Sample records for universal joint wrist

  1. Kinematics of Hooke universal joint robot wrists

    NASA Technical Reports Server (NTRS)

    Mckinney, William S., Jr.

    1988-01-01

    The singularity problem associated with wrist mechanisms commonly found on industrial manipulators can be alleviated by redesigning the wrist so that it functions as a three-axis gimbal system. This paper discussess the kinematics of gimbal robot wrists made of one and two Hooke universal joints. Derivations of the resolved rate motion control equations for the single and double Hooke universal joint wrists are presented using the three-axis gimbal system as a theoretical wrist model.

  2. Forward and inverse kinematics of double universal joint robot wrists

    NASA Technical Reports Server (NTRS)

    Williams, Robert L., II

    1991-01-01

    A robot wrist consisting of two universal joints can eliminate the wrist singularity problem found on many individual robots. Forward and inverse position and velocity kinematics are presented for such a wrist having three degrees of freedom. Denavit-Hartenberg parameters are derived to find the transforms required for the kinematic equations. The Omni-Wrist, a commercial double universal joint robot wrist, is studied in detail. There are four levels of kinematic parameters identified for this wrist; three forward and three inverse maps are presented for both position and velocity. These equations relate the hand coordinate frame to the wrist base frame. They are sufficient for control of the wrist standing alone. When the wrist is attached to a manipulator arm; the offset between the two universal joints complicates the solution of the overall kinematics problem. All wrist coordinate frame origins are not coincident, which prevents decoupling of position and orientation for manipulator inverse kinematics.

  3. The double universal joint wrist on a manipulator: Solution of inverse position kinematics and singularity analysis

    NASA Technical Reports Server (NTRS)

    Williams, Robert L., III

    1992-01-01

    This paper presents three methods to solve the inverse position kinematics position problem of the double universal joint attached to a manipulator: (1) an analytical solution for two specific cases; (2) an approximate closed form solution based on ignoring the wrist offset; and (3) an iterative method which repeats closed form position and orientation calculations until the solution is achieved. Several manipulators are used to demonstrate the solution methods: cartesian, cylindrical, spherical, and an anthropomorphic articulated arm, based on the Flight Telerobotic Servicer (FTS) arm. A singularity analysis is presented for the double universal joint wrist attached to the above manipulator arms. While the double universal joint wrist standing alone is singularity-free in orientation, the singularity analysis indicates the presence of coupled position/orientation singularities of the spherical and articulated manipulators with the wrist. The cartesian and cylindrical manipulators with the double universal joint wrist were found to be singularity-free. The methods of this paper can be implemented in a real-time controller for manipulators with the double universal joint wrist. Such mechanically dextrous systems could be used in telerobotic and industrial applications, but further work is required to avoid the singularities.

  4. 21 CFR 888.3800 - Wrist joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint metal/polymer semi-constrained... Wrist joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. A wrist joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a wrist joint...

  5. 21 CFR 888.3800 - Wrist joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Wrist joint metal/polymer semi-constrained... Wrist joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. A wrist joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a wrist joint...

  6. 21 CFR 888.3800 - Wrist joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Wrist joint metal/polymer semi-constrained... Wrist joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. A wrist joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a wrist joint...

  7. 21 CFR 888.3800 - Wrist joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Wrist joint metal/polymer semi-constrained... Wrist joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. A wrist joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a wrist joint...

  8. 21 CFR 888.3800 - Wrist joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Wrist joint metal/polymer semi-constrained... Wrist joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. A wrist joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a wrist joint...

  9. Comparison of dominant hand range of motion among throwing types in baseball pitchers.

    PubMed

    Wang, Lin-Hwa; Kuo, Li-Chieh; Shih, Sheng-Wen; Lo, Kuo-Cheng; Su, Fong-Chin

    2013-08-01

    Previous research on baseball pitchers' wrists, elbows, and should joints contributes to our understanding of pitchers' control over delicate joint motion and ball release. However, limited research on forearm, wrist, and hand joints prevents full comprehension of the throwing mechanism. The present descriptive laboratory study quantifies angular performances of hand and wrist joints while pitching breaking balls, including fastballs, curveballs and sliders, among pitchers with different skill levels. Nineteen baseball pitchers performed required pitching tasks (10 from university and 9 from high school). A three-dimensional motion analysis system collected pitching motion data. The range of joint motion in the wrist and proximal interphalangeal (PIP) and metacarpophalangeal (MP) joints of the index and middle fingers were compared among fastballs, curveballs and sliders. Thirteen reflective markers were placed on selected anatomic landmarks of the wrist, middle and index fingers of the hand. Wrist flexion angle in the pitching acceleration phase was larger in fastballs (20.58±4.07°) and sliders (22.48±5.45°) than in curveballs (9.08±3.03°) (p = .001). The flexion angle of the PIP joint was significantly larger in curveballs (38.5±3.8°) than in fastballs (30.3±4.8°) and sliders (30.2±4.5°) (p=.004) of the middle finger. Abduction angle of MP joint on the middle finger was significantly larger in curveballs (15.4 ±3.6°) than in fastballs (8.9±1.2°) and sliders (6.9±2.9°) (p=.001) of the middle finger, and the abduction angle of index finger was significantly larger in sliders (13.5±15.0°) than in fastballs (7.2 ±2.8°) (p=.007). Hand and wrist motion and grip types affect the relative position between fingers and ball, which produces different types of baseball pitches. A larger extension angle of the wrist joint and the coordination of middle and index fingers are crucial when pitching a fastball. Abduction and flexion movement on the MP joint of the middle finger are important for a curveball. MP joint abduction and flexion movement of the index finger produce sliders. Understanding the control mechanism in a throwing hand can help improve training protocols in either injury prevention or performance improvement for baseball pitchers. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. 21 CFR 888.3790 - Wrist joint metal constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint metal constrained cemented prosthesis... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3790 Wrist joint metal constrained cemented prosthesis. (a) Identification. A wrist joint metal constrained cemented prosthesis is a...

  11. 21 CFR 888.3790 - Wrist joint metal constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Wrist joint metal constrained cemented prosthesis... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3790 Wrist joint metal constrained cemented prosthesis. (a) Identification. A wrist joint metal constrained cemented prosthesis is a...

  12. 21 CFR 888.3780 - Wrist joint polymer constrained prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint polymer constrained prosthesis. 888... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3780 Wrist joint polymer constrained prosthesis. (a) Identification. A wrist joint polymer constrained prosthesis is a device made of...

  13. 21 CFR 888.3780 - Wrist joint polymer constrained prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Wrist joint polymer constrained prosthesis. 888... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3780 Wrist joint polymer constrained prosthesis. (a) Identification. A wrist joint polymer constrained prosthesis is a device made of...

  14. 21 CFR 888.3780 - Wrist joint polymer constrained prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Wrist joint polymer constrained prosthesis. 888... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3780 Wrist joint polymer constrained prosthesis. (a) Identification. A wrist joint polymer constrained prosthesis is a device made of...

  15. 21 CFR 888.3780 - Wrist joint polymer constrained prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Wrist joint polymer constrained prosthesis. 888... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3780 Wrist joint polymer constrained prosthesis. (a) Identification. A wrist joint polymer constrained prosthesis is a device made of...

  16. 21 CFR 888.3780 - Wrist joint polymer constrained prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Wrist joint polymer constrained prosthesis. 888... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3780 Wrist joint polymer constrained prosthesis. (a) Identification. A wrist joint polymer constrained prosthesis is a device made of...

  17. Immediate effects of different treatments for the wrist joints of subdominant hands, using electromechanical reaction time.

    PubMed

    Hu, Chunying; Huang, Qiuchen; Yu, Lili; Zhou, Yue; Gu, Rui; Cui, Yao; Ge, Meng; Xu, Yanfeng; Liu, Jianfeng

    2016-08-01

    [Purpose] The aim of this study was to examine the immediate effects of muscle strength training and neuromuscular joint facilitation distal resistance training on wrist joints by using electromechanical reaction time. [Subjects and Methods] The subjects were 12 healthy young people (24.2 ± 3.1 years, 169.7 ± 6.5 cm, 65.3 ± 12.6 kg). Two kinds of isotonic contraction techniques were applied on the wrist joint: the wrist joint extension muscle strength training and the wrist joint extension pattern of neuromuscular joint facilitation. The electromechanical reaction time, premotor time, and motor time of the left upper limb were measured before and after each intervention session of muscle strength training and neuromuscular joint facilitation. [Results] The neuromuscular joint facilitation group showed significant shortening of the electromechanical reaction time and motor time after the intervention. [Conclusion] These results suggest that the electromechanical reaction time and motor time of the wrist joint can be improved by neuromuscular joint facilitation together with proximal resistance training, which can be used as a new form of exercise for improving the functions of subdominant hand wrist joints.

  18. Evaluation of effects of different treatments for the wrist joints of subdominant hands using joint proprioception and writing time.

    PubMed

    Hu, Chunying; Huang, Qiuchen; Yu, Lili; Hu, Yue; Rongming, Xia; Li, Zhou; Xiaojiao, Fu; Gu, Rui; Cui, Yao; Ge, Meng; Xu, Yanfeng; Liu, Jianfeng

    2016-05-01

    [Purpose] The purpose of this study was to examine immediate effects of strength training and NJF distal resistance training in wrist joints by using writing time and evaluation of proprioception using the JPE test. [Subjects and Methods] The subjects were 12 young healthy people (24.2 ± 3.1 y, 169.7 ± 6.5 cm, 65.3 ± 12.6 kg). Two isotonic contraction techniques were applied on the wrist joint: wrist joint extension muscle strength training (MST) and the wrist joint extension pattern of NJF. The uppercase English alphabet writing time and joint position errors of the left upper limb were measured before and after one intervention session of MST and NJF. [Results] The decrease in errors in wrist extension angle repetition and the writing time represented the improvement resulting from NJF. [Conclusion] This result suggests that the subdominant hands wrist joint proprioception and writing function can be improved by NJF together with proximal resistance training.

  19. Evaluating the Ergonomic Benefit of a Wrist Brace on Wrist Posture, Muscle Activity, Rotational Stiffness, and Peak Shovel-Ground Impact Force During a Simulated Tree-Planting Task.

    PubMed

    Sheahan, Peter J; Cashaback, Joshua G A; Fischer, Steven L

    2017-09-01

    Background Tree planters are at a high risk for wrist injury due to awkward postures and high wrist loads experienced during each planting cycle, specifically at shovel-ground impact. Wrist joint stiffness provides a measure that integrates postural and loading information. Objective The purpose of this study was to evaluate wrist joint stiffness requirements at the instant of shovel-ground impact during tree planting and determine if a wrist brace could alter muscular contributions to wrist joint stiffness. Method Planters simulated tree planting with and without wearing a brace on their planting arm. Surface electromyography (sEMG) from six forearm muscles and wrist kinematics were collected and used to calculate muscular contributions to joint rotational stiffness about the wrist. Results Wrist joint stiffness increased with brace use, an unanticipated and negative consequence of wearing a brace. As a potential benefit, planters achieved a more neutrally oriented wrist angle about the flexion/extension axis, although a less neutral wrist angle about the ulnar/radial axis was observed. Muscle activity did not change between conditions. Conclusion The joint stiffness analysis, combining kinematic and sEMG information in a biologically relevant manner, revealed clear limitations with the interface between the brace grip and shovel handle that jeopardized the prophylactic benefits of the current brace design. This limitation was not as evident when considering kinematics and sEMG data independently. Application A neuromechanical model (joint rotational stiffness) enhanced our ability to evaluate the brace design relative to kinematic and sEMG parameter-based metrics alone.

  20. Automatic Quantification of Radiographic Wrist Joint Space Width of Patients With Rheumatoid Arthritis.

    PubMed

    Huo, Yinghe; Vincken, Koen L; van der Heijde, Desiree; de Hair, Maria J H; Lafeber, Floris P; Viergever, Max A

    2017-11-01

    Objective: Wrist joint space narrowing is a main radiographic outcome of rheumatoid arthritis (RA). Yet, automatic radiographic wrist joint space width (JSW) quantification for RA patients has not been widely investigated. The aim of this paper is to present an automatic method to quantify the JSW of three wrist joints that are least affected by bone overlapping and are frequently involved in RA. These joints are located around the scaphoid bone, viz. the multangular-navicular, capitate-navicular-lunate, and radiocarpal joints. Methods: The joint space around the scaphoid bone is detected by using consecutive searches of separate path segments, where each segment location aids in constraining the subsequent one. For joint margin delineation, first the boundary not affected by X-ray projection is extracted, followed by a backtrace process to obtain the actual joint margin. The accuracy of the quantified JSW is evaluated by comparison with the manually obtained ground truth. Results: Two of the 50 radiographs used for evaluation of the method did not yield a correct path through all three wrist joints. The delineated joint margins of the remaining 48 radiographs were used for JSW quantification. It was found that 90% of the joints had a JSW deviating less than 20% from the mean JSW of manual indications, with the mean JSW error less than 10%. Conclusion: The proposed method is able to automatically quantify the JSW of radiographic wrist joints reliably. The proposed method may aid clinical researchers to study the progression of wrist joint damage in RA studies. Objective: Wrist joint space narrowing is a main radiographic outcome of rheumatoid arthritis (RA). Yet, automatic radiographic wrist joint space width (JSW) quantification for RA patients has not been widely investigated. The aim of this paper is to present an automatic method to quantify the JSW of three wrist joints that are least affected by bone overlapping and are frequently involved in RA. These joints are located around the scaphoid bone, viz. the multangular-navicular, capitate-navicular-lunate, and radiocarpal joints. Methods: The joint space around the scaphoid bone is detected by using consecutive searches of separate path segments, where each segment location aids in constraining the subsequent one. For joint margin delineation, first the boundary not affected by X-ray projection is extracted, followed by a backtrace process to obtain the actual joint margin. The accuracy of the quantified JSW is evaluated by comparison with the manually obtained ground truth. Results: Two of the 50 radiographs used for evaluation of the method did not yield a correct path through all three wrist joints. The delineated joint margins of the remaining 48 radiographs were used for JSW quantification. It was found that 90% of the joints had a JSW deviating less than 20% from the mean JSW of manual indications, with the mean JSW error less than 10%. Conclusion: The proposed method is able to automatically quantify the JSW of radiographic wrist joints reliably. The proposed method may aid clinical researchers to study the progression of wrist joint damage in RA studies.

  1. Kinematic control of robot with degenerate wrist

    NASA Technical Reports Server (NTRS)

    Barker, L. K.; Moore, M. C.

    1984-01-01

    Kinematic resolved rate equations allow an operator with visual feedback to dynamically control a robot hand. When the robot wrist is degenerate, the computed joint angle rates exceed operational limits, and unwanted hand movements can result. The generalized matrix inverse solution can also produce unwanted responses. A method is introduced to control the robot hand in the region of the degenerate robot wrist. The method uses a coordinated movement of the first and third joints of the robot wrist to locate the second wrist joint axis for movement of the robot hand in the commanded direction. The method does not entail infinite joint angle rates.

  2. Effects of radiofrequency probe application on irrigation fluid temperature in the wrist joint.

    PubMed

    Sotereanos, Dean G; Darlis, Nickolaos A; Kokkalis, Zinon T; Zanaros, George; Altman, Gregory T; Miller, Mark Carl

    2009-12-01

    Radiofrequency (RF) probes used in wrist arthroscopy may raise joint fluid temperature, increasing the risk of capsular and ligamentous damage. The purposes of the current study were to measure joint fluid temperature during wrist arthroscopy with the use of RF probes, and to determine whether using an outlet portal will reduce the maximum temperature. We performed wrist arthroscopy on 8 cadaveric arms. Ablation and coagulation cycles using RF probe were performed at documented locations within the joint. This was done for 60-second intervals on both the radial and ulnar side of the wrist, to mimic clinical practice. We used 4 fiberoptic phosphorescent probes to measure temperature (radial, ulnar, inflow-tube, and outflow-tube probes) and measured joint fluid temperature with and without outflow. There was a significant difference between wrists with and without outflow when examining maximum ablation temperatures (p < .002). All specimens showed higher maximum and average ablation temperatures without outflow. Maximum joint temperatures, greater than 60 degrees C, were observed in only no-outflow conditions. In performing RF ablation during wrist arthroscopy, the use of an outlet portal reduces the joint fluid temperature. Without an outlet portal, maximum temperatures can exceed desirable levels when using ablation; such temperatures have the potential to damage adjacent tissues. It is useful to maintain adequate outflow when using the radiofrequency probes during wrist arthroscopy.

  3. The effect of ball impact location on racket and forearm joint angle changes for one-handed tennis backhand groundstrokes.

    PubMed

    King, Mark; Hau, Agnes; Blenkinsop, Glen

    2017-07-01

    Recreational tennis players tend to have higher incidence of tennis elbow, and this has been hypothesised to be related to one-handed backhand technique and off-centre ball impacts on the racket face. This study aimed to investigate for a range of participants the effect of off-longitudinal axis and off-lateral axis ball-racket impact locations on racket and forearm joint angle changes immediately following impact in one-handed tennis backhand groundstrokes. Three-dimensional racket and wrist angular kinematic data were recorded for 14 university tennis players each performing 30 "flat" one-handed backhand groundstrokes. Off-longitudinal axis ball-racket impact locations explained over 70% of the variation in racket rotation about the longitudinal axis and wrist flexion/extension angles during the 30 ms immediately following impact. Off-lateral axis ball-racket impact locations had a less clear cut influence on racket and forearm rotations. Specifically off-longitudinal impacts below the longitudinal axis forced the wrist into flexion for all participants with there being between 11° and 32° of forced wrist flexion for an off-longitudinal axis impact that was 1 ball diameter away from the midline. This study has confirmed that off-longitudinal impacts below the longitudinal axis contribute to forced wrist flexion and eccentric stretch of the wrist extensors and there can be large differences in the amount of forced wrist flexion from individual to individual and between strokes with different impact locations.

  4. 21 CFR 888.3790 - Wrist joint metal constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Wrist joint metal constrained cemented prosthesis. 888.3790 Section 888.3790 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3790 Wrist joint metal...

  5. 21 CFR 888.3790 - Wrist joint metal constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Wrist joint metal constrained cemented prosthesis. 888.3790 Section 888.3790 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3790 Wrist joint metal...

  6. 21 CFR 888.3790 - Wrist joint metal constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Wrist joint metal constrained cemented prosthesis. 888.3790 Section 888.3790 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3790 Wrist joint metal...

  7. Effect of traction on wrist joint space and cartilage visibility with and without MR arthrography

    PubMed Central

    Griffith, James F; Tang, W K; Ng, Alex W H; Yeung, David K W

    2017-01-01

    Objective: To compare the effect of traction during non-arthrographic and arthrographic MR examination of the wrist with regard to joint space width, joint fluid dispersion and cartilage surface visibility. Methods: Prospective 3-T MRI study of 100 wrists in 96 patients. The first 50 wrists underwent MR arthrography first without traction and then with traction. The following 50 wrists underwent standard MR first without traction and then with traction. On these examinations, two radiologists independently measured (i) joint space width, semi-quantitatively graded (ii) joint fluid dispersion between opposing cartilage surfaces and (iii) articular cartilage surface visibility. The three parameters were compared between the two groups. Results: Traction led to an increase in joint space width at nearly all joints in all patients (p < 0.05), although more so in the arthrography (∆ = 0.08–0.79 mm, all p < 0.05) than in the non-arthrography (∆ = 0.001–0.61 mm, all p < 0.05) group. Joint fluid dispersion and cartilage surface visibility improved after traction in nearly all joints (p < 0.05) in all patients and more so in the arthographic than in the non-arthrography group. Conclusion: Traction did significantly improve cartilage surface visibility for standard MRI of the wrist although the effect was not as great as that seen with MR arthography or MR arthrography with traction. Advances in knowledge: This is the first study to show the beneficial effect of traction during standard non-arthrography MRI of the wrist and compare the effect of traction between non-arthrographic and arthrographic MRI of the wrist. PMID:28181830

  8. 21 CFR 888.3760 - Wrist joint carpal scaphoid polymer prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint carpal scaphoid polymer prosthesis. 888.3760 Section 888.3760 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... scaphoid polymer prosthesis. (a) Identification. A wrist joint carpal scaphoid polymer prosthesis is a one...

  9. 21 CFR 888.3770 - Wrist joint carpal trapezium polymer prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint carpal trapezium polymer prosthesis. 888.3770 Section 888.3770 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... trapezium polymer prosthesis. (a) Identification. A wrist joint carpal trapezium polymer prosthesis is a one...

  10. 21 CFR 888.3750 - Wrist joint carpal lunate polymer prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint carpal lunate polymer prosthesis. 888.3750 Section 888.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... lunate polymer prosthesis. (a) Identification. A wrist joint carpal lunate prosthesis is a one-piece...

  11. 21 CFR 888.3750 - Wrist joint carpal lunate polymer prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Wrist joint carpal lunate polymer prosthesis. 888.3750 Section 888.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... lunate polymer prosthesis. (a) Identification. A wrist joint carpal lunate prosthesis is a one-piece...

  12. 21 CFR 888.3770 - Wrist joint carpal trapezium polymer prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Wrist joint carpal trapezium polymer prosthesis. 888.3770 Section 888.3770 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... trapezium polymer prosthesis. (a) Identification. A wrist joint carpal trapezium polymer prosthesis is a one...

  13. 21 CFR 888.3760 - Wrist joint carpal scaphoid polymer prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Wrist joint carpal scaphoid polymer prosthesis. 888.3760 Section 888.3760 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... scaphoid polymer prosthesis. (a) Identification. A wrist joint carpal scaphoid polymer prosthesis is a one...

  14. 21 CFR 888.3750 - Wrist joint carpal lunate polymer prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Wrist joint carpal lunate polymer prosthesis. 888.3750 Section 888.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... lunate polymer prosthesis. (a) Identification. A wrist joint carpal lunate prosthesis is a one-piece...

  15. 21 CFR 888.3770 - Wrist joint carpal trapezium polymer prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Wrist joint carpal trapezium polymer prosthesis. 888.3770 Section 888.3770 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... trapezium polymer prosthesis. (a) Identification. A wrist joint carpal trapezium polymer prosthesis is a one...

  16. 21 CFR 888.3760 - Wrist joint carpal scaphoid polymer prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Wrist joint carpal scaphoid polymer prosthesis. 888.3760 Section 888.3760 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... scaphoid polymer prosthesis. (a) Identification. A wrist joint carpal scaphoid polymer prosthesis is a one...

  17. 21 CFR 888.3770 - Wrist joint carpal trapezium polymer prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Wrist joint carpal trapezium polymer prosthesis. 888.3770 Section 888.3770 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... trapezium polymer prosthesis. (a) Identification. A wrist joint carpal trapezium polymer prosthesis is a one...

  18. 21 CFR 888.3750 - Wrist joint carpal lunate polymer prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Wrist joint carpal lunate polymer prosthesis. 888.3750 Section 888.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... lunate polymer prosthesis. (a) Identification. A wrist joint carpal lunate prosthesis is a one-piece...

  19. 21 CFR 888.3760 - Wrist joint carpal scaphoid polymer prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Wrist joint carpal scaphoid polymer prosthesis. 888.3760 Section 888.3760 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... scaphoid polymer prosthesis. (a) Identification. A wrist joint carpal scaphoid polymer prosthesis is a one...

  20. 21 CFR 888.3750 - Wrist joint carpal lunate polymer prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Wrist joint carpal lunate polymer prosthesis. 888.3750 Section 888.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... lunate polymer prosthesis. (a) Identification. A wrist joint carpal lunate prosthesis is a one-piece...

  1. 21 CFR 888.3760 - Wrist joint carpal scaphoid polymer prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Wrist joint carpal scaphoid polymer prosthesis. 888.3760 Section 888.3760 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... scaphoid polymer prosthesis. (a) Identification. A wrist joint carpal scaphoid polymer prosthesis is a one...

  2. 21 CFR 888.3770 - Wrist joint carpal trapezium polymer prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Wrist joint carpal trapezium polymer prosthesis. 888.3770 Section 888.3770 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... trapezium polymer prosthesis. (a) Identification. A wrist joint carpal trapezium polymer prosthesis is a one...

  3. Analysis of Hand and Wrist Postural Synergies in Tolerance Grasping of Various Objects

    PubMed Central

    Liu, Yuan; Jiang, Li; Yang, Dapeng; Liu, Hong

    2016-01-01

    Human can successfully grasp various objects in different acceptable relative positions between human hand and objects. This grasp functionality can be described as the grasp tolerance of human hand, which is a significant functionality of human grasp. To understand the motor control of human hand completely, an analysis of hand and wrist postural synergies in tolerance grasping of various objects is needed. Ten healthy right-handed subjects were asked to perform the tolerance grasping with right hand using 6 objects of different shapes, sizes and relative positions between human hand and objects. Subjects were wearing CyberGlove attaching motion tracker on right hand, allowing a measurement of the hand and wrist postures. Correlation analysis of joints and inter-joint/inter-finger modules were carried on to explore the coordination between joints or modules. As the correlation between hand and wrist module is not obvious in tolerance grasping, individual analysis of wrist synergies would be more practical. In this case, postural synergies of hand and wrist were then presented separately through principal component analysis (PCA), expressed through the principal component (PC) information transmitted ratio, PC elements distribution and reconstructed angle error of joints. Results on correlation comparison of different module movements can be well explained by the influence factors of the joint movement correlation. Moreover, correlation analysis of joints and modules showed the wrist module had the lowest correlation among all inter-finger and inter-joint modules. Hand and wrist postures were both sufficient to be described by a few principal components. In terms of the PC elements distribution of hand postures, compared with previous investigations, there was a greater proportion of movement in the thumb joints especially the interphalangeal (IP) and opposition rotation (ROT) joint. The research could serve to a complete understanding of hand grasp, and the design, control of the anthropomorphic hand and wrist. PMID:27580298

  4. Effects of Neoprene Wrist/Hand Splints on Handwriting for Students with Joint Hypermobility Syndrome: A Single System Design Study

    ERIC Educational Resources Information Center

    Frohlich, Lauren; Wesley, Alison; Wallen, Margaret; Bundy, Anita

    2012-01-01

    Purpose: Pain associated with hypermobility of wrist and hand joints can contribute to decreased handwriting output. This study examined the effectiveness of a neoprene wrist/hand splint in reducing pain and increasing handwriting speed and endurance for students with joint hypermobility syndrome. Methods: Multiple baseline, single system design…

  5. Wrist joint assembly

    NASA Technical Reports Server (NTRS)

    Kersten, L.; Johnson, J. D. (Inventor)

    1978-01-01

    A wrist joint assembly is provided for use with a mechanical manipulator arm for finely positioning an end-effector carried by the wrist joint on the terminal end of the manipulator arm. The wrist joint assembly is pivotable about a first axis to produce a yaw motion, a second axis is to produce a pitch motion, and a third axis to produce a roll motion. The wrist joint assembly includes a disk segment affixed to the terminal end of the manipulator arm and a first housing member, a second housing member, and a third housing member. The third housing member and the mechanical end-effector are moved in the yaw, pitch, and roll motion. Drive means are provided for rotating each of the housings about their respective axis which includes a cluster of miniature motors having spur gears carried on the output drive shaft which mesh with a center drive gear affixed on the housing to be rotated.

  6. Development of an Underactuated 2-DOF Wrist Joint using McKibben PAMs

    NASA Astrophysics Data System (ADS)

    Rajagopal, S. P.; Jain, S.; Ramasubramanian, S. N.; Johnson, B. V.; Dwivedy, S. K.

    2014-10-01

    In this work, model of an underactuated 2-DOF wrist joint with pneumatically actuated muscles is proposed. For the joint, McKibben-type artificial muscles are used in parallel configuration for the actuation. For each Degree of Freedom (DOF) one agonist-antagonist pair arrangement is usually used with a pulley mechanism. A mathematical model of wrist joint is derived using conventional forward kinematic analysis. The static model relating pressure in the muscle with the orientation of the wrist joint is obtained by combining the experimental data and mathematical model. Regulation of pressure can be achieved by pulse width modulation control of on/off solenoid valves. A set of free vibration experiments are done for the dynamic identification of the muscle characteristics.

  7. Dexterous Humanoid Robotic Wrist

    NASA Technical Reports Server (NTRS)

    Ihrke, Chris A. (Inventor); Bridgwater, Lyndon (Inventor); Reich, David M. (Inventor); Wampler, II, Charles W. (Inventor); Askew, Scott R. (Inventor); Diftler, Myron A. (Inventor); Nguyen, Vienny (Inventor)

    2013-01-01

    A humanoid robot includes a torso, a pair of arms, a neck, a head, a wrist joint assembly, and a control system. The arms and the neck movably extend from the torso. Each of the arms includes a lower arm and a hand that is rotatable relative to the lower arm. The wrist joint assembly is operatively defined between the lower arm and the hand. The wrist joint assembly includes a yaw axis and a pitch axis. The pitch axis is disposed in a spaced relationship to the yaw axis such that the axes are generally perpendicular. The pitch axis extends between the yaw axis and the lower arm. The hand is rotatable relative to the lower arm about each of the yaw axis and the pitch axis. The control system is configured for determining a yaw angle and a pitch angle of the wrist joint assembly.

  8. Hyperstaticity for ergonomie design of a wrist exoskeleton.

    PubMed

    Esmaeili, Mohammad; Jarrassé, Nathanaël; Dailey, Wayne; Burdet, Etienne; Campolo, Domenico

    2013-06-01

    Increasing the level of transparency in rehabilitation devices has been one of the main goals in robot-aided neurorehabilitation for the past two decades. This issue is particularly important to robotic structures that mimic the human counterpart's morphology and attach directly to the limb. Problems arise for complex joints such as the human wrist, which cannot be accurately matched with a traditional mechanical joint. In such cases, mechanical differences between human and robotic joint cause hyperstaticity (i.e. overconstraint) which, coupled with kinematic misalignments, leads to uncontrolled force/torque at the joint. This paper focuses on the prono-supination (PS) degree of freedom of the forearm. The overall force and torque in the wrist PS rotation is quantified by means of a wrist robot. A practical solution to avoid hyperstaticity and reduce the level of undesired force/torque in the wrist is presented, which is shown to reduce 75% of the force and 68% of the torque.

  9. The influence of hand positions on biomechanical injury risk factors at the wrist joint during the round-off skills in female gymnastics.

    PubMed

    Farana, Roman; Jandacka, Daniel; Uchytil, Jaroslav; Zahradnik, David; Irwin, Gareth

    2017-01-01

    The aim of this study was to examine the biomechanical injury risk factors at the wrist, including joint kinetics, kinematics and stiffness in the first and second contact limb for parallel and T-shape round-off (RO) techniques. Seven international-level female gymnasts performed 10 trials of the RO to back handspring with parallel and T-shape hand positions. Synchronised kinematic (3D motion analysis system; 247 Hz) and kinetic (two force plates; 1235 Hz) data were collected for each trial. A two-way repeated measure analysis of variance (ANOVA) assessed differences in the kinematic and kinetic parameters between the techniques for each contact limb. The main findings highlighted that in both the RO techniques, the second contact limb wrist joint is exposed to higher mechanical loads than the first contact limb demonstrated by increased axial compression force and loading rate. In the parallel technique, the second contact limb wrist joint is exposed to higher axial compression load. Differences between wrist joint kinetics highlight that the T-shape technique may potentially lead to reducing these bio-physical loads and consequently protect the second contact limb wrist joint from overload and biological failure. Highlighting the biomechanical risk factors facilitates the process of technique selection making more objective and safe.

  10. Simulated Radioscapholunate Fusion Alters Carpal Kinematics While Preserving Dart-Thrower's Motion

    PubMed Central

    Calfee, Ryan P.; Leventhal, Evan L.; Wilkerson, Jim; Moore, Douglas C.; Akelman, Edward; Crisco, Joseph J.

    2014-01-01

    Purpose Midcarpal degeneration is well documented after radioscapholunate fusion. This study tested the hypothesis that radioscapholunate fusion alters the kinematic behavior of the remaining lunotriquetral and midcarpal joints, with specific focus on the dart-thrower's motion. Methods Simulated radioscapholunate fusions were performed on 6 cadaveric wrists in an anatomically neutral posture. Two 0.060-in. carbon fiber pins were placed from proximal to distal across the radiolunate and radioscaphoid joints, respectively. The wrists were passively positioned in a custom jig toward a full range of motion along the orthogonal axes as well as oblique motions, with additional intermediate positions along the dart-thrower's path. Using a computed tomography– based markerless bone registration technique, each carpal bone's three-dimensional rotation was defined as a function of wrist flexion/extension from the pinned neutral position. Kinematic data was analyzed against data collected on the same wrist prior to fixation using hierarchical linear regression analysis and paired Student's t-tests. Results After simulated fusion, wrist motion was restricted to an average flexion-extension arc of 48°, reduced from 77°, and radial-ulnar deviation arc of 19°, reduced from 33°. The remaining motion was maximally preserved along the dart-thrower's path from radial-extension toward ulnar-flexion. The simulated fusion significantly increased rotation through the scaphotrapezial joint, scaphocapitate joint, triquetrohamate joint, and lunotriquetral joint. For example, in the pinned wrist, the rotation of the hamate relative to the triquetrum increased 85%. Therefore, during every 10° of total wrist motion, the hamate rotated an average of nearly 8° relative to the triquetrum after pinning versus 4° in the normal state. Conclusions Simulated radioscapholunate fusion altered midcarpal and lunotriquetral kinematics. The increased rotations across these remaining joints provide one potential explanation for midcarpal degeneration after radioscapholunate fusion. Additionally, this fusion model confirms the dart-thrower's hypothesis, as wrist motion after simulated radioscapholunate fusion was primarily preserved from radial-extension toward ulnar-flexion. PMID:18406953

  11. Evaluation of an Image-Based Tool to Examine the Effect of Fracture Alignment and Joint Congruency on Outcomes after Wrist Fracture.

    PubMed

    Lalone, Emily A; Grewal, Ruby; King, Graham W; MacDermid, Joy C

    2015-01-01

    Some mal-alignment of the wrist occurs in up to 71% of patients following a distal radius fracture. A multiple case study was used to provide proof of principle of an image-based technique to investigate the evolution and impact of post-traumatic joint changes at the distal radioulnar joint. Participants who had a unilateral distal radius fracture who previously participated in a prospective study were recruited from a single tertiary hand center. Long term follow-up measures of pain, disability, range of motion and radiographic alignment were obtained and compared to joint congruency measures. The inter-bone distance, a measure of joint congruency was quantified from reconstructed CT bone models of the distal radius and ulna and the clinical outcome was quantified using the patient rated wrist evaluation. In all four cases, acceptable post-reduction alignment and minimal pain/disability at 1-year suggested good clinical outcomes. However, 10 years following injury, 3 out of 4 patients had radiographic signs of degenerative changes occurring in their injured wrist (distal radioulnar joint/radio-carpal joint). Proximity maps displaying inter-bone distances showed asymmetrical congruency between wrists in these three patients. The 10-year PRWE (patient rated wrist evaluation) varied from 4 to 60, with 3 reporting minimal pain/disability and one experiencing high pain/disability. These illustrative cases demonstrate long-term joint damage post-fracture is common and occurs despite positive short-term clinical outcomes. Imaging and functional outcomes are not necessarily correlated. A novel congruency measure provides an indicator of the overall impact of joint mal-alignment that can be used to determine predictors of post-traumatic arthritis and is viable for clinical or large cohort studies.

  12. STS-111 Flight Day 09 Highlights

    NASA Technical Reports Server (NTRS)

    2002-01-01

    The STS-111 flight crew consists of Kenneth D. Cockrell, Commander, Paul S. Lockhart, Pilot, Franklin R. Chang-Diaz, Mission Specialist, Philippe Perrin, (CNES), Mission Specialist, Valery G. Korzun, (RSA), ISS Up, Peggy A. Whitson, ISS Up , Sergei Y. Treschev (RSC), ISS Up, Yuri I. Onufriyenko (RSA), ISS Down, Carl E. Walz, and Daniel W. Bursch (ISS) Down. The main goal on this ninth day of flight STS-111, is to replace the wrist roll joint of the Robotic Arm on the International Space Station. Live footage of the wrist roll joint replacement is presented. Paul Lockhart is the spacewalk coordinator for this mission. Franklin Chang-Diaz and Philippe Perrin, are responsible for replacing the wrist roll joint and performing maintenance activities. The spacewalk to repair this joint occurs outside the Space Station's Quest Airlock. The wrist roll joint was replaced successfully. The spacewalk took approximately 7 hours and 17 minutes to complete.

  13. Wrist Pain in Gymnasts: A Review of Common Overuse Wrist Pathology in the Gymnastics Athlete.

    PubMed

    Benjamin, Holly J; Engel, Sean C; Chudzik, Debra

    Injury rates among gymnasts are among the highest of any sport at the high school and collegiate level per athletic exposure. The wrist has increased injury risk due to repetitive physical stresses predisposing it to acute injury, overuse, and degenerative damage. This article will review the most common overuse wrist injuries seen in gymnasts. Prompt evaluation and management is necessary to avoid the negative sequelae that can often accompany these injuries. Little is known about effective sport-specific injury prevention strategies, but general guidelines for overuse injury prevention including limiting excessive loading of the wrist, maintaining wrist joint flexibility, an emphasis on proper technique, and incorporating wrist and general core strengthening seem beneficial. General return to play principles are similar for all gymnast-related wrist injuries, including resolution of pain, restoration of normal wrist joint function, completion of a progressive rehabilitation program, and use of proper technique.

  14. Conformational Changes in the Carpus During Finger Traps Distraction

    PubMed Central

    Leventhal, Evan L.; Moore, Douglas C.; Akelman, Edward; Wolfe, Scott W.; Crisco, Joseph J.

    2010-01-01

    Introduction Wrist distraction is a common treatment maneuver used clinically for the reduction of distal radial fractures and mid-carpal dislocations. Wrist distraction is also required during wrist arthroscopy to access the radiocarpal joint and has been used as a test for scapholunate ligament injury. However, the effect of a distraction load on the normal wrist has not been well studied. The purpose of this study was to measure the 3-D conformational changes of the carpal bones in the normal wrist as a result of a static distractive load. Methods The dominant wrists of 14 healthy volunteers were scanned using computed tomography at rest and during application of 98N of distraction. Load was applied using finger traps and volunteers were encouraged to relax their forearm muscles and to allow distraction of the wrist. The motions of the bones in the wrist were tracked between the unloaded and loaded trial using markerless bone registration. The average displacement vector of each bone was calculated relative to the radius as well as the interbone distances for 20 bone-bone interactions. Joint separation was estimated at the radiocarpal, midcarpal and carpal-metacarpal joints in the direction of loading using the radius, lunate, capitate and 3rd metacarpal. Results With loading, the distance between the radius and 3rd metacarpal increased an average of 3.3±3.1mm in the direction of loading. This separation was primarily located in the axial direction at the radiocarpal (1.0±1.0mm) and midcarpal (2.0±1.7mm) joints. There were minimal changes in the transverse direction within the distal row, although the proximal row narrowed by 0.98±0.7mm. Distraction between the radius and scaphoid (2.5±2.2mm) was 2.4 times greater than between the radius and lunate (1.0±1.0mm). Conclusions Carpal distraction has a significant effect on the conformation of the carpus, especially at the radiocarpal and midcarpal joints. In the normal wrist, external traction causes twice as much distraction at the lunocapitate joint than at the radiolunate joint. PMID:20141894

  15. Conformational changes in the carpus during finger trap distraction.

    PubMed

    Leventhal, Evan L; Moore, Douglas C; Akelman, Edward; Wolfe, Scott W; Crisco, Joseph J

    2010-02-01

    Wrist distraction is a common treatment maneuver used clinically for the reduction of distal radial fractures and midcarpal dislocations. Wrist distraction is also required during wrist arthroscopy to access the radiocarpal joint and has been used as a test for scapholunate ligament injury. However, the effect of a distraction load on the normal wrist has not been well studied. The purpose of this study was to measure the three-dimensional conformational changes of the carpal bones in the normal wrist as a result of a static distractive load. Using computed tomography, the dominant wrists of 14 healthy volunteers were scanned at rest and during application of 98 N of distraction. Load was applied using finger traps, and volunteers were encouraged to relax their forearm muscles and to allow distraction of the wrist. The motions of the bones in the wrist were tracked between the unloaded and loaded trial using markerless bone registration. The average displacement vector of each bone relative to the radius was calculated, as were the interbone distances for 20 bone-bone interactions. Joint separation was estimated at the radiocarpal, midcarpal, and carpometacarpal joints in the direction of loading using the radius, lunate, capitate, and third metacarpal. With loading, the distance between the radius and third metacarpal increased an average of 3.3 mm +/- 3.1 in the direction of loading. This separation was primarily in the axial direction at the radiocarpal (1.0 mm +/- 1.0) and midcarpal (2.0 mm +/- 1.7) joints. There were minimal changes in the transverse direction within the distal row, although the proximal row narrowed by 0.98 mm +/- 0.7. Distraction between the radius and scaphoid (2.5 mm +/- 2.2) was 2.4 times greater than that between the radius and lunate (1.0 mm +/- 1.0). Carpal distraction has a significant (p < .01) effect on the conformation of the carpus, especially at the radiocarpal and midcarpal joints. In the normal wrist, external traction causes twice as much distraction at the lunocapitate joint than at the radiolunate joint. Copyright 2010. Published by Elsevier Inc.

  16. Robot-Aided Mapping of Wrist Proprioceptive Acuity across a 3D Workspace

    PubMed Central

    Marini, Francesca; Squeri, Valentina; Morasso, Pietro; Konczak, Jürgen; Masia, Lorenzo

    2016-01-01

    Proprioceptive signals from peripheral mechanoreceptors form the basis for bodily perception and are known to be essential for motor control. However we still have an incomplete understanding of how proprioception differs between joints, whether it differs among the various degrees-of-freedom (DoFs) within a particular joint, and how such differences affect motor control and learning. We here introduce a robot-aided method to objectively measure proprioceptive function: specifically, we systematically mapped wrist proprioceptive acuity across the three DoFs of the wrist/hand complex with the aim to characterize the wrist position sense. Thirty healthy young adults performed an ipsilateral active joint position matching task with their dominant wrist using a haptic robotic exoskeleton. Our results indicate that the active wrist position sense acuity is anisotropic across the joint, with the abduction/adduction DoF having the highest acuity (the error of acuity for flexion/extension is 4.64 ± 0.24°; abduction/adduction: 3.68 ± 0.32°; supination/pronation: 5.15 ± 0.37°) and they also revealed that proprioceptive acuity decreases for smaller joint displacements. We believe this knowledge is imperative in a clinical scenario when assessing proprioceptive deficits and for understanding how such sensory deficits relate to observable motor impairments. PMID:27536882

  17. Quantitative detection of cartilage surfaces and ligament geometry of the wrist using an imaging cryomicrotome system.

    PubMed

    Dvinskikh, N A; Blankevoort, L; Foumani, M; Spaan, J A E; Streekstra, G J

    2010-03-22

    Biomechanical models may aid in improving diagnosis and treatment of wrist joint disorders. As input, geometrical information is required for model development. Previous studies acquired some elements of the average wrist joint geometry. However, there is a close geometric functional match between articulating surfaces and ligament geometry. Therefore, biomechanical models need to be fed with the geometric data of individual joints. This study is aimed at acquiring geometric data of cartilage surfaces and ligaments from individual wrist joints by using a cryomicrotome imaging system and the evaluation of inter- and intra-observer variability of the data. The 3D geometry of 30 cartilage surfaces and 15 ligaments in three cadaver wrists was manually detected and quantitatively reconstructed. The inter- and intra-observer variability of the cartilage surface detection was 0.14 and 0.19 mm, respectively. For the position of the radius attachment of the dorsal radiocarpal ligament (DRC), the observer variations were 0.12 and 0.65 mm, for intra-/inter-observer, respectively. For the DRC attachment on the triquetrum, the observer variations were 0.22 and 1.19 mm. Anatomic reconstruction from 3D cryomicrotome images offer a method to obtain unique geometry data of the entire wrist joint for modeling purposes. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  18. The compensatory motion of wrist immobilization on thumb and index finger performance--kinematic analysis and clinical implications.

    PubMed

    Liu, Chien-Hsiou; Chiang, Hsin-Yu; Chen, Kun-Hung

    2015-01-01

    Based on the high prevalence of people with problems in the wrist and hand simultaneously, it is of its importance to clarify whether hand joints exert extra motion to compensate for wrist motion while immobilized. This study aimed to measure the compensatory movement of the thumb and index finger when people perform daily activities with an immobilized wrist. Thirty healthy volunteers were recruited in this study. A wrist splint, the Jebsen-Taylor Hand Function Test, and the OptoTrak Certus motion tracking system were used. Seven inter-digit mean joint angles of the index finger and thumb were calculated. Paired sample t-test was used. (1) The compensatory motions were noted in the Metacarpophalangeal and Carpometacarpal joints of the thumb, and the proximal interphalangeal joints of the index finger; (2) The manifestation of compensatory motion was related to type of activity performed except when picking up light and heavy cans. The compensatory motions appeared while the wrist was immobilized and were found to be disadvantageous to the progression of disease. In the future, studies need to be done to understand how to select products with correct ergonomic design to enable people to reap greater benefits from wearing wrist splints.

  19. Biomechanical analyses of prolonged handwriting in subjects with and without perceived discomfort.

    PubMed

    Chang, Shao-Hsia; Chen, Chien-Liang; Yu, Nan-Ying

    2015-10-01

    Since wrist-joint position affects finger muscle length and grip strength, we studied its biomechanical relevance in prolonged handwriting. We recruited participants from young adults, aged 18-24, and separated them into control (n=22) and in-pain (n=18) groups, based whether or not they experience pain while handwriting. The participants then performed a writing task for 30 min on a computerized system which measured their wrist-joint angle and documented their handwriting kinematics. The in-pain group perceived more soreness and had a less-extended wrist joint, longer on-paper time, and slower stroke velocity compared to control group. There was no significant difference in handwriting speed and quality between the two groups. The wrist extension angle significantly correlated with perceived soreness. Ergonomic and biomechanical analyses provide important information about the handwriting process. Knowledge of pen tip movement kinematics and wrist-joint position can help occupational therapists plan treatment for individuals with handwriting induced pain. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. [Carpus and distal radioulnar joint : Clinical and radiological examination].

    PubMed

    Spies, C K; Langer, M F; Unglaub, F; Mühldorfer-Fodor, M; Müller, L P; Ahrens, C; Schlindwein, S F

    2016-08-01

    A precise medical history and specific symptom-oriented clinical tests of the wrist joint should always precede any radiological, computed tomography (CT) or magnetic resonance imaging (MRI) diagnostics. In many cases, specific clinical tests of the wrist joint allow at least a preliminary diagnosis, which can be supported by standard radiography using correct projections. A systematic approach is recommended covering the radiocarpal, midcarpal, ulnocarpal and distal radioulnar joints. Exact identification of the palpable anatomic landmarks is mandatory for correct application and interpretation of the various clinical tests. The results of the clinical tests in combination with radiological imaging can often detect precisely ruptures of distinct wrist joint ligaments and localized arthritis.

  1. Modular multimorphic kinematic arm structure and pitch and yaw joint for same

    DOEpatents

    Martin, H. Lee; Williams, Daniel M.; Holt, W. Eugene

    1989-01-01

    A multimorphic kinematic manipulator arm is provided with seven degrees of freedom and modular kinematic redundancy through identical pitch/yaw, shoulder, elbow and wrist joints and a wrist roll device at the wrist joint, which further provides to the manipulator arm an obstacle avoidance capability. The modular pitch/yaw joints are traction drive devices which provide backlash free operation with smooth torque transmission and enhanced rigidity. A dual input drive arrangement is provided for each joint resulting in a reduction of the load required to be assumed by each drive and providing selective pitch and yaw motions by control of the relative rotational directions of the input drive.

  2. Modular multimorphic kinematic arm structure and pitch and yaw joint for same

    DOEpatents

    Martin, H.L.; Williams, D.M.; Holt, W.E.

    1987-04-21

    A multimorphic kinematic manipulator arm is provided with seven degrees of freedom and modular kinematic redundancy through identical pitch/yaw, shoulder, elbow and wrist joints and a wrist roll device at the wrist joint, which further provides to the manipulator arm an obstacle avoidance capability. The modular pitch/yaw joints are traction drive devices which provide backlash free operation with smooth torque transmission and enhanced rigidity. A dual input drive arrangement is provided for each joint resulting in a reduction of the load required to be assumed by each drive means and providing selective pitch and yaw motions by control of the relative rotational directions of the input drive means. 12 figs.

  3. Relative Contributions of the Midcarpal and Radiocarpal Joints to Dart-Thrower's Motion at the Wrist.

    PubMed

    Kane, Patrick M; Vopat, Bryan G; Mansuripur, P Kaveh; Gaspar, Michael P; Wolfe, Scott W; Crisco, Joseph J; Got, Christopher

    2018-03-01

    To identify the relative contributions of the radiocarpal (RC) and midcarpal (MC) joints to dart-thrower's motion (DTM) of the wrist. Six cadaveric upper extremities were fixed to a custom-designed loading jig allowing for pure moment-rotation analysis in 24 different directions of wrist motion. Each specimen was tested in 3 states: intact, simulated radiocarpal fusion (sRCF) and simulated pancarpal fusion (sPCF). Moments of ± 1.5 Nm were applied at each of 24 directions for each state and the resulting wrist rotation recorded. Data from each specimen were reduced to compute the range of motion (ROM) envelopes and the orientation of the ROM for the 3 different states. The ROM was significantly decreased in the sRCF and sPCF groups compared with the intact group in the directions of the pure extension, radial extension, ulnar flexion, and ulnar deviation. No significant difference in ROM was detected between the sRCF and sPCF groups in any direction. The ROM envelopes for the intact, sRCF, and sPCF groups were all oriented obliquely to the axis of pure wrist flexion-extension near a path of ulnar flexion-radial extension, consistent with prior reports on DTM. Although both simulated fusion types decreased ROM compared with the intact wrist, the principal direction of wrist motion along the path of DTM was not significantly altered by simulated RCF or PCF. These findings suggest that the RC and MC joints can each contribute to a similar mechanical axis of motion located along the path of DTM when the other joint has been eliminated via fusion. Surgical options such as partial wrist fusions may maintain the native wrist's mechanical axis if either the RC or the MC joint is preserved, despite significant reduction in overall ROM. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  4. Ultrasound-Guided Steroid Injection of the Pisotriquetral Joint: A Multidisciplinary Effort.

    PubMed

    Brose, Steven W; Montfort, Janel; Gustafson, Kenneth J; Mittebrun, Ionica; Gauriloff, Samantha; Mosher, Mary; Bourbeau, Dennis J

    2017-12-01

    From the perspective of a multidisciplinary team, the authors describe the first reported use of ultrasound guidance for steroid injection into the pisotriquetral joint to relieve wrist pain of a person with spinal cord injury undergoing acute inpatient rehabilitation. Musculoskeletal ultrasound guidance was used to improve the accuracy of a corticosteroid injection of the pisotriquetral joint and the basal thumb in a 70-year-old man with paraplegia experiencing multifocal degenerative wrist pain. There was no bleeding or bruising after the injections, and the patient reported complete pain resolution 1 wk after the injections, which continued for over 1 yr. A multidisciplinary team was key in diagnosis, selection of treatment, and evaluation of treatment effect. Corticosteroid injection of the pisotriquetral joint under ultrasound guidance can be used as a treatment modality for managing wrist pain stemming from that joint. Further investigation and studies evaluating the use of ultrasound versus other imaging modalities for injection of the wrist are indicated.

  5. Application of the Blobo bluetooth ball in wrist rehabilitation training

    PubMed Central

    Hsieh, Wei-Min; Hwang, Yuh-Shyan; Chen, Shih-Ching; Tan, Sun-Yen; Chen, Chih-Chen; Chen, Yu-Luen

    2016-01-01

    [Purpose] The introduction of emerging technologies such as the wireless Blobo bluetooth ball with multimedia features can enhance wrist physical therapy training, making it more fun and enhancing its effects. [Methods] Wrist injuries caused by fatigue at work, improper exercise, and other conditions are very common. Therefore, the reconstruction of wrist joint function is an important issue. The efficacy of a newly developed integrated wrist joint rehabilitation game using a Blobo bluetooth ball with C# software installed was tested in wrist rehabilitation (Flexion, Extension, Ulnar Deviation, Radial Deviation). [Results] Eight subjects with normal wrist function participated in a test of the system’s stability and repeatability. After performing the Blobo bluetooth ball wrist physical therapy training, eight patients with wrist dysfunction experienced approximately 10° improvements in range of motion (ROM) of flexion extension, and ulnar deviation and about 6° ROM improvement in radial deviation. The subjects showed progress in important indicators of wrist function. [Conclusion] This study used the Blobo bluetooth ball in wrist physical therapy training and the preliminary results were encouraging. In the future, more diverse wrist or limb rehabilitation games should be developed to meet the needs of physical therapy training. PMID:26957723

  6. Application of the Blobo bluetooth ball in wrist rehabilitation training.

    PubMed

    Hsieh, Wei-Min; Hwang, Yuh-Shyan; Chen, Shih-Ching; Tan, Sun-Yen; Chen, Chih-Chen; Chen, Yu-Luen

    2016-01-01

    [Purpose] The introduction of emerging technologies such as the wireless Blobo bluetooth ball with multimedia features can enhance wrist physical therapy training, making it more fun and enhancing its effects. [Methods] Wrist injuries caused by fatigue at work, improper exercise, and other conditions are very common. Therefore, the reconstruction of wrist joint function is an important issue. The efficacy of a newly developed integrated wrist joint rehabilitation game using a Blobo bluetooth ball with C# software installed was tested in wrist rehabilitation (Flexion, Extension, Ulnar Deviation, Radial Deviation). [Results] Eight subjects with normal wrist function participated in a test of the system's stability and repeatability. After performing the Blobo bluetooth ball wrist physical therapy training, eight patients with wrist dysfunction experienced approximately 10° improvements in range of motion (ROM) of flexion extension, and ulnar deviation and about 6° ROM improvement in radial deviation. The subjects showed progress in important indicators of wrist function. [Conclusion] This study used the Blobo bluetooth ball in wrist physical therapy training and the preliminary results were encouraging. In the future, more diverse wrist or limb rehabilitation games should be developed to meet the needs of physical therapy training.

  7. Estimation of Finger Joint Angles Based on Electromechanical Sensing of Wrist Shape.

    PubMed

    Kawaguchi, Junki; Yoshimoto, Shunsuke; Kuroda, Yoshihiro; Oshiro, Osamu

    2017-09-01

    An approach to finger motion capture that places fewer restrictions on the usage environment and actions of the user is an important research topic in biomechanics and human-computer interaction. We proposed a system that electrically detects finger motion from the associated deformation of the wrist and estimates the finger joint angles using multiple regression models. A wrist-mounted sensing device with 16 electrodes detects deformation of the wrist from changes in electrical contact resistance at the skin. In this study, we experimentally investigated the accuracy of finger joint angle estimation, the adequacy of two multiple regression models, and the resolution of the estimation of total finger joint angles. In experiments, both the finger joint angles and the system output voltage were recorded as subjects performed flexion/extension of the fingers. These data were used for calibration using the least-squares method. The system was found to be capable of estimating the total finger joint angle with a root-mean-square error of 29-34 degrees. A multiple regression model with a second-order polynomial basis function was shown to be suitable for the estimation of all total finger joint angles, but not those of the thumb.

  8. Innervation of the wrist joint and surgical perspectives of denervation.

    PubMed

    Van de Pol, Gerrit J; Koudstaal, Maarten J; Schuurman, Arnold H; Bleys, Ronald L A W

    2006-01-01

    Because our experience with the techniques used in denervation surgery of the wrist joint often has proven insufficient in treating chronic pain we conducted an anatomic study to clarify the exact contributions of the nerves supplying the wrist joint. Our goal was to reveal all periosteal and capsular nerve connections and if necessary adjust our technique used in denervation surgery. Innervation of the wrist joint was investigated by microdissection and histologic examination of 18 human wrists. An acetylcholinesterase method was used to identify the nerves, both in whole-mount preparations and in sections. We found that the main innervation to the wrist capsule and periosteal nerve network came from the anterior interosseous nerve, lateral antebrachial cutaneous nerve, and posterior interosseous nerve. The palmar cutaneous branch of the median nerve, the deep branch of the ulnar nerve, the superficial branch of the radial nerve, and the dorsal branch of the ulnar nerve also were found to have connections with the capsule. The periosteal nerve branches did not appear to play a major role in the innervation of the capsule and ligaments; here the specific articular nerve branches proved more important. The posterior and medial antebrachial cutaneous nerves did not connect to the wrist capsule or periosteum but rather terminated in the extensor and flexor retinaculum. Based on our findings we propose to denervate the wrist by making 2 incisions. With one palmar and one dorsal incision it should be possible to disconnect the periosteum from the capsule and interrupt the majority of the capsular nerve branches.

  9. Associations of work activities requiring pinch or hand grip or exposure to hand-arm vibration with finger and wrist osteoarthritis: a meta-analysis.

    PubMed

    Hammer, Paula E C; Shiri, Rahman; Kryger, Ann I; Kirkeskov, Lilli; Bonde, Jens Peter

    2014-03-01

    We systematically reviewed the epidemiologic evidence linking finger and wrist osteoarthritis (OA) with work activities requiring pinch or hand grip or exposure to hand-arm vibration (HAV). PubMed and Embase databases were searched up to June 2013. We selected studies assessing the associations of radiographic diagnosed finger and/or wrist joint OA with work activities involving pinch or hand grip or exposure to HAV. We used specific criteria to evaluate completeness of reporting, potential confounding, and bias. Pooled odds ratios (OR) were computed using random-effects meta-analyses. Of the 19 studies included, 17 were cross-sectional, 1 was a prospective cohort, and 1 a case-control study. The meta-analyses of studies that controlled their estimates for at least age and gender showed the associations of pinch grip work with proximal interphalangeal joint [OR 1.56, 95% confidence interval (95% CI) 1.09-2.23] and the first carpometacarpal joint OA (OR 2.10, 95% CI 1.06-4.17), but not with distal interphalangeal, metacarpalphalangeal, or wrist joints OA. Hand grip work and exposure to HAV were not associated with any finger or wrist OA. Epidemiological studies provide limited evidence that pinch grip may increase the risk of wrist or finger OA, but causal relation cannot be resolved because of cross-sectional designs and inadequate characterization of biomechanical strain to the hand and wrist.

  10. 3D motion analysis of the wrist splint effect to wrist joint movement.

    PubMed

    Shin, Joong-Il; Park, Soo-Hee

    2017-06-01

    [Purpose] This study aimed to investigate the degree of straightness of the wrist joint, depending on the use of a wrist splint while opening a bottle cap. Its results may provide data for later studies on preventing accidents at workplaces and improving efficiency. [Subjects and Methods] Thirty Male and Female in their twenties who did not have hand-related diseases, fractures, or history that included neurological impairments associated with the hand were selected as subjects of the study. Wrist splints were made to fit the hand and lower arm of each subject. Evaluation assignments were carried out without and with the splints after 10 minutes of rest. To analyze the wrist movement in opening the bottle cap, a three-dimensional movement analyzing system by Zebris was used. [Results] Wrist angle decreased while opening caps of four different diameters while wearing splints, but not when splints were not worn. This means that wearing a splint may aid weakened wrist muscles. [Conclusion] Future studies should be conducted among subjects with damaged wrist muscles and evaluate the subjects in actual workplaces to obtain more objective and more valid data.

  11. Estimating anatomical wrist joint motion with a robotic exoskeleton.

    PubMed

    Rose, Chad G; Kann, Claudia K; Deshpande, Ashish D; O'Malley, Marcia K

    2017-07-01

    Robotic exoskeletons can provide the high intensity, long duration targeted therapeutic interventions required for regaining motor function lost as a result of neurological injury. Quantitative measurements by exoskeletons have been proposed as measures of rehabilitative outcomes. Exoskeletons, in contrast to end effector designs, have the potential to provide a direct mapping between human and robot joints. This mapping rests on the assumption that anatomical axes and robot axes are aligned well, and that movement within the exoskeleton is negligible. These assumptions hold well for simple one degree-of-freedom joints, but may not be valid for multi-articular joints with unique musculoskeletal properties such as the wrist. This paper presents an experiment comparing robot joint kinematic measurements from an exoskeleton to anatomical joint angles measured with a motion capture system. Joint-space position measurements and task-space smoothness metrics were compared between the two measurement modalities. The experimental results quantify the error between joint-level position measurements, and show that exoskeleton kinematic measurements preserve smoothness characteristics found in anatomical measures of wrist movements.

  12. Wrist kinetics after luno-triquetral dissociation: the changes in moment arms of the flexor carpi ulnaris tendon.

    PubMed

    Tang, Jin Bo; Xie, Ren Gou; Yu, Xiao Wei; Chen, Feng

    2002-11-01

    Wrist biomechanics after luno-triquetral (LT) dissociation is important for understanding the clinical sequelae of the disease and for determining its treatment options. The LT interosseous ligament plays an important role in stabilizing the joint and damage to the ligament would be expected to significantly increase moment arms of tendon of the flexor carpi ulnaris (FCU), the principal ulnar wrist flexor. We investigated the changes in moment arms of FCU tendon after various amounts of sectioning of the ligaments proven to be associated with LT dissociation. In six fresh frozen cadaveric upper extremities, excursions of the FCU tendon were recorded simultaneously with wrist joint angulation during wrist flexion-extension and radioulnar deviation. Tendon excursions were measured in intact wrists, in wrists with sectioning of the dorsal portion of the LT interosseous ligament, in wrists with sectioning of the entire LT interosseous ligament, and finally in wrists with further sectioning of the dorsal radiotriquetral and intercarpal ligaments. Moment arms of the tendon were calculated from tendon excursions and joint motion angulations and expressed as percentage changes from those in the intact wrist. During wrist flexion-extension, moment arms of the FCU tendon after sectioning of the entire LT interosseous ligament and after sectioning of the two capsular ligaments were 112 +/- 7% and 114 +/- 8%, respectively; these values were significantly greater than those in the intact wrist. During radioulnar deviation, the moment arms were 114 +/- 11% after sectioning of the dorsal portion of the LT interosseous ligament, 134 +/- 15% after sectioning of the entire ligament, and 153 +/- 18% after sectioning of the capsular ligaments, again being significantly greater than the normal wrist. Increase in moment arms of the FCU tendon after loss of integrity of the LT interosseous ligament and dorsal capsular ligaments may contribute to clinical sequelae of LT dissociation and difficulty in treating this disorder.

  13. A structurally decoupled mechanism for measuring wrist torque in three degrees of freedom

    NASA Astrophysics Data System (ADS)

    Pan, Lizhi; Yang, Zhen; Zhang, Dingguo

    2015-10-01

    The wrist joint is a critical part of the human body for movement. Measuring the torque of the wrist with three degrees of freedom (DOFs) is important in some fields, including rehabilitation, biomechanics, ergonomics, and human-machine interfacing. However, the particular structure of the wrist joint makes it difficult to measure the torque in all three directions simultaneously. This work develops a structurally decoupled instrument for measuring and improving the measurement accuracy of 3-DOF wrist torque during isometric contraction. Three single-axis torque sensors were embedded in a customized mechanical structure. The dimensions and components of the instrument were designed based on requirement of manufacturability. A prototype of the instrument was machined, assembled, integrated, and tested. The results show that the structurally decoupled mechanism is feasible for acquiring wrist torque data in three directions either independently or simultaneously. As a case study, we use the device to measure wrist torques concurrently with electromyography signal acquisition in preparation for simultaneous and proportional myoelectric control of prostheses.

  14. A structurally decoupled mechanism for measuring wrist torque in three degrees of freedom.

    PubMed

    Pan, Lizhi; Yang, Zhen; Zhang, Dingguo

    2015-10-01

    The wrist joint is a critical part of the human body for movement. Measuring the torque of the wrist with three degrees of freedom (DOFs) is important in some fields, including rehabilitation, biomechanics, ergonomics, and human-machine interfacing. However, the particular structure of the wrist joint makes it difficult to measure the torque in all three directions simultaneously. This work develops a structurally decoupled instrument for measuring and improving the measurement accuracy of 3-DOF wrist torque during isometric contraction. Three single-axis torque sensors were embedded in a customized mechanical structure. The dimensions and components of the instrument were designed based on requirement of manufacturability. A prototype of the instrument was machined, assembled, integrated, and tested. The results show that the structurally decoupled mechanism is feasible for acquiring wrist torque data in three directions either independently or simultaneously. As a case study, we use the device to measure wrist torques concurrently with electromyography signal acquisition in preparation for simultaneous and proportional myoelectric control of prostheses.

  15. [Cinematography, a new diagnostic procedure in evaluation of the injured painful wrist joint].

    PubMed

    Werber, K D; Wuttge-Hannig, A; Hannig, C

    1990-01-01

    By the X-ray Cineradiografie we are able to examine and to judge the dynamic of the wrist bones by 50 pictures/sec. in comparison to one another and also depending on their ligaments. We did an investigation of 170 patients with painful wrist. With the method we were able to make up a clear diagnosis and to propose the therapy. I.e.: If consecutive shortening of the radius after distal radius fracture resulting ingruency of the wrist joint is relevant, or a scaphoid pseudarthrosis is fixed elastically, or a scaphoic dissociation is effective. The variations were shown in comparison to normal circumstances.

  16. A Modular Soft Robotic Wrist for Underwater Manipulation.

    PubMed

    Kurumaya, Shunichi; Phillips, Brennan T; Becker, Kaitlyn P; Rosen, Michelle H; Gruber, David F; Galloway, Kevin C; Suzumori, Koichi; Wood, Robert J

    2018-04-19

    This article presents the development of modular soft robotic wrist joint mechanisms for delicate and precise manipulation in the harsh deep-sea environment. The wrist consists of a rotary module and bending module, which can be combined with other actuators as part of a complete manipulator system. These mechanisms are part of a suite of soft robotic actuators being developed for deep-sea manipulation via submersibles and remotely operated vehicles, and are designed to be powered hydraulically with seawater. The wrist joint mechanisms can also be activated with pneumatic pressure for terrestrial-based applications, such as automated assembly and robotic locomotion. Here we report the development and characterization of a suite of rotary and bending modules by varying fiber number and silicone hardness. Performance of the complete soft robotic wrist is demonstrated in normal atmospheric conditions using both pneumatic and hydraulic pressures for actuation and under high ambient hydrostatic pressures equivalent to those found at least 2300 m deep in the ocean. This rugged modular wrist holds the potential to be utilized at full ocean depths (>10,000 m) and is a step forward in the development of jointed underwater soft robotic arms.

  17. The role of imaging in diagnosing diseases of the distal radioulnar joint, triangular fibrocartilage complex, and distal ulna.

    PubMed

    Squires, Judy H; England, Eric; Mehta, Kaushal; Wissman, Robert D

    2014-07-01

    The purpose of this article is to review the anatomy, biomechanics, and multimodality imaging findings of common and uncommon distal radioulnar joint (DRUJ), triangular fibrocartilage complex, and distal ulna abnormalities. The DRUJ is a common site for acute and chronic injuries and is frequently imaged to evaluate chronic wrist pain, forearm dysfunction, and traumatic forearm injury. Given the complex anatomy of the wrist, the radiologist plays a vital role in the diagnosis of wrist pain and dysfunction.

  18. 3D motion analysis of the wrist splint effect to wrist joint movement

    PubMed Central

    Shin, Joong-il; Park, Soo-hee

    2017-01-01

    [Purpose] This study aimed to investigate the degree of straightness of the wrist joint, depending on the use of a wrist splint while opening a bottle cap. Its results may provide data for later studies on preventing accidents at workplaces and improving efficiency. [Subjects and Methods] Thirty Male and Female in their twenties who did not have hand-related diseases, fractures, or history that included neurological impairments associated with the hand were selected as subjects of the study. Wrist splints were made to fit the hand and lower arm of each subject. Evaluation assignments were carried out without and with the splints after 10 minutes of rest. To analyze the wrist movement in opening the bottle cap, a three-dimensional movement analyzing system by Zebris was used. [Results] Wrist angle decreased while opening caps of four different diameters while wearing splints, but not when splints were not worn. This means that wearing a splint may aid weakened wrist muscles. [Conclusion] Future studies should be conducted among subjects with damaged wrist muscles and evaluate the subjects in actual workplaces to obtain more objective and more valid data. PMID:28626332

  19. Indium-111 leukocyte imaging in patients with rheumatoid arthritis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Uno, K.; Matsui, N.; Nohira, K.

    1986-03-01

    This study evaluates the usefulness of labeled leukocyte imaging in patients with rheumatoid arthritis. In 33 patients, the incidence of pain and swelling in 66 wrist joints and 66 knee joints was compared with the accumulation of (/sup 111/In)leukocytes. No accumulation of (/sup 111/In)leukocytes was seen in any of the patients' wrists (0/12) or knee joints (0/14) when both pain and swelling were absent. In contrast, 93% (25/27) of wrist joints and 80% (24/30) of knee joints with both pain and swelling were positive by (/sup 111/In)leukocyte scintigraphy. There was little correlation between the stage of the disease, as determinedmore » by radiography, and (/sup 111/In)leukocyte accumulation. This study suggests that (/sup 111/In)leukocyte imaging may be a reliable procedure for monitoring the activity of rheumatoid arthritis, especially for confirming the lack of an ongoing inflammatory response.« less

  20. Effects of neoprene wrist/hand splints on handwriting for students with joint hypermobility syndrome: a single system design study.

    PubMed

    Frohlich, Lauren; Wesley, Alison; Wallen, Margaret; Bundy, Anita

    2012-08-01

    Pain associated with hypermobility of wrist and hand joints can contribute to decreased handwriting output. This study examined the effectiveness of a neoprene wrist/hand splint in reducing pain and increasing handwriting speed and endurance for students with joint hypermobility syndrome. Multiple baseline, single system design (SSD) methodology was used. Four ninth grade students with handwriting difficulties because of joint hypermobility syndrome participated in this study. Visual and statistical (two standard deviation band method) analyses indicated a significant decrease in handwriting speed when using the splint for three out of four participants. No significant change in pain or endurance was noted during intervention. There was a significant decrease in pain following withdrawal of the splint for three participants. Evidence from this study does not support use of this particular splint for decreasing pain and increasing handwriting speed and endurance for ninth grade students with joint hypermobility syndrome.

  1. Kinematic synthesis of bevel-gear-type robotic wrist mechanisms

    NASA Astrophysics Data System (ADS)

    Lin, Chen-Chou

    Bevel-gear-type robotic wrist mechanisms are commonly used in industry. The reasons for their popularity are that they are compact, light-weight, and relatively inexpensive. However, there are singularities in their workspace, which substantially degrade their manipulative performance. The objective of this research is to develop an atlas of three-degree-of-freedom bevel-gear-type wrist mechanisms, and through dimensional synthesis to improve their kinematic performance. The dissertation contains two major parts: the first is structural analysis and synthesis, the other is kinematic analysis and dimensional synthesis. To synthesize the kinematic structures of bevel-gear-type wrist mechanisms, the kinematic structures are separated from their functional considerations. All kinematic structures which satisfy the mobility condition are enumerated in an unbiased, systematic manner. Then the bevel-gear-type wrist mechanisms are identified by applying the functional requirements. Structural analysis shows that a three-degree-of-freedom wrist mechanism usually consists of non-fractionated, two degree-of-freedom epicyclic gear train jointed with the base link. Therefore, the structural synthesis can be simplified into a problem of examining the atlas of non-fractionated, two-degree-of-freedom epicyclic gear trains. The resulting bevel-gear-type wrist mechanism has been categorized and evaluated. It is shown that three-degree-of-freedom, four-jointed wrist mechanisms are promising for further improving the kinematic performance. It is found that a spherical planetary gear train is necessarily imbedded in a three-degree-of-freedom, four-jointed wrist mechanism. Therefore, to study the workspace and singularity problems of three-degree-of-freedom four-jointed spherical wrist mechanisms, we have to study the trajectories of spherical planetary gear trains. The parametric equations of the trajectories and some useful geometric properties for the analysis and synthesis of workplace are derived. The workspace boundary equations can be derived via both geometric consideration and Jacobian analysis. The workspace is divided by inner and outer boundaries into regions of accessibility of zero, two, and four. The design criteria of full workspace and a maximum four-root region are established.

  2. Wrist Traction During MR Arthrography Improves Detection of Triangular Fibrocartilage Complex and Intrinsic Ligament Tears and Visibility of Articular Cartilage.

    PubMed

    Lee, Ryan K L; Griffith, James F; Ng, Alex W H; Nung, Ryan C H; Yeung, David K W

    2016-01-01

    The purpose of this study was to assess the effects of traction during MR arthrography of the wrist on joint space widening, cartilage visibility, and detection of tears of the triangular fibrocartilage complex (TFCC) and intrinsic ligaments. A prospective study included 40 wrists in 39 patients (25 men, 14 women; mean age, 35 years). MR arthrography was performed with a 3-T MRI system with and without axial traction. Two radiologists independently measured wrist and carpal joint space widths and semiquantitatively graded articular cartilage visibility. Using conventional arthrography as the reference standard and working in consensus, they assessed for the presence of tears of the TFCC, lunotriquetral ligament (LTL), and scapholunate ligament (SLL). Visibility of a tear before traction was compared with visibility after traction. With traction, all joint spaces in the wrist and carpus were significantly widened (change, 0.15-1.01 mm; all p < 0.006). Subjective cartilage visibility of all joint spaces improved after traction (all p ≤ 0.048) except for that of the radioscaphoid space, which was well visualized even before traction. Conventional arthrography depicted 24 TFCC tears, seven LTL tears, and three SLL tears. The accuracy of tear detection improved after traction for the TFCC (98% after traction vs 83% before traction), the LTL (100% vs 88%), and the SLL (100% vs 95%). Tear visibility improved after traction for 54% of TFCC tears, 71% of LTL tears, and 66% of SLL tears. Wrist MR arthrography with axial traction significantly improved the visibility of articular cartilage and the detection and visibility of tears of the TFCC and intrinsic ligaments. The results favor more widespread use of traction during MR arthrography of the wrist.

  3. The use of joint mobilization to improve clinical outcomes in hand therapy: a systematic review of the literature.

    PubMed

    Heiser, Rick; O'Brien, Virginia H; Schwartz, Deborah A

    2013-01-01

    Systematic review. Joint mobilizations are used as an intervention for improving range of motion, decreasing pain and ultimately improving function in patients with a wide variety of upper extremity diagnoses. However, there are only a limited number of studies describing this treatment for conditions affecting the elbow, wrist, and hand. Furthermore, it is unclear as to the most effective joint mobilization technique utilized and the most beneficial functional outcomes gained. Examine the current evidence describing joint mobilizations for treatment of conditions of the elbow, wrist and hand, and offer informative practical clinical guidance. Twenty-two studies dated between 1980 and 2011 were included in the systematic review for analysis. The current evidence provides moderate support for the inclusion of joint mobilizations in the treatment of lateral epicondylalgia (LE). In particular, mobilization with movement as described by Mulligan is supported with evidence from nine randomized clinical trials as an effective technique for the treatment of pain. Other described techniques include those known as Kaltenborn, Cyriax physical therapy, and Maitland, but the evidence for these techniques is limited. There is also limited evidence for the joint mobilizations in the treatment of wrist and hand conditions. The current literature offers limited support for joint mobilizations of the wrist and hand, and moderate support for joint mobilizations of the elbow for LE. There is moderate support for mobilization with movement. . Copyright © 2013 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  4. Frequency of radiographic damage and progression in individual joints in children with juvenile idiopathic arthritis.

    PubMed

    Giancane, Gabriella; Pederzoli, Silvia; Norambuena, Ximena; Ioseliani, Maka; Sato, Juliana; Gallo, Maria Chiara; Negro, Giorgia; Pistorio, Angela; Ruperto, Nicolino; Martini, Alberto; Ravelli, Angelo

    2014-01-01

    To evaluate the presence and progression of radiographic joint damage, as assessed with the adapted Sharp/van der Heijde score (SHS), in individual joints in the hand and wrist in patients with juvenile idiopathic arthritis (JIA) and to compare progression of damage among different JIA categories. A total of 372 radiographs of both wrists and hands obtained at first observation and at last followup visit (after 1-10 years) in 186 children with polyarticular-course JIA were evaluated. All radiographs were scored using the adapted SHS by 2 independent readers. Radiographic assessment included evaluation of joint space narrowing (JSN) and erosions on baseline and last followup radiographs and of progression of radiographic changes from baseline to last followup radiographs. Both JSN and erosions occurred in all adapted SHS areas. Overall, radiographic damage and progression were more common in the wrist and less common in metacarpophalangeal (MCP) joints. The hamate and capitate areas appeared particularly vulnerable to cartilage loss. Erosions were identified most frequently in the hamate and capitate bones as well as in the second and third metacarpal bases. Patients with extended oligoarthritis were distinctly less susceptible to JSN in hand joints, whereas patients with polyarthritis showed a greater tendency to developing erosions in hand joints. Radiographic joint damage and progression in our patients with JIA were seen most commonly in the wrist and less commonly in MCP joints. The frequency and localization of structural abnormalities differed markedly across disease categories. Copyright © 2014 by the American College of Rheumatology.

  5. Compensating for intersegmental dynamics across the shoulder, elbow, and wrist joints during feedforward and feedback control.

    PubMed

    Maeda, Rodrigo S; Cluff, Tyler; Gribble, Paul L; Pruszynski, J Andrew

    2017-10-01

    Moving the arm is complicated by mechanical interactions that arise between limb segments. Such intersegmental dynamics cause torques applied at one joint to produce movement at multiple joints, and in turn, the only way to create single joint movement is by applying torques at multiple joints. We investigated whether the nervous system accounts for intersegmental limb dynamics across the shoulder, elbow, and wrist joints during self-initiated planar reaching and when countering external mechanical perturbations. Our first experiment tested whether the timing and amplitude of shoulder muscle activity account for interaction torques produced during single-joint elbow movements from different elbow initial orientations and over a range of movement speeds. We found that shoulder muscle activity reliably preceded movement onset and elbow agonist activity, and was scaled to compensate for the magnitude of interaction torques arising because of forearm rotation. Our second experiment tested whether elbow muscles compensate for interaction torques introduced by single-joint wrist movements. We found that elbow muscle activity preceded movement onset and wrist agonist muscle activity, and thus the nervous system predicted interaction torques arising because of hand rotation. Our third and fourth experiments tested whether shoulder muscles compensate for interaction torques introduced by different hand orientations during self-initiated elbow movements and to counter mechanical perturbations that caused pure elbow motion. We found that the nervous system predicted the amplitude and direction of interaction torques, appropriately scaling the amplitude of shoulder muscle activity during self-initiated elbow movements and rapid feedback control. Taken together, our results demonstrate that the nervous system robustly accounts for intersegmental dynamics and that the process is similar across the proximal to distal musculature of the arm as well as between feedforward (i.e., self-initiated) and feedback (i.e., reflexive) control. NEW & NOTEWORTHY Intersegmental dynamics complicate the mapping between applied joint torques and the resulting joint motions. We provide evidence that the nervous system robustly predicts these intersegmental limb dynamics across the shoulder, elbow, and wrist joints during reaching and when countering external perturbations. Copyright © 2017 the American Physiological Society.

  6. Compact Telerobot Hand

    NASA Technical Reports Server (NTRS)

    Rosheim, Mark; Trechsel, Hans

    1993-01-01

    Anthropomorphic telerobotic hand contains actuators, joints, sensors, and complex wiring harnesses. Glove protects interior components of hand from dirt and damage. Imitates motions of human fingers and wrist in lifelike and dexterous way. Incorporates pitch/yaw joints in wrist and head knuckles. Hand modular; so fingers removable, interchangeable units. Feature simplifies servicing and maintenance, which must be done frequently in such complex mechanism.

  7. System characterization of RiceWrist-S: a forearm-wrist exoskeleton for upper extremity rehabilitation.

    PubMed

    Pehlivan, Ali Utku; Rose, Chad; O'Malley, Marcia K

    2013-06-01

    Rehabilitation of the distal joints of the upper extremities is crucial to restore the ability to perform activities of daily living to patients with neurological lesions resulting from stroke or spinal cord injury. Robotic rehabilitation has been identified as a promising new solution, however, much of the existing technology in this field is focused on the more proximal joints of the upper arm. A recently presented device, the RiceWrist-S, focuses on the rehabilitation of the forearm and wrist, and has undergone a few important design changes. This paper first addresses the design improvements achieved in the recent design iteration, and then presents the system characterization of the new device. We show that the RiceWrist-S has capabilities beyond other existing devices, and exhibits favorable system characteristics as a rehabilitation device, in particular torque output, range of motion, closed loop position performance, and high spatial resolution.

  8. Management of an unusual extreme extension contracture of the wrist: role of a custom-designed exercise program in achieving a good range of movement and prevention of recontraction.

    PubMed

    Saraiya, Hemant

    2003-01-01

    An extreme extension contracture of wrist with dorsal contracture of fingers 15 years after burn injury is described. Shortening of extensor tendons, secondary lengthening of flexor tendons, contracted wrist joint capsule, unusual dislocation of carpals, dorsal dislocation of metacarpophalangeal joints of fingers, and provision of sufficient amount of good-quality skin were some of the issues that had to be addressed in treatment. The contracture was released, the carpals and metacarpophalangeal joint dislocations were corrected and fixed with K wires, and the resulting defect was covered with a sheet split-thickness skin graft. An exercise program was designed that consisted of isotonic, isokinetic, and isometric resistance exercises and passive, active, and active-assistive range of motion exercises. These exercises were pursued with the intention of increasing dynamic strength, endurance, and overall functional recovery of the flexor muscles by exploiting the immature nature of early scar tissue. The resultant enhanced flexor muscle power from exercises along with the dynamic splint helped in lengthening of extensor tendons, wrist joint capsule, and split-thickness skin graft. It also helped in resisting the recontracting tendency, with further recovery of good range of wrist and fingers movements, obviating the need of tendon-lengthening surgery and flap coverage. One and half years of follow up didn't show any sign of recontracture, and the patient was able to perform his routine activities. Postburn wrist contractures of such magnitude have been seldom described. Emphasis is put on simple contracture release and a postoperative exercise program.

