Sample records for universal polarimeter soup

  1. Intercomparison of SOUP, ASP, LPSP, and MDI magnetograms

    NASA Astrophysics Data System (ADS)

    Berger, T.; Lites, B.; Martinez-Pillet, V.; Tarbell, T.; Title, A.

    2001-05-01

    We compare simultaneous magnetograms of a solar active region taken by the Advanced Stokes Polarimeter (ASP) and the Solar Optical Universal Polimeter (SOUP) in 1998. In addition we compare magnetograms taken by the La Palma Stokes Polarimeter (LPSP), the Michelson Doppler Imager (MDI) on SOHO, and the SOUP instrument in 2000. The SOUP instrument on the Swedish Vacuum Solar Telescope (SVST) attains the highest spatial resolution but has the least understood calibration; the ASP on the Dunn Solar Telescope (DST) at Sacramento Peak attains the highest magnetic field precision. The goal of the program is to better quantify the SOUP magnetograms and thereby study magnetic element dynamics in the photosphere with higher precision.

  2. A solar magnetic and velocity field measurement system for Spacelab 2: The Solar Optical Universal Polarimeter (SOUP)

    NASA Technical Reports Server (NTRS)

    Tarbell, Theodore D.; Title, Alan M.

    1992-01-01

    The Solar Optical Universal Polarimeter (SOUP) flew on the shuttle mission Spacelab 2 (STS-51F) in August, 1985, and collected historic solar observations. SOUP is the only solar telescope on either a spacecraft or balloon which has delivered long sequences of diffraction-limited images. These movies led to several discoveries about the solar atmosphere which were published in the scientific journals. After Spacelab 2, reflights were planned on the shuttle Sunlab mission, which was cancelled after the Challenger disaster, and on a balloon flights, which were also cancelled for funding reasons. In the meantime, the instrument was used in a productive program of ground-based observing, which collected excellent scientific data and served as instrument tests. Given here is an overview of the history of the SOUP program, the scientific discoveries, and the instrument design and performance.

  3. A solar magnetic and velocity field measurement system for Spacelab 2: The Solar Optical Universal Polarimeter (SOUP)

    NASA Astrophysics Data System (ADS)

    Tarbell, Theodore D.; Title, Alan M.

    1992-08-01

    The Solar Optical Universal Polarimeter (SOUP) flew on the shuttle mission Spacelab 2 (STS-51F) in August, 1985, and collected historic solar observations. SOUP is the only solar telescope on either a spacecraft or balloon which has delivered long sequences of diffraction-limited images. These movies led to several discoveries about the solar atmosphere which were published in the scientific journals. After Spacelab 2, reflights were planned on the shuttle Sunlab mission, which was cancelled after the Challenger disaster, and on a balloon flights, which were also cancelled for funding reasons. In the meantime, the instrument was used in a productive program of ground-based observing, which collected excellent scientific data and served as instrument tests. Given here is an overview of the history of the SOUP program, the scientific discoveries, and the instrument design and performance.

  4. Investigation of solar active regions at high resolution by balloon flights of the solar optical universal polarimeter, definition phase

    NASA Technical Reports Server (NTRS)

    Tarbell, Theodore D.; Topka, Kenneth P.

    1992-01-01

    The definition phase of a scientific study of active regions on the sun by balloon flight of a former Spacelab instrument, the Solar Optical Universal Polarimeter (SOUP) is described. SOUP is an optical telescope with image stabilization, tunable filter and various cameras. After the flight phase of the program was cancelled due to budgetary problems, scientific and engineering studies relevant to future balloon experiments of this type were completed. High resolution observations of the sun were obtained using SOUP components at the Swedish Solar Observatory in the Canary Islands. These were analyzed and published in studies of solar magnetic fields and active regions. In addition, testing of low-voltage piezoelectric transducers was performed, which showed they were appropriate for use in image stabilization on a balloon.

  5. A solar magnetic and velocity field measurement system for Spacelab 2: The solar optical universal polarimeter (SOUP)

    NASA Astrophysics Data System (ADS)

    Tarbell, Theodore D.; Title, Alan M.

    1992-08-01

    The Solar Optical Universal Polarimeter flew on the Shuttle Mission Spacelab 2 (STS-51F) in August, 1985, and collected historic solar observations. SOUP is the only solar telescope on either a spacecraft or balloon which has delivered long sequences of diffraction-limited images. These movies led to several discoveries about the solar atmosphere which were published in the scientific journals. After Spacelab 2, reflights were planned on the Space Shuttle Sunlab Mission, which was cancelled after the Challenger disaster, and on balloon flights, which were also cancelled for funding reasons. In the meantime, the instrument was used in a productive program of ground-based observing, which collected excellent scientific data and served as instrument tests. This report gives an overview of the history of the SOUP program, the scientific discoveries, and the instrument design and performance.

  6. View of the Challenger's payload bay and the SOUP experiment

    NASA Technical Reports Server (NTRS)

    1985-01-01

    The solar optical universal polarimeter (SOUP) experiment is visible among the cluster of Spacelab 2 hardware in the cargo bay of the Shuttle Challenger, backdropped against white clouds over ocean waters. Various components of the instrument positioning system (IPS) are conspicuous at the center of the frame. The remote manipulator system (RMS) arm is in its stowed position to the right of the frame.

  7. Correlation lifetimes of quiet and magnetic granulation from the SOUP instrument on Spacelab 2. [Solar Optical Universal Polarimeter

    NASA Technical Reports Server (NTRS)

    Title, A.; Tarbell, T.; Topka, K.; Acton, L.; Duncan, D.

    1988-01-01

    The time sequences of diffraction limited granulation images obtained by the Solar Optical Universal Polarimeter on Spacelab 2 are presented. The uncorrection autocorrelation limetime in magnetic regions is dominated by the 5-min oscillation. The removal of this oscillation causes the autocorrelation lifetime to increase by more than a factor of 2. The results suggest that a significant fraction of granule lifetimes are terminated by nearby explosions. Horizontal displacements and transverse velocities in the intensity field are measured. Lower limits to the lifetime in the quiet and magnetic sun are set at 440 s and 950 s, respectively.

  8. New Ideas About Granulation Based on Data from the Solar Optical Universal Polarimeter Instrument on Spacelab 2 and Magnetic Data from Big Bear Solar Observatory

    NASA Astrophysics Data System (ADS)

    Title, A. M.; Tarbell, T. D.; Topka, K. P.; Shine, R. A.; Simon, G. W.; Zirin, H.; SOUP Team

    The SOUP flow fields have been compared with carefully aligned magnetograms taken at the BBSO before, during, and after the SOUP images. The magnetic field is observed to exist in locations where either the flow is convergent or on the boundaries of the outflow from a flow cell center. Streamlines calculated from the flow field agree very well with the observed motions of the magnetic field in the BBSO magnetogram movies.

  9. White-light movies of the solar photosphere from the SOUP instrument on Spacelab. [Solar Optical Universal Polarimeter

    NASA Technical Reports Server (NTRS)

    Title, A. M.; Tarbell, T. D.; Acton, L; Duncan, D.; Simon, G. W.

    1986-01-01

    Initial results are presented on solar granulation, pores and sunspots from the white-light films obtained by the Solar Optical Universal Polarimeter (SOUP) instrument in Spacelab 2. Several hours of movies were taken at various disk and limb positions in quiet and active regions. The images are diffraction-limited at 0.5 arcsec resolution and are, of course, free of atmospheric seeing and distortion. Properties of the granulation in magnetic and nonmagnetic regions are compared and are found to differ significantly in size, rate of intensity variation, and lifetime. In quiet sun, on the order of fifty-percent of the area has at least one 'exploding granule' occurring in it during a 25-min period. Local correlation tracking has detected several types of transverse flows, including systematic outflow from the penumbral boundary of a spot, motion of penumbral filaments, and cellular flow patterns of supergranular and mesogranular size. Feature tracking has shown that, in the quiet sun, the average granule fragment has a velocity of about one kilometer/second.

  10. Investigation of solar active regions at high resolution by balloon flights of the solar optical universal polarimeter, extended definition phase

    NASA Technical Reports Server (NTRS)

    Tarbell, Theodore D.

    1993-01-01

    Technical studies of the feasibility of balloon flights of the former Spacelab instrument, the Solar Optical Universal Polarimeter, with a modern charge-coupled device (CCD) camera, to study the structure and evolution of solar active regions at high resolution, are reviewed. In particular, different CCD cameras were used at ground-based solar observatories with the SOUP filter, to evaluate their performance and collect high resolution images. High resolution movies of the photosphere and chromosphere were successfully obtained using four different CCD cameras. Some of this data was collected in coordinated observations with the Yohkoh satellite during May-July, 1992, and they are being analyzed scientifically along with simultaneous X-ray observations.

  11. View of the Challenger's payload bay and the Plasma Diagnostic package

    NASA Technical Reports Server (NTRS)

    1985-01-01

    The solar optical universal polarimeter (SOUP) experiment is visible among the cluster of Spacelab 2 hardware in the cargo bay of the Shuttle Challenger. Various components of the instrument positioning system (IPS) are conspicuous at the center of the frame. The Plasma Diagnostic package (PDP) is seen attached to the remote manipulator system (RMS) above the open payload bay.

  12. Investigation of active regions at high resolution by balloon flights of the Solar Optical Universal Polarimeter (SOUP)

    NASA Technical Reports Server (NTRS)

    Tarbell, T.; Frank, Z.; Gilbreth, C.; Shine, R.; Title, A.; Topka, K.; Wolfson, J.

    1989-01-01

    SOUP is a versatile, visible-light solar observatory, built for space or balloon flight. It is designed to study magnetic and velocity fields in the solar atmosphere with high spatial resolution and temporal uniformity, which cannot be achieved from the surface of the earth. The SOUP investigation is carried out by the Lockheed Palo Alto Research Laboratory, under contract to NASA's Marshall Space Flight Center. Co-investigators include staff members at a dozen observatories and universities in the U.S. and Europe. The primary objectives of the SOUP experiment are: to measure vector magnetic and velocity fields in the solar atmosphere with much better spatial resolution than can be achieved from the ground; to study the physical processes that store magnetic energy in active regions and the conditions that trigger its release; and to understand how magnetic flux emerges, evolves, combines, and disappears on spatial scales of 400 to 100,000 km. SOUP is designed to study intensity, magnetic, and velocity fields in the photosphere and low chromosphere with 0.5 arcsec resolution, free of atmospheric disturbances. The instrument includes: a 30 cm Cassegrain telescope; an active mirror for image stabilization; broadband film and TV cameras; a birefringent filter, tunable over 5100 to 6600 A with 0.05 A bandpass; a 35 mm film camera and a digital CCD camera behind the filter; and a high-speed digital image processor.

  13. Investigation of active regions at high resolution by balloon flights of the Solar Optical Universal Polarimeter (SOUP)

    NASA Astrophysics Data System (ADS)

    Tarbell, T.; Frank, Z.; Gilbreth, C.; Shine, R.; Title, A.; Topka, K.; Wolfson, J.

    SOUP is a versatile, visible-light solar observatory, built for space or balloon flight. It is designed to study magnetic and velocity fields in the solar atmosphere with high spatial resolution and temporal uniformity, which cannot be achieved from the surface of the earth. The SOUP investigation is carried out by the Lockheed Palo Alto Research Laboratory, under contract to NASA's Marshall Space Flight Center. Co-investigators include staff members at a dozen observatories and universities in the U.S. and Europe. The primary objectives of the SOUP experiment are: to measure vector magnetic and velocity fields in the solar atmosphere with much better spatial resolution than can be achieved from the ground; to study the physical processes that store magnetic energy in active regions and the conditions that trigger its release; and to understand how magnetic flux emerges, evolves, combines, and disappears on spatial scales of 400 to 100,000 km. SOUP is designed to study intensity, magnetic, and velocity fields in the photosphere and low chromosphere with 0.5 arcsec resolution, free of atmospheric disturbances. The instrument includes: a 30 cm Cassegrain telescope; an active mirror for image stabilization; broadband film and TV cameras; a birefringent filter, tunable over 5100 to 6600 A with 0.05 A bandpass; a 35 mm film camera and a digital CCD camera behind the filter; and a high-speed digital image processor.

  14. View of Spacelab 2 pallet in the open payload bay

    NASA Image and Video Library

    1985-07-29

    51F-33-005 (29 July - 6 August 1985) --- Experiments and the instrument pointing system (IPS) for Spacelab 2 are backdropped against the Libya/Tunisia Mediterranean coast and black space in this 70mm view photographed through the aft flight deck windows of the Space Shuttle Challenger. Also partially visible among the cluster of Spacelab 2 hardware are the solar optical universal polarimeter (SOUP) experiment and the coronal helium abundance experiment (CHASE).

  15. Video image processor on the Spacelab 2 Solar Optical Universal Polarimeter /SL2 SOUP/

    NASA Technical Reports Server (NTRS)

    Lindgren, R. W.; Tarbell, T. D.

    1981-01-01

    The SOUP instrument is designed to obtain diffraction-limited digital images of the sun with high photometric accuracy. The Video Processor originated from the requirement to provide onboard real-time image processing, both to reduce the telemetry rate and to provide meaningful video displays of scientific data to the payload crew. This original concept has evolved into a versatile digital processing system with a multitude of other uses in the SOUP program. The central element in the Video Processor design is a 16-bit central processing unit based on 2900 family bipolar bit-slice devices. All arithmetic, logical and I/O operations are under control of microprograms, stored in programmable read-only memory and initiated by commands from the LSI-11. Several functions of the Video Processor are described, including interface to the High Rate Multiplexer downlink, cosmetic and scientific data processing, scan conversion for crew displays, focus and exposure testing, and use as ground support equipment.

  16. On the relation between photospheric flow fields and the magnetic field distribution on the solar surface

    NASA Technical Reports Server (NTRS)

    Simon, George W.; Title, A. M.; Topka, K. P.; Tarbell, T. D.; Shine, R. A.

    1988-01-01

    Using the technique of local correlation tracking on a 28 minute time sequence of white-light images of solar granulation, the horizontal flow field on the solar surface is measured. The time series was obtained by the Solar Optical Universal Polarimeter (SOUP) on Spacelab 2 (Space Shuttle flight 51-F) and is free from atmospheric blurring and distortion. The SOUP flow fields have been compared with carefully aligned magnetograms taken over a nine hour period at the Big Bear Solar Observatory before, during, and after the SOUP images. The flow field and the magnetic field agree in considerable detail: vectors which define the flow of the white-light intensity pattern (granulation) point toward magnetic field regions, magnetic fields surround flow cells, and magnetic features move along the flow arrows. The projected locations of free particles ('corks') in the measured flow field congregate at the same locations where the magnetic field is observed.

  17. Statistical properties of solar granulation derived from the SOUP instrument on Spacelab 2

    NASA Technical Reports Server (NTRS)

    Title, A. M.; Tarbell, T. D.; Topka, K. P.; Ferguson, S. H.; Shine, R. A.

    1989-01-01

    Computer algorithms and statistical techniques were used to identify, measure, and quantify the properties of solar granulation derived from movies collected by the Solar Optical Universal Polarimeter on Spacelab 2. The results show that there is neither a typical solar granule nor a typical granule evolution. A granule's evolution is dependent on local magnetic flux density, its position with respect to the active region plage, its position in the mesogranulation pattern, and the evolution of granules in its immediate neighborhood.

  18. High resolution observations: The state of the art and beyond

    NASA Technical Reports Server (NTRS)

    Title, A.; Tarbell, T.; Shine, R.; Topka, K.; Frank, Z.

    1992-01-01

    The meaning of high resolution and its scientific importance with regard to solar observations is discussed. The state of the art is reviewed, looking into Solar Optical Universal Polarimeter (SOUP) observations, image selection techniques, and adaptive optics. It is concluded that until there are observations in space, complete understanding of processes in the solar photosphere, chromosphere, transition region, and corona will be impossible. The importance of high resolution is considered with regard to solar surface and convection, solar photosphere inside and outside magnetic fields, and sunspot geometry.

  19. Image motion compensation on the Spacelab 2 Solar Optical Universal Polarimeter /SL2 SOUP/

    NASA Technical Reports Server (NTRS)

    Tarbell, T. D.; Duncan, D. W.; Finch, M. L.; Spence, G.

    1981-01-01

    The SOUP experiment on Spacelab 2 includes a 30 cm visible light telescope and focal plane package mounted on the Instrument Pointing System (IPS). Scientific goals of the experiment dictate pointing stability requirements of less than 0.05 arcsecond jitter over periods of 5-20 seconds. Quantitative derivations of these requirements from two different aspects are presented: (1) avoidance of motion blurring of diffraction-limited images; (2) precise coalignment of consecutive frames to allow measurement of small image differences. To achieve this stability, a fine guider system capable of removing residual jitter of the IPS and image motions generated on the IPS cruciform instrument support structure has been constructed. This system uses solar limb detectors in the prime focal plane to derive an error signal. Image motion due to pointing errors is compensated by the agile secondary mirror mounted on piezoelectric transducers, controlled by a closed-loop servo system.

  20. Correlation lifetimes of quiet and magnetic granulation from the SOUP instrument on Spacelab 2

    NASA Astrophysics Data System (ADS)

    Title, A.; Tarbell, T.; Topka, K.; Acton, L.; Duncan, D.; Ferguson, S.; Finch, M.; Frank, Z.; Kelly, G.; Lindgren, R.; Morrill, M.; Pope, T.; Reeves, R.; Rehse, R.; Shine, R.; Simon, G.; Harvey, J.; Leibacher, J.; Livingston, W.; November, L.; Zirker, J.

    The time sequences of diffraction limited granulation images obtained by the Solar Optical Universal Polarimeter on Spacelab 2 are presented. The uncorrection autocorrelation limetime in magnetic regions is dominated by the 5-min oscillation. The removal of this oscillation causes the autocorrelation lifetime to increase by more than a factor of 2. The results suggest that a significant fraction of granule lifetimes are terminated by nearby explosions. Horizontal displacements and transverse velocities in the intensity field are measured. Lower limits to the lifetime in the quiet and magnetic sun are set at 440 s and 950 s, respectively.

  1. First results on quiet and magnetic granulation from SOUP

    NASA Technical Reports Server (NTRS)

    Title, A. M.; Tarbell, T. D.; Acton, L.; Duncan, D.; Ferguson, S. H.; Finch, M.; Frank, Z.; Kelly, G.; Lindgren, R.; Morrill, M.

    1987-01-01

    The flight of Solar Optical Universal Polarimeter (SOUP) on Spacelab 2 allowed the collection of time sequences of diffraction limited (0.5 arc sec) granulation images with excellent pointing (0.003 arc sec) and completely free of the distortion that plagues groundbased images. The p-mode oscillations are clearly seen in the data. Using Fourier transforms in the temporal and spatial domain, it was shown that the p-modes dominate the autocorrelation lifetime in magnetic regions. When these oscillations are removed the autocorrelation lifetime is found to be 500 sec in quiet and 950 sec in magnetic regions. In quiet areas exploding granules are seen to be common. It is speculated that a significant fraction of granule lifetimes are terminated by nearby explosions. Using local correlation tracking techniques it was able to measure horizontal displacements, and thus transverse velocities, in the magnetic field. In quiet sun it is possible to detect both super and mesogranulation. Horizontal velocities are as great as 1000 m/s and the average velocity is 400 m/s. In magnetic regions horizontal velocities are much less, about 100 m/s.

  2. First results on quiet and magnetic granulation from SOUP

    NASA Astrophysics Data System (ADS)

    Title, A. M.; Tarbell, T. D.; Acton, L.; Duncan, D.; Ferguson, S. H.; Finch, M.; Frank, Z.; Kelly, G.; Lindgren, R.; Morrill, M.

    1987-09-01

    The flight of Solar Optical Universal Polarimeter (SOUP) on Spacelab 2 allowed the collection of time sequences of diffraction limited (0.5 arc sec) granulation images with excellent pointing (0.003 arc sec) and completely free of the distortion that plagues groundbased images. The p-mode oscillations are clearly seen in the data. Using Fourier transforms in the temporal and spatial domain, it was shown that the p-modes dominate the autocorrelation lifetime in magnetic regions. When these oscillations are removed the autocorrelation lifetime is found to be 500 sec in quiet and 950 sec in magnetic regions. In quiet areas exploding granules are seen to be common. It is speculated that a significant fraction of granule lifetimes are terminated by nearby explosions. Using local correlation tracking techniques it was able to measure horizontal displacements, and thus transverse velocities, in the magnetic field. In quiet sun it is possible to detect both super and mesogranulation. Horizontal velocities are as great as 1000 m/s and the average velocity is 400 m/s. In magnetic regions horizontal velocities are much less, about 100 m/s.

  3. Statistical properties of solar granulation from the SOUP instrument on Spacelab 2

    NASA Astrophysics Data System (ADS)

    Topka, K.; Title, A.; Tarbell, T.; Ferguson, S.; Shine, R.

    1988-11-01

    The Solar Optical Universal Polarimeter (SOUP) on Spacelab 2 collected movies of solar granulation completely free from atmospheric blurring, and are not degraded by pointint jitter (the pointing stability was 0.003 sec root mean square). The movies illustrate that the solar five minute oscillation has a major role in the appearance of solar granulation and that exploding granules are a common feature of the granule evolution. Using 3-D Fourier filtering techniques the oscillations were removed and it was demonstrated that the autocorrelation lifetime of granulation is a factor of two greater in magnetic field regions than in field-free quiet sun. Horizontal velocities were measured and flow patterns were observed on the scale of meso- and super granulation. In quiet regions the mean flow velocity is 370 m/s while in the magnetic regions it is about 125 m/s. It was also found that the root mean square (RMS) fluctuating horizonal velocity field is substantially greater in quiet sun than in strong magnetic field regions. By superimposing the location of exploding granules on the average flow maps it was found that they appear almost exclusively in the center of mesogranulation size flow cells. Because of the nonuniformity of the distribution of exploding granules, the evolution of the granulation pattern in mesogranule cell centers and boundaries differs fundamentally. It is clear from this study there is neither a typical granule nor a typical granule evolution.

  4. Statistical properties of solar granulation from the SOUP instrument on Spacelab 2

    NASA Technical Reports Server (NTRS)

    Topka, K.; Title, A.; Tarbell, T.; Ferguson, S.; Shine, R.

    1988-01-01

    The Solar Optical Universal Polarimeter (SOUP) on Spacelab 2 collected movies of solar granulation completely free from atmospheric blurring, and are not degraded by pointint jitter (the pointing stability was 0.003 sec root mean square). The movies illustrate that the solar five minute oscillation has a major role in the appearance of solar granulation and that exploding granules are a common feature of the granule evolution. Using 3-D Fourier filtering techniques the oscillations were removed and it was demonstrated that the autocorrelation lifetime of granulation is a factor of two greater in magnetic field regions than in field-free quiet sun. Horizontal velocities were measured and flow patterns were observed on the scale of meso- and super granulation. In quiet regions the mean flow velocity is 370 m/s while in the magnetic regions it is about 125 m/s. It was also found that the root mean square (RMS) fluctuating horizonal velocity field is substantially greater in quiet sun than in strong magnetic field regions. By superimposing the location of exploding granules on the average flow maps it was found that they appear almost exclusively in the center of mesogranulation size flow cells. Because of the nonuniformity of the distribution of exploding granules, the evolution of the granulation pattern in mesogranule cell centers and boundaries differs fundamentally. It is clear from this study there is neither a typical granule nor a typical granule evolution.

  5. First results from Spacelab 2

    NASA Technical Reports Server (NTRS)

    Urban, E. W.

    1986-01-01

    Preliminary results of physical experiments carried out during the Spacelab 2 Shuttle mission are summarized. Attention is given to experiments in the fields of plasma dynamics; solar physics; high-energy astrophysics; and astronomy. Plasma experiments included an ejectable plasma diagnosics package and measurements of the passive charging of the Shuttle vehicle in the surrounding space plasma. The solar physics instrument package consisted of a solar spectral irradiance monitor; a solar optical universal polarimeter (SOUP); and a solar helium abundance high-resolution telescope and spectrograph (HRTS). Astronomical observations were performed using a scanning infrared telescope (IRT) which consisted of a highly baffled herschelian telescope and 10 detectors covering wavelengths from 2 to 120 microns. Cosmic-ray nuclei were detected and analyzed using gas Cerenkov counters and a transition radiation detector. Addition experiments included a thin film fluid dynamics payload and analysis of blood samples taken from the mission specialists. Complete data records from the experiments have now been distributed for an analysis period which will take at least a year. A table listing the Spacelab 2 experiments and their principal investigators is provided.

  6. Stone Soup Partnership: A Grassroots Model of Community Service.

    ERIC Educational Resources Information Center

    Kittredge, Robert E.

    1997-01-01

    Stone Soup Partnership is a collaboration between California State University at Fresno and its surrounding community to address serious problems in a high-crime, impoverished apartment complex near the university. The program involves students in service learning for university credit, and has expanded from a single summer youth program to a…

  7. The test of the layout of polarimeter "UFP" on the telescope AZT-2

    NASA Astrophysics Data System (ADS)

    Levchenko, T. A.; Nevodovskyi, P. V.; Vidmachenko, A. P.; Morozhenko, O. V.; Saryboha, H. V.; Zbrutsky, O. V.; Ivakhiv, O. V.

    2016-05-01

    Main Astronomical Observatory of NAS of Ukraine in cooperation with the National Technical University of Ukraine "KPI" and National University "Lviv Polytechnic" for a long time working on the design of an optical polarimeter to study of the stratospheric layer of the Earth using of orbital satellite. During this time, was accumulated a large experience of such work, and was established a layout of compact ultraviolet polarimeter (UFP) on board of satellite

  8. LWIR Microgrid Polarimeter for Remote Sensing Studies

    DTIC Science & Technology

    2010-02-28

    Polarimeter for Remote Sensing Studies 5b. GRANT NUMBER FA9550-08-1-0295 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 1. Scott Tyo 5e. TASK...and tested at the University of Arizona, and preliminary images are shown in this final report. 15. SUBJECT TERMS Remote Sensing , polarimetry 16...7.0 LWIR Microgrid Polarimeter for Remote Sensing Studies J. Scott Tyo College of Optical Sciences University of Arizona Tucson, AZ, 85721 tyo

  9. Performance of the PRAXyS X-Ray Polarimeter

    NASA Technical Reports Server (NTRS)

    Iwakiri, W. B.; Black, J. K.; Cole, R.; Enoto, T.; Hayato, A.; Hill, J. E.; Jahoda, Keith M.; Kaaret, P.; Kitaguchi, T.; Kubota, M.

    2016-01-01

    The performance of the Time Projection Chamber (TPC) polarimeter for the Polarimeter for Relativistic Astrophysical X-ray Sources (PRAXyS) Small Explorer was evaluated using polarized and unpolarized X-ray sources. The PRAXyS mission will enable exploration of the universe through X-ray polarimetry in the 2-10 keV energy band. We carried out performance tests of the polarimeter at the Brookhaven National Laboratory, National Synchrotron Light Source (BNL-NSLS) and at NASA's Goddard Space Flight Center. The polarimeter was tested with linearly polarized, monochromatic X-rays at 11 different energies between 2.5 and 8.0 keV. At maximum sensitivity, the measured modulation factors at 2.7, 4.5 and 8.0 keV are 27%, 43% and 59%, respectively and the measured angle of polarization is consistent with the expected value at all energies. Measurements with a broadband, unpolarized X-ray source placed a limit of less than 1% on false polarization in the PRAXyS polarimeter.

  10. Performance of the PRAXyS X-ray polarimeter

    NASA Astrophysics Data System (ADS)

    Iwakiri, W. B.; Black, J. K.; Cole, R.; Enoto, T.; Hayato, A.; Hill, J. E.; Jahoda, K.; Kaaret, P.; Kitaguchi, T.; Kubota, M.; Marlowe, H.; McCurdy, R.; Takeuchi, Y.; Tamagawa, T.

    2016-12-01

    The performance of the Time Projection Chamber (TPC) polarimeter for the Polarimeter for Relativistic Astrophysical X-ray Sources (PRAXyS) Small Explorer was evaluated using polarized and unpolarized X-ray sources. The PRAXyS mission will enable exploration of the universe through X-ray polarimetry in the 2-10 keV energy band. We carried out performance tests of the polarimeter at the Brookhaven National Laboratory, National Synchrotron Light Source (BNL-NSLS) and at NASA's Goddard Space Flight Center. The polarimeter was tested with linearly polarized, monochromatic X-rays at 11 different energies between 2.5 and 8.0 keV. At maximum sensitivity, the measured modulation factors at 2.7, 4.5 and 8.0 keV are 27%, 43% and 59%, respectively and the measured angle of polarization is consistent with the expected value at all energies. Measurements with a broadband, unpolarized X-ray source placed a limit of less than 1% on false polarization in the PRAXyS polarimeter.

  11. Inflation Due to Quantum Potential

    NASA Astrophysics Data System (ADS)

    Eingorn, Maxim V.; Rusov, Vitaliy D.

    2015-08-01

    In the framework of a cosmological model of the Universe filled with a nonrelativistic particle soup, we easily reproduce inflation due to the quantum potential. The lightest particles in the soup serve as a driving force of this simple, natural and promising mechanism. It is explicitly demonstrated that the appropriate choice of their mass and fraction leads to reasonable numbers of e-folds. Thus, the direct introduction of the quantum potential into cosmology of the earliest Universe gives ample opportunities of successful reconsideration of the modern inflationary theory.

  12. Concerning the use of multifunctional photometer - polarimeter for studying the invasion of cosmic bodies into the Earth's atmosphere

    NASA Astrophysics Data System (ADS)

    Geraimchuk, M. D.; Vidmachenko, A. P.; Nevodovskyi, P. V.; Steklov, O. F.

    2018-05-01

    Main astronomical observatory of the National Academy of Sciences of Ukraine together with the National Technical University of Ukraine "KPI" for many years working on the development of photometers-polarimeters for the study of cosmic bodies and Earth's atmosphere. We proposed an option of the development of a multipurpose panoramic photometer-polarimeter, which takes into account the shortcomings of the previous versions of the instrument and also allows for the registration of tracks of bolides, and study of their tails, and weak meteor phenomena.

  13. The Polarimeter for Relativistic Astrophysical X-ray Sources

    NASA Astrophysics Data System (ADS)

    Jahoda, Keith; Kallman, Timothy R.; Kouveliotou, Chryssa; Angelini, Lorella; Black, J. Kevin; Hill, Joanne E.; Jaeger, Theodore; Kaaret, Philip E.; Markwardt, Craig B.; Okajima, Takashi; Petre, Robert; Schnittman, Jeremy; Soong, Yang; Strohmayer, Tod E.; Tamagawa, Toru; Tawara, Yuzuru

    2016-07-01

    The Polarimeter for Relativistic Astrophysical X-ray Sources (PRAXyS) is one of three Small Explorer (SMEX) missions selected by NASA for Phase A study, with a launch date in 2020. The PRAXyS Observatory exploits grazing incidence X-ray mirrors and Time Projection Chamber Polarimeters capable of measuring the linear polarization of cosmic X-ray sources in the 2-10 keV band. PRAXyS combines well-characterized instruments with spacecraft rotation to ensure low systematic errors. The PRAXyS payload is developed at the Goddard Space Flight Center with the Johns Hopkins University Applied Physics Laboratory, University of Iowa, and RIKEN (JAXA) collaborating on the Polarimeter Assembly. The LEOStar-2 spacecraft bus is developed by Orbital ATK, which also supplies the extendable optical bench that enables the Observatory to be compatible with a Pegasus class launch vehicle. A nine month primary mission will provide sensitive observations of multiple black hole and neutron star sources, where theory predicts polarization is a strong diagnostic, as well as exploratory observations of other high energy sources. The primary mission data will be released to the community rapidly and a Guest Observer extended mission will be vigorously proposed.

  14. Microstates of black holes in expanding universe from interacting branes

    NASA Astrophysics Data System (ADS)

    Shiba, Shotaro

    2017-05-01

    Thermodynamics of the near extremal black p-branes can be described by collective motions of gravitationally interacting branes. This proposal is called the p-soup model. In this paper, we check this proposal in the case of black brane system which is asymptotically Friedmann-Lemaître-Robertson-Walker universe in an infinite distance. As a result, we can show that the gravitationally interacting branes explain free energy, entropy, temperature and other physical quantities in these systems. This implies that the microstates of this kind of brane system can be also understood in the p-soup model.

  15. A Disconnect between Staff and Student Perceptions of Learning: An ACELL Educational Analysis of the First Year Undergraduate Chemistry Experiment "Investigating Sugar Using a Home Made Polarimeter"

    ERIC Educational Resources Information Center

    Crisp, Michael G.; Kable, Scott H.; Read, Justin R.; Buntine, Mark A.

    2011-01-01

    This paper describes an educational analysis of a first year university chemistry practical called "Investigating sugar using a home made polarimeter". The analysis follows the formalism of the Advancing Chemistry by Enhancing Learning in the Laboratory (ACELL) project, which includes a statement of education objectives, and an analysis…

  16. A Burst Chasing X-ray Polarimeter

    NASA Technical Reports Server (NTRS)

    Hill, Joanne; Hill, Joe; Barthelmy, S.; Black, K.; Deines-Jones, P.; Jahoda, K.; Sakamoto, T.; Kaaret, P.; McConnell, M.; Bloser, P.; hide

    2007-01-01

    Tihs is a viewgraph presentation of a discussion of the X-ray Polarimeter. Gamma-ray bursts are one of the most powerful explosions in the universe and have been detected out to distances of almost 13 billion light years. The exact origin of these energetic explosions is still unknown but the resulting huge release of energy is thought to create a highly relativistic jet of material and a power-law distribution of electrons. There are several theories describing the origin of the prompt GRB emission that currently cannot be distinguished. Measurements of the linear polarization would provide unique and important constraints on the mechanisms thought to drive these powerful explosions. We present the design of a sensitive, and extremely versatile gamma-ray burst polarimeter. The instrument is a photoelectric polarimeter based on a time-projection chamber. The photoelectric time-projection technique combines high sensitivity with broad band-pass and is potentially the most powerful method between 2 and 100 keV where the photoelectric effect is the dominant interaction process We present measurements of polarized and unpolarized X-rays obtained with a prototype detector and describe the two mission concepts, the Gamma-Ray Burst Polarimeter (GRBP) for thc U S Naval Academy satellite MidSTAR-2, and thc Low Energy Polarimeter (LEP) onboard POET, a broadband polarimetry concept for a small explorer mission.

  17. Development of a Hydrogen Møller Polarimeter for Precision Parity-Violating Electron Scattering

    NASA Astrophysics Data System (ADS)

    Gray, Valerie M.

    2013-10-01

    Parity-violating electron scattering experiments allow for testing the Standard Model at low energy accelerators. Future parity-violating electron scattering experiments, like the P2 experiment at the Johannes Gutenberg University, Mainz, Germany, and the MOLLER and SoLID experiments at Jefferson Lab will measure observables predicted by the Standard Model to high precision. In order to make these measurements, we will need to determine the polarization of the electron beam to sub-percent precision. The present way of measuring the polarization, with Møller scattering in iron foils or using Compton laser backscattering, will not easily be able to reach this precision. The novel Hydrogen Møller Polarimeter presents a non-invasive way to measure the electron polarization by scattering the electron beam off of atomic hydrogen gas polarized in a 7 Tesla solenoidal magnetic trap. This apparatus is expected to be operational by 2016 in Mainz. Currently, simulations of the polarimeter are used to develop the detection system at College of William & Mary, while the hydrogen trap and superconducting solenoid magnet are being developed at the Johannes Gutenberg University, Mainz. I will discuss the progress of the design and development of this novel polarimeter system. This material is based upon work supported by the National Science Foundation under Grant No. PHY-1206053.

  18. Hyperspectral imaging polarimeter in the infrared

    NASA Astrophysics Data System (ADS)

    Jensen, Gary L.; Peterson, James Q.

    1998-11-01

    The Space Dynamics Laboratory at Utah State University is building an infrared Hyperspectral Imaging Polarimeter (HIP). Designed for high spatial and spectral resolution polarimetry of backscattered sunlight from cloud tops in the 2.7 micrometer water band, it will fly aboard the Flying Infrared Signatures Technology Aircraft (FISTA), an Air Force KC-135. It is a proof-of-concept sensor, combining hyperspectral pushbroom imaging with high speed, solid state polarimetry, using as many off-the-shelf components as possible, and utilizing an optical breadboard design for rapid prototyping. It is based around a 256 X 320 window selectable InSb camera, a solid-state Ferro-electric Liquid Crystal (FLC) polarimeter, and a transmissive diffraction grating.

  19. Deep 'Stone Soup' Trenching by Phoenix

    NASA Technical Reports Server (NTRS)

    2008-01-01

    Digging by NASA's Phoenix Mars Lander on Aug. 23, 2008, during the 88th sol (Martian day) since landing, reached a depth about three times greater than in any trench Phoenix has excavated. The deep trench, informally called 'Stone Soup' is at the borderline between two of the polygon-shaped hummocks that characterize the arctic plain where Phoenix landed.

    The lander's Surface Stereo Imager took this picture of Stone Soup trench on Sol 88 after the day's digging. The trench is about 25 centimeters (10 inches) wide and about 18 centimeters (7 inches) deep.

    When digging trenches near polygon centers, Phoenix has hit a layer of icy soil, as hard as concrete, about 5 centimeters or 2 inches beneath the ground surface. In the Stone Soup trench at a polygon margin, the digging has not yet hit an icy layer like that.

    Stone Soup is toward the left, or west, end of the robotic arm's work area on the north side of the lander.

    The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  20. The Absolute Spectrum Polarimeter (ASP)

    NASA Technical Reports Server (NTRS)

    Kogut, A. J.

    2010-01-01

    The Absolute Spectrum Polarimeter (ASP) is an Explorer-class mission to map the absolute intensity and linear polarization of the cosmic microwave background and diffuse astrophysical foregrounds over the full sky from 30 GHz to 5 THz. The principal science goal is the detection and characterization of linear polarization from an inflationary epoch in the early universe, with tensor-to-scalar ratio r much greater than 1O(raised to the power of { -3}) and Compton distortion y < 10 (raised to the power of{-6}). We describe the ASP instrument and mission architecture needed to detect the signature of an inflationary epoch in the early universe using only 4 semiconductor bolometers.

  1. A Cryogenic Half-Wave Plate Module to Measure Polarization at Multiple FIR Passbands

    NASA Technical Reports Server (NTRS)

    Rennick, Timothy S.; Vaillancourt, John E.; Hildebrand, Roger H.; Heimsath, Stephen J.

    2002-01-01

    One of the key components in a far-infrared polarimeter that is being designed at the University of Chicago is a locally-powered half-wave plate module. This compact, lightweight, and reliable module will operate at cryogenic temperatures, rotating a half-wave plate about its axis within the optical path. By doing so, polarization measurements can be made. Further, by utilizing multiple half-wave plate modules within the polarimeter, multiple wavelengths or passbands can be studied. In this paper, we describe the design and performance of a relatively inexpensive prototype module that was assembled and tested successfully, outline the difficulties that had to be overcome, and recommend improvements to future modules. This effort now lays some of the groundwork for a next-generation polarimeter for far-infrared astronomy.

  2. A burst chasing x-ray polarimeter

    NASA Astrophysics Data System (ADS)

    Hill, Joanne E.; Barthelmy, Scott; Black, J. Kevin; Deines-Jones, Philip; Jahoda, Keith; Sakamoto, Takanori; Kaaret, Philip; McConnell, Mark L.; Bloser, Peter F.; Macri, John R.; Legere, Jason S.; Ryan, James M.; Smith, Billy R., Jr.; Zhang, Bing

    2007-09-01

    Gamma-ray bursts are one of the most powerful explosions in the universe and have been detected out to distances of almost 13 billion light years. The exact origin of these energetic explosions is still unknown but the resulting huge release of energy is thought to create a highly relativistic jet of material and a power-law distribution of electrons. There are several theories describing the origin of the prompt GRB emission that currently cannot be distinguished. Measurements of the linear polarization would provide unique and important constraints on the mechanisms thought to drive these powerful explosions. We present the design of a sensitive, and extremely versatile gamma-ray burst polarimeter. The instrument is a photoelectric polarimeter based on a time-projection chamber. The photoelectric time-projection technique combines high sensitivity with broad band-pass and is potentially the most powerful method between 2 and 100 keV where the photoelectric effect is the dominant interaction process. We present measurements of polarized and unpolarized X-rays obtained with a prototype detector and describe the two mission concepts; the Gamma-Ray Burst Polarimeter (GRBP) for the U.S. Naval Academy satellite MidSTAR-2, and the Low Energy Polarimeter (LEP) onboard POET, a broadband polarimetry concept for a small explorer mission.

  3. A Burst Chasing X-ray Polarimeter

    NASA Technical Reports Server (NTRS)

    Hill, Joanne E.; Barthelmy, Scott; Black, J. kevin; Deines-Jones, Philip; Jahoda, Keith; Sakamoto, Takanori; Kaaret, Philip; McConnell, Mark L.; Bloser, Peter F.; Macri, John R.; hide

    2007-01-01

    Gamma-ray bursts are one of the most powerful explosions in the universe and have been detected out to distances of almost 13 billion light years. The exact origin of these energetic explosions is still unknown but the resulting huge release of energy is thought to create a highly relativistic jet of material and a power-law distribution of electrons. There are several theories describing the origin of the prompt GRB emission that currently cannot be distinguished. Measurements of the linear polarization would provide unique and important constraints on the mechanisms thought to drive these powerful explosions. We present the design of a sensitive, and extremely versatile gamma-ray burst polarimeter. The instrument is a photoelectric polarimeter based on a time-projection chamber. The photoelectric time-projection technique combines high sensitivity with broad band-pass and is potentially the most powerful method between 2 and 100 keV where the photoelectric effect 1s the dominant interaction process We present measurements of polarized and unpolarized X-rays obtained with a prototype detector and describe the two mission concepts, the Gamma-Ray Burst Polarimeter (GRBP) for thc U S Naval Academy satellite MidSTAR-2, and thc Low Energy Polarimeter (LEP) onboard POET, a broadband polarimetry concept for a small explorer mission.

  4. A recipe for primordial soup

    NASA Technical Reports Server (NTRS)

    Kolb, E.

    2001-01-01

    If the universe emerged from a state of high temperature and high density, we can study the origin of the universe by recreating those conditions in the laboratory. While we can not reproduce the Big Bang, we can recreate its conditions and study the physical processes responsible for producing the rich and varied universe we observe today.

  5. Connecting QGP-Heavy Ion Physics to the Early Universe

    NASA Astrophysics Data System (ADS)

    Rafelski, Johann

    2013-10-01

    We discuss properties and evolution of quark-gluon plasma in the early Universe and compare to laboratory heavy ion experiments. We describe how matter and antimatter emerged from a primordial soup of quarks and gluons. We focus our discussion on similarities and differences between the early Universe and the laboratory experiments.

  6. GDx-MM: An imaging Mueller matrix retinal polarimeter

    NASA Astrophysics Data System (ADS)

    Twietmeyer, Karen Marie

    2007-12-01

    Retinal diseases are a major cause of blindness worldwide. Although widely studied, disease mechanisms are not completely understood, and diagnostic tests may not detect disease early enough for timely intervention. The goal of this research is to contribute to research for more sensitive diagnostic tests that might use the interaction of polarized light with retinal tissue to detect subtle changes in the microstructure. This dissertation describes the GDx-MM, a scanning laser polarimeter which measures a complete 16-element Mueller matrix image of the retina. This full polarization signature may provide new comparative information on the structure of healthy and diseased retinal tissue by highlighting depolarizing structures as well as structures with varying magnitudes and orientations of retardance and diattenuation. The three major components of this dissertation are: (1) Development of methods for polarimeter optimization and error analysis; (2) Design, optimization, assembly, calibration, and validation of the GDx-MM polarimeter; and (3) Analysis of data for several human subjects. Development involved modifications to a Laser Diagnostics GDx, a commercially available scanning laser ophthalmoscope with incomplete polarization capability. Modifications included installation of polarization components, development of a data acquisition system, and implementation of algorithms to convert raw data into polarization parameter images. Optimization involved visualization of polarimeter state trajectories on the Poincare sphere and a condition number analysis of the instrument matrix. Retinal images are collected non-invasively at 20 mum resolution over a 15° visual field in four seconds. Validation of the polarimeter demonstrates a polarimetric measurement accuracy of approximately +/- 5%. Retinal polarization data was collected on normal human subjects at the University of Arizona and at Indiana University School of Optometry. Calculated polarization parameter images reveal properties of the tissue microstructure. For example, retardance images indicate nerve fiber layer thickness and orientation, and depolarization images (uniform for these normal subjects), are predicted to indicate regions of disease-related tissue disruption. This research demonstrates a method for obtaining a full polarization signature of the retina in one measurement using a polarimetrically optimized instrument, and provides a step toward the use of complete retinal imaging polarimetry in the diagnosis and monitoring of retinal disease.

  7. Deep 'Stone Soup' Trenching by Phoenix (Stereo)

    NASA Technical Reports Server (NTRS)

    2008-01-01

    Digging by NASA's Phoenix Mars Lander on Aug. 23, 2008, during the 88th sol (Martian day) since landing, reached a depth about three times greater than in any trench Phoenix has excavated. The deep trench, informally called 'Stone Soup' is at the borderline between two of the polygon-shaped hummocks that characterize the arctic plain where Phoenix landed.

    Stone Soup is in the center foreground of this stereo view, which appears three dimensional when seen through red-blue glasses. The view combines left-eye and right-eye images taken by the lander's Surface Stereo Imager on Sol 88 after the day's digging. The trench is about 25 centimeters (10 inches) wide and about 18 centimeters (7 inches) deep.

    When digging trenches near polygon centers, Phoenix has hit a layer of icy soil, as hard as concrete, about 5 centimeters or 2 inches beneath the ground surface. In the Stone Soup trench at a polygon margin, the digging has not yet hit an icy layer like that.

    Stone Soup is toward the left, or west, end of the robotic arm's work area on the north side of the lander.

    The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  8. Experimental Evaluation of the Flight Line Food Service Facility at Travis AFB

    DTIC Science & Technology

    1974-06-01

    8217emm^^mmi - TABLE 1 DINNER MENU SOUPS DAILY Chili Con Came, Chicken Noodle Soup, Vegetable Soup, Cream of Tomato Soup MON - Vegetable-Beef...Soup TUE - Cream of Chicken Soup WED - Minestrone Soup THU - Beef Noodle Soup FRI - Clam Chowder SAT - Chicken Rice Soup SUN...within two days; frozen sandwiches and breakfast meals would be manufactured once a week and dinner meals every two weeks. During the experiment

  9. Results from the First Two Observing Seasons of PIQUE

    NASA Astrophysics Data System (ADS)

    Gundersen, Joshua; Barkats, Denis; Hedman, Matt; Staggs, Suzanne; Winstein, Bruce

    2001-04-01

    We report on the first two seasons of the Princeton IQU Experiment (PIQUE). PIQUE is a ground-based telescope designed to measure the polarization of the Cosmic Microwave Background (CMB). During the first season (1/19/00-4/2/00), PIQUE measured the Q Stokes parameter on a ring at declination of 89 degrees from the roof of the Physics Department at Princeton University using a 90 GHz correlation polarimeter with a full-width-half maximum beam of 0.24 degrees. PIQUE's observations from the first season yielded a new limit on the polarization of the CMB in the multipole range 100

  10. The Bragg Reflection Polarimeter On the Gravity and Extreme Magnetism Small Explorer Mission

    NASA Astrophysics Data System (ADS)

    Allured, Ryan; Griffiths, S.; Daly, R.; Prieskorn, Z.; Marlowe, H.; Kaaret, P.; GEMS Team

    2011-09-01

    The strong gravity associated with black holes warps the spacetime outside of the event horizon, and it is predicted that this will leave characteristic signatures on the polarization of X-ray emission originating in the accretion disk. The Gravity and Extreme Magnetism Small Explorer (GEMS) mission will be the first observatory with the capability to make polarization measurements with enough sensitivity to quantitatively test this prediction. Students at the University of Iowa are currently working on the development of the Bragg Reflection Polarimeter (BRP), a soft X-ray polarimeter sensitive at 500 eV, that is the student experiment on GEMS. The BRP will complement the main experiment by making a polarization measurement from accreting black holes below the main energy band (2-10 keV). This measurement will constrain the inclination of the accretion disk and tighten measurements of black hole spin.

  11. How Can the U.S. Military Avoid Another 9/15?: An Analysis of the Inability of U.S. Military Leaders to Provide an Adequate Strategy for Responding to the 9/11 Attacks

    DTIC Science & Technology

    2007-12-01

    Deputy Chief of Staff for Operations and Plans, Department of the Army (DSCOPS, DA). d. Conduct programs which bear directly on the Army in the field...response recommendation were all products of an educational system that focused on a Direct Approach. In his work, Learning to Eat Soup with a...79 Duggan, p 169. 80 John Nagl, Learning to Eat Soup with a Knife: Counterinsurgency Lessons from Malaya and Vietnam, Chicago: University of

  12. Recipe Development and Evaluation of the 1983 Revision of the Standard B Ration

    DTIC Science & Technology

    1983-04-01

    Soup and gravy base, instant , beef flavored Soup, dehydrated, beef flavored w/ noodles and vegetables Soup, dehydrated, chicken flavored w/ noodles ...Soup, dehydrated, onion Soup, dehydrated, tomato-vegetable, w/ noodles Soup and gravy base, instant , beef flavored Soup and gravy base, instant ...Strawberry Jam Peanut Butter Coffee (A-2) Cocoa Lunch Chicken Noodle Soup (1-2) w/Cr ackers Luncheon Meat Sandwich (G-38) Mustard Baked

  13. Effect of salt intensity in soup on ad libitum intake and on subsequent food choice.

    PubMed

    Bolhuis, Dieuwerke P; Lakemond, Catriona M M; de Wijk, Rene A; Luning, Pieternel A; de Graaf, Cees

    2012-02-01

    The effect of salt intensity on ad libitum intake of tomato soup was investigated when soup was served as a first course and as a second course. Also the effect of salt intensity in soup on subsequent sweet vs. savory choice of sandwich fillings was investigated. Forty-three healthy subjects consumed ad libitum a low-salt (LS), ideal-salt (IS) and high-salt (HS) tomato soup in both meal settings. The salt concentrations were selected on an individual basis, in a way that IS was most pleasant and LS and HS were similar in pleasantness. The ad libitum intake of IS soup was higher than that of LS and HS soup, and the ad libitum intake of LS soup was higher than that of HS soup. The meal setting, soup as a first or as a second course, did not affect ad libitum intake. Salt intensity in soup did not predict sweet vs. savory choice of fillings in grams or energy, although most sodium from fillings was consumed after intake of HS soup. In conclusion, a higher salt intensity lead to lower ad libitum intake of soup similar in palatability (LS vs. HS). In addition, salt intensity in soup does not predict sweet vs. savory food choice. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. Tiny Ultraviolet Polarimeter for Earth Stratosphere from Space Investigation

    NASA Astrophysics Data System (ADS)

    Nevodovskyi, P. V.; Morozhenko, O. V.; Vidmachenko, A. P.; Ivakhiv, O.; Geraimchuk, M.; Zbrutskyi, O.

