Costa, Damien; Barbot, Vanessa; Imbert, Christine
2013-07-10
Environmental conditions in DU encourage biofilm development. This biofilm may represent a risk for patients and dental staff exposed to water and aerosols generated during dental cares, particularly for immunocompromised persons. A survey was conducted on the 175 dental surgeons of the department of Vienne (France) to investigate the motivations of dental practitioners to renew their DU, their awareness levels with respect to infectious risks related to water circulating within DU, and methods used for the maintenance of DU waterlines. These dentists were only partially aware of the need for maintaining DU waterlines. For this maintaining, chemical treatments and purges of pipes were carried out by 88% and 91.5% of dentists respectively ; chemical treatments were usually on a continous mode and dentists seemed to have complete confidence in their DU supplier regarding the choice and the use of chemical treatments. Flushes were performed only once per day in most cases (63%). This survey also highlighted that dentists were not enough aware of water related infectous risk, even though 68% estimated that the development of a biofilm within DU waterlines was an actual risk. Finally, very positively, dentists strongly indicated their wish to be more informed regarding all these risks. Although these results are based on a relatively small sample, corresponding to dentists of a French department, they clearly suggest that awareness of dental surgeons is still insufficient and must be performed to permit an effective prevention of infectious risk related to DU waterlines.
Impact of a risk management plan on Legionella contamination of dental unit water.
Leoni, Erica; Dallolio, Laura; Stagni, Francesca; Sanna, Tiziana; D'Alessandro, Giovanni; Piana, Gabriela
2015-02-23
The study aimed to assess the prevalence of Legionella spp. in dental unit waterlines of a dental clinic and to verify whether the microbiological parameters used as indicators of water quality were correlated with Legionella contamination. A risk management plan was subsequently implemented in the dental health care setting, in order to verify whether the adopted disinfection protocols were effective in preventing Legionella colonization. The water delivered from syringes and turbines of 63 dental units operating in a dental clinic, was monitored for counts of the heterotrophic bacteria P. aeruginosa and Legionella spp. (22 °C and 37 °C). At baseline, output water from dental units continuously treated with disinfection products was more compliant with the recommended standards than untreated and periodically treated water. However, continuous disinfection was still not able to prevent contamination by Legionella and P. aeruginosa. Legionella was isolated from 36.4%, 24.3% and 53.3% of samples from untreated, periodically and continuously treated waterlines, respectively. The standard microbiological parameters used as indicators of water quality proved to be unreliable as predictors of the presence of Legionella, whose source was identified as the tap water used to supply the dental units. The adoption of control measures, including the use of deionized water in supplying the dental unit waterlines and the application of a combined protocol of continuous and periodic disinfection, with different active products for the different devices, resulted in good control of Legionella contamination. The efficacy of the measures adopted was mainly linked to the strict adherence to the planned protocols, which placed particular stress on staff training and ongoing environmental monitoring.
46 CFR 174.085 - Flooding on column stabilized units.
Code of Federal Regulations, 2011 CFR
2011-10-01
... the unit, and within 5 feet (1.5 meters) of an outer surface of a column or footing on the periphery... into watertight compartments by horizontal watertight flats, all compartments in the column within 5 feet (1.5 meters) of the unit's waterline before damage causing flooding must be assumed to be subject...
Effects of Hydrogen Peroxide on Dental Unit Biofilms and Treatment Water Contamination
Lin, Shih-Ming; Svoboda, Kathy K.H.; Giletto, Anthony; Seibert, Jeff; Puttaiah, Raghunath
2011-01-01
Objectives: To study effects of various concentrations of hydrogen peroxide on mature waterline biofilms and in controlling planktonic (free-floating) organisms in simulated dental treatment water systems; and to study in vitro the effects of 2%, 3%, and 7% hydrogen peroxide on the removal of mature biofilms and inorganic compounds in dental waterlines. Methods: Four units of an automated dental unit water system simulation device was used for 12 weeks. All units were initially cleaned to control biofilms and inorganic deposits. H2O2 at concentrations of 1%, 2%, 3% was used weekly for periodic cleaning in three treatment group units (units 1, 2 & 3), with 0.05%, 0.15% and 0.25% H2O2 in municipal water used as irrigant respectively. The control unit (unit 4) did not have weekly cleanings and used municipal water as irrigant. Laser Scanning Confocal Microscopy and Scanning Electron Microscopy were used to study deposits on lines, and weekly heterotrophic plate counts done to study effluent water contamination. A 24 hour in vitro challenge test with 7%, 3% and 2% H2O2 on mature biofilms was conducted using harvested waterlines to study biofilm and inorganic deposit removal. Results: Heterotrophic plate counts of effluent water showed that the control unit reached contamination levels in excess of 400,000 CFU/mL while all treatment units showed contamination levels <500 CFU/mL through most of the 12 weeks. All treatment units showed varying levels of biofilm and inorganic deposit control in this short 12 week study. The in vitro challenge test showed although there was biofilm control, there was no eradication even when 7% H2O2 was used for 24 hours. Conclusions: 2% H2O2 used as a periodic cleaner, and diluted to 0.05% in municipal water for irrigation was beneficial in controlling biofilm and planktonic contamination in dental unit water systems. However, to remove well established biofilms, it may take more than 2 months when initial and multiple periodic cleanings are performed using H2O2. PMID:21228956
Mazari, Wissame; Boucherit-Otmani, Zahia; El Haci, Imad Abdelhamid; Ilahi, Amine; Boucherit, Kebir
2018-05-04
The aim of this study was to evaluate the presence of yeasts in dental chair unit waterlines (DCUWLs) and to test their ability to form biofilms. Eighteen dental waterlines were analysed by culture in liquid Sabouraud in order to allow the quantification and the purification of isolated yeasts from their internal surfaces. All isolates were identified by standard laboratory procedures, including CHROMagar Candida medium for orientation, commercial yeast identification system Api Candida, MALDI-TOF MS and DNA sequencing. To evaluate their kinetics of antifungal susceptibility during different phases of biofilm formation, these yeasts were subjected to three antifungal agents. From the 18 DCUWLs studied, 10 were altered (55.56%). Eleven strains of Candida sp. [Candida albicans (2), Candida guilliermondii (5) and Candida glabrata (4)] and two species of non-Candida; Rhodotorula spp. (1) and Trichosporon spp. (2) were identified. The majority of yeasts in planktonic form were susceptible to amphotericin B, caspofungin and voriconazole, except C. albicans was resistant to voriconazole. In the biofilm form, caspofungin was the most effective antifungal agent for all isolated strains. For the other antifungal agents, sessile cells were resistant. Several types of yeasts were identified; the most frequently isolated genus was Candida. The majority of these yeasts had the ability to form biofilms and resisted antifungal agents used in this study. © 2018 FDI World Dental Federation.
Topographic mapping on large-scale tidal flats with an iterative approach on the waterline method
NASA Astrophysics Data System (ADS)
Kang, Yanyan; Ding, Xianrong; Xu, Fan; Zhang, Changkuan; Ge, Xiaoping
2017-05-01
Tidal flats, which are both a natural ecosystem and a type of landscape, are of significant importance to ecosystem function and land resource potential. Morphologic monitoring of tidal flats has become increasingly important with respect to achieving sustainable development targets. Remote sensing is an established technique for the measurement of topography over tidal flats; of the available methods, the waterline method is particularly effective for constructing a digital elevation model (DEM) of intertidal areas. However, application of the waterline method is more limited in large-scale, shifting tidal flats areas, where the tides are not synchronized and the waterline is not a quasi-contour line. For this study, a topographical map of the intertidal regions within the Radial Sand Ridges (RSR) along the Jiangsu Coast, China, was generated using an iterative approach on the waterline method. A series of 21 multi-temporal satellite images (18 HJ-1A/B CCD and three Landsat TM/OLI) of the RSR area collected at different water levels within a five month period (31 December 2013-28 May 2014) was used to extract waterlines based on feature extraction techniques and artificial further modification. These 'remotely-sensed waterlines' were combined with the corresponding water levels from the 'model waterlines' simulated by a hydrodynamic model with an initial generalized DEM of exposed tidal flats. Based on the 21 heighted 'remotely-sensed waterlines', a DEM was constructed using the ANUDEM interpolation method. Using this new DEM as the input data, it was re-entered into the hydrodynamic model, and a new round of water level assignment of waterlines was performed. A third and final output DEM was generated covering an area of approximately 1900 km2 of tidal flats in the RSR. The water level simulation accuracy of the hydrodynamic model was within 0.15 m based on five real-time tide stations, and the height accuracy (root mean square error) of the final DEM was 0.182 m based on six transects of measured data. This study aimed at construction of an accurate DEM for a large-scale, high-variable zone within a short timespan based on an iterative way of the waterline method.
Waterline Erosion Control Essential To Streambank Rehabilitation
Dean H. Urie
1967-01-01
Tests of streambank erosion control measures on three Michigan streams have shown the key role of waterline stabilization. After undercutting was stopped, the upper banks were revegetated in 1 to 5 years depending on treatment. Without waterline control, all revegetation efforts were ineffective.
NASA Astrophysics Data System (ADS)
Zheng, Zongsheng; Zhou, Yunxuan; Jiang, Xuezhong
2007-06-01
Ground survey is restricted by the difficulty of access to wide-range and dynamic salt marsh. Waterline method and hydrodynamic model were investigated to construct Digital Elevation Model (DEM) at Jiudunasha Shoals. A series of waterlines were extracted from multi-temporal remotely sensing images collected over the period of 2000-2004. The assignment of an elevation to each waterline at the satellite overpass was performed according to hydrodynamic model. The corrected waterlines labeled elevations were used to construct Triangulated Irregular Networks (TINs). Then an interpolation for each grid elevation was performed in accordance with the associated triangle. This initial DEM, produced using the corrected waterline set, was then used to refine the topography in the intertidal zone, and the model was re-run to produce improved water levels and a new DEM. This procedure was iterated by comparing modeled and actual waterlines until no further improvement occurred. Three DEMs of different intervals were built by this approach and were compared to evaluate the effect of Deep Water Channel Project (DWCP) at the north of Jiuduansha Island. Waterline method combined with numerical model, is an effective tool for constructing digital elevation model of mudflats. The result can provide invaluable information for coastal land use and engineer construction.
Identification of Exophiala mesophila Isolated from Treated Dental Unit Waterlines
Porteous, N. B.; Grooters, A. M.; Redding, S. W.; Thompson, E. H.; Rinaldi, M. G.; De Hoog, G. S.; Sutton, D. A.
2003-01-01
Members of the genus Exophiala are often difficult to identify to the species level because of their variable morphological appearances. This paper describes the methods used to identify Exophiala mesophila and provides salient differential features for distinguishing other mesophilic members of the genus. PMID:12904410
NASA Astrophysics Data System (ADS)
Wu, D.; Du, Y.; Su, F.; Huang, W.; Zhang, L.
2018-04-01
The topographic measurement of muddy tidal flat is restricted by the difficulty of access to the complex, wide-range and dynamic tidal conditions. Then the waterline detection method (WDM) has the potential to investigate the morph-dynamics quantitatively by utilizing large archives of satellite images. The study explores the potential for using WDM with BJ-1 small satellite images to construct a digital elevation model (DEM) of a wide and grading mudflat. Three major conclusions of the study are as follows: (1) A new intelligent correlating model of waterline detection considering different tidal stages and local geographic conditions was explored. With this correlative algorithm waterline detection model, a series of waterlines were extracted from multi-temporal remotely sensing images collected over the period of a year. The model proved to detect waterlines more efficiently and exactly. (2) The spatial structure of elevation superimposing on the points of waterlines was firstly constructed and a more accurate hydrodynamic ocean tide grid model was used. By the newly constructed abnormal hydrology evaluation model, a more reasonable and reliable set of waterline points was acquired to construct a smoother TIN and GRID DEM. (3) DEM maps of Bohai Bay, with a spatial resolution of about 30 m and height accuracy of about 0.35 m considering LiDAR and 0.19 m considering RTK surveying were constructed over an area of about 266 km2. Results show that remote sensing research in extremely turbid estuaries and tidal areas is possible and is an effective tool for monitoring the tidal flats.
46 CFR 45.77 - Salt water freeboard.
Code of Federal Regulations, 2011 CFR
2011-10-01
... mark is obtained by the formula: Addition=Δ/41T where: Δ=displacement in fresh water, in tons of 2,240... summer load waterline. (b) When the displacement at the summer load waterline cannot be certified, the...
46 CFR 45.77 - Salt water freeboard.
Code of Federal Regulations, 2014 CFR
2014-10-01
... mark is obtained by the formula: Addition=Δ/41T where: Δ=displacement in fresh water, in tons of 2,240... summer load waterline. (b) When the displacement at the summer load waterline cannot be certified, the...
46 CFR 45.77 - Salt water freeboard.
Code of Federal Regulations, 2012 CFR
2012-10-01
... mark is obtained by the formula: Addition=Δ/41T where: Δ=displacement in fresh water, in tons of 2,240... summer load waterline. (b) When the displacement at the summer load waterline cannot be certified, the...
46 CFR 45.77 - Salt water freeboard.
Code of Federal Regulations, 2013 CFR
2013-10-01
... mark is obtained by the formula: Addition=Δ/41T where: Δ=displacement in fresh water, in tons of 2,240... summer load waterline. (b) When the displacement at the summer load waterline cannot be certified, the...
46 CFR 45.77 - Salt water freeboard.
Code of Federal Regulations, 2010 CFR
2010-10-01
... mark is obtained by the formula: Addition=Δ/41T where: Δ=displacement in fresh water, in tons of 2,240... summer load waterline. (b) When the displacement at the summer load waterline cannot be certified, the...
46 CFR 172.245 - Survival conditions.
Code of Federal Regulations, 2011 CFR
2011-10-01
... stage of flooding: (a) Final waterline. The final waterline, in the final condition of sinkage, heel... nonopening type; (7) Retractable inflatable seal; or (8) Guillotine door. (b) Heel angle. The maximum angle of heel must not exceed 15 degrees, except that this angle may be increased to 17 degrees if no deck...
46 CFR 172.245 - Survival conditions.
Code of Federal Regulations, 2010 CFR
2010-10-01
... stage of flooding: (a) Final waterline. The final waterline, in the final condition of sinkage, heel... nonopening type; (7) Retractable inflatable seal; or (8) Guillotine door. (b) Heel angle. The maximum angle of heel must not exceed 15 degrees, except that this angle may be increased to 17 degrees if no deck...
Code of Federal Regulations, 2013 CFR
2013-10-01
... weather deck extending no more than one-half of the vessel's length over deck (LOD) measured over the weather deck. (b) Deepest subdivision load line means the waterline that corresponds to the deepest draft... tangent to the waterline. (g) Flush deck means a continuous weather deck located at the uppermost sheer...
Code of Federal Regulations, 2010 CFR
2010-10-01
... weather deck extending no more than one-half of the vessel's length over deck (LOD) measured over the weather deck. (b) Deepest subdivision load line means the waterline that corresponds to the deepest draft... tangent to the waterline. (g) Flush deck means a continuous weather deck located at the uppermost sheer...
Vincent, Antony T; Charette, Steve J; Barbeau, Jean
2018-05-01
The Gram-negative bacterium Pseudomonas aeruginosa is found in several habitats, both natural and human-made, and is particularly known for its recurrent presence as a pathogen in the lungs of patients suffering from cystic fibrosis, a genetic disease. Given its clinical importance, several major studies have investigated the genomic adaptation of P. aeruginosa in lungs and its transition as acute infections become chronic. However, our knowledge about the diversity and adaptation of the P. aeruginosa genome to non-clinical environments is still fragmentary, in part due to the lack of accurate reference genomes of strains from the numerous environments colonized by the bacterium. Here, we used PacBio long-read technology to sequence the genome of PPF-1, a strain of P. aeruginosa isolated from a dental unit waterline. Generating this closed genome was an opportunity to investigate genomic features that are difficult to accurately study in a draft genome (contigs state). It was possible to shed light on putative genomic islands, some shared with other reference genomes, new prophages, and the complete content of insertion sequences. In addition, four different group II introns were also found, including two characterized here and not listed in the specialized group II intron database.
Code of Federal Regulations, 2012 CFR
2012-10-01
... are allowed for CNG: (1) The storage locker or housing access opening need not be in the top. (2) The locker or housing need not be above the waterline. (h) The following variances from NFPA 302 are allowed: (1) The storage locker or housing for CNG tank installations need not be above the waterline as...
Code of Federal Regulations, 2011 CFR
2011-10-01
... are allowed for CNG: (1) The storage locker or housing access opening need not be in the top. (2) The locker or housing need not be above the waterline. (h) The following variances from NFPA 302 are allowed: (1) The storage locker or housing for CNG tank installations need not be above the waterline as...
Code of Federal Regulations, 2013 CFR
2013-10-01
... are allowed for CNG: (1) The storage locker or housing access opening need not be in the top. (2) The locker or housing need not be above the waterline. (h) The following variances from NFPA 302 are allowed: (1) The storage locker or housing for CNG tank installations need not be above the waterline as...
Code of Federal Regulations, 2010 CFR
2010-10-01
... are allowed for CNG: (1) The storage locker or housing access opening need not be in the top. (2) The locker or housing need not be above the waterline. (h) The following variances from NFPA 302 are allowed: (1) The storage locker or housing for CNG tank installations need not be above the waterline as...
46 CFR 133.150 - Survival craft launching and recovery arrangements: General.
Code of Federal Regulations, 2012 CFR
2012-10-01
... a position on deck less than 4.5 meters (14.75 feet) above the waterline in the lightest seagoing... can be boarded from a position on deck less than 4.5 meters (14.75 feet) above the waterline in the... launching appliance must not depend on any means other than gravity or stored mechanical power, independent...
46 CFR 133.150 - Survival craft launching and recovery arrangements: General.
Code of Federal Regulations, 2014 CFR
2014-10-01
... a position on deck less than 4.5 meters (14.75 feet) above the waterline in the lightest seagoing... can be boarded from a position on deck less than 4.5 meters (14.75 feet) above the waterline in the... launching appliance must not depend on any means other than gravity or stored mechanical power, independent...
Diversity and distribution of epiphytic bromeliads in a Brazilian subtropical mangrove.
Sousa, Mariana M DE; Colpo, Karine D
2017-01-01
It is not unusual to find epiphytic bromeliads in mangroves, but most studies on mangrove vegetation do not record their presence. This study aimed to evaluate the diversity and distribution of epiphytic bromeliads in a subtropical mangrove. The richness, abundance and life form (atmospheric and tank) of bromeliads were recorded and compared among host tree species and waterline proximity. The effects of diameter and height of host trees on the abundance of bromeliads were also assessed. The mangrove was composed of Avicennia schaueriana, Laguncularia racemosa and Rhizophora mangle. We recorded seven bromeliad species of the genera Tillandsia and Vriesea. The waterline proximity did not affect the abundance or diversity of bromeliads, but atmospheric forms were predominant near the waterline, whereas tank bromeliads were more frequent in the interior of the mangrove. The three mangrove species hosted bromeliads, but L. racemosa was the preferred host. The species composition showed that the distribution of bromeliads is more related to the host species than to the distance from the waterline. Bromeliad abundance increased with tree size. Bromeliads can be biological indicators of ecosystem health; therefore, inventories and host tree preferences are necessary knowledge for an adequate management of sensitive ecosystems as mangroves.
NASA Technical Reports Server (NTRS)
1992-01-01
The Floatron water purifier combines two space technologies - ionization for water purification and solar electric power generation. The water purification process involves introducing ionized minerals that kill microorganisms like algae and bacteria. The 12 inch unit floats in a pool while its solar panel collects sunlight that is converted to electricity. The resulting current energizes a specially alloyed mineral electrode below the waterline, causing release of metallic ions into the water. The electrode is the only part that needs replacing, and water purified by the system falls within EPA drinking water standards.
Microbial diversity in dental unit waterlines.
Lisboa, Guacyra M; Lisboa, Yves R M; Pinheiro, Telma M L; Stegun, Roberto C; da Silva-Filho, Eurípedes A
2014-01-01
Dental health care providers and patients are exposed during ongoing work to contamination by the water used in the dental units, due to accidental swallowing or aspiration of the sprays generated by the high-speed handpiece and the threeway syringe. This study evaluated the quality of water in dental units in the public dental care system of Maceio, Alagoas, Brazil, by conducting analyses of contamination by total coliforms, E.Coli, heterotrophic bacteria and filamentous fungi. We collected 200 mL of water at 5 sites in 6 dental offices of the Department of Health located in different parts of the city. A total 212 isolates and 16 genera of filamentous fungi were identified in the water collected from the dental units. Total coliforms indicated that the water used in dental units was not appropriate for human consumption. The high levels of contamination found in this study showed that water was a potential source of cross-infection.
Nonlinear optimization method of ship floating condition calculation in wave based on vector
NASA Astrophysics Data System (ADS)
Ding, Ning; Yu, Jian-xing
2014-08-01
Ship floating condition in regular waves is calculated. New equations controlling any ship's floating condition are proposed by use of the vector operation. This form is a nonlinear optimization problem which can be solved using the penalty function method with constant coefficients. And the solving process is accelerated by dichotomy. During the solving process, the ship's displacement and buoyant centre have been calculated by the integration of the ship surface according to the waterline. The ship surface is described using an accumulative chord length theory in order to determine the displacement, the buoyancy center and the waterline. The draught forming the waterline at each station can be found out by calculating the intersection of the ship surface and the wave surface. The results of an example indicate that this method is exact and efficient. It can calculate the ship floating condition in regular waves as well as simplify the calculation and improve the computational efficiency and the precision of results.
Simple analytical relations for ship bow waves
NASA Astrophysics Data System (ADS)
Noblesse, Francis; Delhommeau, G.?Rard; Guilbaud, Michel; Hendrix, Dane; Yang, Chi
Simple analytical relations for the bow wave generated by a ship in steady motion are given. Specifically, simple expressions that define the height of a ship bow wave, the distance between the ship stem and the crest of the bow wave, the rise of water at the stem, and the bow wave profile, explicitly and without calculations, in terms of the ship speed, draught, and waterline entrance angle, are given. Another result is a simple criterion that predicts, also directly and without calculations, when a ship in steady motion cannot generate a steady bow wave. This unsteady-flow criterion predicts that a ship with a sufficiently fine waterline, specifically with waterline entrance angle 2, may generate a steady bow wave at any speed. However, a ship with a fuller waterline (25E) can only generate a steady bow wave if the ship speed is higher than a critical speed, defined in terms of αE by a simple relation. No alternative criterion for predicting when a ship in steady motion does not generate a steady bow wave appears to exist. A simple expression for the height of an unsteady ship bow wave is also given. In spite of their remarkable simplicity, the relations for ship bow waves obtained in the study (using only rudimentary physical and mathematical considerations) are consistent with experimental measurements for a number of hull forms having non-bulbous wedge-shaped bows with small flare angle, and with the authors' measurements and observations for a rectangular flat plate towed at a yaw angle.
NASA Astrophysics Data System (ADS)
Zhang, Yuanyuan; Gao, Zhiqiang; Liu, Xiangyang; Xu, Ning; Liu, Chaoshun; Gao, Wei
2016-09-01
Reclamation caused a significant dynamic change in the coastal zone, the tidal flat zone is an unstable reserve land resource, it has important significance for its research. In order to realize the efficient extraction of the tidal flat area information, this paper takes Rudong County in Jiangsu Province as the research area, using the HJ1A/1B images as the data source, on the basis of previous research experience and literature review, the paper chooses the method of object-oriented classification as a semi-automatic extraction method to generate waterlines. Then waterlines are analyzed by DSAS software to obtain tide points, automatic extraction of outer boundary points are followed under the use of Python to determine the extent of tidal flats in 2014 of Rudong County, the extraction area was 55182hm2, the confusion matrix is used to verify the accuracy and the result shows that the kappa coefficient is 0.945. The method could improve deficiencies of previous studies and its available free nature on the Internet makes a generalization.
In-Line Filtration Improves Hygiene and Reduces Expense
NASA Technical Reports Server (NTRS)
2008-01-01
MRLB International Inc., of Fergus Falls, Minnesota, designed the DentaPure waterline purification cartridge using water purification research conducted by Umpqua Research Company, of Myrtle Creek, Oregon, as part of SBIR contracts from Johnson Space Center. Various models now address a variety of needs, and are used in dental offices and dental schools across the country. Currently the only waterline system recognized by the FDA as a medical device which meets all known standards and by the U.S. Environmental Protection Agency (EPA) as an antimicrobial device, DentaPure has also been utilized by the U.S. Air Force.
Instantaneous Coastline Extraction from LIDAR Point Cloud and High Resolution Remote Sensing Imagery
NASA Astrophysics Data System (ADS)
Li, Y.; Zhoing, L.; Lai, Z.; Gan, Z.
2018-04-01
A new method was proposed for instantaneous waterline extraction in this paper, which combines point cloud geometry features and image spectral characteristics of the coastal zone. The proposed method consists of follow steps: Mean Shift algorithm is used to segment the coastal zone of high resolution remote sensing images into small regions containing semantic information;Region features are extracted by integrating LiDAR data and the surface area of the image; initial waterlines are extracted by α-shape algorithm; a region growing algorithm with is taking into coastline refinement, with a growth rule integrating the intensity and topography of LiDAR data; moothing the coastline. Experiments are conducted to demonstrate the efficiency of the proposed method.
Technical product bulletin: this surface washing agent is for oil spill cleanups on beaches, rocks, piers, bilges, decks, waterline scum, rigs, platforms, tanks, barges engine rooms, machinery, and grease traps. Pre-treatment/soaking may be needed.
46 CFR 174.320 - Damage survival.
Code of Federal Regulations, 2010 CFR
2010-10-01
... angle of heel in each stage of flooding must not exceed 30 degrees or the angle of downflooding whichever is less. (b) The final waterline, taking into account sinkage, heel, and trim, must be below the...
46 CFR 174.320 - Damage survival.
Code of Federal Regulations, 2011 CFR
2011-10-01
... angle of heel in each stage of flooding must not exceed 30 degrees or the angle of downflooding whichever is less. (b) The final waterline, taking into account sinkage, heel, and trim, must be below the...
Aprea, Luigi; Cannova, Lucia; Firenze, Alberto; Bivona, Maria S; Amodio, Emanuele; Romano, Nino
2010-12-01
Legionella pneumophila and Pseudomonas aeruginosa are common colonizers of water environments, particularly dental unit waterlines. The aim of this study was to assess whether the technical, functional and structural characteristics of dental units can influence the presence and the levels of opportunistic pathogens. Overall, 42 water samples were collected from dental units in a teaching hospital in Palermo, Italy, including 21 samples from the 21 taps supplied by the municipal water distribution system and 21 samples from oral rinsing cups at 21 dental units. L. pneumophila was present in 16 out of 21 water samples (76.2%) from dental units, and the median concentration was higher in samples from oral rinsing cups than in those from taps (P < 0.001). P. aeruginosa was equally distributed in water samples collected from oral rinsing cups and from taps. Some characteristics of dental units (age, number of chairs per room, number of patients per day and water temperature) were slightly associated with the presence of P. aeruginosa, but not with contamination by L. pneumophila. Our experience suggests that L. pneumophila is frequently detected in dental units, as reported in previous studies, whereas P. aeruginosa is not a frequent contaminant. As a consequence, microbiological control of water quality should be routinely performed, and should include the detection of opportunistic pathogens when bacterial contamination is expected.
The Seine Net--An Overlooked Environmental Testing Tool
ERIC Educational Resources Information Center
DuPont, Sidney I.
1977-01-01
Through seining individuals, families, camps, and schools can continuingly test the aquatic life just beyond the waterline. This article discusses the process of using a seine net and what can be found in the net. (NQ)
Automatic draft reading based on image processing
NASA Astrophysics Data System (ADS)
Tsujii, Takahiro; Yoshida, Hiromi; Iiguni, Youji
2016-10-01
In marine transportation, a draft survey is a means to determine the quantity of bulk cargo. Automatic draft reading based on computer image processing has been proposed. However, the conventional draft mark segmentation may fail when the video sequence has many other regions than draft marks and a hull, and the estimated waterline is inherently higher than the true one. To solve these problems, we propose an automatic draft reading method that uses morphological operations to detect draft marks and estimate the waterline for every frame with Canny edge detection and a robust estimation. Moreover, we emulate surveyors' draft reading process for getting the understanding of a shipper and a receiver. In an experiment in a towing tank, the draft reading error of the proposed method was <1 cm, showing the advantage of the proposed method. It is also shown that accurate draft reading has been achieved in a real-world scene.
46 CFR 199.150 - Survival craft launching and recovery arrangements; general.
Code of Federal Regulations, 2012 CFR
2012-10-01
... be boarded from a position on deck less than 4.5 meters (14.75 feet) above the waterline with the...) A launching appliance must not depend on any means other than gravity or stored mechanical power...
46 CFR 199.150 - Survival craft launching and recovery arrangements; general.
Code of Federal Regulations, 2014 CFR
2014-10-01
... be boarded from a position on deck less than 4.5 meters (14.75 feet) above the waterline with the...) A launching appliance must not depend on any means other than gravity or stored mechanical power...
DETAIL OF WATER INTAKES FOR FIREFIGHTING SYSTEM ON STARBOARD SIDE ...
DETAIL OF WATER INTAKES FOR FIREFIGHTING SYSTEM ON STARBOARD SIDE OF BOAT UNDER THE WATERLINE. ZINCS ARE ALSO ADDED HERE TO PRESERVE THE METAL. - Fireboat JOHN J. HARVEY, Pier 63, North River, New York County, NY
46 CFR 169.317 - Accommodations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... of the stem. The space must not be located totally below the deepest load waterline. (b) Bulkheads separating accommodations from machinery spaces, paint lockers, storerooms, washrooms, and toilet facilities... and Arrangement Living Spaces § 169.317 Accommodations. (a) Quarters must have sufficient fresh air...
46 CFR 169.317 - Accommodations.
Code of Federal Regulations, 2013 CFR
2013-10-01
... of the stem. The space must not be located totally below the deepest load waterline. (b) Bulkheads separating accommodations from machinery spaces, paint lockers, storerooms, washrooms, and toilet facilities... and Arrangement Living Spaces § 169.317 Accommodations. (a) Quarters must have sufficient fresh air...
46 CFR 169.317 - Accommodations.
Code of Federal Regulations, 2014 CFR
2014-10-01
... of the stem. The space must not be located totally below the deepest load waterline. (b) Bulkheads separating accommodations from machinery spaces, paint lockers, storerooms, washrooms, and toilet facilities... and Arrangement Living Spaces § 169.317 Accommodations. (a) Quarters must have sufficient fresh air...
Microbiological risk factors in dentistry. Current status of knowledge.
Szymańska, Jolanta
2005-01-01
Dentists belong to a professional group potentially exposed to harmful biological factors which most often are infectious microorganisms, less frequently - allergenic or toxic microorganisms. The fundamental routes of spreading harmful microorganisms in a dental surgery are: blood-borne, saliva-droplet, direct contact with a patient and with infected equipment, and water-droplet infections. In this paper, the current status of knowledge on microbiological hazards in a dentist's work is presented. Groups of microorganisms, such as prions, viruses, bacteria, fungi and protozoa, to which a dentist is, or may be exposed, are discussed. Epidemiological assessment of microbiological hazards in a dentist's work was performed and the basic principles of prevention formulated. Special attention was given to microflora in dental unit waterlines, and the biofilm persisting in them, as a source of occupational hazards specific for a dentist's workplace.
46 CFR 25.45-2 - Cooking systems on vessels carrying passengers for hire.
Code of Federal Regulations, 2011 CFR
2011-10-01
... allowed for CNG: (i) The storage locker or housing access opening need not be in the top. (ii) The locker...) The storage locker or housing for CNG tank installations need not be above the waterline as required...
46 CFR 25.45-2 - Cooking systems on vessels carrying passengers for hire.
Code of Federal Regulations, 2013 CFR
2013-10-01
... allowed for CNG: (i) The storage locker or housing access opening need not be in the top. (ii) The locker...) The storage locker or housing for CNG tank installations need not be above the waterline as required...
46 CFR 25.45-2 - Cooking systems on vessels carrying passengers for hire.
Code of Federal Regulations, 2010 CFR
2010-10-01
... allowed for CNG: (i) The storage locker or housing access opening need not be in the top. (ii) The locker...) The storage locker or housing for CNG tank installations need not be above the waterline as required...
46 CFR 25.45-2 - Cooking systems on vessels carrying passengers for hire.
Code of Federal Regulations, 2012 CFR
2012-10-01
... allowed for CNG: (i) The storage locker or housing access opening need not be in the top. (ii) The locker...) The storage locker or housing for CNG tank installations need not be above the waterline as required...
Code of Federal Regulations, 2014 CFR
2014-07-01
... casing having low resistance to earth; (c) A solid connection to metal waterlines having low resistance to earth; (d) A solid connection to a grounding conductor extending to a low resistance ground field... earth. ...
Code of Federal Regulations, 2012 CFR
2012-07-01
... casing having low resistance to earth; (c) A solid connection to metal waterlines having low resistance to earth; (d) A solid connection to a grounding conductor extending to a low resistance ground field... earth. ...
Code of Federal Regulations, 2013 CFR
2013-07-01
... casing having low resistance to earth; (c) A solid connection to metal waterlines having low resistance to earth; (d) A solid connection to a grounding conductor extending to a low resistance ground field... earth. ...
30 CFR 57.4261 - Shaft-station waterlines.
Code of Federal Regulations, 2010 CFR
2010-07-01
....4261 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention... located at underground shaft stations and are part of the mine's fire protection system shall have at...
Study on collision resistance characteristics of the side tanks with water inside
NASA Astrophysics Data System (ADS)
Liu, Yuxi; Hu, Jinwen; Liu, Ting; Wu, Can
2018-05-01
When we evaluate the safety performance of ships against external events, one of the most important indicator is the collision resistance to which water inside the side tanks also make some contributions because of the water effect. To further analyze the interaction mechanism, different collision velocities and side tank waterlines are set for the analysis model. Results indicate the outside shell and the inner shell of the side structure significantly enhanced the collision resistance performance to a certain extension. The water effect on the failure of the outside shell is unobvious, while, it performs a great influence on the destructive reaction force of the inner shell. When the velocity of the coming bulbous bow gradually increases, the destructive reaction forces of the outside shell and the inner shell increase with a decreasing rate. Besides, water influence the collision characteristics of the inner shell a lot when the waterlines are below the upper rib of the strong frame.
Chenier Plain Sediment Burial Pipe Measurements
NASA Technical Reports Server (NTRS)
Moeller, Chris; Gunshor, Mat; Huh, Oscar; Winch, Dale
2000-01-01
These field notes describe the logistical circumstances and field conditions experienced by the researchers, who measured the waterlines on a series of vertical pipes previously buried in shallow coastal water. The purpose of the measurements was to monitor a portion of the Gulf coast in Louisiana for erosion.
The Way Ahead For Maritime UAVS
2006-10-23
of possible contract winners including Scan Eagle, Silver Fox, Wasp, Coyote and the USMC Tier I winner Dragon Eye. Technical data for these UAVs are...Neptune’s engine and avionics are placed above the waterline and the airframe is sealed for flotation as well as providing corrosion/water intrusion
46 CFR 127.270 - Location of accommodations and pilothouse.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Section 127.270 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS... waterline. (d) No hawse pipe or chain pipe may pass through accommodations for crew members or offshore... accommodations and chain lockers, cargo spaces, or machinery spaces. (f) No sounding tubes, or vents from fuel...
46 CFR 127.270 - Location of accommodations and pilothouse.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Section 127.270 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS... waterline. (d) No hawse pipe or chain pipe may pass through accommodations for crew members or offshore... accommodations and chain lockers, cargo spaces, or machinery spaces. (f) No sounding tubes, or vents from fuel...
46 CFR 127.270 - Location of accommodations and pilothouse.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Section 127.270 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS... waterline. (d) No hawse pipe or chain pipe may pass through accommodations for crew members or offshore... accommodations and chain lockers, cargo spaces, or machinery spaces. (f) No sounding tubes, or vents from fuel...
Northern Sea Route and Icebreaking Technology
1994-06-01
waterlines at the extreme forward end, extended beam, a low stem angle with an ice-clearing forefoot , and a high flare angle below the water- line. The ice...world. Reports of protests and labor strikes , stemming from poor wages sectors of the economy. The Gross and living conditions, are common. With
The Role of Flushing Dental Waterlines for the Removal of Microbial Contaminants - MCEARD
Objectives. This study was designed to determine the role of flushing dental water lines for the removal of heterotrophic plate count bacteria, Legionella spp., and free-living protozoa. Methods. Forty dental offices were surveyed in the study. An initial sample and a sample tak...
Creative Photography - Wildlife
2016-03-25
Black skimmers fly just above the waterline as they hunt for fish at Merritt Island National Wildlife Refuge in Florida. NASA’s Kennedy Space Center shares boundaries with the refuge, which is home to more than 330 native and migratory bird species, along with 25 mammal, 117 fish, and 65 amphibian and reptile species.
46 CFR 174.015 - Intact stability.
Code of Federal Regulations, 2010 CFR
2010-10-01
... foot-degrees (4.57 meter-degrees) for ocean and Great Lakes winter service; and (2) 10 foot-degrees (3.05 meter-degrees) for lakes, bays, sounds, and Great Lakes summer service. (b) For the purpose of... centerline and waterline in calm water to the first opening that does not close watertight automatically. ...
46 CFR 127.270 - Location of accommodations and pilothouse.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Section 127.270 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS... waterline. (d) No hawse pipe or chain pipe may pass through accommodations for crew members or offshore... accommodations and chain lockers, cargo spaces, or machinery spaces. (f) No sounding tubes, or vents from fuel...
46 CFR 127.270 - Location of accommodations and pilothouse.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Section 127.270 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS... waterline. (d) No hawse pipe or chain pipe may pass through accommodations for crew members or offshore... accommodations and chain lockers, cargo spaces, or machinery spaces. (f) No sounding tubes, or vents from fuel...
46 CFR 28.510 - Definition of stability terms.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 1 2012-10-01 2012-10-01 false Definition of stability terms. 28.510 Section 28.510... FISHING INDUSTRY VESSELS Stability § 28.510 Definition of stability terms. Downflooding means the entry of... the forward side of the vessel's stem and the vessel's waterline at the vessel's deepest operating...
46 CFR 28.510 - Definition of stability terms.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 1 2011-10-01 2011-10-01 false Definition of stability terms. 28.510 Section 28.510... FISHING INDUSTRY VESSELS Stability § 28.510 Definition of stability terms. Downflooding means the entry of... the forward side of the vessel's stem and the vessel's waterline at the vessel's deepest operating...
46 CFR 28.510 - Definition of stability terms.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 1 2013-10-01 2013-10-01 false Definition of stability terms. 28.510 Section 28.510... FISHING INDUSTRY VESSELS Stability § 28.510 Definition of stability terms. Downflooding means the entry of... the forward side of the vessel's stem and the vessel's waterline at the vessel's deepest operating...
46 CFR 28.510 - Definition of stability terms.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 1 2010-10-01 2010-10-01 false Definition of stability terms. 28.510 Section 28.510... FISHING INDUSTRY VESSELS Stability § 28.510 Definition of stability terms. Downflooding means the entry of... the forward side of the vessel's stem and the vessel's waterline at the vessel's deepest operating...
46 CFR 28.510 - Definition of stability terms.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 1 2014-10-01 2014-10-01 false Definition of stability terms. 28.510 Section 28.510... FISHING INDUSTRY VESSELS Stability § 28.510 Definition of stability terms. Downflooding means the entry of... the forward side of the vessel's stem and the vessel's waterline at the vessel's deepest operating...
30 CFR 75.700-1 - Approved methods of grounding.
Code of Federal Regulations, 2012 CFR
2012-07-01
... a borehole casing having low resistance to earth; (b) A solid connection to metal waterlines having low resistance to earth; (c) A solid connection to a grounding conductor, other than the neutral... ensures that there is no difference in potential between such metallic enclosures and the earth. ...
30 CFR 75.700-1 - Approved methods of grounding.
Code of Federal Regulations, 2014 CFR
2014-07-01
... a borehole casing having low resistance to earth; (b) A solid connection to metal waterlines having low resistance to earth; (c) A solid connection to a grounding conductor, other than the neutral... ensures that there is no difference in potential between such metallic enclosures and the earth. ...
46 CFR 172.195 - Survival conditions.
Code of Federal Regulations, 2014 CFR
2014-10-01
... assumed damage if it meets the following conditions in the final stage of flooding: (a) Final waterline... of an opening through which progressive flooding may take place, such as an air pipe, or an opening... least 3.94 inches (10 cm). (3) Each submerged opening must be weathertight. (d) Progressive flooding. If...
46 CFR 172.195 - Survival conditions.
Code of Federal Regulations, 2013 CFR
2013-10-01
... assumed damage if it meets the following conditions in the final stage of flooding: (a) Final waterline... of an opening through which progressive flooding may take place, such as an air pipe, or an opening... least 3.94 inches (10 cm). (3) Each submerged opening must be weathertight. (d) Progressive flooding. If...
46 CFR 172.195 - Survival conditions.
Code of Federal Regulations, 2012 CFR
2012-10-01
... assumed damage if it meets the following conditions in the final stage of flooding: (a) Final waterline... of an opening through which progressive flooding may take place, such as an air pipe, or an opening... least 3.94 inches (10 cm). (3) Each submerged opening must be weathertight. (d) Progressive flooding. If...
Barbeau, Jean
2007-09-01
This case report highlights the risks that may be associated with amoebae in the water of a dental unit. A woman with contact lenses visited her dentist for replacement of a bridge. During the treatment, a stream of water was directed from the handpiece into her right eye. Because of subsequent pain in the eye, the patient consulted several ophthalmologists, who discovered abrasive lesions of the cornea and inflammation. Despite antibacterial and anti-inflammatory treatments, the patient"s visual acuity declined gradually over a period of several days. A microbiological examination nearly 2 months later revealed amoebae in corneal samples. A lawsuit against the dentist was initiated. Although a causal relation with the dental treatment was rejected by the judge in this case, high numbers of amoebae in the water of dental units can present a risk if a patient with pre-existing corneal lesions is splashed. According to the precautionary principle, complete evidence of risk does not have to exist to institute measures to protect individuals and society from that risk. This case reinforces the importance of having patients wear safety glasses during dental treatments and of dental personnel draining the waterlines of dental units, as recommended by the Canadian Dental Association.