  9. [Automated Assessment for Bone Age of Left Wrist Joint in Uyghur Teenagers by Deep Learning].

    PubMed

    Hu, T H; Huo, Z; Liu, T A; Wang, F; Wan, L; Wang, M W; Chen, T; Wang, Y H

    2018-02-01

    To realize the automated bone age assessment by applying deep learning to digital radiography (DR) image recognition of left wrist joint in Uyghur teenagers, and explore its practical application value in forensic medicine bone age assessment. The X-ray films of left wrist joint after pretreatment, which were taken from 245 male and 227 female Uyghur nationality teenagers in Uygur Autonomous Region aged from 13.0 to 19.0 years old, were chosen as subjects. And AlexNet was as a regression model of image recognition. From the total samples above, 60% of male and female DR images of left wrist joint were selected as net train set, and 10% of samples were selected as validation set. As test set, the rest 30% were used to obtain the image recognition accuracy with an error range in ±1.0 and ±0.7 age respectively, compared to the real age. The modelling results of deep learning algorithm showed that when the error range was in ±1.0 and ±0.7 age respectively, the accuracy of the net train set was 81.4% and 75.6% in male, and 80.5% and 74.8% in female, respectively. When the error range was in ±1.0 and ±0.7 age respectively, the accuracy of the test set was 79.5% and 71.2% in male, and 79.4% and 66.2% in female, respectively. The combination of bone age research on teenagers' left wrist joint and deep learning, which has high accuracy and good feasibility, can be the research basis of bone age automatic assessment system for the rest joints of body. Copyright© by the Editorial Department of Journal of Forensic Medicine.

  10. A repeated-measures analysis of the effects of soft tissues on wrist range of motion in the extant phylogenetic bracket of dinosaurs: Implications for the functional origins of an automatic wrist folding mechanism in Crocodilia.

    PubMed

    Hutson, Joel David; Hutson, Kelda Nadine

    2014-07-01

    A recent study hypothesized that avian-like wrist folding in quadrupedal dinosaurs could have aided their distinctive style of locomotion with semi-pronated and therefore medially facing palms. However, soft tissues that automatically guide avian wrist folding rarely fossilize, and automatic wrist folding of unknown function in extant crocodilians has not been used to test this hypothesis. Therefore, an investigation of the relative contributions of soft tissues to wrist range of motion (ROM) in the extant phylogenetic bracket of dinosaurs, and the quadrupedal function of crocodilian wrist folding, could inform these questions. Here, we repeatedly measured wrist ROM in degrees through fully fleshed, skinned, minus muscles/tendons, minus ligaments, and skeletonized stages in the American alligator Alligator mississippiensis and the ostrich Struthio camelus. The effects of dissection treatment and observer were statistically significant for alligator wrist folding and ostrich wrist flexion, but not ostrich wrist folding. Final skeletonized wrist folding ROM was higher than (ostrich) or equivalent to (alligator) initial fully fleshed ROM, while final ROM was lower than initial ROM for ostrich wrist flexion. These findings suggest that, unlike the hinge/ball and socket-type elbow and shoulder joints in these archosaurs, ROM within gliding/planar diarthrotic joints is more restricted to the extent of articular surfaces. The alligator data indicate that the crocodilian wrist mechanism functions to automatically lock their semi-pronated palms into a rigid column, which supports the hypothesis that this palmar orientation necessitated soft tissue stiffening mechanisms in certain dinosaurs, although ROM-restricted articulations argue against the presence of an extensive automatic mechanism. Anat Rec, 297:1228-1249, 2014. © 2014 Wiley Periodicals, Inc. © 2014 Wiley Periodicals, Inc.

  11. Man-equivalent telepresence through four fingered human-like hand system

    NASA Technical Reports Server (NTRS)

    Jau, Bruno M.

    1992-01-01

    The author describes a newly developed mechanical hand system. The robot hand is in human-like configuration with a thumb and three fingers, a palm, a wrist, and the forearm in which the hand and wrist actuators are located. Each finger and the wrist has its own active electromechanical compliance system, allowing the joint drive trains to be stiffened or loosened. This mechanism imitates the human muscle dual function of positioner and stiffness controller. This is essential for soft grappling operations. The hand-wrist assembly has 16 finger joints, three wrist joints, and five compliance mechanisms for a total of 24 degrees of freedom. The strength of the hand is roughly half that of the human hand and its size is comparable to a male hand. The hand is controlled through an exoskeleton glove controller that the operator wears. The glove provides the man-machine interface in telemanipulation control mode: it senses the operator's inputs to guide the mechanical hand in hybrid position and force control. The hand system is intended for dexterous manipulations in structured environments. Typical applications will include work in hostile environment such as space operations and nuclear power plants.

  12. Wrist osteoarthritis.

    PubMed

    Laulan, J; Marteau, E; Bacle, G

    2015-02-01

    Painful wrist osteoarthritis can result in major functional impairment. Most cases are related to posttraumatic sequel, metabolic arthropathies, or inflammatory joint disease, although wrist osteoarthritis occurs as an idiopathic condition in a small minority of cases. Surgery is indicated only when conservative treatment fails. The main objective is to ensure pain relief while restoring strength. Motion-preserving procedures are usually preferred, although residual wrist mobility is not crucial to good function. The vast array of available surgical techniques includes excisional arthroplasty, limited and total fusion, total wrist denervation, partial and total arthroplasty, and rib-cartilage graft implantation. Surgical decisions rest on the cause and extent of the degenerative wrist lesions, degree of residual mobility, and patient's wishes and functional demand. Proximal row carpectomy and four-corner fusion with scaphoid bone excision are the most widely used surgical procedures for stage II wrist osteoarthritis secondary to scapho-lunate advanced collapse (SLAC) or scaphoid non-union advanced collapse (SNAC) wrist. Proximal row carpectomy is not indicated in patients with stage III disease. Total wrist denervation is a satisfactory treatment option in patients of any age who have good range of motion and low functional demands; furthermore, the low morbidity associated with this procedure makes it a good option for elderly patients regardless of their range of motion. Total wrist fusion can be used not only as a revision procedure, but also as the primary surgical treatment in heavy manual labourers with wrist stiffness or generalised wrist-joint involvement. The role for pyrocarbon implants, rib-cartilage graft implantation, and total wrist arthroplasty remains to be determined, given the short follow-ups in available studies. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  13. Arthroscopic Synovectomy of Wrist in Rheumatoid Arthritis.

    PubMed

    Shim, Jae Woo; Park, Min Jong

    2017-11-01

    Rheumatoid arthritis (RA) is a systemic inflammatory disorder affecting multiple joints. Wrist involvement is common. Patients with persistent symptoms despite medical management are candidates for surgery. Synovectomy can provide pain relief and functional improvement for rheumatoid wrist. Arthroscopic synovectomy is a safe and reliable method, with minimal postoperative morbidity. This article reviews the role, technique, and results of arthroscopic synovectomy in the rheumatoid wrist. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. In-vivo confirmation of the use of the dart thrower's motion during activities of daily living.

    PubMed

    Brigstocke, G H O; Hearnden, A; Holt, C; Whatling, G

    2014-05-01

    The dart thrower's motion is a wrist rotation along an oblique plane from radial extension to ulnar flexion. We report an in-vivo study to confirm the use of the dart thrower's motion during activities of daily living. Global wrist motion in ten volunteers was recorded using a three-dimensional optoelectronic motion capture system, in which digital infra-red cameras track the movement of retro-reflective marker clusters. Global wrist motion has been approximated to the dart thrower's motion when hammering a nail, throwing a ball, drinking from a glass, pouring from a jug and twisting the lid of a jar, but not when combing hair or manipulating buttons. The dart thrower's motion is the plane of global wrist motion used during most activities of daily living. Arthrodesis of the radiocarpal joint instead of the midcarpal joint will allow better wrist function during most activities of daily living by preserving the dart thrower's motion.

  15. ELBOW AND WRIST INJURIES IN SPORTS

    PubMed Central

    Marmor, Leonard; Bechtol, Charles O.

    1960-01-01

    Any disabling injury of the elbow or wrist should be studied roentgenographically for evidence of fracture which may not be otherwise evident but which may cause permanent disability unless the joint is immobilized for healing. “Tennis elbow” may be treated with physical therapy and analgesic injection but may require splinting or tendon stripping. Elbow sprain can occur in the growing epiphysis but is rare in adults. A jarring fall on the hand may cause fracture or dislocation at the elbow. Full extension of the joint should be restored gradually by active exercise rather than passive or forcible stretching. Fracture at the head of the radius may cause joint hemorrhage with severe pain which can be relieved by aspiration. A displacing fracture at the head of the radius requires removal of the head to prevent arthritic changes. Myositis ossificans contraindicates operation until after it has cleared. Healing of wrist fractures may be facilitated by exercise of the shoulder and elbow while the wrist is still in a cast. Fractures of the navicular bone are difficult to detect even roentgenographically and splinting may have to be done on clinical evidence alone. PMID:14421374

  16. The Manumeter: A non-obtrusive wearable device for monitoring spontaneous use of the wrist and fingers

    PubMed Central

    Rowe, Justin B.; Friedman, Nizan; Bachman, Mark; Reinkensmeyer, David J.

    2014-01-01

    This paper describes the design and pilot testing of a novel device for unobtrusive monitoring of wrist and hand movement through a sensorized watch and a magnetic ring system called the manumeter. The device senses the magnetic field of the ring through two triaxial magnetometers and records the data to onboard memory which can be analyzed later by connecting the watch unit to a computer. Wrist and finger joint angles are estimated using a radial basis function network. We compared joint angle estimates collected using the manumeter to direct measurements taken using a passive exoskeleton and found that after a 60 minute trial, 95% of the radial/ulnar deviation, wrist flexion/extension and finger flexion/extension estimates were within 2.4, 5.8, and 4.7 degrees of their actual values respectively. The device measured angular distance traveled for these three joints within 10.4%, 4.5%, and 14.3 % of their actual values. The manumeter has potential to improve monitoring of real world use of the hand after stroke and in other applications. PMID:24187216

  17. Comparative study of the detection of joint injury in early-stage rheumatoid arthritis by magnetic resonance imaging of the wrist and finger joints and physical examination.

    PubMed

    Tamai, Mami; Kawakami, Atsushi; Iwamoto, Naoki; Kawashiri, Shin-Ya; Fujikawa, Keita; Aramaki, Toshiyuki; Kita, Junko; Okada, Akitomo; Koga, Tomohiro; Arima, Kazuhiko; Kamachi, Makoto; Yamasaki, Satoshi; Nakamura, Hideki; Ida, Hiroaki; Origuchi, Tomoki; Takao, Shoichiro; Aoyagi, Kiyoshi; Uetani, Masataka; Eguchi, Katsumi

    2011-03-01

    To verify whether magnetic resonance imaging (MRI)-proven joint injury is sensitive as compared with joint injury determined by physical examination. MRI of the wrist and finger joints of both hands was examined in 51 early-stage rheumatoid arthritis (RA) patients by both plain and gadolinium diethylenetriaminepentaacetic acid-enhanced MRI. Synovitis, bone edema, and bone erosion (the latter two included as bone lesions at the wrist joints); metacarpophalangeal joints; and proximal interphalangeal joints were considered as MRI-proven joint injury. Japan College of Rheumatology-certified rheumatologists had given a physical examination just before the MRI study. The presence of tender and/or swollen joints in the same fields as MRI was considered as joint injury on physical examination. The association of MRI-proven joint injury with physical examination-proven joint injury was examined. A total of 1,110 sites were available to be examined. MRI-proven joint injury was found in 521 sites, whereas the other 589 sites were normal. Physical examination-proven joint injury was found in 305 sites, which was significantly low as compared with MRI-proven joint injury (P = 1.1 × 10(-12) versus MRI). Joint injury on physical examination was not found in 81.5% of the sites where MRI findings were normal. Furthermore, an association of the severity of MRI-proven joint injury with that of joint injury on physical examination was clearly demonstrated (P = 1.6 × 10(-15), r(s) = 0.469). Our present data suggest that MRI is not only sensitive but accurately reflects the joint injury in patients with early-stage RA. Copyright © 2011 by the American College of Rheumatology.

  18. Quantitative in vivo HR-pQCT imaging of 3D wrist and metacarpophalangeal joint space width in rheumatoid arthritis.

    PubMed

    Burghardt, Andrew J; Lee, Chan Hee; Kuo, Daniel; Majumdar, Sharmila; Imboden, John B; Link, Thomas M; Li, Xiaojuan

    2013-12-01

    In this technique development study, high-resolution peripheral quantitative computed tomography (HR-pQCT) was applied to non-invasively image and quantify 3D joint space morphology of the wrist and metacarpophalangeal (MCP) joints of patients with rheumatoid arthritis (RA). HR-pQCT imaging (82 μm voxel-size) of the dominant hand was performed in patients with diagnosed rheumatoid arthritis (RA, N = 16, age: 52.6 ± 12.8) and healthy controls (CTRL, N = 7, age: 50.1 ± 15.0). An automated computer algorithm was developed to segment wrist and MCP joint spaces. The 3D distance transformation method was applied to spatially map joint space width, and summarized by the mean joint space width (JSW), minimal and maximal JSW (JSW.MIN, JSW.MAX), asymmetry (JSW.AS), and distribution (JSW.SD)-a measure of joint space heterogeneity. In vivo precision was determined for each measure by calculating the smallest detectable difference (SDD) and root mean square coefficient of variation (RMSCV%) of repeat scans. Qualitatively, HR-pQCT images and pseudo-color JSW maps showed global joint space narrowing, as well as regional and focal abnormalities in RA patients. In patients with radiographic JSN at an MCP, JSW.SD was two-fold greater vs. CTRL (p < 0.01), and JSW.MIN was more than two-fold lower (p < 0.001). Similarly, JSW.SD was significantly greater in the wrist of RA patients vs. CTRL (p < 0.05). In vivo precision was highest for JSW (SDD: 100 μm, RMSCV: 2.1%) while the SDD for JSW.MIN and JSW.SD were 370 and 110 μm, respectively. This study suggests that in vivo quantification of 3D joint space morphology from HR-pQCT, could improve early detection of joint damage in rheumatological diseases.

  19. Quantitative In Vivo HR-pQCT Imaging of 3D Wrist and Metacarpophalangeal Joint Space Width In Rheumatoid Arthritis

    PubMed Central

    Burghardt, Andrew J.; Lee, Chan Hee; Kuo, Daniel; Majumdar, Sharmila; Imboden, John B.; Link, Thomas M.; Li, Xiaojuan

    2013-01-01

    In this technique development study, high-resolution peripheral quantitative computed tomography (HR-pQCT) was applied to non-invasively image and quantify 3D joint space morphology of the wrist and metacarpophalangeal (MCP) joints of patients with rheumatoid arthritis (RA). HR-pQCT imaging (82μm voxel-size) of the dominant hand was performed in patients with diagnosed rheumatoid arthritis (RA, N=16, age:52.6±12.8) and healthy controls (CTRL, N=7, age:50.1±15.0). An automated computer algorithm was developed to segment wrist and MCP joint spaces. The 3D distance transformation method was applied to spatially map joint space width, and summarized by the mean joint space width (JSW), minimal and maximal JSW (JSW.MIN, JSW.MAX), asymmetry (JSW.AS), and distribution (JSW.SD) – a measure of joint space heterogeneity. In vivo precision was determined for each measure by calculating the smallest detectable difference (SDD) and root mean square coefficient of variation (RMSCV%) of repeat scans. Qualitatively, HR-pQCT images and pseudo-color JSW maps showed global joint space narrowing, as well as regional and focal abnormalities in RA patients. In patients with radiographic JSN at an MCP, JSW.SD was two-fold greater versus CTRL (p<0.01), and JSW.MIN was more than two-fold lower (p<0.001). Similarly, JSW.SD was significantly greater in the wrist of RA patients versus CTRL (p<0.05). In vivo precision was highest for JSW (SDD: 100μm, RMSCV: 2.1%) while the SDD for JSW.MIN and JSW.SD were 370 and 110μm, respectively. This study suggests that in vivo quantification of 3D joint space morphology from HR-pQCT, could improve early detection of joint damage in rheumatological diseases. PMID:23887879

  20. Triple-axis common-pivot arm wrist device for manipulative applications

    NASA Technical Reports Server (NTRS)

    Kersten, L.; Johnston, J. D.

    1980-01-01

    A concept in manipulator development to overcome the 'weak wrist syndrome', a triple-axis common-pivot arm wrist (TACPAW), is presented. It contains torque motors for actuation, tachometers for measuring rate, and resolvers for position measurements. Furthermore, it provides three degrees of freedom, i.e., pitch, yaw, and roll, in a single manipulator joint. The advantages of this development are increased strength, compactness, and simplification of controls. Designed to be compatible with the protoflight manipulator arm, the joints of TACPAW are back-driveable with + or - 45 deg rotation in pitch, + or - 45 deg in yaw and continuous roll in either direction while delivering 20.5 N-m (15 ft-lb) torque in each of the three movements.

  1. Comminuted Distal Radial Fracture with Large Rotated Palmar Medial Osteochondral Fragment in the Joint.

    PubMed

    Gökkus, Kemal; Sagtas, Ergin; Kesgin, Engin; Aydin, Ahmet Turan

    2018-01-01

    Intra-articular distal radius fractures have long been massively discussed in the literature, but regarding to fractures that possess rotated volar medial fragment in the joint a few amount papers has been written. In this article, we would like to emphasize the significance of the rotated palmar medial (lunate facet) fragment. A 39-year-old man fell from a height of about 3 m and landed on his right outstretched hand; within 40 min, he arrived at our clinic presenting with a severe pain and swelling in his right wrist. Initial X-rays of the wrist revealed dorsal subluxation of the radiocarpal joint with dorsal comminution of the radial articular surface and fracture of the radial styloid process, with (nearly inverted) ~ 140-150° rotation of the palmar medial fragment. With an additional volar approach, the fragment reduced and stabilized with two K-wires and wrist immobilized in external fixator. The patient returned to daily activities without any discomfort and pain after the 1 year from the surgery. Overlooking of palmar rotated osteochondral fragment will cause deficiency to build proper pre-operative strategy to approach the reduction of the fragment. The incompetence of reduction will deteriorate the articular surface and lead to early osteoarthritis of the wrist. The surgeon should detect this fragment and should be familiar with volar approaches of the wrist. Above average surgical experience would be needed for successful reduction.

  2. Smaller external notebook mice have different effects on posture and muscle activity.

    PubMed

    Oude Hengel, Karen M; Houwink, Annemieke; Odell, Dan; van Dieën, Jaap H; Dennerlein, Jack T

    2008-07-01

    Extensive computer mouse use is an identified risk factor for computer work-related musculoskeletal disorders; however, notebook computer mouse designs of varying sizes have not been formally evaluated but may affect biomechanical risk factors. Thirty adults performed a set of mouse tasks with five notebook mice, ranging in length from 75 to 105 mm and in width from 35 to 65 mm, and a reference desktop mouse. An electro-magnetic motion analysis system measured index finger (metacarpophalangeal joint), wrist and forearm postures, and surface electromyography measured muscle activity of three extensor muscles in the forearm and the first dorsal interosseus. The smallest notebook mice were found to promote less neutral postures (up to 3.2 degrees higher metacarpophalangeal joint adduction; 6.5 degrees higher metacarpophalangeal joint flexion, 2.3 degrees higher wrist extension) and higher muscle activity (up to 4.1% of maximum voluntary contraction higher wrist extensor muscle activity). Participants with smaller hands had overall more non-neutral postures than participants with larger hands (up to 5.6 degrees higher wrist extension and 5.9 degrees higher pronation); while participants with larger hands were more influenced by the smallest notebook mice (up to 3.6 degrees higher wrist extension and 5.5% of maximum voluntary contraction higher wrist extensor values). Self-reported ratings showed that while participants preferred smaller mice for portability; larger mice scored higher on comfort and usability. The smallest notebook mice increased the intensity of biomechanical exposures. Longer term mouse use could enhance these differences, having a potential impact on the prevention of work-related musculoskeletal disorders.

  3. Kinematic rate control of simulated robot hand at or near wrist singularity

    NASA Technical Reports Server (NTRS)

    Barker, K.; Houck, J. A.; Carzoo, S. W.

    1985-01-01

    A robot hand should obey movement commands from an operator on a computer program as closely as possible. However, when two of the three rotational axes of the robot wrist are colinear, the wrist loses a degree of freedom, and the usual resolved rate equations (used to move the hand in response to an operator's inputs) are indeterminant. Furthermore, rate limiting occurs in close vicinity to this singularity. An analysis shows that rate limiting occurs not only in the vicinity of this singularity but also substantially away from it, even when the operator commands rotational rates of the robot hand that are only a small percentage of the operational joint rate limits. Therefore, joint angle rates are scaled when they exceed operational limits in a real time simulation of a robot arm. Simulation results show that a small dead band avoids the wrist singularity in the resolved rate equations but can introduce a high frequency oscillation close to the singularity. However, when a coordinated wrist movement is used in conjunction with the resolved rate equations, the high frequency oscillation disappears.

  4. Joint Preservation of the Wrist Using Articulated Distraction Arthroplasty: A Case Report of a Novel Technique

    PubMed Central

    Fletcher, Matt D. A.

    2015-01-01

    Distraction arthroplasty of the ankle, elbow, and hip has become widely accepted and used within the orthopaedic community with excellent initial results which appear sustained. To date it has not been applied to the wrist in the same manner. A novel technique, drawn upon past success of articulated ankle distraction and static wrist distraction, was devised and evaluated by application of articulated wrist distraction performed over a 12-week period in a patient with poor functional outcome following limited wrist fusion. Posttreatment results showed improvement in range of motion (100-degree arc), subjective pain, and functional outcome measures (DASH 21.7, Mayo Wrist Score 80) comparable or better than either limited wrist fusion or proximal row carpectomy. Articulated wrist distraction initially appears to be a promising therapeutic option for the management of the stiff and painful wrist to maintain maximal function for which formal wrist arthrodesis may be the only alternative. PMID:25767728

  5. Whole-body MRI assessment of disease activity and structural damage in rheumatoid arthritis: first step towards an MRI joint count.

    PubMed

    Axelsen, Mette Bjørndal; Eshed, Iris; Duer-Jensen, Anne; Møller, Jakob M; Pedersen, Susanne Juhl; Østergaard, Mikkel

    2014-05-01

    The aim of this study was to investigate the ability of whole-body MRI (WBMRI) to visualize inflammation [synovitis, bone marrow oedema (BME) and enthesitis] and structural damage in patients with RA. The 3T WBMR images were acquired in a head-to-toe scan in 20 patients with RA and at least one swollen or tender joint. Short Tau Inversion Recovery and pre- and post-contrast T1-weighted images were evaluated for readability and the presence/absence of inflammation (synovitis, BME and enthesitis) and structural damage (erosions and fat infiltrations) in 76 peripheral joints, 30 entheseal sites and in the spine. The readability was >70% for all individual joints, except for the most peripheral joints of the hands and feet. Synovitis was most frequent in the wrist, first tarsometatarsal, first CMC joints and glenohumeral joints (67-61%); BME in the wrist, CMC, acromioclavicular and glenohumeral joints (45-35%) and erosions in the wrist, MTP and CMC joints (19-16%). Enthesitis at ≥ 1 site was registered in 16 patients. BME was frequently seen in the cervical (20%) but not the thoracic and lumbar spine, while fat infiltrations and erosions were rare. The intrareader agreement was high (85-100%) for all pathologies. The agreement between WBMRI and clinical findings was low. Peripheral and axial inflammation and structural damage at joints and entheses was frequently identified by WBMRI, and more frequently than by clinical examination. WBMRI is a promising tool for evaluation of the total inflammatory load of inflammation (an MRI joint count) and structural damage in RA patients.

  6. Effect of hammer mass on upper extremity joint moments.

    PubMed

    Balendra, Nilanthy; Langenderfer, Joseph E

    2017-04-01

    This study used an OpenSim inverse-dynamics musculoskeletal model scaled to subject-specific anthropometrics to calculate three-dimensional intersegmental moments at the shoulder, elbow and wrist while 10 subjects used 1 and 2 lb hammers to drive nails. Motion data were collected via an optoelectronic system and the interaction of the hammer with nails was recorded with a force plate. The larger hammer caused substantial increases (50-150%) in moments, although increases differed by joint, anatomical component, and significance of the effect. Moment increases were greater in cocking and strike/follow-through phases as opposed to swinging and may indicate greater potential for injury. Compared to shoulder, absolute increases in peak moments were smaller for elbow and wrist, but there was a trend toward larger relative increases for distal joints. Shoulder rotation, elbow varus-valgus and pronation-supination, and wrist radial-ulnar deviation and rotation demonstrated large relative moment increases. Trial and phase durations were greater for the larger hammer. Changes in moments and timing indicate greater loads on musculoskeletal tissues for an extended period with the larger hammer. Additionally, greater variability in timing with the larger hammer, particularly for cocking phase, suggests differences in control of the motion. Increased relative moments for distal joints may be particularly important for understanding disorders of the elbow and wrist associated with hammer use. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Traumatic synovitis in a classical guitarist: a study of joint laxity.

    PubMed

    Bird, H A; Wright, V

    1981-04-01

    A classical guitarist performing for at least 5 hours each day developed a traumatic synovitis at the left wrist joint that was first erroneously considered to be rheumatoid arthritis. Comparison with members of the same guitar class suggested that unusual joint laxity of the fingers and wrist, probably inherited from the patient's father, was of more importance in the aetiology of the synovitis than a wide range of movement acquired by regular practice. Hyperextension of the metacarpophalangeal joint of the left index finger, quantified by the hyperextensometer, was less marked in the guitarists than in 100 normal individuals. This may be attributed to greater muscular control of the fingers. Lateral instability in the loaded joint may be the most important factor in the aetiology of traumatic synovitis.

  8. Traumatic synovitis in a classical guitarist: a study of joint laxity.

    PubMed Central

    Bird, H A; Wright, V

    1981-01-01

    A classical guitarist performing for at least 5 hours each day developed a traumatic synovitis at the left wrist joint that was first erroneously considered to be rheumatoid arthritis. Comparison with members of the same guitar class suggested that unusual joint laxity of the fingers and wrist, probably inherited from the patient's father, was of more importance in the aetiology of the synovitis than a wide range of movement acquired by regular practice. Hyperextension of the metacarpophalangeal joint of the left index finger, quantified by the hyperextensometer, was less marked in the guitarists than in 100 normal individuals. This may be attributed to greater muscular control of the fingers. Lateral instability in the loaded joint may be the most important factor in the aetiology of traumatic synovitis. Images PMID:7224687

  9. 21 CFR 888.3810 - Wrist joint ulnar (hemi-wrist) polymer prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... polyethylene intended to be implanted into the intramedullary canal of the bone and held in place by a suture. Its purpose is to cover the resected end of the distal ulna to control bone overgrowth and to provide...

  10. 21 CFR 888.3810 - Wrist joint ulnar (hemi-wrist) polymer prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... polyethylene intended to be implanted into the intramedullary canal of the bone and held in place by a suture. Its purpose is to cover the resected end of the distal ulna to control bone overgrowth and to provide...

  11. 21 CFR 888.3810 - Wrist joint ulnar (hemi-wrist) polymer prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... polyethylene intended to be implanted into the intramedullary canal of the bone and held in place by a suture. Its purpose is to cover the resected end of the distal ulna to control bone overgrowth and to provide...

  12. 21 CFR 888.3810 - Wrist joint ulnar (hemi-wrist) polymer prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... polyethylene intended to be implanted into the intramedullary canal of the bone and held in place by a suture. Its purpose is to cover the resected end of the distal ulna to control bone overgrowth and to provide...

  13. 21 CFR 888.3810 - Wrist joint ulnar (hemi-wrist) polymer prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... polyethylene intended to be implanted into the intramedullary canal of the bone and held in place by a suture. Its purpose is to cover the resected end of the distal ulna to control bone overgrowth and to provide...

  14. Automated joint space width quantification of hand and wrist joints: a proof of concept study.

    PubMed

    Huo, Yinghe; Veldhuizen, Renske D; van der Heijde, Desiree M; Besselink, Nick J; Jacobs, Johannes W G; van Laar, Jacob M; Viergever, Max A; Vincken, Koen L; Lafeber, Floris P; de Hair, Maria J H

    2016-01-01

    To compare as proof of concept the sensitivity to change of automated quantification of radiographic wrist and hand joint space width (JSW) with scoring JSW according to the Sharp/van der Heijde scoring method (SHS) in two strategy groups of a treat-to-target and tight-control early rheumatoid arthritis (RA) study. Digital radiographs were assessed for JSW changes of 134 patients of the 236 patients participating in the second Computer Assisted Management in Early Rheumatoid Arthritis trial, of whom both baseline and year 2 radiographs were available (year 1 radiographs n=125). Of those 134 patients, 70 started with methotrexate and prednisone (MTX+Pred) and 64 with MTX and placebo (MTX+Plac). JSW change over 1 and 2 years of the hands and wrists was assessed, applying both the joint space narrowing (JSN) subscore of the SHS by 2 readers and the automated assessment with the JSW quantification software 'JSQ'. For both methods, progression of JSW change of the hand and wrist was analysed using linear mixed modelling (dependent variable 'JSW', factor 'strategy group', covariate 'follow-up time in years', interaction term 'strategy group*follow-up time'; radiographs of baseline, year 1 and year 2 were used). For each method the standardised mean difference (SMD) for the change in JSW from baseline to year 2 between the treatment strategies was obtained using a non-parametric method. Patient characteristics of the current subpopulation were similar to those of the whole study population. JSN of the hand and wrist according to SHS at 2 years was present in 16 vs. 23% in the MTX+Pred group vs. the MTX+Plac group. The mean yearly progression rates of JSW change of the hands and wrists using JSQ were -0.00mm (95% confidence interval (CI) -0.01; 0.01) for MTX+Pred vs. -0.02mm (95%CI -0.03; -0.01) for MTX+Plac, p=0.045, and using SHS JSN they were 0.19 units (95%CI 0.09; 0.30) vs. 0.30 units (95%CI 0.14; 0.45) for MTX+Pred vs. MTX+Plac, p=0.271. The SMD for the change from baseline to year 2 between the treatment strategies was 0.37 for JSQ and 0.13 for SHS JSN. In this proof of concept study the yearly progression rate of JSW change of hand and wrist joints, according to the automated JSW quantification software package 'JSQ', was higher in the group initiating MTX+Plac than in the group initiating MTX+Pred. A similar trend was seen with the JSN assessment according to the SHS method of the hand and wrist. However, JSN of the hand and wrist according to SHS, the current gold standard to assess radiographic progression, was seen in only about 20%. Therefore, further studies are needed to conclude firmly that JSQ should be incorporated into quantitative scoring of radiographs in RA.

  15. Three-dimensional and thermal surface imaging produces reliable measures of joint shape and temperature: a potential tool for quantifying arthritis

    PubMed Central

    Spalding, Steven J; Kwoh, C Kent; Boudreau, Robert; Enama, Joseph; Lunich, Julie; Huber, Daniel; Denes, Louis; Hirsch, Raphael

    2008-01-01

    Introduction The assessment of joints with active arthritis is a core component of widely used outcome measures. However, substantial variability exists within and across examiners in assessment of these active joint counts. Swelling and temperature changes, two qualities estimated during active joint counts, are amenable to quantification using noncontact digital imaging technologies. We sought to explore the ability of three dimensional (3D) and thermal imaging to reliably measure joint shape and temperature. Methods A Minolta 910 Vivid non-contact 3D laser scanner and a Meditherm med2000 Pro Infrared camera were used to create digital representations of wrist and metacarpalphalangeal (MCP) joints. Specialized software generated 3 quantitative measures for each joint region: 1) Volume; 2) Surface Distribution Index (SDI), a marker of joint shape representing the standard deviation of vertical distances from points on the skin surface to a fixed reference plane; 3) Heat Distribution Index (HDI), representing the standard error of temperatures. Seven wrists and 6 MCP regions from 5 subjects with arthritis were used to develop and validate 3D image acquisition and processing techniques. HDI values from 18 wrist and 9 MCP regions were obtained from 17 patients with active arthritis and compared to data from 10 wrist and MCP regions from 5 controls. Standard deviation (SD), coefficient of variation (CV), and intraclass correlation coefficients (ICC) were calculated for each quantitative measure to establish their reliability. CVs for volume and SDI were <1.3% and ICCs were greater than 0.99. Results Thermal measures were less reliable than 3D measures. However, significant differences were observed between control and arthritis HDI values. Two case studies of arthritic joints demonstrated quantifiable changes in swelling and temperature corresponding with changes in symptoms and physical exam findings. Conclusion 3D and thermal imaging provide reliable measures of joint volume, shape, and thermal patterns. Further refinement may lead to the use of these technologies to improve the assessment of disease activity in arthritis. PMID:18215307

  16. The effect of lunate position on range of motion after a four-corner arthrodesis: a biomechanical simulation study.

    PubMed

    Dvinskikh, N A; Blankevoort, L; Strackee, S D; Grimbergen, C A; Streekstra, G J

    2011-04-29

    A four-corner arthrodesis of the wrist is a salvage procedure for the treatment of specific wrist disorders, to achieve a movable, stable and pain free joint. However, a partial arthrodesis limits the postoperative range of motion (ROM). The goal of this study is to understand the mechanism of the reduction of the ROM and to evaluate the effect of the orientation of the lunate in the four-corner arthrodesis on the range of motion by using a biomechanical model, containing articular contacts and ligaments. Multi-body models of a normal wrist and a four-corner arthrodesis wrist with different orientation of the lunate were used for simulations of flexion-extension motion (FEM) and radial-ulnar deviation motion (RUD). The ROM of the postoperative wrist was reduced from 145° to 82° of the total arc of FEM and from 73° to 41.5° of the total arc of RUD. The model simulations show that the range of motion reduction is caused by overtension of the extrinsic wrist ligaments. Different positioning of the lunate changes the balance between the contact forces and ligament forces in the wrist. This explains the effect on the postoperative range of motion. The 20° flexed lunate did not give any gain in the extension motion of the wrist, caused joint luxation in flexion and limitation in RUD. The 30° extended lunate caused overtension of the extrinsic ligaments attached to the lunate. The ROM in this case is dramatically reduced. The model simulations suggest that the neutral position of the lunate seems to be most favorable for mobility of the wrist after a four-corner arthrodesis procedure. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Flexible and static wrist units in upper limb prosthesis users: functionality scores, user satisfaction and compensatory movements.

    PubMed

    Deijs, M; Bongers, R M; Ringeling-van Leusen, N D M; van der Sluis, C K

    2016-03-15

    The current study examines the relevance of prosthetic wrist movement to facilitate activities of daily living or to prevent overuse complaints. Prosthesis hands with wrist flexion/extension capabilities are commercially available, but research on the users' experiences with flexible wrists is limited. In this study, eight transradial amputees using a myoelectric prosthesis tested two prosthesis wrists with flexion/extension capabilities, the Flex-wrist (Otto Bock) and Multi-flex wrist (Motion Control), in their flexible and static conditions. Differences between the wrists were assessed on the levels of functionality, user satisfaction and compensatory movements after two weeks use. No significant differences between flexible and static wrist conditions were found on activity performance tests and standardized questionnaires on satisfaction. Inter-individual variation was remarkably large. Participants' satisfaction tended to be in favour of flexible wrists. All participants but one indicated that they would choose a prosthesis hand with wrist flexion/extension capabilities if allowed a new prosthesis. Shoulder joint angles, reflecting compensatory movements, showed no clear differences between wrist conditions. Overall, positive effects of flexible wrists are hard to objectify. Users seem to be more satisfied with flexible wrists. A person's needs, work and prosthesis skills should be taken into account when prescribing a prosthesis wrist. Nederlands Trial Register NTR3984 .

  18. Techniques of Force and Pressure Measurement in the Small Joints of the Wrist.

    PubMed

    Schreck, Michael J; Kelly, Meghan; Canham, Colin D; Elfar, John C

    2018-01-01

    The alteration of forces across joints can result in instability and subsequent disability. Previous methods of force measurements such as pressure-sensitive films, load cells, and pressure-sensing transducers have been utilized to estimate biomechanical forces across joints and more recent studies have utilized a nondestructive method that allows for assessment of joint forces under ligamentous restraints. A comprehensive review of the literature was performed to explore the numerous biomechanical methods utilized to estimate intra-articular forces. Methods of biomechanical force measurements in joints are reviewed. Methods such as pressure-sensitive films, load cells, and pressure-sensing transducers require significant intra-articular disruption and thus may result in inaccurate measurements, especially in small joints such as those within the wrist and hand. Non-destructive methods of joint force measurements either utilizing distraction-based joint reaction force methods or finite element analysis may offer a more accurate assessment; however, given their recent inception, further studies are needed to improve and validate their use.

  19. [Clinical observation on the effect of joint mobilization in treating elderly patients after distal radius fractures operation].

    PubMed

    Jia, Xue-Feng; Cai, Hong-Xin; Lin, Ge-Sheng; Fang, Ji-Shi; Wang, Yong; Wu, Zhi-Yong; Tu, Xu-Hui

    2017-07-25

    To investigate the effect of joint mobilization on postoperative wrist joint function, pain and grip strength for elderly patients with distal radius fracture. From January 2015 to June 2016, a total of 67 elderly patients with distal radius fracture were randomly divided into routine exercise group and joint mobilization group. Among them, 37 patients in the routine exercise group underwent conventional distal radius fracture postoperative joint function exercise regimen, including 16 males and 21 females with a mean age of (67.8±3.2) years old ranging from 60 to 72 years old;the injured side was dominant in 23 cases and non-dominant in 14 cases;injury mechanism was fall in 26 cases, traffic accident in 11 cases; for AO type, 6 cases were type B3, 18 cases were type C1, 7 cases were type C2, 6 cases was type C3. Other 30 patients in the joint mobilization group underwent joint mobilization on the basis of the routine exercise group including 14 males and 16 females with a mean age of (67.1±4.0) years old ranging from 61 to 74 years old; the injured side was dominant in 21 cases and non-dominant in 9 cases;injury mechanism was fall in 25 cases, traffic accident in 5 cases;for AO type, 8 cases were type B3, 13 cases were type C1, 6 cases were type C2, 9 cases were type C3. The wrist joint activity, Gartland-Werley wrist joint function score, VAS pain score and grip strength were observed at 3 months afrer treatment. After 3 months' treatment, the VAS in the routine exercise group was higher than that of the joint mobilization group ( P <0.05). The grip strength of affected side in both groups were lower than that of contralateral side, but the average grip strength of affected side in joint mobilization group was higher than that in routine exercise group( P <0.05). In routine exercise group, the average angle of flexion, extension, radial deviation were significantly higher than those of joint mobilization group( P <0.05). But ulnar deviation angle in routine exercise group compared with joint mobilization group had no significant difference ( P >0.05). In the comparison of each item of Gartland-Werley, there was no significant difference between two groups in residual deformity and complication( P >0.05); the average score of subjective score, objective score and total score in routine exercise group were significantly higher than those of the joint mobilization group ( P <0.05). The wrist function Gartland-Werley score in routine exercise group after treatment was excellent in 21 cases, good in 10, 6 in fair, while in joint mobilization group, excellent in 23, good in 6, fair in 1( P <0.05). The application of joint mobilization in the treatment of elderly patients with distal radius fracture can improve the joint activity and obtain better wrist function after surgery.

  20. Joint positions matter for ultrasound examination of RA patients-increased power Doppler signal in neutral versus flat position of hands.

    PubMed

    Husic, Rusmir; Lackner, Angelika; Stradner, Martin H; Hermann, Josef; Dejaco, Christian

    2017-08-01

    Position of joints might influence the result of US examination in patients with RA. The purpose of this work was to compare grey-scale (GS) and power Doppler (PWD) findings obtained in neutral vs flat position of hands. A cross-sectional study of 42 RA patients with active disease. Two dimensional and 3D sonography of wrists and MCP joints were conducted in two different joint positions: neutral position, which is a slight flexion of the fingers with relaxed extensor muscles; and flat position, where all palm and volar sides of fingers touch the Table. Two dimensional GS synovitis (GSS) and PWD signals were scored semi-quantitatively (0-3). For 3D sonography, the percentage of PWD voxels within a region of interest was calculated. GSS was not quantified using 3D sonography. Compared with neutral position, 2D PWD signals disappeared in 28.3% of joints upon flattening. The median global 2D PWD score (sum of all PWD scores of an individual patient) decreased from 8 to 3 ( P < 0.001), and the global 3D PWD voxel score from 3.8 to 0.9 ( P < 0.001). The reduction of PWD scores was similar in all joints (2D: minus 50%, 3D: minus 66.4-80.1%). Inter- and intrareader agreement of PWD results was good (intraclass correlation coefficient: 0.75-0.82). In RA, a neutral position of the hands is linked to a higher sensitivity of 2D and 3D sonography in detecting PWD signals at wrists and MCP joints, compared with a flat position. Standardization of the scanning procedure is essential for obtaining comparable US results in RA patients in trials and clinical routines. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  1. Comparison between open and arthroscopic-assisted foveal triangular fibrocartilage complex repair for post-traumatic distal radio-ulnar joint instability.

    PubMed

    Luchetti, R; Atzei, A; Cozzolino, R; Fairplay, T; Badur, N

    2014-10-01

    The aim of this study was to assess the objective and subjective functional outcomes after foveal reattachment of proximal or complete ulnar-sided triangular fibrocartilage complex lesions by two surgical procedures: an open technique or an arthroscopically assisted repair. The study was done prospectively on 49 wrists affected by post-traumatic distal radio-ulnar joint instability. Twenty-four patients were treated with the open technique (Group 1) and 25 by the arthroscopically assisted technique (Group 2). Magnetic resonance imaging demonstrated a clear foveal detachment of the triangular fibrocartilage complex in 67% of the cases. Arthroscopy showed a positive ulnar-sided detachment of the triangular fibrocartilage complex (positive hook test) in all cases. Distal radio-ulnar joint stability was obtained in all but five patients at a mean follow-up of 6 months. Both groups had improvement of all parameters with significant differences in wrist pain scores, Mayo wrist score, Disability of the Arm, Shoulder and Hand questionnaire and Patient-Rated Wrist/Hand Evaluation questionnaire scores. There were no significant post-operative differences between the two groups in the outcome parameters except for the Disability of the Arm Shoulder and Hand questionnaire score, which was significantly better in Group 2 (p < 0.001). © The Author(s) 2013.

  2. Passive stiffness of coupled wrist and forearm rotations.

    PubMed

    Drake, Will B; Charles, Steven K

    2014-09-01

    Coordinated movement requires that the neuromuscular system account and compensate for movement dynamics. One particularly complex aspect of movement dynamics is the interaction that occurs between degrees of freedom (DOF), which may be caused by inertia, damping, and/or stiffness. During wrist rotations, the two DOF of the wrist (flexion-extension and radial-ulnar deviation, FE and RUD) are coupled through interaction torques arising from passive joint stiffness. One important unanswered question is whether the DOF of the forearm (pronation-supination, PS) is coupled to the two DOF of the wrist. Answering this question, and understanding the dynamics of wrist and forearm rotations in general, requires knowledge of the stiffness encountered during rotations involving all three DOF (PS, FE, and RUD). Here we present the first-ever measurement of the passive stiffness encountered during simultaneous wrist and forearm rotations. Using a wrist and forearm robot, we measured coupled wrist and forearm stiffness in 10 subjects and present it as a 3-by-3 stiffness matrix. This measurement of passive wrist and forearm stiffness will enable future studies investigating the dynamics of wrist and forearm rotations, exposing the dynamics for which the neuromuscular system must plan and compensate during movements involving the wrist and forearm.

  3. Inversion Of Jacobian Matrix For Robot Manipulators

    NASA Technical Reports Server (NTRS)

    Fijany, Amir; Bejczy, Antal K.

    1989-01-01

    Report discusses inversion of Jacobian matrix for class of six-degree-of-freedom arms with spherical wrist, i.e., with last three joints intersecting. Shows by taking advantage of simple geometry of such arms, closed-form solution of Q=J-1X, which represents linear transformation from task space to joint space, obtained efficiently. Presents solutions for PUMA arm, JPL/Stanford arm, and six-revolute-joint coplanar arm along with all singular points. Main contribution of paper shows simple geometry of this type of arms exploited in performing inverse transformation without any need to compute Jacobian or its inverse explicitly. Implication of this computational efficiency advanced task-space control schemes for spherical-wrist arms implemented more efficiently.

  4. KSC-05pd2466

    NASA Image and Video Library

    2005-11-07

    KENNEDY SPACE CENTER, FLA. - In the Orbiter Processing Facility Bay 1 at NASA Kennedy Space Center, a crane lifts the remote manipulator system boom out of Atlantis’ payload bay. The boom will be temporarily stored. The RMS includes the electromechanical arm that maneuvers a payload from the payload bay of the orbiter to its deployment position and then releases it. It can also grapple a free-flying payload, maneuver it to the payload bay of the orbiter and berth it in the orbiter. The RMS arm is 50 feet 3 inches long and 15 inches in diameter. It weighs 905 pounds, and the total system weighs 994 pounds. The RMS has six joints that correspond roughly to the joints of the human arm, with shoulder yaw and pitch joints; an elbow pitch joint; and wrist pitch, yaw and roll joints. The end effector is the unit at the end of the wrist that actually grabs, or grapples, the payload.

  5. KSC-05pd2467

    NASA Image and Video Library

    2005-11-07

    KENNEDY SPACE CENTER, FLA. - In the Orbiter Processing Facility Bay 1 at NASA Kennedy Space Center, the remote manipulator system boom is lifted away from Atlantis’ payload bay and will be temporarily stored. The RMS includes the electromechanical arm that maneuvers a payload from the payload bay of the orbiter to its deployment position and then releases it. It can also grapple a free-flying payload, maneuver it to the payload bay of the orbiter and berth it in the orbiter. The RMS arm is 50 feet 3 inches long and 15 inches in diameter. It weighs 905 pounds, and the total system weighs 994 pounds. The RMS has six joints that correspond roughly to the joints of the human arm, with shoulder yaw and pitch joints; an elbow pitch joint; and wrist pitch, yaw and roll joints. The end effector is the unit at the end of the wrist that actually grabs, or grapples, the payload.

  6. Management of a Complex, Multioperated Intra-Articular Distal Radius Fracture

    PubMed Central

    Giwa, Lolade; Spacey, Kate; Packer, Greg

    2015-01-01

    Background Intra-articular distal radius fractures can have many complications, including radiocarpal osteoarthritis and distal radioulnar joint (DRUJ) dysfunction leading to pain and restricted wrist function. Case Description We describe the case of a 38-year-old patient who sustained a left distal radius intra-articular fracture, which was treated with volar plating. She developed pain from the radiocarpal joint as a result of intra-articular malunion and was listed for total wrist fusion. On the day of surgery this was converted to a Darrach procedure for minor DRUJ symptoms. This resulted in pain from the DRUJ as a result of instability, in addition to persisting radiocarpal arthritis pain. Due to her subsequent poor wrist function, she presented to the authors and underwent DRUJ arthroplasty with a proximally placed Scheker prosthesis to deal with her DRUJ symptoms and, later, a KinematX radiocarpal hemiarthroplasty for her radiocarpal symptoms. She remains happy with her outcome at 36-month follow-up. Literature Review The complications of the Darrach procedure include painful radioulnar convergence and wrist instability. The Scheker prosthesis allows restoration of stability of the DRUJ with good outcomes and 100% 5-year survival in one series. Sparing the midcarpal joint, the KinematX hemiarthroplasty allows preservation of the dart thrower's motion arc, which is key in many complex wrist movements and functions. Clinical Relevance This case highlights the negative consequences of distal ulna resection and shows both the Scheker and KinematX prostheses as viable, effective means to restore function to young, active patients with posttraumatic radiocarpal arthritis and/or instability. PMID:26261743

  7. A novel method to replicate the kinematics of the carpus using a six degree-of-freedom robot.

    PubMed

    Fraysse, François; Costi, John J; Stanley, Richard M; Ding, Boyin; McGuire, Duncan; Eng, Kevin; Bain, Gregory I; Thewlis, Dominic

    2014-03-21

    Understanding the kinematics of the carpus is essential to the understanding and treatment of wrist pathologies. However, many of the previous techniques presented are limited by non-functional motion or the interpolation of points from static images at different postures. We present a method that has the capability of replicating the kinematics of the wrist during activities of daily living using a unique mechanical testing system. To quantify the kinematics of the carpal bones, we used bone pin-mounted markers and optical motion capture methods. In this paper, we present a hammering motion as an example of an activity of daily living. However, the method can be applied to a wide variety of movements. Our method showed good accuracy (1.0-2.6°) of in vivo movement reproduction in our ex vivo model. Most carpal motion during wrist flexion-extension occurs at the radiocarpal level while in ulnar deviation the motion is more equally shared between radiocarpal and midcarpal joints, and in radial deviation the motion happens mainly at the midcarpal joint. For all rotations, there was more rotation of the midcarpal row relative to the lunate than relative to the scaphoid or triquetrum. For the functional motion studied (hammering), there was more midcarpal motion in wrist extension compared to pure wrist extension while radioulnar deviation patterns were similar to those observed in pure wrist radioulnar deviation. Finally, it was found that for the amplitudes studied the amount of carpal rotations was proportional to global wrist rotations. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Conservative treatment of an acute traumatic extensor carpi ulnaris tendon subluxation in a collegiate basketball player: a case report.

    PubMed

    Patterson, Steve M; Picconatto, William J; Alexander, Julie A; Johnson, Rachel L

    2011-01-01

    To present the case of an acute traumatic extensor carpi ulnaris (ECU) subluxation in a National Collegiate Athletic Association Division II female basketball player. The ECU tendon is stabilized in the ulnar groove by a subsheath located inferior to the extensor retinaculum. The subsheath can be injured with forced supination, ulnar deviation, and wrist flexion, resulting in the ECU tendon subluxing in the palmar and ulnar directions during wrist circumduction. Several methods of intervention exist, but controversy remains on how to best treat this condition. Distal ulnar fracture, ulnar collateral ligament sprain, triangular fibrocartilage complex lesion, lunotriquetral instability, distal radioulnar joint injury, pisotriquetral joint injury, ECU tendinopathy or subluxation. The wrist was placed in a short-arm cast in slight extension and radial deviation for 4 weeks. At that time, the patient was still able to actively sublux the ECU tendon, so a long-arm cast was applied with the wrist in slight extension, radial deviation, and pronation for an additional 4 weeks. The ECU tendon was then found to be stable. She wore a rigid wrist brace for 3 more weeks while she pursued rehabilitation. At the final follow-up appointment, the ECU tendon remained stable, and the wrist was asymptomatic. Subluxations of the ECU are rare. If the patient does not improve with conservative measures, surgical intervention is warranted to repair the sixth dorsal compartment. A long-arm cast with the elbow flexed to 90° and the wrist in approximately 30° of extension, radial deviation, and pronation was appropriate treatment for this type of injury.

  9. Acute hand and wrist injuries sustained during recreational mountain biking: a prospective study.

    PubMed

    Bush, Kevin; Meredith, Steve; Demsey, Daniel

    2013-12-01

    Recreational mountain biking continues to increase in popularity and is a significant source of traumatic injury, including injuries to the hand and wrist. A prospective survey of all hand and wrist injuries sustained while participating in recreational mountain biking presenting to the emergency department at the Municipality of Whistler and the District of Squamish was conducted over a 12-month consecutive period. An analysis of 765 unique emergency department visits with 1,079 distinct injuries was performed. Of these injuries, 511 were sustained to the upper limb. Injury to the metacarpal and metacarpal phalangeal joints was the most common hand injury (52) followed by proximal phalanx and proximal interphalangeal joint (20). Mountain biking is a frequent source of a variety of upper limb trauma, and preventative efforts are necessary to minimize the burden of these injuries.

  10. Water and fat separation in real-time MRI of joint movement with phase-sensitive bSSFP.

    PubMed

    Mazzoli, Valentina; Nederveen, Aart J; Oudeman, Jos; Sprengers, Andre; Nicolay, Klaas; Strijkers, Gustav J; Verdonschot, Nico

    2017-07-01

    To introduce a method for obtaining fat-suppressed images in real-time MRI of moving joints at 3 Tesla (T) using a bSSFP sequence with phase detection to enhance visualization of soft tissue structures during motion. The wrist and knee of nine volunteers were imaged with a real-time bSSFP sequence while performing dynamic tasks. For appropriate choice of sequence timing parameters, water and fat pixels showed an out-of-phase behavior, which was exploited to reconstruct water and fat images. Additionally, a 2-point Dixon sequence was used for dynamic imaging of the joints, and resulting water and fat images were compared with our proposed method. The joints could be visualized with good water-fat separation and signal-to-noise ratio (SNR), while maintaining a relatively high temporal resolution (5 fps in knee imaging and 10 fps in wrist imaging). The proposed method produced images of moving joints with higher SNR and higher image quality when compared with the Dixon method. Water-fat separation is feasible in real-time MRI of moving knee and wrist at 3 T. PS-bSSFP offers movies with higher SNR and higher diagnostic quality when compared with Dixon scans. Magn Reson Med 78:58-68, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  11. Design and control of a 3-DOF rehabilitation robot for forearm and wrist.

    PubMed

    Lincong Luo; Liang Peng; Zengguang Hou; Weiqun Wang

    2017-07-01

    This paper presents a 3-DOF compact rehabilitation robot, involving mechanical structure design, control system design and gravity compensation analysis. The robot can simultaneously provide assistance for pronation/supination(P/S), flexion/extension(F/E) and adduction/abduction(A/A) joints rehabilitation training. The P/S and F/E joints are designed to be driven by cable transmission to gain a high backdrivability, and an adjustment plate is adopted to decrease the distance between the rotation axis of F/E joint of the human wrist and the robot. In addition, gravity compensation is considered to offset the impact of self-gravity on the performance of the controller. A "moving window" control strategy based on impedance control is proposed and implemented on the robot. A comparison between the "moving window" control and classical impedance control indicates that the former has more potential to stimulate the voluntary efforts of the participant, and has a less limitation moving in a fixed reference trajectory. Meanwhile, the results also validate the feasibility and safety of the wrist robot system.

  12. Developing a multi-joint upper limb exoskeleton robot for diagnosis, therapy, and outcome evaluation in neurorehabilitation.

    PubMed

    Ren, Yupeng; Kang, Sang Hoon; Park, Hyung-Soon; Wu, Yi-Ning; Zhang, Li-Qun

    2013-05-01

    Arm impairments in patients post stroke involve the shoulder, elbow and wrist simultaneously. It is not very clear how patients develop spasticity and reduced range of motion (ROM) at the multiple joints and the abnormal couplings among the multiple joints and the multiple degrees-of-freedom (DOF) during passive movement. It is also not clear how they lose independent control of individual joints/DOFs and coordination among the joints/DOFs during voluntary movement. An upper limb exoskeleton robot, the IntelliArm, which can control the shoulder, elbow, and wrist, was developed, aiming to support clinicians and patients with the following integrated capabilities: 1) quantitative, objective, and comprehensive multi-joint neuromechanical pre-evaluation capabilities aiding multi-joint/DOF diagnosis for individual patients; 2) strenuous and safe passive stretching of hypertonic/deformed arm for loosening up muscles/joints based on the robot-aided diagnosis; 3) (assistive/resistive) active reaching training after passive stretching for regaining/improving motor control ability; and 4) quantitative, objective, and comprehensive neuromechanical outcome evaluation at the level of individual joints/DOFs, multiple joints, and whole arm. Feasibility of the integrated capabilities was demonstrated through experiments with stroke survivors and healthy subjects.

  13. Frequency of abnormal hand and wrist radiographs at time of diagnosis of polyarticular juvenile rheumatoid arthritis.

    PubMed

    Mason, Tom; Reed, Ann M; Nelson, Audrey M; Thomas, Kristen B; Patton, Alice; Hoffman, Alan D; Achenbach, Sara; O'Fallon, William M

    2002-10-01

    To determine the frequency of radiographic abnormalities in hand/wrist radiographs of children with newly diagnosed polyarticular juvenile rheumatoid arthritis (polyJRA) because radiographs of small joints are an important tool in assessing outcomes in RA and there are clinical similarities between RA and polyJRA. A medical record review was performed to identify cases of polyJRA seen at Mayo Clinic from January 1, 1994, to December 31, 2001. Hand/wrist radiographs, obtained at the time of diagnosis, were reviewed by 3 radiologists with attention to periarticular osteopenia, joint space narrowing (JSN), or erosion. At least 2 radiologists had to independently identify abnormal findings on the same radiograph. The relative carpal length (RCL), judged by Poznanski's method, was also determined. From the review of 159 medical records, 60 cases of newly diagnosed polyJRA were identified. Twenty-five of these had hand/wrist radiographs at diagnosis; 18 sets were available for this study. Of those, 2/3 were female, 6% (1/18) had subcutaneous nodules, 7% (1/14) had elevated levels of serum rheumatoid factor, and 44% (7/16) had elevated serum levels of antinuclear antibodies. Median age at diagnosis was 10.2 years, median duration of hand/wrist symptoms at diagnosis was 10 months, and median number of joints with either swelling, pain on range of motion (ROM), or limited ROM was 14.5. Sixty-one percent of radiographs taken at the time of diagnosis of polyJRA were abnormal. While 44% had periarticular osteopenia, 28% had either erosions or JSN. Six (33%) had RCL > 2 SD below the mean for age. Five (83%) of those with RCL, > 2 SD below the mean for age, had periarticular osteopenia, JSN, or erosion. We conclude the frequency of abnormal hand/wrist radiographs is very high very early in the course of polyJRA. More studies are needed to determine to what extent these radiographic abnormalities correlate with clinical outcomes.

  14. High Temporospatial Resolution Dynamic Contrast Enhanced (DCE) Wrist MRI with Variable-Density Pseudo-Random CIRcular Cartesian UnderSampling (CIRCUS) Acquisition: Evaluation of Perfusion in Rheumatoid Arthritis Patients

    PubMed Central

    Liu, Jing; Pedoia, Valentina; Heilmeier, Ursula; Ku, Eric; Su, Favian; Khanna, Sameer; Imboden, John; Graf, Jonathan; Link, Thomas; Li, Xiaojuan

    2016-01-01

    This study is to evaluate highly accelerated 3D dynamic contrast-enhanced (DCE) wrist MRI for assessment of perfusion in rheumatoid arthritis (RA) patients. A pseudo-random variable-density undersampling strategy, CIRcular Cartesian UnderSampling (CIRCUS), was combined with k-t SPARSE-SENSE reconstruction to achieve a highly accelerated 3D DCE wrist MRI. Two healthy volunteers and ten RA patients were studied. Two patients were on methotrexate (MTX) only (Group I) and the other eight were treated with a combination therapy of MTX and Anti-Tumour Necrosis Factor (TNF) therapy (Group II). Patients were scanned at baseline and 3-month follow-up. DCE MR images were used to evaluate perfusion in synovitis and bone marrow edema pattern in the RA wrist joints. A series of perfusion parameters were derived and compared with clinical disease activity scores of 28 joints (DAS28). 3D DCE wrist MR images were obtained with a spatial resolution of 0.3×0.3×1.5mm3 and temporal resolution of 5 s (with an acceleration factor of 20). The derived perfusion parameters, most notably, transition time (dT) of synovitis, showed significant negative correlations with DAS28-ESR (r=-0.80, p<0.05) and DAS28-CRP (r=-0.87, p<0.05) at baseline and also correlated significantly with treatment responses evaluated by clinical score changes between baseline and 3-month follow-up (with DAS28-ESR: r=-0.79, p<0.05, and DAS28-CRP: r=-0.82, p<0.05). Highly accelerated 3D DCE wrist MRI with improved temporospatial resolution has been achieved in RA patients and provides accurate assessment of neovascularization and perfusion in RA joints, showing promise as a potential tool for evaluating treatment responses. PMID:26608949

  15. Arthroscopic partial wrist fusion.

    PubMed

    Ho, Pak-Cheong

    2008-12-01

    The wide intraarticular exposure of the wrist joint under arthroscopic view provides an excellent ground for various forms of partial wrist fusion. Combining with percutaneous fixation technique, arthroscopic partial wrist fusion can potentially generate the best possible functional outcome by preserving the maximal motion pertained with each type of partial wrist fusion because the effect of extraarticular adhesion associated with open surgery can be minimized. From November 1997 to May 2008, the author had performed 12 cases of arthroscopic partial wrist fusion, including scaphotrapeziotrapezoid fusion in 3, scaphoidectomy and 4-corner fusion in 4, radioscapholunate fusion in 3, radiolunate fusion in 1, and lunotriquetral fusion in 1 case. Through the radiocarpal or midcarpal joint, the corresponding articular surfaces were denuded of cartilage using arthroscopic burr and curette. Carpal bones involved in the fusion process were then transfixed with K wires percutaneously after alignment corrected and confirmed under fluoroscopic control. Autogenous cancellous bone graft or bone substitute were inserted and impacted to the fusion site through cannula under direct arthroscopic view. Final fixation could be by multiple K wires or cannulated screw system. Early mobilization was encouraged. Surgical complications were minor, including pin tract infection, skin burn, and delay union in 1 case. Uneventful radiologic union was obtained in 9 cases, stable fibrous union in 2, and nonunion in 1. The average follow-up period was 70 months. Symptom was resolved or improved, and functional motion was gained in all cases. All surgical scars were almost invisible, and aesthetic outcome was excellent.

  16. Triple-phase bone image abnormalities in Lyme arthritis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, S.J.; Dadparvar, S.; Slizofski, W.J.

    1989-10-01

    Arthritis is a frequent manifestation of Lyme disease. Limited triple-phase Tc-99m MDP bone imaging of the wrists and hands with delayed whole-body images was performed in a patient with Lyme arthritis. This demonstrated abnormal joint uptake in the wrists and hands in all three phases, with increased activity seen in other affected joints on delayed whole-body images. These findings are nonspecific and have been previously described in a variety of rheumatologic conditions, but not in Lyme disease. Lyme disease should be considered in the differential diagnosis of articular and periarticular bone scan abnormalities.

  17. Ultrasound Findings on Hands and Wrists of Patients with Systemic Lupus Erythematosus: Relationship with Physical Examination.

    PubMed

    Lins, Carolina Freitas; Lima de Sá Ribeiro, Daniel; Dourado Santos, Willer Gonçalves; Rosa, Genevievi; Machicado, Viviane; Pedreira, Ana Luisa; Pimenta da Fonseca, Emanuela; Mota Duque Sousa, Anna Paula; Rodrigues Silva, Carla Baleeiro; Matos, Marcos Antonio Almeida; Santiago, Mittermayer Barreto

    2017-09-01

    Diagnosis of synovitis/tenosynovitis by physical examination can be difficult. Ultrasound (US) can be an effective tool for the evaluation of joint involvement in systemic lupus erythematosus (SLE). This study will describe musculoskeletal findings by US in SLE patients and the evaluation of their correlation with physical examination. SLE patients underwent clinical/sonographic evaluation of hand/wrists. In total, 896 joints were evaluated: at least 1 change on physical examination was found in 136 joints and at least 1 US abnormality was found in 65 of 896 joints. Out of the 65 joints with US changes, only 13 had findings on physical examination. Conversely, 111 joints had tenderness on physical examination with no sonographic abnormalities. Tenosynovitis was statistically significant more frequently with joint edema (41%) (p = 0.0003). US can detect musculoskeletal changes in only a minority of symptomatic SLE patients. Clinical findings may be related to some reasons that cannot be explained using US. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  18. Ergonomic study on wrist posture when using laparoscopic tools in four different techniques regarding minimally invasive surgery.

    PubMed

    Bartnicka, Joanna; Zietkiewicz, Agnieszka A; Kowalski, Grzegorz J

    2018-03-19

    With reference to four different minimally invasive surgery (MIS) cholecystectomy the aims were: to recognize the factors influencing dominant wrist postures manifested by the surgeon; to detect risk factors involved in maintaining deviated wrist postures; to compare the wrist postures of surgeons while using laparoscopic tools. Video films were recorded during live surgeries. The films were synchronized with wrist joint angles obtained from wireless electrogoniometers placed on the surgeon's hand. The analysis was conducted for five different laparoscopic tools used during all surgical techniques. The most common wrist posture was extension. In the case of one laparoscopic tool, the mean values defining extended wrist posture were distinct in all four surgical techniques. For one type of surgical technique, considered to be the most beneficial for patients, more extreme postures were noticed regarding all laparoscopic tools. We recognized a new factor, apart from the tool's handle design, that influences extreme and deviated wrist postures. It involves three areas of task specification including the type of action, type of motion patterns and motion dynamism. The outcomes proved that the surgical technique which is most beneficial for the patient imposes the greatest strain on the surgeon's wrist.

  19. Wearable Stretch Sensors for Motion Measurement of the Wrist Joint Based on Dielectric Elastomers.

    PubMed

    Huang, Bo; Li, Mingyu; Mei, Tao; McCoul, David; Qin, Shihao; Zhao, Zhanfeng; Zhao, Jianwen

    2017-11-23

    Motion capture of the human body potentially holds great significance for exoskeleton robots, human-computer interaction, sports analysis, rehabilitation research, and many other areas. Dielectric elastomer sensors (DESs) are excellent candidates for wearable human motion capture systems because of their intrinsic characteristics of softness, light weight, and compliance. In this paper, DESs were applied to measure all component motions of the wrist joints. Five sensors were mounted to different positions on the wrist, and each one is for one component motion. To find the best position to mount the sensors, the distribution of the muscles is analyzed. Even so, the component motions and the deformation of the sensors are coupled; therefore, a decoupling method was developed. By the decoupling algorithm, all component motions can be measured with a precision of 5°, which meets the requirements of general motion capture systems.

  20. Remitting Seronegative Symmetrical Synovitis with Pitting Edema Syndrome Caused by Crystal-Induced Arthritis of the Wrist: A Case Report

    PubMed Central

    Hakozaki, Michiyuki; Fukuda, Hironari; Tajino, Takahiro; Kikuchi, Shinichi; Abe, Satoshi; Konno, Shinichi

    2013-01-01

    Objective To describe a rare case of remitting seronegative symmetrical synovitis with pitting edema (RS3PE) syndrome caused by gouty arthritis. Clinical Presentation and Intervention A 76-year-old man presented with swelling and pain in the dorsum of feet and hands bilaterally. From the laboratory and radiologic findings, the diagnosis of gout-induced RS3PE syndrome was made. Conservative therapy with nonsteroidal anti-inflammatory drugs (NSAIDs) and intra-articular corticosteroid injection in the wrist joint completely and rapidly resolved all symptoms. The patient was successfully treated with oral administration of NSAIDs and a one-time intra-articular corticosteroid injection in the left wrist joint. Conclusion This case demonstrated the importance of considering the possibility of crystal-induced arthritis such as gout and pseudogout, as well as malignant disease, when diagnosing the primary disease responsible for RS3PE syndrome. PMID:23006891

  1. Carpal kinematics in quadrupedal monkeys: towards a better understanding of wrist morphology and function

    PubMed Central

    Daver, Guillaume; Berillon, Gilles; Grimaud-Hervé, Dominique

    2012-01-01

    The purpose of this study is to provide new data on carpal kinematics in primates in order to deepen our understanding of the relationships between wrist morphology and function. To that end, we provide preliminary data on carpal kinematics in seven species of quadrupedal monkeys that have not been previously investigated in this regard (cercopithecoids, n = 4; ceboids, n = 3). We radiographed wrists from cadavers at their maximum radial and ulnar deviations, as well as at maximum flexion and extension. We took angular measurements to quantify the contribution of the mobility of the two main wrist joints (antebrachiocarpal and midcarpal) with respect to total wrist mobility. We also recorded qualitative observations. Our quantitative results show few clear differences among quadrupedal monkeys for radioulnar deviation and flexion–extension: all the primates studied exhibit a greater midcarpal mobility (approximately 54–83% of the total range of motion) than antebrachiocarpal mobility; however, we identified two patterns of carpal kinematics that show the functional impact of previously recognised morphological variations in quadrupedal monkeys. Firstly, qualitative results show that the partition that divides the proximal joint of the wrist in ceboids results in less mobility and more stability of the ulnar part of the wrist than is seen in cercopithecoids. Secondly, we show that the olive baboon specimen (Papio anubis) is characterised by limited antebrachiocarpal mobility for extension; this effect is likely the result of a radial process that projects on the scaphoid notch, as well as an intraarticular meniscus. Because of these close relationships between carpal kinematics and morphology in quadrupedal monkeys, we hypothesise that, to some extent, these functional tendencies are related to their locomotor hand postures. PMID:22050662

  2. Combined functional electrical stimulation (FES) and robotic system for wrist rehabiliation after stroke.

    PubMed

    Hu, Xiaoling; Tong, K Y; Li, R; Chen, M; Xue, J J; Ho, S K; Chen, P N

    2010-01-01

    Functional electrical stimulation (FES) and rehabilitation robots are techniques used to assist in post-stroke rehabilitation. However, FES and rehabilitation robots are still separate systems currently; and their combined training effects on persons after experiencing a stroke have not been well studied yet. In this work, a new combined FES-robot system driven by user's voluntary intention was developed for wrist joint training after stroke. The performance of the FES-robot assisted wrist tracking was evaluated on five subjects with chronic stroke. With simultaneous assistance from both the FES and robot parts of the system, the motion accuracy was improved and excessive activation in elbow flexor was reduced during wrist tracking.

  3. Joint Replacement (Finger and Wrist Joints)

    MedlinePlus

    ... Lawnmower Safety Snowblower safety Pumpkin Carving Gardening Safety Turkey Carving Removing a Ring Fireworks Safety Español Artritis ... Lawnmower Safety Snowblower safety Pumpkin Carving Gardening Safety Turkey Carving Removing a Ring Fireworks Safety Español Artritis ...

  4. KSC-05pd2463

    NASA Image and Video Library

    2005-11-07

    KENNEDY SPACE CENTER, FLA. - In the Orbiter Processing Facility Bay 1 at NASA Kennedy Space Center, a crane is lowered toward the remote manipulator system boom in Atlantis’ payload bay. The boom is being removed from Atlantis and will be temporarily stored. The RMS includes the electromechanical arm that maneuvers a payload from the payload bay of the orbiter to its deployment position and then releases it. It can also grapple a free-flying payload, maneuver it to the payload bay of the orbiter and berth it in the orbiter. The RMS arm is 50 feet 3 inches long and 15 inches in diameter. It weighs 905 pounds, and the total system weighs 994 pounds. The RMS has six joints that correspond roughly to the joints of the human arm, with shoulder yaw and pitch joints; an elbow pitch joint; and wrist pitch, yaw and roll joints. The end effector is the unit at the end of the wrist that actually grabs, or grapples, the payload.

  5. KSC-05pd2465

    NASA Image and Video Library

    2005-11-07

    KENNEDY SPACE CENTER, FLA. - In the Orbiter Processing Facility Bay 1 at NASA Kennedy Space Center, workers secure a crane to the remote manipulator system boom in Atlantis’ payload bay. The boom is being removed from Atlantis and will be temporarily stored.. The RMS includes the electromechanical arm that maneuvers a payload from the payload bay of the orbiter to its deployment position and then releases it. It can also grapple a free-flying payload, maneuver it to the payload bay of the orbiter and berth it in the orbiter. The RMS arm is 50 feet 3 inches long and 15 inches in diameter. It weighs 905 pounds, and the total system weighs 994 pounds. The RMS has six joints that correspond roughly to the joints of the human arm, with shoulder yaw and pitch joints; an elbow pitch joint; and wrist pitch, yaw and roll joints. The end effector is the unit at the end of the wrist that actually grabs, or grapples, the payload.

  6. KSC-05pd2468

    NASA Image and Video Library

    2005-11-07

    KENNEDY SPACE CENTER, FLA. - In the Orbiter Processing Facility Bay 1 at NASA Kennedy Space Center, the remote manipulator system boom that was removed from Atlantis’ payload bay is lifted out of the way. The boom will be temporarily stored. The RMS includes the electromechanical arm that maneuvers a payload from the payload bay of the orbiter to its deployment position and then releases it. It can also grapple a free-flying payload, maneuver it to the payload bay of the orbiter and berth it in the orbiter. The RMS arm is 50 feet 3 inches long and 15 inches in diameter. It weighs 905 pounds, and the total system weighs 994 pounds. The RMS has six joints that correspond roughly to the joints of the human arm, with shoulder yaw and pitch joints; an elbow pitch joint; and wrist pitch, yaw and roll joints. The end effector is the unit at the end of the wrist that actually grabs, or grapples, the payload.

  7. KSC-05pd2464

    NASA Image and Video Library

    2005-11-07

    KENNEDY SPACE CENTER, FLA. -In the Orbiter Processing Facility Bay 1 at NASA Kennedy Space Center, a crane is attached to the remote manipulator system boom in Atlantis’ payload bay. The boom is being removed from Atlantis and will be temporarily stored. The RMS includes the electromechanical arm that maneuvers a payload from the payload bay of the orbiter to its deployment position and then releases it. It can also grapple a free-flying payload, maneuver it to the payload bay of the orbiter and berth it in the orbiter. The RMS arm is 50 feet 3 inches long and 15 inches in diameter. It weighs 905 pounds, and the total system weighs 994 pounds. The RMS has six joints that correspond roughly to the joints of the human arm, with shoulder yaw and pitch joints; an elbow pitch joint; and wrist pitch, yaw and roll joints. The end effector is the unit at the end of the wrist that actually grabs, or grapples, the payload.

  8. Postural and Intention Tremors: A Detailed Clinical Study of Essential Tremor vs. Parkinson’s Disease

    PubMed Central

    Sternberg, Eliezer J.; Alcalay, Roy N.; Levy, Oren A.; Louis, Elan D.

    2013-01-01

    Background: An estimated 30–50% of essential tremor (ET) diagnoses are incorrect, and the true diagnosis in those patients is often Parkinson’s disease (PD) or other tremor disorders. There are general statements about the tremor in these ET and PD, but published data on the more subtle characteristics of tremor are surprisingly limited. Postural tremor may occur in both disorders, adding to the difficulty. There are several anecdotal impressions regarding specific features of postural tremor in ET vs. PD, including joint distribution (e.g., phalanges, metacarpal-phalangeal joints, wrist), tremor directionality (e.g., flexion-extension vs. pronation-supination), and presence of intention tremor. However, there is little data to support these impressions. Methods: In this cross-sectional study, 100 patients (ET, 50 PD) underwent detailed videotaped neurological examinations. Arm tremor was rated by a movement disorder neurologist who assessed severity and directionality across multiple joints. Results: During sustained arm extension, ET patients exhibited more wrist than metacarpal-phalangeal and phalangeal joint tremor than did PD patients (p < 0.001), and more wrist flexion-extension tremor than wrist pronation-supination tremor (p < 0.001). During the finger-nose-finger maneuver, intention tremor was present in approximately one in four (28%) ET patients vs. virtually none (4%) of the Parkinson’s patients (p < 0.001). Conclusions: We evaluated the location, severity, and directionality of postural tremor in ET and PD, and the presence of intention tremor, observing several clinical differences. We hope that detailed phenomenological data on tremor in ET and PD will help practicing physicians delineate the two diseases. PMID:23717300

  9. Plasticity in cortical motor upper-limb representation following stroke and rehabilitation: two longitudinal multi-joint FMRI case-studies.

    PubMed

    Stark, A; Meiner, Z; Lefkovitz, R; Levin, N

    2012-04-01

    Motor dysfunction and recovery following stroke and rehabilitation are associated with primary motor cortex plasticity. To better track these effects we studied two patients with sub-acute sub-cortical stroke causing hemiparesis, who underwent an effective behavioral treatment termed Constraint Induced Movement Therapy (CIMT). The therapy involves 2 weeks of intensive motor training of the hemiparetic limb coupled with immobilization of the unaffected limb. The study included a longitudinal series of clinical evaluations and fMRI scans, before and after the treatment. The fMRI task included wrist, elbow, or ankle movements. Activity in the M1 upper-limb region of control subjects was stable, strictly contralateral, and similar in amplitude for elbow and wrist movements. These findings reflect the well-known contralateral motor control and support the idea of overlapping representations of adjacent joints in M1. In both patients, pre-CIMT activation patterns in M1 were tested twice and did not change significantly, were contralateral, and included elbow-wrist differences. Following CIMT, the clinical condition of both patients improved and three fMRI-explored prototypes were found: First, cluster position remained constant; Second, ipsilateral activity appeared in the unaffected hemispheres during hemiparetic movements; Third, patient-specific elbow-wrist inter and intra hemispheric differences were modified. All effects were long-lasting. We suggest that overlapping representations of adjacent joints contributed to the cortical plasticity observed following CIMT. Our findings should be confirmed by studying larger groups of homogeneous patients. Nevertheless, this study introduces multi-joint imaging studies and shows that it is both possible and valuable to carry it out in stroke patients.

  10. Near-infrared Fluorescence Optical Imaging in Early Rheumatoid Arthritis: A Comparison to Magnetic Resonance Imaging and Ultrasonography.

    PubMed

    Krohn, Michaela; Ohrndorf, Sarah; Werner, Stephanie G; Schicke, Bernd; Burmester, Gerd-Rüdiger; Hamm, Bernd; Backhaus, Marina; Hermann, Kay-Geert A

    2015-07-01

    Near-infrared fluorescence optical imaging (FOI) is a novel imaging technology in the detection and evaluation of different arthritides. FOI was validated in comparison to magnetic resonance imaging (MRI), greyscale ultrasonography (GSUS), and power Doppler ultrasonography (PDUS) in patients with early rheumatoid arthritis (RA). Hands of 31 patients with early RA were examined by FOI, MRI, and US. In each modality, synovitis of the wrist, metacarpophalangeal joints (MCP) 2-5, and proximal interphalangeal joints (PIP) 2-5 were scored on a 4-point scale (0-3). Sensitivity and specificity of FOI were analyzed in comparison to MRI and US as reference methods, differentiating between 3 phases of FOI enhancement (P1-3). Intraclass correlation coefficients (ICC) were calculated to evaluate the agreement of FOI with MRI and US. A total of 279 joints (31 wrists, 124 MCP and 124 PIP joints) were evaluated. With MRI as the reference method, overall sensitivity/specificity of FOI was 0.81/0.00, 0.49/0.84, and 0.86/0.38 for wrist, MCP, and PIP joints, respectively. Under application of PDUS as reference, sensitivity was even higher, while specificity turned out to be low, except for MCP joints (0.88/0.15, 0.81/0.76, and 1.00/0.27, respectively). P2 appears to be the most sensitive FOI phase, while P1 showed the highest specificity. The best agreement of FOI was shown for PDUS, especially with regard to MCP and PIP joints (ICC of 0.57 and 0.53, respectively), while correlation with MRI was slightly lower. FOI remains an interesting diagnostic tool for patients with early RA, although this study revealed limitations concerning the detection of synovitis. Further research is needed to evaluate its full diagnostic potential in rheumatic diseases.

  11. Effects of the racket polar moment of inertia on dominant upper limb joint moments during tennis serve.

    PubMed

    Rogowski, Isabelle; Creveaux, Thomas; Chèze, Laurence; Macé, Pierre; Dumas, Raphaël

    2014-01-01

    This study examined the effect of the polar moment of inertia of a tennis racket on upper limb loading in the serve. Eight amateur competition tennis players performed two sets of 10 serves using two rackets identical in mass, position of center of mass and moments of inertia other than the polar moment of inertia (0.00152 vs 0.00197 kg.m2). An eight-camera motion analysis system collected the 3D trajectories of 16 markers, located on the thorax, upper limbs and racket, from which shoulder, elbow and wrist net joint moments and powers were computed using inverse dynamics. During the cocking phase, increased racket polar moment of inertia was associated with significant increases in the peak shoulder extension and abduction moments, as well the peak elbow extension, valgus and supination moments. During the forward swing phase, peak wrist extension and radial deviation moments significantly increased with polar moment of inertia. During the follow-through phase, the peak shoulder adduction, elbow pronation and wrist external rotation moments displayed a significant inverse relationship with polar moment of inertia. During the forward swing, the magnitudes of negative joint power at the elbow and wrist were significantly larger when players served using the racket with a higher polar moment of inertia. Although a larger polar of inertia allows players to better tolerate off-center impacts, it also appears to place additional loads on the upper extremity when serving and may therefore increase injury risk in tennis players.

  12. Characteristics of upper extremity's muscle strength in Turkish national wheelchair basketball players team.

    PubMed

    Akınoğlu, Bihter; Kocahan, Tuğba

    2017-02-01

    The objective of this study was to reveal characteristics of muscle strength of upper extremities of wheelchair (WC) basketball players and to ensure more-specific training program preparation. Isokinetic muscle strength of 12 WC basketball players were assessed by ISOMED 2000 device. The assessment protocol was evaluated at 60°/sec velocity with 5 times repeated force and at 240°/sec with 15 times repeated force. This protocol was carried out individually for shoulder flexion-extension and wrist flexion-extension movements at the right and left extremities. The flexion/extension ratio was determined to be outside of the ratios accepted as normal for primarily shoulder joint and for wrist joint. The extension movement was stronger than flexion movement in the shoulders at both velocities and the flexion movement was stronger than ex-tension movement in the wrist. The repeat times where the peak torque occurred were 2-3 repeats at 60°/sec velocity during flexion and extension movements for the wrist and shoulders, and the peak torque occurred at an average of 5-6 repeats in the shoulders at 240°/sec velocity and it occurred at 3-4 repeats in the wrist. The angles where the peak torque of the shoulder flexion and extension occurred varied between 80°-115° at both velocities, and it varied between 5°-30° angles for the wrist. As this study revealed, determination of muscle strength characteristics of WC athletes and especially using objective isokinetic devices will guide the planning of the appropriate training and exercise programs and preventing sports injuries in long term.

  13. The Sequence of Hip and Selected Upper-Extremity Joint Movements During the Golf Drive.

    ERIC Educational Resources Information Center

    Hunter, Charles L.

