[New trends of customizing intraocular lens choice].
He, Shou-zhi
2006-05-01
Definition and basic principle of customizing intraocular lens choice are described. The importance of the choicing intraocular lens for individual patient is illustrated. The review emphasizes that it is surgeon's responsibility to choice the appropriate intraocular lens for the best postoperative outcome and patient's satisfaction.
21 CFR 886.4300 - Intraocular lens guide.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Intraocular lens guide. 886.4300 Section 886.4300...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4300 Intraocular lens guide. (a) Identification. An intraocular lens guide is a device intended to be inserted into the eye during surgery to direct...
21 CFR 886.3600 - Intraocular lens.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Intraocular lens. 886.3600 Section 886.3600 Food... DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3600 Intraocular lens. (a) Identification. An intraocular lens is a device made of materials such as glass or plastic intended to be implanted to replace...
Population-based Incidence of Intraocular Lens Exchange in Olmsted County, Minnesota.
Bothun, Erick D; Cavalcante, Lilian C B; Hodge, David O; Patel, Sanjay V
2018-03-01
To determine the population-based incidence of pseudophakic intraocular lens exchange in Olmsted County, Minnesota. Retrospective review of a population-based cohort. Patients undergoing pseudophakic intraocular lens exchange in Olmsted County, Minnesota, between January 1, 1986 and December 31, 2016 were identified from the Rochester Epidemiology Project medical record linkage system. Indications and outcomes were determined, and the incidence rate was calculated as cases per 1 000 000 person-years. Poisson regression analysis was used to assess changes in incidence over time, and the cumulative probability of needing a lens exchange was estimated by Kaplan-Meier analysis. Eighty cases of intraocular lens exchange were identified, yielding an overall age- and sex-adjusted incidence rate of 28.4 per million (confidence interval [CI], 22.1-34.7), which increased over the study period (P = .04). The 30-year cumulative probability of intraocular lens exchange among patients undergoing cataract surgery was 1.5% (CI, 0.6%-2.4%), increasing at a relatively constant rate. Dislocated lenses accounted for 72.5% of lens exchanges. Unplanned refractive outcome of primary cataract surgery and uveitis-glaucoma-hyphema syndrome from squared-edged haptics emerged as newer indications for intraocular lens exchange. The population-based incidence of pseudophakic intraocular lens exchange has increased over the last 30 years, and can be explained by the increase in incidence rate of cataract surgery over the same period. Surgeons should be aware of emerging indications of intraocular lens exchange, which reflect changes in lens design and increasing expectations of refractive outcomes. Copyright © 2017 Elsevier Inc. All rights reserved.
Severe pigment dispersion after iris-claw phakic intraocular lens implantation.
Galvis, Virgilio; Carreño, Néstor I; Tello, Alejandro; Laiton, Andrea N
2017-12-01
A 23-year-old female patient presented 3 months after the implantation of an Artisan® phakic intraocular lens with a severe depigmentation of the iris and peripheral anterior synechiae. Explantation of the intraocular lens and goniosynechialysis were performed. Eleven months after the explantation appearance of the iris significantly improved. There was no loss of lines of corrected distance visual acuity. Severe pigment dispersion after the implantation of an Artisan® phakic intraocular lens may happen and may require explantation of the lens. Iris depigmentation may improve with time.
Biocompatibility of poloxamer hydrogel as an injectable intraocular lens: a pilot study.
Kwon, Ji Won; Han, Young Keun; Lee, Woo Jin; Cho, Chong Su; Paik, Seung Joon; Cho, Dong Il; Lee, Jin Hak; Wee, Won Ryang
2005-03-01
To induce irreversible gelation of poloxamer, a thermosensitive polymer hydrogel, by using a photoinitiator and ultraviolet (UV) irradiation and to verify the biocompatibility and use of poloxamer as an injectable intraocular lens (IOL) material. Department of Ophthalmology, Seoul National University College of Medicine, Seoul Artificial Eye Center, Clinical Research Institute, Seoul National University Hospital, Seoul, Korea. In 10 rabbits, endocapsular phacoemulsification was performed and a poloxamer-photoinitiator mixture was injected into the capsular bag through a small capsulorhexis site. In 1 eye, the capsulorhexis site was closed with a small plug and the entire eye was irradiated with UV light for 5 minutes. Postoperatively, poloxamer transparency and effect on the conjunctiva, cornea, iris, vitreous, and retina were observed. A mixture comprising 25% poloxamer and 0.01% photoinitiator produced a poloxamer that remained transparent in the lens capsule for up to 6 months. No inflammatory response or toxicity was observed in the conjunctiva, cornea, iris, vitreous, or retina. Poloxamer is a potentially suitable material for an injectable IOL. Further study is needed.
Relationship of the actual thick intraocular lens optic to the thin lens equivalent.
Holladay, J T; Maverick, K J
1998-09-01
To theoretically derive and empirically validate the relationship between the actual thick intraocular lens and the thin lens equivalent. Included in the study were 12 consecutive adult patients ranging in age from 54 to 84 years (mean +/- SD, 73.5 +/- 9.4 years) with best-corrected visual acuity better than 20/40 in each eye. Each patient had bilateral intraocular lens implants of the same style, placed in the same location (bag or sulcus) by the same surgeon. Preoperatively, axial length, keratometry, refraction, and vertex distance were measured. Postoperatively, keratometry, refraction, vertex distance, and the distance from the vertex of the cornea to the anterior vertex of the intraocular lens (AV(PC1)) were measured. Alternatively, the distance (AV(PC1)) was then back-calculated from the vergence formula used for intraocular lens power calculations. The average (+/-SD) of the absolute difference in the two methods was 0.23 +/- 0.18 mm, which would translate to approximately 0.46 diopters. There was no statistical difference between the measured and calculated values; the Pearson product-moment correlation coefficient from linear regression was 0.85 (r2 = .72, F = 56). The average intereye difference was -0.030 mm (SD, 0.141 mm; SEM, 0.043 mm) using the measurement method and +0.124 mm (SD, 0.412 mm; SEM, 0.124 mm) using the calculation method. The relationship between the actual thick intraocular lens and the thin lens equivalent has been determined theoretically and demonstrated empirically. This validation provides the manufacturer and surgeon additional confidence and utility for lens constants used in intraocular lens power calculations.
21 CFR 886.4300 - Intraocular lens guide.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4300 Intraocular lens guide. (a) Identification. An intraocular lens guide is a device intended to be inserted into the eye during surgery to direct... lenses, the device is exempt from the premarket notification procedures in subpart E of part 807 of this...
Professor Peter Choyce: an early pioneer of intraocular lenses and corneal/refractive surgery.
Pandey, Suresh K; Apple, David J
2005-06-01
Professor Peter Choyce, FRCS, DOMS, MS, was one of the pioneers of intraocular lens implant surgery. He developed an interest in artificial lens implantation following cataract surgery, a procedure that was widely criticized by the ophthalmic establishment in the UK, Europe, North America and other countries. Owing to the opposition to the intraocular lenses, Peter Choyce together with Sir Harold Ridley co-founded the International Intraocular Implant Club in 1966, which was responsible for the gradual acceptance of artificial lens implantation. Peter Choyce developed several models of intraocular lens, but did not patent the majority of them. The Choyce Mark IX, manufactured by Rayner Intraocular Lenses, became the first US Food and Drug Administration-approved intraocular lens in 1981. A review of Peter Choyce's record confirms a significant number of original innovations in the field of anterior segment surgery, including many procedures taken for granted today, but not associated with his name. These include early work on both kerato- and intraocular lens-refractive procedures, keratoprosthesis, pioneering paediatric implant procedures and others. Unfortunately his tenacious adherence to anterior chamber lens technology, while in general clinically sound, caused many to question his influence and hence he remained poorly understood even until after his death. He passed away on 8 August 2001 after a long fight with colon cancer. In this article, we provide evidence and elaborate Peter Choyce's accomplishments, which places him as one of the most innovative ophthalmologist in his surgical field in the twentieth century.
Goh, Yi Wei; Misra, Stuti; Patel, Dipika V; McGhee, Charles N J
2013-03-01
The majority of those with keratoconus can maximise visual acuity with spectacle or contact lens correction as they age; however, as subjects enter their sixties, cataracts may supervene and contact lens tolerance diminishes with consequent reduction in visual acuity. Following cataract extraction, the complex refractive error associated with keratoconus may not be readily corrected by an intraocular lens alone. This report highlights the planned implantation of a primary posterior chamber toric intraocular lens with a secondary piggyback, sulcus-based, intraocular lens in advanced but stable keratoconus with extreme myopic astigmatism and cataract. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.
Pilger, Daniel; Homburg, David; Brockmann, Tobias; Torun, Necip; Bertelmann, Eckart; von Sonnleithner, Christoph
2018-04-01
The purpose of this study was to assess the clinical outcome after a bilateral implantation of an extended depth of focus intraocular lens in comparison to a monofocal intraocular lens. Department of Ophthalmology, Charité-Medical University Berlin, Germany. A total of 60 eyes of 30 patients were enrolled in this prospective, single-center study. The cataract patients underwent phacoemulsification with bilateral implantation of a TECNIS ® Symfony (Abbott Medical Optics, Santa Ana, CA, USA, 15 patients) or a TECNIS Monofocal ZCB00 (Abbott Medical Optics, Santa Ana, CA, USA, 15 patients). Postoperative evaluations were performed after 1 and 3 months, including visual acuities at far, intermediate, and near distance. Mesopic, scotopic vision, and contrast sensitivity were investigated. Aberrometry was performed using an iTrace aberrometer with a pupil scan size of 5.0 mm. After 3 months, the TECNIS Symfony group reached an uncorrected visual acuity at far distance of -0.02 logMAR compared to -0.06 logMAR in the TECNIS Monofocal group ( p = 0.03). Regarding the uncorrected vision at intermediate and near distance the following values were obtained: intermediate visual acuity -0.13 versus 0.0 logMAR (TECNIS Symfony vs TECNIS Monofocal, p = 0.001) and near visual acuity 0.11 versus 0.26 logMAR (TECNIS Symfony vs TECNIS Monofocal, p = 0.001). Low-contrast visual acuities were 0.27 versus 0.20 logMar (TECNIS Symfony vs TECNIS Monofocal, p = 0.023). The TECNIS Symfony intraocular lens can be considered an appropriate alternative to multifocal intraocular lenses because of good visual results at far, intermediate, and near distance as well as in low-contrast vision.
Pigment dispersion syndrome associated with intraocular lens implantation: a new surgical technique.
Canut Jordana, M Isabel; Pérez Formigó, Daniel; Abreu González, Rodrigo; Nadal Reus, Jeroni
2010-11-11
We report the case of a myopic patient who, after intraocular lens transplant in the posterior chamber, suffered elevated intraocular pressure due to pigment dispersion, with recurrent episodes of blurred vision. The patient was treated with a new surgical technique that can avoid potential iridolenticular contact. Complete ophthalmologic examination and optical coherence tomography (OCT) of the anterior segment were performed. Contact between the pigmentary epithelium and the iris with an intraocular lens was revealed by utrasound biomicroscopy and OCT. In this case, Nd:YAG laser iridotomy and laser iridoplasty were not effective for iridolenticular separation and control of the pigment dispersion. We propose a new technique: stitches on the surface of the iris to obtain good iridolenticular separation and good intraocular pressure control. Stitches on the iris surface should be considered as optional therapy in pigmentary glaucoma secondary to intraocular lens implantation. This surgical technique can avoid potential iridolenticular contacts more definitively.
Hemkeppler, E; Böhm, M; Kohnen, T
2018-05-29
A 52-year-old highly myopic female patient was implanted with a multifocal, diffractive, toric intraocular lens because of the wish to be independent of eyeglasses. Despite high-quality, extensive preoperative examinations, a hyperopic refractive error remained postoperatively, which led to the patient's dissatisfaction. This error was treated with Laser-in-situ-Keratomileusis (LASIK). After corneal LASIK treatment and implantation of a diffractive toric multifocal intraocular lens the patient showed a good postoperative visual result without optical phenomena.
Processes for manufacturing multifocal diffractive-refractive intraocular lenses
NASA Astrophysics Data System (ADS)
Iskakov, I. A.
2017-09-01
Manufacturing methods and design features of modern diffractive-refractive intraocular lenses are discussed. The implantation of multifocal intraocular lenses is the most optimal method of restoring the accommodative ability of the eye after removal of the natural lens. Diffractive-refractive intraocular lenses are the most widely used implantable multifocal lenses worldwide. Existing methods for manufacturing such lenses implement various design solutions to provide the best vision function after surgery. The wide variety of available diffractive-refractive intraocular lens designs reflects the demand for this method of vision correction in clinical practice and the importance of further applied research and development of new technologies for designing improved lens models.
Szabó, Antal; Papp, András; Borbándy, Ágnes; D Géhl, Zsuzsanna; Nagy, Zoltán Zsolt; Resch, Miklós
2017-01-01
The correction of aphakia might be a challenge for the surgeon. The aim of this study is to describe the authors' experience with the implantation of the retropupillary iris clip intraocular lens. Patients between January 2014 and December 2015 were included in the retrospective study. Retropupillary implantation of iris clip intraocular lens VRSA 54 (AMO Advanced Medical Optics, USA) was performed in all cases. The minimum follow up period was three months. The stability of the intraocular lens and the intraoperative and postoperative complications and the visual acuity were evaluated. During this time period 11 cases (1 female, 10 males) were included in the study. The mean age at the time of the implantation was 57.7 years (between 25-74 years). In 4 cases the iris clip lens was implanted during the first intervention, in 7 cases during the secondary procedure. In all cases the lens was fixated onto the iris posteriorly. The best corrected visual acuity before the iris clip implantation was 0.43 (0.1-1.0) and postoperatively at the time of the follow up 0.49 (0.04-1.0). With the use of the retropupillary implanted iris clip intraocular lens all of the patients could have been rehabilitated without major complications. Orv. Hetil., 2017, 158(1), 20-24.
Venter, Jan A; Oberholster, Andre; Schallhorn, Steven C; Pelouskova, Martina
2014-04-01
To evaluate refractive and visual outcomes of secondary piggyback intraocular lens implantation in patients diagnosed as having residual ametropia following segmental multifocal lens implantation. Data of 80 pseudophakic eyes with ametropia that underwent Sulcoflex aspheric 653L intraocular lens implantation (Rayner Intraocular Lenses Ltd., East Sussex, United Kingdom) to correct residual refractive error were analyzed. All eyes previously had in-the-bag zonal refractive multifocal intraocular lens implantation (Lentis Mplus MF30, models LS-312 and LS-313; Oculentis GmbH, Berlin, Germany) and required residual refractive error correction. Outcome measurements included uncorrected distance visual acuity, corrected distance visual acuity, uncorrected near visual acuity, distance-corrected near visual acuity, manifest refraction, and complications. One-year data are presented in this study. The mean spherical equivalent ranged from -1.75 to +3.25 diopters (D) preoperatively (mean: +0.58 ± 1.15 D) and reduced to -1.25 to +0.50 D (mean: -0.14 ± 0.28 D; P < .01). Postoperatively, 93.8% of eyes were within ±0.50 D and 98.8% were within ±1.00 D of emmetropia. The mean uncorrected distance visual acuity improved significantly from 0.28 ± 0.16 to 0.01 ± 0.10 logMAR and 78.8% of eyes achieved 6/6 (Snellen 20/20) or better postoperatively. The mean uncorrected near visual acuity changed from 0.43 ± 0.28 to 0.19 ± 0.15 logMAR. There was no significant change in corrected distance visual acuity or distance-corrected near visual acuity. No serious intraoperative or postoperative complications requiring secondary intraocular lens removal occurred. Sulcoflex lenses proved to be a predictable and safe option for correcting residual refractive error in patients diagnosed as having pseudophakia. Copyright 2014, SLACK Incorporated.
Zhao, Yang; Yang, Ke; Li, Jiaxin; Huang, Yang; Zhu, Siquan
2017-11-01
Posterior capsular opacification (PCO) is a common long-term complication of cataract surgery. Intraocular lens design and material have been implicated in influencing the development of PCO. This study evaluated the association of hydrophobic and hydrophilic intraocular lenses on preventing PCO. Medline, Cochrane, EMBASE, and Google Scholar databases were searched until August 3, 2016, using the following search terms: cataract, posterior capsule opacification, and intraocular lens. Eligible studies included randomized controlled trials (RCTs), retrospective, and cohort studies. Eleven studies were included in the study with a total of 889 eyes/patients. The overall analysis revealed that hydrophobic intraocular lenses were associated with lower Nd:YAG laser capsulotomy rates than hydrophilic lenses [odds ratio (OR) = 0.38, 95% confidence interval (95% CI) = 0.16-0.91, P = .029]. Hydrophobic intraocular lenses were also associated with lower subjective PCO score (diff. in means: -1.32, 95% CI = -2.39 to -0.25, P = .015) and estimated PCO score (diff. in means: -2.23; 95% CI, -3.80 to -0.68, P = .005) as compared with hydrophilic lenses. Objective PCO score was similar between lens types. (diff. in means: -0.075; 95% CI, -0.18 to 0.035; P = .182). Pooled analysis found that visual acuity was similar between hydrophobic and hydrophilic intraocular lenses (diff. in means: -0.016; 95% CI, -0.041 to 0.009, P = .208). In general, PCO scores and the rate of Nd:YAG laser capsulotomy were influenced by intraocular lens biomaterial. Lens made of hydrophobic biomaterial were overall superior in lowering the PCO score and the Nd:YAG laser capsulotomy rate, but not visual acuity.
Zhao, Yang; Yang, Ke; Li, Jiaxin; Huang, Yang; Zhu, Siquan
2017-01-01
Abstract Background: Posterior capsular opacification (PCO) is a common long-term complication of cataract surgery. Intraocular lens design and material have been implicated in influencing the development of PCO. This study evaluated the association of hydrophobic and hydrophilic intraocular lenses on preventing PCO. Methods: Medline, Cochrane, EMBASE, and Google Scholar databases were searched until August 3, 2016, using the following search terms: cataract, posterior capsule opacification, and intraocular lens. Eligible studies included randomized controlled trials (RCTs), retrospective, and cohort studies. Results: Eleven studies were included in the study with a total of 889 eyes/patients. The overall analysis revealed that hydrophobic intraocular lenses were associated with lower Nd:YAG laser capsulotomy rates than hydrophilic lenses [odds ratio (OR) = 0.38, 95% confidence interval (95% CI) = 0.16–0.91, P = .029]. Hydrophobic intraocular lenses were also associated with lower subjective PCO score (diff. in means: −1.32, 95% CI = −2.39 to −0.25, P = .015) and estimated PCO score (diff. in means: −2.23; 95% CI, −3.80 to −0.68, P = .005) as compared with hydrophilic lenses. Objective PCO score was similar between lens types. (diff. in means: −0.075; 95% CI, −0.18 to 0.035; P = .182). Pooled analysis found that visual acuity was similar between hydrophobic and hydrophilic intraocular lenses (diff. in means: −0.016; 95% CI, −0.041 to 0.009, P = .208). Conclusion: In general, PCO scores and the rate of Nd:YAG laser capsulotomy were influenced by intraocular lens biomaterial. Lens made of hydrophobic biomaterial were overall superior in lowering the PCO score and the Nd:YAG laser capsulotomy rate, but not visual acuity. PMID:29095259
Magnetically adjustable intraocular lens.
Matthews, Michael Wayne; Eggleston, Harry Conrad; Pekarek, Steven D; Hilmas, Greg Eugene
2003-11-01
To provide a noninvasive, magnetic adjustment mechanism to the repeatedly and reversibly adjustable, variable-focus intraocular lens (IOL). University of Missouri-Rolla, Rolla, and Eggleston Adjustable Lens, St. Louis, Missouri, USA. Mechanically adjustable IOLs have been fabricated and tested. Samarium and cobalt rare-earth magnets have been incorporated into the poly(methyl methacrylate) (PMMA) optic of these adjustable lenses. The stability of samarium and cobalt in the PMMA matrix was examined with leaching studies. Operational force testing of the magnetic optics with emphasis on the rotational forces of adjustment was done. Prototype optics incorporating rare-earth magnetic inserts were consistently produced. After 32 days in solution, samarium and cobalt concentration reached a maximum of 5 ppm. Operational force measurements indicate that successful adjustments of this lens can be made using external magnetic fields with rotational torques in excess of 0.6 ounce inch produced. Actual lenses were remotely adjusted using magnetic fields. The magnetically adjustable version of this IOL is a viable and promising means of handling the common issues of postoperative refractive errors without the requirement of additional surgery. The repeatedly adjustable mechanism of this lens also holds promise for the developing eyes of pediatric patients and the changing needs of all patients.
21 CFR 886.3600 - Intraocular lens.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intraocular lens. 886.3600 Section 886.3600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL... the natural lens of an eye. (b) Classification. Class III. (c) Date PMA or notice of completion of a...
Pan, Qintuo; Yang, Zhengwei; Chen, Xiaomeng; Wei, Wenlong; Ke, Zhisheng; Chen, Ding; Huang, Fang; Cai, Junyong; Zhao, Zhenquan
2018-04-01
To describe the clinical outcomes of traumatic aphakic eyes with corneal astigmatism after using a novel technique for toric intraocular lens suture fixation. In total, 12 eyes of 12 patients who underwent a new scleral suture fixation technique of one-piece toric intraocular lens (SN6AT series, Alcon Inc., TX, USA) were included in our retrospective study. Preoperative patient status, postoperative visual acuity and refractive outcomes, postoperative intraocular lens rotation, tilt, decentration, and complications were analyzed. The mean follow-up was 11.6 ± 1.0 months. The mean preoperative best-corrected visual acuity was 0.55 ± 0.32 in the logarithm of minimum angle of resolution equivalent; the postoperative best-corrected visual acuity was 0.45 ± 0.34. The mean preoperative total corneal astigmatism was 2.51 ± 1.67 D. The mean postoperative residual astigmatism was 0.77 ± 0.54 D. The mean intraocular lens rotation was 3.33° ± 1.37° (range, 1°-6°). The mean intraocular lens tilt in horizontal direction was 3.64° ± 1.02° (range, 2.6°-6.3°) and in vertical direction it was 3.19° ± 1.07 ° (range, 1.6°-5.2°). The mean intraocular lens decentration in horizontal direction was 0.14 ± 0.03 mm (range, 0.089-0.192 mm) and in vertical direction it was 0.15 ± 0.02 mm (range, 0.113-0.181 mm). One patient had mild vitreous hemorrhage and two other patients had high postoperative residual sphere and astigmatism, respectively. But no other serious complications were observed. Scleral suture fixation of foldable toric intraocular lens to correct corneal astigmatism can be a safe and effective alternative technique to manage traumatic aphakic eyes that lack adequate capsular support.
Capitena, Cara E; Gamett, Kevin; Pantcheva, Mina B
2016-10-01
To report a case of delayed presentation of a severed acrylic single-piece intraocular lens (IOL) haptic fragment causing corneal edema after uneventful phacoemulsification surgery. An 85-year-old male presented with inferior corneal decompensation six months after a reportedly uneventful phacoemulsification in his left eye. A distal haptic fragment of an acrylic single-piece posterior chamber intraocular lens was found in the inferior anterior chamber angle. Intraoperative examination revealed that the dislocated fragment originated from the temporal haptic, the remainder of which was adherent to the anterior surface of the capsular bag. The clipped edge of the haptic fragment showed a clean, flat surface, suggesting it was severed by a sharp object. The findings were considered consistent with cutting of the fragment during implantation presumably from improper lens loading, improper implantation technique, or defective implantation devices. This is the first case report of a foldable acrylic intraocular lens severed during routine uncomplicated cataract surgery that was not noted at the time of the surgery or in the immediate postoperative period. Delayed presentation of severed IOL fragments should be considered in cases of late onset corneal edema post-operatively, when other causes have been ruled out. Careful implantation technique and thorough examination of the intraocular lens after implantation to assess for lens damage intraoperatively is essential to avoid such rare complications.
Kiyokawa, Masatoshi; Sakuma, Toshiro; Hatano, Noriko; Mizota, Atsushi; Tanaka, Minoru
2009-06-01
The purpose of this article is to report the characteristics and advantages of using a newly designed quartz contact lens with slit illumination from an operating microscope for intraocular surgery. The new contact lens is made of quartz. The lens is convex-concave and is used in combination with slit illumination from an operating microscope. The optical properties of quartz make this lens less reflective with greater transmittance. The combination of a quartz contact lens with slit illumination provided a brighter and wider field of view than conventional lenses. This system enabled us to perform bimanual vitrectomy and scleral buckling surgery without indirect ophthalmoscope. Small intraocular structures in the posterior pole or in the periphery were detected more easily. In conclusion, the newly designed quartz lens with slit beam illumination from an operating microscope provided a bright, clear and wide surgical field, and allowed intraocular surgery to be performed more easily.
Kim, Yong Joon; Ha, Seung Joo
2013-01-01
To report a case of pupillary block glaucoma associated with spontaneous crystalline lens subluxation into the anterior chamber in a 34-year-old man. Dry vitrectomy was performed for securing enough retrolental space, and an intracapsular lens extraction was then performed via a corneolimbal incision. Additional endothelial cell damage was avoided with an injection of viscoelastics and gentle extraction of the crystalline lens. After deepening of the anterior chamber, scleral fixation of the intraocular lens was performed with an ab externo technique. Two months after the operation, a well-fixated intraocular lens was observed and intraocular pressure was stable. The postoperative corneal astigmatism was -3.5 dpt, and the patient had a best-corrected visual acuity of 20/25. Postoperative complications included decreased endothelial cell count and sector iris paralysis near the incision site. An anteriorly subluxated crystalline lens can cause pupillary block glaucoma in healthy young adults. To prevent intraoperative complications, intracapsular lens extraction with dry vitrectomy can be a good surgical option. The endothelial cell density should be closely monitored after surgery.
Wang, Rui; Bi, Chun-Chao; Lei, Chun-Ling; Sun, Wen-Tao; Wang, Shan-Shan; Dong, Xiao-Juan
2014-01-01
AIM To describe clinical findings and complications from cases of traumatic lens subluxation/dislocation in patients with secondary glaucoma, and discuss the multiple treating methods of operation combined with primary intraocular lens (IOL) implantation. METHODS Non-comparative retrospective observational case series. Participants: 30 cases (30 eyes) of lens subluxation/dislocation in patients with secondary glaucoma were investigated which accepted the surgical treatment by author in the Ophthalmology of Xi'an No.4 Hospital from 2007 to 2011. According to the different situations of lens subluxation/dislocation, various surgical procedures were performed such as crystalline lens phacoemulsification, crystalline lens phacoemulsification combined anterior vitrectomy, intracapsular cataract extraction combined anterior vitrectomy, lensectomy combined anterior vitrectomy though peripheral transparent cornea incision, pars plana lensectomy combined pars plana vitrectomy, and intravitreal cavity crystalline lens phacofragmentation combined pars plana vitrectomy. And whether to implement trabeculectomy depended on the different situations of secondary glaucoma. The posterior chamber intraocular lenses (PC-IOLs) were implanted in the capsular-bag or trassclerally sutured in the sulus decided by whether the capsular were present. Main outcome measures: visual acuity, intraocular pressure, the situation of intraocular lens and complications after the operations. RESULTS The follow-up time was 11-36mo (21.4±7.13). Postoperative visual acuity of all eyes were improved; 28 cases maintained IOP below 21 mm Hg; 2 cases had slightly IOL subluxation, 4 cases had slightly tilted lens optical area; 1 case had postoperative choroidal detachment; 4 cases had postoperative corneal edema more than 1wk, but eventually recovered transparent; 2 cases had mild postoperative vitreous hemorrhage, and absorbed 4wk later. There was no postoperative retinal detachment, IOL dislocation, and endophthalmitis. CONCLUSION To take early treatment of traumatic lens subluxation/dislocation in patients with secondary glaucoma by individual surgical plan based on the different eye conditions would be safe and effective, which can effectively control the intraocular pressure and restore some vision. PMID:24790868
Symbolic algebra approach to the calculation of intraocular lens power following cataract surgery
NASA Astrophysics Data System (ADS)
Hjelmstad, David P.; Sayegh, Samir I.
2013-03-01
We present a symbolic approach based on matrix methods that allows for the analysis and computation of intraocular lens power following cataract surgery. We extend the basic matrix approach corresponding to paraxial optics to include astigmatism and other aberrations. The symbolic approach allows for a refined analysis of the potential sources of errors ("refractive surprises"). We demonstrate the computation of lens powers including toric lenses that correct for both defocus (myopia, hyperopia) and astigmatism. A specific implementation in Mathematica allows an elegant and powerful method for the design and analysis of these intraocular lenses.
NASA Astrophysics Data System (ADS)
Wu, Chen; Aglyamov, Salavat R.; Liu, Chih-Hao; Han, Zhaolong; Singh, Manmohan; Larin, Kirill V.
2017-02-01
Many ocular diseases such as glaucoma and uveitis can lead to the elevation of intraocular pressure (IOP). Previous research implies a link between elevated IOP and lens disease. However, the relationship between IOP elevation and biomechanical properties of the crystalline lens has not been directly studied yet. In this work, we investigated the biomechanical properties of porcine lens as a function of IOP by acoustic radiation force optical coherence elastography.
NASA Astrophysics Data System (ADS)
Yang, Que; Wang, Shanshan; Wang, Kai; Zhang, Chunyu; Zhang, Lu; Meng, Qingyu; Zhu, Qiudong
2015-08-01
For normal eyes without history of any ocular surgery, traditional equations for calculating intraocular lens (IOL) power, such as SRK-T, Holladay, Higis, SRK-II, et al., all were relativley accurate. However, for eyes underwent refractive surgeries, such as LASIK, or eyes diagnosed as keratoconus, these equations may cause significant postoperative refractive error, which may cause poor satisfaction after cataract surgery. Although some methods have been carried out to solve this problem, such as Hagis-L equation[1], or using preoperative data (data before LASIK) to estimate K value[2], no precise equations were available for these eyes. Here, we introduced a novel intraocular lens power estimation method by accurate ray tracing with optical design software ZEMAX. Instead of using traditional regression formula, we adopted the exact measured corneal elevation distribution, central corneal thickness, anterior chamber depth, axial length, and estimated effective lens plane as the input parameters. The calculation of intraocular lens power for a patient with keratoconus and another LASIK postoperative patient met very well with their visual capacity after cataract surgery.
Ladi, Jeevan S; Shah, Nitant A
2013-01-01
We report the first case of vertical fixation by fibrin glue-assisted secondary posterior chamber intraocular lens implantation in a case of surgical aphakia. Advantages of vertical fixation are discussed. PMID:23514650
The Fyodorov Sputnik intraocular lens.
Kwitko, M L
1979-04-01
The author has implanted 197 Fyodorov intraocular lenses. With careful selection of patients, good surgical judgment, and meticulous surgery, a degree of success can be obtained with this lens, which will equal that of conventional cataract surgery. The surgical technique of implantation will be described.
McCafferty, Sean J; Schwiegerling, Jim T
2015-04-01
Present an analysis methodology for developing and evaluating accommodating intraocular lenses incorporating a deformable interface. The next generation design of extruded gel interface intraocular lens is presented. A prototype based upon similar previously in vivo proven design was tested with measurements of actuation force, lens power, interface contour, optical transfer function, and visual Strehl ratio. Prototype verified mathematical models were used to optimize optical and mechanical design parameters to maximize the image quality and minimize the required force to accommodate. The prototype lens produced adequate image quality with the available physiologic accommodating force. The iterative mathematical modeling based upon the prototype yielded maximized optical and mechanical performance through maximum allowable gel thickness to extrusion diameter ratio, maximum feasible refractive index change at the interface, and minimum gel material properties in Poisson's ratio and Young's modulus. The design prototype performed well. It operated within the physiologic constraints of the human eye including the force available for full accommodative amplitude using the eye's natural focusing feedback, while maintaining image quality in the space available. The parameters that optimized optical and mechanical performance were delineated as those, which minimize both asphericity and actuation pressure. The design parameters outlined herein can be used as a template to maximize the performance of a deformable interface intraocular lens. The article combines a multidisciplinary basic science approach from biomechanics, optical science, and ophthalmology to optimize an intraocular lens design suitable for preliminary animal trials.
Development and experimental verification of an intraocular scattering model
NASA Astrophysics Data System (ADS)
Jiang, Chong-Jhih; Jhong, Tian-Siang; Chen, Yi-Chun; Sun, Ching-Cherng
2011-10-01
An intraocular scattering model was constructed in human eye model and experimentally verified. According to the biometric data, the volumetric scattering in crystalline lens and diffusion at retina fundus were developed. The scattering parameters of cornea, including particle size and obscuration ratio, were varied to make the veiling luminance of the eye model matching the CIE disability glare general formula. By replacing the transparent lens with a cataractous lens, the disability glare curve of cataracts was generated and compared with that of transparent lenses. The MTF of the intraocular scattering model showed nice correspondence with the data measured by a double-pass experiment.
History and development of the apodized diffractive intraocular lens.
Davison, James A; Simpson, Michael J
2006-05-01
The ReSTOR intraocular lens presents a unique apodized diffractive design within a refractive foldable acrylic optic, which makes an unprecedented level of mulifocal optical performance available. We describe the history and principles of diffractive optics used in the development of this refractive-diffractive IOL.
Caça, Ihsan; Sakalar, Yildirim Bayezit; Ari, Seyhmus; Alakus, Fuat; Dogan, Eyüp
2008-01-01
We evaluated the results of simultaneous bilateral cataract extraction with intraocular lens (IOL) inplantation 32 pediatric cataract patients. Simultaneous cataract extraction and posterior capsulotomy with anterior vitrectomy and IOL implantation is an effective and safe procedure in bilateral pediatric cataracts treatment.
Ram, Jagat; Gupta, Nishant; Chaudhary, Manish; Verma, Neelam
2013-01-01
Background: A new emerging complication of trans-scleral fixation of posterior chamber (PC) intraocular lens (IOL) with polypropylene suture is high rates of spontaneous dislocation of the IOL due to disintegration or breakage of suture. Materials: We report a new surgical technique of trans-scleral fixation of posterior chamber intraocular lens (SF PCIOL) with steel suture to eliminate the complication of dislocation of IOL fixed with polypropylene suture in one adult and a child. Results: We successfully achieved stable fixation and good centration of IOL after SF PCIOL with steel suture in these patient having inadequate posterior capsular support. Both eyes achieved best corrected visual acuity 20/40 at 18 months follow-up. Conclusions: Steel suture is a viable option for trans-scleral fixation of posterior chamber intraocular lens. PMID:23619504
Simple technique to treat pupillary capture after transscleral fixation of intraocular lens.
Jürgens, Ignasi; Rey, Amanda
2015-01-01
We describe a simple surgical technique to manage pupillary capture after previous transscleral fixation of an intraocular lens. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Bilateral phacoemulsification and intraocular lens implantation in a great horned owl.
Carter, Renee T; Murphy, Christopher J; Stuhr, Charles M; Diehl, Kathryn A
2007-02-15
A great horned owl of estimated age < 1 year that was captured by wildlife rehabilitators was evaluated because of suspected cataracts. Nuclear and incomplete cortical cataracts were evident in both eyes. Ocular ultrasonography revealed no evidence of retinal detachment, and electroretinography revealed normal retinal function. For visual rehabilitation, cataract surgery was planned and intraocular lens design was determined on the basis of values obtained from the schematic eye, which is a mathematical model representing a normal eye for a species. Cataract surgery and intraocular lens placement were performed in both eyes. After surgery, refraction was within -0.75 diopters in the right eye and -0.25 diopters in the left eye. Visual rehabilitation was evident on the basis of improved tracking and feeding behavior, and the owl was eventually released into the wild. In raptors with substantial visual compromise, euthanasia or placement in a teaching facility is a typical outcome because release of such a bird is unacceptable. Successful intraocular lens implantation for visual rehabilitation and successful release into the wild are achievable.
Kleinmann, Guy; Apple, David J; Chew, Jesse; Hunter, Brian; Stevens, Scott; Larson, Scott; Mamalis, Nick; Olson, Randall J
2006-10-01
To evaluate the ability and safety of a hydrophilic acrylic intraocular lens (IOL) as a drug-delivery system for commercially available gatifloxacin and moxifloxacin. David J. Apple, MD, Laboratories for Ophthalmic Research, John A. Moran Eye Center, Department of Ophthalmology and Visual Sciences, University of Utah, Salt Lake City, Utah, USA. Thirty rabbits were divided into 2 similar groups. In Group A (15 rabbits, 30 eyes), hydrophilic acrylic IOLs (C-flex, Rayner Intraocular Lenses, Ltd.) presoaked for 24 hours in commercially available solutions of gatifloxacin 3 mg/mL or moxifloxacin 5 mg/mL were implanted after evacuation of the crystalline lens. Group B (15 rabbits, 30 eyes) had topical preoperative and postoperative cataract prophylaxis with gatifloxacin 3 mg/mL or moxifloxacin 5 mg/mL; IOLs that were not presoaked were also implanted after evacuation of the crystalline lenses. In both groups, aqueous humor samples were taken 4, 8, or 12 hours after IOL implantation (5 eyes at each time point) to determine the antibiotic concentrations. Clinical examinations were performed 24 hours postoperatively. The antibiotic concentrations in Group A (presoaked IOLs) were statistically significantly higher than those in Group B (topical) for both antibiotics in all postoperative samples except moxifloxacin at 12 hours. In both groups, there was no statistically significant difference between the concentrations of the 2 antibiotics. No eye showed signs of clinical toxicity. Results show the C-flex IOL is a safe and effective drug-delivery system for fourth-generation fluoroquinolones.
An Intraocular Camera for Retinal Prostheses: Restoring Sight to the Blind
NASA Astrophysics Data System (ADS)
Stiles, Noelle R. B.; McIntosh, Benjamin P.; Nasiatka, Patrick J.; Hauer, Michelle C.; Weiland, James D.; Humayun, Mark S.; Tanguay, Armand R., Jr.
Implantation of an intraocular retinal prosthesis represents one possible approach to the restoration of sight in those with minimal light perception due to photoreceptor degenerating diseases such as retinitis pigmentosa and age-related macular degeneration. In such an intraocular retinal prosthesis, a microstimulator array attached to the retina is used to electrically stimulate still-viable retinal ganglion cells that transmit retinotopic image information to the visual cortex by means of the optic nerve, thereby creating an image percept. We describe herein an intraocular camera that is designed to be implanted in the crystalline lens sac and connected to the microstimulator array. Replacement of an extraocular (head-mounted) camera with the intraocular camera restores the natural coupling of head and eye motion associated with foveation, thereby enhancing visual acquisition, navigation, and mobility tasks. This research is in no small part inspired by the unique scientific style and research methodologies that many of us have learned from Prof. Richard K. Chang of Yale University, and is included herein as an example of the extent and breadth of his impact and legacy.
de Medeiros, André Lins; de Araújo Rolim, André Gustavo; Motta, Antonio Francisco Pimenta; Ventura, Bruna Vieira; Vilar, César; Chaves, Mário Augusto Pereira Dias; Carricondo, Pedro Carlos; Hida, Wilson Takashi
2017-01-01
Purpose The purpose of this study was to compare the visual outcomes and subjective visual quality between bilateral implantation of a diffractive trifocal intraocular lens, Alcon Acrysof IQ® PanOptix® TNFT00 (group A), and blended implantation of an extended depth of focus lens, J&J Tecnis Symfony® ZXR00 with a diffractive bifocal intraocular lens, J&J Vision Tecnis® ZMB00 (group B). Methods This prospective, nonrandomized, consecutive, comparative study included the assessment of 40 eyes in 20 patients implanted with multifocal intraocular lens. Exclusion criteria were existence of any corneal, retina, or optic nerve disease, previous eye surgery, illiteracy, previous refractive surgery, high axial myopia, expected postoperative corneal astigmatism of >1.00 cylindrical diopter (D), and intraoperative or postoperative complications. Binocular visual acuity was tested in all cases. Ophthalmological evaluation included the measurement of uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), and uncorrected intermediate visual acuity (UIVA), with the analysis of contrast sensitivity (CS), and visual defocus curve. Results Postoperative UDVA was 0.01 and −0.096 logMAR (p<0.01) in groups A and B, respectively; postoperative CDVA was −0.07 and −0.16 logMAR (p<0.01) in groups A and B, respectively; UIVA was 0.14 and 0.20 logMAR (p<0.01) in groups A and B, respectively; UNVA was −0.03 and 0.11 logMAR (p<0.01) in groups A and B, respectively. Under photopic conditions group B had better CS at low frequencies with and without glare. Conclusion Both groups promoted good quality of vision for long, intermediate, and short distances. Group B exhibited a better performance for very short distances and for intermediate and long distances ≥−1.50 D of vergence. Group A exhibited a better performance for UIVA at 60 cm and for UNVA at 40 cm. PMID:29138533
Salazar, M.A.; Foreman, L.R.
1997-07-08
This invention describes a method for fabricating an intraocular lens made from clear Teflon{trademark}, Mylar{trademark}, or other thermoplastic material having a thickness of about 0.025 millimeters. These plastic materials are thermoformable and biocompatable with the human eye. The two shaped lenses are bonded together with a variety of procedures which may include thermosetting and solvent based adhesives, laser and impulse welding, and ultrasonic bonding. The fill tube, which is used to inject a refractive filling material is formed with the lens so as not to damage the lens shape. A hypodermic tube may be included inside the fill tube. 13 figs.
Salazar, Mike A.; Foreman, Larry R.
1997-01-01
This invention describes a method for fabricating an intraocular lens made rom clear Teflon.TM., Mylar.TM., or other thermoplastic material having a thickness of about 0.025 millimeters. These plastic materials are thermoformable and biocompatable with the human eye. The two shaped lenses are bonded together with a variety of procedures which may include thermosetting and solvent based adhesives, laser and impulse welding, and ultrasonic bonding. The fill tube, which is used to inject a refractive filling material is formed with the lens so as not to damage the lens shape. A hypodermic tube may be included inside the fill tube.
Pérez-Cambrodí, Rafael José; Piñero-Llorens, David Pablo; Ruiz-Fortes, Juan Pedro; Blanes-Mompó, Francisco Javier; Cerviño-Expósito, Alejandro
2014-07-01
We describe a case report of a patient that was implanted with a posterior chamber phakic intraocular lens (Phakic Refractive Lens, PRL) for the correction of moderate myopia and who developed postoperatively a fixed mydriasis compatible with an Urrets-Zavalia Syndrome (UZS). Specifically, a sudden acute increase of IOP in the left eye was observed in the immediate postoperative period. After IOP stabilization, the refractive result was good, but a fixed and mydriatic pupil appeared. This condition led the patient to experience visual discomfort, halos, and glare associated with high levels of higher-order aberrations in spite of the good visual result. A tinted-contact lens was fitted in order to minimize those symptoms. The UZS should be considered as a possible complication after implantation of posterior chamber phakic intraocular lenses.
Introduction to the development of intraocular lens
NASA Astrophysics Data System (ADS)
Li, Yifan; Peng, Runling; Hu, Shuilan; Wei, Maowei; Chen, Jiabi
2013-08-01
In order to cure the cataract disease or injuries in eyes, intraocular lens(IOL) has been studied all the time to replace the crystalline lens in human eyes. Researches on IOL are started early from 19th century, and it develops greatly in the hundreds years after. This article introduces several main kinds of IOLs that appear in the development history of IOL, and raises the double-liquid zoom IOL based on electrowetting, which will be the trend of IOL study.
Arthur, Stella; Steed, Lisa L.; Apple, David J.; Peng, Qun; Howard, Gene; Escobar-Gomez, Marcela
2001-01-01
Scedosporium prolificans is a soil saprophyte that is associated with a large variety of infectious processes and with respiratory colonization in immunocompetent and immunocompromised patients. We report the first described case of S. prolificans keratouveitis associated with the intraocular long-term retention of a contact lens in a 76-year-old female patient. PMID:11724890
Asymptomatic snowflake degeneration in a polymethyl methacrylate (PMMA) intraocular lens implant.
Tan, Lee T; Shuttleworth, Garry N
2008-01-01
Snowflake degeneration is a late complication of polymethyl methacrylate (PMMA) intraocular lens implants. We report a case of asymptomatic advanced snowflake opacification presenting 13 years after implantation who maintained a visual acuity of 6/6. This report serves to illustrate the variability of the clinical effects of snowflake degeneration, which do not necessarily correlate with slit-lamp appearances.
Neodymium:YAG laser cutting of intraocular lens haptics.
Gorn, R A; Steinert, R F
1985-11-01
Neodymium:YAG laser cutting of polymethylmethacrylate and polypropylene anterior chamber and posterior chamber intraocular lens haptics was studied in terms of ease of transection and physical structure of the cut areas as seen by scanning electron microscopy. A marked difference was discovered, with the polymethylmethacrylate cutting easily along transverse planes, whereas the polypropylene resisted cutting along longitudinal fibers. Clinical guidelines are presented.
Jing, Wu; Guanlu, Liang; Qianyin, Zheng; Shuyi, Li; Fengying, He; Jian, Liu; Wen, Xu
2017-07-01
A meta-analysis to compare iris-claw intraocular lens (IC-IOL) and scleral-fixated posterior chamber intraocular lens (SF-PCIOL) implantations in correcting aphakia without sufficient capsular support. Eligible studies were collected through PubMed, Web of Science, Embase, and the Cochrane library. The pooled relative risks (RR), pooled standardized mean difference (SMD), and their 95% confidence interval of the eligible studies were then calculated. Seven studies met our inclusion criteria, involving 232 and 158 eyes in IC-IOL and SF-PCIOL groups, respectively. The pooled SMD of the mean postoperative corrected distance visual acuity (CDVA) (logMAR) was -0.25. The pooled RR of the eyes achieving 20/40 or better postoperatively was 1.16. The pooled SMD of the surgical time was -2.97. The pooled RR of the surgical complications was 0.86. The pooled RR of IOL dislocation, retinal detachment (RD), and cystoid macular edema (CME) between the two groups were 0.22, 0.63, and 0.64. Implantation of IC-IOL has a more simple procedure and shorter learning curve than SF-PCIOL implantation in correcting aphakia without sufficient capsular support.
Advanced pigment dispersion glaucoma secondary to phakic intraocular collamer lens implant.
Ye, Clara; Patel, Cajal K; Momont, Anna C; Liu, Yao
2018-06-01
We report a case of pigment dispersion glaucoma secondary to uncomplicated phakic intraocular collamer lens (ICL) (Visian ICL™, Staar Inc., Monrovia, CA) implant that resulted in advanced visual field loss. A 50-year-old man presented for routine follow-up status post bilateral phakic intraocular collamer lens (ICL) placement 8 years earlier. He was incidentally found to have a decline in visual acuity from an anterior subcapsular cataract and elevated intraocular pressure (IOP) in the left eye. There were signs of pigment dispersion and no evidence of angle closure. Diffuse optic nerve thinning was consistent with advanced glaucomatous visual field defects. Pigment dispersion was also present in the patient's right eye, but without elevated IOP or visual field defects. The patient was treated with topical glaucoma medications and the phakic ICL in the left eye was removed concurrently with cataract surgery to prevent further visual field loss. Pigment dispersion glaucoma is a serious adverse outcome after phakic ICL implantation and regular post-operative monitoring may prevent advanced visual field loss.
Matsushima, Hiroyuki; Mukai, Kouichiro; Obara, Yoshitaka; Yoshida, Shinichiro; Clark, John I
2004-01-01
To analyze selected lens cytoskeletal proteins in posterior capsule opacification (PCO) 2 weeks after intraocular lens (IOL) implantation in rabbits. Department of Ophthalmology, Dokkyo University School of Medicine, Tochigi, Japan. Eight 10-week-old albino rabbits were prepared and anesthetized for phacoemulsification and aspiration of the crystalline lens and implantation of an acrylic or a hydrogel IOL. Two weeks postoperatively, the rabbits were killed and the IOLs removed for immunohistochemistry. Deparaffinized tissue sections were processed with antibodies against alpha-smooth muscle actin (alpha-SMA) and beta-crystallin to observe the types of PCO with the 2 IOL types. The proteins in the PCO tissue and the normal lens were homogenized, centrifuged, and analyzed using SDS-polyacrylamide gel electrophoresis (SDS-PAGE) densitometric analysis and Western immunoblotting for actin and vimentin. Immunohistochemistry demonstrated a fibroblastic cell type expressing alpha-SMA and partial regeneration of epithelial cells, resulting in a lenticular structure that stained irregularly for beta-crystallin. The immunoreactivity of fibroblast-like cells to beta-crystallin appeared weaker than that of the regenerated lenticular structure. SDS-PAGE showed variability in the content of cytoskeletal proteins in the insoluble fractions of the PCO. Degradation of the cytoskeletal components was greater with the acrylic IOL than with the hydrogel IOL. Cytoskeletal proteins expressed during the formation of PCO and IOL implantation may have potential as therapeutic target proteins to improve the biocompatibility of IOLs.
Intraocular lens bioactivity tested using rabbit corneal tissue cultures.
Linnola, R J; Salonen, J I; Happonen, R P
1999-11-01
To evaluate the effects of different intraocular lens (IOL) materials on epithelial cell growth to test the sandwich theory; i.e., a bioactivity-based explanation of posterior capsule opacification (PCO) after cataract surgery. Central Hospital, Vaasa, and Institute of Dentistry and Turku Center for Biomaterials, University of Turku, Finland. Rabbit corneal tissue cultures were set up on poly(methyl methacrylate) (PMMA), heparin-surface-modified (HSM) PMMA, silicone, acrylate, and hydrogel IOLs for 1 week. The tissue consisted of intact epithelium and half the thickness of the corneal stroma, which was placed against the IOL. The growth of the epithelium was examined by light microscopy to evaluate the attachment of the corneal explant to the IOL surface. All tissue samples grew well under the culture conditions. When grown on PMMA, HSM PMMA, silicone, and hydrogel, the tissue did not attach to the IOL or the epithelium grew around the explant, suggesting that the attachment of the stroma to the IOL was poor or nonexistent. Some explants on acrylate IOLs attached directly to the IOL surface with no epithelial ingrowth between the stroma and the IOL. This tissue culture method can be used to examine the behavior of corneal tissue in contact with different IOL materials. The results suggest that the acrylate IOL may have bioactive properties. This, with the lens optic's square edge, may hinder lens epithelial cell proliferation and thus prevent PCO.
Sallet, Guy
2017-01-01
We report the case of an emmetropic 32-year-old female with decreased uncorrected visual acuity and diplopia due to intermittent episodes of spasm of the near reflex. Neurologic, general, and ophthalmic examination could not find an organic cause. Attempts at spontaneous recovery, psychogenic therapy, and cycloplegic therapy were unsuccessful and the symptoms persisted for almost 5 years, leading to psychogenic distress. Final treatment with refractive lens exchange and implantation of a toric trifocal intraocular lens resolved the spasm of the near reflex, resulting in an uncorrected distance and near visual acuity of 20/20. PMID:29422856
[Complications after refractive surgery abroad].
Terzi, E; Kern, T; Kohnen, T
2008-05-01
In this article a retrospective analysis of patients presenting at a German university following refractive surgery abroad is presented. A total of 20 cases of patients who had undergone treatment between 1998 and 2006 in China (1 case), Greece (1 case), Iran (1 case), Russia (2 cases), Switzerland (1 case), Slovakia (1 case), Spain (2 cases), South Africa (3 cases), Turkey (6 cases) and the USA (2 cases) were analyzed retrospectively. The following complications were observed: epithelial ingrowth into the interface with or without melting of the flap (6 cases), corneal ectasia (2 cases), dislocation of a phakic posterior chamber intraocular lens and prolapse into the anterior chamber with endothelial cell loss (1 case), secondary increase of intraocular pressure following implantation of a phakic intraocular lens (1 case), flap-related complications following laser-in-situ keratomileusis (LASIK) (2 cases), keratitis (1 case), dislocation of the complete flap (1 case), diffuse lamellar keratitis (DLK) grade IV (1 case), hyperopia as a consequence of radial keratotomy (1 case), and under correction/over correction and poor optical quality following laser epithelial keratomileusis (LASEK) and LASIK for high myopia (5 cases) with possible early corneal ectasia. There are four important problems arising from refractive surgery abroad, often referred to as "LASIK tourism": wrong indications, insufficient management of complications, lack of postoperative care and the health economic aspect.
[Refraction after Implantation of Multifocal and Presbyopia-Correcting Intraocular Lenses].
Kretz, F T A; Linz, K; Mueller, M; Gerl, M; Koss, M J; Gerl, R H; Auffarth, G U
2015-08-01
Nowadays, further developments in the field of intraocular lenses offer a higher level of spectacle independence for our patients. As light gets scattered on different focal points a wider range of defocus is created. This greater defocus area makes it more difficult for us to determine the objective or subjective refraction. This contribution is concerned with the difficulties of measuring visual acuity in different intraocular lens designs and different measurement distances. Measuring refraction after implantation of a multifocal intraocular lens is a complex procedure and the experience of the examiner plays a crucial role. Retinoscopy, keratometry and the defocus curve are reliable methods for testing, while the auto refractometer, bichromatic testing and the cross-cylinder have limitations. Georg Thieme Verlag KG Stuttgart · New York.
Werner, Liliana; Pandey, Suresh K; Izak, Andrea M; Vargas, Luis G; Trivedi, Rupal H; Apple, David J; Mamalis, Nick
2004-05-01
To evaluate the development of capsular bag opacification in rabbit eyes after implantation of an intraocular lens (IOL) designed to minimize contact between the anterior capsule and the IOL and ensure expansion of the capsular bag. David J. Apple, MD Laboratories for Ophthalmic Devices Research, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Ten New Zealand white rabbits had a study IOL (new accommodating silicone IOL [Synchrony, Visiogen, Inc.]) implanted in 1 eye and a control IOL (1-piece plate silicone IOL with large fixation holes) implanted in the other eye. Intraocular lens position, anterior capsule opacification (ACO), and posterior capsule opacification (PCO) were qualitatively assessed using slitlamp retroillumination photographs of the dilated eyes. Anterior capsule opacification and PCO were graded on a 0 to 4 scale after the eyes were enucleated (Miyake-Apple posterior and anterior views after excision of the cornea and iris). The eyes were also evaluated histopathologically. The rate of ACO and PCO was significantly higher in the control group. Fibrosis and ACO were almost absent in the study group; the control group exhibited extensive capsulorhexis contraction, including capsulorhexis occlusion. Postoperative IOL dislocation into the anterior chamber and pupillary block syndrome were observed in some eyes in the study group. The special design features associated with the study IOL appeared to help prevent PCO. Complications in the study group were probably caused by the increased posterior vitreous pressure in rabbit eyes compared to human eyes and the relatively large size of the study IOL relative to the anterior segment of rabbit eyes.
Chung, Jin Kwon; Shin, Jin Hee; Lee, Sung Jin
2013-10-25
We present two cases of transient vacuolar changes in the anterior subcapsular space of the crystalline lens in patients after posterior chamber phakic intraocular lens implantation. Implantable collamer lenses (ICL) were implanted in healthy myopic patients. Vacuolar changes developed just after the irrigating procedure through the narrow space between the ICL and the crystalline lens. Slit-lamp examinations and spectral domain optical coherence tomography showed bleb-like lesions in the anterior subcapsular space of one eye in each case, though the lesions gradually improved without visual deterioration. Consequently, the lesions turned into a few anterior subcapsular small faint opacities. Direct irrigation of the narrow space confined by the ICL and the crystalline lens is at risk for the development of vacuolar changes in the crystalline lens. The observed spontaneous reversal indicates that surgeons should not rush to surgical intervention but rather opt for close follow over several weeks.
Valentini, Simona; Castagnetti, Carolina; Musella, Vincenzo; Spinella, Giuseppe
2014-01-01
Objective of this study was to describe intraocular measurements in newly born foals (1-7 days of age) and assess the association between globe measurements and gender, laterality, and body weight. B-scan ultrasonographic biometry was performed on both eyes of 22 healthy foals (44 eyes) ages 1-7 days using a 10-MHz transducer. Intraocular measurements (anterior chamber depth, central lens thickness, vitreous chamber depth, axial globe length, longitudinal globe length, lens poles distance) were carried out using the ultrasound internal calipers. The influence of gender (male or female), laterality (right or left eye), and body weight ("light" <48 kg; "heavy" ≥48 kg) on ocular measurements was analysed by the Student t test. Values of P<0.05 were accepted as significant for all analyses. Mean anterior chamber depth was 2.2±0.5 mm (Standard Deviation); central lens thickness was 9.9±0.8 mm; vitreous chamber depth was 15.5±1.1 mm; axial globe length was 27.6±1.6 mm; longitudinal globe length was 35.8±1.2 mm, and lens poles distance was 16.4±1.0 mm. Intraocular measurements were not influenced by gender, laterality nor body weight. This study provides reference values for intraocular measurements in neonatal foals and may be useful in the diagnosis and treatment of congenital and acquired pathologies involving the globe.
Valentini, Simona; Castagnetti, Carolina; Musella, Vincenzo; Spinella, Giuseppe
2014-01-01
Objective of this study was to describe intraocular measurements in newly born foals (1–7 days of age) and assess the association between globe measurements and gender, laterality, and body weight. B-scan ultrasonographic biometry was performed on both eyes of 22 healthy foals (44 eyes) ages 1–7 days using a 10-MHz transducer. Intraocular measurements (anterior chamber depth, central lens thickness, vitreous chamber depth, axial globe length, longitudinal globe length, lens poles distance) were carried out using the ultrasound internal calipers. The influence of gender (male or female), laterality (right or left eye), and body weight (“light” <48 kg; “heavy” ≥48 kg) on ocular measurements was analysed by the Student t test. Values of P<0.05 were accepted as significant for all analyses. Mean anterior chamber depth was 2.2±0.5 mm (Standard Deviation); central lens thickness was 9.9±0.8 mm; vitreous chamber depth was 15.5±1.1 mm; axial globe length was 27.6±1.6 mm; longitudinal globe length was 35.8±1.2 mm, and lens poles distance was 16.4±1.0 mm. Intraocular measurements were not influenced by gender, laterality nor body weight. This study provides reference values for intraocular measurements in neonatal foals and may be useful in the diagnosis and treatment of congenital and acquired pathologies involving the globe. PMID:25296286
Azuara-Blanco, Augusto; Burr, Jennifer; Ramsay, Craig; Cooper, David; Foster, Paul J; Friedman, David S; Scotland, Graham; Javanbakht, Mehdi; Cochrane, Claire; Norrie, John
2016-10-01
Primary angle-closure glaucoma is a leading cause of irreversible blindness worldwide. In early-stage disease, intraocular pressure is raised without visual loss. Because the crystalline lens has a major mechanistic role, lens extraction might be a useful initial treatment. From Jan 8, 2009, to Dec 28, 2011, we enrolled patients from 30 hospital eye services in five countries. Randomisation was done by a web-based application. Patients were assigned to undergo clear-lens extraction or receive standard care with laser peripheral iridotomy and topical medical treatment. Eligible patients were aged 50 years or older, did not have cataracts, and had newly diagnosed primary angle closure with intraocular pressure 30 mm Hg or greater or primary angle-closure glaucoma. The co-primary endpoints were patient-reported health status, intraocular pressure, and incremental cost-effectiveness ratio per quality-adjusted life-year gained 36 months after treatment. Analysis was by intention to treat. This study is registered, number ISRCTN44464607. Of 419 participants enrolled, 155 had primary angle closure and 263 primary angle-closure glaucoma. 208 were assigned to clear-lens extraction and 211 to standard care, of whom 351 (84%) had complete data on health status and 366 (87%) on intraocular pressure. The mean health status score (0·87 [SD 0·12]), assessed with the European Quality of Life-5 Dimensions questionnaire, was 0·052 higher (95% CI 0·015-0·088, p=0·005) and mean intraocular pressure (16·6 [SD 3·5] mm Hg) 1·18 mm Hg lower (95% CI -1·99 to -0·38, p=0·004) after clear-lens extraction than after standard care. The incremental cost-effectiveness ratio was £14 284 for initial lens extraction versus standard care. Irreversible loss of vision occurred in one participant who underwent clear-lens extraction and three who received standard care. No patients had serious adverse events. Clear-lens extraction showed greater efficacy and was more cost-effective than laser peripheral iridotomy, and should be considered as an option for first-line treatment. Medical Research Council. Copyright © 2016 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY license. Published by Elsevier Ltd.. All rights reserved.
Technology needs for the development of the accommodative intraocular lens
NASA Astrophysics Data System (ADS)
Nishi, Okihiro
2010-02-01
Refilling the lens capsule while preserving capsular integrity offers the potential to restore ocular accommodation. There are two persisting problems in capsular bag refilling for possible clinical application: Leakage of the injectable material through the capsular opening and capsular opacification. Numerous attempts for solving these cardinal problems have not been proven to be clinically applicable. Recently, we developed a novel capsular bag refilling procedure using a novel accommodative intraocular lens that serves as an optic as well as a plug for sealing the capsular opening. The procedure and the results of monkey experiments will be presented.
Development of fibrin-free intraocular lens with photochemical surface modification
NASA Astrophysics Data System (ADS)
Sato, Yuji; Tanizawa, Katsuya; Anai, Hiroyuki; Sato, Nobuhiro; Sato, Yuki; Ajiki, Tooru; Parel, Jean-Marie; Murahara, Masataka
2004-07-01
Having substituted the hydrophilic and hydrophobic groups alternately on the soft acrylic resin intraocular lens (IOL) surface by using an ArF excimer laser and a Xe2 excimer lamp, we have developed the IOL that is free from fibrin. Acrylic resin or PMMA lens has been used as an intraocular lens for 50 years. However, protein and fat are stuck onto the IOL surface after a long implantation, which opacifies the surface (after-cataract). Thus, we designed the micro domain structures of hydrophilic and hydrophobic groups on the IOL surface for fibrin-free. Firstly, the IOL was irradiated with the Xe2 excimer lamp in the presence of perfluoropolyether in order to make it hydrophobic. By this photochemical reaction, the CF3 functional groups were substituted on the IOL surface. Secondly, the ArF laser was projected on the IOL through the mask pattern in reduced size in the presence of water in order to be hydrophilic. With the photochemical reaction, the OH groups were substituted at the part exposed. The fibrin adsorption test of the modified IOL surface was carried out with FT-IR; which revealed that the fibrin-sticking rate of the treated sample has decreased by 23% compared with that of the non-treated sample. As a result, the fibrin-free IOL has been made by modifying the surface of the IOL to have the micro domain structures of the hydrophilic and hydrophobic groups that are arrayed alternately. In conclusion, the ideal intraocular lens has been demonstrated.
Schmidinger, G; Pemp, B; Werner, L
2013-11-01
A patient with endothelial dystrophy was treated with Descemet stripping automated endothelial keratoplasty (DSAEK) combined with cataract extraction and implantation of a hydrophilic intraocular lens (IOL, Lentis-L312, Oculentis) but visual acuity dropped from 0.15 logMAR to 0.52 logMAR 18 months later due to calcification of the IOL. With new methods of lamellar corneal transplantation being used more frequently the number of necessary anterior chamber tamponades with air/gas are increasing. In cataract cases in which a gas tamponade and transplantation might be necessary later on (cornea guttata), hydrophilic IOLs should be avoided.
Bilateral spontaneous crystalline lens dislocation to the anterior chamber: a case report.
Jovanović, Milos
2013-01-01
There are various reasons for the lens dislocation. Spontaneous dislocation of a clear lens is extremely rare, especially its dislocation to the anterior chamber. The author presents a case of spontaneous clear lens dislocation to the anterior chamber in both eyes in a patient without the history of any trauma. Dislocation occurred spontaneously, first in the left eye, along with a sudden decrease of vision. The ophthalmologist found a clear lens in the anterior chamber, without any sign of an elevated intraocular pressure, as should have been expected. The dislocated lens was removed surgically (intracapsular extraction) with the preventive basal iridectomy. Two years later, the same happened in the right eye: clear lens moved spontaneously to the anterior chamber, with a decrease of vision, but again without any rise of intraocular pressure and/or any pain. Intracapsular extraction of the lens with basal iridectomy was done again. The presented case demonstrates that spontaneous dislocation of the transparent lens to the eye anterior chamber can occur in both eyes at different time intervals. We suggest the removal of dislocated lens in the anterior chamber by the intracapsular extraction.
Morizane, Yuki; Shiode, Yusuke; Hirano, Masayuki; Doi, Shinichiro; Toshima, Shinji; Fujiwara, Atsushi; Shiraga, Fumio
2017-01-01
Purpose To investigate the tilt and decentration of the crystalline lens and the intraocular lens (IOL) relative to the corneal topographic axis using anterior segment ocular coherence tomography (AS-OCT). Methods A sample set of 100 eyes from 49 subjects (41 eyes with crystalline lenses and 59 eyes with IOLs) were imaged using second generation AS-OCT (CASIA2, TOMEY) in June and July 2016 at Okayama University. Both mydriatic and non-mydriatic images were obtained, and the tilt and decentration of the crystalline lens and the IOL were quantified. The effects of pupil dilation on measurements were also assessed. Results The crystalline lens showed an average tilt of 5.15° towards the inferotemporal direction relative to the corneal topographic axis under non-mydriatic conditions and 5.25° under mydriatic conditions. Additionally, an average decentration of 0.11 mm towards the temporal direction was observed under non-mydriatic conditions and 0.08 mm under mydriatic conditions. The average tilt for the IOL was 4.31° towards the inferotemporal direction relative to the corneal topographic axis under non-mydriatic conditions and 4.65° in the same direction under mydriatic conditions. The average decentration was 0.05 mm towards the temporal direction under non-mydriatic conditions and 0.08 mm in the same direction under mydriatic conditions. A strong correlation was found between the average tilt and decentration values of the crystalline lens and the IOL under both non-mydriatic and mydriatic conditions (all Spearman correlation coefficients, r ≥ 0.800; all P < 0.001). Conclusion When measured using second generation AS-OCT, both the crystalline lens and the IOL showed an average tilt of 4–6° toward the inferotemporal direction relative to the corneal topographic axis and an average decentration of less than 0.12 mm towards the temporal direction. These results were not influenced by pupil dilation and they showed good repeatability. PMID:28863141
Kimura, Shuhei; Morizane, Yuki; Shiode, Yusuke; Hirano, Masayuki; Doi, Shinichiro; Toshima, Shinji; Fujiwara, Atsushi; Shiraga, Fumio
2017-01-01
To investigate the tilt and decentration of the crystalline lens and the intraocular lens (IOL) relative to the corneal topographic axis using anterior segment ocular coherence tomography (AS-OCT). A sample set of 100 eyes from 49 subjects (41 eyes with crystalline lenses and 59 eyes with IOLs) were imaged using second generation AS-OCT (CASIA2, TOMEY) in June and July 2016 at Okayama University. Both mydriatic and non-mydriatic images were obtained, and the tilt and decentration of the crystalline lens and the IOL were quantified. The effects of pupil dilation on measurements were also assessed. The crystalline lens showed an average tilt of 5.15° towards the inferotemporal direction relative to the corneal topographic axis under non-mydriatic conditions and 5.25° under mydriatic conditions. Additionally, an average decentration of 0.11 mm towards the temporal direction was observed under non-mydriatic conditions and 0.08 mm under mydriatic conditions. The average tilt for the IOL was 4.31° towards the inferotemporal direction relative to the corneal topographic axis under non-mydriatic conditions and 4.65° in the same direction under mydriatic conditions. The average decentration was 0.05 mm towards the temporal direction under non-mydriatic conditions and 0.08 mm in the same direction under mydriatic conditions. A strong correlation was found between the average tilt and decentration values of the crystalline lens and the IOL under both non-mydriatic and mydriatic conditions (all Spearman correlation coefficients, r ≥ 0.800; all P < 0.001). When measured using second generation AS-OCT, both the crystalline lens and the IOL showed an average tilt of 4-6° toward the inferotemporal direction relative to the corneal topographic axis and an average decentration of less than 0.12 mm towards the temporal direction. These results were not influenced by pupil dilation and they showed good repeatability.
Ravani, Raghav; Chawla, Rohan; Azad, Shorya Vardhan; Gupta, Yogita; Kumar, Vinod; Kumar, Atul
2018-01-01
Purpose: The objective of this study is to describe the removal of retained intraocular foreign body (RIOFB) by bimanual pars plana vitrectomy through midline sclerotomy in phakic patients. Technique: Four eyes with RIOFB and clear lens underwent microincision vitrectomy surgery. A chandelier illumination was placed through one of the existing ports. The foreign body (FB) was localized by direct visualization (intravitreal) or indentation (pars plana), stabilized using an intraocular magnet/FB forceps introduced through a midline sclerotomy and freed of vitreous from all sides using a vitrectomy cutter through the other port bimanually, reoriented along their long axis and extracted through the midline sclerotomy. Results: All four FBs were removed successfully without slippage or damage to the clear lens. Conclusion: Chandelier illumination-assisted removal of FB through midline sclerotomy helps in easier localization, stabilization and removal, avoiding lens touch even in anteriorly located FBs such as at pars plana. PMID:29676316
Lin, Siying; Gupta, Bhaskar; Rossiter, Jonathan
2016-02-01
Minimally invasive glaucoma surgery is a developing area that has the potential to replace traditional glaucoma surgery, with its known risk profile, but at present there are no randomised controlled data to validate its use. We report on a case where sequential bilateral combined ab interno trabeculotomy and lens extraction surgery was performed on a 45-year-old woman with combined uveitic and chronic narrow angle raised intraocular pressure. Maximal medical management alone could not control the intraocular pressure. At 12-month follow-up, the patient had achieved stable intraocular pressure in both eyes on a combination of topical ocular antiglaucomatous and steroid therapies. This case demonstrates the effectiveness of trabecular meshwork ablation via ab interno trabeculotomy in a case of complex mixed mechanism glaucoma. 2016 BMJ Publishing Group Ltd.
Lin, Siying; Gupta, Bhaskar; Rossiter, Jonathan
2016-01-01
Minimally invasive glaucoma surgery is a developing area that has the potential to replace traditional glaucoma surgery, with its known risk profile, but at present there are no randomised controlled data to validate its use. We report on a case where sequential bilateral combined ab interno trabeculotomy and lens extraction surgery was performed on a 45-year-old woman with combined uveitic and chronic narrow angle raised intraocular pressure. Maximal medical management alone could not control the intraocular pressure. At 12-month follow-up, the patient had achieved stable intraocular pressure in both eyes on a combination of topical ocular antiglaucomatous and steroid therapies. This case demonstrates the effectiveness of trabecular meshwork ablation via ab interno trabeculotomy in a case of complex mixed mechanism glaucoma. PMID:26833953
Toric Intraocular Lens Outcomes in Patients With Glaucoma.
Brown, Reay H; Zhong, Le; Bozeman, Caroline W; Lynch, Mary G
2015-06-01
To report the outcomes of toric intraocular lens implantation in patients with glaucoma and corneal astigmatism. One hundred twenty-six eyes of 87 patients with glaucoma and corneal astigmatism that underwent cataract surgery with an AcrySof toric intraocular lens (Alcon Laboratories, Inc., Fort Worth, TX) implant were selected for this single-center, retrospective case series. Corrected distance visual acuity, intraocular pressure, and refractive astigmatism were measured in each eye preoperatively and postoperatively. Uncorrected distance visual acuity and toric alignment were measured postoperatively. The uncorrected distance visual acuity was 0.04 ± 0.08 logMAR (20/22 Snellen) for all eyes. Ninety-eight percent of all eyes achieved an uncorrected distance visual acuity of 20/40 or better, with 76% achieving 20/25 or better and 47% achieving 20/20. The corrected distance visual acuity for all eyes was 0.01 ± 0.03 logMAR (20/20.5 Snellen) postoperatively. The refractive cylinder improved from 1.47 ± 1.10 diopters preoperatively to 0.31 ± 0.37 diopters postoperatively. The residual refractive cylinder was 1.00 diopter or less in 97% of eyes, 0.75 diopters or less in 90% of eyes, and 0.50 diopters or less in 83% of eyes. Mean misalignment was 4.4° ± 5.1°. Intraocular pressure decreased by a mean of 2.3 ± 3.3 mm Hg following the surgery. Toric intraocular lenses can reliably reduce astigmatism and improve uncorrected vision in eyes with cataract and glaucoma. Copyright 2015, SLACK Incorporated.
Johnstone, Nancy; Ward, Daniel A
2005-01-01
The objective of this retrospective study was to report the incidence of posterior capsule disruption during routine phacoemulsification and to document the postoperative outcomes and complications in eyes with posterior capsule disruption compared with eyes with intact posterior capsules. Records of 143 dogs (244 eyes) were reviewed. Data collected included whether the posterior capsule was disrupted, whether the disruption was planned or accidental, whether an intraocular lens was implanted, and visual outcome. Records were reviewed for postoperative complications. Intraocular lens implantation rates, complication rates, and visual outcomes were compared between intact and disrupted posterior capsule groups using Chi-square analyses. The posterior capsule was disrupted in 33/244 eyes (14%). Planned capsulotomies accounted for 36% of the disruptions. Intraocular lenses were implanted in 76% of eyes without a disruption of the posterior capsule and in 31% of eyes with a posterior capsule disruption. Intraocular lenses were more likely to be implanted in eyes with a planned disruption of the posterior capsule (7/12; 58%) than in eyes with an accidental disruption (3/20; 15%). There were no significant differences in postoperative complications or visual outcome between eyes with posterior capsule disruption and those without. The most significant complication of posterior capsule disruption during phacoemulsification is the inability to implant an intraocular lens. Intraocular lenses are more likely to be placed in eyes with intentional disruptions of the posterior capsule than those with accidental ruptures.
The prevalence of artificial lens implants in the civil airman population.
DOT National Transportation Integrated Search
1992-03-01
The use of artificial lens implants to correct for aphakia has become increasingly prevalent in the United States. This study analyzes the distribution of intraocular lens (IOL) implants in the civil airman population by type (unilateral bilateral), ...
Gunenc, Uzeyir; Kocak, Nilufer; Ozturk, A Taylan; Arikan, Gul
2014-08-01
We describe a technique to manage late spontaneous intraocular lens (IOL) and capsular tension ring (CTR) dislocation within the intact capsular bag. The subluxated IOL and CTR complex can be positioned in a closed chamber and fixed to the pars plana at both 3 and 9 o'clock quadrants with the presented ab externo direct scleral suturation technique which provides an easy, safe and effective surgical option for such cases.
Ultrastructural evaluation of explanted opacified Hydroview (H60M) intraocular lenses
Cartwright, Nathaniel E Knox; Mayer, Eric J; McDonald, Brendan M; Skinner, Andrew; Salter, Chris J; Tole, Derek M; Sparrow, John M; Dick, Andrew D; Group, The Bristol IOL Study; Ferguson, David J P
2007-01-01
Aim To describe the ultrastructural appearance of explanted opacified Hydroview H60M intraocular lenses. Methods 14 explanted lenses were examined by scanning electron microscopy, and their appearance compared with a non‐implanted H60M lens from the same time period. Wavelength‐dispersive x ray spectroscopy (WDX) was performed on two opacified lenses. Results Subsurface deposits were seen in all explanted opacified lenses. These deposits broke only onto the surface of more densely opacified lenses. WDX confirmed that the deposits contained both calcium and phosphorous, consistent with their being calcium apatite. Conclusion These findings challenge the widely accepted opinion that H60M intraocular lens opacification begins on the surface of the optic. PMID:16987894
2012-01-01
Background The implementation of capitated payment has driven medical institutions through developing balance billing for medical services. By exploring the patients’ decision-making factors on different self-pay items, a reference for the pricing and sales strategy for the related products can be formed. The major purposes of this study were to analyze the determinants of preoperative selection and postoperative satisfaction with implantation of different types of intraocular lenses in cataract surgery. Methods This cross-sectional study consisted of 127 patients that were 50 years of age and older, and who had phacoemulsification with intraocular lens implantation in both eyes. Data were collected by using a structured questionnaire. The following parameters were measured: access to medical care, attitude towards receiving medical products at one’s own expense, overall patient satisfaction and postoperative visual clarity. Results The results showed that the patient’s gender, educational level and economic status influenced the type of intraocular lens chosen. Patients in the insurance group cared about access to medical care, and patients in the balance billing group cared about product differentiation. ANOVA results showed no statistically significant differences in the overall satisfaction of the patients among the groups with different types of intraocular lenses. Patients that received cataract surgery with implantation of multifocal intraocular lenses had better vision when trying to view smaller objects and when looking at objects under strong light. Conclusions Manufacturers should increase the number of differences between their products, and health care providers can then recommend the appropriate intraocular lens in accordance with the needs or demands of their patients, and also by keeping in mind the financial constraints of their patients. PMID:23107001
Wei, Ching-Kuo; Wang, Shun-Mu; Lin, Jen-Chieh
2012-10-29
The implementation of capitated payment has driven medical institutions through developing balance billing for medical services. By exploring the patients' decision-making factors on different self-pay items, a reference for the pricing and sales strategy for the related products can be formed. The major purposes of this study were to analyze the determinants of preoperative selection and postoperative satisfaction with implantation of different types of intraocular lenses in cataract surgery. This cross-sectional study consisted of 127 patients that were 50 years of age and older, and who had phacoemulsification with intraocular lens implantation in both eyes. Data were collected by using a structured questionnaire. The following parameters were measured: access to medical care, attitude towards receiving medical products at one's own expense, overall patient satisfaction and postoperative visual clarity. The results showed that the patient's gender, educational level and economic status influenced the type of intraocular lens chosen. Patients in the insurance group cared about access to medical care, and patients in the balance billing group cared about product differentiation. ANOVA results showed no statistically significant differences in the overall satisfaction of the patients among the groups with different types of intraocular lenses. Patients that received cataract surgery with implantation of multifocal intraocular lenses had better vision when trying to view smaller objects and when looking at objects under strong light. Manufacturers should increase the number of differences between their products, and health care providers can then recommend the appropriate intraocular lens in accordance with the needs or demands of their patients, and also by keeping in mind the financial constraints of their patients.
