Lucey, C
2006-11-01
This article briefly recounts the 21st July 2005, Blood Products Advisory Committee (BPAC) meeting concerning recommendations for management of donors and units testing positive for hepatitis B virus (HBV) DNA. The author attended the meeting. The United States Food and Drug Administration (FDA) web site was used for meeting materials, and handouts were collected at the meeting to provide narrative information. Two European experts assisted with HBV subject matter. The proceedings of the advisory committee, the issue briefing materials, and testing algorithms are presented. BPAC voted concurrence with the FDA algorithm for Management of Donors and Units Testing Positive for Hepatitis B Virus DNA.
Alter, H J; Epstein, J S; Swenson, S G; VanRaden, M J; Ward, J W; Kaslow, R A; Menitove, J E; Klein, H G; Sandler, S G; Sayers, M H
1990-11-08
We performed a multicenter study in 1989 to determine whether screening whole-blood donors for human immunodeficiency virus type 1 (HIV-1) p24 antigen would improve transfusion safety by identifying carriers of the virus who are seronegative for HIV-1 antibody. More than 500,000 donations were tested at 13 U.S. blood centers with test kits from two manufacturers. Units found repeatedly reactive were retested in a central laboratory; if the results were positive, they were confirmed by a neutralization assay. A subgroup of units was also tested for HIV-1 by the polymerase chain reaction. Selected donors confirmed or not confirmed as having p24 antigen were contacted for follow-up interviews to identify risk factors and undergo retesting for HIV-1 markers. Positive tests for p24 antigen were confirmed by neutralization in five donors (0.001 percent of all donations tested), all of whom were also positive for HIV-1 antibody and HIV-1 by polymerase chain reaction. Three of the antigen-positive donors had other markers of infectious disease that would have resulted in the exclusion of their blood; two had risk factors for HIV-1 that should have led to self-exclusion. Of 220 blood units with repeatedly reactive p24 antigen whose presence could not be confirmed by neutralization (0.04 percent of the donations studied), none were positive for HIV-1 antibody, HIV-1 by polymerase chain reaction (120 units tested), or virus culture (76 units tested)--attesting to the specificity of confirmatory neutralization. The finding that no donation studied was positive for p24 antigen and negative for HIV-1 antibody suggests that screening donors for p24 antigen with tests of the current level of sensitivity would not add substantially to the safety of the U.S. blood supply.
DAT positivity in blood donors: a perplexing scenario.
Bedi, Ravneet Kaur; Mittal, Kshitija; Sood, Tanvi; Kumar, Rakesh; Praveen, Ajay S
2014-04-01
A blood request was received for 70 year male patient suffering from Chronic Obstructive Pulmonary Disease with anemia. One unit was found incompatible in AHG phase. Patient's antibody screen, indirect antiglobulin test (IAT), direct antiglobulin test (DAT) and auto control was negative. DAT of donor unit was positive with anti IgG gel card and negative with C3d reagent along with positive auto control. Donor was 30 year male with no history of blood transfusion and medication and had no evidence of hemolysis. Donors with positive DAT should be deferred, notified and referred to physician but further studies are required. Copyright © 2014 Elsevier Ltd. All rights reserved.
Tuberculosis Infection in Urban Adolescents: Results of a School-Based Testing Program.
ERIC Educational Resources Information Center
Barry, M. Anita; And Others
1990-01-01
Discusses a tuberculosis skin testing program introduced for seventh and tenth grade students in Boston (Massachusetts) public schools. Positivity rate was significantly higher in tenth grade students. Among those testing positive, the majority were born outside the United States. Results suggest that testing may identify a significant number of…
Algebraic criteria for positive realness relative to the unit circle.
NASA Technical Reports Server (NTRS)
Siljak, D. D.
1973-01-01
A definition is presented of the circle positive realness of real rational functions relative to the unit circle in the complex variable plane. The problem of testing this kind of positive reality is reduced to the algebraic problem of determining the distribution of zeros of a real polynomial with respect to and on the unit circle. Such reformulation of the problem avoids the search for explicit information about imaginary poles of rational functions. The stated algebraic problem is solved by applying the polynomial criteria of Marden (1966) and Jury (1964), and a completely recursive algorithm for circle positive realness is obtained.
Simon, Uwe K.; Gesslbauer, Lisa; Fink, Andreas
2016-01-01
Epilepsy is not a regular topic in many countries’ schools. Thus many people harbor misconceptions about people suffering from this disease. It was our aim to a) examine what grade ten students know and believe about epilepsy, and b) to develop and test a teaching unit to improve their knowledge and attitude. The test group comprised eight grade ten classes from six different Austrian high schools (54 girls and 51 boys aged 14–17), the control group (no intervention) five grade ten classes from the same schools (26 girls and 37 boys aged 14–17). The teaching unit consisted of three 45-min lessons using different methods and material. Changes in knowledge about and attitude towards epilepsy as a result of the intervention were psychometrically assessed in a pre-test intervention post-test design (along with a follow-up assessment two months after the intervention) by means of a questionnaire capturing different facets of epilepsy-related knowledge and attitude. Across all knowledge/attitude domains, students of the test group had a significantly improved knowledge about and a more positive attitude towards epilepsy and people suffering from it after the teaching unit. However, starting levels were different between the five knowledge/attitude domains tested. Medical background knowledge was lowest and consequently associated with the highest increase after the intervention. This study shows that epilepsy-related knowledge of many grade ten high school students is fragmentary and that some harbor beliefs and attitudes which require improvement. Our comprehensive but concise teaching unit significantly increased knowledge about epilepsy and positively influenced attitude towards individuals with epilepsy. Thus we recommend implementing this unit into regular school curricula. PMID:26919557
Travel-associated acquisition of hepatitis C virus infection in patients receiving haemodialysis.
Ghafur, Abdul; Raza, Muhammad; Labbett, Wendy; Chawla, Anuradha; Smith, Colette; Ngui, Siew Lin; Davenport, Andrew; Geretti, Anna Maria
2007-09-01
It has been proposed that hepatitis C virus (HCV)-infected patients with end-stage renal disease undergoing maintenance haemodialysis may lack HCV antibody (anti-HCV) despite chronic HCV viraemia. This carries important implications for the design of surveillance policies. To characterize the prevalence of antibody-negative/RNA-positive HCV infection, patients attending seven haemodialysis units underwent anti-HCV testing using a third-generation assay and HCV RNA testing using real-time PCR. At screening, anti-HCV prevalence was 12/360 (3.3%; 95% CI 1.7-5.8%); 7/12 (58.3%) anti-HCV positive samples were HCV RNA positive. Among anti-HCV-negative samples, 2/348 (0.6%; 95% CI 0.2-2.1%) tested HCV RNA positive (genotype 1a). Retrospective testing of stored sera dated the infections to a period of holiday in the Indian subcontinent. The two infections were unrelated by HCV-NS5B sequencing. Only one of the two newly infected persons showed raised transaminases. Both developed anti-HCV within 8-13 weeks of follow-up. Prospective surveillance of travellers to resource-limited countries returning to the units showed a HCV incidence of 4/153 travel episodes (2.6%; 95% CI 0.7-6.6%) among 131 persons (3.1%; 95% CI 0.8-7.6%). Among haemodialysis patients in the United Kingdom, antibody-negative/RNA-positive HCV status is associated with newly acquired infection, rather than lack of antibody responses in chronic HCV infection. There is a significant risk of HCV infection associated with travel to resource-limited countries. Given that transaminase levels may be normal, HCV RNA testing is recommended in patients re-entering a dialysis unit following haemodialysis in settings where suboptimal infection control policies pose a risk of exposure to blood-borne viruses.
Helbert, M.; Sargur, R.; Swallow, K.; Harper, N.; Garcez, T.; Savic, S.; Savic, L.; Eren, E.
2017-01-01
Summary We describe an observational survey of diagnostic pathways in 104 patients attending four specialist allergy clinics in the United Kingdom following perioperative hypersensitivity reactions to chlorhexidine reactions. The majority were life‐threatening. Men undergoing urological or cardiothoracic surgery predominated. Skin prick testing and specific immunoglobulin (sIg)E testing were the most common tests used for diagnosis. Fifty‐three per cent of diagnoses were made on the basis of a single positive test. Where multiple tests were performed the sensitivity of intradermal, basophil activation and skin prick testing was 68% (50–86%), 50% (10–90%) and 35% (17–55%), respectively. Seven per cent were negative on screening tests initially, and 12 cases were only positive for a single test despite multiple testing. Intradermal tests appeared most sensitive in this context. Additional sensitization to other substances used perioperatively, particularly neuromuscular blocking agents (NMBA), was found in 28 patients, emphasizing the need to test for possible allergy to all drugs to which the patient was exposed even where chlorhexidine is positive. PMID:28194756
Bacterial screening of apheresis platelets with a rapid test: a 113-month single center experience.
Ruby, Kristen N; Thomasson, Reggie R; Szczepiorkowski, Zbigniew M; Dunbar, Nancy M
2018-04-17
The 2016 Food and Drug Administration draft guidance describes the use of a rapid test (RT) to enhance platelet transfusion safety and availability. This study reports a 113-month experience of screening of apheresis platelets (APs) by RT. From July 2008 to October 2015, all APs underwent an RT on Day 4. Day 6 and 7 units were transfused with transfusion medicine physician approval. Any units remaining on Day 8 had a second RT performed. From November 2015 to November 2017, APs underwent an RT on Day 5 with a repeat RT on Days 6 and 7. During both periods, positive RTs underwent confirmatory testing with culture when repeat testing was positive. A total of 9009 APs underwent an RT on Day 4 or 5. Of these, 45 (0.5%) were RT positive, with no true positives. A total of 754 underwent a second RT on Day 8, with no positives. Since November 2015, 1152 platelets have undergone a second RT on Day 6; 391 have undergone a third RT on Day 7. Of these, five (0.4%) were RT positive on Day 6, with no true positives. There were no septic transfusion reactions identified by passive surveillance at our institution during either study period. To date, we have not detected any true positives after performing 11,306 tests on 9009 APs. A total of 1906 underwent testing twice, and 391 underwent testing three times. We did not identify any conversions from negative to positive on repeat testing. © 2018 AABB.
NASA Astrophysics Data System (ADS)
Opshaug, Guttorm Ringstad
There are times and places where conventional navigation systems, such as the Global Positioning System (GPS), are unavailable due to anything from temporary signal occultations to lack of navigation system infrastructure altogether. The goal of the Leapfrog Navigation System (LNS) is to provide localized positioning services for such cases. The concept behind leapfrog navigation is to advance a group of navigation units teamwise into an area of interest. In a practical 2-D case, leapfrogging assumes known initial positions of at least two currently stationary navigation units. Two or more mobile units can then start to advance into the area of interest. The positions of the mobiles are constantly being calculated based on cross-range distance measurements to the stationary units, as well as cross-ranges among the mobiles themselves. At some point the mobile units stop, and the stationary units are released to move. This second team of units (now mobile) can then overtake the first team (now stationary) and travel even further towards the common goal of the group. Since there always is one stationary team, the position of any unit can be referenced back to the initial positions. Thus, LNS provides absolute positioning. I developed navigation algorithms needed to solve leapfrog positions based on cross-range measurements. I used statistical tools to predict how position errors would grow as a function of navigation unit geometry, cross-range measurement accuracy and previous position errors. Using this knowledge I predicted that a 4-unit Leapfrog Navigation System using 100 m baselines and 200 m leap distances could travel almost 15 km before accumulating absolute position errors of 10 m (1sigma). Finally, I built a prototype leapfrog navigation system using 4 GPS transceiver ranging units. I placed the 4 units in the vertices a 10m x 10m square, and leapfrogged the group 20 meters forwards, and then back again (40 m total travel). Average horizontal RMS position errors never exceeded 16 cm during these field tests.
Collin, Gilles; Ichou, Houria; Charpentier, Charlotte; Bendhafer, Samia; Dumitrescu, Madalina; Allal, Lahcene; Cojocaru, Bogdan; Desfrère, Luc; Descamps, Diane; Mandelbrot, Laurent; Houhou-Fidouh, Nadhira
2017-01-01
Background To date, only influenza and RSV testing are recommended for respiratory viruses’ detection in paediatric units. In this study, we described, according to seasons, ages and clinical units, the results obtained in children (<15 years old) by multiplex-PCR (mPCR) tests allowing a quick and wide range detection of all respiratory viruses. These results were also compared with RSV specific detection. Methods All nasopharyngeal mPCR and RSV tests requested by clinicians in our French teaching hospitals group between 2011 and 2014 were retrospectively included. All repeated samples for the same children in the same month were discarded. Results Of the 381 mPCR tests (344 children) performed, 51.4% were positive. Positivity and viral co-infection rates were higher in the 6–36 months old strata (81% and 25%, p<0.0001 and p = 0.04, respectively). Viral distribution showed strong variations across ages. During specific influenza epidemic periods, only 1/39 (2.5%) mPCR tests were positive for influenza and 19/39 (48.7%) for other viruses. During specific RSV epidemic periods, only 8/46 (17.4%) mPCR tests were positive for RSV and 14/46 (30.4%) for other viruses. 477/1529 (31.2%) of RSV immunochromatography-tests were positive. Among the negatives immunochromatography-test also explored by mPCR, 28/62 (31%) were positive for other respiratory viruses. Conclusion This study provides a wide description of respiratory viruses’ distribution among children in hospital settings using mPCR over 3 years. It emphasizes the number of undiagnosed respiratory viruses according to the current diagnosis practice in France and gives a better picture of respiratory viruses identified in hospital settings by mPCR all over the year in France. PMID:28235002
Curtis-Robles, Rachel; Zecca, Italo B; Roman-Cruz, Valery; Carbajal, Ester S; Auckland, Lisa D; Flores, Isidore; Millard, Ann V; Hamer, Sarah A
2017-04-01
AbstractThe zoonotic, vector-borne parasite Trypanosoma cruzi causes Chagas disease throughout the Americas, but human and veterinary health burdens in the United States are unknown. We conducted a cross-sectional prevalence study in indigent, medically underserved human and cohabiting canine populations of seven south Texas border communities, known as colonias. Defining positivity as those samples that were positive on two or more independent tests, we found 1.3% seroprevalence in 233 humans, including one child born in the United States with only short-duration travel to Mexico. Additionally, a single child with no travel outside south Texas was positive on only a single test. Among 209 dogs, seroprevalence was 19.6%, but adjusted to 31.6% when including those dogs positive on only one test and extrapolating potential false negatives. Parasite DNA was detected in five dogs, indicating potential parasitemia. Seropositive dogs lived in all sampled colonias with no difference in odds of positivity across age, sex, or breed. Colonia residents collected two adult Triatoma gerstaeckeri and one nymph triatomine from around their homes; one of three bugs was infected with T. cruzi , and blood meal hosts were molecularly determined to include dog, human, and raccoon. Dogs and the infected vector all harbored T. cruzi discrete typing unit I, which has previously been implicated in human disease in the United States. Colonias harbor active T. cruzi transmission cycles and should be a priority in outreach and vector control initiatives.
ERIC Educational Resources Information Center
Holburn, C. Steven; Dougher, Michael J.
1985-01-01
Techniques for training a severely retarded blind client to exit his living unit during a fire drill used a combination of negative and positive reinforcement. Following a shaping procedure, the client learned to leave his living unit from any internal point through generalization training and subsequent test probes. (Author/CL)
Getting to Zero Yield: The Evolution of the U.S. Position on the CTBT
NASA Astrophysics Data System (ADS)
Zimmerman, Peter D.
1998-03-01
In 1994 the United States favored a Comprehensive Test Ban Treaty (CTBT) which permitted tiny "hydronuclear" experiments with a nuclear energy release of four pounds or less. Other nuclear powers supported yield limits as high as large fractions of a kiloton, while most non-nuclear nations participating in the discussions at the United Nations Conference on Disarmament wanted to prohibit all nuclear explosions -- some even favoring an end to computer simulations. On the other hand, China wished an exception to permit high yield "peaceful" nuclear explosions. For the United States to adopt a new position favoring a "true zero" several pieces had to fall into place: 1) The President had to be assured that the U.S. could preserve the safety and reliability of the enduring stockpile without yield testing; 2) the U.S. needed to be sure that the marginal utility of zero-yield experiments was at least as great for this country as for any other; 3) that tests with any nuclear yield might have more marginal utility for nuclear proliferators than for the United States, thus marginally eroding this country's position; 4) the United States required a treaty which would permit maintenance of the capacity to return to testing should a national emergency requiring a nuclear test arise; and 5) all of the five nuclear weapons states had to realize that only a true-zero CTBT would have the desired political effects. This paper will outline the physics near zero yield and show why President Clinton was persuaded by arguments from many viewpoints to endorse a true test ban in August, 1996 and to sign the CTBT in September, 1997.
Huang, David B; File, Thomas M; Dryden, Matthew; Corey, G Ralph; Torres, Antoni; Wilcox, Mark H
2018-04-01
Iclaprim is a diaminopyrimidine, which inhibits bacterial dihydrofolate reductase, and it is highly active against Gram-positive pathogens including emerging drug-resistant pathogens. In vitro activity of iclaprim and comparators against 2814 Gram-positive clinical isolates from the United States, Asia Pacific, Latin American and Europe collected between 2012 and 2014 were tested. Susceptibility testing was performed according to the Clinical and Laboratory Standards Institute (CLSI) guidelines. Minimum inhibitory concentration (MIC) interpretations were based on CLSI and European Committee on Antimicrobial Susceptibility Testing (EUCAST) criteria. MIC 50 /MIC 90 for all S. aureus, methicillin susceptible S. aureus, methicillin resistant S. aureus, beta-hemolytic streptococci, and Streptococcus pneumoniae were 0.06/0.12, 0.06/0.12, 0.06/0.5, 0.06/0.25, and 0.06/2μg/mL, respectively. Iclaprim was 8 to 32-fold more potent than trimethoprim, the only FDA approved dihydrofolate reductase inhibitor, against all Gram-positive isolates including resistant phenotypes. The MIC 90 of iclaprim was also lower than most of the comparators including linezolid and vancomycin against Gram-positive pathogens. Iclaprim demonstrated potent activity against a contemporary collection (2012-2014) of Gram-positive clinical isolates from the United States, Asia Pacific, Latin America and Europe. Copyright © 2017 Elsevier Inc. All rights reserved.
Clinical Utility of Fungal Screening Assays in Adults with Severe Burns
2013-01-01
available test, FungitellTM Glucan Assay for (1,3) b D glucan (BG) in serum (Associates of Cape Cod Inc., East Falmouth, MA), is a qualitative...considered a positive test in the United States and was used as a positive value in this study. A positive test is reported with a b D glucan concentration... Glucan as a diagnostic adjunct for invasive fungal infections: validation, cutoff development, and performance in patients with acute myelogenous
Cox, Louis Anthony; Popken, Douglas A; VanSickle, John J; Sahu, Ranajit
2005-08-01
The U.S. Department of Agriculture (USDA) tests a subset of cattle slaughtered in the United States for bovine spongiform encephalitis (BSE). Knowing the origin of cattle (U.S. vs. Canadian) at testing could enable new testing or surveillance policies based on the origin of cattle testing positive. For example, if a Canadian cow tests positive for BSE, while no U.S. origin cattle do, the United States could subject Canadian cattle to more stringent testing. This article illustrates the application of a value-of-information (VOI) framework to quantify and compare potential economic costs to the United States of implementing tracking cattle origins to the costs of not doing so. The potential economic value of information from a tracking program is estimated to exceed its costs by more than five-fold if such information can reduce future losses in export and domestic markets and reduce future testing costs required to reassure or win back customers. Sensitivity analyses indicate that this conclusion is somewhat robust to many technical, scientific, and market uncertainties, including the current prevalence of BSE in the United States and/or Canada and the likely reactions of consumers to possible future discoveries of BSE in the United States and/or Canada. Indeed, the potential value of tracking information is great enough to justify locating and tracking Canadian cattle already in the United States when this can be done for a reasonable cost. If aggressive tracking and testing can win back lost exports, then the VOI of a tracking program may increase to over half a billion dollars per year.
16 CFR 1203.1 - Scope, general requirements, and effective date.
Code of Federal Regulations, 2010 CFR
2010-01-01
... vision, positional stability, dynamic strength of retention system, and impact-attenuation tests described in §§ 1203.7 through 1203.17. (4) Units. The values stated in International System of Units (“SI...
Shin, Sue; Roh, Eun Youn; Oh, Sohee; Song, Eun Young; Kim, Eui Chong; Yoon, Jong Hyun
2017-01-01
Cord blood units (CBUs) for transplantation should be free of communicable disease and must contain a specific amount of total nucleated cells and CD34+ cells. Although posttransplantation cytomegalovirus (CMV) infections are from latent infection in patients, ensuring CMV-free CBUs by performing CMV-specific IgM and nucleic acid amplification testing (NAT) is one of the mandatory procedures for the safety of CBUs. However, the exclusion policies (based on these test results) vary among nations and institutions. We tested 28,000 processed CBUs between May 2006 and June 2014. The cord blood leukocytes from CMV IgM-positive samples were then subjected to NAT. The total nucleated cell and CD34+ cell counts were measured for each CBU, and the results were compared to the CMV IgM and IgG results. The seroprevalence of CMV among pregnant women was 98.1% (18,459/18,818) for IgG and 1.7% (441/25,293) for IgM. The concentration and the total number of CD34+ cells were significantly higher in CBUs from IgM-negative mothers compared to those from IgM-positive mothers (72.4/μl vs. 57.2/μl, respectively, p < 0.0001; 1.45 × 106/unit vs. 1.15 × 106/unit, respectively, p < 0.0001). Among CBUs with positive CMV IgM in their mothers' plasma or cord blood plasma, only 0.58% of the samples (3/517) had a positive NAT. The number of excluded CBUs from inventory due to positive CMV IgM in the cord blood was 54 of 18,326 (0.3%). For inventory purposes, it is appropriate to remove CBUs with positive cord blood CMV IgM findings irrespective of the NAT status as well as positive maternal CMV IgM in South Korea. PMID:27524276
Shin, Sue; Roh, Eun Youn; Oh, Sohee; Song, Eun Young; Kim, Eui Chong; Yoon, Jong Hyun
2017-01-24
Cord blood units (CBUs) for transplantation should be free of communicable disease and must contain a specific amount of total nucleated cells and CD34+ cells. Although posttransplantation cytomegalovirus (CMV) infections are from latent infection in patients, ensuring CMV-free CBUs by performing CMV-specific IgM and nucleic acid amplification testing (NAT) is one of the mandatory procedures for the safety of CBUs. However, the exclusion policies (based on these test results) vary among nations and institutions. We tested 28,000 processed CBUs between May 2006 and June 2014. The cord blood leukocytes from CMV IgM-positive samples were then subjected to NAT. The total nucleated cell and CD34+ cell counts were measured for each CBU, and the results were compared to the CMV IgM and IgG results. The seroprevalence of CMV among pregnant women was 98.1% (18,459/18,818) for IgG and 1.7% (441/25,293) for IgM. The concentration and the total number of CD34+ cells were significantly higher in CBUs from IgM-negative mothers compared to those from IgM-positive mothers (72.4/μl vs. 57.2/μl, respectively, p < 0.0001; 1.45 × 106/unit vs. 1.15 × 106/unit, respectively, p < 0.0001). Among CBUs with positive CMV IgM in their mothers' plasma or cord blood plasma, only 0.58% of the samples (3/517) had a positive NAT. The number of excluded CBUs from inventory due to positive CMV IgM in the cord blood was 54 of 18,326 (0.3%). For inventory purposes, it is appropriate to remove CBUs with positive cord blood CMV IgM findings irrespective of the NAT status as well as positive maternal CMV IgM in South Korea.
28 CFR 541.62 - Referral for placement.
Code of Federal Regulations, 2011 CFR
2011-07-01
... INMATE DISCIPLINE AND SPECIAL HOUSING UNITS Procedures for Handling of HIV Positive Inmates Who Pose... housing status when the inmate has been confirmed as testing HIV positive and when there is reliable...
28 CFR 541.62 - Referral for placement.
Code of Federal Regulations, 2013 CFR
2013-07-01
... INMATE DISCIPLINE AND SPECIAL HOUSING UNITS Procedures for Handling of HIV Positive Inmates Who Pose... housing status when the inmate has been confirmed as testing HIV positive and when there is reliable...
28 CFR 541.62 - Referral for placement.
Code of Federal Regulations, 2010 CFR
2010-07-01
... INMATE DISCIPLINE AND SPECIAL HOUSING UNITS Procedures for Handling of HIV Positive Inmates Who Pose... housing status when the inmate has been confirmed as testing HIV positive and when there is reliable...
28 CFR 541.62 - Referral for placement.
Code of Federal Regulations, 2014 CFR
2014-07-01
... INMATE DISCIPLINE AND SPECIAL HOUSING UNITS Procedures for Handling of HIV Positive Inmates Who Pose... housing status when the inmate has been confirmed as testing HIV positive and when there is reliable...
28 CFR 541.62 - Referral for placement.
Code of Federal Regulations, 2012 CFR
2012-07-01
... INMATE DISCIPLINE AND SPECIAL HOUSING UNITS Procedures for Handling of HIV Positive Inmates Who Pose... housing status when the inmate has been confirmed as testing HIV positive and when there is reliable...
Swivel arm perimeter for visual field testing in different body positions.
Flammer, J; Hendrickson, P; Lietz, A; Stümpfig, D
1993-01-01
To investigate the influence of body position on visual field results, a 'swivel arm perimeter' was built, based on a modified Octopus 1-2-3. Here, the measuring unit was detected from the control unit and mounted on a swivel arm, allowing its movement in all directions. The first results obtained with this device have indicated that its development was worthwhile.
28 CFR 541.60 - Purpose and scope.
Code of Federal Regulations, 2013 CFR
2013-07-01
... AND SPECIAL HOUSING UNITS Procedures for Handling of HIV Positive Inmates Who Pose Danger to Others... institutions, the Bureau of Prisons may place in controlled housing status an inmate who tests HIV positive...
28 CFR 541.60 - Purpose and scope.
Code of Federal Regulations, 2010 CFR
2010-07-01
... AND SPECIAL HOUSING UNITS Procedures for Handling of HIV Positive Inmates Who Pose Danger to Others... institutions, the Bureau of Prisons may place in controlled housing status an inmate who tests HIV positive...
28 CFR 541.60 - Purpose and scope.
Code of Federal Regulations, 2011 CFR
2011-07-01
... AND SPECIAL HOUSING UNITS Procedures for Handling of HIV Positive Inmates Who Pose Danger to Others... institutions, the Bureau of Prisons may place in controlled housing status an inmate who tests HIV positive...
28 CFR 541.60 - Purpose and scope.
Code of Federal Regulations, 2014 CFR
2014-07-01
... AND SPECIAL HOUSING UNITS Procedures for Handling of HIV Positive Inmates Who Pose Danger to Others... institutions, the Bureau of Prisons may place in controlled housing status an inmate who tests HIV positive...
28 CFR 541.60 - Purpose and scope.
Code of Federal Regulations, 2012 CFR
2012-07-01
... AND SPECIAL HOUSING UNITS Procedures for Handling of HIV Positive Inmates Who Pose Danger to Others... institutions, the Bureau of Prisons may place in controlled housing status an inmate who tests HIV positive...
Franson, J. Christian; Hofmeister, Erik K.; Collins, Gail H.; Dusek, Robert J.
2011-01-01
We screened 1,397 feral horses (Equus caballus) on Sheldon National Wildlife Refuge, Nevada, United States, for IgM and IgG against flavivirus during 2004–2006, 2008, and 2009. Positive serum samples were tested for neutralizing antibodies to West Nile virus (WNV) and St. Louis encephalitis virus (SLEV). One animal was positive for antibody against WNV in 2004, but all others tested in 2004–2006 were negative. In 2008 and 2009, we found evidence of increasing seropositive horses with age, whereas seroprevalence of WNV decreased from 19% in 2008 to 7.2% in 2009. No horses were positive for antibody against SLEV. Being unvaccinated, feral horses can be useful for WNV surveillance.
Eight-Year Review of Bordetella pertussis Testing Reveals Seasonal Pattern in the United States.
Bhatti, Micah M; Rucinski, Stefanea L; Schwab, Jeramy J; Cole, Nicolynn C; Gebrehiwot, Senait A; Patel, Robin
2017-03-01
Review of Bordetella pertussis polymerase chain reaction testing from 2007 through 2014 revealed a yearly spike in positivity rates during the summer throughout the United States. Paradoxically, the highest test volumes occurred outside of this time frame, which provides an opportunity for improved test utilization. © The Author 2015. Published by Oxford University Press on behalf of the Pediatric Infectious Diseases Society. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
2010-01-01
Background Occult hepatitis B virus (HBV) infection might transmit viremic units into the public blood supply if only hepatitis B surface antigen (HBsAg) testing is used for donor screening. Our aim was to evaluate the prevalence of occult HBV infection among the HBsAg negative/antiHBc positive donations from a highly HIV prevalent region of India. Methods A total of 729 HBsAg negative donor units were included in this study. Surface gene and precore region were amplified by in house nucleic acid test (NAT) for detection of occult HBV infection and surface gene was analyzed after direct sequencing. Results A total of 220 (30.1%) HBsAg negative donors were antiHBc positive, of them 66 (30%) were HBV DNA positive by NAT. HBV DNA positivity among 164 antiHBc only group, was 27.1% and among 40 antiHBs positive group was 30.0%. HBV/D (93.3%) was predominant and prevalence of both HBV/C and HBV/A was 3.3%. Single or multiple amino acids substitutions were found in 95% samples. Conclusion Thus, a considerable number of HBV infected donors remain undiagnosed, if only HBsAg is used for screening. Addition of antiHBc testing for donor screening, although will lead to rejection of a large number of donor units, will definitely eliminate HBV infected donations and help in reducing HBV transmission with its potential consequences, especially among the immunocompromised population. The HBV genetic diversity found in this donor population are in accordance with other parts of India. PMID:20799931
Panigrahi, Rajesh; Biswas, Avik; Datta, Sibnarayan; Banerjee, Arup; Chandra, Partha K; Mahapatra, Pradip K; Patnaik, Bharat; Chakrabarti, Sekhar; Chakravarty, Runu
2010-08-27
Occult hepatitis B virus (HBV) infection might transmit viremic units into the public blood supply if only hepatitis B surface antigen (HBsAg) testing is used for donor screening. Our aim was to evaluate the prevalence of occult HBV infection among the HBsAg negative/antiHBc positive donations from a highly HIV prevalent region of India. A total of 729 HBsAg negative donor units were included in this study. Surface gene and precore region were amplified by in house nucleic acid test (NAT) for detection of occult HBV infection and surface gene was analyzed after direct sequencing. A total of 220 (30.1%) HBsAg negative donors were antiHBc positive, of them 66 (30%) were HBV DNA positive by NAT. HBV DNA positivity among 164 antiHBc only group, was 27.1% and among 40 antiHBs positive group was 30.0%. HBV/D (93.3%) was predominant and prevalence of both HBV/C and HBV/A was 3.3%. Single or multiple amino acids substitutions were found in 95% samples. Thus, a considerable number of HBV infected donors remain undiagnosed, if only HBsAg is used for screening. Addition of antiHBc testing for donor screening, although will lead to rejection of a large number of donor units, will definitely eliminate HBV infected donations and help in reducing HBV transmission with its potential consequences, especially among the immunocompromised population. The HBV genetic diversity found in this donor population are in accordance with other parts of India.
ERIC Educational Resources Information Center
Marsiglia, Flavio F.; Williams, Lela Rankin; Ayers, Stephanie L.; Booth, Jaime M.
2014-01-01
Objectives: This article reports the effects of a culturally grounded parenting intervention to strengthen positive parenting practices. Method: The intervention was designed and tested with primarily Mexican origin parents in a large urban setting of the southwestern United States using an ecodevelopmental approach. Parents (N = 393) were…
Syphilis serology among transvestite prostitutes attending an HIV unit in Rome, Italy.
Gattari, P; Speziale, D; Grillo, R; Cattani, P; Zaccarelli, M; Spizzichino, L; Valenzi, C
1994-12-01
Sixty-seven transvestite prostitutes from Latin America (49 from Brazil and 18 from Colombia) who attended an HIV unit located in the inner city of Rome between January 1991 and June 1992 were studied for syphilis markers by means of both the Treponema pallidum haemoagglutination test (TPHA) and a solid phase haemadsorption test for detection of specific IgM (SPHA-IgM) which are typically present in recent infections. All participants reported more than 500 sexual partners in the past year, and 67.1% of them more than 1500 partners (between 5 and 10 partners per working day). The overall prevalence of anti-HIV antibodies in this population was 65.7%. The prevalence of positive TPHA tests in the population studied was 73.1%, while that of positive SPHA-IgM tests was 10.4%. The prevalence of positive TPHA and SPHA-IgM tests was higher among Columbians than among Brazilians (83.3% vs 69.4% and 22.2% vs 6.1%, respectively) and also showed a positive correlation with the duration of their permanence in Italy. The TPHA and SPHA-IgM positivities were significantly higher among subjects older than 29 years. Positive TPHA was also significantly higher in subjects who reported a history of heroin and/or cocaine abuse while positive SPHA-IgM was higher in subjects who did not use condoms or reported irregular use of them than in subjects who regularly used condoms. No overall correlation was evident between TPHA positivity and anti-HIV positivity, while SPHA-IgM positivity was found to be higher among anti-HIV-negative subjects.(ABSTRACT TRUNCATED AT 250 WORDS)
2014-01-01
Background The geographic distribution of canine infection with vector-borne disease agents in the United States appears to be expanding. Methods To provide an updated assessment of geographic trends in canine infection with Dirofilaria immitis, Borrelia burgdorferi, Ehrlichia spp., and Anaplasma spp., we evaluated results from an average of 3,588,477 dogs tested annually by veterinarians throughout the United States from 2010 – 2012. Results As in an earlier summary report, the percent positive test results varied by agent and region, with antigen of D. immitis and antibody to Ehrlichia spp. most commonly identified in the Southeast (2.9% and 3.2%, respectively) and antibody to both B. burgdorferi and Anaplasma spp. most commonly identified in the Northeast (13.3% and 7.1%, respectively) and upper Midwest (4.4% and 3.9%, respectively). Percent positive test results for D. immitis antigen were lower in every region considered, including in the Southeast, than previously reported. Percent positive test results for antibodies to B. burgdorferi and Ehrlichia spp. were higher nationally than previously reported, and, for antibodies to Anaplasma spp., were higher in the Northeast but lower in the Midwest and West, than in the initial report. Annual reports of human cases of Lyme disease, ehrlichiosis, and anaplasmosis were associated with percent positive canine test results by state for each respective tick-borne disease agent (R2 = 0.701, 0.457, and 0.314, respectively). Within endemic areas, percent positive test results for all three tick-borne agents demonstrated evidence of geographic expansion. Conclusions Continued national monitoring of canine test results for vector-borne zoonotic agents is an important tool for accurately mapping the geographic distribution of these agents, and greatly aids our understanding of the veterinary and public health threats they pose. PMID:24886589
Pathogen Reduction of Fresh Whole Blood for Military and Civilian Use
2010-04-01
NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR( S ) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME( S ) AND...MONITORING AGENCY NAME( S ) AND ADDRESS(ES) 10. SPONSOR/MONITOR’S ACRONYM( S ) 11. SPONSOR/MONITOR’S REPORT NUMBER( S ) 12. DISTRIBUTION/AVAILABILITY STATEMENT...treatment with 80 J/mLRBC in the Mirasol System. Strain of bacteria tested # of units positive/ # of units tested Serratia marcescens 0/3 Yersinia
Collins, Jeffrey M; Hunter, Mary; Gordon, Wanda; Kempker, Russell R; Blumberg, Henry M; Ray, Susan M
2018-06-01
Following large declines in tuberculosis transmission the United States, large-scale screening programs targeting low-risk healthcare workers are increasingly a source of false-positive results. We report a large cluster of presumed false-positive tuberculin skin test results in healthcare workers following a change to 50-dose vials of Tubersol tuberculin.Infect Control Hosp Epidemiol 2018;39:750-752.
Stored Canine Whole Blood Units: What is the Real Risk of Bacterial Contamination?
Miglio, A; Stefanetti, V; Antognoni, M T; Cappelli, K; Capomaccio, S; Coletti, M; Passamonti, F
2016-11-01
Bacterial contamination of whole blood (WB) units can result in transfusion-transmitted infection, but the extent of the risk has not been established and may be underestimated in veterinary medicine. To detect, quantify, and identify bacterial microorganisms in 49 canine WB units during their shelf life. Forty-nine healthy adult dogs. Forty-nine WB units were included in the study. Immediately after collection, 8 sterile samples from the tube segment line of each unit were aseptically collected and tested for bacterial contamination on days 0, 1, 7, 14, 21, 28, 35, and 42 of storage. A qPCR assay was performed on days 0, 21, and 35 to identify and quantify any bacterial DNA. On bacterial culture, 47/49 blood units were negative at all time points tested, 1 unit was positive for Enterococcus spp. on days 0 and 1, and 1 was positive for Escherichia coli on day 35. On qPCR assay, 26 of 49 blood units were positive on at least 1 time point and the bacterial loads of the sequences detected (Propionobacterium spp., Corynebacterium spp., Caulobacter spp., Pseudomonas spp., Enterococcus spp., Serratia spp., and Leucobacter spp.) were <80 genome equivalents (GE)/μL. Most of the organisms detected were common bacteria, not usually implicated in septic transfusion reactions. The very low number of GE detected constitutes an acceptable risk of bacterial contamination, indicating that WB units have a good sanitary shelf life during commercial storage. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
Seth, Puja; Walker, Tanja; Figueroa, Argelia
2017-07-01
In the United States, HIV infection disproportionately affects young gay, bisexual, and other men who have sex with men, aged 13-24 years (collectively referred to as YMSM), specifically black YMSM. Knowledge of HIV status is the first step for timely and essential prevention and treatment services. Because YMSM are disproportionately affected by HIV, the number of CDC-funded HIV testing events, overall and newly diagnosed HIV positivity, and linkage to HIV medical care among YMSM in non-health care settings were examined from 61 health department jurisdictions. Differences by age and race/ethnicity were analyzed. Additionally, trends in number of HIV testing events and newly diagnosed HIV positivity were examined from 2011 to 2015. In 2015, 42,184 testing events were conducted among YMSM in non-health care settings; this represents only 6% of tests in non-health care settings. Overall and newly diagnosed HIV positivity was 2.8% and 2.1%, respectively, with black/African-American YMSM being disproportionately affected (5.6% for overall; 4% for newly diagnosed); 71% of YMSM were linked within 90 days. The newly diagnosed HIV positivity among YMSM decreased from 2.8% in 2011 to 2.4% in 2015, and the number of newly diagnosed YMSM also decreased. Further targeted testing efforts among YMSM are needed to identify undiagnosed YMSM, specifically black YMSM.
ERIC Educational Resources Information Center
Sass, Daniel A.; Castro-Villarreal, Felicia; McWhirter, Benedict T.; McWhirter, Ellen Hawley; Karcher, Michael J.
2011-01-01
Positive associations between measures of school or academic connectedness and behavioral and academic outcomes suggest that connectedness is an important protective factor for adolescents in the United States. However, little is known about the meaning or measurement of academic connectedness, outside the United States, and especially in South…
Field tests of a handheld laser communications/position-finding binocular system
NASA Astrophysics Data System (ADS)
Chan, Victor J.; Rivers, Michael D.; Harris, Amy L.
1998-01-01
Lasers provide a means for transmitting larger quantities of data at higher rates than conventional radio frequency devices and can be utilized during radio silent operations on the battle field. A forward scout needs to be able to observe the positions of various targets and relay that information back to a tactical operations command center in a covert manner. The BiCom device built by Trex Communications provides laser ranging, azimuth and elevation angle to a target, GPS position information, data storage and transmit capability, and full duplex audio transmission capability, all in a 3 kg hand held package. The communication channel utilizes an eye safe lasercom transceiver for covert voice or data transfer at 100 kbps at distances of up to 5 km. The information gathered electronically by the unit is sufficient to calculate the actual GPS positions or military grid coordinates of the observed targets. Several dozen targets can be stored in memory for later transmission via lasercom. Field tests were conducted by US Army personnel to evaluate these units and compare the results with conventional means of target position determination and data transfer. A description of the system and results of these tests are presented.
Development of the fibre positioning unit of MOONS
NASA Astrophysics Data System (ADS)
Montgomery, David; Atkinson, David; Beard, Stephen; Cochrane, William; Drass, Holger; Guinouard, Isabelle; Lee, David; Taylor, William; Rees, Phil; Watson, Steve
2016-08-01
The Multi-Object Optical and Near-Infrared Spectrograph (MOONS) will exploit the full 500 square arcmin field of view offered by the Nasmyth focus of the Very Large Telescope and will be equipped with two identical triple arm cryogenic spectrographs covering the wavelength range 0.64μm-1.8μm, with a multiplex capability of over 1000 fibres. This can be configured to produce spectra for chosen targets and have close proximity sky subtraction if required. The system will have both a medium resolution (R 4000-6000) mode and a high resolution (R 20000) mode. The fibre positioning units are used to position each fibre independently in order to pick off each sub field of 1.0" within a circular patrol area of 85" on sky (50mm physical diameter). The nominal physical separation between FPUs is 25mm allowing a 100% overlap in coverage between adjacent units. The design of the fibre positioning units allows parallel and rapid reconfiguration between observations. The kinematic geometry is such that pupil alignment is maintained over the patrol area. This paper presents the design of the Fibre Positioning Units at the preliminary design review and the results of verification testing of the advanced prototypes.
Multichannel electrochemical microbial detection unit
NASA Technical Reports Server (NTRS)
Wilkins, J. R.; Young, R. N.; Boykin, E. H.
1978-01-01
The paper describes the design and capabilities of a compact multichannel electrochemical unit devised to detect and automatically indicate detection time length of bacteria. By connecting this unit to a strip-chart recorder, a permanent record is obtained of the end points and growth curves for each of eight channels. The experimental setup utilizing the multichannel unit consists of a test tube (25 by 150 mm) containing a combination redox electrode plus 18 ml of lauryl tryptose broth and positioned in a 35-C water bath. Leads from the electrodes are connected to the multichannel unit, which in turn is connected to a strip-chart recorder. After addition of 2.0 ml of inoculum to the test tubes, depression of the push-button starter activates the electronics, timer, and indicator light for each channel. The multichannel unit is employed to test tenfold dilutions of various members of the Enterobacteriaceae group, and a typical dose-response curve is presented.
Skin Testing With Water Buffalo's Milk in Children With Cow's Milk Allergy.
Sheehan, William J; Gardynski, Andrea; Phipatanakul, Wanda
2009-09-01
BACKGROUND: Cow's milk allergy is the most common food allergy in young children. In areas outside the United States, milk from other mammals has been studied as a possible and desirable alternative for children with cow's milk allergy. OBJECTIVES: We chose to further investigate water buffalo's milk as an alternative for cow's milk allergic children in the United States. METHODS: Children with cow's milk allergy were skin prick tested with water buffalo's milk. Additionally, subjects were followed clinically for 1 year after the test to determine how many of the subjects had persistent cow's milk allergy. RESULTS: In total, 30 children, age 8 months to 8 years, were skin prick tested to water buffalo's milk with 73% (22/30) having a positive test. All children with a negative water buffalo's milk skin test also had a negative cow's milk skin test. In follow-up, most (7 of 8) of the children with a negative skin prick test (SPT) to water buffalo's milk were found to have outgrown their cow's milk allergy. In comparison, all of the subjects with a positive skin test to water buffalo's milk had persistent cow's milk allergy. After adjusting for this, we determined that 96% (22/23) of the children with persistent cow's milk allergy were positive on skin testing to water buffalo's milk. CONCLUSIONS: In this population, the vast majority of children with persistent cow's milk allergy were positive on skin prick testing to water buffalo's milk. These results indicate that water buffalo's milk is unlikely to be a successful alternative for children with cow's milk allergy.
Autonomous microsystems for ground observation (AMIGO)
NASA Astrophysics Data System (ADS)
Laou, Philips
2005-05-01
This paper reports the development of a prototype autonomous surveillance microsystem AMIGO that can be used for remote surveillance. Each AMIGO unit is equipped with various sensors and electronics. These include passive infrared motion sensor, acoustic sensor, uncooled IR camera, electronic compass, global positioning system (GPS), and spread spectrum wireless transceiver. The AMIGO unit was configured to multipoint (AMIGO units) to point (base station) communication mode. In addition, field trials were conducted with AMIGO in various scenarios. These scenarios include personnel and vehicle intrusion detection (motion or sound) and target imaging; determination of target GPS position by triangulation; GPS position real time tracking; entrance event counting; indoor surveillance; and aerial surveillance on a radio controlled model plane. The architecture and test results of AMIGO will be presented.
Turbomachinery group for cold energy concept application
NASA Astrophysics Data System (ADS)
Alavi, S.; Arpi, A.; Ascani, M.; Cerri, G.; Chennaoui, L.; Manni, A.
2017-08-01
The paper discusses a special attempt to improve COP and compressor capacity. Theoretical and experimental results are presented, and they show a very positive trend. Compressor and Expander Group impellers are selected among the Car Engine Turbocharger Units. Modifications are proposed to achieve the best performance, taking the peculiar characteristics of the refrigerant into consideration. Tests have confirmed the positive saving trend, which can reach up to 22%-24% for an optimized bleed vapour generator and turbomachinery-based booster unit.
ERP correlates of source memory: unitized source information increases familiarity-based retrieval.
Diana, Rachel A; Van den Boom, Wijnand; Yonelinas, Andrew P; Ranganath, Charan
2011-01-07
Source memory tests typically require subjects to make decisions about the context in which an item was encoded and are thought to depend on recollection of details from the study episode. Although it is generally believed that familiarity does not contribute to source memory, recent behavioral studies have suggested that familiarity may also support source recognition when item and source information are integrated, or "unitized," during study (Diana, Yonelinas, and Ranganath, 2008). However, an alternative explanation of these behavioral findings is that unitization affects the manner in which recollection contributes to performance, rather than increasing familiarity-based source memory. To discriminate between these possibilities, we conducted an event-related potential (ERP) study testing the hypothesis that unitization increases the contribution of familiarity to source recognition. Participants studied associations between words and background colors using tasks that either encouraged or discouraged unitization. ERPs were recorded during a source memory test for background color. The results revealed two distinct neural correlates of source recognition: a frontally distributed positivity that was associated with familiarity-based source memory in the high-unitization condition only and a parietally distributed positivity that was associated with recollection-based source memory in both the high- and low-unitization conditions. The ERP and behavioral findings provide converging evidence for the idea that familiarity can contribute to source recognition, particularly when source information is encoded as an item detail. Copyright © 2010 Elsevier B.V. All rights reserved.
An extensible, low-cost drifter control unit
NASA Astrophysics Data System (ADS)
Giudici, Andrea; Torsvik, Tomas; Soomere, Tarmo
2017-04-01
We introduce an extensible, low-cost drifter control unit, which is developed for use with surface drifters that are deployed in inland water bodies or near-coast regions. The control unit is custom-built on top of a small footprint micro controller. It makes use of a GPS receiver for position tracking, a GSM radio for data transmission, and two sensor buses to handle analog and digital data measured by an array of external sensors. A cloud-based data collection platform receives and stores the data transmitted over GPRS from the drifter. The control unit was found to perform satisfactorily in operational testing, providing data at sub-Hz frequency for position and temperature during extended time. Test deployments revealed some issues related to power consumption spikes. Even though the unit is fully functional in the present form and shows, on average, low energy consumption , battery packs with relatively large maximum output power are required to ensure its operation within prolonged periods of time. We expect that a further development of the power supply unit together with a careful de-synchronization scheme of sensors' operation would smooth those peaks without any loss of the quality of recorded information.
O'Brien, D J; Fierke, J S; Cooley, T M; Fitzgerald, S D; Cosgrove, M K; Schmitt, S M
2013-11-01
Risks of bovine tuberculosis (bTB) transmission from free-ranging wildlife to livestock remain a concern in the United States, in both known endemic areas and where spillover from recently-infected livestock herds occurs. Federal agriculture officials in the United States (US) have recommended surveillance of non-cervid furbearers to determine whether free-ranging wildlife in the vicinity of cattle herd breakdowns are bTB infected, yet the efficacy of common diagnostic tests in these species is largely unknown. We calculated the sensitivity, specificity, predictive values and positive likelihood ratios for bTB infection in carcasses of sixteen species of furbearers tested via: (i) the presence of gross lesions compatible with bTB; (ii) histopathology consistent with bTB; and (iii) the presence of acid-fast bacilli (AFB) on histopathology. The gold standard comparison test was mycobacterial culture of cranial ± visceral lymph nodes pooled for each animal. Forty-two animals distributed across six species cultured bTB positive from among 1522 furbearers tested over thirteen years. The sensitivity of all three tests was poor (10%, 22% and 24% for gross lesions, AFB and histopathology, respectively), while specificities (all ≥ 99%) and negative predictive values (all ≥ 97%) were high. Positive predictive values varied widely (31-75%). Likelihood ratios for culture positivity given a positive test result showed AFB on histopathology to be the most reliable test, and gross lesions the least, though confidence intervals were wide and overlapping. While non-cervid furbearers may prove useful in North American bTB surveillance, wildlife managers should be aware of factors that may abate their utility and complicate interpretation of surveillance. © 2013 Blackwell Verlag GmbH.
Kumar, Mukesh; Ching, Lauren; Astern, Joshua; Lim, Eunjung; Stokes, Alexander J; Melish, Marian; Nerurkar, Vivek R
2016-12-01
Zika virus (ZIKV) is an emerging mosquito-borne pathogen. ZIKV infection is linked to the development of severe fetal abnormalities that include spontaneous abortion, stillbirth, hydranencephaly, and microcephaly. ZIKV outbreaks have been recorded in the United States. We recently demonstrated the first congenital ZIKV infection in the United States. In this study, we investigated archived blood samples from six mothers who gave birth to babies with microcephaly and 12 mothers who gave birth to healthy babies in Hawaii between 2009 and 2012. We tested maternal blood for the presence of ZIKV IgM and IgG antibodies using commercially available human ZIKV IgM and IgG ELISA kits. Blood from one mother who delivered babies with microcephaly tested positive for ZIKV IgM antibody (16.6%) and blood from three mothers tested positive for ZIKV IgG antibody (50%). ZIKV showed a trend toward significance with microcephaly. ZIKV IgG antibody positive mothers were more likely to deliver babies with microcephaly than mothers who were negative for ZIKV IgG antibodies (Odds ratio [OR] = 11.0, 95% confidence interval [CI] = 0.8-147.9, p = 0.083). Similarly, ZIKV IgM antibody positive mothers were also more likely to deliver babies with microcephaly than mothers who were negative for ZIKV IgM antibody (OR = 6.8, 95% CI = 0.2-195.1). These data provide further evidence of a link between ZIKV infection and microcephaly and suggests presence of ZIKV positive cases and associated microcephaly in the United States as early as 2009.
Development Specification for RV-346/348 Positive Pressure Relief Valves (PPRV)
NASA Technical Reports Server (NTRS)
Ralston, Russell L.
2017-01-01
This specification establishes the requirements for design, performance, safety, testing, and manufacture of the RV-346 and RV-348, Positive Pressure Relief Valve (PPRV) as part of the Advanced Extravehicular Mobility Unit (EMU)(AEMU) Portable Life Support System (PLSS). The RV-346 serves as the Positive Pressure Relief Valve (PPRV), and the RV-348 serves as the Secondary Positive Pressure Relief Valve (SPPRV).
Noh, Jaekwang; Ko, Hak Hyun; Yun, Yeomin; Choi, Young Sook; Lee, Sang Gon; Shin, Sue; Han, Kyou Sup; Song, Eun Young
2008-08-01
We evaluated the performance and false positive rate of Mediace RPR test (Sekisui, Japan), a newly introduced nontreponemal test using a chemistry autoanalyzer. The sensitivity of Mediace RPR test was analyzed using sera from 50 patients with syphilis in different stages (8 primary, 7 secondary, and 35 latent), 14 sera positive with fluorescent treponemal antibody absorption (FTA-ABS) IgM, and 74 sera positive with conventional rapid plasma regain (RPR) card test (Asan, Korea) and also positive with Treponema pallidum hemagglutination (TPHA) test or FTA-ABS IgG test. The specificity was analyzed on 108 healthy blood donors. We also performed RPR card test on 302 sera that had been tested positive with Mediace RPR test and also performed TPHA or FTA-ABS IgG test to analyze the false positive rate of Mediace RPR test. A cutoff value of 0.5 R.U. (RPR unit) was used for Mediace RPR test. Mediace RPR test on syphilitic sera of different stages (primary, secondary, and latent stages) and FTA-ABS IgM positive sera showed a sensitivity of 100%, 100%, 82.9% and 100%, respectively. Among the 74 sera positive with conventional RPR card test and TPHA or FTA-ABS IgG test, 55 were positive with Mediace test. The specificity of Mediace RPR test on blood donors was 97.2%. Among the 302 sera positive with Mediace RPR test, 137 sera (45.4%) were negative by RPR card and TPHA/FTA-ABS IgG tests. Although the sensitivities of Mediace RPR were good for primary and secondary syphilis, due to its high negative rate of Mediace RPR over the conventional RPR positive samples, further studies are necessary whether it can replace conventional nontreponemal test for screening purpose. Moreover, in view of the high false positive rate, positive results by Mediace RPR test should be confirmed with treponemal tests.
Berger, Michael; Gerganova, Veneta; Berger, Petya; Rapiteanu, Radu; Lisicovas, Viktoras; Dobrindt, Ulrich
2016-01-01
The extent to which chromosomal gene position in prokaryotes affects local gene expression remains an open question. Several studies have shown that chromosomal re-positioning of bacterial transcription units does not alter their expression pattern, except for a general decrease in gene expression levels from chromosomal origin to terminus proximal positions, which is believed to result from gene dosage effects. Surprisingly, the question as to whether this chromosomal context independence is a cis encoded property of a bacterial transcription unit, or if position independence is a property conferred by factors acting in trans, has not been addressed so far. For this purpose, we established a genetic test system assessing the chromosomal positioning effects by means of identical promoter-fluorescent reporter gene fusions inserted equidistantly from OriC into both chromosomal replichores of Escherichia coli K-12. Our investigations of the reporter activities in mutant cells lacking the conserved nucleoid associated protein HU uncovered various drastic chromosomal positional effects on gene transcription. In addition we present evidence that these positional effects are caused by transcriptional activity nearby the insertion site of our reporter modules. We therefore suggest that the nucleoid-associated protein HU is functionally insulating transcription units, most likely by constraining transcription induced DNA supercoiling. PMID:27545593
Simulation and ground testing with the Advanced Video Guidance Sensor
NASA Technical Reports Server (NTRS)
Howard, Richard T.; Johnston, Albert S.; Bryan, Thomas C.; Book, Michael L.
2005-01-01
The Advanced Video Guidance Sensor (AVGS), an active sensor system that provides near-range 6-degree-of-freedom sensor data, has been developed as part of an automatic rendezvous and docking system for the Demonstration of Autonomous Rendezvous Technology (DART). The sensor determines the relative positions and attitudes between the active sensor and the passive target at ranges up to 300 meters. The AVGS uses laser diodes to illuminate retro-reflectors in the target, a solid-state imager to detect the light returned from the target, and image capture electronics and a digital signal processor to convert the video information into the relative positions and attitudes. The development of the sensor, through initial prototypes, final prototypes, and three flight units, has required a great deal of testing at every phase, and the different types of testing, their effectiveness, and their results, are presented in this paper, focusing on the testing of the flight units. Testing has improved the sensor's performance.
Prototype design of singles processing unit for the small animal PET
NASA Astrophysics Data System (ADS)
Deng, P.; Zhao, L.; Lu, J.; Li, B.; Dong, R.; Liu, S.; An, Q.
2018-05-01
Position Emission Tomography (PET) is an advanced clinical diagnostic imaging technique for nuclear medicine. Small animal PET is increasingly used for studying the animal model of disease, new drugs and new therapies. A prototype of Singles Processing Unit (SPU) for a small animal PET system was designed to obtain the time, energy, and position information. The energy and position is actually calculated through high precison charge measurement, which is based on amplification, shaping, A/D conversion and area calculation in digital signal processing domian. Analysis and simulations were also conducted to optimize the key parameters in system design. Initial tests indicate that the charge and time precision is better than 3‰ FWHM and 350 ps FWHM respectively, while the position resolution is better than 3.5‰ FWHM. Commination tests of the SPU prototype with the PET detector indicate that the system time precision is better than 2.5 ns, while the flood map and energy spectra concored well with the expected.
Non-American SACEUR: Win-Win for NATO and the United States
2011-03-17
significant divides among NATO allies. Divisions between European members of the Alliance and the inherent schizophrenia caused by competing...The SACT position serves as a test case for the feasibility of a non-American SACEUR. 12 Prior to 2009, the United States also maintained a
"Living with Volcanoes": Cross-Curricular Teaching in the High School Classroom
ERIC Educational Resources Information Center
Jolley, Alison; Ayala, Gianna
2015-01-01
A new, interdisciplinary high school geoarchaeology curriculum unit, titled "Living with Volcanoes," was created and tested in two pilot lessons with 30 high school students total studying geography and classical civilization in northern England. Students were highly engaged during the curriculum unit and showed positive learning gains…
Mir, Nuria; Sánchez, Miguel; Baquero, Fernando; López, Blanca; Calderón, Celia; Cantón, Rafael
1998-01-01
The early detection of colonization with methicillin-resistant Staphylococcus aureus (MRSA) of patients in intensive-care units is an essential step in the strategy for preventing MRSA epidemics. In this study, tubes containing soft salt-mannitol agar with cloxacillin (6 μg/ml) (SSMAC) were prepared for inoculation of clinical samples at patients’ bedsides by personnel of an intensive-care unit. A total of 1,914 swabs from different sample sites of 81 patients were dipped into SSMAC tubes, and after 24 h of incubation (in an incubator located near the intensive-care unit), an evident color change was considered by the intensive-care-unit personnel to be an MRSA alarm. Sixty-three (3.3%) SSMAC tubes were considered positive for MRSA, 1,827 (95.4%) were considered negative, and 24 (1.2%) were considered intermediate. Compared with values for parallel conventional surveillance cultures for MRSA, excluding tubes with intermediate results, the SSMAC test had a sensitivity of 72.7%, a specificity of 99.2%, a positive predictive value of 76.2%, and a negative predictive value of 99.0%. When intermediate tubes were considered positive, the corresponding values were 75.3, 98.2, 63.2, and 99.0%, respectively. The sensitivity and specificity values of the test to identify MRSA-colonized patients were 89.4 and 100%, respectively. Oropharyngeal and naris specimens were the most reliable samples for MRSA detection. False-negative results were frequent in bronchial aspirates with low (<103 to 106 CFU/ml) MRSA counts. False-positive results were mainly due to methicillin-resistant Staphylococcus haemolyticus. The SSMAC tube is a useful, rapid, and inexpensive tool for the early identification of MRSA-colonized patients and, consequently, for the implementation of measures to prevent the spread of MRSA. PMID:9542922
Spot test kit for explosives detection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pagoria, Philip F; Whipple, Richard E; Nunes, Peter J
An explosion tester system comprising a body, a lateral flow membrane swab unit adapted to be removeably connected to the body, a first explosives detecting reagent, a first reagent holder and dispenser operatively connected to the body, the first reagent holder and dispenser containing the first explosives detecting reagent and positioned to deliver the first explosives detecting reagent to the lateral flow membrane swab unit when the lateral flow membrane swab unit is connected to the body, a second explosives detecting reagent, and a second reagent holder and dispenser operatively connected to the body, the second reagent holder and dispensermore » containing the second explosives detecting reagent and positioned to deliver the second explosives detecting reagent to the lateral flow membrane swab unit when the lateral flow membrane swab unit is connected to the body.« less
The Influence of Cardiac Risk Factor Burden on Cardiac Stress Test Outcomes.
Schrock, Jon W; Li, Morgan; Orazulike, Chidubem; Emerman, Charles L
2011-06-01
Chest pain is the most common admission diagnosis for observation unit patients. These patients often undergo cardiac stress testing to further risk stratify for coronary artery disease (CAD). The decision of whom to stress is currently based on clinical judgment. We sought to determine the influence of cardiac risk factor burden on cardiac stress test outcome for patients tested from an observation unit, inpatient or outpatient setting. We performed a retrospective observational cohort study for all patients undergoing stress testing in our institution from June 2006 through July 2007. Cardiac risk factors were collected at the time of stress testing. Risk factors were evaluated in a summative fashion using multivariate regression adjusting for age and known coronary artery disease. The model was tested for goodness of fit and collinearity and the c statistic was calculated using the receiver operating curve. A total of 4026 subjects were included for analysis of which 22% had known CAD. The rates of positive outcome were 89 (12.0%), 95 (12.6%), and 343 (16.9%) for the OU, outpatients, and hospitalized patients respectively. While the odds of a positive test outcome increased for additional cardiac risk factors, ROC curve analysis indicates that simply adding the number of risk factors does not add significant diagnostic value. Hospitalized patients were more likely to have a positive stress test, OR 1.41 (1.10 - 1.81). Our study does not support basing the decision to perform a stress test on the number of cardiac risk factors.
Cost implications of implementation of pathogen-inactivated platelets
McCullough, Jeffrey; Goldfinger, Dennis; Gorlin, Jed; Riley, William J; Sandhu, Harpreet; Stowell, Christopher; Ward, Dawn; Clay, Mary; Pulkrabek, Shelley; Chrebtow, Vera; Stassinopoulos, Adonis
2015-01-01
BACKGROUND Pathogen inactivation (PI) is a new approach to blood safety that may introduce additional costs. This study identifies costs that could be eliminated, thereby mitigating the financial impact. STUDY DESIGN AND METHODS Cost information was obtained from five institutions on tests and procedures (e.g., irradiation) currently performed, that could be eliminated. The impact of increased platelet (PLT) availability due to fewer testing losses, earlier entry into inventory, and fewer outdates with a 7-day shelf life were also estimated. Additional estimates include costs associated with managing 1) special requests and 2) test results, 3) quality control and proficiency testing, 4) equipment acquisition and maintenance, 5) replacement of units lost to positive tests, 6) seasonal or geographic testing, and 7) health department interactions. RESULTS All costs are mean values per apheresis PLT unit in USD ($/unit). The estimated test costs that could be eliminated are $71.76/unit and a decrease in transfusion reactions corresponds to $2.70/unit. Avoiding new tests (e.g., Babesia and dengue) amounts to $41.80/unit. Elimination of irradiation saves $8.50/unit, while decreased outdating with 7-day storage can be amortized to $16.89/unit. Total potential costs saved with PI is $141.65/unit. Costs are influenced by a variety of factors specific to institutions such as testing practices and the location in which such costs are incurred and careful analysis should be performed. Additional benefits, not quantified, include retention of some currently deferred donors and scheduling flexibility due to 7-day storage. CONCLUSIONS While PI implementation will result in additional costs, there are also potential offsetting cost reductions, especially after 7-day storage licensing. PMID:25989465
Cost implications of implementation of pathogen-inactivated platelets.
McCullough, Jeffrey; Goldfinger, Dennis; Gorlin, Jed; Riley, William J; Sandhu, Harpreet; Stowell, Christopher; Ward, Dawn; Clay, Mary; Pulkrabek, Shelley; Chrebtow, Vera; Stassinopoulos, Adonis
2015-10-01
Pathogen inactivation (PI) is a new approach to blood safety that may introduce additional costs. This study identifies costs that could be eliminated, thereby mitigating the financial impact. Cost information was obtained from five institutions on tests and procedures (e.g., irradiation) currently performed, that could be eliminated. The impact of increased platelet (PLT) availability due to fewer testing losses, earlier entry into inventory, and fewer outdates with a 7-day shelf life were also estimated. Additional estimates include costs associated with managing (1) special requests and (2) test results, (3) quality control and proficiency testing, (4) equipment acquisition and maintenance, (5) replacement of units lost to positive tests, (6) seasonal or geographic testing, and (7) health department interactions. All costs are mean values per apheresis PLT unit in USD ($/unit). The estimated test costs that could be eliminated are $71.76/unit and a decrease in transfusion reactions corresponds to $2.70/unit. Avoiding new tests (e.g., Babesia and dengue) amounts to $41.80/unit. Elimination of irradiation saves $8.50/unit, while decreased outdating with 7-day storage can be amortized to $16.89/unit. Total potential costs saved with PI is $141.65/unit. Costs are influenced by a variety of factors specific to institutions such as testing practices and the location in which such costs are incurred and careful analysis should be performed. Additional benefits, not quantified, include retention of some currently deferred donors and scheduling flexibility due to 7-day storage. While PI implementation will result in additional costs, there are also potential offsetting cost reductions, especially after 7-day storage licensing. © 2015 The Authors Transfusion published by Wiley Periodicals, Inc. on behalf of AABB.
Saini, Devashish; Mazza, Giovanni; Shah, Najaf; Mirza, Muzna; Gori, Mandar M; Nandigam, Hari Krishna; Orthner, Helmuth F
2006-01-01
Response times for pre-hospital emergency care may be improved with the use of algorithms that analyzes historical patterns in incident location and suggests optimal places for pre-positioning of emergency response units. We will develop such an algorithm based on cluster analysis and test whether it leads to significant improvement in mileage when compared to actual historical data of dispatching based on fixed stations.
West Nile virus among blood donors in the United States, 2003 and 2004.
Stramer, Susan L; Fang, Chyang T; Foster, Gregory A; Wagner, Annette G; Brodsky, Jaye P; Dodd, Roger Y
2005-08-04
West Nile virus first appeared in the United States in 1999 and has since spread throughout the contiguous states, resulting in thousands of cases of disease. By 2002, it was clear that the virus could be transmitted by blood transfusion, and by the middle of 2003, essentially all blood donations were being tested for West Nile virus RNA with the use of investigational nucleic acid amplification tests; testing was performed on individual samples or on "minipools" of up to 16 donations. We analyzed data from the West Nile virus testing program of the American Red Cross for 2003 and 2004 to identify geographic and temporal trends. In areas with a high incidence of infection, individual donations were tested to increase the sensitivity of testing. Donors with reactive results participated in follow-up studies to confirm the original reactivity and to assess the natural history of infection. Routine testing in 2003 and 2004 identified 540 donations that were positive for West Nile virus RNA, of which 362 (67 percent) were IgM-antibody-negative and most likely infectious. Of the 540 positive donations, 148 (27 percent) were detectable only by testing of individual donations, but only 15 of the 148 (10 percent) were negative for IgM antibody. The overall frequencies of RNA-positive donations during the epidemic periods were 1.49 per 10,000 donations in 2003 and 0.44 per 10,000 in 2004. In 2004, 52 percent of the positive donations were from donors in four counties in southern California. Rapid implementation of a nucleic acid amplification test led to the prospective identification of 519 donors who were positive for West Nile virus RNA and the removal of more than 1000 potentially infectious related components from the blood supply of the Red Cross. No cases of transfusion-transmitted infection were confirmed among recipients of the tested blood. Copyright 2005 Massachusetts Medical Society.
Larsen, C P; Ezligini, F; Hermansen, N O; Kjeldsen-Kragh, J
2005-02-01
Approximately 1 in every 2000 units of platelets is contaminated with bacteria. The BacT/ALERT automated blood culture system can be used to screen platelet concentrates (PCs) for bacterial contamination. Data were collected from May 1998 until May 2004. The number of PCs tested during this period was 36 896, most of which were produced from pools of four buffy-coats. On the day following blood collection or platelet apheresis, a 5-10 ml sample of the PC was aseptically transferred to a BacT/ALERT culture bottle for detection of aerobic bacteria. The sample was monitored for bacterial growth during the entire storage period of the PC (6.5 days). When a positive signal was generated, the culture bottle, the PC and the erythrocyte concentrates were tested for bacterial growth. In order to determine the frequency of false-negative BacT/ALERT signals, 1061 outdated PCs were tested during the period from May 2002 to May 2004. Eighty-eight positive signals were detected by the BacT/ALERT system, of which 12 were interpreted as truly positive. Fourteen signals were interpreted as truly false positive. Thirty-three signals were interpreted to be probably false positive. Two of 1061 outdated units tested positive, and Bacillus spp. and Staphylococcus epidermidis, respectively, were isolated from these PCs. Between 0.03% and 0.12% of the PCs were contaminated with bacteria. BacT/ALERT is an efficient tool for monitoring PCs for bacterial contamination; however, it is important to realize that false-negative results may occur.
Joshi, Manish; Monson, Thomas P; Woods, Gail L
2012-01-01
Interferon-gamma release assays including the QuantiFERON-TB Gold In-Tube test (QFT-GIT [Cellestis Ltd, Australia]) may be used in place of the tuberculin skin test (TST) in surveillance programs for Mycobacterium tuberculosis infection control. However, data on performance and practicality of the QFT-GIT in such programs for health care workers (HCWs) are limited. To assess the performance, practicality and reversion rate of the QFT-GIT among HCWs at a tertiary health care institution in the United States. Retrospective chart review of HCWs at Central Arkansas Veterans Healthcare System (Arkansas, USA) who underwent QFT-GIT testing as a part of their employee screening between November 1, 2008 and October 31, 2009. QFT-GIT was used to screen 3290 HCWs. The initial QFT-GIT was interpreted as positive for 129 (3.9%) HCWs, negative for 3155 (95.9%) and indeterminate for six (0.2%). Testing with QFT-GIT was repeated in 45 HCWs who had positive results on the initial test. The QFT-GIT reverted to negative in 18 (40.0%) HCWs, all of whom had negative TST status and initial interferon-gamma values of 0.35 IU⁄mL to 2.0 IU⁄mL. The QFT-GIT test is feasible in large health care setting as an alternative to TST for M tuberculosis infection screening in HCWs but is not free from challenges. The major concerns are the high number of positive test results and high reversion rates on repeat testing, illustrating poor short-term reproducibility of positive QFT-GIT test results. These results suggest adopting a borderline zone between interferon-gamma values of 0.35 IU⁄mL to 2.0 IU⁄mL, and cautious clinical interpretation of values in this range.
Challenges Women Face in Leadership Positions and Organizational Effectiveness: An Investigation
ERIC Educational Resources Information Center
Elmuti, Dean; Jia, Heather; Davis, Henry H.
2009-01-01
This study was undertaken to discover working public thoughts about roles of United States women in leadership positions and to test the relationship between managerial leadership styles and organizational effectiveness. A survey of perceptions of leadership roles and effectiveness distributed 700 randomly selected entities from industries in the…
Apheresis for Collection of Ebola Convalescent Plasma in Liberia
Brown, Jerry F.; Rowe, Kathleen; Zacharias, Peter; van Hasselt, James; Dye, John M.; Wohl, David A.; Fischer, William A.; Cunningham, Coleen K.; Thielman, Nathan M.; Hoover, David L.
2017-01-01
Purpose This report describes initiation of apheresis capability in Liberia, Africa to support a clinical trial of convalescent plasma therapy for Ebola Virus Disease. Methods A bloodmobile was outfitted in the United States as a four-bed apheresis unit with capabilities including pathogen reduction, electronic blood establishment computer system, designated areas for donor counseling and laboratory testing, and onboard electrical power generation. After air transport to Liberia, the bloodmobile was positioned at ELWA Hospital, Monrovia, and connected to the hospital’s power grid. Liberian staff were trained to conduct donor screening, which included questionnaire and onsite blood typing and transfusion transmitted infection (TTI) testing, and plasma collection and processing. Results The bloodmobile was operational within three weeks after arrival of the advance team. Of 101 donors who passed the pre-screening questionnaire, 32 were deferred. Twenty-eight of 99 tested survivors were deferred for positive transfusion transmitted infection (TTI) tests; 21 were positive for hepatitis B, hepatitis C, or human immunodeficiency virus. The majority of donors had type O blood; all but one were Rh positive. Forty-three survivors donated at least once; 89 apheresis attempts resulted in 81 successful collections. Conclusions Apheresis capability was emergently established in Liberia to support an efficacy trial of Ebola Convalescent Plasma. Extensive cooperation among multinational team members, engineers, logisticians and blood safety technical personnel at the operational site was required to surmount challenges to execution posed by logistical factors. The high proportion of positive TTI tests supported the use of a pathogen reduction system to enhance product safety. PMID:27393614
Maternal cfDNA screening for Down syndrome--a cost sensitivity analysis.
Cuckle, Howard; Benn, Peter; Pergament, Eugene
2013-07-01
This study aimed to determine the principal factors contributing to the cost of avoiding a birth with Down syndrome by using cell-free DNA (cfDNA) to replace conventional screening. A range of unit costs were assigned to each item in the screening process. Detection rates were estimated by meta-analysis and modeling. The marginal cost associated with the detection of additional cases using cfDNA was estimated from the difference in average costs divided by the difference in detection. The main factor was the unit cost of cfDNA testing. For example, replacing a combined test costing $150 with 3% false-positive rate and invasive testing at $1000, by cfDNA tests at $2000, $1500, $1000, and $500, the marginal cost is $8.0, $5.8, $3.6, and $1.4m, respectively. Costs were lower when replacing a quadruple test and higher for a 5% false-positive rate, but the relative importance of cfDNA unit cost was unchanged. A contingent policy whereby 10% to 20% women were selected for cfDNA testing by conventional screening was considerably more cost-efficient. Costs were sensitive to cfDNA uptake. Universal cfDNA screening for Down syndrome will only become affordable by public health purchasers if costs fall substantially. Until this happens, the contingent use of cfDNA is recommended. © 2013 John Wiley & Sons, Ltd.
Assessing Immunity to Rubella Virus: a Plea for Standardization of IgG (Immuno)assays
Bouthry, Elise; Huzly, Daniela; Ogee-Nwankwo, Adaeze; Hao, LiJuan; Adebayo, Adebola; Icenogle, Joseph; Sarasini, Antonella; Revello, Maria Grazia; Grangeot-Keros, Liliane
2016-01-01
Immunity to rubella virus (RV) is commonly determined by measuring specific immunoglobulin G (RV IgG). However, RV IgG results and their interpretation may vary, depending on the immunoassay, even though most commercial immunoassays (CIAs) have been calibrated against an international standard and results are reported in international units per milliliter. A panel of 322 sera collected from pregnant women that tested negative or equivocal for RV IgG in a prior test (routine screening) was selected. This panel was tested with two reference tests, immunoblotting (IB) and neutralization (Nt), and with 8 CIAs widely used in Europe. IB and Nt gave concordant results on 267/322 (82.9%) sera. Of these, 85 (26.4%) sera were negative and 182 (56.5%) sera were positive for both tests. All 85 IB/Nt-negative samples were classified as negative with all CIAs. Of the 182 IB/Nt-positive samples, 25.3 to 61.5% were classified as equivocal and 6 to 64.8% were classified as positive with the CIAs. Wide variations in titers in international units per milliliter were observed. In our series, more than half of the women considered susceptible to RV based on CIA results tested positive for RV antibodies by IB/Nt. Our data suggest that (i) sensitivity of CIAs could be increased by considering equivocal results as positive and (ii) the definition of immunity to RV as the 10-IU/ml usual cutoff as well as the use of quantitative results for clinical decisions may warrant reconsideration. A better standardization of CIAs for RV IgG determination is needed. PMID:27147722
Assessing Immunity to Rubella Virus: a Plea for Standardization of IgG (Immuno)assays.