    This study analyzed wrist, elbow, and hip actions of golfers who were accurately driving a golf ball a maximum distance. Electrogoniometry and cinematography were used to measure wrist, forearm, elbow, and hip actions during the downswing of 10 low-handicap golfers who were attempting to drive a minimum of 225 yards within a 50-yard corridor.…

  14. RHEUMATOID ARTHRITIS. PHYSICAL MEASURES IN TREATMENT OF CHILDREN.

    PubMed

    EISING, L M; SOULES, B

    1964-05-01

    Prognosis in rheumatic arthritis in children is good, provided total care is given, deformity prevented and function maintained. Bed rest is desirable until active inflammation of the joints has subsided. During convalescence a balance between rest and exercise must be maintained to avoid recurrence of inflammation of the joints. When there is progressive deformity or disabling pain in the wrist, a molded leather wrist-cuff splint can control the deformity, decrease or abolish pain and lessen swelling. If there is valgus deformity of the knee or external rotation of the tibia, with no more than ten degrees of knee flexion deformity, correction can be obtained by simple manipulations.

  15. Isolated scaphotrapeziotrapezoid osteoarthritis treatment using resurfacing arthroplasty with scaphoid anchorage.

    PubMed

    Humada Álvarez, G; Simón Pérez, C; García Medrano, B; Faour Martín, O; Marcos Rodríguez, J J; Vega Castrillo, A; Martín Ferrero, M A

    The aim of this study is to show the results of scaphotrapeziotrapezoid (STT) joint osteoarthritis treatment performing resurfacing arthroplasty with scaphoid anchorage. An observational, descriptive and retrospective study was performed. Ten patients with isolated STT joint osteoarthritis were studied between 2013 and 2015. The mean follow-up time was 26months. Clinical results, functional and subjective scores were reviewed. The patients were satisfied, achieving an average of 2.1 (0-3) on the VAS score and 16 (2 to 28) in the DASH questionnaire, and returning to work in the first three months post-surgery. Recovery of range of motion compared to the contralateral wrist was 96% in extension, 95% in flexion, 87% in ulnar deviation and 91% in radial deviation. The average handgrip strength of the wrist was 95% and pinch strength was 95% compared to the contralateral side. There were no intraoperative complications or alterations in postoperative carpal alignment. Resurfacing arthroplasty is proposed as a good and novel alternative in treating isolated SST joint arthritis. Achieving the correct balance between the strength and mobility of the wrist, without causing carpal destabilisation, is important to obtain satisfactory clinical and functional results. Copyright © 2017. Publicado por Elsevier España, S.L.U.

  16. A novel 4-DOF surgical instrument with modular joints and 6-Axis Force sensing capability.

    PubMed

    Li, Kun; Pan, Bo; Zhang, Fuhai; Gao, Wenpeng; Fu, Yili; Wang, Shuguo

    2017-03-01

    It is difficult for surgeons to exert appropriate forces during delicate operations due to lack of force feedback in robot-assisted minimally invasive surgery (RMIS). A 4-DOF surgical grasper with a modular wrist and 6-axis force sensing capability is developed. A grasper integrated with a miniature force and torque sensor based on the Stewart platform is designed, and a cable tension decomposition mechanism is designed to alleviate influence of the cable tension to the sensor. A modularized wrist consisting of four joint units is designed to facilitate integration of the sensor and eliminate coupled motion of the wrist. Sensing ranges of this instrument are ±10 N and ±160 N mm, and resolutions are 1.2% in radial directions, 5% in axial direction, and 4.2% in rotational directions. An ex vivo experiment shows that this instrument prototype successfully measures the interaction forces. A 4-DOF surgical instrument with modular joints and 6-axis force sensing capability is developed. This instrument can be used for force feedback in RMIS. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  17. Wrist Arthrodesis for Failed Total Wrist Arthroplasty.

    PubMed

    Adams, Brian D; Kleinhenz, Ben P; Guan, Justin J

    2016-06-01

    Treatment options for failed total wrist arthroplasty include implant revision, resection arthroplasty, and arthrodesis. Variable results associated with different techniques have been reported for arthrodesis and the procedure has substantial technical challenges, including restoration of wrist height, obtaining stable fixation, and achieving bony fusion. This study evaluates the radiographic results of a surgical technique for conversion of a failed arthroplasty to an arthrodesis. A retrospective chart and radiograph review was performed in 20 wrists in 18 patients in whom conversion to an arthrodesis was performed using a contoured cancellous femoral head structural allograft and a wrist arthrodesis plate. Supplemental demineralized bone matrix combined with corticocancellous allograft chips was also used in 15 wrists. Median age at arthrodesis was 61 years (range, 45-78 years), and median follow-up was 34 months (range, 4-71 months). Nineteen of 20 wrists fused following the index procedure at a median of 4 months (range, 3-7 months). Proximal plate loosening occurred in 1 wrist but the joint still fused at 6 months; a successful osteotomy and revision of screw fixation was done 2 years later to correct the deformity and hardware irritation in this case. Complications were otherwise limited to 1 superficial infection that resolved with intravenous antibiotics. This technique for conversion of a failed total wrist arthroplasty to a wrist arthrodesis is safe, effective, and versatile. Wrist deformity is corrected, wrist height can be restored, stable fixation is obtained, and a high rate of fusion is achieved despite filling large defects using structural cancellous allograft. Therapeutic IV. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  18. An 8-DOF dual-arm system for advanced teleoperation performance experiments

    NASA Technical Reports Server (NTRS)

    Bejczy, Antal K.; Szakaly, Zoltan F.

    1992-01-01

    This paper describes the electro-mechanical and control features of an 8-DOF manipulator manufactured by AAI Corporation and installed at the Jet Propulsion Lab. (JPL) in a dual-arm setting. The 8-DOF arm incorporates a variety of features not found in other lab or industrial manipulators. Some of the unique features are: 8-DOF revolute configuration with no lateral offsets at joint axes; 1 to 5 payload to weight ratio with 20 kg (44 lb) payload at a 1.75 m (68.5 in.) reach; joint position measurement with dual relative encoders and potentiometer; infinite roll of joint 8 with electrical and fiber optic slip rings; internal fiber optic link of 'smart' end effectors; four-axis wrist; graphite epoxy links; high link and joint stiffness; use of an upgraded JPL Universal Motor Controller (UMC) capable of driving up to 16 joints. The 8-DOF arm is equipped with a 'smart' end effector which incorporates a 6-DOF forcemoment sensor at the end effector base and grasp force sensors at the base of the parallel jaws. The 8-DOF arm is interfaced to a 6 DOF force reflecting hand controller. The same system is duplicated for and installed at NASA-Langley.

  19. Characterization of a Robotic Manipulator for Dynamic Wind Tunnel Applications

    DTIC Science & Technology

    2015-03-26

    further enhancements would need to be performed individually for each joint. This research effort focused on the improvement of the MTA wrist roll ...Measurement Unit ( IMU ), was used to validate the Euler angle output calculated by the MTA Computer using forward kinematics. Additionally, fast-response...61 3.7 Modeling the Wrist Roll Motor and Controller . . . . . . . . . . . . . . . . . . . . . 64 3.8 Proportional Control for Improved Performance

  20. Arthroscopic assisted tendon reconstruction for triangular fibrocartilage complex irreparable tears.

    PubMed

    Luchetti, R; Atzei, A

    2017-05-01

    We report our 11-year experience of performing arthroscopically assisted triangular fibrocartilage complex reconstruction in the treatment of chronic distal radio-ulnar joint instability resulting from irreparable triangular fibrocartilage complex injuries. Eleven patients were treated. Three skin incisions were made in order to create radial and ulna tunnels for passage of the tendon graft, which is used to reconstruct the dorsal and palmar radio-ulnar ligaments, under fluoroscopic and arthroscopic guidance. At a mean follow-up of 68 months all but one had a stable distal radio-ulnar joint. Pain and grip strength, Mayo wrist score, Disability of the Arm Hand and Shoulder and patient-rated wrist and hand evaluation scores improved. The ranges of forearm rotation remained largely unchanged. Complications included an early tendon graft tear, two late-onset graft ruptures, one ulna styloid fracture during surgery and persistent wrist discomfort during forearm rotation requiring tendon graft revision in one case. An arthroscopic assisted approach for triangular fibrocartilage complex reconstruction appears safe and produces comparable results with the open technique. IV.

  1. Carpal tunnel volume changes of the wrist under distraction.

    PubMed

    Cho, M S; Means, K R; Shrout, J A; Segalman, K A

    2008-10-01

    This study attempts to determine changes in carpal canal volume with distraction across the wrist. Uniform longitudinal distraction was maintained with two external fixators on the radial and ulnar aspects of the forearm axis of five cadaver specimens. After CT scanning, volume determinations were made at 5 mm increments beginning at the lunocapitate joint to a point 1.5 cm distal to the middle finger carpometacarpal joint. There was a statistically significant decrease of the mean total carpal canal volume from 0 to 4.54 kg of distraction, with no statistically significant decrease from 0 to 2.27 kg or 2.27 to 4.54 kg. The largest decrease occurred at 15 and 20 mm distal to the proximal edge of the transverse carpal ligament corresponding to the level of the hamate hook. Reduction in mean carpal canal volume was 10.2% and 7.5% at these distances, respectively, from 0 to 4.54 kg of distraction. Progressive distraction across the wrist causes a decrease in total carpal canal volume.

  2. Effect of wrist and interphalangeal thumb movement on zone T2 flexor pollicis longus tendon tension in a human cadaver model.

    PubMed

    Rappaport, Patricia O; Thoreson, Andrew R; Yang, Tai-Hua; Reisdorf, Ramona L; Rappaport, Stephen M; An, Kai-Nan; Amadio, Peter C

    2015-01-01

    Therapy after flexor pollicis longus (FPL) repair typically mimics finger flexor management, but this ignores anatomic and biomechanical features unique to the FPL. We measured FPL tendon tension in zone T2 to identify biomechanically appropriate exercises for mobilizing the FPL. Eight human cadaver hands were studied to identify motions that generated enough force to achieve FPL movement without exceeding hypothetical suture strength. With the carpometacarpal and metacarpophalangeal joints blocked, appropriate forces were produced for both passive interphalangeal (IP) motion with 30° wrist extension and simulated active IP flexion from 0° to 35° with the wrist in the neutral position. This work provides a biomechanical basis for safely and effectively mobilizing the zone T2 FPL tendon. Our cadaver study suggests that it is safe and effective to perform early passive and active exercise to an isolated IP joint. NA. Copyright © 2015 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  3. Robot-Assisted Proprioceptive Training with Added Vibro-Tactile Feedback Enhances Somatosensory and Motor Performance.

    PubMed

    Cuppone, Anna Vera; Squeri, Valentina; Semprini, Marianna; Masia, Lorenzo; Konczak, Jürgen

    2016-01-01

    This study examined the trainability of the proprioceptive sense and explored the relationship between proprioception and motor learning. With vision blocked, human learners had to perform goal-directed wrist movements relying solely on proprioceptive/haptic cues to reach several haptically specified targets. One group received additional somatosensory movement error feedback in form of vibro-tactile cues applied to the skin of the forearm. We used a haptic robotic device for the wrist and implemented a 3-day training regimen that required learners to make spatially precise goal-directed wrist reaching movements without vision. We assessed whether training improved the acuity of the wrist joint position sense. In addition, we checked if sensory learning generalized to the motor domain and improved spatial precision of wrist tracking movements that were not trained. The main findings of the study are: First, proprioceptive acuity of the wrist joint position sense improved after training for the group that received the combined proprioceptive/haptic and vibro-tactile feedback (VTF). Second, training had no impact on the spatial accuracy of the untrained tracking task. However, learners who had received VTF significantly reduced their reliance on haptic guidance feedback when performing the untrained motor task. That is, concurrent VTF was highly salient movement feedback and obviated the need for haptic feedback. Third, VTF can be also provided by the limb not involved in the task. Learners who received VTF to the contralateral limb equally benefitted. In conclusion, somatosensory training can significantly enhance proprioceptive acuity within days when learning is coupled with vibro-tactile sensory cues that provide feedback about movement errors. The observable sensory improvements in proprioception facilitates motor learning and such learning may generalize to the sensorimotor control of the untrained motor tasks. The implications of these findings for neurorehabilitation are discussed.

  4. Early rheumatoid disease. II. Patterns of joint involvement.

    PubMed Central

    Fleming, A; Benn, R T; Corbett, M; Wood, P H

    1976-01-01

    Data from the first research clinic visit (Fleming and others, 1976) have been subjected to factor analysis to identify early patterns of joint involvement. Nine patterns emerged. Two patterns, if present early, were found to have prognostic significance. An eventually more severe disease was associated with a pattern of large joint involvement (shoulder, elbow, wrist, knee) and a pattern based on metatarsophalangeal joints I and III. PMID:970995

  5. Kinematic equations for control of the redundant eight-degree-of-freedom advanced research manipulator 2

    NASA Technical Reports Server (NTRS)

    Williams, Robert L., II

    1992-01-01

    The forward position and velocity kinematics for the redundant eight-degree-of-freedom Advanced Research Manipulator 2 (ARM2) are presented. Inverse position and velocity kinematic solutions are also presented. The approach in this paper is to specify two of the unknowns and solve for the remaining six unknowns. Two unknowns can be specified with two restrictions. First, the elbow joint angle and rate cannot be specified because they are known from the end-effector position and velocity. Second, one unknown must be specified from the four-jointed wrist, and the second from joints that translate the wrist, elbow joint excluded. There are eight solutions to the inverse position problem. The inverse velocity solution is unique, assuming the Jacobian matrix is not singular. A discussion of singularities is based on specifying two joint rates and analyzing the reduced Jacobian matrix. When this matrix is singular, the generalized inverse may be used as an alternate solution. Computer simulations were developed to verify the equations. Examples demonstrate agreement between forward and inverse solutions.

  6. Advanced servo manipulator

    DOEpatents

    Holt, W.E.; Kuban, D.P.; Martin, H.L.

    1988-10-25

    An advanced servo manipulator has modular parts. Modular motor members drive individual input gears to control shoulder roll, shoulder pitch, elbow pitch, wrist yaw, wrist pitch, wrist roll, and tong spacing. The modules include a support member, a shoulder module for controlling shoulder roll, and a sleeve module attached to the shoulder module in fixed relation thereto. The shoulder roll sleeve module has an inner cylindrical member rotatable relative to the outer cylindrical member, and upon which a gear pod assembly is mounted. A plurality of shafts are driven by the gears, which are in turn driven by individual motor modules to transmit rotary power to control elbow pitch as well as to provide four different rotary shafts across the bendable elbow joint to supply rotary motive power to a wrist member and tong member. 41 figs.

  7. Advanced servo manipulator

    DOEpatents

    Holt, William E.; Kuban, Daniel P.; Martin, H. Lee

    1988-01-01

    An advanced servo manipulator has modular parts. Modular motor members drive individual input gears to control shoulder roll, shoulder pitch, elbow pitch, wrist yaw, wrist pitch, wrist roll, and tong spacing. The modules include a support member, a shoulder module for controlling shoulder roll, and a sleeve module attached to the shoulder module in fixed relation thereto. The shoulder roll sleeve module has an inner cylindrical member rotatable relative to the outer cylindrical member, and upon which a gear pod assembly is mounted. A plurality of shafts are driven by the gears, which are in turn driven by individual motor modules to transmit rotary power to control elbow pitch as well as to provide four different rotary shafts across the bendable elbow joint to supply rotary motive power to a wrist member and tong member.

  8. Effects of the Racket Polar Moment of Inertia on Dominant Upper Limb Joint Moments during Tennis Serve

    PubMed Central

    Rogowski, Isabelle; Creveaux, Thomas; Chèze, Laurence; Macé, Pierre; Dumas, Raphaël

    2014-01-01

    This study examined the effect of the polar moment of inertia of a tennis racket on upper limb loading in the serve. Eight amateur competition tennis players performed two sets of 10 serves using two rackets identical in mass, position of center of mass and moments of inertia other than the polar moment of inertia (0.00152 vs 0.00197 kg.m2). An eight-camera motion analysis system collected the 3D trajectories of 16 markers, located on the thorax, upper limbs and racket, from which shoulder, elbow and wrist net joint moments and powers were computed using inverse dynamics. During the cocking phase, increased racket polar moment of inertia was associated with significant increases in the peak shoulder extension and abduction moments, as well the peak elbow extension, valgus and supination moments. During the forward swing phase, peak wrist extension and radial deviation moments significantly increased with polar moment of inertia. During the follow-through phase, the peak shoulder adduction, elbow pronation and wrist external rotation moments displayed a significant inverse relationship with polar moment of inertia. During the forward swing, the magnitudes of negative joint power at the elbow and wrist were significantly larger when players served using the racket with a higher polar moment of inertia. Although a larger polar of inertia allows players to better tolerate off-center impacts, it also appears to place additional loads on the upper extremity when serving and may therefore increase injury risk in tennis players. PMID:25117871

  9. Presence and Absence of Muscle Contraction Elicited by Peripheral Nerve Electrical Stimulation Differentially Modulate Primary Motor Cortex Excitability.

    PubMed

    Sasaki, Ryoki; Kotan, Shinichi; Nakagawa, Masaki; Miyaguchi, Shota; Kojima, Sho; Saito, Kei; Inukai, Yasuto; Onishi, Hideaki

    2017-01-01

    Modulation of cortical excitability by sensory inputs is a critical component of sensorimotor integration. Sensory afferents, including muscle and joint afferents, to somatosensory cortex (S1) modulate primary motor cortex (M1) excitability, but the effects of muscle and joint afferents specifically activated by muscle contraction are unknown. We compared motor evoked potentials (MEPs) following median nerve stimulation (MNS) above and below the contraction threshold based on the persistence of M-waves. Peripheral nerve electrical stimulation (PES) conditions, including right MNS at the wrist at 110% motor threshold (MT; 110% MNS condition), right MNS at the index finger (sensory digit nerve stimulation [DNS]) with stimulus intensity approximately 110% MNS (DNS condition), and right MNS at the wrist at 90% MT (90% MNS condition) were applied. PES was administered in a 4 s ON and 6 s OFF cycle for 20 min at 30 Hz. In Experiment 1 ( n = 15), MEPs were recorded from the right abductor pollicis brevis (APB) before (baseline) and after PES. In Experiment 2 ( n = 15), M- and F-waves were recorded from the right APB. Stimulation at 110% MNS at the wrist evoking muscle contraction increased MEP amplitudes after PES compared with those at baseline, whereas DNS at the index finger and 90% MNS at the wrist not evoking muscle contraction decreased MEP amplitudes after PES. M- and F-waves, which reflect spinal cord or muscular and neuromuscular junctions, did not change following PES. These results suggest that muscle contraction and concomitant muscle/joint afferent inputs specifically enhance M1 excitability.

  10. Presence and Absence of Muscle Contraction Elicited by Peripheral Nerve Electrical Stimulation Differentially Modulate Primary Motor Cortex Excitability

    PubMed Central

    Sasaki, Ryoki; Kotan, Shinichi; Nakagawa, Masaki; Miyaguchi, Shota; Kojima, Sho; Saito, Kei; Inukai, Yasuto; Onishi, Hideaki

    2017-01-01

    Modulation of cortical excitability by sensory inputs is a critical component of sensorimotor integration. Sensory afferents, including muscle and joint afferents, to somatosensory cortex (S1) modulate primary motor cortex (M1) excitability, but the effects of muscle and joint afferents specifically activated by muscle contraction are unknown. We compared motor evoked potentials (MEPs) following median nerve stimulation (MNS) above and below the contraction threshold based on the persistence of M-waves. Peripheral nerve electrical stimulation (PES) conditions, including right MNS at the wrist at 110% motor threshold (MT; 110% MNS condition), right MNS at the index finger (sensory digit nerve stimulation [DNS]) with stimulus intensity approximately 110% MNS (DNS condition), and right MNS at the wrist at 90% MT (90% MNS condition) were applied. PES was administered in a 4 s ON and 6 s OFF cycle for 20 min at 30 Hz. In Experiment 1 (n = 15), MEPs were recorded from the right abductor pollicis brevis (APB) before (baseline) and after PES. In Experiment 2 (n = 15), M- and F-waves were recorded from the right APB. Stimulation at 110% MNS at the wrist evoking muscle contraction increased MEP amplitudes after PES compared with those at baseline, whereas DNS at the index finger and 90% MNS at the wrist not evoking muscle contraction decreased MEP amplitudes after PES. M- and F-waves, which reflect spinal cord or muscular and neuromuscular junctions, did not change following PES. These results suggest that muscle contraction and concomitant muscle/joint afferent inputs specifically enhance M1 excitability. PMID:28392766

  11. A comparative analysis of speed profile models for wrist pointing movements.

    PubMed

    Vaisman, Lev; Dipietro, Laura; Krebs, Hermano Igo

    2013-09-01

    Following two decades of design and clinical research on robot-mediated therapy for the shoulder and elbow, therapeutic robotic devices for other joints are being proposed: several research groups including ours have designed robots for the wrist, either to be used as stand-alone devices or in conjunction with shoulder and elbow devices. However, in contrast with robots for the shoulder and elbow which were able to take advantage of descriptive kinematic models developed in neuroscience for the past 30 years, design of wrist robots controllers cannot rely on similar prior art: wrist movement kinematics has been largely unexplored. This study aimed at examining speed profiles of fast, visually evoked, visually guided, target-directed human wrist pointing movements. One thousand three-hundred ninety-eight (1398) trials were recorded from seven unimpaired subjects who performed center-out flexion/extension and abduction/adduction wrist movements and fitted with 19 models previously proposed for describing reaching speed profiles. A nonlinear, least squares optimization procedure extracted parameters' sets that minimized error between experimental and reconstructed data. Models' performances were compared based on their ability to reconstruct experimental data. Results suggest that the support-bounded lognormal is the best model for speed profiles of fast, wrist pointing movements. Applications include design of control algorithms for therapeutic wrist robots and quantitative metrics of motor recovery.

  12. A cable-driven wrist robotic rehabilitator using a novel torque-field controller for human motion training.

    PubMed

    Chen, Weihai; Cui, Xiang; Zhang, Jianbin; Wang, Jianhua

    2015-06-01

    Rehabilitation technologies have great potentials in assisted motion training for stroke patients. Considering that wrist motion plays an important role in arm dexterous manipulation of activities of daily living, this paper focuses on developing a cable-driven wrist robotic rehabilitator (CDWRR) for motion training or assistance to subjects with motor disabilities. The CDWRR utilizes the wrist skeletal joints and arm segments as the supporting structure and takes advantage of cable-driven parallel design to build the system, which brings the properties of flexibility, low-cost, and low-weight. The controller of the CDWRR is designed typically based on a virtual torque-field, which is to plan "assist-as-needed" torques for the spherical motion of wrist responding to the orientation deviation in wrist motion training. The torque-field controller can be customized to different levels of rehabilitation training requirements by tuning the field parameters. Additionally, a rapidly convergent parameter self-identification algorithm is developed to obtain the uncertain parameters automatically for the floating wearable structure of the CDWRR. Finally, experiments on a healthy subject are carried out to demonstrate the performance of the controller and the feasibility of the CDWRR on wrist motion training or assistance.

  13. A cable-driven wrist robotic rehabilitator using a novel torque-field controller for human motion training

    NASA Astrophysics Data System (ADS)

    Chen, Weihai; Cui, Xiang; Zhang, Jianbin; Wang, Jianhua

    2015-06-01

    Rehabilitation technologies have great potentials in assisted motion training for stroke patients. Considering that wrist motion plays an important role in arm dexterous manipulation of activities of daily living, this paper focuses on developing a cable-driven wrist robotic rehabilitator (CDWRR) for motion training or assistance to subjects with motor disabilities. The CDWRR utilizes the wrist skeletal joints and arm segments as the supporting structure and takes advantage of cable-driven parallel design to build the system, which brings the properties of flexibility, low-cost, and low-weight. The controller of the CDWRR is designed typically based on a virtual torque-field, which is to plan "assist-as-needed" torques for the spherical motion of wrist responding to the orientation deviation in wrist motion training. The torque-field controller can be customized to different levels of rehabilitation training requirements by tuning the field parameters. Additionally, a rapidly convergent parameter self-identification algorithm is developed to obtain the uncertain parameters automatically for the floating wearable structure of the CDWRR. Finally, experiments on a healthy subject are carried out to demonstrate the performance of the controller and the feasibility of the CDWRR on wrist motion training or assistance.

  14. Upper limb joint kinetic analysis during tennis serve: Assessment of competitive level on efficiency and injury risks.

    PubMed

    Martin, C; Bideau, B; Ropars, M; Delamarche, P; Kulpa, R

    2014-08-01

    The aim of this work was to compare the joint kinetics and stroke production efficiency for the shoulder, elbow, and wrist during the serve between professionals and advanced tennis players and to discuss their potential relationship with given overuse injuries. Eleven professional and seven advanced tennis players were studied with an optoelectronic motion analysis system while performing serves. Normalized peak kinetic values of the shoulder, elbow, and wrist joints were calculated using inverse dynamics. To measure serve efficiency, all normalized peak kinetic values were divided by ball velocity. t-tests were used to determine significant differences between the resultant joint kinetics and efficiency values in both groups (advanced vs professional). Shoulder inferior force, shoulder anterior force, shoulder horizontal abduction torque, and elbow medial force were significantly higher in advanced players. Professional players were more efficient than advanced players, as they maximize ball velocity with lower joint kinetics. Since advanced players are subjected to higher joint kinetics, the results suggest that they appeared more susceptible to high risk of shoulder and elbow injuries than professionals, especially during the cocking and deceleration phases of the serve. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Compliant Robot Wrist

    NASA Technical Reports Server (NTRS)

    Voellmer, George

    1992-01-01

    Compliant element for robot wrist accepts small displacements in one direction only (to first approximation). Three such elements combined to obtain translational compliance along three orthogonal directions, without rotational compliance along any of them. Element is double-blade flexure joint in which two sheets of spring steel attached between opposing blocks, forming rectangle. Blocks moved parallel to each other in one direction only. Sheets act as double cantilever beams deforming in S-shape, keeping blocks parallel.

  16. Joint Inflammation and Early Degeneration Induced by High-Force Reaching Are Attenuated by Ibuprofen in an Animal Model of Work-Related Musculoskeletal Disorder

    PubMed Central

    Driban, Jeffrey B.; Barr, Ann E.; Amin, Mamta; Sitler, Michael R.; Barbe, Mary F.

    2011-01-01

    We used our voluntary rat model of reaching and grasping to study the effect of performing a high-repetition and high-force (HRHF) task for 12 weeks on wrist joints. We also studied the effectiveness of ibuprofen, administered in the last 8 weeks, in attenuating HRHF-induced changes in these joints. With HRHF task performance, ED1+ and COX2+ cells were present in subchondral radius, carpal bones and synovium; IL-1alpha and TNF-alpha increased in distal radius/ulna/carpal bones; chondrocytes stained with Terminal deoxynucleotidyl Transferase- (TDT-) mediated dUTP-biotin nick end-labeling (TUNEL) increased in wrist articular cartilages; superficial structural changes (e.g., pannus) and reduced proteoglycan staining were observed in wrist articular cartilages. These changes were not present in normal controls or ibuprofen treated rats, although IL-1alpha was increased in reach limbs of trained controls. HRHF-induced increases in serum C1,2C (a biomarker of collagen I and II degradation), and the ratio of collagen degradation to synthesis (C1,2C/CPII; the latter a biomarker of collage type II synthesis) were also attenuated by ibuprofen. Thus, ibuprofen treatment was effective in attenuating HRHF-induced inflammation and early articular cartilage degeneration. PMID:21403884

  17. Load compensating reactions to perturbations at wrist joint in normal man

    NASA Technical Reports Server (NTRS)

    Jaeger, R. J.; Agarwell, G. C.; Gottlieb, G. L.

    1981-01-01

    The electromyographic responses to step torque loads were studied in flexors and extensors at the human wrist. Based on temporal bursting patterns and functional behavior, the response was divided into four temporal components. Two early components, the myotatic (30-60 ms) late myotatic (60-120 ms) appears to be reflex response. The third postmyotatic component (120-200 ms) appear to be a triggered reaction, preceeding the fourth, stabilizing component (200-400 ms). A comparison of response at the wrist with similar data at the ankle provides the basis for a generalized classification of the response in various muscles to torque step perturbations.

  18. Wrist muscle activity of khatrah approach in Mameluke technique using traditional bow archery

    NASA Astrophysics Data System (ADS)

    Ariffin, Muhammad Shahimi; Rambely, Azmin Sham; Ariff, Noratiqah Mohd

    2018-04-01

    An investigation of khatrah technique in archery was carried out. An electromyography (EMG) experiment was conducted towards six wrist muscles which are flexor carpi radialis, extensor carpi ulnaris and extensor digitorum communis for both arms. The maximum voluntary contraction (MVC) and activity data were recorded. The bow arm produced a higher muscle force compared to draw arm muscles during release phase. However, the muscle forces produced by bow arm had a consistency in term of pattern throughout the phases. In conclusion, the forces generated by the professional archer produced a force benchmark at the wrist joint to alleviate the risk of injury.

  19. Design and evaluation of a slave manipulator with roll-pitch-roll wrist and automatic tool loading mechanism in telerobotic surgery.

    PubMed

    Kim, Ki-Young; Lee, Jung-Ju

    2012-12-01

    As there is a shortage of scrub nurses in many hospitals, automatic surgical tool exchanging mechanism without human labour has been studied. Minimally invasive robotic surgeries (MIRS) also require scrub nurses. A surgical tool loading mechanism without a scrub nurse's assistance for MIRS is proposed. Many researchers have developed minimally invasive surgical instruments with a wrist joint that can be movable inside the abdomen. However, implementation of a distal rolling joint on a gripper is rare. To implement surgical tool exchanging without a scrub nurse's assistance, a slave manipulator and a tool loader were developed to load and unload a surgical tool unit. A surgical tool unit with a roll-pitch-roll wrist was developed. Several experiments were performed to validate the effectiveness of the slave manipulator and the surgical tool unit. The slave manipulator and the tool loader were able to successfully unload and load the surgical tool unit without human assistance. The total duration of unloading and loading the surgical tool unit was 97 s. Motion tracking experiments of the distal rolling joint were performed. The maximum positioning error of the step input response was 2°. The advantage of the proposed slave manipulator and tool loader is that other robotic systems or human labour are not needed for surgical tool loading. The feasibility of the distal rolling joint in MIS is verified. Copyright © 2012 John Wiley & Sons, Ltd.

  20. Uncemented three-dimensional-printed prosthetic replacement for giant cell tumor of distal radius: a new design of prosthesis and surgical techniques.

    PubMed

    Lu, Minxun; Min, Li; Xiao, Cong; Li, Yongjiang; Luo, Yi; Zhou, Yong; Zhang, Wenli; Tu, Chongqi

    2018-01-01

    Currently, it is challenging to treat giant cell tumor (GCT) of distal radius. For Campanacci grade III or recurrent GCTs, en bloc resection has been accepted as a better treatment option. Although numerous methods are available for reconstruction, all of them have some limitations in joint function and complications. In this study, our aims were to treat the GCT of distal radius with uncemented three-dimensional (3D)-printed prosthesis and to present and evaluate the surgical techniques and short-term outcomes. Between September 2015 and March 2017, 11 patients with distal radius GCTs were treated with personalized uncemented 3D-printed prosthesis. The preoperative/postoperative pain, range of motion, and grip strengths of all patients were evaluated. Oncological results, complications, and degenerative changes in the wrist joint were evaluated. Functional outcomes were assessed according to the disabilities of the arm, shoulder, and hand (DASH) questionnaire and Mayo wrist scoring systems. The average follow-up was 14.45 months (range, 8-18 months). There was a significant decrease in the mean postoperative visual analog scale score (2.33) compared with the preoperative score (5.22; p <0.001). The mean DASH score and Mayo wrist score of the wrist joint function were 18.7 and 72, respectively. There was no local recurrence or lung metastasis. No complication associated with prosthesis was observed, including aseptic loosening, subluxation, and breakage. Joint space narrowing, or disuse osteoporosis, was also not found in all cases. En bloc resection and reconstruction with a personalized uncemented 3D-printed prosthesis can be alternative options to treat Campanacci grade III or recurrent GCTs of distal radius and can result in short-term oncologic salvage, good postoperative function, and low complication rate. However, a long-term follow-up is required to determine the outcome.

  1. Musculoskeletal model-based control interface mimics physiologic hand dynamics during path tracing task

    NASA Astrophysics Data System (ADS)

    Crouch, Dustin L.; (Helen Huang, He

    2017-06-01

    Objective. We investigated the feasibility of a novel, customizable, simplified EMG-driven musculoskeletal model for estimating coordinated hand and wrist motions during a real-time path tracing task. Approach. A two-degree-of-freedom computational musculoskeletal model was implemented for real-time EMG-driven control of a stick figure hand displayed on a computer screen. After 5-10 minutes of undirected practice, subjects were given three attempts to trace 10 straight paths, one at a time, with the fingertip of the virtual hand. Able-bodied subjects completed the task on two separate test days. Main results. Across subjects and test days, there was a significant linear relationship between log-transformed measures of accuracy and speed (Pearson’s r  =  0.25, p  <  0.0001). The amputee subject could coordinate movement between the wrist and MCP joints, but favored metacarpophalangeal joint motion more highly than able-bodied subjects in 8 of 10 trials. For able-bodied subjects, tracing accuracy was lower at the extremes of the model’s range of motion, though there was no apparent relationship between tracing accuracy and fingertip location for the amputee. Our result suggests that, unlike able-bodied subjects, the amputee’s motor control patterns were not accustomed to the multi-joint dynamics of the wrist and hand, possibly as a result of post-amputation cortical plasticity, disuse, or sensory deficits. Significance. To our knowledge, our study is one of very few that have demonstrated the real-time simultaneous control of multi-joint movements, especially wrist and finger movements, using an EMG-driven musculoskeletal model, which differs from the many data-driven algorithms that dominate the literature on EMG-driven prosthesis control. Real-time control was achieved with very little training and simple, quick (~15 s) calibration. Thus, our model is potentially a practical and effective control platform for multifunctional myoelectric prostheses that could restore more life-like hand function for individuals with upper limb amputation.

  2. Prevalence of joint-related pain in the extremities and spine in five groups of top athletes.

    PubMed

    Jonasson, Pall; Halldin, Klas; Karlsson, Jon; Thoreson, Olof; Hvannberg, Jonas; Swärd, Leif; Baranto, Adad

    2011-09-01

    Joint-related pain conditions from the spine and extremities are common among top athletes. The frequency of back pain has, however, been studied in more detail, and the frequency of low-back pain in top athletes in different high-load sports has been reported to be as high as 85%. Sport-related pain from different joints in the extremities is, however, infrequently reported on in the literature. Seventy-five male athletes, i.e. divers, weight-lifters, wrestlers, orienteers and ice-hockey players and 12 non-athletes (control group) were included in the study. A specific self-assessed pain-oriented questionnaire related to the cervical, thoracic and lumbar spine, as well as the various joints, i.e. shoulders, elbows, wrists, hips, knees and ankles, was filled out by the athletes and the non-athletes. The overall frequency of pain reported by the athletes during the last week/last year was as follows; cervical spine 35/55%; thoracic spine 22/33%; lumbar spine 50/68%; shoulder 10/21%; elbow 7/7%; wrist 7/8%; hip 15/23%; knee 22/44%; and ankle 11/25%. The corresponding values for non-athletes were cervical spine 9/36%; thoracic spine 17/33%; lumbar spine 36/50%; shoulder 0/9%; elbow 9/0%; wrist 0/0%; hip 9/16%; knee 10/9%; and ankle 0/0%. A higher percentage of athletes reported pain in almost all joint regions, but there were no statistically significant differences (n.s.), with the exception of the knees (P = 0.05). Over the last year, athletes reporting the highest pain frequency in the lumbar spine were ice-hockey players and, in the cervical spine, wrestlers and ice-hockey players. The highest levels of knee pain were found among wrestlers and ice-hockey players, whereas the highest levels for wrist pain were found among divers, hip pain among weight-lifters, orienteers and divers and ankle pain among orienteers. For the thoracic spine, shoulder and elbow regions, only minor differences were found. There was no statistically significant difference in prevalence of pain in the neck, spine and joints between top athletes in different sports or between athletes and non-athletes. However, pain in one spinal region was correlated to reported pain in other regions of the spine. Moreover, pain in the spine was also correlated to pain in the shoulders, hips and knees.

  3. Neuromuscular properties of different spastic human joints vary systematically.

    PubMed

    Mirbagheri, M M; Settle, K

    2010-01-01

    We quantified the mechanical abnormalities of the spastic wrist in chronic stroke survivors, and determined whether these findings were representative of those recorded at the elbow and ankle joints. System identification techniques were used to characterize the mechanical abnormalities of these joints and to identify the contribution of intrinsic and reflex stiffness to these abnormalities. Modulation of intrinsic and reflex stiffness with the joint angle was studied by applying PRBS perturbations to the joints at different joint angles over the range of motion. Age-matched healthy subjects were used as control.

  4. A Neuromuscular Electrical Stimulation (NMES) and robot hybrid system for multi-joint coordinated upper limb rehabilitation after stroke.

    PubMed

    Rong, Wei; Li, Waiming; Pang, Mankit; Hu, Junyan; Wei, Xijun; Yang, Bibo; Wai, Honwah; Zheng, Xiaoxiang; Hu, Xiaoling

    2017-04-26

    It is a challenge to reduce the muscular discoordination in the paretic upper limb after stroke in the traditional rehabilitation programs. In this study, a neuromuscular electrical stimulation (NMES) and robot hybrid system was developed for multi-joint coordinated upper limb physical training. The system could assist the elbow, wrist and fingers to conduct arm reaching out, hand opening/grasping and arm withdrawing by tracking an indicative moving cursor on the screen of a computer, with the support from the joint motors and electrical stimulations on target muscles, under the voluntary intention control by electromyography (EMG). Subjects with chronic stroke (n = 11) were recruited for the investigation on the assistive capability of the NMES-robot and the evaluation of the rehabilitation effectiveness through a 20-session device assisted upper limb training. In the evaluation, the movement accuracy measured by the root mean squared error (RMSE) during the tracking was significantly improved with the support from both the robot and NMES, in comparison with those without the assistance from the system (P < 0.05). The intra-joint and inter-joint muscular co-contractions measured by EMG were significantly released when the NMES was applied to the agonist muscles in the different phases of the limb motion (P < 0.05). After the physical training, significant improvements (P < 0.05) were captured by the clinical scores, i.e., Modified Ashworth Score (MAS, the elbow and the wrist), Fugl-Meyer Assessment (FMA), Action Research Arm Test (ARAT), and Wolf Motor Function Test (WMFT). The EMG-driven NMES-robotic system could improve the muscular coordination at the elbow, wrist and fingers. ClinicalTrials.gov. NCT02117089 ; date of registration: April 10, 2014.

  5. Estimation of tissue stiffness, reflex activity, optimal muscle length and slack length in stroke patients using an electromyography driven antagonistic wrist model.

    PubMed

    de Gooijer-van de Groep, Karin L; de Vlugt, Erwin; van der Krogt, Hanneke J; Helgadóttir, Áróra; Arendzen, J Hans; Meskers, Carel G M; de Groot, Jurriaan H

    2016-06-01

    About half of all chronic stroke patients experience loss of arm function coinciding with increased stiffness, reduced range of motion and a flexed wrist due to a change in neural and/or structural tissue properties. Quantitative assessment of these changes is of clinical importance, yet not trivial. The goal of this study was to quantify the neural and structural properties contributing to wrist joint stiffness and to compare these properties between healthy subjects and stroke patients. Stroke patients (n=32) and healthy volunteers (n=14) were measured using ramp-and-hold rotations applied to the wrist joint by a haptic manipulator. Neural (reflexive torque) and structural (connective tissue stiffness and slack lengths and (contractile) optimal muscle lengths) parameters were estimated using an electromyography driven antagonistic wrist model. Kruskal-Wallis analysis with multiple comparisons was used to compare results between healthy subjects, stroke patients with modified Ashworth score of zero and stroke patients with modified Ashworth score of one or more. Stroke patients with modified Ashworth score of one or more differed from healthy controls (P<0.05) by increased tissue stiffness, increased reflexive torque, decreased optimal muscle length and decreased slack length of connective tissue of the flexor muscles. Non-invasive quantitative analysis, including estimation of optimal muscle lengths, enables to identify neural and non-neural changes in chronic stroke patients. Monitoring these changes in time is important to understand the recovery process and to optimize treatment. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. [Arthroscopically assisted transcapsular refixation of the triangular fibrocartilage complex of the wrist].

    PubMed

    Pillukat, T; Fuhrmann, R A; Windolf, J; van Schoonhoven, J

    2016-08-01

    Refixation of the triangular fibrocartilage complex (TFCC) to the ulnar capsule of the wrist. Distal TFCC tears without instability, proximal TFCC intact. Loose ulnar TFCC attachment without tear or instability. Peripheral TFCC tears with instability of the distal radioulnar joint (DRUJ). Complex or proximal tears of the TFCC. Isolated, central degenerative tears without healing potential. Arthroscopically guided, minimally invasive suture of the TFCC to the base of the sixth extensor compartment. Above elbow plaster splint, 70° flexion of the elbow joint, 45° supination for 6 weeks. Skin suture removal after 2 weeks. No physiotherapy to extend pronation and supination during the first 3 months. In an ongoing long-term study, 7 of 31 patients who underwent transcapsular refixation of the TFCC between 1 January 2003 and 31 December 2010 were evaluated after an average follow-up interval of 116 ± 34 months (range 68-152 months). All patients demonstrated an almost nearly unrestricted range of wrist motion and grip strength compared to the unaffected side. All distal radioulnar joints were stable. On the visual analogue scale (VAS 0-10), pain at rest was 1 ± 1 (range 0-2) and pain during exercise 2 ± 2 (range 0-5); the DASH score averaged 10 ± 14 points (range 0-39 points). All patients were satisfied. The modified Mayo wrist score showed four excellent, two good, and one fair result. These results correspond to the results of other series. Transcapsular refixation is a reliable, technically simple procedure in cases with ulnar-sided TFCC tears without instability leading to good results.

  7. Does "hidden undercuffing" occur among obese patients? Effect of arm sizes and other predictors of the difference between wrist and upper arm blood pressures.

    PubMed

    Doshi, Hardik; Weder, Alan B; Bard, Robert L; Brook, Robert D

    2010-02-01

    Arm size can affect the accuracy of blood pressure (BP) measurement, and "undercuffing" of large upper arms is likely to be a growing problem. Therefore, the authors investigated the relationship between upper arm and wrist readings. Upper arm and wrist circumferences and BP were measured in 261 consecutive patients. Upper arm auscultation and wrist BP was measured in triplicate, rotating measurements every 30 seconds between sites. Upper arm BP was 131.9+/-20.6/71.6+/-12.6 mm Hg in an obese population (body mass index, 30.6+/-6.6 kg/m(2)) with mean upper arm size of 30.7+/-5.1 cm. Wrist BP was higher (2.6+/-9.2 mm Hg and 4.9+/-6.6 mm Hg, respectively, P<.001); however, there was moderate concordance for the Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure (JNC 7) strata (kappa value=0.27-0.71), and the difference was >or=5 mm Hg in 72% of the patients. The authors conclude that there was poor concordance between arm and wrist BP measurement and found no evidence that "hidden undercuffing" was associated with obesity; therefore, they do not support routine use of wrist BP measurements.

  8. Age-Related Decline of Wrist Position Sense and its Relationship to Specific Physical Training

    PubMed Central

    Van de Winckel, Ann; Tseng, Yu-Ting; Chantigian, Daniel; Lorant, Kaitlyn; Zarandi, Zinat; Buchanan, Jeffrey; Zeffiro, Thomas A.; Larson, Mia; Olson-Kellogg, Becky; Konczak, Jürgen; Keller-Ross, Manda L.

    2017-01-01

    Perception of limb and body positions is known as proprioception. Sensory feedback, especially from proprioceptive receptors, is essential for motor control. Aging is associated with a decline in position sense at proximal joints, but there is inconclusive evidence of distal joints being equally affected by aging. In addition, there is initial evidence that physical activity attenuates age-related decline in proprioception. Our objectives were, first, to establish wrist proprioceptive acuity in a large group of seniors and compare their perception to young adults, and second, to determine if specific types of training or regular physical activity are associated with preserved wrist proprioception. We recruited community-dwelling seniors (n = 107, mean age, 70 ± 5 years, range, 65–84 years) without cognitive decline (Mini Mental State Examination-brief version ≥13/16) and young adult students (n = 51, mean age, 20 ± 1 years, range, 19–26 years). Participants performed contralateral and ipsilateral wrist position sense matching tasks with a bimanual wrist manipulandum to a 15° flexion reference position. Systematic error or proprioceptive bias was computed as the mean difference between matched and reference position. The respective standard deviation over five trials constituted a measure of random error or proprioceptive precision. Current levels of physical activity and previous sport, musical, or dance training were obtained through a questionnaire. We employed longitudinal mixed effects linear models to calculate the effects of trial number, sex, type of matching task and age on wrist proprioceptive bias and precision. The main results were that relative proprioceptive bias was greater in older when compared to young adults (mean difference: 36% ipsilateral, 88% contralateral, p < 0.01). Proprioceptive precision for contralateral but not for ipsilateral matching was smaller in older than in young adults (mean difference: 38% contralateral, p < 0.01). Longer years of dance training were associated with smaller bias during ipsilateral matching (p < 0.01). Other types of training or physical activity levels did not affect bias or precision. Our findings demonstrate that aging is associated with a decline in proprioceptive bias in distal arm joints, but age does not negatively affect proprioceptive precision. Further, specific types of long-term dance related training may attenuate age-related decline in proprioceptive bias. PMID:29209188

  9. Age-Related Decline of Wrist Position Sense and its Relationship to Specific Physical Training.

    PubMed

    Van de Winckel, Ann; Tseng, Yu-Ting; Chantigian, Daniel; Lorant, Kaitlyn; Zarandi, Zinat; Buchanan, Jeffrey; Zeffiro, Thomas A; Larson, Mia; Olson-Kellogg, Becky; Konczak, Jürgen; Keller-Ross, Manda L

    2017-01-01

    Perception of limb and body positions is known as proprioception. Sensory feedback, especially from proprioceptive receptors, is essential for motor control. Aging is associated with a decline in position sense at proximal joints, but there is inconclusive evidence of distal joints being equally affected by aging. In addition, there is initial evidence that physical activity attenuates age-related decline in proprioception. Our objectives were, first, to establish wrist proprioceptive acuity in a large group of seniors and compare their perception to young adults, and second, to determine if specific types of training or regular physical activity are associated with preserved wrist proprioception. We recruited community-dwelling seniors ( n = 107, mean age, 70 ± 5 years, range, 65-84 years) without cognitive decline (Mini Mental State Examination-brief version ≥13/16) and young adult students ( n = 51, mean age, 20 ± 1 years, range, 19-26 years). Participants performed contralateral and ipsilateral wrist position sense matching tasks with a bimanual wrist manipulandum to a 15° flexion reference position. Systematic error or proprioceptive bias was computed as the mean difference between matched and reference position. The respective standard deviation over five trials constituted a measure of random error or proprioceptive precision . Current levels of physical activity and previous sport, musical, or dance training were obtained through a questionnaire. We employed longitudinal mixed effects linear models to calculate the effects of trial number, sex, type of matching task and age on wrist proprioceptive bias and precision. The main results were that relative proprioceptive bias was greater in older when compared to young adults (mean difference: 36% ipsilateral, 88% contralateral, p < 0.01). Proprioceptive precision for contralateral but not for ipsilateral matching was smaller in older than in young adults (mean difference: 38% contralateral, p < 0.01). Longer years of dance training were associated with smaller bias during ipsilateral matching ( p < 0.01). Other types of training or physical activity levels did not affect bias or precision. Our findings demonstrate that aging is associated with a decline in proprioceptive bias in distal arm joints, but age does not negatively affect proprioceptive precision. Further, specific types of long-term dance related training may attenuate age-related decline in proprioceptive bias.

  10. Fundamental Principles of Tremor Propagation in the Upper Limb.

    PubMed

    Davidson, Andrew D; Charles, Steven K

    2017-04-01

    Although tremor is the most common movement disorder, there exist few effective tremor-suppressing devices, in part because the characteristics of tremor throughout the upper limb are unknown. To clarify, optimally suppressing tremor requires a knowledge of the mechanical origin, propagation, and distribution of tremor throughout the upper limb. Here we present the first systematic investigation of how tremor propagates between the shoulder, elbow, forearm, and wrist. We simulated tremor propagation using a linear, time-invariant, lumped-parameter model relating joint torques and the resulting joint displacements. The model focused on the seven main degrees of freedom from the shoulder to the wrist and included coupled joint inertia, damping, and stiffness. We deliberately implemented a simple model to focus first on the most basic effects. Simulating tremorogenic joint torque as a sinusoidal input, we used the model to establish fundamental principles describing how input parameters (torque location and frequency) and joint impedance (inertia, damping, and stiffness) affect tremor propagation. We expect that the methods and principles presented here will serve as the groundwork for future refining studies to understand the origin, propagation, and distribution of tremor throughout the upper limb in order to enable the future development of optimal tremor-suppressing devices.

  11. Fundamental Principles of Tremor Propagation in the Upper Limb

    PubMed Central

    Davidson, Andrew D.; Charles, Steven K.

    2017-01-01

    Although tremor is the most common movement disorder, there exist few effective tremor-suppressing devices, in part because the characteristics of tremor throughout the upper limb are unknown. To clarify, optimally suppressing tremor requires a knowledge of the mechanical origin, propagation, and distribution of tremor throughout the upper limb. Here we present the first systematic investigation of how tremor propagates between the shoulder, elbow, forearm, and wrist. We simulated tremor propagation using a linear, time-invariant, lumped-parameter model relating joint torques and the resulting joint displacements. The model focused on the seven main degrees of freedom from the shoulder to the wrist and included coupled joint inertia, damping, and stiffness. We deliberately implemented a simple model to focus first on the most basic effects. Simulating tremorogenic joint torque as a sinusoidal input, we used the model to establish fundamental principles describing how input parameters (torque location and frequency) and joint impedance (inertia, damping, and stiffness) affect tremor propagation. We expect that the methods and principles presented here will serve as the groundwork for future refining studies to understand the origin, propagation, and distribution of tremor throughout the upper limb in order to enable the future development of optimal tremor-suppressing devices. PMID:27957608

  12. A Conceptual Project of a Device for Human Wrist Functional Rehabilitation

    NASA Astrophysics Data System (ADS)

    Lewandowski, B.; Olinski, M.; Wudarczyk, S.; Gronowicz, A.

    2016-12-01

    In the paper, the problems of devices supporting functional rehabilitation of a human wrist were addressed. A literature review and a description of selected devices together with an indication of their advantages and disadvantages were conducted. The biomechanical structure of a human wrist was analyzed. On this basis and after taking into consideration ranges of motion of the selected joints the concept of a new mechanism was developed. A 3D model of the device was built in the Autodesk Inventor system. For the purpose of simulations another model was developed in the MSC Adams system. Issues of drives and sensors selection, as well as requirements for the control system, were examined.

  13. The Effect of Supination and Pronation on Wrist Range of Motion

    PubMed Central

    Kane, Patrick M.; Vopat, Bryan G.; Got, Christopher; Mansuripur, Kaveh; Akelman, Edward

    2014-01-01

    Wrist range of motion (ROM) is a combination of complex osseous articulations and intricate soft tissue constraints. It has been proposed that forearm rotation contributes significantly to carpal kinematics. However, no studies have investigated whether supination or pronation influence this course of motion. The purpose of this study is to examine whether supination and pronation affect the mechanical axis of the wrist. After being screened for gross anatomic abnormalities, six upper extremity cadaver specimens (three matched pairs) were fixed to a custom-designed jig that allows 24 different directions of wrist motion. Each specimen was tested in three separate forearm positions: neutral, full supination, and full pronation. Moments of ± 2 Nm were applied, and the applied moment versus wrist rotation data were recorded. Forearm position did not significantly (p > 0.31) affect the ROM values of the wrist. In forearm neutral, supination, and pronation positions the envelope of wrist ROM values was ellipsoidal in shape, consistent with prior neutral forearm biomechanical testing. The major axis of the ellipse was oriented in a radial extension to ulnar flexion direction, with the largest ROM in ulnar flexion. We hypothesized that forearm position would influence wrist ROM. However, our biomechanical testing showed no statistically significant difference in the orientation of the mechanical axis nor the passive ROM of the wrist. The primary passive mechanical axis in all three forearm positions tested (neutral, supination, and pronation) was aligned with radial extension and ulnar flexion. Although it has been shown that forearm position affects various radioulnar, radiocarpal, and ulnocarpal ligamentous tensions and lengths, it appears that wrist ROM is independent of forearm position. Consequently we feel our biomechanical testing illustrates that wrist ROM is primarily dependent on the osseous articulations of the carpus. Additionally, given that no change is observed in wrist ROM relative to forearm position, the significance of the contribution of the distal radioulnar joint (DRUJ) to wrist kinematics is debatable. PMID:25097812

  14. Cartilage quantification using contrast-enhanced MRI in the wrist of rheumatoid arthritis: cartilage loss is associated with bone marrow edema.

    PubMed

    Fujimori, Motoshi; Nakamura, Satoko; Hasegawa, Kiminori; Ikeno, Kunihiro; Ichikawa, Shota; Sutherland, Kenneth; Kamishima, Tamotsu

    2017-08-01

    To quantify wrist cartilage using contrast MRI and compare with the extent of adjacent synovitis and bone marrow edema (BME) in patients with rheumatoid arthritis (RA). 18 patients with RA underwent post-contrast fat-suppressed T 1 weighted coronal imaging. Cartilage area at the centre of the scaphoid-capitate and radius-scaphoid joints was measured by in-house developed software. We defined cartilage as the pixels with signal intensity between two thresholds (lower: 0.4, 0.5 and 0.6 times the muscle signal, upper: 0.9, 1.0, 1.1, 1.2 and 1.3 times the muscle signal). We investigated the association of cartilage loss with synovitis and BME score derived from RA MRI scoring system. Cartilage area was correlated with BME score when thresholds were adequately set with lower threshold at 0.6 times the muscle signal and upper threshold at 1.2 times the muscle signal for both SC (r s =-0.469, p < 0.05) and RS (r s =-0.486, p < 0.05) joints, while it showed no significant correlation with synovitis score at any thresholds. Our software can accurately quantify cartilage in the wrist and BME associated with cartilage loss in patients with RA. Advances in knowledge: Our software can quantify cartilage using conventional MR images of the wrist. BME is associated with cartilage loss in RA patients.

  15. Clinical Assessment and Diagnostics of Patients With Hand Disorders: A Case Study Approach.

    PubMed

    Leow, Mabel Qi He; Lim, Rebecca Qian Ru; Tay, Shian Chao

    Clinical assessment of the hand is important for diagnosing underlying hand disorders. Using a case study approach, the clinical assessment for three disorders of the hands is presented: trigger finger (stenosing tenosynovitis), carpal tunnel syndrome, and ulnar-sided wrist injury (styloid impingement). We assess the annular one pulley and finger range of motion for patients with trigger finger. To diagnose for carpal tunnel syndrome, assessment for Tinel's sign, Phalen's sign, abductor pollicis brevis muscle bulk, two-point discrimination, and obtaining a nerve conduction study are performed. Assessment for ulnar-sided wrist injury includes wrist range of motion, assessment of distal radial ulnar joint stability, provocation tests, grip strength, x-ray, and magnetic resonance imaging. This article begins with a description of the hand and wrist anatomy. For each case study, the clinical history is described, followed by a discussion of the pathophysiology, clinical assessments, and diagnostic tests.

  16. Design of a Lightweight Soft Robotic Arm Using Pneumatic Artificial Muscles and Inflatable Sleeves.

    PubMed

    Ohta, Preston; Valle, Luis; King, Jonathan; Low, Kevin; Yi, Jaehyun; Atkeson, Christopher G; Park, Yong-Lae

    2018-04-01

    As robots begin to interact with humans and operate in human environments, safety becomes a major concern. Conventional robots, although reliable and consistent, can cause injury to anyone within its range of motion. Soft robotics, wherein systems are made to be soft and mechanically compliant, are thus a promising alternative due to their lightweight nature and ability to cushion impacts, but current designs often sacrifice accuracy and usefulness for safety. We, therefore, have developed a bioinspired robotic arm combining elements of rigid and soft robotics such that it exhibits the positive qualities of both, namely compliance and accuracy, while maintaining a low weight. This article describes the design of a robotic arm-wrist-hand system with seven degrees of freedom (DOFs). The shoulder and elbow each has two DOFs for two perpendicular rotational motions on each joint, and the hand has two DOFs for wrist rotations and one DOF for a grasp motion. The arm is pneumatically powered using custom-built McKibben type pneumatic artificial muscles, which are inflated and deflated using binary and proportional valves. The wrist and hand motions are actuated through servomotors. In addition to the actuators, the arm is equipped with a potentiometer in each joint for detecting joint angle changes. Simulation and experimental results for closed-loop position control are also presented in the article.

  17. Evaluating Suit Fit Using Performance Degradation

    NASA Technical Reports Server (NTRS)

    Margerum, Sarah E.; Cowley, Matthew; Harvill, Lauren; Benson, Elizabeth; Rajulu, Sudhakar

    2012-01-01

    The Mark III planetary technology demonstrator space suit can be tailored to an individual by swapping the modular components of the suit, such as the arms, legs, and gloves, as well as adding or removing sizing inserts in key areas. A method was sought to identify the transition from an ideal suit fit to a bad fit and how to quantify this breakdown using a metric of mobility-based human performance data. To this end, the degradation of the range of motion of the elbow and wrist of the suit as a function of suit sizing modifications was investigated to attempt to improve suit fit. The sizing range tested spanned optimal and poor fit and was adjusted incrementally in order to compare each joint angle across five different sizing configurations. Suited range of motion data were collected using a motion capture system for nine isolated and functional tasks utilizing the elbow and wrist joints. A total of four subjects were tested with motions involving both arms simultaneously as well as the right arm by itself. Findings indicated that no single joint drives the performance of the arm as a function of suit size; instead it is based on the interaction of multiple joints along a limb. To determine a size adjustment range where an individual can operate the suit at an acceptable level, a performance detriment limit was set. This user-selected limit reveals the task-dependent tolerance of the suit fit around optimal size. For example, the isolated joint motion indicated that the suit can deviate from optimal by as little as -0.6 in to -2.6 in before experiencing a 10% performance drop in the wrist or elbow joint. The study identified a preliminary method to quantify the impact of size on performance and developed a new way to gauge tolerances around optimal size.

  18. Predictive value of bone scintigraphy for the detection of joint involvement in Behçet's disease: Dermatologists' perspectives.

    PubMed

    Seo, Jimyung; Lee, Minseok; Choi, Min Ju; Zheng, Zhenlong; Cho, Arthur; Bang, Dongsik; Kim, Do Young

    2015-01-01

    Behçet's disease (BD) is a multisystemic inflammatory disease with articular involvement. Non-specific arthralgia without objective signs of arthritis, such as swelling or effusion, is common in such patients. Thus, an accurate diagnosis of joint involvement may be challenging for dermatologists. To evaluate the validity of (99m)Tc-methylene diphosphonate (Tc-99m-MDP) bone scintigraphy for joint involvement assessment in patients with BD. In 211 patients with BD who had scintigraphic evaluations due to joint symptoms, agreement between bone scintigraphy findings and clinically evaluated joint complaints was retrospectively assessed using Cohen's kappa (κ) statistic. A patient subset (n = 104) showing agreement between joint complaints and scintigraphy results was re-evaluated by a rheumatologist to determine the level of diagnostic specificity attained by combining bone scintigraphy with clinical examinations of dermatologists. The total kappa value (211 patients) was 0.604, indicating fair agreement between joint complaints and scintigraphy results. Individual analysis of eleven joint categories revealed statistically significant correlations for wrist (κ = 0.677), shoulder (κ = 0.661), and foot joints (κ = 0.618). Of the 104 referrals to a rheumatologist, 95 (91.34%) were confirmed as having BD-associated articular involvement. Joint acral areas (e.g., foot, hand, wrist and shoulder) that had the highest kappa value correlations also ranked highest in diagnostic specificity. Bone scintigraphy presents a simple and useful option for dermatologists to assess joint involvement in BD patients, especially for specific anatomic sites.

  19. Robot-aided developmental assessment of wrist proprioception in children.

    PubMed

    Marini, Francesca; Squeri, Valentina; Morasso, Pietro; Campus, Claudio; Konczak, Jürgen; Masia, Lorenzo

    2017-01-09

    Several neurodevelopmental disorders and brain injuries in children have been associated with proprioceptive dysfunction that will negatively affect their movement. Unfortunately, there is lack of reliable and objective clinical examination protocols and our current knowledge of how proprioception evolves in typically developing children is still sparse. Using a robotic exoskeleton, we investigated proprioceptive acuity of the wrist in a group of 49 typically developing healthy children (8-15 years), and a group of 40 young adults. Without vision participants performed an ipsilateral wrist joint position matching task that required them to reproduce (match) a previously experienced target position. All three joint degrees-of-freedom of the wrist/hand complex were assessed. Accuracy and precision were evaluated as a measure of proprioceptive acuity. The cross-sectional data indicating the time course of development of acuity were then fitted by four models in order to determine which function best describes developmental changes in proprioception across age. First, the robot-aided assessment proved to be an easy to administer method for objectively measuring proprioceptive acuity in both children and adult populations. Second, proprioceptive acuity continued to develop throughout middle childhood and early adolescence, improving by more than 50% with respect to the youngest group. Adult levels of performance were reached approximately by the age of 12 years. An inverse-root function best described the development of proprioceptive acuity across the age groups. Third, wrist/forearm proprioception is anisotropic across the three DoFs with the Abduction/Adduction exhibiting a higher level of acuity than those of Flexion/extension and Pronation/Supination. This anisotropy did not change across development. Proprioceptive development for the wrist continues well into early adolescence. Our normative data obtained trough this novel robot-aided assessment method provide a basis against which proprioceptive function of pediatric population can be compared. This may aid the design of more effective sensorimotor intervention programs.

  20. Dissection of a single rat muscle-tendon complex changes joint moments exerted by neighboring muscles: implications for invasive surgical interventions.

    PubMed

    Maas, Huub; Baan, Guus C; Huijing, Peter A

    2013-01-01

    The aim of this paper is to investigate mechanical functioning of a single skeletal muscle, active within a group of (previously) synergistic muscles. For this purpose, we assessed wrist angle-active moment characteristics exerted by a group of wrist flexion muscles in the rat for three conditions: (i) after resection of the upper arm skin; (ii) after subsequent distal tenotomy of flexor carpi ulnaris muscle (FCU); and (iii) after subsequent freeing of FCU distal tendon and muscle belly from surrounding tissues (MT dissection). Measurements were performed for a control group and for an experimental group after recovery (5 weeks) from tendon transfer of FCU to extensor carpi radialis (ECR) insertion. To assess if FCU tenotomy and MT dissection affects FCU contributions to wrist moments exclusively or also those of neighboring wrist flexion muscles, these data were compared to wrist angle-moment characteristics of selectively activated FCU. FCU tenotomy and MT dissection decreased wrist moments of the control group at all wrist angles tested, including also angles for which no or minimal wrist moments were measured when activating FCU exclusively. For the tendon transfer group, wrist flexion moment increased after FCU tenotomy, but to a greater extent than can be expected based on wrist extension moments exerted by selectively excited transferred FCU. We conclude that dissection of a single muscle in any surgical treatment does not only affect mechanical characteristics of the target muscle, but also those of other muscles within the same compartment. Our results demonstrate also that even after agonistic-to-antagonistic tendon transfer, mechanical interactions with previously synergistic muscles do remain present.

  1. Gender Differences in Capitate Kinematics are Eliminated After Accounting for Variation in Carpal Size

    PubMed Central

    Rainbow, Michael J.; Moore, Douglas C.; Wolfe, Scott W.

    2012-01-01

    Previous studies have found gender differences in carpal kinematics, and there are discrepancies in the literature on the location of the flexion/extension and radio-ulnar deviation rotation axes of the wrist. It has been postulated that these differences are due to carpal bone size differences rather than gender and that they may be resolved by normalizing the kinematics by carpal size. The purpose of this study was to determine if differences in radio-capitate kinematics are a function of size or gender. We also sought to determine if a best-fit pivot point (PvP) describes the radio-capitate joint as a ball-and-socket articulation. By using an in vivo markerless bone registration technique applied to computed tomography scans of 26 male and 28 female wrists, we applied scaling derived from capitate length to radio-capitate kinematics, characterized by a best-fit PvP. We determined if radio-capitate kinematics behave as a ball-and-socket articulation by examining the error in the best-fit PvP. Scaling PvP location completely removed gender differences (P = 0.3). This verifies that differences in radio-capitate kinematics are due to size and not gender. The radio-capitate joint did not behave as a perfect ball and socket because helical axes representing anatomical motions such as flexion-extension, radio-ulnar deviation, dart throwers, and antidart throwers, were located at distances up to 4.5 mm from the PvP. Although the best-fit PvP did not yield a single center of rotation, it was still consistently found within the proximal pole of the capitate, and rms errors of the best-fit PvP calculation were on the order of 2 mm. Therefore, the ball-and-socket model of the wrist joint center using the best-fit PvP is appropriate when considering gross motion of the hand with respect to the forearm such as in optical motion capture models. However, the ball-and-socket model of the wrist is an insufficient description of the complex motion of the capitate with respect to the radius. These findings may aid in the design of wrist external fixation and orthotics. PMID:18601445

  2. Simultaneous, proportional, multi-axis prosthesis control using multichannel surface EMG.

    PubMed

    Yatsenko, Dimitri; McDonnall, Daniel; Guillory, K Shane

    2007-01-01

    Most upper limb prosthesis controllers only allow the individual selection and control of single joints of the limb. The main limiting factor for simultaneous multi-joint control is usually the availability of reliable independent control signals that can intuitively be used. In this paper, a novel method is presented for extraction of individual muscle source signals from surface EMG array recordings, based on EMG energy orthonormalization along principle movement vectors. In cases where independently-controllable muscles are present in residual limbs, this method can be used to provide simultaneous, multi-axis, proportional control of prosthetic systems. Initial results are presented for simultaneous control of wrist rotation, wrist flexion/extension, and grip open/close for two intact subjects under both isometric and non-isometric conditions and for one subject with transradial amputation.

  3. Optimal wrist angulation shortens time needed for radial artery catheterization: a prospective, randomized, and blinded study.

    PubMed

    Pandey, R; Ashraf, H; Bhalla, A P; Garg, R

    2012-01-01

    Optimal wrist position is essential for successful catheterization of the radial artery. We planned to study the success rate of radial artery catheterization at various degrees of wrist extension angulations. This prospective, randomized study was performed in 60 consenting patients aged between 18-65 years and undergoing variable surgeries where the anesthetic management required an arterial catheterization. All patients were randomized into three groups of 20 patients each, according to wrist angulation during radial artery catheterization : either 30 degrees (Group 30), 45 degrees (Group 45), or 60 degrees (Group 60). Three metallic angulated wrist boards with angles of 30 degrees, 45 degrees, and 60 degrees (angle measured with calipers) were prepared, on which patient's wrist was kept at the above-mentioned angles of extension. Radial artery catheterization success rate, catheterization time, and numbers of attempts were recorded. The catheterization time was minimal in group 45 (30.50 +/- 16.82 sec) as compared to 36.00 +/- 14.19 sec and 43.50 +/- 13.80 sec in group 30 and 60, respectively. Radial artery was catheterized at first attempt in 60% of Group 45 and Group 60 patients, and in 50% of Group 30 patients. The arterial catheterization was successful in 14/20 patients in Group 30, 19/20 patients in group 45, and 16/20 patients in group 60. We conclude that a wrist extension of 450 appears to be the optimal wrist joint extension for a successful radial artery cannula insertion.

  4. Intervention randomized controlled trials involving wrist and shoulder arthroscopy: a systematic review

    PubMed Central

    2014-01-01

    Background Although arthroscopy of upper extremity joints was initially a diagnostic tool, it is increasingly used for therapeutic interventions. Randomized controlled trials (RCTs) are considered the gold standard for assessing treatment efficacy. We aimed to review the literature for intervention RCTs involving wrist and shoulder arthroscopy. Methods We performed a systematic review for RCTs in which at least one arm was an intervention performed through wrist arthroscopy or shoulder arthroscopy. PubMed and Cochrane Library databases were searched up to December 2012. Two researchers reviewed each article and recorded the condition treated, randomization method, number of randomized participants, time of randomization, outcomes measures, blinding, and description of dropouts and withdrawals. We used the modified Jadad scale that considers the randomization method, blinding, and dropouts/withdrawals; score 0 (lowest quality) to 5 (highest quality). The scores for the wrist and shoulder RCTs were compared with the Mann–Whitney test. Results The first references to both wrist and shoulder arthroscopy appeared in the late 1970s. The search found 4 wrist arthroscopy intervention RCTs (Kienböck’s disease, dorsal wrist ganglia, volar wrist ganglia, and distal radius fracture; first 3 compared arthroscopic with open surgery). The median number of participants was 45. The search found 50 shoulder arthroscopy intervention RCTs (rotator cuff tears 22, instability 14, impingement 9, and other conditions 5). Of these, 31 compared different arthroscopic treatments, 12 compared arthroscopic with open treatment, and 7 compared arthroscopic with nonoperative treatment. The median number of participants was 60. The median modified Jadad score for the wrist RCTs was 0.5 (range 0–1) and for the shoulder RCTs 3.0 (range 0–5) (p = 0.012). Conclusion Despite the increasing use of wrist arthroscopy in the treatment of various wrist disorders the efficacy of arthroscopically performed wrist interventions has been studied in only 4 randomized studies compared to 50 randomized studies of significantly higher quality assessing interventions performed through shoulder arthroscopy. PMID:25059881

  5. An inquiry into application of Gokyo (Aikido's Fifth Teaching) on human anatomy.

    PubMed

    Olson, G D; Seitz, F C; Guldbrandsen, F

    1996-06-01

    In this anatomical analysis the authors examined Gokyo, Aikido's Fifth Teaching. Using their cadaver/anatomist-observer model, the authors observed that tissues manipulated by the technique were primarily on the dorsal side of the wrist, proximal to the second metacarpal. The source of the pain was thought to involve the manipulation of the wrist joints and associated carpometacarpal ligaments. Locations of the manipulated tissue and sources of pain associated with that tissue, and their limited practical application were discussed.

  6. 38 CFR 4.45 - The joints.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... movement (due to muscle injury, disease or injury of peripheral nerves, divided or lengthened tendons, etc... the purpose of rating disability from arthritis, the shoulder, elbow, wrist, hip, knee, and ankle are...

  7. 38 CFR 4.45 - The joints.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... movement (due to muscle injury, disease or injury of peripheral nerves, divided or lengthened tendons, etc... the purpose of rating disability from arthritis, the shoulder, elbow, wrist, hip, knee, and ankle are...

  8. 38 CFR 4.45 - The joints.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... movement (due to muscle injury, disease or injury of peripheral nerves, divided or lengthened tendons, etc... the purpose of rating disability from arthritis, the shoulder, elbow, wrist, hip, knee, and ankle are...

  9. 38 CFR 4.45 - The joints.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... movement (due to muscle injury, disease or injury of peripheral nerves, divided or lengthened tendons, etc... the purpose of rating disability from arthritis, the shoulder, elbow, wrist, hip, knee, and ankle are...

  10. Variance in direct exposure measures of typing force and wrist kinematics across hours and days among office computer workers.

    PubMed

    Asundi, Krishna; Johnson, Peter W; Dennerlein, Jack T

    2012-01-01

    To determine the number of direct measurements needed to obtain a representative estimate of typing force and wrist kinematics, continuous measures of keyboard reaction force and wrist joint angle were collected at the workstation of 22 office workers while they completed their own work over three days, six hours per day. Typing force and wrist kinematics during keyboard, mouse and idle activities were calculated for each hour of measurement along with variance in measurements between subjects and between day and hour within subjects. Variance in measurements between subjects was significantly greater than variance in measurements between days and hours within subjects. Therefore, we concluded a single, one-hour period of continuous measures is sufficient to identify differences in typing force and wrist kinematics between subjects. Within subjects, day and hour of measurement had a significant effect on some measures and thus should be accounted for when comparing measures within a subject. The dose response relationship between exposure to computer related biomechanical risk factors and musculoskeletal disorders is poorly understood due to the difficulty and cost of direct measures. This study demonstrates a single hour of direct continuous measures is sufficient to identify differences in wrist kinematics and typing force between individuals.

  11. Handgrip strength and associated factors in hospitalized patients.

    PubMed

    Guerra, Rita S; Fonseca, Isabel; Pichel, Fernando; Restivo, Maria T; Amaral, Teresa F

    2015-03-01

    Handgrip strength (HGS) is a marker of nutrition status. Many factors are associated with HGS. Age, height, body mass index, number of diagnoses, and number and type of drugs have been shown to modify the association between undernutrition and HGS. Nevertheless, other patient characteristics that could modify this association and its joint modifier effect have not been studied yet. To evaluate the association of inpatients' HGS and undernutrition considering the potential modifier effect of cognitive status, functional activity, disease severity, anthropometrics, and other patient characteristics on HGS. A cross-sectional study was conducted in a university hospital. Sex, age, abbreviated mental test score, functional activity score, Charlson index, number of drugs, Patient-Generated Subjective Global Assessment (PG-SGA) score, body weight, mid-arm muscle circumference, adductor pollicis muscle thickness, body height, wrist circumference, hand length, and palm width were included in a linear regression model to identify independent factors associated with HGS (dependent variable). The study sample was composed of 688 inpatients (18-91 years old). All variables included in the model were associated with HGS (β, -0.16 to 0.38; P ≤ .049) and explained 68.5% of HGS. Age, functional activity decline, Charlson index, number of drugs, PG-SGA score, body weight, and wrist circumference had a negative association with HGS. All other studied variables were positively associated with HGS. Nutrition status evaluated by PG-SGA was still associated with HGS after considering the joint effect of other patient characteristics, which reinforces the value of HGS as an indicator of undernutrition. © 2013 American Society for Parenteral and Enteral Nutrition.

  12. Implant Failure After Motec Wrist Joint Prosthesis Due to Failure of Ball and Socket-Type Articulation-Two Patients With Adverse Reaction to Metal Debris and Polyether Ether Ketone.

    PubMed

    Karjalainen, Teemu; Pamilo, Konsta; Reito, Aleksi

    2018-04-21

    We describe 2 cases of articulation-related failures resulting in revision surgery after a Motec total wrist arthroplasty: one with an adverse reaction to metal debris and the other with an adverse reaction to polyether ether ketone. In the first patient, blood cobalt and chrome levels were elevated and magnetic resonance imaging showed clear signs of a pseudotumor. The other patient had an extensive release of polyether ether ketone particles into the surrounding synovia due to adverse wear conditions in the cup, leading to the formation of a fluid-filled cyst sac with a black lining and diffuse lymphocyte-dominated inflammation in the synovia. We recommend regular follow-up including x-rays, monitoring of cobalt and chrome ion levels, and a low threshold for cross-sectional imaging in patients who have undergone total wrist arthroplasty with a Motec joint prosthesis. Wear-related problems can also develop in implants in which polyether ether ketone is the bulk material. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  13. Intra-articular injection with triamcinolone hexacetonide in patients with rheumatoid arthritis: prospective assessment of goniometry and joint inflammation parameters.

    PubMed

    Furtado, Rita Nely Vilar; Machado, Flávia Soares; Luz, Karine Rodrigues da; Santos, Marla Francisca Dos; Konai, Monique Sayuri; Lopes, Roberta Vilela; Natour, Jamil

    To evaluate local joint variables after intra-articular injection with triamcinolone hexacetonide in rheumatoid arthritis patients. We blindly and prospectively (baseline, 1, 4, 12 and 24 weeks) evaluated metacarpophalangeal, wrist, elbow, shoulder, knee and ankle joints after triamcinolone hexacetonide intra-articular injection by the following outcome measures: visual analogue scale 0-10cm (VAS) for rest pain (VASR); VAS for movement pain (VASM); VAS for joint swelling (VASSw); flexion (FlexG) and extension (ExtG). 289 patients (635 joints) were studied. VASSw (p<0.001) and VASR (0.001

  14. Evaluating Suit Fit Using Performance Degradation

    NASA Technical Reports Server (NTRS)

    Margerum, Sarah E.; Cowley, Matthew; Harvill, Lauren; Benson, Elizabeth; Rajulu, Sudhakar

    2011-01-01

    The Mark III suit has multiple sizes of suit components (arm, leg, and gloves) as well as sizing inserts to tailor the fit of the suit to an individual. This study sought to determine a way to identify the point an ideal suit fit transforms into a bad fit and how to quantify this breakdown using mobility-based physical performance data. This study examined the changes in human physical performance via degradation of the elbow and wrist range of motion of the planetary suit prototype (Mark III) with respect to changes in sizing and as well as how to apply that knowledge to suit sizing options and improvements in suit fit. The methods implemented in this study focused on changes in elbow and wrist mobility due to incremental suit sizing modifications. This incremental sizing was within a range that included both optimum and poor fit. Suited range of motion data was collected using a motion analysis system for nine isolated and functional tasks encompassing the elbow and wrist joints. A total of four subjects were tested with motions involving both arms simultaneously as well as the right arm only. The results were then compared across sizing configurations. The results of this study indicate that range of motion may be used as a viable parameter to quantify at what stage suit sizing causes a detriment in performance; however the human performance decrement appeared to be based on the interaction of multiple joints along a limb, not a single joint angle. The study was able to identify a preliminary method to quantify the impact of size on performance and to develop a means to gauge tolerances around optimal size. More work is needed to improve the assessment of optimal fit and to compensate for multiple joint interactions.

  15. Complications of intra-articular injections of triamcinolone hexacetonide in chronic arthritis in children.

    PubMed

    Job-Deslandre, C; Menkes, C J

    1990-01-01

    Intra-articular injections of triamcinolone hexacetonide (THA) are a useful therapy in JRA and HLA B 27 related arthritis (B 27 RA). Published data have indicated good results and few side effects. We evaluate here the frequency of occurrence of local side effects in 35 children with JRA (115 joints treated) and 13 children with B 27 RA (29 joints treated). With a mean follow up of 25 months in JRA and 18 months in B 27 RA, we observed 12 cases (8.3%) of subcutaneous tissue atrophy with local depigmentation (knees 5 cases, wrists 2 cases, ankles 3 cases, metatarsophalangeal joints 2 cases) and 7 cases (4.9%) of intra-articular calcifications all in the JRA group (wrists 3 cases, knees 2 cases, ankles 2 cases). Youth and joint size are possible predisposing factors for subcutaneous tissue atrophy and intra-articular calcification. Spontaneous improvement previously reported for these local side effects was not observed in our study. These results underline the necessity of discussing on a case by case basis whether intra-articular, non long-acting corticosteroid or THA are indicated. THA must be injected with a rigorous technique and with a dosage adapted to the articular volume.

  16. The anatomy of Nikyo (Aikido's second teaching).

    PubMed

    Eckert, J W; Lee, T K

    1993-12-01

    Nikyo is the second teaching of Aikido (ni-two, kyo-teaching, in Japanese). It is a joint-lock technique that results in extreme pain. It allows one to control an opponent by destroying his will to continue fighting. Nikyo is accomplished by flexing and adducting an opponent's wrist producing an instantaneous sharp pain that causes him to fall to his knees involuntarily to alleviate the pressure. The exact etiology of the pain elicited by this technique has been obscure to many practitioners. The usual explanations have been nerve compression, joint capsular stretch, tendon/muscle strain, or partial ligamentous disruption. Studies of a cadaver's wrist have shown that Nikyo forcibly compresses the pisiform bone against the ulna, two bones that do not normally articulate. The intense pain thereby produced results from stimulation of the periosteal nerves in these bony surfaces.

  17. [Magnetic resonance imaging for the wrist joint of the coal miners in vibration department].

    PubMed

    Zhao, Xuan-zhi; Liu, Rui-lian; Hu, Shu-dong; Zhang, Wei; Xu, Wen-xiu; Ge, Ling-xia

    2006-04-01

    To study the magnetic resonance imaging (MRI) in the wrist joint of coal miners who work in excavation and vibration department. Forty-three coal miners with the hand-arm vibration disease served as the observation group while 20 workers who were not working in the vibration department acted as the control group. The patients in the observation group were divided into five subgroups according to the time when they received vibration. The regularity of the development of signs and symptoms of MRI was observed and analyzed. The hydroarthrosis was most found in MRI. There were significant difference in hydroarthrosis (chi(2) = 8.80, P < 0.01), osteoporosis and osteomyelitis (chi(2) = 3.91, chi(2) = 5.01, P < 0.05 respectively) between the observation group and the control group. The edema of bone marrow and the avascular necrosis of ossa carpi were found only in the observation group and not found in the control group. The hydroarthrosis and the edema of bone marrow occurred most in the early stage of vibration. The signal in the edema of the bone marrow of the distal end of the radius was decreased in the GE sequence T(2)WI with the specificity. (1) Changes in the wrist joint occur in the early stage of the vibration work, and can be found in the MRI. (2) The edema of the bone marrow of the distal end of the radius is of great value in the diagnosis of the hand-arm vibration disease.

  18. Medial Elbow Joint Space Increases With Valgus Stress and Decreases When Cued to Perform A Maximal Grip Contraction.

    PubMed

    Pexa, Brett S; Ryan, Eric D; Myers, Joseph B

    2018-04-01

    Previous research indicates that the amount of valgus torque placed on the elbow joint during overhead throwing is higher than the medial ulnar collateral ligament (UCL) can tolerate. Wrist and finger flexor muscle activity is hypothesized to make up for this difference, and in vitro studies that simulated activity of upper extremity musculature, specifically the flexor digitorum superficialis and flexor carpi ulnaris, support this hypothesis. To assess the medial elbow joint space at rest, under valgus stress, and under valgus stress with finger and forearm flexor contraction by use of ultrasonography in vivo. Controlled laboratory study. Participants were 22 healthy males with no history of elbow dislocation or UCL injury (age, 21.25 ± 1.58 years; height, 1.80 ± 0.08 m; weight, 79.43 ± 18.50 kg). Medial elbow joint space was measured by use of ultrasonography during 3 separate conditions: at rest (unloaded), under valgus load (loaded), and with a maximal grip contraction under a valgus load (loaded-contracted) in both limbs. Participants lay supine with their arm abducted 90° and elbow flexed 30° with the forearm in full supination. A handgrip dynamometer was placed in the participants' hand to grip against during the contracted condition. Images were reduced in ImageJ to assess medial elbow joint space. A 2-way (condition × limb) repeated-measures analysis of variance and Cohen's d effect sizes were used to assess changes in medial elbow joint space. Post hoc testing was performed with a Bonferroni adjustment to assess changes within limb and condition. The medial elbow joint space was significantly larger in the loaded condition (4.91 ± 1.16 mm) compared with the unloaded condition (4.26 ± 1.23 mm, P < .001, d = 0.712) and the loaded-contracted condition (3.88 ± 0.94 mm, P < .001, d = 1.149). No significant change was found between the unloaded and loaded-contracted conditions ( P = .137). Medial elbow joint space increases under a valgus load and then decreases when a maximal grip contraction is performed. This indicates that wrist and finger flexor muscle contraction may assist in limiting medial elbow joint space, a result similar to findings of previous research in vitro. Muscle activation of the upper extremity limits the medial elbow joint space, suggesting that injury prevention programs for throwing athletes should incorporate exercises for the elbow, wrist, and hand to limit excessive medial elbow joint space gapping during activities that create high valgus load.