Early opacification and subsequent in vivo clearing of a silicone intraocular lens.
Nikrooyan, Idean; Anderson, Justin E
2011-09-01
To report a case of early opacification and spontaneous in vivo clearing of a silicone intraocular lens (IOL). A 79-year-old women underwent uncomplicated cataract extraction and subsequent implantation of a +21.5 D AMO Z9002 (Abbott Medical Optics, Santa Ana, CA) silicone lens. On postoperative day 1, the patient presented with a translucent, milky white appearing, diffuse IOL opacification. On postoperative day 8, the IOL periphery had cleared, but a full thickness haze persisted in the central portion of the optic. By postoperative day 14, the IOL had cleared. To date, the lens has remained clear. One possible mechanism might be exposure to industrial chemicals; however, the manufacturer reports no other similar lens opacities from this manufacturing batch of IOLs. We recommend that surgeons who implant or have implanted an AMO Z9002 silicone IOL and observe similar findings follow the patient closely for resolution of the haze.
NASA Astrophysics Data System (ADS)
Lin, Shan-Yang; Chen, Ko-Hwa; Lin, Chih-Cheng; Cheng, Wen-Ting; Li, Mei-Jane
2010-10-01
This preliminary report was attempted to compare the chemical components of mineral deposits on the surfaces of an opacified intraocular lens (IOL) and a calcified senile cataractous lens (SCL) by vibrational spectral diagnosis. An opacified intraocular lens (IOL) was obtained from a 65-year-old male patient who had a significant decrease in visual acuity 2-years after an ocular IOL implantation. Another SCL with grayish white calcified plaque on the subcapsular cortex was isolated from a 79-year-old male patient with complicated cataract after cataract surgery. Optical light microscope was used to observe both samples and gross pictures were taken. Fourier transform infrared (FT-IR) and Raman microspectroscopic techniques were employed to analyze the calcified deposits. The curve-fitting algorithm using the Gaussian function was also used to quantitatively estimate the chemical components in each deposit. The preliminary results of spectral diagnosis indicate that the opacified IOL mainly consisted of the poorly crystalline, immature non-stoichiometric hydroxyapatite (HA) with higher content of type B carbonated apatites. However, the calcified plaque deposited on the SCL was comprised of a mature crystalline stoichiometric HA having higher contents of type A and type B carbonate apatites. More case studies should be examined in future.
Helium-ion-induced human cataractogenesis
NASA Technical Reports Server (NTRS)
Blakely, E. A.; Daftari, I. K.; Meecham, W. J.; Alonso, L. C.; Collier, J. M.; Kroll, S. M.; Gillette, E. L.; Lee, A. C.; Lett, J. T.; Cox, A. B.
1994-01-01
Retrospective and ongoing analyses of clinical records from 347 primary intraocular melanoman patients treated with helium ions at Lawrence Berkeley Laboratory (LBL) will allow examination of the exposure-response data for human cataract; which is a complication of the therapy from incidental exposure of the lens. Direct particle beam traversal of at least a portion of the lens usually is unavoidable in treatment of posterior intraocular tumors. The precise treatment planned for each patient permits quantitative assessment of the lenticular dose and its radiation quality. We are reporting our preliminary results on the development of helium-ion-induced lens opacifications and cataracts in 54 of these patients who had 10% or less of their lens in the treatment field. We believe these studies will be relevant to estimating the human risk for cataract in space flight.
Mechanical properties of intra-ocular lenses
NASA Astrophysics Data System (ADS)
Ehrmann, Klaus; Kim, Eon; Parel, Jean-Marie
2008-02-01
Cataract surgery usually involves the replacement of the natural crystalline lens with a rigid or foldable intraocular lens to restore clear vision for the patient. While great efforts have been placed on optimising the shape and optical characteristics of IOLs, little is know about the mechanical properties of these devices and how they interact with the capsular bag once implanted. Mechanical properties measurements were performed on 8 of the most commonly implanted IOLs using a custom build micro tensometer. Measurement data will be presented for the stiffness of the haptic elements, the buckling resistance of foldable IOLs, the dynamic behaviour of the different lens materials and the axial compressibility. The biggest difference between the lens types was found between one-piece and 3-piece lenses with respect to the flexibility of the haptic elements
INTRAOCULAR LENS SCAFFOLD TO PREVENT INTRAOCULAR FOREIGN BODY SLIPPAGE.
Agarwal, Amar; Ashok Kumar, Dhivya; Agarwal, Athiya
2017-01-01
To report the application of intraocular lens (IOL) scaffold technique in intraocular foreign body (IOFB) removal. Patient with IOFB in posterior segment is included. The IOFB is retrieved from the posterior segment (pars plana vitrectomy and exteriorization of the IOFB from the retinal surface using an intravitreal forceps via the posterior capsulotomy) and placed on the iris. A three-piece posterior chamber IOL is placed in the sulcus via the clear corneal incision. IOFB is then removed from the anterior chamber over the IOL by forceps. Metallic IOFB of 4 mm × 3 mm has been retrieved by IOL scaffold technique after rescuing it from the posterior segment. There has been no drop or slip of IOFB in the vitreous during removal. Posterior chamber IOL served as scaffold during IOFB removal from anterior chamber. The IOL scaffold maneuver has shown to prevent slippage by acting as a barrier between the IOFB and the vitreous.
Almond, M Camille; Wu, Michael C; Chen, Philip P
2009-12-01
A 55-year-old man had phacoemulsification and implantation of a 3-piece acrylic intraocular lens (IOL) (AcrySof MA60AC) in the right eye. One month postoperatively, the intraocular pressure (IOP) was 48 mm Hg and peripheral transillumination defects were noted in the iris circumferentially, with the IOL optic edge visible as a silhouette. Gonioscopy showed dense pigmentation of the trabecular meshwork in the right eye, but in the left eye, only mild trabecular meshwork pigment was seen, along with a concave peripheral iris insertion. At 21 months, the right eye required 3 medications for IOP control. While pigment dispersion has been widely reported after placement of 1-piece acrylic IOLs in the ciliary sulcus, we conclude that in susceptible individuals with a concave peripheral iris insertion, pigment dispersion can occur with sulcus placement of a 3-piece acrylic model despite its thinner optic and angulated haptics.
Cataract and keratoconus: minimizing complications in intraocular lens calculations.
Bozorg, Sara; Pineda, Roberto
2014-01-01
Patients with both cataract and keratoconus present unique challenges for the surgeon. Accurate keratometry (K) and axial length (AL) readings may be impossible, and uncertainty is introduced when estimating the corneal power for intraocular lens (IOL) selection. Different options on how to choose an IOL and how to manage irregular astigmatism of a keratoconic patient with cataract have been proposed and are reviewed. The stage of keratoconus and the history of the patient are both critical in determining the strategy used in treatment of cataracts.
Neodymium: YAG lasers. An FDA report.
Stark, W J; Worthen, D; Holladay, J T; Murray, G
1985-02-01
Analysis of data from four neodymium:YAG laser manufacturers submitted to the Food and Drug Administration (FDA) on over 17,000 cases indicate the procedure is safe and effective for cutting opaque posterior lens capsules. A successful opening in the pupillary membrane was achieved in 98% of the cases, and vision improved in 84% of the cases. Clinically significant risks include: a rise in intraocular pressure two to four hours after treatment, damage to the intraocular lens, and rupture of the anterior hyaloid face.
Intraocular Lens Use in an Astronaut During Long Duration Spaceflight.
Mader, Thomas H; Gibson, C Robert; Schmid, Josef F; Lipsky, William; Sargsyan, Ashot E; Garcia, Kathleen; Williams, Jeffrey N
2018-01-01
The purpose of this paper is to report the first use of an intraocular lens (IOL) in an astronaut during long duration spaceflight (LDSF). An astronaut developed a unilateral cataract and underwent phacoemulsification with insertion of an acrylic IOL. Approximately 15 mo later he flew on a Soyuz spacecraft to the International Space Station (ISS), where he successfully completed a 6-mo mission. Ocular examination, including ultrasound (US), was performed before, during, and after his mission and he was questioned regarding visual changes during each portion of his flight. We documented no change in IOL position during his space mission. This astronaut reported excellent and stable vision during liftoff, entry into microgravity (MG), 6 mo on the ISS, descent, and landing. Our results suggest that modern IOLs are stable, effective, and well tolerated during LDSF.Mader TH, Gibson CR, Schmid JF, Lipsky W, Sargsyan AE, Garcia K, Williams JN. Intraocular lens use in an astronaut during long duration spaceflight. Aerosp Med Hum Perform. 2018; 89(1):63-65.
Engineering hurdles in contact and intraocular lens lathe design: the view ahead
NASA Astrophysics Data System (ADS)
Bradley, Norman D.; Keller, John R.; Ball, Gary A.
1994-05-01
Current trends in and intraocular lens design suggest ever- increasing demand for aspheric lens geometries - multisurface and/or toric surfaces - in a variety of new materials. As computer numeric controls (CNC) lathes and mills continue to evolve with he ophthalmic market, engineering hurdles present themselves to designers: Can hardware based upon single-point diamond turning accommodate the demands of software-driven designs? What are the limits of CNC resolution and repeatability in high-throughput production? What are the controlling factors in lathed, polish-free surface production? Emerging technologies in the lathed biomedical optics field are discussed along with their limitations, including refined diamond tooling, vibrational control, automation, and advanced motion control systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
... who are well adapted to intraocular lens implant or contact lens correction, visual field examinations.... For aphakic individuals not well adapted to contact lens correction or pseudophakic individuals not... meridians 221/2 degrees apart for each eye and indicate the Goldmann equivalent used. See Table III for the...
Code of Federal Regulations, 2010 CFR
2010-07-01
... who are well adapted to intraocular lens implant or contact lens correction, visual field examinations.... For aphakic individuals not well adapted to contact lens correction or pseudophakic individuals not... meridians 221/2 degrees apart for each eye and indicate the Goldmann equivalent used. See Table III for the...
Gobin, Laure; Tassignon, Marie-José; Mathysen, Danny
2011-06-01
To propose a method of calculating the power of the 1-sided posterior chamber toric bag-in-the-lens (BIL) intraocular lens (IOL) and propose a misalignment nomogram to calculate the postoperative rotational misalignment or predict the effect of preoperative existing irregular corneal astigmatism. Antwerp University Hospital, Department of Ophthalmology, Antwerp, Belgium. Cohort study. The new IOL calculation formula uses the steepest corneal meridian and flattest corneal meridian separately (regular spherical IOL formula) followed by a customized A-constant approach based on the changes in the IOL principal plane depending on the spherical and cylindrical powers (thickness) of the IOL. The calculation of the remaining astigmatism (power and axis) in cases of postoperative rotational misalignment resulted in a nomogram that can also be used to predict the degree of tolerance for irregular corneal astigmatism correction at the lenticular plane. The calculation is performed using a worksheet. Because 10 degrees of misalignment would result in 35% refractive inaccuracy, it is the maximum acceptable corneal astigmatic irregularity for correction at the lenticular plane. Calculation of spherocylindrical power is specific to each toric IOL. Because the surgeon must fully understand the optical properties of the toric IOL that is going to be implanted, a comprehensive outline of a new calculation method specific to the toric BIL IOL is proposed. Primary rotational misalignment of the toric BIL IOL can be fine tuned postoperatively. Drs. Gobin and Mathysen have no financial or proprietary interest in any material or method mentioned. Additional disclosures are found in the footnotes. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Majima, K
1998-01-01
To examine the morphological changes of lens epithelial cells (LECs) occurring directly beneath and at regions contacting various intraocular lens (IOL) optic materials, human LECs were cultured on human anterior lens capsules and were further incubated upon placing above the cells lens optics made of polymethylmethacrylate, silicone, and soft acrylic material. Observations as to the morphological changes of LECs under phase-contrast microscope and scanning electron microscope were performed on the 14th day of incubation. Gatherings of LECs were observed at regions contacting the soft acrylic material under phase-contrast microscope, and gatherings of LECs were observed accurately at the same regions mentioned above under scanning electron microscope. On the other hand, LECs in contact with two other optic materials did not show morphological changes. The results suggest that LECs attached to and proliferated on not only the anterior lens capsules but also the soft acrylic IOL optics. The model used in this study may be useful in studying the relationship between cellular movement of LECs and IOL optic material.
Motor skills of children with unilateral visual impairment in the Infant Aphakia Treatment Study.
Celano, Marianne; Hartmann, E Eugenie; DuBois, Lindreth G; Drews-Botsch, Carolyn
2016-02-01
To assess motor functioning in children aged 4 years 6 months enrolled in the Infant Aphakia Treatment Study, and to determine contributions of visual acuity and stereopsis to measured motor skills. One hundred and four children (53% female) with unilateral aphakia randomized to intraocular lens or contact lens treatment were evaluated at 4 years 6 months (age range 4y 6mo-4y 11mo) for monocular recognition visual acuity, motor skills, and stereopsis by a traveling examiner masked to treatment condition. Motor skills were assessed with the Movement Assessment Battery for Children--Second Edition (MABC-2). Visual acuity was operationalized as log10 of the minimum angle of resolution (logMAR) value for treated eye, best logMAR value for either eye, and intraocular logMAR difference. Student's t-tests showed no significant differences in MABC-2 scores between the intraocular lens and contact lens groups. The mean total score was low (6.43; 18th centile) compared with the normative reference group. Motor functioning was not related to visual acuity in the treated eye or to intraocular logMAR difference, but was predicted in a regression model by the better visual acuity of either eye (usually the fellow eye), even after accounting for the influence of age at surgery, examiner, orthotropic ocular alignment, and stereopsis. Children with unilateral congenital cataract may have delayed motor functioning at 4 years 6 months, which may adversely affect their social and academic functioning. © 2015 Mac Keith Press.
Stuhr, Charles M; Schilke, Hillary K; Forte, Christina
2009-01-01
To evaluate the postoperative results of lensectomy and sulcus intraocular lens fixation (SIOLF) via an ab interno approach in dogs with progressive lens subluxation or early luxation. Retrospective study. Twenty eyes from 19 dogs presented to the Animal Eye Clinic for lens luxation or subluxation between 1999 and 2006. Medical records were reviewed to evaluate preoperative lens position, vision status, intraocular pressure (IOP), and whether surgery was performed on an emergent or elective nature. Lensectomy and SIOLF were performed and postoperative status including vision, glaucoma, and retinal detachment was assessed. Average age was 8.6 years (range 4-14 years) and 55% (11/20) were terriers. Patients were followed a mean of 29.2 months (range 1-92 months) after surgery. Retinal detachment or secondary glaucoma was observed in 1 of 20 (5%) and 5 of 20 (20%) eyes, respectively, with 1 of 20 (5%) exhibiting both. Mean preoperative IOP was 16 mmHg and preoperative lens position was equally divided between luxated and subluxated lenses. Surgery was performed more frequently as an elective procedure (18/20; 90%) due to normalized IOP vs. an emergency procedure (2/20; 10%). Vision was retained in 70% (14/20) of eyes with a mean time to vision loss of 41 months in the remaining eyes due to glaucoma, retinal detachment, or retinal degeneration. Complications of glaucoma and retinal detachment after SIOLF in this study were less when compared with previously reported incidence rates in the literature for lensectomy alone which may reflect improved patient selection.
Yeung, Ling; Wang, Nan-Kai; Wu, Wei-Chi; Chen, Kuan-Jen
2018-04-23
To evaluate the safety and efficacy of combined 23-gauge transconjunctival pars plana vitrectomy and scleral fixation of intraocular lens (IOL) without conjunctival dissection. A retrospective study in Chang Gung Memorial Hospital, Keelung and Taoyuan, Taiwan. Patients receiving combined 23-gauge transconjunctival pars plana vitrectomy and scleral fixation of IOL without conjunctival dissection were enrolled. The ocular findings, causes of lens complication, surgical procedures, type of IOL used, and complications were documented. We included 40 eyes from 39 patients (27 male, 12 female) with a mean age of 59.5 [standard deviation (±) 14.8] years old. The mean follow-up duration was 6.8 ± 5.4 months. The cause of lens complications was ocular trauma in 24 (60%) eyes, cataract surgery complications in 11 (28%) eyes, and spontaneous subluxation of crystalline lens in 5 (13%) eyes. The overall best corrected visual acuity (BCVA) (logMAR) improved from 1.359 ± 0.735 to 0.514 ± 0.582 (p < 0.001). The BCVA also improved significantly in each group with different causes of lens complications. Preoperative BCVA was the only factor associated with the postoperative visual outcome (p = 0.008). Most surgery-related complications were self-limited, including mild vitreous hemorrhage (5%), microhyphema (5%), transient elevated intraocular pressure (3%), and transient hypotony (3%). Cystoid macular edema and IOL decentration was found in 3 (8%) eyes and 1 (3%) eye respectively. Combined 23-gauge transconjunctival vitrectomy and scleral fixation of IOL without conjunctival dissection is effective and safe in managing a wide variety of lens complications, with good postoperative comfort and visual recovery. Retrospective study, not applicable.
High Refractive Index Polysiloxane as Injectable, In Situ Curable Accommodating Intraocular Lens
Hao, Xiaojuan; Jeffery, Justine L.; Le, Tam P.T.; McFarland, Gail; Johnson, Graham; Mulder, Roger J.; Garrett, Qian; Manns, Fabrice; Nankivil, Derek; Arrieta, Esdras; Ho, Arthur; Parel, Jean-Marie; Hughes, Timothy C.
2012-01-01
Functionalised siloxane macromonomers, with properties designed for application as an injectable, in situ curable accommodating intraocular lens (A-IOL), were prepared via reequilibration of a phenyl group-containing polysiloxane of very high molecular weight with octamethylcyclotetrasiloxane (D4) and 2,4,6,8-tetra(n-propyl-3-methacrylate)-2,4,6,8-tetramethylcyclotetrasiloxane (D4AM) in toluene using trifluoromethanesulfonic acid as a catalyst. Hexaethyldisiloxane was used as an end group to control the molecular weight of the polymer. The generated polymers had a consistency suitable for injection into the empty lens capsule. The polymers contained a low ratio of polymerisable groups so that, in the presence of a photo-initiator, they could be cured on demand in situ within 5 minutes under irradiation of blue light to form an intraocular lens within the lens capsule. All resulting polysiloxane soft gels had a low elastic modulus and thus should be able to restore accommodation. The pre-cure viscosity and post-cure modulus of the generated polysiloxanes were controlled by the end group and D4AM concentrations respectively in the re-equilibration reactions. The refractive index could be precisely controlled by adjusting the aromatic ratio in the polymer to suit such application as an artificial lens. Lens stretching experiments with both human and non-human primate cadaver lenses of different ages refilled with polysiloxane polymers provided a significant increase in amplitude of accommodation (up to 4 D more than that of the respective natural lens). Both in vitro cytotoxicity study using L929 cell lines and in vivo biocompatibility study in rabbit models demonstrated the non-cytotoxicity and ocular biocompatibility of the polymer. PMID:22594975
Topical anesthesia for transpupillary silicone oil removal combined with cataract surgery.
Jonas, Jost B; Hugger, Philipp; Sauder, Gangolf
2005-09-01
To assess safety of topical anesthesia for transpupillary silicone oil removal in combination with cataract surgery. Department of Ophthalmology Mannheim, University of Heidelberg, Mannheim, Germany. The clinical interventional study included 37 consecutive patients having transpupillary silicone oil removal combined with cataract surgery. Without exception, surgery was carried out in topical anesthesia for all patients. During the study period, there were no patients having transpupillary silicone oil removal in another type of local anesthesia than topical anesthesia. Topical anesthesia was achieved with oxybuprocaine 0.4% eyedrops installed 4 to 5 times prior to surgery. Cataract surgery was performed using the clear cornea technique with implantation of a foldable intraocular posterior chamber lens. Silicone oil was released through a planned posterior capsulotomy during cataract surgery prior to implantation of the intraocular lens (IOL). For all patients, surgery could be carried out in topical anesthesia without switching to peribulbar or any other type of anesthesia. None of the patients complained about severe pain intraoperatively or postoperatively. No severe complications such as expulsive hemorrhage, luxation of the IOL, or iris incarceration were encountered in any of the surgeries. Transpupillary silicone oil through a planned posterior capsulotomy during cataract surgery may be performed in topical surgery.
Le Loir, M; Cochener, B
2012-06-01
To assess efficacy, stability and safety of posterior chamber phakic intraocular lens implantation with STAAR Visian ICL for correction of high ametropia, with a mean follow-up of 5 years (3.5-10 years). Ninety eyes of 53 highly ametropic patients (45 myopia, ten hyperopia and 35 with mixed astigmatism) were included in a retrospective single-surgeon study, using primarily the V4 ICL model (87 eyes). We studied pre- and postoperative refractive efficacy, endothelial cell density, crystalline lens opacification and intraocular clearances within the various compartments of the eye. Mean uncorrected visual acuity was 0.77 at the 12th postoperative month; 17 of 90 eyes required adjunctive photoablation for residual astigmatism. Forty-eight percent of eyes gained at least one line of best corrected visual acuity. After implantation, the decrease in endothelial cell density remained stable at 0.69%/year, and 91% of eyes showed no opacification of the crystalline lens. Mean endothelium-ICL and ICL-crystalline lens distances were 2.41 mm and 0.52 mm respectively. Overall patient satisfaction achieved was 96% at 36 months postoperatively. These results demonstrate efficacy, stability and safety of the ICL V4 phakic IOL for the correction of high ametropia. Long-term follow-up did not show a significant increase in cataract formation in implanted eyes. Copyright © 2012. Published by Elsevier Masson SAS.
42 CFR 402.1 - Basis and scope.
Code of Federal Regulations, 2011 CFR
2011-10-01
... willfully presents, or causes to be presented, a bill or request for payment for an intraocular lens... acquiring the class of lens involved. (3) Section 1833(q)(2)(B)—Any entity that knowingly and willfully...
Kohnen, Thomas; Kook, Daniel
2009-08-01
We describe 2 cases of pigment dispersion syndrome (PDS) after uneventful phacoemulsification and implantation of a posterior chamber single-piece intraocular lens (IOL) with a sharp-edge design. In both cases, several days after IOL implantation, marked pigment dispersion was seen on the iris and in the trabecular meshwork, associated with an elevation in intraocular pressure (IOP). Thorough examination showed that the implanted IOL was in the ciliary sulcus. After surgical repositioning of both IOLs in the capsular bag, the pigment dispersion regressed and the IOP returned to normal limits. The 2 cases suggest that particularly in PDS patients, an IOL with an anterior sharp-edge design should be implanted in the capsular bag. Implantation in the ciliary sulcus should be avoided.
Forces on intraocular lens haptics induced by capsular fibrosis. An experimental study.
Guthoff, R; Abramo, F; Draeger, J; Chumbley, L C; Lang, G K; Neumann, W
1990-01-01
Electronic dynamometry measurements, performed upon intraocular lens (IOL) haptics of prototype one-piece three-loop silicone lenses, accurately defined the relationships between elastic force and haptic displacement. Lens implantations in the capsular bag of dogs (loop span equal to capsular bag diameter, loops underformed immediately after the operation) were evaluated macrophotographically 5-8 months postoperatively. The highly constant elastic property of silicon rubber permitted quantitative correlation of subsequent in vivo haptic displacement with the resultant force vectors responsible for tissue contraction. The lens optics were well centered in 17 (85%) and slightly offcenter in 3 (15%) of 20 implanted eyes. Of the 60 supporting loops, 28 could be visualized sufficiently well to permit reliable haptic measurement. Of these 28, 20 (71%) were clearly displaced, ranging from 0.45 mm away from to 1.4 mm towards the lens' optic center. These extremes represented resultant vector forces of 0.20 and 1.23 mN respectively. Quantitative vector analysis permits better understanding of IOL-capsular interactions.
Cavallini, Gian Maria; Volante, Veronica; Campi, Luca; De Maria, Michele; Fornasari, Elisa; Urso, Giancarlo
2017-06-14
We describe the clinicopathological and ultrastructural features of an opaque single-piece hydrophilic acrylic intraocular lens (IOL) explanted from a patient. The main outcome of this report is the documentation of calcium deposits confirmed by surface analysis. The decrease in visual acuity was due to the opacification of the IOL. The opacification involved both the optic plate and the haptics. The analysis at the scansion electron microscope revealed that the opacity was caused by the deposition of calcium and phosphate within the lens optic and haptics. This is the first case about the opacification of an Oculentis L-313. The opacification was characterized by calcium and phosphate deposition probably due to a morphological alteration of the posterior surface of the IOL.
Postoperative inflammatory reactions to intraocular lense sterilized with ethylene-oxide.
Stark, W J; Rosenblum, P; Maumenee, A E; Cowan, C L
1980-05-01
Postoperative inflammatory complications after intraocular lens implantation have increased since we have been using lenses manufactured by American companies and sterilized with ethylene-oxide, as compared with lenses from European companies sterilized by sodium hydroxide. The possible sources of this complication are discussed.
Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics
Kim, Joohee; Kim, Minji; Lee, Mi-Sun; Kim, Kukjoo; Ji, Sangyoon; Kim, Yun-Tae; Park, Jihun; Na, Kyungmin; Bae, Kwi-Hyun; Kyun Kim, Hong; Bien, Franklin; Young Lee, Chang; Park, Jang-Ung
2017-01-01
Wearable contact lenses which can monitor physiological parameters have attracted substantial interests due to the capability of direct detection of biomarkers contained in body fluids. However, previously reported contact lens sensors can only monitor a single analyte at a time. Furthermore, such ocular contact lenses generally obstruct the field of vision of the subject. Here, we developed a multifunctional contact lens sensor that alleviates some of these limitations since it was developed on an actual ocular contact lens. It was also designed to monitor glucose within tears, as well as intraocular pressure using the resistance and capacitance of the electronic device. Furthermore, in-vivo and in-vitro tests using a live rabbit and bovine eyeball demonstrated its reliable operation. Our developed contact lens sensor can measure the glucose level in tear fluid and intraocular pressure simultaneously but yet independently based on different electrical responses. PMID:28447604
Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics.
Kim, Joohee; Kim, Minji; Lee, Mi-Sun; Kim, Kukjoo; Ji, Sangyoon; Kim, Yun-Tae; Park, Jihun; Na, Kyungmin; Bae, Kwi-Hyun; Kyun Kim, Hong; Bien, Franklin; Young Lee, Chang; Park, Jang-Ung
2017-04-27
Wearable contact lenses which can monitor physiological parameters have attracted substantial interests due to the capability of direct detection of biomarkers contained in body fluids. However, previously reported contact lens sensors can only monitor a single analyte at a time. Furthermore, such ocular contact lenses generally obstruct the field of vision of the subject. Here, we developed a multifunctional contact lens sensor that alleviates some of these limitations since it was developed on an actual ocular contact lens. It was also designed to monitor glucose within tears, as well as intraocular pressure using the resistance and capacitance of the electronic device. Furthermore, in-vivo and in-vitro tests using a live rabbit and bovine eyeball demonstrated its reliable operation. Our developed contact lens sensor can measure the glucose level in tear fluid and intraocular pressure simultaneously but yet independently based on different electrical responses.
Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics
NASA Astrophysics Data System (ADS)
Kim, Joohee; Kim, Minji; Lee, Mi-Sun; Kim, Kukjoo; Ji, Sangyoon; Kim, Yun-Tae; Park, Jihun; Na, Kyungmin; Bae, Kwi-Hyun; Kyun Kim, Hong; Bien, Franklin; Young Lee, Chang; Park, Jang-Ung
2017-04-01
Wearable contact lenses which can monitor physiological parameters have attracted substantial interests due to the capability of direct detection of biomarkers contained in body fluids. However, previously reported contact lens sensors can only monitor a single analyte at a time. Furthermore, such ocular contact lenses generally obstruct the field of vision of the subject. Here, we developed a multifunctional contact lens sensor that alleviates some of these limitations since it was developed on an actual ocular contact lens. It was also designed to monitor glucose within tears, as well as intraocular pressure using the resistance and capacitance of the electronic device. Furthermore, in-vivo and in-vitro tests using a live rabbit and bovine eyeball demonstrated its reliable operation. Our developed contact lens sensor can measure the glucose level in tear fluid and intraocular pressure simultaneously but yet independently based on different electrical responses.
Oshika, T.; Nagata, T.; Ishii, Y.
1998-01-01
AIMS—To investigate the adhesion characteristics of several intraocular lenses (IOLs) to the simulated and rabbit lens capsule. METHODS—Adhesive force to bovine collagen sheets was measured in water with polymethylmethacrylate (PMMA), three piece silicone, and acrylic foldable IOLs. In rabbit eyes, phacoemulsification and IOL implantation were performed. Three weeks later, adhesion between the anterior/posterior capsules and IOL optic was tested, and the capsule was examined histologically. RESULTS—The mean adhesive force to the collagen sheet was 1697 (SD 286) mg for acrylic foldable, 583 (49) mg for PMMA, and 0 mg for silicone IOLs (p=0.0003, Kruskal-Wallis test). Scores (0-5) of adhesion between rabbit anterior capsule and IOL optic were 4.50 (0.55) for acrylic foldable, 3.20 (0.84) for PMMA, and 0.40 (0.55) for silicone IOLs (p=0.004). Scores between rabbit posterior capsule and IOL optic displayed a similar tendency; 4.50 (0.84) for acrylic foldable, 3.00 (1.00) for PMMA, and 0.40 (0.55) for silicone IOLs (p=0.021). Histological observation indicated that the edge of IOL optic suppressed the migration of lens epithelial cells towards the centre of the posterior capsule. This inhibitory effect was most pronounced with acrylic foldable IOL and least with silicone IOL. CONCLUSIONS—The acrylic foldable IOL adhered to the lens capsule more than the PMMA IOL, and the silicone IOL showed no adhesiveness. These differences seem to play a role in preventing lens epithelial cells from migrating and forming posterior capsule opacification. Keywords: intraocular lens; lens capsule; posterior capsule opacification; adhesion PMID:9713064
Phakic iris-fixated intraocular lens placement in the anterior chamber: effects on aqueous flow.
Repetto, Rodolfo; Pralits, Jan O; Siggers, Jennifer H; Soleri, Paolo
2015-05-01
Phakic intraocular lenses (pIOLs) are used for correcting vision; in this paper we investigate the fluid dynamical effects of an iris-fixated lens in the anterior chamber. In particular, we focus on changes in the wall shear stress (WSS) on the cornea and iris, which could be responsible for endothelial and pigment cell loss, respectively, and also on the possible increase of the intraocular pressure, which is known to correlate with the incidence of secondary glaucoma. We use a mathematical model to study fluid flow in the anterior chamber in the presence of a pIOL. The governing equations are solved numerically using the open source software OpenFOAM. We use an idealized standard geometry for the anterior chamber and a realistic geometric description of the pIOL. We consider separately the main mechanisms that produce fluid flow in the anterior chamber. The numerical simulations allow us to obtain a detailed description of the velocity and pressure distribution in the anterior chamber, and indicated that implantation of the pIOL significantly modifies the fluid dynamics in the anterior chamber. However, lens implantation has negligible influence on the intraocular pressure and does not produce a significant increase of the shear stress on the cornea, while the shear stress on the iris, although increased, is not enough to cause detachment of cells. We conclude that alterations in the fluid dynamics in the anterior chamber as a result of lens implantation are unlikely to be the cause of medical complications associated with its use.
Bayar, Sezin Akca; Pinarci, Eylem Yaman; Karabay, Gulten; Akman, Ahmet; Oto, Sibel; Yilmaz, Gursel
2014-01-01
To report the ocular findings of patients with Alport syndrome and the results of clear lens extraction in this patient group. Twenty-three eyes of 15 patients with a diagnosis of Alport syndrome were included in this study. Clear corneal phacoemulsification and intraocular foldable lens implantation was performed in eyes with indeterminate refractive errors and/or poor visual acuity and anterior capsule samples were analyzed with electron microscopy. All patients had a history of hereditary nephritis and/or deafness as systemic involvement. Ophthalmologic examination revealed anterior lenticonus with high myopia and/or irregular astigmatism in all patients. The mean best-corrected visual acuity (BCVA) was 0.67 ± 0.17 logMAR (range 1.0-0.4) preoperatively and 0.17 ± 0.08 logMAR (range 0.3-0.0) postoperatively. Postoperative refractive lenticular astigmatism dramatically decreased and no ocular complications arose during the follow-up period. Transmission electron microscopic analysis of the lens capsules supported the diagnosis of Alport syndrome. Clear lens phacoemulsification and foldable intraocular lens implantation is a safe and effective therapeutic choice for the management of uncorrectable refractive errors and low visual acuity due to anterior lenticonus in patients with Alport syndrome.
Effect of humidity on posterior lens opacification during fluid-air exchange.
Harlan, J B; Lee, E T; Jensen, P S; de Juan, E
1999-06-01
To study the relationship of humidity and the rate of lens opacity formation during fluid-air exchange using an animal model. Vitrectomy and fluid-air exchange was carried out using 16 eyes of 8 pigmented rabbits. One eye of each rabbit was exposed to dry air and the fellow eye received humidified air using an intraocular air humidifier. In each case, the percent humidity of the intraocular air was measured using an in-line hygrometer. Elapsed time from initial air entry to lens feathering was recorded for each eye, with the surgeon-observer unaware of the percent humidity of the air infusion. In each rabbit, use of humidified air resulted in a delay in lens feathering (P<.02), with an overall increase in time to feathering of 80% for humidified air vs room air. Use of a humidifier during fluid-air exchange prolongs intraoperative lens clarity in the rabbit model, suggesting that humidified air should prolong lens clarity during phakic fluid-air exchange in patients. Use of humidified air during vitrectomy and fluid-air exchange may retard the intraoperative loss of lens clarity, promoting better visualization of the posterior segment and enhancing surgical performance.
Escobar-Gomez, Marcela; Apple, David J; Vargas, Luis G; Werner, Liliana; Arthur, Stella N; Pandey, Suresh K; Izak, Andrea M; Schmidbauer, Josef M
2003-01-01
To evaluate the properties of the AcrySof(R) SA30AL (Alcon Laboratories, Inc.) single-piece foldable posterior chamber intraocular lens (IOL). Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA. Two nonimplanted clinical-quality AcrySof IOLs were examined by gross, light, and scanning electron microscopy (SEM). In addition, 2 eyes implanted with this IOL obtained post-mortem, the first such eyes accessioned in our laboratory and the first described to date, were examined using the Miyake-Apple posterior photographic technique and by histologic sections. Scanning electron microscopy of the SA30AL IOL showed excellent surface finish. The edge of the optic was square (truncated) and had a matte (velvet or ground-glass) appearance, a feature that may minimize edge glare and other visual phenomena. A well-fabricated square or truncated optic edge was demonstrated. Miyake-Apple analysis revealed that the SA30AL IOL showed appropriate fit and configuration within the capsular bag. Histologic correlation of the IOL's square edge and its relation to the capsular bag and adjacent Soemmering's ring were noted. The AcrySof SA30AL IOL is a well-fabricated lens that situates well in the capsular bag. The truncated optic and its relationship to adjacent structures show a morphological profile that has been shown to be highly efficacious in reducing the rate of posterior capsule opacification.
Stability and safety of MA50 intraocular lens placed in the sulcus.
Kemp, P S; Oetting, T A
2015-11-01
To describe the safety and stability of sulcus placement of the MA50 intraocular lens (IOL). Consecutive patients with MA50 IOLs placed in the sulcus at the University of Iowa Hospitals and Clinics, Iowa City, Iowa, USA, from 1997 to 2012 were identified. Inclusion criteria included patients with over 4 weeks of follow-up data. AEL was compared with incidence of IOL decentration using at two-tailed Student's t-test. Fifty eyes of 49 patients meeting the inclusion criteria were identified. Four weeks post-operatively, the average best-corrected visual acuity was 20/30. IOL decentration occurred in 14% of patients; patients with decentered IOLs had a significantly longer average AEL (25.37 mm) than patients whose IOL remained centered (23.94 mm, P=0.017). Other complications included uveitis-glaucoma-hyphema syndrome (12%), iritis (8%), and glaucoma (6%). There were no cases of pigment dispersion syndrome or need for lens exchange. Twelve eyes (24%) had intra-operative optic capture by the anterior capsule, none of which had post-operative decentration. The MA50 IOL is a reasonable, stable option for placement in the sulcus, with a low-risk profile; however, in eyes with longer AEL and presumably larger anterior segment, surgeons should consider placing an IOL with longer haptic distance than the MA50 to maintain centration. Optic capture of the MA50 IOL by the anterior capsule should be considered for longer eyes, as it is protective against decentration.
Rasp, Max; Bachernegg, Alexander; Seyeddain, Orang; Ruckhofer, Josef; Emesz, Martin; Stoiber, Josef; Grabner, Günther; Dexl, Alois K
2012-11-01
To compare changes in reading performance parameters after implantation of 4 multifocal intraocular lens (IOL) models and a monofocal IOL. Department of Ophthalmology, Paracelsus Medical University, Salzburg, Austria. Prospective randomized controlled clinical trial. Patients with bilateral cataract without additional ocular pathology were scheduled for bilateral implantation of Acri.Smart 48S monofocal, Acrysof Restor SN6AD3 apodized multifocal, AT LISA 366D diffractive multifocal, Tecnis ZMA00 diffractive multifocal, or Rezoom refractive multifocal IOLs. Bilateral corrected and uncorrected reading acuity, reading distance, mean and maximum reading speeds, and smallest log-scaled print size of a Radner reading chart were evaluated under bright lighting conditions (500 lux) using the Salzburg Reading Desk. Pupil size was not measured throughout the trial. The minimum follow-up was 12 months. The diffractive multifocal groups had significantly better uncorrected reading acuity and uncorrected smallest print size than the monofocal and refractive multifocal groups 1, 6, and 12 months postoperatively. The diffractive IOL groups had comparable uncorrected reading distance of approximately 32 cm, which was larger in the monofocal group (38.9 ± 8.4 cm) and refractive multifocal group (37.1 ± 7.3 cm) at the last visit. Patients with diffractive IOLs could read print sizes of approximately 0.74 to 0.87 mm, which was much better than in the monofocal and refractive multifocal groups. The diffractive AT LISA IOL provided the best reading speed values (mean and maximum, corrected and uncorrected). Multifocal IOLs with a diffractive component provided good reading performance that was significantly better than that obtained with a refractive multifocal or monofocal IOL. Drs. Grabner and Dexl were patent owners of the Salzburg Reading Desk technology (now owned by SRD-Vision, LLC). No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Bar-Sela, Shai M; Har-Noy, Nurit Birman; Spierer, Abraham
2014-08-01
To evaluate the risk factors for secondary membrane (SM) formation after congenital cataract surgery with intraocular lens (IOL) implantation. A retrospective non-interventional comparative study. Thirty-nine patients (63 eyes) aged 1-135 months. The study included patients who underwent cataract extraction and primary IOL implantation between 1994 and 2001 at the University Hospital. The postoperative follow-up was 6-24 months. Thirty-three eyes received a poly(methyl methacrylate) (PMMA) IOL without square edges, 29 eyes received a hydrophobic acrylic IOL with truncated square edges (AcrySof), and there was no data for IOL type in one eye. Thirty-nine eyes had primary posterior capsulotomy (PPC) and anterior vitrectomy (AV) and in 24 eyes the posterior capsule was left intact. Cox proportional hazard regression analysis was performed to identify significant risk factors for SM formation, and Wilcoxon test to evaluate the difference in time from surgery to SM formation. SM developed in 24 eyes (38 %)--58 % of eyes with an intact posterior capsule and 26 % of eyes having PPC and AV, 42 % of eyes with a PMMA IOL, and 34 % of eyes with an AcrySof lens. In multivariate Cox regression analysis intraoperative PPC and AV (P = 0.02) and AcrySof lens implantation (P = 0.097) were associated with decreased postoperative incidence of SM formation. Median time until SM development was 2.9 months with PMMA IOLs (range 1-17 months) and 6 months with AcrySof lenses (range 1-21.8 months) (P = 0.037). Posterior capsule management as well as IOL design and material influence the incidence and the timing of SM formation after primary IOL implantation in children.
Moshirfar, Majid; Fenzl, Carlton R; Meyer, Jay J; Neuffer, Marcus C; Espandar, Ladan; Mifflin, Mark D
2011-02-01
To evaluate the safety, efficacy, and visual outcomes of simultaneous and sequential implantation of Intacs (Addition Technology, Inc, Sunnyvale, CA) and Verisyse phakic intraocular lens (AMO, Santa Ana, CA) in selected cases of ectatic corneal disease. John A. Moran Eye Center, University of Utah, UT. Prospective data were collected from 19 eyes of 12 patients (5 eyes, post-laser in situ keratomileusis ectasia and 14 eyes, keratoconus). Intacs segments were implanted followed by insertion of a phakic Verisyse lens at the same session (12 eyes) in the simultaneous group or several months later (7 eyes) in the sequential group. The uncorrected visual acuity, best spectacle-corrected visual acuity (BSCVA), and manifest refraction were recorded at each visit. No intraoperative or postoperative complications were observed. At the last follow-up (19 ± 6 months), in the simultaneous group, mean spherical error was -0.79 ± 1.0 diopter (D) (range, -2.0 to +1.50 D) and cylindrical error +2.06 ± 1.21 D (range, +0.5 to +3.75 D). In the sequential group, at the last follow-up, at 36 ± 21 months, the mean spherical error was -1.64 ± 1.31 D (range, -3.25 to +1.0 D) and cylindrical error +2.07 ± 1.03 D (range, +0.75 to +3.25 D). There were no significant differences in mean uncorrected visual acuity or BSCVA between the 2 groups preoperatively or postoperatively. No eye lost lines of preoperative BSCVA. Combined insertion of Intacs and Verisyse was safe and effective in all cases. The outcomes of the simultaneous implantation of the Intacs and Verisyse lens in 1 surgery were similar to the results achieved with sequential implantation using 2 surgeries.
[Representation and mathematical analysis of human crystalline lens].
Tălu, Stefan; Giovanzana, Stefano; Tălu, Mihai
2011-01-01
The surface of human crystalline lens can be described and analyzed using mathematical models based on parametric representations, used in biomechanical studies and 3D solid modeling of the lens. The mathematical models used in lens biomechanics allow the study and the behavior of crystalline lens on variables and complex dynamic loads. Also, the lens biomechanics has the potential to improve the results in the development of intraocular lenses and cataract surgery. The paper presents the most representative mathematical models currently used for the modeling of human crystalline lens, both optically and biomechanically.
Visual performance after the implantation of a new trifocal intraocular lens
Vryghem, Jérôme C; Heireman, Steven
2013-01-01
Purpose To evaluate the subjective and objective visual results after the implantation of a new trifocal diffractive intraocular lens. Methods A new trifocal diffractive intraocular lens was designed combining two superimposed diffractive profiles: one with +1.75 diopters (D) addition for intermediate vision and the other with +3.50 D addition for near vision. Fifty eyes of 25 patients that were operated on by one surgeon are included in this study. The uncorrected and best distance-corrected monocular and binocular, near, intermediate, and distance visual acuities, contrast sensitivity, and defocus curves were measured 6 months postoperatively. In addition to the standard clinical follow-up, a questionnaire evaluating individual satisfaction and quality of life was submitted to the patients. Results The mean age of patients at the time of surgery was 70 ± 10 years. The mean uncorrected and corrected monocular distance visual acuity (VA) were LogMAR 0.06 ± 0.10 and LogMAR 0.00 ± 0.08, respectively. The outcomes for the binocular uncorrected distance visual acuity were almost the same (LogMAR −0.04 ± 0.09). LogMAR −010 ± 0.15 and 0.02 ± 0.06 were measured for the binocular uncorrected intermediate and near VA, respectively. The distance-corrected visual acuity was maintained in mesopic conditions. The contrast sensitivity was similar to that obtained after implantation of a bifocal intraocular lens and did not decrease in mesopic conditions. The binocular defocus curve confirms good VA even in the intermediate distance range, with a moderate decrease of less than LogMAR 0.2 at −1.5 D, with respect to the best distance VA at 0 D defocus. Patient satisfaction was high. No discrepancy between the objective and subjective outcomes was evidenced. Conclusion The introduction of a third focus in diffractive multifocal intraocular lenses improves the intermediate vision with minimal visual discomfort for the patient. PMID:24124348
Mester, Ulrich; Lohmann, Chris; Pleyer, U; Steinkamp, G; Völcker, E; Kruger, H; Raj, Palaniswamy Sunder
2002-01-01
To compare the efficacy, tolerability and local tolerance of diclofenac sodium 0.1% containing hydroxypropylgamma cyclodextrin preserved with benzalkonium chloride 0.005% (Voltaren Ophtha CD), with that of diclofenac sodium 0.1% preserved with thiomersal 0.004% (Voltaren Ophtha) in the treatment of inflammation after cataract-intraocular lens surgery. Randomised 2:1, double-masked, parallel-group study in six centres in Germany. 299 patients scheduled to undergo phacoemulsification with posterior chamber intraocular lens implantation. Study medications were instilled four times in the 30 minutes before surgery and four times daily from the first postoperative day. The key efficacy variable was the reduction in anterior chamber flare (photons/millisecond) from day 1 to day 6 to 8. Patients underwent comprehensive ocular examinations, including laser flaremetry (KOWA), preoperatively and postoperatively at days 1, 6 to 8 and 24 to 32. 268 patients (Voltaren Ophtha CD 177, Voltaren Ophtha 91) completed the day 6 to 8 visit without any protocol violations. Reduction in the degree of intraocular inflammation with Voltaren Ophtha CD was equivalent to that achieved with Voltaren Ophtha at the day 6 to 8 [95% confidence interval (CI) -3.07 to +0.54] and day 24 to 32 (95% CI -1.44 to +1.40) visits. Although there was no significant (p = 0.464) difference between the two study groups in patients' global assessment of local tolerance at day 24 to 32, ocular discomfort was significantly (p = 0.023) less with Voltaren Ophtha CD compared with Voltaren Ophtha. Voltaren Ophtha CD was as effective and well tolerated but had less ocular discomfort compared with Voltaren Ophtha in the treatment of ocular inflammation after phacoemulsification with intraocular lens implantation. This new formulation of diclofenac sodium 0.1% may be used as an alternative to the existing formulations of ophthalmic diclofenac sodium 0.1%.
Intraocular lenses in age-related macular degeneration.
Grzybowski, Andrzej; Wasinska-Borowiec, Weronika; Alio, Jorge L; Amat-Peral, Pedro; Tabernero, Juan
2017-09-01
The aim of this work is to review the lenses, assessing their advantages and disadvantages. We describe a total of seven types of intraocular lenses (IOLs) recommended for age-related macular degeneration (AMD). We used the PubMed web platform to search for implantable devices in various stages of AMD. We searched for both prospective and retrospective studies and also case reports. Clinical results in AMD patients have been described for a total of seven types of IOLs recommended for AMD: an implantable miniature telescope (IMT), IOL-VIP System, Lipshitz macular implant (LMI), sulcus-implanted Lipshitz macular implant, LMI-SI, Fresnel Prism Intraocular Lens, iolAMD and Scharioth Macula Lens. We conclude that to objectively ascertain the effectiveness and safety of these lenses, further independent clinical studies with longer follow-up data are necessary prior to the general use of these optical devices.
Corneal edema and permanent blue discoloration of a silicone intraocular lens by methylene blue.
Stevens, Scott; Werner, Liliana; Mamalis, Nick
2007-01-01
To report a silicone intraocular lens (IOL) stained blue by inadvertent intraoperative use of methylene blue instead of trypan blue and the results of experimental staining of various lens materials with different concentrations of the same dye. A "blue dye" was used to enhance visualization during capsulorhexis in a patient undergoing phacoemulsification with implantation of a three-piece silicone lens. Postoperatively, the patient presented with corneal edema and a discolored IOL. Various IOL materials were experimentally stained using methylene blue. Sixteen lenses (4 silicone, 4 hydrophobic acrylic, 4 hydrophilic acrylic, and 4 polymethylmethacrylate) were immersed in 0.5 mL of methylene blue at concentrations of 1%, 0.1%, 0.01%, and 0.001%. These lenses were grossly and microscopically evaluated for discoloration 6 and 24 hours after immersion. The corneal edema resolved within 1 month after the initial surgical procedure. After explantation, gross and microscopic analyses of the explanted silicone lens revealed that its surface and internal substance had been permanently stained blue. In the experimental study, all of the lenses except the polymethylmethacrylate lenses were permanently stained by methylene blue. The hydrophilic acrylic lenses showed the most intense blue staining in all dye concentrations. This is the first clinicopathological report of IOL discoloration due to intraocular use of methylene blue. This and other tissue dyes may be commonly found among surgical supplies in the operating room and due diligence is necessary to avoid mistaking these dyes for those commonly used during ocular surgery.
[To exercise caution in developing intraocular lens exchange].
Song, X D; Wang, X Z; Qian, J
2018-05-11
Nowadays cataract extraction combined intraocular lens (IOL) implantation has become the conventional treatment for cataract. Numbers of IOL exchange after cataract extraction combined IOL implantation have been increasing in recent years. As a non-routine surgery, IOL exchange is normally combined with other surgeries and accompanied by some complications to various extents. Is IOL exchange necessary for all abnomal IOLs? Can IOL exchange be avoided? How to avoid IOL exchange? The purpose of this article is to stress the importance of indication of IOL exchange and how to avoid IOL exchange. (Chin J Ophthalmol, 2018, 54: 324-327) .
Curvularia lunata endophthalmitis.
Berbel, Rodrigo Fabri; Casella, Antonio Marcelo Barbante; de Freitas, Denise; Höfling-Lima, Ana Luisa
2011-10-01
The aim of this study was to report a case of a 52-year-old man with a rare fungal endophthalmitis after penetrating ocular trauma with a fish hook. The patient was submitted to wound repair and hook extraction. Three weeks after the trauma, a cataract extraction with phacoemulsification and in-the-bag intraocular lens implantation was performed. After the development of endophthalmitis, vitrectomy and lens explantation with positive culture for Curvularia lunata were carried out. The infection was controlled with the administration of systemic itraconazole and intraocular voriconazole. The use of intravitreal voriconazole injection is a viable option in cases of Curvularia fungal endophthalmitis.
Anisimova, Natalia; Malyugin, Boris; Arbisser, Lisa B.; Sobolev, Nikolay
2017-01-01
Summary We describe a case of femtosecond laser–assisted cataract surgery (FLACS) in an eye with multiple comorbidities, including retinal detachment surgery, high myopia, posterior chamber phakic intraocular lens (PC pIOL) and residual, emulsified, silicone oil located in the anterior chamber. FLACS was affected by the optical blockage, but the incomplete capsular tear was recoverable. The case suggests that silicone oil bubbles concentrated at the dome of the posterior corneal surface, along with the PC pIOL optic edges and scars after corneal astigmatic relaxing incisions can lead to incomplete anterior capsulotomy. PMID:28924422
Management of bipseudophakia with implantation of an iris claw lens.
Izak, Milan G J; Werner, Liliana; Izak, Andrea M; Apple, David J
2003-07-01
We discuss a case of bipseudophakia with secondary dislocation of a posterior chamber intraocular lens (IOL) into the anterior chamber that was managed by explantation of the anterior and posterior chamber IOLs and implantation of an iris claw IOL.
Brazitikos, Periklis D; Balidis, Miltiadis O; Tranos, Paris; Androudi, Sofia; Papadopoulos, Nick T; Tsinopoulos, Ioannis T; Karabatakis, Vasilios; Stangos, Nikolaos T
2002-09-01
To evaluate the safety of implanting a 3-piece, 6.0 mm optic, foldable acrylic intraocular lens (IOL) in cases of posterior capsule rupture during phacoemulsification. Department of Ophthalmology, Ahepa Hospital, Aristotle University Medical School, and Interbalkan Medical Center, Thessaloniki, Greece. This prospective noncomparative case series included 28 eyes (28 patients) having phacoemulsification complicated by extensive posterior capsule rupture with or without vitreous loss. In all eyes, a 3-piece, 6.0 mm optic, foldable acrylic IOL (AcrySof MA60BM, Alcon) was implanted in the sulcus. Postoperative examination included best corrected visual acuity (BCVA), anterior segment biomicroscopy, IOL centralization and position, intraocular pressure (IOP), and fundus biomicroscopy. The follow-up was 6 months. The most common postoperative complications were transient corneal edema in 12 eyes and increased IOP in 11 eyes. Slight asymptomatic decentralization from the center of the pupil (1.0 to 2.0 mm) and pseudophacodonesis were observed in 5 eyes each. Friction of the IOL with the iris occurred in 1 eye. Clinically significant cystoid macular edema occurred in 3 eyes. The final BCVA was between 20/15 and 20/25 in 18 patients, 20/30 in 2, between 20/40 and 20/50 in 4, and between 20/60 and 20/200 in 4. AcrySof IOL implantation in the sulcus during phacoemulsification complicated by posterior capsule rupture preserved the advantages of small-incision surgery. The postoperative behavior and centralization of the IOLs resembled those of poly(methyl methacrylate) lenses.
Kavitha, V; Balasubramanian, Preethi; Heralgi, Mallikarjun M.
2016-01-01
Aim: This study aims to compare visual outcomes and complications of iris-fixated (claw) intraocular lens (IFIOL) implantation with those of posterior chamber intraocular lens (PCIOL) implantation in children with traumatic cataract. Settings and design: Retrospective observational clinical audit. Materials and methods: A total of 50 pediatric traumatic cataract cases that underwent lens removal and IOL implantation (IFIOL or PCIOL) with or without corneal or corneoscleral tear repair between January 2009 and December 2013 were analyzed. After meeting the eligibility criteria, their pre- and postoperative visual outcomes and complication rates were recorded. Data were analyzed descriptively. Results: Out of 50 children, IFIOL and PCIOL implantations were performed in one eye of each of 25 children. Their mean age was 11 ± 4 years (range 4–18 years). Primary (cataract removal with lens implantation) and secondary (corneal tear repair followed by cataract removal with lens implantation) procedures were performed in 19 (76%) and six (24%) children in the IFIOL group and in 21 (84%) and four (16%) children in the PCIOL group, respectively. There was an improvement in best corrected visual acuity postimplantation in both the IFIOL and the PCIOL group, and no significant difference in the logarithm of the minimum angle of resolution of best corrected visual acuity was observed between the two groups over 36 months. Only three eyes in the IFIOL group developed complications: one eye developed secondary glaucoma, one disenclavation of IOL haptic, and one cystoid macular edema. Conclusion: Both IFIOL and PCIOL implantations have good visual outcomes and minimal postoperative complications; therefore, IFIOL can be used as an alternative to PCIOL in children with traumatic cataract with inadequate capsular support. PMID:29018714
Wang, Yan; Wu, Mingxing; Zhu, Liyuan; Liu, Yizhi
2012-04-01
To evaluate long-term corneal endothelial cell changes of intraocular lens (IOL) reposition and exchange in children. State key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, 510060, China In this retrospective study, all IOL reposition and exchange procedures performed in patients under 14 years old between January 1999 and April 2009 were included. Follow-up outcomes included corneal endothelial cell density, hexagonality, coefficient of variance, average cell size. IOL reposition procedures in 12 eyes (12 cases) (reposition group, RPG), and IOL exchanges in eight eyes (eight cases) (exchange group, EXG) were performed because of IOL pupillary capture or IOL dislocation. Median of follow-up was 44.5 months in RPG and 66.2 months in EXG. The density of corneal endothelial cells in RPG (2,053 ± 493/mm(2)) and EXG (2,100 ± 758/mm(2)) was significantly decreased in comparison to the control eyes (3,116 ± 335/mm(2)). Hexagonality of corneal endothelial cells and coefficient of variance showed no difference among the control group, RPG and EXG (P > 0.05). The density of corneal endothelial cells was conspicuously decreased after IOL reposition or exchange procedures in childhood cases. Longer follow-up must be conducted in these cases.
Hu, Shufang; Wang, Mingling; Xiao, Tianlin; Zhao, Zhenquan
2016-03-01
To study the efficiency and safety of iris reconstruction combined with iris-claw intraocular lens (IOL) implantation in the patients with iris-lens injuries. Retrospective, noncomparable consecutive case series study. Eleven patients (11 eyes) following iris-lens injuries underwent iris reconstructions combined with iris-claw IOL implantations. Clinical data, such as cause and time of injury, visual acuity (VA), iris and lens injuries, surgical intervention, follow-up period, corneal endothelial cell count, and optical coherence tomography, were collected. Uncorrected VA (UCVA) in all injured eyes before combined surgery was equal to or <20/1000. Within a 1.1-4.2-year follow-up period, a significant increase, equal to or better than 20/66, in UCVA was observed in six (55%) cases, and in best-corrected VA (BCVA) was observed in nine (82%) cases. Postoperative BCVA was 20/40 or better in seven cases (64%). After combined surgery, the iris returned to its natural round shape or smaller pupil, and the iris-claw IOLs in the 11 eyes were well-positioned on the anterior surface of reconstructed iris. No complications occurred in those patients. Iris reconstruction combined with iris-claw IOL implantation is a safe and efficient procedure for an eye with iris-lens injury in the absence of capsular support.
Owens, S L; Lam, S; Tessler, H H; Deutsch, T A
1993-04-01
Late endophthalmitis, due to Propionibacterium acnes, developed in three patients following uncomplicated extracapsular cataract extraction and posterior chamber intraocular lens (PC-IOL) insertion. Cultures from the capsular bag yielded P. acnes in all three. With topical anesthesia and through an anterior chamber paracentesis, culture specimens were taken from and clindamycin irrigated into the capsular bag. Filtered 100% oxygen was introduced into the anterior chamber in two; the third also received an injection of gentamicin and dexamethasone into the capsular bag. After treatment, two patients received oral antibiotics; one received hyperbaric oxygen therapy. Visual acuity was improved and inflammation reduced in all three. However, after treatment, ocular toxic effects due to clindamycin were suspected in one. This approach offers several clear advantages, including topical anesthesia, outpatient management, elimination of the need for vitrectomy, and retention of the intraocular lens (IOL).
Itagaki, Hideo; Kunikata, Toshio; Hiratsuka, Kentaro; Saito, Junichiro; Oshika, Tetsuro
2013-12-01
A 61-year-old man with high myopia who had received a systemic α1A-adrenoceptor antagonist had phacoemulsification and in-the-bag intraocular lens implantation in the right eye. One day postoperatively, marked pigment dispersion in the anterior chamber, posterior bowing of the iris, and iridodonesis were noted associated with a subsequent elevation in intraocular pressure (IOP). Pharmacological pupil dilation was effective in reducing pigment dispersion and IOP, and laser peripheral iridotomy was performed to alleviate posterior bowing of the iris. We hypothesize that dynamic changes in the aqueous humor flow by cataract surgery and latent flaccidity of the iris due to the systemic α1A-adrenoceptor antagonist caused reverse pupillary block. High myopia may be another risk factor for this complication. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Farah, Edgard; Koutsandrea, Chryssanthi; Papaefthimiou, Ioannis; Papaconstantinou, Dimitris; Georgalas, Ilias
2013-01-01
Laser peripheral iridotomy is the procedure of choice for the treatment of angle-closure glaucoma caused by relative or absolute pupillary block. Nd: YAG laser iridotomy has been reported to have several complications such as Iris bleeding, hyphema, transient IOP elevation, intraocular inflammation, choroidal, retinal detachment and vitreous hemorrhage. We report a case of a 74 year old lady on anticoagulant treatment who developed pupillary block and angle closure glaucoma after cataract surgery and anterior chamber intraocular lens (ACIOL) insertion complicated with intraoperative bleeding. The patient was treated with Nd: YAG laser iridotomy , however, the ACIOL was inadvertently fractured after a single shot of laser and it had to be replaced. Although the incidence is rare. Ophthalmologists and Opticians should be aware that an ACIOL may be fractured even after a single Nd:YAG laser shot and avoid to perform it close to the ACIOL. Pretreatment counseling should include this rare complication.
Tan, Marcus C L; Nah, Gerard K M
2012-02-01
Phakic intraocular lens (PIOL) implantation is a surgical option for correction of refractive errors. PIOLs can be use to correct myopia, hyperopia, and astigmatism. It is a surgical option available to patients in addition to methods such as laser cornea refractive surgery, e.g., laser assisted in-situ keratomileusis (LASIK) and photo-refractive keratectomy (PRK). Visian implantable collamer lens (ICL) are posterior chamber lenses which are surgically positioned in a phakic eye in the sulcus between the iris diaphragm and the natural crystalline lens. This case report describes the stability of Visian toric ICL in a candidate with bilateral implants under high +Gz force exposure in a human centrifuge trainer. The subject was sequentially exposed to three incremental +Gz profiles of +5 Gz, +7 Gz, and +9 Gz. Pre- and post-+Gz exposure, ophthalmic examination revealed no ICL displacement, implant touch or induced cataract, or change in refractive error. The rotational stability of the toric implants was also demonstrated by identical subjective refractions in both eyes taken pre- and post-+Gz, exposure. A search of the literature did not reveal any published articles on intraocular stability of ICL in the +Gz environment. This case report suggests that ICL may be considered an alternative to laser refractive surgery for patients subjected to a high +G, environment such as military aviators.
Doroodgar, Farideh; Jabbarvand, Mahmoud; Niazi, Feizollah; Niazi, Sana; Sanginabadi, Azad
2017-01-01
Abstract Purpose: To evaluate probable complications of ArtificialIris implantation with iris fixated intraocular lens. Method: Development of photophobia, glare, and psychological strain during face-to-face communication in a 23-year-old man with a widespread traumatic iris defect terminate to make a decision for performing implantation of an ArtificialIris (Humanoptics, Erlangen, Germany) under the remnant iris without removing the patient's existing Artisan lens. Results: Without any intraoperative or postoperative complications, the patient's visual acuity increased by 1 line, the endothelial cell loss was comparable with the cell loss associated with standard cataract surgery, and the anterior-chamber depth and anterior-chamber anatomy did not change. At the final follow-up examination, the mean intraocular pressure did not differ from baseline, and we achieved high level of patient satisfaction and subjective vision improvement. We discuss the particular importance of considering the patient's expectations, the appropriate measurements, ways to perfect color evaluation, and the types of ArtificialIris products. Conclusion: The implantation of the ArtificialIris in patients with aphakic iris-supported lenses (ie, pre-existing Artisan lenses) is a feasible approach and a useful option for patients with thin irises and iris hypoplasia who are at risk of subluxation or the dislocation of the posterior-chamber intraocular lens (PCIOL), and also those with sclerally fixed PCIOLs. PMID:29137026
Ladi, Jeevan S; Shah, Nitant A
2016-01-01
We report the first case of toric multifocal intraocular lens (IOL) implantation in both the eyes of a young patient of Alport syndrome with anterior and posterior lenticonus with a successful outcome. An 18-year-old female patient presented with progressively blurred vision in both eyes since 4–5 years not improving with glasses. Refraction showed high myopia with astigmatism; however, the vision did not improve beyond 6/60 with glasses correction. Clinical examination on slit lamp showed anterior and posterior lenticonus bilaterally with a classical oil droplet appearance. We performed clear lens extraction by phacoemulsification with toric multifocal IOL implantation in both eyes. Postoperatively, the patient achieved an excellent refractive outcome with the unaided vision of 6/9, N6 in both eyes. PMID:27958211
Characteristics of the retinal images of the eye optical systems with implanted intraocular lenses
NASA Astrophysics Data System (ADS)
Siedlecki, Damian; Zając, Marek; Nowak, Jerzy
2007-04-01
Cataract, or opacity of crystalline lens in the human eye is one of the most frequent reasons of blindness nowadays. Removing the pathologically altered crystalline lens and replacing it with artificial implantable intraocular lens (IOL) is practically the only therapy in this illness. There exist a wide variety of artificial IOL types on the medical market, differing in their material and design (shape). In this paper six exemplary models of IOL's made of PMMA, acrylic and silicone are considered. The retinal image quality is analyzed numerically on the basis of Liou-Brennan eye model with these IOL's inserted. Chromatic aberration as well as polychromatic Point Spread Function and Modulation Transfer Function are calculated as most adequate image quality measures. The calculations made with Zemax TM software show the importance of chromatic aberration correction.
Sectioning a luxated intraocular lens inside the vitreous cavity.
Vilaplana, Daniel; Pazos, Marta
2013-07-01
We describe a new technique for sectioning an intraocular lens (IOL) inside the vitreous cavity. The IOL had a broken haptic and was accidentally luxated after a complicated cataract surgery with posterior capsule rupture. The primary indication to cut the IOL in half inside the vitreous cavity is to preserve the anterior capsule integrity, especially in a small-sized capsulotomy, allowing subsequent implantation of a new IOL in the sulcus with the optical zone captured in the capsulorhexis. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Alio, Jorge L; Plaza-Puche, Ana B; Javaloy, Jaime; Ayala, María José; Moreno, Luis J; Piñero, David P
2012-03-01
To compare the visual acuity outcomes and ocular optical performance of eyes implanted with a multifocal refractive intraocular lens (IOL) with an inferior segmental near add or a diffractive multifocal IOL. Prospective, comparative, nonrandomized, consecutive case series. Eighty-three consecutive eyes of 45 patients (age range, 36-82 years) with cataract were divided into 2 groups: group A, 45 eyes implanted with Lentis Mplus LS-312 (Oculentis GmbH, Berlin, Germany); group B, 38 eyes implanted with diffractive IOL Acri.Lisa 366D (Zeiss, Oberkochen, Germany). All patients underwent phacoemulsification followed by IOL implantation in the capsular bag. Distance corrected, intermediate, and near with the distance correction visual acuity outcomes and contrast sensitivity, intraocular aberrations, and defocus curve were evaluated postoperatively during a 3-month follow-up. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), corrected distance near and intermediate visual acuity (CDNVA), contrast sensitivity, intraocular aberrations, and defocus curve. A significant improvement in UDVA, CDVA, and UNVA was observed in both groups after surgery (P ≤ 0.04). Significantly better values of UNVA (P<0.01) and CDNVA (P<0.04) were found in group B. In the defocus curve, significantly better visual acuities were present in eyes in group A for intermediate vision levels of defocus (P ≤ 0.04). Significantly higher amounts of postoperative intraocular primary coma and spherical aberrations were found in group A (P<0.01). In addition, significantly better values were observed in photopic contrast sensitivity for high spatial frequencies in group A (P ≤ 0.04). The Lentis Mplus LS-312 and Acri.Lisa 366D IOLs are able to successfully restore visual function after cataract surgery. The Lentis Mplus LS-312 provided better intermediate vision and contrast sensitivity outcomes than the Acri.Lisa 366D. However, the Acri.Lisa design provided better distance and near visual outcomes and intraocular optical performance parameters. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
In-the-bag decentration of an intraocular lens in a patient with a tendency to hypertrophic scarring
Joshi, Rajesh Subhash
2016-01-01
Summary We report a case of rapid anterior lens capsular contraction leading to decentration of a hydrophilic acrylic lens with stiff haptics (Rayner design). To our knowledge, this is the first report to investigate early capsular contraction with folding of the haptic over the optic in a patient with a tendency toward hypertrophic scar formation. PMID:27330480
Functionalised Polysiloxanes as Injectable, In Situ Curable Accommodating Intraocular Lenses
Hao, Xiaojuan; Jeffery, Justine L.; Wilkie, John S.; Meijs, Gordon; Clayton, Anthony; Watling, Jason; Ho, Arthur; Fernandez, Viviana; Acosta, Carolina; Yamamoto, Hideo; Aly, Mohamed G. M.; Parel, Jean-Marie; Hughes, Timothy C.
2010-01-01
The aged eye’s ability to change focus (accommodation) may be restored by replacing the hardened natural lens with a soft gel. Functionalised polysiloxane macromonomers, designed for application as an injectable, in situ curable accommodating intraocular lens (A-IOL), were prepared via a two-step synthesis. Prepolymers were synthesised via ring opening polymerisation (ROP) of octamethylcyclotetrasiloxane (D4) and 2,4,6,8-tetramethylcyclotetrasiloxane (D4H) in toluene using trifluoromethanesulfonic acid (TfOH) as catalyst. Hexaethyldisiloxane (HEDS) was used as the end group to control the molecular weight of the prepolymers, which were then converted to macromonomers by hydrosilylation of the SiH groups with allyl methacrylate (AM) to introduce polymerisable groups. The resulting macromonomers had an injectable consistency and thus, were able to be injected into and refill the empty lens capsular bag. The macromonomers also contained a low ratio of polymerisable groups so that they may be cured on demand, in situ, under irradiation of blue light, in the presence of a photo-initiator, to form a soft polysiloxane gel (an intraocular lens) in the eye. The pre-cure viscosity and post-cure modulus of the polysiloxanes, which are crucial factors for an injectable, in situ curable A-IOL application, were controlled by adjusting the end group and D4H concentrations, respectively, in the ROP. The macromonomers were fully cured within 5 minutes under light irradiation, as shown by the rapid change in modulus monitored by photorheology. Ex vivo primate lens stretching experiments on an Ex Vivo Accommodation Simulator (EVAS) showed that the polysiloxane gel refilled lenses achieved over 60% of the accommodation amplitude of the natural lens. An in vivo biocompatibility study in rabbits using the lens refilling (Phaco-Ersatz) procedure demonstrated that the soft gels were biocompatible with the ocular tissue. The polysiloxane macromonomers meet the targeted optical and mechanical properties of a young natural crystalline lens and show promise as candidate materials for use as injectable, in situ curable A-IOLs for lens refilling procedures. PMID:20692702
Stability and safety of MA50 intraocular lens placed in the sulcus
Kemp, P S; Oetting, T A
2015-01-01
Purpose To describe the safety and stability of sulcus placement of the MA50 intraocular lens (IOL). Patients and methods Consecutive patients with MA50 IOLs placed in the sulcus at the University of Iowa Hospitals and Clinics, Iowa City, Iowa, USA, from 1997 to 2012 were identified. Inclusion criteria included patients with over 4 weeks of follow-up data. AEL was compared with incidence of IOL decentration using at two-tailed Student's t-test. Results Fifty eyes of 49 patients meeting the inclusion criteria were identified. Four weeks post-operatively, the average best-corrected visual acuity was 20/30. IOL decentration occurred in 14% of patients; patients with decentered IOLs had a significantly longer average AEL (25.37 mm) than patients whose IOL remained centered (23.94 mm, P=0.017). Other complications included uveitis-glaucoma-hyphema syndrome (12%), iritis (8%), and glaucoma (6%). There were no cases of pigment dispersion syndrome or need for lens exchange. Twelve eyes (24%) had intra-operative optic capture by the anterior capsule, none of which had post-operative decentration. Conclusion The MA50 IOL is a reasonable, stable option for placement in the sulcus, with a low-risk profile; however, in eyes with longer AEL and presumably larger anterior segment, surgeons should consider placing an IOL with longer haptic distance than the MA50 to maintain centration. Optic capture of the MA50 IOL by the anterior capsule should be considered for longer eyes, as it is protective against decentration. PMID:26139047
Predicting crystalline lens fall caused by accommodation from changes in wavefront error
He, Lin; Applegate, Raymond A.
2011-01-01
PURPOSE To illustrate and develop a method for estimating crystalline lens decentration as a function of accommodative response using changes in wavefront error and show the method and limitations using previously published data (2004) from 2 iridectomized monkey eyes so that clinicians understand how spherical aberration can induce coma, in particular in intraocular lens surgery. SETTINGS College of Optometry, University of Houston, Houston, USA. DESIGN Evaluation of diagnostic test or technology. METHODS Lens decentration was estimated by displacing downward the wavefront error of the lens with respect to the limiting aperture (7.0 mm) and ocular first surface wavefront error for each accommodative response (0.00 to 11.00 diopters) until measured values of vertical coma matched previously published experimental data (2007). Lens decentration was also calculated using an approximation formula that only included spherical aberration and vertical coma. RESULTS The change in calculated vertical coma was consistent with downward lens decentration. Calculated downward lens decentration peaked at approximately 0.48 mm of vertical decentration in the right eye and approximately 0.31 mm of decentration in the left eye using all Zernike modes through the 7th radial order. Calculated lens decentration using only coma and spherical aberration formulas was peaked at approximately 0.45 mm in the right eye and approximately 0.23 mm in the left eye. CONCLUSIONS Lens fall as a function of accommodation was quantified noninvasively using changes in vertical coma driven principally by the accommodation-induced changes in spherical aberration. The newly developed method was valid for a large pupil only. PMID:21700108
Chung, Jin Kwon; Kim, Jin Kook; Lee, Jae Bum; Lee, Sung Jin
2013-10-01
To assess the efficacy and safety of iris-fixated phakic intraocular lens (pIOL) implantation to correct myopia in eyes with previous retinal detachment (RD) surgery. Department of Ophthalmology, Soonchunhyang University College of Medicine, Seoul, South Korea. Retrospective case series. Patients having pIOL implantation in both eyes were enrolled. Eyes that had scleral buckling or encircling (RD group) and healthy fellow eyes (non-RD group) were evaluated over a 6-year follow-up. The corrected distance visual acuity (CDVA), endothelial cell density (ECD), intraoperative complications, and long-term complications were safety outcomes. Uncorrected distance visual acuity (UDVA), predictability, and stability of refraction were efficacy outcomes. The study comprised 34 eyes (17 patients). The mean postoperative CDVA and ECD were not significantly different between groups, and no patient lost CDVA. The rate of transient intraocular pressure spike was significantly higher in the RD group (P=.043). After 3 years and 6 years, the mean postoperative UDVA was 0.06 logMAR ± 0.09 (SD) and 0.08 ± 0.10 logMAR, respectively, in the RD group and 0.04 ± 0.08 logMAR and 0.04 ± 0.09 logMAR, respectively, in the non-RD group (P=.518 and P=.478, respectively). The rate of eyes within ±0.50 diopter of the desired refraction and the postoperative refraction was not significantly different between groups. No eye had vitreoretinal changes requiring secondary surgical intervention. Iris-fixated pIOL implantation corrected the myopic refractive error in patients who had scleral buckling or encircling surgery for RD with a high degree of efficacy, safety, and long-term stability. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Treatment of dystrophic calcification on a silicone intraocular lens with pars plana vitrectomy
Mehta, Nitish; Goldberg, Roger A; Shah, Chirag P
2014-01-01
Purpose Dense, vision-obscuring calcification on the posterior aspect of silicone intraocular lenses (IOLs) is often not amenable to neodymium:yttrium-aluminum-garnet capsulotomy, and, in prior reports, has required IOL exchange. We report the successful removal of dense calcium deposition on the posterior surface of a three-piece silicone lens using pars plana vitrectomy (PPV). Materials and methods A 23-gauge PPV was performed using the Stellaris® vitrectomy system. A light pipe was used to retroilluminate the IOL, and a dense fibrous tissue setting with a low cut-rate and high aspiration rate was able to clear the visual axis of the dystrophic calcification without damaging the IOL optic. Results Visual acuity improved from 20/100 to 20/25. Conclusion Small-gauge PPV may be utilized to remove dense dystrophic calcium deposits on the lens surface in lieu of IOL exchange. PMID:25045246
Hu, Shufang; Wang, Mingling; Xiao, Tianlin; Zhao, Zhenquan
2016-01-01
Aim: To study the efficiency and safety of iris reconstruction combined with iris-claw intraocular lens (IOL) implantation in the patients with iris-lens injuries. Settings and Design: Retrospective, noncomparable consecutive case series study. Materials and Methods: Eleven patients (11 eyes) following iris-lens injuries underwent iris reconstructions combined with iris-claw IOL implantations. Clinical data, such as cause and time of injury, visual acuity (VA), iris and lens injuries, surgical intervention, follow-up period, corneal endothelial cell count, and optical coherence tomography, were collected. Results: Uncorrected VA (UCVA) in all injured eyes before combined surgery was equal to or <20/1000. Within a 1.1–4.2-year follow-up period, a significant increase, equal to or better than 20/66, in UCVA was observed in six (55%) cases, and in best-corrected VA (BCVA) was observed in nine (82%) cases. Postoperative BCVA was 20/40 or better in seven cases (64%). After combined surgery, the iris returned to its natural round shape or smaller pupil, and the iris-claw IOLs in the 11 eyes were well-positioned on the anterior surface of reconstructed iris. No complications occurred in those patients. Conclusions: Iris reconstruction combined with iris-claw IOL implantation is a safe and efficient procedure for an eye with iris-lens injury in the absence of capsular support. PMID:27146932
Posterior capsule opacification.
Wormstone, I Michael; Wang, Lixin; Liu, Christopher S C
2009-02-01
Posterior Capsule Opacification (PCO) is the most common complication of cataract surgery. At present the only means of treating cataract is by surgical intervention, and this initially restores high visual quality. Unfortunately, PCO develops in a significant proportion of patients to such an extent that a secondary loss of vision occurs. A modern cataract operation generates a capsular bag, which comprises a proportion of the anterior and the entire posterior capsule. The bag remains in situ, partitions the aqueous and vitreous humours, and in the majority of cases, houses an intraocular lens. The production of a capsular bag following surgery permits a free passage of light along the visual axis through the transparent intraocular lens and thin acellular posterior capsule. However, on the remaining anterior capsule, lens epithelial cells stubbornly reside despite enduring the rigours of surgical trauma. This resilient group of cells then begin to re-colonise the denuded regions of the anterior capsule, encroach onto the intraocular lens surface, occupy regions of the outer anterior capsule and most importantly of all begin to colonise the previously cell-free posterior capsule. Cells continue to divide, begin to cover the posterior capsule and can ultimately encroach on the visual axis resulting in changes to the matrix and cell organization that can give rise to light scatter. This review will describe the biological mechanisms driving PCO progression and discuss the influence of IOL design, surgical techniques and putative drug therapies in regulating the rate and severity of PCO.