Bouthry, Elise; Furione, Milena; Huzly, Daniela; Ogee-Nwankwo, Adaeze; Hao, LiJuan; Adebayo, Adebola; Icenogle, Joseph; Sarasini, Antonella; Revello, Maria Grazia; Grangeot-Keros, Liliane; Vauloup-Fellous, Christelle
2016-07-01
Immunity to rubella virus (RV) is commonly determined by measuring specific immunoglobulin G (RV IgG). However, RV IgG results and their interpretation may vary, depending on the immunoassay, even though most commercial immunoassays (CIAs) have been calibrated against an international standard and results are reported in international units per milliliter. A panel of 322 sera collected from pregnant women that tested negative or equivocal for RV IgG in a prior test (routine screening) was selected. This panel was tested with two reference tests, immunoblotting (IB) and neutralization (Nt), and with 8 CIAs widely used in Europe. IB and Nt gave concordant results on 267/322 (82.9%) sera. Of these, 85 (26.4%) sera were negative and 182 (56.5%) sera were positive for both tests. All 85 IB/Nt-negative samples were classified as negative with all CIAs. Of the 182 IB/Nt-positive samples, 25.3 to 61.5% were classified as equivocal and 6 to 64.8% were classified as positive with the CIAs. Wide variations in titers in international units per milliliter were observed. In our series, more than half of the women considered susceptible to RV based on CIA results tested positive for RV antibodies by IB/Nt. Our data suggest that (i) sensitivity of CIAs could be increased by considering equivocal results as positive and (ii) the definition of immunity to RV as the 10-IU/ml usual cutoff as well as the use of quantitative results for clinical decisions may warrant reconsideration. A better standardization of CIAs for RV IgG determination is needed. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Aragón-Sánchez, J; Lipsky, Benjamin A; Lázaro-Martínez, J L
2011-02-01
To investigate the accuracy of the sequential combination of the probe-to-bone test and plain X-rays for diagnosing osteomyelitis in the foot of patients with diabetes. We prospectively compiled data on a series of 338 patients with diabetes with 356 episodes of foot infection who were hospitalized in the Diabetic Foot Unit of La Paloma Hospital from 1 October 2002 to 31 April 2010. For each patient we did a probe-to-bone test at the time of the initial evaluation and then obtained plain X-rays of the involved foot. All patients with positive results on either the probe-to-bone test or plain X-ray underwent an appropriate surgical procedure, which included obtaining a bone specimen that was processed for histology and culture. We calculated the sensitivity, specificity, predictive values and likelihood ratios of the procedures, using the histopathological diagnosis of osteomyelitis as the criterion standard. Overall, 72.4% of patients had histologically proven osteomyelitis, 85.2% of whom had positive bone culture. The performance characteristics of both the probe-to-bone test and plain X-rays were excellent. The sequential diagnostic approach had a sensitivity of 0.97, specificity of 0.92, positive predictive value of 0.97, negative predictive value of 0.93, positive likelihood ratio of 12.8 and negative likelihood ratio of 0.02. Only 6.6% of patients with negative results on both diagnostic studies had osteomyelitis. Clinicians seeing patients in a setting similar to ours (specialized diabetic foot unit with a high prevalence of osteomyelitis) can confidently diagnose diabetic foot osteomyelitis when either the probe-to-bone test or a plain X-ray, or especially both, are positive. © 2011 The Authors. Diabetic Medicine © 2011 Diabetes UK.
Fitzgerald, F; Wing, K; Naveed, A; Gbessay, M; Ross, J C G; Checchi, F; Youkee, D; Jalloh, M B; Baion, D; Mustapha, A; Jah, H; Lako, S; Oza, S; Boufkhed, S; Feury, R; Bielicki, J; Williamson, E; Gibb, D M; Klein, N; Sahr, F; Yeung, S
2017-07-01
We collected data on 1054 children admitted to Ebola Holding Units in Sierra Leone and describe outcomes of 697/1054 children testing negative for Ebola virus disease (EVD) and accompanying caregivers. Case-fatality was 9%; 3/630 (0.5%) children discharged testing negative were readmitted EVD-positive. Nosocomial EVD transmission risk may be lower than feared. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.
Accuracy of BRT and Delvotest microbial inhibition tests as affected by composition of ewe's milk.
Althaus, Rafael; Torres, Antonio; Peris, Cristofol; Beltran, M Carmen; Fernandez, Nemesio; Molina, M Pilar
2003-03-01
The presence of drug residues in ewe's milk samples can be determined by microbial assays. The main limitation of these tests is the large number of false-positive results associated with them. False-positive results can be explained by the interaction of certain substances naturally existing in ewe's milk with the growth of the microorganism used in the test. In this study, milk chemical composition (fat, protein, lactose, total solids), somatic cell counts (SCCs), free fatty acid concentrations, and lactoperoxidase system components were determined in order to investigate their influence on the rate of false-positive results for the BRT and Delvotest microbiological inhibitor tests. Milk samples were obtained after morning milking of Manchega ewes at 15, 30, 45, 60, 75, 90, 105, 120, and 135 days after parturition. The animals did not receive any kind of treatment or medicated feed throughout the experiment. The false-positive rates for BRT and Delvotest were 3.75 and 2.4%, respectively. When the logistic regression model was applied, the percentages of total solids for positive samples were significantly different from those for negative samples (16.90 versus 18.42% for BRT, 16.05 versus 18.45% for Delvotest), while the SCC logarithmic transformation was significantly higher for the positive samples than for the negative samples (5.38 versus 5.11 log units for BRT, 5.32 versus 5.11 log units for Delvotest). Moreover, Delvotest-positive samples exhibited thiocyanate concentrations higher than those of Delvotest-negative samples (8.18 mg/liter versus 6.85 mg/liter). Further analyses are needed to confirm the possible presence of antimicrobial residues in this particular type of milk sample.
Bauermann, Fernando V; Flores, Eduardo F; Falkenberg, Shollie M; Weiblen, Rudi; Ridpath, Julia F
2014-01-01
The detection of an emerging pestivirus species, "HoBi-like virus," in fetal bovine serum (FBS) labeled as U.S. origin, but packaged in Europe, raised concerns that HoBi-like virus may have entered the United States. In the current study, 90 lots of FBS originating in North America (NA) were screened for pestivirus antigen and antibodies. Lots in group 1 (G1, 72 samples) and group 2 (G2, 9 samples) originated in NA and were packaged in the United States. Group 3 (G3) was composed of 9 lots collected in NA and processed in Europe. Lots in G1 were claimed negative for Bovine viral diarrhea virus (BVDV), while lots in G2 and G3 were claimed positive by the commercial processor. All lots in G1 and G2 tested negative by reverse transcription polymerase chain reaction (RT-PCR) using HoBi-like-specific primers. Two G1 lots tested positive by BVDV RT-PCR. One of these was also positive by virus isolation. All G2 lots were positive by BVDV RT-PCR. In addition, four G2 lots were VI positive while 1 lot was antigen-capture enzyme-linked immunosorbent assay (ELISA) positive. Two G3 lots were positive by HoBi-like-specific RT-PCR tests. All lots were negative for HoBi_D32/00 neutralizing antibodies. Seven lots (4 G1; 1 G2; 2 G3) had antibodies against BVDV by virus neutralization and/or antigen-capture ELISA. While there is no evidence of HoBi-like viruses in NA based on tested samples, further studies are required to validate HoBi-like virus-free status and develop means to prevent the spread of HoBi-like virus into NA.
Arkell, Paul; Youkee, Daniel; Brown, Colin S; Kamara, Abdul; Kamara, Thaim B; Johnson, Oliver; Lado, Marta; George, Viginia; Koroma, Fatmata; King, Matilda B; Parker, Benson E; Baker, Peter
2017-01-01
A central pillar in the response to the 2014 Ebola virus disease (EVD) epidemic in Sierra Leone was the role of Ebola Holding Units (EHUs). These units isolated patients meeting a suspect case definition, tested them for EVD, initiated appropriate early treatment and discharged negative patients to onward inpatient care or home. Positive patients were referred to Ebola Treatment Centres. We aimed to estimate the risk of nosocomial transmission within these EHUs. We followed up a cohort of 543 patients discharged with a negative EVD test from five EHUs in the Western Area, Sierra Leone, and examined all line-listed subsequent EVD tests from any facility in the Western Area to see whether the patient was retested within 30 days, matching by name, age and address. We defined possible readmissions as having the same name and age but uncertain address, and confirmed readmissions where name, age and address matched. We found a positive readmission rate of 3.3% (18 cases), which included 1.5% confirmed readmissions (8 cases) and 1.8% possible readmissions (10 cases). This is lower than rates previously reported. We cannot ascertain whether EVD was acquired within the EHUs or from re-exposure in the community. No demographic or clinical variables were identified as risk factors for positive readmission, likely due to our small sample size. These findings support the EHU model as a safe method for isolation of suspect EVD patients and their role in limiting the spread of EVD. © 2016 John Wiley & Sons Ltd.
Menor Almagro, Raúl; Rodríguez Gutiérrez, Juan Francisco; Martín-Martínez, María Auxiliadora; Rodríguez Valls, María José; Aranda Valera, Concepción; de la Iglesia Salgado, José Luís
To determine the dilution titles at antinuclear antibodies (ANA) by indirect immunofluorescence observed in cell substrate HEp-2 and its association with the diagnosis of systemic connective tissue disease in ANA test requested by a Rheumatology Unit. Samples of patients attended for the first time in the rheumatology unit, without prior ANA test, between January 2010 and December 2012 were selected. The dilution titers, immunofluorescence patterns and antigen specificity were recorded. In January 2015 the diagnosis of the patients were evaluated and classified in systemic disease connective tissue (systemic lupus erythematosus, Sjögren's syndrome, systemic sclerosis, undifferentiated connective, antiphospholipid syndrome, mixed connective tissue and inflammatory myophaty) or not systemic disease connective tissue. A total of 1282 ANA tests requested by the Rheumatology Unit in subjects without previous study, 293 were positive, predominance of women (81.9%). Patients with systemic connective tissue disease were recorded 105, and 188 without systemic connective tissue disease. For 1/640 dilutions the positive predictive value in the connective was 73.3% compared to 26.6% of non-connective, and for values ≥1/1,280 85% versus 15% respectively. When performing the multivariate analysis we observed a positive association between 1/320 dilution OR 3.069 (95% CI: 1.237-7.614; P=.016), 1/640 OR 12.570 (95% CI: 3.659-43.187; P=.000) and ≥1/1,280 OR 42.136 (95% CI: 8.604-206.345; P=.000). These results show association titles dilution ≥1/320 in ANA's first test requested by a Rheumatology Unit with patients with systemic connective tissue disease. The VPP in these patients was higher than previous studies requested by other medical specialties. This may indicate the importance of application of the test in a targeted way. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Reumatología y Colegio Mexicano de Reumatología. All rights reserved.
Qian, Jing; Wang, Bin; Han, Zhuo; Song, Baihe
2017-01-01
This research elucidates the role of ethical leadership in employee feedback seeking by examining how and when ethical leadership may exert a positive influence on feedback seeking. Using matched reports from 64 supervisors and 265 of their immediate employees from a hotel group located in a major city in China, we proposed and tested a moderated mediation model that examines leader-member exchange (LMX) as the mediator and emotional intelligence as well as work-unit structure as double moderators in the relationships between ethical leadership and followers' feedback-seeking behavior from supervisors and coworkers. Our findings indicated that (1) LMX mediated the positive relationship between ethical leadership and feedback seeking from both ethical leaders and coworkers, and (2) emotional intelligence and work-unit structure served as joint moderators on the mediated positive relationship in such a way that the relationship was strongest when the emotional intelligence was high and work-unit structure was more of an organic structure rather than a mechanistic structure.
Sporicidal activity of a new low-temperature sterilization technology: the Sterrad 50 sterilizer.
Rutala, W A; Gergen, M F; Weber, D J
1999-07-01
This study was undertaken to evaluate the efficacy of a new low-temperature sterilization system that recently has been cleared by the Food and Drug Administration, the Sterrad 50. Flat stainless steel carriers were inoculated with approximately 10(6) Bacillus stearothermophilus spores. These carriers were placed aseptically in the middle of 40-cm-long stainless steel-lumened test units of varying diameters (1 mm, 2 mm, and 3 mm). After inoculation, the test units were processed in the Sterrad 50. After sterilization, the carriers were assayed for growth of the B. stearothermophilus spores. Our data demonstrated that the Sterrad 50 was highly effective in killing the B. stearothermophilus spores (no positive carriers with 30 tests of each lumen-diameter test unit). The Sterrad 50 is likely to be clinically useful for the sterilization of heat-sensitive medical equipment.
PUBLIC HEALTH ASPECTS OF LYMPHOGRANULOMA VENEREUM
Koch, Richard A.; McDonald, Ruth S.; Marshall, Max S.
1949-01-01
The clinical symptoms of lymphogranuloma venereum with the serious pathologic changes often occurring in the late stages of the disease warrant greater attention to the disease. The reported ratio of cases of lymphogranuloma venereum to cases of syphilis and gonorrhea is much higher in San Francisco than in other metropolitan ports of western United States, apparently because of greater use of diagnostic tests for the disease. Tests of persons likely to be exposed and other persons not likely to be exposed to venereal diseases indicate that a positive reaction to a Frei test implies past or present infection with lymphogranuloma venereum. Positive reactions to complement fixation tests are notably more frequent than positive response to Frei tests. The complement fixation test appears to be an unreliable diagnostic aid. The frequency of positive reactions associated with other venereal diseases, and their infrequency otherwise, suggests that lymphogranuloma venereum may exist, unrecognized, in many persons, who may be, potentially at least, carriers of the disease. PMID:18147525
Tensile testing of thin-film microstructures
NASA Astrophysics Data System (ADS)
Greek, Staffan; Johansson, Stefan A. I.
1997-09-01
The mechanical properties of thin film microstructures depend on size and shape and on the film manufacturing process. Hence, the test structures that are used to measure mechanical properties should have dimensions of the same order of magnitude as an application structure. The microstructures are easily monitored in a scanning electron microscope (SEM), but to be handled and tested in situ a micromanipulator was developed. The parts of the micromanipulator essential to the tests are two independently moveable tables driven by electric motors. The test structures and a testing unit are mounted on the tables. A testing unit was designed to measure force and displacement with high resolution. The testing unit consists of an arm actuated by a piezoelectric element and equipped with a probe. An optical encoder measures the movement of the arm, while strain gauges measure the force in the arm. Test structures consist typically of a released beam fixed at one end with a ring at the other. The micromanipulator is used to position the probe of the testing unit in the ring. The testing unit then executed a tensile test of the beam. Test structures of polysilicon films produced under various process conditions were used to verify the possibility of measuring Young's modulus with an accuracy of +/- 5 percent, as well as fracture strength.Young's modulus is calculated using the difference in elongation for different beam lengths. The fracture strength of the beams was evaluated with Weibull statistics.
Song, Sharon; Johnson, Matthew; Harris, Aaron M.; Kaufman, Gary I.; Freedman, David; Quinn, Michael T.; Kim, Karen E.
2016-01-01
Introduction Most research on hepatitis B virus (HBV) infection in the United States is limited to Asian populations, despite an equally high prevalence among African immigrants. The purpose of this study was to determine testing and detection rates of HBV infection among African-born people residing in the Chicago metropolitan area. Methods A hepatitis education and prevention program was developed in collaboration with academic, clinical, and community partners for immigrant and refugee populations at risk for HBV infection. Community health workers implemented chain referral sampling, a novel strategy for recruiting hard-to-reach participants, targeting African-born participants. Participants were tested in both clinical and nonclinical settings. To assess infection status, blood samples were obtained for hepatitis B surface antigen (HBsAg), core antibody, and surface antibody testing. Demographic information was collected on age, sex, health insurance status, country of origin, and years residing in the United States. Participants were notified of testing results, and HBsAg-positive participants were referred for follow-up medical care. Results Of 1,000 African-born people who received education, 445 (45%) agreed to participate in HBV screening. There were 386 (87%) participants tested in clinical and 59 (13%) tested in nonclinical sites. Compared with participants who were tested in clinical settings, participants tested in nonclinical settings were older, were less likely to have health insurance, and had lived in the United States longer (P < .005 for each). Of these, most were from the Democratic Republic of the Congo (14%), Nigeria (13%), Ghana (11%), Somalia (11%), or Ethiopia (10%). There were 35 (8%) HBsAg-positive people, 37% had evidence of past infection, and 29% were immune. Conclusions Chain referral sampling identified many at-risk African-born people with chronic HBV infection. The large proportion of HBsAg-positive people in this sample reinforces the need for health promotion programs that are culturally appropriate and community-driven. PMID:27584874
[Silent myocardial ischemia in patients with transient ischemic attacks].
Sánchez Valiente, S; Mostacero, E; del Río, A; Morales, F
1994-10-01
Given evidence that ischemic heart disease is the most frequent cause of death in patients with cerebrovascular disease, we used ergometrics to screen 80 patients with TIA for silent myocardial ischemia (SMI) at the neurological unit of Hospital Clínico Universitario in Zaragoza, Spain. The patients were compared with a control group of 80 with no signs of heart disease. Neither the patients nor the controls had ever shown clinical signs of coronary ischemia and their baseline electrocardiograms were normal. Stress test results were positive in 25 (31%) of the TIA patients, and in 4 (5%) (p < 0.001) of the controls, showing that the prevalence of SMI is significantly higher in TIA patients than in the general population. Hiperlipidemia (75% testing positive versus 43% negative, p < 0.01) and diabetes (31% testing positive versus 13% negative, p < 0.01) were the risk factors statistically related with a positive stress test.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, H.; Higuchi, T.; Nishioki, N.
1997-01-01
A dual tunneling-unit scanning tunneling microscope (DTU STM) was developed for nm order length measurement with wide scan range. The crystalline lattice of highly oriented pyrolitic graphite (HOPG) was used as reference scale. A reference unit was set up on top of a test unit. The reference sample holder and the probe tip of test unit were attached to one single XY scanner on either surface, while the test sample holder was open. This enables simultaneous acquisition of wide images of HOPG and test sample. The length in test sample image was measured by counting the number of HOPG lattices.more » An inchworm actuator and an impact drive mechanism were introduced to roughly position probe tips. The XY scanner was designed to be elastic to eliminate image distortion. Some comparison experiments using two HOPG chips were carried out in air. The DTU STM is confirmed to be a stable and more powerful device for length measurement which has nanometer accuracy when covering a wide scan range up to several micrometers, and is capable of measuring comparatively large and heavy samples. {copyright} {ital 1997 American Vacuum Society.}« less
Opekun, Antone R; Luu, Phong; Gotschall, Ann B; Abdalla, Nageeb; Torres, Elizabeth; Rudd, Summer B; Graham, David Y; Nurgalieva, Zhannat Z; Tsuchiya, Kyoko
2006-07-01
A need exists for accurate point-of-care tests for diagnosis of Helicobacter pylori (H. pylori) infection to evaluate a rapid urine-H. pylori antibody test device for detection of H. pylori infection in a point-of-care setting in the United States. A multi-center study in a multi-ethnic population compared the RAPIRUN urine antibody test with the (13)C-urea breath test (C-UBT) and a traditional serologic test, the high-molecular-weight cell-associated protein enzyme immunoassay (HM-CAP EIA). The primary comparator was with "definite positive" and "definite negative" patients defined as a concordance of combined results of the UBT and the HM-CAP IgG EIA. Overall, 188 eligible patients were enrolled (61 men, age range: 18-73 years, including 84 Hispanics, 73 Asian-Pacific Americans, 22 Black African-Americans, 6 non-Hispanic Caucasians, and 3 of "other" ethnicity). Compared with "definite positive" and "definite negative" results, the sensitivity and specificity of the urine antibody test were 0.9 and 1.0, respectively. The urine antibody test proved suitable for point-of-care rapid diagnosis of anti-H. pylori antibodies indicative of active or past H. pylori infection.
Asymptomatic Lymphogranuloma Venereum in Men who Have Sex with Men, United Kingdom.
Saxon, Cara; Hughes, Gwenda; Ison, Catherine
2016-01-01
We investigated prevalence of lymphogranuloma venereum (LGV) among men who have sex with men who were tested for chlamydia at 12 clinics in the United Kingdom during 10 weeks in 2012. Of 713 men positive for Chlamydia trachomatis, 66 (9%) had LGV serovars; 15 (27%) of 55 for whom data were available were asymptomatic.
Effectiveness of Wellness-Based Classroom Guidance in Elementary School Settings: A Pilot Study
ERIC Educational Resources Information Center
Villalba, Jose A.; Myers, Jane E.
2008-01-01
A three-session, wellness-based classroom guidance unit was developed based on the Indivisible Self wellness model and presented to 55 students in 5th grade. Participants completed the Five Factor Wellness Inventory, Elementary School Version, before and after the unit. Wellness scores were significantly and positively higher at post-testing for…
The Causal Effect of Education on Health: Evidence from the United Kingdom
ERIC Educational Resources Information Center
Silles, Mary A.
2009-01-01
Numerous economic studies have shown a strong positive correlation between health and years of schooling. The question at the centre of this research is whether the correlation between health and education represents a causal relation. This paper uses changes in compulsory schooling laws in the United Kingdom to test this hypothesis. Multiple…
Investigational Testing for Zika Virus among U.S. Blood Donors.
Saá, Paula; Proctor, Melanie; Foster, Gregory; Krysztof, David; Winton, Colleen; Linnen, Jeffrey M; Gao, Kui; Brodsky, Jaye P; Limberger, Ronald J; Dodd, Roger Y; Stramer, Susan L
2018-05-10
Because of the potential severe clinical consequences of Zika virus (ZIKV) infection, the large numbers of asymptomatic travelers returning from ZIKV-active areas, the detection of ZIKV nucleic acid in blood, and reports of transmission of ZIKV through transfusion, in 2016 the Food and Drug Administration released recommendations for individual-unit nucleic acid testing to minimize the risk of transmission of ZIKV through blood transfusions. The American Red Cross implemented investigational screening of donated blood for ZIKV RNA by means of transcription-mediated amplification (TMA). Confirmatory testing of reactive donations involved repeat TMA, TMA testing in exploratory minipools, real-time reverse-transcriptase polymerase chain reaction, IgM serologic testing, and red-cell TMA. Viral loads in plasma and red cells were estimated by means of end-point TMA. The costs of interdicting a donation that was confirmed to be positive were calculated for the 15-month period between June 2016 and September 2017. Of the 4,325,889 donations that were screened, 393,713 (9%) were initially tested in 24,611 minipools, and no reactive donations were found. Of the 3,932,176 donations that were subsequently tested individually, 160 were initially reactive and 9 were confirmed positive (a 1:480,654 confirmed-positive rate overall; positive predictive value, 5.6%; specificity, 99.997%). Six (67%) of the confirmed-positive donations were reactive on repeat TMA, of which 4 were IgM-negative; of these 4, all 3 that could be tested were reactive on minipool TMA. Two confirmed-positive donors had infections that had been transmitted locally (in Florida), 6 had traveled to ZIKV-active areas, and 1 had received an experimental ZIKV vaccine. ZIKV RNA levels in red cells ranged from 40 to 800,000 copies per milliliter and were detected up to 154 days after donation, as compared with 80 days of detection in plasma at levels of 12 to 20,000 copies per milliliter. On the basis of industry-reported costs of testing and the yield of the tests in our study, the cost of identifying 8 mosquito-borne ZIKV infections through individual-unit nucleic acid testing was $5.3 million per ZIKV RNA-positive donation. Screening of U.S. blood donations for ZIKV by individual-donation TMA was costly and had a low yield. Among the 9 confirmed ZIKV-positive donations, only 4 were IgM-negative; of these donations, all 3 that were tested were reactive on minipool TMA. (Funded by the American Red Cross and Grifols Diagnostic Solutions.).
Wingate, La'Marcus T; Coleman, Margaret S; de la Motte Hurst, Christopher; Semple, Marie; Zhou, Weigong; Cetron, Martin S; Painter, John A
2015-12-01
This study explored the effect of screening and treatment of refugees for latent tuberculosis infection (LTBI) before entrance to the United States as a strategy for reducing active tuberculosis (TB). The purpose of this study was to estimate the costs and benefits of LTBI screening and treatment in United States bound refugees prior to arrival. Costs were included for foreign and domestic LTBI screening and treatment and the domestic treatment of active TB. A decision tree with multiple Markov nodes was developed to determine the total costs and number of active TB cases that occurred in refugee populations that tested 55, 35, and 20 % tuberculin skin test positive under two models: no overseas LTBI screening and overseas LTBI screening and treatment. For this analysis, refugees that tested 55, 35, and 20 % tuberculin skin test positive were divided into high, moderate, and low LTBI prevalence categories to denote their prevalence of LTBI relative to other refugee populations. For a hypothetical 1-year cohort of 100,000 refugees arriving in the United States from regions with high, moderate, and low LTBI prevalence, implementation of overseas screening would be expected to prevent 440, 220, and 57 active TB cases in the United States during the first 20 years after arrival. The cost savings associated with treatment of these averted cases would offset the cost of LTBI screening and treatment for refugees from countries with high (net cost-saving: $4.9 million) and moderate (net cost-saving: $1.6 million) LTBI prevalence. For low LTBI prevalence populations, LTBI screening and treatment exceed expected future TB treatment cost savings (net cost of $780,000). Implementing LTBI screening and treatment for United States bound refugees from countries with high or moderate LTBI prevalence would potentially save millions of dollars and contribute to United States TB elimination goals. These estimates are conservative since secondary transmission from tuberculosis cases in the United States was not considered in the model.
HIV testing behaviors of a cohort of HIV-positive racial/ethnic minority YMSM.
Phillips, Gregory; Hightow-Weidman, Lisa B; Arya, Monisha; Fields, Sheldon D; Halpern-Felsher, Bonnie; Outlaw, Angulique Y; Wohl, Amy R; Hidalgo, Julia
2012-10-01
The HIV epidemic in the United States has disproportionately affected young racial/ethnic minority men who have sex with men (YMSM). However, HIV testing rates among young men of color remain low. Within this sample of racial/ethnic minority YMSM (n = 363), the first HIV test was a median of 2 years after men who have sex with men sexual debut. Individuals with less than 1 year between their first negative and first positive HIV test were significantly more likely to identify the reason for their first negative test as being sick (OR = 2.99; 95 % CI 1.23-7.27). This may suggest that these YMSM may have experienced symptoms of acute HIV infection. Of major concern is that many YMSM in our study tested positive for HIV on their first HIV test. Given recommendations for at least annual HIV testing, our findings reveal that medical providers YMSM need to know the importance of regular testing.
Apheresis for collection of Ebola convalescent plasma in Liberia.
Brown, Jerry F; Rowe, Kathleen; Zacharias, Peter; van Hasselt, James; Dye, John M; Wohl, David A; Fischer, William A; Cunningham, Coleen K; Thielman, Nathan M; Hoover, David L
2017-06-01
This report describes initiation of apheresis capability in Liberia, Africa to support a clinical trial of convalescent plasma therapy for Ebola Virus Disease. A bloodmobile was outfitted in the United States as a four-bed apheresis unit with capabilities including pathogen reduction, electronic blood establishment computer system, designated areas for donor counseling and laboratory testing, and onboard electrical power generation. After air transport to Liberia, the bloodmobile was positioned at ELWA Hospital, Monrovia, and connected to the hospital's power grid. Liberian staff were trained to conduct donor screening, which included questionnaire and onsite blood typing and transfusion transmitted infection (TTI) testing, and plasma collection and processing. The bloodmobile was operational within 3 weeks after arrival of the advance team. Of 101 donors who passed the pre-screening questionnaire, 32 were deferred. Twenty-eight of ninty-nine tested survivors were deferred for positive transfusion transmitted infection (TTI) tests; twenty-one were positive for hepatitis B, hepatitis C, or human immunodeficiency virus. The majority of donors had type O blood; all but one were Rh positive. Forty-three survivors donated at least once; eighty-nine apheresis attempts resulted in eighty-one successful collections. Apheresis capability was emergently established in Liberia to support an efficacy trial of Ebola Convalescent Plasma. Extensive cooperation among multinational team members, engineers, logisticians, and blood safety technical personnel at the operational site was required to surmount challenges to execution posed by logistical factors. The high proportion of positive TTI tests supported the use of a pathogen reduction system to enhance product safety. J. Clin. Apheresis 32:175-181, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Diercks, Deborah B; Kirk, J Douglas; Turnipseed, Samuel D; Amsterdam, Ezra A
2007-12-01
Risk of acute coronary events in patients with methamphetamine and cocaine intoxication has been described. Little is known about the need for additional evaluation in these patients who do not have evidence of myocardial infarction after the initial emergency department evaluation. We herein describe our experience with these patients in a chest pain unit (CPU) and the rate of cardiac-related chest pain in this group. Retrospective analysis of patients evaluated in our CPU from January 1, 2000 to December 16, 2004 with a history of chest pain. Patients who had a positive urine toxicologic screen for methamphetamine or cocaine were included. No patients had ECG or cardiac injury marker evidence of myocardial infarction or ischemia during the initial emergency department evaluation. A diagnosis of cardiac-related chest pain was based upon positive diagnostic testing (exercise stress testing, nuclear perfusion imaging, stress echocardiography, or coronary artery stenosis >70%). During the study period, 4568 patients were evaluated in the CPU. A total of 1690 (37%) of patients admitted to the CPU underwent urine toxicologic testing. The result of urine toxicologic test was positive for cocaine or methamphetamine in 224 (5%). In the 2871 patients who underwent diagnostic testing for coronary artery disease (CAD), 401 (14%) were found to have positive results. There was no difference in the prevalence of CAD between those with positive result for toxicology screens (26/156, 17%) and those without (375/2715, 13%, RR 1.2, 95% CI 0.8-1.7). These findings suggest a relatively high rate of CAD in patients with methamphetamine and cocaine use evaluated in a CPU.
Characteristics of HIV-Positive Transgender Men Receiving Medical Care: United States, 2009-2014.
Lemons, Ansley; Beer, Linda; Finlayson, Teresa; McCree, Donna Hubbard; Lentine, Daniel; Shouse, R Luke
2018-01-01
To present the first national estimate of the sociodemographic, clinical, and behavioral characteristics of HIV-positive transgender men receiving medical care in the United States. This analysis included pooled interview and medical record data from the 2009 to 2014 cycles of the Medical Monitoring Project, which used a 3-stage, probability-proportional-to-size sampling methodology. Transgender men accounted for 0.16% of all adults and 11% of all transgender adults receiving HIV medical care in the United States from 2009 to 2014. Of these HIV-positive transgender men receiving medical care, approximately 47% lived in poverty, 69% had at least 1 unmet ancillary service need, 23% met criteria for depression, 69% were virally suppressed at their last test, and 60% had sustained viral suppression over the previous 12 months. Although they constitute a small proportion of all HIV-positive patients, more than 1 in 10 transgender HIV-positive patients were transgender men. Many experienced socioeconomic challenges, unmet needs for ancillary services, and suboptimal health outcomes. Attention to the challenges facing HIV-positive transgender men may be necessary to achieve the National HIV/AIDS Strategy goals of decreasing disparities and improving health outcomes among transgender persons.
Ormondroyd, Elizabeth; Donnelly, Louise; Moynihan, Clare; Savona, Cornelie; Bancroft, Elizabeth; Evans, D Gareth; Eeles, Rosalind; Lavery, Stuart; Watson, Maggie
2012-01-01
The scope of conditions for which preimplantation genetic diagnosis (PGD) is licensed has recently been expanded in the United Kingdom to include genetic predisposition to adult-onset cancer. This qualitative interview study explores reproductive decision making, knowledge of and attitudes to reproductive genetic testing (prenatal diagnosis and PGD) with 25 women aged 18–45 years who received a positive BRCA test in the United Kingdom before having children. In this cohort of younger women, BRCA testing was motivated by risk management decisions; for some, BRCA status has affected their later decisions about having children. The perceived severity of hereditary breast/ovarian cancer (HBOC) influences thoughts about passing on the mutation to children and willingness to consider reproductive genetic testing, but most participants do not believe HBOC is a condition for which pregnancy termination is justified. PGD is considered more acceptable and advantageous because it would prevent transmission to future generations, but women have concerns about selecting embryos and the fact that they and affected family members would not have been selected. Women would also be deterred by the need to undergo in vitro fertilisation (IVF) and ovarian stimulation for PGD. Awareness of reproductive testing options was very variable among the cohort. The findings highlight the complexities of reproductive decision making for young women who knowingly carry a BRCA mutation, and the dilemmas inherent to reproductive genetic testing when the condition being tested for also affects a prospective parent. Counselling and psychological support for BRCA-positive women and couples concerning reproductive options are strongly indicated. PMID:21811309
Del Eckels, Joel [Livermore, CA; Nunes, Peter J [Danville, CA; Simpson, Randall L [Livermore, CA; Whipple, Richard E [Livermore, CA; Carter, J Chance [Livermore, CA; Reynolds, John G [San Ramon, CA
2010-08-10
An inspection tester system for testing for explosives. The tester includes a body and a swab unit adapted to be removeably connected to the body. At least one reagent holder and dispenser is operatively connected to the body. The reagent holder and dispenser contains an explosives detecting reagent and is positioned to deliver the explosives detecting reagent to the swab unit. A heater is operatively connected to the body and the swab unit is adapted to be operatively connected to the heater.
THE DISTRIBUTION OF COCCIDIOIDOMYCOSIS IN SOUTHERN CALIFORNIA
Kessel, John F.; Biddle, Marjorie; Tucker, Harold A.; Yeaman, Antoinette
1950-01-01
In coccidioidin skin test surveys among persons of high school age in Saugus, Canoga Park, Banning and Palm Springs areas the average incidence of positive reaction was 15 per cent. Although considerably less than the 68 per cent incidence reported among high school students of Kern County, it is high enough to indicate pockets of relatively high endemicity in Southern California below the San Joaquin Valley. Histoplasmin tests were performed on most of the persons tested with coccidioidin in this survey. The over-all incidence of positive reaction in the group was 7.6 per cent. Most of the subjects with positive reaction to histoplasmin gave a history of having previously lived in some area in the central United States where histoplasmosis is known to be endemic. A few subjects who had positive reaction to coccidioidin tests and who had lived in areas known to be endemic for coccidioidomycosis but not for histoplasmosis, also had positive reaction to histoplasmin. However, the induration produced was always smaller than that caused by the coccidioidin reaction, and there was minimal confusion in interpreting the tests. PMID:14772654
HLA-B*5701 clinical testing: early experience in the United States.
Faruki, Hawazin; Heine, Uwe; Brown, Trisha; Koester, Ruth; Lai-Goldman, Myla
2007-10-01
HLA-B*5701 testing to provide risk stratification for abacavir hypersensitivity has the potential to reduce incidence of hypersensitivity reactions in susceptible individuals. Early experience with clinical HLA-B*5701 testing of the first 100 specimens, from a large clinical reference laboratory in the United States, is presented. Patient samples were tested using a two-step approach. The first step allowed rapid identification of most HLA-B*5701-negative samples in a high throughput mode. The second step involved resolution of putative positives by DNA sequencing to identify B*5701 specifically as well as other B57 subtypes. Test reporting included a phone call from a genetic counselor to obtain the ethnic background and indication for testing and to provide a patient-specific interpretation. The patients population was comprised of Caucasians, 84%; Hispanics, 13%; and African Americans, 3%. Among the 100 samples tested, 92% were HLA-B*5701-negative and 8% were positive for the HLA-B*5701 allele. All HLA-B*5701 allele positives were identified in Caucasian patients. Where the indication for testing was obtainable (57 patients), pre-abacavir therapy screening was the indication 67% of the time. Clarification of previous suspected history of hypersensitivity was the indication 33% of the time. Among samples tested to help clarify a previous history of hypersensitivity, 16/19 or 84% did not carry the HLA-B*5701 allele whereas 3/19 (16%) were carriers of the HLA-B*5701 allele. Early utilization of HLA-B*5701 testing in community practice was not always consistent with the clinical indications for testing. Post-test communication assisted in providing physician education and interpretation of patient-specific results.
Moses, Erin; Pedersen, Heather N; Mitchell, Sheona M; Sekikubo, Musa; Mwesigwa, David; Singer, Joel; Biryabarema, Christine; Byamugisha, Josaphat K; Money, Deborah M; Ogilvie, Gina S
2015-10-01
To compare two cervical cancer screening methods: community-based self-collection of high-risk human papillomavirus (HR-HPV) testing and visual inspection with acetic acid (VIA). Pilot randomised controlled trial of 500 women aged 30-65 in the community of Kisenyi, Uganda. Women randomised to self-collection-based HR-HPV testing provided a cervico-vaginal swab for HR-HPV, and results were provided by phone after laboratory testing. Women who tested HPV positive were referred for VIA at the local health unit. Women randomised to VIA underwent screening at the local health unit, where women who tested positive with VIA were provided cryotherapy at time of screening, as per local standard of care. Women were referred for colposcopy when indicated. Outcome measures were uptake of screening, HR-HPV prevalence, VIA result and treatment rates. In the HR-HPV arm, 248 of 250 (p < 0.01) women provided samples, while in the VIA arm, 121 of 250 (48.4%) women attended screening. Among the 73 of 248 HR-HPV-positive women, 45.2% (N = 33) attended VIA screening for follow-up, 21.2% (N = 7) of whom screened positive; five received treatment and two were missing clinical follow-up records. Of the 121 women in the VIA arm who attended screening, 13.2% (N = 16) screened positive; seven received cryotherapy, three refused treatment, five were referred to colposcopy; and one woman had suspected cervical cancer and received treatment after confirmatory testing. This pilot study demonstrated trial feasibility and willingness of the women to participate and be randomised successfully into the two arms. Self-collection-based cervical cancer screening had a higher uptake than VIA. © 2015 John Wiley & Sons Ltd.
Testing Instrument for Flight-Simulator Displays
NASA Technical Reports Server (NTRS)
Haines, Richard F.
1987-01-01
Displays for flight-training simulators rapidly aligned with aid of integrated optical instrument. Calibrations and tests such as aligning boresight of display with respect to user's eyes, checking and adjusting display horizon, checking image sharpness, measuring illuminance of displayed scenes, and measuring distance of optical focus of scene performed with single unit. New instrument combines all measurement devices in single, compact, integrated unit. Requires just one initial setup. Employs laser and produces narrow, collimated beam for greater measurement accuracy. Uses only one moving part, double right prism, to position laser beam.
1979-09-01
DIVISION" TEST Edwin R. Smutz ARI FIELD UNIT AT FORT HOOD, TEXAS C/ C,; U. S. Army Research Institute for the Behavioral and Social Sciences I Ir September... SCIENCES A Field Operating Agency under the Jurisdiction of the Deputy Chief of Staff for Personnel WILLIAM L. HAUSERi JOSEPH ZEIDNER Colonel, U S Army...Behavioral and Social Sciences . fj The findings in this report are not to be construed as an official Departmeint of the Army Position, unions so
Needleman, Jack; Pearson, Marjorie L; Upenieks, Valda V; Yee, Tracy; Wolstein, Joelle; Parkerton, Melissa
2016-02-01
Process improvement stresses the importance of engaging frontline staff in implementing new processes and methods. Yet questions remain on how to incorporate these activities into the workday of hospital staff or how to create and maintain its commitment. In a 15-month American Organization of Nurse Executives collaborative involving frontline medical/surgical staff from 67 hospitals, Transforming Care at the Bedside (TCAB) was evaluated to assess whether participating units successfully implemented recommended change processes, engaged staff, implemented innovations, and generated support from hospital leadership and staff. In a mixed-methods analysis, multiple data sources, including leader surveys, unit staff surveys, administrative data, time study data, and collaborative documents were used. All units reported establishing unit-based teams, of which >90% succeeded in conducting tests of change, with unit staff selecting topics and making decisions on adoption. Fifty-five percent of unit staff reported participating in unit meetings, and 64%, in tests of change. Unit managers reported substantial increase in staff support for the initiative. An average 36 tests of change were conducted per unit, with 46% of tested innovations sustained, and 20% spread to other units. Some 95% of managers and 97% of chief nursing officers believed that the program had made unit staff more likely to initiate change. Among staff, 83% would encourage adoption of the initiative. Given the strong positive assessment of TCAB, evidence of substantial engagement of staff in the work, and the high volume of innovations tested, implemented, and sustained, TCAB appears to be a productive model for organizing and implementing a program of frontline-led improvement.
Asymptomatic Lymphogranuloma Venereum in Men who Have Sex with Men, United Kingdom
Saxon, Cara; Ison, Catherine
2016-01-01
We investigated prevalence of lymphogranuloma venereum (LGV) among men who have sex with men who were tested for chlamydia at 12 clinics in the United Kingdom during 10 weeks in 2012. Of 713 men positive for Chlamydia trachomatis, 66 (9%) had LGV serovars; 15 (27%) of 55 for whom data were available were asymptomatic. PMID:26691688
Cultural Perspectives on Aging and Well-Being: A Comparison of Japan and the United States
ERIC Educational Resources Information Center
Karasawa, Mayumi; Curhan, Katherine B.; Markus, Hazel Rose; Kitayama, Shinobu S.; Love, Gayle Dienberg; Radler, Barry T.; Ryff, Carol D.
2011-01-01
This study investigated age differences in multiple aspects of psychological well-being among midlife and older adults in Japan (N = 482) and the United States (N = 3,032) to test the hypothesis that older Japanese adults would rate aspects of their well-being (personal growth, purpose in life, positive relations with others) more highly that…
Carvalho, Rodrigo; Maio, Paula; Amaro, Cristina; Santos, Raquel; Cardoso, Jorge
2011-09-01
Hydroxyisohexyl 3-cyclohexene carboxaldehyde (HICC)-Lyral® is a widely used synthetic fragrance found in personal care and household products. It is an aldehyde, lipophilic enough to penetrate the skin and is a frequent cause of contact sensitization. Describe the frequency of contact allergy to HICC in a Contact Dermatitis Unit, after its inclusion in baseline patch test series. A retrospective study including all patients submitted to patch test, from January 2007 to December 2009. Over a 3-year period, 629 consecutive patients were patch tested. The frequency of positive reactions to HICC was 2.7% (17/629). Of the positive patients, 35% (6/17) gave a history of atopy, 58.8% (10/17) had eczema on the face and neck, 23.5% (4/17) on the hands, 23.5% (4/17) in the axillae, 17.6% (3/17) on the trunk and 6% (3/17) had generalized eczema. All patients were patch positive for more than one allergen: all (17/17) positive to fragrance Mix 2 (FM2); 47% of the patients (8/17) positive to fragrance Mix 1 (FM1); and 23.5% of the patients (4/17) positive to Balsam of Peru. In 94% (16/17) of cases, the reaction was judged to be of current relevance. The frequency of positive reactions to HICC of 2.7% found in our population is according to what is described in several European reports, where HICC is still widely used as a fragrance ingredient. In contrast, in North America, the prevalence is lower. All the patients were positive also to FM2. The association found between reactions to FM1 and HICC is also commonly reported and could represent a concomitant sensitization following increased exposure to fragrance allergens. These data confirm the importance of HICC introduction in the baseline patch test series.
Jorgensen, James H.; Salinas, Jesse R.; Paxson, Rosemary; Magnon, Karen; Patterson, Jan E.; Patterson, Thomas F.
1999-01-01
The Gen-Probe Amplified Mycobacterium Tuberculosis Direct (MTD) test has been approved for use in the United States for the rapid diagnosis of pulmonary tuberculosis in patients with acid-fast smear-positive sputum samples since 1996. Four patients infected with human immunodeficiency virus and one chronic pulmonary-disease patient seen in our institutions with abnormal chest radiographs and fluorochrome stain-positive sputa were evaluated for tuberculosis, including performance of the MTD test on expectorated sputum samples. Three of these five patients’ sputa were highly smear-positive (i.e., more than 100 bacilli per high-power field), while two patient’s sputa contained 1 to 10 bacilli per field. MTD results on sputum specimens from these patients ranged from 43,498 to 193,858 relative light units (RLU). Gen-Probe has defined values of at least 30,000 RLU as indicative of a positive test, i.e., the presence of Mycobacterium tuberculosis RNA. Four of the patients’ sputum cultures yielded growth of M. kansasii within 6 to 12 days, and the fifth produced growth of M. avium only. One patient’s culture contained both M. kansasii and M. avium, but none of the initial or follow-up cultures from these five patients revealed M. tuberculosis. However, subsequent cultures from three of the patients again revealed M. kansasii. During the period of this study, in which MTD tests were performed on smear-positive sputum specimens from 82 patients, four of seven patients with culture-proven M. kansasii pulmonary infections yielded one or more false-positive MTD tests. The MTD sensitivity observed in this study was 93.8%, and the specificity was 85.3%. Five cultures of M. kansasii (including three of these patients’ isolates and M. kansasii ATCC 12478), and cultures of several other species were examined at densities of 105 to 107 viable CFU/ml by the MTD test. All five isolates of M. kansasii and three of three isolates of M. simiae yielded false-positive test results, with readings of 75,191 to 335,591 RLU. These findings indicate that low-level false-positive MTD results can occur due to the presence of M. kansasii, M. avium, and possibly other Mycobacterium species other than M. tuberculosis in sputum. Low-level positive MTD results of 30,000 to 500,000 RLU should be interpreted in light of these findings. It remains to be determined if the enhanced MTD test (MTD 2) recently released by Gen-Probe will provide greater specificity than that observed in this report with its first-generation test. PMID:9854086
Bordetella parapertussis outbreak in Southeastern Minnesota and the United States, 2014.
Karalius, Vytas P; Rucinski, Stefanea L; Mandrekar, Jayawant N; Patel, Robin
2017-05-01
Whooping cough is traditionally ascribed to Bordetella pertussis; however, Bordetella parapertussis can cause a similar clinical syndrome. This study describes an outbreak of B. parapertussis in Southeastern Minnesota and the United States (US) in 2014. This was a retrospective analysis of Mayo Clinic and Mayo Medical Laboratories patients who tested positive for B. parapertussis from 2012 to 2014. The medical records of Mayo Clinic patients who tested positive in 2014 were reviewed for demographic information, presenting symptoms, disease course, and vaccination history. In Southeast Minnesota, 81% of the 31 patients who tested positive for B. parapertussis in 2014 were found to be positive from October through December. Their mean age was 5.9 years. Five reported "exposure to pertussis." Two pairs of siblings were affected. Patients reported having had symptoms for an average of 2.6 weeks before nasopharyngeal specimen collection for B. parapertussis testing. Cough was the primary symptom reported. Forty percent reported posttussive vomiting, 40% coryza, 32% apnea/sleep disturbance, and 12% sore throat. All were current with pertussis vaccination. Based on the review of national data, an outbreak occurred nationally in the Northeast and Midwest US over the same time period. In 2014, there was an outbreak of B. parapertussis in Southeastern Minnesota and likely other parts of the US. The presenting illness was similar to that of B. pertussis. All patients were vaccinated against pertussis, suggesting that pertussis vaccination is ineffective against B. parapertussis.
False-positive LSD testing in urine samples from intensive care patients.
Röhrich, J; Zörntlein, S; Lotz, J; Becker, J; Kern, T; Rittner, C
1998-09-01
Unexpected positive results for lysergic acid diethylamide (LSD) were found in urine samples from 12 patients in an intensive care unit in a routine screening using the CEDIA DAU assay. None of these test results could be confirmed by high-performance liquid chromatography analysis, but all samples contained the mucolytic drug ambroxol. Further studies demonstrated that ambroxol exhibits a significant cross-reactivity in the CEDIA DAU LSD assay. Therefore, positive LSD results obtained with the CEDIA DAU assay have to be critically evaluated, particularly during the cold season, when infections of the respiratory tract often result in more frequent use of mucolytic medications.
Beta-lactam resistance and Enterobacteriaceae, United States.
Whichard, Jean M; Joyce, Kevin; Fey, Paul D; Nelson, Jennifer M; Angulo, Frederick J; Barrett, Timothy J
2005-09-01
Extended-spectrum cephalosporins (ESC) are an important drug class for treating severe Salmonella infections. We screened the human collection from the National Antimicrobial Resistance Monitoring System 2000 for ESC resistance mechanisms. Of non-Typhi Salmonella tested, 3.2% (44/1,378) contained blaCMY genes. Novel findings included blaCMY-positive Escherichia coli O157:H7 and a blaSHV-positive Salmonella isolate. CMY-positive isolates showed a ceftriaxone MIC > or =2 microg/mL.
Language Facility and Theory of Mind Development in Deaf Children.
ERIC Educational Resources Information Center
Jackson, A. Lyn
2001-01-01
Deaf children with signing parents, nonnative signing deaf children, children from a hearing impaired unit, oral deaf children, and hearing controls were tested on theory of Mind (ToM) tasks and a British sign language receptive language test. Language ability correlated positively and significantly with ToM ability. Age underpinned the…
Mobile Phones: Potential Sources of Nickel and Cobalt Exposure for Metal Allergic Patients
Mucci, Tania; Chong, Melanie; Lorton, Mark Davis; Fonacier, Luz
2013-01-01
The use of cellular phones has risen exponentially with over 300 million subscribers. Nickel has been detected in cell phones and reports of contact dermatitis attributable to metals are present in the literature. We determined nickel and cobalt content in popular cell phones in the United States. Adults (>18 years) who owned a flip phone, Blackberry®, or iPhone® were eligible. Seventy-two cell phones were tested using SmartPractice's® commercially available nickel and cobalt spot tests. Test areas included buttons, keypad, speakers, camera, and metal panels. Of the 72 cell phones tested, no iPhones or Droids® tested positive for nickel or cobalt. About 29.4% of Blackberrys [95% confidence interval (CI), 13%–53%] tested positive for nickel; none were positive for cobalt. About 90.5% of flip phones (95% CI, 70%–99%) tested positive for nickel and 52.4% of flip phones (95% CI, 32%–72%) tested positive for cobalt. Our study indicates that nickel and cobalt are present in popular cell phones. Patients with known nickel or cobalt allergy may consider their cellular phones as a potential source of exposure. Further studies are needed to examine whether there is a direct association with metal content in cell phones and the manifestation of metal allergy. PMID:24380018
Qian, Jing; Wang, Bin; Han, Zhuo; Song, Baihe
2017-01-01
This research elucidates the role of ethical leadership in employee feedback seeking by examining how and when ethical leadership may exert a positive influence on feedback seeking. Using matched reports from 64 supervisors and 265 of their immediate employees from a hotel group located in a major city in China, we proposed and tested a moderated mediation model that examines leader-member exchange (LMX) as the mediator and emotional intelligence as well as work-unit structure as double moderators in the relationships between ethical leadership and followers’ feedback-seeking behavior from supervisors and coworkers. Our findings indicated that (1) LMX mediated the positive relationship between ethical leadership and feedback seeking from both ethical leaders and coworkers, and (2) emotional intelligence and work-unit structure served as joint moderators on the mediated positive relationship in such a way that the relationship was strongest when the emotional intelligence was high and work-unit structure was more of an organic structure rather than a mechanistic structure. PMID:28744251
Pfaller, M. A.; Sader, H. S.; Rhomberg, P. R.
2017-01-01
ABSTRACT The in vitro activities of delafloxacin and comparator antimicrobial agents against 6,485 bacterial isolates collected from medical centers in Europe and the United States in 2014 were tested. Delafloxacin was the most potent agent tested against methicillin-susceptible Staphylococcus aureus (MSSA), methicillin-resistant S. aureus, Streptococcus pneumoniae, viridans group streptococci, and beta-hemolytic streptococci and had activity similar to that of ciprofloxacin and levofloxacin against certain members of the Enterobacteriaceae. Overall, the broadest coverage of the tested pathogens (Gram-positive cocci and Gram-negative bacilli) was observed with meropenem and tigecycline in both Europe and the United States. Delafloxacin was shown to be active against organisms that may be encountered in acute bacterial skin and skin structure infections, respiratory infections, and urinary tract infections. PMID:28167542
Pfaller, M A; Sader, H S; Rhomberg, P R; Flamm, R K
2017-04-01
The in vitro activities of delafloxacin and comparator antimicrobial agents against 6,485 bacterial isolates collected from medical centers in Europe and the United States in 2014 were tested. Delafloxacin was the most potent agent tested against methicillin-susceptible Staphylococcus aureus (MSSA), methicillin-resistant S. aureus , Streptococcus pneumoniae , viridans group streptococci, and beta-hemolytic streptococci and had activity similar to that of ciprofloxacin and levofloxacin against certain members of the Enterobacteriaceae Overall, the broadest coverage of the tested pathogens (Gram-positive cocci and Gram-negative bacilli) was observed with meropenem and tigecycline in both Europe and the United States. Delafloxacin was shown to be active against organisms that may be encountered in acute bacterial skin and skin structure infections, respiratory infections, and urinary tract infections. Copyright © 2017 Pfaller et al.
Design and Implementation of High Precision Temperature Measurement Unit
NASA Astrophysics Data System (ADS)
Zeng, Xianzhen; Yu, Weiyu; Zhang, Zhijian; Liu, Hancheng
2018-03-01
Large-scale neutrino detector requires calibration of photomultiplier tubes (PMT) and electronic system in the detector, performed by plotting the calibration source with a group of designated coordinates in the acrylic sphere. Where the calibration source positioning is based on the principle of ultrasonic ranging, the transmission speed of ultrasonic in liquid scintillator of acrylic sphere is related to temperature. This paper presents a temperature measurement unit based on STM32L031 and single-line bus digital temperature sensor TSic506. The measurement data of the temperature measurement unit can help the ultrasonic ranging to be more accurate. The test results show that the temperature measurement error is within ±0.1°C, which satisfies the requirement of calibration source positioning. Take energy-saving measures, with 3.7V/50mAH lithium battery-powered, the temperature measurement unit can work continuously more than 24 hours.
Reksen, O; Sølverød, L; Østerås, O
2008-08-01
Associations between test-day composite milk somatic cell counts (CMSCC) and results from quarter milk cultures for various pathogens associated with mastitis, including Staphylococcus aureus, Streptococcus spp., coagulase-negative staphylococci (CNS), were investigated. S. aureus was dichotomized according to sparse (
Results of the long range position-determining system tests. [Field Army system
NASA Technical Reports Server (NTRS)
Rhode, F. W.
1973-01-01
The long range position-determining system (LRPDS) has been developed by the Corps of Engineers to provide the Field Army with a rapid and accurate positioning capability. The LRPDS consists of an airborne reference position set (RPS), up to 30 ground based positioning sets (PS), and a position computing central (PCC). The PCC calculates the position of each PS based on the range change information provided by each Set. The positions can be relayed back to the PS again via RPS. Each PS unit contains a double oven precise crystal oscillator. The RPS contains a Hewlett-Packard cesium beam standard. Frequency drifts and off-sets of the crystal oscillators are taken in account in the data reduction process. A field test program was initiated in November 1972. A total of 54 flights were made which included six flights for equipment testing and 48 flights utilizing the field test data reduction program. The four general types of PS layouts used were: short range; medium range; long range; tactical configuration. The overall RMS radial error of the unknown positions varied from about 2.3 meters for the short range to about 15 meters for the long range. The corresponding elevation RMS errors vary from about 12 meters to 37 meters.
[Variations in the diagnostic confirmation process between breast cancer mass screening units].
Natal, Carmen; Fernández-Somoano, Ana; Torá-Rocamora, Isabel; Tardón, Adonina; Castells, Xavier
2016-01-01
To analyse variations in the diagnostic confirmation process between screening units, variations in the outcome of each episode and the relationship between the use of the different diagnostic confirmation tests and the lesion detection rate. Observational study of variability of the standardised use of diagnostic and lesion detection tests in 34 breast cancer mass screening units participating in early-detection programmes in three Spanish regions from 2002-2011. The diagnostic test variation ratio in percentiles 25-75 ranged from 1.68 (further appointments) to 3.39 (fine-needle aspiration). The variation ratio in detection rates of benign lesions, ductal carcinoma in situ and invasive cancer were 2.79, 1.99 and 1.36, respectively. A positive relationship between rates of testing and detection rates was found with fine-needle aspiration-benign lesions (R(2): 0.53), fine-needle aspiration-invasive carcinoma (R(2): 0 28), core biopsy-benign lesions (R(2): 0.64), core biopsy-ductal carcinoma in situ (R(2): 0.61) and core biopsy-invasive carcinoma (R(2): 0.48). Variation in the use of invasive tests between the breast cancer screening units participating in early-detection programmes was found to be significantly higher than variations in lesion detection. Units which conducted more fine-needle aspiration tests had higher benign lesion detection rates, while units that conducted more core biopsies detected more benign lesions and cancer. Copyright © 2016 SESPAS. Published by Elsevier Espana. All rights reserved.
NASA Astrophysics Data System (ADS)
Slykhuis, David A.
This research project examined the efficacy of an online microcomputer-based laboratory based (MBL) physics unit. One hundred and fifty physics students from five high schools in North Carolina were divided into online and classroom groups. The classroom group completed the MBL unit in small groups with assistance from their teachers. The online groups completed the MBL unit in small groups using a website designed for this project for guidance. Pre- and post-unit content specific tests and surveys were given. Statistical analysis of the content tests showed significant development of conceptual understanding by the online group over the course of the unit. There was not a significant difference between the classroom and online group with relation to the amount of conceptual understanding developed. Correlations with post-test achievement showed that pre-test scores and math background were the most significant correlates with success. Computer related variables, such as computer comfort and online access, were only mildly correlated with the online group. Students' views about the nature of physics were not well developed prior to the unit and did not significantly change over the course of the unit. Examination of the students' physics conceptions after instruction revealed common alternative conceptions such as confusing position and velocity variables and incorrect interpretations of graphical features such as slope.
Free the animals? Investigating attitudes toward animal testing in Britain and the United States.
Swami, Viren; Furnham, Adrian; Christopher, Andrew N
2008-06-01
In this study, 185 British and 143 American undergraduates completed a battery of tests that measured attitudes toward animal testing and various individual difference variables. Attitudes toward animal testing factored into two interpretable factors: general attitudes toward animal testing, and animal welfare and conditions of testing. Overall, there was support for animal testing under the right conditions, although there was also concern for the welfare of animals and the conditions under which testing takes place. There were small but significant national difference on both factors (with Americans more positive about testing and less positive about animal welfare), and a significant sex difference on the first factor (women were more negative about testing). Correlation and regression analyses showed that there were few significant individual difference predictors of both factors. These results are discussed in relation to past and future work on attitudes toward animal testing.
Management of infants born to women infected with hepatitis B in the military healthcare system.
Sainato, Rebecca J; Simmons, Elizabeth G; Muench, Dawn F; Burnett, Mark W; Braun, LoRanée
2013-08-28
Hepatitis B virus (HBV) is endemic worldwide. Given significant rates of infectivity, all infants born to Hepatitis B surface antigen positive mothers need to receive treatment at birth, immunization and post-vaccination serologic testing. However, not all infants complete these requirements. We performed a retrospective review of the management of infants born to Hepatitis B infected mothers at two large military hospitals in the United States that use a global electronic medical record to track patient results. We then compared these results to those recently published by the National Perinatal Hepatitis B Prevention Program (PHBPP), which does not include hospitals in the United States Military Healthcare System. Our results show that although all infants were managed appropriately at birth and immunization rates were very high, post vaccination follow-up testing rates were much lower than those seen in centers participating in the PHBPP. The rates of post vaccination serological testing were significantly higher for infants born to Hepatitis B e antigen positive mothers and those referred to a pediatric infectious disease specialist. Despite use of a global electronic medical record in the United States Military Healthcare System, management of HBV-exposed infants does not always follow recommended guidelines. These infants could benefit from a more systematic method of follow-up, similar to the PHBPP, to ensure HBV serologic testing is obtained after the vaccination series is complete.
Olotu, Amadin A; Oyelese, Adesola O; Salawu, Lateef; Audu, Rosemary A; Okwuraiwe, Azuka P; Aboderin, Aaron O
2016-05-05
Hepatitis B virus (HBV) transmission through blood transfusion is reduced by screening for hepatitis B surface antigen (HBsAg). However this method cannot detect the presence of occult hepatitis B virus infection. This study sought to determine the prevalence of occult hepatitis B virus infection among blood donors in Ile-Ife, Nigeria. For the first time in Nigeria we employed an automated real-time PCR- method to investigate the prevalence of occult HBV in blood donors. Blood donors screened with HBsAg immunochromatographic rapid test kits at the blood transfusion units of two hospitals and found to be negative were recruited into the study. Questionnaires to elicit risk factors for HBV infection were administered and then 10 ml of blood was collected from each donor. Plasma samples obtained from these HBsAg negative blood donors were screened again for HBsAg using an enzyme-linked immunosorbent assay (ELISA) method, and those found negative were screened for the presence of total antibody to the HBV core antigen (anti-HBc) using ELISA method. Those positive to anti-HBc were then tested for HBV DNA, using an automated real-time PCR method. Five hundred and seven blood donors found HBsAg negative by immunochromatographic rapid test kits at both blood transfusion units, were tested for HBsAg using ELISA and 5 (1 %) were HBsAg positive. The 502 found negative were tested for anti-HBc and 354 (70.5 %) were found positive implying previous exposure to HBV and 19 (5.4 %) of the 354 anti-HBc positive had HBV DNA signifying occult HBV infection. No risk factors were found to be associated with the presence of HBV DNA among those who tested positive. Occult HBV infection exists in blood donors in Ile-Ife, Nigeria and the use of HBsAg alone for screening prospective donors will not eliminate the risk of HBV transmission in blood transfusion or stem cell transplantation.
NASA Astrophysics Data System (ADS)
Lawman, Adam; Straub, Jeremy; Kerlin, Scott
2015-05-01
This paper presents work conducted in preparation for a suborbital test flight to test an inertial measurement unit's (IMU's) ability to serve as a position determination mechanism in a GPS-denied environment. Because the IMU could potentially be used at several points during flight, it is not guaranteed that a GPS fix can be used to reset the IMU after the stresses of launch. Due to this, the specific goal of this work is to characterize whether a rocket launch disrupts the IMU-based position knowledge to the extent that it is unusable. This paper discusses preparations for a sub-orbital launch mission to this end. It include a description of the hardware and software used. A discussion of the data logging mechanism and the onboard and post-flight processing which is required to compare the GPS fixes and IMU-generated positions is also presented. Finally, the utility of an IMU capable of maintaining position awareness during launch is discussed.
Zavizion, B; Serebryanik, D; Chapman, J; Alford, B; Purmal, A
2004-10-01
The risk of transfusion-transmitted bacterial infections as a result of the presence of bacteria in blood is one of the major concerns in transfusion medicine. The purpose of this study was to investigate whether bacteria inoculated into red blood cell concentrates can be inactivated by the INACTINE PEN110 pathogen-reduction process. Four bacterial species were chosen for the study: anaerobic Gram-positive Clostridium perfringens and Propionibacterium acnes, known to be transfusion-transmitted; and two Gram-negative species, Acinetobacter johnsonii and Acinetobacter lwoffii, recently reported to be a common cause of transfusion-associated infections in Europe. Identical units of leucoreduced red cell concentrates were inoculated with A. johnsonii, A. lwoffii, C. perfringens, or P. acnes. The 4 degrees C control units were put on storage immediately after receiving the spike. The test units were subjected to PEN110 treatment and then stored. The bacterial titre in all units was monitored during a 6-week storage period. The PEN110 inactivation of all tested bacterial strains was time- and titre-dependent. For A. johnsonii and A. lwoffii, no viable bacteria were detected in the units spiked with up to 10(4) colony-forming units (CFU)/ml and treated with PEN110. For red cell units spiked with 10(4)-10(5) CFU/ml of C. perfringens and P. acnes, no viable bacteria were detected in the units treated with PEN110. In control units, there was a gradual decrease in A. johnsonii, A. lwoffii and C. perfringens titres during cold storage, while P. acnes titres remained stable. The PEN110 pathogen-reduction process was demonstrated to inactivate high titres of A. johnsonii, A. lwoffii, C. perfringens and P. acnes in red cell concentrates.
Parriott, Andrea; Malekinejad, Mohsen; Miller, Amanda P; Marks, Suzanne M; Horvath, Hacsi; Kahn, James G
2018-04-12
Homelessness increases the risk of tuberculosis (TB) disease and latent TB infection (LTBI), but persons experiencing homelessness often lack access to testing and treatment. We assessed the yield of TB testing and linkage to care for programs targeting homeless populations in the United States. We conducted a comprehensive search of peer-reviewed and grey literature, adapting Cochrane systematic review methods. Two reviewers independently assessed study eligibility and abstracted key data on the testing to care cascade: number of persons reached, recruited for testing, tested for LTBI, with valid test results, referred to follow-up care, and initiating care. We used random effects to calculate pooled proportions and 95% confidence intervals (CI) of persons retained in each step via inverse-variance weighted meta-analysis, and cumulative proportions as products of adjacent step proportions. We identified 23 studies published between 1986 and 2014, conducted in 12 states and 15 cities. Among studies using tuberculin skin tests (TST) we found that 93.7% (CI 72.4-100%) of persons reached were recruited, 97.9% (89.3-100%) of those recruited had tests placed, 85.5% (78.6-91.3%) of those with tests placed returned for reading, 99.9% (99.6-100%) of those with tests read had valid results, and 24.7% (21.0-28.5%) with valid results tested positive. All persons testing positive were referred to follow-up care, and 99.8% attended at least one session of follow-up care. Heterogeneity was high for most pooled proportions. For a hypothetical cohort of 1000 persons experiencing homelessness reached by a targeted testing program using TST, an estimated 917 were tested, 194 were positive, and all of these initiated follow-up care. Targeted TB testing of persons experiencing homelessness appears effective in detecting LTBI and connecting persons to care and potential treatment. Future evaluations should assess diagnostic use of interferon gamma release assays and completion of treatment, and costs of testing and treatment.
Nursing workload in public and private intensive care units
Nogueira, Lilia de Souza; Koike, Karina Mitie; Sardinha, Débora Souza; Padilha, Katia Grillo; de Sousa, Regina Marcia Cardoso
2013-01-01
Objective This study sought to compare patients at public and private intensive care units according to the nursing workload and interventions provided. Methods This retrospective, comparative cohort study included 600 patients admitted to 4 intensive care units in São Paulo. The nursing workload and interventions were assessed using the Nursing Activities Score during the first and last 24 hours of the patient's stay at the intensive care unit. Pearson's chi-square test, Fisher's exact test, the Mann-Whitney test, and Student's t test were used to compare the patient groups. Results The average Nursing Activities Score upon admission to the intensive care unit was 61.9, with a score of 52.8 upon discharge. Significant differences were found among the patients at public and private intensive care units relative to the average Nursing Activities Score upon admission, as well as for 12 out of 23 nursing interventions performed during the first 24 hours of stay at the intensive care units. The patients at the public intensive care units exhibited a higher average score and overall more frequent nursing interventions, with the exception of those involved in the "care of drains", "mobilization and positioning", and "intravenous hyperalimentation". The groups also differed with regard to the evolution of the Nursing Activities Score among the total case series as well as the groups of survivors from the time of admission to discharge from the intensive care unit. Conclusion Patients admitted to public and private intensive care units exhibit differences in their nursing care demands, which may help managers with nursing manpower planning. PMID:24213086
O'Brien, Sheila F; Fearon, Margaret A; Yi, Qi-Long; Fan, Wenli; Scalia, Vito; Muntz, Irene R; Vamvakas, Eleftherios C
2007-10-01
The benefit of introducing anti-hepatitis B core antigen (HBc) screening for intercepting potentially infectious donations missed by hepatitis B surface antigen (HBsAg) screening in Canada was studied. Anti-HBc testing of all donations was implemented in April 2005, along with antibody to hepatitis B surface antigen (anti-HBs) and hepatitis B virus (HBV) DNA supplemental testing of anti-HBc repeat-reactive, HBsAg-negative donations. The proportion of potentially infectious donations intercepted by anti-HBc over the initial 18 months of testing was calculated based on three assumptions relating infectivity of HBV DNA-positive units to anti-HBs levels. Lookback was conducted for all DNA-positive donations. Of 493,344 donors, 5,585 (1.13%) were repeat-reactive for the presence of anti-HBc, with 29 (0.52%) being HBV DNA-positive and HBsAg-negative. The proportion of potentially infectious donations intercepted by anti-HBc screening was 1 in 17,800 if all HBV DNA-positive donations were infectious, 1 in 26,900 if infectivity was limited to donations with an anti-HBs level of not more than 100 mIU per mL, and 1 in 69,300 if only donations with undetectable anti-HBs were infectious. For 279 components in the lookback study, no traced recipients were HBsAg-positive and 7 recipients were anti-HBc-reactive in association with 4 donors, 3 of whom had an anti-HBs level of more than 100 mIU per mL and 1 of whom had a level of 61 mIU per mL. Implementation of anti-HBc screening reduced the risk of transfusing potentially infectious units by at least as much as had been expected based on the literature. The lookback did not provide proof of transfusion transmission of HBV from HBV DNA-positive, anti-HBc-reactive, HBsAg-negative donors but it did not establish lack of transmission either.
Aguirre, José A; Märzendorfer, Olivia; Brada, Muriel; Saporito, Andrea; Borgeat, Alain; Bühler, Philipp
2016-12-01
Beach chair position is considered a potential risk factor for central neurological events particularly if combined with low blood pressure. The aim of this study was to assess the impact of regional anesthesia on cerebral blood flow and neurobehavioral outcome. This is a prospective, assessor-blinded observational study evaluating patients in the beach chair position undergoing shoulder surgery under regional anesthesia. University hospital operating room. Forty patients with American Society of Anesthesiologists classes I-II physical status scheduled for elective shoulder surgery. Cerebral saturation and blood flow of the middle cerebral artery were measured prior to anesthesia and continued after beach chair positioning until discharge to the postanesthesia care unit. The anesthesiologist was blinded for these values. Controlled hypotension with systolic blood pressure≤100mm Hg was maintained during surgery. Neurobehavioral tests and values of regional cerebral saturation, bispectral index, the mean maximal blood flow of the middle cerebral artery, and invasive blood pressure were measured prior to regional anesthesia, and measurements were repeated after placement of the patient on the beach chair position and every 20 minutes thereafter until discharge to postanesthesia care unit. The neurobehavioral tests were repeated the day after surgery. The incidence of cerebral desaturation events was 5%. All patients had a significant blood pressure drop 5 minutes after beach chair positioning, measured at the heart as well as the acoustic meatus levels, when compared with baseline values (P<.05). There was no decrease in either the regional cerebral saturation (P=.136) or the maximal blood flow of the middle cerebral artery (P=.212) at the same time points. Some neurocognitive tests showed an impairment 24 hours after surgery (P<.001 for 2 of 3 tests). Beach chair position in patients undergoing regional anesthesia for shoulder surgery had no major impact on cerebral blood flow and cerebral oxygenation. However, some impact on neurobehavioral outcome 24 hours after surgery was observed. Copyright © 2016 Elsevier Inc. All rights reserved.
Characteristics of HIV-Positive Transgender Men Receiving Medical Care: United States, 2009–2014
Lemons, Ansley; Beer, Linda; Finlayson, Teresa; McCree, Donna Hubbard; Lentine, Daniel; Shouse, R. Luke
2017-01-01
Objectives To present the first national estimate of the sociodemographic, clinical, and behavioral characteristics of HIV-positive transgender men receiving medical care in the United States. Methods This analysis included pooled interview and medical record data from the 2009 to 2014 cycles of the Medical Monitoring Project, which used a 3-stage, probability-proportional-to-size sampling methodology. Results Transgender men accounted for 0.16% of all adults and 11% of all transgender adults receiving HIV medical care in the United States from 2009 to 2014. Of these HIV-positive transgender men receiving medical care, approximately 47% lived in poverty, 69% had at least 1 unmet ancillary service need, 23% met criteria for depression, 69% were virally suppressed at their last test, and 60% had sustained viral suppression over the previous 12 months. Conclusions Although they constitute a small proportion of all HIV-positive patients, more than 1 in 10 transgender HIV-positive patients were transgender men. Many experienced socioeconomic challenges, unmet needs for ancillary services, and suboptimal health outcomes. Attention to the challenges facing HIV-positive transgender men may be necessary to achieve the National HIV/AIDS Strategy goals of decreasing disparities and improving health outcomes among transgender persons. PMID:29161069
Protozoal coinfection in horses with equine protozoal myeloencephalitis in the eastern United States
Howe, Daniel; Yeargan, Michelle; Morrow, Jennifer K.; Graves, Amy; Johnson, Amy L.
2018-01-01
Background Infection by 2 or more protozoa is linked with increased severity of disease in marine mammals with protozoan encephalitis. Hypothesis/Objectives To assess whether horses with equine protozoal myeloencephalitis (EPM) caused by Sarcocystis neurona also have evidence of infection with Neospora hughesi or Toxoplasma gondii. We hypothesized that horses with EPM would be more likely than horses with cervical vertebral stenotic myelopathy (CVSM) to be positive for antibodies to multiple protozoan parasites. Animals One hundred one horses with neurologic disease: 49 with EPM and 52 with CVSM. Methods Case review. Archived serum and cerebrospinal fluid (CSF) from 101 horses were examined. Inclusion criteria included neurologic disease, antemortem or postmortem diagnosis of EPM or CVSM, and availability of serological results or archived samples for testing. Additional testing for antibodies was performed on serum for T. gondii, as well as serum and CSF for N. hughesi. Results Horses with EPM were more likely than horses with CVSM to have positive immunologic results for S. neurona on serum (95.9% versus 76.9%, P = .0058), CSF (98.0% versus 44.2%, P < .00001), and serum : CSF titer ratio (91.8% versus 0%, P < .00001). Positive results for Neospora and Toxoplasma were uncommon, with total seroprevalence rates of 12.9% and 14.9%, respectively. The proportions of EPM cases testing positive for Neospora and Toxoplasma (16% and 12%) were not different from the proportions of CVSM cases testing positive (10% and 17%, P = .31 and .47, respectively). Conclusion Results do not indicate an important role for protozoal coinfection in EPM in the eastern United States. PMID:29633348
β-Lactam Resistance and Enterobacteriaceae, United States
Joyce, Kevin; Fey, Paul D.; Nelson, Jennifer M.; Angulo, Frederick J.; Barrett, Timothy J.
2005-01-01
Extended-spectrum cephalosporins (ESC) are an important drug class for treating severe Salmonella infections. We screened the human collection from the National Antimicrobial Resistance Monitoring System 2000 for ESC resistance mechanisms. Of non-Typhi Salmonella tested, 3.2% (44/1,378) contained blaCMY genes. Novel findings included blaCMY-positive Escherichia coli O157:H7 and a blaSHV-positive Salmonella isolate. CMY-positive isolates showed a ceftriaxone MIC >2 µg/mL. PMID:16229784
A configurable electronics system for the ESS-Bilbao beam position monitors
NASA Astrophysics Data System (ADS)
Muguira, L.; Belver, D.; Etxebarria, V.; Varnasseri, S.; Arredondo, I.; del Campo, M.; Echevarria, P.; Garmendia, N.; Feuchtwanger, J.; Jugo, J.; Portilla, J.
2013-09-01
A versatile and configurable system has been developed in order to monitorize the beam position and to meet all the requirements of the future ESS-Bilbao Linac. At the same time the design has been conceived to be open and configurable so that it could eventually be used in different kinds of accelerators, independent of the charged particle, with minimal change. The design of the Beam Position Monitors (BPMs) system includes a test bench both for button-type pick-ups (PU) and striplines (SL), the electronic units and the control system. The electronic units consist of two main parts. The first part is an Analog Front-End (AFE) unit where the RF signals are filtered, conditioned and converted to base-band. The second part is a Digital Front-End (DFE) unit which is based on an FPGA board where the base-band signals are sampled in order to calculate the beam position, the amplitude and the phase. To manage the system a Multipurpose Controller (MC) developed at ESSB has been used. It includes the FPGA management, the EPICS integration and Archiver Instances. A description of the system and a comparison between the performance of both PU and SL BPM designs measured with this electronics system are fully described and discussed.
Maluil, Samuel; Stevens, Rom A
2016-11-01
Schistosomiasis is a known risk after exposure to freshwater in tropical parts of the world. In March 2014, 28 off-duty U.S. service members went on a water adventure in the Nile River in Jinja, Uganda. In April 2014, 10 of the 28 service members returned for a second water adventure. Twelve weeks after freshwater exposure, schistosomiasis enzyme-linked immunosorbent assay testing was performed. Twenty-five percent had elevated Schistosomiasis mansoni immunoglobulin G (7 positive of 28 exposed); all had negative pre-exposure serology. The serology-positive service members were treated with oral praziquantel 60 mg/kg in divided doses. Our report is the first schistosomiasis report among U.S. service members deployed to Africa since World War II. The absence of reports among U.S. service members and several reports among deployed foreign military units and tourists in sub-Saharan Africa suggest a lack of postexposure testing. We recommend schistosomiasis testing of prior and future U.S. military units deployed to sub-Saharan Africa with fresh water exposure. Unit commanders and medical personnel should discourage unnecessary fresh water contact in sub-Saharan Africa. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.
NASA Technical Reports Server (NTRS)
Luu, D.
1999-01-01
This is the Performance Verification Report, AMSU-A1 Antenna Drive Subsystem, P/N 1331720-2, S/N 106, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A). The antenna drive subsystem of the METSAT AMSU-A1, S/N 106, P/N 1331720-2, completed acceptance testing per A-ES Test Procedure AE-26002/lD. The test included: Scan Motion and Jitter, Pulse Load Bus Peak Current and Rise Time, Resolver Reading and Position Error, Gain/ Phase Margin, and Operational Gain Margin. The drive motors and electronic circuitry were also tested at the component level. The drive motor test includes: Starting Torque Test, Motor Commutation Test, Resolver Operation/ No-Load Speed Test, and Random Vibration. The electronic circuitry was tested at the Circuit Card Assembly (CCA) level of production; each test exercised all circuit functions. The transistor assembly was tested during the W3 cable assembly (1356941-1) test.
NASA Technical Reports Server (NTRS)
Vallot, Lawrence; Snyder, Scott; Schipper, Brian; Parker, Nigel; Spitzer, Cary
1991-01-01
NASA-Langley has conducted a flight test program evaluating a differential GPS/inertial navigation system's (DGPS/INS) utility as an approach/landing aid. The DGPS/INS airborne and ground components are based on off-the-shelf transport aircraft avionics, namely a global positioning/inertial reference unit (GPIRU) and two GPS sensor units (GPSSUs). Systematic GPS errors are measured by the ground GPSSU and transmitted to the aircraft GPIRU, allowing the errors to be eliminated or greatly reduced in the airborne equipment. Over 120 landings were flown; 36 of these were fully automatic DGPS/INS landings.