  19. Joint-Specific Play Controller for Upper Extremity Therapy: Feasibility Study in Children With Wrist Impairment

    PubMed Central

    Wilkins, Megan M.; Basseches, Benjamin; Schwartz, Joel B.; Kerman, Karen; Trask, Christine; Brideau, Holly; Crisco, Joseph J.

    2016-01-01

    Background Challenges with any therapeutic program for children include the level of the child's engagement or adherence. Capitalizing on one of the primary learning avenues of children, play, the approach described in this article is to develop therapeutic toy and game controllers that require specific and repetitive joint movements to trigger toy/game activation. Objective The goal of this study was to evaluate a specially designed wrist flexion and extension play controller in a cohort of children with upper extremity motor impairments (UEMIs). The aim was to understand the relationship among controller play activity, measures of wrist and forearm range of motion (ROM) and spasticity, and ratings of fun and difficulty. Design This was a cross-sectional study of 21 children (12 male, 9 female; 4–12 years of age) with UEMIs. Methods All children participated in a structured in-clinic play session during which measurements of spasticity and ROM were collected. The children were fitted with the controller and played with 2 toys and 2 computer games for 5 minutes each. Wrist flexion and extension motion during play was recorded and analyzed. In addition, children rated the fun and difficulty of play. Results Flexion and extension goal movements were repeatedly achieved by children during the play session at an average frequency of 0.27 Hz. At this frequency, 15 minutes of play per day would result in approximately 1,700 targeted joint motions per week. Play activity was associated with ROM measures, specifically supination, but toy perception ratings of enjoyment and difficulty were not correlated with clinical measures. Limitations The reported results may not be representative of children with more severe UEMIs. Conclusions These outcomes indicate that the therapeutic controllers elicited repetitive goal movements and were adaptable, enjoyable, and challenging for children of varying ages and UEMIs. PMID:27197824

  20. Comparison of shock transmission and forearm electromyography between experienced and recreational tennis players during backhand strokes.

    PubMed

    Wei, Shun-Hwa; Chiang, Jinn-Yen; Shiang, Tzyy-Yuang; Chang, Hsiao-Yun

    2006-03-01

    To test the hypothesis that recreational tennis players transmit more shock impact from the racket to the elbow joint than experienced tennis players during the backhand stroke. Also, to test whether recreational tennis players used higher electromyographic (EMG) activities in common wrist extensor and flexor around epicondylar region at follow-through phase. A repeated-measure, cross-sectional study. National College of Physical Education and Sports at Taipei, Taiwan. Twenty-four male tennis players with no abnormal forearm musculoskeletal injury participated in the study. According to performance level, subjects were categorized into 2 groups: experienced and recreational. Impact transmission and wrist extensor-flexor EMG for backhand acceleration, impact, and follow-through phases were recorded for each player. An independent t test with a significance level of 0.05 was used to examine mean differences of shock impact and EMG between the 2 test groups. One-way ANOVA associated with Tukey multiple comparisons was used to identify differences among different impact locations and EMG phases. Experienced athletes reduced the racket impact to the elbow joint by 89.2%, but recreational players reduced it by only 61.8%. The largest EMG differences were found in the follow-through phase (P<0.05). Experienced athletes showed that their extensor and flexor EMGs were at submaximal level for follow-through phase, whereas recreational players maintained their flexor and extensor EMGs at either supramaximal or maximal level. Our results support the hypothesis that recreational players transmit more shock impact from the racket to the elbow joint and use larger wrist flexor and extensor EMG activities at follow-through phase of the backhand stroke. Follow-through control is proposed as a critical factor for reduction of shock transmission. Clinicians or trainers should instruct beginners to quickly release their grip tightness after ball-to-racket impact to reduce shock impact transmission to the wrist and elbow.

  1. Joint-Specific Play Controller for Upper Extremity Therapy: Feasibility Study in Children With Wrist Impairment.

    PubMed

    Wilcox, Bethany J; Wilkins, Megan M; Basseches, Benjamin; Schwartz, Joel B; Kerman, Karen; Trask, Christine; Brideau, Holly; Crisco, Joseph J

    2016-11-01

    Challenges with any therapeutic program for children include the level of the child's engagement or adherence. Capitalizing on one of the primary learning avenues of children, play, the approach described in this article is to develop therapeutic toy and game controllers that require specific and repetitive joint movements to trigger toy/game activation. The goal of this study was to evaluate a specially designed wrist flexion and extension play controller in a cohort of children with upper extremity motor impairments (UEMIs). The aim was to understand the relationship among controller play activity, measures of wrist and forearm range of motion (ROM) and spasticity, and ratings of fun and difficulty. This was a cross-sectional study of 21 children (12 male, 9 female; 4-12 years of age) with UEMIs. All children participated in a structured in-clinic play session during which measurements of spasticity and ROM were collected. The children were fitted with the controller and played with 2 toys and 2 computer games for 5 minutes each. Wrist flexion and extension motion during play was recorded and analyzed. In addition, children rated the fun and difficulty of play. Flexion and extension goal movements were repeatedly achieved by children during the play session at an average frequency of 0.27 Hz. At this frequency, 15 minutes of play per day would result in approximately 1,700 targeted joint motions per week. Play activity was associated with ROM measures, specifically supination, but toy perception ratings of enjoyment and difficulty were not correlated with clinical measures. The reported results may not be representative of children with more severe UEMIs. These outcomes indicate that the therapeutic controllers elicited repetitive goal movements and were adaptable, enjoyable, and challenging for children of varying ages and UEMIs. © 2016 American Physical Therapy Association.

  2. Upper limb joint motion of two different user groups during manual wheelchair propulsion

    NASA Astrophysics Data System (ADS)

    Hwang, Seonhong; Kim, Seunghyeon; Son, Jongsang; Lee, Jinbok; Kim, Youngho

    2013-02-01

    Manual wheelchair users have a high risk of injury to the upper extremities. Recent studies have focused on kinematic and kinetic analyses of manual wheelchair propulsion in order to understand the physical demands on wheelchair users. The purpose of this study was to investigate upper limb joint motion by using a motion capture system and a dynamometer with two different groups of wheelchair users propelling their wheelchairs at different speeds under different load conditions. The variations in the contact time, release time, and linear velocity of the experienced group were all larger than they were in the novice group. The propulsion angles of the experienced users were larger than those of the novices under all conditions. The variances in the propulsion force (both radial and tangential) of the experienced users were larger than those of the novices. The shoulder joint moment had the largest variance with the conditions, followed by the wrist joint moment and the elbow joint moment. The variance of the maximum shoulder joint moment was over four times the variance of the maximum wrist joint moment and eight times the maximum elbow joint moment. The maximum joint moments increased significantly as the speed and load increased in both groups. Quick and significant manipulation ability based on environmental changes is considered an important factor in efficient propulsion. This efficiency was confirmed from the propulsion power results. Sophisticated strategies for efficient manual wheelchair propulsion could be understood by observation of the physical responses of each upper limb joint to changes in load and speed. We expect that the findings of this study will be utilized for designing a rehabilitation program to reduce injuries.

  3. Experience of Soviet Medicine in a Great Patriotic War, 1941-1945. Volume 16, Section 4.

    DTIC Science & Technology

    1980-10-22

    Rotor function in the elbow, wrist joint and in the fingers/pins. In spite of energetic treatment by physiotherapy and therapeutic gymnastics , remained...the radiocarpal and elbow joint is removed by therapeutic gymnastics . It is discharged after 84 days (4/11 1943) with a good anatomical and functional...military service, it returned home into Moscow. on the arrival into nosco knee joint did not fold. Injured person itself dealt by gymnastics and in a

  4. Predictive grade of ultrasound synovitis for diagnosing rheumatoid arthritis in clinical practice and the possible difference between patients with and without seropositivity.

    PubMed

    Minowa, Kentaro; Ogasawara, Michihiro; Murayama, Go; Gorai, Misa; Yamada, Yusuke; Nemoto, Takuya; Matsuki, Yuko; Sugisaki, Nagachika; Ando, Seiichiro; Kon, Takayuki; Tada, Kurisu; Matsushita, Masakazu; Yamaji, Ken; Tamura, Naoto; Takasaki, Yoshinari

    2016-01-01

    To determine the degree of contribution and the contributing factors of ultrasound in the diagnosis of rheumatoid arthritis (RA) in daily clinical practice and the predictive differences depending on seropositivity. We included 122 patients who presented with the main complaint of finger and/or wrist joint pain but for whom no definite diagnosis was reached or treatment strategy was provided. Ultrasound was performed on at least 22 joints (both wrist joints, proximal interphalangeal joint, and metacarpophalangeal joints), and patients were followed for ≥6 months. Factors contributing to RA diagnosis were determined and compared between seropositive and seronegative RA patients. RA was diagnosed in 52 of 122 patients, in whom the American College of Rheumatology/European League Against Rheumatism (ACR/EULAR) classification criteria (odds ratio [OR] = 4.74, P = 0.01) and gray scale (GS) grade of 3 (OR = 3.64, P = 0.04) for ≥ 1 joint were the contributing factors. In seropositive RA, the ACR/EULAR criteria (OR = 15.53, P < 0.001) and power Doppler (PD) ≥ 2 for ≥ 1 joint (OR = 10.48, P = 0.0048) were the contributing factors. In seronegative RA, PD ≥ 1 for ≥ 1 joint contributed the most (OR = 20.00, P = 0.0044), but the ACR/EULAR criteria did not contribute to RA diagnosis (P = 0.57). Ultrasound findings contributed to RA diagnosis in clinical practice. The contributing factors are different in the presence or absence of seropositivity, and ultrasound complementation was particularly useful in seronegative RA patients.

  5. Percutaneous fixation with Kirschner wires versus volar locking plate fixation in adults with dorsally displaced fracture of distal radius: randomised controlled trial.

    PubMed

    Costa, Matthew L; Achten, Juul; Parsons, Nick R; Rangan, Amar; Griffin, Damian; Tubeuf, Sandy; Lamb, Sarah E

    2014-08-05

    To compare the clinical effectiveness of Kirschner wire fixation with locking plate fixation for patients with a dorsally displaced fracture of the distal radius. A multicentre two arm parallel group assessor blind randomised controlled trial with 1:1 treatment allocation. 18 trauma centres in the United Kingdom. 461 adults with a dorsally displaced fracture of the distal radius within 3 cm of the radiocarpal joint that required surgical fixation. Patients were excluded if the surgeon thought that the surface of the wrist joint was so badly displaced it required open reduction. Kirschner wire fixation: wires are passed through the skin over the dorsal aspect of the distal radius and into the bone to hold the fracture in the correct anatomical position. Locking plate fixation: a locking plate is applied through an incision over the volar (palm) aspect of the wrist and secured to the bone with fixed angle locking screws. validated patient rated wrist evaluation (PRWE). This rates wrist function in two (equally weighted) sections concerning the patient's experience of pain and disability to give a score out of 100. disabilities of arm, shoulder, and hand (DASH) score, the EuroQol (EQ-5D), and complications related to the surgery. The baseline characteristics of the two groups were well balanced, and over 90% of patients completed follow-up. The wrist function of both groups of patients improved by 12 months. There was no clinically relevant difference in the patient rated wrist score at three, six, or 12 months (difference in favour of the plate group was -1.3, 95% confidence interval -4.5 to 1.8; P=0.40). Nor was there a clinically relevant difference in health related quality of life or the number of complications in each group. Contrary to the existing literature, and against the rapidly increasing use of locking plate fixation, this trial found no difference in functional outcome in patients with dorsally displaced fractures of the distal radius treated with Kirschner wires or volar locking plates. Kirschner wire fixation, however, is cheaper and quicker to perform. Current Controlled Trials ISCRTN 31379280. UKCRN 8956. © Costa et al 2014.

  6. Microalbuminuria is associated with limited joint mobility in type I diabetes mellitus.

    PubMed Central

    Montaña, E; Rozadilla, A; Nolla, J M; Gomez, N; Escofet, D R; Soler, J

    1995-01-01

    OBJECTIVE--To determine whether limited joint mobility (LJM) is associated with microalbuminuria in type I diabetes mellitus. METHODS--Joint mobility was measured in a control group of 63 healthy subjects and in 63 type I diabetic patients, older than 18 years (mean 31.7 years, range 18-57), recruited from the outpatient clinic of the Endocrine Unit. Patients with established diabetic nephropathy (proteinuria or increased creatinine) were excluded. Joint mobility was assessed qualitatively with the prayer manoeuvre and quantitatively by measuring the angles of maximal flexion and extension of the fifth and third metacarpophalangeal (MCP) joints and wrist. Diabetic retinopathy was assessed by direct ophthalmoscopy. Urinary albumin excretion (UAE) was determined in at least two 24 hour urine samples. RESULTS--Joint mobility was limited in diabetic patients compared with control subjects. Diabetic patients with LJM had longer duration of diabetes (12.1 (SD 6.4) years compared with 6.9 (5.7) years; p < 0.001). Joint mobility was limited in patients with retinopathy: prayer manoeuvre was positive in 96.4% of patients with retinopathy, but in only 40.0% of patients with no retinopathy (p < 0.001); mobility of MCP joints and wrist was limited in diabetic patients with retinopathy even when the longer duration of their diabetes was taken into consideration. Microalbuminuria, present in 11 patients (17.5%), was associated with LJM: prayer manoeuvre was positive in 90.9% of patients with microalbuminuria, but in only 57.4% of patients with normal UAE (p < 0.05). Maximal flexion of MCP joints was reduced in patients with microalbuminuria. Microalbuminuria, but not LJM, was associated with risk factors of cardiovascular disease. CONCLUSION--LJM is associated with microalbuminuria and retinopathy in type I diabetes. The association is independent of age and duration of diabetes. PMID:7668902

  7. Tendinitis

    MedlinePlus

    ... of a tendon. Tendinitis usually happens after repeated injury to an area such as the wrist or ankle. It causes pain and soreness around a joint. Some common forms of tendinitis are named after the sports that increase their risk. They include tennis elbow, ...

  8. [Instability of the distal radioulnar joint: Treatment options for ulnar lesions of the triangular fibrocartilage complex].

    PubMed

    Spies, C K; Prommersberger, K J; Langer, M; Müller, L P; Hahn, P; Unglaub, F

    2015-08-01

    Injuries of the triangular fibrocartilage complex (TFCC) may be fatal to the distal radioulnar joint (DRUJ). This structure is one of the crucial stabilizers and guarantees unrestricted pronosupination of the forearm. A systematic examination is mandatory to diagnose DRUJ instability reliably. A clinical examination in comparison to the contralateral side is obligatory. Plain radiographs are required to exclude osseous lesions or deformities. Computed tomography of both wrists in neutral, pronation and supination is necessary to verify DRUJ instability in ambiguous situations. Based on a systematic examination wrist and DRUJ arthroscopy identify lesions clearly. Injuries of the radioulnar ligaments which entail DRUJ instability, should be reconstructed preferably anatomically. Ulnar-sided TFCC lesions may often cause DRUJ instability. Osseous ligament avulsions are mostly treated osteosynthetically. Ligament tears may be refixated using anchor or transosseous sutures. Tendon transplants are necessary for an anatomical reconstruction in cases of irreparable ruptures.

  9. Further delineation of Nevo syndrome.

    PubMed Central

    al-Gazali, L I; Bakalinova, D; Varady, E; Scorer, J; Nork, M

    1997-01-01

    Nevo syndrome is an autosomal recessive syndrome characterised by prenatal overgrowth, joint laxity, kyphosis, wrist drop, spindle shaped fingers, and volar oedema. Four children from two families have been reported previously. We report two further children from two unrelated Arab families from two different tribes. Both presented at birth with hypotonia, joint laxity, kyphosis, wrist drop, spindle shaped fingers, and volar oedema. Both have delayed motor development at the ages of 2 years 10 months and 3 months respectively. Cognitive development is normal in one, and the other case appears to be developing normally at 3 months of age. One has, in addition, a wide spinal canal on MRI of the spine indicating some degree of dural ectasia. This report brings the total number of children reported with this syndrome to six from four families; three of these families are Arab. This indicates that the gene for this syndrome is probably commoner in Arabs than in other populations. Images PMID:9152832

  10. [Set-up, portals and normal exploration in wrist arthroscopy].

    PubMed

    Atzei, A; Luchetti, R; Sgarbossa, A; Carità, E; Llusà, M

    2006-11-01

    Arthroscopy is an accepted technique for evaluation of intra-articular pathology and treatment of a variety of disorders even in the wrist joint. Dedicated miniaturized instrumentation is needed along with a specific traction system. The external distraction alone (dry technique) allows for complete joint exploration and several type of arthroscopic surgery, avoiding annoying leaking in the subcutaneous tissues, though further distension of the articular pouches can be achieved by saline infusion (fluid distension or wet technique). Knowledge of surface anatomic landmarks and careful surgical technique are required for proper portal placement and in order to avoid injury to the numerous noble structures crossing nearby. Description of radio- and medio-carpal portals is provided along with the different bony, condral, synovial and ligamentous structures that can be visualised or treated through each portal. Surgeon can choose the most suitable portal for scope or instruments, according to specific needs for diagnostic or therapeutic purposes.

  11. [Set-up, portals and normal exploration in wrist arthroscopy.

    PubMed

    Atzei, A; Luchetti, R; Sgarbossa, A; Carità, E; Llusà, M

    2006-11-01

    Arthroscopy is an accepted technique for evaluation of intra-articular pathology and treatment of a variety of disorders even in the wrist joint. Dedicated miniaturized instrumentation is needed along with a specific traction system. The external distraction alone (dry technique) allows for complete joint exploration and several type of arthroscopic surgery, avoiding annoying leaking in the subcutaneous tissues, though further distension of the articular pouches can be achieved by saline infusion (fluid distension or wet technique). Knowledge of surface anatomic landmarks and careful surgical technique are required for proper portal placement and in order to avoid injury to the numerous noble structures crossing nearby. Description of radio- and medio-carpal portals is provided along with the different bony, condral, synovial and ligamentous structures that can be visualised or treated through each portal. Surgeon can choose the most suitable portal for scope or instruments, according to specific needs for diagnostic or therapeutic purposes.

  12. Development and evaluation of gas-pressurized elastic sleeves for extravehicular activity.

    PubMed

    Tanaka, Kunihiko; Tohnan, Momoka; Abe, Chikara; Iwata, Chihiro; Yamagata, Kenji; Tanaka, Masao; Tanaka, Nobuyuki; Morita, Hironobu

    2010-07-01

    In space, mobility of the current extravehicular activity space suit is limited due to the pressure differential between the inside and outside of the suit. We have previously demonstrated that an elastic glove increased mobility when compared with a non-elastic glove such as that found in the current suit. Extending this work, we hypothesized that an elastic sleeve would also have more mobility compared to a non-elastic sleeve, but a partially elastic sleeve, consisting of elastic joints sewn to non-elastic parts in low mobility areas, might generate similar mobility to a wholly elastic sleeve. The right arms of 10 volunteers were studied with wholly elastic, partially elastic, and non-elastic sleeves in a chamber pressure of -220 mmHg. Range of motion (ROM) of the wrist and electromyography (EMG) of the flexor carpi radialis muscle and the biceps brachii muscle during wrist and elbow flexion were measured. ROM of the wrist was similar among all the sleeves. However, EMG amplitudes during wrist flexion with both elastic sleeves were significantly smaller than that with the non-elastic sleeve. EMG amplitudes during 90 degrees of elbow flexion were also significantly smaller in both elastic sleeves. However, no significant difference in EMG amplitudes was observed between the two elastic sleeves (0.53 +/- 0.06, 0.56 +/- 0.07, 1.14 +/- 0.10 V for wholly elastic, partially elastic, and non-elastic sleeves, respectively). The mobility of elastic sleeves is better than that of a non-elastic sleeve. Elasticity over the joints is important; however the elasticity of the other parts does not appear to affect mobility.

  13. Effectiveness of intra-articular injection in wrist joints according to triamcinolone hexacetonide dose in rheumatoid arthritis: a randomized controlled double-blind study.

    PubMed

    Pereira, Daniele Freitas; Natour, Jamil; Machado, Natália Pereira; Furtado, Rita Nely Vilar

    2015-02-01

    The aim of this study was to compare the effectiveness in the medium term between low and high doses of triamcinolone hexacetonide used in intra-articular injection in medium-sized joints of rheumatoid arthritis (RA) patients. A randomized double-blind study was carried out in rheumatoid arthritis patients with wrist painful refractory synovitis. Sixty wrists were included and randomized to receive low dose (20 mg) or high dose (40 mg). The outcomes assessed in T0, T1, T4, T8, and T12 weeks were visual analog scale for pain and for swelling, chronic disease activity index, goniometry, simplified Stanford Health Assessment Questionnaire, and side effects. Baseline mean (standard deviation) values were pain visual analog scale of 6.1 (1.6) and 6.3 (1.7), P = 0.562; swelling visual analog scale of 5.9 and 6.4, P = 0.466; chronic disease activity index of 17.8 and 16.8, P = 0.366; and Health Assessment Questionnaire of 0.8 and 0.7, P = 0.238, in the high- and low-dose groups, respectively. Both groups improved pain and swelling assessed by the visual analog scale, P < 0.001, in the intragroup analysis. Chronic disease activity index, goniometry, and Health Assessment Questionnaire also improved equally over time in both groups in the intragroup analysis (P < 0.001, 0.001, and 0.002, respectively). No serious side effects were detected. High and low triamcinolone hexacetonide doses had good effectiveness in wrist-blinded intra-articular injection of rheumatoid arthritis patients, without statistical difference between them.

  14. Coordination of intrinsic and extrinsic hand muscle activity as a function of wrist joint angle during two-digit grasping.

    PubMed

    Johnston, Jamie A; Bobich, Lisa R; Santello, Marco

    2010-04-26

    Fingertip forces result from the activation of muscles that cross the wrist and muscles whose origins and insertions reside within the hand (extrinsic and intrinsic hand muscles, respectively). Thus, tasks that involve changes in wrist angle affect the moment arm and length, hence the force-producing capabilities, of extrinsic muscles only. If a grasping task requires the exertion of constant fingertip forces, the Central Nervous System (CNS) may respond to changes in wrist angle by modulating the neural drive to extrinsic or intrinsic muscles only or by co-activating both sets of muscles. To distinguish between these scenarios, we recorded electromyographic (EMG) activity of intrinsic and extrinsic muscles of the thumb and index finger as a function of wrist angle during a two-digit object hold task. We hypothesized that changes in wrist angle would elicit EMG amplitude modulation of the extrinsic and intrinsic hand muscles. In one experimental condition we asked subjects to exert the same digit forces at each wrist angle, whereas in a second condition subjects could choose digit forces for holding the object. EMG activity was significantly modulated in both extrinsic and intrinsic muscles as a function of wrist angle (both p<0.05) but only for the constant force condition. Furthermore, EMG modulation resulted from uniform scaling of EMG amplitude across all muscles. We conclude that the CNS controlled both extrinsic and intrinsic muscles as a muscle synergy. These findings are discussed within the theoretical frameworks of synergies and common neural input across motor nuclei of hand muscles. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

  15. Application of the Trio-Tri-Star Carpal Wrist for use in a Solar Array Tracking Mechanism for the Momentum-eXchange/Electrodynamic Reboost (MXER) Tether Concept

    NASA Technical Reports Server (NTRS)

    Robertson, Jeffrey

    2006-01-01

    This paper describes the application of the Trio-Tri-Star Carpal Wrist to the Momentum Exchange Electro-Dynamic Re-boost (MXER) tether, an advanced space transportation concept being developed by the In-Space Propulsion Technology Office at NASA s Marshall Space Flight Center in Huntsville, Alabama. Dr. Joseph Bonometti and Mr. Kirk Sorensen are the principal engineers. In the paper, a brief overview of the MXER concept is given, with an emphasis on the design problem that this wrist is designed to address. The Trio-Tri-Star Carpal Wrist, a three degree of freedom parallel manipulator, invented by Dr. Stephen J. Canfield of Tennessee Tech University, is described with an overview of wrist geometry, kinematics, and stress analysis. A working model of the wrist was assembled at MSFC using Dr. Canfield s prototype to demonstrate its operation. Finally, a design description and supporting analysis of a MXER flight concept wrist is given, with recommendations for future development work.

  16. Quantitative evaluation of toothbrush and arm-joint motion during tooth brushing.

    PubMed

    Inada, Emi; Saitoh, Issei; Yu, Yong; Tomiyama, Daisuke; Murakami, Daisuke; Takemoto, Yoshihiko; Morizono, Ken; Iwasaki, Tomonori; Iwase, Yoko; Yamasaki, Youichi

    2015-07-01

    It is very difficult for dental professionals to objectively assess tooth brushing skill of patients, because an obvious index to assess the brushing motion of patients has not been established. The purpose of this study was to quantitatively evaluate toothbrush and arm-joint motion during tooth brushing. Tooth brushing motion, performed by dental hygienists for 15 s, was captured using a motion-capture system that continuously calculates the three-dimensional coordinates of object's motion relative to the floor. The dental hygienists performed the tooth brushing on the buccal and palatal sides of their right and left upper molars. The frequencies and power spectra of toothbrush motion and joint angles of the shoulder, elbow, and wrist were calculated and analyzed statistically. The frequency of toothbrush motion was higher on the left side (both buccal and palatal areas) than on the right side. There were no significant differences among joint angle frequencies within each brushing area. The inter- and intra-individual variations of the power spectrum of the elbow flexion angle when brushing were smaller than for any of the other angles. This study quantitatively confirmed that dental hygienists have individual distinctive rhythms during tooth brushing. All arm joints moved synchronously during brushing, and tooth brushing motion was controlled by coordinated movement of the joints. The elbow generated an individual's frequency through a stabilizing movement. The shoulder and wrist control the hand motion, and the elbow generates the cyclic rhythm during tooth brushing.

  17. Proximal and distal muscle fatigue differentially affect movement coordination

    PubMed Central

    Cowley, Jeffrey C.

    2017-01-01

    Muscle fatigue can cause people to change their movement patterns and these changes could contribute to acute or overuse injuries. However, these effects depend on which muscles are fatigued. The purpose of this study was to determine the differential effects of proximal and distal upper extremity muscle fatigue on repetitive movements. Fourteen subjects completed a repetitive ratcheting task before and after a fatigue protocol on separate days. The fatigue protocol either fatigued the proximal (shoulder flexor) or distal (finger flexor) muscles. Pre/Post changes in trunk, shoulder, elbow, and wrist kinematics were compared to determine how proximal and distal fatigue affected multi-joint movement patterns and variability. Proximal fatigue caused a significant increase (7°, p < 0.005) in trunk lean and velocity, reduced humeral elevation (11°, p < 0.005), and increased elbow flexion (4°, p < 0.01). In contrast, distal fatigue caused small but significant changes in trunk angles (2°, p < 0.05), increased velocity of wrench movement relative to the hand (17°/s, p < 0.001), and earlier wrist extension (4%, p < 0.005). Movement variability increased at proximal joints but not distal joints after both fatigue protocols (p < 0.05). Varying movements at proximal joints may help people adapt to fatigue at either proximal or distal joints. The identified differences between proximal and distal muscle fatigue adaptations could facilitate risk assessment of occupational tasks. PMID:28235005

  18. [Past, present and future of vascularised bone transfers in the hand and wrist].

    PubMed

    Allieu, Y

    2010-12-01

    The author specifies the aims and indications for simple or compound pedicle or free vascularised bone and bone and joint grafts (VBGs and VBJGs). He relates the history of VBGs whose indications for the wrist are often many and varied for the treatment of scaphoid non-union and Kienböch's disease. Within the hand the indication for compound VBGs is dominated by thumb reconstruction (skin and bone grafts). Compound VBGs and VBJGs used in an emergency for hand trauma, harvested from another irrecoverable long finger (bank finger) are extremely varied and adapted to each particular case. For secondary joint reconstruction in the adult, VBJGs must be discussed along with prosthetic arthroplasties (radio-carpal, lower radio-ulnar, trapezo-metacarpal, interphalangeal). For children VBJGs with an included growth plate maintain their indication. The immediate future of VBGs is that of a better knowledge of bone necrosis and bone innervation as well as an improvement in surgical techniques: microsurgery and robotics, mini-invasive surgery (wrist arthroscopy). The near future for VBGs is to control bone consolidation thanks to progress in the bio-engineering of bone tissue, which may make them obsolete and, for VBJGs, vascularised joint allografts, thanks to progress in immunosuppressant treatments. Although the immediate future and this near future may be envisaged according to the current advances, the same is not true for the distant future which remains totally unforeseeable, although this might involve regeneration and construction of organs by man himself. Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  19. Intelligent Robotic Systems Study (IRSS), phase 2

    NASA Technical Reports Server (NTRS)

    1990-01-01

    Under the Intelligent Robotics System Study (IRSS) contract, a generalized robotic control architecture was developed for use with the ProtoFlight Manipulator Arm (PFMA). The controller built for the PFMA provides localized position based force control, teleoperation and advanced path recording and playback capabilities. Various hand controllers can be used with the system in conjunction with a synthetic time delay capability to provide a realistic test bed for typical satellite servicing tasks. The configuration of the IRSS system is illustrated and discussed. The PFMA has six computer controllable degrees of freedom (DOF) plus a seventh manually indexable DOF, making the manipulator a pseudo 7 DOF mechanism. Because the PFMA was not developed to operate in a gravity field, but rather in space, it is counter balanced at the shoulder, elbow and wrist and a spring counterbalance has been added near the wrist to provide additional support. Built with long slender intra-joint linkages, the PFMA has a workspace nearly 2 meters deep and possesses sufficient dexterity to perform numerous satellite servicing tasks. The manipulator is arranged in a shoulder-yaw, pitch, elbow-pitch, and wrist-pitch, yaw, roll configuration, with an indexable shoulder roll joint. Digital control of the PFMA is implemented using a variety of single board computers developed by Heurikon Corporation and other manufacturers. The IRSS controller is designed to be a multi-rate, multi-tasking system. Independent joint servos run at a 134 Hz rate and position based impedance control functions at 67 Hz. Autonomous path generation and hand controller inputs are processed at a 33 Hz.

  20. Biomechanical loading on the upper extremity increases from single key tapping to directional tapping.

    PubMed

    Qin, Jin; Trudeau, Matthieu; Katz, Jeffrey N; Buchholz, Bryan; Dennerlein, Jack T

    2011-08-01

    Musculoskeletal disorders associated with computer use span the joints of the upper extremity. Computing typically involves tapping in multiple directions. Thus, we sought to describe the loading on the finger, wrist, elbow and shoulder joints in terms of kinematic and kinetic difference across single key switch tapping to directional tapping on multiple keys. An experiment with repeated measures design was conducted. Six subjects tapped with their right index finger on a stand-alone number keypad placed horizontally in three conditions: (1) on single key switch (the number key 5); (2) left and right on number key 4 and 6; (3) top and bottom on number key 8 and 2. A force-torque transducer underneath the keypad measured the fingertip force. An active-marker infrared motion analysis system measured the kinematics of the fingertip, hand, forearm, upper arm and torso. Joint moments for the metacarpophalangeal, wrist, elbow, and shoulder joints were estimated using inverse dynamics. Tapping in the top-bottom orientation introduced the largest biomechanical loading on the upper extremity especially for the proximal joint, followed by tapping in the left-right orientation, and the lowest loading was observed during single key switch tapping. Directional tapping on average increased the fingertip force, joint excursion, and peak-to-peak joint torque by 45%, 190% and 55%, respectively. Identifying the biomechanical loading patterns associated with these fundamental movements of keying improves the understanding of the risks of upper extremity musculoskeletal disorders for computer keyboard users. Copyright © 2010 Elsevier Ltd. All rights reserved.

  1. Bony ankylosis of the facet joint of the cervical spine in rheumatoid arthritis: Its characteristics and relationship to the clinical findings.

    PubMed

    Iizuka, Haku; Iizuka, Yoichi; Okamura, Koichi; Yonemoto, Yukio; Mieda, Tokue; Takagishi, Kenji

    2017-09-01

    The purpose of this study was to clarify the characteristics of bony ankylosis of the facet joint of the cervical spine in rheumatoid arthritis (RA) patients who required cervical spine surgery, and its relationship to the clinical findings. Eighty consecutive RA patients with cervical spine disorder who received initial surgery were reviewed. The occurrence of bony ankylosis of the facet joint of the cervical spine was investigated using computed tomography (CT) before surgery. We also evaluated the severity of neurological symptoms and the plain wrist radiographs taken before surgery; furthermore, we evaluated each patient's medical history for total knee arthroplasty (TKA) or hip arthroplasty (THA). The preoperative CT imaging demonstrated bony ankylosis of the facet joint of the cervical spine in 45 facet levels of 19 cases (BA + group). In all patients, responsible instability or stenosis was demonstrated just caudal or on the cranial side of those bony ankylosis. Before surgery, the BA + group included significantly more patients showing severe cervical myelopathy (p < 0.05), and significantly more cases showing progressed ankylosis in the wrist joint bilaterally (p < 0.01). There were also significantly more patients who received two or more TKA or THA before the cervical spine surgery in the BA + group (p < 0.01). Bony ankylosis of the facet joint of the cervical spine may be a risk factor of instability or stenosis at the adjacent disc level and severe cervical myelopathy. Furthermore, its ankylosis was demonstrated in RA patients with severe destroyed joints.

  2. Analysis of kinematic, kinetic and electromyographic patterns during root canal preparation with rotary and manual instruments.

    PubMed

    Pasternak, Braulio; Sousa Neto, Manoel Damião de; Dionísio, Valdeci Carlos; Pécora, Jesus Djalma; Silva, Ricardo Gariba

    2012-02-01

    This study assessed the muscular activity during root canal preparation through kinematics, kinetics, and electromyography (EMG). The operators prepared one canal with RaCe rotary instruments and another with Flexo-files. The kinematics of the major joints was reconstructed using an optoelectronic system and electromyographic responses of the flexor carpi radialis, extensor carpi radialis, brachioradialis, biceps brachii, triceps brachii, middle deltoid, and upper trapezius were recorded. The joint torques of the shoulder, elbow and wrist were calculated using inverse dynamics. In the kinematic analysis, angular movements of the wrist and elbow were classified as low risk factors for work-related musculoskeletal disorders. With respect to the shoulder, the classification was medium-risk. There was no significant difference revealed by the kinetic reports. The EMG results showed that for the middle deltoid and upper trapezius the rotary instrumentation elicited higher values. The flexor carpi radialis and extensor carpi radialis, as well as the brachioradialis showed a higher value with the manual method. The muscular recruitment for accomplishment of articular movements for root canal preparation with either the rotary or manual techniques is distinct. Nevertheless, the rotary instrument presented less difficulty in the generation of the joint torque in each articulation, thus, presenting a greater uniformity of joint torques.

  3. Analysis of kinematic, kinetic and electromyographic patterns during root canal preparation with rotary and manual instruments

    PubMed Central

    PASTERNAK-JÚNIOR, Braulio; de SOUSA NETO, Manoel Damião; DIONÍSIO, Valdeci Carlos; PÉCORA, Jesus Djalma; SILVA, Ricardo Gariba

    2012-01-01

    Objective This study assessed the muscular activity during root canal preparation through kinematics, kinetics, and electromyography (EMG). Material and Methods The operators prepared one canal with RaCe rotary instruments and another with Flexo-files. The kinematics of the major joints was reconstructed using an optoelectronic system and electromyographic responses of the flexor carpi radialis, extensor carpi radialis, brachioradialis, biceps brachii, triceps brachii, middle deltoid, and upper trapezius were recorded. The joint torques of the shoulder, elbow and wrist were calculated using inverse dynamics. In the kinematic analysis, angular movements of the wrist and elbow were classified as low risk factors for work-related musculoskeletal disorders. With respect to the shoulder, the classification was medium-risk. Results There was no significant difference revealed by the kinetic reports. The EMG results showed that for the middle deltoid and upper trapezius the rotary instrumentation elicited higher values. The flexor carpi radialis and extensor carpi radialis, as well as the brachioradialis showed a higher value with the manual method. Conclusion The muscular recruitment for accomplishment of articular movements for root canal preparation with either the rotary or manual techniques is distinct. Nevertheless, the rotary instrument presented less difficulty in the generation of the joint torque in each articulation, thus, presenting a greater uniformity of joint torques. PMID:22437679

  4. Wrist range of motion and motion frequency during toy and game play with a joint-specific controller specially designed to provide neuromuscular therapy: A proof of concept study in typically developing children.

    PubMed

    Crisco, Joseph J; Schwartz, Joel B; Wilcox, Bethany; Brideau, Holly; Basseches, Benjamin; Kerman, Karen

    2015-08-20

    Upper extremities affected by hemiplegic cerebral palsy (CP) and other neuromuscular disorders have been demonstrated to benefit from therapy, and the greater the duration of the therapy, the greater the benefit. A great motivator for participating in and extending the duration of therapy with children is play. Our focus is on active motion therapy of the wrist and forearm. In this study we examine the wrist motions associated with playing with two toys and three computer games controlled by a specially-designed play controller. Twenty children (ages 5-11) with no diagnosis of a muscular disorder were recruited. The play controller was fitted to the wrist and forearm of each child and used to measure and log wrist flexion and extension. Play activity and enjoyment were quantified by average wrist range of motion (ROM), motion frequency measures, and a discrete visual scale. We found significant differences in the average wrist ROM and motion frequency among the toys and games, yet there were no differences in the level of enjoyment across all toys and games, which was high. These findings indicate which toys and games may elicit the greater number of goal-directed movements, and lay the foundation for our long-term goal to develop and evaluate innovative motion-specific play controllers that are engaging rehabilitative devices for enhancing therapy and promoting neural plasticity and functional recovery in children with CP. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Cable compliance

    NASA Technical Reports Server (NTRS)

    Kerley, J.; Eklund, W.; Burkhardt, R.; Rossoni, P.

    1992-01-01

    The object of the investigation was to solve mechanical problems using cable-in-bending and cable-in-torsion. These problems included robotic contacts, targets, and controls using cable compliance. Studies continued in the use of cable compliance for the handicapped and the elderly. These included work stations, walkers, prosthetic knee joints, elbow joints, and wrist joints. More than half of these objects were met, and models were made and studies completed on most of the others. It was concluded that the many different and versatile solutions obtained only opened the door to many future challenges.

  6. Are the yips a task-specific dystonia or "golfer's cramp"?

    PubMed

    Adler, Charles H; Crews, Debra; Kahol, Kanav; Santello, Marco; Noble, Brie; Hentz, Joseph G; Caviness, John N

    2011-09-01

    This study compared golfers with and without the yips using joint movement and surface electromyographic detectors. Fifty golfers (25 with and 25 without complaints of the yips) were studied while putting. All putts were videotaped. Surface electromyography assessed arm cocontraction. A CyberGlove II (Immersion Technologies, Palo Alto, CA) assessed right-arm angular movements. Primary analysis was done by subjective complaint of the yips, whereas secondary analysis was done by video evidence of an involuntary movement. When grouped by subjective complaints, there were no differences in any movement parameter. When grouped by video evidence of an involuntary movement, yips cases had more (P < 0.001) angular movement in wrist pronation/supination and a trend (P = 0.08) for wrist flexor/extensor cocontraction (yips: 7 of 17, 41.2%; no yips: 6 of 33, 18.2%). Golfers with video evidence of an involuntary movement while putting have excessive rotation of the right wrist in a pronation/supination motion and, as previously reported, a trend for wrist flexor/extensor cocontraction. Copyright © 2011 Movement Disorder Society.

  7. Persistent ulnar-sided wrist pain after treatment of triquetral dorsal chip fracture: six cases related to triangular fibrocartilage complex injury.

    PubMed

    Lee, Seoung-joon; Rathod, Chasanal Mohan; Park, Kwang-Won; Hwang, Jin-Ho

    2012-05-01

    Persistent ulnar-sided wrist pain after treatment of triquetral dorsal chip fracture even after union is a matter of concern. There could be various reasons for this persistent pain like arthritis, instability, fractures and non-union. We correlate our findings of physical examination and wrist arthroscopy as triangular fibrocartilage complex injury to be one of the causes of this persistent pain. Six subjects who had persistent ulnocarpal joint pain and tenderness after triquetral dorsal chip fracture, despite 2 months of conservative treatment, were subjected to physical tests. If the physical examination yields positive results, then magnetic resonance imaging followed by arthroscopic treatment was performed. The six patients were then evaluated using the visual analogue scale, the Mayo modified wrist score, and the grip strength test. Triangular fibrocartilage complex (TFCC) injury was observed in all six cases and partial TFCC resection and synovectomy were performed. Analysis of the visual analogue scale, Mayo modified wrist score, and grip strength test data revealed statistically significant improvements (P < 0.05). In addition to several causes reported in the published literature, TFCC injury can be a cause of persistent ulnar pain after treatment of triquetral dorsal chip fracture. Arthroscopic partial TFCC resection can be considered to be a suitable treatment for such cases.

  8. A new design concept for wrist arthroplasty.

    PubMed

    Shepherd, D E T; Johnstone, A

    2005-01-01

    The wrist joint is frequently affected by arthritis, which leads to pain, loss of function and ultimately deformity. Various designs of wrist arthroplasty have been introduced to attempt to relieve pain and provide a functional range of motion. The first generation of wrist implant was a one-piece silicone elastomer. Later generations have designs that have two parts that articulate against each other. However, wrist implants have not achieved the same clinical success to date, compared with hip and knee implants, and there is a high revision rate associated with them. This paper describes a new design concept for wrist arthroplasty, based around the idea of combining the principles of an articulating implant with that of a flexible elastomer implant. The design consists of assembling a radial, carpal/metacarpal, plate and flexible parts together. The radial and carpal/metacarpal parts are to be made from ultra high molecular weight polyethylene. The bearing surfaces of the radial and carpal/metacarpal parts articulate against the flat surfaces of the plate, made from cobalt chrome molybdenum alloy. The radius on the bearing surface of the radial part enables flexion/extension, while the radius on the carpal/metacarpal surface enables radial/ulnar deviation. The articulation of the carpal/metacarpal part against the plate also allows for rotation as well as flexion/extension. The flexible part, made from Elast-Eon, which is a silicone polyurethane elastomer, is inserted through the hole of the plate and into the holes of the radial and carpal/metacarpal parts.

  9. Hand and Wrist Injuries in Elite Boxing: A Longitudinal Prospective Study (2005-2012) of the Great Britain Olympic Boxing Squad.

    PubMed

    Loosemore, Michael; Lightfoot, Joseph; Gatt, Ian; Hayton, Mike; Beardsley, Chris

    2017-03-01

    Background: The purpose of this investigation was to explore prospectively the nature and duration of hand and wrist injuries in training and competition in the Great Britain (GB) amateur boxing squad between 2005 and 2012. Methods: Longitudinal prospective injury surveillance of the GB boxing squad was performed from 2005 to 2012. The location, region affected, description, and the duration of each injury were recorded by the team doctor and team physiotherapist. We recorded whether the injury occurred during competition or training and also whether it was a new or a recurrent injury. The injury rate during competition was calculated as the number of injuries per 1000 hours. Results: Finger carpometacarpal instability and finger metacarpophalangeal joint extensor hood and capsule sprain also known as "boxer's knuckle" injuries were significantly more common than other injury diagnoses. The number of injuries during training or competition was similar, which is remarkable given the far greater number of training hours than competition hours performed. Injury rate for hand and wrist injuries in competition was 347 injuries per 1000 hours, while the estimated injury rate in training was <0.5 injuries per 1000 hours. Conclusion: Carpometacarpal instability and boxer's knuckle were more common than any other kind of hand and wrist injury in this cohort of elite amateur boxers. The rate of hand and wrist injuries was higher in competition than in training. Our study highlights the importance of hand and wrist injury prevention in the competition environment.

  10. Long-Term Clinical Outcome After Titanium Lunate Arthroplasty for Kienböck Disease.

    PubMed

    Viljakka, Timo; Tallroth, Kaj; Vastamäki, Martti

    2018-04-09

    Titanium lunate arthroplasty (TLA) for Kienböck disease was introduced in 1984 to address the silicone-wear particle problem common to silicone lunate implants. We sought to study the outcome of TLA. We identified 11 patients from our hospital database who had undergone TLA between 2001 and 2010. We evaluated pain, range of motion (ROM), function, and radiological outcome at a mean 11 years after surgery. We compared preoperative ROM and radiological findings with final follow-up in the ipsilateral wrist and also made comparisons with the contralateral wrists. No implants were removed, and no wrist joints were fused. Pain on the visual analog scale averaged 0.5 at rest, 0.3 at night, and 2.7 during heavy exertion. Seven patients had no pain at rest and 9 had no pain at night. Range of motion reached 70% of that of the contralateral wrist, and strength reached 81%. The Disabilities of the Arm, Shoulder, and Hand (DASH) score averaged 9.6, optional DASH 9.7, and Mayo wrist score 67.7. Radiologically, only Ståhl and arthrosis indexes differed significantly between affected and unaffected wrists. Two patients had a dorsally dislocated implant, meaning that around 20% of our cases probably meet the criteria for failure. The longer-term results of TLA for stage III Kienböck disease are promising. Therapeutic IV. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  11. Compensatory motor control after stroke: an alternative joint strategy for object-dependent shaping of hand posture.

    PubMed

    Raghavan, Preeti; Santello, Marco; Gordon, Andrew M; Krakauer, John W

    2010-06-01

    Efficient grasping requires planned and accurate coordination of finger movements to approximate the shape of an object before contact. In healthy subjects, hand shaping is known to occur early in reach under predominantly feedforward control. In patients with hemiparesis after stroke, execution of coordinated digit motion during grasping is impaired as a result of damage to the corticospinal tract. The question addressed here is whether patients with hemiparesis are able to compensate for their execution deficit with a qualitatively different grasp strategy that still allows them to differentiate hand posture to object shape. Subjects grasped a rectangular, concave, and convex object while wearing an instrumented glove. Reach-to-grasp was divided into three phases based on wrist kinematics: reach acceleration (reach onset to peak horizontal wrist velocity), reach deceleration (peak horizontal wrist velocity to reach offset), and grasp (reach offset to lift-off). Patients showed reduced finger abduction, proximal interphalangeal joint (PIP) flexion, and metacarpophalangeal joint (MCP) extension at object grasp across all three shapes compared with controls; however, they were able to partially differentiate hand posture for the convex and concave shapes using a compensatory strategy that involved increased MCP flexion rather than the PIP flexion seen in controls. Interestingly, shape-specific hand postures did not unfold initially during reach acceleration as seen in controls, but instead evolved later during reach deceleration, which suggests increased reliance on sensory feedback. These results indicate that kinematic analysis can identify and quantify within-limb compensatory motor control strategies after stroke. From a clinical perspective, quantitative study of compensation is important to better understand the process of recovery from brain injury. From a motor control perspective, compensation can be considered a model for how joint redundancy is exploited to accomplish the task goal through redistribution of work across effectors.

  12. Relative ratios of collagen composition of periarticular tissue of joints of the upper limb.

    PubMed

    Cheah, A; Harris, A; Le, W; Huang, Y; Yao, J

    2017-07-01

    We investigated the relative ratios of collagen composition of periarticular tissue of the elbow, wrist, metacarpophalangeal, proximal and distal interphalangeal joints. Periarticulat tissue, which we defined as the ligaments, palmar plate and capsule, was harvested from ten fresh-frozen cadaveric upper limbs, yielding 50 samples. The mean paired differences (95% confidence interval) of the relative ratios of collagen between the five different joints were estimated using mRNA expression of collagen in the periarticular tissue. We found that the relative collagen composition of the elbow was not significantly different to that of the proximal interphalangeal joint, nor between the proximal interphalangeal joint and distal interphalangeal joint, whereas the differences in collagen composition between all the other paired comparisons of the joints had confidence intervals that did not include zero.

  13. Motor impairments related to brain injury timing in early hemiparesis. Part II: abnormal upper extremity joint torque synergies.

    PubMed

    Sukal-Moulton, Theresa; Krosschell, Kristin J; Gaebler-Spira, Deborah J; Dewald, Julius P A

    2014-01-01

    Extensive neuromotor development occurs early in human life, and the timing of brain injury may affect the resulting motor impairment. In Part I of this series, it was demonstrated that the distribution of weakness in the upper extremity depended on the timing of brain injury in individuals with childhood-onset hemiparesis. The goal of this study was to characterize how timing of brain injury affects joint torque synergies, or losses of independent joint control. Twenty-four individuals with hemiparesis were divided into 3 groups based on the timing of their injury: before birth (PRE-natal, n = 8), around the time of birth (PERI-natal, n = 8), and after 6 months of age (POST-natal, n = 8). Individuals with hemiparesis and 8 typically developing peers participated in maximal isometric shoulder, elbow, wrist, and finger torque generation tasks while their efforts were recorded by a multiple degree-of-freedom load cell. Motor output in 4 joints of the upper extremity was concurrently measured during 8 primary torque generation tasks to quantify joint torque synergies. There were a number of significant coupling patterns identified in individuals with hemiparesis that differed from the typically developing group. POST-natal differences were most noted in the coupling of shoulder abductors with elbow, wrist, and finger flexors, while the PRE-natal group demonstrated significant distal joint coupling with elbow flexion. The torque synergies measured provide indirect evidence for the use of bulbospinal pathways in the POST-natal group, while those with earlier injury may use relatively preserved ipsilateral corticospinal motor pathways.

  14. Upper Limb Posture Estimation in Robotic and Virtual Reality-Based Rehabilitation

    PubMed Central

    Cortés, Camilo; Ardanza, Aitor; Molina-Rueda, F.; Cuesta-Gómez, A.; Ruiz, Oscar E.

    2014-01-01

    New motor rehabilitation therapies include virtual reality (VR) and robotic technologies. In limb rehabilitation, limb posture is required to (1) provide a limb realistic representation in VR games and (2) assess the patient improvement. When exoskeleton devices are used in the therapy, the measurements of their joint angles cannot be directly used to represent the posture of the patient limb, since the human and exoskeleton kinematic models differ. In response to this shortcoming, we propose a method to estimate the posture of the human limb attached to the exoskeleton. We use the exoskeleton joint angles measurements and the constraints of the exoskeleton on the limb to estimate the human limb joints angles. This paper presents (a) the mathematical formulation and solution to the problem, (b) the implementation of the proposed solution on a commercial exoskeleton system for the upper limb rehabilitation, (c) its integration into a rehabilitation VR game platform, and (d) the quantitative assessment of the method during elbow and wrist analytic training. Results show that this method properly estimates the limb posture to (i) animate avatars that represent the patient in VR games and (ii) obtain kinematic data for the patient assessment during elbow and wrist analytic rehabilitation. PMID:25110698

  15. Design and Kinematic Evaluation of a Novel Joint-Specific Play Controller: Application for Wrist and Forearm Therapy

    PubMed Central

    Schwartz, Joel B.; Wilcox, Bethany; Costa, Laura; Kerman, Karen

    2015-01-01

    Background The wrist extensors and flexors are profoundly affected in most children with hemiparetic cerebral palsy (CP) and are the major target of physical therapists' and occupational therapists' efforts to restore useful hand functions. A limitation of any therapeutic or exercise program can be the level of the child's engagement or adherence. The proposed approach capitalizes on the primary learning avenue for children: toy play. Objective This study aimed to develop and evaluate the measurement accuracy of innovative, motion-specific play controllers that are engaging rehabilitative devices for enhancing therapy and promoting neural plasticity and functional recovery in children with CP. Design Design objectives of the play controller included a cost-effective, home-based supplement to physical therapy, the ability to calibrate the controller so that play can be accomplished with any active range of motion, and the capability of logging play activity and wrist motion over week-long periods. Methods Accuracy of the play controller in measuring wrist flexion-extension was evaluated in 6 children who were developing in a typical manner, using optical motion capture of the wrist and forearm as the gold standard. Results The error of the play controller was estimated at approximately 5 degrees in both maximum wrist flexion and extension. Limitations Measurements were taken during a laboratory session, with children without CP, and no toy or computer game was interfaced with the play controller. Therefore, the potential engagement of the proposed approach for therapy remains to be evaluated. Conclusions This study presented the concept, development, and wrist tracking accuracy of an inexpensive approach to extremity therapy that may have a health benefit for children with hemiparesis, and potentially for patients of any age with a wide range of extremity neuromotor impairments. PMID:25573759

  16. Validation of the Leap Motion Controller using markered motion capture technology.

    PubMed

    Smeragliuolo, Anna H; Hill, N Jeremy; Disla, Luis; Putrino, David

    2016-06-14

    The Leap Motion Controller (LMC) is a low-cost, markerless motion capture device that tracks hand, wrist and forearm position. Integration of this technology into healthcare applications has begun to occur rapidly, making validation of the LMC׳s data output an important research goal. Here, we perform a detailed evaluation of the kinematic data output from the LMC, and validate this output against gold-standard, markered motion capture technology. We instructed subjects to perform three clinically-relevant wrist (flexion/extension, radial/ulnar deviation) and forearm (pronation/supination) movements. The movements were simultaneously tracked using both the LMC and a marker-based motion capture system from Motion Analysis Corporation (MAC). Adjusting for known inconsistencies in the LMC sampling frequency, we compared simultaneously acquired LMC and MAC data by performing Pearson׳s correlation (r) and root mean square error (RMSE). Wrist flexion/extension and radial/ulnar deviation showed good overall agreement (r=0.95; RMSE=11.6°, and r=0.92; RMSE=12.4°, respectively) with the MAC system. However, when tracking forearm pronation/supination, there were serious inconsistencies in reported joint angles (r=0.79; RMSE=38.4°). Hand posture significantly influenced the quality of wrist deviation (P<0.005) and forearm supination/pronation (P<0.001), but not wrist flexion/extension (P=0.29). We conclude that the LMC is capable of providing data that are clinically meaningful for wrist flexion/extension, and perhaps wrist deviation. It cannot yet return clinically meaningful data for measuring forearm pronation/supination. Future studies should continue to validate the LMC as updated versions of their software are developed. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Development and morphogenesis of human wrist joint during embryonic and early fetal period

    PubMed Central

    Hita-Contreras, Fidel; Martínez-Amat, Antonio; Ortiz, Raúl; Caba, Octavio; Álvarez, Pablo; Prados, José C; Lomas-Vega, Rafael; Aránega, Antonia; Sánchez-Montesinos, Indalecio; Mérida-Velasco, Juan A

    2012-01-01

    The development of the human wrist joint has been studied widely, with the main focus on carpal chondrogenesis, ligaments and triangular fibrocartilage. However, there are some discrepancies concerning the origin and morphogenetic time-table of these structures, including nerves, muscles and vascular elements. For this study we used serial sections of 57 human embryonic (n = 30) and fetal (n = 27) specimens from O’Rahilly stages 17–23 and 9–14 weeks, respectively. The following phases in carpal morphogenesis have been established: undifferentiated mesenchyme (stage 17), condensated mesenchyme (stages 18 and 19), pre-chondrogenic (stages 19 and 20) and chondrogenic (stages 21 and over). Carpal chondrification and osteogenic processes are similar, starting with capitate and hamate (stage 19) and ending with pisiform (stage 22). In week 14, a vascular bud penetrates into the lunate cartilaginous mold, early sign of the osteogenic process that will be completed after birth. In stage 18, median, ulnar and radial nerves and thenar eminence appear in the hand plate. In stage 21, there are indications of the interosseous muscles, and in stage 22 flexor digitorum superficialis, flexor digitorum profundus and lumbrical muscles, transverse carpal ligament and collateral ligaments emerge. In stage 23, the articular disc, radiocarpal and ulnocarpal ligaments and deep palmar arterial arch become visible. Radiate carpal and interosseous ligaments appear in week 9, and in week 10, dorsal radiocarpal ligament and articular capsule are evident. Finally, synovial membrane is observed in week 13. We have performed a complete analysis of the morphogenesis of the structures of the human wrist joint. Our results present new data on nervous and arterial elements and provide the basis for further investigations on anatomical pathology, comparative morphology and evolutionary anthropology. PMID:22428933

  18. Comparison of regression models for estimation of isometric wrist joint torques using surface electromyography

    PubMed Central

    2011-01-01

    Background Several regression models have been proposed for estimation of isometric joint torque using surface electromyography (SEMG) signals. Common issues related to torque estimation models are degradation of model accuracy with passage of time, electrode displacement, and alteration of limb posture. This work compares the performance of the most commonly used regression models under these circumstances, in order to assist researchers with identifying the most appropriate model for a specific biomedical application. Methods Eleven healthy volunteers participated in this study. A custom-built rig, equipped with a torque sensor, was used to measure isometric torque as each volunteer flexed and extended his wrist. SEMG signals from eight forearm muscles, in addition to wrist joint torque data were gathered during the experiment. Additional data were gathered one hour and twenty-four hours following the completion of the first data gathering session, for the purpose of evaluating the effects of passage of time and electrode displacement on accuracy of models. Acquired SEMG signals were filtered, rectified, normalized and then fed to models for training. Results It was shown that mean adjusted coefficient of determination (Ra2) values decrease between 20%-35% for different models after one hour while altering arm posture decreased mean Ra2 values between 64% to 74% for different models. Conclusions Model estimation accuracy drops significantly with passage of time, electrode displacement, and alteration of limb posture. Therefore model retraining is crucial for preserving estimation accuracy. Data resampling can significantly reduce model training time without losing estimation accuracy. Among the models compared, ordinary least squares linear regression model (OLS) was shown to have high isometric torque estimation accuracy combined with very short training times. PMID:21943179

  19. Success of ultrasound-guided versus landmark-guided arthrocentesis of hip, ankle, and wrist in a cadaver model.

    PubMed

    Berona, Kristin; Abdi, Amin; Menchine, Michael; Mailhot, Tom; Kang, Tarina; Seif, Dina; Chilstrom, Mikaela

    2017-02-01

    The objectives of this study were to evaluate emergency medicine resident-performed ultrasound for diagnosis of effusions, compare the success of a landmark-guided (LM) approach with an ultrasound-guided (US) technique for hip, ankle and wrist arthrocentesis, and compare change in provider confidence with LM and US arthrocentesis. After a brief video on LM and US arthrocentesis, residents were asked to identify artificially created effusions in the hip, ankle and wrist in a cadaver model and to perform US and LM arthrocentesis of the effusions. Outcomes included success of joint aspiration, time to aspiration, and number of attempts. Residents were surveyed regarding their confidence in identifying effusions with ultrasound and performing LM and US arthrocentesis. Eighteen residents completed the study. Sensitivity of ultrasound for detecting joint effusion was 86% and specificity was 90%. Residents were successful with ultrasound in 96% of attempts and with landmark 89% of attempts (p=0.257). Median number of attempts was 1 with ultrasound and 2 with landmarks (p=0.12). Median time to success with ultrasound was 38s and 51s with landmarks (p=0.23). After the session, confidence in both US and LM arthrocentesis improved significantly, however the post intervention confidence in US arthrocentesis was higher than LM (4.3 vs. 3.8, p<0.001). EM residents were able to successfully identify joint effusions with ultrasound, however we were unable to detect significant differences in actual procedural success between the two modalities. Further studies are needed to define the role of ultrasound for arthrocentesis in the emergency department. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Percutaneous fixation with Kirschner wires versus volar locking plate fixation in adults with dorsally displaced fracture of distal radius: randomised controlled trial

    PubMed Central

    Achten, Juul; Parsons, Nick R; Rangan, Amar; Griffin, Damian; Tubeuf, Sandy; Lamb, Sarah E

    2014-01-01

    Objectives To compare the clinical effectiveness of Kirschner wire fixation with locking plate fixation for patients with a dorsally displaced fracture of the distal radius. Design A multicentre two arm parallel group assessor blind randomised controlled trial with 1:1 treatment allocation. Setting 18 trauma centres in the United Kingdom. Participants 461 adults with a dorsally displaced fracture of the distal radius within 3 cm of the radiocarpal joint that required surgical fixation. Patients were excluded if the surgeon thought that the surface of the wrist joint was so badly displaced it required open reduction. Interventions Kirschner wire fixation: wires are passed through the skin over the dorsal aspect of the distal radius and into the bone to hold the fracture in the correct anatomical position. Locking plate fixation: a locking plate is applied through an incision over the volar (palm) aspect of the wrist and secured to the bone with fixed angle locking screws. Main outcome measures Primary outcome measure: validated patient rated wrist evaluation (PRWE). This rates wrist function in two (equally weighted) sections concerning the patient’s experience of pain and disability to give a score out of 100. Secondary outcomes: disabilities of arm, shoulder, and hand (DASH) score, the EuroQol (EQ-5D), and complications related to the surgery. Results The baseline characteristics of the two groups were well balanced, and over 90% of patients completed follow-up. The wrist function of both groups of patients improved by 12 months. There was no clinically relevant difference in the patient rated wrist score at three, six, or 12 months (difference in favour of the plate group was −1.3, 95% confidence interval −4.5 to 1.8; P=0.40). Nor was there a clinically relevant difference in health related quality of life or the number of complications in each group. Conclusions Contrary to the existing literature, and against the rapidly increasing use of locking plate fixation, this trial found no difference in functional outcome in patients with dorsally displaced fractures of the distal radius treated with Kirschner wires or volar locking plates. Kirschner wire fixation, however, is cheaper and quicker to perform. Trial registration Current Controlled Trials ISCRTN 31379280. UKCRN 8956. PMID:25096595

  1. Four-corner fusion of the wrist: clinical and radiographic outcome of 31 patients.

    PubMed

    Mavrogenis, Andreas F; Flevas, Dimitrios A; Raptis, Konstantinos; Megaloikonomos, Panayiotis D; Igoumenou, Vasilios G; Antoniadou, Thekla; Dimopoulos, Leonidas; Antonopoulos, Dimitrios; Spyridonos, Sarantis G

    2016-12-01

    Four-corner fusion is a rational surgical option for the management of degenerative conditions of the wrist. Most related studies have compared four-corner fusion with scaphoid excision or proximal row carpectomy, with a variety of reported results. To enhance the literature, we performed this study to evaluate a series of patients with degenerative conditions of the wrist treated with four-corner fusion using 3 surgical techniques and to discuss the clinical and radiographic outcome of the patients. We retrospectively studied 31 patients (24 men, 7 women; mean age, 43 years; 9 heavy manual laborers) who underwent four-corner fusion of their wrists for degenerative conditions from 2005 to 2015. Internal fixation was done using multiple Kirschner wires (14 patients), headless compressive screws (8 patients), or a circular plate (9 patients). Mean follow-up was 4 years (1-11 years). We evaluated the clinical outcome with the Patient-Rated Wrist Evaluation (PRWE) score and fusion with radiographs. All patients experienced improvement of their pain, function, range of motion and grip strength (p < 0.05). Twenty-three patients (74 %) reported no pain, and eight patients reported mild, occasional pain. Twenty-one patients (68 %) were able to do usual and specific activities. Mean wrist motion improved to 70 % and mean grip strength improved to 85 % of opposite wrist. Two heavy manual labor patients requested a job modification because of wrist impairment. Radiographs of the wrist showed fusion of all fused joints in 28 (90.3 %) patients and partial fusion in three patients (9.7 %). No patient with partial fusion required a reoperation for symptomatic nonunion until the period of this study. Three patients experienced complications (10 %). Two patients treated with a circular plate experienced complex regional pain syndrome and painful implant impingement; another patient treated with Kirschner wires and headless compression screws experienced radiolunate arthritis from impingement of the lunate screw to the radius. Four-corner fusion is a reliable limited wrist fusion technique that provides pain relief, grip strength and satisfactory range of motion in patients with degenerative conditions of the wrist. Partial union is more common with Kirschner wire fixation and complications are more common with circular plate fixation.

  2. Circuit For Control Of Electromechanical Prosthetic Hand

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr.

    1995-01-01

    Proposed circuit for control of electromechanical prosthetic hand derives electrical control signals from shoulder movements. Updated, electronic version of prosthesis, that includes two hooklike fingers actuated via cables from shoulder harness. Circuit built around favored shoulder harness, provides more dexterous movement, without incurring complexity of computer-controlled "bionic" or hydraulically actuated devices. Additional harness and potentiometer connected to similar control circuit mounted on other shoulder. Used to control stepping motor rotating hand about prosthetic wrist to one of number of angles consistent with number of digital outputs. Finger-control signals developed by circuit connected to first shoulder harness transmitted to prosthetic hand via sliprings at prosthetic wrist joint.

  3. System description document for the Anthrobot-2: A dexterous robot hand

    NASA Technical Reports Server (NTRS)

    Ali, Michael S.; Engler, Charles, Jr.

    1991-01-01

    The Anthrobot-2 is an anatomically correct, fully functioning robot hand. The number of fingers, the proportions of the links, the placement and motion of the thumb, and the shape of the palm follow those of the human hand. Each of the finger and thumb joints are servo-controlled. The Anthrobot-2 also includes a two-degree-of-freedom wrist. The entire package, including wrist, hand, and actuators, will mount on the ends of a variety of industrial manipulators. A patent has been applied for on the design. The Anthrobot-2 will be useful in tasks where dexterous manipulation or telemanipulation are required.

  4. Decoding complete reach and grasp actions from local primary motor cortex populations.

    PubMed

    Vargas-Irwin, Carlos E; Shakhnarovich, Gregory; Yadollahpour, Payman; Mislow, John M K; Black, Michael J; Donoghue, John P

    2010-07-21

    How the activity of populations of cortical neurons generates coordinated multijoint actions of the arm, wrist, and hand is poorly understood. This study combined multielectrode recording techniques with full arm motion capture to relate neural activity in primary motor cortex (M1) of macaques (Macaca mulatta) to arm, wrist, and hand postures during movement. We find that the firing rate of individual M1 neurons is typically modulated by the kinematics of multiple joints and that small, local ensembles of M1 neurons contain sufficient information to reconstruct 25 measured joint angles (representing an estimated 10 functionally independent degrees of freedom). Beyond showing that the spiking patterns of local M1 ensembles represent a rich set of naturalistic movements involving the entire upper limb, the results also suggest that achieving high-dimensional reach and grasp actions with neuroprosthetic devices may be possible using small intracortical arrays like those already being tested in human pilot clinical trials.

  5. The Search for, Recovery, and Positive Identification of a Vietnam-Era U.S. Army Soldier

    DTIC Science & Technology

    2010-02-01

    CriminalJustice, College at Brnckpon. SUNY Brockpon. NY 14420. tCeiilrül Identification Laboratory (CIL), Joint POW-MIA Accounting Ciimmand (JPAC...most consistent with Mongoloid ancestry during the subse- quent joint forensic review (JFR). which involved American and Vietnamese forensic experts...described by analysts as "unreliable" apparently because of his nervous behavior. One of the other four witnesses turned over a wrist- watch and a dog

  6. Robotic assessment of the contribution of motor commands to wrist position sense.

    PubMed

    Contu, Sara; Marini, Francesca; Masia, Lorenzo

    2017-07-01

    Assessing joint position sense for rehabilitation after neurological injury provides a prognostic factor in recovery and long-term functional outcomes. A common method for testing joint position sense involves the active replication of a joint configuration presented via a passive movement. However, recent evidence showed how this sense is mediated by the centrally generated signals of motor command, such that movements produced volitionally may be coded differently from passive movements and accuracy may be different when matching targets presented actively. To verify this hypothesis we asked ten participants to actively replicate a target wrist angle with the help of a visual feedback in two conditions, which differed in the mode of target presentation: active (aaJPM) or passive (paJPM). The accuracy of target matching, directional bias and variability were analyzed, as well as speed and smoothness of the matching movement and criterion movement in the aaJPM. Overall results indicate higher accuracy and lower variability in the paJPM, while directional bias showed the tendency to overshoot the target regardless of condition. The speed did not differ in the two conditions and movements were smoother in the aaJPM, suggesting a higher confidence by participants in their matching ability. In conclusion, this study suggests that motor commands negatively affect the accuracy of joint position sense when matching involves the integration of visual and proprioceptive information.

  7. Changes in Ultrasonographic Vascularity Upon Initiation of Adalimumab Combination Therapy in Rheumatoid Arthritis Patients With an Inadequate Response to Methotrexate

    PubMed Central

    Nishio, Midori J.; Goyal, Janak R.; MacCarter, Daryl K.; Wells, Alvin F.; Chen, Su; Kupper, Hartmut; Kalabic, Jasmina

    2016-01-01

    Objective To assess joint disease activity by ultrasound (US) in patients with rheumatoid arthritis (RA) initiating treatment with adalimumab (ADA) plus methotrexate (MTX). Methods Data for this post hoc analysis originated from the MUSICA trial (ClinicalTrials.gov identifier: NCT01185288), which evaluated the efficacy of initiating ADA (40 mg every other week) plus 7.5 or 20 mg/week MTX in 309 patients with RA with an inadequate response to MTX. Synovial vascularization over 24 weeks was assessed bilaterally at metacarpophalangeal joint 2 (MCP2), MCP3, MCP5, metatarsophalangeal joint 5, and the wrists by power Doppler US (PDUS). A semiquantitative 4‐grade scale was used. Disease activity was assessed using the Disease Activity Score in 28 joints using the C‐reactive protein level (DAS28‐CRP) and Simplified Disease Activity Index (SDAI). The correlation between continuous variables was assessed using Pearson's correlation coefficient. Results After 24 weeks of treatment with ADA plus MTX, rapid improvements in the mean synovial vascularity score were observed; the greatest improvements were in MCP2 (−0.5), MCP3 (−0.4), and the wrist (−0.4). At week 24, patients with the lowest DAS28‐CRP (<2.6) had the lowest mean 5‐joint and 3‐joint composite synovial vascularity scores. The 5‐joint and 3‐joint scores were strongly correlated (ρ > 0.9). Synovial vascularity scores correlated poorly with DAS28, swollen joint count in 66 joints (SJC66), SJC28, tender joint count in 68 joints (TJC68), TJC28, Clinical Disease Activity Index (CDAI), SDAI, physician's global assessment, patient's global assessment of pain, and disease duration (ρ < 0.2). Thirty‐two (70%) of 46 patients with a DAS28‐CRP of <2.6, and 11 (58%) of 19 patients with an SDAI indicating remission had at least 1 joint with a synovial vascularity score of ≥1. Conclusion PDUS detects changes in synovial vascularity in RA patients treated with ADA plus MTX, and residual synovial vascularity in patients in whom clinical disease control has been achieved. PMID:27214046

  8. Photography of the histological and radiological analysis of the ligaments of the distal radioulnar joint.

    PubMed

    Clayton, Gemma

    2013-06-01

    This project was undertaken as part of the PhD research project of Paul Malone, Pricipal Investigator, Covance plc, Harrogate. Mr Malone approached the photography department for involvement in the study with the aim of settling the current debate on the anatomical and histological features of the distal radioulnar ligaments by capturing the anatomy photographically throughout the process of dissection via a microtome. The author was approached to lead on the photographic protocol as part of her post-graduate certificate training at Staffordshire University. High-resolution digital images of an entire human arm were required, the main area of interest being the distal radioulnar joint of the wrist. Images were to be taken at 40 μm intervals as the specimen was sliced. When microtomy was undertaken through the ligaments images were made at 20 μm intervals. A method of suspending a camera approximately 1 metre above the specimen was devised, together with the preparation for the capture, processing and storage of images. The resulting images were then to be subject to further analysis in the form of 3-Dimensional reconstruction, using computer modelling techniques and software. The possibility of merging the images with sequences obtained from both CT & MRI using image handling software is also an area of exploration, in collaboration with the University of Manchester's Visualisation Centre.

  9. A robot-aided visuo-motor training that improves proprioception and spatial accuracy of untrained movement.

    PubMed

    Elangovan, Naveen; Cappello, Leonardo; Masia, Lorenzo; Aman, Joshua; Konczak, Jürgen

    2017-12-06

    Proprioceptive function can become enhanced during motor learning. Yet, we have incomplete knowledge to what extent proprioceptive function is trainable and how a training that enhances proprioception may influence performance in untrained motor skills. To address this knowledge gap, healthy young adults (N = 14) trained in a visuomotor task that required learners to make increasingly accurate wrist movements. Using a robotic exoskeleton coupled with a virtual visual environment, participants tilted a virtual table through continuous wrist flexion/extension movements with the goal to position a rolling ball on table into a target. With learning progress, the level of difficulty increased by altering the virtual ball mechanics and the gain between joint movement and ball velocity. Before and after training, wrist position sense acuity and spatial movement accuracy in an untrained, discrete wrist-pointing task was assessed using the same robot. All participants showed evidence of proprioceptive-motor learning. Mean position sense discrimination threshold improved by 34%. Wrist movement accuracy in the untrained pointing task improved by 27% in 13/14 participants. This demonstrates that a short sensorimotor training challenging proprioception can a) effectively enhance proprioceptive acuity and b) improve the accuracy of untrained movement. These findings provide a scientific basis for applying such somatosensory-based motor training to clinical populations with known proprioceptive dysfunction to enhance sensorimotor performance.

  10. A study on the measurement of wrist motion range using the iPhone 4 gyroscope application.

    PubMed

    Kim, Tae Seob; Park, David Dae Hwan; Lee, Young Bae; Han, Dong Gil; Shim, Jeong Su; Lee, Young Jig; Kim, Peter Chan Woo

    2014-08-01

    Measuring the range of motion (ROM) of the wrist is an important physical examination conducted in the Department of Hand Surgery for the purpose of evaluation, diagnosis, prognosis, and treatment of patients. The most common method for performing this task is by using a universal goniometer. This study was performed using 52 healthy participants to compare wrist ROM measurement using a universal goniometer and the iPhone 4 Gyroscope application. Participants did not have previous wrist illnesses and their measured values for wrist motion were compared in each direction. Normal values for wrist ROM are 73 degrees of flexion, 71 degrees of extension, 19 degrees of radial deviation, 33 degrees of ulnar deviation, 140 degrees of supination, and 60 degrees of pronation.The average measurement values obtained using the goniometer were 74.2 (5.1) degrees for flexion, 71.1 (4.9) degrees for extension, 19.7 (3.0) degrees for radial deviation, 34.0 (3.7) degrees for ulnar deviation, 140.8 (5.6) degrees for supination, and 61.1 (4.7) degrees for pronation. The average measurement values obtained using the iPhone 4 Gyroscope application were 73.7 (5.5) degrees for flexion, 70.8 (5.1) degrees for extension, 19.5 (3.0) degrees for radial deviation, 33.7 (3.9) degrees for ulnar deviation, 140.4 (5.7) degrees for supination, and 60.8 (4.9) degrees for pronation. The differences between the measurement values by the Gyroscope application and average value were 0.7 degrees for flexion, -0.2 degrees for extension, 0.5 degrees for radial deviation, 0.7 degrees for ulnar deviation, 0.4 degrees for supination, and 0.8 degrees for pronation. The differences in average value were not statistically significant. The authors introduced a new method of measuring the range of wrist motion using the iPhone 4 Gyroscope application that is simpler to use and can be performed by the patient outside a clinical setting.

  11. Four-corner arthrodesis with a radiolucent locking dorsal circular plate: technique and outcomes.

    PubMed

    Rudnick, Benjamin; Goljan, Peter; Pruzansky, Jason S; Bachoura, Abdo; Jacoby, Sidney M; Rekant, Mark S

    2014-09-01

    Scaphoid excision and four-corner arthrodesis (FCA) is an acceptable motion sparing procedure used to treat wrist arthritis. Recently, a locking dorsal circular plate composed of polyether-ether-ketone has been introduced (Xpode®; TriMed Inc.). The purpose of this study is to assess the efficacy of this specific plate design with regard to FCA. A retrospective chart review of all patients who underwent FCA with an Xpode® between January 1, 2008 and December 31, 2012 was conducted. Patients were contacted and asked to return to clinic for clinical and radiographic follow-up. Patient demographics, range of motion, grip strength, and complications were collected from medical records. Patients completed a patient-rated wrist evaluation (PRWE). A paired t test was used to compare means, and p values <0.05 were considered statistically significant. Twenty-six procedures (24 patients) were identified. One patient required full wrist fusion following the initial procedure. Of the 25 remaining wrists, arthrodesis was successfully achieved in 20 (80 %). Eleven patients (13 wrists, 52 %) returned to clinic for an average follow-up of 28 months. Mean wrist extension improved from 30 to 47°, and flexion decreased from 33 to 23°. Average grip strength was 77 % of the uninjured side. The mean PRWE scores for pain and function were 19.7 and 17.1, respectively. Five patients underwent additional operations (two hardware removals, two contracture releases, and one distal radial ulnar joint arthroplasty). FCA with the Xpode® yielded reasonable results for pain and function and demonstrated a fusion rate of 80 %.

  12. Analysis of 41 suicide attempts by wrist cutting: a retrospective analysis.

    PubMed

    Ersen, B; Kahveci, R; Saki, M C; Tunali, O; Aksu, I

    2017-02-01

    Self-cutting injuries have a low mortality rate, but this type of injuries has special clinical significance because they have the potential of leading to devastating disability and repeated suicide attempts. The purpose of this study is to analyze the nature and outcomes of wrist-cutting injuries. A retrospective study was designed in order to investigate 41 suicide attempts by wrist cutting attended to Uludag University Faculty of Medicine Emergency Department between June 2008 and December 2014. The patients were analyzed for age, gender, alcohol intake, psychological state, prior suicide attempts, and clinical features such as injury side, injury pattern, and used tool. It was seen that the severity of wrist-cutting injury variates between gender and age. Alcohol or drug consumption and having a diagnosed psychiatric disorder create a higher risk for extensive wrist lacerations. It was seen that skin only lacerations were most likely to repeat the act and therefore are most in need of psychiatric intervention. Level III, retrospective study.

  13. Arthroscopic Management of Scaphoid-Trapezium-Trapezoid Joint Arthritis.

    PubMed

    Pegoli, Loris; Pozzi, Alessandro

    2017-11-01

    Scaphoid-trapezium-trapezoid (STT) joint arthritis is a common condition consisting of pain on the radial side of the wrist and base of the thumb, swelling, and tenderness over the STT joint. Common symptoms are loss of grip strength and thumb function. There are several treatments, from symptomatic conservative treatment to surgical solutions, such as arthrodesis, arthroplasties, and prosthesis implant. The role of arthroscopy has grown and is probably the best treatment of this condition. Advantages of arthroscopic management of STT arthritis are faster recovery, better view of the joint during surgery, and possibility of creating less damage to the capsular and ligamentous structures. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Coactivation index of children with congenital upper limb reduction deficiencies before and after using a wrist-driven 3D printed partial hand prosthesis.

    PubMed

    Zuniga, Jorge M; Dimitrios, Katsavelis; Peck, Jean L; Srivastava, Rakesh; Pierce, James E; Dudley, Drew R; Salazar, David A; Young, Keaton J; Knarr, Brian A

    2018-06-08

    Co-contraction is the simultaneous activation of agonist and antagonist muscles that produces forces around a joint. It is unknown if the use of a wrist-driven 3D printed transitional prostheses has any influence on the neuromuscular motor control strategies of the affected hand of children with unilateral upper-limb reduction deficiencies. Thus, the purpose of the current investigation was to examine the coactivation index (CI) of children with congenital upper-limb reduction deficiencies before and after 6 months of using a wrist-driven 3D printed partial hand prosthesis. Electromyographic activity of wrist flexors and extensors (flexor carpi ulnaris and extensor digitorum) was recorded during maximal voluntary contraction of the affected and non-affected wrists. Co-contraction was calculated using the coactivation index and was expressed as percent activation of antagonist over agonist. Nine children (two girls and seven boys, 6 to 16 years of age) with congenital upper-limb deficiencies participated in this study and were fitted with a wrist-driven 3D printed prosthetic hand. From the nine children, five (two girls and three boys, 7 to 10 years of age) completed a second visit after using the wrist-driven 3D printed partial hand prosthesis for 6 months. Separate two-way repeated measures ANOVAs were performed to analyze the coactivation index and strength data. There was a significant main effect for hand with the affected hand resulting in a higher coactivation index for flexion and extension than the non-affected hand. For wrist flexion there was a significant main effect for time indicating that the affected and non-affected hand had a significantly lower coactivation index after a period of 6 months. The use of a wrist-driven 3D printed hand prosthesis lowered the coactivation index by 70% in children with congenital upper limb reduction deficiencies. This reduction in coactivation and possible improvement in motor control strategies can potentially improve prosthetic rehabilitation outcomes.

  15. Principal components of hand kinematics and neurophysiological signals in motor cortex during reach to grasp movements

    PubMed Central

    Aggarwal, Vikram; Thakor, Nitish V.; Schieber, Marc H.

    2014-01-01

    A few kinematic synergies identified by principal component analysis (PCA) account for most of the variance in the coordinated joint rotations of the fingers and wrist used for a wide variety of hand movements. To examine the possibility that motor cortex might control the hand through such synergies, we collected simultaneous kinematic and neurophysiological data from monkeys performing a reach-to-grasp task. We used PCA, jPCA and isomap to extract kinematic synergies from 18 joint angles in the fingers and wrist and analyzed the relationships of both single-unit and multiunit spike recordings, as well as local field potentials (LFPs), to these synergies. For most spike recordings, the maximal absolute cross-correlations of firing rates were somewhat stronger with an individual joint angle than with any principal component (PC), any jPC or any isomap dimension. In decoding analyses, where spikes and LFP power in the 100- to 170-Hz band each provided better decoding than other LFP-based signals, the first PC was decoded as well as the best decoded joint angle. But the remaining PCs and jPCs were predicted with lower accuracy than individual joint angles. Although PCs, jPCs or isomap dimensions might provide a more parsimonious description of kinematics, our findings indicate that the kinematic synergies identified with these techniques are not represented in motor cortex more strongly than the original joint angles. We suggest that the motor cortex might act to sculpt the synergies generated by subcortical centers, superimposing an ability to individuate finger movements and adapt the hand to grasp a wide variety of objects. PMID:24990564

  16. Quantitative power Doppler ultrasound measures of peripheral joint synovitis in poor prognosis early rheumatoid arthritis predict radiographic progression.