Robert, Pierre-Yves; Chainier, Delphine; Garnier, Fabien; Ploy, Marie-Cécile; Parneix, Pierre; Adenis, Jean-Paul; Martin, Christian
2008-01-01
Five consecutive cases of endophthalmitis that developed after cataract extraction by a single surgeon using the same operating room during one morning session are described. Following preoperative topical administration of ciprofloxacin, surgery consisted of phacoemulsification with peristaltic pump and fluid venting, polymethylmethacrylate intraocular lens implantation, and corneal suture. No complications occurred during surgery. All five patients developed endophthalmitis caused by infection with Alcaligenes xylosoxidans in less than 24 hours. Pulsed-field gel electrophoresis was used to prove similarity between strains. Bacterial inquiry on contamination of the operating room environment revealed massive colonization of phacoemulsifier irrigation channels by Pseudomonas fluorescens bacteria from an unestablished source. Four of the five patients ultimately recovered visual acuity better than 20/60.
Cywinski, Adam; Piwonska-Lobermajer, Anna; Penter, Sandra
2016-08-01
A retrospective analysis of visual function and postoperative complaints in patients after posterior vitrectomy and multifocal Mplus or MplusX intraocular lens implantation. 14 patients (14 eyes) were enrolled in the study. All patients underwent posterior vitrectomy due to underlying retinal pathologies. A combined procedure of phacovitrectomy was performed in some patients, whereas others underwent a separate cataract extraction as a second stage of treatment. The Mplus or MplusX intraocular lenses were implanted in all cases and the postoperative visual function and patient complaints were analysed. Multifocal lens explantation was not necessary in any case. Good uncorrected distance and near visual acuity was achieved in most cases. When implanted prior to vitrectomy, the intraocular lenses did not limit the view into the posterior segment, so precise manipulations within the macula and peripheral retina were feasible. The right choice between Mplus and MplusX minimises the rate of postoperative complaints. Conslusions: The multifocal Mplus and MplusX intraocular lenses offer a good alternative for patients who need posterior vitrectomy and still want to achieve good uncorrected distance and near visual acuity.
Wall, Palak B.; Lee, Jason A.; Lynn, Michael; Lambert, Scott R.; Traboulsi, Elias I.
2015-01-01
Purpose To evaluate the impact of surgical factors such as incision type, number of sutures, and technique of closure on postoperative astigmatism in infants undergoing cataract extraction with or without intraocular lens implantation. Methods The IATS is a multicenter (n=12) clinical trial in which 114 infants with unilateral congenital cataracts were randomized to undergo cataract extraction with intraocular lens (IOL) placement or contact lens aphakic correction. Surgical videos were reviewed with regard to incision type and location, whether the incision was extended, the number of sutures placed, and technique of closure. Corneal astigmatism was measured using a handheld keratometer prior to surgery and at 1 year of age. Results Corneal astigmatism decreased from a mean of 1.92 D at baseline to 1.62 D at age 1 year in the CL group, but remained almost unchanged from 2.00 D to 2.09 D in the IOL group (p=0.023). There was no statistical difference between the amount of corneal astigmatism irrespective of incision type (p=0.214) and no increase in astigmatism with extension of the incision to facilitate IOL placement (p=0.849) at 1 year. The number of sutures and technique of closure did not influence the amount of astigmatism at 1 year. Conclusions At the age of one year following cataract extraction in infants, contact lens correction and the lack of IOL placement are associated with a significant decrease in postoperative corneal astigmatism compared to intraocular lens placement. No other surgical factors considered in this study had a statistically significant impact on corneal astigmatism. PMID:25266831
Hirnschall, Nino; Norrby, Sverker; Weber, Maria; Maedel, Sophie; Amir-Asgari, Sahand; Findl, Oliver
2015-01-01
To include intraoperative measurements of the anterior lens capsule of the aphakic eye into the intraocular lens power calculation (IPC) process and to compare the refractive outcome with conventional IPC formulae. In this prospective study, a prototype operating microscope with an integrated continuous optical coherence tomography (OCT) device (Visante attached to OPMI VISU 200, Carl Zeiss Meditec AG, Germany) was used to measure the anterior lens capsule position after implanting a capsular tension ring (CTR). Optical biometry (intraocular lens (IOL) Master 500) and ACMaster measurements (Carl Zeiss Meditec AG, Germany) were performed before surgery. Autorefraction and subjective refraction were performed 3 months after surgery. Conventional IPC formulae were compared with a new intraoperatively measured anterior chamber depth (ACD) (ACDIntraOP) partial least squares regression (PLSR) model for prediction of the postoperative refractive outcome. In total, 70 eyes of 70 patients were included. Mean axial eye length (AL) was 23.3 mm (range: 20.6-29.5 mm). Predictive power of the intraoperative measurements was found to be slightly better compared to conventional IOL power calculations. Refractive error dependency on AL for Holladay I, HofferQ, SRK/T, Haigis and ACDintraOP PLSR was r(2)=-0.42 (p<0.0001), r(2)=-0.5 (p<0.0001), r(2)=-0.34 (p=0.010), r(2)=-0.28 (p=0.049) and r(2)<0.001 (p=0.866), respectively, ACDIntraOP measurements help to better predict the refractive outcome and could be useful, if implemented in fourth-generation IPC formulae. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Azuara-Blanco, Augusto; Burr, Jennifer M; Cochran, Claire; Ramsay, Craig; Vale, Luke; Foster, Paul; Friedman, David; Quayyum, Zahidul; Lai, Jimmy; Nolan, Winnie; Aung, Tin; Chew, Paul; McPherson, Gladys; McDonald, Alison; Norrie, John
2011-05-23
Glaucoma is the leading cause of irreversible blindness. Although primary open-angle glaucoma is more common, primary angle-closure glaucoma (PACG) is more likely to result in irreversible blindness. By 2020, 5·3 million people worldwide will be blind because of PACG. The current standard care for PACG is a stepped approach of a combination of laser iridotomy surgery (to open the drainage angle) and medical treatment (to reduce intraocular pressure). If these treatments fail, glaucoma surgery (eg, trabeculectomy) is indicated. It has been proposed that, because the lens of the eye plays a major role in the mechanisms leading to PACG, early clear lens extraction will improve glaucoma control by opening the drainage angle. This procedure might reduce the need for drugs and glaucoma surgery, maintain good visual acuity, and improve quality of life compared with standard care.EAGLE aims to evaluate whether early lens extraction improves patient-reported, clinical outcomes, and cost-effectiveness, compared with standard care. EAGLE is a multicentre pragmatic randomized trial. All people presenting to the recruitment centres in the UK and east Asia with newly diagnosed PACG and who are at least 50 years old are eligible.The primary outcomes are EQ-5D, intraocular pressure, and incremental cost per quality adjusted life year (QALY) gained. Other outcomes are: vision and glaucoma-specific patient-reported outcomes, visual acuity, visual field, angle closure, number of medications, additional surgery (e.g., trabeculectomy), costs to the health services and patients, and adverse events.A single main analysis will be done at the end of the trial, after three years of follow-up. The analysis will be based on all participants as randomized (intention to treat). 400 participants (200 in each group) will be recruited, to have 90% power at 5% significance level to detect a difference in EQ-5D score between the two groups of 0·05, and a mean difference in intraocular pressure of 1·75 mm Hg. The study will have 80% power to detect a difference of 15% in the glaucoma surgery rate. ISRCTN44464607.
Evaluation of Different Power of Near Addition in Two Different Multifocal Intraocular Lenses
Unsal, Ugur; Baser, Gonen
2016-01-01
Purpose. To compare near, intermediate, and distance vision and quality of vision, when refractive rotational multifocal intraocular lenses with 3.0 diopters or diffractive multifocal intraocular lenses with 2.5 diopters near addition are implanted. Methods. 41 eyes of 41 patients in whom rotational +3.0 diopters near addition IOLs were implanted and 30 eyes of 30 patients in whom diffractive +2.5 diopters near addition IOLs were implanted after cataract surgery were reviewed. Uncorrected and corrected distance visual acuity, intermediate visual acuity, near visual acuity, and patient satisfaction were evaluated 6 months later. Results. The corrected and uncorrected distance visual acuity were the same between both groups (p = 0.50 and p = 0.509, resp.). The uncorrected intermediate and corrected intermediate and near vision acuities were better in the +2.5 near vision added intraocular lens implanted group (p = 0.049, p = 0.005, and p = 0.001, resp.) and the uncorrected near vision acuity was better in the +3.0 near vision added intraocular lens implanted group (p = 0.001). The patient satisfactions of both groups were similar. Conclusion. The +2.5 diopters near addition could be a better choice in younger patients with more distance and intermediate visual requirements (driving, outdoor activities), whereas the + 3.0 diopters should be considered for patients with more near vision correction (reading). PMID:27340560
Tan, Xuhua; Lin, Haotian; Lin, Zhuoling; Chen, Jingjing; Tang, Xiangchen; Luo, Lixia; Chen, Weirong; Liu, Yizhi
2016-03-01
The objective of this study was to investigate capsular outcomes 12 months after pediatric cataract surgery without intraocular lens implantation via qualitative classification and quantitative measurement.This study is a cross-sectional study that was approved by the institutional review board of Zhongshan Ophthalmic Center of Sun Yat-sen University in Guangzhou, China.Digital coaxial retro-illumination photographs of 329 aphakic pediatric eyes were obtained 12 months after pediatric cataract surgery without intraocular lens implantation. Capsule digital coaxial retro-illumination photographs were divided as follows: anterior capsule opening area (ACOA), posterior capsule opening area (PCOA), and posterior capsule opening opacity (PCOO). Capsular outcomes were qualitatively classified into 3 types based on the PCOO: Type I-capsule with mild opacification but no invasion into the capsule opening; Type II-capsule with moderate opacification accompanied by contraction of the ACOA and invasion to the occluding part of the PCOA; and Type III-capsule with severe opacification accompanied by total occlusion of the PCOA. Software was developed to quantitatively measure the ACOA, PCOA, and PCOO using standardized DCRPs. The relationships between the accurate intraoperative anterior and posterior capsulorhexis sizes and the qualitative capsular types were statistically analyzed.The DCRPs of 315 aphakic eyes (95.8%) of 191 children were included. Capsular outcomes were classified into 3 types: Type I-120 eyes (38.1%); Type II-157 eyes (49.8%); Type III-38 eyes (12.1%). The scores of the capsular outcomes were negatively correlated with intraoperative anterior capsulorhexis size (R = -0.572, P < 0.001), but no significant correlation with intraoperative posterior capsulorhexis size (R = -0.16, P = 0.122) was observed. The ACOA significantly decreased from Type I to Type II to Type III, the PCOA increased in size from Type I to Type II, and the PCOO increased from Type II to Type III (all P < 0.05).Capsular outcomes after pediatric cataract surgery can be qualitatively classified and quantitatively measured by acquisition, division, definition, and user-friendly software analyses of high-quality digital coaxial retro-illumination photographs.
Capsular Outcomes After Pediatric Cataract Surgery Without Intraocular Lens Implantation
Tan, Xuhua; Lin, Haotian; Lin, Zhuoling; Chen, Jingjing; Tang, Xiangchen; Luo, Lixia; Chen, Weirong; Liu, Yizhi
2016-01-01
Abstract The objective of this study was to investigate capsular outcomes 12 months after pediatric cataract surgery without intraocular lens implantation via qualitative classification and quantitative measurement. This study is a cross-sectional study that was approved by the institutional review board of Zhongshan Ophthalmic Center of Sun Yat-sen University in Guangzhou, China. Digital coaxial retro-illumination photographs of 329 aphakic pediatric eyes were obtained 12 months after pediatric cataract surgery without intraocular lens implantation. Capsule digital coaxial retro-illumination photographs were divided as follows: anterior capsule opening area (ACOA), posterior capsule opening area (PCOA), and posterior capsule opening opacity (PCOO). Capsular outcomes were qualitatively classified into 3 types based on the PCOO: Type I—capsule with mild opacification but no invasion into the capsule opening; Type II—capsule with moderate opacification accompanied by contraction of the ACOA and invasion to the occluding part of the PCOA; and Type III—capsule with severe opacification accompanied by total occlusion of the PCOA. Software was developed to quantitatively measure the ACOA, PCOA, and PCOO using standardized DCRPs. The relationships between the accurate intraoperative anterior and posterior capsulorhexis sizes and the qualitative capsular types were statistically analyzed. The DCRPs of 315 aphakic eyes (95.8%) of 191 children were included. Capsular outcomes were classified into 3 types: Type I—120 eyes (38.1%); Type II—157 eyes (49.8%); Type III—38 eyes (12.1%). The scores of the capsular outcomes were negatively correlated with intraoperative anterior capsulorhexis size (R = −0.572, P < 0.001), but no significant correlation with intraoperative posterior capsulorhexis size (R = −0.16, P = 0.122) was observed. The ACOA significantly decreased from Type I to Type II to Type III, the PCOA increased in size from Type I to Type II, and the PCOO increased from Type II to Type III (all P < 0.05). Capsular outcomes after pediatric cataract surgery can be qualitatively classified and quantitatively measured by acquisition, division, definition, and user-friendly software analyses of high-quality digital coaxial retro-illumination photographs. PMID:26962807
Intraocular lens based on double-liquid variable-focus lens.
Peng, Runling; Li, Yifan; Hu, Shuilan; Wei, Maowei; Chen, Jiabi
2014-01-10
In this work, the crystalline lens in the Gullstrand-Le Grand human eye model is replaced by a double-liquid variable-focus lens, the structure data of which are based on theoretical analysis and experimental results. When the pseudoaphakic eye is built in Zemax, aspherical surfaces are introduced to the double-liquid variable-focus lens to reduce the axial spherical aberration existent in the system. After optimization, the zoom range of the pseudoaphakic eye greatly exceeds that of normal human eyes, and the spot size on an image plane basically reaches the normal human eye's limit of resolution.
Nuzzi, Raffaele; Monteu, Francesca; Tridico, Federico
2017-01-01
Radial keratotomy is a refractive surgical technique, widely used in the 80s and early 90s to correct myopia and astigmatism, but now overcome by more recent laser techniques. Important consequences, often in patients with more than 45 years of age, are progressive hyperopic shift and/or an increase in corneal astigmatism, whose main cause seems to be an increase in the curvature radius of the central portion of the cornea. This seems to be due to radial keratotomy incisions - with the consequent need for cross-linking - intraocular pressure, and corneal biomechanical parameters. The authors propose phacoemulsification with a customized multifocal toric intraocular lens implantation to correct the induced shift and hyperopic astigmatism. A decent postoperative visual acuity was observed with good patient satisfaction. A specific protocol must be applied to optimize the correct diagnosis, presurgical evaluation and postsurgical outcomes that are to be maintained over time, without regressions.
Kweon, Eui Yong; Ahn, Min; Lee, Dong Wook; You, In Cheon; Kim, Min Jung; Cho, Nam Chun
2009-01-01
The purpose of this study is to report the features of operating microscope light-induced retinal phototoxic maculopathy after transscleral sutured posterior chamber intraocular lens (TSS PC-IOL) implantation. The charts of 118 patients who underwent TSS PC-IOL implantation surgery at Chonbuk National University Hospital (Jeonju, Korea) between March 1999 and February 2008 were retrospectively reviewed. Fourteen patients underwent combined 3-port pars plana vitrectomy and TSS PC-IOL implantation (vitrectomy group), and 104 patients underwent TSS PC-IOL implantation only (nonvitrectomy group). All surgeries were performed under the same coaxial illuminated microscope. All diagnoses were confirmed through careful fundus examination and fluorescein angiography (FA). Diagnoses of retinal phototoxic maculopathy were established in 10 (8.47%) of 118 TSS PC-IOL implantation cases. Phototoxic maculopathy occurred more frequently in the vitrectomy group than in the nonvitrectomy group (6/14 versus 4/104, respectively; P < 0.001, chi-square = 24.21). Affected patients reported decreased vision and were found to have coarse alterations of the retinal pigment epithelium (RPE). In 5 of the phototoxic maculopathy cases (50%), the visual acuity was 20/200 or worse. Operating microscope light-induced retinal phototoxic maculopathy can occur more frequently after TSS PC-IOL implantation than after casual cataract surgery, especially when TSS PC-IOL is combined with vitrectomy surgery. Surgeons should take precautions to prevent retinal phototoxicity after TSS PC-IOL implantation and vitrectomy.
Adaptive Calibration of Dynamic Accommodation—Implications for Accommodating Intraocular Lenses
Schor, Clifton M.; Bharadwaj, Shrikant R.
2009-01-01
PURPOSE When the aging lens is replaced with prosthetic accommodating intraocular lenses (IOLs), with effective viscoelasticities different from those of the natural lens, mismatches could arise between the neural control of accommodation and the biomechanical properties of the new lens. These mismatches could lead to either unstable oscillations or sluggishness of dynamic accommodation. Using computer simulations, we investigated whether optimal accommodative responses could be restored through recalibration of the neural control of accommodation. Using human experiments, we also investigated whether the accommodative system has the capacity for adaptive recalibration in response to changes in lens biomechanics. METHODS Dynamic performance of two accommodating IOL prototypes was simulated for a 45-year-old accommodative system, before and after neural recalibration, using a dynamic model of accommodation. Accommodating IOL I, a prototype for an injectable accommodating IOL, was less stiff and less viscous than the natural 45-year-old lens. Accommodating IOL II, a prototype for a translating accommodating IOL, was less stiff and more viscous than the natural 45-year-old lens. Short-term adaptive recalibration of dynamic accommodation was stimulated using a double-step adaptation paradigm that optically induced changes in neuromuscular effort mimicking responses to changes in lens biomechanics. RESULTS Model simulations indicate that the unstable oscillations or sluggishness of dynamic accommodation resulting from mismatches between neural control and lens biomechanics might be restored through neural recalibration. CONCLUSIONS Empirical measures reveal that the accommodative system is capable of adaptive recalibration in response to optical loads that simulate effects of changing lens biomechanics. PMID:19044245
Ammar, Hatem; Anbar, Mohamed; Abdellah, Marwa M
2017-01-01
Purpose To compare the efficacy and outcome of phakic toric implantable collamer lens (TICL) and refractive clear lens extraction with AcrySof Toric intraocular lens (TIOL) implantation for the treatment of myopic astigmatism. Patients and methods This study assessed eyes with myopic astigmatism >−1 D and ≤−4 D with a spherical equivalent >10 D or <10 D if the patients were unsuitable for corneal refractive surgery. These eyes were divided into group A, in which Visian Toric ICL™ Phakic TICL was implanted, and group B, which involved clear lens extraction with implantation of an AcrySof IQ toric SN60T3-9™ IOL. The outcome and complications were evaluated. Results This study enrolled 63 eyes of 38 patients with a follow-up period of at least 6 months. The mean postoperative spherical equivalent was −0.19±0.31 D in group A and −0.21±0.28 D in group B (P=0.69). The mean postoperative cylinder value was −0.46±0.53 D in group A and −0.32±0.41 D in group B (P=0.35). Postoperative cylinder was <1 D in 76.47% and 79.31% of eyes in groups A and B, respectively. The mean endothelial cell count was reduced by 4.32% in group A and by 5.32% in group B (P=0.003). The mean postoperative intraocular pressure increased insignificantly in group A (P=0.22) and reduced significantly in group B (P=0.004). The complication rate was 11.76% in group A and 6.90% in group B. Conclusion Both procedures showed predictable results and good visual results. However, the loss of accommodation and risk of retinal complications in the TIOL group suggest that the use of TICL for myopic astigmatism is a better choice in younger patients. PMID:28096654
Sugita, Tadasu; Tsunekawa, Taichi; Matsuura, Toshiyuki; Takayama, Kei; Yamamoto, Kentaro; Kachi, Shu; Ito, Yasuki; Ueno, Shinji; Nonobe, Norie; Kataoka, Keiko; Suzumura, Ayana; Iwase, Takeshi; Terasaki, Hiroko
2017-01-01
Ocular trauma is one of the leading causes of visual impairment worldwide. Because of the popularity of cataract surgeries, aged individuals with ocular trauma commonly have a surgical wound in their eyes. The purpose of this study was to evaluate the visual outcome of cases that were coincident with intraocular lens (IOL) ejection in the eyes with ruptured open-globe ocular injuries. Consecutive patients with open-globe ocular injuries were first reviewed. Patients’ characteristics, corrected distance visual acuities (CDVAs) over 3 years after the trauma, causes of injuries, traumatic wound patterns, and coexistence of retinal detachment were examined. The relationships between poor CDVA and the other factors, including the complications of crystalline lens and IOL ejection, were examined. A total of 105 eyes/patients [43 eyes with rupture, 33 with penetrating, 28 with intraocular foreign body (IOFB), and 1 with perforating injuries] were included. Rupture injuries were common in aged patients and were mostly caused by falls, whereas penetrating and IOFB injuries were common in young male patients. CDVAs of the eyes with rupture injuries were significantly worse than those of the eyes with penetrating or IOFB injuries. CDVA from more than 50% of the ruptured eyes resulted in no light perception or light perception to 20/500. CDVA of the ruptured eyes complicated by crystalline lens ejection was significantly worse than that of those complicated by IOL ejection. The wounds of the ruptured eyes complicated by IOL ejection were mainly located at the superior corneoscleral limbus, whereas those of the eyes complicated by crystalline lens ejection were located at the posterior sclera. There were significant correlations between poor CDVA and retinal detachment and crystalline lens ejection. These results proposed a new trend in the ocular injuries that commonly occur in aged patients; history of cataract surgery might affect the final visual outcome after open-globe ocular injuries. PMID:28107485
Kohnen, Thomas; Herzog, Michael; Hemkeppler, Eva; Schönbrunn, Sabrina; De Lorenzo, Nina; Petermann, Kerstin; Böhm, Myriam
2017-12-01
To evaluate visual performance after implantation of a quadrifocal intraocular lens (IOL). Setting: Department of Ophthalmology, Goethe University, Frankfurt, Germany. Twenty-seven patients (54 eyes) received bilateral implantation of the PanOptix IOL (AcrySof IQ PanOptixTM; Alcon Research, Fort Worth, Texas, USA) pre-enrollment. Exclusion criteria were previous ocular surgeries, corneal astigmatism of >1.5 diopter (D), ocular pathologies, or corneal abnormalities. Intervention or Observational Procedure(s): Postoperative examination at 3 months including manifest refraction; uncorrected visual acuity (UCVA) and distance-corrected visual acuity (DCVA) in 4 m, 80 cm, 60 cm, and 40 cm slit-lamp examination; defocus testing; contrast sensitivity (CS) under photopic and mesopic conditions; and a questionnaire on subjective quality of vision, optical phenomena, and spectacle independence was performed. At 3 months postoperatively, UCVA and DCVA in 4 m, 80 cm, 60 cm, and 40 cm (logMAR), defocus curves, CS, and quality-of-vision questionnaire results. Mean spherical equivalent was -0.04 ± 0.321 D 3 months postoperatively. Binocular UCVA at distance, intermediate (80 cm, 60 cm), and near was 0.00 ± 0.094 logMAR, 0.09 ± 0.107 logMAR, 0.00 ± 0.111 logMAR, and 0.01 ± 0.087 logMAR, respectively. Binocular defocus curve showed peaks with best visual acuity (VA) at 0.00 D (-0.07 logMAR) and -2.00 D (-0.02 logMAR). Visual performance of the PanOptix IOL showed good VA at all distances; particularly good intermediate VA (logMAR > 0.1), with best VA at 60 cm; and high patient satisfaction and spectacle independence 3 months postoperatively. Copyright © 2017 Elsevier Inc. All rights reserved.
Lambert, Scott R; Lynn, Michael J; Hartmann, E Eugenie; DuBois, Lindreth; Drews-Botsch, Carolyn; Freedman, Sharon F; Plager, David A; Buckley, Edward G; Wilson, M Edward
2014-06-01
The efficacy and safety of primary intraocular lens (IOL) implantation during early infancy is unknown. To compare the visual outcomes of patients optically corrected with contact lenses vs IOLs following unilateral cataract surgery during early infancy. The Infant Aphakia Treatment Study is a randomized clinical trial with 5 years of follow-up that involved 114 infants with unilateral congenital cataracts at 12 sites. A traveling examiner assessed visual acuity at age 4.5 years. Cataract surgery with or without primary IOL implantation. Contact lenses were used to correct aphakia in patients who did not receive IOLs. Treatment was determined through random assignment. HOTV optotype visual acuity at 4.5 years of age. The median logMAR visual acuity was not significantly different between the treated eyes in the 2 treatment groups (both, 0.90 [20/159]; P = .54). About 50% of treated eyes in both groups had visual acuity less than or equal to 20/200. Significantly more patients in the IOL group had at least 1 adverse event after cataract surgery (contact lens, 56%; IOL, 81%; P = .02). The most common adverse events in the IOL group were lens reproliferation into the visual axis, pupillary membranes, and corectopia. Glaucoma/glaucoma suspect occurred in 35% of treated eyes in the contact lens group vs 28% of eyes in the IOL group (P = .55). Since the initial cataract surgery, significantly more patients in the IOL group have had at least 1 additional intraocular surgery (contact lens, 21%; IOL, 72%; P < .001). There was no significant difference between the median visual acuity of operated eyes in children who underwent primary IOL implantation and those left aphakic. However, there were significantly more adverse events and additional intraoperative procedures in the IOL group. When operating on an infant younger than 7 months of age with a unilateral cataract, we recommend leaving the eye aphakic and focusing the eye with a contact lens. Primary IOL implantation should be reserved for those infants where, in the opinion of the surgeon, the cost and handling of a contact lens would be so burdensome as to result in significant periods of uncorrected aphakia. clinicaltrials.gov Identifier: NCT00212134
Makhotkina, Natalia Y; Dugrain, Vincent; Purchase, Daniel; Berendschot, Tos T J M; Nuijts, Rudy M M A
2018-02-01
To evaluate whether the outcome of negative dysphotopsia treatment by implantation of a Sulcoflex intraocular lens (IOL) can be understood using individual biometry and optical modeling data. University Eye Clinic, Maastricht University Medical Centre, Maastricht, the Netherlands. Retrospective case series. Patients with negative dysphotopsia were treated with supplementary implantation of a sulcus-fixated IOL. Preoperative and postoperative ray-tracing optical models of eyes with negative dysphotopsia were constructed in the Zemax Optic Studio program using individual biometric data. The relationship between biometric parameters, ray-tracing data, and the course of negative dysphotopsia was evaluated. The study comprised 8 patients (10 eyes). After surgery, negative dysphotopsia resolved completely in 6 eyes, partially in 2 eyes, and persisted in 2 eyes. There was no relationship between the course of negative dysphotopsia and age, IOL power, or individual biometry results other than a larger angle κ that was observed in 2 patients with persistent negative dysphotopsia after surgery. Preoperative ray-tracing models showed a decrease in light irradiance at the periphery relative to the center of visual field. After sulcus-fixated IOL implantation, this decrease partially resolved, in particular, for a small pupil aperture (P < .05), and it was more prominent in patients in whom negative dysphotopsia resolved completely than in those with partial or persistent negative dysphotopsia (P = .065 at 1.5 mm aperture). Of all individual biometry results, only angle κ showed a relationship with the course of negative dysphotopsia. In patient-specific optical modeling of sulcus-fixated IOL implantation, the increase in simulated light irradiance at the periphery was related to the course of negative dysphotopsia. Copyright © 2018 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Baïkoff, Georges; Bourgeon, Grégoire; Jodai, Horacio Jitsuo; Fontaine, Aline; Lellis, Fernando Viera; Trinquet, Laure
2005-04-01
To validate the theory that crystalline lens rise can be used as a safety criterion to prevent pigment dispersion in eyes with an Artisan phakic intraocular lens (IOL) (Ophtec BV). Monticelli Clinic, Marseilles, France. A comparative analysis of crystalline lens rise in 9 eyes with pigment dispersion and 78 eyes without dispersion was performed. All eyes had previous implantation of an Artisan IOL. Anterior segment imaging was done using an anterior chamber optical coherence tomography (AC OCT) prototype. Crystalline lens rise was defined by the distance between the anterior pole of the crystalline lens and the horizontal plane joining the opposite iridocorneal recesses. The study confirmed that crystalline lens rise can be considered a safety criterion for implantation of Artisan-type phakic IOLs. The higher the crystalline lens rise, the greater the risk for developing pigment dispersion in the area of the pupil. This complication occurred more frequently in hyperopic eyes than in myopic eyes. Results indicate there is little or no risk for pigment dispersion if the rise is less than 600 microm; 67% of eyes with a rise of 600 microm or more developed pupillary pigment dispersion. In some cases in which the IOL was loosely fixated, there was no traction on the iris root and dispersion was prevented or delayed. Crystalline lens rise should be considered a new safety criterion for Artisan phakic IOL implantation and should also be applied to other types of phakic IOLs. The distance remaining between the crystalline lens rise and a 600 microm theoretical safety level allows one to calculate how long the IOL can safely remain in the eye.
Ma, Shengsheng; Zheng, Dongjian; Lin, Ling; Meng, Fanjian; Yuan, Yonggang
2015-03-01
To compare vision quality following phacoemulsification cataract extraction and implantation of a Big Bag or Akreos Adapt intraocular lens (IOL) in patients diagnosed with high myopia complicated with cataract. This was a randomized prospective control study. The patients with high myopia. complicated with cataract, with axial length ≥ 28 mm, and corneal astigmatism ≤ 1D were enrolled and randomly divided into the Big Bag and Akreos Adapt IOL groups. All patients underwent phacoemulsification cataract extraction and lens implantation. At 3 months after surgery, intraocular high-order aberration was measured by a Tracey-iTrace wavefront aberrometer at a pupil diameter of 5 mm in an absolutely dark room and statistically compared between two groups. The images of the anterior segment of eyes were photographed with a Scheimpflug camera using Penta-cam three-dimensional anterior segment analyzer. The tilt and decentration of the IOL were calculated by Image-pro plus 6.0 imaging analysis software and statistically compared between two groups. In total, 127 patients (127 eyes), including 52 males and 75 females, were enrolled in this study. The total high-order aberration and coma in the Akreos Adapt group (59 eyes) were significantly higher compared with those in the Big Bag (P < 0.05). The clover and spherical aberration did not differ between the two groups (P > 0.05). The horizontal and vertical decentration were significantly smaller in the Big Bag lens group than in the Akreos Adapt group (both P < 0.05), whereas the tilt of IOL did not significantly differ between the two groups (P > 0.05). Both Big Bag and Akreos Adapt IOLs possess relatively good intraocular stability implanted in patients with high myopia. Compared with the Akreos Adapt IOL, the Big Bag IOL presents with smaller intraocular high-order aberration. Coma is the major difference between the two groups.
Intraocular lens employed for cataract surgery
NASA Astrophysics Data System (ADS)
Roszkowska, A. M.; Torrisi, L.
2014-04-01
The aim of this paper is to illustrate the techniques of cataract surgery with implantation of intraocular lenses and some physical properties of the used materials. The new technology, coupled with extensive experience and the studied cases, permits to increase the standardization and accuracy of the engravings, by reducing the use and handling of surgical instruments inside the eye. At present it is possible to replace the cataract with crystalline lenses based on biopolymers such as PMMA, silicone, acrylic hydrophilic and hydrophobic acrylic. These materials are increasingly able to replace the natural lens and to ensure the fully functional of the eye. The role of femtosecond lasers in cataract surgery, to assist or replace several aspects of the manual cataract surgery, are discussed.
The long term effect of an iris-supported lens on the endothelium.
Galin, M A; Dotson, R S; Obstbaum, S A; Tuberville, A W
1982-01-01
A retrospective study of 104 eyes that had iris-supported Sputnik intraocular lenses implanted and no surgery in the fellow eye and a separate series of 30 implanted eyes whose second eyes underwent surgery but did not receive implants disclosed that endothelial cell densities in the eyes with implants decreased immediately after surgery and then continued to decrease at the same rate as those of the control eyes. There was no sudden decrease in the endothelial cell counts during follow-up periods ranging from three to seven years. The main cause of large cell losses immediately after surgery, and possibly long-term corneal decompensation, was surgical manipulation rather than the presence of this style of intraocular lens.
[Laser magnetotherapy after cataract extraction with implantation of intraocular lens].
Maksimov, V Iu; Zakharova, N V; Maksimova, I S; Golushkov, G A; Evseev, S Iu
2002-01-01
Effects of low-intensive laser and alternating magnetic field on the course of the postoperative period were studied in patients with exudative reaction after extracapsular cataract extraction with implantation of intraocular lens (IOL). The results are analyzed for 148 eyes with early exudative reaction after IOL implantation (136 patients aged 42-75 years). The patients were observed for up to 6 months. The treatment efficiency was evaluated by the clinical picture of inflammatory reaction, visual acuity, and results of biochemical analysis of the lacrimal fluid (the ratio of lipid peroxidation products to antioxidants in cell membrane). The course of the postoperative period was more benign and recovery sooner in patients of the main group in comparison with the control.
Simulation of Blast Loading on an Ultrastructurally-based Computational Model of the Ocular Lens
2012-10-01
mechanisms of traumatic cataract forma - tion that may require cataract surgery (implantation of an intraocular lens (IOL)) are not well understood in...cornea and cutting through the iris and zonules. This was done by making a small incision with a diamond-head blade at the edge of the cornea and using
Anterior capsular rupture following blunt ocular injury
Gremida, Anas; Kassem, Iris; Traish, Aisha
2011-01-01
Summary A 10-year-old boy suffered a large, oblique anterior capsular tear following blunt injury to his right eye. The boy was followed daily for hyphema resolution and progressive traumatic cataract formation. After the hyphema had resolved, the lens was removed using an anterior approach and an intraocular lens was placed with excellent visual outcome. PMID:23362402
The effect of scleral search coil lens wear on the eye.
Murphy, P J; Duncan, A L; Glennie, A J; Knox, P C
2001-03-01
Scleral search coils are used to measure eye movements. A recent abstract suggests that the coil can affect the eye by decreasing visual acuity, increasing intraocular pressure, and damaging the corneal and conjunctival surface. Such findings, if repeated in all subjects, would cast doubt on the credibility of the search coil as a reliable investigative technique. The aim of this study was to reassess the effect of the scleral search coil on visual function. Six volunteer subjects were selected to undergo coil wear and baseline measurements were taken of logMAR visual acuity, non-contact tonometry, keratometry, and slit lamp examination. Four drops of 0.4% benoxinate hydrochloride were instilled before insertion of the lens by an experienced clinician. The lens then remained on the eye for 30 minutes. Measurements of the four ocular health parameters were repeated after 15 and 30 minutes of lens wear. The lens was then removed and the health of the eye reassessed. No obvious pattern of change was found in logMAR visual acuity, keratometry, or intraocular pressure. The lens did produce changes to the conjunctival and corneal surfaces, but this was not considered clinically significant. Search coils do not appear to cause any significant effects on visual function. However, thorough prescreening of subjects and post-wear checks should be carried out on all coil wearers to ensure no adverse effects have been caused.
The Significance of the Discordant Occurrence of Lens Tumors in Humans versus Other Species
Albert, Daniel M.; Phelps, Paul O.; Surapaneni, Krishna R.; Thuro, Bradley A.; Potter, Heather D.; Ikeda, Akihiro; Teixeira, Leandro B. C.; Dubielzig, Richard R.
2015-01-01
Purpose The purpose of this study was to determine in which species and under what conditions lens tumors occur. Design A review of data bases of available human and veterinary ocular pathological material and the previously reported literature. Participants Approximately 18,000 patients who had ocular surgical specimens submitted and studied at the University of Wisconsin School of Medicine and Public Health (UWSMPH) between 1920 and 2014 and 45,000 ocular veterinary cases from the Comparative Ocular Pathology Laboratory of Wisconsin (COPLOW) between 1983 and 2014. Methods Material in two major archived collections at the University of Wisconsin medical and veterinary schools were studied for occurrence of lens tumors. Tumor was defined as “a new growth of tissue characterized by progressive, uncontrolled proliferation of cells.” In addition, cases presented at 3 major eye pathology societies (Verhoeff-Zimmerman Ophthalmic Pathology Society, Eastern Ophthalmic Pathology Society, and The Armed Forces Institute of Pathology Ophthalmic Alumni Society) from 1975 through 2014 were reviewed. Finally, a careful search of the literature was carried out. Approval from the IRB to carry out this study was obtained. Main Outcome Measures The presence of tumors of the lens. Results The database search and literature review failed to find an example of a lens tumor in humans. In contrast, examples of naturally occurring lens tumors were found in cats, dogs, rabbits, and birds. 4.5% of feline intraocular and adnexal neoplasms (234/5153) in the veterinary school database were designated as feline ocular post-traumatic sarcoma (FOPTS), a tumor previously demonstrated to be of lens epithelial origin. Similar tumors were seen in rabbit eyes, a bird, and in a dog. All four species with lens tumors had a history of either ocular trauma or protracted uveitis. The literature search also revealed cases where lens tumors were induced in zebrafish, rainbow trout, hamsters, and mice, by carcinogenic agents (methylcholanthrene, thioacetamide), oncogenic viruses (SV40, HPV-16), and genetic manipulation. Conclusions Our results suggest that lens tumors do not occur in humans. In contrast, following lens capsule rupture, a lens tumor can occur in other species. We hypothesize that a genetic mechanism exists which prevents lens tumors in humans. PMID:26130328
Pandey, Suresh K; Werner, Liliana; Apple, David J; Kaskaloglu, Mahmut
2002-11-01
To report clinicopathologic and ultrastructural features of two opacified single-piece hydrophilic acrylic intraocular lenses (IOLs) explanted from a diabetic patient. Interventional case report with clinicopathologic correlation. A 64-year-old white female underwent phacoemulsification and implantation of a single-piece hydrophilic acrylic lens (SC60B-OUV; Medical Developmental Research, Inc., Clear Water, FL) in October 1998 in the left eye and in July 1999 in the right eye. The best-corrected visual acuity after surgery was 20/60 in the left eye and 20/50 in the right eye. The patient had a marked decrease in visual acuity in June 2000 as a result of a milky, white opalescence of both lenses. Intraocular lens explantation and exchange was performed in both eyes and the explanted IOLs were submitted to our center for detailed pathologic, histochemical, and ultrastructural evaluation. They were stained with alizarin red and the von Kossa method for calcium, and also underwent scanning electron microscopy and energy dispersive radiograph spectroscopy to ascertain the nature of the deposits leading to opacification. Documentation of calcium deposits confirmed by histochemical stains and surface analyses. Opacification of the IOL was found to be the cause of decreased visual acuity. The opacification involved both the IOL optic and the haptics in the left eye and was confined to the IOL optic in the right eye. Histochemical and ultrastructural analyses revealed that the opacity was caused by deposition of calcium and phosphate within the lens optic and haptics. There are two features that distinguish this case from those reported earlier. This is the first clinicopathologic report of lens opacification that has involved completely the lens optic and the haptics. Second, these two explanted IOLs document the first bilateral case. This process of intraoptic and haptic opacification represents dystrophic calcification of unknown cause. Diabetic patients appear to be more severely and more often affected by lens opacification. Long-term follow-up of diabetic patients implanted with this IOL design should be maintained by surgeons and manufacturers.
Tomás-Juan, Javier; Murueta-Goyena Larrañaga, Ane
2015-01-01
Presbyopia occurs in the aging eye due to changes in the ciliary muscle, zonular fibers, crystalline lens, and an increased lens sclerosis. As a consequence, the capacity of accommodation decreases, which hampers to focus near objects. With the aim of restoring near vision, different devices that produce multiple focuses have been developed and introduced. However, these devices are still unable to restore accommodation. In order to achieve that goal, dual-optic accommodating Intraocular Lenses have been designed, whose anterior optic displaces axially to increase ocular power, and focus near objects. Although dual-optic accommodating IOLs are relatively new, their outcomes are promising, as they provide large amplitudes of accommodation and a greater IOL displacement than single-optic accommodating IOLs. The outcomes show comfortable near vision, higher patients' satisfaction rates, and minimal postoperative complications like Posterior Capsular Opacification and Anterior Capsular Opacification, due to their design and material. Copyright © 2014. Published by Elsevier Espana.
Verdaguer, Paula; Gris, Oscar; Casaroli-Marano, Ricardo P; Elies, Daniel; Muñoz-Gutierrez, Gerardo; Güell, Jose L
2015-08-01
To describe a case of hydrophilic intraocular lens (IOL) opacification based on IOL analysis after Descemet stripping automated endothelial keratoplasty. A 60-year-old woman had uneventful phacoemulsification after the implantation of a hydrophilic IOL (Akreos-Adapt; Bausch & Lomb) into both eyes. Because of postoperative corneal decompensation in the right eye, 2 Descemet stripping automated endothelial keratoplasty operations were performed within 1 year. After the second procedure, the graft was not well attached, requiring an intracameral injection of air on day 3. After 1 year, opacification was observed on the superior 2/3 of the anterior surface of the IOL, along with a significant decrease in visual acuity. The IOL was explanted 6 months after the opacification. Environmental scanning electron microscopy followed by x-ray microanalysis revealed an organic biofilm on the surface of the IOL. To our knowledge, this is the first reported case in which the material deposited on the lens is organic rather than calcific.
Vilar, César; Hida, Wilson Takashi; de Medeiros, André Lins; Magalhães, Klayny Rafaella Pereira; de Moraes Tzelikis, Patrick Frensel; Chaves, Mario Augusto Pereira Dias; Motta, Antônio Francisco Pimenta; Carricondo, Pedro Carlos; Alves, Milton Ruiz; Nosé, Walton
2017-01-01
Purpose To compare visual outcomes and performance between bilateral implantation of a diffractive trifocal intraocular lens (IOL) Acrysof®PanOptix® TFNT00 and blended implantation of two different near add power bifocal IOLs: Acrysof® Restor® SV25T0 in dominant eye and Acrysof® Restor® SN6AD1 in the nondominant eye. Methods This prospective, nonrandomized, consecutive and comparative study assessed 20 patients (40 eyes) who had bilateral cataract surgery performed using the IOLs described. Patients were divided into groups, bilateral trifocal implant and blended implant. Evaluation included measurement of binocular uncorrected and corrected distance visual acuity at 4 m (UDVA, CDVA) and uncorrected intermediate (60 cm) and near (at 40 cm) visual acuity; contrast sensitivity (CS) and visual defocus curve. Results Postoperative CDVA comparison showed no statistical significance between groups. UDVA was significantly better in the trifocal groups. Under photopic conditions, the trifocal group had better CS in higher frequencies with and without glare. The binocular defocus curve demonstrated a trifocal behavior in both groups, with the bilateral trifocal group exhibiting better performance for intermediate vision. Conclusion Both lens combinations were able to provide good near, intermediate and distance vision, with the trifocal group showing significantly better performance at intermediate distances and better CS under photopic conditions. PMID:28814826
Yan, Pi-song; Zhang, Zhen-ping; Lin, Hao-tian; Wu, Wen-jie; Bai, Ling
2009-09-01
To investigate quantitative changes of the anterior segment configuration after clear corneal incision phacoemulsification and foldable intraocular lens (IOL) implantation with slit-lamp-adapted optical coherence tomography (SL-OCT). In prospective consecutive case series, clear corneal incision phacoemulsification and foldable intraocular lens implantation were performed in 44 eyes of 40 patients. The changes of the anterior segment configuration were performed by SL-OCT before and 1 day, 1 week, 2 weeks and 1 month after surgery. SPSS 16.0 software was used to analyze statistical difference. For all patients, the central corneal thickness (CCT) and the incisional corneal thickness (ICT) increased significantly 1 day after surgery (CCT increased 99.59 microm, ICT increased 234.57 microm; P = 0.490). At 1 month, the CCT almost had returned to baseline, but the ICT had been thicker about 19.25 microm than baseline(P = 0.001). The measurements of ACD, AOD500, AOD750, TISA500, TISA750 also increased significantly 1 day after surgery. Although the ACD had no changes within 2 weeks (all P < 0.05), it had been not stable. The changes of the width of the anterior chamber had been stable in the early period after surgery (all P > 0.05). The SL-OCT could impersonality and quantificationally evaluate the anterior segment changes induced by cataract surgery.
Vajpayee, R B; Angra, S K; Honavar, S G
1994-04-15
Over a period of two years we performed combined penetrating keratoplasty, cataract extraction, and intraocular lens implantation in seven children between the ages of 2 and 12 years old. The interval between trauma and the surgery varied from six weeks to six months (3.5 +/- 1.6 months, mean +/- SD). All of the patients had undergone primary repair of corneal perforation. Fresh corneas preserved in McCarey-Kaufman medium were used. The graft size was 7.5 mm with 0.5 mm disparity. Posterior chamber polymethylmethacrylate C-loop lenses were used in all cases. The surgeon's average postkeratoplasty keratometry was used in the calculation of intraocular lens power. The follow-up period ranged from nine to 36 months (18 +/- 9.1 months, mean +/- SD). Six grafts remained clear at the final follow-up. The visual acuity ranged from 20/40 to 20/200 with final astigmatism ranging from 0.5 diopter to 2.0 diopters. One patient developed a retinal detachment 12 months after surgery, which was successfully reattached. One patient, who had preoperative corneal vascularization, had graft rejection, which was treated medically. Our limited series suggests that the triple ocular procedure is a good choice for the treatment of corneolenticular trauma in children. The proper postoperative treatment includes vigorous antiamblyopia therapy and Nd:YAG laser treatment of after-cataracts.
Iijima, Ayaka; Shimizu, Kimiya; Yamagishi, Mayumi; Kobashi, Hidenaga; Igarashi, Akihito; Kamiya, Kazutaka
2016-12-01
To evaluate the subjective intraocular forward scattering and quality of vision after posterior chamber phakic intraocular lens with a central hole (Hole ICL, STAAR Surgical) implantation. We prospectively examined 29 eyes of 29 consecutive patients (15 men and 14 women; ages, 37.2 ± 8.8 years) undergoing Hole ICL implantation. We assessed the values of the logarithmic straylight value [log (s)] using a straylight meter (C-Quant ™ , Oculus) preoperatively and 3 months postoperatively. The patients completed a questionnaire detailing symptoms on a quantitative grading scale (National Eye Institute Refractive Error Quality of Life Instrument-42; NEI RQL-42) 3 months postoperatively. We compared the preoperative and postoperative values of the log(s) and evaluated the correlation of these values with patient subjective symptoms. The mean log(s) was not significantly changed, from 1.07 ± 0.20 preoperatively, to 1.06 ± 0.17 postoperatively (Wilcoxon signed-rank test, p = 0.641). There was a significant correlation between the preoperative and postoperative log(s) (Spearman's correlation coefficient r = 0.695, p < 0.001). The postoperative log(s) was significantly associated with the scores of glare in the questionnaire (Spearman's correlation coefficient r = -0.575, p = 0.017). According to our experience, Hole ICL implantation does not induce a significant additional change in the subjective intraocular forward scattering. The symptom of glare after Hole ICL implantation was significantly correlated with the postoperative intraocular forward scattering in relation to the preoperative one. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Rabbits' eye globe sonographic biometry.
Toni, Maria Carolina; Meirelles, Adriana Érica Wilkes Burton; Gava, Fábio Nelson; Camacho, Aparecido Antônio; Laus, José Luiz; Canola, Júlio Carlos
2010-11-01
To measure intraocular structures in New Zealand White breed rabbits (Oryctolagus cuniculus Linnaeus, 1758) using A-mode and B-mode ultrasound with a 20 MHz transducer. In this study, the eyes of 15 rabbits were evaluated for determination of intraocular measurements using an ophthalmic ultrasound unit able to operate in both A and B-modes. The distances from the cornea to the anterior capsule of the lens (D1), from the anterior capsule of the lens to the posterior capsule of the lens (D2), from the posterior capsule of the lens to the retina (D3) and the complete length of the eye, which corresponds to the distance from the cornea to the retina (D4) were taken. The mean values obtained were 2.70 mm (± 0.22 mm) for D1, 7.32 mm (± 0.40 mm) for D2, 7.10 mm (± 0.45 mm) for D3 and 17.12 mm (± 0.41 mm) for D4. Statistical analyses using the Student's t-test showed that there were no differences between the eyes. The study was feasible without the need of pharmacological restraint and yielded normal mean values for ocular sonographic biometry in rabbits. © 2010 American College of Veterinary Ophthalmologists.
Simulation of Blast Loading on an Ultrastructurally-based Computational Model of the Ocular Lens
2015-10-01
cells) is stressed by the passing shock wave. Traumatic cataract can result in a partially or fully clouded lens, complete dislo- cation of the lens...penetration by Intra-Ocular Foreign Bodies (IOFBs), but also shock propagation and solid-fluid interaction be- tween the lens and vitreous and aqueous...1040-8738. doi: 10.1097/ICU.0b013e3283140e98. T.Y. Wong, M.B. Seet, and C.L. Ang. Eye injuries in twentieth century warfare: A historical perspective. Survey of Ophthalmology, 41(6):433–459, MAY-JUN 1997. ISSN 0039-6257. i
Objective measurement of accommodative biometric changes using ultrasound biomicroscopy
Ramasubramanian, Viswanathan; Glasser, Adrian
2015-01-01
PURPOSE To demonstrate that ultrasound biomicroscopy (UBM) can be used for objective quantitative measurements of anterior segment accommodative changes. SETTING College of Optometry, University of Houston, Houston, Texas, USA. DESIGN Prospective cross-sectional study. METHODS Anterior segment biometric changes in response to 0 to 6.0 diopters (D) of accommodative stimuli in 1.0 D steps were measured in eyes of human subjects aged 21 to 36 years. Imaging was performed in the left eye using a 35 MHz UBM (Vumax) and an A-scan ultrasound (A-5500) while the right eye viewed the accommodative stimuli. An automated Matlab image-analysis program was developed to measure the biometry parameters from the UBM images. RESULTS The UBM-measured accommodative changes in anterior chamber depth (ACD), lens thickness, anterior lens radius of curvature, posterior lens radius of curvature, and anterior segment length were statistically significantly (P < .0001) linearly correlated with accommodative stimulus amplitudes. Standard deviations of the UBM-measured parameters were independent of the accommodative stimulus demands (ACD 0.0176 mm, lens thickness 0.0294 mm, anterior lens radius of curvature 0.3350 mm, posterior lens radius of curvature 0.1580 mm, and anterior segment length 0.0340 mm). The mean difference between the A-scan and UBM measurements was −0.070 mm for ACD and 0.166 mm for lens thickness. CONCLUSIONS Accommodating phakic eyes imaged using UBM allowed visualization of the accommodative response, and automated image analysis of the UBM images allowed reliable, objective, quantitative measurements of the accommodative intraocular biometric changes. PMID:25804579
CROFT, MARY ANN; HEATLEY, GREGG; MCDONALD, JARED P.; KATZ, ALEXANDER; KAUFMAN, PAUL L.
2016-01-01
Purpose To elucidate the dynamic accommodative movements of the lens capsule, posterior lens and the strand that attaches to the posterior vitreous zonule insertion zone and posterior lens equator (PVZ INS-LE), and their age-related changes. Methods Twelve human subjects (ages 19–65 years) and twelve rhesus monkeys (ages 6–27 years) were studied. Accommodation was induced pharmacologically (humans) or by central electrical stimulation (monkeys). Ultrasound biomicroscopy was used to image intraocular structures in both species. Surgical procedures and contrast agents were utilized in the monkey eyes to elucidate function and allow visualization of the intraocular accommodative structures. Results Human: The posterior pole of the lens moves posteriorly during accommodation in proportion to accommodative amplitude and ciliary muscle movement. Monkey: Similar accommodative movements of the posterior lens pole were seen in the monkey eyes. Following extracapsular lens extraction (ECLE), the central capsule bows backward during accommodation in proportion to accommodative amplitude and ciliary muscle movement, while the peripheral capsule moves forward. During accommodation the ciliary muscle moved forward by ~1.0 mm, pulling forward the vitreous zonule and the PVZ INS-LE structure. During the accommodative response the PVZ INS-LE structure moved forward when the lens was intact and when the lens substance and capsule were removed. In both the monkey and the human eyes these movements declined with age. Conclusions The accommodative shape change of the central capsule may be due to the elastic properties of the capsule itself. For these capsule/lens accommodative posterior movements to occur, the vitreous face must either allow for it or facilitate it. The PVZ INS-LE structure may act as a “strut” to the posterior lens equator (pushing the lens equator forward) and thereby facilitate accommodative forward lens equator movement and lens thickening. The age-related posterior restriction of the ciliary muscle, vitreous zonule and the PVZ-INS LE structure dampens the accommodative lens shape change. Future descriptions of the accommodative mechanism, and approaches to presbyopia therapy, may need to incorporate these findings. PMID:26769326
2011-01-01
Background Glaucoma is the leading cause of irreversible blindness. Although primary open-angle glaucoma is more common, primary angle-closure glaucoma (PACG) is more likely to result in irreversible blindness. By 2020, 5·3 million people worldwide will be blind because of PACG. The current standard care for PACG is a stepped approach of a combination of laser iridotomy surgery (to open the drainage angle) and medical treatment (to reduce intraocular pressure). If these treatments fail, glaucoma surgery (eg, trabeculectomy) is indicated. It has been proposed that, because the lens of the eye plays a major role in the mechanisms leading to PACG, early clear lens extraction will improve glaucoma control by opening the drainage angle. This procedure might reduce the need for drugs and glaucoma surgery, maintain good visual acuity, and improve quality of life compared with standard care. EAGLE aims to evaluate whether early lens extraction improves patient-reported, clinical outcomes, and cost-effectiveness, compared with standard care. Methods/Design EAGLE is a multicentre pragmatic randomized trial. All people presenting to the recruitment centres in the UK and east Asia with newly diagnosed PACG and who are at least 50 years old are eligible. The primary outcomes are EQ-5D, intraocular pressure, and incremental cost per quality adjusted life year (QALY) gained. Other outcomes are: vision and glaucoma-specific patient-reported outcomes, visual acuity, visual field, angle closure, number of medications, additional surgery (e.g., trabeculectomy), costs to the health services and patients, and adverse events. A single main analysis will be done at the end of the trial, after three years of follow-up. The analysis will be based on all participants as randomized (intention to treat). 400 participants (200 in each group) will be recruited, to have 90% power at 5% significance level to detect a difference in EQ-5D score between the two groups of 0·05, and a mean difference in intraocular pressure of 1·75 mm Hg. The study will have 80% power to detect a difference of 15% in the glaucoma surgery rate. Trial Registration: ISRCTN44464607. PMID:21605352
Iizuka, Megumi; Gorfinkel, John; Mandelcorn, Mark; Lam, Wai-Ching; Devenyi, Robert; Markowitz, Samuel N
2007-12-01
The most desirable effect following cataract surgery in the presence of age-related macular degeneration (AMD) is to obtain an improvement in distance resolution acuity, and the only optical solution to this is the use of telescopic magnification. The purpose of the study was to develop and verify the clinical utility of inducing low-grade telescopic magnification (<33%) at the time of cataract surgery by the choice of an appropriate intraocular lens power and spectacle glasses in patients with AMD and cataract. The design was a prospective, nonrandomized, interventional case series involving 6 patients aged 74-86 (mean 80; SD 4) years with AMD and cataract. Participants were males and females, equal in number, who had visual acuity of less than 20/400 in the weaker eye. Standard cataract surgery was performed in the weaker eye. The power of the intraocular lens was derived from the reduced Gullstrand model of the eye in such a way that at the intraocular lens plane a minus lens was created, which, together with a plus lens in matching glasses, formed a Galilean telescopic system with magnification of up to 33%. Outcome measures were visual acuity, contrast sensitivity, and activities of daily living (ADL) scores. The mean power of the implanted intraocular lenses was 6.31 (SD 2.42) diopters and, according to the theoretical derivations, achieved magnification between 20% and 30% (mean 26%; SD 4.92%). Visual acuity improved for the group from a mean of 20/525 (logMAR 1.48; SD 0.13) to a mean of 20/290 (logMAR 1.20; SD 0.21). Contrast sensitivity improved significantly (p < 0.001) only in the lower spatial frequencies. Postoperatively, ADL scores improved significantly in all patients except one. At the end of the follow-up period, 3 patients reported that they would like to proceed with similar surgery for the other eye. An optimal surgical telescopic device based on low-grade telescopic magnification may improve functional vision for usage in all tasks in AMD patients. All patients from this study were satisfied following surgery and viewed study outcomes as positive and beneficial, and some patients responded with enthusiasm. Surgeons are encouraged to use this modified technique of cataract surgery in low-vision patients with AMD and cataract.
Code of Federal Regulations, 2011 CFR
2011-10-01
... or contact lenses furnished subsequent to each cataract surgery with insertion of an intraocular lens; and (3) Leg, arm, back, and neck braces, and artificial legs, arms, and eyes, including replacements...
Cheng, H W; Jeng, B M; Chen, C Y; Huang, H Y; Chiou, J C; Luo, C H
2013-01-01
This paper proposed a wireless power harvesting system with micro-electro-mechanical-systems (MEMS) fabrication for noninvasive intraocular pressure (IOP) measurement on soft contact lens substructure. The power harvesting IC consists of a loop antenna, an impedance matching network and a rectifier. The proposed IC has been designed and fabricated by CMOS 0.18 um process that operates at the ISM band of 5.8 GHz. The antenna and the power harvesting IC would be bonded together by using flip chip bonding technologies without extra wire interference. The circuit utilized an impedance transformation circuit to boost the input RF signal that improves the circuit performance. The proposed design achieves an RF-to-DC conversion efficiency of 35% at 5.8 GHz.
Intraocular lens design for treating high myopia based on individual eye model
NASA Astrophysics Data System (ADS)
Wang, Yang; Wang, Zhaoqi; Wang, Yan; Zuo, Tong
2007-02-01
In this research, we firstly design the phakic intraocular lens (PIOL) based on individual eye model with optical design software ZEMAX. The individual PIOL is designed to correct the defocus and astigmatism, and then we compare the PIOL power calculated from the individual eye model with that from the experiential formula. Close values of PIOL power are obtained between the individual eye model and the formula, but the suggested method has more accuracy with more functions. The impact of PIOL decentration on human eye is evaluated, including rotation decentration, flat axis decentration, steep axis decentration and axial movement of PIOL, which is impossible with traditional method. To control the PIOL decentration errors, we give the limit values of PIOL decentration for the specific eye in this study.
Al-Otaibi, Abdullah G.; Al-Qahtani, Elham S.
2011-01-01
Snowflake degeneration is a slow progressive opacification of polymethyl methacrylate (PMMA) intraocular lenses (IOLs). This late postoperative complication can occur a decade or later after implantation. The deposits are composed of IOL materials that tend to aggregate centrally. There is a relative paucity of the literature on snowflake degeneration of IOLs. Symptoms can range from mild visual disturbance to significant loss of visual acuity. In cases of opacification after IOL implantation, the different diagnosis should include snowflake degeneration to prevent surgical intervention such as lens exchange or explantation unless clinically warranted. We report a case of late optical opacification of a PMMA IOL, the clinical diagnosis and treatment that increased best corrected vision. PMID:23960977
Pentacam Scheimpflug quantitative imaging of the crystalline lens and intraocular lens.
Rosales, Patricia; Marcos, Susana
2009-05-01
To implement geometrical and optical distortion correction methods for anterior segment Scheimpflug images obtained with a commercially available system (Pentacam, Oculus Optikgeräte GmbH). Ray tracing algorithms were implemented to obtain corrected ocular surface geometry from the original images captured by the Pentacam's CCD camera. As details of the optical layout were not fully provided by the manufacturer, an iterative procedure (based on imaging of calibrated spheres) was developed to estimate the camera lens specifications. The correction procedure was tested on Scheimpflug images of a physical water cell model eye (with polymethylmethacrylate cornea and a commercial IOL of known dimensions) and of a normal human eye previously measured with a corrected optical and geometrical distortion Scheimpflug camera (Topcon SL-45 [Topcon Medical Systems Inc] from the Vrije University, Amsterdam, Holland). Uncorrected Scheimpflug images show flatter surfaces and thinner lenses than in reality. The application of geometrical and optical distortion correction algorithms improves the accuracy of the estimated anterior lens radii of curvature by 30% to 40% and of the estimated posterior lens by 50% to 100%. The average error in the retrieved radii was 0.37 and 0.46 mm for the anterior and posterior lens radii of curvature, respectively, and 0.048 mm for lens thickness. The Pentacam Scheimpflug system can be used to obtain quantitative information on the geometry of the crystalline lens, provided that geometrical and optical distortion correction algorithms are applied, within the accuracy of state-of-the art phakometry and biometry. The techniques could improve with exact knowledge of the technical specifications of the instrument, improved edge detection algorithms, consideration of aspheric and non-rotationally symmetrical surfaces, and introduction of a crystalline gradient index.
The effect of scleral search coil lens wear on the eye
Murphy, P.; Duncan, A.; Glennie, A.; Knox, P.
2001-01-01
BACKGROUND/AIM—Scleral search coils are used to measure eye movements. A recent abstract suggests that the coil can affect the eye by decreasing visual acuity, increasing intraocular pressure, and damaging the corneal and conjunctival surface. Such findings, if repeated in all subjects, would cast doubt on the credibility of the search coil as a reliable investigative technique. The aim of this study was to reassess the effect of the scleral search coil on visual function. METHODS—Six volunteer subjects were selected to undergo coil wear and baseline measurements were taken of logMAR visual acuity, non-contact tonometry, keratometry, and slit lamp examination. Four drops of 0.4% benoxinate hydrochloride were instilled before insertion of the lens by an experienced clinician. The lens then remained on the eye for 30 minutes. Measurements of the four ocular health parameters were repeated after 15 and 30 minutes of lens wear. The lens was then removed and the health of the eye reassessed. RESULTS—No obvious pattern of change was found in logMAR visual acuity, keratometry, or intraocular pressure. The lens did produce changes to the conjunctival and corneal surfaces, but this was not considered clinically significant. CONCLUSION—Search coils do not appear to cause any significant effects on visual function. However, thorough prescreening of subjects and post-wear checks should be carried out on all coil wearers to ensure no adverse effects have been caused. PMID:11222341
Vision in semi-aquatic snakes: Intraocular morphology, accommodation, and eye: Body allometry
NASA Astrophysics Data System (ADS)
Plylar, Helen Bond
Vision in vertebrates generally relies on the refractive power of the cornea and crystalline lens to facilitate vision. Light from the environment enters the eye and is refracted by the cornea and lens onto the retina for production of an image. When an animal with a system designed for air submerges underwater, the refractive power of the cornea is lost. Semi-aquatic animals (e.g., water snakes, turtles, aquatic mammals) must overcome this loss of corneal refractive power through visual accommodation. Accommodation relies on change of the position or shape of the lens to change the focal length of the optical system. Intraocular muscles and fibers facilitate lenticular displacement and deformation. Snakes, in general, are largely unstudied in terms of visual acuity and intraocular morphology. I used light microscopy and scanning electron microscopy to examine differences in eye anatomy between five sympatric colubrid snake species (Nerodia cyclopion, N. fasciata, N. rhombifer, Pantherophis obsoletus, and Thamnophis proximus) from Southeast Louisiana. I discovered previously undescribed structures associated with the lens in semi-aquatic species. Photorefractive methods were used to assess refractive error. While all species overcame the expected hyperopia imposed by submergence, there was interspecific variation in refractive error. To assess scaling of eye size with body size, I measure of eye size, head size, and body size in Nerodia cyclopion and N. fasciata from the SLU Vertebrate Museum. In both species, body size increases at a significantly faster rate than head size and eye size (negative allometry). Small snakes have large eyes relative to body size, and large snakes have relatively small eyes. There were interspecific differences in scaling of eye size with body size, where N. fasciata had larger eye diameter, but N. cyclopion had longer eyes (axial length).
Design considerations of a real-time clinical confocal microscope
NASA Astrophysics Data System (ADS)
Masters, Barry R.
1991-06-01
A real-time clinical confocal light microscope provides the ophthalmologist with a new tool for the observation of the cornea and the ocular lens. In addition, the ciliary body, the iris, and the sclera can be observed. The real-time light microscopic images have high contrast and resolution. The transverse resolution is about one half micron and the range resolution is one micron. The following observations were made with visible light: corneal epithelial cells, wing cells, basal cells, Bowman's membrane, nerve fibers, basal lamina, fibroblast nuclei, Descemet's membrane, endothelial cells. Observation of the in situ ocular lens showed lens capsule, lens epithelium, lens fibrils, the interior of lens fibrils. The applications of the confocal microscope include: eye banking, laser refractive surgery, observation of wound healing, observation of the iris, the sciera, the ciliary body, the ocular lens, and the intraocular lens. Digital image processing can produce three-dimensional reconstructions of the cornea and the ocular lens.
Linz, K; Auffarth, G U; Kretz, F T A
2014-08-01
Residual refractive errors, especially high-grade astigmatism after penetrating keratoplasty, often lead to a significant loss of vision. If high anismetropia could not be corrected with glasses or contact lenses, different kinds of surgical procedures are available for visual rehabilitation (intraocular lens exchange, astigmatic keratotomy, Excimer laser treatment, intrastromal corneal ring segment implantation and additive intraocular lens implantation). Toric add-on IOLs are especially designed for sulcus implantation and correcting high astigmatism in pseudophakic eyes. All toric IOLs are individually manufactured according to subjective refraction and biometry. Depending on the underlying manufacturer high-grade astigmatism can be corrected with a cylindrical power up to + 30.0 D. A 74-year-old patient presented with endothelial decompensation and an uncorrected distance visual acuity (UDVA) of 1.0 logMAR for penetrating keratoplasty on the right eye due to a Fuchs endothelial dystrophy. Postoperatively, the uncorrected distance visual acuity improved to 0.8 logMAR, with pinhole correction to 0.5 logMAR. After removing the sutures a high and irregular corneal astigmatism of 21.0 D was found. The corrected distance visual acuity (CDVA) with a refraction of + 5.5 D sph, - 21.0 D cyl 90° was 0.24 logMAR. Therefore an individually manufactured toric additive intraocular lens of + 25.0 D cylindrical and - 18.0 D spherical power for sulcus implantation was chosen and implanted uneventfully. Eight months after surgery refractive astigmatism was reduced significantly to - 0.75 D with an UDVA of 0.08 logMAR and a CDVA of 0.02 logMAR. During the 8-months follow-up period the additive IOL remained centered and no IOL rotation could be observed. Toric add-on IOLs are a safe and successful method for reducing high astigmatism and anisometropia after penetrating keratoplasty. One of the main advantages is the reversibility of the procedure by an explantation of the IOL. Georg Thieme Verlag KG Stuttgart · New York.
Jiang, Yongxiang; Lu, Yi
2015-01-01
Aim The aim of this study was to evaluate the long-term visual outcomes and factors affecting visual results in children undergoing secondary intraocular lens (IOL) implantation following primary congenital cataract extraction. Methods Children with congenital cataracts who underwent secondary IOL implantation for aphakia at the Eye and ENT Hospital of Fudan University between January 1, 2001, and December 31, 2007, were retrospectively reviewed. One eye was randomly selected in children with bilateral cataracts. Laterality, type of cataract (total or partial opacity), sex, age at primary and secondary surgeries, visual axis opacity (VAO), compliance with amblyopia therapy, postoperative ocular complications, refractive error, ocular alignment, and best corrected visual acuity (BCVA) at last follow-up were recorded; potential factors that might have affected the visual results were evaluated. Results Seventy-six bilateral and 34 unilateral congenital cataract cases were analyzed; the mean ages of the children were 12.70±5.06 and 12.50±2.71 years at final follow-up, the mean follow-up periods from IOL implantation were 94.93±24.22 and 109.09±18.89 months, and the mean BCVA (Log MAR) values were 0.51±0.37 and 1.05±0.46, respectively. Final BCVA after secondary IOL implantation was significantly associated with laterality, type of cataract, age at primary cataract extraction, compliance with amblyopia therapy, and refractive correction after surgery. No significant associations were found between BCVA and sex, age at secondary IOL implantation, VAO, or other ocular complications. The most common ocular complications were VAO and elevated intraocular pressure after surgery. There were no other complications, with the exception of one eye with IOL dislocation. Conclusions The results indicate that the important determinants of long-term visual outcomes in children with congenital cataracts undergoing secondary IOL implantation are laterality, cataract type, age at initial cataract extraction, compliance with amblyopia therapy, and refractive error. PMID:26230501
Wolter, J R
1983-10-01
A Sputnik lens implant removed after five years because of bullous keratopathy exhibits a dense covering of its Supramid anterior staves with large foreign body giant cells, while its Prolene loops and Polymethylmethacrylate optics have attracted only few of these cell units. The glass-membrane-like component of the reactive membrane also shows significant differences on the different parts of this implant. The use of observation of the components of reactive membranes on lens implants as indicators of toleration in the eye is suggested.
42 CFR 410.36 - Medical supplies, appliances, and devices: Scope.
Code of Federal Regulations, 2010 CFR
2010-10-01
... eyeglasses or conventional contact lenses furnished after each cataract surgery during which an intraocular lens is inserted. (3) Leg, arm, back, and neck braces and artificial legs, arms, and eyes, including...
42 CFR 410.36 - Medical supplies, appliances, and devices: Scope.
Code of Federal Regulations, 2011 CFR
2011-10-01
... eyeglasses or conventional contact lenses furnished after each cataract surgery during which an intraocular lens is inserted. (3) Leg, arm, back, and neck braces and artificial legs, arms, and eyes, including...
Shpak, A A; Maliugin, B É; Fadeeva, T V
2012-01-01
Macula changes diagnosed with optical coherence tomography (OCT) within a year after cataract phacoemulsification (PE) with intraocular lens implantation with and without yellow filter are presented. 32 patients (36 eyes) with early stages of age macular degeneration (AMD) were included into the experimental group and 35 patients (36 eyes) served as controls. IOLs with yellow filter were implanted in 21 eyes, and in 15 cases IOLs without filter were used in each group. According to OCT data thickening of fovea and increasing of macula volume developed within 6 months after cataract PE. Implantation of yellow filter IOLs reduced the intensity of these changes after surgery in patients with AMD. The progression of early AMD into advanced stages within a year after PE was not observed.
Lessons learned: wrong intraocular lens.
Schein, Oliver D; Banta, James T; Chen, Teresa C; Pritzker, Scott; Schachat, Andrew P
2012-10-01
To report cases involving the placement of the wrong intraocular lens (IOL) at the time of cataract surgery where human error occurred. Retrospective small case series, convenience sample. Seven surgical cases. Institutional review of errors committed and subsequent improvements to clinical protocols. Lessons learned and changes in procedures adapted. The pathways to a wrong IOL are many but largely reflect some combination of poor surgical team communication, transcription error, lack of preoperative clarity in surgical planning or failure to match the patient, and IOL calculation sheet with 2 unique identifiers. Safety in surgery involving IOLs is enhanced both by strict procedures, such as an IOL-specific "time-out," and the fostering of a surgical team culture in which all members are encouraged to voice questions and concerns. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Laser-assisted marking for toric intraocular lens alignment.
Dick, H Burkhard; Schultz, Tim
2016-01-01
We describe a technique of 3-dimensional spectral-domain optical coherence tomography-controlled laser-assisted corneal marking for toric intraocular lens implantation. To facilitate accurate alignment, the technique creates 2 perpendicular intrastromal incisions (width 0.75 mm) using an image-guided femtosecond laser. This was performed in a case series comprising 10 eyes of 10 patients. No posterior corneal perforation or epithelial alterations occurred. The incisions were plainly visible under the operating microscope, and no optical phenomena were reported 6 weeks after surgery. Laser-assisted marking can be performed safely and has the potential to enable precise axis marking. Dr. Dick is a paid consultant to Abbott Medical Optics, Inc. Dr. Schultz has no financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Ferrer, Consuelo; Abu-Mustafa, Sabat K; Alió, Jorge L
2009-09-01
To report a pupil-supported, iris-clip intraocular lens (IOL) that was explanted more than 28 years after implantation. A pupil-supported, iris-clip, Sputnik-like IOL was implanted in the left eye of a 33-year-old man to correct aphakia after extracapsular cataract extraction due to trauma. Twenty-eight years after implantation, the patient was referred to our center with loss of vision. Clinical examination showed dislocation of the IOL, which was subsequently explanted. Scanning electron microscopic examination showed a transparent, polymethylmethacrylate (PMMA), pupil-supported, iris-clip IOL with melanosomes and cell deposits (foreign-body reaction) on its surface. This case demonstrates the inertness of PMMA material and reports that a foreign body reaction can be induced following IOL dislocation 28 years after implantation. Copyright 2009, SLACK Incorporated.
Neodymium:YAG laser cutting of intraocular lens haptics in vitro and in vivo.
Feder, J M; Rosenberg, M A; Farber, M D
1989-09-01
Various complications following intraocular lens (IOL) surgery result in explantation of the lenses. Haptic fibrosis may necessitate cutting the IOL haptics prior to removal. In this study we used the neodymium: YAG (Nd:YAG) laser to cut polypropylene and poly(methyl methacrylate) (PMMA) haptics in vitro and in rabbit eyes. In vitro we were able to cut 100% of both haptic types successfully (28 PMMA and 30 polypropylene haptics). In rabbit eyes we were able to cut 50% of the PMMA haptics and 43% of the polypropylene haptics. Poly(methyl methacrylate) haptics were easier to cut in vitro and in vivo than polypropylene haptics, requiring fewer shots for transection. Complications of Nd:YAG laser use frequently interfered with haptic transections in rabbit eyes. Haptic transection may be more easily accomplished in human eyes.
Parkash, Rohit Om; Mahajan, Shruti; Parkash, Tushya Om; Nayak, Vittal
2017-01-01
We describe a technique for performing safe phacoemulsification of a Morgagnian cataract using the intraocular lens (IOL) scaffold. An IOL scaffold has been used in cases in which posterior capsule rupture has occurred, leaving nonemulsified nuclear pieces. The scaffold provides a barrier that prevents the nuclear fragments from falling posteriorly into the vitreous cavity. Our technique uses the IOL as a scaffold to prevent the vulnerable posterior capsule from rupturing during nuclear emulsification in Morgagnian cataract. The technique prevents rupture of the floppy posterior capsule by providing a constant support to it. The scaffold provides stable inflation of the capsular bag and prevents inadvertent emulsification. Concurrently, it prevents dehiscence of weak zonular fibers by minimizing the stress on the zonular apparatus. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Thakur, Monica; Bhatia, Prashant; Chandrasekhar, Garudadri; Senthil, Sirisha
2016-02-26
Phacoemulsification with in-the-bag intraocular lens (IOL) implantation is the standard procedure for cataract surgery. Pigment dispersion and uveitis can result when an IOL is placed in the sulcus. We report a case of a 64-year-old woman, with pigmentary glaucoma, who developed recurrent uveitis following uneventful cataract surgery and an in-the-bag hydrophobic acrylic IOL implant. Recurrent uveitis did not subside despite use of topical steroids over 3 months. Dilated examination revealed capsulophimosis with anterior dislocation of the IOL haptic. The mechanical trauma to the iris due to the displaced haptic was implicated as the cause of recurrent uveitis, which completely resolved after capsular excision and IOL repositioning. This case illustrates a rare cause of recurrent uveitis due to IOL haptic dislocation following severe capsulophimosis. 2016 BMJ Publishing Group Ltd.
The effect of cataract surgery on sleep quality: a systematic review and Meta-analysis
Zheng, Ling; Wu, Xiao-Hang; Lin, Hao-Tian
2017-01-01
AIM To evaluate the effect of cataract surgery on sleep quality and to compare the difference between ultraviolet-blocking clear intraocular lens (UVB-IOL) and blue-filtering intraocular lens (BF-IOL) implantation. METHODS Electronic search was performed of PubMed, MEDLINE, Embase and the Cochrane Library up to January 2016. Studies were eligible when they evaluated the sleep quality before and after cataract surgery by Pittsburgh sleep quality index (PSQI). A random/fixed-effects Meta-analysis was used for the pooled estimate. Heterogeneity was assessed with the I2 test. RESULTS Six studies were selected from 5623 references. Cataract surgery significantly reduced the PSQI scores at postoperative 0-3mo [mean difference (MD) =-0.62, 95%CI: -1.14 to -0.11, P=0.02, I2=66%] and 3-12mo (MD=-0.32, 95%CI: -0.62 to -0.02, P=0.04, I2=0), respectively. Considering different intraocular lens (IOL) implantations, relative post-operative PSQI reduction was found for both UVB-IOL and BF-IOL, but a significant reduction was detected only for UVB-IOL. No significant difference was found with the effect of BF-IOL vs UVB-IOL on sleep quality. CONCLUSION This study found that cataract surgery significantly improved the PSQI score-derived subjective sleep quality irrespective of the IOL type implanted. These findings highlight a substantial benefit of cataract surgery on systemic health with photoreceptive restoration in addition to visual acuity improvements. PMID:29181319
Improved accuracy of intraocular lens power calculation with the Zeiss IOLMaster.
Olsen, Thomas
2007-02-01
This study aimed to demonstrate how the level of accuracy in intraocular lens (IOL) power calculation can be improved with optical biometry using partial optical coherence interferometry (PCI) (Zeiss IOLMaster) and current anterior chamber depth (ACD) prediction algorithms. Intraocular lens power in 461 consecutive cataract operations was calculated using both PCI and ultrasound and the accuracy of the results of each technique were compared. To illustrate the importance of ACD prediction per se, predictions were calculated using both a recently published 5-variable method and the Haigis 2-variable method and the results compared. All calculations were optimized in retrospect to account for systematic errors, including IOL constants and other off-set errors. The average absolute IOL prediction error (observed minus expected refraction) was 0.65 dioptres with ultrasound and 0.43 D with PCI using the 5-variable ACD prediction method (p < 0.00001). The number of predictions within +/- 0.5 D, +/- 1.0 D and +/- 2.0 D of the expected outcome was 62.5%, 92.4% and 99.9% with PCI, compared with 45.5%, 77.3% and 98.4% with ultrasound, respectively (p < 0.00001). The 2-variable ACD method resulted in an average error in PCI predictions of 0.46 D, which was significantly higher than the error in the 5-variable method (p < 0.001). The accuracy of IOL power calculation can be significantly improved using calibrated axial length readings obtained with PCI and modern IOL power calculation formulas incorporating the latest generation ACD prediction algorithms.