    2015-09-01

    One of the reasons for climate change (i.e., stratospheric ozone concentrations) is connected with the variations in optical thickness of aerosols in the upper sphere of the atmosphere (at altitudes over 30 km). Therefore, aerosol and gas components of the atmosphere are crucial in the study of the ultraviolet (UV) radiation passing upon the Earth. Moreover, a scrupulous study of aerosol components of the Earth atmosphere at an altitude of 30 km (i.e., stratospheric aerosol), such as the size of particles, the real part of refractive index, optical thickness and its horizontal structure, concentration of ozone or the upper border of the stratospheric ozone layer is an important task in the research of the Earth climate change. At present, the Main Astronomical Observatory of the National Academy of Sciences (NAS) of Ukraine, the National Technical University of Ukraine "KPI"and the Lviv Polytechnic National University are engaged in the development of methodologies for the study of stratospheric aerosol by means of ultraviolet polarimeter using a microsatellite. So fare, there has been created a sample of a tiny ultraviolet polarimeter (UVP) which is considered to be a basic model for carrying out space experiments regarding the impact of the changes in stratospheric aerosols on both global and local climate.

  15. Soup preloads in a variety of forms reduce meal energy intake.

    PubMed

    Flood, Julie E; Rolls, Barbara J

    2007-11-01

    Consuming soup can enhance satiety and reduce energy intake. Little is known about the influence on energy intake and satiety of varying the form of soup by altering the blending of ingredients. We tested the effects on meal intake of consuming different forms of soup as a preload: broth and vegetables served separately, chunky vegetable soup, chunky-pureed vegetable soup, or pureed vegetable soup. Normal-weight men and women (n = 60) came to the laboratory for lunch once a week for 5 weeks. Each week, one of four compulsory preloads, or no preload, was consumed prior to lunch. A test meal was consumed ad libitum 15 min after the soup was served. Results showed that consuming soup significantly reduced test meal intake and total meal energy intake (preload + test meal) compared to having no soup. When soup was consumed, subjects reduced meal energy intake by 20% (134+/-25 kcal; 561+/-105 kJ). The type of soup had no significant effect on test meal intake or total meal energy intake. Consuming a preload of low-energy-dense soup, in a variety of forms, is one strategy for moderating energy intake in adults.

  16. The sensory interactions of organic acids and various flavors in ramen soup systems.

    PubMed

    Kang, M-W; Chung, S-J; Lee, H-S; Kim, Y; Kim, K-O

    2007-11-01

    This study was conducted to investigate the sensory interactions between various organic acids and flavorants in 3 types of ramen soup ('beef,' seafood, and 'kimchi') when types and levels of organic acids (citric, malic, and lactic) varied. For 'beef' and seafood ramen soup, weak suprathreshold levels of acids (0.0039% to 0.0071%) were applied to the system and medium suprathreshold of acids (0.0128% to 0.0299%) were applied to the kimchi ramen soup. The amount of acid applied to each system was chosen based on the equiweight level. Descriptive analyses were performed separately for each ramen soup system using 8 trained panelists. A total of 11, 13, and 12 flavor descriptors were generated for 'beef,' seafood, and 'kimchi' soup, respectively. Analysis of variance was conducted to evaluate the effect of organic acid on the sensory characteristics of ramen soup. Principal component analysis was conducted to summarize the relationship between the soup samples and attributes. The effect of organic acids on the flavor attributes of ramen soup was dependent on the soup system as well as adding levels of acid. Addition of lactic acid power (at 0.0066%) in 'beef'ramen soup showed enhancement effect on the sour, salty, beefy, 'mushroom' flavor, and fermented soybean paste soup flavor, whereas lactic acid powder (at 0.0071%) showed enhancement effect only on the sour and fermented soybean paste soup flavor in seafood ramen soup due to the strong 'hot' flavor characteristics of the soup. In kimchi ramen soup, flavor attributes congruent to sourness were enhanced by the addition of organic acids to the system.

  17. About study of radiation flux carried out on the stand, which is designed for testing of space ultraviolet polarimeter

    NASA Astrophysics Data System (ADS)

    Nevodovskiy, P. V.; Vidmachenko, A. P.; Geraimchuk, M. D.; Ivahiv, O. V.

    2016-08-01

    In the Main Astronomical Observatory of NAS of Ukraine, National Technical University of Ukraine "KPI" and National University "Lviv Polytechnic" over the many years has accumulated considerable experience of work on the design and development of polarimeters, and created a working model of compact an onboard ultraviolet polarimeter (UFP) [1-6]. For debugging, research and testing as the entire layout of UFP and its individual parts we have created a special stand with complex equipment that allows carrying the following works. The structural construction of the stand allows obtaining characteristics as a whole unit, and its individual parts; obtaining spectral dependences and counting characteristics signal of the light radiation, and of dark signal; carry out the polarization measurements and more. For this stand developed a number of special techniques to study various parameters of all UFP appliance and its individual parts. Thus, for control - characteristics and calibration of elements of photo-detector system of electro-optical equipment, must use the reference emitters. But they are complicated and expensive. Therefore for simplified calibration and configuration of optical devices, it is expedient to use cheap and small in size, but specially selected LEDs. For this, developed for testing of UFP stand, has been modernized. Thus, the selection was carried out, and then carefully studied the sources of radiation, that will be used for calibration of polarimeters. More information on this work expounded in the report. References. 1. P. Nevodovskyi, O. Morozhenko, A. Vidmachenko, O. Ivakhiv, M. Geraimchuk, O. Zbrutskyi. Tiny Ultraviolet Polarimeter for Earth Stratosphere from Space Investigation // Proceedings of 8th IEEE International Conference on Intelligent Data Acquisition and Advanced Computing Systems: Technology and Applications (IDAACS'2015). 24-26 September 2015, Proceedings. Warsaw, Poland. Vol.81, p. 28-32. 2. Nevodovsksiy P. V., Morozhenko A. V. Studies of stratospheric ozone layer from near-earth orbit utilizing ultraviolet polarimeter // Acta Astronautica. 2009, vol. 64, no. 1, p. 54-58. 3. Nevodovskij P. V. Kvantakons and optimization of their parameters for astronomical observations // Kinematika i Fizika Nebesnykh Tel. 2001, vol. 17, no. 3, p. 279-288. 4. A. P. Vid'machenko, P. V. Nevodovsky. A cooled photomultiplier with an InGaAs photocathode developed for the spectropolarimetry observations // Kinematika i Fizika Nebesnykh Tel. 2000, Suppl. 3, p. 283-285. 5. P. Nevodovsky! i, A. Morozhenko, A. Vidmachenko, M. Geraimchuk, A. Zbrutskyi,! Yu. Kur eniov, V. Sergunin, Yu. Hirniak, O. Ivakhiv. Ultraviolet Polarimeter for Studying the Aerosol Component in the Earth Atmosphere // International Symposium on Atmospheric Radiation and Dynamics. Session 1. "Satellite sounding of atmosphere and surface". ISARD - 2013. June 24-27 2013. Peterhof, St Petersburg, Russia. P. 21.

  18. Commissioning of the Dual-Beam Imaging Polarimeter for the University of Hawaii 88 inch Telescope

    NASA Astrophysics Data System (ADS)

    Masiero, Joseph; Hodapp, Klaus; Harrington, Dave; Lin, Haosheng

    2007-10-01

    In this paper we present the design, calibration method, and initial results of the Dual-Beam Imaging Polarimeter (DBIP). This new instrument is designed to measure the optical polarization properties of point sources, in particular, Main Belt asteroids. This instrument interfaces between the Tek 2048×2048 camera and the University of Hawaii's 88 inch telescope and is available for facility use. Using DBIP we are able to measure linear polarization with a 1 σ Poisson signal noise of 0.03% per measurement and a systematic error of order 0.06%+/-0.02%. In addition, we discuss measurements of the polarization of the asteroid 16 Psyche that were taken as part of the instrument commissioning. We confirm Psyche's negative polarization of -1.037%+/-0.006% but find no significant modulation of the signal with rotation above the 0.05% polarization level.

  19. Simultaneous quantification by HPLC of purines in umami soup stock and evaluation of their effects on extracellular and intracellular purine metabolism.

    PubMed

    Fukuuchi, T; Iyama, N; Yamaoka, N; Kaneko, K

    2018-04-13

    Ribonucleotide flavor enhancers such as inosine monophosphate (IMP) and guanosine monophosphate (GMP) provide umami taste, similarly to glutamine. Japanese cuisine frequently uses soup stocks containing these nucleotides to enhance umami. We quantified 18 types of purines (nucleotides, nucleosides, and purine bases) in three soup stocks (chicken, consommé, and dried bonito soup). IMP was the most abundant purine in all umami soup stocks, followed by hypoxanthine, inosine, and GMP. The IMP content of dried bonito soup was the highest of the three soup stocks. We also evaluated the effects of these purines on extracellular and intracellular purine metabolism in HepG2 cells after adding each umami soup stock to the cells. An increase in inosine and hypoxanthine was evident 1 h and 4 h after soup stock addition, and a low amount of xanthine and guanosine was observed in the extracellular medium. The addition of chicken soup stock resulted in increased intracellular and extracellular levels of uric acid and guanosine. Purine metabolism may be affected by ingredients present in soups.

  20. GASP-Galway astronomical Stokes polarimeter

    NASA Astrophysics Data System (ADS)

    Kyne, G.; Sheehan, B.; Collins, P.; Redfern, M.; Shearer, A.

    2010-06-01

    The Galway Astronomical Stokes Polarimeter (GASP) is an ultra-high-speed, full Stokes, astronomical imaging polarimeter based upon a Division of Amplitude Polarimeter. It has been developed to resolve extremely rapid stochastic (~ms) variations in objects such as optical pulsars, magnetars and magnetic cataclysmic variables. The polarimeter has no moving parts or modulated components so the complete Stokes vector can be measured from just one exposure - making it unique to astronomy. The time required for the determination of the full Stokes vector is limited only by detector efficiency and photon fluxes. The polarimeter utilizes a modified Fresnel rhomb that acts as a highly achromatic quarter wave plate and a beamsplitter (referred to as an RBS). We present a description of how the DOAP works, some of the optical design for the polarimeter. Calibration is an important and difficult issue with all polarimeters, but particularly in astronomical polarimeters. We give a description of calibration techniques appropriate to this type of polarimeter.

  1. Effect of umami taste on pleasantness of low-salt soups during repeated testing.

    PubMed

    Roininen, K; Lähteenmäki, L; Tuorila, H

    1996-09-01

    In the present study the effects of the umami substances, monosodium glutamate (0.2%) and 5'-ribonucleotides (0.05%), on the acceptance of low-salt soups in two groups of subjects, one with low-salt (n = 21) and the other with high-salt (n = 23) preferences were assessed. The groups were presented with soups containing 0.3% sodium chloride (low-salt group) and 0.5% sodium chloride (high-salt group). The subjects three times consumed leek-potato or minestrone soup with umami and three times the other soup without umami during six sessions over 5 weeks (sessions 2-7). In addition they tasted these and two other soups (lentil and mushroom soup) during sessions 1 and 8, during which they evaluated the pleasantness, taste intensity, and ideal saltiness of the soups with and without added umami. These ratings were higher when soups contained umami in both the low- and high-salt groups, and they remained higher regardless of which of the soups served for lunch contained umami. The low- and high-salt groups did not differ in pleasantness ratings, although the former rated the taste intensity of their soups higher and ideal saltiness closer to the ideal than did the latter. The pleasantness ratings of soups without umami were significantly lower at the end of the study than at the beginning, whereas those of soups with umami remained unchanged. These data suggest that the pleasantness of reduced-salt foods could be increased by addition of appropriate flavors.

  2. Soup consumption is associated with a reduced risk of overweight and obesity but not metabolic syndrome in US adults: NHANES 2003-2006.

    PubMed

    Zhu, Yong; Hollis, James H

    2013-01-01

    A limited number of studies have found that soup consumption is related to a lower risk of overweight and obesity in Asian and European populations, however, these studies do not provide a consistent picture regarding the association between soup consumption and markers of metabolic syndrome. To date, no study examining the relationship between soup and body weight or metabolic syndrome have been conducted in the US population. The present study used a sample of 4158 adults aged 19-64 who participated in the National Health and Nutrition Examination Survey between 2003 and 2006. The frequency of soup consumption was determined using a food frequency questionnaire. The weighted prevalence of soup consumption was 94%, with a seasonal variation in the frequency of soup consumption being found. Non-consumers of soup were at a higher risk of being overweight or obese (adjusted odds ratio = 1.381, P = 0.013), with a higher adjusted prevalence of reduced HDL cholesterol (adjusted odds ratio = 1.280, P = 0.045), but there was no association between soup consumption and metabolic syndrome (P = 0.520). The frequency of soup consumption was inversely associated with covariate-adjusted body mass index and waist circumference (P<0.05), but not with biomarkers of metabolic syndrome, except for a lower fasting insulin level in frequent soup consumers (P = 0.022). Results from the present study suggest soup consumption is not associated with metabolic syndrome. However, there is an inverse relationship between soup consumption and body weight status in US adults, which support laboratory studies showing a potential benefit of soup consumption for body weight management.

  3. Soup Consumption Is Associated with a Reduced Risk of Overweight and Obesity but Not Metabolic Syndrome in US Adults: NHANES 2003–2006

    PubMed Central

    Zhu, Yong; Hollis, James H.

    2013-01-01

    A limited number of studies have found that soup consumption is related to a lower risk of overweight and obesity in Asian and European populations, however, these studies do not provide a consistent picture regarding the association between soup consumption and markers of metabolic syndrome. To date, no study examining the relationship between soup and body weight or metabolic syndrome have been conducted in the US population. The present study used a sample of 4158 adults aged 19–64 who participated in the National Health and Nutrition Examination Survey between 2003 and 2006. The frequency of soup consumption was determined using a food frequency questionnaire. The weighted prevalence of soup consumption was 94%, with a seasonal variation in the frequency of soup consumption being found. Non-consumers of soup were at a higher risk of being overweight or obese (adjusted odds ratio = 1.381, P = 0.013), with a higher adjusted prevalence of reduced HDL cholesterol (adjusted odds ratio = 1.280, P = 0.045), but there was no association between soup consumption and metabolic syndrome (P = 0.520). The frequency of soup consumption was inversely associated with covariate-adjusted body mass index and waist circumference (P<0.05), but not with biomarkers of metabolic syndrome, except for a lower fasting insulin level in frequent soup consumers (P = 0.022). Results from the present study suggest soup consumption is not associated with metabolic syndrome. However, there is an inverse relationship between soup consumption and body weight status in US adults, which support laboratory studies showing a potential benefit of soup consumption for body weight management. PMID:24098709

  4. Serving large portions of vegetable soup at the start of a meal affected children's energy and vegetable intake.

    PubMed

    Spill, Maureen K; Birch, Leann L; Roe, Liane S; Rolls, Barbara J

    2011-08-01

    This study tested whether varying the portion of low-energy-dense vegetable soup served at the start of a meal affects meal energy and vegetable intakes in children. Subjects were 3- to 5-year-olds (31 boys and 41 girls) in daycare facilities. Using a crossover design, children were served lunch once a week for four weeks. On three occasions, different portions of tomato soup (150, 225, and 300 g) were served at the start of the meal, and on one occasion no soup was served. Children had 10 min to consume the soup before being served the main course. All foods were consumed ad libitum. The primary outcomes were soup intake as well as energy and vegetable intake at the main course. A mixed linear model tested the effect of soup portion size on intake. Serving any portion of soup reduced entrée energy intake compared with serving no soup, but total meal energy intake was only reduced when 150 g of soup was served. Increasing the portion size increased soup and vegetable intake. Serving low-energy-dense, vegetable soup as a first course is an effective strategy to reduce children's intake of a more energy-dense main entrée and increase vegetable consumption at the meal. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Serving large portions of vegetable soup at the start of a meal affected children’s energy and vegetable intake

    PubMed Central

    Spill, Maureen K.; Birch, Leann L.; Roe, Liane S.; Rolls, Barbara J.

    2011-01-01

    This study tested whether varying the portion of low-energy-dense vegetable soup served at the start of a meal affects meal energy and vegetable intakes in children. Subjects were 3- to 5-year-olds (31 boys and 41 girls) in daycare facilities. Using a crossover design, children were served lunch once a week for four weeks. On three occasions, different portions of tomato soup (150, 225, and 300 g) were served at the start of the meal, and on one occasion no soup was served. Children had 10 minutes to consume the soup before being served the main course. All foods were consumed ad libitum. The primary outcomes were soup intake as well as energy and vegetable intake at the main course. A mixed linear model tested the effect of soup portion size on intake. Serving any portion of soup reduced entrée energy intake compared with serving no soup, but total meal energy intake was only reduced when 150 g of soup was served. Increasing the portion size increased soup and vegetable intake. Serving low-energy-dense, vegetable soup as a first course is an effective strategy to reduce children’s intake of a more energy-dense main entrée and increase vegetable consumption at the meal. PMID:21596073

  6. The Cosmology Large Angular Scale Surveyor (CLASS) Telescope Architecture

    NASA Technical Reports Server (NTRS)

    Chuss, David T.; Ali, Aamir; Amiri, Mandana; Appel, John W.; Araujo, Derek; Bennett, Charles L.; Boone, Fletcher; Chan, Manwei; Cho, Hsiao-Mei; Colazo, Felipe; hide

    2014-01-01

    We describe the instrument architecture of the Johns Hopkins University-led CLASS instrument, a groundbased cosmic microwave background (CMB) polarimeter that will measure the large-scale polarization of the CMB in several frequency bands to search for evidence of inflation.

  7. Effect of salt intensity on ad libitum intake of tomato soup similar in palatability and on salt preference after consumption.

    PubMed

    Bolhuis, Dieuwerke P; Lakemond, Catriona M M; de Wijk, Rene A; Luning, Pieternel A; de Graaf, Cees

    2010-11-01

    Sensory properties of food play an important role in satiation. Studies on the effect of taste intensity on satiation show conflicting results. This may be due to the notion that in these studies taste intensity and palatability were confounded. The objective of this study was to investigate the effect of salt intensity of tomato soup on ad libitum intake (satiation), while controlling for palatability on an individual basis. Forty-eight subjects consumed both a low-salt (LS) and high-salt (HS) soup ad libitum from a self-refilling bowl. The results showed no difference between LS and HS soup in ad libitum intake, eating rate, changes in appetite ratings, and changes in hedonic ratings after intake. After intake of HS soup, LS soup was perceived as more bland than before intake of HS soup. After intake of LS soup, HS soup was perceived as more salt intense than before intake of LS soup. In conclusion, this study found no effect of salt intensity on satiation of tomato soups that were similar in palatability. During consumption, subjects adapted quickly to the exposed salt intensity as contrasting salt intensities were rated further from the ideal salt intensity and therefore perceived as less pleasant after consumption.

  8. Columbia University OSO-8 instrument for stellar and solar X-ray spectroscopy and polarimetry

    NASA Technical Reports Server (NTRS)

    Wolff, R. S.

    1976-01-01

    A spectrometer and a polarimeter consisting of large-area panels of mosaic crystals have been constructed and prepared for use in the OSO-8 satellite. The instrumentation is planned for study of stellar and solar X-ray spectra between 1.8-8 keV and stellar X-ray polarization at 2.6 keV. Aspects of the design which enable the instrument to make measurements of the diverse range of stellar and solar phenomena are described. Some of the unique features, such as high sensitivity, high temporal resolution, and spectral range, are discussed. The applicability of the spectrometer and polarimeter to various current problems in X-ray astronomy is considered.

  9. Soups increase satiety through delayed gastric emptying yet increased glycaemic response.

    PubMed

    Clegg, M E; Ranawana, V; Shafat, A; Henry, C J

    2013-01-01

    Previous studies have demonstrated the satiating properties of soups compared with solids; however, the mechanisms controlling soup-induced satiety are unknown. This study aimed to understand the physiological mechanisms causing soup to be more satiating. A total of 12 volunteers were tested on three occasions after a solid meal, chunky soup or smooth soup test meal for gastric emptying (GE) using the sodium [1-¹³C] acetate breath test, satiety using visual analog scales (VAS) and glycaemic response (GR) using finger prick blood samples. There was a significant difference in GE half-time (P=0.022) and GE ascension time (P=0.018), with the longest GE times for the smooth soup and the shortest for the solid meal. The GR area under the curve was significantly different between meals (P=0.040). The smooth soup had the greatest GR (87.0 ± 49.5 mmol/l/min), followed by the chunky soup (65.4 ± 48.0 mmol/l/min), with the solid meal having the lowest GR (61.6 ± 36.8 mmol/l/min). Volunteers were fuller after the smooth soup compared with solid meal (P=0.034). The smooth soup induced greater fullness compared with the solid meal because of a combination of delayed GE leading to feelings of gastric distension and rapid accessibility of nutrients causing a greater glycaemic response.

  10. Variation in saltiness perception of soup with respect to soup serving temperature and consumer dietary habits.

    PubMed

    Kim, Jeong-Weon; Samant, Shilpa S; Seo, Yoojin; Seo, Han-Seok

    2015-01-01

    Little is known about the effect of serving temperature on saltiness perception in food products such as soups that are typically consumed at high temperature. This study focused on determining whether serving temperature modulates saltiness perception in soup-base products. Eight trained panelists and 62 untrained consumers were asked to rate saltiness intensities in salt water, chicken broth, and miso soup, with serving temperatures of 40, 50, 60, 70, and 80 °C. Neither trained nor untrained panelists were able to find significant difference in the saltiness intensity among salt water samples served at these five different temperatures. However, untrained consumers (but not trained panelists) rated chicken broth and miso soup to be significantly less salty when served at 70 and/or 80 °C compared to when served at 40 to 60 °C. There was an interaction between temperature-related perceived saltiness and preference; for example, consumers who preferred soups served at lower temperatures found soups served at higher temperatures to be less salty. Consumers who frequently consumed hot dishes rated soup samples served at 60 °C as saltier than consumers who consumed hot dishes less frequently. This study demonstrates that soup serving temperature and consumer dietary habits are influential factors affecting saltiness perception of soup. Published by Elsevier Ltd.

  11. An analysis of un-dissolved powders of instant powdered soup by using ultrasonographic image

    NASA Astrophysics Data System (ADS)

    Kawaai, Yukinori; Kato, Kunihito; Yamamoto, Kazuhiko; Kasamatsu, Chinatsu

    2008-11-01

    Nowadays, there are many instant powdered soups around us. When we make instant powdered soup, sometimes we cannot dissolve powders perfectly. Food manufacturers want to improve this problem in order to make better products. Therefore, they have to measure the state and volume of un-dissolved powders. Earlier methods for analyzing removed the un-dissolved powders from the container, the state of the un-dissolved power was changed. Our research using ultrasonographic image can measure the state of un-dissolved powders with no change by taking cross sections of the soup. We then make 3D soup model from these cross sections of soup. Therefore we can observe the inside of soup that we do not have ever seen. We construct accurate 3D model. We can visualize the state and volume of un-dissolved powders with analyzing the 3D soup models.

  12. Astronomy in Denver: Probing Interstellar Circular Polarization with Polvis, a Full Stokes Single Shot Polarimeter

    NASA Astrophysics Data System (ADS)

    Wolfe, Tristan; Stencel, Robert E.

    2018-06-01

    Measurements of optical circular polarization (Stokes V) introduced by dust grains in the ISM are important for two main reasons. First of all, the polarization itself contains information about the metallic versus dielectric composition of the dust grains themselves (H. C. van de Hulst 1957, textbook). Additionally, circular polarization can help constrain the interstellar component of the polarization of any source that may have intrinsic polarization, which needs to be calibrated for astrophysical study. Though interstellar circular polarization has been observed (P. G. Martin 1972, MNRAS 159), most broadband measurements of ISM polarization include linear polarization only (Stokes Q and U), due to the relatively low circular polarization signal and the added instrumentation complexity of including V-measurement capability. Prior circular polarization measurements have also received very little follow-up in the past several decades, even as polarimeters have become more accurate due to advances in technology. The University of Denver is pursuing these studies with POLVIS, a prototype polarimeter that utilizes a stress-engineered optic ("SEO", A. K. Spilman and T. G. Brown 2007, Applied Optics IP 46) to produce polarization-dependent PSFs (A. M. Beckley and T. G. Brown 2010, Proc SPIE 7570). These PSFs are analyzed to provide simultaneous Stokes I, Q, U, and V measurements, in a single beam and single image, along the line-of-sight to point source-like objects. Polvis is the first polarimeter to apply these optics and measurement techniques for astronomical observations. We present the first results of this instrument in B, V, and R wavebands, providing a fresh look at full Stokes interstellar polarization. Importantly, this set of efforts will constrain the ISM contribution to the polarization with respect to intrinsic stellar components. The authors are grateful to the estate of William Herschel Womble for the support of astronomy at the University of Denver, and for funding provided by the Mt. Cuba Astronomical Foundation.

  13. Preparing Soups. Learning Activity Pack and Instructor's Guide 5.10b. Commercial Foods and Culinary Arts Competency-Based Series. Section 5: Basic Food Preparation.

    ERIC Educational Resources Information Center

    Florida State Univ., Tallahassee. Center for Studies in Vocational Education.

    This document consists of a learning activity packet (LAP) for the student and an instructor's guide for the teacher. The LAP is intended to acquaint occupational home economics students with preparing and serving soups. Illustrated information sheets and learning activities are provided in these areas: thin soups, thick soups, convenience soups,…

  14. Formulation and nutritional evaluation of a healthy vegetable soup powder supplemented with soy flour, mushroom, and moringa leaf.

    PubMed

    Farzana, Tasnim; Mohajan, Suman; Saha, Trissa; Hossain, Md Nur; Haque, Md Zahurul

    2017-07-01

    The research study was conducted to develop a healthy vegetables soup powder supplemented with soy flour, mushroom, moringa leaf and compare its nutritional facts with locally available soup powders. Proximate analysis and sensory evaluation were done by standard method. In this study, moisture, ash, protein, fat, fiber, carbohydrate, and energy content were ranged from 2.83% to 5.46%, 9.39% to 16.48%, 6.92% to 16.05%, 4.22% to 6.39%, 0.22% to 1.61%, 58.81% to 75.41%, and 337.42 to 386.72 kcal/100 g, respectively. Highest content of vitamin D, minerals, protein, and fiber and lowest content of moisture, fat, and carbohydrate were found in the presently developed soy-mushroom-moringa soup powder compare to locally available soup powders. Vitamin C was also found significantly higher than locally available soup powders S1, S2, and S3. Heavy metals were not found in any of the soup powders. On the sensory and microbiological point of view, the presently developed soup powder was found highly acceptable up to 6 months. So, the developed soy-mushroom-moringa soup powder is nutritionally superior to locally available soup powders and sufficient to meet day-to-day nutritional requirements as a supplement.

  15. A Soup Service for Advanced Digestive Cancer Patients with Severe Anorexia in Palliative Care.

    PubMed

    Kawabata, Hideaki; Kakihara, Naoki; Nishitani, Yoko; Asano, Kota; Nose, Mariko; Takanashi, Asami; Kanda, Eiichiro; Nishimura, Masako; Tokunaga, Eiko; Matsurugi, Ayako; Fujimura, Keiko; Nishikawa, Masanori; Taga, Chiaki; Ikawa, Osamu; Yamaguchi, Makiko; Masuda, Katsuhiko

    2018-03-01

    The palliative care team (PCT), nutrition support team (NST), and department of nutrition in our hospital developed a special soup service for patients with terminal cancer. We evaluated the usefulness of this soup service for improving the mood in patients with advanced digestive cancer with severe anorexia. We retrospectively reviewed the clinical data of 18 patients with advanced cancer originating in digestive organs who received soup service at our institution between 2015 and 2016. Members of the PCT, NST, and a licensed cook visited the bedside of each patient and served them a cup of soup twice a week. Fifteen patients (83%) were able to taste the soup with no adverse events, and 11 (73%) of them enjoyed the taste of the soup. In the five patients who died in our hospital during the service, the time between their last soup intake and death ranged from two to seven days (median three days). Even terminally ill patients suffering from advanced digestive cancer with severe anorexia were able to enjoy the taste of the soup served to them. The establishment of special meal service, such as this soup service, may not only relieve their stress but also support the strength of living and help improve their spiritual quality of life.

  16. Alphabet Soup: School Library Media Education in the United States

    ERIC Educational Resources Information Center

    Underwood, Linda

    2007-01-01

    Universities offering school library media programs seek accreditation from various regional and national organizations. This accreditation makes the programs valid and marketable. School media programs within a college of education seek accreditation from specialized accrediting bodies. The National Council for Accreditation of Teacher Education…

  17. Evaluation of Australian soup manufacturer compliance with national sodium reduction targets.

    PubMed

    Levi, Rebecca; Probst, Yasmine; Crino, Michelle; Dunford, Elizabeth

    2018-04-01

    Packaged foods dominate Australia's food supply and are important contributors to nutrition-related disease. To help address this problem, the Food and Health Dialogue (FHD) was launched in 2009, setting voluntary sodium reduction targets for various categories of packaged foods. The aim of this study was to examine the food industry's progress and compliance with the FHD sodium reduction targets for soup products. Nutritional information was collected from product labels of all soup products available from four major Australian supermarkets annually between 2011 and 2014. Products were assigned to categories in line with those in the FHD. The proportion of soup products meeting sodium reduction targets was examined by (i) soup category; (ii) FHD participant status; and (iii) manufacturer. A 6% reduction in sodium levels in soups overall was found from 2011 to 2014 (P = 0.002). Significant reductions were observed for FHD participants (P < 0.05 for all) but not for non-participants. In 2014, 67% dry soups and 76% of wet soups met national sodium reduction targets. Despite the majority of soup products meeting the sodium reduction targets specified by the FHD, re-evaluation of the targets may be required to further reduce sodium levels in soups. Manufacturers participating in the FHD are likely to be driving sodium reductions in the Australian soup market, further highlighting the need for continued government leadership in this area to ensure all manufacturers are actively involved in the process. © 2017 Dietitians Association of Australia.

  18. Monosodium L-glutamate in soup reduces subsequent energy intake from high-fat savoury food in overweight and obese women.

    PubMed

    Miyaki, Takashi; Imada, Toshifumi; Hao, Susan Shuzhen; Kimura, Eiichiro

    2016-01-14

    The umami seasoning, monosodium L-glutamate (MSG), has been shown to increase satiety in normal body weight adults, although the results have not been consistent. The satiety effect of MSG in overweight and obese adults has not been examined yet. The objective of the present study was to investigate the effect of MSG in a vegetable soup on subsequent energy intakes as well as food selection in overweight and obese adult women without eating disorders. A total of sixty-eight overweight and obese women (BMI range: 25·0-39·9 kg/m²), otherwise healthy, were recruited to our study. A fixed portion (200 ml) of control vegetable soup or the same soup with added MSG (0·5 g/100 ml) was provided 10 min before an ad libitum lunch and an ad libitum snack in the mid-afternoon. The control soup had equivalent amount of Na to the soup with added MSG. Energy intakes at the ad libitum lunch and ad libitum snack time after the soup preload were assessed using a randomised, double-blind, two-way cross-over design. The soup with MSG in comparison with the control soup resulted in significantly lower consumption of energy at lunch. The addition of MSG in the soup also reduced energy intake from high-fat savoury foods. The soup with MSG showed lower but no significant difference in energy intake at mid-afternoon. The addition of umami seasoning MSG in a vegetable soup may decrease subsequent energy intake in overweight and obese women who do not have eating disorders.

  19. [Shenghua soup: a study of the relationships among related knowledge, expected effectiveness, and consumption behavior in postpartum women].

    PubMed

    Liu, Shu-Hsun; Wang, Hsiao-Ling; Kuo, Shih-Hsien; Chou, Fan-Hao

    2013-02-01

    Women in Taiwan are concerned about postpartum personal healthcare, and over 90% consume Shenghua soup as part of their postpartum recovery regimen. However, knowledge regarding Shenghua soup is inadequate among this population. Therefore, the correlation between Shenghua soup knowledge and consumption behavior deserves further clarification. The study explores the relationships among Shenghua soup knowledge, expected effectiveness, and consumption behavior in postpartum women. A descriptive and correlational research design recruited a convenience sample of 515 < 30-days postpartum women from local specialty hospitals and postpartum centers. (1) Participant education level had a significant impact on Shenghua soup consumption behavior. Those with bachelor and master school degrees earned a higher average score than those educated to the senior high school level; (2) Knowledge correlated significantly and positively with expected effectiveness (r = .14, p < .001) and consumption behavior (r = .12, p < .001). Consumption behavior correlated positively with expected effectiveness (r = .11, p < .05); (3) Marital status, knowledge and expected effectiveness were identified as significant predictors of Shenghua soup consumption behavior; (4) Principal sources of participant information on Shenghua soup were family members (30.84%), media (26.65%), and medical staff (16.44%); (5) Knowledge scores for over half of participants were in the "wrong" to "no idea" range; and (6) 66.6% of participants took Chinese and Western medicines to help uterine contraction, while 76% had consumed Shenghua soup. Findings indicate that postpartum women in Taiwan have insufficient and incorrect knowledge regarding Shenghua soup; hold positive expectations regarding Shenghua soup effectiveness; and have a high Shenghua soup consumption rate. This study may serve as a postpartum care reference for healthcare professionals to improve the postpartum health of women.

  20. Intrinsic coincident full-Stokes polarimeter using stacked organic photovoltaics and architectural comparison of polarimeter techniques

    NASA Astrophysics Data System (ADS)

    Yang, Ruonan; Sen, Pratik; O'Connor, B. T.; Kudenov, M. W.

    2017-08-01

    An intrinsic coincident full-Stokes polarimeter is demonstrated by using stain-aligned polymer-based organic photovoltaics (OPVs) which can preferentially absorb certain polarized states of incident light. The photovoltaic-based polarimeter is capable of measuring four stokes parameters by cascading four semitransparent OPVs in series along the same optical axis. Two wave plates were incorporated into the system to modulate the S3 stokes parameter so as to reduce the condition number of the measurement matrix. The model for the full-Stokes polarimeter was established and validated, demonstrating an average RMS error of 0.84%. The optimization, based on minimizing the condition number of the 4-cell OPV design, showed that a condition number of 2.4 is possible. Performance of this in-line polarimeter concept was compared to other polarimeter architectures, including Division of Time (DoT), Division of Amplitude (DoAm), Division of Focal Plane (DoFP), and Division of Aperture (DoA) from signal-to-noise ratio (SNR) perspective. This in-line polarimeter concept has the potential to enable both high temporal (as compared with a DoT polarimeter) and high spatial resolution (as compared with DoFP and DoA polarimeters). We conclude that the intrinsic design has the same √2 SNR advantage as the DoAm polarimeter, but with greater compactness.

  1. Enhancing consumer liking of low salt tomato soup over repeated exposure by herb and spice seasonings.

    PubMed

    Ghawi, Sameer Khalil; Rowland, Ian; Methven, Lisa

    2014-10-01

    There is strong evidence for the link between high dietary sodium and increased risk of cardiovascular disease which drives the need to reduce salt content in foods. In this study, herb and spice blends were used to enhance consumer acceptability of a low salt tomato soup (0.26% w/w). Subjects (n = 148) scored their liking of tomato soup samples over 5 consecutive days. The first and last days were pre-and post-exposure visits where all participants rated three tomato soup samples; standard, low salt and low salt with added herbs and spices. The middle 3 days were the repeated exposure phase where participants were divided into three balanced groups; consuming the standard soup, the low salt soup, or the low salt soup with added herbs and spices. Reducing salt in the tomato soup led to a significant decline in consumer acceptability, and incorporating herbs and spices did not lead to an immediate enhancement in liking. However, inclusion of herbs and spices enhanced the perception of the salty taste of the low salt soup to the same level as the standard. Repeated exposure to the herbs and spice-modified soup led to a significant increase in the overall liking and liking of flavour, texture and aftertaste of the soup, whereas no changes in liking were observed for the standard and low salt tomato soups over repeated exposure. Moreover, a positive trend in increasing the post-exposure liking of the herbs and spices soup was observed. The findings suggest that the use of herbs and spices is a useful approach to reduce salt content in foods; however, herbs and spices should be chosen carefully to complement the food as large contrasts in flavour can polarise consumer liking. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  2. The Effects of the Habitual Consumption of Miso Soup on the Blood Pressure and Heart Rate of Japanese Adults: A Cross-sectional Study of a Health Examination.

    PubMed

    Ito, Koji; Miyata, Kenji; Mohri, Masahiro; Origuchi, Hideki; Yamamoto, Hideo

    Objective It is recommended that middle-aged and elderly individuals reduce their salt intake because of the high prevalence of hypertension. The consumption of miso soup is associated with salt intake, and the reduced consumption of miso soup has been recommended. Recent studies have demonstrated that the consumption of miso soup can attenuate an autonomic imbalance in animal models. However, it is unclear whether these results are applicable to humans. This study examined the cross-sectional association between the frequency of miso soup consumption and the blood pressure and heart rate of human subjects. Methods A total of 527 subjects of 50 to 81 years of age who participated in our hospital health examination were enrolled in the present study and divided into four groups based on the frequency of their miso soup consumption ([bowl(s) of miso soup/week] Group 1, <1; Group2, <4; Group3, <7; Group4, ≥7). The blood pressure levels and heart rates of the subjects in each group were compared. Furthermore, a multivariable analysis was performed to determine whether miso soup consumption was an independent factor affecting the incidence of hypertension or the heart rate. Results The frequency of miso soup consumption was not associated with blood pressure. The heart rate was, however, lower in the participants who reported a high frequency of miso soup consumption. A multivariable analysis revealed that the participants who reported a high frequency of miso soup consumption were more likely to have a lower heart rate, but that the consumption of miso soup was not associated with the incidence of hypertension. Conclusion These results indicate that miso soup consumption might decrease the heart rate, but not have a significant effect on the blood pressure of in middle-aged and elderly Japanese individuals.

  3. The Effects of the Habitual Consumption of Miso Soup on the Blood Pressure and Heart Rate of Japanese Adults: A Cross-sectional Study of a Health Examination

    PubMed Central

    Ito, Koji; Miyata, Kenji; Mohri, Masahiro; Origuchi, Hideki; Yamamoto, Hideo

    2017-01-01

    Objective It is recommended that middle-aged and elderly individuals reduce their salt intake because of the high prevalence of hypertension. The consumption of miso soup is associated with salt intake, and the reduced consumption of miso soup has been recommended. Recent studies have demonstrated that the consumption of miso soup can attenuate an autonomic imbalance in animal models. However, it is unclear whether these results are applicable to humans. This study examined the cross-sectional association between the frequency of miso soup consumption and the blood pressure and heart rate of human subjects. Methods A total of 527 subjects of 50 to 81 years of age who participated in our hospital health examination were enrolled in the present study and divided into four groups based on the frequency of their miso soup consumption ([bowl(s) of miso soup/week] Group 1, <1; Group2, <4; Group3, <7; Group4, ≥7). The blood pressure levels and heart rates of the subjects in each group were compared. Furthermore, a multivariable analysis was performed to determine whether miso soup consumption was an independent factor affecting the incidence of hypertension or the heart rate. Results The frequency of miso soup consumption was not associated with blood pressure. The heart rate was, however, lower in the participants who reported a high frequency of miso soup consumption. A multivariable analysis revealed that the participants who reported a high frequency of miso soup consumption were more likely to have a lower heart rate, but that the consumption of miso soup was not associated with the incidence of hypertension. Conclusion These results indicate that miso soup consumption might decrease the heart rate, but not have a significant effect on the blood pressure of in middle-aged and elderly Japanese individuals. PMID:28049996

  4. The White Mountain Polarimeter: A telescope to measure polarization of the cosmic microwave background

    NASA Astrophysics Data System (ADS)

    Levy, Alan Robert

    2006-07-01

    The past two decades have been an exciting time in the field of cosmology and, in particular, studies of the Cosmic Microwave Background (CMB). One of the hot topics in cosmology research today is measuring and mapping CMB polarization. The White Mountain Polarimeter (WMPol) is a dedicated, ground-based microwave telescope and receiver system to measure CMB polarization which was installed in the Barcroft Observatory of the University of California White Mountain Research Station in September 2003. Presented here is a brief review of our current understanding of big bang cosmology and a description of the WMPol instrument, the observing conditions at the 3880-meter altitude Barcroft site, the data acquired during the 2004 observing campaign, and the data analysis.

  5. [Fluorescence spectra analysis of the scrophularia soup].

    PubMed

    Yan, Li-hua; Song, Feng; Han, Juan; Su, Jing; Qu, Fei-fei; Song, Yi-zhan; Hu, Bo-lin; Tian, Jian-guo

    2008-08-01

    The cold-water and boiled-water soaked scrophularia soups have been prepared. The emission and excitation spectra of each scrophularia soup under different conditions have been measured at room temperature. The pH values of the different scrophularia soups have been also detected. There are obvious differences between the cold-water soaked scrophularia soup and the boiled-water soaked scrophularia. For both soups the emission wavelength increases with the wavelength of the excitation, but the peaks of the emission spectra for cold-water and boiled-water soaked scrophularia soup are different, which are 441 and 532 nm, respectively. Excitation spectrum has double peaks in the cold-water soaked scrophularia soup while only one peak with longer wavelength in the boiled-water soaked one. The pH value changes from 5.5 to 4.1. According to the organic admixture fluorescence mechanism we analyzed the reasons of the experimental results. Through heating, the interaction in different fluorescence molecular and the energy transfer process in the same fluorescence molecular become more active, and the conjugate structures and the generation of hydrogen bonds, increase. The fluorescence measurement is of value for the scrophularia pharmacology analysis and provides an analytical method for the quality identification of scrophularia soup.

  6. Inhibitory effects of mouse bone marrow mesenchymal stem cell soup on staurospurine-induced cell death in MCF-7 and AGS.

    PubMed

    Zhaleh, M; Azadbakht, M; Bidmeshki Pour, A

    2017-01-01

    Staurospurine induces apoptosis in cell line. Bone Marrow Mesenchymal stem cells Soup is a promising tool for cell proliferation via a variety of secreted factors. In this study, we examined the effects of BMSCs Soup on Staurospurine induced-cell death in MCF-7 and AGS cells. There were three Groups: Group I: no incubation with BM Soup; Group II: incubated with 24 h BM Soup; Group III: incubation with 48 h BM Soup. There were two treatments in each group. The treatments were 1μM Staurospurine (Treatment 1) and 0.0 μM Staurospurine (Treatment 2). The cells were cultured in culture medium containing 0.2 % BSA. We obtained the cell viability, cell death and NO concentration. Our results showed that BM soup administration for 48 hours protectsed against 1μM staurosporine concentration induced cell death and reduced cell toxicity in MCF-7 and AGS cells. Cell viability and cell toxicity assay showed that BM soup in time dependent manner increased cell viability (p < 0.05) and cell death assay showed that cell death in time dependent manner was decreased(p < 0.05). Our data showed that BM soup with increasing NO concentration reduced staurospurine induced cell death and cell cytotoxicity (p < 0.05). It's concluded that BMSCs soup suppressed staurospurine-induced cytotoxicity activity process in MCF-7 and AGS cells (Fig. 9, Ref. 79).

  7. An Inquiry Activity for Genetics Using Chromosome Mapping.

    ERIC Educational Resources Information Center

    Leonard, William H.; Snodgrass, George

    1982-01-01

    Concepts to be developed, objectives, and student instructions are provided for an activity useful as an introduction to or review of Mendelian genetics and sex determination. Universal codes (read by optical scanners at supermarket checkout stands) from soup can labels are used as chromosome maps during the activity. (JN)

  8. Identification of the active components in Bone Marrow Soup: a mitigator against irradiation-injury to salivary glands.

    PubMed

    Fang, Dongdong; Hu, Shen; Liu, Younan; Quan, Vu-Hung; Seuntjens, Jan; Tran, Simon D

    2015-11-03

    In separate studies, an extract of soluble intracellular contents from whole bone marrow cells, named "Bone Marrow (BM) Soup", was reported to either improve cardiac or salivary functions post-myocardial infarction or irradiation (IR), respectively. However, the active components in BM Soup are unknown. To demonstrate that proteins were the active ingredients, we devised a method using proteinase K followed by heating to deactivate proteins and for safe injections into mice. BM Soup and "deactivated BM Soup" were injected into mice that had their salivary glands injured with 15Gy IR. Control mice received either injections of saline or were not IR. Results at week 8 post-IR showed the 'deactivated BM Soup' was no better than injections of saline, while injections of native BM Soup restored saliva flow, protected salivary cells and blood vessels from IR-damage. Protein arrays detected several angiogenesis-related factors (CD26, FGF, HGF, MMP-8, MMP-9, OPN, PF4, SDF-1) and cytokines (IL-1ra, IL-16) in BM Soup. In conclusion, the native proteins (but not the nucleic acids, lipids or carbohydrates) were the therapeutic ingredients in BM Soup for functional salivary restoration following IR. This molecular therapy approach has clinical potential because it is theoretically less tumorigenic and immunogenic than cell therapies.

  9. Nutrient changes and antinutrient contents of beniseed and beniseed soup during cooking using a Nigerian traditional method.

    PubMed

    Agiang, M A; Umoh, I B; Essien, A I; Eteng, M U

    2010-10-15

    Evaluations of the effect of prolong cooking on the nutrient and antinutrient composition ofbeniseed and beniseed soup were carried out in this study. Proximate, mineral, vitamin A and C and antinutrient compositions of raw beniseed (BS-R), beniseed boiled (BSB) for 15, 30, 45 and 60 min and beniseed soup (BSS) cooked for the same intervals of time were assessed. Results of the proximate composition analyses showed that raw and boiled beniseed had lower moisture content (5.39-5.51%) than beniseed soups (10.06-15.20%). Nitrogen-free extract (total carbohydrates), fats and phosphorus contents were improved in both the boiled beniseed and beniseed soup while calcium and potassium were increased in the boiled seeds and soup samples respectively. Moisture (in the raw and boiled beniseed), ash, magnesium, zinc, iron contents in both the seed and soup were unchanged in all the samples. Vitamins A and C levels of both boiled beniseed and beniseed soup samples were reduced with increase in cooking time. Beniseed soup had higher protein contents than both the raw and boiled beniseed which decreased with increase in cooking time. Beniseed samples provided good sources of energy (572.97-666.05 kcal/100 g). Except for phytate, the levels of antinutrients tested were lower in the raw and boiled beniseed than in the soup samples which decreased with increase in cooking time. The results are discussed with reference to the effect of prolonged cooking on the nutrient requirements of consumers.

  10. A Simple Polarimeter and Experiments Utilizing an Overhead Projector.

    ERIC Educational Resources Information Center

    Dorn, H. C.; And Others

    1984-01-01

    Although polarimeters that illustrate rotation of plane-polarized light by chiral solutions have been previously described, the polarimeter described in this paper has certain advantages when used in conjunction with an overhead projector. Instructions for constructing this polarimeter and its use in demonstrating the optical activity of sugars…

  11. Stone Soup: The Teacher Leader's Contribution

    ERIC Educational Resources Information Center

    Bambrick-Santoyo, Paul

    2013-01-01

    In the tale of "Stone Soup," a stranger vows to make soup for everyone in a village using only a stone--and convinces everyone in town to throw an ingredient into the stewpot. Schools that need to improve teacher practice quickly can also make stone soup, the author says, by harnessing the power of well-prepared teacher leaders to…

  12. Systematic and Performance Tests of the Hard X-ray Polarimeter X-Calibur

    NASA Astrophysics Data System (ADS)

    Endsley, Ryan; Beilicke, Matthias; Kislat, Fabian; Krawczynski, Henric; X-Calibur/InFOCuS

    2015-01-01

    X-ray polarimetry has great potential to reveal new astrophysical information about the emission processes of high energy sources such as black hole environments, X-ray binary systems, and active galactic nuclei. Here we present the results and conclusions of systematic and performance measurements of the hard X-ray polarimeter, X-Calibur. Designed to be flown on a balloon-borne X-ray telescope, X-Calibur will achieve unprecedented sensitivity and makes use of the fact that polarized X-rays preferentially Compton-scatter perpendicular to their E-field vector. Extensive laboratory measurements taken at Washington University and the Cornell High-Energy Synchrotron Source (CHESS) indicate that X-Calibur combines a detection efficiency on the order of unity with a high modulation factor of µ ≈ 0.5 averaged over the whole detector assembly, and with values up to µ ≈ 0.7 for select subsections of the polarimeter. Additionally, we are able to suppress background flux by more than two orders of magnitude by utilizing an active shield and scintillator coincidence. Comparing laboratory data with Monte Carlo simulations of both polarized and unpolarized hard X-ray beams illustrate that we have an exceptional understanding of the detector response.

  13. Polarimetric survey of main-belt asteroids. V. The unusual polarimetric behavior of V-type asteroids

    NASA Astrophysics Data System (ADS)

    Gil-Hutton, R.; López-Sisterna, C.; Calandra, M. F.

    2017-03-01

    Aims: We present the results of a polarimetric survey of main-belt asteroids at Complejo Astronómico El Leoncito (CASLEO), San Juan, Argentina. The aims of this survey are to increase the database of asteroid polarimetry, to estimate diversity in polarimetric properties of asteroids that belong to different taxonomic classes, and to search for objects that exhibit anomalous polarimetric properties. Methods: The data were obtained using the CASPROF and CASPOL polarimeters at the 2.15 m telescope. The CASPROF polarimeter is a two-hole aperture polarimeter with rapid modulation and CASPOL is a polarimeter based on a CCD detector, which allows us to observe fainter objects with better signal-to-noise ratio. Results: The survey began in 1995 and data on a large sample of asteroids were obtained until 2012. A second period began in 2013 using a polarimeter with a more sensitive detector in order to study small asteroids, families, and special taxonomic groups. We obtained 55 polarimetric measurements for 28 V-type main belt asteroids, all of them polarimetrically observed for the first time. The data obtained in this survey let us find polarimetric parameters for (1459) Magnya and for a group of 11 small V-type objects with similar polarimetric behavior. These polarization curves are unusual since they show a shallow minimum and a small inversion angle in comparison with (4) Vesta, although they have a steeper slope at α0. This polarimetric behavior could be explained by differences in the regoliths of these asteroids. The observations of (2579) Spartacus, and perhaps also (3944) Halliday, indicate a inversion angle larger than 24-25°. Based on observations carried out at the Complejo Astronómico El Leoncito, operated under agreement between the Consejo Nacional de Investigaciones Científicas y Técnicas de la República Argentina and the National Universities of La Plata, Córdoba, and San Juan.

  14. Radiometric and Polarimetric Accuracy Assessment and Calibration of the Hyper-Angular Rainbow Polarimeter (HARP) Instrument

    NASA Astrophysics Data System (ADS)

    McBride, B.; Martins, J. V.; Fernandez Borda, R. A.; Barbosa, H. M.