30 CFR 77.700-1 - Approved methods of grounding.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Approved methods of grounding. 77.700-1 Section... COAL MINES Grounding § 77.700-1 Approved methods of grounding. Metallic sheaths, armors, and conduits... methods of grounding will be approved: (a) A solid connection to metal waterlines having low resistance to...
30 CFR 77.700-1 - Approved methods of grounding.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Approved methods of grounding. 77.700-1 Section... COAL MINES Grounding § 77.700-1 Approved methods of grounding. Metallic sheaths, armors, and conduits... methods of grounding will be approved: (a) A solid connection to metal waterlines having low resistance to...
30 CFR 77.700-1 - Approved methods of grounding.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approved methods of grounding. 77.700-1 Section... COAL MINES Grounding § 77.700-1 Approved methods of grounding. Metallic sheaths, armors, and conduits... methods of grounding will be approved: (a) A solid connection to metal waterlines having low resistance to...
46 CFR 199.230 - Stowage of survival craft.
Code of Federal Regulations, 2010 CFR
2010-10-01
... vessel of 80 meters (262 feet) in length and upwards must be stowed where the after-end of the lifeboat... height of a survival craft must take into account the vessel's escape provisions, the vessel's size, and... as practicable, not exceed 15 meters (49 feet) to the waterline when the vessel is in its lightest...
46 CFR 199.230 - Stowage of survival craft.
Code of Federal Regulations, 2011 CFR
2011-10-01
... vessel of 80 meters (262 feet) in length and upwards must be stowed where the after-end of the lifeboat... height of a survival craft must take into account the vessel's escape provisions, the vessel's size, and... as practicable, not exceed 15 meters (49 feet) to the waterline when the vessel is in its lightest...
Code of Federal Regulations, 2014 CFR
2014-10-01
... section 1.12 are allowed for CNG: (1) The storage locker or housing access opening need not be in the top; and (2) The locker or housing need not be above the waterline. (h) The following variances from NFPA 302 are allowed. (1) The storage locker or housing for CNG tank installations need not be above the...
Code of Federal Regulations, 2011 CFR
2011-10-01
... section 1.12 are allowed for CNG: (1) The storage locker or housing access opening need not be in the top; and (2) The locker or housing need not be above the waterline. (h) The following variances from NFPA 302 are allowed. (1) The storage locker or housing for CNG tank installations need not be above the...
Code of Federal Regulations, 2012 CFR
2012-10-01
... section 1.12 are allowed for CNG: (1) The storage locker or housing access opening need not be in the top; and (2) The locker or housing need not be above the waterline. (h) The following variances from NFPA 302 are allowed. (1) The storage locker or housing for CNG tank installations need not be above the...
Code of Federal Regulations, 2010 CFR
2010-10-01
... section 1.12 are allowed for CNG: (1) The storage locker or housing access opening need not be in the top; and (2) The locker or housing need not be above the waterline. (h) The following variances from NFPA 302 are allowed. (1) The storage locker or housing for CNG tank installations need not be above the...
Code of Federal Regulations, 2013 CFR
2013-10-01
... section 1.12 are allowed for CNG: (1) The storage locker or housing access opening need not be in the top; and (2) The locker or housing need not be above the waterline. (h) The following variances from NFPA 302 are allowed. (1) The storage locker or housing for CNG tank installations need not be above the...
Submarine Rescue. Mooring and Salvage Ships of the Soviet Navy,
1983-07-13
motion after they strike the surface of the water, because of which they are carried away from the ship and can no longer endanger the ship. Only four of...they have a characteristic icebreaker bow, while the others have a protruding bulb at the forefoot . Above the waterline - aside from the completely
75 FR 39926 - Deer Creek Station Energy Facility Project (DOE/EIS-0415)
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-13
... County, South Dakota, approximately 13.2 miles of new natural gas supply pipeline, a 0.75- mile.... To provide natural gas, a 10-mile natural gas pipeline would be constructed from the site to access..., and groundwater. Crossings of streams and wetlands by gas pipelines and waterlines have been minimized...
46 CFR 172.195 - Survival conditions.
Code of Federal Regulations, 2011 CFR
2011-10-01
.... The final waterline, in the final condition of sinkage, heel, and trim, must be below the lower edge...) Heel angle. The maximum angle of heel must not exceed 30 degrees. (c) Range of stability. Through an... lines may not be considered for reducing the angle of heel. Spaces joined by ducts of large cross...
46 CFR 172.195 - Survival conditions.
Code of Federal Regulations, 2010 CFR
2010-10-01
.... The final waterline, in the final condition of sinkage, heel, and trim, must be below the lower edge...) Heel angle. The maximum angle of heel must not exceed 30 degrees. (c) Range of stability. Through an... lines may not be considered for reducing the angle of heel. Spaces joined by ducts of large cross...
96. View aft, port side, from just forward of the ...
96. View aft, port side, from just forward of the mizzenmast. Cans in foreground store Fluid Film, used to protect structural steel below waterline from oxidation. Sails stored on shelving in background have since been moved to Museum Storage. - Ship BALCLUTHA, 2905 Hyde Street Pier, San Francisco, San Francisco County, CA
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 2 2012-10-01 2012-10-01 false Definitions. 69.53 Section 69.53 Shipping COAST GUARD... Convention Measurement System § 69.53 Definitions. As used in this subpart— Amidships means the midpoint of... the fore side of the stem to the axis of the rudder stock on that waterline, whichever is greater. In...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 2 2011-10-01 2011-10-01 false Definitions. 69.53 Section 69.53 Shipping COAST GUARD... Convention Measurement System § 69.53 Definitions. As used in this subpart— Amidships means the midpoint of... the fore side of the stem to the axis of the rudder stock on that waterline, whichever is greater. In...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 2 2013-10-01 2013-10-01 false Definitions. 69.53 Section 69.53 Shipping COAST GUARD... Convention Measurement System § 69.53 Definitions. As used in this subpart— Amidships means the midpoint of... the fore side of the stem to the axis of the rudder stock on that waterline, whichever is greater. In...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 2 2010-10-01 2010-10-01 false Definitions. 69.53 Section 69.53 Shipping COAST GUARD... Convention Measurement System § 69.53 Definitions. As used in this subpart— Amidships means the midpoint of... the fore side of the stem to the axis of the rudder stock on that waterline, whichever is greater. In...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 2 2014-10-01 2014-10-01 false Definitions. 69.53 Section 69.53 Shipping COAST GUARD... Convention Measurement System § 69.53 Definitions. As used in this subpart— Amidships means the midpoint of... the fore side of the stem to the axis of the rudder stock on that waterline, whichever is greater. In...
46 CFR 15.855 - Cabin watchmen and fire patrolmen.
Code of Federal Regulations, 2010 CFR
2010-10-01
... other danger. (b) On a fish processing vessel of more than 100 gross tons, there must be a suitable....400(c) of this chapter. (2) All grills, broilers, and deep-fat fryers are fitted with a grease... alarms are located in each space with a through hull fitting below the deepest load waterline, a...
46 CFR 178.340 - Stability standards for pontoon vessels on protected waters.
Code of Federal Regulations, 2011 CFR
2011-10-01
... = 2.0 feet (0.61 meters); Mw = Wind heeling moment in foot-pounds (kilogram-meters) P = Wind pressure of 7.5 pounds/square foot (36.6 kilograms/square meter); A = Area, in square feet (square meters), of the projected lateral surface of the vessel above the waterline (including each projected area of the...
46 CFR 178.340 - Stability standards for pontoon vessels on protected waters.
Code of Federal Regulations, 2014 CFR
2014-10-01
... = 2.0 feet (0.61 meters); Mw = Wind heeling moment in foot-pounds (kilogram-meters) P = Wind pressure of 7.5 pounds/square foot (36.6 kilograms/square meter); A = Area, in square feet (square meters), of the projected lateral surface of the vessel above the waterline (including each projected area of the...
46 CFR 178.340 - Stability standards for pontoon vessels on protected waters.
Code of Federal Regulations, 2012 CFR
2012-10-01
... = 2.0 feet (0.61 meters); Mw = Wind heeling moment in foot-pounds (kilogram-meters) P = Wind pressure of 7.5 pounds/square foot (36.6 kilograms/square meter); A = Area, in square feet (square meters), of the projected lateral surface of the vessel above the waterline (including each projected area of the...
46 CFR 178.340 - Stability standards for pontoon vessels on protected waters.
Code of Federal Regulations, 2013 CFR
2013-10-01
... = 2.0 feet (0.61 meters); Mw = Wind heeling moment in foot-pounds (kilogram-meters) P = Wind pressure of 7.5 pounds/square foot (36.6 kilograms/square meter); A = Area, in square feet (square meters), of the projected lateral surface of the vessel above the waterline (including each projected area of the...
46 CFR 172.150 - Survival conditions.
Code of Federal Regulations, 2010 CFR
2010-10-01
... waterline, in the final condition of sinkage, heel, and trim, must be below the lower edge of openings such.... (5) Side scuttles of the non-opening type. (b) Heel angle. (1) Except as described in paragraph (b)(2) of this section, the maximum angle of heel must not exceed 15 degrees (17 degrees if no part of the...
46 CFR 172.150 - Survival conditions.
Code of Federal Regulations, 2011 CFR
2011-10-01
... waterline, in the final condition of sinkage, heel, and trim, must be below the lower edge of openings such.... (5) Side scuttles of the non-opening type. (b) Heel angle. (1) Except as described in paragraph (b)(2) of this section, the maximum angle of heel must not exceed 15 degrees (17 degrees if no part of the...
Code of Federal Regulations, 2010 CFR
2010-10-01
... ice on each surface above the waterline of a vessel which operates north of 66°30′ North latitude or... (d) of this section, the weight of assumed ice on a vessel that operates north of 42° North but south... height of the center of gravity of the accumulated ice should be calculated according to the position of...
Code of Federal Regulations, 2014 CFR
2014-10-01
... ice on each surface above the waterline of a vessel which operates north of 66°30′ North latitude or... (d) of this section, the weight of assumed ice on a vessel that operates north of 42° North but south... height of the center of gravity of the accumulated ice should be calculated according to the position of...
Code of Federal Regulations, 2013 CFR
2013-10-01
... ice on each surface above the waterline of a vessel which operates north of 66°30′ North latitude or... (d) of this section, the weight of assumed ice on a vessel that operates north of 42° North but south... height of the center of gravity of the accumulated ice should be calculated according to the position of...
Code of Federal Regulations, 2011 CFR
2011-10-01
... ice on each surface above the waterline of a vessel which operates north of 66°30′ North latitude or... (d) of this section, the weight of assumed ice on a vessel that operates north of 42° North but south... height of the center of gravity of the accumulated ice should be calculated according to the position of...
33 CFR 165.906 - Lakeside Yacht Club in Cleveland Harbor, Cleveland, OH-regulated navigation areas.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Lakeside Yacht Club in Cleveland... Guard District § 165.906 Lakeside Yacht Club in Cleveland Harbor, Cleveland, OH—regulated navigation... portion of the vessel extending above the waterline. All of these areas are inside the “Lakeside Yacht...
33 CFR 165.906 - Lakeside Yacht Club in Cleveland Harbor, Cleveland, OH-regulated navigation areas.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Lakeside Yacht Club in Cleveland... Guard District § 165.906 Lakeside Yacht Club in Cleveland Harbor, Cleveland, OH—regulated navigation... portion of the vessel extending above the waterline. All of these areas are inside the “Lakeside Yacht...
Mechanized scaling with ultrasonics: Perils and proactive measures
Paramashivaiah, Rashmi; Prabhuji, M. L. V
2013-01-01
Mechanized scaling for plaque removal is a routine procedure in the practice of periodontics. Though it appears innocuous by itself, there are retinues of hazards associated with it on various organ systems in the body. Some of these unwanted effects and measures to avoid or ameliorate the same are elaborated here. Exposure to ultrasonic scaling is inevitable before any other treatment procedure. Aerosol contamination, vibrational hazards, thermal effects on the dental pulp, altered vascular dynamics, disruption in electromagnetic device, diminished hearing and dental unit waterline contamination are some of the probable off-shoots a patient has to bear. Uses of barrier devices, proper attention to usage of equipment, protection for ear and water treatment are few of solutions for the same. Though documented evidence for the existence of all effects is lacking, it is never the less significant for the overall safety of the patient. A conscientious clinician should therefore inculcate the available steps to overcome the hazards of ultrasonic scaling. PMID:24174718
Crusius, John; Pieters, R.; Leung, A.; Whittle, P.; Pedersen, T.; Lawrence, G.; McNee, J.J.
2003-01-01
Pit lakes are becoming increasingly common in North America as well as in the rest of the world. They are created as openpit mines fill passively with ground water and surface inflows on cessation of mining activity. In many instances, the water quality in these pit lakes does not meet regulatory requirements due to a number of influences. The most important are the oxidation of sulfide minerals and the associated release of acid and metals and the flushing of soluble metals during pit filling. Examples of pit lakes with severe water-quality problems include the Berkeley Pit lake (Butte, MT) and the Liberty Pit lake (Nevada), whose waters are characterized by a pH near 3 and Cu concentrations as high as ~150 mg/L (Miller et al., 1996; Davis and Eary, 1997). The importance of the problem can be seen in the fact that some of these sites in the United States are Superfund sites.
2004-07-28
width of the API will n&nQW to 16 meters and thi~ encompasses the entire IU’ea be~ Coast Rd and the·Union Pacific right-of-wa:r boundary as defined in...Salvia mellifera Black sage * * Salvia spathacea Hummingbird sage * Sambucchus mexicana Mexican elderbern· * * Scrophularia atrata 2.3A Black
USDA-ARS?s Scientific Manuscript database
An in vitro experiment was conducted to understand the nature of biofilm growth on polyvinyl chloride (PVC) surface when exposed to sub optimal quality microbial water (> 4 log10 cfu/ml) obtained from poultry drinking water source mimicking water in waterlines during the first week of poultry broodi...
33 CFR 169.5 - How are terms used in this part defined?
Code of Federal Regulations, 2011 CFR
2011-07-01
... § 169.15). Gross tons means vessel tonnage measured in accordance with the method utilized by the flag... water and is capable of a maximum speed equal to or exceeding V=3.7×displ .1667, where “V” is the maximum speed and “displ” is the vessel displacement corresponding to the design waterline in cubic meters...
33 CFR 169.5 - How are terms used in this part defined?
Code of Federal Regulations, 2012 CFR
2012-07-01
... § 169.15). Gross tons means vessel tonnage measured in accordance with the method utilized by the flag... water and is capable of a maximum speed equal to or exceeding V=3.7×displ .1667, where “V” is the maximum speed and “displ” is the vessel displacement corresponding to the design waterline in cubic meters...
33 CFR 169.5 - How are terms used in this part defined?
Code of Federal Regulations, 2013 CFR
2013-07-01
... § 169.15). Gross tons means vessel tonnage measured in accordance with the method utilized by the flag... water and is capable of a maximum speed equal to or exceeding V=3.7×displ .1667, where “V” is the maximum speed and “displ” is the vessel displacement corresponding to the design waterline in cubic meters...
33 CFR 169.5 - How are terms used in this part defined?
Code of Federal Regulations, 2014 CFR
2014-07-01
... § 169.15). Gross tons means vessel tonnage measured in accordance with the method utilized by the flag... water and is capable of a maximum speed equal to or exceeding V=3.7×displ .1667, where “V” is the maximum speed and “displ” is the vessel displacement corresponding to the design waterline in cubic meters...
46 CFR 133.150 - Survival craft launching and recovery arrangements: General.
Code of Federal Regulations, 2010 CFR
2010-10-01
... craft that can be boarded from a position on deck less than 4.5 meters (14.75 feet) above the waterline...); (2) Those survival craft that can be boarded from a position on deck less than 4.5 meters (14.75 feet... gravity or stored mechanical power, independent of the OSV's power supplies, to launch the survival craft...
46 CFR 133.150 - Survival craft launching and recovery arrangements: General.
Code of Federal Regulations, 2011 CFR
2011-10-01
... craft that can be boarded from a position on deck less than 4.5 meters (14.75 feet) above the waterline...); (2) Those survival craft that can be boarded from a position on deck less than 4.5 meters (14.75 feet... gravity or stored mechanical power, independent of the OSV's power supplies, to launch the survival craft...
2014-04-03
CAPE CANAVERAL, Fla. – A manatee raises its eyes and nose above the waterline in a creek at NASA's Kennedy Space Center in Florida. The center shares a boundary with the Merritt Island National Wildlife Refuge, which encompasses 140,000 acres that provide a habitat for more than 330 species of birds, 31 mammals, 117 fishes, and 65 amphibians and reptiles. Photo credit: NASA/Daniel Casper
NASA Astrophysics Data System (ADS)
White, S. M.; Madsen, E.
2013-12-01
Inundation of marsh surfaces by tidal creek flooding has implications for the headward erosion of salt marsh creeks, effect of rising sea levels, biological zonation, and marsh ecosystem services. The hydroperiod; as the frequency, duration, depth and flux of water across the marsh surface; is a key factor in salt marsh ecology, but remains poorly understood due to lack of data at spatial scales relevant to tracking the spatial movement of water across the marsh. This study examines how hydroperiod, drainage networks, and tidal creek geomorphology on the vegetation at Crab Haul Creek. Crab Haul Creek is the farthest landward tidal basin in North Inlet, a bar-built estuary in South Carolina. This study measures the hydroperiod in the headwaters Crab Haul Creek with normal and near-IR photos from a helium balloon Helikite at 75-100 m altitude. Photos provide detail necessary to resolve the waterline and delineate the hydroperiod during half tidal cycles by capturing the waterline hourly from the headwaters to a piezometer transect 260 meters north. The Helikite is an ideal instrument for local investigations of surface hydrology due to its maneuverability, low cost, ability to remain aloft for extended time over a fixed point, and ability to capture high-resolution images. Photographs taken from aircraft do not provide the detail necessary to determine the waterline on the marsh surface. The near-IR images make the waterline more distinct by increasing the difference between wet and dry ground. In the headwaters of Crab Haul Creek, individual crab burrows are detected by automated image classification and the number of crab burrows and their spatial density is tracked from January-August. Crab burrows are associated with the unvegetated region at the creek head, and we relate their change over time to the propagation of the creek farther into the tidal basin. Plant zonation is influenced by the hydroperiod, but also may be affected by salinity, water table depth, and soil water content. These other factors are all directly affected by the hydroperiod, creating a complex system of feedbacks. Inundation frequencies show a pronounced relationship to zonation. Creek bank height and the hydroperiod have a curvilinear relationship at low bank heights such that small decreases in creek bank height can result in large increases in inundation frequency. Biological zonation is not simply a result of bank height and inundation frequency, other contributing factors include species competition, adaptability, and groundwater flow. Vegetation patterns delineated by a ground-based GPS survey and image classification from the aerial photos show that not all changes in eco-zonation are a direct function of elevation. Some asymmetry across the creek is observed in plant habitat, and eliminating topography (and thereby tidal inundation) as a factor, we attribute the remaining variability to groundwater flow.
Thermal Effects on the "Ice-Cube Puzzle"
ERIC Educational Resources Information Center
Lima, F. M. S.; Monteiro, F. F.
2012-01-01
When an ice cube floating on water in a container melts, it is said in some textbooks that the water level does not change. However, as pointed out by Lan in a recent work, when the buoyant force from a less dense fluid resting above the waterline is taken into account, one should expect a detectable "increase" in the volume of water. Here in this…
Day of Launch Profile Selection for Pad Abort Guidance
NASA Technical Reports Server (NTRS)
Whitley, Ryan J.
2010-01-01
A day of launch selection approach that involves choosing from an array of pitch profiles of varying loft was analyzed with the purpose of reducing the risk of a land landing failure during a pad abort. It was determined that selecting from three pitch profiles can reduce the number of waterline abort performance requirement failures approximately in half without compromising other performance metrics.
NASA Astrophysics Data System (ADS)
Shang, Kun; Zhao, Dong; Gan, Fuping; Xiao, Chenchao
2016-04-01
Many wetlands in the world have degraded rapidly in recent years, especially in China. The Yellow River Delta (YRD) is one of the largest deltas in China. The YRD Nature Reserve is one of China's most complete, broadest, and youngest wetland ecological systems in the warm-temperate zone. Most previous studies have placed particular emphasis on ecological environment or landscape of the YRD based on the distribution of wetlands. In recent years, with the rapid development of the city of Dongying, located in the YRD, the impacts of human activities are increasingly significant, so that monitoring changes in the wetlands has become especially important. In this research, we applied an improved Support Vector Machine (SVM) approach to wetland classification based on feature band set construction and optimization using seven Landsat images. By extracting waterlines, classifying wetlands and deriving landscape parameters, we have achieved high-frequency comprehensive monitoring of the wetlands in the YRD over a relatively long period. It offers a better estimate of wetland change trends than certain previous studies. From 1987 to 2010, the natural waterline primarily experienced erosion due to precipitation abnormalities, as well as coastal exploitation, as the co-analyzed meteorological data suggest. Meanwhile, the artificial waterline barely changed. The wetland area decreased rapidly from approximately 4,607 km2 to 2,714 km2 between 1987 and 2000. Ecological resilience and landscape diversity also decreased significantly during this period. The major impact factors were most likely urbanization, population expansion and the exploitation of the wetlands. After 2000, ecological resilience exhibited a positive trend. However, because newly built aquatic farms and salt works caused serious damages and threatened the natural beach landscape, the landscape fragmentation of muddy and sandy beaches increased after 2000. According to the results, more effective policies and laws for wetland protection are urgently needed, and the water sources of these wetlands should be guaranteed in the future. In particular, there is an urgent need to establish a complete dynamic monitoring system of the land use/cover change in the YRD.
Sacchetti, Rossella; Baldissarri, Augusto; De Luca, Giovanna; Lucca, Paola; Stampi, Serena; Zanetti, Franca
2006-01-01
The investigation was carried out by evaluating the microbiological characteristics of the water before and after treatment with Er:YAG laser and turbine. The study was carried out in 2 dental surgeries. In both cases the laser and dental units were served by two independent circuits, fed by the same potable tap water. Samples were taken from the water supplying and the water leaving the turbine and laser before and after treatment on the same patient. Total heterotrophic plate count was measured at 36 degrees C and at 22 degrees C, and the presence of Staphylococcus species and non-fermenting Gram negative bacteria was investigated. Bacterial contamination was found within the circuit, especially in the laser device. Pseudomonas aeruginosa was detected in only 1 sample of supply water, in 11.1 % and in 19.4 % of the samples from the turbine and the laser respectively. No evidence of Staphylococcus aureus was found. The contamination of supply water was low, whereas that of the water leaving the handpieces of the 2 devices was high, especially in the laser. Attention should be paid to the control of the water leaving laser devices, given the increasingly wide use of such instruments in dental treatment exposed to risk of infection.
Legionella contamination in the water system of hospital dental settings.
Veronesi, Licia; Capobianco, Emanuela; Affanni, Paola; Pizzi, Silvia; Vitali, Pietro; Tanzi, Maria Luisa
2007-08-01
Among hospital facilities the dental unit is an environment that is at major risk of Legionella due to equipment such as the air/water syringe, the turbine, the micromotor and the scaler which generate potentially harmful aerosols that may to be a source of exposure to Legionella spp. particularly in immunodeficient patients, and those affected by chronic diseases, and also in dental personnel. Therefore, an examination of the extent of Legionella spp. contamination in the dental chairs waterlines and the incoming water supply of some public dental units is the subject of the present study. From February 2002 to March 2004, a total of 208 water samples were collected: 160 samples from the water supply of 4 dental chair and 48 samples from the cold incoming tap water of 2 units. Legionella spp. was detected in 46 samples (22.1% ): 19 of them (41.3% of Legionella spp.; 9.1% of the total) were Legionella pneumophila; Pseudomonas aeruginosa was detected in 86 samples (41.4%) and both microorganisms were detected in 2 samples (0.96%). Our results show a microbiological condition in dental settings, that is not at all satisfactory due to the presence of Legionella in concentrations that are considered to be a health hazard (> or = 10(3)) in certain cases. Given the extent of the health risk in these surroundings, the difficulty in its assessment, and also considering the wide diffusion of general dental care, our investigation has confirmed the need to regularly monitor the microbiological condition of water in dental units.
Field and Numerical Study on Natural River Mixing
2011-06-01
transport of larvae from spawning to rearing habitats , or to mitigate potentially harmful human and environmental effects from wastewater discharges or...fluorescent dye was released for approximately one-hour through an 8mm diameter tube located 0.05 m below the waterline through a butterfly valve that was...multidimensional flow model for the white sturgeon critical- habitat reach, Kootenai River near Bonners Ferry, Idaho. U.S. Geological Survey Scientific
Temperature dependence of broadline NMR spectra of water-soaked, epoxy-graphite composites
NASA Astrophysics Data System (ADS)
Lawing, David; Fornes, R. E.; Gilbert, R. D.; Memory, J. D.
1981-10-01
Water-soaked, epoxy resin-graphite fiber composites show a waterline in their broadline proton NMR spectrum which indicates a state of intermediate mobility between the solid and free water liquid states. The line is still present at -42 °C, but shows a reversible decrease in amplitude with decreasing temperature. The line is isotropic upon rotation of the fiber axis with respect to the external magnetic field.
Leoni, E; Sanna, T; Zanetti, F; Dallolio, L
2015-12-01
The study aimed to assess the efficacy of an integrated water safety plan (WSP) in controlling Legionella re-growth in a respiratory hydrotherapy system located in a spa centre, supplied with sulphurous water, which was initially colonized by Legionella pneumophila. Heterotrophic plate counts, Pseudomonas aeruginosa, Legionella spp. were detected in water samples taken 6-monthly from the hydrotherapy equipment (main circuit, entry to benches, final outlets). On the basis of the results obtained by the continuous monitoring and the changes in conditions, the original WSP, including physical treatments of water and waterlines, environmental surveillance and microbiological monitoring, was integrated introducing a UV/ultrafiltration system. The integrated treatment applied to the sulphurous water (microfiltration/UV irradiation/ultrafiltration), waterlines (superheated stream) and distal outlets (descaling/disinfection of nebulizers and nasal irrigators), ensured the removal of Legionella spp. and P. aeruginosa and a satisfactory microbiological quality over time. The environmental surveillance was successful in evaluating the hazard and identifying the most suitable preventive strategies to avoid Legionella re-growth. Ultrafiltration is a technology to take into account in the control of microbial contamination of therapeutic spas, since it does not modify the chemical composition of the water, thus allowing it to retain its therapeutic properties.
33 CFR 334.761 - Naval Support Activity Panama City; St. Andrews Bay; restricted areas.
Code of Federal Regulations, 2010 CFR
2010-07-01
... waterline to 30°09′57.5″ N, 085°44′37″ W; then northerly to point of origin. (2) Area BA-1. The area is...) Area BA-2. The area is bounded by a line directly connecting the following coordinates (listed by... northerly to point of origin. (4) Area BA-3. The area is bounded by a line directly connecting the following...
33 CFR 334.761 - Naval Support Activity Panama City; St. Andrews Bay; restricted areas.
Code of Federal Regulations, 2011 CFR
2011-07-01
... waterline to 30°09′57.5″ N, 085°44′37″ W; then northerly to point of origin. (2) Area BA-1. The area is...) Area BA-2. The area is bounded by a line directly connecting the following coordinates (listed by... northerly to point of origin. (4) Area BA-3. The area is bounded by a line directly connecting the following...
Engineering For Ship Production: A Textbook
1986-06-01
content. (g) Bulbous Bow. Bulbous bows are wave-resistance-reducing devices. They incorporate displacement at the bow forefoot , which sets up a surface...displacement from the fore body in way of the load waterline entrance to the bow forefoot in the form of a faired-in bulb. More recently, the...install open-ended sounding tubes with striking plates welded to the tank bottom. Where the sounding tuba slopes at the end, it is common to close the
The Deterministic Mine Burial Prediction System
2009-01-12
or below the water-line, initial linear and angular velocities, and fall angle relative to the mine’s axis of symmetry. Other input data needed...c. Run_DMBP.m: start-up MATLAB script for the program 2. C:\\DMBP\\DMBP_src: This directory contains source code, geotechnical databases, and...approved for public release). b. \\Impact_35: The IMPACT35 model c. \\MakeTPARfiles: scripts for creating wave height and wave period input data from
Calibration of the TOPEX altimeter using a GPS buoy
NASA Technical Reports Server (NTRS)
Born, G. H.; Parke, Michael E.; Axelrad, P.; Gold, K. L.; Johnson, James; Key, K.; Kubitschek, Daniel G.; Christensen, Edward J.
1994-01-01
The use of a spar buoy equipped with a Global Positioning System (GPS) antenna to calibrate the height measurement of the TOPEX radar altimeter is described. In order to determine the height of the GPS antenna phase center above the ocean surface, the buoy was also equipped with instrumentation to measure the instantaneous location of the waterline, and tilt of the bouy from vertical. The experiment was conducted off the California coast near the Texaco offshore oil platform, Harvest, during cycle 34 of the TOPEX/POSEIDON observational period. GPS solutions were computed for the bouy position using two different software packages, K&RS and GIPSY-OASIS II. These solutions were combined with estimates of the waterline location on the bouy to yield the height of the ocean surface. The ocean surface height in an absolute coordinate system combined with knowledge of the spacecraft height from tracking data provides a computed altimeter range measurement. By comparing this computed value to the actual altimeter measurement, the altimeter bias can be calibrated. The altimeter height bias obtained with the buoy using K&RS was -14.6 +/- 4 cm, while with GIPSY-OASIS II it was -13.1 +/- 4 cm. These are 0.1 cm and 1.6 cm different from the -14.7 +/- 4 cm result obtained for this flight overflight with the tide gauge instruments located on Platform Harvest.
2013-08-01
corrosion can be found on tubes , tubesheets, and in steam- drums, most often near the waterline in steam boilers . Oxygen pitting can also occur anywhere...components present in the feedwater onto wetted boiler surfaces including fire- tubes and water- tubes . Since scale is a good insulator, the thicker...steel surfaces of a steam boiler . However, heavier scale accumulates on the lower steel surfaces of the tubes , mud-drum, and boiler shell. SLUDGE
A fast automatic target detection method for detecting ships in infrared scenes
NASA Astrophysics Data System (ADS)
Özertem, Kemal Arda
2016-05-01
Automatic target detection in infrared scenes is a vital task for many application areas like defense, security and border surveillance. For anti-ship missiles, having a fast and robust ship detection algorithm is crucial for overall system performance. In this paper, a straight-forward yet effective ship detection method for infrared scenes is introduced. First, morphological grayscale reconstruction is applied to the input image, followed by an automatic thresholding onto the suppressed image. For the segmentation step, connected component analysis is employed to obtain target candidate regions. At this point, it can be realized that the detection is defenseless to outliers like small objects with relatively high intensity values or the clouds. To deal with this drawback, a post-processing stage is introduced. For the post-processing stage, two different methods are used. First, noisy detection results are rejected with respect to target size. Second, the waterline is detected by using Hough transform and the detection results that are located above the waterline with a small margin are rejected. After post-processing stage, there are still undesired holes remaining, which cause to detect one object as multi objects or not to detect an object as a whole. To improve the detection performance, another automatic thresholding is implemented only to target candidate regions. Finally, two detection results are fused and post-processing stage is repeated to obtain final detection result. The performance of overall methodology is tested with real world infrared test data.
ISOLATION AND DETECTION OF GIARDIA CYSTS FROM WATER USING DIRECT IMMUNOFLUORESCENCE.
Sorenson, Stephen K.; Riggs, John L.; Dileanis, Peter D.; Suk, Thomas J.
1986-01-01
A water-sampling apparatus used for the isolation and detection of Giardia cysts in water has been designed and tested. The sampling apparatus uses one of a variety of pumps or waterline pressure to move water through a filter. Two of the optional pumps are lightweight enough to make the apparatus portable and thus suitable for sampling in remote areas. This technique of sample processing produces good cyst recovery in much less time than is required with previously established methods. Giardia cysts are identified using direct immunofluorescence.
1989-08-01
points on both the photos and base map. Transects placed at 100-m intervals along the waterline, oriented perpendicular to the gradient or slope just...the identifica- tion of major factors influencing bank erosion, independent variables measured included gradient of the land at the intersection of...have a very steep gradient , approaching vertical in some cases, broken only by intermittent minor drainages which have dissected terrace margins. b
Technical Suitability and Static Stability of Sungkur Fishing Boats for Fish and Shrimp Catching
NASA Astrophysics Data System (ADS)
Rusmilyansari; Rosadi, E.; Iriansyah
2017-10-01
Sungkur fishing gear is operated actively on one the side of fishing boat, which requires technical suitability and fishing gear stability to ensure success in fish catching. This is a case study which aimed to analyze some technical issues related to the boat, boat’s hydrostatic parameters, and the boat’s stability. The data were collected though observation, measuring the boat to obtain the offset table. The data were analyzed numerically and descriptively. The data were processed with technical formula, Microsoft Office’s Excel software, graphic display, minitab, statistical data processing, and maxsurf program. The research results showed that: (1) the sungkur fishing boat dimensional ratio L/B (6.47 - 7.00); L/D (10.90 - 11.20) and B/D (1.60 - 1.668) is within the range value of Indonesian fishing boats suitable to operate the fishing gear by towing or dragging. However, during fish catching operation, there have been problems in a hydrodynamic force due to the fishing gear movement, which affect the fish catching efficiency. (2) The boat’s coefficient of fineness is in the fine type shape; the displacement on each waterline has increased; the loads of the boat are getting larger following the increase of waterline from one to five; this is also shown from the increasing midship area value. Ton per centimeter immersion to change wl 1 by 1 cm needs 0.04 tons of weight. (3) Sungkur fishing boat have a good static stability, which is proven by the positive value of angle of maximum GZ by 79.1 - 83.6. In other words, the boat has the ability to return to its original position after tilting; however, stability dynamics happens because fishing gear operation are located on just one side of boat.
Aquatic burst locomotion by hydroplaning and paddling in common eiders (Somateria mollissima).
Gough, William T; Farina, Stacy C; Fish, Frank E
2015-06-01
Common eiders (Somateria mollissima) are heavy sea-ducks that spend a large portion of their time swimming at the water surface. Surface swimming generates a bow and hull wave that can constructively interfere and produce wave drag. The speed at which the wavelengths of these waves equal the waterline length of the swimming animal is the hull speed. To increase surface swimming speed beyond the hull speed, an animal must overtake the bow wave. This study found two distinct behaviors that eider ducks used to exceed the hull speed: (1) 'steaming', which involved rapid oaring with the wings to propel the duck along the surface of the water, and (2) 'paddle-assisted flying', during which the ducks lifted their bodies out of the water and used their feet to paddle against the surface while flapping their wings in the air. An average hull speed (0.732±0.046 m s(-1)) was calculated for S. mollissima by measuring maximum waterline length from museum specimens. On average, steaming ducks swam 5.5 times faster and paddle-assisted flying ducks moved 6.8 times faster than the hull speed. During steaming, ducks exceeded the hull speed by increasing their body angle and generating dynamic lift to overcome wave drag and hydroplane along the water surface. During paddle-assisted flying, ducks kept their bodies out of the water, thereby avoiding the limitations of wave drag altogether. Both behaviors provided alternatives to flight for these ducks by allowing them to exceed the hull speed while staying at or near the water surface. © 2015. Published by The Company of Biologists Ltd.
Maharjan, P; Dey, S; Huff, G; Zhang, W; Phillips, G K; Watkins, S
2017-08-01
Poultry waterlines are constructed using polyvinylchloride (PVC) material on which bacterial biofilm can easily form. Biofilm can harbor pathogens including avian pathogenic E. coli (APEC) strains. An in vitro evaluation was performed to determine if E. coli sero group O2 (avian pathogenic) could attach on a PVC surface that had pre-formed biofilm and if this phenomenon could be affected when water was treated with chlorine. Initially, biofilm growth was induced in PVC test coupons (15.16 cm2) for a 7-day period mimicking the waterline scenario in the first wk of poultry brooding; and then this biofilm was challenged with E. coli O2 seeded water in presence/absence of chlorine treatment. After rinsing, test coupons were sampled for bacterial (APC) and E. coli O2 enumeration at various occasions post seeding the pathogen and chlorine treatment. Day 7 APC recovered from coupons was 4.35 log10 cfu/cm2 in trial 1 and 3.66 log10 cfu/cm2 in trial 2. E. coli O2 was not recovered from chlorine treated test coupons (P < 0.05), whereas it was retrieved from untreated coupons (untreated contained > 3 log10 cfu/cm2 in trial 1 and > 2 log10 cfu/cm2 in trial 2). This study suggests that E. coli O2 can incorporate into pre-formed biofilm on a PVC surface within 24 h if water sanitation is not present, and the attachment time of the pathogen can prolong in the absence of already formed biofilm. © 2017 Poultry Science Association Inc.
The study method of estimation tidal flat with remote sensing waterlines
NASA Astrophysics Data System (ADS)
Gao, Zhiqiang; Liu, Xiangyang; Zhang, Yuanyuan; Liu, Chaoshun; Sun, Zhibin
2016-09-01
A tidal flat, the important potential land resource, is the sensitive area of intersection between the sea and the land. With Chinese HJ-1A/B remote sensing images of 2014 as data sources, based on the definition of a tidal flat, using DSAS software and Jenks Natural Breaks classification method synthetically, a more reasonable and accurate method of extracting tidal flat was imposed. In addition, the Bohai Rim was taken as an example to carry out investigation on the current situation of tidal flat. This paper can provide basic date and scientific evidence for rational utilization and sustainable development of tidal flat.
NASA Astrophysics Data System (ADS)
Eelsalu, Maris; Soomere, Tarmo; Männikus, Rain
2016-04-01
The management of beaches that suffer from sediment deficit and construction of nearshore infrastructure in locations with intense sediment transit require adequate predictions of the future of the relevant sedimentary systems. To a large extent, this task can be accomplished by using jointly the information about sediment texture and long-term changes in the dry beach volume and the location of the waterline. It is straightforward to evaluate relative changes in the dry beach volume from a succession of airborne laser scanning (ALS) surveys. We use in addition terrestrial laser scanning (TLS) technique to reduce ALS surveys performed with different devices and from different height to the same absolute height. This is accomplished using a TLS survey of a large horizontal surface of constant elevation within ALS snapshots. The most complicated, time-consuming and expensive task in beach management and planning of nearshore infrastructure is to get an adequate picture of the intensity and direction of underwater sediment transport processes. We demonstrate how a simple application of so-called inverse Bruun Rule makes it possible to evaluate the underwater volumetric changes for almost equilibrium beaches. The approach requires three data sets: wave statistics, sediment texture and changes in the average position of the waterline. The main properties of the wave climate, closure depths, magnitude and direction of wave-driven alongshore transport near the test areas are established using a triple nested high-resolution version of the wave model WAM that is forced for 34 years by high-quality marine winds. The relocation of the waterline is extracted from the ALS scanning of elevation isolines of 0.4-0.7 m on the subaerial beach. The technique has been applied to two basically different sections of Tallinn Bay, the Baltic Sea. Pirita Beach is gradually losing sand and requires beach refill while a moderate reclamation action is planned in the vicinity of gradually widening beach in the bayhead of this bay (Russalka beach). Sand volume in the latter area exhibits extensive interannual variations. The changes in the subaerial and underwater part are synchronised whereas the magnitude of changes in the underwater part is by a factor of 2-2.5 larger than similar changes in the subaerial part (that gains about 2000 m3/yr sand in 2008-2014). The discussed technique combined with classic estimates of the wave-driven sediment transport direction demonstrates that the Russalka beach is a convergence area of littoral flow. The existing pattern of sediment motions is such that even a minor shift in the coastline may lead to considerable increase in the transport of sand to neighbouring coastal sections. This conjecture is consistent with the general perception in coastal science that even seemingly small activities may have unexpectedly large potential for remote impacts. Such impacts are well known on high-energy open sea coasts but often considered as minor in relatively sheltered locations.
Gagné-Thivierge, Cynthia; Barbeau, Jean; Levesque, Roger C; Charette, Steve J
2018-06-25
Pseudomonas aeruginosa is an opportunistic pathogen associated with nosocomial infections and disease complications. In the lungs of cystic fibrosis (CF) individuals, biofilm growth plays a crucial role in the persistence and antibiotic resistance of P. aeruginosa. Some strains, adapted to the CF lung microenvironment, show distinguishable phenotypes linked to biofilm production when compared to other strains. Using a novel image analysis quantification approach with crystal violet-stained biofilms, we compared the biofilm formation of four different P. aeruginosa isolates in 24-well plates: PAO1, the reference strain, LESB58 from CF patients' lungs, and PPF-1 and Urg-7, two environmental isolates from dental unit waterlines. We also observed the formation of biofilm-like structures (BLSs) floating in the medium and investigated growth inhibition of the attached biofilm and BLS with Mg2+ or Zn2+. Urg-7 produced the most attached biofilms, but not the most BLSs. Attached biofilms had different responses to cations than BLSs did, but the effect of the cations was similar for all strains. These results demonstrate some diversity of biofilm formation in P. aeruginosa and indicate that chemical inhibition of attached biofilm formation for a specific strain or isolate cannot be predicative of a result on other P. aeruginosa strains or on BLSs.
Oosthuysen, Jeanné; Potgieter, Elsa; Fossey, Annabel
2014-12-01
Many publications are available on the topic of compliance with infection prevention and control in oral health-care facilities all over the world. The approaches of developing and developed countries show wide variation, but the principles of infection prevention and control are the same globally. This study is a systematic review and global perspective of the available literature on infection prevention and control in oral health-care facilities. Nine focus areas on compliance with infection-control measures were investigated: knowledge of infectious occupational hazards; personal hygiene and care of hands; correct application of personal protective equipment; use of environmental barriers and disposable items; sterilisation (recirculation) of instruments and handpieces; disinfection (surfaces) and housekeeping; management of waste disposal; quality control of dental unit waterlines, biofilms and water; and some special considerations. Various international studies from developed countries have reported highly scientific evidence-based information. In developed countries, the resources for infection prevention and control are freely available, which is not the case in developing countries. The studies in developing countries also indicate serious shortcomings with regard to infection prevention and control knowledge and education in oral health-care facilities. This review highlights the fact that availability of resources will always be a challenge, but more so in developing countries. This presents unique challenges and the opportunity for innovative thinking to promote infection prevention and control. © 2014 FDI World Dental Federation.