Freeman, Arin E; Sullivan, Patrick; Higa, Darrel; Sharma, Akshay; MacGowan, Robin; Hirshfield, Sabina; Greene, George J; Gravens, Laura; Chavez, Pollyanna; McNaghten, A D; Johnson, Wayne D; Mustanski, Brian
2018-02-01
HIV testing is the gateway into both prevention and treatment services. It is important to understand how men who have sex with men (MSM) perceive HIV self-tests. We conducted focus groups and individual interviews to collect feedback on two HIV self-tests, and on a dried blood spot (DBS) specimen collection kit. Perceptions and attitudes around HIV self-testing (HIVST), and willingness to distribute HIV self-tests to others were assessed. MSM reported HIVST to be complementary to facility-based testing, and liked this approach because it offers privacy and convenience, does not require counseling, and could lead to linkage to care. However, they also had concerns around the accuracy of HIV self-tests, their cost, and receiving a positive test result without immediate access to follow-up services. Despite these issues, they perceived HIVST as a positive addition to their HIV prevention toolbox.
Spence Laschinger, Heather K; Nosko, Amanda; Wilk, Piotr; Finegan, Joan
2014-12-01
Recruitment and retention strategies have emphasized the importance of positive work environments that support professional nursing practice for sustaining the nursing workforce. Unit leadership that creates empowering workplace conditions plays a key role in establishing supportive practice environments that increase work effectiveness, and, ultimately, improves job satisfaction. To test a multi-level model examining the effect of both contextual and individual factors on individual nurse job satisfaction. At the unit level, structural empowerment and support for professional nursing practice (organizational resources) were hypothesized to be predictors of unit level effectiveness. At the individual level, core self-evaluation, and psychological empowerment (intrapersonal resources) were modeled as predictors of nurse job satisfaction one year later. Cross-level unit effects on individual nurses' job satisfaction were also examined. This study employed a longitudinal survey design with 545 staff nurses from 49 hospital units in Ontario, Canada. Participants completed a survey at two points in time (response rate of 40%) with standardized measures of the major study variables in the hypothesized model. Multilevel structural equation modeling was used to test the model. Nurses shared perceptions of structural empowerment on their units indirectly influenced their shared perceptions of unit effectiveness (Level 2) through perceived unit support for professional nursing practice, which in turn, had a significant positive direct effect on unit effectiveness (Level 2). Unit effectiveness was also strongly related to individual nurse job satisfaction one year later. At Level 1, higher core self-evaluation had a direct and indirect effect on job satisfaction through increased psychological empowerment. The results suggest that nurses' job satisfaction is influenced by a combination of individual and contextual factors demonstrating utility in considering both sources of nurses' satisfaction with their work in creating effective nursing work environments. Copyright © 2014 Elsevier Ltd. All rights reserved.
Meini, Genny; Dello Russo, Cinzia; Allice, Tiziano; Barresi, Renata; D'Arrigo, Roberta; Falasca, Francesca; Lipsi, Maria Rosaria; Paolucci, Stefania; Zanussi, Stefania; Antonetti, Raffaele; Baldanti, Fausto; Basaglia, Giancarlo; Bruzzone, Bianca; Polilli, Ennio; Ghisetti, Valeria; Pucillo, Leopoldo Paolo; Turriziani, Ombretta; Pirazzoli, Antonella; Navarra, Pierluigi; Zazzi, Maurizio
2016-05-01
Since the HLA-B*57:01 allele is strongly associated with abacavir hypersensitivity reaction, testing for the presence of HLA-B*57:01 is mandatory before administration of abacavir. While HLA-B*57:01 testing is usually provided by pharmacogenetics, genetics or blood transfusion services, clinical virology laboratories can be an optimal opportunity for HLA-B*57:01 testing since they receive blood samples for routine HIV monitoring and have the expertise for convenient and less expensive PCR-based point mutation assays. The Italian HLA-B*57:01 Network gathers accredited clinical virology laboratories offering HLA-B*57:01 testing in Italy with the aim to share protocols, test new methods, develop and maintain external quality assurance (EQA) programs. A panel of 9HLA-B*57:01-positive and 16HLA-B*57:01-negative frozen blood samples were blindly distributed to 10 units including 9 clinical virology laboratories and one reference pharmacology laboratory. Each laboratory was free to use its own routine method for DNA extraction and HLA-B*57:01 testing. DNA was extracted by automated workstations in 6 units and by manual spin columns in 4. Eight units used the Duplicα Real Time HLA-B*57:01 kit by Euroclone and two units used two different PCR homemade protocols. All the 10 units correctly identified all the 25 samples. The first HLA-B*57:01 EQA program run in Italy showed that clinical virology units are equipped and proficient for providing HLA-B*57:01 testing by inexpensive assays easy to integrate into their routine. Copyright © 2016 Elsevier B.V. All rights reserved.
Arbes, Samuel J; Gergen, Peter J; Elliott, Leslie; Zeldin, Darryl C
2005-08-01
Allergy skin tests were administered in the second and third National Health and Nutrition Examination Surveys (NHANES II and III) conducted in the United States from 1976 through 1980 and 1988 through 1994, respectively. This study estimated positive skin test response rates in NHANES III and identified predictors of one or more positive test responses. Comparisons with NHANES II were also made. In NHANES III, 10 allergens and 2 controls were tested in all subjects aged 6 to 19 years and a random half-sample of subjects aged 20 to 59 years. A wheal-based definition of a positive test response was used. In NHANES III, 54.3% of the population had positive test responses to 1 or more allergens. Prevalences were 27.5% for dust mite, 26.9% for perennial rye, 26.2% for short ragweed, 26.1% for German cockroach, 18.1% for Bermuda grass, 17.0% for cat, 15.2% for Russian thistle, 13.2% for white oak, 12.9% for Alternaria alternata, and 8.6% for peanut. Among those with positive test responses, the median number of positive responses was 3.0. Adjusted odds of a positive test response were higher for the following variables: age of 20 to 29 years, male sex, minority race, western region, old homes, and lower serum cotinine levels. For the 6 allergens common to NHANES II and III, prevalences were 2.1 to 5.5 times higher in NHANES III. The majority of the US population represented in NHANES III was sensitized to 1 or more allergens. Whether the higher prevalences observed in NHANES III reflect true changes in prevalence or methodological differences between the surveys cannot be determined with certainty.
Antibody against infectious salmon anaemia virus among feral Atlantic salmon (Salmo salar)
Cipriano, R.C.
2009-01-01
Archived sera from Atlantic salmon (Salmo salar) that returned to the Penobscot River (Maine), Merrimack River (Massachusetts), and Connecticut River (in Massachusetts) from 1995 to 2002 were analysed for antibodies against infectious salmon anaemia virus (ISAV) using an enzyme-linked immunosorbent assay (ELISA). Up to 60 samples were archived per river system per year. In a given year, the number of fish sampled by ELISA for ISAV antibodies in the Penobscot River ranged from 2.9 to 11.2, and the range of salmon sampled in the Merrimack River and the Connecticut River was 31.3-100 and 20.0-67.5, respectively. Archived sera were not available for the 1995 and 2002 year classes from the Connecticut River. In all, 1141 samples were processed; 14 serum samples tested positive for antibodies to ISAV. In the Penobscot River, serum from one fish tested positive in each of the 1995 and 1999 year-class returns, and sera from two fish tested positive in the 1998 returns. In the Merrimack River, sera from four fish tested positive in each of the 1996 and 1997 returns, and sera from two fish were positive in the 2002 return. None of the archived sera from Atlantic salmon that returned to the Connecticut River tested positive. ?? 2009 United States Government, Department of the Interior.
Chuke, Stella O; Yen, Nguyen Thi Ngoc; Laserson, Kayla F; Phuoc, Nguyen Huu; Trinh, Nguyen An; Nhung, Duong Thi Cam; Mai, Vo Thi Chi; Qui, An Dang; Hai, Hoang Hoa; Loan, Le Thien Huong; Jones, Warren G; Whitworth, William C; Shah, J Jina; Painter, John A; Mazurek, Gerald H; Maloney, Susan A
2014-01-01
Objective. Use of tuberculin skin tests (TSTs) and interferon gamma release assays (IGRAs) as part of tuberculosis (TB) screening among immigrants from high TB-burden countries has not been fully evaluated. Methods. Prevalence of Mycobacterium tuberculosis infection (MTBI) based on TST, or the QuantiFERON-TB Gold test (QFT-G), was determined among immigrant applicants in Vietnam bound for the United States (US); factors associated with test results and discordance were assessed; predictive values of TST and QFT-G for identifying chest radiographs (CXRs) consistent with TB were calculated. Results. Of 1,246 immigrant visa applicants studied, 57.9% were TST positive, 28.3% were QFT-G positive, and test agreement was 59.4%. Increasing age was associated with positive TST results, positive QFT-G results, TST-positive but QFT-G-negative discordance, and abnormal CXRs consistent with TB. Positive predictive values of TST and QFT-G for an abnormal CXR were 25.9% and 25.6%, respectively. Conclusion. The estimated prevalence of MTBI among US-bound visa applicants in Vietnam based on TST was twice that based on QFT-G, and 14 times higher than a TST-based estimate of MTBI prevalence reported for the general US population in 2000. QFT-G was not better than TST at predicting abnormal CXRs consistent with TB.
Ong, K J; Thornton, A C; Fisher, M; Hutt, R; Nicholson, S; Palfreeman, A; Perry, N; Stedman-Bryce, G; Wilkinson, P; Delpech, V; Nardone, A
2016-04-01
Following national guidelines to expand HIV testing in high-prevalence areas in England, a number of pilot studies were conducted in acute general medical admission units (ACUs) and general practices (GPs) to assess the feasibility and acceptability of testing in these settings. The aim of this study was to estimate the cost per HIV infection diagnosed through routine HIV testing in these settings. Resource use data from four 2009/2010 Department of Health pilot studies (two ACUs; two GPs) were analysed. Data from the pilots were validated and supplemented with information from other sources. We constructed possible scenarios to estimate the cost per test carried out through expanded HIV testing in ACUs and GPs, and the cost per diagnosis. In the pilots, cost per test ranged from £8.55 to £13.50, and offer time and patient uptake were 2 minutes and 90% in ACUs, and 5 minutes and 60% in GPs, respectively. In scenario analyses we fixed offer time, diagnostic test cost and uptake rate at 2 minutes, £6 and 80% for ACUs, and 5 minutes, £9.60 and 40% for GPs, respectively. The cost per new HIV diagnosis at a positivity of 2/1000 tests conducted was £3230 in ACUs and £7930 in GPs for tests performed by a Band 3 staff member, and £5940 in ACUs and £18 800 in GPs for tests performed by either hospital consultants or GPs. Expanded HIV testing may be more cost-efficient in ACUs than in GPs as a consequence of a shorter offer time, higher patient uptake, higher HIV positivity and lower diagnostic test costs. As cost per new HIV diagnosis reduces at higher HIV positivity, expanded HIV testing should be promoted in high HIV prevalence areas. © 2015 British HIV Association.
A pressure-packer system for conducting rising head tests in water table wells
Levy, Benjamin S.; Pannell, Lawrence J.; Dadoly, John P.
1993-01-01
The pressure system developed for fully-saturated well screens has been modified for conducting rising head tests in water table wells installed in highly permeable aquifers. The pressure system consists of a compressed air source and 1 inch diameter PVC piping with a packer attached at the end. The pressure system was evaluated in a series of rising head tests conducted in a well at a Superfund site in New England. The well was tested with slugs and with the pressure system. Within each technique, estimates of hydraulic conductivity showed no difference. Comparison of hydraulic conductivity estimates between techniques (slug test vs. pressure test) showed differences due to stratigraphy. The interval tested using slug tests crossed two stratigraphic units; the pressure system tested only one of these units. We conclude that the pressure system may be used to characterize the vertical hydraulic conductivity distribution in a series of successive tests by changing the packer position and the screened interval tested.
SU-D-201-04: Evaluation of Elekta Agility MLC Performance Using Statistical Process Control
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meyers, SM; Balderson, MJ; Letourneau, D
2016-06-15
Purpose: to evaluate the performance and stability of the Elekta Agility MLC model using an automated quality control (QC) test in combination with statistical process control tools. Methods: Leaf positions were collected daily for 11 Elekta units over 5–19 months using the automated QC test, which analyzes 23 MV images to determine the location of MLC leaves relative to the radiation isocenter. The leaf positions are measured at 5 nominal positions, and images are acquired at collimator 0° and 180° to capture all MLC leaves in the field-of-view. Leaf positioning accuracy was assessed using individual and moving range control charts.more » Control limits were recomputed following MLC recalibration (occurred 1–2 times for 4 units). Specification levels of ±0.5, ±1 and ±1.5mm were tested. The mean and range of duration between out-of-control and out-of-specification events were determined. Results: Leaf position varied little over time, as confirmed by very tight individual control limits (mean ±0.19mm, range 0.09–0.44). Mean leaf position error was −0.03mm (range −0.89–0.83). Due to sporadic out-of-control events, the mean in-control duration was 3.3 days (range 1–23). Data stayed within ±1mm specification for 205 days on average (range 3–372) and within ±1.5mm for the entire date range. Measurements stayed within ±0.5mm for 1 day on average (range 0–17); however, our MLC leaves were not calibrated to this level of accuracy. Conclusion: The Elekta Agility MLC model was found to perform with high stability, as evidenced by the tight control limits. The in-specification durations support the current recommendation of monthly MLC QC tests with a ±1mm tolerance. Future work is on-going to determine if Agility performance can be optimized further using high-frequency QC test results to drive recalibration frequency. Factors that can affect leaf positioning accuracy, including beam spot motion, leaf gain calibration, drifting leaves, and image artifacts, are under investigation.« less
Context matters: the impact of unit leadership and empowerment on nurses' organizational commitment.
Laschinger, Heather K Spence; Finegan, Joan; Wilk, Piotr
2009-05-01
The aim of this study was to test a multilevel model linking unit-level leader-member exchange quality and structural empowerment to nurses' psychological empowerment and organizational commitment at the individual level of analysis. Few studies have examined the contextual effects of unit leadership on individual nurse outcomes. Workplace empowerment has been related to retention outcomes such as organizational commitment in several studies, but few have studied the impact of specific unit characteristics within which nurses work on these outcomes. We surveyed 3,156 nurses in 217 hospital units to test the multilevel model. A multilevel path analysis revealed significant individual and contextual effects on nurses' organizational commitment. Both unit-level leader-member exchange quality and structural empowerment had significant direct effects on individual-level psychological empowerment and organizational commitment. Psychological empowerment mediated the relationship between core self-evaluations and organizational commitment at the individual level of analysis. The contextual effects of positive supervisor relationships and their influence on empowering working conditions at the unit level and, subsequently, nurses' organizational commitment highlight the importance of leadership for creating conditions that result in a committed nursing workforce.
Portable light source unit for simulating fires having an adjustable aperture
NASA Technical Reports Server (NTRS)
Youngquist, Robert C. (Inventor); Moerk, John S. (Inventor); Strobel, James P. (Inventor)
1997-01-01
A portable, hand held light source unit is employed to check operation of fire detectors, such as hydrogen fire detectors. The unit emits radiation in a narrow band of wavelengths which are generated by the type of fire to be tested, but not by other light sources such as the sun or incandescent lamps. The unit can test fire detectors at different distances, and of different sensitivities. The intensity of the radiation emitted by the unit is adjustable for this purpose by means of a rotatable disk having a plurality of different sized apertures for selective placement between the light source and an output lens. The disk can also be rotated to a calibration position which causes a microprocessor circuit in the unit to initiate a calibration procedure. During this procedure, the lamp intensity is measured by a photodetector contained within the unit, and the microprocessor adjusts the lamp current to insure that its intensity remains within a preset range of values. A green and a red LED are mounted on the unit which indicate to an operator whether the calibration is successful, as well as the condition of the unit's battery power supply.
Chiodini, P L; Hartley, S; Hewitt, P E; Barbara, J A; Lalloo, K; Bligh, J; Voller, A
1997-01-01
Blood donations are often wasted for lack of a satisfactory procedure to evaluate donors potentially exposed to malaria. We evaluated a commercial ELISA for the detection of antibodies to malaria and compared it with an immunofluorescent antibody test (IFAT). When 5,311 sera from routine non-exposed donors were tested, 24 (0.45%) were positive by the ELISA, using a Plasmodium falciparum antigen. Seventeen were subjected to confirmatory testing but none were positive by IFAT. Of 1,000 donors potentially exposed in endemic areas 15 (1.5%) were repeatably reactive by ELISA. 10 of these were tested by IFAT and 2 were positive. When 150 patients attending the Hospital for Tropical Diseases in London with acute malaria were tested, 73% of those infected with P. falciparum were repeatably reactive for malarial antibodies by ELISA and 56% with Plasmodium vivax. Of 88 stored clinical sera tested by both IFAT and ELISA 56 were positive by IFAT and of these 52 (93 degrees/0) were positive by ELISA. The ELISA is sufficiently sensitive and specific to screen at-risk donors. Its use could safely retrieve 40,000 red cell units currently discarded each year in Great Britain.
Reimschuessel, Renate; Grabenstein, Michael; Guag, Jake; Nemser, Sarah M; Song, Kyunghee; Qiu, Junshan; Clothier, Kristin A; Byrne, Barbara A; Marks, Stanley L; Cadmus, Kyran; Pabilonia, Kristy; Sanchez, Susan; Rajeev, Sreekumari; Ensley, Steve; Frana, Timothy S; Jergens, Albert E; Chappell, Kimberly H; Thakur, Siddhartha; Byrum, Beverly; Cui, Jing; Zhang, Yan; Erdman, Matthew M; Rankin, Shelley C; Daly, Russell; Das, Seema; Ruesch, Laura; Lawhon, Sara D; Zhang, Shuping; Baszler, Timothy; Diaz-Campos, Dubraska; Hartmann, Faye; Okwumabua, Ogi
2017-05-01
Eleven laboratories collaborated to determine the periodic prevalence of Salmonella in a population of dogs and cats in the United States visiting veterinary clinics. Fecal samples (2,965) solicited from 11 geographically dispersed veterinary testing laboratories were collected in 36 states between January 2012 and April 2014 and tested using a harmonized method. The overall study prevalence of Salmonella in cats (3 of 542) was <1%. The prevalence in dogs (60 of 2,422) was 2.5%. Diarrhea was present in only 55% of positive dogs; however, 3.8% of the all diarrheic dogs were positive, compared with 1.8% of the nondiarrheic dogs. Salmonella -positive dogs were significantly more likely to have consumed raw food ( P = 0.01), to have consumed probiotics ( P = 0.002), or to have been given antibiotics ( P = 0.01). Rural dogs were also more likely to be Salmonella positive than urban ( P = 0.002) or suburban ( P = 0.001) dogs. In the 67 isolates, 27 unique serovars were identified, with three dogs having two serovars present. Antimicrobial susceptibility testing of 66 isolates revealed that only four of the isolates were resistant to one or more antibiotics. Additional characterization of the 66 isolates was done using pulsed-field gel electrophoresis and whole-genome sequencing (WGS). Sequence data compared well to resistance phenotypic data and were submitted to the National Center for Biotechnology Information (NCBI). This study suggests an overall decline in prevalence of Salmonella -positive dogs and cats over the last decades and identifies consumption of raw food as a major risk factor for Salmonella infection. Of note is that almost half of the Salmonella -positive animals were clinically nondiarrheic. Copyright © 2017 Reimschuessel et al.
Grabenstein, Michael; Guag, Jake; Nemser, Sarah M.; Song, Kyunghee; Qiu, Junshan; Clothier, Kristin A.; Byrne, Barbara A.; Marks, Stanley L.; Cadmus, Kyran; Pabilonia, Kristy; Sanchez, Susan; Rajeev, Sreekumari; Ensley, Steve; Frana, Timothy S.; Jergens, Albert E.; Chappell, Kimberly H.; Thakur, Siddhartha; Byrum, Beverly; Cui, Jing; Zhang, Yan; Erdman, Matthew M.; Rankin, Shelley C.; Daly, Russell; Das, Seema; Ruesch, Laura; Zhang, Shuping; Baszler, Timothy; Diaz-Campos, Dubraska; Hartmann, Faye; Okwumabua, Ogi
2017-01-01
ABSTRACT Eleven laboratories collaborated to determine the periodic prevalence of Salmonella in a population of dogs and cats in the United States visiting veterinary clinics. Fecal samples (2,965) solicited from 11 geographically dispersed veterinary testing laboratories were collected in 36 states between January 2012 and April 2014 and tested using a harmonized method. The overall study prevalence of Salmonella in cats (3 of 542) was <1%. The prevalence in dogs (60 of 2,422) was 2.5%. Diarrhea was present in only 55% of positive dogs; however, 3.8% of the all diarrheic dogs were positive, compared with 1.8% of the nondiarrheic dogs. Salmonella-positive dogs were significantly more likely to have consumed raw food (P = 0.01), to have consumed probiotics (P = 0.002), or to have been given antibiotics (P = 0.01). Rural dogs were also more likely to be Salmonella positive than urban (P = 0.002) or suburban (P = 0.001) dogs. In the 67 isolates, 27 unique serovars were identified, with three dogs having two serovars present. Antimicrobial susceptibility testing of 66 isolates revealed that only four of the isolates were resistant to one or more antibiotics. Additional characterization of the 66 isolates was done using pulsed-field gel electrophoresis and whole-genome sequencing (WGS). Sequence data compared well to resistance phenotypic data and were submitted to the National Center for Biotechnology Information (NCBI). This study suggests an overall decline in prevalence of Salmonella-positive dogs and cats over the last decades and identifies consumption of raw food as a major risk factor for Salmonella infection. Of note is that almost half of the Salmonella-positive animals were clinically nondiarrheic. PMID:28202802
Zhang, Yongquan; Tang, Huiming; Li, Changdong; Lu, Guiying; Cai, Yi; Zhang, Junrong; Tan, Fulin
2018-01-14
The physical model test of landslides is important for studying landslide structural damage, and parameter measurement is key in this process. To meet the measurement requirements for deep displacement in landslide physical models, an automatic flexible inclinometer probe with good coupling and large deformation capacity was designed. The flexible inclinometer probe consists of several gravity acceleration sensing units that are protected and positioned by silicon encapsulation, all the units are connected to a 485-comunication bus. By sensing the two-axis tilt angle, the direction and magnitude of the displacement for a measurement unit can be calculated, then the overall displacement is accumulated according to all units, integrated from bottom to top in turn. In the conversion from angle to displacement, two spline interpolation methods are introduced to correct and resample the data; one is to interpolate the displacement after conversion, and the other is to interpolate the angle before conversion; compared with the result read from checkered paper, the latter is proved to have a better effect, with an additional condition that the displacement curve move up half the length of the unit. The flexible inclinometer is verified with respect to its principle and arrangement by a laboratory physical model test, and the test results are highly consistent with the actual deformation of the landslide model.
Zhang, Yongquan; Tang, Huiming; Li, Changdong; Lu, Guiying; Cai, Yi; Zhang, Junrong; Tan, Fulin
2018-01-01
The physical model test of landslides is important for studying landslide structural damage, and parameter measurement is key in this process. To meet the measurement requirements for deep displacement in landslide physical models, an automatic flexible inclinometer probe with good coupling and large deformation capacity was designed. The flexible inclinometer probe consists of several gravity acceleration sensing units that are protected and positioned by silicon encapsulation, all the units are connected to a 485-comunication bus. By sensing the two-axis tilt angle, the direction and magnitude of the displacement for a measurement unit can be calculated, then the overall displacement is accumulated according to all units, integrated from bottom to top in turn. In the conversion from angle to displacement, two spline interpolation methods are introduced to correct and resample the data; one is to interpolate the displacement after conversion, and the other is to interpolate the angle before conversion; compared with the result read from checkered paper, the latter is proved to have a better effect, with an additional condition that the displacement curve move up half the length of the unit. The flexible inclinometer is verified with respect to its principle and arrangement by a laboratory physical model test, and the test results are highly consistent with the actual deformation of the landslide model. PMID:29342902
Bastida Castillo, Alejandro; Gómez Carmona, Carlos D; De la Cruz Sánchez, Ernesto; Pino Ortega, José
2018-05-01
There is interest in the accuracy and inter-unit reliability of position-tracking systems to monitor players. Research into this technology, although relatively recent, has grown exponentially in the last years, and it is difficult to find professional team sport that does not use Global Positioning System (GPS) technology at least. The aim of this study is to know the accuracy of both GPS-based and Ultra Wide Band (UWB)-based systems on a soccer field and their inter- and intra-unit reliability. A secondary aim is to compare them for practical applications in sport science. Following institutional ethical approval and familiarization, 10 healthy and well-trained former soccer players (20 ± 1.6 years, 1.76 ± 0.08 cm, and 69.5 ± 9.8 kg) performed three course tests: (i) linear course, (ii) circular course, and (iii) a zig-zag course, all using UWB and GPS technologies. The average speed and distance covered were compared with timing gates and the real distance as references. The UWB technology showed better accuracy (bias: 0.57-5.85%), test-retest reliability (%TEM: 1.19), and inter-unit reliability (bias: 0.18) in determining distance covered than the GPS technology (bias: 0.69-6.05%; %TEM: 1.47; bias: 0.25) overall. Also, UWB showed better results (bias: 0.09; ICC: 0.979; bias: 0.01) for mean velocity measurement than GPS (bias: 0.18; ICC: 0.951; bias: 0.03).
Visible light communication and indoor positioning using a-SiCH device as receiver
NASA Astrophysics Data System (ADS)
Vieira, M. A.; Vieira, M.; Louro, P.; Vieira, P.; Fantoni, A.
2017-08-01
An indoor positioning system were trichromatic white LEDs are used both for illumination proposes and as transmitters and an optical processor, based on a-SiC:H technology, as mobile receiver is presented. OOK modulation scheme is used, and it provides a good trade-off between system performance and implementation complexity. The relationship between the transmitted data and the received digital output levels is decoded. The system topology for positioning is a self-positioning system in which the measuring unit is mobile. This unit receives the signals of several transmitters in known locations, and has the capability to compute its location based on the measured signals. LED bulbs work as transmitters, sending information together with different IDs related to their physical locations. A triangular topology for the unit cell is analysed. A 2D localization design, demonstrated by a prototype implementation is presented. Fine-grained indoor localization is tested. The received signal is used in coded multiplexing techniques for supporting communications and navigation concomitantly on the same channel. The position is estimated through the visible multilateration metodh using several non-collinear transmitters. The location and motion information is found by mapping position and estimates the location areas. Data analysis showed that by using a pinpin double photodiode based on a a-SiC:H heterostucture as receiver, and RBGLEDs as transmitters it is possible not only to determine the mobile target's position but also to infer the motion direction over time, along with the received information in each position.
Miyazawa, Tokuo; Imai, Takanori; Itabashi, Kazuo
2016-01-01
To assess predictors of positive oral food challenge test (OFC) in neonates that are suggestive of gastrointestinal food allergy. A prospective case accumulations study on neonates suspected of having gastrointestinal food allergy was conducted in 126 neonatal intensive care units in Japan between April 2010 and September 2011. Neonates who underwent an OFC for the diagnosis of gastrointestinal food allergy were enrolled. Clinical backgrounds, clinical symptoms, and laboratory findings were compared between neonates with a positive OFC and those with a negative OFC. An analysis was performed in 32 neonates. The OFC results were positive in 9 neonates (28.1%), pseudo-positive in 4, and negative in 19. There were no significant differences in clinical backgrounds between the positive OFC group and the negative OFC group. Vomiting and bloody stool were frequently observed in both groups (approximately 70%), although there were no significant differences in the clinical symptoms between the two groups. Additional diagnostic tests included those for eosinophils in the peripheral blood and stool mucus and allergen-specific lymphocyte stimulation test. There were no significant differences in laboratory findings between the two groups, and many neonates showed pseudo-positive in all of the tests. It was difficult to predict OFC results based on clinical symptoms and additional diagnostic test results. In order to obtain an accurate diagnosis of gastrointestinal food allergy in neonates, OFC should be performed proactively under conditions that enable complete understanding of risks to neonates.
Spectrum Management Guidelines for National and Service Test and Training Ranges
2017-07-12
GPS Global Positioning System ISM Installation Spectrum Manager JTIDS Joint Tactical Information Distribution System KMR Kwajalein Missile Range... information UAV unmanned aerial vehicle US&P United States and Possessions Spectrum Management Guidelines for National and Service Test and Training...frequency deconfliction processes. The AFC will inform the range or center commander and the Installation Spectrum Manager (ISM) at the
Application of an In-Line Contamination Monitoring Unit to the AHT-64 Hydraulic Test Stand.
1981-06-04
suction return connection port will require the operator to secuire same from a squatting position. The present stowage arrangement on the test stand... SPC FC sample~~~ Iepal" -a *Tpoa _______Rate 7 eo3,t Sq,’ TPc owe te - U Enciosure ULeeds & Northrup N’AFC- 92- 1 0 Typical Plumbing Connections for
Is there a third way? A response to Giddens's the Third Way.
Navarro, V
1999-01-01
Since the early 1990s, there has been in the United Kingdom and the United States a new political position referred to as the Third Way that claims to be intermediate between neoliberalism and social democracy, transcending both. This new position represented by the Clinton administration in the United States and the Blair Government in the United Kingdom, assumes that both social democracy and neoliberalism are obsolete and calls instead for a new set of public policies that are defined as the Third Way. This article analyzes the most detailed account of the Third Way in the English-speaking world, written by Professor Giddens. It shows that Giddens stereotypes both the neoliberal and the social democratic positions to an unrecognizable degree, failing to portray the varieties of social democratic policies in existence today in developed capitalist countries. The author shows how the Third Way is merely a recycling of liberal positions in some social policy areas and Christian democratic positions in others. Where the Third Way intends to be innovative--as in the U.K. New Deal program--the programs are pale copies of successful labor market policies carried out by northern European social democratic parties. The author concludes that the Third Way, with its questioning of the universalistic welfare state and its preference for assistential and means-tested programs, signifies a break with the social democratic tradition, transforming it into a hybrid between Christian democracy and neoliberalism.
NASA Technical Reports Server (NTRS)
Putkovich, K.
1981-01-01
Initial test results indicated that the Global Positioning System/Time Transfer Unit (GPS/TTU) performed well within the + or - 100 nanosecond range required by the original system specification. Subsequent testing involved the verification of GPS time at the master control site via portable clocks and the acquisition and tracking of as many passes of the space vehicles currently in operation as possible. A description and discussion of the testing, system modifications, test results obtained, and an evaluation of both GPS and the GPS/TTU are presented.
Ferrando, Carlos; Romero, Carolina; Tusman, Gerardo; Suarez-Sipmann, Fernando; Canet, Jaume; Dosdá, Rosa; Valls, Paola; Villena, Abigail; Serralta, Ferran; Jurado, Ana; Carrizo, Juan; Navarro, Jose; Parrilla, Cristina; Romero, Jose E; Pozo, Natividad; Soro, Marina; Villar, Jesús; Belda, Francisco Javier
2017-01-01
Objective To assess the diagnostic accuracy of peripheral capillary oxygen saturation (SpO2) while breathing room air for 5 min (the ‘Air-Test’) in detecting postoperative atelectasis. Design Prospective cohort study. Diagnostic accuracy was assessed by measuring the agreement between the index test and the reference standard CT scan images. Setting Postanaesthetic care unit in a tertiary hospital in Spain. Participants Three hundred and fifty patients from 12 January to 7 February 2015; 170 patients scheduled for surgery under general anaesthesia who were admitted into the postsurgical unit were included. Intervention The Air-Test was performed in conscious extubated patients after a 30 min stabilisation period during which they received supplemental oxygen therapy via a venturi mask. The Air-Test was defined as positive when SpO2 was ≤96% and negative when SpO2 was ≥97%. Arterial blood gases were measured in all patients at the end of the Air-Test. In the subsequent 25 min, the presence of atelectasis was evaluated by performing a CT scan in 59 randomly selected patients. Main outcome measures The primary study outcome was assessment of the accuracy of the Air-Test for detecting postoperative atelectasis compared with the reference standard. The secondary outcome was the incidence of positive Air-Test results. Results The Air-Test diagnosed postoperative atelectasis with an area under the receiver operating characteristic curve of 0.90 (95% CI 0.82 to 0.98) with a sensitivity of 82.6% and a specificity of 87.8%. The presence of atelectasis was confirmed by CT scans in all patients (30/30) with positive and in 5 patients (17%) with negative Air-Test results. Based on the Air-Test, postoperative atelectasis was present in 36% of the patients (62 out of 170). Conclusion The Air-Test may represent an accurate, simple, inexpensive and non-invasive method for diagnosing postoperative atelectasis. Trial Registration NCT02650037. PMID:28554935
Flight representative positive isolation disconnect
NASA Technical Reports Server (NTRS)
Rosener, A. A.; Jonkoniec, T. G.
1977-01-01
Resolutions were developed for each problem encountered and a tradeoff analysis was performed to select a final configuration for a flight representative PID (Positive Isolation Disconnect) that is reduced in size and comparable in weight and pressure drop to the developmental PID. A 6.35 mm (1/4-inch) line size PID was fabricated and tested. The flight representative PID consists of two coupled disconnect halves, each capable of fluid isolation with essentially zero clearance between them for zero leakage upon disconnect half disengagement. An interlocking foolproofing technique prevents uncoupling of disconnect halves prior to fluid isolation. Future development efforts for the Space Shuttle subsystems that would benefit from the use of the positive isolation disconnect are also recommended. Customary units were utilized for principal measurements and calculations with conversion factors being inserted in equations to convert the results to the international system of units.
Toumi, A; Leteneur, S; Gillet, C; Debril, J-F; Decoufour, N; Barbier, F; Jakobi, J M; Simoneau-Buessinger, Emilie
2015-11-01
Many studies have focused on maximum torque exerted by ankle joint muscles during plantar flexion. While strength parameters are typically measured with isokinetic or isolated ankle dynamometers, these devices often present substantial limitations for the measurement of torque because they account for force in only 1 dimension (1D), and the device often constrains the body in a position that augments torque through counter movements. The purposes of this study were to determine the contribution of body position to ankle plantar-flexion torque and to assess the use of 1D and 3D torque sensors. A custom designed 'Booted, Open-Unit, Three dimension, Transportable, Ergometer' (B.O.T.T.E.) was used to quantify plantar flexion in two conditions: (1) when the participant was restrained within the unit (locked-unit) and (2) when the participant's position was independent of the ankle dynamometer (open-unit). Ten young males performed maximal voluntary isometric plantar-flexion contractions using the B.O.T.T.E. in open and locked-unit mechanical configurations. The B.O.T.T.E. was reliable with ICC higher than 0.90, and CV lower than 7 %. The plantar-flexion maximal resultant torque was significantly higher in the locked-unit compared with open-unit configuration (P < 0.001; +61 to +157 %) due to the addition of forces from the body being constrained within the testing device. A 1D compared with 3D torque sensor significantly underestimated the proper capacity of plantar-flexion torque production (P < 0.001; -37 to -60 %). Assessment of plantar-flexion torque should be performed with an open-unit dynamometer mounted with a 3D sensor that is exclusive of accessory muscles but inclusive of all ankle joint movements.
Liu, Jiming; Tao, Li; Xiao, Bo
2011-01-01
Prior research shows that clinical demand and supplier capacity significantly affect the throughput and the wait time within an isolated unit. However, it is doubtful whether characteristics (i.e., demand, capacity, throughput, and wait time) of one unit would affect the wait time of subsequent units on the patient flow process. Focusing on cardiac care, this paper aims to examine the impact of characteristics of the catheterization unit (CU) on the wait time of cardiac surgery unit (SU). This study integrates published data from several sources on characteristics of the CU and SU units in 11 hospitals in Ontario, Canada between 2005 and 2008. It proposes a two-layer wait time model (with each layer representing one unit) to examine the impact of CU's characteristics on the wait time of SU and test the hypotheses using the Partial Least Squares-based Structural Equation Modeling analysis tool. Results show that: (i) wait time of CU has a direct positive impact on wait time of SU (β = 0.330, p < 0.01); (ii) capacity of CU has a direct positive impact on demand of SU (β = 0.644, p < 0.01); (iii) within each unit, there exist significant relationships among different characteristics (except for the effect of throughput on wait time in SU). Characteristics of CU have direct and indirect impacts on wait time of SU. Specifically, demand and wait time of preceding unit are good predictors for wait time of subsequent units. This suggests that considering such cross-unit effects is necessary when alleviating wait time in a health care system. Further, different patient risk profiles may affect wait time in different ways (e.g., positive or negative effects) within SU. This implies that the wait time management should carefully consider the relationship between priority triage and risk stratification, especially for cardiac surgery.
NASA Technical Reports Server (NTRS)
Kenny, Barbara H.; Kascak, Peter E.; Hofmann, Heath; Mackin, Michael; Santiago, Walter; Jansen, Ralph
2001-01-01
This paper describes the flywheel test facility developed at the NASA Glenn Research Center with particular emphasis on the motor drive components and control. A four-pole permanent magnet synchronous machine, suspended on magnetic bearings, is controlled with a field orientation algorithm. A discussion of the estimation of the rotor position and speed from a "once around signal" is given. The elimination of small dc currents by using a concurrent stationary frame current regulator is discussed and demonstrated. Initial experimental results are presented showing the successful operation and control of the unit at speeds up to 20,000 rpm.
Stephenson, Jennifer L.; Maluf, Katrina S.
2011-01-01
The paired motor unit analysis provides in vivo estimates of the magnitude of persistent inward currents (PIC) in human motoneurons by quantifying changes in the firing rate (ΔF) of an earlier recruited (reference) motor unit at the time of recruitment and derecruitment of a later recruited (test) motor unit. This study assessed the variability of ΔF estimates, and quantified the dependence of ΔF on the discharge characteristics of the motor units selected for analysis. ΔF was calculated for 158 pairs of motor units recorded from nine healthy individuals during repeated submaximal contractions of the tibialis anterior muscle. The mean (SD) ΔF was 3.7 (2.5) pps (range −4.2 to 8.9 pps). The median absolute difference in ΔF for the same motor unit pair across trials was 1.8 pps, and the minimal detectable change in ΔF required to exceed measurement error was 4.8 pps. ΔF was positively related to the amount of discharge rate modulation in the reference motor unit (r2=0.335; P<0.001), and inversely related to the rate of increase in discharge rate (r2=0.125; P<0.001). A quadratic function provided the best fit for relations between ΔF and the time between recruitment of the reference and test motor units (r2=0.229, P<0.001), the duration of test motor unit activity (r2=0.110, P<0.001), and the recruitment threshold of the test motor unit (r2=0.237, P<0.001). Physiological and methodological contributions to the variability in ΔF estimates of PIC magnitude are discussed, and selection criteria to reduce these sources of variability are suggested for the paired motor unit analysis. PMID:21459110
Dunbar, Nancy M; Kreuter, Justin D; Marx-Wood, Cynthia R; Dumont, Larry J; Szczepiorkowski, Zbigniew M
2013-10-01
The platelet (PLT) Pan Genera Detection test (PGD) is a rapid bacterial detection system used to screen PLTs for bacterial contamination. We report a single center 46-month experience with secondary screening of apheresis PLTs by PGD testing. Existing testing records of apheresis PLTs screened by PGD from July 2008 to April 2012 were reviewed. All PLT units were initially screened by routine postcollection culture methods. Secondary screening using PGD was performed for indated PLTs on PLT storage Day 4 and for outdated PLTs on Day 8. A total of 8535 apheresis PLTs were available in inventory during the study period. Of these, 5030 (58.9%) were dispensed and transfused before PGD testing and 3505 (41.1%) underwent PGD testing on Day 4. Twenty-five units tested on Day 4 were PGD initial reactive (0.71%). All were confirmed to be false positive by repeat PGD testing in triplicate (n=20) or by confirmatory culture (n=5). An additional 364 units that were PGD nonreactive on Day 4 were approved for transfusion on Day 6 or Day 7 due to urgent clinical need. A total of 371 outdated units underwent repeat PGD testing before discard on Day 8; all were nonreactive. Secondary PGD testing of culture-screened apheresis PLTs results in low yield in a medium-sized transfusion service. Use of PGD testing on Day 4 may allow for extension of the apheresis PLT shelf life to Day 7 for hospitals that face supply constraints. © 2013 American Association of Blood Banks.
Water characteristics associated with the occurrence of Legionella pneumophila in dental units.
Zanetti, F; Stampi, S; De Luca, G; Fateh-Moghadam, P; Antonietta, M; Sabattini, B; Checchi, L
2000-02-01
This study evaluated the incidence of Legionella pneumophila in dental unit water samples and investigated how the occurrence of these bacteria may be related to some physical, chemical and bacteriological characteristics of the water. The samples were taken from the incoming tap water, oral rinsing cup, air-water syringe, ultrasonic scaler, and the turbine of 23 dental units of private and public institutions. Apart from L. pneumophila (serogroup 1 and 3) isolated in 22 out of the 101 (21.8%) water samples tested, two other species were found: L. bozemanii and L. dumoffii. The highest densities and frequency of L. pneumophila were observed in the water coming into the units and in the dental units of public institutions. A negative association between L. pneumophila and 36 degrees C and 22 degrees C heterotrophic total plate counts and other gram-negative bacteria was found. An inverse association between the concentration of L. pneumophila and water temperature was also observed. The values of pH and total hardness did not show any significant difference in the L. pneumophila-positive and -negative dental unit waters. Finally, the chemical oxygen demand (COD) and residual chlorine were found to correlate positively with L. pneumophila.
Clinical Utility of Testing for Legionella Pneumonia in Central Texas.
Henry, Christopher; Boethel, Carl; Copeland, Laurel A; Ghamande, Shekhar; Arroliga, Alejandro C; White, Heath D
2017-01-01
Legionella pneumophila is an uncommon cause of community-acquired pneumonia in the south central region of the United States, and regular testing may not be cost effective in areas of low incidence. To evaluate the incidence of Legionella in central Texas and to determine the cost effectiveness of Legionella urinary antigen testing. We performed a single-center retrospective cohort study of patients admitted with pneumonia between January 2001 and December 2013. Patients were identified by Binax Legionella urinary antigen and International Classification of Disease, Ninth Revision codes. Demographic characteristics and clinical history of the confirmed Legionella pneumonia cases were obtained by chart review. Descriptive statistics were used to describe patient characteristics. Over 12 years, 5,807 patients with 11,377 admissions for pneumonia were tested for Legionella urinary antigen. A positive Legionella urinary antigen was found in 17 patients. Cumulative incidence during the study period was 0.23%. Among the Legionella-positive patients, intensive care unit admission and median length of stay were 58.8% and 8.5 days, respectively. Most patients (64.7%) met American Thoracic Society criteria for severe pneumonia. All patients empirically received either a macrolide or fluoroquinolone covering Legionella. There were two in-hospital and three total 90-day deaths in those with a positive urinary antigen. The estimated cost of screening this population with Legionella urinary antigen was $214,438 over 13 years. This study reveals the low incidence of Legionella pneumonia in central Texas. Use of guideline-concordant antibiotic treatment provides coverage for Legionella. We speculate that testing in a low-prevalence area would not influence outcomes or be cost effective.
Operational field evaluation of the PAC-MAG man-portable magnetometer array
NASA Astrophysics Data System (ADS)
Keranen, Joe; Topolosky, Zeke; Schultz, Gregory; Miller, Jonathan
2013-06-01
Detection and discrimination of unexploded ordnance (UXO) in areas of prior conflict is of high importance to the international community and the United States government. For humanitarian applications, sensors and processing methods need to be robust, reliable, and easy to train and implement using indigenous UXO removal personnel. This paper describes system characterization, system testing, and a continental United States (CONUS) Operational Field Evaluations (OFE) of the PAC-MAG man-portable UXO detection system. System testing occurred at a government test facility in June, 2010 and December, 2011 and the OFE occurred at the same location in June, 2012. NVESD and White River Technologies personnel were present for all testing and evaluation. The PAC-MAG system is a manportable magnetometer array for the detection and characterization of ferrous UXO. System hardware includes four Cesium vapor magnetometers for detection, a Real-time Kinematic Global Position System (RTK-GPS) for sensor positioning, an electronics module for merging array data and WiFi communications and a tablet computer for transmitting and logging data. An odometer, or "hipchain" encoder, provides position information in GPS-denied areas. System software elements include data logging software and post-processing software for detection and characterization of ferrous anomalies. The output of the post-processing software is a dig list containing locations of potential UXO(s), formatted for import into the system GPS equipment for reacquisition of anomalies. Results from system characterization and the OFE will be described.
Moschetti, Karine; Muzzarelli, Stefano; Pinget, Christophe; Wagner, Anja; Pilz, Günther; Wasserfallen, Jean-Blaise; Schulz-Menger, Jeanette; Nothnagel, Detle; Dill, Torsten; Frank, Herbert; Lombardi, Massimo; Bruder, Oliver; Mahrholdt, Heiko; Schwitter, Jürg
2012-06-14
Cardiovascular magnetic resonance (CMR) has favorable characteristics for diagnostic evaluation and risk stratification of patients with known or suspected CAD. CMR utilization in CAD detection is growing fast. However, data on its cost-effectiveness are scarce. The goal of this study is to compare the costs of two strategies for detection of significant coronary artery stenoses in patients with suspected coronary artery disease (CAD): 1) Performing CMR first to assess myocardial ischemia and/or infarct scar before referring positive patients (defined as presence of ischemia and/or infarct scar to coronary angiography (CXA) versus 2) a hypothetical CXA performed in all patients as a single test to detect CAD. A subgroup of the European CMR pilot registry was used including 2,717 consecutive patients who underwent stress-CMR. From these patients, 21% were positive for CAD (ischemia and/or infarct scar), 73% negative, and 6% uncertain and underwent additional testing. The diagnostic costs were evaluated using invoicing costs of each test performed. Costs analysis was performed from a health care payer perspective in German, United Kingdom, Swiss, and United States health care settings. In the public sectors of the German, United Kingdom, and Swiss health care systems, cost savings from the CMR-driven strategy were 50%, 25% and 23%, respectively, versus outpatient CXA. If CXA was carried out as an inpatient procedure, cost savings were 46%, 50% and 48%, respectively. In the United States context, cost savings were 51% when compared with inpatient CXA, but higher for CMR by 8% versus outpatient CXA. This analysis suggests that from an economic perspective, the use of CMR should be encouraged as a management option for patients with suspected CAD.
Chuke, Stella O.; Yen, Nguyen Thi Ngoc; Laserson, Kayla F.; Phuoc, Nguyen Huu; Trinh, Nguyen An; Nhung, Duong Thi Cam; Mai, Vo Thi Chi; Qui, An Dang; Hai, Hoang Hoa; Loan, Le Thien Huong; Jones, Warren G.; Whitworth, William C.; Shah, J. Jina; Painter, John A.; Mazurek, Gerald H.; Maloney, Susan A.
2014-01-01
Objective. Use of tuberculin skin tests (TSTs) and interferon gamma release assays (IGRAs) as part of tuberculosis (TB) screening among immigrants from high TB-burden countries has not been fully evaluated. Methods. Prevalence of Mycobacterium tuberculosis infection (MTBI) based on TST, or the QuantiFERON-TB Gold test (QFT-G), was determined among immigrant applicants in Vietnam bound for the United States (US); factors associated with test results and discordance were assessed; predictive values of TST and QFT-G for identifying chest radiographs (CXRs) consistent with TB were calculated. Results. Of 1,246 immigrant visa applicants studied, 57.9% were TST positive, 28.3% were QFT-G positive, and test agreement was 59.4%. Increasing age was associated with positive TST results, positive QFT-G results, TST-positive but QFT-G-negative discordance, and abnormal CXRs consistent with TB. Positive predictive values of TST and QFT-G for an abnormal CXR were 25.9% and 25.6%, respectively. Conclusion. The estimated prevalence of MTBI among US-bound visa applicants in Vietnam based on TST was twice that based on QFT-G, and 14 times higher than a TST-based estimate of MTBI prevalence reported for the general US population in 2000. QFT-G was not better than TST at predicting abnormal CXRs consistent with TB. PMID:24738031
40 CFR 204.54 - Test procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., left, front, and back sides and top of the test unit. The microphone position to the right, left, front... calculated by the following method: L=10 log (1/5[Antilog L1/10+Antilog L 2/10+Antilog L 3/10+ Antilog L 4/10+ Antilog L 5/10]) Where: L=The average A-weighted sound level (in decibels) L 1=The A-weighted sound level...
40 CFR 204.54 - Test procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., left, front, and back sides and top of the test unit. The microphone position to the right, left, front... calculated by the following method: L=10 log (1/5[Antilog L1/10+Antilog L 2/10+Antilog L 3/10+ Antilog L 4/10+ Antilog L 5/10]) Where: L=The average A-weighted sound level (in decibels) L 1=The A-weighted sound level...
Mobile HIV screening in Cape Town, South Africa: clinical impact, cost and cost-effectiveness.
Bassett, Ingrid V; Govindasamy, Darshini; Erlwanger, Alison S; Hyle, Emily P; Kranzer, Katharina; van Schaik, Nienke; Noubary, Farzad; Paltiel, A David; Wood, Robin; Walensky, Rochelle P; Losina, Elena; Bekker, Linda-Gail; Freedberg, Kenneth A
2014-01-01
Mobile HIV screening may facilitate early HIV diagnosis. Our objective was to examine the cost-effectiveness of adding a mobile screening unit to current medical facility-based HIV testing in Cape Town, South Africa. We used the Cost Effectiveness of Preventing AIDS Complications International (CEPAC-I) computer simulation model to evaluate two HIV screening strategies in Cape Town: 1) medical facility-based testing (the current standard of care) and 2) addition of a mobile HIV-testing unit intervention in the same community. Baseline input parameters were derived from a Cape Town-based mobile unit that tested 18,870 individuals over 2 years: prevalence of previously undiagnosed HIV (6.6%), mean CD4 count at diagnosis (males 423/µL, females 516/µL), CD4 count-dependent linkage to care rates (males 31%-58%, females 49%-58%), mobile unit intervention cost (includes acquisition, operation and HIV test costs, $29.30 per negative result and $31.30 per positive result). We conducted extensive sensitivity analyses to evaluate input uncertainty. Model outcomes included site of HIV diagnosis, life expectancy, medical costs, and the incremental cost-effectiveness ratio (ICER) of the intervention compared to medical facility-based testing. We considered the intervention to be "very cost-effective" when the ICER was less than South Africa's annual per capita Gross Domestic Product (GDP) ($8,200 in 2012). We projected that, with medical facility-based testing, the discounted (undiscounted) HIV-infected population life expectancy was 132.2 (197.7) months; this increased to 140.7 (211.7) months with the addition of the mobile unit. The ICER for the mobile unit was $2,400/year of life saved (YLS). Results were most sensitive to the previously undiagnosed HIV prevalence, linkage to care rates, and frequency of HIV testing at medical facilities. The addition of mobile HIV screening to current testing programs can improve survival and be very cost-effective in South Africa and other resource-limited settings, and should be a priority.
Coyle, Catelyn; Kwakwa, Helena
2016-01-01
Despite common risk factors, screening for hepatitis C virus (HCV) and HIV at the same time as part of routine medical care (dual-routine HCV/HIV testing) is not commonly implemented in the United States. This study examined improvements in feasibility of implementation, screening increase, and linkage to care when a dual-routine HCV/HIV testing model was integrated into routine primary care. National Nursing Centers Consortium implemented a dual-routine HCV/HIV testing model at four community health centers in Philadelphia, Pennsylvania, on September 1, 2013. Routine HCV and opt-out HIV testing replaced the routine HCV and opt-in HIV testing model through medical assistant-led, laboratory-based testing and electronic medical record modification to prompt, track, report, and facilitate reimbursement for tests performed on uninsured individuals. This study examined testing, seropositivity, and linkage-to-care comparison data for the nine months before (December 1, 2012-August 31, 2013) and after (September 1, 2013-May 31, 2014) implementation of the dual-routine HCV/HIV testing model. A total of 1,526 HCV and 1,731 HIV tests were performed before, and 1,888 HCV and 3,890 HIV tests were performed after dual-routine testing implementation, resulting in a 23.7% increase in HCV tests and a 124.7% increase in HIV tests. A total of 70 currently HCV-infected and four new HIV-seropositive patients vs. 101 HCV-infected and 13 new HIV-seropositive patients were identified during these two periods, representing increases of 44.3% for HCV antibody-positive and RNA-positive tests and 225.0% for HIV-positive tests. Linkage to care increased from 27 currently infected HCV--positive and one HIV-positive patient pre-dual-routine testing to 39 HCV--positive and nine HIV-positive patients post-dual-routine testing. The dual-routine HCV/HIV testing model shows that integrating dual-routine testing in a primary care setting is possible and leads to increased HCV and HIV screening, enhanced seropositivity diagnosis, and improved linkage to care.
Kwakwa, Helena
2016-01-01
Objective Despite common risk factors, screening for hepatitis C virus (HCV) and HIV at the same time as part of routine medical care (dual-routine HCV/HIV testing) is not commonly implemented in the United States. This study examined improvements in feasibility of implementation, screening increase, and linkage to care when a dual-routine HCV/HIV testing model was integrated into routine primary care. Methods National Nursing Centers Consortium implemented a dual-routine HCV/HIV testing model at four community health centers in Philadelphia, Pennsylvania, on September 1, 2013. Routine HCV and opt-out HIV testing replaced the routine HCV and opt-in HIV testing model through medical assistant-led, laboratory-based testing and electronic medical record modification to prompt, track, report, and facilitate reimbursement for tests performed on uninsured individuals. This study examined testing, seropositivity, and linkage-to-care comparison data for the nine months before (December 1, 2012–August 31, 2013) and after (September 1, 2013–May 31, 2014) implementation of the dual-routine HCV/HIV testing model. Results A total of 1,526 HCV and 1,731 HIV tests were performed before, and 1,888 HCV and 3,890 HIV tests were performed after dual-routine testing implementation, resulting in a 23.7% increase in HCV tests and a 124.7% increase in HIV tests. A total of 70 currently HCV-infected and four new HIV-seropositive patients vs. 101 HCV-infected and 13 new HIV-seropositive patients were identified during these two periods, representing increases of 44.3% for HCV antibody-positive and RNA-positive tests and 225.0% for HIV-positive tests. Linkage to care increased from 27 currently infected HCV--positive and one HIV-positive patient pre-dual-routine testing to 39 HCV--positive and nine HIV-positive patients post-dual-routine testing. Conclusion The dual-routine HCV/HIV testing model shows that integrating dual-routine testing in a primary care setting is possible and leads to increased HCV and HIV screening, enhanced seropositivity diagnosis, and improved linkage to care. PMID:26862229
Tomazoni, Andréia; Rocha, Patrícia Kuerten; de Souza, Sabrina; Anders, Jane Cristina; de Malfussi, Hamilton Filipe Correia
2014-01-01
OBJECTIVE: to verify the assessment of the patient safety culture according to the function and length of experience of the nursing and medical teams at Neonatal Intensive Care Units. METHOD: quantitative survey undertaken at four Neonatal Intensive Care Units in Florianópolis, Brazil. The sample totaled 141 subjects. The data were collected between February and April 2013 through the application of the Hospital Survey on Patient Safety Culture. For analysis, the Kruskal-Wallis and Chi-Square tests and Cronbach's Alpha coefficient were used. Approval for the research project was obtained from the Ethics Committee, CAAE: 05274612.7.0000.0121. RESULTS: differences in the number of positive answers to the Hospital Survey on Patient Safety Culture, the safety grade and the number of reported events were found according to the professional characteristics. A significant association was found between a shorter Length of work at the hospital and Length of work at the unit and a larger number of positive answers; longer length of experience in the profession represented higher grades and less reported events. The physicians and nursing technicians assessed the patient safety culture more positively. Cronbach's alpha demonstrated the reliability of the instrument. CONCLUSION: the differences found reveal a possible relation between the assessment of the safety culture and the subjects' professional characteristics at the Neonatal Intensive Care Units. PMID:25493670
Brown, Daniel M; Barbara, Abrams; Cohen, Alison K; Rehkopf, David H
2017-12-01
While there is an association of greater short-term weight gain with childbearing among women, less is known about longer-term weight gain, whether men have similar gains, and how this varies by race/ethnicity and socioeconomic position. Our cohort consisted of a nationally representative sample of 7,356 Americans with oversampling of Black and Hispanic populations. We estimated the associations between number of biological children and parental weight, measured as both change in self-reported body mass index (BMI) from age 18 and overweight/obese status (BMI ≥ 25) at age 40. We performed multivariate linear and logistic regression analysis and tested for effect modification by gender. For change in BMI, men gained on average 0.28 BMI (95% CI: (0.01, 0.55)) units per child, while women gained 0.13 units per child (95% CI: (-0.22, 0.48)). The adjusted odds ratios for overweight/obesity associated with each child were 1.32 (95% CI: (1.11, 1.58)) for men and 1.15 (95% CI: (1.01, 1.31)) for women. Stratified analyses by race/ethnicity and socioeconomic position suggested that the observed full-cohort differences were driven primarily by gendered differences in low-income Hispanics and Whites - with the greatest associations among Hispanic men. For example, among low-income Hispanic men we observed a positive relationship between the number of children and weight change by age 40, with average weight change of 0.47 units per child (95%CI: (-0.65, 1.59 For low-income Hispanic women, however, the average weight change was -0.59 units per child (95%CI: (-1.70, 0.47), and the P-value for the test of interaction between gender and number of children was P < 0.001. Our findings suggest that the shared social and economic aspects of raising children play an important role in determining parental weight at mid-life.
Plasma Deflection Test Setup for E-Sail Propulsion Concept
NASA Technical Reports Server (NTRS)
Andersen, Allen; Vaughn, Jason; Schneider, Todd; Wright, Ken
2016-01-01
The Electronic Sail or E-Sail is a novel propulsion concept based on momentum exchange between fast solar wind protons and the plasma sheath of long positively charged conductors comprising the E-Sail. The effective sail area increases with decreasing plasma density allowing an E-Sail craft to continue to accelerate at predicted ranges well beyond the capabilities of existing electronic or chemical propulsion spacecraft. While negatively charged conductors in plasmas have been extensively studied and flown, the interaction between plasma and a positively charged conductor is not well studied. We present a plasma deflection test method using a differential ion flux probe (DIFP). The DIFP measures the angle and energy of incident ions. The plasma sheath around a charged body can measured by comparing the angular distribution of ions with and without a positively charged test body. These test results will be used to evaluate numerical calculations of expected thrust per unit length of conductor in the solar wind plasma. This work was supported by a NASA Space Technology Research Fellowship.
Management System for Integrating Basic Skills 2 Training and Unit Training Programs
1983-09-01
Social Sciences. NOTEs The findings in this report are not to be construed as en official Department of the Army position, unless so designated by other...This report describes methods used and results obtained in the design , development, and field test of a management system and curriculum components...for integrating the Army’s Basic Skills Education Program, Phase II (BSEP II) and unit training programs. The curriculum components are designed to
2014-03-27
2009). Choosing the Right Type of Rotation in PCA and EFA. JALT Testing & Evaluation Newsletter , 13 (3), 20-25. 102 Bryman , A . (2006). Integrating...FORCE INSTITUTE OF TECHNOLOGY Wright-Patterson Air Force Base, Ohio DISTRIBUTION STATEMENT A . APPROVED FOR PUBLIC RELEASE...official policy or position of the United States Air Force, Department of Defense, or the United States government. This material is declared a work of
Multiple factors contribute to positive results for hepatitis A virus immunoglobulin M antibody.
Alatoom, Adnan; Ansari, M Qasim; Cuthbert, Jennifer
2013-01-01
In the United States, a successful vaccination program for hepatitis A virus (HAV) infection has decreased both its incidence and the true positive rate for diagnostic immunoglobulin M (IgM) antibody to HAV in acute hepatitis. To survey positive results of HAV IgM tests and determine the effect of changing ordering options. We reviewed all positive results for IgM antibody to HAV between January 2007 and December 2010. Patient demographics, clinical history, and laboratory data were recorded and the encounter, order, and reason for test reviewed. Each result was categorized as indicating acute, recent, resolved, or indeterminate HAV infection. A total of 10,735 tests were performed; 35 patients had 49 positive results. Most positive test results were associated with outpatient visits and were ordered in the assessment of patients with liver disease, but not clinical acute hepatitis. In the final analysis, 4 patients had acute hepatitis A and 20 individual patients had recent and/or resolved hepatitis. All but 1 of the remaining 11 patients had another established cause of liver disease with a positive IgM HAV antibody test result; data to determine causality were insufficient. The total number of tests requested annually decreased more than 35% with the introduction of computerized physician order entry. Current assays for IgM HAV antibodies are overused in the absence of clinical acute hepatitis; future clinical decision support may improve patterns of order entry. Most patients have findings consistent with HAV exposure but not acute hepatitis; dormant viral infection may be a continuing source of antigen.
Macy, Eric; Ngor, Eunis W
2013-01-01
Penicillin skin testing is rarely used to undiagnose penicillin "allergy" in the United States, partially because of concern that commercially available materials are inadequate. We determined whether skin testing with only commercially available penicilloyl-poly-lysine and penicillin followed by an oral amoxicillin challenge, if skin test-negative, can safely identify clinically significant penicillin allergy. Five hundred sequential persons with positive history of penicillin "allergy" were evaluated by skin testing with penicilloyl-poly-lysine and penicillin between June 8, 2010, and March 29, 2012. All persons with negative skin tests were given an oral amoxicillin challenge and observed for 1 hour. Persons undergoing penicillin allergy testing were representative of all health plan members with penicillin allergy. Only 4 persons (0.8%; 95% CI, 0.32%-2.03%) had a positive skin test result. Only 4 persons (0.8%; 95% CI, 0.32%-2.03%) had an acute objective oral amoxicillin challenge reaction. Fifteen persons (3.0%; 95% CI, 1.83%-4.98%) had subjective oral challenge reactions, either acute transient itching or dizziness. All were women and 11 (73.3%) had multiple drug intolerance syndrome. None had severe reactions or objective signs. These were not considered to be positive challenge reactions. Sixty-eight subjects (13.6%) who were negative on testing were exposed to 88 courses of penicillins during 90 days of follow-up. New reactions were reported after 4 courses (4.5%), 3 (75%) occurring in subjects with multiple drug intolerance syndrome. Penicillin skin testing, using only penicilloyl-poly-lysine and penicillin, followed by oral amoxicillin challenge, if negative, can safely identify clinically significant IgE-mediated penicillin allergy in patients who use health care in the United States at this time. Copyright © 2013 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Encephalitozoon cuniculi antibodies in a specific-pathogen-free rabbit unit.
Bywater, J E; Kellett, B S
1978-01-01
We describe our discovery of Encephalitozoon cuniculi antibodies in a specific-pathogen-free rabbit colony. Small-sized samples had failed to reveal the presence of infection with a prevalence of about 5%. Using an India ink immunoreaction test by which we were able to visualize both negative and positive reactions, we were able to undertake a 100% screen of the colony of more than 700 rabbits and to repeat this 4 weeks later when we had culled the positive reactors. By collating the results of those tests with the results of tests on previously collected samples, we have been able to discuss and observe age and sex susceptibilities and the mode of transmission of the naturally occurring disease. PMID:151081
From it's position at 175 statute miles above Earth, the Space Shuttle Endeavour has encountered
NASA Technical Reports Server (NTRS)
1996-01-01
STS-77 ESC VIEW --- From it's position at 175 statute miles above Earth, the Space Shuttle Endeavour has encountered some colorful and attractive scenes heading into sunsets and sunrises. This particular encounter, captured with an Electronic Still Camera (ESC), occurred on flight day four, during which the six-member crew deployed the Passive Aerodynamically Stabilized Magnetically Damped Satellite (PAMS) - Satellite Test Unit (STU). GMT: 13:48:47.
Cellular and humoral immunity after vaccination or natural mumps infection.
Terada, Kihei; Hagihara, Kimiko; Oishi, Tomohiro; Miyata, Ippei; Akaike, Hiroto; Ogita, Satoko; Ohno, Naoki; Ouchi, Kazunobu
2017-08-01
This study measured cell-mediated immunity (CMI) and serum antibody to clarify the basis of breakthrough after vaccination and reinfection after mumps. From a pool of 54 college students, 17 seronegative subjects and 14 subjects with intermediate level of antibodies against mumps were vaccinated with a monovalent mumps vaccine, and CMI was assessed using interferon-γ release assay. CMI positivity according to pre-existing antibody level, defined as titer <2.0 index units, negative; 2.0-3.9 index units, intermediate; and ≥4.0 index units, positive, was 8/17 (47.1%), 9/14 (64.3%) and 19/23 (82.6%) before vaccination, respectively. Of the 17 seronegative subjects, seven (41.2%) had a history of vaccination and/or natural infection, four (57.1%) of whom were CMI positive or intermediate. Ten (71%) of 14 subjects with intermediate antibody level had a history of vaccination or natural infection, eight (80%) of whom were CMI positive or intermediate. After vaccination the interferon (IFN)-γ and antibody titers increased significantly, but seven (41.2%) of the 17 seronegative subjects and 13 (92.9%) of the 14 intermediate-level subjects tested positive for both antibody and CMI. In a comparison of the natural infection group (confirmed as IgG seropositive and/or CMI positive without vaccination) versus the vaccination group, IgG antibody titer (mean ± SD) was 14.4 ± 8.0 versus 3.6 ± 2.4 index units (P < 0.01) and IFN-γ was 122.7 ± 90.0 pg/mL versus 59.5 ± 37.8 pg/mL (P > 0.05), respectively. Vaccination or even natural mumps infection did not always induce both cellular and humoral immunity. © 2017 Japan Pediatric Society.
Seth, Puja; Figueroa, Argelia; Wang, Guoshen; Reid, Laurie; Belcher, Lisa
2016-01-01
Background Because of health disparities, incarcerated persons are at higher risk for multiple health issues, including HIV. Correctional facilities have an opportunity to provide HIV services to an underserved population. This article describes Centers for Disease Control and Prevention (CDC)–funded HIV testing and service delivery in correctional facilities. Methods Data on HIV testing and service delivery were submitted to CDC by 61 health department jurisdictions in 2013. HIV testing, HIV positivity, receipt of test results, linkage, and referral services were described, and differences across demographic characteristics for linkage and referral services were assessed. Finally, trends were examined for HIV testing, HIV positivity, and linkage from 2009 to 2013. Results Of CDC-funded tests in 2013 among persons 18 years and older, 254,719 (7.9%) were conducted in correctional facilities. HIV positivity was 0.9%, and HIV positivity for newly diagnosed persons was 0.3%. Blacks accounted for the highest percentage of HIV-infected persons (1.3%) and newly diagnosed persons (0.5%). Only 37.9% of newly diagnosed persons were linked within 90 days; 67.5% were linked within any time frame; 49.7% were referred to partner services; and 45.2% were referred to HIV prevention services. There was a significant percent increase in HIV testing, overall HIV positivity, and linkage from 2009 to 2013. However, trends were stable for newly diagnosed persons. Conclusions Identification of newly diagnosed persons in correctional facilities has remained stable from 2009 to 2013. Correctional facilities seem to be reaching blacks, likely due to higher incarceration rates. The current findings indicate that improvements are needed in HIV testing strategies, service delivery during incarceration, and linkage to care postrelease. PMID:26462190
A Foot-Mounted Inertial Measurement Unit (IMU) Positioning Algorithm Based on Magnetic Constraint
Zou, Jiaheng
2018-01-01
With the development of related applications, indoor positioning techniques have been more and more widely developed. Based on Wi-Fi, Bluetooth low energy (BLE) and geomagnetism, indoor positioning techniques often rely on the physical location of fingerprint information. The focus and difficulty of establishing the fingerprint database are in obtaining a relatively accurate physical location with as little given information as possible. This paper presents a foot-mounted inertial measurement unit (IMU) positioning algorithm under the loop closure constraint based on magnetic information. It can provide relatively reliable position information without maps and geomagnetic information and provides a relatively accurate coordinate for the collection of a fingerprint database. In the experiment, the features extracted by the multi-level Fourier transform method proposed in this paper are validated and the validity of loop closure matching is tested with a RANSAC-based method. Moreover, the loop closure detection results show that the cumulative error of the trajectory processed by the graph optimization algorithm is significantly suppressed, presenting a good accuracy. The average error of the trajectory under loop closure constraint is controlled below 2.15 m. PMID:29494542
A Foot-Mounted Inertial Measurement Unit (IMU) Positioning Algorithm Based on Magnetic Constraint.
Wang, Yan; Li, Xin; Zou, Jiaheng
2018-03-01
With the development of related applications, indoor positioning techniques have been more and more widely developed. Based on Wi-Fi, Bluetooth low energy (BLE) and geomagnetism, indoor positioning techniques often rely on the physical location of fingerprint information. The focus and difficulty of establishing the fingerprint database are in obtaining a relatively accurate physical location with as little given information as possible. This paper presents a foot-mounted inertial measurement unit (IMU) positioning algorithm under the loop closure constraint based on magnetic information. It can provide relatively reliable position information without maps and geomagnetic information and provides a relatively accurate coordinate for the collection of a fingerprint database. In the experiment, the features extracted by the multi-level Fourier transform method proposed in this paper are validated and the validity of loop closure matching is tested with a RANSAC-based method. Moreover, the loop closure detection results show that the cumulative error of the trajectory processed by the graph optimization algorithm is significantly suppressed, presenting a good accuracy. The average error of the trajectory under loop closure constraint is controlled below 2.15 m.
Foldi, Nancy S
2011-01-01
Story recall in Alzheimer disease (AD) is typically used as a measure of episodic memory, but the degree to which recall is dependent on available attentional resources is not fully understood. The current study investigated how measures of attention were associated to verbatim recall (exact reproduction) or gist recall (relevant semantic meaning). Sixteen participants with AD and 16 age-matched healthy older adults recalled a story on immediate free recall and recognition. Controls recalled more units overall than AD. A group X response interaction revealed more gist than verbatim recall in AD, but those with mild disease generated approximately the same number gist responses as controls. For each group, qualitatively different attentional resources were associated with recall units. In controls, verbatim units correlated positively with primacy serial position items of the California Verbal Learning Test II (CVLTII), suggesting that episodic buffer resources may be associated with story recall. In AD, gist units were positively correlated with digits forward, but inversely related to the CVLTII primacy region items, suggesting reliance on low-level capacity resources. Possible explanations of the impaired performance in AD may be a bias in favor of gist processing, poor verbatim encoding, and/or processing failure at the level of the episodic buffer.
Patanwala, Insiyyah Y.; Bauer, Heidi M.; Miyamoto, Justin; Park, Ina U.; Huchko, Megan J.; Smith-McCune, Karen K.
2013-01-01
Our objective was to assess the sensitivity and specificity of human papillomavirus (HPV) testing for cervical cancer screening in randomized trials. We conducted a systematic literature search of the following databases: MEDLINE, CINAHL, EMBASE, and Cochrane. Eligible studies were randomized trials comparing HPV-based to cytology-based screening strategies, with disease status determined by colposcopy/biopsy for participants with positive results. Disease rates (cervical intraepithelial neoplasia [CIN]2 or greater and CIN3 or greater), sensitivity, and positive predictive value were abstracted or calculated from the articles. Six studies met inclusion criteria. Relative sensitivities for detecting CIN3 or greater of HPV testing-based strategies vs cytology ranged from 0.8 to 2.1. The main limitation of our study was that testing methodologies and screening/management protocols were highly variable across studies. Screening strategies in which a single initial HPV-positive test led to colposcopy were more sensitive than cytology but resulted in higher colposcopy rates. These results have implications for cotesting with HPV and cytology as recommended in the United States. PMID:23159693
1987-12-15
interactions (ac- either positive or negative surface cording to Bakker), occurred for all charge and ]inked this to OB bchavior. tested btomaterinls, but were...an~d 10 weeks. treated for edentulousuesa an excellent At t*e end of the test period, the imp- function can be a-intained for decades. plants vers...covotiers and tested in tjtmro as probably collagen) rather than synovium potential intestinal bloadhesives. The is the sperific target for microbial ad
Will the leading firm continue to dominate the market in the Taiwan notebook industry?
NASA Astrophysics Data System (ADS)
Chu, Hsiao-Ping; Yeh, Ming-Liang; Sher, Peter J.; Chiu, Yi-Chia
2007-09-01
This study investigates whether the market share leader in the notebook industry in Taiwan is likely to maintain its dominant position. Market share data are used to investigate the intensity of competitiveness in the industry, and data on the gap in market shares are employed to elucidate the dominance of the leading firm in Taiwan's notebook industry during the 1998-2004 period. The newly developed Panel SURADF tests advanced by Breuer et al. [Misleading inferences from panel unit root tests with an illustration from purchasing power parity, Rev. Int. Econ. 9 (3) (2001) 482-493] are employed to determine whether the market share gap is stationary or not. Unlike other panel-based unit root tests which are joint tests of a unit root for all members of a panel and are incapable of determining the mix of I(0) and I(1) series in a panel setting, the Panel SURADF tests have the advantage of being able to investigate a separate unit root null hypothesis for each individual panel member and are, therefore, able to identify how many and which series in a panel are stationary processes. The empirical results from several panel-based unit root tests substantiate that the market shares of the firms studied here are non-stationary, indicating that Taiwan's notebook industry is highly competitive; however, Breuer et al.'s [12] Panel SURADF tests unequivocally show that only Compal is stationary with respect to market share gap. In terms of sales volume, Compal is the second largest firm in the notebook industry in Taiwan, and the results indicate that it alone has the opportunity to become the market share leader in the notebook industry.
Büchner, Ané; Du Plessis, Nicolette M; Reynders, David T; Omar, Fareed E; Mayaphi, Simnikiwe H; Haeri Mazanderani, Ahmad F; Avenant, Theunis
2015-11-01
Hospital-acquired hepatitis B virus (HBV) infection has been well described and continues to occur worldwide. Recent nosocomial outbreaks have been linked to unsafe injection practices, use of multi-dose vials, and poor staff compliance with standard precautions. This report describes a nosocomial outbreak that occurred in a pediatric hematology and oncology unit of a large academic hospital, the epidemiological investigation of the outbreak, and preventive measures implemented to limit further in-hospital transmission. Outbreak investigation including contact tracing and HBV screening were initially carried out on all patients seen by the unit during the same period as the first three cases. Routine screening for the entire patient population of the unit was initiated in February 2013 when it was realized that numerous patients may have been exposed. Forty-nine cases of HBV infection were confirmed in 408 patients tested between July 2011 and October 2013. Phylogenetic analysis of the HBV preC/C gene nucleotide sequences revealed that all tested outbreak strains clustered together. Most (67%) patients were HBeAg positive. The cause of transmission could not be established. Preventive measures targeted three proposed routes. HBV screening and vaccination protocols were started in the unit. The high number of HBeAg positive patients, together with suspected lapses in infection prevention and control measures, are believed to have played a major role in the transmission. Measures implemented to prevent further in-hospital transmission were successful. On-going HBV screening and vaccination programs in pediatric hematology and oncology units should become standard of care. © 2015 Wiley Periodicals, Inc.
PERFORMANCE EVALUATION OF A PROTOTYPE ARCHITECT ANTIBODY ASSAY FOR BABESIA MICROTI.
Cheng, Kevin; Coller, Kelly E; Marohnic, Christopher C; Pfeiffer, Zachary A; Fino, James R; Elsing, Randee R; Bergsma, Janet; Marcinkus, Marilee A; Kar, Alak K; Gumbs, Orlando H; Otis, Kathy S; Fishpaugh, Jeffrey; Schultz, Phillip W; Pope, Mark R; Narvaez, Alfredo R; Wong, Susan J; Madison-Antenucci, Susan; Leary, Thomas P; Dawson, George J
2018-05-09
The tick-borne protozoan Babesia microti is responsible for more than 200 cases of transfusion-transmitted babesiosis (TTB) infection in the United States over the last 30 years. Measures to mitigate the risk of TTB include nucleic acid testing (NAT) and B. microti antibody testing. A fully automated prototype B. microti antibody test was developed on the ARCHITECT instrument. The specificity was determined to be 99.98% in volunteer blood donors (n=28,740) from areas considered as low endemic for B. microti The sensitivity of the prototype test was studied in experimentally-infected macaques; a total of 128 samples were detected compared to 125 with the indirect fluorescent antibody test (IFA), additionally, 83 (89.2%) of the PCR positive samples were detected compared to 81 (87.1%) using the IFA test. All PCR positive samples that tested negative in the prototype antibody test were pre-seroconversion period samples. Following seroconversion, periods of intermittent parasitemia occurred; 17 PCR negative samples drawn in-between PCR positive bleed dates, tested positive both by the prototype test (robust reactivity) and IFA (marginal reactivity) prior to the administration of therapeutic drugs, indicating that the PCR test failed to detect samples from persistently infected macaques. The prototype assay detected 56 of 58 (96.6%) human subjects diagnosed with clinical babesiosis by both PCR and IFA testing. Overall, the prototype anti-babesia assay provides a highly sensitive and specific test for the diagnosis of B. microti infection. While PCR is preferred for detection of window period parasitemia, antibody tests detect infected subjects during periods of low level parasitemia. Copyright © 2018 Cheng et al.