    2017-12-01

    The Laboratory for Aerosols, Clouds, and Optics (LACO) at the University of Maryland, Baltimore County (UMBC) present a novel, wide FOV, hyper-angular imaging polarimeter for the microphysical sampling of clouds and aerosols from aircraft and space. The instrument, the Hyper-Angular Rainbow Polarimeter (HARP), is a precursor to the multi-angle imaging polarimeter solicited by the upcoming NASA Aerosols, Clouds, and Ecosystems (ACE) mission. HARP currently operates in two forms: a spaceborne CubeSat slated for a January 2018 launch to the ISS orbit, and an identical aircraft platform that participated in the Lake Michigan Ozone Study (LMOS) and Aerosol Characterization from Polarimeter and Lidar (ACEPOL) NASA campaigns in 2017. To ensure and validate the instrument's ability to produce high quality Level 2 cloud and aerosol microphysical products, a comprehensive calibration scheme that accounts for flatfielding, radiometry, and all optical interference processes that contribute to the retrieval of Stokes parameters I, Q, and U, is applied across the entirety of HARP's 114° FOV. We present an innovative calibration algorithm that convolves incident polarization from a linear polarization state generator with intensity information observed at three distinct linear polarizations. The retrieved results are pixel-level, modified Mueller matrices that characterize the entire HARP optical assembly, without the need to characterize every individual element or perform ellipsometric studies. Here we show results from several pre- and post- LMOS campaign radiometric calibrations at NASA GSFC and polarimetric calibration using a "polarization dome" that allows for full-FOV characterization of Stokes parameters I, Q, and U. The polarization calibration is verified by passing unpolarized light through partially-polarized, tilted glass plates with well-characterized degree of linear polarization (DoLP). We apply this calibration to a stratocumulous cloud deck case observed during the LMOS campaign on June 19 2017, and assess the polarized cloudbow for cloud droplet effective radius and variance information at 0.67µm.

  15. Ground-based full-sky imaging polarimeter based on liquid crystal variable retarders.

    PubMed

    Zhang, Ying; Zhao, Huijie; Song, Ping; Shi, Shaoguang; Xu, Wujian; Liang, Xiao

    2014-04-07

    A ground-based full-sky imaging polarimeter based on liquid crystal variable retarders (LCVRs) is proposed in this paper. Our proposed method can be used to realize the rapid detection of the skylight polarization information with hemisphere field-of-view for the visual band. The characteristics of the incidence angle of light on the LCVR are investigated, based on the electrically controlled birefringence. Then, the imaging polarimeter with hemisphere field-of-view is designed. Furthermore, the polarization calibration method with the field-of-view multiplexing and piecewise linear fitting is proposed, based on the rotation symmetry of the polarimeter. The polarization calibration of the polarimeter is implemented with the hemisphere field-of-view. This imaging polarimeter is investigated by the experiment of detecting the skylight image. The consistency between the obtained experimental distribution of polarization angle with that due to Rayleigh scattering model is 90%, which confirms the effectivity of our proposed imaging polarimeter.

  16. Time Projection Chamber Polarimeters for X-ray Astrophysics

    NASA Astrophysics Data System (ADS)

    Hill, Joanne; Black, Kevin; Jahoda, Keith

    2015-04-01

    Time Projection Chamber (TPC) based X-ray polarimeters achieve the sensitivity required for practical and scientifically significant astronomical observations, both galactic and extragalactic, with a combination of high analyzing power and good quantum efficiency. TPC polarimeters at the focus of an X-ray telescope have low background and large collecting areas providing the ability to measure the polarization properties of faint persistent sources. TPCs based on drifting negative ions rather than electrons permit large detector collecting areas with minimal readout electronics enabling wide field of view polarimeters for observing unpredictable, bright transient sources such as gamma-ray bursts. We described here the design and expected performance of two different TPC polarimeters proposed for small explorer missions: The PRAXyS (Polarimetry of Relativistic X-ray Sources) X-ray Polarimeter Instrument, optimized for observations of faint persistent sources and the POET (Polarimetry of Energetic Transients) Low Energy Polarimeter, designed to detect and measure bright transients. also NASA/GSFC.

  17. Maximum bandwidth snapshot channeled imaging polarimeter with polarization gratings

    NASA Astrophysics Data System (ADS)

    LaCasse, Charles F.; Redman, Brian J.; Kudenov, Michael W.; Craven, Julia M.

    2016-05-01

    Compact snapshot imaging polarimeters have been demonstrated in literature to provide Stokes parameter estimations for spatially varying scenes using polarization gratings. However, the demonstrated system does not employ aggressive modulation frequencies to take full advantage of the bandwidth available to the focal plane array. A snapshot imaging Stokes polarimeter is described and demonstrated through results. The simulation studies the challenges of using a maximum bandwidth configuration for a snapshot polarization grating based polarimeter, such as the fringe contrast attenuation that results from higher modulation frequencies. Similar simulation results are generated and compared for a microgrid polarimeter. Microgrid polarimeters are instruments where pixelated polarizers are superimposed onto a focal plan array, and this is another type of spatially modulated polarimeter, and the most common design uses a 2x2 super pixel of polarizers which maximally uses the available bandwidth of the focal plane array.

  18. Volumetric abnormalities of the brain in a rat model of recurrent headache.

    PubMed

    Jia, Zhihua; Tang, Wenjing; Zhao, Dengfa; Hu, Guanqun; Li, Ruisheng; Yu, Shengyuan

    2018-01-01

    Voxel-based morphometry is used to detect structural brain changes in patients with migraine. However, the relevance of migraine and structural changes is not clear. This study investigated structural brain abnormalities based on voxel-based morphometry using a rat model of recurrent headache. The rat model was established by infusing an inflammatory soup through supradural catheters in conscious male rats. Rats were subgrouped according to the frequency and duration of the inflammatory soup infusion. Tactile sensory testing was conducted prior to infusion of the inflammatory soup or saline. The periorbital tactile thresholds in the high-frequency inflammatory soup stimulation group declined persistently from day 5. Increased white matter volume was observed in the rats three weeks after inflammatory soup stimulation, brainstem in the in the low-frequency inflammatory soup-infusion group and cortex in the high-frequency inflammatory soup-infusion group. After six weeks' stimulation, rats showed gray matter volume changes. The brain structural abnormalities recovered after the stimulation was stopped in the low-frequency inflammatory soup-infused rats and persisted even after the high-frequency inflammatory soup stimulus stopped. The changes of voxel-based morphometry in migraineurs may be the result of recurrent headache. Cognition, memory, and learning may play an important role in the chronification of migraines. Reducing migraine attacks has the promise of preventing chronicity of migraine.

  19. Color of hot soup modulates postprandial satiety, thermal sensation, and body temperature in young women.

    PubMed

    Suzuki, Maki; Kimura, Rie; Kido, Yasue; Inoue, Tomoko; Moritani, Toshio; Nagai, Narumi

    2017-07-01

    The color of food is known to modulate not only consumers' motivation to eat, but also thermal perception. Here we investigated whether the colors of hot soup can influence thermal sensations and body temperature, in addition to the food acceptability and appetite. Twelve young female participants consumed commercial white potage soup, modified to yellow or blue by adding food dyes, at 9 a.m. on 3 separated days. During the test, visual impression (willingness to eat, palatability, comfort, warmth, and anxiety) and thermal sensations were self-reported using visual analog scales. Core (intra-aural) and peripheral (toe) temperatures were continuously recorded 10 min before and 60 min after ingestion. Blue soup significantly decreased willingness to eat, palatability, comfort, and warmth ratings, and significantly increased anxiety feelings compared to the white and yellow soups. After ingestion, the blue soup showed significantly smaller satiety ratings and the tendency of lower thermal sensation scores of the whole body compared to the white and yellow soups. Moreover, a significantly greater increase in toe temperature was found with the yellow soup than the white or blue soup. In conclusion, this study provides new evidence that the colors of hot food may modulate postprandial satiety, thermal sensations and peripheral temperature. Such effects of color may be useful for dietary strategies for individuals who need to control their appetite. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Food Allergies and Australian Combat Ration Packs

    DTIC Science & Technology

    2010-05-01

    Beef Noodles , Beef Soup, Beef Teriyaki, Candy Chocolate (M&M’s), Chewing Gum, Chicken Noodles , Chicken Soup, Chocolate Beverage Powder, Chocolate...Minced with Tortellini, Beef Noodles , Beef Soup, Beef Teriyaki, Blackcurrant Fruit Grains, Candy Chocolate (M&M’s), Chewing Gum, Chicken Curry...Chicken Italiano, Chicken Noodles , Chicken Soup, Chocolate Ration, Crispbread Biscuit, Forest Fruits Muesli Bar, Hard Candy, Krispie Biscuit, Lamb with

  1. Frequency of soup intake and amount of dietary fiber intake are inversely associated with plasma leptin concentrations in Japanese adults.

    PubMed

    Kuroda, Motonaka; Ohta, Masanori; Okufuji, Tatsuya; Takigami, Chieko; Eguchi, Masafumi; Hayabuchi, Hitomi; Ikeda, Masaharu

    2010-06-01

    Previous studies have shown that the intake of soup negatively correlates with the body mass index (BMI), suggesting that soup intake reduces the risk of obesity. In this study, to clarify the association of the intake of soup and various nutrients with plasma leptin concentration, a cross-sectional study on 504 Japanese adults aged 20-76 years (103 men and 401 women) was performed. The intake of soup and various nutrients was investigated by food frequency questionnaires. Plasma leptin concentration was measured in fasting blood by radioimmunoassay. The correlation was analyzed by multiple regression analysis. The average frequency of soup intake was 7.6 times/week. The average plasma leptin concentration was 7.76 ng/ml. After adjusting the confounding factors, the frequency of soup intake has a significant inverse association with plasma leptin concentration. Among the macronutrients, only dietary fiber intake negatively correlated with plasma leptin concentration after the adjustment for potential confounding factors. These results suggest that the intakes of soup and dietary fiber were negatively correlated with plasma leptin concentration in Japanese adults. Copyright 2010 Elsevier Ltd. All rights reserved.

  2. [The anti-tumour effect of Wuxing soup and its mechanism in inducing apoptosis of tumour cells mediated by calcium].

    PubMed

    Mo, Fei; Hu, Jing-Ying; Gan, Yu; Zhao, Yang-Xing; Zhao, Xin-Tai

    2008-09-01

    To confirm the anti-cancer effect and mechanism of Wuxing soup. Inhibition of cellular growth under Wuxing soup treatment was observed by MTT; Apoptosis was detected by gel electrophoresis, transmission electron microscopy and FACS; The concentration of calcium was measured by fluorescence probe. After SGC-7901 cell being treated by Wuxing soup, it showed that: 1) Wuxing soup could specifically inhibit cancer cells proliferation in a time and dose dependent manner; 2) Typical apoptotic morphological changes and DNA ladder of SGC-7901 cells were observed; 3) calcium inhibitor Bapta AM could reduce the apoptotic rate and protect SGC-7901 cells in a dose dependent manner. Wuxing soup has an effective inhibition on cancer cells, and can induce SGC-7901 cells to apoptosis by calcium.

  3. The Galway astronomical Stokes polarimeter: optical development

    NASA Astrophysics Data System (ADS)

    Collins, P.; Redfern, M.; Shearer, A.; Sheehan, B.

    2010-06-01

    The acquisition time of astronomical polarimeters has in the past been restricted to by the use of polarimeters utilizing modulated or rotating components [1]. If the polarisation state being measured is changing in the order of nanoseconds, how does one measure this? The Galway Astronomical Stokes Polarimeter (GASP) is an instantaneous full Stokes Division Of Amplitude Polarimeter (DOAP) that has been developed for astronomical imaging polarimetry. It also uses just one camera thus restricting the acquisition time to photon statistics. Following the work of Compain and Drévillon [2], the main component - the Retarding Beam-Splitter, was redesigned and enhanced for imaging use. We present how the polarization and imaging optics were developed to create a broadband imaging instantaneous polarimeter. unknown author type, collab

  4. Consumer acceptance of model soup system with varying levels of herbs and salt.

    PubMed

    Wang, Chao; Lee, Youngsoo; Lee, Soo-Yeun

    2014-10-01

    Although herbs have been reported as one of the most common saltiness enhancers, few studies have focused on the effect of herbs on reducing added sodium as well as the impact of herbs on consumers' overall liking of foods. Therefore, the objectives of this study were to determine the effect of varying levels of herbs on reducing added sodium and consumers' overall liking of soups and identify the impact of salt levels on consumers' overall liking of soups. Overall liking of freshly prepared and retorted canned soups with varying levels of herbs was evaluated before and after adding salt by consumers ad libitum until the saltiness of the soup was just about right for them. The results of the study demonstrated that when the perceived herb flavor increased, the amount of salt consumers added to fresh soups decreased (P ≤ 0.006); however, consumers' overall liking decreased (P ≤ 0.013) as well for the highest level of herb tested in the study. Although overall liking of all canned soups was not significantly decreased by herbs, the amount of salt consumers added was also not significantly decreased when herbs were used. Overall liking of all soups significantly increased after more salt was added (P ≤ 0.001), which indicates that salt level was a dominant factor in affecting consumers' overall liking of soups with varying levels of herbs. These findings imply the role of herbs in decreasing salt intake, and the adequate amount of herbs to be added in soup systems. It is challenging for the food industry to reduce sodium in foods without fully understanding the impact of sodium reduction on sensory properties of foods. Herbs are recommended to use in reducing sodium; however, little has been reported regarding the effect of herbs on sodium reduction and how herbs influence consumers’ acceptance of foods. This study provides findings that herbs may aid in decreasing the amount of salt consumers need to add for freshly prepared soups. It was also found that high levels of herbs may decrease consumers’ overall liking of soups. © 2014 Institute of Food Technologists®

  5. The magnetic field structure in high-mass star formation regions

    NASA Technical Reports Server (NTRS)

    Davidson, Jacqueline A.; Schleuning, D.; Dotson, J. L.; Dowell, C. Darren; Hildebrand, Roger H.

    1995-01-01

    We present a preliminary analysis of far-IR polarimetric observations, which were made to study the magnetic field structure in the high-mass star formation regions of M42, NGC2024, and W3. These observations were made from the Kuiper Airborne Observatory (KAO), using the University of Chicago far-IR polarimeter, Stokes.

  6. White light sunspot observations from the Solar Optical Universal Polarimeter on Spacelab-2

    NASA Technical Reports Server (NTRS)

    Shine, R. A.; Title, A. M.; Tarbell, T. D.; Topka, K. P.

    1987-01-01

    The flight of the Solar Optical Universal Polarimeter on Spacelab-2 provided the opportunity for the collection of time sequences of diffraction-limited (0.5 arcsec) solar images with excellent pointing stability (0.003 arcsec) and with freedom from the distortion that plagues ground-based images. A series of white-light images of active region 4682 were obtained on August 5, 1985, and the area containing the sunspot has been analyzed. These data have been digitally processed to remove noise and to separate waves from low-velocity material motions. The results include: (1) proper motion measurements of a radial outflow in the photospheric granulation pattern just outside the penumbra; (2) discovery of occasional bright structures ('streakers') that appear to be ejected outward from the penumbra; (3) broad dark 'clouds' moving outward in the penumbra, in addition to the well-known bright penumbral grains moving inward; (4) apparent extensions and contractions of penumbral filaments over the photosphere; and (5) observation of a faint bubble or looplike structure that seems to expand from two bright penumbral filaments into the photosphere.

  7. Optimal timing and frequency of bone marrow soup therapy for functional restoration of salivary glands injured by single-dose or fractionated irradiation.

    PubMed

    Fang, Dongdong; Shang, Sixia; Liu, Younan; Bakkar, Mohammed; Sumita, Yoshinori; Seuntjens, Jan; Tran, Simon D

    2018-02-01

    Injections of bone marrow (BM) cell extract, known as 'BM soup', were previously reported to mitigate ionizing radiation (IR) injury to salivary glands (SGs). However, the optimal starting time and frequency to maintain BM soup therapeutic efficacy remains unknown. This study tested the optimal starting time and frequency of BM soup injections in mice radiated with either a single dose or a fractionated dose. First, BM soup treatment was started at 1, 3 or 7 weeks post-IR; positive (non-IR) and negative (IR) control mice received injections of saline (vehicle control). Second, BM soup-treated mice received injections at different frequencies (1, 2, 3 and 5 weekly injections). Third, a 'fractionated-dose radiation' model to injure mouse SGs was developed (5 Gy × 5 days) and compared with the single high dose radiation model. All mice (n = 65) were followed for 16 weeks post-IR. The results showed that starting injections of BM soup between 1 and 3 weeks mitigated the effect of IR-induced injury to SGs and improved the restoration of salivary function. Although the therapeutic effect of BM soup lessens after 8 weeks, it can be sustained by increasing the frequency of weekly injections. Moreover, both single-dose and fractionated-dose radiation models are efficient and comparable in inducing SG injury and BM soup treatments are effective in restoring salivary function in both radiation models. In conclusion, starting injections of BM soup within 3 weeks post-radiation, with 5 weekly injections, maintains 90-100% of saliva flow in radiated mice. Copyright © 2017 John Wiley & Sons, Ltd.

  8. Soup consumption is associated with a lower dietary energy density and a better diet quality in US adults.

    PubMed

    Zhu, Yong; Hollis, James H

    2014-04-28

    Epidemiological studies have revealed that soup consumption is associated with a lower risk of obesity. Moreover, intervention studies have reported that soup consumption aids in body-weight management. However, little is known about mechanisms that can explain these findings. The objective of the present study was to investigate associations between soup consumption and daily energy intake, dietary energy density (ED), nutrient intake and diet quality. Adults aged 19-64 years who participated in the National Health and Nutrition Examination Surveys during 2003-8 were included in the study. Soup consumers were identified from the first dietary recall using the United States Department of Agriculture food codes and combination food type from the dietary data. Compared with non-consumers (n 9307), soup consumers (n 1291) had a lower body weight (P = 0.002), a lower waist circumference (P = 0.001) and a trend towards a lower total energy intake (P = 0.087). Soup consumption was associated with a lower dietary ED (P< 0.001); this was independent of whether data on beverage or water consumption were included. Diet quality, as measured by the Healthy Eating Index 2005, was significantly better in soup consumers (P = 0.008). Soup consumption was also associated with a reduced intake of total fat and an increased intake of protein, carbohydrate and dietary fibre, as well as several vitamins and minerals (P < 0.05 for all). However, it was also associated with a higher intake of Na (P < 0.001). The relationship between soup consumption and body weight could be due to a reduced dietary ED and an improved diet quality. Consumers need to pay attention to their Na intake and choose low-Na products for a healthier diet.

  9. Ingestion of onion soup high in quercetin inhibits platelet aggregation and essential components of the collagen-stimulated platelet activation pathway in man: a pilot study.

    PubMed

    Hubbard, Gary P; Wolffram, Siegfried; de Vos, Ric; Bovy, Arnaud; Gibbins, Jonathan M; Lovegrove, Julie A

    2006-09-01

    Epidemiological data suggest that those who consume a diet rich in quercetin-containing foods may have a reduced risk of CVD. Furthermore, in vitro and ex vivo studies have observed the inhibition of collagen-induced platelet activation by quercetin. The aim of the present study was to investigate the possible inhibitory effects of quercetin ingestion from a dietary source on collagen-stimulated platelet aggregation and signalling. A double-blind randomised cross-over pilot study was undertaken. Subjects ingested a soup containing either a high or a low amount of quercetin. Plasma quercetin concentrations and platelet aggregation and signalling were assessed after soup ingestion. The high-quercetin soup contained 69 mg total quercetin compared with the low-quercetin soup containing 5 mg total quercetin. Plasma quercetin concentrations were significantly higher after high-quercetin soup ingestion than after low-quercetin soup ingestion and peaked at 2.59 (sem 0.42) mumol/l. Collagen-stimulated (0.5 mug/ml) platelet aggregation was inhibited after ingestion of the high-quercetin soup in a time-dependent manner. Collagen-stimulated tyrosine phosphorylation of a key component of the collagen-signalling pathway via glycoprotein VI, Syk, was significantly inhibited by ingestion of the high-quercetin soup. The inhibition of Syk tyrosine phosphorylation was correlated with the area under the curve for the high-quercetin plasma profile. In conclusion, the ingestion of quercetin from a dietary source of onion soup could inhibit some aspects of collagen-stimulated platelet aggregation and signalling ex vivo. This further substantiates the epidemiological data suggesting that those who preferentially consume high amounts of quercetin-containing foods have a reduced risk of thrombosis and potential CVD risk.

  10. Frequency of soup intake is inversely associated with body mass index, waist circumference, and waist-to-hip ratio, but not with other metabolic risk factors in Japanese men.

    PubMed

    Kuroda, Motonaka; Ohta, Masanori; Okufuji, Tatsuya; Takigami, Chieko; Eguchi, Masafumi; Hayabuchi, Hitomi; Ikeda, Masaharu

    2011-01-01

    Several previous studies have shown that the intake of soup negatively correlates with the body mass index (BMI), serum cholesterol and triacylglycerol levels, and blood pressure, suggesting that soup intake reduces metabolic risk. However, the correlation between soup intake and various metabolic risk factors has not been well-established. Especially, it has not been investigated in Asian countries. The aim of this study was to investigate the association of the frequency of soup intake and metabolic risk factors such as BMI, waist circumference, waist-to-hip ratio, serum cholesterol, serum triacylglycerol, blood glucose, and glycated hemoglobin. A cross-sectional study of 103 Japanese men aged 24 to 75 years was conducted. The intake of soup and other food was investigated by semi-quantitative food frequency questionnaires. The correlation between the frequency of soup intake and metabolic risk factors was analyzed by multiple regression analysis with a linear model. The median value of frequency of soup intake was 7.0 times per week. After adjusting for confounding factors such as age, energy intake, energy from alcohol intake, current smoking, and estimated energy expenditure, the frequency of soup intake was found to have a significant inverse association with BMI (P=0.040), waist circumference (P=0.024), and waist-to-hip ratio (P=0.001). However, no significant associations with other metabolic risk factors were found. Frequency of soup intake is negatively correlated with obesity-related physical parameters in Japanese men. Copyright © 2011 American Dietetic Association. Published by Elsevier Inc. All rights reserved.

  11. Expected satiation after repeated consumption of low- or high-energy-dense soup.

    PubMed

    Hogenkamp, Pleunie S; Brunstrom, Jeffrey M; Stafleu, Annette; Mars, Monica; de Graaf, Cees

    2012-07-14

    We investigated whether repeated consumption of a low-energy-dense (LED; 208 kJ/100 g) or high-energy-dense (HED; 645 kJ/100 g) soup modifies expectations relating to the satiating capacity of the food, and its subsequent intake. In study 1, participants consumed either a novel-flavoured LED (n 32; 21 (SD 1·6) years, BMI 21·4 (SD 1·6) kg/m(2)) or HED soup (n 32; 21 (SD 1·6) years, BMI 21·3 (SD 1·7) kg/m(2)). Soup was served in a fixed amount on days 1-4 and ad libitum on day 5. 'Expected satiation' was measured on days 1, 2 and 5. Expected satiation did not change after repeated consumption of the LED or HED soup. Ad libitum intake did not differ between the LED (461 (SD 213) g) and HED soup (391 (SD 164) g). Only on day 1, expected satiation was higher for the HED soup than for the LED soup (P = 0·03), suggesting a role for sensory attributes in expected satiation. In study 2, thirty participants (21 (SD 1·6) years, BMI 21·3 (SD 1·7) kg/m(2)) performed a single measurement of expected satiation of the LED and HED soup, and four commercially available types of soup. Ratings on sensory attributes were associated with expected satiation. Results on expected satiation coincided with those of study 1. Thickness and intensity of taste were independently associated with expected satiation. Expectations may initially rely on sensory attributes and previous experiences, and are not easily changed.

  12. Dependency on soup kitchens in urban areas of New York State.

    PubMed Central

    Rauschenbach, B S; Frongillo, E A; Thompson, F E; Andersen, E J; Spicer, D A

    1990-01-01

    We studied the dependency of persons on soup kitchens in Albany, Buffalo, Rochester, Syracuse, and Westchester County, New York. Seventeen percent of the meal recipients were homeless, 62 percent lived in apartments or houses, 20 percent were working, 40 percent were women, and 17 percent had a child in their household. Fifty-nine percent started eating at the soup kitchen more than a year ago, and 51 percent ate five or more meals at soup kitchens in the last week. Most reported they came to the soup kitchen because of economic problems or lack of food; 93 percent had incomes below the poverty threshold. Most used some government food program; 48 percent received food stamps. Utilization of soup kitchens and other programs differed between men and women and between households with and without children. PMID:2293804

  13. Storage stability of cauliflower soup powder: The effect of lipid oxidation and protein degradation reactions.

    PubMed

    Raitio, Riikka; Orlien, Vibeke; Skibsted, Leif H

    2011-09-15

    Soups based on cauliflower soup powders, prepared by dry mixing of ingredients and rapeseed oil, showed a decrease in quality, as evaluated by a sensory panel, during the storage of the soup powder in the dark for up to 12weeks under mildly accelerated conditions of 40°C and 75% relative humidity. Antioxidant, shown to be effective in protecting the rapeseed bulk oil, used for the powder preparation, had no effect on storage stability of the soup powder. The freshly prepared soup powder had a relatively high concentration of free radicals, as measured by electron spin resonance spectroscopy, which decreased during storage, and most remarkably during the first two weeks of storage, with only marginal increase in lipid hydroperoxides as primary lipid oxidation products, and without any increase in secondary lipid oxidation products. Analyses of volatiles by SPME-GC-MS revealed a significant increase in concentrations of 2-methyl- and 3-methyl butanals, related to Maillard reactions, together with an increase in 2-acetylpyrrole concentration. The soup powders became more brown during storage, as indicated by a decreasing Hunter L-value, in accord with non-enzymatic browning reactions. A significant increase in the concentrations of dimethyl disulfide in soup powder headspace indicated free radical-initiated protein oxidation. Protein degradation, including Maillard reactions and protein oxidation, is concluded to be more important than lipid oxidation in determining the shelf-life of dry cauliflower soup powder. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. Reduction of sodium content in spicy soups using monosodium glutamate

    PubMed Central

    Jinap, Selamat; Hajeb, Parvaneh; Karim, Roslina; Norliana, Sarian; Yibadatihan, Simayi; Abdul-Kadir, Razak

    2016-01-01

    Background Excessive dietary sodium intake causes several diseases, such as hypertension, cardiovascular and renal disease, etc. Hence, reducing sodium intake has been highly recommended. In this study the effect of monosodium glutamate (MSG), as an umami substance, on saltiness and sodium reduction was investigated. Methods and Results The trained panellists were presented with basic spicy soups (curry chicken and chili chicken) containing different amounts of sodium chloride (NaCl) (0–1.2%) and MSG (0–1.2%). They tasted the optimum concentrations of NaCl and MSG for the two spicy soups and the overall acceptability were 0.8% and 0.7%, respectively. There was no significant effect of spiciness level on the saltiness and umami taste of both soups. The optimum levels of combined NaCl and MSG for overall acceptance in the chili and curry soups were 0.3% and 0.7%, respectively. The results showed that with the addition of MSG, it is possible to reduce sodium intake without changing the overall acceptability of the spicy soup. A 32.5% reduction in sodium level is made feasible by adding 0.7% MSG to the spicy soups. Conclusions This study suggests that low-sodium soups can be developed by the addition of appropriate amounts of MSG, while maintaining the acceptability of the spicy soups. It was also proven that it is feasible to reduce sodium intake by replacing NaCl with MSG. PMID:27356909

  15. The X-Ray Polarimeter Instrument on Board the Polarimeter for Relativistic Astrophysical X-Ray Sources (PRAXyS) Mission

    NASA Technical Reports Server (NTRS)

    Hill, J. E.; Black, J. K.; Jahoda, K.; Tamagawa, T.; Iwakiri, W.; Kitaguchi, T.; Kubota, M.; Kaaret, P.; Mccurdy, R.; Miles, D. M.; hide

    2016-01-01

    The Polarimeter for Relativistic Astrophysical X-ray Sources (PRAXyS) is one of three Small Explorer (SMEX) missions selected by NASA for Phase A study. The PRAXyS observatory carries an X-ray Polarimeter Instrument (XPI) capable of measuring the linear polarization from a variety of high energy sources, including black holes, neutron stars, and supernova remnants. The XPI is comprised of two identical mirror-Time Projection Chamber (TPC) polarimeter telescopes with a system effective area of 124 sq cm at 3 keV, capable of photon limited observations for sources as faint as 1 mCrab. The XPI is built with well-established technologies. This paper will describe the performance of the XPI flight mirror with the engineering test unit polarimeter

  16. An All Silicon Feedhorn-Coupled Focal Plane for Cosmic Microwave Background Polarimetry

    NASA Technical Reports Server (NTRS)

    Hubmayr, J.; Appel, J. W.; Austermann, J. E.; Beall, J. A.; Becker, D.; Benson, B. A.; Bleem, L. E.; Carlstrom, J. E.; Chang, C. L.; Cho, H. M.; hide

    2011-01-01

    Upcoming experiments aim to produce high fidelity polarization maps of the cosmic microwave background. To achieve the required sensitivity, we are developing monolithic, feedhorn-coupled transition edge sensor polarimeter arrays operating at 150 GHz. We describe this focal plane architecture and the current status of this technology, focusing on single-pixel polarimeters being deployed on the Atacama B-mode Search (ABS) and an 84-pixel demonstration feedhorn array backed by four 10-pixel polarimeter arrays. The feedhorn array exhibits symmetric beams, cross-polar response less than -23 dB and excellent uniformity across the array. Monolithic polarimeter arrays, including arrays of silicon feedhorns, will be used in the Atacama Cosmology Telescope Polarimeter (ACTPol) and the South Pole Telescope Polarimeter (SPTpol) and have been proposed for upcoming balloon-borne instruments.

  17. Effect of cooking temperatures on protein hydrolysates and sensory quality in crucian carp (Carassius auratus) soup.

    PubMed

    Zhang, Jinjie; Yao, Yanjia; Ye, Xingqian; Fang, Zhongxiang; Chen, Jianchu; Wu, Dan; Liu, Donghong; Hu, Yaqin

    2013-06-01

    Cooking methods have a significant impact on flavour compounds in fish soup. The effects of cooking temperatures (55, 65, 75, 85, 95, and 100 °C) on sensory properties and protein hydrolysates were studied in crucian carp (Carassius auratus) soup. The results showed that the soup prepared at 85 °C had the best sensory quality in color, flavour, amour, and soup pattern. Cooking temperature had significant influence on the hydrolysis of proteins in the soup showed by SDS-PAGE result. The contents of water soluble nitrogen (WSN) and non-protein nitrogen (NPN) increased with the cooking temperature, but the highest contents of total peptides and total free amino acids (FAA) were obtained at the cooking temperature of 85 °C. The highest contents of umami-taste active amino acid and branched-chain amino acids were also observed in the 85 °C sample. In conclusion, a cooking temperature of 85 °C was preferred for more excellent flavor and higher nutritional value of crucian carp soup.

  18. Protein-enhanced soups: a consumer-accepted food for increasing dietary protein provision among older adults.

    PubMed

    Donahue, Elizabeth; Crowe, Kristi Michele; Lawrence, Jeannine

    2015-02-01

    Protein-enhanced soups (PES) may improve protein intake among older adults. This study examined sensory attributes (aroma, texture, taste, and overall acceptability) and preferences of PES (chicken noodle and cheddar broccoli) compared with flavor-matched control soups (FCS) among older adults (≥65 years) and evaluated dietary profile changes of a standard menu based on the substitution of one PES serving/d for a standard soup. Modified paired preference tests and 5-point facial hedonic scales were administered to participants (n = 44). No significant differences in sensory attributes between either PES compared with FCS were identified, but significant gender- and age-related differences (p < 0.05) were observed. About Sixty-one percent of participants preferred protein-enhanced chicken noodle soup while only 38% preferred protein-enhanced cheddar broccoli soup to their respective FCS. Substituting one PES serving for one non-fortified soup serving per day resulted in significantly higher (p < 0.001) protein profile. Results suggest that all attributes of PES were consistent with sensory expectations and PES substitution could improve protein provision.

  19. [Study on the liver-protective and choleretic effect of zhizi baipi soup and its disassembled prescription].

    PubMed

    Xiao, Xu; Zhu, Ji-Xiao; Luo, Guang-Ming; Li, Lei; Zhu, Yu-Ye; Zeng, Jin-Xiang; Wang, Xiao-Yun; Wu, Bo

    2013-07-01

    To investigate the effect of Zhizi Baipi soup and its disassembled prescription on protecting liver and improving choleresis and explore the regularity of Zhizi Baipi soup composition. The model of mouse liver injury induced by carbon tetraehlofide (CCl4) was used to observe the effects of Zhizi Baipi soup and its disassembled prescription by oral adminstration, the bile volume was determinied by common bile duct drainage. Zhizi Baipi soup and each treatment group with gardenia could significantly inhibit the increased serum ATL and AST activities, reduce liver MDA level, and significantly promote the bile flow and bilirubin in bile in normal rats. Zhizi Baipi soup has effects on protecting liver and increasing bile secretion, its monarch drug, gardenia plays an important role in the decoction, the effect of eliminating dampness and heat are mainly ascribed to the synergic effect of gardenia and phellodendron.

  20. Effects of point massage of liver and stomach channel combined with pith and trotter soup on postpartum lactation start time.

    PubMed

    Luo, Qiong; Hu, Yin; Zhang, Hui

    2017-10-01

    Delay in lactation initiation causes maternal anxiety and subsequent adverse impact on maternal exclusive breast feeding. It is important to explore a safe and convenient way to promote lactation initiation. The feasibility of point massage of liver and stomach channel combined with pith and trotter soup on prevention of delayed lactation initiation was investigated in the present study. 320 women were enrolled and randomly divided into four groups, control group (80 women), point massage group (80 women), pith and trotter soup group (80 women), and massage + soup group (80 women) to compare the lactation initiation time. We found that women in point massage group, pith and trotter soup group and massage + soup group had earlier initiation of lactation compared with control group. Women in massage + soup group had the earliest initiation time of lactation. There were significant differences between massage + soup group and pith and trotter soup group. But, there were no significant differences between massage + soup group and massage group. We conclude that point massage of the liver and stomach channel is easy to operate and has the preventive effect on delayed lactation initiation. Impact statement What is already known on this subject: Initiation of lactation is a critical period in postpartum milk secretion. Delays in lactation initiation lead to maternal anxiety and have an adverse impact on maternal exclusive breastfeeding. Sucking frequently by babies and mammary massage might be effective but insufficient for delayed lactation initiation. What the results of this study add: We found in the present study that lactation initiation is significantly earlier in women receiving routine nursing combined with point massage of liver and stomach channel, or pith trotters soup, or massage of liver and stomach channel with pith and trotters soup than in a control group receiving routine nursing. These three methods are all effective, while the most effective method is point massage combined with pith trotter soup. There was no maternal drug allergy, postpartum bleeding or other adverse reactions noted in all women. What the implications are of these findings for clinical practice and/or further research: The present study suggested that the application of point massage in clinic might be useful for preventing lack of milk postpartum by delayed lactation initiation and improving the exclusive breastfeeding rate. Further research might explore that molecular mechanism of lactation promotion by point massage using blood samples or animal models.

  1. Pediatric soup scald burn injury: etiology and prevention.

    PubMed

    Palmieri, Tina L; Alderson, Tyrone S; Ison, Dahlia; O'Mara, Michael S; Sharma, Raj; Bubba, Anthony; Coombs, Elena; Greenhalgh, David G

    2008-01-01

    One of the leading causes of scald burn injury in children is from hot soup, particularly prepackaged instant soups. The purpose of this study was to determine the demographic, socioeconomic, and situational factors that contribute to the incidence of scald burns in children. A 20-item questionnaire was given to the caregiver of children who were treated for scald burn injury at a pediatric burn center from July 2006 to March 2007. Questions included demographics (child age, gender, siblings, ethnicity), socioeconomic status (income, education), factors contributing to the injury (type of soup, child supervision, type of container), and location of injury. The mean age of the 78 children sustaining burn injury and completing the survey was 4.8 +/- 0.6 years. The majority of patients were girls (51%), and the most frequently involved ethnic group was Hispanic (44%). Households had a mean of 3.0 +/- 0.3 children in residence, and an income of less than $29,000/year (59%). The highest educational level achieved was high school for 73% of the parents. Prepackaged soup (65%) with a narrow base heated directly in the original container (46%) using the microwave (51%) was implicated in the majority of burns. Soup scald burns, especially from prepackaged instant soups, appear to predominate in lower income families with multiple children. The majority of injuries occur when the caregiver heats the soup in the original container using the microwave. Prevention of these types of injuries will require a two-pronged approach: educating families with multiple children and changing the soup packaging.

  2. Taking the Measure of the Universe

    NASA Technical Reports Server (NTRS)

    Hinshaw, Gary

    2009-01-01

    The cosmic microwave background (CMB) radiation is the oldest light in the universe - it is literally the remnant heat left over from the Big Bang. This fossil relic has survived largely intact and it provides us with a unique probe of conditions in the early universe, long before any stars or galaxies had formed. NASA has now flown two satellites devoted to studying the CMB: 'COBE' and 'WMAP'. In this lecture I will describe what we have learned from these missions including: evidence for the Big Bang itself; new measurements of the age, shape, and content of the universe; and new evidence that all structure in the universe emerged from microscopic quantum fluctuations in the primordial soup.

  3. Multi-angle polarimeter inter-comparison: the PODEX and ACEPOL field campaigns

    NASA Astrophysics Data System (ADS)

    Knobelspiesse, K. D.; Tan, Q.; Redemann, J.; Cairns, B.; Diner, D. J.; Ferrare, R. A.; van Harten, G.; Hasekamp, O. P.; Kalashnikova, O. V.; Martins, J. V.; Yorks, J. E.; Seidel, F. C.

    2017-12-01

    A multi-angle polarimeter has been proposed for the NASA Aerosol-Cloud-Ecosystem (ACE) mission, recommended by the National Research Council's Decadal Survey. Such instruments are uncommon in orbit, and there is a great diversity of prototype instrument characteristics. For that reason, NASA funded two field campaigns where airborne polarimeter prototypes were deployed on the high altitude ER-2 aircraft. The first field campaign, POlarimeter DEfinition EXperiment (PODEX), was carried out in southern California in early 2013. Three polarimeters participated: the Airborne Multi-angle SpectroPolarimeter Imager (AirMSPI), the Passive Aerosol and Cloud Suite (PACS) and the Research Scanning Polarimeter (RSP). PACS, on its first deployment, suffered detector problems, while AirMSPI and RSP performed within expectations. Initial comparisons of AirMSPI and RSP observations found Degree of Linear Polarization (DoLP) biases. Following corrections to both instrument's calibration and/or geolocation techniques, these issues have improved. We will present the details of this comparison. The recent ACEPOL mission returned to southern California in October-November with a larger compliment of multi-angle polarimeters. This included AirMSPI and RSP, like in PODEX. Additional polarimetric instruments included AirHARP (Airborne HyperAngular Rainbow Polarimeter, a successor to PACS) and SPEX Airborne (SPectropolarimeter for Planetary Exploration). Two Lidars were also deployed: The High Spectral Resolution Lidar -2 (HSRL-2) and the Cloud Physics Lidar (CPL). While data processing is still underway, we will describe the objectives of this campaign and give a preview of what to expect in subsequent analysis.

  4. Utilization of modified starch from avocado (Persea americana Mill.) seed in cream soup production

    NASA Astrophysics Data System (ADS)

    Cornelia, M.; Christianti, A.

    2018-01-01

    Avocado (Persea americana Mill.) seed was often seen as waste and underutilized resources, especially in the food industry. The aim of this research was to modify the structure of avocado seed starch using the cross-linking method, to improve the viscosity stability in the cream soup. In the preliminary research, starch was isolated from the seed and modified by STPP (sodium tripolyphosphate) with 2%, 4%, and 6% concentration and were reacted for 1, 2, and 3 hours. Starches were analyzed for moisture and ash content, paste clarity, gel strength, swelling power, solubility, yield, and degree of whiteness. Based on the analysis results, the best reaction time and STPP concentration was 6% at 1 hour reaction time. Native starch and the best-modified starch were applied in the cream soup and compared with commercial cream soup. Cream soups were analyzed for viscosity stability using viscometer in 0, 1, 3, and 5 hours after storage in room temperature. The result showed that cream soup using modified starch has better viscosity stability than native starch and commercial cream soup after 5 hours storage, which was 181.7 ± 4.85 cP. Sensory analysis showed that cream soup using modified starch was more acceptable than the others. Avocado seed modified starch has phosphate group that strengthen the starch chain to prevent viscosity breakdown.

  5. Impacts of glutathione Maillard reaction products on sensory characteristics and consumer acceptability of beef soup.

    PubMed

    Hong, J H; Jung, D W; Kim, Y S; Lee, S M; Kim, K O

    2010-10-01

    The sensory characteristics and consumer acceptability of beef soup with added glutathione Maillard reaction products (GMRPs) were investigated to examine the effects of the GMRPs on beef-soup flavor compared to soups made with glutathione (GSH) and monosodium glutamate (MSG), a control (CON), or a control soup made with 150% beef content (CON150). The sensory characteristics of the beef soups were examined by descriptive analysis. The overall acceptabilities of the beef soups were rated by consumers. Principal component analysis was performed on descriptive data as explanatory variables with overall acceptability as a supplementary variable to observe the relationships between the descriptive data and consumer acceptability, as well as the relationships between the beef-soup samples and their sensory attributes. The samples containing GMRPs had "beef flavor" that was stronger than the CON and MSG samples, and comparable to that of the GSH sample and CON150. The GMRP samples had stronger "green onion flavor,"garlic flavor," and "boiled egg white flavor" than the other samples. The beef soup containing MSG was preferred to CON, CON150, and GSH. The samples with GMRPs were least favored because of their pronounced metallic and astringent notes. The results of this study imply the feasibility of GMRPs as a flavor enhancer since the soups containing these compounds showed more complex flavor profiles than GSH. However, future studies are required to optimize the MR conditions that produce GMRPs without undesirable characteristics. Practical Application: This study examined the practicability of the Maillard reaction products between glutathione (GSH) and glucose (GP) or fructose (FP) as a flavor enhancer by investigating the sensory characteristics and consumer acceptability evoked by them in a beef-soup system. This study helps flavor and food industry to develop a new flavor enhancer by providing practical information, such as beef flavor-enhancing effect of FP and GP compared to that by increasing beef content or adding GSH or MSG. In addition, it is expected that the outcome of this study, such as sensory attributes of and consumer responses to GSH Maillard reaction products, compliments previous studies that mostly focused on chemical analysis of Maillard reaction.

  6. Managing Chemotherapy Side Effects: Appetite Changes

    MedlinePlus

    ... up on liquids during meals. ● ● Drink milkshakes or soups that are easy to swallow. ● ● Keep track of ... drinks that are high in calories or protein. Soups Drinks Main meals and snacks Sweets ••Cream soups •• ...

  7. Construction Status and Early Science with the Daniel K. Inouye Solar Telescope

    NASA Astrophysics Data System (ADS)

    McMullin, Joseph P.; Rimmele, Thomas R.; Warner, Mark; Martinez Pillet, Valentin; Craig, Simon; Woeger, Friedrich; Tritschler, Alexandra; Berukoff, Steven J.; Casini, Roberto; Goode, Philip R.; Knoelker, Michael; Kuhn, Jeffrey Richard; Lin, Haosheng; Mathioudakis, Mihalis; Reardon, Kevin P.; Rosner, Robert; Schmidt, Wolfgang

    2016-05-01

    The 4-m Daniel K. Inouye Solar Telescope (DKIST) is in its seventh year of overall development and its fourth year of site construction on the summit of Haleakala, Maui. The Site Facilities (Utility Building and Support & Operations Building) are in place with ongoing construction of the Telescope Mount Assembly within. Off-site the fabrication of the component systems is completing with early integration testing and verification starting.Once complete this facility will provide the highest sensitivity and resolution for study of solar magnetism and the drivers of key processes impacting Earth (solar wind, flares, coronal mass ejections, and variability in solar output). The DKIST will be equipped initially with a battery of first light instruments which cover a spectral range from the UV (380 nm) to the near IR (5000 nm), and capable of providing both imaging and spectro-polarimetric measurements throughout the solar atmosphere (photosphere, chromosphere, and corona); these instruments are being developed by the National Solar Observatory (Visible Broadband Imager), High Altitude Observatory (Visible Spectro-Polarimeter), Kiepenheuer Institute (Visible Tunable Filter) and the University of Hawaii (Cryogenic Near-Infrared Spectro-Polarimeter and the Diffraction-Limited Near-Infrared Spectro-Polarimeter). Further, a United Kingdom consortium led by Queen's University Belfast is driving the development of high speed cameras essential for capturing the highly dynamic processes measured by these instruments. Finally, a state-of-the-art adaptive optics system will support diffraction limited imaging capable of resolving features approximately 20 km in scale on the Sun.We present the overall status of the construction phase along with the current challenges as well as a review of the planned science testing and the transition into early science operations.

  8. Effect of preexercise soup ingestion on water intake and fluid balance during exercise in the heat.

    PubMed

    Johannsen, Neil M; Sullivan, Zebblin M; Warnke, Nicole R; Smiley-Oyen, Ann L; King, Douglas S; Sharp, Rick L

    2013-06-01

    To determine whether chicken noodle soup before exercise increases ad libitum water intake, fluid balance, and physical and cognitive performance compared with water. Nine trained men (age 25 ± 3 yr, VO2peak 54.2 ± 5.1 ml · kg-1 · min-1; M ± SD) performed cycle exercise in the heat (wet bulb globe temperature = 25.9 ± 0.4 °C) for 90 min at 50% VO2peak, 45 min after ingesting 355 ml of either commercially available bottled water (WATER) or chicken noodle soup (SOUP). The same bottled water was allowed ad libitum throughout both trials. Participants then completed a time trial to finish a given amount of work (10 min at 90% VO2peak; n = 8). Cognitive performance was evaluated by the Stroop color-word task before, every 30 min during, and immediately after the time trial. Ad libitum water intake throughout steady-state exercise was greater in SOUP than with WATER (1,435 ± 593 vs. 1,163 ± 427 g, respectively; p < .03). Total urine volume was similar in both trials (p = .13), resulting in a trend for greater water retention in SOUP than in WATER (87.7% ± 7.6% vs. 74.9% ± 21.7%, respectively; p = .09), possibly due to a change in free water clearance (-0.32 ± 1.22 vs. 0.51 ± 1.06 ml/min, respectively; p = .07). Fluid balance tended to be improved with SOUP (-106 ± 603 vs. -478 ± 594 g, p = .05). Likewise, change in plasma volume tended to be reduced in SOUP compared with WATER (p = .06). Only mild dehydration was achieved (<1%), and physical performance was not different between treatments (p = .77). The number of errors in the Stroop color-word task was lower in SOUP throughout the entire trial (treatment effect; p = .04). SOUP before exercise increased ad libitum water intake and may alter kidney function.

  9. Quantitative analysis of protein and gene expression in salivary glands of Sjogren's-like disease NOD mice treated by bone marrow soup.

    PubMed

    Misuno, Kaori; Tran, Simon D; Khalili, Saeed; Huang, Junwei; Liu, Younan; Hu, Shen

    2014-01-01

    Bone marrow cell extract (termed as BM Soup) has been demonstrated to repair irradiated salivary glands (SGs) and restore saliva secretion in our previous study. In the present study, we aim to investigate if the function of damaged SGs in non-obese diabetic (NOD) mice can be restored by BM Soup treatment and the molecular alterations associated with the treatment. Whole BM cells were lysed and soluble intracellular contents ("BM Soup") were injected I.V. into NOD mice. Tandem mass tagging with 2-D liquid chromatography-mass spectrometry was used to quantify proteins in the submandibular glands (SMGs) between untreated and BM Soup-treated mice. Quantitative PCR was used to identify genes with altered expression in the treated mice. restored salivary flow rates to normal levels and significantly reduced the focus scores of SMGs in NOD mice. More than 1800 proteins in SMG cells were quantified by the proteomic approach. Many SMG proteins involved in inflammation and apoptosis were found to be down-regulated whereas those involved in salivary gland biology and development/regeneration were up-regulated in the BM Soup-treated mice. qPCR analysis also revealed expression changes of growth factors and cytokines in the SMGs of the treated NOD mice. BM Soup treatment is effective to restore the function of damaged SGs in NOD mice. Through gene/protein expression analysis, we have found that BM Soup treatment might effectuate via inhibiting apoptosis, focal adhesion and inflammation whereas promoting development, regeneration and differentiation of the SG cells in NOD mice. These findings provide important insights on the potential mechanisms underlying the BM Soup treatment for functional restoration of damaged SGs in NOD mice. Additional studies are needed to further confirm the identified target genes and their related signaling pathways that are responsible for the BM Soup treatment.

  10. Quantitative Analysis of Protein and Gene Expression in Salivary Glands of Sjogren’s-Like Disease NOD Mice Treated by Bone Marrow Soup

    PubMed Central

    Misuno, Kaori; Khalili, Saeed; Huang, Junwei; Liu, Younan

    2014-01-01

    Background Bone marrow cell extract (termed as BM Soup) has been demonstrated to repair irradiated salivary glands (SGs) and restore saliva secretion in our previous study. In the present study, we aim to investigate if the function of damaged SGs in non-obese diabetic (NOD) mice can be restored by BM Soup treatment and the molecular alterations associated with the treatment. Methods Whole BM cells were lysed and soluble intracellular contents (“BM Soup”) were injected I.V. into NOD mice. Tandem mass tagging with 2-D liquid chromatography-mass spectrometry was used to quantify proteins in the submandibular glands (SMGs) between untreated and BM Soup-treated mice. Quantitative PCR was used to identify genes with altered expression in the treated mice. Results BM Soup restored salivary flow rates to normal levels and significantly reduced the focus scores of SMGs in NOD mice. More than 1800 proteins in SMG cells were quantified by the proteomic approach. Many SMG proteins involved in inflammation and apoptosis were found to be down-regulated whereas those involved in salivary gland biology and development/regeneration were up-regulated in the BM Soup-treated mice. qPCR analysis also revealed expression changes of growth factors and cytokines in the SMGs of the treated NOD mice. Conclusion BM Soup treatment is effective to restore the function of damaged SGs in NOD mice. Through gene/protein expression analysis, we have found that BM Soup treatment might effectuate via inhibiting apoptosis, focal adhesion and inflammation whereas promoting development, regeneration and differentiation of the SG cells in NOD mice. These findings provide important insights on the potential mechanisms underlying the BM Soup treatment for functional restoration of damaged SGs in NOD mice. Additional studies are needed to further confirm the identified target genes and their related signaling pathways that are responsible for the BM Soup treatment. PMID:24489858

  11. The Hottest, and Most Liquid, Liquid in the Universe

    NASA Astrophysics Data System (ADS)

    Rajagopal, Krishna

    2012-03-01

    What was the universe like microseconds after the big bang? At very high temperatures, protons and neutrons fall apart --- the quarks that are ordinarily confined within them are freed. Before experiments at the Relativistic Heavy Ion Collider started recreating little droplets of big bang matter, it was thought to be a tenuous gas-like plasma. Now we know from experiments at RHIC and at the Large Hadron Collider that at these extreme temperatures nature serves up hot quark soup --- the hottest liquid in the universe and the liquid that flows with the least dissipation. The only other comparably liquid liquid is the coldest liquid in the universe, namely the fluid made of trapped fermionic atoms at microKelvin rather than TeraKelvin temperatures. These are two examples of strongly coupled fluids without any apparent quasiparticle description, a feature that they share with other phases of matter like the strange metal phase of the cuprate superconductors that aren't conventionally thought of as liquids but that are equally challenging to understand. I will describe how physicists are using RHIC and LHC experiments --- as well as calculations done using dualities between liquids and black holes discovered in string theory --- to discern the properties of hot quark soup. In this domain, string theory is answering questions posed by laboratory experiments. I will describe the opportunities and challenges for coming experiments at RHIC and the LHC, chief among them being understanding how a liquid with no apparent particulate description emerges from quarks and gluons.