Water conservation study. Badger Army Ammunition Plant, Baraboo, Wisconsin. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-05-01
The purpose of this water conservation study is to identify projects which result in energy maintenance and cost savings in the process water distribution system at Badger Army Ammunition Plant (BAAP) in Baraboo, Wisconsin. A leak detection survey was performed on all process water piping with a diameter of 6 inches or greater. The leak detection analysis was performed using a combination of listening devices and preamplified-transducer systems to identify the majority of leak locations. When the location of the leak could not be readily identified using these methods, a leak correlator was used. The leak correlator determines leak locationmore » based on the time it takes for sound to travel from the leak to a waterline connection point.« less
2010-01-15
CAPE CANAVERAL, Fla. - Jim Lyon, biological science technician with the Merritt Island National Wildlife Refuge, carries a green sea turtle toward the waterline of the Banana River at NASA's Kennedy Space Center in Florida. A recent cold snap left this turtle and nearly 2,000 others "stunned" and in need of help. Many of the turtles were rescued from the Mosquito Lagoon, with others coming from the Indian River Lagoon and Cocoa Beach. Biologists, environmentalists, wildlife experts and other volunteers joined forces with a massive rescue effort at the Merritt Island National Wildlife Refuge, where the turtles were identified, examined and transported to rehabilitation facilities throughout Florida and South Georgia. The animals stayed at these facilities until local waters warmed up to safe temperatures. Photo credit: NASA/Troy Cryder
Atlas, Ronald M; Stoeckel, Donald M; Faith, Seth A; Minard-Smith, Angela; Thorn, Jonathan R; Benotti, Mark J
2015-07-21
To study hydrocarbon biodegradation in marsh sediments impacted by Macondo oil from the Deepwater Horizon well blowout, we collected sediment cores 18-36 months after the accident at the marshes in Bay Jimmy (Upper Barataria Bay), Louisiana, United States. The highest concentrations of oil were found in the top 2 cm of sediment nearest the waterline at the shorelines known to have been heavily oiled. Although petroleum hydrocarbons were detectable, Macondo oil could not be identified below 8 cm in 19 of the 20 surveyed sites. At the one site where oil was detected below 8 cm, concentrations were low. Residual Macondo oil was already highly weathered at the start of the study, and the concentrations of individual saturated hydrocarbons and polycyclic aromatic hydrocarbons continued to decrease over the course of the study due to biodegradation. Desulfococcus oleovorans, Marinobacter hydrocarbonoclasticus, Mycobacterium vanbaalenii, and related mycobacteria were the most abundant oil-degrading microorganisms detected in the top 2 cm at the oiled sites. Relative populations of these taxa declined as oil concentrations declined. The diversity of the microbial community was low at heavily oiled sites compared to that of the unoiled reference sites. As oil concentrations decreased over time, microbial diversity increased and approached the diversity levels of the reference sites. These trends show that the oil continues to be biodegraded, and microbial diversity continues to increase, indicating ongoing overall ecological recovery.
Effect of iodine on mercury concentrations in dental-unit wastewater.
Stone, Mark E; Kuehne, John C; Cohen, Mark E; Talbott, Jonathan L; Scott, John W
2006-02-01
This study was undertaken to determine whether iodine used to control bacteria in dental unit waterlines could increase mercury concentrations in dental wastewater. The study was conducted in four parts. Part 1. Solutions containing iodine in concentrations ranging from zero (control) to 20 mg/L were mixed with ground and sieved dental amalgam and then allowed to equilibrate by settling. Cold vapor atomic absorption spectrometry was used to determine mercury levels in the settled supernatants at 24 h and at 7 days. Part 2. Deionized water was pumped through an iodine-releasing water-treatment cartridge, collected, and mixed with ground and sieved dental amalgam. Mercury levels in settled supernatants were measured at 24 h and at 7 days. Part 3. Iodine in water from two commercial iodine-releasing cartridges was measured using Inductively Couple Plasma Mass Spectrometry. Part 4. Baseline mercury levels in settled supernatants from wastewater collected from two dental chairs were compared to samples taken from chairs equipped with iodine-releasing cartridges. Part 1. A linear correlation between iodine and mercury concentration (r2=0.9167 and 0.9459, respectively, both P<0.001) was seen at both 24 h and 7 days. Part 2. Mean mercury levels in 24h samples were 3.0 times higher than the controls (0.2864 mg/L compared with 0.0939mg/L for the 24 h controls). Mean mercury levels in the 7-day samples were 5.9 times higher than the 7-day controls (0.2048 mg/L compared with 0.0348 mg/L for the 7-day controls). Part 3. The effluent from two iodine-releasing cartridges showed iodine concentrations averaging 3.2 mg/L (n=10, SD=0.8, range=2.5-4.6). Part 4. Data from the clinical study showed a statistically significant 2.5-fold increase in mercury levels with iodine-containing samples compared to baseline (0.0853 mg/L, n=18, SD=0.0441 and 0.0345 mg/L, n=18, SD=0.0145, respectively; P<0.001). Data suggest that iodine can increase concentrations of dissolved mercury in dental unit wastewater.
Porteous, Nuala; Schoolfield, John; Luo, Jie; Sun, Yuyu
2011-01-01
A study was conducted to test the biofilm-controlling functions of N-halamine tubing over an eight-month period. A laboratory system, simulating a teaching dental clinic, was used to test rechargeable N-halamine tubing (T) compared to an untreated control (C) using the unit manufacturer's tubing. For the long-term study, a recharged tubing (RC) treated with bleach was used to compare with the test (T) and the control (C) tubing. Source tap water was cycled through the lines at 1.4 mL/minute, five minutes on and 25 minutes off, eight hours/day, five days/week. Every three weeks, samples of effluent, recovered adherent bacteria from inside tubing surfaces, and SEM images were examined for bacterial and biofilm growth. After sampling, a recharging solution of chlorine bleach (1 : 10 dilution) was run through T and RC lines, left overnight, and rinsed out the next morning. One-way ANOVAs and Spearman correlations were performed to detect significant differences for T, RC, and C, and determine significance with time period and source water, respectively. Mean log CFU/mL for C effluent > T (p = 0.028), and C tubing > T (p = 0.035). Spearman correlations were significant between effluent and source water level for T (rho = 0.817), and T tubing (0.750); between RC tubing and source water level (rho = 0.836), and time (rho = 0.745); and between C and time (rho = 0.873). SEM imaging confirmed the presence of biofilm inside RC and C, but not inside T. N-halamine tubing completely inhibited biofilm formation without negatively affecting the physical properties of the effluent water. Further research on N-halamine tubing using a pure water source is recommended, as T effluent bacterial levels reflected the source tap water quality and proliferation of planktonic bacteria with no biofilm activity.
Porteous, Nuala; Schoolfield, John; Luo, Jie; Sun, Yuyu
2015-01-01
Objective A study was conducted to test the biofilm-controlling functions of N-halamine tubing over an eight-month period. Methods A laboratory system, simulating a teaching dental clinic, was used to test rechargeable N-halamine tubing (T) compared to an untreated control (C) using the unit manufacturer’s tubing. For the long-term study, a recharged tubing (RC) treated with bleach was used to compare with the test (T) and the control (C) tubing. Source tap water was cycled through the lines at 1.4 mL/minute, five minutes on and 25 minutes off, eight hours/day, five days/week. Every three weeks, samples of effluent, recovered adherent bacteria from inside tubing surfaces, and SEM images were examined for bacterial and biofilm growth. After sampling, a recharging solution of chlorine bleach (1:10 dilution) was run through T and RC lines, left overnight, and rinsed out the next morning. One-way ANOVAs and Spearman correlations were performed to detect significant differences for T, RC, and C, and determine significance with time period and source water, respectively. Results Mean log CFU/mL for C effluent > T (p = 0.028), and C tubing > T (p = 0.035). Spearman correlations were significant between effluent and source water level for T (rho = 0.817), and T tubing (0.750); between RC tubing and source water level (rho = 0.836), and time (rho = 0.745); and between C and time (rho = 0.873). SEM imaging confirmed the presence of biofilm inside RC and C, but not inside T. Conclusion N-halamine tubing completely inhibited biofilm formation without negatively affecting the physical properties of the effluent water. Further research on N-halamine tubing using a pure water source is recommended, as T effluent bacterial levels reflected the source tap water quality and proliferation of planktonic bacteria with no biofilm activity. PMID:22403982
Remote sensing of intertidal morphological change in Morecambe Bay, U.K., between 1991 and 2007
NASA Astrophysics Data System (ADS)
Mason, D. C.; Scott, T. R.; Dance, S. L.
2010-04-01
Tidal Flats are important examples of extensive areas of natural environment that remain relatively unaffected by man. Monitoring of tidal flats is required for a variety of purposes. Remote sensing has become an established technique for the measurement of topography over tidal flats. A further requirement is to measure topographic changes in order to measure sediment budgets. To date there have been few attempts to make quantitative estimates of morphological change over tidal flat areas. This paper illustrates the use of remote sensing to measure quantitative and qualitative changes in the tidal flats of Morecambe Bay during the relatively long period 1991-2007. An understanding of the patterns of sediment transport within the Bay is of considerable interest for coastal management and defence purposes. Tidal asymmetry is considered to be the dominant cause of morphological change in the Bay, with the higher currents associated with the flood tide being the main agency moulding the channel system. Quantitative changes were measured by comparing a Digital Elevation Model (DEM) of the intertidal zone formed using the waterline technique applied to satellite Synthetic Aperture Radar (SAR) images from 1991-1994, to a second DEM constructed from airborne laser altimetry data acquired in 2005. Qualitative changes were studied using additional SAR images acquired since 2003. A significant movement of sediment from below Mean Sea Level (MSL) to above MSL was detected by comparing the two Digital Elevation Models, though the proportion of this change that could be ascribed to seasonal effects was not clear. Between 1991 and 2004 there was a migration of the Ulverston channel of the river Leven north-east by about 5 km, followed by the development of a straighter channel to the west, leaving the previous channel decoupled from the river. This is thought to be due to independent tidal and fluvial forcing mechanisms acting on the channel. The results demonstrate the effectiveness of remote sensing for measurement of long-term morphological change in tidal flat areas. An alternative use of waterlines as partial bathymetry for assimilation into a morphodynamic model of the coastal zone is also discussed.
TLSpy: An Open-Source Addition to Terrestrial Lidar Workflows
NASA Astrophysics Data System (ADS)
Frechette, J. D.; Weissmann, G. S.; Wawrzyniec, T. F.
2008-12-01
Terrestrial lidar scanners (TLS) that capture three dimensional (3D) geometry with cm scale precision present many new opportunities in the Earth Sciences and related fields. However, the lack of domain specific tools impedes full and efficient utilization of the information contained in these datasets. Most processing and analysis is performed using a variety of manufacturing, surveying, airborne lidar, and GIS software. Although much overlap exists, inevitably some needs are not addressed by these applications. TLSpy provides a plugin driven framework with 3D visualization capabilities that encourages researchers to fill these gaps. The goal is to free researchers from the intellectual overhead imposed by user and data interface design, enabling rapid development of TLS specific processing and analysis algorithms. We present two plugins as examples of problems that TLSpy is being applied to. The first plugin corrects for the strong influence of target orientation on TLS measured reflectance intensities. It calculates the distribution of incidence angles and intensities in an input scan and assists the user in fitting a reflectance model to the distribution. The model is then used to normalize input intensities, minimizing the impact of surface orientation and simplifying the extraction of quantitative data from reflectance measurements. Although reasonable default models can be determined the large number of factors influencing reflectance values require that the plugin be designed for maximum flexibility, allowing the user to adjust all model parameters and define new reflectance models as needed. The second plugin helps eliminate multipath reflections from water surfaces. Characterized by a lower intensity mirror image of the subaerial bank appearing below the water surface, these reflections are a common problem in scans containing water. These erroneous reflections can be removed by manually selecting points that lie on the waterline, fitting a plane to the points, and deleting points below that plane. This plugin simplifies the process by automatically identifying waterline points using characteristic changes in geometry and intensity. Automatic identification is often faster and more reliable than manual identification, however, manual control is retained as a fallback for degenerate cases.
Earth Observations taken by the Expedition 20 crew
2009-07-01
ISS020-E-016279 (1 July 2009) --- Millennium Island is featured in this image photographed by an Expedition 20 crew member on the International Space Station. Millennium Island ? known as Caroline Island prior to 2000 ? is located at the southern end of the Line Islands in the South Pacific Ocean. This uninhabited island is part of the Republic of Kiribati, an island nation comprised of 32 atolls (including Millennium Island) and one raised coral island. Millennium Island is formed from a number of smaller islets built on coral reefs. The coral reefs grew around a now-submerged volcanic peak, leaving a ring of coral around an inner lagoon. The islands above the waterline are composed primarily of limestone rock and sand derived from the reefs. At a maximum height of approximately 6 m above sea level, Millennium Island has been identified as being at great risk from sea level rise by the United Nations. The islets of Millennium Island are readily visible in this photograph as irregular green vegetated areas surrounding the inner lagoon. The shallow lagoon waters are a lighter blue than the deeper surrounding ocean water; tan linear ?fingers? within the lagoon are the tops of corals. The two largest islets are Nake Islet and South Islet, located at the north and south ends of Millennium Island respectively. The ecosystem of Millennium Island is considered to be relatively pristine despite periods of human habitation, guano mining, and agricultural activities, and the island has been recommended as both a World Heritage site and Biosphere Reserve.
Construction of shipping channels in the Detroit River—History and environmental consequences
Bennion, David H.; Manny, Bruce A.
2011-01-01
The Detroit River is one of the most biologically diverse areas in the Great Lakes basin. It has been an important international shipping route since the 1820s and is one of the busiest navigation centers in the United States. Historically, it supported one of the most profitable Lake Whitefish (Coregonus clupeaformis) commercial fisheries in the Great Lakes. Since 1874, the lower Detroit River has been systematically and extensively modified, by construction of deepwater channels, to facilitate commercial shipping. Large-scale dredging, disposal of dredge spoils, and construction of water-level compensating works has greatly altered channel morphology and flow dynamics of the river, disrupting ecological function and fishery productivity of the river and influencing Great Lakes water levels. From 1874 to 1968, major construction projects created 96.5 kilometers (60 miles) of shipping channels, removed over 46,200,000 m3 of material, covered 4,050 hectares (40.5 square kilometers) of river bottom with dredge spoils, and built 85 hectares of above-waterline compensating works at a total cost of US$283 million. Interest by industries and government agencies to develop the river further for shipping is high and increasing. Historically, as environmental protection agencies were created, construction impacts on natural resources were increasingly addressed during the planning process and, in some cases, assessments of these impacts greatly altered or halted proposed construction projects. Careful planning of future shipping-channel construction and maintenance projects, including a thorough analysis of the expected environmental impacts, could greatly reduce financial costs and ecological damages as compared to past shipping-channel construction projects.
Corrosion of radioactive waste tanks containing washed sludge and precipitates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bickford, D.F.; Congdon, J.W.; Oblath, S.B.
1988-05-01
At the US Department of Energy (DOE) Savannah River Plant, the corrosion of carbon steel storage tanks containing alkaline, high-level radioactive waste is controlled by specification of limits on waste composition and temperature. Laboratory tests, conducted to determine minimum corrosion inhibitor levels, indicated pitting of carbon steel near the waterline for proposed storage conditions. In situ electrochemical measurements of full-scale radioactive process demonstrations were conducted to assess the validity of laboratory tests. The in situ results are compared to those of laboratory tests, with particular regard given to simulated solution composition. Transition metal hydroxide sludge contains strong passivating species formore » carbon steel. Washed precipitate contains organic species that lower solution pH and tend to reduce passivating films, requiring higher inhibitor concentrations than the 0.01 M nitrite required for reactor fuel reprocessing wastes.« less
Cross-shore transport of nearshore sediment by river plume frontal pumping
NASA Astrophysics Data System (ADS)
Horner-Devine, Alexander R.; Pietrzak, Julie D.; Souza, Alejandro J.; McKeon, Margaret A.; Meirelles, Saulo; Henriquez, Martijn; Flores, Raúl P.; Rijnsburger, Sabine
2017-06-01
We present a new mechanism for cross-shore transport of fine sediment from the nearshore to the inner shelf resulting from the onshore propagation of river plume fronts. Onshore frontal propagation is observed in moorings and radar images, which show that fronts penetrate onshore through the nearshore and surf zone, almost to the waterline. During frontal passage a two-layer counterrotating velocity field characteristic of tidal straining is immediately set up, generating a net offshore flow beneath the plume. The seaward flow at depth carries with it high suspended sediment concentrations, which appear to have been generated by wave resuspension in the nearshore region. These observations describe a mechanism by which vertical density stratification can drive exchange of material between the nearshore region and the inner shelf. To our knowledge these are the first observations of this frontal pumping mechanism, which is expected to play an important role in sediment transport near river mouths.
NASA Astrophysics Data System (ADS)
In the early part of the 19th century it was commonly thought that marine life existed only in the upper levels of the oceans. In later years, animals were recovered from successively greater depths, so that by the time of the Challenger expedition in 1873, life seemed to exist almost everywhere in the ocean and on the sea floor. The remarkable abundance of the deep sea fascinated naturalists world-wide, and in 1877 the U.S. Coast Survey steamer Blake was outfitted for deep dredging and trawling, to be done in conjunction with sounding surveys of the eastern U.S. continental shelf and slope. With a waterline length of only 140 feet (43 m), the Blake was a rather small vessel for such arduous service, but these limitations were more than compensated for by Alexander Agassiz, who directed the first dredging survey, and Lieutenant Sigsbee, who commanded the vessel.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bickford, D.F.; Congdon, J.W.; Oblath, S.B.
1987-01-01
At the U.S. Department of Energy's Savannah River Plant, corrosion of carbon steel storage tanks containing alkaline, high-level radioactive waste is controlled by specification of limits on waste composition and temperature. Processes for the preparation of waste for final disposal will result in waste with low corrosion inhibitor concentrations and, in some cases, high aromatic organic concentrations, neither of which are characteristic of previous operations. Laboratory tests, conducted to determine minimum corrosion inhibitor levels indicated pitting of carbon steel near the waterline for proposed storage conditions. In situ electrochemical measurements of full-scale radioactive process demonstrations have been conducted to assessmore » the validity of laboratory tests. Probes included pH, Eh (potential relative to a standard hydrogen electrode), tank potential, and alloy coupons. In situ results are compared to those of the laboratory tests, with particular regard given to simulated solution composition.« less
Messinger, Max; Silman, Miles
2016-11-01
Unmanned aerial vehicles (UAVs) offer new opportunities to monitor pollution and provide valuable information to support remediation. Their low-cost, ease of use, and rapid deployment capability make them ideal for environmental emergency response. Here we present a UAV-based study of the third largest coal ash spill in the United States. Coal ash from coal combustion is a toxic industrial waste material present worldwide. Typically stored in settling ponds in close proximity to waterways, coal ash poses significant risk to the environment and drinking water supplies from both chronic contamination of surface and ground water and catastrophic pond failure. We sought to provide an independent estimate of the volume of coal ash and contaminated water lost during the rupture of the primary coal ash pond at the Dan River Steam Station in Eden, NC, USA and to demonstrate the feasibility of using UAVs to rapidly respond to and measure the volume of spills from ponds or containers that are open to the air. Using structure-from-motion (SfM) imagery analysis techniques, we reconstructed the 3D structure of the pond bottom after the spill, used historical imagery to estimate the pre-spill waterline, and calculated the volume of material lost. We estimated a loss of 66,245 ± 5678 m 3 of ash and contaminated water. The technique used here allows rapid response to environmental emergencies and quantification of their impacts at low cost, and these capabilities will make UAVs a central tool in environmental planning, monitoring, and disaster response. Copyright © 2016 Elsevier Ltd. All rights reserved.
Cross-infection risks associated with current procedures for using high-speed dental handpieces.
Lewis, D L; Boe, R K
1992-01-01
When a dye solution used to simulate patient material was either injected into high-speed dental handpiece (drill) waterlines or applied to the equipment externally, internal air turbine chambers became contaminated. These chambers served as a reservoir of the material, which was slowly dislodged by air expelled during subsequent handpiece operation and which was diluted by water spray used for cooling the drilling surface. Considering the fact that patient materials could reside in internal parts of the equipment that are not usually disinfected and that the material may be subsequently sprayed into cuts and abrasions in the oral cavity, the common approach to reprocessing handpieces (external wiping in combination with flushing) may pose unacceptably high risks to those individuals treated soon after infected patients. Therefore, unless reliable data on cross-infection frequencies are obtained and prove it unnecessary, heat-treating high-speed handpieces between each patient should be considered an essential component of standard procedures whenever universal precautions are practiced in dentistry. PMID:1537909
Specification for a surface-search radar-detection-range model
NASA Astrophysics Data System (ADS)
Hattan, Claude P.
1990-09-01
A model that predicts surface-search radar detection range versus a variety of combatants has been developed at the Naval Ocean Systems Center. This model uses a simplified ship radar cross section (RCS) model and the U.S. Navy Oceanographic and Atmospheric Mission Library Standard Electromagnetic Propagation Model. It provides the user with a method of assessing the effects of the environment of the performance of a surface-search radar system. The software implementation of the model is written in ANSI FORTRAN 77, with MIL-STD-1753 extensions. The program provides the user with a table of expected detection ranges when the model is supplied with the proper environmental radar system inputs. The target model includes the variation in RCS as a function of aspect angle and the distribution of reflected radar energy as a function of height above the waterline. The modeled propagation effects include refraction caused by a multisegmented refractivity profile, sea-surface roughness caused by local winds, evaporation ducting, and surface-based ducts caused by atmospheric layering.
Aerodynamic Efficiency Analysis on Modified Drag Generator of Tanker-Ship Using Symmetrical Airfoil
NASA Astrophysics Data System (ADS)
Moranova, Starida; Rahmat Hadiyatul A., S. T.; Indra Permana S., S. T.
2018-04-01
Time reduction of tanker ship spent in the sea should be applied for solving problems occured in oil and gas distribution, such as the unpunctuality of the distribution and oil spilling. The aerodynamic design for some parts that considered as drag generators is presumed to be one of the solution, utilizing our demand of the increasing speed. This paper suggests two examples of the more-aerodynamic design of a part in the tanker that is considered a drag generator, and reports the value of drag generated from the basic and the suggested aerodynamic designs. The new designs are made by adding the NACA airfoil to the cross section of the drag generator. The scenario is assumed with a 39 km/hour speed of tanker, neglecting the hydrodynamic effects occured in the tanker by cutting it at the waterline which separated the drag between air and water. The results of produced drag in each design are calculated by Computational Fluid Dynamic method.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosenqvist, Martin; Bertron, Alexandra; Fridh, Katja
This article presents a study on concrete alteration mechanisms due to 55 years of exposure to river water. Many hydro power structures in cold regions suffer from concrete deterioration at the waterline. Progressive disintegration of the concrete surface leads to exposure of the coarse aggregate and eventually the reinforcing steel. Concrete cylinders drilled out at four vertically different locations on the upstream face of a concrete dam were analysed by electron microprobe analysis, X-ray diffraction, thermogravimetry and scanning electron microscopy. Long-term exposure to the river water, which is regarded as soft water, has led to chemical and mineralogical zonation ofmore » the cement paste. Up to five zones with different chemical and mineralogical composition, parallel to the upstream face, were observed in the outermost 8–9 mm of the concrete. Decalcification, precipitation of secondary ettringite and the formation of a magnesium-rich silica gel constitute the major changes that define the zones.« less
NASA Technical Reports Server (NTRS)
Chanton, Jeffrey P.; Martens, Christopher S.; Kelley, Cheryl A.; Crill, Patrick M.; Showers, William J.
1992-01-01
The stable carbon isotopic composition of methane associated with and emitted by the two dominant emergent macrophytes abundant in the many Alaskan tundra lakes, Carex rostrata and Arctophila fulva, is determined. The carbon isotopic composition of the methane was -58.6 +/- 0.5 (n=2) for Arctophila and -66.6 +/- 2.5 (n=6) for Carex. The methane emitted by these species is depleted in C-13 by 12 per mil for Arctophila and 18 per mil for Carex relative to methane withdrawn from plant stems 1-2 cm below the waterline. The results suggest more rapid transport of (C-12)H4 relative to (C-13)H4 through plants to the atmosphere. Plant stem methane concentrations ranged from 0.2 to 4.0 percent in Arctophila, with an isotopic composition of -46.1 +/- 4.3 percent (n=8). Carex stem methane concentrations ranged from 150 to 1200 ppm, with an isotopic composition of -48.3 +/- 1.4 per mil (n=3).
Contested Waterlines: The Wave-Line Theory and Shipbuilding in the Nineteenth Century.
Ferreiro, Larrie D; Pollara, Alexander
2016-04-01
Ship hydrodynamics in the nineteenth century was dominated by John Scott Russell's wave-line theory. Russell, a prominent British shipbuilder and scientist, argued that wavemaking was the primary source of resistance for ships, and that by designing ships according to trigonometric curves and proportions (the wave line) this resistance could effectively be eliminated. From the 1840s to the 1880s, shipbuilders such as John Willis Griffiths, Donald McKay and George Steers designed their clipper ships (like Sea Witch and Flying Cloud) and yachts (America) with wave-line hulls, while authors like Jules Verne referenced Russell's theory. The wave line slowly faded after William Froude developed his laws of ship resistance. The article examines how Russell's theory became accepted by technical experts and the wider public to become the most widely known ship hydrodynamic theory of the 1800s-a reminder of how a persuasive idea can take hold of an entire profession, and even the public, for a long time.
Seeing from Space: What Icebergs Can Tell Us About Ice-ocean Interactions
NASA Astrophysics Data System (ADS)
Scheick, J.; Enderlin, E. M.; Hamilton, G. S.
2017-12-01
Icebergs are an important component of the ice-ocean system, yet until recently they have remained the focus of relatively few studies. Icebergs are an important distributed freshwater and nutrient source and can pose significant hazards for navigation and infrastructure, warranting further study. Importantly, icebergs are also easily observable en masse using satellite imagery and other remote sensing platforms, allowing for the collection of large datasets from already existing archives. Here we present some of the many ways that remotely sensed icebergs can be used to inform our understanding of ice-ocean interactions, as well as some of the limitations of these methods and what information is still needed. We will explore the size and spatial distribution of icebergs through time and what that can tell us about the calving behavior of the parent glacier and/or ocean-driven melting below the waterline. We will also explore the use of icebergs as depth finders and drifters to infer bathymetry and components of fjord circulation, respectively.
Fleming, R.W.; Johnson, R.B.; Schuster, R.L.; Williams, G.P.
1988-01-01
PART A: The Manti landslide is in Manti Canyon on the west side of the Wasatch Plateau in central Utah. In early June 1974, coincident with the melting of a snowpack, a rock slump/debris flow occurred on the south rim of Manti Canyon. Part of the slumped material mixed with meltwater and mobilized into a series of debris flows that traveled down the slope a distance of as much as 1.2 km. Most of the flows were deposited either at the base of the steep rocks of the canyon rim or at the site of an old, silted reservoir. A small part of the debris flow deposit stopped on the head of the very large, relatively inactive Manti landslide. The upper part of the landslide began moving as cracks propagated downslope. A little more than a year later, August 1975, movement extended the full length of the old landslide, and about 19 million m 3 of debris about 3 km long and as much as 800 m wide threatened to block the canyon. The upper part of the landslide apparently had moved small amounts between 1939 and 1974. This part of the landslide, identifiable on pre-1974 aerial photographs, consisted of well-defined linears on the landslide flanks and two large internal toe bulges about 2 km downslope from the head. The abrupt reactivation in 1974 proceeded quickly after the debris flows had provided a surcharge in the head and crown area. Movement propagated downslope at 4-5 m/h for the first few days following reactivation. During 1974, the reactivation probably encompassed all the parts of the landslide that had moved small amounts between 1939 and 1974. Movement nearly or completely stopped during the winter of 1974-75, but began again in the spring of 1975. The landslide enlarged from the flanks of the internal toe bulges to Manti Creek at a rate of 2-3 m/h. Movement stopped again during the winter of 1975-76 and began again in the spring of 1976. Thereafter, the displacements have been small compared to earlier. The displacement rates for the landslide were variable depending on where and when they were measured. At the waterline crossing, about 500 m downslope from the head, the maximum rate was about 1 mid, and the peak rate occurred within the first 30 days following reactivation. Almost a year later, during the spring of 1975, the rates there were 0.1-0.3 mid. By the time movement had propagated 2.5 km downslope to Manti Creek, more than 40 m of displacement had occurred at the waterline. Cracks were first noted at Manti Creek on June 21,1975, but movement was initially very slow there. The maximum rate of sliding of about 3.1 mid occurred during the period September 1-19,1975, and the movement decreased and stopped during the winter of 1975-76. At the time the lower part of the landslide was moving rapidly, the rate farther upslope was small. The result was that the landslide changed from being in compression, which was caused by loading from above, to being in extension, which was caused by the lower part moving faster than the upper part. One of the results of the extension was that the landslide pulled apart on a steeper segment of the slope and exposed the failure surface. Since the fall of 1975, the landslide has been separated into two independent parts. There has been no movement in the lower part, whereas movements in the upper part have continued at a rate of a few meters per year. Although the landslide is 6.5 km from the nearest permanent dwelling, it cost nearly $2 million in actual damages and in preparation for a major disaster that did not occur. The waterline for the city of Manti was replaced and a well was drilled to provide an emergency water supply. PART B: The Manti landslide abuts, at its toe, another large landslide called the North slide. In 1975, public officials were concerned that continued movement of the Manti landslide would trigger reactivation of the North slide. In response to this threat, four borings were placed in the North slide to obtain samples for testing and information
Testing the effect of water in crevasses on a physically based calving model
Cook, S.; Zwinger, T.; Rutt, I.C.; O’Neel, S.; Murray, T.
2012-01-01
A new implementation of a calving model, using the finite-element code Elmer, is presented and used to investigate the effects of surface water within crevasses on calving rate. For this work, we use a two-dimensional flowline model of Columbia Glacier, Alaska. Using the glacier's 1993 geometry as a starting point, we apply a crevasse-depth calving criterion, which predicts calving at the location where surface crevasses cross the waterline. Crevasse depth is calculated using the Nye formulation. We find that calving rate in such a regime is highly dependent on the depth of water in surface crevasses, with a change of just a few meters in water depth causing the glacier to change from advancing at a rate of 3.5 km a-1 to retreating at a rate of 1.9 km a-1. These results highlight the potential for atmospheric warming and surface meltwater to trigger glacier retreat, but also the difficulty of modeling calving rates, as crevasse water depth is difficult to determine either by measurement in situ or surface mass-balance modelling.
Water tunnel flow visualization study of a 4.4 percent scale X-31 forebody
NASA Technical Reports Server (NTRS)
Cobleigh, Brent R.; Delfrate, John
1994-01-01
A water-tunnel test of a 4.4 percent-scale, forebody-only model of the X-31 aircraft with different forebody strakes and nosebooms has been performed in the Flow Visualization Facility at the NASA Dryden Flight Research Center. The focus of the study was to determine the relative effects of the different configurations on the stability and symmetry of the high-angle-of-attack forebody vortex flow field. The clean, noseboom-off configuration resisted the development of asymmetries in the primary vortices through 70 deg angle of attack. The wake of the X-31 flight test noseboom configuration significantly degraded the steadiness of the primary vortex cores and promoted asymmetries. An alternate L-shaped noseboom mounted underneath the forebody had results similar to those seen with the configuration, enabling stable, symmetrical vortices up to 70 deg angle of attack. The addition of strakes near the radome tip along the waterline increased the primary vortex strength while it simultaneously caused the vortex breakdown location co move forward. Forebody strakes did not appear to significantly reduce the asymmetries in the forebody vortex field in the presence of the flight test noseboom.
An Alternative Approach of Coastal Sea-Level Observation from Remote Sensing Imageries
NASA Astrophysics Data System (ADS)
Peng, H. Y.; Tseng, K. H.; Chung-Yen, K.; Lin, T. H.; Liao, W. H.; Chen, C. F.
2017-12-01
Coastal sea level can be observed as waterline changes along a coastal digital elevation model (DEM). However, most global DEMs, such as the Shuttle Radar Topography Mission (SRTM) DEM with 30 m resolution, provide limited coverage over coastal area due to the impermeability of radar signal over water and the lack of low-tide coincidence. Therefore, we aim to extend to coverage of SRTM DEM for the determination of intertidal zone and to monitor sea-level changes along the entire coastline of Taiwan (>1200km). We firstly collect historical cloud-free images since the 1980s, including Landsat series, SPOT series and Sentinel-2, and then calculate the Modified Normalized Difference Water Index (MNDWI) to identify water pixels. After computing water appearance probability of each pixel, it is converted into actual elevation by introducing the DTU10 tide model for high tide and low tide boundaries. A coastal DEM of intertidal zone is reconstructed and the accuracy is at 50 cm level as compared with in situ DEM built by an unmanned aerial vehicle (UAV). Finally, we use this product to define the up-to-date intertidal zone and estimate sea-level changes by using remote sensing snapshots.
NASA Astrophysics Data System (ADS)
Enos, David George
Assessment of the effect of cathodic protection on a chloride contaminated bridge pile involves the definition of the hydrogen embrittlement behavior of the pearlitic reinforcement combined with quantification of the local (i.e., at the steel/concrete interface) chemical and electrochemical conditions, both prior to and throughout the application of cathodic protection. The hydrogen embrittlement behavior of the reinforcement was assessed through a combination of Devanathan/Stachurski permeation experiments to quantify subsurface hydrogen concentrations, CsbH, as a function of the applied hydrogen overpotential, eta, and crack initiation tests for bluntly notched and fatigue pre-cracked tensile specimens employing elastic-plastic finite element analysis and linear elastic fracture mechanics, respectively. A threshold mobile lattice hydrogen concentration for embrittlement of 2×10sp{-7} mol/cmsp3 was established for bluntly notched and fatigue pre-cracked specimens. Crack initiation occurred by the formation of shear cracks oriented at an angle approaching 45sp° from the tensile axis, as proposed by Miller and Smith (Miller, 1970), in regions where both the longitudinal and shear stresses were maximized (i.e., near the notch root). These Miller cracks then triggered longitudinal splitting which continued until fast fracture of the remaining ligament occurred. Instrumented laboratory scale piles were constructed and partially immersed in ASTM artificial ocean water. With time, localized corrosion (crevicing) was initiated along the reinforcement, and was accompanied by an acidic shift in the pH of the occluded environment due to ferrous ion hydrolysis. Cathodic protection current densities from -0.1 muA/cmsp2 to -3.0 muA/cmsp2 were applied via a skirt anode located at the waterline. Current densities as low as 0.66 muA/cmsp2 were sufficient to deplete the dissolved oxygen concentration at the steel/concrete interface and result in the observance of hydrogen production within regions near the waterline where the pH had decreased locally due to ferrous ion hydrolysis. By combining the effect of local cathodic protection level as a function of position along the reinforcement on hydrogen absorption with the information on the hydrogen embrittlement characteristics of the reinforcement as a function of hydrogen concentration, safe windows for the application of cathodic protection may be identified. Although hydrogen production and absorption were detected at -0.66 muA/cmsp2, concentrations which were of sufficient magnitude to be considered embrittling were not realized until -1.33 muA/cmsp2. Local hydrogen concentrations were compared to the 100 mV, 200 mV, and -780 mVsbSCE absolute potential cathodic protection criteria. With the exception of the 100 mV depolarization/decay criteria, it was not possible to sufficiently protect the high corrosion rate splash zone of the piling without exceeding the threshold hydrogen concentration for embrittlement at some zone within the reinforcement.
The breakup of large tabular icebergs - direct observations and theoretical considerations
NASA Astrophysics Data System (ADS)
Wadhams, P.
2013-12-01
Peter Wadhams and Till Wagner Dept. of Applied Mathematics and Theoretical Physics (DAMTP), University of Cambridge. We review the factors governing the stability, dynamics and decay of icebergs and describe areas where current models are inadequate. These include questions such as draft changes in capsizing icebergs; iceberg trajectory modelling; the melt rate of the ice underside and ways of reducing it; and wave-induced flexure and its role in the break-up of tabular icebergs. In July 2012 the authors worked on a very large (42 sq km) tabular iceberg in Baffin Bay, which had calved from the Petermann Glacier in NW Greenland. We measured incoming swell spectrum and the iceberg response; also the role of buoyancy forces due to erosion of a waterline wave cut and the creation of an underwater ram. The iceberg broke up while we were on it, allowing an instrumental measurement of the calving event. The experiments were included in the BBC-2 film 'Operation Iceberg' shown on Nov 1 2012 and repeated on Nov 18. We conclude that two processes interacted in the break-up event: increased bending stress due to buoyancy of underwater rams; and direct flexural strain due to incidence of ocean swell. Implications for icebergs in the open sea are estimated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bickford, D.F.; Congdon, J.W.; Oblath, S.B.
1986-12-01
At the US Department of Energy's Savannah River Plant, corrosion of carbon steel storage tanks containing alkaline, high-level radioactive waste is controlled by specification of limits on waste composition and temperature. Processes for the preparation of waste for final disposal will result in waste with low corrosion inhibitor concentrations and, in some cases, high aromatic organic concentrations, neither of which are characteristic of previous operations. Laboratory tests, conducted to determine minimum corrosion inhibitor levels indicated pitting of carbon steel near the waterline for proposed storage conditions. In situ electrochemical measurements of full-scale radioactive process demonstrations have been conducted to assessmore » the validity of laboratory tests. Probes included pH, Eh (potential relative to a standard hydrogen electrode), tank potential, and alloy coupons. In situ results are compared to those of the laboratory tests, with particular regard given to simulated solution composition. Transition metal hydroxide sludge contains strong passivating species for carbon steel. Washed precipitate contains organic species that lower solution pH and tend to reduce passivating films, requiring higher inhibitor concentrations than the 0.01 molar nitrite required for reactor fuel reprocessing wastes. Periodic agitation, to keep the organic phase suspended, or cathodic protection are possible alternatives to higher nitrite inhibitor concentrations.« less
Maturation, fecundity, and intertidal spawning of Pacific sand lance in the northern Gulf of Alaska
Robards, Martin D.; Piatt, John F.; Rose, G.A.
1999-01-01
Pacific sand lance Ammodytes hexapterus in Kachemak Bay, Alaska, showed no sexual dimorphism in length-to-weight (gonad-free) ratio or length-at-age relationship. Most matured in their second year, males earlier in the season than females, but females (31%) attained a higher gonadosomatic index than males (21%). Sand lance spawned intertidally once each year in late September and October on fine gravel or sandy beaches soon after the seasonal peak in water temperatures. Sand lance in Cook Inlet and Prince William Sound displayed similar maturation schedules. Schools were dominated 2: 1 by males as they approached the intertidal zone at a site where spawning has taken place for decades. Sand lance spawned vigorously in dense formations, leaving scoured pits in beach sediments. Fecundity of females (93–199 mm) was proportional to length, ranging from 1468 to 16 081 ova per female. About half of the overall spawning school fecundity was derived from age group 1 females (55% of the school by number). Spawned eggs were 1·02 mm in diameter, demersal, slightly adhesive, and deposited in the intertidal just below the waterline. Sand lance embryos developed over 67 days through periods of intertidal exposure and sub-freezing air temperatures.
The coastline remote sensing survey for Zhao Shu Island in Xisha Islands based on WorldView-2
NASA Astrophysics Data System (ADS)
Li, Li; Zhong, Chang; Kong, Fanping
2014-11-01
Due to diastrophism, tide action and human activities, the coastline is always in flux. There are lots of coral islands in the south sea of China. Remote sensing survey for the coastline not only can reassert the necessity and importance of coral protection, but also can provide basic data and scientific basis for island ecologic protection, reasonable utilization of land resources. The study area named Zhao Shu Island lies in Jintong Islands of Xisha. It is a coral island which has people inhabited. Using WorldView-2 satellite remote sensing images as data sources we carry out three phases of coastline investigation and monitoring. The satellite data phases are 2002, 2010 and 2013. Firstly, affirm the bands valuable for color composition on the basis of spectral and correlation analysis. Then extract the coastline by a series of image process, such as image correction, fusion, waterline extraction and coastline revision. Finally determine the coastline types and length by artificial interpretation. The results show that the island length is gradually smaller, which means the island area is reducing. The beach bedrock coast in northern island was eroded seriously especially during the period between 2010 and 2013. In addition, the shoal head shape in the western island changed a lot.
Mondav, Rhiannon; McCalley, Carmody K; Hodgkins, Suzanne B; Frolking, Steve; Saleska, Scott R; Rich, Virginia I; Chanton, Jeff P; Crill, Patrick M
2017-08-01
Biogenic production and release of methane (CH 4 ) from thawing permafrost has the potential to be a strong source of radiative forcing. We investigated changes in the active layer microbial community of three sites representative of distinct permafrost thaw stages at a palsa mire in northern Sweden. The palsa site (intact permafrost and low radiative forcing signature) had a phylogenetically clustered community dominated by Acidobacteria and Proteobacteria. The bog (thawing permafrost and low radiative forcing signature) had lower alpha diversity and midrange phylogenetic clustering, characteristic of ecosystem disturbance affecting habitat filtering. Hydrogenotrophic methanogens and Acidobacteria dominated the bog shifting from palsa-like to fen-like at the waterline. The fen (no underlying permafrost, high radiative forcing signature) had the highest alpha, beta and phylogenetic diversity, was dominated by Proteobacteria and Euryarchaeota and was significantly enriched in methanogens. The Mire microbial network was modular with module cores consisting of clusters of Acidobacteria, Euryarchaeota or Xanthomonodales. Loss of underlying permafrost with associated hydrological shifts correlated to changes in microbial composition, alpha, beta and phylogenetic diversity associated with a higher radiative forcing signature. These results support the complex role of microbial interactions in mediating carbon budget changes and climate feedback in response to climate forcing. © 2017 Society for Applied Microbiology and John Wiley & Sons Ltd.