Experiments in fault tolerant software reliability
NASA Technical Reports Server (NTRS)
Mcallister, David F.; Vouk, Mladen A.
1989-01-01
Twenty functionally equivalent programs were built and tested in a multiversion software experiment. Following unit testing, all programs were subjected to an extensive system test. In the process sixty-one distinct faults were identified among the versions. Less than 12 percent of the faults exhibited varying degrees of positive correlation. The common-cause (or similar) faults spanned as many as 14 components. However, a majority of these faults were trivial, and easily detected by proper unit and/or system testing. Only two of the seven similar faults were difficult faults, and both were caused by specification ambiguities. One of these faults exhibited variable identical-and-wrong response span, i.e. response span which varied with the testing conditions and input data. Techniques that could have been used to avoid the faults are discussed. For example, it was determined that back-to-back testing of 2-tuples could have been used to eliminate about 90 percent of the faults. In addition, four of the seven similar faults could have been detected by using back-to-back testing of 5-tuples. It is believed that most, if not all, similar faults could have been avoided had the specifications been written using more formal notation, the unit testing phase was subject to more stringent standards and controls, and better tools for measuring the quality and adequacy of the test data (e.g. coverage) were used.
Risk management, or just a different risk?
Freer, Y; Lyon, A
2006-09-01
National reporting of adverse incidents has resulted in a number of clinical alerts being issued. Despite a lack of evidence, these alerts are often accompanied by a mandatory requirement to alter practice. There is likely to be clinician resistance to such a method of change management, particularly where evidence of safety is missing. To determine the level of implementation within neonatal units of an alert requiring the change from litmus to pH paper to test nasogastric tube position. A questionnaire sent to all neonatal units in the United Kingdom with more than 12 cots. From the 207 questionnaires sent, there were 165 (80%) responses. Fifty five percent of units were still using litmus. All continued to use supplementary tests not recommended in best practice statements issued at the time of the alert. There was considerable variation in the pH value at which it was considered safe to feed. Nine months after the alert, more than half the units had not changed to pH paper, and supplementary methods of testing were still being used. The wide range of pH values highlights the uncertainty about the "normal" gastric pH in the newborn. The evidence that, in neonatal units, changing to pH paper is safer than the long established use of litmus is lacking. Recommendations for change in practice must be based on good information and not seen just as a "knee jerk" response to adverse incidents.
Michelin, Birgit D. A.; Hadžisejdić, Ita; Bozic, Michael; Grahovac, Maja; Hess, Markus; Grahovac, Blaženka; Marth, Egon; Kessler, Harald H.
2008-01-01
Whole blood has been found to be a reliable matrix for the detection and quantitation of cytomegalovirus (CMV) DNA. In this study, the performance of the artus CMV LightCycler (LC) PCR kit in conjunction with automated sample preparation on a BioRobot EZ1 workstation was evaluated. The accuracy, linearity, analytical sensitivity, and inter- and intra-assay variations were determined. A total of 102 clinical EDTA whole-blood samples were investigated, and results were compared with those obtained with the in vitro diagnostics (IVD)/Conformité Européene (CE)-labeled CMV HHV6,7,8 R-gene quantification kit. When the accuracy of the new kit was tested, seven of eight results were found to be within ±0.5 log10 unit of the expected panel results. Determination of linearity resulted in a quasilinear curve over more than 5 log units. The lower limit of detection of the assay was determined to be 139 copies/ml in EDTA whole blood. The interassay variation ranged from 15 to 58%, and the intra-assay variation ranged from 7 to 35%. When clinical samples were tested and the results were compared with those of the routinely used IVD/CE-labeled assay, 53 samples tested positive and 13 samples tested negative by both of the assays. One sample was found to be positive with the artus CMV LC PCR kit only, and 35 samples tested positive with the routinely used assay only. The majority of discrepant results were found with low-titer samples. In conclusion, use of the artus CMV LC PCR kit in conjunction with automated sample preparation on the BioRobot EZ1 workstation may be suitable for the detection and quantitation of CMV DNA in EDTA whole blood in the routine low-throughput laboratory; however, low-positive results may be missed by this assay. PMID:18272703
Michelin, Birgit D A; Hadzisejdic, Ita; Bozic, Michael; Grahovac, Maja; Hess, Markus; Grahovac, Blazenka; Marth, Egon; Kessler, Harald H
2008-04-01
Whole blood has been found to be a reliable matrix for the detection and quantitation of cytomegalovirus (CMV) DNA. In this study, the performance of the artus CMV LightCycler (LC) PCR kit in conjunction with automated sample preparation on a BioRobot EZ1 workstation was evaluated. The accuracy, linearity, analytical sensitivity, and inter- and intra-assay variations were determined. A total of 102 clinical EDTA whole-blood samples were investigated, and results were compared with those obtained with the in vitro diagnostics (IVD)/Conformité Européene (CE)-labeled CMV HHV6,7,8 R-gene quantification kit. When the accuracy of the new kit was tested, seven of eight results were found to be within +/-0.5 log(10) unit of the expected panel results. Determination of linearity resulted in a quasilinear curve over more than 5 log units. The lower limit of detection of the assay was determined to be 139 copies/ml in EDTA whole blood. The interassay variation ranged from 15 to 58%, and the intra-assay variation ranged from 7 to 35%. When clinical samples were tested and the results were compared with those of the routinely used IVD/CE-labeled assay, 53 samples tested positive and 13 samples tested negative by both of the assays. One sample was found to be positive with the artus CMV LC PCR kit only, and 35 samples tested positive with the routinely used assay only. The majority of discrepant results were found with low-titer samples. In conclusion, use of the artus CMV LC PCR kit in conjunction with automated sample preparation on the BioRobot EZ1 workstation may be suitable for the detection and quantitation of CMV DNA in EDTA whole blood in the routine low-throughput laboratory; however, low-positive results may be missed by this assay.
Childs, Tristan; Simms, Ian; Alexander, Sarah; Eastick, Kirstine; Hughes, Gwenda; Field, Nigel
2015-01-01
United Kingdom (UK) national data show a sharp increase in diagnoses of lymphogranuloma venereum (LGV) since 2012. Most cases are in men who have sex with men (MSM) living in London, with high rates of co-infection with HIV and other sexually transmitted infections. In light of these data, and the recent finding that one quarter of LGV infections may be asymptomatic, clinicians should be vigilant in testing for LGV, including in asymptomatic HIV-positive MSM.
2002-05-01
About half of the nearly 1 million HIV-positive people in the United States are not receiving ongoing care, and this largely is because they have not yet been diagnosed, according to data from the Centers for Disease Control and Prevention. CDC officials estimate that HIV prevalence in the United States has increased by about 50,000 people since 1998 and that there are now between 850,000 and 950,000 people infected with the virus.
Validity of suspected alcohol and drug violations in aviation employees.
Li, Guohua; Brady, Joanne E; DiMaggio, Charles; Baker, Susan P; Rebok, George W
2010-10-01
In the United States, transportation employees who are suspected of using alcohol and drugs are subject to reasonable-cause testing. This study aims to assess the validity of suspected alcohol and drug violations in aviation employees. Using reasonable-cause testing and random testing data from the Federal Aviation Administration for the years 1995-2005, we calculated the positive predictive value (PPV) and positive likelihood ratio (LR+) of suspected alcohol and drug violations. The true status of violations was based on testing results, with an alcohol violation being defined as a blood alcohol concentration of ≥0.04 mg/dl and a drug violation as a test positive for marijuana, cocaine, amphetamines, phencyclidine or opiates. During the 11-year study period, a total of 2284 alcohol tests and 2015 drug tests were performed under the reasonable-cause testing program. The PPV was 37.7% [95% confidence interval (CI), 35.7-39.7%] for suspected alcohol violations and 12.6% (95% CI, 11.2-14.1%) for suspected drug violations. Random testing revealed an overall prevalence of 0.09% for alcohol violations and 0.6% for drug violations. The LR+ was 653.6 (95% CI, 581.7-734.3) for suspected alcohol violations and 22.5 (95% CI, 19.6-25.7) for suspected drug violations. The discriminative power of reasonable-cause testing suggests that, despite its limited positive predictive value, physical and behavioral observation represents an efficient screening method for detecting alcohol and drug violations. The limited positive predictive value of reasonable-cause testing in aviation employees is due in part to the very low prevalence of alcohol and drug violations. © 2010 The Authors, Addiction © 2010 Society for the Study of Addiction.
Validity of Suspected Alcohol and Drug Violations in Aviation Employees
Li, Guohua; Brady, Joanne E.; DiMaggio, Charles; Baker, Susan P.; Rebok, George W.
2012-01-01
Introduction In the United States, transportation employees who are suspected of using alcohol and drugs are subject to reasonable-cause testing. This study aims to assess the validity of suspected alcohol and drug violations in aviation employees. Methods Using reasonable-cause testing and random testing data from the Federal Aviation Administration for the years 1995 through 2005, we calculated the positive predictive value (PPV) and positive likelihood ratio (LR+) of suspected alcohol and drug violations. The true status of violations was based on testing results, with an alcohol violation being defined as a blood alcohol concentration of ≥40 mg/dL and a drug violation as a test positive for marijuana, cocaine, amphetamines, phencyclidine, or opiates. Results During the 11-year study period, a total of 2,284 alcohol tests and 2,015 drug tests were performed under the reasonable-cause testing program. The PPV was 37.7% [95% confidence interval (CI), 35.7–39.7%] for suspected alcohol violations and 12.6% (95% CI, 11.2–14.1%) for suspected drug violations. Random testing revealed an overall prevalence of 0.09% (601/649,796) for alcohol violations and 0.6% (7,211/1,130,922) for drug violations. The LR+ was 653.6 (95% CI, 581.7–734.3) for suspected alcohol violations and 22.5 (95% CI, 19.6–25.7) for suspected drug violations. Discussion The discriminative power of reasonable-cause testing suggests that, despite its limited positive predictive value, physical and behavioral observation represents an efficient screening method for detecting alcohol and drug violations. The limited positive predictive value of reasonable-cause testing in aviation employees is due in part to the very low prevalence of alcohol and drug violations. PMID:20712820
Pre-Participation Musculoskeletal and Cardiac Screening of Male Athletes in the United Arab Emirates
Alattar, A; Ghani, S; Mahdy, N; Hussain, H; Maffulli, N
2014-01-01
This study presents the results of pre-participation musculoskeletal and cardiac screening using the Lausanne recommendations, which include a personal and family history, physical examination and electrocardiography. Cross sectional study using the Lausanne screenings and the European Society of Cardiology (ESC) recommendations carried out at Al-Ahli club in Dubai, United Arab Emirates. 230 male athletes participating in organised sports were included. Exclusion criteria were those under 14 or over 35 years old, females and athletes with established cardiovascular disease. Primary outcome are the results of Lausanne screening with outline of the negative, positive and false positive results and number needed to screen. Secondary outcomes include the results of musculoskeletal and neurological screening. A total of 174 (76%) athletes had a negative screening result. Fifty-four athletes (23%) underwent additional testing. Forty-seven athletes (20.4%) had false positive screening results. Seven athletes (3%) had a positive screening result and four athletes (2%) were restricted from sport. The number of athletes needed to screen to detect one lethal cardiovascular condition was 33 athletes. The Lausanne recommendations are well suited for the United Arab Emirates. The number needed to screen to detect one athlete with serious cardiovascular disease is acceptable at 33. PMID:24809035
Nelson, Jeffrey T.; Orloski, Kathleen A.; Lloyd, Audra L.; Camacho, Mark; Schoenbaum, Mark A.; Robbe-Austerman, Suelee; Thomsen, Bruce V.; Hall, S. Mark
2012-01-01
In 2011, the United States Department of Agriculture conducted a project in which elk (Cervus elaphus spp.), white-tailed deer (WTD) (Odocoileus virginianus), and reindeer (Rangifer tarandus) were evaluated by the single cervical tuberculin test (SCT), comparative cervical tuberculin test (CCT), and serologic tests. The rapid antibody detection tests evaluated were the CervidTB Stat-Pak (Stat-Pak), and the Dual Path Platform VetTB (DPP). Blood was collected from presumably uninfected animals prior to tuberculin injection for the SCT. A total of 1,783 animals were enrolled in the project. Of these, 1,752 (98.3%) were classified as presumably uninfected, based on originating from a captive cervid herd with no history of exposure to TB. Stat-Pak specificity estimates were 92.4% in reindeer, 96.7% in WTD, and 98.3% in elk and were not significantly different from SCT specificity estimates. Using the DPP in series on Stat-Pak antibody-positive samples improved specificity in the three species. Thirty one animals were classified as confirmed infected, based on necropsy and laboratory results, and 27/31 were antibody positive on Stat-Pak for an estimated sensitivity of 87.1%. The study findings indicate that rapid serologic tests used in series are comparable to the SCT and CCT and may have a greater ability to detect TB-infected cervids. PMID:22792512
A unit for inspection of materials using differential gamma-ray scattering technique
NASA Astrophysics Data System (ADS)
Chankow, Nares; Pojchanachai, Saraparn
2004-01-01
The main objectives of this research were to develop a prototype unit using the differential gamma-ray scattering technique (DGST) and to demonstrate its possible use in nondestructive inspection of materials. The unit consisted of a 5 mCi (185 MBq) 137Cs gamma-ray source positioned perpendicularly to a 5 cm × 5 cm BGO detector. The gamma-ray beam was collimated by a 5 cm thick lead collimator with 1 cm ∅ opening while the detector was only side shielded allowing scattered gamma-rays to reach the detector from different angles. The unit was then tested with 20 cm × 20 cm × 20 cm concrete mortar containing four rebars at its corners. It was found that the integral of the differential spectrum changed corresponding to the size and position of the rebar which was in front of the source and the detector. It was also found that the integral of the differential spectrum increased with increasing degree of corrosion of the rebar. The results indicated that a portable DGST unit could be designed to be used as a tool in nondestructive inspection but the interpretation of the differential spectrum still needs further investigation.
Hepatitis C virus in sickle cell disease.
Hassan, Mohamed; Hasan, Syed; Giday, Samuel; Alamgir, Laila; Banks, Alpha; Frederick, Winston; Smoot, Duane; Castro, Oswaldo
2003-01-01
PURPOSE: To determine the prevalence of hepatitis C virus antibodies (anti-HCV) in patients with sickle cell disease. PATIENTS AND METHODS: Between 1983 and 2001, 150 patients from the Howard University Hospital Center for Sickle Cell Disease were screened for HCV antibody (52% women, 48% men, mean age 34 years). Frozen serum samples from 56 adult sickle cell patients who had participated in previous surveys (1983-92) of HIV and HTLV-1 serology and who were tested in 1992 for anti-HCV antibody--when commercial ELISA test (Ortho) became available--were included in this paper. Of the 150 patients in the study, 132 had sickle cell anemia genotype (SS), 15 had sickle cell hemoglobin-C disease (SC) and three had sickle beta thalassemia. Clinical charts were reviewed for history of blood transfusion, IV drug abuse, homosexuality, tattooing, iron overload, and alcohol abuse. RESULTS: Antibodies to HCV were detected in 53 patients (35.3%). Of the 55 patients who had frozen serum samples tested in 1992, 32 (58%) were reactive for anti-HCV, while only 21 of the 95 patients (22%) tested after 1992 were positive for HCV antibodies (P<0.001). Thirty-nine of 77 patients (51%) who received more than 10 units of packed red blood cells were positive for HCV antibody, and only 14 of 61 patients (23%) who received less than 10 units of packed red blood cells transfusion were positive for HCV antibodies (P<0.001). None of the 12 patients who never received transfusion were positive for HCV antibody. In the 53 anti-HCV positive patients, the mean alanine amino-transferase (ALT) value was 98- and 81 U/L, respectively, for males and females. These values were normal for the HCV-antibody negative patients. The aspartate amino-transferase (AST) and the total bilirubin were also higher in the anti-HCV positive patients compared to patients in the anti-HCV negative group. Forty-four patients (57.1%) who were transfused more than 10 units developed iron overload defined by a serum ferritin level higher than 1,000 ng/ml. A total of 20 of the patients with iron overload underwent liver biopsies. Seven of these 20 patients (35%) were HCV positive. These patients often had more severe liver disease and higher degree of iron deposition. CONCLUSION: The prevalence of HCV antibody and iron overload is directly related to the number of blood transfusions in patients with sickle cell disease. The prevalence of HCV infection has decreased significantly, since blood donor screening for HCV became available. Chronic HCV infection and iron overload place sickle cell patients at risk for significant liver disease. PMID:14620705
Barbosa Júnior, Walter Lins; Ramos de Araújo, Paulo Sérgio; Dias de Andrade, Luiz; Aguiar Dos Santos, Ana Maria; Lopes da Silva, Maria Almerice; Dantas-Torres, Filipe; Medeiros, Zulma
2015-11-01
After the emergence of the human immunodeficiency virus (HIV)/acquired immunodeficiency syndrome (AIDS), the number of visceral leishmaniasis (VL)-HIV/AIDS coinfections has increased worldwide. Herein, we assessed the usefulness of an rK39-based immunochromatographic test (rK39 ICT) (DiaMed-IT LEISH(®); DiaMed AG, Cressier-sur-Morat, Switzerland) and a latex agglutination test (KAtex; Kalon Biological, Guildford, United Kingdom) for urinary antigen detection to diagnose VL in 15 HIV/AIDS patients from northeastern Brazil. VL diagnosis was based on clinical findings, cytology, serology, parasite DNA, and/or urinary antigen detection. VL was confirmed in seven out of 15 HIV/AIDS patients. Only three patients were positive in bone marrow cytology, three patients were conventional polymerase chain reaction (PCR) positive, while six were real-time PCR positive. All patients were direct agglutination test (DAT) (Royal Tropical Institute, Amsterdam, The Netherlands) positive; of these, four were positive by rK39 ICT and five by KAtex. Large-scale studies are needed to validate the use of the KAtex in the national public health laboratory network in Brazil, aiming at improving the diagnosis of VL in HIV/AIDS patients in this country. © The American Society of Tropical Medicine and Hygiene.
IUSThrust Vector Control (TVC) servo system
NASA Technical Reports Server (NTRS)
Conner, G. E.
1979-01-01
The IUS TVC SERVO SYSTEM which consists of four electrically redundant electromechanical actuators, four potentiometer assemblies, and two controllers to provide movable nozzle control on both IUS solid rocket motors is developed. An overview of the more severe IUS TVC servo system design requirements, the system and component designs, and test data acquired on a preliminary development unit is presented. Attention is focused on the unique methods of sensing movable nozzle position and providing for redundant position locks.
Moritz, Erin D; Tonnetti, Laura; Hewins, Mary Ellen; Berardi, Victor P; Dodd, Roger Y; Stramer, Susan L
2017-07-01
Blood donation screening detecting only antibodies fails to identify donors in the earliest stage of infection, before a detectable immunologic response, that is, the "window period" (WP). We present data on WP donations identified during prospective screening for Babesia microti, a transfusion-transmissible parasite of increasing concern in the United States. Blood donations collected in Connecticut, Massachusetts, Minnesota, and Wisconsin were screened using polymerase chain reaction (PCR) and arrayed fluorescence immunoassay (AFIA) to detect B. microti DNA and antibodies, respectively. Parasite loads were estimated using quantitative PCR. Red blood cell (RBC) samples were inoculated into hamsters to assess infectivity. Donors screening reactive were indefinitely deferred, tested by supplemental methods, and followed to assess DNA and antibody clearance. Demographic data from WP donors (i.e., those screening PCR positive and AFIA negative) were compared to data from other positive donors. Of 220,479 donations screened from June 2012 to August 2016, a total of 700 were positive, of which 15 (2% of positive donations or 1 per 14,699 screened donations) were confirmed WP donations. The median estimated parasite load in WP donations was 350 parasites/mL, no different than AFIA-positive and PCR-positive donors. Parasite loads in RBC samples from WP units ranged from 14 to 11,022 parasites/mL; RBC samples from three of 10 (30%) WP donations infected hamsters. The mean age of WP donors was 48 years (range, 17-75 years); three (20%) were female. WP donor demographics did not differ significantly from demographics of other donors. We report one per 15,000 B. microti WP infections in blood donors in endemic areas, demonstrating the importance of nucleic acid testing to mitigate the risk of transfusion-transmitted babesiosis. © 2017 AABB.
Ferrando, Carlos; Romero, Carolina; Tusman, Gerardo; Suarez-Sipmann, Fernando; Canet, Jaume; Dosdá, Rosa; Valls, Paola; Villena, Abigail; Serralta, Ferran; Jurado, Ana; Carrizo, Juan; Navarro, Jose; Parrilla, Cristina; Romero, Jose E; Pozo, Natividad; Soro, Marina; Villar, Jesús; Belda, Francisco Javier
2017-05-29
To assess the diagnostic accuracy of peripheral capillary oxygen saturation (SpO 2 ) while breathing room air for 5 min (the 'Air-Test') in detecting postoperative atelectasis. Prospective cohort study. Diagnostic accuracy was assessed by measuring the agreement between the index test and the reference standard CT scan images. Postanaesthetic care unit in a tertiary hospital in Spain. Three hundred and fifty patients from 12 January to 7 February 2015; 170 patients scheduled for surgery under general anaesthesia who were admitted into the postsurgical unit were included. The Air-Test was performed in conscious extubated patients after a 30 min stabilisation period during which they received supplemental oxygen therapy via a venturi mask. The Air-Test was defined as positive when SpO 2 was ≤96% and negative when SpO 2 was ≥97%. Arterial blood gases were measured in all patients at the end of the Air-Test. In the subsequent 25 min, the presence of atelectasis was evaluated by performing a CT scan in 59 randomly selected patients. The primary study outcome was assessment of the accuracy of the Air-Test for detecting postoperative atelectasis compared with the reference standard. The secondary outcome was the incidence of positive Air-Test results. The Air-Test diagnosed postoperative atelectasis with an area under the receiver operating characteristic curve of 0.90 (95% CI 0.82 to 0.98) with a sensitivity of 82.6% and a specificity of 87.8%. The presence of atelectasis was confirmed by CT scans in all patients (30/30) with positive and in 5 patients (17%) with negative Air-Test results. Based on the Air-Test, postoperative atelectasis was present in 36% of the patients (62 out of 170). The Air-Test may represent an accurate, simple, inexpensive and non-invasive method for diagnosing postoperative atelectasis. NCT02650037. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Impaired limb position sense after stroke: a quantitative test for clinical use.
Carey, L M; Oke, L E; Matyas, T A
1996-12-01
A quantitative measure of wrist position sense was developed to advance clinical measurement of proprioceptive limb sensibility after stroke. Test-retest reliability, normative standards, and ability to discriminate impaired and unimpaired performance were investigated. Retest reliability was assessed over three sessions, and a matched-pairs study compared stroke and unimpaired subjects. Both wrists were tested, in counterbalanced order. Patients were tested in hospital-based rehabilitation units. Reliability was investigated on a consecutive sample of 35 adult stroke patients with a range of proprioceptive discrimination abilities and no evidence of neglect. A consecutive sample of 50 stroke patients and convenience sample of 50 healthy volunteers, matched for age, sex, and hand dominance, were tested in the normative-discriminative study. Age and sex were representative of the adult stroke population. The test required matching of imposed wrist positions using a pointer aligned with the axis of movement and a protractor scale. The test was reliable (r = .88 and .92) and observed changes of 8 degrees can be interpreted, with 95% confidence, as genuine. Scores of healthy volunteers ranged from 3.1 degrees to 10.9 degrees average error. The criterion of impairment was conservatively defined as 11 degrees (+/-4.8 degrees) average error. Impaired and unimpaired performance were well differentiated. Clinicians can confidently and quantitatively sample one aspect of proprioceptive sensibility in stroke patients using the wrist position sense test. Development of tests on other joints using the present approach is supported by our findings.
Spence Laschinger, Heather K; Finegan, Joan; Wilk, Piotr
2011-01-01
Unit-level leadership and structural empowerment play key roles in creating healthy work environments, yet few researchers have examined these contextual effects on nurses' well-being. The aim of this study was to test a multilevel model of structural empowerment examining the effect of nursing unit leadership quality and structural empowerment on nurses' experiences of burnout and job satisfaction and to examine the effect of a personal dispositional variable, core self-evaluation, on these nurse experiences. Nurses (n = 3,156) from 217 hospital units returned surveys that included measures of leader-member exchange, structural empowerment, burnout, core self-evaluation, and job satisfaction. Multilevel structural equation modeling was used to test the model. Nurses' shared perceptions of leader-member exchange quality on their units positively influenced their shared perceptions of unit structural empowerment (Level 2), which resulted in significantly higher levels of individual nurse job satisfaction (Level 1). Unit-level leader-member exchange quality also directly influenced individual nurse job satisfaction. Unit leader-member exchange quality and structural empowerment influenced emotional exhaustion and cynicism differentially. Higher unit-level leader-member exchange quality was associated with lower cynicism; higher unit-level structural empowerment was associated with lower emotional exhaustion. At Level 1, higher core self-evaluation was associated with lower levels of both emotional exhaustion and cynicism, both of which were associated with lower job satisfaction. This study provides a theoretical understanding of how unit leadership affects both unit- and individual-level outcomes.
Desai, Vinit M; Roberts, Karlene H; Ciavarelli, Anthony P
2006-01-01
The association between accidents and subsequent work unit safety perceptions was assessed to address cognitive and behavioral changes following accidents. Many studies attempt to predict accident rates using measures of work unit safety, but effects vary considerably. Conversely, this study examined whether recent accidents may be positively associated with work unit safety perceptions, as suggested by behavioral learning mechanisms (increases in safety investments following accidents) or cognitive mechanisms (defensive attributions regarding accident causality). Lagged squadron-level accident experience was correlated with work unit safety perceptions obtained through a 61-question safety climate survey administered to 6,361 individuals in U.S. Navy flight squadrons. Positive associations between minor or intermediately severe accidents and future safety climate scores were found, although no effect was found for major accidents. We suggest that accident history should be considered when examining work unit safety perceptions because recent accidents may be associated with higher safety climate scores. We did not find that this varies systematically with accident severity, and longitudinal research on additional samples is needed to further test this possibility. This research may be used to refine measurement of work unit safety and to examine impacts of accidents or safety violations on workers' cognitive processes and group behavioral changes.
Hoskyns, E W; Simpson, H; Monk, P
1994-10-01
BCG vaccination alters the response to tuberculin testing and influences the potential validity of the Heaf test in the diagnosis of tuberculosis. This study used a purified protein derivative 1 tuberculin unit (TU) Mantoux test with a cut off of 5 mm induration as an indicator of tuberculous infection in high risk children to determine whether this would distinguish infection from previous neonatal BCG vaccination. Children at high risk of tuberculosis on chest radiography, Heaf test, or contact history who had been screened in the contact tracing clinic and referred for further assessment were included in the study. After clinical examination, chest radiography, and Mantoux testing they were assigned to three groups (tuberculous disease, chemoprophylaxis, or no treatment) and followed up for 6-24 months in the outpatient clinic and subsequently by postal questionnaire. Comparison of the Heaf and Mantoux tests showed a difference in the results with 82% of cases positive by the Heaf test and 59% positive by the Mantoux test. Using the Mantoux test result in combination with clinical and radiographic findings 194 children were allocated to the three groups as follows: primary tuberculosis (5), chemoprophylaxis (101), no treatment (88). During follow up for a mean (range) time of 46 (11-102) months four additional cases received treatment for primary tuberculosis, two in the chemoprophylaxis group and two in the untreated group. The use of the 1 TU Mantoux test after neonatal BCG vaccination reduced the number of children receiving treatment from 129 to 93-that is, by 36%. Although the numbers are small, there was no increase in the later development of tuberculosis.
VLT deformable secondary mirror: integration and electromechanical tests results
NASA Astrophysics Data System (ADS)
Biasi, R.; Andrighettoni, M.; Angerer, G.; Mair, C.; Pescoller, D.; Lazzarini, P.; Anaclerio, E.; Mantegazza, M.; Gallieni, D.; Vernet, E.; Arsenault, R.; Madec, P.-Y.; Duhoux, P.; Riccardi, A.; Xompero, M.; Briguglio, R.; Manetti, M.; Morandini, M.
2012-07-01
The VLT Deformable secondary is planned to be installed on the VLT UT#4 as part of the telescope conversion into the Adaptive Optics test Facility (AOF). The adaptive unit is based on the well proven contactless, voice coil motor technology that has been already successfully implemented in the MMT, LBT and Magellan adaptive secondaries, and is considered a promising technical choice for the forthcoming ELT-generation adaptive correctors, like the E-ELT M4 and the GMT ASM. The VLT adaptive unit has been recently assembled after the completion of the manufacturing and modular test phases. In this paper, we present the most relevant aspects of the system integration and report the preliminary results of the electromechanical tests performed on the unit. This test campaign is a typical major step foreseen in all similar systems built so far: thanks to the metrology embedded in the system, that allows generating time-dependent stimuli and recording in real time the position of the controlled mirror on all actuators, typical dynamic response quality parameters like modal settling time, overshoot and following error can be acquired without employing optical measurements. In this way the system dynamic and some aspect of its thermal and long term stability can be fully characterized before starting the optical tests and calibrations.
Markovich, Jessica E; Stucker, Karla M; Carr, Alaina H; Harbison, Carole E; Scarlett, Janet M; Parrish, Colin R
2012-07-01
To estimate the prevalence of canine parvovirus (CPV) strains among dogs with enteritis admitted to a referral hospital in the southwestern United States during an 11-month period and to compare diagnostic test results, disease severity, and patient outcome among CPV strains. Prospective observational study. 72 dogs with histories and clinical signs of parvoviral enteritis. For each dog, a fecal sample or rectal swab specimen was evaluated for CPV antigen via an ELISA. Subsequently, fecal samples (n = 42 dogs) and pharyngeal swab specimens (16) were obtained and tested for CPV antigen via an ELISA and CPV DNA via a PCR assay. For specimens with CPV-positive results via PCR assay, genetic sequencing was performed to identify the CPV strain. 56 dogs tested positive for CPV via ELISA or PCR assay. For 42 fecal samples tested via both ELISA and PCR assay, 27 had positive results via both assays, whereas 6 had positive PCR assay results only. Ten pharyngeal swab specimens yielded positive PCR assay results. Genetic sequencing was performed on 34 fecal or pharyngeal swab specimens that had CPV-positive PCR assay results; 25 (73.5%) were identified as containing CPV type-2c, and 9 (26.5%) were identified as containing CPV type-2b. No association was found between CPV strain and disease severity or clinical outcome. CPV type-2b and CPV type-2c posed similar health risks for dogs; therefore, genetic sequencing of CPV does not appear necessary for clinical management of infected patients. The diagnostic tests used could detect CPV type-2c.
First Zika-positive donations in the continental United States.
Galel, Susan A; Williamson, Phillip C; Busch, Michael P; Stanek, Danielle; Bakkour, Sonia; Stone, Mars; Lu, Kai; Jones, Scott; Rossmann, Susan N; Pate, Lisa Lee
2017-03-01
Zika virus (ZIKV) has spread in the Americas, including parts of the southern United States, and infection can be associated with serious complications, including congenital brain abnormalities. Probable transfusion transmission of ZIKV has been documented in Brazil. Preemptive testing of blood donations for ZIKV RNA was implemented in southern US states at risk of local transmission using a test approved under a Food and Drug Administration (FDA) investigational new drug application, cobas Zika. Screening was expanded after issuance of an updated FDA guidance. Donations reactive on initial screening were further tested by nucleic acid and antibody tests to determine the donor status. Of 358,786 donations from US states screened by individual donation testing, 23 were initially reactive on cobas Zika. Fourteen of these represented probable ZIKV infection based on reactivity on additional nucleic acid testing or anti-Zika immunoglobulin M. Ten of the 14 donors reported travel to an identified ZIKV-active area within 90 days before donation (median time from end of travel to donation, 25 days; range, 6-71 days). Three donors with travel history also had a potential sexual exposure. Only seven of the 14 donations with probable ZIKV infection were detectable upon 1:6 dilution to simulate minipool testing. The estimated specificity of the cobas Zika test was 99.997%. Screening of donations for ZIKV RNA can interdict ZIKV-infected donors. Donor risk factors include travel more than 4 weeks before donation and sexual exposure. Minipool screening would have detected only 50% of the RNA-positive donations. © 2017 The Authors Transfusion published by Wiley Periodicals, Inc. on behalf of AABB.
Ilha, Marcia; Woldemeskel, Moges; Berghaus, Roy D; Pence, Mel E
2014-01-01
Objectives: Leptospirosis is one of the most widespread zoonotic infectious diseases affecting humans and animals. Several animal species, including cattle, can act as potential asymptomatic carriers facilitating zoonotic transmission of Leptospira. This study was conducted to assess the occurrence of asymptomatic renal Leptospira carriers among cattle slaughtered in southeastern Georgia, United States. Methods: A battery of diagnostic tests, including dark field microscopy, direct fluorescent antibody staining, polymerase chain reaction, and culture, were performed on a set of bovine kidneys (n = 37) collected from an abattoir in southeastern Georgia, United States. Virulence of a field isolate obtained from this study was tested in a hamster experimental model. Results: Motile spirochete-like structures were observed by dark field microscopy in 23 (59%) out of 37 kidney samples tested. In all, 29 samples (78%) were positive by direct fluorescent antibody staining. Only 11 (29.7%) samples by polymerase chain reaction and 3 (8.1%) by culture were positive for Leptospira sp. The isolates obtained by culture were confirmed as Leptospira borgpetersenii. Hamsters experimentally infected with one of the Leptospira field isolates obtained from this study did not show clinical signs but developed renal infection with interstitial nephritis and tubular necrosis. Conclusions: This study confirms that asymptomatic Leptospira renal infection is present among cattle in the region. Our findings underscore the need for future studies to assess the potential environmental contamination and transmission to humans in contact with infected cattle. PMID:26770734
40 CFR 63.925 - Test methods and procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... Each potential leak interface (i.e., a location where organic vapor leakage could occur) on the cover... secured in the closed position. (3) The detection instrument shall meet the performance criteria of Method... in the unit, not for each individual organic constituent. (4) The detection instrument shall be...
40 CFR 63.945 - Test methods and procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., appendix A. Each potential leak interface (i.e., a location where organic vapor leakage could occur) on the... devices shall be secured in the closed position. (3) The detection instrument shall meet the performance... material placed in the unit, not for each individual organic constituent. (4) The detection instrument...
40 CFR 63.905 - Test methods and procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... Each potential leak interface (i.e., a location where organic vapor leakage could occur) on the cover... secured in the closed position. (3) The detection instrument shall meet the performance criteria of Method... in the unit, not for each individual organic constituent. (4) The detection instrument shall be...
General Beliefs and Environmental Concern: Transatlantic Comparisons
ERIC Educational Resources Information Center
Olofsson, Anna; Ohman, Susanna
2006-01-01
The aim of the study was to empirically test whether grouping people according to their general beliefs, combined with positional factors, can explain environmental concern, and whether there are country differences in this respect. The study is based on the United States, Canadian, Norwegian, and Swedish parts of The International Social Survey…
Choi, Eun Ha; Kim, Eun-Kyung; Kim, Pil Bong
2018-03-31
EDUCATIONAL LEADERSHIP OF NURSING UNIT MANAGERS ON TEAM EFFECTIVENESS: Mediating Effects of Organizational Communication Satisfaction. This study identifies the effects of the educational leadership of nursing unit managers on team effectiveness and the mediating effects of organizational communication satisfaction; it highlights the importance of educational leadership and organizational communication and provides the data needed to enhance the education capacity of managers. The participants were 216 nursing unit managers of staff nurses at a tertiary hospital located in C Region, South Korea, and nurses who had worked for more than six months at the same hospital. This study was conducted using questionnaires on educational leadership, team effectiveness, and organizational communication satisfaction. Data analysis was performed with a t-test, ANOVA, Scheffé, Pearson's correlation coefficient, and simple and multiple regression analyses using SPSS version 23.0. Mediation analysis was tested using Baron and Kenny's regression analysis and a Sobel test. The mean score for the educational leadership of nursing unit managers was 3.74(±0.68); for organizational communication satisfaction, 3.14(±0.51); and for team effectiveness, 3.52(±0.49). Educational leadership was significantly positively correlated with team effectiveness and organizational communication satisfaction. Organizational communication satisfaction demonstrated a complete mediating effect on the relationship between educational leadership and team effectiveness (β=.61, p<.001) and was significant (Sobel test; Z=7.40, p<.001). The results indicate that the educational leadership of nursing unit managers increases communication satisfaction among nurses; this supports the idea that educational leadership can contribute to team effectiveness. This suggests that the educational leadership and communication capacity of nursing unit managers must be improved to enhance the performance of nursing organizations. Copyright © 2018. Published by Elsevier B.V.
Pathogenic lineage of Perkinsea associated with mass mortality of frogs across the United States
Isidoro Ayza, Marcos; Lorch, Jeffrey M.; Grear, Daniel A.; Winzeler, Megan; Calhoun, Daniel L.; Barichivich, William J.
2017-01-01
Emerging infectious diseases such as chytridiomycosis and ranavirus infections are important contributors to the worldwide decline of amphibian populations. We reviewed data on 247 anuran mortality events in 43 States of the United States from 1999–2015. Our findings suggest that a severe infectious disease of tadpoles caused by a protist belonging to the phylum Perkinsea might represent the third most common infectious disease of anurans after ranavirus infections and chytridiomycosis. Severe Perkinsea infections (SPI) were systemic and led to multiorganic failure and death. The SPI mortality events affected numerous anuran species and occurred over a broad geographic area, from boreal to subtropical habitats. Livers from all PCR-tested SPI-tadpoles (n = 19) were positive for the Novel Alveolate Group 01 (NAG01) of Perkinsea, while only 2.5% histologically normal tadpole livers tested positive (2/81), suggesting that subclinical infections are uncommon. Phylogenetic analysis demonstrated that SPI is associated with a phylogenetically distinct clade of NAG01 Perkinsea. These data suggest that this virulent Perkinsea clade is an important pathogen of frogs in the United States. Given its association with mortality events and tendency to be overlooked, the potential role of this emerging pathogen in amphibian declines on a broad geographic scale warrants further investigation.
Differential GPS for air transport: Status
NASA Technical Reports Server (NTRS)
Hueschen, Richard M.
1993-01-01
The presentation presents background on what the Global Navigation Satellite System (GNSS) is, desired target dates for initial GNSS capabilities for aircraft operations, and a description of differential GPS (Global Positioning System). The presentation also presents an overview of joint flight tests conducted by LaRC and Honeywell on an integrated differential GPS/inertial reference unit (IRU) navigation system. The overview describes the system tested and the results of the flight tests. The last item presented is an overview of a current grant with Ohio University from LaRC which has the goal of developing a precision DGPS navigation system based on interferometry techniques. The fundamentals of GPS interferometry are presented and its application to determine attitude and heading and precision positioning are shown. The presentation concludes with the current status of the grant.
Surges of advanced medical support associated with influenza outbreaks.
King, J C; Schweinle, J E; Hatchett, R J; Gao, Y; Lichenstein, R; Zhou, J
2017-08-01
We utilized de-identified data to evaluate increases in four outcomes during influenza outbreak periods (IOPs) including: hospitalization, intensive care unit admission, mechanical ventilation or death for adults aged 18 years or older with medically attended acute respiratory illnesses (MAARI) admitted to any of Maryland's 50 acute-care hospitals over 12 years. Weekly numbers of positive influenza tests in the Maryland area were obtained from the US Center for Disease Control and Prevention interactive website. The fewest consecutive weeks around the peak week containing at least 85% of the positive tests defined the IOP. Weekly counts of individual study outcomes were positively correlated with regional weekly counts of positive influenza tests during all the IOPs over 12 years. Also, rate ratios comparing daily occurrences of each study outcome between the IOP and non-IOP were significantly elevated. These results confirm conclusions of previous studies that influenza outbreaks are clearly associated with deaths and increased use of advanced medical resources by patients with MAARI. These data analyses suggest that increased efforts to develop more effective influenza vaccines and therapeutics should be a priority.
Detilleux, J; Theron, L; Duprez, J-N; Reding, E; Moula, N; Detilleux, M; Bertozzi, C; Hanzen, C; Mainil, J
2016-08-01
Milk losses associated with mastitis can be attributed to either effects of pathogens per se (i.e. direct losses) or to effects of the immune response triggered by the presence of mammary pathogens (i.e. indirect losses). Test-day milk somatic cell counts (SCC) and number of bacterial colony forming units (CFU) found in milk samples are putative measures of the level of immune response and of the bacterial load, respectively. Mediation models, in which one independent variable affects a second variable which, in turn, affects a third one, are conceivable models to estimate direct and indirect losses. Here, we evaluated the feasibility of a mediation model in which test-day SCC and milk were regressed toward bacterial CFU measured at three selected sampling dates, 1 week apart. We applied this method on cows free of clinical signs and with records on up to 3 test-days before and after the date of the first bacteriological samples. Most bacteriological cultures were negative (52.38%), others contained either staphylococci (23.08%), streptococci (9.16%), mixed bacteria (8.79%) or were contaminated (6.59%). Only losses mediated by an increase in SCC were significantly different from null. In cows with three consecutive bacteriological positive results, we estimated a decreased milk yield of 0.28 kg per day for each unit increase in log2-transformed CFU that elicited one unit increase in log2-transformed SCC. In cows with one or two bacteriological positive results, indirect milk loss was not significantly different from null although test-day milk decreased by 0.74 kg per day for each unit increase of log2-transformed SCC. These results highlight the importance of milk losses that are mediated by an increase in SCC during mammary infection and the feasibility of decomposing total milk loss into its direct and indirect components.
Malka, Shachar; Hawkins, Michelle G; Jones, James H; Pascoe, Peter J; Kass, Philip H; Wisner, Erik R
2009-09-01
To determine the effects of body position on lung and air-sac volumes in anesthetized and spontaneously breathing red-tailed hawks (Buteo jamaicensis). 6 adult red-tailed hawks (sex unknown). A crossover study design was used for quantitative estimation of lung and air-sac volumes in anesthetized hawks in 3 body positions: dorsal, right lateral, and sternal recumbency. Lung volume, lung density, and air-sac volume were calculated from helical computed tomographic (CT) images by use of software designed for volumetric analysis of CT data. Effects of body position were compared by use of repeated-measures ANOVA and a paired Student t test. Results for all pairs of body positions were significantly different from each other. Mean +/- SD lung density was lowest when hawks were in sternal recumbency (-677 +/- 28 CT units), followed by right lateral (-647 +/- 23 CT units) and dorsal (-630 +/- 19 CT units) recumbency. Mean lung volume was largest in sternal recumbency (28.6 +/- 1.5 mL), followed by right lateral (27.6 +/- 1.7 mL) and dorsal (27.0 +/- 1.5 mL) recumbency. Mean partial air-sac volume was largest in sternal recumbency (27.0 +/- 19.3 mL), followed by right lateral (21.9 +/- 16.1 mL) and dorsal (19.3 +/- 16.9 mL) recumbency. In anesthetized red-tailed hawks, positioning in sternal recumbency resulted in the greatest lung and air-sac volumes and lowest lung density, compared with positioning in right lateral and dorsal recumbency. Additional studies are necessary to determine the physiologic effects of body position on the avian respiratory system.
Anderson, Peter; Coulton, Simon; Kaner, Eileen; Bendtsen, Preben; Kłoda, Karolina; Reynolds, Jillian; Segura, Lidia; Wojnar, Marcin; Mierzecki, Artur; Deluca, Paolo; Newbury-Birch, Dorothy; Parkinson, Kathryn; Okulicz-Kozaryn, Katarzyna; Drummond, Colin; Gual, Antoni
2017-01-01
PURPOSE We aimed to test whether 3 strategies—training and support, financial reimbursement, and an option to direct screen-positive patients to an Internet-based method of giving brief advice—have a longer-term effect on primary care clinicians’ delivery of screening and advice to heavy drinkers operationalized with the Alcohol Use Disorders Identification Test–Consumption (AUDIT-C) tool. METHODS We undertook a cluster randomized factorial trial with a 12-week implementation period in 120 primary health care units throughout Catalonia, England, Netherlands, Poland, and Sweden. Units were randomized to 8 groups: care as usual (control); training and support alone; financial reimbursement alone; electronic brief advice alone; paired combinations of these conditions; and all 3 combined. The primary outcome was the proportion of consulting adult patients (aged 18 years and older) receiving intervention—screening and, if screen-positive, advice—at 9 months. RESULTS Based on the factorial design, the ratio of the log of the proportion of patients given intervention at the 9-month follow-up was 1.39 (95% CI, 1.03–1.88) in units that received training and support as compared with units that did not. Neither financial reimbursement nor directing screen-positive patients to electronic brief advice led to a higher proportion of patients receiving intervention. CONCLUSIONS Training and support of primary health care units has a lasting, albeit small, impact on the proportion of adult patients given an alcohol intervention at 9 months. PMID:28694269
Gyre and gimble: a maximum-likelihood replacement for Patterson correlation refinement.
McCoy, Airlie J; Oeffner, Robert D; Millán, Claudia; Sammito, Massimo; Usón, Isabel; Read, Randy J
2018-04-01
Descriptions are given of the maximum-likelihood gyre method implemented in Phaser for optimizing the orientation and relative position of rigid-body fragments of a model after the orientation of the model has been identified, but before the model has been positioned in the unit cell, and also the related gimble method for the refinement of rigid-body fragments of the model after positioning. Gyre refinement helps to lower the root-mean-square atomic displacements between model and target molecular-replacement solutions for the test case of antibody Fab(26-10) and improves structure solution with ARCIMBOLDO_SHREDDER.
Positive tuberculin skin tests in nursing home residents in Southern Taiwan.
Chang, Chia-Ming; Lee, Nan-Yao; Lee, Hsin-Chun; Wu, Chi-Jung; Chen, Po-Lin; Lee, Ching-Chi; Shih, Hsin-I; Ko, Wen-Chien
2010-01-01
In Taiwan, the tuberculin skin test (TST) is not recommended as a screening test for Mycobacterium tuberculosis (TB) infections. The aim of this study is to determine the prevalence and predictors of positive tuberculin reactivity and its association with TB infections among nursing home residents in Taiwan. A cross-sectional study and review of medical records were conducted at four nursing homes in Tainan City. A one-stage TST was performed by study nurses using two tuberculin units of purified protein derivative (PPD) of the RT23 strain. An induration ≥10 mm at 72 h was considered to be a positive reaction. Chest radiographs, acid-fast stains and mycobacterial cultures of three sputum samples were performed for those with a positive TST result. Of 115 residents (66.5% participation, mean age 73.1 years) who underwent a TST, 26 (22.6%) had a positive reaction. One woman was microbiologically diagnosed to have pulmonary TB. On multivariate analysis, a Bacille Calmette-Guérin (BCG) scar and a history of myocardial infarction were significantly associated with a positive TST. In conclusions, this study shows a considerable rate of positive TST among nursing home residents in southern Taiwan. A BCG scar and a history of myocardial infarction were associated with a positive TST. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
SIRU utilization. Volume 1: Theory, development and test evaluation
NASA Technical Reports Server (NTRS)
Musoff, H.
1974-01-01
The theory, development, and test evaluations of the Strapdown Inertial Reference Unit (SIRU) are discussed. The statistical failure detection and isolation, single position calibration, and self alignment techniques are emphasized. Circuit diagrams of the system components are provided. Mathematical models are developed to show the performance characteristics of the subsystems. Specific areas of the utilization program are identified as: (1) error source propagation characteristics and (2) local level navigation performance demonstrations.
Saini, Devashish; Mazza, Giovanni; Shah, Najaf; Mirza, Muzna; Gori, Mandar M; Nandigam, Hari Krishna; Orthner, Helmuth F
2006-01-01
Response times for pre-hospital emergency care may be improved with the use of algorithms that analyzes historical patterns in incident location and suggests optimal places for prepositioning of emergency response units. We will develop such an algorithm based on cluster analysis and test whether it leads to significant improvement in mileage when compared to actual historical data of dispatching based on fixed stations. PMID:17238702
SU-F-J-37: Commissioning a Six Degree of Freedom Couch
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roberts, D; Lam, K; Bredfeldt, J
2016-06-15
Purpose: The proper operation of a six degree of freedom couch (6DOFC) to position a patient for treatment requires that a number systems on the treatment unit work together correctly. Commissioning a 6DOFC requires not only the commissioning of each separate system but also commissioning the interactions between the systems. Methods: To commission a 6DOFC, we tested the resolvers that readout the linear and angular positions; the orthogonality of the axes of the laser positioning system, the imaging system, the gantry and the couch as well as their relationship to each other. An automated Winston-Lutz test was used verify themore » coincidence of the origins of the laser system, imaging system and treatment unit. The IsoCal phantom was used to verify the consistency of axes orientations between systems. The operation of the couch and imaging system was verified under simulated load conditions and an end to end test was performed to verify correct operation of the system. Results: The tests on the couch resolvers, orthogonality and coincidence of the axes of each system were successfully completed and showed excellent agreement. The automated Winston-Lutz test showed that the maximum displacement of the center of the radiation field with respect to the isocenter was <0.6 mm (radius) at isocenter. The analysis of the IsoCal phantom showed that the maximum variation of the radiation field with respect to known locations in the phantom was ∼0.9 mm for all the BBs in the phantom. Load tests showed maximum errors of 1 mm. Conclusion: We tested all system associated with the 6DOFC and found the uncertainty due to imaging was <.9mm and the uncertainty due to loading ∼1 mm, resulting in a total error of ∼1.4 mm.« less
How do strategic decisions and operative practices affect operating room productivity?
Peltokorpi, Antti
2011-12-01
Surgical operating rooms are cost-intensive parts of health service production. Managing operating units efficiently is essential when hospitals and healthcare systems aim to maximize health outcomes with limited resources. Previous research about operating room management has focused on studying the effect of management practices and decisions on efficiency by utilizing mainly modeling approach or before-after analysis in single hospital case. The purpose of this research is to analyze the synergic effect of strategic decisions and operative management practices on operating room productivity and to use a multiple case study method enabling statistical hypothesis testing with empirical data. 11 hypotheses that propose connections between the use of strategic and operative practices and productivity were tested in a multi-hospital study that included 26 units. The results indicate that operative practices, such as personnel management, case scheduling and performance measurement, affect productivity more remarkably than do strategic decisions that relate to, e.g., units' size, scope or academic status. Units with different strategic positions should apply different operative practices: Focused hospital units benefit most from sophisticated case scheduling and parallel processing whereas central and ambulatory units should apply flexible working hours, incentives and multi-skilled personnel. Operating units should be more active in applying management practices which are adequate for their strategic orientation.
Stress and anxiety effects on positive skin test responses in young adults with allergic rhinitis.
Heffner, Kathi L; Kiecolt-Glaser, Janice K; Glaser, Ronald; Malarkey, William B; Marshall, Gailen D
2014-07-01
Anxiety and psychological stress affect allergy-related immune function. How these relations influence the evaluations of patients with allergic rhinitis is unknown. To examine whether anxiety and stress exposure affect skin prick test (SPT) responses to common allergens for which patients with atopy showed no prior positive SPT response. Patients with allergic rhinitis, evidenced by clinical history and SPT results, were admitted twice to a hospital research unit for 4 hours. In a crossover design, SPT wheals were assessed before and after the Trier Social Stress Test and then the following morning; for comparison, SPT wheals were assessed before and after a laboratory session without a stressor. Analyses focused on wheal responses for common allergens that tested negative (wheal size <3 mm larger than saline) from SPTs performed at multiple baseline assessments. After the Trier Social Stress Test, more anxious patients with atopy had a higher incidence of positive SPT reactions to antigens that previously tested negative. Anxiety was unrelated to positive SPT incidence under nonstressful conditions. Based on clinical symptom reports, newly positive SPT reactions after the stressor were apparently corrections of previously false-negative SPT reactions. The SPT wheal responses for allergens previously testing negative were enhanced after a stressor. Histamine (positive control) or saline (negative control) SPT responses were not affected. A laboratory stressor affected allergen SPT responses in more anxious patients with allergic rhinitis. In addition to clinical history, assessment of anxiety and current stress at the time of the SPT may provide valuable information about a patient's allergic status and aid in clinical decision making. Copyright © 2014 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Diagnostic accuracy of blood centers in the screening of blood donors for viral markers
Dogbe, Elliot Eli; Arthur, Fareed
2015-01-01
Introduction Blood transfusion still remains a life saving intervention in almost all healthcare facilities worldwide. Screening of blood donors/blood units is done in almost every blood bank facility before the blood units/blood components are transfused to prevent transfusion-transmissible infections. The kind of testing kits or the methods used by a facility and the technical expertise of the personnel greatly affects the screening results of a facility. This study was aimed at evaluating the diagnostic accuracy of five hospital-based blood bank testing facilities (Komfo Anokye Teaching Hospital KNUST, Kwame Nkrumah University of Science and Technology, Agogo, Bekwai and Sunyani) that used rapid immunochromatograhic assays (RIA) in screening blood donors/blood units in Ghana. Methods Blood samples (300) from the five testing facilities and their screening results for hepatitis B surface antigen (HBsAg), antibodies to hepatitis C virus (HCV) and human immunodeficiency virus (HIV) using RIAs were obtained. All the samples were then analysed for the three viral markers using 3rd generational enzyme linked immunosorbent assay (ELISA) kit as the gold standard. Results The mean false positive for HBsAg was 2.2% with Bekwai testing facility having the highest of 4.4%. For HCV, the mean false positive was 2.8% with Agogo and Bekwai testing facilities having the highest of 8.7% respectively. For HIV screening, the mean false positive was 11.1% with Bekwai testing facility having the highest of 28.0%. The mean false negative for the facilities were 3.0% for HBV, 75.0% for HCV and 0.0% for HIV with KATH having the highest of 6.3% for HBV, Bekwai having the highest of 100% for HCV and no facility showing false negative for HIV. Mean sensitivity of the screening procedure for the facilities was 97.0%, 25.0% and 100.0% whilst the mean specificity was 97.8%, 97.2% and 88.9% for HBV, HCV and HIV respectively. Statistical comparison among the testing facilities showed no significant differences among the various testing centres for HBV screening; however, significant differences were obtained for HCV and HIV screening. Conclusion This study has shown that there is no standardised screening procedure for blood bank testing facilities in the country. There is therefore an urgent need for an internal and external control body to oversee screening procedures in blood banks across the country. PMID:26090067
Toxocariasis in children attending a Public Health Service Pneumology Unit in Paraná State, Brazil.
Guilherme, Edson V; Marchioro, Ariella A; Araujo, Silvana M; Falavigna, Dina Lúcia Morais; Adami, Carolina; Falavigna-Guilherme, Gustavo; Rubinsky-Elefant, Guita; Falavigna-Guilherme, Ana Lucia
2013-01-01
The enzyme-linked immunosorbent assay (ELISA) is the most widely used tool to detect anti-Toxocara IgG antibodies for both serodiagnostic and seroepidemiological surveys on human toxocariasis. In the last eight years a high prevalence of toxocariasis (32.2-56.0%) has been reported in children attending public health units from municipalities in the state of Paraná, Brazil. Therefore, the aim of this work was to compare the frequency found among the general child population with that of children attending a public pneumology service in Maringá, Paraná, Brazil and describe the laboratorial, clinical and epidemiological findings. The research was conducted at the Consórcio Público Intermunicipal de Saúde do Setentrião Paranaense (CISAMUSEP) from July 2009 to July 2010 among children aged between one and 15 years. From a total of 167 children studied, only 4.2% (7/167) tested positive for anti-Toxocara spp. IgG antibodies and presented mild eosinophilia (2/7), increased serum IgE levels (6/7) and a positive allergy test for mites (5/7). The presence of pets (dogs or cats) at home did not correlate with the seroprevalence. In conclusion, cases of toxocariasis involving the respiratory tract are rare in children attending a public health pneumology unit in the northwestern region of Paraná State, despite the high prevalence of this type of toxocariasis among the infantile population attending Basic Health Units in the same geographical area.
Vogler, Ingridt Hildegard; Saito, Mariza; Spinosa, Adriana Aparecida; da Silva, Marilza Celina; Munhoz, Egberto; Reiche, Edna Maria Vissoci
2011-01-01
Background For transfusion purposes, blood donors must be accepted both in clinical and serological evaluations and must not have excluded their own donation using the confidential unit exclusion. Aim The objective of this study was to verify whether blood donors who choose self exclusion are more likely to be positive in serological tests than donors who do not. Methods A cross-sectional analysis was carried out of 51,861 consecutive whole blood donations from January 2004 to December 2008 at a public blood bank in Londrina, Southern Brazil. Results Self exclusion was chosen in 1672 (3.2%) donations, most frequently by first-time blood donors (p-value < 0.0001), by blood donors from external collections (p-value < 0.0001), by men (p value < 0.0001) and by under 30-year-old donors (p-value < 0.0001). The frequency of positive serology was 5.3% in the group that chose self exclusion and 3.5% in the group that did not choose self exclusion (p-value < 0.0001). Conclusions These results show that confidential unit exclusion used in this blood bank is effective and is inexpensive. However, the diagnostic power to detect blood-borne infections was low and resulted in the discard of a high number of blood bags without any direct or indirect serologic markers of pathogens. The use of confidential unit exclusion could be replaced with molecular tests to screen blood donors. PMID:23049338
Mixed messages: presentation of information in cystic fibrosis-screening pamphlets.
Loeben, G L; Marteau, T M; Wilfond, B S
1998-01-01
Written pamphlets are an important source of information for individuals deciding whether to undergo carrier testing for cystic fibrosis (CF). Adequate understanding of the condition and reproductive options following the diagnosis of a fetus with CF are critical to informed decision making. The information given about CF and reproductive options in 28 pamphlets about carrier testing, from commercial and noncommercial organizations in the United States and the United Kingdom, aimed at prenatal and other populations, was assessed. The amount of information provided about CF showed a range of 1-37 sentences (median 6.5), with most being relatively neutral and with a minority conveying a positive or a negative image. Positive sentences were less common in British, U.S. commercial, and prenatal pamphlets. Statements about life expectancy also varied considerably, both in the ages provided and in the degree of optimism conveyed. In addition, the pamphlets varied in the amount of information they provided about reproductive options following the diagnosis of a fetus with CF. Abortion was mentioned in just 15 pamphlets, more often in the United Kingdom than in the United States and more frequently in pamphlets from noncommercial than in those from commercial organizations. Wide variation in the descriptions of CF and the reproductive options presented raises concerns about the extent to which any one pamphlet may present balanced information. The choices about what information to include in educational materials need to be explicitly considered on the basis of the message intended to be sent. PMID:9758594
Mixed messages: presentation of information in cystic fibrosis-screening pamphlets.
Loeben, G L; Marteau, T M; Wilfond, B S
1998-10-01
Written pamphlets are an important source of information for individuals deciding whether to undergo carrier testing for cystic fibrosis (CF). Adequate understanding of the condition and reproductive options following the diagnosis of a fetus with CF are critical to informed decision making. The information given about CF and reproductive options in 28 pamphlets about carrier testing, from commercial and noncommercial organizations in the United States and the United Kingdom, aimed at prenatal and other populations, was assessed. The amount of information provided about CF showed a range of 1-37 sentences (median 6.5), with most being relatively neutral and with a minority conveying a positive or a negative image. Positive sentences were less common in British, U.S. commercial, and prenatal pamphlets. Statements about life expectancy also varied considerably, both in the ages provided and in the degree of optimism conveyed. In addition, the pamphlets varied in the amount of information they provided about reproductive options following the diagnosis of a fetus with CF. Abortion was mentioned in just 15 pamphlets, more often in the United Kingdom than in the United States and more frequently in pamphlets from noncommercial than in those from commercial organizations. Wide variation in the descriptions of CF and the reproductive options presented raises concerns about the extent to which any one pamphlet may present balanced information. The choices about what information to include in educational materials need to be explicitly considered on the basis of the message intended to be sent.
Melchor, J C; Navas, H; Marcos, M; Iza, A; De Diego, M; Rando, D; Melchor, I; Burgos, J
2018-05-01
To compare the performance of the placental alpha microglobulin-1 (PAMG-1) and fetal fibronectin (fFN) tests for the prediction of spontaneous preterm delivery in patients presenting to an emergency obstetric unit with threatened preterm labor, by conducting a retrospective audit of patient medical records from separate 1-year periods during which either fFN or PAMG-1 was used as the standard-of-care biochemical test. This was a retrospective cohort study based on chart review of electronic medical records of women with threatened preterm labor presenting at a level-III maternity hospital over two different periods: (1) the 'baseline' period (year 2012), during which the qualitative fFN test with a cut-off of 50 ng/mL was used as the standard-of-care biochemical test for the risk assessment of preterm delivery, and (2) the 'comparative' period (year 2016), during which the PAMG-1 test with a cut-off of 1 ng/mL was used as the standard-of-care biomarker test. Patients with a singleton pregnancy between 24 + 0 and 34 + 6 weeks' gestation with symptoms of early preterm labor, clinically intact membranes and cervical dilatation < 3 cm, who did not have a medically indicated preterm delivery within 14 days of testing, were selected for chart review and included in the analysis. Key parameters used for the analysis were biochemical test results, time of testing and time of delivery. Positive predictive value (PPV), negative predictive value (NPV), sensitivity, specificity, and positive and negative likelihood ratios (LR+ and LR-) for the prediction of spontaneous preterm delivery ≤ 7 and ≤ 14 days of presentation were calculated for the PAMG-1 and fFN tests. Four hundred and twenty patients were identified as having presented with threatened preterm labor during the baseline period, of whom 378 (90.0%) met the eligibility criteria. Of these, 38 (10.1%) were fFN positive and 10 (2.6%) had spontaneous preterm delivery ≤ 7 days of presentation. PPV, NPV, LR+ and LR- of fFN were 7.9%, 97.9%, 3.2 and 0.8, respectively, for spontaneous preterm delivery ≤ 7 days. Four hundred and ten patients were identified as having presented with threatened preterm labor during the comparative period and 367 (89.5%) subjects met the eligibility criteria. Of these, 17 (4.6%) were PAMG-1 positive and 12 (3.3%) had spontaneous preterm delivery ≤ 7 days of presentation. PAMG-1 PPV and NPV were 35.3% and 98.3%, respectively, and LR+ and LR- were 16.1 and 0.5, respectively, for spontaneous preterm delivery ≤ 7 days. Before switching to PAMG-1, fFN was the standard-of-care test for the risk assessment of spontaneous preterm delivery. This retrospective audit of each test's performance over separate 1-year periods shows that we were more than twice as likely to get a positive fFN test than a positive PAMG-1 test, while the rate of discharging women who ultimately delivered spontaneously within 14 days of testing was not affected. Furthermore, a positive PAMG-1 test was more than four times more reliable than a positive fFN test in predicting imminent spontaneous preterm delivery. The use of a more reliable biomarker that is associated with fewer false-positive results could lead to a reduction in unnecessary admissions, interventions and use of hospital resources. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.
Advanced Stirling Convertor Dynamic Test Approach and Results
NASA Technical Reports Server (NTRS)
Meer, David W.; Hill, Dennis; Ursic, Joseph
2009-01-01
The U.S. Department of Energy (DOE), Lockheed Martin (LM), and NASA Glenn Research Center (GRC) have been developing the Advanced Stirling Radioisotope Generator (ASRG) for use as a power system for space science missions. As part of the extended operation testing of this power system, the Advanced Stirling Converters (ASC) at NASA John H. Glenn Research Center undergo a vibration test sequence intended to simulate the vibration history of an ASC used in an ASRG for a space mission. This sequence includes testing at Workmanship and Flight Acceptance levels interspersed with periods of extended operation to simulate pre and post fueling. The final step in the test sequence utilizes additional testing at Flight Acceptance levels to simulate launch. To better replicate the acceleration profile seen by an ASC incorporated into an ASRG, the input spectra used in testing the convertors was modified based on dynamic testing of the ASRG Engineering Unit ( ASRG-EU) at Lockheed Martin. This paper presents the vibration test plan for current and future ASC units, including the modified input spectra, and the results of recent tests using these spectra. The test results include data from several accelerometers mounted on the convertors as well as the piston position and output power variables.
HIV testing for acute medical admissions: evaluation of a pilot study in Leicester, England.
Palfreeman, Adrian; Nyatsanza, Farai; Farn, Helen; McKinnon, Graham; Schober, Paul; McNally, Paul
2013-06-01
The 2008 UK National Guidelines for HIV testing recommended HIV testing should be offered to all general medical admissions aged 16-60 years in high prevalence areas, and that this should be evaluated to ensure this was effective in diagnosing previously undiagnosed HIV. HIV testing was introduced as a routine test for all patients admitted to the acute medical admissions unit, comparisons were made between the testing rates before, during and after this intervention. The pilot was initiated in August 2009. Prior to the pilot the unit was carrying out 15 tests per month. However, when the pilot was introduced 82 tests were being carried out per month with a total of 10 new diagnoses since the start of the pilot. The proportion of patients tested versus those eligible for testing remained low varying between 6% and 22% month by month. 10 patients we found to be HIV positive with a prevalence of approximately 1%, 10 fold higher than the cut off for cost effectiveness used in the guidelines. Overall the pilot showed that HIV testing could be delivered without the use of extra resources and is acceptable to patients.
Effect of genomic drift of influenza PCR tests.
Stellrecht, Kathleen A; Nattanmai, Seela M; Butt, Jumshan; Maceira, Vincente P; Espino, Alvin A; Castro, Allan J; Landes, Allen; Dresser, Nicolas; Butt, Shafiq A
2017-08-01
Nucleic acid amplification assays have become the method of choice for influenza (Flu) testing due to superior accuracy and faster turnaround time. Although assays are designed to detect highly conserved genomic targets, mutations can influence test sensitivity. Most of the circulating viruses in the United States during the 2014-2015 season were associated with significant genetic drift; however, the effect on testing was unknown. We compared the performance of Prodesse ProFlu+/ProFAST+ (PFlu/PFAST), FilmArray Respiratory Panel (RP), cobas ® Influenza A/B test (cIAB), and Xpert ® Flu (Xpt) in a retrospective analysis of consecutive nasopharyngeal specimens received for a two-week period during the winter of 2015. Furthermore, limits of detection (LOD) were determined with six isolates of Flu. Of the 275 specimens, 63 were positive for FluA by PFAST, 60 were positive by RP, 58 were positive by cIAB and 52 were positive by Xpt. Only a subset of 135 specimens was tested by PFlu, of which 32 were positive. The sensitivity/specificity for PFAST, RP, cIAB, Xpt and PFlu was 100/99.1%, 96.7/99.5%, 91.8/99.1%, 85.2%/100%, and 75.6%/98.9%, respectively. LOD analyses demonstrated assay performance variations were strain associated. Specifically, PFlu's and cIAB's LODs were higher with A/Texas/50/2012-like and A/Switzerland/9715293/2013-like strains, while Xpt's highest LOD was with the Swiss strain. Strain-associated assay performance variation is known to occur with other Flu test methods; hence, it is not surprising that such variation would be observed with molecular tests. Careful monitoring and reporting for strain-associated variances are warranted for all test methods. Copyright © 2017 Elsevier B.V. All rights reserved.
Nymo, Ingebjørg Helena; Beckmen, Kimberlee; Godfroid, Jacques
2016-01-01
We used an indirect enzyme-linked immunosorbent assay (iELISA) and the rose bengal test (RBT) to test for anti-Brucella antibodies in moose (Alces alces gigas), muskoxen (Ovibos moschatus), and plains bison (Bison bison bison) from various game management units (GMUs) in Alaska, US, sampled from 1982 to 2010. A portion of the sera had previously been tested with the standard plate test (SPT), the buffered Brucella antigen (BBA) card test, and the card test (CARD). No antibody-positive plains bison were identified. Anti-Brucella antibodies were detected in moose (iELISA, n=4/87; RBT, n=4/87; SPT, n=4/5; BBA, n=4/4) from GMU 23 captured in 1992, 1993, and 1995 and in muskoxen (iELISA, n=4/52; RBT, n=4/52; CARD, n=4/35) from GMUs 26A and 26B captured in 2004, 2006, and 2007. A negative effect of infection on the health of individuals of these species is probable. The presence of antibody-positive animals from 1992 to 2007 suggests presence of brucellae over time. The antibody-positive animals were found in northern Alaska, an area with a historically higher prevalence of Brucella-positive caribou, and a spillover of Brucella suis biovar 4 from caribou may have occurred. Brucella suis biovar 4 causes human brucellosis, and transmission from consumption of moose and muskoxen is possible.
Drach-Zahavy, Anat; Trogan, Revital
2013-10-01
This study embraced a unit-level diversity perspective to examine interpersonal aggression, as experienced or witnessed by individual team members. Specifically, our aim was to explore the moderating role of a unit's diversity climate in the link between unit-level surface diversity in terms of ethnicity, sex, age, and tenure, and individual-level perceptions of interpersonal aggression. We tested our hypotheses with 30 nursing units using the Mixed-Linear Model procedure appropriate for nested samples. Results demonstrated that diversity climate moderated the relationships between tenure and ethnic unit diversity and interpersonal aggression, experienced or witnessed among individual team members. Moreover, regardless of the level of diversity climate, age diversity was positively linked to interpersonal aggression, whereas sex diversity was negatively linked to it. These findings imply that the unit's context affects interpersonal aggression and provides important theoretical and practical implications to proactively prevent interpersonal aggression.
Muralidharan, Sidharth; Men, Linjuan Rita
2015-10-01
Based on consumer socialization theory, this study proposes and tests a conceptual model of social media shopping behavior, which links the antecedents of user motivations of engagement and peer communication about products to shopping behavior through social media. A cross-cultural survey was conducted with social media users in two culturally distinct markets with the largest Internet population: China (n=304) and the United States (n=328). Findings showed that social interaction, information, and remuneration were positive antecedents of peer communication for users from both countries. Peer communication positively impacted social media shopping behavior, and cultural differences were observed, with social interaction being important to Chinese users' shopping behavior, while remuneration was more important to American users. Implications are discussed.
Nikolaidis, Pantelis T; Clemente, Filipe M; van der Linden, Cornelis M I; Rosemann, Thomas; Knechtle, Beat
2018-01-01
The objectives of the present study were to examine the validity and reliability of the 10 Hz Johan GPS unit in assessing in-line movement and change of direction. The validity was tested against the criterion measure of 200 m track-and-field (track-and-field athletes, n = 8) and 20 m shuttle run endurance test (female soccer players, n = 20). Intra-unit and inter-unit reliability was tested by intra-class correlation coefficient (ICC) and coefficient of variation (CV), respectively. An analysis of variance examined differences between the GPS measurement and five laps of 200 m at 15 km/h, and t -test examined differences between the GPS measurement and 20 m shuttle run endurance test. The difference between the GPS measurement and 200 m distance ranged from -0.13 ± 3.94 m (95% CI -3.42; 3.17) in the first lap to 2.13 ± 2.64 m (95% CI -0.08; 4.33) in the fifth lap. A good intra-unit reliability was observed in 200 m (ICC = 0.833, 95% CI 0.535; 0.962). Inter-unit CV ranged from 1.31% (fifth lap) to 2.20% (third lap). The difference between the GPS measurement and 20 m shuttle run endurance test ranged from 0.33 ± 4.16 m (95% CI -10.01; 10.68) in 11.5 km/h to 9.00 ± 5.30 m (95% CI 6.44; 11.56) in 8.0 km/h. A moderate intra-unit reliability was shown in the second and third stage of the 20 m shuttle run endurance test (ICC = 0.718, 95% CI 0.222;0.898) and good reliability in the fifth, sixth, seventh and eighth (ICC = 0.831, 95% CI -0.229;0.996). Inter-unit CV ranged from 2.08% (11.5 km/h) to 3.92% (8.5 km/h). Based on these findings, it was concluded that the 10 Hz Johan system offers an affordable valid and reliable tool for coaches and fitness trainers to monitor training and performance.
Test results of the STI GPS time transfer receiver
NASA Technical Reports Server (NTRS)
Hall, D. L.; Handlan, J.; Wheeler, P.
1983-01-01
Global time transfer, or synchronization, between a user clock and USNO UTC time can be performed using the Global Positioning System (GPS), and commercially available time transfer receivers. This paper presents the test results of time transfer using the GPS system and a Stanford Telecommunications, Inc. (STI) Time Transfer System (TTS) Model 502. Tests at the GPS Master Control Site (MCS) in Vandenburg, California and at the United States Naval Observatory (USNO) in Washington, D.C. are described. An overview of GPS, and the STI TTS 502 is presented. A discussion of the time transfer process and test concepts is included.
Legionella spp. in dental unit waterlines.
Sedlata Juraskova, E; Sedlackova, H; Janska, J; Holy, O; Lalova, I; Matouskova, I
2017-01-01
To determine the current presence of Legionella spp. in the output water of dental unit waterlines (DUWLs) and examine its mitigation by disinfection at the Institute of Dentistry and Oral Sciences, Faculty of Medicine and Dentistry, Palacky University Olomouc and University Hospital Olomouc. The first stage of our survey involved collecting samples of DUWL output water from 50 dental chair units (DCUs), and 2 samples of the incoming potable water. In October 2015, a one-time disinfection (1 % Stabimed) of DUWLs was conducted. This was followed by collecting 10 control samples (survey stage 2). From the total of 50 samples (survey stage 1), 18 samples (36.0 %) tested positive for Legionella spp. Following the disinfection, nine of the ten samples no longer showed any presence of Legionella. Based on culture results, the one-time disinfection (1 % Stabimed) was effective. We are unable to comment on the duration of positive effect of disinfection on the occurrence of Legionella spp. in the outlet water. It was a one-time survey (Tab. 2, Ref. 32).
LED Curing Lights and Temperature Changes in Different Tooth Sites
Armellin, E.; Bovesecchi, G.; Coppa, P.; Pasquantonio, G.; Cerroni, L.
2016-01-01
Objectives. The aim of this in vitro study was to assess thermal changes on tooth tissues during light exposure using two different LED curing units. The hypothesis was that no temperature increase could be detected within the dental pulp during polymerization irrespective of the use of a composite resin or a light-curing unit. Methods. Caries-free human first molars were selected, pulp residues were removed after root resection, and four calibrated type-J thermocouples were positioned. Two LED lamps were tested; temperature measurements were made on intact teeth and on the same tooth during curing of composite restorations. The data was analyzed by one-way analysis of variance (ANOVA), Wilcoxon test, Kruskal-Wallis test, and Pearson's χ 2. After ANOVA, the Bonferroni multiple comparison test was performed. Results. Polymerization data analysis showed that in the pulp chamber temperature increase was higher than that without resin. Starlight PRO, in the same condition of Valo lamp, showed a lower temperature increase in pre- and intrapolymerization. A control group (without composite resin) was evaluated. Significance. Temperature increase during resin curing is a function of the rate of polymerization, due to the exothermic polymerization reaction, the energy from the light unit, and time of exposure. PMID:27195282
LED Curing Lights and Temperature Changes in Different Tooth Sites.
Armellin, E; Bovesecchi, G; Coppa, P; Pasquantonio, G; Cerroni, L
2016-01-01
Objectives. The aim of this in vitro study was to assess thermal changes on tooth tissues during light exposure using two different LED curing units. The hypothesis was that no temperature increase could be detected within the dental pulp during polymerization irrespective of the use of a composite resin or a light-curing unit. Methods. Caries-free human first molars were selected, pulp residues were removed after root resection, and four calibrated type-J thermocouples were positioned. Two LED lamps were tested; temperature measurements were made on intact teeth and on the same tooth during curing of composite restorations. The data was analyzed by one-way analysis of variance (ANOVA), Wilcoxon test, Kruskal-Wallis test, and Pearson's χ (2). After ANOVA, the Bonferroni multiple comparison test was performed. Results. Polymerization data analysis showed that in the pulp chamber temperature increase was higher than that without resin. Starlight PRO, in the same condition of Valo lamp, showed a lower temperature increase in pre- and intrapolymerization. A control group (without composite resin) was evaluated. Significance. Temperature increase during resin curing is a function of the rate of polymerization, due to the exothermic polymerization reaction, the energy from the light unit, and time of exposure.