Complications of cataract surgery in eyes filled with silicone oil.
Kanclerz, Piotr; Grzybowski, Andrzej; Schwartz, Stephen G; Lipowski, Paweł
2018-03-01
The aim of the study was to evaluate complications of cataract surgery in eyes filled with silicone oil. This retrospective, noncomparative, consecutive case series analyzed medical files of patients with eyes filled with silicone oil undergoing cataract surgery. Phacoemulsification with posterior chamber intraocular lens implantation was conducted with or without concurrent silicone oil removal. In this study, 121 eyes of 120 patients were included. In 32 eyes (26.4%) with evident silicone oil microemulsification or silicone oil-associated open-angle glaucoma, silicone oil was removed prior to phacoemulsification through a pars plana incision and no cases of posterior capsular rupture occurred during the subsequent cataract surgery. In the remaining 89 eyes, phacoemulsification was performed with silicone oil in the vitreous cavity. In these eyes, the rate of posterior capsular rupture was 9/89 (10.1%) and the rate of silicone oil migration into the anterior chamber through an apparently intact posterior capsule was 5/89 (5.6%). In 94 eyes (77.7%), an intraocular lens was inserted into the capsular bag, in 3 eyes (2.5%) into the sulcus, and in 1 eye (0.8%) a transscleral suturing was performed. In this series, complications related to the silicone oil were not uncommon during cataract surgery. In the majority of patients without evident silicone oil microemulsification or silicone oil-associated open-angle glaucoma, cataract surgery and posterior chamber intraocular lens implantation were performed while leaving the silicone oil in place.
Surface Modification of Intraocular Lenses
Huang, Qi; Cheng, George Pak-Man; Chiu, Kin; Wang, Gui-Qin
2016-01-01
Objective: This paper aimed to review the current literature on the surface modification of intraocular lenses (IOLs). Data Sources: All articles about surface modification of IOLs published up to 2015 were identified through a literature search on both PubMed and ScienceDirect. Study Selection: The articles on the surface modification of IOLs were included, but those on design modification and surface coating were excluded. Results: Technology of surface modification included plasma, ion beam, layer-by-layer self-assembly, ultraviolet radiation, and ozone. The main molecules introduced into IOLs surface were poly (ethylene glycol), polyhedral oligomeric silsesquioxane, 2-methacryloyloxyethyl phosphorylcholine, TiO2, heparin, F-heparin, titanium, titanium nitride, vinyl pyrrolidone, and inhibitors of cytokines. The surface modification either resulted in a more hydrophobic lens, a more hydrophilic lens, or a lens with a hydrophilic anterior and hydrophobic posterior surface. Advances in research regarding surface modification of IOLs had led to a better biocompatibility in both in vitro and animal experiments. Conclusion: The surface modification is an efficient, convenient, economic and promising method to improve the biocompatibility of IOLs. PMID:26830993
NASA Astrophysics Data System (ADS)
Chen, Yi-Chun; Jiang, Chong-Jhih; Yang, Tsung-Hsun; Sun, Ching-Cherng
2012-07-01
A biometry-based human eye model was developed by using the empirical anatomic and optical data of ocular parameters. The gradient refractive index of the crystalline lens was modeled by concentric conicoid isoindical surfaces and was adaptive to accommodation and age. The chromatic dispersion of ocular media was described by Cauchy equations. The intraocular scattering model was composed of volumetric Mie scattering in the cornea and the crystalline lens, and a diffusive-surface model at the retina fundus. The retina was regarded as a Lambertian surface and was assigned its corresponding reflectance at each wavelength. The optical performance of the eye model was evaluated in CodeV and ASAP and presented by the modulation transfer functions at single and multiple wavelengths. The chromatic optical powers obtained from this model resembled that of the average physiological eyes. The scattering property was assessed by means of glare veiling luminance and compared with the CIE general disability glare equation. By replacing the transparent lens with a cataractous lens, the disability glare curve of cataracts was generated to compare with the normal disability glare curve. This model has high potential for investigating visual performance in ordinary lighting and display conditions and under the influence of glare sources.
[Fabrication and Performance Study of Polydimethylsiloxane Intraocular Lens].
Du, Qiuyue; Yu, Yueqing
2016-10-01
To simplify the production process of intraocular lens(IOL)and to solve the problem of lacking adjustable ability,we proposed a novel soft IOL with large-scale adjustable ability and rigid haptics based on heat-assisted method,and gravity-assisted method.Polydimethylsiloxane(PDMS)and rigid material--polymethyl methacrylate(PMMA)were used as the materials for fabricating optical lens(PDMS)and haptics(PDMS and PMMA)through changing the weight ratio of the solution.A lens-smartphone microscopy system was established to replace the traditional digital microscopy to measure the tiny displacements and shape changes.The PDMS lens has excellent optical property through an experiment in which the maximum optical power was around 273.2D.Experimental results indicated that the maximum optical power of PMMA IOL was 129.3D,and that in PDMS IOL,however,was only 56.0D.Thus,the rigid PMMA-IOL has a larger adjustable range.The production process of PDMS was mold-free,rapid,real-time,and highly repeatable and there was no need for a rigorous experimental environment either.This creative processing technology reduced the manufacturing steps from which an optical lens with high transmittance and high resolution,as well as hatics with accurate dimensions,were obtained.The rigidity of haptics affected more intensely than other factors did for improving the pre-displacement and changing the appearance of PDMS lens.Even though the rigidity of PMMA haptics is large enough for accommodating,there are many drawbacks during manufacturing.It is unavailable to rapid fabricate IOL using PMMA.Thus,further work will be required to alter the weight ratio of PDMS material,increase the rigidity,and enhance the adjustable ability of PDMS IOL.
Comparison of glare in YAG-damaged intraocular lenses: injection-molded versus lathe-cut.
Bath, P E; Dang, Y; Martin, W H
1986-11-01
A comparative analysis of YAG laser intraocular lens (IOL) damage was undertaken on injection-molded and lathe-cut IOLs. Damage sites were evaluated with polarized light. A consistent positive polarization was observed in the damage sites of lathe-cut IOLs. A consistent negative polarization was observed in the damage sites of injection-molded IOLs. The presence of positive polarization in IOL damage sites may be correlated with increased potential for glare. Results and clinical implications are discussed.
Intraocular and crystalline lens protection from ultraviolet damage.
Sliney, David H
2011-07-01
Although the risks of excess solar ultraviolet (UV) exposure of the skin are well recognized, the need for eye protection is frequently overlooked, or when sunglasses are also recommended, specific guidance is wrong or is not explained. Guidance from the World Health Organization at its InterSun webpage advises people to wear "wrap-around" sunglasses under many conditions. The objective of this study was to examine the need for UV filtration in prescription lenses, contact lenses, and sunglasses. The geometry of UV exposure of both eyes, solar position, ground reflection, pupil size, and lid opening were studied. Because an accurate determination of cumulative ocular exposure is difficult, the cornea itself can serve as a biologic dosimeter, because photokeratitis is not experienced on a daily basis but does under certain ground-surface and sunlight conditions. From a knowledge of the UV-threshold dose required to produce photokeratitis, we have an upper level of routine ocular exposure to ambient UV. From ambient UV measurements and observed photokeratitis, the upper limits of UV exposure of the crystalline lens or an intraocular lens implant are estimated. The risk of excess UV exposure of the germinative cells of the lens is greatest from the side. Sunglasses can actually increase UV exposure of the germinative region of the crystalline lens and the corneal limbus by disabling the eyes' natural protective mechanisms of lid closure and pupil constriction! The level of UV-A risk is difficult to define. Proper UV-absorbing contact lenses offer the best mode for filtering needless exposure of UV radiation of the lens and limbus.
Accommodation-Amplitudes following an Accommodative Lens Refilling Procedure — an in vivo Update
Nishi, Okihiro; Nishi, Yutaro; Chang, S.; Nishi, Kayo
2014-01-01
Purpose To investigate whether a newly developed lens refilling procedure can provide some accommodation in monkey eyes and to evaluate the difference in accommodation with different degrees of capsular bag refilling. Setting Jinshikai Medical Foundation, Nishi Eye Hospital, Osaka, Japan. Design Experimental monkey study. Methods Following a central 3–4 mm continuous curvilinear capsulorhexis, phacoemulsification was performed in the usual manner. A novel accommodative membrane intraocular lens for sealing capsular opening was implanted into the capsular bag. Silicone polymers were injected beneath the intraocular lens into the capsular bag through the delivery hole. In three study groups, each with six monkey eyes, the lens capsule was refilled with 0.08 ml corresponding to 65% bag volume, 0.1 ml corresponding to 80% bag volume, and 0.125 ml of silicone polymers corresponding to 100% bag volume, respectively. To calculate the accommodation-amplitudes achieved, automated refractometry was performed before and 1 hour after the topical 4% pilocarpine application before and four weeks after surgery. Results The refilling technique was successful in all monkeys without polymer leakage. Accommodation-amplitudes attained were 2.56 ± 0.74 dioptries (D), 2.42 ± 1.00D, and 2.71 ± 0.63D, respectively, 4 weeks after surgery in the three study groups. Conclusions Using the technique, some accommodation could be obtained in the young monkey eyes. Leakage of the injectable silicone polymer and anterior capsular opacification at least in the visual axis could be avoided. The results suggest that this lens refilling procedure warrants further studies for a possible clinical application. PMID:24461501
McLeod, Stephen D.
2006-01-01
Purpose To design and develop an accommodating intraocular lens (IOL) for endocapsular fixation with extended accommodative range that can be adapted to current standard extracapsular phacoemulsification technique. Methods Ray tracing analysis and lens design; finite element modeling of biomechanical properties; cadaver eye implantation; initial clinical evaluation. Results Ray tracing analysis indicated that a dual-optic design with a high plus-power front optic coupled to an optically compensatory minus posterior optic produced greater change in conjugation power of the eye compared to that produced by axial movement of a single-optic IOL, and that magnification effects were unlikely to account for improved near vision. Finite element modeling indicated that the two optics can be linked by spring-loaded haptics that allow anterior and posterior axial displacement of the front optic in response to changes in ciliary body tone and capsular tension. A dual-optic single-piece foldable silicone lens was constructed based on these principles. Subsequent initial clinical evaluation in 24 human eyes after phacoemulsification for cataract indicated mean 3.22 diopters of accommodation (range, 1 to 5 D) based on defocus curve measurement. Accommodative amplitude evaluation at 1- and 6-month follow-up in all eyes indicated that the accommodative range was maintained and that the lens was well tolerated. Conclusions A dual-optic design increases the accommodative effect of axial optic displacement, with minimal magnification effect. Initial clinical trials suggest that IOLs designed on this principle might provide true pseudophakic accommodation following cataract extraction and lens implantation. PMID:17471355
Management of iatrogenic crystalline lens injury occurred during intravitreal injection.
Erdogan, Gurkan; Gunay, Betul Onal; Unlu, Cihan; Gunay, Murat; Ergin, Ahmet
2016-08-01
To evaluate the approach to management of iatrogenic crystalline lens injury occurred during intravitreal injection (IVI). The patients who were managed operatively or followed-up without intervention after the iatrogenic lens injury due to IVI were included in the study. Capsular breaks remained either quiescent or resulted in cataract formation in the patients with inadvertent crystalline lens capsule damage. Phacoemulsification surgery was performed in patients with cataract formation with lower fluidic settings. A total of 9 cases included in the study. Seven cases underwent phacoemulsification with intraocular lens implantation. Two cases remained as quiescent lens injury during the follow-up. In 2 cases, dislocation of lens fragments occurred during phacoemulsification where pars plana vitrectomy was performed at the same session. After iatrogenic crystalline lens injury, capsular damage could remain quiescent or progress to cataract formation. Although phacoemulsification surgery can be performed with appropriate parameters, lens fragment dislocation can be observed in cases with traumatic lens damage secondary to IVI.
The impact of intraocular pressure on elastic wave velocity estimates in the crystalline lens.
Park, Suhyun; Yoon, Heechul; Larin, Kirill V; Emelianov, Stanislav Y; Aglyamov, Salavat R
2016-12-20
Intraocular pressure (IOP) is believed to influence the mechanical properties of ocular tissues including cornea and sclera. The elastic properties of the crystalline lens have been mainly investigated with regard to presbyopia, the age-related loss of accommodation power of the eye. However, the relationship between the elastic properties of the lens and IOP remains to be established. The objective of this study is to measure the elastic wave velocity, which represents the mechanical properties of tissue, in the crystalline lens ex vivo in response to changes in IOP. The elastic wave velocities in the cornea and lens from seven enucleated bovine globe samples were estimated using ultrasound shear wave elasticity imaging. To generate and then image the elastic wave propagation, an ultrasound imaging system was used to transmit a 600 µs pushing pulse at 4.5 MHz center frequency and to acquire ultrasound tracking frames at 6 kHz frame rate. The pushing beams were separately applied to the cornea and lens. IOP in the eyeballs was varied from 5 to 50 mmHg. The results indicate that while the elastic wave velocity in the cornea increased from 0.96 ± 0.30 m s -1 to 6.27 ± 0.75 m s -1 as IOP was elevated from 5 to 50 mmHg, there were insignificant changes in the elastic wave velocity in the crystalline lens with the minimum and the maximum speeds of 1.44 ± 0.27 m s -1 and 2.03 ± 0.46 m s -1 , respectively. This study shows that ultrasound shear wave elasticity imaging can be used to assess the biomechanical properties of the crystalline lens noninvasively. Also, it was observed that the dependency of the crystalline lens stiffness on the IOP was significantly lower in comparison with that of cornea.
Current Perspectives of Prophylaxis and Management of Acute Infective Endophthalmitis.
Tranos, Paris; Dervenis, Nikolaos; Vakalis, Athanasios N; Asteriadis, Solon; Stavrakas, Panagiotis; Konstas, Anastasios G P
2016-05-01
Endophthalmitis is an intraocular inflammatory condition which may or may not be caused by infective agents. Noninfectious (sterile) endophthalmitis may be attributable to various causes including postoperative retained soft lens matter or toxicity following introduction of other agents into the eye. Infectious endophthalmitis is further subdivided into endogenous and exogenous. In endogenous endophthalmitis there is hematogenous spread of organisms from a distant source of infection whereas in exogenous endophthalmitis direct microbial inoculation may occur usually following ocular surgery or penetrating eye injury with or without intraocular foreign bodies. Acute infective endophthalmitis is usually exogenous induced by inoculation of pathogens following ocular surgery, open-globe injury and intravitreal injections. More infrequently the infective source is internal and septicemia spreads to the eye resulting in endogenous endophthalmitis. Several risk factors have been implicated including immunosuppression, ocular surface abnormalities, poor surgical wound construction, complicated cataract surgery with vitreous loss and certain types of intraocular lens. Comprehensive guidelines and recommendations on prophylaxis and monitoring of surgical cases have been proposed to minimize the risk of acute endophthalmitis. Early diagnosis and prompt management of infective endophthalmitis employing appropriately selected intravitreal antibiotics are essential to optimize visual outcome.
Extended depth of focus intraocular lens: Chromatic performance
Millán, Maria S.; Vega, Fidel
2017-01-01
We describe a first-and-second-diffractive-order intraocular lens ((1st,2nd)DIOL) within the class of hybrid refractive-diffractive designs for intraocular lenses (IOLs) and analyse its properties of focus extension and compensation of longitudinal chromatic aberration (LCA), particularly for lenses with low addition. Power, energy efficiency and their wavelength dependence are extended from monofocal IOL and conventional bifocal zeroth-and-first-diffractive-order IOL ((0th,1st)DIOL) to (1st,2nd)DIOL of low addition. Compensation of LCA is experimentally assessed in optical bench through the through-focus energy efficiency of three Tecnis IOLs with red, green and blue illuminations: ZA9003 (monofocal), ZKB00 (bifocal (0th,1st)DIOL with + 2.75 D add) and Symfony ZXR00. We prove Tecnis Symfony ZXR00 IOL can be considered an example of (1st,2nd)DIOL design of low addition, with LCA compensation in both the distance and intermediate foci, whereas the bifocal (0th,1st)DIOL does not compensate in the distance focus. However, the energy efficiency of (1st,2nd)DIOL for wavelengths other than the design wavelength is markedly more asymmetric. PMID:28966865
Bajgai, Priya; Tigari, Basavraj; Singh, Ramandeep
2017-10-04
To compare the outcome of 23-gauge as compared with 25-gauge transconjunctival sutureless vitrectomy (TSV) in the management of dislocated intraocular lenses (IOLs). Retrospective, non-consecutive, comparative, interventional case series. Patients with dislocated intraocular lens who underwent sutureless PPV using either 23-gauge or 25-gauge instruments. The patients who presented with a dislocated IOL, underwent TSV with repositioning of the intraocular lens, either in the sulcus or scleral-fixated sutured/glued. Of the total 61 eyes, 33 (54.09%) underwent 23-gauge TSV and 28 (45.90%) underwent 25-gauge TSV. The mean logMAR BCVA at baseline and 6 months after surgery was 0.8 and 0.46 in the 23-gauge group, and 0.82 and 0.47 in the 25-gauge group. There was no significant difference in logMAR BCVA values between the two groups at any time point of time during the follow-up. The mean postoperative IOP on postoperative day 1 was 14.76 ± 5.4 in 23-gauge group and 17.57 ± 7.9 in the 25-gauge group (p = 0.10). Retinal break was noticed intraoperatively in two cases in 23-gauge group and in three cases in 25-gauge group (p = 0.509). Postoperative complications included IOL decentration in one case of 23-gauge vitrectomy and two cases in 25-gauge group (p = 0.5), cystoid macular edema in four patients in 23-gauge group and six cases of 25-gauge group (p = 0.3) and retinal detachment in one case in each group (p = 0.9). 25-gauge appears to be as safe and as effective as 23-gauge TSV in the management of dislocated intraocular lenses.
Intraocular camera for retinal prostheses: Refractive and diffractive lens systems
NASA Astrophysics Data System (ADS)
Hauer, Michelle Christine
The focus of this thesis is on the design and analysis of refractive, diffractive, and hybrid refractive/diffractive lens systems for a miniaturized camera that can be surgically implanted in the crystalline lens sac and is designed to work in conjunction with current and future generation retinal prostheses. The development of such an intraocular camera (IOC) would eliminate the need for an external head-mounted or eyeglass-mounted camera. Placing the camera inside the eye would allow subjects to use their natural eye movements for foveation (attention) instead of more cumbersome head tracking, would notably aid in personal navigation and mobility, and would also be significantly more psychologically appealing from the standpoint of personal appearances. The capability for accommodation with no moving parts or feedback control is incorporated by employing camera designs that exhibit nearly infinite depth of field. Such an ultracompact optical imaging system requires a unique combination of refractive and diffractive optical elements and relaxed system constraints derived from human psychophysics. This configuration necessitates an extremely compact, short focal-length lens system with an f-number close to unity. Initially, these constraints appear highly aggressive from an optical design perspective. However, after careful analysis of the unique imaging requirements of a camera intended to work in conjunction with the relatively low pixellation levels of a retinal microstimulator array, it becomes clear that such a design is not only feasible, but could possibly be implemented with a single lens system.
IOL Implants: Lens Replacement and Cataract Surgery (Intraocular Lenses)
... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...
Clinical and biometric determinants of actual lens position after cataract surgery.
Plat, Julien; Hoa, Didier; Mura, Frederic; Busetto, Timothe; Schneider, Christelle; Payerols, Arnaud; Villain, Max; Daien, Vincent
2017-02-01
To evaluate the preoperative clinical and biometric determinants associated with the actual lens position after cataract surgery. Department of Ophthalmology, University Hospital of Montpellier, France. Prospective longitudinal cohort study. The data collected included clinical factors (age, sex, history of vitrectomy) and biometry factors (axial length [AL], anterior chamber depth [ACD], lens thickness, white-to-white [WTW] distance) that might affect actual lens position. Each patient had optical low-coherence reflectometry biometry (Lenstar) preoperatively and 1 month postoperatively. The actual lens position was measured as the postoperative position of the center of the intraocular lens (IOL). Patients were stratified into 3 groups by type of IOL: Acrysof SN60WF or SN6AT (Group 1), Tecnis ZCB00 or ZCT (Group 2), and Asphina 409 MV (Group 3). The study comprised 168 eyes (mean age 73.3 years ± 9.8 [SD]). The mean actual lens position was 4.88 ± 0.29 mm, 5.01 ± 0.29 mm, and 5.05 ± 0.32 mm in Group 1 (n = 67 eyes), Group 2 (n = 52 eyes), and Group 3 (n = 49 eyes), respectively. In the overall population, AL, ACD, anterior segment depth, and WTW distance were correlated with actual lens position (r = 0.48, P < .0001; r = 0.64, P < .001; r = 0.58, P < .0001; r = 0.39, P < .001, respectively). The AL, ACD, anterior segment depth, and WTW distance correlated with actual lens position after cataract surgery. The integration of these data in IOL formulas could help improve refractive outcomes after the surgery. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Rotation stability of a toric intraocular lens with a second capsular tension ring.
Sagiv, Oded; Sachs, Dan
2015-05-01
An Acrysof toric intraocular lens (IOL) and a capsular tension ring (CTR) were implanted in the highly myopic eye of a 74-year-old white man during cataract surgery. On the first postoperative day, the IOL was found 90 degrees from the required position, with a consequent high amount of astigmatism. A second procedure was performed and because it was not possible to secure the toric IOL in the correct position, an additional in-the-bag CTR was inserted, with an immediate optimal outcome. The IOL remained stable up to the final follow-up examination. Co-implantation of a toric IOL and a single CTR has been reported. In our case, 2 CTRs were required to fixate the toric IOL in the correct position. This procedure is simple and safe and should be considered in cases of postoperatively misaligned toric IOLs. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Post-keratoplasty astigmatism management by relaxing incisions: a systematic review.
Ho Wang Yin, Gaëlle; Hoffart, Louis
2017-01-01
Postoperative visual acuity can be limited by post-keratoplasty astigmatism, even with a clear corneal graft. Astigmatism management can be performed by selective suture removal, adjustment of sutures, optical correction, photorefractive procedures, wedge resection, intra-ocular lens implantation, intracorneal ring segments, relaxing incisions with or without compression sutures and repeated keratoplasty. Relaxing incisions can be made in the graft, graft-host interface or host cornea. Despite the unpredictability of the method because the flat and steep meridians are usually not orthogonal after penetrating keratoplasty, with asymmetric power distribution, all the studies showed an overall reduction of refractive, keratometric or topographic astigmatism, ranging from 30% to 72% with manual or femtosecond-assisted techniques. Most patients with astigmatism higher than 6 diopters had residual cylinder less than or equal to 3 diopters, which can be treated by laser excimer ablation or secondary intraocular lens implantation.
Luck, Jonathan
2010-07-01
I report a case of pellucid marginal degeneration (PMD) with cataract that was successfully treated with implantation of an ultra-high-power customized bitoric AT.Comfort 646TLC intraocular lens (IOL). The preoperative uncorrected distance visual acuity (UDVA) was 6/120 and the corrected distance visual acuity (CDVA), 6/24 with 10.9 diopters (D) of keratometric astigmatism on Scheimpflug imaging. After implantation of an IOL with -0.5 +16.0 x 170, the UDVA was 6/9 with a manifest refraction of +0.25 +1.25 x 150 and the CDVA, 6/6(-1). No surgical complications or postoperative problems occurred, and the patient was very satisfied with the outcome. A longer follow-up is required to confirm this favorable clinical result. The author has no financial or proprietary interest in any material or method mentioned. Copyright 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Can, Ertuğrul; Koçak, Nurullah; Yücel, Özlem Eşki; Gül, Adem; Öztürk, Hilal Eser; Sayın, Osman
2016-01-01
Aim of Study: To describe a simplified ab-interno cow-hitch suture fixation technique for repositioning decentered posterior chamber intraocular lens (PC IOL). Materials and Methods: Two cases are presented with the surgical correction of decentered and subluxated IOL. Ab-interno scleral suture fixation technique with hitch-cow knot in the eye was performed with a ciliary sulcus guide instrument and 1 year follow-up was completed. Results: Both of the patients had well centered lenses postoperatively. Corrected distant and near visual acuities of the patients were improved. There was no significant postoperative complication. In the follow-up period of 1 year, no evidence of suture erosion was found. Conclusions: Ab-interno scleral suture loop fixation with hitch-cow knot in the eye was effective in repositioning decentered or subluxated PC IOLs with excellent postoperative centered lenses and visual outcomes. PMID:27050346
Lenticular abnormalities in children.
Khokhar, Sudarshan; Agarwal, Tushar; Kumar, Gaurav; Kushmesh, Rakhi; Tejwani, Lalit Kumar
2012-01-01
To study the lenticular problems in children presenting at an apex institute. Retrospective analysis of records (< 14 years) of new lens clinic cases was done. Of 1,047 children, 687 were males. Mean age at presentation was 6.35 ± 4.13 years. Developmental cataract was seen in 45.6% and posttraumatic cataract in 29.7% of patients. Other abnormalities were cataract with retinal detachment, persistent hyperplastic primary vitreous, subluxated lens, micro/spherophakia, cataract secondary to uveitis, intraocular lens complications, cataract with choroidal coloboma, and visual axis opacification. Developmental and posttraumatic cataracts were the most common abnormalities. Delayed presentation is of concern. Copyright 2012, SLACK Incorporated.
Progressive lenticular astigmatism in the clear lens.
Tatham, Andrew; Prydal, Jeremy
2008-03-01
We describe a case of progressive lenticular astigmatism in a 53-year-old man with a clear lens. The patient acquired 5 diopters of lenticular astigmatism in his right eye over an 18-month period. The visual acuity was reduced to 6/60. Following phacoemulsification and intraocular lens implantation, the uncorrected visual acuity was 6/5. Progressive astigmatism is usually corneal in origin and in an otherwise healthy eye, significant lenticular astigmatism is rare. When lenticular astigmatism occurs, it is usually associated with a cortical cataract; however, astigmatism may precede the development of a clinically visible cataract.
Javanbakht, Mehdi; Azuara-Blanco, Augusto; Burr, Jennifer M; Ramsay, Craig; Cooper, David; Cochran, Claire; Norrie, John; Scotland, Graham
2017-01-01
Objective To investigate the cost-effectiveness of early lens extraction with intraocular lens implantation for the treatment of primary angle closure glaucoma (PACG) compared to standard care. Design Cost-effectiveness analysis alongside a multicentre pragmatic two-arm randomised controlled trial. Patients were followed-up for 36 months, and data on health service usage and health state utility were collected and analysed within the trial time horizon. A Markov model was developed to extrapolate the results over a 5-year and 10-year time horizon. Setting 22 hospital eye services in the UK. Population Males and females aged 50 years or over with newly diagnosed PACG or primary angle closure (PAC). Interventions Lens extraction compared to standard care (ie, laser iridotomy followed by medical therapy and glaucoma surgery). Outcome measures Costs of primary and secondary healthcare usage (UK NHS perspective), quality-adjusted life years (QALYs) and the incremental cost-effectiveness ratio (ICER) for lens extraction versus standard care. Results The mean age of participants was 67.5 (8.42), 57.5% were women, 44.6% had both eyes eligible, 1.4% were of Asian ethnicity and 35.4% had PAC. The mean health service costs were higher in patients randomised to lens extraction: £2467 vs £1486. The mean adjusted QALYs were also higher with early lens extraction: 2.602 vs 2.533. The ICER for lens extraction versus standard care was £14 284 per QALY gained at three years. Modelling suggests that the ICER may drop to £7090 per QALY gained by 5 years and that lens extraction may be cost saving by 10 years. Our results are generally robust to changes in the key input parameters and assumptions. Conclusions We find that lens extraction has a 67–89% chance of being cost-effective at 3 years and that it may be cost saving by 10 years. Trial registration number ISRCTN44464607; Results. PMID:28087548
Optimized constants for an ultraviolet light-adjustable intraocular lens.
Conrad-Hengerer, Ina; Dick, H Burkhard; Hütz, Werner W; Haigis, Wolfgang; Hengerer, Fritz H
2011-12-01
To determine the accuracy of intraocular lens (IOL) power calculations and to suggest adjusted constants for implantation of ultraviolet light-adjustable IOLs. Center for Vision Science, Ruhr University Eye Clinic, Bochum, Germany. Cohort study. Eyes with a visually significant cataract that had phacoemulsification with implantation of a light-adjustable IOL were evaluated. IOLMaster measurements were performed before phacoemulsification and IOL implantation and 4 weeks after surgery before the first adjustment of the IOL. The difference in the expected refraction and estimation error was studied. The study evaluated 125 eyes. Using the surgical constants provided by the manufacturer of the light-adjustable IOL, the SRK/T formula gave a more hyperopic refraction than the Hoffer Q and Holladay 1 formulas. The mean error of prediction was 0.93 diopter (D) ± 0.69 (SD), 0.91 ± 0.63 D, and 0.86 ± 0.65 D, respectively. The corresponding mean absolute error of prediction was 0.98 ± 0.61 D, 0.93 ± 0.61 D, and 0.90 ± 0.59 D, respectively. With optimized constants for the formulas, the mean error of prediction was 0.00 ± 0.63 D for Hoffer Q, 0.00 ± 0.64 D for Holladay 1, and 0.00 ± 0.66 D for SRK/T. The expected refraction after phacoemulsification and implantation of a light-adjustable IOL toward the hyperopic side of the desired refraction could be considered when using the optimized constants for all formulas. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Ray-tracing analysis of intraocular lens power in situ.
Olsen, Thomas; Funding, Mikkel
2012-04-01
To describe a method for back-solving the power of an intraocular lens (IOL) in situ based on laser biometry and ray-tracing analysis of the pseudophakic eye. University Eye Clinic, Aarhus Hospital, Aarhus, Denmark. Evaluation of diagnostic test or technology. This study comprised pseudophakic eyes with an IOL power ranging from -2.00 to +36.00 diopters (D). Preoperatively, the corneal radius was measured with conventional autokeratometry and the axial length (AL) with optical biometry. After surgery, the position of the IOL was recorded using laser interferometry. Based on the postoperative refraction and the biometric measurements, a ray-tracing analysis was performed back-solving for the power of the IOL in situ. The analysis was performed assuming pupil diameters from 0.0 to 8.0 mm with and without correction for the Stiles-Crawford effect. The study evaluated 767 pseudophakic eyes (583 patients). Assuming a 3.0 mm pupil, the mean prediction error between the labeled and the calculated IOL power (± 1 standard deviation [SD]) was -0.26 D ± 0.65 (SD) (range -2.4 to +1.8 D). The prediction error showed no bias with IOL power or with AL. The calculated IOL power depended on the assumed pupil size and the Stiles-Crawford effect. However, the latter had a modulatory effect on the prediction error for large pupil diameters (>5.0 mm) only. The optics of the pseudophakic eye can be accurately described using exact ray tracing and modern biometric techniques. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Evaluation of a new soft tipped injector for the implantation of foldable intraocular lenses.
Kleinmann, Guy; Apple, David J
2007-08-01
To evaluate the R-INJ-04 soft-tipped injector, a new injector with an integral round nozzle manufactured by Rayner Intraocular Lenses, England. 16 Rayner C-flex intraocular lenses (IOLs; Rayner Intraocular lenses, England) ranging between +10 and +30 D (2 for each power) were tested. An ophthalmic viscoelastic device (Healon, AMO, Santa Ana, California, USA) was applied to the injectors. The IOLs were loaded according to the company injector's instructions for use and were injected into a Petri dish. After the injection, all the IOLs and nozzles were evaluated by gross (macroscopic) and microscopic analyses and photographed under a light microscope. One lens of each power and the cartridge used for the implantation were then sent for further analysis by scanning electron microscopy (SEM). The rest of the IOLs were tested for power and modulation transfer function (MTF). All the injections were successful. No damage to the IOLs or to the injectors was found by gross examination, light microscopy and SEM. No deposits were found on the IOL optical surfaces or haptics. Power and MTF analysis showed a close match with the original measurements. Our results suggest that the R-INJ-04 soft-tipped injector is safe for the implantation of the C-flex IOL with power range from 10 to 30 D. No structural damage to the IOLs or to the injectors was found, and the lens power and light transmission properties were not damaged in any way by the injection process.
Mainster, Martin A; Turner, Patricia L
2010-04-01
Ultraviolet-B (UV-B) radiation can cause phototoxic macular injuries in young people who have been sunbathing but not sungazing and in welders. Welders have a reportedly increased risk of uveal melanoma. We analyze phakic and pseudophakic risks for solar and welding arc UV-B exposure. Optical radiation measurement, analysis, and perspective. Spectral transmittances were measured for UV-transmitting, UV-blocking, and blue-blocking intraocular lenses (IOLs). The photoprotective performances of crystalline and intraocular lenses were analyzed using relevant epidemiologic and laboratory data and action spectra for acute retinal phototoxicity and melanoma photocarcinogenesis. Crystalline lens UV-B retinal protection is deficient in children and young adults, increasing their potential susceptibility to acute retinal phototoxicity and hypothetical photomelanomagenesis. UV-B radiation has sufficient energy/photon to induce primary melanomagenic DNA lesions, unlike blue light or UV-A radiation. UV-blocking and blue-blocking IOLs have negligible UV-B transmittance. UV-transmitting IOL transmittance of UV-B radiation is equivalent to that of a 15-year-old crystalline lens. If optical radiation exposure is responsible for welders' increased risk of uveal melanoma, then UV-B radiation is the most probable causative agent and spectacle wear is a potential confounding factor in epidemiologic studies of ocular melanoma. Welders under 30 years of age are at greater risk for welding maculopathy than older welders. Children, adults under 30 years of age, and pseudophakic individuals with UV-transmitting IOLs should wear sunglasses in bright environments because of the UV-B window in their crystalline lenses or IOLs. Copyright 2010 Elsevier Inc. All rights reserved.
Farooqui, Javed Hussain; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo
2015-01-01
Visual performance following toric intraocular lens implantation for cataract with moderate and severe astigmatism. Cataract services, Shroff Eye Centre, New Delhi, India. Case series. This prospective study included 64 eyes of 40 patients with more than 1.50 dioptre (D) of pre-existing corneal astigmatism undergoing phacoemulsification with implantation of the AcrySof® toric IntraOcular Lens (IOL). The unaided visual acuity (UCVA), best corrected visual acuity (BCVA), residual refractive sphere and refractive cylinders were evaluated. Toric IOL axis and alignment error was measured by slit lamp method and Adobe Photoshop (version 7) method. Patient satisfaction was evaluated using a satisfaction questionnaire at 3 months. The mean residual refractive astigmatism was 0.57 D at the final follow-up of 3 months. Mean alignment error was 3.44 degrees (SD = 2.60) by slit lamp method and 3.88 degrees (SD = 2.86) by Photoshop method. Forty-six (71.9%) eyes showed misalignment of 5 degrees or less, and 60 (93.8%) eyes showed misalignment of 10 degrees or less. The mean log MAR UCVA at 1st post-op day was 0.172 (SD = 0.02), on 7th post-op day was 0.138 (SD = 0.11), and on 30th post-op day was 0.081 (SD = 0.11). The mean log MAR BCVA at three months was -0.04 (SD = 0.76). We believe that implantation of AcrySof® toric IOL is an effective, safe and predictable method to correct high amounts of corneal astigmatism during cataract surgery.
Yaguchi, Shigeo; Nishihara, Hitoshi; Kambhiranond, Waraporn; Stanley, Daniel; Apple, David J
2008-01-01
To investigate the cause of light scatter measured on the surface of AcrySof intraocular lenses (Alcon Laboratories, Inc., Fort Worth, TX) retrieved from pseudophakic postmortem human eyes. Ten intraocular lenses (Alcon AcrySofModel MA60BM) were retrieved postmortem and analyzed for light scatter before and after removal of surface-bound biofilms. Six of the 10 lenses exhibited light scatter that was clearly above baseline levels. In these 6 lenses, both peak and average pixel density were reduced by approximately 80% after surface cleaning. The current study demonstrates that a coating deposited in vivo on the lens surface is responsible for the light scatter observed when incident light is applied.
Papaconstantinou, Dimitris; Kalantzis, George; Brouzas, Dimitris; Kontaxakis, Anastasios; Koutsandrea, Chryssanthi; Diagourtas, Andreas; Georgalas, Ilias
2016-01-01
The aim of this study was to compare the results of phacoemulsification through a small pupil using minimal iris manipulation versus phacoemulsification through a well-dilated pupil. This prospective randomized control (comparative) study comprised 78 patients (group I) with a maximally dilated pupil size of ≤4.00 mm and 45 patients (group II) with dilated pupil size of ≥7.00 mm. In group I patients, only viscodilation and minimal push-and-pull iris stretching with two collar-button iris-retractor hooks were utilized without iris manipulation. Phacoemulsification was performed by two senior surgeons and the technique used consisted of either stop and chop or quick chop, infusion/aspiration of lens cortex, capsular bag refill with ocular viscoelastic devices, and implantation of an acrylic foldable intraocular lens. Patients were examined on the first day and 1 month postoperatively. Forty-six eyes of group I patients had pseudoexfoliation syndrome, eleven eyes had previous glaucoma surgery, 14 eyes had angle-closure or open-angle glaucoma, and seven eyes had posterior synechiae with iritis. In group I patients, the mean pupil size measured under an operating microscope was 3.2 mm preoperatively, 4.3 mm after viscoelastic and mechanical pupil dilation, and 4.1 mm at the end of a surgical procedure. Rupture of the zonular fibers occurred in six patients of group I and the intraocular lens was implanted in the sulcus. Small iris-sphincter rupture and small hemorrhages occurred in four eyes during pupillary manipulation, but they were not evident at the end of the surgery. In group II patients, no intraoperative complications occurred. Signs of significant corneal edema and iritis were observed more frequently in group I eyes (26 eyes and 20 eyes, respectively) on the first postoperative day in comparison with group II eyes (ten eyes and six eyes, respectively). Intraocular pressure was <20 mmHg in all eyes of both groups. One month postoperatively, the pupil was round and reactive to light, the anterior chamber was quiet, and the cornea was clear in all eyes. The best-corrected visual acuity on Snellen chart was 20/40 (Monoyer's scale) or better in both groups. Phacoemulsification through a small pupil using minimal iris manipulation can be safe and exhibits the same results as those obtained with phacoemulsification through normal pupils.
Design of a Test Bench for Intraocular Lens Optical Characterization
NASA Astrophysics Data System (ADS)
Alba-Bueno, Francisco; Vega, Fidel; Millán, María S.
2011-01-01
The crystalline lens is the responsible for focusing at different distances (accommodation) in the human eye. This organ grows throughout life increasing in size and rigidity. Moreover, due this growth it loses transparency through life, and becomes gradually opacified causing what is known as cataracts. Cataract is the most common cause of visual loss in the world. At present, this visual loss is recoverable by surgery in which the opacified lens is destroyed (phacoemulsification) and replaced by the implantation of an intraocular lens (IOL). If the IOL implanted is mono-focal the patient loses its natural capacity of accommodation, and as a consequence they would depend on an external optic correction to focus at different distances. In order to avoid this dependency, multifocal IOLs designs have been developed. The multi-focality can be achieved by using either, a refractive surface with different radii of curvature (refractive IOLs) or incorporating a diffractive surface (diffractive IOLs). To analyze the optical quality of IOLs it is necessary to test them in an optical bench that agrees with the ISO119679-2 1999 standard (Ophthalmic implants. Intraocular lenses. Part 2. Optical Properties and Test Methods). In addition to analyze the IOLs according to the ISO standard, we have designed an optical bench that allows us to simulate the conditions of a real human eye. To do that, we will use artificial corneas with different amounts of optical aberrations and several illumination sources with different spectral distributions. Moreover, the design of the test bench includes the possibility of testing the IOLs under off-axis conditions as well as in the presence of decentration and/or tilt. Finally, the optical imaging quality of the IOLs is assessed by using common metrics like the Modulation Transfer Function (MTF), the Point Spread Function (PSF) and/or the Strehl ratio (SR), or via registration of the IOL's wavefront with a Hartmann-Shack sensor and its analysis through expansion in Zernike polynomials.
Reliability of a Single Light Source Purkinjemeter in Pseudophakic Eyes.
Janunts, Edgar; Chashchina, Ekaterina; Seitz, Berthold; Schaeffel, Frank; Langenbucher, Achim
2015-08-01
To study the reliability of Purkinje image analysis for assessment of intraocular lens tilt and decentration in pseudophakic eyes. The study comprised 64 eyes of 39 patients. All eyes underwent phacoemulsification with intraocular lens implanted in the capsular bag. Lens decentration and tilt were measured multiple times by an infrared Purkinjemeter. A total of 396 measurements were performed 1 week and 1 month postoperatively. Lens tilt (Tx, Ty) and decentration (Dx, Dy) in horizontal and vertical directions, respectively, were calculated by dedicated software based on regression analysis for each measurement using only four images, and afterward, the data were averaged (mean values, MV) for repeated sequence of measurements. New software was designed by us for recalculating lens misalignment parameters offline, using a complete set of Purkinje images obtained through the repeated measurements (9 to 15 Purkinje images) (recalculated values, MV'). MV and MV' were compared using SPSS statistical software package. MV and MV' were found to be highly correlated for the Tx and Ty parameters (R2 > 0.9; p < 0.001), moderately correlated for the Dx parameter (R2 > 0.7; p < 0.001), and weakly correlated for the Dy parameter (R2 = 0.23; p < 0.05). Reliability was high (Cronbach α > 0.9) for all measured parameters. Standard deviation values were 0.86 ± 0.69 degrees, 0.72 ± 0.65 degrees, 0.04 ± 0.05 mm, and 0.23 ± 0.34 mm for Tx, Ty, Dx, and Dy, respectively. The Purkinjemeter demonstrated high reliability and reproducibility for lens misalignment parameters. To further improve reliability, we recommend capturing at least six Purkinje images instead of three.
Psychophysical Vision Simulation of Diffractive Bifocal and Trifocal Intraocular Lenses
Brezna, Wolfgang; Lux, Kirsten; Dragostinoff, Nikolaus; Krutzler, Christian; Plank, Nicole; Tobisch, Rainer; Boltz, Agnes; Garhöfer, Gerhard; Told, Reinhard; Witkowska, Katarzyna; Schmetterer, Leopold
2016-01-01
Purpose The visual performance of monofocal, bifocal, and trifocal intraocular lenses was evaluated by human individuals using a vision simulator device. This allowed investigation of the visual impression after cataract surgery, without the need actually to implant the lenses. Methods The randomized, double-masked, three-way cross-over study was conducted on 60 healthy male and female subjects aged between 18 and 35 years. Visual acuity (Early Treatment Diabetic Retinopathy Study; ETDRS) and contrast sensitivity tests (Pelli-Robson) under different lighting conditions (luminosities from 0.14–55 cd/m2, mesopic to photopic) were performed at different distances. Results Visual acuity tests showed no difference for corrected distance visual acuity data of bi- and trifocal lens prototypes (P = 0.851), but better results for the trifocal than for the bifocal lenses at distance corrected intermediate (P = 0.021) and distance corrected near visual acuity (P = 0.044). Contrast sensitivity showed no differences between bifocal and trifocal lenses at the distant (P = 0.984) and at the near position (P = 0.925), but better results for the trifocal lens at the intermediate position (P = 0.043). Visual acuity and contrast sensitivity showed a strong dependence on luminosity (P < 0.001). Conclusions At all investigated distances and all lighting conditions, the trifocal lens prototype often performed better, but never worse than the bifocal lens prototype. Translational Relevance The vision simulator can fill the gap between preclinical lens development and implantation studies by providing information of the perceived vision quality after cataract surgery without implantation. This can reduce implantation risks and promotes the development of new lens concepts due to the cost effective test procedure. PMID:27777828
Inoue, Makoto; Noda, Toru; Mihashi, Toshifumi; Ohnuma, Kazuhiko; Bissen-Miyajima, Hiroko; Hirakata, Akito
2011-04-01
To evaluate the quality of the image of a grating target placed in a model eye viewed through multifocal intraocular lenses (IOLs). Laboratory investigation. Refractive (NXG1 or PY60MV) or diffractive (ZM900 or SA60D3) multifocal IOLs were placed in a fluid-filled model eye with human corneal aberrations. A United States Air Force resolution target was placed on the posterior surface of the model eye. A flat contact lens or a wide-field contact lens was placed on the cornea. The contrasts of the gratings were evaluated under endoillumination and compared to those obtained through a monofocal IOL. The grating images were clear when viewed through the flat contact lens and through the central far-vision zone of the NXG1 and PY60MV, although those through the near-vision zone were blurred and doubled. The images observed through the central area of the ZM900 with flat contact lens were slightly defocused but the images in the periphery were very blurred. The contrast decreased significantly in low frequencies (P<.001). The images observed through the central diffractive zone of the SA60D3 were slightly blurred, although the images in the periphery were clearer than that of the ZM900. The images were less blurred in all of the refractive and diffractive IOLs with the wide-field contact lens. Refractive and diffractive multifocal IOLs blur the grating target but less with the wide-angle viewing system. The peripheral multifocal optical zone may be more influential on the quality of the images with contact lens system. Copyright © 2011 Elsevier Inc. All rights reserved.
Validity of automated refraction after segmented refractive multifocal intraocular lens implantation
Albarrán-Diego, César; Muñoz, Gonzalo; Rohrweck, Stephanie; García-Lázaro, Santiago; Albero, José Ricardo
2017-01-01
AIM To evaluate the clinical utility of automated refraction (AR) and keratometry (KR) compared with subjective or manifest refraction (MR) after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH) refractive multifocal intraocular lens (IOL). METHODS Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. RESULTS Analysis showed excellent repeatability of the AR measurements. Linear regression of AR versus MR showed good correlation for sphere and spherical equivalent, whereas the correlation for astigmatism was low. The mean difference AR-MR was -1.28±0.29 diopters (D) for sphere. Astigmatism showed better correlation between KR and MR. CONCLUSION We suggest AR sphere plus 1.25 D and the KR cylinder as the starting point for MR in eyes with a Lentis Mplus X multifocal IOL. If AR measurements are equal to MR, decentration of the IOL should be suspected. PMID:29181318
Albarrán-Diego, César; Muñoz, Gonzalo; Rohrweck, Stephanie; García-Lázaro, Santiago; Albero, José Ricardo
2017-01-01
To evaluate the clinical utility of automated refraction (AR) and keratometry (KR) compared with subjective or manifest refraction (MR) after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH) refractive multifocal intraocular lens (IOL). Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. Analysis showed excellent repeatability of the AR measurements. Linear regression of AR versus MR showed good correlation for sphere and spherical equivalent, whereas the correlation for astigmatism was low. The mean difference AR-MR was -1.28±0.29 diopters (D) for sphere. Astigmatism showed better correlation between KR and MR. We suggest AR sphere plus 1.25 D and the KR cylinder as the starting point for MR in eyes with a Lentis Mplus X multifocal IOL. If AR measurements are equal to MR, decentration of the IOL should be suspected.
An RFID-based on-lens sensor system for long-term IOP monitoring.
Hsu, Shun-Hsi; Chiou, Jin-Chern; Liao, Yu-Te; Yang, Tzu-Sen; Kuei, Cheng-Kai; Wu, Tsung-Wei; Huang, Yu-Chieh
2015-01-01
In this paper, an RFID-based on-lens sensor system is proposed for noninvasive long-term intraocular pressure monitoring. The proposed sensor IC, fabricated in a 0.18um CMOS process, consists of capacitive sensor readout circuitry, RFID communication circuits, and digital processing units. The sensor IC is integrated with electroplating capacitive sensors and a receiving antenna on the contact lens. The sensor IC can be wirelessly powered, communicate with RFID compatible equipment, and perform IOP measurement using on-lens capacitive sensor continuously from a 2cm distance while the incident power from an RFID reader is 20 dBm. The proposed system is compatible to Gen2 RFID protocol, extending the flexibility and reducing the self-developed firmware efforts.
The treatment of malignant glaucoma in nanophthalmos: a case report.
Wang, Jie; Du, Ergang; Tang, Jinfei
2018-02-23
The management of eyes with nanophthalmos is a dilemma for ophthalmologists due to various complications, especial the eye with malignant glaucoma. We report a case of effective treatment for malignant glaucoma in nanophthalmos. An 82-year-old man was performed phacoemulsification in the right eye with normal ocular pressure and nanophthalmos. The surgery was uneventful: an intraocular lens (IOL) was placed and centered in the capsular bag. 2 months later, the patient presented with malignant glaucoma, and the intraocular pressure fluctuated between 18.6 mmHg and 30.8 mmHg with antiglaucoma medications. The patient did not respond to surgical peripheral iridotomy and goniosynechialysis. Then a single treatment with laser peripheral lens posterior capsulotomy and vitreous anterior membranectomy was performed. The intraocular pressure normalized, and the anterior chamber deepened within 24 h. The patient's condition remained stable for 9 months with no further treatment, and his Snellen corrected distance visual acuity was 20/50. The left eye of this patient was treated by combined surgery including phacoemulsification, IOL implantation, anterior vitrectomy, surgical peripheral iridotomy (PI), and goniosynechialysis. No intraoperative or postoperative complications were observed. This case suggests that it is essential to choose a suitable treatment for nanophthalmos patients to deal with malignant glaucoma and to reduce the incidence of malignant glaucoma.
Jones, Jason J; Chu, Jeffrey; Graham, Jacob; Zaluski, Serge; Rocha, Guillermo
2016-01-01
The aim of this study was to evaluate the operational impact of using preloaded intraocular lens (IOL) delivery systems compared with manually loaded IOL delivery processes during routine cataract surgeries. Time and motion data, staff and surgery schedules, and cost accounting reports were collected across three sites located in the US, France, and Canada. Time and motion data were collected for manually loaded IOL processes and preloaded IOL delivery systems over four surgery days. Staff and surgery schedules and cost accounting reports were collected during the 2 months prior and after introduction of the preloaded IOL delivery system. The study included a total of 154 routine cataract surgeries across all three sites. Of these, 77 surgeries were performed using a preloaded IOL delivery system, and the remaining 77 surgeries were performed using a manual IOL delivery process. Across all three sites, use of the preloaded IOL delivery system significantly decreased mean total case time by 6.2%-12.0% (P<0.001 for data from Canada and the US and P<0.05 for data from France). Use of the preloaded delivery system also decreased surgeon lens time, surgeon delays, and eliminated lens touches during IOL preparation. Compared to a manual IOL delivery process, use of a preloaded IOL delivery system for cataract surgery reduced total case time, total surgeon lens time, surgeon delays, and eliminated IOL touches. The time savings provided by the preloaded IOL delivery system provide an opportunity for sites to improve routine cataract surgery throughput without impacting surgeon or staff capacity.
Advances in lens implant technology
Kampik, Anselm; Dexl, Alois K.; Zimmermann, Nicole; Glasser, Adrian; Baumeister, Martin; Kohnen, Thomas
2013-01-01
Cataract surgery is one of the oldest and the most frequent outpatient clinic operations in medicine performed worldwide. The clouded human crystalline lens is replaced by an artificial intraocular lens implanted into the capsular bag. During the last six decades, cataract surgery has undergone rapid development from a traumatic, manual surgical procedure with implantation of a simple lens to a minimally invasive intervention increasingly assisted by high technology and a broad variety of implants customized for each patient’s individual requirements. This review discusses the major advances in this field and focuses on the main challenge remaining – the treatment of presbyopia. The demand for correction of presbyopia is increasing, reflecting the global growth of the ageing population. Pearls and pitfalls of currently applied methods to correct presbyopia and different approaches under investigation, both in lens implant technology and in surgical technology, are discussed. PMID:23413369
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-15
...-through devices, brachytherapy sources, intraoperative radiation therapy (IORT), brachytherapy composite... Modulated Radiation Therapy I/OCE Integrated Outpatient Code Editor IOL Intraocular lens IOM Institute of Medicine IORT Intraoperative radiation treatment IPF Inpatient Psychiatric Facility IPPS [Hospital...
Aviation accident risk for airmen with aphakia and artificial lens implants.
DOT National Transportation Integrated Search
1993-06-01
Airmen with aphakia and intraocular (IOL) implants who on a case-by-case basis, may obtain a waiver for a medical certificate have been previously associated with higher aviation accident rates when compared to the total civil airman population. This...
Gundersen, Kjell G; Potvin, Rick
2017-01-01
To compare two different diffractive trifocal intraocular lens (IOL) designs, evaluating longer-term refractive outcomes, visual acuity (VA) at various distances, low contrast VA and quality of vision. Patients with binocularly implanted trifocal IOLs of two different designs (FineVision [FV] and Panoptix [PX]) were evaluated 6 months to 2 years after surgery. Best distance-corrected and uncorrected VA were tested at distance (4 m), intermediate (80 and 60 cm) and near (40 cm). A binocular defocus curve was collected with the subject's best distance correction in place. The preferred reading distance was determined along with the VA at that distance. Low contrast VA at distance was also measured. Quality of vision was measured with the National Eye Institute Visual Function Questionnaire near subset and the Quality of Vision questionnaire. Thirty subjects in each group were successfully recruited. The binocular defocus curves differed only at vergences of -1.0 D (FV better, P =0.02), -1.5 and -2.00 D (PX better, P <0.01 for both). Best distance-corrected and uncorrected binocular vision were significantly better for the PX lens at 60 cm ( P <0.01) with no significant differences at other distances. The preferred reading distance was between 42 and 43 cm for both lenses, with the VA at the preferred reading distance slightly better with the PX lens ( P =0.04). There were no statistically significant differences by lens for low contrast VA ( P =0.1) or for quality of vision measures ( P >0.3). Both trifocal lenses provided excellent distance, intermediate and near vision, but several measures indicated that the PX lens provided better intermediate vision at 60 cm. This may be important to users of tablets and other handheld devices. Quality of vision appeared similar between the two lens designs.
Farooqui, Javed Hussain; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo
2015-01-01
Purpose Visual performance following toric intraocular lens implantation for cataract with moderate and severe astigmatism. Setting Cataract services, Shroff Eye Centre, New Delhi, India. Design Case series. Method This prospective study included 64 eyes of 40 patients with more than 1.50 dioptre (D) of pre-existing corneal astigmatism undergoing phacoemulsification with implantation of the AcrySof® toric IntraOcular Lens (IOL). The unaided visual acuity (UCVA), best corrected visual acuity (BCVA), residual refractive sphere and refractive cylinders were evaluated. Toric IOL axis and alignment error was measured by slit lamp method and Adobe Photoshop (version 7) method. Patient satisfaction was evaluated using a satisfaction questionnaire at 3 months. Results The mean residual refractive astigmatism was 0.57 D at the final follow-up of 3 months. Mean alignment error was 3.44 degrees (SD = 2.60) by slit lamp method and 3.88 degrees (SD = 2.86) by Photoshop method. Forty-six (71.9%) eyes showed misalignment of 5 degrees or less, and 60 (93.8%) eyes showed misalignment of 10 degrees or less. The mean log MAR UCVA at 1st post-op day was 0.172 (SD = 0.02), on 7th post-op day was 0.138 (SD = 0.11), and on 30th post-op day was 0.081 (SD = 0.11). The mean log MAR BCVA at three months was −0.04 (SD = 0.76). Conclusion We believe that implantation of AcrySof® toric IOL is an effective, safe and predictable method to correct high amounts of corneal astigmatism during cataract surgery. PMID:26586976
Bae, Hyoung Won; Lee, Yun Ha; Kim, Do Wook; Lee, Taekjune; Hong, Samin; Seong, Gong Je; Kim, Chan Yun
2016-08-01
The objective of the study is to examine the effect of trabeculectomy on intraocular lens power calculations in patients with open-angle glaucoma (OAG) undergoing cataract surgery. The design is retrospective data analysis. There are a total of 55 eyes of 55 patients with OAG who had a cataract surgery alone or in combination with trabeculectomy. We classified OAG subjects into the following groups based on surgical history: only cataract surgery (OC group), cataract surgery after prior trabeculectomy (CAT group), and cataract surgery performed in combination with trabeculectomy (CCT group). Differences between actual and predicted postoperative refractive error. Mean error (ME, difference between postoperative and predicted SE) in the CCT group was significantly lower (towards myopia) than that of the OC group (P = 0.008). Additionally, mean absolute error (MAE, absolute value of ME) in the CAT group was significantly greater than in the OC group (P = 0.006). Using linear mixed models, the ME calculated with the SRK II formula was more accurate than the ME predicted by the SRK T formula in the CAT (P = 0.032) and CCT (P = 0.035) groups. The intraocular lens power prediction accuracy was lower in the CAT and CCT groups than in the OC group. The prediction error was greater in the CAT group than in the OC group, and the direction of the prediction error tended to be towards myopia in the CCT group. The SRK II formula may be more accurate in predicting residual refractive error in the CAT and CCT groups. © 2016 Royal Australian and New Zealand College of Ophthalmologists.
Linz, Katharina; Attia, Mary S A; Khoramnia, Ramin; Tandogan, Tamer; Kretz, Florian T; Auffarth, Gerd Uwe
2016-08-01
To evaluate functional results and reading performance using the Salzburg Reading Desk after implantation of a sector-shaped near-embedded, rotational asymmetrical multifocal intraocular lens (IOL) and a multifocal toric IOL with a +3.00 diopter (D) near addition. In a prospective study, the LentisMplus and Mplus toric IOLs (Oculentis GmbH, Berlin, Germany) were implanted in 34 eyes of 18 patients at the University Eye Hospital of Heidelberg. Uncorrected and corrected distance visual acuity (UDVA, CDVA) and uncorrected and corrected near visual acuity (UNVA, CNVA) were evaluated using standardized visual acuity charts (ETDRS). The Salzburg Reading Desk was used to analyze unilateral and bilateral uncorrected and corrected reading acuity, reading distance, reading speed, and the smallest log-scaled print size that could be read effectively at a set (40 cm/80 cm) and subjective chosen near and intermediate distance. Postoperatively, the median UDVA was 0.08 logMAR (20/25 Snellen) and the median CDVA was 0.01 logMAR (20/20 Snellen). The median UNVA was 0.12 logMAR (20/25 Snellen) and the median CNVA was 0.03 logMAR (20/20 Snellen). The median uncorrected reading acuity measured with the Salzburg Reading Desk for near distance at 40 cm was 0.18 logMAR (20/32 Snellen). The subjectively preferred near distance was 39 cm and revealed similar visual acuity results. The best reading acuity for intermediate distance with a median of 0.22 logMAR (20/32 Snellen) was achieved at a median distance of 62 cm. Reading performance of the multifocal IOL corresponded for near standardized and individual distance, whereas reading function was better at the patient's preferred intermediate distance. [J Refract Surg. 2016;32(8):526-532.]. Copyright 2016, SLACK Incorporated.
Zhang, Lijun; Sy, Mary Ellen; Mai, Harry; Yu, Fei; Hamilton, D Rex
2015-01-01
To compare the prediction error after toric intraocular lens (IOL) (Acrysof IQ) implantation using corneal astigmatism measurements obtained with an IOLMaster automated keratometer and a Galilei dual rotating camera Scheimpflug-Placido tomographer. Jules Stein Eye Institute, University of California Los Angeles, Los Angeles, California, USA. Retrospective case series. The predicted residual astigmatism after toric IOL implantation was calculated using preoperative astigmatism values from an automated keratometer and the total corneal power (TCP) determined by ray tracing through the measured anterior and posterior corneal surfaces using dual Scheimpflug-Placido tomography. The prediction error was calculated as the difference between the predicted astigmatism and the manifest astigmatism at least 1 month postoperatively. The calculations included vector analysis. The study evaluated 35 eyes (35 patients). The preoperative corneal posterior astigmatism mean magnitude was 0.33 diopter (D) ± 0.16 (SD) (vector mean 0.23 × 176). Twenty-six eyes (74.3%) had with-the-rule (WTR) posterior astigmatism. The postoperative manifest refractive astigmatism mean magnitude was 0.38 ± 0.18 D (vector mean 0.26 × 171). There was no statistically significant difference in the mean magnitude prediction error between the automated keratometer and TCP techniques. However, the automated keratometer method tended to overcorrect WTR astigmatism and undercorrect against-the-rule (ATR) astigmatism. The TCP technique lacked these biases. The automated keratometer and TCP methods for estimating the magnitude of corneal astigmatism gave similar results. However, the automated keratometer method tended to overcorrect WTR astigmatism and undercorrect ATR astigmatism. Dr. Hamilton has received honoraria for educational lectures from Ziemer Ophthalmic Systems. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Matsuda, M; Kinoshita, S; Ohashi, Y; Shimomura, Y; Ohguro, N; Okamoto, H; Omoto, T; Hosotani, H; Yoshida, H
1991-01-01
We conducted a randomised prospective controlled study to determine the effects of a glucose glutathione bicarbonate solution (BSS Plus) and a citrate acetate bicarbonate solution (S-MA2) on the corneal endothelium in patients undergoing extracapsular cataract extraction with posterior chamber lens implantation. One eye of each patient was randomly assigned to receive BSS Plus, and the other eye to receive S-MA2. BSS Plus caused significantly less corneal swelling on the first postoperative day than did S-MA2. There was no difference between the two solutions in their effect on corneal thickness one week and one month postoperatively. Computer assisted morphometric analysis of wide-field specular microscopic photographs demonstrated minimal changes in endothelial morphological characteristics in the eyes irrigated with BSS Plus. By comparison S-MA2, caused a significant loss of endothelial cells and a marked reduction in the figure coefficient. These results indicated that BSS Plus has a clinical advantage over S-MA2 with respect to the corneal endothelium. PMID:1873266
Giers, Bert C; Khoramnia, Ramin; Weber, Lea F; Tandogan, Tamer; Auffarth, Gerd U
2016-03-01
We present the case of a 56-year-old woman with moderate myopia and bilateral cataract who had cataract extraction and intraocular lens (IOL) implantation. Due to the patient's desire for spectacle independence, a trifocal IOL with toric correction for astigmatism was implanted. During the follow-up, it became obvious that the implanted IOL had rotated and tilted due to insufficient fixation in the large capsular bag of the myopic eye. An IOL explantation was therefore performed, and the original IOL was exchanged for a bifocal toric IOL with a larger overall diameter. Stable fixation of the IOL in the capsular bag was achieved, and after surgery in the second eye, the patient recovered good bilateral vision. This case illustrates the need for careful selection of IOL diameter and sizing even in patients with moderate myopia due to the potentially larger ocular dimensions in these patients. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Yanoga, Fatoumata; Garcia-Gonzalez, Jose M; Greenwald, Mark; Shapiro, Michael J; Blair, Michael P
2017-01-01
To report a case of fungal endophthalmitis from reactivation of a dormant lenticular fungal abscess in a severely premature infant. Single retrospective case report. A female born at 23 and 6/7 weeks and weighing 620 g was diagnosed at age 29 weeks post menstrual age with persistent tunica vasculosa lentis, lenticular opacity, and aggressive posterior retinopathy of prematurity, and received bilateral intravitreal injection of bevacizumab. At the time of injection she was receiving systemic antibiotics for sepsis and fungemia. The retinopathy of prematurity regressed, as did the tunica vasculosa lentis, but a small plaque remained on the lens. At 5.5 months of age, patient presented with hypopyon and elevated intraocular pressure. Culture of intraocular fluid demonstrated Candida albicans. Candida lenticular abscess is a rare complication of systemic fungemia in premature infants. Bevacizumab-induced regression of tunica vasculosa lentis may have decreased the ability of systemically administered antifungal medications to reach the colonized lens.
Voltage-controlled IPMC actuators for accommodating intra-ocular lens systems
NASA Astrophysics Data System (ADS)
Horiuchi, Tetsuya; Mihashi, Toshifumi; Fujikado, Takashi; Oshika, Tetsuro; Asaka, Kinji
2017-04-01
An ion polymer-metal composite (IPMC) actuator has unique performance characteristics that were applied in this study for use within the eye. Cataracts are a common eye disease causing clouding of the lens. To treat cataracts, surgeons replace clouded lenses with intraocular lenses (IOLs). However, patients who receive this treatment must still wear reading glasses for tasks requiring close-up vision. We suggest a new voltage-controlled accommodating IOL consisting of an IPMC actuator to change the lens’ focus. We examined the relationship between the displacement performance of an IPMC actuator and the accommodating range of the IOL using in vitro experiments. We show that this system has an accommodating range of approximately 1.15 D under an applied voltage of ±1.2 V. By Lagrange interpolation, we estimate that with an IPMC actuator displacement of 0.14 mm, we can achieve a refractive power of 4 D, which is equivalent to the accommodating range of a 40 year old person.
[Miyake-Apple video analysis of movement patterns of an accommodative intraocular lens implant].
Auffarth, G U; Schmidbauer, J; Becker, K A; Rabsilber, T M; Apple, D J
2002-11-01
The potentially accommodative intraocular lens (IOL) is a new development in IOL design We evaluated the new Humanoptics 1CU accommodative IOL in a laboratory study with human post mortem autopsy eyes. Using the Miyake-Apple posterior view video technique, the movement pattern of the IOL was tested and observed from the posterior perspective. RESULTS. A circular bend at the level of the ciliary body applied slight circular force onto the sclera allowing the relaxation of the zonules. The shift of focus was demonstrated by using a reading target. In addition, viscoelastic was injected into the vitreous resulting in the same anterior movement of the IOL optic. The 1CU Humanoptics accommodative IOL showed potential accommodative behaviour in the laboratory. The accommodative (respectively pseudoaccommodative) effect was based on the anterior shift principle with anterior movement of the IOL-optic in the state of relaxing zonules. Whether this reflects the clinical situation, especially to this extent, must be further evaluated.
Anterior Eye Imaging with Optical Coherence Tomography
NASA Astrophysics Data System (ADS)
Huang, David; Li, Yan; Tang, Maolong
The development of corneal and anterior segment optical coherence tomography (OCT) technology has advanced rapidly in recently years. The scan geometry and imaging wavelength are both important choices to make in designing anterior segment OCT systems. Rectangular scan geometry offers the least image distortion and is now used in most anterior OCT systems. The wavelength of OCT light source affects resolution and penetration. An optimal choice of the OCT imaging wavelength (840, 1,050, or 1,310 nm) depends on the application of interest. Newer generation Fourier-domain OCT technology can provide scan speed 100-1000 times faster than the time-domain technology. Various commercial anterior OCT systems are available on the market. A wide spectrum of diagnostic and surgical applications using anterior segment OCT had been investigated, including mapping of corneal and epithelial thicknesses, keratoconus screening, measuring corneal refractive power, corneal surgery planning and evaluation in LASIK, intracorneal ring implantation, assessment of angle closure glaucoma, anterior chamber biometry and intraocular lens implants, intraocular lens power calculation, and eye bank donor cornea screening.
Management of corneal decompensation 4 decades after Sputnik intraocular lens implantation.
Hirji, Nashila; Nanavaty, Mayank A
2015-01-01
We report an unusual case of corneal decompensation occurring four decades after complicated cataract extraction with implantation of a Sputnik intraocular lens (IOL) and highlight the clinical and practical issues faced in managing corneal decompensation with a Sputnik IOL. A 72-year-old woman presented with deterioration of the vision in her left eye, four decades after intracapsular cataract extraction with Sputnik IOL implantation. Ocular examination revealed diffuse corneal edema and thickened vitreous strands in the anterior chamber. Her best-corrected visual acuity (BCVA) worsened to 6/60 within 3 months. Anterior vitrectomy and inferior iridectomy combined with Desçemet-stripping automated endothelial keratoplasty was performed. The procedure was successful, with the patient achieving best-corrected visual acuity of 6/6 at 8 months postoperatively. Corneal decompensation after Sputnik IOL implantation can occur four decades later. When the historical preoperative visual acuity is good in such cases, careful anterior vitrectomy with Desçemet-stripping automated endothelial keratoplasty provides good visual rehabilitation.
Zafar, Andleeb; Aslanides, Ioannis M; Selimis, Vasileios; Tsoulnaras, Konstantinos I; Tabibian, David; Kymionis, George D
2018-01-01
We report here the case of a patient with anterior segment migration of intravitreal dexamethasone implant as well as its management and outcome. The patient had the following sequence of events: complicated cataract surgery, iris-sutured intraocular lens implant, followed by cystoid macular edema treated with intravitreal Avastin, retinal vein occlusion treated with intravitreal dexamethasone implant, corneal decompensation treated with Descemet stripping automated endothelial keratoplasty (DSAEK), and finally recurrence of macular edema treated with repeated intravitreal dexamethasone implant. Dexamethasone implant had completely dissolved from the eye 12 weeks after insertion without any complication. A conservative approach with regular monitoring in the situation of a quiet anterior segment without any corneal decompensation can provide enough time for the implant to dissolve without causing any complication to the involved eye, avoiding any additional surgical intervention, as presented in this case report. Despite the fact that the implant was left for natural dissolution, there were no adverse effects related to the graft or the eye.
Astigmatism evaluation prior to cataract surgery.
Gupta, Pankaj C; Caty, Jane T
2018-01-01
To evaluate and summarize literature from the past 18 months reporting advancements and issues in astigmatism assessment prior to cataract surgery. New and updated toric calculators and regression formulas offer the opportunity for more accurate lens selection for our patients. Concurrently, improvements in topographic evaluation of corneal keratometry have allowed for a decrease in unplanned residual corneal astigmatism. Measuring posterior corneal astigmatism is especially valuable in eyes with keratoconus when planning to implant toric intraocular lens (IOL) and now allows access to this patient population. Improved accuracy of astigmatism evaluation now occurs with point reflections on the corneal surface along with the latest generation toric lens formulas which integrated posterior corneal astigmatism, predicted lens position, and intended spherical power of the IOL. These improvements can allow for incorporation of toric lenses in keratoconus patients.
Three-dimensional OCT based guinea pig eye model: relating morphology and optics.
Pérez-Merino, Pablo; Velasco-Ocana, Miriam; Martinez-Enriquez, Eduardo; Revuelta, Luis; McFadden, Sally A; Marcos, Susana
2017-04-01
Custom Spectral Optical Coherence Tomography (SOCT) provided with automatic quantification and distortion correction algorithms was used to measure the 3-D morphology in guinea pig eyes (n = 8, 30 days; n = 5, 40 days). Animals were measured awake in vivo under cyclopegia. Measurements showed low intraocular variability (<4% in corneal and anterior lens radii and <8% in the posterior lens radii, <1% interocular distances). The repeatability of the surface elevation was less than 2 µm. Surface astigmatism was the individual dominant term in all surfaces. Higher-order RMS surface elevation was largest in the posterior lens. Individual surface elevation Zernike terms correlated significantly across corneal and anterior lens surfaces. Higher-order-aberrations (except spherical aberration) were comparable with those predicted by OCT-based eye models.
Morphologic compatibility or intraocular lens haptics and the lens capsule.
Nagamoto, T; Eguchi, G
1997-10-01
To evaluate the mechanical relationship between the intraocular lens (IOL) haptic and the capsular bag by quantitatively analyzing the fit of the haptic with the capsule equator and the capsular bag deformity induced by the implanted lens haptics. Division of Morphogenesis, Department of Developmental Biology, National Institute for Basic Biology, Okazaki, Japan. Following implantation of a poly(methyl methacrylate)(PMMA) ring in three excised human capsular bags with continuous curvilinear capsulorhexis (CCC), IOLs with different overall lengths or haptic designs were implanted in the bags and photographed. The straight length of the area of contact between the haptic and the capsule equator on the photographs was measured to provide a quantitative index of in-the-bag fixation and the length from the external margin of the PMMA ring to the external margin of the loop along the maximal diameter of the capsular bag, to indicate the quantitative degree of capsular deformity induced by an IOL. An IOL with modified-C loops produced better fit along the capsule equator and less deformity than an IOL with modified-J loops, and an IOL with an overall length of 12.0 or 12.5 mm produced a sufficiently good fit and less distortion of the capsular bag than an IOL with an overall length over 13.0 mm. An IOL with modified-C loops and an overall length of 12.0 or 12.5 mm is adequate for in-the-bag implantation following CCC.
Ruangsetakit, Varee
2015-11-01
To re-examine relative accuracy of intraocular lens (IOL) power calculation of immersion ultrasound biometry (IUB) and partial coherence interferometry (PCI) based on a new approach that limits its interest on the cases in which the IUB's IOL and PCI's IOL assignments disagree. Prospective observational study of 108 eyes that underwent cataract surgeries at Taksin Hospital. Two halves ofthe randomly chosen sample eyes were implanted with the IUB- and PCI-assigned lens. Postoperative refractive errors were measured in the fifth week. More accurate calculation was based on significantly smaller mean absolute errors (MAEs) and root mean squared errors (RMSEs) away from emmetropia. The distributions of the errors were examined to ensure that the higher accuracy was significant clinically as well. The (MAEs, RMSEs) were smaller for PCI of (0.5106 diopter (D), 0.6037D) than for IUB of (0.7000D, 0.8062D). The higher accuracy was principally contributedfrom negative errors, i.e., myopia. The MAEs and RMSEs for (IUB, PCI)'s negative errors were (0.7955D, 0.5185D) and (0.8562D, 0.5853D). Their differences were significant. The 72.34% of PCI errors fell within a clinically accepted range of ± 0.50D, whereas 50% of IUB errors did. PCI's higher accuracy was significant statistically and clinically, meaning that lens implantation based on PCI's assignments could improve postoperative outcomes over those based on IUB's assignments.
Ruiz, Thaís; Campos, Wilma N S; Peres, Thalita P S; Gonçalves, Gentil F; Ferraz, Rosa H S; Néspoli, Pedro E B; Sousa, Valéria R F; Ribeiro, Alexandre P
2015-01-01
The aim was to determine the intraocular pressure (IOP), the ultrasonographic and echobiometric findings in the eyes of juvenile Yacare caiman (Caiman yacare). Twenty-two healthy caimans from a breeding farm in Brazilian Pantanal. Intraocular pressure was measured under physical restraint and topical anesthesia by applanation tonometry. Five individual measurements of each eye were recorded by the same examiner. B-mode ultrasonography was performed with a 10-MHz linear transducer, and the anterior chamber depth, lens thickness, vitreous depth, and axial globe length were measured. Unpaired and paired t-tests were used to assess data. Pearson's test was used to assess correlations between IOP and ocular structures (P < 0.05). Mean ± SD IOP of the 44 eyes studied was 9.56 ± 2.69 mmHg, (range 5.4-15.6 mmHg). IOP did not differ significantly between right and left eyes or between genders (P > 0.05). Echobiometric measurements did not differ significantly between eyes and genders (P > 0.05). Intraocular structures measured in male and female subjects were, respectively, 2.61 ± 0.13 and 2.55 ± 0.18 mm for anterior chamber depth, 7.60 ± 0.17 and 7.54 ± 0.20 mm for lens thickness, 6.83 ± 0.20 and 6.90 ± 0.22 mm for vitreous chamber depth, and 17.55 ± 0.25 and 17.54 ± 0.29 mm for axial globe length. Correlations were not observed (P > 0.05). Reference values of tonometry and distances of intraocular structures of Yacare caiman were described. IOP did not correlate with echobiometric measurements in this crocodilian. The ultrasonographic appearance was similar to other domestic and wild species. © 2014 American College of Veterinary Ophthalmologists.
Surface cytologic features on intraocular lenses: can increased biocompatibility have disadvantages?
Hollick, E J; Spalton, D J; Ursell, P G
1999-07-01
To compare the anterior surface cytologic features and effect on blood-aqueous barrier of polymethyl methacrylate, silicone, and hydrogel intraocular lens (IOL) implants to give an indication of their biocompatibility. This prospective study was performed at an English-teaching hospital. Ninety eyes were randomized to receive a polymethyl methacrylate, silicone, or hydrogel implant. A standardized surgical protocol was performed by a single surgeon using phacoemulsification. Patients were seen at intervals for 1 year. Measurements of visual acuity, contrast sensitivity, and anterior chamber laser flare and cells were obtained; and an assessment of lens cytologic features using specular microscopy of the anterior IOL surface was performed. Visual acuity and contrast sensitivity were not significantly different among the 3 groups. Hydrogel IOLs were associated with fewer inflammatory cells on their surface than polymethyl methacrylate and silicone IOLs (P<.001), but with significantly more lens epithelial cells (LECs) (P<.001). Patients with hydrogel implants without LECs had greater blood-aqueous barrier breakdown than those with LECs. The hydrogel IOLs were associated with a reduced inflammatory cell reaction but had many more LECs on their anterior surface. Those IOLs associated with increased blood-aqueous barrier damage did not develop LECs. If an IOL is too biocompatible, then it may incite the growth of LECs over its surface, which could have disadvantages.