Determining Tidal Phase Differences from X-Band Radar Images
NASA Astrophysics Data System (ADS)
Newman, Kieran; Bell, Paul; Brown, Jennifer; Plater, Andrew
2017-04-01
Introduction Previous work by Bell et. al. (2016) has developed a method using X-band marine radar to measure intertidal bathymetry, using the waterline as a level over a spring-neap tidal cycle. This has been used in the Dee Estuary to give a good representation of the bathymetry in the area. However, there are some sources of inaccuracy in the method, as a uniform spatial tidal signal is assumed over the entire domain. Motivation The method used by Bell et. al. (2016) applies a spatially uniform tidal signal to the entire domain. This fails to account for fine-scale variations in water level and tidal phase. While methods are being developed to account for small-scale water level variations using high resolution modelling, a method to determine tidal phase variations directly from the radar intensity images could be advantageous operationally. Methods The tidal phase has been computed using two different methods, with hourly averaged images from 2008. In the first method, the cross-correlation between each raw pixel time series and a tidal signal at a number of lags is calculated, and the lag with the highest correlation to the pixel series is recorded. For the second method, the same method of correlation is used on signals generated by tracking movement of buoys, which show up strongly in the radar image as they move on their moorings with the tidal currents. There is a broad agreement between the two methods, but validation is needed to determine the relative accuracy. The phase has also been calculated using a Fourier decomposition, and agrees broadly with the above methods. Work also needs to be done to separate areas where the recorded phase is due to tidal current (mostly subtidal areas) or due to elevation (mostly the wetting/drying signal in intertidal areas), by classifying radar intensities by the phases and amplitudes of the tides. Filtering out signal variations due to wind strength and attenuation of the radar signal will also be applied. Validation Validation will be attempted using data from a POLCOMS-WAM model run for Liverpool Bay at 180m resolution for February 2008 (Brown, 2011), and ongoing work to develop a model at 5m resolution using DELFT3D-FLOW. There are also a series of ADCP and other direct measurements of tidal current and elevation available, although periods of measurement do not all overlap. However, this could still be used for some validation. Conclusion While this work is in very early stages, it could present a method to determine fine-scale variations in tidal phase without a network of current recorders, and an improvement in the accuracy of bathymetric methods using X-band Radar. References Bell, P.S., Bird, C.O., Plater, A.J., 2016. A temporal waterline approach to mapping intertidal areas using X-band marine radar. Coastal Engineering, 07: 84-101. Brown, J.M., Bolaños, R., Wolf, J., 2011. Impact assessment of advanced coupling features in a tide-surge-wave model, POLCOMS-WAM, in a shallow water application. Journal of Marine Systems, 87: 13-24. Deltares, 2010. Delft3D FLOW. Delft: Deltares.
McGregor, Edward E.; Van Horn, Richard; Arnow, Ted
1974-01-01
This map provides information on the location and distribution of three general types of geologic materials in part of Salt Lake County, including the southeastern part of Salt Lake City, Utah. These materials have different physical properties that are pertinent to comprehensive planning and zoning, land-use studies, and engineering usage. The map should be of use in preliminary studies to determine the depth to different general types of foundation material and to determine the potential for settlement of the ground surface during major earthquakes, which could result in damage to waterlines, gaslines, large buildings, and other major engineering structures.The lines on the map are generalized. Lines showing the thickness of loosely packed sediments are based on drillers’ logs of 27 water wells in and near the 35-square-mile part of the quadrangle west of the mountains – less than one data point for each square mile. Lines showing the depth to bedrock are based on indirect geophysical data, and the data points are more widely scattered. The map may be useful as a general guide in planning, but investigations by qualified specialists should be made for detailed evaluations of specific areas.references to other reports of possible interest to the reader are included at the end of this text.
NASA Astrophysics Data System (ADS)
House, Mitchell Wayne
Concrete is the most widely used material for construction of wastewater collection, storage, and treatment infrastructure. The chemical and physical characteristics of hydrated portland cement make it susceptible to degradation under highly acidic conditions. As a result, some concrete wastewater infrastructure may be susceptible to a multi-stage degradation process known as microbially induced corrosion, or MIC. MIC begins with the production of aqueous hydrogen sulfide (H2S(aq)) by anaerobic sulfate reducing bacteria present below the waterline. H2S(aq) partitions to the gas phase where it is oxidized to sulfuric acid by the aerobic sulfur oxidizing bacteria Thiobacillus that resides on concrete surfaces above the waterline. Sulfuric acid then attacks the cement paste portion of the concrete matrix through decalcification of calcium hydroxide and calcium silica hydrate coupled with the formation of expansive corrosion products. The attack proceeds inward resulting in reduced service life and potential failure of the concrete structure. There are several challenges associated with assessing a concrete's susceptibility to MIC. First, no standard laboratory tests exist to assess concrete resistance to MIC. Straightforward reproduction of MIC in the laboratory is complicated by the use of microorganisms and hydrogen sulfide gas. Physico-chemical tests simulating MIC by immersing concrete specimens in sulfuric acid offer a convenient alternative, but do not accurately capture the damage mechanisms associated with biological corrosion. Comparison of results between research studies is difficult due to discrepancies that can arise in experimental methods even if current ASTM standards are followed. This thesis presents two experimental methods to evaluate concrete resistance to MIC: one biological and one physico-chemical. Efforts are made to address the critical aspects of each testing method currently absent in the literature. The first method presented is a new test to evaluate performance of concrete specimens under conditions designed to accelerate MIC. Concrete specimens representing 12 mixture designs were inoculated with 5 species of Thiobacillus bacteria and placed in a biological growth chamber designed to encourage bacterial growth and sulfuric acid production by optimizing temperature, delivering necessary nutrients, and providing hydrogen sulfide gas. Results indicate that using supplementary cementitious materials, limestone aggregates, and sulfate resistant cement can improve resistance to MIC. It is interesting to note that this study showed that unlike many other durability problems the role of water to cement ratio was unclear. The second method presented is a sulfuric acid immersion study designed to evaluate the resistance of 12 concrete mixture designs to 5 concentrations of sulfuric acid. Experimental protocols (like those in ASTM) previously considered trivial were found to have a dramatic effect on experimental results. It was found that using supplementary cementitious materials, limestone coarse aggregate, and sulfate resistant cement can increase concrete resistance to moderate sulfuric acid concentrations. The primary damage mechanism was observed to change depending on sulfuric acid concentration. Rapid deterioration of specimens exposed to aggressive sulfuric acid solutions indicates that degradation of concrete under the most severe MIC conditions (i.e., a pH < 1.0) cannot be prevented by strictly manipulating concrete mixture proportions. A holistic approach is needed for these situations that considers environmental conditions as well.
Bottom Topographic Changes of Poyang Lake During Past Decade Using Multi-temporal Satellite Images
NASA Astrophysics Data System (ADS)
Zhang, S.
2015-12-01
Poyang Lake, as a well-known international wetland in the Ramsar Convention List, is the largest freshwater lake in China. It plays crucial ecological role in flood storage and biological diversity. Poyang Lake is facing increasingly serious water crises, including seasonal dry-up, decreased wetland area, and water resource shortage, all of which are closely related to progressive bottom topographic changes over recent years. Time-series of bottom topography would contribute to our understanding of the lake's evolution during the past several decades. However, commonly used methods for mapping bottom topography fail to frequently update quality bathymetric data for Poyang Lake restricted by weather and accessibility. These deficiencies have limited our ability to characterize the bottom topographic changes and understanding lake erosion or deposition trend. To fill the gap, we construct a decadal bottom topography of Poyang Lake with a total of 146 time series medium resolution satellite images based on the Waterline Method. It was found that Poyang Lake has eroded with a rate of -14.4 cm/ yr from 2000 to 2010. The erosion trend was attributed to the impacts of human activities, especially the operation of the Three Gorge Dams, sand excavation, and the implementation of water conservancy project. A decadal quantitative understanding bottom topography of Poyang Lake might provide a foundation to model the lake evolutionary processes and assist both researchers and local policymakers in ecological management, wetland protection and lake navigation safety.
2008-05-02
ISS016-E-019394 (30 Dec. 2007) --- Al Wadj Bank, Saudi Arabia is featured in this image photographed by an Expedition 16 crewmember on the International Space Station. Saudi Arabia boasts the most coral reefs of any Middle Eastern country, as it includes coastline along both the Red Sea and Gulf of Arabia. This high resolution image depicts a portion of the Al Wadj Bank, located along the northern Red Sea coast. Despite the relatively high salinity of Red Sea water (compared to other oceans), approximately 260 species of coral are found here, according to scientists. Large tracts of the Saudi Arabian coastline are undeveloped, and reefs in these areas are in generally good ecological health. However, reefs located near large urban centers like Jeddeh have suffered degradation due to land reclamation, pollution, and increased terrigeneous sediment input. The Al Wadj Bank includes a healthy and diverse reef system, extensive seagrass beds, and perhaps the largest population of dugong -- a marine mammal similar to the North American manatee -- in the eastern Red Sea. The portion of the Bank in this image illustrates the complex form and topography of the reef system. Several emergent islands (tan) - surrounded primarily by dark green seagrass - are visible, the largest located at top left. Only the islands are above the waterline -- over the reef structures the water color ranges from light teal (shallow) to turquoise (increasing depth). The southern edge of the reef is well indicated by the deep, dark blue water of the Red Sea at image top.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brandt, C.A.; Rickard, W.H. Jr.; Hefty, M.G.
This report describes the development of the reclamation project for the Hanford Site Near Surface Test Facility (NSTF), its implementation, and preliminary estimates of its success. The goal of the reclamation project is to return disturbed sites as nearly as practicable to their original conditions using native species. Gable Mountain is dominated by two plant communities: a big sagebrush (Artemisia tridentata) -- Sandberg's bluegrass (Poa sandbergii) community and a stiff sagebrush (Artemisia rigida) -- Sandberg's bluegrass community. Disassembly of the site installations began on March 15, 1988, and the site was returned to original contours by December 12, 1988. Twomore » separate revegetation methods were employed at the NSTF to meet differing site constraints. Vegetative cover and density in the revegetation plots were assessed in April 1989 and again in June 1989 and 1990. It is extremely unlikely that the sand pit, borrow pit, box cuts, generator pad area, or ventilation fan area will reach the reclamation objectives set for these areas within the next 50 years without further intervention. These areas currently support few living plants. Vegetation on revegetated native soils appears to be growing as expected. Vegetation growth on the main waterline is well below the objective. To date, no shrubs have grown on the area, growth of native grasses is well below the objective, and much of the area has been covered with the pit run material, which may not support adequate growth. Without further treatments, the areas without the pit run material will likely revert to a nearly pure cheatgrass condition. 44 refs., 13 figs., 7 tabs.« less
NASA Astrophysics Data System (ADS)
Ockelford, A.; Crabbe, E.; Crowe Curran, J.; Parsons, D. R.; Shugar, D. H.; Burr, A.; Kennedy, K.; Coe, T.
2017-12-01
Wood jams are an important and ubiquitous feature of many river channels with their number, placement and spatial configuration determining their influence on channel morphology and flow characteristics. Further, engineered log jams are increasingly being constructed to develop, restore or maintain habitat diversity for key indicator specie such as salmon. However, questions remain as to the inter relationships between the logjams, the channel morphology, the flow characteristics and the habitat diversity under low flow conditions. Four engineered and one natural logjam were analyzed over a 3km reach of the South Fork Nooksack River, North Cascades National Park, USA during the summer low flow period. Non-intrusive three-dimensional topographic surveys of the river bed morphology surrounding the logjams was collected using a shallow water multibeam system. This was combined with terrestrial laser scans of the structure of the log jams above the waterline. Co-located high resolution flow velocity data was collected using an Acoustic Doppler Current Profiler. Discussion concentrates on providing a quantitative understanding of the effect of logjams on reach scale morphodynamics under low flow conditions. Multivariate statistical analysis of flow and topographic data in combination with log jam morphology allow the influences of the logjam on habitat suitability for key indicator species to be quantified. Results will be framed in terms of the effectiveness of the different logjam configurations on generating and promoting habitat diversity such as to aid future design and implementation.
NASA Astrophysics Data System (ADS)
Lorenz, Ralph D.; Tokano, Tetsuya; Newman, Claire E.
2012-01-01
We use two independent General Circulation Models (GCMs) to estimate surface winds at Titan’s Ligeia Mare (78° N, 250° W), motivated by a proposed mission to land a floating capsule in this ∼500 km hydrocarbon sea. The models agree on the overall magnitude (∼0.5-1 m/s) and seasonal variation (strongest in summer) of windspeeds, but details of seasonal and diurnal variation of windspeed and direction differ somewhat, with the role of surface exchanges being more significant than that of gravitational tides in the atmosphere. We also investigate the tidal dynamics in the sea using a numerical ocean dynamics model: assuming a rigid lithosphere, the tidal amplitude is up to ∼0.8 m. Tidal currents are overall proportional to the reciprocal of depth-with an assumed central depth of 300 m, the characteristic tidal currents are ∼1 cm/s, with notable motions being a slosh between Ligeia’s eastern and western lobes, and a clockwise flow pattern. We find that a capsule will drift at approximately one tenth of the windspeed, unless measures are adopted to augment the drag areas above or below the waterline. Thus motion of a floating capsule is dominated by the wind, and is likely to be several km per Earth day, a rate that will be readily measured from Earth by radio navigation methods. In some instances, the wind vector rotates diurnally such that the drift trajectory is epicyclic.
Meiszberg, A M; Johnson, A K; Sadler, L J; Carroll, J A; Dailey, J W; Krebs, N
2009-12-01
Assimilating accurate behavioral events over a long period can be labor-intensive and relatively expensive. If an automatic device could accurately record the duration and frequency for a given behavioral event, it would be a valuable alternative to the traditional use of human observers for behavioral studies. Therefore, the objective of this study was to determine the accuracy in the time spent at the waterer and the number of visits to the waterer by individually housed nursery pigs between human observers scoring video files using Observer software (OBS) and an automatic water meter Hobo (WM, control) affixed onto the waterline. Eleven PIC USA genotype gilts (22 +/- 2 d of age; 6.5 +/- 1.4 kg of BW) were housed individually in pens with ad libitum access to a corn-based starter ration and one nipple waterer. Behavior was collected on d 0 (day of weaning), 7, and 14 of the trial using 1 color camera positioned over 4 attached pens and a RECO-204 DVR at 1 frame per second. For the OBS method, 2 experienced observers recorded drinking behavior from the video files, which was defined as when the gilt placed her mouth over the nipple waterer. Data were analyzed using nonparametric methods and the general linear model and regression procedures in SAS. The experimental unit was the individual pen housing 1 gilt. The GLM model included the method of observation (WM vs. OBS) and time (24 h) as variables, and the gilt nested within method was used as the error term. Gilts consumed more water (P = 0.04) on d 14 than on d 0. The time of day affected (P < 0.001) the number of visits and the time spent at the waterer regardless of the method. However, the OBS method underestimated (P < 0.001) the number of visits to the waterer (3.48 +/- 0.33 visits/h for OBS vs. 4.94 +/- 0.33 for WM) and overestimated (P < 0.001) the time spent at the waterer (22.6 +/- 1.46 s/h for OBS vs. 13.9 +/- 1.43 for WM) compared with WM. The relationship between the 2 methods for prediction of time spent at the waterer and number of visits made by the gilts was weak (R(2) = 0.56 and 0.69, respectively). Collectively, these data indicate that the use of the traditional OBS method for quantifying drinking behavior in pigs can be misleading. Quantifying drinking behavior and perhaps other behavioral events via the OBS method must be more accurately validated.
Dorr, Paul M; Nemechek, Megan S; Scheidt, Alan B; Baynes, Ronald E; Gebreyes, Wondwossen A; Almond, Glen W
2009-08-01
To evaluate variation of drinking-water flow rates in swine finishing barns and the relationship between drinker flow rate and plasma tetracycline concentrations in pigs housed in different pens. Cross-sectional (phase 1) and cohort (phase 2) studies. 13 swine finishing farms (100 barns with 7,122 drinkers) in phase 1 and 100 finishing-stage pigs on 2 finishing farms (1 barn/farm) in phase 2. In phase 1, farms were evaluated for water-flow variation, taking into account the following variables: position of drinkers within the barn, type of drinker (swing or mounted), pig medication status, existence of designated sick pen, and existence of leakage from the waterline. In phase 2, blood samples were collected from 50 pigs/barn (40 healthy and 10 sick pigs) in 2 farms at 0, 4, 8, 24, 48, and 72 hours after initiation of water-administered tetracycline HCl (estimated dosage, 22 mg/kg [10 mg/lb]). Plasma tetracycline concentrations were measured via ultraperformance liquid chromatography. Mean farm drinker flow rates ranged from 1.44 to 2.77 L/min. Significant differences in flow rates existed according to drinker type and whether tetracycline was included in the water. Mean drinker flow rates and plasma tetracycline concentrations were significantly different between the 2 farms but were not different between healthy and sick pigs. The plasma tetracycline concentrations were typically < 0.3 microg/mL. Many factors affected drinker flow rates and therefore the amount of medication pigs might have received. Medication of pigs with tetracycline through water as performed in this study had questionable therapeutic value.
Richards, Joseph M.; Huizinga, Richard J.
2018-06-19
Clearwater Lake, on the Black River near Piedmont in Reynolds County, Missouri, was constructed in 1948 and is operated by the U.S. Army Corps of Engineers for flood-risk reduction, recreation, and fish and wildlife habitat. The lake area is about 1,800 acres with about 34 miles of shoreline at the conservation pool elevation of 498 feet. Since the completion of the lake in 1948, sedimentation likely has caused the storage capacity of the lake to decrease gradually. The loss of storage capacity can decrease the effectiveness of the lake to mitigate flooding, and excessive sediment accumulation also can reduce aquatic habitat in some areas of the lake. Many lakes operated by the U.S. Army Corps of Engineers have periodic bathymetric and sediment surveys to monitor the status of the lake. The U.S. Geological Survey completed one such survey of Clearwater Lake in 2008 during a period of high lake level using bathymetric surveying equipment consisting of a multibeam echosounder, a singlebeam echosounder, 1/3 arc-second National Elevation Dataset data (used outside the multibeam echosounder survey extent), and the waterline derived from 2008 aerial light detection and ranging (lidar) data. In May 2017, the U.S. Geological Survey, in cooperation with the U.S. Army Corps of Engineers, surveyed the bathymetry of Clearwater Lake to prepare an updated bathymetric map and a surface area and capacity table. The 2008 survey was contrasted with the 2017 survey to document the changes in the bathymetric surface of the lake.
Maharjan, Pramir; Huff, Geraldine; Zhang, Wen; Watkins, Susan
2017-01-01
An in vitro experiment was conducted to understand the nature of biofilm growth on polyvinyl chloride (PVC) surface when exposed to suboptimal-quality microbial water (>4 log 10 cfu/mL) obtained from a poultry drinking water source mimicking water in waterlines during the first week of poultry brooding condition. PVC sections (internal surface area of 15.16 cm 2 ) were utilized in the study to grow biofilm. After a 7-d test period, test coupons with 7-day-old biofilm were transferred into autoclaved municipal water and then treated with either chlorine-based or hydrogen peroxide-based sanitizer at bird drinking water rate, to see the impact on removal of biofilm formed on test coupons. Two trials (T1 and T2) were conducted. Test coupons used in T1 and T2 had the bacterial growth of 3.67 (SEM 0.04) and 3.97 (SEM 0.11) log 10 cfu/cm 2 on d 7. After sanitizer application, chlorine-based sanitizer removed bacteria in biofilm completely (0 cfu/cm 2 ) within 24 h post treatment whereas hydrogen peroxide-based sanitizer reduced the counts to 1.68 log 10 cfu/cm 2 (P < 0.05) by 48 h post sanitizer application. Control remained the same (P > 0.05). Results indicated that biofilm formation can occur quickly under suboptimal water condition on PVC surface, and sanitizer application helped mitigate already formed biofilm, yet chlorine proved to be more effective than hydrogen peroxide. © 2016 Poultry Science Association Inc.
Winston, Gary; Lerman, Shlomo; Goldberger, Shalom; Collins, Malcolm; Leventhal, Alex
2003-06-01
Herein, we report on the actual events linked to an ammonia spillage into the main waterline of the Tel-Aviv metropolitan area and its surrounding municipalities. Based upon a large magnitude increase of unknown origin in the turbidity and ammonia levels of the main drinking water supply, area residents were warned of possible serious contamination and advised to refrain from drinking tap water until further notice. Turbidity was later linked only to CaCO3, which was precipitated from the water due to the rise in pH caused by the excessive ammonia levels. The source of the ammonia (a malfunction of the measurement buoy in the ammonia tank) was not identified until several days after the warning was issued. The toxicological implications of the turbidity and ammonia elevations are considered and reconciled with the management strategies that followed. Of consequence to the management of this crisis was the approach of Ministry of Health officials to regard the ammonia, from the onset, as an indicator of several possible sources of origin rather than as a contaminant. Decision-making policies were hampered by ineffective communication between the national water supplier and government health officials. An outcome of this crisis was a heightened awareness of the potential of a water crisis occurring during peace time and not only in association with terrorist activities, to which Israeli citizens are highly sensitized. Finally, the present paper may serve to guide municipal environmental and health officials more appropriately in the event of similar drinking water crises in Israel or elsewhere.
Kruse, Sarah A; Bernstein, Brock; Scholz, Astrid J
2015-10-01
The 27 oil and gas platforms offshore southern California will eventually reach the end of their useful lifetimes (estimated between 2015 and 2030) and will be decommissioned. Current state and federal laws and regulations allow for alternative uses in lieu of the complete removal required in existing leases. Any decommissioning pathway will create a complex mix of costs, benefits, opportunities, and constraints for multiple user groups. To assist the California Natural Resources Agency in understanding these issues, we evaluated the potential socioeconomic impacts of the 2 most likely options: complete removal and partial removal of the structure to 85 feet below the waterline with the remaining structure left in place as an artificial reef-generally defined as a manmade structure with some properties that mimic a natural reef. We estimated impacts on commercial fishing, commercial shipping, recreational fishing, nonconsumptive boating, and nonconsumptive SCUBA diving. Available data supported quantitative estimates for some impacts, semiquantitative estimates for others, and only qualitative approximations of the direction of impact for still others. Even qualitative estimates of the direction of impacts and of user groups' likely preferred options have been useful to the public and decision makers and provided valuable input to the project's integrative decision model. Uncertainty surrounds even qualitative estimates of the likely direction of impact where interactions between multiple impacts could occur or where user groups include subsets that would experience the same option differently. In addition, we were unable to quantify effects on ecosystem value and on the larger regional ecosystem, because of data gaps on the population sizes and dynamics of key species and the uncertainty surrounding the contribution of platforms to available hard substrate and related natural populations offshore southern California. © 2015 SETAC.
Evaluation of deep vadose zone contaminant flux into groundwater: Approach and case study
NASA Astrophysics Data System (ADS)
Oostrom, M.; Truex, M. J.; Last, G. V.; Strickland, C. E.; Tartakovsky, G. D.
2016-06-01
For sites with a contaminant source located in the vadose zone, the nature and extent of groundwater contaminant plumes are a function of the contaminant flux from the vadose zone to groundwater. Especially for thick vadose zones, transport may be relatively slow making it difficult to directly measure contaminant flux. An integrated assessment approach, supported by site characterization and monitoring data, is presented to explain current vadose zone contaminant distributions and to estimate future contaminant flux to groundwater in support of remediation decisions. The U.S. Department of Energy Hanford Site (WA, USA) SX Tank Farm was used as a case study because of a large existing contaminant inventory in its deep vadose zone, the presence of a limited-extent groundwater plume, and the relatively large amount of available data for the site. A predictive quantitative analysis was applied to refine a baseline conceptual model through the completion of a series of targeted simulations. The analysis revealed that site recharge is the most important flux-controlling process for future contaminant flux. Tank leak characteristics and subsurface heterogeneities appear to have a limited effect on long-term contaminant flux into groundwater. The occurrence of the current technetium-99 groundwater plume was explained by taking into account a considerable historical water-line leak adjacent to one of the tanks. The analysis further indicates that the vast majority of technetium-99 is expected to migrate into the groundwater during the next century. The approach provides a template for use in evaluating contaminant flux to groundwater using existing site data and has elements that are relevant to other disposal sites with a thick vadose zone.
Evaluation of deep vadose zone contaminant flux into groundwater: Approach and case study.
Oostrom, M; Truex, M J; Last, G V; Strickland, C E; Tartakovsky, G D
2016-06-01
For sites with a contaminant source located in the vadose zone, the nature and extent of groundwater contaminant plumes are a function of the contaminant flux from the vadose zone to groundwater. Especially for thick vadose zones, transport may be relatively slow making it difficult to directly measure contaminant flux. An integrated assessment approach, supported by site characterization and monitoring data, is presented to explain current vadose zone contaminant distributions and to estimate future contaminant flux to groundwater in support of remediation decisions. The U.S. Department of Energy Hanford Site (WA, USA) SX Tank Farm was used as a case study because of a large existing contaminant inventory in its deep vadose zone, the presence of a limited-extent groundwater plume, and the relatively large amount of available data for the site. A predictive quantitative analysis was applied to refine a baseline conceptual model through the completion of a series of targeted simulations. The analysis revealed that site recharge is the most important flux-controlling process for future contaminant flux. Tank leak characteristics and subsurface heterogeneities appear to have a limited effect on long-term contaminant flux into groundwater. The occurrence of the current technetium-99 groundwater plume was explained by taking into account a considerable historical water-line leak adjacent to one of the tanks. The analysis further indicates that the vast majority of technetium-99 is expected to migrate into the groundwater during the next century. The approach provides a template for use in evaluating contaminant flux to groundwater using existing site data and has elements that are relevant to other disposal sites with a thick vadose zone. Copyright © 2016 Elsevier B.V. All rights reserved.
Evaluation of Deep Vadose Zone Contaminant Flux into Groundwater: Approach and Case Study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oostrom, Martinus; Truex, Michael J.; Last, George V.
For sites with a contaminant source located in the vadose zone, the nature and extent of groundwater contaminant plumes are a function of the contaminant flux from the vadose zone to groundwater. Especially for thick vadose zones, transport may be relatively slow making it difficult to directly measure contaminant flux. An integrated assessment approach, supported by site characterization and monitoring data, is presented to explain current vadose zone contaminant distributions and to estimate future contaminant flux to groundwater in support of remediation decisions. The U.S. Department of Energy Hanford Site (WA, USA) SX Tank Farm was used as a casemore » study because of a large existing contaminant inventory in its deep vadose zone, the presence of a limited-extent groundwater plume, and the relatively large amount of available data for the site. A predictive quantitative analysis was applied to refine a baseline conceptual model through the completion of a series of targeted simulations. The analysis revealed that site recharge is the most important flux-controlling process for future contaminant flux. Tank leak characteristics and subsurface heterogeneities appear to have a limited effect on long-term contaminant flux into groundwater. The occurrence of the current technetium-99 groundwater plume was explained by taking into account a considerable historical water-line leak adjacent to one of the tanks. The analysis further indicates that the vast majority of technetium-99 is expected to migrate into the groundwater during the next century. The approach provides a template for use in evaluating contaminant flux to groundwater using existing site data and has elements that are relevant to other disposal sites with a thick vadose zone.« less
Tung, Min-Che; Hsu, Bing-Mu; Tao, Chi-Wei; Lin, Wei-Chen; Tsai, Hsiu-Feng; Ji, Dar-Der; Shen, Shu-Min; Chen, Jung-Sheng; Shih, Feng-Cheng; Huang, Yu-Li
2013-08-01
Naegleria fowleri can cause primary amoebic meningoencephalitis, a rapidly developing and highly lethal infectious disease. The first confirmed case of primary amoebic meningoencephalitis in Taiwan was reported in November 2011, in which the patient visited a thermal spring recreational area 1 week prior to hospitalisation. Water sampling was performed to verify the presence of Naegleria at the facility. According to our results, 32% and 20% of recreational water samples were contaminated with Naegleria spp. and Acanthamoeba spp., respectively. The genotypes of Naegleria identified at the hot spring included N. fowleri, Naegleria australiensis and Naegleria lovaniensis. Using PCR, it was determined that the strain of N. fowleri in one sample possessed the same genotype 2 as the clinical isolate. Thus, the thermal spring was suggested to be the likely source of infection. This is the first known instance of simultaneously isolating N. fowleri from both a patient as well as from a hot spring in Taiwan. Following this initial study, the pools at the thermal spring recreational area were drained, scrubbed and disinfected, and a follow-up study was performed 1 month later. Naegleria fowleri was not detected in follow-up testing; however, other Naegleria spp. were identified. We postulate that the biofilm in the waterlines may have provided a reservoir for free-living amoebae. The presence/absence of Acanthamoeba and Naegleria spp. did not differ significantly with any measured parameters related to water quality; however, a high percentage of the thermal water pool samples were contaminated with Naegleria or Acanthamoeba. Thus, amoebic contamination may present a serious threat to the health of humans who engage in leisure activities at thermal springs. Copyright © 2013 Australian Society for Parasitology Inc. Published by Elsevier Ltd. All rights reserved.
Attfield, Kathleen R; Dobson, Christine B; Henn, Jennifer B; Acosta, Meileen; Smorodinsky, Svetlana; Wilken, Jason A; Barreau, Tracy; Schreiber, Merritt; Windham, Gayle C; Materna, Barbara L; Roisman, Rachel
2015-09-11
On August 24, 2014, at 3:20 a.m., a magnitude 6.0 earthquake struck California, with its epicenter in Napa County (1). The earthquake was the largest to affect the San Francisco Bay area in 25 years and caused significant damage in Napa and Solano counties, including widespread power outages, five residential fires, and damage to roadways, waterlines, and 1,600 buildings (2). Two deaths resulted (2). On August 25, Napa County Public Health asked the California Department of Public Health (CDPH) for assistance in assessing postdisaster health effects, including earthquake-related injuries and effects on mental health. On September 23, Solano County Public Health requested similar assistance. A household-level Community Assessment for Public Health Emergency Response (CASPER) was conducted for these counties in two cities (Napa, 3 weeks after the earthquake, and Vallejo, 6 weeks after the earthquake). Among households reporting injuries, a substantial proportion (48% in Napa and 37% in western Vallejo) reported that the injuries occurred during the cleanup period, suggesting that increased messaging on safety precautions after a disaster might be needed. One fifth of respondents overall (27% in Napa and 9% in western Vallejo) reported one or more traumatic psychological exposures in their households. These findings were used by Napa County Mental Health to guide immediate-term mental health resource allocations and to conduct public training sessions and education campaigns to support persons with mental health risks following the earthquake. In addition, to promote community resilience and future earthquake preparedness, Napa County Public Health subsequently conducted community events on the earthquake anniversary and provided outreach workers with psychological first aid training.
Trend of Legionella colonization in hospital water supply.
D'Alessandro, D; Fabiani, M; Cerquetani, F; Orsi, G B
2015-01-01
In many nosocomial Legionella outbreaks water distribution systems are the most frequent source of infection. Considering the hospital waterline old age, an investigation on colonization by Legionella spp was carried out in order to evaluate the pipeline system weaknesses and to implement environmental preventive measures. From 2004 to 2010, overall 97 samples from the water line were collected. The samples were analyzed according to the italian Legionella spp standard methods; water temperature, pH and residual free chlorine were determined at the time of collection. X2 test, exact-test and t-test were used to compare proportions and means. Overall 28 samples (23.7%) were positive for Legionella spp, and five of them (17.9%) exceeded the threshold level >104 cfu/L. The number of positive samples varied along the years, showing a significant increasing trend (X2 for trend = 11.5; p<0.01), but most occurred in 2008 (53,6%), when the hospital underwent major building reconstruction. Samples positive for Legionella spp by comparison to negative ones showed a lower free chlorine concentration (0.08 mg/L vs 0.15 mg/L) and a higher water temperature (46.1° vs 42.7°). Actually the percentage of positive samples decreased significantly with the increasing in free chlorine in the water (X2 for trend = 8.53; p<0.01). The samples collected at the connection between public water line with the hospital supply network were always free from Legionella. All hospital buildings were colonized by Legionella spp, although 80% of samples >104 cfu/L occurred in the C-building. No cases of nosocomial legionellosis were reported during the study period. Hospital water system showed a diffuse colonization by Legionella spp, although the degree of contamination reached the threshold level (>104 cfu/L) only in a small percentage of samples, showing a substantial effectiveness of the control measures applied.
NASA Astrophysics Data System (ADS)
Petracco, Marcelo; Camargo, Rita Monteiro; Tardelli, Daniel Teixeira; Turra, Alexander
2014-10-01
The structure, dynamics and production of two populations of the olivid gastropod Olivella minuta were analyzed through monthly sampling from November 2009 through October 2011 on two sandy beaches, Pernambuco (very sheltered) and Barequeçaba (sheltered) in São Paulo state (23°48'S), southeastern Brazil. On both beaches, samples were taken along five transects established perpendicular to the waterline. Parameters of the von Bertalanffy growth function were estimated for both populations from monthly length-frequency distributions. The production and turnover ratios were determined using the mass-specific growth rate method. The population on the less-sheltered Barequeçaba Beach was less abundant (120.02 ± 22.60 ind m-1) than on Pernambuco Beach (3295.30 ± 504.86 ind m-1 (±SE)), which we attribute to the greater environmental stability of the latter. Conversely, the mean length, size of the largest individual, and body mass were higher at Barequeçaba than at Pernambuco. The significant differences in the growth of individuals and the mortality rate (Z) between the beaches suggest that density-dependent processes were operating at Pernambuco Beach. The production and P/B ratio at Pernambuco (12.12 g AFDM m-1 year-1 and 1.91 year-1) were higher than at Barequeçaba (0.82 g AFDM m-1 year-1 and 1.06 year-1). The difference in production can be attributed to the higher abundance on Pernambuco, while the higher P/B ratio resulted from the scarcity of smaller individuals in the intertidal zone of Barequeçaba. The P/B ratio estimated for the Pernambuco population is the highest found so far for sandy-beach gastropods. This study reinforces the theory that biological interactions are important regulators of sheltered sandy-beach populations. Future studies with multi-beach sampling are needed to better understand the life-history variations of O. minuta along gradients of degree of exposure of sandy beaches.
NASA Astrophysics Data System (ADS)
Lea, James; Nick, Faezeh; Benn, Douglas; Kirchner, Nina
2017-04-01
Calving is a major mechanism of cryospheric ice mass loss and a significant contributor to global sea level change, though it is currently poorly understood as a process. Longitudinal strain rate is often cited as a first order control on calving, however multiple different calving laws (not always including the strain rate) have been used to represent this in numerical models of ice sheets. This study seeks to investigate how (1) different calving laws within a 1D flowline model predict strain rate will evolve within increasing terminus thickness for steady state and transient simulations, and (2) how these relationships compare with observed strains (derived from MEaSUREs Greenland InSAR velocity maps; Joughin et al., 2010 [updated 2016]) and depths (from BedMachine v.2 subglacial topography data; Morlighem et al., 2014). We identify that systematic relationships with terminus thickness exist for height above buoyancy, waterline and full-depth crevasse calving laws amongst others for both steady state and transient simulations. However, analysis of observed near-terminus strain rates for multiple Greenlandic glaciers using a variety of metrics (with a range of bed depths predicted by BedMachine) does not reproduce the shape or magnitude of any of these modelled relationships. Relationships between strain rate and depth derived from simple 1D model simulations therefore cannot be realistically compared to current real-world observations. This suggests that the magnitude of observed strain rates at an individual point, or area-averaged conditions near a real-world terminus are not meaningful in determining the potential for calving when taken in isolation. To improve understanding of first/second order calving processes, future modelling work should therefore look to analyse how/if the distribution of strain across the terminus region impacts calving as part of 2D-planform/3D models.
Variation of radiation level and radionuclide enrichment in high background area.
Shetty, P K; Narayana, Y
2010-12-01
Significantly high radiation level and radionuclide concentration along Quilon beach area of coastal Kerala have been reported by several investigators. Detailed gamma radiation level survey was carried out using a portable scintillometer. Detailed studies on radionuclides concentration in different environmental matrices of high background areas were undertaken in the coastal areas of Karunagapalli, Kayankulam, Chavara, Neendakara and Kollam to study the distribution and enrichment of the radionuclides in the region. The absorbed gamma dose rates in air in high background area are in the range 43-17,400nGyh⁻¹. Gamma radiation level is found to be maximum at a distance of 20m from the sea waterline in all beaches. The soil samples collected from different locations were analysed for primordial radionuclides by gamma spectrometry. The activity of primordial radionuclides was determined for the different size fractions of soil to study the enrichment pattern. The highest activity of (232)Th and (226)Ra was found to be enriched in 125-63μ size fraction. The preferential accumulation of (40)K was found in <63μ fraction. The minimum (232)Th activity was 30.2Bqkg⁻¹, found in 1000-500μ particle size fraction at Kollam and maximum activity of 3250.4Bqkg⁻¹ was observed in grains of size 125-63μ at Neendakara. The lowest (226)Ra activity observed was 33.9Bqkg⁻¹ at Neendakara in grains of size 1000-500μ and the highest activity observed was 482.6Bqkg⁻¹ in grains of size 125-63μ in Neendakara. The highest (40)K activity found was 1923Bqkg⁻¹ in grains of size <63μ for a sample collected from Neendakara. A good correlation was observed between computed dose and measured dose in air. The correlation between (232)Th and (226)Ra was also moderately high. The results of these investigations are presented and discussed in this paper. Copyright © 2010 Elsevier Ltd. All rights reserved.
Rando, Roy J; Kwon, Cheol-Woong; Lefante, John J
2014-01-01
In the aftermath of Hurricane Katrina, which devastated the city of New Orleans in August 2005, restoration workers were at risk for respiratory illness from exposure to airborne particles and microbial agents. In support of an epidemiologic investigation of this risk, an exposure assessment for restoration work activities (demolition, trash & debris management, landscape restoration, sewer/waterline repair, and mold remediation) was performed from 2005 to 2012. For 2005 and 2006, Occupational Safety and Health Administration (OSHA) data (n = 730) for personal and area monitoring of total and respirable dust exposures of restoration workers were accessed and analyzed. The most significant exposures were for demolition work, with average respirable dust exposures in 2005 above the action level of 2.5 mg/m(3) and 17.6% of exposures exceeding the permissible exposure limit (PEL) (5 mg/m(3)). Additional personal and area monitoring for thoracic particulate matter was performed from 2007 to 2012 (n = 774) and samples were assayed for endotoxin and (1→3, 1→6)-β-D-glucan (n = 202). In order to integrate the OSHA data with the later monitoring data, three independent predictive models were developed to convert total and respirable dust measures into the equivalent thoracic dust. The three models were not statistically different and the modeling results were in good agreement with an overall coefficient of variation of 16% for the thoracic dust means across work activities estimated by each of the three models. Overall, thoracic dust exposure levels decreased by about an order of magnitude within the first year after Katrina and then more gradually declined and stabilized through 2012. Estimated average exposures to endotoxin and microbial glucan in 2005 were as high as 256 EU/m(3) and 118 μg/m(3), respectively, and likewise were seen to decrease dramatically and stabilize after 2005. The results of this exposure assessment support previously published reports of respiratory illness including sinusitis, toxic pneumonitis, and Katrina Cough among restoration workers in the years immediately after the hurricane.
Cavaillé, Paul; Ducasse, Léon; Breton, Vincent; Dommanget, Fanny; Tabacchi, Eric; Evette, André
2015-03-15
Erosion control is a major issue in the Prealps region since piedmont is subject to both intense flood hazards and anthropic pressure. Riverbank protections may have major impacts on local ecosystem functioning and ecological corridor continuity. This study aimed to estimate the effects of the types of riverbank protection technique (from pure riprap to pure bioengineering) on the taxonomic and ecological composition of plant communities in comparison with unmanaged riverbanks as the referential system. Thirty-eight embankments were sampled in the foothills of the French and Swiss Alps. Four distinct riverbank techniques were analyzed and natural young willow stands were chosen as the referential system. At each site, vegetation was sampled along three transects from the waterline to the top of the riverbank. Plant communities were characterized using biological group composition (growth forms and life history, life strategies and distribution in space and time) and functional diversity indices (MFAD, FDc and wFDc). We identified 177 distinct plant species on 38 sites. Higher species richness levels were observed on bioengineered banks (from an average of 12 species recorded on ripraps to 27 species recorded on bioengineered banks) strongly dominated by Salicaceae species, especially for fascine and cribwall banks. Functional analyses of plant communities highlighted significant differences among bank types (p-value: 0.001) for all selected biological groups. Competitive - ruderal strategy, rooting shoots, stems or leaves that lie down or break off, and unisexual - dioecious, as well as pioneer plants and low shrubs (<4 m tall) distinguished bioengineered bank types. Functional diversity indices confirmed these differences among bank types (MFAD: p-value: 0.002; FDc: p-value: 0.003; wFDc: p-value: 0.005). Riprap always showed the lowest levels on functional diversity indices, fascine and cribwall banks were at the medium level and finally mixed and natural banks the highest level. These results confirm the low ecological potential of purely hard engineering techniques and highlight the similarity of bioengineered techniques and unmanaged riverbanks. Copyright © 2014 Elsevier Ltd. All rights reserved.
Adaptation to Impacts of Greenhouse Gases on the Ocean (Invited)
NASA Astrophysics Data System (ADS)
Caldeira, K.
2010-12-01
Greenhouse gases are producing changes in ocean temperature and circulation, and these changes are already adversely affecting marine biota. Furthermore, carbon dioxide is absorbed by the oceans from the atmosphere, and this too is already adversely affecting some marine ecosystems. And, of course, sea-level rise affects both what is above and below the waterline. Clearly, the most effective approach to limit the negative impacts of climate change and acidification on the marine environment is to greatly diminish the rate of greenhouse gas emissions. However, there are other measures that can be taken to limit some of the negative effects of these stresses in the marine environment. Marine ecosystems are subject to multiple stresses, including overfishing, pollution, and loss of coastal wetlands that often serve as nurseries for the open ocean. The adaptive capacity of marine environments can be improved by limiting these other stresses. If current carbon dioxide emission trends continue, for some cases (e.g., coral reefs), it is possible that no amount of reduction in other stresses can offset the increase in stresses posed by warming and acidification. For other cases (e.g., blue-water top-predator fisheries), better fisheries management might yield improved population health despite continued warming and acidification. In addition to reducing stresses so as to improve the adaptive capacity of marine ecosystems, there is also the issue of adaptation in human communities that depend on this changing marine environment. For example, communities that depend on services provided by coral reefs may need to locate alternative foundations for their economies. The fishery industry will need to adapt to changes in fish abundance, timing and location. Most of the things we would like to do to increase the adaptive capacity of marine ecosystems (e.g., reduce fishing pressure, reduce coastal pollution, preserve coastal wetlands) are things that would make sense to do even in the absence of threats from climate change and ocean acidification. Therefore, these measures represent “no regrets” policy options for the marine environment. Nevertheless, even with adaptive policies in place, continued greenhouse gas emissions increasingly risk damaging marine ecosystems and the human communities that depend on them.