Bautista-Arredondo, Sergio; Sosa-Rubí, Sandra G.; Opuni, Marjorie; Contreras-Loya, David; Kwan, Ada; Chaumont, Claire; Chompolola, Abson; Condo, Jeanine; Galárraga, Omar; Martinson, Neil; Masiye, Felix; Nsanzimana, Sabin; Ochoa-Moreno, Ivan; Wamai, Richard; Wang’ombe, Joseph
2016-01-01
Objective: We estimate facility-level average annual costs per client along the HIV testing and counselling (HTC) and prevention of mother-to-child transmission (PMTCT) service cascades. Design: Data collected covered the period 2011–2012 in 230 HTC and 212 PMTCT facilities in Kenya, Rwanda, South Africa, and Zambia. Methods: Input quantities and unit prices were collected, as were output data. Annual economic costs were estimated from the service providers’ perspective using micro-costing. Average annual costs per client in 2013 United States dollars (US$) were estimated along the service cascades. Results: For HTC, average cost per client tested ranged from US$5 (SD US$7) in Rwanda to US$31 (SD US$24) in South Africa, whereas average cost per client diagnosed as HIV-positive ranged from US$122 (SD US$119) in Zambia to US$1367 (SD US$2093) in Rwanda. For PMTCT, average cost per client tested ranged from US$18 (SD US$20) in Rwanda to US$89 (SD US$56) in South Africa; average cost per client diagnosed as HIV-positive ranged from US$567 (SD US$417) in Zambia to US$2021 (SD US$3210) in Rwanda; average cost per client on antiretroviral prophylaxis ranged from US$704 (SD US$610) in South Africa to US$2314 (SD US$3204) in Rwanda; and average cost per infant on nevirapine ranged from US$888 (SD US$884) in South Africa to US$2359 (SD US$3257) in Rwanda. Conclusion: We found important differences in unit costs along the HTC and PMTCT service cascades within and between countries suggesting that more efficient delivery of these services is possible. PMID:27753679
AIDS: a challenge for the public health.
Acheson, E D
1986-03-22
While the number of cases of acquired immunodeficiency syndrome (AIDS) has been increasing worldwide, the incidence in the United Kingdom (UK) is substantially lower than in the United States (US) and several other European countries. In the UK and US, the infection is confined largely to homosexual and bisexual men, persons who abuse drugs by injection, hemophiliacs, and sexual partners of members of these groups, including heterosexual men and women. Public education must focus on methods of transmission and control of the disease. The efficacy of testing for antibodies to the HTLV-III infection is questionable because there is no cure at present. Issues of confidentiality and denial of insurance or other support to persons who test positive must be considered.
Carrique-Mas, J J; Breslin, M; Snow, L; Arnold, M E; Wales, A; McLaren, I; Davies, R H
2008-11-01
A follow-on study was carried out on 23 holdings identified as Salmonella positive in the 2004/2005 European Union (EU) baseline survey of Salmonella in laying hens. Eleven of 13 cage and 4/7 floor houses remained positive for Salmonella when the new flock was tested, and from 10/13 cage and 3/7 floor houses a Salmonella of the same serovar/phage type as found in the EU survey was isolated. There was a high correlation between the level of contamination in the houses at the time of the EU survey and in the follow-on flock. On seven occasions the house identified as positive in the EU survey was sampled after cleaning and disinfection but before a new flock was placed, and in all of them Salmonella could be isolated from the houses. The observed number of infected houses in infected holdings suggests that the holding-level prevalence in the United Kingdom would be about 21% higher than the results obtained in the EU survey.
CARRIQUE-MAS, J. J.; BRESLIN, M.; SNOW, L.; ARNOLD, M. E.; WALES, A.; McLAREN, I.; DAVIES, R. H.
2008-01-01
SUMMARY A follow-on study was carried out on 23 holdings identified as Salmonella positive in the 2004/2005 European Union (EU) baseline survey of Salmonella in laying hens. Eleven of 13 cage and 4/7 floor houses remained positive for Salmonella when the new flock was tested, and from 10/13 cage and 3/7 floor houses a Salmonella of the same serovar/phage type as found in the EU survey was isolated. There was a high correlation between the level of contamination in the houses at the time of the EU survey and in the follow-on flock. On seven occasions the house identified as positive in the EU survey was sampled after cleaning and disinfection but before a new flock was placed, and in all of them Salmonella could be isolated from the houses. The observed number of infected houses in infected holdings suggests that the holding-level prevalence in the United Kingdom would be about 21% higher than the results obtained in the EU survey. PMID:18177519
Napoli, Anthony M
2014-04-01
Cardiology consensus guidelines recommend use of the Diamond and Forrester (D&F) score to augment the decision to pursue stress testing. However, recent work has reported no association between pretest probability of coronary artery disease (CAD) as measured by D&F and physician discretion in stress test utilization for inpatients. The author hypothesized that D&F pretest probability would predict the likelihood of acute coronary syndrome (ACS) and a positive stress test and that there would be limited yield to diagnostic testing of patients categorized as low pretest probability by D&F score who are admitted to a chest pain observation unit (CPU). This was a prospective observational cohort study of consecutively admitted CPU patients in a large-volume academic urban emergency department (ED). Cardiologists rounded on all patients and stress test utilization was driven by their recommendations. Inclusion criteria were as follows: age>18 years, American Heart Association (AHA) low/intermediate risk, nondynamic electrocardiograms (ECGs), and normal initial troponin I. Exclusion criteria were as follows: age older than 75 years with a history of CAD. A D&F score for likelihood of CAD was calculated on each patient independent of patient care. Based on the D&F score, patients were assigned a priori to low-, intermediate-, and high-risk groups (<10, 10 to 90, and >90%, respectively). ACS was defined by ischemia on stress test, coronary artery occlusion of ≥70% in at least one vessel, or elevations in troponin I consistent with consensus guidelines. A true-positive stress test was defined by evidence of reversible ischemia and subsequent angiographic evidence of critical stenosis or a discharge diagnosis of ACS. An estimated 3,500 patients would be necessary to have 1% precision around a potential 0.3% event rate in low-pretest-probability patients. Categorical comparisons were made using Pearson chi-square testing. A total of 3,552 patients with index visits were enrolled over a 29-month period. The mean (±standard deviation [SD]) age was 51.3 (±9.3) years. Forty-nine percent of patients received stress testing. Pretest probability based on D&F score was associated with stress test utilization (p<0.01), risk of ACS (p<0.01), and true-positive stress tests (p=0.03). No patients with low pretest probability were subsequently diagnosed with ACS (95% CI=0 to 0.66%) or had a true-positive stress test (95% CI=0 to 1.6%). Physician discretionary decision-making regarding stress test use is associated with pretest probability of CAD. However, based on the D&F score, low-pretest-probability patients who meet CPU admission criteria are very unlikely to have a true-positive stress test or eventually receive a diagnosis of ACS, such that observation and stress test utilization may be obviated. © 2014 by the Society for Academic Emergency Medicine.
Wolf, R; Barkema, H W; De Buck, J; Orsel, K
2016-06-01
Mycobacterium avium ssp. paratuberculosis (MAP), the causative agent of Johne's disease, is present on most dairy farms in Alberta, causing economic losses and presenting a potential public health concern. The objective of this cross-sectional study was to identify risk factors for Alberta dairy herds being MAP-positive based on environmental samples (ES). Risk assessments were conducted and ES were collected on 354 Alberta dairy farms (62% of eligible producers) voluntarily participating in the Alberta Johne's Disease Initiative. In univariate logistic regression, risk factors addressing animal and pen hygiene, as well as the use of feeding equipment to remove manure and manure application on pastures, were all associated with the number of positive ES. Furthermore, based on factor analysis, risk factors were clustered and could be summarized as 4 independent factors: (1) animal, pen, and feeder contamination; (2) shared equipment and pasture contamination; (3) calf diet; and (4) cattle purchase. Using these factor scores as independent variables in multivariate logistic regression models, a 1-unit increase in animal, pen, and feeder contamination resulted in 1.31 times higher odds of having at least 1 positive ES. Furthermore, a 1-unit increase in cattle purchase also resulted in 1.31 times the odds of having at least 1 positive ES. Finally, a 100-cow increase in herd size resulted in an odds ratio of 2.1 for having at least 1 positive ES. In conclusion, cleanliness of animals, pens, and feeders, as well as cattle purchase practices, affected risk of herd infection with MAP. Therefore, improvements in those management practices should be the focus of effective tools to control MAP on dairy farms. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Risk management, or just a different risk?
Freer, Y; Lyon, A
2006-01-01
Background National reporting of adverse incidents has resulted in a number of clinical alerts being issued. Despite a lack of evidence, these alerts are often accompanied by a mandatory requirement to alter practice. There is likely to be clinician resistance to such a method of change management, particularly where evidence of safety is missing. Aim To determine the level of implementation within neonatal units of an alert requiring the change from litmus to pH paper to test nasogastric tube position. Method A questionnaire sent to all neonatal units in the United Kingdom with more than 12 cots. Results From the 207 questionnaires sent, there were 165 (80%) responses. Fifty five percent of units were still using litmus. All continued to use supplementary tests not recommended in best practice statements issued at the time of the alert. There was considerable variation in the pH value at which it was considered safe to feed. Conclusions Nine months after the alert, more than half the units had not changed to pH paper, and supplementary methods of testing were still being used. The wide range of pH values highlights the uncertainty about the “normal” gastric pH in the newborn. The evidence that, in neonatal units, changing to pH paper is safer than the long established use of litmus is lacking. Recommendations for change in practice must be based on good information and not seen just as a “knee jerk” response to adverse incidents. PMID:16464936
Soka, Moses J; Choi, Mary J; Baller, April; White, Stephen; Rogers, Emerson; Purpura, Lawrence J; Mahmoud, Nuha; Wasunna, Christine; Massaquoi, Moses; Abad, Neetu; Kollie, Jomah; Dweh, Straker; Bemah, Philip K; Christie, Athalia; Ladele, Victor; Subah, Oneykachi C; Pillai, Satish; Mugisha, Margaret; Kpaka, Jonathan; Kowalewski, Stephen; German, Emilio; Stenger, Mark; Nichol, Stuart; Ströher, Ute; Vanderende, Kristin E; Zarecki, Shauna Mettee; Green, Hugh Henry W; Bailey, Jeffrey A; Rollin, Pierre; Marston, Barbara; Nyenswah, Tolbert G; Gasasira, Alex; Knust, Barbara; Williams, Desmond
2016-10-01
Ebola virus has been detected in semen of Ebola virus disease survivors after recovery. Liberia's Men's Health Screening Program (MHSP) offers Ebola virus disease survivors semen testing for Ebola virus. We present preliminary results and behavioural outcomes from the first national semen testing programme for Ebola virus. The MHSP operates out of three locations in Liberia: Redemption Hospital in Montserrado County, Phebe Hospital in Bong County, and Tellewoyan Hospital in Lofa County. Men aged 15 years and older who had an Ebola treatment unit discharge certificate are eligible for inclusion. Participants' semen samples were tested for Ebola virus RNA by real-time RT-PCR and participants received counselling on safe sexual practices. Participants graduated after receiving two consecutive negative semen tests. Counsellors collected information on sociodemographics and sexual behaviours using questionnaires administered at enrolment, follow up, and graduation visits. Because the programme is ongoing, data analysis was restricted to data obtained from July 7, 2015, to May 6, 2016. As of May 6, 2016, 466 Ebola virus disease survivors had enrolled in the programme; real-time RT-PCR results were available from 429 participants. 38 participants (9%) produced at least one semen specimen that tested positive for Ebola virus RNA. Of these, 24 (63%) provided semen specimens that tested positive 12 months or longer after Ebola virus disease recovery. The longest interval between discharge from an Ebola treatment unit and collection of a positive semen sample was 565 days. Among participants who enrolled and provided specimens more than 90 days since their Ebola treatment unit discharge, men older than 40 years were more likely to have a semen sample test positive than were men aged 40 years or younger (p=0·0004). 84 (74%) of 113 participants who reported not using a condom at enrolment reported using condoms at their first follow-up visit (p<0·0001). 176 (46%) of 385 participants who reported being sexually active at enrolment reported abstinence at their follow-up visit (p<0·0001). Duration of detection of Ebola virus RNA by real-time RT-PCR varies by individual and might be associated with age. By combining behavioural counselling and laboratory testing, the Men's Health Screening Program helps male Ebola virus disease survivors understand their individual risk and take appropriate measures to protect their sexual partners. World Health Organization and the US Centers for Disease Control and Prevention. ©2016 World Health Organization; licensee Elsevier. This is an Open Access article published under the CC BY 3.0 IGO license which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. In any use of this article, there should be no suggestion that WHO endorses any specific organisation, products or services. The use of the WHO logo is not permitted. This notice should be preserved along with the article's original URL.
Chronic wasting disease in free-ranging Wisconsin white-tailed deer
Joly, D.O.; Ribic, C.A.; Langenberg, J.A.; Beheler, K.; Batha, C.A.; Dhuey, B.J.; Rolley, R.E.; Bartelt, G.; VanDeelen, T.R.; Samuel, M.D.
2003-01-01
Three White-tailed Deer shot within 5 km during the 2001 hunting season in Wisconsin tested positive for chronic wasting disease, a prion disease of cervids. Subsequent sampling within 18 km showed a 3% prevalence (n=476). This discovery represents an important range extension for chronic wasting disease into the eastern United States.
ERIC Educational Resources Information Center
Abramowitz, Susan
This research paper sought to determine whether smaller sized schools decrease student alienation and increase program diversity both within the school and compared to others. Hypotheses tested were: (1) participation in small work units positively affects teacher task interdependence resulting in greater teacher interaction; (2) teacher…
Saupe, Amy A; Kaehler, Dawn; Cebelinski, Elizabeth A; Nefzger, Brian; Hall, Aron J; Smith, Kirk E
2013-08-01
Norovirus is the leading cause of foodborne disease in the United States. During October 2011-January 2013, we conducted surveillance for norovirus infection in Minnesota among callers to a complaint-based foodborne illness hotline who reported diarrhea or vomiting. Of 241 complainants tested, 127 (52.7%) were positive for norovirus.
Sapp, Sarah G H; Rascoe, Lisa N; Wilkins, Patricia P; Handali, Sukwan; Gray, Elizabeth B; Eberhard, Mark; Woodhall, Dana M; Montgomery, Susan P; Bailey, Karen L; Lankau, Emily W; Yabsley, Michael J
2016-12-01
Baylisascaris procyonis roundworms can cause potentially fatal neural larva migrans in many species, including humans. However, the clinical spectrum of baylisascariasis is not completely understood. We tested 347 asymptomatic adult wildlife rehabilitators for B. procyonis antibodies; 24 were positive, suggesting that subclinical baylisascariasis is occurring among this population.
Integrity monitoring of vehicle positioning in urban environment using RTK-GNSS, IMU and speedometer
NASA Astrophysics Data System (ADS)
El-Mowafy, Ahmed; Kubo, Nobuaki
2017-05-01
Continuous and trustworthy positioning is a critical capability for advanced driver assistance systems (ADAS). To achieve continuous positioning, methods such as global navigation satellite systems real-time kinematic (RTK), Doppler-based positioning, and positioning using low-cost inertial measurement unit (IMU) with car speedometer data are combined in this study. To ensure reliable positioning, the system should have integrity monitoring above a certain level, such as 99%. Achieving this level when combining different types of measurements that have different characteristics and different types of errors is a challenge. In this study, a novel integrity monitoring approach is presented for the proposed integrated system. A threat model of the measurements of the system components is discussed, which includes both the nominal performance and possible fault modes. A new protection level is presented to bound the maximum directional position error. The proposed approach was evaluated through a kinematic test in an urban area in Japan with a focus on horizontal positioning. Test results show that by integrating RTK, Doppler with IMU/speedometer, 100% positioning availability was achieved. The integrity monitoring availability was assessed and found to meet the target value where the position errors were bounded by the protection level, which was also less than an alert level, indicating the effectiveness of the proposed approach.
Zhu, Wenming; de Man, Tom J.B.; Avillan, Johannetsy J.; Anderson, Karen F.; Lonsway, David R.; Rowe, Lori A.; Batra, Dhwani; Rasheed, J. Kamile; Limbago, Brandi M.
2018-01-01
Oxacillinase (OXA)–48–like carbapenemases remain relatively uncommon in the United States. We performed phenotypic and genotypic characterization of 30 Enterobacteriaceae producing OXA-48–like carbapenemases that were recovered from patients during 2010–2014. Isolates were collected from 12 states and not associated with outbreaks, although we could not exclude limited local transmission. The alleles β-lactamase OXA-181 (blaOXA-181) (43%), blaOXA-232 (33%), and blaOXA-48 (23%) were found. All isolates were resistant to ertapenem and showed positive results for the ertapenem and meropenem modified Hodge test and the modified carbapenem inactivation method; 73% showed a positive result for the Carba Nordmann–Poirel test. Whole-genome sequencing identified extended-spectrum β-lactamase genes in 93% of isolates. In all blaOXA-232 isolates, the gene was on a ColKP3 plasmid. A total of 12 of 13 isolates harboring blaOXA-181 contained the insertion sequence ΔISEcp1. In all isolates with blaOXA-48, the gene was located on a TN1999 transposon; these isolates also carried IncL/M plasmids. PMID:29553324
Modified laminar flow biological safety cabinet.
McGarrity, G J; Coriell, L L
1974-10-01
Tests are reported on a modified laminar flow biological safety cabinet in which the return air plenum that conducts air from the work area to the high efficiency particulate air filters is under negative pressure. Freon gas released inside the cabinet could not be detected outside by a freon gas detection method capable of detecting 10(-6) cc/s. When T3 bacteriophage was aerosolized 5 cm outside the front opening in 11 tests, no phage could be detected inside the cabinet with the motor-filter unit in operation. An average of 2.8 x 10(5) plaque-forming units (PFU)/ft(3) (ca. 0.028 m(3)) were detected with the motor-filter unit not in operation, a penetration of 0.0%. Aerosolization 5 cm inside the cabinet yielded an average of 10 PFU/ft(3) outside the cabinet with the motor-filter unit in operation and an average of 4.1 x 10(5) PFU/ft(3) with the motor-filter unit not in operation, a penetration of 0.002%. These values are the same order of effectiveness as the positive-pressure laminar flow biological safety cabinets previously tested. The advantages of the negative-pressure return plenum design include: (i) assurance that if cracks or leaks develop in the plenum it will not lead to discharge of contaminated air into the laboratory; and (ii) the price is lower due to reduced manufacturing costs.
A Multisite Study of the Prevalence of HIV With Rapid Testing in Mental Health Settings
Blank, Michael B.; Himelhoch, Seth S.; Balaji, Alexandra B.; Metzger, David S.; Dixon, Lisa B.; Rose, Charles E.; Oraka, Emeka; Davis-Vogel, Annet; Thompson, William W.; Heffelfinger, James D.
2014-01-01
Objectives. We estimated HIV prevalence and risk factors among persons receiving mental health treatment in Philadelphia, Pennsylvania, and Baltimore, Maryland, January 2009 to August 2011. Methods. We used a multisite, cross-sectional design stratified by clinical setting. We tested 1061 individuals for HIV in university-based inpatient psychiatric units (n = 287), intensive case-management programs (n = 273), and community mental health centers (n = 501). Results. Fifty-one individuals (4.8%) were HIV-infected. Confirmed positive HIV tests were 5.9% (95% confidence interval [CI] = 3.7%, 9.4%) for inpatient units, 5.1% (95% CI = 3.1%, 8.5%) for intensive case-management programs, and 4.0% (95% CI = 2.6%, 6.1%) for community mental health centers. Characteristics associated with HIV included Black race, homosexual or bisexual identity, and HCV infection. Conclusions. HIV prevalence for individuals receiving mental health services was about 4 times as high as in the general population. We found a positive association between psychiatric symptom severity and HIV infection, indicating that engaging persons with mental illness in appropriate mental health treatment may be important to HIV prevention. These findings reinforce recommendations for routine HIV testing in all clinical settings to ensure that HIV-infected persons receiving mental health services are identified and referred to timely infectious disease care. PMID:24524493
Perets, Tsachi Tsadok; Hamouda, Dalal; Layfer, Olga; Ashorov, Olga; Boltin, Doron; Levy, Sigal; Niv, Yaron; Dickman, Ram
2017-08-01
Small intestinal bacterial overgrowth (SIBO) is defined as a bacterial count of more than 10 5 colony-forming units per milliliter in duodenal aspirate. It shares many symptoms with carbohydrate intolerance, which makes the clinical distinction of the disorders difficult. The aim of the study was to examine the relationship between a positive carbohydrate breath test and the presence of SIBO suggested by a positive lactulose hydrogen breath test. The electronic database of the gastroenterology laboratory of a tertiary medical center was searched for all patients clinically tested for SIBO in 2012-2013 for whom previous results for lactose, fructose, and/or sorbitol breath test were available. The correlation between positive findings for carbohydrate intolerance and for SIBO was statistically analyzed. The study group included 349 patients, 231 female and 118 male, of mean age 53±19 years. All had symptoms of abdominal bloating and gas. There was a statistically significant difference in rates of a positive breath test for lactose and sorbitol at ≤90 minutes between patients who were positive and negative for SIBO [χ 2 (1)=12.8, p <0.01 and χ 2 (1)=9.5, p <0.01 respectively]. Findings for fructose were not significant. There was no effect of age or gender. SIBO may represent an important reversible cause of carbohydrate intolerance. It may be especially prudent to exclude SIBO patients with an early peak (≤90 minutes) in H 2 excretion. © 2017 by the Association of Clinical Scientists, Inc.
Credit USAF, 7 September 1945. Original housed in the Muroc ...
Credit USAF, 7 September 1945. Original housed in the Muroc Flight Test Base, Unit History, 1 September 1942 - 30 June 1945. Alfred F. Simpson Historical Research Agency. United States Air Force. Maxwell AFB, Alabama. Photo captioned "Oblique view of Recreation Hall/Chapel Bldg. T73." Movies on marquee were "Why Girls Leave Home" and "Blazing the Western Trail." View looks west from camera position across E Street - Edwards Air Force Base, North Base, Recreation Hall & Chapel T-73, E Street near North Base Road, Boron, Kern County, CA
Wang, Guoshen; Mulatu, Mesfin S.; Larish, Nili
2015-01-01
Objectives. We examined HIV testing services, seropositivity, and the characteristics associated with newly identified, confirmed HIV-positive tests among transgender individuals. Methods. We analyzed data (2009–2011) using bivariate and multivariable logistic regression to examine the relationships between HIV positivity and sociodemographic and risk characteristics among male-to-female transgender individuals. Results. Most of the testing was conducted in females (51.1%), followed by males (48.7%) and transgender individuals (0.17%). Tests in male-to-female transgender individuals had the highest, newly identified confirmed HIV positivity (2.7%), followed by males (0.9%), female-to-male transgender individuals (0.5%), and females (0.2%). The associated characteristics with an HIV-positive test among male-to-female transgender individuals included ages 20 to 29 and 40 to 49 years (adjusted odds ratio [AOR] = 2.8; 95% confidence interval [CI] = 1.4, 5.6 and AOR = 2.8; 95% CI = 1.3, 5.9, respectively), African American (AOR = 4.6; 95% CI = 2.7, 7.9) or Hispanic/Latino (AOR = 2.6; 95% CI = 1.5, 4.5) race/ethnicity, and reporting sex without condom within the past year (AOR = 1.9; 95% CI = 1.3, 2.6), sex with an HIV-positive person (AOR = 1.5; 95% CI = 1.1, 2.0), or injection drug use (AOR = 2.0; 95% CI = 1.3, 3.0). Conclusions. High levels of HIV positivity among transgender individuals, particularly male-to-female transgender individuals, underscore the necessity for targeted HIV prevention services that are responsive to the needs of this population. PMID:26180964
HIV infection and awareness among men who have sex with men-20 cities, United States, 2008 and 2011.
Wejnert, Cyprian; Le, Binh; Rose, Charles E; Oster, Alexandra M; Smith, Amanda J; Zhu, Julia
2013-01-01
Over half of HIV infections in the United States occur among men who have sex with men (MSM). Awareness of infection is a necessary precursor to antiretroviral treatment and risk reduction among HIV-infected persons. We report data on prevalence and awareness of HIV infection among MSM in 2008 and 2011, using data from 20 cities participating in the 2008 and 2011 National HIV Behavioral Surveillance System (NHBS) among MSM. Venue-based, time-space sampling was used to recruit men for interview and HIV testing. We analyzed data for men who reported ≥ 1 male sex partner in the past 12 months. Participants who tested positive were considered to be aware of their infection if they reported a prior positive HIV test. We used multivariable analysis to examine differences between results from 2011 vs. 2008. HIV prevalence was 19% in 2008 and 18% in 2011 (p = 0.14). In both years, HIV prevalence was highest among older age groups, blacks, and men with lower education and income. In multivariable analysis, HIV prevalence did not change significantly from 2008 to 2011 overall (p = 0.51) or in any age or racial/ethnic category (p>0.15 in each category). Among those testing positive, a greater proportion was aware of their infection in 2011 (66%) than in 2008 (56%) (p<0.001). In both years, HIV awareness was higher for older age groups, whites, and men with higher education and income. In multivariable analysis, HIV awareness increased from 2008 to 2011 overall (p<0.001) and for all age and racial/ethnic categories (p<0.01 in each category). In both years, black MSM had the highest HIV prevalence and the lowest awareness among racial/ethnic groups. These findings suggest that HIV-positive MSM are increasingly aware of their infections.
Narrative and framing: a test of an integrated message strategy in the exercise context.
Gray, Jennifer B; Harrington, Nancy G
2011-03-01
Health communication interventions encouraging exercise may aid in mitigating the obesity crisis in the United States. Although much research has investigated behavioral predictors of exercise, little work has explored message characteristics most persuasive in the exercise context. The purpose of this study, therefore, was to test a message strategy drawing on previous work in health behavior theory combined with persuasion theories (exemplification theory and prospect theory) to encourage positive exercise attitudes, control beliefs, and intentions. The authors report the results of a controlled experiment testing messages using gain or loss frames and narrative or statistical evidence. Results indicate that gain-framed messages are significantly more successful in promoting positive exercise variables and are perceived as more effective than are loss-framed or control messages. The authors discuss the implications of the results for future research.
Clostridium difficile shows no trade-off between toxin and spore production within the human host.
Blanco, Natalia; Walk, Seth; Malani, Anurag N; Rickard, Alexander; Benn, Michele; Eisenberg, Marisa; Zhang, Min; Foxman, Betsy
2018-05-01
This study aimed to describe the correlation between Clostridium difficile spore and toxin levels within the human host. In addition, we assessed whether overgrowth of Candida albicans modified this association. We measured toxin, spore and Candida albicans levels among 200 successively collected stool samples that tested positive for C. difficile, and PCR ribotyped these C. difficile isolates. Analysis of variance and linear regression were used to test the association between spore and toxin levels. Kruskal-Wallis tests and t-tests were used to compare the association between spore or toxin levels and host, specimen, or pathogen characteristics. C. difficile toxin and spore levels were positively associated (P<0.001); this association did not vary significantly with C. albicans overgrowth [≥5 logs of C. albicans colony-forming units (c.f.u.) g -1 ]. However, ribotypes 027 and 078-126 were significantly associated with higher levels of toxin and spores, and C. albicans overgrowth. The strong positive association observed between in vivo levels of C. difficile toxin and spores suggests that patients with more severe C. difficile infections may have increased spore production, enhancing C. difficile transmission. Although, on average, spore levels were higher in toxin-positive samples than in toxin-negative/PCR-positive samples, spores were found in almost all toxin-negative samples. The ubiquity of spore production among toxin-negative and formed stool samples emphasizes the importance of following infection prevention and control measures for all C. difficile-positive patients during their entire hospital stay.
Experimental research on a modular miniaturization nanoindentation device
NASA Astrophysics Data System (ADS)
Huang, Hu; Zhao, Hongwei; Mi, Jie; Yang, Jie; Wan, Shunguang; Yang, Zhaojun; Yan, Jiwang; Ma, Zhichao; Geng, Chunyang
2011-09-01
Nanoindentation technology is developing toward the in situ test which requires miniaturization of indentation instruments. This paper presents a miniaturization nanoindentation device based on the modular idea. It mainly consists of macro-adjusting mechanism, x-y precise positioning platform, z axis precise driving unit, and the load-depth measuring unit. The device can be assembled with different forms and has minimum dimensions of 200 mm × 135 mm × 200 mm. The load resolution is about 0.1 mN and the displacement resolution is about 10 nm. A new calibration method named the reference-mapping method is proposed to calibrate the developed device. Output performance tests and indentation experiments indicate the feasibility of the developed device and calibration method. This paper gives an example that combining piezoelectric actuators with flexure hinge to realize nanoindentation tests. Integrating a smaller displacement sensor, a more compact nanoindentation device can be designed in the future.
Self-testing security sensor for monitoring closure of vault doors and the like
Cawthorne, Duane C.
1997-05-27
A self-testing device is provided for a monitoring system for monitoring whether a closure member such as a door or window is closed. The monitoring system includes a switch unit mounted on the frame of the closure member being monitored and including magnetically biased switches connected in one or more electrical monitoring circuits, and a door magnet unit mounted on the closure member being monitored. The door magnet includes one or more permanent magnets that produce a magnetic field which, when the closure member is closed, cause said switches to assume a first state. When the closure member is opened, the switches switch to a second, alarm state. The self-testing device is electrically controllable from a remote location and produces a canceling or diverting magnetic field which simulates the effect of movement of the closure member from the closed position thereof without any actual movement of the member.
Al Hosani, Farida Ismail; Pringle, Kimberly; Al Mulla, Mariam; Kim, Lindsay; Pham, Huong; Alami, Negar N; Khudhair, Ahmed; Hall, Aron J; Aden, Bashir; El Saleh, Feda; Al Dhaheri, Wafa; Al Bandar, Zyad; Bunga, Sudhir; Abou Elkheir, Kheir; Tao, Ying; Hunter, Jennifer C; Nguyen, Duc; Turner, Andrew; Pradeep, Krishna; Sasse, Jurgen; Weber, Stefan; Tong, Suxiang; Whitaker, Brett L; Haynes, Lia M; Curns, Aaron; Gerber, Susan I
2016-07-01
In January 2013, several months after Middle East respiratory syndrome coronavirus (MERS-CoV) was first identified in Saudi Arabia, Abu Dhabi, United Arab Emirates, began surveillance for MERS-CoV. We analyzed medical chart and laboratory data collected by the Health Authority-Abu Dhabi during January 2013-May 2014. Using real-time reverse transcription PCR, we tested respiratory tract samples for MERS-CoV and identified 65 case-patients. Of these patients, 23 (35%) were asymptomatic at the time of testing, and 4 (6%) showed positive test results for >3 weeks (1 had severe symptoms and 3 had mild symptoms). We also identified 6 clusters of MERS-CoV cases. This report highlights the potential for virus shedding by mildly ill and asymptomatic case-patients. These findings will be useful for MERS-CoV management and infection prevention strategies.
Al Hosani, Farida Ismail; Al Mulla, Mariam; Kim, Lindsay; Pham, Huong; Alami, Negar N.; Khudhair, Ahmed; Hall, Aron J.; Aden, Bashir; El Saleh, Feda; Al Dhaheri, Wafa; Al Bandar, Zyad; Bunga, Sudhir; Abou Elkheir, Kheir; Tao, Ying; Hunter, Jennifer C.; Nguyen, Duc; Turner, Andrew; Pradeep, Krishna; Sasse, Jurgen; Weber, Stefan; Tong, Suxiang; Whitaker, Brett L.; Haynes, Lia M.; Curns, Aaron; Gerber, Susan I.
2016-01-01
In January 2013, several months after Middle East respiratory syndrome coronavirus (MERS-CoV) was first identified in Saudi Arabia, Abu Dhabi, United Arab Emirates, began surveillance for MERS-CoV. We analyzed medical chart and laboratory data collected by the Health Authority–Abu Dhabi during January 2013–May 2014. Using real-time reverse transcription PCR, we tested respiratory tract samples for MERS-CoV and identified 65 case-patients. Of these patients, 23 (35%) were asymptomatic at the time of testing, and 4 (6%) showed positive test results for >3 weeks (1 had severe symptoms and 3 had mild symptoms). We also identified 6 clusters of MERS-CoV cases. This report highlights the potential for virus shedding by mildly ill and asymptomatic case-patients. These findings will be useful for MERS-CoV management and infection prevention strategies. PMID:27314227
Self-testing security sensor for monitoring closure of vault doors and the like
Cawthorne, D.C.
1997-05-27
A self-testing device is provided for a monitoring system for monitoring whether a closure member such as a door or window is closed. The monitoring system includes a switch unit mounted on the frame of the closure member being monitored and including magnetically biased switches connected in one or more electrical monitoring circuits, and a door magnet unit mounted on the closure member being monitored. The door magnet includes one or more permanent magnets that produce a magnetic field which, when the closure member is closed, cause said switches to assume a first state. When the closure member is opened, the switches switch to a second, alarm state. The self-testing device is electrically controllable from a remote location and produces a canceling or diverting magnetic field which simulates the effect of movement of the closure member from the closed position thereof without any actual movement of the member. 5 figs.
Washbrook, Elizabeth; Waldfogel, Jane; Bradbury, Bruce; Corak, Miles; Ghanghro, Ali Akbar
2012-01-01
In spite of important differences in some of the resources immigrant parents have to invest in their children, and in immigrant selection rules and settlement policies, there are significant similarities in the relative positions of four and five year old children of immigrants in Australia, Canada, the United Kingdom, and the United States. Children of immigrants underperform their counterparts with native-born parents in vocabulary tests, particularly if a language other than the official language is spoken at home, but are not generally disadvantaged in nonverbal cognitive domains, nor are there notable behavioral differences. These findings suggest that the cross-country differences in cognitive outcomes during the teen years documented in the existing literature are much less evident during the early years. PMID:22966925
Development of a web-based learning medium on mechanism of labour for nursing students.
Gerdprasert, Sailom; Pruksacheva, Tassanee; Panijpan, Bhinyo; Ruenwongsa, Pintip
2010-07-01
This study aimed to develop a web-based learning media on the process and mechanism of labour for the third-year university nursing and midwifery students. This media was developed based on integrating principles of the mechanism of labour with the 5Es inquiry cycle and interactive features of information technology. In this study, the web-based learning unit was used to supplement the conventional lecture as in the traditional teaching. Students' achievements were assessed by using the pre- and post-test on factual knowledge and semi-structured interviews on attitude to the unit. Supplementation with this learning unit made learning significantly more effective than the traditional lecture by itself. The students also showed positive attitude toward the learning unit. Copyright 2009 Elsevier Ltd. All rights reserved.
Balaji, Alexandra B; Oraka, Emeka; Fasula, Amy M; Jayne, Paula E; Carry, Monique G; Raiford, Jerris L
2017-03-01
Adolescents need information about sex-related topics in order to reduce risk behavior and engage in healthy sexual decision-making. Parents have the potential to be an important source of this information. Using the 2006-2010 and 2011-2013 National Survey of Family Growth, we examined associations between parent-adolescent communication before age 18 about sex-related topics and HIV testing among respondents aged 18-24 that ever had sexual intercourse (women = 3893; men = 3359). Analyses showed that for both men and women, discussing how to prevent HIV/AIDS and how to use a condom with a parent before age 18 were positively associated with HIV testing. Among women only, discussions about methods of birth control, where to get birth control, and STDs were positively associated with HIV testing. Developing strategies and interventions to facilitate parent-adolescent communication about sex-related topics, particularly HIV prevention and condom use, may be important to increase HIV testing among young women and men.
Psychosocial factors and mental work load: a reality perceived by nurses in intensive care units1
Ceballos-Vásquez, Paula; Rolo-González, Gladys; Hérnandez-Fernaud, Estefanía; Díaz-Cabrera, Dolores; Paravic-Klijn, Tatiana; Burgos-Moreno, Mónica
2015-01-01
OBJECTIVE: To analyse the perception of psychosocial factors and mental workload of nurses who work in intensive care units. It is hypothesised that nurses in these units could perceive psychosocial risks, manifesting in a high mental work load. The psychosocial dimension related to the position's cognitive demands is hypothesised to mostly explain mental work load. METHOD: Quantitative study, with a descriptive, cross-sectional, and comparative design. A total of 91% of the intensive care unit populations of three Chilean hospitals was surveyed, corresponding to 111 nurses. The instruments utilised included (A) a biosociodemographic history questionnaire; (b) the SUSESO-ISTAS 21 questionnaire; and (c) the Mental Work Load Subjective Scale (ESCAM, in Spanish). RESULTS: In total, 64% and 57% of participants perceived high levels of exposure to the psychosocial risks Psychosocial demands and Double shift, respectively. In addition, a medium-high level of overall mental load was observed. Positive and significant correlations between some of the SUSESO-ISTAS 21 and ESCAM dimensions were obtained. Using a regression analysis, it was determined that three dimensions of the psychosocial risk questionnaire helped to explain 38% of the overall mental load. CONCLUSION: Intensive care unit nurses felt that inadequate psychosocial factors and mental work overload existed in several of the tested dimensions. PMID:26039303
Psychosocial factors and mental work load: a reality perceived by nurses in intensive care units.
Ceballos-Vásquez, Paula; Rolo-González, Gladys; Hérnandez-Fernaud, Estefanía; Díaz-Cabrera, Dolores; Paravic-Klijn, Tatiana; Burgos-Moreno, Mónica
2015-01-01
To analyse the perception of psychosocial factors and mental workload of nurses who work in intensive care units. It is hypothesised that nurses in these units could perceive psychosocial risks, manifesting in a high mental work load. The psychosocial dimension related to the position's cognitive demands is hypothesised to mostly explain mental work load. Quantitative study, with a descriptive, cross-sectional, and comparative design. A total of 91% of the intensive care unit populations of three Chilean hospitals was surveyed, corresponding to 111 nurses. The instruments utilised included (A) a biosociodemographic history questionnaire; (b) the SUSESO-ISTAS 21 questionnaire; and (c) the Mental Work Load Subjective Scale (ESCAM, in Spanish). In total, 64% and 57% of participants perceived high levels of exposure to the psychosocial risks Psychosocial demands and Double shift, respectively. In addition, a medium-high level of overall mental load was observed. Positive and significant correlations between some of the SUSESO-ISTAS 21 and ESCAM dimensions were obtained. Using a regression analysis, it was determined that three dimensions of the psychosocial risk questionnaire helped to explain 38% of the overall mental load. Intensive care unit nurses felt that inadequate psychosocial factors and mental work overload existed in several of the tested dimensions.
Patton, Monica E; Kidd, Sarah; Llata, Eloisa; Stenger, Mark; Braxton, Jim; Asbel, Lenore; Bernstein, Kyle; Gratzer, Beau; Jespersen, Megan; Kerani, Roxanne; Mettenbrink, Christie; Mohamed, Mukhtar; Pathela, Preeti; Schumacher, Christina; Stirland, Ali; Stover, Jeff; Tabidze, Irina; Kirkcaldy, Robert D; Weinstock, Hillard
2014-06-01
Gonorrhea (GC) and chlamydia (CT) are the most commonly reported notifiable diseases in the United States. The Centers for Disease Control and Prevention recommends that men who have sex with men (MSM) be screened for urogenital GC/CT, rectal GC/CT, and pharyngeal GC. We describe extragenital GC/CT testing and infections among MSM attending sexually transmitted disease (STD) clinics. The STD Surveillance Network collects patient data from 42 STD clinics. We assessed the proportion of MSM attending these clinics during July 2011-June 2012 who were tested and positive for extragenital GC/CT at their most recent visit or in the preceding 12 months and the number of extragenital infections that would have remained undetected with urethral screening alone. Of 21 994 MSM, 83.9% were tested for urogenital GC, 65.9% for pharyngeal GC, 50.4% for rectal GC, 81.4% for urogenital CT, 31.7% for pharyngeal CT, and 45.9% for rectal CT. Of MSM tested, 11.1% tested positive for urogenital GC, 7.9% for pharyngeal GC, 10.2% for rectal GC, 8.4% for urogenital CT, 2.9% for pharyngeal CT, and 14.1% for rectal CT. More than 70% of extragenital GC infections and 85% of extragenital CT infections were associated with negative urethral tests at the same visit and would not have been detected with urethral screening alone. Extragenital GC/CT was common among MSM attending STD clinics, but many MSM were not tested. Most extragenital infections would not have been identified, and likely would have remained untreated, with urethral screening alone. Efforts are needed to facilitate implementation of extragenital GC/CT screening recommendations for MSM.
Patton, Monica E.; Kidd, Sarah; Llata, Eloisa; Stenger, Mark; Braxton, Jim; Asbel, Lenore; Bernstein, Kyle; Gratzer, Beau; Jespersen, Megan; Kerani, Roxanne; Mettenbrink, Christie; Mohamed, Mukhtar; Pathela, Preeti; Schumacher, Christina; Stirland, Ali; Stover, Jeff; Tabidze, Irina; Kirkcaldy, Robert D.; Weinstock, Hillard
2015-01-01
Background Gonorrhea (GC) and chlamydia (CT) are the most commonly reported notifiable diseases in the United States. The Centers for Disease Control and Prevention recommends that men who have sex with men (MSM) be screened for urogenital GC/CT, rectal GC/CT, and pharyngeal GC. We describe extragenital GC/CT testing and infections among MSM attending sexually transmitted disease (STD) clinics. Methods The STD Surveillance Network collects patient data from 42 STD clinics. We assessed the proportion of MSM attending these clinics during July 2011–June 2012 who were tested and positive for extragenital GC/CT at their most recent visit or in the preceding 12 months and the number of extragenital infections that would have remained undetected with urethral screening alone. Results Of 21 994 MSM, 83.9% were tested for urogenital GC, 65.9% for pharyngeal GC, 50.4% for rectal GC, 81.4% for urogenital CT, 31.7% for pharyngeal CT, and 45.9% for rectal CT. Of MSM tested, 11.1% tested positive for urogenital GC, 7.9% for pharyngeal GC, 10.2% for rectal GC, 8.4% for urogenital CT, 2.9% for pharyngeal CT, and 14.1% for rectal CT. More than 70% of extragenital GC infections and 85% of extragenital CT infections were associated with negative urethral tests at the same visit and would not have been detected with urethral screening alone. Conclusions Extragenital GC/CT was common among MSM attending STD clinics, but many MSM were not tested. Most extragenital infections would not have been identified, and likely would have remained untreated, with urethral screening alone. Efforts are needed to facilitate implementation of extragenital GC/CT screening recommendations for MSM. PMID:24647015
WE-H-BRC-05: Catastrophic Error Metrics for Radiation Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Murphy, S; Molloy, J
Purpose: Intuitive evaluation of complex radiotherapy treatments is impractical, while data transfer anomalies create the potential for catastrophic treatment delivery errors. Contrary to prevailing wisdom, logical scrutiny can be applied to patient-specific machine settings. Such tests can be automated, applied at the point of treatment delivery and can be dissociated from prior states of the treatment plan, potentially revealing errors introduced early in the process. Methods: Analytical metrics were formulated for conventional and intensity modulated RT (IMRT) treatments. These were designed to assess consistency between monitor unit settings, wedge values, prescription dose and leaf positioning (IMRT). Institutional metric averages formore » 218 clinical plans were stratified over multiple anatomical sites. Treatment delivery errors were simulated using a commercial treatment planning system and metric behavior assessed via receiver-operator-characteristic (ROC) analysis. A positive result was returned if the erred plan metric value exceeded a given number of standard deviations, e.g. 2. The finding was declared true positive if the dosimetric impact exceeded 25%. ROC curves were generated over a range of metric standard deviations. Results: Data for the conventional treatment metric indicated standard deviations of 3%, 12%, 11%, 8%, and 5 % for brain, pelvis, abdomen, lung and breast sites, respectively. Optimum error declaration thresholds yielded true positive rates (TPR) between 0.7 and 1, and false positive rates (FPR) between 0 and 0.2. Two proposed IMRT metrics possessed standard deviations of 23% and 37%. The superior metric returned TPR and FPR of 0.7 and 0.2, respectively, when both leaf position and MUs were modelled. Isolation to only leaf position errors yielded TPR and FPR values of 0.9 and 0.1. Conclusion: Logical tests can reveal treatment delivery errors and prevent large, catastrophic errors. Analytical metrics are able to identify errors in monitor units, wedging and leaf positions with favorable sensitivity and specificity. In part by Varian.« less
NASA Technical Reports Server (NTRS)
Kaufmann, David N.; Ncnally, B. David
1995-01-01
Test flights were conducted to evaluate the capability of Differential Global Positioning System (DGPS) to provide the accuracy and integrity required for International Civil Aviation Organization (ICAO) Category (CAT) 3 precision approach and landings. These test flights were part of a Federal Aviation Administration (FAA) program to evaluate the technical feasibility of using DGPS based technology for CAT 3 precision approach and landing applications. A United Airlines Boeing 737-300 (N304UA) was equipped with DGPS receiving equipment and additional computing capability provided by Stanford University. The test flights were conducted at NASA Ames Research Center's Crows Landing Flight Facility, Crows Landing, California. The flight test evaluation was based on completing 100 approaches and autolandings; 90 touch and go, and 10 terminating with a full stop. Two types of accuracy requirements were evaluated: 1) Total system error, based on the Required Navigation Performance (RNP), and 2) Navigation sensor error, based on ICAO requirements for the Microwave Landing System (MLS). All of the approaches and autolandings were evaluated against ground truth reference data provided by a laser tracker. Analysis of these approaches and autolandings shows that the Stanford University/United Airlines system met the requirements for a successful approach and autolanding 98 out of 100 approaches and autolandings, based on the total system error requirements as specified in the FAA CAT 3 Level 2 Flight Test Plan.
Star Excursion Balance Test performance and application in elite junior rugby union players.
Coughlan, Garrett F; Delahunt, Eamonn; O'Sullivan, Eoghan; Fullam, Karl; Green, Brian S; Caulfield, Brian M
2014-11-01
To evaluate performance on selected reach directions of the Start Excursion Balance Test (SEBT) in an elite underage rugby union population, and determine if differences exist between the forward and back position units. This information may have implications for the application of this test in player injury prevention and management. Descriptive study. Gymnasium at an elite junior rugby union screening camp. 102 healthy male elite rugby union players (age = 17.9 ± 1.1 years, height = 1.83 ± 0.07 m, body mass = 90.5 ± 11.3 kg). Participants were assessed on the Anterior (A), Posterior-medial (PM), and Posterior-lateral (PL) reach directions of the SEBT. Normative data for SEBT performance in the A, PM and PL reach directions were established for an elite junior rugby union population. No significant differences in dynamic postural stability were observed between the forward and back position units. This study provides normative SEBT data on an elite junior rugby union population, which enables clinicians to compare player dynamic postural stability and has implications for use in the prevention and management of player injuries. Copyright © 2013 Elsevier Ltd. All rights reserved.
Bohaychuk, Valerie M.; Checkley, Sylvia L.; Gensler, Gary E.; Barrios, Pablo Romero
2009-01-01
Studies to determine baseline levels of microbial contaminants and foodborne bacterial pathogens are needed to evaluate the effectiveness of Hazard Analysis Critical Control Point (HACCP) programs, Good Manufacturing/Production Practices, and various interventions. In 2004 and 2005 poultry carcass rinses from provincially inspected abattoirs in Alberta, Canada, were tested to determine the levels of aerobic plate count bacteria, coliform bacteria, and generic Escherichia coli, the prevalence and levels of Campylobacter spp., and the prevalence of Salmonella spp. and Shiga toxin-producing E. coli (STEC). Samples were collected from 3 high volume and 62 low volume abbatoirs. All samples (1296) were positive for aerobic plate count bacteria, with 98.8% of samples having counts of 100 000 or less colony forming units (CFU)/cm2. Coliform bacteria were isolated from 99.7% of the 1296 carcasses and were recovered at levels of ≤ 1000 CFU/cm2 for 98.3% of the samples. Generic E. coli were recovered from 99.1% of the 1296 carcasses at levels of ≤ 1000 CFU/cm2 for 98.6% of the samples. Seventy five percent of 1234 samples that were tested for Campylobacter were positive; 37.5% of 1295 samples that were tested for Salmonella were positive; and only 2 of 1296 samples tested for STEC were positive (0.15%). PMID:19412397
Kamenova, Kalina; Reshef, Amir; Caulfield, Timothy
2014-07-01
This study investigates the portrayal of Angelina Jolie's preventive bilateral mastectomy in the news media. Content analysis of print news was conducted to identify major frames used in press coverage, the overall tone of discussions, how journalists report broader questions about BRCA1/2 testing and hereditary breast/ovarian cancer, and whether they raise concerns about the impact of celebrities on patients' choices and public opinion. The Factiva database was used to collect publications on Jolie's preventive mastectomy in elite newspapers in Canada, the United States, and the United Kingdom. The data set consisted of 103 newspaper articles published in the first month of media coverage. The results show that although the press discussed key issues surrounding predictive genetic testing and preventive options for women at high risk of hereditary breast/ovarian cancer, important medical information about the rarity of Jolie's condition was not communicated to the public. The results highlight the media's overwhelmingly positive slant toward Jolie's mastectomy, while overlooking the relative rarity of her situation, the challenges of "celebrity medicine," and how celebrities influence people's medical decisions. Future research is required to investigate whether the media hype has influenced demand and use of BRCA1/2 testing and preventive mastectomies.
Design and testing of the reactor-internal hydraulic control rod drive for the nuclear heating plant
DOE Office of Scientific and Technical Information (OSTI.GOV)
Batheja, P.; Meier, W.J.; Rau, P.J.
A hydraulically driven control rod is being developed at Kraftwerk Union for integration in the primary system of a small nuclear district heating reactor. An elaborate test program, under way for --3 yr, was initiated with a plexiglass rig to understand the basic principles. A design specification list was prepared, taking reactor boundary conditions and relevant German rules and regulations into account. Subsequently, an atmospheric loop for testing of components at 20 to 90/sup 0/C was erected. The objectives involved optimization of individual components such as a piston/cylinder drive unit, electromagnetic valves, and an ultrasonic position indication system as wellmore » as verification of computer codes. Based on the results obtained, full-scale components were designed and fabricated for a prototype test rig, which is currently in operation. Thus far, all atmospheric tests in this rig have been completed. Investigations under reactor temperature and pressure, followed by endurance tests, are under way. All tests to date have shown a reliable functioning of the hydraulic drive, including a novel ultrasonic position indication system.« less
Cardoso, Débora Morais; Gilio, Alfredo Elias; Hsin, Shieh Huei; Machado, Beatriz Marcondes; de Paulis, Milena; Lotufo, João Paulo B; Martinez, Marina Baquerizo; Grisi, Sandra Josefina E
2013-01-01
To evaluate the impact of the routine use of rapid antigen detection test in the diagnosis and treatment of acute pharyngotonsillitis in children. This is a prospective and observational study, with a protocol compliance design established at the Emergency Unit of the University Hospital of Universidade de São Paulo for the care of children and adolescents diagnosed with acute pharyngitis. 650 children and adolescents were enrolled. Based on clinical findings, antibiotics would be prescribed for 389 patients (59.8%); using the rapid antigen detection test, they were prescribed for 286 patients (44.0%). Among the 261 children who would not have received antibiotics based on the clinical evaluation, 111 (42.5%) had positive rapid antigen detection test. The diagnosis based only on clinical evaluation showed 61.1% sensitivity, 47.7% specificity, 44.9% positive predictive value, and 57.5% negative predictive value. The clinical diagnosis of streptococcal pharyngotonsillitis had low sensitivity and specificity. The routine use of rapid antigen detection test led to the reduction of antibiotic use and the identification of a risk group for complications of streptococcal infection, since 42.5% positive rapid antigen detection test patients would not have received antibiotics based only on clinical diagnosis.
Test and Validation of the Mars Science Laboratory Robotic Arm
NASA Technical Reports Server (NTRS)
Robinson, M.; Collins, C.; Leger, P.; Kim, W.; Carsten, J.; Tompkins, V.; Trebi-Ollennu, A.; Florow, B.
2013-01-01
The Mars Science Laboratory Robotic Arm (RA) is a key component for achieving the primary scientific goals of the mission. The RA supports sample acquisition by precisely positioning a scoop above loose regolith or accurately preloading a percussive drill on Martian rocks or rover-mounted organic check materials. It assists sample processing by orienting a sample processing unit called CHIMRA through a series of gravity-relative orientations and sample delivery by positioning the sample portion door above an instrument inlet or the observation tray. In addition the RA facilitates contact science by accurately positioning the dust removal tool, Alpha Particle X-Ray Spectrometer (APXS) and the Mars Hand Lens Imager (MAHLI) relative to surface targets. In order to fulfill these seemingly disparate science objectives the RA must satisfy a variety of accuracy and performance requirements. This paper describes the necessary arm requirement specification and the test campaign to demonstrate these requirements were satisfied.
NASA Technical Reports Server (NTRS)
Oliver, B. M.; Gower, J. F. R.
1977-01-01
A data acquisition system using a Litton LTN-51 inertial navigation unit (INU) was tested and used for aircraft track recovery and for location and tracking from the air of targets at sea. The characteristic position drift of the INU is compensated for by sighting landmarks of accurately known position at discrete time intervals using a visual sighting system in the transparent nose of the Beechcraft 18 aircraft used. For an aircraft altitude of about 300 m, theoretical and experimental tests indicate that calculated aircraft and/or target positions obtained from the interpolated INU drift curve will be accurate to within 10 m for landmarks spaced approximately every 15 minutes in time. For applications in coastal oceanography, such as surface current mapping by tracking artificial targets, the system allows a broad area to be covered without use of high altitude photography and its attendant needs for large targets and clear weather.
Design and performance of a high resolution, low latency stripline beam position monitor system
NASA Astrophysics Data System (ADS)
Apsimon, R. J.; Bett, D. R.; Blaskovic Kraljevic, N.; Burrows, P. N.; Christian, G. B.; Clarke, C. I.; Constance, B. D.; Dabiri Khah, H.; Davis, M. R.; Perry, C.; Resta López, J.; Swinson, C. J.
2015-03-01
A high-resolution, low-latency beam position monitor (BPM) system has been developed for use in particle accelerators and beam lines that operate with trains of particle bunches with bunch separations as low as several tens of nanoseconds, such as future linear electron-positron colliders and free-electron lasers. The system was tested with electron beams in the extraction line of the Accelerator Test Facility at the High Energy Accelerator Research Organization (KEK) in Japan. It consists of three stripline BPMs instrumented with analogue signal-processing electronics and a custom digitizer for logging the data. The design of the analogue processor units is presented in detail, along with measurements of the system performance. The processor latency is 15.6 ±0.1 ns . A single-pass beam position resolution of 291 ±10 nm has been achieved, using a beam with a bunch charge of approximately 1 nC.
NASA Astrophysics Data System (ADS)
Tofel-Grehl, Colby; Fields, Deborah; Searle, Kristin; Maahs-Fladung, Cathy; Feldon, David; Gu, Grace; Sun, Chongning
2017-08-01
Most interventions with "maker" technologies take place outside of school or out of core area classrooms. However, intervening in schools holds potential for reaching much larger numbers of students and the opportunity to shift instructional dynamics in classrooms. This paper shares one such intervention where electronic textiles (sewable circuits) were introduced into eighth grade science classes with the intent of exploring possible gains in student learning and motivation, particularly for underrepresented minorities. Using a quasi-experimental design, four classes engaged in a traditional circuitry unit while the other four classes undertook a new e-textile unit. Overall, students in both groups demonstrated significant learning gains on standard test items without significant differences between conditions. Significant differences appeared between groups' attitudes toward science after the units in ways that show increasing interest in science by students in the e-textile unit. In particular, they reported positive identity shifts pertaining to their perceptions of the beliefs of their friends, family, and teacher. Findings and prior research suggest that student-created e-textile designs provide opportunities for connections outside of the classroom with friends and family and may shift students' perceptions of their teacher's beliefs about them more positively.
Ramirez-Arcos, Sandra; DiFranco, Caesar; McIntyre, Terri; Goldman, Mindy
2017-09-01
Canadian Blood Services screens 100% of platelet concentrates (PCs) for bacterial contamination with the BacT/ALERT system. Quality-control sterility testing of 1% (≥10 units) of outdated PCs is performed monthly. Data from routine screening, quality-control testing, and septic reactions obtained from 2010 to 2016 are presented herein. In total, 601,988 buffy coat PC pools and 186,737 apheresis PCs were routinely screened with aerobic cultures over 6 years. Outdate quality-control testing of 8535 buffy coat and 8498 apheresis PCs was performed using aerobic and anaerobic cultures during the same period. Results were classified as "true-positives" when the same bacterium was isolated in initial and confirmatory cultures or "false-negatives" when bacteria were missed in early screening and were captured during quality-control sterility testing or through investigation of sepsis cases. During routine screening, the true-positive rates between buffy coat (0.94 per 10,000) and apheresis (0.96 per 10,000) PCs were similar (p = 0.9473). Seventy-five bacteria isolated during PC screening included Gram-positive and Gram-negative organisms. Six false-negative septic reactions were reported that implicated coagulase-negative staphylococci (n = 3) and Staphylococcus aureus (n = 3) for approximate rates of 1 per 100,000 transfusion reactions and 1 per 500,000 fatalities. During quality-control testing, the false-negative rates between buffy coat (8 per 10,000) and apheresis (9 per 10,000) PCs were similar (p = 0.7897). All 15 quality-control isolates were Gram-positive bacteria. The current bacterial screening protocol is efficacious for identifying Gram-negative bacteria. However, the high proportion of Gram-positive organisms detected on outdate quality-control testing and septic transfusion events demonstrates a residual safety risk that merits further intervention. © 2017 AABB.
Development status of the PDC-1 Parabolic Dish Concentrator
NASA Technical Reports Server (NTRS)
Thostesen, T.; Soczak, I. F.; Pons, R. L.
1982-01-01
The status of development of the 12 m diameter parabolic dish concentrator which is planned for use with the Small Community Solar Thermal Power System. The PDC-1 unit features the use of plastic reflector film bonded to structural plastic gores supported by front-bracing steel ribs. An elevation-over-azimuth mount arrangement is employed, with a conventional wheel-and-track arrangement; outboard trunnions permit the dish to be stored in the face down position, with the added advantage of easy access to the power conversion assembly. The control system is comprised of a central computer (LSI 1123), a manual control panel, a concentrator control unit, two motor controllers, a Sun sensor, and two angular position resolvers. The system is designed for the simultaneous control of several concentrators. The optical testing of reflective panels is described.
Economic opportunity in Mexico and return migration from the United States.
Lindstrom, D P
1996-08-01
I analyze the influence of the economic characteristics of origin area on trip duration for Mexican migrants in the United States. I argue that migrants from economically dynamic areas in Mexico with favorable opportunities for employment and small capital investment have a larger incentive to stay in the United States longer and to withstand the psychic costs of separation from family and friends than do migrants from economically stagnant areas in Mexico, where the productive uses of savings are severely limited. In line with this argument we should expect investment opportunities in migrants' origin areas to be associated positively with migrants' trip duration in the United States. To test this hypothesis I use individual- and household-level data on U.S. migration experience collected in 13 Mexican communities. Evidence from parametric hazards models supports the idea that economic characteristics of origin areas influence the motivations and strategies of Mexican migrants in the United States.
Mullen, Keena AE; Beasley, Erin; Rizzo, Julio Q; Washburn, Steven P; Baynes, Ronald E; Mason, Sharon E
2017-01-01
Mastitis is a costly disease for dairy farmers. Some dairy farmers use herbal products, or phytoceuticals, to treat mastitis. Phytoceuticals have not been approved for this use by the United States Food and Drug Administration, and have not been tested to determine how they impact antibiotic residue detection testing. The current study tested the potential for phytoceuticals to cause positive results on two milk antibiotic residue screening tests, the Delvotest P and Charm SL Beta-lactam test, or to interfere with the detection of antibiotics by these tests. The three phytoceuticals tested were labelled for intramammary, topical or intravulvar administration. Testing was performed in vitro using the products diluted in milk obtained from healthy organic dairy cows. Phytoceuticals were tested at concentrations ranging from 1.5 per cent to 100 per cent. Concentration levels were replicated at least twice on each milk antibiotic residue screening test. The Delvotest P is based on detection of bacterial inhibitors and no positive results were obtained for any product at concentrations less than 50 per cent. The Charm SL Beta-lactam test uses a receptor for the detection of beta-lactam antibiotics and no concentration of phytoceuticals caused an interference with these tests. Based on dilution of the products in bovine milk at physiologically achievable levels, phytoceutical products tested at levels expected after treatment do not cause positive test results for the Delvotest P nor do they interfere with the Charm SL Beta-lactam test in detection of various antibiotics. PMID:28890791
Infectious agent screening in canine blood donors in the United Kingdom.
Crawford, K; Walton, J; Lewis, D; Tasker, S; Warman, S M
2013-08-01
Transfusion of blood products is an important component of veterinary emergency medicine. Donors must be carefully selected to minimise risk of transmission of blood-borne infectious agents. This study was devised to assess the prevalence of such agents in healthy, non-travelled UK dogs screened as prospective donors. Ethylenediaminetetraacetic acid blood samples from dogs donating blood between August 2007 and January 2012 were screened by polymerase chain reaction for haemotropic mycoplasmas, Bartonella, Babesia, Leishmania, Ehrlichia and Anaplasma spp. Dogs with positive or inconclusive results underwent repeat polymerase chain reaction testing. Four of 262 dogs had positive or inconclusive results at initial screening. Repeat polymerase chain reaction testing in each dog was negative, and none of the dogs developed clinical signs of disease. The positive results on initial screening may have represented false positives from sample contamination or amplification of non-target DNA. It is also possible that dogs were infected at initial sampling but successfully cleared infection before repeat testing. The low number of positive results obtained suggests that prevalence of these agents in a population of healthy UK dogs is low and that use of blood products is unlikely to represent a significant risk of transmission of these diseases. © 2013 British Small Animal Veterinary Association.
Sedikides, Constantine; Gaertner, Lowell; Toguchi, Yoshiyasu
2003-01-01
The culture movement challenged the universality of the self-enhancement motive by proposing that the motive is pervasive in individualistic cultures (the West) but absent in collectivistic cultures (the East). The present research posited that Westerners and Easterners use different tactics to achieve the same goal: positive self-regard. Study 1 tested participants from differing cultural backgrounds (the United States vs. Japan), and Study 2 tested participants of differing self-construals (independent vs. interdependent). Americans and independents self-enhanced on individualistic attributes, whereas Japanese and interdependents self-enhanced on collectivistic attributes. Independents regarded individualistic attributes, whereas interdependents regarded collectivistic attributes, as personally important. Attribute importance mediated self-enhancement. Regardless of cultural background or self-construal, people self-enhance on personally important dimensions. Self-enhancement is a universal human motive.
2007-10-01
determine how MNA is impacting the rate of CAH destruction, and 3) evaluate the success of the pilot testing . The recommended locations, frequencies...Wells N ...... Trichloroethylene (ICE) c~•’-: lfN Concentration In ppb A 1.,(.,.111*-hl D .... TAFB Boundary - Sppb OtWI-Ht-11!1 ... NO = Not...Additionally, ACM tested positive from glue in the flooring of the units (U.S. Air Force, 2003; U.S. Air Force, 2007b). Tinker AFB maintains a computerized
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-12
... DEPARTMENT OF HOMELAND SECURITY Coast Guard [Docket No. USCG-2011-1106] Dynamic Positioning... ``Mobile Offshore Drilling Unit Dynamic Positioning Guidance''. The notice recommended owners and operators of Mobile Offshore Drilling Units (MODUs) follow Marine Technology Society (MTS) Dynamic Positioning...
40 CFR 63.8105 - What definitions apply to this subpart?
Code of Federal Regulations, 2010 CFR
2010-07-01
... component is synthesized by chemical reaction or separation activity and then transferred to another vessel... using an engineering assessment as discussed in § 63.1257(d)(2)(ii), test data using Method 18 of 40 CFR... individual unit of equipment used for the purpose of recovering chemicals for fuel value (i.e., net positive...
USDA-ARS?s Scientific Manuscript database
Prezygotic isolation due to habitat choice is important to many models of speciation-with-gene-flow. Habitat choice is usually thought to occur through positive preferences of organisms for particular environments. However, avoidance of non-natal environments may also play a role in choice and have ...
ERIC Educational Resources Information Center
Koyama, Jill P.; Cofield, Candace
2013-01-01
A discourse placing schools in the service of the economy has become ubiquitous in the United States (US), and current educational policies, including No Child Left Behind (NCLB) and movements, such as the Common Core Learning Standards, have been positioned as necessary in an account of global competitiveness. In this hegemonic script,…
Kaehler, Dawn; Cebelinski, Elizabeth A.; Nefzger, Brian; Hall, Aron J.; Smith, Kirk E.
2013-01-01
Norovirus is the leading cause of foodborne disease in the United States. During October 2011–January 2013, we conducted surveillance for norovirus infection in Minnesota among callers to a complaint-based foodborne illness hotline who reported diarrhea or vomiting. Of 241 complainants tested, 127 (52.7%) were positive for norovirus. PMID:23876924
USDA-ARS?s Scientific Manuscript database
The United States Department of Agriculture Food Safety and Inspection Service (FSIS) recently adapted the use of the Charm Kidney Inhibition Swab (KIS) test for screening antibiotics on-site, along with a LC-MS/MS method for confirmation of KIS-positive samples. A study with 126 heavy sows (227.0 ...
Oyagüe, Raquel Castillo; Sánchez-Turrión, Andrés; López-Lozano, José Francisco; Montero, Javier; Albaladejo, Alberto; Suárez-García, María Jesús
2012-07-01
This study evaluated the vertical discrepancy of implant-fixed 3-unit structures. Frameworks were constructed with laser-sintered Co-Cr, and vacuum-cast Co-Cr, Ni-Cr-Ti, and Pd-Au. Samples of each alloy group were randomly luted in standard fashion using resin-modified glass-ionomer, self-adhesive, and acrylic/urethane-based cements (n = 12 each). Discrepancies were SEM analyzed. Three-way ANOVA and Student-Newman-Keuls tests were run (P < 0.05). Laser-sintered structures achieved the best fit per cement tested. Within each alloy group, resin-modified glass-ionomer and acrylic/urethane-based cements produced comparably lower discrepancies than the self-adhesive agent. The abutment position did not yield significant differences. All misfit values could be considered clinically acceptable.
Serological markers for hepatitis types A and B among U.S. Arym soldiers, Germany.
James, J J; Smith, L
1979-01-01
Viral hepatitis rates among U.S. Army soldiers in Europe have been found to be two to three times higher than corresponding rates for soldiers stationed in the U.S. Sera from 89 per cent of a representative Army unit with 865 members and a known hepatitis problem were tested for HBsAg, anti-HBs, anti-HBc, and anti-HA. The prevalence of HB markers was 20 per cent, and hepatitis A antibody was present in 25 per cent. A six-month follow-up, conducted on 260 individuals initially negative for all four tests, revealed that 11 of these were now HB seropositive, whereas none had seroconverted to anti-HA positive. The HB virus was the principal agent responsible for hepatitis in the unit surveyed. PMID:228562
Assessment of recent HIV testing among older adults in the United States.
Guo, Yuqi; Sims, Omar T
2017-10-01
Older adults are the fastest growing segment of people living with HIV, and unfortunately many are unaware of their HIV status. Many providers are reluctant to ask older adults about their sexual histories, evaluate their risk factors, and test for HIV, and older adults have low perception of HIV risk. Using data from the 2013 to 2014 National Health and Nutrition Examination Survey, this study assessed the prevalence of recent HIV testing among older adults in the United States (n = 1,056) and identified predictors and barriers to recent HIV testing. The prevalence of recent HIV testing was 28%. Recent HIV testing was associated positively with male gender, education level, having public insurance, having same sex sexual behavior, African, and Hispanic ethnicity, whereas age, income-to-poverty ratio, and Asian ethnicity were associated negatively with recent HIV testing. Public health social workers are advised that targeted HIV testing for Asian, economically disadvantaged, female older adults is needed to increase HIV awareness and detection and to decrease late diagnosis of HIV. Provided public insurance was identified as a predictor of recent HIV testing, facilitating economically disadvantaged older adults' eligibility for public insurance that will likely improve access to HIV testing services and increase HIV testing rates.
Margolis, Andrew D; Joseph, Heather; Belcher, Lisa; Hirshfield, Sabina; Chiasson, Mary Ann
2012-01-01
HIV testing was assessed online among men accessing a sexual networking website for men who have sex with men. Most of the 8,040 participants reported HIV testing (58.2% ≤ 1 year; 33.1% > 1 year) and 17.1% were HIV-positive. Overall, 8.6% of men including 24% of those 18-24 years of age had never been tested. Among never testers, 25% did not know where to get tested. Predictors of never being tested included younger age (18-24), bisexual or heterosexual orientation, living outside of large metropolitan areas, and not having a healthcare provider. Increasing access to and knowledge of HIV testing sites is needed.
Rapid characterization of seismic sources in Chile: Contribution of the GNSS component
NASA Astrophysics Data System (ADS)
Barrientos, S. E.; Riquelme, S.; Baez, J. C., Sr.
2017-12-01
The recently created National Seismological Center (CSN) of the University of Chile was tasked to upgrade the countrýs seismic network in 2013. The upgrade included new 65 collocated accelerometer and broadband instruments together with 130 GNSS devices designed to transmit their data in real time. Forty units of the GNSS devices include the RTX option, a real time 1-Hz positioning capability at 4-cm error level. The observation system is complemented with 297 additional stand-alone strong motion instruments mainly located in basins for seismic engineering purposes. Broadband data can be accessed in real time from IRIS Data Management Service under networks C and C1. Strong motion event data can be retrieved through the CSN database (evtdb.csn.uchile.cl). A server is being established to handle GNSS data requests through an NTRIP Caster. Completion of the connectivity of the GNSS remote units to the main acquisition servers is expected to take place within several months. In addition to the 40 units providing real time positioning through the RTX option, Precise Point Positioning (PPP) algorithms are being tested on the CSN main servers to enable real time estimates every second for all GNSS remote devices. Because of the high earthquake productivity rate in Chile, the RTX system capabilities have been positively tested in two cases already, demonstrating their excellent performance: i) the main aftershock (M7.6) of the April 1, 2014, northern Chile event and ii) the April 24, 2017, (M6.9) event in central Chile. The former produced coastal horizontal static displacements of the order of 30 cm while the latter of the order of 5 cm. In addition to rapid earthquake characterization through static deformation, W-phase displacement waveform inversions are included in the fast analysis providing excellent results. These new applications and methodologies have profoundly impacted the rapid evaluation of the tsunamigenic potential of large earthquakes in the near field.
Cross-Cultural Validity of the Ruminative Responses Scale in Argentina and the United States.
Arana, Fernán G; Rice, Kenneth G
2017-09-01
Although frequently used in the United States, the Ruminative Response Scale (RRS) has not been extensively studied in cross-cultural samples. The present study evaluated the factor structure of Treynor et al.'s 10-item version of the RRS in samples from Argentina ( N = 308) and the United States ( N = 371). In addition to testing measurement invariance between the countries, we evaluated whether the maladaptive implications of rumination were weaker for the Argentinians than for the U.S. group. Self-critical perfectionism was the criterion in those tests. Partial scalar invariance supported an 8-item version of the RRS. There were no differences in factor means or factor correlations in RRS dimensions between countries. Brooding and Reflection were positively correlated with self-critical perfectionism in both countries, with no significant differences in the sizes of these relations between the two samples. Results are discussed in terms of psychometric and cross-cultural implications for rumination.
Borrelia miyamotoi sensu lato seroreactivity and seroprevalence in the northeastern United States.
Krause, Peter J; Narasimhan, Sukanya; Wormser, Gary P; Barbour, Alan G; Platonov, Alexander E; Brancato, Janna; Lepore, Timothy; Dardick, Kenneth; Mamula, Mark; Rollend, Lindsay; Steeves, Tanner K; Diuk-Wasser, Maria; Usmani-Brown, Sahar; Williamson, Phillip; Sarksyan, Denis S; Fikrig, Erol; Fish, Durland
2014-07-01
Borrelia miyamotoi sensu lato, a relapsing fever Borrelia sp., is transmitted by the same ticks that transmit B. burgdorferi (the Lyme disease pathogen) and occurs in all Lyme disease-endemic areas of the United States. To determine the seroprevalence of IgG against B. miyamotoi sensu lato in the northeastern United States and assess whether serum from B. miyamotoi sensu lato-infected persons is reactive to B. burgdorferi antigens, we tested archived serum samples from area residents during 1991-2012. Of 639 samples from healthy persons, 25 were positive for B. miyamotoi sensu lato and 60 for B. burgdorferi. Samples from ≈10% of B. miyamotoi sensu lato-seropositive persons without a recent history of Lyme disease were seropositive for B. burgdorferi. Our results suggest that human B. miyamotoi sensu lato infection may be common in southern New England and that B. burgdorferi antibody testing is not an effective surrogate for detecting B. miyamotoi sensu lato infection.
MEGARA: large pupil element tests and performance
NASA Astrophysics Data System (ADS)
Martínez-Delgado, I.; Sánchez-Blanco, E.; Pérez-Calpena, A.; García-Vargas, M. L.; Maldonado, X. M.; Gil de Paz, A.; Carrasco, E.; Gallego, J.; Iglesias-Páramo, J.; Sánchez-Moreno, F. M.
2016-07-01
MEGARA is a third generation spectrograph for the Spanish 10.4m telescope (GTC) providing two observing modes: a large central Integral Field Unit (IFU), called the Large Compact Bundle (LCB), covering a FOV of 12.5 × 11.3 arcsec2, and a Multi-Object Spectrograph (MOS) with a FOV of 3.5 × 3.5 arcmin2. MEGARA will observe the whole visible range from 3650A to 10000A allowing different spectral resolutions (low, medium and high) with R = 6000, 11000 and 18000 respectively. The dispersive elements are placed at the spectrograph pupil position in the path of the collimated beam and they are composed of a set of volume phase hologram gratings (VPHs) sandwiched between two flat windows and coupled in addition to two prisms in the case of the medium- and high-resolution units. We will describe the tests and setups developed to check the requirements of all units, as well as the obtained performance at laboratory
THE ANTIBACTERIAL PROPERTIES OF SULFUR
Weld, Julia T.; Gunther, Anne
1947-01-01
1. Saturated solutions of sulfur in alcohol (alcohol-sulfur) when diluted with broth are inhibitory to the growth of various Gram-positive bacteria and to C. hominis. By an arbitrary method of unitage with S. aureus as the test organism, our alcohol-sulfur contains 1,600 to 2,000 units per cc. and one unit contains between 0.24 and 0.34 gamma sulfur. The activity of a preparation is in general directly proportional to its sulfur content. 2. Solutions of sulfur in carbowax (carbowax-sulfur) when diluted with broth are likewise inhibitory to the growth of various Gram-positive bacteria and to C. hominis. When S. aureus is used as test organism, 1 unit contains between 0.1 and 0.2 gamma sulfur. The activity of these preparations is also in general directly proportional to their sulfur content. 3. Carbowax-sulfur when incorporated in agar in 1–500 to 1–2,000 dilution inhibits the growth of various Gram-positive aerobic and anaerobic bacteria, C. hominis, and certain dermatophytes. 4. Our experiments appear to show that both alcohol-sulfur and carbowax-sulfur owe their inhibitory properties to the sulfur particles that are dispersed throughout the medium when these sulfur preparations are diluted with broth. The inhibitory effect of these particles may or may not be due to a combination of the sulfur particles with substances in the medium in which they are suspended. 5. Evidence suggests that the activity of both alcohol-sulfur and carbowax-sulfur is due to sulfur in the same form. The inhibitory effect is characterized by prolonged bacteriostasis with similar activity over a wide range of dilutions. There is no evidence of true bactericidal action even with the highest concentrations used. PMID:19871634
Rhomberg, Paul R.; Huband, Michael D.; Farrell, David J.
2016-01-01
Delafloxacin, an investigational anionic fluoroquinolone, is active against a broad range of Gram-positive and Gram-negative bacteria. In this study, 200 Streptococcus pneumoniae (plus 30 levofloxacin-resistant isolates), 200 Haemophilus influenzae, and 100 Moraxella catarrhalis isolates selected primarily from the United States (2014) were tested against delafloxacin and comparator agents. Delafloxacin was the most potent agent tested. MIC50 and MIC90 values against all S. pneumoniae isolates were 0.008 and 0.015 μg/ml. Delafloxacin susceptibility was not affected by β-lactamase status against H. influenzae and M. catarrhalis. PMID:27458220
Engineers test STS-37 CETA electrical hand pedal cart in JSC MAIL Bldg 9A
NASA Technical Reports Server (NTRS)
1990-01-01
McDonnell Douglas engineers Noland Talley (left) and Gary Peters (center) and ILC-Dover engineer Richard Richard Smallcombe prepare test setup for the evaluation of the crew and equipment translation aid (CETA) electrical hand pedal cart in JSC's Mockup and Integration Laboratory (MAIL) Bldg 9A. Peters, wearing extravehicular mobility unit (EMU) boots and positioned in portable foot restraint (PFR), is suspended above CETA cart and track via harness to simulate weightlessness. CETA will be tested in orbit in the payload bay of Atlantis, Orbiter Vehicle (OV) 104, during STS-37.