  12. LWIR Snapshot Imaging Polarimeter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dr. Robert E Sampson

    This report describes the results of a phase 1 STTR to design a longwave infrared imaging polarimeter. The system design, expected performance and components needed to construct the imaging polarimeter are described. Expected performance is modeled and sytem specifications are presented.

  13. Motivational Interviewing to Increase Physical Activity in Breast Cancer Survivors

    DTIC Science & Technology

    2011-05-01

    1 cup 9. Over the last month, how often did you eat vegetable soups? Include tomato soup, gazpacho, beef with vegetable soup, minestrone soup, and...than $ 10,000 --2 $10,000-$19,999 --3 $20,000- $ 39,999 Are you currently on hormonal therapy? 12. If YES, what do you take? 1 Tamoxifen __ 4...know 15. Have you received any hormone replacement therapy within the past week (i.e., estrogen)? __ 1 No __ 2 Yes __ 3 Don’t know 16. Have you

  14. Polarimetric survey of main-belt asteroids. IV. New results from the first epoch of the CASLEO survey

    NASA Astrophysics Data System (ADS)

    Gil-Hutton, R.; Cellino, A.; Bendjoya, Ph.

    2014-09-01

    Aims: We present results of a polarimetric survey of main-belt asteroids at Complejo Astronómico El Leoncito (CASLEO), San Juan, Argentina. The aims of this survey are to increase the database of asteroid polarimetry, to estimate diversity in polarimetric properties of asteroids that belong to different taxonomic classes, and to search for objects that exhibit anomalous polarimetric properties. Methods: The data were obtained using the Torino and CASPROF polarimeters at the 2.15m telescope. The Torino polarimeter is an instrument that allows simultaneous measurement of polarization in five different bands, and the CASPROF polarimeter is a two-hole aperture polarimeter with rapid modulation. Results: The survey began in 1995, and until 2012 data on a large sample of asteroids were obtained. We here present and analyze the unpublished results for 129 asteroids of different taxonomic types, 56 which were polarimetrically observed for the first time. We find that the asteroids (402) Chloe and (729) Watsonia are Barbarians, and asteroid (269) Justitia shows a phase - polarization curve that seems to have a small inversion angle. Data obtained in UBVRI colors allow us to sketch an analysis of the wavelength dependence of the degree of linear polarization for 31 asteroids, in spite of some large error bars in some cases. Based on observations carried out at the Complejo Astronómico El Leoncito, operated under agreement between the Consejo Nacional de Investigaciones Científicas y Técnicas de la República Argentina and the National Universities of La Plata, Córdoba, and San Juan.Table 1 is only available at the CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (ftp://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/569/A122

  15. Calibration and Compensation of Instrumental Errors in Imaging Polarimeters

    DTIC Science & Technology

    2007-04-01

    procedures for polarimeters 3. Examine impact of focal plane nonuniformity on polarimeters 4. Understand the role of bandwidth in broadband polarimetry. 5... nonuniformity (NU) noise. NU noise is a results from pixel-to-pixel variations in the photodetector response. NU noise is a persistent problem for all... nonuniformity noise in imaging polarimeters," Proc SPIE Vol. 5888: Polarization Science and Remote Sensing 11, pp. 58880J 1 - 10, J. A. Shaw and J. S

  16. High-Sensitivity X-ray Polarimetry with Amorphous Silicon Active-Matrix Pixel Proportional Counters

    NASA Technical Reports Server (NTRS)

    Black, J. K.; Deines-Jones, P.; Jahoda, K.; Ready, S. E.; Street, R. A.

    2003-01-01

    Photoelectric X-ray polarimeters based on pixel micropattern gas detectors (MPGDs) offer order-of-magnitude improvement in sensitivity over more traditional techniques based on X-ray scattering. This new technique places some of the most interesting astronomical observations within reach of even a small, dedicated mission. The most sensitive instrument would be a photoelectric polarimeter at the focus of 2 a very large mirror, such as the planned XEUS. Our efforts are focused on a smaller pathfinder mission, which would achieve its greatest sensitivity with large-area, low-background, collimated polarimeters. We have recently demonstrated a MPGD polarimeter using amorphous silicon thin-film transistor (TFT) readout suitable for the focal plane of an X-ray telescope. All the technologies used in the demonstration polarimeter are scalable to the areas required for a high-sensitivity collimated polarimeter. Leywords: X-ray polarimetry, particle tracking, proportional counter, GEM, pixel readout

  17. Deepest Trenching at Phoenix Site on Mars

    NASA Technical Reports Server (NTRS)

    2008-01-01

    NASA's Phoenix Mars Lander widened the deepest trench it has excavated, dubbed 'Stone Soup,' (in the lower half of this image) to collect a sample from about 18 centimeters (7 inches) below the surface for analysis by the lander's wet chemistry laboratory.

    Phoenix's Surface Stereo Imager took this image on Sol 95 (Aug. 30, 2008), the 95th Martian day since landing. For scale, the rock to the right of the Stone Soup trench is about 15 centimeters (6 inches) across. The lander's robotic arm scooped up a sample from the left half of the trench for delivery the following sol to the wet chemistry laboratory.

    The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  18. Paracrine effects of bone marrow soup restore organ function, regeneration, and repair in salivary glands damaged by irradiation.

    PubMed

    Tran, Simon D; Liu, Younan; Xia, Dengsheng; Maria, Ola M; Khalili, Saeed; Wang, Renee Wan-Jou; Quan, Vu-Hung; Hu, Shen; Seuntjens, Jan

    2013-01-01

    There are reports that bone marrow cell (BM) transplants repaired irradiated salivary glands (SGs) and re-established saliva secretion. However, the mechanisms of action behind these reports have not been elucidated. To test if a paracrine mechanism was the main effect behind this reported improvement in salivary organ function, whole BM cells were lysed and its soluble intracellular contents (termed as "BM Soup") injected into mice with irradiation-injured SGs. The hypothesis was that BM Soup would protect salivary cells, increase tissue neovascularization, function, and regeneration. Two minor aims were also tested a) comparing two routes of delivering BM Soup, intravenous (I.V.) versus intra-glandular injections, and b) comparing the age of the BM Soup's donors. The treatment-comparison group consisted of irradiated mice receiving injections of living whole BM cells. Control mice received irradiation and injections of saline or sham-irradiation. All mice were followed for 8 weeks post-irradiation. BM Soup restored salivary flow rates to normal levels, protected salivary acinar, ductal, myoepithelial, and progenitor cells, increased cell proliferation and blood vessels, and up-regulated expression of tissue remodeling/repair/regenerative genes (MMP2, CyclinD1, BMP7, EGF, NGF). BM Soup was as an efficient therapeutic agent as injections of live BM cells. Both intra-glandular or I.V. injections of BM Soup, and from both young and older mouse donors were as effective in repairing irradiated SGs. The intra-glandular route reduced injection frequency/dosage by four-fold. BM Soup, which contains only the cell by-products, can be advantageously used to repair irradiation-damaged SGs rather than transplanting whole live BM cells which carry the risk of differentiating into unwanted/tumorigenic cell types in SGs.

  19. Professors, Administrators at U. of Portland Get a Firsthand Look at Services to City's Poor.

    ERIC Educational Resources Information Center

    Monaghan, Peter

    1987-01-01

    Professors and staff members of the University of Portland took the "urban plunge" when they visited the state's Adult and Family Services offices, shelters for the homeless and for battered women, an alcohol- and drug-rehabilitation center, and served lunch at two soup kitchens. A project at Notre Dame is also described. (MLW)

  20. The State of the South 2007: Philanthropy as the South's "Passing Gear". State of the South

    ERIC Educational Resources Information Center

    MDC, Inc., 2007

    2007-01-01

    The South is arguably the most generous region of a generous nation. Southerners give to their universities and schools, to their soup kitchens and homeless shelters, to the community United Way, to relief agencies responding to natural disasters, and most specially to their churches and other religious institutions. As a whole, Southerners give…

  1. Confronting Ambiguity, Anarchy, and Crisis in Institutional Research: Using Student Unit Record Databases in Extra-Institutional Research

    ERIC Educational Resources Information Center

    Musoba, Glenda D.; Gross, Jacob P. K.; Hossler, Don

    2008-01-01

    The world of policymaking on the campuses of colleges and universities is messy, ambiguous, and contested. In this complex environment, which Kingdon (2003) has aptly called a "policy soup," the role of institutional research is often not only to provide answers to existing policy questions but to produce information to help transform…

  2. 7 CFR 251.3 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... following categories: (i) Emergency feeding organizations (including food banks, food pantries and soup... of food or edible commodities, or the products of food or edible commodities, to food pantries, soup... into an agreement with the United States Department of Agriculture under § 251.2(c). (j) Soup kitchen...

  3. Moose soup shigellosis in Alaska.

    PubMed Central

    Gessner, B D; Beller, M

    1994-01-01

    Following a community gathering held in early September 1991, an outbreak of gastroenteritis occurred in Galena, Alaska. We conducted an epidemiologic investigation to determine the cause of the outbreak. A case of gastroenteritis was defined as diarrhea or at least 2 other symptoms of gastrointestinal illness occurring in a Galena resident within a week of the gathering. Control subjects included asymptomatic residents who either resided with an affected person or were contacted by us during a telephone survey. Of 25 case-patients, 23 had attended the gathering compared with 33 of 58 controls. Among persons who attended the gathering and from whom we obtained a food consumption history, 17 of 19 case-patients and 11 of 22 controls ate moose soup. No other foods served at the gathering were associated with illness. Ten case-patients had culture-confirmed Shigella sonnei. Many pots of moose soup were served each day, and persons attended the gathering and ate moose soup on more than 1 day. Moose soup was prepared in private homes, allowed to cool, and usually served the same day. We identified 5 women who had prepared soup for the gathering and in whose homes at least 1 person had a gastrointestinal illness occur at the time of or shortly before soup preparation. This investigation suggests that eating contaminated moose soup at a community gathering led to an outbreak of shigellosis and highlights the risk of eating improperly prepared or stored foods at public gatherings. PMID:8048226

  4. Solvepol: A Reduction Pipeline for Imaging Polarimetry Data

    NASA Astrophysics Data System (ADS)

    Ramírez, Edgar A.; Magalhães, Antônio M.; Davidson, James W., Jr.; Pereyra, Antonio; Rubinho, Marcelo

    2017-05-01

    We present a newly, fully automated, data pipeline, Solvepol, designed to reduce and analyze polarimetric data. It has been optimized for imaging data from the Instituto de Astronomía, Geofísica e Ciências Atmosféricas (IAG) of the University of São Paulo (USP), calcite Savart prism plate-based IAGPOL polarimeter. Solvepol is also the basis of a reduction pipeline for the wide-field optical polarimeter that will execute SOUTH POL, a survey of the polarized southern sky. Solvepol was written using the Interactive data language (IDL) and is based on the Image Reduction and Analysis Facility (IRAF) task PCCDPACK, developed by our polarimetry group. We present and discuss reduced data from standard stars and other fields and compare these results with those obtained in the IRAF environment. Our analysis shows that Solvepol, in addition to being a fully automated pipeline, produces results consistent with those reduced by PCCDPACK and reported in the literature.

  5. In the Soup: An Integrative Unit. Part 1.

    ERIC Educational Resources Information Center

    Atwood, Virginia A.; And Others

    1989-01-01

    Maintains that young children view the world holistically, and thus the social studies curriculum should emphasize the concept of integration. Provides two sample lessons on soup in which students explore geographic concepts, history, economics, and the sociology of soup consumption and production. Includes teaching strategies and learning goals.…

  6. Airborne Polarimeter Intercomparison for the NASA Aerosols-Clouds-Ecosystems (ACE) Mission

    NASA Technical Reports Server (NTRS)

    Knobelspiesse, Kirk; Redemann, Jens

    2014-01-01

    The Aerosols-Clouds-Ecosystems (ACE) mission, recommended by the National Research Council's Decadal Survey, calls for a multi-angle, multi-spectral polarimeter devoted to observations of atmospheric aerosols and clouds. In preparation for ACE, NASA funds the deployment of airborne polarimeters, including the Airborne Multi-angle SpectroPolarimeter Imager (AirMSPI), the Passive Aerosol and Cloud Suite (PACS) and the Research Scanning Polarimeter (RSP). These instruments have been operated together on NASA's ER-2 high altitude aircraft as part of field campaigns such as the POlarimeter DEfinition EXperiment (PODEX) (California, early 2013) and Studies of Emissions and Atmospheric Composition, Clouds and Climate Coupling by Regional Surveys (SEAC4RS, California and Texas, summer 2013). Our role in these efforts has been to serve as an assessment team performing level 1 (calibrated radiance, polarization) and level 2 (retrieved geophysical parameter) instrument intercomparisons, and to promote unified and generalized calibration, uncertainty assessment and retrieval techniques. We will present our progress in this endeavor thus far and describe upcoming research in 2015.

  7. Progress in Airborne Polarimeter Inter Comparison for the NASA Aerosols-Clouds-Ecosystems (ACE) Mission

    NASA Technical Reports Server (NTRS)

    Knobelspiesse, Kirk; Redemann, Jens

    2014-01-01

    The Aerosols-Clouds-Ecosystems (ACE) mission, recommended by the National Research Council's Decadal Survey, calls for a multi-angle, multi-spectral polarimeter devoted to observations of atmospheric aerosols and clouds. In preparation for ACE, NASA funds the deployment of airborne polarimeters, including the Airborne Multiangle SpectroPolarimeter Imager (AirMSPI), the Passive Aerosol and Cloud Suite (PACS) and the Research Scanning Polarimeter (RSP). These instruments have been operated together on NASA's ER-2 high altitude aircraft as part of field campaigns such as the POlarimeter DEfinition EXperiment (PODEX) (California, early 2013) and Studies of Emissions and Atmospheric Composition, Clouds and Climate Coupling by Regional Surveys (SEAC4RS, California and Texas, summer 2013). Our role in these efforts has been to serve as an assessment team performing level 1 (calibrated radiance, polarization) and level 2 (retrieved geophysical parameter) instrument intercomparisons, and to promote unified and generalized calibration, uncertainty assessment and retrieval techniques. We will present our progress in this endeavor thus far and describe upcoming research in 2015.

  8. Intrinsic coincident full-Stokes polarimeter using stacked organic photovoltaics.

    PubMed

    Yang, Ruonan; Sen, Pratik; O'Connor, B T; Kudenov, M W

    2017-02-20

    An intrinsic coincident full-Stokes polarimeter is demonstrated by using strain-aligned polymer-based organic photovoltaics (OPVs) that can preferentially absorb certain polarized states of incident light. The photovoltaic-based polarimeter is capable of measuring four Stokes parameters by cascading four semitransparent OPVs in series along the same optical axis. This in-line polarimeter concept potentially ensures high temporal and spatial resolution with higher radiometric efficiency as compared to the existing polarimeter architecture. Two wave plates were incorporated into the system to modulate the S3 Stokes parameter so as to reduce the condition number of the measurement matrix and maximize the measured signal-to-noise ratio. Radiometric calibration was carried out to determine the measurement matrix. The polarimeter presented in this paper demonstrated an average RMS error of 0.84% for reconstructed Stokes vectors after normalized to S0. A theoretical analysis of the minimum condition number of the four-cell OPV design showed that for individually optimized OPV cells, a condition number of 2.4 is possible.

  9. Lifetime Estimation of a Time Projection Chamber X-ray Polarimeter

    NASA Technical Reports Server (NTRS)

    Hill, Joanne E.; Black, J. Kevin; Brieda, Lubos; Dickens, Patsy L.; deGarcia, Kristina Montt; Hawk, Douglas L.; Hayato, Asami; Jahoda, Keith; Mohammed, Jelila

    2013-01-01

    The Gravity and Extreme Magnetism Small Explorer (GEMS) X-ray polarimeter Instrument (XPI) was designed to measure the polarization of 23 sources over the course of its 9 month mission. The XPI design consists of two telescopes each with a polarimeter assembly at the focus of a grazing incidence mirror. To make sensitive polarization measurements the GEMS Polarimeter Assembly (PA) employed a gas detection system based on a Time Projection Chamber (TPC) technique. Gas detectors are inherently at risk of degraded performance arising from contamination from outgassing of internal detector components or due to loss of gas. This paper describes the design and the materials used to build a prototype of the flight polarimeter with the required GEMS lifetime. We report the results from outgassing measurements of the polarimeter subassemblies and assemblies, enclosure seal tests, life tests, and performance tests that demonstrate that the GEMS lifetime is achievable. Finally we report performance measurements and the lifetime enhancement from the use of a getter.

  10. In the Soup: Integrating and Correlating Social Studies with Other Curriculum Areas: Part Two.

    ERIC Educational Resources Information Center

    Atwood, Virginia A.; And Others

    1989-01-01

    Demonstrates a thematic approach, using soup as the theme, to integrate and correlate elementary social studies with other subject areas. Outlines four soup activities, presenting goals, materials, strategies, and extensions of each. Stresses how integrated curricula effectively develops skills such as observing, inferring, serial ordering, and…

  11. Exploring Weighty Matters with "Cucumber Soup": An Interdisciplinary Approach

    ERIC Educational Resources Information Center

    Columba, Lynn

    2007-01-01

    Children's literature can play a significant role in integrating math and science concepts into real-world applications. One particularly delightful selection is "Cucumber Soup" (Krudwig, 1998). This book can create a context--making cucumber soup--for weighing and for a real-life on adding fractions. This kind of learning context takes children…

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yokosawa, A.

    The production of polarized antiproton beams at Fermilab is briefly reviewed. Two types of high-energy anti p polarimeters are described - the Coulomb-nuclear polarimeter and the Primakoff-effect polarimeter. The production of 8.9 GeV/c polarized antiprotons before entering the Fermilab accumulator ring is then discussed. 5 refs., 6 figs. (LEW)

  13. What is the Universe made of?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paris, Mark

    A team of physicists and astrophysicists at Los Alamos National Laboratory, in collaboration with leading universities around the country, are using the Laboratory’s supercomputers to simulate the Big Bang nucleosynthesis and the early universe to unprecedented precision. These researchers developed a code, called BURST that describes the universe from a time of a few seconds after the Big Bang to several hundred thousand years later. BURST allows physicists to study the microscopic, quantum nature of fundamental particles — like nuclei and the ghostly, weakly interacting neutrinos — by simulating the universe at its largest, cosmological scale. BURST simultaneously describes allmore » the particles present in the early universe as they develop, tracking their evolution, particularly the amounts of light nuclei fused in the cosmic soup.« less

  14. Primordial Evolution in the Finitary Process Soup

    NASA Astrophysics Data System (ADS)

    Görnerup, Olof; Crutchfield, James P.

    A general and basic model of primordial evolution—a soup of reacting finitary and discrete processes—is employed to identify and analyze fundamental mechanisms that generate and maintain complex structures in prebiotic systems. The processes—ɛ-machines as defined in computational mechanics—and their interaction networks both provide well defined notions of structure. This enables us to quantitatively demonstrate hierarchical self-organization in the soup in terms of complexity. We found that replicating processes evolve the strategy of successively building higher levels of organization by autocatalysis. Moreover, this is facilitated by local components that have low structural complexity, but high generality. In effect, the finitary process soup spontaneously evolves a selection pressure that favors such components. In light of the finitary process soup's generality, these results suggest a fundamental law of hierarchical systems: global complexity requires local simplicity.

  15. Nutrition for homeless populations: shelters and soup kitchens as opportunities for intervention.

    PubMed

    Koh, Katherine A; Bharel, Monica; Henderson, David C

    2016-05-01

    Nutrition is a daily challenge for the homeless population in America. Homeless individuals suffer from a high prevalence of diseases related to poor diet, yet there has been little public health effort to improve nutrition in this population. Shelters and soup kitchens may have an untapped potential to impact food access, choice and quality. We offer ideas for intervention and lessons learned from ten shelters and soup kitchens around Greater Boston, MA, USA. By advancing food quality, education and policies in shelters and soup kitchens, the homeless population can be given an opportunity to restore its nutrition and health.

  16. A Shoebox Polarimeter: An Inexpensive Analytical Tool for Teachers and Students

    ERIC Educational Resources Information Center

    Mehta, Akash; Greenbowe, Thomas J.

    2011-01-01

    A polarimeter can determine the optical activity of an organic or inorganic compound by providing information about the optical rotation of plane-polarized light when transmitted through that compound. This "Journal" has reported various construction methods for polarimeters. We report a unique construction using a shoebox, recycled office…

  17. Birefringence Polarimeter Using Dual LiNbO3 Electrooptic Crystal Modulators

    NASA Astrophysics Data System (ADS)

    Saitou, Takeshi; Nurdin Bin, Muhammad; Kowa, Hiroyuki; Umeda, Norihiro; Takizawa, Kuniharu; Kondoh, Eiichi; Jin, Lianhua

    2012-08-01

    A birefringence polarimeter that uses dual LiNbO3 electrooptic crystal modulators operating at a frequency ratio of 4:1 is described. The significance of this polarimeter is that the birefringent parameters of a sample are obtained only from the modulated polarization status. The measurement, therefore, avoids depolarization effects resulting from the sample itself and the rest of the optical system. The high speed and accuracy of this polarimeter are shown by measurements using a quarter-wave plate, a Babinet-Soleil compensator, and a phase modulator.

  18. A low-cost polarimeter for an undergraduate laboratory to study the polarization pattern of skylight

    NASA Astrophysics Data System (ADS)

    Abayaratne, Chula P.; Bandara, Vibodha

    2017-03-01

    A simple, low-cost, fully automated polarimeter, which demonstrates fundamental properties of skylight scattering and polarization for undergraduate physics students, is described. The polarimeter includes a microprocessor-based control unit, a Sun tracker, an elevation-azimuth mount with two degrees of freedom, and a polarization sensor unit equipped with a light-dependent resistor for measuring light intensity. Results obtained in the principal plane of the Sun using the polarimeter on a relatively clear day, together with the theoretically expected results for a molecular atmosphere, are presented. A root-mean-square error comparison indicates fairly good agreement between theory and experiment. Construction and experimentation with the polarimeter will provide students with insight into important physical concepts involved in skylight scattering and polarization as well as improve their instrumentation capabilities.

  19. Development of the GEM-TPC X-ray Polarimeter with the Scalable Readout System

    NASA Astrophysics Data System (ADS)

    Kitaguchi, Takao; Hayato, Asami; Iwakiri, Wataru; Takeuchi, Yoko; Kubota, Megu; Nishida, Kazuki; Enoto, Teruaki; Tamagawa, Toru

    2018-02-01

    We have developed a gaseous Time Projection Chamber (TPC) containing a single-layered foil of a gas electron multiplier (GEM) to open up a new window on cosmic X-ray polarimetry in the 2-10 keV band. The micro-pattern TPC polarimeter in combination with the Scalable Readout System produced by the RD51 collaboration has been built as an engineering model to optimize detector parameters and improve polarimeter sensitivity. The polarimeter was characterized with unpolarized X-rays from an X-ray generator in a laboratory and polarized X-rays on the BL32B2 beamline at the SPring-8 synchrotron radiation facility. Preliminary results show that the polarimeter has a comparable modulation factor to a prototype of the flight one.

  20. Writing and Retelling Multiple Ethnographic Tales of a Soup Kitchen for the Homeless.

    ERIC Educational Resources Information Center

    Miller, Dana L.; Creswell, John W.; Olander, Lisa

    An ethnographic study narrated three tales about a soup kitchen for the homeless and the near-homeless. To provide a cultural, ethnographic analysis, and share fieldwork experiences the study began with realist and confessional tales. These two tales emerged from the initial writing and presenting of the soup kitchen ethnography to qualitative…

  1. Acute fluid ingestion in the treatment of orthostatic intolerance - important implications for daily practice.

    PubMed

    Z'Graggen, W J; Hess, C W; Humm, A M

    2010-11-01

    Rapid water ingestion improves orthostatic intolerance (OI) in multiple system atrophy (MSA) and postural tachycardia syndrome (PoTS). We compared haemodynamic changes after water and clear soup intake, the latter being a common treatment strategy for OI in daily practice. Seven MSA and seven PoTS patients underwent head-up tilt (HUT) without fluid intake and 30 min after drinking 450 ml of water and clear soup, respectively. All patients suffered from moderate to severe OI because of neurogenic orthostatic hypotension (OH) and excessive orthostatic heart rate (HR) increase, respectively. Beat-to-beat cardiovascular indices were measured non-invasively. In MSA, HUT had to be terminated prematurely in 2/7 patients after water, but in 6/7 after clear soup. At 3 min of HUT, there was an increase in blood pressure of 15.7(8.2)/8.3(2.3) mmHg after water, but a decrease of 11.6(18.9)/8.1(9.2) mmHg after clear soup (P < 0.05). In PoTS, HUT could always be completed for 10 min, but OI subjectively improved after both water and clear soup. The attenuation of excessive orthostatic HR increase did not differ significantly after water and clear soup drinking. In MSA, clear soup cannot substitute water for eliciting a pressor effect, but even worsens OI after rapid ingestion. In PoTS, acute water and clear soup intake both result in improvement of OI. These findings cannot solely be explained by difference in osmolarity but may reflect some degree of superimposed postprandial hypotension in widespread autonomic failure in MSA compared to the mild and limited autonomic dysfunction in PoTS. © 2010 The Author(s). Journal compilation © 2010 EFNS.

  2. Supradural inflammatory soup in awake and freely moving rats induces facial allodynia that is blocked by putative immune modulators.

    PubMed

    Wieseler, Julie; Ellis, Amanda; McFadden, Andrew; Stone, Kendra; Brown, Kimberley; Cady, Sara; Bastos, Leandro F; Sprunger, David; Rezvani, Niloofar; Johnson, Kirk; Rice, Kenner C; Maier, Steven F; Watkins, Linda R

    2017-06-01

    Facial allodynia is a migraine symptom that is generally considered to represent a pivotal point in migraine progression. Treatment before development of facial allodynia tends to be more successful than treatment afterwards. As such, understanding the underlying mechanisms of facial allodynia may lead to a better understanding of the mechanisms underlying migraine. Migraine facial allodynia is modeled by applying inflammatory soup (histamine, bradykinin, serotonin, prostaglandin E2) over the dura. Whether glial and/or immune activation contributes to such pain is unknown. Here we tested if trigeminal nucleus caudalis (Sp5C) glial and/or immune cells are activated following supradural inflammatory soup, and if putative glial/immune inhibitors suppress the consequent facial allodynia. Inflammatory soup was administered via bilateral indwelling supradural catheters in freely moving rats, inducing robust and reliable facial allodynia. Gene expression for microglial/macrophage activation markers, interleukin-1β, and tumor necrosis factor-α increased following inflammatory soup along with robust expression of facial allodynia. This provided the basis for pursuing studies of the behavioral effects of 3 diverse immunomodulatory drugs on facial allodynia. Pretreatment with either of two compounds broadly used as putative glial/immune inhibitors (minocycline, ibudilast) prevented the development of facial allodynia, as did treatment after supradural inflammatory soup but prior to the expression of facial allodynia. Lastly, the toll-like receptor 4 (TLR4) antagonist (+)-naltrexone likewise blocked development of facial allodynia after supradural inflammatory soup. Taken together, these exploratory data support that activated glia and/or immune cells may drive the development of facial allodynia in response to supradural inflammatory soup in unanesthetized male rats. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Effect of incorporation of soy flour on functional, nutritional, and sensory properties of mushroom-moringa-supplemented healthy soup.

    PubMed

    Mohajan, Suman; Orchy, Tania N; Farzana, Tasnim

    2018-05-01

    The research study was conducted to evaluate the effect of soy flour on functional, nutritional, and sensory properties of mushroom-moringa-supplemented soup which could be used as a protein-supplemented ready-to-eat food. In this study, corn flour was supplemented with soy flour at different levels such as 20% (T4), 15% (T3), 10% (T2), and 5% (T1), and without soy flour was kept as control (T0). Fixed amount of mushroom and moringa leaf powder was added in all soup powders. Soup powders were analyzed for functional, nutritional, and sensory parameters. Bulk density (0.82-0.74 g/ml), dispersibility (82.1%-75.9%), pH (6.17-6.13), swelling capacity (3.98-3.65 ml/g), and viscosity were decreased, while water absorption capacity (70%-94%) was increased with increasing of soy flour percentages. Protein content of all the treatment groups increased from 10.66% to 19.97% along with a significant increased in fat (1.43%-6.97%), fiber (1.10%-2.30%), ash (15.77%-16.40%), and energy value (328.38-353.21 kcal/100 g) while decreased in moisture and carbohydrate content. On sensory evaluation, soup powders with 10% (T2) level of soy flour incorporation had highest scores for all the sensory attributes evaluated. Based on these results, it can be concluded that soy flour has effect on functional, nutritional, and sensory properties of soup powders and 10% supplementation of soy flour is suitable for ready-to-eat soup formulation. Besides these, use of mushroom and moringa leaf may also increase its nutritional value. Soup developed in this way may be sufficient to meet day-to-day nutritional requirements as a supplement.

  4. Methylmercury in dried shark fins and shark fin soup from American restaurants.

    PubMed

    Nalluri, Deepthi; Baumann, Zofia; Abercrombie, Debra L; Chapman, Demian D; Hammerschmidt, Chad R; Fisher, Nicholas S

    2014-10-15

    Consumption of meat from large predatory sharks exposes human consumers to high levels of toxic monomethylmercury (MMHg). There also have been claims that shark fins, and hence the Asian delicacy shark fin soup, contain harmful levels of neurotoxic chemicals in combination with MMHg, although concentrations of MMHg in shark fins are unknown. We measured MMHg in dried, unprocessed fins (n=50) of 13 shark species that occur in the international trade of dried shark fins as well as 50 samples of shark fin soup prepared by restaurants from around the United States. Concentrations of MMHg in fins ranged from 9 to 1720 ng/g dry wt. MMHg in shark fin soup ranged from <0.01 to 34 ng/mL, with MMHg averaging 62 ± 7% of total Hg. The highest concentrations of MMHg and total Hg were observed in both fins and soup from large, high trophic level sharks such as hammerheads (Sphyrna spp.). Consumption of a 240 mL bowl of shark fin soup containing the average concentration of MMHg (4.6 ng/mL) would result in a dose of 1.1 μg MMHg, which is 16% of the U.S. EPA's reference dose (0.1 μg MMHg per 1 kg per day in adults) of 7.4 μg per day for a 74 kg person. If consumed, the soup containing the highest measured MMHg concentration would exceed the reference dose by 17%. While shark fin soup represents a potentially important source of MMHg to human consumers, other seafood products, particularly the flesh of apex marine predators, contain much higher MMHg concentrations and can result in substantially greater exposures of this contaminant for people. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Development of real-time rotating waveplate Stokes polarimeter using multi-order retardation for ITER poloidal polarimeter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Imazawa, R., E-mail: imazawa.ryota@jaea.go.jp; Kawano, Y.; Ono, T.

    The rotating waveplate Stokes polarimeter was developed for ITER (International Thermonuclear Experimental Reactor) poloidal polarimeter. The generalized model of the rotating waveplate Stokes polarimeter and the algorithm suitable for real-time field-programmable gate array (FPGA) processing were proposed. Since the generalized model takes into account each component associated with the rotation of the waveplate, the Stokes parameters can be accurately measured even in unideal condition such as non-uniformity of the waveplate retardation. Experiments using a He-Ne laser showed that the maximum error and the precision of the Stokes parameter were 3.5% and 1.2%, respectively. The rotation speed of waveplate was 20 000more » rpm and time resolution of measuring the Stokes parameter was 3.3 ms. Software emulation showed that the real-time measurement of the Stokes parameter with time resolution of less than 10 ms is possible by using several FPGA boards. Evaluation of measurement capability using a far-infrared laser which ITER poloidal polarimeter will use concluded that measurement error will be reduced by a factor of nine.« less

  6. Development of real-time rotating waveplate Stokes polarimeter using multi-order retardation for ITER poloidal polarimeter.

    PubMed

    Imazawa, R; Kawano, Y; Ono, T; Itami, K

    2016-01-01

    The rotating waveplate Stokes polarimeter was developed for ITER (International Thermonuclear Experimental Reactor) poloidal polarimeter. The generalized model of the rotating waveplate Stokes polarimeter and the algorithm suitable for real-time field-programmable gate array (FPGA) processing were proposed. Since the generalized model takes into account each component associated with the rotation of the waveplate, the Stokes parameters can be accurately measured even in unideal condition such as non-uniformity of the waveplate retardation. Experiments using a He-Ne laser showed that the maximum error and the precision of the Stokes parameter were 3.5% and 1.2%, respectively. The rotation speed of waveplate was 20 000 rpm and time resolution of measuring the Stokes parameter was 3.3 ms. Software emulation showed that the real-time measurement of the Stokes parameter with time resolution of less than 10 ms is possible by using several FPGA boards. Evaluation of measurement capability using a far-infrared laser which ITER poloidal polarimeter will use concluded that measurement error will be reduced by a factor of nine.

  7. A Combined Retrieval of Aerosol Microphysical Properties using active HSRL and Passive Polarimeter Multi-sensor Data

    NASA Astrophysics Data System (ADS)

    Liu, X.; Stamnes, S.; Ferrare, R. A.; Hostetler, C. A.; Burton, A. S.; Chemyakin, E.; Sawamura, P.; Mueller, D.

    2017-12-01

    Vertically resolved measurements of aerosol optical, microphysical, and macrophysical parameters are required to better understand the influence of aerosols on climate and air quality. We will describe an Optimal Estimation (OE) retrieval framework which can perform aerosol property retrievals in three modes: 1) lidar-only, 2) polarimeter-only, and 3) combined lidar-polarimeter muti-sensor system. The lidar data can be profile measurements by any high spectral resolution lidar (HSRL) and/or Raman lidar with multiple wavelengths of aerosol backscattering (β) and extinction (α). The polarimeter data can be any multi-angle and multi-wavelength measurements with 2 or 3 polarization components. We will show aerosol microphysical retrieval results from the HSRL-2 data measured from various NASA airborne field campaigns including the recent ORACLES mission. We will also show the OE retrieval results from the polarimeter-only mode. Finally, we will demonstrate how the information content of the aerosol microphysical retrieval is increased by combining the active HSRL and passive polarimeter data in our simultaneous OE retrieval system.

  8. No effect on intake and liking of soup enhanced with mono-sodium glutamate and celery powder among elderly people with olfactory and/or gustatory loss.

    PubMed

    Essed, Natasja H; Kleikers, Suzanne; van Staveren, Wija A; Kok, Frans J; de Graaf, Cees

    2009-01-01

    Mono-sodium glutamate (MSG) and/or flavors may improve palatability and intake in elderly people. Whether this improvement is related to a decline in chemosensory sensitivity is unclear. We examined the effect of flavor-enhanced tomato soup (1,200 mg/l MSG (0.12% MSG) + 3 g/l celery powder) versus non-enhanced soup on intake and liking in 120 older adults (72+/-6 years). Olfactory and gustatory performance was measured. For the whole group, no difference in intake (198 g vs. 203 g) (P =0.97), liking (6.6 vs. 6.7) (P =0.99) and strength (7.2 vs. 7.2) (P =0.76) between the soups was found. Intake (P =0.52), liking (P =0.90) and strength (P =1.00) between the soups were not different within the low olfactory/low gustatory group. Intake and liking of the flavor-enhanced soup was not increased within elderly with low chemosensory sensitivity. Enhancing flavors to increase intake and liking may not be a uniform approach due to the heterogeneity in chemosensory losses among elderly people.

  9. Cotton-Mouton polarimeter with HCN laser on CHS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Akiyama, T.; Kawahata, K.; Ito, Y.

    Polarimeters based on the Cotton-Mouton effect hold promise for electron density measurements. We have designed and installed a Cotton-Mouton polarimeter on the Compact Helical System. The Cotton-Mouton effect is measured as the phase difference between probe and reference beams. In this system, an interferometric measurement can be performed simultaneously with the same probe chord. The light source is a HCN laser (wavelength of 337 {mu}m). Digital complex demodulation is adopted for small phase analysis. The line averaged density evaluated from the polarimeter along a plasma center chord is almost consistent with that from the interferometer.

  10. Characterization of Detectors and Instrument Systematics for the SPIDER CMB Polarimeter

    NASA Astrophysics Data System (ADS)

    Tucker, Rebecca Suzanne

    We know from the CMB and observations of large-scale structure that the universe is extremely flat, homogenous, and isotropic. The current favored mechanism for generating these characteristics is inflation, a theorized period of exponential expansion of the universe that occurred shortly after the Big Bang. Most theories of inflation generically predict a background of stochastic gravitational waves. These gravitational waves should leave their unique imprint on the polarization of the CMB via Thompson scattering. Scalar perturbations of the metric will cause a pattern of polarization with no curl (E-mode). Tensor perturbations (gravitational waves) will cause a unique pattern of polarization on the CMB that includes a curl component (B-mode). A measurement of the ratio of the tensor to scalar perturbations (r ) tells us the energy scale of inflation. Recent measurements by the BICEP2 team detect the B-mode spectrum with a tensor-to-scalar ratio of r=0.2 (+0.05, -0.07). An independent confirmation of this result is the next step towards understanding the inflationary universe. This thesis describes my work on a balloon-borne polarimeter called SPIDER, which is designed to illuminate the physics of the early universe through measurements of the cosmic microwave background polarization. SPIDER consists of six single-frequency, on-axis refracting telescopes contained in a shared-vacuum liquid-helium cryostat. Its large format arrays of millimeter-wave detectors and tight control of systematics will give it unprecedented sensitivity. This thesis describes how the SPIDER detectors are characterized and calibrated for flight, as well as how the systematics requirements for the SPIDER system are simulated and measured.

  11. Evaluation of rheological, bioactives and baking characteristics of mango ginger (curcuma amada) enriched soup sticks.

    PubMed

    Crassina, K; Sudha, M L

    2015-09-01

    Wheat flour was replaced with mango ginger powder (MGP) at 0, 5, 10 and 15 %. Influence of MGP on rheological and baking characteristics was studied. Farinograph was used to study the mixing profile of wheat flour-MGP blend. Pasting profile of the blends namely gelatinization and retrogradation were carried out using micro-visco-amylograph. Test baking was done to obtain the optimum level of replacement and processing conditions. Sensory attributes consisting texture, taste, overall quality and breaking strength were assessed. Nutritional characterization of the soup sticks in terms of protein and starch in vitro digestibility, dietary fiber, minerals, polyphenols and antioxidant activity were determined using standard methods. With the increasing levels of MGP from 0 to 15 %, the farinograph water absorption increased from 60 to 66.7 %. A marginal increase in the gelatinization temperature from 65.4 to 66.2 °C was observed. Retrogradation of gelatinized starch granules decreased with the addition of MGP. The results indicated that the soup stick with 10 % MG had acceptable sensory attributes. The soup stick showed further improvement in terms of texture and breaking strength with the addition of gluten powder, potassium bromate and glycerol monostearate. The total dietary fiber and antioxidant activity of the soup sticks having 10 % MGP increased from 3.31 to 8.64 % and 26.83 to 48.06 % respectively as compared to the control soup sticks. MGP in soup sticks improved the nutritional profile.

  12. A New Cost-Effective Diode Laser Polarimeter Apparatus Constructed by Undergraduate Students

    ERIC Educational Resources Information Center

    Lisboa, Pedro; Sotomayor, Joo; Ribeiro, Paulo

    2010-01-01

    The construction of a diode laser polarimeter apparatus by undergraduate students is described. The construction of the modular apparatus by undergraduate students gives them an insight into how it works and how the measurement of a physical or chemical property is conducted. The students use the polarimeter to obtain rotation angle values for the…

  13. Polarized-pixel performance model for DoFP polarimeter

    NASA Astrophysics Data System (ADS)

    Feng, Bin; Shi, Zelin; Liu, Haizheng; Liu, Li; Zhao, Yaohong; Zhang, Junchao

    2018-06-01

    A division of a focal plane (DoFP) polarimeter is manufactured by placing a micropolarizer array directly onto the focal plane array (FPA) of a detector. Each element of the DoFP polarimeter is a polarized pixel. This paper proposes a performance model for a polarized pixel. The proposed model characterizes the optical and electronic performance of a polarized pixel by three parameters. They are respectively major polarization responsivity, minor polarization responsivity and polarization orientation. Each parameter corresponds to an intuitive physical feature of a polarized pixel. This paper further extends this model to calibrate polarization images from a DoFP (division of focal plane) polarimeter. This calibration work is evaluated quantitatively by a developed DoFP polarimeter under varying illumination intensity and angle of linear polarization. The experiment proves that our model reduces nonuniformity to 6.79% of uncalibrated DoLP (degree of linear polarization) images, and significantly improves the visual effect of DoLP images.

  14. Armed Forces Food Preferences

    DTIC Science & Technology

    1974-12-01

    Breakfast Cereals 11 Griddle Cakes 12 Eggs 13 Breakfast Meats Arm®d Forces High Preference and Low Preference Foods HIGH Tom. Veg. Noodle Soup...Tomato Soup Chicken Noodle Soup Orange Juice Grape Juice Lemonade Iced Tea Milk Ice Cream Cola Doughnuts Sweet Rolls Cold Cereal Griddle...Grape Lemonade Lime-Flavored Drink Cherry-Flavored Drink Instant Coffee Freeze-Dried Coffee Skimmed Milk Buttermilk Frutt-Flvd. Yogurt Lo-cal

  15. 40 CFR 407.82 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... limitations for the soups subcategory are based upon pounds (lb) or kilograms (kg) of pollutant per 1000... 0.24 0.17 Soups 4.14 2.46 1.69 Tomato-starch-cheese canned specialties 1.87 1.08 0.72 (b) The... only the annual average TSS limitations. Effluent limitations for the soups subcategory are based upon...

  16. On testing of the photometer-polarimeter UVP layout using a telescope on Earth's surface

    NASA Astrophysics Data System (ADS)

    Nevodovskyi, P. V.; Vidmachenko, A. P.; Morozhenko, O. V.; Zbrutskyi, O.; Ivakhiv, O. V.

    2016-08-01

    One of the causes of climate change (changing of concentration of stratospheric ozone) - is variations due to aerosol optical thickness in the upper layers of Earth's atmosphere. To solve the problem is necessary to make a space experiment to receive polarization observational data. Their analysis will: determine the value of the real part of the refractive index, the size of the stratospheric aerosol, optical thickness of the stratospheric aerosol layer, investigate aerosol's layer horizontal structure and its changes over time. Main Astronomical Observatory of NAS of Ukraine jointly with the National Technical University of Ukraine "KPI" and National University "Lviv Polytechnic" for a long time working on the design of polarimeter to study the stratospheric layer of the Earth from board of artificial satellites. During this time accumulated a great experience in such work, and created a layout of compact board ultraviolet polarimeter UFP [1-4]. For testing of ground variant of layout of UFP, it is installed on the telescope AZT-2 of the Main Astronomical Observatory NAS of Ukraine (Kyiv). Using it we plan to investigate the possibility of determining the degree of polarization of the twilight glow of Earth's atmosphere, and implementation of this technique in the development of space experiment on investigation of the stratospheric aerosol from space. For this purpose we develop a special set of equipment that will adapt the layout for working of UFP with telescope AZT-2, and carry out the above mentioned work (see. in [5-7]). References. 1. P. Nevodovskyi, O. Morozhenko, A. Vidmachenko, O. Ivakhiv, M. Geraimchuk, O. Zbrutskyi. Tiny Ultraviolet Polarimeter for Earth Stratosphere from Space Investigation // Proceedings of 8th IEEE International Conference on Intelligent Data Acquisition and Advanced Computing Systems: Technology and Applications (IDAACS'2015). 24-26 September 2015, Proceedings. Warsaw, Poland. Vol.81, p. 28-32. 2. Nevodovsksiy P. V., Morozhenko A. V. Studies of stratospheric ozone layer from near-earth orbit utilizing ultraviolet polarimeter // Acta Astronautica. 2009, vol. 64, no 1, p. 54-58. 3. Nevodovskij P. V. Kvantakons and optimization of their parameters for astronomical observations Kinematika i Fizika Nebesnykh Tel. 2001, vol. 17, no. 3, p. 279-288. 4. A. P. Vid'machenko, P. V. Nevodovsky. A cooled photomultiplier with an InGaAs photocathode developed for the spectropolarimetry observations // Kinematika i Fizika Nebesnykh Tel. 2000. Suppl. 3, p. 283-285. 5. Morozhenko A. V., Vidmachenko A. P., Nevodovskiy P. V., Kostogryz N. M. On the efficiency of polarization measurements while studying aerosols in the terrestrial atmosphere // Kinematics and Physics of Celestial Bodies. 2014, vol. 30, no. 1, p. 11-21. 6. A.V. Morozhenko, A.P. Vidmachenko, P.V. Nevodovskyi. Aerosol in the upper layer of earth's atmosphere // Kinematics and Physics of Celestial Bodies. 2013, vol. 29, no. 5, p. 243-246. 7. Morozhenko A.V. Polarimetry of twilight sky and stratospheric aerosol // Kinematics and Physics of Celestial Bodies. 2010, vol. 26, no. 1, p. 36-38.

  17. REDSoX: Monte-Carlo ray-tracing for a soft x-ray spectroscopy polarimeter

    NASA Astrophysics Data System (ADS)

    Günther, Hans M.; Egan, Mark; Heilmann, Ralf K.; Heine, Sarah N. T.; Hellickson, Tim; Frost, Jason; Marshall, Herman L.; Schulz, Norbert S.; Theriault-Shay, Adam

    2017-08-01

    X-ray polarimetry offers a new window into the high-energy universe, yet there has been no instrument so far that could measure the polarization of soft X-rays (about 17-80 Å) from astrophysical sources. The Rocket Experiment Demonstration of a Soft X-ray Polarimeter (REDSoX Polarimeter) is a proposed sounding rocket experiment that uses a focusing optic and splits the beam into three channels. Each channel has a set of criticalangle transmission (CAT) gratings that disperse the x-rays onto a laterally graded multilayer (LGML) mirror, which preferentially reflects photons with a specific polarization angle. The three channels are oriented at 120 deg to each other and thus measure the three Stokes parameters: I, Q, and U. The period of the LGML changes with position. The main design challenge is to arrange the gratings so that they disperse the spectrum in such a way that all rays are dispersed onto the position on the multi-layer mirror where they satisfy the local Bragg condition despite arriving on the mirror at different angles due to the converging beam from the focusing optics. We present a polarimeteric Monte-Carlo ray-trace of this design to assess non-ideal effects from e.g. mirror scattering or the finite size of the grating facets. With mirror properties both simulated and measured in the lab for LGML mirrors of 80-200 layers we show that the reflectivity and the width of the Bragg-peak are sufficient to make this design work when non-ideal effects are included in the simulation. Our simulations give us an effective area curve, the modulation factor and the figure of merit for the REDSoX polarimeter. As an example, we simulate an observation of Mk 421 and show that we could easily detect a 20% linear polarization.

  18. Characterizing and Modeling the Noise and Complex Impedance of Feedhorn-Coupled TES Polarimeters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Appel, J. W.; Beall, J. A.; Essinger-Hileman, T.

    2009-12-16

    We present results from modeling the electrothermal performance of feedhorn-coupled transition edge sensor (TES) polarimeters under development for use in cosmic microwave background (CMB) polarization experiments. Each polarimeter couples radiation from a corrugated feedhorn through a planar orthomode transducer, which transmits power from orthogonal polarization modes to two TES bolometers. We model our TES with two- and three-block thermal architectures. We fit the complex impedance data at multiple points in the TES transition. From the fits, we predict the noise spectra. We present comparisons of these predictions to the data for two TESes on a prototype polarimeter.

  19. [Textual criticism and discrimination on the naming of"Five-abstention Soup of Medical Professional"from the Han-tomb of the Marquis of Haihun].

    PubMed

    Wang, Y R; Yuan, Y; Xu, C Q; Cao, L J; Wang, Y L; Huang, L Q

    2017-05-28

    A lacquer vessel with the inscription of Yi gong wu jin tang (Five-abstention Soup of Medical Profession) has been unearthed from the Han-tomb of Marquis of Haihun, in which"Five abstentions"is related to the incantations and abstention therapies prevalent in the Qin and Han Dynasties. The"Five-abstention Law"is the five rituals and methods during the process of practicing incantations and abstentions therapies including"keeping one's thinking ( cun si )","holding the breath( bi qi )","twirling eyes ( nian mu )","stepping after Yu's sample ( yu bu )"and"incanting and blessing ( zhou zhu )". The"Five-abstention Law"uses the medium"soup"to achieve the purpose of treatment."Soup"refers either to"decoction"or to"magic water". The lacquer vessel with the inscription"Five-abstention Soup of Medical professional"could be an instrument for implementing the process of practising the"Five-abstention Law", reflecting the historical facts that Liu He, the Marquis Haihun did accept the incantations and abstention therapies.

  20. Salt reduction in vegetable soup does not affect saltiness intensity and liking in the elderly and children.

    PubMed

    Gonçalves, Carla; Monteiro, Sérgio; Padrão, Patrícia; Rocha, Ada; Abreu, Sandra; Pinho, Olívia; Moreira, Pedro

    2014-01-01

    Reduction of added salt levels in soups is recommended. We evaluated the impact of a 30% reduction of usual added salt in vegetable soups on elderly and children's saltiness and liking evaluation. Subjects were elderly and recruited from two public nursing homes (29 older adults, 79.7±8.9 years), and preschool children recruited from a public preschool (49 children, 4.5±1.3 years). This study took place in institutional lunchrooms. Through randomization and crossover, the subjects participated in two sensory evaluation sessions, on consecutive days, to assess perceived saltiness intensity (elderly sample) and liking (elderly and children samples) of a vegetable soup with baseline salt content and with a 30% salt reduction. Elderly rated perceived liking through a 10 cm visual analogue scale ['like extremely' (1) to 'dislike extremely' (10)] and children through a five-point facial scale ['dislike very much' (1) to 'like very much' (5)]. After 30% added salt reduction in vegetable soup, there were no significant differences in saltiness noted by the elderly (p=0.150), and in perceived liking by children (p=0.160) and elderly (p=0.860). A 30% salt reduction in vegetable soup may be achieved without compromising perceived saltiness and liking in children and the elderly.

  1. Effects of frying and boiling on the formation of heterocyclic amines in braised chicken.

    PubMed

    Yao, Y; Peng, Z Q; Shao, B; Wan, K H; Wang, F L; Zhang, Y W; Li, J K; Hui, T

    2013-11-01

    Braised chicken is a traditional ready-to-eat poultry product produced by frying chicken coated with maltose or honey and then boiling it in a soup that is circularly used. This study examined the effects of the frying time, honey concentration, boiling time, and cycle times of the soup on the formation of heterocyclic amines (HA), a class of mutagenic/carcinogenic compounds generated in heated muscle meat. Nine HA in chicken and recycled soups were analyzed by HPLC with UV and fluorescence detection. 1-Methyl-9H-pyrido[3,4-b]indole (Harman), 9H-pyrido[3,4-b]indole (Norharman), and 3-amino-1,4-dimethyl-5H-pyrido[4,3-b]indole (Trp-P-1) were detected in most samples, and the amount of each HA increased with the frying or boiling time. Chicken skin was found to have higher HA content than chicken meat. More HA were detected in the soup than in the chicken, in most cases. 2-Amino-3-methylimidazo[4,5-f]quinoline and 2-amino-3,4,8-trimethylimidazoquinoxaline (4,8-DiMeIQx) were also detected in chicken and soup circularly boiled 20 times, and the total amount of HA reached 68.80 and 96.98 ng/g in chicken and soup, respectively.