Project FLOSSIE: Marine Data Stewardship at the Waterline
NASA Astrophysics Data System (ADS)
Bouchard, R. H.; Jensen, R. E.; Riley, R. E.
2016-02-01
There are more than 10 million wave records from platforms of the National Data Buoy Center (NDBC) that are archived by National Oceanic and Atmospheric Administration (NOAA). A considerable number of these were measured from the 61 NOMAD (Navy Oceanographic Meteorological Automatic Device) hulls that NDBC has used to make wave measurements since October 1979. Many of these measurements were made before the era of modern marine data stewardship. These long records lend themselves to investigations of climate trends and variability either directly by the measurements themselves, or indirectly by validating long-term numerical wave models or remote sensing applications. However studies (e.g., Gemmrich et al. 2011) indicate that discontinuities and increased variability of the measurements can arise from changing wave systems and platforms. The value of these records is undermined by the lack of understanding or documentation of technology changes - a critical component of data stewardship. To support its mission of long-term understanding of coastal waves and wave models, the U.S. Army Corps of Engineers, Coastal Hydraulics Laboratory (CHL) sponsored the FLOSSIE Project to gage the effects of technology changes on the long-term wave measurements from NOMAD hulls. On behalf of CHL, NDBC engineering and operations integrated old, new, and leading edge technologies on one NOMAD hull. The hull was successfully deployed in July 2015 at the Wave Evaluation and Testing area off of Monterey Bay, CA. The area hosts an NDBC 3-m hull with cross-generational-technologies and a reference standard in a Datawell Waverider buoy. Thus cross-generational and cross-platform inter-comparisons can be performed simultaneously to an accepted standard. The analysis goes beyond the bulk wave parameters. The analysis will examine the energy and directional distributions over the frequency range of wind-generated waves. The project is named in honor of the pioneering World War II Naval meteorologist, Commander Florence (Flossie) Van Straten (1913 - 1992), USNR, who coined the acronym for NOMAD. This paper will discuss the goals of the project, present preliminary data results and application to the long-term measurements, and outline the plans incorporating Best Practices of Marine Data Stewardship for the resulting datasets.
NASA Astrophysics Data System (ADS)
Lee, Yoon-Kyung; Choi, Jong-Kuk; Ryu, Joo-Hyung; Eom, Jinah
2014-05-01
Tidal flats are valuable ecosystem by a productive flora and fauna which support large populations of birds, form nursery and feeding areas for coastal fisheries, provide intrinsic values such as aesthetics and education (Costanza et al., 1997; Goodwin et al., 2001). The half of the world's coastal wetlands will submerge during this century in response to sea level rise although salt marsh has a capacity to adjust to sea level rise change. However, tidal flats have been changed because of several coastal construction projects that had not been considered sustainable over the last 30 years in Korean Peninsula. The total area of tidal flats decreased from approximately 2,800 km2 in 1990 to 2,393 km2 in 2005 due to the land reclamations and dredging in South Korea. Many researchers investigated topography, sedimentation changes and local hydrodynamics for this area in the early 1990s. However, they are limited to the temporal and spatial scale because field surveys in the tidal flats are restricted due to the difficulties in accessing. The aim of this study was to examine environmental change in tidal flat in a large scale for long-term based on the remotely sensed data as well as in situ measurements. This study focused on the tidal flat that not only had been affected by reclamations on a large scale such as Ganghwa and Saemangeum but also had been indirectly affected by reclamations such as Hwang-do and Gomso-bay. In this study, changes in morphology and sedimentary facies in tidal flats were estimated. Digital elevation models (DEMs) in early 2000 and 2010 were generated based on the Landsat TM/ETM+ images using a waterline method. Morphological change was estimated based on the differences of DEMs and sedimentary facies was investigated based on the calculation of image-derived PCA coefficient. Results of the morphological change in tidal flats interestingly showed that large amount of areas had been deposited whereas the other areas were eroded. Area with deposited tendency showed increase in fine sediments whereas area with eroded tendency showed increase in coarse sediments. This result was compared with the tidal current speed estimated from a hydrological model.
Remotely sensed evidence of the rapid loss of tidal flats in the Yellow Sea
NASA Astrophysics Data System (ADS)
Murray, N. J.; Phinn, S. R.; Clemens, R. S.; Possingham, H.; Fuller, R. A.
2013-12-01
In East Asia's Yellow Sea, intertidal wetlands are the frontline ecosystem protecting a coastal population of more than 150 million people from storms and sea-level rise. Despite widespread coastal change and severe modification of the region's major river systems, the magnitude and distribution of coastal wetland loss remains unquantified. We developed a novel remote sensing method to solve the difficult problem of mapping intertidal wetlands over large areas and mapped the extent of tidal flats, the region's primary coastal ecosystem, over 4000kms of coastline at two time periods: the 1980s and late 2000s. We used a regionally validated tide model to identify Landsat images acquired at high and low tides, allowing the area between the high and low tide waterlines to be mapped by differencing classified land-water images between the two tidal stages. Our analysis of the change in areal extent of tidal flats in the Yellow Sea indicates that of the 545,000 ha present in the 1980s, only 389,000 ha remained three decades later, equating to a net loss of 28% at a mean rate of 1.2 % yr-1. ). Comparing the three countries in our analysis, China lost more tidal flat and at a faster rate (39.8%, 1.8% yr-1) than South Korea (32.2%, 1.6% yr-1), and in North Korea minor gains of tidal flat were recorded at (8.5%, 0.3 yr-1). For the same mapped area, historical maps suggest that tidal flats occupied up to 1.14 million ha in the mid-1950s, equating to a potential net loss of up to 65% over ~50 years. Coastal land reclamation for agriculture, aquaculture and urban development is a major driver of tidal flat loss, particularly in China and South Korea, although region-wide declines in sediment replenishment from rivers is also occurring. To conserve the ecosystem services provided by tidal flats and ensure protection of the region's coastal biodiversity, conservation actions should target protection of tidal flats and encourage collaborative and properly planned development strategies. Tidal flat conversion to agricultural land in Chungcheongnam-do Province, South Korea (1982, 2010). The Landsat MSS and TM images show widespread conversion of tidal flats (left) to agricultural land (right) over two decades.
NASA Astrophysics Data System (ADS)
Rohmer, Jeremy; Idier, Deborah; Bulteau, Thomas; Paris, François
2016-04-01
From a risk management perspective, it can be of high interest to identify the critical set of offshore conditions that lead to inundation on key assets for the studied territory (e.g., assembly points, evacuation routes, hospitals, etc.). This inverse approach of risk assessment (Idier et al., NHESS, 2013) can be of primary importance either for the estimation of the coastal flood hazard return period or for constraining the early warning networks based on hydro-meteorological forecast or observations. However, full-process based models for coastal flooding simulation have very large computational time cost (typically of several hours), which often limits the analysis to a few scenarios. Recently, it has been shown that meta-modelling approaches can efficiently handle this difficulty (e.g., Rohmer & Idier, NHESS, 2012). Yet, the full-process based models are expected to present strong non-linearities (non-regularities) or shocks (discontinuities), i.e. dynamics controlled by thresholds. For instance, in case of coastal defense, the dynamics is characterized first by a linear behavior of the waterline position (increase with increasing offshore conditions), as long as there is no overtopping, and then by a very strong increase (as soon as the offshore conditions are energetic enough to lead to wave overtopping, and then overflow). Such behavior might make the training phase of the meta-model very tedious. In the present study, we propose to explore the feasibility of active learning techniques, aka semi-supervised machine learning, to track the set of critical conditions with a reduced number of long-running simulations. The basic idea relies on identifying the simulation scenarios which should both reduce the meta-model error and improve the prediction of the critical contour of interest. To overcome the afore-described difficulty related to non-regularity, we rely on Support Vector Machines, which have shown very high performance for structural reliability assessment. The developments are done on a cross-shore case, using the process-based SWASH model. The related computational time is 10 hours for a single run. The dynamic forcing conditions are parametrized by several factors (storm surge S, significant wave height Hs, dephasing between tide and surge, etc.). In particular, we validated the approach with respect to a reference set of 400 long-running simulations in the domain of (S ; Hs). Our tests showed that the tracking of the critical contour can be achieved with a reasonable number of long-running simulations of a few tens.
Savvichev, A S; Rusanov, I I; Iusupov, S K; Baĭramov, I T; Pimenov, N V; Lein, A Iu; Ivanov, M V
2003-01-01
Microbiological and biogeochemical investigations of the coastal zone and the littoral of the Kandalaksha Bay of the White Sea were carried out. The material for investigations was obtained in the series of expeditions of the Institute of Microbiology, Russian Academy of Sciences, in August 1999, 2000, 2001, and in March 2003. The studies were conducted on the littoral and in the water area of the Kandalaksha Preserve, the Moscow University Belomorsk Biological Station, and the Zoological Institute Biological Station, Russian Academy of Sciences, Sediment sampling on the littoral was carried out in the typical microlandscapes differing in the sediment properties and macrobenthos distribution. The maximal sulfate reduction rate (SRR) was shown for the shallow part of the Chemorechenskaya Bay (up to 2550 micrograms S/(dm3 day)) and in the Bab'ye More Bay (up to 3191 micrograms S/(dm3 day)). During the winter season, at a temperature of -0.5-0.5 degrees C, the SRR in the sediments of the Kartesh Bay was 7.9-13 micrograms S/(dm3 day). In the widest limits, the SRR values varied in the sediment cores sampled on the littoral. The minimal values (11 mu]g S/(dm3 day)) were obtained in the core samples on the silt-sandy littoral. The littoral finely dispersed sediments rich in organic matter were characterized by high SRR values (524-1413 micrograms S/(dm3 day)). The maximal SRR values were shown for the sediments present within the stretch of decomposing macrophytes, in local pits at the lower littoral waterline, and in the mouth of a freshwater stream (51-159 mg S/(dm3 day)). A sharp difference in the level of H2S production in the type microlandscapes was shown. The average hydrogen sulfide production in finely dispersed sediments constituted 125 mg S/(m2 day); in stormy discharge deposits, 1950 mg S/(m2 day); in depressions under stones and in silted pits, 4300 mg S/(m2 day). A calculation made with regard to the area of microlandscapes with increased productivity shows that the daily H2S production per 1 km2 of the littoral (August) is 60.8 to 202 kg S/(km2 day), while the organic carbon consumption for sulfate reduction per 1 km2 of the littoral is 46 to 152 kg C(org)/(km2 day).
A Novel Approach to Mapping Intertidal Areas Using Shore-Based X-band Marine Radar
NASA Astrophysics Data System (ADS)
Bird, Cai; Bell, Paul
2014-05-01
Monitoring the morphology of coastal zones in response to high energy weather events and changing patterns of erosion and deposition over time is vital in enabling effective decision-making at the coast. Common methods of mapping intertidal bathymetry currently include vessel-based sonar and airborne LiDAR surveys, which are expensive and thus not routinely collected on a continuous basis. Marine radar is a ubiquitous technology in the marine industry and many ports operate a system to guide ships into port, this work aims to utilise this already existing infrastructure to determine bathymetry over large intertidal areas, currently up to 4 km from the radar. Standard X-band navigational radar has been used in the marine industry to measure hydrodynamics and derive bathymetry using empirical techniques for several decades. Methods of depth mapping thus far have relied on the electromagnetic backscattering from wind-roughened water surface, which allows a radar to gather sea surface image data but requires the waves to be clearly defined. The work presented here does not rely on identifying and measuring these spatial wave features, which increases the robustness of the method. Image data collected by a 9.4Ghz Kelvin Hughes radar from a weather station on Hilbre Island at the mouth of the River Dee estuary, UK were used in the development of this method. Image intensity at each pixel is a function of returned electromagnetic energy, which in turn can be related to the roughness of the sea surface. Images collected over time periods of 30 minutes show general patterns of wave breaking and mark the advance and retreat of the waterline in accordance with the tidal cycle and intertidal morphology. Each pixel value can be extracted from these mean images and analysed over the course of several days, giving a fluctuating time series of pixel intensity, the gradient of which gives a series of pulses representing transitions between wet and dry at each location. A tidal elevation record collected from a gauge at the Island is used to generate a similar series of pulses for each elevation above chart datum. A matching algorithm compares these pulse sequences at each tide level and determines a bed elevation value for each pixel location. Values derived have a maximum error of 1 m when compared to a LiDAR survey of the area during the same time period. Refinements of this technique could form the basis of a long-term automated monitoring system for the morphology of intertidal coastal areas allowing varying scales of sedimentary features to be tracked. This may allow the optimisation of maintenance dredging and quantify the effects of beach nourishment and capital dredging along a shoreline.
Jagucki, Martha L.; Bexfield, Laura M.; Heywood, Charles E.; Eberts, Sandra M.
2012-01-01
This fact sheet highlights findings from the vulnerability study of a public-supply well in Albuquerque, New Mexico (hereafter referred to as “the study well”). The study well produces about 3,000 gallons of water per minute from the Rio Grande aquifer system. Water samples were collected at the study well, at two other nearby public-supply wells, and at monitoring wells installed in or near the simulated zone of contribution to the study well. Untreated water samples from the study well contained arsenic at concentrations exceeding the Maximum Contaminant Level (MCL) of 10 micrograms per liter (µg/L) established by the U.S. Environmental Protection Agency for drinking water. Volatile organic compounds (VOCs) and nitrate also were detected, although at concentrations at least an order of magnitude less than established drinking-water standards, where such standards exist. Overall, study findings point to four primary influences on the movement and (or) fate of contaminants and the vulnerability of the public-supply well in Albuquerque: (1) groundwater age (how long ago water entered, or recharged, the aquifer), (2) groundwater development (introduction of manmade recharge and discharge sources), (3) natural geochemical conditions of the aquifer, and (4) seasonal pumping stresses. Concentrations of the isotope carbon-14 indicate that groundwater from most sampled wells in the local study area is predominantly water that entered, or recharged, the aquifer more than 6,000 years ago. However, the additional presence of the age tracer tritium in several groundwater samples at concentrations above 0.3 tritium units indicates that young (post-1950) recharge is reaching the aquifer across broad areas beneath Albuquerque. This young recharge is mixing with the thousands-of-years-old water, is migrating to depths as great as 245 feet below the water table, and is traveling to some (but not all) of the public-supply wells sampled. Most groundwater samples containing a fraction of young water also contain manmade VOCs, including chloroform (a byproduct of drinking-water chlorination), which indicates that the source of young recharge is, at least in part, infiltration of chlorinated municipal-supply water from leaking waterlines and sewerlines or from turf watering. Other likely manmade, urban recharge sources are seepage from constructed ponds and unlined portions of a stormwater diversion channel. A regional-scale computer-model simulation of groundwater flow and transport to the public-supply well shows that manmade sources of recharge and discharge that were added after about 1930 have greatly altered directions of groundwater flow near Albuquerque and have caused water levels to decline by as much as 120 feet. Local-scale simulations show that seasonal changes in the pumping schedule of the study well affect the age and quality of water produced by the well. Increased pumping during the summer causes significant volumes of water to flow downward from the shallow to the intermediate zones of the aquifer, causing a higher fraction of young water to be produced by the well in the summer than in the winter months and a corresponding increase in VOC detections in the summer relative to the winter. During the winter when the study-well pump is idle for several hours each day, old, high-arsenic water from the deep zone of the aquifer travels up the wellbore and exits into the intermediate zone of the aquifer. When the pump is activated in the winter (for a relatively short time each day), some of the leaked, high-arsenic water is recaptured by the well. This results in a higher arsenic concentration (commonly more than 12 µg/L) in water produced in the winter than in the summer, and a smaller fraction of young water being produced by the well in the winter than in the summer (6 percent in the winter, compared to 11 percent in the summer). Knowledge of the vertical flow direction (both natural and pumping-enhanced) in the vicinity of a long-screened well, coupled with understanding of variations in contaminant concentrations with depth in the aquifer, can help water managers predict the positive or negative effect that wellbore flow will have on water quality and can lead to development of strategies to mitigate contamination (such as changes in pumping schedules or development of devices to inhibit wellbore flow when the pump is off).
Short and long-term thermo-erosion of ice-rich permafrost coasts in the Laptev Sea region
NASA Astrophysics Data System (ADS)
Günther, F.; Overduin, P. P.; Sandakov, A. V.; Grosse, G.; Grigoriev, M. N.
2013-02-01
Permafrost coasts in the Arctic are susceptible to a variety of changing environmental factors all of which currently point to increasing coastal erosion rates and mass fluxes of sediment and carbon to the shallow arctic shelf seas. Rapid erosion along high yedoma coasts composed of Ice Complex permafrost deposits creates impressive coastal ice cliffs and inspired research for designing and implementing change detection studies for a long time, but continuous quantitative monitoring and a qualitative inventory of coastal thermo-erosion for large coastline segments is still lacking. Our goal is to use observations of thermo-erosion along the mainland coast of the Laptev Sea in eastern Siberia to understand how erosion rates depend on coastal geomorphology and the relative contributions of waterline and atmospheric drivers to coastal thermo-erosion over the past 4 decades and in the past few years. We compared multitemporal sets of orthorectified satellite imagery from 1965 to 2011 for three segments of coastline with a length of 73 to 95 km each and analyzed thermo-denudation (TD) along cliff top and thermo-abrasion (TA) along cliff bottom for two nested time periods: long-term rates (the past 39-43 yr) and short term rates (the past 1-3 yr). The Normalized Difference Thermo-erosion Index (NDTI) was used as a proxy that qualitatively describes the relative proportions of TD and TA. Mean annual erosion rates at all three sites were higher in recent years (-5.3 ± 1.31 m a-1) than over the long term mean (-2.2 ± 0.13 m a-1). The Mamontov Klyk coast exhibit primarily spatial variations of thermo-erosion, while intrasite-specific variations were strongest at the Buor Khaya coast, where slowest long-term rates around -0.5 ± 0.08 m a-1 were observed. The Oyogos Yar coast showed continuously rapid erosion up to -6.5 ± 0.19 m a-1. In general, variable characteristics of coastal thermo-erosion were observed not only between study sites and over time, but also within single coastal transects along the cliff profile. Varying intensities of cliff bottom and top retreat are leading to diverse qualities of coastal erosion that have different impacts on coastal mass fluxes. The different extents of Ice Complex permafrost degradation within our study sites turned out to influence not only the degree of coupling between TD and TA, and the magnitude of effectively eroded volumes, but also the quantity of organic carbon released to the shallow Laptev Sea from coastal erosion, which ranged on a long-term from 88 ± 21.0 to 800 ± 61.1 t per km coastline per year and will correspond to considerably higher amounts, if recently observed more rapid coastal erosion rates prove to be persistent.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karr, Dale G.; Yu, Bingbin; Sirnivas, Senu
To create long-term solutions for offshore wind turbines in a variety of environmental conditions, CAE tools are needed to model the design-driving loads that interact with an offshore wind turbine system during operation. This report describes our efforts in augmenting existing CAE tools used for offshore wind turbine analysis with a new module that can provide simulation capabilities for ice loading on the system. This augmentation was accomplished by creating an ice-loading module coupled to FAST8, the CAE tool maintained by the NREL for simulating land-based and offshore wind turbine dynamics. The new module includes both static and dynamic icemore » loading that can be applied during a dynamic simulation of the response of an offshore wind turbine. The ice forces can be prescribed, or influenced by the structure’s compliant response, or by the dynamics of both the structure and the ice floe. The new module covers ice failure modes of spalling, buckling, crushing, splitting, and bending. The supporting structure of wind turbines can be modeled as a vertical or sloping form at the waterline. The Inward Battered Guide Structure (IBGS) foundation designed by Keystone Engineering for the Great Lakes was used to study the ice models coupled to FAST8. The IBGS foundation ice loading simulations in FAST8 were compared to the baseline simulation case without ice loading. The ice conditions reflecting those from Lake Huron at Port Huron and Lake Michigan at North Manitou were studied under near rated wind speed of 12 m/s for the NREL 5-MW reference turbine. Simulations were performed on ice loading models 1 through 4 and ice model 6 with their respective sub-models. The purpose of ice model 5 is to investigate ice loading on sloping structures such as ice-cones on a monopile and is not suitable for multi-membered jacketed structures like the IBGS foundation. The key response parameters from the simulations, shear forces and moments from the tower base and IBGS foundation base, were compared. Ice models 1 and 6 do not significantly affect the tower fore-aft shear and moment. However, ice model 2 (dynamic analyses), model 3 (random ice loading), and model 4 (multiple ice failure zone loading) show increased effect on the tower fore-aft shear and moment with significant effect from ice model 3.1. In general ice loading creates large reaction forces and moments at the base of the IBGS foundation; the largest occurred in model 1.1 (steady creep ice indentation loading) followed by model 3.1 (random creep ice indentation loading). In general the power production from the ice loading cases had little deviation from the baseline case without ice loading. For ultimate limit state (ULS), ice model 1.1 ice and 3.1 appear to be the ice most critical models to consider at an early stage of design. Ice model 4 is an important tool for assessing structural fatigue.« less
Dental Assistant. Health Occupations Education.
ERIC Educational Resources Information Center
Hefner, Dollie
This curriculum is comprised of 31 instructional units divided into eight subject areas: orientation (6 units), anatomy and physiology (6 units), dental histology (1 unit), microbiology and bacteriology (2 units), pharmacology (2 units), chairside assistance (9 units), roentgenology (2 units), and practice administration (3 units). Each…
NASA Astrophysics Data System (ADS)
Kadereit, Annette; Dewitt, Regina; Terrazas, Alejandro; Stinnesbeck, Wolfgang; Zipf, Lars; Schukraft, Gerd
2017-04-01
Lake Chapala in the central-western Mexican state of Jalisco is the successor of the late-Miocene to early Pleistocene palaeo-lake Jalisco and is situated in an active neotectonic basin at approximately 1500 m above sea level. It presently covers an area of ca. 1100 km2 and represents Mexico's largest freshwater reservoir. As water depth reaches only a few meters the position of its shorelines has fluctuated substantially throughout the lake's history due to volcanic and tectonic activity as well as climate fluctuations. One of the more recently abandoned shorelines is preserved on the northern shoreline east of Ajijic at San Antonio Tlayacapan (SAT), where sand and silt deposits crop out at the present waterline. The beach sediments at SAT are famous for their fossils of late Wisconsian age (e.g. ground sloths, gomphotheriids), but also host human osteological remains, which are now housed in the Museo de Paleontología de Guadalajara, in the state capital. Numeric dating of sediments from Lake Chapala has proven to be exceedingly difficult as bones are heavily mineralized by Fe-Mn-oxides. In addition, input of ancient carbon exists from hydrothermal sources deep underneath the lake bottom and its distribution throughout the lake-water body, with currents driven by easterly winds and respective counter-currents, leading to age inversions for 14C-dating (Zárate-del-Valle et al. 2011). As 14C radiometric methods are thus shown to be problematic we here tested the possibility of optical stimulated luminescence (OSL) dating. Diverse tests showed that the samples were not adequate for coarse-grain quartz dating or post infrared stimulated (post-IR) blue-light stimulated (BLSL) dating of polymineral fine grains. The blue emission band of the infrared stimulated luminescence (IRSL) signal of the natural samples has been proven to be quite dim, so that a single aliquot regeneration (SAR) protocol (Murray & Wintle 2000) was not suitable. Finally, we applied a traditional multi-aliquot additive (MAA) IRSL (blue) protocol to polymineral fine grains (4 - 11 µm) extracted from the sediment. This produced late glacial to early Holocene ages for the three SAT samples. Although the ages bear uncertainties, e.g. with respect to the samples' a-values and the possible variation of water content of the sediment over the dating period, to our knowledge they represent the first numeric ages for the fossil-bearing deposit. Our positive tests thus encourage us to use the results of the luminescence dating to narrow down the chronological placement of the fossil sites in the Chapala lake shoreface to late glacial to early Holocene times. Murray, A.S. & Wintle, A.G. (2000): Luminescence dating of quartz using an improved single aliquot regenerative-dose protocol.- Radiation Measurements 32: 57-73. Zápate-del-Valle, P.F., Ramírez-Sánchez, H.U., Fernex, F., Simoneit, B.R.T., Israde-Alcántara, I. (2011): Radiocarbon age inversions and progression: source and causes in Late Holocene sediments from Lake Chapala, western Mexico.- Environmental Earth Sciences 63:1011-1019.
MP3 - A Meteorology and Physical Properties Package to explore Air:Sea interaction on Titan
NASA Astrophysics Data System (ADS)
Lorenz, R. D.
2012-04-01
The exchange of mass, heat and momentum at the air:sea interface are profound influences on our environment. Titan presents us with an opportunity to study these processes in a novel physical context. The MP3 instrument, under development for the proposed Discovery mission TiME (Titan Mare Explorer) is an integrated suite of small, simple sensors that combines the a traditional meteorology package with liquid physical properties and depth-sounding. In TiME's 6-Titan-day (96-day) nominal mission, MP3 will have an extended measurement opportunity in one of the most evocative environments in the solar system. The mission and instrument benefit from APL's expertise and experience in marine as well as space systems. The topside meteorology sensors (METH, WIND, PRES, TEMP) will yield the first long-duration in-situ data to constrain Global Circulation Models. The sea sensors (TEMP, TURB, DIEL, SOSO) allow high cadence bulk composition measurements to detect heterogeneities as the TiME capsule drifts across Ligeia, while a depth sounder (SONR) will measure the bottom profile. The combination of these sensors (and vehicle dynamics, ACCL) will characterize air:sea exchange. In addition to surface data, a measurement subset (ACCL, PRES, METH, TEMP) is made during descent to characterize the structure of the polar troposphere and marine boundary layer. A single electronics box inside the vehicle performs supervising and data handling functions and is connected to the sensors on the exterior via a wire and fiber optic harness. ACCL: MEMS accelerometers and angular rate sensors measure the vehicle motion during descent and on the surface, to recover wave amplitude and period and to correct wind measurements for vehicle motion. TEMP: Precision sensors are installed at several locations above and below the 'waterline' to measure air and sea temperatures. Installation of topside sensors at several locations ensures that at least one is on the upwind side of the vehicle. PRES: The barometer subsystem uses pressure sensors from FMI of the type flown on Huygens. METH. Methane humidity (and the presence of fog) is measured with a near-IR differential absorption spectro-photometer. The humidity may vary with and fetch, as well as on nearby rainfall. WIND. An ultrasonic anemometer, mounted on a mast to minimize flow perturbations, measures wind speed and direction. DIEL : An immersed parallel-plate capacitor (spare from Huygens SSP) fills with liquid to measure the dielectric constant. This is sensitive to the methane/ethane ratio, and to the possible presence of nitriles such as HCN. SOSO : A pair of ultrasound transducers (SSP spares) measure the speed of sound in the liquid, a function of the methane/ethane ratio (unaffected by trace nitriles). SONR : A down-looking piezoelectric depth-sounder to measure the bottom profile. The echo record will also indicate suspended scatterers and the presence of bubble noise at the sea surface. TURB. A visible light beam is passed through the liquid and the direct and scattered intensity is measured to gauge particles in the liquid and the deposition of solar heat with depth.
31 CFR 515.321 - United States; continental United States.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 31 Money and Finance:Treasury 3 2013-07-01 2013-07-01 false United States; continental United... General Definitions § 515.321 United States; continental United States. The term United States means the United States and all areas under the jurisdiction or authority thereof, including the Trust Territory of...
31 CFR 535.321 - United States; continental United States.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 31 Money and Finance:Treasury 3 2011-07-01 2011-07-01 false United States; continental United... General Definitions § 535.321 United States; continental United States. The term United States means the United States and all areas under the jurisdiction or authority thereof including the Trust Territory of...
31 CFR 535.321 - United States; continental United States.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 31 Money and Finance:Treasury 3 2013-07-01 2013-07-01 false United States; continental United... General Definitions § 535.321 United States; continental United States. The term United States means the United States and all areas under the jurisdiction or authority thereof including the Trust Territory of...
31 CFR 535.321 - United States; continental United States.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States; continental United... General Definitions § 535.321 United States; continental United States. The term United States means the United States and all areas under the jurisdiction or authority thereof including the Trust Territory of...
31 CFR 515.321 - United States; continental United States.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States; continental United... General Definitions § 515.321 United States; continental United States. The term United States means the United States and all areas under the jurisdiction or authority thereof, including the Trust Territory of...
31 CFR 515.321 - United States; continental United States.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 31 Money and Finance:Treasury 3 2014-07-01 2014-07-01 false United States; continental United... General Definitions § 515.321 United States; continental United States. The term United States means the United States and all areas under the jurisdiction or authority thereof, including the Trust Territory of...
31 CFR 500.321 - United States; continental United States.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States; continental United... General Definitions § 500.321 United States; continental United States. The term United States means the United States and all areas under the jurisdiction or authority thereof, including U.S. trust territories...
31 CFR 515.321 - United States; continental United States.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 31 Money and Finance:Treasury 3 2011-07-01 2011-07-01 false United States; continental United... General Definitions § 515.321 United States; continental United States. The term United States means the United States and all areas under the jurisdiction or authority thereof, including the Trust Territory of...
31 CFR 535.321 - United States; continental United States.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 31 Money and Finance:Treasury 3 2012-07-01 2012-07-01 false United States; continental United... General Definitions § 535.321 United States; continental United States. The term United States means the United States and all areas under the jurisdiction or authority thereof including the Trust Territory of...
31 CFR 535.321 - United States; continental United States.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 31 Money and Finance:Treasury 3 2014-07-01 2014-07-01 false United States; continental United... General Definitions § 535.321 United States; continental United States. The term United States means the United States and all areas under the jurisdiction or authority thereof including the Trust Territory of...
31 CFR 515.321 - United States; continental United States.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 31 Money and Finance:Treasury 3 2012-07-01 2012-07-01 false United States; continental United... General Definitions § 515.321 United States; continental United States. The term United States means the United States and all areas under the jurisdiction or authority thereof, including the Trust Territory of...
40 CFR 63.1568 - What are my requirements for HAP emissions from sulfur recovery units?
Code of Federal Regulations, 2012 CFR
2012-07-01
... emissions from sulfur recovery units? 63.1568 Section 63.1568 Protection of Environment ENVIRONMENTAL... Petroleum Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Catalytic Cracking Units, Catalytic Reforming Units, Sulfur Recovery Units, and Bypass Lines § 63.1568 What...
40 CFR 63.1566 - What are my requirements for organic HAP emissions from catalytic reforming units?
Code of Federal Regulations, 2011 CFR
2011-07-01
... Petroleum Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Catalytic Cracking Units, Catalytic Reforming Units, Sulfur Recovery Units, and Bypass Lines § 63.1566 What...
Wijmans, Johannes G [Menlo Park, CA; Merkel, Timothy C [Menlo Park, CA; Baker, Richard W [Palo Alto, CA
2011-10-11
Disclosed herein are combustion systems and power plants that incorporate sweep-based membrane separation units to remove carbon dioxide from combustion gases. In its most basic embodiment, the invention is a combustion system that includes three discrete units: a combustion unit, a carbon dioxide capture unit, and a sweep-based membrane separation unit. In a preferred embodiment, the invention is a power plant including a combustion unit, a power generation system, a carbon dioxide capture unit, and a sweep-based membrane separation unit. In both of these embodiments, the carbon dioxide capture unit and the sweep-based membrane separation unit are configured to be operated in parallel, by which we mean that each unit is adapted to receive exhaust gases from the combustion unit without such gases first passing through the other unit.
ERIC Educational Resources Information Center
Houlihan, Christina; McLeod, Shannon
This curriculum unit and 1-hour videotape are designed to help students understand the purpose and functions of the United Nations (UN) and explore the relationship between the United Nations and the United States. The UN's role in the global counterterrorism campaign serves as a case study for the unit. The students are asked to develop a basic…
Comprehensive stroke units: a review of comparative evidence and experience.
Chan, Daniel K Y; Cordato, Dennis; O'Rourke, Fintan; Chan, Daniel L; Pollack, Michael; Middleton, Sandy; Levi, Chris
2013-06-01
Stroke unit care offers significant benefits in survival and dependency when compared to general medical ward. Most stroke units are either acute or rehabilitation, but comprehensive (combined acute and rehabilitation) model (comprehensive stroke unit) is less common. To examine different levels of evidence of comprehensive stroke unit compared to other organized inpatient stroke care and share local experience of comprehensive stroke units. Cochrane Library and Medline (1980 to December 2010) review of English language articles comparing stroke units to alternative forms of stroke care delivery, different types of stroke unit models, and differences in processes of care within different stroke unit models. Different levels of comparative evidence of comprehensive stroke units to other models of stroke units are collected. There are no randomized controlled trials directly comparing comprehensive stroke units to other stroke unit models (either acute or rehabilitation). Comprehensive stroke units are associated with reduced length of stay and greatest reduction in combined death and dependency in a meta-analysis study when compared to other stroke unit models. Comprehensive stroke units also have better length of stay and functional outcome when compared to acute or rehabilitation stroke unit models in a cross-sectional study, and better length of stay in a 'before-and-after' comparative study. Components of stroke unit care that improve outcome are multifactorial and most probably include early mobilization. A comprehensive stroke unit model has been successfully implemented in metropolitan and rural hospital settings. Comprehensive stroke units are associated with reductions in length of stay and combined death and dependency and improved functional outcomes compared to other stroke unit models. A comprehensive stroke unit model is worth considering as the preferred model of stroke unit care in the planning and delivery of metropolitan and rural stroke services. © 2012 The Authors. International Journal of Stroke © 2012 World Stroke Organization.
Numakura, Mario; Kusakabe, Noriko; Ishige, Kazuya; Ohtake-Niimi, Shiori; Habuchi, Hiroko; Habuchi, Osami
2010-07-01
Chondroitin sulfate (CS) containing GlcA-GalNAc(4,6-SO(4)) (E unit) and CS containing GlcA(2SO(4))-GalNAc(6SO(4)) (D unit) have been implicated in various physiological functions. However, it has been poorly understood how the structure and contents of disulfated disaccharide units in CS contribute to these functions. We prepared CS libraries containing E unit or D unit in various proportions by in vitro enzymatic reactions using recombinant GalNAc 4-sulfate 6-O-sulfotransferase and uronosyl 2-O-sulfotransferase, and examined their inhibitory activity toward thrombin. The in vitro sulfated CSs containing disulfated disaccharide units showed concentration-dependent direct inhibition of thrombin when the proportion of E unit or D unit in the CSs was above 15-17%. The CSs containing both E unit and D unit exhibited higher inhibitory activity toward thrombin than the CSs containing either E unit or D unit alone, if the proportion of the total disulfated disaccharide units of these CSs was comparable. The thrombin-catalyzed degradation of fibrinogen, a physiological substrate for thrombin, was also inhibited by the CS containing both E unit and D unit. These observations indicate that the enzymatically prepared CS libraries containing various amounts of disulfated disaccharide units appear to be useful for elucidating the physiological function of disulfated disaccharide units in CS.
24 CFR Appendix B to Part 1000 - IHBG Block Grant Formula Mechanisms
Code of Federal Regulations, 2012 CFR
2012-04-01
... unit subsidy for Low-Rent units ($2,440*INF). MH+TK = number of Mutual Help and Turnkey III units. HOSUB = national per unit subsidy for Homeownership units ($528*INF). S8 = number of Section 8 units. S8SUB = national per unit subsidy for Section 8 units = ($3,625*INF). AELFMR = greater of AEL Factor or...
24 CFR Appendix B to Part 1000 - IHBG Block Grant Formula Mechanisms
Code of Federal Regulations, 2014 CFR
2014-04-01
... unit subsidy for Low-Rent units ($2,440*INF). MH+TK = number of Mutual Help and Turnkey III units. HOSUB = national per unit subsidy for Homeownership units ($528*INF). S8 = number of Section 8 units. S8SUB = national per unit subsidy for Section 8 units = ($3,625*INF). AELFMR = greater of AEL Factor or...
24 CFR Appendix B to Part 1000 - IHBG Block Grant Formula Mechanisms
Code of Federal Regulations, 2013 CFR
2013-04-01
... unit subsidy for Low-Rent units ($2,440*INF). MH+TK = number of Mutual Help and Turnkey III units. HOSUB = national per unit subsidy for Homeownership units ($528*INF). S8 = number of Section 8 units. S8SUB = national per unit subsidy for Section 8 units = ($3,625*INF). AELFMR = greater of AEL Factor or...
36 CFR 242.24 - Customary and traditional use determinations.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Islands Moose Residents of Units 1B, 2, and 3. Unit 4 Brown Bear Residents of Unit 4 and Kake. Unit 4 Deer... Federal subsistence priority. Unit 6A Wolf Residents of Units 5A, 6, 9, 10 (Unimak Island only), 11-13, Chickaloon, and 16-26. Unit 6, remainder Wolf Residents of Units 6, 9, 10 (Unimak Island only), 11-13...
36 CFR 242.24 - Customary and traditional use determinations.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Islands Moose Residents of Units 1B, 2, and 3. Unit 4 Brown Bear Residents of Unit 4 and Kake. Unit 4 Deer... Federal subsistence priority. Unit 6A Wolf Residents of Units 5A, 6, 9, 10 (Unimak Island only), 11-13, Chickaloon, and 16-26. Unit 6, remainder Wolf Residents of Units 6, 9, 10 (Unimak Island only), 11-13...
36 CFR 242.24 - Customary and traditional use determinations.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Islands Moose Residents of Units 1B, 2, and 3. Unit 4 Brown Bear Residents of Unit 4 and Kake. Unit 4 Deer... Federal subsistence priority. Unit 6A Wolf Residents of Units 5A, 6, 9, 10 (Unimak Island only), 11-13, Chickaloon, and 16-26. Unit 6, remainder Wolf Residents of Units 6, 9, 10 (Unimak Island only), 11-13...
Selenium, fluorine, and arsenic in surficial materials of the conterminous United States
Shacklette, Hansford T.; Boerngen, Josephine G.; Keith, John R.
1974-01-01
Concentrations of selenium, fluorine, and arsenic in 912, 911, and 910 samples, respectively, of soils and other regoliths from sites approximately 50 miles (80 km) apart throughout the United States are represented on maps by symbols showing five ranges of values. Histograms of the concentrations of these elements are also given. The geometric-mean concentrations (ppm) in the samples, grouped by area, are as follows: Selenium-- Entire United States, 0.31; Western United States, 0.25; and Eastern United States, 0.39. Fluorine-- Entire United States, 180; Western United States, 250; and Eastern United States, 115. Arsenic-- Entire United States, 5.8; Western United States, 6.1; and Eastern United States, 5.4.
Nurse work environment and quality of care by unit types: A cross-sectional study.
Ma, Chenjuan; Olds, Danielle M; Dunton, Nancy E
2015-10-01
Nursing unit is the micro-organization in the hospital health care system in which integrated patient care is provided. Nursing units of different types serve patients with distinct care goals, clinical tasks, and social structures and norms. However, empirical evidence is sparse on unit type differences in quality of care and its relation with nurse work environment. Nurse work environment has been found as an important nursing factor predicting nurse and patient outcomes. To examine the unit type differences in nurse-reported quality of care, and to identify the association between unit work environment and quality of care by unit types. This is a cross-sectional study using nurse survey data (2012) from US hospitals nationwide. The nurse survey collected data on quality of care, nurse work environment, and other work related information from staff nurses working in units of various types. Unit types were systematically classified across hospitals. The unit of analysis was the nursing unit, and the final sample included 7677 units of 14 unit types from 577 hospitals in 49 states in the US. Multilevel regressions were used to assess the relationship between nurse work environment and quality of care across and by unit types. On average, units had 58% of the nurses reporting excellent quality of care and 40% of the nurses reporting improved quality of care over the past year. Unit quality of care varied by unit types, from 43% of the nurses in adult medical units to 73% of the nurses in interventional units rating overall quality of care on unit as excellent, and from 35% of the nurses in adult critical care units to 44% of the nurses in adult medical units and medical-surgical combined units reporting improved quality of care. Estimates from regressions indicated that better unit work environments were associated with higher quality of care when controlling various hospital and unit covariates; and this association persisted among units of different types. Unit type differences exist in the overall quality of care as well as achievement in improving quality of care. The low rates of nurses reporting improvement in the quality of nursing care to patients suggest that further interventions focusing at the unit-level are needed for achieving high care quality. Findings from our study also suggest that improving nurse work environments can be an effective strategy to improve quality of care. Copyright © 2015 Elsevier Ltd. All rights reserved.
HydroUnits: A Python-based Physical Units Management Tool in Hydrologic Computing Systems
NASA Astrophysics Data System (ADS)
Celicourt, P.; Piasecki, M.
2015-12-01
While one objective of data management systems is to provide the units when annotating the collected data, another is that the units must be correctly manipulated during conversion steps. This is not a trivial task however and the units conversion time and errors for large datasets can be quite expensive. To date, more than a dozen Python modules have been developed to deal with units attached to quantities. However, they fall short in many ways and also suffer from not integrating with a units controlled vocabulary. Moreover, none of them permits the encoding of some complex units defined in the Consortium of Universities for the Advancement of Hydrologic Sciences, Inc.'s Observations Data Model (CUAHSI ODM) as a vectorial representation for storage demand reduction and does not incorporate provision to accommodate unforeseen standards-based units. We developed HydroUnits, a Python-based units management tool for three specific purposes: encoding of physical units in the Transducer Electronic Data Sheet (TEDS) as defined in the IEEE 1451.0 standard, performing dimensional analysis and on-the-fly conversion of time series allowing users to retrieve data from a data source in a desired equivalent unit while accommodating unforeseen and user-defined units. HydroUnits differentiates itself to existing tools by a number of factors including the implementation approach adopted, the adoption of standard-based units naming conventions and more importantly the emphasis on units controlled vocabularies which are a critical aspect of units treatment. Additionally, HydroUnits supports unit conversion for quantities with additive scaling factor, and natively supports time series conversion and takes leap years into consideration for units consisting of the time dimension (e.g., month, minute). Due to its overall implementation approach, HydroUnits exhibits a high level of versatility that no other tool we are aware of has achieved.