    PubMed

    Sreerangaiah, Dee; Grayer, Michael; Fisher, Benjamin A; Ho, Meilien; Abraham, Sonya; Taylor, Peter C

    2016-01-01

    To assess the value of quantitative vascular imaging by power Doppler US (PDUS) as a tool that can be used to stratify patient risk of joint damage in early seropositive RA while still biologic naive but on synthetic DMARD treatment. Eighty-five patients with seropositive RA of <3 years duration had clinical, laboratory and imaging assessments at 0 and 12 months. Imaging assessments consisted of radiographs of the hands and feet, two-dimensional (2D) high-frequency and PDUS imaging of 10 MCP joints that were scored for erosions and vascularity and three-dimensional (3D) PDUS of MCP joints and wrists that were scored for vascularity. Severe deterioration on radiographs and ultrasonography was seen in 45 and 28% of patients, respectively. The 3D power Doppler volume and 2D vascularity scores were the most useful US predictors of deterioration. These variables were modelled in two equations that estimate structural damage over 12 months. The equations had a sensitivity of 63.2% and specificity of 80.9% for predicting radiographic structural damage and a sensitivity of 54.2% and specificity of 96.7% for predicting structural damage on ultrasonography. In seropositive early RA, quantitative vascular imaging by PDUS has clinical utility in predicting which patients will derive benefit from early use of biologic therapy. © The Author 2015. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. A comparison of force sensing techniques for planetary manipulation

    NASA Technical Reports Server (NTRS)

    Helmick, Daniel; Okon, Avi; DiCicco, Matt

    2006-01-01

    Five techniques for sensing forces with a manipulator are compared analytically and experimentally. The techniques compared are: a six-axis wrist force/torque sensor, joint torque sensors, link strain gauges, motor current sensors, and flexibility modeling. The accuracy and repeatability fo each technique is quantified and compared.

  18. Effects on the Distal Radioulnar Joint of Ablation of Triangular Fibrocartilage Complex Tears With Radiofrequency Energy.

    PubMed

    Huber, Michaela; Loibl, Markus; Eder, Christoph; Kujat, Richard; Nerlich, Michael; Gehmert, Sebastian

    2016-11-01

    This cadaver study investigated the temperature profile in the wrist joint and distal radioulnar joint (DRUJ) during radiofrequency energy (RFE) application for triangular fibrocartilage complex resection. An arthroscopic partial resection of the triangular fibrocartilage complex using monopolar and bipolar RFE was simulated in 14 cadaver limbs. The temperature was recorded simultaneously in the DRUJ and at 6 other anatomic locations of the wrist during RFE application. The mean temperature in the DRUJ was 43.3 ± 8.2°C for the bipolar system in the ablation mode (60 W) and 30.4 ± 3.4°C for the monopolar system in the cut mode (20 W) after 30 seconds. The highest measured temperature in the DRUJ was 54.3°C for the bipolar system and 68.1°C for the monopolar system. The application of RFE for debridement or resection of the triangular fibrocartilage complex in a clinical setting can induce peak temperatures that might cause damage to the cartilage of the DRUJ. Bipolar systems produce higher mean temperatures than monopolar devices. RFE application increases the mean temperature in the DRUJ after 30 seconds to a level that may jeopardize cartilage tissue. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  19. MRI of the wrist in juvenile idiopathic arthritis: proposal of a paediatric synovitis score by a consensus of an international working group. Results of a multicentre reliability study.

    PubMed

    Damasio, Maria Beatrice; Malattia, Clara; Tanturri de Horatio, Laura; Mattiuz, Chiara; Pistorio, Angela; Bracaglia, Claudia; Barbuti, Domenico; Boavida, Peter; Juhan, Karen Lambot; Ording, Lil Sophie Mueller; Rosendahl, Karen; Martini, Alberto; Magnano, GianMichele; Tomà, Paolo

    2012-09-01

    MRI is a sensitive tool for the evaluation of synovitis in juvenile idiopathic arthritis (JIA). The purpose of this study was to introduce a novel MRI-based score for synovitis in children and to examine its inter- and intraobserver variability in a multi-centre study. Wrist MRI was performed in 76 children with JIA. On postcontrast 3-D spoiled gradient-echo and fat-suppressed T2-weighted spin-echo images, joint recesses were scored for the degree of synovial enhancement, effusion and overall inflammation independently by two paediatric radiologists. Total-enhancement and inflammation-synovitis scores were calculated. Interobserver agreement was poor to moderate for enhancement and inflammation in all recesses, except in the radioulnar and radiocarpal joints. Intraobserver agreement was good to excellent. For enhancement and inflammation scores, mean differences (95 % CI) between observers were -1.18 (-4.79 to 2.42) and -2.11 (-6.06 to 1.83). Intraobserver variability (reader 1) was 0 (-1.65 to 1.65) and 0.02 (-1.39 to 1.44). Intraobserver agreement was good. Except for the radioulnar and radiocarpal joints, interobserver agreement was not acceptable. Therefore, the proposed scoring system requires further refinement.

  20. Mechanical design of EFW Exo II: A hybrid exoskeleton for elbow-forearm-wrist rehabilitation.

    PubMed

    Bian, Hui; Chen, Ziye; Wang, Hao; Zhao, Tieshi

    2017-07-01

    The use of rehabilitation exoskeleton has become an important means for the treatment of stroke patients. A hybrid exoskeleton named EFW Exo II is developed for the motor function rehabilitation of elbow, forearm and wrist. The EFW Exo II is based on a parallel 2-URR/RRS mechanism and a serial R mechanism. It could fit both left and right arms for the symmetrical and open structure, and the distance between the elbow and wrist could automatically adjust for different forearm length. Details of the mechanical design are introduced. Brushless DC servo motors with planetary gear reducer are used as the actuators of the exoskeleton. Gear drive and belt drive are used for power transmission. A three dimensional force sensor is mounted in the handle to regulate the interaction between the exoskeleton and patient. The EFW Exo II can realize rehabilitation exercise for each joint and the ranges of motion meet the rehabilitation demands of daily living.

  1. Influence of Input Hardware and Work Surface Angle on Upper Limb Posture in a Hybrid Computer Workstation.

    PubMed

    Kingston, David C; Riddell, Maureen F; McKinnon, Colin D; Gallagher, Kaitlin M; Callaghan, Jack P

    2016-02-01

    We evaluated the effect of work surface angle and input hardware on upper-limb posture when using a hybrid computer workstation. Offices use sit-stand and/or tablet workstations to increase worker mobility. These workstations may have negative effects on upper-limb joints by increasing time spent in non-neutral postures, but a hybrid standing workstation may improve working postures. Fourteen participants completed office tasks in four workstation configurations: a horizontal or sloped 15° working surface with computer or tablet hardware. Three-dimensional right upper-limb postures were recorded during three tasks: reading, form filling, and writing e-mails. Amplitude probability distribution functions determined the median and range of upper-limb postures. The sloped-surface tablet workstation decreased wrist ulnar deviation by 5° when compared to the horizontal-surface computer when reading. When using computer input devices (keyboard and mouse), the shoulder, elbow, and wrist were closest to neutral joint postures when working on a horizontal work surface. The elbow was 23° and 15° more extended, whereas the wrist was 6° less ulnar deviated, when reading compared to typing forms or e-mails. We recommend that the horizontal-surface computer configuration be used for typing and the sloped-surface tablet configuration be used for intermittent reading tasks in this hybrid workstation. Offices with mobile employees could use this workstation for alternating their upper-extremity postures; however, other aspects of the device need further investigation. © 2015, Human Factors and Ergonomics Society.

  2. Incidence and Risk Factors for Volar Wrist Ganglia in the U.S. Military and Civilian Populations.

    PubMed

    Balazs, George C; Dworak, Theodora C; Tropf, Jordan; Nanos, George P; Tintle, Scott M

    2016-11-01

    To identify the incidence and demographic factors associated with volar wrist ganglia in both military and civilian beneficiary populations. The U.S. Department of Defense Management Analysis and Reporting Tool (M2) accesses a comprehensive database of all health care visits by military personnel and their dependents. Because there is no specific code for ganglions of the wrist, the database was searched for all military personnel and civilian beneficiaries with an International Classification of Diseases, 9th Revision, diagnosis of 727.41 (ganglion of a joint) or 727.43 (ganglion, unspecified location) between 2009 and 2014. Two random samples of 1000 patients were selected from both the military and the civilian beneficiary cohorts, and their electronic medical records were examined to identify those with volar wrist ganglia. The proportion of volar wrist ganglia was then applied to the overall population data to estimate the total incidence with a 95% confidence interval and 5% margin of error. Unadjusted incidence rates and adjusted incidence rate ratios were determined using Poisson regression, controlling for age, sex, branch of military service, and military seniority. The unadjusted incidence of volar wrist ganglia is 3.72 per 10,000 person-years (0.04%/y) in female civilian beneficiaries, 1.04 per 10,000 person-years (0.01%/y) in male civilian beneficiaries, 7.98 per 10,000 person-years (0.08%/y) in female military personnel, and 3.73 per 10,000 person-years (0.04%/y) in male military personnel. When controlled for age, military personnel have a 2.5-times increased rate of volar wrist ganglia, and women have a 2.3-times increased rate. In the military cohort, female sex, branch of service, and seniority were significantly associated with the diagnosis of a volar wrist ganglion when controlled for age. In the civilian beneficiary cohort, only female sex was significant. Military service members have higher rates of volar wrist ganglia diagnoses than their age- and sex-matched civilian counterparts. Women are significantly more likely to be diagnosed with a volar wrist ganglion, regardless of age or military status. The epidemiology of volar wrist ganglia is poorly defined, and few studies have firmly defined demographic factors associated with the diagnosis. We provide the overall incidence rate of the diagnosis and report a significant association with female sex even when controlled for age. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  3. Reliability and concurrent validity of a new iPhone® goniometric application for measuring active wrist range of motion: a cross-sectional study in asymptomatic subjects.

    PubMed

    Pourahmadi, Mohammad Reza; Ebrahimi Takamjani, Ismail; Sarrafzadeh, Javad; Bahramian, Mehrdad; Mohseni-Bandpei, Mohammad Ali; Rajabzadeh, Fatemeh; Taghipour, Morteza

    2017-03-01

    Measurement of wrist range of motion (ROM) is often considered to be an essential component of wrist physical examination. The measurement can be carried out through various instruments such as goniometers and inclinometers. Recent smartphones have been equipped with accelerometers and magnetometers, which, through specific software applications (apps) can be used for goniometric functions. This study, for the first time, aimed to evaluate the reliability and concurrent validity of a new smartphone goniometric app (Goniometer Pro©) for measuring active wrist ROM. In all, 120 wrists of 70 asymptomatic adults (38 men and 32 women; aged 18-40 years) were assessed in a physiotherapy clinic located at the School of Rehabilitation Sciences, Iran University of Medical Science and Health Services, Tehran, Iran. Following the recruitment process, active wrist ROM was measured using a universal goniometer and iPhone ® 5 app. Two blinded examiners each utilized the universal goniometer and iPhone ® to measure active wrist ROM using a volar/dorsal alignment technique in the following sequences: flexion, extension, radial deviation, and ulnar deviation. The second (2 h later) and third (48 h later) sessions were carried out in the same manner as the first session. All the measurements were conducted three times and the mean value of three repetitions for each measurement was used for analysis. Intraclass correlation coefficient (ICC) models (3, k) and (2, k) were used to determine the intra-rater and inter-rater reliability, respectively. The Pearson correlation coefficients were used to establish concurrent validity of the iPhone ® app. Good to excellent intra-rater and inter-rater reliability was demonstrated for the goniometer with ICC values of ≥ 0.82 and ≥ 0.73 and the iPhone ® app with ICC values of ≥ 0.83 and ≥ 0.79, respectively. Minimum detectable change at the 95% confidence level (MDC 95 ) was computed as 1.96 × standard error of measurement × √2. The MDC 95 ranged from 1.66° to 5.35° for the intra-rater analysis and from 1.97° to 6.15° for the inter-rater analysis. The concurrent validity between the two instruments was high, with r values of ≥ 0.80. From the results of this cross-sectional study, it can be concluded that the iPhone ® app possesses good to excellent intra-rater and inter-rater reliability and concurrent validity. It seems that this app can be used for the measurement of wrist ROM. However, further research is needed to evaluate symptomatic subjects using this app. © 2016 Anatomical Society.

  4. A practical guide for performing arthrography under fluoroscopic or ultrasound guidance.

    PubMed

    Lungu, Eugen; Moser, Thomas P

    2015-12-01

    We propose a practical approach for performing arthrography with fluoroscopic or ultrasound guidance. Different approaches to the principal joints of the upper limb (shoulder, elbow, wrist and fingers), lower limb (hip, knee, ankle and foot) as well as the facet joints of the spine are discussed and illustrated with numerous drawings. Whenever possible, we emphasise the concept of targeting articular recesses, which offers many advantages over traditional techniques aiming at the joint space. • Arthrography remains a foremost technique in musculoskeletal radiology • Most joints can be successfully accessed by targeting the articular recess • Targeting the recess offers several advantages over traditional approaches • Ultrasound-guidance is now favoured over fluoroscopy and targeting the recess is equally applicable.

  5. Camera-tracking gaming control device for evaluation of active wrist flexion and extension.

    PubMed

    Shefer Eini, Dalit; Ratzon, Navah Z; Rizzo, Albert A; Yeh, Shih-Ching; Lange, Belinda; Yaffe, Batia; Daich, Alexander; Weiss, Patrice L; Kizony, Rachel

    Cross sectional. Measuring wrist range of motion (ROM) is an essential procedure in hand therapy clinics. To test the reliability and validity of a dynamic ROM assessment, the Camera Wrist Tracker (CWT). Wrist flexion and extension ROM of 15 patients with distal radius fractures and 15 matched controls were assessed with the CWT and with a universal goniometer. One-way model intraclass correlation coefficient analysis indicated high test-retest reliability for extension (ICC = 0.92) and moderate reliability for flexion (ICC = 0.49). Standard error for extension was 2.45° and for flexion was 4.07°. Repeated-measures analysis revealed a significant main effect for group; ROM was greater in the control group (F[1, 28] = 47.35; P < .001). The concurrent validity of the CWT was partially supported. The results indicate that the CWT may provide highly reliable scores for dynamic wrist extension ROM, and moderately reliable scores for flexion, in people recovering from a distal radius fracture. N/A. Copyright © 2016 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  6. Upper limb joint muscle/tendon injury and anthropometric adaptations in French competitive tennis players.

    PubMed

    Rogowski, Isabelle; Creveaux, Thomas; Genevois, Cyril; Klouche, Shahnaz; Rahme, Michel; Hardy, Philippe

    2016-01-01

    The purpose of this study was to examine the relationship between the upper limb anthropometric dimensions and a history of dominant upper limb injury in tennis players. Dominant and non-dominant wrist, forearm, elbow and arm circumferences, along with a history of dominant upper limb injuries, were assessed in 147 male and female players, assigned to four groups based on location of injury: wrist (n = 9), elbow (n = 25), shoulder (n = 14) and healthy players (n = 99). From anthropometric dimensions, bilateral differences in circumferences and in proportions were calculated. The wrist group presented a significant bilateral difference in arm circumference, and asymmetrical bilateral proportions between wrist and forearm, as well as between elbow and arm, compared to the healthy group (6.6 ± 3.1% vs. 4.9 ± 4.0%, P < 0.01; -3.6 ± 3.0% vs. -0.9 ± 2.9%, P < 0.05; and -2.2 ± 2.2% vs. 0.1 ± 3.4%, P < 0.05, respectively). The elbow group displayed asymmetrical bilateral proportions between forearm and arm compared to the healthy group (-0.4 ± 4.3% vs. 1.5 ± 4.0%, P < 0.01). The shoulder group showed significant bilateral difference in elbow circumference, and asymmetrical bilateral proportions between forearm and elbow when compared to the healthy group (5.8 ± 4.7% vs. 3.1 ± 4.8%, P < 0.05 and -1.7 ± 4.5% vs. 1.4 ± 4.3%, P < 0.01, respectively). These findings suggest that players with a history of injury at the upper limb joint present altered dominant upper limb proportions in comparison with the non-dominant side, and such asymmetrical proportions would appear to be specific to the location of injury. Further studies are needed to confirm the link between location of tennis injury and asymmetry in upper limb proportions using high-tech measurements in symptomatic tennis players.

  7. 3-T direct MR arthrography of the wrist: value of finger trap distraction to assess intrinsic ligament and triangular fibrocartilage complex tears.

    PubMed

    Cerny, Milena; Marlois, Romain; Theumann, Nicolas; Bollmann, Christof; Wehrli, Laurent; Richarme, Delphine; Meuli, Reto; Becce, Fabio

    2013-10-01

    To determine the value of applying finger trap distraction during direct MR arthrography of the wrist to assess intrinsic ligament and triangular fibrocartilage complex (TFCC) tears. Twenty consecutive patients were prospectively investigated by three-compartment wrist MR arthrography. Imaging was performed with 3-T scanners using a three-dimensional isotropic (0.4 mm) T1-weighted gradient-recalled echo sequence, with and without finger trap distraction (4 kg). In a blind and independent fashion, two musculoskeletal radiologists measured the width of the scapholunate (SL), lunotriquetral (LT) and ulna-TFC (UTFC) joint spaces. They evaluated the amount of contrast medium within these spaces using a four-point scale, and assessed SL, LT and TFCC tears, as well as the disruption of Gilula's carpal arcs. With finger trap distraction, both readers found a significant increase in width of the SL space (mean Δ = +0.1mm, p ≤ 0.040), and noticed more contrast medium therein (p ≤ 0.035). In contrast, the differences in width of the LT (mean Δ = +0.1 mm, p ≥ 0.057) and UTFC (mean Δ = 0mm, p ≥ 0.728) spaces, as well as the amount of contrast material within these spaces were not statistically significant (p = 0.607 and ≥ 0.157, respectively). Both readers detected more SL (Δ = +1, p = 0.157) and LT (Δ = +2, p = 0.223) tears, although statistical significance was not reached, and Gilula's carpal arcs were more frequently disrupted during finger trap distraction (Δ = +5, p = 0.025). The application of finger trap distraction during direct wrist MR arthrography may enhance both detection and characterisation of SL and LT ligament tears by widening the SL space and increasing the amount of contrast within the SL and LT joint spaces. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  8. Proximal-distal differences in movement smoothness reflect differences in biomechanics.

    PubMed

    Salmond, Layne H; Davidson, Andrew D; Charles, Steven K

    2017-03-01

    Smoothness is a hallmark of healthy movement. Past research indicates that smoothness may be a side product of a control strategy that minimizes error. However, this is not the only reason for smooth movements. Our musculoskeletal system itself contributes to movement smoothness: the mechanical impedance (inertia, damping, and stiffness) of our limbs and joints resists sudden change, resulting in a natural smoothing effect. How the biomechanics and neural control interact to result in an observed level of smoothness is not clear. The purpose of this study is to 1 ) characterize the smoothness of wrist rotations, 2 ) compare it with the smoothness of planar shoulder-elbow (reaching) movements, and 3 ) determine the cause of observed differences in smoothness. Ten healthy subjects performed wrist and reaching movements involving different targets, directions, and speeds. We found wrist movements to be significantly less smooth than reaching movements and to vary in smoothness with movement direction. To identify the causes underlying these observations, we tested a number of hypotheses involving differences in bandwidth, signal-dependent noise, speed, impedance anisotropy, and movement duration. Our simulations revealed that proximal-distal differences in smoothness reflect proximal-distal differences in biomechanics: the greater impedance of the shoulder-elbow filters neural noise more than the wrist. In contrast, differences in signal-dependent noise and speed were not sufficiently large to recreate the observed differences in smoothness. We also found that the variation in wrist movement smoothness with direction appear to be caused by, or at least correlated with, differences in movement duration, not impedance anisotropy. NEW & NOTEWORTHY This article presents the first thorough characterization of the smoothness of wrist rotations (flexion-extension and radial-ulnar deviation) and comparison with the smoothness of reaching (shoulder-elbow) movements. We found wrist rotations to be significantly less smooth than reaching movements and determined that this difference reflects proximal-distal differences in biomechanics: the greater impedance (inertia, damping, stiffness) of the shoulder-elbow filters noise in the command signal more than the impedance of the wrist. Copyright © 2017 the American Physiological Society.

  9. Electromyography of wrist and finger flexor muscles in olive baboons (Papio anubis).

    PubMed

    Patel, Biren A; Larson, Susan G; Stern, Jack T

    2012-01-01

    Some non-human primates use digitigrade hand postures when walking slowly on the ground. As a component of an extended limb, a digitigrade posture can help minimize wrist joint moments thereby requiring little force production directly from wrist flexors (and/or from the assistance of finger flexors) to maintain limb posture. As a consequence, less active muscle volume would be required from these anti-gravity muscles and overall metabolic costs associated with locomotion could be reduced. To investigate whether the use of digitigrade hand postures during walking in primates entails minimal use of anti-gravity muscles, this study examined electromyography (EMG) patterns in both the wrist and finger flexor muscles in facultatively digitigrade olive baboons (Papio anubis) across a range of speeds. The results demonstrate that baboons can adopt a digitigrade hand posture when standing and moving at slow speeds without requiring substantial EMG activity from distal anti-gravity muscles. Higher speed locomotion, however, entails increasing EMG activity and is accompanied by a dynamic shift to a more palmigrade-like limb posture. Thus, the ability to adopt a digitigrade hand posture by monkeys is an adaptation for ground living, but it was never co-opted for fast locomotion. Rather, digitigrady in primates appears to be related to energetic efficiency for walking long distances.

  10. The role of proprioception and neuromuscular stability in carpal instabilities.

    PubMed

    Hagert, E; Lluch, A; Rein, S

    2016-01-01

    Carpal stability has traditionally been defined as dependent on the articular congruity of joint surfaces, the static stability maintained by intact ligaments, and the dynamic stability caused by muscle contractions resulting in a compression of joint surfaces. In the past decade, a fourth factor in carpal stability has been proposed, involving the neuromuscular and proprioceptive control of joints. The proprioception of the wrist originates from afferent signals elicited by sensory end organs (mechanoreceptors) in ligaments and joint capsules that elicit spinal reflexes for immediate joint stability, as well as higher order neuromuscular influx to the cerebellum and sensorimotor cortices for planning and executing joint control. The aim of this review is to provide an understanding of the role of proprioception and neuromuscular control in carpal instabilities by delineating the sensory innervation and the neuromuscular control of the carpus, as well as descriptions of clinical applications of proprioception in carpal instabilities. © The Author(s) 2015.

  11. Robotic Arm Manipulator Using Active Control for Sample Acquisition and Transfer, and Passive Mode for Surface Compliance

    NASA Technical Reports Server (NTRS)

    Liu, Jun; Underhill, Michael L.; Trease, Brian P.; Lindemann, Randel A.

    2010-01-01

    A robotic arm that consists of three joints with four degrees of freedom (DOF) has been developed. It can carry an end-effector to acquire and transfer samples by using active control and comply with surface topology in a passive mode during a brief surface contact. The three joints are arranged in such a way that one joint of two DOFs is located at the shoulder, one joint of one DOF is located at the elbow, and one joint of one DOF is located at the wrist. Operationally, three DOFs are moved in the same plane, and the remaining one on the shoulder is moved perpendicular to the other three for better compliance with ground surface and more flexibility of sample handling. Three out of four joints are backdriveable, making the mechanism less complex and more cost effective

  12. Control of joint motion simulators for biomechanical research

    NASA Technical Reports Server (NTRS)

    Colbaugh, R.; Glass, K.

    1992-01-01

    The authors present a hierarchical adaptive algorithm for controlling upper extremity human joint motion simulators. A joint motion simulator is a computer-controlled, electromechanical system which permits the application of forces to the tendons of a human cadaver specimen in such a way that the cadaver joint under study achieves a desired motion in a physiologic manner. The proposed control scheme does not require knowledge of the cadaver specimen dynamic model, and solves on-line the indeterminate problem which arises because human joints typically possess more actuators than degrees of freedom. Computer simulation results are given for an elbow/forearm system and wrist/hand system under hierarchical control. The results demonstrate that any desired normal joint motion can be accurately tracked with the proposed algorithm. These simulation results indicate that the controller resolved the indeterminate problem redundancy in a physiologic manner, and show that the control scheme was robust to parameter uncertainty and to sensor noise.

  13. Changes in Ultrasonographic Vascularity Upon Initiation of Adalimumab Combination Therapy in Rheumatoid Arthritis Patients With an Inadequate Response to Methotrexate.

    PubMed

    Kaeley, Gurjit S; Nishio, Midori J; Goyal, Janak R; MacCarter, Daryl K; Wells, Alvin F; Chen, Su; Kupper, Hartmut; Kalabic, Jasmina

    2016-11-01

    To assess joint disease activity by ultrasound (US) in patients with rheumatoid arthritis (RA) initiating treatment with adalimumab (ADA) plus methotrexate (MTX). Data for this post hoc analysis originated from the MUSICA trial (ClinicalTrials.gov identifier: NCT01185288), which evaluated the efficacy of initiating ADA (40 mg every other week) plus 7.5 or 20 mg/week MTX in 309 patients with RA with an inadequate response to MTX. Synovial vascularization over 24 weeks was assessed bilaterally at metacarpophalangeal joint 2 (MCP2), MCP3, MCP5, metatarsophalangeal joint 5, and the wrists by power Doppler US (PDUS). A semiquantitative 4-grade scale was used. Disease activity was assessed using the Disease Activity Score in 28 joints using the C-reactive protein level (DAS28-CRP) and Simplified Disease Activity Index (SDAI). The correlation between continuous variables was assessed using Pearson's correlation coefficient. After 24 weeks of treatment with ADA plus MTX, rapid improvements in the mean synovial vascularity score were observed; the greatest improvements were in MCP2 (-0.5), MCP3 (-0.4), and the wrist (-0.4). At week 24, patients with the lowest DAS28-CRP (<2.6) had the lowest mean 5-joint and 3-joint composite synovial vascularity scores. The 5-joint and 3-joint scores were strongly correlated (ρ > 0.9). Synovial vascularity scores correlated poorly with DAS28, swollen joint count in 66 joints (SJC66), SJC28, tender joint count in 68 joints (TJC68), TJC28, Clinical Disease Activity Index (CDAI), SDAI, physician's global assessment, patient's global assessment of pain, and disease duration (ρ < 0.2). Thirty-two (70%) of 46 patients with a DAS28-CRP of <2.6, and 11 (58%) of 19 patients with an SDAI indicating remission had at least 1 joint with a synovial vascularity score of ≥1. PDUS detects changes in synovial vascularity in RA patients treated with ADA plus MTX, and residual synovial vascularity in patients in whom clinical disease control has been achieved. © 2016 The Authors. Arthritis & Rheumatology published by Wiley Periodicals, Inc. on behalf of the American College of Rheumatology.

  14. Forces and moments generated by the human arm: Variability and control

    PubMed Central

    Xu, Y; Terekhov, AV; Latash, ML; Zatsiorsky, VM

    2012-01-01

    This is an exploratory study of the accurate endpoint force vector production by the human arm in isometric conditions. We formulated three common-sense hypotheses and falsified them in the experiment. The subjects (n=10) exerted static forces on the handle in eight directions in a horizontal plane for 25 seconds. The forces were of 4 magnitude levels (10 %, 20%, 30% and 40% of individual MVC). The torsion moment on the handle (grasp moment) was not specified in the instruction. The two force components and the grasp moment were recorded, and the shoulder, elbow, and wrist joint torques were computed. The following main facts were observed: (a) While the grasp moment was not prescribed by the instruction, it was always produced. The moment magnitude and direction depended on the instructed force magnitude and direction. (b) The within-trial angular variability of the exerted force vector (angular precision) did not depend on the target force magnitude (a small negative correlation was observed). (c) Across the target force directions, the variability of the exerted force magnitude and directional variability exhibited opposite trends: In the directions where the variability of force magnitude was maximal, the directional variability was minimal and vice versa. (d) The time profiles of joint torques in the trials were always positively correlated, even for the force directions where flexion torque was produced at one joint and extension torque was produced at the other joint. (e) The correlations between the grasp moment and the wrist torque were negative across the tasks and positive within the individual trials. (f) In static serial kinematic chains, the pattern of the joint torques distribution could not be explained by an optimization cost function additive with respect to the torques. Plans for several future experiments have been suggested. PMID:23080084

  15. [The Effect of Activation of the Shoulder Girdle Muscles on Functional Outcomes of Rehabilitation in Patients with Surgically Treated Distal Radius Fractures].

    PubMed

    Jančíková, V; Opavský, J; Dráč, P; Krobot, A; Čižmář, I

    2017-01-01

    PURPOSE OF THE STUDY The aim of the study was to assess the functional outcomes of rehabilitation in patients with surgically treated distal radius fractures in the early postoperative period. We compared the functional outcomes of patients undergoing standard rehabilitation with the group of patients whose postoperative rehabilitation was extended with shoulder girdle exercises of the affected upper limb while the wrist was immobilized. Several indices and variables were used for the assessment of the functional therapeutic outcomes of the affected wrist. MATERIAL AND METHODS Forty patients (32 females and 8 males, the mean age 60.5 years) with distal radius fractures treated by internal fixation using volar surgical approach were involved in the study between 2013-2016. The tested subjects were randomized and split into two groups according to the selected method of rehabilitation. The tested subjects with standard rehabilitation extended with shoulder girdle muscles activation were labelled as group I. It included patients (n = 20) of the mean age 59.8 (age range 42-73 years) with immobilized wrist (i.e. for 3-4 weeks) performing shoulder girdle muscles exercises at the same time. Furthermore, standard kinesiotherapy continued after their fixation was removed. The other tested group, labelled as group II (n = 20), the mean age 61.3 (variation 40-74 years of age) involved patients with distal radius fractures. Only standard rehabilitation was performed in this group as late as their forearm fixation was removed. The following indices and parameters were assessed in the early postoperative period (i.e. by 8 weeks after the fixation removal): wrist and fingers range of motion (ROM), hand grip strength (dynamometry), local swelling, pain, scores of a nine hole peg test (NHPT), and a DASH score. RESULTS After the fixation had been removed, the group I reported statistically significantly higher values of movement compared to the values of the contralateral limb in the following directions: dorsal flexion, palmar flexion, MP joints flexion, flexion of PIP joints (proximal interphalangeal), and flexion of DIP joints (distal interphalangeal). After eight weeks, the group I manifested significantly higher values in dorsal flexion, palmar flexion and ulnar deviation in the wrist. There were no significant differences in other movement directions. The hand grip strength mean value examined with a dynamometer was significantly higher in the group I in the sixth and eighth week of testing (group I - 58.9% strength of a healthy limb after six weeks, or 66.5% after eight weeks). The results in the group II were 49.9% strength of a healthy limb after six weeks, or 56.6% after eight weeks. The group I showed statistically significantly lower values of wrist swelling and higher finger dexterity in the NHPT in all measured weeks. Lower pain intensity in the group I during the measurements was observed. At the same time, this group showed significantly better results in the DASH score. DISCUSSION The results of this study are useful for clinical practice. They confirm a functional relation between the activity of hand muscles and the shoulder muscle activity. The differences in the functional ability of the hand and the functional state of the injured wrist were detected as early as in the early postoperative period. It could be stated that the tested subjects in the group I showed a greater and faster improvement in the physical function of the injured hand. This was also accompanied by a positive psychological effect. We had not found a study of a similar type in the available literature that we could have compared our submitted results to. CONCLUSIONS Shoulder girdle muscles exercises after a distal radius fracture, while wrist is immobilized, can evidently enhance functional capability and accelerate the hand-function restitution. Early functional outcomes of the injured wrist after the rehabilitation with shoulder girdle muscles exercises support the efficiency of this broadened rehabilitation protocol. Key words: distal radius frac,ture, hand, shoulder, functional treatment, rehabilitation.

  16. Quantitative Tester And Reconditioner For Hand And Arm

    NASA Technical Reports Server (NTRS)

    Engle, Gary; Bond, Malcolm; Naumann, Theodore

    1993-01-01

    Apparatus measures torques, forces, and motions of hand, wrist, forearm, elbow, and shoulder and aids in reconditioning muscles involved. Used to determine strengths and endurances of muscles, ranges of motion of joints, and reaction times. Provides quantitative data used to assess extent to which disuse, disease, or injury causes deterioration of muscles and of motor-coordination skills. Same apparatus serves as exercise machine to restore muscle performance by imposing electronically controlled, gradually increasing loads on muscles. Suitable for training and evaluating astronauts, field testing for workers' compensation claims, and physical therapy in hospitals. With aid of various attachments, system adapted to measure such special motions as pinching, rotation of wrist, and supination and pronation of the forearm. Attachments are gloves, wristlets, and sleeves.

  17. Cerebellar ataxia: abnormal control of interaction torques across multiple joints.

    PubMed

    Bastian, A J; Martin, T A; Keating, J G; Thach, W T

    1996-07-01

    1. We studied seven subjects with cerebellar lesions and seven control subjects as they made reaching movements in the sagittal plane to a target directly in front of them. Reaches were made under three different conditions: 1) "slow-accurate," 2) "fast-accurate," and 3) "fast as possible." All subjects were videotaped moving in a sagittal plane with markers on the index finger, wrist, elbow, and shoulder. Marker positions were digitized and then used to calculate joint angles. For each of the shoulder, elbow and wrist joints, inverse dynamics equations based on a three-segment limb model were used to estimate the net torque (sum of components) and each of the component torques. The component torques consisted of the torque due to gravity, the dynamic interaction torques induced passively by the movement of the adjacent joint, and the torque produced by the muscles and passive tissue elements (sometimes called "residual" torque). 2. A kinematic analysis of the movement trajectory and the change in joint angles showed that the reaches of subjects with cerebellar lesions were abnormal compared with reaches of control subjects. In both the slow-accurate and fast-accurate conditions the cerebellar subjects made abnormally curved wrist paths; the curvature was greater in the slow-accurate condition. During the slow-accurate condition, cerebellar subjects showed target undershoot and tended to move one joint at a time (decomposition). During the fast-accurate reaches, the cerebellar subjects showed target overshoot. Additionally, in the fast-accurate condition, cerebellar subjects moved the joints at abnormal rates relative to one another, but the movements were less decomposed. Only three subjects were tested in the fast as possible condition; this condition was analyzed only to determine maximal reaching speeds of subjects with cerebellar lesions. Cerebellar subjects moved more slowly than controls in all three conditions. 3. A kinetic analysis of torques generated at each joint during the slow-accurate reaches and the fast-accurate reaches revealed that subjects with cerebellar lesions produced very different torque profiles compared with control subjects. In the slow-accurate condition, the cerebellar subjects produced abnormal elbow muscle torques that prevented the normal elbow extension early in the reach. In the fast-accurate condition, the cerebellar subjects produced inappropriate levels of shoulder muscle torque and also produced elbow muscle torques that did not very appropriately with the dynamic interaction torques that occurred at the elbow. Lack of appropriate muscle torque resulted in excessive contributions of the dynamic interaction torque during the fast-accurate reaches. 4. The inability to produce muscle torques that predict, accommodate, and compensate for the dynamic interaction torques appears to be an important cause of the classic kinematic deficits shown by cerebellar subjects during attempted reaching. These kinematic deficits include incoordination of the shoulder and the elbow joints, a curved trajectory, and overshoot. In the fast-accurate condition, cerebellar subjects often made inappropriate muscle torques relative to the dynamic interaction torques. Because of this, interaction torques often determined the pattern of incoordination of the elbow and shoulder that produced the curved trajectory and target overshoot. In the slow-accurate condition, we reason that the cerebellar subjects may use a decomposition strategy so as to simplify the movement and not have to control both joints simultaneously. From these results, we suggest that a major role of the cerebellum is in generating muscle torques at a joint that will predict the interaction torques being generated by other moving joints and compensate for them as they occur.

  18. Functional Multijoint Position Reproduction Acuity in Overhead-Throwing Athletes

    PubMed Central

    Tripp, Brady L; Uhl, Timothy L; Mattacola, Carl G; Srinivasan, Cidambi; Shapiro, Robert

    2006-01-01

    Context: Baseball players rely on the sensorimotor system to uphold the balance between upper extremity stability and mobility while maintaining athletic performance. However, few researchers have studied functional multijoint measures of sensorimotor acuity in overhead-throwing athletes. Objective: To compare sensorimotor acuity between 2 high-demand functional positions and among planes of motion within individual joints and to describe a novel method of measuring sensorimotor function. Design: Single-session, repeated-measures design. Setting: University musculoskeletal research laboratory. Patients or Other Participants: Twenty-one National Collegiate Athletic Association Division I baseball players (age = 20.8 ± 1.5 years, height = 181.3 ± 5.1 cm, mass = 87.8 ± 9.1 kg) with no history of upper extremity injury or central nervous system disorder. Main Outcome Measure(s): We measured active multijoint position reproduction acuity in multiple planes using an electromagnetic tracking device. Subjects reproduced 2 positions: arm cock and ball release. We calculated absolute and variable error for individual motions at the scapulothoracic, glenohumeral, elbow, and wrist joints and calculated overall joint acuity with 3-dimensional variable error. Results: Acuity was significantly better in the arm-cock position compared with ball release at the scapulothoracic and glenohumeral joints. We observed significant differences among planes of motion within the scapulothoracic and glenohumeral joints at ball release. Scapulothoracic internal rotation and glenohumeral horizontal abduction and rotation displayed less acuity than other motions. Conclusions: We established the reliability of a functional measure of upper extremity sensorimotor system acuity in baseball players. Using this technique, we observed differences in acuity between 2 test positions and among planes of motion within the glenohumeral and scapulothoracic joints. Clinicians may consider these differences when designing and implementing sensorimotor system training. Our error scores are similar in magnitude to those reported using single-joint and single-plane measures. However, 3-dimensional, multijoint measures allow practical, unconstrained test positions and offer additional insight into the upper extremity as a functional unit. PMID:16791298

  19. Ultrasound disease activity of bilateral wrist and finger joints at three months reflects the clinical response at six months of patients with rheumatoid arthritis treated with biologic disease-modifying anti-rheumatic drugs.

    PubMed

    Kawashiri, Shin-Ya; Nishino, Ayako; Shimizu, Toshimasa; Umeda, Masataka; Fukui, Shoichi; Nakashima, Yoshikazu; Suzuki, Takahisa; Koga, Tomohiro; Iwamoto, Naoki; Ichinose, Kunihiro; Tamai, Mami; Nakamura, Hideki; Origuchi, Tomoki; Aoyagi, Kiyoshi; Kawakami, Atsushi

    2017-03-01

    We evaluated whether the early responsiveness of ultrasound synovitis can predict the clinical response in rheumatoid arthritis (RA) patients treated with biologic disease-modifying anti-rheumatic drugs (bDMARDs). Articular synovitis was assessed by ultrasound at 22 bilateral wrist and finger joints in 39 RA patients treated with bDMARDs. Each joint was assigned a gray-scale (GS) and power Doppler (PD) score from 0 to 3, and the sum of the GS or PD scores was considered to represent the ultrasound disease activity. We investigated the correlation of the change in ultrasound disease activity at three months with the EULAR response criteria at six months. GS and PD scores were significantly decreased at three months (p < 0.0001). The % changes of the GS and PD scores at three months were significantly higher at six months in moderate and good responders compared with non-responders (p < 0.05). These tendencies were numerically more prominent if clinical response was set as good responder or Disease Activity Score 28 remission. Poor improvement of ultrasound synovitis scores had good predictive value for non-responders at six months. The responsiveness of ultrasound disease activity is considered to predict further clinical response in RA patients treated with bDMARDs.

  20. Local performance optimization for a class of redundant eight-degree-of-freedom manipulators

    NASA Technical Reports Server (NTRS)

    Williams, Robert L., II

    1994-01-01

    Local performance optimization for joint limit avoidance and manipulability maximization (singularity avoidance) is obtained by using the Jacobian matrix pseudoinverse and by projecting the gradient of an objective function into the Jacobian null space. Real-time redundancy optimization control is achieved for an eight-joint redundant manipulator having a three-axis spherical shoulder, a single elbow joint, and a four-axis spherical wrist. Symbolic solutions are used for both full-Jacobian and wrist-partitioned pseudoinverses, partitioned null-space projection matrices, and all objective function gradients. A kinematic limitation of this class of manipulators and the limitation's effect on redundancy resolution are discussed. Results obtained with graphical simulation are presented to demonstrate the effectiveness of local redundant manipulator performance optimization. Actual hardware experiments performed to verify the simulated results are also discussed. A major result is that the partitioned solution is desirable because of low computation requirements. The partitioned solution is suboptimal compared with the full solution because translational and rotational terms are optimized separately; however, the results show that the difference is not significant. Singularity analysis reveals that no algorithmic singularities exist for the partitioned solution. The partitioned and full solutions share the same physical manipulator singular conditions. When compared with the full solution, the partitioned solution is shown to be ill-conditioned in smaller neighborhoods of the shared singularities.

  1. [Secondary tendon reconstruction on the thumb].

    PubMed

    Bickert, B; Kremer, T; Kneser, U

    2016-12-01

    Closed tendon ruptures of the thumb that require secondary reconstruction can affect the extensor pollicis longus (EPL), extensor pollicis brevis (EPB) and flexor pollicis longus (FPL) tendons. Treatment of rupture of the EPB tendon consists of refixation to the bone and temporary transfixation of the joint. In the case of preexisting or posttraumatic arthrosis, definitive arthrodesis of the thumb is the best procedure. Closed ruptures of the EPL and FPL tendons at the wrist joint cannot be treated by direct tendon suture. Rupture of the EPL tendon occurs after distal radius fractures either due to protruding screws or following conservative treatment especially in undisplaced fractures. Transfer of the extensor indicis tendon to the distal EPL stump is a good option and free interposition of the palmaris longus tendon is a possible alternative. The tension should be adjusted to slight overcorrection, which can be checked intraoperatively by performing the tenodesis test. Closed FPL ruptures at the wrist typically occur 3-6 months after osteosynthesis of distal radius fractures with palmar plates and are mostly characterized by crepitation and pain lasting for several weeks. They can be prevented by premature plate removal, synovectomy and carpal tunnel release. For treatment of a ruptured FPL tendon in adult patients the options for tendon reconstruction should be weighed up against the less complicated tenodesis or arthrodesis of the thumb interphalangeal joint.

  2. Wrist loading patterns during pommel horse exercises.

    PubMed

    Markolf, K L; Shapiro, M S; Mandelbaum, B R; Teurlings, L

    1990-01-01

    Gymnastics is a sport which involves substantial periods of upper extremity support as well as frequent impacts to the wrist. Not surprisingly, wrist pain is a common finding in gymnasts. Of all events, the pommel horse is the most painful. In order to study the forces of wrist impact, a standard pommel horse was instrumented with a specially designed load cell to record the resultant force of the hand on the pommel during a series of basic skills performed by a group of seventeen elite male gymnasts. The highest mean peak forces were recorded during the front scissors and flair exercises (1.5 BW) with peaks of up to 2.0 BW for some gymnasts. The mean peak force for hip circles at the center or end of the horse was 1.1 BW. The mean overall loading rate (initial contact to first loading peak) ranged from 5.2 BWs-1 (hip circles) to 10.6 BW s-1 (flairs). However, many recordings displayed localized initial loading spikes which occurred during 'hard' landings on the pommel. When front scissors were performed in an aggressive manner, the initial loading spikes averaged 1.0 BW in magnitude (maximum 1.8 BW) with an average rise time of 8.2 ms; calculated localized loading rates averaged 129 BW s-1 (maximum 219 BW s-1). These loading parameters are comparable to those encountered at heel strike during running. These impact forces and loading rates are remarkably high for an upper extremity joint not normally exposed to weight-bearing loads, and may contribute to the pathogenesis of wrist injuries in gymnastics.

  3. The radial approach to the wrist with styloidectomy: A cadaver study.

    PubMed

    Lecoq, F-A; Sébilo, A; Bellemère, P

    2017-09-01

    The radial approach to the wrist is already used in several surgical techniques such as radial styloidectomy and Zaidemberg's vascularized radial graft. The aim of our work was to describe the surgical anatomy of that approach and to determine the acceptable limits of radial oblique styloidectomy that does not damage the anterior and posterior radiocarpal ligaments. This radial approach was performed on 11 cadaver specimens. The superficial branches of the radial nerve and the antebrachial cephalic vein were carefully located in the superficial plane. The radiocarpal articular capsule was opened longitudinally between the first and second compartments of the extensor tendons. We drew the oblique radial styloidectomy line at 3, 6 and 9mm from the apex of radial styloid process on the articular surface and then measured the width of ligaments theoretically taken away by the styloidectomy. An oblique radial styloidectomy of less than 6mm preserved the anterior and posterior radiocarpal ligaments. There was one case of radial artery damage while opening the joint capsule. The radial approach to the wrist as described in this work provided good access to the radial styloid process, the radioscaphoid joint and the proximal pole of the scaphoid, if the approach is done carefully to preserve the superficial branches of the radial nerve, the antebrachial cephalic vein and the radial artery. Radial styloidectomy can be performed up to 6mm from the apex without significantly damaging the radiocarpal ligaments, particularly the volar ones. Copyright © 2017 SFCM. Published by Elsevier Masson SAS. All rights reserved.

  4. Robot-Aided Neurorehabilitation: A Robot for Wrist Rehabilitation

    PubMed Central

    Krebs, Hermano Igo; Volpe, Bruce T.; Williams, Dustin; Celestino, James; Charles, Steven K.; Lynch, Daniel; Hogan, Neville

    2009-01-01

    In 1991, a novel robot, MIT-MANUS, was introduced to study the potential that robots might assist in and quantify the neuro-rehabilitation of motor function. MIT-MANUS proved an excellent tool for shoulder and elbow rehabilitation in stroke patients, showing in clinical trials a reduction of impairment in movements confined to the exercised joints. This successful proof of principle as to additional targeted and intensive movement treatment prompted a test of robot training examining other limb segments. This paper focuses on a robot for wrist rehabilitation designed to provide three rotational degrees-of-freedom. The first clinical trial of the device will enroll 200 stroke survivors. Ultimately 160 stroke survivors will train with both the proximal shoulder and elbow MIT-MANUS robot, as well as with the novel distal wrist robot, in addition to 40 stroke survivor controls. So far 52 stroke patients have completed the robot training (ongoing protocol). Here, we report on the initial results on 36 of these volunteers. These results demonstrate that further improvement should be expected by adding additional training to other limb segments. PMID:17894265

  5. Robot-aided neurorehabilitation: a robot for wrist rehabilitation.

    PubMed

    Krebs, Hermano Igo; Volpe, Bruce T; Williams, Dustin; Celestino, James; Charles, Steven K; Lynch, Daniel; Hogan, Neville

    2007-09-01

    In 1991, a novel robot, MIT-MANUS, was introduced to study the potential that robots might assist in and quantify the neuro-rehabilitation of motor function. MIT-MANUS proved an excellent tool for shoulder and elbow rehabilitation in stroke patients, showing in clinical trials a reduction of impairment in movements confined to the exercised joints. This successful proof of principle as to additional targeted and intensive movement treatment prompted a test of robot training examining other limb segments. This paper focuses on a robot for wrist rehabilitation designed to provide three rotational degrees-of-freedom. The first clinical trial of the device will enroll 200 stroke survivors. Ultimately 160 stroke survivors will train with both the proximal shoulder and elbow MIT-MANUS robot, as well as with the novel distal wrist robot, in addition to 40 stroke survivor controls. So far 52 stroke patients have completed the robot training (ongoing protocol). Here, we report on the initial results on 36 of these volunteers. These results demonstrate that further improvement should be expected by adding additional training to other limb segments.

  6. Real-time and wearable functional electrical stimulation system for volitional hand motor function control using the electromyography bridge method

    PubMed Central

    Wang, Hai-peng; Bi, Zheng-yang; Zhou, Yang; Zhou, Yu-xuan; Wang, Zhi-gong; Lv, Xiao-ying

    2017-01-01

    Voluntary participation of hemiplegic patients is crucial for functional electrical stimulation therapy. A wearable functional electrical stimulation system has been proposed for real-time volitional hand motor function control using the electromyography bridge method. Through a series of novel design concepts, including the integration of a detecting circuit and an analog-to-digital converter, a miniaturized functional electrical stimulation circuit technique, a low-power super-regeneration chip for wireless receiving, and two wearable armbands, a prototype system has been established with reduced size, power, and overall cost. Based on wrist joint torque reproduction and classification experiments performed on six healthy subjects, the optimized surface electromyography thresholds and trained logistic regression classifier parameters were statistically chosen to establish wrist and hand motion control with high accuracy. Test results showed that wrist flexion/extension, hand grasp, and finger extension could be reproduced with high accuracy and low latency. This system can build a bridge of information transmission between healthy limbs and paralyzed limbs, effectively improve voluntary participation of hemiplegic patients, and elevate efficiency of rehabilitation training. PMID:28250759

  7. Wrist electrogoniometry: are current mathematical correction procedures effective in reducing crosstalk in functional assessment?

    PubMed

    Foltran, Fabiana A; Silva, Luciana C C B; Sato, Tatiana O; Coury, Helenice J C G

    2013-01-01

    The recording of human movement is an essential requirement for biomechanical, clinical, and occupational analysis, allowing assessment of postural variation, occupational risks, and preventive programs in physical therapy and rehabilitation. The flexible electrogoniometer (EGM), considered a reliable and accurate device, is used for dynamic recordings of different joints. Despite these advantages, the EGM is susceptible to measurement errors, known as crosstalk. There are two known types of crosstalk: crosstalk due to sensor rotation and inherent crosstalk. Correction procedures have been proposed to correct these errors; however no study has used both procedures in clinical measures for wrist movements with the aim to optimize the correction. To evaluate the effects of mathematical correction procedures on: 1) crosstalk due to forearm rotation, 2) inherent sensor crosstalk; and 3) the combination of these two procedures. 43 healthy subjects had their maximum range of motion of wrist flexion/extension and ulnar/radials deviation recorded by EGM. The results were analyzed descriptively, and procedures were compared by differences. There was no significant difference in measurements before and after the application of correction procedures (P<0.05). Furthermore, the differences between the correction procedures were less than 5° in most cases, having little impact on the measurements. Considering the time-consuming data analysis, the specific technical knowledge involved, and the inefficient results, the correction procedures are not recommended for wrist recordings by EGM.

  8. Principal components of wrist circumduction from electromagnetic surgical tracking.

    PubMed

    Rasquinha, Brian J; Rainbow, Michael J; Zec, Michelle L; Pichora, David R; Ellis, Randy E

    2017-02-01

    An electromagnetic (EM) surgical tracking system was used for a functionally calibrated kinematic analysis of wrist motion. Circumduction motions were tested for differences in subject gender and for differences in the sense of the circumduction as clockwise or counter-clockwise motion. Twenty subjects were instrumented for EM tracking. Flexion-extension motion was used to identify the functional axis. Subjects performed unconstrained wrist circumduction in a clockwise and counter-clockwise sense. Data were decomposed into orthogonal flexion-extension motions and radial-ulnar deviation motions. PCA was used to concisely represent motions. Nonparametric Wilcoxon tests were used to distinguish the groups. Flexion-extension motions were projected onto a direction axis with a root-mean-square error of [Formula: see text]. Using the first three principal components, there was no statistically significant difference in gender (all [Formula: see text]). For motion sense, radial-ulnar deviation distinguished the sense of circumduction in the first principal component ([Formula: see text]) and in the third principal component ([Formula: see text]); flexion-extension distinguished the sense in the second principal component ([Formula: see text]). The clockwise sense of circumduction could be distinguished by a multifactorial combination of components; there were no gender differences in this small population. These data constitute a baseline for normal wrist circumduction. The multifactorial PCA findings suggest that a higher-dimensional method, such as manifold analysis, may be a more concise way of representing circumduction in human joints.

  9. [Ganglions of the wrist: proposals for topographical systematization and natural history].

    PubMed

    Kuhlmann, J-N; Luboinski, J; Baux, S; Mimoun, M

    2003-06-01

    We looked for the anatomic origin and mechanism of constitution of the so-called "ganglions" of the wrist. Fifty-nine formations considered to be synovial ganglions were dissected and removed according to the same protocol by the same surgeon. Eleven were re-examined by a pathologist. All ganglions were extra-articular but had intra- and extra-capsular components. The extra-capsular part was the clinically palpable main cyst. The intra-capsular part was composed of the cystic stalk and its base of implantation. An intra-capsular stalk was present in 58 cases. The stalk was situated between the joint synovium and the capsula which it perforated at a weak point between two ligaments, forming a collar before expanding outwardly. Based on our findings, we propose a topographical systematization and natural history of ganglions of the wrist. The stalk's implantation base was always located on bone and found in the intermediate area of Colomniati and Soubbotine, which lies outside the articular cartilage between the synovium and the ligamentous capsula. This area is exposed to mechanical stress initiating histological degenerative lesions, particularly mucoid degeneration. At the radiocarpal joint, the stalk's base of implantation was located at the distal end of the lateral dorsal or volar edge of the lunate bone or at the corresponding part of the scaphoid. The collar of the proximal ganglions was situated between the dorsal radiocarpal and transverse scaphotriquetral ligament. The collar of distal dorsal ganglions was situated between the transverse scaphotriquetral and the trapezotriquetral ligament. The collar of the lateral ganglions was situated between the lateral collateral and the transverse ligament. The collar of the volar ganglions was situated between the stylocarpal ligament and the radiolunotriquetral ligament, or between the different stylocarpal ligaments. At the level of the scaphotrapezal joint, the stalk's base of implantation was located near the collateral edge of the distal surface of the joint with the collar between the distal scaphoidal ligaments. The palmar cysts exhibited a collar between the stylocarpal ligaments and the radiolunotriquetral ligament or between the different stylocarpal ligaments. At pathology examination, the lesions were not found to be different from those observed in other connective tissues exposed to overuse or repeated microtrauma (sports, occupational exposure). Anatomic conditions inside the joint capsula excluded extension of the mucoid degeneration transversally. The only issue was through the capsula, allowing the mucus enclosed in the connective tissue fibers to form the main cyst. Knowledge of these different processes enabled a topographical systematization useful for complete surgical or arthroscopic removal of the ganglion. Complete resection would prevent recurrence.

  10. A Prospective Study of Injuries and Injury Risk Factors Among Army Wheel Vehicle Mechanics

    DTIC Science & Technology

    2006-08-01

    metacarpalphalangeal joint and 110* at the proximal interphalangeal joint of the third finger . While keeping the forearm on the padded table surface...ground, then return to the starting point with elbows fully extended. For sit-up, the Soldier bent his knees at a 90’ angle, interlocked his fingers ...Wrist 5 5.4 Hand 2 2.2 Finger 3 3.3 Upper Back 1 1.1 Lower Back Lower Back 16 17.4 Pelvic Area 1 1.1 Anterior Thigh 1 1.1 Knee 17 18.5 Lower Body Calf 1

  11. Physical risk factors identification based on body sensor network combined to videotaping.

    PubMed

    Vignais, Nicolas; Bernard, Fabien; Touvenot, Gérard; Sagot, Jean-Claude

    2017-11-01

    The aim of this study was to perform an ergonomic analysis of a material handling task by combining a subtask video analysis and a RULA computation, implemented continuously through a motion capture system combining inertial sensors and electrogoniometers. Five workers participated to the experiment. Seven inertial measurement units, placed on the worker's upper body (pelvis, thorax, head, arms, forearms), were implemented through a biomechanical model of the upper body to continuously provide trunk, neck, shoulder and elbow joint angles. Wrist joint angles were derived from electrogoniometers synchronized with the inertial measurement system. Worker's activity was simultaneously recorded using video. During post-processing, joint angles were used as inputs to a computationally implemented ergonomic evaluation based on the RULA method. Consequently a RULA score was calculated at each time step to characterize the risk of exposure of the upper body (right and left sides). Local risk scores were also computed to identify the anatomical origin of the exposure. Moreover, the video-recorded work activity was time-studied in order to classify and quantify all subtasks involved into the task. Results showed that mean RULA scores were at high risk for all participants (6 and 6.2 for right and left sides respectively). A temporal analysis demonstrated that workers spent most part of the work time at a RULA score of 7 (right: 49.19 ± 35.27%; left: 55.5 ± 29.69%). Mean local scores revealed that most exposed joints during the task were elbows, lower arms, wrists and hands. Elbows and lower arms were indeed at a high level of risk during the total time of a work cycle (100% for right and left sides). Wrist and hands were also exposed to a risky level for much of the period of work (right: 82.13 ± 7.46%; left: 77.85 ± 12.46%). Concerning the subtask analysis, subtasks called 'snow thrower', 'opening the vacuum sealer', 'cleaning' and 'storing' have been identified as the most awkward for right and left sides given mean RULA scores and percentages of time spent at risky levels. Results analysis permitted to suggest ergonomic recommendations for the redesign of the workstation. Contributions of the proposed innovative system dedicated to physical ergonomic assessment are further discussed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Quantifying the dynamic wing morphing of hovering hummingbird

    PubMed Central

    Nakata, Toshiyuki; Kitamura, Ikuo; Tanaka, Hiroto

    2017-01-01

    Animal wings are lightweight and flexible; hence, during flapping flight their shapes change. It has been known that such dynamic wing morphing reduces aerodynamic cost in insects, but the consequences in vertebrate flyers, particularly birds, are not well understood. We have developed a method to reconstruct a three-dimensional wing model of a bird from the wing outline and the feather shafts (rachides). The morphological and kinematic parameters can be obtained using the wing model, and the numerical or mechanical simulations may also be carried out. To test the effectiveness of the method, we recorded the hovering flight of a hummingbird (Amazilia amazilia) using high-speed cameras and reconstructed the right wing. The wing shape varied substantially within a stroke cycle. Specifically, the maximum and minimum wing areas differed by 18%, presumably due to feather sliding; the wing was bent near the wrist joint, towards the upward direction and opposite to the stroke direction; positive upward camber and the ‘washout’ twist (monotonic decrease in the angle of incidence from the proximal to distal wing) were observed during both half-strokes; the spanwise distribution of the twist was uniform during downstroke, but an abrupt increase near the wrist joint was found during upstroke. PMID:28989736

  13. Radioscapholunate fusion with triquetrum and distal pole of scaphoid excision: long-term follow-up.

    PubMed

    Ha, Ngoc B; Phadnis, Joideep; MacLean, Simon B M; Bain, Gregory I

    2018-02-01

    The purpose of this study was to assess the long-term outcomes of radioscapholunate fusion, with and without distal pole of scaphoid excision and excision of the triquetrum. These compromised three operative groups. Seventeen patients were identified with a minimum of 10 years follow-up, with a mean of 15 years (range 10-19). Fifteen of the 17 patients were satisfied with their outcome. Two were converted to total wrist fusion. The mean outcomes scores were; pain visual analogue scale score 2.1/10, Quick Disabilities of the Arm, Shoulder, and Hand 29 and Modified Mayo Wrist score 60. Patients with excision of the triquetrum had a mean radial-ulnar arc increase of 10° compared with the other two groups, but this was not statistically significant. The mean space for the scaphocapitate joint was 1.7 mm and lunocapitate joint was 1.3 mm at latest follow-up. Close adherence to the indications and surgical technique provided a sustainable good clinical outcome. Patients who obtained a good result at 2 years were likely to achieve a good long-term outcome. IV.

  14. [Treatment of triangular fibrocartilage complex tear under wrist arthroscopy].

    PubMed

    Mi, Kun; Liu, Wu; Liu, Pengfei; Feng, Zhibin; Li, Yuwen; Hui, Guisheng

    2011-01-01

    To evaluate the treatment and effects of wrist arthroscopy in tear of triangular fibrocartilage complex (TFCC). Between January 2006 and December 2008, 16 patients with tear of TFCC were treated. Of 16 patients, 11 were male and 5 were female with an average age of 32.5 years (range, 25-51 years). Injury was caused by sprain in 12 cases, and by falling in 4 cases. The locations were the left side in 10 cases and the right side in 6 cases. The mean injury duration was 3 months to 6 years and 2 months. The main clinical symptoms included wrist powerlessness and ulnar-sided wrist pain which was aggravated with clench fist and lifting heavy things. The results of the ulnar-sided wrist stress test were positive in 14 cases and negative in 2 cases. The preoperative values of wrist range of motion (ROM) were (45.58 +/- 5.18) degrees at volar flexion, (41.22 +/- 3.83) degrees at dorsal extension, (17.82 +/- 2.48) degrees at radial deviation, (21.35 +/- 4.61) degrees at ulnar deviation, (69.85 +/- 8.36) degrees at pronation, and (70.13 +/- 6.34) degrees at supination. According to Palmer standard, 10 cases of IA were treated with debridement; 3 cases of IB with suture and 1 of them failed and was partially excised; 2 cases of IC with debridement on triangular fibrocartilage disc, ulnolunate ligament, and ulnotriguetrum ligament; and 1 case of ID with trimming plastic operation. All incisions healed by first intention, and no complications of joint infection or neurovascular injury was found. All patients were followed up 14-38 months (mean, 18.5 months). Fifteen patients were restored to normal life and work without ulnar-sided wrist pain. One patient had no pain, but he had wrist powerless. The values of ROM at last follow-up were (50.16 +/- 6.21) degrees at volar flexion, (45.37 +/- 4.65) degrees at dorsal extension, (18.95 +/- 3.56) degrees at radial deviation, (26.28 +/- 5.09) degrees at ulnar deviation, (78.87 +/- 7.69) degrees at pronation, and (76.46 +/- 8.31) degrees at supination; showing significant differences when compared with preoperative values (P < 0.05). According to Green-O'Brien standard, the results were excellent in 9 cases, good in 6 cases, fair in 1 case, and the excellent and good rate was 93.75%. The wrist arthroscopy not only can definitely diagnose tear of TFCC, but also is useful for treatment. In addition, the incision is small and the function is easy to recover, and the occurrence of chronic ulnar-sided wrist pain can be effectively avoided.

  15. Immediate effect of a functional wrist orthosis for children with cerebral palsy or brain injury: A randomized controlled trial.

    PubMed

    Jackman, Michelle; Novak, Iona; Lannin, Natasha; Galea, Claire

    2017-10-28

    Two-group randomized controlled trial. Upper limb orthoses worn during functional tasks are commonly used in pediatric neurologic rehabilitation, despite a paucity of high-level evidence. The purpose of this study was to investigate if a customized functional wrist orthosis, when placed on the limb, leads to an immediate improvement in hand function for children with cerebral palsy or brain injury. A 2-group randomized controlled trial involving 30 children was conducted. Participants were randomized to either receive a customized functional wrist orthosis (experimental, n = 15) or not receive an orthosis (control, n = 15). The box and blocks test was administered at baseline and repeated 1 hour after experimental intervention, with the orthosis on if randomized to the orthotic group. After intervention, there were no significant differences on the box and blocks test between the orthotic group (mean, 10.13; standard deviation, 11.476) and the no orthotic group (mean, 14.07; standard deviation, 11.106; t[28], -0.954; P = .348; and 95% confidence interval, -12.380 to 4.513). In contrast to the findings of previous studies, our results suggest that a functional wrist orthosis, when supporting the joint in a 'typical' position, may not lead to an immediate improvement in hand function. Wearing a functional wrist orthosis did not lead to an immediate improvement in the ability of children with cerebral palsy or brain injury to grasp and release. Further research is needed combining upper limb orthoses with task-specific training and measuring outcomes over the medium to long term. Copyright © 2017 Hanley & Belfus. All rights reserved.

  16. Limited arthrodesis of the wrist for treatment of giant cell tumor of the distal radius.

    PubMed

    Flouzat-Lachaniette, Charles-Henri; Babinet, Antoine; Kahwaji, Antoine; Anract, Philippe; Biau, David-Jean

    2013-08-01

    To present the functional results of a technique of radiocarpal arthrodesis and reconstruction with a structural nonvascularized autologous bone graft after en bloc resection of giant cell tumors of the distal radius. A total of 13 patients with a mean age of 37 years with aggressive giant cell tumor (Campanacci grade III) of distal radius were managed with en bloc resection and reconstruction with a structural nonvascularized bone graft. The primary outcome measure was the disability evaluated by the Musculoskeletal Tumor Society rating score of limb salvage. Secondary outcomes included survival of the reconstruction measured from the date of the operation to revision procedure for any reason (mechanical, infectious, or oncologic). Other outcomes included active wrist motion and ability to resume work. Mean follow-up period was 6 years (range, 2-14 y). The median arc of motion at the midcarpal joint was 40°, median wrist flexion was 20°, and median extension was 10°. The median Musculoskeletal Tumor Society score based on the analysis of factors pertinent to the patient as a whole (pain, functional activities, and emotional acceptance) and specific to the upper limb (positioning of the hand, manual dexterity, and lifting ability) was 86%. Five patients underwent a second surgical procedure. The cumulative probability of reoperation for mechanical reason was 31% at similar follow-up times at 2, 5, and 10 years. This technique provided a stable wrist and partially restored wrist motion with limited pain. However, further surgical procedures may be necessary to reach this goal. Therapeutic IV. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  17. Resting Orientations of Dinosaur Scapulae and Forelimbs: A Numerical Analysis, with Implications for Reconstructions and Museum Mounts.

    PubMed

    Senter, Phil; Robins, James H

    2015-01-01

    The inclination of the scapular blade and the resting pose of the forelimb in dinosaurs differ among reconstructions and among skeletal mounts. For most dinosaurian taxa, no attempt has previously been made to quantify the correct resting positions of these elements. Here, we used data from skeletons preserved in articulation to quantify the resting orientations of the scapula and forelimb in dinosaurs. Specimens were included in the study only if they were preserved lying on their sides; for each specimen the angle between forelimb bones at a given joint was included in the analysis only if the joint was preserved in articulation. Using correlation analyses of the angles between the long axis of the sacrum, the first dorsal centrum, and the scapular blade in theropods and Eoraptor, we found that vertebral hyperextension does not influence scapular orientation in saurischians. Among examined taxa, the long axis of the scapular blade was found to be most horizontal in bipedal saurischians, most vertical in basal ornithopods, and intermediate in hadrosauroids. We found that in bipedal dinosaurs other than theropods with semilunate carpals, the resting orientation of the elbow is close to a right angle and the resting orientation of the wrist is such that the hand exhibits only slight ulnar deviation from the antebrachium. In theropods with semilunate carpals the elbow and wrist are more flexed at rest, with the elbow at a strongly acute angle and with the wrist approximately at a right angle. The results of our study have important implications for correct orientations of bones in reconstructions and skeletal mounts. Here, we provide recommendations on bone orientations based on our results.

  18. Exploring cartilage damage in gout using 3-T MRI: distribution and associations with joint inflammation and tophus deposition.

    PubMed

    Popovich, I; Dalbeth, N; Doyle, A; Reeves, Q; McQueen, F M

    2014-07-01

    Few imaging studies have investigated cartilage in gout. Magnetic resonance imaging (MRI) can image cartilage damage and also reveals other features of gouty arthropathy. The objective was to develop and validate a system for quantifying cartilage damage in gout. 3-T MRI scans of the wrist were obtained in 40 gout patients. MRI cartilage damage was quantified using an adaptation of the radiographic Sharp van der Heijde score. Two readers scored cartilage loss at 7 wrist joints: 0 (normal), 1 (partial narrowing), 2 (complete narrowing) and concomitant osteoarthritis was recorded. Bone erosion, bone oedema and synovitis were scored (RAMRIS) and tophi were assessed. Correlations between radiographic and MRI cartilage scores were investigated, as was the reliability of the MRI cartilage score and its associations. The GOut MRI Cartilage Score (GOMRICS) was highly correlated with the total Sharp van der Heijde (SvdH) score and the joint space narrowing component (R = 0.8 and 0.71 respectively, p < 0.001). Reliability was high (intraobserver, interobserver ICCs = 0.87 [0.57-0.97], 0.64 [0.41-0.79] respectively), and improved on unenhanced scans; interobserver ICC = 0.82 [0.49-0.95]. Cartilage damage was predominantly focal (82% of lesions) and identified in 40 out of 280 (14%) of joints. Cartilage scores correlated with bone erosion (R = 0.57), tophus size (R = 0.52), and synovitis (R = 0.55), but not bone oedema scores. Magnetic resonance imaging can be used to investigate cartilage in gout. Cartilage damage was relatively uncommon, focal, and associated with bone erosions, tophi and synovitis, but not bone oedema. This emphasises the unique pathophysiology of gout.

  19. Baseline serum level of matrix metalloproteinase-3 as a biomarker of progressive joint damage in rheumatoid arthritis patients.

    PubMed

    Galil, Sahar Mahfouz Abdel; El-Shafey, Abeer Mohamed; Hagrass, Hoda A; Fawzy, Faten; Sammak, Ahmed El

    2016-04-01

    Matrix metalloproteinase-3 (MMP-3) plays a pivotal role in the destruction of bone and degradation of cartilage components in rheumatoid arthritis (RA). We aimed in this study to analyze the relation between baseline levels of MMP-3 and the progression of joint damage in RA. Eighty-one untreated RA patients with joint symptoms for <1 year were evaluated at baseline and after 12 months as regards erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), rheumatoid factor (RF), anti-cyclic citrullinated peptide (anti-CCP) and plain X-ray of both hands and wrists. Baseline levels of MMP-3 were measured by enzyme-linked immunosorbent assay and magnetic resonance imaging (MRI) of hands/wrists was performed. Disease Activity Score (DAS28) and Health Assessment Questionnaire (HAQ) were performed at baseline evaluation and after 12 months. The baseline MMP-3 levels were significantly higher in the high-progression group compared with the low-progression one (95.75 ± 42.84 vs. 50.45 ± 12.83, P < 0.001). There was a positive correlation between baseline levels of MMP-3 and MRI erosion score and other baseline clinical parameters, except for HAQ and the van der Heijde modification of the Sharp scoring system (SvdH) scores, while after 12 months, there were high positive correlations between MMP-3 and SvdH score, as well as all parameters except for ESR. Serum baseline levels of MMP-3 are strong prognostic markers of disease activity, and act well as an early predictor of progressive joint damage in recent-onset RA disease. © 2014 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.

  20. Quantification and visualization of coordination during non-cyclic upper extremity motion.

    PubMed

    Fineman, Richard A; Stirling, Leia A

    2017-10-03

    There are many design challenges in creating at-home tele-monitoring systems that enable quantification and visualization of complex biomechanical behavior. One such challenge is robustly quantifying joint coordination in a way that is intuitive and supports clinical decision-making. This work defines a new measure of coordination called the relative coordination metric (RCM) and its accompanying normalization schemes. RCM enables quantification of coordination during non-constrained discrete motions. Here RCM is applied to a grasping task. Fifteen healthy participants performed a reach, grasp, transport, and release task with a cup and a pen. The measured joint angles were then time-normalized and the RCM time-series were calculated between the shoulder-elbow, shoulder-wrist, and elbow-wrist. RCM was normalized using four differing criteria: the selected joint degree of freedom, angular velocity, angular magnitude, and range of motion. Percent time spent in specified RCM ranges was used asa composite metric and was evaluated for each trial. RCM was found to vary based on: (1) chosen normalization scheme, (2) the stage within the task, (3) the object grasped, and (4) the trajectory of the motion. The RCM addresses some of the limitations of current measures of coordination because it is applicable to discrete motions, does not rely on cyclic repetition, and uses velocity-based measures. Future work will explore clinically relevant differences in the RCM as it is expanded to evaluate different tasks and patient populations. Copyright © 2017. Published by Elsevier Ltd.

  1. Radiographic assessment of skeletal maturation stages for orthodontic patients: hand-wrist bones or cervical vertebrae?

    PubMed

    Lai, Eddie Hsiang-Hua; Liu, Jen-Pei; Chang, Jenny Zwei-Chieng; Tsai, Shih-Jaw; Yao, Chung-Chen Jane; Chen, Mu-Hsiung; Chen, Yi-Jane; Lin, Chun-Pin

    2008-04-01

    The skeletal maturation status of a growing patient can influence the selection of orthodontic treatment procedures. Either lateral cephalometric or hand-wrist radiography can be used to assess skeletal development. In this study, we examined the correlation between the maturation stages of cervical vertebrae and hand-wrist bones in Taiwanese individuals. The study group consisted of 330 male and 379 female subjects ranging in age from 8 to 18 years. A total of 709 hand-wrist and 709 lateral cephalometric radiographs were analyzed. Hand-wrist maturation stages were assessed using National Taiwan University Hospital Skeletal Maturation Index (NTUH-SMI). Cervical vertebral maturation stages were determined by the latest Cervical Vertebral Maturation Stage (CVMS) Index. Spearman's rank correlation was used to correlate the respective maturation stages assessed from the hand-wrist bones and the cervical vertebrae. The values of Spearman's rank correlation were 0.910 for males and 0.937 for females, respectively. These data confirmed a strong and significant correlation between CVMS and NTUH-SMI systems (p less than 0.001). After comparison of the mean ages of subjects in different stages of CVMS and NTU-SMI systems, we found that CVMS I corresponded to NTUH-SMI stages 1 and 2, CVMS II to NTUH-SMI stage 3, CVMS III to NTUHSMI stage 4, CVMS IV to NTUH-SMI stage 5, CVMS V to NTUH-SMI stages 6, 7 and 8, and CVMS VI to NTUH-SMI stage 9. Our results indicate that cervical vertebral maturation stages can be used to replace hand-wrist bone maturation stages for evaluation of skeletal maturity in Taiwanese individuals.

  2. Positioning, Splinting, and Contracture Management

    DTIC Science & Technology

    2011-01-01

    IP) joints in extension, thumb in palmar abduction, hip extension and abducted 20 (no external rotation), knee extension, and neutral ankle ...to skin breakdown are the heels,55 sacrum, ankles , wrists, elbows, and occipital area.8 Some options for splinting and positioning devices can be...children.70 In addition, moveable parts are difficult to anchor to small levers and the cognition and responsibilities needed for proper fit of dynamic

  3. Efficient Jacobian inversion for the control of simple robot manipulators

    NASA Technical Reports Server (NTRS)

    Fijany, Amir; Bejczy, Antal K.

    1988-01-01

    Symbolic inversion of the Jacobian matrix for spherical wrist arms is investigated. It is shown that, taking advantage of the simple geometry of these arms, the closed-form solution of the system Q = J-1X, representing a transformation from task space to joint space, can be obtained very efficiently. The solutions for PUMA, Stanford, and a six-revolute-joint coplanar arm, along with all singular points, are presented. The solution for each joint variable is found as an explicit function of the singular points which provides a better insight into the effect of different singular points on the motion and force exertion of each individual joint. For the above arms, the computation cost of the solution is on the same order as the cost of forward kinematic solution and it is significantly reduced if forward kinematic solution is already obtained. A comparison with previous methods shows that this method is the most efficient to date.

  4. The effect of robot dynamics on smoothness during wrist pointing.

    PubMed

    Erwin, Andrew; Pezent, Evan; Bradley, Joshua; O'Malley, Marcia K

    2017-07-01

    The improvement of movement smoothness over the course of therapy is one of the positive outcomes observed during robotic rehabilitation. Although movements are generally robust to disturbances, certain perturbations might disrupt an individual's ability to produce these smooth movements. In this paper, we explore how a rehabilitation robot's inherent dynamics impact movement smoothness during pointing tasks. Able-bodied participants made wrist pointing movements under four different operating conditions. Despite the relative transparency of the device, inherent dynamic characteristics negatively impacted movement smoothness. Active compensation for Coulomb friction effects failed to mitigate the degradation in smoothness. Assessment of movements that involved coupled motions of the robot's joints reduced the bias seen in single degree of freedom movements. When using robotic devices for assessment of movement quality, the impact of the inherent dynamics must be considered.

  5. Treatment of wrist and hand fractures with natural magnets: preliminary report.

    PubMed

    Costantino, Cosimo; Pogliacomi, Francesco; Passera, Francesco; Concari, Galeazzo

    2007-12-01

    The Authors, after having defined the phenomenon and the biological characteristics of natural magnets, evaluate their ability in accelerating the formation of bone callus in hand and wrist fractures compared to treatment with immobilization in a plaster cast. Forty patients (4 females and 37 males) between 20 and 86 years of age were treated. A small natural magnet was inserted in each of the plaster casts (diameter: 2cm, height: 0.5cm) made of 4 blocks in Neodymium-Iron-Boron, capable of generating 4 magnetic poles (2 positive and 2 negative) of diagonal alternate polarity that produced a symmetric, quadruple static magnetic field. The created magnetic flow was wavelike, concentrated in one direction, and developed a force up to 12,500 gauss. From this study it has emerged that inserting a quadruple magnet in a plaster cast in hand and wrist fractures results in the formation of bone callus in an average time that is 35% inferior to the "standard" time. Accelerating the healing of the fracture is important since it reduces immobilization time for the joints involved, avoiding subsequent weakness and stiffness and allowing the patient to begin rehabilitative physiotherapy sooner, which permits a faster functional recovery.

  6. Patterns of Transfer of Adaptation Among Body Segments

    NASA Technical Reports Server (NTRS)

    Seidler, R. D.; Bloomberg, J. J.; Stelmach, George E.

    2000-01-01

    Two experiments were conducted in order to determine the patterns of transfer of visuomotor adaptation between arm and head pointing. An altered gain of display of pointing movements was used to induce a conflict between visual and somatosensory representations. Two subject groups participated in Experiment One: group 1 adapted shoulder pointing movements, and group 2 adapted wrist pointing movements to a 0.5 gain of display. Following the adaptation regimen, subjects performed a transfer test in which the shoulder group performed wrist movements and the wrist group performed shoulder movements. The results demonstrated that both groups displayed typical adaptation curves, initially undershooting the target followed by a return to baseline performance. Transfer tests revealed that both groups had high transfer of the acquired adaptation to the other joint. Experiment Two followed a similar design except that group 1 adapted head pointing movements and group 2 adapted arm pointing movements. The arm adaptation had high transfer to head pointing while the head adaptation had very little transfer to arm pointing. These results imply that, while the arm segments may share a common target representation for goal-directed actions, individual but functionally dependent target representations may exist for the control of head and arm movements.

  7. A new myohaptic instrument to assess wrist motion dynamically.

    PubMed

    Manto, Mario; Van Den Braber, Niels; Grimaldi, Giuliana; Lammertse, Piet

    2010-01-01

    The pathophysiological assessment of joint properties and voluntary motion in neurological patients remains a challenge. This is typically the case in cerebellar patients, who exhibit dysmetric movements due to the dysfunction of cerebellar circuitry. Several tools have been developed, but so far most of these tools have remained confined to laboratories, with a lack of standardization. We report on a new device which combines the use of electromyographic (EMG) sensors with haptic technology for the dynamic investigation of wrist properties. The instrument is composed of a drivetrain, a haptic controller and a signal acquisition unit. Angular accuracy is 0.00611 rad, nominal torque is 6 N·m, maximal rotation velocity is 34.907 rad/sec, with a range of motion of -1.0472 to +1.0472 rad. The inertia of the motor and handgrip is 0.004 kg·m2. This is the first standardized myohaptic instrument allowing the dynamic characterization of wrist properties, including under the condition of artificial damping. We show that cerebellar patients are unable to adapt EMG activities when faced with an increase in damping while performing fast reversal movements. The instrument allows the extraction of an electrophysiological signature of a cerebellar deficit.

  8. 3D surface voxel tracing corrector for accurate bone segmentation.

    PubMed

    Guo, Haoyan; Song, Sicong; Wang, Jinke; Guo, Maozu; Cheng, Yuanzhi; Wang, Yadong; Tamura, Shinichi

    2018-06-18

    For extremely close bones, their boundaries are weak and diffused due to strong interaction between adjacent surfaces. These factors prevent the accurate segmentation of bone structure. To alleviate these difficulties, we propose an automatic method for accurate bone segmentation. The method is based on a consideration of the 3D surface normal direction, which is used to detect the bone boundary in 3D CT images. Our segmentation method is divided into three main stages. Firstly, we consider a surface tracing corrector combined with Gaussian standard deviation [Formula: see text] to improve the estimation of normal direction. Secondly, we determine an optimal value of [Formula: see text] for each surface point during this normal direction correction. Thirdly, we construct the 1D signal and refining the rough boundary along the corrected normal direction. The value of [Formula: see text] is used in the first directional derivative of the Gaussian to refine the location of the edge point along accurate normal direction. Because the normal direction is corrected and the value of [Formula: see text] is optimized, our method is robust to noise images and narrow joint space caused by joint degeneration. We applied our method to 15 wrists and 50 hip joints for evaluation. In the wrist segmentation, Dice overlap coefficient (DOC) of [Formula: see text]% was obtained by our method. In the hip segmentation, fivefold cross-validations were performed for two state-of-the-art methods. Forty hip joints were used for training in two state-of-the-art methods, 10 hip joints were used for testing and performing comparisons. The DOCs of [Formula: see text], [Formula: see text]%, and [Formula: see text]% were achieved by our method for the pelvis, the left femoral head and the right femoral head, respectively. Our method was shown to improve segmentation accuracy for several specific challenging cases. The results demonstrate that our approach achieved a superior accuracy over two state-of-the-art methods.