  2. Polarised Photon Beams for the BGO-OD Experiment at ELSA

    NASA Astrophysics Data System (ADS)

    Zimmermann, T.; Bella, A.; Alef, S.; Bayadilov, D.; Beck, R.; Becker, M.; Bielefeldt, P.; Boese, S.; Braghieri, A.; Brinkmann, K.; Cole, P.; Curciarello, F.; De Leo, V.; Di Salvo, R.; Dutz, H.; Elsner, D.; Fantini, A.; Freyermuth, O.; Friedrich, S.; Frommberger, F.; Ganenko, V.; Gervino, G.; Ghio, F.; Giardina, G.; Goertz, S.; Gridnev, A.; Gutz, E.; Hammann, D.; Hannappel, J.; Hartmann, P.; Hillert, W.; Ignatov, A.; Jahn, R.; Joosten, R.; Jude, T. C.; Klein, F.; Koop, K.; Krusche, B.; Lapik, A.; Levi Sandri, P.; Lopatin, I. V.; Mandaglio, G.; Messi, F.; Messi, R.; Metag, V.; Moricciani, D.; Mushkarenkov, A.; Nanova, M.; Nedorezov, V.; Novinskiy, D.; Pedroni, P.; Reitz, B.; Romaniuk, M.; Rostomyan, T.; Rudnev, N.; Schaerf, C.; Scheluchin, G.; Schmieden, H.; Stugelev, A.; Sumachev, V.; Tarakanov, V.; Vegna, V.; Walther, D.; Watts, D.; Zaunick, H.

    The new BGO-OD experiment at the electron accelerator ELSA, of the University of Bonn, is designed to study the reaction dynamics of nucleon excitations in meson photoproduction. It consists of a central BGO calorimeter with a magnetic spectrometer in forward direction. The physics programme includes the measurement of polarisation observables using linearly and circularly polarised photon beams. Linear polarisation is obtained by coherent bremsstrahlung off a diamond crystal, and circular polarisation is obtained via bremsstrahlung from longitudinally polarised electrons. The degree of linear polarisation is determined from the bremsstrahlung spectrum itself. To determine the polarisation of the circularly polarised photon beam, the polarisation of the electron beam is measured by a Møller polarimeter. As a preliminary consistency check, the (linear) polarisation observable, Σ, was compared to world data for π0 and η photoproduction. To determine the degree of circular polarisation, a Møller polarimeter was setup and first measurements of the electron beam polarisation performed.

  3. Evaluation of whey, milk, and delactosed permeates as salt substitutes.

    PubMed

    Smith, S T; Metzger, L; Drake, M A

    2016-11-01

    Whey and milk permeates are by-products of high-protein dairy powder manufacture. Previous work has shown that these permeates contribute to salty taste without contributing significantly to sodium content. The objective of this study was to explore the sensory characteristics and compositional analysis of permeates from different milk and whey streams and a low-sodium product application made from them. Skim milk, Cheddar, cottage, and Mozzarella cheese whey permeates were manufactured in triplicate, and delactosed whey permeate was obtained in triplicate. Composition (protein, fat, solids, minerals) was conducted on permeates. Organic acid composition was determined using HPLC. Volatile compounds were extracted from permeates by solid phase microextraction with gas chromatography-mass spectrometry. A trained sensory panel documented sensory attributes of permeates and cream of broccoli soups with and without salt or permeates followed by consumer acceptance testing (n=105) on the soups. Cottage cheese whey permeate contained a higher lactic acid content than other permeates, which has been shown to contribute to a higher salty taste. Cottage cheese whey permeate also contained potato or brothy and caramel flavors and sour and salty tastes, whereas delactosed whey permeate had high intensities of cardboard and beefy or brothy flavors and salty taste. Milk, Cheddar, and Mozzarella cheese whey permeates were characterized by sweet taste and cooked milky flavor. Permeates with higher cardboard flavor had higher levels of aldehydes. All permeates contributed to salty taste and to salty taste perception in soups; although the control soup with added salt was perceived as saltier and was preferred by consumers over permeate soups. Soup with permeate from cottage cheese was the least liked of all soups, likely due to its sour taste. All other permeate soups scored at parity for liking. These results demonstrate the potential for milk, whey, and delactosed permeates from different whey streams to be used as salt substitutes in product applications. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  4. Vacuum birefringence and the x-ray polarization from black-hole accretion disks

    NASA Astrophysics Data System (ADS)

    Caiazzo, Ilaria; Heyl, Jeremy

    2018-04-01

    In the next decade, x-ray polarimetry will open a new window on the high-energy Universe, as several missions that include an x-ray polarimeter are currently under development. Observations of the polarization of x rays coming from the accretion disks of stellar-mass and supermassive black holes are among the new polarimeters' major objectives. In this paper, we show that these observations can be affected by the quantum electrodynamic (QED) effect of vacuum birefringence: after an x-ray photon is emitted from the accretion disk, its polarization changes as the photon travels through the accretion disk's magnetosphere, as a result of the vacuum becoming birefringent in the presence of a magnetic field. We show that this effect can be important for black holes in the energy band of the upcoming polarimeters and has to be taken into account in a complete model of the x-ray polarization that we expect to detect from black-hole accretion disks, both for stellar mass and for supermassive black holes. We find that, for a chaotic magnetic field in the disk, QED can significantly decrease the linear polarization fraction of edge-on photons, depending on the spin of the hole and on the strength of the magnetic field. This effect can provide, for the first time, a direct way to probe the magnetic field strength close to the innermost stable orbit of black-hole accretion disks and to study the role of magnetic fields in astrophysical accretion in general.

  5. The Hyper-Angular Rainbow Polarimeter (HARP) CubeSat Observatory and the Characterization of Cloud Properties

    NASA Astrophysics Data System (ADS)

    Neilsen, T. L.; Martins, J. V.; Fernandez Borda, R. A.; Weston, C.; Frazier, C.; Cieslak, D.; Townsend, K.

    2015-12-01

    The Hyper-Angular Rainbow Polarimeter HARP instrument is a wide field-of-view imager that splits three spatially identical images into three independent polarizers and detector arrays.This technique achieves simultaneous imagery of the same ground target in three polarization states and is the key innovation to achieve high polarimetric accuracy with no moving parts. The spacecraft consists of a 3U CubeSat with 3-axis stabilization designed to keep the image optics pointing nadir during data collection but maximizing solar panel sun pointing otherwise. The hyper-angular capability is achieved by acquiring overlapping images at very fast speeds.An imaging polarimeter with hyper-angular capability can make a strong contribution to characterizing cloud properties. Non-polarized multi-angle measurements have been shown to besensitive to thin cirrus and can be used to provide climatology ofthese clouds. Adding polarization and increasing the number ofobservation angles allows for the retrieval of the complete sizedistribution of cloud droplets, including accurate information onthe width of the droplet distribution in addition to the currentlyretrieved effective radius.The HARP mission is funded by the NASA Earth Science Technology Office as part of In-Space Validation of Earth Science Technologies (InVEST) program. The HARP instrument is designed and built by a team of students and professionals lead by Dr. Vanderlei Martines at University of Maryland, Baltimore County. The HARP spacecraft is designed and built by a team of students and professionals and The Space Dynamics Laboratory.

  6. Conformal correlation functions in the Brownian loop soup

    NASA Astrophysics Data System (ADS)

    Camia, Federico; Gandolfi, Alberto; Kleban, Matthew

    2016-01-01

    We define and study a set of operators that compute statistical properties of the Brownian loop soup, a conformally invariant gas of random Brownian loops (Brownian paths constrained to begin and end at the same point) in two dimensions. We prove that the correlation functions of these operators have many of the properties of conformal primaries in a conformal field theory, and compute their conformal dimension. The dimensions are real and positive, but have the novel feature that they vary continuously as a periodic function of a real parameter. We comment on the relation of the Brownian loop soup to the free field, and use this relation to establish that the central charge of the loop soup is twice its intensity.

  7. Characteristics of an Imaging Polarimeter for the Powell Observatory

    NASA Astrophysics Data System (ADS)

    Hall, Shannon W.; Henson, Gary D.

    2010-07-01

    A dual-beam imaging polarimeter has been built for use on the 14-inch Schmidt-Cassegrain telescope at the ETSU Harry D. Powell Observatory. The polarimeter includes a rotating half-wave plate and a Wollaston prism to separate light into two orthogonal linearly polarized rays. A thermoelectrically cooled CCD camera is used to detect the modulated polarized light. We present here measurements of the polarization of polarimetric standard stars. By measuring unpolarized and polarized standard stars we are able to establish the instrumental polarization and the efficiency of the instrument. The polarimeter will initially be used as a dedicated instrument in an ongoing project to monitor the eclipsing binary star, Epsilon Aurigae.

  8. POET: POlarimeters for Energetic Transients

    NASA Technical Reports Server (NTRS)

    Hill, J. E.; McConnell, M. L.; Bloser, P.; Legere, J.; Macri, J.; Ryan, J.; Barthelmy, S.; Angelini, L.; Sakamoto, T.; Black, J. K.; hide

    2008-01-01

    POET (Polarimeters for Energetic Transients) is a Small Explorer mission concept proposed to NASA in January 2008. The principal scientific goal of POET is to measure GRB polarization between 2 and 500 keV. The payload consists of two wide FoV instruments: a Low Energy Polarimeter (LEP) capable of polarization measurements in the energy range from 2-15 keV and a high energy polarimeter (Gamma-Ray Polarimeter Experiment - GRAPE) that will measure polarization in the 60-500 keV energy range. Spectra will be measured from 2 keV up to 1 MeV. The POET spacecraft provides a zenith-pointed platform for maximizing the exposure to deep space. Spacecraft rotation will provide a means of effectively dealing with systematics in the polarization response. POET will provide sufficient sensitivity and sky coverage to measure statistically significant polarization for up to 100 GRBs in a two-year mission. Polarization data will also be obtained for solar flares, pulsars and other sources of astronomical interest.

  9. PoET: Polarimeters for Energetic Transients

    NASA Technical Reports Server (NTRS)

    McConnell, Mark; Barthelmy, Scott; Hill, Joanne

    2008-01-01

    This presentation focuses on PoET (Polarimeters for Energetic Transients): a Small Explorer mission concept proposed to NASA in January 2008. The principal scientific goal of POET is to measure GRB polarization between 2 and 500 keV. The payload consists of two wide FoV instruments: a Low Energy Polarimeter (LEP) capable of polarization measurements in the energy range from 2-15 keV and a high energy polarimeter (Gamma-Ray Polarimeter Experiment - GRAPE) that will measure polarization in the 60-500 keV energy range. Spectra will be measured from 2 keV up to 1 MeV. The PoET spacecraft provides a zenith-pointed platform for maximizing the exposure to deep space. Spacecraft rotation will provide a means of effectively dealing with systematics in the polarization response. PoET will provide sufficient sensitivity and sky coverage to measure statistically significant polarization for up to 100 GRBs in a two-year mission. Polarization data will also be obtained for solar flares, pulsars and other sources of astronomical interest.

  10. A high-energy Compton polarimeter for the POET SMEX mission

    NASA Astrophysics Data System (ADS)

    Bloser, Peter F.; McConnell, Mark L.; Legere, Jason S.; Ertley, Camden D.; Hill, Joanne E.; Kippen, Marc; Ryan, James M.

    2014-07-01

    The primary science goal of the Polarimeters for Energetic Transients (POET) mission is to measure the polarization of gamma-ray bursts over a wide energy range, from X rays to soft gamma rays. The higher-energy portion of this band (50 - 500 keV) will be covered by the High Energy Polarimeter (HEP) instrument, a non-imaging, wide field of view Compton polarimeter. Incident high-energy photons will Compton scatter in low-Z, plastic scintillator detector elements and be subsequently absorbed in high-Z, CsI(Tl) scintillator elements; polarization is detected by measuring an asymmetry in the azimuthal scatter angle distribution. The HEP design is based on our considerable experience with the development and flight of the Gamma-Ray Polarimeter Experiment (GRAPE) balloon payload. We present the design of the POET HEP instrument, which incorporates lessons learned from the GRAPE balloon design and previous work on Explorer proposal efforts, and its expected performance on a two-year SMEX mission.

  11. Two Long-Wave Infrared Spectral Polarimeters for Use in Understanding Polarization Phenomenology

    DTIC Science & Technology

    2002-05-01

    3550 Aberdeen SE Kirtland Air Force Base, New Mexico 87117 Abstract. Spectrally varying long-wave infrared ( LWIR ) polarization measurements can be used...to identify materials and to discriminate samples from a cluttered background. Two LWIR instruments have been built and fielded by the Air Force...Research Laboratory: a multispectral LWIR imaging polarimeter (LIP) and a full-Stokes Fourier transform in- frared (FTIR) spectral polarimeter (FSP

  12. Using a polarizing film in the manufacture of panoramic Stokes polarimeters at the Main Astronomical Observatory of NAS of Ukraine

    NASA Astrophysics Data System (ADS)

    Syniavskyi, I.; Ivanov, Yu.; Vidmachenko, A. P.; Sergeev, A.

    2015-08-01

    The construction of an imaging Stokes-polarimeter in the MAO NAS of Ukraine is proposed. It allows measuring the three components of the Stokes vector simultaneously in large FOV without restrictions on the relative aperture of the system. Moreover, the polarimeter can be converted to a low resolution spectropolarimeter by placement into optical axis of the transparence diffraction grating.

  13. Talinum triangulare Whole wheat meal fortified with soy flour consumed with Talinum triangulare (gbure) soup glycemic index and the test human subjects' lipid profiles.

    PubMed

    Emaleku, Sunday Adeola; Omueti, Olusola D; Emaleku, Godsent Oluwakemi

    2017-08-24

    Cardiovascular diseases (CVDs) and diabetes mellitus (DM) are some of the leading causes of death in the world, and diet has roles in their etiology. This research study therefore investigates the glycemic index (GI) of soy flour fortified whole wheat meal (SFFWWM) consumed with Talinum triangulare (gbure) soup and the effects of the meal on the lipid profiles of the test human subjects. The control human subjects and test human subjects were fed D-glucose (DG) and whole wheat meal (WWM) with Talinum triangulare soup respectively on the first day of the experiment, and SFFWWM with the same soup the next day (for test subjects only) after 10-12h overnight fasting. Blood glucose levels of the subjects were taken before and 2h after meals' consumption at 30min interval and blood samples collected for lipid profiles evaluations. The result of the study showed that; SFFWWM consumed with Talinum trianguilare soup has a non-significant lower GI than WWM consumed with the same soup, but a significant lower GI than DG at (P<0.05). Furthermore, there was no significant difference in lipid profiles of the test human subjects between when they consumed WWM and SFFWWM with the soup however, SFFWWM reduced TC, TG, LDL-C and VDL-C and increased HDL-C and TP than WMM at (P<0.05). In addition, GI is positively correlated with TC, TG, LDL-C and VLDL-C, but is negatively correlated with TP and HDL-C. It can therefore be concluded that; fortifying WWM with soy flour would reduce the risk factors of CVDs and DM, the diseases recently claiming thousands of today. Copyright © 2017 Diabetes India. Published by Elsevier Ltd. All rights reserved.

  14. An Outbreak of Norovirus Infection from Shellfish Soup Due to Unforeseen Insufficient Heating During Preparation.

    PubMed

    Lunestad, Bjørn Tore; Maage, Amund; Roiha, Irja Sunde; Myrmel, Mette; Svanevik, Cecilie Smith; Duinker, Arne

    2016-12-01

    Norovirus causes large outbreaks involving all age groups and are considered the most common cause of infectious foodborne diseases worldwide. The aim of this study was to describe a norovirus outbreak connected to insufficient heat treatment during preparation of a shellfish soup in serving portions, during a company Christmas celebration in Norway, December 2013. A questionnaire sent to the employees, showed that 67 % (n = 43) of the celebration participants, reported gastrointestinal symptoms including stomach pain, vomiting, diarrhoea and light fever in the period between 24 and 48 h post celebration. Several dishes were served, including shellfish soup made with carpet shell clams (Tapes rhomboides) in porcelain cups. Consuming this soup, was the only significant risk factor for infection. Norovirus GI and GII were detected in the remaining raw shellfish. To mimic the time and temperature obtained during bivalve soup preparation, raw chopped shellfish tissue and raw cepa onion were added in porcelain cups tempered to 20 °C. To each of these cups, boiling soup base was added. The temperature in the shellfish tissue was continuously recorded, and showed a maximum of 49 °C in the period between 3 and 7 min after adding the boiling soup base. After 1 h the temperature was 30 °C. This time and temperature combination was obviously not sufficient for inactivation of norovirus present in the shellfish tissue. In conclusion, the heat-absorbing capacity of cold ingredients, utensils and table wear porcelain should not be underestimated during food production. Consumers who want to avoid eating raw shellfish, should not assume that the shellfish tissue in preparation as described in our study is adequately heat treated.

  15. Paracrine Effects of Bone Marrow Soup Restore Organ Function, Regeneration, and Repair in Salivary Glands Damaged by Irradiation

    PubMed Central

    Tran, Simon D.; Liu, Younan; Xia, Dengsheng; Maria, Ola M.; Khalili, Saeed; Wang, Renee Wan-Jou; Quan, Vu-Hung; Hu, Shen; Seuntjens, Jan

    2013-01-01

    Background There are reports that bone marrow cell (BM) transplants repaired irradiated salivary glands (SGs) and re-established saliva secretion. However, the mechanisms of action behind these reports have not been elucidated. Methods To test if a paracrine mechanism was the main effect behind this reported improvement in salivary organ function, whole BM cells were lysed and its soluble intracellular contents (termed as “BM Soup”) injected into mice with irradiation-injured SGs. The hypothesis was that BM Soup would protect salivary cells, increase tissue neovascularization, function, and regeneration. Two minor aims were also tested a) comparing two routes of delivering BM Soup, intravenous (I.V.) versus intra-glandular injections, and b) comparing the age of the BM Soup’s donors. The treatment-comparison group consisted of irradiated mice receiving injections of living whole BM cells. Control mice received irradiation and injections of saline or sham-irradiation. All mice were followed for 8 weeks post-irradiation. Results BM Soup restored salivary flow rates to normal levels, protected salivary acinar, ductal, myoepithelial, and progenitor cells, increased cell proliferation and blood vessels, and up-regulated expression of tissue remodeling/repair/regenerative genes (MMP2, CyclinD1, BMP7, EGF, NGF). BM Soup was as an efficient therapeutic agent as injections of live BM cells. Both intra-glandular or I.V. injections of BM Soup, and from both young and older mouse donors were as effective in repairing irradiated SGs. The intra-glandular route reduced injection frequency/dosage by four-fold. Conclusion BM Soup, which contains only the cell by-products, can be advantageously used to repair irradiation-damaged SGs rather than transplanting whole live BM cells which carry the risk of differentiating into unwanted/tumorigenic cell types in SGs. PMID:23637870

  16. Japanese traditional miso soup attenuates salt-induced hypertension and its organ damage in Dahl salt-sensitive rats.

    PubMed

    Yoshinaga, Mariko; Toda, Natsuko; Tamura, Yuki; Terakado, Shouko; Ueno, Mai; Otsuka, Kie; Numabe, Atsushi; Kawabata, Yukari; Uehara, Yoshio

    2012-09-01

    We investigated the effects of long-term miso soup drinking on salt-induced hypertension in Dahl salt-sensitive (Dahl S) rats. Dahl S rats were divided into four groups that consumed 1) water, 2) a 0.9% NaCl solution, 3) a 1.3% sodium NaCl solution, or 4) miso soup containing 1.3% NaCl. They were followed for 8 wk. Systolic blood pressure and hypertensive organ damage were determined. Systolic blood pressure increased in an age- and dose-dependent manner in Dahl S rats drinking salt solutions. The systolic blood pressure increase was significantly less in the Dahl S rats that drank miso soup, although the ultimate cumulative salt loading was greater than that in the Dahl S rats given the 1.3% NaCl solution. This blood pressure decrease was associated with a morphologic attenuation of glomerular sclerosis in the kidney and collagen infiltration in the heart. Urinary protein excretions were less in the miso group than in the rats given the 1.3% NaCl solution. The fractional excretion of sodium was increased and that of potassium was decreased in Dahl S rats given the 1.3% NaCl solution, and these effects were reversed in rats given miso soup toward the values of the control. We found that long-term miso soup drinking attenuates the blood pressure increase in salt-induced hypertension with organ damage. This may be caused by a possible retardation of sodium absorption in the gastrointestinal tract or by the direct effects of nutrients in the miso soup from soybeans. The decrease was associated with decreases in cardiovascular and renal damage. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. Associations between the intake of miso soup and Japanese pickles and the estimated 24-hour urinary sodium excretion: a population-based cross-sectional study.

    PubMed

    Wakasugi, Minako; James Kazama, Junichiro; Narita, Ichiei

    2015-01-01

    In Japan, reducing the consumption of miso soup and Japanese pickles, both traditional Japanese dishes, is recommended in order to decrease dietary salt intake. With the Westernization of dietary habits, however, these dishes are now consumed less frequently, and thus a reduction in their effect on sodium intake is suspected. This study examined cross-sectional associations between the frequency of intake of miso soup and Japanese pickles and the estimated 24-hour urine sodium excretion using data obtained from health examination surveys conducted in 2013 in Sado City, Japan. The level of daily salt intake was estimated based on spot urine sodium and creatinine measurements. The frequency of intake of miso soup and Japanese pickles was determined using a self-reported questionnaire. Multiple linear regression models were used to assess associations. Among a total of 8,821 participants (3,956 men; age range, 19-97 years), the mean daily salt intake was 9.4 g/day. The frequency of intake of miso soup and Japanese pickles increased with age and was associated with the level of daily salt intake (p for trend <0.0001). A linear regression model analysis adjusted for age, sex, body mass index, hypertension, diabetes, hypercholesterolemia and chronic kidney disease revealed that daily salt intake was associated with the frequency of intake of miso soup (p<0.0001) and Japanese pickles (p<0.0001) in all age groups, except those ≥ 80 years of age. These findings suggest that reducing the consumption of miso soup and Japanese pickles may be an effective approach for decreasing the level of dietary salt intake in the general Japanese population, although not in octogenarians or nonagenarians.

  18. Salt reduction in vegetable soup does not affect saltiness intensity and liking in the elderly and children

    PubMed Central

    Gonçalves, Carla; Monteiro, Sérgio; Padrão, Patrícia; Rocha, Ada; Abreu, Sandra; Pinho, Olívia; Moreira, Pedro

    2014-01-01

    Study background Reduction of added salt levels in soups is recommended. We evaluated the impact of a 30% reduction of usual added salt in vegetable soups on elderly and children's saltiness and liking evaluation. Methods Subjects were elderly and recruited from two public nursing homes (29 older adults, 79.7±8.9 years), and preschool children recruited from a public preschool (49 children, 4.5±1.3 years). This study took place in institutional lunchrooms. Through randomization and crossover, the subjects participated in two sensory evaluation sessions, on consecutive days, to assess perceived saltiness intensity (elderly sample) and liking (elderly and children samples) of a vegetable soup with baseline salt content and with a 30% salt reduction. Elderly rated perceived liking through a 10 cm visual analogue scale [‘like extremely’ (1) to ‘dislike extremely’ (10)] and children through a five-point facial scale [‘dislike very much’ (1) to ‘like very much’ (5)]. Results After 30% added salt reduction in vegetable soup, there were no significant differences in saltiness noted by the elderly (p=0.150), and in perceived liking by children (p=0.160) and elderly (p=0.860). Conclusions A 30% salt reduction in vegetable soup may be achieved without compromising perceived saltiness and liking in children and the elderly. PMID:25317121

  19. Identification of the active components in Bone Marrow Soup: a mitigator against irradiation-injury to salivary glands

    PubMed Central

    Fang, Dongdong; Hu, Shen; Liu, Younan; Quan, Vu-Hung; Seuntjens, Jan; Tran, Simon D.

    2015-01-01

    In separate studies, an extract of soluble intracellular contents from whole bone marrow cells, named “Bone Marrow (BM) Soup”, was reported to either improve cardiac or salivary functions post-myocardial infarction or irradiation (IR), respectively. However, the active components in BM Soup are unknown. To demonstrate that proteins were the active ingredients, we devised a method using proteinase K followed by heating to deactivate proteins and for safe injections into mice. BM Soup and “deactivated BM Soup” were injected into mice that had their salivary glands injured with 15Gy IR. Control mice received either injections of saline or were not IR. Results at week 8 post-IR showed the ‘deactivated BM Soup’ was no better than injections of saline, while injections of native BM Soup restored saliva flow, protected salivary cells and blood vessels from IR-damage. Protein arrays detected several angiogenesis-related factors (CD26, FGF, HGF, MMP-8, MMP-9, OPN, PF4, SDF-1) and cytokines (IL-1ra, IL-16) in BM Soup. In conclusion, the native proteins (but not the nucleic acids, lipids or carbohydrates) were the therapeutic ingredients in BM Soup for functional salivary restoration following IR. This molecular therapy approach has clinical potential because it is theoretically less tumorigenic and immunogenic than cell therapies. PMID:26526154

  20. Recipe standardization, nutrient composition and sensory evaluation of waterleaf (Talinum triangulare) and wild spinach (Gnetum africanum) soup "afang" commonly consumed in South-south Nigeria.

    PubMed

    Alozie, Yetunde E; Ene-Obong, Henrietta N

    2018-01-01

    One hundred recipes of waterleaf and wild spinach soup (afang) consumed among the Ibibios in South-south Nigeria were collected through interview and questionnaire from indigenous homemakers and food sellers, harmonized, standardized, prepared and their nutrient content calculated. Mean weights of ingredients were calculated to obtain the control recipe. Major ingredients in the soup were analyzed chemically. Edible portions, retention factors to be applied in recipe calculation were determined. Sensory evaluation was conducted on five of the most preferred recipes on a nine-point hedonic scale. Edible coefficients of major foods ranged between 0.32 and 0.95. Significant changes (p<0.05) in nutrients were observed between raw and cooked ingredients and recipes. Afang soup had 67.9% moisture; protein, 12.7% and energy, 169kcal. Fat contributed 57% of the total energy. Consumption of adequate quantities of afang soup will contribute substantially to Recommended Nutrient Intake of protein and micronutrients which will further increase with additional fish/meat. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Influence of full cream milk powder on the characteristics of sweet potato puree instant cream soup

    NASA Astrophysics Data System (ADS)

    Sunyoto, Marleen; Djali, Mohamad; Dwiastuti, Intan Btari

    2018-02-01

    A ready to use food such as instant cream soup become the most suitable choice for those who prefer being practical and also can be applied in any emergency situation such as areas affected by disaster. The adding of milk powder as the main ingredient in cream soup creates a complex bounding of fat and starch which complicates the rehydration process and affects other physical appearance. This research was aimed to find the proper concentration of full cream milk powder concentration to obtain the best characteristics of instant cream soup of dried sweet potato puree. The method used in this research was randomized block design with 6 treatments (12.5%, 15%, 17.5%, 20%, 22.5% and 25%, with an addition of full cream milk powder) and twice repetition. Instant cream soup with 20% of full cream milk powder concentration gave the best physical and chemical characteristics. The physical and chemical characteristic shows that it has 6% water content, 95.47% rehydration value, 18% protein, 20.7% fat, 1080.25 cP viscosity and 30.5% rendement.

  2. Effect of pilot-scale aseptic processing on tomato soup quality parameters.

    PubMed

    Colle, Ines J P; Andrys, Anna; Grundelius, Andrea; Lemmens, Lien; Löfgren, Anders; Buggenhout, Sandy Van; Loey, Ann; Hendrickx, Marc Van

    2011-01-01

    Tomatoes are often processed into shelf-stable products. However, the different processing steps might have an impact on the product quality. In this study, a model tomato soup was prepared and the impact of pilot-scale aseptic processing, including heat treatment and high-pressure homogenization, on some selected quality parameters was evaluated. The vitamin C content, the lycopene isomer content, and the lycopene bioaccessibility were considered as health-promoting attributes. As a structural characteristic, the viscosity of the tomato soup was investigated. A tomato soup without oil as well as a tomato soup containing 5% olive oil were evaluated. Thermal processing had a negative effect on the vitamin C content, while lycopene degradation was limited. For both compounds, high-pressure homogenization caused additional losses. High-pressure homogenization also resulted in a higher viscosity that was accompanied by a decrease in lycopene bioaccessibility. The presence of lipids clearly enhanced the lycopene isomerization susceptibility and improved the bioaccessibility. The results obtained in this study are of relevance for product formulation and process design of tomato-based food products. © 2011 Institute of Food Technologists®

  3. The large-scale structure of the Universe.

    PubMed

    Springel, Volker; Frenk, Carlos S; White, Simon D M

    2006-04-27

    Research over the past 25 years has led to the view that the rich tapestry of present-day cosmic structure arose during the first instants of creation, where weak ripples were imposed on the otherwise uniform and rapidly expanding primordial soup. Over 14 billion years of evolution, these ripples have been amplified to enormous proportions by gravitational forces, producing ever-growing concentrations of dark matter in which ordinary gases cool, condense and fragment to make galaxies. This process can be faithfully mimicked in large computer simulations, and tested by observations that probe the history of the Universe starting from just 400,000 years after the Big Bang.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yokosawa, A.

    Production of polarized antiproton beams at Fermilab from the parity violating decay of antilambdas is discussed. Use of polarimeters such as the Coulomb-Nuclear and the Primakoff-Effect polarimeters is also mentioned.

  5. 5 MeV Mott Polarimeter Development at Jefferson Lab

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Price, J. S.; Sinclair, C. K.; Cardman, L. S.

    1997-01-01

    Low energy (E{sub k}=100 keV) Mott scattering polarimeters are ill- suited to support operations foreseen for the polarized electron injector at Jefferson Lab. One solution is to measure the polarization at 5 MeV where multiple and plural scattering are unimportant and precision beam monitoring is straightforward. The higher injector beam current offsets the lower cross-sections. Recent improvements in the CEBAF injector polarimeter scattering chamber have improved signal to noise.

  6. Design and construction of a high-energy photon polarimeter

    NASA Astrophysics Data System (ADS)

    Dugger, M.; Ritchie, B. G.; Sparks, N.; Moriya, K.; Tucker, R. J.; Lee, R. J.; Thorpe, B. N.; Hodges, T.; Barbosa, F. J.; Sandoval, N.; Jones, R. T.

    2017-09-01

    We report on the design and construction of a high-energy photon polarimeter for measuring the degree of polarization of a linearly-polarized photon beam. The photon polarimeter uses the process of pair production on an atomic electron (triplet production). The azimuthal distribution of scattered atomic electrons following triplet production yields information regarding the degree of linear polarization of the incident photon beam. The polarimeter, operated in conjunction with a pair spectrometer, uses a silicon strip detector to measure the recoil electron distribution resulting from triplet photoproduction in a beryllium target foil. The analyzing power ΣA for the device using a 75 μm beryllium converter foil is about 0.2, with a relative systematic uncertainty in ΣA of 1.5%.

  7. Modification of the B Ration for the Arctic and Desert

    DTIC Science & Technology

    1984-06-01

    are an integral part of the B Ration. Items are nonfat dry milk, egg mix, onions, green peppers, instant soup mixes, instant applesauce and fruit...BACON (G-1) BREAD HAKGARINE STRAWIIFRIIV JAM PEANUT lUJTTEU COFFEE (A-2) COCOA LUNCH TOMATO VEGKTAbLE NOODLE SOUP (I-S) U...A-2) TEA CHERRY BEVERAGE <A-1) DINNER BEEF NOODLE SOUP (i-1) U/CRACKERS ^SCALLOPED HAM AND POTATOES (0-33) ’■’*VEGETABLE MEDLEY (J-24) BREAD

  8. Fast food tips (image)

    MedlinePlus

    ... at places that offer a variety of salads, soups, and vegetables to help maintain your best health. ... at places that offer a variety of salads, soups, and vegetables to help maintain your best health.

  9. 76 FR 38641 - Procurement List; Proposed Additions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-01

    ... aggregated by the General Services Administration. NSN: 8940-00-NIB-0094--Soup, Shelf-Stable, Cream of Mushroom, Low Sodium. NSN: 8940-00-NIB-0095--Soup, Shelf-Stable, Cream of Chicken. NPA: Cambridge...

  10. HAWCPol: a first-generation far-infrared polarimeter for SOFIA

    NASA Astrophysics Data System (ADS)

    Dowell, C. Darren; Cook, Brant T.; Harper, D. Al; Lin, Lung-Sheng; Looney, Leslie W.; Novak, Giles; Stephens, Ian; Berthoud, Marc; Chuss, David T.; Crutcher, Richard M.; Dotson, Jessie L.; Hildebrand, Roger H.; Houde, Martin; Jones, Terry J.; Krejny, Megan; Lazarian, Alexandre; Moseley, S. Harvey; Tassis, Kostas; Vaillancourt, John E.; Werner, Michael W.

    2010-07-01

    We describe our ongoing project to build a far-infrared polarimeter for the HAWC instrument on SOFIA. Far-IR polarimetry reveals unique information about magnetic fields in dusty molecular clouds and is an important tool for understanding star formation and cloud evolution. SOFIA provides flexible access to the infrared as well as good sensitivity to and angular resolution of continuum emission from molecular clouds. We are making progress toward outfitting HAWC, a first-generation SOFIA camera, with a four-band polarimeter covering 50 to 220 microns wavelength. We have chosen a conservative design which uses quartz half-wave plates continuously rotating at ~0.5 Hz, ball bearing suspensions, fixed wire-grid polarizers, and cryogenic motors. Design challenges are to fit the polarimeter into a volume that did not originally envision one, to minimize the heating of the cryogenic optics, and to produce negligible interference in the detector system. Here we describe the performance of the polarimeter measured at cryogenic temperature as well as the basic method we intend for data analysis. We are on track for delivering this instrument early in the operating lifetime of SOFIA.

  11. Analysis of the new polarimeter for the Marshall Space Flight Center vector magnetograph

    NASA Technical Reports Server (NTRS)

    West, E. A.

    1985-01-01

    The magnetograph was upgraded in both electronic control of the magnetograph hardware and in the polarization optics. The problems associated with the orignal polarimeter were: (1) field of view errors associated with the natural birefringence of the KD*P crystals; (2.) KD*P electrode failure due to the halfwave dc voltage required in one of the operational sequences; and (3) breakdown of the retardation properties of some KD*Ps when exposed to a zero to halfwave modulation (DC) scheme. The new polarimeter gives up the flexibility provided by two variable waveplates to adjust the retardances of the optics for a particular polarization measurement, but solves the problems associated with the original polarimeter. With the addition of the quartz quarterwave plates, a new optical alignment was developed to allow the remaining KD*P to correct for errors in the waveplates. The new optical alignment of the polarimeter is prescribed. The various sources of error, and how those errors are minimized so that the magnetograph can look at the transverse field in real time are discussed.

  12. Early Childhood: From Soup to Science.

    ERIC Educational Resources Information Center

    McIntyre, Margaret, Ed.

    1983-01-01

    Provided are recipes (with accompanying questions and activities) designed to help teachers and parents as they explore science and cooking with children. Recipes include those for orange soup, orange milk shakes, and yogurt. (JN)

  13. Primordial soup was edible: abiotically produced Miller-Urey mixture supports bacterial growth.

    PubMed

    Xie, Xueshu; Backman, Daniel; Lebedev, Albert T; Artaev, Viatcheslav B; Jiang, Liying; Ilag, Leopold L; Zubarev, Roman A

    2015-09-28

    Sixty years after the seminal Miller-Urey experiment that abiotically produced a mixture of racemized amino acids, we provide a definite proof that this primordial soup, when properly cooked, was edible for primitive organisms. Direct admixture of even small amounts of Miller-Urey mixture strongly inhibits E. coli bacteria growth due to the toxicity of abundant components, such as cyanides. However, these toxic compounds are both volatile and extremely reactive, while bacteria are highly capable of adaptation. Consequently, after bacterial adaptation to a mixture of the two most abundant abiotic amino acids, glycine and racemized alanine, dried and reconstituted MU soup was found to support bacterial growth and even accelerate it compared to a simple mixture of the two amino acids. Therefore, primordial Miller-Urey soup was perfectly suitable as a growth media for early life forms.

  14. Episodic memory and appetite regulation in humans.

    PubMed

    Brunstrom, Jeffrey M; Burn, Jeremy F; Sell, Nicola R; Collingwood, Jane M; Rogers, Peter J; Wilkinson, Laura L; Hinton, Elanor C; Maynard, Olivia M; Ferriday, Danielle

    2012-01-01

    Psychological and neurobiological evidence implicates hippocampal-dependent memory processes in the control of hunger and food intake. In humans, these have been revealed in the hyperphagia that is associated with amnesia. However, it remains unclear whether 'memory for recent eating' plays a significant role in neurologically intact humans. In this study we isolated the extent to which memory for a recently consumed meal influences hunger and fullness over a three-hour period. Before lunch, half of our volunteers were shown 300 ml of soup and half were shown 500 ml. Orthogonal to this, half consumed 300 ml and half consumed 500 ml. This process yielded four separate groups (25 volunteers in each). Independent manipulation of the 'actual' and 'perceived' soup portion was achieved using a computer-controlled peristaltic pump. This was designed to either refill or draw soup from a soup bowl in a covert manner. Immediately after lunch, self-reported hunger was influenced by the actual and not the perceived amount of soup consumed. However, two and three hours after meal termination this pattern was reversed - hunger was predicted by the perceived amount and not the actual amount. Participants who thought they had consumed the larger 500-ml portion reported significantly less hunger. This was also associated with an increase in the 'expected satiation' of the soup 24-hours later. For the first time, this manipulation exposes the independent and important contribution of memory processes to satiety. Opportunities exist to capitalise on this finding to reduce energy intake in humans.

  15. Picking up Clues from the Discard Pile (Stereo)

    NASA Technical Reports Server (NTRS)

    2008-01-01

    As NASA's Phoenix Mars Lander excavates trenches, it also builds piles with most of the material scooped from the holes. The piles, like this one called 'Caterpillar,' provide researchers some information about the soil.

    On Aug. 24, 2008, during the late afternoon of the 88th Martian day after landing, Phoenix's Surface Stereo Imager took separate exposures through its left eye and right eye that have been combined into this stereo view. The image appears three dimensional when seen through red-blue glasses.

    This conical pile of soil is about 10 centimeters (4 inches) tall. The sources of material that the robotic arm has dropped onto the Caterpillar pile have included the 'Dodo' and ''Upper Cupboard' trenches and, more recently, the deeper 'Stone Soup' trench.

    Observations of the pile provide information, such as the slope of the cone and the textures of the soil, that helps scientists understand properties of material excavated from the trenches.

    For the Stone Soup trench in particular, which is about 18 centimeters (7 inches) deep, the bottom of the trench is in shadow and more difficult to observe than other trenches that Phoenix has dug. The Phoenix team obtained spectral clues about the composition of material from the bottom of Stone Soup by photographing Caterpillar through 15 different filters of the Surface Stereo Imager when the pile was covered in freshly excavated material from the trench.

    The spectral observation did not produce any sign of water-ice, just typical soil for the site. However, the bigger clumps do show a platy texture that could be consistent with elevated concentration of salts in the soil from deep in Stone Soup. The team chose that location as the source for a soil sample to be analyzed in the lander's wet chemistry laboratory, which can identify soluble salts in the soil.

    The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  16. Picking up Clues from the Discard Pile

    NASA Technical Reports Server (NTRS)

    2008-01-01

    As NASA's Phoenix Mars Lander excavates trenches, it also builds piles with most of the material scooped from the holes. The piles, like this one called 'Caterpillar,' provide researchers some information about the soil.

    On Aug. 24, 2008, during the late afternoon of the 88th Martian day after landing, Phoenix's Surface Stereo Imager took separate exposures through red, green and blue filters that have been combined into this approximately true-color image.

    This conical pile of soil is about 10 centimeters (4 inches) tall. The sources of material that the robotic arm has dropped onto the Caterpillar pile have included the 'Dodo' and ''Upper Cupboard' trenches and, more recently, the deeper 'Stone Soup' trench.

    Observations of the pile provide information, such as the slope of the cone and the textures of the soil, that helps scientists understand properties of material excavated from the trenches.

    For the Stone Soup trench in particular, which is about 18 centimeters (7 inches) deep, the bottom of the trench is in shadow and more difficult to observe than other trenches that Phoenix has dug. The Phoenix team obtained spectral clues about the composition of material from the bottom of Stone Soup by photographing Caterpillar through 15 different filters of the Surface Stereo Imager when the pile was covered in freshly excavated material from the trench.

    The spectral observation did not produce any sign of water-ice, just typical soil for the site. However, the bigger clumps do show a platy texture that could be consistent with elevated concentration of salts in the soil from deep in Stone Soup. The team chose that location as the source for a soil sample to be analyzed in the lander's wet chemistry laboratory, which can identify soluble salts in the soil.

    The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  17. A photoelastic-modulator-based motional Stark effect polarimeter for ITER that is insensitive to polarized broadband background reflections.

    PubMed

    Thorman, A; Michael, C; De Bock, M; Howard, J

    2016-07-01

    A motional Stark effect polarimeter insensitive to polarized broadband light is proposed. Partially polarized background light is anticipated to be a significant source of systematic error for the ITER polarimeter. The proposed polarimeter is based on the standard dual photoelastic modulator approach, but with the introduction of a birefringent delay plate, it generates a sinusoidal spectral filter instead of the usual narrowband filter. The period of the filter is chosen to match the spacing of the orthogonally polarized Stark effect components, thereby increasing the effective signal level, but resulting in the destructive interference of the broadband polarized light. The theoretical response of the system to an ITER like spectrum is calculated and the broadband polarization tolerance is verified experimentally.

  18. Design and construction of a high-energy photon polarimeter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dugger, M.; Ritchie, B. G.; Sparks, N.

    Here, we report on the design and construction of a high-energy photon polarimeter for measuring the degree of polarization of a linearly-polarized photon beam. The photon polarimeter uses the process of pair production on an atomic electron (triplet production). The azimuthal distribution of scattered atomic electrons following triplet production yields information regarding the degree of linear polarization of the incident photon beam. Furthermore, the polarimeter, operated in conjunction with a pair spectrometer, uses a silicon strip detector to measure the recoil electron distribution resulting from triplet photoproduction in a beryllium target foil. The analyzing power Σ A for the devicemore » using a 75 μm beryllium converter foil is about 0.2, with a relative systematic uncertainty in Σ A of 1.5%.« less

  19. Design and construction of a high-energy photon polarimeter

    DOE PAGES

    Dugger, M.; Ritchie, B. G.; Sparks, N.; ...

    2017-06-12

    Here, we report on the design and construction of a high-energy photon polarimeter for measuring the degree of polarization of a linearly-polarized photon beam. The photon polarimeter uses the process of pair production on an atomic electron (triplet production). The azimuthal distribution of scattered atomic electrons following triplet production yields information regarding the degree of linear polarization of the incident photon beam. Furthermore, the polarimeter, operated in conjunction with a pair spectrometer, uses a silicon strip detector to measure the recoil electron distribution resulting from triplet photoproduction in a beryllium target foil. The analyzing power Σ A for the devicemore » using a 75 μm beryllium converter foil is about 0.2, with a relative systematic uncertainty in Σ A of 1.5%.« less

  20. The Hyper-Angular Rainbow Polarimeter (HARP) CubeSat Observatory and the Characterization of Cloud Properties

    NASA Astrophysics Data System (ADS)

    Neilsen, T. L.; Martins, J. V.; Fish, C. S.; Fernandez Borda, R. A.

    2014-12-01

    The Hyper-Angular Rainbow Polarimeter HARP instrument is a wide field-of-view imager that splits three spatially identical images into three independent polarizers and detector arrays. This technique achieves simultaneous imagery of the same ground target in three polarization states and is the key innovation to achieve high polarimetric accuracy with no moving parts. The spacecraft consists of a 3U CubeSat with 3-axis stabilization designed to keep the image optics pointing nadir during data collection but maximizing solar panel sun pointing otherwise. The hyper-angular capability is achieved by acquiring overlapping images at very fast speeds. An imaging polarimeter with hyper-angular capability can make a strong contribution to characterizing cloud properties. Non-polarized multi-angle measurements have been shown to be sensitive to thin cirrus and can be used to provide climatology of these clouds. Adding polarization and increasing the number of observation angles allows for the retrieval of the complete size distribution of cloud droplets, including accurate information on the width of the droplet distribution in addition to the currently retrieved e­ffective radius. The HARP mission is funded by the NASA Earth Science Technology Office as part of In-Space Validation of Earth Science Technologies (InVEST) program. The HARP instrument is designed and built by a team of students and professionals lead by Dr. Vanderlei Martines at University of Maryland, Baltimore County. The HARP spacecraft is designed and built by a team of students and professionals and The Space Dynamics Laboratory.

  1. Influence of higher harmonics of the undulator in X-ray polarimetry and crystal monochromator design.

    PubMed

    Marx-Glowna, Berit; Schulze, Kai S; Uschmann, Ingo; Kämpfer, Tino; Weber, Günter; Hahn, Christoph; Wille, Hans Christian; Schlage, Kai; Röhlsberger, Ralf; Förster, Eckhart; Stöhlker, Thomas; Paulus, Gerhard G

    2015-09-01

    The spectrum of the undulator radiation of beamline P01 at Petra III has been measured after passing a multiple reflection channel-cut polarimeter. Odd and even harmonics up to the 15th order, as well as Compton peaks which were produced by the high harmonics in the spectrum, could been measured. These additional contributions can have a tremendous influence on the performance of the polarimeter and have to be taken into account for further polarimeter designs.

  2. The polarimeter and the multispectral radiometer as remote probes of aerosols

    NASA Technical Reports Server (NTRS)

    Kuriyan, J. G.

    1975-01-01

    Attempts made to establish the viability of the polarimeter as a ground based remote probe of atmospheric aerosols under varying meteorological conditions are reported. Extension radiometer data are also given and a comparison was made with polarimeter data to determine if one could complement/supplement the other. The analyses show that the two instruments are complementary devices and any information obtained from one will greatly facilitate the analysis of the other. Detailed results are given in graphical form.

  3. Free radical interactions between raw materials in dry soup powder.

    PubMed

    Raitio, Riikka; Orlien, Vibeke; Skibsted, Leif H

    2011-12-01

    Interactions at the free radical level were observed between dry ingredients in cauliflower soup powder, prepared by dry mixing of ingredients and rapeseed oil, which may be of importance for quality deterioration of such dry food products. The free radical concentrations of cauliflower soup powder, obtained by electron spin resonance (ESR) spectroscopy, rapidly become smaller during storage (40°C and relative humidity of 75%) than the calculated concentrations of free radicals based on the free radical concentrations of the powder ingredients used to make the soup powder and stored separately under similar conditions. Similarly, free radical concentrations decreased faster when any combination of two powder ingredients (of the three major ingredients of the soup powder) were mixed together and stored at 50°C for 1week than when each powder component was stored separately. Furthermore, yeast extract powder was found to play a key role when free radical interactions between powder ingredients occurred. The incubation of rapeseed oil with powder ingredients at 45°C for 24h, indicated the ability of cauliflower powder to increase the concentration of hydroperoxides in rapeseed oil, while yeast extract powder was found to prevent this hydroperoxide formation. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. The study of heat penetration of kimchi soup on stationary and rotary retorts.

    PubMed

    Cho, Won-Il; Park, Eun-Ji; Cheon, Hee Soon; Chung, Myong-Soo

    2015-03-01

    The aim of this study was to determine the heat-penetration characteristics using stationary and rotary retorts to manufacture Kimchi soup. Both heat-penetration tests and computer simulation based on mathematical modeling were performed. The sterility was measured at five different positions in the pouch. The results revealed only a small deviation of F 0 among the different positions, and the rate of heat transfer was increased by rotation of the retort. The thermal processing of retort-pouched Kimchi soup was analyzed mathematically using a finite-element model, and optimum models for predicting the time course of the temperature and F 0 were developed. The mathematical models could accurately predict the actual heat penetration of retort-pouched Kimchi soup. The average deviation of the temperature between the experimental and mathematical predicted model was 2.46% (R(2)=0.975). The changes in nodal temperature and F 0 caused by microbial inactivation in the finite-element model predicted using the NISA program were very similar to that of the experimental data of for the retorted Kimchi soup during sterilization with rotary retorts. The correlation coefficient between the simulation using the NISA program and the experimental data was very high, at 99%.

  5. The Study of Heat Penetration of Kimchi Soup on Stationary and Rotary Retorts

    PubMed Central

    Cho, Won-Il; Park, Eun-Ji; Cheon, Hee Soon; Chung, Myong-Soo

    2015-01-01

    The aim of this study was to determine the heat-penetration characteristics using stationary and rotary retorts to manufacture Kimchi soup. Both heat-penetration tests and computer simulation based on mathematical modeling were performed. The sterility was measured at five different positions in the pouch. The results revealed only a small deviation of F0 among the different positions, and the rate of heat transfer was increased by rotation of the retort. The thermal processing of retort-pouched Kimchi soup was analyzed mathematically using a finite-element model, and optimum models for predicting the time course of the temperature and F0 were developed. The mathematical models could accurately predict the actual heat penetration of retort-pouched Kimchi soup. The average deviation of the temperature between the experimental and mathematical predicted model was 2.46% (R2=0.975). The changes in nodal temperature and F0 caused by microbial inactivation in the finite-element model predicted using the NISA program were very similar to that of the experimental data of for the retorted Kimchi soup during sterilization with rotary retorts. The correlation coefficient between the simulation using the NISA program and the experimental data was very high, at 99%. PMID:25866751

  6. Nutritional status of men attending a soup kitchen: a pilot study.

    PubMed Central

    Laven, G T; Brown, K C

    1985-01-01

    Nutritional status and socioeconomic characteristics of 49 men attending a soup kitchen in a residential neighborhood of Birmingham, Alabama were determined by interview, anthropometry and laboratory assays. Laboratory or anthropometric evidence of nutrient deficiency was present in 94 per cent of the subjects. Deficiency of ascorbate (63 per cent), folate (35 per cent), and thiamin (29 per cent) was higher in these men than in either patients or presumably healthy adults. Since soup kitchen meals provided insufficient vitamin C and folate, additional sources of these nutrients should be provided. PMID:4040716

  7. The Emergency/Assault Food Packet with the Arctic Supplement. An Evaluation of an Arctic Ration and Assessment of Water Discipline in the Arctic

    DTIC Science & Technology

    1981-12-01

    noodle soup, oatmeal with maple sugar, oatmeal cookie bar, granola bar, and starch jelly Given by increasing median hedonic rating, the ten least...of 8.0 or better. By decreasing hedonic rating, these were cocoa, lemon tea, oatmeal with apples, chicken noodle soup, oatmeal with maple sugar...Sugar 7.37 8.53*+ (87) Soups** Chicken Noodle 7.48 8.53* (60) Beef Vegetable 7.26 8.19* (47) Beverages* * Cocoa Beverage Powder 7.68

  8. Importance of Applying Condiments in a Commonly Consumed Food System for Understanding the Association Between Familiarity and Sensory Drivers of Liking: A Study Focused on Doenjang.