7 CFR 1160.104 - United States.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 9 2012-01-01 2012-01-01 false United States. 1160.104 Section 1160.104 Agriculture... Definitions § 1160.104 United States. United States means the 48 contiguous states in the continental United States and the District of Columbia, except that United States means the 50 states of the United States...
7 CFR 1160.104 - United States.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 9 2011-01-01 2011-01-01 false United States. 1160.104 Section 1160.104 Agriculture... Definitions § 1160.104 United States. United States means the 48 contiguous states in the continental United States and the District of Columbia, except that United States means the 50 states of the United States...
7 CFR 1160.104 - United States.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 9 2014-01-01 2013-01-01 true United States. 1160.104 Section 1160.104 Agriculture... Definitions § 1160.104 United States. United States means the 48 contiguous states in the continental United States and the District of Columbia, except that United States means the 50 states of the United States...
7 CFR 1160.104 - United States.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 9 2013-01-01 2013-01-01 false United States. 1160.104 Section 1160.104 Agriculture... Definitions § 1160.104 United States. United States means the 48 contiguous states in the continental United States and the District of Columbia, except that United States means the 50 states of the United States...
2002-03-01
sections consists of four units, the Domestic Terrorism Operations Unit, the WMD Operations Unit, the WMD Countermeasures Unit, and Special Events Management Unit...Countermeasures Unit Chief Special Events Management Unit Chief Domestic Terrorism/ Counterterrorism Section Chief International Terrorism Section Asstistant
7 CFR 1160.104 - United States.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 9 2010-01-01 2009-01-01 true United States. 1160.104 Section 1160.104 Agriculture... Definitions § 1160.104 United States. United States means the 48 contiguous states in the continental United States and the District of Columbia, except that United States means the 50 states of the United States...
Lehmann, H P
1979-01-01
The development of the International System of Units (Systeme International d'Unites--SE Units), based on seven fundamental quantities--length, mass, time, electric current, thermodynamic temperature, luminous intensity, and amount of substance is described. Units (coherent and noncoherent) for other measurable quantities that are derived from the seven basic quantities are reviewed. The rationale for the use of SE units in medicine, primarily as applied to clinical laboratory data, is discussed, and arguments are presented for the rigid adoption of SI units in medicine and for exceptions. Tables are given for the basic and derived SI units used in medicine and for conversion factors from the quantities and units in current use to those in SI units.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Safety precautions for remote afterloader units, teletherapy units, and gamma stereotactic radiosurgery units. 35.615 Section 35.615 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Safety precautions for remote afterloader units, teletherapy units, and gamma stereotactic radiosurgery units. 35.615 Section 35.615 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Safety precautions for remote afterloader units, teletherapy units, and gamma stereotactic radiosurgery units. 35.615 Section 35.615 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Safety precautions for remote afterloader units, teletherapy units, and gamma stereotactic radiosurgery units. 35.615 Section 35.615 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and...
Hospital Magnet Status, Unit Work Environment, and Pressure Ulcers.
Ma, Chenjuan; Park, Shin Hye
2015-11-01
To identify how organizational nursing factors at different structural levels (i.e., unit-level work environment and hospital Magnet status) are associated with hospital-acquired pressure ulcers (HAPUs) in U.S. acute care hospitals. A cross-sectional observational study used data from the National Database of Nursing Quality Indicators®. Responses from 33,845 registered nurses (RNs) were used to measure unit work environments. The unit of analysis was the nursing unit, and there were 1,381 units in 373 hospitals in the United States. Unit work environment was measured by the Practice Environment Scale of Nurse Working Index (PES-NWI). Multilevel logistic regressions were used to estimate the effects of unit work environment and hospital Magnet status on HAPUs. All models were controlled for hospital and unit characteristics when considering clustering of units within hospitals. Magnet hospital units had 21% lower odds of having an HAPU than non-Magnet hospital units (95% confidence interval [CI], 0.64-0.98). With one unit increase of the PES-NWI score, units had 29% lower odds of having an HAPU (95% CI, 0.55-0.91). When including both hospital Magnet status and unit work environment in the model, hospital Magnet status no longer had a significant effect on HAPUs (odds ratio [OR] = 0.82; 95% CI, 0.66-1.02), whereas the significant effect of unit work environment persisted (OR = 0.73; 95% CI, 0.56-0.93). Both hospital and unit environments were significantly associated with HAPUs, and the unit-level work environment can be more influential in reducing HAPUs. Investment in the nurse work environments at both the hospital level and unit level has the potential to reduce HAPUs; and additional to hospital-level initiatives (e.g., Magnet recognition program), efforts targeting on-unit work environments deserve more attention. © 2015 Sigma Theta Tau International.
SI Units to be Used in Place of Imperial Units and Old Metric Units
ERIC Educational Resources Information Center
Australian Science Teachers Journal, 1975
1975-01-01
A table lists the following quantities in imperial units, old metric units, and SI units: mass, force, energy, torque, power, pressure, temperature, thermal conductivity, frequency, dynamic viscosity, and kinematic viscosity. (MLH)
NASA Astrophysics Data System (ADS)
Di Giorgio, Anna Maria; Biondi, David; Saggin, Bortolino; Shatalina, Irina; Viterbini, Maurizio; Giusi, Giovanni; Liu, Scige J.; Cerulli-Irelli, Paquale; Van Loon, Dennis; Cara, Christophe
2012-09-01
We present the preliminary design of the Instrument Control Unit (ICU) of the SpicA FAR infrared Instrument (SAFARI), an imaging Fourier Transform Spectrometer (FTS) designed to give continuous wavelength coverage in both photometric and spectroscopic modes from around 34 to 210 µm. Due to the stringent requirements in terms of mass and volume, the overall SAFARI warm electronics will be composed by only two main units: Detector Control Unit and ICU. ICU is therefore a macro-unit incorporating the four digital sub-units dedicated to the control of the overall instrument functionalities: the Cooler Control Unit, the Mechanism Control Unit, the Digital processing Unit and the Power Supply Unit. Both the mechanical solution adopted to host the four sub-units and the internal electrical architecture are presented as well as the adopted redundancy approach.
Maritime Domain Awareness: C4I for the 1000 Ship Navy
2009-12-04
unit action, provide unit sensed contacts, coordinate unit operations, process unit information, release image , and release contact report, Figure 33...Intelligence Tasking Request Intelligence Summary Release Unit Person Incident Release Unit Vessel Incident Process Intelligence Tasking Release Image ...xi LIST OF FIGURES Figure 1. Functional Problem Sequence Process Flow. ....................................................4 Figure 2. United
Does size matter? Animal units and animal unit months
Lamar Smith; Joe Hicks; Scott Lusk; Mike Hemmovich; Shane Green; Sarah McCord; Mike Pellant; John Mitchell; Judith Dyess; Jim Sprinkle; Amanda Gearhart; Sherm Karl; Mike Hannemann; Ken Spaeth; Jason Karl; Matt Reeves; Dave Pyke; Jordan Spaak; Andrew Brischke; Del Despain; Matt Phillippi; Dave Weixelmann; Alan Bass; Jessie Page; Lori Metz; David Toledo; Emily Kachergis
2017-01-01
The concepts of animal units, animal unit months, and animal unit equivalents have long been used as standards for range management planning, estimating stocking rates, reporting actual use, assessing grazing fees, ranch appraisal, and other purposes. Increasing size of cattle on rangelands has led some to suggest that the definition of animal units and animal unit...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-15
... DEPARTMENT OF JUSTICE Antitrust Division United States et al. v. United Regional Health Care... proposed Final Judgment in United States and State of Texas v. United Regional Health Care System, Civil... Texas, (RCO) Plaintiffs, V. United Regional Health Care System, Defendant. Case No.: 7:11-cv-00030...
Characteristics of unit-level patient safety culture in hospitals in Japan: a cross-sectional study.
Fujita, Shigeru; Seto, Kanako; Kitazawa, Takefumi; Matsumoto, Kunichika; Hasegawa, Tomonori
2014-10-22
Patient safety culture (PSC) has an important role in determining safety and quality in healthcare. Currently, little is known about the status of unit-level PSC in hospitals in Japan. To develop appropriate strategies, characteristics of unit-level PSC should be investigated. Work units may be classified according to the characteristics of PSC, and common problems and appropriate strategies may be identified for each work unit category. This study aimed to clarify the characteristics of unit-level PSC in hospitals in Japan. In 2012, a cross-sectional study was conducted at 18 hospitals in Japan. The Hospital Survey on Patient Safety Culture questionnaire, developed by the United States Agency for Healthcare Research and Quality, was distributed to all healthcare workers (n =12,076). Percent positive scores for 12 PSC sub-dimensions were calculated for each unit, and cluster analysis was used to categorise the units according to the percent positive scores. A generalised linear mixed model (GLMM) was used to analyse the results of the cluster analysis, and odds ratios (ORs) for categorisation as high-PSC units were calculated for each unit type. A total of 9,124 respondents (75.6%) completed the questionnaire, and valid data from 8,700 respondents (72.0%) were analysed. There were 440 units in the 18 hospitals. According to the percent positive scores for the 12 sub-dimensions, the 440 units were classified into 2 clusters: high-PSC units (n =184) and low-PSC units (n =256). Percent positive scores for all PSC sub-dimensions for high-PSC units were significantly higher than those for low-PSC units. The GLMM revealed that the combined unit type of 'Obstetrics and gynaecology ward, perinatal ward or neonatal intensive care unit' was significantly more likely to be categorised as high-PSC units (OR =9.7), and 'Long-term care ward' (OR =0.2), 'Rehabilitation unit' (OR =0.2) and 'Administration unit' (OR =0.3) were significantly less likely to be categorised as high-PSC units. Our study findings demonstrate that PSC varies considerably among different unit types in hospitals in Japan. Factors contributing to low PSC should be identified and possible measures for improving PSC should be developed and initiated.
Code of Federal Regulations, 2010 CFR
2010-01-01
... COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and..., teletherapy unit, or gamma stereotactic radiosurgery unit. A licensee shall use sealed sources in photon...
Code of Federal Regulations, 2011 CFR
2011-01-01
... COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and..., teletherapy unit, or gamma stereotactic radiosurgery unit. A licensee shall use sealed sources in photon...
Code of Federal Regulations, 2014 CFR
2014-01-01
... COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and..., teletherapy unit, or gamma stereotactic radiosurgery unit. A licensee shall use sealed sources in photon...
Code of Federal Regulations, 2013 CFR
2013-01-01
... COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and..., teletherapy unit, or gamma stereotactic radiosurgery unit. A licensee shall use sealed sources in photon...
Code of Federal Regulations, 2012 CFR
2012-01-01
... COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units, Teletherapy Units, and..., teletherapy unit, or gamma stereotactic radiosurgery unit. A licensee shall use sealed sources in photon...
Code of Federal Regulations, 2012 CFR
2012-07-01
... of disputes between the United States or United States nationals and the Government of Iran. 560.510... between the United States or United States nationals and the Government of Iran. (a) Except as otherwise... with awards, decisions or orders of the Iran-United States Claims Tribunal in The Hague, the...
Code of Federal Regulations, 2010 CFR
2010-07-01
... resolution of disputes between the United States or United States nationals and the Government of Iran. 560... between the United States or United States nationals and the Government of Iran. (a) Except as otherwise... with awards, decisions or orders of the Iran-United States Claims Tribunal in The Hague, the...
50 CFR 100.24 - Customary and traditional use determinations.
Code of Federal Regulations, 2013 CFR
2013-10-01
.... Baker, and Meyers Chuck. Unit 3, Wrangell and Mitkof Islands Moose Residents of Units 1B, 2, and 3. Unit... Units 5A, 6, 9, 10 (Unimak Island only), 11-13, Chickaloon, and 16-26. Unit 6, remainder Wolf Residents of Units 6, 9, 10 (Unimak Island only), 11-13, Chickaloon, and 16-26. Unit 7 Brown Bear No Federal...
50 CFR 100.24 - Customary and traditional use determinations.
Code of Federal Regulations, 2012 CFR
2012-10-01
.... Baker, and Meyers Chuck. Unit 3, Wrangell and Mitkof Islands Moose Residents of Units 1B, 2, and 3. Unit... Units 5A, 6, 9, 10 (Unimak Island only), 11-13, Chickaloon, and 16-26. Unit 6, remainder Wolf Residents of Units 6, 9, 10 (Unimak Island only), 11-13, Chickaloon, and 16-26. Unit 7 Brown Bear No Federal...
50 CFR 100.24 - Customary and traditional use determinations.
Code of Federal Regulations, 2014 CFR
2014-10-01
.... Baker, and Meyers Chuck. Unit 3, Wrangell and Mitkof Islands Moose Residents of Units 1B, 2, and 3. Unit... Units 5A, 6, 9, 10 (Unimak Island only), 11-13, Chickaloon, and 16-26. Unit 6, remainder Wolf Residents of Units 6, 9, 10 (Unimak Island only), 11-13, Chickaloon, and 16-26. Unit 7 Brown Bear No Federal...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-18
... New Nuclear Power Plant Units on Operating Units at Multi-Unit Sites AGENCY: Nuclear Regulatory... construct and operate new nuclear power plants (NPPs) on multi-unit sites to provide an evaluation of the... License) of New Nuclear Power Plants on Operating Units at Multi-Unit Sites (Package). ML112630039 Federal...
Programmable partitioning for high-performance coherence domains in a multiprocessor system
Blumrich, Matthias A [Ridgefield, CT; Salapura, Valentina [Chappaqua, NY
2011-01-25
A multiprocessor computing system and a method of logically partitioning a multiprocessor computing system are disclosed. The multiprocessor computing system comprises a multitude of processing units, and a multitude of snoop units. Each of the processing units includes a local cache, and the snoop units are provided for supporting cache coherency in the multiprocessor system. Each of the snoop units is connected to a respective one of the processing units and to all of the other snoop units. The multiprocessor computing system further includes a partitioning system for using the snoop units to partition the multitude of processing units into a plurality of independent, memory-consistent, adjustable-size processing groups. Preferably, when the processor units are partitioned into these processing groups, the partitioning system also configures the snoop units to maintain cache coherency within each of said groups.
31 CFR 596.313 - United States person.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 31 Money and Finance:Treasury 3 2013-07-01 2013-07-01 false United States person. 596.313 Section... General Definitions § 596.313 United States person. The term United States person means any United States... States, or any person in the United States. ...
31 CFR 596.313 - United States person.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 31 Money and Finance:Treasury 3 2012-07-01 2012-07-01 false United States person. 596.313 Section... General Definitions § 596.313 United States person. The term United States person means any United States... States, or any person in the United States. ...
31 CFR 596.313 - United States person.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 31 Money and Finance:Treasury 3 2014-07-01 2014-07-01 false United States person. 596.313 Section... General Definitions § 596.313 United States person. The term United States person means any United States... States, or any person in the United States. ...
Publications - GMC 234 | Alaska Division of Geological & Geophysical
following North Slope wells: Itkillik River Unit #1, Nora Fed #1, Toolik Fed #1, Kemik Unit #1, Lupine Unit following North Slope wells: Itkillik River Unit #1, Nora Fed #1, Toolik Fed #1, Kemik Unit #1, Lupine Unit
Properties of single motor units in medial gastrocnemius muscles of adult and old rats.
Kadhiresan, V A; Hassett, C A; Faulkner, J A
1996-01-01
1. The purpose of this study was to determine the role of motor unit remodelling in the deficit that develops in the maximum isometric tetanic force (Fo) of whole medial gastrocnemius (MGN) muscles in old compared with adult rats. The Fo values and morphological data were determined for MGN muscles and eighty-two single motor units in muscles of adult (10-12 months) and sixty-two units in those of old (24-26 months) F344 rats. During an unfused tetanus, fast and slow (S) motor units were identified by the presence and absence of sag, respectively. Fast-fatigable (FF) and fast-fatigue-resistant (FR) units were classified by fatigue indices less than or greater than 0.50, respectively. 2. For old rats, whole MGN muscle Fo was 29% less than the value of 11.2 N measured for adult rats. The deficit in whole muscle Fo of old rats resulted from equivalent decreases in the number of motor units, 16% smaller than the adult value of ninety-seven, and in the mean motor unit Fo value, 14% less than the adult value of 117 mN. 3. With ageing, little motor unit remodelling occurred in FR units, whereas the S and FF motor units demonstrated dramatic, but opposing, changes. For S units, the number of units remained constant, but the number of fibres per motor unit increased 3-fold from 57 to 165. In contrast, the number of FF units decreased by 34% and the number of fibres per motor unit of the remaining units decreased to 86% of the adult value of 333. The age-related remodelling of motor units appeared to involve denervation of fast muscle fibres with reinnervation of denervated fibres by axonal sprouting from slow fibres. PMID:8782115
Analysis of potential benefits of integrated-gasifier combined cycles for a utility system
NASA Technical Reports Server (NTRS)
Choo, Y. K.
1983-01-01
Potential benefits of integrated gasifier combined cycle (IGCC) units were evaluated for a reference utility system by comparing long range expansion plans using IGCC units and gas turbine peakers with a plan using only state of the art steam turbine units and gas turbine peakers. Also evaluated was the importance of the benefits of individual IGCC unit characteristics, particularly unit efficiency, unit equivalent forced outage rate, and unit size. A range of IGCC units was analyzed, including cases achievable with state of the art gas turbines and cases assuming advanced gas turbine technology. All utility system expansion plans that used IGCC units showed substantial savings compared with the base expansion plan using the steam turbine units.
75 FR 5373 - United States Mint
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-02
... DEPARTMENT OF THE TREASURY United States Mint ACTION: Notification of Pricing for 2010 United States Mint Presidential $1 Coin Proof Set. \\TM\\ SUMMARY: The United States Mint is announcing the price of the 2010 United States Mint Presidential $1 Coin Proof Set. The 2010 United States Mint...
Service equipment for use in hostile environments
NASA Technical Reports Server (NTRS)
Dolce, James L. (Inventor); Gordon, Andrew L. (Inventor)
1994-01-01
Service equipment for use in hostile environments includes a detachable service unit secured to a stationary service unit. The detachable service unit includes a housing with an exterior plate, a power control interface for connection to an exterior power source, locating pins located in said exterior plate, an electrical connector in the exterior plate electrically coupled to said power control interface, and a pair of clamping receptacles formed in the exterior plate and located on adjacent opposite edges of the exterior plate. The stationary unit includes an electrical connector for connection to the electrical connector of the detachable service unit, a clamping apparatus for clamping and unclamping the detachable service unit from the stationary unit, a base clamp assembly for mounting the clamping apparatus onto the stationary unit, and locating pin holes for receiving the locating pins and aligning the detachable service unit onto the stationary unit. The detachable service unit and stationary unit have mating scalloped faces which aid in alignment and provide a mechanism for heat dissipation.
Three conceptual units for behavior
Moxley, Roy
1987-01-01
Three generic units for behavior are examined in terms of their background: an if-then unit for stimulus and response (S-R), a holistic unit for Kantor's behavior segment, and an AB-because-of-C unit for Skinner's three-term contingency. The units are distinguished in terms of their respective historical backgrounds, causal modes, advantages, and disadvantages. The ways in which these units may be compatible are discussed. PMID:22477957
ERIC Educational Resources Information Center
Minnesota Univ., Minneapolis. Project Social Studies Curriculum Center.
This is the fifth of seven resource units for a twelfth grade course on value conflicts and policy decisions. The topic for this unit is racial conflict in the United States. The introduction explains how this unit coincides with other units of the K-12 series which have treated intergroup relations. The objectives are listed as to…
31 CFR 560.319 - United States depository institution.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 31 Money and Finance:Treasury 3 2012-07-01 2012-07-01 false United States depository institution... General Definitions § 560.319 United States depository institution. The term United States depository... within the United States, or any agency, office or branch located in the United States of a foreign...
33 CFR 125.23 - United States citizens.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false United States citizens. 125.23... VESSELS § 125.23 United States citizens. Acceptable evidence of United States citizenship is described in... of birth. (e) United States passport. (f) A commission in one of the armed forces of the United...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 3 2011-01-01 2011-01-01 false United States. 60.127 Section 60.127 Agriculture... FOR FISH AND SHELLFISH General Provisions Definitions § 60.127 United States. United States means the... the United States, and the waters of the United States as defined in § 60.132. ...
5 CFR 8.2 - Appointment of United States citizens.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 5 Administrative Personnel 1 2013-01-01 2013-01-01 false Appointment of United States citizens. 8... APPOINTMENTS TO OVERSEAS POSITIONS (RULE VIII) § 8.2 Appointment of United States citizens. United States... appointments for United States citizens recruited within the continental limits of the United States whenever...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 3 2014-01-01 2014-01-01 false United States. 60.127 Section 60.127 Agriculture... FOR FISH AND SHELLFISH General Provisions Definitions § 60.127 United States. United States means the... the United States, and the waters of the United States as defined in § 60.132. ...
33 CFR 125.23 - United States citizens.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false United States citizens. 125.23... VESSELS § 125.23 United States citizens. Acceptable evidence of United States citizenship is described in... of birth. (e) United States passport. (f) A commission in one of the armed forces of the United...
31 CFR 560.319 - United States depository institution.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 31 Money and Finance:Treasury 3 2014-07-01 2014-07-01 false United States depository institution... REGULATIONS General Definitions § 560.319 United States depository institution. The term United States... United States or any jurisdiction within the United States, or any agency, office, or branch located in...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 3 2013-01-01 2013-01-01 false United States. 60.127 Section 60.127 Agriculture... FOR FISH AND SHELLFISH General Provisions Definitions § 60.127 United States. United States means the... the United States, and the waters of the United States as defined in § 60.132. ...
5 CFR 8.2 - Appointment of United States citizens.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Appointment of United States citizens. 8... APPOINTMENTS TO OVERSEAS POSITIONS (RULE VIII) § 8.2 Appointment of United States citizens. United States... appointments for United States citizens recruited within the continental limits of the United States whenever...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 3 2012-01-01 2012-01-01 false United States. 60.127 Section 60.127 Agriculture... FOR FISH AND SHELLFISH General Provisions Definitions § 60.127 United States. United States means the... the United States, and the waters of the United States as defined in § 60.132. ...
31 CFR 560.319 - United States depository institution.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 31 Money and Finance:Treasury 3 2013-07-01 2013-07-01 false United States depository institution... REGULATIONS General Definitions § 560.319 United States depository institution. The term United States... United States or any jurisdiction within the United States, or any agency, office, or branch located in...
5 CFR 8.2 - Appointment of United States citizens.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 5 Administrative Personnel 1 2014-01-01 2014-01-01 false Appointment of United States citizens. 8... APPOINTMENTS TO OVERSEAS POSITIONS (RULE VIII) § 8.2 Appointment of United States citizens. United States... appointments for United States citizens recruited within the continental limits of the United States whenever...
33 CFR 125.23 - United States citizens.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false United States citizens. 125.23... VESSELS § 125.23 United States citizens. Acceptable evidence of United States citizenship is described in... of birth. (e) United States passport. (f) A commission in one of the armed forces of the United...
5 CFR 8.2 - Appointment of United States citizens.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 5 Administrative Personnel 1 2012-01-01 2012-01-01 false Appointment of United States citizens. 8... APPOINTMENTS TO OVERSEAS POSITIONS (RULE VIII) § 8.2 Appointment of United States citizens. United States... appointments for United States citizens recruited within the continental limits of the United States whenever...
33 CFR 125.23 - United States citizens.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false United States citizens. 125.23... VESSELS § 125.23 United States citizens. Acceptable evidence of United States citizenship is described in... of birth. (e) United States passport. (f) A commission in one of the armed forces of the United...
33 CFR 125.23 - United States citizens.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false United States citizens. 125.23... VESSELS § 125.23 United States citizens. Acceptable evidence of United States citizenship is described in... of birth. (e) United States passport. (f) A commission in one of the armed forces of the United...
75 FR 13345 - Pricing for Certain 2010 United States Mint Products
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-19
... DEPARTMENT OF THE TREASURY United States Mint Pricing for Certain 2010 United States Mint Products AGENCY: United States Mint, Department of the Treasury. ACTION: Notice. SUMMARY: The United States Mint is announcing the price of the 2010 United States Mint Presidential $1 Coin and First Spouse Medal...
Simulation of motor unit recruitment and microvascular unit perfusion: spatial considerations.
Fuglevand, A J; Segal, S S
1997-10-01
Muscle fiber activity is the principal stimulus for increasing capillary perfusion during exercise. The control elements of perfusion, i.e., microvascular units (MVUs), supply clusters of muscle fibers, whereas the control elements of contraction, i.e., motor units, are composed of fibers widely scattered throughout muscle. The purpose of this study was to examine how the discordant spatial domains of MVUs and motor units could influence the proportion of open capillaries (designated as perfusion) throughout a muscle cross section. A computer model simulated the locations of perfused MVUs in response to the activation of up to 100 motor units in a muscle with 40,000 fibers and a cross-sectional area of 100 mm2. The simulation increased contraction intensity by progressive recruitment of motor units. For each step of motor unit recruitment, the percentage of active fibers and the number of perfused MVUs were determined for several conditions: 1) motor unit fibers widely dispersed and motor unit territories randomly located (which approximates healthy human muscle), 2) regionalized motor unit territories, 3) reversed recruitment order of motor units, 4) densely clustered motor unit fibers, and 5) increased size but decreased number of motor units. The simulations indicated that the widespread dispersion of motor unit fibers facilitates complete capillary (MVU) perfusion of muscle at low levels of activity. The efficacy by which muscle fiber activity induced perfusion was reduced 7- to 14-fold under conditions that decreased the dispersion of active fibers, increased the size of motor units, or reversed the sequence of motor unit recruitment. Such conditions are similar to those that arise in neuromuscular disorders, with aging, or during electrical stimulation of muscle, respectively.
Tiboni, S; Bhangu, A; Hall, N J
2014-05-01
Appendicectomy for acute appendicitis in children may be performed in specialist centres by paediatric surgeons or in general surgery units. Service provision and outcome of appendicectomy in children may differ between such units. This multicentre observational study included all children (aged less than 16 years) who had an appendicectomy at either a paediatric surgery unit or general surgery unit. The primary outcome was normal appendicectomy rate (NAR). Secondary outcomes included 30-day adverse events, use of ultrasound imaging and laparoscopy, and consultant involvement in procedures. Appendicectomies performed in 19 paediatric surgery units (242 children) and 54 general surgery units (461 children) were included. Children treated in paediatric surgery units were younger and more likely to have a preoperative ultrasound examination, a laparoscopic procedure, a consultant present at the procedure, and histologically advanced appendicitis than children treated in general surgery units. The unadjusted NAR was significantly lower in paediatric surgery units (odds ratio (OR) 0.37, 95 per cent confidence interval 0.23 to 0.59; P < 0.001), and the difference persisted after adjusting for age, sex and use of preoperative ultrasound imaging (OR 0.34, 0.21 to 0.57; P < 0.001). Female sex and preoperative ultrasonography, but not age, were significantly associated with normal appendicectomy in general surgery units but not in paediatric surgery units in this adjusted model. The unadjusted 30-day adverse event rate was higher in paediatric surgery units than in general surgery units (OR 1.90, 1.18 to 3.06; P = 0.011). When adjusted for case mix and consultant presence at surgery, no statistically significant relationship between centre type and 30-day adverse event rate existed (OR 1.59, 0.93 to 2.73; P = 0.091). The NAR in general surgery units was over twice that in paediatric surgery units. Despite a more severe case mix, paediatric surgery units had a similar 30-day adverse event rate to general surgery units. Service provision differs between paediatric and general surgery units. © 2014 BJS Society Ltd. Published by John Wiley & Sons Ltd.
Integrated and Applied Curriculum: Six School-to-Work Units.
ERIC Educational Resources Information Center
Lo Guidice, Tom, Comp.
This publication consists of six units for middle and high school grades that incorporate school-to-work (STW). The six units were developed by six practicing teachers. The first unit, "Wellness: An Integrated Unit with STW Emphasis for Seventh Grade" (Sara Hellenbrand), provides STW objectives and a list of activities. The second unit,…
31 CFR 800.225 - United States.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 31 Money and Finance:Treasury 3 2012-07-01 2012-07-01 false United States. 800.225 Section 800.225... FOREIGN PERSONS Definitions § 800.225 United States. The term United States or U.S. means the United States of America, the States of the United States, the District of Columbia, and any commonwealth...
31 CFR 800.225 - United States.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 31 Money and Finance:Treasury 3 2011-07-01 2011-07-01 false United States. 800.225 Section 800.225... FOREIGN PERSONS Definitions § 800.225 United States. The term United States or U.S. means the United States of America, the States of the United States, the District of Columbia, and any commonwealth...
31 CFR 800.225 - United States.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 31 Money and Finance:Treasury 3 2013-07-01 2013-07-01 false United States. 800.225 Section 800.225... FOREIGN PERSONS Definitions § 800.225 United States. The term United States or U.S. means the United States of America, the States of the United States, the District of Columbia, and any commonwealth...
31 CFR 800.225 - United States.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 31 Money and Finance:Treasury 3 2014-07-01 2014-07-01 false United States. 800.225 Section 800.225... FOREIGN PERSONS Definitions § 800.225 United States. The term United States or U.S. means the United States of America, the States of the United States, the District of Columbia, and any commonwealth...
Basic Facts about the United Nations.
ERIC Educational Resources Information Center
United Nations, New York, NY. Office of Public Information.
The work of the United Nations is described in summary form. Material is divided into sections on the origin, programs, purpose, principles, and structure of the United Nations; the United Nations at work for International Peace; the United Nations at Work for Economic and Social Development; The United Nations at Work for Decolonization; the…
Code of Federal Regulations, 2010 CFR
2010-01-01
..., International Boundary and Water Commission, United States and Mexico To Act as the Commissioner of the United... States and Mexico To Act as the Commissioner of the United States Section Memorandum for the Commissioner of the United States Section, International Boundary and Water Commission, United States and Mexico...
Distribution Grid Integration Unit Cost Database | Solar Research | NREL
Unit Cost Database Distribution Grid Integration Unit Cost Database NREL's Distribution Grid Integration Unit Cost Database contains unit cost information for different components that may be used to associated with PV. It includes information from the California utility unit cost guides on traditional
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Safety procedures and instructions for remote afterloader units, teletherapy units, and gamma stereotactic radiosurgery units. 35.610 Section 35.610 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units...
Code of Federal Regulations, 2010 CFR
2010-01-01
... Participation Act to Support the United Nations/African Union Mission in Darfur Presidential Documents Other... the United Nations Participation Act to Support the United Nations/African Union Mission in Darfur... the United Nations/African Union Mission in Darfur to support the airlift of equipment for...
24 CFR 983.259 - Overcrowded, under-occupied, and accessible units.
Code of Federal Regulations, 2010 CFR
2010-04-01
...-occupied, and accessible units. (a) Family occupancy of wrong-size or accessible unit. The PHA subsidy standards determine the appropriate unit size for the family size and composition. If the PHA determines that a family is occupying a: (1) Wrong-size unit, or (2) Unit with accessibility features that the...
40 CFR 60.2015 - What is a new incineration unit?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false What is a new incineration unit? 60... Industrial Solid Waste Incineration Units for Which Construction Is Commenced After November 30, 1999 or for... is a new incineration unit? (a) A new incineration unit is an incineration unit that meets either of...
40 CFR 60.2886 - What is a new incineration unit?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false What is a new incineration unit? 60... Waste Incineration Units for Which Construction is Commenced After December 9, 2004, or for Which... incineration unit? (a) A new incineration unit is an incineration unit subject to this subpart that meets...
28 CFR 541.49 - Review of control unit placement.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... Once every 30 days, the control unit team, comprised of the control unit manager and other members... required to attend the team meeting in order to be eligible for the previous month's stay in the control unit to be credited towards the projected duration of confinement in that unit. The unit team shall...
28 CFR 541.50 - Release from a control unit.
Code of Federal Regulations, 2010 CFR
2010-07-01
... general population of the institution which has a control unit. [49 FR 32991, Aug. 17, 1984, as amended at... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Release from a control unit. 541.50... INMATE DISCIPLINE AND SPECIAL HOUSING UNITS Control Unit Programs § 541.50 Release from a control unit...
28 CFR 541.50 - Release from a control unit.
Code of Federal Regulations, 2013 CFR
2013-07-01
... general population of the institution which has a control unit. [49 FR 32991, Aug. 17, 1984, as amended at... 28 Judicial Administration 2 2013-07-01 2013-07-01 false Release from a control unit. 541.50... INMATE DISCIPLINE AND SPECIAL HOUSING UNITS Control Unit Programs § 541.50 Release from a control unit...
28 CFR 541.50 - Release from a control unit.
Code of Federal Regulations, 2012 CFR
2012-07-01
... general population of the institution which has a control unit. [49 FR 32991, Aug. 17, 1984, as amended at... 28 Judicial Administration 2 2012-07-01 2012-07-01 false Release from a control unit. 541.50... INMATE DISCIPLINE AND SPECIAL HOUSING UNITS Control Unit Programs § 541.50 Release from a control unit...
28 CFR 541.50 - Release from a control unit.
Code of Federal Regulations, 2011 CFR
2011-07-01
... general population of the institution which has a control unit. [49 FR 32991, Aug. 17, 1984, as amended at... 28 Judicial Administration 2 2011-07-01 2011-07-01 false Release from a control unit. 541.50... INMATE DISCIPLINE AND SPECIAL HOUSING UNITS Control Unit Programs § 541.50 Release from a control unit...
28 CFR 541.50 - Release from a control unit.
Code of Federal Regulations, 2014 CFR
2014-07-01
... general population of the institution which has a control unit. [49 FR 32991, Aug. 17, 1984, as amended at... 28 Judicial Administration 2 2014-07-01 2014-07-01 false Release from a control unit. 541.50... INMATE DISCIPLINE AND SPECIAL HOUSING UNITS Control Unit Programs § 541.50 Release from a control unit...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Safety procedures and instructions for remote afterloader units, teletherapy units, and gamma stereotactic radiosurgery units. 35.610 Section 35.610 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Safety procedures and instructions for remote afterloader units, teletherapy units, and gamma stereotactic radiosurgery units. 35.610 Section 35.610 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Safety procedures and instructions for remote afterloader units, teletherapy units, and gamma stereotactic radiosurgery units. 35.610 Section 35.610 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Safety procedures and instructions for remote afterloader units, teletherapy units, and gamma stereotactic radiosurgery units. 35.610 Section 35.610 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Photon Emitting Remote Afterloader Units...
46 CFR 122.740 - Periodic servicing of hydrostatic release units.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Periodic servicing of hydrostatic release units. 122.740... hydrostatic release units. (a) Each hydrostatic release unit, other than a disposable unit, must be serviced... hydrostatic release unit must be marked in clearly legible letters with an expiration date of two years after...
75 FR 10561 - Pricing for 2010 United States Mint America the Beautiful QuartersTM
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-08
... DEPARTMENT OF THE TREASURY United States Mint Pricing for 2010 United States Mint America the...: Notice. SUMMARY: The United States Mint is announcing the price of the 2010 United States Mint America the Beautiful Quarters Two-Roll Set and the 2010 United States Mint America the Beautiful Quarters 100...
Examining Pharmacy Workforce Issues in the United States and the United Kingdom
Covvey, Jordan R.; Cohron, Peter P.
2015-01-01
Objective. To examine available data and actions surrounding current pharmacy workforce issues in the United States and United Kingdom. Methods. Published pharmacy workforce data from the United States and United Kingdom were gathered from various sources, including PUBMED, Internet search engines, and pharmacy organization websites. Data was collated from additional sources including scientific literature, internal documents, news releases, and policy positions. Results. The number of colleges and schools of pharmacy has expanded by approximately 50% in both the United States and United Kingdom over the previous decade. In the United States, continued demand for the pharmacy workforce has been forecasted, but this need is based on outdated supply figures and assumptions for economic recovery. In the United Kingdom, workforce modeling has predicted a significant future oversupply of pharmacists, and action within the profession has attempted to address the situation through educational planning and regulation. Conclusion. Workforce planning is an essential task for sustaining a healthy profession. Recent workforce planning mechanisms in the United Kingdom may provide guidance for renewed efforts within the profession in the United States. PMID:25861098
Rapanos v. United States & Carabell v. United States
Documents associated with guidance for implementing the definition of waters of the United States under the Clean Water Act following the Rapanos v. United States, and Carabell v. United States Supreme Court decision.
Engine speed control apparatus
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ishii, M.; Miyazaki, M.; Nakamura, N.
1986-11-04
This patent describes an engine speed control apparatus. The system comprises an actuator for adjusting an engine speed, a first unit for computing a desired engine speed, a second unit for detecting the actual engine speed, and a third unit for detecting the difference between the outputs of the first and second units. The system also includes a fourth unit for computing a control pulse width for the actuator in accordance with the output of the third unit, a fifth unit for generating a control signal, a sixth unit for driving the actuator in response to the output of themore » fifth unit, and a seventh unit for computing an optimal halt time to interrupt the driving of the actuator. The actuator is driven intermittently in conformity in the control pulse width and the halt time.« less
Distributed and recoverable digital control system
NASA Technical Reports Server (NTRS)
Stange, Kent (Inventor); Hess, Richard (Inventor); Kelley, Gerald B (Inventor); Rogers, Randy (Inventor)
2010-01-01
A real-time multi-tasking digital control system with rapid recovery capability is disclosed. The control system includes a plurality of computing units comprising a plurality of redundant processing units, with each of the processing units configured to generate one or more redundant control commands. One or more internal monitors are employed for detecting data errors in the control commands. One or more recovery triggers are provided for initiating rapid recovery of a processing unit if data errors are detected. The control system also includes a plurality of actuator control units each in operative communication with the computing units. The actuator control units are configured to initiate a rapid recovery if data errors are detected in one or more of the processing units. A plurality of smart actuators communicates with the actuator control units, and a plurality of redundant sensors communicates with the computing units.
Stritesky, Gretta; Wadsworth, Kimberly; Duffy, Merry; Buck, Kelly; Dehn, Jason
2018-02-01
Umbilical cord blood units provide an important stem cell source for transplantation, particularly for patients of ethnic diversity who may not have suitably matched available, adult-unrelated donors. However, with the cost of cord blood unit acquisition from public banks significantly higher than that for adult-unrelated donors, attention is focused on decreasing cost yet still providing cord blood units to patients in need. Historical practices of banking units with low total nucleated cell counts, including units with approximately 90 × 10 7 total nucleated cells, indicates that most banked cord blood units have much lower total nucleated cell counts than are required for transplant. The objective of this study was to determine the impact on the ability to identify suitable cord blood units for transplantation if the minimum total nucleated cell count for banking were increased from 90 × 10 7 to 124 or 149 × 10 7 . We analyzed ethnically diverse patients (median age, 3 years) who underwent transplantation of a single cord blood unit in 2005 to 2016. A cord blood unit search was evaluated to identify units with equal or greater human leukocyte antigen matching and a greater total nucleated cell count than that of the transplanted cord blood unit (the replacement cord blood unit). If the minimum total nucleated cell count for banking increased to 124 or 149 × 10 7 , then from 75 to 80% of patients would still have at least 1 replacement cord blood unit in the current (2016) cord blood unit inventory. The best replacement cord blood units were often found among cords with the same ethnic background as the patient. The current data suggest that, if the minimum total nucleated cell count were increased for banking, then it would likely lead to an inventory of more desirable cord blood units while having minimal impact on the identification of suitable cord blood units for transplantation. © 2017 AABB.
Risk of Suicide Attempt Associated with Previous Attempts in One’s Army Unit
Ursano, Robert J.; Kessler, Ronald C.; Naifeh, James A.; Mash, Holly Herberman; Fullerton, Carol S.; Bliese, Paul D.; Zaslavsky, Alan M.; Ng, Tsz Hin Hinz; Aliaga, Pablo A.; Wynn, Gary H.; Dinh, Hieu M.; McCarroll, James E.; Sampson, Nancy A.; Kao, Tzu-Cheg; Schoenbaum, Michael; Heeringa, Steven G.; Stein, Murray B.
2017-01-01
Objective Soldiers’ mental health is adversely affected by the death and injury of other unit members, but it is not known if risk of suicide attempt is influenced by previous suicide attempts in one’s unit. Method Using administrative data from the Army Study to Assess Risk and Resilience in Servicemembers (Army STARRS), we identified person-month records for all active duty Regular Army enlisted soldiers who attempted suicide from 2004–2009 (n=9,650) and an equal-probability sample of control person-months (n=153,528). Logistic regression analyses examined the number of past-year suicide attempts in one’s unit as a predictor of subsequent suicide attempt, controlling for socio-demographics, service-related characteristics, prior mental health diagnosis, and other unit variables, including suicide-, combat-, and accident-related unit deaths. We also examined whether the influence of previous unit suicide attempts varied by military occupational specialty (MOS) and unit size. Results In adjusted models, soldiers were more likely to attempt suicide if one or more suicide attempts occurred in their unit during the past year (OR=1.4–2.3; p<0.001), with odds increasing as the number of unit attempts increased. The odds of suicide attempt among soldiers in a unit with five or more past-year attempts was more than twice that of soldiers in a unit with no previous attempts (OR=2.3; 95% CI=2.1–2.6). The association of previous unit suicide attempts with subsequent risk was significant whether soldiers had a combat arms MOS or other MOS (OR=1.4–2.3; p<0.001). It was also significant regardless of unit size, with the highest risk for those in smaller units (1–40 soldiers) (OR=2.1–5.9; p<0.001). The population-attributable risk proportion for one or more unit suicide attempts in the past year indicated that if this risk could be reduced to no unit attempts, 18.2% of attempts would not occur. Conclusions Soldiers’ risk of suicide attempt increased as the number of past-year suicide attempts within their unit increased. This was true for both combat arms and other MOSs, and for units of any size, but particularly for smaller units. Units with a history of suicide attempts may be important targets for preventive interventions. PMID:28746705
Military Guilty Plea Inquiry: Some Constitutional Considerations.