  9. Tendon-bone graft for tendinous mallet fingers following failed splinting.

    PubMed

    Wang, Le; Zhang, Xu; Liu, Ze; Huang, Xiuge; Zhu, Hongwei; Yu, Yadong

    2013-12-01

    To describe and assess a surgical technique for the treatment of tendinous mallet fingers after failed conservative treatment. From January 2010 to March 2012, 28 tendinous mallet fingers in 28 patients were treated. All patients had greater than 25° extensor lags after 6 to 8 weeks of splinting. Four patients had a second trial of splinting, which also failed. A tendon-bone graft, taken from the extensor carpi radialis brevis and the third metacarpal base, was used for reconstruction. The mean time between the injury and operation was 74 days. The mean preoperative extension lag was 34°. Five patients reported pain in the distal interphalangeal joint. At the final follow-up, patients rated the level of pain on the distal interphalangeal and wrist joints using a visual analog scale. Joint motion was graded with the Crawford criteria. Hand function was assessed with the Disabilities of the Arm, Shoulder, and Hand questionnaire. Patients reported on their satisfaction based on the Michigan Hand Outcomes Questionnaire. Bone healing was achieved in all patients at a mean of 5 weeks. Position of bone graft was maintained until bone healing was evident in all cases. At the mean follow-up period of 15 months, nail deformity was not noted. No patient reported pain on the distal interphalangeal joint or wrist. The mean residual extension lag of the distal interphalangeal joints was 4°. The results showed that 24 digits were excellent and 4 were good based on the Crawford criteria. The Disabilities of the Arm, Shoulder, and Hand scores averaged 1, and 27 patients were satisfied with appearance of the hand. One patient sometimes felt uncomfortable regarding the appearance. A tendon-bone graft is a useful and reliable technique for the treatment of tendinous mallet fingers after failed splinting. Therapeutic IV. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  10. Does the type of somatosensory information from the contralateral finger touch affect grip force control while lifting an object?

    PubMed

    Chen, Bing; Aruin, Alexander S

    2013-11-27

    The magnitude of grip force used to lift and transport a hand-held object is decreased if a light finger touch from the contralateral arm is provided to the wrist of the target arm. We investigated whether the type of contralateral arm sensory input that became available with the finger touch to the target arm affects the way grip force is reduced. Nine healthy subjects performed the same task of lifting and transporting an instrumented object with no involvement of the contralateral arm and when an index finger touch of the contralateral arm was provided to the wrist, elbow, and shoulder. Touching the wrist and elbow involved movements of the contralateral arm; no movements were produced while touching the shoulder. Grip force was reduced by approximately the same amount in all conditions with the finger touch compared to the no touch condition. This suggests that information from the muscle and joint receptors of the contralateral arm is used in control of grip force when a finger touch is provided to the wrist and elbow, and cutaneous information is utilized when lifting an object while touching the shoulder. The results of the study provide additional evidence to support the use of a second arm in the performance of activities of daily living and stress the importance of future studies investigating contralateral arm sensory input in grip force control. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  11. The Takei Handheld Dynamometer: An Effective Clinical Outcome Measure Tool for Hand and Wrist Function in Boxing.

    PubMed

    Gatt, Ian; Smith-Moore, Sophie; Steggles, Charlie; Loosemore, Mike

    2018-05-01

    The aim of this article was to explore retrospectively the Takei dynamometer as a valid and reliable outcome measure tool for hand and wrist pathology in the Great Britain amateur boxing squad between 2010 and 2014. Longitudinal retrospective injury surveillance of the Great Britain boxing squad was performed from 2010 to 2014. The location, region affected, description, and duration of each injury were recorded by the team doctor and team physiotherapists. For each significant injury, we recorded hand grip scores using the Takei handheld dynamometer and compared the scores with baseline measures. At the hand, fractures and dislocations were highly detected with an average difference of 40.2% ( P < .05) when comparing postinjury to baseline measures. At the wrist, carpometacarpal and carpal joint injuries were highly detected with an average difference of 32.6% ( P < .05). Other injuries provided varied results. In the absence of pathology, up to 15% difference between left and right scores can be considered normal with a predominance observed below 10%. A difference of 20% can be indicative of a form of pathology, although pathologies can also be present with lower difference or no apparent changes. A difference of >20% should be highly considered for significant pathology. The Takei dynamometer is a valid and reliable outcome measure tool for hand and wrist pathologies in boxing. Our study highlights the importance of appropriate clinical tools to guide injury management in this sport.

  12. Impaired limb position sense after stroke: a quantitative test for clinical use.

    PubMed

    Carey, L M; Oke, L E; Matyas, T A

    1996-12-01

    A quantitative measure of wrist position sense was developed to advance clinical measurement of proprioceptive limb sensibility after stroke. Test-retest reliability, normative standards, and ability to discriminate impaired and unimpaired performance were investigated. Retest reliability was assessed over three sessions, and a matched-pairs study compared stroke and unimpaired subjects. Both wrists were tested, in counterbalanced order. Patients were tested in hospital-based rehabilitation units. Reliability was investigated on a consecutive sample of 35 adult stroke patients with a range of proprioceptive discrimination abilities and no evidence of neglect. A consecutive sample of 50 stroke patients and convenience sample of 50 healthy volunteers, matched for age, sex, and hand dominance, were tested in the normative-discriminative study. Age and sex were representative of the adult stroke population. The test required matching of imposed wrist positions using a pointer aligned with the axis of movement and a protractor scale. The test was reliable (r = .88 and .92) and observed changes of 8 degrees can be interpreted, with 95% confidence, as genuine. Scores of healthy volunteers ranged from 3.1 degrees to 10.9 degrees average error. The criterion of impairment was conservatively defined as 11 degrees (+/-4.8 degrees) average error. Impaired and unimpaired performance were well differentiated. Clinicians can confidently and quantitatively sample one aspect of proprioceptive sensibility in stroke patients using the wrist position sense test. Development of tests on other joints using the present approach is supported by our findings.

  13. Nikolaus Rüdinger (1832-1896), His Description of Joint Innervation in 1857, and the History of Surgical Joint Denervation.

    PubMed

    Gohritz, Andreas; Kaiser, Erich; Guggenheim, Merlin; Dellon, Arnold Lee

    2018-01-01

     Selective joint denervation has become a reliable palliative treatment, especially for painful joints in the upper and lower extremity.  This article highlights the life and work of Nikolaus Rüdinger (1832-1896) who first described joint innervation which became the basis of later techniques of surgical joint denervation. The historical evolution of this method is outlined.  Rüdinger made a unique career from apprentice barber to military surgeon and anatomy professor in Munich, Germany. His first description of articular innervation of temporomandibular, shoulder, elbow, wrist, finger, sacroiliac, hip, knee, ankle, foot, and toe joints in 1857 stimulated the subsequent history of surgical joint denervation. Comparing his investigations with modern joint denervation methods, developed by pioneers like Albrecht Wilhelm or A. Lee Dellon, shows his great exactitude and anatomical correspondence despite different current terminology. Clinical series of modern surgical joint denervations reveal success rates of up to 80% with reliable long-term results.  The history of joint denervation with Rüdinger as its important protagonist offers inspiring insights into the evolution of surgical techniques and exemplifies the value of descriptive functional anatomy, even if surgical application may not have been realized until a century later. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  14. Dynamic analysis of astronaut motions in microgravity: Applications for Extravehicular Activity (EVA)

    NASA Technical Reports Server (NTRS)

    Newman, Dava J.

    1995-01-01

    Simulations of astronaut motions during extravehicular activity (EVA) tasks were performed using computational multibody dynamics methods. The application of computational dynamic simulation to EVA was prompted by the realization that physical microgravity simulators have inherent limitations: viscosity in neutral buoyancy tanks; friction in air bearing floors; short duration for parabolic aircraft; and inertia and friction in suspension mechanisms. These limitations can mask critical dynamic effects that later cause problems during actual EVA's performed in space. Methods of formulating dynamic equations of motion for multibody systems are discussed with emphasis on Kane's method, which forms the basis of the simulations presented herein. Formulation of the equations of motion for a two degree of freedom arm is presented as an explicit example. The four basic steps in creating the computational simulations were: system description, in which the geometry, mass properties, and interconnection of system bodies are input to the computer; equation formulation based on the system description; inverse kinematics, in which the angles, velocities, and accelerations of joints are calculated for prescribed motion of the endpoint (hand) of the arm; and inverse dynamics, in which joint torques are calculated for a prescribed motion. A graphical animation and data plotting program, EVADS (EVA Dynamics Simulation), was developed and used to analyze the results of the simulations that were performed on a Silicon Graphics Indigo2 computer. EVA tasks involving manipulation of the Spartan 204 free flying astronomy payload, as performed during Space Shuttle mission STS-63 (February 1995), served as the subject for two dynamic simulations. An EVA crewmember was modeled as a seven segment system with an eighth segment representing the massive payload attached to the hand. For both simulations, the initial configuration of the lower body (trunk, upper leg, and lower leg) was a neutral microgravity posture. In the first simulation, the payload was manipulated around a circular trajectory of 0.15 m radius in 10 seconds. It was found that the wrist joint theoretically exceeded its ulnal deviation limit by as much as 49. 8 deg and was required to exert torques as high as 26 N-m to accomplish the task, well in excess of the wrist physiological limit of 12 N-m. The largest torque in the first simulation, 52 N-m, occurred in the ankle joint. To avoid these problems, the second simulation placed the arm in a more comfortable initial position and the radius and speed of the circular trajectory were reduced by half. As a result, the joint angles and torques were reduced to values well within their physiological limits. In particular, the maximum wrist torque for the second simulation was only 3 N-m and the maximum ankle torque was only 6 N-m.

  15. A hybrid BMI-based exoskeleton for paresis: EMG control for assisting arm movements

    NASA Astrophysics Data System (ADS)

    Kawase, Toshihiro; Sakurada, Takeshi; Koike, Yasuharu; Kansaku, Kenji

    2017-02-01

    Objective. Brain-machine interface (BMI) technologies have succeeded in controlling robotic exoskeletons, enabling some paralyzed people to control their own arms and hands. We have developed an exoskeleton asynchronously controlled by EEG signals. In this study, to enable real-time control of the exoskeleton for paresis, we developed a hybrid system with EEG and EMG signals, and the EMG signals were used to estimate its joint angles. Approach. Eleven able-bodied subjects and two patients with upper cervical spinal cord injuries (SCIs) performed hand and arm movements, and the angles of the metacarpophalangeal (MP) joint of the index finger, wrist, and elbow were estimated from EMG signals using a formula that we derived to calculate joint angles from EMG signals, based on a musculoskeletal model. The formula was exploited to control the elbow of the exoskeleton after automatic adjustments. Four able-bodied subjects and a patient with upper cervical SCI wore an exoskeleton controlled using EMG signals and were required to perform hand and arm movements to carry and release a ball. Main results. Estimated angles of the MP joints of index fingers, wrists, and elbows were correlated well with the measured angles in 11 able-bodied subjects (correlation coefficients were 0.81  ±  0.09, 0.85  ±  0.09, and 0.76  ±  0.13, respectively) and the patients (e.g. 0.91  ±  0.01 in the elbow of a patient). Four able-bodied subjects successfully positioned their arms to adequate angles by extending their elbows and a joint of the exoskeleton, with root-mean-square errors  <6°. An upper cervical SCI patient, empowered by the exoskeleton, successfully carried a ball to a goal in all 10 trials. Significance. A BMI-based exoskeleton for paralyzed arms and hands using real-time control was realized by designing a new method to estimate joint angles based on EMG signals, and these may be useful for practical rehabilitation and the support of daily actions.

  16. A hybrid BMI-based exoskeleton for paresis: EMG control for assisting arm movements.

    PubMed

    Kawase, Toshihiro; Sakurada, Takeshi; Koike, Yasuharu; Kansaku, Kenji

    2017-02-01

    Brain-machine interface (BMI) technologies have succeeded in controlling robotic exoskeletons, enabling some paralyzed people to control their own arms and hands. We have developed an exoskeleton asynchronously controlled by EEG signals. In this study, to enable real-time control of the exoskeleton for paresis, we developed a hybrid system with EEG and EMG signals, and the EMG signals were used to estimate its joint angles. Eleven able-bodied subjects and two patients with upper cervical spinal cord injuries (SCIs) performed hand and arm movements, and the angles of the metacarpophalangeal (MP) joint of the index finger, wrist, and elbow were estimated from EMG signals using a formula that we derived to calculate joint angles from EMG signals, based on a musculoskeletal model. The formula was exploited to control the elbow of the exoskeleton after automatic adjustments. Four able-bodied subjects and a patient with upper cervical SCI wore an exoskeleton controlled using EMG signals and were required to perform hand and arm movements to carry and release a ball. Estimated angles of the MP joints of index fingers, wrists, and elbows were correlated well with the measured angles in 11 able-bodied subjects (correlation coefficients were 0.81  ±  0.09, 0.85  ±  0.09, and 0.76  ±  0.13, respectively) and the patients (e.g. 0.91  ±  0.01 in the elbow of a patient). Four able-bodied subjects successfully positioned their arms to adequate angles by extending their elbows and a joint of the exoskeleton, with root-mean-square errors  <6°. An upper cervical SCI patient, empowered by the exoskeleton, successfully carried a ball to a goal in all 10 trials. A BMI-based exoskeleton for paralyzed arms and hands using real-time control was realized by designing a new method to estimate joint angles based on EMG signals, and these may be useful for practical rehabilitation and the support of daily actions.

  17. Trauma Pod/Operating Room of the Future

    DTIC Science & Technology

    2006-02-01

    into C++ objects. OpenBinder software provided by ORNL was also used. This approach reduces the potential errors that might be introduced by...publications can be found here. OSCAR has been used by developers at the Univ. of Texas, ORNL , NASA/Ames, and NASA/JSC. RRGKinematix, a single...the last DH frame (at the wrist) is 70 mm. Position Travel Limits (degrees) - these are software limits as specified by ORNL Joint 1

  18. Disruption of spatial organization and interjoint coordination in Parkinson's disease, progressive supranuclear palsy, and multiple system atrophy.

    PubMed

    Leiguarda, R; Merello, M; Balej, J; Starkstein, S; Nogues, M; Marsden, C D

    2000-07-01

    Patients with basal ganglia diseases may exhibit ideomotor apraxia. To define the nature of the impairment of the action production system, we studied a repetitive gesture of slicing bread by three-dimensional computergraphic analysis in eight nondemented patients with Parkinson's disease in the "on" state, five with progressive supranuclear palsy and four with multiple system atrophy. Two patients with Parkinson's disease and two with progressive supranuclear palsy showed ideomotor apraxia for transitive movements on standard testing. A Selspott II system was used for kinematic analysis of wrist trajectories and angular motions of the shoulder and elbow joints. Patients with Parkinson's disease, progressive supranuclear palsy, and even some with multiple system atrophy exhibited kinematic deficits in the spatial precision of movement and velocity-curvature relationships; in addition, they failed to maintain proper angle/angle relationships and to apportion their relative joint amplitudes normally. Spatial disruption of wrist trajectories was more severe in patients with ideomotor apraxia. We posit that the basal ganglia are part of the parallel parieto-frontal circuits devoted to sensorimotor integration for object-oriented behavior. The severity and characteristics of spatial abnormalities of a transitive movement would therefore depend on the location and distribution of the pathologic process within these circuits.

  19. Reconstruction of the elbow and forearm for Ewing sarcoma of ulna: A new biological technique

    PubMed Central

    Puri, Ajay; Gulia, Ashish; Byregowda, Suman; Ramanujan, Vishnu

    2016-01-01

    Primary bone tumors around the elbow represent <1% of all the skeletal tumors. Surgery with or without adjuvant therapy (radiotherapy, chemotherapy) is the treatment of choice for malignant tumors. Reconstruction of the elbow and forearm in malignant tumors is challenging as it involves a complex interplay between multiple joints which need to be stabilized for the optimal functional outcome. We describe a new technique for the reconstruction of the elbow after resection of a proximal ulna tumor with articular radio-ulnar synostosis with the creation of a single bone forearm. We attempted to achieve a mobile elbow and stable wrist joint with the radio-ulnar union at the proximal articular surface of the ulna resulting in a single bone forearm. The procedure involves an oblique osteotomy preserving the olecranon process (after taking adequate margins based on oncological principles) and its articular cartilage along with the attachment of the triceps tendon. Then the radial head was partially denuded of its cartilage using a burr, leaving cartilage only on the volar side, and then fused to the remnant olecranon. Osteosynthesis was done using compression screw and tension band wiring. The advantages of this procedure are that the mobility at wrist and elbow are retained, it requires minimal hardware and allows for primary closure of the wound. PMID:27186061

  20. Extensor Tendon Injuries and Repairs in the Hand

    PubMed Central

    Kontor, J. A.

    1982-01-01

    Due to their superficial course, the extensor tendons are frequently lacerated over the dorsum of the hand and fingers. Excellent functional results are obtained in repairs of simple tendon lacerations. ‘Open’ mallet lacerations over the distal IP joint or involving the central extensor slip over the proximal IP joint require more precise suturing methods. More proximal extensor tendon divisions near the wrist involve dissection of the retracted finger extensors or long thumb extensor in the distal forearm and more formal tendon repairs, including a possible tendon transfer to the thumb. ‘Closed injuries’, with varying degrees of extensor tendon disruption, occur at three main sites. The mallet injury at the DIP joint and the boutonnière deformity over the PIP joint are sometimes recognized late, but respond to conservative splinting for a minimum of four weeks with guarded motion avoiding secondary stiffening of the remaining small joints of the hand. Surgery of closed injuries most frequently involves the intra-articular traction fracture type of mallet deformities in which the DIP joint has taken the brunt of the injury. PMID:21286174

  1. Time Independent Functional task Training: a case study on the effect of inter-joint coordination driven haptic guidance in stroke therapy.

    PubMed

    Brokaw, Elizabeth B; Murray, Theresa M; Nef, Tobias; Lum, Peter S; Brokaw, Elizabeth B; Nichols, Diane; Holley, Rahsaan J

    2011-01-01

    After a stroke abnormal joint coordination of the arm may limit functional movement and recovery. To aid in training inter-joint movement coordination a haptic guidance method for functional driven rehabilitation after stroke called Time Independent Functional Training (TIFT) has been developed for the ARMin III robot. The mode helps retraining inter-joint coordination during functional movements, such as putting an object on a shelf, pouring from a pitcher, and sorting objects into bins. A single chronic stroke subject was tested for validation of the modality. The subject was given 1.5 hrs of robotic therapy twice a week for 4 weeks. The therapy and the results of training the single stroke subject are discussed. The subject showed a decrease in training joint error for the sorting task across training sessions and increased self-selected movement time in training. In kinematic reaching analysis the subject showed improvements in range of motion and joint coordination in a reaching task, as well as improvements in supination-pronation range of motion at the wrist. © 2011 IEEE

  2. Determining early referral criteria for patients with suspected inflammatory arthritis presenting to primary care physicians: a cross-sectional study.

    PubMed

    Almoallim, Hani; Janoudi, Nahid; Attar, Suzan M; Garout, Mohammed; Algohary, Shereen; Siddiqui, Muhammad Irfanullah; Alosaimi, Hanan; Ibrahim, Ashraf; Badokhon, Amira; Algasemi, Zaki

    2017-01-01

    Early diagnosis and initiation of treatment for inflammatory arthritis can greatly improve patient outcome. We aimed to provide standardized and validated criteria for use by primary care physicians (PCPs) in the identification of individuals requiring referral to a rheumatologist. We analyzed the predictive value of a wide variety of demographic variables, patient-reported complaints, physical examination results, and biomarkers in order to identify the most useful factors for indicating a requirement for referral. Patients for this cross-sectional study were enrolled from various centers of the city of Jeddah, Saudi Arabia, if they were ≥18 years of age and presented to a PCP with small joint pain that had been present for more than 6 weeks. A total of 203 patients were enrolled, as indicated by the sample size calculation. Each patient underwent a standardized physical examination, which was subsequently compared to ultrasound findings. Biomarker analysis and a patient interview were also carried out. Results were then correlated with the final diagnosis made by a rheumatologist. A total of 9 variables were identified as having high specificity and good predictive value: loss of appetite, swelling of metacarpophalangeal joint 2 or 5, swelling of proximal inter-phalangeal joint 2 or 3, wrist swelling, wrist tenderness, a positive test for rheumatoid factor, and a positive test for anti-citrullinated protein antibodies. Nine variables should be the basis of early referral criteria. It should aid PCPs in making appropriate early referrals of patients with suspected inflammatory arthritis, accelerating diagnosis and initiation of treatment.

  3. Exoskeletal meal assistance system (EMAS II) for progressive muscle dystrophy patient.

    PubMed

    Hasegawa, Yasuhisa; Oura, Saori

    2011-01-01

    This paper introduces a 4-DOFs exoskeletal meal assistance system (EMAS II) for progressive muscle dystrophy patient. It is generally better for the patient to use his/her hands by himself in daily life because active works maintain level of residual functions, health and initiative of him/her. The EMAS II that has a new joystick-type user interface device and three-DOFs on a shoulder part is enhanced for an easier operation and more comfortable support on eating, as the succeeding model of the previous system that has two-DOFs on a shoulder. In order to control the 4-DOFs system by the simple user interface device, the EMAS II simulates upper limb motion patterns of a healthy person. The motion patterns are modeled by extracting correlations between the height of a user's wrist joint and that of the user's elbow joint at the table. Moreover, the EMAS II automatically brings user's hand up to his/her mouth or back to a table when he/she pushes a preset switch on the interface device. Therefore a user has only to control a position of his/her wrist to pick or scoop foods and then flip the switch to start automatic mode, while a height of the elbow joint is automatically controlled by the EMAS II itself. The results of experiments, where a healthy subject regarded as a muscle dystrophy patient eats a meal with EMAS II, show that the subject finished her meal in a natural way in 18 minutes 40 seconds which was within a recommended time of 30 minutes. © 2011 IEEE

  4. Low-frequency periodicity in the coordination of progressive handwriting.

    PubMed

    Thomassen, A J; Meulenbroek, R G

    1998-11-01

    The paper addresses the question how the effector segments are coordinated during handwriting, in particular as a function of the left-to-right progression within words. It studies the phase relations between wrist and finger-joint rotations during a repetitive graphic task (long words consisting of letters 'e'), and it subjects the resulting continuous phase-relation plots to autocorrelation analysis. A novel phenomenon, viz. that of low-frequency (1-Hz) periodicity, is observed which presumably reflects adjustments of the coordination pattern about once per second, i.e., after every three or four letters 'e'. Moreover, word length and word position are found to affect this periodicity in a predictable manner. These results are related to those of an earlier study which used an ad-hoc method of analysing wrist-finger coordination adjustments. The paper underlines the value of phase-relation analysis for certain graphic tasks, but it also points out its limitations for this purpose.

  5. A Case of Trapezium Avascular Necrosis Treated Conservatively.

    PubMed

    Petsatodis, Evangelos; Ditsios, Konstantinos; Konstantinou, Panagiotis; Pinto, Iosafat; Kostretzis, Lazaros; Theodoroudis, Ioannis; Pilavaki, Mayia

    2017-01-01

    Avascular necrosis (AVN) of the bones of the wrist most commonly involves the lunate followed by the proximal pole of the scaphoid and the capitate. Trapezium avascular necrosis is extremely rare with only two cases reported in the literature, both of which were treated surgically. In this article, we report a unique case of trapezium avascular necrosis treated conservatively. A 38-year-old man complaining of a 4-month history of mild pain on the base of his right thumb. MRI scan was performed. The clinical presentation and the imaging findings indicated avascular osteonecrosis of the trapezium. The patient was treated with immobilization of the wrist joint for a period of six weeks. Three months later, the patient was free of symptoms and the MRI scan revealed a normal trapezium. AVN of trapezium is extremely rare. Our case shows that immobilization of an early stage avascular necrosis of the trapezium might be a treatment option.

  6. [Effect of pneumatic compression in connection with ergotherapeutic treatment of Colles' fracture. A clinical controlled trial].

    PubMed

    Svensson, B H; Frellsen, M B; Basse, P N; Bliddal, H; Caspers, J; Parby, K

    1993-02-15

    We followed forty women with functional deficits in the wrist and hand after sustaining a Colles' fracture. The women participated in occupational therapy three times a week for three weeks. At the initial evaluation, after three weeks, and at a three month evaluation, we measured the following: range of joint movement, grip strength, hand volume (oedema), pain and ADL. There was significant improvement in most of the parameters measured after three weeks of occupational therapy, with a less significant improvement from three weeks to three months. Seventeen of the forty women received twenty minutes of intermittent pneumatic compression before occupational therapy. These patients showed significant improvement in wrist extension, compared with the control group of twenty-three patients. Occupational therapy is recommended for patients showing a functional deficit after Colles' fracture. Intermittent pneumatic compression is recommended as a supplement to occupational therapy.

  7. Intraoperative extracorporeal autogenous irradiated tendon grafts for functional limb salvage surgery of soft tissue sarcomas of the wrist and hand.

    PubMed

    Omori, Shinsuke; Hamada, Kenichiro; Outani, Hidetatsu; Oshima, Kazuya; Joyama, Susumu; Tomita, Yasuhiko; Naka, Norifumi; Araki, Nobuhito; Yoshikawa, Hideki

    2015-05-12

    In patients with soft tissue sarcoma of the wrist and hand, limb salvage operation is extremely challenging for surgeons in attempting a complete tumor resection with negative surgical margins. In this study, we report four patients with soft tissue sarcoma of the wrist and hand treated by limb salvage operation with intraoperative extracorporeal autogenous irradiated tendon grafts. The patients were all male, and the mean age at the time of surgery was 45 years. Histological diagnoses included clear cell sarcoma in two patients, synovial sarcoma in one, and angiosarcoma in one. All four patients had high grade tumors, wherein three had American Joint Committee on Cancer (AJCC) stage III disease and one with AJCC stage IV disease. The tumors were resected en bloc with involved tendons. The tendons were isolated from the resected tissues, irradiated ex vivo, and re-implanted into the host tendons. In one patient, the bone was resected additionally because of tumor invasion to the bone. Hand function was evaluated using Musculoskeletal Tumor Society (MSTS) rating system. Of the four patients, three died of distant metastatic disease. The remaining patient lives and remains disease-free. The mean follow-up period was 33 months. One patient had local recurrence outside the irradiated graft at 20 months after surgery. The functional rating was 22. Lower scores were seen in patients with reconstruction of flexor tendons than extensor tendons. Limb salvage operation with intraoperative extracorporeal autogenous irradiated tendon grafts is an acceptable method in selected patients with soft tissue sarcoma of the wrist and hand.

  8. Septic arthritis due to tubercular and Aspergillus co-infection

    PubMed Central

    Kumar, Mukesh; Thilak, Jai; Zahoor, Adnan; Jyothi, Arun

    2016-01-01

    Aspergillus septic arthritis is a rare and serious medical and surgical problem. It occurs mainly in immunocompromised patients. Aspergillus fumigatus is the most common causative organism followed by Aspergillus flavus. The most common site affected is knee followed by shoulder, ankle, wrist, hip and sacroiliac joint. Debridement and voriconazole are primary treatment of articular aspergilosis. To the best of our knowledge, there are no reported cases of co-infection of tuberculosis (TB) and Aspergillus infecting joints. We report a case of co-infection of TB and A. flavus of hip and knee of a 60-year-old male, with type 2 diabetes mellitus. He was treated with debridement, intravenous voriconazole, and antitubercular drugs. PMID:27293296

  9. Septic arthritis due to tubercular and Aspergillus co-infection.

    PubMed

    Kumar, Mukesh; Thilak, Jai; Zahoor, Adnan; Jyothi, Arun

    2016-01-01

    Aspergillus septic arthritis is a rare and serious medical and surgical problem. It occurs mainly in immunocompromised patients. Aspergillus fumigatus is the most common causative organism followed by Aspergillus flavus. The most common site affected is knee followed by shoulder, ankle, wrist, hip and sacroiliac joint. Debridement and voriconazole are primary treatment of articular aspergilosis. To the best of our knowledge, there are no reported cases of co-infection of tuberculosis (TB) and Aspergillus infecting joints. We report a case of co-infection of TB and A. flavus of hip and knee of a 60-year-old male, with type 2 diabetes mellitus. He was treated with debridement, intravenous voriconazole, and antitubercular drugs.

  10. Estimation of Energy Expenditure for Wheelchair Users Using a Physical Activity Monitoring System.

    PubMed

    Hiremath, Shivayogi V; Intille, Stephen S; Kelleher, Annmarie; Cooper, Rory A; Ding, Dan

    2016-07-01

    To develop and evaluate energy expenditure (EE) estimation models for a physical activity monitoring system (PAMS) in manual wheelchair users with spinal cord injury (SCI). Cross-sectional study. University-based laboratory environment, a semistructured environment at the National Veterans Wheelchair Games, and the participants' home environments. Volunteer sample of manual wheelchair users with SCI (N=45). Participants were asked to perform 10 physical activities (PAs) of various intensities from a list. The PAMS consists of a gyroscope-based wheel rotation monitor (G-WRM) and an accelerometer device worn on the upper arm or on the wrist. Criterion EE using a portable metabolic cart and raw sensor data from PAMS were collected during each of these activities. Estimated EE using custom models for manual wheelchair users based on either the G-WRM and arm accelerometer (PAMS-Arm) or the G-WRM and wrist accelerometer (PAMS-Wrist). EE estimation performance for the PAMS-Arm (average error ± SD: -9.82%±37.03%) and PAMS-Wrist (-5.65%±32.61%) on the validation dataset indicated that both PAMS-Arm and PAMS-Wrist were able to estimate EE for a range of PAs with <10% error. Moderate to high intraclass correlation coefficients (ICCs) indicated that the EE estimated by PAMS-Arm (ICC3,1=.82, P<.05) and PAMS-Wrist (ICC3,1=.89, P<.05) are consistent with the criterion EE. Availability of PA monitors can assist wheelchair users to track PA levels, leading toward a healthier lifestyle. The new models we developed can estimate PA levels in manual wheelchair users with SCI in laboratory and community settings. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  11. An Exoskeleton Robot for Human Forearm and Wrist Motion Assist

    NASA Astrophysics Data System (ADS)

    Ranathunga Arachchilage Ruwan Chandra Gopura; Kiguchi, Kazuo

    The exoskeleton robot is worn by the human operator as an orthotic device. Its joints and links correspond to those of the human body. The same system operated in different modes can be used for different fundamental applications; a human-amplifier, haptic interface, rehabilitation device and assistive device sharing a portion of the external load with the operator. We have been developing exoskeleton robots for assisting the motion of physically weak individuals such as elderly or slightly disabled in daily life. In this paper, we propose a three degree of freedom (3DOF) exoskeleton robot (W-EXOS) for the forearm pronation/ supination motion, wrist flexion/extension motion and ulnar/radial deviation. The paper describes the wrist anatomy toward the development of the exoskeleton robot, the hardware design of the exoskeleton robot and EMG-based control method. The skin surface electromyographic (EMG) signals of muscles in forearm of the exoskeletons' user and the hand force/forearm torque are used as input information for the controller. By applying the skin surface EMG signals as main input signals to the controller, automatic control of the robot can be realized without manipulating any other equipment. Fuzzy control method has been applied to realize the natural and flexible motion assist. Experiments have been performed to evaluate the proposed exoskeleton robot and its control method.

  12. Polish Adaptation of Wrist Evaluation Questionnaires.

    PubMed

    Czarnecki, Piotr; Wawrzyniak-Bielęda, Anna; Romanowski, Leszek

    2015-01-01

    Questionnaires evaluating hand and wrist function are a very useful tool allowing for objective and systematic recording of symptoms reported by the patients. Most questionnaires generally accepted in clinical practice are available in English and need to be appropriately adapted in translation and undergo subsequent validation before they can be used in another culture and language. The process of translation of the questionnaires was based on the generally accepted guidelines of the International Quality of Life Assessment Project (IQOLA). First, the questionnaires were translated from English into Polish by two independent translators. Then, a joint version of the translation was prepared collectively and translated back into English. Each stage was followed by a written report. The translated questionnaires were then evaluated by a group of patients. We selected 31 patients with wrist problems and asked them to complete the PRWE, Mayo, Michigan and DASH questionnaires twice at intervals of 3-10 days. The results were submitted for statistical analysis. We found a statistically significant (p<0.05) correlation for the two completions of the questionnaires. A comparison of the PRWE and Mayo questionnaires with the DASH questionnaire also showed a statistically significant correlation (p<0.05). Our results indicate that the cultural adaptation of the translated questionnaires was successful and that the questionnaires may be used in clinical practice.

  13. Actigraphy in the critically ill: correlation with activity, agitation, and sedation.

    PubMed

    Grap, Mary Jo; Borchers, C Todd; Munro, Cindy L; Elswick, R K; Sessler, Curtis N

    2005-01-01

    To determine the feasibility of continuous measurement of limb movement via wrist and ankle actigraphy (an activity measure) in critically ill patients and to compare actigraphy measurements with observed activity, subjective scores on sedation-agitation scales, and heart rate and blood pressure of patients. In a prospective, descriptive, correlational study, all activity of 20 adult patients in medical and coronary care units in a university medical center were observed for 2 hours and documented. Wrist and ankle actigraphy, heart rate, and systolic and diastolic blood pressure data were collected every minute. The Comfort Scale and the Richmond Agitation-Sedation Scale were completed at the beginning of the observation period and 1 and 2 hours later. Wrist actigraphy data correlated with scores on the Richmond Agitation-Sedation Scale (r = 0.58) and the Comfort Scale (r = 0.62) and with observed stimulation and activity events of patients (r = 0.45). Correlations with systolic, diastolic, and mean arterial pressures were weaker. Wrist and ankle actigraphy data were significantly correlated (r = 0.69; P < .001); however, their mean values (wrist, 418; ankle, 147) were significantly different (t = 5.77; P < .001). Actigraphy provides a continuous recording of patients' limb movement. Actigraphy measurements correlate well with patients' observed activity and with subjective scores on agitation and sedation scales. Actigraphy may become particularly important as a continuous measurement of activity for use in behavioral research and may enhance early recognition and management of the excessive activity that characterizes agitation.

  14. The validation of a human force model to predict dynamic forces resulting from multi-joint motions

    NASA Technical Reports Server (NTRS)

    Pandya, Abhilash K.; Maida, James C.; Aldridge, Ann M.; Hasson, Scott M.; Woolford, Barbara J.

    1992-01-01

    The development and validation is examined of a dynamic strength model for humans. This model is based on empirical data. The shoulder, elbow, and wrist joints were characterized in terms of maximum isolated torque, or position and velocity, in all rotational planes. This data was reduced by a least squares regression technique into a table of single variable second degree polynomial equations determining torque as a function of position and velocity. The isolated joint torque equations were then used to compute forces resulting from a composite motion, in this case, a ratchet wrench push and pull operation. A comparison of the predicted results of the model with the actual measured values for the composite motion indicates that forces derived from a composite motion of joints (ratcheting) can be predicted from isolated joint measures. Calculated T values comparing model versus measured values for 14 subjects were well within the statistically acceptable limits and regression analysis revealed coefficient of variation between actual and measured to be within 0.72 and 0.80.

  15. Directional tuning of human forearm muscle afferents during voluntary wrist movements

    PubMed Central

    Jones, Kelvin E; Wessberg, Johan; Vallbo, Åke B

    2001-01-01

    Single unit activity was recorded with the microneurography technique from sixteen spindle afferents and one Golgi tendon organ afferent originating from the forearm extensor muscles. Impulse rates were studied while subjects performed unobstructed aiming movements at the wrist in eight different directions 45 deg apart. In addition, similar imposed movements were performed while the subject was instructed to remain relaxed. Movement amplitudes were about 5 deg and the speed 10–30 deg s−1. Joint movements were translated to movements of a cursor on a monitor to provide visual feedback. Individual spindle afferents modulated their activity over a number of targets, i.e. were broadly tuned, during these aiming movements. The preferred direction for a spindle afferent was the same during both passive and active movements, indicating that the fusimotor effects associated with active contractions had little or no effect on the direction of tuning. The direction of tuning of individual spindle afferents could be predicted from the biomechanically inferred length changes of the parent muscle. Thus spindle afferents responded as stretch receptors, i.e. impulse rates increased with lengthening and decreased with shortening, in active as well as passive movements. Spindles from muscles, which continuously counteracted gravity exhibited a stretch response and directional tuning during the phase of movement alone whereas their position sensitivity was poor. In contrast, spindle afferents from the muscles that had no or minimal antigravity role were directionally tuned during both the dynamic and the static phase of the aiming task and their position sensitivity was substantially higher. In spite of the limited data base from three extensor muscles it could be demonstrated that wrist joint position was remarkably well encoded in the ensemble muscle spindle data. In some cases the ensemble muscle spindle data encoded the instantaneous trajectory of movement as well. PMID:11600696

  16. Shoulder pain and jerk during recovery phase of manual wheelchair propulsion.

    PubMed

    Jayaraman, Chandrasekaran; Beck, Carolyn L; Sosnoff, Jacob J

    2015-11-05

    Repetitive loading of the upper limb due to wheelchair propulsion plays a leading role in the development of shoulder pain in manual wheelchair users (mWCUs). There has been minimal inquiry on understanding wheelchair propulsion kinematics from a human movement ergonomics perspective. This investigation employs an ergonomic metric, jerk, to characterize the recovery phase kinematics of two recommended manual wheelchair propulsion patterns: semi-circular and the double loop. Further it examines if jerk is related to shoulder pain in mWCUs. Data from 22 experienced adult mWCUs was analyzed for this study (semi-circular: n=12 (pain/without-pain:6/6); double-loop: n=10 (pain/without-pain:4/6)). Participants propelled their own wheelchair fitted with SMARTWheels on a roller dynamometer at 1.1 m/s for 3 min. Kinematic and kinetic data of the upper limbs were recorded. Three dimensional absolute jerk experienced at the shoulder, elbow and wrist joint during the recovery phase of wheelchair propulsion were computed. Two-way ANOVAs were conducted with the recovery pattern type and shoulder pain as between group factors. (1) Individuals using a semi-circular pattern experienced lower jerk at their arm joints than those using a double loop pattern (P<0.05, η(2)=0.32)wrist;(P=0.05, η(2)=0.19)elbow;(P<0.05, η(2)=0.34)shoulder and (2) individuals with shoulder pain had lower peak jerk magnitude during the recovery phase (P≤0.05, η(2)=0.36)wrist;(P≤0.05, η(2)=0.30)elbow;(P≤0.05, η(2)=0.31)shoulder. Jerk during wheelchair propulsion was able to distinguish between pattern types (semi-circular and double loop) and the presence of shoulder pain. Jerk provides novel insights into wheelchair propulsion kinematics and in the future it may be beneficial to incorporate jerk based metric into rehabilitation practice. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Shoulder pain and jerk during recovery phase of manual wheelchair propulsion

    PubMed Central

    Jayaraman, Chandrasekaran; Beck, Carolyn L; Sosnoff, Jacob J.

    2015-01-01

    Repetitive loading of the upper limb due to wheelchair propulsion plays a leading role in the development of shoulder pain in manual wheelchair users (mWCUs). There has been minimal inquiry on understanding wheelchair propulsion kinematics from a human movement ergonomics perspective. This investigation employs an ergonomic metric, jerk, to characterize the recovery phase kinematics of two recommended manual wheelchair propulsion patterns: semi-circular and the double loop. Further it examines if jerk is related to shoulder pain in mWCUs. Data from 22 experienced adult mWCUs was analyzed for this study (semi-circular: n=12 (pain/without-pain:6/6); double-loop: n=10 (pain/without-pain:4/6)). Participants propelled their own wheelchair fitted with SMARTWheels on a roller dynamometer at 1.1 m/s for 3 minutes. Kinematic and kinetic data of the upper limbs were recorded. Three dimensional absolute jerk experienced at the shoulder, elbow and wrist joint during the recovery phase of wheelchair propulsion were computed. Two-way ANOVAs were conducted with the recovery pattern type and shoulder pain as between group factors. Findings (1) Individuals using a semi-circular pattern experienced lower jerk at their arm joints than those using a double loop pattern (P<0.05, η2=0.32)wrist; (P=0.05, η2=0.19)elbow; (P<0.05, η2=0.34)shoulder and (2) individuals with shoulder pain had lower peak jerk magnitude during the recovery phase (P≤0.05, η2=0.36)wrist; (P≤0.05, η2=0.30)elbow; (P≤0.05, η2=0.31)shoulder. Conclusions Jerk during wheelchair propulsion was able to distinguish between pattern types (semi-circular and double loop) and the presence of shoulder pain. Jerk provides novel insights into wheelchair propulsion kinematics and in the future it may be beneficial to incorporate jerk based metric into rehabilitation practice. PMID:26472307

  18. Postoperative imaging of orthopaedic hardware in the hand and wrist: is there an added value for tomosynthesis?

    PubMed

    De Silvestro, A; Martini, K; Becker, A S; Kim-Nguyen, T D L; Guggenberger, R; Calcagni, M; Frauenfelder, T

    2018-02-01

    To prospectively investigate digital tomosynthesis (DTS) as an alternative to digital radiography (DR) for postoperative imaging of orthopaedic hardware after trauma or arthrodesis in the hand and wrist. Thirty-six consecutive patients (12 female, median age 36 years, range 19-86 years) were included in this institutional review board approved clinical trial. Imaging was performed with DTS in dorso-palmar projection and DR was performed in dorso-palmar, lateral, and oblique views. Images were evaluated by two independent radiologists for qualitative and diagnosis-related imaging parameters using a four-point Likert scale (1=excellent, 4not diagnostic) and nominal scale. Interobserver agreement between the two readers was assessed with Cohen's kappa (k). Differences between DTS and CR were tested with Wilcoxon's signed-rank test. A p-value <0.05 was considered statistically significant. Regarding image quality, interobserver agreement was higher for DTS compared to DR, especially for fracture-related parameters (delineation osteosynthesis material [OSM]: K DTS 0.96 versus K DR 0.45; delineation fracture margins: K DTS 0.78 versus K DR 0.35). Delineation of fracture margins and delineation of adjacent joint spaces scored significant better for DTS compared to DR (delineation fracture margins: DTS1.54, DR2.28, p0.001; delineation adjacent joint spaces: DTS1.31, DR2.24, p0.001). Regarding diagnosis-related findings, interobserver agreement was almost equal. DTS showed a significant higher sharpness of fracture margins (DTS1.94, DR2.33, p0.04). Mean dose area product (DAP) for DTS was significant higher compared to DR (mean DR0.219 Gy·cm 2 , mean DTS0.903 Gy·cm 2 , p0.001). Fracture healing is more visible and interobserver agreement is higher for DTS compared to DR in the postoperative assessment of orthopaedic hardware in the hand and wrist. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  19. A comprehensive musculoskeletal and peripheral nervous system assessment of war-related bilateral upper extremity amputees.

    PubMed

    Allami, Mostafa; Mousavi, Batool; Masoumi, Mehdi; Modirian, Ehsan; Shojaei, Hadi; Mirsalimi, Fatemeh; Hosseini, Maryam; Pirouzi, Pirouz

    2016-01-01

    Upper limb amputations are one of the unpleasant war injuries that armed forces are exposed to frequently. The present study aimed to assess the musculoskeletal and peripheral nervous systems in Iraq-Iran war veterans with bilateral upper extremity amputation. The study consisted of taking a history and clinical examinations including demographic data, presence and location of pain, level of amputation, passive and active ranges of movement of the joints across the upper and lower extremities and spine, manual palpation, neurological examination, blood circulation pulses and issues related to a prosthetic limb. In this study, 103 Iranian bilateral upper extremity amputees (206 amputations) from the Iran-Iraq war were evaluated, and a detailed questionnaire was also administered. The most common level of amputation was the finger or wrist level (108, 52.4 %). Based on clinical examination, we found high frequencies of limited active and passive joint range of movement across the scapula, shoulder, elbow, wrist and metacarpophalangeal, interphalangeal and thumb joints. Based on muscle strength testing, we found varying degrees of weakness across the upper limbs. Musculoskeletal disorders included epicondylitis (65, 31.6 %), rotator cuff injury (24, 11.7 %), bicipital tendonitis (69, 33.5 %), shoulder drop (42, 20.4 %) and muscle atrophy (19, 9.2 %). Peripheral nerve disorders included carpal tunnel syndrome in 13 (6.3 %) and unilateral brachial plexus injury in 1 (1 %). Fifty-three (51.5 %) were diagnosed with facet joint syndrome at the level of the cervical spine (the most frequent site). Using a prosthesis was reported by 65 (63.1 %), both left and right sides. The back was the most common site of pain (71.8 %). The high prevalence of neuro-musculoskeletal disorders among bilateral upper extremity amputees indicates that they need regular rehabilitation care.

  20. Case Report: The casting motion to mobilize stiffness technique for rehabilitation after a crush and degloving injury of the hand.

    PubMed

    Midgley, Robyn

    2016-01-01

    Case report. This case report describes the use of the casting motion to mobilize stiffness (CMMS) technique in the management of a crush and degloving injury of the hand. The patient was unable to attend multiple hand therapy sessions due to geographic constraints. The CMMS technique involved the application of a nonremovable plaster of paris cast that selectively immobilizes proximal joints in an ideal position while constraining distal joints to direct desired motion over a long period. This uses active motion only. Traditional hand therapy techniques or modalities are not used. This treatment approach was beneficial to the patient as a minimum of 2 appointments per month were needed to regain functional hand use. To document the use of the CMMS technique as an effective treatment approach in the management of a crush and degloving injury of the hand. The CMMS technique was applied to the patient's left (nondominant) hand 8 weeks after injury. The technique's aim was to improve the 30° flexion deformity of the left wrist and flexion contractures of the index, middle, and ring fingers with a total active motion of 0°. Orthotic devices and traditional therapy were applied once joint stiffness was resolved, and a normal pattern of motion was reinstated. At 6 months, substantial improvement was noted in wrist as well as metacarpophalangeal and interphalangeal joints. Total active motion exceeded 170° in all fingers excellent functional outcome resulted as measured with the upper limb functional index short form-10. The upper limb functional index increased from 0% to 55% of preinjury status (or capacity) over the 18 months of therapy. Brief immobilization through casting causes certain functional losses, but these are temporary and reversible. Finger stiffness, edema, and tissue fibrosis were successfully managed with the CMMS technique without the need for attendance at multiple hand therapy sessions. Level V. Copyright © 2016 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  1. Generalised joint hypermobility and shoulder joint hypermobility, - risk of upper body musculoskeletal symptoms and reduced quality of life in the general population.

    PubMed

    Juul-Kristensen, Birgit; Østengaard, Lasse; Hansen, Sebrina; Boyle, Eleanor; Junge, Tina; Hestbaek, Lise

    2017-05-30

    Generalised Joint Hypermobility (GJH) is a hereditary condition with an ability to exceed the joints beyond the normal range. The prevalence of GJH in the adult population and its impact on upper body musculoskeletal health and quality of life has mostly been studied in selected populations. The aims of this study were therefore, firstly to study the prevalence of GJH and GJH including shoulder hypermobility (GJHS), in the general Danish adult population; secondly to test the associations between GJH or GJHS and upper body musculoskeletal symptoms and health-related quality of life (HRQoL). The study was cross-sectional where 2072 participants, aged 25-65, randomly extracted from the Danish Civil Registration System), were invited to answer a questionnaire battery (Five-Part Questionnaire for classification of GJH, Standardised Nordic Questionnaire for musculoskeletal symptoms, EuroQoL-5D for HRQoL). Totally 1006 (49%) participants responded. The prevalence of GJH and GJHS were 30% (n = 300) and 5% (n = 51), respectively. Compared with Non GJH (NGJH), participants with GJH and GJHS had Odds Ratio (OR) of 1.5-3.5 for upper body musculoskeletal symptoms within the last 12 months (mostly shoulders and hands/wrists). GJH and GJHS also had OR 1.6-4.4 for being prevented from usual activities, mostly due to shoulder and neck symptoms. Furthermore, GJH and GJHS had OR 2.2-3.1 for upper body musculoskeletal symptoms lasting for more than 90 days (neck, shoulders, hand/wrists), and 1.5-3.5 for reduced HRQoL (all dimensions, but anxiety/depression) compared with NGJH. Generally, most OR for GJHS were about twice as high as for those having GJH alone. GJH and GJHS are frequently self-reported musculoskeletal conditions in the Danish adult population. Compared with NGJH, GJH and especially GJHS, present with higher OR for upper body musculoskeletal symptoms, more severe symptoms and decreased HRQoL.

  2. Joint-specific risk of impaired function in fibrodysplasia ossificans progressiva (FOP).

    PubMed

    Pignolo, Robert J; Durbin-Johnson, Blythe P; Rocke, David M; Kaplan, Frederick S

    2018-04-01

    Fibrodysplasia ossificans progressiva (FOP) causes progressive disability due to heterotopic ossification from episodic flare-ups. Using data from 500 FOP patients (representing 63% of all known patients world-wide), age- and joint-specific risks of new joint involvement were estimated using parametric and nonparametric statistical methods. Compared to data from a 1994 survey of 44 individuals with FOP, our current estimates of age- and joint-specific risks of new joint involvement are more accurate (narrower confidence limits), based on a wider range of ages, and have less bias due to its greater comprehensiveness (captures over three-fifths of the known FOP patients worldwide). For the neck, chest, abdomen, and upper back, the estimated hazard decreases over time. For the jaw, lower back, shoulder, elbow, wrist, fingers, hip, knee, ankle, and foot, the estimated hazard increases initially then either plateaus or decreases. At any given time and for any anatomic site, the data indicate which joints are at risk. This study of approximately 63% of the world's known population of FOP patients provides a refined estimate of risk for new involvement at any joint at any age, as well as the proportion of patients with uninvolved joints at any age. Importantly, these joint-specific survival curves can be used to facilitate clinical trial design and to determine if potential treatments can modify the predicted trajectory of progressive joint dysfunction. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Demonstration of a geode by magnetic resonance imaging: a new light on the cause of juxta-articular bone cysts in rheumatoid arthritis.

    PubMed

    Moore, E A; Jacoby, R K; Ellis, R E; Fry, M E; Pittard, S; Vennart, W

    1990-10-01

    The magnetic resonance imaging (MRI) features of a rheumatoid arthritic geode are presented. Development of such a cyst from before x ray diagnosis to its coalescence with the wrist joint is described. The evidence suggests that these juxta-articular cysts are not merely an intrusion of the synovial cavity into the bone marrow but start as isolated structures beneath the subchondral bone.

  4. Demonstration of a geode by magnetic resonance imaging: a new light on the cause of juxta-articular bone cysts in rheumatoid arthritis.

    PubMed Central

    Moore, E A; Jacoby, R K; Ellis, R E; Fry, M E; Pittard, S; Vennart, W

    1990-01-01

    The magnetic resonance imaging (MRI) features of a rheumatoid arthritic geode are presented. Development of such a cyst from before x ray diagnosis to its coalescence with the wrist joint is described. The evidence suggests that these juxta-articular cysts are not merely an intrusion of the synovial cavity into the bone marrow but start as isolated structures beneath the subchondral bone. Images PMID:2241269

  5. Ipsilateral wrist-ankle movements in the sagittal plane encoded in extrinsic reference frame.

    PubMed

    Muraoka, Tetsuro; Ishida, Yuki; Obu, Takashi; Crawshaw, Larry; Kanosue, Kazuyuki

    2013-04-01

    When performing oscillatory movements of two joints in the sagittal plane, there is a directional constraint for performing such movements. Previous studies could not distinguish whether the directional constraint reflected movement direction encoded in the extrinsic (outside the body) reference frame or in the intrinsic (the participants' torso/head) reference frame since participants performed coordinated movements in a sitting position where the torso/head was stationary relative to the external world. In order to discern the reference frame in the present study, participants performed paced oscillatory movements of the ipsilateral wrist and ankle in the sagittal plane in a standing position so that the torso/head moved relative to the external world. The coordinated movements were performed in one of two modes of coordination, moving the hand upward concomitant with either ankle plantarflexion or ankle dorsiflexion. The same directional mode relative to extrinsic space was more stable and accurate as compared with the opposite directional mode. When forearm position was changed from the pronated position to the supinated position, similar results were obtained, indicating that the results were independent of a particular coupling of muscles. These findings suggest that the directional constraint on ipsilateral joints movements in the sagittal plane reflects movement direction encoded in the extrinsic reference frame. Copyright © 2013 Elsevier Ireland Ltd and the Japan Neuroscience Society. All rights reserved.

  6. Antero-medial approach to the wrist: anatomic basis and new application in cases of fracture of the lunate facet.

    PubMed

    Uzel, A-P; Bulla, A; Laurent-Joye, M; Caix, P

    2011-08-01

    The Henry approach is the classical anterolateral surgical exposure of the volar aspect of the distal radius. This approach does not allow good access to the medial side of the volar distal radius (lunate facet) and the distal radio-ulnar joint, unless it is extended proximally, retracting the tendons and the median nerve medially, which can cause some trauma. The purpose of our study was to investigate the anatomic basis and to outline the advantages of the unusual anteromedial approach, reporting our experience in the treatment of 4 distal radius fractures, with a 90° or 180° twist of the lunate facet, and 10 wrist dissections on cadavers. The average follow-up was 68.8 months (range 18 to 115 months). In our series, this approach did not cause any nerve injuries or any sensory loss of the distal forearm and the palm. All the fractures of the lunate facet and of the radial styloid process healed. One patient with an ulnar styloid process fracture associated showed pseudarthrosis, but with no instability of the distal radio-ulnar joint or pain on the ulnar side. Using the criteria of Green and O'Brien, modified by Cooney, the results were: excellent in two cases, good in one case, and average in another. The evaluation of arthritis according to Knirk and Jupiter's classification showed grade 0 in three cases and grade 3 in one case with osteochondral sclerosis. We showed that the anteromedial approach is reliable and convenient in the case of fractures situated in the antero-medial portion of the radius, for the double objective of reducing the fracture under direct control and checking the congruence of the distal radio-ulnar joint.

  7. Kinematic analysis of upper extremity movement during drinking in hemiplegic subjects.

    PubMed

    Kim, Kyung; Song, Won-Kyung; Lee, Jeongsu; Lee, Hwi-Young; Park, Dae Sung; Ko, Byung-Woo; Kim, Jongbae

    2014-03-01

    It is necessary to analyze the kinematic properties of a paralyzed extremity to quantitatively determine the degree of impairment of hemiplegic people during functional activities of daily living (ADL) such as a drinking task. This study aimed to identify the kinematic differences between 16 hemiplegic and 32 able-bodied participants in relation to the task phases when drinking with a cup and the kinematic strategy used during motion with respect to the gravity direction. The subjects performed a drinking task that was divided into five phases according to Murphy's phase definition: reaching, forward transport, drinking, backward transport, and returning. We found that the groups differed in terms of the movement times and the joint angles and angular velocities of the shoulder, elbow, and wrist joints. Compared to the control group, the hemiplegic participants had a larger shoulder abduction angle of at most 17.1° during all the phases, a larger shoulder flexion angle of 7.6° during the reaching phase, and a smaller shoulder flexion angle of 6.4° during the backward transporting phase. Because of these shoulder joint patterns, a smaller elbow pronation peak angle of at most 13.1° and a larger wrist extension peak angle of 12.0° were found in the motions of the hemiplegic participants, as compensation to complete the drinking task. The movement in the gravity direction during the backward transporting phase resulted in a 15.9% larger peak angular velocity for elbow extension in the hemiplegic participants compared to that of the control group. These quantitative kinematic patterns help provide an understanding of the movements of an affected extremity and can be useful in designing rehabilitation robots to assist hemiplegic people with ADL. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. [Dorsal capsular imbrication for dorsal instability of the distal radioulnar joint].

    PubMed

    Unglaub, F; Manz, S; Bruckner, T; Leclère, F M; Hahn, P; Wolf, M B

    2013-12-01

    To stabilize the distal radioulnar joint (DRUJ) by performing dorsal capsular imbrication in patients presenting with dorsal instability. The goal was to reduce pain and prevent the occurrence of posttraumatic arthrosis. Posttraumatic dorsal instability of the DRUJ with missing block while performing translational activities in the DRUJ or subluxation while actively rotating the forearm. Cases, in which other stabilizing techniques, such as, sutures of the triangular fibrocartilage complex failed. DRUJ arthrosis, previous surgical interventions to the capsule area of the DRUJ, instabilities due to osseous reasons (malposition or pseudarthrosis) should already have been treated. Dorsal approach and opening of the 5th extensor compartment to expose the dorsal joint capsule. A longitudinal division of the capsule was performed and sufficient tissue on the radial and ulnar border was retained to ensure a solid suture technique. Then 2 U-shaped sutures using FiberWire suture material were made. Correction of the malposition and repositioning the forearm into supination. Tightening of the prepared capsule sutures and closing of the retinaculum with a resorbable suture. Patients wore a long-arm cast with the forearm being in supination for a period of 4 weeks. Following cast removal, patients wore a forearm splint for a period of 4 weeks to limit forearm pronation/supination at 45°. Full load on the wrist was allowed after 12 weeks. The subjective and functional outcomes of 20 patients having received capsular imbrication using this technique were good and entailed no significant complications. The postoperative DASH was 15.8 points. Of the 20 patients, 17 patients (85%) had a reduction of pain. Symptoms of DRUJ instability could be reduced in 18 patients (90%). Pronation/supination of the wrist was not restricted postoperatively.

  9. Can baseline ultrasound results help to predict failure to achieve DAS28 remission after 1 year of tight control treatment in early RA patients?

    PubMed

    Ten Cate, D F; Jacobs, J W G; Swen, W A A; Hazes, J M W; de Jager, M H; Basoski, N M; Haagsma, C J; Luime, J J; Gerards, A H

    2018-01-30

    At present, there are no prognostic parameters unequivocally predicting treatment failure in early rheumatoid arthritis (RA) patients. We investigated whether baseline ultrasonography (US) findings of joints, when added to baseline clinical, laboratory, and radiographical data, could improve prediction of failure to achieve Disease Activity Score assessing 28 joints (DAS28) remission (<2.6) at 1 year in newly diagnosed RA patients. A multicentre cohort of newly diagnosed RA patients was followed prospectively for 1 year. US of the hands, wrists, and feet was performed at baseline. Clinical, laboratory, and radiographical parameters were recorded. Primary analysis was the prediction by logistic regression of the absence of DAS28 remission 12 months after diagnosis and start of therapy. Of 194 patients included, 174 were used for the analysis, with complete data available for 159. In a multivariate model with baseline DAS28 (odds ratio (OR) 1.6, 95% confidence interval (CI) 1.2-2.2), the presence of rheumatoid factor (OR 2.3, 95% CI 1.1-5.1), and type of monitoring strategy (OR 0.2, 95% CI 0.05-0.85), the addition of baseline US results for joints (OR 0.96, 95% CI 0.89-1.04) did not significantly improve the prediction of failure to achieve DAS28 remission (likelihood ratio test, 1.04; p = 0.31). In an early RA population, adding baseline ultrasonography of the hands, wrists, and feet to commonly available baseline characteristics did not improve prediction of failure to achieve DAS28 remission at 12 months. Clinicaltrials.gov, NCT01752309 . Registered on 19 December 2012.

  10. An immunohistochemical study of the triangular fibrocartilage complex of the wrist: regional variations in cartilage phenotype

    PubMed Central

    Milz, S; Sicking, B; Sprecher, C M; Putz, R; Benjamin, M

    2007-01-01

    The triangular fibrocartilage complex (TFCC) transmits load from the wrist to the ulna and stabilizes the distal radioulnar joint. Damage to it is a major cause of wrist pain. Although its basic structure is well established, little is known of its molecular composition. We have analysed the immunohistochemical labelling pattern of the extracellular matrix of the articular disc and the meniscal homologue of the TFCC in nine elderly individuals (age range 69–96 years), using a panel of monoclonal antibodies directed against collagens, glycosaminoglycans, proteoglycans and cartilage oligomeric matrix protein (COMP). Although many of the molecules (types I, III and VI collagen, chondroitin 4 sulphate, dermatan sulphate and keratan sulphate, the oversulphated epitope of chondroitin 6 sulphate, versican and COMP) were found in all parts of the TFCC, aggrecan, link protein and type II collagen were restricted to the articular disc and to entheses. They were thus not a feature of the meniscal homologue. The shift in tissue phenotype within the TFCC, from a fibrocartilaginous articular disc to a more fibrous meniscal homologue, correlates with biomechanical data suggesting that the radial region is stiff and subject to considerable stress concentration. The presence of aggrecan, link protein and type II collagen in the articular disc could explain why the TFCC is destroyed in rheumatoid arthritis, given that it has been suggested that autoimmunity to these antigens results in the destruction of articular cartilage. The differential distribution of aggrecan within the TFCC is likely to be reflected by regional differences in water content and mobility on the radial and ulnar side. This needs to be taken into account in the design of improved MRI protocols for visualizing this ulnocarpal complex of the wrist. PMID:17532798

  11. Treatment of Pisotriquetral Arthritis by Pyrocarbon Interposition Arthroplasty.

    PubMed

    Bellemère, Philippe; Aribert, Marion; Choughri, Hussein; Leroy, Marc; Gaisne, Etienne

    2018-02-01

    Purpose  Pisiformectomy is the baseline treatment for pisotriquetral arthritis when medical treatment fails to address the problem. This operation may lead to loss of mobility and strength in the wrist. This study reports the short-term outcomes of a new technique for treating pisotriquetral arthritis using a pisotriquetral interposition arthroplasty with a pyrocarbon implant. Patients and Methods  We performed a clinical and radiographic study on a series of eight patients who received this treatment at a mean follow-up of 2.8 years. We also studied the mobility of the implant and did assessed articular instability using dynamic radiology and fluoroscopy. Results  We observed one proximal dislocation of the implant in one hand which was reoperated to reposition the implant and strengthen the capsule. All patients were satisfied or very satisfied with their operation and had an average functional recovery period of 1.6 months. At the last follow-up, the Mayo Wrist Score (MWS), Quick Disability of Arm Shoulder and Hand (QDASH), and Patient-Rated Wrist Evaluation (PRWE) scores were 89, 18, and 20, respectively. Postoperatively, there was a 22% improvement in the grip strength of the wrists as well as improved mobility, mainly as regards the radioulnar deviation (47% improvement) and the Visual Analogue Scale (VAS) pain scores decreased from 8 preoperatively to 2 at the latest follow-up. The functional radiologic and fluoroscopic study reported good adaptive mobility of the implant in all the patients, without any indication of pisotriquetral joint instability. Conclusion  The short-term results of pisotriquetral arthroplasty using the Pyrocardan implant are encouraging. This new surgical solution appears to be a valid alternative to pisiformectomy or pisotriquetral arthrodesis. Long-term studies are required to confirm these preliminary findings.

  12. Development of an empirically based dynamic biomechanical strength model

    NASA Technical Reports Server (NTRS)

    Pandya, A.; Maida, J.; Aldridge, A.; Hasson, S.; Woolford, B.

    1992-01-01

    The focus here is on the development of a dynamic strength model for humans. Our model is based on empirical data. The shoulder, elbow, and wrist joints are characterized in terms of maximum isolated torque, position, and velocity in all rotational planes. This information is reduced by a least squares regression technique into a table of single variable second degree polynomial equations determining the torque as a function of position and velocity. The isolated joint torque equations are then used to compute forces resulting from a composite motion, which in this case is a ratchet wrench push and pull operation. What is presented here is a comparison of the computed or predicted results of the model with the actual measured values for the composite motion.

  13. Measurements of Generated Energy/Electrical Quantities from Locomotion Activities Using Piezoelectric Wearable Sensors for Body Motion Energy Harvesting

    PubMed Central

    Proto, Antonino; Penhaker, Marek; Bibbo, Daniele; Vala, David; Conforto, Silvia; Schmid, Maurizio

    2016-01-01

    In this paper, two different piezoelectric transducers—a ceramic piezoelectric, lead zirconate titanate (PZT), and a polymeric piezoelectric, polyvinylidene fluoride (PVDF)—were compared in terms of energy that could be harvested during locomotion activities. The transducers were placed into a tight suit in proximity of the main body joints. Initial testing was performed by placing the transducers on the neck, shoulder, elbow, wrist, hip, knee and ankle; then, five locomotion activities—walking, walking up and down stairs, jogging and running—were chosen for the tests. The values of the power output measured during the five activities were in the range 6 µW–74 µW using both transducers for each joint. PMID:27077867

  14. Laser acupuncture versus reflexology therapy in elderly with rheumatoid arthritis.

    PubMed

    Adly, Afnan Sedky; Adly, Aya Sedky; Adly, Mahmoud Sedky; Serry, Zahra M H

    2017-07-01

    The purposes of this study are to determine and compare efficacy of laser acupuncture versus reflexology in elderly with rheumatoid arthritis. Thirty elderly patients with rheumatoid arthritis aged between 60 and 70 years were classified into two groups, 15 patients each. Group A received laser acupuncture therapy (904 nm, beam area of 1cm 2 , power 100 mW, power density 100 mW/cm 2 , energy dosage 4 J, energy density 4 J/cm 2 , irradiation time 40 s, and frequency 100,000 Hz). The acupuncture points that were exposed to laser radiation are LR3, ST25, ST36, SI3, SI4, LI4, LI11, SP6, SP9, GB25, GB34, and HT7. While group B received reflexology therapy, both offered 12 sessions over 4 weeks. The changes in RAQoL, HAQ, IL-6, MDA, ATP, and ROM at wrist and ankle joints were measured at the beginning and end of treatment. There was significant decrease in RAQoL, HAQ, IL-6, and MDA pre/posttreatment for both groups (p < 0.05); significant increase in ATP pre/posttreatment for both groups (p < 0.05); significant increase in ankle dorsi-flexion, plantar-flexion, wrist flexion, extension, and ulnar deviation ROM pre/posttreatment in group A (p < 0.05); and significant increase in ankle dorsi-flexion and ankle plantar-flexion ROM pre/posttreatment in group B (p < 0.05). Comparison between both groups showed a statistical significant decrease in MDA and a statistical significant increase in ATP in group A than group B. Percent of changes in MDA was 41.82%↓ in group A versus 21.68%↓ in group B; changes in ATP was 226.97%↑ in group A versus 67.02%↑ in group B. Moreover, there was a statistical significant increase in ankle dorsi-flexion, ankle plantar-flexion, wrist flexion, wrist extension, and radial deviation in group A than group B. Laser therapy is associated with significant improvement in MDA and ATP greater than reflexology. In addition, it is associated with significant improvement in ankle dorsi-flexion, ankle plantar-flexion, wrist flexion, wrist extension, and radial deviation greater than reflexology in elderly patients with rheumatoid arthritis.

  15. Grade and location of power Doppler are predictive of damage progression in rheumatoid arthritis patients in clinical remission by anti-tumour necrosis factor α.

    PubMed

    Raffeiner, Bernd; Grisan, Enrico; Botsios, Costantino; Stramare, Roberto; Rizzo, Gaia; Bernardi, Livio; Punzi, Leonardo; Ometto, Francesca; Doria, Andrea

    2017-08-01

    To investigate power Doppler (PD) signal, grade and location and their association with radiographic progression in RA patients in remission. A prospective observational study was conducted in 125 consecutive RA patients in stable 28-joint DAS (DAS28) remission (⩾6 months) achieved on anti-TNF-α. At baseline, patients in stable remission underwent radiographic and US examination of the wrists and MCP, PIP and MTP joints. Semi-quantitative PD scoring (0-3) was recorded. We scored PD according to two locations: capsular or within synovial tissue without bone contact (location 1) and with bone contact or penetrating bone cortex (location 2). Radiographic progression was evaluated at the 1 year follow-up and defined as a change in van der Heijde-modified total Sharp score >0. Risk ratios (RRs) of radiographic progression according to presence, grade and location of PD were calculated. Four patients were excluded because of missing data. At baseline, 59/121 (48.7%) patients had a PD signal in one or more joints. PD location 2 was found in 74.6% patients (44/59). At the 1 year follow-up, 17/121 patients experienced radiographic progression: all had PD signal in one or more joints at baseline (RR 2.47, P < 0.0001). Radiographic progression was associated with the following baseline US features: PD grade 2 (RR 4.58, P < 0.01), PD grade 3 (RR 3.49, P < 0.05), total PD score ⩾2 (sum of all PD scores) (RR 3.19, P < 0.0001) and PD location 2 (RR 3.49, P < 0.0001). Higher PD grades and PD in contact with/or penetrating bone are associated with radiographic progression in patients in DAS28 remission. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  16. The Movement- and Load-Dependent Differences in the EMG Patterns of the Human Arm Muscles during Two-Joint Movements (A Preliminary Study)

    PubMed Central

    Tomiak, Tomasz; Abramovych, Tetiana I.; Gorkovenko, Andriy V.; Vereshchaka, Inna V.; Mishchenko, Viktor S.; Dornowski, Marcin; Kostyukov, Alexander I.

    2016-01-01

    Slow circular movements of the hand with a fixed wrist joint that were produced in a horizontal plane under visual guidance during conditions of action of the elastic load directed tangentially to the movement trajectory were studied. The positional dependencies of the averaged surface EMGs in the muscles of the elbow and shoulder joints were compared for four possible combinations in the directions of load and movements. The EMG intensities were largely correlated with the waves of the force moment computed for a corresponding joint in the framework of a simple geometrical model of the system: arm - experimental setup. At the same time, in some cases the averaged EMGs exit from the segments of the trajectory restricted by the force moment singular points (FMSPs), in which the moments exhibited altered signs. The EMG activities display clear differences for the eccentric and concentric zones of contraction that are separated by the joint angle singular points (JASPs), which present extreme at the joint angle traces. We assumed that the modeled patterns of FMSPs and JASPs may be applied for an analysis of the synergic interaction between the motor commands arriving at different muscles in arbitrary two-joint movements. PMID:27375496

  17. Functional Ability Improved in Essential Tremor by IncobotulinumtoxinA Injections Using Kinematically Determined Biomechanical Patterns – A New Future

    PubMed Central

    Samotus, Olivia; Rahimi, Fariborz; Lee, Jack; Jog, Mandar

    2016-01-01

    Objective Effective treatment for functional disability caused by essential tremor is a significant unmet need faced by many clinicians today. Current literature regarding focal therapy by botulinum toxin type A (BoNT-A) injections uses fixed dosing regimens, which cannot be individualized, provides only limited functional benefit and unacceptable muscle weakness commonly occurs. This 38-week open label study, the longest to-date, demonstrates how kinematic technology addressed all these issues by guiding muscle selection. Method Participants (n = 24) were assessed at weeks 0, 6, 16, 22, 32, and 38 and injected with incobotulinumtoxinA at weeks 0, 16, and 32. Clinical assessments including UPDRS tremor items, Fahn-Tolosa-Marin (FTM) tremor rating scale assessing tremor severity, writing and functional ability, quality of life questionnaire (QUEST) and objective kinematic assessments were completed at every visit. Participants performed two postural and two weight-bearing scripted tasks with motion sensors placed over the wrist, elbow and shoulder joints. These sensors captured angular tremor amplitude (RMS units) and acceleration joint motion that was segmented into directional components: flexion-extension (F/E), pronation-supination and radial-ulnar at the wrist, F/E at the elbow, and F/E and adduction-abduction at the shoulder. Injection parameters were determined using kinematics, followed by the clinician’s determination of which muscles would contribute to the specific upper limb tremor biomechanics and dosing per participant. Results Multi-joint biomechanical recordings allowed individualized muscle selection and showed significant improvement in whole-arm function, FTM parts A-C scores, at week 6 which continued throughout the study. By week 38, the total FTM score statistically significantly reduced from 16.2±4.6 at week 0 to 9.5±6.3 (p<0.0005). UPDRS item 21 score rating action tremor was significantly reduced from 2.6±0.5 at week 0 to 1.6±1.1 (p = 0.01) at week 32. Quality of life (QUEST) significantly improved from 40.3±15.8 at week 0 to 31.1±15.3 (p = 0.035) at week 32 and to 27.8±15.3 (p = 0.028) at week 38. Kinematics provided an objective, secondary outcome measure, which showed a significant decrease in tremor amplitude in the wrist and shoulder joints (p<0.05). Eight participants (40%) self-reported mild weakness in injected muscles but had no interference in arm function. Conclusion Kinematic tremor assessments provide the injector unique insight to objectively individualize and personalize injection parameters demonstrating BoNT-A effectively alleviates functional disability caused by essential tremor. Kinematic technology is a promising method for standardizing assessments and for focal upper limb tremor treatment. Trial Registration ClinicalTrials.gov NCT02427646 PMID:27101283

  18. Ergonomics and musculoskeletal pain among postgraduate students and faculty members of the School of Dentistry of the University of Barcelona (Spain). A cross-sectional study.

    PubMed

    Harutunian, Karmen; Gargallo-Albiol, Jordi; Figueiredo, Rui; Gay-Escoda, Cosme

    2011-05-01

    To evaluate the intensity and location of musculoskeletal pain suffered by students and professors from different postgraduate programs of the School of Dentistry of the University of Barcelona (Spain), to identify the variables related to the occurrence of musculoskeletal symptoms and signs, and to establish possible preventive measures for such disorders. A cross-sectional study was made among students and faculty members from different postgraduate courses of the School of Dentistry at the University of Barcelona between May and June 2007. A total of 74 dentists (54 postgraduate students and 20 faculty members) completed an anonymous questionnaire containing 19 questions. The variables were divided into three main groups: sociodemographic information, ergonomic features and musculoskeletal pain arising from professional practice. Most of the dentists (79.8%) had experienced some kind of musculoskeletal pain in the last 6 months. On comparing the different locations of pain (lumbar, cervical, dorsal, wrist, shoulder and others), the neck was found to be the most commonly affected location (58% of all subjects), and only 34% of the respondents took some preventive measures against musculoskeletal disorders. Women showed a higher frequency of intense pain involving the cervical, lumbar, dorsal and wrist areas (p<0.05). A higher incidence of wrist pain was recorded in professionals exclusively dedicated to oral surgery (p<0.05). No statistically significant correlation was found between the workload (hours) and pain in the different anatomical locations (p>0.05). An important incidence of pain symptoms secondary to musculoskeletal disorders was observed, particularly in the cervical region. Females and younger dentists showed a higher frequency of such symptoms. The implementation of preventive measures is necessary, in view of the high incidence of these disorders.

  19. Autofeedback from ultrasound images provides rapid improvement in palpation skills for identifying joint swelling in rheumatoid arthritis.

    PubMed

    Ogasawara, Michihiro; Murayama, Go; Yamada, Yusuke; Nemoto, Takuya; Kageyama, Michiaki; Toyama, Shoko; Kusaoi, Makio; Onuma, Shin; Kon, Takayuki; Sekiya, Fumio; Sugimoto, Kaoru; Matsudaira, Ran; Matsushita, Masakazu; Tada, Kurisu; Kempe, Kazuo; Yamaji, Ken; Tamura, Naoto; Takasaki, Yoshinari

    2012-06-01

    Joint swelling, an important factor in the classification criteria and disease activity assessment in rheumatoid arthritis (RA), renders joint palpation a necessary skill for physicians. Ultrasound (US) examination that visualizes soft tissue abnormalities is now used to assess musculoskeletal disease. We assessed the usefulness of US assessments in enhancing physical joint examination skills. We examined 1944 joints (bilateral shoulder, elbow, wrist, metacarpophalangeal joints 1-5, and knee joints) in 108 patients with RA during April-July 2011. We first physically examined and confirmed joint swelling; subsequently, the same rheumatologist conducted US examinations and multiple assessors graded the joint swelling. When the 2 results differed, we received autofeedback from the US results to improve the physical examination skills. The sensitivities and specificities of physical examination for US-detected swollen joint, the correlation coefficient (CC) of the swollen joint counts, and the concordance rate in each patient for joint swelling sites and power Doppler (PD)-positive sites with the κ coefficients between the physical and US examinations were compared over time. We found that the sensitivity of physical examination increased by 42 percentage points (pp), while the specificity decreased by 18 pp. The average CC in June-July was greater than that in April-May. The percentage of κ coefficients > 0.8 increased from 8.8% to 17% for joint swelling and from 8.3% to 14% for PD-positive sites. Our results suggest that autofeedback from US assessment provides quick improvement in palpation skills for identifying joint swelling in patients with RA.

  20. Effectiveness of Occupational Therapy Interventions for Adults With Musculoskeletal Conditions of the Forearm, Wrist, and Hand: A Systematic Review

    PubMed Central

    Hardison, Mark E.

    2017-01-01

    Occupational therapy practitioners are key health care providers for people with musculoskeletal disorders of the distal upper extremity. It is imperative that practitioners understand the most effective and efficient means for remediating impairments and supporting clients in progressing to independence in purposeful occupations. This systematic review provides an update to a previous review by summarizing articles published between 2006 and July 2014 related to the focused question, What is the evidence for the effect of occupational therapy interventions on functional outcomes for adults with musculoskeletal disorders of the forearm, wrist, and hand? A total of 59 articles were reviewed. Evidence for interventions was synthesized by condition within bone, joint, and general hand disorders; peripheral nerve disorders; and tendon disorders. The strongest evidence supports postsurgical early active motion protocols and splinting for various conditions. Very few studies have examined occupation-based interventions. Implications for occupational therapy practice and research are provided. PMID:28027038

  1. Effectiveness of Occupational Therapy Interventions for Adults With Musculoskeletal Conditions of the Forearm, Wrist, and Hand: A Systematic Review.

    PubMed

    Roll, Shawn C; Hardison, Mark E

    Occupational therapy practitioners are key health care providers for people with musculoskeletal disorders of the distal upper extremity. It is imperative that practitioners understand the most effective and efficient means for remediating impairments and supporting clients in progressing to independence in purposeful occupations. This systematic review provides an update to a previous review by summarizing articles published between 2006 and July 2014 related to the focused question, What is the evidence for the effect of occupational therapy interventions on functional outcomes for adults with musculoskeletal disorders of the forearm, wrist, and hand? A total of 59 articles were reviewed. Evidence for interventions was synthesized by condition within bone, joint, and general hand disorders; peripheral nerve disorders; and tendon disorders. The strongest evidence supports postsurgical early active motion protocols and splinting for various conditions. Very few studies have examined occupation-based interventions. Implications for occupational therapy practice and research are provided. Copyright © 2017 by the American Occupational Therapy Association, Inc.

  2. Risk of Osteoporotic Fracture After Steroid Injections in Patients With Medicare.

    PubMed

    Carreon, Leah Y; Ong, Kevin L; Lau, Edmund; Kurtz, Steven M; Glassman, Steven D

    To further evaluate the relationship between steroid injections and osteoporotic fracture risk, we analyzed Medicare administrative claims data on both large-joint steroid injections (LJSIs) into knee and hip and transforaminal steroid injections (TSIs), as well as osteoporotic hip and wrist fractures. Our hypothesis was that a systemic effect of steroid injections would increase fracture risk in all skeletal locations regardless of injection site, whereas a local effect would produce a disproportionate increased risk of spine fracture with spine injection. Patients treated with an LJSI, a TSI, or an epidural steroid injection (ESI) were identified from 5% Medicare claims data. Patients under age 65 years and patients with prior osteoporotic fracture were excluded. Analyses were performed to determine fracture risk (adjusted hazard ratio) for each type of injection. Analysis of the Medicare data revealed that ESIs were associated with decreased osteoporotic spine fracture risk, but the effect was small and might not be clinically relevant. ESIs did not influence osteoporotic hip or wrist fracture risk, but LJSIs reduced the risk.

  3. Upper limb congenital muscular hypertrophy and aberrant muscle syndrome in children.

    PubMed

    Dahan, Emmanuel; Chaves, Camilo; Bachy, Manon; Fitoussi, Frank

    2018-01-01

    Congenital muscle hypertrophy of the upper limb is a very rare condition with unknown aetiology. This descriptive observational and retrospective series included eight children followed by a multidisciplinary team from 2005 to 2017. The diagnosis was based on a cluster of clinical and radiological characteristics after elimination of differential diagnoses. Patients were categorized according to: anomalies of the wrist, anomalies of long fingers of intrinsic or extrinsic origin; and anomalies of the thumb with or without first web space contracture. Treatment begins in young children with hand orthoses to limit muscle contraction and joint malposition. The purpose of surgical treatment was to release contractures and to restore muscle balance through, in the main, finger intrinsic releases and first web releases. At the 2-year follow-up, we found that limited surgical procedures improved finger, thumb and wrist positions. We conclude that muscle hypertrophy is the main cause of deformity and that selective releases of contracted musculo-tendinous units and skin lengthening are effective. IV.

  4. Sample Acquisition and Instrument Deployment (SAID)

    NASA Technical Reports Server (NTRS)

    Boyd, Robert C.

    1994-01-01

    This report details the interim progress for contract NASW-4818, Sample Acquisition and Instrument Deployment (SAID), a robotic system for deploying science instruments and acquiring samples for analysis. The system is a conventional four degree of freedom manipulator 2 meters in length. A baseline design has been achieved through analysis and trade studies. The design considers environmental operating conditions on the surface of Mars, as well as volume constraints on proposed Mars landers. Control issues have also been studied, and simulations of joint and tip movements have been performed. A passively braked shape memory actuator with the ability to measure load has been developed. The wrist also contains a mechanism which locks the lid output to the bucket so that objects can be grasped and released for instrument deployment. The wrist actuator has been tested for operational power and mechanical functionality at Mars environmental conditions. The torque which the actuator can produce has been measured. Also, testing in Mars analogous soils has been performed.

  5. Bilateral force reflection for teleoperators with masters and slaves with dissimilar and possibly redundant kinematics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jansen, J.F.; Babcock, S.M.

    1989-11-01

    Several bilateral control techniques and methods for exploiting redundant slaves are investigated as a part of research to develop and analyze bilateral, force-reflecting control methodologies for teleoperator systems with kinematic dissimilar masters and slaves. The study indicates that, with force/torque sensing at the wrist, and an impedance type of controller with the appropriate joint compensation, a significant improvement in performance and controllability of a teleoperator system can be achieved. 32 refs., 6 figs., 2 tabs.

  6. Recurrence plots and recurrence quantification analysis of human motion data

    NASA Astrophysics Data System (ADS)

    Josiński, Henryk; Michalczuk, Agnieszka; Świtoński, Adam; Szczesna, Agnieszka; Wojciechowski, Konrad

    2016-06-01

    The authors present exemplary application of recurrence plots, cross recurrence plots and recurrence quantification analysis for the purpose of exploration of experimental time series describing selected aspects of human motion. Time series were extracted from treadmill gait sequences which were recorded in the Human Motion Laboratory (HML) of the Polish-Japanese Academy of Information Technology in Bytom, Poland by means of the Vicon system. Analysis was focused on the time series representing movements of hip, knee, ankle and wrist joints in the sagittal plane.