    PubMed

    Roh, Soo Hyun; Lee, Soh Min; Kim, Sang Sook; Kim, Kwang-Ok

    2018-02-01

    Doenjang, a Korean traditional fermented soybean paste, is one of the most essential condiments in Korean cuisine. Condiments are rarely consumed as it is, and are generally applied to other foods. The objective of this study was to understand how sensory drivers of liking of Doenjang would be affected according to food forms in which it is evaluated: the original paste form compared with a normally consumed soup form, and to understand the association of familiarity of evaluated food form. Descriptive analysis and consumer acceptability test was performed in 2 consumption forms: the original paste form and the Doenjang soup from. For consumer liking test, elderly consumers who have more experience to traditional Deonjang were compared to the young in their response to Doenjang paste and soup. The descriptive analysis results showed that the characteristic sensory features of the Deonjang samples were little affected based on the food system in which it was evaluated. However, when the paste was applied in soup, the intensities of the characteristic sensory features were reduced. Acceptability and familiarity of traditional type Doenjang samples for the young and for the elderly consumers were very similar in paste, but it differed when the samples were evaluated in soup. Thus, expectation difference between the young and the elderly was better revealed in soup, a more common food form consumed in practice. The results of this study indicate the importance of understanding sensory drivers of liking for a condiment such as Doenjang in their commonly consumed forms. Compared to the original condiment form, expectation difference between the young and the elderly were better revealed in Deonjang soup, a food form normally consumed in practice. Thus, the results of this study reinforced the importance of investigating sensory drivers of liking for a condiment in a food form that is normally consumed in practice for accurate understanding on consumer preference. © 2018 Institute of Food Technologists®.

  9. Selected Vegetables/Sun's Soup (PDQ®)—Patient Version

    Cancer.gov

    Expert-reviewed information summary about the use of selected vegetables/Sun's soup as a treatment for people with cancer. Note: The information in this summary is no longer being updated and is provided for reference purposes only.

  10. 21 CFR 102.26 - Frozen “heat and serve” dinners.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... servings of food (e.g., soup, bread or rolls, beverage, dessert). (b) The common or usual name of the food... section contained in the package (e.g., onion soup, enriched white bread, and artificially flavored...

  11. POLIX: A Thomson X-ray polarimeter for a small satellite mission

    NASA Astrophysics Data System (ADS)

    Paul, Biswajit; Gopala Krishna, M. R.; Puthiya Veetil, Rishin

    2016-07-01

    POLIX is a Thomson X-ray polarimeter for a small satellite mission of ISRO. The instrument consists of a collimator, a scatterer and a set proportional counters to detect the scattered X-rays. We will describe the design, specifications, sensitivity, and development status of this instrument and some of the important scientific goals. This instrument will provide unprecedented opportunity to measure X-ray polarisation in the medium energy range in a large number of sources of different classes with a minimum detectable linear polarisation degree of 2-3%. The prime objects for observation with this instrument are the X-ray bright accretion powered neutron stars, accreting black holes in different spectral states, rotation powered pulsars, magnetars, and active galactic nuclei. This instrument will be a bridge between the soft X-ray polarimeters and the Compton polarimeters.

  12. Design of the Polarimeter for the Fibre Arrayed Solar Optical Telescope

    NASA Astrophysics Data System (ADS)

    Dun, Guang-tao; Qu, Zhong-quan

    2013-01-01

    The theoretical design of the polarimeter used for the Fibre Arrayed Solar Optical Telescope (FASOT) is described. It has the following characteris- tics: (1) It is provided with the function of optical polarization switching, which makes the high-effciency polarimetry possible; (2) In the waveband of 750 nm, the polarimetric effciency is higher than 50% for the every Stokes parameter, and higher than 86.6% for the total polarization, thus an observer can make the simultaneous polarization measurements on multiple magnetosensitive lines in such a broad range of wavelength; (3) According to the selected photospheric and chromospheric lines, the measurement can be focused on either linear polarization or circular polarization; (4) The polarimeter has a loose tolerance on the manufacturing technology of polarimetric elements and installation errors. All this makes this polarimeter become a high-performance polarimetric device.

  13. Characteristic Flavor of Traditional Soup Made by Stewing Chinese Yellow-Feather Chickens.

    PubMed

    Qi, Jun; Liu, Deng-Yong; Zhou, Guang-Hong; Xu, Xing-Lian

    2017-09-01

    The traditional recipe for Chinese chicken soup creates a popular taste of particular umami and aroma. The present study investigated the effects of stewing time (1, 2, and 3 h) on the principal taste-active and volatile compounds and the overall flavor profile of traditional Chinese chicken soup by measuring the contents of free amino acids (FAAs), 5'-nucleotides, minerals and volatile compounds and by evaluating the taste and aroma profiles using an electronic nose, an electronic tongue and a human panel. Results showed that the major umami-related compounds in the chicken soup were inosine 5'-monophosphate (IMP) and chloride, both of which increased significantly (P < 0.05) during stewing. The taste active values (TAVs) of the equivalent umami concentration (EUC) increased from 4.08 to 9.93 (P < 0.05) after stewing for 3 h. Although the FAA and mineral contents increased significantly (P < 0.05), their TAVs were less than 1. The volatile compounds were mainly hexanal, heptanal, octanal, nonanal, (E)-2-nonanal, (E)-2-decenal, (E,E)-2,4-decadienal, 1-hexanol, and 2-pentyl furan. With the prolonged stewing time, the aldehydes first increased and then decreased significantly (P < 0.05), while 1-hexanol and 2-pentyl furan increased steadily (P < 0.05). The aroma scores of the chicken soup reached the maximum after stewing for 3 h. The discrepancy in overall flavor characteristics tended to stabilize after 2 h of stewing. In general, stewing time has a positive effect on improving the flavor profiles of chicken soup, especially within the first 2 h. © 2017 Institute of Food Technologists®.

  14. Bacteriology of Dehydrated Space Foods 1

    PubMed Central

    Powers, Edmund M.; Ay, Carl; El-Bisi, Hamed M.; Rowley, Durwood B.

    1971-01-01

    The initial bacteriological requirement established in 1964 for space foods by the U.S. Army Natick Laboratories are: a total aerobic plate count (≤ 10,000 per g), a total coliform count (≤ 10 per g), fecal coliforms (negative per gram), fecal streptococci (≤ 20 per g), coagulase-positive staphylococci (negative in 5 g) and salmonellae (negative in 10 g). Of the space foods and prototypes tested during 1968 and 1969, 93% complied with the total aerobic plate count, 98% had less than 1 coliform per g, and 99% were negative for fecal coliforms; 88% complied with the streptococci requirement; 100 and 98% were negative for staphylococci and salmonellae, respectively. Nineteen food samples which did not comply (as indicated parenthetically by actual counts per gram) with the requirements were (i) total aerobic plate count: beef soup and gravy base (18,000), chicken soup and gravy base (57,000), spaghetti with meat sauce (12,100 and 14,000), sugared coffee (> 300,000), chocolate ice cream cubes (20,000), and each of four samples of chocolate candy (12,000 to 61,000); (ii) coliforms: two out of three vanilla milk drinks (16 and 127) and one beef hash bar (14); (iii) fecal coliforms: one sample of chicken soup and gravy base positive; (iv) fecal streptococci: two samples of peanut cubes (40 and 108), coconut cubes (75), chicken soup and gravy base (2,650), beef soup and gravy base (33), and five out of six flavored milk drinks (23 to 300); (v) salmonellae: one each of chicken and beef soup and gravy base were positive. Images PMID:4940878

  15. The effect of ginger and garlic addition during cooking on the volatile profile of grass carp (Ctenopharyngodon idella) soup.

    PubMed

    Li, Jin-Lin; Tu, Zong-Cai; Zhang, Lu; Sha, Xiao-Mei; Wang, Hui; Pang, Juan-Juan; Tang, Ping-Ping

    2016-08-01

    Ginger and garlic have long been used in Asian countries to enhance the flavor and to neutralize any unpleasant odors present in fish soup. The purpose of this study was to evaluate the change in the amount of volatile components present in fish soup compared to boiled water solutions of ginger and garlic. The fish soup was prepared by boiling oil-fried grass carp ( Ctenopharyngodon idella ) with or without ginger and/or garlic. Generally, boiling garlic and ginger in water led to a decrease in the amount of the principal volatile constituents of these spices, together with the formation of some new volatiles such as pentanal, hexanal, and nonanal. The results showed that 16 terpenes present in raw ginger, predominantly camphene, β -phellandrene, β -citral, α -zingiberene, and ( E )-neral, were detected in fish soup with added ginger and thus remained in the solution even after boiling. Similarly, 2-propen-1-ol and three sulfur compounds (allyl sulfide, diallyl disulfide, and diallyl trisulfide) present in raw garlic, were present in trace amounts in the boiled garlic solution, but were present in considerably larger amounts in the boiled fish solution with garlic or garlic plus ginger. In conclusion, the effect of adding spices on the volatile profile of grass carp soup can be attributed to the dissolution of flavor volatiles mainly derived from raw spices into the solution, with few additional volatiles being formed during boiling. In addition, boiling previously fried grass carp with spices led to enhanced volatile levels compared to boiled spice solutions.

  16. Episodic Memory and Appetite Regulation in Humans

    PubMed Central

    Brunstrom, Jeffrey M.; Burn, Jeremy F.; Sell, Nicola R.; Collingwood, Jane M.; Rogers, Peter J.; Wilkinson, Laura L.; Hinton, Elanor C.; Maynard, Olivia M.; Ferriday, Danielle

    2012-01-01

    Psychological and neurobiological evidence implicates hippocampal-dependent memory processes in the control of hunger and food intake. In humans, these have been revealed in the hyperphagia that is associated with amnesia. However, it remains unclear whether ‘memory for recent eating’ plays a significant role in neurologically intact humans. In this study we isolated the extent to which memory for a recently consumed meal influences hunger and fullness over a three-hour period. Before lunch, half of our volunteers were shown 300 ml of soup and half were shown 500 ml. Orthogonal to this, half consumed 300 ml and half consumed 500 ml. This process yielded four separate groups (25 volunteers in each). Independent manipulation of the ‘actual’ and ‘perceived’ soup portion was achieved using a computer-controlled peristaltic pump. This was designed to either refill or draw soup from a soup bowl in a covert manner. Immediately after lunch, self-reported hunger was influenced by the actual and not the perceived amount of soup consumed. However, two and three hours after meal termination this pattern was reversed - hunger was predicted by the perceived amount and not the actual amount. Participants who thought they had consumed the larger 500-ml portion reported significantly less hunger. This was also associated with an increase in the ‘expected satiation’ of the soup 24-hours later. For the first time, this manipulation exposes the independent and important contribution of memory processes to satiety. Opportunities exist to capitalise on this finding to reduce energy intake in humans. PMID:23227200

  17. Preventing gastric sieving by blending a solid/water meal enhances satiation in healthy humans.

    PubMed

    Marciani, Luca; Hall, Nicholas; Pritchard, Susan E; Cox, Eleanor F; Totman, John J; Lad, Mita; Hoad, Caroline L; Foster, Tim J; Gowland, Penny A; Spiller, Robin C

    2012-07-01

    Separation of solids and liquids within the stomach allows faster gastric emptying of liquids compared with solids, a phenomenon known as sieving. We tested the hypothesis that blending a solid and water meal would abolish sieving, preventing the early rapid decrease in gastric volume and thereby enhancing satiety. We carried out 2 separate studies. Study 1 was a 2-way, crossover, satiety study of 22 healthy volunteers who consumed roasted chicken and vegetables with a glass of water (1008 kJ) or the same blended to a soup. They completed satiety visual analogue scales at intervals for 3 h. Study 2 was a 2-way, crossover, mechanistic study of 18 volunteers who consumed the same meals and underwent an MRI to assess gastric emptying, gallbladder contraction, and small bowel water content (SBWC) at intervals for 3 h. In Study 1, the soup meal was associated with reduced hunger (P = 0.02). In Study 2, the volume of the gastric contents after the soup meal decreased more slowly than after the solid/liquid meal (P = 0.0003). The soup meal caused greater gallbladder contraction (P < 0.04). SBWC showed a biphasic response with an initial "gastric" phase during which SBWC was greater when the solid/liquid meal was consumed (P < 0.001) and a later "small bowel" phase when SBWC was greater when the soup meal was consumed (P < 0.01). Blending the solid/liquid meal to a soup delayed gastric emptying and increased the hormonal response to feeding, which may contribute to enhanced postprandial satiety.

  18. Selected Vegetables/Sun's Soup (PDQ®)—Health Professional Version

    Cancer.gov

    Expert-reviewed information summary about the use of selected vegetables/Sun's soup as a treatment for people with cancer. Note: The information in this summary is no longer being updated and is provided for reference purposes only.

  19. Effect of the consumption of a fruit and vegetable soup with high in vitro carotenoid bioaccessibility on serum carotenoid concentrations and markers of oxidative stress in young men.

    PubMed

    Martínez-Tomás, Rebeca; Larqué, Elvira; González-Silvera, Daniel; Sánchez-Campillo, María; Burgos, María Isabel; Wellner, Anna; Parra, Soledad; Bialek, Lucy; Alminger, Marie; Pérez-Llamas, Francisca

    2012-03-01

    To evaluate the effect of the daily intake of a fruit & vegetable soup with high in vitro bioaccessibility of carotenoids on β-carotene and lycopene serum concentrations. Fourteen healthy young men (24 ± 1 years) received 300 mL/day of a carrot, tomato, and broccoli soup, containing 3.9 mg β-carotene and 4 mg lycopene, for 4 weeks followed by a 4-week washout period. The serum carotenoid response and oxidative markers were analyzed after 3 and 4 weeks of soup consumption and after a 4-week washout. The in vitro bioaccessibility of β-carotene and lycopene was 55 and 43%, respectively, in the soup. Serum β-carotene concentrations were significantly higher than baseline (0.33 ± 0.05 μmol/L) after 3 weeks (0.69 ± 0.06 μmol/L) and 4 weeks (0.78 ± 0.10 μmol/L) of soup consumption (P < 0.001). Serum lycopene was also significantly higher compared with baseline levels (0.26 ± 0.08-0.56 ± 0.04 μmol/L and 0.60 ± 0.04 μmol/L, after 3 and 4 weeks, respectively) (P < 0.001). Although the highest concentration of both carotenoids was found after 4 weeks, the levels were not statistically different from the levels at 3 weeks. A 4-week washout significantly decreased serum carotenoid concentrations, although only β-carotene returned to baseline. Glutathione peroxidase (GPx) increased significantly after soup supplementation compared with baseline, while superoxide dismutase was significantly lower only after 3 weeks. Glutathione reductase, lipid, protein, and DNA oxidative markers remained unchanged. The soup contributed to increasing the concentration of each carotenoid by more than 100% after 3 and 4 weeks of consumption, the maximum increase being observed after 4 weeks. Oxidative markers did not show any variation except for GPx. Serum lycopene half-life was longer than that of β-carotene, which may be important for studies evaluating both carotenoids.

  20. A star-and-sky chopping polarimeter - Design and performance

    NASA Astrophysics Data System (ADS)

    Jain, S. K.; Srinivasulu, G.

    1991-09-01

    A star-and-sky chopping polarimeter is developed for accurate measurements of linear polarization of starlight in the standard astronomical photometric U, B, V, R, and I bands. The instrumental polarization, as determined by observing the standard unpolarized stars, is 0.04 percent. It is possible to use the instrument for the measurements of circular polarization as well. A Unicorn microcomputer controls the various operations of the instrument, acquires the data, and does the on-line data reduction. This paper describes the design and performance of the polarimeter.

  1. Use of Mueller and non-Mueller matrices to describe polarization properties of telescope-based polarimeters

    NASA Astrophysics Data System (ADS)

    Seagraves, P. H.; Elmore, David F.

    1994-09-01

    Systems using optical elements such as linear polarizers, retarders, and mirrors can be represented by Mueller matrices. Some polarimeters include elements with time-varying polarization properties, multiple light beams, light detectors, and signal processing equipment. Standard Mueller matrix forms describing time-varying retarders, and beam splitters are presented, as well as non-Mueller matrices which describe detection and signal processing. These matrices provide a compact and intuitive mathematical description of polarimeter response which can aid in the refining of instrument designs.

  2. Vector magnetic field observations with the Haleakala polarimeter

    NASA Technical Reports Server (NTRS)

    Mickey, D. L.

    1985-01-01

    Several enhancements were recently made to the Haleakala polarimeter. Linear array detectors provide simultaneous resolution over a 3-A wavelength range, with spectral resolution of 40 mA. Optical fibers are now used to carry the intensity-modulated light from the rotating quarter-wave plate polarimeter to the echelle spectrometer, permitting its removal from the spar to a more stable environment. These changes, together with improved quarter-wave plates, reduced systematic errors to a few parts in 10,000 for routine observations. Examples of Stokes profiles and derived magnetic field maps are presented.

  3. New Satellite Project Aerosol-UA: Remote Sensing of Aerosols in the Terrestrial Atmosphere

    NASA Technical Reports Server (NTRS)

    Milinevsky, G.; Yatskiv, Ya.; Degtyaryov, O.; Syniavskyi, I.; Mishchenko, Michael I.; Rosenbush, V.; Ivanov, Yu.; Makarov, A.; Bovchaliuk, A.; Danylevsky, V.; hide

    2016-01-01

    We discuss the development of the Ukrainian space project Aerosol-UA which has the following three main objectives: (1) to monitor the spatial distribution of key characteristics of terrestrial tropospheric and stratospheric aerosols; (2) to provide a comprehensive observational database enabling accurate quantitative estimates of the aerosol contribution to the energy budget of the climate system; and (3) quantify the contribution of anthropogenic aerosols to climate and ecological processes. The remote sensing concept of the project is based on precise orbital measurements of the intensity and polarization of sunlight scattered by the atmosphere and the surface with a scanning polarimeter accompanied by a wide-angle multispectral imager-polarimeter. Preparations have already been made for the development of the instrument suite for the Aerosol-UA project, in particular, of the multi-channel scanning polarimeter (ScanPol) designed for remote sensing studies of the global distribution of aerosol and cloud properties (such as particle size, morphology, and composition) in the terrestrial atmosphere by polarimetric and spectrophotometric measurements of the scattered sunlight in a wide range of wavelengths and viewing directions from which a scene location is observed. ScanPol is accompanied by multispectral wide-angle imager-polarimeter (MSIP) that serves to collect information on cloud conditions and Earths surface image. Various components of the polarimeter ScanPol have been prototyped, including the opto-mechanical and electronic assemblies and the scanning mirror controller. Preliminary synthetic data simulations for the retrieval of aerosol parameters over land surfaces have been performed using the Generalized Retrieval of Aerosol and Surface Properties (GRASP) algorithm. Methods for the validation of satellite data using ground-based observations of aerosol properties are also discussed. We assume that designing, building, and launching into orbit a multi-functional high-precision scanning polarimeter and an imager-polarimeter should make a significant contribution to the study of natural and anthropogenic aerosols and their climatic and ecological effects.

  4. Characteristics of a random sample of emergency food program users in New York: II. Soup kitchens.

    PubMed Central

    Bowering, J; Clancy, K L; Poppendieck, J

    1991-01-01

    A random sample of soup kitchen clients in New York City was studied and specific comparisons made on various parameters including homelessness. Compared with the general population of low income persons, soup kitchen users were overwhelmingly male, disproportionately African-American, and more likely to live alone. The homeless (41 percent of the sample) were less likely to receive food stamps or free food, or to use food pantries. Fewer of them received Medicaid or had health insurance. Forty-seven percent had no income in contrast to 29 percent of the total sample. PMID:2053673

  5. Microbiological quality of cooked foods and drinks sold in higher educational institutions around Yala, Pattani, and Narathiwat Provinces, Southern Thailand

    NASA Astrophysics Data System (ADS)

    Dalee, Abdullah D.; Sali, Khosiya; Hayeeyusoh, Nurainee; Hayeewangoh, Zubaidah; Thadah, Amporn

    2017-08-01

    Quality of cooked foods and drinks water sold within the vicinity of higher institutions located in Yala, Pattani and Narathiwat provinces were randomly sampled and microbiologically evaluated. As to Thai National Food Safety Standard, various food menu and drinks were subjected to conventionally determining the bacterial index; Most Probable Number (MPN) of coliform and fecal coliform as well as the detection of indicator organisms; Escherichia coli, Staphylococcus aureus and Salmonella sp. As for bacterial index, results showed that curry-type likes PSU-stir-fried liver (7.5x106 CFU/g), and and the lowest was PSU-Koleh chicken Roast (1.72x103 CFU/g). The highest and lowest counts of soup-type items were observed in YPH-KaengSom soup (1.9x107 CFU/g), and PSU-Palo soup (0.4x103 CFU/g), respectively. Higher bacterial counts were also found in YPH-spicy stir-fried chicken (7.5 x 106 CFU/g), and YPH-squid salad (2.2x107 CFU/g). For drinks, bacterial count ranged 2.0 x 103 to 8.3 x 103 CFU/g, and NRU-iced grape juice having the highest bacterial count (2.0x106 CFU/g). Overall, foods not complying to the Thai National Food Safety Standard of 1 x 103 CFU/g from higher to lower were those of soup, stir-fried, salad, fried, and curry categories with as much as 4:17 (23.53%), 4:21 (19.05%), 2:11 (18.18%), 2:16 (12.5%) and 1:12 (8.33%), respectively. As for Coliform and fecal coliform, the highest (>1100 MPN/g) and the lowest (0.34 MPN/g),were not much found in all food categories with percentages of 23.53, 24.00, 13.79, 9.10, and 47.37 for curry (4:17), soup (6:15), stir-fried (4:29), fried (2:22), and salad (9:19), respectively. However, indicator organisms were not detected in almost all food samples except PSU-chicken yellowish curry, NRU-chicken TongYam soup, NRU-Long-tail tuna soup, NRU-KaengSom soup, YPE-watery soup, NRU-stir-fried liver, NRU-omelets, NRU-fried chicken, YPE-crispy fish salad, and NRU-salted eggs salad, which showed the presence of E. coli, but not Staphylococcus aureus and Salmonella sp. As for drinks, 3 out of 40 samples (7.5%) were E. coli detectable, and they were YPE-water, YPE-iced tea, and YPH-iced tea. Evaluating results of such items of foods and drinks deem academically valuable, and may effectively raise public awareness and national monitoring in future.

  6. X-ray polarimeter with a transmission multilayer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kitamoto, Shunji; Murakami, Hiroshi; Shishido, Youich

    2010-02-15

    We fabricated a novel x-ray polarimeter with a transmission multilayer and measured its performance with synchrotron radiation. A self standing multilayer with seven Mo/Si bilayers was installed with an incident angle of 45 deg. in front of a back-illuminated CCD. The multilayer can be rotated around the normal direction of the CCD keeping an incident angle of 45 deg. This polarimeter can be easily installed along the optical axis of x-ray optics. By using the CCD as a photon counting detector with a moderate energy resolution, the polarization of photons in a designed energy band can be measured along withmore » the image. At high photon energies, where the multilayer is transparent, the polarimeter can be used for imaging and spectroscopic observations. We confirmed a modulation factor of 45% with 45% and 17% transmission for P- and S-polarization, respectively.« less

  7. Characteristics of an Imaging Polarimeter for the Powell Observatory

    NASA Astrophysics Data System (ADS)

    Hall, Shannon; Henson, G.

    2010-01-01

    A dual-beam imaging polarimeter has been built for use on the 14 inch Schmidt-Cassegrain telescope at the ETSU Harry D. Powell Observatory. The polarimeter includes a rotating half-wave plate and a Wollaston prism to separate light into two orthogonal linearly polarized rays. A TEC cooled CCD camera is used to detect the modulated polarized light. We present here measurements of the polarization of polarimetric standard stars. By measuring unpolarized and polarized standard stars we are able to establish the instrumental polarization and the efficiency of the instrument. The polarimeter will initially be used as a dedicated instrument in an ongoing project to monitor the eclipsing binary star, Epsilon Aurigae. This project was funded by a partnership between the National Science Foundation (NSF AST-0552798), Research Experience for Undergraduates (REU), and the Department of Defense (DoD) ASSURE (Awards to Stimulate and Support Undergraduate Research Experiences) programs.

  8. Modeling Systematic Error Effects for a Sensitive Storage Ring EDM Polarimeter

    NASA Astrophysics Data System (ADS)

    Stephenson, Edward; Imig, Astrid

    2009-10-01

    The Storage Ring EDM Collaboration has obtained a set of measurements detailing the sensitivity of a storage ring polarimeter for deuterons to small geometrical and rate changes. Various schemes, such as the calculation of the cross ratio [1], can cancel effects due to detector acceptance differences and luminosity differences for states of opposite polarization. Such schemes fail at second-order in the errors, becoming sensitive to geometrical changes, polarization magnitude differences between opposite polarization states, and changes to the detector response with changing data rates. An expansion of the polarimeter response in a Taylor series based on small errors about the polarimeter operating point can parametrize such effects, primarily in terms of the logarithmic derivatives of the cross section and analyzing power. A comparison will be made to measurements obtained with the EDDA detector at COSY-J"ulich. [4pt] [1] G.G. Ohlsen and P.W. Keaton, Jr., NIM 109, 41 (1973).

  9. Calibration system with cryogenically-cooled loads for cosmic microwave background polarization detectors.

    PubMed

    Hasegawa, M; Tajima, O; Chinone, Y; Hazumi, M; Ishidoshiro, K; Nagai, M

    2011-05-01

    We present a novel system to calibrate millimeter-wave polarimeters for cosmic microwave background (CMB) polarization measurements. This technique is an extension of the conventional metal mirror rotation approach, however, it employs cryogenically-cooled blackbody absorbers. The primary advantage of this system is that it can generate a slightly polarized signal (∼100 mK) in the laboratory; this is at a similar level to that measured by ground-based CMB polarization experiments observing a ∼10 K sky. It is important to reproduce the observing condition in the laboratory for reliable characterization of polarimeters before deployment. In this paper, we present the design and principle of the system and demonstrate its use with a coherent-type polarimeter used for an actual CMB polarization experiment. This technique can also be applied to incoherent-type polarimeters and it is very promising for the next-generation CMB polarization experiments.

  10. Structured decomposition design of partial Mueller matrix polarimeters.

    PubMed

    Alenin, Andrey S; Scott Tyo, J

    2015-07-01

    Partial Mueller matrix polarimeters (pMMPs) are active sensing instruments that probe a scattering process with a set of polarization states and analyze the scattered light with a second set of polarization states. Unlike conventional Mueller matrix polarimeters, pMMPs do not attempt to reconstruct the entire Mueller matrix. With proper choice of generator and analyzer states, a subset of the Mueller matrix space can be reconstructed with fewer measurements than that of the full Mueller matrix polarimeter. In this paper we consider the structure of the Mueller matrix and our ability to probe it using a reduced number of measurements. We develop analysis tools that allow us to relate the particular choice of generator and analyzer polarization states to the portion of Mueller matrix space that the instrument measures, as well as develop an optimization method that is based on balancing the signal-to-noise ratio of the resulting instrument with the ability of that instrument to accurately measure a particular set of desired polarization components with as few measurements as possible. In the process, we identify 10 classes of pMMP systems, for which the space coverage is immediately known. We demonstrate the theory with a numerical example that designs partial polarimeters for the task of monitoring the damage state of a material as presented earlier by Hoover and Tyo [Appl. Opt.46, 8364 (2007)10.1364/AO.46.008364APOPAI1559-128X]. We show that we can reduce the polarimeter to making eight measurements while still covering the Mueller matrix subspace spanned by the objects.

  11. Teaching Science. The Soup-Can Olympics.

    ERIC Educational Resources Information Center

    Leyden, Michael

    1996-01-01

    Presents classroom science activities to illustrate concepts of inertia, linear momentum, and friction. Students or teachers conduct races down a slope, using cans containing soups varying in mass, mass distribution, and viscosity. Students predict outcomes, compare speeds, and identify variables affecting the results. (KDFB)

  12. Aconitum Alkaloid Poisoning Related to the Culinary Uses of Aconite Roots

    PubMed Central

    Chan, Thomas Y. K.

    2014-01-01

    Aconite roots (roots or root tubers of the Aconitum species) are eaten as root vegetables and used to prepare herbal soups and meals, mainly for their purported health benefits. Aconite roots contain aconitine and other Aconitum alkaloids, which are well known cardiotoxins and neurotoxins. To better understand why Aconitum alkaloid poisoning related to the culinary uses of aconite roots can occur and characterize the risks posed by these “food supplements”, relevant published reports were reviewed. From 1995 to 2013, there were eight reports of aconite poisoning after consumption of these herbal soups and meals, including two reports of large clusters of cases (n = 19–45) and two reports of cases (n = 15–156) managed by two hospitals over a period of 4.5 to 5 years. The herbal formulae used did not adhere to the suggested guidelines, with regarding to the doses (50–500 g instead of 3–30 g per person) and types (raw instead of processed) of aconite roots used. The quantities of Aconitum alkaloids involved were huge, taking into consideration the doses of aconite roots used to prepare herbal soups/meals and the amounts of aconite roots and herbal soups/meals consumed. In a large cluster of cases, despite simmering raw “caowu” (the root tuber of A. kusnezoffii) in pork broth for 24 h, all 19 family members who consumed this soup and boiled “caowu” developed poisoning. Severe or even fatal aconite poisoning can occur after consumption of herbal soups and foods prepared from aconite roots. Even prolonged boiling may not be protective if raw preparations and large quantities of aconite roots are used. The public should be warned of the risk of severe poisoning related to the culinary and traditional medicinal uses of aconite roots. PMID:25184557

  13. Aconitum alkaloid poisoning related to the culinary uses of aconite roots.

    PubMed

    Chan, Thomas Y K

    2014-09-02

    Aconite roots (roots or root tubers of the Aconitum species) are eaten as root vegetables and used to prepare herbal soups and meals, mainly for their purported health benefits. Aconite roots contain aconitine and other Aconitum alkaloids, which are well known cardiotoxins and neurotoxins. To better understand why Aconitum alkaloid poisoning related to the culinary uses of aconite roots can occur and characterize the risks posed by these "food supplements", relevant published reports were reviewed. From 1995 to 2013, there were eight reports of aconite poisoning after consumption of these herbal soups and meals, including two reports of large clusters of cases (n = 19-45) and two reports of cases (n = 15-156) managed by two hospitals over a period of 4.5 to 5 years. The herbal formulae used did not adhere to the suggested guidelines, with regarding to the doses (50-500 g instead of 3-30 g per person) and types (raw instead of processed) of aconite roots used. The quantities of Aconitum alkaloids involved were huge, taking into consideration the doses of aconite roots used to prepare herbal soups/meals and the amounts of aconite roots and herbal soups/meals consumed. In a large cluster of cases, despite simmering raw "caowu" (the root tuber of A. kusnezoffii) in pork broth for 24 h, all 19 family members who consumed this soup and boiled "caowu" developed poisoning. Severe or even fatal aconite poisoning can occur after consumption of herbal soups and foods prepared from aconite roots. Even prolonged boiling may not be protective if raw preparations and large quantities of aconite roots are used. The public should be warned of the risk of severe poisoning related to the culinary and traditional medicinal uses of aconite roots.

  14. Vegetable Soup Activities.

    ERIC Educational Resources Information Center

    Shepard, Mary; Shepard, Ray

    Vegetable Soup is a new children's television series whose purpose is to counter the negative and destructive effects of racial isolation. This manual gives detailed instructions for discussion of activities that are presented during the television series such as: crafts, games, recipes, language activities, and children's questions. A list of…

  15. [Determination method of polysorbates in powdered soup by HPLC].

    PubMed

    Takeda, Y; Abe, Y; Ishiwata, H; Yamada, T

    2001-04-01

    A method for qualitative and quantitative analyses of polysorbates in powdered soup by HPLC was studied. Polysorbates in samples were extracted with acetonitrile after rinsing with n-hexane to remove fats and oils. The extract was cleaned up using a Bond Elut silica gel cartridge (500 mg). The cartridge was washed with ethyl acetate and polysorbates were eluted with a small amount of acetonitrile-methanol (1:2) mixture. The eluate was treated with cobalt thiocyanate solution to form a blue complex with polysorbate. In order to determine polysorbate, the complex was subjected to HPLC with a GPC column, using a mixture of acetonitrile-water (95:5) as a mobile phase, with a detection wavelength of 620 nm. The recoveries of polysorbate 80 added to powdered soups were more than 75% and the determination limit was 0.04 mg/g. When the proposed method was applied to the determination of polysorbates in 16 commercial samples of powdered soup for instant noodles and seasoning consomme, no polysorbates were detected in any sample.

  16. Comparison of non-volatile umami components in chicken soup and chicken enzymatic hydrolysate.

    PubMed

    Kong, Yan; Yang, Xiao; Ding, Qi; Zhang, Yu-Yu; Sun, Bao-Guo; Chen, Hai-Tao; Sun, Ying

    2017-12-01

    Umami taste is an important part to the taste of chicken. To isolate and identify non-volatile umami compounds, fractions from chicken soup and hydrolysate were prepared and analyzed. Amino acids were analyzed by amino acid analyzer. Organic acids and nucleotides were determined by ultra-performance liquid chromatography. Separation procedures utilizing ultrafiltration, Sephadex G-15 and reversed-phase high-performance liquid chromatography were used to isolate umami taste peptides. Combined with sensory evaluation and LC-Q-TOF-MS, the amino acid sequences of 12 oligopeptides were determined. The amount of taste compounds was higher in chicken enzymatic hydrolysate than that of chicken soup. Eight oligopeptides from chicken enzymatic hydrolysate were identified, including Ala-Asp, Ala-Met, His-Ser, Val-Glu, Ala-Glu, Asp-Ala-Gly, Glu-Asp and Ala-Glu-Ala. Four oligopeptides from chicken soup were identified, including Val-Thr, Ala-His, Ala-Phe and Thr-Glu. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Identification of the flavonoids in mungbean (Phaseolus radiatus L.) soup and their antioxidant activities.

    PubMed

    Li, He; Cao, Dongdong; Yi, Jianyong; Cao, Jiankang; Jiang, Weibo

    2012-12-15

    Mung bean soup (MBS) has been traditionally taken as a kind of health food in China. To learn the mechanisms underlying its health benefits, antioxidant capacities of the soup prepared with three cultivars of mung bean were measured. The highest DPPH radical scavenging or ferric reducing activity was observed in soup of mung bean cv. Huang. The MBS of cv. Huang and Mao exhibited higher ABTS(+) reducing activities than MBS of cv. Ming. The two major flavonoids in the MBS were purified and identified as vitexin and isovitexin, respectively. Modeling samples containing vitexin and isovitexin at the same levels as them in the MBS were prepared to assess their antioxidant contributions in the MBS. Our results showed that antioxidant capacities of the MBS mainly derived from vitexin and isovitexin, these flavonoids accounted for the most of total DPPH radicals scavenging, ferric reducing and ABTS(+) reducing scavenging activities in MBS of all the three cultivars. Copyright © 2012 Elsevier Ltd. All rights reserved.

  18. Effect of guar gum on hunger and satiety after meals of differing fat content: relationship with gastric emptying.

    PubMed

    French, S J; Read, N W

    1994-01-01

    To determine whether the satiating effects of fiber are due to delaying gastric emptying or slowing absorption of meals, 3% guar gum was added to high- and low-fat soups and gastric emptying rate, hunger, and satiety were measured in eight male volunteers. Guar gum delayed the emptying of the low-fat soup but the small delays in the return of hunger and decline of fullness were significantly correlated with the gastric emptying, suggesting mediation by gastric mechanoreceptors. The high-fat soup also emptied more slowly but this had no effect on the return of hunger or the decline in fullness. The delays in the return of hunger and decline of fullness were far greater when guar gum was added to the fatty soup; these delays were not correlated with the small additional delay in gastric emptying. This is more compatible with slowed absorption and prolonged contact of nutrients with intestinal chemoreceptors.

  19. Rapid spectro-polarimetry to probe molecular symmetry in multiplex coherent anti-Stokes Raman scattering.

    PubMed

    Würthwein, Thomas; Brinkmann, Maximilian; Hellwig, Tim; Fallnich, Carsten

    2017-11-21

    We present the simultaneous detection of the spectrum and the complete polarization state of a multiplex coherent anti-Stokes Raman scattering signal with a fast division-of-amplitude spectro-polarimeter. The spectro-polarimeter is based on a commercial imaging spectrograph, a birefringent wedge prism, and a segmented polarizer. Compared to the standard rotating-retarder fixed-analyzer spectro-polarimeter, only a single measurement is required and an up to 21-fold reduced acquisition time is shown. The measured Stokes parameters allow us to differentiate between vibrational symmetries and to determine the depolarization ratio ρ by data post-processing.

  20. Development and application of an emitter for research of an on-board ultraviolet polarimeter

    NASA Astrophysics Data System (ADS)

    Nevodovskyi, P. V.; Geraimchuk, M. D.; Vidmachenko, A. P.; Ivakhiv, O. V.

    2018-05-01

    In carrying out of the work a layout of on-board small-sized ultraviolet polarimeter (UVP) was created. UVP is the device, which provides an implementation of passive remote studies of stratospheric aerosol from the board of the microsatellite of the Earth by the method of polarimetry. For carrying out of tests and the research of polarimetric equipment, a special stand was created at MAO of NAS of Ukraine. In its composition is an ultraviolet emitter. Emitter is one of the main components of a special stand for the study of on-board ultraviolet polarimeters.

  1. The Atacama B-mode Search: Status and Prospect

    NASA Astrophysics Data System (ADS)

    Kusaka, Akito

    2013-04-01

    The Atacama B-mode Search (ABS) experiment is a 145 GHz polarimeter designed to measure the B-mode polarization of the Cosmic Microwave Background (CMB) at degre angular scales. In January 2012, ABS has deployed 240 polarimeters employing transition-edge sensor (TES) bolometers. ABS has unique advantages for the measurement of B modes. This includes a continuously rotating half-wave plate that provides fast and clean modulation, as well as systematically clean optics that consist of a cryogenic side-fed Dragone telescope and feedhorn coupled TES polarimeters. In this talk, we will present the status and prospect of ABS.

  2. SOLPOL: A Solar Polarimeter for Hard X-Rays and Gamma-Rays

    NASA Technical Reports Server (NTRS)

    McConnell, Michael L.

    1999-01-01

    Th goal of this project was to continue the development of a hard X-ray polarimeter for studying solar flares. In earlier work (funded by a previous SR&T grant), we had already achieved several goals, including the following: 1) development of a means of producing a polarized radiation source in the lab that could be used for prototype development; 2) demonstrated the basic Compton scatter polarimeter concept using a simple laboratory setup; 3) used the laboratory results to verify our Monte Carlo simulations; and 4) investigated various detector technologies that could be incorporated into the polarimeter design. For the current one-year program, we wanted to fabricate and test a laboratory science model based on our SOLPOL (Solar Polarimeter) design. The long-term goal of this effort is to develop and test a prototype design that could be used to study flare emissions from either a balloon- or space-borne platform. The current program has achieved its goal of fabricating and testing a science model of the SOLPOL design, although additional testing of the design (and detailed comparison with Monte Carlo simulations) is still desired. This one-year program was extended by six months (no-cost extension) to cover the summer of 1999, when undergraduate student support was available to complete some of the laboratory testing.

  3. Chemical Distances for Percolation of Planar Gaussian Free Fields and Critical Random Walk Loop Soups

    NASA Astrophysics Data System (ADS)

    Ding, Jian; Li, Li

    2018-05-01

    We initiate the study on chemical distances of percolation clusters for level sets of two-dimensional discrete Gaussian free fields as well as loop clusters generated by two-dimensional random walk loop soups. One of our results states that the chemical distance between two macroscopic annuli away from the boundary for the random walk loop soup at the critical intensity is of dimension 1 with positive probability. Our proof method is based on an interesting combination of a theorem of Makarov, isomorphism theory, and an entropic repulsion estimate for Gaussian free fields in the presence of a hard wall.

  4. Chemical Distances for Percolation of Planar Gaussian Free Fields and Critical Random Walk Loop Soups

    NASA Astrophysics Data System (ADS)

    Ding, Jian; Li, Li

    2018-06-01

    We initiate the study on chemical distances of percolation clusters for level sets of two-dimensional discrete Gaussian free fields as well as loop clusters generated by two-dimensional random walk loop soups. One of our results states that the chemical distance between two macroscopic annuli away from the boundary for the random walk loop soup at the critical intensity is of dimension 1 with positive probability. Our proof method is based on an interesting combination of a theorem of Makarov, isomorphism theory, and an entropic repulsion estimate for Gaussian free fields in the presence of a hard wall.

  5. Vegetables, Soups, Sauces, Gravies and Beverages.

    ERIC Educational Resources Information Center

    Marine Corps Inst., Washington, DC.

    Developed as part of the Marine Corps Institute (MCI) correspondence training program, this course on vegetables, soups, sauces, gravies, and beverages is designed to increase Marine Corps cooks' effectiveness as food handlers, using the proper techniques in the preparation of these items. Introductory materials include specific information for…

  6. Atherogenic potentials of some Nigerian meals.

    PubMed

    Eyong, E U; Umoh, I B; Ogu, T I; Edet, E E; Eteng, M U; Igiri, A O

    2007-01-01

    The atherogenic potentials of peeled grated cocoyam (Xanthosoma maffafa scot) "ekpang nkukwo", pounded yam (Discorea spp) with plain soup "afia efere", and plantain porridge (Musa paradisiaca) "iwuk ukom" meals were investigated. The three meals were fed to three different groups of albino rats of Wistar strain for a period of twenty eight days. A fourth group which served as control was feed with normal rat pellet. The mean total plasma cholesterol level in the pounded yam with plain soup fed group was significantly lower [P < 0.05] when compared to the control and peeled grated cocoyam fed groups. The mean total plasma triglyceride (MTPTG) level in the pounded yam with plain soup fed group was significantly lower [P < 0.05] when compared to the control group. However the MTPTG level in the peeled grated cocoyam and plantain porridge fed groups were comparable to control. The mean HDL-cholesterol level in the peeled grated cocoyam and plantain fed groups were comparable control. The mean LDL-cholesterol level in the peeled grated cocoyam and plantain porridge fed groups was significantly lower [P < 0.05] than the control group. The LDL-cholesterol and VLDL-cholesterol in the pounded yam with plain soup fed group was significantly lower [P < 0.05] when compared to control. These findings suggest low atherogenic potentials of the pounded yam with plain soup meal compared to the peeled grated cocoyam and plantain porridge meals.

  7. Vegetable Soup: Parent-Teacher Guide.

    ERIC Educational Resources Information Center

    New York State Education Dept. , Albany. Bureau of Mass Communications.

    The goal of Vegetable Soup, a television series for children, is to help counter the negative, destructive effects of racial prejudice and racial isolation and to reinforce and dramatize the positive, life enhancing value of human diversity in entertaining and affective presentations that children can understand and relate to. This teaching guide…

  8. Quick, easy to prepare freeze-dried soups

    NASA Technical Reports Server (NTRS)

    Ramirez, R. V.; Larson, R. W.

    1972-01-01

    Major advantages of soups are that they totally rehydrate in less than five minutes in water at approximately 150 deg F, maintain flavor and quality stability for two weeks in a 100 F environment, and remain stable for considerably longer at ambient temperatures. They are suitable for either household or field use.

  9. Precision Electron Beam Polarimetry in Hall C at Jefferson Lab

    NASA Astrophysics Data System (ADS)

    Gaskell, David

    2013-10-01

    The electron beam polarization in experimental Hall C at Jefferson Lab is measured using two devices. The Hall-C/Basel Møller polarimeter measures the beam polarization via electron-electron scattering and utilizes a novel target system in which a pure iron foil is driven to magnetic saturation (out of plane) using a superconducting solenoid. A Compton polarimeter measures the polarization via electron-photon scattering, where the photons are provided by a high-power, CW laser coupled to a low gain Fabry-Perot cavity. In this case, both the Compton-scattered electrons and backscattered photons provide measurements of the beam polarization. Results from both polarimeters, acquired during the Q-Weak experiment in Hall C, will be presented. In particular, the results of a test in which the Møller and Compton polarimeters made interleaving measurements at identical beam currents will be shown. In addition, plans for operation of both devices after completion of the Jefferson Lab 12 GeV Upgrade will also be discussed.

  10. Digital Correlation Microwave Polarimetry: Analysis and Demonstration

    NASA Technical Reports Server (NTRS)

    Piepmeier, J. R.; Gasiewski, A. J.; Krebs, Carolyn A. (Technical Monitor)

    2000-01-01

    The design, analysis, and demonstration of a digital-correlation microwave polarimeter for use in earth remote sensing is presented. We begin with an analysis of three-level digital correlation and develop the correlator transfer function and radiometric sensitivity. A fifth-order polynomial regression is derived for inverting the digital correlation coefficient into the analog statistic. In addition, the effects of quantizer threshold asymmetry and hysteresis are discussed. A two-look unpolarized calibration scheme is developed for identifying correlation offsets. The developed theory and calibration method are verified using a 10.7 GHz and a 37.0 GHz polarimeter. The polarimeters are based upon 1-GS/s three-level digital correlators and measure the first three Stokes parameters. Through experiment, the radiometric sensitivity is shown to approach the theoretical as derived earlier in the paper and the two-look unpolarized calibration method is successfully compared with results using a polarimetric scheme. Finally, sample data from an aircraft experiment demonstrates that the polarimeter is highly-useful for ocean wind-vector measurement.

  11. POET: a SMEX mission for gamma ray burst polarimetry

    NASA Astrophysics Data System (ADS)

    McConnell, Mark L.; Baring, Matthew; Bloser, Peter; Dwyer, Joseph F.; Emslie, A. Gordon; Ertley, Camden D.; Greiner, Jochen; Harding, Alice K.; Hartmann, Dieter H.; Hill, Joanne E.; Kaaret, Philip; Kippen, R. M.; Mattingly, David; McBreen, Sheila; Pearce, Mark; Produit, Nicolas; Ryan, James M.; Ryde, Felix; Sakamoto, Takanori; Toma, Kenji; Vestrand, W. Thomas; Zhang, Bing

    2014-07-01

    Polarimeters for Energetic Transients (POET) is a mission concept designed to t within the envelope of a NASA Small Explorer (SMEX) mission. POET will use X-ray and gamma-ray polarimetry to uncover the energy release mechanism associated with the formation of stellar-mass black holes and investigate the physics of extreme magnetic ields in the vicinity of compact objects. Two wide-FoV, non-imaging polarimeters will provide polarization measurements over the broad energy range from about 2 keV up to about 500 keV. A Compton scatter polarimeter, using an array of independent scintillation detector elements, will be used to collect data from 50 keV up to 500 keV. At low energies (2{15 keV), data will be provided by a photoelectric polarimeter based on the use of a Time Projection Chamber for photoelectron tracking. During a two-year baseline mission, POET will be able to collect data that will allow us to distinguish between three basic models for the inner jet of gamma-ray bursts.

  12. A new system model for radar polarimeters

    NASA Technical Reports Server (NTRS)

    Freeman, Anthony

    1991-01-01

    The validity of the 2 x 2 receive R and transmit T model for radar polarimeter systems, first proposed by Zebker et al. (1987), is questioned. The model is found to be invalid for many practical realizations of radar polarimeters, which can lead to significant errors in the calibration of polarimetric radar images. A more general model is put forward, which addresses the system defects which cause the 2 x 2 model to break down. By measuring one simple parameter from a polarimetric active radar calibration (PARC), it is possible to transform the scattering matrix measurements made by a radar polarimeter to a format compatible with a 2 x 2 R and T matrix model. Alternatively, the PARC can be used to verify the validity of the 2 x 2 model for any polarimetric radar system. Recommendations for the use of PARCs in polarimetric calibration and to measure the orientation angle of the horizontal (H) and vertical (V) coordinate system are also presented.

  13. A new system model for radar polarimeters

    NASA Astrophysics Data System (ADS)

    Freeman, Anthony

    1991-09-01

    The validity of the 2 x 2 receive R and transmit T model for radar polarimeter systems, first proposed by Zebker et al. (1987), is questioned. The model is found to be invalid for many practical realizations of radar polarimeters, which can lead to significant errors in the calibration of polarimetric radar images. A more general model is put forward, which addresses the system defects which cause the 2 x 2 model to break down. By measuring one simple parameter from a polarimetric active radar calibration (PARC), it is possible to transform the scattering matrix measurements made by a radar polarimeter to a format compatible with a 2 x 2 R and T matrix model. Alternatively, the PARC can be used to verify the validity of the 2 x 2 model for any polarimetric radar system. Recommendations for the use of PARCs in polarimetric calibration and to measure the orientation angle of the horizontal (H) and vertical (V) coordinate system are also presented.

  14. Determination of electron beam polarization using electron detector in Compton polarimeter with less than 1% statistical and systematic uncertainty

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Narayan, Amrendra

    2015-05-01

    The Q-weak experiment aims to measure the weak charge of proton with a precision of 4.2%. The proposed precision on weak charge required a 2.5% measurement of the parity violating asymmetry in elastic electron - proton scattering. Polarimetry was the largest experimental contribution to this uncertainty and a new Compton polarimeter was installed in Hall C at Jefferson Lab to make the goal achievable. In this polarimeter the electron beam collides with green laser light in a low gain Fabry-Perot Cavity; the scattered electrons are detected in 4 planes of a novel diamond micro strip detector while the back scatteredmore » photons are detected in lead tungstate crystals. This diamond micro-strip detector is the first such device to be used as a tracking detector in a nuclear and particle physics experiment. The diamond detectors are read out using custom built electronic modules that include a preamplifier, a pulse shaping amplifier and a discriminator for each detector micro-strip. We use field programmable gate array based general purpose logic modules for event selection and histogramming. Extensive Monte Carlo simulations and data acquisition simulations were performed to estimate the systematic uncertainties. Additionally, the Moller and Compton polarimeters were cross calibrated at low electron beam currents using a series of interleaved measurements. In this dissertation, we describe all the subsystems of the Compton polarimeter with emphasis on the electron detector. We focus on the FPGA based data acquisition system built by the author and the data analysis methods implemented by the author. The simulations of the data acquisition and the polarimeter that helped rigorously establish the systematic uncertainties of the polarimeter are also elaborated, resulting in the first sub 1% measurement of low energy (?1 GeV) electron beam polarization with a Compton electron detector. We have demonstrated that diamond based micro-strip detectors can be used for tracking in a high radiation environment and it has enabled us to achieve the desired precision in the measurement of the electron beam polarization which in turn has allowed the most precise determination of the weak charge of the proton.« less

  15. Determination of electron beam polarization using electron detector in Compton polarimeter with less than 1% statistical and systematic uncertainty

    NASA Astrophysics Data System (ADS)

    Narayan, Amrendra

    The Q-weak experiment aims to measure the weak charge of proton with a precision of 4.2%. The proposed precision on weak charge required a 2.5% measurement of the parity violating asymmetry in elastic electron - proton scattering. Polarimetry was the largest experimental contribution to this uncertainty and a new Compton polarimeter was installed in Hall C at Jefferson Lab to make the goal achievable. In this polarimeter the electron beam collides with green laser light in a low gain Fabry-Perot Cavity; the scattered electrons are detected in 4 planes of a novel diamond micro strip detector while the back scattered photons are detected in lead tungstate crystals. This diamond micro-strip detector is the first such device to be used as a tracking detector in a nuclear and particle physics experiment. The diamond detectors are read out using custom built electronic modules that include a preamplifier, a pulse shaping amplifier and a discriminator for each detector micro-strip. We use field programmable gate array based general purpose logic modules for event selection and histogramming. Extensive Monte Carlo simulations and data acquisition simulations were performed to estimate the systematic uncertainties. Additionally, the Moller and Compton polarimeters were cross calibrated at low electron beam currents using a series of interleaved measurements. In this dissertation, we describe all the subsystems of the Compton polarimeter with emphasis on the electron detector. We focus on the FPGA based data acquisition system built by the author and the data analysis methods implemented by the author. The simulations of the data acquisition and the polarimeter that helped rigorously establish the systematic uncertainties of the polarimeter are also elaborated, resulting in the first sub 1% measurement of low energy (~1GeV) electron beam polarization with a Compton electron detector. We have demonstrated that diamond based micro-strip detectors can be used for tracking in a high radiation environment and it has enabled us to achieve the desired precision in the measurement of the electron beam polarization which in turn has allowed the most precise determination of the weak charge of the proton.