1987-01-01
Sanchez v. United States, 417 F. 2d 494 (5th Cir. 1969). Trujillo v. United States, 377 F. 2d 266 (5th Cir. 1967). 188 United States v. Baylin, 696 F. 2d...States, 412 F. 2d 189 (3rd Cir. 1969). 190 Sanchez v. United States, 572 F. 2d 210 (9th Cir. 1977). 191 United States v. Rivera-Ramirez, 715 F. 2d 453...1981). 360 United States v. Dawson, 10 M.J. 142 (CMA 1981). United States v. Connell, 13 M.J. 156 (CMA 1982). 361 United States v. Cifuentes , 11 M.J
1985-05-24
United States, MITI has restrained growth rates of three big makers— Toyota Motor Corp, Nissan Motor Co and Honda Motor Co—in the fiscal year that started...617,000 units and 544,000 units, respectively, the sources said. Toyota shipped 551,790 units and Nissan 487,040 units in fiscal 1984. Honda is...35,010 units and Isuzu 29,500 units by their own outlets. 60 Toyota and Nissan are each being allotted an identical raise of" 11.9 percent, to some
[Portable multi-purpose device for monitoring of physiological informations].
Tamura, T; Togawa, T
1983-05-01
Unconstrained system that measures physiological information as skin temperatures and heart rate per unit time of a human subject was developed. The system contained portable device included memory control unit, instrumentation unit, timer and batteries, read-out unit, test unit and verify unit. Total number of data and channels, and interval were selected by switches in the memory control unit. The data from the instrumentation unit were transferred to memory control unit and stored in the Erasable Programmable ROM (EPROM). After measurement, EPROM chip was taken off the memory control unit and put on the read-out unit which transferred the data to the microcomputer. The data were directly calculated and analyzed by microcomputer. In application of the instrumentation unit, 8-channel skin thermometer was developed and tested. After amplification, 8 analog signals were multiplexed and converted into the binary codes. The digital signals were sequentially transferred to memory control unit and stored in the EPROM under controlled signal. The accuracy of the system is determined primarily by the accuracy of the sensor of instrumentation unit. The overall accuracy of 8-channel skin thermometer is conservatively stated within 0.1 degree C. This may prove to be useful in providing an objective measurement of human subjects, and can be used in studying environmental effect for human body and sport activities in a large population setting.
Reactor vessel annealing system
Miller, Phillip E.; Katz, Leonoard R.; Nath, Raymond J.; Blaushild, Ronald M.; Tatch, Michael D.; Kordalski, Frank J.; Wykstra, Donald T.; Kavalkovich, William M.
1991-01-01
A system for annealing a vessel (14) in situ by heating the vessel (14) to a defined temperature, composed of: an electrically operated heater assembly (10) insertable into the vessel (14) for heating the vessel (14) to the defined temperature; temperature monitoring components positioned relative to the heater assembly (10) for monitoring the temperature of the vessel (14); a controllable electric power supply unit (32-60) for supplying electric power required by the heater assembly (10); a control unit (80-86) for controlling the power supplied by the power supply unit (32-60); a first vehicle (2) containing the power supply unit (32-60); a second vehicle (4) containing the control unit (80-86); power conductors (18,22) connectable between the power supply unit (32-60) and the heater unit (10) for delivering the power supplied by the power supply unit (32-60) to the heater assembly (10); signal conductors (20,24) connectable between the temperature monitoring components and the control unit (80-86) for delivering temperature indicating signals from the temperature monitoring components to the control unit (80-86); and control conductors (8) connectable between the control unit (80-86) and the power supply unit (32-60) for delivering to the power supply unit (32-60) control signals for controlling the level of power supplied by the power supply unit (32-60) to the heater assembly (10).
Task uncertainty and communication during nursing shift handovers.
Mayor, Eric; Bangerter, Adrian; Aribot, Myriam
2012-09-01
We explore variations in handover duration and communication in nursing units. We hypothesize that duration per patient is higher in units facing high task uncertainty. We expect both topics and functions of communication to vary depending on task uncertainty. Handovers are changing in modern healthcare organizations, where standardized procedures are increasingly advocated for efficiency and reliability reasons. However, redesign of handover should take environmental contingencies of different clinical unit types into account. An important contingency in institutions is task uncertainty, which may affect how communicative routines like handover are accomplished. Nurse unit managers of 80 care units in 18 hospitals were interviewed in 2008 about topics and functions of handover communication and duration in their unit. Interviews were content-analysed. Clinical units were classified into a theory-based typology (unit type) that gradually increases on task uncertainty. Quantitative analyses were performed. Unit type affected resource allocation. Unit types facing higher uncertainty had higher handover duration per patient. As expected, unit type also affected communication content. Clinical units facing higher uncertainty discussed fewer topics, discussing treatment and care and organization of work less frequently. Finally, unit type affected functions of handover: sharing emotions was less often mentioned in unit types facing higher uncertainty. Task uncertainty and its relationship with functions and topics of handover should be taken into account during the design of handover procedures. © 2011 Blackwell Publishing Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
Prior to 1978, the Wilsonville Advanced Coal Liquefaction facility material balance surrounded only the thermal liquefaction unit and involved analyses of only the slurry stream and individual gas streams. The distillate solvent yield was determined by difference. Subsequently, several modifications and additional process units were introduced to this single unit system. With the inclusion of the deashing unit in 1978 and the catalytic hydrogenation unit in 1981, the process has evolved into a sophisticated two-stage coal liquefaction process and has the potential for various modes of integration. This report presents an elemental balancing procedure and a simplified presentation format thatmore » is sufficiently flexible to meet current and future needs. The development of the elemental balancing technique and the relevant computer programs to handle the calculations have been addressed. This will be useful in modelling individual unit performance as well as determining the impact of each unit on the overall liquefaction system, provided the units are on a steady-state basis. Five different material balance envelopes are defined. Three of these envelopes pertain to the individual units (the thermal liquefaction or TL unit, the Critical Solvent Deashing or CSD unit and the H-Oil Ebullated Bed Hydrotreating or HTR unit). The fourth or single stage material balance envelope combines the TL and CSD units. The fifth envelope is the two-stage configuration combining all three units. 3 references.« less
Aetiology of obstructive azoospermia in Chinese infertility patients.
Han, H; Liu, S; Zhou, X-G; Tian, L; Zhang, X-D
2016-09-01
To explore the aetiology of obstructive azoospermia (OA) in Chinese infertility patients, 133 OA patients was included in this study diagnosed and evaluated by one major specialist trained urological infertility. We retrospected the medical records to collect relative information. All of the patients had been underwent physical examination, ultrasound scan to the urogenital system, serum hormone tests, genetic tests and two separate semen analyses. The mean age of all 133 patients was 32.7 ± 6.8 years. A total of 266 reproductive tract units (two/patient) were classified into four categories: no causes (Idiopathic) for 74 units (27.8%), single cause for 173 units (65.0%), double causes for 17 units (6.4%) and triple causes for two units (0.8%). As to single cause of OA, there were four types: trauma for 0 unit (0%), infection for 125 units (47.0%), dysplasia for 11 units (4.1%) and surgeries for 37 units (13.9%). As to total cause of OA, there were five types: infection for 144 units (54.1%), orchitis for 51 units (19.2%), epididymitis for 54 units (20.3%), gonorrhoea for 28 units (10.5%) and inguinal hernia repair surgery for 18 units (6.8%). The most frequent cause of obstructive azoospermia was infection revealed in these Chinese infertility populations, followed by idiopathic reason. © 2015 Blackwell Verlag GmbH.
7 CFR 1150.106 - United States.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 9 2011-01-01 2011-01-01 false United States. 1150.106 Section 1150.106 Agriculture... Order Definitions § 1150.106 United States. United States means the 48 contiguous States in the continental United States. ...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 3 2011-01-01 2011-01-01 false United States. 65.255 Section 65.255 Agriculture..., PEANUTS, AND GINSENG General Provisions Definitions § 65.255 United States. United States means the 50... United States. ...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 3 2012-01-01 2012-01-01 false United States. 65.255 Section 65.255 Agriculture..., PEANUTS, AND GINSENG General Provisions Definitions § 65.255 United States. United States means the 50... United States. ...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 3 2013-01-01 2013-01-01 false United States. 65.255 Section 65.255 Agriculture..., PEANUTS, AND GINSENG General Provisions Definitions § 65.255 United States. United States means the 50... United States. ...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 3 2014-01-01 2014-01-01 false United States. 65.255 Section 65.255 Agriculture..., PEANUTS, AND GINSENG General Provisions Definitions § 65.255 United States. United States means the 50... United States. ...
ERIC Educational Resources Information Center
Nelson, Robert A.
1983-01-01
Discusses legislation related to SI (International Systems of Units) in the United States. Indicates that although SI metric units have been officially recognized by law in the United States, U.S. Customary Units have never received a statutory basis. (JN)
7 CFR 1150.106 - United States.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 9 2010-01-01 2009-01-01 true United States. 1150.106 Section 1150.106 Agriculture... Order Definitions § 1150.106 United States. United States means the 48 contiguous States in the continental United States. ...
Code of Federal Regulations, 2011 CFR
2011-07-01
... for fluid catalytic cracking units (FCCU) and fluid coking units (FCU). 60.105a Section 60.105a... and operations for fluid catalytic cracking units (FCCU) and fluid coking units (FCU). (a) FCCU and... Emission Standards for Hazardous Air Pollutants for Petroleum Refineries: Catalytic Cracking Units...
Code of Federal Regulations, 2010 CFR
2010-07-01
... for fluid catalytic cracking units (FCCU) and fluid coking units (FCU). 60.105a Section 60.105a... and operations for fluid catalytic cracking units (FCCU) and fluid coking units (FCU). (a) FCCU and... Emission Standards for Hazardous Air Pollutants for Petroleum Refineries: Catalytic Cracking Units...
41 CFR 301-10.131 - What does United States mean?
Code of Federal Regulations, 2013 CFR
2013-07-01
... 41 Public Contracts and Property Management 4 2013-07-01 2012-07-01 true What does United States... Carrier Transportation Use of United States Flag Air Carriers § 301-10.131 What does United States mean? For purposes of the use of United States flag air carriers, United States means the 50 states, the...
41 CFR 301-10.131 - What does United States mean?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 41 Public Contracts and Property Management 4 2010-07-01 2010-07-01 false What does United States... Carrier Transportation Use of United States Flag Air Carriers § 301-10.131 What does United States mean? For purposes of the use of United States flag air carriers, United States means the 50 states, the...
41 CFR 301-10.131 - What does United States mean?
Code of Federal Regulations, 2011 CFR
2011-07-01
... 41 Public Contracts and Property Management 4 2011-07-01 2011-07-01 false What does United States... Carrier Transportation Use of United States Flag Air Carriers § 301-10.131 What does United States mean? For purposes of the use of United States flag air carriers, United States means the 50 states, the...
41 CFR 301-10.131 - What does United States mean?
Code of Federal Regulations, 2014 CFR
2014-07-01
... 41 Public Contracts and Property Management 4 2014-07-01 2014-07-01 false What does United States... Carrier Transportation Use of United States Flag Air Carriers § 301-10.131 What does United States mean? For purposes of the use of United States flag air carriers, United States means the 50 states, the...
The Methodist Hospital CCU: a Beacon unit of excellence.
Lewis, Tricia; Abanobi, Beatrice; Alleman, Paula; Ballinas, Eva; Botbyl, Brenda; Bries, Girlie; Clark, Liz; Clarkson, Terri; Cooper, Bridgette; Cooper, Jason; Cox, Shelly; Cude, Rebecca; Davis, Juanita; Delosreyes, Arlene; Durst, Kimberly; East, Ana; Edwards, Erving; Ellison, Rose; Eparwa, Perlita; Forjuoh, Harriet; Foster, Donald; Foytik, Lisa; Gordon, Maria; Grace, Jean; Green, Lisa; Harrison, Cassandra; Herrera, Rubin; Horn, Mary; Hunsinger, Cheryce; Issac, Annamma; Jackson, Valerie; Johnson, Athie; Kitayama, Susanna; Karaan, Juliet; Kezmarski, Mary; Kleinrock, Richard; Latson, Maria; Lee, Valerie; Long, Robin; Macapagal, Fred; Magsino, Diana; Manojkumar, Saleena; Martin, Denise; Matura, Lea Ann; McCarthy, Cynthia; McClellan, Emma; McDaniel, Christy; Mengo, Pam; Meurer, Judy; Muttathottil, Liz; Osayande, Esther; Osei-Frimpong, Diana; Phillips, Betty; Pittman, James; Pratt, Craig; Putney, David; Refuerzo, Laarni; Rendon, Lavinia; Richter, Russ; Simms, Sylvia; Sitoy, Diana; Small-Nelson, Judith; Sosa, Tomas; Stuckey, Denise; Tacquard, Natalie; Talbott, Sarah; Talladen, Aleine; Taylor, Shani; Thomas, Lini; Thompson, Pam; Walters, Gordon; West, Rachel
2005-06-01
This article features the Coronary Care Unit of The Methodist Hospital of Houston, Texas. This unit was one of the first Beacon Critical Care Units recognized by the American Association of Critical Care Nurses. This article focuses on how to achieve this award. The Coronary Care Unit nursing infrastructure is described, and specific unit examples are included.
The Antebellum Women's Movement, 1820 to 1860. A Unit of Study for Grades 8-11.
ERIC Educational Resources Information Center
Leighow, Susan; Sterner-Hine, Rita
Using primary source documents, this teaching unit focuses on changing women's roles, growing awareness of gender inequities, and activist responses to these conditions in the United States between 1820 and 1860. Teacher background materials include a unit overview, correlation to National Standards for United States History, unit objectives, a…
46 CFR 108.661 - Unit markings: Draft marks.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Unit markings: Draft marks. 108.661 Section 108.661... AND EQUIPMENT Equipment Markings and Instructions § 108.661 Unit markings: Draft marks. (a) Each unit must have draft marks for each foot of immersion— (1) If the unit is a surface unit, on both the port...
46 CFR 108.661 - Unit markings: Draft marks.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Unit markings: Draft marks. 108.661 Section 108.661... AND EQUIPMENT Equipment Markings and Instructions § 108.661 Unit markings: Draft marks. (a) Each unit must have draft marks for each foot of immersion— (1) If the unit is a surface unit, on both the port...
46 CFR 108.661 - Unit markings: Draft marks.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Unit markings: Draft marks. 108.661 Section 108.661... AND EQUIPMENT Equipment Markings and Instructions § 108.661 Unit markings: Draft marks. (a) Each unit must have draft marks for each foot of immersion— (1) If the unit is a surface unit, on both the port...
46 CFR 108.661 - Unit markings: Draft marks.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Unit markings: Draft marks. 108.661 Section 108.661... AND EQUIPMENT Equipment Markings and Instructions § 108.661 Unit markings: Draft marks. (a) Each unit must have draft marks for each foot of immersion— (1) If the unit is a surface unit, on both the port...
46 CFR 108.661 - Unit markings: Draft marks.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Unit markings: Draft marks. 108.661 Section 108.661... AND EQUIPMENT Equipment Markings and Instructions § 108.661 Unit markings: Draft marks. (a) Each unit must have draft marks for each foot of immersion— (1) If the unit is a surface unit, on both the port...
78 FR 70414 - Pricing for the 2013 United States Mint Limited Edition Silver Proof SetTM
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-25
... DEPARTMENT OF THE TREASURY United States Mint Pricing for the 2013 United States Mint Limited Edition Silver Proof Set TM AGENCY: United States Mint, Department of the Treasury. ACTION: Notice. SUMMARY: The United States Mint is announcing a price of $139.95 for the 2013 United States Mint Limited...
31 CFR 570.508 - Libyan diplomatic missions in the United States.
Code of Federal Regulations, 2013 CFR
2013-07-01
... missions of the Government of Libya to the United States and the United Nations is authorized, provided... the Government of Libya to the United States and the United Nations. (b) The provision of goods or services in the United States to the employees of the diplomatic missions of the Government of Libya to the...
31 CFR 570.508 - Libyan diplomatic missions in the United States.
Code of Federal Regulations, 2014 CFR
2014-07-01
... missions of the Government of Libya to the United States and the United Nations is authorized, provided... the Government of Libya to the United States and the United Nations. (b) The provision of goods or services in the United States to the employees of the diplomatic missions of the Government of Libya to the...
31 CFR 570.508 - Libyan diplomatic missions in the United States.
Code of Federal Regulations, 2012 CFR
2012-07-01
... missions of the Government of Libya to the United States and the United Nations is authorized, provided... the Government of Libya to the United States and the United Nations. (b) The provision of goods or services in the United States to the employees of the diplomatic missions of the Government of Libya to the...
31 CFR 570.508 - Libyan diplomatic missions in the United States.
Code of Federal Regulations, 2011 CFR
2011-07-01
... missions of the Government of Libya to the United States and the United Nations is authorized, provided... the Government of Libya to the United States and the United Nations. (b) The provision of goods or services in the United States to the employees of the diplomatic missions of the Government of Libya to the...
Intermediate SCDC Spanish Curricula Units. Science/Health, Unit 1, Kits 1-4, Teacher's Guide.
ERIC Educational Resources Information Center
Spanish Curricula Development Center, Miami Beach, FL.
Unified by the theme "our community", this unit, part of nine basic instructional units for intermediate level, reflects the observations of Mexican Americans, Puerto Ricans, and Cubans in various regions of the United States. Comprised of Kits 1-4, the unit extends the following basic and interpreted science processes: observing, communicating,…
40 CFR 60.1555 - Are any small municipal waste combustion units exempt from my State plan?
Code of Federal Regulations, 2011 CFR
2011-07-01
.../rubber recycling units. Units are exempt from your State plan if four requirements are met: (1) The pyrolysis/combustion unit is an integrated part of a plastics/rubber recycling unit as defined under... that combust fuels made from products of plastics/rubber recycling plants. Units are exempt from your...
40 CFR 62.15020 - Can my small municipal waste combustion unit be exempt from this subpart?
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Plastics/rubber recycling units. Your unit is exempt from this subpart if four requirements are met: (1) Your pyrolysis/combustion unit is an integrated part of a plastics/rubber recycling unit as defined... the feed stocks. (i) Units that combust fuels made from products of plastics/rubber recycling plants...
40 CFR 62.15020 - Can my small municipal waste combustion unit be exempt from this subpart?
Code of Federal Regulations, 2014 CFR
2014-07-01
...) Plastics/rubber recycling units. Your unit is exempt from this subpart if four requirements are met: (1) Your pyrolysis/combustion unit is an integrated part of a plastics/rubber recycling unit as defined... the feed stocks. (i) Units that combust fuels made from products of plastics/rubber recycling plants...
40 CFR 62.15020 - Can my small municipal waste combustion unit be exempt from this subpart?
Code of Federal Regulations, 2012 CFR
2012-07-01
...) Plastics/rubber recycling units. Your unit is exempt from this subpart if four requirements are met: (1) Your pyrolysis/combustion unit is an integrated part of a plastics/rubber recycling unit as defined... the feed stocks. (i) Units that combust fuels made from products of plastics/rubber recycling plants...
40 CFR 60.1555 - Are any small municipal waste combustion units exempt from my State plan?
Code of Federal Regulations, 2014 CFR
2014-07-01
.../rubber recycling units. Units are exempt from your State plan if four requirements are met: (1) The pyrolysis/combustion unit is an integrated part of a plastics/rubber recycling unit as defined under... that combust fuels made from products of plastics/rubber recycling plants. Units are exempt from your...
40 CFR 60.1555 - Are any small municipal waste combustion units exempt from my State plan?
Code of Federal Regulations, 2013 CFR
2013-07-01
.../rubber recycling units. Units are exempt from your State plan if four requirements are met: (1) The pyrolysis/combustion unit is an integrated part of a plastics/rubber recycling unit as defined under... that combust fuels made from products of plastics/rubber recycling plants. Units are exempt from your...
40 CFR 60.1555 - Are any small municipal waste combustion units exempt from my State plan?
Code of Federal Regulations, 2010 CFR
2010-07-01
.../rubber recycling units. Units are exempt from your State plan if four requirements are met: (1) The pyrolysis/combustion unit is an integrated part of a plastics/rubber recycling unit as defined under... that combust fuels made from products of plastics/rubber recycling plants. Units are exempt from your...
40 CFR 60.1555 - Are any small municipal waste combustion units exempt from my State plan?
Code of Federal Regulations, 2012 CFR
2012-07-01
.../rubber recycling units. Units are exempt from your State plan if four requirements are met: (1) The pyrolysis/combustion unit is an integrated part of a plastics/rubber recycling unit as defined under... that combust fuels made from products of plastics/rubber recycling plants. Units are exempt from your...
40 CFR 62.15020 - Can my small municipal waste combustion unit be exempt from this subpart?
Code of Federal Regulations, 2011 CFR
2011-07-01
...) Plastics/rubber recycling units. Your unit is exempt from this subpart if four requirements are met: (1) Your pyrolysis/combustion unit is an integrated part of a plastics/rubber recycling unit as defined... the feed stocks. (i) Units that combust fuels made from products of plastics/rubber recycling plants...
40 CFR 62.15020 - Can my small municipal waste combustion unit be exempt from this subpart?
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Plastics/rubber recycling units. Your unit is exempt from this subpart if four requirements are met: (1) Your pyrolysis/combustion unit is an integrated part of a plastics/rubber recycling unit as defined... the feed stocks. (i) Units that combust fuels made from products of plastics/rubber recycling plants...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 9 2013-07-01 2013-07-01 false Municipal Waste Combustor Units (MWC... FOR DESIGNATED FACILITIES AND POLLUTANTS Federal Plan Requirements for Large Municipal Waste... Part 62—Municipal Waste Combustor Units (MWC Units) Excluded From Subpart FFF 1 State MWC units Alabama...
Aquatic Activities for Middle School Children. A Focus on the Effects of Acid Precipitation.
ERIC Educational Resources Information Center
Minnesota Univ., Minneapolis. Minnesota Sea Grant Program.
Basic water-related concepts and underlying principles of acid rain are described in this curriculum in a manner that young children can understand. The curriculum consists of activities presented in four units: Background Unit, Earth Science Unit, Life Science Unit, and Extension Unit. The first three units consist of several modules, each module…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-15
...] United States Department of Energy and United States Department of Defense v. Baltimore & Ohio Railroad..., 2012, United States Department of Energy and the United States Department of Defense (the Government...) Terrance A. Spann, U.S. Department of Defense, 9275 Gunston Road, Suite 1300, Fort Belvoir, VA 22060; and...
75 FR 10345 - Pricing for 2010 United States Mint America the Beautiful Quarters Proof Set, etc.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-05
... DEPARTMENT OF THE TREASURY United States Mint Pricing for 2010 United States Mint America the.... SUMMARY: The United States Mint is announcing the prices of the 2010 United States Mint America the Beautiful Quarters Proof Set; 2010 United States Mint America the Beautiful Quarters Silver Proof Set; 2010...
40 CFR Table 29 to Subpart Uuu of... - HAP Emission Limits for Sulfur Recovery Units
Code of Federal Regulations, 2014 CFR
2014-07-01
... Recovery Units 29 Table 29 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION... Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 29 Table 29 to Subpart UUU of Part 63—HAP Emission Limits for Sulfur Recovery Units As stated in...
40 CFR Table 22 to Subpart Uuu of... - Inorganic HAP Emission Limits for Catalytic Reforming Units
Code of Federal Regulations, 2011 CFR
2011-07-01
... Catalytic Reforming Units 22 Table 22 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL... Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 22 Table 22 to Subpart UUU of Part 63—Inorganic HAP Emission Limits for Catalytic Reforming Units...
40 CFR Table 22 to Subpart Uuu of... - Inorganic HAP Emission Limits for Catalytic Reforming Units
Code of Federal Regulations, 2010 CFR
2010-07-01
... Catalytic Reforming Units 22 Table 22 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL... Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 22 Table 22 to Subpart UUU of Part 63—Inorganic HAP Emission Limits for Catalytic Reforming Units...
40 CFR Table 8 to Subpart Uuu of... - Organic HAP Emission Limits for Catalytic Cracking Units
Code of Federal Regulations, 2011 CFR
2011-07-01
... Catalytic Cracking Units 8 Table 8 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL... Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 8 Table 8 to Subpart UUU of Part 63—Organic HAP Emission Limits for Catalytic Cracking Units As...
40 CFR Table 8 to Subpart Uuu of... - Organic HAP Emission Limits for Catalytic Cracking Units
Code of Federal Regulations, 2010 CFR
2010-07-01
... Catalytic Cracking Units 8 Table 8 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL... Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 8 Table 8 to Subpart UUU of Part 63—Organic HAP Emission Limits for Catalytic Cracking Units As...
40 CFR Table 29 to Subpart Uuu of... - HAP Emission Limits for Sulfur Recovery Units
Code of Federal Regulations, 2012 CFR
2012-07-01
... Recovery Units 29 Table 29 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION... Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 29 Table 29 to Subpart UUU of Part 63—HAP Emission Limits for Sulfur Recovery Units As stated in...
40 CFR Table 15 to Subpart Uuu of... - Organic HAP Emission Limits for Catalytic Reforming Units
Code of Federal Regulations, 2010 CFR
2010-07-01
... Catalytic Reforming Units 15 Table 15 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL... Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 15 Table 15 to Subpart UUU of Part 63—Organic HAP Emission Limits for Catalytic Reforming Units As...
40 CFR Table 15 to Subpart Uuu of... - Organic HAP Emission Limits for Catalytic Reforming Units
Code of Federal Regulations, 2011 CFR
2011-07-01
... Catalytic Reforming Units 15 Table 15 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL... Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 15 Table 15 to Subpart UUU of Part 63—Organic HAP Emission Limits for Catalytic Reforming Units As...
Zabeen, Sara; Tsourtos, George; Campion, Jonathan; Lawn, Sharon
2015-11-01
Globally, smoking remains a significant issue for mental health populations. Many mental health trusts in England are facing challenges of implementing the National Institute for Health and Care Excellence guidance according to which all mental health settings, no matter the type, should be entirely smoke-free and provide comprehensive smoking cessation support. The aim of this paper was to determine if unit type and unit manager smoking status influence mental health smoke-free policy implementation. This paper reports on the secondary analysis of data from a cross-sectional survey of 147 mental health inpatient settings in England, in 2010. The original study's main aim was to understand unit managers' perceived reasons for success or failure of smoke-free policy. Unit managers (n = 131) held a positive stance towards supporting smoke-free policy and most perceived that the policy was successful. Non-smoker unit managers were more likely to adopt complete bans than smoker unit managers, whereas smoker unit managers were more likely than non-smoker unit managers to think that stopping smoking aggravated patients' mental illness. Smoking rates for staff and patients remain high, as perceived by unit managers, regardless of unit type. Proportion of units offering nicotine replacement therapy and peer support to patients was significantly higher in locked units compared to semi-locked or residential rehabilitation. Applied strategies significantly vary by type of unit, whereas unit managers' knowledge, attitude and practices vary by their smoking status. There are nuanced differences in how smoke-free policy is enacted which vary by unit type. These variations recognise the differing contexts of care provision in different types of units serving different patient groups. Addressing staff smoking rates, promoting consistency of staff response to patients' smoking and providing staff education and support continue to be key strategies to successful smoke-free policy. Our results demonstrate the importance of taking into account the type of unit and acuity of patients when enacting smoke-free policy and addressing staff smoking. © The Author(s) 2015.
Nursing Unit Design, Nursing Staff Communication Networks, and Patient Falls: Are They Related?
Brewer, Barbara B; Carley, Kathleen M; Benham-Hutchins, Marge; Effken, Judith A; Reminga, Jeffrey
2018-01-01
The purpose of this research is to (1) investigate the impact of nursing unit design on nursing staff communication patterns and, ultimately, on patient falls in acute care nursing units; and (2) evaluate whether differences in fall rates, if found, were associated with the nursing unit physical structure (shape) or size. Nursing staff communication and nursing unit design are frequently linked to patient safety outcomes, yet little is known about the impact of specific nursing unit designs on nursing communication patterns that might affect patient falls. An exploratory longitudinal correlational design was used to measure nursing unit communication structures using social network analysis techniques. Data were collected 4 times over a 7-month period. Floor plans were used to determine nursing unit design. Fall rates were provided by hospital coordinators. An analysis of covariance controlling for hospitals resulted in a statistically significant interaction of unit shape and size (number of beds). The interaction occurred when medium- and large-sized racetrack-shaped units intersected with medium- and large-sized cross-shaped units. The results suggest that nursing unit design shape impacts nursing communication patterns, and the interaction of shape and size may impact patient falls. How those communication patterns affect patient falls should be considered when planning hospital construction of nursing care units.
The Design of Adult Acute Care Units in U.S. Hospitals
Catrambone, Cathy; Johnson, Mary E.; Mion, Lorraine C.; Minnick, Ann F.
2010-01-01
Purpose To describe the current state of design characteristics determined to be desirable by the Agency for Health Research and Quality (AHRQ) in U.S. adult medical, surgical, and intensive care units (ICUs). Design Descriptive study of patient visibility; distance to hygiene, toileting, charting, and supplies; unit configuration; percentage of private rooms; and presence or absence of carpeting in 56 ICUs and 81 medical-surgical units in six metropolitan areas. Methods Data were collected via observation, measurement, and interviews. Unit configurations were classified via an iterative process. Descriptive data were analyzed according to ICU and non-ICU status using SPSS (Version 15). Findings Analysis of unit configurations indicated eight unit designs. Statistical analysis showed inter- and intrahospital variation in unit configurations, percentage private rooms, carpeting, visibility, and distance to supplies and charting. Few units met the AHRQ designated design elements studied. Conclusions A wide gap exists between desirable characteristics in ICUs and medical-surgical units. Future research is needed to explore operationalization of unit design elements as risk adjustments, how design elements contribute to patient outcomes, and how design elements influence one another. Clinical Relevance There is room for improvement on almost every design variable, particularly on medical-surgical units. Future planning should take into consideration the interaction of bed capacity and unit configuration. PMID:19335681
Mathematical structure of unit systems
NASA Astrophysics Data System (ADS)
Kitano, Masao
2013-05-01
We investigate the mathematical structure of unit systems and the relations between them. Looking over the entire set of unit systems, we can find a mathematical structure that is called preorder (or quasi-order). For some pair of unit systems, there exists a relation of preorder such that one unit system is transferable to the other unit system. The transfer (or conversion) is possible only when all of the quantities distinguishable in the latter system are always distinguishable in the former system. By utilizing this structure, we can systematically compare the representations in different unit systems. Especially, the equivalence class of unit systems (EUS) plays an important role because the representations of physical quantities and equations are of the same form in unit systems belonging to an EUS. The dimension of quantities is uniquely defined in each EUS. The EUS's form a partially ordered set. Using these mathematical structures, unit systems and EUS's are systematically classified and organized as a hierarchical tree.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This is the RCRA required permit application for Radioactive and Hazardous Waste Management at the Oak Ridge Y-12 Plant for the following units: Building 9206 Container Storage Unit; Building 9212 Container Storage Unit; Building 9720-12 Container Storage Unit; Cyanide Treatment Unit. All four of these units are associated with the recovery of enriched uranium and other metals from wastes generated during the processing of nuclear materials.
Mathur, Aabhas; Chowdhury, Raquibul; Hillyer, Christopher D; Mitchell, W Beau; Shaz, Beth H
2016-12-01
Each unit of blood donated is processed and stored individually resulting in variability in the amount of red blood cells (RBCs) collected, RBC properties, and the 24-hour posttransfusion RBC survivability. As a result, each unit differs in its ability to deliver oxygen and potentially its effects on the recipient. The goal of this study was to investigate the storage of pooled RBCs from multiple donors in comparison to control standard RBC units. Two units of irradiated, leukoreduced RBCs of same ABO, D, E, C, and K antigen phenotype were collected from each of five donors using apheresis. One unit from each donor was pooled in a 2-L bag and remaining units were used as controls. After being pooled, RBCs were separated in five bags and stored at 4°C along with the controls. Quality indexes were measured on Days 2, 14, and 28 for all the units. Adenosine triphosphate assays for both pooled and controls showed a slight decrease from Day 2 to Day 28 (pooled/control from 5.22/5.24 to 4.35/4.33 µmol/g hemoglobin [Hb]). 2,3-Diphosphoglycerate was successfully rejuvenated for all RBC units on Day 28 (pooled 11.46 µmol/g Hb; control 11.86 µmol/g Hb). The results showed a nonsignificant difference between pooled and control units, with a general trend of lower standard deviation for pooled units when compared to controls. Pooled units have reduced unit-to-unit variability. Future exploration of their immunogenicity is required before using pooled units for transfusion. © 2016 AABB.
Firing patterns of spontaneously active motor units in spinal cord-injured subjects.
Zijdewind, Inge; Thomas, Christine K
2012-04-01
Involuntary motor unit activity at low rates is common in hand muscles paralysed by spinal cord injury. Our aim was to describe these patterns of motor unit behaviour in relation to motoneurone and motor unit properties. Intramuscular electromyographic activity (EMG), surface EMG and force were recorded for 30 min from thenar muscles of nine men with chronic cervical SCI. Motor units fired for sustained periods (>10 min) at regular (coefficient of variation ≤ 0.15, CV, n =19 units) or irregular intervals (CV>0.15, n =14). Regularly firing units started and stopped firing independently suggesting that intrinsic motoneurone properties were important for recruitment and derecruitment. Recruitment (3.6 Hz, SD 1.2), maximal (10.2 Hz, SD 2.3, range: 7.5-15.4 Hz) and derecruitment frequencies were low (3.3 Hz, SD 1.6), as were firing rate increases after recruitment (~20 intervals in 3 s). Once active, firing often covaried, promoting the idea that units received common inputs.Half of the regularly firing units showed a very slow decline (>40 s) in discharge before derecruitment and had interspike intervals longer than their estimated after hyperpolarisation potential (AHP) duration (estimated by death rate and breakpoint analyses). The other units were derecruited more abruptly and had shorter estimated AHP durations. Overall, regularly firing units had longer estimated AHP durations and were weaker than irregularly firing units, suggesting they were lower threshold units. Sustained firing of units at regular rates may reflect activation of persistent inward currents, visible here in the absence of voluntary drive, whereas irregularly firing units may only respond to synaptic noise.
7 CFR 1212.31 - United States.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 10 2013-01-01 2013-01-01 false United States. 1212.31 Section 1212.31 Agriculture..., Consumer Education, and Industry Information Order Definitions § 1212.31 United States. “United States... territories and possessions of the United States. ...
7 CFR 1212.31 - United States.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 10 2012-01-01 2012-01-01 false United States. 1212.31 Section 1212.31 Agriculture..., Consumer Education, and Industry Information Order Definitions § 1212.31 United States. “United States... territories and possessions of the United States. ...
7 CFR 1212.31 - United States.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 10 2014-01-01 2014-01-01 false United States. 1212.31 Section 1212.31 Agriculture..., Consumer Education, and Industry Information Order Definitions § 1212.31 United States. “United States... territories and possessions of the United States. ...
7 CFR 1217.30 - United States.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 10 2012-01-01 2012-01-01 false United States. 1217.30 Section 1217.30 Agriculture..., and Industry Information Order Definitions § 1217.30 United States. United States means collectively... possessions of the United States. Softwood Lumber Board ...
7 CFR 1217.30 - United States.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 10 2014-01-01 2014-01-01 false United States. 1217.30 Section 1217.30 Agriculture..., and Industry Information Order Definitions § 1217.30 United States. United States means collectively... possessions of the United States. Softwood Lumber Board ...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 3 2011-01-01 2011-01-01 false United States. 63.13 Section 63.13 Agriculture... IMPROVEMENT CENTER General Provisions Definitions § 63.13 United States. United States means collectively the... possessions of the United States. Board of Directors ...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 3 2012-01-01 2012-01-01 false United States. 63.13 Section 63.13 Agriculture... IMPROVEMENT CENTER General Provisions Definitions § 63.13 United States. United States means collectively the... possessions of the United States. Board of Directors ...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 3 2014-01-01 2014-01-01 false United States. 63.13 Section 63.13 Agriculture... IMPROVEMENT CENTER General Provisions Definitions § 63.13 United States. United States means collectively the... possessions of the United States. Board of Directors ...
7 CFR 1217.30 - United States.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 10 2013-01-01 2013-01-01 false United States. 1217.30 Section 1217.30 Agriculture..., and Industry Information Order Definitions § 1217.30 United States. United States means collectively... possessions of the United States. Softwood Lumber Board ...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 3 2013-01-01 2013-01-01 false United States. 63.13 Section 63.13 Agriculture... IMPROVEMENT CENTER General Provisions Definitions § 63.13 United States. United States means collectively the... possessions of the United States. Board of Directors ...
7 CFR 1212.31 - United States.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 10 2010-01-01 2010-01-01 false United States. 1212.31 Section 1212.31 Agriculture..., Consumer Education, and Industry Information Order Definitions § 1212.31 United States. “United States... territories and possessions of the United States. ...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-22
...], and 2013 United States Mint Congratulations Set AGENCY: United States Mint, Department of the Treasury..., and the 2013 United States Mint Congratulations Set. 2012 and 2013 United States Mint America the... Silver Proof Set will be offered for sale at a price of $60.95. 2013 United States Mint Congratulations...
Svensson, Erik; Jensen, Elsebeth Tvenstrup; Rasmussen, Erik Michael; Folkvardsen, Dorte Bek; Norman, Anders; Lillebaek, Troels
2017-03-01
Mycobacterium chimaera was present at high rates (>80%) in heater-cooler units (HCUs) from all 5 thoracic surgery departments in Denmark. Isolates were clonal to HCU-associated isolates from the United States (including some from patients) and United Kingdom. However, M. chimaera from 2 brands of HCU were genetically distinct.
Code of Federal Regulations, 2010 CFR
2010-01-01
... in the United States from Canada; special procedures. 252.3 Section 252.3 Aliens and Nationality... and tugboats arriving in the United States from Canada; special procedures. (a) United States vessels... vessel of United States registry or a tugboat of United States registry arriving from Canada at a port of...
22 CFR 120.34 - Defense Trade Cooperation Treaty between the United States and the United Kingdom.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 22 Foreign Relations 1 2013-04-01 2013-04-01 false Defense Trade Cooperation Treaty between the United States and the United Kingdom. 120.34 Section 120.34 Foreign Relations DEPARTMENT OF STATE INTERNATIONAL TRAFFIC IN ARMS REGULATIONS PURPOSE AND DEFINITIONS § 120.34 Defense Trade Cooperation Treaty between the United States and the United...
Goertz, R.C.; Grimson, J.H.; Kohut, F.A.
1961-04-01
A remote-control manipulator comprising two stationary master units, two slave units on a movable vehicle, and electrical connections between the master and slave units is reported. The slave units are side by side with a minimum over-all width, which is made feasible by an arrangement of transducers producing most movements of each slave unit to one side of the support of said slave unit.
Effects of Infrastructure on Ebola Viral Disease
2016-06-10
Qualitative Case Study Comparison examining information from the World Health Organization, the United Nations, US Army Africa Operation United...Sierra Leone since the EVD outbreaks of 2013 to 2015. The study is a Qualitative Case Study Comparison examining information from the World Health...United Nations US United States USAID United States Agency for International Development USARAF United States Army Africa WHO World Health
22 CFR 46.3 - Aliens whose departure is deemed prejudicial to the interests of the United States.
Code of Federal Regulations, 2010 CFR
2010-04-01
... United States or the United Nations for the defense of any other country. (c) Any alien who seeks to... Forces of the United States and who fails to present a Registration Certificate (SSS Form No. 2) showing... defensive operations of the United States or of any nation cooperating with the United States in the...
40 CFR Table 29 to Subpart Uuu of... - HAP Emission Limits for Sulfur Recovery Units
Code of Federal Regulations, 2013 CFR
2013-07-01
... Units 29 Table 29 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 29 Table 29 to Subpart UUU of Part 63—HAP Emission Limits for Sulfur Recovery Units As stated in § 63.1568...
40 CFR Table 29 to Subpart Uuu of... - HAP Emission Limits for Sulfur Recovery Units
Code of Federal Regulations, 2011 CFR
2011-07-01
... Units 29 Table 29 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 29 Table 29 to Subpart UUU of Part 63—HAP Emission Limits for Sulfur Recovery Units As stated in § 63.1568(a)(1...
40 CFR Table 29 to Subpart Uuu of... - HAP Emission Limits for Sulfur Recovery Units
Code of Federal Regulations, 2010 CFR
2010-07-01
... Units 29 Table 29 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 29 Table 29 to Subpart UUU of Part 63—HAP Emission Limits for Sulfur Recovery Units As stated in § 63.1568(a)(1...
2013-01-01
Background Undernutrition is widespread among institutionalised elderly, and people suffering from dementia are at particularly high risk. Many elderly with dementia live in open units or in special care units in nursing homes. It is not known whether special care units have an effect on the nutritional status of the residents. The aim of this study was therefore to examine the nutritional status of residents with dementia in both open units and in special care units. Methods Among Oslo’s 29 municipal nursing homes, 21 participated with 358 residents with dementia or cognitive impairment, of which 46% lived in special care units. Nutritional status was assessed using the Malnutrition Universal Screening Tool and anthropometry. Results We found no differences (p > 0.05) in risk of undernutrition, body mass index, mid-upper arm muscle circumference or triceps skinfold thickness between residents in open units and those in special care units. Residents in special care units were significantly younger and stronger when measured with a hand-grip test. Conclusions We found no difference in nutritional status between nursing home residents with dementia/cognitive impairment in open units versus in special care units. PMID:23496975
[Unit cost variation in a social security company in Querétaro, México].
Villarreal-Ríos, Enrique; Campos-Esparza, Maribel; Garza-Elizondo, María E; Martínez-González, Lidia; Núñez-Rocha, Georgina M; Romero-Islas, Nestor R
2006-01-01
Comparing unit cost variation between departments and reasons for consultation in outpatient health services provided by a social security company from Querétaro, Mexico. A study of costs (in US dollars) was carried out in outpatient health service units during 2004. Fixed unit costs were estimated per department and adjusted for one year's productivity. Material, physical and consumer resources were included. Weighting was assigned to resources invested in each department. Unit cost was estimated by using the micro cost technique; medicaments, materials used during treatment and reagents were considered to be consumer items. Unit cost resulted from adding fixed unit cost to the variable unit cost corresponding to the reason for consulting. Units costs were then compared between the medical units. Unit cost per month for diabetic treatment varied from 34.8 US dollars, 32,2 US dollars to US 34 US dollars, pap smear screening test costs were 7,2 US dollars, 8,7 US dollars and 7,3 US dollars and dental treatment 27 US dollars, 33 US dollars, 6 and 28,7 US dollars. Unit cost variation was more important in the emergency room and the dental service.