  7. Musculoskeletal disease burden of hereditary hemochromatosis.

    PubMed

    Sahinbegovic, Enijad; Dallos, Tomáš; Aigner, Elmar; Axmann, Roland; Manger, Bernhard; Englbrecht, Matthias; Schöniger-Hekele, Maximilian; Karonitsch, Thomas; Stamm, Tanja; Farkas, Martin; Karger, Thomas; Stölzel, Ulrich; Keysser, Gernot; Datz, Christian; Schett, Georg; Zwerina, Jochen

    2010-12-01

    To determine the prevalence, clinical picture, and disease burden of arthritis in patients with hereditary hemochromatosis. In this cross-sectional observational study of 199 patients with hemochromatosis and iron overload, demographic and disease-specific variables, genotype, and organ involvement were recorded. The prevalence, intensity, and localization of joint pain were assessed, and a complete rheumatologic investigation was performed. Radiographs of the hands, knees, and ankles were scored for joint space narrowing, erosions, osteophytes, and chondrocalcinosis. In addition, the number and type of joint replacement surgeries were recorded. Joint pain was reported by 72.4% of the patients. Their mean ± SD age at the time of the initial joint symptoms was 45.8 ± 13.2 years. If joint pain was present, it preceded the diagnosis of hemochromatosis by a mean ± SD of 9.0 ± 10.7 years. Bony enlargement was observed in 65.8% of the patients, whereas synovitis was less common (13.6%). Joint space narrowing and osteophytes as well as chondrocalcinosis of the wrist and knee joints were frequent radiographic features of hemochromatosis. Joint replacement surgery was common, with 32 patients (16.1%) undergoing total joint replacement surgery due to severe OA. The mean ± SD age of these patients was 58.3 ± 10.4 years at time of joint replacement surgery. Female sex, metacarpophalangeal joint involvement, and the presence of chondrocalcinosis were associated with a higher risk of early joint failure (i.e., the need for joint replacement surgery). Arthritis is a frequent, early, and severe symptom of hemochromatosis. Disease is not confined to involvement of the metacarpophalangeal joints and often leads to severe damage requiring the replacement of joints. Copyright © 2010 by the American College of Rheumatology.

  8. The correlation between proprioception and handwriting legibility in children

    PubMed Central

    Hong, So Young; Jung, Nam-Hae; Kim, Kyeong Mi

    2016-01-01

    [Purpose] This study investigated the association between proprioception, including joint position sense and kinetic sense, and handwriting legibility in healthy children. [Subjects and Methods] Assessment of joint position sense, kinetic sense, and handwriting legibility was conducted for 19 healthy children. Joint position sense was assessed by asking the children to flex their right elbow between 30° to 110° while blindfolded. The range of elbow movement was analyzed with Compact Measuring System 10 for 3D motion Analysis. Kinetic sense was assessed using the Sensory Integration and Praxis Test. The children were directed to write 30 words from the Korean alphabet, and the legibility of their handwriting was scored for form, alignment, space, size, and shape. To analyze the data, descriptive statistics and Spearman correlation analysis were conducted using IBM SPSS Statistics 20.0. [Results] There was significant negative correlation between handwriting legibility and Kinetic sense. A significant correlation between handwriting legibility and Joint position sense was not found. [Conclusion] This study showed that a higher Kinetic sense was associated with better legibility of handwriting. Further work is needed to determine the association of handwriting legibility and speed with Joint position sense of the elbow, wrist, and fingers. PMID:27821948

  9. Effects of inactivation of the anterior interpositus nucleus on the kinematic and dynamic control of multijoint movement.

    PubMed

    Cooper, S E; Martin, J H; Ghez, C

    2000-10-01

    We previously showed that inactivating the anterior interpositus nucleus in cats disrupts prehension; paw paths, normally straight and accurate, become curved, hypometric, and more variable. In the present study, we determined the joint kinematic and dynamic origins of this impairment. Animals were restrained in a hammock and trained to reach and grasp a cube of meat from a narrow food well at varied heights; movements were monitored using the MacReflex analysis system. The anterior interpositus nucleus was inactivated by microinjection of the GABA agonist muscimol (0.25-0.5 microgram in 0.5 microliter saline). For each joint, we computed the torque due to gravity, inertial resistance (termed self torque), interjoint interactions (termed interaction torque), and the combined effects of active muscle contraction and passive soft tissue stretch (termed generalized muscle torque). Inactivation produced significant reductions in the amplitude, velocity, and acceleration of elbow flexion. However, these movements continued to scale normally with target height. Shoulder extension was reduced by inactivation but wrist angular displacement and velocity were not. Inactivation also produced changes in the temporal coordination between elbow, shoulder, and wrist kinematics. Dynamic analysis showed that elbow flexion both before and during inactivation was produced by the combined action of muscle and interaction torque, but that the timing depended on muscle torque. Elbow interaction and muscle torques were scaled to target height both before and during inactivation. Inactivation produced significant reductions in elbow flexor interaction and muscle torques. The duration of elbow flexor muscle torque was prolonged to compensate for the reduction in flexor interaction torque. Shoulder extension was produced by extensor interaction and muscle torques both before and during inactivation. Inactivation produced a reduction in shoulder extension, primarily by reduced interaction torque, but without compensation. Wrist plantarflexion, which occurred during elbow flexion, was driven by plantarflexor interaction and gravitational torques both before and during inactivation. Muscle torque acted in the opposite direction with a phase lead to restrain the plantarflexor interaction torque. During inactivation, there was a reduction in plantarflexor interaction torque and a loss of the phase lead of the muscle torque. Our findings implicate the C1/C3 anterior interpositus zone of the cerebellum in the anticipatory control of intersegmental dynamics during reaching, which zone is required for coordinating the motions of the shoulder and wrist with those of the elbow. In contrast, this cerebellar zone does not play a role in scaling the movement to match a target.

  10. Kinematics, controls, and path planning results for a redundant manipulator

    NASA Technical Reports Server (NTRS)

    Gretz, Bruce; Tilley, Scott W.

    1989-01-01

    The inverse kinematics solution, a modal position control algorithm, and path planning results for a 7 degree of freedom manipulator are presented. The redundant arm consists of two links with shoulder and elbow joints and a spherical wrist. The inverse kinematics problem for tip position is solved and the redundant joint is identified. It is also shown that a locus of tip positions exists in which there are kinematic limitations on self-motion. A computationally simple modal position control algorithm has been developed which guarantees a nearly constant closed-loop dynamic response throughout the workspace. If all closed-loop poles are assigned to the same location, the algorithm can be implemented with very little computation. To further reduce the required computation, the modal gains are updated only at discrete time intervals. Criteria are developed for the frequency of these updates. For commanding manipulator movements, a 5th-order spline which minimizes jerk provides a smooth tip-space path. Schemes for deriving a corresponding joint-space trajectory are discussed. Modifying the trajectory to avoid joint torque saturation when a tip payload is added is also considered. Simulation results are presented.

  11. The biomechanics of upper extremity kinematic and kinetic modeling: applications to rehabilitation engineering.

    PubMed

    Slavens, Brooke A; Harris, Gerald F

    2008-01-01

    Human motion analysis has evolved from the lower extremity to the upper extremity. Rehabilitation engineering is reliant upon three-dimensional biome-chanical models for a thorough understanding of upper body motions and forces in order to improve treatment methods, rehabilitation strategies and to prevent injury. Due to the complex nature of upper body movements, a standard biomechanical model does not exist. This paper reviews several kinematic and kinetic rehabilitation engineering models from the literature. These models may capture a single joint; multijoints such as the shoulder, elbow and wrist; or a combination of joints and an ambulatory aid, which serves as the extension of the upper arm. With advances in software and hardware, new models continuously arise due to the clinical questions at hand. When designing a biomechanical upper extremity model, several key components must be determined. These include deciding on the anatomic segments of the model, the number of markers and placement on bony landmarks, the definition of joint coordinate systems, and the description of the joint motions. It is critical to apply the proper model to further our understanding of pathologic populations.

  12. Temporal Control and Hand Movement Efficiency in Skilled Music Performance

    PubMed Central

    Goebl, Werner; Palmer, Caroline

    2013-01-01

    Skilled piano performance requires considerable movement control to accomplish the high levels of timing and force precision common among professional musicians, who acquire piano technique over decades of practice. Finger movement efficiency in particular is an important factor when pianists perform at very fast tempi. We document the finger movement kinematics of highly skilled pianists as they performed a five-finger melody at very fast tempi. A three-dimensional motion-capture system tracked the movements of finger joints, the hand, and the forearm of twelve pianists who performed on a digital piano at successively faster tempi (7–16 tones/s) until they decided to stop. Joint angle trajectories computed for all adjacent finger phalanges, the hand, and the forearm (wrist angle) indicated that the metacarpophalangeal joint contributed most to the vertical fingertip motion while the proximal and distal interphalangeal joints moved slightly opposite to the movement goal (finger extension). An efficiency measure of the combined finger joint angles corresponded to the temporal accuracy and precision of the pianists’ performances: Pianists with more efficient keystroke movements showed higher precision in timing and force measures. Keystroke efficiency and individual joint contributions remained stable across tempo conditions. Individual differences among pianists supported the view that keystroke efficiency is required for successful fast performance. PMID:23300946

  13. Characterization of 3D joint space morphology using an electrostatic model (with application to osteoarthritis)

    NASA Astrophysics Data System (ADS)

    Cao, Qian; Thawait, Gaurav; Gang, Grace J.; Zbijewski, Wojciech; Reigel, Thomas; Brown, Tyler; Corner, Brian; Demehri, Shadpour; Siewerdsen, Jeffrey H.

    2015-02-01

    Joint space morphology can be indicative of the risk, presence, progression, and/or treatment response of disease or trauma. We describe a novel methodology of characterizing joint space morphology in high-resolution 3D images (e.g. cone-beam CT (CBCT)) using a model based on elementary electrostatics that overcomes a variety of basic limitations of existing 2D and 3D methods. The method models each surface of a joint as a conductor at fixed electrostatic potential and characterizes the intra-articular space in terms of the electric field lines resulting from the solution of Gauss’ Law and the Laplace equation. As a test case, the method was applied to discrimination of healthy and osteoarthritic subjects (N = 39) in 3D images of the knee acquired on an extremity CBCT system. The method demonstrated improved diagnostic performance (area under the receiver operating characteristic curve, AUC > 0.98) compared to simpler methods of quantitative measurement and qualitative image-based assessment by three expert musculoskeletal radiologists (AUC = 0.87, p-value = 0.007). The method is applicable to simple (e.g. the knee or elbow) or multi-axial joints (e.g. the wrist or ankle) and may provide a useful means of quantitatively assessing a variety of joint pathologies.

  14. From reaching to reach-to-grasp: the arm posture difference and its implications on human motion control strategy.

    PubMed

    Li, Zhi; Milutinović, Dejan; Rosen, Jacob

    2017-05-01

    Reach-to-grasp arm postures differ from those in pure reaching because they are affected by grasp position/orientation, rather than simple transport to a position during a reaching motion. This paper investigates this difference via an analysis of experimental  data collected on reaching and reach-to-grasp motions. A seven-degree-of-freedom (DOFs) kinematic arm model with the swivel angle is used for the motion analysis. Compared to a widely used anatomical arm model, this model distinguishes clearly the four grasping-relevant DOFs (GR-DOFs) that are affected by positions and orientations of the objects to be grasped. These four GR-DOFs include the swivel angle that measures the elbow rotation about the shoulder-wrist axis, and three wrist joint angles. For each GR-DOF, we quantify position vs orientation task-relevance bias that measures how much the DOF is affected by the grasping position vs orientation. The swivel angle and forearm supination have similar bias, and the analysis of their motion suggests two hypotheses regarding the synergistic coordination of the macro- and micro-structures of the human arm (1) DOFs with similar task-relevance are synergistically coordinated; and (2) such synergy breaks when a task-relevant DOF is close to its joint limit without necessarily reaching the limit. This study provides a motion analysis method to reduce the control complexity for reach-to-grasp tasks, and suggests using dynamic coupling to coordinate the hand and arm of upper-limb exoskeletons.

  15. Biomechanical effects of mobile computer location in a vehicle cab.

    PubMed

    Saginus, Kyle A; Marklin, Richard W; Seeley, Patricia; Simoneau, Guy G; Freier, Stephen

    2011-10-01

    The objective of this research is to determine the best location to place a conventional mobile computer supported by a commercially available mount in a light truck cab. U.S. and Canadian electric utility companies are in the process of integrating mobile computers into their fleet vehicle cabs. There are no publications on the effect of mobile computer location in a vehicle cab on biomechanical loading, performance, and subjective assessment. The authors tested four locations of mobile computers in a light truck cab in a laboratory study to determine how location affected muscle activity of the lower back and shoulders; joint angles of the shoulders, elbows, and wrist; user performance; and subjective assessment. A total of 22 participants were tested in this study. Placing the mobile computer closer to the steering wheel reduced low back and shoulder muscle activity. Joint angles of the shoulders, elbows, and wrists were also closer to neutral angle. Biomechanical modeling revealed substantially less spinal compression and trunk muscle force. In general, there were no practical differences in performance between the locations. Subjective assessment indicated that users preferred the mobile computer to be as close as possible to the steering wheel. Locating the mobile computer close to the steering wheel reduces risk of injuries, such as low back pain and shoulder tendonitis. Results from the study can guide electric utility companies in the installation of mobile computers into vehicle cabs. Results may also be generalized to other industries that use trucklike vehicles, such as construction.

  16. Wrist torque estimation during simultaneous and continuously changing movements: surface vs. untargeted intramuscular EMG.

    PubMed

    Kamavuako, Ernest N; Scheme, Erik J; Englehart, Kevin B

    2013-06-01

    In this paper, the predictive capability of surface and untargeted intramuscular electromyography (EMG) was compared with respect to wrist-joint torque to quantify which type of measurement better represents joint torque during multiple degrees-of-freedom (DoF) movements for possible application in prosthetic control. Ten able-bodied subjects participated in the study. Surface and intramuscular EMG was recorded concurrently from the right forearm. The subjects were instructed to track continuous contraction profiles using single and combined DoF in two trials. The association between torque and EMG was assessed using an artificial neural network. Results showed a significant difference between the two types of EMG (P < 0.007) for all performance metrics: coefficient of determination (R(2)), Pearson correlation coefficient (PCC), and root mean square error (RMSE). The performance of surface EMG (R(2) = 0.93 ± 0.03; PCC = 0.98 ± 0.01; RMSE = 8.7 ± 2.1%) was found to be superior compared with intramuscular EMG (R(2) = 0.80 ± 0.07; PCC = 0.93 ± 0.03; RMSE = 14.5 ± 2.9%). The higher values of PCC compared with R(2) indicate that both methods are able to track the torque profile well but have some trouble (particularly intramuscular EMG) in estimating the exact amplitude. The possible cause for the difference, thus the low performance of intramuscular EMG, may be attributed to the very high selectivity of the recordings used in this study.

  17. [Clinical Efficacy of Supplementary Treatment of Gukang Capsules to the Elder Patients with Fracture of Distal Radius].

    PubMed

    Wang, Wei; Liao, Su-ping; Wei, Lei

    2015-01-01

    To study the clinical efficacy of supplementary treatment of tukang Capsules to the elder patients with fracture of the distal radius. A total of 108 elder patients with fracture of the distal radius diagnosed by X-ray,who visited orthopedics department of Pu' ai Hospital in January 2012 - December 2013, were randomly divided into observation group and control group. Cases in both groups received the operation of internal fixation by T-type plate. Cases in control group received oral Calcium Carbonate Tablets, and cases in observation group received Gukang Capsules besides Calcium Carbonate Tablets. Treatment duration was four weeks. The painful and swelling degree of wrist joints, levels of type I propeptide carboxy-terminal procollagen (P I CP) and bone glaprotein(BGP) in serum were compared. Hospitalization and fracture healing time, as well as recovery condition of wrist joints in the sixth month after operation were compared. The VAS of both groups was not significantly different before operation and in the 28th day after operation(P >0. 05), but the VAS in observation group was significantly lower than that in control group in the 3rd,5th, 7th, 14th and 21th day after operation(P <0. 01). The swelling scale of both groups was not significantly different before operation and in the 28th day after operation(P >0. 05), but the swelling scale in observation group was significantly lower than that in control group in the 3rd, 5th, 7th, 14th and 21th day after operation(P <0. 01). The levels of P I CP and BGP in serum of both groups were not significantly different before operation(P >0. 05), but the levels of P I CP and BGP in serum of observation groups were significantly higher than that in control group one and two months after operation (P <0. 01). Hospitalization and fracture healing time in observation group was significantly shortened compared with control group (P <0. 05). The effective ratio in observation group was 79. 63%, significantly higher than that in control group (P <0. 05). Gukang Capsules supplementary to internal fixation by T-type plate has favorable efficacy to fracture of the distal radius, which can reduce pain and swelling, increase levels of P I CP and BGP in serum, as well as promote the heal of fracture and recovery of wrist joints function.

  18. A biomechanical analysis of upper extremity kinetics in children with cerebral palsy using anterior and posterior walkers.

    PubMed

    Konop, Katherine A; Strifling, Kelly M B; Wang, Mei; Cao, Kevin; Schwab, Jeffrey P; Eastwood, Daniel; Jackson, Scott; Ackman, Jeffrey D; Harris, Gerald F

    2009-10-01

    Upper extremity (UE) joint kinetics during aided ambulation is an area of research that is not well characterized in the current literature. Biped UE joints are not anatomically designed to be weight bearing, therefore it is important to quantify UE kinetics during assisted gait. This will help to better understand the biomechanical implications of UE weight bearing, and enable physicians to prescribe more effective methods for treatment and therapy, perhaps minimizing excessive loads and torques. To address this challenge, an UE model that incorporates both kinematics and kinetics has been developed for use with walkers instrumented with load cells. In this study, the UE joint kinetics are calculated for 10 children with cerebral palsy using both anterior and posterior walkers. Three-dimensional joint reaction forces and moments are fully characterized for the wrist, elbow, and shoulder (glenohumeral) joints for both walker types. Statistical analysis methods are used to quantify the differences in forces or moments between the two walker types. Comparisons showed no significant differences in kinetic joint parameters between walker types. Results from a power analysis of the current data are provided which may be useful for planning longer term clinical studies. If risk factors for UE joint pathology can be identified early, perhaps a change in gait training routine, walker prescription, or walker design could prevent further harm.

  19. Patients with triangular fibrocartilage complex injuries and distal radioulnar joint instability have reduced rotational torque in the forearm.

    PubMed

    Andersson, J K; Axelsson, P; Strömberg, J; Karlsson, J; Fridén, J

    2016-09-01

    A total of 20 patients scheduled for wrist arthroscopy, all with clinical signs of rupture to the triangular fibrocartilage complex and distal radioulnar joint instability, were tested pre-operatively by an independent observer for strength of forearm rotation. During surgery, the intra-articular pathology was documented by photography and also subsequently individually analysed by another independent hand surgeon. Arthroscopy revealed a type 1-B injury to the triangular fibrocartilage complex in 18 of 20 patients. Inter-rater reliability between the operating surgeon and the independent reviewer showed absolute agreement in all but one patient (95%) in terms of the injury to the triangular fibrocartilage complex and its classification. The average pre-operative torque strength was 71% of the strength of the non-injured contralateral side in pronation and supination. Distal radioulnar joint instability with an arthroscopically verified injury to the triangular fibrocartilage complex is associated with a significant loss of both pronation and supination torque. Case series, Level IV. © The Author(s) 2015.

  20. Analysis of kinematically redundant reaching movements using the equilibrium-point hypothesis.

    PubMed

    Cesari, P; Shiratori, T; Olivato, P; Duarte, M

    2001-03-01

    Six subjects performed a planar reaching arm movement to a target while unpredictable perturbations were applied to the endpoint; the perturbations consisted of pulling springs having different stiffness. Two conditions were applied; in the first, subjects had to reach for the target despite the perturbation, in the second condition, the subjects were asked to not correct the motion as a perturbation was applied. We analyzed the kinematics profiles of the three arm segments and, by means of inverse dynamics, calculated the joint torques. The framework of the equilibrium-point (EP) hypothesis, the lambda model, allowed the reconstruction of the control variables, the "equilibrium trajectories", in the "do not correct" condition for the wrist and the elbow joints as well as for the end point final position, while for the other condition, the reconstruction was less reliable. The findings support and extend to a multiple-joint planar movement, the paradigm of the EP hypothesis along with the "do not correct" instruction.

  1. The effects of music on pain perception of stroke patients during upper extremity joint exercises.

    PubMed

    Kim, Soo Ji; Koh, Iljoo

    2005-01-01

    The purpose of this study was to determine the effects of music therapy on pain perception of stroke patients during upper extremity joint exercises. Ten stroke patients (1 male and 9 females) ranging in age from 61 to 73 participated in the study. Music conditions used in the study consisted of: (a) song, (b) karaoke accompaniment (same music to condition A except singers' voices), and (c) no music. Exercise movements in this study included hand, wrist, and shoulder joints. During the 8-week period music therapy sessions, subjects repeated 3 conditions according to the randomized orders and subjects rated their perceived pain on a scale immediately after each condition. The General Linear Model (GLM) Repeated Measures ANOVA revealed that there were no significant differences in pain rating across the three music conditions. However, positive affects and verbal responses, while performing upper extremity exercises with both music and karaoke accompaniment music, were observed using video observations.

  2. Arthroscopically assisted reconstruction of triangular fibrocartilage complex foveal avulsion in the ulnar variance-positive patient.

    PubMed

    Kim, ByungSung; Yoon, Hong-Kee; Nho, Jae-Hwi; Park, Kang Hee; Park, Sung-Yong; Yoon, Jun-Hee; Song, Hyun Seok

    2013-11-01

    Our aim was to evaluate the clinical results of patients treated by arthroscopically assisted reconstruction of foveal avulsion injury of the triangular fibrocartilage complex (TFCC) using a suture anchor. We retrospectively reviewed the results of 15 patients (11 men and 4 women; mean age, 30.5 years) who underwent surgical procedures for the treatment of TFCC foveal avulsion at our hospital. The patients were followed up for a mean of 29 months. The patients had TFCC foveal avulsion caused by sprains (n = 8), falls (n = 4), playing baseball (n = 2), and a motor vehicle accident (n = 1). All the patients underwent magnetic resonance imaging. Radiographs obtained to assess ulnar variance (UV), ulnar-dorsal subluxation, and function of the wrist based on grip power; Disabilities of the Arm, Shoulder and Hand score; and Mayo wrist score were examined for all patients both preoperatively and postoperatively. On preoperative magnetic resonance imaging, TFCC foveal avulsion was observed in 13 of 15 cases. The mean UV value based on preoperative simple radiographic findings was 1.7 ± 1.0 mm, and dorsal subluxation at the distal ulna improved from 2.9 ± 3.0 mm to 0.2 ± 0.9 mm (P = .017). In all cases the distal radioulnar joint instability disappeared postoperatively. Grip power (compared with the uninvolved limb) was 79.3% preoperatively and 82.9% postoperatively (P = .086). The Disabilities of the Arm, Shoulder and Hand scores were 28.4 points preoperatively and 16.6 points postoperatively (P = .061). The Mayo wrist scores were excellent in 10 cases, good in 2, and fair in 3, and the mean score improved significantly from 64 points preoperatively to 84 points postoperatively (P = .007). Arthroscopic-assisted suture anchor reattachment of the TFCC in patients with traumatic TFCC foveal avulsion can prevent or reduce distal radioulnar joint instability and reduce pain even in chronic cases with positive UV. Level IV, therapeutic case series. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  3. Two-Armed, Mobile, Sensate Research Robot

    NASA Technical Reports Server (NTRS)

    Engelberger, J. F.; Roberts, W. Nelson; Ryan, David J.; Silverthorne, Andrew

    2004-01-01

    The Anthropomorphic Robotic Testbed (ART) is an experimental prototype of a partly anthropomorphic, humanoid-size, mobile robot. The basic ART design concept provides for a combination of two-armed coordination, tactility, stereoscopic vision, mobility with navigation and avoidance of obstacles, and natural-language communication, so that the ART could emulate humans in many activities. The ART could be developed into a variety of highly capable robotic assistants for general or specific applications. There is especially great potential for the development of ART-based robots as substitutes for live-in health-care aides for home-bound persons who are aged, infirm, or physically handicapped; these robots could greatly reduce the cost of home health care and extend the term of independent living. The ART is a fully autonomous and untethered system. It includes a mobile base on which is mounted an extensible torso topped by a head, shoulders, and two arms. All subsystems of the ART are powered by a rechargeable, removable battery pack. The mobile base is a differentially- driven, nonholonomic vehicle capable of a speed >1 m/s and can handle a payload >100 kg. The base can be controlled manually, in forward/backward and/or simultaneous rotational motion, by use of a joystick. Alternatively, the motion of the base can be controlled autonomously by an onboard navigational computer. By retraction or extension of the torso, the head height of the ART can be adjusted from 5 ft (1.5 m) to 6 1/2 ft (2 m), so that the arms can reach either the floor or high shelves, or some ceilings. The arms are symmetrical. Each arm (including the wrist) has a total of six rotary axes like those of the human shoulder, elbow, and wrist joints. The arms are actuated by electric motors in combination with brakes and gas-spring assists on the shoulder and elbow joints. The arms are operated under closed-loop digital control. A receptacle for an end effector is mounted on the tip of the wrist and contains a force-and-torque sensor that provides feedback for force (compliance) control of the arm. The end effector could be a tool or a robot hand, depending on the application.

  4. Analysis and comparison of wrist splint designs using the finite element method: Multi-material three-dimensional printing compared to typical existing practice with thermoplastics.

    PubMed

    Cazon, Aitor; Kelly, Sarah; Paterson, Abby M; Bibb, Richard J; Campbell, R Ian

    2017-09-01

    Rheumatoid arthritis is a chronic disease affecting the joints. Treatment can include immobilisation of the affected joint with a custom-fitting splint, which is typically fabricated by hand from low temperature thermoplastic, but the approach poses several limitations. This study focused on the evaluation, by finite element analysis, of additive manufacturing techniques for wrist splints in order to improve upon the typical splinting approach. An additive manufactured/3D printed splint, specifically designed to be built using Objet Connex multi-material technology and a virtual model of a typical splint, digitised from a real patient-specific splint using three-dimensional scanning, were modelled in computer-aided design software. Forty finite element analysis simulations were performed in flexion-extension and radial-ulnar wrist movements to compare the displacements and the stresses. Simulations have shown that for low severity loads, the additive manufacturing splint has 25%, 76% and 27% less displacement in the main loading direction than the typical splint in flexion, extension and radial, respectively, while ulnar values were 75% lower in the traditional splint. For higher severity loads, the flexion and extension movements resulted in deflections that were 24% and 60%, respectively, lower in the additive manufacturing splint. However, for higher severity loading, the radial defection values were very similar in both splints and ulnar movement deflection was higher in the additive manufacturing splint. A physical prototype of the additive manufacturing splint was also manufactured and was tested under normal conditions to validate the finite element analysis data. Results from static tests showed maximum displacements of 3.46, 0.97, 3.53 and 2.51 mm flexion, extension, radial and ulnar directions, respectively. According to these results, the present research argues that from a technical point of view, the additive manufacturing splint design stands at the same or even better level of performance in displacements and stress values in comparison to the typical low temperature thermoplastic approach and is therefore a feasible approach to splint design and manufacture.

  5. Hand anthropometry of Indian women.

    PubMed

    Nag, Anjali; Nag, P K; Desai, Hina

    2003-06-01

    Data on the physical dimension of the hand of Indian women are scanty. This information is necessary to ascertain human-machine compatibility in the design of manual systems for the bare and gloved hand, such as design and sizing of hand tools, controls, knobs and other applications in different kinds of precision and power grips. The present study was undertaken to generate hand anthropometric data of 95 women, working in informal industries (beedi, agarbatti and garment making). Fifty one hand measurements of the right hand (lengths, breadths, circumferences, depths, spreads and clearances of hand and fingers) were taken, using anthropometric sliding and spreading calipers, measuring tape and handgrip strength dynamometer. The data were statistically analyzed to determine the normality of data and the percentile values of different hand dimensions, and simple and multiple regression analysis were done to determine better predictors of hand length and grip strength. The hand breadths, circumferences and depths were approximately normally distributed, with some deviation in case of the finger lengths. Hand length was significantly correlated with the fist, wrist and finger circumferences. The fist and wrist circumferences, in combination, were better predictors of hand length. The hand lengths, breadths and depths, including finger joints of the Indian women studied were smaller than those of American, British and West Indian women. The hand circumferences of the Indian women were also smaller than the American women. Grip strengths of Indian women (20.36 +/- 3.24 kg) were less than those of American, British and West Indian women. Grip strength was found to be statistically significant with hand dimensions, such as hand height perpendicular to wrist crease (digit 5), proximal interphalangeal joint breadth (digit 3) and hand spread across wedge 1. The women who are forced to frequently use cutters, strippers and other tools, which are not optimally designed to their hand dimensions and strength range, might have higher prevalence of clinical symptoms and disorders of the hand. In view of the human hand-tool interface requirements, the present data on Indian women would be useful for ergo-design applications of hand tools and devices.

  6. Assessment of posture and joint movements of the upper limbs of patients after mastectomy and lymphadenectomy

    PubMed Central

    Haddad, Cinira Assad Simão; Saad, Marcelo; Perez, Maria del Carmen Janeiro; Miranda, Fausto

    2013-01-01

    ABSTRACT Objective: To evaluate alterations in posture and range of motion of the upper limbs in women after mastectomy and lymphadenectomy, submitted to radiotherapy as adjuvant treatment. Methods: Two groups were evaluated: 16 post-mastectomy women with lymphedema of the upper limb and 14 post-mastectomy women without lymphedema. Patients were submitted to analysis made by software, one for posture and the other to measure ranges of movement of the shoulder, elbow, and wrists. The results obtained were compared between the right and left sides, and operated and non-operated sides, and then were submitted to statistical tests. Results: Both groups presented with anteriorization of the trunk. The women with lymphedema had head rotation to the right, protrusion of the left shoulder, and trunk inclination angle smaller on the operated side, besides bilateral elevation of the scapula when compared to the group with no lymphedema. Changes in range of motion were also smaller on the operated side in terms of flexion, abduction, and external rotation of the shoulder for all women, and for those with lymphedema, elbow extension and wrist flexion had a smaller range of motion. Conclusion: Women submitted to mastectomy presented with asymmetries and modifications in posture, and lymphedema seemed to worsen this condition. Additionally, they had deficits in range of motion in the shoulders on the operated side. Women with lymphedema also showed deficits in the elbows and wrist. PMID:24488379

  7. Ultrasonography and detection of subclinical joints and tendons involvements in Systemic Lupus erythematosus (SLE) patients: A cross-sectional multicenter study.

    PubMed

    Salliot, Carine; Denis, Amélie; Dernis, Emmanuelle; Andre, Vincent; Perdriger, Aleth; Albert, Jean-David; Mammou Mraghni, Saloua; Griffoul-Espitalier, Isabelle; Hamidou, Mohamed; Le Goff, Benoit; Joulin, Sandrine Jousse; Marhadour, Thierry; Richez, Christophe; Poursac, Nicolas; Lazaro, Estebaliz; Rist, Stéphanie; Corondan, Anca; Quinten, Clara; Martaillé, Virginie; Valéry, Antoine; Ducourau, Emilie

    2018-02-15

    The aims of this study in SLE population were (1) to describe ultrasonography (US) joint abnormalities, (2) to estimate the reliability of clinical swollen joint count (C-SJC) and SLEDAI (C-SLEDAI) versus US-SJC and US-SLEDAI scores, (3) to highlight specific patterns of lupus patients with Power Doppler (PD) abnormalities. For this cross-sectional multicenter study, 151 consecutive adult SLE patients were recruited. Evaluation included a clinical standardized joint assessment, B-mode and PD US of 40 joints and 26 tendons blinded for clinical examination. Reliability and agreement between clinical and B-mode US were calculated using the intraclass correlation coefficients (ICC [95% Confidence Interval]). We found a very high frequency of subclinical US abnormalities in asymptomatic patients: 85% of patients without joint symptoms had at least 1 US abnormality. Among them 46 patients (87%) had a history of joint involvement. The most frequent abnormalities were joint effusmaions (108 patients), synovial hypertrophy (SH, 109 patients) and synovitis (61 patients). Joint or tendon PD signal (grade>1) was found in 44% of patients (67/151). Synovitis were mainly located especially on MCPs and wrists. Even if reliability between clinical and grey-scale US SJC assessments was poor, reliability between clinical and US SLEDAI was good. Comparison between SLE patients with and without PD signal did not show any specific SLE pattern. US may be useful to assess joint involvement in SLE patients but did not significantly change SLEDAI score. Copyright © 2018. Published by Elsevier SAS.

  8. Remitting seronegative symmetrical synovitis with pitting edema (RS3PE) associated with partial melanoma response under anti-CTLA-4 and anti-PD-1 combination.

    PubMed

    Amini-Adle, Mona; Piperno, Muriel; Tordo, Jérémie; Dubois, Valérie; Marabelle, Aurélien; Thomas, Luc; Dalle, Stéphane

    2018-03-26

    The patient, a-70-year-old male developed severe inflammatory polyarthritis associated with diffuse pitting edema in the hands and feet (A) six weeks after the initiation of ipilimumab and nivolumab for a heavily metastatic melanoma (B). Synovitis was present in wrists, metacarpophalangeal, and proximal interphalangeal joints. C-reactive protein level was elevated (169 comparing to 7 before immunotherapy introduction). This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  9. Clinical and ultrasound findings in patients with calcium pyrophosphate dihydrate deposition disease.

    PubMed

    Vele, Paulina; Simon, Siao-Pin; Damian, Laura; Felea, Ioana; Muntean, Laura; Filipescu, Ileana; Rednic, Simona

    2018-05-02

    To evaluate the presence and distribution of calcium pyrophosphate (CPP) deposits in joints commonly affected by CPP deposition (CPPD) disease (acromio-clavicular, gleno-humeral, wrists, hips, knees, ankles, and symphysis pubis joints) using ultrasound (US). Thirty consecutive patients fulfilling McCarty diagnostic criteria for CPPD were consecutively enrolled in the study. The data registered using the US included the affected joints, the calcification site, and the pattern of calcification (thin hyperechoic bands, parallel to the surface of the hyaline cartilage, hyperechoic spots, and hyperechoic nodular or oval deposits). The presence of CPP crystals in knees was confirmed by polarized light microscopy examination of the synovial fluid and radiographs of the knees were performed in all patients. In 30 patients, 390 joints were scanned, (13 joints in every patient). The mean±standard deviation number of joints with US CPPD evidence per patient was 2.93±1.8 (range 1-9). The knee was the most common joint involved both clinically and using US examination. The second US pattern (with hyperechoic spots) was the most frequent. Fibrocartilage calcifications were more common than hyaline calcification. Using radiography as reference method, the sensitivity and specificity of US for diagnosis CPPD in knees was 79.31%, 95CI(66.65%-88.83%), and 14.29%, 95CI(1.78%-42.81%), respectively. The knee is the most frequent joint affected by CPPD. The second ultrasound pattern is the most common. CPPD affects the fibrocartilage to a greater extent than the hyaline cartilage.

  10. Wrist postures and forces in tree planters during three tree unloading conditions.

    PubMed

    Denbeigh, Kathleen; Slot, Tegan R; Dumas, Geneviève A

    2013-01-01

    The aims of this study were to investigate wrist postures and forces while operating the shovel during tree planting and to determine if different tree unloading techniques result in variations in wrist postures and forces. Experienced tree planters performed the planting task in a laboratory environment for three conditions: (1) symmetric tree unloading, and asymmetric unloading resulting in (2) right-loaded planting bags and (3) left-loaded planting bags. An optoelectric system and a shovel instrumented with strain gauges captured wrist posture and forces at the wrist, respectively. Wrist extension of up to 45° was observed, and this posture, in combination with varying degrees of wrist deviation, may be a primary risk factor for musculoskeletal pain. Average resultant forces at the wrist were moderately high (>30 N) for each unloading condition, indicating increased risk for the development of repetitive strain injuries such as carpal tunnel syndrome. No significant differences in wrist posture or forces existed between unloading conditions. Wrist pain is a major musculoskeletal complaint among tree planters. This study measured wrist postures and forces at the wrist while operating the shovel during tree planting. The wrist extension observed, in combination with deviation, may be a key risk factor for musculoskeletal pain. Forces at the wrist indicate increased risk for repetitive strain injuries.

  11. Magnetic resonance imaging of the hand and wrist in a randomized, double-blind, multicenter, placebo-controlled trial of infliximab for rheumatoid arthritis: Comparison of dynamic contrast enhanced assessments with semi-quantitative scoring

    PubMed Central

    Baumgartner, Richard; Peterfy, Charles; Balanescu, Andra; Mirea, Gavrila; Harabagiu, Alexandru; Popa, Serghei; Cheng, Amy; Feng, Dai; Ashton, Edward; DiCarlo, Julie; Vallee, Marie-Helene; Dardzinski, Bernard J.

    2017-01-01

    The objective of this study was to compare the scope and the discriminative power of Dynamic Contrast Enhanced Magnetic Resonance Imaging (DCE-MRI) to those of semi-quantitative MRI scoring for evaluating treatments for rheumatoid arthritis (RA) in multicenter randomized clinical trials (RCTs). Sixty-one patients with active RA participated in a double-blind, parallel group, randomized, multicenter methodology study receiving infliximab or placebo through 14 weeks. The most symptomatic wrist and metacarpophalangeal joints (MCPs) were imaged using MRI. In addition to clinical assessments with DAS28(CRP), the severity of inflammation was measured as synovial leak of gadolinium based contrast agent (GBCA) using DCE-MRI (Ktrans, primary endpoint) at weeks 0, 2, 4, and 14. Two radiologists independently scored synovitis, osteitis and erosion using RA MRI Score (RAMRIS) and cartilage loss using a 9-point MRI scale (CARLOS). Infliximab showed greater decrease from baseline in DAS28(CRP), DCE-MRI Ktrans of wrist and MCP synovium, and RAMRIS synovitis and osteitis at all visits compared with placebo (p<0.001). Treatment effect sizes of infliximab therapy were similar for DAS28(CRP) (1.08; 90% CI (0.63–1.53)) and MRI inflammation endpoints: wrist Ktrans (1.00 (0.55–1.45)), RAMRIS synovitis (0.85 (0.38–1.28)) and RAMRIS osteitis (0.99 (0.52–1.43)). Damage measures of bone erosion (RAMRIS) and cartilage loss (CARLOS) were reduced with infliximab compared to with placebo at 14 weeks (p≤0.025). DCE-MRI and RAMRIS were equally sensitive and responsive to the anti-inflammatory effects of infliximab. RAMRIS and CARLOS showed suppression of erosion and cartilage loss, respectively, at 14 weeks. (ClinicalTrials.gov registration: NCT01313520) PMID:29236711

  12. Quantifying Forearm Muscle Activity during Wrist and Finger Movements by Means of Multi-Channel Electromyography

    PubMed Central

    Gazzoni, Marco; Celadon, Nicolò; Mastrapasqua, Davide; Paleari, Marco; Margaria, Valentina; Ariano, Paolo

    2014-01-01

    The study of hand and finger movement is an important topic with applications in prosthetics, rehabilitation, and ergonomics. Surface electromyography (sEMG) is the gold standard for the analysis of muscle activation. Previous studies investigated the optimal electrode number and positioning on the forearm to obtain information representative of muscle activation and robust to movements. However, the sEMG spatial distribution on the forearm during hand and finger movements and its changes due to different hand positions has never been quantified. The aim of this work is to quantify 1) the spatial localization of surface EMG activity of distinct forearm muscles during dynamic free movements of wrist and single fingers and 2) the effect of hand position on sEMG activity distribution. The subjects performed cyclic dynamic tasks involving the wrist and the fingers. The wrist tasks and the hand opening/closing task were performed with the hand in prone and neutral positions. A sensorized glove was used for kinematics recording. sEMG signals were acquired from the forearm muscles using a grid of 112 electrodes integrated into a stretchable textile sleeve. The areas of sEMG activity have been identified by a segmentation technique after a data dimensionality reduction step based on Non Negative Matrix Factorization applied to the EMG envelopes. The results show that 1) it is possible to identify distinct areas of sEMG activity on the forearm for different fingers; 2) hand position influences sEMG activity level and spatial distribution. This work gives new quantitative information about sEMG activity distribution on the forearm in healthy subjects and provides a basis for future works on the identification of optimal electrode configuration for sEMG based control of prostheses, exoskeletons, or orthoses. An example of use of this information for the optimization of the detection system for the estimation of joint kinematics from sEMG is reported. PMID:25289669

  13. Magnetic resonance imaging of the hand and wrist in a randomized, double-blind, multicenter, placebo-controlled trial of infliximab for rheumatoid arthritis: Comparison of dynamic contrast enhanced assessments with semi-quantitative scoring.

    PubMed

    Beals, Chan; Baumgartner, Richard; Peterfy, Charles; Balanescu, Andra; Mirea, Gavrila; Harabagiu, Alexandru; Popa, Serghei; Cheng, Amy; Feng, Dai; Ashton, Edward; DiCarlo, Julie; Vallee, Marie-Helene; Dardzinski, Bernard J

    2017-01-01

    The objective of this study was to compare the scope and the discriminative power of Dynamic Contrast Enhanced Magnetic Resonance Imaging (DCE-MRI) to those of semi-quantitative MRI scoring for evaluating treatments for rheumatoid arthritis (RA) in multicenter randomized clinical trials (RCTs). Sixty-one patients with active RA participated in a double-blind, parallel group, randomized, multicenter methodology study receiving infliximab or placebo through 14 weeks. The most symptomatic wrist and metacarpophalangeal joints (MCPs) were imaged using MRI. In addition to clinical assessments with DAS28(CRP), the severity of inflammation was measured as synovial leak of gadolinium based contrast agent (GBCA) using DCE-MRI (Ktrans, primary endpoint) at weeks 0, 2, 4, and 14. Two radiologists independently scored synovitis, osteitis and erosion using RA MRI Score (RAMRIS) and cartilage loss using a 9-point MRI scale (CARLOS). Infliximab showed greater decrease from baseline in DAS28(CRP), DCE-MRI Ktrans of wrist and MCP synovium, and RAMRIS synovitis and osteitis at all visits compared with placebo (p<0.001). Treatment effect sizes of infliximab therapy were similar for DAS28(CRP) (1.08; 90% CI (0.63-1.53)) and MRI inflammation endpoints: wrist Ktrans (1.00 (0.55-1.45)), RAMRIS synovitis (0.85 (0.38-1.28)) and RAMRIS osteitis (0.99 (0.52-1.43)). Damage measures of bone erosion (RAMRIS) and cartilage loss (CARLOS) were reduced with infliximab compared to with placebo at 14 weeks (p≤0.025). DCE-MRI and RAMRIS were equally sensitive and responsive to the anti-inflammatory effects of infliximab. RAMRIS and CARLOS showed suppression of erosion and cartilage loss, respectively, at 14 weeks. (ClinicalTrials.gov registration: NCT01313520).

  14. "Dangerous" anatomic varieties of recurrent motor branch of median nerve.

    PubMed

    Elsaftawy, Ahmed; Gworys, Bohdan; Jabłecki, Jerzy; Szajerka, Tobiasz

    2013-08-01

    Carpal tunnel release became one of the most common operations in the field of hand surgery. Many controversies has been made about frequency of the so-called dangerous variations of motor branch of the median nerve. Knowledge of all the anatomical variations motor branches is the duty of every surgeon dealing with the subject. The aim of the study was to present the incidence of dangerous variants of median nerve motor branch in the carpal tunnel based on both clinical experience and anatomical studies performed on 20 cadaver wrists. Between 2006-2012 during minimally open carpal tunnel release we made photographic documentation of all visible dangerous varieties of recurrent motor branches of the median nerve. We also studied 20 cadaver wrists in the Department of Anatomy Medical University in Wrocław. Dangerous varieties of the motor branch of median nerve was found in three clinical cases and in one cadaver wrist. Also In one wrist we found one regular branche, which, however, has atypical two separate branches supplying the thenar muscles. Dangerous varieties of the motor branch of median nerve occur very rare in the population, but does not release from the fact that in each case special attention must be given.We also conclude that, at the minimally open carpal tunnel release procedure, the transverse carpal ligament should be released rather from the line of radial border of the 4th finger to minimize the risk of injury to the recurrent motor branch of median nerve.

  15. New method for evaluation of cervical vertebral maturation based on angular measurements.

    PubMed

    Alhadlaq, Adel M; Al-Shayea, Eman I

    2013-04-01

    To investigate the validity of a new approach to assess the cervical vertebral maturation based on angular measurements of the lower border concavity of cervical vertebral bodies. Hand-wrist and lateral cephalometric radiographs of 197 male subjects with age range of 10-15 years attending the orthodontic clinic at King Saud University, Riyadh, Kingdom of Saudi Arabia were utilized. The study was carried out between September 2009 and May 2011. The study sample was divided into 6 groups (group 1: 10 years to group 6: 15 years) based on the chronological age of the subject. The skeletal age of the subjects was determined using Greulich and Pyle's standard radiographic atlas, and skeletal maturation was assessed by Fishman's skeletal maturity indicators. The cervical vertebral maturation (CVM) of subjects was determined using angular measurements of the second, third, and fourth cervical vertebral bodies. The validity of the newly developed method was assessed by examining the correlation between CVM stages determined by the angular measurements and the skeletal maturation level as determined by the standard hand-wrist methods. A significant correlation (r=0.94) was found between the angular CVM stages and the skeletal age determined by Greulich and Pyle's atlas from hand-wrist radiographs. Also, a high correlation (r=0.94) was found between the angular CVM stages and the Fishman's hand-wrist skeletal maturity indicators. The new angular measurement approach to determine CVM is valid and has the potential to be applied in assessing skeletal maturity level in growing male children.

  16. Accuracy of digital arm and wrist manometers: clinical implications for the dental hygienist.

    PubMed

    Furgeson, Danielle; Mickels-Foster, Nancy

    2013-10-01

    Utilization of digital manometers chairside is fast becoming a standard of care in dental hygiene education. It is imperative to ensure accurate blood pressure measurements regardless of modality to avoid medical emergencies in the dental chair. This study sought to determine the accuracy of the automated digital arm and wrist cuffs utilized by students in the University of Maine at Augusta, Bangor Campus Dental Health Programs' dental hygiene clinic. After institutional review board approval, 121 subjects were recruited, with 21 excluded for a total of 100 subjects. Subjects were randomly assigned to different test modalities upon check-in. Initial blood pressure measurements were taken with a calibrated aneroid control device by a principal investigator. A second measurement was taken with the randomized arm or wrist manometer 5 minutes later. Investigators were blinded to the modality of test manometer and measurements obtained from the second reading. All readings were taken according to manufacturers' instructions to ensure technique consistency. Data indicated lower readings for each modality from the control for both systolic and diastolic measurements. The differences in the systolic and diastolic readings for the wrist modality were significantly lower than the control with (p= 0.000) and (p=0.000), respectively. Automated digital manometers should be used with caution as a screening tool in the dental setting, particularly when administration of pharmacological agents such as local anesthesia may be used during the course of treatment. These automated modalities should not be used for patients with cardiac or hypertensive conditions.

  17. Quantification of shoulder and elbow passive moments in the sagittal plane as a function of adjacent angle fixations.

    PubMed

    Kodek, Timotej; Munih, Marko

    2003-01-01

    The goal of this study was an assessment of the shoulder and elbow joint passive moments in the sagittal plane for six healthy individuals. Either the shoulder or elbow joints were moved at a constant speed, very slowly throughout a large portion of their range by means of an industrial robot. During the whole process the arm was held fully passively, while the end point force data and the shoulder, elbow and wrist angle data were collected. The presented method unequivocally reveals a large passive moment adjacent angle dependency in the central angular range, where most everyday actions are performed. It is expected to prove useful in the future work when examining subjects with neuromuscular disorders. Their passive moments may show a fully different pattern than the ones obtained in this study.

  18. All Madelung deformities are not endocrine

    PubMed Central

    Kumar, Ajay; Rai, Gopal K.; Akhtar, Javed; Phillip, Rajeev; Gutch, Manish; Arya, T. V. S.

    2013-01-01

    Madelung deformity is a rare inherited disorder associated with endocrine disorders like Turner's syndrome, pseudohypoparathyroidism, but can be seen with short stature homeobox deficiency conditions such as Leri-Weill dyschondrosteosis (LWD) and Langers mesomelic dysplasia. It has also been reported following trauma to the distal radius epiphysis neoplasia mucopolysaccharidosis (MPS) and achondroplasia. Madelung deformity is an abnormality of distal radial epiphysis where in progressive ulnar and volar tilt of the articular surface occurring in association with distal subluxation of ulna. A 13-year-old girl was referred to us for evaluation of bilateral deformity of wrist and short stature. There was ulnar deviation and dorsal tilt of bilateral hands without history of pain to the joint trauma and family history of similar illness. On X-ray, wrist showed malformed distal radial epiphysis with dorsal and ulnar shift and with increased length of phalanges suggestive of Madelung deformity. X-ray spine was normal. Ultrasound abdomen showed normal uterus and ovary and her follicle stimulating hormone. Luteinizing hormone was normal and so was urine MPS screening. Based on the above points the diagnosis of LWD was made. PMID:24251169

  19. All Madelung deformities are not endocrine.

    PubMed

    Kumar, Ajay; Rai, Gopal K; Akhtar, Javed; Phillip, Rajeev; Gutch, Manish; Arya, T V S

    2013-10-01

    Madelung deformity is a rare inherited disorder associated with endocrine disorders like Turner's syndrome, pseudohypoparathyroidism, but can be seen with short stature homeobox deficiency conditions such as Leri-Weill dyschondrosteosis (LWD) and Langers mesomelic dysplasia. It has also been reported following trauma to the distal radius epiphysis neoplasia mucopolysaccharidosis (MPS) and achondroplasia. Madelung deformity is an abnormality of distal radial epiphysis where in progressive ulnar and volar tilt of the articular surface occurring in association with distal subluxation of ulna. A 13-year-old girl was referred to us for evaluation of bilateral deformity of wrist and short stature. There was ulnar deviation and dorsal tilt of bilateral hands without history of pain to the joint trauma and family history of similar illness. On X-ray, wrist showed malformed distal radial epiphysis with dorsal and ulnar shift and with increased length of phalanges suggestive of Madelung deformity. X-ray spine was normal. Ultrasound abdomen showed normal uterus and ovary and her follicle stimulating hormone. Luteinizing hormone was normal and so was urine MPS screening. Based on the above points the diagnosis of LWD was made.

  20. Pseudogout of the cervical and thoracic spine mimicking infection after lumbar fusion: case report.

    PubMed

    Bridges, Kelly J; Bullis, Carli L; Wanchu, Ajay; Than, Khoi D

    2017-08-01

    Pseudogout is a form of acute calcium pyrophosphate deposition (CPPD) disease that typically afflicts the elderly. CPPD commonly involves larger joints, such as the knees, wrists, shoulders, and hips, and has been known to involve the spine. The authors report the case of a 66-year-old woman with a recent history of lumbar laminectomy and fusion who presented 5 weeks postprocedure with a clinical and radiographic picture consistent with multilevel skip lesions involving the cervical and thoracic spine, thoracic discitis, and epidural abscess. Serial blood cultures and repeat biopsy samples were sterile. Subsequent wrist and ankle erythema, pain, and swelling led to synovial fluid analysis, and pseudogout was diagnosed. She was treated with an interleukin-1 inhibitor with immediate symptom relief. To the authors' knowledge, this is only the second report of spinal pseudogout presenting with a clinical and radiographic picture consistent with discitis and epidural abscess. This report is the first to report skip lesions of pseudogout occurring throughout the spine that are uniquely remote from a recent lumbar surgery.

  1. Design and kinematic analysis of a novel upper limb exoskeleton for rehabilitation of stroke patients.

    PubMed

    Zeiaee, Amin; Soltani-Zarrin, Rana; Langari, Reza; Tafreshi, Reza

    2017-07-01

    This paper details the design process and features of a novel upper limb rehabilitation exoskeleton named CLEVER (Compact, Low-weight, Ergonomic, Virtual/Augmented Reality Enhanced Rehabilitation) ARM. The research effort is focused on designing a lightweight and ergonomic upper-limb rehabilitation exoskeleton capable of producing diverse and perceptually rich training scenarios. To this end, the knowledge available in the literature of rehabilitation robotics is used along with formal conceptual design techniques. This paper briefly reviews the systematic approach used for design of the exoskeleton, and elaborates on the specific details of the proposed design concept and its advantages over other design possibilities. The kinematic structure of CLEVER ARM has eight degrees of freedom supporting the motion of shoulder girdle, glenohumeral joint, elbow and wrist. Six degrees of freedom of the exoskeleton are active, and the two degrees of freedom supporting the wrist motion are passive. Kinematics of the proposed design is studied analytically and experimentally with the aid of a 3D printed prototype. The paper is concluded by some remarks on the optimization of the design, motorization of device, and the fabrication challenges.

  2. Tendon rupture associated with excessive smartphone gaming.

    PubMed

    Gilman, Luke; Cage, Dori N; Horn, Adam; Bishop, Frank; Klam, Warren P; Doan, Andrew P

    2015-06-01

    Excessive use of smartphones has been associated with injuries. A 29-year-old, right hand-dominant man presented with chronic left thumb pain and loss of active motion from playing a Match-3 puzzle video game on his smartphone all day for 6 to 8 weeks. On physical examination, the left extensor pollicis longus tendon was not palpable, and no tendon motion was noted with wrist tenodesis. The thumb metacarpophalangeal range of motion was 10° to 80°, and thumb interphalangeal range of motion was 30° to 70°. The clinical diagnosis was rupture of the left extensor pollicis longus tendon. The patient subsequently underwent an extensor indicis proprius (1 of 2 tendons that extend the index finger) to extensor pollicis longus tendon transfer. During surgery, rupture of the extensor pollicis longus tendon was seen between the metacarpophalangeal and wrist joints. The potential for video games to reduce pain perception raises clinical and social considerations about excessive use, abuse, and addiction. Future research should consider whether pain reduction is a reason some individuals play video games excessively, manifest addiction, or sustain injuries associated with video gaming.

  3. Prediction of Imagined Single-Joint Movements in a Person with High Level Tetraplegia

    PubMed Central

    Simeral, John D.; Donoghue, John P.; Hochberg, Leigh R.; Kirsch, Robert F.

    2013-01-01

    Cortical neuroprostheses for movement restoration require developing models for relating neural activity to desired movement. Previous studies have focused on correlating single-unit activities (SUA) in primary motor cortex to volitional arm movements in able-bodied primates. The extent of the cortical information relevant to arm movements remaining in severely paralyzed individuals is largely unknown. We record intracortical signals using a microelectrode array chronically implanted in the precentral gyrus of a person with tetraplegia, and estimate positions of imagined single-joint arm movements. Using visually guided motor imagery, the participant imagined performing eight distinct single-joint arm movements while SUA, multi-spike trains (MSP), multi-unit activity (MUA), and local field potential time (LFPrms) and frequency signals (LFPstft) were recorded. Using linear system identification, imagined joint trajectories were estimated with 20 – 60% variance explained, with wrist flexion/extension predicted the best and pronation/supination the poorest. Statistically, decoding of MSP and LFPstft yielded estimates that equaled those of SUA. Including multiple signal types in a decoder increased prediction accuracy in all cases. We conclude that signals recorded from a single restricted region of the precentral gyrus in this person with tetraplegia contained useful information regarding the intended movements of upper extremity joints. PMID:22851229

  4. Mental rotation of tactile stimuli: using directional haptic cues in mobile devices.

    PubMed

    Gleeson, Brian T; Provancher, William R

    2013-01-01

    Haptic interfaces have the potential to enrich users' interactions with mobile devices and convey information without burdening the user's visual or auditory attention. Haptic stimuli with directional content, for example, navigational cues, may be difficult to use in handheld applications; the user's hand, where the cues are delivered, may not be aligned with the world, where the cues are to be interpreted. In such a case, the user would be required to mentally transform the stimuli between different reference frames. We examine the mental rotation of directional haptic stimuli in three experiments, investigating: 1) users' intuitive interpretation of rotated stimuli, 2) mental rotation of haptic stimuli about a single axis, and 3) rotation about multiple axes and the effects of specific hand poses and joint rotations. We conclude that directional haptic stimuli are suitable for use in mobile applications, although users do not naturally interpret rotated stimuli in any one universal way. We find evidence of cognitive processes involving the rotation of analog, spatial representations and discuss how our results fit into the larger body of mental rotation research. For small angles (e.g., less than 40 degree), these mental rotations come at little cost, but rotations with larger misalignment angles impact user performance. When considering the design of a handheld haptic device, our results indicate that hand pose must be carefully considered, as certain poses increase the difficulty of stimulus interpretation. Generally, all tested joint rotations impact task difficulty, but finger flexion and wrist rotation interact to greatly increase the cost of stimulus interpretation; such hand poses should be avoided when designing a haptic interface.

  5. Grizzly bear (Ursus arctos horribilis) locomotion: forelimb joint mechanics across speed in the sagittal and frontal planes.

    PubMed

    Shine, Catherine L; Robbins, Charles T; Nelson, O Lynne; McGowan, Craig P

    2017-04-01

    The majority of terrestrial locomotion studies have focused on parasagittal motion and paid less attention to forces or movement in the frontal plane. Our previous research has shown that grizzly bears produce higher medial ground reaction forces (lateral pushing from the animal) than would be expected for an upright mammal, suggesting frontal plane movement may be an important aspect of their locomotion. To examine this, we conducted an inverse dynamics analysis in the sagittal and frontal planes, using ground reaction forces and position data from three high-speed cameras of four adult female grizzly bears. Over the speed range collected, the bears used walks, running walks and canters. The scapulohumeral joint, wrist and the limb overall absorb energy (average total net work of the forelimb joints, -0.97 W kg -1 ). The scapulohumeral joint, elbow and total net work of the forelimb joints have negative relationships with speed, resulting in more energy absorbed by the forelimb at higher speeds (running walks and canters). The net joint moment and power curves maintain similar patterns across speed as in previously studied species, suggesting grizzly bears maintain similar joint dynamics to other mammalian quadrupeds. There is no significant relationship with net work and speed at any joint in the frontal plane. The total net work of the forelimb joints in the frontal plane was not significantly different from zero, suggesting that, despite the high medial ground reaction forces, the forelimb acts as a strut in that plane. © 2017. Published by The Company of Biologists Ltd.

  6. Inverse Kinematics for Upper Limb Compound Movement Estimation in Exoskeleton-Assisted Rehabilitation.

    PubMed

    Cortés, Camilo; de Los Reyes-Guzmán, Ana; Scorza, Davide; Bertelsen, Álvaro; Carrasco, Eduardo; Gil-Agudo, Ángel; Ruiz-Salguero, Oscar; Flórez, Julián

    2016-01-01

    Robot-Assisted Rehabilitation (RAR) is relevant for treating patients affected by nervous system injuries (e.g., stroke and spinal cord injury). The accurate estimation of the joint angles of the patient limbs in RAR is critical to assess the patient improvement. The economical prevalent method to estimate the patient posture in Exoskeleton-based RAR is to approximate the limb joint angles with the ones of the Exoskeleton. This approximation is rough since their kinematic structures differ. Motion capture systems (MOCAPs) can improve the estimations, at the expenses of a considerable overload of the therapy setup. Alternatively, the Extended Inverse Kinematics Posture Estimation (EIKPE) computational method models the limb and Exoskeleton as differing parallel kinematic chains. EIKPE has been tested with single DOF movements of the wrist and elbow joints. This paper presents the assessment of EIKPE with elbow-shoulder compound movements (i.e., object prehension). Ground-truth for estimation assessment is obtained from an optical MOCAP (not intended for the treatment stage). The assessment shows EIKPE rendering a good numerical approximation of the actual posture during the compound movement execution, especially for the shoulder joint angles. This work opens the horizon for clinical studies with patient groups, Exoskeleton models, and movements types.

  7. An Extended Passive Motion Paradigm for Human-Like Posture and Movement Planning in Redundant Manipulators

    PubMed Central

    Tommasino, Paolo; Campolo, Domenico

    2017-01-01

    A major challenge in robotics and computational neuroscience is relative to the posture/movement problem in presence of kinematic redundancy. We recently addressed this issue using a principled approach which, in conjunction with nonlinear inverse optimization, allowed capturing postural strategies such as Donders' law. In this work, after presenting this general model specifying it as an extension of the Passive Motion Paradigm, we show how, once fitted to capture experimental postural strategies, the model is actually able to also predict movements. More specifically, the passive motion paradigm embeds two main intrinsic components: joint damping and joint stiffness. In previous work we showed that joint stiffness is responsible for static postures and, in this sense, its parameters are regressed to fit to experimental postural strategies. Here, we show how joint damping, in particular its anisotropy, directly affects task-space movements. Rather than using damping parameters to fit a posteriori task-space motions, we make the a priori hypothesis that damping is proportional to stiffness. This remarkably allows a postural-fitted model to also capture dynamic performance such as curvature and hysteresis of task-space trajectories during wrist pointing tasks, confirming and extending previous findings in literature. PMID:29249954

  8. The impact of shoulder abduction loading on EMG-based intention detection of hand opening and closing after stroke.

    PubMed

    Lan, Yiyun; Yao, Jun; Dewald, Julius P A

    2011-01-01

    Many stroke patients are subject to limited hand functions in the paretic arm due to a significant loss of Corticospinal Tract (CST) fibers. A possible solution for this problem is to classify surface Electromyography (EMG) signals generated by hand movements and uses that to implement Functional Electrical Stimulation (FES). However, EMG usually presents an abnormal muscle coactivation pattern shown as increased coupling between muscles within and/or across joints after stroke. The resulting Abnormal Muscle Synergies (AMS) could make the classification more difficult in individuals with stroke, especially when attempting to use the hand together with other joints in the paretic arm. Therefore, this study is aimed at identifying the impact of AMS following stroke on EMG pattern recognition between two hand movements. In an effort to achieve this goal, 7 chronic hemiparetic chronic stroke subjects were recruited and asked to perform hand opening and closing movements at their paretic arm while being either fully supported by a virtual table or loaded with 25% of subject's maximum shoulder abduction force. During the execution of motor tasks EMG signals from the wrist flexors and extensors were simultaneously acquired. Our results showed that increased synergy-induced activity at elbow flexors, induced by increasing shoulder abduction loading, deteriorated the performance of EMG pattern recognition for hand opening for those with a weak grasp strength and EMG activity. However, no such impact on hand closing has yet been observed possibly because finger/wrist flexion is facilitated by the shoulder abduction-induced flexion synergy.

  9. Immediate Biomechanical Implications of Transfer Component Skills Training on Independent Wheelchair Transfers.

    PubMed

    Tsai, Chung-Ying; Boninger, Michael L; Hastings, Jennifer; Cooper, Rory A; Rice, Laura; Koontz, Alicia M

    2016-10-01

    To evaluate the immediate effects of transfer training based on the Transfer Assessment Instrument (TAI) on the upper limb biomechanics during transfers. Pre-post intervention. Biomechanics laboratory. Full-time manual wheelchair users (N=24) performed 5 transfers to a level height bench, while their natural transfer skills were scored using the TAI, and their biomechanical data were recorded. Participants with 2 or more component skill deficits were invited to return to receive personalized transfer training. TAI part 1 summary scores and biomechanical variables calculated at the shoulder, elbow, and wrist joints were compared before and immediately after transfer training. Sixteen of the 24 manual wheelchair users met the criteria for training, and 11 manual wheelchair users came back for the revisit. Their TAI part 1 summary scores improved from 6.31±.98 to 9.92±.25. They had significantly smaller elbow range of motion, shoulder resultant moment, and rates of rise of elbow and wrist resultant forces on their trailing side during transfers after training (P<.05). On the leading side, shoulder maximum internal rotation and elevation angles, and shoulder resultant moments and rates of rise of shoulder resultant force and moment decreased after training (P<.04). The TAI-based training showed short-term beneficial biomechanical effects on wheelchair users' upper limbs, such as better shoulder positioning and lower joint loadings. If the skills are practiced longer-term, they may help protect the upper limbs from developing pain and injuries. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  10. Reconfiguration of the upper extremity relative to the pushrim affects load distribution during wheelchair propulsion.

    PubMed

    Munaretto, Joseph M; McNitt-Gray, Jill L; Flashner, Henryk; Requejo, Philip S

    2013-08-01

    Repetitive loading during manual wheelchair propulsion (WCP) is associated with overuse injury to the upper extremity (UE). The aim of this study was to determine how RF redirection and load distribution are affected by changes upper extremity kinematic modifications associated with modifications in seat positions during a WCP task. The aim of this study was to determine how RF redirection and load distribution are affected by upper extremity kinematic changes associated with seat position adjustment during a WCP task. Dynamic simulations using an experiment-based multi-link inverse dynamics model were used to generate solutions for redistributing UE mechanical load in different seating positions without decrements in WCP task performance. Experimental RF and kinematic data were collected for one subject propelling at a self-selected speed and used as input into the model. Shoulder/axle distance, wrist angular position, and RF direction were systematically modified to simulate how the mechanical demand imposed on the upper extremity (elbow and shoulder net joint moments (NJMs) and net joint forces) may vary. Load distribution depended on UE orientation relative to the wheel. At peak force, lower shoulder/axle distances and more anterior wrist positions on the pushrim allowed for more extended elbow positions and reduced total NJM load. Simulation results incorporating subject-specific data may provide mechanically based information to guide clinical interventions that aim to maintain WCP performance and redistribute load by modifying RF direction, seat configuration and hand/rim interaction. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  11. [Reconstruction of severe contracture of the first web space and wrist by incorporating pedicled retrograde flap of forearm transplantation].

    PubMed

    Chen, Jianchong; Wu, Zuhuang; Zhu, Jianxian; Huang, Yongxin; Xie, Baogen

    2011-10-01

    To summarize the therapeutic effectiveness of incorporating pedicled retrograde flap of forearm transplantation for reconstructing severe contracture of the first web space and wrist. Between November 2005 and February 2010, 26 patients with severe contracture of the first web and wrist were treated. There were 18 males and 8 females with an average age of 27 years (range, 12-45 years). The locations were the right sides in 15 cases and the left sides in 11 cases. The injury reason included hot water scald in 7 cases, explosion hurt in 5 cases, traffic accident in 3 cases, hot pressing in 5 cases, and flame burns in 6 cases. The duration of scar contracture ranged from 6 to 26 months with an average of 11 months. According to the evaluation standard by GU Yudong et al., all had severe contracture of the first web space, and concomitant injuries included adduction deformity thumb, limitation of the thumb extension and opposition function, and carpometacarpal flexion joint deformity. After scar contracture was released, the defect size ranged from 5.8 cm x 4.5 cm to 11.3 cm x 7.2 cm, which were repaired by the incorporating pedicled retrograde flap of forearm of 6.5 cm x 5.0 cm to 12.5 cm x 8.0 cm at size. The donor sites were directly sutured or repaired with skin graft. Blister and partial necrosis occurred at the distal end of the flaps in 2 cases, which were cured after dressing change. The other flaps survived and wounds healed by first intention. Incisions at donor sites healed by first intention. Twenty-six patients were followed up 6 to 24 months (mean, 15 months). The patients had functional recovery in thumb adduction and opposition at different degrees. At 6 months after operation, according to the Swanson et al. AMA system for total thumb activity, the total thumb function was improved significantly, and according to Jensen et al. measurement, the width and angle of the first web space were significantly increased, all showing significant differences (P < 0.05). Incorporating pedicled retrograde flap of forearm transplantation for repairing severe contracture of the first web space and wrist could augment the first web space and improve the wrist flexible function.

  12. 4-corner arthrodesis and proximal row carpectomy: a biomechanical comparison of wrist motion and tendon forces.

    PubMed

    Debottis, Daniel P; Werner, Frederick W; Sutton, Levi G; Harley, Brian J

    2013-05-01

    Controversy exists as to whether a proximal row carpectomy (PRC) is a better procedure than scaphoid excision with 4-corner arthrodesis for preserving motion in the painful posttraumatic arthritic wrist. The purpose of this study was to determine how the kinematics and tendon forces of the wrist are altered after PRC and 4-corner arthrodesis. We tested 6 fresh cadaver forearms for the extremes of wrist motion and then used a wrist simulator to move them through 4 cyclic dynamic wrist motions, during which time we continuously recorded the tendon forces. We repeated the extremes of wrist motion measurements and the dynamic motions after scaphoid excision with 4-corner arthrodesis, and then again after PRC. We analyzed extremes of wrist motion and the peak tendon forces required for each dynamic motion using a repeated measures analysis of variance. Wrist extremes of motion significantly decreased after both the PRC and 4-corner arthrodesis compared with the intact wrist. Wrist flexion decreased on average 13° after 4-corner arthrodesis and 12° after PRC. Extension decreased 20° after 4-corner arthrodesis and 12° after PRC. Four-corner arthrodesis significantly decreased wrist ulnar deviation from the intact wrist. Four-corner arthrodesis allowed more radial deviation but less ulnar deviation than the PRC. The average peak tendon force was significantly greater after 4-corner arthrodesis than after PRC for the extensor carpi ulnaris during wrist flexion-extension, circumduction, and dart throw motions. The peak forces were significantly greater after 4-corner arthrodesis than in the intact wrist for the extensor carpi ulnaris during the dart throw motion and for the flexor carpi ulnaris during the circumduction motion. The peak extensor carpi radialis brevis force after PRC was significantly less than in the intact wrist. The measured wrist extremes of motion decreased after both 4-corner arthrodesis and PRC. Larger peak tendon forces were required to achieve identical wrist motions with the 4-corner arthrodesis compared with the intact wrist. We observed smaller forces for the PRC. These results may help explain why PRC shows early clinical improvement, yet may lead to degenerative arthritis. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  13. Structural and Treatment Analyses of Safe and At-Risk Behaviors and Postures Performed by Pharmacy Employees

    ERIC Educational Resources Information Center

    Fante, Rhiannon; Gravina, Nicole; Betz, Alison; Austin, John

    2010-01-01

    This study employed structural and treatment analyses to determine factors that contributed to wrist posture safety in a small pharmacy. The pharmacy was located on a university campus and participants were three female pharmacy technicians. These particular employees had experienced various repetitive-motion injuries that resulted in a total of…

  14. MRI evidence of persistent joint inflammation and progressive joint damage despite clinical remission during treatment of early rheumatoid arthritis.

    PubMed

    Forslind, K; Svensson, B

    2016-01-01

    To determine the value of magnetic resonance imaging (MRI) of bones and joints in patients with recent-onset rheumatoid arthritis (RA) treated for 2 years from diagnosis with disease-modifying anti-rheumatic drugs (DMARDs) and glucocorticoids. Thirteen patients with early RA were treated according to clinical practice and followed with MRI, radiographs, and Disease Activity Score calculated on 28 joints (DAS28) at inclusion (baseline) and after 1, 4, 7, 13, and 25 months. MRI of the dominant wrist and metacarpophalangeal (MCP) joints were assessed for synovitis, bone oedema, and erosions using the RA MRI Score (RAMRIS) and for tenosynovitis by an MRI tenosynovitis scoring method. Radiographs were assessed by the van der Heijde modified Sharp score (SHS). Clinical remission was defined by a DAS28 < 2.6. MRI at baseline detected inflammation in joints and tendons in all patients as well as erosions in 10 out of 13 patients. Over time, the erosion score increased while the synovitis and tenosynovitis scores remained almost unchanged. Bone oedema strongly correlated with synovitis. Synovitis and tenosynovitis correlated well with the erosion score at baseline but not thereafter. The MRI changes showed that joint damage started early and continued in the presence of persistent synovial and tenosynovial inflammation. The observations made in this small study suggest that the treatment goal of 'clinical remission' should be supplemented by a 'joint remission' goal. To this end, MRI is an appropriate tool. Further studies are needed to evaluate the optimal use of MRI in early RA.

  15. Monitoring Human Performance During Suited Operations: A Technology Feasibility Study Using EMU Gloves

    NASA Technical Reports Server (NTRS)

    Bekdash, Omar; Norcross, Jason; McFarland, Shane

    2015-01-01

    Mobility tracking of human subjects while conducting suited operations still remains focused on the external movement of the suit and little is known about the human movement within it. For this study, accelerometers and bend sensitive resistors were integrated into a custom carrier glove to quantify range of motion and dexterity from within the pressurized glove environment as a first stage feasibility study of sensor hardware, integration, and reporting capabilities. Sensors were also placed on the exterior of the pressurized glove to determine if it was possible to compare a glove joint angle to the anatomical joint angle of the subject during tasks. Quantifying human movement within the suit was feasible, with accelerometers clearly detecting movements in the wrist and reporting expected joint angles at maximum flexion or extension postures with repeatability of plus or minus 5 degrees between trials. Bend sensors placed on the proximal interphalangeal and distal interphalangeal joints performed less well. It was not possible to accurately determine the actual joint angle using these bend sensors, but these sensors could be used to determine when the joint was flexed to its maximum and provide a general range of mobility needed to complete a task. Further work includes additional testing with accelerometers and the possible inclusion of hardware such as magnetometers or gyroscopes to more precisely locate the joint in 3D space. We hope to eventually expand beyond the hand and glove and develop a more comprehensive suit sensor suite to characterize motion across more joints (knee, elbow, shoulder, etc.) and fully monitor the human body operating within the suit environment.

  16. Accelerometer output and its association with energy expenditure during manual wheelchair propulsion.

    PubMed

    Learmonth, Y C; Kinnett-Hopkins, D; Rice, I M; Dysterheft, J L; Motl, R W

    2016-02-01

    This is an experimental design. This study examined the association between rates of energy expenditure (that is, oxygen consumption (VO2)) and accelerometer counts (that is, vector magnitude (VM)) across a range of speeds during manual wheelchair propulsion on a motor-driven treadmill. Such an association allows for the generation of cutoff points for quantifying the time spent in moderate-to-vigorous physical activity (MVPA) during manual wheelchair propulsion. The study was conducted in the University Laboratory. Twenty-four manual wheelchair users completed a 6-min period of seated rest and three 6-min periods of manual wheelchair propulsion on a motor-driven wheelchair treadmill. The 6-min periods of wheelchair propulsion corresponded with three treadmill speeds (1.5, 3.0 and 4.5 mph) that elicited a range of physical activity intensities. Participants wore a portable metabolic unit and accelerometers on both wrists. Primary outcome measures included steady-state VO2 and VM, and the strength of association between VO2 and VM was based on the multiple correlation and squared multiple correlation coefficients from linear regression analyses. Strong linear associations were established between VO2 and VM for the left (R=0.93±0.44; R2=0.87±0.19), right (R=0.95±0.37; R2=0.90±0.14) and combined (R=0.94±0.38; R2=0.88±0.15) accelerometers. The linear relationship between VO2 and VM for the left, right and combined wrists yielded cutoff points for MVPA of 3659 ±1302, 3630±1403 and 3644±1339 counts min(-1), respectively. We provide cutoff points based on the linear association between energy expenditure and accelerometer counts for estimating time spent in MVPA during manual wheelchair propulsion using wrist-worn accelerometry. The similarity across wrist location permits flexibility in selecting a location for wrist accelerometry placement.

  17. Ulnar neuropathy at or distal to the wrist: traumatic versus cumulative stress cases.

    PubMed

    Chiodo, Anthony; Chadd, Edmund

    2007-04-01

    To identify clinical and electromyographic characteristics of ulnar neuropathy at or below the wrist, comparing those caused by unitary trauma with those caused by suspected cumulative stress. Retrospective case series. University hospital electromyography laboratory. Patients with electrodiagnostic evidence of an ulnar neuropathy at or distal to the wrist over a 3-year period. Forty-seven hands from 42 patients (age range, 20-80y; mean, 52y) were identified and evaluated in this study. Record review of clinical history, physical examination, electromyography, and treatment. Etiology of injury, physical signs and symptoms, and electromyographic testing results. Ulnar neuropathy at or distal to the wrist is commonly mischaracterized because of other mononeuropathies in the upper extremity and because of peripheral polyneuropathy. Ulnar neuropathy because of cumulative stress presents typically with sensory symptoms (63%) and a normal examination (71%), whereas trauma cases present with motor with or without sensory symptoms (92%) with motor abnormalities (92%) confirmed on examination. Traumatic cases are characterized by electromyography by decreased sensory and motor-evoked amplitudes, prolonged motor distal latencies, and abnormal needle examination. The amplitude changes are noted comparing with laboratory norms and comparing side to side. No characteristic pattern of abnormalities on electromyography is noted in the cumulative stress cases. Patients with no motor symptoms, regardless of etiology, are more apt to have sensory distal latency prolongation, whereas those with motor symptoms have motor amplitude and needle examination abnormalities. Traumatic ulnar neuropathy at or distal to the wrist is characterized by motor symptoms and sensory and motor axonal loss by electromyography, whereas cumulative stress cases have sensory symptoms and electromyographic findings that are highly variable and noncharacteristic. Patients with no motor symptoms are more apt to show sensory distal latency abnormalities on electromyography, whereas those with motor symptoms show motor-evoked amplitude and needle electromyography abnormalities.

  18. Three-dimensional-printed upper limb prosthesis for a child with traumatic amputation of right wrist: A case report.

    PubMed

    Xu, Guisheng; Gao, Liang; Tao, Ke; Wan, Shengxiang; Lin, Yuning; Xiong, Ao; Kang, Bin; Zeng, Hui

    2017-12-01

    For traumatic upper limb amputees, the prohibitive cost of a custom-made prosthesis brings an insufferable financial burden for their families in developing countries. Three-dimensional (3D) printing allows for creating affordable, lightweight, customized, and well-fitting prosthesis, especially for the growing children. We presented a case of an 8-year-old boy, who suffered a traumatic right wrist amputation as result of a mincing machine accident. The patient was immediately sent to the emergency orthopedics department after the accident. He was diagnosed as severed mangled limb crash injury at the level of the right wrist with a Mangled Extremity Severity Score of 8. A wrist disarticulation was performed and a 3D-printed prosthetic hand was designed and manufactured for this child. A personalized prosthetic rehabilitation training was applied after the prosthesis installation at 6 months postoperatively. The function of the prosthesis was evaluated at 1-month and 3-month follow-up using the Children Amputee Prosthetics Projects (CAPP) score and the University Of New Brunswick Test Of Prosthetic Function for Unilateral Amputees (UNB test). The materials cost <20 dollars. The printing took <8 hours and the component assembling was completed within 20 minutes. During the 3-month follow-up, the child's parents were satisfied with the prosthesis and the UNB test showed the significantly improved function of the prosthesis. This novel 3D-printed upper limb prosthesis in a child with the traumatic wrist amputation might serve as a practical and affordable alternative for children in developing countries and those lacking access to health care providers. A personalized prosthetic rehabilitation needs to be undertaken and more clinical studies are warranted to validate the potential superiority of similar 3D-printed prostheses. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  19. Hand/Wrist Disorders among Sign Language Communicators.

    ERIC Educational Resources Information Center

    Smith, Susan M.; Kress, Tyler A.; Hart, William M.

    2000-01-01

    A study assessed the frequency of self-reported hand/wrist problems among 184 sign-language communicators. Fifty-nine percent reported experiencing hand/wrist problems, 26 percent reported experiencing hand/wrist problems severe enough to limit their ability to work, and 18 percent reported a medical diagnosis of wrist tendinitis, carpal tunnel…

  20. Smartphone photography utilized to measure wrist range of motion.

    PubMed

    Wagner, Eric R; Conti Mica, Megan; Shin, Alexander Y

    2018-02-01

    The purpose was to determine if smartphone photography is a reliable tool in measuring wrist movement. Smartphones were used to take digital photos of both wrists in 32 normal participants (64 wrists) at extremes of wrist motion. The smartphone measurements were compared with clinical goniometry measurements. There was a very high correlation between the clinical goniometry and smartphone measurements, as the concordance coefficients were high for radial deviation, ulnar deviation, wrist extension and wrist flexion. The Pearson coefficients also demonstrated the high precision of the smartphone measurements. The Bland-Altman plots demonstrated 29-31 of 32 smartphone measurements were within the 95% confidence interval of the clinical measurements for all positions of the wrists. There was high reliability between the photography taken by the volunteer and researcher, as well as high inter-observer reliability. Smartphone digital photography is a reliable and accurate tool for measuring wrist range of motion. II.

  1. Effects of grip force on median nerve deformation at different wrist angles

    PubMed Central

    Nakashima, Hiroki; Muraki, Satoshi

    2016-01-01

    The present study investigated the effects of grip on changes in the median nerve cross-sectional area (MNCSA) and median nerve diameter in the radial-ulnar direction (D1) and dorsal-palmar direction (D2) at three wrist angles. Twenty-nine healthy participants (19 men [mean age, 24.2 ± 1.6 years]; 10 women [mean age, 24.0 ± 1.6 years]) were recruited. The median nerve was examined at the proximal carpal tunnel region in three grip conditions, namely finger relaxation, unclenched fist, and clenched fist. Ultrasound examinations were performed in the neutral wrist position (0°), at 30°wrist flexion, and at 30°wrist extension for both wrists. The grip condition and wrist angle showed significant main effects (p < 0.01) on the changes in the MNCSA, D1, and D2. Furthermore, significant interactions (p < 0.01) were found between the grip condition and wrist angle for the MNCSA, D1, and D2. In the neutral wrist position (0°), significant reductions in the MNCSA, D1, and D2 were observed when finger relaxation changed to unclenched fist and clenched fist conditions. Clenched fist condition caused the highest deformations in the median nerve measurements (MNCSA, approximately −25%; D1, −13%; D2, −12%). The MNCSA was significantly lower at 30°wrist flexion and 30°wrist extension than in the neutral wrist position (0°) at unclenched fist and clenched fist conditions. Notably, clenched fist condition at 30°wrist flexion showed the highest reduction of the MNCSA (−29%). In addition, 30°wrist flexion resulted in a lower D1 at clenched fist condition. In contrast, 30°wrist extension resulted in a lower D2 at both unclenched fist and clenched fist conditions. Our results suggest that unclenched fist and clenched fist conditions cause reductions in the MNCSA, D1, and D2. More importantly, unclenched fist and clenched fist conditions at 30°wrist flexion and 30°wrist extension can lead to further deformation of the median nerve. PMID:27688983

  2. Tenosynovitis US scoring systems follow synovitis and clinical scoring systems in RA and are responsive to change after biologic therapy.