  16. Calibration method of microgrid polarimeters with image interpolation.

    PubMed

    Chen, Zhenyue; Wang, Xia; Liang, Rongguang

    2015-02-10

    Microgrid polarimeters have large advantages over conventional polarimeters because of the snapshot nature and because they have no moving parts. However, they also suffer from several error sources, such as fixed pattern noise (FPN), photon response nonuniformity (PRNU), pixel cross talk, and instantaneous field-of-view (IFOV) error. A characterization method is proposed to improve the measurement accuracy in visible waveband. We first calibrate the camera with uniform illumination so that the response of the sensor is uniform over the entire field of view without IFOV error. Then a spline interpolation method is implemented to minimize IFOV error. Experimental results show the proposed method can effectively minimize the FPN and PRNU.

  17. High-precision polarimetry at the Mont-Mégantic Observatory with the new polarimeter POMM

    NASA Astrophysics Data System (ADS)

    Bastien, Pierre; Hernandez, Olivier; Albert, Loïc.; Artigau, Étienne; Doyon, René; Drissen, Laurent; Lafrenière, David; Moffat, Antony F. J.; St-Louis, Nicole

    2014-07-01

    A new polarimeter has been built for the "Observatoire du Mont-Mégantic" (POMM) and is now in commissioning phase. It will allow polarization measurements with a precision of 10-6, an improvement by a factor of 100 over the previous observatory polarimeter. The characteristics of the instrument that allow this goal are briefly discussed and the planned science observations are presented. They include exoplanets near their host star (hot Jupiters), transiting exoplanets, stars with debris disks, young stars with proto-planetary disks, brown dwarfs, massive Wolf-Rayet stars and comets. The details of the optical and mechanical designs are presented in two other papers.

  18. Role of intensive and extensive variables in a soup of firms in economy to address long run prices and aggregate data

    NASA Astrophysics Data System (ADS)

    Hosseiny, Ali; Gallegati, Mauro

    2017-03-01

    We review the production function and the hypothesis of equilibrium in the neoclassical framework. We notify that in a soup of sectors in economy, while capital and labor resemble extensive variables, wage and rate of return on capital act as intensive variables. As a result, Baumol and Bowen's statement of equal wages is inevitable from the thermodynamics point of view. We try to see how aggregation can be performed concerning the extensive variables in a soup of firms. We provide a toy model to perform aggregation for production and the labor income as extensive quantities in a neoclassical framework.

  19. Self-Calibration of CMB Polarimeters

    NASA Astrophysics Data System (ADS)

    Keating, Brian

    2013-01-01

    Precision measurements of the polarization of the cosmic microwave background (CMB) radiation, especially experiments seeking to detect the odd-parity "B-modes", have far-reaching implications for cosmology. To detect the B-modes generated during inflation the flux response and polarization angle of these experiments must be calibrated to exquisite precision. While suitable flux calibration sources abound, polarization angle calibrators are deficient in many respects. Man-made polarized sources are often not located in the antenna's far-field, have spectral properties that are radically different from the CMB's, are cumbersome to implement and may be inherently unstable over the (long) duration these searches require to detect the faint signature of the inflationary epoch. Astrophysical sources suffer from time, frequency and spatial variability, are not visible from all CMB observatories, and none are understood with sufficient accuracy to calibrate future CMB polarimeters seeking to probe inflationary energy scales of ~1000 TeV. CMB TB and EB modes, expected to identically vanish in the standard cosmological model, can be used to calibrate CMB polarimeters. By enforcing the observed EB and TB power spectra to be consistent with zero, CMB polarimeters can be calibrated to levels not possible with man-made or astrophysical sources. All of this can be accomplished without any loss of observing time using a calibration source which is spectrally identical to the CMB B-modes. The calibration procedure outlined here can be used for any CMB polarimeter.

  20. "Snow Soup" Students Take on Animation Creation

    ERIC Educational Resources Information Center

    Nikirk, Martin

    2009-01-01

    This article describes the process of producing "Snow Soup"--the 2009 Adobe Flash animation produced by the Computer Game Development and Animation seniors of Washington County Technical High School in Hagerstown, Maryland, for libraries in their area. In addition to the Flash product, the students produced two related Game Maker games, a printed…

  1. General Framework for Evaluating Password Complexity and Strength

    DTIC Science & Technology

    2015-11-15

    stronger password requirements: User attitudes and behaviors,” in Pro- ceedings of the Sixth Symposium on Usable Privacy and Security, ser. SOUPS ’10. New...Proceedings of the Eighth Symposium on Usable Privacy and Security, ser. SOUPS ’12. New York, NY, USA: ACM, 2012, pp. 1–20. [22] P. Kelley, S. Komanduri

  2. Re-Inventing Counterinsurgency Doctrine: Why The United States Failed in Iraq and Afghanistan

    DTIC Science & Technology

    2016-02-16

    5 Dr Richard Stubbs, 113-118. 6 John A. Nagl, Learning to Eat Soup With a Knife: Counterinsurgency Lessons From Malaya and Vietnam...Modern War in Theory and Practice. New York: The Penguin Press, 2014. Nagl, John A. Learning to Eat Soup With a Knife: Counterinsurgency Lessons From

  3. Re-Inventing Counterinsurgency Doctrine: Why the United States Failed in Iraq and Afghanistan

    DTIC Science & Technology

    2016-01-08

    5 Dr Richard Stubbs, 113-118. 6 John A. Nagl, Learning to Eat Soup With a Knife: Counterinsurgency Lessons From Malaya and Vietnam...Modern War in Theory and Practice. New York: The Penguin Press, 2014. Nagl, John A. Learning to Eat Soup With a Knife: Counterinsurgency Lessons From

  4. Stone Soup: Photo-Elicitation as a Learning Tool in the Food Geography Classroom

    ERIC Educational Resources Information Center

    Kurtz, Hilda E.; Wood, Jason

    2014-01-01

    This paper showcases self-reflective and inclusive pedagogy using photo-elicitation in a food geography course assignment. The Stone Soup project positions students as both researchers and participant-subjects in a participant-driven photo-elicitation (PDPE) study of students' foodways. Student papers for this assignment demonstrate rich…

  5. Chicken Soup for the Portfolio.

    ERIC Educational Resources Information Center

    Dwyer, Edward J.

    The popular "Chicken Soup for the Soul" series of books demonstrates the tremendous desire of people in all walks of life to tell their stories. A professor of reading/language arts methods for students in a program leading to teacher certification reads to his classes every day from a wide variety of materials, including stories from…

  6. Public Opinion Polls, Chicken Soup and Sample Size

    ERIC Educational Resources Information Center

    Nguyen, Phung

    2005-01-01

    Cooking and tasting chicken soup in three different pots of very different size serves to demonstrate that it is the absolute sample size that matters the most in determining the accuracy of the findings of the poll, not the relative sample size, i.e. the size of the sample in relation to its population.

  7. Effect of Micronutrient Powder Addition on Sensory Properties of Foods for Older Adults.

    PubMed

    Field, Katherine M; Duncan, Alison M; Keller, Heather H; Stark, Ken D; Duizer, Lisa M

    2017-10-01

    Micronutrient fortification can improve nutrient intake of older adults in long-term care. However, previous studies indicate that micronutrient fortification can alter food sensory attributes and, potentially, consumer liking. Others have found no effect of fortification on liking. This research investigates the effect of micronutrient powder addition on the sensory properties of selected foods commonly served in long-term care. A micronutrient powder containing 9 vitamins and 3 minerals was added to tomato soup and oatmeal at different levels. Using projective mapping, changes in sensory properties were observed with powder addition. Descriptive analysis, used to quantify these changes, showed that both the tomato soup and oatmeal had reduced flavor as the amount of added micronutrient powder increased. Oatmeal also showed changes in texture with fortification. Consumer liking scores for tomato soup showed that micronutrient addition affected liking when 100% of a daily dose was added into the soup. Addition of 50% of the daily dose did not affect liking. Oatmeal liking did not differ between fortified and unfortified samples. Results from this research can be used to decide whether a micronutrient powder of selected vitamins and minerals can be added to foods served to older adults in long-term care. Although sensory properties of the foods will be altered, fortification of both tomato soup and oatmeal with the developed powder is possible without reducing consumer liking to the point where it is disliked. © 2017 Institute of Food Technologists®.

  8. Atmosphere aerosol satellite project Aerosol-UA

    NASA Astrophysics Data System (ADS)

    Milinevsky, Gennadi; Yatskiv, Yaroslav; Syniavskyi, Ivan; Bovchaliuk, Andrii; Degtyaryov, Oleksandr; Sosonkin, Mikhail; Mishchenko, Michael; Danylevsky, Vassyl; Ivanov, Yury; Oberemok, Yevgeny; Masley, Volodymyr; Rosenbush, Vera; Moskalev, Sergii

    2017-04-01

    The experiment Aerosol-UA is Ukrainian space mission aimed to the terrestrial atmospheric aerosol spatial distribution and microphysics investigations. The experiment concept is based on idea of Glory/APS mission of precise orbital measurements of polarization and intensity of the sunlight scattered by the atmosphere, aerosol and the surface the multichannel Scanning Polarimeter (ScanPol) with narrow field-of-view. ScanPol measurements will be accompanied by the wide-angle MultiSpectral Imager-Polarimeter (MSIP). The ScanPol is designed to measure Stokes parameters I, Q, U within the spectral range from the UV to the SWIR in a wide range of phase angles along satellite ground path. Expected ScanPol polarimetric accuracy is 0.15%. A high accuracy measurement of the degree of linear polarization is provided by on-board calibration of the ScanPol polarimeter. On-board calibration is performed for each scan of the mirror scanning system. A set of calibrators is viewed during the part of the scan range when the ScanPol polarimeter looks in the direction opposite to the Earth's surface. These reference assemblies provide calibration of the zero of the polarimetric scale (unpolarized reference assembly) and the scale factor for the polarimetric scale (polarized reference assembly). The zero of the radiometric scale is provided by the dark reference assembly.The spectral channels of the ScanPol are used to estimate the tropospheric aerosol absorption, the aerosol over the ocean and the land surface, the signals from cirrus clouds, stratospheric aerosols caused by major volcanic eruptions, and the contribution of the Earth's surface. The imager-polarimeter MSIP will collect 60°x60° field-of-view images on the state of the atmosphere and surface in the area, where the ScanPol polarimeter will measure, to retrieve aerosol optical depth and polarization properties of aerosol by registration of three Stokes parameters simultaneously in three spectral channels. The two more channels of the MSIP are the intensity channels that serve to obtain images in eight spectral wavebands to retrieve the aerosol optical depth. The main feature of the each MSIP channel is the splitting of the image by a special prism-splitter to four images on the same CCD detector. In that way we can simultaneously measure four polarization components at 0°, 45°, 90° and 135° as images in each of three polarization channels. One of the special features of ScanPol/MSIP concept is calibration of the MSIP using ScanPol data in the same field-of-view with 1% expected polarization accuracy. The Aerosol-UA experiment is planned to be launched in 2020 at the new satellite platform YuzhSat developed in the Yuzhnoye Design Office. The GRASP algorithm (Dubovik et al. 2014, doi: 10.1117/2.1201408.005558) is planned for Aerosol-UA data processing and AERONET sun photometers observations for validation. Acknowledgements. The work was partly supported by the Special Complex Program for Space Research 2012-2016 of the National Academy of Sciences of Ukraine, by the project 16BF051-02 of the Taras Shevchenko National University of Kyiv, and by the grant of the State Fund for Fundamental Research, project F73/115-2016.

  9. Characterization of the dynamics of surface stabilized ferroelectric liquid crystal under electric field by full optical snapshot matrix Mueller polarimeter

    NASA Astrophysics Data System (ADS)

    Silva, Vinicius N. H.; Babilotte, Philippe; Rivet, Sylvain; Dubreuil, Mathieu; Le Jeune, Bernard; Dupont, Laurent

    2012-12-01

    We investigated the layer dynamics of a conventional surface-stabilized ferroelectric liquid crystal (SSFLC) using a full-optical snapshot Mueller matrix polarimeter (SMMP) based on wavelength polarization coding. Time-resolved polarimetric measurements were performed with different SSFLC samples, and a strong correlation between the polarimetric parameters and the SSFLC under electric field at different exposure times was found. It has been shown that the SMMP polarimeter is able to determine the evolution of the trajectory of the liquid crystal director between the two addressed states, the reversible motion of the smectic layer while switching, as well as the irreversible transition from chevron to bookshelf texture.

  10. A New Polarimeter at the Universite de Montreal

    NASA Astrophysics Data System (ADS)

    Manset, Nadine; Bastien, Pierre

    1995-05-01

    We present Beauty and The Beast, a new polarimeter of the Universite de Montreal, formerly built for the Canada-France-Hawaii telescope (CFHT) but never commissioned there. This computer-controlled Pockels cell polarimeter has been restored to working order and offers a wide range of possibilities: almost all functions are under remote control, linear or circular polarization observations are both possible, a filter slide provides easy access to up to six different bandpasses, and the Pockels cell and Fabry lenses are kept at a constant temperature. In addition to controlling the instrument, the software allows the use of pre-defined sequences of observation, and does data acquisition and reduction. (SECTION: Astronomical Instrumentation)

  11. Ultraviolet spectrometer and polarimeter (UVSP) catalog of observations. Volume 2: Experiments 30720-63057, April 1985 - February 1988

    NASA Technical Reports Server (NTRS)

    Henze, William, Jr.

    1993-01-01

    A catalog of observations (experiments) obtained by the Ultraviolet Spectrometer and Polarimeter (UVSP) on the Solar Maximum Mission (SMM) from Feb. 1980 to Nov. 1989 is presented. The information for each entry includes the time of each observation, the observed position of the Sun, the spacecraft roll angle, the slit used, and instrument parameters such as raster size, pixel spacing, wavelength, polarimeter usage, gate time, etc. The document is split into three volumes: Volume 1 contains experiments 1-30719 (February 1980-April 1985); Volume 2 contains experiments 30720-63057 (April 1985-February 1988); and Volume 3 contains experiments 63058-99771 (February 1988-November 1989).

  12. Ultraviolet spectrometer and polarimeter (UVSP) catalog of observations. Volume 1: Experiments 1-30719, February 1980 - April 1985

    NASA Technical Reports Server (NTRS)

    Henze, William, Jr.

    1993-01-01

    A catalog of observations (experiments) obtained by the Ultraviolet Spectrometer and Polarimeter (UVSP) on the Solar Maximum Mission (SMM) from Feb. 1980 to Nov. 1989 is presented. The information for each entry includes the time of each observation, the observed position of the Sun, the spacecraft roll angle, the slit used, and instrument parameters such as raster size, pixel spacing, wavelength, polarimeter usage, gate time, etc. The document is split into three volumes: Volume 1 contains experiments 1-30719 (February 1980-April 1985); Volume 2 contains experiments 30720-63057 (April 1985-February 1988); and Volume 3 contains experiments 63058-99771 (February l988-November 1989).

  13. A Gamma Polarimeter for Neutron Polarization Measurement in a Liquid Deuterium Target for Parity Violation in Polarized Neutron Capture on Deuterium.

    PubMed

    Komives, A; Sint, A K; Bowers, M; Snow, M

    2005-01-01

    A measurement of the parity-violating gamma asymmetry in n-D capture would yield information on N-N parity violation independent of the n-p system. Since cold neutrons will depolarize in a liquid deuterium target in which the scattering cross section is much larger than the absorption cross section, it will be necessary to quantify the loss of polarization before capture. One way to do this is to use the large circular polarization of the gamma from n-D capture and analyze the circular polarization of the gamma in a gamma polarimeter. We describe the design of this polarimeter.

  14. First Light for Mimir, a Near-Infrared Wide-Field Imager, Spectrometer, and Polarimeter for the Perkins Telescope

    NASA Astrophysics Data System (ADS)

    Clemens, D. P.; Sarcia, D.; Tollestrup, E. V.; Grabau, A.; Bosh, A.; Buie, M.; Taylor, B.; Dunham, E.

    2004-12-01

    The Mimir instrument completed its 5-year development in our Boston University lab and was delivered this past July to Flagstaff, Arizona and the Perkins telescope for commissioning. Mimir is a "facility-class" multi-function near-infrared imager, spectrometer, and polarimeter developed under a joint program by Boston University and Lowell Observatory scientists, staff, and engineers. It fully covers the wavelength range 1-5 microns onto its 1024x1024 Aladdin III InSb array detector. In its wide-field imaging mode, a 10x10 arcmin field is sampled at 0.6 arcsec per pixel. In its narrow-field mode, the field is 3x3 arcmin, sampled at 0.2 arcsec per pixel. A full complement of JHKsL'M' broad-band filters are present in its four filter wheels. Spectroscopy is accomplished using a matched slit-plate and selector system, three grisms, and special spectroscopy filters (for order suppression). Polarimetry is accomplished using rotating half-wave plates and a fixed wire grid. All of these modes were certified in the lab; all have been certified at the Perkins telescope during the August/September commissioning run. Mode switches are accomplished in a matter of only seconds, making Mimir exceedingly versatile. The poster highlights the designs and components of Mimir as well as examples of images, spectra, and polarimetry from the commissioning telescope runs this past fall. Internal, shared-risk observations with Mimir begin this quarter. Mimir design and development has been funded by NASA, NSF, and the W.M. Keck Foundation.

  15. STS-67 crew insignia

    NASA Technical Reports Server (NTRS)

    1995-01-01

    Observation and remote exploration of the Universe in the ultraviolet wavelengths of light are the focus of the STS-67/ASTRO-2 mission, as depicted in the crew patch designed by the crew members. The insignia shows the ASTRO-2 telescopes in the Space Shuttle Endeavour's payload bay, orbiting high above Earth's atmosphere. The three sets of rays, diverging from the telescope on the patch atop the Instrument Pointing System (IPS), correspond to the three ASTRO-2 telescopes - the Hopkins Ultraviolet Telescope (HUT), The Ultraviolet Imaging Telescope (UIT), and the Wisconsin Ultraviolet Photo-Polarimeter Experiment (WUPPE). The telescopes are coaligned to simultaneously view the same astronomical object, as shown by the convergence of rays on the NASA symbol. This symbol also represents the excellence of the union of the NASA teams and the universality's in the exploration of the universe through astronomy. The celestial targets of ASTRO-2 include the observation of planets, stars and gala

  16. Rewarming the Primordial Soup: Revisitations and Rediscoveries in Prebiotic Chemistry.

    PubMed

    Saladino, Raffaele; Šponer, Judit E; Šponer, Jiří; Di Mauro, Ernesto

    2018-01-04

    A short history of Campbell's primordial soup: In this essay we try to disclose some of the historical connections between the studies that have contributed to our current understanding of the emergence of catalytic RNA molecules and their components from an inanimate matter. © 2017 The Authors. Published by Wiley-VCH Verlag GmbH & Co. KGaA.

  17. Dependency on Soup Kitchens in Urban Areas of New York State.

    ERIC Educational Resources Information Center

    Rauschenbach, Barbara S.; And Others

    1990-01-01

    A study of the dependency of persons on soup kitchens in Albany, Buffalo, Rochester, Syracuse, and Westchester County (New York) identified who uses these kitchens, the extent to which they are dependent on them, what other food programs they use, what their perceived need from other services is, and dependency differences of subgroups. (JS)

  18. Shareowners' Equity at Campbell Soup: How Can Equity Be Negative?

    ERIC Educational Resources Information Center

    Mohrman, Mary Beth; Stuerke, Pamela S.

    2014-01-01

    This paper presents an instructional case based on the 2001 annual report of the Campbell Soup Company (CPB). During that year, CPB's shareowners' equity went from a surplus of USD137 million to a deficit of USD247 million. The analysis will allow students to determine that the change resulted from borrowing to purchase treasury stock. Students…

  19. Making Ends Meet: Private Food Assistance and the Working Poor. Discussion Paper.

    ERIC Educational Resources Information Center

    Nichols-Casebolt, Ann; Morris, Patricia McGrath

    This study examined characteristics of employed households dependent upon private nutrition programs to help make ends meet. Data were derived from an ongoing study of households receiving food assistance from Virginia food pantries and soup kitchens. In 1997, researchers produced a list of all food pantries and soup kitchens in one region and…

  20. Legislative Alphabet Soup: Federal Laws that Affect Your Work as a Library Media Specialist

    ERIC Educational Resources Information Center

    Adams, Helen R.

    2006-01-01

    Today, federal laws often seem like an alphabet soup with acronyms like CIPA (Children's Internet Protection Act), CTEA (Copyright Term Extension Act), ADA (Americans with Disabilities Act), IDEA (Individuals with Disabilities Education Act), YMCA (Digital Millennium Copyright Act), and NC LB (No Child Left Behind). These letters stand for federal…

  1. Bowls for the Hungry

    ERIC Educational Resources Information Center

    Greenwood, Nate

    2009-01-01

    In this article, the author describes how to make soup bowls as a class project. The slab method is used to construct the soup bowls, but bowls could just as easily be made on the potter's wheel for advanced students, using the pinch method with beginners, or with the coil method for intermediate students. Found objects from around a garage or…

  2. Spectrum Orbit Utilization Program documentation: SOUP5 version 3.8 user's manual, volume 1, chapters 1 through 5

    NASA Technical Reports Server (NTRS)

    Davidson, J.; Ottey, H. R.; Sawitz, P.; Zusman, F. S.

    1985-01-01

    The underlying engineering and mathematical models as well as the computational methods used by the Spectrum Orbit Utilization Program 5 (SOUP5) analysis programs are described. Included are the algorithms used to calculate the technical parameters, and references to the technical literature. The organization, capabilities, processing sequences, and processing and data options of the SOUP5 system are described. The details of the geometric calculations are given. Also discussed are the various antenna gain algorithms; rain attenuation and depolarization calculations; calculations of transmitter power and received power flux density; channelization options, interference categories, and protection ratio calculation; generation of aggregrate interference and margins; equivalent gain calculations; and how to enter a protection ratio template.

  3. ALICE in the early Universe wonderland

    NASA Astrophysics Data System (ADS)

    Di Nezza, Pasquale

    2012-03-01

    In these years the Large Hadron Collider (LHC) at CERN is probing, for the first time, physics at energy scales more than an order of magnitude beyond that of the Standard Model. These experiments explore an energy regime of particle physics where phenomena, such as supersymmetry and Grand Unified Theories, may become relevant. Certainly, the LHC should shed light on the mechanism of electroweak symmetry breaking and may discover the first fundamental scalar particle seen in nature. The collisions of heavy ions (Pb - Pb) will create the same "soup" the early Universe had at the epoch of 10-5 seconds. In general, there is a strong and growing interplay between particle physics and cosmology, in particular in the possible production of mini black holes and dark matter candidates like the lightest neutralino in the MSSM.

  4. A photoelectric skylight polarimeter.

    PubMed

    Hariharan, T A; Sekera, Z

    1966-09-01

    A photoelectric skylight polarimeter to measure directly the Stokes parameters for plane polarized light is described. The basic principle of the instrument consists in the simultaneous measurement of the intensity of light (in the chosen spectral region) transmitted by polarizers oriented in four specific directions. The main features and performance characteristics of the instrument are briefly discussed.

  5. The Skylab ten color photoelectric polarimeter. [sky brightness

    NASA Technical Reports Server (NTRS)

    Weinberg, J. L.; Hahn, R. C.; Sparrow, J. G.

    1975-01-01

    A 10-color photoelectric polarimeter was used during Skylab missions SL-2 and SL-3 to measure sky brightness and polarization associated with zodiacal light, background starlight, and the spacecraft corona. A description is given of the instrument and observing routines together with initial results on the spacecraft corona and polarization of the zodiacal light.

  6. Snapshot imaging polarimeters using spatial modulation

    NASA Astrophysics Data System (ADS)

    Luo, Haitao

    The recent demonstration of a novel snapshot imaging polarimeter using the fringe modulation technique shows a promise in building a compact and moving-parts-free device. As just demonstrated in principle, this technique has not been adequately studied. In the effort of advancing this technique, we build a complete theory framework that can address the key issues regarding the polarization aberrations caused by using the functional elements. With this model, we can have the necessary knowledge in designing, analyzing and optimizing the systems. Also, we propose a broader technique that uses arbitrary modulation instead of sinusoidal fringes, which can give us more engineering freedom and can be the solution of achromatizing the system. In the hardware aspect, several important progresses are made. We extend the polarimeter technique from visible to middle wavelength infrared by using the yttrium vanadate crystals. Also, we incorporate a Savart Plate polarimter into a fundus camera to measure the human eye's retinal retardance, useful information for glaucoma diagnosis. Thirdly, a world-smallest imaging polarimeter is proposed and demonstrated, which may open many applications in security, remote sensing and bioscience.

  7. A Millimeter Polarimeter for the 45-m Telescope at Nobeyama

    NASA Astrophysics Data System (ADS)

    Shinnaga, Hiroko; Tsuboi, Masato; Kasuga, Takashi

    1999-04-01

    We have designed and constructed a tunable polarimeter to cover frequencies from 35 GHz to 250 GHz (8.6 mm and 1.2 mm in wavelength) for the 45-m telescope at Nobeyama Radio Observatory. Both circular and linear polarizations can be measured by the polarimeter. The insertion loss was measured to be 0.14 +/- 0.05 dB in the 100-GHz band. The overall instrumental polarization of the system in the 100 GHz band is as low as <= 3%. The performance of the polarimeter in astronomical observations was tested by simultaneously measuring the linear polarization of the J = 2--1 transition of SiO in the v = 0 and 1 states at 86 GHz toward VY Canis Majoris. The observation revealed that the J = 2--1 emission in the v = 0 state of the object is highly linear polarized, which suggests that the emission originates through maser action in the circumstellar region. The details of the design, construction, and tests are presented. Nobeyama Radio Observatory is a branch of the National Astronomical Observatory, operated by the Ministry of Education, Science, Sports and Culture.

  8. A new three-band, two beam astronomical photo-polarimeter

    NASA Astrophysics Data System (ADS)

    Srinivasulu, G.; Raveendran, A. V.; Muneer, S.; Mekkaden, M. V.; Jayavel, N.; Somashekar, M. R.; Sagayanathan, K.; Ramamoorthy, S.; Rosario, M. J.; Jayakumar, K.

    2014-09-01

    We designed and built a new astronomical photo-polarimeter that can measure linear polarization simultaneously in three spectral bands. It has a Calcite beam-displacement prism as the analyzer. The ordinary and extra-ordinary emerging beams in each spectral bands are quasi-simultaneously detected by the same photomultiplier by using a high speed rotating chopper. A rotating superachromatic Pancharatnam halfwave plate is used to modulate the light incident on the analyzer. The spectral bands are isolated using appropriate dichroic and glass filters. We show that the reduction of 50% in the efficiency of the polarimeter because of the fact that the intensities of the two beams are measured alternately is partly compensated by the reduced time to be spent on the observation of the sky background. The use of a beam-displacement prism as the analyzer completely removes the polarization of background skylight, which is a major source of error during moonlit nights, especially, in the case of faint stars. The field trials that were carried out by observing several polarized and unpolarized stars show the performance of the polarimeter to be satisfactory.

  9. The ability to use remote polarization studies of Earth from space in the national economy (Project of the onboard filter panoramic polarimeter)

    NASA Astrophysics Data System (ADS)

    Nevodovskyi, P. V.; Vidmachenko, A. P.; Geraimchuk, M. D.; Ivahiv, O. V.

    2016-10-01

    Remote polarization studies are a very powerful method of solving of astronomical tasks with the study of the physical properties of the planets and their atmospheres. It allows research of objects as in situ, so in vitro, and has many other advantages. To use this method has already been developed and are continuing the development of many various special instruments called polarimeters. The essence of the space experiment consists in the fact to using the polarimeter installed on board a micro satellite, systematically, during each of its revolutions around the Earth, to monitor a polarization components of a diffusely reflected by atmosphere solar radiation in different, previously stipulated wavelengths. There are a lot of the optical schemes, which are used in devices of measuring and monitoring of parameters of polarized radiation, including those into space experiments of probing of the Earth's atmosphere from orbit of satellites. In this paper we analyze the potential for use of filter-polarimeter to measure the Stokes vector components.

  10. Mott Polarimeter Upgrade at Jefferson Lab

    NASA Astrophysics Data System (ADS)

    McHugh, M.; Opper, A. K.; Grames, J.; Poelker, M.; Suleiman, R.; Horowitz, C.; Rhodes, S.; Roca Maza, X.; Sinclair, C.

    2013-10-01

    A Mott polarimeter with a design optimized for 5.5 MeV/c has been in routine use at the CEBAF accelerator for well over a decade, providing polarization measurements approaching 1% accuracy. Measurements with different target elements (Au, Ag, Cu) over decades of target thicknesses (100 - 10,000 angstroms), and beam energies between 2 and 8 MeV allow us to determine the effective analyzing power with a high degree of certainty. Recent and planned improvements in our polarimeter configuration, detectors and data acquisition system, coupled with a low 31 MHz repetition rate beam allow us to distinguish and suppress electrons that do not originate from the target foil. This work coupled with a significant effort to produce a detailed GEANT4 model of the polarimeter is part of an effort to determine systematic uncertainties at the level of the theoretically calculated analyzing power. We describe our activities and a series of planned measurements that will allow us to demonstrate and possibly improve the precision and accuracy of polarization measurements at JLab, as required for future parity violation experiments.

  11. Design study of the PEPSI polarimeter for the LBT

    NASA Astrophysics Data System (ADS)

    Hofmann, A.; Strassmeier, K. G.; Woche, M.

    2002-07-01

    We present the conceptual design of the two polarimetric channels of the PEPSI spectropolarimeter for the Large Binocular Telescope (LBT). The two direct Gregorian f/15 focii of the LBT will take up two identical but independent full-Stokes IQUV polarimeters that themselves fiberfeed a high-resolution Echelle spectrograph (see the accompanying paper by Zerbi et al.). The polarizing units will be based on super-achromatic Fresnel-rhomb retarders and Foster prisms. A total of four fibers are foreseen to simultaneously direct two ordinary and two extraordinary light beams to the Echelle spectrograph. Both polarimetric units are layed out in a modular design, each one optimized to the polarization state in which it is used. A number of observing modes can be chosen that are optimized to the type of polarization that is expected from the target, e.g. circularly and linearly polarized light simultaneously, or linearly polarized light in both polarimeters, or integral light from one and polarized light from the other telescope, a.s.o.. Calibration would be provided for each polarimeter separately.

  12. Canadian Led X-ray Polarimeter Mission CXP

    NASA Technical Reports Server (NTRS)

    Kaspi, V.; Hanna, D.; Weisskopf, M.; Ramsey, B.; Ragan, K.; Vachon, B.; Elsner, R.; Heyl, J.; Pavlov, G.; Cumming, A.; hide

    2006-01-01

    We propose a Canadian-led X-ray Polarimetry Mission (CXP), to include a scattering X-ray Polarimeter and sensitive All-Sky X-ray Monitor (ASXM). Polarimetry would provide a new observational window on black holes, neutron stars, accretion disks and jets, and the ASXM would offer sensitive monitoring of the volatile X-ray sky. The envisioned polarimeter consists of a hollow scattering beryllium cone surrounded by an annular proportional counter, in a simple and elegant design that is reliable and low-risk. It would be sensitive in the 6-30 keV band to approx. 3% polarization in approx. 30 Galactic sources and 2 AGN in a baseline 1-yr mission, and have sensitivity greater than 10 times that of the previous X-ray polarimeter flown (NASA's OSO-8, 1975-78) for most sources. This X-ray polarimeter would tackle questions like, Do black holes spin?, How do pulsars pulse?, What is the geometry of the magnetic field in accreting neutron stars? Where and how are jets produced in microquasars and AGN?, What are the geometries of many of the most famous accretion-disk systems in the sky? This will be done using a novel and until-now unexploited technique that will greatly broaden the available observational phase space of compact objects by adding to timing and spectroscopy observations of polarization fraction and position angle as a function of energy. The All-Sky X-ray Monitor would scan for transients, both as potential targets for the polarimeter but also as a service to the worldwide astronomical community. The entire CXP mission could be flown for $40- 60M CDN, according to estimates by ComDev International, and could be built entirely in Canada. It would fall well within the CSA's SmallSat envelope and would empower the growing and dynamic Canadian High-Energy Astrophysics community with world leadership in a potentially high impact niche area.

  13. Noninvasive and Painless Urine Glucose Detection by Using Computer-based Polarimeter

    NASA Astrophysics Data System (ADS)

    Sutrisno; Laksono, Y. A.; Hidayat, N.

    2017-05-01

    Diabetes kills millions of people worldwide each year. It challenges us as researchers to give contribution in early diagnosis to ensure a healthy life. As a matter of fact, common glucose testing devices that have been widely used so far are, at least, glucose meter and urine glucose test strip. The glucose meter ordinarily requires blood taken from patient’s finger. The glucose test strip uses patient’s urine but records unspecific urine glucose level, since the strip only provides the glucose level in some particular ranges. Instead of detecting the glucose level in blood and using the non-specific technique, a noninvasive and painless technique that can detect glucose level accurately will provide a more feasible approach for diabetes diagnosis. The noninvasive and painless urine glucose level monitoring by means of computer-based polarimeter is presented in this paper. The instrument consisted of a power source, a sample box, a light sensor, a polarizer, an analyzer, an analog to digital converter (ADC), and a computer. The concentration of urine glucose concentration was evaluated from the curve of the change in detected optical rotation angle and output potential by the computer-based polarimeter. Statistical analyses by means of Gaussian fitting and linear regression were applied to investigate the rotation angle and urine glucose concentration, respectively. From our experiment, the urine glucose level, measured by glucose test strips, of the normal patient was 100 mg/dl, and the diabetic patient was 500 mg/dl. Our polarimeter even read more precise values for the urine glucose concentrations of those normal and diabetic of the same patients, i.e. 50.61 mg/dl and 502.41 mg/dl, respectively. In other words, the results showed that our polarimeter was able to quantitatively measure the urine glucose level more accurate than urine glucose test strips. Hence, this computer-based polarimeter could be used as an alternative for early detection of urine glucose with noninvasive and painless characteristics.

  14. Hot soup! Correlating the severity of liquid scald burns to fluid and biomedical properties.

    PubMed

    Loller, Cameron; Buxton, Gavin A; Kerzmann, Tony L

    2016-05-01

    Burns caused by hot drinks and soups can be both debilitating and costly, especially to pediatric and geriatric patients. This research is aimed at better understanding the fluid properties that can influence the severity of skin burns. We use a standard model which combines heat transfer and biomedical equations to predict burn severity. In particular, experimental data from a physical model serves as the input to our numerical model to determine the severity of scald burns as a consequence of actual fluid flows. This technique enables us to numerically predict the heat transfer from the hot soup into the skin, without the need to numerically estimate the complex fluid mechanics and thermodynamics of the potentially highly viscous and heterogeneous soup. While the temperature of the soup is obviously is the most important fact in determining the degree of burn, we also find that more viscous fluids result in more severe burns, as the slower flowing thicker fluids remain in contact with the skin for longer. Furthermore, other factors can also increase the severity of burn such as a higher initial fluid temperature, a greater fluid thermal conductivity, or a higher thermal capacity of the fluid. Our combined experimental and numerical investigation finds that for average skin properties a very viscous fluid at 100°C, the fluid must be in contact with the skin for around 15-20s to cause second degree burns, and more than 80s to cause a third degree burn. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.

  15. AYURVEDIC RATIONALE OF THE SOUTHERN INDIAN VEGETABLE SOUP SAARU OR RASAM

    PubMed Central

    Vijayalakshmi, B.; Swamy, B.V Kumara; Shantha, T.R.

    1998-01-01

    Spices are historically known contributions to the world. The credit for identifying the spices with medicinal and culinary values goes to Ayurveda. Saaru or Rasam is a very popular soup used all over southern India. In this paper an attempt has been made to present the ayurvedic rationale behind formulating the receipt of saaru or rasam. PMID:22556843

  16. Putting the Learning in Service Learning: From Soup Kitchen Models to the Black Metropolis Model

    ERIC Educational Resources Information Center

    Manley, Theodoric, Jr.; Buffa, Avery S.; Dube, Caleb; Reed, Lauren

    2006-01-01

    Results of the Black Metropolis Model (BMM) of service learning are analyzed and illustrated in this article to explain how to "put the learning in service learning." There are many soup kitchens or nontransforming models of service learning where students are asked to serve needy populations but internalize and learn little about the…

  17. Superchilled storage (-2.5 ± 1°C) extends the retention of taste-active and volatile compounds of yellow-feather chicken soup.

    PubMed

    Li, Xiao; Zhu, Jing; Qi, Jun; Wang, Peng; Xu, Xinglian; Zhou, Guanghong

    2018-06-01

    This work investigated the effects of refrigerated storage (RS: 4 ± 1°C) and superchilled storage (SS: -2.5 ± 1°C) on non-volatile and volatile compounds in chicken soup made from Chinese yellow-feather broilers. The results from total viable count (TVC) and coliform analysis showed that soups were safe for human consumption after a storage period of 42 days. SS resulted in a significantly (p < .05) higher content of free amino acids (umami and sweet taste) and 5'-nucleotides (inosine 5'-monophosphate and adenosine 5'-monophosphate) from 21 to 42 days compared to RS. Hexanal, (E)-2-decenal, (E,E)-2,4-decadienal and 2-pentyl furan were described as the primary odorants. SS showed significantly lower values (p < .05) for ketones and hydrocarbons, higher values for aldehydes and alcohols from 14 to 42 days, when compared to RS. The results suggest that SS improved the flavor retention of chicken soup after 21 days of storage and is a potential alternative treatment compared to RS. © 2018 Japanese Society of Animal Science.

  18. Effect of a barley-vegetable soup on plasma carotenoids and biomarkers of cardiovascular disease.

    PubMed

    Bacchetti, Tiziana; Tullii, Domenico; Masciangelo, Simona; Gesuita, Rosaria; Skrami, Edlira; Brugè, Francesca; Silvestri, Sonia; Orlando, Patrick; Tiano, Luca; Ferretti, Gianna

    2015-07-01

    Functional foods that provide benefits beyond their traditional nutritional value have attracted much interest. Aim of the study was to evaluate the nutritional and the functional properties of a frozen ready-to-eat soup containing barley and pigmented vegetables. Both glycaemic index and the glyceamic load of ready-to-eat soup were evaluated in vivo. Moreover the bioavailability of carotenoids (lutein and beta-carotene) and the effect on lipid profile and lipid peroxidation were studied in 38 volunteers whose diet was supplemented for two weeks with a daily portion (250 g) of the ready-to-eat soup. Plasma levels of carotenoids (lutein and beta-carotene) and plasma total antioxidant capacity significantly increased after 2 weeks of treatment. Furthermore, we observed a decrease in the levels of lipids (total cholesterol and low density lipoprotein-cholesterol) and of markers of lipid peroxidation (oxidized low density lipoprotein and lipid hydroperoxides) in plasma of all subjects. The glyceamic index of the product was 36, therefore it could be considered a low glyceamic index food. An accurate selection of vegetable foods results in a palatable and healthy product that provides benefits on plasma lipids and lipid peroxidation (Protocol number 211525).

  19. [Socio-demographic and food insecurity characteristics of soup-kitchen users in Brazil].

    PubMed

    Godoy, Kátia Cruz; Sávio, Karin Eleonora Oliveira; Akutsu, Rita de Cássia; Gubert, Muriel Bauermann; Botelho, Raquel Braz Assunção

    2014-06-01

    This study aimed to characterize users of a government soup-kitchen program and the association with family food insecurity, using a cross-sectional design and random sample of 1,637 soup-kitchen users. The study used a questionnaire with socioeconomic variables and the Brazilian Food Insecurity Scale, and measured weight and height. The chi-square test was applied, and the crude and adjusted prevalence ratios (PR) were calculated using Poisson regression. Prevalent characteristics included per capita income ranging from one-half to one minimum wage (35.1%), complete middle school (39.8%), and food security (59.4%). Users in the North of Brazil showed the worst data: incomplete primary school (39.8%), per capita income up to one-half the minimum wage (50.8%), and food insecurity (55.5%). Prevalence ratios for food insecurity were higher among users with per capita income up to one-fourth the minimum wage (p < 0.05). Income was the only variable that remained associated with higher prevalence of food insecurity in the adjusted PR. Knowing the characteristics of soup-kitchen users with food insecurity can help orient the program's work, location, and operations.

  20. Effect of a barley-vegetable soup on plasma carotenoids and biomarkers of cardiovascular disease

    PubMed Central

    Bacchetti, Tiziana; Tullii, Domenico; Masciangelo, Simona; Gesuita, Rosaria; Skrami, Edlira; Brugè, Francesca; Silvestri, Sonia; Orlando, Patrick; Tiano, Luca; Ferretti, Gianna

    2015-01-01

    Functional foods that provide benefits beyond their traditional nutritional value have attracted much interest. Aim of the study was to evaluate the nutritional and the functional properties of a frozen ready-to-eat soup containing barley and pigmented vegetables. Both glycaemic index and the glyceamic load of ready-to-eat soup were evaluated in vivo. Moreover the bioavailability of carotenoids (lutein and beta-carotene) and the effect on lipid profile and lipid peroxidation were studied in 38 volunteers whose diet was supplemented for two weeks with a daily portion (250 g) of the ready-to-eat soup. Plasma levels of carotenoids (lutein and beta-carotene) and plasma total antioxidant capacity significantly increased after 2 weeks of treatment. Furthermore, we observed a decrease in the levels of lipids (total cholesterol and low density lipoprotein-cholesterol) and of markers of lipid peroxidation (oxidized low density lipoprotein and lipid hydroperoxides) in plasma of all subjects. The glyceamic index of the product was 36, therefore it could be considered a low glyceamic index food. An accurate selection of vegetable foods results in a palatable and healthy product that provides benefits on plasma lipids and lipid peroxidation (Protocol number 211525). PMID:26236103

  1. Exploring a possible origin of a 14 deg y-normal spin tilt at RHIC polarimeter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meot, F.; Huang, H.

    2015-06-15

    A possible origin of a 14 deg y-normal spin n → 0 tilt at the polarimeter is in snake angle defects. This possible cause is investigated by scanning the snake axis angle µ, and the spin rotation angle at the snake, φ, in the vicinity of their nominal values.

  2. POLICAN: A near-infrared imaging polarimeter at OAGH

    NASA Astrophysics Data System (ADS)

    Devaraj, R.; Luna, A.; Carrasco, L.; Mayya, Y. D.; Serrano-Bernal, O.

    2017-07-01

    We present a near-infrared linear imaging polarimeter POLICAN, developed for the Cananea near-infrared camera (CANICA) at the 2.1m telescope of the Guillermo Haro Astrophysical Observatory (OAGH) located at Cananea, Sonora, México. POLICAN reaches a limiting magnitude to about 16th mag with a polarimetric accuracy of about 1% for bright sources.

  3. Polarimeter based on video matrix

    NASA Astrophysics Data System (ADS)

    Pavlov, Andrey; Kontantinov, Oleg; Shmirko, Konstantin; Zubko, Evgenij

    2017-11-01

    In this paper we present a new measurement tool - polarimeter, based on video matrix. Polarimetric measure- ments are usefull, for example, when monitoring water areas pollutions and atmosphere constituents. New device is small enough to mount on unmanned aircraft vehicles (quadrocopters) and stationary platforms. Device and corresponding software turns it into real-time monitoring system, that helps to solve some research problems.

  4. Snapshot retinal imaging Mueller matrix polarimeter

    NASA Astrophysics Data System (ADS)

    Wang, Yifan; Kudenov, Michael; Kashani, Amir; Schwiegerling, Jim; Escuti, Michael

    2015-09-01

    Early diagnosis of glaucoma, which is a leading cause for visual impairment, is critical for successful treatment. It has been shown that Imaging polarimetry has advantages in early detection of structural changes in the retina. Here, we theoretically and experimentally present a snapshot Mueller Matrix Polarimeter fundus camera, which has the potential to record the polarization-altering characteristics of retina with a single snapshot. It is made by incorporating polarization gratings into a fundus camera design. Complete Mueller Matrix data sets can be obtained by analyzing the polarization fringes projected onto the image plane. In this paper, we describe the experimental implementation of the snapshot retinal imaging Mueller matrix polarimeter (SRIMMP), highlight issues related to calibration, and provide preliminary images acquired from the camera.

  5. POL-2: a polarimeter for the James-Clerk-Maxwell telescope

    NASA Astrophysics Data System (ADS)

    Friberg, Per; Bastien, Pierre; Berry, David; Savini, Giorgio; Graves, Sarah F.; Pattle, Kate

    2016-07-01

    The POL-2 polarimeter for the SCUBA-2 10 000 pixel Terahertz camera on the James Clerk Maxwell Telescope (JCMT) in it's late state of commissioning. Proposals have been accepted for POL-2 and general observing will start in August 2016. SCUBA-2 has a field of view of 43 arcmin at both of the 850 and 450 μm focal planes. POL-2 will map the sky in the the 850 μm band. The POL-2 polarimeter utilizes three optical components: a half wave plate and two wire-grid polarizers used as calibrator and analyzer covering the full field of SCUBA-2. We describe the instrument, data acquisition and features/artifacts that have been encountered during the commissioning.

  6. Design and Deployment of a Multichroic Polarimeter Array on the Atacama Cosmology Telescope

    NASA Technical Reports Server (NTRS)

    Datta, R.; Austermann, J.; Beall, J. A.; Becker, D.; Coughlin, K. P.; Duff, S. M.; Gallardo, P.A.; Grace, E.; Hasselfield, M.; Henderson, S. W.; hide

    2016-01-01

    We present the design and the preliminary on-sky performance with respect to beams and pass bands of a multichroic polarimeter array covering the 90 and 146 GHz cosmic microwave background bands and its enabling broad-band optical system recently deployed on the Atacama Cosmology Telescope (ACT). The constituent pixels are feedhorn-coupled multichroic polarimeters fabricated at NIST. This array is coupled to the ACT telescope via a set of three silicon lenses incorporating novel broad-band metamaterial anti-reflection coatings. This receiver represents the first multichroic detector array deployed for a CMB experiment and paves the way for the extensive use of multichroic detectors and broad-band optical systems in the next generation of CMB experiments.

  7. Design and Deployment of a Multichroic Polarimeter Array on the Atacama Cosmology Telescope

    NASA Astrophysics Data System (ADS)

    Datta, R.; Austermann, J.; Beall, J. A.; Becker, D.; Coughlin, K. P.; Duff, S. M.; Gallardo, P. A.; Grace, E.; Hasselfield, M.; Henderson, S. W.; Hilton, G. C.; Ho, S. P.; Hubmayr, J.; Koopman, B. J.; Lanen, J. V.; Li, D.; McMahon, J.; Munson, C. D.; Nati, F.; Niemack, M. D.; Page, L.; Pappas, C. G.; Salatino, M.; Schmitt, B. L.; Schillaci, A.; Simon, S. M.; Staggs, S. T.; Stevens, J. R.; Vavagiakis, E. M.; Ward, J. T.; Wollack, E. J.

    2016-08-01

    We present the design and the preliminary on-sky performance with respect to beams and passbands of a multichroic polarimeter array covering the 90 and 146 GHz cosmic microwave background bands and its enabling broad-band optical system recently deployed on the Atacama Cosmology Telescope (ACT). The constituent pixels are feedhorn-coupled multichroic polarimeters fabricated at NIST. This array is coupled to the ACT telescope via a set of three silicon lenses incorporating novel broad-band metamaterial anti-reflection coatings. This receiver represents the first multichroic detector array deployed for a CMB experiment and paves the way for the extensive use of multichroic detectors and broad-band optical systems in the next generation of CMB experiments.

  8. Managing Systematic Errors in a Polarimeter for the Storage Ring EDM Experiment

    NASA Astrophysics Data System (ADS)

    Stephenson, Edward J.; Storage Ring EDM Collaboration

    2011-05-01

    The EDDA plastic scintillator detector system at the Cooler Synchrotron (COSY) has been used to demonstrate that it is possible using a thick target at the edge of the circulating beam to meet the requirements for a polarimeter to be used in the search for an electric dipole moment on the proton or deuteron. Emphasizing elastic and low Q-value reactions leads to large analyzing powers and, along with thick targets, to efficiencies near 1%. Using only information obtained comparing count rates for oppositely vector-polarized beam states and a calibration of the sensitivity of the polarimeter to rate and geometric changes, the contribution of systematic errors can be suppressed below the level of one part per million.

  9. Spectrum Orbit Utilization Program Documentation: SOUP5 Version 3.8 User's Manual, Volume 2, Appendices a Through G

    NASA Technical Reports Server (NTRS)

    Davidson, J.; Ottey, H. R.; Sawitz, P.; Zusman, F. S.

    1985-01-01

    The appendixes of the user manual are presented. Input forms which may be used to prepare data for the SOUP5V3.4 of the R2BCSAT-83 data base are given. The IBM job control language which can be used to run the SOUP5 system from a magnetic tape is described. Copies of a run using the delivered tape and IBM OS/MVS Job Control Language card deck are illustrated. Numerical limits on scenario data requests are listed. Error handling, error messages and editing procedures are also listed. Instructions as to how to enter a protection ratio template are given. And relation between PARC prameter, channelization, channel families, and interference categories are also listed.

  10. Detector characterization, optimization, and operation for ACTPol

    NASA Astrophysics Data System (ADS)

    Grace, Emily Ann

    2016-01-01

    Measurements of the temperature anisotropies of the Cosmic Microwave Background (CMB) have provided the foundation for much of our current knowledge of cosmology. Observations of the polarization of the CMB have already begun to build on this foundation and promise to illuminate open cosmological questions regarding the first moments of the universe and the properties of dark energy. The primary CMB polarization signal contains the signature of early universe physics including the possible imprint of inflationary gravitational waves, while a secondary signal arises due to late-time interactions of CMB photons which encode information about the formation and evolution of structure in the universe. The Atacama Cosmology Telescope Polarimeter (ACTPol), located at an elevation of 5200 meters in Chile and currently in its third season of observing, is designed to probe these signals with measurements of the CMB in both temperature and polarization from arcminute to degree scales. To measure the faint CMB polarization signal, ACTPol employs large, kilo-pixel detector arrays of transition edge sensor (TES) bolometers, which are cooled to a 100 mK operating temperature with a dilution refrigerator. Three such arrays are currently deployed, two with sensitivity to 150 GHz radiation and one dichroic array with 90 GHz and 150 GHz sensitivity. The operation of these large, monolithic detector arrays presents a number of challenges for both assembly and characterization. This thesis describes the design and assembly of the ACTPol polarimeter arrays and outlines techniques for their rapid characterization. These methods are employed to optimize the design and operating conditions of the detectors, select wafers for deployment, and evaluate the baseline array performance. The results of the application of these techniques to wafers from all three ACTPol arrays is described, including discussion of the measured thermal properties and time constants. Finally, aspects of the characterization and calibration of the deployed detectors during field operations are discussed.