Kretz, Florian T A; Müller, Matthias; Gerl, Matthias; Gerl, Ralf H; Auffarth, Gerd U
2015-08-21
To evaluate binocular visual outcome for near, intermediate and distance compared to monocular visual outcome at the same distances in patients implanted with a diffractive trifocal intraocular lens (IOL). The study comprised of 100 eyes of 50 patients that underwent bilateral refractive lens exchange or cataract surgery with implantation of a multifocal diffractive IOL (AT LISA tri 839MP, Carl Zeiss Meditech, Germany). A complete ophthalmological examination was performed preoperatively and 3 month postoperatively. The main outcome measures were monocular and binocular uncorrected distance (UDVA), corrected distance (CDVA), uncorrected intermediate (UIVA), and uncorrected near visual acuities (UNVA), keratometry, and manifest refraction. The mean age was 59.28 years ± 9.6 [SD] (range 44-79 years), repectively. There was significant improvement in UDVA, UIVA, UNVA and CDVA. Comparing the monocular results to the binocular results there was a statistical significant better binocular outcome in all distances (UDVA p = 0.036; UIVA p < 0.0001; UNVA p = 0.001). The postoperative manifest refraction was in 86 % of patients within ± 0.50 [D]. The trifocal IOL improved near, intermediate, and distance vision compared to preoperatively. In addition a statistical significant increase for binocular visual function in all distances could be found. German Clinical Trials Register (DRKS) DRKS00007837.
Ultra-widefield retinal imaging through a black intraocular lens.
Yusuf, Imran H; Fung, Timothy H M; Patel, Chetan K
2015-09-01
To evaluate the feasibility of ultra-widefield retinal imaging in patients with near infrared (IR)-transmitting black intraocular lenses (IOLs). Oxford Eye Hospital, Oxford, United Kingdom. Laboratory evaluation of a diagnostic technology with interventional case report. The field of retinal imaging through a Morcher poly(methyl methacrylate) (PMMA) black IOL was determined in a purpose-built adult schematic model eye with the HRA2 Spectralis confocal scanning laser ophthalmoscope using standard imaging, Staurenghi retina lens-assisted imaging, and ultra-widefield noncontact imaging. Retinal imaging using each modality was then performed on a patient implanted with another Morcher PMMA black IOL model. Ultra-widefield noncontact imaging and lens-assisted imaging captured up to 150 degrees of field (versus 40 degrees with a standard confocal scanning laser ophthalmoscope). Ultra-widefield retinal images were successfully acquired in a patient eye with a black IOL. This study has identified the first ultra-widefield retinal imaging modalities for patients with near IR-transmitting black IOLs. Should larger studies confirm this finding, noncontact ultra-widefield confocal scanning laser ophthalmoscopy might be considered the gold standard imaging technique for retinal surveillance in patients with near IR-transmitting black IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Tan, Xuhua; Zhan, Jiezhao; Zhu, Yi; Cao, Ji; Wang, Lin; Liu, Sa; Wang, Yingjun; Liu, Zhenzhen; Qin, Yingyan; Wu, Mingxing; Liu, Yizhi; Ren, Li
2017-01-01
Biocompatibility of intraocular lens (IOL) is critical to vision reconstruction after cataract surgery. Foldable hydrophobic acrylic IOL is vulnerable to the adhesion of extracellular matrix proteins and cells, leading to increased incidence of postoperative inflammation and capsule opacification. To increase IOL biocompatibility, we synthesized a hydrophilic copolymer P(MPC-MAA) and grafted the copolymer onto the surface of IOL through air plasma treatment. X-ray photoelectron spectroscopy, atomic force microscopy and static water contact angle were used to characterize chemical changes, topography and hydrophilicity of the IOL surface, respectively. Quartz crystal microbalance with dissipation (QCM-D) showed that P(MPC-MAA) modified IOLs were resistant to protein adsorption. Moreover, P(MPC-MAA) modification inhibited adhesion and proliferation of lens epithelial cells (LECs) in vitro. To analyze uveal and capsular biocompatibility in vivo, we implanted the P(MPC-MAA) modified IOLs into rabbits after phacoemulsification. P(MPC-MAA) modification significantly reduced postoperative inflammation and anterior capsule opacification (ACO), and did not affect posterior capsule opacification (PCO). Collectively, our study suggests that surface modification by P(MPC-MAA) can significantly improve uveal and capsular biocompatibility of hydrophobic acrylic IOL, which could potentially benefit patients with blood-aqueous barrier damage. PMID:28084469
Monteiro, Tiago; Soares, Andreia; Leite, Ricardo Dourado; Franqueira, Nuno; Faria-Correia, Fernando; Vaz, Fernando
2018-01-01
To evaluate and compare the changes in refraction and effective intraocular lens (IOL) position between a plate-haptic IOL and a c-loop single-piece IOL after neodymium-doped yttrium aluminium garnet (YAG) laser posterior capsulotomy. In a prospective study, anterior chamber depth and subjective refraction were measured in 110 pseudophakic eyes from 110 patients, before and 1 month after YAG laser capsulotomy. Patients were divided into 2 groups according to the IOL design: group 1 (plate-haptic acrylic hydrophilic AT LISA tri 839MP ® ) and group 2 (c-loop acrylic hydrophobic single-piece AcrySof ® SA60AT). Lens position was obtained through optical coherence biometry (Biograph WaveLight OB820 ® ). YAG laser capsulotomy was performed 37.8±9.8 months after surgery in group 1 and 40.6±8.6 months in group 2 ( p =0.125). Significant changes were found in the lens effective position after treatment in the 2 groups. The YAG posterior capsulotomy led to a change of anterior chamber depth in group 1 from 4.03±0.32 mm to 3.86±0.34 mm ( p =0.02) and in group 2 from 4.03±0.37 mm to 4.14±0.45 mm ( p =0.025). After YAG laser posterior capsulotomy, no significant changes were observed in mean spherical equivalent, sphere or cylinder for both groups ( p >0.05). YAG laser posterior capsulotomy can induce a significant change in the IOL position according to the IOL type; however, the refractive change after treatment is clinically insignificant.
Berdahl, John P; Hardten, David R; Kramer, Brent A; Potvin, Richard
2017-03-01
To analyze correlations between residual refractive cylinder (and its correction through lens reorientation) with the sphere and cylinder power of the toric intraocular lens (IOL) implanted. An online toric back-calculator (www.astigmatismfix.com) allows users to input toric IOL planning data, along with postoperative IOL orientation and refractive results; these data are used to determine the optimal orientation of the IOL to reduce refractive astigmatism. This was a retrospective data analysis; aggregate historical data were extracted from this calculator to investigate the relationship between residual refractive astigmatism and IOL cylinder and sphere power. A total of 12,812 records, 4,619 of which included IOL sphere power, were available for analysis. There was no significant effect of sphere power on residual refractive astigmatism (P = .25), but lower IOL cylinder powers were associated with significantly lower residual refractive astigmatism (P < .05). The difference between the intended and ideal orientation was higher in the lower IOL cylinder power groups (P < .01). Overcorrection of astigmatism was significantly more likely with higher IOL cylinder power (P < .01), but not with sphere power (P = .33). Reorientation to correct residual refractive cylinder to less than 0.50 diopters (D) was more successful with IOL cylinder powers of 1.50 D or less (P < .01); IOL sphere power had no apparent effect. There were significant effects of IOL cylinder power on residual refractive astigmatism, the difference between intended and ideal orientation, the likelihood of overcorrection, and the likelihood of astigmatism reduction with lens reorientation. IOL sphere power appeared to have no such effects. [J Refract Surg. 2017;33(3):157-162.]. Copyright 2017, SLACK Incorporated.
Monteiro, Tiago; Soares, Andreia; Leite, Ricardo Dourado; Franqueira, Nuno; Faria-Correia, Fernando; Vaz, Fernando
2018-01-01
Purpose To evaluate and compare the changes in refraction and effective intraocular lens (IOL) position between a plate-haptic IOL and a c-loop single-piece IOL after neodymium-doped yttrium aluminium garnet (YAG) laser posterior capsulotomy. Methods In a prospective study, anterior chamber depth and subjective refraction were measured in 110 pseudophakic eyes from 110 patients, before and 1 month after YAG laser capsulotomy. Patients were divided into 2 groups according to the IOL design: group 1 (plate-haptic acrylic hydrophilic AT LISA tri 839MP®) and group 2 (c-loop acrylic hydrophobic single-piece AcrySof® SA60AT). Lens position was obtained through optical coherence biometry (Biograph WaveLight OB820®). Results YAG laser capsulotomy was performed 37.8±9.8 months after surgery in group 1 and 40.6±8.6 months in group 2 (p=0.125). Significant changes were found in the lens effective position after treatment in the 2 groups. The YAG posterior capsulotomy led to a change of anterior chamber depth in group 1 from 4.03±0.32 mm to 3.86±0.34 mm (p=0.02) and in group 2 from 4.03±0.37 mm to 4.14±0.45 mm (p=0.025). After YAG laser posterior capsulotomy, no significant changes were observed in mean spherical equivalent, sphere or cylinder for both groups (p>0.05). Conclusion YAG laser posterior capsulotomy can induce a significant change in the IOL position according to the IOL type; however, the refractive change after treatment is clinically insignificant. PMID:29593378
Intraocular pressure measurement over soft contact lens by rebound tonometer: a comparative study
Nacaroglu, Senay Asik; Un, Emine Seker; Ersoz, Mehmet Giray; Tasci, Yelda
2015-01-01
AIM To evaluate the intraocular pressure (IOP) measurements by Icare rebound tonometer over a contact lens in comparison with Goldmann applanation tonometry (GAT). METHODS Fifty patients using contact lens were included in this study. One of the eyes of the patients was selected randomly and their IOP were measured by rebound tonometer with and without contact lens (RTCL, RT respectively) and by GAT, as well as their central corneal thickness (CCT) by optical pachymeter. The results of both methods were compared by correlation analysis, general linear method repeated measure and Bland-Altman analysis. RESULTS Mean IOP values measured by RTCL, RT and GAT were 15.68±3.7, 14.50±3.4 and 14.16±2.8 (P<0.001), respectively. Mean IOP by RTCL was significantly higher than the measurements implemented by RT and GAT (P<0.001), while there was no difference between the measurements by GAT and RT (P=0.629). There was a good level of positive correlation between GAT and RTCL as well as RT (r=0.786 P<0.001, r=0.833 P<0.001, respectively). We have observed that CCT increase did not show any correlation with the differences of the measurements between RTCL and RT (P=0.329), RTCL and GAT (P=0.07) as well as RT and GAT (P=0.189) in linear regression model. CONCLUSION The average of the measurements over contact lens by rebound tonometer was found to be higher than what was measured by GAT. Although this difference is statistically significant, it may be clinically negligible in the normal population. PMID:26086004
Güell, José Luis; Morral, Merce; Gris, Oscar; Gaytan, Javier; Sisquella, Maite; Manero, Felicidad
2007-08-01
To perform a dynamic study of the relationship between Verisyse (AMO) and Artiflex (Ophtec B.V.) phakic intraocular lenses (pIOLs) and anterior chamber structures during accommodation using optical coherence tomography (OCT) (Visante, Carl Zeiss Meditec, Inc.) Institutional practice. Eleven myopic patients were randomly selected to have implantation of a Verisyse pIOL in 1 eye and an Artiflex pIOL in the other. Using a 2-dimensional image, dynamic measurements of the relationship between the anterior surface of the pIOL and the corneal endothelium, the posterior surface of the pIOL and the anterior surface of the crystalline lens, and the pupil diameter were performed using Visante OCT. Physiological accommodation was stimulated by adding lenses in 1.00 diopter (D) steps from +1.00 to -7.00 D. Both groups had a significant decrease in pupil diameter (P<.0001, generalized linear model [GLM]) and in the distance between the anterior surface of the pIOL and the corneal endothelium (P<.0001, GLM) with accommodation. There were no statistically significant changes in the distance between the posterior surface of either pIOL and the anterior surface of the crystalline lens (P = .2845, GLM). There were no statistically significant differences between the 2 pIOLs in any measurement (P>.05, GLM). The results fit with Helmholtz' theory of accommodation as forward movement of the diaphragm iris-crystalline lens was seen. There was a decrease in the distance between the pIOL and corneal endothelium and in the pupil diameter, whereas the distance between both pIOLs and the crystalline lens remained constant throughout the accommodation examination. This suggests that the risk for cataract from intermittent contact between the crystalline lens and IOL from accommodative effort is unlikely.
Inoue, Makoto; Noda, Toru; Ohnuma, Kazuhiko; Bissen-Miyajima, Hiroko; Hirakata, Akito
2011-11-01
To determine the quality of the image of a grating target placed in the vitreous of isolated pig eyes and photographed through implanted refractive and diffractive multifocal intraocular lenses (IOL). Refractive multifocal (NXG1, PY60MV), diffractive multifocal (ZM900, SA60D3) and monofocal (SA60AT, ZA9003) IOL were implanted in the capsular bag of isolated pig eyes. A grating target was placed in the vitreous and photographed through a flat or a wide-field viewing contact lens. The contrast of the grating targets of different spatial frequencies was measured. With the flat corneal contact lens, the gratings appeared clear and not distorted when viewed through the optics of the NXG1 and PY60MV for far vision but were distorted with reduced contrast when viewed through the optical zone for near vision. The images through the diffractive zone of the ZM900 and SA60D3 were more defocused than with the monofocal IOL (p < 0.005). Ghost images oriented centrifugally of the original image were seen with the ZM900 resulting in lower contrast at higher spatial frequencies than with the SA60D3 with less defocused images only in the central area. With the wide-field viewing contact lens, the images were less defocused and the contrast was comparable to both refractive and diffractive multifocal IOL. Both refractive and diffractive multifocal IOL reduced the contrast of the retinal image when viewed through a flat corneal contact lens but less defocused when viewed through a wide-field viewing contact lens. © 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.
Ophthalmic applications of confocal microscopy: diagnostics, refractive surgery, and eye banking
NASA Astrophysics Data System (ADS)
Masters, Barry R.
1990-11-01
Confocal microscopy of ocular tissue provides two advantages over traditional imaging techniques: increased range and transverse resolution and increased contrast. The semitransparent cornea and ocular lens in the living eye can be optically sectioned and observed by reflected light confocal microscopy. Within the cornea we observed various cell components nerve fibers nerve cell bodies and fibrous networks. The confocal microscopic images from the in-situ ocular lens show the lens capsule the lens epithelium and the individual lens fibrils. All of the reflected light confocal microscopic images have high contrast and high resolution. Some of the applications of confocal imaging in ophthalmology include: diagnostics of the cornea and the ocular lens examination prior to and after refractive surgery examination of intraocular lenses (IOL) and examination of eye bank material. Other ophthalmic uses of confocal imaging include: studies of wound healing therapeutics and the effects of contact lenses on the cornea. The proposed features of a clinical confocal microscope are reviewed. 2.
Alió, Jorge L; Plaza-Puche, Ana B; Piñero, David P
2012-04-01
To ascertain whether the refractive, visual, and intraocular optical quality outcomes of a rotationally asymmetric multifocal intraocular lens (IOL) are enhanced by the use of a capsular tension ring. Ninety consecutive eyes from 53 patients (age range: 36 to 82 years) were divided into two groups: the no ring group comprised 43 eyes implanted with the multifocal rotationally asymmetric Lentis Mplus LS-312 (Oculentis GmbH) without a capsular tension ring; and the ring group comprised 47 eyes with the same IOL with a capsular tension ring. Distance and near visual acuity and refractive outcomes were evaluated pre- and postoperatively. Contrast sensitivity, intraocular aberrations, and defocus curve were evaluated postoperatively. Significant postoperative differences between groups were found in sphere, spherical equivalent refraction, and near addition (P<.02). Regarding defocus curve, significantly better visual acuity was present in eyes with the capsular tension ring for intermediate vision conditions (P<.05). Intraocular aberrometry did not differ significantly between groups (P<.09). Refractive predictability and intermediate visual outcomes with the Lentis Mplus LS-312 IOL improved significantly when implanted in combination with a capsular tension ring. Copyright 2012, SLACK Incorporated.
Racial differences in ocular oxidative metabolism: implications for ocular disease.
Siegfried, Carla J; Shui, Ying-Bo; Holekamp, Nancy M; Bai, Fang; Beebe, David C
2011-07-01
To compare the Po(2) distribution in different regions in the eyes of patients undergoing intraocular surgery. Before initiation of intraocular cataract and/or glaucoma surgery, an optical oxygen sensor was introduced into the anterior chamber via a peripheral corneal paracentesis. The tip of the flexible fiberoptic probe was positioned by the surgeon for 3 measurements in all patients: (1) near the central corneal endothelium, (2) in the mid-anterior chamber, and (3) in the anterior chamber angle. In patients scheduled to undergo cataract extraction, Po(2) was also measured (4) at the anterior lens surface and (5) in the posterior chamber just behind the iris. Oxygen measurements at the 5 locations were compared using a 2-tailed unpaired t test and multivariate regression. The Po(2) value was significantly higher in African American patients at all 5 locations compared with Caucasian patients. Adjusting for age increased the significance of this association. Adjusting for race revealed that age was associated with increased Po(2) beneath the central cornea. Racial differences in oxygen levels in the human eye reflect an important difference in oxidative metabolism in the cornea and lens and may reflect differences in systemic physiologic function. Increased oxygen or oxygen metabolites may increase oxidative stress, cell damage, intraocular pressure, and the risk of developing glaucoma. Oxygen use by the cornea decreases with age.
Pigment dispersion glaucoma induced by the chafing effect of intraocular lens haptics in Asian eyes.
Hong, Ying; Sun, Yan-Xiu; Qi, Hong; Zhou, Ji-Chao; Hao, Yan-Sheng
2013-03-01
To study the possible mechanism and treatment for pigment dispersion glaucoma (PDG) caused by single-piece acrylic (SPA) intraocular lens (IOL) ciliary sulcus fixation in Asian eyes. Patients referred for PDG caused by SPA IOL ciliary sulcus fixation to our hospital from April 2005 to June 2011 were included. The patients' general information, IOL type, interval between initial surgery and PDG occurrence, examination findings, antiglaucoma medicine regimen and surgical interventions were recorded. In total, six eyes from five Chinese patients were included in this study. The intraocular pressure (IOP) increased 19-30 days after cataract surgery and was not satisfactorily controlled with antiglaucoma medication. Dense pigmentation was deposited on the IOLs and on the anterior chamber angle. IOL haptic chafing was noted on the rear iris surface. IOL repositioning in the capsular bag was performed in three eyes and was combined with trabeculectomy in two eyes with progressive glaucoma. An IOL exchange with three-piece IOL ciliary sulcus fixation was performed in the other three eyes. Scanning electron microscopy of the explanted IOLs demonstrated a rough edge on the IOL haptics. SPA IOLs were not suitable for ciliary sulcus fixation. The chafing effect of the IOL haptics on the posterior iris pigment epithelium could induce PDG in Asian eyes. IOLs should be positioned in the capsular bag or a three-piece IOL should be used instead.
Fouda, Sameh Mosaad; Al Aswad, Mahmoud A; Ibrahim, Basem M; Bori, Ashraf; Mattout, Hala K
2016-12-01
This study aimed to evaluate the safety and efficacy of retropupillary fixation of an iris-claw intraocular lens (IOL; Verisyse polymethyl methacrylate IOL, Abbott Medical Optics [AMO], Netherlands) for the surgical correction of aphakia in microspherophakic eyes without sufficient capsular support. This was a prospective, interventional, noncomparative case series. This interventional case series comprised 17 eyes of 9 microspherophakic patients. Retropupillary fixation of the Verisyse iris-claw IOL (AMO) was performed in all cases. The surgical time was measured. Corrected distance visual acuity, astigmatism, intraocular pressure (IOP), tissue reaction, pigment dispersion, and stability of the IOL were studied 1 day, 3 days, 1 week, 2 weeks, 1 month, and 6 months postoperatively. Eight patients had familial microspherophakia and one patient had Marfan's syndrome. Eighty-two percent of the cases achieved a visual acuity of 0.3 or better. There was no significant postoperative inflammatory reaction. Transient elevation of IOP was recorded in two cases in the 1st week only. One IOL developed disengagement of one of the haptics from the iris and was successfully re-engaged. All the other IOLs were well centered and stable. The mean surgical time was 18.0 ± 4.5 min. Retropupillary fixation of an iris-claw IOL is a safe and effective procedure that provides early visual recovery. It is also a time-saving method for correcting aphakia in microspherophakic eyes without sufficient capsular support.
Glue-assisted intrascleral fixation of posterior chamber intraocular lens
Narang, Priya; Narang, Samir
2013-01-01
Purpose: To analyze the visual outcome of patients undergoing glue-assisted intrascleral fixation of posterior chamber intraocular lens (IOL) in the absence of posterior capsular support. Materials and Methods: This retrospective study analyzes 25 eyes which underwent IOL implantation by the glued intrascleral fixation technique. The pre and post-operative uncorrected visual acuity (UCVA), pre and post-operative best corrected visual acuity (BCVA), intraocular pressure (IOP), IOL position, anterior chamber reaction and central macular thickness were assessed and recorded. Immediate and late post-operative complications were also recorded. Results: A total of 25 eyes of 22 patients were reviewed and analyzed over a period of one year. All eyes had a foldable three-piece IOL implanted. About 84% of the eyes had a gain of one or more lines, 12% had no gain, and 4% had a fall of three lines of BCVA on Snellen's visual chart, which was attributed to cystoid macular edema (CME). Postoperatively, there was a significant improvement in the UCVA (P < 0.05) and in the BCVA (P < 0.05). Postoperative complications included decentration in one case and vitritis with chronic macular edema in another case. Optical coherence tomography (OCT) demonstrated well placed IOL with no tilt. Conclusion: Although the results of one year follow-up of glued intrascleral fixation are promising, long term studies are recommended. PMID:23685487
Minami, Keiichiro; Maruyama, Yoko; Mihashi, Toshifumi; Miyata, Kazunori; Oshika, Tetsuro
2017-03-01
To evaluate the influence of increases in light scattering on intraocular lens (IOL) surfaces on paraxial forward scattering using goniophotometry and Hartmann-Shack wavefront aberrometry. Surface light scattering was reproduced experimentally by acceleratedly aging 4 intraocular lenses by 0, 3, 5, and 10 years each. Light scattering from both IOL surfaces was measured using Scheimpflug photography. The paraxial forward scattering from the aged IOLs was measured using a goniophotometer with a halogen light source (wavelength: 350-850 nm) and telecentric optics, and changes in the maximum intensity and full width at 10% of maximum intensity (FW10%) were evaluated. The influences on the retina image were examined using a Hartmann-Shack aberrometer (wavelength: 840 nm). The contrast and difference from the point spread function of the central centroids were evaluated. The mean surface light scattering from both IOL surfaces ranged from 30.0 to 118.3 computer compatible tape (CCT) and increased with each aging year. Evaluations using the goniophotometer and the Hartmann-Shack aberrometer showed no significant change in the paraxial forward scattering with the aging year (P > .45, Kruskal-Wallis test), and no association with the surface light scattering intensity was found (P > .75, Spearman rank correlation). This experimental study using aged IOLs demonstrated that surface light scattering does not influence paraxial forward scattering.
Temporal multiplexing with adaptive optics for simultaneous vision
Papadatou, Eleni; Del Águila-Carrasco, Antonio J.; Marín-Franch, Iván; López-Gil, Norberto
2016-01-01
We present and test a methodology for generating simultaneous vision with a deformable mirror that changed shape at 50 Hz between two vergences: 0 D (far vision) and −2.5 D (near vision). Different bifocal designs, including toric and combinations of spherical aberration, were simulated and assessed objectively. We found that typical corneal aberrations of a 60-year-old subject changes the shape of objective through-focus curves of a perfect bifocal lens. This methodology can be used to investigate subjective visual performance for different multifocal contact or intraocular lens designs. PMID:27867718
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-30
... radiation therapy (IORT), brachytherapy composite APC, multiple imaging composite APCs, cardiac... Outpatient Code Editor IOL Intraocular lens IOM Institute of Medicine IORT Intraoperative radiation treatment... Radiation Therapy (IORT) (APC 0412) a. Background b. CY 2013 Proposals for CPT Codes 77424, 77425, and 77469...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-27
... wheelchairs. Prosthetic devices are included in the definition of ``medical and other health services'' under section 1861(s)(8) of the Act. Prosthetic devices are defined in this section of the Act as ``devices... insertion of an intraocular lens.'' Other examples of prosthetic devices include cardiac pacemakers...
Sakamoto, Masashi; Hashimoto, Ryuya; Yoshida, Izumi; Maeno, Takatoshi
2018-01-01
We retrospectively reviewed patients with postoperative neovascular glaucoma (NVG) after vitrectomy for proliferative diabetic retinopathy to investigate how variables assessed before, during, and after vitrectomy are associated with the requirement for filtration surgery. The subjects in this retrospective, observational, comparative study were 55 consecutive patients (61 eyes) who underwent vitrectomy for proliferative diabetic retinopathy at Toho University Sakura Medical Center between December 2011 and November 2016, were followed up for at least 6 months after surgery, and developed NVG within 2 years after surgery. They comprised 44 men and 11 women of mean age 52.4±9.1 years, who were followed up for a mean 7.1±6.1 months. We collected data on the following 16 variables: sex, age, history of panretinal photocoagulation completed within 3 months before vitrectomy, presence/absence of a lens, obvious iris/angle neovascularization, tractional retinal detachment, diabetic macular edema, vitreous hemorrhage, visual acuity and intraocular pressure before vitrectomy and at the onset of NVG, glycated hemoglobin, fasting blood glucose, estimated glomerular filtration rate, and use of intraoperative gas tamponade. Logistic regression analysis with the backward elimination method identified preoperative fasting hyperglycemia ( P =0.08), high intraocular pressure at the onset of NVG ( P =0.04), and use of gas tamponade during vitrectomy ( P =0.008) to be significant risk factors for requirement of filtration surgery. Preoperative fasting hyperglycemia, high intraocular pressure at the onset of NVG, and use of gas tamponade during vitrectomy predispose patients to require filtration surgery in the event of postoperative NVG.
NASA Astrophysics Data System (ADS)
Geniusz, Malwina; ZajÄ c, Marek
2016-09-01
Intraocular lens (IOL) is an artificial lens implanted into the eye in order to restore correct vision after the removal of natural lens cloudy due to cataract. The IOL prolonged stay in the eyeball causes the creation of different changes on the surface and inside the implant mainly in form of small-size local defects such as vacuoles and calcium deposites. Their presence worsens the imaging properties of the eye mainly due to occurence of scattered light thus deteriorating the vision quality of patients after cataract surgery. It is very difficult to study influence the effects of these changes on image quality in real patients. To avoid these difficulties two other possibilities were chosen: the analysis of the image obtained in an optomechanical eye model with artificially aged IOL as well as numerical calculation of the image characteristics while the eye lens is burdened with adequately modeled defects. In experiments the optomechanical model of an eye consisting of a glass "cornea", chamber filled with liquid where the IOL under investigation was inserted and a high resulution CCC detector serving as a "retina" was used. The Modulation Transfer Function (MTF) of such "eye" was evaluated on the basis of image of an edge. Experiments show that there is significant connection between ageing defects and decrease in MTF parameters. Numerical part was performed with a computer programme for optical imaging analysis (OpticStudio Professional, Zemax Professional from Radiant Zemax, LLC). On the basis of Atchison eye model with lens burdened with defects Modulation Transfer Functio was calculated. Particular parameters of defects used in a numerical model were based on own measurements. Numerical simulation also show significant connection between ageing defects and decrease of MTF parameters. With this technique the influence of types, density and distribution of local defect in the IOL on the retinal image quality can be evaluated quickly without the need of performing very difficult and even dangereous experiments on real human patients.
de Freitas, Carolina; Ruggeri, Marco; Manns, Fabrice; Ho, Arthur; Parel, Jean-Marie
2013-01-15
We present a method for measuring the average group refractive index of the human crystalline lens in vivo using an optical coherence tomography (OCT) system which, allows full-length biometry of the eye. A series of OCT images of the eye including the anterior segment and retina were recorded during accommodation. Optical lengths of the anterior chamber, lens, and vitreous were measured dynamically along the central axis on the OCT images. The group refractive index of the crystalline lens along the central axis was determined using linear regression analysis of the intraocular optical length measurements. Measurements were acquired on three subjects of age 21, 24, and 35 years. The average group refractive index for the three subjects was, respectively, n=1.41, 1.43, and 1.39 at 835 nm.
Kim, Kwan Soo; Kim, Mo Sae; Kim, Joon Mo; Choi, Chul Young
2010-01-01
To evaluate the efficacy of Tracey wavefront aberrometry (Tracey Technologies, Houston, TX) and transmission electron microscopy for the detection of anterior lenticonus in Alport syndrome. Tracey wavefront aberrometry was used to treat a patient with bilateral anterior lenticonus who had a history of Alport syndrome. For transmission electron microscopic examination, anterior lens capsules were obtained during clear lens phacoemulsification and intraocular lens implantation. Spherical aberrations were the predominant higher-order aberrations in the internal optics of both eyes. The Tracey wavefront aberrometer showed that most of the irregular astigmatism originated from the lenticular portion. Transmission electron microscopy of the specimens showed anterior lens capsules with decreased thickness and multiple dehiscences. Tracey wavefront aberrometry and transmission electron microscopy are effective tools for evaluation of anterior lenticonus in Alport syndrome. Copyright 2010, SLACK Incorporated.
[Implantation of intraocular lenses in the ciliary sulcus].
Schulze, S; Bertelmann, T; Sekundo, W
2014-04-01
Implantation of an intraocular lens (IOL) into the ciliary sulcus is the second most common implantation site after the regular capsular bag (in the bag) placement of an IOL. Although mainly not primarily intended, it is very often used in both complicated cataract surgery and secondary implantation due to IOL dislocation or aphakia. In most cases stable positioning is possible, especially when using optic capture techniques. A variety of difficulties can occur with sulcus implantation depending on the anatomical and surgical conditions present at the time of implantation. The most anterior position of the sulcus lense has to be considered for calculation of the refractive power of the IOL.
[Scheimpflug photography for the examination of phakic intraocular lenses].
Baumeister, M
2014-10-01
High myopia phakic intraocular lenses (IOL) have become an established means of surgical correction for high ametropia. Scheimpflug photography is one of the methods which are frequently applied for postoperative examination of the implants. Results from published studies employing Scheimpflug photography for examination of anterior chamber angle-fixated, iris-fixated and sulcus-fixated phakic IOLs were evaluated. In several published studies Scheimpflug photography was used to examine the position of the implant and opacification of the crystalline lens. The results provided valuable evidence for the improvement of phakic IOL design. Scheimpflug photography offers an easy to use, rapid non-contact examination of phakic IOLs.
Simple technique to measure toric intraocular lens alignment and stability using a smartphone.
Teichman, Joshua C; Baig, Kashif; Ahmed, Iqbal Ike K
2014-12-01
Toric intraocular lenses (IOLs) are commonly implanted to correct corneal astigmatism at the time of cataract surgery. Their use requires preoperative calculation of the axis of implantation and postoperative measurement to determine whether the IOL has been implanted with the proper orientation. Moreover, toric IOL alignment stability over time is important for the patient and for the longitudinal evaluation of toric IOLs. We present a simple, inexpensive, and precise method to measure the toric IOL axis using a camera-enabled cellular phone (iPhone 5S) and computer software (ImageJ). Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Solid intraocular xanthogranuloma in three Miniature Schnauzer dogs.
Zarfoss, Mitzi K; Dubielzig, Richard R
2007-01-01
Macrophages that contain abundant intracytoplasmic lipid are called 'foam cells'. In four canine globes submitted to the Comparative Ocular Pathology Laboratory of Wisconsin (COPLOW), foam cells formed a solid intraocular mass. The purpose of this study was to describe the histopathologic findings in these cases. The electronic COPLOW database (1993-2006) was searched for the diagnosis of 'foam cell tumor'. Clinical history, gross pathology and histopathology (5-micron sections, hematoxylin and eosin and Alcian blue periodic acid Schiff) were reviewed in all cases. Cases were included if the globe was grossly filled by a solid mass and if all intraocular structures were effaced by lipid-laden foam cell macrophages admixed with birefringent, Alcian blue-positive crystals oriented in stellate patterns. All three patients (four globes) satisfying the selection criteria were Miniature Schnauzers. In all cases the clinical history included diabetes mellitus, hyperlipidemia and chronic bilateral uveitis that was interpreted to be lens-induced. All globes were enucleated because of glaucoma. The term solid intraocular xanthogranuloma was used to describe these cases because the intraocular contents were effaced by a solid mass of foam cells and birefringent crystals. The cases in this report suggest that diabetic Miniature Schnauzers with hyperlipidemia are at risk for lipid and macrophage-rich uveitis, which may in some cases form a solid inflammatory intraocular mass, precipitate glaucoma, and lead to enucleation.
Gupta, Shikha; Sagar, Pradeep; Gogia, Varun; Khokhar, Sudarshan; Dada, Tanuj
2016-03-01
A young patient presented with visual acuity of hand movements only, unrecordable intraocular pressure, and total cataract after trauma 12 months ago. She reported failure to improve with conservative therapy as well as a direct cycloplexy elsewhere. After cleft localization on preoperative gonioscopy, ultrasound biomicroscopy (UBM), and intraoperative gonioscopy, a partial-thickness scleral flap was fashioned at the site of maximum cleft height. Following phacoaspiration, a multipiece intraocular lens was implanted in the sulcus; its haptics aligned to the axis with maximum height of cyclodialysis. A Cionni ring placed in sulcus was sutured to sclera under the flap to provide additional tamponading effect. Postoperative UBM and gonioscopy confirmed cleft closure. Normalization of intraocular pressure was found on repeated follow-ups till 1 year (12 to 14 mm Hg). UBM showed increase in sulcus diameter, and "double indentation sign" on the ciliary body.
Managing residual refractive error after cataract surgery.
Sáles, Christopher S; Manche, Edward E
2015-06-01
We present a review of keratorefractive and intraocular approaches to managing residual astigmatic and spherical refractive error after cataract surgery, including laser in situ keratomileusis (LASIK), photorefractive keratectomy (PRK), arcuate keratotomy, intraocular lens (IOL) exchange, piggyback IOLs, and light-adjustable IOLs. Currently available literature suggests that laser vision correction, whether LASIK or PRK, yields more effective and predictable outcomes than intraocular surgery. Piggyback IOLs with a rounded-edge profile implanted in the sulcus may be superior to IOL exchange, but both options present potential risks that likely outweigh the refractive benefits except in cases with large residual spherical errors. The light-adjustable IOL may provide an ideal treatment to pseudophakic ametropia by obviating the need for secondary invasive procedures after cataract surgery, but it is not widely available nor has it been sufficiently studied. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Lee, F N; Kong, V Y; Lee, G P; Ho, K H; Choon, S C; Hoh, H B
1999-12-01
A total of 114 patients (48 Chinese, 34 Malay and 32 Indian) undergoing extracapsular cataract extraction (ECCE) with intraocular lens implantation, were enrolled. All were given 3 ml of local anaesthetic (combination of equal amounts of lignocaine 2% and bupivacaine 0.5%) using retrobulbar technique. Intraocular pressure (IOP) was measured at different time intervals; before, immediately after and 5 minutes after injection with Honan balloon compression. Mean IOP increased by 5.0 mmHg immediately after injection (p < 0.001) and reduced to baseline level after 5 minutes of external compression. Although there were no statistical difference in terms of IOP variation between sex and age groups, Chinese patients demonstrated the highest IOP rise following retrobulbar anaesthesia. This is the first study to demonstrate the influence of race in the IOP response with Chinese subjects having the highest IOP rise.
da Costa, Marcelo Fernandes; Júnior, Augusto Paranhos; Lottenberg, Claudio Luiz; Castro, Leonardo Cunha; Ventura, Dora Fix
2017-12-01
The purpose of this study was to measure luminance contrast sensitivity and color vision thresholdfs in normal subjects using a blue light filter lens and transparent intraocular lens material. Monocular luminance grating contrast sensitivity was measured with Psycho for Windows (version 2.36; Cambridge Research Systems) at 3.0, 6.0, 12.0, 20.0, and 30.0 cycles per degree of visual angle (cpd) in 15 normal subjects (eight female), with a mean age of 21.6 years (SD = 3.8 years). Chromatic discrimination was assessed with the Cambridge colour test (CCT) along the protan, deutan, and tritan color confusion axes. Both tests were performed in a darkened room under two situations: with a transparent lens and with blue light filter lens. Subjective impressions were taken by subjects regarding their visual experience under both conditions. No difference was found between the luminance contrast sensitivity measured with transparent and blue light filter. However, 13/15 (87%) of the subjects reported more comfortable vision with the blue filter. In the color vision test, tritan thresholds were significantly higher for the blue filter compared with the transparent filter (p = 0.003). For protan and deutan thresholds no differences were found. Blue-yellow color vision is impaired with the blue light filter, and no impairment occurs with the transparent filter. No significant differences in thresholds were found in the luminance contrast sensitivity comparing the blue light and transparent filters. The impact of short wavelength light filtering on intrinsically photosensitive retinal ganglion cells is also discussed.
Ramji, Hasnain; Moore, Johnny; Moore, C B Tara; Shah, Sunil
2016-04-01
To optimise intraocular lens (IOL) power calculation techniques for a segmental multifocal IOL, LENTIS™ MPlus(®) (Oculentis GmbH, Berlin, Germany) and assess outcomes. A retrospective consecutive non-randomised case series of patients receiving the MPlus(®) IOL following cataract surgery or clear lens extraction was performed at a privately owned ophthalmic hospital, Midland Eye, Solihull, UK. Analysis was undertaken of 116 eyes, with uncomplicated lens replacement surgery using the LENTIS™ MPlus(®) lenses. Pre-operative biometry data were stratified into short (<22.00 mm) and long axial lengths (ALs) (≥22.00 mm). IOL power predictions were calculated with SRK/T, Holladay I, Hoffer Q, Holladay II and Haigis formulae and compared to the final manifest refraction. These were compared with the OKULIX ray tracing method and the stratification technique suggested by the Royal College of Ophthalmologists (RCOphth). Using SRK/T for long eyes and Hoffer Q for short eyes, 64% achieved postoperative subjective refractions of ≤±0.25 D, 83%≤±0.50 D and 93%≤±0.75 D, with a maximum predictive error of 1.25D. No specific calculation method performed best across all ALs; however for ALs under 22 mm Hoffer Q and Holliday I methods performed best. Excellent but equivalent overall refractive results were found between all biometry methods used in this multifocal IOL study. For eyes with ALs under 22 mm Hoffer Q and Holliday I performed best. Current techniques mean that patients are still likely to need top up glasses for certain situations. Copyright © 2015 Elsevier Ltd. All rights reserved.
Ferrer-Blasco, Teresa; Domínguez-Vicent, Alberto; García-Lázaro, Santiago; Diez, María Amparo; Alfonso, José F; Esteve-Taboada, José J
2018-06-01
To assess the in vitro optical quality of monofocal aspheric toric intraocular lenses (IOLs) as a function of the cylindrical power. The in vitro optical quality of the AcrySof IQ Toric IOLs SN6AT2, SN6AT3, SN6AT4, SN6AT5 and SN6AT6 (Alcon Laboratories Inc., Forth Worth, TX, USA) was assessed with an instrument conceived for measuring Zernike's coefficients at 3.0- and 5.0-mm apertures. As a reference, the aspheric monofocal lens AcrySof IQ Aspheric SN60WF (Alcon Laboratories Inc., Forth Worth, TX, USA) was also measured. The area of visibility and cut-off frequency were used to describe the modulation transfer function (MTF) of each lens; meanwhile, the light in the bucket and the diameter of a circular area centred on the point-spread function (PSF) peak that captures 50% of the light energy were used to describe the PSF of each lens. Finally, an image simulation was computed from the Zernike values with reference purposes. Small differences were found on the metrics used for describing the MTF and PSF of the lenses at both tested apertures, but these were not statistically significant (p > 0.05). Furthermore, the image simulation showed that these differences would not have clinical relevance at all. The optical performance of the AcrySof IQ toric IOLs in terms of MTF and PSF is good and seems to be independent of the cylindrical power and similar to a non-toric aspheric lens.
Masis Solano, Marisse; Lin, Shan C
2018-01-29
Cataract extraction is a safe and effective surgery that has a lowering effect on the intraocular pressure. The specific mechanisms for this effect are still unclear. A direct inflammatory effect on the trabecular meshwork, alteration of the blood aqueous barrier, changes in the ciliary body and mechanical changes of the anterior segment anatomy are the key to understand cataract surgery and it's effects on aqueous humor dynamics. Additionally, with the advent of AS OCT, changes in the anterior segment of the eye have been studied and several parameters (such as lens vault, angle opening distance and anterior chamber depth) have been identified as predictors of intraocular pressure change. In eyes with narrow angles there is a greater drop in intraocular pressure after cataract surgery and it is correlated with parameters related to anterior chamber space. It is safe to affirm that cataract surgery is an important part of the modern glaucoma treatment and evidence should be analyzed as part of a bigger picture in order to more accurately understand its clinical relevance. Copyright © 2018. Published by Elsevier Ltd.
Khoramnia, Ramin; Auffarth, Gerd U; Rabsilber, Tanja M; Holzer, Mike P
2012-11-01
We report a 66-year-old patient who presented with increasing hyperopia, astigmatism, and presbyopia in both eyes 8 years after bilateral laser in situ keratomileusis (LASIK) and LASIK enhancement in the left eye aiming for spectacle independence. Bilateral multifocal toric Lentis Mplus intraocular lenses (IOLs) with an embedded near segment and individually customized cylinder correction were implanted uneventfully following phacoemulsification. The Haigis-L formula after previous hyperopia correction was chosen for IOL power calculation and provided reliable results. Emmetropia was targeted and achieved. Three months postoperatively, the uncorrected distance visual acuity had increased from 0.40 logMAR to 0.10 logMAR in the right eye and from 0.20 logMAR to 0.00 logMAR in the left eye. The patient gained 6 lines of uncorrected near visual acuity: 0.20 logMAR in the right eye and 0.10 logMAR in the left eye. This case shows that customized premium IOL implantation can provide accurate results even in challenging cases. The International Vision Correction Research Centre, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany, has received research grants, lecture fees, and travel reimbursement from Oculentis GmbH. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Liu, Xing; Li, Mei; Cheng, Bing; Mao, Zhen; Zhong, Yimin; Wang, Dandan; Cao, Dan; Yu, Fenfen; Congdon, Nathan G
2013-11-01
To describe sequential phacoemulsification-intraocular lens (IOL) implantation-posterior capsulorhexis-anterior vitrectomy in the management of phakic malignant glaucoma. Twenty consecutive patients (25 eyes) with phakic malignant glaucoma were enrolled at the Zhongshan Ophthalmic Center, Sun Yat-sen University. All patients underwent phacoemulsification, IOL implantation and posterior capsulorhexis together with anterior vitrectomy via a clear corneal paracentesis. Visual acuity, intraocular pressure (IOP), anterior chamber depth (ACD), surgical complications and medications required after the surgery were recorded. After surgery, the mean LogMAR visual acuity and ACD increased significantly (visual acuity from -1.56 ± 1.17 to -0.54 ± 0.81, p < 0.001; ACD from 0.367 ± 0.397 mm to 2.390 ± 0.575 mm, p < 0.001), and mean IOP decreased significantly (from 39.6 ± 10.6 mm Hg to 14.5 ± 4.1 mmHg, p < 0.001). No serious perioperative complications occurred, and only five eyes required topical glaucoma medications after surgery. Combined phacoemulsification-IOL implantation-posterior capsulorhexis-anterior vitrectomy surgery is a safe and effective method for treating patients with phakic malignant glaucoma. © 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-04
....Prosthetic devices are included in the definition of ``medical and other health services'' under section 1861(s)(8) of the Act. Prosthetic devices are defined in this section of the Act as ``devices (other than... intraocular lens.'' Other examples of prosthetic devices include cardiac pacemakers, cochlear implants...
[Clinical results after implantation of a new segmental refractive multifocal intraocular lens].
Thomas, B C; Auffarth, G U; Philips, R; Novák, J; Blazek, J; Adamkova, H; Rabsilber, T M
2013-11-01
The aim of the study was a clinical evaluation of an intraocular lens (IOL) with a segmental multifocal optic design and near addition of + 3.0 D as part of a CE approval study. In a multicenter study the LENTIS Mplus LS-312 MF IOL (Oculentis) was implanted in 134 eyes of 79 patients with a mean age of 68 ± 12 years. The multifocality is achieved by implementation of a distance part and a segmented near sector. Three months after surgery, uncorrected and best corrected distance visual acuity (UCDVA and BCDVA, respectively), near visual acuity (UCNVA and BCNVA, respectively), contrast vision and patient satisfaction (questionnaire) were evaluated. The IOLs were implanted uneventfully either unilaterally or bilaterally and 3 months postoperatively (n = 86 eyes) the following mean visual acuities were obtained (logMAR): UCDVA = 0.05, BCDVA = - 0.01, UCNVA = 0.09 and BCNVA = 0.02. Contrast sensitivity (n = 25 eyes) was within normal limits. Of the 66 questioned patients 10.6% spontaneously reported halos and 3% glare. This new innovative multifocal IOL concept showed very good functional results as well as high patient satisfaction.
Temporal multiplexing to simulate multifocal intraocular lenses: theoretical considerations
Akondi, Vyas; Dorronsoro, Carlos; Gambra, Enrique; Marcos, Susana
2017-01-01
Fast tunable lenses allow an effective design of a portable simultaneous vision simulator (SimVis) of multifocal corrections. A novel method of evaluating the temporal profile of a tunable lens in simulating different multifocal intraocular lenses (M-IOLs) is presented. The proposed method involves the characteristic fitting of the through-focus (TF) optical quality of the multifocal component of a given M-IOL to a linear combination of TF optical quality of monofocal lenses viable with a tunable lens. Three different types of M-IOL designs are tested, namely: segmented refractive, diffractive and refractive extended depth of focus. The metric used for the optical evaluation of the temporal profile is the visual Strehl (VS) ratio. It is shown that the time profiles generated with the VS ratio as a metric in SimVis resulted in TF VS ratio and TF simulated images that closely matched the TF VS ratio and TF simulated images predicted with the M-IOL. The effects of temporal sampling, varying pupil size, monochromatic aberrations, longitudinal chromatic aberrations and temporal dynamics on SimVis are discussed. PMID:28717577
Zafar, Andleeb; Aslanides, Ioannis M.; Selimis, Vasileios; Tsoulnaras, Konstantinos I.; Tabibian, David; Kymionis, George D.
2018-01-01
Purpose We report here the case of a patient with anterior segment migration of intravitreal dexamethasone implant as well as its management and outcome. Methods The patient had the following sequence of events: complicated cataract surgery, iris-sutured intraocular lens implant, followed by cystoid macular edema treated with intravitreal Avastin, retinal vein occlusion treated with intravitreal dexamethasone implant, corneal decompensation treated with Descemet stripping automated endothelial keratoplasty (DSAEK), and finally recurrence of macular edema treated with repeated intravitreal dexamethasone implant. Results Dexamethasone implant had completely dissolved from the eye 12 weeks after insertion without any complication. Conclusion A conservative approach with regular monitoring in the situation of a quiet anterior segment without any corneal decompensation can provide enough time for the implant to dissolve without causing any complication to the involved eye, avoiding any additional surgical intervention, as presented in this case report. Despite the fact that the implant was left for natural dissolution, there were no adverse effects related to the graft or the eye. PMID:29643797
Injectable suture device for intraocular lens fixation.
Smith, Jesse M; Erlanger, Michael; Olson, Jeffrey L
2015-12-01
We describe a surgical technique for scleral fixation of a posterior chamber intraocular lens (PC IOL) using a 24-gauge injectable polypropylene suture delivery system. A 3-piece PC IOL is inserted into the anterior chamber of the eye. Two sclerotomies are made 1.5 mm posterior to the limbus using a microvitreoretinal blade. The 24-gauge injector delivers a preformed suture loop into the eye with the double-armed needles still external to the eye. Each polypropylene IOL haptic is directed through the loop using microforceps. The suture loop is tightened around the haptic, and the attached needles are used to fixate the IOL to the sclera and close the sclerotomies simultaneously. This technique has been used in an ex vivo porcine eye and in an aphakic patient. In the latter, the IOL was quickly fixated to the sclera and maintained a stable position postoperatively. Dr. Olson has a patent pending for the device described in this article. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Rehabilitation of children with cataracts.
Hiatt, R L
1998-01-01
Over a period of 10 years, 160 children with cataracts underwent operation at the University of Tennessee Medical Center, Memphis. The surgical, optical, and psychosocial rehabilitation of these patients was analyzed and studied. The optical rehabilitation included patients with glasses, intraocular lens implants, epikeratophakia, and contact lenses. Seventy three of these patients were chosen at random and reevaluated as to visual outcome, and 46 were subjected to a psychosocial test to evaluate their quality of life and their rehabilitation. Eighteen of these were also given a psychosocial test to evaluate the quality of life enjoyed by these children at an older age following treatment for the cataract. Surgical, optical, and psychosocial rehabilitation of such children is also discussed. This is the first report of the psychological evaluation of such children. The further needs of these children as they approach adulthood are discussed in detail. PMID:10360302
Tortolano, Lionel; Serrano, Carole; Jubeli, Emile; Saunier, Johanna; Yagoubi, Najet
2015-12-01
The aim of this study is to investigate in vitro interactions between hydrophobic acrylate intraocular lenses (IOLs) and their biological environment. The influence of lens chemical composition and aging on fibronectin (FN) adsorption and on IOLs cytotoxicity on human lens epithelial cells was examined. Cytotoxicity of acrylate monomers used in IOLs manufacture was also investigated. Four different IOLs were included in the study: Acrysof(®), Tecnis(®), EnVista(®), and iSert(®). Implants were artificially aged in a xenon arc chamber to simulate 2 years of light exposure. Fibronectin adsorption on IOL surface was quantified using ELISA and correlated to surface roughness determined with AFM. Direct contact cytotoxicity was determined with the MTT assay and cell morphology was observed with light microscopy. Results showed that fibronectin adsorption did not differ significantly among IOLs, whatever their chemical composition. Moreover, aging conditions did not impact fibronectin adsorption. All IOLs were biocompatible even after applying 2-year aging conditions, with cell viability higher than 70%. Five acrylate monomers appeared to be toxic in the range of concentrations tested, but no monomer release from the IOLs could be detected during accelerated 2-year incubation with saline solution. This study did not reveal an influence of chemical composition and aging on protein adsorption and on biocompatibility. © 2015 Wiley Periodicals, Inc.
Foldable iris-fixated intraocular lens implantation in children.
Ryan, Andrea; Hartnett, Claire; Lanigan, Bernadette; O'Keefe, Michael
2012-09-01
To describe the results of foldable iris-fixated intraocular lens (IOL) implantation in children. Children with high bilateral or unilateral myopia who were intolerant of spectacle or contact lens correction were implanted with an iris-fixated foldable IOL and prospectively followed. We measured pre- and postoperative visual acuity, refraction, endothelial cell density (ECD) and National Eye Institute Visual Functioning Questionnaire-25. Eleven eyes of six children were implanted. Indications were high bilateral myopia in children with comorbid neurobehavioural disorders, high anisometropia and high myopic astigmatism. Mean preoperative spherical equivalent (SE) refraction was -14.6 dioptres (D)±4.2 SD. Mean follow-up was 15 months. Postoperative SE refraction was -2.40 D±2.40 SD. Corrected distance visual acuity (CDVA) improved from mean logMAR 0.84±0.4 SD to postoperative 0.67±0.34 SD (p=0.005). CDVA was reduced because of coexistent ocular disorders and amblyopia. Vision-related quality of life (QOL) measures improved significantly. There were no intraoperative or postoperative serious complications. Foldable iris-fixated IOL insertion can give a significant improvement in vision and in vision-related QOL in a subset of paediatric patients with special refractive needs who are intolerant to conventional treatment. Long-term follow-up is required for monitoring of ECD. © 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.
Hayashi, K.; Hayashi, H.; Nakao, F.; Hayashi, F.
2001-01-01
AIM—To prospectively investigate changes in the area of the anterior capsule opening, and intraocular lens (IOL) decentration and tilt after implantation of a hydrogel IOL. METHODS—100 patients underwent implantation of a hydrogel IOL in one eye and an acrylic IOL implantation in the opposite eye. The area of the anterior capsule opening, and the degree of IOL decentration and tilt were measured using the Scheimpflug videophotography system at 3 days, and at 1, 3, and 6 months postoperatively. RESULTS—The mean anterior capsule opening area decreased significantly in both groups. At 6 months postoperatively, the area in the hydrogel group was significantly smaller than that in the acrylic group. The mean percentage of the area reduction in the hydrogel group was also significantly greater than that in the acrylic group, being 16.9% in the hydrogel group and 8.8% in the acrylic group. In contrast, IOL decentration and tilt did not progress in either group. No significant differences were found in the degree of IOL decentration and tilt throughout the follow up period. CONCLUSIONS—Contraction of the anterior capsule opening was more extensive with the hydrogel IOL than with the acrylic IOL, but the degree of IOL decentration and tilt were similar for the two types of lenses studied. PMID:11673291
AlSabaani, Nasser A.; Behrens, Ashley; Jastanieah, Sabah; Al Malki, Salem; Al Jindan, Mohanna; Al Motowa, Saeed
2016-01-01
PURPOSE: The purpose of this study is to evaluate the causes of phakic implantable collamer lens (ICL) explantation/exchange at an eye hospital in Saudi Arabia. MATERIALS AND METHODS: A retrospective chart review was performed for patients who underwent ICL implantation from 2007 to March 2014 and data were collected on cases that underwent ICL explantation. RESULTS: Of the 787 ICL implants, 30 implants (3.8% [95% confidence interval 2.6%; 5.3%]) were explanted. The causes of explantation included incorrect lens size (22), cataract (4), high residual astigmatism (2), rhegmatogenous retinal detachment (1), and intolerable glare (1). Corrective measures mainly included an exchange with an appropriately sized lens (9), ICL explantation (11), with phacoemulsification and posterior chamber intraocular lens implantation (6), or replacement with an ICL of correct power (2). CONCLUSION: Incorrect ICL size was the most common cause of ICL explantation. More accurate sizing methods for ICL are required to reduce the explantation/exchange rate. PMID:27994391
Accidental injections of dexamethasone intravitreal implant (Ozurdex) into the crystalline lens.
Coca-Robinot, Javier; Casco-Silva, Bruno; Armadá-Maresca, Felix; García-Martínez, Jesús
2014-01-01
To describe the side effects and management after inadvertent injection of a dexamethasone implant (Ozurdex) into the crystalline lens. Two case reports. Two patients with macular edema due to unilateral retinal vein occlusion were scheduled for an intravitreal injection of Ozurdex. During the procedure, the implant was accidentally injected into the crystalline lens. Both patients developed cataracts during the course of several weeks and in both there was an intraocular pressure (IOP) increase, which required treatment with topical hypotensives. Macular edema improved only slightly. Cataract surgery with uneventful removal of the implant was performed 3 (case 1) and 6 months (case 2) after the injection. After inadvertent injection of Ozurdex into the crystalline lens, cataract surgery with removal of the implant should be performed as soon as possible in order to avoid IOP increase and so that the underlying condition may be treated adequately.
Lenticular neovascularization subsequent to traumatic cataract formation.
Kabat, Alan G
2011-09-01
To report a series of cases involving neovascularization within the human crystalline lens-a normally avascular structure-after ocular trauma. This is a retrospective, consecutive observational case series with review of the prevailing literature. Four individuals with a history of ocular trauma and subsequent cataract development were examined between May 2004 and April 2007. All had hypermature cataracts and intraocular inflammation, presumably secondary to phacolysis; two of the four had concurrent hyphema and ocular hypertension in the involved eye. All subjects in this series were found to display a discrete network of blood vessels within the structure of the crystalline lens, just beneath the anterior lens capsule. Neovascularization of the crystalline lens has received little attention in the ophthalmic literature, having been described only rarely in individual case reports. This manuscript details the first known case series involving lenticular neovascularization, and offers insight into its possible developmental mechanism.
Alió, Jorge L; Plaza-Puche, Ana B; Javaloy, Jaime; Ayala, María José; Vega-Estrada, Alfredo
2013-04-01
To compare the visual and intraocular optical quality outcomes with different designs of the refractive rotationally asymmetric multifocal intraocular lens (MFIOL) (Lentis Mplus; Oculentis GmbH, Berlin, Germany) with or without capsular tension ring (CTR) implantation. One hundred thirty-five consecutive eyes of 78 patients with cataract (ages 36 to 82 years) were divided into three groups: 43 eyes implanted with the C-Loop haptic design without CTR (C-Loop haptic only group); 47 eyes implanted with the C-Loop haptic design with CTR (C-Loop haptic with CTR group); and 45 eyes implanted with the plate-haptic design (plate-haptic group). Visual acuity, contrast sensitivity, defocus curve, and ocular and intraocular optical quality were evaluated at 3 months postoperatively. Significant differences in the postoperative sphere were found (P = .01), with a more myopic postoperative refraction for the C-Loop haptic only group. No significant differences were detected in photopic and scotopic contrast sensitivity among groups (P ⩾ .05). Significantly better visual acuities were present in the C-Loop haptic with CTR group for the defocus levels of -2.0, -1.5, -1.0, and -0.50 D (P ⩽.03). Statistically significant differences among groups were found in total intraocular root mean square (RMS), high-order intraocular RMS, and intraocular coma-like RMS aberrations (P ⩽.04), with lower values from the plate-haptic group. The plate-haptic design and the C-Loop haptic design with CTR implantation both allow good visual rehabilitation. However, better refractive predictability and intraocular optical quality was obtained with the plate-haptic design without CTR implantation. The plate-haptic design seems to be a better design to support rotational asymmetric MFIOL optics. Copyright 2013, SLACK Incorporated.
Electron microscopic examination of the anterior lens capsule in a case of Alport's syndrome.
Citirik, Mehmet; Batman, Cosar; Men, Gamze; Tuncel, Murvet; Zilelioglu, Orhan
2007-09-01
To report a case of Alport's syndrome and to present electronmicroscopic examination findings of the anterior lens capsule of this patient. A 21-year-old man was referred for low visual acuity and retinal pigment epithelial changes in the left eye. The patient and his relatives underwent detailed ophthalmological examination, including electrophysiological testing. The patient also underwent electronmicroscopic examination of the anterior lens capsule. His visual acuity was 6/18 OD and 6/15 OS. Anterior lenticonus and subcapsular opacities were observed in the left eye. Cataract extraction by phacoemulsification with intraocular lens implantation was performed for his poor visual performance. During the capsulorhexis, the remarkably thin and fragile anterior capsule was noted and removed. Ultrastructural analysis of the anterior lens capsule showed a thinner central zone compared with the periphery. The course of Alport's syndrome can be ameliorated by early diagnosis. Therefore, the ophthalmological examination of a patient with anterior lenticonus must be combined with a detailed medical evaluation. Ultrastructural analysis of the lens capsule can support the diagnosis of Alport's syndrome.
Uveitis-glaucoma-hyphema syndrome associated with recurrent vitreous hemorrhage.
Alfaro-Juárez, A; Vital-Berral, C; Sánchez-Vicente, J L; Alfaro-Juárez, A; Muñoz-Morales, A
2015-08-01
A 61-year-old pseudophakic male with recurrent blurred vision episodes associated with uveitis, hyphema, glaucoma and vitreous hemorrhage. Iris transillumination defects and apposition of the optic and iris were found. The patient was diagnosed with Uveitis-Glaucoma-Hyphema (UGH) Syndrome. Mechanical irritation of the iris is a consequence of intraocular lens malposition and causes UGH Syndrome. Occasionally it is associated with vitreous hemorrhage. Lens malposition is detected by optical coherence tomography and/or ultrasound biomicroscopy. Copyright © 2014 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.
Hayashi, K.; Hayashi, H.; Nakao, F.; Hayashi, F.
1998-01-01
BACKGROUND—The extent of the decentration and tilt was prospectively compared between one piece polymethyl methacrylate (PMMA) and three piece PMMA intraocular lenses (IOLs) which were implanted in the capsular bag after performing continuous curvilinear capsulorhexis. METHODS—91 patients underwent a one piece PMMA IOL implantation in one eye as well as the implantation of the three piece PMMA IOL with polyvinylidene fluoride loops in the opposite eye. The length of the lens decentration and the angle of the tilt were quantitated using the anterior eye segment analysis system (EAS-1000) at 1 week as well as 1, 3, and 6 months postoperatively. RESULTS—The mean length of the decentration in the one piece IOL was smaller than that in the three piece IOL at 1 week (p=0.0092), 1 month (p=0.0044), 3 months (p=0.0069), and 6 months (p=0.0010) postoperatively. However, no significant difference was found in the degree of the tilt between the two types of IOLs throughout the observation periods. CONCLUSION—These results clarified that the one piece PMMA IOL with rigid PMMA haptics implanted in the capsular bag provides a better centration than the three piece PMMA IOL with flexible haptics, whereas the tilt was the same between the two types of IOLs. Keywords: intraocular lens; decentration; tilt; continuous curvilinear capsulorhexis PMID:9640193
Asano, Sayaka; Miyake, Kensaku; Ota, Ichiro; Sugita, Gentaro; Kimura, Wataru; Sakka, Yuji; Yabe, Nobuyuki
2008-01-01
To compare the effectiveness of a topical nonsteroidal drug (diclofenac 0.1%) and a topical steroidal drug (betamethasone 0.1%) in preventing cystoid macular edema (CME) and blood-aqueous barrier (BAB) disruption after small-incision cataract surgery and foldable intraocular lens (IOL) implantation. Shohzankai Medical Foundation Miyake Eye Hospital, Tokyo, Japan. This multicenter interventional double-masked randomized study comprised 142 patients having phacoemulsification and foldable IOL implantation. Seventy-one patients were randomized to receive diclofenac eyedrops and 71, betamethasone eyedrops for 8 weeks postoperatively. The incidence and severity of CME were evaluated by fluorescein angiography. Blood-aqueous barrier disruption was determined by laser flare-cell photometry. Of the patients, 63 were men and 79 were women. Five weeks after surgery, the incidence of fluorescein angiographic CME was lower in the diclofenac group (18.8%) than in the betamethasone group (58.0%) (P<.001). At 1 and 2 weeks, the amount of anterior chamber flare was statistically significantly less in the diclofenac group than in the betamethasone group (P<.05). At 8 weeks, intraocular pressure was statistically significantly higher in the betamethasone group (P = .0003). Diclofenac was more effective than betamethasone in preventing angiographic CME and BAB disruption after small-incision cataract surgery. Thus, nonsteroidal antiinflammatory agents should be considered for routine treatment of eyes having cataract surgery.
Weiner, Asher; Cohn, Aaron D; Balasubramaniam, Mamtha; Weiner, Adam J
2010-08-01
To summarize our clinical experience with implanting Baerveldt glaucoma tube shunts through the ciliary sulcus in eyes with a posterior chamber intraocular lens and shallow anterior chambers, corneal transplants, guttata or edema. A retrospective interventional nonrandomized noncomparative case series. Main outcome measure was postoperative corneal status. Secondary outcome measures included postoperative intraocular pressure (IOP), visual acuity and complications. Thirty-six eyes of 32 patients were identified through chart review. Follow-up period was 21.8+/-16.6 months (mean+/-standard deviation, range: 4.0 to 58.5 mo). At final visit, all 23 preoperative clear native corneas and 6 of 7 corneal transplants remained clear. Thus, of the 30 preoperative clear corneas, only 1 decompensated. Preoperative IOP was 27.9+/-11.8 mm Hg (range: 12 to 59 mm Hg), reduced postoperatively to 10.1+/-3.9 mm Hg (range: 2 to 21 mm Hg, P=0.0001), a reduction of 58.2%+/-19.3% (range: 5.0% to 95.4%). Final IOP was >or=5 and
Kirgiz, Ahmet; Atalay, Kurşat; Kaldirim, Havva; Cabuk, Kubra Serefoglu; Akdemir, Mehmet Orcun; Taskapili, Muhittin
2017-08-01
The purpose of this study was to compare the keratometry (K) values obtained by the Scheimpflug camera combined with placido-disk corneal topography (Sirius) and optical biometry (Lenstar) for intraocular lens (IOL) power calculation before the cataract surgery, and to evaluate the accuracy of postoperative refraction. 50 eyes of 40 patients were scheduled to have phacoemulsification with the implantation of a posterior chamber intraocular lens. The IOL power was calculated using the SRK/T formula with Lenstar K and K readings from Sirius. Simulated K (SimK), K at 3-, 5-, and 7-mm zones from Sirius were compared with Lenstar K readings. The accuracy of these parameters was determined by calculating the mean absolute error (MAE). The mean Lenstar K value was 44.05 diopters (D) ±1.93 (SD) and SimK, K at 3-, 5-, and 7-mm zones were 43.85 ± 1.91, 43.88 ± 1.9, 43.84 ± 1.9, 43.66 ± 1.85 D, respectively. There was no statistically significant difference between the K readings (P = 0.901). When Lenstar was used for the corneal power measurements, MAE was 0.42 ± 0.33 D, but when simK of Sirius was used, it was 0.37 ± 0.32 D (the lowest MAE (0.36 ± 0.32 D) was achieved as a result of 5 mm K measurement), but it was not statistically significant (P = 0.892). Of all the K readings of Sirius and Lenstar, Sirius 5-mm zone K readings were the best in predicting a more precise IOL power. The corneal power measurements with the Scheimpflug camera combined with placido-disk corneal topography can be safely used for IOL power calculation.
NASA Astrophysics Data System (ADS)
Ben Yaish, Shai; Zlotnik, Alex; Raveh, Ido; Yehezkel, Oren; Belkin, Michael; Lahav, Karen; Zalevsky, Zeev
2009-02-01
We present novel technology for extension in depth of focus of imaging lenses for use in ophthalmic lenses correcting myopia, hyperopia with regular/irregular astigmatism and presbyopia. This technology produces continuous focus without appreciable loss of energy. It is incorporated as a coating or engraving on the surface for spectacles, contact or intraocular lenses. It was fabricated and tested in simulations and in clinical trials. From the various testing this technology seems to provide a satisfactory single-lens solution. Obtained performance is apparently better than those of existing multi/bifocal lenses and it is modular enough to provide solution to various ophthalmic applications.
Intra-ocular lens optical changes resulting from the loading of dexamethasone.
Artigas, José M; García-Domene, M Carmen; Navea, Amparo; Botella, Pablo; Fernández, Eduardo
2017-10-01
To study the optical changes on hydrogel-silicone intraocular lenses (IOLs) resulting from loading them with dexamethasone. We used prototype hydrogel(pHEMA)-silicone IOLs and loaded the matrices with an anti-inflammatory drug (dexamethasone). The optical properties we analyzed experimentally were a) modulation transfer function (MTF); b) spectral transmission; c) diopter power. These determinations were performed on drug-loaded IOLs, IOLs that had released the drug, and IOLs that had not been drug-loaded. Loading a hydrogel-silicone IOL with dexamethasone results in impairment of its optical qualities, in particular its MTF and spectral transmission, but not dioptric power. However, once the drug has been released, it almost recovers its initial optical properties.
Intra-ocular lens optical changes resulting from the loading of dexamethasone
Artigas, José M.; García-Domene, M. Carmen; Navea, Amparo; Botella, Pablo; Fernández, Eduardo
2017-01-01
To study the optical changes on hydrogel-silicone intraocular lenses (IOLs) resulting from loading them with dexamethasone. We used prototype hydrogel(pHEMA)-silicone IOLs and loaded the matrices with an anti-inflammatory drug (dexamethasone). The optical properties we analyzed experimentally were a) modulation transfer function (MTF); b) spectral transmission; c) diopter power. These determinations were performed on drug-loaded IOLs, IOLs that had released the drug, and IOLs that had not been drug-loaded. Loading a hydrogel-silicone IOL with dexamethasone results in impairment of its optical qualities, in particular its MTF and spectral transmission, but not dioptric power. However, once the drug has been released, it almost recovers its initial optical properties. PMID:29082089
AMO Teledioptric System for age-related macular degeneration
NASA Astrophysics Data System (ADS)
Chou, Jim-Son; Ting, Albert C.
1994-05-01
A 2.5 X magnification system consisting of a two-zone intraocular implant and a spectacle was developed, tested, and clinically tried by fifty patients with cataract ad age-related macular degeneration. Optical bench testing results and clinical data confirmed that the field of view of the system was 2.6 times wider than an equivalent external telescope. The study also demonstrated that the implant itself was clinically equivalent to a standard monofocal intraocular lens for cataract. The clinical study indicated that higher magnification without compromising the compactness and optical quality was needed as the disease progressed. Also, a sound vision rehabilitation process is important to provide patients the full benefits of the system.
Hayashi, Rijo; Hayashi, Shimmin; Arai, Kiyomi; Yoshida, Shinichirou; Chikuda, Makoto; Machida, Shigeki
2016-01-01
Purpose Blue light–filtering intraocular lenses (IOLs) are thought to protect the retina from blue light damage after cataract surgery, and the implantation of yellow-tinted IOLs has been commonly used in cataract surgery. To our knowledge, this is the first investigation measuring the long-term biostability of yellow-tinted IOLs using an in vitro system simulating natural intraocular environment. Methods Six hydrophobic acrylic IOLs, three clear IOLs, and three yellow-tinted IOLs were included in the study. Each yellow-tinted IOL was a matching counterpart of a clear IOL, with the only difference being the lens color. The IOLs were kept in conditions replicating the intraocular environment using a perfusion culture system for 7 months. Resolution, light transmittance rate, and the modulation transfer function (MTF) were measured before and after culturing. Surface roughness of the anterior and posterior surfaces was also measured. Results After culturing for 7 months, there were no changes in the resolution, the light transmittance rate, and MTF. The surface roughness of the anterior and posterior surfaces increased after culturing; however, this increase was clinically insignificant. There were no differences in surface roughness between the clear and yellow-tinted IOLs, either before or after culturing. Conclusions A novel in vitro system replicating intraocular environment was used to investigate the biostability of yellow-tinted IOLs. The surface roughness showed no clinically significant increase after culturing for 7 months. Translational Relevance This system is useful for evaluating the biostability of IOLs. PMID:27933221
Izak, Andrea M; Werner, Liliana; Pandey, Suresh K; Apple, David J
2004-07-01
To report the pathological findings in 14 human cadaver eyes implanted with a single-piece AcrySof(Alcon Laboratories) posterior chamber intraocular lens (IOL). David J. Apple, MD Laboratories for Ophthalmic Devices Research, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Fourteen human autopsy eyes implanted with a single-piece AcrySof (SA30AL) IOL were evaluated. The eyes were sectioned at the equatorial plane, and the anterior segment containing the IOL in the capsular bag was evaluated from a posterior perspective (Miyake-Apple view) and from an anterior perspective (surgeon's view) after removal of cornea and iris. They were then processed through paraffin, sectioned, and stained with hematoxylin-eosin, periodic acid-Schiff, and Masson's trichrome and examined under light microscopy. All IOLs had symmetric in-the-bag fixation. Slight decentration was measured in 1 eye, which also had an anterior capsule tear. Grade 1 anterior capsule opacification was present in 9 eyes. No central posterior capsule opacification or posterior capsule folds were observed in any eye. Soemmering's ring formation was observed in 5 eyes. Zonular stretch caused by different degrees of capsular bag contraction was present in 4 eyes without decentration of the IOL. Analyses of pseudophakic cadaver eyes from the posterior (Miyake-Apple) view, complemented by microscopic analyses, proved useful in the evaluation of IOL-capsular bag interaction. These studies are more important in cases of newly introduced lens designs.
Comparison of intraocular lens types for cataract surgery in eyes with uveitis
Ssemanda, Elizabeth; Lindsley, Kristina; Ervin, Ann-Margret; Kempen, John
2013-01-01
This is the protocol for a review and there is no abstract. The objectives are as follows: The aim of this systematic review is to summarize the effects of different IOLs after cataract surgery in uveitis patients. Alternative types of IOLs include PMMA, silicone, acrylic with or without heparin-surface modification. PMID:25013384
Energy Efficiency of a New Trifocal Intraocular Lens
NASA Astrophysics Data System (ADS)
Vega, F.; Alba-Bueno, F.; Millán, M. S.
2014-01-01
The light distribution among the far, intermediate and near foci of a new trifocal intraocular lens (IOL) is experimentally determined, as a function of the pupil size, from image analysis. The concept of focus energy efficiency is introduced because, in addition to the theoretical diffraction efficiency of the focus, it accounts for other factors that are naturally presented in the human eye such as the level of spherical aberration (SA) upon the IOL, light scattering at the diffractive steps or the depth of focus. The trifocal IOL is tested in-vitro in two eye models: the aberration-free ISO model, and a so called modified-ISO one that uses an artificial cornea with positive spherical SA in instead. The SA upon the IOL is measured with a Hartmann-Shack sensor and compared to the values of theoretical eye models. The results show, for large pupils, a notorious reduction of the energy efficiency of the far and near foci of the trifocal IOL due to two facts: the level of SA upon the IOL is larger than the value the lens is able to compensate for and there is significant light scattering at the diffractive steps. On the other hand, the energy efficiency of the intermediate focus for small pupils is enhanced by the contribution of the extended depth of focus of the near and far foci. Thus, while IOLs manufacturers tend to provide just the theoretical diffraction efficiency of the foci to show which would be the performance of the lens in terms of light distribution among the foci, our results put into evidence that this is better described by using the energy efficiency of the foci.
Eom, Youngsub; Ryu, Dongok; Kim, Dae Wook; Yang, Seul Ki; Song, Jong Suk; Kim, Sug-Whan; Kim, Hyo Myung
2016-10-01
To evaluate the toric intraocular lens (IOL) calculation considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and effective lens position (ELP). Two thousand samples of corneal parameters with keratometric astigmatism ≥ 1.0 D were obtained using bootstrap methods. The probability distributions for incision-induced keratometric and posterior corneal astigmatisms, as well as ELP were estimated from the literature review. The predicted residual astigmatism error using method D with an IOL add power calculator (IAPC) was compared with those derived using methods A, B, and C through Monte-Carlo simulation. Method A considered the keratometric astigmatism and incision-induced keratometric astigmatism, method B considered posterior corneal astigmatism in addition to the A method, method C considered incision-induced posterior corneal astigmatism in addition to the B method, and method D considered ELP in addition to the C method. To verify the IAPC used in this study, the predicted toric IOL cylinder power and its axis using the IAPC were compared with ray-tracing simulation results. The median magnitude of the predicted residual astigmatism error using method D (0.25 diopters [D]) was smaller than that derived using methods A (0.42 D), B (0.38 D), and C (0.28 D) respectively. Linear regression analysis indicated that the predicted toric IOL cylinder power and its axis had excellent goodness-of-fit between the IAPC and ray-tracing simulation. The IAPC is a simple but accurate method for predicting the toric IOL cylinder power and its axis considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and ELP.
Mester, U; Heinen, S; Kaymak, H
2010-09-01
Aspheric intraocular lenses (IOLs) aim to improve visual function and particularly contrast vision by neutralizing spherical aberration. One drawback of such IOLs is the enhanced sensitivity to decentration and tilt, which can deteriorate image quality. A total of 30 patients who received bilateral phacoemulsification before implantation of the aspheric lens FY-60AD (Hoya) were included in a prospective study. In 25 of the patients (50 eyes) the following parameters could be assessed 3 months after surgery: visual acuity, refraction, contrast sensitivity, pupil size, wavefront errors and decentration and tilt using a newly developed device. The functional results were very satisfying and comparable to results gained with other aspheric IOLs. The mean refraction was sph + 0.1 D (±0.7 D) and cyl 0.6 D (±0.8 D). The spherical equivalent was −0.2 D (±0.6 D). Wavefront measurements revealed a good compensation of the corneal spherical aberration but vertical and horizontal coma also showed opposing values in the cornea and IOL. The assessment of the lens position using the Purkinje meter demonstrated uncritical amounts of decentration and tilt. The mean amount of decentration was 0.2 mm±0.2 mm in the horizontal and vertical directions. The mean amount of tilt was 4.0±2.1° in horizontal and 3.0±2.5° in vertical directions. In a normal dioptric power range the aspheric IOL FY-60AD compensates the corneal spherical aberration very well with only minimal decentration. The slight tilt is symmetrical in both eyes and corresponds to the position of the crystalline lens in young eyes. This may contribute to our findings of compensated corneal coma.
Piñero, David P.; Camps, Vicente J.; Ramón, María L.; Mateo, Verónica; Pérez-Cambrodí, Rafael J.
2015-01-01
AIM To evaluate the prediction error in intraocular lens (IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP). METHODS Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany). In all cases, an adjusted IOL power (PIOLadj) was calculated based on Gaussian optics using a variable keratometric index value (nkadj) for the estimation of the corneal power (Pkadj) and on a new value for ELP (ELPadj) obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal) and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay I). RESULTS PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05). In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D) and limits of agreement (of 1.47 and -1.61 D) when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01) and was found to be dependent on axial length, anterior chamber depth and Pkadj. CONCLUSION Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors. PMID:26085998
Piñero, David P; Camps, Vicente J; Ramón, María L; Mateo, Verónica; Pérez-Cambrodí, Rafael J
2015-01-01
To evaluate the prediction error in intraocular lens (IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP). Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany). In all cases, an adjusted IOL power (PIOLadj) was calculated based on Gaussian optics using a variable keratometric index value (nkadj) for the estimation of the corneal power (Pkadj) and on a new value for ELP (ELPadj) obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal) and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay I). PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05). In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D) and limits of agreement (of 1.47 and -1.61 D) when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01) and was found to be dependent on axial length, anterior chamber depth and Pkadj. Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors.