    PubMed

    Vlad, Violeta; Berghea, Florian; Micu, Mihaela; Varzaru, Luminita; Bojinca, Mihai; Milicescu, Mihaela; Ionescu, Ruxandra; Naredo, Esperanza

    2015-09-01

    To investigate by ultrasonography (US) in a cohort of active RA patients starting biologic therapy the responsiveness of tenosynovitis of wrist and hands compared to the responsiveness of synovitis in a 6 month period follow-up, to compare the responsiveness of finger flexor tenosynovitis with the responsiveness of wrist extensor tenosynovitis and to describe the subclinical synovitis and tenosynovitis in RA patients in clinical remission. Fifty seven patients with active RA starting biologic therapy were included. Clinical, laboratory, and US evaluations were performed at baseline, 1, and 6 months. US evaluation included wrist and MCPs 2-5 joints, bilaterally for synovitis and extensor tendons compartments 2, 4, and 6 and finger flexors 2-5 for tenosynovitis. Eighteen US scores based on semiquantitative or binary grades were calculated at each visit. Responsiveness of synovitis and tenosynovitis scores was calculated using the standardized response mean (SRM). The responsiveness of US tenosynovitis was lower comparing with the responsiveness of US synovitis but both showed large effect of therapy. Furthermore, tenosynovitis responsiveness was similar to CRP responsiveness (SRM -0.90). Finger flexors tenosynovitis showed a higher responsiveness than extensor tenosynovitis on GS (-0.94 compared to -0.63) and a lower SRM on PD (-0.56 compared to -0.85). Tenosynovitis scores remission was overlapping clinical remission according to CDAI and SDAI in 100% of cases. Overall there was less subclinical tenosynovitis than subclinical synovitis at final visit according to clinical activity indices. Tenosynovitis US scoring in RA may be as good as synovitis scoring for characterization of disease activity and responsiveness.

  3. Distal radius fractures and the volar lunate facet fragment: Kirschner wire fixation in addition to volar-locked plating.

    PubMed

    Moore, Amy M; Dennison, David G

    2014-06-01

    The volar lunate facet fragment of a distal radius fracture may not be stabilized with volar-locked plating alone due to the small size and distal location of the fragment. Identification and stabilization of this small fragment is critical as unstable fixation may result in radiocarpal and radioulnar joint subluxation. The addition of spring wire fixation with volar plating can provide stable internal fixation of this critical fracture fragment. A retrospective review (2006-2011) identified nine patients with distal radius fractures with an associated volar lunate facet fragment that were treated with volar-locked plating and spring wire fixation of the volar lunate facet fragment. Radiographic indices, range of motion, grip strength, and postoperative Patient-related wrist evaluation (PRWE) scores were obtained to assess pain and function. All distal radius fractures healed, and the volar lunate facet fragment reduction was maintained. The mean follow-up was 54 weeks. Mean active range of motion was 46° wrist flexion, 51° wrist extension, 80° pronation, and 68° supination. The mean grip strength was 21 Kg, achieving 66 % of the uninjured limb. The average PRWE score was 17. No patient required removal of hardware or had evidence of tendon irritation. The addition of spring wire fixation to volar-locked plating provided stable fixation of the volar lunate facet fragment of distal radius fractures without complication. This technique addresses a limitation of volar-locked plating to control the small volar lunate facet fragment in distal radius fractures otherwise amenable to volar plating. A retrospective case series, Level IV.

  4. Real-time simultaneous and proportional myoelectric control using intramuscular EMG

    PubMed Central

    Kuiken, Todd A; Hargrove, Levi J

    2014-01-01

    Objective Myoelectric prostheses use electromyographic (EMG) signals to control movement of prosthetic joints. Clinically available myoelectric control strategies do not allow simultaneous movement of multiple degrees of freedom (DOFs); however, the use of implantable devices that record intramuscular EMG signals could overcome this constraint. The objective of this study was to evaluate the real-time simultaneous control of three DOFs (wrist rotation, wrist flexion/extension, and hand open/close) using intramuscular EMG. Approach We evaluated task performance of five able-bodied subjects in a virtual environment using two control strategies with fine-wire EMG: (i) parallel dual-site differential control, which enabled simultaneous control of three DOFs and (ii) pattern recognition control, which required sequential control of DOFs. Main Results Over the course of the experiment, subjects using parallel dual-site control demonstrated increased use of simultaneous control and improved performance in a Fitts' Law test. By the end of the experiment, performance using parallel dual-site control was significantly better (up to a 25% increase in throughput) than when using sequential pattern recognition control for tasks requiring multiple DOFs. The learning trends with parallel dual-site control suggested that further improvements in performance metrics were possible. Subjects occasionally experienced difficulty in performing isolated single-DOF movements with parallel dual-site control but were able to accomplish related Fitts' Law tasks with high levels of path efficiency. Significance These results suggest that intramuscular EMG, used in a parallel dual-site configuration, can provide simultaneous control of a multi-DOF prosthetic wrist and hand and may outperform current methods that enforce sequential control. PMID:25394366

  5. Real-time simultaneous and proportional myoelectric control using intramuscular EMG

    NASA Astrophysics Data System (ADS)

    Smith, Lauren H.; Kuiken, Todd A.; Hargrove, Levi J.

    2014-12-01

    Objective. Myoelectric prostheses use electromyographic (EMG) signals to control movement of prosthetic joints. Clinically available myoelectric control strategies do not allow simultaneous movement of multiple degrees of freedom (DOFs); however, the use of implantable devices that record intramuscular EMG signals could overcome this constraint. The objective of this study was to evaluate the real-time simultaneous control of three DOFs (wrist rotation, wrist flexion/extension, and hand open/close) using intramuscular EMG. Approach. We evaluated task performance of five able-bodied subjects in a virtual environment using two control strategies with fine-wire EMG: (i) parallel dual-site differential control, which enabled simultaneous control of three DOFs and (ii) pattern recognition control, which required sequential control of DOFs. Main results. Over the course of the experiment, subjects using parallel dual-site control demonstrated increased use of simultaneous control and improved performance in a Fitts’ Law test. By the end of the experiment, performance using parallel dual-site control was significantly better (up to a 25% increase in throughput) than when using sequential pattern recognition control for tasks requiring multiple DOFs. The learning trends with parallel dual-site control suggested that further improvements in performance metrics were possible. Subjects occasionally experienced difficulty in performing isolated single-DOF movements with parallel dual-site control but were able to accomplish related Fitts’ Law tasks with high levels of path efficiency. Significance. These results suggest that intramuscular EMG, used in a parallel dual-site configuration, can provide simultaneous control of a multi-DOF prosthetic wrist and hand and may outperform current methods that enforce sequential control.

  6. System Characterization of MAHI EXO-II: A Robotic Exoskeleton for Upper Extremity Rehabilitation

    PubMed Central

    French, James A.; Rose, Chad G.; O'Malley, Marcia K.

    2015-01-01

    This paper presents the performance characterization of the MAHI Exo-II, an upper extremity exoskeleton for stroke and spinal cord injury (SCI) rehabilitation, as a means to validate its clinical implementation and to provide depth to the literature on the performance characteristics of upper extremity exoskeletons. Individuals with disabilities arising from stroke and SCI need rehabilitation of the elbow, forearm, and wrist to restore the ability to independently perform activities of daily living (ADL). Robotic rehabilitation has been proposed to address the need for high intensity, long duration therapy and has shown promising results for upper limb proximal joints. However, upper limb distal joints have historically not benefitted from the same focus. The MAHI Exo-II, designed to address this shortcoming, has undergone a static and dynamic performance characterization, which shows that it exhibits the requisite qualities for a rehabilitation robot and is comparable to other state-of-the-art designs. PMID:25984380

  7. System Characterization of MAHI EXO-II: A Robotic Exoskeleton for Upper Extremity Rehabilitation.

    PubMed

    French, James A; Rose, Chad G; O'Malley, Marcia K

    2014-10-01

    This paper presents the performance characterization of the MAHI Exo-II, an upper extremity exoskeleton for stroke and spinal cord injury (SCI) rehabilitation, as a means to validate its clinical implementation and to provide depth to the literature on the performance characteristics of upper extremity exoskeletons. Individuals with disabilities arising from stroke and SCI need rehabilitation of the elbow, forearm, and wrist to restore the ability to independently perform activities of daily living (ADL). Robotic rehabilitation has been proposed to address the need for high intensity, long duration therapy and has shown promising results for upper limb proximal joints. However, upper limb distal joints have historically not benefitted from the same focus. The MAHI Exo-II, designed to address this shortcoming, has undergone a static and dynamic performance characterization, which shows that it exhibits the requisite qualities for a rehabilitation robot and is comparable to other state-of-the-art designs.

  8. An improved arterial pulsation measurement system based on optical triangulation and its application in the traditional Chinese medicine

    NASA Astrophysics Data System (ADS)

    Wu, Jih-Huah; Lee, Wen-Li; Lee, Yun-Parn; Lin, Ching-Huang; Chiou, Ji-Yi; Tai, Chuan-Fu; Jiang, Joe-Air

    2011-08-01

    An improved arterial pulsation measurement (APM) system that uses three LED light sources and a CCD image sensor to measure pulse waveforms of artery is presented. The relative variations of the pulses at three measurement points near wrist joints can be determined by the APM system simultaneously. The height of the arterial pulsations measured by the APM system achieves a resolution of better than 2 μm. These pulsations contain useful information that can be used as diagnostic references in the traditional Chinese medicine (TCM) in the future.

  9. Wrist Fractures

    MedlinePlus

    ... Wrist Fractures Find a hand surgeon near you. Videos Wrist Fractures Close Popup Figures Figure 1 - Wrist ... or "in." Also, avoid using media types like "video," "article," and "picture." Tip 4: Your results can ...

  10. Subject-Specific Carpal Ligament Elongation in Extreme Positions, Grip, and the Dart Thrower's Motion

    PubMed Central

    Rainbow, Michael J.; Kamal, Robin N.; Moore, Douglas C.; Akelman, Edward; Wolfe, Scott W.; Crisco, Joseph J.

    2015-01-01

    This study examined whether the radiocarpal and dorsal capsular ligaments limit end-range wrist motion or remain strained during midrange wrist motion. Fibers of these ligaments were modeled in the wrists of 12 subjects over multiple wrist positions that reflect high demand tasks and the dart thrower's motion. We found that many of the volar and dorsal ligaments were within 5% of their maximum length throughout the range of wrist motion. Our finding of wrist ligament recruitment during midrange and end-range wrist motion helps to explain the complex but remarkably similar intersubject patterns of carpal motion. PMID:26367853

  11. Scoring ultrasound synovitis in rheumatoid arthritis: a EULAR-OMERACT ultrasound taskforce-Part 2: reliability and application to multiple joints of a standardised consensus-based scoring system

    PubMed Central

    Terslev, Lene; Naredo, Esperanza; Aegerter, Philippe; Wakefield, Richard J; Backhaus, Marina; Balint, Peter; Bruyn, George A W; Iagnocco, Annamaria; Jousse-Joulin, Sandrine; Schmidt, Wolfgang A; Szkudlarek, Marcin; Conaghan, Philip G; Filippucci, Emilio

    2017-01-01

    Objectives To test the reliability of new ultrasound (US) definitions and quantification of synovial hypertrophy (SH) and power Doppler (PD) signal, separately and in combination, in a range of joints in patients with rheumatoid arthritis (RA) using the European League Against Rheumatisms–Outcomes Measures in Rheumatology (EULAR-OMERACT) combined score for PD and SH. Methods A stepwise approach was used: (1) scoring static images of metacarpophalangeal (MCP) joints in a web-based exercise and subsequently when scanning patients; (2) scoring static images of wrist, proximal interphalangeal joints, knee and metatarsophalangeal joints in a web-based exercise and subsequently when scanning patients using different acquisitions (standardised vs usual practice). For reliability, kappa coefficients (κ) were used. Results Scoring MCP joints in static images showed substantial intraobserver variability but good to excellent interobserver reliability. In patients, intraobserver reliability was the same for the two acquisition methods. Interobserver reliability for SH (κ=0.87) and PD (κ=0.79) and the EULAR-OMERACT combined score (κ=0.86) were better when using a ‘standardised’ scan. For the other joints, the intraobserver reliability was excellent in static images for all scores (κ=0.8–0.97) and the interobserver reliability marginally lower. When using standardised scanning in patients, the intraobserver was good (κ=0.64 for SH and the EULAR-OMERACT combined score, 0.66 for PD) and the interobserver reliability was also good especially for PD (κ range=0.41–0.92). Conclusion The EULAR-OMERACT score demonstrated moderate-good reliability in MCP joints using a standardised scan and is equally applicable in non-MCP joints. This scoring system should underpin improved reliability and consequently the responsiveness of US in RA clinical trials. PMID:28948984

  12. Low-Friction, High-Stiffness Joint for Uniaxial Load Cell

    NASA Technical Reports Server (NTRS)

    Lewis, James L.; Le, Thang; Carroll, Monty B.

    2007-01-01

    A universal-joint assembly has been devised for transferring axial tension or compression to a load cell. To maximize measurement accuracy, the assembly is required to minimize any moments and non-axial forces on the load cell and to exhibit little or no hysteresis. The requirement to minimize hysteresis translates to a requirement to maximize axial stiffness (including minimizing backlash) and a simultaneous requirement to minimize friction. In practice, these are competing requirements, encountered repeatedly in efforts to design universal joints. Often, universal-joint designs represent compromises between these requirements. The improved universal-joint assembly contains two universal joints, each containing two adjustable pairs of angular-contact ball bearings. One might be tempted to ask why one could not use simple ball-and-socket joints rather than something as complex as universal joints containing adjustable pairs of angularcontact ball bearings. The answer is that ball-and-socket joints do not offer sufficient latitude to trade stiffness versus friction: the inevitable result of an attempt to make such a trade in a ball-and-socket joint is either too much backlash or too much friction. The universal joints are located at opposite ends of an axial subassembly that contains the load cell. The axial subassembly includes an axial shaft, an axial housing, and a fifth adjustable pair of angular-contact ball bearings that allows rotation of the axial housing relative to the shaft. The preload on each pair of angular-contact ball bearings can be adjusted to obtain the required stiffness with minimal friction, tailored for a specific application. The universal joint at each end affords two degrees of freedom, allowing only axial force to reach the load cell regardless of application of moments and non-axial forces. The rotational joint on the axial subassembly affords a fifth degree of freedom, preventing application of a torsion load to the load cell.

  13. Update on the evaluation of wrist pain.

    PubMed

    Nichols, Chris M; Cheng, Christine

    2006-01-01

    Wrist pain is a common presenting complaint in patients both for the hand specialist and the primary care physician. Knowledge of wrist anatomy and a thorough and systematic wrist examination remain the mainstays of evaluation. Radiologic as well as arthroscopic technology and techniques continue to evolve and provide useful adjuncts to wrist evaluation that expand our diagnostic and therapeutic capabilities.

  14. Management of the failed biaxial wrist replacement.

    PubMed

    Talwalkar, S C; Hayton, M J; Trail, I A; Stanley, J K

    2005-06-01

    Nine cases of failed biaxial wrist replacement underwent revision surgery and subsequent clinical and radiographic assessment at a mean follow-up of 28 months. Clinical assessment included the hospital for special surgery (HSS) and activities of daily living scoring systems. Five patients had a revision biaxial wrist replacement, three had wrist fusions and two underwent an excision arthroplasty. The mean HSS score was 73 for the revision biaxial replacements, 63 for the wrist fusions and 92 for the excision arthroplasties. The mean activities for daily living score was 16 for the revision biaxial replacements, 14 for the wrist fusion and 20 for the excision arthroplasties. Despite the experience of implant failure, six patients would still choose a primary wrist replacement again. All patients in this small series appear to have had good clinical outcomes. Revision to another wrist replacement appears no worse than a wrist fusion in the short term and patients value the preservation of movement that an implant offers.

  15. A New Wrist Clinical Evaluation Score.

    PubMed

    Herzberg, Guillaume; Burnier, Marion; Nakamura, Toshiyasu

    2018-04-01

    Background  The number of available wrist scoring systems is limited; some of them do not include forearm rotation criteria. Purpose  To describe a new electronic wrist clinical score and to present a new patient's generated wrist evaluation criterion, the subjective wrist value (SWV). Materials and Methods  A new electronic wrist clinical score, the Lyon wrist score (LWS) including wrist VAS pain and function, active range of motion and strength was built into an excel file. VAS flexion-extension pain and function were evaluated independently from pronation-supination pain and function. A new patient's generated wrist evaluation criterion, SWV was described. Results  The LWS is available in two versions, standard and full (the latter including forearm rotation strength). Both standard and full LWS are displayed into an automatically generated diamond-shaped graph providing a comprehensive visual display of the clinical status of most osteoarticular wrist disorders. The graph also includes SWV. The LWS, combined with SWV into a graph that may be directly exported to a PowerPoint presentation, provide a new practical and comprehensive tool for following/comparing wrist osteoarticular clinical status/outcomes. Both standard and full LWS charts are available in colored versions on a related website for free download. Conclusion  A comprehensive updated electronic display of osteoarticular wrist clinical status including forearm rotation criteria is provided and displayed into a graph which may be exported as such into a PowerPoint presentation for clinical analysis/comparisons. Level of Evidence  Level II.

  16. Young Women's Knowledge and Beliefs about Osteoporosis: Results from a Cross-Sectional Survey of College Females

    ERIC Educational Resources Information Center

    Kasper, Mark J.; Garber, Michele; Walsdorf, Kristie

    2007-01-01

    Background: About 40% of White American women over age 50 experience osteoporosis-related fracture of the hip, spine, or wrist during their lives. Purpose: The purpose of this study was to determine the level of osteoporosis knowledge and beliefs among young women. Methods: University women (n=302) completed a self-administered osteoporosis risk…

  17. The effects of rear-wheel camber on the kinematics of upper extremity during wheelchair propulsion

    PubMed Central

    2012-01-01

    Background The rear-wheel camber, defined as the inclination of the rear wheels, is usually used in wheelchair sports, but it is becoming increasingly employed in daily propulsion. Although the rear-wheel camber can increase stability, it alters physiological performance during propulsion. The purpose of the study is to investigate the effects of rear-wheel cambers on temporal-spatial parameters, joint angles, and propulsion patterns. Methods Twelve inexperienced subjects (22.3±1.6 yr) participated in the study. None had musculoskeletal disorders in their upper extremities. An eight-camera motion capture system was used to collect the three-dimensional trajectory data of markers attached to the wheelchair-user system during propulsion. All participants propelled the same wheelchair, which had an instrumented wheel with cambers of 0°, 9°, and 15°, respectively, at an average velocity of 1 m/s. Results The results show that the rear-wheel camber significantly affects the average acceleration, maximum end angle, trunk movement, elbow joint movement, wrist joint movement, and propulsion pattern. The effects are especially significant between 0° and 15°. For a 15° camber, the average acceleration and joint peak angles significantly increased (p < 0.01). A single loop pattern (SLOP) was adopted by most of the subjects. Conclusions The rear-wheel camber affects propulsion patterns and joint range of motion. When choosing a wheelchair with camber adjustment, the increase of joint movements and the base of support should be taken into consideration. PMID:23173938

  18. The effects of rear-wheel camber on the kinematics of upper extremity during wheelchair propulsion.

    PubMed

    Tsai, Chung-Ying; Lin, Chien-Ju; Huang, Yueh-Chu; Lin, Po-Chou; Su, Fong-Chin

    2012-11-22

    The rear-wheel camber, defined as the inclination of the rear wheels, is usually used in wheelchair sports, but it is becoming increasingly employed in daily propulsion. Although the rear-wheel camber can increase stability, it alters physiological performance during propulsion. The purpose of the study is to investigate the effects of rear-wheel cambers on temporal-spatial parameters, joint angles, and propulsion patterns. Twelve inexperienced subjects (22.3±1.6 yr) participated in the study. None had musculoskeletal disorders in their upper extremities. An eight-camera motion capture system was used to collect the three-dimensional trajectory data of markers attached to the wheelchair-user system during propulsion. All participants propelled the same wheelchair, which had an instrumented wheel with cambers of 0°, 9°, and 15°, respectively, at an average velocity of 1 m/s. The results show that the rear-wheel camber significantly affects the average acceleration, maximum end angle, trunk movement, elbow joint movement, wrist joint movement, and propulsion pattern. The effects are especially significant between 0° and 15°. For a 15° camber, the average acceleration and joint peak angles significantly increased (p < 0.01). A single loop pattern (SLOP) was adopted by most of the subjects. The rear-wheel camber affects propulsion patterns and joint range of motion. When choosing a wheelchair with camber adjustment, the increase of joint movements and the base of support should be taken into consideration.

  19. Rheumatic manifestations associated with Chikungunya virus infection: A study of 307 patients with 32-month follow-up (RHUMATOCHIK study).

    PubMed

    Bouquillard, Eric; Fianu, Adrian; Bangil, Marianne; Charlette, Nathalie; Ribéra, Anne; Michault, Alain; Favier, François; Simon, Fabrice; Flipo, René-Marc

    2018-03-01

    In the wake of the Chikungunya epidemic which struck Reunion Island in 2005 and 2006, we conducted a prospective, multicentre study (RHUMATOCHIK) whose main objective was analyse the characteristics and progression of rheumatic manifestations in patients with post-Chikungunya joint pain. A cohort of 307 consecutively included patients underwent rheumatological examinations for pain secondary to Chikungunya virus infection. The long-term evaluation was conducted by telephone survey 1 and 2 years after the onset of the viral infection. At inclusion, mean age was 54 years (24-87) and 83.1% of the patients were female. Chronic joint pain was associated with synovitis in 64.2% of the patients, affecting primarily the wrists, the proximal interphalangeal joints of the fingers, and the ankles. Attempts to detect the viral genome in joint fluid (10 patients) and synovial tissue (6 patients) using the RT-PCR technique were repeatedly unsuccessful. With a mean follow-up of 32 months, joint pain persisted in 83.1% of the patients. Functional impairment, however, was moderate, with a HAQ score of 0.44±0.5. Chikungunya virus infection is frequently the cause of joint manifestations that can persist for several months, or even several years. In some cases, the clinical symptoms closely resemble those usually associated with rheumatoid arthritis. Further studies are necessary to improve the therapeutic management of these patients. Copyright © 2017 Société française de rhumatologie. Published by Elsevier SAS. All rights reserved.

  20. Negative Influence of Motor Impairments on Upper Limb Movement Patterns in Children with Unilateral Cerebral Palsy. A Statistical Parametric Mapping Study

    PubMed Central

    Simon-Martinez, Cristina; Jaspers, Ellen; Mailleux, Lisa; Desloovere, Kaat; Vanrenterghem, Jos; Ortibus, Els; Molenaers, Guy; Feys, Hilde; Klingels, Katrijn

    2017-01-01

    Upper limb three-dimensional movement analysis (UL-3DMA) offers a reliable and valid tool to evaluate movement patterns in children with unilateral cerebral palsy (uCP). However, it remains unknown to what extent the underlying motor impairments explain deviant movement patterns. Such understanding is key to develop efficient rehabilitation programs. Although UL-3DMA has been shown to be a useful tool to assess movement patterns, it results in a multitude of data, challenging the clinical interpretation and consequently its implementation. UL-3DMA reports are often reduced to summary metrics, such as average or peak values per joint. However, these metrics do not take into account the continuous nature of the data or the interdependency between UL joints, and do not provide phase-specific information of the movement pattern. Moreover, summary metrics may not be sensitive enough to estimate the impact of motor impairments. Recently, Statistical Parametric Mapping (SPM) was proposed to overcome these problems. We collected UL-3DMA of 60 children with uCP and 60 typically developing children during eight functional tasks and evaluated the impact of spasticity and muscle weakness on UL movement patterns. SPM vector field analysis was used to analyze movement patterns at the level of five joints (wrist, elbow, shoulder, scapula, and trunk). Children with uCP showed deviant movement patterns in all joints during a large percentage of the movement cycle. Spasticity and muscle weakness negatively impacted on UL movement patterns during all tasks, which resulted in increased wrist flexion, elbow pronation and flexion, increased shoulder external rotation, decreased shoulder elevation with a preference for movement in the frontal plane and increased trunk internal rotation. Scapular position was altered during movement initiation, although scapular movements were not affected by muscle weakness or spasticity. In conclusion, we identified pathological movement patterns in children with uCP and additionally mapped the negative impact of spasticity and muscle weakness on these movement patterns, providing useful insights that will contribute to treatment planning. Last, we also identified a subset of the most relevant tasks for studying UL movements in children with uCP, which will facilitate the interpretation of UL-3DMA data and undoubtedly contribute to its clinical implementation. PMID:29051729

  1. Comparability and feasibility of wrist- and hip-worn accelerometers in free-living adolescents.

    PubMed

    Scott, Joseph J; Rowlands, Alex V; Cliff, Dylan P; Morgan, Philip J; Plotnikoff, Ronald C; Lubans, David R

    2017-12-01

    To determine the comparability and feasibility of wrist- and hip-worn accelerometers among free-living adolescents. 89 adolescents (age=13-14years old) from eight secondary schools in New South Wales (NSW), Australia wore wrist-worn GENEActiv and hip-worn ActiGraph (GT3X+) accelerometers simultaneously for seven days and completed an accelerometry behavior questionnaire. Bivariate correlations between the wrist- and hip-worn out-put were used to determine concurrent validity. Paired samples t-test were used to compare minutes per day in moderate-to-vigorous physical activity (MVPA). Group means and paired sample t-tests were used to analyze participants' perceptions of the wrist- and hip-worn monitoring protocols to assist with determining the feasibility. Wrist-worn accelerometry compared favorably with the hip-worn in average activity (r=0.88, p<0.001) and MVPA (r=0.84 p<0.001, mean difference=3.54min/day, SD=12.37). The wrist-worn accelerometer had 50% fewer non-valid days (75 days, 12%) than the hip-worn accelerometer (n=152, 24.4%). Participants reported they liked to wear the device on the wrist (p<0.01), and that it was less uncomfortable (p=0.02) and less embarrassing to wear on the wrist (p<0.01). Furthermore, that they would be more willing to wear the device again on the wrist over the hip (p<0.01). Our findings reveal there is a strong linear relationship between wrist- and hip-worn accelerometer out-put among adolescents in free-living conditions. Adolescent compliance was significantly higher with wrist placement, with participants reporting that it was more comfortable and less embarrassing to wear on the wrist. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  2. Correlation between radiological parameters and patient-rated wrist dysfunction following fractures of the distal radius.

    PubMed

    Karnezis, I A; Panagiotopoulos, E; Tyllianakis, M; Megas, P; Lambiris, E

    2005-12-01

    The present study investigates the correlation between radiological parameters of wrist fractures and the clinical outcome expressed by objective clinical parameters and the level of patient-rated wrist dysfunction. Thirty consecutive cases of unstable distal radial fractures treated with closed reduction and percutaneous fixation were prospectively studied for a period of one year. The outcome parameters included objective clinical and radiological parameters and the previously described and validated patient-rated wrist evaluation (PRWE) score. Analysis showed that for unstable (AO classification types 23-A2, -A3, -C1 and -C2) fractures the fracture type affects the range of wrist palmarflexion (p=0.04) and that the presence of postoperative articular 'step-off' affects the range of wrist dorsiflexion and the patient-rated wrist function at the final time of the study (p<0.01 and p=0.02, respectively). It is also shown that permanent radial shortening and loss of the palmar angle were associated with prolonged wrist pain (p<0.01 and p=0.03, respectively). Our finding that residual articular incongruity correlates with persisting loss of wrist dorsiflexion and wrist dysfunction contradicts the view that loss of articular congruity is associated with late development of articular degeneration but not with early wrist dysfunction. Additionally, this study failed to show any association between the fracture type and the functional outcome as rated by the patients.

  3. [The Amsterdam wrist rules: the multicenter prospective derivation and external validation of a clinical decision rule for the use of radiography in acute wrist trauma].

    PubMed

    Walenkamp, Monique M J; Bentohami, Abdelali; Slaar, Annelie; Beerekamp, M S H Suzan; Maas, Mario; Jager, L C Cara; Sosef, Nico L; van Velde, Romuald; Ultee, Jan M; Steyerberg, Ewout W; Goslings, J C Carel; Schep, Niels W L

    2016-01-01

    Although only 39% of patients with wrist trauma have sustained a fracture, the majority of patients is routinely referred for radiography. The purpose of this study was to derive and externally validate a clinical decision rule that selects patients with acute wrist trauma in the Emergency Department (ED) for radiography. This multicenter prospective study consisted of three components: (1) derivation of a clinical prediction model for detecting wrist fractures in patients following wrist trauma; (2) external validation of this model; and (3) design of a clinical decision rule. The study was conducted in the EDs of five Dutch hospitals: one academic hospital (derivation cohort) and four regional hospitals (external validation cohort). We included all adult patients with acute wrist trauma. The main outcome was fracture of the wrist (distal radius, distal ulna or carpal bones) diagnosed on conventional X-rays. A total of 882 patients were analyzed; 487 in the derivation cohort and 395 in the validation cohort. We derived a clinical prediction model with eight variables: age; sex, swelling of the wrist; swelling of the anatomical snuffbox, visible deformation; distal radius tender to palpation; pain on radial deviation and painful axial compression of the thumb. The Area Under the Curve at external validation of this model was 0.81 (95% CI: 0.77-0.85). The sensitivity and specificity of the Amsterdam Wrist Rules (AWR) in the external validation cohort were 98% (95% CI: 95-99%) and 21% (95% CI: 15%-28). The negative predictive value was 90% (95% CI: 81-99%). The Amsterdam Wrist Rules is a clinical prediction rule with a high sensitivity and negative predictive value for fractures of the wrist. Although external validation showed low specificity and 100 % sensitivity could not be achieved, the Amsterdam Wrist Rules can provide physicians in the Emergency Department with a useful screening tool to select patients with acute wrist trauma for radiography. The upcoming implementation study will further reveal the impact of the Amsterdam Wrist Rules on the anticipated reduction of X-rays requested, missed fractures, Emergency Department waiting times and health care costs.

  4. Detection of physical activities using a physical activity monitor system for wheelchair users.

    PubMed

    Hiremath, Shivayogi V; Intille, Stephen S; Kelleher, Annmarie; Cooper, Rory A; Ding, Dan

    2015-01-01

    Availability of physical activity monitors for wheelchair users can potentially assist these individuals to track regular physical activity (PA), which in turn could lead to a healthier and more active lifestyle. Therefore, the aim of this study was to develop and validate algorithms for a physical activity monitoring system (PAMS) to detect wheelchair based activities. The PAMS consists of a gyroscope based wheel rotation monitor (G-WRM) and an accelerometer device (wocket) worn on the upper arm or on the wrist. A total of 45 persons with spinal cord injury took part in the study, which was performed in a structured university-based laboratory environment, a semi-structured environment at the National Veterans Wheelchair Games, and in the participants' home environments. Participants performed at least ten PAs, other than resting, taken from a list of PAs. The classification performance for the best classifiers on the testing dataset for PAMS-Arm (G-WRM and wocket on upper arm) and PAMS-Wrist (G-WRM and wocket on wrist) was 89.26% and 88.47%, respectively. The outcomes of this study indicate that multi-modal information from the PAMS can help detect various types of wheelchair-based activities in structured laboratory, semi-structured organizational, and unstructured home environments. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  5. Prediction of applied forces in handrim wheelchair propulsion.

    PubMed

    Lin, Chien-Ju; Lin, Po-Chou; Guo, Lan-Yuen; Su, Fong-Chin

    2011-02-03

    Researchers of wheelchair propulsion have usually suggested that a wheelchair can be properly designed using anthropometrics to reduce high mechanical load and thus reduce pain and damage to joints. A model based on physiological features and biomechanical principles can be used to determine anthropometric relationships for wheelchair fitting. To improve the understanding of man-machine interaction and the mechanism through which propulsion performance been enhanced, this study develops and validates an energy model for wheelchair propulsion. Kinematic data obtained from ten able-bodied and ten wheelchair-dependent users during level propulsion at an average velocity of 1m/s were used as the input of a planar model with the criteria of increasing efficiency and reducing joint load. Results demonstrate that for both experienced and inexperienced users, predicted handrim contact forces agree with experimental data through an extensive range of the push. Significant deviations that were mostly observed in the early stage of the push phase might result from the lack of consideration of muscle dynamics and wrist joint biomechanics. The proposed model effectively verified the handrim contact force patterns during dynamic propulsion. Users do not aim to generate mechanically most effective forces to avoid high loadings on the joints. Copyright © 2010 Elsevier Ltd. All rights reserved.

  6. Assessment of three-dimensional joint kinematics of the upper limb during simulated swimming using wearable inertial-magnetic measurement units.

    PubMed

    Fantozzi, Silvia; Giovanardi, Andrea; Magalhães, Fabrício Anício; Di Michele, Rocco; Cortesi, Matteo; Gatta, Giorgio

    2016-01-01

    The analysis of the joint kinematics during swimming plays a fundamental role both in sports conditioning and in clinical contexts. Contrary to the traditional video analysis, wearable inertial-magnetic measurements units (IMMUs) allow to analyse both the underwater and aerial phases of the swimming stroke over the whole length of the swimming pool. Furthermore, the rapid calibration and short data processing required by IMMUs provide coaches and athletes with an immediate feedback on swimming kinematics during training. This study aimed to develop a protocol to assess the three-dimensional kinematics of the upper limbs during swimming using IMMUs. Kinematics were evaluated during simulated dry-land swimming trials performed in the laboratory by eight swimmers. A stereo-photogrammetric system was used as the gold standard. The results showed high coefficient of multiple correlation (CMC) values, with median (first-third quartile) of 0.97 (0.93-0.95) and 0.99 (0.97-0.99) for simulated front-crawl and breaststroke, respectively. Furthermore, the joint angles were estimated with an accuracy increasing from distal to proximal joints, with wrist indices showing median CMC values always higher than 0.90. The present findings represent an important step towards the practical use of technology based on IMMUs for the kinematic analysis of swimming in applied contexts.

  7. Inverse Kinematics for Upper Limb Compound Movement Estimation in Exoskeleton-Assisted Rehabilitation

    PubMed Central

    Cortés, Camilo; de los Reyes-Guzmán, Ana; Scorza, Davide; Bertelsen, Álvaro; Carrasco, Eduardo; Gil-Agudo, Ángel; Ruiz-Salguero, Oscar; Flórez, Julián

    2016-01-01

    Robot-Assisted Rehabilitation (RAR) is relevant for treating patients affected by nervous system injuries (e.g., stroke and spinal cord injury). The accurate estimation of the joint angles of the patient limbs in RAR is critical to assess the patient improvement. The economical prevalent method to estimate the patient posture in Exoskeleton-based RAR is to approximate the limb joint angles with the ones of the Exoskeleton. This approximation is rough since their kinematic structures differ. Motion capture systems (MOCAPs) can improve the estimations, at the expenses of a considerable overload of the therapy setup. Alternatively, the Extended Inverse Kinematics Posture Estimation (EIKPE) computational method models the limb and Exoskeleton as differing parallel kinematic chains. EIKPE has been tested with single DOF movements of the wrist and elbow joints. This paper presents the assessment of EIKPE with elbow-shoulder compound movements (i.e., object prehension). Ground-truth for estimation assessment is obtained from an optical MOCAP (not intended for the treatment stage). The assessment shows EIKPE rendering a good numerical approximation of the actual posture during the compound movement execution, especially for the shoulder joint angles. This work opens the horizon for clinical studies with patient groups, Exoskeleton models, and movements types. PMID:27403420

  8. Ulnar nerve lesion at the wrist and sport: A report of 8 cases compared with 45 non-sport cases.

    PubMed

    Seror, P

    2015-04-01

    Reporting clinical and electrodiagnostic characteristics of sport-related ulnar neuropathies at the wrist. Eight sport-related and 45 non-sport-related cases from 53 ulnar neuropathies at the wrist cases over 14 years. Sport-related ulnar neuropathies at the wrist cases were due to cycling (5 cases), kayaking (2 cases), and big-game fishing (1 case). No patient had sensory complaints in ulnar digits, and all had motor impairment. Conduction across the wrist with recording on the first dorsal interosseous muscle was impaired in all cases, with conduction block in 5. Two cyclists showed bilateral ulnar neuropathies at the wrist. All cases recovered within 2 to 6 months with sport discontinuation. Distal lesions of the deep motor branch were more frequent in sport- than non-sport-related cases. The 8 sport-related ulnar neuropathies at the wrist cases involved the deep motor branch. Conduction study to the first dorsal interosseous muscle across the wrist is the key to electrodiagnostics. Bilateral cases in cyclists does not require wrist imaging. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  9. A nondestructive, reproducible method of measuring joint reaction force at the distal radioulnar joint.

    PubMed

    Canham, Colin D; Schreck, Michael J; Maqsoodi, Noorullah; Doolittle, Madison; Olles, Mark; Elfar, John C

    2015-06-01

    To develop a nondestructive method of measuring distal radioulnar joint (DRUJ) joint reaction force (JRF) that preserves all periarticular soft tissues and more accurately reflects in vivo conditions. Eight fresh-frozen human cadaveric limbs were obtained. A threaded Steinmann pin was placed in the middle of the lateral side of the distal radius transverse to the DRUJ. A second pin was placed into the middle of the medial side of the distal ulna colinear to the distal radial pin. Specimens were mounted onto a tensile testing machine using a custom fixture. A uniaxial distracting force was applied across the DRUJ while force and displacement were simultaneously measured. Force-displacement curves were generated and a best-fit polynomial was solved to determine JRF. All force-displacement curves demonstrated an initial high slope where relatively large forces were required to distract the joint. This ended with an inflection point followed by a linear area with a low slope, where small increases in force generated larger amounts of distraction. Each sample was measured 3 times and there was high reproducibility between repeated measurements. The average baseline DRUJ JRF was 7.5 N (n = 8). This study describes a reproducible method of measuring DRUJ reaction forces that preserves all periarticular stabilizing structures. This technique of JRF measurement may also be suited for applications in the small joints of the wrist and hand. Changes in JRF can alter native joint mechanics and lead to pathology. Reliable methods of measuring these forces are important for determining how pathology and surgical interventions affect joint biomechanics. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  10. X-Ray Exam: Wrist

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Wrist KidsHealth / For Parents / X-Ray Exam: Wrist What's in this article? What ... Have Questions Print What It Is A wrist X-ray is a safe and painless test that ...

  11. Using walker during walking: a pilot study for health elder.

    PubMed

    Po-Chan, Yeh; Cherng-Yee, Leung

    2012-01-01

    Walker operation completely relies on the walker handle, however most marketed walkers possess two horizontal handles. Several researchers have suggested that horizontal handles might lead to wrist injury. Therefore, the purpose of this study is to assess the relevant design aspects of walker for elderly people. 28 elders participated in this study; when the experiment was started, subject walked on the tile for 3 meter distance twice by using walker. Data for analysis were selected at the corresponding wrist deviation and vertical force. The results showed that during walker using, the mean wrist deviation was greater than zero. The largest vertical force is significantly larger than the smallest one, and different wrist deviation occurred at three phases, the largest wrist deviation while raising walker is larger than the smallest one, however, no significant different was found between the largest and smallest wrist deviation while pressing walker. No significant correlation occurred between weight and wrist deviation. The correlation between weight and vertical force was significantly positive. With wrist deviation walker use may cause injury to upper-limb, however wrists remain in a neutral position during hand movement to prevent damage. The findings of this study should improve the design of walker handles to reduce the wrist deviations of users.

  12. Complications of wrist arthroscopy.

    PubMed

    Ahsan, Zahab S; Yao, Jeffrey

    2012-06-01

    The purpose of this systematic review was to address the incidence of complications associated with wrist arthroscopy. Given the paucity of information published on this topic, an all-inclusive review of published wrist arthroscopy complications was sought. Two independent reviewers performed a literature search using PubMed, Google Scholar, EBSCO, and Academic Megasearch using the terms "wrist arthroscopy complications," "complications of wrist arthroscopy," "wrist arthroscopy injury," and "wrist arthroscopy." Inclusion criteria were (1) Levels I to V evidence, (2) "complication" defined as an adverse outcome directly related to the operative procedure, and (3) explicit description of operative complications in the study. Eleven multiple-patient studies addressing complications of wrist arthroscopy from 1994 to 2010 were identified, with 42 complications reported from 895 wrist arthroscopy procedures, a 4.7% complication rate. Four case reports were also found, identifying injury to the dorsal sensory branch of the ulnar nerve, injury to the posterior interosseous nerve, and extensor tendon sheath fistula formation. This systematic review suggests that the previously documented rate of wrist arthroscopy complications may be underestimating the true incidence. The report of various complications provides insight to surgeons for improving future surgical techniques. Level IV, systematic review of Levels I-V studies. Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  13. The effectiveness of wrist guards for reducing wrist and elbow accelerations resulting from simulated forward falls.

    PubMed

    Burkhart, Timothy A; Andrews, David M

    2010-08-01

    The effectiveness of wrist guards and modifying elbow posture for reducing impact-induced accelerations at the wrist and elbow, for the purpose of decreasing upper extremity injury risk during forward fall arrest, has not yet been documented in living people. A seated human pendulum was used to simulate the impact conditions consistent with landing on outstretched arms during a forward fall. Accelerometers measured the wrist and elbow response characteristics of 28 subjects following impacts with and without a wrist guard, and with elbows straight or slightly bent. Overall, the wrist guard was very effective, with significant reductions in peak accelerations at the elbow in the axial and off-axis directions, and in the off-axis direction at the wrist by almost 50%. The effect of elbow posture as an intervention strategy was mixed; a change in magnitude and direction of the acceleration response was documented at the elbow, while there was little effect at the wrist. Unique evidence was presented in support of wrist guard use in activities like in-line skating where impacts to the hands are common. The elbow response clearly shows that more proximal anatomical structures also need to be monitored when assessing the effectiveness of injury prevention strategies.

  14. Usage Position and Virtual Keyboard Design Affect Upper-Body Kinematics, Discomfort, and Usability during Prolonged Tablet Typing

    PubMed Central

    Lin, Ming-I Brandon; Hong, Ruei-Hong; Chang, Jer-Hao; Ke, Xin-Min

    2015-01-01

    Purpose The increase in tablet usage allows people to perform computer work in non-traditional office environments. The aim of this study was to assess the effects of changes in tablet keyboard design on postures of the upper extremities and neck, discomfort, and usability under different usage positions during prolonged touch-typing. Methods Eighteen healthy participants familiar with touch-screen devices were randomized into three usage positions (desk, lap, and bed) and completed six, 60-minute typing sessions using three virtual keyboard designs (standard, wide, split). Electrogoniometers continuously measured the postures of the wrists, elbow, and neck. Body discomfort and system usability were evaluated by questionnaires before and immediately after each typing session. Results Separate linear mixed effects models on various postural measures and subjective ratings are conducted with usage position as the between-subject factors, keyboard design and typing duration as the with-in subject factors were conducted. Using the tablet in bed led to more extended wrists but a more natural elbow flexion than the desk position. The angled split virtual keyboard significantly reduced the extent of wrist ulnar deviation than the keyboard with either standard or wide design. However, little difference was observed across the usage position and keyboard design. When the postural data were compared between the middle and end of typing sessions, the wrists, elbow, and neck all exhibited a substantially increased range of joint movements (13% to 38%). The discomfort rating also increased significantly over time in every upper body region investigated. Additionally, the split keyboard design received a higher usability rating in the bed position, whereas participants had more satisfactory experience while using the wide keyboard in the traditional desk setting. Conclusions Prolonged use of tablets in non-traditional office environments may result in awkward postures in the upper body that may expose users to greater risks of developing musculoskeletal symptoms. Adequate virtual keyboard designs show the potential to alleviate some postural effects and improve the user experience without changing the tablet form factors. PMID:26629989

  15. Rasch analysis of the patient-rated wrist evaluation questionnaire.

    PubMed

    Esakki, Saravanan; MacDermid, Joy C; Vincent, Joshua I; Packham, Tara L; Walton, David; Grewal, Ruby

    2018-01-01

    The Patient-Rated Wrist Evaluation (PRWE) was developed as a wrist joint specific measure of pain and disability and evidence of sound validity has been accumulated through classical psychometric methods. Rasch analysis (RA) has been endorsed as a newer method for analyzing the clinical measurement properties of self-report outcome measures. The purpose of this study was to evaluate the PRWE using Rasch modeling. We employed the Rasch model to assess overall fit, response scaling, individual item fit, differential item functioning (DIF), local dependency, unidimensionality and person separation index (PSI). A convenience sample of 382 patients with distal radius fracture was recruited from the hand and upper limb clinic at large academic healthcare organization, London, Ontario, Canada, 6-month post-injury scores of the PRWE was used. RA was conducted on the 3 subscales (pain, specific activities, and usual activities) of the PRWE separately. The pain subscale adequately fit the Rasch model when item 4 "Pain - When it is at its worst" was deleted to eliminate non-uniform DIF by age group, and item 5 "How often do you have pain" was rescored by collapsing into 8 intervals to eliminate disordered thresholds. Uniform DIF for "Use my affected hand to push up from the chair" (by work status) and "Use bathroom tissue with my affected hand" (by injured hand) was addressed by splitting the items for analysis. After background rescoring of 2 items in pain subscale, 2 items in specific activities and 3 items in usual activities, all three subscales of the PRWE were well targeted and had high reliability (PSI = 0.86). These changes provided a unidimensional, interval-level scaled measure. Like a previous analysis of the Patient-Rated Wrist and Hand Evaluation, this study found the PRWE could be fit to the Rasch model with rescoring of multiple items. However, the modifications required to achieve fit were not the same across studies, our fit statistics also suggested one of the pain items should be deleted. This study adds to the pool of evidence supporting the PRWE, but cannot confidently provide a Rasch-based scoring algorithm.

  16. Patient-Reported Outcome Measures for Hand and Wrist Trauma

    PubMed Central

    Dacombe, Peter Jonathan; Amirfeyz, Rouin; Davis, Tim

    2016-01-01

    Background: Patient-reported outcome measures (PROMs) are important tools for assessing outcomes following injuries to the hand and wrist. Many commonly used PROMs have no evidence of reliability, validity, and responsiveness in a hand and wrist trauma population. This systematic review examines the PROMs used in the assessment of hand and wrist trauma patients, and the evidence for reliability, validity, and responsiveness of each measure in this population. Methods: A systematic review of Pubmed, Medline, and CINAHL searching for randomized controlled trials of patients with traumatic injuries to the hand and wrist was carried out to identify the PROMs. For each identified PROM, evidence of reliability, validity, and responsiveness was identified using a further systematic review of the Pubmed, Medline, CINAHL, and reverse citation trail audit procedure. Results: The PROM used most often was the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire; the Patient-Rated Wrist Evaluation (PRWE), Gartland and Werley score, Michigan Hand Outcomes score, Mayo Wrist Score, and Short Form 36 were also commonly used. Only the DASH and PRWE have evidence of reliability, validity, and responsiveness in patients with traumatic injuries to the hand and wrist; other measures either have incomplete evidence or evidence gathered in a nontraumatic population. Conclusions: The DASH and PRWE both have evidence of reliability, validity, and responsiveness in a hand and wrist trauma population. Other PROMs used to assess hand and wrist trauma patients do not. This should be considered when selecting a PROM for patients with traumatic hand and wrist pathology. PMID:27418884

  17. The effectiveness of exercise for the management of musculoskeletal disorders and injuries of the elbow, forearm, wrist, and hand: a systematic review by the Ontario Protocol for Traffic Injury Management (OPTIMa) collaboration.

    PubMed

    Menta, Roger; Randhawa, Kristi; Côté, Pierre; Wong, Jessica J; Yu, Hainan; Sutton, Deborah; Varatharajan, Sharanya; Southerst, Danielle; D'Angelo, Kevin; Cox, Jocelyn; Brown, Courtney; Dion, Sarah; Mior, Silvano; Stupar, Maja; Shearer, Heather M; Lindsay, Gail M; Jacobs, Craig; Taylor-Vaisey, Anne

    2015-09-01

    The purpose of this systematic review was to evaluate the effectiveness of exercise compared to other interventions, placebo/sham intervention, or no intervention in improving self-rated recovery, functional recovery, clinical, and/or administrative outcomes in individuals with musculoskeletal disorders and injuries of the elbow, forearm, wrist, and hand. We searched MEDLINE, EMBASE, CINAHL, PsycINFO, and the Cochrane Central Register of Controlled Trials from 1990 to 2015. Paired reviewers independently screened studies for relevance and assessed the risk of bias using the Scottish Intercollegiate Guidelines Network criteria. We synthesized the evidence using the best evidence synthesis methodology. We identified 5 studies with a low risk of bias. Our review suggests that, for patients with persistent lateral epicondylitis, (1) adding concentric or eccentric strengthening exercises to home stretching exercises provides no additional benefits; (2) a home program of either eccentric or concentric strengthening exercises leads to similar outcomes; (3) home wrist extensor strengthening exercises lead to greater short-term improvements in pain reduction compared to "wait and see"; and (4) clinic-based, supervised exercise may be more beneficial than home exercises with minimal improvements in pain and function. For hand pain of variable duration, supervised progressive strength training added to advice to continue normal physical activity provides no additional benefits. The relative effectiveness of stretching vs strengthening for the wrist extensors remains unknown for the management of persistent lateral epicondylitis. The current evidence shows that the addition of supervised progressive strength training does not provide further benefits over advice to continue normal physical activity for hand pain of variable duration. Copyright © 2015 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.

  18. Trigger wrist caused by avascular necrosis of the capitate: a case report.

    PubMed

    Matsui, Yuichiro; Kawamura, Daisuke; Kida, Hiroaki; Hatanaka, Kanako C; Iwasaki, Norimasa

    2018-03-27

    Trigger wrist is a rare condition first described by Marti in 1960, and various causes have been reported. The condition mostly occurs with finger flexion and extension, and rarely with flexion and extension of the wrist itself. Avascular necrosis of the capitate is also a rare condition, first described by Jönsson in 1942. While some reports of this condition have been published, little is known about its etiology. Therefore, no established treatment exists. We report a case of trigger wrist caused by avascular necrosis of the capitate. A 16-year-old right-handed male who was a high school handball player was referred to our department from a nearby hospital 5 months after the onset of pain in the dorsal aspect of the right wrist, with an unknown cause. At the previous hospital, imaging findings led to a diagnosis of avascular necrosis of the capitate, and conservative treatment with a wrist brace did not improve the pain. At the initial visit to our department, the patient was noted to have a painful trigger wrist that was brought on by wrist flexion and extension. Preoperative imaging findings led to a diagnosis of trigger wrist caused by capitolunate instability secondary to avascular necrosis of the capitate. We performed a partial excision of the proximal capitate with tendon ball interposition. Two years after surgery, the patient's clinical outcome was favorable, with no recurrence of wrist pain or triggering. Both trigger wrist and avascular necrosis of the capitate are rare disorders. When a patient presents with painful triggering at the wrist, surgeons must bear in mind that avascular necrosis of the capitate may result in this phenomenon. We recommend partial excision of the proximal capitate with tendon ball interposition for the treatment of this lesion.

  19. Current Status of Efforts on Standardizing Magnetic Resonance Imaging of Juvenile Idiopathic Arthritis: Report from the OMERACT MRI in JIA Working Group and Health-e-Child.

    PubMed

    Nusman, Charlotte M; Ording Muller, Lil-Sofie; Hemke, Robert; Doria, Andrea S; Avenarius, Derk; Tzaribachev, Nikolay; Malattia, Clara; van Rossum, Marion A J; Maas, Mario; Rosendahl, Karen

    2016-01-01

    To report on the progress of an ongoing research collaboration on magnetic resonance imaging (MRI) in juvenile idiopathic arthritis (JIA) and describe the proceedings of a meeting, held prior to Outcome Measures in Rheumatology (OMERACT) 12, bringing together the OMERACT MRI in JIA working group and the Health-e-Child radiology group. The goal of the meeting was to establish agreement on scoring definitions, locations, and scales for the assessment of MRI of patients with JIA for both large and small joints. The collaborative work process included premeeting surveys, presentations, group discussions, consensus on scoring methods, pilot scoring, conjoint review, and discussion of a future research agenda. The meeting resulted in preliminary statements on the MR imaging protocol of the JIA knee and wrist and determination of the starting point for development of MRI scoring systems based on previous studies. It was also considered important to be descriptive rather than explanatory in the assessment of MRI in JIA (e.g., "thickening" instead of "hypertrophy"). Further, the group agreed that well-designed calibration sessions were warranted before any future scoring exercises were conducted. The combined efforts of the OMERACT MRI in JIA working group and Health-e-Child included the assessment of currently available material in the literature and determination of the basis from which to start the development of MRI scoring systems for both the knee and wrist. The future research agenda for the knee and wrist will include establishment of MRI scoring systems, an atlas of MR imaging in healthy children, and MRI protocol requisites.

  20. Diagnostic utility of sonography and correlation between sonographic and clinical findings in patients with carpal tunnel syndrome.

    PubMed

    Tajika, Tsuyoshi; Kobayashi, Tsutomu; Yamamoto, Atsushi; Kaneko, Tetsuya; Takagishi, Kenji

    2013-11-01

    First, we investigated the accuracy of carpal tunnel syndrome diagnosis by comparing the cross-sectional area of the median nerve measured at the level of proximal inlet of the carpal tunnel with that measured at the level of the distal radioulnar joint on sonography. Second, we evaluated the correlation between sonographic and neurophysiologic findings and clinical findings assessed by the Carpal Tunnel Syndrome Instrument of the Japanese Society for Surgery of the Hand (JSSH). Fifty wrists in 34 patients and 81 wrists in 45 healthy volunteers were examined. The proximal cross-sectional area and the difference (Δ) between the proximal and distal cross-sectional areas were calculated for each wrist. Nerve conduction velocity tests were performed for all patients with carpal tunnel syndrome. The proximal, distal, and Δ cross-sectional areas were compared for the two groups. We examined the correlation between the proximal, distal, and Δ areas, nerve conduction velocity findings, and JSSH scores in the patients. The diagnosis of carpal tunnel syndrome determined by the Δ cross-sectional area was more accurate than the diagnosis determined by the proximal area on receiver operating characteristic curve analysis (P = .006). Statistically significant correlations were found between proximal area, Δ area, and nerve conduction velocity findings (proximal, r = 0.45; P = .0013; Δ, r = 0.44; P = .001). The proximal and distal areas were positively correlated with the JSSH symptom severity score (proximal, r= 0.39; P= .005; distal, r = 0.35; P = .014). The cross-sectional area method using sonography has excellent performance for diagnosing carpal tunnel syndrome. It was useful for measuring the proximal and distal cross-sectional areas to evaluated the symptom severity and for calculating the Δ cross-sectional area to assess motor nerve damage in patients with carpal tunnel syndrome.

  1. How well can step-off and gap distances be reduced when treating intra-articular distal radius fractures with fragment specific fixation when using fluoroscopy.

    PubMed

    Thiart, M; Ikram, A; Lamberts, R P

    2016-12-01

    Although fragment specific fixation has proved to be an effective treatment regime, it has not been established how successfully this treatment could be performed using fluoroscopy and what the added value of arthroscopy could be. Establish gap and step-off distances after in intra-articular distal radius fractures that have been treated with fragment specific fixation while using fluoroscopy. Forty-four patients with an intra-articular distal radius fracture were treated with fragment specific fixation while using fluoroscopy. After the treatment of the intra-articular distal radius fracture with fragment specific fixation and the use of fluoroscopy, but before the completion of the surgical intervention, all gap, and step-off distances were determined by using arthroscopy. In addition, the joint was checked for any other wrist pathologies. Arthroscopy after the surgical intervention showed that in 37 patients no gap distances could be detected, while in six patients a gap distance of≤2mm was found and in one patient, a gap distance of 3mm. Similarly, arthroscopy revealed no step-off distances in 33 patients, while in 11 patients a step-off distance of≤2mm was found. Although additional wrist pathologies were found in 48% of our population, only one patient needed surgical intervention. Three months after the surgical intervention wrist flexion was 41±10°, wrist extension 51±17°, ulnar deviation 19±10°, radial deviation 32±12° while patients could pronate and supinate their wrist to 85±5° and 74±20°, respectively. Intra-articular distal radius fractures can be treated successfully with fragment specific fixation and the use of fluoroscopy. As almost all gap and step-off distances could be reduced to an acceptable level, the scope for arthroscopy to further improve this treatment regime is limited. The functional outcome scores that were found 3 months after the surgical intervention were similar to what has been reported in other studies using different treatment option. These findings suggest that fragment specific fixation is a good alternative for treating intra-articular distal radius fractures. As in most cases, only fluoroscopy is needed for fragment specific fixation, this treatment technique is a good treatment option for resource-limited hospitals, setting who do not have access to arthroscopy. III, case-control study. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  2. Can validated wrist devices with position sensors replace arm devices for self-home blood pressure monitoring? A randomized crossover trial using ambulatory monitoring as reference.

    PubMed

    Stergiou, George S; Christodoulakis, George R; Nasothimiou, Efthimia G; Giovas, Periklis P; Kalogeropoulos, Petros G

    2008-07-01

    Electronic devices that measure blood pressure (BP) at the arm level are regarded as more accurate than wrist devices and are preferred for home BP (HBP) monitoring. Recently, wrist devices with position sensors have been successfully validated using established protocols. This study assessed whether HBP values measured with validated wrist devices are sufficiently reliable to be used for making patient-related decisions in clinical practice. This randomized crossover study compared HBP measurements taken using validated wrist devices (wrist-HBP, Omron R7 with position sensor) with those taken using arm devices (arm-HBP, Omron 705IT), and also with measurements of awake ambulatory BP (ABP, SpaceLabs), in 79 subjects (36 men and 43 women) with hypertension. The mean age of the study population was 56.7 +/- 11.8 years, and 33 of the subjects were not under treatment for hypertension. The average arm-HBP was higher than the average wrist-HBP (mean difference, systolic 5.2 +/- 9.1 mm Hg, P < 0.001, and diastolic 2.2 +/- 6.7, P < 0.01). Twenty-seven subjects (34%) had a > or =10 mm Hg difference between systolic wrist-HBP and arm-HBP and twelve subjects (15%) showed similar levels of disparity in diastolic HBP readings. Strong correlations were found between arm-HBP and wrist-HBP (r 0.74/0.74, systolic/diastolic, P < 0.0001). However, ABP was more strongly correlated with arm-HBP (r 0.73/0.76) than with wrist-HBP (0.55/0.69). The wrist-arm HBP difference was associated with systolic ABP (r 0.34) and pulse pressure (r 0.29), but not with diastolic ABP, sex, age, arm circumference, and wrist circumference. There might be important differences in HBP measured using validated wrist devices with position sensor vs. arm devices, and these could impact decisions relating to the patient in clinical practice. Measurements taken using arm devices are more closely related to ABP values than those recorded by wrist devices. More research is needed before recommending the widespread use of wrist monitors in clinical practice. American Journal of Hypertension doi:10.1038/ajh.2008.176American Journal of Hypertension (2008); 21, 7, 753-758. doi:10.1038/ajh.2008.176.

  3. The Amsterdam wrist rules: the multicenter prospective derivation and external validation of a clinical decision rule for the use of radiography in acute wrist trauma.

    PubMed

    Walenkamp, Monique M J; Bentohami, Abdelali; Slaar, Annelie; Beerekamp, M Suzan H; Maas, Mario; Jager, L Cara; Sosef, Nico L; van Velde, Romuald; Ultee, Jan M; Steyerberg, Ewout W; Goslings, J Carel; Schep, Niels W L

    2015-12-18

    Although only 39 % of patients with wrist trauma have sustained a fracture, the majority of patients is routinely referred for radiography. The purpose of this study was to derive and externally validate a clinical decision rule that selects patients with acute wrist trauma in the Emergency Department (ED) for radiography. This multicenter prospective study consisted of three components: (1) derivation of a clinical prediction model for detecting wrist fractures in patients following wrist trauma; (2) external validation of this model; and (3) design of a clinical decision rule. The study was conducted in the EDs of five Dutch hospitals: one academic hospital (derivation cohort) and four regional hospitals (external validation cohort). We included all adult patients with acute wrist trauma. The main outcome was fracture of the wrist (distal radius, distal ulna or carpal bones) diagnosed on conventional X-rays. A total of 882 patients were analyzed; 487 in the derivation cohort and 395 in the validation cohort. We derived a clinical prediction model with eight variables: age; sex, swelling of the wrist; swelling of the anatomical snuffbox, visible deformation; distal radius tender to palpation; pain on radial deviation and painful axial compression of the thumb. The Area Under the Curve at external validation of this model was 0.81 (95 % CI: 0.77-0.85). The sensitivity and specificity of the Amsterdam Wrist Rules (AWR) in the external validation cohort were 98 % (95 % CI: 95-99 %) and 21 % (95 % CI: 15 %-28). The negative predictive value was 90 % (95 % CI: 81-99 %). The Amsterdam Wrist Rules is a clinical prediction rule with a high sensitivity and negative predictive value for fractures of the wrist. Although external validation showed low specificity and 100 % sensitivity could not be achieved, the Amsterdam Wrist Rules can provide physicians in the Emergency Department with a useful screening tool to select patients with acute wrist trauma for radiography. The upcoming implementation study will further reveal the impact of the Amsterdam Wrist Rules on the anticipated reduction of X-rays requested, missed fractures, Emergency Department waiting times and health care costs. This study was registered in the Dutch Trial Registry, reference number NTR2544 on October 1(st), 2010.

  4. Functional disability associated with disease and quality-of-life parameters in Chinese patients with rheumatoid arthritis.

    PubMed

    Ji, Juan; Zhang, Lijuan; Zhang, Qiuxiang; Yin, Rulan; Fu, Ting; Li, Liren; Gu, Zhifeng

    2017-05-02

    As an important outcome measure among rheumatoid arthritis (RA) patients, functional disability may contribute to unemployment, loss of work productivity, and impaired quality of life. However, little is known about the risk factors of functional disability in Chinese RA patients. This study aimed (1) to examine the prevalence of functional disability in Chinese RA patients; (2) to explore factors associated with the health assessment questionnaire-disability index (HAQ-DI). A total of 101 RA patients in this cross-sectional study underwent standardized laboratory examinations and responded to the questionnaire for demographic data, the HAQ-DI for functional disability, the Compliance Questionnaire on Rheumatology (CQR) for medication adherence, the Hospital Anxiety and Depression Scale (HADS) for psychological status, and the Short Form 36 health survey (SF-36) for quality of life. Pain, grip/pinch strength, disease activity, and large joint mobility were recorded. Independent samples t-tests, chi-square analyses, and logistic regression modeling were used to analyze the data. The mean ± SD age of RA patients was 54.9 ± 11.9 years. Approximately 15.8% RA patients in mainland China experience functional disability (defined as a HAQ-DI score ≥ 1). Long disease duration, pain, high disease activity, a larger number of tender and swollen joints, high C-reactive protein (CRP) level, decreased grip strength, and limitation of shoulder, elbow, wrist, knee, and ankle motion were associated with the HAQ-DI. Participants with functional disability tended to have more severe depressive symptoms and a lower quality of life compared with individuals without functional disability. Stepwise logistic regression analyses found that limitation of wrist extension (P = 0.001) and lower body pain (BP) score (P = 0.001) explained higher HAQ-DI score. The present study reported that functional disability was common in Chinese RA patients. A low quality of life and limitation of joint mobility had great impacts on functional disability in Chinese RA patients. Targeted and culturally sensitive interventions should be strengthened to delay the onset of disabilities of this population.

  5. How was the Turin Shroud Man crucified?

    PubMed

    Bevilacqua, M; Fanti, G; D'Arienzo, M; Porzionato, A; Macchi, V; De Caro, R

    2014-12-01

    As the literature is not exhaustive with reference to the way the Turin Shroud (TS) Man was crucified, and it is not easy to draw significant information from only a "photograph" of a man on a linen sheet, this study tries to add some detail on this issue based on both image processing of high resolution photos of the TS and on experimental tests on arms and legs of human cadavers. With regard to the TS Man hands, a first hypothesis states that the left hand of the TS Man was nailed twice at two different anatomical sites: the midcarpal joint medially to the pisiform between the lunate/pyramidal and capitate/uncinate bones (Destot's space) and the radiocarpal joint between the radio, lunate and scaphoid; also the right hand would have been nailed twice. A second hypothesis, preferred by the authors, states that the hands were nailed only once in the Destot's space with partial lesion of the ulnar nerve and flexion of the metacarpophalangeal joint of the thumbs. With regard to the TS Man feet, the imprint of the sole of the right foot leads to the conclusion that TS Man suffered a dislocation at the ankle just before the nailing. The entrance hole of the nail on the right foot is a few inches from the ankle, and excludes a double nailing. The nail has been driven between the tarsal bones. The TS Man suffered the following tortures during crucifixion: a very serious and widespread causalgia due to total paralysis of the upper right limb (paradoxical causalgia); a nailing of the left wrist with damage to the ulnar nerve; a similar nailing of the right wrist; and a nailing to both feet using one only nail that injured the plantaris medialis nerves. The respiratory limitation was probably not sufficient to cause death by asphyxiation. Also considering the hypovolemia produced by scourging and the many other tortures detectable on the TS, the principal cause of death can be attributed to a myocardial infarction. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Sports-Related Wrist Injuries in Adults

    PubMed Central

    Chen, Neal C.; Jupiter, Jesse B.; Jebson, Peter J. L.

    2009-01-01

    Background: Wrist injuries are common in sports. Those who are involved in the care of athletes should be familiar with hand and wrist anatomy, common wrist injuries, and clinical examination; they should also know how to recognize emergent problems. Level of Evidence: Level V, expert opinion. PMID:23015908

  7. Comparison of Compliance and Intervention Outcomes Between Hip- and Wrist-Worn Accelerometers During a Randomized Crossover Trial of an Active Video Games Intervention in Children.

    PubMed

    Howie, Erin K; McVeigh, Joanne A; Straker, Leon M

    2016-09-01

    There are several practical issues when considering the use of hip-worn or wrist-worn accelerometers. This study compared compliance and outcomes between hip- and wrist-worn accelerometers worn simultaneously by children during an active video games intervention. As part of a larger randomized crossover trial, participants (n = 73, age 10 to 12 years) wore 2 Actical accelerometers simultaneously during waking hours for 7 days, on the hip and wrist. Measurements were repeated at 4 timepoints: 1) at baseline, 2) during traditional video games condition, 3) during active video games condition, 4) during no video games condition. Compliance and intervention effects were compared between hip and wrist. There were no statistically significant differences at any timepoint in percentage compliance between hip (77% to 87%) and wrist (79% to 89%). Wrist-measured counts (difference of 64.3 counts per minute, 95% CI 4.4-124.3) and moderate-to-vigorous physical activity (MVPA) (12 min/day, 95% CI 0.3-23.7) were higher during the no video games condition compared with the traditional video games condition. There were no differences in hip-measured counts per minute or MVPA between conditions or sedentary time for hip or wrist. There were no differences in compliance between hip- and wrist-worn accelerometers during an intervention trial, however, intervention findings differed between hip and wrist.

  8. [Theoretical origin and clinical application of wrist-ankle acupuncture therapy].

    PubMed

    Wang, Qiong; Zhou, Qinghui

    2017-05-12

    The theory of wrist-ankle acupuncture is consistent with traditional meridian-collateral theory. For example, the body divisions of wrist-ankle acupuncture are corresponding to the distribution of 12 cutaneous regions of meridians, the needling sites of it are to the running courses of 12 meridians; the indications of it are to those of 12 meridians. The needling sites of wrist-ankle acupuncture are relevant with some special acupoints of acupuncture theory. For example, the 12-needling sites of wrist-ankle acupuncture are located similar to those of 12 meridian points and have very similar indications. The needling sites of it are located in the wrist and ankle regions, in which the five- shu points are located nearby, for meridian disorders. Most luo -connecting points are located near to the needling sites of wrist-ankle acupuncture or the needle tip points to. Additionally, the needling method of wrist-ankle acupuncture is consistent with some of the subcutaneous needling methods in traditional acupuncture therapy. On the basis of the aspects mentioned above, it is explained that wrist-ankle acupuncture is the development of traditional acupuncture and cannot be independent from the traditional theories of acupuncture and meridians. It is necessary to seek for the evidence from the traditional theories of TCM. The traditional theories of TCM are summarized from clinical practice, which can be newly verified from the practice of wrist-ankle acupuncture.

  9. Arthroscopic-Assisted Triangular Fibrocartilage Complex Reconstruction.

    PubMed

    Chu-Kay Mak, Michael; Ho, Pak-Cheong

    2017-11-01

    Injury of the triangular fibrocartilage complex (TFCC) is a common cause of ulnar-sided wrist pain. Volar and dorsal radioulnar ligaments and their foveal insertion are the most important stabilizing components of the TFCC. In irreparable tears, anatomic reconstruction of the TFCC aims to restore normal biomechanics and stability of the distal radioulnar joint. We proposed a novel arthroscopic-assisted technique using a palmaris longus tendon graft. Arthroscopic-assisted TFCC reconstruction is a safe and effective approach with outcomes comparable to conventional open reconstruction and may result in a better range of motion from minimizing soft tissue dissection and subsequent scarring. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Arthroscopic Management of Triangular Fibrocartilage Complex Peripheral Injury.

    PubMed

    Haugstvedt, Jan Ragnar; Søreide, Endre

    2017-11-01

    Patients suffering from ulnar-sided wrist pain after trauma may develop tenderness, clicking, a positive fovea sign, or instability of the distal radioulnar joint. If the pain is persistent, conservative treatment does not help, and the patient agrees to surgery, arthroscopy may reveal a triangular fibrocartilage complex (TFCC) injury with capsular detachment, foveal avulsion, or a combination thereof. Capsular reattachment is possible using an arthroscopic assisted technique. The reattachment can be performed with an inside-out, outside-in, or all-inside technique, providing good to excellent results, which tend to persist over time, in 60% to 90% of cases. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Clinical Sign for Missed Decompression of a Separate Extensor Pollicis Brevis Compartment in de Quervain's Disease.

    PubMed

    Benatar, Niels

    2017-08-01

    Persistent pain despite previous surgery for de Quervain's disease might be due to an overlooked septum between the abductor pollicis longus tendon slips and the extensor pollicis brevis tendon, or an overlooked completely separate compartment for the extensor pollicis brevis tendon alone. In both of these instances, extension of the MP joint of the thumb against resistance elicits pain at the distal level of the first extensor compartment of the wrist. When this sign is positive, revisional surgery and decompression of the remaining septum or separate compartment is indicated. © Georg Thieme Verlag KG Stuttgart · New York.

  12. DETERMINATION OF THE RADIOSENSITIVITY OF DIFFERENT BONE GROWTH REGIONS USING Ca$sup 45$ METABOLISM (in German)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kolar, J.; Babicky, A.

    1961-02-01

    The radiation sensitivity of some bone segments and especially of the growth zones of white rats was examined with the help of Ca/sup 45/. The deviations in the specific activities corresponded not only to the delivered dosage but also to the growth activity of some of the bone segments. After large radiation doses and in more activity growth zones the radiation damage was also greater. These results should give reason in the clinical practice for greater caution in radiation treatment in the area of strongly growing epiphyseal zones (in the area of knee and wrist joints). (auth)

  13. Principles of Billing for Diagnostic Ultrasound in the Office and Operating Room.

    PubMed

    Grasu, Beatrice L; Wolock, Bruce S; Sedgley, Matthew D; Murphy, Michael S

    2018-05-08

    Ultrasound is becoming more prevalent as physicians gain comfort in its diagnostic and therapeutic uses. It allows for both static and dynamic evaluation of conditions and assists in therapeutic injections of joints and tendons. Proper technique is necessary for successful use of this modality. Appropriate coding for physician reimbursement is required. We discuss common wrist and hand pathology for which ultrasound may be useful as an adjunct to diagnosis and treatment and provide an overview of technique and reimbursement codes when using ultrasound in a variety of situations. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  14. KSC-02pd0847

    NASA Image and Video Library

    2002-05-30

    KENNEDY SPACE CENTER, FLA. -- In the Press Site auditorium, space agency officials participate in a media briefing following the launch scrub of Space Shuttle mission STS-111. From left are NASA Administrator Sean O'Keefe, French Space Agency President Dr. Alain Bensoussan, and Canadian Space Agency President Dr. Marc Garneau. STS-111 is the second Utilization Flight to the International Space Station, carrying the Multi-Purpose Logistics Module Leonardo, the Mobile Base System (MBS), and a replacement wrist/roll joint for the Canadarm 2. Also on board will be the Expedition Five crew who will replace Expedition Four on the Station. Launch is rescheduled for May 31 at 7:22 p.m. EDT

  15. Patient-Reported Outcome Measures for Hand and Wrist Trauma: Is There Sufficient Evidence of Reliability, Validity, and Responsiveness?

    PubMed

    Dacombe, Peter Jonathan; Amirfeyz, Rouin; Davis, Tim

    2016-03-01

    Patient-reported outcome measures (PROMs) are important tools for assessing outcomes following injuries to the hand and wrist. Many commonly used PROMs have no evidence of reliability, validity, and responsiveness in a hand and wrist trauma population. This systematic review examines the PROMs used in the assessment of hand and wrist trauma patients, and the evidence for reliability, validity, and responsiveness of each measure in this population. A systematic review of Pubmed, Medline, and CINAHL searching for randomized controlled trials of patients with traumatic injuries to the hand and wrist was carried out to identify the PROMs. For each identified PROM, evidence of reliability, validity, and responsiveness was identified using a further systematic review of the Pubmed, Medline, CINAHL, and reverse citation trail audit procedure. The PROM used most often was the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire; the Patient-Rated Wrist Evaluation (PRWE), Gartland and Werley score, Michigan Hand Outcomes score, Mayo Wrist Score, and Short Form 36 were also commonly used. Only the DASH and PRWE have evidence of reliability, validity, and responsiveness in patients with traumatic injuries to the hand and wrist; other measures either have incomplete evidence or evidence gathered in a nontraumatic population. The DASH and PRWE both have evidence of reliability, validity, and responsiveness in a hand and wrist trauma population. Other PROMs used to assess hand and wrist trauma patients do not. This should be considered when selecting a PROM for patients with traumatic hand and wrist pathology.

  16. [Relieving pre-exam anxiety syndrome with wrist-ankle acupuncture: a randomized controlled trial].

    PubMed

    Shu, Shi; Li, Tong-ming; Fang, Fan-fu; He, Hou-luo; Zhou, Qing-hui; Gu, Wei; Zhou, Shuang

    2011-06-01

    Pre-exam anxiety syndrome is a common condition occurring in pre-exam students and directly affects their examination performance and physical state. Wrist-ankle acupuncture has significant therapeutic effects in treating mental disorders and may also relieve the symptoms of pre-exam anxiety syndrome. To assess the therapeutic effect of wrist-ankle acupuncture on pre-exam anxiety syndrome. A total of 60 students who met the inclusion criteria of pre-exam anxiety syndrome were enrolled from a university in Shanghai and they were randomly divided into treatment group and control group. There were 30 cases in each group, and no case failed to follow-up. In the treatment group, wrist-ankle acupuncture was adopted to point upper 1 bilaterally (impression between flexor carpi ulnaris tendon and ulnar margin), and there was no requirement for Deqi (arrival of qi). In the control group, sham acupuncture was adopted. The treatment was applied 3 times totally in both groups one week before the exam, once every other day, each time with the needles retained for 30 min. The therapeutic effects were compared between two groups. Before and after 3 treatments, Sarason Test Anxiety Scale (TAS) and Expectation and Treatment Credibility Scale (ETCS) were measured and evaluated. The therapeutic effect experienced by the treatment group was better than that of the control group (P<0.05). There were no statistically significant differences in TAS and ETCS before treatment between the two groups. The scores of TAS after treatment in two groups were higher than those before treatment (P<0.05, P<0.01). There were statistical differences in TAS absolute difference and TAS relative difference between the two groups and the treatment group had better results (P<0.05, P<0.01). After treatment, patients in the treatment group had higher scores in ETCS than those in the control group (P<0.05, P<0.01). No adverse reaction was reported. Wrist-ankle acupuncture can relieve the symptoms of pre-exam anxiety syndrome significantly, and this therapy is highly safe.

  17. ESCAPS study protocol: a feasibility randomised controlled trial of ‘Early electrical stimulation to the wrist extensors and wrist flexors to prevent the post-stroke complications of pain and contractures in the paretic arm’

    PubMed Central

    Fletcher-Smith, Joanna C; Walker, Dawn-Marie; Sprigg, Nikola; James, Marilyn; Walker, Marion F; Allatt, Kate; Mehta, Rajnikant; Pandyan, Anand D

    2016-01-01

    Introduction Approximately 70% of patients with stroke experience impaired arm function, which is persistent and disabling for an estimated 40%. Loss of function reduces independence in daily activities and impacts on quality of life. Muscles in those who do not recover functional movement in the stroke affected arm are at risk of atrophy and contractures, which can be established as early as 6 weeks following stroke. Pain is also common. This study aims to evaluate the feasibility of a randomised controlled trial to test the efficacy and cost-effectiveness of delivering early intensive electrical stimulation (ES) to prevent post-stroke complications in the paretic upper limb. Methods and analysis This is a feasibility randomised controlled trial (n=40) with embedded qualitative studies (patient/carer interviews and therapist focus groups) and feasibility economic evaluation. Patients will be recruited from the Stroke Unit at the Nottingham University Hospitals National Health Service (NHS) Trust within 72 h after stroke. Participants will be randomised to receive usual care or usual care and early ES to the wrist flexors and extensors for 30 min twice a day, 5 days a week for 3 months. The initial treatment(s) will be delivered by an occupational therapist or physiotherapist who will then train the patient and/or their nominated carer to self-manage subsequent treatments. Ethics and dissemination This study has been granted ethical approval by the National Research Ethics Service, East Midlands Nottingham1 Research Ethics Committee (ref: 15/EM/0006). To our knowledge, this is the first study of its kind of the early application (within 72 h post-stroke) of ES to both the wrist extensors and wrist flexors of stroke survivors with upper limb impairment. The results will inform the design of a definitive randomised controlled trial. Dissemination will include 2 peer-reviewed journal publications and presentations at national conferences. Trial registration number ISRCTN1648908; Pre-results. Clinicaltrials.gov ID: NCT02324634. PMID:26729394

  18. Joint University Program for Air Transportation Research, 1984

    NASA Technical Reports Server (NTRS)

    Morrell, Frederick R. (Compiler)

    1987-01-01

    The research conducted during 1984 under the NASA/FAA sponsored Joint University Program for Air Transportation Research is summarized. The Joint University Program is a coordinated set of three grants sponsored by NASA Langley Research Center and the Federal Aviation Administration, one each with the Massachusetts Institute of Technology, Ohio University, and Princeton University. Completed works, status reports, and bibliographies are presented for research topics, which include navigation, guidance, control and display concepts. An overview of the year's activities for each of the schools is also presented.

  19. A randomized, double-blind, controlled study of ultrasound-guided corticosteroid injection into the joint of patients with inflammatory arthritis.

    PubMed

    Cunnington, Joanna; Marshall, Nicola; Hide, Geoff; Bracewell, Claire; Isaacs, John; Platt, Philip; Kane, David

    2010-07-01

    Most corticosteroid injections into the joint are guided by the clinical examination (CE), but up to 70% are inaccurately placed, which may contribute to an inadequate response. The aim of this study was to investigate whether ultrasound (US) guidance improves the accuracy and clinical outcome of joint injections as compared with CE guidance in patients with inflammatory arthritis. A total of 184 patients with inflammatory arthritis and an inflamed joint (shoulder, elbow, wrist, knee, or ankle) were randomized to receive either US-guided or CE-guided corticosteroid injections. Visual analog scales (VAS) for assessment of function, pain, and stiffness of the target joint, a modified Health Assessment Questionnaire, and the EuroQol 5-domain questionnaire were obtained at baseline and at 2 weeks and 6 weeks postinjection. The erythrocyte sedimentation rate and C-reactive protein level were measured at baseline and 2 weeks. Contrast injected with the steroid was used to assess the accuracy of the joint injection. One-third of CE-guided injections were inaccurate. US-guided injections performed by a trainee rheumatologist were more accurate than the CE-guided injections performed by more senior rheumatologists (83% versus 66%; P = 0.010). There was no significant difference in clinical outcome between the group receiving US-guided injections and the group receiving CE-guided injections. Accurate injections led to greater improvement in joint function, as determined by VAS scores, at 6 weeks, as compared with inaccurate injections (30.6 mm versus 21.2 mm; P = 0.030). Clinicians who used US guidance reliably assessed the accuracy of joint injection (P < 0.001), whereas those who used CE guidance did not (P = 0.29). US guidance significantly improves the accuracy of joint injection, allowing a trainee to rapidly achieve higher accuracy than more experienced rheumatologists. US guidance did not improve the short-term outcome of joint injection.

  20. Population Coding of Forelimb Joint Kinematics by Peripheral Afferents in Monkeys

    PubMed Central

    Umeda, Tatsuya; Seki, Kazuhiko; Sato, Masa-aki; Nishimura, Yukio; Kawato, Mitsuo; Isa, Tadashi

    2012-01-01

    Various peripheral receptors provide information concerning position and movement to the central nervous system to achieve complex and dexterous movements of forelimbs in primates. The response properties of single afferent receptors to movements at a single joint have been examined in detail, but the population coding of peripheral afferents remains poorly defined. In this study, we obtained multichannel recordings from dorsal root ganglion (DRG) neurons in cervical segments of monkeys. We applied the sparse linear regression (SLiR) algorithm to the recordings, which selects useful input signals to reconstruct movement kinematics. Multichannel recordings of peripheral afferents were performed by inserting multi-electrode arrays into the DRGs of lower cervical segments in two anesthetized monkeys. A total of 112 and 92 units were responsive to the passive joint movements or the skin stimulation with a painting brush in Monkey 1 and Monkey 2, respectively. Using the SLiR algorithm, we reconstructed the temporal changes of joint angle, angular velocity, and acceleration at the elbow, wrist, and finger joints from temporal firing patterns of the DRG neurons. By automatically selecting a subset of recorded units, the SLiR achieved superior generalization performance compared with a regularized linear regression algorithm. The SLiR selected not only putative muscle units that were responsive to only the passive movements, but also a number of putative cutaneous units responsive to the skin stimulation. These results suggested that an ensemble of peripheral primary afferents that contains both putative muscle and cutaneous units encode forelimb joint kinematics of non-human primates. PMID:23112841

Top