NASA Technical Reports Server (NTRS)
Martinez, Andres; Benavides, Jose Victor; Ormsby, Steve L.; GuarnerosLuna, Ali
2014-01-01
Synchronized Position Hold, Engage, Reorient, Experimental Satellites (SPHERES) are bowling-ball sized satellites that provide a test bed for development and research into multi-body formation flying, multi-spacecraft control algorithms, and free-flying physical and material science investigations. Up to three self-contained free-flying satellites can fly within the cabin of the International Space Station (ISS), performing flight formations, testing of control algorithms or as a platform for investigations requiring this unique free-flying test environment. Each satellite is a self-contained unit with power, propulsion, computers, navigation equipment, and provides physical and electrical connections (via standardized expansion ports) for Principal Investigator (PI) provided hardware and sensors.
de Santiago, J; Santos-Yglesias, J; Girón, J; Jiménez, A; Errando, C L
2010-11-01
To compare the percentage of patients who were able to bypass the postoperative intensive care recovery unit after selective spinal anesthesia with lidocaine-fentanyl versus levobupivacaine-fentanyl for anorectal surgery in jackknife position. Randomized double-blind clinical trial comparing 2 groups of 30 patients classified ASA 1-2. One group received 18 mg of 0.6% lidocaine plus 10 microg of fentanyl while the other group received 3 mg of 0.1% levobupivacaine plus 10 microg of fentanyl. Intraoperative variables were time of start of surgery, maximum extension of sensory blockade, requirement for rescue analgesics, and hemodynamic events. The level of sensory blockade was recorded at 5, 10, and 15 minutes after the start of surgery and at the end of the procedure. The degrees of postoperative motor blockade and proprioception were recorded, as were the results of the Romberg test and whether or not the patient was able to bypass the postoperative recovery unit. Also noted were times of start of ambulation and discharge, complications, and postoperative satisfaction. Intraoperative variables did not differ significantly between groups, and all patients in both groups bypassed the postoperative recovery unit. Times until walking and discharge home, complications, and overall satisfaction after surgery were similar in the 2 groups. Both spinal anesthetic solutions provide effective, selective anesthesia and are associated with similar rates of recovery care unit bypass after anorectal surgery in jackknife position.
West, Devin M.; McCauley, Lindsay M.; Sorensen, Jeffrey S.; Jephson, Al R.
2016-01-01
The pneumocococcal urine antigen test increases specific microbiological diagnosis over conventional culture methods in pneumonia patients. Data are limited regarding its yield and effect on antibiotic prescribing among patients with community-onset pneumonia in clinical practice. We performed a secondary analysis of 2837 emergency department patients admitted to seven Utah hospitals over 2 years with international diagnostic codes version 9 codes and radiographic evidence of pneumonia. Mean age was 64.2 years, 47.2% were male and all-cause 30-day mortality was 9.6%. Urinary antigen testing was performed in 1110 (39%) patients yielding 134 (12%) positives. Intensive care unit patients were more likely to undergo testing, and have a positive result (15% versus 8.8% for ward patients; p<0.01). Patients with risk factors for healthcare-associated pneumonia had fewer urinary antigen tests performed, but 8.4% were positive. Physicians changed to targeted antibiotic therapy in 20 (15%) patients, de-escalated antibiotic therapy in 76 patients (57%). In 38 (28%) patients, antibiotics were not changed. Only one patient changed to targeted therapy suffered clinical relapse. Length of stay and mortality were lower in patients receiving targeted therapy. Pneumococcal urinary antigen testing is an inexpensive, noninvasive test that favourably influenced antibiotic prescribing in a “real world”, multi-hospital observational study. PMID:28053969
The efficacy of hair and urine toxicology screening on the detection of child abuse by burning.
Hayek, Shady N; Wibbenmeyer, Lucy A; Kealey, Lyn Dee H; Williams, Ingrid M; Oral, Resmiye; Onwuameze, Obiora; Light, Timothy D; Latenser, Barbara A; Lewis, Robert W; Kealey, Gerald P
2009-01-01
Abuse by burning is estimated to occur in 1 to 25% of children admitted with burn injuries annually. Hair and urine toxicology for illicit drug exposure may provide additional confirmatory evidence for abuse. To determine the impact of hair and urine toxicology on the identification of child abuse, we performed a retrospective chart review of all pediatric patients admitted to our burn unit. The medical records of 263 children aged 0 to 16 years of age who were admitted to our burn unit from January 2002 to December 2007 were reviewed. Sixty-five children had suspected abuse. Of those with suspected abuse, 33 were confirmed by the Department of Health and Human Services and comprised the study group. Each of the 33 cases was randomly matched to three pediatric (0-16 years of age) control patients (99). The average annual incidence of abuse in pediatric burn patients was 13.7+/-8.4% of total annual pediatric admissions (range, 0-25.6%). Age younger than 5 years, hot tap water cause, bilateral, and posterior location of injury were significantly associated with nonaccidental burn injury on multivariate analysis. Thirteen (39.4%) abused children had positive ancillary tests. These included four (16%) skeletal surveys positive for fractures and 10 (45%) hair samples positive for drugs of abuse (one patient had a fracture and a positive hair screen). In three (9.1%) patients who were not initially suspected of abuse but later confirmed, positive hair test for illicit drugs was the only indicator of abuse. Nonaccidental injury can be difficult to confirm. Although inconsistent injury history and burn injury pattern remain central to the diagnosis of abuse by burning, hair and urine toxicology offers a further means to facilitate confirmation of abuse.
Bladder cancer screening in aluminum smelter workers.
Taiwo, Oyebode A; Slade, Martin D; Cantley, Linda F; Tessier-Sherman, Baylah; Galusha, Deron; Kirsche, Sharon R; Donoghue, A Michael; Cullen, Mark R
2015-04-01
To present results of a bladder cancer screening program conducted in 18 aluminum smelters in the United States from January 2000 to December 2010. Data were collected on a cohort of workers with a history of working in coal tar pitch volatile exposed areas including urine analysis for conventional cytology and ImmunoCyt/uCyt+ assay. ImmunoCyt/uCyt+ and cytology in combination showed a sensitivity of 62.30%, a specificity of 92.60%, a negative predictive value of 99.90%, and a positive predictive value of 2.96%. Fourteen cases of bladder cancer were detected, and the standardized incidence ratio of bladder cancer was 1.18 (95% confidence interval, 0.65 to 1.99). Individuals who tested positive on either test who were later determined to be cancer free had undergone expensive and invasive tests. Evidence to support continued surveillance of this cohort has not been demonstrated.
Bladder Cancer Screening in Aluminum Smelter Workers
Taiwo, Oyebode A.; Slade, Martin D.; Cantley, Linda F.; Tessier-Sherman, Baylah; Galusha, Deron; Kirsche, Sharon R.; Donoghue, A. Michael
2015-01-01
Objective: To present results of a bladder cancer screening program conducted in 18 aluminum smelters in the United States from January 2000 to December 2010. Methods: Data were collected on a cohort of workers with a history of working in coal tar pitch volatile exposed areas including urine analysis for conventional cytology and ImmunoCyt/uCyt+ assay. Results: ImmunoCyt/uCyt+ and cytology in combination showed a sensitivity of 62.30%, a specificity of 92.60%, a negative predictive value of 99.90%, and a positive predictive value of 2.96%. Fourteen cases of bladder cancer were detected, and the standardized incidence ratio of bladder cancer was 1.18 (95% confidence interval, 0.65 to 1.99). Individuals who tested positive on either test who were later determined to be cancer free had undergone expensive and invasive tests. Conclusions: Evidence to support continued surveillance of this cohort has not been demonstrated. PMID:25525927
The Decanal Divide: Women in Decanal Roles at U.S. Medical Schools.
Schor, Nina F
2018-02-01
To test the hypotheses that women in medical school dean-level (decanal) positions occupy lower-rank and more image- and education-focused positions than men, and that state and woman-led schools have more women in decanal positions. Data were collected on September 10-18, 2016, from Web sites of 136 allopathic, U.S. medical schools accredited by the Liaison Committee on Medical Education and represented on the roster of accredited MD programs in the United States with full accreditation as of June 22, 2016. Statistical significance of differences between comparison groups was assessed using Student t test with P < .05 indicating significance. Correlation between parameters was determined by Spearman rank correlation test with P < .05 indicating significant correlation. Findings demonstrate that only 15% (22/149) of deans and interim deans are women, and the prevalence of women in decanal positions decreases with ascending professional rank (R = 0.93; P < .05). Women are most prevalent in decanal positions focusing on education and mentoring or institutional public image and least prevalent in those focusing on corporate strategy and policy, finance, or government relations. Schools with a woman as dean or interim dean have a higher percentage of decanal positions occupied by women than those with a man as dean or interim dean (P < .05). State and private medical schools do not differ from one another in this regard. Gender stereotypes and models appear to continue to drive the number and roles of women in decanal positions.
Loonen, Anne J. M.; de Jager, Cornelis P. C.; Tosserams, Janna; Kusters, Ron; Hilbink, Mirrian; Wever, Peter C.; van den Brule, Adriaan J. C.
2014-01-01
Molecular pathogen detection from blood is still expensive and the exact clinical value remains to be determined. The use of biomarkers may assist in preselecting patients for immediate molecular testing besides blood culture. In this study, 140 patients with ≥ 2 SIRS criteria and clinical signs of infection presenting at the emergency department of our hospital were included. C-reactive protein (CRP), neutrophil-lymphocyte count ratio (NLCR), procalcitonin (PCT) and soluble urokinase plasminogen activator receptor (suPAR) levels were determined. One ml EDTA blood was obtained and selective pathogen DNA isolation was performed with MolYsis (Molzym). DNA samples were analysed for the presence of pathogens, using both the MagicPlex Sepsis Test (Seegene) and SepsiTest (Molzym), and results were compared to blood cultures. Fifteen patients had to be excluded from the study, leaving 125 patients for further analysis. Of the 125 patient samples analysed, 27 presented with positive blood cultures of which 7 were considered to be contaminants. suPAR, PCT, and NLCR values were significantly higher in patients with positive blood cultures compared to patients without (p < 0.001). Receiver operating characteristic curves of the 4 biomarkers for differentiating bacteremia from non-bacteremia showed the highest area under the curve (AUC) for PCT (0.806 (95% confidence interval 0.699–0.913)). NLCR, suPAR and CRP resulted in an AUC of 0.770, 0.793, and 0.485, respectively. When compared to blood cultures, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for SepsiTest and MagicPlex Sepsis Test were 11%, 96%, 43%, 80%, and 37%, 77%, 30%, 82%, respectively. In conclusion, both molecular assays perform poorly when one ml whole blood is used from emergency care unit patients. NLCR is a cheap, fast, easy to determine, and rapidly available biomarker, and therefore seems most promising in differentiating BSI from non-BSI patients for subsequent pathogen identification using molecular diagnostics. PMID:24475269
Loonen, Anne J M; de Jager, Cornelis P C; Tosserams, Janna; Kusters, Ron; Hilbink, Mirrian; Wever, Peter C; van den Brule, Adriaan J C
2014-01-01
Molecular pathogen detection from blood is still expensive and the exact clinical value remains to be determined. The use of biomarkers may assist in preselecting patients for immediate molecular testing besides blood culture. In this study, 140 patients with ≥ 2 SIRS criteria and clinical signs of infection presenting at the emergency department of our hospital were included. C-reactive protein (CRP), neutrophil-lymphocyte count ratio (NLCR), procalcitonin (PCT) and soluble urokinase plasminogen activator receptor (suPAR) levels were determined. One ml EDTA blood was obtained and selective pathogen DNA isolation was performed with MolYsis (Molzym). DNA samples were analysed for the presence of pathogens, using both the MagicPlex Sepsis Test (Seegene) and SepsiTest (Molzym), and results were compared to blood cultures. Fifteen patients had to be excluded from the study, leaving 125 patients for further analysis. Of the 125 patient samples analysed, 27 presented with positive blood cultures of which 7 were considered to be contaminants. suPAR, PCT, and NLCR values were significantly higher in patients with positive blood cultures compared to patients without (p < 0.001). Receiver operating characteristic curves of the 4 biomarkers for differentiating bacteremia from non-bacteremia showed the highest area under the curve (AUC) for PCT (0.806 (95% confidence interval 0.699-0.913)). NLCR, suPAR and CRP resulted in an AUC of 0.770, 0.793, and 0.485, respectively. When compared to blood cultures, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for SepsiTest and MagicPlex Sepsis Test were 11%, 96%, 43%, 80%, and 37%, 77%, 30%, 82%, respectively. In conclusion, both molecular assays perform poorly when one ml whole blood is used from emergency care unit patients. NLCR is a cheap, fast, easy to determine, and rapidly available biomarker, and therefore seems most promising in differentiating BSI from non-BSI patients for subsequent pathogen identification using molecular diagnostics.
Position Accuracy Improvement by Implementing the DGNSS-CP Algorithm in Smartphones
Yoon, Donghwan; Kee, Changdon; Seo, Jiwon; Park, Byungwoon
2016-01-01
The position accuracy of Global Navigation Satellite System (GNSS) modules is one of the most significant factors in determining the feasibility of new location-based services for smartphones. Considering the structure of current smartphones, it is impossible to apply the ordinary range-domain Differential GNSS (DGNSS) method. Therefore, this paper describes and applies a DGNSS-correction projection method to a commercial smartphone. First, the local line-of-sight unit vector is calculated using the elevation and azimuth angle provided in the position-related output of Android’s LocationManager, and this is transformed to Earth-centered, Earth-fixed coordinates for use. To achieve position-domain correction for satellite systems other than GPS, such as GLONASS and BeiDou, the relevant line-of-sight unit vectors are used to construct an observation matrix suitable for multiple constellations. The results of static and dynamic tests show that the standalone GNSS accuracy is improved by about 30%–60%, thereby reducing the existing error of 3–4 m to just 1 m. The proposed algorithm enables the position error to be directly corrected via software, without the need to alter the hardware and infrastructure of the smartphone. This method of implementation and the subsequent improvement in performance are expected to be highly effective to portability and cost saving. PMID:27322284
Development and fabrication of heat-sterilizable inhalation therapy equipment
NASA Technical Reports Server (NTRS)
Irons, A. S.
1974-01-01
The development of a completely heat sterilizable intermittent positive pressure breathing (IPPB) ventilator in an effort to reduce the number of hospital acquired infections is reported. After appropriate changes in materials and design were made, six prototype units were fabricated and were successfully field tested in local hospitals. Most components of the modified ventilators are compatible with existing machines. In all but a few instances, such as installation of bacteria-retentive filters and a modified venturi, the change over from non-heat-sterilizable to sterilizable units was accomplished by replacement of heat labile materials with heat stable materials.
Sanchez, Marc-Antoine; Corcostégui, Simon-Pierre; De Broucker, Charles-Arnaud; Cabre, Olivier; Watier-Grillot, Stéphanie; Perelle, Sylvie; Ambert-Balay, Katia; Pommier de Santi, Vincent
2017-06-01
In February 2016, an outbreak of gastroenteritis occurred in a French military unit located in Poitiers, France. Attack rate was of 34% (103/300). A case-control study identified association between illness and cake consumption. Stool samples were tested positive for Norovirus GII.17 for one patient and one post-symptomatic food worker (FW). The FW presented vomiting one day before cake preparation. The NoV strain was probably spread through food worker hand contact. Prevention of Norovirus foodborne outbreaks implies new guidelines for FWs management in France and Europe.
Peng, Yi-Ling; Tenan, Matthew S; Griffin, Lisa
2018-06-01
Weakness of the vastus medialis oblique (VMO) has been proposed to explain the high prevalence of knee pain in female subjects. Clinicians commonly use exercises in an attempt to preferentially activate the VMO. Recently, our group found evidence to support clinical theory that the VMO is neurologically distinct from the vastus medialis (VM). However, the ability to voluntarily activate these muscle subsections is still disputed. The aim of this study was to determine if VM and VMO activation varies between sexes and if control of the two muscles is different between rehabilitation exercises. Thirteen men and 13 women performed isometric straight leg raises in two hip positions, neutral hip rotation and 30 degrees lateral hip rotation. Bipolar intramuscular fine-wire electrodes were inserted into the VM and VMO to obtain motor unit recruitment thresholds and initial firing rates at recruitment. Linear mixed models and Tukey post hoc tests were used to assess significant differences in 654 motor units. Women demonstrated faster motor unit firing rate at recruitment, 1.18 ± 0.56 Hz higher than men. Motor units fired 0.47 ± 0.19 Hz faster during neutral hip rotation compared with lateral hip rotation. The VMO motor units were recruited 2.92 ± 1.28% earlier than the VM. All motor units were recruited 3.74 ± 1.27% earlier during neutral hip rotation than lateral hip rotation. Thus the VM and the VMO can be activated differentially, and their motor unit recruitment properties are affected by sex and hip position. NEW & NOTEWORTHY This is the first study to reveal differential activation of the vastus medialis oblique from the vastus medialis in clinical exercise protocols. Our research group used fine-wire electrodes to examine EMG signals of the vastus medialis oblique and vastus medialis to avoid possible cross talk. We also consider the effect of sex on motor unit firing patterns because of higher prevalence of knee pain in women, and yet few studies evaluating the sex differences in neuromuscular control.
Results of EVA/mobile transporter space station truss assembly tests
NASA Technical Reports Server (NTRS)
Watson, Judith J.; Heard, Walter L., Jr.; Bush, Harold G.; Lake, M. S.; Jensen, J. K.; Wallsom, R. E.; Phelps, J. E.
1988-01-01
Underwater neutral buoyance tests were conducted to evaluate the use of a Mobile Transporter concept in conjunction with EVA astronauts to construct the Space Station Freedom truss structure. A three-bay orthogonal tetrahedral truss configuration with a 15 foot square cross section was repeatedly assembled by a single pair of pressure suited test subjects working from the Mobile Transporter astronaut positioning devices (mobile foot restraints). The average unit assembly time (which included integrated installation of utility trays) was 27.6 s/strut, or 6 min/bay. The results of these tests indicate that EVA assembly of space station size structures can be significantly enhanced when using a Mobile Transporter equipped with astronaut positioning devices. Rapid assembly time can be expected and are dependent primarily on the rate of translation permissible for on-orbit operations. The concept used to demonstate integrated installation of utility trays requires minimal EVA handling and consequentially, as the results show, has little impact on overall assembly time.
Mark, Barbara A; Hughes, Linda C; Belyea, Michael; Chang, Yunkyung; Hofmann, David; Jones, Cheryl B; Bacon, Cynthia T
2007-01-01
Hospital nurses have one of the highest work-related injury rates in the United States. Yet, approaches to improving employee safety have generally focused on attempts to modify individual behavior through enforced compliance with safety rules and mandatory participation in safety training. We examined a theoretical model that investigated the impact on nurse injuries (back injuries and needlesticks) of critical structural variables (staffing adequacy, work engagement, and work conditions) and further tested whether safety climate moderated these effects. A longitudinal, non-experimental, organizational study, conducted in 281 medical-surgical units in 143 general acute care hospitals in the United States. Work engagement and work conditions were positively related to safety climate, but not directly to nurse back injuries or needlesticks. Safety climate moderated the relationship between work engagement and needlesticks, while safety climate moderated the effect of work conditions on both needlesticks and back injuries, although in unexpected ways. DISCUSSION AND IMPACT ON INDUSTRY: Our findings suggest that positive work engagement and work conditions contribute to enhanced safety climate and can reduce nurse injuries.
[Gdansk HIV-AIDS project, yesterday, today and future].
Zielińska, W
1995-09-01
Medical care project for HIV positive and AIDS patients in Gdańsk voivodship was established in 1988 in the Clinic for Infectious Diseases of Gdańsk Medical University. The aim of this modern and multidirectional program was to provide full medical care for HIV/AIDS patients and introduce effective prophylaxis against spread of HIV infection. According to the project-clinical ward, outpatient clinic for HIV positive and AIDS patients, diagnostic and laboratory units, were established. Close cooperation including specialistic and general medical care, was set with detoxication ward, rehabilitation centers for drug addicts, prison medical services and the Korczak Orphanage. Education of medical staff and some social groups was provided (teachers, teenagers of secondary schools, journalists, police employees). Clinical ward for HIV positive patients who are in need of inpatient medical care is localized in the Clinic for Infectious Diseases of Gdańsk Medical University. The ward has 16 double - bed Melcer's boxes which are used for other HIV/AIDS patients according to present needs. Free beds are used for HIV negative patients. HIV/AIDS Outpatient Clinic is localized in Venerologic Outpatient Unit. This was because of some psychological, social, professional and organization aspects. Outpatient Clinic staff is responsible for first patients' examination. Serological diagnostics of HIV infection is follow up for everyone (anonymous testing is possible); testing for STD is available also. Diagnostic laboratory base for clinical ward and other units are the laboratories of Gdańsk Voivodship Hospital for Infectious Diseases. Clinic for Infectious Diseases supervises all co-operating units. These are the following: 10-beds detoxication ward for drug addicts in Psychiatric - Neurological Hospital "Srebrzysko", 70-80 places in rehabilitation centers for drug addicts in Zapowiednik and Smazyno, remand prison ward for HIV positive patients (this is the first ward established in Poland, thanks to our initiative, in 1990). One of very important units of our Center is the Korczak Orphanage for children aged 0-7 years, which is subjected to Voivodship Health Department. This orphanage is the place for children with positive HIV serology from the whole Poland. Children who need inpatient medical care, among them AIDS children, are admitted to the Clinic for Infectious Diseases and can be diagnosed and consulted in all units of Gdańsk Medical University. In 1992 the co-operation with Gdańsk homosexual society represented by the Gdańsk Initiative (a submit of Lambda organization), was established. Education program is the next very important part of the Clinical and Diagnostic HIV/AIDS Center work. Until now medical staff and Education Department staff were mainly concerned. It is planned to establish Voivodship Social Needs Outpatient Clinic which would continue all hitherto activities, which would be extended by social law counseling. Such outpatient clinic would facilitate education activity. It would be the base for medical research on social pathology and HIV/AIDS related problems.
Pérez, Alicia; Costa, María T; Cantoni, Gustavo; Mancini, Sergio; Mercapide, Carlos; Herrero, Eduardo; Volpe, Marcela; Araya, Daniel; Talmon, Gabriel; Chiosso, Carlos; Vázquez, Gabriela; Del Carpio, Mario; Santillan, Graciela; Larrieu, Edmundo
2006-01-01
The surveillance of infection for Echinococcus granulosus in the Province of Rio Negro during 1980-2002 included serological and ultrasonographic screening in humans and arecoline test in dogs. In lieu of the limitations of the arecoline test the proposal was to supplant that test for the copro ELISA-copro/Western Blot complex applied to feces collected from the environment. The objective was to compare the pros and cons of the two tests and to evaluate the human and the canine infection prevalence. The working area encompassed 7 Departments with systematic canine parasiticide activities (Program Area) and 4 Departments, not endemic, as Control Area. The arecoline test was applied to the dogs in assembled groups with the voluntary participation of their owners (not randomized sampling). Samples for the detection of coproantigens were obtained from sheep farms selected at random and analyzed by the complex copro-ELISA /Western Blot. Prevalence in man was determined by screening the school population (6 to 14 years old) by ultrasound, and by means of the compulsory notification of cases from the official system. Dogs (416) were tested with arecoline, 365 of which belonged to the Program Area. Of these 19 (5.2%) resulted positive, while none of 51 dogs from the Control Area were positive. Samples (748) of feces were tested to detect coproantigens, obtaining 37 positive samples within the Program Area and 4 within the Control Area. Farms (271) from the livestock estate unit were evaluated, out of which 236 belonged to the Program Area, gave 32 (13.6%) positive results, while 4 (11.4%) of 35 from the Control Area resulted positive. Sonography tests (7421) were done in the Program Area detecting 40 (0.5%) carriers, while in the Control Area, over 1732 tests, 9 (0.5%) resulted positive. The arecoline test provides information about the dog prevalence while the detection of coproantigens in feces collected from the environment allowed to enhance the quality of the information, and the identification of environments where specific control activities focusing on risk must be concentrated. Also the study allowed to recognize new transmission areas.
Grama, Daliane Faria; Casarotti, Leonardo da Silva; Morato, Michelle Gonçalves Vilela de Andrade; Silva, Lidyane Suellen; Mendonça, Daniella Fernandes; Limongi, Jean Ezequiel; Viana, João da Costa; Cury, Márcia Cristina
2013-09-01
Studies have revealed high prevalence rates of Trichomonas vaginalis in men and women worldwide. In Brazil, where reporting is not mandatory, the true prevalence rate is unknown. This study determined the prevalence of the parasite in women attending public health units in the city of Uberlândia, Minas Gerais, Brazil, identifying possible risk factors for infection, and also compared three diagnostic techniques for detecting the parasite. Samples of vaginal secretions collected from 742 women attending public health units were analyzed by direct wet mount examination, culture and smear test. Epidemiological questionnaires were administered. Of the total of 742 samples analyzed, 19 (2.6%) tested positive for T. vaginalis. The variables significantly associated with infection were: being of black ethnicity, smoking, having knowledge about sexually transmitted diseases and presenting clinical signs. The culture method was considered the gold standard test. Although there are programs to control other sexually transmitted diseases, there are none for trichomoniasis. The results of this study indicate the presence of T. vaginalis in the female population, and points to the need for more research in Brazil to gain a better understanding of the profile and epidemiology of the parasite.
Green, Edward; Hunt, Luke; Ross, J C Gareth; Nissen, Nina Marie; Curran, Tanya; Badhan, Anjna; Sutherland, Katherine A; Richards, Jade; Lee, James S; Allen, Samuel H; Laird, Steven; Blackman, Mandy; Collacott, Ian; Parker, Paul A; Walbridge, Andrew; Phillips, Rebecca; Sellu, Sia Jammie; Dama, Agnes; Sheriff, Alpha Karim; Zombo, Joseph; Ngegba, Doris; Wurie, Alieh H; Checchi, Francesco; Brooks, Timothy J
2016-09-01
In survivors of Ebola virus disease, clinical sequelae including uveitis, arthralgia, and fatigue are common and necessitate systematic follow-up. However, the infection risk to health-care providers is poorly defined. Here we report Ebola virus RT-PCR data for body site and fluid samples from a large cohort of Ebola virus survivors at clinic follow-up. In this cross-sectional cohort study, consecutive survivors of Ebola virus disease attending Kerry Town survivor clinic (Freetown, Sierra Leone), who had been discharged from the Kerry Town Ebola treatment unit, were invited to participate. We collected and tested axillary, blood, conjunctival, forehead, mouth, rectal, semen, urine, and vaginal specimens for presence of Ebola virus using RT-PCR. We regarded samples to be positive for Ebola virus disease if the cycle threshold was 40 or lower. We collected demographic data from survivors of their age, sex, time since discharge from the treatment unit, and length of acute admission in the Ebola treatment unit using anonymised standard forms. Between April 2, and June 16, 2015, of 151 survivors of Ebola virus disease invited to participate, 112 (74%) provided consent. The median age of participants was 21·5 years (IQR 14-31·5) with 34 (30%) participants younger than 16 years. 50 (45%) of 112 participants were male. We tested a total of 555 specimens: 103 from the axilla, 93 from blood, 92 from conjunctiva, 54 from forehead, 105 from mouth, 17 from the rectum, one from semen, 69 from urine, and 21 from the vagina. The median time from Ebola treatment unit discharge to specimen collection was 142 days (IQR 127-159). 15 participants had a total of 74 swabs taken less than 100 days from discharge. The semen sample from one participant tested positive for Ebola virus at 114 days after discharge from the treatment unit; specimens taken from the axilla, blood, conjunctiva, forehead, mouth, rectum, and urine of the same participant tested negative. All specimens from the other 111 participants tested negative. Patients recovering from Ebola virus disease who do not meet the case definition for acute disease pose a low infection risk to health-care providers 6 weeks after clearance of viraemia. Personal protective equipment after this time might be limited to standard barrier precautions, unless contact with fluids from sanctuary sites is envisaged. Save the Children International, Public Health England. Copyright © 2016 Elsevier Ltd. All rights reserved.
Helbling, A; McCants, M L; Musmand, J J; Schwartz, H J; Lehrer, S B
1996-07-01
As the consumption of fish increases in the United States, the importance of allergic reactions to fish has become clear. Since most previous studies on fish allergy have focused on children reacting mainly to codfish, there is a need to investigate allergic reactions to other fish in adults. To identify fish-allergic adults, and to assess cross-reactivity among different species of fish by RAST inhibition. Thirty-nine individuals who reported fish allergy were selected for study; 32 (82%) were atopic as defined by two or more positive skin tests to common inhalant allergens and a history of allergic reactions and 33 (85%) experienced allergic symptoms within 30 minutes after ingesting fish. The most frequently reported symptoms were hives (69%), itching (69%), and wheezing/chest tightness (54%). Study subjects were skin tested with fish extracts and their sera assayed for IgE antibodies to different fish species. Thirty-six (92%) of the subjects tested had a positive skin test to at least one of 17 fish extracts tested; 9/35 (26%) reacted to all 17 extracts. Of the atopic (two or more positive skin tests to common inhalant allergens plus a personal and/or family history of allergy) and nonatopic fish-tolerant controls, 20/26 (77%) reacted by skin test to one or more fish extracts tested; the most prevalent positive reaction was to anchovy (73%). A significant correlation (P < .01) was observed between skin test reactivity of fish-allergic subjects to most fish extracts and fish RAST reactions. Radioallergosorbent inhibition testing demonstrated significant cross-reactivity among pollack, salmon, trout, and tuna; and between mackerel and anchovy. These results suggest that fish-allergic subjects may be clinically sensitive to more than one species of fish. Skin test reactivity to fish by itself is not an adequate criterion for the confirmation of clinically relevant fish allergy; consequently, fish-allergic subjects with positive skin tests to several fish species should exercise caution when eating fish until tolerance can be demonstrated by double-blind, placebo-controlled food challenge, at the patient's earliest convenience.
Coca tea consumption causes positive urine cocaine assay.
Mazor, Suzan S; Mycyk, Mark B; Wills, Brandon K; Brace, Larry D; Gussow, Leon; Erickson, Timothy
2006-12-01
Coca tea, derived from the same plant that is used to synthesize cocaine, is commonly consumed in South America and easily obtained in the United States. To determine whether consumption of coca tea would result in a positive urine toxicology screen for cocaine metabolites. Five healthy adult volunteers consumed coca tea and underwent serial quantitative urine testing for cocaine metabolites by fluorescence polarization immunoassay. The cutoff for a positive assay was chosen at 300 ng/ml, the National Institute on Drug Abuse standard. Each participant's urine cocaine assay was positive (level exceeding 300 ng/ml) by 2 h after ingestion. Three out of five participants' samples remained positive at 36 h. Mean urine benzoylecgonine concentrations in all postconsumption samples was 1777 ng/ml (95% confidence interval: 1060-2495). Coca tea ingestion resulted in a positive urine assay for cocaine metabolite. Healthcare professionals should consider a history of coca tea ingestion when interpreting urine toxicology results.
Effect of Mandatory Unit and Individual Physical Training on Fitness in Military Men and Women.
Anderson, Morgan K; Grier, Tyson; Canham-Chervak, Michelle; Bushman, Timothy T; Nindl, Bradley C; Jones, Bruce H
2017-09-01
The purpose of this study was to look at the effect of additional individual physical training (PT) in addition to mandatory unit PT as well as other risk factors on physical fitness. A cross-sectional design. This study was conducted on a US military installation. Participants were 6290 male and 558 female active duty US Army soldiers in 3 light infantry brigades. Participants completed self-administered questionnaires asking about individual characteristics, PT, and physical fitness. Cut points were established for soldiers scoring within the top 33% for each of the 3 Army Physical Fitness Test events (2-mile run, sit-ups, and push-ups) and top 50% in each of the tests combined for overall performance. Odds ratios and 95% confidence intervals from multivariate analyses were calculated. Variables impacting physical fitness performance of men and women included increased body mass index, leading unit PT sessions, and individual distance running mileage. Other variables impacting physical performance for men included increased age, smoking, and individual resistance training. Soldiers performing additional individual PT demonstrated a positive influence on fitness compared to unit PT participation alone. Increased age and being overweight/obese negatively influenced physical fitness. To enhance fitness performance through unit PT, running by ability groups and resistance training should be encouraged by leadership.
NASA Astrophysics Data System (ADS)
Raitoharju, Matti; Nurminen, Henri; Piché, Robert
2015-12-01
Indoor positioning based on wireless local area network (WLAN) signals is often enhanced using pedestrian dead reckoning (PDR) based on an inertial measurement unit. The state evolution model in PDR is usually nonlinear. We present a new linear state evolution model for PDR. In simulated-data and real-data tests of tightly coupled WLAN-PDR positioning, the positioning accuracy with this linear model is better than with the traditional models when the initial heading is not known, which is a common situation. The proposed method is computationally light and is also suitable for smoothing. Furthermore, we present modifications to WLAN positioning based on Gaussian coverage areas and show how a Kalman filter using the proposed model can be used for integrity monitoring and (re)initialization of a particle filter.
Bozick, Robert; Malchiodi, Alessandro; Miller, Trey
2016-10-01
Using a nationally representative sample of 1,189 immigrant youth in American high schools, we examine whether the quality of education in their country of origin is related to post-migration math achievement in the 9th grade. To measure the quality of their education in the country of origin, we use country-specific average test scores from two international assessments: the Programme for International Student Assessment (PISA) and the Trends in International Mathematics and Science Study (TIMSS). We find that the average PISA or TIMSS scores for immigrant youth's country of origin are positively associated with their performance on the 9th grade post-migration math assessment. We also find that each year spent in the United States is positively associated with performance on the 9th grade post-migration math assessment, but this effect is strongest for immigrants from countries with low PISA/TIMSS scores.
Matsuya, Iwao; Katamura, Ryuta; Sato, Maya; Iba, Miroku; Kondo, Hideaki; Kanekawa, Kiyoshi; Takahashi, Motoichi; Hatada, Tomohiko; Nitta, Yoshihiro; Tanii, Takashi; Shoji, Shuichi; Nishitani, Akira; Ohdomari, Iwao
2010-01-01
We propose a novel sensor system for monitoring the structural health of a building. The system optically measures the relative-story displacement during earthquakes for detecting any deformations of building elements. The sensor unit is composed of three position sensitive detectors (PSDs) and lenses capable of measuring the relative-story displacement precisely, even if the PSD unit was inclined in response to the seismic vibration. For verification, laboratory tests were carried out using an Xθ-stage and a shaking table. The static experiment verified that the sensor could measure the local inclination angle as well as the lateral displacement. The dynamic experiment revealed that the accuracy of the sensor was 150 μm in the relative-displacement measurement and 100 μrad in the inclination angle measurement. These results indicate that the proposed sensor system has sufficient accuracy for the measurement of relative-story displacement in response to the seismic vibration.
Parsonnet, Jeffrey; Goering, Richard V; Hansmann, Melanie A; Jones, Michaelle B; Ohtagaki, Kumiko; Davis, Catherine C; Totsuka, Kyoichi
2008-08-01
Many cases of neonatal toxic shock syndrome (TSS)-like exanthematous disease but few cases of menstrual TSS (mTSS) have been reported in Japan. We determined the prevalence of mucosal colonization with Staphylococcus aureus and of positive antibodies to TSS toxin 1 (TSST-1) among 209 healthy Japanese women in Tokyo. S. aureus isolates from mucosal sites were characterized with respect to TSST-1 production and resistance genotype. Antibody titers were determined for test subjects and for 133 Japanese and 137 Caucasian control women living in the United States. S. aureus was isolated from at least one site in 108 of 209 women (52%) in Tokyo. Of the 159 S. aureus isolates recovered, 14 (9%) were TSST-1 positive (12 unique strains). Twelve of 209 women (6%) were colonized with a TSST-1-producing strain; two (<1%) had vaginal colonization. Only 2 of 12 unique toxigenic strains (14%) were methicillin resistant. Of the 12 TSST-1-positive strains isolated, 6 (50%) were pulsed-field gel electrophoresis type USA200, multilocus sequence type clonal complex 30. Fewer Japanese women in Tokyo (47%) than Caucasian and Japanese women in the United States (89% and 75%, respectively) had TSST-1 antibodies. The prevalences of colonization with TSST-1-producing S. aureus were comparable in Japan and the United States, despite low seropositivity to TSST-1 in Japan. Environmental factors appear to be important in promoting the development of anti-TSST-1 antibodies, as there was a significant difference in titers between Japanese women living in Tokyo and those living in the United States. Most colonizing TSST-1-producing S. aureus strains in Japan were genotypically similar to mTSS strains found in the United States.
ERIC Educational Resources Information Center
Hakanen, Jari J.; Perhoniemi, Riku; Toppinen-Tanner, Salla
2008-01-01
The present cross-lagged panel study aimed to investigate the energizing power of job resources and related gain spirals. Drawing on Hobfoll's Conservation of Resources (COR) theory's rarely tested assumptions of cumulative resource gains and gain spirals a reciprocal process was expected: (1) job resources lead to work engagement and work…
1996-05-22
S77-E-5073 (22 May 1996) --- From its position at 175 statute miles above Earth, the Space Shuttle Endeavour has encountered some colorful and attractive scenes heading into sunsets and sunrises. This particular encounter, captured with an Electronic Still Camera (ESC), occurred on flight day four, during which the six-member crew deployed the Passive Aerodynamically Stabilized Magnetically Damped Satellite (PAMS) - Satellite Test Unit (STU).
The uriscreen test to detect significant asymptomatic bacteriuria during pregnancy.
Teppa, Roberto J; Roberts, James M
2005-01-01
Asymptomatic bacteriuria (ASB) occurs in 2-11% of pregnancies and it is a clear predisposition to the development of acute pyelonephritis, which, in turn, poses risk to mother and fetus. Treatment of bacteriuria during pregnancy reduces the incidence of pyelonephritis. Therefore, it is recommended to screen for ASB at the first prenatal visit. The gold standard for detection of bacteriuria during pregnancy is urine culture, but this test is expensive, time-consuming, and labor-intensive. To determine the reliability of an enzymatic urine screening test (Uriscreen; Savyon Diagnostics, Ashdod, Israel) for detecting ASB in pregnancy. Catheterized urine samples were collected from 150 women who had routine prenatal screening for ASB. Patients with urinary symptoms, active vaginal bleeding, or who were previously on antibiotics therapy were excluded from the study. Sensitivity, specificity, and the positive and negative predictive values for the Uriscreen were estimated using urine culture as the criterion standard. Urine cultures were considered positive if they grew >10(5) colony-forming units of a single uropathogen. Twenty-eight women (18.7%) had urine culture results indicating significant bacteriuria, and 17 of these 28 specimens had positive enzyme activity. Of 122 samples with no growth, 109 had negative enzyme activity. Sensitivity, specificity, and positive and negative predictive values for the Uriscreen test were 60.7% (+/-18.1), 89.3% (+/-5.6), 56.6%, and 90.8%, respectively. The Uriscreen test had inadequate sensitivity for rapid screening of bacteriuria in pregnancy.
Oster, Alexandra M; Russell, Kate; Wiegand, Ryan E; Valverde, Eduardo; Forrest, David W; Cribbin, Melissa; Le, Binh C; Paz-Bailey, Gabriela
2013-01-01
In the United States, Latino men who have sex with men (MSM) are disproportionately affected by HIV. Latino MSM are a diverse group who differ culturally based on their countries or regions of birth and their time in the United States. We assessed differences in HIV prevalence and testing among Latino MSM by location of birth, time since arrival, and other social determinants of health. For the 2008 National HIV Behavioral Surveillance System, a cross-sectional survey conducted in large US cities, MSM were interviewed and tested for HIV infection. We used generalized estimating equations to test associations between various factors and 1) prevalent HIV infection and 2) being tested for HIV infection in the past 12 months. Among 1734 Latino MSM, HIV prevalence was 19%. In multivariable analysis, increasing age, low income, and gay identity were associated with HIV infection. Moreover, men who were U.S.-born or who arrived ≥5 years ago had significantly higher HIV prevalence than recent immigrants. Among men not reporting a previous positive HIV test, 63% had been tested for HIV infection in the past 12 months; recent testing was most strongly associated with having seen a health care provider and disclosing male-male attraction/sexual behavior to a health care provider. We identified several social determinants of health associated with HIV infection and testing among Latino MSM. Lower HIV prevalence among recent immigrants contrasts with higher prevalence among established immigrants and suggests a critical window of opportunity for HIV prevention, which should prioritize those with low income, who are at particular risk for HIV infection. Expanding health care utilization and encouraging communication with health care providers about sexual orientation may increase testing.
Bacteriological survey of frozen meat and gravy produced at establishments under federal inspection.
Surkiewicz, B F; Harris, M E; Johnston, R W
1973-10-01
During visits to 34 federally inspected establishments producing frozen meat and gravy, 541 production line samples and 535 finished product units were collected for bacteriological analyses. It was found that more than 70% of the sets of finished product (10 units/set) produced under good manufacturing practices had: (i) four or fewer coliform-positive units, (ii) two or fewer Escherichia coli-positive units, (iii) three or fewer Staphylococcus aureus-positive units, and (iv) an aerobic plate count of fewer than 50,000/g (geometric mean of 10 units). All finished product units were negative for salmonellae.
Bacteriological Survey of Frozen Meat and Gravy Produced at Establishments Under Federal Inspection
Surkiewicz, Bernard F.; Harris, Marshall E.; Johnston, Ralph W.
1973-01-01
During visits to 34 federally inspected establishments producing frozen meat and gravy, 541 production line samples and 535 finished product units were collected for bacteriological analyses. It was found that more than 70% of the sets of finished product (10 units/set) produced under good manufacturing practices had: (i) four or fewer coliform-positive units, (ii) two or fewer Escherichia coli-positive units, (iii) three or fewer Staphylococcus aureus-positive units, and (iv) an aerobic plate count of fewer than 50,000/g (geometric mean of 10 units). All finished product units were negative for salmonellae. PMID:4584595
Luchansky, John B; Chen, Yuhuan; Porto-Fett, Anna C S; Pouillot, Régis; Shoyer, Bradley A; Johnson-DeRycke, Rachel; Eblen, Denise R; Hoelzer, Karin; Shaw, William K; van Doren, Jane M; Catlin, Michelle; Lee, Jeehyun; Tikekar, Rohan; Gallagher, Daniel; Lindsay, James A; Dennis, Sherri
2017-06-01
A multiyear interagency Listeria monocytogenes Market Basket Survey was undertaken for selected refrigerated ready-to-eat foods purchased at retail in four FoodNet sites in the United States. Food samples from 16 food categories in six broad groups (seafood, produce, dairy, meat, eggs, and combination foods) were collected weekly at large national chain supermarkets and independent grocery stores in California, Maryland, Connecticut, and Georgia for 100 weeks between December 2010 and March 2013. Of the 27,389 total samples, 116 samples tested positive by the BAX PCR system for L. monocytogenes , and the pathogen was isolated and confirmed for 102 samples. Among the 16 food categories, the proportion of positive samples (i.e., without considering clustering effects) based on recovery of a viable isolate of L. monocytogenes ranged from 0.00% (95% confidence interval: 0.00, 0.18) for the category of soft-ripened and semisoft cheese to 1.07% (0.63, 1.68) for raw cut vegetables. Among the 571 samples that tested positive for Listeria-like organisms, the proportion of positive samples ranged from 0.79% (0.45, 1.28) for soft-ripened and semisoft cheese to 4.76% (2.80, 7.51) for fresh crab meat or sushi. Across all 16 categories, L. monocytogenes contamination was significantly associated with the four states (P < 0.05) but not with the packaging location (prepackaged by the manufacturer versus made and/or packaged in the store), the type of store (national chain versus independent), or the season. Among the 102 samples positive for L. monocytogenes , levels ranged from <0.036 most probable number per g to 6.1 log CFU/g. For delicatessen (deli) meats, smoked seafood, seafood salads, soft-ripened and semisoft cheeses, and deli-type salads without meat, the percentage of positive samples was significantly lower (P < 0.001) in this survey than that reported a decade ago based on comparable surveys in the United States. Use of mixed logistic regression models to address clustering effects with regard to the stores revealed that L. monocytogenes prevalence ranged from 0.11% (0.03, 0.34) for sprouts (prepackaged) to 1.01% (0.58, 1.74) for raw cut vegetables (prepackaged).
Nickell, Jason S; White, Brad J; Larson, Robert L; Renter, David G; Sanderson, Mike W
2011-03-01
Although numerous diagnostic tests are available to identify cattle persistently infected (PI) with Bovine viral diarrhea virus (BVDV) in cow-calf herds, data are sparse when evaluating the economic viability of individual tests or diagnostic strategies. Multiple factors influence BVDV testing in determining if testing should be performed and which strategy to use. A stochastic model was constructed to estimate the value of implementing various whole-herd BVDV cow-calf testing protocols. Three common BVDV tests (immunohistochemistry, antigen-capture enzyme-linked immunosorbent assay, and polymerase chain reaction) performed on skin tissue were evaluated as single- or two-test strategies. The estimated testing value was calculated for each strategy at 3 herd sizes that reflect typical farm sizes in the United States (50, 100, and 500 cows) and 3 probabilities of BVDV-positive herd status (0.077, 0.19, 0.47) based upon the literature. The economic value of testing was the difference in estimated gross revenue between simulated cow-calf herds that either did or did not apply the specific testing strategy. Beneficial economic outcomes were more frequently observed when the probability of a herd being BVDV positive was 0.47. Although the relative value ranking of many testing strategies varied by each scenario, the two-test strategy composed of immunohistochemistry had the highest estimated value in all but one herd size-herd prevalence permutation. These data indicate that the estimated value of applying BVDV whole-herd testing strategies is influenced by the selected strategy, herd size, and the probability of herd BVDV-positive status; therefore, these factors should be considered when designing optimum testing strategies for cow-calf herds.
A New Test Unit for Disintegration End-Point Determination of Orodispersible Films.
Low, Ariana; Kok, Si Ling; Khong, Yuet Mei; Chan, Sui Yung; Gokhale, Rajeev
2015-11-01
No standard time or pharmacopoeia disintegration test method for orodispersible films (ODFs) exists. The USP disintegration test for tablets and capsules poses significant challenges for end-point determination when used for ODFs. We tested a newly developed disintegration test unit (DTU) against the USP disintegration test. The DTU is an accessory to the USP disintegration apparatus. It holds the ODF in a horizontal position, allowing top-view of the ODF during testing. A Gauge R&R study was conducted to assign relative contributions of the total variability from the operator, sample or the experimental set-up. Precision was compared using commercial ODF products in different media. Agreement between the two measurement methods was analysed. The DTU showed improved repeatability and reproducibility compared to the USP disintegration system with tighter standard deviations regardless of operator or medium. There is good agreement between the two methods, with the USP disintegration test giving generally longer disintegration times possibly due to difficulty in end-point determination. The DTU provided clear end-point determination and is suitable for quality control of ODFs during product developmental stage or manufacturing. This may facilitate the development of a standardized methodology for disintegration time determination of ODFs. © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association.
Peterman, Jerusha Nelson; Silka, Linda; Bermudez, Odilia I; Wilde, Parke E; Rogers, Beatrice Lorge
2011-09-01
Refugees in the United States have higher rates of some chronic diseases than US-born residents or other first-generation immigrants. This may be partially a result of dietary practices in the United States. There is limited information about which factors are related to dietary practices in refugee populations, particularly those who have been in the United States for 10 to 20 years. Research with Cambodian communities may be useful for examining the relationship between refugee characteristics and dietary practices. Two focus groups (n=11) and a survey (n=150) of Cambodian refugee women were conducted in Lowell, MA, from 2007 to 2008. χ(2) analyses, t tests, and analysis of variance tests were used to describe differences in dietary practices (24-hour recall and a targeted qualitative food assessment) by group characteristics. Higher acculturation was related to higher likelihood of eating brown rice/whole grains, and to lower likelihood of eating high-sodium Asian sauces. Higher education was related to higher likelihood of eating vegetables and fruits and to eating white rice fewer times. Nutrition education and receiving dietary advice from a health care provider were related to higher likelihood of eating whole grains/brown rice. Having a child at home was related to a higher likelihood of eating fast food. Among Cambodian refugees who have been in the United States for 10 to 20 years, dietary practices appear to have a relationship with acculturation (positive association), the interrupted education common to refugees (negative association), nutrition education from either programs or health care providers (positive association), and having a child at home (negative association). Copyright © 2011 American Dietetic Association. Published by Elsevier Inc. All rights reserved.
Factors associated with Anaplasma spp. seroprevalence among dogs in the United States.
McMahan, Christopher S; Wang, Dongmei; Beall, Melissa J; Bowman, Dwight D; Little, Susan E; Pithua, Patrick O; Sharp, Julia L; Stich, Roger W; Yabsley, Michael J; Lund, Robert B
2016-03-22
Dogs in the United States are hosts to a diverse range of ticks and tick-borne pathogens, including A. phagocytophilum, an important emerging canine and human pathogen. Previously, a Companion Animal Parasite Council (CAPC)-sponsored workshop proposed factors purported to be associated with the infection risk for tick-transmitted pathogens in dogs in the United States, including climate conditions, socioeconomic characteristics, local topography, and vector distribution. Approximately four million test results from routine veterinary diagnostic tests from 2011-2013, which were collected on a county level across the contiguous United States, are statistically analyzed with the proposed factors via logistic regression and generalized estimating equations. Spatial prevalence maps of baseline Anaplasma spp. prevalence are constructed from Kriging and head-banging smoothing methods. All of the examined factors, with the exception of surface water coverage, were significantly associated with Anaplasma spp. prevalence. Overall, Anaplasma spp. prevalence increases with increasing precipitation and forestation coverage and decreases with increasing temperature, population density, relative humidity, and elevation. Interestingly, socioeconomic status and deer/vehicle collisions were positively and negatively correlated with canine Anaplasma seroprevalence, respectively. A spatial map of the canine Anaplasma hazard is an auxiliary product of the analysis. Anaplasma spp. prevalence is highest in New England and the Upper Midwest. The results from the two posited statistical models (one that contains an endemic areas assumption and one that does not) are in general agreement, with the major difference being that the endemic areas model estimates a larger prevalence in Western Texas, New Mexico, and Colorado. As A. phagocytophilum is zoonotic, the results of this analysis could also help predict areas of high risk for human exposure to this pathogen.
APOLLO I: Anticoagulation control in atrial fibrillation.
Pinho-Costa, Luís; Moreira, Sónia; Azevedo, Cristiana; Azevedo, Pedro; Castro, Elisabete; Sousa, Hélder; Melo, Miguel
2015-05-01
Anticoagulation control as assessed by time in therapeutic range (TTR) correlates positively with the safety and efficacy of thromboprophylaxis in atrial fibrillation. We set out to assess TTR in our unit and to investigate determinants of better control. This was a case series study of atrial fibrillation patients anticoagulated with warfarin or acenocoumarol at the Family Health Unit of Fânzeres. Sociodemographic and clinical data were collected and TTR was calculated by the Rosendaal method, based on international normalized ratio tests performed in external laboratories in the preceding six months. SPSS 21.0 was used for the statistical analysis, with descriptive statistics, Spearman's correlation, and the Mann-Whitney U and Kruskal-Wallis tests. Of the 106 eligible patients, 70% participated in the study. Median TTR was 65.3% (P25=48.3%, P75=86.8%). We found a positive association between this variable and duration of atrial fibrillation (ρ=0.477, p<0.001, r(2)=0.116) and with duration of anticoagulation (ρ=0.5, p<0.001, r(2)=0.087). No association was found with age, gender, educational level or existence of a caregiver (p>0.05). Median TTR in our unit is similar to that in southern European countries and close to the good control threshold (70%) proposed by the European Society of Cardiology. The duration of atrial fibrillation and of anticoagulation explains only a small part of the measure's variability. Other determinants of anticoagulation control must be investigated in future studies and comparative studies should be carried out in family health units monitoring anticoagulation on the premises. Copyright © 2014 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.
False-positive pregnancy test after transfusion of solvent/detergent-treated plasma.
Jilma-Stohlawetz, Petra; Wreford-Bush, Tim; Mills, Francesca; Davidson, Fiona; Kursten, Friedrich W; Jilma, Bernd; Birchall, Janet
2017-12-01
The transmission of pathogens, antibodies, and proteins is a possible consequence of blood product transfusion. A female patient had an unexpected positive serum β-human chorionic gonadotropin result, indicative of pregnancy, after she had received a transfusion with 1 unit of platelet concentrate, 4 units of red blood cells, and 4 units of pooled solvent/detergent-treated plasma (Octaplas). To investigate the possibility of passive transfusion of β-human chorionic gonadotropin from the plasma transfusion, one additional unit from the same batch was thawed and analyzed. To validate the β-human chorionic gonadotropin assay for use in solvent/detergent-treated plasma and to investigate any interference in the assay, dilution experiments were performed using the implicated plasma batch diluted with male and non-pregnant female sera. Also, plasma from a known pregnant woman was diluted with Octaplas (tested negative for β-human chorionic gonadotropin) and with a male serum to validate the assay for use in solvent/detergent-treated plasma. The implicated solvent/detergent-treated plasma had a mean β-human chorionic gonadotropin level of 91.5 mIU/mL. Results from the dilution experiments revealed an excellent correlation (r > 0.99) between β-human chorionic gonadotropin measurement in solvent/detergent-treated plasma and male serum and no over or under recovery of the expected results. Further measurements of β-human chorionic gonadotropin levels in the female recipient revealed an estimated half-life of 6 hours. This case demonstrates the importance of considering the possibility of passive transmission of analytes to a patient from the transfusion of blood products. Furthermore, the measurement of β-human chorionic gonadotropin is valid in solvent/detergent-treated plasma using a Roche Cobas analyzer. © 2017 AABB.
Reconnaissance On Chi-Square Test Procedure For Determining Two Species Association
NASA Astrophysics Data System (ADS)
Marisa, Hanifa
2008-01-01
Determining the assosiation of two species by using chi-square test has been published. Utility of this procedure to plants species at certain location, shows that the procedure could not find "ecologically" association. Tens sampling units have been made to record some weeds species in Indralaya, South Sumatera. Chi square test; Xt2 = N[|(ad)-(bc)|-(N/2)]2/mnrs (Eq:1) on two species (Cleome sp and Eleusine indica) of the weeds shows positive assosiation; while ecologically in nature, there is no relationship between them. Some alternatives are proposed to this problem; simplified chi-square test steps, make further study to find out ecologically association, or at last, ignore it.
Kim, Young Mee; Kang, Seung Wan; Kim, Se Young
2014-04-01
This research was an empirical study designed to identify precursors and interaction effects related to nurses' patient identification behavior. A multilevel analysis methodology was used. A self-report survey was administered to registered nurses (RNs) of a university hospital in South Korea. Of the questionnaires, 1114 were analyzed. The individual-level factors that had a significantly positive association with patient identification behavior were person-organization value congruence, organizational commitment, occupational commitment, tenure at the hospital, and tenure at the unit. Significantly negative group-level precursors of patient identification behavior were burnout climate and the number of RNs. Two interaction effects of the person-organization value congruence climate were identified. The first was a group-level moderating effect in which the negative relationship between the number of RNs and patient identification behavior was weaker when the nursing unit's value congruence climate was high. The second was a cross-level moderating effect in which the positive relationship between tenure at the unit and patient identification behavior was weaker when value congruence climate was high. This study simultaneously tested both individual-level and group-level factors that potentially influence patient identification behavior and identified the moderating role of person-organization value congruence climate. Implications of these results are discussed.
An investigation of the role of job satisfaction in employees' organizational citizenship behavior.
Talachi, Rahil Kazemi; Gorji, Mohammad Bagher; Boerhannoeddin, Ali Bin
2014-06-01
Job satisfaction, as an integral part of organizational environment, can affect organizational citizenship behavior. Therefore, the present paper aimed at determination of the relationship between these two factors among the employees to provide an appropriate model. The population of this study consisted of all employees of Golestan Province industry, mine and trade organization (Iran), the number of whom is 154, out of which, 120 employees were selected as a sample by the simple random sampling method. For collecting the data, two questionnaires of job satisfaction and organizational citizenship behavior were applied, and the obtained data was analyzed using the statistical methods of Kolmogorov-Smirnov test, Spearman's correlation, Pearson's correlation coefficient, Regression analysis, F-test and T-test. From the results, it was found that the variable of job satisfaction had a significant positive relationship with organizational citizenship behavior and one unit increase in organizational citizenship behavior is resulted from 0.622 unit increase in job satisfaction.
Selim, Najlaa A; Hmouda, Houssem T
2002-05-01
To assess the value of cardiac troponin I in the initial management of acute myocardial infarction and unstable angina, as well as the concordance between creatine phosphokinase-cardiac isoenzyme and cardiac troponin I. We reviewed retrospectively the charts of 32 patients with acute myocardial infarction or unstable angina admitted to the Intensive Care Unit from the Emergency Room of King Khalid Military City Hospital, Hafar-Al-Batin, Kingdom of Saudi Arabia from April 1998 to September 2000. The time of admission to the intensive care unit, which corresponds to the beginning of thrombolytic therapy, the time when cardiac enzymes (creatine phosphokinase-cardiac isoenzyme and cardiac troponin I) are available as well as number of cardiac troponin I determinations before obtaining a significant positive result (>2ng/ml) and the delay between admission and the first significant positive result of cardiac troponin I, were evaluated. Sixteen patients had confirmed acute myocardial infarction based on the association of typical chest pain, electrocardiographic findings with ST segment elevation and significant increase of the ratio creatine phosphokinase-cardiac isoenzyme/creatine phosphokinase > 10%. Sixteen patients had unstable angina and out of the 16 patients (81.25%) with acute myocardial infarction, 13 received thrombolytic therapy which was initiated on the basis of typical clinical history and electrocardiographic features, before the availability of cardiac enzymes. Troponin I was available in only 13 cases. The number of tests performed in these patients was 32. The first positive result of cardiac troponin I was available within a mean time of 16.66 20.8 hours from admission. The number of negative tests performed before obtaining a frank positive result was 9 in 12 patients. The number of positive tests after having obtained the first frank positive cardiac troponin I result was 10 in 12 patients. In all cases of cardiac troponin I, results were concordant with creatine phosphokinase-cardiac isoenzyme. In the 16 patients with unstable angina, only 11 patients had cardiac troponin I serum level. A total of 21 tests were performed. In 9 patients 14 cardiac troponin I tests were < 2 ng/ml. This was correlated with normal creatine phosphokinase-cardiac isoenzyme/creatine phosphokinase ratio. In 2 patients, 7 cardiac troponin I tests were positive. Both of them had significant increase of creatine phosphokinase-cardiac isoenzyme/creatine phosphokinase ratio and electrocardiographic features of myocardial ischemia and were referred for urgent coronary angiography. Cardiac troponin I levels are not helpful in the initial management of patients with acute myocardial infarction. Thrombolytic therapy should be therefore instituted before the availability of cardiac troponin I results. However, cardiac troponin I results are concordant with creatine phosphokinase-cardiac isoenzyme in retrospective confirmation of the diagnosis of acute myocardial infarction a few hours after onset. In patients with unstable angina, cardiac troponin I should be used mainly for risk stratification.
Doernberg, Sarah B; Lodise, Thomas P; Thaden, Joshua T; Munita, Jose M; Cosgrove, Sara E; Arias, Cesar A; Boucher, Helen W; Corey, G Ralph; Lowy, Franklin D; Murray, Barbara; Miller, Loren G; Holland, Thomas L
2017-03-15
Antimicrobial resistance in gram-positive bacteria remains a challenge in infectious diseases. The mission of the Gram-Positive Committee of the Antibacterial Resistance Leadership Group (ARLG) is to advance knowledge in the prevention, management, and treatment of these challenging infections to improve patient outcomes. Our committee has prioritized projects involving methicillin-resistant Staphylococcus aureus (MRSA) and vancomycin-resistant enterococci (VRE) due to the scope of the medical threat posed by these pathogens. Approved ARLG projects involving gram-positive pathogens include (1) a pharmacokinetics/pharmacodynamics study to evaluate the impact of vancomycin dosing on patient outcome in MRSA bloodstream infection (BSI); (2) defining, testing, and validating innovative assessments of patient outcomes for clinical trials of MRSA-BSI; (3) testing new strategies for "step-down" antibiotic therapy for MRSA-BSI; (4) management of staphylococcal BSIs in neonatal intensive care units; and (5) defining the impact of VRE bacteremia and daptomycin susceptibility on patient outcomes. This article outlines accomplishments, priorities, and challenges for research of infections caused by gram-positive organisms. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.
Marlowe, Elizabeth M; Hardy, David; Krevolin, Mark; Gohl, Peter; Bertram, Alexander; Arcenas, Rodney; Seiverth, Britta; Schneider, Tanja; Liesenfeld, Oliver
2017-09-01
We compared the analytical and clinical performance of cobas ® CT/NG for use on the Cobas ® 6800/8800 Systems with the Cobas ® 4800 CT/NG Test from urogenital and extragenital specimens in over 12,000 specimens from both male and female subjects in Germany and the United States. The analytical sensitivity was ≤40 EB/ml for Chlamydia trachomatis (CT) and ≤1 CFU/ml for Neisseria gonorrhoeae (NG). Using clinical specimens, the overall percent agreement with the Cobas ® 4800 CT/NG Test was >98.5%. Across urogenital specimens, there were 93 discrepant specimens; 76 (93.8%) of 81 CT discrepant specimens were 6800+/4800- and 10 (83.3%) of 12 NG discrepant specimens were 6800+/4800-. Sequencing verified CT results for 45 (61.6%) of 73 samples positive by 6800 and 1 (20%) of 5 positive by 4800. Similarly, 7 (70.0%) of 10 NG samples positive by 6800 and 1 of 2 positive by 4800 were confirmed by sequencing. Among discrepant extragenital specimens (all 6800+/4800-), 7 (50%) of 14 oropharyngeal and 23 (76.7%) of 30 anorectal CT discordant samples were confirmed as CT positive by sequencing; all 8 anorectal and 20 (90.9%) of 22 oropharyngeal NG discordant results were also confirmed as NG positive. In conclusion, Cobas ® CT/NG for use on the Cobas ® 6800/8800 Systems provides high-throughput automated solutions for sexually transmitted infection (STI) screening programs.
Dengue virus in blood donations, Puerto Rico, 2005.
Mohammed, Hamish; Linnen, Jeffrey M; Muñoz-Jordán, Jorge L; Tomashek, Kay; Foster, Gregory; Broulik, Amy S; Petersen, Lyle; Stramer, Susan L
2008-07-01
A single instance of transfusion-transmitted dengue infection has been reported. The high incidence of dengue in endemic countries, the high proportion of asymptomatic infection, and the median 5-day viremia, however, suggest that transfusion-associated dengue transmission may be more widespread than documented. The prevalence of dengue virus (DENV) RNA was determined in all blood donations to the American Red Cross in Puerto Rico from September 20 to December 4, 2005, using a specific type of nucleic acid amplification test called transcription-mediated amplification (TMA). TMA-positive donations were defined as those having two repeatedly reactive TMA results. TMA-positive donations were tested by enzyme-linked immunosorbent assay for immunoglobulin M (IgM) antibodies, by reverse transcription-polymerase chain reaction (RT-PCR), and by viral culture. Twelve (0.07%) of 16,521 blood donations tested were TMA-positive. Four were positive by RT-PCR (DENV serotypes 2 and 3). Virus was cultured from 3 of 4 RT-PCR-positive donations. One of the 12 TMA-positive donations was IgM-positive. Only 5 donations remained TMA-positive when diluted 1:16, as is done for routine minipool screening for other transfusion-transmissible viral infections (hepatitis C, human immunodeficiency, West Nile viruses [WNVs]). Nearly 1 in 1000 blood donations contained DENV RNA, and virus could be cultured from TMA-positive donations, suggesting a transfusion transmission risk similar to that which existed in the United States for WNV before universal donation screening. Similar to WNV, IgM antibody screening is likely to be ineffective, and some potentially infectious donations will be missed by minipool screening. Transfusion transmission should be considered in patients with dengue after blood transfusion.
Charbonneau, Audrey; Charette, Louis-Philippe; Rouleau, Geneviève; Savary, Mélissa; Wilson, Alexandra; Heer, Emily; Bériault, Karine; de Pokomandy, Alexandra
2018-03-23
Lyme disease is emerging in Canada. This study aimed to describe the use of serologic testing for the disease in the La Pommeraie health region in southern Quebec between 2012 and 2015 and to describe the clinical presentation of laboratory-confirmed cases. The medical charts of all patients investigated for Lyme disease at the Brome-Missisquoi-Perkins Hospital's laboratory between 2012 and 2015 were reviewed for results of serologic testing. Laboratory diagnosis was based on 2-tiered testing: cases had to have positive results of both the enzyme immunoassay and the Western blot test (IgM or IgG). We collected data on clinical presentation for patients assessed at the hospital or at the La Pommeraie Family Medicine Unit. Over the study period, 720 patients were investigated for Lyme disease. There was a more than fivefold increase in requests for serologic testing from 2012 (53) to 2015 (273). The number of confirmed cases increased from 2012 (3) to 2013 (19) and remained stable thereafter (19 in 2014, 18 in 2015). Fifty patients were positive for IgM with or without IgG positivity, and 9 patients were IgG-positive only. Chart reviews were completed for 278 of the 720 patients, including 38 of the 59 laboratory-confirmed cases. Among the 29 IgM-positive patients, the most common symptoms were fever (17 patients [59%]), fatigue (14 [48%]), myalgia (12 [41%]) and headaches (10 [34%]). Twenty-three (79%) had some cutaneous manifestation, including specifically erythema migrans (14 [48%]). A tick bite was reported by 11 patients (38%). Of the 44 patients in the entire study population who presented with erythema migrans, 15 (34%) had confirmed Lyme disease. Requests for serologic testing for Lyme disease increased in the La Pommeraie health region over recent years. Cutaneous manifestations, fever and myalgia were the most common symptoms of IgM-positive cases. Most patients did not report a tick bite. Copyright 2018, Joule Inc. or its licensors.
Charbonneau, Audrey; Charette, Louis-Philippe; Rouleau, Geneviève; Savary, Mélissa; Wilson, Alexandra; Heer, Emily; Bériault, Karine; de Pokomandy, Alexandra
2018-01-01
Background: Lyme disease is emerging in Canada. This study aimed to describe the use of serologic testing for the disease in the La Pommeraie health region in southern Quebec between 2012 and 2015 and to describe the clinical presentation of laboratory-confirmed cases. Methods: The medical charts of all patients investigated for Lyme disease at the Brome-Missisquoi-Perkins Hospital's laboratory between 2012 and 2015 were reviewed for results of serologic testing. Laboratory diagnosis was based on 2-tiered testing: cases had to have positive results of both the enzyme immunoassay and the Western blot test (IgM or IgG). We collected data on clinical presentation for patients assessed at the hospital or at the La Pommeraie Family Medicine Unit. Results: Over the study period, 720 patients were investigated for Lyme disease. There was a more than fivefold increase in requests for serologic testing from 2012 (53) to 2015 (273). The number of confirmed cases increased from 2012 (3) to 2013 (19) and remained stable thereafter (19 in 2014, 18 in 2015). Fifty patients were positive for IgM with or without IgG positivity, and 9 patients were IgG-positive only. Chart reviews were completed for 278 of the 720 patients, including 38 of the 59 laboratory-confirmed cases. Among the 29 IgM-positive patients, the most common symptoms were fever (17 patients [59%]), fatigue (14 [48%]), myalgia (12 [41%]) and headaches (10 [34%]). Twenty-three (79%) had some cutaneous manifestation, including specifically erythema migrans (14 [48%]). A tick bite was reported by 11 patients (38%). Of the 44 patients in the entire study population who presented with erythema migrans, 15 (34%) had confirmed Lyme disease. Interpretation: Requests for serologic testing for Lyme disease increased in the La Pommeraie health region over recent years. Cutaneous manifestations, fever and myalgia were the most common symptoms of IgM-positive cases. Most patients did not report a tick bite. PMID:29588280
Anechoic Chamber test of the Electromagnetic Measurement System ground test unit
NASA Astrophysics Data System (ADS)
Stevenson, L. E.; Scott, L. D.; Oakes, E. T.
1987-04-01
The Electromagnetic Measurement System (EMMS) will acquire data on electromagnetic (EM) environments at key weapon locations on various aircraft certified for nuclear weapons. The high-frequency ground unit of the EMMS consists of an instrumented B61 bomb case that will measure (with current probes) the localized current density resulting from an applied EM field. For this portion of the EMMS, the first system test was performed in the Anechoic Chamber Facility at Sandia National Laboratories, Albuquerque, New Mexico. The EMMS pod was subjected to EM radiation at microwave frequencies of 1, 3, and 10 GHz. At each frequency, the EMMS pod was rotated at many positions relative to the microwave source so that the individual current probes were exposed to a direct line-of-sight illumination. The variations between the measured and calculated electric fields for the current probes with direct illumination by the EM source are within a few db. The results obtained from the anechoic test were better than expected and verify that the high frequency ground portion of the EMMS will accurately measure the EM environments for which it was designed.
The risks associated with falling parts of glazed facades in case of fire
NASA Astrophysics Data System (ADS)
Sędłak, Bartłomiej; Kinowski, Jacek; Sulik, Paweł; Kimbar, Grzegorz
2018-05-01
Arguably, one of the most important requirement a building have to meet in case of fire is to ensure the safe evacuation of its users and the work of rescue teams. Consequently, issues related to the risks associated with falling parts of facades are fairly well known around Europe. Even though not equally well defined as other fire safety requirements concerning glazed facades, there is plenty of test methods for assessment of facades regarding falling parts, mostly based on an approach related to fire spread. In this paper selection of test method for assessment of facades regarding falling parts is briefly presented. However, focus of this work is on fire test of typical glazed segment of façade performed in ITB Laboratory. Results of the test positively verifies conjecture that solutions with glass units configured with thin, tempered glass panes on the outer side should pose no threat. However, the question has been raised whether the behaviour of other glass unit solutions (with additional coatings or laminated) would be similar.
Sedikides, Constantine; Gebauer, Jochen E
2010-02-01
In a meta-analysis, the authors test the theoretical formulation that religiosity is a means for self-enhancement. The authors operationalized self-enhancement as socially desirable responding (SDR) and focused on three facets of religiosity: intrinsic, extrinsic, and religion-as-quest. Importantly, they assessed two moderators of the relation between SDR and religiosity. Macro-level culture reflected countries that varied in degree of religiosity (from high to low: United States, Canada, United Kingdom). Micro-level culture reflected U.S. universities high (Christian) versus low (secular) on religiosity. The results were generally consistent with the theoretical formulation. Both macro-level and micro-level culture moderated the relation between SDR and religiosity: This relation was more positive in samples that placed higher value on religiosity (United States > Canada > United Kingdom; Christian universities > secular universities). The evidence suggests that religiosity is partly in the service of self-enhancement.
Howell, Peter; Au-Yeung, James; Pilgrim, Lesley
2007-01-01
Two important determinants of variation in stuttering frequency are utterance rate and the linguistic properties of the words being spoken. Little is known how these determinants interrelate. It is hypothesized that those linguistic factors that lead to change in word duration, alter utterance rate locally within an utterance that then gives rise to an increase in stuttering frequency. According to the hypothesis, utterance rate variation should occur locally within the linguistic segments in an utterance that is known to increase the likelihood of stuttering. The hypothesis is tested using length of tone unit as the linguistic factor. Three predictions are confirmed: Utterance rate varies locally within the tone units and this local variation affects stuttering frequency; stuttering frequency is positively related to the length of tone units; variations in utterance rate are correlated with tone unit length. Alternative theoretical formulations of these findings are considered. PMID:9921672
Methicillin-Resistant Staphylococcus aureus (MRSA) Detected at Four U.S. Wastewater Treatment Plants
Goldstein, Rachel E. Rosenberg; Micallef, Shirley A.; Gibbs, Shawn G.; Davis, Johnnie A.; He, Xin; George, Ashish; Kleinfelter, Lara M.; Schreiber, Nicole A.; Mukherjee, Sampa; Joseph, Sam W.
2012-01-01
Background: The incidence of community-acquired methicillin-resistant Staphylococcus aureus (CA-MRSA) infections is increasing in the United States, and it is possible that municipal wastewater could be a reservoir of this microorganism. To date, no U.S. studies have evaluated the occurrence of MRSA in wastewater. Objective: We examined the occurrence of MRSA and methicillin-susceptible S. aureus (MSSA) at U.S. wastewater treatment plants. Methods: We collected wastewater samples from two Mid-Atlantic and two Midwest wastewater treatment plants between October 2009 and October 2010. Samples were analyzed for MRSA and MSSA using membrane filtration. Isolates were confirmed using biochemical tests and PCR (polymerase chain reaction). Antimicrobial susceptibility testing was performed by Sensititre® microbroth dilution. Staphylococcal cassette chromosome mec (SCCmec) typing, Panton-Valentine leucocidin (PVL) screening, and pulsed field gel electrophoresis (PFGE) were performed to further characterize the strains. Data were analyzed by two-sample proportion tests and analysis of variance. Results: We detected MRSA (n = 240) and MSSA (n = 119) in 22 of 44 (50%) and 24 of 44 (55%) wastewater samples, respectively. The odds of samples being MRSA-positive decreased as treatment progressed: 10 of 12 (83%) influent samples were MRSA-positive, while only one of 12 (8%) effluent samples was MRSA-positive. Ninety-three percent and 29% of unique MRSA and MSSA isolates, respectively, were multidrug resistant. SCCmec types II and IV, the pvl gene, and USA types 100, 300, and 700 (PFGE strain types commonly found in the United States) were identified among the MRSA isolates. Conclusions: Our findings raise potential public health concerns for wastewater treatment plant workers and individuals exposed to reclaimed wastewater. Because of increasing use of reclaimed wastewater, further study is needed to evaluate the risk of exposure to antibiotic-resistant bacteria in treated wastewater. PMID:23124279
Survey of Obstetrician-Gynecologists in the United States About Toxoplasmosis
Dietz, Vance J.; Power, Michael; Lopez, Adriana; Wilson, Marianna; Navin, Thomas R.; Gibbs, Ronald; Schulkin, Jay
2001-01-01
Background: Although the incidence of toxoplasmosis is low in the United States, up to 6000 congenital cases occur annually. In September 1998, the Centers for Disease Control and Prevention held a conference about toxoplasmosis; participants recommended a survey of the toxoplasmosis-related knowledge and practices of obstetrician-gynecologists and the development of professional educational materials for them. Methods: In the fall of 1999, surveys were mailed to a 2% random sample of American College of Obstetricians and Gynecologists (ACOG) members and to a demographically representative group of ACOGmembers known as the Collaborative Ambulatory Research Network (CARN). Responses were not significantly different for the random and CARN groups for most questions (p value shown when different). Results: Among 768 US practicing ACOG members surveyed, 364 (47%) responded. Seven per cent (CARN 10%, random 5%) had diagnosed one or more case(s) of acute toxoplasmosis in the past year. Respondents were well-informed about how to prevent toxoplasmosis. However, only 12% (CARN 11%, random 12%) indicated that a positive Toxoplasma IgM test might be a false–positive result, and only 11% (CARN 14%, random 9%) were aware that the Food and Drug Administration sent an advisory to all ACOG members in 1997 stating that some Toxoplasma IgM test kits have high false–positive rates. Most of those surveyed (CARN 70%, random 59%; X2 p < 0.05) were opposed to universal screening of pregnant women. Conclusions: Many US obstetrician-gynecologists will encounter acute toxoplasmosis during their careers, but they are frequently uncertain about interpretation of the laboratory tests for the disease. Most would not recommend universal screening of pregnant women. PMID:11368255
Hermansson, Ulric; Helander, Anders; Brandt, Lena; Huss, Anders; Rönnberg, Sten
2002-01-01
Previous studies have shown that elevated, risky levels of alcohol consumption may lead to higher rates of sickness absence. However, no studies have examined the Alcohol Use Disorders Identification Test (AUDIT) or serum carbohydrate-deficient transferrin (CDT) in relation to sickness absence in the workplace. The purpose of this study was to examine the relationship between sick-days, 12 months before screening, and the AUDIT and CDT (CDTect kit). Serum gamma-glutamyltransferase also was used for comparison. The study was carried out over 36 months in a large workplace and formed part of an ongoing controlled study. In conjunction with a routine health examination, employees were offered the opportunity to undergo an alcohol screening. Absence data were obtained from the company payroll system, and sickness absence was analyzed by using a three-ordinal level cumulative logistic model on the number of sick-days. Odds ratios (OR) and 95% confidence intervals (CI) are reported. Of the 989 subjects who participated in the study, 193 (19.5%) screened positive in relation to either the AUDIT (>or=8 points) or CDT (<20 units/liter for men, and <27 units/liter for women), or both. Employees who screened positive with the AUDIT had a significantly higher proportion of sick-days (p = 0.047) compared with those who screened negative (OR = 1.4, CI 1.0-1.9). Neither long, continuous periods of sickness absence nor absence on Mondays or Fridays gave a clear indication of individuals who screened positive on the AUDIT or CDT test. Our data indicate that individuals with moderately elevated or risky levels of alcohol consumption show an increase in sick-days. Accordingly, workplaces have a good reason for using a more systematic approach to alcohol screening in routine workplace health examinations.