1991-01-01
Visual loss or disability from cataract represents a massive public health and socioeconomic problem in most developing countries. At present, some 13.5 million cases require treatment and this number will increase, as most countries in the Third World are unable to cope with both the backlog and new cases. Cataract extraction with intraocular lens (IOL) implantation is now the established and preferred method in industrialized countries. The introduction of IOLs in developing countries, however, depends on their having adequately trained manpower and facilities (equipment and supplies, including IOLs) for surgery. This will inevitably increase the cost per operated case which, despite the scarce resources for cataract surgery in many developing countries, may be justified by the improved restoration of the patient's vision. Experience has led to the following generic designs for IOLs: the one-piece or three-piece C-loop polymethylmethacrylate (PMMA) posterior chamber lens, which is the current favourite; and, the flexible or rigid one-piece all-PMMA anterior chamber lens, which is a valid alternative in many situations. Further scientific evaluation of the use of these lenses in a wide variety of settings in developing countries is required. Operations research is also needed in order better to define and standardize the various steps and procedures in the surgical and post-operative management of IOL implantation in Third World settings. Meanwhile, the following should be available to ensure safe and good quality cataract surgery using IOLs in developing countries: properly trained surgeons; the needed facilities and equipment with regular supplies; a good quality lens of appropriate design; and the necessary means for careful follow-up of operated patients. PMID:1786616
Image-guided system versus manual marking for toric intraocular lens alignment in cataract surgery.
Webers, Valentijn S C; Bauer, Noel J C; Visser, Nienke; Berendschot, Tos T J M; van den Biggelaar, Frank J H M; Nuijts, Rudy M M A
2017-06-01
To compare the accuracy of toric intraocular lens (IOL) alignment using the Verion Image-Guided System versus a conventional manual ink-marking procedure. University Eye Clinic Maastricht, Maastricht, the Netherlands. Prospective randomized clinical trial. Eyes with regular corneal astigmatism of at least 1.25 diopters (D) that required cataract surgery and toric IOL implantation (Acrysof SN6AT3-T9) were randomly assigned to the image-guided group or the manual-marking group. The primary outcome was the alignment of the toric IOL based on preoperative images and images taken immediately after surgery. Secondary outcome measures were residual astigmatism, uncorrected distance visual acuity (UDVA), and complications. The study enrolled 36 eyes (24 patients). The mean toric IOL misalignment was significantly less in the image-guided group than in the manual group 1 hour (1.3 degrees ± 1.6 [SD] versus 2.8 ± 1.8 degrees; P = .02) and 3 months (1.7 ± 1.5 degrees versus 3.1 ± 2.1 degrees; P < .05) postoperatively. The mean residual refractive cylinder was -0.36 ± 0.32 D and -0.47 ± 0.28 D in the image-guided group and manual group, respectively (P > .05). The mean UDVA was 0.03 ± 0.10 logarithm of minimum angle of resolution (logMAR) and 0.04 ± 0.09 logMAR, respectively (both P > .05). No intraoperative complications occurred during any surgery. The IOL misalignment was significantly less with digital marking than with manual marking; this did not result in a better UDVA or lower residual refractive astigmatism. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Fakhry, Mohamed A; El Shazly, Malak I
2011-01-01
To compare torsional versus combined torsional and conventional ultrasound modes in hard cataract surgery regarding ultrasound energy and time and effect on corneal endothelium. Kasr El Aini hospital, Cairo University, and International Eye Hospital, Cairo, Egypt. Ninety-eight eyes of 63 patients were enrolled in this prospective comparative randomized masked clinical study. All eyes had nuclear cataracts of grades III and IV using the Lens Opacities Classification System III (LOCS III). Two groups were included, each having an equal number of eyes (49). The treatment for group A was combined torsional and conventional US mode phacoemulsification, and for group B torsional US mode phacoemulsification only. Pre- and post-operative assessments included best corrected visual acuity (BCVA), intraocular pressure (IOP), slit-lamp evaluation, and fundoscopic evaluation. Endothelial cell density (ECD) and central corneal thickness (CCT) were measured preoperatively, 1 day, 7 days, and 1 month postoperatively. All eyes were operated on using the Alcon Infiniti System (Alcon, Fort Worth, TX) with the quick chop technique. All eyes were implanted with AcrySof SA60AT (Alcon) intraocular lens (IOL). The main phaco outcome parameters included the mean ultrasound time (UST), the mean cumulative dissipated energy (CDE), and the percent of average torsional amplitude in position 3 (%TUSiP3). Improvement in BCVA was statistically significant in both groups (P < 0.001). Comparing UST and CDE for both groups revealed results favoring the pure torsional group (P = 0.002 and P < 0.001 for UST; P = 0.058 and P = 0.009 for CDE). As for %TUSiP3, readings were higher for the pure torsional group (P = 0.03 and P = 0.01). All changes of CCT, and ECD over time were found statistically significant using one-way ANOVA testing (P < 0.001). Both modes are safe in hard cataract surgery, however the pure torsional mode showed less US energy used.
Fakhry, Mohamed A; Shazly, Malak I El
2011-01-01
Purpose To compare torsional versus combined torsional and conventional ultrasound modes in hard cataract surgery regarding ultrasound energy and time and effect on corneal endothelium. Settings Kasr El Aini hospital, Cairo University, and International Eye Hospital, Cairo, Egypt. Methodology Ninety-eight eyes of 63 patients were enrolled in this prospective comparative randomized masked clinical study. All eyes had nuclear cataracts of grades III and IV using the Lens Opacities Classification System III (LOCS III). Two groups were included, each having an equal number of eyes (49). The treatment for group A was combined torsional and conventional US mode phacoemulsification, and for group B torsional US mode phacoemulsification only. Pre- and post-operative assessments included best corrected visual acuity (BCVA), intraocular pressure (IOP), slit-lamp evaluation, and fundoscopic evaluation. Endothelial cell density (ECD) and central corneal thickness (CCT) were measured preoperatively, 1 day, 7 days, and 1 month postoperatively. All eyes were operated on using the Alcon Infiniti System (Alcon, Fort Worth, TX) with the quick chop technique. All eyes were implanted with AcrySof SA60AT (Alcon) intraocular lens (IOL). The main phaco outcome parameters included the mean ultrasound time (UST), the mean cumulative dissipated energy (CDE), and the percent of average torsional amplitude in position 3 (%TUSiP3). Results Improvement in BCVA was statistically significant in both groups (P < 0.001). Comparing UST and CDE for both groups revealed results favoring the pure torsional group (P = 0.002 and P < 0.001 for UST; P = 0.058 and P = 0.009 for CDE). As for %TUSiP3, readings were higher for the pure torsional group (P = 0.03 and P = 0.01). All changes of CCT, and ECD over time were found statistically significant using one-way ANOVA testing (P < 0.001). Conclusion Both modes are safe in hard cataract surgery, however the pure torsional mode showed less US energy used. PMID:21792288
Hsia, Yen C; Moghimi, Sasan; Coh, Paul; Chen, Rebecca; Masis, Marisse; Lin, Shan C
2017-07-01
To evaluate intraocular pressure (IOP) change after cataract surgery in eyes with open-angle glaucoma (OAG) and its relationship to angle and anterior segment parameters measured by anterior segment optical coherence tomography (AS-OCT). University of California, San Francisco, California, USA. Prospective case series. Eyes were placed into a narrow-angle group or open-angle group based on gonioscopy grading. Biometric parameters were measured using AS-OCT (Visante) preoperatively, and IOP 4 months after surgery was obtained. The IOP change and its relationship to AS-OCT parameters were evaluated. Eighty-one eyes of 69 patients were enrolled. The mean age of the patients was 76.8 years. The preoperative IOP was 15.02 mm Hg on 1.89 glaucoma medications. The average mean deviation of preoperative visual field was -4.58 dB. The mean IOP reduction was 2.1 mm Hg (12.8%) from a preoperative mean of 15.0 mm Hg. The IOP reduction was significantly greater in eyes with narrow angles than in eyes with open angles (20.4% versus 8.0%) (P = .002). In multivariate analysis, preoperative IOP (β = -0.53, P < .001, R 2 = 0.40), angle-opening distance at 500 mm (β = 5.83, P = .02, R 2 = 0.45), angle-opening distance at 750 mm (β = 5.82, P = .001, R 2 = 0.52), and lens vault (β = -0.002, P = .009, R 2 = 0.47) were associated with IOP reduction postoperatively. In eyes with OAG, IOP reduction after cataract surgery was greater in eyes with narrower angles. Preoperative IOP, angle-opening distance, and lens vault were predictors for IOP reduction. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Snellingen, T; Shrestha, J K; Huq, F; Husain, R; Koirala, S; Rao, G N; Pokhrel, R P; Kolstad, A; Upadhyay, M P; Apple, D J; Arnesen, E; Cheng, H; Olsen, E G; Vogel, M
2000-02-01
To determine clinical outcomes of primary intracapsular cataract surgery with and without implantation of anterior chamber lenses. A multicenter randomized clinical trial. One thousand two hundred twenty-nine male and female patients 40-75 years of age with senile cataract. Study patients were recruited from screening eye camps and outpatient clinics. Randomization to the two treatment groups was performed after screening for predetermined inclusion and exclusion criteria. Demographics, visual acuity, intraocular pressures, and corneal endothelial cell data were recorded before surgery and at 6 weeks, 12 months, and 24 months after surgery. Monitoring of the study was secured by a standardized image documentation procedure on all patients using the IMAGEnet digital imaging system. Analysis of corneal endothelial cell images was performed with the Cell Soft software (Topcon Corporation, Japan). Visual acuity and central corneal endothelial cell loss. The patients were randomized to intraocular lens (IOL; n = 616) and no IOL (n = 613) implantation. Surgical complications were reported in 177 (14.4%) patients (IOL = 14.8%; no IOL = 14.0%). The most frequent complication observed was vitreous loss which occurred in 10.3% of eyes (IOL = 11.2%; no IOL = 9.5%). At the final examination (2 years after surgery), 88% of the operated eyes had a best corrected vision of 6/18 or better (IOL = 88.8%; no IOL = 86.6%). Analysis of corneal endothelial cell data showed a small but significantly greater cell loss 6 weeks after surgery in eyes with IOL compared with those without IOL, but no overall difference was found between the treatment groups in the long term follow-up. The findings indicate that there is a rationale for the use of anterior chamber intraocular lenses in primary intracapsular cataract surgery.
Villemont, A-S; Kocaba, V; Janin-Manificat, H; Abouaf, L; Poli, M; Marty, A-S; Rabilloud, M; Fleury, J; Burillon, C
2017-09-01
To evaluate the long-term outcomes of artificial iris intraocular lenses sutured to the sclera for managing traumatic aphakia and aniridia. All consecutive cases receiving a Morcher ® combination implant from June 2008 to February 2016 in Edouard-Herriot Hospital (Lyon, France) were included in this single-center retrospective study. Visual acuity, subjective degree of glare, quality of life and surgical complications were evaluated. Seventeen eyes of 17 patients were included, among which 82% were male. The mean age was 42 years. The injuries consisted of 23.5% contusion and 70.5% open globe injuries, of which 41% were globe ruptures. There was one postoperative case. A penetrating keratoplasty was performed at the same time for eight eyes. The mean follow-up was 32 months. Best-corrected visual acuity improved in 41.2%, remained the same in 17.6% and decreased in 41.2% of our cases. Distance vision averaged 1±0.25 line better and near vision 2.2±0.32 lines better when visual acuity was quantifiable before surgery. Glare improved in 80% of patients and remained stable in 20%, decreasing on average from 3.3/5 [min. 3-max. 4; SD: 0.48] before surgery to 1.9/5 [min. 0-max. 4; SD: 1.197] after surgery. Regarding the esthetic results, 78% of the patients declared themselves reasonably to very satisfied; 57% reported no limitation of activities of daily living, and 43% reported mild limitation. Ocular hypertension and glaucoma, found in 40% of eyes, were the main postoperative complications. Implantation of prosthetic iris device combined with an intraocular lens appears to be safe and effective in reducing glare disability and improving visual acuity. Close, long-term monitoring is essential for the success of this surgery. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Kim, Min; Lee, Dong H; Koh, Hyoung J; Lee, Sung C; Kim, Sung S
2015-07-01
To report short-term surgical outcomes of single-stage simultaneous rescue and sutureless intrascleral fixation of dislocated intraocular lens (IOLs). Sixteen eyes of 16 patients who underwent simultaneous rescue and intrascleral fixation of dislocated 3-piece IOLs were retrospectively evaluated. Partial thickness limbal-based scleral flaps (2.0 × 2.0 mm) were created, and a 22-gauge round needle was used to create a sclerotomy at 1.5 mm from the limbus under the previously created scleral flap, and a 23-gauge trans pars plana vitrectomy was performed. Bimanual maneuvers using two 23-gauge end-grasping forceps under chandelier illumination and a wide-angle viewing system enabled 1 step rescue of IOLs from the posterior vitreous cavity with 1 hand and simultaneous haptic externalization through sclerotomy with the other hand. An externalized haptic was placed into the 3-mm intrascleral tunnel created using a bent 26-gauge needle. Fibrin glue was used to fixate haptics and close the scleral flaps. Intraocular lenses were successfully rescued and sclera-fixated through intrascleral tunnels in all 16 eyes (mean age, 56.56 ± 19.89 years). The mean preoperative logarithm of the minimum angle of resolution best-corrected visual acuity was 0.92 ± 0.68, and this significantly improved at 6 months to 0.289 ± 0.36 (P = 0.003). During the follow-up period (10.1 ± 3.21 months), no significant change of endothelial cell count or central foveal thickness was noted postoperatively (P = 0.203 and P = 0.979, respectively). There were no significant postoperative complications such as IOL dislocation, IOL decentration, retinal detachment, endophthalmitis, or postoperative hypotony. Simultaneous rescue and sutureless intrascleral haptic fixation of dislocated 3-piece IOLs using bimanual maneuvers is an effective, safe, and minimally invasive surgical method to rescue and fixate the dislocated IOL without further explant.
Central Corneal Thickness and its Relationship to Intra-Ocular and Epidmiological Determinants.
Tayyab, Ali; Masrur, Amena; Afzal, Farooq; Iqbal, Fyza; Naseem, Kamran
2016-06-01
To measure central corneal thickness in Pakistani population and determine its relationship to intra-ocular pressure, age, gender and ethnicity. Cross-sectional observation study. Pakistan Institute of Medical Sciences, Islamabad, Pakistan, between December 2013 and February 2015. The right eyes of 1000 cases (496 males and 504 females) were recruited for this study. Inclusion criteria were Pashtun or Punjabi ethnicity, intra-ocular pressure < 22 mmHg, gonioscopically open angles, cup-disk-ratio < 0.5, and age matched normal visual fields. Cases with prior ocular surgery, contact lens use, corneal pathologies, myopia or hypermetropia > ±3.0 diopters, astigmatism of > ±1.0 diopters were excluded. Central corneal thickness was measured using a TopCon non-contact specular microscope. Intra-ocular pressure was measured using Goldmann applanation tonometer. Frequency distribution, test of significance, and regression analysis was carried out using Statistical Package for Social Sciences version 20.0. Mean age was 47.31 ±11.78 years. Ethnic composition was 51.6% (n=516) Pashtun and 48.4% (n=484) Punjabi. The mean central corneal thickness was 503.96 (±12.47) µm, while the mean intra-ocular pressure was 15.61 (±2.68) mmHg. Regression analysis showed a significant association between central corneal thickness and intra-ocular pressure (p=0.00) and age (p=0.00). A±100 µchange in central corneal thickness was associated with change in IOPof ±3.30 mmHg, whereas central corneal thickness decreased by 0.12 µm per year. No significant association could be established between central corneal thickness and ethnicity (p=0.19). Central corneal thickness of the studied races was comparable to non-Caucasians which affects intra-ocular pressure measurements, and decreases with increasing age. No relationship was observed between central corneal thickness and ethnicity or gender.
von Krosigk, F; Steinmetz, A; Ellenberger, C; Oechtering, G
2012-01-01
This two-part study describes the clinical usefulness and value of ultrasound and magnetic resonance imaging (MRI) in dogs and cats with ocular (n=30) and orbital diseases (n=31). MRI and ultrasonography characteristics are described in single cases with ocular and orbital disease. Ultrasonography and MRI were performed in 15 dogs and 15 cats with intraocular neoplasia or intraocular inflammatory disease. In all patients with intraocular neoplasia, sonography revealed masses with increased echogenicity and fairly uniform echotexture, thus allowing the tentative diagnosis of an intraocular tumour. In these cases, MRI often proved to be a valuable diagnostic tool in showing the complete extent of intraocular lesion. An additional benefit of MRI was seen in the tissue characterization of tumours based on MRI signal characteristics and pattern of contrast enhancement. Discreet intraocular inflammatory alterations, in particular to the anterior and posterior segment of the eyeball, were more clearly shown by ultrasound than by MRI. Neoplasia could be excluded and inflammatory disease was successfully diagnosed using MRI due to the different image sequences with or without contrast medium administration. Traumatic ruptures of the lens capsule and the globe after trauma were depicted more clearly with MRI. When opacity of the anterior eye segment is present, various intraocular changes can be quickly diagnosed by ultrasound with high accuracy, without requiring anaesthesia of the patient. MRI of the globe allows differentiation of diverse pathologies, gives detailed information of infiltration in orbital structures and the exact degree of ocular lesions after trauma. This additional evidence often makes it easier to predict the correct prognosis and choose the best therapy.
Uveitis-Glaucoma-Hyphaema Syndrome. General review.
Zemba, Mihail; Camburu, Georgiana
2017-01-01
Uveitis-Glaucoma-Hyphaema Syndrome (UGH syndrome, or "Ellingson" Syndrome) is a rare condition caused by the mechanical trauma of an intraocular lens malpositioned over adjacent structures (iris, ciliary body, iridocorneal angle), leading to a spectrum of iris transillumination defects, microhyphaemas and pigmentary dispersion, concomitant with elevated intraocular pressure (IOP). UGH Syndrome can also be characterized by chronic inflammation, secondary iris neovascularization, cystoid macular edema (CME). The fundamental step in the pathogenesis of UGH syndrome appears to arise from repetitive mechanical iris trauma by a malpositioned or subluxed IOL. These patients have uncomplicated cataract implants and return for episodes of blurry vision weeks to months after surgery. This may be accompanied by pain, photophobia, erythropsia, anterior uveitis, hyphaema along with raised intraocular pressure. A careful history and examination, as well as appropriate investigations can confirm the diagnostic. Treatment options are IOL Explantation exchange, topical and systemic medication, and cyclophotocoagulation, the placement of a Capsular Tension Ring to redistribute zonular tension and Anti-vascular endothelial growth factor (anti-VEGF) Therapy.
Surgical technique for management of isolated lenticular coloboma with high corneal astigmatism.
Singh, Simar Rajan; Yangzes, Sonam; Gupta, Rohit; Ram, Jagat
2018-04-01
We describe a surgical technique for the correction of isolated congenital lenticular coloboma associated with high corneal astigmatism. Transscleral fixation of the capsular bag with a single eyelet Cionni capsular tension ring was followed by in-the-bag implantation of a toric intraocular lens (IOL). This lead to complete correction of the lenticular defect and perfect alignment of the toric lens. In this case, the child attained an unaided distance visual acuity of 20/30 following amblyopia therapy and a well-aligned toric IOL at 12 months of follow-up. This technique can be used in cases with concomitant lenticular coloboma and significant corneal astigmatism.
Surgical technique for management of isolated lenticular coloboma with high corneal astigmatism
Singh, Simar Rajan; Yangzes, Sonam; Gupta, Rohit; Ram, Jagat
2018-01-01
We describe a surgical technique for the correction of isolated congenital lenticular coloboma associated with high corneal astigmatism. Transscleral fixation of the capsular bag with a single eyelet Cionni capsular tension ring was followed by in-the-bag implantation of a toric intraocular lens (IOL). This lead to complete correction of the lenticular defect and perfect alignment of the toric lens. In this case, the child attained an unaided distance visual acuity of 20/30 following amblyopia therapy and a well-aligned toric IOL at 12 months of follow-up. This technique can be used in cases with concomitant lenticular coloboma and significant corneal astigmatism. PMID:29582820
Agresta, Blaise; Knorz, Michael C; Kohnen, Thomas; Donatti, Christina; Jackson, Daniel
2012-06-01
To evaluate uncorrected distance visual acuity (UDVA) as well as uncorrected near visual acuity (UNVA) as outcomes in treating presbyopic cataract patients to assist clinicians and ophthalmologists in their decision-making process regarding available interventions. Medline, Embase, and Evidence Based Medicine Reviews were systematically reviewed to identify studies reporting changes in UDVA and UNVA after cataract surgery in presbyopic patients. Strict inclusion/exclusion criteria were used to exclude any studies not reporting uncorrected visual acuity in a presbyopic population with cataracts implanted with multifocal intraocular lenses (IOLs). Relevant outcomes (UDVA and UNVA) were identified from the studies retrieved through the systematic review process. Twenty-nine studies were identified that reported uncorrected visual acuities, including one study that reported uncorrected intermediate visual acuity. Nine brands of multifocal IOLs were identified in the search. All studies identified in the literature search reported improvements in UDVA and UNVA following multifocal IOL implantation. The largest improvements in visual acuity were reported using the Rayner M-Flex lens (Rayner Intraocular Lenses Ltd) (UDVA, binocular: 1.05 logMAR, monocular: 0.92 logMAR; UNVA, binocular and monocular: 0.83 logMAR) and the smallest improvements were reported using the Acri.LISA lens (Carl Zeiss Meditec) (UDVA, 0.21 decimal; UNVA, 0.51 decimal). The results of this systematic review show the aggregate of studies reporting a beneficial increase in UDVA and UNVA with the use of multifocal IOLs in cataract patients with presbyopia, hence providing evidence to support the hypothesis that multifocal IOLs increase UDVA and UNVA in cataract patients. Copyright 2012, SLACK Incorporated.
Eye injury risk associated with remote control toy helicopter blades.
Alphonse, Vanessa D; Kemper, Andrew R; Rowson, Steven; Duma, Stefan M
2012-01-01
Eye injuries can be caused by a variety of consumer products and toys. Recently, indoor remote controlled (RC) toy helicopters have become very popular. The purpose of this study is to quantify eye injury risk associated with five commercially available RC toy helicopter blades. An experimental matrix of 25 tests was developed to test five different RC toy helicopter blades at full battery power on six postmortem human eyes. A pressure sensor inserted through the optic nerve measured intraocular pressure. Corneal abrasion was assessed post-impact using fluorescein dye. Intraocular pressure was correlated to injury risk for hyphema, lens damage, retinal damage, and globe rupture using published risk functions. All tests resulted in corneal abrasions; however, no other injuries were observed. The 25 tests produced an increase intraocular pressure between 15.2 kPa and 99.3 kPa (114.3 mmHg and 744.7 mmHg). Calculated blade velocities ranged between 16.0 m/s and 25.4 m/s. Injury risk for hyphema was a maximum of 0.2%. Injury risk for lens damage, retinal damage, and globe rupture was 0.0% for all tests. Blade design parameters such as length and mass did not affect the risk of eye injury. This is the first study to quantify the risk of eye injury from RC toy helicopter blades. While corneal abrasions were observed, more serious eye injuries were neither observed nor predicted to have occurred. Results from this study are critical for establishing safe design thresholds for RC toy helicopter blades so that more serious injuries can be prevented.
Intraocular Lens Fragmentation Using Femtosecond Laser: An In Vitro Study
Bala, Chandra; Shi, Jeffrey; Meades, Kerrie
2015-01-01
Purpose: To transect intraocular lenses (IOLs) using a femtosecond laser in cadaveric human eyes. To determine the optimal in vitro settings, to detect and characterize gasses or particles generated during this process. Methods: A femtosecond laser was used to transect hydrophobic and hydrophilic acrylic lenses. The settings required to enable easy separation of the lens fragment were determined. The gasses and particles generated were analysed using gas chromatography mass spectrometer (GC-MS) and total organic carbon analyzer (TOC), respectively. Results: In vitro the IOL fragments easily separated at the lowest commercially available energy setting of 1 μJ, 8-μm spot, and 2-μm line separation. No particles were detected in the 0.5- to 900-μm range. No significant gasses or other organic breakdown by products were detected at this setting. At much higher energy levels 12 μJ (4 × 6 μm spot and line separation) significant pyrolytic products were detected, which could be harmful to the eye. In cadaveric explanted IOL capsule complex the laser pulses could be applied through the capsule to the IOL and successfully fragment the IOL. Conclusion: IOL transection is feasible with femtosecond lasers. Further in vivo animal studies are required to confirm safety. Translational Relevance: In clinical practice there are a number of large intraocular lenses that can be difficult to explant. This in-vitro study examines the possibility of transecting the lasers quickly using femtosecond lasers. If in-vivo studies are successful, then this innovation could help ophthalmic surgeons in IOL explantation. PMID:26101721
Ito, Misae; Shimizu, Kimiya
2009-09-01
To the compare the reading ability after bilateral cataract surgery in patients who had pseudophakic monovision achieved by monofocal intraocular lens (IOL) implantation and patients who had refractive multifocal IOL implantation. Department of Ophthalmology, Kitasato University Hospital, Kanagawa, Japan. This study evaluated patients who had bilateral cataract surgery using the monovision method with monofocal IOL implantation to correct presbyopia (monovision group) or who had bilateral cataract surgery with refractive multifocal IOL implantation (multifocal group). In the monovision group, the dominant eye was corrected for distance vision and the nondominant eye for near vision. The maximum reading speed, critical character size, and reading acuity were measured binocularly without refractive correction using MNREAD-J acuity charts. The monovision group comprised 38 patients and the multifocal group, 22 patients. The mean maximum reading speed was 350.5 characters per minute (cpm) +/- 62.3 (SD) in the monovision group and 355.0 +/- 53.3 cpm in the multifocal group; the difference was not statistically significant. The mean critical character size was 0.24 +/- 0.12 logMAR and 0.40 +/- 0.16 logMAR, respectively (P<.05). The mean reading acuity was 0.05 +/- 0.12 logMAR and 0.19 +/- 0.11 logMAR, respectively (P<.01). The monovision group had better critical character size and reading acuity results. The monovision method group had better reading ability; however, careful patient selection is essential.
Ryu, Ik Hee; Han, Jinu; Lee, Hyung Keun; Kim, Jin Kook; Han, Sueng-Han
2014-04-01
To evaluate the change of accommodation-convergence parameters after implantation of Artisan phakic intraocular lens (PIOL). Prospective study for the patients with the Artisan PIOL implantation was performed. A total of 37 patients (3 males and 34 females) enrolled the study. Preoperatively, convergence amplitude, the stimulus accommodative convergence per unit of accommodation (AC/A) ratio and the near point of convergence (NPC) were evaluated. After the Artisan PIOL implantation, the identical evaluations were repeated at 1 week, 1, 3, and 6 months after the surgery. Mean age was 24.3 ± 4.8 years old, and preoperative refractive error was -8.92 ± 4.13 diopters (D). After the implantation, mean refractive errors significantly decreased to within ±1.00 D, and noticeable complications were not found. The convergence amplitude and the stimulus AC/A ratio increased 1 month after the surgery, but progressively stabilized afterward to near preoperative values. NPC didn't show any significant change over follow-up period up to 6 months. These results regarding implantation of the Artisan PIOL revealed the increase of accommodation-convergence relationship within first 1 month after the surgery, but progressive stabilization was noted during follow-up periods.
Mohan, Sujatha; John, Bina; Rajan, Mohan; Malkani, Harsha; Nagalekshmi, S V; Singh, Siddhartha
2017-06-01
The aim of this study is to analyze the postoperative visual outcomes of fibrin glue-assisted, suture-less posterior chamber (PC) intraocular lens (IOL) implantation technique in eyes with inadequate capsule support at a tertiary eye care hospital in South India. This is a retrospective, nonrandomized case series. This study analyzes 94 eyes which underwent PC-IOL implantation by fibrin glue-assisted, suture-less technique. All patients who had IOL implants by the fibrin glue-assisted PC-IOL technique from August 2009 to January 2014 were included in the study. Intra- and post-operative complications were analyzed. The postoperative best spectacle-corrected visual acuity (BSCVA) was evaluated and recorded at the end of 6 months. The data were analyzed using SPSS version 16.1 (SPSS Inc., Chicago, Illinois, USA) using two sample paired t-test and independent t-test. A total of 94 eyes of 92 patients that underwent glued IOL implantation over a period of 5 years were analyzed. Out of 94 eyes, 77 eyes (84.6%) maintained or improved on their preoperative BSCVA (P = 0.012). We conclude that glued IOL implantation is a feasible option in rehabilitating patients with aphakia without adequate capsular support.
INTRAOCULAR LENS POSITION IN COMBINED PHACOEMULSIFICATION AND VITREORETINAL SURGERY.
Ozates, Serdar; Kiziltoprak, Hasan; Koc, Mustafa; Uzel, Mehmet Murat; Teke, Mehmet Yasin
2017-10-09
To assess the decentration and angle of tilt of the intraocular lens (IOL) according to the intravitreal tamponade types used in combined phacoemulsification and vitreoretinal surgery. This prospective and randomized clinical study involved 73 eyes of 69 patients who underwent combined vitreoretinal surgery. Eyes with intravitreal tamponades formed the study group and eyes without intravitreal tamponades formed the control group. The study group was further divided into silicone oil and gas tamponade subgroups. Cross-sectional IOL images were captured using a Pentacam HR (Oculus, Germany) and tilt and decentration were calculated with Adobe Photoshop software (Adobe, San Jose, CA). The mean angle of tilt and decentration at the vertical meridian were significantly higher in both tamponade groups than in the control group (P < 0.05 for all). No significant difference was observed among the groups regarding IOL position parameters at the horizontal meridian (P > 0.05). When comparing the silicone oil and gas tamponade subgroups, no significant differences were noted on the position of IOL at both meridians (P > 0.05 for all). Intravitreal tamponades have an important effect on the position of IOL in combined vitreoretinal surgery. Silicone oil and gas tamponades may induce postoperative tilt and decentration of one-piece acrylic IOLs.
Clinical Outcomes after Binocular Implantation of a New Trifocal Diffractive Intraocular Lens
Kretz, Florian T. A.; Breyer, Detlev; Diakonis, Vasilios F.; Klabe, Karsten; Henke, Franziska; Auffarth, Gerd U.; Kaymak, Hakan
2015-01-01
Purpose. To evaluate visual, refractive, and contrast sensitivity outcomes, as well as the incidence of pseudophakic photic phenomena and patient satisfaction after bilateral diffractive trifocal intraocular lens (IOL) implantation. Methods. This prospective nonrandomized study included consecutive patients undergoing cataract surgery with bilateral implantation of a diffractive trifocal IOL (AT LISA tri 839MP, Carl Zeiss Meditec). Distance, intermediate, and near visual outcomes were evaluated as well as the defocus curve and the refractive outcomes 3 months after surgery. Photopic and mesopic contrast sensitivity, patient satisfaction, and halo perception were also evaluated. Results. Seventy-six eyes of 38 patients were included; 90% of eyes showed a spherical equivalent within ±0.50 diopters 3 months after surgery. All patients had a binocular uncorrected distance visual acuity of 0.00 LogMAR or better and a binocular uncorrected intermediate visual acuity of 0.10 LogMAR or better, 3 months after surgery. Furthermore, 85% of patients achieved a binocular uncorrected near visual acuity of 0.10 LogMAR or better. Conclusions. Trifocal diffractive IOL implantation seems to provide an effective restoration of visual function for far, intermediate, and near distances, providing high levels of visual quality and patient satisfaction. PMID:26301104
Tonopen XL assessment of intraocular pressure through silicone hydrogel contact lenses.
Schornack, Muriel; Rice, Melissa; Hodge, David
2012-09-01
To assess the accuracy of Tonopen XL measurement of intraocular pressure (IOP) through low-power (-0.25 to -3.00) and high power (-3.25 to -6.00) silicone hydrogel lenses of 3 different materials (galyfilcon A, senofilcon A, and lotrafilcon B). Seventy-eight patients were recruited for participation in this study. All were habitual wearers of silicone hydrogel contact lenses, and none had been diagnosed with glaucoma, ocular hypertension, or anterior surface disease. IOP was measured with and without lenses in place in the right eye only. Patients were randomized to initial measurement either with or without the lens in place. A single examiner collected all data. No statistically significant differences were noted between IOP measured without lenses and IOP measured through low-power lotrafilcon B lenses or high-power or low-power galyfilcon A and senofilcon A lenses. However, we did find a statistically significant difference between IOP measured without lenses and IOP measured through high-power lotrafilcon B lenses. In general, Tonopen XL measurement of IOP through silicone hydrogel lenses may be sufficiently accurate for clinical purposes. However, Tonopen XL may overestimate IOP if performed through a silicone hydrogel lens of relatively high modulus.
Posterior chamber lens implantation with scleral fixation in children with traumatic cataract.
Caca, Ihsan; Sahin, Alparslan; Ari, Seyhmus; Alakus, Fuat
2011-01-01
To evaluate the outcomes of posterior chamber lens implantation with scleral fixation (SF-PCIOL) in children with traumatic cataract. Twenty-four eyes of 24 cases were included. All patients had corneal or corneoscleral lacerations that were primarily repaired. Traumatic cataract subsequently developed and SF-PCIOL was performed due to insufficient posterior capsule support. The average age of the patients was 5.8 years (range: 4 to 10 years). All cases had SF-PCIOL implanted via internal route using triangular double scleral flaps made of 9-0 polypropylene after a complete anterior vitrectomy. Average follow-up was 14.6 ± 4.3 months (range: 11 to 18 months). Visual acuity was increased at the last visit in 23 (96%) patients. Common postoperative complications were fibrinous reaction in 6 (25%) patients, transient intraocular pressure increase in 4 (17%) patients, membrane formation requiring removal in 1 (4%) patient, transient intraocular hemorrhage as vitreous hemorrhage in 1 (4%) patient, and retinal detachment in 1 (4%) patient after the postoperative second month. SF-PCIOL is an effective and reliable method in patients with pediatric traumatic cataract who had insufficient posterior capsule support. Copyright 2011, SLACK Incorporated.
Cyclodextrin-containing hydrogels as an intraocular lens for sustained drug release
Li, Xiao; Zhao, Yang; Wang, Kaijie; Yang, Xiaohui; Zhu, Siquan
2017-01-01
To improve the efficacy of anti-inflammatory factors in patients who undergo cataract surgery, poly(2-hydroxyethyl methacrylate-co-methyl methacrylate) (p(HEMA-co-MMA)) hydrogels containing β-cyclodextrin (β-CD) (pHEMA/MMA/β-CD) were designed and prepared as intraocular lens (IOLs) biomaterials that could be loaded with and achieve the sustained release of dexamethasone. A series of pHEMA/MMA/β-CD copolymers containing different ratios of β-CD (range, 2.77 to 10.24 wt.%) were obtained using thermal polymerization. The polymers had high transmittance at visible wavelengths and good biocompatibility with mouse connective tissue fibroblasts. Drug loading and release studies demonstrated that introducing β-CD into hydrogels increased loading efficiency and achieved the sustained release of the drug. Administering β-CD via hydrogels increased the equilibrium swelling ratio, elastic modulus and tensile strength. In addition, β-CD increased the hydrophilicity of the hydrogels, resulting in a lower water contact angle and higher cellular adhesion to the hydrogels. In summary, pHEMA/MMA/β-CD hydrogels show great potential as IOL biomaterials that are capable of maintaining the sustained release of anti-inflammatory drugs after cataract surgery. PMID:29244868
The measurement of intraocular pressure over positive soft contact lenses by rebound tonometry.
Zeri, Fabrizio; De Cusatis, Mario; Lupelli, Luigi; Swann, Peter Graham
2016-01-01
To investigate if the accuracy of intraocular pressure (IOP) measurements using rebound tonometry over disposable hydrogel (etafilcon A) contact lenses (CL) is affected by the positive power of the CLs. The experimental group comprised 26 subjects, (8 male, 18 female). IOP measurements were undertaken on the subjects' right eyes in random order using a Rebound Tonometer (ICare). The CLs had powers of +2.00D and +6.00D. Measurements were taken over each contact lens and also before and after the CLs had been worn. The IOP measure obtained with both CLs was significantly lower compared to the value without CLs (t test; p<0.001) but no significant difference was found between the two powers of CLs. Rebound tonometry over positive hydrogel CLs leads to a certain degree of IOP underestimation. This result did not change for the two positive lenses used in the experiment, despite their large difference in power and therefore in lens thickness. Optometrists should bear this in mind when measuring IOP with the rebound tonometer over plus power contact lenses. Copyright © 2016 The Authors. Published by Elsevier Espana.. All rights reserved.
Ogbuehi, Kelechi C
2012-06-01
To quantify the influence of soft contact lens power and thickness on the intraocular pressure (IOP). Thirty-nine young, healthy adult volunteers completed this study. One eye of each subject was randomly assigned either a +6D or a -6D high water content daily disposable lens. The other eye was fitted with the second lens. Triplicate measurements of IOP were taken before, during, and after contact lens wear. Each time, IOP was assessed in a randomized order with two noncontact tonometers. The lenses were swapped between eyes during a second session of measurements, one week later. In the first session with the +6D lenses, the average IOPs (±SDs) before, with the lenses fitted, and after the lenses were removed, were: 14.3 ± 2.9 mmHg, 17.0 ± 3.3 mmHg and 13.9 ± 3.1 mmHg, respectively, for the CT80 and 13.6 ± 3.1 mmHg, 17.1 ± 4.5 mmHg and 13.3 ± 2.9 mmHg, respectively, for the PT100. The corresponding values for the first session with the -6D lenses were: 14.3 ± 3.1 mmHg, 13.1 ± 3.1 mmHg and 14.1 ± 3.3 mmHg, respectively, for the CT80 and 13.6 ± 3.2 mmHg, 13.0 ± 3.0 mmHg and 13.6 ± 3.2 mmHg, respectively, for the PT100. IOP significantly (P<0.05) increased (+ΔIOP=2.7 ± 0.4 mmHg with the CT80 in the first session) with the +6D lenses, but decreased (P<0.05) when the -6D lenses were fitted (-ΔIOP=0.6 ± 0.2 mmHg with the PT100 in the first session). The soft contact lens-induced changes were consistent between sessions but varied between tonometers. The measurement of IOP through soft contact lenses resulted in consistent, statistically significant differences in IOP, which were not uniform across tonometers and which did not appear to be solely related to the central thickness of the soft contact lenses. Copyright © 2012 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Schor, Clifton M; Bharadwaj, Shrikant R; Burns, Christopher D
2007-07-01
A dynamic model of ocular accommodation is used to simulate the stability and dynamic performance of accommodating intraocular lenses (A-IOLs) that replace the hardened natural ocular lens that is unable to change focus. Accommodation simulations of an older eye with A-IOL materials having biomechanical properties of a younger eye illustrate overshoots and oscillations resulting from decreased visco-elasticity of the A-IOL. Stable dynamics of an A-IOL are restored by adaptation of phasic and tonic neural-control properties of accommodation. Simulations indicate that neural control must be recalibrated to avoid unstable dynamic accommodation with A-IOLs. An interactive web-model of A-IOL illustrating these properties is available at http://schorlab.berkeley.edu.
NASA Astrophysics Data System (ADS)
Reutterer, Bernd; Traxler, Lukas; Bayer, Natascha; Drauschke, Andreas
2017-04-01
To evaluate the performance of intraocular lenses to treat cataract, an optomechanical eye model was developed. One of the most crucial components is the IOL holder, which should guarantee a physiological representation of the capsular bag and a stable position during measurement sequences. Individual holders are required due to the fact that every IOL has different geometric parameters. A method which allows obtaining the correct dimensions for the holder of a special IOL was developed and tested, by verifying the position of the IOL before and after a measurement sequence. Results of telecentric measurements and MTF measurements show that the IOL position does not change during the displacement sequence induced by the stepper motors of the eye model.
Spectral properties of common intraocular lens (IOL) types
NASA Astrophysics Data System (ADS)
Milne, Peter J.; Chapon, Pascal F.; Hamaoui, Marie; Parel, Jean-Marie A.; Clayman, H.; Rol, Pascal O.
1999-06-01
Currently over 50 kinds of intraocular lenses (IOLs) are approved for patient use in the treatment of cataracts and ametropia. These lenses are manufactured from at least 2 kinds of silicones as well as several kinds of acrylic polymers including polyHEMA, Poly HOXEMA, a range of polymethacrylate and polyacrylate formulations. We sought to measure spectral transmission curves of a range of IOLS in the UV-visible and near IR spectral regions in order to better characterize their optical properties and to provide a baseline from which to assess their alteration following implantation over time. Consideration of how this may best be achieved are discussed. The variable ability of both explained IOLs and some samples from a range of manufacturers to block UV wavelengths is commented upon.
Major ocular trauma in Taiwan: 2002-2004 versus 2012-2014.
Chang, Yi-Sheng; Teng, Yu-Ti; Huang, Yi-Hsun; Liu, Mei-Ling; Hung, Jia-Horung; Hsu, Sheng-Min; Huang, Fu-Chin; Shih, Min-Hsiu; Chen, Wan-Ju; Lai, Chun-Chieh; Hsiao, Shu-Fang; Wang, Shih-Hao; Tseng, Sung-Huei
2018-05-04
We investigated the temporal changes in major eye injuries in Taiwan by reviewing the medical records of all patients with ocular trauma hospitalized at the National Cheng Kung University Hospital during 2002-2004 and 2012-2014. A total of 169 eyes (161 patients) during 2002-2004 and 121 eyes (120 patients) during 2012-2014 were enrolled (mean ± SD age: 41.9 ± 20.8 years in 2002-2004, and 51.8 ± 19.3 years in 2012-2014). Males accounted for ~75% of patients. The most frequent injury-causing object was metallic material (~24%), and blunt traumas were most frequently attributable to traffic accidents and falls. The most common locations of injuries for males and females were the workplace and home, respectively. Open-globe injuries occurred in ~70% of eyes, requiring primary repair, cataract extraction, and/or intraocular lens implantation. The frequencies of fall injury, lacrimal system laceration, lens injury, corneal/scleral foreign bodies, and use of intracameral antibiotics increased from 2002-2004 to 2012-2014, while those of closed-globe injury, vitreous haemorrhage, optic nerve injury, and medical treatment decreased. The final visual acuity remained poor (≤20/200) in >1/3 of injured eyes. Despite therapeutic advancements, major eye injuries still pose a high risk for poor visual outcome.
Personalized pseudophakic model
NASA Astrophysics Data System (ADS)
Ribeiro, F.; Castanheira-Dinis, A.; Dias, J. M.
2014-08-01
With the aim of taking into account all optical aberrations, a personalized pseudophakic optical model was designed for refractive evaluation using ray tracing software. Starting with a generic model, all clinically measurable data were replaced by personalized measurements. Data from corneal anterior and posterior surfaces were imported from a grid of elevation data obtained by topography, and a formula for the calculation of the intraocular lens (IOL) position was developed based on the lens equator. For the assessment of refractive error, a merit function minimized by the approximation of the Modulation Transfer Function values to diffraction limit values on the frequencies corresponding up to the discrimination limits of the human eye, weighted depending on the human contrast sensitivity function, was built. The model was tested on the refractive evaluation of 50 pseudophakic eyes. The developed model shows good correlation with subjective evaluation of a pseudophakic population, having the added advantage of being independent of corrective factors, allowing it to be immediately adaptable to new technological developments. In conclusion, this personalized model, which uses individual biometric values, allows for a precise refractive assessment and is a valuable tool for an accurate IOL power calculation, including in conditions to which population averages and the commonly used regression correction factors do not apply, thus achieving the goal of being both personalized and universally applicable.
Rahimy, E; Wilson, J; Tsao, T-C; Schwartz, S; Hubschman, J-P
2013-01-01
Purpose The aim of this study is to develop a novel robotic surgical platform, the IRISS (Intraocular Robotic Interventional and Surgical System), capable of performing both anterior and posterior segment intraocular surgery, and assess its performance in terms of range of motion, speed of motion, accuracy, and overall capacities. Patients and methods To test the feasibility of performing ‘bimanual' intraocular surgical tasks using the IRISS, we defined four steps out of typical anterior (phacoemulsification) and posterior (pars plana vitrectomy (PPV)) segment surgery. Selected phacoemulsification steps included construction of a continuous curvilinear capsulorhexis and cortex removal in infusion–aspiration (I/A) mode. Vitrectomy steps consisted of performing a core PPV, followed by aspiration of the posterior hyaloid with the vitreous cutter to induce a posterior vitreous detachment (PVD) assisted with triamcinolone, and simulation of the microcannulation of a temporal retinal vein. For each evaluation, the duration and the successful completion of the task with or without complications or involuntary events was assessed. Results Intraocular procedures were successfully performed on 16 porcine eyes. Four eyes underwent creation of a round, curvilinear anterior capsulorhexis without radialization. Four eyes had I/A of lens cortical material completed without posterior capsular tear. Four eyes completed 23-gauge PPV followed by successful PVD induction without any complications. Finally, simulation of microcannulation of a temporal retinal vein was successfully achieved in four eyes without any retinal tears/perforations noted. Conclusion Robotic-assisted intraocular surgery with the IRISS may be technically feasible in humans. Further studies are pending to improve this particular surgical platform. PMID:23722720
Marcos, Susana; Rosales, Patricia; Llorente, Lourdes; Barbero, Sergio; Jiménez-Alfaro, I
2008-01-01
It is well known that the aberrations of the cornea are partially compensated by the aberrations of the internal optics of the eye (primarily the crystalline lens) in young subjects. This effect has been found not only for the spherical aberration, but also for horizontal coma. It has been debated whether the compensation of horizontal coma is the result of passive mechanism [Artal, P., Benito, A., & Tabernero, J. (2006). The human eye is an example of robust optical design. Journal of Vision, 6 (1), 1-7] or through an active developmental feedback process [Kelly, J. E., Mihashi, T., & Howland, H. C. (2004). Compensation of corneal horizontal/vertical astigmatism, lateral coma, and spherical aberration by internal optics of the eye. Journal of Vision, 4 (4), 262-271]. In this study we investigate the active or passive nature of the horizontal coma compensation using eyes with artificial lenses, where no active developmental process can be present. We measured total and corneal aberrations, and lens tilt and decentration in a group of 38 eyes implanted with two types of intraocular lenses designed to compensate the corneal spherical aberration of the average population. We found that spherical aberration was compensated by 66%, and horizontal coma by 87% on average. The spherical aberration is not compensated at an individual level, but horizontal coma is compensated individually (coefficients of correlation corneal/internal aberration: -0.946, p<0.0001). The fact that corneal (but not total) horizontal coma is highly correlated with angle lamda (computed from the shift of the 1st Purkinje image from the pupil center, for foveal fixation) indicates that the compensation arises primarily from the geometrical configuration of the eye (which generates horizontal coma of opposite signs in the cornea and internal optics). The amount and direction of tilts and misalignments of the lens are comparable to those found in young eyes, and on average tend to compensate (rather than increase) horizontal coma. Computer simulations using customized model eyes and different designs of intraocular lenses show that, while not all designs produce a compensation of horizontal coma, a wide range of aspheric biconvex designs may produce comparable compensation to that found in young eyes with crystalline lenses, over a relatively large field of view. These findings suggest that the lens shape, gradient index or foveal location do not need to be fine-tuned to achieve a compensation of horizontal coma. Our results cannot exclude a fine-tuning for the orientation of the crystalline lens, since cataract surgery seems to preserve the position of the capsule.
Koolwijk, Jasper; Fick, Mark; Selles, Caroline; Turgut, Gökhan; Noordergraaf, Jeske I M; Tukkers, Floor S; Noordergraaf, Gerrit J
2015-02-01
To evaluate whether an ophthalmologist-led, non-anesthesia-supported, limited monitoring pathway for phacoemulsification/intraocular lens cataract surgery, can be performed safely with only a medical emergency team providing support. Retrospective, observational, cohort study. All patients who underwent elective phacoemulsification/intraocular lens surgery under topical anesthesia in the ophthalmology outpatient unit between January 1, 2011, and December 31, 2012. Cataract surgery was performed by phacoemulsification under topical anesthesia. The intake process mainly embraced ophthalmic evaluation, obtaining a medical history, and proposing the procedure. A staff ophthalmologist performed the procedure assisted by 2 registered nurses in an independent outpatient clinic operating room within the hospital. The clinical pathway was without dedicated presence of or access to anesthesia service. Perioperative monitoring was limited to blood pressure and plethysmography preoperatively and intraoperatively. Patients were offered supportive care and instructed to avoid fasting and continue all their chronic medication. The primary outcome measure was the incidence of adverse events requiring medical emergency team (MET) interventions throughout the pathway. Secondary outcome measures were surgical ocular complication rates, use of oral sedatives, and reported reasons to perform the surgery in the classical operation room complex. Within the cataract pathway, 6961 cases (4347 patients) were eligible for analysis. Three MET interventions related to the phacoemulsification/intraocular lens pathway occurred in the 2-year study period, resulting in an intervention rate of 0.04%. None of the interventions was intraoperative. All 3 patients were diagnosed as vasovagal collapse and recuperated uneventfully. No hospital admittance was required. Eight other incidents occurred within the general ophthalmology outpatient unit population during the study period. Cataract surgery can be safely performed in an outpatient clinic, in the absence of the anesthesia service and with limited workup and monitoring. Basic first aid and basic life support skills seem to be sufficient in case of an adverse event. An MET provides a generous failsafe for this low-risk procedure. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Lee, Shinwook; Choi, Myoung; Xu, Zaiwei; Zhao, Zeyu; Alexander, Elsinore; Liu, Yueai
2016-01-01
Purpose The purpose of this study is to compare the optical characteristics of the novel PanOptix presbyopia-correcting trifocal intraocular lens (IOL) and the multifocal ReSTOR +3.0 D IOL, through in vitro bench investigations. Methods The optical characteristics of AcrySof® IQ PanOptix™ (PanOptix) and AcrySof® IQ ReSTOR +3.0 D (ReSTOR +3.0 D) IOLs were evaluated by through-focus Badal images, simulated headlight images, and modulation transfer function (MTF) measurements which determine resolution, photic phenomena, and image quality. Through-focus Badal images of an Early Treatment of Diabetic Retinopathy Study chart were recorded at both photopic and mesopic pupil sizes. Simulated headlight images were taken on an MTF bench with a 50-μm pinhole target and a 5.0 mm pupil at the distance focus of the IOL. MTF curves were measured with a 3.0 mm pupil, and spatial frequencies equivalent to 20/40 and 20/20 visual acuities were recorded to illustrate the through-focus MTF curves. Far-, intermediate-, and near-focus MTF values were obtained. Results Bench Badal image testing and MTF measurements showed that PanOptix has a near focus at a distance of 42 cm and an additional intermediate focus at a distance of about 60 cm. The near focus for ReSTOR +3.0 D is at 45 cm. PanOptix and ReSTOR +3.0 D have comparable photopic distances and near MTF values. Additionally, PanOptix provided a substantial continuous range of vision from distance to intermediate and to near compared with ReSTOR +3.0 D. The halo propensity for PanOptix was slightly higher than that for ReSTOR +3.0 D. Conclusion Laboratory-based in vitro simulations showed that PanOptix trifocal IOL has comparable resolution and image quality performance in distance and near foci compared with ReSTOR +3.0 D IOL. PanOptix showed better resolution and image quality performance at the intermediate focus than ReSTOR +3.0 D IOL. PMID:27330273
Karunaratne, Nicholas
2013-12-01
To compare the accuracy of the Pentacam Holladay equivalent keratometry readings with the IOL Master 500 keratometry in calculating intraocular lens power. Non-randomized, prospective clinical study conducted in private practice. Forty-five consecutive normal patients undergoing cataract surgery. Forty-five consecutive patients had Pentacam equivalent keratometry readings at the 2-, 3 and 4.5-mm corneal zone and IOL Master keratometry measurements prior to cataract surgery. For each Pentacam equivalent keratometry reading zone and IOL Master measurement the difference between the observed and expected refractive error was calculated using the Holladay 2 and Sanders, Retzlaff and Kraff theoretic (SRKT) formulas. Mean keratometric value and mean absolute refractive error. There was a statistically significantly difference between the mean keratometric values of the IOL Master, Pentacam equivalent keratometry reading 2-, 3- and 4.5-mm measurements (P < 0.0001, analysis of variance). There was no statistically significant difference between the mean absolute refraction error for the IOL Master and equivalent keratometry readings 2 mm, 3 mm and 4.5 mm zones for either the Holladay 2 formula (P = 0.14) or SRKT formula (P = 0.47). The lowest mean absolute refraction error for Holladay 2 equivalent keratometry reading was the 4.5 mm zone (mean 0.25 D ± 0.17 D). The lowest mean absolute refraction error for SRKT equivalent keratometry reading was the 4.5 mm zone (mean 0.25 D ± 0.19 D). Comparing the absolute refraction error of IOL Master and Pentacam equivalent keratometry reading, best agreement was with Holladay 2 and equivalent keratometry reading 4.5 mm, with mean of the difference of 0.02 D and 95% limits of agreement of -0.35 and 0.39 D. The IOL Master keratometry and Pentacam equivalent keratometry reading were not equivalent when used only for corneal power measurements. However, the keratometry measurements of the IOL Master and Pentacam equivalent keratometry reading 4.5 mm may be similarly effective when used in intraocular lens power calculation formulas, following constant optimization. © 2013 Royal Australian and New Zealand College of Ophthalmologists.
The effect of the timing of the cessation of contact lens use on the results of biometry.
Goudie, Colin; Tatham, Andrew; Davies, Rhys; Sifton, Alison; Wright, Mark
2018-06-01
Current guidelines vary regarding when to remove contact lenses prior to performing biometry, and there is no clear evidence behind these guidelines. This study aimed to determine the effect of soft contact lens wear on biometric measurements by examining the change in predicted lens power for emmetropia at several time points following removal of soft contact lenses. A prospective, controlled study of healthy soft contact lens wearers. Biometry was performed immediately after removing contact lenses and then after 2, 4 and 7 days of no contact lens use. Healthy non-contact lens wearers were used as controls. All measurements were taken with the Zeiss IOLMaster. In all, 14 subjects and 13 controls were recruited. There was no significant difference in age or gender between groups. Eight of the fourteen subjects wore daily disposable CLs, two wore 2-weekly and four wore monthly soft CLs. Measurements from controls and contact lens-wearing subjects showed similar degrees of variation over time. The within-subject SD in predicted intraocular lens (IOL) power for emmetropia for contact lens wearers was 0.20 D (95% CI 0.16-0.25 D) compared to 0.18 D (95% CI 0.12-0.26 D) for controls. There is a significant variation in UK practice regarding advice on the timing of cessation of contact lens wear prior to having biometry performed. Our study suggests that it is likely that soft contact lens wearers are currently being advised to remove their contact lenses for an unnecessarily long period of time prior to having biometry performed.
[Preservatives in ophthalmology].
Messmer, E M
2012-11-01
Preservatives are a legal requirement for eye drops in multidose containers. Moreover, they are necessary for stabilization and intraocular penetration for a number of ophthalmic preparations. Most preservatives act in a relatively unspecific manner as detergents or by oxidative mechanisms and thereby cause side effects at the ocular surface. They may also affect the lens, trabecular meshwork and the retina. Benzalkonium chloride is the most commonly used preservative in ophthalmology and is more toxic than other or newer preservatives, such as polyquaternium-1 (Polyquad), sodium perborate, oxychloro-complex (Purite®) and SofZia. Preservative-free topical medication is highly recommended for patients with ocular surface disease, frequent eye drop administration, proven allergy to preservatives and contact lens wear.
Extralenticular and lenticular aspects of accommodation and presbyopia in human versus monkey eyes.
Croft, Mary Ann; McDonald, Jared P; Katz, Alexander; Lin, Ting-Li; Lütjen-Drecoll, Elke; Kaufman, Paul L
2013-07-26
To determine if the accommodative forward movements of the vitreous zonule and lens equator occur in the human eye, as they do in the rhesus monkey eye; to investigate the connection between the vitreous zonule posterior insertion zone and the posterior lens equator; and to determine which components-muscle apex width, lens thickness, lens equator position, vitreous zonule, circumlental space, and/or other intraocular dimensions, including those stated in the objectives above-are most important in predicting accommodative amplitude and presbyopia. Accommodation was induced pharmacologically in 12 visually normal human subjects (ages 19-65 years) and by midbrain electrical stimulation in 11 rhesus monkeys (ages 6-27 years). Ultrasound biomicroscopy imaged the entire ciliary body, anterior and posterior lens surfaces, and the zonule. Relevant distances were measured in the resting and accommodated eyes. Stepwise regression analysis determined which variables were the most important predictors. The human vitreous zonule and lens equator move forward (anteriorly) during accommodation, and their movements decline with age, as in the monkey. Over all ages studied, age could explain accommodative amplitude, but not as well as accommodative lens thickening and resting muscle apex thickness did together. Accommodative change in distances between the vitreous zonule insertion zone and the posterior lens equator or muscle apex were important for predicting accommodative lens thickening. Our findings quantify the movements of the zonule and ciliary muscle during accommodation, and identify their age-related changes that could impact the optical change that occurs during accommodation and IOL function.
Nekolova, Jana; Rozsival, Pavel; Sin, Martin; Jiraskova, Nada
2017-06-01
To present the initial results of Scharioth Macula Lens (SML) implantation. The SML is a new add-on intraocular lens designed to increase uncorrected near visual acuity (UCVA) in patients with stabilized maculopathy. Eight patients were included in the study. All met the indication criteria before SML implantation. An SML was implanted in the better seeing eye. Near and distance visual acuity were tested. Possible complications and patient complaints were recorded and patients were asked about their quality of vision after SML implantation. The examination was carried out on day 1, 1 week, 1, 3 and 6 months after surgery. Six-month-results are presented. Apart from one, all patients with the SML had good near visual acuity at a recommended reading distance of 15 cm. Preoperatively, the mean (min-max) near UCVA was J13 (J8-J16), mean distance BCVA was 0.27. Postoperatively, the best results were after 1 month - near UCVA was J2.5 (J1-J7), distance BCVA was 0.26. Three months after surgery, this decreased to J4.5 (J1-J8); distance VA remained 0.25. Six months postoperatively - near vision was J4 (J1-J8) and distance VA was unchanged. Patients reported problems with reading speed and reading distance. Daily exercise improved their reading ability. One patient converted to wet AMD 3 months post-implantation. The SML is a new hope for low-vision patients. It acts as a magnifier in the eye. It is a suitable method for increasing near visual acuity in patients with inactive maculopathy.
Rosen, Emanuel; Alió, Jorge L; Dick, H Burkhard; Dell, Steven; Slade, Stephen
2016-02-01
We performed a metaanaysis of peer-reviewed studies involving implantation of a multifocal intraocular lens (IOL) in presbyopic patients with cataract or having refractive lens exchange (RLE). Previous reviews have considered the use of multifocal IOLs after cataract surgery but not after RLE, whereas greater insight might be gained from examining the full range of studies. Selected studies were examined to collate outcomes with monocular and binocular uncorrected distance, intermediate, and near visual acuity; spectacle independence; contrast sensitivity; visual symptoms; adverse events; and patient satisfaction. In 8797 eyes, the mean postoperative monocular uncorrected distance visual acuity (UDVA) was 0.05 logMAR ± 0.006 (SD) (Snellen equivalent 20/20(-3)). In 6334 patients, the mean binocular UDVA was 0.04 ± 0.00 logMAR (Snellen equivalent 20/20(-2)), with a mean spectacle independence of 80.1%. Monocular mean UDVA did not differ significantly between those who had a cataract procedure and those who had an RLE procedure. Neural adaptation to multifocality may vary among patients. Dr. Alió is a clinical research investigator for Hanita Lenses, Carl Zeiss Meditec AG, Topcon Medical Systems, Inc., Oculentis GmbH, and Akkolens International BV. Dr. Dell is a consultant to Bausch & Lomb and Abbott Medical Optics, Inc. Dr. Slade is a consultant to Alcon Surgical, Inc., Carl Zeiss Meditec AG, and Bausch & Lomb. None of the authors has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Huang, Yi-Shiang; Bertrand, Virginie; Bozukova, Dimitriya; Pagnoulle, Christophe; Labrugère, Christine; De Pauw, Edwin; De Pauw-Gillet, Marie-Claire; Durrieu, Marie-Christine
2014-01-01
Posterior Capsular Opacification (PCO) is the capsule fibrosis developed on implanted IntraOcular Lens (IOL) by the de-differentiation of Lens Epithelial Cells (LECs) undergoing Epithelial Mesenchymal Transition (EMT). Literature has shown that the incidence of PCO is multifactorial including the patient's age or disease, surgical technique, and IOL design and material. Reports comparing hydrophilic and hydrophobic acrylic IOLs have shown that the former has more severe PCO. On the other hand, we have previously demonstrated that the adhesion of LECs is favored on hydrophobic compared to hydrophilic materials. By combining these two facts and contemporary knowledge in PCO development via the EMT pathway, we propose a biomimetically inspired strategy to promote LEC adhesion without de-differentiation to reduce the risk of PCO development. By surface grafting of a cell adhesion molecule (RGD peptide) onto the conventional hydrophilic acrylic IOL material, the surface-functionalized IOL can be used to reconstitute a capsule-LEC-IOL sandwich structure, which has been considered to prevent PCO formation in literature. Our results show that the innovative biomaterial improves LEC adhesion, while also exhibiting similar optical (light transmittance, optical bench) and mechanical (haptic compression force, IOL injection force) properties compared to the starting material. In addition, compared to the hydrophobic IOL material, our bioactive biomaterial exhibits similar abilities in LEC adhesion, morphology maintenance, and EMT biomarker expression, which is the crucial pathway to induce PCO. The in vitro assays suggest that this biomaterial has the potential to reduce the risk factor of PCO development. PMID:25501012
Huang, Yi-Shiang; Bertrand, Virginie; Bozukova, Dimitriya; Pagnoulle, Christophe; Labrugère, Christine; De Pauw, Edwin; De Pauw-Gillet, Marie-Claire; Durrieu, Marie-Christine
2014-01-01
Posterior Capsular Opacification (PCO) is the capsule fibrosis developed on implanted IntraOcular Lens (IOL) by the de-differentiation of Lens Epithelial Cells (LECs) undergoing Epithelial Mesenchymal Transition (EMT). Literature has shown that the incidence of PCO is multifactorial including the patient's age or disease, surgical technique, and IOL design and material. Reports comparing hydrophilic and hydrophobic acrylic IOLs have shown that the former has more severe PCO. On the other hand, we have previously demonstrated that the adhesion of LECs is favored on hydrophobic compared to hydrophilic materials. By combining these two facts and contemporary knowledge in PCO development via the EMT pathway, we propose a biomimetically inspired strategy to promote LEC adhesion without de-differentiation to reduce the risk of PCO development. By surface grafting of a cell adhesion molecule (RGD peptide) onto the conventional hydrophilic acrylic IOL material, the surface-functionalized IOL can be used to reconstitute a capsule-LEC-IOL sandwich structure, which has been considered to prevent PCO formation in literature. Our results show that the innovative biomaterial improves LEC adhesion, while also exhibiting similar optical (light transmittance, optical bench) and mechanical (haptic compression force, IOL injection force) properties compared to the starting material. In addition, compared to the hydrophobic IOL material, our bioactive biomaterial exhibits similar abilities in LEC adhesion, morphology maintenance, and EMT biomarker expression, which is the crucial pathway to induce PCO. The in vitro assays suggest that this biomaterial has the potential to reduce the risk factor of PCO development.
Khan, A O; AlGaeed, A
2006-12-01
To compare the following two methods of paediatric secondary posterior chamber intraocular lens (PCIOL) determination with the Holladay formula: (1) estimation from the aphakic refraction alone (using assumed keratometry (K) of 44 diopters); and (2) calculation based on preoperative measured biometry. (1) Retrospective medical record review in a referral eye hospital of children with aphakia aged < or =12 years who underwent secondary PCIOL implantation with an Alcon MA60BM lens; (2) PCIOL determination for a plano refraction by the above two methods (estimation and calculation); and (3) prediction of pseudophakic refraction for the PCIOL actually implanted by the above two methods compared with the actual pseudophakic refraction. 50 eyes of 30 children with aphakia were studied. The estimated (mean, 95% confidence interval (CI)) secondary PCIOL values (25.81, +/-1.65 D) and the calculated secondary PCIOL values (26.35, +/-1.50 D) were not significantly different (mean absolute value of the difference 1.86 D, 95% CI +/-0.41 D) by the two-tailed paired t test at alpha = 0.05 (p = 0.11). For each eye, the pseudophakic refractions predicted by the two methods for the PCIOL that was actually implanted differed, both from each other and from the actual pseudophakic refraction (repeated-measures analysis of variance, p<0.001; Tukey test, p<0.01). The method of PCIOL estimation from the aphakic refraction alone provides values similar to those obtained by a standard technique and can be useful if biometry is unavailable. Targeting a pseudophakic refraction in paediatric aphakia is prone to error.
Zhao, Huawei
2009-01-01
A ZEMAX model was constructed to simulate a clinical trial of intraocular lenses (IOLs) based on a clinically oriented Monte Carlo ensemble analysis using postoperative ocular parameters. The purpose of this model is to test the feasibility of streamlining and optimizing both the design process and the clinical testing of IOLs. This optical ensemble analysis (OEA) is also validated. Simulated pseudophakic eyes were generated by using the tolerancing and programming features of ZEMAX optical design software. OEA methodology was verified by demonstrating that the results of clinical performance simulations were consistent with previously published clinical performance data using the same types of IOLs. From these results we conclude that the OEA method can objectively simulate the potential clinical trial performance of IOLs.
Repair of a ruptured globe using topical anesthesia.
Auffarth, Gerd U; Vargas, Luis G; Klett, Jens; Völcker, Hans E
2004-03-01
We present a 76-year-old patient who had ocular trauma with dehiscence of the wound and scleral rupture with a prolapsed iris, ciliary body, intraocular lens, and vitreous after uneventful cataract surgery with a self-sealing sclerocorneal tunnel incision. General anesthesia was not possible because the patient had a history of lung cancer with extensive emphysema and unstable coronary disease. Local retrobulbar or peribulbar anesthesia was not considered because of the risk for further extrusion of intraocular contents. Topical anesthesia was applied with a 10.0 mm x 2.5 mm cellulose sponge soaked in oxybuprocaine 0.4% (Novesine) placed under the upper and lower lid for 20 minutes. Surgical repair of a 14.0 mm scleral wound was achieved without complication or pain during the procedure.
Ocular and orbital porcupine quills in the dog: a review and case series.
Grahn, B H; Szentimrey, D; Pharr, J W; Farrow, C S; Fowler, D
1995-01-01
A retrospective evaluation of 5 cases of orbital or intraocular porcupine quills in the dog and a literature review from MEDLINE (1983-1995) is presented. This paper reviews the diagnosis, therapy, and visual prognosis of ocular and orbital quills in the dog. Distinguishing penetration and perforation of the eye and intraocular structures is paramount in establishing a visual prognosis and appropriate therapy. Perforation of the cornea or sclera, lens, or the uvea and retina necessitates prompt specialized surgical therapy to save vision. The diagnosis of orbital quills can be readily confirmed with ultrasonography. The characteristic sonographic appearance of a double-banded, linear, hyperechoic object allows accurate localization of the quill, which aids surgical removal. Images Figure 1. Figure 2. Figure 3. Figure 4. Figure 5. Figure 6. PMID:7585434
Immersion ultrasonography: simultaneous A-scan and B-scan.
Coleman, D J; Dallow, R L; Smith, M E
1979-01-01
In eyes with opaque media, ophthalmic ultrasound provides a unique source of information that can dramatically affect the course of patient management. In addition, when an ocular abnormality can be visualized, ultrasonography provides information that supplements and complements other diagnostic testing. It provides documentation and differentiation of abnormal states, such as vitreous hemorrhage and intraocular tumor, as well as differentiation of orbital tumors from inflammatory causes of exophthalmos. Additional capabilities of ultrasound are biometric determinations for calculation of intraocular lens implant powers and drug-effectiveness studies. Maximal information is derived from ultrasonography when A-scan and B-scan techniques are employed simultaneously. Flexibility of electronics, variable-frequency transducers, and the use of several different manual scanning patterns aid in detection and interpretation of results. The immersion system of ultrasonography provides these features optimally.
Rabie, Hossein Mohammad; Esfandiari, Hamed; Rikhtegar, Mohammad Hassan; Hekmat, Vahid
2018-02-01
To describe our experience with exchanging sulcus-fixated single-piece intraocular lens (IOL) with 3-piece IOLs for management of pigmentary glaucoma. In this retrospective study, records of patients who underwent sulcus-fixated single-piece IOL exchanged with 3-piece IOLs were retrieved, and demographic and baseline data of patients, type of IOL, pre- and post-IOL exchange BCVA, IOP, number of anti-glaucoma medications, and optic nerve head examination were documented. Baseline and final examinations were analyzed and compared. Mean age of the patients was 59 ± 10 years, and 5 (41.6%) were female. Mean interval between primary cataract extraction operation and IOL exchange was 17 ± 5 months. Nine patients received in sulcus implantation of Alcon SA60AT, and three patients had SN60WF model at the end of primary surgery. BCVA changed insignificantly from 0.06 ± 0.06 logMAR to 0.06 ± 0.06 after IOL exchange. (P = 0.22) IOP was controlled in 8 cases (66.6%), but four cases (33.3%) needed glaucoma surgery to further control glaucoma condition. IOP decreased significantly from preoperative 17 ± 3 to 14 ± 1 mmHg postoperatively. Patients with advanced age and higher baseline IOP were more likely to undergo glaucoma surgery after IOL exchange. (P = 0.07 and 0.00, respectively). single-piece IOL exchange with 3-piece IOL dramatically decreases pigment release and reduces IOP. Those with advanced age and higher IOP are less likely to respond to IOL exchange and may need glaucoma surgery to control high intraocular pressure.
Traverso, Carlo Enrico; Cutolo, Carlo Alberto
2017-08-01
To investigate the clinical, anatomical, and patient-reported outcomes of phacoemulsification (PE) with intraocular lens implantation performed to treat primary angle closure (PAC) and primary angle-closure glaucoma (PACG). Patients were evaluated at baseline and at 6 months after PE. The examination included visual acuity, intraocular pressure (IOP), visual field, optic nerve head, endothelial cell count (ECC), aqueous depth, and ocular biometric parameters. Patient-reported visual function and health status were assessed. Coprimary outcome measures were IOP changes, angle widening, and patient-reported visual function; secondary outcome measures were visual acuity changes, use of IOP-lowering medications, and complications. Univariate and multivariate analyses were performed to determine the predictors of IOP change. Thirty-nine cases were identified, and postoperative data were analyzed for 59 eyes, 39 with PACG and 20 with PAC. Globally, PE resulted in a mean reduction in IOP of -6.33 mm Hg (95% CI, -8.64 to -4.01, P <.001). Aqueous depth and angle measurements improved ( P <.01), whereas ECC significantly decreased ( P <.001). Both corrected and uncorrected visual acuity improved ( P <.01). The EQ visual analog scale did not change ( P =.16), but VFQ-25 improved ( P <.01). The IOP-lowering effect of PE was greater in the PACG compared to the PAC group ( P =.04). In both groups, preoperative IOP was the most significant predictor of IOP change ( P <.01). No sight-threatening complications were recorded. Our data support the usefulness of PE in lowering the IOP in patients with PAC and PACG. Although PE resulted in several anatomical and patient-reported visual improvements, we observe that a marked decrease in ECC should be carefully weighed before surgery.
Combining zonal refractive and diffractive aspheric multifocal intraocular lenses.
Muñoz, Gonzalo; Albarrán-Diego, César; Javaloy, Jaime; Sakla, Hani F; Cerviño, Alejandro
2012-03-01
To assess visual performance with the combination of a zonal refractive aspheric multifocal intraocular lens (MIOL) (Lentis Mplus, Oculentis GmbH) and a diffractive aspheric MIOL (Acri.Lisa 366, Acri.Tech GmbH). This prospective interventional cohort study comprised 80 eyes from 40 cataract patients (mean age: 65.5±7.3 years) who underwent implantation of the Lentis Mplus MIOL in one eye and Acri.Lisa 366 MIOL in the fellow eye. The main outcome measures were refraction; monocular and binocular uncorrected and corrected distance, intermediate, and near visual acuities; monocular and binocular defocus curves; binocular photopic contrast sensitivity function compared to a monofocal intraocular lens (IOL) control group (40 age-matched pseudophakic patients implanted with the AR-40e [Abbott Medical Optics]); and quality of vision questionnaire. Binocular uncorrected visual acuities were 0.12 logMAR (0.76 decimal) or better at all distances measured between 6 m and 33 cm. The Lentis Mplus provided statistically significant better vision than the Acri.Lisa at distances between 2 m and 40 cm, and the Acri.Lisa provided statistically significant better vision than the Lentis Mplus at 33 cm. Binocular defocus curve showed little drop-off at intermediate distances. Photopic contrast sensitivity function for distance and near were similar to the monofocal IOL control group except for higher frequencies. Moderate glare (15%), night vision problems (12.5%), and halos (10%) were reported. Complete independence of spectacles was achieved by 92.5% of patients. The combination of zonal refractive aspheric and diffractive aspheric MIOLs resulted in excellent uncorrected binocular distance, intermediate, and near vision, with low incidence of significant photic phenomena and high patient satisfaction. Copyright 2012, SLACK Incorporated.
Hayashi, Ken; Ogawa, Soichiro; Manabe, Shin-Ichi; Hirata, Akira; Yoshimura, Koichi
2016-03-01
The aim of this study was to examine the recent status of intraocular lens (IOL) dislocation according to a classification system based on vertical dislocation position, as well as the surgical techniques and outcomes of IOL exchange surgery. The medical records of 230 eyes from 214 consecutive patients who experienced IOL dislocation and underwent exchange surgery between 2006 and 2014 were reviewed. Vertical dislocation sites observed preoperatively under operating microscopy were examined, along with the surgical techniques and outcomes of IOL exchange. Dislocation sites included (1) the anterior chamber (12.2 %), (2) pseudophakodonesis (19.1 %), (3) the anterior vitreous cavity (47.4 %), (4) trap door-like dislocation (dangling in the peripheral vitreous cavity; 16.1 %), and (5) the retinal surface (5.2 %). The IOL retained in the anterior segment was moved onto the iris by pulling it up through the limbal side ports with an anterior vitrectomy (67.8 %), or by pushing it up from the pars plana with an anterior vitrectomy (26.5 %), while the IOL dropped on the retina was lifting it up from the retina after pars plana vitrectomy (5.7 %). Mean uncorrected and distance-corrected visual acuity significantly improved postoperatively (p < 0.0001). Major complications included a marked elevation in intraocular pressure (7.8 %), pupillary capture (6.5 %), and vitreous hemorrhage (2.6 %). Based on the classification system, approximately 95 % of dislocated IOLs were retained in the anterior segment, and these IOLs were exchanged using an anterior approach through limbal incisions with an anterior vitrectomy. Visual acuity improved significantly, and serious complications were uncommon, probably because the IOL exchange techniques were standardized and simplified without pars plana vitrectomy.
Ramón, María L; Piñero, David P; Pérez-Cambrodí, Rafael J
2012-02-01
To examine the visual performance of a rotationally asymmetric multifocal intraocular lens (IOL) by correlating the defocus curve of the IOL-implanted eye with the intraocular aberrometric profile and impact on the quality of life. A prospective, consecutive, case series study including 26 eyes from 13 patients aged between 50 and 83 years (mean: 65.54±7.59 years) was conducted. All patients underwent bilateral cataract surgery with implantation of a rotationally asymmetric multifocal IOL (Lentis Mplus LS-312 MF30, Oculentis GmbH). Distance and near visual acuity outcomes, intraocular aberrations, defocus curve, and quality of life (assessed using the National Eye Institute Visual Functioning Questionnaire-25) were evaluated postoperatively (mean follow-up: 6.42±2.24 months). A significant improvement in distance visual acuity was found postoperatively (P<.01). Mean postoperative logMAR distance-corrected near visual acuity was 0.19±0.12 (∼20/30). Corrected distance visual acuity and near visual acuity of 20/20 or better were achieved by 30.8% and 7.7% of eyes, respectively. Of all eyes, 96.2% had a postoperative addition between 0 and 1.00 diopter (D). The defocus curve showed two peaks of maximum visual acuity (0 and 3.00 D of defocus), with an acceptable range of intermediate vision. LogMAR visual acuity corresponding to near defocus was directly correlated with some higher order intraocular aberrations (r⩾0.44, P⩽.04). Some difficulties evaluated with the quality of life test correlated directly with near and intermediate visual acuity (r⩾0.50, P⩽.01). The Lentis Mplus multifocal IOL provides good distance, intermediate, and near visual outcomes; however, the induced intraocular aberrometric profile may limit the potential visual benefit. Copyright 2012, SLACK Incorporated.
Beebe, David C; Shui, Ying-Bo; Siegfried, Carla J; Holekamp, Nancy M; Bai, Fang
2014-05-01
Oxygen levels in the eye are generally low and tightly regulated. Oxygen enters the eye largely by diffusion from retinal arterioles and through the cornea. In intact eyes, oxygen from the retinal arterioles diffuses into the vitreous body. There is a decreasing oxygen gradient from the retina to the lens, established by oxygen consumption by ascorbate in the vitreous fluid and lens metabolism. Age-related degeneration of the vitreous body or removal during vitrectomy exposes the posterior of the lens to increased oxygen, causing nuclear sclerotic cataracts. Lowering oxygen in the vitreous, as occurs in patients with ischemic diabetic retinopathy, protects against cataracts after vitrectomy. Vitrectomy and cataract surgery increase oxygen levels at the trabecular meshwork and with it the risk of open angle glaucoma. Two additional risk factors for glaucoma, African heritage and having a thinner cornea, are also associated with increased oxygen in the anterior chamber angle. Preservation of the vitreous body and the lens, two important oxygen consumers, would protect against nuclear sclerotic cataracts and open angle glaucoma. Delaying removal of the lens for as long as possible after vitrectomy would be an important step in delaying ocular hypertension and glaucoma progression.