NASA Technical Reports Server (NTRS)
Parker, T. J.; Pieri, D. C.
1985-01-01
In assessing the relative ages of the geomorphic/geologic units, crater counts of the entire unit or nearly the entire unit were made and summed in order to get a more accurate value than obtainable by counts of isolated sections of each unit. Cumulative size-frequency counts show some interesting relationships. Most of the units show two distinct crater populations with a flattening out of the distribution curve at and below 10 km diameter craters. Above this crater size the curves for the different units diverge most notably. In general, the variance may reflect the relative ages of these units. At times, however, in the larger crater size range, these curves can overlap and cross on another. Also the error bars at these larger sizes are broader (and thus more suspect), since counts of larger craters show more scatter, whereas the unit areas remain constant. Occasional clusters of relatively large craters within a given unit, particularly one of limited areal extent, can affect the curve so that the unit might seem to be older than units which it overlies or cuts.
Shu, Qin; Cai, Miao; Tao, Hong-bing; Cheng, Zhao-hui; Chen, Jing; Hu, Yin-huan; Li, Gang
2015-01-01
Abstract The objective of this study was to examine the strengths and weaknesses of surgical units as compared with other units, and to provide an opportunity to improve patient safety culture in surgical settings by suggesting targeted actions using Hospital Survey on Patient Safety Culture (HSOPSC) investigation. A Hospital Survey on Patient Safety questionnaire was conducted to physicians and nurses in a tertiary hospital in Shandong China. 12 patient safety culture dimensions and 2 outcome variables were measured. A total of 23.5% of respondents came from surgical units, and 76.5% worked in other units. The “overall perceptions of safety” (48.1% vs 40.4%, P < 0.001) and “frequency of events reported” (63.7% vs 60.7%, P = 0.001) of surgical units were higher than those of other units. However, the communication openness (38.7% vs 42.5%, P < 0.001) of surgical units was lower than in other units. Medical workers in surgical units reported more events than those in other units, and more respondents in the surgical units assess “patient safety grade” to be good/excellent. Three dimensions were considered as strengths, whereas 5 other dimensions were considered to be weaknesses in surgical units. Six dimensions have potential to aid in improving events reporting and patient safety grade. Appropriate working times will also contribute to ensuring patient safety. Medical staff with longer years of experience reported more events. Surgical units outperform the nonsurgical ones in overall perception of safety and the number of events reported but underperform in the openness of communication. Four strategies, namely deepening the understanding about patient safety of supervisors, narrowing the communication gap within and across clinical units, recruiting more workers, and employing the event reporting system and building a nonpunitive culture, are recommended to improve patient safety in surgical units in the context of 1 hospital. PMID:26166083
Shu, Qin; Cai, Miao; Tao, Hong-Bing; Cheng, Zhao-Hui; Chen, Jing; Hu, Yin-Huan; Li, Gang
2015-07-01
The objective of this study was to examine the strengths and weaknesses of surgical units as compared with other units, and to provide an opportunity to improve patient safety culture in surgical settings by suggesting targeted actions using Hospital Survey on Patient Safety Culture (HSOPSC) investigation.A Hospital Survey on Patient Safety questionnaire was conducted to physicians and nurses in a tertiary hospital in Shandong China. 12 patient safety culture dimensions and 2 outcome variables were measured.A total of 23.5% of respondents came from surgical units, and 76.5% worked in other units. The "overall perceptions of safety" (48.1% vs 40.4%, P < 0.001) and "frequency of events reported" (63.7% vs 60.7%, P = 0.001) of surgical units were higher than those of other units. However, the communication openness (38.7% vs 42.5%, P < 0.001) of surgical units was lower than in other units. Medical workers in surgical units reported more events than those in other units, and more respondents in the surgical units assess "patient safety grade" to be good/excellent. Three dimensions were considered as strengths, whereas 5 other dimensions were considered to be weaknesses in surgical units. Six dimensions have potential to aid in improving events reporting and patient safety grade. Appropriate working times will also contribute to ensuring patient safety. Medical staff with longer years of experience reported more events.Surgical units outperform the nonsurgical ones in overall perception of safety and the number of events reported but underperform in the openness of communication. Four strategies, namely deepening the understanding about patient safety of supervisors, narrowing the communication gap within and across clinical units, recruiting more workers, and employing the event reporting system and building a nonpunitive culture, are recommended to improve patient safety in surgical units in the context of 1 hospital.
Meso to Neoproterozoic layered mafic-ultramafic rocks from the Virorco back-arc intrusion, Argentina
NASA Astrophysics Data System (ADS)
Ferracutti, Gabriela; Bjerg, Ernesto; Hauzenberger, Christoph; Mogessie, Aberra; Cacace, Francisco; Asiain, Lucía
2017-11-01
The Virorco layered mafic-ultramafic intrusion is part of a belt that extends over 100 km from NE to SW in the Eastern Sierras Pampeanas of San Luis, Argentina. The rocks of this belt carry a Fe-Cu-Ni sulphide mineralization in veins and as disseminated and massive ore. Platinum group minerals are associated with the sulphides. The Virorco intrusion exhibits modal, textural and cryptic layering. New results allow the characterization of six layered units (Modal Layered Unit, Pyroxenitic Macro-Layered Unit, Gabbroic Unit, Banded Unit, Hornblende Norite Unit and Gabbronorite Unit) present in three sectors of the intrusion (Eastern, Central and Western). The units from the Western Sector (Banded Unit, Hornblende Norite Unit and Gabbronorite Unit) and the Modal Layered Unit from the Eastern Sector belong to the Marginal Border Series of the intrusion. Meanwhile, the Central sector units (Pyroxenitic Macro-Layered Unit and Gabbroic Unit) are from the Layered Series. The presence of crescumulate texture (Modal Layered Unit) and colloform banding (Banded Unit) are evidences of "in situ" crystallization due to supercooling of a MgO-rich hydrated mafic magma, where cooling proceeded from the walls towards the interior of the magma chamber. In previous studies the mafic-ultramafic rocks have been considered to be Cambrian to Ordovician. Here we present a Sm-Nd whole rock isochron which shows that the formation age of these intrusions is 1002 ± 150 Ma and that the protolith age of the Pringles Metamorphic Complex metasedimentary rocks is 1289 ± 97 Ma. Our study also indicates that the San Luis mafic-ultramafic layered intrusives most probably formed in a back-arc tectonic setting, from an enriched sub-continental mantle, influenced by a subducting slab and/or crust injection into the Pampia Terrane prior to its collision with the Rio de la Plata Craton.
Independence of motor unit recruitment and rate modulation during precision force control.
Kamen, G; Du, D C
1999-01-01
The vertebrate motor system chiefly employs motor unit recruitment and rate coding to modulate muscle force output. In this paper, we studied how the recruitment of new motor units altered the firing rate of already-active motor units during precision force production in the first dorsal interosseous muscle. Six healthy adults performed linearly increasing isometric voluntary contractions while motor unit activity and force output were recorded. After motor unit discharges were identified, motor unit firing rates were calculated before and after the instances of new motor unit recruitment. Three procedures were applied to compute motor unit firing rate, including the mean of a fixed number of inter-spike intervals and the constant width weighted Hanning window filter method, as well as a modified boxcar technique. In contrast to previous reports, the analysis of the firing rates of over 200 motor units revealed that reduction of the active firing rates was not a common mechanism used to accommodate the twitch force produced by the recruitment of a new motor unit. Similarly, during de-recruitment there was no tendency for motor unit firing rates to increase immediately following the cessation of activity in other motor units. Considerable consistency in recruitment behavior was observed during repeated contractions. However, firing rates during repeated contractions demonstrated considerably more fluctuation. It is concluded that the neuromuscular system does not use short-term preferential motor unit disfacilitation to effect precise regulation of muscular force output.
Tonometer disinfection practice in the United Kingdom: a national survey.
Hillier, R J; Kumar, N
2008-08-01
To assess current tonometer disinfection practice in the UK, and compare with published recommendations. Every ophthalmology unit with training recognition in the UK was contacted (n=155). A senior nurse at each institution completed a telephone questionnaire regarding local tonometer disinfection practice. The response rate was 100%. Thirty-five units (23%) reported exclusive use of disposable tonometer heads and were excluded from further analysis. One hundred and twenty units (77%) used either reusable or a combination of reusable and disposable tonometer heads. Where reusable heads were used, 80 units (67%) immersed them in a chlorine-based solution such as sodium hypochlorite or sodium dichloroisocyanurate. Others used isopropyl alcohol (18 units), hydrogen peroxide (12 units), chloramine (5 units), chlorhexidine (4 units) and peracetic acid (1 unit). Where a chlorine-based agent was used, the concentration of available chlorine ranged from 125 to 30 000 p.p.m., with 50 units (63%) using a concentration of less than 5 000 p.p.m. (i.e., inadequate based on published recommendations). Where the tonometer head was immersed in disinfectant between patients (n=101), 29 units (29%) provided just one tonometer head per practitioner, making adequate soak time between patients unlikely. Every unit replenished the disinfectant at least daily, deemed sufficient for most agents. However, hydrogen peroxide solutions should be replenished twice daily, which did not take place in nine units. This survey reveals disparity between current tonometer disinfection practice and published international recommendations, with some institutions using practices that may render patients susceptible to transmissible infection.
Convergence of pattern generator outputs on a common mechanism of diaphragm motor unit recruitment
Mantilla, Carlos B.; Seven, Yasin B.; Sieck, Gary C.
2014-01-01
Motor units are the final element of neuromotor control. In manner analogous to the organization of neuromotor control in other skeletal muscles, diaphragm motor units comprise phrenic motoneurons located in the cervical spinal cord that innervate the diaphragm muscle, the main inspiratory muscle in mammals. Diaphragm motor units play a primary role in sustaining ventilation, but are also active in other non-ventilatory behaviors, including coughing, sneezing, vomiting, defecation and parturition. Diaphragm muscle fibers comprise all fiber types. Thus, diaphragm motor units display substantial differences in contractile and fatigue properties, but importantly properties of the motoneuron and muscle fibers within a motor unit are matched. As in other skeletal muscles, diaphragm motor units are recruited in order such that motor units that display greater fatigue resistance are recruited earlier and more often than more fatigable motor units. The properties of the motor unit population are critical determinants of the function of a skeletal muscle across the range of possible motor tasks. Accordingly, fatigue-resistant motor units are sufficient to generate the forces necessary for ventilatory behaviors whereas more fatigable units are only activated during expulsive behaviors important for airway clearance. Neuromotor control of diaphragm motor units may reflect selective inputs from distinct pattern generators distributed according to the motor unit properties necessary to accomplish these different motor tasks. In contrast, widely-distributed inputs to phrenic motoneurons from various pattern generators (e.g., for breathing, coughing or vocalization) would dictate recruitment order based on intrinsic electrophysiological properties. PMID:24746055
Biomedical Communications Units and Their Parent Organizations: A Survey.
ERIC Educational Resources Information Center
Merrill, Irving R.
1978-01-01
Reports a survey of the 89 biomedical communications units in U.S. institutions offering baccalaureate or higher level programs in the health sciences. Findings are reported under these headings: unit assignment, perceived unit importance, centralization-decentralization, and unit mission. (VT)
7 CFR 1206.23 - United States.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 10 2011-01-01 2011-01-01 false United States. 1206.23 Section 1206.23 Agriculture... INFORMATION Mango Promotion, Research, and Information Order Definitions § 1206.23 United States. United... Rico, and the territories and possessions of the United States. ...
7 CFR 1206.23 - United States.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 10 2012-01-01 2012-01-01 false United States. 1206.23 Section 1206.23 Agriculture... INFORMATION Mango Promotion, Research, and Information Order Definitions § 1206.23 United States. United... Rico, and the territories and possessions of the United States. ...
7 CFR 1206.23 - United States.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 10 2013-01-01 2013-01-01 false United States. 1206.23 Section 1206.23 Agriculture... INFORMATION Mango Promotion, Research, and Information Order Definitions § 1206.23 United States. United... Rico, and the territories and possessions of the United States. ...
7 CFR 1206.23 - United States.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 10 2014-01-01 2014-01-01 false United States. 1206.23 Section 1206.23 Agriculture... INFORMATION Mango Promotion, Research, and Information Order Definitions § 1206.23 United States. United... Rico, and the territories and possessions of the United States. ...
43 CFR 3281.15 - What is the minimum initial unit obligation a unit agreement must contain?
Code of Federal Regulations, 2011 CFR
2011-10-01
... (3000) GEOTHERMAL RESOURCES UNIT AGREEMENTS Application, Review, and Approval of a Unit Agreement § 3281... drilling temperature gradient wells. (d) BLM will not consider any work done prior to unit approval for the...
Temperature rise induced by some light emitting diode and quartz-tungsten-halogen curing units.
Asmussen, Erik; Peutzfeldt, Anne
2005-02-01
Because of the risk of thermal damage to the pulp, the temperature rise induced by light-curing units should not be too high. LED (light emitting diode) curing units have the main part of their irradiation in the blue range and have been reported to generate less heat than QTH (quartz-tungsten-halogen) curing units. This study had two aims: first, to measure the temperature rise induced by ten LED and three QTH curing units; and, second, to relate the measured temperature rise to the power density of the curing units. The light-induced temperature rise was measured by means of a thermocouple embedded in a small cylinder of resin composite. The power density was measured by using a dental radiometer. For LED units, the temperature rise increased with increasing power density, in a statistically significant manner. Two of the three QTH curing units investigated resulted in a higher temperature rise than LED curing units of the same power density. Previous findings, that LED curing units induce less temperature rise than QTH units, does not hold true in general.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-20
...- 2010-0329] Braidwood Station, Units 1 and 2 and Byron Station, Unit Nos. 1 and 2; Notice of Withdrawal... NPF-77 for Braidwood Station, Units 1 and 2, respectively, located in Will County, Illinois, and to Facility Operating License Nos. NPF-37 and NPF-66 for Byron Station, Unit Nos. 1 and 2, respectively...
Metrication of clinical laboratory data in SI units.
Lehmann, H P
1976-01-01
The development and general concepts of the Système International d'Unités (SI units) are discussed. The basic and derived quantities and units of the SI used for clinical laboratory data are reviewed. Ranges of normal values for a number of body fluid constituents are given in the units in current general use and in SI units, with corresponding conversion factors.
U.S. Air Force Live | The Official Blog of the United States Air Force
. Christopher Uecker, 25th Aircraft Maintenance Unit weapons load crew team chief, tightens a guided bomb unit Uecker, 25th Aircraft Maintenance Unit weapons load crew team chief, tightens a guided bomb unit onto an Maintenance Unit load munitions onto an A-10 Thunderbolt II during the Vigilant Ace 16 exercise on Osan Air
ERIC Educational Resources Information Center
Hookham, Maurice; Holloway, Clive
Open University course units are presented on the philosophy of equality and inequality (Unit 3) and on personal inequality as an ideological concept (Unit 4). The substance of Unit 3 consists of extracts from the writings of eight philosophers. The role of the philosopher in forming legitimatizing ideologies is also illustrated. The eight…
The analysis of image motion by the rabbit retina
Oyster, C. W.
1968-01-01
1. Micro-electrode recordings were made from rabbit retinal ganglion cells or their axons. Of particular interest were direction-selective units; the common on—off type represented 20·6% of the total sample (762 units), and the on-type comprised 5% of the total. 2. From the large sample of direction-selective units, it was found that on—off units were maximally sensitive to only four directions of movement; these directions, in the visual field, were, roughly, anterior, superior, posterior and inferior. The on-type units were maximally sensitive to only three directions: anterior, superior and inferior. 3. The direction-selective unit's responses vary with stimulus velocity; both unit types are more sensitive to velocity change than to absolute speed. On—off units respond to movement at speeds from 6′/sec to 10°/sec; the on-type units responded as slowly as 30″/sec up to about 2°/sec. On-type units are clearly slow-movement detectors. 4. The distribution of direction-selective units depends on the retinal locality. On—off units are more common outside the `visual streak' (area centralis) than within it, while the reverse is true for the on-type units. 5. A stimulus configuration was found which would elicit responses from on-type units when the stimulus was moved in the null direction. This `paradoxical response' was shown to be associated with the silent receptive field surround. 6. The four preferred directions of the on—off units were shown to correspond to the directions of retinal image motion produced by contractions of the four rectus eye muscles. This fact, combined with data on velocity sensitivity and retinal distribution of on—off units, suggests that the on—off units are involved in control of reflex eye movements. 7. The on—off direction-selective units may provide error signals to a visual servo system which minimizes retinal image motion. This hypothesis agrees with the known characteristics of the rabbit's visual following reflexes, specifically, the slow phase of optokinetic nystagmus. PMID:5710424
Motor unit recruitment in human biceps brachii during sustained voluntary contractions.
Riley, Zachary A; Maerz, Adam H; Litsey, Jane C; Enoka, Roger M
2008-04-15
The purpose of the study was to examine the influence of the difference between the recruitment threshold of a motor unit and the target force of the sustained contraction on the discharge of the motor unit at recruitment. The discharge characteristics of 53 motor units in biceps brachii were recorded after being recruited during a sustained contraction. Some motor units (n = 22) discharged action potentials tonically after being recruited, whereas others (n = 31) discharged intermittent trains of action potentials. The two groups of motor units were distinguished by the difference between the recruitment threshold of the motor unit and the target force for the sustained contraction: tonic, 5.9 +/- 2.5%; intermittent, 10.7 +/- 2.9%. Discharge rate for the tonic units decreased progressively (13.9 +/- 2.7 to 11.7 +/- 2.6 pulses s(-1); P = 0.04) during the 99 +/- 111 s contraction. Train rate, train duration and average discharge rate for the intermittent motor units did not change across 211 +/- 153 s of intermittent discharge. The initial discharge rate at recruitment during the sustained contraction was lower for the intermittent motor units (11.0 +/- 3.3 pulses s(-1)) than the tonic motor units (13.7 +/- 3.3 pulses s(-1); P = 0.005), and the coefficient of variation for interspike interval was higher for the intermittent motor units (34.6 +/- 12.3%) than the tonic motor units (21.2 +/- 9.4%) at recruitment (P = 0.001) and remained elevated for discharge duration (34.6 +/- 9.2% versus 19.1 +/- 11.7%, P < 0.001). In an additional experiment, 12 motor units were recorded at two different target forces below recruitment threshold (5.7 +/- 1.9% and 10.5 +/- 2.4%). Each motor unit exhibited the two discharge patterns (tonic and intermittent) as observed for the 53 motor units. The results suggest that newly recruited motor units with recruitment thresholds closer to the target force experienced less synaptic noise at the time of recruitment that resulted in them discharging action potentials at more regular and greater rates than motor units with recruitment thresholds further from the target force.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Relations INTERNATIONAL BOUNDARY AND WATER COMMISSION, UNITED STATES AND MEXICO, UNITED STATES SECTION... and Mexico. (d) Commissioner means head of the United States Section, International Boundary and Water Commission, United States and Mexico. (e) Individual means a citizen of the United States or an alien...
22 CFR 1103.170 - Compliance procedures.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Foreign Relations INTERNATIONAL BOUNDARY AND WATER COMMISSION, UNITED STATES AND MEXICO, UNITED STATES... INTERNATIONAL BOUNDARY AND WATER COMMISSION, UNITED STATES AND MEXICO, UNITED STATES SECTION § 1103.170... Mexico, United States Section, The Commons, Building C, Suite 310, 4171 North Mesa, El Paso, Texas 79902...
Code of Federal Regulations, 2014 CFR
2014-04-01
... Relations INTERNATIONAL BOUNDARY AND WATER COMMISSION, UNITED STATES AND MEXICO, UNITED STATES SECTION... and Mexico. (d) Commissioner means head of the United States Section, International Boundary and Water Commission, United States and Mexico. (e) Individual means a citizen of the United States or an alien...
Code of Federal Regulations, 2011 CFR
2011-04-01
... Relations INTERNATIONAL BOUNDARY AND WATER COMMISSION, UNITED STATES AND MEXICO, UNITED STATES SECTION... and Mexico. (d) Commissioner means head of the United States Section, International Boundary and Water Commission, United States and Mexico. (e) Individual means a citizen of the United States or an alien...
Code of Federal Regulations, 2012 CFR
2012-04-01
... Relations INTERNATIONAL BOUNDARY AND WATER COMMISSION, UNITED STATES AND MEXICO, UNITED STATES SECTION... and Mexico. (d) Commissioner means head of the United States Section, International Boundary and Water Commission, United States and Mexico. (e) Individual means a citizen of the United States or an alien...
Harter, James K; Schmidt, Frank L; Hayes, Theodore L
2002-04-01
Based on 7,939 business units in 36 companies, this study used meta-analysis to examine the relationship at the business-unit level between employee satisfaction-engagement and the business-unit outcomes of customer satisfaction, productivity, profit, employee turnover, and accidents. Generalizable relationships large enough to have substantial practical value were found between unit-level employee satisfaction-engagement and these business-unit outcomes. One implication is that changes in management practices that increase employee satisfaction may increase business-unit outcomes, including profit.
Solar thermochemical processing system and method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wegeng, Robert S.; Humble, Paul H.; Krishnan, Shankar
A solar thermochemical processing system is disclosed. The system includes a first unit operation for receiving concentrated solar energy. Heat from the solar energy is used to drive the first unit operation. The first unit operation also receives a first set of reactants and produces a first set of products. A second unit operation receives the first set of products from the first unit operation and produces a second set of products. A third unit operation receives heat from the second unit operation to produce a portion of the first set of reactants.
Metal-air flow batteries using oxygen enriched electrolyte
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zheng, Jian-ping; Andrei, Petru; Shellikeri, Annadanesh
A metal air flow battery includes an electrochemical reaction unit and an oxygen exchange unit. The electrochemical reaction unit includes an anode electrode, a cathode electrode, and an ionic conductive membrane between the anode and the cathode, an anode electrolyte, and a cathode electrolyte. The oxygen exchange unit contacts the cathode electrolyte with oxygen separate from the electrochemical reaction unit. At least one pump is provided for pumping cathode electrolyte between the electrochemical reaction unit and the oxygen exchange unit. A method for producing an electrical current is also disclosed.
Metal-air flow batteries using oxygen enriched electrolyte
Zheng, Jian-ping; Andrei, Petru; Shellikeri, Annadanesh; Chen, Xujie
2017-08-01
A metal air flow battery includes an electrochemical reaction unit and an oxygen exchange unit. The electrochemical reaction unit includes an anode electrode, a cathode electrode, and an ionic conductive membrane between the anode and the cathode, an anode electrolyte, and a cathode electrolyte. The oxygen exchange unit contacts the cathode electrolyte with oxygen separate from the electrochemical reaction unit. At least one pump is provided for pumping cathode electrolyte between the electrochemical reaction unit and the oxygen exchange unit. A method for producing an electrical current is also disclosed.
Evaluation of nano-technology-modified zirconia oral implants: a study in rabbits.
Lee, Jaebum; Sieweke, Janet H; Rodriguez, Nancy A; Schüpbach, Peter; Lindström, Håkan; Susin, Cristiano; Wikesjö, Ulf M E
2009-07-01
The objective of this study was to screen candidate nano-technology-modified, micro-structured zirconia implant surfaces relative to local bone formation and osseointegration. Proprietary nano-technology surface-modified (calcium phosphate: CaP) micro-structured zirconia implants (A and C), control micro-structured zirconia implants (ZiUnite), and titanium porous oxide implants (TiUnite) were implanted into the femoral condyle in 40 adult male New Zealand White rabbits. Each animal received one implant in each hind leg; thus, 20 animals received A and C implants and 20 animals received ZiUnite and TiUnite implants in contralateral hind legs. Ten animals/group were euthanized at weeks 3 and 6 when biopsies of the implant sites were processed for histometric analysis using digital photomicrographs produced using backscatter scanning electron microscopy. The TiUnite surface demonstrated significantly greater bone-implant contact (BIC) (77.6+/-2.6%) compared with the A (64.6+/-3.6%) and C (62.2+/-3.1%) surfaces at 3 weeks (p<0.05). Numerical differences between ZiUnite (70.5+/-3.1%) and A and C surfaces did not reach statistical significance (p>0.05). Similarly, there were non-significant differences between the TiUnite and the ZiUnite surfaces (p>0.05). At 6 weeks, there were no significant differences in BIC between the TiUnite (67.1+/-4.2%), ZiUnite (69.7+/-5.7%), A (68.6+/-1.9%), and C (64.5+/-4.1%) surfaces (p>0.05). TiUnite and ZiUnite implant surfaces exhibit high levels of osseointegration that, in this model, confirm their advanced osteoconductive properties. Addition of CaP nano-technology to the ZiUnite surface does not enhance the already advanced osteoconductivity displayed by the TiUnite and ZiUnite implant surfaces.
Cramer, Emily
2016-01-01
Abstract Hospital performance reports often include rankings of unit pressure ulcer rates. Differentiating among units on the basis of quality requires reliable measurement. Our objectives were to describe and apply methods for assessing reliability of hospital‐acquired pressure ulcer rates and evaluate a standard signal‐noise reliability measure as an indicator of precision of differentiation among units. Quarterly pressure ulcer data from 8,199 critical care, step‐down, medical, surgical, and medical‐surgical nursing units from 1,299 US hospitals were analyzed. Using beta‐binomial models, we estimated between‐unit variability (signal) and within‐unit variability (noise) in annual unit pressure ulcer rates. Signal‐noise reliability was computed as the ratio of between‐unit variability to the total of between‐ and within‐unit variability. To assess precision of differentiation among units based on ranked pressure ulcer rates, we simulated data to estimate the probabilities of a unit's observed pressure ulcer rate rank in a given sample falling within five and ten percentiles of its true rank, and the probabilities of units with ulcer rates in the highest quartile and highest decile being identified as such. We assessed the signal‐noise measure as an indicator of differentiation precision by computing its correlations with these probabilities. Pressure ulcer rates based on a single year of quarterly or weekly prevalence surveys were too susceptible to noise to allow for precise differentiation among units, and signal‐noise reliability was a poor indicator of precision of differentiation. To ensure precise differentiation on the basis of true differences, alternative methods of assessing reliability should be applied to measures purported to differentiate among providers or units based on quality. © 2016 The Authors. Research in Nursing & Health published by Wiley Periodicals, Inc. PMID:27223598
Rogers, A.D.; Fergason, R.L.
2011-01-01
The compositional, thermophysical and geologic characteristics of surface units in Iapygia and Tyrrhena Terra (60??E-100??E, 0??-30??S) provide new insights into the compositional stratigraphy of the region. Intercrater plains are dominated by two surface units. The older unit (unit 1) is deficient in olivine and more degraded and likely consists of a mixture of impact, volcanic and sedimentary materials. The younger unit (unit 2) is enriched in olivine, exhibits a resistant morphology and higher thermal inertia, and likely represents volcanic infilling of plains. Units 1 and 2 bear a strong resemblance to those previously mapped in Mare Serpentis, a section of highlands crust located northwest of Hellas Basin. Thus, the two major intercrater plains units are even more widespread than previously thought and therefore likely constitute important components of Mars' highland stratigraphy. Many craters in the region contain high thermal inertia deposits (unit 3) that are compositionally identical to unit 2. These may have formed via volcanic infilling or may represent sedimentary materials that have been eroded from crater walls and lithified. Less common units include olivine and/or pyroxene-rich massifs and crater central peaks. These are primarily found within Hellas Basin rim units and may represent mantle materials brought toward the surface during the Hellas impact. Putative chloride deposits are primarily associated with olivine-deficient surfaces (unit 1) that may be heavily degraded occurrences of unit 2. The observations raise a variety of questions related to Martian crustal evolution and alteration that may have more widespread implications outside the study region. Copyright ?? 2011 by the American Geophysical Union.
Rogers, A. Deanne; Fergason, Robin L.
2011-01-01
The compositional, thermophysical and geologic characteristics of surface units in Iapygia and Tyrrhena Terra (60°E-100°E, 0°-30°S) provide new insights into the compositional stratigraphy of the region. Intercrater plains are dominated by two surface units. The older unit (unit 1) is deficient in olivine and more degraded and likely consists of a mixture of impact, volcanic and sedimentary materials. The younger unit (unit 2) is enriched in olivine, exhibits a resistant morphology and higher thermal inertia, and likely represents volcanic infilling of plains. Units 1 and 2 bear a strong resemblance to those previously mapped in Mare Serpentis, a section of highlands crust located northwest of Hellas Basin. Thus, the two major intercrater plains units are even more widespread than previously thought and therefore likely constitute important components of Mars' highland stratigraphy. Many craters in the region contain high thermal inertia deposits (unit 3) that are compositionally identical to unit 2. These may have formed via volcanic infilling or may represent sedimentary materials that have been eroded from crater walls and lithified. Less common units include olivine and/or pyroxene-rich massifs and crater central peaks. These are primarily found within Hellas Basin rim units and may represent mantle materials brought toward the surface during the Hellas impact. Putative chloride deposits are primarily associated with olivine-deficient surfaces (unit 1) that may be heavily degraded occurrences of unit 2. The observations raise a variety of questions related to Martian crustal evolution and alteration that may have more widespread implications outside the study region.
NASA Astrophysics Data System (ADS)
Georgiev, Neven; Froitzheim, Nikolaus; Cherneva, Zlatka; Frei, Dirk; Grozdev, Valentin; Jahn-Awe, Silke; Nagel, Thorsten J.
2016-10-01
The Rhodope Metamorphic Complex is a stack of allochthons assembled during obduction, subduction, and collision processes from Jurassic to Paleogene and overprinted by extensional detachment faults since Middle Eocene. In the study area, the following nappes occur in superposition (from base to top): an orthogneiss-dominated unit (Unit I), garnet-bearing schist with amphibolite and serpentinite lenses (Unit II), greenschist, phyllite, and calcschist with reported Jurassic microfossils (Unit III), and muscovite-rich orthogneiss (Unit IV). U-Pb dating of zircons from a K-feldspar augengneiss (Unit I) yielded a protolith age of ca. 300 Ma. Garnet-bearing metasediment from Unit II yielded an age spectrum with distinct populations between 310 and 250 Ma (detrital), ca. 150 Ma, and ca. 69 Ma (the last two of high-grade metamorphic origin). An orthogneiss from Unit IV yielded a wide spectrum of ages. The youngest population gives a concordia age of 581 ± 5 Ma, interpreted as the age of the granitic protolith. Unit I represents the Lower Allochthon (Byala Reka-Kechros Dome), Unit II the Upper Allochthon (Krumovitsa-Kimi Unit), Unit III the Uppermost Allochthon (Circum-Rhodope Belt), and Unit IV a still higher, far-travelled unit of unknown provenance. Telescoping of the entire Rhodope nappe stack to a thickness of only a few 100 m is due to Late Eocene north directed extensional shearing along the newly defined Kulidzhik Detachment which is part of a major detachment system along the northern border of the Rhodopes. Older top-to-the south mylonites in Unit I indicate that Tertiary extension evolved from asymmetric (top-to-the-south) to symmetric (top-to-the-south and top-to-the-north), bivergent unroofing.
Brunstein, Claudio; Zhang, Mei-Jie; Barker, Juliet; St. Martin, Andrew; Bashey, Asad; de Lima, Marcos; Dehn, Jason; Hematti, Peiman; Perales, Miguel-Angel; Rocha, Vanderson; Territo, Mary; Weisdorf, Daniel; Eapen, Mary
2017-01-01
The effects of inter-unit HLA-match on early outcomes with regards to double cord blood transplantation have not been established. Therefore, we studied the effect of inter-unit HLA-mismatching on the outcomes of 449 patients with acute leukemia after double cord blood transplantation. Patients were divided into two groups: one group that included transplantations with inter-unit mismatch at 2 or less HLA-loci (n=381) and the other group with inter-unit mismatch at 3 or 4 HLA-loci (n=68). HLA-match considered low resolution matching at HLA-A and -B loci and allele-level at HLA-DRB1, the accepted standard for selecting units for double cord blood transplants. Patients’, disease, and transplant characteristics were similar in the two groups. We observed no effect of the degree of inter-unit HLA-mismatch on neutrophil (Hazard Ratio 1.27, P=0.11) or platelet (Hazard Ratio 0.1.13, P=0.42) recovery, acute graft-versus-host disease (Hazard Ratio 1.17, P=0.36), treatment-related mortality (Hazard Ratio 0.92, P=0.75), relapse (Hazard Ratio 1.18, P=0.49), treatment failure (Hazard Ratio 0.99, P=0.98), or overall survival (Hazard Ratio 0.98, P=0.91). There were no differences in the proportion of transplants with engraftment of both units by three months (5% after transplantation of units with inter-unit mismatch at ≤2 HLA-loci and 4% after transplantation of units with inter-unit mismatch at 3 or 4 HLA-loci). Our observations support the elimination of inter-unit HLA-mismatch criterion when selecting cord blood units in favor of optimizing selection based on individual unit characteristics. PMID:28126967
Firing patterns of spontaneously active motor units in spinal cord-injured subjects
Zijdewind, Inge; Thomas, Christine K
2012-01-01
Involuntary motor unit activity at low rates is common in hand muscles paralysed by spinal cord injury. Our aim was to describe these patterns of motor unit behaviour in relation to motoneurone and motor unit properties. Intramuscular electromyographic activity (EMG), surface EMG and force were recorded for 30 min from thenar muscles of nine men with chronic cervical SCI. Motor units fired for sustained periods (>10 min) at regular (coefficient of variation ≤ 0.15, CV, n = 19 units) or irregular intervals (CV > 0.15, n = 14). Regularly firing units started and stopped firing independently suggesting that intrinsic motoneurone properties were important for recruitment and derecruitment. Recruitment (3.6 Hz, SD 1.2), maximal (10.2 Hz, SD 2.3, range: 7.5–15.4 Hz) and derecruitment frequencies were low (3.3 Hz, SD 1.6), as were firing rate increases after recruitment (∼20 intervals in 3 s). Once active, firing often covaried, promoting the idea that units received common inputs. Half of the regularly firing units showed a very slow decline (>40 s) in discharge before derecruitment and had interspike intervals longer than their estimated afterhyperpolarisation potential (AHP) duration (estimated by death rate and breakpoint analyses). The other units were derecruited more abruptly and had shorter estimated AHP durations. Overall, regularly firing units had longer estimated AHP durations and were weaker than irregularly firing units, suggesting they were lower threshold units. Sustained firing of units at regular rates may reflect activation of persistent inward currents, visible here in the absence of voluntary drive, whereas irregularly firing units may only respond to synaptic noise. PMID:22310313
Motor unit recruitment in human genioglossus muscle in response to hypercapnia.
Nicholas, Christian L; Bei, Bei; Worsnop, Christopher; Malhotra, Atul; Jordan, Amy S; Saboisky, Julian P; Chan, Julia K M; Duckworth, Ella; White, David P; Trinder, John
2010-11-01
single motor unit recordings of the genioglossus (GG) muscle indicate that GG motor units have a variety of discharge patterns, including units that have higher discharge rates during inspiration (inspiratory phasic and inspiratory tonic), or expiration (expiratory phasic and expiratory tonic), or do not modify their rate with respiration (tonic). Previous studies have shown that an increase in GG muscle activity is a consequence of increased activity in inspiratory units. However, there are differences between studies as to whether this increase is primarily due to recruitment of new motor units (motor unit recruitment) or to increased discharge rate of already active units (rate coding). Sleep-wake state studies in humans have suggested the former, while hypercapnia experiments in rats have suggested the latter. In this study, we investigated the effect of hypercapnia on GG motor unit activity in humans during wakefulness. sleep research laboratory. sixteen healthy men. each participant was administered at least 6 trials with P(et)CO(2) being elevated 8.4 (SD = 1.96) mm Hg over 2 min following a 30-s baseline. Subjects were instrumented for GG EMG and respiratory measurements with 4 fine wire electrodes inserted subcutaneously into the muscle. One hundred forty-one motor units were identified during the baseline: 47% were inspiratory modulated, 29% expiratory modulated, and 24% showed no respiratory related modulation. Sixty-two new units were recruited during hypercapnia. The distribution of recruited units was significantly different from the baseline distribution, with 84% being inspiratory modulated (P < 0.001). Neither units active during baseline, nor new units recruited during hypercapnia, increased their discharge rate as P(et)CO(2) increased (P > 0.05 for all comparisons). increased GG muscle activity in humans occurs because of recruitment of previously inactive inspiratory modulated units.
Patterns of antibacterials use in intensive care units.
Santos, Edilson Floriano Dos; Lauria-Pires, Liana
2010-06-01
To know and compare the patterns of antimicrobials use in intensive care units (ICUs) based on the Anatomical Therapeutic Chemical/Defined Daily Dose (ATC/DDD) system. a prospective cohort study was conducted in three medical-surgical intensive care units, two of them in public hospitals and one in a private hospital. Simple random, independent samples of patients admitted from 10/2004 to 09/2005 to the selected intensive care units were used. The antibiotics use was assessed using the ATC/DDD system. The amount of antibacterials used in each intensive care unit, in grams, was transformed in daily defined dose (DDD). The number of DDDs was divided by the number of patient-days, multiplied by one thousand, to obtain the average density of consumption (DC) per thousand patient-days (DDD1000). 1,728 patients-days and 2,918.6 DDDs were examined in the three intensive care units, corresponding to an average density of consumption of 1,689.0 DDD1000. The median number of DDDs of antibiotics use in the public hospitals intensive care units was significantly higher (p=0.002) versus the private hospitals intensive care unit. The consumption of antibiotics in the private hospitals intensive care unit (DC=2,191.7 DDD1000) was significantly higher (p<0.001) versus the intensive care units of public hospitals (1,499.5 DDD1000). The most used antibiotics groups in the three intensive care units were 3rd generation cephalosporins, penicillins/betalactamases inhibitors, carbapenems and fluorquinolones. The pattern of antibiotics use in the three examined intensive care units was not uniform. The private hospitals intensive care unit used a significantly larger amount versus the public hospitals intensive care units. Nevertheless, the most used antibiotics groups were similar in the three intensive care units.
The Past, Present and Future of Geodemographic Research in the United States and United Kingdom
Singleton, Alexander D.; Spielman, Seth E.
2014-01-01
This article presents an extensive comparative review of the emergence and application of geodemographics in both the United States and United Kingdom, situating them as an extension of earlier empirically driven models of urban socio-spatial structure. The empirical and theoretical basis for this generalization technique is also considered. Findings demonstrate critical differences in both the application and development of geodemographics between the United States and United Kingdom resulting from their diverging histories, variable data economies, and availability of academic or free classifications. Finally, current methodological research is reviewed, linking this discussion prospectively to the changing spatial data economy in both the United States and United Kingdom. PMID:25484455
Hamlet, Jason R [Albuquerque, NM; Robertson, Perry J [Albuquerque, NM; Pierson, Lyndon G [Albuquerque, NM; Olsberg, Ronald R [Albuquerque, NM
2012-02-28
A deflate decompressor includes at least one decompressor unit, a memory access controller, a feedback path, and an output buffer unit. The memory access controller is coupled to the decompressor unit via a data path and includes a data buffer to receive the data stream and temporarily buffer a first portion the data stream. The memory access controller transfers fixed length data units of the data stream from the data buffer to the decompressor unit with reference to a memory pointer pointing into the memory buffer. The feedback path couples the decompressor unit to the memory access controller to feed back decrement values to the memory access controller for updating the memory pointer. The decrement values each indicate a number of bits unused by the decompressor unit when decoding the fixed length data units. The output buffer unit buffers a second portion of the data stream after decompression.
Tephra Blanket Record of a Violent Strombolian Eruption, Sunset Crater, Arizona
NASA Astrophysics Data System (ADS)
Wagner, K. D.; Ort, M. H.
2015-12-01
New fieldwork provides a detailed description of the widespread tephra of the ~1085 CE Sunset Crater eruption in the San Francisco Volcanic Field, Arizona, and refines interpretation of the eruptive sequence. The basal fine-lapilli tephra-fall-units I-IV are considered in detail. Units I and II are massive, with Unit I composed of angular to spiny clasts and II composed of more equant, oxidized clasts. Units III and IV have inversely graded bases and massive tops and are composed of angular to spiny iridescent and mixed iridescent and oxidized angular clasts, respectively. Xenoliths are rare in all units (<0.1%): sedimentary xenoliths are consistent with the known shallow country rock (Moenkopi and Kaibab Fms); magmatic xenoliths are pumiceous rhyolite mingled with basalt. Unit II is less sideromelane rich (20%) than Units I, III, and IV (60-80%). Above these units are at least two more coarse tephra-fall units. Variably preserved ash and fine-lapilli laminae cap the tephra blanket. This deposit is highly susceptible to reworking, and likely experienced both syn- and post-eruptive aeolian redistribution. It appears as either well sorted, alternating planar-parallel beds of ash and fine lapilli with rare wavy beds, or as cross- or planar-bedded ash. The tephra blanket as a whole is stratigraphically underlain by a fissure-fed lava flow and lapilli-fall units are intercalated with two larger flows. Mean grain size is coarsest in Unit I but coarsens in Units II-IV. Units I, III, and IV are moderately to poorly sorted with no skew. Unit II is better sorted and more coarse-skewed. Units I and III are slightly more platykurtic than II and IV. Without considering possible spatial effects introduced by dispersion patterns, bootstrap ANOVA confidence intervals suggest at least Unit II sorting and skewness are from distinct populations. Isopachs indicate Units I and II were associated with a 10-km-long fissure source. After or during Unit II's deposition, activity localized to Sunset Crater. Units III and IV were emplaced with waxing to sustained activity, and followed by at least two more sustained episodes. Two lava flows began effusing from the cone during this period and remained active after explosive activity ceased. Primary tephra deposition ended with a period of small discrete explosions.
REACH. Electricity Units. Secondary.
ERIC Educational Resources Information Center
Smith, Gene; Sappe, Hoyt
As a part of the REACH (Refrigeration, Electro-Mechanical, Air-Conditioning, Heating) electromechanical cluster, this student manual contains individualized instructional units in the area of electricity. The instructional units focus on electricity fundamentals and electric motors. Each unit follows a typical format that includes a unit sheet,…