Flamm, Robert K; Rhomberg, Paul R; Huband, Michael D; Farrell, David J
2016-10-01
Delafloxacin, an investigational anionic fluoroquinolone, is active against a broad range of Gram-positive and Gram-negative bacteria. In this study, 200 Streptococcus pneumoniae (plus 30 levofloxacin-resistant isolates), 200 Haemophilus influenzae, and 100 Moraxella catarrhalis isolates selected primarily from the United States (2014) were tested against delafloxacin and comparator agents. Delafloxacin was the most potent agent tested. MIC50 and MIC90 values against all S. pneumoniae isolates were 0.008 and 0.015 μg/ml. Delafloxacin susceptibility was not affected by β-lactamase status against H. influenzae and M. catarrhalis. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Task and fatigue effects on low-threshold motor units in human hand muscle.
Enoka, R M; Robinson, G A; Kossev, A R
1989-12-01
1. The activity of single motor units was recorded in the first dorsal interosseus muscle of human subjects while they performed an isometric ramp-and-hold maneuver. Motor-unit activity was characterized before and after fatigue by the use of a branched bipolar electrode that was positioned subcutaneously over the test muscle. Activity was characterized in terms of the forces of recruitment and derecruitment and the discharge pattern. The purpose was to determine, before and after fatigue, whether motor-unit activity was affected by the direction in which the force was exerted. 2. Regardless of the task during prefatigue trials, interimpulse intervals were 1) more variable during increases or decreases in force than when force was held constant at the target value (4-6% above the recruitment force), and 2) more clustered around an arbitrary central value than would be expected with a normal (Gaussian) distribution. Both effects were seen during the flexion and abduction tasks. The behavior of low-threshold motor units in first dorsal interosseus is thus largely unaffected by the direction of the force exerted by the index finger. The absence of a task (i.e., a direction of force) effect suggests that the resultant force vector about the metacarpophalangeal joint of the index finger is not coded in terms of discrete populations of motor units, but, rather, it is based on the net muscle activity about the joint. 3. Motor-unit behavior during and after fatigue showed that the relatively homogeneous behavior seen before fatigue could be severely disrupted. The fatiguing protocol involved the continuous repetition, to the endurance limit, of a 15-s ramp-and-hold maneuver in which the abduction target force was 50% of maximum and was held for 10-s epochs (ramps up and down were approximately 2 s each). Motor-unit threshold was assessed by the forces of recruitment and derecruitment associated with each cycle of the fatigue test. Changes in recruitment force during the protocol were either minimal or, when present, not systematic. In contrast, the derecruitment force of all units exhibited a marked and progressive increase over the course of the test. 4. After the fatigue test, when the initial threshold tasks were repeated, the behavior of most motor units changed. These changes included the derecruitment of previously active motor units, the recruitment of additional motor units, and an increased discharge variability of units that remained recruited. The variation in recruitment order seemed to be much greater than that reported previously for nonfatiguing conditions.(ABSTRACT TRUNCATED AT 400 WORDS)
Madhivanan, Purnima; Krupp, Karl; Kulkarni, Vinay; Kulkarni, Sanjeevani; Vaidya, Neha; Shaheen, Reshma; Philpott, Sean; Fisher, Celia
2014-03-24
In India, approximately 49,000 women living with HIV become pregnant and deliver each year. While the government of India has made progress increasing the availability of prevention of mother-to-child transmission of HIV (PMTCT) services, only about one quarter of pregnant women received an HIV test in 2010, and about one-in-five that were found positive for HIV received interventions to prevent vertical transmission of HIV. Between February 2012 to March 2013, 14 HIV-positive women who had recently delivered a baby were recruited from HIV positive women support groups, Government of India Integrated Counseling and Testing Centers, and nongovernmental organizations in Mysore and Pune, India. In-depth interviews were conducted to examine their general experiences with antenatal healthcare; specific experiences around HIV counseling and testing; and perceptions about their care and follow-up treatment. Data were analyzed thematically using the human rights framework for HIV testing adopted by the United Nations and India's National AIDS Control Organization. While all of the HIV-positive women in the study received HIV and PMTCT services at a government hospital or antiretroviral therapy center, almost all reported attending a private clinic or hospital at some point in their pregnancy. According to the participants, HIV testing often occurred without consent; there was little privacy; breaches of confidentiality were commonplace; and denial of medical treatment occurred routinely. Among women living with HIV in this study, violations of their human rights occurred more commonly in private rather than public healthcare settings. There is an urgent need for capacity building among private healthcare providers to improve standards of practice with regard to informed consent process, HIV testing, patient confidentiality, treatment, and referral of pregnant women living with HIV.
Glutathione peroxidase level in patients with Helicobacter pylori-associated gastritis
NASA Astrophysics Data System (ADS)
Tala, Z. Z.; Siregar, G. A.; Siregar, G. P.
2018-03-01
Helicobacter pylori (H. pylori) associated with the generation of reactive oxygen species (ROS), with leads to oxidative stress in the gastric mucosa. GPX is one of human antioxidative defense system allows the elimination of excess ROS. A cross-sectional study was in 80 consecutive gastritis patients who came to the endoscopic unit of Adam Malik General Hospital and PermataBunda Hospital in Medan, Indonesia, from May–September 2017, to determine the difference of GPX serum level between positive and negative infected H. pylori. the diagnosis of gastritis used Histopathology. Rapid urease test for diagnosis of H. pylori infection. Serum samples were obtained to determined circulating GPX. It used Univariate and bivariate analysis (Mann Whitney U test). There were 50 patients (62.5%) infected with H. pylori. GPX levels in patients with positive H. pylori gastritis were lower than those of negative H. pylori but did not differ significantly. In conclusion, there were no significant differences in GPX level between positive and negative infected H. pylori patients.
1985-01-01
Anti-HTLV III had been detected in 12,689 serum samples collected within August 1985 from 12 Transfusion Centres of Liguria. In the course of the first test, carried out by ELISA using disrupted virions as antigen, 12,666 samples (99.81%) resulted non reactive; 14 (0.1%) belonged to the grey-zone and 9 (0.08%) were clearly reactive. The samples of the last two classes were tested again in the same way and, whenever the cases were suspect as positive, by Western-blot technique. All positive cases, but three, were linked with risk factors such as intravenous drug use or drug addicts partners. Even if the prevalence of blood donors anti-HTLV III positive resulted, on the whole, very low (0.063%), the investigations carried out prove the importance of regular screening of blood units for the prevention of HTLV III infection.
Spence Laschinger, Heather K; Fida, Roberta
2015-05-01
A model linking authentic leadership, structural empowerment, and supportive professional practice environments to nurses' perceptions of patient care quality and job satisfaction was tested. Positive work environment characteristics are important for nurses' perceptions of patient care quality and job satisfaction (significant factors for retention). Few studies have examined the mechanism by which these characteristics operate to influence perceptions of patient care quality or job satisfaction. A cross-sectional provincial survey of 723 Canadian nurses was used to test the hypothesized models using structural equation modeling. The model was an acceptable fit and all paths were significant. Authentic leadership had a positive effect on structural empowerment, which had a positive effect on perceived support for professional practice and a negative effect on nurses' perceptions that inadequate unit staffing prevented them from providing high-quality patient care. These workplace conditions predicted job satisfaction. Authentic leaders play an important role in creating empowering professional practice environments that foster high-quality care and job satisfaction.
Ayres, Cynthia; Mahat, Ganga; Atkins, Robert
2013-01-01
To examine variables influencing the positive health practices (PHP) of Filipino college students to gain a better understanding of health practices in this ethnic/racial group. Cross-sectional study tested theoretical relationships postulated among (a) PHP, (b) social support (SS), (c) optimism, and (d) acculturation. A sample of Filipino college students (N = 226) aged 18 to 21 was obtained in June 2009. Participants completed 4 instruments. Statistical analyses were performed using SPSS 16.0. Positive correlations were found between PHP and SS (r = .39, p = .01) and optimism and PHP (r = .36, p = .01). No correlation was found between PHP and acculturation. Optimism and SS predicted performance of PHP (R (2) = .18, F[2, 221] = 24.927, p < .001). A difference was found in acculturation levels between participants who grew up in the United States (t[223] = 4.5, p < .001) and those who did not. Findings help health practitioners and educators to better understand the underlying factors that influence PHP in this population.
Integrating Routine HIV Screening in the New York City Community Health Center Collaborative.
Rodriguez, Vanessa; Lester, Deborah; Connelly-Flores, Alison; Barsanti, Franco A; Hernandez, Paloma
2016-01-01
One in seven of the 1.1 million people living in the United States infected with HIV are not aware of their HIV status. At the same time, many clinical settings have not adopted routine HIV screening, which promotes linkage to specialist medical care. We sought to improve HIV screening in a large community health center network by using a data-driven, collaborative learning approach and system-wide modifications, where counselor-based HIV screening and testing were replaced by health-care providers and medical assistants. Urban Health Plan, Inc., a network of federally qualified health centers in the boroughs of the Bronx and Queens in New York City, provided HIV screening training for its health-care providers. In January 2011, it modified its electronic medical record system to incorporate HIV test offering. This study compared the 2010 baseline year with the three-year implementation follow-up period (January 2011 through December 2013) to determine the number of eligible individuals for HIV testing, HIV tests offered and performed, HIV-positive individuals, and HIV cases linked to specialty care. A total of 26,853 individuals at baseline and 100,369 individuals in the implementation period were eligible for HIV testing. HIV testing was performed on 2,079 (8%) of 26,853 eligible individuals in 2010 and 49,646 (50%) of 100,369 eligible individuals from 2011 through 2013. HIV-positive status was determined in 19 (0.9%) of 2,079 tested individuals in 2010 and 166 (0.3%) of 49,646 tested individuals from 2011 through 2013. Linkage to care was observed in all 19 eligible individuals and 127 (77%) of 166 eligible individuals who tested HIV positive in 2010 and 2011-2013, respectively. This study enabled routine HIV implementation testing at a community health center network, which resulted in enhanced HIV testing, an increased number of HIV-positive cases identified, and a rise in the number of patients linked to HIV specialist care.
[Tuberculin sensitivity in infants and preschool children].
Guseva, E M; Efimova, E P; Stepankina, T T; Chernyshova, L V
2001-01-01
Marked fluctuations in sensitivity to tuberculin related to the time of nonspecific vaccinations were found in children aged 1 to 7 years vaccinated with BCG within the first week of life in annual Mantoux test (2 tuberculin units). At the age of 3 and 7 years vaccinations raise sensitivity to tuberculin causing a rise in positive reactions to tuberculin. This indicates changes in postvaccination allergy to BCG.
ERIC Educational Resources Information Center
Wagstaff, David A.; Elek, Elvira; Kulis, Stephen; Marsiglia, Flavio
2009-01-01
A nonparametric bootstrap was used to obtain an interval estimate of Pearson's "r," and test the null hypothesis that there was no association between 5th grade students' positive substance use expectancies and their intentions to not use substances. The students were participating in a substance use prevention program in which the unit of…
Toxoplasmosis in sand fox (Vulpes rueppelli).
Pas, An; Dubey, J P
2008-08-01
Fatal toxoplasmosis was diagnosed in a sand fox (Vulpes rueppelli) from United Arab Emirates. Toxoplasma gondii-like tachyzoites were found associated with necrosis in the intestine, spleen, liver, pancreas, lungs, mesenteric lymph nodes, and heart. Tachyzoites reacted positively with T. gondii-specific polyclonal antibodies. Antibodies to T. gondii were detected in 8 captive V. rueppelli assayed by the modified direct agglutination test in titers of 1:800 or higher.
40 CFR 86.144-94 - Calculations; exhaust emissions.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) For SI units, ER06OC93.062 Where: (x) Vo = Volume of gas pumped by the positive displacement pump, in... displacement pump during test, °R(°K). (8)(i) NMHCconc = HCconc − (rCH4 × CH4conc). (ii) DensityNMHC = The... determined from the following: (1) Total hydrocarbon mass: HCmass = Vmix × DensityHC × (HCconc/1,000,000) (2...
ERIC Educational Resources Information Center
Johnson, Steven W.
2013-01-01
A study using 454 respondents recruited through SurveyMonkey were used to quantitatively test whether age or ethical position is better able to predict purchasing rates for digital music acquisition. The respondents had an age range from 18 to 80 and lived in the United States. The sample had a diverse and representative geographic and economic…
A Multicomponent Fall Prevention Strategy Reduces Falls at an Academic Medical Center.
France, Dan; Slayton, Jenny; Moore, Sonya; Domenico, Henry; Matthews, Julia; Steaban, Robin L; Choma, Neesha
2017-09-01
While the reduction in fall rates has not kept pace with the reduction of other hospital-acquired conditions, patient safety research and quality improvement (QI) initiatives at the system and hospital levels have achieved positive results and provide insights into potentially effective risk reduction strategies. An academic medical center developed a QI-based multicomponent strategy for fall prevention and pilot tested it for six months in three high-risk units-the Neuroscience Acute Care Unit, the Myelosuppression/Stem Cell Transplant Unit, and the Acute Care for the Elderly Unit-before implementing and evaluating the strategy hospitalwide. The multicomponent fall strategy was evaluated using a pre-post study design. The main outcome measures were falls and falls with harm measured in events per 1,000 patient-days. Fall rates were monitored and compared for three classes of falls: (1) accidental, (2) anticipated physiologic, and (3) unanticipated physiologic. Statistical process control charts showed that the pilot units had achieved significant reductions in falls with harm during the last five months of data collection. Wald test and segmented regression analyses revealed significant improvements in pooled postintervention fall rates, stratified by fall type. The hospitalwide implementation of the program resulted in a 47% overall reduction in falls in the postintervention period. A fall prevention strategy that targeted the spectrum of risk factors produced measurable improvement in fall rates and rates of patient harm. Hospitals must continue developing, rigorously testing, and sharing their results and experiences in implementing and sustaining multicomponent fall prevention strategies. Copyright © 2017 The Joint Commission. Published by Elsevier Inc. All rights reserved.
Davis, Alissa; Dasgupta, Anindita; Goddard-Eckrich, Dawn; El-Bassel, Nabila
2016-10-01
The United States has a large community supervision population, a growing number of whom are women. Trichomonas vaginalis infection is strongly associated with an increased risk of human immunodeficiency virus (HIV) acquisition and transmission, particularly among women, but there is a paucity of research on HIV and T. vaginalis co-infection among women under community supervision. This article examines the prevalence of T. vaginalis infection and T. vaginalis and HIV coinfection at baseline among women under community supervision in New York City. It also examines the 12-month outcomes of women treated for T. vaginalis. Women received biological tests for HIV and T. vaginalis at baseline and 12 months follow-up. Of the 333 women tested for sexually transmitted infections, 77 women (23.1%) tested positive for T. vaginalis at baseline and 44 (13.3%) were HIV positive. Human immunodeficiency virus-positive women had significantly higher rates of T. vaginalis infection than HIV-negative women (36.4% vs 21.3%, P ≤ 0.05). Sixteen women (4.8%) were coinfected with T. vaginalis and HIV. Of the 77 women who were positive for T. vaginalis infection at baseline, 58 (75.3%) received treatment by a health care provider. Of those who received treatment, 17 (29.3%) tested positive for T. vaginalis at the 12-month follow-up. Given the high prevalence of T. vaginalis among this sample of women, particularly among HIV-positive women, and high levels of reinfection or persistent infection, screening for T. vaginalis among women under community supervision may have a substantial impact on reducing HIV acquisition and transmission among this high-risk population.
2008-06-06
Human brucellosis, a nationally notifiable disease, is uncommon in the United States. Most human cases have occurred in returned travelers or immigrants from regions where brucellosis is endemic, or were acquired domestically from eating illegally imported, unpasteurized fresh cheeses. In January 2005, a woman aged 35 years who lived in Nassau County, Florida, received a diagnosis of brucellosis, based on results of a Brucella immunoglobulin M (IgM) enzyme immunoassay (EIA) performed in a commercial laboratory using analyte specific reagents (ASRs); this diagnosis prompted an investigation of dairy products in two other states. Subsequent confirmatory antibody testing by Brucella microagglutination test (BMAT) performed at CDC on the patient's serum was negative. The case did not meet the CDC/Council of State and Territorial Epidemiologists' (CSTE) definition for a probable or confirmed brucellosis case, and the initial EIA result was determined to be a false positive. This report summarizes the case history, laboratory findings, and public health investigations. CDC recommends that Brucella serology testing only be performed using tests cleared or approved by the Food and Drug Administration (FDA) or validated under the Clinical Laboratory Improvement Amendments (CLIA) and shown to reliably detect the presence of Brucella infection. Results from these tests should be considered supportive evidence for recent infection only and interpreted in the context of a clinically compatible illness and exposure history. EIA is not considered a confirmatory Brucella antibody test; positive screening test results should be confirmed by Brucella-specific agglutination (i.e., BMAT or standard tube agglutination test) methods.
Fredrickson, Barbara L.; Tugade, Michele M.; Waugh, Christian E.; Larkin, Gregory R.
2009-01-01
Extrapolating from B. L. Fredrickson's (1998, 2001) broaden-and-build theory of positive emotions, the authors hypothesized that positive emotions are active ingredients within trait resilience. U.S. college students (18 men and 28 women) were tested in early 2001 and again in the weeks following the September 11th terrorist attacks. Mediational analyses showed that positive emotions experienced in the wake of the attacks— gratitude, interest, love, and so forth—fully accounted for the relations between (a) precrisis resilience and later development of depressive symptoms and (b) precrisis resilience and postcrisis growth in psychological resources. Findings suggest that positive emotions in the aftermath of crises buffer resilient people against depression and fuel thriving, consistent with the broaden-and-build theory. Discussion touches on implications for coping. PMID:12585810
Needle puncture in rabbit functional spinal units alters rotational biomechanics.
Hartman, Robert A; Bell, Kevin M; Quan, Bichun; Nuzhao, Yao; Sowa, Gwendolyn A; Kang, James D
2015-04-01
An in vitro biomechanical study for rabbit lumbar functional spinal units (FSUs) using a robot-based spine testing system. To elucidate the effect of annular puncture with a 16 G needle on mechanical properties in flexion/extension, axial rotation, and lateral bending. Needle puncture of the intervertebral disk has been shown to alter mechanical properties of the disk in compression, torsion, and bending. The effect of needle puncture in FSUs, where intact spinal ligaments and facet joints may mitigate or amplify these changes in the disk, on spinal motion segment stability subject to physiological rotations remains unknown. Rabbit FSUs were tested using a robot testing system whose force/moment and position precision were assessed to demonstrate system capability. Flexibility testing methods were developed by load-to-failure testing in flexion/extension, axial rotation, and lateral bending. Subsequent testing methods were used to examine a 16 G needle disk puncture and No. 11 blade disk stab (positive control for mechanical disruption). Flexibility testing was used to assess segmental range-of-motion (degrees), neutral zone stiffness (N m/degrees) and width (degrees and N m), and elastic zone stiffness before and after annular injury. The robot-based system was capable of performing flexibility testing on FSUs-mean precision of force/moment measurements and robot system movements were <3% and 1%, respectively, of moment-rotation target values. Flexibility moment targets were 0.3 N m for flexion and axial rotation and 0.15 N m for extension and lateral bending. Needle puncture caused significant (P<0.05) changes only in flexion/extension range-of-motion and neutral zone stiffness and width (N m) compared with preintervention. No. 11 blade-stab significantly increased range-of-motion in all motions, decreased neutral zone stiffness and width (N m) in flexion/extension, and increased elastic zone stiffness in flexion and lateral bending. These findings suggest that disk puncture and stab can destabilize FSUs in primary rotations.
Nickel and cobalt release from children's toys purchased in Denmark and the United States.
Jensen, Peter; Hamann, Dathan; Hamann, Carsten R; Jellesen, Morten S; Jacob, Sharon E; Thyssen, Jacob P
2014-01-01
Nickel is the most common allergen detected by patch testing in children. There is an increasing number of cases in children who have not had exposure to piercing. Although the clinical relevance of nickel patch test reactions in children is sometimes uncertain, continued vigilance to identify new sources of nickel exposure in this age group is important. Recent case reports have described allergic nickel contact dermatitis in children following exposure to toys, but the magnitude of this problem is unknown. The aim of this study was to evaluate nickel and cobalt release from children's toys. We purchased 212 toys in 18 different retail and online stores in the United States and Denmark. Nickel and cobalt release was tested using the dimethylglyoxime and cobalt screening spot tests. A total of 73 toys (34.4%) released nickel, and none released cobalt. Toys are a commonly overlooked source of nickel exposure and sensitization. Therefore, dermatologists, allergists, and pediatricians should consider the role of toys in their evaluation of children with dermatitis, and the parents of children with positive nickel patch test reactions should be told that toys may release nickel and be a potential chemical source in the manifestation of allergic contact dermatitis.
NASA Astrophysics Data System (ADS)
Pu, Yang; Wang, Wubao; Tang, Guichen; Budansky, Yury; Sharonov, Mikhail; Xu, Min; Achilefu, Samuel; Eastham, James A.; Alfano, Robert R.
2012-01-01
A portable near infrared scanning polarization imaging unit with an optical fiber-based rectal probe, namely Photonic Finger, was designed and developed o locate the 3D position of abnormal prostate site inside normal prostate tissue. An inverse algorithm, Optical Tomography using Independent Component Analysis (OPTICA) was improved particularly to unmix the signal from targets (cancerous tissue) embedded in a turbid medium (normal tissue) in the backscattering imaging geometry. Photonic Finger combined with OPTICA was tested to characterize different target(s) inside different tissue medium, including cancerous prostate tissue embedded by large piece of normal tissue.
Celiac disease serum markers and recurrent pregnancy loss.
Sharshiner, Rita; Romero, Stephanie T; Bardsley, Tyler R; Branch, D Ware; Silver, Robert M
2013-12-01
Celiac disease has been associated with numerous unfavorable health outcomes, including pregnancy complications such as infertility, preterm birth, and preeclampsia. However, the association between celiac disease and recurrent pregnancy loss (RPL) remains uncertain. Our purpose was to compare serum markers of celiac disease in women with and without RPL. Therefore, we performed a case-control study of 116 women with unexplained recurrent pregnancy loss and 116 age-matched controls. Maternal sera were analyzed for immunoglobulin A (IgA) and immunoglobulin G (IgG) tissue transglutaminase (tTG) antibodies and endomysial (EM) antibodies. Groups were similar with regard to age, race and ethnicity, and BMI. One case and one control tested positive (≥20 Units) for IgA tTG antibodies and mean levels of IgA tTG antibodies were similar in cases and controls (5.5±2.86 versus 6.0±12.45; p=0.16). No cases or controls were positive for IgG tTG antibodies. However, cases had higher levels of IgG tTG antibody compared with controls (4.0±2.40 versus 3.3±1.30; p=0.0064). One subject (a control) tested positive for IgA EM antibodies and no subjects tested positive for IgG EM antibodies. In conclusion, positive results for tTG and EM antibodies were similar in women with and without RPL. Given these results, testing for occult celiac disease is not recommended in the evaluation of women with idiopathic RPL. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Qvarnstrom, Yvonne; Bishop, Henry S; da Silva, Alexandre J; Carter, Jacoby; White-Mclean, Jodi; Smith, Trevor
2013-01-01
Nonindigenous apple snails, Pomacea maculata (formerly Pomacea insularum), are currently spreading rapidly through the southeastern United States. This mollusk serves as an intermediate host of the rat lungworm parasite (Angiostrongylus cantonensis), which can cause eosinophilic meningitis in humans who consume infected mollusks. A PCR-based detection assay was used to test nonindigenous apple snails for the rat lungworm parasite in Louisiana, Texas, Mississippi, and Florida. Only apple snails obtained from the New Orleans, Louisiana, area tested positive for the parasite. These results provide the first evidence that Angiostrongylus cantonensis does occur in nonindigenous apple snails in the southeastern United States. Additionally, Angiostrongylus cantonensis was identified in the terrestrial species Achatina fulica in Miami, Florida, indicating that rat lungworm is now established in Florida as well as Louisiana. Although the study suggests that the rat lungworm is not widespread in the Gulf States region, the infected snail population could still pose a risk to human health and facilitate the spread of the parasite to new areas. PMID:23901374
Teem, John L.; Qvarnstrom, Yvonne; Bishop, Henry S.; da Silva, Alexandre J.; Carter, Jacoby; White-McLean, Jodi; Smith, Trevor
2013-01-01
Nonindigenous apple snails, Pomacea maculata (formerly Pomacea insularum), are currently spreading rapidly through the southeastern United States. This mollusk serves as an intermediate host of the rat lungworm parasite (Angiostrongylus cantonensis), which can cause eosinophilic meningitis in humans who consume infected mollusks. A PCR-based detection assay was used to test nonindigenous apple snails for the rat lungworm parasite in Louisiana, Texas, Mississippi, and Florida. Only apple snails obtained from the New Orleans, Louisiana, area tested positive for the parasite. These results provide the first evidence that Angiostrongylus cantonensis does occur in nonindigenous apple snails in the southeastern United States. Additionally, Angiostrongylus cantonensis was identified in the terrestrial species Achatina fulica in Miami, Florida, indicating that rat lungworm is now established in Florida as well as Louisiana. Although the study suggests that the rat lungworm is not widespread in the Gulf States region, the infected snail population could still pose a risk to human health and facilitate the spread of the parasite to new areas.
Arriola, Carmen S; Nelson, Deborah I; Deliberto, Thomas J; Blanton, Lenee; Kniss, Krista; Levine, Min Z; Trock, Susan C; Finelli, Lyn; Jhung, Michael A
2015-12-01
Newly emerged highly pathogenic avian influenza (HPAI) A H5 viruses have caused outbreaks among birds in the United States. These viruses differ genetically from HPAI H5 viruses that previously caused human illness, most notably in Asia and Africa. To assess the risk for animal-to-human HPAI H5 virus transmission in the United States, we determined the number of persons with self-reported exposure to infected birds, the number with an acute respiratory infection (ARI) during a 10-day postexposure period, and the number with ARI who tested positive for influenza by real-time reverse transcription PCR or serologic testing for each outbreak during December 15, 2014-March 31, 2015. During 60 outbreaks in 13 states, a total of 164 persons were exposed to infected birds. ARI developed in 5 of these persons within 10 days of exposure. H5 influenza virus infection was not identified in any persons with ARI, suggesting a low risk for animal-to-human HPAI H5 virus transmission.
Dosunmu, Adedoyin Owolabi; Akinbami, Akinsegun Abduljaleel; Ismail, Ayobami Kamal; Olaiya, Modupe Adebimpe; Uche, Ebele Ifeyinwa; Aile, Igbinoba Kingsley
2017-01-01
Blood transfusion practice emphasises safety, efficacy and appropriate use. These require cost-effective programme management. This study focused on the cost of screening for transfusion transmissible infections (TTI). This was a 1 year (2016) analysis of screening in a hospital-based transfusion centre. The cost of screening all blood donors by ELISA was compared to the cost of serial screening starting from rapid kit, taking into account, the estimated cost of blood bags prevented from discard after ELISA screening (attributable cost). The cost of voluntary donor drive plus cost of ELISA screening was compared with the present cost of screening. A total of 5591 donors were screened for HIV, hepatitis B and C using the rapid kit, 291 donors were deferred (5.2%). A total of 5300 units were further screened by ELISA. A total of 435 blood units (8.2%) were discarded due to TTI positivity. TTI positivity rate was 12.98%. Only 2.36% were voluntary donors and among these 9.1% were TTI positive. The attributable cost of serial screening was 55,653.5 USD while that of screening by ELISA only was 55,910 USD. The attributable cost of rapid screening for only hepatitis B and then ELISA was 53,313.9 USD taking into consideration that 187 blood units would be prevented from undue discard. This analysis demonstrated that with proper donor selection, rapid screening for hepatitis B virus only before ELISA screening is more cost-effective. This will also reduce the waiting time for donors and counselling if HIV positive.
Chagas disease screening among HIV-positive Latin American immigrants: an emerging problem.
Llenas-García, J; Hernando, A; Fiorante, S; Maseda, D; Matarranz, M; Salto, E; Rubio, R; Pulido, F
2012-08-01
Chagas disease (CD) is an emergent disease in Europe that can behave as an opportunistic infection in HIV positive patients. The objective of this study was to evaluate the implementation of a CD screening programme in an HIV unit. An immunochromatography (ICT) of Trypanosoma cruzi was performed as a screening tool in HIV-positive patients born in CD endemic countries. ELISA and IFAT were used to confirm the diagnosis. A total of 155 patients, 116 males and 38 females, were included. Mean age was 36.9 years (± 8.4) and mean length of stay in Spain at the screening was 7.1 years (± 4.7). T. cruzi ICT was positive in four cases (2.6%), being confirmed (by ELISA and IFAT) in three of those (1.9%). Factors associated with confirmed positive T.cruzi serology were: Bolivia origin (p=0.016), Bolivia or Argentina origin (p=0.002), Southern Cone origin (p=0.015), rural origin (p=0.023), previously living in an adobe-made (p=0.001) or thatch-roofed house (p<0.0001), having a previous CD test (p=0.015), previous knowledge about CD (p=0.019), about vector (p=0.009) or recorded seeing vectors at home (p=0.012). Units dealing with HIV patients from endemic areas of American trypanosomiasis should implement CD screening protocols. Interviews of patients coming from endemic areas should include CD epidemiological questions.
Létourneau, Daniel; Wang, An; Amin, Md Nurul; Pearce, Jim; McNiven, Andrea; Keller, Harald; Norrlinger, Bernhard; Jaffray, David A
2014-12-01
High-quality radiation therapy using highly conformal dose distributions and image-guided techniques requires optimum machine delivery performance. In this work, a monitoring system for multileaf collimator (MLC) performance, integrating semiautomated MLC quality control (QC) tests and statistical process control tools, was developed. The MLC performance monitoring system was used for almost a year on two commercially available MLC models. Control charts were used to establish MLC performance and assess test frequency required to achieve a given level of performance. MLC-related interlocks and servicing events were recorded during the monitoring period and were investigated as indicators of MLC performance variations. The QC test developed as part of the MLC performance monitoring system uses 2D megavoltage images (acquired using an electronic portal imaging device) of 23 fields to determine the location of the leaves with respect to the radiation isocenter. The precision of the MLC performance monitoring QC test and the MLC itself was assessed by detecting the MLC leaf positions on 127 megavoltage images of a static field. After initial calibration, the MLC performance monitoring QC test was performed 3-4 times/week over a period of 10-11 months to monitor positional accuracy of individual leaves for two different MLC models. Analysis of test results was performed using individuals control charts per leaf with control limits computed based on the measurements as well as two sets of specifications of ± 0.5 and ± 1 mm. Out-of-specification and out-of-control leaves were automatically flagged by the monitoring system and reviewed monthly by physicists. MLC-related interlocks reported by the linear accelerator and servicing events were recorded to help identify potential causes of nonrandom MLC leaf positioning variations. The precision of the MLC performance monitoring QC test and the MLC itself was within ± 0.22 mm for most MLC leaves and the majority of the apparent leaf motion was attributed to beam spot displacements between irradiations. The MLC QC test was performed 193 and 162 times over the monitoring period for the studied units and recalibration had to be repeated up to three times on one of these units. For both units, rate of MLC interlocks was moderately associated with MLC servicing events. The strongest association with the MLC performance was observed between the MLC servicing events and the total number of out-of-control leaves. The average elapsed time for which the number of out-of-specification or out-of-control leaves was within a given performance threshold was computed and used to assess adequacy of MLC test frequency. A MLC performance monitoring system has been developed and implemented to acquire high-quality QC data at high frequency. This is enabled by the relatively short acquisition time for the images and automatic image analysis. The monitoring system was also used to record and track the rate of MLC-related interlocks and servicing events. MLC performances for two commercially available MLC models have been assessed and the results support monthly test frequency for widely accepted ± 1 mm specifications. Higher QC test frequency is however required to maintain tighter specification and in-control behavior.
Liu, Z; Stout, J E; Boldin, M; Rugh, J; Diven, W F; Yu, V L
1998-01-01
One copper-silver ionization system was sequentially installed onto the hot-water recirculation lines of two hospital buildings colonized with Legionella pneumophila, serogroup 1. A third building with the same water supply and also colonized with Legionella served as a control. Four weeks after activation of the system, distal site positivity for Legionella in the first test building dropped to zero. After operating for 16 weeks, the system was disconnected and installed onto the second test building. Twelve weeks of disinfection reduced the distal site positivity for Legionella in the second test building to zero. Legionella recolonization did not occur in the first test building for 6-12 weeks and in the second test building for 8-12 weeks after inactivation of the system. The control building remained Legionella-positive throughout the experimental period. A significantly higher copper concentration was found in the biofilm taken from a sampling device than in that from water. This is likely to be the reason that the copper-silver ionization system had the residual effect of preventing early recolonization. Our study raises the possibility that one copper-silver unit could be rotated among several buildings to maintain a Legionella-free environment. Such an approach may be cost-effective for buildings housing individuals at low risk for contracting legionnaires' disease.
Cervical tuberculous adenitis: CT manifestations.
Reede, D L; Bergeron, R T
1985-03-01
Cervical tuberculous adenitis is being seen with increasing frequency in the United States; in the appropriate clinical setting it should be included in the differential diagnosis of an asymptomatic neck mass. Patients are typically young adults who are recent arrivals from Southeast Asia. A history of tuberculosis is not always elicited nor is the chest radiograph always abnormal. All of these patients have positive purified protein derivative tests unless they are anergic. The CT findings may lead to the diagnosis. Several CT patterns of nodal disease can be seen in tuberculous adenitis; some may mimic benign and neoplastic disease. The presence of a multiloculated or multichambered (conglomerate nodal) mass with central lucency and thick rims of enhancement and minimally effaced fascial planes is highly suggestive of tuberculous adenitis, especially if the patient has a strongly positive tuberculosis skin test.
Cervical tuberculous adenitis: CT manifestations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reede, D.L.; Bergeron, R.T.
1985-03-01
Cervical tuberculous adenitis is being seen with increasing frequency in the United States; in the appropriate clinical setting it should be included in the differential diagnosis of an asymptomatic neck mass. Patients are typically young adults who are recent arrivals from Southeast Asia. A history of tuberculosis is not always elicited nor is the chest radiograph always abnormal. All of these patients have positive purified protein derivative tests unless they are anergic. The CT findings may lead to the diagnosis. Several CT patterns of nodal disease can be seen in tuberculous adenitis; some may mimic benign and neoplastic disease. Themore » presence of a multiloculated or multichambered (conglomerate nodal) mass with central lucency and thick rims of enhancement and minimally effaced fascial planes is highly suggestive of tuberculous adenitis, especially if the patient has a strongly positive tuberculosis skin test.« less
Wang, Manli; Tao, Hongbing
2017-01-01
Objectives: Patient safety culture affects patient safety and the performance of hospitals. The Hospital Survey on Patient Safety Culture (HSOPSC) is generally used to assess the safety culture in hospitals and unit levels. However, only a few studies in China have measured surgical settings compared with other units in county hospitals using the HSOPSC. This study aims to assess the strengths and weaknesses of surgical departments compared with all other departments in county hospitals in China with HSOPSC. Design: This research is a cross-sectional study. Methods: In 2015, a Chinese translation of HSOPSC was administered to 1379 staff from sampled departments from 19 county hospitals in Xiaogan City (Hubei Province, China) using a simple random and cluster sampling method. Outcome Measures: The HSOPSC was completed by 1379 participants. The percent positive ratings (PPRs) of 12 dimensions (i.e., teamwork within units, organizational learning and continuous improvement, staffing, non-punitive response to errors, supervisor/ manager expectations and actions promoting patient safety, feedback and communication about errors, communication openness, hospital handoffs and transitions, teamwork across hospital units, hospital management support for patient safety, overall perception of safety, as well as frequency of events reported) and the positive proportion of outcome variables (patient safety grade and number of events reported) between surgical departments and other departments were compared with t-tests and X2 tests, respectively. A multiple regression analysis was conducted, with the outcome dimensions serving as dependent variables and basic characteristics and other dimensions serving as independent variables. Similarly, ordinal logistic regression was used to explore the influencing factors of two categorical outcomes. Results: A total of 56.49% of respondents were from surgical departments. The PPRs for “teamwork within units” and “organizational learning and continuous improvement” were ≥75%, which denoted strengths, and the PPRs for “staffing” and “non-punitive response to errors” were ≤50%, which denoted weaknesses in surgical units and other units. Three dimensions for surgical departments were weaker than those for other departments (p < 0.05). The staff from surgical units reported more events compared with the other units, but only a few respondents in surgical settings evaluated patient safety grade as good/excellent. Four dimensions influenced patient safety grade, and three dimensions influenced event reporting in surgical units. Conclusions: Strategies including recruiting workers, using the reporting system, and building a non-punitive culture should be adopted in the surgical units of county hospitals in China to improve safety culture. Supervisors should also prioritise patient safety. PMID:28954427
Carlfjord, S; Andersson, A; Nilsen, P; Bendtsen, P; Lindberg, M
2010-12-01
The transmission of research findings into routine care is a slow and unpredictable process. Important factors predicting receptivity for innovations within organizations have been identified, but there is a need for further research in this area. The aim of this study was to describe contextual factors and evaluate if organizational climate and implementation strategy influenced outcome, when a computer-based concept for lifestyle intervention was introduced in primary health care (PHC). The study was conducted using a prospective intervention design. The computer-based concept was implemented at six PHC units. Contextual factors in terms of size, leadership, organizational climate and political environment at the units included in the study were assessed before implementation. Organizational climate was measured using the Creative Climate Questionnaire (CCQ). Two different implementation strategies were used: one explicit strategy, based on Rogers' theories about the innovation-decision process, and one implicit strategy. After 6 months, implementation outcome in terms of the proportion of patients who had been referred to the test, was measured. The CCQ questionnaire response rates among staff ranged from 67% to 91% at the six units. Organizational climate differed substantially between the units. Managers scored higher on CCQ than staff at the same unit. A combination of high CCQ scores and explicit implementation strategy was associated with a positive implementation outcome. Organizational climate varies substantially between different PHC units. High CCQ scores in combination with an explicit implementation strategy predict a positive implementation outcome when a new working tool is introduced in PHC. © 2010 Blackwell Publishing Ltd.
Abrantes-Lemos, Clarice Pires; Nakhle, Maria Cristina; Damiao, Aderson Omar Mourao Cintra; Sipahi, Aytan Miranda; Carrilho, Flair José; Cancado, Eduardo Luiz R
2010-01-01
Sensitivity and specificity of anti-human tissue transglutaminase antibodies (anti-htTGA) seem to be superior to those of anti-tissue transglutaminase of guinea pig (anti-gptTGA) for screening patients with celiac disease (CD), but there are still controversies. The aim of this study was to evaluate the performance of two INOVA ELISA kits to detect IgA anti-htTGA and anti-gptTGA in patients with and without CD. The study groups were comprised of 49 anti-endomysial antibody (EMA)-positive untreated-CD, and 123 controls (EMA-negative treated CD, EMA-negative chronic diarrhea, autoimmune hepatitis, inflammatory bowel disease and healthy people). The agreement between the two ELISAs was statistically significant in all study groups and there was no significant difference between them (92.7% agreement; kappa = 0.70; kappa p = 0.001; McNemar p = 1). All patients with serum reactivity of more than 100 units had histologic diagnosis of CD. In seven of 10 patients with treated-CD who had control biopsies, villous atrophy was still present in four who tested positive by both kits. Two of three celiacs with histologic remission tested positive for both anti-tTGA. the anti-gptTGA and anti-htTGA determination were equally efficient in identifying patients with untreated-CD with high titers of EMA. Whatever the anti-tTGA ELISA used, the reactivity above 100 units was always related to active CD diagnosed by histologic alterations in intestinal biopsies. The anti-tTGA reactivity by both kits was not only similar in determining histologic activity in the follow-up of CD after a gluten free diet, but also in identifying positive sera from the control groups, regardless if CD has been confirmed by duodenal biopsies.
Transfusion-Transmitted Dengue and Associated Clinical Symptoms During the 2012 Epidemic in Brazil
Sabino, Ester C.; Loureiro, Paula; Lopes, Maria Esther; Capuani, Ligia; McClure, Christopher; Chowdhury, Dhuly; Di-Lorenzo-Oliveira, Claudia; Oliveira, Lea C.; Linnen, Jeffrey M.; Lee, Tzong-Hae; Gonçalez, Thelma; Brambilla, Donald; Kleinman, Steve; Busch, Michael P.; Custer, Brian
2016-01-01
Background. A linked donor-recipient study was conducted during epidemics in 2 cities in Brazil to investigate transfusion-transmitted (TT) dengue virus (DENV) by DENV RNA–positive donations. Methods. During February–June 2012, samples were collected from donors and recipients and retrospectively tested for DENV RNA by transcription-mediated amplification. Recipient chart review, using a case (DENV positive)–control (DENV negative and not known to be exposed) design, was conducted to assess symptoms. Results. Of 39 134 recruited blood donors, DENV-4 viremia was confirmed in 0.51% of donations from subjects in Rio de Janeiro and 0.80% of subjects in Recife. Overall, 42 DENV RNA–positive units were transfused into 35 recipients. Of these, 16 RNA-positive units transfused into 16 susceptible recipients were identified as informative: 5 cases were considered probable TT cases, 1 possible TT case, and 10 nontransmissions. The TT rate was 37.5% (95% confidence interval [CI], 15.2%–64.6%), significantly higher than the viremia rate of 0.93% (95% CI, .11%–3.34%) in nonexposed recipients (P < .0001). Chart review did not find significant differences between cases and controls in symptoms or mortality. Conclusions. During a large epidemic of DENV-4 infection in Brazil, >0.5% of donations were RNA positive, and approximately one third of components resulted in TT. However, no significant clinical differences were evident between RNA-positive and RNA-negative recipients. PMID:26908780
Operational Evaluation of VEGGIE Food Production System in the Habitat Demonstration Unit
NASA Technical Reports Server (NTRS)
Stutte, Gary W.; Newsham, Gerard; Morrow, Robert M.; Wheeler, Raymond M.
2011-01-01
The 2010 Desert Research and Technology Studies (DRATS) of the VEGGIE Food Production System in the Habitat Demonstration Unit (HDU) Pressurized Excursion Module (PEM) was the first operational evaluation of salad crop production technology in a NASA analog test. A systematic evaluation of rooting media and nutrient delivery systems were evaluated for three lettuce cultivars that have shown promise as candidates for a surface based food production system. The VEGGIE nutrient delivery system worked well, was able to be maintained by multiple operators with a minimum of training, and supported excellent lettuce growth for the duration of the test. A Hazard Analysis and Critical Control Point (HACCP) evaluation was performed using ProSan(tm) as sanitation agent prior to consumption was approved, and the crew was allowed to consume the lettuce grown using the VEGGIE light cap and gravity based nutrient delivery system at the completion of the 14-day DRAT field test. The DRAT field test validated the crew operations; Growth of all lettuce cultivars was excellent. The operational DRAT field testing in the HDU identified light quality issues related to morphology and pigment development that will need to be addressed through additional testing. Feedback from the crew, ground support personnel, and human factors leads was uniformly positive on the psychological value of having the crop production system in the excursion module. A number of areas have been identified for future work, to minimize the "footprint" of the Food Production system through creative use of unused wall and floor space in the unit.
Operation Evaluation of the VEGGIE Food Production System in the Habitat Demonstration Unit
NASA Technical Reports Server (NTRS)
Stutte, Gary W.; Newsham, Gerard; Morrow, Robert M.; Wheeler, Raymond M.
2011-01-01
The 2010 Desert Research and Technology Studies (DRATS) of the VEGGIE Food Production System in the Habitat Demonstration Unit (HDU) Pressurized Excursion Module (PEM) was the first operational evaluation of salad crop production technology in a NASA analog test. A systematic evaluation of rooting media and nutrient delivery systems were evaluated for three lettuce cultivars that have shown promise as candidates for a surface based food production system. The VEGGIE nutrient delivery system worked well, was able to be maintained by multiple operators with a minimum of training, and supported excellent lettuce growth for the duration of the test. A Hazard Analysis and Critical Control Point (HACCP) evaluation was performed using ProSantm as sanitation agent prior to consumption was approved, and the crew was allowed to consume the lettuce grown using the VEGGIE light cap and gravity based nutrient delivery system at the completion of the 14-day DRAT field test. The DRAT field test validated the crew operations; Growth of all lettuce cultivars was excellent. The operational DRAT field testing in the HDU identified light quality issues related to morphology and pigment development that will need to be addressed through additional testing. Feedback from the crew, ground support personnel, and human factors leads was uniformly positive on the psychological value of having the crop production system in the excursion module. A number of areas have been identified for future work, to minimize the "footprint" of the Food Production system through creative use of unused wall and floor space in the unit.
Goswami, Neela D.; Bissette, Deborah J.; Turner, Debra S.; Baker, Ann V.; Gadkowski, L. Beth; Naggie, Susanna; Erlandson, Kirby; Chen, Luke; Lalani, Tahaniyat; Cox, Gary M.; Stout, Jason E.
2010-01-01
Abstract Knowing one's HIV status is particularly important in the setting of recent tuberculosis (TB) exposure. Blood tests for assessment of tuberculosis infection, such as the QuantiFERON Gold in-tube test (QFT; Cellestis Limited, Carnegie, Victoria, Australia), offer the possibility of simultaneous screening for TB and HIV with a single blood draw. We performed a cross-sectional analysis of all contacts to a highly infectious TB case in a large meatpacking factory. Twenty-two percent were foreign-born and 73% were black. Contacts were tested with both tuberculin skin testing (TST) and QFT. HIV testing was offered on an opt-out basis. Persons with TST ≥10 mm, positive QFT, and/or positive HIV test were offered latent TB treatment. Three hundred twenty-six contacts were screened: TST results were available for 266 people and an additional 24 reported a prior positive TST for a total of 290 persons with any TST result (89.0%). Adequate QFT specimens were obtained for 312 (95.7%) of persons. Thirty-two persons had QFT results but did not return for TST reading. Twenty-two percent met the criteria for latent TB infection. Eighty–eight percent accepted HIV testing. Two (0.7%) were HIV seropositive; both individuals were already aware of their HIV status, but one had stopped care a year previously. None of the HIV-seropositive persons had latent TB, but all were offered latent TB treatment per standard guidelines. This demonstrates that opt-out HIV testing combined with QFT in a large TB contact investigation was feasible and useful. HIV testing was also widely accepted. Pairing QFT with opt-out HIV testing should be strongly considered when possible. PMID:20731612
Inductive Linear-Position Sensor/Limit-Sensor Units
NASA Technical Reports Server (NTRS)
Alhom, Dean; Howard, David; Smith, Dennis; Dutton, Kenneth
2007-01-01
A new sensor provides an absolute position measurement. A schematic view of a motorized linear-translation stage that contains, at each end, an electronic unit that functions as both (1) a non-contact sensor that measures the absolute position of the stage and (2) a non-contact equivalent of a limit switch that is tripped when the stage reaches the nominal limit position. The need for such an absolute linear position-sensor/limit-sensor unit arises in the case of a linear-translation stage that is part of a larger system in which the actual stopping position of the stage (relative to the nominal limit position) must be known. Because inertia inevitably causes the stage to run somewhat past the nominal limit position, tripping of a standard limit switch or other limit sensor does not provide the required indication of the actual stopping position. This innovative sensor unit operates on an electromagnetic-induction principle similar to that of linear variable differential transformers (LVDTs)
Tests on ticks from wild birds collected in the eastern United States for rickettsiae and viruses
Clifford, C.M.; Sonenshine, D.E.; Atwood, E.L.; Robbins, C.S.; Hughes, L.E.
1969-01-01
Results of tests for rickettsiae and viruses on 4,266 ticks taken from more than 10,000 birds, comprising 150 species, in the eastern United States indicated the presence of two agents: Rickettsia rickettsii and an agent of the typhus group. Infection with R. rickettsii was indicated in 24 pools of Haemaphysalis leporispalustris, five pools of Ixodes dentatus, one pool of Ixodes brunneus, and two pools that contained both I. dentatus and H. leporispalustris. The pools positive for R. rickettsii were from a variety of locations in the eastern U. S. The typhus-group agent was demonstrated only once, in a single pool of H. leporispalustris taken at Kent Point, Maryland. A strain of R. rickettsii was isolated from a pool of 21 larval H. leporispalustris collected at Ocean City, Maryland. This agent possessed several characteristics of other strains of low virulence isolated previously in this region by various authors.
House, J Daniel
2009-04-01
Recent mathematics assessment findings indicate that Native American students tend to score below students of the ethnic majority. Findings suggest that students' beliefs about mathematics are significantly related to achievement outcomes. This study examined relations between self-beliefs and mathematics achievement for a national sample of 130 Grade 8 Native American students from the Trends in International Mathematics and Science Study (TIMSS) 2003 United States sample of (M age = 14.2 yr., SD = 0.5). Multiple regression indicated several significant relations of mathematics beliefs with achievement and accounted for 26.7% of the variance in test scores. Students who earned high test scores tended to hold more positive beliefs about their ability to learn mathematics quickly, while students who earned low scores expressed negative beliefs about their ability to learn new mathematics topics.
Transformational leadership training programme for charge nurses.
Duygulu, Sergul; Kublay, Gulumser
2011-03-01
This paper is a report of an evaluation of the effects of a transformational leadership training programme on Unit Charge Nurses' leadership practices. Current healthcare regulations in the European Union and accreditation efforts of hospitals for their services mandate transformation in healthcare services in Turkey. Therefore, the transformational leadership role of nurse managers is vital in determining and achieving long-term goals in this process. The sample consisted of 30 Unit Charge Nurses with a baccalaureate degree and 151 observers at two university hospitals in Turkey. Data were collected using the Leadership Practices Inventory-Self and Observer (applied four times during a 14-month study process from December 2005 to January 2007). The transformational leadership training programme had theoretical (14 hours) and individual study (14 hours) in five sections. Means, standard deviations and percentages, repeated measure tests and two-way factor analysis were used for analysis. According the Leadership Practices Inventory-Self and Observer ratings, leadership practices increased statistically significantly with the implementation of the programme. There were no significant differences between groups in age, length of time in current job and current position. The Unit Charge Nurses Leadership Practices Inventory self-ratings were significantly higher than those of the observers. There is a need to develop similar programmes to improve the leadership skills of Unit Charge Nurses, and to make it mandatory for nurses assigned to positions of Unit Charge Nurse to attend this kind of leadership programme. © 2010 Blackwell Publishing Ltd.
Winer, Rachel L; Gonzales, Angela A; Noonan, Carolyn J; Cherne, Stephen L; Buchwald, Dedra S
2016-10-01
We evaluated the feasibility and acceptability of self-sampling for human papillomavirus (HPV) testing and calculated the prevalence of and risk factors for high-risk (hr) HPV infections in a community-based sample of American Indian women. To this end, we recruited 329 Hopi women aged 21-65 years to self-collect vaginal samples for hrHPV testing. Samples were tested by polymerase chain reaction for 14 hrHPV genotypes. We used Chi square tests to identify correlates of preference for clinician Pap testing versus HPV self-sampling, and age-adjusted Poisson regression to evaluate correlates of hrHPV prevalence. We found that satisfaction with HPV self-sampling was high, with 96 % of women reporting that the sample was easy to collect and 87 % reporting no discomfort. The majority (62 %) indicated that they preferred HPV self-sampling to receiving a Pap test from a clinician. Preference for Pap testing over HPV self-sampling was positively associated with adherence to Pap screening and employment outside the home. All samples evaluated were satisfactory for HPV testing, and 22 % were positive for hrHPV. HrHPV prevalence peaked in the late 20 s and declined with increasing age. HrHPV positivity was inversely associated with having children living the household. In conclusion, HPV self-sampling is feasible and acceptable to Hopi women, and could be effective in increasing rates of cervical cancer screening in Hopi communities. HrHPV prevalence was similar to estimates in the general United States population.
System for fracturing an underground geologic formation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mace, Jonathan L.; Tappan, Bryce C.; Seitz, Gerald J.
2017-03-14
An explosive system for fracturing an underground geologic formation adjacent to a wellbore can comprise a plurality of explosive units comprising an explosive material contained within the casing, and detonation control modules electrically coupled to the plurality of explosive units and configured to cause a power pulse to be transmitted to at least one detonator of at least one of the plurality of explosive units for detonation of the explosive material. The explosive units are configured to be positioned within a wellbore in spaced apart positions relative to one another along a string with the detonation control modules positioned adjacentmore » to the plurality of explosive units in the wellbore, such that the axial positions of the explosive units relative to the wellbore are at least partially based on geologic properties of the geologic formation adjacent the wellbore.« less
Analysis of gunshot residue test results in 112 suicides.
Reed, G E; McGuire, P J; Boehm, A
1990-01-01
The results of gunshot residue (GSR) tests in 112 suicide cases investigated by the U.S. Army Criminal Investigation Command over a ten-year period are described. Only suicide cases in which there was certainty that the victim fired a weapon were examined in an effort to reduce ambiguous results. Previous case work research by Rudzitis indicated that positive GSR test results were encountered in suicides 62% of the time using various combinations of neutron activation analysis (NAA) and atomic absorption spectrophotometry (AAS). Threshold values of 0.2-micrograms antimony and 0.3-micrograms barium (0.2-micrograms antimony and 0.5-micrograms barium after 1985) used by the U.S. Army Criminal Investigation Laboratory resulted in positive GSR results in suicide cases 38% of the time. The effects of time, location of body, handling of the body, weapon type, caliber, and condition of the hands on GSR results are examined. Case studies involving suicides by unit armorers are discussed.
The relative utility of the autologous control and the antiglobulin test phase of the crossmatch.
Perkins, J T; Arruza, M; Fong, K; Sosler, S D; Saporito, C
1990-01-01
A retrospective study of pretransfusion testing records compared the utility of the antiglobulin test (AGT) phase of the crossmatch and the autologous control (autocontrol) for detecting clinically significant alloimmunization to red cells (RBCs). Of 110,780 consecutive crossmatches, 141 were positive after a negative antibody screening test; only 4 of these were due to alloantibodies of potential clinical significance, for a predictive value of a positive AGT crossmatch, after a negative antibody screen, of 2.8 percent (4/141). The frequency of potentially shortened RBC survival was 1 in 27,685 units crossmatched. During a similar period, 56,090 autocontrols were performed with the antibody screen. The autocontrol was positive on 902 samples in which the antibody screen was negative. Antibody identification performed in 684 cases generally yielded only cold or warm autoagglutinins. In 96 cases, some form of alloantibody was detected, but only 25 had potential clinical significance by our criteria. Eight of these alloantibodies had concurrently caused in vivo sensitization of RBCs and were classified as delayed hemolytic transfusion reactions. The predictive value of the autocontrol, calculated as the number of significant alloantibodies detected in autocontrol-positive, antibody-screen-negative samples, was 3.6 percent (25/684). Inspection of these cases revealed 11 in which shortened RBC survival might have resulted if the serologic abnormality had not been detected. Thus, the autocontrol had a slightly greater yield of clinically significant findings than the AGT crossmatch.(ABSTRACT TRUNCATED AT 250 WORDS)
Laws, Holly; Mazure, Carolyn M; McKee, Sherry A; Park, Crystal L; Hoff, Rani
2016-09-01
Few studies have examined the impact of military sexual trauma (MST) on social functioning during deployment. Yet consideration of unit relationships during deployment may be important, given that military unit cohesion and support can provide protective effects against the stress of combat, and reduce the likelihood of developing posttraumatic stress disorder. Although prior research has posited that depleted social resources are one pathway through which MST is associated with posttraumatic stress symptoms (PTSS), no studies have statistically tested this theory. This study examined the association of MST and PTSS and evaluated the potential mediating role of decreased unit relationship quality. Mediational analyses were conducted on a sample of veterans following discharge from military service (N = 818; 328 women, 490 men). Women were significantly more likely to experience MST than men. As hypothesized, experiences of MST during deployment were associated with higher PTSS. MST experiences were associated with less trust in and support from one's military unit, which partially mediated the association between MST and PTSS. The indirect effect of MST on PTSS through lower unit relationship quality accounted for 20.4% of the total effect of MST on PTSS. While the retrospective study design precludes tests of causality, mediational findings provided statistical evidence that lower unit relationship quality partially explains the association between MST and PTSS. This finding is consistent with interpersonal theories of trauma response suggesting that the deleterious effects of MST may be in part due to its erosion of social resources during deployment. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
2014-10-01
CAPE CANAVERAL, Fla. – The United Launch Alliance Delta IV Heavy rocket for Exploration Flight Test-1 is being lifted to the vertical position at the pad at Space Launch Complex 37 at Cape Canaveral Air Force Station in Florida. The Delta IV Heavy is being readied to launch Orion on its first flight test. During its first flight test, Orion will travel farther into space than any human spacecraft has gone in more than 40 years. The data gathered during the flight will influence design decisions, validate existing computer models and innovative new approaches to space systems development, as well as reduce overall mission risks and costs for later Orion flights. Liftoff of Orion on the first flight test is planned for December 2014. Photo credit: NASA/Daniel Casper
EFT-1 Delta IV Heavy lift to vertical
2014-10-01
This close-up view shows the United Launch Alliance Delta IV Heavy rocket for Exploration Flight Test-1 being raised into the vertical position at the pad at Space Launch Complex 37 at Cape Canaveral Air Force Station in Florida. The Delta IV Heavy is being readied to launch Orion on its first flight test. During its first flight test, Orion will travel farther into space than any human spacecraft has gone in more than 40 years. The data gathered during the flight will influence design decisions, validate existing computer models and innovative new approaches to space systems development, as well as reduce overall mission risks and costs for later Orion flights. Liftoff of Orion on the first flight test is planned for December 2014.
EFT-1 Delta IV Heavy lift to vertical
2014-10-01
The United Launch Alliance Delta IV Heavy rocket for Exploration Flight Test-1 is lifted to the vertical position in the mobile service tower on the pad at Space Launch Complex 37 at Cape Canaveral Air Force Station in Florida. The Delta IV Heavy is being readied to launch Orion on its first flight test. During its first flight test, Orion will travel farther into space than any human spacecraft has gone in more than 40 years. The data gathered during the flight will influence design decisions, validate existing computer models and innovative new approaches to space systems development, as well as reduce overall mission risks and costs for later Orion flights. Liftoff of Orion on the first flight test is planned for December 2014.
2014-10-01
CAPE CANAVERAL, Fla. – The United Launch Alliance Delta IV Heavy rocket for Exploration Flight Test-1 is being lifted to the vertical position at the pad at Space Launch Complex 37 at Cape Canaveral Air Force Station in Florida. The Delta IV Heavy is being readied to launch Orion on its first flight test. During its first flight test, Orion will travel farther into space than any human spacecraft has gone in more than 40 years. The data gathered during the flight will influence design decisions, validate existing computer models and innovative new approaches to space systems development, as well as reduce overall mission risks and costs for later Orion flights. Liftoff of Orion on the first flight test is planned for December 2014. Photo credit: NASA/Daniel Casper
EFT-1 Delta IV Heavy lift to vertical
2014-10-01
The United Launch Alliance Delta IV Heavy rocket for Exploration Flight Test-1 is being lifted to the vertical position at the pad at Space Launch Complex 37 at Cape Canaveral Air Force Station in Florida. The Delta IV Heavy is being readied to launch Orion on its first flight test. During its first flight test, Orion will travel farther into space than any human spacecraft has gone in more than 40 years. The data gathered during the flight will influence design decisions, validate existing computer models and innovative new approaches to space systems development, as well as reduce overall mission risks and costs for later Orion flights. Liftoff of Orion on the first flight test is planned for December 2014.
Viable Mycobacterium avium ssp. paratuberculosis isolated from calf milk replacer.
Grant, Irene R; Foddai, Antonio C G; Tarrant, James C; Kunkel, Brenna; Hartmann, Faye A; McGuirk, Sheila; Hansen, Chungyi; Talaat, Adel M; Collins, Michael T
2017-12-01
When advising farmers on how to control Johne's disease in an infected herd, one of the main recommendations is to avoid feeding waste milk to calves and instead feed calf milk replacer (CMR). This advice is based on the assumption that CMR is free of viable Mycobacterium avium ssp. paratuberculosis (MAP) cells, an assumption that has not previously been challenged. We tested commercial CMR products (n = 83) obtained from dairy farms around the United States by the peptide-mediated magnetic separation (PMS)-phage assay, PMS followed by liquid culture (PMS-culture), and direct IS900 quantitative PCR (qPCR). Conventional microbiological analyses for total mesophilic bacterial counts, coliforms, Salmonella, coagulase-negative staphylococci, streptococci, nonhemolytic Corynebacterium spp., and Bacillus spp. were also performed to assess the overall microbiological quality of the CMR. Twenty-six (31.3%) of the 83 CMR samples showed evidence of the presence of MAP. Seventeen (20.5%) tested positive for viable MAP by the PMS-phage assay, with plaque counts ranging from 6 to 1,212 pfu/50 mL of reconstituted CMR (average 248.5 pfu/50 mL). Twelve (14.5%) CMR samples tested positive for viable MAP by PMS-culture; isolates from all 12 of these samples were subsequently confirmed by whole-genome sequencing to be different cattle strains of MAP. Seven (8.4%) CMR samples tested positive for MAP DNA by IS900 qPCR. Four CMR samples tested positive by both PMS-based tests and 5 CMR samples tested positive by IS900 qPCR plus one or other of the PMS-based tests, but only one CMR sample tested positive by all 3 MAP detection tests applied. All conventional microbiology results were within current standards for whole milk powders. A significant association existed between higher total bacterial counts and presence of viable MAP indicated by either of the PMS-based assays. This represents the first published report of the isolation of viable MAP from CMR. Our findings raise concerns about the potential ability of MAP to survive manufacture of dried milk-based products. The Authors. Published by the Federation of Animal Science Societies and Elsevier Inc. on behalf of the American Dairy Science Association®. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/).
Jacobson, Gary P; McCaslin, Devin L; Piker, Erin G; Gruenwald, Jill; Grantham, Sarah; Tegel, Lauren
2011-01-01
The objective of this study was to assess the sensitivity, specificity, and positive and negative predictive value of the Romberg Test of Standing Balance on Firm and Compliant Support Surfaces (RTSBFCSS) for the identification of patients with vestibular system impairments affecting the horizontal semicircular canal, saccule, and/or inferior and superior vestibular nerves. The RTSBFCSS was developed for the National Health and Nutrition Examination Survey (NHANES) and was used recently to estimate the numbers of individuals aged 40 yr or older with vestibular system impairments among the general population of the United States. A retrospective analysis of the medical records of 103 consecutive patients aged 40 yr or older (mean age 59 ± 12 yr, 71 females) who had undergone vestibular assessment at the Balance Disorders Clinic at the Vanderbilt University School of Medicine. Patients with complete electro- or videonystagmography testing, cervical vestibular evoked myogenic potential (cVEMP) testing, and the RTSBFCSS screening test were included in the analysis. A series of 2 × 2 tables were created that represented the number of "true positives," "true negatives," "false positives," and "false negatives" of the RTSBFCSS under conditions where the caloric test was abnormal and then separately where the cVEMP test was abnormal. The data were analyzed in a manner such that sensitivity, specificity, and both positive and negative predictive value of the RTSBFCSS could be calculated. When the caloric test was used as the criterion standard and the subject selection criteria in the NHANES study were used (i.e., subjects who were able to maintain postural stability for trials 1-3 of the RTSBFCSS; N = 45), the sensitivity and specificity of the RTSBFCSS to impairment of the horizontal semicircular canal or superior vestibular nerve were 55% and 64%, respectively, yielding positive and negative predictive values of 55% and 64%, respectively. When all patients aged 40 yr or older were evaluated (N = 103), the sensitivity and specificity were 61% and 58%, respectively, yielding positive and negative predictive values of 39% and 78%, respectively. Using the cVEMP test as the criterion standard for the detection of impairment affecting the saccule and/or inferior vestibular nerve did not improve the performance criteria of the NHANES screening measure. The RTSBFCSS should not be used as a screening measure for vestibular impairment.
Cao, Dong-Yuan; Pickar, Joel G.
2014-01-01
We determined whether spinal manipulation could prevent and/or reverse the decrease and increase in paraspinal muscle spindle responsiveness caused respectively by lengthening and shortening histories of the lumbar muscles. Single unit spindle activity from multifidus and longissimus muscles was recorded in the L6 dorsal root in anesthetized cats. Muscle history was created and spinal manipulation delivered (thrust amplitude: 1.0mm, duration: 100ms) using a feedback-controlled motor attached to the L6 spinous process. Muscle spindle discharge to a fixed vertebral position (static test) and to vertebral movement (dynamic test) was evaluated following the lengthening and shortening histories. For the static test, changes in muscle spindle responsiveness were significantly less when spinal manipulation followed muscle history (p<0.01), but not when spinal manipulation preceded it (p>0.05). For the dynamic test, spinal manipulation did not significantly affect the history-induced change in muscle spindle responsiveness. Spinal manipulation may partially reverse the effects of muscle history on muscle spindle signaling of vertebral position. PMID:24932019
TECRA Unique test for rapid detection of Salmonella in food: collaborative study.
Hughes, D; Dailianis, A E; Hill, L; McIntyre, D A; Anderson, A
2001-01-01
The TECRA Unique Salmonella test uses the principle of immunoenrichment to allow rapid detection of Salmonellae in food. A collaborative study was conducted to compare the TECRA Salmonella Unique test with the reference culture method given in the U.S. Food and Drug Administration's Bacteriological Analytical Manual. Three food types (milk powder, pepper, and soy flour) were analyzed in Australia and 2 food types (milk chocolate and dried egg) were analyzed in the United States. Forty-one collaborators participated in the study. For each of the 5 foods at each of the 3 levels, a comparison showed no significant differences (p > or = 0.05) in the proportion of positive test samples for Unique and that for the reference method using the Chi-square test for independence with continuity correction.
Weinfurter, P; Blumberg, H M; Goldbaum, G; Royce, R; Pang, J; Tapia, J; Bethel, J; Mazurek, G H; Toney, S; Albalak, R
2011-08-01
Persons in whom targeted testing for latent tuberculosis infection (LTBI) is recommended in Seattle, Washington; Atlanta, Georgia; and central North Carolina, United States. To compare the performance of an interferon-gamma release assay (QuantiFERON®-TB Gold In-Tube [QFT-GIT]) with the tuberculin skin test (TST) among foreign-born, homeless, human immunodeficiency virus (HIV) infected and substance abuse persons tested for LTBI. A cross-sectional study requiring participants to have a blood test, a TST and data collected. Of 1653 persons, 19.5% were TST-positive and 14.0% were QFT-GIT-positive. Overall concordance was moderate (kappa 0.53; 95%CI 0.47-0.58). Compared to concordant positive results, TST+/QFT-GIT- discordance was associated with HIV infection and sex, while TST-/QFT-GIT+ discordance was associated with HIV and inversely associated with foreign birth. Compared to concordant negative results, TST-/QFT-GIT+ discordance was associated with foreign birth and age ≥50 years, while TST+/QFT-GIT-discordance was associated with foreign birth, age 30-49 years, being Black and inversely associated with HIV. HIV infection was significantly associated with indeterminate QFT-GIT results. QFT-GIT may be an improvement over the TST for diagnosing LTBI in foreign-born and older persons, and may be as useful as the TST in HIV-infected persons. The sensitivity of both tests may be low in HIV-infected persons.
Mullan, Helen; Richards, Jane; Lee, John
2017-12-01
The British Association for Sexual Health and HIV (BASHH) revised United Kingdom national guideline for the management of gonorrhoea in adults, 2011, identified five auditable outcome measures, namely, that all patients should receive first-line treatment, be screened or treated for chlamydial infection, have a test of cure (TOC), be offered written information and have partner notification carried out. The UK National Guideline for Gonorrhoea Testing, Clinical Effectiveness Group, BASHH, 2012, recommended in addition that all reactive nucleic acid amplification tests (NAATs) from pharynx and rectum should be confirmed by supplementary testing, using a second NAAT which detects a different nucleic acid target, all those with a positive NAAT for gonorrhoea should have culture and antimicrobial susceptibility testing and that TOC should be done by two weeks. Staff, associate specialist and specialty doctors performed a national audit against these standards. Data from 3233 cases were submitted; 8% of cases of gonorrhoea diagnosed in England, Scotland and Wales over this period. We found that 83% patients received first-line treatment with a reason for not doing so provided for 11%. TOC was documented for 62% and written information was offered to 41%. Results about supplementary testing were inconsistent. The results for the other outcomes were satisfactory.
Spiller, Michael W; Broz, Dita; Wejnert, Cyprian; Nerlander, Lina; Paz-Bailey, Gabriela
2015-03-20
In the United States, an estimated 7% of new diagnoses of human immunodeficiency virus (HIV) infection in 2012 were attributed to injection drug use, and an additional 3% to male-to-male sexual contact and injection drug use. To monitor HIV prevalence and behaviors associated with HIV risk and prevention among persons who inject drugs (PWID), CDC's National HIV Behavioral Surveillance (NHBS) system conducts interviews and HIV testing in selected cities. This report summarizes HIV prevalence and behaviors among PWID interviewed and tested in 20 cities in 2012. Of the 10,002 PWID tested, 11% had a positive HIV test result. Among 9,425 PWID included in the behavioral analysis, 30% receptively shared syringes, 70% had vaginal sex without a condom, 25% had heterosexual anal sex without a condom, and 5% of males had male-to-male sexual contact without a condom in the previous 12 months. Fifty-one percent of PWID included in the behavioral analysis had been tested for HIV, 25% participated in an HIV behavioral intervention, and 39% participated in substance abuse treatment in the previous 12 months. Additional efforts are needed to reduce risk behaviors and increase access to HIV testing, drug treatment, and other HIV prevention programs to further reduce HIV infections among PWID.
The cost of blood collection in Greece: an economic analysis.
Fragoulakis, Vassilis; Stamoulis, Kostas; Grouzi, Elisabeth; Maniadakis, Nikolaos
2014-07-01
The goal of this study was to estimate the cost of production of 1 unit of blood from a National Health Service perspective in Greece. In agreement with guidelines, the cost of blood production in this study accounted only for the resources expended for collection, processing, laboratory testing, and storage. Hence, the costs associated with donor recruitment, pretransfusion preparation, transfusion administration, follow-up management of adverse events, and other long-term relevant costs were not taken into consideration. The indirect cost of blood donations for donors (productivity loss) was also considered. A questionnaire was used to collect data regarding personnel time, annual blood quantities collected, percentage of wastage, utilization of consumables, institutional overhead, information technology expenditure, medical equipment utilized, nuclear acid tests, and other factors. Data gathered by 53 hospitals across the country were assessed. A model was constructed with economic data collected by the National School of Public Health and the Ministry of Health. All data refer to the year 2013. The weighted mean direct cost of producing 1 unit of blood was estimated at €131.49 (SD, €22.12; minimum/maximum, €94.96-€239.20). The mean total indirect cost was estimated at €34 per unit of blood. The cost distribution was positively skewed (skewness, 1.642 [0.327]). The major cost component was the cost of personnel, accounting for 32.5% of total costs, and the average of blood unit wastage was estimated at 4.90%. There were no differences between the cost of producing 1 unit of blood in Athens compared with the rest of the country (Mann-Whitney test, P = 0.341). This study suggests that the cost of producing 1 unit of blood is not insignificant. These figures need to be complemented with those concerning the cost of transfusion to have a complete picture of producing and using 1 unit of blood locally. Copyright © 2014 Elsevier HS Journals, Inc. All rights reserved.
Tuberculosis transmission by Mycobacterium bovis in a mixed cattle and goat herd.
Zanardi, Giorgio; Boniotti, Maria Beatrice; Gaffuri, Alessandra; Casto, Barbara; Zanoni, Mariagrazia; Pacciarini, Maria Lodovica
2013-10-01
A tuberculosis (TB) outbreak caused by Mycobacterium bovis occurred in a mixed herd of three cattle and eighteen goats in Northern Italy in 2005. All the cattle were removed, as opposed to the co-existing goats, who remained in the farm and were not subsequently tested by the official intradermal tuberculin test. At the beginning of May 2006, a 7-day old calf was introduced into the herd from an officially TB-free (OTF) farm. On October 2006, tuberculous lesions were detected at the slaughterhouse in the same animal. The following epidemiological investigation on the herd highlighted a clinical suspicion of TB in one goat out of 35, and visible lesions were found at necropsy in the respiratory and intestinal tracts. Bacteriological culture and molecular tests confirmed the presence of M. bovis in both animals. Spoligotyping and Mycobacterial Interspersed Repetitive Units - Variable Number of Tandem Repeats (MIRU-VNTR) showed the same genomic profile of the previous breakdown occurred in 2005. Since this profile has never been described in Italy, these findings suggest the probable transmission of TB within the farm among cattle and goats. The remaining 34 goats were also tested by single intradermal cervical comparative tuberculin (SICCT) test, Interferon (IFN)-γ assay and ELISA for antibody to M. bovis. The SICCT test and the IFN-γ showed a good concordance with 20 and 19 positive reactors, respectively. By ELISA we found 12Ab-positive animals, seven of which had not been detected by the tests for cell-mediated immunity. Finally, 15 goats were found positive for gross lesions at necropsy. The in vivo tests revealed a total of 27 positive animals out of 35, which highlights the usefulness of the serology in parallel with SICCT and IFN-γ when an advanced stage of infection is suspected. Moreover, our results confirm the necessity for adopting the official tuberculin test on goats co-existing with cattle. Copyright © 2013. Published by Elsevier India Pvt Ltd.
Low, Ariana; Kok, Si Ling; Khong, Yuetmei; Chan, Sui Yung; Gokhale, Rajeev
2015-11-01
No standard time or pharmacopoeia disintegration test method for orodispersible films (ODFs) exists. The USP disintegration test for tablets and capsules poses significant challenges for end-point determination when used for ODFs. We tested a newly developed disintegration test unit (DTU) against the USP disintegration test. The DTU is an accessory to the USP disintegration apparatus. It holds the ODF in a horizontal position, allowing top-view of the ODF during testing. A Gauge R&R study was conducted to assign relative contributions of the total variability from the operator, sample or the experimental set-up. Precision was compared using commercial ODF products in different media. Agreement between the two measurement methods was analysed. The DTU showed improved repeatability and reproducibility compared to the USP disintegration system with tighter standard deviations regardless of operator or medium. There is good agreement between the two methods, with the USP disintegration test giving generally longer disintegration times possibly due to difficulty in end-point determination. The DTU provided clear end-point determination and is suitable for quality control of ODFs during product developmental stage or manufacturing. This may facilitate the development of a standardized methodology for disintegration time determination of ODFs. © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association J Pharm Sci 104:3893-3903, 2015. Copyright © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association.
Authentic leadership and nurses' voice behaviour and perceptions of care quality.
Wong, Carol A; Spence Laschinger, Heather K; Cummings, Greta G
2010-11-01
The purpose of the present study was to test a theoretical model linking authentic leadership with staff nurses' trust in their manager, work engagement, voice behaviour and perceived unit care quality. Authentic leadership is a guide for effective leadership needed to build trust and healthier work environments because there is special attention given to honesty, integrity and high ethical standards in the development of leader-follower relationships. A non-experimental, predictive survey design was used to test the hypothesized model in a random sample of 280 (48% response rate) registered nurses working in acute care hospitals in Ontario. The final model fitted the data acceptably (χ(2)=17.24, d.f.=11, P=0.10, IFI=0.99, CFI=0.99, RMSEA=0.045). Authentic leadership significantly and positively influenced staff nurses' trust in their manager and work engagement which in turn predicted voice behaviour and perceived unit care quality. These findings suggest that authentic leadership and trust in the manager play a role in fostering trust, work engagement, voice behaviour and perceived quality of care. Nursing leaders can improve care quality and workplace conditions by paying attention to facilitating genuine and positive relationships with their staff. © 2010 The Authors. Journal compilation © 2010 Blackwell Publishing Ltd.