Crystalens HD intraocular lens analysis using an adaptive optics visual simulator.
Pérez-Vives, Cari; Montés-Micó, Robert; López-Gil, Norberto; Ferrer-Blasco, Teresa; García-Lázaro, Santiago
2013-12-01
To compare visual and optical quality of the Crystalens HD intraocular lens (IOL) with that of a monofocal IOL. The wavefront aberration patterns of the monocular Akreos Adapt AO IOL and the single-optic accommodating Crystalens HD IOL were measured in a model eye. The Crystalens IOL was measured in its nonaccommodative state and then, after flexing the haptic to produce 1.4 mm of movement, in its accommodative state. Using an adaptive optics system, subjects' aberrations were removed and replaced with those of pseudophakes viewing with either lens. Monocular distance visual acuity (DVA) at high (100%), medium (50%), and low (10%) contrast and contrast sensitivity (CS) were measured for both IOL optics. Near VA (NVA) and CS were measured for the Crystalens HD IOL in its accommodative state. Depth of focus around the distance and near focus was also evaluated for the Crystalens HD IOL. Modulation transfer function (MTF), point spread function (PSF), and Strehl ratio were also calculated. All measures were taken for 3- and 5-mm pupils. The MTF, PSF, and Strehl ratio showed comparable values between IOLs (p > 0.05). There were no significant differences in DVA and CS between IOLs for all contrasts and pupils (p > 0.05). When spherically focused, mean DVA and NVA with the Crystalens HD IOL were ≥20/20 at 100 and 50% contrasts for both pupils. Monocular DVA, NVA, and CS were slightly better with 3- than 5-mm pupils, but without statistically significant differences. The Crystalens HD IOL showed about 0.75 and 0.50 D of depth of focus in its accommodative state and nonaccommodative state, respectively. The optical and visual quality with the nonaccommodatied Crystalens HD IOL was comparable to that of a monofocal IOL. If this lens can move 1.4 mm in the eye, it will provide high-quality optics for near vision as well.
Rapidly progressive idiopathic lenticular astigmatism.
Tint, Naing L; Jayaswal, Rakesh; Masood, Imran; Maharajan, V Senthil
2007-02-01
A myopic 43-year-old woman with early nuclear sclerotic cataract developed more than 11.0 diopters (D) of astigmatism over a 6-month period. This was found to be lenticular in origin. Phacoemulsification with intraocular lens implantation was performed, resulting in residual astigmatism of 0.75 D. To our knowledge, this is the first case of rapidly progressive lenticular astigmatism in an otherwise healthy eye with early nuclear sclerotic cataract.
[Sir Harold Ridley--the creator of modern cataract surgery].
Obuchowska, Iwona; Mariak, Zofia
2005-01-01
In February 2000, the worldwide ophthalmology community celebrated the 50th anniversary of one of the twentieth century's most important innovations in eye care--the implantation of the first intraocular lens after cataract extraction by Sir Harold Ridley. It was the initiation of a golden age for the development of ophthalmology, especially cataract surgery. In our paper we would like to remember this outstanding English ophthalmologist and his great invention.
Ryu, Ik Hee; Han, Jinu; Lee, Hyung Keun; Kim, Jin Kook
2014-01-01
Purpose To evaluate the change of accommodation-convergence parameters after implantation of Artisan phakic intraocular lens (PIOL). Methods Prospective study for the patients with the Artisan PIOL implantation was performed. A total of 37 patients (3 males and 34 females) enrolled the study. Preoperatively, convergence amplitude, the stimulus accommodative convergence per unit of accommodation (AC/A) ratio and the near point of convergence (NPC) were evaluated. After the Artisan PIOL implantation, the identical evaluations were repeated at 1 week, 1, 3, and 6 months after the surgery. Results Mean age was 24.3 ± 4.8 years old, and preoperative refractive error was -8.92 ± 4.13 diopters (D). After the implantation, mean refractive errors significantly decreased to within ±1.00 D, and noticeable complications were not found. The convergence amplitude and the stimulus AC/A ratio increased 1 month after the surgery, but progressively stabilized afterward to near preoperative values. NPC didn't show any significant change over follow-up period up to 6 months. Conclusions These results regarding implantation of the Artisan PIOL revealed the increase of accommodation-convergence relationship within first 1 month after the surgery, but progressive stabilization was noted during follow-up periods. PMID:24688257
Yang, Shuo; Wang, Bin; Zhang, Yangyang; Zhai, Hualei; Wang, Junyi; Wang, Shuang; Xie, Lixin
2017-09-01
To evaluate an interlaced triple procedure that involved penetrating keratoplasty (PKP), extracapsular cataract extraction (ECCE) using diathermy capsulotomy, and nonopen-sky intraocular lens (IOL) implantation.This retrospective study involved data from 34 patients who were diagnosed with severe corneal opacities and cataracts. These patients were divided into an interlaced procedure group (21 patients) and a traditional procedure group (13 patients). In the interlaced group, the method of continuous curvilinear capsulorhexis (CCC) was completed via diathermy capsulotomy. The donor corneal button was sutured at 8 positions (at equal intervals) using 10-0 nylon sutures, and the IOL was inserted into the capsular bag using a closed anterior chamber approach at the 10:30 to 12 o'clock positions between the sutures. In the traditional group, CCC was completed using side-port capsular forceps, and the IOL was implanted using an open anterior chamber approach.In the interlaced group, the CCC, open-sky, and total operation times were significantly shorter than in the traditional group (P < .05). Neither the best-corrected visual acuity (BCVA) nor corneal endothelial cell density was significantly different between the groups at 1 and 6 months after the operation.This interlaced triple procedure for the treatment of corneal diseases with cataracts appears to be feasible and practical.
Ouchi, M; Kinoshita, S
2015-01-01
Purpose To evaluate the postoperative outcomes of cataract eyes complicated with coexisting ocular pathologies that underwent implantation of a refractive multifocal intraocular lens (MIOL) with a surface-embedded near section. Methods LENTIS MPlus (Oculentis GmbH) refractive MIOLs were implanted in 15 eyes with ocular pathologies other than cataract (ie, six high-myopia eyes with an axial length longer than 28 mm, two fundus albipunctatus eyes, two branch retinal-vein occlusion eyes, four glaucoma eyes (one with high myopia), and two keratoconus eyes). Uncorrected or corrected distance and near visual acuity (VA) (UDVA, UNVA, CDVA, and CNVA), contrast sensitivity, and defocus curve were measured at 1 day and 6 months postoperatively, and each patient completed a 6-month postoperative questionnaire regarding vision quality and eyeglass use. Results Thirteen eyes (87%) registered 0 or better in CDVA and 12 eyes (73%) registered better than 0 in CNVA. Contrast sensitivity in the eyes of all patients was comparable to that of normal healthy subjects. No patient required eyeglasses for distance vision, but three patients (20%) required them for near vision. No patient reported poor or very poor vision quality. Conclusion With careful case selection, sectorial refractive MIOL implantation is effective for treating cataract eyes complicated with ocular pathologies. PMID:25744442
Multifocal Intraocular Lens Results in Correcting Presbyopia in Eyes After Radial Keratotomy.
Kim, Kyeong Hwan; Seok, Kyung-Won; Kim, Wan Soo
2017-11-01
To report results of multifocal intraocular lens (IOL) implantation in 2 patients with refractive error and presbyopia after previous radial keratotomy (RK). A refractive multifocal IOL with rotational asymmetry (LS313-MF30; Oculentis, Berlin, Germany) was implanted. The first patient was a 60-year-old man with myopia who underwent unilateral RK 20 years before. His uncorrected distance visual acuity (UDVA) was 20/400, and his distance corrected near vision was J9 in both eyes. Six months after bilateral surgery, his binocular UDVA and uncorrected near visual acuity (UNVA) improved to 20/20 and J1, respectively, although he experienced diurnal fluctuation. The second patient was a 55-year-old woman with hyperopia who underwent bilateral RK 18 years before. Uncorrected distance visual acuity was 20/25 in both eyes, but UNVA was between J9 and J10. Three months after unilateral surgery, UDVA and UNVA of the postsurgical eye improved to 20/20 and J1, respectively. Neither patient reported any significant photic phenomena, and both were satisfied with the results of treatment. The desirable clinical outcomes and levels of satisfaction expressed by these patients indicate that surgery using this particular multifocal IOL may benefit presbyopic patients with previous RK.
Ouchi, M; Kinoshita, S
2015-05-01
To evaluate the postoperative outcomes of cataract eyes complicated with coexisting ocular pathologies that underwent implantation of a refractive multifocal intraocular lens (MIOL) with a surface-embedded near section. LENTIS MPlus (Oculentis GmbH) refractive MIOLs were implanted in 15 eyes with ocular pathologies other than cataract (ie, six high-myopia eyes with an axial length longer than 28 mm, two fundus albipunctatus eyes, two branch retinal-vein occlusion eyes, four glaucoma eyes (one with high myopia), and two keratoconus eyes). Uncorrected or corrected distance and near visual acuity (VA) (UDVA, UNVA, CDVA, and CNVA), contrast sensitivity, and defocus curve were measured at 1 day and 6 months postoperatively, and each patient completed a 6-month postoperative questionnaire regarding vision quality and eyeglass use. Thirteen eyes (87%) registered 0 or better in CDVA and 12 eyes (73%) registered better than 0 in CNVA. Contrast sensitivity in the eyes of all patients was comparable to that of normal healthy subjects. No patient required eyeglasses for distance vision, but three patients (20%) required them for near vision. No patient reported poor or very poor vision quality. With careful case selection, sectorial refractive MIOL implantation is effective for treating cataract eyes complicated with ocular pathologies.
Experimental characterization of the imaging properties of multifocal intraocular lenses
NASA Astrophysics Data System (ADS)
Gobbi, Pier Giorgio; Fasce, Francesco; Bozza, Stefano; Brancato, Rosario
2003-07-01
Many different types of intraocular lenses (IOL) are currently available for implantation, both as crystalline lens replacements and as phakic refractive elements. Their optical design is increasingly sophisticated, including aspherical surface profiles and multi-zone multifocal structures, however a quantitative and comparative characterization of their imaging properties is lacking. Also a qualitative visualization of their properties would be very useful for patients in the lens choice process. To this end an experimental eye model has been developed to allow for simulated in-vivo testing of IOLs. The model cornea is made of PMMA with a dioptric power of 43 D, and it has an aspherical profile designed to minimize spherical aberration across the visible spectrum. The eye model has a variable iris and a mechanical support to accomodate IOLs, immersed in physiological solution. The eye length is variable and the retina is replaced by a glass plate. The image formed on this "retina" is optically conjugated to a CCD camera, with a suitable magnification in order to mimic the human fovea resolution, and displayed onto a monitor. With such an opto-mechanical eye model, two types of images have been used to characterize IOLs: letter charts and variable contrast gratings, in order to directly simulate human visual acuity and contrast sensitivity.
Topical anesthesia in phacoemulsification.
Waheeb, Saad
2010-09-01
To evaluate the efficacy of topical anesthesia; topical Benoxinate 0.4% (Oxybuprocaine) and Xylocaine (Lidocaine) gel, in selected cataract patients as an alternative to peribulbar or retrobulbar block anesthesia during cataract surgery. Prospective non-comparative evaluation of patients' and surgeon's satisfaction at the end of the procedure. Three hundred patients (300 eyes) were included in the study. The procedure was explained to patients with details regarding what will happen and what to expect during surgery. All patients received topical anesthesia with Benoxinate 0.4% eye drops and Xylocaine gel 2%. All surgeries were done by the same surgeon using the same machine (updated LEGACY phacoemulsifier, Alcon) and approach (clear corneal incision) and followed by a foldable intraocular lens (IOL) implantation. None of the patients had severe pain during the procedure; only 2% (six of 300) required use of intravenous sedation (Propofol), both the surgeon's and the patients' satisfaction were high. Eye movements and blepharospasm were not significant problems, and no serious complications occurred. Rate of vitreous loss due to posterior capsule tear/rupture was within literature reported range and not different from our previous experience. Topical anesthesia is a satisfactory and safe alternative to retrobulbar and peribulbar anesthesia for clear corneal phacoemulsification and intraocular lens implantation in selected cataract patients in the hands of experienced cataract surgeon.
Topical anesthesia in phacoemulsification
Waheeb, Saad
2010-01-01
Purpose: To evaluate the efficacy of topical anesthesia; topical Benoxinate 0.4% (Oxybuprocaine) and Xylocaine (Lidocaine) gel, in selected cataract patients as an alternative to peribulbar or retrobulbar block anesthesia during cataract surgery. Materials and Methods: Prospective non-comparative evaluation of patients’ and surgeon’s satisfaction at the end of the procedure. Three hundred patients (300 eyes) were included in the study. The procedure was explained to patients with details regarding what will happen and what to expect during surgery. All patients received topical anesthesia with Benoxinate 0.4% eye drops and Xylocaine gel 2%. All surgeries were done by the same surgeon using the same machine (updated LEGACY phacoemulsifier, Alcon) and approach (clear corneal incision) and followed by a foldable intraocular lens (IOL) implantation. Results: None of the patients had severe pain during the procedure; only 2% (six of 300) required use of intravenous sedation (Propofol), both the surgeon’s and the patients’ satisfaction were high. Eye movements and blepharospasm were not significant problems, and no serious complications occurred. Rate of vitreous loss due to posterior capsule tear/rupture was within literature reported range and not different from our previous experience. Conclusion: Topical anesthesia is a satisfactory and safe alternative to retrobulbar and peribulbar anesthesia for clear corneal phacoemulsification and intraocular lens implantation in selected cataract patients in the hands of experienced cataract surgeon. PMID:21120050
Bai, Ling; Zhang, Jin; Chen, Ling; Ma, Ting; Liang, Hou-Cheng
2015-01-01
AIM To compare posterior capsule opacification (PCO) degree and visual functions after phacoemulsification in eyes implanted with 360-degree square edge hydrophilic acrylic intraocular lens (IOL) (570C C-flex, Rayner) and sharp edge hydrophobic acrylic IOL (Sensar AR40e, AMO) in diabetic patients. METHODS Sixty diabetic patients underwent uneventful phacoemulsification and randomly implanted one of the two IOLs. The PCO value was measured by retroillumination photographs and Evaluation of Posterior Capsule Opacification (EPCO) 2000 image-analysis software at 1, 6, 12, and 24mo after surgery. Visual acuity, and contrast sensitivity in photopic and mesopic conditions were also examined at each follow up time point. The incidence of eye that required Nd:YAG laser posterior capsulotomy were also compared. RESULTS There was not any statistically significant difference in PCO scores between Rayner C-flex 570C group and Sensar AR40e group at each follow up time point. Visual acuity, Nd:YAG capsulotomy incidence and contrast sensitivity also had no significant difference during the 24mo follow-up. CONCLUSION For diabetic patients, Rayner 570C C-flex and Sensar AR40e IOLs are same effective for prevent PCO. The 360-degree square edge design maybe is a good alternative technique to improve PCO prevention. PMID:26309870
Bai, Ling; Zhang, Jin; Chen, Ling; Ma, Ting; Liang, Hou-Cheng
2015-01-01
To compare posterior capsule opacification (PCO) degree and visual functions after phacoemulsification in eyes implanted with 360-degree square edge hydrophilic acrylic intraocular lens (IOL) (570C C-flex, Rayner) and sharp edge hydrophobic acrylic IOL (Sensar AR40e, AMO) in diabetic patients. Sixty diabetic patients underwent uneventful phacoemulsification and randomly implanted one of the two IOLs. The PCO value was measured by retroillumination photographs and Evaluation of Posterior Capsule Opacification (EPCO) 2000 image-analysis software at 1, 6, 12, and 24mo after surgery. Visual acuity, and contrast sensitivity in photopic and mesopic conditions were also examined at each follow up time point. The incidence of eye that required Nd:YAG laser posterior capsulotomy were also compared. There was not any statistically significant difference in PCO scores between Rayner C-flex 570C group and Sensar AR40e group at each follow up time point. Visual acuity, Nd:YAG capsulotomy incidence and contrast sensitivity also had no significant difference during the 24mo follow-up. For diabetic patients, Rayner 570C C-flex and Sensar AR40e IOLs are same effective for prevent PCO. The 360-degree square edge design maybe is a good alternative technique to improve PCO prevention.
Silicone intraocular lens surface calcification in a patient with asteroid hyalosis.
Matsumura, Kazuhiro; Takano, Masahiko; Shimizu, Kimiya; Nemoto, Noriko
2012-07-01
To confirm a substance presence on the posterior intraocular lens (IOL) surface in a patient with asteroid hyalosis. An 80-year-old man had IOLs for approximately 12 years. Opacities and neodymium-doped yttrium aluminum garnet pits were observed on the posterior surface of the right IOL. Asteroid hyalosis and an epiretinal membrane were observed OD. An IOL exchange was performed on 24 March 2008, and the explanted IOL was analyzed using a light microscope and a transmission electron microscope with a scanning electron micrograph and an energy-dispersive X-ray spectrometer for elemental analysis. To confirm asteroid hyalosis, asteroid bodies were examined with the ionic liquid (EtMeIm+ BF4-) method using a field emission scanning electron microscope (FE-SEM) with digital beam control RGB mapping. X-ray spectrometry of the deposits revealed high calcium and phosphorus peaks. Spectrometry revealed that the posterior IOL surface opacity was due to a calcium-phosphorus compound. Examination of the asteroid bodies using FE-SEM with digital beam control RGB mapping confirmed calcium and phosphorus as the main components. Calcium hydrogen phosphate dihydrate deposits were probably responsible for the posterior IOL surface opacity. Furthermore, analysis of the asteroid bodies demonstrated that calcium and phosphorus were its main components.
Mouney, Meredith C; Townsend, Wendy M; Moore, George E
2012-12-01
To determine whether differences exist in the calculated intraocular lens (IOL) strengths of a population of adult horses and to assess the association between calculated IOL strength and horse height, body weight, and age, and between calculated IOL strength and corneal diameter. 28 clinically normal adult horses (56 eyes). Axial globe lengths and anterior chamber depths were measured ultrasonographically. Corneal curvatures were determined with a modified photokeratometer and brightness-mode ultrasonographic images. Data were used in the Binkhorst equation to calculate the predicted IOL strength for each eye. The calculated IOL strengths were compared with a repeated-measures ANOVA. Corneal curvature values (photokeratometer vs brightness-mode ultrasonographic images) were compared with a paired t test. Coefficients of determination were used to measure associations. Calculated IOL strengths (range, 15.4 to 30.1 diopters) differed significantly among horses. There was a significant difference in the corneal curvatures as determined via the 2 methods. Weak associations were found between calculated IOL strength and horse height and between calculated IOL strength and vertical corneal diameter. Calculated IOL strength differed significantly among horses. Because only weak associations were detected between calculated IOL strength and horse height and vertical corneal diameter, these factors would not serve as reliable indicators for selection of the IOL strength for a specific horse.
Firl, Kevin C; Montezuma, Sandra R
2016-11-09
Post-operative endophthalmitis is a serious complication of intraocular surgery which may present acutely or chronically. Chronic post-operative endophthalmitis is characterized by decreased visual acuity, mild pain, and low-grade uveitis several weeks or months after intraocular surgery which may be responsive to corticosteroids, but recur upon tapering. Low virulence organisms such as Propionibacterium acnes are the most common culprit organisms, and treatment most often consists of both intravitreal antibiotic injections and surgery. Aniridia is a condition defined by total or partial loss of the iris and leads to decreased visual quality marked by glare and photophobia. Treatment of complex or severe cases of traumatic aniridia in which surgical repair is difficult may consist of implantation of iris prostheses, devices designed to reduce symptoms of aniridia. Though chronic, post-operative endophthalmitis has been associated with most intraocular surgeries including intraocular lens implantation after cataract removal, it has never been described in a patient with an iris prosthesis. In this case report, we describe the case of a 49 year old, male construction worker with traumatic aniridia who experienced chronic, recurrent low-grade intraocular inflammation and irritation for months after implantation of the Ophtec 311 prosthetic iris. Symptoms and signs of inflammation improved temporarily with sub-Tenon's capsule triamcinolone injections. Ultimately after more than 2 post-operative years, the iris prosthesis was explanted, and intravitreal cultures showed P. acnes growth after 5 days. Intravitreal antibiotics treated the infection successfully. To our knowledge, this is the first reported case of chronic, post-operative endophthalmitis in a patient with an iris prosthesis. Chronic, post-operative endophthalmitis may be a difficult to identify in the context of traumatic aniridia and iris prosthesis implantation due to other potential etiologies of chronic intraocular inflammation such as implant-induced chafing. Clinicians should suspect chronic, post-operative endophthalmitis in any case of recurrent, low-grade intraocular inflammation.
Shafiee, Afshin; McIntire, Greg L; Sidebotham, Lisa C; Ward, Keith W
2008-01-01
To determine the vitreous volume, and retinal and lens wet weights in male and female Göttingen minipigs of different age groups. Vitreous, lens and retina were isolated from fresh minipig eyes. Vitreous volume, lens and retina weight were measured and allometric scaling was utilized to predict these parameters. There were no gender differences in body weights or retina and lens weights in the three age groups examined in this study. For vitreous volumes, females had a significantly larger volume (approximately 10%-12%) than males in the 4-6 and 6-8 month, but not in the 8-11-month group. The mean body weight increased from 12.2 +/- 2.6 kg (4-6 months) to 19.4 +/- 4.0 kg (8-11 months). In the same period, the mean vitreous volume increased from 2.00 +/- 0.28 to 2.67 +/- 0.31 mL, while the mean retinal and lens weights increased from 114 +/- 22 to 126 +/- 17 mg, and from 298 +/- 26 to 392 +/- 15 mg, respectively. Allometric analysis between six species for vitreous volume and four species for lens weight covering a weight range of 260-fold was not able to estimate the vitreous volume, but it did predict the lens weight in 8-11 months minipigs. Overall these measurements add important context to intraocular pharmacology studies, and will help in the improved design and interpretation of such experiments.
Zeng, Yanfeng; Fan, Licheng; Lu, Peirong
2017-04-01
Objective To observe the treatment effects of chop hook-assisted phacoemulsification surgery in patients with crystalline lens dislocation. Methods Thirty-seven eyes with cataracts and crystalline lens dislocations underwent cataract surgery. An L-shaped chop hook was introduced into the anterior chamber, and the tip was pushed or pulled to the centre of the anterior capsular edge of the zonular dialysis during the cataract operation. Postoperative follow-up was conducted for ≥ 1 month. Results All patients' postoperative visual abilities improved except one patient with glaucoma. One patient who underwent -5D intraocular lens implantation exhibited vision of 1/50. Visual acuity was less than 6/20 in 6 eyes, 6/20 to 10/20 in 7 eyes, and greater than 10/20 in 22 eyes. Conclusions L-shaped chop hooks can be used to push or pull the anterior capsular edge of the zonular dialysis for protection and avoidance of further zonular damage. This strategy provides satisfactory effects and reduces use of additional instruments.
Kara-Junior, Newton; Espindola, Rodrigo F; Gomes, Beatriz A F; Ventura, Bruna; Smadja, David; Santhiago, Marcony R
2011-12-01
To evaluate the possible side effects and potential protection 5 years after implantation of an intraocular lens (IOL) with a blue-light filter (yellow tinted). Ophthalmology Department, University of São Paulo, São Paulo, Brazil. Prospective randomized clinical study. Patients with bilateral visually significant cataract randomly received an ultraviolet (UV) and blue light-filtering IOL (Acrysof Natural SN60AT) in 1 eye and an acrylic UV light-filtering only IOL (Acrysof SA60AT) in the fellow eye. The primary outcome measures were contrast sensitivity, color vision, and macular findings 5 years after surgery. The study enrolled 60 eyes of 30 patients. There were no significant clinical or optical coherence tomography findings in terms of age-related macular degeneration in any eye. There were no statistically significant differences in central macular thickness between the 2 IOL groups (P=.712). There were also no significant between-group differences under photopic or scotopic conditions at any spatial frequency studied. No statistically significant differences in the color discrimination test were found between the 2 IOL groups (P=.674). After 5 years, there were no significant differences in color perception, scotopic contrast sensitivity, or photopic contrast sensitivity between the blue light-filtering (yellow-tinted) IOL and the IOL with a UV-light filter only (untinted). The potential advantage of the tinted IOL in providing protection to macular cells remains unclear. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Extralenticular and Lenticular Aspects of Accommodation and Presbyopia in Human Versus Monkey Eyes
Croft, Mary Ann; McDonald, Jared P.; Katz, Alexander; Lin, Ting-Li; Lütjen-Drecoll, Elke; Kaufman, Paul L.
2013-01-01
Purpose. To determine if the accommodative forward movements of the vitreous zonule and lens equator occur in the human eye, as they do in the rhesus monkey eye; to investigate the connection between the vitreous zonule posterior insertion zone and the posterior lens equator; and to determine which components—muscle apex width, lens thickness, lens equator position, vitreous zonule, circumlental space, and/or other intraocular dimensions, including those stated in the objectives above—are most important in predicting accommodative amplitude and presbyopia. Methods. Accommodation was induced pharmacologically in 12 visually normal human subjects (ages 19–65 years) and by midbrain electrical stimulation in 11 rhesus monkeys (ages 6–27 years). Ultrasound biomicroscopy imaged the entire ciliary body, anterior and posterior lens surfaces, and the zonule. Relevant distances were measured in the resting and accommodated eyes. Stepwise regression analysis determined which variables were the most important predictors. Results. The human vitreous zonule and lens equator move forward (anteriorly) during accommodation, and their movements decline with age, as in the monkey. Over all ages studied, age could explain accommodative amplitude, but not as well as accommodative lens thickening and resting muscle apex thickness did together. Accommodative change in distances between the vitreous zonule insertion zone and the posterior lens equator or muscle apex were important for predicting accommodative lens thickening. Conclusions. Our findings quantify the movements of the zonule and ciliary muscle during accommodation, and identify their age-related changes that could impact the optical change that occurs during accommodation and IOL function. PMID:23745002
Simplified mathematics for customized refractive surgery.
Preussner, Paul Rolf; Wahl, Jochen
2003-03-01
To describe a simple mathematical approach to customized corneal refractive surgery or customized intraocular lens (IOL) design that allows "hypervision" and to investigate the accuracy limits. University eye hospital, Mainz, Germany. Corneal shape and at least 1 IOL surface are approximated by the well-known Cartesian conic section curves (ellipsoid, paraboloid, or hyperboloid). They are characterized by only 2 parameters, the vertex radius and the numerical eccentricity. Residual refraction errors for this approximation are calculated by numerical ray tracing. These errors can be displayed as a 2-dimensional refraction map across the pupil or by blurring the image of a Landolt ring superimposed on the retinal receptor grid, giving an overall impression of the visual outcome. If the eye is made emmetropic for paraxial rays and if the numerical eccentricities of the cornea and lens are appropriately fitted to each other, the residual refractive errors are small enough to allow hypervision. Visual acuity of at least 2.0 (20/10) appears to be possible, particularly for mesopic pupil diameters. However, customized optics may have limited application due to their sensitivity to misalignment errors such as decentrations or rotations. The mathematical approach described by Descartes 350 years ago is adequate to calculate hypervision optics for the human eye. The availability of suitable mathematical tools should, however, not be viewed with too much optimism as long as the accuracy of the implementation in surgical procedures is limited.
Application of the polychromatic defocus transfer function to multifocal lenses.
Schwiegerling, Jim; Choi, Junoh
2008-11-01
To model the performance of multifocal lenses in polychromatic lighting. The defocus transfer function (DTF) is a mathematical technique for illustrating the optical transfer function for all levels of defocus at a given wavelength. A polychromatic version of the DTF is developed that accounts for changes in cutoff frequency, reduction in diffraction efficiency, ocular chromatic aberration, and photoreceptor spectral sensitivity. The differences between the monochromatic and polychromatic DTF are illustrated with a diffractive multifocal intraocular lens. Polychromatic analysis shows an increase in depth of field of diffractive lenses relative to assessment at a single wavelength. The polychromatic DTF is a useful tool for analyzing presbyopia treatments under "white-light" viewing conditions and provides feedback to lens designers on anticipated performance.
Alió, Jorge L; Plaza-Puche, Ana B; Javaloy, Jaime; Ayala, María José
2012-02-01
To compare the visual outcomes and intraocular optical quality observed postoperatively in patients implanted with a rotationally asymmetric multifocal intraocular lens (IOL) and an apodized diffractive multifocal IOL. Seventy-four consecutive eyes of 40 cataract patients (age range: 36 to 79 years) were divided into two groups: zonal refractive group, 39 eyes implanted with a rotationally asymmetric multifocal IOL (Lentis Mplus LS-312 IOL, Oculentis GmbH); and diffractive group, 35 eyes implanted with an apodized diffractive multifocal IOL (ReSTOR SN6AD3, Alcon Laboratories Inc). Distance and near visual acuity outcomes, contrast sensitivity, intraocular optical quality, and defocus curves were evaluated during 3-month follow-up. Calculation of the intraocular aberrations was performed by subtracting corneal aberrations from total ocular aberrations. Uncorrected near visual acuity and distance-corrected near visual acuity were better in the diffractive group than in the zonal refractive group (P=.01), whereas intermediate visual acuity (defocus +1.00 and +1.50 diopters) was better in the zonal refractive group. Photopic contrast sensitivity was significantly better in the zonal refractive group (P=.04). Wavefront aberrations (total, higher order, tilt, primary coma) were significantly higher in the zonal refractive group than in the diffractive group (P=.02). Both multifocal IOLs are able to successfully restore visual function after cataract surgery. The zonal refractive multifocal IOL provides better results in contrast sensitivity and intermediate vision, whereas the diffractive multifocal IOL provides better near vision at a closer distance. Copyright 2012, SLACK Incorporated.
Németh, J; Molnár, F; Kocur, I
2002-01-01
To describe eye health-care services provided by in patient Departments of Ophthalmology in Hungary as of 1998. A standardised questionnaire was sent to all Hungarian in-patient ophthalmic departments. The response rate was 100%, and data from six university departments and 56 hospitals with ophthalmic units are summarised. During the 12-month period, a total of 78,008 ophthalmic operations were performed, by 489 ophthalmologists. They worked in 62 in-patient ophthalmic units having a total of 1952 beds. The cataract rate was 3564 operations per million inhabitants; intraocular lens implantation was performed on 97% of the cases. There were 591 corneal transplants, 1698 operations for retinal detachment and 510 vitrectomies for diabetic eye complications. The level of ophthalmic care in Hungary, judged on the basis of key objective parameters including number of ophthalmic specialists, number of ophthalmic beds, and the rates of surgery, generally conforms to standards prevailing in Western Europe, in spite of financial difficulties and the consequent lack of investment in new equipment and instruments, both major and minor.
Kammann, J; Kreiner, C F; Kaden, P
1994-08-01
Experience with intraocular lenses (IOL) made of PMMA dates back ca. 40 years, while silicone IOLs have been in use for only about 10 years. The biocompatibility of PMMA and silicone caoutchouc was tested in a comparative study investigating the growth of mouse fibroblasts on different IOL materials. Spectrophotometric determination of protein synthesis and liquid scintillation counting of DNA synthesis were carried out. The spreading of cells was planimetrically determined, and the DNA synthesis of individual cells in direct contact with the test sample was tested. The results showed that the biocompatibility of silicone lenses made of purified caoutchouc is comparable with that of PMMA lenses; there is no statistically significant difference. However, impurities arising during material synthesis result in a statistically significant inhibition of cell growth on the IOL surfaces.
Scleral fixation of one piece intraocular lens by injector implantation
Can, Ertuğrul; Başaran, Reşat; Gül, Adem; Birinci, Hakkı
2014-01-01
Aim of Study: With an ab-interno technique of transscleral suturing of current one-piece posterior chamber intraocular lenses (PC IOLs) by injector implantation in the absence of capsular support, we aimed to demonstrate the possibility of the implantation of one-piece acrylic PC IOLs that might be produced in the future for only scleral fixation through small clear corneal incision. Materials and Methods: Case report and literature review. Results: This procedure has been performed in eight aphakic eyes with four different types of IOLs. Good centration was achieved with minimal technical effort. All patients had well-centered and stable lenses postoperatively during 9-18 months follow-up. Conclusion: We managed to decrease the risks of surgical trauma and intricate surgical maneuvers requirement. With this technique, excessive fluid leakage and consecutive hypotony can be minimized. PMID:25230961
Elder, Mark J; Morlet, Nigel
2002-12-01
Australia and New Zealand continue to be at the forefront of endophthalmitis research. In this Clinical Controversy, an ophthalmologist from each country presents different approaches to the management of a 72-year-old patient with routine endophthalmitis following cataract surgery. Mark Elder concludes that this case needs aqueous and vitreous aspirates for culture and the initial treatment of choice is intracameral vancomycin and amikacin. The evidence for intravitreal steroids is equivocal. Systemic antibiotics are indicated if there is a possibility of a bacterial biofilm present on the intraocular lens. Nigel Morlet concludes that timely intervention with appropriate antibiotics delivered in the right concentration to the vitreous cavity is the crux of successful management of endophthalmitis. Aggressive treatment of the inflammatory response is also required to further reduce the damage to the intraocular structures. Both ophthalmologists agree that vitrectomy is not necessarily the most appropriate treatment option.
Pediatric ocular injury secondary to a Burmese python bite.
Behrens, Alice W; Jones, Maria H; Lowery, R Scott
2018-03-22
We report the case of a 6-year-old girl with a penetrating ocular injury caused by a Burmese python. She received intravenous cefazolin before presenting and was treated thereafter with daily topical antibiotics and atropine. Six weeks after injury, she underwent cataract extraction and sulcus implantation of an intraocular lens and iris synechiolysis, with postoperative patching. Final visual outcome was excellent despite no globe repair was performed. Published by Elsevier Inc.
Kahawita, Shyalle; Cugati, Sudha; Casson, Robert
2015-05-01
We present the case of a 69-year-old woman who presented with hypotony several years after an inadvertent cannula detachment presumably formed a cyclodialysis cleft during phacoemulsification cataract extraction and posterior chamber intraocular lens implantation in her right eye. To our knowledge, this is the first report of late hypotony maculopathy as a result of inadvertent cannula release. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.
Hayashi, Ken; Yoshida, Motoaki; Manabe, Shin-ichi; Hayashi, Hideyuki
2010-01-01
To compare all-distance visual acuity and contrast visual acuity with and without glare (glare visual acuity) between phakic eyes with a clear lens and pseudophakic eyes with a monofocal intraocular lens. Hayashi Eye Hospital, Fukuoka, Japan. This study comprised phakic), pseudophakic eyes in 4 age groups (40s, 50s, 60s, 70s). Corrected visual acuity from far to near, contrast visual acuity, and glare visual acuity were examined. The mean corrected intermediate and near visual acuities were significantly better in phakic eyes than in pseudophakic eyes in patients in their 40s and 50s (P
Savini, Giacomo; Næser, Kristian
2015-01-13
To investigate the influence of posterior corneal astigmatism, surgically-induced corneal astigmatism (SICA), intraocular lens (IOL) orientation, and effective lens position on the refractive outcome of toric IOLs. Five models were prospectively investigated. Keratometric astigmatism and an intended SICA of 0.2 diopters (D) were entered into model 1. Total corneal astigmatism, measured by a rotating Scheimpflug camera, was used instead of keratometric astigmatism in model 2. The mean postoperative SICA, the actual postoperative IOL orientation, and the influence of the effective lens position were added, respectively, into models 3, 4, and 5. Astigmatic data were vectorially described by meridional and torsional powers. A set of equations was developed to describe the error in refractive astigmatism (ERA) as the difference between the postoperative refractive astigmatism and the target refractive astigmatism. We enrolled 40 consecutive eyes. In model 1, ERA calculations revealed significant cylinder overcorrection in with-the-rule (WTR) eyes (meridional power = -0.59 ± 0.34 D, P < 0.0001) and undercorrection in against-the-rule (ATR) eyes (0.32 ± 0.42 D, P = 0.01). When total corneal astigmatism was used instead of keratometric astigmatism (model 2), the ERA meridional power decreased in WTR (-0.13 ± 0.42 D) and ATR (0.07 ± 0.59 D) eyes, both values being not statistically significant. Models 3 to 5 did not lead to significant improvement. Posterior corneal astigmatism exerts the highest influence on the ERA after toric IOL implantation. Basing calculations on total corneal astigmatism rather than keratometric astigmatism improves the prediction of the residual refractive astigmatism. Copyright 2015 The Association for Research in Vision and Ophthalmology, Inc.
Lindstrom, R L
1993-01-01
The clinical evaluation of the Food and Drug Administration study of the 3M diffractive multifocal intraocular lens (IOL) is presented here to demonstrate the results of 1-year postoperative data accumulated for 671 patients, the first of whom received the implant in 1987. Patients were selected for study if they had absence of preoperative pathology, were at least 60 years of age, and had a reasonable postoperative prognosis. Extensive evaluations took place at 4 to 6 months and 12 to 14 months after surgery, including five different visual acuity measurements and contrast sensitivity. All testing was completed on both eyes. Data from the fellow eye served as a control when implanted with a monofocal IOL. Overall uncorrected distance visual acuity at 1 year after surgery shows 57% patients with 20/40 or better acuity. In this same group, 78% achieved J3 or better near vision, which improved to 82% in the best case group. Uncorrected visual acuity of 20/40 or better and J3 or better was achieved by 50% of best case multifocal IOL patients, compared with 26% of the monofocal best case comparison group. Measurements of contrast sensitivity consistently document a small loss, which is considered clinically insignificant. Statistical analysis of satisfaction ratings shows that predictors of satisfaction include uncorrected distance acuity, final near acuity, and fellow eye spherical equivalent. This multifocal lens appears to work very well for most patients, with more than half having functional uncorrected distance and near vision. The study showed several considerations that are important for optimizing clinical performance and patient satisfaction: patient selection, realistic expectations, accurate biometry, and adequate control of surgical procedures.
Kang, Hyunseung; Lee, Min Woo; Byeon, Suk Ho; Koh, Hyoung Jun; Lee, Sung Chul; Kim, Min
2017-09-01
Our purpose was to describe the clinical course, and individualized management approaches, of patients with migration of a dexamethasone implant into the anterior chamber. This was a retrospective review of four patients with seven episodes of anterior chamber migration of a dexamethasone implant. After 924 intravitreal dexamethasone injections, anterior migration of the implant occurred in four eyes of four patients (0.43%). All four eyes were pseudophakic: one eye had a posterior chamber intraocular lens in the capsular bag but in a post-laser posterior capsulotomy state, two eyes had a sulcus intraocular lens (IOL), and one eye had an iris-fixated retropupillary IOL. All eyes had a prior vitrectomy and no lens capsule. The time interval from injection to detection of the implant migration ranged from 2 to 6 weeks. Of the four eyes with corneal edema, only one eye required a corneal transplantation, although it was unclear whether the implant migration was the direct cause of the corneal decompensation because the patient had a history of bullous keratopathy resulting from an extended history of uveitis. All patients underwent surgical intervention: two patients with a repositioning procedure, and the other two patients with removal due to repeated episodes, although surgical removal was not always necessary to reverse the corneal complications. In our study, not all patients required surgical removal of the implants. Repositioning the implant back into the vitreous cavity may be considered as an option in cases involving the first episode with no significant corneal endothelial decompensation. Considering potential anterior segment complications and the loss of drug effectiveness together, an individualized approach is recommended to obtain the best treatment outcomes and to minimize the risk of corneal complications.
Liu, Yan; Wang, Yuexin; Lv, Huibin; Jiang, Xiaodan; Zhang, Mingzhou; Li, Xuemin
2017-01-01
To investigate the efficacy of α-adrenergic agonist brimonidine either alone or combined with pirenzepine for inhibiting progressing myopia in guinea pig lens-myopia-induced models. Thirty-six guinea pigs were randomly divided into six groups: Group A received 2% pirenzepine, Group B received 0.2% brimonidine, Group C received 0.1% brimonidine, Group D received 2% pirenzepine + 0.2% brimonidine, Group E received 2% pirenzepine + 0.1% brimonidine, and Group F received the medium. Myopia was induced in the right eyes of all guinea pigs using polymethyl methacrylate (PMMA) lenses for 3 weeks. Eye drops were administered accordingly. Intraocular pressure was measured every day. Refractive error and axial length measurements were performed once a week. The enucleated eyeballs were removed for hematoxylin and eosin (H&E) and Van Gieson (VG) staining at the end of the study. The lens-induced myopia model was established after 3 weeks. Treatment with 0.1% brimonidine alone and 0.2% brimonidine alone was capable of inhibiting progressing myopia, as shown by the better refractive error (p=0.024; p=0.006) and shorter axial length (p=0.005; p=0.0017). Treatment with 0.1% brimonidine and 0.2% brimonidine combined with 2% pirenzepine was also effective in suppressing progressing refractive error (p=0.016; p=0.0006) and axial length (p=0.017; p=0.0004). The thickness of the sclera was kept stable in all groups except group F; the sclera was much thinner in the lens-induced myopia eyes compared to the control eyes. Treatment with 0.1% brimonidine alone and 0.2% brimonidine alone, as well as combined with 2% pirenzepine, was effective in inhibiting progressing myopia. The result indicates that intraocular pressure elevation is possibly a promising mechanism and potential treatment for progressing myopia.
Ichikawa, Kazuo
2014-07-01
Blood pressure and sleep duration may be influenced by retinal light exposure. Cataracts may exert such an influence by decreasing the transparency of the crystalline lens. A large-scale clinical study was conducted to examine changes in blood pressure and sleep duration after intraocular lens (IOL) implantation during cataract surgery and to investigate how different types of IOL influence the degree of these effects. Using a questionnaire, we collected information, including blood pressure measurement and sleep duration, from 1367 patients (1367 eyes) before IOL implantation, 1 week after IOL implantation and 1 month after IOL implantation. Systolic and diastolic blood pressures were significantly decreased in the total patient group after implantation. The decrease in systolic blood pressure 1 month after implantation was significantly more in patients who received a yellow-tinted IOL than it was in those who received an ultraviolet (UV) light-filtering IOL. The post-implantation sleep duration, including naps, became shorter in patients who had slept too much and became longer in those who had slept too little before IOL implantation. Our observations suggest that a yellow-tinted IOL is better for patients with high blood pressure than a UV light-filtering IOL. Furthermore, the yellow-tinted IOL is as good as the UV light-filtering IOL for improving sleep duration. A pale yellow-tinted IOL is likely to be superior to a moderate yellow-tinted IOL in terms of allowing patients to discriminate different colors. Thus, the pale yellow-tinted IOL appears to be better for patients than the UV light-filtering IOL and the moderate yellow-tinted IOL.
Terveen, Daniel C; Fram, Nicole R; Ayres, Brandon; Berdahl, John P
2016-02-01
To determine the visual outcomes and complications of a new small-incision technique for 4-point fixation of a hydrophilic acrylic posterior chamber intraocular lens (IOL) in the absence of capsule support. Three North American tertiary referral centers and a private practice. Retrospective case series. Secondary IOL placement was performed from 2011 to 2014. Indications for surgery, clinical results, and complications were analyzed. Primary outcomes included postoperative corrected distance visual acuity (CDVA) and surgical complications. Charts of 35 patients (37 eyes) were reviewed. The mean age at surgery was 56 years, and the mean follow-up was 6 months (range 3 to 24 months). Clinical indications included a dislocated IOL (30%), ocular trauma (19%), crystalline lens subluxation (19%), uveitis-glaucoma-hyphema syndrome (5%), post-complicated cataract (8%), congenital cataract (8%), and decompensated cornea (3%). The mean CDVA improved from 20/80 preoperatively to 20/40 postoperatively (P < .01). Thirty-six eyes (97%) had an improved or unchanged CDVA, and 1 eye (3%) had a reduced CDVA because of worsening glaucoma. Postoperative complications included ocular hypertension (24%), iritis (5%), wound leakage (3%), transient corneal edema (3%), glaucoma requiring a tube shunt (3%), and IOL dislocation (3%). Small-incision 4-point scleral fixation of the Akreos AO60 hydrophilic acrylic IOL in the absence of capsule support appears to be a safe and effective technique for secondary IOL placement. Drs. Berdahl and Ayres are consultants to Bausch & Lomb, Inc. Drs. Ayres and Fram have received speaker fees from Bausch & Lomb. Dr. Terveen does not have a financial or proprietary interest in any material or methods mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Eissa, Sherif A
2017-03-01
To assess the outcomes of sulcus implantation of the Visian ® implantable collamer lens (ICL) to correct pseudophakic myopic anisometropic amblyopia with myopic shift and/or primary refractive overcorrection. Prospective case series enrolled 14 pseudophakic eyes of 14 patients, 5-9 years old, with history of cataract surgery and primary in the bag-intraocular lenses (IOL) implantation, followed by myopic shift and/or refractive overcorrection and anisometropic amblyopia of variable degrees. All cases had implantation of a piggyback ICL/toric ICL, to correct the myopia/myopic astigmatism. Preoperatively, we evaluated the uncorrected distance visual acuity (UCVA), corrected distance visual acuity (CDVA), manifest refraction spherical equivalent (MRSE), intraocular pressure (IOP) and endothelial cell density (ECD). We assessed the position and vaulting of the ICLs on slit lamp examination and confirmed by Scheimpflug tomography. Postoperative follow-up was at 1st week and 1, 3, 6, 9, 12, 18 and 24 months. Uncorrected distance visual acuity improved in all cases, and CDVA improved in 11 amblyopic eyes (2-4 lines). There was no evidence of interlenticular opacification (ILO) throughout the 2-year follow-up. Two cases were complicated with early postoperative acute elevation of IOP and were controlled with topical beta-blockers. Postoperative acute anterior uveitis occurred in six eyes and controlled by topical steroids. Implantable collamer lens (ICL) vault was measured using Pentacam, with mean value of 470 ± 238 μm. Sulcus implantation of the secondary piggyback ICL to correct unilateral pseudophakic myopic refractive error in children was safe, efficient, predictable and well tolerated in management of anisometropic amblyopia in all eyes. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Aging and Age-Related Diseases of the Ocular Lens and Vitreous Body
Petrash, J. Mark
2013-01-01
Reduced quality of life and financial burden due to visual impairment and blindness begin to increase dramatically when individuals reach the age of 40. The major causes of age-related vision loss can be traced to changes to the structure and function of the lens, one of the tissues responsible for focusing light on the retina. Age-related nuclear cataracts, which are caused by aggregation and condensation of proteins, diminish vision because they impede the transmission and focusing of light on the retina. In addition to the slow-developing age-related form, cataracts often develop rapidly as a complication of ocular surgery, such as following vitrectomy or as a consequence of vitreous gel degeneration. Posterior capsular opacification, which can develop following cataract removal, is caused by proliferation and inappropriate accumulation of lens epithelial cells on the surfaces of intraocular lenses and the posterior lens capsule. Presbyopia is a loss of accommodative amplitude and reduced ability to shift focus from far to near objects. Onset of presbyopia is associated with an increase in lens hardness and reduced ability of the lens to change shape in response to ciliary muscle contraction. Avenues of promising research that seek to delay or prevent these causes of low vision are discussed in light of our current understanding of disease pathogenesis and some challenges that must be met to achieve success. PMID:24335070
Determinants of lens vault and association with narrow angles in patients from Singapore.
Tan, Gavin S; He, Mingguang; Zhao, Wanting; Sakata, Lisandro M; Li, Jialiang; Nongpiur, Monisha E; Lavanya, Raghavan; Friedman, David S; Aung, Tin
2012-07-01
To describe the distribution and determinants of lens vault and to investigate the association of lens vault with narrow angles. Prospective cross-sectional study. Phakic subjects 50 years and older were evaluated at a primary healthcare clinic with gonioscopy, partial laser interferometry, and anterior segment optical coherence tomography (AS-OCT). Narrow angles were defined as posterior trabecular meshwork not visible for ≥2 quadrants on non-indentation gonioscopy. Lens vault was defined as the perpendicular distance between the anterior pole of the crystalline lens and the horizontal line joining the 2 scleral spurs on horizontal AS-OCT scans. Analysis of covariance, multivariate logistic regression, and area under the receiver operating characteristic curves (AUC) were performed. Of the 2047 subjects recruited, 582 were excluded because of poor image quality or inability to locate scleral spurs, leaving 1465 subjects for analysis. Eyes with narrow angles had greater lens vault compared to eyes with open angles (775.6 µm vs 386.5 µm, P < .0001). Women had significantly greater lens vault than men (497.28 µm vs 438.56 µm, P < .001), and lens vault increased significantly with age (P for trend <.001). Adjusted for age and sex, significant associations with greater lens vault were shorter axial length, shallower anterior chamber depth(ACD), higher intraocular pressure, and more hyperopic spherical equivalent (all P < .001). On multivariate analysis, subjects with lens vault >667.6 µm were more likely to have narrow angles (OR 2.201, 95% CI: 1.070-4.526) compared to those with lens vault ≤462.7 µm. The AUC for lens vault (0.816) and ACD (0.822) for detecting narrow angles were similar (P = .582). Lens vault was independently associated with narrow angles and may be useful in screening to detect eyes with narrow angles. Copyright © 2012 Elsevier Inc. All rights reserved.
Management of cataract in uveitis patients.
Conway, Mandi D; Stern, Ethan; Enfield, David B; Peyman, Gholam A
2018-01-01
This review is timely because the outcomes of surgical invention in uveitic eyes with cataract can be optimized with adherence to strict anti-inflammatory principles. All eyes should be free of any cell/ flare for a minimum of 3 months preoperatively. Another helpful maneuver is to place dexamethasone in the infusion fluid or triamcinolone intracamerally at the end of surgery. Recent reports about the choice of intraocular lens material or lens design are germane to the best surgical outcome. Integrating these findings will promote better visual outcomes and allow advancement in research to further refine these surgical interventions in high-risk uveitic eyes. Control of inflammation has been shown to greatly improve postoperative outcomes in patients with uveitis. Despite better outcomes, more scientific research needs to be done regarding lens placement and materials and further research needs to adhere to the standardized reporting of uveitis nomenclature. Future studies should improve postoperative outcomes in eyes with uveitis so that they approach those of eyes undergoing routine cataract procedures.
Shimizu, Kimiya; Kamiya, Kazutaka; Igarashi, Akihito; Kobashi, Hidenaga
2016-04-01
The study shows a promising next-generation surgical option for the correction of moderate to high ametropia. Hole implantable collamer lens (ICL), STAAR Surgical, is a posterior chamber phakic intraocular lens with a central artificial hole. As yet, however, no long-term comparison of the clinical results of the implantation of ICLs with and without such a hole has hitherto been conducted. A prospective, randomized, controlled trial was carried out in order to compare the long-term clinical outcomes of the implantation, in such eyes, of ICLs with and without a central artificial hole.Examinations were conducted of the 64 eyes of 32 consecutive patients with spherical equivalents of -7.53 ± 2.39 diopters (D) (mean ± standard deviation) in whom implantation of a Hole ICL was performed in 1 eye, and that of a conventional ICL was carried out in the other, by randomized assignment. Before 1, 3, and 6 months, and 1, 3, and 5 years after surgery, the safety, efficacy, predictability, stability, intraocular pressure, endothelial cell density, and adverse events of the 2 surgical techniques were assessed and compared over time.The measurements of LogMAR uncorrected and corrected distance visual acuity 5 years postoperatively were -0.17 ± 0.14 and -0.24 ± 0.08 in the Hole ICL group, and -0.16 ± 0.10 and -0.25 ± 0.08 in the conventional ICL group. In these 2 groups, 96% and 100% of eyes, respectively, were within 1.0 D of the targeted correction 5 years postoperatively. Manifest refraction changed by -0.17 ± 0.41 D and -0.10 ± 0.26 D occurred in from 1 month to 5 years in the Hole and conventional ICL groups, respectively. Only 1 eye (3.1%), which was in the conventional ICL group, developed an asymptomatic anterior subcapsular cataract.Both Hole and conventional ICLs corrected of ametropia successfully throughout the 5-year observation period. It appears likely that the presence of the central hole does not significantly affect these visual and refractive outcomes. UMIN000018771.
Extracapsular cataract extraction with and without intra-ocular lenses in black patients.
Welsh, N H
1992-04-04
Cataracts are the commonest cause of blindness in Third-World countries and cataract extraction is the commonest eye operation performed anywhere. Patients require optical correction after surgery either in the form of an intra-ocular lens (IOL) or bifocal aphakic glasses. The standard operative procedure in First-World countries is an extracapsular cataract extraction with an IOL. This type of operation has been thought to be contraindicated in black patients because of the complications and lack of adequate postoperative follow-up. During 1987-1989 3,144 cataract extractions, of which 2,157 were simple extracapsular extractions and 987 had IOLs inserted, were performed at the above hospitals. The two groups were compared for complications and visual results. The complications were similar in both groups and were acceptable, therefore posterior lens implantation confers no additional risk on routine extracapsular cataract extraction. The visual results in the IOL group with and without additional glasses were compared with those patients who had correcting aphakic glasses. In the corrected IOL group, 98% of patients saw better than 6/24, whereas in the aphakic spectacle group, 87.5% saw 6/24 or better. Since the majority of black patients cannot afford costly prescribed spectacles, it was important to analyse the visual acuity in patients who had IOLs and were uncorrected; 81.6% saw 6/24 or better. IOLs in black patients are therefore indicated but the disadvantage is the cost.
Uchio, Eiichi; Kadonosono, Kazuaki; Matsuoka, Yasuhiro; Goto, Satoru
2004-02-01
To determine the physical and mechanical conditions of an impacting air bag that would rupture an eye with a transsclerally fixated posterior chamber intraocular lens (IOL). Numerical simulation study on a computer. Simulations in a model human eye were performed with a computer using the finite element analysis program PAM-CRASH (Nihon ESI). The air bag was set to impact the surface of an eye with a transsclerally fixated posterior chamber IOL at various velocities. The tensile force limit of a 10-1 polypropylene suture was assumed to be 0.16 N, which is specified in the U.S. Pharmacopeia XXII. At the lowest velocity of 20.0 m/s, 10-0 polypropylene sutures were not likely to break. Sutures fixating the IOL might break and a corneoscleral incision was likely to open after 0.3 second at the medium impacting velocity (30 m/s). Suture rupture was very likely at the highest velocity (40 m/s) since the tensile force on the sutures continuously exceeded the breaking force after the impact. In an eye with a transsclerally fixated posterior chamber IOL, severe ocular trauma can be caused by an air bag at high velocity. Small individuals such as elderly women are at greater risk for air-bag ocular injury. Further research on modifying air-bag design and deployment is important to minimize the risk for ocular injury.
Del Hierro Zarzuelo, A; Boto de Los Bueis, A
2016-09-01
To evaluate a series of case that developed iris changes after performing Descemet's stripping automated endothelial keratoplasty (DSAEK). Retrospective study of eyes that developed iris abnormalities, such as pupil ovalisation, iris atrophy, iridocorneal synechiae, mydriatic pupil, and pigmentary changes after performing DSAEK in a tertiary hospital. In a series of the first 32 DSAEK procedures performed, new single or mixed iris alterations were observed in 12 eyes (37.5%). Iris-corneal synechiae were observed in 7 eyes, corectopias in 9 eyes, iris atrophy in 3 cases, and one case developed an areflexic mydriatic pupil. Long-term pigment dispersion at the edge of the lenticule was observed in 12 eyes. The alterations occurred after three months from the surgery. In the evaluation of the associated factors, malignant glaucoma had occurred in 1 case, 2 eyes had required a second surgery, one case by re-DSAEK, and the other one by removing the intraocular lens due to lens opacification. Two cases had a shallow anterior chamber. No relationship was found between the thickness of the peripheral lenticule and the presence of synechiae. Iris changes regarding DSAEK are possible. A discussion is presented on the relationship between increased intraocular pressure due to air in anterior chamber and its relationship with ischaemia and secondary alterations in the iris. Copyright © 2016 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.
Wang, Bailiang; Ye, Zi; Tang, Yihong; Han, Yuemei; Lin, Quankui; Liu, Huihua; Chen, Hao; Nan, Kaihui
Infections after surgery or endophthalmitis are potentially blinding complications caused by bacterial adhesion and subsequent biofilm formation on the intraocular lens. Neither single-function anti-adhesion surface nor contacting killing surface can exhibit ideal antibacterial function. In this work, a novel (2-(dimethylamino)-ethyl methacrylate- co -2-methacryloyloxyethyl phosphorylcholine) (p (DMAEMA- co -MPC)) brush was synthesized by "grafting from" method through reversible-addition fragmentation chain transfer polymerization. 1-Bromoheptane was used to quaternize the p (DMAEMA- co -MPC) brush coating and to endow the surface with bactericidal function. The success of the surface functionalization was confirmed by atomic force microscopy, water contact angle, and spectroscopic ellipsometry. The quaternary ammonium salt units were employed as efficient disinfection that can eliminate bacteria through contact killing, whereas the 2-methacryloyloxyethyl phosphorylcholine units were introduced to suppress unwanted nonspecific adsorption. The functionalized poly(dimethyl siloxane) surfaces showed efficiency in reducing bovine serum albumin adsorption and in inhibiting bacteria adhesion and biofilm formation. The copolymer brushes also demonstrated excellent bactericidal function against gram-positive ( Staphylococcus aureus ) bacteria measured by bacteria live/dead staining and shake-flask culture methods. The surface biocompatibility was evaluated by morphology and activity measurement with human lens epithelial cells in vitro. The achievement of the p (DMAEMA + - co -MPC) copolymer brush coating with nonfouling, bactericidal, and bacteria corpse release properties can be used to modify intraocular lenses.
Farooqui, Javed Hussain; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo
2016-01-01
To compare the accuracy of two different methods of preoperative marking for toric intraocular lens (IOL) implantation, bubble marker versus pendulum marker, as a means of establishing the reference point for the final alignment of the toric IOL to achieve an outcome as close as possible to emmetropia. Toric IOLs were implanted in 180 eyes of 110 patients. One group (55 patients) had preoperative marking of both eyes done with bubble marker (ASICO AE-2791TBL) and the other group (55 patients) with pendulum marker (Rumex(®)3-193). Reference marks were placed at 3-, 6-, and 9-o'clock positions on the limbus. Slit-lamp photographs were analyzed using Adobe Photoshop (version 7.0). Amount of alignment error (in degrees) induced in each group was measured. Mean absolute rotation error in the preoperative marking in the horizontal axis was 2.42±1.71 in the bubble marker group and 2.83±2.31in the pendulum marker group (P=0.501). Sixty percent of the pendulum group and 70% of the bubble group had rotation error ≤3 (P=0.589), and 90% eyes of the pendulum group and 96.7% of the bubble group had rotation error ≤5 (P=0.612). Both preoperative marking techniques result in approximately 3 of alignment error. Both marking techniques are simple, predictable, reproducible and easy to perform.
Chen, Ming
2012-01-01
The aim of this study was to evaluate the accuracy of ORange(®) Gen II (WaveTec Vision, Aliso Viejo, CA). The Surgical Suites, Honolulu, HI. The prospective 28 consecutive cataract surgical cases were selected from 85 cataract surgical cases between December 16, 2010 and February 24, 2011. With the same intraocular lens implantation, the predicted spherical equivalent refraction from IOLMaster(®) (Carl Zeiss AG, Oberkochen, Germany) and ORange Gen II were statistically compared and verified with 1-month postoperative manifest refraction. The data were put into IBM SPSS 19 (SPSS Inc, Chicago, IL) for analysis of variance. Pearson's correlation coefficient was also calculated to evaluate the correlation between the IOLMaster, ORange Gen II, and 1-month postoperative manifest refraction. There were no statistically significant differences in the mean spherical equivalent refraction from the IOLMaster, ORange Gen II, and 1-month postoperative manifest refraction (IOLMaster -0.40 diopters, P = 0.07; ORange Gen II -0.43 diopters, P = 0.16; 1-month refraction -0.41 diopters, P = 0.07). Pearson's correlation study demonstrated that all three were positively correlated (P < 0.05), with the strongest correlation between the ORange Gen II and 1-month postoperative manifest refraction (r = +0.6, P < 0.01). The ORange Gen II can be considered as an alternative method for intraocular lens selection for cataract patients.
Amselem, Luis; Diaz-Llopis, Manuel; Felipe, Adelina; Artigas, Jose M; Navea, Amparo; García-Delpech, Salvador
2008-09-01
To evaluate the efficacy of a standard double intraocular lens (IOL) system (IOL-Vip) in patients with low vision and central scotoma due to macular degeneration and assess the predictability of the residual refraction and magnification. Ophthalmology Department, Hospital General Universitario, Valencia, Spain. This interventional prospective noncomparative case series comprised 13 consecutive surgical procedures in 10 patients with central scotoma. Follow-up was 12 months. Evaluation included the difference between preoperative and postoperative best corrected visual acuity (BCVA), refraction, position of the IOLs, endothelial cell density, and occurrence of postoperative complications. Residual refraction and eye magnification were calculated using a theory developed in a previous study, and the values were compared with the clinical results. The mean BCVA was 1.37 logMAR preoperatively and 0.68 logMAR 1 year postoperatively. The mean best corrected clinical gain was 44%. There was no statistically significant difference between the clinically evaluated and theoretically calculated residual refractions (P = .17). No intraoperative or postoperative complications occurred. Implantation of the double IOL system improved BCVA in patients with low vision due to advanced maculopathy. The results were best in myopic patients (long eyes); patients with hyperopia (short eyes) had high residual refraction. The postoperative clinical gain and residual refraction were predictable, showing the feasibility of implanting a customized double IOL.
Wang, Mengmeng; Corpuz, Christine Carole C; Huseynova, Tukezban; Tomita, Minoru
2016-02-01
To evaluate the influences of preoperative pupil parameters on the visual outcomes of a new-generation multifocal toric intraocular lens (IOL) model with a surface-embedded near segment. In this prospective study, patients with cataract had phacoemulsification and implantation of Lentis Mplus toric LU-313 30TY IOLs (Oculentis GmbH, Berlin, Germany). The visual and optical outcomes were measured and compared preoperatively and postoperatively. The correlations between preoperative pupil parameters (diameter and decentration) and 3-month postoperative visual outcomes were evaluated using the Spearman's rank-order correlation coefficient (Rs) for the nonparametric data. A total of 27 eyes (16 patients) were enrolled into the current study. Statistically significant improvements in visual and refractive performances were found after the implantation of Lentis Mplus toric LU-313 30TY IOLs (P < .05). Statistically significant correlations were present between preoperative pupil diameters and postoperative visual acuities (Rs > 0; P < .05). Patients with a larger pupil always have better postoperative visual acuities. Meanwhile, there was no statistically significant correlation between pupil decentration and visual acuities (P > .05). Lentis Mplus toric LU-313 30TY IOLs provided excellent visual and optical performances during the 3-month follow-up. The preoperative pupil size is an important parameter when this toric multifocal IOL model is contemplated for surgery. Copyright 2016, SLACK Incorporated.
Posterior capsule opacification after implantation of a hydrogel intraocular lens
Hayashi, K; Hayashi, H
2004-01-01
Aim: To compare the degree of posterior capsule opacification (PCO) in eyes with a hydrophilic hydrogel intraocular lens (IOL) with that in eyes with a hydrophobic acrylic IOL. Methods: Ninety five patients underwent a hydrogel IOL implantation in one eye and an acrylic IOL implantation in the opposite eye. The PCO value of these patients was measured using the Scheimpflug videophotography system at 1, 6, 12, 18, and 24 months postoperatively. The rate of neodymium:YAG (Nd:YAG) laser posterior capsulotomy and visual acuity were also evaluated. Results: The mean PCO value in the hydrogel group increased significantly (p<0.0001), while that in the acrylic group did not show significant change. The PCO value in the hydrogel group was significantly greater than that in the acrylic group throughout the follow up period. Kaplan-Meier survival analysis determined that the Nd:YAG capsulotomy rate in the hydrogel group was significantly higher than that in the acrylic group (p<0.0001). Mean visual acuity in the hydrogel group decreased significantly with time (p<0.0001), and became significantly worse than that in the acrylic group at 18 and 24 months postoperatively. Conclusion: Posterior capsule opacification in eyes with a hydrophilic hydrogel IOL is significantly more extensive than that in eyes with a hydrophobic acrylic IOL, and results in a significant impairment of visual acuity. PMID:14736768
Sykakis, Evripidis; Lam, Fook Chang; Georgoudis, Panagiotis; Hamada, Samer; Lake, Damian
2015-01-01
Purpose. To compare the surgical outcomes of staged and combined phacoemulsification with intraocular lens implant (phaco+IOL) and Descemet stripping automated endothelial keratoplasty (DSAEK) in patients with Fuchs' endothelial dystrophy and cataract. Setting. Corneoplastic Unit and Eye Bank, Queen Victoria Hospital, East Grinstead, UK. Methods. Retrospective study of patients who had combined phaco+IOL and DSAEK (group 1) or phaco+IOL followed within 2 months by DSAEK (group 2). Patients who had previous eye surgery or any other ocular comorbidities were excluded. Results. There were 28 eyes in group 1 and 31 in group 2. There were no significant differences in the demographics and corneal tissue characteristics of the two groups. The endothelial disc dislocation and rebubbling rate within 1 week in group 1 was 21.42% and in group 2 was 3.2% (P = 0.04), while the endothelial cell density at 12 months was 1510 ± 433 for group 1 and 1535 ± 482 for group 2 (P = 0.89). The mean 12-month logMAR visual acuity was 0.28 ± 0.24 for group 1 and 0.33 ± 0.15 for group 2 (P = 0.38). Conclusions. Although the combined procedure seems to be associated with a higher complication rate the final outcomes seem to be similar to both methods.
Lam, Fook Chang; Georgoudis, Panagiotis; Hamada, Samer; Lake, Damian
2015-01-01
Purpose. To compare the surgical outcomes of staged and combined phacoemulsification with intraocular lens implant (phaco+IOL) and Descemet stripping automated endothelial keratoplasty (DSAEK) in patients with Fuchs' endothelial dystrophy and cataract. Setting. Corneoplastic Unit and Eye Bank, Queen Victoria Hospital, East Grinstead, UK. Methods. Retrospective study of patients who had combined phaco+IOL and DSAEK (group 1) or phaco+IOL followed within 2 months by DSAEK (group 2). Patients who had previous eye surgery or any other ocular comorbidities were excluded. Results. There were 28 eyes in group 1 and 31 in group 2. There were no significant differences in the demographics and corneal tissue characteristics of the two groups. The endothelial disc dislocation and rebubbling rate within 1 week in group 1 was 21.42% and in group 2 was 3.2% (P = 0.04), while the endothelial cell density at 12 months was 1510 ± 433 for group 1 and 1535 ± 482 for group 2 (P = 0.89). The mean 12-month logMAR visual acuity was 0.28 ± 0.24 for group 1 and 0.33 ± 0.15 for group 2 (P = 0.38). Conclusions. Although the combined procedure seems to be associated with a higher complication rate the final outcomes seem to be similar to both methods. PMID:26064669
Helaly, Hany A; El-Hifnawy, Mohammad A M; Shaheen, Mohamed Shafik; Abou El-Kheir, Amr F
2016-01-01
To evaluate the accuracy of corneal power measurements for intraocular lens (IOL) power calculation after myopic laser in situ keratomileusis (LASIK). The study evaluated 45 eyes with a history of myopic LASIK. Corneal power was measured using manual keratometry, automated keratometry, optical biometry, and Scheimflug tomography. Different hypothetical IOL power calculation formulas were performed for each case. The steepest mean K value was measured with manual keratometry (37.48 ± 2.86 D) followed by automated keratometry (37.31 ± 2.83 D) then optical biometry (37.06 ± 2.98 D) followed by Scheimflug tomography (36.55 ± 3.08). None of the K values generated by Scheimflug tomography were steeper than the measurements from the other 3 instruments. Using equivalent K reading (EKR) 4 mm with the Double-K SRK/T formula, the refractive outcome generated 97.8% of cases within ± 2 D, 80.0% of cases within ± 1 D, and 42.2% of cases within ± 0.5 D. The best combination of formulas was "Shammas-PL + Double-K SRK/T formula using EKR 4 mm." Scheimflug tomography imaging using the Holladay EKR 4 mm improved the accuracy of IOL power calculation in post-LASIK eyes. The best option is a combination of formulas. We recommended the use the combined "Shammas-PL ± Double-K SRK/T formula using EKR 4 mm"h for optical outcomes.
Farid, Marjan; Chak, Garrick; Garg, Sumit; Steinert, Roger F
2014-08-01
To evaluate differences in mean deviation values in automated perimetry in healthy eyes with multifocal compared to monofocal intraocular lens (IOL) implants. Prospective, age-matched, comparative analysis. Single-center, tertiary referral academic practice. A total of 37 healthy eyes in 37 patients with bilateral multifocal (n=22) or monofocal (n=15) IOL implants were studied. INTERVENTION/OBSERVATION PROCEDURE: Humphrey Visual Field 10-2 testing was performed on all patients. Mean deviation (MD) and pattern standard deviation (PSD) numerical values were evaluated and compared between groups. The average MD was -2.84 dB (SD 2.32) for the multifocal IOL group and -0.97 dB (SD 1.58) for the monofocal IOL group (P=.006). There was no significant difference in PSD between the 2 groups (P=.99). Eyes that had the visual field 10-2 testing≥6 months from time of IOL placement showed no improvement in MD when compared to eyes that were tested within 6 months from IOL placement. Multifocal IOL implants cause significant nonspecific reduction in MD values on Humphrey Visual Field 10-2 testing that does not improve with time or neuroadaptation. Multifocal IOL implants may be inadvisable in patients where central visual field reduction may not be tolerated, such as macular degeneration, retinal pigment epithelium changes, and glaucoma. Copyright © 2014 Elsevier Inc. All rights reserved.
Wang, Bailiang; Ye, Zi; Tang, Yihong; Han, Yuemei; Lin, Quankui; Liu, Huihua; Chen, Hao; Nan, Kaihui
2017-01-01
Infections after surgery or endophthalmitis are potentially blinding complications caused by bacterial adhesion and subsequent biofilm formation on the intraocular lens. Neither single-function anti-adhesion surface nor contacting killing surface can exhibit ideal antibacterial function. In this work, a novel (2-(dimethylamino)-ethyl methacrylate-co-2-methacryloyloxyethyl phosphorylcholine) (p (DMAEMA-co-MPC)) brush was synthesized by “grafting from” method through reversible–addition fragmentation chain transfer polymerization. 1-Bromoheptane was used to quaternize the p (DMAEMA-co-MPC) brush coating and to endow the surface with bactericidal function. The success of the surface functionalization was confirmed by atomic force microscopy, water contact angle, and spectroscopic ellipsometry. The quaternary ammonium salt units were employed as efficient disinfection that can eliminate bacteria through contact killing, whereas the 2-methacryloyloxyethyl phosphorylcholine units were introduced to suppress unwanted nonspecific adsorption. The functionalized poly(dimethyl siloxane) surfaces showed efficiency in reducing bovine serum albumin adsorption and in inhibiting bacteria adhesion and biofilm formation. The copolymer brushes also demonstrated excellent bactericidal function against gram-positive (Staphylococcus aureus) bacteria measured by bacteria live/dead staining and shake-flask culture methods. The surface biocompatibility was evaluated by morphology and activity measurement with human lens epithelial cells in vitro. The achievement of the p (DMAEMA+-co-MPC) copolymer brush coating with nonfouling, bactericidal, and bacteria corpse release properties can be used to modify intraocular lenses. PMID:28053527
Kretz, F T A; Son, H; Liebing, S; Tandogan, T; Auffarth, G U
2015-08-01
A clinical evaluation of the functional results and its impact on daily activities of an aspherical, aberration correcting intraocular lens (IOL) was undertaken. Twenty-one patients aged from 50 to 83 years underwent cataract surgery with implantation of the aspheric IOL (Tecnis ZCB00, Abbott Medical Optics). They were evaluated 2 to 4 months after surgery for their subjective satisfaction of vision quality and its impact on performance of daily activities as well as functional results and refractive outcome. Patients were asked to fill out a questionnaire - the Heidelberg DATE (DAily Tasks Evaluation) questionnaire. Significant changes from pre- to postoperative results were found in refraction (p ≤ 0.03), with a mean prediction error of + 0.21 ± 0.43 D. UDVA and CDVA improved significantly (p < 0.01), with a postoperative CDVA of 0.0 logMAR or better in 97.1 % of eyes. All patients would recommend the procedure to a relative or a friend and 93.8 % of patients reported to be satisfied with the outcome. The implantation of the aspheric IOL Tecnis ZCB00 after cataract surgery allows the restoration of visual function, providing an optimised optical quality and a high level of patient satisfaction. Georg Thieme Verlag KG Stuttgart · New York.
Ghosh, Saurabh; Bonshek, Richard; Morgan, Stephen J
2013-01-01
Purpose To report a case of corneal graft failure due to epithelial ingrowth after an uneventful combined Descemet stripping automated endothelial keratoplasty (DSAEK) and phacoemulsification cataract surgery with intraocular lens implant treated successfully with a repeat DSAEK. Methods A 77-year-old male patient underwent combined DSAEK and phacoemulsification with intraocular lens implant implantation for Fuchs’ endothelial dystrophy plus cataract in the right eye. The donor cornea was cut on the Moria ALTK system and introduced using a suture pull-through technique. After an episode of endothelial rejection, the graft failed, with signs suggesting epithelial ingrowth. It was stripped from the host cornea using a Descemet’s membrane stripper, and a Simcoe irrigation-aspiration cannula was used to remove all traces of interface material. The excised lenticule was examined histologically using a hematoxylin and eosin stain. Result The patient regained and maintained excellent visual acuity with no sign of recurrence of epithelial ingrowth. Histopathological evaluation of the donor tissue of the first graft showed epithelial ingrowth on the stromal surface of the graft and very few endothelial cells, in keeping with the diagnosis of graft failure. Conclusion Epithelial ingrowth is a possible cause of endothelial graft failure, but histologically proven cases are rare. Surgical intervention can achieve successful clearance, with the potential for cure and an excellent outcome. PMID:23754868
Kretz, Florian T A; Tandogan, Tamer; Khoramnia, Ramin; Auffarth, Gerd U
2015-01-01
AIM To evaluate the quality of vision in respect to high order aberrations and straylight perception after implantation of an aspheric, aberration correcting, monofocal intraocular lens (IOL). METHODS Twenty-one patients (34 eyes) aged 50 to 83y underwent cataract surgery with implantation of an aspheric, aberration correcting IOL (Tecnis ZCB00, Abbott Medical Optics). Three months after surgery they were examined for uncorrected (UDVA) and corrected distance visual acuity (CDVA), contrast sensitivity (CS) under photopic and mesopic conditions with and without glare source, ocular high order aberrations (HOA, Zywave II) and retinal straylight (C-Quant). RESULTS Postoperatively, patients achieved a postoperative CDVA of 0.0 logMAR or better in 97.1% of eyes. Mean values of high order abberations were +0.02±0.27 (primary coma components) and -0.04±0.16 (spherical aberration term). Straylight values of the C-Quant were 1.35±0.44 log which is within normal range of age matched phakic patients. The CS measurements under mesopic and photopic conditions in combination with and without glare did not show any statistical significance in the patient group observed (P≥0.28). CONCLUSION The implantation of an aspherical aberration correcting monofocal IOL after cataract surgery resulted in very low residual higher order aberration (HOA) and normal straylight. PMID:26309872
Changes in the crystalline lens resulting from insertion of a phakic IOL (ICL) into the porcine eye.
Fujisawa, Kunitoshi; Shimizu, Kimiya; Uga, Shigekazu; Suzuki, Masanobu; Nagano, Koichi; Murakami, Yuuki; Goseki, Hiroko
2007-01-01
Insertion of a phakic IOL offers these advantages: the corneal optical zone is not dissected or resected; preservation of the crystalline lens results in preservation of the accommodation force; and since the phakic IOL is removable, any error or change in refraction can be countered by exchanging it. However, the cause of secondary cataracts has never been clarified or discussed to date. The following ICL lenses were inserted under general anaesthesia into 20 eyes of ten 3-month-old miniature pigs: a minus lens without holes into five eyes, a plus lens in two eyes, a minus lens with four holes around the lens haptics in three eyes, and a minus lens with a central hole in the optic in three eyes; and seven eyes were used as controls. The anterior segments were then photographed 1 week, 1 month and 3 months after surgery. At 3 months after surgery, Evans blue (EB) was infused into the vitreous under general anaesthesia, and after 30 min, the eyeball was enucleated, fixed and examined. In the case of the ICL without holes, the anterior subcapsular opacities were observed in all the eyes, and the anterior surfaces of the crystalline lenses were not stained with EB. Use of the ICL with four holes around the lens haptics resulted in light staining of the anterior surface of the crystalline lens, but the anterior subcapsular opacities observed were mild. As for the ICL with a hole in the centre of the optic, the anterior surface of the crystalline lens was stained and no anterior subcapsular opacities were observed. The results suggested that the insertion of an ICL brings about a change in the dynamics of the intraocular aqueous humour, reducing its circulation to the anterior surface of the crystalline lens. This is considered to cause a metabolic disturbance of the crystalline lens, resulting in anterior subcapsular opacification.