Mothes, A; Léotard, S; Nicolle, I; Smets, A; Chirio, D; Rotomondo, C; Tiger, F; Del Giudice, P; Perrin, C; Néri, D; Foucault, C; Della Guardia, M; Hyvernat, H; Roger, P-M
2016-10-01
The use of rapid microbiological tests is supported by antimicrobial stewardship policies. Targeted antibiotic therapy (TAT) for community-acquired pneumonia (CAP) with positive urinary antigen test (UAT) has been associated with a favorable impact on outcome. We aimed to determine the factors associated with TAT prescription. We conducted a retrospective multicenter study including all patients presenting with CAP and positive UAT for Streptococcus pneumoniae or Legionella pneumophila from January 2010 to December 2013. Patients presenting with aspiration pneumonia, coinfection, and neutropenia were excluded. CAP severity was assessed using the Pneumonia Severity Index (PSI). TAT was defined as the administration of amoxicillin for pneumococcal infection and either macrolides or fluoroquinolones (inactive against S. pneumoniae) for Legionella infection. A total of 861 patients were included, including 687 pneumococcal infections and 174 legionellosis from eight facilities and 37 medical departments. TAT was prescribed to 273 patients (32%). Four factors were found independently associated with a lower rate of TAT: a PSI score≥4 (OR 0.37), Hospital A (OR 0.41), hospitalization in the intensive care unit (OR 0.44), and cardiac comorbidities (OR 0.60). Four other factors were associated with a high rate of TAT: positive blood culture for S. pneumoniae (OR 2.32), Hospitals B (OR 2.34), E (OR 2.68), and H (OR 9.32). TAT in CAP with positive UAT was related to the hospitals as well as to patient characteristics. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Marlowe, Elizabeth M.; Hardy, David; Krevolin, Mark; Gohl, Peter; Bertram, Alexander; Arcenas, Rodney; Seiverth, Britta; Schneider, Tanja; Liesenfeld, Oliver
2017-01-01
We compared the analytical and clinical performance of cobas® CT/NG for use on the Cobas® 6800/8800 Systems with the Cobas® 4800 CT/NG Test from urogenital and extragenital specimens in over 12,000 specimens from both male and female subjects in Germany and the United States. The analytical sensitivity was ≤40 EB/ml for Chlamydia trachomatis (CT) and ≤1 CFU/ml for Neisseria gonorrhoeae (NG). Using clinical specimens, the overall percent agreement with the Cobas® 4800 CT/NG Test was >98.5%. Across urogenital specimens, there were 93 discrepant specimens; 76 (93.8%) of 81 CT discrepant specimens were 6800+/4800– and 10 (83.3%) of 12 NG discrepant specimens were 6800+/4800–. Sequencing verified CT results for 45 (61.6%) of 73 samples positive by 6800 and 1 (20%) of 5 positive by 4800. Similarly, 7 (70.0%) of 10 NG samples positive by 6800 and 1 of 2 positive by 4800 were confirmed by sequencing. Among discrepant extragenital specimens (all 6800+/4800–), 7 (50%) of 14 oropharyngeal and 23 (76.7%) of 30 anorectal CT discordant samples were confirmed as CT positive by sequencing; all 8 anorectal and 20 (90.9%) of 22 oropharyngeal NG discordant results were also confirmed as NG positive. In conclusion, Cobas® CT/NG for use on the Cobas® 6800/8800 Systems provides high-throughput automated solutions for sexually transmitted infection (STI) screening programs. PMID:29034107
Outbreak of Influenza A(H1N1) in a Kidney Transplant Unit-Protective Effect of Vaccination.
Helanterä, I; Anttila, V-J; Lappalainen, M; Lempinen, M; Isoniemi, H
2015-09-01
Seasonal influenza vaccination is recommended for patients with end-stage renal disease (ESRD), despite suggested inferior efficacy among these patients. We characterize an outbreak of influenza A(H1N1) in a kidney transplant unit. Altogether 23 patients were treated on the ward for postoperative care after kidney transplantation during the outbreak. After the first positive case, all patients were tested with nasopharyngeal swab tests and 7 patients were diagnosed with influenza A(H1N1). Altogether 17/23 patients had received adequate seasonal influenza vaccination, of whom 2/17 tested positive for influenza (one asymptomatic, one with mild cough). Five of six unvaccinated patients were diagnosed with influenza A(H1N1); 3/5 suffered from severe respiratory failure and were treated with ventilator support in the ICU, but all died due to acute respiratory distress syndrome, whereas 2/5 suffered from mild viral pneumonitis and recovered fully. The risk of influenza infection and mortality was significantly increased in unvaccinated patients (odds ratio 37.5 [95% CI 2.7-507.5, p = 0.01] and 6.7 [95% CI 2.3-18.9, p = 0.003], respectively). Influenza A(H1N1) had a high mortality in our cohort of nonvaccinated immunosuppressed patients early after kidney transplantation. None of the vaccinated patients developed serious disease, supporting the role of vaccination also for ESRD patients. © Copyright 2015 The American Society of Transplantation and the American Society of Transplant Surgeons.
NASA Astrophysics Data System (ADS)
Bhojwani, Virendra; Inamdar, Asif; Lele, Mandar; Tendolkar, Mandar; Atrey, Milind; Bapat, Shridhar; Narayankhedkar, Kisan
2017-04-01
A two-stage Stirling Cryocooler has been developed and tested for cooling IR sensors in space application. The concept uses an opposed piston linear compressor to drive the two-stage Stirling expander. The configuration used a moving coil linear motor for the compressor as well as for the expander unit. Electrical phase difference of 80 degrees was maintained between the voltage waveforms supplied to the compressor motor and expander motor. The piston and displacer surface were coated with Rulon an anti-friction material to ensure oil less operation of the unit. The present article discusses analysis results, features of the cryocooler and experimental tests conducted on the developed unit. The two-stages of Cryo-cylinder and the expander units were manufactured from a single piece to ensure precise alignment between the two-stages. Flexure bearings were used to suspend the piston and displacer about its mean position. The objective of the work was to develop a two-stage Stirling cryocooler with 2 W at 120 K and 0.5 W at 60 K cooling capacity for the two-stages and input power of less than 120 W. The Cryocooler achieved a minimum temperature of 40.7 K at stage 2.
Fractionated analysis of paired-electrode nerve recordings.
Fiore, Lorenzo; Lorenzetti, Walter; Ratti, Giovannino; Geppetti, Laura
2003-12-30
Multi-unit activity recorded from two electrodes positioned at a distance on a nerve may be analysed by cross-correlation, but units similar in direction and velocity of propagation cannot be distinguished and separately evaluated by this method. To overcome this limit, we added two features, represented by the impulse amplitudes of the paired recordings, to the dimension given by the impulse delay. The analysis was fractionated according to the new dimensions. In experimental recordings from the locomotor appendage of the lobster Homarus americanus, the fractionated analysis proved capable of identifying the contributions of single active units, even if these were superimposed and indiscernible in the global cross-correlation histogram. Up to 5 motor and 10 sensory units could be identified. The shape of the paired impulses was evaluated by an averaging procedure. Analogous evaluations on simulated recordings made it possible to estimate the influences exerted on performance by variations in noise level and in the number and firing rate of active units. The global signal could be resolved into single units even under the worst conditions. Accuracy in evaluating the amount of unit activity varied, exceeding 90% in about half of the cases tested; a similar performance was attained by evaluation of the impulse shapes.
Evaluation of diagnostic serological results in cases of suspected primary syphilis infection.
Gratzer, Beau; Pohl, Daniel; Hotton, Anna L
2014-05-01
Reverse sequence screening for syphilis, in which an automatable treponemal assay (enzyme immunoassay [EIA]/chemiluminescence assay [CIA]) is performed first and followed by a nontreponemal test for reactive specimens, has been used increasingly in the United States. The EIA is objective, efficient, and believed to be more sensitive than the rapid plasma reagin (RPR) because treponemal antibodies appear before nontreponemal antibodies. We sought to compare the sensitivity of a commonly used EIA, the Trep-Sure EIA (TS-EIA), to the RPR in cases of suspected primary syphilis infection in our clinic. A retrospective medical record review of patients with sexually transmitted infection clinic visits from January 2009 to December 2011 was conducted, and 52 patients met the following inclusion criteria: suspected primary syphilis symptoms, at least 1 positive syphilis test result at visit, and no history of syphilis. Sensitivity analyses compared the TS-EIA and RPR, using the reference standard of concordantly positive/reactive TS-EIA/RPR or positive fluorescent treponemal antibody absorption test (FTA-ABS) result. We considered equivocal TS-EIA results to be positive for sensitivity calculations because such results typically reflex to additional testing and therefore may still result in identifying new infections. Twenty-eight (53.8%) of the 52 patients had a positive or equivocal TS-EIA. Twenty-five (89.3%) of those were RPR reactive; the remaining 3 (10.7%) were RPR nonreactive, FTA-ABS positive. Forty patients (76.9%) had a positive RPR, including 15 patients (37.5%) with negative TS-EIA results; all 15 were FTA-ABS positive. Nine additional patients were TS-EIA negative and RPR nonreactive but had a positive FTA-ABS result. The RPR was significantly more sensitive than the EIA (76.9% vs. 53.8%, P = 0.005). Trep-Sure EIA positivity was also significantly associated with higher median RPR titer (P = 0.011). Use of the TS-EIA may result in underdetection of primary syphilis compared with the RPR. Further evaluation of the sensitivity of the TS-EIA in high-morbidity settings is warranted before the adoption of reverse sequence screening algorithms.
Application of low-power, high-rate PCM telemetry in a helicopter instrumentation system
NASA Technical Reports Server (NTRS)
Thomas, Mitchel E.; Diamond, John K.
1987-01-01
The use of low-power, high-rate pulse code modulation (PCM) in a helicopter instrumentation system is examined. A Helicopter Instrumentation and Recording System (HIARS) was developed to obtain main rotor blade measurements and fuselage performance measurements. The HIARS consists of a low-power PCM telemeter, a digital PCM system, an optical rotor position sensor, and a PCM decommutation unit; the components and functions of these subsystems are described. Flight tests were conducted to evaluate the ability of the HIARS to measure aircraft parameters. The test data reveal that the PCM telemetry is applicable to helicopter instrumentation systems.
Liu, Yu-Ming; Tsai, Shang-Ying; Fleck, David E; Strakowski, Stephen M.
2011-01-01
We attempted to compare executive dysfunction with Wisconsin Card Sorting Test (WCST) among distinct national and ethnic patients with bipolar disorder in euthymia. Bipolar patients, aged 16-45 years, from United States (N=25) and Taiwan (N=30) did not differ significantly on any measure. The WCST number Failure to Maintain Set was significantly positively correlated with residual affective symptoms in Taiwanese and US patients. Selective executive dysfunction in euthymia is inherent to bipolar disorder. Euthymic bipolar patients of various ethnic groups may exhibit similar executive dysfunction. PMID:21683454
Laser system for testing radiation imaging detector circuits
NASA Astrophysics Data System (ADS)
Zubrzycka, Weronika; Kasinski, Krzysztof
2015-09-01
Performance and functionality of radiation imaging detector circuits in charge and position measurement systems need to meet tight requirements. It is therefore necessary to thoroughly test sensors as well as read-out electronics. The major disadvantages of using radioactive sources or particle beams for testing are high financial expenses and limited accessibility. As an alternative short pulses of well-focused laser beam are often used for preliminary tests. There are number of laser-based devices available on the market, but very often their applicability in this field is limited. This paper describes concept, design and validation of laser system for testing silicon sensor based radiation imaging detector circuits. The emphasis is put on keeping overall costs low while achieving all required goals: mobility, flexible parameters, remote control and possibility of carrying out automated tests. The main part of the developed device is an optical pick-up unit (OPU) used in optical disc drives. The hardware includes FPGA-controlled circuits for laser positioning in 2 dimensions (horizontal and vertical), precision timing (frequency and number) and amplitude (diode current) of short ns-scale (3.2 ns) light pulses. The system is controlled via USB interface by a dedicated LabVIEW-based application enabling full manual or semi-automated test procedures.
Heat transfer unit and method for prefabricated vessel
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tamburello, David A.; Kesterson, Matthew R; Hardy, Bruce J.
Vessel assemblies, heat transfer units for prefabricated vessels, and methods for heat transfer prefabricated vessel are provided. A heat transfer unit includes a central rod, and a plurality of peripheral rods surrounding the central rod and connected to the central rod. The plurality of peripheral rods are movable between a first collapsed position and a second bowed position, wherein in the second bowed position a midpoint of each of the plurality of peripheral rods is spaced from the central rod relative to in the first position. The heat transfer unit further includes a heat transfer element connected to one ofmore » the plurality of peripheral rods.« less
Mitchell, Sheona M; Pedersen, Heather N; Eng Stime, Evelyn; Sekikubo, Musa; Moses, Erin; Mwesigwa, David; Biryabarema, Christine; Christilaw, Jan; Byamugisha, Josaphat K; Money, Deborah M; Ogilvie, Gina S
2017-01-13
Women living with HIV (WHIV) are disproportionately impacted by cervical dysplasia and cancer. The burden is greatest in low-income countries where limited or no access to screening exists. The goal of this study was to describe knowledge and intentions of WHIV towards HPV self-collection for cervical cancer screening, and to report on factors related to HPV positivity among women who participated in testing. A validated survey was administered to 87 HIV positive women attending the Kisenyi Health Unit aged 30-69 years old, and data was abstracted from chart review. At a later date, self-collection based HPV testing was offered to all women. Specimens were tested for high risk HPV genotypes, and women were contacted with results and referred for care. Descriptive statistics, Chi Square and Fischer-exact statistical tests were performed. The vast majority of WHIV (98.9%) women did not think it necessary to be screened for cervical cancer and the majority of women had never heard of HPV (96.4%). However, almost all WHIV found self-collection for cervical cancer screening to be acceptable. Of the 87 WHIV offered self-collection, 40 women agreed to provide a sample at the HIV clinic. Among women tested, 45% were oncogenic HPV positive, where HPV 16 or 18 positivity was 15% overall. In this group of WHIV engaged in HIV care, there was a high prevalence of oncogenic HPV, a large proportion of which were HPV genotypes 16 or 18, in addition to low knowledge of HPV and cervical cancer screening. Improved education and cervical cancer screening for WHIV are sorely needed; self-collection based screening has the potential to be integrated with routine HIV care in this setting.
Legislated emergency locating transmitters and emergency position indicating radio beacons
NASA Technical Reports Server (NTRS)
Wade, William R. (Inventor)
1988-01-01
An emergency locating transmitting (ELT) system is disclosed which comprises a legislated ELT modified with an interface unit and connected by a multiwire cable to a remote control monitor (RCM), typically located at the pilot position. The RCM can remotely test the ELT by disabling the legislated swept tone and allowing transmission of a single tone, turn the ELT on for legislated ELT transmission, and reset the ELT to an armed condition. The RCM also provides visual and audio indications of transmitter operating condition as well as ELT battery condition. Removing the RCM or shorting or opening the interface input connections will not affect traditional ELT operation.
Collaborative testing as a learning strategy in nursing education.
Sandahl, Sheryl S
2010-01-01
A primary goal of nursing education is to prepare nurses to work collaboratively as members of interprofessional health care teams on behalf of patients. Collaborative testing is a collaborative learning strategy used to foster knowledge development, critical thinking in decision making, and group processing skills. This study incorporated a quasi-experimental design with a comparison group to examine the effect of collaborative testing as a learning strategy on student learning and retention of course content as well as group process skills and student perceptions of their learning and anxiety. The setting was a baccalaureate nursing program; the sample consisted of two groups of senior students enrolled in Medical-Surgical Nursing II. Student learning, as measured by unit examination scores, was greater for students taking examinations collaboratively compared to individually. Retention of course content, as measured by final examination scores, was not greater for students taking examinations collaboratively compared to individually. Student perceptions were overwhelmingly positive, with students reporting increased learning as a result of the collaborative testing experiences. Despite the lack of data to support increased retention, collaborative testing may be a learning strategy worth implementing in nursing education. Students reported more positive interactions and collaboration with their peers, skills required by the professional nurse.
Pathmanathan, Nirmala; Geng, Jing-Shu; Li, Wencai; Nie, Xiu; Veloso, Januario; Hill, Julie; McCloud, Philip; Bilous, Michael
2016-12-01
Current estimates of the human epidermal growth factor receptor 2 (HER2)-positivity rate in breast cancer are largely based on studies from the United States, Europe and Australia, and might not reflect the rate among breast cancer patients in Asia. The primary aim of this study was to conduct a clinical audit of laboratories across eight countries in Asia to determine the incidence of HER2-positive breast cancer in this region. Pathology laboratories submitted data on breast cancers consecutively tested for HER2 over a two-year period. The proportion of HER2-positive, -equivocal and -negative tumors was determined for each country and overall. HER2-positivity rate by age and histological grade was also determined. HER2 results from 30 179 breast cancers were submitted by 96 laboratories. The overall HER2-positivity rate was 23.5%; the rate between countries ranged from 19.7% to 44.2%, and from 4.4% to 51.6% between laboratories. An equivocal HER2 result was recorded in 18.2% of cases. Discrepancies between laboratories suggest that testing expertise contributes to variations seen in HER2 status across laboratories, as well as the generally higher rate of HER2-positivity that was recorded. In this study, the incidence of HER2-positive breast cancer diagnosed in Asian women was higher than published studies on women from Western countries. In addition, the study found that women in Asian countries presented with breast cancer at an earlier age, with a higher histological grade. This study serves to highlight the challenges with HER2 testing and data collection in a large multicenter Asian cohort. © 2016 The Authors. Asia-Pacific Journal of Clinical Oncology Published by John Wiley & Sons Australia, Ltd.
James, Justin; Teo, Melanie; Ramachandran, Vivekananda; Law, Michael; Stoney, David; Cheng, Michael
2017-10-01
In many centres in Australia, CT scan of abdomen and pelvis (CTAP) is a commonly used staging investigation to detect asymptomatic synchronous metastasis (ASM) in newly diagnosed breast cancer. However, its routine use is not supported by strong evidence either on its cost effectiveness or on specificity. Despite contrary recommendations by international guidelines this staging investigation is widely used among new early breast cancers(EBC). This retrospective study aims to assess the cost effectiveness and usefulness of CTAP in new breast cancers. All patients with primary invasive breast cancers who underwent breast cancer treatment through Eastern health breast unit during 50-month period from January 2012 were included in the study. All staging CTAP results were reviewed to evaluate its yield, false positive rate and cost of investigation per single positive result. Odds ratio for positive test results were calculated for five possible risk factors (Age less than 40 years, stage III disease, presence of LVI, HER2 positive disease and presence of metastasis in lymph node). 49% (n = 285) of all breast cancer patient underwent staging CTAP which lead to the detection of 4 ASM. (Over all yield of 1%) Overall false positive rate was 15% because of 42 indeterminate results needing further tests. Based merely on approved billing rates this amounted to $ 40733 per single ASM identified. Presence of lymph node metastasis did not increase the chance of positive test result (OR = 1.3; CI:0.13-12.69). Staging CTAP is associated with high incidence of false positive rates and low yield, especially among EBCs. It is desirable to choose this investigation more selectively than currently practiced. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.
Early HIV Infections Among Men Who Have Sex with Men in Five Cities in the United States
Smith, A.; Masciotra, S.; Zhang, W.; Bingham, T.; Flynn, C.; German, D.; Al-Tayyib, A.; Magnus, M.; LaLota, M.; Rose, C. E.; Owen, S. M.
2016-01-01
We tested blood samples from men who have sex with men (MSM) to detect early HIV infection. Early HIV included both acute (infected past 30 days) and recent (estimated recency past 240 days). Acute infections were defined as screen immunoassay (IA) negative/NAAT-positive or IA-positive/Multispot-negative/NAAT-positive. Recent infections were defined as avidity index cutoff <30 % on an avidity-based IA and, (1) not reporting antiretroviral therapy use or, (2) HIV RNA >150 copies/mL. Of 937 samples, 26 % (244) were HIV-infected and of these 5 % (12) were early. Of early infections, 2 were acute and 10 recent; most (8/12) were among black MSM. Early infection was associated with last partner of black race [adjusted relative risk (ARR) = 4.6, confidence intervals (CI) 1.2–17.3], receptive anal sex at last sex (ARR = 4.3, CI 1.2–15.0), and daily Internet use to meet partners/ friends (ARR = 3.3, CI 1.1–9.7). Expanding prevention and treatment for black MSM will be necessary for reducing incidence in the United States. PMID:25680518
Dargatz, David A; Marshall, Katherine L; Fedorka-Cray, Paula J; Erdman, Matthew M; Kopral, Christine A
2015-12-01
Salmonella is a major cause of foodborne illness and can cause clinical disease in animals. Understanding the on-farm ecology of Salmonella will be helpful in decreasing the risk of foodborne transmission. An objective of this study was to determine the prevalence of Salmonella among fecal samples collected on sheep operations in the United States. Another objective was to compare the use of composite fecal samples with fecal samples collected from individual sheep as a tool for screening sheep flocks for Salmonella. Sheep fecal samples (individual and composite) were collected on operations in 22 states. Salmonella isolates were characterized with regard to species, serotype, and antimicrobial susceptibility profile. Most operations (72.1%) had at least one positive sample and overall 26.9% of samples were positive. The percentage of positive samples varied by animal age class. Composite and individual samples gave similar results. The majority of the isolates (94%) were Salmonella enterica subspecies diarizonae serotype 61:-:1,5,7. Nearly all of the isolates (91.2%) tested for antimicrobial susceptibility were susceptible to all antimicrobials in the panel. The findings suggest that salmonellae typically associated with foodborne disease transmission are infrequently found on sheep operations in the United States.
Ramsey, G; Soltis, F; Bowman, R; McNamee, J; Hahn, L F; Dixon, B W
1991-01-01
We report a preliminary study on whether syphilis serology might be reactive in some blood donors at risk for human immunodeficiency virus (HIV) infection. We retrospectively analyzed voluntary blood donations with reactive Treponema pallidum antibody (TPA) tests according to the type of donation, the presence of other safety markers, confidential unit exclusion, syphilis diagnosis, and HIV risk factors. Over 2 years (1987-1988), 1 in 8,900 regular homologous donations (n = 258,610) was TPA positive as compared with 1 in 2,200 directed donations (n = 6,685) and 1 in 300 autologous donations (n = 8,870; p less than 0.05 for both). The rate in directed donations was not significantly higher than in first-time regular donors (1 in 4,800; n = 57,000). TPA-positive donations had higher rates of antibody to hepatitis B core antigen and confidential unit exclusion than TPA-negative donations. Ten TPA-positive homologous or directed donors had latent or previously treated syphilis (1 in 26,500 such donations), and 2 of these had HIV risk factors. None of the autologous donors were determined to have active syphilis. Syphilis serology in blood donors bears further scrutiny as a possible surrogate marker for HIV risk.
Sommerstein, Rami; Rüegg, Christian; Kohler, Philipp; Bloemberg, Guido; Kuster, Stefan P; Sax, Hugo
2016-06-01
Heater-cooler units (HCUs) were recently identified as a source of Mycobacterium chimaera causing surgical site infections. We investigated transmission of this bacterium from HCUs to the surgical field by using a thermic anemometer and particle counter, videotape of an operating room equipped with an ultraclean laminar airflow ventilation system, and bacterial culture sedimentation plates in a nonventilated room. Smoke from the HCU reached the surgical field in 23 s by merging with ultraclean air. The HCU produced on average 5.2, 139, and 14.8 particles/min in the surgical field at positions Off, On/oriented toward, and On/oriented away, respectively. Culture plates were positive for M. chimaera <5 m from the HCU in the test room. These experiments confirm airborne transmission of M. chimaera aerosols from a contaminated HCU to an open surgical field despite ultraclean air ventilation. Efforts to mitigate infectious risks during surgery should consider contamination from water sources and airflow-generating devices.
Sommerstein, Rami; Rüegg, Christian; Kohler, Philipp; Bloemberg, Guido; Kuster, Stefan P.
2016-01-01
Heater–cooler units (HCUs) were recently identified as a source of Mycobacterium chimaera causing surgical site infections. We investigated transmission of this bacterium from HCUs to the surgical field by using a thermic anemometer and particle counter, videotape of an operating room equipped with an ultraclean laminar airflow ventilation system, and bacterial culture sedimentation plates in a nonventilated room. Smoke from the HCU reached the surgical field in 23 s by merging with ultraclean air. The HCU produced on average 5.2, 139, and 14.8 particles/min in the surgical field at positions Off, On/oriented toward, and On/oriented away, respectively. Culture plates were positive for M. chimaera <5 m from the HCU in the test room. These experiments confirm airborne transmission of M. chimaera aerosols from a contaminated HCU to an open surgical field despite ultraclean air ventilation. Efforts to mitigate infectious risks during surgery should consider contamination from water sources and airflow-generating devices. PMID:27070958
A survey of the current neonatal nurse practitioner workforce.
Cusson, R M; Buus-Frank, M E; Flanagan, V A; Miller, S; Zukowsky, K; Rasmussen, L
2008-12-01
To assess the adequacy and characteristics of the US neonatal nurse practitioner (NNP) workforce. Internet-based survey of 271 NNP conference participants. Data were analyzed using SPSS (version 14; Chicago, IL, USA); descriptive statistics, including chi(2)-tests of independence, were performed (alpha=0.05). Respondents were primarily masters-prepared females, working in level III newborn intensive care units. Unfilled NNP positions were common; time estimated to fill positions averaged 6-18 months. One-third of the respondents' practice settings had substituted other providers. The mean NNP salary was $86,700. Motivators for becoming an NNP included autonomy and increased knowledge; challenges identified were overload of responsibilities and the NNP shortage. This study provides the first data about NNP education and workforce characteristics in the United States. The use of an internet-based data collection process facilitated the rapid response of a large sample of NNPs and demonstrated the effectiveness of this method of data collection. The results of this survey suggest a mismatch between the need for NNPs the available NNP workforce supply.
Haile, Demewoz; Nigatu, Dabere; Gashaw, Ketema; Demelash, Habtamu
2016-01-01
Academic achievement of school age children can be affected by several factors such as nutritional status, demographics, and socioeconomic factors. Though evidence about the magnitude of malnutrition is well established in Ethiopia, there is a paucity of evidence about the association of nutritional status with academic performance among the nation's school age children. Hence, this study aimed to determine how nutritional status and cognitive function are associated with academic performance of school children in Goba town, South East Ethiopia. An institution based cross-sectional study was conducted among 131 school age students from primary schools in Goba town enrolled during the 2013/2014 academic year. The nutritional status of students was assessed by anthropometric measurement, while the cognitive assessment was measured by the Kaufman Assessment Battery for Children (KABC-II) and Ravens colored progressive matrices (Raven's CPM) tests. The academic performance of the school children was measured by collecting the preceding semester academic result from the school record. Descriptive statistics, bivariate and multivariable linear regression were used in the statistical analysis. This study found a statistically significant positive association between all cognitive test scores and average academic performance except for number recall (p = 0.12) and hand movements (p = 0.08). The correlation between all cognitive test scores and mathematics score was found positive and statistically significant (p < 0.05). In the multivariable linear regression model, better wealth index was significantly associated with higher mathematics score (ß = 0.63; 95 % CI: 0.12-0.74). Similarly a unit change in height for age z score resulted in 2.11 unit change in mathematics score (ß = 2.11; 95 % CI: 0.002-4.21). A single unit change of wealth index resulted 0.53 unit changes in average score of all academic subjects among school age children (ß = 0.53; 95 % CI: 0.11-0.95). A single unit change of age resulted 3.23 unit change in average score of all academic subjects among school age children (ß = 3.23; 95 % CI: 1.20-5.27). Nutritional status (height for age Z score) and wealth could be modifiable factors to improve academic performance of school age children. Moreover, interventions to improve nutrition for mothers and children may be an important contributor to academic success and national economic growth in Ethiopia. Further study with strong design and large sample size is needed.
Bruminhent, Jackrapong; Wang, Zi-Xuan; Hu, Carol; Wagner, John; Sunday, Richard; Bobik, Brent; Hegarty, Sarah; Keith, Scott; Alpdogan, Seyfettin; Carabasi, Matthew; Filicko-O'Hara, Joanne; Flomenberg, Neal; Kasner, Margaret; Outschoorn, Ubaldo Martinez; Weiss, Mark; Flomenberg, Phyllis
2014-09-01
There was an increase in the Clostridium difficile infection (CDI) rate in our bone marrow transplantation unit. To evaluate the role of unit-based transmission, C. difficile screening was performed on adult patients admitted for hematopoietic stem cell transplantation (HSCT) over a 2-year period, and C. difficile isolates were typed. C. difficile testing was performed using a 2-step C. difficile glutamate dehydrogenase antigen plus toxin A/B enzyme immunoassay (EIA) and cytotoxin assay (or molecular toxin assay). Multilocus sequence typing (MLST) was performed on toxin-positive whole stool samples. A retrospective chart review was performed on all patients with a positive toxin assay. Sixteen of 150 patients (10.7%) had toxigenic C. difficile colonization (CDC) on admission. The overall incidence of CDI within 100 days after HSCT was 24.7% (37 of 150). The median time to diagnosis of CDI was 3.5 days after HSCT. In an adjusted logistic regression model, CDC on admission was a significant risk factor for CDI (odds ratio, 68.5; 95% confidence interval, 11.4 to 416.2). MLST on 22 unit patient toxin-positive stool specimens revealed 15 distinct strain types. Further analysis identified at least 1 potential cross-transmission event; some events may have been missed because of incomplete typing from other specimens. Despite aggressive infection control interventions, there was no decline in the number of CDI cases during the study period. These data suggest that prior CDC plays a major role in CDI rates in this high-risk patient population. It remains unclear if CDI was cross-transmitted in the unit. Copyright © 2014 American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.
Food allergy in infants and children: clinical evaluation and management.
Levy, Y; Kornbroth, B; Ofer, I; Garty, B Z; Danon, Y L
1994-12-01
A total of 122 infants and children up to age 17 (69 males and 53 females) who were referred for food allergy to the Pediatric Allergy and Clinical Immunology Unit were evaluated by complete history, emphasizing the implicated foods, clinical presentation and involvement of various organ systems, physical examination, and prick skin tests to food allergens. Fourteen infants with a history of egg white allergy and positive skin tests to egg white also underwent skin tests (prick and intradermal in 1:100 dilution) to measles-mumps-rubella (MMR) vaccine; 35 children under 3 years old had 41 oral challenges with the suspected foods; and 9 children over 3 years old had 12 oral challenges with the suspected foods. We found that cow milk/humanized milk formula, egg white, soybean, and peanut are the main allergenic foods in the pediatric population. Thirteen children had 13 positive oral challenges: 12 to cow milk/humanized milk formula and one to egg white. Symptoms reproduced by oral challenges included urticarial and erythematous rash, conjunctival itching, angioedema, abdominal pain, vomiting, diarrhea, and rhinorrhea. No anaphylactic shock was reported. Negative skin test has an excellent predictive accuracy for negative oral challenge with the suspected food in children > 3 years old. The negative predictive accuracy of cow milk skin test in children < 3 years was 73%. Positive skin test is not a good predictor of a clinical reaction to food. Oral food challenge performed cautiously in a medical setting is the "gold standard" for diagnosis. MMR vaccine can be safely administered to infants with egg white allergy after skin tests with the vaccine are performed.
Gillet, Nicolas; Colombat, Philippe; Michinov, Estelle; Pronost, Anne-Marie; Fouquereau, Evelyne
2013-11-01
To test a model linking procedural justice, supervisor autonomy support, need satisfaction, organizational support, work satisfaction, organizational identification and job performance. Research in industrial and organizational psychology has shown that procedural justice and supervisor autonomy support lead to positive outcomes. However, very little research related to this subject has been conducted in healthcare settings. Moreover, few studies have examined mechanisms that could account for these positive relationships. A cross-sectional correlational design was used. Convenience sampling was used and a sample of 500 nurses working in haematology, oncology and haematology/oncology units in France was surveyed in 2011. The final sample consisted of 323 nurses (64.6% response rate). The hypothesized model was tested using structural equation modelling. Procedural justice and supervisor autonomy support significantly and positively influenced need satisfaction and perceived organizational support, which in turn positively predicted work satisfaction, organizational identification and job performance. Organizations could deliver training programmes for their managers aimed at enhancing the use of fair procedures in allocating outcomes and developing their autonomy-supportive behaviours to improve nurses' work satisfaction, organizational identification and job performance. © 2013 Blackwell Publishing Ltd.
Positive parenting, family cohesion, and child social competence among immigrant Latino families.
Leidy, Melinda S; Guerra, Nancy G; Toro, Rosa I
2010-06-01
The relation between positive parenting, family cohesion, and child social competence was examined among Latino families (predominantly from Mexico) who were recent immigrants to the United States. A mixed method study was conducted, including both pre- and post-test self-reported surveys (9-month interval) and qualitative data from focus groups. A total of 282 parents and 282 children (ages 9-12) participated in the survey study. Results at post-test follow-up indicated that family cohesion predicted improvements in child social problem-solving skills and social self-efficacy, and positive parenting predicted improvements in child social self-efficacy. A total of 12 mothers participated in the focus group study that was designed to explore barriers to positive parenting and family cohesion in this population. Results from focus groups revealed four major themes impacting parenting and family cohesion: (a) acculturation differences between parents and children and the resulting power imbalance; (b) difficulty getting involved in their child's education; (c) loss of extended family; and (d) discrimination against immigrants and legal status. The implications for family support programs for immigrant Latino families and their children are discussed. (c) 2010 APA, all rights reserved.
Lu, Jie; Li, Huimin; Dong, Fang; Shi, Jin; Yang, Hui; Han, Shujing; Chu, Ping; Zhao, Yanlin; Song, Wenqi; Guo, Yongli; Zhao, Shunying
2017-01-01
Drug resistance surveillance is crucial for control of drug-resistant tuberculosis (TB). However, limited data exists on the burden of drug-resistant TB in children. The goal of this work was to generate prevalence data regarding rifampicin- (RIF-) resistant childhood TB in northern China and to test the feasibility of Xpert for surveying pediatric TB drug resistance prevalence. We enrolled 362 clinically diagnosed childhood TB patients and collected sputum, gastric lavage aspirate (GLA), bronchoalveolar lavage fluid (BALF), and cerebral spinal fluid (CSF) samples. Xpert and solid culture were utilized to detect RIF resistance. The detection rate of Xpert-positive TB among new clinically diagnosed TB cases was 38.4% (139/362), significantly higher than that of solid culture-positive TB (16.3%, 59/362, P < 0.01). Notably, Xpert-positive rates differed significantly by sample type, with the highest positive rate for GLA (51.2%). The unit testing costs per RIF-resistant TB patient were $828.41 for solid culture and $761.86 for Xpert. Our data demonstrate that the prevalence of RIF resistance among childhood TB cases in our study (6.9%) is comparable to the national RIF resistance prevalence level of new cases (6.7%). In addition, Xpert is superior to the solid culture for RIF resistance survey in the childhood TB patients.
Peters, J A; Heunis, C; Kigozi, G; Osoba, T; van der Walt, M
2015-03-21
Integrated tuberculosis-human immunodeficiency virus (TB-HIV) service delivery as part of maternal health services, including antenatal care (ANC), is widely recommended. This study assessed the implementation of collaborative TB-HIV service delivery at a hospital-based ANC service unit. A record review of a random sample of 308 pregnant women attending the ANC service between April 2011 and February 2012 was conducted. Data were extracted from registers and patient case notes. Outcomes included the proportion of women who underwent HIV counselling and testing (HCT), CD4 count testing, antiretroviral treatment (ART), cotrimoxazole preventive treatment (CPT), TB screening and isoniazid preventive treatment (IPT). Analysis measured variations in patient characteristics associated with service delivery. All women underwent HCT; 80% of those who tested HIV-positive were screened for TB. Most (85.9%) of the HIV-positive women received a CD4 count. However, only 12.9% of eligible women received ART prophylaxis onsite, only 35.7% were referred for initiation of ART, only 42.3% commenced IPT and none received CPT or further investigations for TB. HIV-negative women had 2.6 higher odds (95%CI 1.3-5.3) of receiving TB screening than their HIV-positive counterparts. Although the identification of HIV-positive women and TB suspects was adequate, implementation of other TB-HIV collaborative activities was sub-optimal.
Li, Charles; Lillehoj, Hyun S; Gadde, Ujvala Deepthi; Ritter, Don; Oh, SungTaek
2017-06-01
Necrotic enteritis (NE) is an important enteric disease in poultry, and Clostridium perfringens (CP) type A strains are the primary etiology. NE is responsible for annual losses of US $6 billion to the poultry industry in the United States. An increase in the incidence of NE has been also associated with withdrawal of antibiotic growth promoters from poultry feed. In this study, CP strains isolated from healthy and NE-afflicted birds were characterized microbiologically and molecularly, and their virulence was experimentally tested in chickens. All strains were hemolytic, lecithinase positive, and identified as CP by biochemical tests. Three distinct colony morphologies were seen in brain-heart infusion media with 0.3% agarose, FeSO 4 , and ZnCl 2 . The CP strains responded differently to iron chelation with 2,2'-bidypinol. PCR toxinotyping showed that all tested strains were alpha toxin-positive, seven (N11, N10, CP1, CP5, CP13, JGS, and Del1) were beta2-toxin-positive, and only one (Del1) was necrotic enteritis toxin B-like-positive. In vivo studies indicated that most isolates, including strain N11 isolated from the normal chicken gut, were sufficiently virulent to produce NE disease in the Eimeria/CP dual infection model. The Del1 and N11 strains merit further investigation to identify their virulence factors and immune-protective antigens.
Implementation of a Legionella Ordinance for Multifamily Housing, Garland, Texas.
Whitney, Ellen A; Blake, Sarah; Berkelman, Ruth L
The incidence of legionellosis has sharply increased in the United States as a result of contaminated water systems. Jurisdictions across the country are considering whether to develop and implement regulations to protect individuals against Legionnaires' disease with its associated high morbidity and mortality. This article sheds light on the implementation and effectiveness of a 2005 citywide Legionella testing mandate of multifamily housing cooling towers in Garland, Texas. This ordinance has been in place for more than 10 years and represents the first of its kind in the United States to mandate routine testing of cooling towers for Legionella in multifamily housing. We utilized a mix of both qualitative and quantitative methods to explore the development, adoption, and implementation of the ordinance. Phone interviews were conducted with individuals from the City of Garland Health Department and apartment managers. Quantitative data included public health surveillance data on legionellosis. Barriers and facilitators of implementation, number and percentage of cooling towers from multifamily housing units that tested positive for Legionella by year, and number of legionellosis cases by year in Garland, Texas. Study outcomes highlight key themes that facilitated the successful implementation of the Legionella testing mandate, including the importance of timing, leadership support, stakeholder engagement, and education and outreach. The number of contaminated cooling towers was reduced over time. Mandatory monitoring for legionella in a local jurisdiction may result in reduced risk of legionellosis from cooling towers through raising awareness and education of building owners and managers about the need to prevent, detect, and remediate legionella contamination in their building water systems. Garland, Texas, broke new ground in the United States in moving toward primary prevention of legionellosis. The ordinance may be useful both in serving to educate and increase awareness about the need for Legionella prevention and to monitor effectiveness of maintenance procedures.
NASA Astrophysics Data System (ADS)
Itaoka, Kanae; Kim, In-Tae; Yamabuki, Kazuhiro; Yoshimoto, Nobuko; Tsutsumi, Hiromori
2015-11-01
Room temperature rechargeable magnesium (Mg) batteries are constructed from Mg as a negative material, sulfur (S)-containing composite prepared from elemental sulfur and the bis(alkenyl) compound having a crown ether unit (BUMB18C6) or linear ether unit (UOEE) as a positive material and the simple electrolyte (0.7 mol dm-3 Mg[N(SO2CF3)2]2-triglyme (G3) solution). The reaction between molten S and the bis(alkenyl) compound (BUMB18C6 or UOEE) provides the sulfur-containing composite, S-BUMB18C6 or S-UOEE. Both of the sulfur-containing composites are electrochemically active in the Mg salt-based electrolyte, acetonitrile- or G3- Mg[N(SO2CF3)2]2 electrolyte. The first discharge capacity of the test cells with the sulfur-containing composite is 460 Ah kg-1 (per the weight of sulfur in the composite) with the S-BUMB18C6 electrode and 495 Ah kg-1 with the S-UOEE electrode. According to the continuous charge-discharge cycle tests (at 10th cycle), the discharge capacity of the test cell with the S-BUMB18C6 electrode (68.1 Ah kg-1) is higher than that with the S-UOEE electrode (0.18 Ah kg-1). The crown ether units in the S-BUMB18C6 composite may create ion-conducting paths in the cathode, prevent rise in the internal resistance of the cathode, and provide better cycle performance of the test cells with the S-BUMB18C6 composite electrode than that with the S-UOEE electrode.
Govindasamy, Darshini; Kranzer, Katharina; van Schaik, Nienke; Noubary, Farzad; Wood, Robin; Walensky, Rochelle P.; Freedberg, Kenneth A.; Bassett, Ingrid V.; Bekker, Linda-Gail
2013-01-01
Background HIV counseling and testing may serve as an entry point for non-communicable disease screening. Objectives To determine the yield of newly-diagnosed HIV, tuberculosis (TB) symptoms, diabetes and hypertension, and to assess CD4 count testing, linkage to care as well as correlates of linkage and barriers to care from a mobile testing unit. Methods A mobile unit provided screening for HIV, TB symptoms, diabetes and hypertension in Cape Town, South Africa between March 2010 and September 2011. The yield of newly-diagnosed cases of these conditions was measured and clients were followed-up between January and November 2011 to assess linkage. Linkage to care was defined as accessing care within one, three or six months post-HIV diagnosis (dependent on CD4 count) and one month post-diagnosis for other conditions. Clinical and socio-demographic correlates of linkage to care were evaluated using Poisson regression and barriers to care were determined. Results Of 9,806 clients screened, the yield of new diagnoses was: HIV (5.5%), TB suspects (10.1%), diabetes (0.8%) and hypertension (58.1%). Linkage to care for HIV-infected clients, TB suspects, diabetics and hypertensives was: 51.3%, 56.7%, 74.1% and 50.0%. Only disclosure of HIV-positive status to family members or partners (RR=2.6, 95% CI: 1.04-6.3, p=0.04) was independently associated with linkage to HIV care. The main barrier to care reported by all groups was lack of time to access a clinic. Conclusion Screening for HIV, TB symptoms and hypertension at mobile units in South Africa has a high yield but inadequate linkage. After-hours and weekend clinics may overcome a major barrier to accessing care. PMID:24236170
França, Luís; Simões, Catarina; Taborda, Marco; Diogo, Catarina; da Costa, Milton S.
2015-01-01
Over a period of ten months a total of 5618 cord blood units (CBU) were screened for microbial contamination under routine conditions. The antibiotic resistance profile for all isolates was also examined using ATB strips. The detection rate for culture positive units was 7.5%, corresponding to 422 samples.16S rRNA sequence analysis and identification with API test system were used to identify the culturable aerobic, microaerophilic and anaerobic bacteria from CBUs. From these samples we recovered 485 isolates (84 operational taxonomic units, OTUs) assigned to the classes Bacteroidia, Actinobacteria, Clostridia, Bacilli, Betaproteobacteria and primarily to the Gammaproteobacteria. Sixty-nine OTUs, corresponding to 447 isolates, showed 16S rRNA sequence similarities above 99.0% with known cultured bacteria. However, 14 OTUs had 16S rRNA sequence similarities between 95 and 99% in support of genus level identification and one OTU with 16S rRNA sequence similarity of 90.3% supporting a family level identification only. The phenotypic identification formed 29 OTUs that could be identified to the species level and 9 OTUs that could be identified to the genus level by API test system. We failed to obtain identification for 14 OTUs, while 32 OTUs comprised organisms producing mixed identifications. Forty-two OTUs covered species not included in the API system databases. The API test system Rapid ID 32 Strep and Rapid ID 32 E showed the highest proportion of identifications to the species level, the lowest ratio of unidentified results and the highest agreement to the results of 16S rRNA assignments. Isolates affiliated to the Bacilli and Bacteroidia showed the highest antibiotic multi-resistance indices and microorganisms of the Clostridia displayed the most antibiotic sensitive phenotypes. PMID:26512991
França, Luís; Simões, Catarina; Taborda, Marco; Diogo, Catarina; da Costa, Milton S
2015-01-01
Over a period of ten months a total of 5618 cord blood units (CBU) were screened for microbial contamination under routine conditions. The antibiotic resistance profile for all isolates was also examined using ATB strips. The detection rate for culture positive units was 7.5%, corresponding to 422 samples.16S rRNA sequence analysis and identification with API test system were used to identify the culturable aerobic, microaerophilic and anaerobic bacteria from CBUs. From these samples we recovered 485 isolates (84 operational taxonomic units, OTUs) assigned to the classes Bacteroidia, Actinobacteria, Clostridia, Bacilli, Betaproteobacteria and primarily to the Gammaproteobacteria. Sixty-nine OTUs, corresponding to 447 isolates, showed 16S rRNA sequence similarities above 99.0% with known cultured bacteria. However, 14 OTUs had 16S rRNA sequence similarities between 95 and 99% in support of genus level identification and one OTU with 16S rRNA sequence similarity of 90.3% supporting a family level identification only. The phenotypic identification formed 29 OTUs that could be identified to the species level and 9 OTUs that could be identified to the genus level by API test system. We failed to obtain identification for 14 OTUs, while 32 OTUs comprised organisms producing mixed identifications. Forty-two OTUs covered species not included in the API system databases. The API test system Rapid ID 32 Strep and Rapid ID 32 E showed the highest proportion of identifications to the species level, the lowest ratio of unidentified results and the highest agreement to the results of 16S rRNA assignments. Isolates affiliated to the Bacilli and Bacteroidia showed the highest antibiotic multi-resistance indices and microorganisms of the Clostridia displayed the most antibiotic sensitive phenotypes.
Nonlinear mathematical modeling and sensitivity analysis of hydraulic drive unit
NASA Astrophysics Data System (ADS)
Kong, Xiangdong; Yu, Bin; Quan, Lingxiao; Ba, Kaixian; Wu, Liujie
2015-09-01
The previous sensitivity analysis researches are not accurate enough and also have the limited reference value, because those mathematical models are relatively simple and the change of the load and the initial displacement changes of the piston are ignored, even experiment verification is not conducted. Therefore, in view of deficiencies above, a nonlinear mathematical model is established in this paper, including dynamic characteristics of servo valve, nonlinear characteristics of pressure-flow, initial displacement of servo cylinder piston and friction nonlinearity. The transfer function block diagram is built for the hydraulic drive unit closed loop position control, as well as the state equations. Through deriving the time-varying coefficient items matrix and time-varying free items matrix of sensitivity equations respectively, the expression of sensitivity equations based on the nonlinear mathematical model are obtained. According to structure parameters of hydraulic drive unit, working parameters, fluid transmission characteristics and measured friction-velocity curves, the simulation analysis of hydraulic drive unit is completed on the MATLAB/Simulink simulation platform with the displacement step 2 mm, 5 mm and 10 mm, respectively. The simulation results indicate that the developed nonlinear mathematical model is sufficient by comparing the characteristic curves of experimental step response and simulation step response under different constant load. Then, the sensitivity function time-history curves of seventeen parameters are obtained, basing on each state vector time-history curve of step response characteristic. The maximum value of displacement variation percentage and the sum of displacement variation absolute values in the sampling time are both taken as sensitivity indexes. The sensitivity indexes values above are calculated and shown visually in histograms under different working conditions, and change rules are analyzed. Then the sensitivity indexes values of four measurable parameters, such as supply pressure, proportional gain, initial position of servo cylinder piston and load force, are verified experimentally on test platform of hydraulic drive unit, and the experimental research shows that the sensitivity analysis results obtained through simulation are approximate to the test results. This research indicates each parameter sensitivity characteristics of hydraulic drive unit, the performance-affected main parameters and secondary parameters are got under different working conditions, which will provide the theoretical foundation for the control compensation and structure optimization of hydraulic drive unit.
Proportion hyperglycosylated hCG: a new test for discriminating gestational trophoblastic diseases.
Cole, Laurence A
2014-11-01
Hyperglycosylated human chorionic gonadotropin (hCG) is a variant of hCG with large oligosaccharide side chains. Although hCG is produced by syncytiotrophoblast cells, hyperglycosylated hCG marks cytotrophoblast cell. Hyperglycosylated hCG signals placental implantation. Total hCG in serum and urine is measured by the Siemens Immulite hCG pregnancy test; the result is in milli-international unit per milliliter. Hyperglycosylated hCG is determined by the B152 microtiter plate assay; the result is in nanogram per milliliter. Hyperglycosylated hCG results can be converted to milli-international unit per milliliter equivalents by multiplying by 11. The test measures proportion hyperglycosylated hCG, hyperglycosylated hCG / total hCG. Proportion hyperglycosylated hCG marks cases intent on developing persistent hydatidiform mole (68% detection at 17% false detection). Proportion hyperglycosylated hCG also marks persistent hydatidiform mole (100% detection at 5.1% false detection). Proportion hyperglycosylated hCG distinguishes choriocarcinoma and gestational trophoblastic neoplasm cases, absolutely discriminating aggressive cases and minimally aggressive cases. Proportion hyperglycosylated hCG identifies quiescent gestational trophoblastic disease cases. It recognizes quiescent cases that become persistent disease (100% detection at 0% false positive). Proportion hyperglycosylated hCG is an invaluable test for discriminating gestational trophoblastic diseases.
Autonomous Airborne Refueling Demonstration: Phase I Flight-Test Results
NASA Technical Reports Server (NTRS)
Dibley, Ryan P.; Allen, Michael J.; Nabaa, Nassib
2007-01-01
The first phase of the Autonomous Airborne Refueling Demonstration (AARD) project was completed on August 30, 2006. The goal of this 15-month effort was to develop and flight-test a system to demonstrate an autonomous refueling engagement using the Navy style hose-and-drogue air-to-air refueling method. The prime contractor for this Defense Advanced Research Projects Agency (DARPA) sponsored program was Sierra Nevada Corporation (SNC), Sparks, Nevada. The responsible flight-test organization was the National Aeronautics and Space Administration (NASA) Dryden Flight Research Center (DFRC), Edwards, California, which also provided the F/A-18 receiver airplane (McDonnell Douglas, now The Boeing Company, Chicago, Illinois). The B-707-300 tanker airplane (The Boeing Company) was contracted through Omega Aerial Refueling Services, Inc., Alexandria, Virginia, and the optical tracking system was contracted through OCTEC Ltd., Bracknell, Berkshire, United Kingdom. Nine research flights were flown, testing the functionality and performance of the system in a stepwise manner, culminating in the plug attempts on the final flight. Relative position keeping was found to be very stable and accurate. The receiver aircraft was capable of following the tanker aircraft through turns while maintaining its relative position. During the last flight, six capture attempts were made, two of which were successful. The four misses demonstrated excellent characteristics, the receiver retreating from the drogue in a controlled, safe, and predictable manner that precluded contact between the drogue and the receiver aircraft. The position of the receiver aircraft when engaged and in position for refueling was found to be 5.5 to 8.5 ft low of the ideal position. The controller inputs to the F/A-18 were found to be extremely small.
Autonomous Airborne Refueling Demonstration, Phase I Flight-Test Results
NASA Technical Reports Server (NTRS)
Dibley, Ryan P.; Allen, Michael J.; Nabaa, Nassib
2007-01-01
The first phase of the Autonomous Airborne Refueling Demonstration (AARD) project was completed on August 30, 2006. The goal of this 15-month effort was to develop and flight-test a system to demonstrate an autonomous refueling engagement using the Navy style hose-and-drogue air-to-air refueling method. The prime contractor for this Defense Advanced Research Projects Agency (DARPA) sponsored program was Sierra Nevada Corporation (SNC), Sparks, Nevada. The responsible flight-test organization was the NASA Dryden Flight Research Center (DFRC), Edwards, California, which also provided the F/A-18 receiver airplane (McDonnell Douglas, now The Boeing Company, Chicago, Illinois). The B-707-300 tanker airplane (The Boeing Company) was contracted through Omega Aerial Refueling Services, Inc., Alexandria, Virginia, and the optical tracking system was contracted through OCTEC Ltd., Bracknell, Berkshire, United Kingdom. Nine research flights were flown, testing the functionality and performance of the system in a stepwise manner, culminating in the plug attempts on the final flight. Relative position keeping was found to be very stable and accurate. The receiver aircraft was capable of following the tanker aircraft through turns while maintaining its relative position. During the last flight, six capture attempts were made, two of which were successful. The four misses demonstrated excellent characteristics, the receiver retreating from the drogue in a controlled, safe, and predictable manner that precluded contact between the drogue and the receiver aircraft. The position of the receiver aircraft when engaged and in position for refueling was found to be 5.5 to 8.5 ft low of the ideal position. The controller inputs to the F/A-18 were found to be extremely small
Pickup, R. W.; Rhodes, G.; Bull, T. J.; Arnott, S.; Sidi-Boumedine, K.; Hurley, M.; Hermon-Taylor, J.
2006-01-01
Mycobacterium avium subsp. paratuberculosis from infected animals enters surface waters and rivers in runoff from contaminated pastures. We studied the River Tywi in South Wales, United Kingdom, whose catchment comprises 1,100 km2 containing more than a million dairy and beef cattle and more than 1.3 million sheep. The River Tywi is abstracted for the domestic water supply. Between August 2002 and April 2003, 48 of 70 (68.8%) twice-weekly river water samples tested positive by IS900 PCR. In river water, the organisms were associated with a suspended solid which was depleted by the water treatment process. Disposal of contaminated slurry back onto the land established a cycle of environmental persistence. A concentrate from 100 liters of finished water tested negative, but 1 of 54 domestic cold water tanks tested positive, indicating the potential for these pathogens to access domestic outlets. In the separate English Lake District region, with hills up to 980 m, tests for M. avium subsp. paratuberculosis in the high hill lakes and sediments were usually negative, but streams and sediments became positive lower down the catchment. Sediments from 9 of 10 major lakes receiving inflow from these catchments were positive, with sediment cores indicating deposition over at least 40 to 50 years. Two of 12 monthly 1-liter samples of effluent and a single 100-liter sample from the Ambleside sewage treatment works were positive for M. avium subsp. paratuberculosis. Since Lake Ambleside discharges into Lake Windermere, which is available for domestic supply, there is a potential for these organisms to cycle within human populations. PMID:16751517
Glick, Sara Nelson; Cleary, Sean D; Golden, Matthew R
2015-11-01
After recent civil rights expansions for sexual minorities in the United States, we updated previous findings on population-level attitudes toward homosexuality measured in the General Social Survey. In 2014, 40.1% of respondents reported that homosexuality was "always wrong" compared with 54.8% in 2008 (P < 0.001). Although black and Hispanic respondents consistently reported more negative attitudes regarding homosexuality than white respondents throughout 2008 to 2014, the percentage declined among all racial/ethnic groups. Among MSM, more positive attitudes were associated with HIV testing. Research shows a potential association between homophobia and HIV risk; thus, these population-level changes may promote better health among MSM.
2018-02-28
Gabriel Rodriguez-Mena, a United Launch Alliance systems test engineer, speaks to members of social media in the Kennedy Space Center’s Press Site auditorium. The briefing focused on the National Oceanic and Atmospheric Administration's, or NOAA's, Geostationary Operational Environmental Satellite, or GOES-S. The spacecraft is the second satellite in a series of next-generation NOAA weather satellites. It will launch to a geostationary position over the U.S. to provide images of storms and help predict weather forecasts, severe weather outlooks, watches, warnings, lightning conditions and longer-term forecasting. GOES-S is slated to lift off at 5:02 p.m. EST on March 1, 2018 aboard a United Launch Alliance Atlas V rocket.
Management team learning orientation and business unit performance.
Bunderson, J Stuart; Sutcliffe, Kathleen M
2003-06-01
Although research has suggested that teams can differ in the extent to which they encourage proactive learning and competence development among their members (a team learning orientation), the performance consequences of these differences are not well understood. Drawing from research on goal orientation and team learning, this article suggests that, although a team learning orientation can encourage adaptive behaviors that lead to improved performance, it is also possible for teams to compromise performance in the near term by overemphasizing learning, particularly when they have been performing well. A test of this proposition in a sample of business unit management teams provides strong support. The results confirm that an appropriate emphasis on learning can have positive consequences for team effectiveness.
NASA Technical Reports Server (NTRS)
Rosener, A. A.; Jonkoniec, T. G.
1975-01-01
A positive isolation disconnect was developed for component replacement in serviced liquid and gaseous spacecraft systems. Initially a survey of feasible concepts was made to determine the optimum method for fluid isolation, sealing techniques, coupling concepts, and foolproofing techniques. The top concepts were then further evaluated, including the fabrication of a semifunctional model. After all tradeoff analyses were made, a final configuration was designed and fabricated for development testing. This resulted in a 6.35 mm (1/4 inch) line and 12.7 mm (1/2 inch) line positive isolation disconnect, each unit consisting of two coupled disconnect halves, each capable of fluid isolation with essentially zero clearance between them for zero leakage upon disconnect half disengagement. An interlocking foolproofing technique was incorporated that prevents uncoupling of disconnect halves prior to fluid isolation.
Turtle, Lance; Kemp, Tim; Davies, Geraint R; Squire, S Bertie; Beeching, Nick J; Beadsworth, Michael B J
2012-06-01
to assess the usefulness of the T-SPOT.TB™ interferon-gamma release assay (IGRA), as used in a regional hospital infectious diseases unit in Northwest England, for the diagnosis of active tuberculosis. Retrospective case series. T-SPOT.TB™ test was applied to a group of 64 patients, 20 of whom had tuberculosis (mostly extra-pulmonary tuberculosis). The T-SPOT.TB™ test had a sensitivity of 83.3% and a specificity of 75% for the diagnosis of active tuberculosis, compared with culture. A positive IGRA approximately doubled the pre-test probability of disease from 0.23 to 0.5. This doubling of probability was true regardless of HIV status, though for HIV+ patients the sensitivity was lower (sensitivity 66.7%, post test probability 0.4 for a positive IGRA result). When extrapolated to the local population the test was most useful for exclusion of disease; post test probability 0.006 (or 1 in 167) for a negative IGRA result. Although it can add weight to a clinical diagnosis, T-SPOT.TB™ assay is not reliable for the diagnosis of active tuberculosis in a real world setting where the test is often used in patients with smear negative or extra-pulmonary disease. The test is useful for ruling out disease in HIV negative patients. Copyright © 2012. Published by Elsevier B.V.
Simonetti, Giovanni; Bollero, Enrico; Ciarrapico, Anna Micaela; Gandini, Roberto; Konda, Daniel; Bartolucci, Alberto; Di Primio, Massimiliano; Mammucari, Matteo; Chiocchi, Marcello; D'Alba, Fabrizio; Masala, Salvatore
2009-03-01
In June 2005 a Complex Operating Unit of Interventional Radiology (COUIR), consisting of an outpatient visit service, an inpatient admitting service with four beds, and a day-hospital service with four beds was installed at our department. Between June 2005 and May 2008, 1772 and 861 well-screened elective patients were admitted to the inpatient ward of the COUIR and to the Internal Medicine Unit (IMU) or Surgery Unit (SU) of our hospital, respectively, and treated with IR procedures. For elective patients admitted to the COUIR's inpatient ward, hospital stays were significantly shorter and differences between reimbursements and costs were significantly higher for almost all IR procedures compared to those for patients admitted to the IMU and SU (Student's t-test for unpaired data, p < 0.05). The results of the 3-year activity show that the activation of a COUIR with an inpatient admitting service, and the better organization of the patient pathway that came with it, evidenced more efficient use of resources, with the possibility for the hospital to save money and obtain positive margins (differences between reimbursements and costs). During 3 years of activity, the inpatient admitting service of our COUIR yielded a positive difference between reimbursements and effective costs of 1,009,095.35 euros. The creation of an inpatient IR service and the admission of well-screened elective patients allowed short hospitalization times, reduction of waiting lists, and a positive economic outcome.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simonetti, Giovanni; Bollero, Enrico; Ciarrapico, Anna Micaela
2009-03-15
In June 2005 a Complex Operating Unit of Interventional Radiology (COUIR), consisting of an outpatient visit service, an inpatient admitting service with four beds, and a day-hospital service with four beds was installed at our department. Between June 2005 and May 2008, 1772 and 861 well-screened elective patients were admitted to the inpatient ward of the COUIR and to the Internal Medicine Unit (IMU) or Surgery Unit (SU) of our hospital, respectively, and treated with IR procedures. For elective patients admitted to the COUIR's inpatient ward, hospital stays were significantly shorter and differences between reimbursements and costs were significantly highermore » for almost all IR procedures compared to those for patients admitted to the IMU and SU (Student's t-test for unpaired data, p < 0.05). The results of the 3-year activity show that the activation of a COUIR with an inpatient admitting service, and the better organization of the patient pathway that came with it, evidenced more efficient use of resources, with the possibility for the hospital to save money and obtain positive margins (differences between reimbursements and costs). During 3 years of activity, the inpatient admitting service of our COUIR yielded a positive difference between reimbursements and effective costs of Euro 1,009,095.35. The creation of an inpatient IR service and the admission of well-screened elective patients allowed short hospitalization times, reduction of waiting lists, and a positive economic outcome.« less
Serologic evidence of exposure of raptors to influenza A virus.
Redig, Patrick T; Goyal, Sagar M
2012-06-01
Serum or plasma samples from raptors that prey or scavenge upon aquatic birds were tested by a commercially available blocking enzyme-linked immunosorbent assay for the evidence of antibodies to influenza A virus. Samples were taken from birds (n = 616) admitted to two rehabilitation centers in the United States. In addition, samples from 472 migrating peregrine falcons (Falco peregrinus) trapped on autumnal and vernal migrations for banding purposes were also tested. Only bald eagles were notably seropositive (22/406). One each of peregrine falcon, great horned owl (Bubo virginianus), and Cooper's hawk (Accipiter cooperi) from a total of 472, 81, and 100, respectively, were also positive. None of the turkey vultures (n = 21) or black vultures (n = 8) was positive. No clinical signs referable to avian influenza were seen in any bird at the time of capture. These data indicate that, among raptors, bald eagles do have exposure to influenza A viruses.
Bucak, Ihsan Ömür
2010-01-01
In the automotive industry, electromagnetic variable reluctance (VR) sensors have been extensively used to measure engine position and speed through a toothed wheel mounted on the crankshaft. In this work, an application that already uses the VR sensing unit for engine and/or transmission has been chosen to infer, this time, the indirect position of the electric machine in a parallel Hybrid Electric Vehicle (HEV) system. A VR sensor has been chosen to correct the position of the electric machine, mainly because it may still become critical in the operation of HEVs to avoid possible vehicle failures during the start-up and on-the-road, especially when the machine is used with an internal combustion engine. The proposed method uses Chi-square test and is adaptive in a sense that it derives the compensation factors during the shaft operation and updates them in a timely fashion.
Bucak, İhsan Ömür
2010-01-01
In the automotive industry, electromagnetic variable reluctance (VR) sensors have been extensively used to measure engine position and speed through a toothed wheel mounted on the crankshaft. In this work, an application that already uses the VR sensing unit for engine and/or transmission has been chosen to infer, this time, the indirect position of the electric machine in a parallel Hybrid Electric Vehicle (HEV) system. A VR sensor has been chosen to correct the position of the electric machine, mainly because it may still become critical in the operation of HEVs to avoid possible vehicle failures during the start-up and on-the-road, especially when the machine is used with an internal combustion engine. The proposed method uses Chi-square test and is adaptive in a sense that it derives the compensation factors during the shaft operation and updates them in a timely fashion. PMID:22294906
A unique approach to estimating lateral anisotropy in complex geohydrologic environments
Halford, K.J.; Campbell, B.
2004-01-01
Aquifers in fractured rock or karstic settings are likely to have anisotropic transmissivity distributions. Aquifer tests that are performed in these settings also we frequently affected by leakage from adjacent confining units. Finite-difference models such as MODFLOW are convenient tools for estimating the hydraulic characteristics of the stressed aquifer and adjacent confining units but are poor tools for the estimation of lateral anisotropy. This limitation of finite-difference methods can be overcome by application of the spin method, a technique whereby the positions of the observation wells are rotated about the production well to estimate anisotropy and orientation. Formal parameter estimation is necessary to analyze aquifer tests because of the number of parameters that we estimated. As a test, transmissivity, anisotropy, and orientation were successfully estimated for a simple hypothetical problem with known properties. The technique also was applied to estimate hydraulic properties of the Santee Limestone/Black Mingo (SL/BM) aquifer and a leaky confining unit beneath Charleston, South Carolina. A 9-day aquifer test with an average discharge of 644 1/min was analyzed numerically. Drawdowns in the SL/BM aquifer and confining unit were simulated with a 12-layer MODFLOW model that was discretized into 81 rows of 81 columns. Simulated drawdowns at seven observation wells that ranged from 23 to 2700 m from the production well were matched to measured drawdowns. Transmissivity estimated along the minor axis ranged from 10 to 15 m2/day and along the major axis ranged from 80 to 100 m2/day. The major axis of transmissivity was oriented along compass heading 116?? (degrees clockwise from north), which agrees with geologic interpretations. Vertical hydraulic conductivity and specific storage estimates for the overlying confining unit were 4 ?? 10-5m/day and 2 ?? 10-4 1/m, respectively. ?? 2004 International Association of Hydraulic Engineering and Research.
High false-negative rate of anti-HCV among Egyptian patients on regular hemodialysis.
El-Sherif, Assem; Elbahrawy, Ashraf; Aboelfotoh, Atef; Abdelkarim, Magdy; Saied Mohammad, Abdel-Gawad; Abdallah, Abdallah Mahmoud; Mostafa, Sadek; Elmestikawy, Amr; Elwassief, Ahmed; Salah, Mohamed; Abdelbaseer, Mohamed Ali; Abdelwahab, Kouka Saadeldin
2012-07-01
Routine serological testing for hepatitis C virus (HCV) infection among hemodialysis (HD) patients is currently recommended. A dilemma existed on the value of serology because some investigators reported a high rate of false-negative serologic testing. In this study, we aimed to detect the false-negative rate of anti-HCV among Egyptian HD patients. Seventy-eight HD patients, negative for anti-HCV, anti-HIV, and hepatitis B surface antigen, were tested for HCV RNA by reverse transcriptase polymerase chain reaction (RT-PCR). In the next step, the viral load was quantified by real-time PCR in RT-PCR-positive patients. Risk factors for HCV infection, as well as clinical and biochemical indicators of liver disease, were compared between false-negative and true-negative anti-HCV HD patients. The frequency of false-negative anti-HCV was 17.9%. Frequency of blood transfusion, duration of HD, dialysis at multiple centers, and diabetes mellitus were not identified as risk factors for HCV infection. The frequency of false-negative results had a linear relation to the prevalence of HCV infection in the HD units. Timely identification of HCV within dialysis units is needed in order to lower the risk of HCV spread within the HD units. The high false-negative rate of anti-HCV among HD patients in our study justifies testing of a large scale of patients for precious assessment of effectiveness of nucleic acid amplification technology testing in screening HD patient. © 2012 The Authors. Hemodialysis International © 2012 International Society for Hemodialysis.
Microhard MHX 2420 Orbital Performance Evaluation Using RT Logic T400CS
NASA Technical Reports Server (NTRS)
Kearney, Stuart; Lombardi, Mark; Attai, Watson; Oyadomari, Ken; Al Rumhi, Ahmed Saleh Nasser; Rakotonarivo, Sebastien; Chardon, Loic; Gazulla, Oriol Tintore; Wolfe, Jasper; Salas, AlbertoGuillen;
2012-01-01
A major upfront cost of building low cost Nanosatellites is the communications sub-system. Most radios built for space missions cost over $4,000 per unit. This exceeds many budgets. One possible cost effective solution is the Microhard MHX2420, a commercial off-the-shelf transceiver with a unit cost under $1000. This paper aims to support the Nanosatellite community seeking an inexpensive radio by characterizing Microhard's performance envelope. Though not intended for space operations, the ability to test edge cases and increase average data transfer speeds through optimization positions this radio as a solution for Nanosatellite communications by expanding usage to include more missions. The second objective of this paper is to test and verify the optimal radio settings for the most common cases to improve downlinking. All tests were conducted with the aid of the RT Logic T400CS, a hardware-in-the-loop channel simulator designed to emulate real-world radio frequency (RF) link effects. This study provides recommended settings to optimize the downlink speed as well as the environmental parameters that cause the link to fail.
Anderson, Peter; Bendtsen, Preben; Spak, Fredrik; Reynolds, Jillian; Drummond, Colin; Segura, Lidia; Keurhorst, Myrna N; Palacio-Vieira, Jorge; Wojnar, Marcin; Parkinson, Kathryn; Colom, Joan; Kłoda, Karolina; Deluca, Paolo; Baena, Begoña; Newbury-Birch, Dorothy; Wallace, Paul; Heinen, Maud; Wolstenholme, Amy; van Steenkiste, Ben; Mierzecki, Artur; Okulicz-Kozaryn, Katarzyna; Ronda, Gaby; Kaner, Eileen; Laurant, Miranda G H; Coulton, Simon; Gual, Toni
2016-11-01
To test if training and support, financial reimbursement and option of referring screen-positive patients to an internet-based method of giving advice (eBI) can increase primary health-care providers' delivery of Alcohol Use Disorders Identification Test (AUDIT)-C-based screening and advice to heavy drinkers. Cluster randomized factorial trial with 12-week implementation and measurement period. Primary health-care units (PHCU) in different locations throughout Catalonia, England, the Netherlands, Poland and Sweden. A total of 120 PHCU, 24 in each of Catalonia, England, the Netherlands, Poland and Sweden. PHCUs were randomized to one of eight groups: care as usual, training and support (TS), financial reimbursement (FR) and eBI; paired combinations of TS, FR and eBI, and all of FR, TS and eBI. The primary outcome measure was the proportion of eligible adult (age 18+ years) patients screened during a 12-week implementation period. Secondary outcome measures were proportion of screen-positive patients advised; and proportion of consulting adult patients given an intervention (screening and advice to screen-positives) during the same 12-week implementation period. During a 4-week baseline measurement period, the proportion of consulting adult patients who were screened for their alcohol consumption was 0.059 per PHCU (95% CI 0.034 to 0.084). Based on the factorial design, the ratio of the logged proportion screened during the 12-week implementation period was 1.48 (95% CI = 1.13-1.95) in PHCU that received TS versus PHCU that did not receive TS; for FR, the ratio was 2.00 (95% CI = 1.56-2.56). The option of referral to eBI did not lead to a higher proportion of patients screened. The ratio for TS plus FR was 2.34 (95% CI = 1.77-3.10), and the ratio for TS plus FR plus eBI was1.68 (95% CI = 1.11-2.53). Providing primary health-care units with training, support and financial reimbursement for delivering Alcohol Use Disorders Identification Test-C-based screening and advice to heavy drinkers increases screening for alcohol consumption. Providing primary health-care units with the option of referring screen-positive patients to an internet-based method of giving advice does not appear to increase screening for alcohol consumption. © 2016 Society for the Study of Addiction.
1994-12-02
S94-47810 (2 Dec. 1994) --- Lockheed Space Operations Company workers in the Extended Duration Orbiter (EDO) Facility, located inside the Vehicle Assembly Building (VAB), carefully hoist the Orbiter Docking System (ODS) from its shipping container into a test stand. The ODS was shipped in a horizontal position to the Kennedy Space Center (KSC) from contractor Rockwell Aerospace's Downey plant. Once the ODS is upright, work can continue to prepare the hardware for the first docking of the United States Space Shuttle and Russian Space Station MIR in 1995. The ODS contains both United States-made and Russian-made hardware. The black band is Russian-made thermal insulation protecting part of the docking mechanism, also Russian-made, called the Androgynous Peripheral Docking System (APDS). A red protective cap covers the APDS itself. Other elements of the ODS, most of it protected by white United States-made thermal insulation, were developed by Rockwell, which also integrated and checked out the assembled Russian-United States system.
UnitedHealthcare experience illustrates how payers can enable patient engagement.
Sandy, Lewis G; Tuckson, Reed V; Stevens, Simon L
2013-08-01
Patient engagement is crucial to better outcomes and a high-performing health system, but efforts to support it often focus narrowly on the role of physicians and other care providers. Such efforts miss payers' unique capabilities to help patients achieve better health. Using the experience of UnitedHealthcare, a large national payer, this article demonstrates how health plans can analyze and present information to both patients and providers to help close gaps in care; share detailed quality and cost information to inform patients' choice of providers; and offer treatment decision support and value-based benefit designs to help guide choices of diagnostic tests and therapies. As an employer, UnitedHealth Group has used these strategies along with an "earn-back" program that provides positive financial incentives through reduced premiums to employees who adopt healthful habits. UnitedHealth's experience provides lessons for other payers and for Medicare and Medicaid, which have had minimal involvement with demand-side strategies and could benefit from efforts to promote activated beneficiaries.
Antibody screening in multitransfused patients: a prerequisite before each transfusion.
Lamba, Divjot S; Mittal, Kshitija; Sood, Tanvi; Bedi, Ravneet Kaur; Kaur, Paramjit; Kaur, Gagandeep
2014-10-01
Life-long red blood cell (RBC) transfusions remain the main treatment for severe thalassemia. We hereby report a case of anti S and anti Lu(a) in a β-thalassemia major patient detected incidentally on antibody screening. The patient was a known case of β-thalassemia major and was on regular blood transfusion every 3 weeks from the institute from the age of 6 months. Subsequently, on one occasion, patient's crossmatch was compatible despite positive antibody screen using microcolumn gel technique. Autocontrol and direct antiglobulin test were negative on microcolumn gel. Anti S and anti Lu(a) antibodies were identified. Blood unit found compatible was negative for S and Lu(a) antigens. Antibody titers were 1:1 for both anti S and anti Lu(a) in AHG phase using tube technique and antibodies were of IgG type. Blood unit was transfused uneventfully to the patient. Donors were traced back (last three donations) and called for repeat blood sample testing for S and Lu(a) antigen. Two out of three donors were found to be S antigen positive and one out of these two was Lu(a) antigen positive. Anti S and anti Lu(a) antibodies were again identified on patient's subsequent visit for transfusion. The present case re-emphasize the importance of antibody screening at each visit in earlier detection of antibodies in multi transfused patients. Encouraging patients to receive transfusion from one center and dedicating donors could reduce alloimmunization rate but larger studies are required. Copyright © 2014 Elsevier Ltd. All rights reserved.
Estimating and preventing hospital internal turnover of newly licensed nurses: A panel survey.
Kovner, Christine T; Djukic, Maja; Fatehi, Faridaben K; Fletcher, Jason; Jun, Jin; Brewer, Carol; Chacko, Thomas
2016-08-01
Registered nurse job turnover is an ongoing problem in the USA resulting in significant financial costs to both organizations and society. Most research has focused on organizational turnover with few studies about internal or unit-level turnover. Turnover of new nurses in hospitals has particular importance as almost 80% of new nurses work in hospitals and have higher turnover rates when compared to experienced nurses. This paper focuses on new nurses' unit-level turnover rates in hospitals. The purpose of this study is to: (1) identify factors that predict new nurses staying in the same units, positions, and job titles to inform unit-level retention strategies, and (2) examine the changes in work environment perceptions over time between nurses who remain in the same unit, position, and title to those who changed unit, position and/or title. A panel survey design was used to analyze changes over time. Participants were newly licensed registered nurses who were licensed for the first time between August 1st, 2004 and July 31st, 2005. The nurses came from metropolitan statistical areas or rural areas that were nested to reflect a nationally representative USA sample (58% response rate). The analytic sample for this study was 1335. Data were collected in January 2006 and 2007 following the Dillman total design approach. All potential respondents received paper surveys and non-responders received repeated mailings. Using multinomial regression the five variables with the largest effects on unit retention were (1) variety (positive), (2) having another job for pay (negative), (3) first basic degree (having a bachelors or higher degree increased the probability of staying), (4) negative affectivity (positive), and (5) job satisfaction (positive). Nurses who changed unit, and/or position, and/or title reported more positive change scores on a variety of work attitudes. Almost 30% of new nurses working in hospitals leave their unit, and/or position, and/or title during their first year of work. Our results point to the variables on which managers can focus to improve unit-level retention of new nurses. Although participants were from a nationally representative sample of nurses who were newly licensed in 2004-2005, with the geographical shifts in the USA population in the last 10 years the sample may not be geographically representative of new nurses who graduated in 2015. Copyright © 2016. Published by Elsevier Ltd.
Inquiry-Based Instruction and High Stakes Testing
NASA Astrophysics Data System (ADS)
Cothern, Rebecca L.
Science education is a key to economic success for a country in terms of promoting advances in national industry and technology and maximizing competitive advantage in a global marketplace. The December 2010 Program for International Student Assessment (PISA) ranked the United States 23rd of 65 countries in science. That dismal standing in science proficiency impedes the ability of American school graduates to compete in the global market place. Furthermore, the implementation of high stakes testing in science mandated by the 2007 No Child Left Behind (NCLB) Act has created an additional need for educators to find effective science pedagogy. Research has shown that inquiry-based science instruction is one of the predominant science instructional methods. Inquiry-based instruction is a multifaceted teaching method with its theoretical foundation in constructivism. A correlational survey research design was used to determine the relationship between levels of inquiry-based science instruction and student performance on a standardized state science test. A self-report survey, using a Likert-type scale, was completed by 26 fifth grade teachers. Participants' responses were analyzed and grouped as high, medium, or low level inquiry instruction. The unit of analysis for the achievement variable was the student scale score average from the state science test. Spearman's Rho correlation data showed a positive relationship between the level of inquiry-based instruction and student achievement on the state assessment. The findings can assist teachers and administrators by providing additional research on the benefits of the inquiry-based instructional method. Implications for positive social change include increases in student proficiency and decision-making skills related to science policy issues which can help make them more competitive in the global marketplace.