Effect of oxybuprocaine 0.4% in preventing surgically induced miosis.
van Rij, G; Renardel de Lavalette, J G; Baarsma, G S; Jansen, J T
1984-01-01
In a group of 68 patients a double-blind study was performed to assess the effect of preoperative oxybuprocaine 0.4% (Dorsacaine, Novesin) eye drops in comparison with a placebo in preventing surgically induced miosis during extracapsular cataract extraction. One drop of oxybuprocaine 0.4% or placebo was instilled 10 and 5 minutes preoperatively. The pupil diameter was recorded at different stages of the operation. It was found that oxybuprocaine reduced the amount of pupil constriction during the operation significantly as compared with the placebo group, facilitating the removal of lens material and the implantation of an intraocular lens. The effect of oxybuprocaine is considered to be due to anaesthetic action on sensory nerves in the eye, which may inhibit the release of a miotic substance. PMID:6367812
Effect of oxybuprocaine 0.4% in preventing surgically induced miosis.
van Rij, G; Renardel de Lavalette, J G; Baarsma, G S; Jansen, J T
1984-04-01
In a group of 68 patients a double-blind study was performed to assess the effect of preoperative oxybuprocaine 0.4% (Dorsacaine, Novesin) eye drops in comparison with a placebo in preventing surgically induced miosis during extracapsular cataract extraction. One drop of oxybuprocaine 0.4% or placebo was instilled 10 and 5 minutes preoperatively. The pupil diameter was recorded at different stages of the operation. It was found that oxybuprocaine reduced the amount of pupil constriction during the operation significantly as compared with the placebo group, facilitating the removal of lens material and the implantation of an intraocular lens. The effect of oxybuprocaine is considered to be due to anaesthetic action on sensory nerves in the eye, which may inhibit the release of a miotic substance.
Fuchs' dystrophy associated with radial keratotomy: Lamellar or perforating keratoplasty?
Rodriguez-Ausin, P; Antolin-Garcia, D; Santamaria Garcia, L; Blazquez-Fernandez, A-B
2017-05-01
A 70 year-old male patient with a history of radial keratotomy suffering from Fuchs' dystrophy and a cataract. The patient received a two-step surgery: lens phacoemulsification and intraocular lens implant, followed by descemet stripping automated endothelial keratoplasty in both eyes, four months later. There were no complications apart from a recurrent cystoid macular oedema in both eyes. The best corrected visual acuity was 20/40 both eyes, and the patient was satisfied. Descemet stripping automated endothelial keratoplasty may be considered as an alternative to penetrating keratoplasty in the case of endothelial dysfunction and radial keratotomy in patients with no corneal ectasia or significant stromal opacity. Copyright © 2016 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.
[Value the correction of corneal astigmatism in cataract surgery].
Wang, J; Cao, Y X
2018-05-11
The aim of modern micro-incision phacoemulsification combined with foldable intraocular lens implantation and femtosecond laser-assisted cataract surgery is evolving from a simple pursuit of recuperation to a refractive procedure, which involves the correction of ametropia according to preoperative and postoperative refractive conditions, especially corneal astigmatism, in order to achieve the goal of optimized postoperative uncorrected full range of vision. Nowadays, due attention to the effect of preoperative corneal astigmatism, surgery-induced astigmatism and residual astigmatism after operation is lacked, which affect postoperative visual acuity significantly. There are many effective ways to reduce corneal astigmatism after cataract surgery including selecting appropriate size and location of clear corneal incision, employing astigmatism keratotomy and the implantation of Toric intraocular lenses, which need to be appropriately applied and popularized. At the same time, surgical indications, predictability and safety should also be taken into account. (Chin J Ophthalmol, 2018, 54: 321-323) .
NASA Astrophysics Data System (ADS)
Traxler, Lukas; Reutterer, Bernd; Bayer, Natascha; Drauschke, Andreas
2017-04-01
To treat cataract intraocular lenses (IOLs) are used to replace the clouded human eye lens. Due to postoperative healing processes the IOL can displace within the eye, which can lead to deteriorated quality of vision. To test and characterize these effect an IOL can be embedded into a model of the humane eye. One informative measure are wavefront aberrations. In this paper three different setups, the typical double-pass configuration (DP), a single-pass (SP1) where the measured light travels in the same direction as in DP and a single-pass (SP2) with reversed direction, are investigated. All three setups correctly measure the aberrations of the eye, where SP1 is found to be the simplest to set up and align. Because of the lowest complexity it is the proposed method for wavefront measurement in model eyes.
Indaram, Maanasa; VanderVeen, Deborah K
2018-01-01
Advances in surgical techniques allow implantation of intraocular lenses (IOL) with cataract extraction, even in young children. However, there are several challenges unique to the pediatric population that result in greater degrees of postoperative refractive error compared to adults. Literature review of the techniques and outcomes of pediatric cataract surgery with IOL implantation. Pediatric cataract surgery is associated with several sources of postoperative refractive error. These include planned refractive error based on age or fellow eye status, loss of accommodation, and unexpected refractive errors due to inaccuracies in biometry technique, use of IOL power formulas based on adult normative values, and late refractive changes due to unpredictable eye growth. Several factors can preclude the achievement of optimal refractive status following pediatric cataract extraction with IOL implantation. There is a need for new technology to reduce postoperative refractive surprises and address refractive adjustment in a growing eye.
Tognetto, Daniele; Pastore, Marco R; Cirigliano, Gabriella; DʼAloisio, Rossella; Borelli, Massimo; De Giacinto, Chiara
2017-11-16
To investigate long-term intraocular pressure trends after uncomplicated pars plana vitrectomy for idiopathic epiretinal membrane. Three hundred and sixty-eight eyes of 368 consecutive patients were enrolled. Changes in intraocular pressure 1, 3, 6, and 12 months after surgery and during the final follow-up visit were evaluated in vitrectomized eyes and nonvitrectomized fellow eyes. The median follow-up period was 36 months (range 12-92 months). Longitudinal data analysis evidenced a 2.5-mmHg (2.2 mmHg; 2.7 mmHg, 95% confidence interval) statistically significant difference in intraocular pressure 30 days after surgery between treated and fellow untreated eyes, gradually recovering to a not significant 0.2-mmHg (-0.1 mmHg; 0.4 mmHg, 95% confidence interval) difference within 26 months. The incidence of late-onset ocular hypertension was 5.7% (21 over 347, 2%; 12%, 95% confidence interval) without difference between the treated eyes and the group control. No significant difference in the incidence of late-onset ocular hypertension and sex, lens status, or gauge of vitrectomy instruments was detected. Only patient's age was significantly higher (mean difference 4.2 years; 0.1-8.0 years, Monte Carlo, 95% confidence interval) in those who developed late-onset ocular hypertension in the vitrectomized eye. Uncomplicated pars plana vitrectomy for idiopathic epiretinal membrane seems not to increase the risk of late-onset ocular hypertension or open-angle glaucoma development.
An angle-supported foldable phakic intraocular lens for correction of myopia: A five-year follow-up.
Alió, J L; Plaza-Puche, A B; Cavas, F; Yébana Rubio, P; Sala, E
2017-01-01
To evaluate the efficacy and safety of an angle-supported foldable phakic intraocular lens (pIOL) for the correction of moderate to high myopia after 5 years follow-up. Prospective and retrospective, observational, longitudinal, non-randomised consecutive series of cases conducted on a total of 100 eyes of 67 patients with moderate to high myopia implanted with an Acrysof Cachet pIOL (Alcon Laboratories Inc.) with the aim of minimising the refractive error. The ages ranged between 18 to 60years. Uncorrected distance visual acuity (UDVA), manifest refraction, corrected distance visual acuity (CDVA), endothelial cells density, pIOL position, intraocular pressure, and complications were recorded preoperatively and during the 5 year follow-up. Five years after implantation, the mean manifest spherical equivalent refraction reduced significantly from -11.62±3.35 dioptres (D) to -0.33±0.85D. UDVA was 20/20 or better in 5 of 25 cases (20%), and 20/40 or better in 22 cases (88%). CDVA was 20/20 or better in 17 cases (68%), and 20/32 or better in 23 cases (92%) of eyes. The residual refractive error was within ±0.50D of emmetropia in 12 cases (48%), and within ±1.00D in 19 cases (76%). Mean endothelial cell loss at 5 years was 11.8% central, and 13.7% peripheral. Mean endothelium-pIOL distance was 2.11±0.18mm, and mean pIOL-crystalline distance was 0.88±0.20mm. This angle supported pIOL provided a favourable refractive correction and predictability, as well as acceptable safety in patients with moderate to high myopia. Although endothelial cell density decreased over 5years, the results are within the range reported in previous studies with other pIOLs. Copyright © 2016 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.
[Predictability of residual astigmatism after implantation of posterior chamber toric lenses].
Mies, D; Klink, T; Eisenbarth, W; Meyer, L M
2018-01-01
The objective of the study was to examine the predictability of residual astigmatism after cataract surgery and implantation of the posterior chamber aspheric toric lens TECNIS® ZCT, Abott Medical Optic (Ettlingen, Deutschland). The retrospective study included a total of 88 patient eyes undergoing a cataract operation with a toric lens implantation between March 2014 and October 2015. The inclusion criteria were a regular astigmatism of at least 0.75 dpt. Posterior chamber toric lenses (model Tecnis ZCT) were exclusively implanted. Post-surgery check-ups were performed after 1 day, 1 month and 2 months. Main study outcome was best-corrected visual acuity (BCVA), spherical and astigmatic aberration and the difference between expected and actual residual astigmatism after cataract surgery. The median reduction of corneal astigmatism was from -2.50 dpt (±1.06 dpt) to -0.75 dpt (±0.51 dpt) (p ≤ 0.05). The median BCVA increased from 0.37 logMAR (±0.25 logMAR) before surgery to 0.09 logMAR (±0.10 logMAR) after surgery. The spherical equivalent was reduced from +3.50 dpt (±1.11 dpt) (presurgery) to -0.56 dpt (±0.51 dpt) (postsurgery) in hyperopic patients and from -2.44 dpt (±3.03 dpt) to -0.69 dpt (±0.81 dpt) in myopic patients. By using the power vector analysis no significant deviation from the expected target values was observed; however, the median discrepancy between the expected and actual residual astigmatism was -0.50 dpt despite a surgical orientation of the intraocular lens (IOL) within 5° of the desired axis. The IOL showed a median rotation of 3.00° (±4.46°). Implantation of the aspheric toric intraocular lens Tecnis ZCT is a predictable, effective and reproducible tool in cataract surgery to account for regular corneal astigmatis; however, despite an optimal surgical orientation of the toric IOL, a small and rarely a large discrepancy might occur between expected and actual residual astigmatism.
Wong, Robert W; Rhodes, Kyle M
2015-01-01
To describe a case of endophthalmitis after cataract surgery caused by Staphylococcus hominis and two separate colony types of Staphylococcus haemolyticus. Retrospective chart review including ophthalmic examination, intraocular biopsy and cultures, and anterior segment photography. A patient presented with endophthalmitis 1 month after cataract surgery. The patient underwent pars plana vitrectomy with vitreous fluid, aqueous fluid, and lens capsule biopsy with injection of intravitreal antimicrobials with full resolution of the infection. Cultures isolated grew S. hominis and two different colonies of S. haemolyticus, all sensitive to vancomycin. To the best of the authors' knowledge, this is the first case of endophthalmitis due to lens capsule seeding from three different types of bacteria, S. hominis and two different colony types of S. haemolyticus. Prompt diagnosis and treatment can be associated with good visual outcomes.
Auriol, Sylvain; Mahieu, Laurence; Brousset, Pierre; Malecaze, François; Mathis, Véronique
2013-01-01
To evaluate safety of medium-chain triglycerides used as a possible intraocular tamponading agent. A 20-gauge pars plana vitrectomy was performed in the right eye of 28 rabbits. An ophthalmologic examination was performed every week until rabbits were killed. At days 7, 30, 60, and 90, rabbits were killed and the treated eyes were examined macroscopically and prepared for histologic examination. Principal outcome was retinal toxicity evaluated by light and electron microscopy, and secondary outcomes were the presence of medium-chain triglyceride emulsification, inflammatory reactions, and the development of cataract. Histologic examination did not reveal any retinal toxicity. Two cases of moderate emulsification were observed, but in these cases, emulsification was caused by the perioperative injection of the agent and did not increase during the postoperative period. We noted 13 cases of inflammatory reaction in vitreous cavity and no case of inflammatory reaction in anterior chamber. Two eyes developed cataract as a result of perioperative trauma to the lens with the vitreous cutter and not secondary to the presence of medium-chain triglycerides in the vitreous cavity. Medium-chain triglycerides did not induce morphologic evidence of retinal toxicity. The results suggest that medium-chain triglycerides could be a promising alternative intraocular tamponading agent for the treatment of retinal detachments.
Images of intravitreal objects projected onto posterior surface of model eye.
Kawamura, Ryosuke; Shinoda, Kei; Inoue, Makoto; Noda, Toru; Ohnuma, Kazuhiko; Hirakata, Akito
2013-11-01
To try to recreate the images reported by patients during vitreous surgery in a model eye. A fluid-filled model eye with a posterior frosted translucent surface which corresponded to the retina was used. Three holes were made in the model eye through which an endoillumination pipe and intraocular forceps could be inserted. A thin plastic sheet simulating an epiretinal membrane and an intraocular lens (IOL) simulating a dislocated IOL were placed on the retina. The images falling on the posterior surface were photographed from the rear. The images seen through the surgical microscope were also recorded. The images from the rear were mirror images of those seen through the surgical microscope. Intraocular instruments were seen as black shafts from the rear. When the plastic sheet was picked up, the tip of the forceps was seen more sharply on the posterior surface. The images of the dislocated IOL from the posterior were similar to that seen through the surgical microscope, including the yellow optics and blue haptics. Intravitreal objects can form images on the surface of a model eye. Objects located closer to the surface are seen more sharply, and the colour of the objects can be identified. © 2013 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Schallhorn, Julie M; Holiman, Jeffrey D; Stoeger, Christopher G; Chamberlain, Winston
2016-03-01
To evaluate endothelial cell damage after eye bank preparation and passage through 1 of 2 different injectors for Descemet membrane endothelial keratoplasty grafts. Eighteen Descemet membrane endothelial keratoplasty grafts were prepared by Lions VisionGift with the standard partial prepeel technique and placement of an S-stamp for orientation. The grafts were randomly assigned to injection with either a glass-modified Jones tube injector (Gunther Weiss Scientific Glass) or a closed-system intraocular lens injector (Viscoject 2.2; Medicel). After injection, the grafts were stained with the vital fluorescent dye Calcein AM and digitally imaged. The percentage of cell loss was calculated by measuring the area of nonfluorescent pixels and dividing it by the total graft area pixels. Grafts injected using the modified Jones tube injector had an overall cell loss of 27% ± 5% [95% confidence interval, 21%-35%]. Grafts injected using the closed-system intraocular lens injector had a cell loss of 32% ± 8% (95% confidence interval, 21%-45%). This difference was not statistically significant (P = 0.3). Several damage patterns including damage due to S-stamp placement were observed, but they did not correlate with injector type. In this in vitro study, there was no difference in the cell loss associated with the injector method. Grafts in both groups sustained significant cell loss and displayed evidence of graft preparation and S-stamp placement. Improvement in graft preparation and injection methods may improve cell retention.
Baykara, Mehmet; Avci, Remzi
2004-01-01
The results and complications of posterior chamber intraocular lens (IOL) implantation by a 4-point scleral fixation technique are described. Fifty eyes of 47 patients who underwent scleral-fixated IOL implantation were retrospectively evaluated. Twenty-one (42%) eyes had a history of trauma and 29 (58%) eyes had previously undergone cataract surgery. In all cases, IOL implantation by 4-point scleral fixation was performed and the knots of fixation sutures were rotated and buried in the globe. The IOL position was adjusted by suture rotation for best centration. The mean follow-up time was 7 +/- 4 months. Four (8%) eyes had minimal corneal edema preoperatively. Cystoid macular edema was noted in 2 (6.8%) eyes in the cataract surgery group and 8 (38%) eyes in the posttraumatic group. Two (9.5%) eyes in the posttraumatic group had atrophic macular changes and 1 (4.7%) had corneal scarring, which impaired vision. No complications such as knot exposure, tilting of the IOL, decentralization, or endophthalmitis were noted postoperatively. Postoperative mean corrected visual acuity was 0.4 +/- 0.3 in the posttraumatic group and 0.4 +/- 0.2 in the cataract surgery group. The 4-point scleral fixation technique resulted in no serious postoperative complications such as suture exposure and endophthalmitis. Because the knot can be rotated and buried in the globe, knot exposure is less likely to occur. This procedure is more effective than other techniques regarding IOL centralization.
The Enigmatic Cornea and Intraocular Lens Calculations: The LXXIII Edward Jackson Memorial Lecture.
Koch, Douglas D
2016-11-01
To review the progress and challenges in obtaining accurate corneal power measurements for intraocular lens (IOL) calculations. Personal perspective, review of literature, case presentations, and personal data. Through literature review findings, case presentations, and data from the author's center, the types of corneal measurement errors that can occur in IOL calculation are categorized and described, along with discussion of future options to improve accuracy. Advances in IOL calculation technology and formulas have greatly increased the accuracy of IOL calculations. Recent reports suggest that over 90% of normal eyes implanted with IOLs may achieve accuracy to within 0.5 diopter (D) of the refractive target. Though errors in estimation of corneal power can cause IOL calculation errors in eyes with normal corneas, greater difficulties in measuring corneal power are encountered in eyes with diseased, scarred, and postsurgical corneas. For these corneas, problematic issues are quantifying anterior corneal power and measuring posterior corneal power and astigmatism. Results in these eyes are improving, but 2 examples illustrate current limitations: (1) spherical accuracy within 0.5 D is achieved in only 70% of eyes with post-refractive surgery corneas, and (2) astigmatism accuracy within 0.5 D is achieved in only 80% of eyes implanted with toric IOLs. Corneal power measurements are a major source of error in IOL calculations. New corneal imaging technology and IOL calculation formulas have improved outcomes and hold the promise of ongoing progress. Copyright © 2016 Elsevier Inc. All rights reserved.
Farooqui, Javed Hussain; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo
2016-01-01
AIM To compare the accuracy of two different methods of preoperative marking for toric intraocular lens (IOL) implantation, bubble marker versus pendulum marker, as a means of establishing the reference point for the final alignment of the toric IOL to achieve an outcome as close as possible to emmetropia. METHODS Toric IOLs were implanted in 180 eyes of 110 patients. One group (55 patients) had preoperative marking of both eyes done with bubble marker (ASICO AE-2791TBL) and the other group (55 patients) with pendulum marker (Rumex®3-193). Reference marks were placed at 3-, 6-, and 9-o'clock positions on the limbus. Slit-lamp photographs were analyzed using Adobe Photoshop (version 7.0). Amount of alignment error (in degrees) induced in each group was measured. RESULTS Mean absolute rotation error in the preoperative marking in the horizontal axis was 2.42±1.71 in the bubble marker group and 2.83±2.31in the pendulum marker group (P=0.501). Sixty percent of the pendulum group and 70% of the bubble group had rotation error ≤3 (P=0.589), and 90% eyes of the pendulum group and 96.7% of the bubble group had rotation error ≤5 (P=0.612). CONCLUSION Both preoperative marking techniques result in approximately 3 of alignment error. Both marking techniques are simple, predictable, reproducible and easy to perform. PMID:27275425
Kamiya, Kazutaka; Shimizu, Kimiya; Igarashi, Akihito; Kawamorita, Takushi
2015-01-01
This study aimed to investigate the effect of myopic defocus on visual acuity after phakic intraocular lens (IOL) implantation and wavefront-guided laser in situ keratomileusis (wfg-LASIK). Our prospective study comprised thirty eyes undergoing posterior chamber phakic IOL implantation and 30 eyes undergoing wfg-LASIK. We randomly measured visual acuity under myopic defocus after cycloplegic and non-cycloplegic correction. We also calculated the modulation transfer function by optical simulation and estimated visual acuity from Campbell & Green’s retinal threshold curve. Visual acuity in the phakic IOL group was significantly better than that in the wfg-LASIK group at myopic defocus levels of 0, –1, and –2 D (p < 0.001, p < 0.001, and p = 0.02, Mann-Whitney U-test), but not at a defocus of –3 D (p = 0.30). Similar results were also obtained in a cycloplegic condition. Decimal visual acuity values at a myopic defocus of 0, −1, −2, and -3 D by optical simulation were estimated to be 1.95, 1.21, 0.97, and 0.75 in the phakic IOL group, and 1.39, 1.11, 0.94, and 0.71 in the wfg-LASIK group, respectively. From clinical and optical viewpoints, phakic IOL implantation was superior to wfg-LASIK in terms of the postoperative visual performance, even in the presence of low to moderate myopic regression. PMID:25994984
Iris reconstruction using artificial iris prosthesis for management of aniridia.
Mostafa, Yehia S; Osman, Amr A; Hassanein, Dina H; Zeid, Ashraf M; Sherif, Ahmed M
2018-01-01
To discuss the limitations and benefits of the BrightOcular prosthetic artificial iris device in management of aniridia associated with aphakia or cataract. This is a retrospective study including 5 eyes of 4 patients who underwent implantation of the BrightOcular iris prosthesis (Stellar Devices) for total or partial aniridia. The cases included 2 eyes of 1 patient with congenital aniridia associated with congenital cataract and 3 eyes with traumatic aniridia: 1 with subluxated cataractous lens and 2 with aphakia. In all cases, the iris prosthesis was implanted after a 3-piece acrylic intraocular lens was implanted. We evaluated the clinical course with a minimum follow-up period of 6 months, the intraoperative and postoperative complications, and the cosmetic satisfaction of patients. All patients had improved uncorrected distance visual acuity and best-corrected distance visual acuity. All patients had a transient corneal edema that resolved within the first postoperative week. Only the patient with congenital aniridia had a permanent increase in intraocular pressure and developed a band keratopathy throughout a 2-year follow-up period. The prosthesis was well-centered in all eyes except for one case that required scleral suture fixation after 3 months. All patients had a satisfactory cosmetic appearance. BrightOcular iris prosthesis is a safe and useful tool to correct aniridia associated with pseudophakia or aphakia. Being foldable, it is easy to be implanted through a small incision and placed in the ciliary sulcus without sutures when properly sized. Cosmetic results are satisfactory. Sizing methods should be improved.
Kirwan, Clare; Nolan, John M; Stack, Jim; Dooley, Ian; Moore, Johnny; Moore, Tara CB; Beatty, Stephen
2016-01-01
Aim To identify challenges inherent in introducing a toric intraocular lens (IOL) to a non-refractive cataract practice, and evaluate residual astigmatism achieved and its impact on patient satisfaction. Methods Following introduction of a toric IOL to a cataract practice with all procedures undertaken by a single, non-refractive, surgeon (SB), pre-operative, intra-operative and post-operative data was analysed. Attenuation of anticipated post-operative astigmatism was examined, and subjectively perceived visual functioning was assessed using validated questionnaires. Results Median difference vector (DV, the induced astigmatic change [by magnitude and axis] that would enable the initial surgery to achieve intended target) was 0.93D; median anticipated DV with a non-toric IOL was 2.38D. One eye exhibited 0.75D residual astigmatism, compared to 3.8D anticipated residual astigmatism with a non-toric IOL. 100% of respondents reported satisfaction of ≥ 6/10, with 37.84% of respondents entirely satisfied (10/10). 17 patients (38.63%) reported no symptoms of dysphotopsia (dysphoptosia score 0/10), only 3 respondents (6.8%) reported a clinically meaningful level of dysphotopsia (≥ 4/10). Mean post-operative NEI VF-11 score was 0.54 (+/-0.83; scale 0 – 4). Conclusion Use of a toric IOL to manage astigmatism during cataract surgery results in less post-operative astigmatism than a non-toric IOL, resulting in avoidance of unacceptable post-operative astigmatism. PMID:27830188
Simultaneous Bilateral Cataract Surgery in Outreach Surgical Camps
Giles, Kagmeni; Robert, Ebana Steve; Come, Ebana Mvogo; Wiedemann, Peter
2017-01-01
OBJECTIVES The aim of this study was to evaluate the safety and visual outcomes of simultaneous bilateral cataract surgery (SBCS) with intraocular lens implantation performed in outreach surgical eye camps. METHODS The medical records of 47 consecutive patients who underwent simultaneous bilateral small-incision cataract surgery between January 2010 and December 2015 in outreach surgical camps in rural Cameroon were reviewed. The measures included postoperative visual outcomes and intraoperative and postoperative complications. RESULTS Data from 94 eyes of 47 participants (30 men, 17 women; mean age: 60.93 ± 13.58 years, range: 45–80 years) were included in this study. The presented best visual acuity (VA) was less than 3/60 in 100% of the eyes. At the 4-week follow-up, 84.04% of the eyes showed increased VA of 1 line or more (P = .001). Of these, 71 (75.53%) achieved good VA (greater than 6/18). Intraoperative or postoperative complications occurred in 19 (20.21%) eyes. The most serious intraoperative complication was a posterior capsule rupture and vitreous loss (2 patients, 2 eyes). The postoperative complications included a transient elevation in the intraocular pressure (6 eyes), chronic corneal oedema (5 eyes), iris capture (3 eyes), lens decentration (2 eyes), and hyphema (1 eye). No cases of postoperative endophthalmitis were recorded. CONCLUSIONS Under the strict observation of endophthalmitis prophylaxis, SBCS is an option to reduce the cataract blindness backlog in rural areas of developing countries. PMID:28469481
NASA Astrophysics Data System (ADS)
Geniusz, Malwina
2017-09-01
The best treatment for cataract patients, which allows to restore clear vision is implanting an artificial intraocular lens (IOL). The image quality of the lens has a significant impact on the quality of patient's vision. After a long exposure the implant to aqueous environment some defects appear in the artificial lenses. The defects generated in the IOL have different refractive indices. For example, glistening phenomenon is based on light scattering on the oval microvacuoles filled with an aqueous humor which refractive index value is about 1.34. Calcium deposits are another example of lens defects and they can be characterized by the refractive index 1.63. In the presented studies it was calculated how the difference between the refractive indices of the defect and the refractive index of the lens material affects the quality of image. The OpticStudio Professional program (from Radiant Zemax, LLC) was used for the construction of the numerical model of the eye with IOL and to calculate the characteristics of the retinal image. Retinal image quality was described in such characteristics as Point Spread Function (PSF) and the Optical Transfer Function with amplitude and phase. The results show a strong correlation between the refractive indices difference and retinal image quality.
Kamiya, Kazutaka; Shimizu, Kimiya; Igarashi, Akihito; Kitazawa, Yoshihiro; Kojima, Takashi; Nakamura, Tomoaki; Oka, Yoshitaka; Matsumoto, Rei
2018-02-01
To compare the clinical outcomes of posterior chamber phakic intraocular lens implantation with a central hole (Hole Implantable Collamer Lens (ICL), STAAR Surgical) for low-to-moderate myopia and for high myopia. This multicentre retrospective case series comprised 351 eyes of 351 consecutive patients undergoing ICL implantation. Eyes were divided into groups based on preoperative degree of myopia: group 1; 57 eyes, manifest spherical equivalent less than -6 dioptres (D), and group 2; 294 eyes, -6 D or more. Safety, efficacy, predictability, stability and adverse events were compared preoperatively; and at 1 day, 1 week and 1, 3, 6 and 12 months postoperatively, RESULTS: Uncorrected and corrected visual acuities were -0.17±0.14 and -0.21±0.10 logMAR in group 1, and -0.16±0.09 and -0.21±0.08 logMAR in group 2, 1 year postoperatively. In groups 1 and 2, 98% and 99% of eyes were within 1.0 D of the targeted correction. Manifest refraction changes of -0.12±0.34 D (group 1) and -0.18±0.43 D (group 2) occurred from 1 day to 1 year. ICL exchanges were necessary in two eyes (0.7%) in group 2. No vision-threatening complications occurred at any time. The ICL performed well for the correction of both low-to-moderate myopia and high myopia throughout the 1-year observation period. The clinical outcomes of ICL implantation for low-to-moderate myopia are essentially equivalent to those for high myopia. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Brito, Pedro; Salgado-Borges, José; Neves, Helena; Gonzalez-Meijome, José; Monteiro, Manuel
2015-03-01
To study the perception of light distortion after refractive lens exchange (RLE) with diffractive multifocal intraocular lenses (IOLs). Clínica Oftalmológica das Antas, Porto, Portugal. Retrospective comparative study. Refractive lens exchange was performed with implantation of an AT Lisa 839M (trifocal) or 909MP (bifocal toric) IOL, the latter if corneal astigmatism was more than 0.75 diopter (D). The postoperative visual and refractive outcomes were evaluated. A prototype light-distortion analyzer was used to quantify the postoperative light-distortion indices. A control group of eyes in which a Tecnis ZCB00 1-piece monofocal IOL was implanted had the same examinations. A trifocal or bifocal toric IOL was implanted in 66 eyes. The control IOL was implanted in 18 eyes. All 3 groups obtained a significant improvement in uncorrected distance visual acuity (UDVA) (P < .001) and corrected distance visual acuity (CDVA) (P = .001). The mean uncorrected near visual acuity (UNVA) was 0.123 logMAR with the trifocal IOL and 0.130 logMAR with the bifocal toric IOL. The residual refractive cylinder was less than 1.00 D in 86.7% of cases with the toric IOL. The mean light-distortion index was significantly higher in the multifocal IOL groups than in the monofocal group (P < .001), although no correlation was found between the light-distortion index and CDVA. The multifocal IOLs provided excellent UDVA and functional UNVA despite increased light-distortion indices. The light-distortion analyzer reliably quantified a subjective component of vision distinct from visual acuity; it may become a useful adjunct in the evaluation of visual quality obtained with multifocal IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Evaluation of a contact lens-embedded sensor for intraocular pressure measurement.
Twa, Michael D; Roberts, Cynthia J; Karol, Huikai J; Mahmoud, Ashraf M; Weber, Paul A; Small, Robert H
2010-08-01
To evaluate a novel contact lens-embedded pressure sensor for continuous measurement of intraocular pressure (IOP). Repeated measurements of IOP and ocular pulse amplitude (OPA) were recorded in 12 eyes of 12 subjects in sitting and supine positions using 3 configurations of the dynamic contour tonometer: slit-lamp mounted (DCT), hand-held (HH), and contact lens-embedded sensor (CL). The IOP and OPA for each condition were compared using repeated measures ANOVA and the 95% limits of agreement were calculated. The sitting IOP (mean and 95% CI) for each configuration was DCT: 16.3 mm Hg (15.6 to 17.1 mm Hg), HH: 16.6 mm Hg (15.6 to 17.6 mm Hg), and CL: 15.7 mm Hg (15 to 16.3 mm Hg). The sitting OPA for each configuration was DCT: 2.4 mm Hg (2.1 to 2.6 mm Hg), HH: 2.4 mm Hg (2.1 to 2.7 mm Hg), and CL: 2.1 mm Hg (1.8 to 2.3 mm Hg). Supine IOP and OPA measurements with the CL and HH sensors were both greater than their corresponding sitting measurements, but were significantly less with the CL sensor than the HH sensor. The mean difference and 95% Limits of Agreement were smallest for the DCT and CL sensor comparisons (0.7+/-3.9 mm Hg) and widest for the CL and HH sensors (-1.9+/-7.25 mm Hg); these wider limits were attributed to greater HH measurement variability. The CL sensor was comparable to HH and DCT sensors with sitting subjects and is a viable method for measuring IOP and OPA. Supine measurements of IOP and OPA were greater than sitting conditions and were comparatively lower with the CL sensor. HH measurements were more variable than CL measurements and this influenced the Limits of Agreement for both sitting and supine conditions.
Rabie, Hossein Mohammad; Malekifar, Parviz; Javadi, Mohammad Ali; Roshandel, Danial; Esfandiari, Hamed
2017-08-01
To review our experience with crystalline lens extraction and iris claw Artisan IOL implantation in patients with lens subluxation secondary to Marfan syndrome. A retrospective analysis of 12 eyes of 9 patients with lens subluxation due to Marfan syndrome who underwent crystalline lens removal and Artisan IOL (Ophtec, Groningen, Netherlands) implantation. A questionnaire of pre- and post-operative data, including demographics, pre- and postoperative comorbidities and complications was completed. Patients were evaluated for visual outcome and occurrence of complications. Uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), and spherical equivalents (SE) were compared before and after lens extraction and IOL insertion. The mean age of the participants was 30.03 ± 15.02 years, and mean post-operative follow-up time was 44.5 ± 16.4 months. Mean BCVA also showed a significant improvement from 0.5 ± 0.3 at the baseline to 0.2 ± 0.2 post-operatively (P = 0.006). SE changed significantly from -11.38 ± 1.99 preoperatively to -0.45 ± 1.65 post-operatively (P = 0.003). All eyes had the IOL implanted at desired position. Post-operative complications were retinal detachment in one case and IOL dislocation in another patient. No other complication such as ocular hypertension, angle abnormalities, clinical cystoids macular edema, and corneal decompensation was observed during the follow-up period. Artisan IOL implantation after lens extraction appears to be an attractive alternative for optical correction in cases of Marfan syndrome with ectopia lentis. It confers a significant improvement in visual acuity with reasonable risk profile.
Hull, C C; Crofts, N C
1996-03-01
The Beer-Lambert law has been used to determine the total attenuation coefficient, mu t, of three hard and three soft contact lens materials. The three hard contact lens materials were PMMA, Polycon II and Boston IV whereas the 3 soft materials were chosen with differing water contents of 38, 55 and 70%, respectively. The total attenuation coefficients of all six materials were obtained from measurements of the axial transmission at 632.8 nm of a series of plano powered lenses varying in axial thickness from 0.5 to 3.5 mm. The value of the total attenuation coefficient depends on both scattering and absorption and hence PMMA and Boston IV, which both incorporated a handling tint, showed significantly higher values (P < 0.0001) of mu t (0.562 +/- 0.010 mm-1 and 0.820 +/- 0.008 mm-1, respectively) than Polycon II (mu t = 0.025 +/- 0.005 mm-1). A comparison between Polycon II and the three hydrated soft contact lens materials showed a significant increase (P < 0.02) in the total attenuation coefficients for the 38% and 55% water content materials, and a weakly significant increase for the 70% water content soft lens material (P < 0.1). On the assumption that the absorption coefficients of these four materials are approximately constant, then this change would be due to an increase in the scattering coefficient of the material and could contribute to an increase in intraocular scatter. No significant difference (P > 0.5) was found between any of the hydrated soft contact lens materials tested.
Early changes in morphology and intraocular pressure by size of clear corneal incision.
Cheng, Bing; Liu, Yi; Liu, Yizhi; Xie, Bin Bin; Xi, Lei; Yang, Ye
2011-06-01
We compared changes in morphology and intraocular pressure (IOP) induced by clear 2.2-mm and 3.0-mm corneal incisions in a cohort of patients with cataracts. In 160 eyes (from 70 men and 90 women at the Ophthalmic Center of Sun Yat-sen University), optical coherence tomography and tonometry were performed at 1, 5, and 24 hours after cataract surgery. The main outcome measures were IOP, postoperative changes in Descemet membrane detachment (DMD), healing of the surgical incision, and inflammation of the anterior chamber. Five hours after surgery, patients with 2.2-mm and 3.0-mm incisions had lower IOPs (P < 0.017) as measured by noncontact tonometry, but the difference was significant only among patients with grade V cataracts (2.2 mm, 12.6 ± 1.2 mm Hg; 3.0 mm, 14.5 ± 0.9 mm Hg, P < 0.05). The incidence of endothelial gap at 24 hours after surgery was significantly higher in the 2.2-mm (50%) versus 3.0-mm (11.1%) group of patients with grade V cataracts (P < 0.05). The incidence of DMD at 5 hours was also significantly higher in the 2.2-mm group (75%) than in the 3.0-mm group (22.2%) only among patients with this grade (P < 0.05). Incision width made no difference among patients with grade I-IV lens nuclei; but among those with grade V, 3.0-mm incisions had significantly less endothelial gaping, less DMD, and higher mean IOPs. For these patients, smaller incisions may not be optimal, and eyes may be especially vulnerable within 5 hours of surgery.
Effects of a blue light-filtering intraocular lens on driving safety in glare conditions.
Gray, Rob; Hill, Warren; Neuman, Brooke; Houtman, Diane; Potvin, Richard
2012-05-01
To evaluate whether the previously established benefit of blue light-filtering intraocular lenses (IOLs) when driving in glare conditions is maintained in patients previously implanted with a blue light-filtering toric IOL. Department of Applied Psychology, Arizona State University, Mesa, Arizona, USA. Comparative case series. The study comprised patients with a blue light-filtering toric IOL (test IOL) or an ultraviolet (UV)-only filtering nontoric IOL (control IOL). All patients had good visual acuity and a valid driver's license. While wearing best spherocylindrical correction, patients performed left-turn maneuvers in front of oncoming traffic in a driving simulator. The safety margin was defined as the time to collision less the time taken to turn at an intersection with oncoming traffic. Measures were repeated with a glare source simulating low-angle sun conditions (daytime driving). Of the 33 evaluable patients, 18 had a test IOL and 15 had a control IOL. In the presence of glare, patients with test IOLs had significantly greater safety margins (mean 2.676 seconds ± 0.438 [SD]) than patients with control IOLs (mean 2.179 ± 0.343 seconds) and significantly lower glare susceptibility (P<.05). In no-glare and glare conditions, patients with test IOLs had significantly lower glare susceptibility than patients with control IOLs. The blue light-filtering toric IOL produced a significantly greater reduction in glare disability than the UV-only filtering nontoric IOL and increased the ability of drivers to safely execute left turns in low-sun conditions. Dr. Houtman is an employee of Alcon Laboratories, Inc. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Huang, Guofu; Gonzalez, Eduardo; Lee, Roland; Chen, Yi-Chun; He, Mingguang; Lin, Shan C
2012-01-01
To evaluate anterior chamber biometric factors associated with the degree of angle widening and intraocular pressure (IOP) reduction after phacoemulsification. University of California, San Francisco, California, USA. Case series. Anterior chamber parameters obtained by anterior segment coherence tomography were compared preoperatively and 3 months postoperatively. Measurements included the angle opening distance 500 μm anterior to the scleral spur (AOD500), trabecular-iris space area 500 μm from the scleral spur (TISA500), iris curvature (I-Curv), anterior chamber angle (ACA), trabecular-iris space area, anterior chamber volume, anterior chamber width, and lens vault (LV). The study enrolled 73 eyes. The mean patient age was 77.45 years ± 7.84 (SD); 65.75% of patients were women. From preoperatively to 3 months postoperatively, the mean AOD500 increased significantly (0.254 ± 0.105 to 0.433 ± 0.108 mm) and the mean IOP decreased significantly (14.97 ± 3.35 to 12.62 ± 3.37 mm Hg) (P<.001). The reduction in IOP was correlated with the increase in AOD500 (r = 0.240, P=.041) and preoperative LV (r = 0.235, P=.045). After adjusting for related factors, AOD500 widening was positively correlated with LV (β = 0.458, P=.044) and I-Curv (β = 0.235, P=.043) and negatively correlated with preoperative TISA500 (β = -0.269, P=.025) and ACA (β = -0.919, P=.027). Surgically induced AOD widening was significantly correlated with anterior chamber biometric factors. Preoperative LV appears to be a significant factor in angle widening and IOP reduction after phacoemulsification. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Nd: YAG photodisruptors. American Academy of Ophthalmology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
Nd: YAG laser surgery can cut lens capsule, vitreous and capsular membranes, strands, and adhesions, and the iris within the surgically unopened eye, thereby avoiding infection, wound leaks, and other complications of conventional intraocular surgery. The technique has found its most widespread use in performing posterior capsulotomies after extracapsular cataract surgery. It has an extremely low complication rate when used in the anterior segment and is a preferred alternative to surgical discission. The uncertainties regarding its safety in creating iridotomies in phakic eyes have lessened with its extensive use in patients with pupillary-block glaucoma. However, caution is urged in othermore » applications in phakic eyes. Following each Nd: YAG laser procedure, the eye should be monitored for elevation of intraocular pressure during the first two hours, and for retinal tears, retinal detachment, or cystoid macular edema during the first month after the procedure. Uncertainties persist regarding the circumstances under which the laser in its current configuration should be used in the vitreous cavity.« less
Hassenstein, A; Niemeck, F; Giannakakis, K; Klemm, M
2017-06-01
Perforating keratoplasty shows good morphological results with a clear cornea; however, a limiting factor is often the resulting astigmatism, which cannot be corrected with either glasses or contact lenses (CL) in up to 20% of the patients. We retrospectively investigated 15 patients after pseudophakic perforating keratoplasty, who received implantation of toric add-on intraocular lenses (IOL) to correct astigmatism. The mean preoperative astigmatism of 6.5 diopter (dpt) could be reduced to a mean postoperative value of 1.0 dpt. The mean visual acuity could be improved from a preoperative value of sc <0.05 (cc 0.6) to a postoperative value of sc 0.4 (cc 0.63). There were no complications except for one case of a lens extension tear. Based on our good experiences we now provide toric add-on IOL to all patients with pseudophakic perforating keratoplasty when this cannot be corrected or only insufficiently corrected by conservative methods.
What was Glaucoma Called Before the 20th Century?
Leffler, Christopher T.; Schwartz, Stephen G.; Giliberti, Francesca M.; Young, Matthew T.; Bermudez, Dennis
2015-01-01
Glaucoma involves a characteristic optic neuropathy, often with elevated intraocular pressure. Before 1850, poor vision with a normal eye appearance, as occurs in primary open-angle glaucoma, was termed amaurosis, gutta serena, or black cataract. Few observers noted palpable hardness of the eye in amaurosis. On the other hand, angle-closure glaucoma can produce a green or gray pupil, and therefore was called, variously, glaucoma (derived from the Greek for glaucous, a nonspecific term connoting blue, green, or light gray) and viriditate oculi. Angle closure, with palpable hardness of the eye, mydriasis, and anterior prominence of the lens, was described in greater detail in the 18th and 19th centuries. The introduction of the ophthalmoscope in 1850 permitted the visualization of the excavated optic neuropathy in eyes with a normal or with a dilated greenish-gray pupil. Physicians developed a better appreciation of the role of intraocular pressure in both conditions, which became subsumed under the rubric “glaucoma”. PMID:26483611
Capsule-Fixated Intraocular Lens Implantation in Small Pupil Cases.
Schojai, Merita; Schultz, Tim; Burkhard Dick, H
2017-08-01
To describe a new technique for implantation of capsule-fixated intraocular lenses (IOLs) (FEMTIS; Oculentis, Berlin, Germany) in patients with small pupils. In 4 eyes with small pupils, an anterior capsule-fixated IOL was implanted into the capsular bag after femtosecond laser treatment. The two large and two small flaps of the IOL were elevated to the front of the iris and the anterior capsule. Finally, the iris was flipped over the flaps to ensure a fixation of the capsule inside of the capsulotomy. In all cases, the implantation of anterior capsule-fixated IOLs was possible. No complications occurred during surgery or within the first months after surgery. With the described technique, capsulefixated IOLs can be implanted in eyes with small pupil easily and safely. This type of IOL has great potential to improve the refractive outcome by better prediction of the postoperative IOL position and eliminating IOL rotation after cataract surgery. [J Refract Surg. 2017;33(8):568-570.]. Copyright 2017, SLACK Incorporated.
Seuthe, A-M; Szurman, P; Boden, K T
2017-11-01
We report on a patient with postsurgical cystoid macular edema (CME) after phacoemulsification and multifocal intraocular lens (MIOL) implantation. At first, there was a very good reaction to intravitreal triamcinolone, inducing complete regression of the edema without increasing intraocular pressure (IOP). One year later the patient suffered from retinal detachment and was treated with vitrectomy, laser, and gas tamponade. Afterward, he developed macular pucker with edema. After surgical treatment with pucker peeling and intravitreal triamcinolone, the patient showed a steroid response and an increase IOP. Postoperatively, there was a recurrence of CME. A coincidental administration of a steroid injection intramuscularly by the general practitioner achieved a prompt reduction of the CME without increasing IOP. This case shows that an initially good reaction to triamcinolone without increasing IOP does not rule out a future steroid response, and that a potential treatment option for CME in patients with a known steroid response could consist of intramuscularly injected steroids.
BMP signaling is required for development of the ciliary body.
Zhao, Shulei; Chen, Qin; Hung, Fang-Cheng; Overbeek, Paul A
2002-10-01
The ciliary body in the eye secretes aqueous humor and glycoproteins of the vitreous body and maintains the intraocular pressure. The ciliary muscle controls the shape of the lens through the ciliary zonules to focus the image onto the retina. During embryonic development, the ciliary epithelium is derived from the optic vesicle, but the molecular signals that control morphogenesis of the ciliary body are unknown. We report that lens-specific expression of a transgenic protein, Noggin, can block BMP signaling in the mouse eye and result in failure in formation of the ciliary processes. Co-expression of transgenic BMP7 restores normal development of the ciliary epithelium. Ectopic expression of Noggin also promotes differentiation of retinal ganglion cells. These results indicate that BMP signaling is required for development of the ciliary body and may also play a role in regulation of neuronal differentiation in the developing eye.
Unusual Internal Astigmatism Due to Severe Capsule Contraction Syndrome.
Zéboulon, Pierre; Gatinel, Damien
2018-01-01
To describe a case of severe capsule contraction syndrome causing significant astigmatism due to intraocular lens (IOL) folding. Case report. Capsule fibrosis and contraction resulted in bending of the hydrophilic IOL along its long axis. Anterior Nd:YAG capsulotomy resolved the situation and restored the patient's visual acuity. Hydrophilic IOLs are more susceptible to capsule contraction due to the increased flexibility of highly hydrated materials. They should be avoided in patients at risk of capsule contraction to prevent ocular complications. [J Refract Surg. 2018;34(1):65-67.]. Copyright 2018, SLACK Incorporated.
Features of optical surfaces of multifocal diffractive-refractive eye lenses
NASA Astrophysics Data System (ADS)
Lenkova, G. A.
2017-09-01
This paper considers shape features of the surface structures of multifocal intraocular lenses (IOLs), which, unlike bifocal IOLs, generate additional foci or extends the depth of focus, which not only corrects near and far vision but also provides good vision at intermediate distances. Expansion of the field of clear vision is achieved due to the effects of diffraction, interference, and refraction (change in the radius of curvature of the lens surface). The optical characteristics of the most famous multifocal IOLs (trifocal and quadrafocal lenses and lenses with extended focal area) are given.
Sophocleous, Sophocles
2016-05-05
Phacoemulsification cataract surgery with small clear corneal incision (CCI) is the standard of care for cataract treatment. Self-sealing, clear corneal wounds have been found to be stable and able to withstand high pressures. Nevertheless, there are a few cases published describing patients with previous cataract surgery and manually performed CCI who sustained blunt trauma with associated wound dehiscence, iris disinsertion and expulsion through the wound. The case described here demonstrates an eye that had traumatic aniridia post-blunt trauma, while the intraocular lens and the rest of the ocular structures remained intact. 2016 BMJ Publishing Group Ltd.
Kim, Kyeong Hwan; Kim, Wan Soo
2015-09-01
To compare the efficacy and safety of iris fixation with scleral fixation in surgical repositioning of dislocated intraocular lenses (IOLs). Retrospective, consecutive, comparative interventional case series. setting: Referral hospital. Seventy-eight consecutive patients who underwent surgical repositioning of dislocated intraocular lenses using suturing to the sclera or iris. Forty-four eyes of 44 patients underwent scleral fixation and 35 eyes of 34 patients underwent iris fixation of dislocated intraocular lenses. Visual acuity, refractive stability, operation time, and perioperative complications, including recurrence of IOL dislocation. Corrected distance visual acuity (CDVA) improved significantly 1 month postoperatively in both groups (P < .01 each), and remained stable for 12 months. One week postoperatively, however, CDVA improved significantly in the scleral fixation (P = .040) but not in the iris fixation (P = .058) group. The amount of refractive error significantly diminished 1 day after surgery (P = .028 in the scleral fixation and P = .046 in the iris fixation group). For the astigmatic components, Jackson crossed cylinders equivalent to conventional cylinders of positive power at axes of 0 degrees (J0) and 45 degrees (J45), J45 differed significantly in the scleral fixation and iris fixation groups (P = .009), whereas J0 was similar (P > .05). Operation time was significantly shorter (P = .0007), while immediate postoperative inflammation was significantly more severe (P = .001), in the iris fixation than in the scleral fixation group. Recurrence rates were similar (P > .05), but the mean time to recurrence was significantly shorter in the iris fixation than in the scleral fixation group (P = .031). Iris fixation and scleral fixation techniques had similar efficacy in the repositioning of dislocated intraocular lenses. Although operation time was shorter for iris fixation, it had several disadvantages, including induced astigmatism, immediate postoperative inflammation, earlier recurrence, and less stable refraction. Copyright © 2015 Elsevier Inc. All rights reserved.
The effects of two different types of bandage contact lenses on the healthy canine eye.
Braus, Barbara Katharina; Riedler, Daniela; Tichy, Alexander; Spergser, Joachim; Schwendenwein, Ilse
2018-02-06
To compare two types of bandage contact lenses on the healthy canine eye. Six healthy Beagles. Two different types of bandage contact lenses (single sized human silicone contact lens 'PureVision 2' (Bausch & Lomb Incorporated, Rochester, NY, USA) and specially designed veterinary hydrogel contact lens 'AcriVet Pat D' (Bausch & Lomb Incorporated) were placed in 12 eyes of healthy Beagle dogs. Retention times and the effects of the lenses regarding irritation of the eye, changes in tear production, impact of contact lenses on tonometric readings, and cytologic and microbiological alterations of the canine eye were investigated. Mean retention times for veterinary hydrogel lenses with special dimensions were significantly shorter (2 days) than for one size human silicon lenses (8.8 days). Irritation scores were overall low for both types of lenses apart from one human lens causing severe irritation and keratoconjunctivitis as a sequel to folding and displacement. Tear production remained stable in human contact lenses. Intraocular pressure readings with a contact lens in place were only slightly altered; the most accurate readings were obtained through a human lens with an applanation tonometer. Cytology revealed a slight, nonsignificant increase in neutrophilic granulocytes with both types of lenses; the microflora did not change significantly. Human silicone lenses have significantly longer retention times and are less expensive than veterinary hydrogel lenses. In regard to irritation, bacterial growth and inflammation, both types of lenses can be recommended for use in canine eyes. © 2018 American College of Veterinary Ophthalmologists.
Crystalline lens dislocation secondary to bacterial endogenous endophthalmitis.
Sangave, Amit; Komati, Rahul; Weinmann, Allison; Samuel, Linoj; Desai, Uday
2017-09-01
To present an unusual case of endogenous endophthalmitis secondary to Group A streptococcus (GAS) that resulted in dislocation of the crystalline lens. An immunocompetent 51-year-old man presented to the emergency room (ER) with upper respiratory infection (URI) symptoms and painful right eye. He was diagnosed with URI and viral conjunctivitis and discharged on oral azithromycin and polytrim eyedrops. He returned to the ER 30 h later with sepsis and findings consistent with endophthalmitis, including light perception only vision. Ophthalmology was consulted at this time and an emergent vitreous tap and injection was performed. Both blood and vitreous cultures grew an atypical non-hemolytic variant of GAS ( Streptococcus pyogenes ). The primary source of infection was presumed to be secondary to pharyngitis or cutaneous dissemination. Final vision in the affected eye was no light perception, likely from a combination of anterior segment scarring, posterior segment damage, and hypotony. Interestingly, head computed tomography (CT) at the initial ER presentation showed normal lens position, but repeat CT at re-presentation revealed posterior dislocation of the lens. Endophthalmitis secondary to GAS has been sparsely reported in the literature, and this case highlights a unique clinical presentation. We suspect that this atypical non-hemolytic strain may have evaded detection on initial pharyngeal cultures. Additionally, we hypothesize that GAS-mediated protease release resulted in breakdown of the zonular fibers and subsequent lens dislocation. Ophthalmologists should be aware of GAS and its devastating intraocular manifestations.
[Complications of a voluminous congenital ciliary body cyst].
Kottler, Ulrike B; Schwenn, Oliver
2002-09-01
Multiple cysts of iris and ciliary body may cause many complications such as acute or chronic angle closure glaucoma. We present a boy with multiple congenital cysts of the iris pigment epithelium and a voluminous cyst of the unpigmented ciliary body epithelium of the right eye. This resulted in lenticular astigmatism, concomitant strabismus divergens and subsequently to anisometropia. The voluminous cyst (8 x 12 mm in diameter) was folded around the lens, reached the optic axis and resulted in displacement of the lens and contact between the iris and the corneal endothelium from 6.30 to 11. After puncture and partial resection of the cyst at the age of 8 months the boy developed a subcapsular multivesicular cataractic clouding of the temporal lens and a progredient myopia (up to - 14.0/- 2.0/0 degrees ); in contrast the left eye was hyperopic (+ 3.5/- 3.75/0 degrees ). The lens was subluxated superonasally due to congenital damage of the zonular fibres. Because development of visual acuity seemed limited by these determinants (20/200 at the right eye), cataract surgery with posterior capsulorhexis, anterior vitrectomy, and implantation of a capsular tension ring and posterior chamber intraocular lens was performed at the age of nearly five. Actually, there is an orthotropia, best corrected visual acuity in the distance of 20/32 in the right and 20/20 in the left eye; binocular vision is somewhat restricted. Usually congenital cysts are clinically not very relevant; occasionally surgical intervention is required to ensure adequate development of visual acuity.
Introduction of Lens-angle Reconstruction Surgery in Rabbit Eyes
Kim, Min Hee; Hwang, Ho Sik; Park, Kyoung Jin; Hwang, Je Hyung
2014-01-01
Purpose In this study, we examined the stability of the lens-angle supporter (LAS) for accommodation restoration by comparing intraocular lens (IOL) location, after-cataract and ciliary body damage after cataract surgery in rabbits. Methods Eight rabbits were divided into experimental and control groups of four rabbits each. Phacoemulsification and irrigation and aspiration were performed in all rabbits. This was followed by an LAS and IOL insertion in the four experimental rabbits. In the four control rabbits, only an IOL insertion was performed. Six months after the surgery, the location of the IOL, the conditions of the lens capsule and ciliary body were evaluated using a slitl-amp examination and Miyake-Apple view. Results For the experimental group, the ultrasound biomicroscope results showed normal LAS and IOL positioning in all four cases. According to the slitlamp examination and Miyake-Apple view, the IOL was positioned at the center, with less after-cataract and damage to the ciliary body. For the control group, ultrasound biomicroscope results indicated a higher IOL position than normal, as well as a single case of IOL decentering. According to the slit-lamp examination and Miyake-Apple view, the IOL was decentered with more severe after-cataract and ciliary body damage. Conclusions The LAS has the potential to maintain a stable IOL position while producing less after-cataract when used in lens-angle reconstruction for correction of presbyopia. Moreover, LAS implantation incurs less damage to the ciliary body. PMID:25435752
Graessl, Andreas; Muhle, Maximilian; Schwerter, Michael; Rieger, Jan; Oezerdem, Celal; Santoro, Davide; Lysiak, Darius; Winter, Lukas; Hezel, Fabian; Waiczies, Sonia; Guthoff, Rudolf F; Falke, Karen; Hosten, Norbert; Hadlich, Stefan; Krueger, Paul-Christian; Langner, Soenke; Stachs, Oliver; Niendorf, Thoralf
2014-05-01
This study was designed to examine the feasibility of ophthalmic magnetic resonance imaging (MRI) at 7 T using a local 6-channel transmit/receive radiofrequency (RF) coil array in healthy volunteers and patients with intraocular masses. A novel 6-element transceiver RF coil array that makes uses of loop elements and that is customized for eye imaging at 7 T is proposed. Considerations influencing the RF coil design and the characteristics of the proposed RF coil array are presented. Numerical electromagnetic field simulations were conducted to enhance the RF coil characteristics. Specific absorption rate simulations and a thorough assessment of RF power deposition were performed to meet the safety requirements. Phantom experiments were carried out to validate the electromagnetic field simulations and to assess the real performance of the proposed transceiver array. Certified approval for clinical studies was provided by a local notified body before the in vivo studies. The suitability of the RF coil to image the human eye, optical nerve, and orbit was examined in an in vivo feasibility study including (a) 3-dimensional (3D) gradient echo (GRE) imaging, (b) inversion recovery 3D GRE imaging, and (c) 2D T2-weighted fast spin-echo imaging. For this purpose, healthy adult volunteers (n = 17; mean age, 34 ± 11 years) and patients with intraocular masses (uveal melanoma, n = 5; mean age, 57 ± 6 years) were investigated. All subjects tolerated all examinations well with no relevant adverse events. The 6-channel coil array supports high-resolution 3D GRE imaging with a spatial resolution as good as 0.2 × 0.2 × 1.0 mm, which facilitates the depiction of anatomical details of the eye. Rather, uniform signal intensity across the eye was found. A mean signal-to-noise ratio of approximately 35 was found for the lens, whereas the vitreous humor showed a signal-to-noise ratio of approximately 30. The lens-vitreous humor contrast-to-noise ratio was 8, which allows good differentiation between the lens and the vitreous compartment. Inversion recovery prepared 3D GRE imaging using a spatial resolution of 0.4 × 0.4 × 1.0 mm was found to be feasible. T2-weighted 2D fast spin-echo imaging with the proposed RF coil afforded a spatial resolution of 0.25 × 0.25 × 0.7 mm. This work provides valuable information on the feasibility of ophthalmic MRI at 7 T using a dedicated 6-channel transceiver coil array that supports the acquisition of high-contrast, high-spatial resolution images in healthy volunteers and patients with intraocular masses. The results underscore the challenges of ocular imaging at 7 T and demonstrate that these issues can be offset by using tailored RF coil hardware. The benefits of such improvements would be in positive alignment with explorations that are designed to examine the potential of MRI for the assessment of spatial arrangements of the eye segments and their masses with the ultimate goal to provide imaging means for guiding treatment decisions in ophthalmological diseases.
[The effects of glycemic control on ophthalmic refraction in diabetic patients].
Li, Hai-yan; Luo, Guo-chun; Guo, Jiang; Liang, Zhen
2010-10-01
To evaluate effects of glycemic control on refraction in diabetic patients. Twenty newly diagnosed diabetic patients were included in this study. The random blood glucose, glycosylated hemoglobin A1c (HbA1c) levels, fasting C-peptide and postprandial 2 h C-peptide levels were measured before treatment. The patients with random blood glucose ≥ 12.0 mmol/L and HbA1c ≥ 10.0% were selected. Refraction, intraocular pressure, radius of the anterior corneal curvature, depth of the anterior chamber, lens thickness, vitreous length, and axial length were measured on admission and at the end of week 1, 2, 3 and 4 during glycaemic control. A transient hyperopic change occurred in all the patients receiving glycemic control with a mean maximum hyperopic changes of 1.6 D (0.50 D ∼ 3.20 D). There was a positive correlation between the magnitude of the maximum hyperopic changes and the HbA1c levels on admission (r = 0.84, P < 0.05). There was a positive correlation between the magnitude of the maximum hyperopic changes and the daily rate of blood glucose reduction over the first 7 days of the treatment (r = 0.53, P < 0.05). There was no significant correlation between the magnitude of the maximum hyperopic changes and the levels of random blood glucose on admission. No significant correlation was observed between the maximum hyperopic changes and fasting C-peptide or postprandial 2 h C-peptide. There were no significant correlations between the magnitude of the maximum hyperopic changes and age, blood press, body mass index, triglyceride, total cholesterol, low-density lipoprotein or high-density lipoprotein. No significant changes were observed in the intraocular pressure, radius of the anterior corneal curvature, depth of the anterior chamber, lens thickness, vitreous length and axial length during glycemic control. Transient hyperopic changes occur after glycemic control in diabetic patients with severe hyperglycaemia. The degrees of transient hyperopia are highly dependent on HbA1c levels before treatment and the rate of reduction of glucose level over the first 7 days of treatment. This is probably due to the decrease of refractive power by lens hydration, not morphological change of lens.
de Castro, Alberto; Rosales, Patricia; Marcos, Susana
2007-03-01
To measure tilt and decentration of intraocular lenses (IOLs) with Scheimpflug and Purkinje imaging systems in physical model eyes with known amounts of tilt and decentration and patients. Instituto de Optica Daza de Valdés, Consejo Superior de Investigaciones Científicas, Madrid, Spain. Measurements of IOL tilt and decentration were obtained using a commercial Scheimpflug system (Pentacam, Oculus), custom algorithms, and a custom-built Purkinje imaging apparatus. Twenty-five Scheimpflug images of the anterior segment of the eye were obtained at different meridians. Custom algorithms were used to process the images (correction of geometrical distortion, edge detection, and curve fittings). Intraocular lens tilt and decentration were estimated by fitting sinusoidal functions to the projections of the pupillary axis and IOL axis in each image. The Purkinje imaging system captures pupil images showing reflections of light from the anterior corneal surface and anterior and posterior lens surfaces. Custom algorithms were used to detect the Purkinje image locations and estimate IOL tilt and decentration based on a linear system equation and computer eye models with individual biometry. Both methods were validated with a physical model eye in which IOL tilt and decentration can be set nominally. Twenty-one eyes of 12 patients with IOLs were measured with both systems. Measurements of the physical model eye showed an absolute discrepancy between nominal and measured values of 0.279 degree (Purkinje) and 0.243 degree (Scheimpflug) for tilt and 0.094 mm (Purkinje) and 0.228 mm (Scheimpflug) for decentration. In patients, the mean tilt was less than 2.6 degrees and the mean decentration less than 0.4 mm. Both techniques showed mirror symmetry between right eyes and left eyes for tilt around the vertical axis and for decentration in the horizontal axis. Both systems showed high reproducibility. Validation experiments on physical model eyes showed slightly higher accuracy with the Purkinje method than the Scheimpflug imaging method. Horizontal measurements of patients with both techniques were highly correlated. The IOLs tended to be tilted and decentered nasally in most patients.
Tanihara, H; Honjo, M; Inatani, M; Honda, Y; Ogino, N; Ueno, S; Negi, A; Ichioka, H; Mizoguchi, T; Matsumura, M; Nagata, M
1997-10-01
The authors previously reported the usefulness of trabeculotomy ab externo for the treatment of primary open-angle glaucoma in adult patients. In an attempt to elucidate the long-term risk-to-benefit ratio of this surgical modality in combination with cataract surgery, the authors conducted a retrospective study of the surgical effects and complications of a triple procedure: phacoemulsification, implantation (of an intraocular lens), and trabeculotomy (PIT). The authors conducted a retrospective study of patients treated with PIT at multiple hospitals. Intraocular pressure (IOP) and visual function data were obtained from patients after PIT as an initial surgical treatment in cases where antiglaucoma medications failed to resolve uncontrolled IOP (higher than 21 mm Hg). Included in this study were 96 eyes of 64 patients with primary open-angle glaucoma and coexisting cataract. The mean follow-up period was 22.6 +/- 14.7 months (range 3-56 months). In 94 (98%) of the 96 eyes, the IOP was well controlled, having achieved a level of 21 mm Hg or lower at the final examinations. The mean preoperative IOP of the 33 eyes that underwent the triple procedure using a single flap method (PIT-I) was 24.3 +/- 3.9 mm Hg, with an average of 2.1 +/- 1.1 medications. At the final examinations, the mean IOP had dropped to 16.0 +/- 1.2 mm Hg, with an average of 1.2 +/- 1.2 medications. The mean preoperative IOP of the 63 eyes that underwent the triple procedure using a double flap method (PIT-II) was 26.2 +/- 6.2 mm Hg, with an average of 1.9 +/- 1.2 medications. At the final examination, the mean IOP for this group was 15.6 +/- 2.9 mm Hg, with an average of 1.0 +/- 0.9 medications. The long-term results from this multicenter study showed that the triple procedure, PIT, can be useful and effective as an initial surgical treatment for open-angle glaucoma in glaucoma patients with coexisting cataract.
An evaluation of novel vital dyes for intraocular surgery.
Haritoglou, Christos; Yu, Alice; Freyer, Wolfgang; Priglinger, Siegfried G; Alge, Claudia; Eibl, Kirsten; May, Christian A; Welge-Luessen, Ulrich; Kampik, Anselm
2005-09-01
To evaluate systematically the staining characteristics and safety of potential new dyes for intraocular surgery. Six dyes were included in the investigation: light green SF (LGSF) yellowish, E68, bromophenol blue (BPB), Chicago blue (CB), rhodamine 6G, rhodulinblau-basic 3 (RDB-B3). All dyes were dissolved and diluted in a balanced saline saline solution. The light-absorbing properties of each dye were measured at a concentration of 0.05% between 200 and 1000 nm. Staining characteristics were examined by staining lens capsule tissue and epiretinal membranes (ERMs), removed intraoperatively, with dye concentrations of 1.0%, 0.5%, 0.2%, and 0.05%. Enucleated porcine eyes (postmortem time, 9 hours) were also stained. Dye-related toxicity was evaluated by a colorimetric test (MTT) measuring the inhibition of retinal pigment epithelium (RPE) cell proliferation (ARPE-19 and primary human RPE cells, passages 3-6). Cell viability was also quantified based on a two-color fluorescence cell-viability assay. Dyes were investigated in concentrations of 0.2% and 0.02%. All dyes investigated in this study stained human lens capsules, removed intraoperatively; ERMs, peeled during macular pucker surgery; and enucleated porcine eyes, depending on the concentration applied. The long-wavelength absorption maximum of the dyes was within the range of 527 to 655 nm at concentrations of 0.05%. Rhodamine G6 and RDB-B3 showed adverse effects on ARPE-19 cell proliferation at a concentration of 0.2% and were excluded from further investigation in primary RPE cells. The remaining four dyes showed no toxic effect on ARPE-19 and primary RPE cell proliferation at concentrations of 0.2% and 0.02%. Cell viability was affected by LGSF yellowish (0.2%) and CB (0.2% and 0.02%). Two dyes (E68 and BPB) showed no relevant toxicity in vitro. The systematic evaluation of dyes for intraocular use seems mandatory. In this study four dyes were identified with effective staining characteristics, with two of these dyes having no detectable toxic effect on RPE cells in vitro.
Design and evaluation of an intraocular B-scan OCT-guided 36-gauge needle
NASA Astrophysics Data System (ADS)
Shen, Jin H.; Joos, Karen M.
2015-03-01
Optical coherence tomography imaging is widely used in ophthalmology and optometry clinics for diagnosing retinal disorders. External microscope-mounted OCT operating room systems have imaged retinal changes immediately following surgical manipulations. However, the goal is to image critical surgical maneuvers in real time. External microscope-mounted OCT systems have some limitations with problems tracking constantly moving intraocular surgical instruments, and formation of absolute shadows by the metallic surgical instruments upon the underlying tissues of interest. An intraocular OCT-imaging probe was developed to resolve these problems. A disposable 25-gauge probe tip extended beyond the handpiece, with a 36-gauge needle welded to a disposable tip with its end extending an additional 3.5 mm. A sealed 0.35 mm diameter GRIN lens protected the fiber scanner and focused the scanning beam at a 3 to 4 mm distance. The OCT engine was a very high-resolution spectral-domain optical coherence tomography (SDOCT) system (870 nm, Bioptigen, Inc. Durham, NC) which produced 2000 A-scan lines per B-scan image at a frequency of 5 Hz with the fiber optic oscillations matched to this frequency. Real-time imaging of the needle tip as it touched infrared paper was performed. The B-scan OCT-needle was capable of real-time performance and imaging of the phantom material. In the future, the B-scan OCT-guided needle will be used to perform sub-retinal injections.
Navarro, Rodrigo M.; Machado, Leonardo M.; Maia, Ossires; Wu, Lihteh; Farah, Michel E.; Magalhaes, Octaviano; Arevalo, J. Fernando; Maia, Mauricio
2015-01-01
Purpose. To determine the efficacy of 23-gauge pars plana vitrectomy (PPV) for symptomatic posterior vitreous detachment (PVD) on visual acuity (VA) and quality after multifocal intraocular lenses (IOLs). Methods. In this prospective case series, patients who developed symptomatic PVD and were not satisfied with visual quality due to floaters and halos after multifocal IOL implantation underwent PPV. Examinations included LogMAR uncorrected visual acuity (UCVA), intraocular pressure, biomicroscopy, and indirect ophthalmoscopy at baseline and 1, 7, 30, and 180 days postoperatively. Ultrasonography and aberrometry were performed. The Visual Functioning Questionnaire 25 (VFQ-25) was administered preoperatively and at 30 days postoperatively. Both the postoperative UCVA and questionnaire results were compared to preoperative findings using the Wilcoxon test. Results. Sixteen eyes of 8 patients were included. VA significantly improved from 0.17 to 0.09 postoperatively (P = 0.017). All patients reported improvement of halos, glare, and floaters. VFQ-25 scores significantly improved in general vision (P = 0.023), near activities (P = 0.043), distance activities (P = 0.041), mental health (P = 0.011), role difficulties (P = 0.042), and driving (P = 0.016). Conclusion. PPV may increase UCVA and quality of vision in patients with bilateral multifocal IOLs and symptomatic PVD. Larger studies are advised. PMID:26504590
Sowka, Joseph; Girgis, Nadine
2010-09-01
Angle closure most commonly occurs in older hyperopic patients as a result of primary relative pupil block. Less frequently, angle closure occurs in highly myopic patients with conditions other than primary relative pupil block. This report presents the diagnosis, pathophysiologic mechanism, and management of a patient with both high myopia and bilateral advanced phacomorphic angle-closure glaucoma caused by isolated spherophakia. A 40-year-old asymptomatic man with very high myopic astigmatism presented with chronic angle closure and an intraocular pressure of 42 mmHg in both eyes. Additionally there was a nonmyopic fundus and 24-mm axial length, with a clear crystalline lens protruding through the pupillary plane in each eye, confirmed by B-scan ultrasonography. Gonioscopy and A-scan and B-scan ultrasonography identified the pathogenesis of intraocular pressure elevation, angle closure, and high myopia to be lenticular in origin. Initial medical therapy and subsequent laser iridotomy relieved the pupil block angle closure and successfully lowered intraocular pressure. Angle closure can occur in highly myopic eyes. Careful gonioscopy and ultrasonography can lead to the correct diagnosis and tailored management for these eyes. Phacomorphic angle-closure glaucoma from spherophakia is associated with Weill-Marchesani syndrome as well as a few other uncommon syndromes. Isolated pseudophakia is a rarely reported cause of phacomorphic angle closure. Copyright 2010 American Optometric Association. Published by Elsevier Inc. All rights reserved.
Surgical Management of Iatrogenic Pigment Dispersion Glaucoma.
Mierlo, Camille Van; Pinto, Luis Abegão; Stalmans, Ingeborg
2015-01-01
Iatrogenic pigment dispersion syndrome generally originates from a repetitive, mechanical trauma to the pigmented posterior epithelium of the iris. This trauma can arise after intraocular surgery, most commonly due to an abnormal contact between the intraocular lens (IOL) and the iris. Whether surgical removal of this primary insult can lead to a successful intraocular pressure (IOP) control remains unclear. Case-series. Patients with IOP elevation and clinical signs of pigment dispersion were screened for a diagnosis of iatrogenic IOL-related pigment dispersion. Three patients in which the IOL or the IOL-bag complex caused a pigment dispersion through a repetitive iris chafing were selected. In two cases, replacement of a sulcus-based single-piece IOL (patient 1) or a sub-luxated in-the-bag IOL (patient 2) by an anterior-chamber (AC) iris-fixed IOL led to a sustained decrease in IOP. In the third case, extensive iris atrophy and poor anatomical AC parameters for IOL implantation precluded further surgical intervention. IOL-exchange appears to be a useful tool in the management of iatrogenic pigment dispersion glaucoma due to inappropriate IOL implantation. This cause-oriented approach seems to be effective in controlling IOP, but should be offered only if safety criteria are met. How to cite this article: Van Mierlo C, Abegao Pinto L, Stalmans I. Surgical Management of Iatrogenic Pigment Dispersion Glaucoma. J Curr Glaucoma Pract 2015;9(1):28-32.
Hayashi, Ken; Manabe, Shin-Ichi; Hayashi, Hideyuki
2009-12-01
To compare visual acuity from far to near, contrast visual acuity, and acuity in the presence of glare (glare visual acuity) between an aspheric diffractive multifocal intraocular lens (IOL) with a low addition (add) power (+3.0 diopters) and a monofocal IOL. Hayashi Eye Hospital, Fukuoka, Japan. This prospective study comprised patients having implantation of an aspheric diffractive multifocal ReSTOR SN6AD1 IOL with a +3.0 D add (multifocal group) or a monofocal AcrySof IQ SN60WF IOL (monofocal group). Visual acuity from far to near distances, contrast acuity, and glare acuity were evaluated 3 months postoperatively. Each IOL group comprised 64 eyes of 32 patients. For monocular and binocular visual acuity, the mean uncorrected and distance-corrected intermediate acuity at 0.5 m and the near acuity at 0.3 m were significantly better in the multifocal group than in the monofocal group (P=.0035); distance and intermediate acuity at 0.7 m and 1.0 m were similar between the 2 groups. No significant differences were observed between groups in contrast acuity and glare acuity under photopic and mesopic conditions. Furthermore, no significant correlation was found between all-distance acuity and pupil diameter or between visual acuity and IOL decentration and tilt. The diffractive multifocal IOL with a low add power provided significantly better intermediate and near visual acuity than the monofocal IOL. Contrast sensitivity with and without glare was reduced with the multifocal IOL, and all-distance visual acuity was independent of pupil diameter and IOL displacement.
Guarnieri, Adriano; Moreno-Montañés, Javier; Sabater, Alfonso L; Gosende-Chico, Inmaculada; Bonet-Farriol, Elvira
2013-11-01
To analyze the changes in incision sizes after implantation of a toric intraocular lens (IOL) using 2 methods. Department of Ophthalmology, Clínica Universidad de Navarra, Pamplona, Spain. Prospective case series. Coaxial phacoemulsification and IOL implantation through a 2.2 mm clear corneal incision using a cartridge injector were performed. Wound-assisted or cartridge-insertion techniques were used to implant the IOLs. The results were analyzed according to IOL spherical and cylindrical powers. Corneal hysteresis (CH) and the corneal resistance factor (CRF) were measured and evaluated based on the changes in incision size. Incision size increased in 30 (41.7%) of 72 eyes in the wound-assisted group and 71 (98.6%) of 72 eyes in the cartridge-insertion group. The mean incision size after IOL implantation was 2.27 mm ± 0.06 (SD) and 2.37 ± 0.05 mm, respectively (P<.01). The final incision size and IOL spherical power in the wound-assisted technique group (P=.02) and the cartridge-insertion technique group (P=.03) were correlated significantly; IOL toricity was not (P=.19 and P=.28, respectively). The CH and CRF values were not correlated with the final incision size. The final incision size and the changes in incision size after IOL implantation were greater with the cartridge-insertion technique than with the wound-assisted technique. The increase was related to IOL spherical power in both groups but not to IOL toricity. Corneal biomechanical properties were not correlated with the final incision size. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
[Quantitative evaluation of acrylic and silicone intraocular lenses with a sharp optic edge design].
Rabsilber, T M; Reuland, A J; Entz, B B; Holzer, M P; Limberger, I J; Auffarth, G U
2006-01-01
At the Department of Ophthalmology, Heidelberg, Germany, posterior capsule opacification (PCO) of a silicone and an acrylic intraocular lens (IOL) with a sharp optic edge design was evaluated. In a prospective study either the AMO ClariFlex silicone IOL or the Sensar AR40e hydrophobic acrylic IOL were implanted in 47 patients following uneventful phacoemulsification. Mean patient age was 76.2+/-7.8 (ClariFlex) and 73.4+/-12.9 years (AR40e), respectively. The mean follow-up time was 19.7+/-5.34 in the ClariFlex and 21.9+/-1.89 months in the AR40e group. PCO development was evaluated postoperatively using the EPCO 2000 analysis software (scale 0-4). Areas of interest were the total IOL optic, the central 3-mm zone as well as the capsulorhexis. In both groups, all patients achieved a BCVA of 20/32 (AR40e) and 20/25 (ClariFlex), respectively. There was a very low incidence of PCO development with a mean EPCO score of 0.07+/-0.2 (ClariFlex and 0.15+/-0.2 (AR40e). Within the 3-mm zone and the capsulorhexis, there was a tendency for even lower EPCO scores in both groups. We calculated a statistically significant difference for the two lens materials for all investigated IOL areas (Wilcoxon's test, p<0.05). Both IOLs with a sharp edge design showed good functional results, a stable position in the capsular bag as well as a low incidence of PCO development. However, the silicone IOL showed statistically significantly lower PCO scores.
Müftüoğlu, İlkay Klç; Akova, Yonca Aydn; Egrilmez, Sait; Yilmaz, Suzan Guven
2016-03-01
To evaluate the results of toric intraocular lens (IOL) implantation in patients with cataract and postpenetrating keratoplasty astigmatism. Seven eyes of 7 patients with cataract and more than 3.5 diopters (D) astigmatism following penetrating keratoplasty were included in this retrospective case series study. All of the eyes underwent phacoemulsification and Acrysof toric IOL (t5-t9) implantation at least 6 months later than the complete suture removal. Corrected visual acuity (CVA), manifest astigmatism, the keratometry measurements, and complications were assessed. The mean preoperative CVA significantly increased (0.7±0.3 [range: 0.3-1.3] logMAR to 0.1±0.04 [range: 0.05-0.15] logMAR; P<0.05) at mean 8.71±4.11 months after the surgery. The mean preoperative corneal astigmatism and the average manifest refractive astigmatism at the last visit were 5.4±0.9 D (range: 4.25-7 D) and 1.6±0.6 D (range: 0.5-2.5 D), respectively. The mean attempted cylinder correction at spectacle plane was 4.3±0.9 D (range: 2.4-4.7 D) whereas the mean cylinder correction was 4.6±0.5 D (range: 3.9-5.9 D), showing a slightly tendency for overcorrection. All eyes (100%) were within 1 D of predicted residual astigmatism. No complication occurred during the follow-up. Toric IOL implantation seems to be an effective, predictable, and safe procedure in patients with cataract formation and high astigmatism after penetrating keratoplasty.