  11. Spectro-Polarimetry of Fine-Grained Ice and Dust Surfaces Measured in the Laboratory to Study Solar System Objects and Beyond

    NASA Astrophysics Data System (ADS)

    Poch, O.; Cerubini, R.; Pommerol, A.; Thomas, N.; Schmid, H. M.; Potin, S.; Beck, P.; Schmitt, B.; Brissaud, O.; Carrasco, N.; Szopa, C.; Buch, A.

    2017-12-01

    The polarization of the light is very sensitive to the size, morphology, porosity and composition of the scattering particles. As a consequence, polarimetric observations could significantly complement observations performed in total light intensity, providing additional constraints to interpret remote sensing observations of Solar System and extra-solar objects. This presentation will focus on measurements performed in the laboratory on carefully characterized surface samples, providing reference data that can be used to test theoretical models and predict or interpret spectro-polarimetric observations. Using methods developed in the Laboratory for Outflow Studies of Sublimating Materials (LOSSy) at the University of Bern, we produce well-characterized and reproducible surfaces made of water ice particles having different grain sizes and porosities, as well as mineral/organic dusts, pure or mixed together, as analogues of planetary or small bodies surfaces. These surface samples are illuminated with a randomly polarized light source simulating the Sun. The polarization of their scattered light is measured at multiple phase angles and wavelengths, allowing to study the shape of the polarimetric phase curves and their spectral dependence, with two recently developed setups: The POLarimeter for Icy Samples (POLICES), at the University of Bern, allows the measurement of the weak polarization of ice surfaces from 400 to 800 nm, with direct application to icy satellites. Using a precision Stokes polarimeter, this setup is also used to study the spectral variations of circular polarization in the light scattered by biotic versus abiotic surfaces. The Spectrogonio radiometer with cHanging Angles for Detection Of Weak Signals (SHADOWS), at IPAG (University of Grenoble Alpes), measures linear polarization spectra from 0.35 to 5 μm in the light scattered by dark meteorite powders or icy samples, with application to primitive objects of the Solar System (asteroids, comets).

  12. Simulation and Laboratory results of the Hard X-ray Polarimeter: X-Calibur

    NASA Astrophysics Data System (ADS)

    Guo, Qingzhen; Beilicke, M.; Kislat, F.; Krawczynski, H.

    2014-01-01

    X-ray polarimetry promises to give qualitatively new information about high-energy sources, such as binary black hole (BH) systems, Microquasars, active galactic nuclei (AGN), GRBs, etc. We designed, built and tested a hard X-ray polarimeter 'X-Calibur' to be flown in the focal plane of the InFOCuS grazing incidence hard X-ray telescope in 2014. X-Calibur combines a low-Z Compton scatterer with a CZT detector assembly to measure the polarization of 20- 80 keV X-rays making use of the fact that polarized photons Compton scatter preferentially perpendicular to the E field orientation. X-Calibur achieves a high detection efficiency of order unity. We optimized of the design of the instrument based on Monte Carlo simulations of polarized and unpolarized X-ray beams and of the most important background components. We have calibrated and tested X-Calibur extensively in the laboratory at Washington University and at the Cornell High-Energy Synchrotron Source (CHESS). Measurements using the highly polarized synchrotron beam at CHESS confirm the polarization sensitivity of the instrument. In this talk we report on the optimization of the design of the instrument based on Monte Carlo simulations, as well as results of laboratory calibration measurements characterizing the performance of the instrument.

  13. The Primordial Inflation Explorer (PIXIE): A Nulling Polarimeter for Cosmic Microwave Background Observations

    NASA Technical Reports Server (NTRS)

    Kogut, Alan J.; Fixsen, D. J.; Chuss, D. T.; Dotson, J.; Dwek, E.; Halpern, M.; Hinshaw, G. F.; Meyer, S. M.; Moseley, S. H.; Seiffert, M. D.; hide

    2011-01-01

    The Primordial Inflation Explorer (PIXIE) is a concept for an Explorer-class mission to measure the gravity-wave signature of primordial inflation through its distinctive imprint on the linear polarization of the cosmic microwave background. The instrument consists of a polarizing Michelson interferometer configured as a nulling polarimeter to measure the difference spectrum between orthogonal linear polarizations from two co-aligned beams. Either input can view the sky or a temperature-controlled absolute reference blackbody calibrator. Rhe proposed instrument can map the absolute intensity and linear polarization (Stokes I, Q, and U parameters) over the full sky in 400 spectral channels spanning 2.5 decades in frequency from 30 GHz to 6 THz (1 cm to 50 micron wavelength). Multi-moded optics provide background-limited sensitivity using only 4 detectors, while the highly symmetric design and multiple signal modulations provide robust rejection of potential systematic errors. The principal science goal is the detection and characterization of linear polarization from an inflationary epoch in the early universe, with tensor-to-scalar ratio r < 10..3 at 5 standard deviations. The rich PIXIE data set can also constrain physical processes ranging from Big Bang cosmology to the nature of the first stars to physical conditions within the interstellar medium of the Galaxy.

  14. SPIDER: probing the early Universe with a suborbital polarimeter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fraisse, A.A.; Chiang, H.C.; Ade, P.A.R.

    2013-04-01

    We evaluate the ability of SPIDER, a balloon-borne polarimeter, to detect a divergence-free polarization pattern (B-modes) in the cosmic microwave background (CMB). In the inflationary scenario, the amplitude of this signal is proportional to that of the primordial scalar perturbations through the tensor-to-scalar ratio r. We show that the expected level of systematic error in the SPIDER instrument is significantly below the amplitude of an interesting cosmological signal with r = 0.03. We present a scanning strategy that enables us to minimize uncertainty in the reconstruction of the Stokes parameters used to characterize the CMB, while accessing a relatively widemore » range of angular scales. Evaluating the amplitude of the polarized Galactic emission in the SPIDER field, we conclude that the polarized emission from interstellar dust is as bright or brighter than the cosmological signal at all SPIDER frequencies (90 GHz, 150 GHz, and 280 GHz), a situation similar to that found in the ''Southern Hole.'' We show that two ∼ 20-day flights of the SPIDER instrument can constrain the amplitude of the B-mode signal to r < 0.03 (99% CL) even when foreground contamination is taken into account. In the absence of foregrounds, the same limit can be reached after one 20-day flight.« less

  15. Recent Progress of the HL-2A Multi-Channel HCOOH Laser Interferometer/Polarimeter

    NASA Astrophysics Data System (ADS)

    Li, Yonggao; Zhou, Yan; Deng, Zhongchao; Li, Yuan; Yi, Jiang; Wang, Haoxi

    2015-05-01

    A multichannel methanoic acid (HCOOH, λ = 432.5 μm) laser interferometer/polarimeter is being developed from the previous eight-channel hydrogen cyanide (HCN, λ = 337 μm) laser interferometer in the HL-2A tokamak. A conventional Michelson-type interometer is used for the electron density measurement, and a Dodel-Kunz-type polarimeter is used for the Faraday rotation effect measurement, respectively. Each HCOOH laser can produce a linearly polarized radiation at a power lever of ˜30 mW, and a power stability <10% in 50 min. A beam waist (diameter d0 ≈12.0 mm, about 200 mm away from the outlet) is finally determined through a chopping modulation technique. The latest optical layout of the interferometer/polarimeter has been finished, and the hardware data processing system based on the fast Fourier transform phase-comparator technique is being explored. In order to demonstrate the feasibility of the diagnostic scheme, two associated bench simulation experiments were carried out in the laboratory, in which the plasma was simulated by a piece of polytetrafluoroethene plate, and the Faraday rotation effect was simulated by a rotating half-wave plate. Simulation results agreed well with the initial experimental conditions. At present, the HCOOH laser interferometer/polarimeter system is being assembled on HL-2A, and is planned to be applied in the 2014-2015 experimental campaign. supported by the National Magnetic Confinement Fusion Science Programs of China (Nos. 2010GB101002 and 2014GB109001), and National Natural Science Foundation of China (Nos. 11075048 and 11275059)

  16. Multiparameter measurement utilizing poloidal polarimeter for burning plasma reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Imazawa, Ryota; Kawano, Yasunori; Itami, Kiyoshi

    2014-08-21

    The authors have made the basic and applied research on the polarimeter for plasma diagnostics. Recently, the authors have proposed an application of multiparameter measurement (magnetic field, B, electron density, n{sub e}, electron temperature, T{sub e}, and total plasma current, I{sub p}) utilizing polarimeter to future fusion reactors. In this proceedings, the brief review of the polarimeter, the principle of the multiparameter measurement and the progress of the research on the multiparameter measurement are explained. The measurement method that the authors have proposed is suitable for the reactor for the following reasons; multiparameters can be obtained from a small numbermore » of diagnostics, the proposed method does not depend on time-history, and far-infrared light utilized by the polarimeter is less sensitive to degradation of of optical components. Taking into account the measuring error, performance assessment of the proposed method was carried. Assuming that the error of Δθ and Δε were 0.1° and 0.6°, respectively, the error of reconstructed j{sub φ}, n{sub e} and T{sub e} were 12 %, 8.4 % and 31 %, respectively. This study has shown that the reconstruction error can be decreased by increasing the number of the wavelength of the probing laser and by increasing the number of the viewing chords. For example, By increasing the number of viewing chords to forty-five, the error of j{sub φ}, n{sub e} and T{sub e} were reduced to 4.4 %, 4.4 %, and 17 %, respectively.« less

  17. Evaluation of the Ration, Cold Weather, by Navy Seals, 1984

    DTIC Science & Technology

    1986-07-01

    Rankings (9 point scale, l=Dislike Extremely, 9=Like Extremely) BREAKFAST Maple and Brown Sugar Oatmeal Apple and Cinnamon Oatmeal ENTREES...EVALUATION: Items should be evaluated for taste, quality, quanti Follow each rating with a supporting statement and comments Apple and Cinnamon ...Oatmeal Maple and Brown Sugar Oatmeal Orange Nut Cake Brownie Orange Beverage Bars Cocoa Tea Chicken Noodle Soup Strawberry Fruit Soup Raspberry

  18. The Effect of G-ORS Along With Rice Soup in the Treatment of Acute Diarrhea in Children: A Single-Blind Randomized Controlled Trial.

    PubMed

    Kianmehr, Mojtaba; Saber, Ashraf; Moshari, Jalil; Ahmadi, Reza; Basiri-Moghadam, Mahdi

    2016-06-01

    The world health organization guidelines for treatment of diarrhea in children emphasize on continued feeding together with prescription of oral rehydration solution (ORS) and supplementary zinc therapy. However, conflicting viewpoints exist regarding the optimal diet and dietary ingredients for children with diarrhea. Moreover, few studies have investigated the effect of rice soup along with ORS in the treatment of this disease. This study aimed to explore effects of simultaneous taking of glucose oral rehydration solution (G-ORS) and rice soup in the treatment of acute diarrhea in 8 to 24-month-old children. This single-blind controlled clinical trial was conducted in the pediatric ward of 22nd of Bahman hospital, Gonabad, Iran between June 2013 and February 2014. Forty children aged 8-24 months with acute diarrhea were randomly assigned into an intervention group (G-ORS plus rice soup group) comprising 20 babies and a control group (G-ORS) of 20 children based on balanced blocking randomization. The variables under investigation were diarrhea duration, patient hospitalization, need for intravenous (IV) fluids and stool output frequency. Data was analyzed using independent samples t and chi-square test. At the end of study, the time for treating acute watery diarrhea in the intervention and control groups were 21.10 ± 8.81 and 34.55 ± 5.82 hours (P < 0.001) and hospital stay were 34.05 ± 6.62 and 40.20 ± 6.32 hours (P = 0.005). Moreover, stool output frequency were 4.20 ± 0.95 and 8.00 ± 1.37 (P < 0.001) in the first 24 hours, and 2.18 ± 0.60 and 2.80 ± 0.76 (P = 0.03) in the second 24 hours of treatment in intervention and control groups, respectively. Rice soup regimen was highly effective and inexpensive in the treatment of acute diarrhea in children. Thus, in addition to the common treatment by G-ORS, rice soup can be consumed simultaneously with G-ORS.

  19. On the possibility of space objects invasion observations into the Earth's atmosphere with the help of a multifunctional polarimeter

    NASA Astrophysics Data System (ADS)

    Nevodovskyi, P. V.; Steklov, A. F.; Vidmachenko, A. P.

    2018-05-01

    Relevance of the tasks associated with the observation of the invasion of space objects into the Earth's atmosphere increases with each passing year. We used astronomical panoramic polarimeter for carrying out of polarimetric observations of objects, that flying into the atmosphere of the Earth from the surrounding outer space.

  20. Panoramic Stokes-polarimeter

    NASA Astrophysics Data System (ADS)

    Syniavskyi, I. I.; Ivanov, Yu. S.; Vidmachenko, A. P.; Karpov, N. V.

    2013-12-01

    This article proposes optical layout of the imaging polarimeter based on the polarization films to measure the linear polarization of point and extended celestial objects. The spectral range of device is 420-850 nm, field of view 0.25°x0.25°. The device is designed to equip the telescope with a diameter of primary mirror about 400 mm and aperture f/12.

  1. PIMACS (Polarimeter and improved modular anti-coincidence system): an effective instrument concept for x-, gamma-ray monitoring, and polarimetry measurements on the International Space Station

    NASA Astrophysics Data System (ADS)

    Stuffler, Timo; Graue, Roland; Bird, Antony J.; Dean, Antony; Staubert, Rüdiger

    2018-04-01

    This paper, "PIMACS (Polarimeter and improved modular anti-coincidence system): an effective instrument concept for x-, gamma-ray monitoring, and polarimetry measurements on the International Space Station," was presented as part of International Conference on Space Optics—ICSO 1997, held in Toulouse, France.

  2. Design and Calibration of the QUIET CMB Polarimeter

    NASA Astrophysics Data System (ADS)

    Buder, Immanuel

    2011-04-01

    QUIET is a large--angular-scale Cosmic Microwave Background (CMB) polarimeter designed to measure the B-mode signal from inflation. The design incorporates a new time-stream "double-demodulation" technique, a 1.4-m Mizuguchi--Dragone telescope, natural sky rotation, and frequent boresight rotation to minimize systematic contamination. The levels of contamination in the inflationary signal are below r=0.1, the best yet achieved by any B-mode polarimeter. Moreover, QUIET is unique among B-mode polarimeters in using a large focal-plane array of miniaturized High--Electron-Mobility Transistor (HEMT) based coherent detectors. These detectors take advantage of a breakthrough in microwave-circuit packaging to achieve a field sensitivity of 69,K√s. QUIET has collected > 10,000,ours of data and recently released results from the first observing season at Q band (43 GHz). Analysis of W-band (95-GHz) data is ongoing. I will describe the Q-band calibration plan which uses a combination of astronomical and artificial sources to convert the raw data into polarization measurements with small and well-understood calibration errors. I will also give a status report on calibration for the upcoming W-band results.

  3. Image processing methods to compensate for IFOV errors in microgrid imaging polarimeters

    NASA Astrophysics Data System (ADS)

    Ratliff, Bradley M.; Boger, James K.; Fetrow, Matthew P.; Tyo, J. Scott; Black, Wiley T.

    2006-05-01

    Long-wave infrared imaging Stokes vector polarimeters are used in many remote sensing applications. Imaging polarimeters require that several measurements be made under optically different conditions in order to estimate the polarization signature at a given scene point. This multiple-measurement requirement introduces error in the signature estimates, and the errors differ depending upon the type of measurement scheme used. Here, we investigate a LWIR linear microgrid polarimeter. This type of instrument consists of a mosaic of micropolarizers at different orientations that are masked directly onto a focal plane array sensor. In this scheme, each polarization measurement is acquired spatially and hence each is made at a different point in the scene. This is a significant source of error, as it violates the requirement that each polarization measurement have the same instantaneous field-of-view (IFOV). In this paper, we first study the amount of error introduced by the IFOV handicap in microgrid instruments. We then proceed to investigate means for mitigating the effects of these errors to improve the quality of polarimetric imagery. In particular, we examine different interpolation schemes and gauge their performance. These studies are completed through the use of both real instrumental and modeled data.

  4. Instrumentation and Future Missions in the Upcoming Era of X-ray Polarimetry

    NASA Astrophysics Data System (ADS)

    Fabiani, Sergio

    2018-05-01

    The maturity of current detectors based on technologies that range from solid state to gases renewed the interest for X-ray polarimetry, raising the enthusiasm of a wide scientific community to improve the performance of polarimeters as well as to produce more detailed theoretical predictions. We will introduce the basic concepts about measuring the polarization of photons, especially in the X-rays, and we will review the current state of the art of polarimeters in a wide energy range from soft~to hard X-rays, from solar flares to distant astrophysical sources. We will introduce relevant examples of polarimeters developed from the recent past up to the panorama of upcoming space missions to show how the recent development of the technology is allowing reopening the observational window of X-ray polarimetry.

  5. Calibration of Passive Microwave Polarimeters that Use Hybrid Coupler-Based Correlators

    NASA Technical Reports Server (NTRS)

    Piepmeier, J. R.

    2003-01-01

    Four calibration algorithms are studied for microwave polarimeters that use hybrid coupler-based correlators: 1) conventional two-look of hot and cold sources, 2) three looks of hot and cold source combinations, 3) two-look with correlated source, and 4) four-look combining methods 2 and 3. The systematic errors are found to depend on the polarimeter component parameters and accuracy of calibration noise temperatures. A case study radiometer in four different remote sensing scenarios was considered in light of these results. Applications for Ocean surface salinity, Ocean surface winds, and soil moisture were found to be sensitive to different systematic errors. Finally, a standard uncertainty analysis was performed on the four-look calibration algorithm, which was found to be most sensitive to the correlated calibration source.

  6. Strategy for Realizing High-Precision VUV Spectro-Polarimeter

    NASA Astrophysics Data System (ADS)

    Ishikawa, R.; Narukage, N.; Kubo, M.; Ishikawa, S.; Kano, R.; Tsuneta, S.

    2014-12-01

    Spectro-polarimetric observations in the vacuum ultraviolet (VUV) range are currently the only means to measure magnetic fields in the upper chromosphere and transition region of the solar atmosphere. The Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) aims to measure linear polarization at the hydrogen Lyman- α line (121.6 nm). This measurement requires a polarization sensitivity better than 0.1 %, which is unprecedented in the VUV range. We here present a strategy with which to realize such high-precision spectro-polarimetry. This involves the optimization of instrument design, testing of optical components, extensive analyses of polarization errors, polarization calibration of the instrument, and calibration with onboard data. We expect that this strategy will aid the development of other advanced high-precision polarimeters in the UV as well as in other wavelength ranges.

  7. Imaging proportional counters for the stellar X-ray polarimeter. [on Soviet Spectrum X-Gamma mission

    NASA Technical Reports Server (NTRS)

    Watkins, R. B., Jr.; Kaaret, P.

    1990-01-01

    The xenon-filled IPCs being developed for the Stellar X-ray Polarimeter are described. The requirements placed on the IPCs by the design of the polarimeter are discussed and results on the performance of prototype counters are presented. The design of a prototype of the IPCs is described. Finally, the performance of the prototype is reported. Due to the extremely low count rates encountered in X-ray polarimetry, efficient background rejection is the most critical parameter of the IPCs. Using a background rejection scheme employing anticoincidence and pulse shape discrimination, a rejection efficiency of 99 percent has been achieved for Co-60-induced events over an energy range of 2 to 15 keV while retaining more than 80 percent of the X-ray efficiency.

  8. Development of land based radar polarimeter processor system

    NASA Technical Reports Server (NTRS)

    Kronke, C. W.; Blanchard, A. J.

    1983-01-01

    The processing subsystem of a land based radar polarimeter was designed and constructed. This subsystem is labeled the remote data acquisition and distribution system (RDADS). The radar polarimeter, an experimental remote sensor, incorporates the RDADS to control all operations of the sensor. The RDADS uses industrial standard components including an 8-bit microprocessor based single board computer, analog input/output boards, a dynamic random access memory board, and power supplis. A high-speed digital electronics board was specially designed and constructed to control range-gating for the radar. A complete system of software programs was developed to operate the RDADS. The software uses a powerful real time, multi-tasking, executive package as an operating system. The hardware and software used in the RDADS are detailed. Future system improvements are recommended.

  9. The development of the imaging polarimeter's polarizer on the basis of the polarizing film

    NASA Astrophysics Data System (ADS)

    Vidmachenko, A. P.; Ivanov, Yu. S.; Syniavskyi, I. I.

    2015-07-01

    Work has begun on the developing of the scientific equipment "Spectrometer polarimeter", which is planned as one of five devices that form part of the Russian-Ukrainian space experiment "Planetary Monitoring". The devices are designed to form images of celestial objects in the focal plane of a planetary telescope (PT-600) and to register spectral and polarimetric information on gas and aerosol composition of the atmospheres of planets and physics and chemical properties of the surface layers of atmosphereless astronomical bodies. A model of a polarizer based on the use of polarizing films has been designed. This model can be used in the spectrometer-polarimeter. The results of the investigation of the polarizer in the spectral range 420-850 nm are given.

  10. Within month variability in use of soup kitchens in New York State. p4.

    PubMed Central

    Thompson, F E; Taren, D L; Andersen, E; Casella, G; Lambert, J K; Campbell, C C; Frongillo, E A; Spicer, D

    1988-01-01

    This paper describes the variation in use of soup kitchens throughout the month using data from the New York State Nutritional Surveillance Program. Excluding November, December, and May, when holiday meals created a different pattern of use, number of meals served in soup kitchens generally increased toward the end of the month, averaging 43 per cent higher for Upstate and 14 per cent higher for New York City in the last week as compared to the first week of the month. The overall increase throughout the month and difference in the magnitude of increase between Upstate and New York City corresponds to the timing of income maintenance benefits distribution. Distribution of most public assistance benefits occurs at the beginning of each month in Upstate, whereas it is staggered in New York City throughout the month. PMID:3421384

  11. Next Generation X-ray Polarimeter

    NASA Astrophysics Data System (ADS)

    Hill-Kittle, Joe

    The emission regions of many types of X-ray sources are small and cannot be spatially resolved without interferometry techniques that haven't yet been developed. In order to understand the emission mechanisms and emission geometry, alternate measurement techniques are required. Most microphysical processes that affect X-rays, including scattering and magnetic emission processes are imprinted as polarization signatures. X-ray polarization also reveals exotic physical processes occurring in regions of very strong gravitational and magnetic fields. Observations of X-ray polarization will provide a measurement of the geometrical distribution of gas and magnetic fields without foreground depolarization that affects longer wavelengths (e.g. Faraday rotation in the radio). Emission from accretion disks has an inclination-dependent polarization. The polarization signature is modified by extreme gravitational forces, which bend light, essentially changing the contribution of each part of the disk to the integrated total intensity seen by distant observers. Because gravity has the largest effect on the innermost parts of the disk (which are the hottest, and thus contributes to more high energy photons), the energy dependent polarization is diagnostic of disk inclination, black hole mass and spin. Increasing the sensitive energy band will make these measurements possible. X-ray polarimetry will also enable the study of the origin of cosmic rays in the universe, the nature of black holes, the role of black holes in the evolution of galaxies, and the interaction of matter with the highest physically possible magnetic fields. These objectives address NASA's strategic interest in the origin, structure, and evolution of the universe. We propose a two-year effort to develop the Next Generation X-ray Polarimeter (NGXP) that will have more than ten times the sensitivity of the current state of the art. NGXP will make possible game changing measurements of classes of astrophysical sources that were previously unobtainable within realistic observation times e.g. Active Galactic Nuclei (AGN). Standard photoelectric X-ray polarimeter designs are both quantum efficiency (QE) limited and challenging to calibrate due to diffusion of electron signal as it drifts through the gas. Drifting negative ions decreases diffusion to the thermal limit thereby decoupling sensitivity from drift distance and enabling larger detector areas that can be at the focus of larger diameter mirrors and single reflection concentrator optics. NITPCs also allow the selection of constituent gasses and pressures to be based on the optimization of modulation and QE rather than diffusion properties. This versatility enables a large improvement in sensitivity without driving cost and with only moderate increase to mass and power of the detector and/or instrument. Furthermore, the energy band of NGXP will be tunable to maximize the science return. Following the efforts of this proposal NGXP will be proposed as sounding rocket experiment and as a candidate instrument for future opportunities. The GSFC polarimeter group has demonstrated NITPCs for several detector concepts. This proposal leverages the previous effort and team expertise with goals to establish the NITPC as the baseline for narrow field observations of faint persistent sources and to improve the technology readiness of associated technologies such as stainless steel gas electron multipliers and finer readout pitch.

  12. Emissions from Simulated Open Burning of Deployed US Military Waste

    DTIC Science & Technology

    2012-03-22

    pasta …. Wet food waste (slop) 13 1.3 1300 Soup, creams,… Oils and greases 2 0.2 200 oil, grease Unopened MREs 1 0.1 100 MREs Opened MRE Inner... pasta …. Wet food waste (slop) 13.61 1.361 1361.3 Soup, creams,… Oils and greases 2.09 0.209 209.4 oil, grease Unopened MREs 1.05 0.105 104.7 MREs

  13. Food Science of Dashi and Umami Taste.

    PubMed

    Ninomiya, Kumiko

    2016-01-01

    Umami is a basic tastes, along with sweet, salty, bitter and sour, which is imparted by glutamate, one of the free amino acids in foods. Since its discovery of umami by a Japanese scientist in 1908, umami is now perceived globally a basic taste. Recent collaboration among chefs and researchers on traditional soup stocks showed a difference in taste profiles of Japanese soup stock 'dashi' and Western style soup stock. The free amino acids profile's in dashi and soup stock showed how Japanese have traditionally adopted a simple umami taste. The exchange of knowledge on cooking methods and diverse types of umami rich foods in different countries displays the blending of the culinary arts, food science and technology for healthy and tasty solutions. Since Japanese cuisine 'WASHOKU' was listed in the 'Intangible Heritage of UNESCO' in 2013, many people in the world now have great interest in Japanese cuisine. One of the unique characteristics of this cuisine is that 'dashi' is an indispensable material for cooking a variety of Japanese dishes. Many chefs from Europe, US and South America have come to Japan to learn Japanese cuisine in the last 10 years, and umami has become recognized as a common taste worldwide. Researchers and culinary professionals have begun to pay attention to the traditional seasonings and condiments rich in glutamate available throughout the world.

  14. Bisphenol a in canned food products from canadian markets.

    PubMed

    Cao, Xu-Liang; Corriveau, Jeannette; Popovic, Svetlana

    2010-06-01

    A method based on solid phase extraction followed by derivatization and gas chromatography-mass spectrometry analysis was validated for the determination of bisphenol A (BPA) in canned food products. This method was used to analyze 78 canned food products for BPA. Concentrations of BPA in canned food products differed considerably among food types, but all were below the specific migration limit of 0.6 mg/kg set by the European Commission Directive for BPA in food or food simulants. Canned tuna products had the highest BPA concentrations in general, with mean and maximum values of 137 and 534 ng/g, respectively. BPA concentrations in the condensed soup products were considerably higher than those in the ready-to-serve soup products, with mean and maximum values of 105 and 189 ng/g, respectively, for the condensed soups and 15 and 34 ng/g, respectively, for the ready-to-serve soups. BPA concentrations in canned vegetable products were relatively low; about 60% of the products had BPA concentrations of less than 10 ng/g. Canned tomato paste products had lower BPA concentrations than did canned pure tomato products. The mean and maximum BPA concentrations were 1.1 and 2.1 ng/g, respectively, for tomato paste products and 9.3 and 23 ng/g, respectively, for the pure tomato products.

  15. Why Were Polysaccharides Necessary?

    NASA Astrophysics Data System (ADS)

    Tolstoguzov, Vladimir

    2004-12-01

    The main idea of this paper is that the primordial soup may be modelled by food systems whose structure-property relationship is based on non-specific interactions between denatured biopolymers. According to the proposed hypothesis, polysaccharides were the first biopolymers that decreased concentration of salts in the primordial soup, `compatibilised' and drove the joint evolution of proto-biopolymers. Synthesis of macromolecules within the polysaccharide-rich medium could have resulted in phase separation of the primordial soup and concentration of the polypeptides and nucleic acids in the dispersed phase particles. The concentration of proto-biopolymer mixtures favoured their cross-linking in hybrid supermacromolecules of conjugates. The cross-linking of proto-biopolymers could occur by hydrophobic, electrostatic interactions, H-bonds due to freezing aqueous mixed biopolymer dispersions and/or by covalent bonds due to the Maillard reaction. Cross-linking could have increased the local concentration of chemically different proto-biopolymers, fixed their relative positions and made their interactions reproducible. Attractive-repulsive interactions between cross-linked proto-biopolymer chains could develop pairing of the monomer units, improved chemical stability (against hydrolysis) and led to their mutual catalytic activity and coding. Conjugates could probably evolve to the first self-reproduced entities and then to specialized cellular organelles. Phase separation of the primordial soup with concentration of conjugates in the dispersed particles has probably resulted in proto-cells.

  16. Linear Combination of Heuristics Approach to Spatial Sampling Hyperspectral Data for Target Tracking

    DTIC Science & Technology

    2010-12-01

    Figure 37 - Illustration of the tunable spectral polarimeter. ........................................... 154 Figure 38 - Illustration of micromirrors ...polarimeter. 9.2 Multiobject Tracking Spectrometer The idea of combining an array of MEMS micromirrors with an imager and a spectrometer array is the... micromirror array is located at an intermediate focal plane of the optical system. If all the individual mirrors are turned in the same direction

  17. The speckle polarimeter of the 2.5-m telescope: Design and calibration

    NASA Astrophysics Data System (ADS)

    Safonov, B. S.; Lysenko, P. A.; Dodin, A. V.

    2017-05-01

    The speckle polarimeter is a facility instrument of the 2.5-mSAIMSU telescope that combines the features of a speckle interferometer and a polarimeter. The speckle polarimeter is designed for observations in several visible bands in the following modes: speckle interferometry, polarimetry, speckle polarimetry, and polaroastrometry. In this paper we describe the instrument design and the procedures for determining the angular scale of the camera and the position angle of the camera and the polarimeter. Our measurements of the parameters for the binary star HD 9165 are used as an example to demonstrate the technique of speckle interferometry. For bright objects the accuracy of astrometry is limited by the error of the correction for the distortion caused by the atmospheric dispersion compensator. At zenith distances less than 45◦ the additional relative measurement error of the separation is 0.7%, while the additional error of the position angle is 0.3°. In the absence of a dispersion compensator the accuracy of astrometry is limited by the uncertainty in the scale and position angle of the camera, which are 0.15% and 0.06°, respectively. We have performed polarimetric measurements of unpolarized stars and polarization standards. The instrumental polarization at the Cassegrain focus in the V band does not exceed 0.01%. The instrumental polarization for the Nasmyth focus varies between 2 and 4% within the visible range; we have constructed its model and give a method for its elimination from the measurements. For stars with an intrinsic polarization of less than 0.2% during observations at the Cassegrain focus the error is determined mainly by the photon and readout noises and can reach 5 × 10-5.

  18. Large size GEM for Super Bigbite Spectrometer (SBS) polarimeter for Hall A 12GeV program at JLab

    DOE PAGES

    Gnanvo, Kondo; Liyanage, Nilanga; Nelyubin, Vladimir; ...

    2015-05-01

    We report on the R&D effort in the design and construction of a large size GEM chamber for the Proton Polarimeter of the Super Bigbite Spectrometer (SBS) in Hall A at Thomas Jefferson National Laboratory (JLab). The SBS Polarimeter trackers consist of two sets of four large chambers of size 200 cm x 60 cm 2. Each chamber is a vertical stack of four GEM modules with an active area of 60 cm x 50 cm. We have built and tested several GEM modules and we describe in this paper the design and construction of the final GEM as wellmore » as the preliminary results on performances from tests carried out in our detector lab and with test beams at (Fermilab).« less

  19. SOUTH POL: Revealing the Polarized Southern Sky

    NASA Astrophysics Data System (ADS)

    Magalhães, A. M.

    2014-10-01

    SOUTH POL will be a survey of the Southern sky in optical polarized light. It will use a newly designed polarimeter for an 80cm Robotic Telescope. Telescope and polarimeter will be installed at CTIO, Chile. The initial goal is to cover the sky south of declination -15° in about two years of observing time, aiming at a polarimetric accuracy ≤ 0.1% down to V=15, with a camera covering a field of about 2.0 square degrees. SOUTH POL will impact areas such as Cosmology, Extragalactic Astronomy, Interstellar Medium of the Galaxy and Magellanic Clouds, Star Formation, Stellar Envelopes, Stellar Explosions and Solar System, among others. The polarimeter is currently being built and its optics and electronics assembled. We will describe the current status of the project. This project is supported by FAPESP. AMM is also supported by CNPq.

  20. Quantitative performance of a polarization diffraction grating polarimeter encoded onto two liquid-crystal-on-silicon displays

    NASA Astrophysics Data System (ADS)

    Cofré, Aarón; Vargas, Asticio; Torres-Ruiz, Fabián A.; Campos, Juan; Lizana, Angel; del Mar Sánchez-López, María; Moreno, Ignacio

    2017-11-01

    We present a quantitative analysis of the performance of a complete snapshot polarimeter based on a polarization diffraction grating (PDGr). The PDGr is generated in a common path polarization interferometer with a Z optical architecture that uses two liquid-crystal on silicon (LCoS) displays to imprint two different phase-only diffraction gratings onto two orthogonal linear states of polarization. As a result, we obtain a programmable PDGr capable to act as a simultaneous polarization state generator (PSG), yielding diffraction orders with different states of polarization. The same system is also shown to operate as a polarization state analyzer (PSA), therefore useful for the realization of a snapshot polarimeter. We analyze its performance using quantitative metrics such as the conditional number, and verify its reliability for the detection of states of polarization.

  1. Earth Observing Scanning Polarimeter (EOSP), phase B

    NASA Technical Reports Server (NTRS)

    1990-01-01

    Evaluations performed during a Phase B study directed towards defining an optimal design for the Earth Observing Scanning Polarimeter (EOSP) instrument is summarized. An overview of the experiment approach is included which provides a summary of the scientific objectives, the background of the measurement approach, and the measurement method. In the instrumentation section, details of the design are discussed starting with the key instrument features required to accomplish the scientific objectives and a system characterization in terms of the Stokes vector/Mueller matrix formalism. This is followed by a detailing of the instrument design concept, the design of the individual elements of the system, the predicted performance, and a summary of appropriate instrument testing and calibration. The selected design makes use of key features of predecessor polarimeters and is fully compatible with the Earth Observing System spacecraft requirements.

  2. Optimal reference polarization states for the calibration of general Stokes polarimeters in the presence of noise

    NASA Astrophysics Data System (ADS)

    Mu, Tingkui; Bao, Donghao; Zhang, Chunmin; Chen, Zeyu; Song, Jionghui

    2018-07-01

    During the calibration of the system matrix of a Stokes polarimeter using reference polarization states (RPSs) and pseudo-inversion estimation method, the measurement intensities are usually noised by the signal-independent additive Gaussian noise or signal-dependent Poisson shot noise, the precision of the estimated system matrix is degraded. In this paper, we present a paradigm for selecting RPSs to improve the precision of the estimated system matrix in the presence of both types of noise. The analytical solution of the precision of the system matrix estimated with the RPSs are derived. Experimental measurements from a general Stokes polarimeter show that accurate system matrix is estimated with the optimal RPSs, which are generated using two rotating quarter-wave plates. The advantage of using optimal RPSs is a reduction in measurement time with high calibration precision.

  3. An upgraded interferometer-polarimeter system for broadband fluctuation measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parke, E., E-mail: eparke@ucla.edu; Ding, W. X.; Brower, D. L.

    2016-11-15

    Measuring high-frequency fluctuations (above tearing mode frequencies) is important for diagnosing instabilities and transport phenomena. The Madison Symmetric Torus interferometer-polarimeter system has been upgraded to utilize improved planar-diode mixer technology. The new mixers reduce phase noise and allow more sensitive measurements of fluctuations at high frequency. Typical polarimeter rms phase noise values of 0.05°–0.07° are obtained with 400 kHz bandwidth. The low phase noise enables the resolution of fluctuations up to 250 kHz for polarimetry and 600 kHz for interferometry. The importance of probe beam alignment for polarimetry is also verified; previously reported tolerances of ≤0.1 mm displacement for equilibriummore » and tearing mode measurements minimize contamination due to spatial misalignment to within acceptable levels for chords near the magnetic axis.« less

  4. Study Techniques for Controlling Flavor Intensity in Compressed Foods (Phase 2)

    DTIC Science & Technology

    1976-06-10

    and gravies were prepared as cooked materials, freeze- dried and chopped . The mushroom soup ingredients were all used as procured in their dry...This material, after blending with the soup base, was free£e= dried and chopped prior to blending with the re- maining components in preparation of...Exec- utive Chef, using the following formula: TABLE XII Onion Gravy Formula Ingredients % Onions, Chopped Tomato Paste Hard Wheat Flour Beef

  5. Pressure-assisted thermal sterilization of soup

    NASA Astrophysics Data System (ADS)

    Shibeshi, Kidane; Farid, Mohammed M.

    2010-12-01

    The overall efficiency of an existing scale-up pressure-assisted thermal sterilization (PATS) unit was investigated with regards to inactivation of Geobacillus stearothermophilus spores suspended in pumpkin soup. The PATS unit is a double pipe heat exchanger in which the soup is pumped into its inner high pressure tube and constrained by two high pressure valves, while steam is continuously passed through the annular region to heat the content. The technology is based on pressure generation by thermal expansion of the liquid in an enclosure. In this work, the addition of an air line to push the treated liquid food out of the existing PATS unit has improved the overall quality of the treated samples, as evidenced by achieving higher log reduction of the spores. Compared with thermal processing, the application of PATS shows the potential for lowering the thermal treatment temperature, offering improved food quality.

  6. A Cohort Mortality Study of Workers in a Second Soup Manufacturing Plant.

    PubMed

    Faramawi, Mohammed F; Ndetan, Harrison; Jadhav, Supriya; Johnson, Eric S

    2015-01-01

    The authors previously reported on mortality among workers in a Baltimore soup plant. Increased mortality was observed for cancers of the floor of the mouth, rectosigmoid colon/rectum/anus, epilepsy, and chronic nephritis. Here, the authors report on mortality on a second soup plant in the same locality. Excess mortality was similarly recorded for cancers of the tonsils/oropharynx, rectosigmoid colon/rectum/anus, and lung and myelofibrosis. Excess risk from cardiovascular, cerebrovascular, kidney, and infectious diseases was also observed. These 2 studies are important because firstly, to the authors' knowledge, they are the only reports of mortality in this occupational group in spite of their having a potential for exposure to hazardous carcinogenic agents. Secondly, there is no information on any exposure assessment in this industry. These 2 reports will draw attention to the need to conduct more detailed exposure and mortality investigations in this little-studied group.

  7. Preference of Food Saltiness and Willingness to Consume Low-Sodium Content Food in a Chinese Population.

    PubMed

    Chau, P H; Ngai, H H Y; Leung, A Y M; Li, S F; Yeung, L O Y; Tan-Un, K C

    2017-01-01

    To compare the preference of food saltiness and the willingness to consume low-sodium food among hypertensive older people, non-hypertensive older people and non-hypertensive young people in a Chinese population. A cross-sectional study based on a quota sample. Three saltiness options (low-sodium, medium-sodium and high-sodium) of soup and bread were offered to each participant who rated the taste of each food on a 5-point Likert scale. Then, the participants rated their willingness to consume the low-sodium content foods on a 5-point Likert scale, given they were informed of the benefit of the low-sodium option. Generalised linear mixed model and multiple linear regression were used to analyse the data. Elderly centres and community centres in Hong Kong. Sixty hypertensive older people, 49 non-hypertensive older people and 60 non-hypertensive young people were recruited from June to August 2014. The tastiness score and the willingness score were the primary outcome measures. The Chinese Health Literacy Scale for Low Salt Consumption - Hong Kong population (CHLSalt-HK) was also assessed. The tastiness rating of the high-sodium option of soup was significantly lower than the medium-sodium option (p<0.001), but there was no significant difference between the low-sodium and the medium-sodium options (p=0.204). For bread, tastiness rating of the low-sodium option and the high-sodium option were significantly lower than the medium-sodium option (p<0.001 for both options). The tastiness score of soup did not have significant difference across the groups (p=0.181), but that of bread from the hypertensive older adults (p=0.012) and the non-hypertensive older adults (p=0.006) was significantly higher than the non-hypertensive young adults. Higher willingness rating to consume the low-sodium option was significantly (p<0.001) associated with higher tastiness rating of the low-sodium option of soup and bread, and weakly associated with higher health literacy of low salt intake (soup: p=0.041; bread: p=0.024). Hypertensive older adults tended to be more willing to consume the low-sodium option than non-hypertensive older adults for soup (p=0.009), there was insignificant difference between non-hypertensive older adults and non-hypertensive young adults (p=0.156). For bread, there was insignificant difference in willingness rating to consume low-sodium option (p=0.375). Older people are at a higher risk of hypertension, reduction of salt intake is important for them to reduce their risk of cardiovascular diseases. There is room for reducing the sodium content of soup, while the sodium in bread should be reduced progressively. Improving the taste of low-sodium food may help to promote reduction in dietary sodium intake.

  8. Polarization Techniques for Mitigation of Low Grazing Angle Sea Clutter

    DTIC Science & Technology

    2017-01-01

    Lincoln Laboratory funded an experimental data collection using a fully polarimetic X-band radar assembled largely from COTS components. The Point de Chene...applications and environments in which experimental polarimet- ric radar has proven invaluable. Most notably, the imaging and mapping applications of synthetic...polarimetric analysis, as discussed in Chapter 1. Another part is due to the experimental SAR community’s collective recognition of polarimetry’s value

  9. Developments of a multi-wavelength spectro-polarimeter on the Domeless Solar Telescope at Hida Observatory

    NASA Astrophysics Data System (ADS)

    Anan, Tetsu; Huang, Yu-Wei; Nakatani, Yoshikazu; Ichimoto, Kiyoshi; UeNo, Satoru; Kimura, Goichi; Ninomiya, Shota; Okada, Sanetaka; Kaneda, Naoki

    2018-05-01

    To obtain full Stokes spectra in multi-wavelength windows simultaneously, we developed a new spectro-polarimeter on the Domeless Solar Telescope at Hida Observatory. The new polarimeter consists of a 60 cm aperture vacuum telescope on an altazimuth mounting, an image rotator, a high-dispersion spectrograph, and a polarization modulator and an analyzer composed of a continuously rotating waveplate with a retardation that is nearly constant at around 127° in 500-1100 nm. There are also a polarizing beam splitter located close behind the focus of the telescope, fast and large format CMOS cameras, and an infrared camera. A slit spectrograph allows us to obtain spectra in as many wavelength windows as the number of cameras. We characterized the instrumental polarization of the entire system and established a polarization calibration procedure. The cross-talks among the Stokes Q, U, and V have been evaluated to be about 0.06%-1.2%, depending on the degree of the intrinsic polarizations. In a typical observing setup, a sensitivity of 0.03% can be achieved in 20-60 seconds for 500-1100 nm. The new polarimeter is expected to provide a powerful tool for diagnosing the 3D magnetic field and other vector physical quantities in the solar atmosphere.

  10. Fast Solar Polarimeter: First Light Results

    NASA Astrophysics Data System (ADS)

    Krishnappa, N.; Feller, A.; Iglesia, F. A.; Solanki, S.

    2013-12-01

    Accurate measurements of magnetic fields on the Sun are crucial to understand various physical processes that take place in the solar atmosphere such as solar eruptions, coronal heating, solar wind acceleration, etc. The Fast Solar Polarimeter (FSP) is a new instrument that is being developed to probe magnetic fields on the Sun. One of the main goals of this polarimeter is to carry out high precision spectropolarimetric observations with spatial resolution close to the telescope diffraction limit. The polarimeter is based on pnCCD technology with split frame transfer and simultaneous multi-channel readout, resulting in frame rate upto 1 kHz. The FSP prototype instrument uses a small format pnCCD of 264x264 pixels which has been developed by PNSensor and by the semiconductor lab of the Max Planck Society. The polarization modulator is based on two ferro-electric liquid crystals (FLCs) interlaced between two static retarders. The first solar observations have been carried out with this prototype during May-June, 2013 at German Vacuum Tower Telescope (VTT) on Tenerife, Canary Islands, Spain. Here we present the instrument performance assessments and the first results on the magnetic field measurements. Further, we briefly discuss about the next phase of FSP which will be a dual beam system with 1k x 1k CCDs.

  11. An integrated thermo-structural model to design a polarimeter for the GTC

    NASA Astrophysics Data System (ADS)

    Di Varano, I.; Strassmeier, K. G.; Woche, M.; Laux, U.

    2016-07-01

    The GTC (Gran Telescopio Canarias), with an equivalent aperture of 10.4 m, effective focal length of 169.9 m, located at the Observatorio del Roque de los Muchachos , in La Palma, Canary Islands, will host on its Cassegrain focus the GRAPE polarimeter (GRAntecan PolarimEter). At such focus the plate scale is 1.21 arcsec/mm and the unvignetted FOV 8 arcmin. The instrument will provide full Stokes polarimetry in the spectral range 380-1500 nm, feeding simultaneously up to two spectrographs. At the moment an interface to HORS (High Optical Resolution Spectrograph) is being defined, located on the Nasmyth platform, it has a FWHM resolving power of about 25,000 (5 pixel) within a spectral range of 400-680 nm. The rotator and instrumental flanges for the Cassegrain focus are currently under definition. Hereafter I present the state of art of the mechanical design of the polarimeter, whose strategy is based on an integrated model of Zemax design into ANSYS FEM static and dynamic analyses with thermal loads applied, in order to retrieve tip-tilt, decentering errors and other significant parameters to be looped back to the Zemax model. In such a way it is possible to compare and refine the results achieved through the tolerance analysis.

  12. Imaging Spectropolarimeter for the Multi-Application Solar Telescope at Udaipur Solar Observatory: Characterization of Polarimeter and Preliminary Observations

    NASA Astrophysics Data System (ADS)

    Tiwary, Alok Ranjan; Mathew, Shibu K.; Bayanna, A. Raja; Venkatakrishnan, P.; Yadav, Rahul

    2017-04-01

    The Multi-Application Solar Telescope (MAST) is a 50 cm off-axis Gregorian telescope that has recently become operational at the Udaipur Solar Observatory (USO). An imaging spectropolarimeter is being developed as one of the back-end instruments of MAST to gain a better understanding of the evolution and dynamics of solar magnetic and velocity fields. This system consists of a narrow-band filter and a polarimeter. The polarimeter includes a linear polarizer and two sets of liquid crystal variable retarders (LCVRs). The instrument is intended for simultaneous observations in the spectral lines 6173 Å and 8542 Å, which are formed in the photosphere and chromosphere, respectively. In this article, we present results from the characterization of the LCVRs for the spectral lines of interest and the response matrix of the polarimeter. We also present preliminary observations of an active region obtained using the spectropolarimeter. For verification purposes, we compare the Stokes observations of the active region obtained from the Helioseismic Magnetic Imager (HMI) onboard the Solar Dynamics Observatory (SDO) with that of MAST observations in the spectral line 6173 Å. We find good agreement between the two observations, considering the fact that MAST observations are limited by seeing.

  13. GEMS X-ray Polarimeter Performance Simulations

    NASA Technical Reports Server (NTRS)

    Baumgartner, Wayne H.; Strohmayer, Tod; Kallman, Tim; Black, J. Kevin; Hill, Joanne; Swank, Jean

    2012-01-01

    The Gravity and Extreme Magnetism Small explorer (GEMS) is an X-ray polarization telescope selected as a NASA small explorer satellite mission. The X-ray Polarimeter on GEMS uses a Time Projection Chamber gas proportional counter to measure the polarization of astrophysical X-rays in the 2-10 keV band by sensing the direction of the track of the primary photoelectron excited by the incident X-ray. We have simulated the expected sensitivity of the polarimeter to polarized X-rays. We use the simulation package Penelope to model the physics of the interaction of the initial photoelectron with the detector gas and to determine the distribution of charge deposited in the detector volume. We then model the charge diffusion in the detector,and produce simulated track images. Within the track reconstruction algorithm we apply cuts on the track shape and focus on the initial photoelectron direction in order to maximize the overall sensitivity of the instrument, using this technique we have predicted instrument modulation factors nu(sub 100) for 100% polarized X-rays ranging from 10% to over 60% across the 2-10 keV X-ray band. We also discuss the simulation program used to develop and model some of the algorithms used for triggering, and energy measurement of events in the polarimeter.

  14. Design and Fabrication of the All-Reflecting H-Lyman alpha Coronagraph/Polarimeter

    NASA Technical Reports Server (NTRS)

    Hoover, Richard B.; Johnson, R. Barry; Fineschi, Silvano; Walker, Arthur B. C., Jr.; Baker, Phillip C.; Zukic , Muamer; Kim, Jongmin

    1993-01-01

    We have designed, analyzed, and are now fabricating an All-Reflecting H-Lyman alpha Coronagraph/Polarimeter for solar research. This new instrument operates in a narrow bandpass centered at lambda 1215.7 A-the neutral hydrogen Lyman alpha (Ly-alpha) line. It is shorter and faster than the telescope which produced solar Ly-alpha images as a part of the MSSTA payload that was launched on May 13, 1991. The Ly-alpha line is produced and linearly polarized in the solar corona by resonance scattering, and the presence of a magnetic field modifies this polarization according to the Hanle effect. The Lyman alpha Coronagraph/Polarimeter instrument has been designed to measure coronal magnetic fields by interpreting, via the Hanle effect, the measured linear polarization of the coronal Ly-alpha line. Ultrasmooth mirrors, polarizers, and filters are being flow-polished for this instrument from CVD silicon carbide substrates. These optical components will be coated using advanced induced transmission and absorption thin film multilayer coatings, to optimize the reflectivity and polarization properties at 1215.7 A. We describe some of the solar imaging results obtained with the MSSTA Lyman alpha coronagraph. We also discuss the optical design parameters and fabrication plans for the All-Reflecting H-Lyman alpha Coronagraph/Polarimeter.

  15. Transforming Our Understanding of the X-ray Universe: The Imaging X-ray Polarimeter Explorer (IXPE)

    NASA Technical Reports Server (NTRS)

    Weisskopf, Martin C.; Bellazzini, Ronaldo; Costa, Enrico; Matt, Giorgio; Marshall, Herman; ODell, Stephen L.; Pavlov, George; Ramsey, Brian; Romani, Roger

    2014-01-01

    Accurate X-ray polarimetry can provide unique information on high-energy-astrophysical processes and sources. As there have been no meaningful X-ray polarization measurements of cosmic sources since our pioneering work in the 1970's, the time is ripe to explore this new parameter space in X-ray astronomy. To accomplish this requires a well-calibrated and well understood system that-particularly for an Explorer mission-has technical, cost, and schedule credibility. The system that we shall present satisfies these conditions, being based upon completely calibrated imaging- and polarization-sensitive detectors and proven X-ray-telescope technology.

  16. Sounding Rocket Instrument Development at UAHuntsville/NASA MSFC

    NASA Technical Reports Server (NTRS)

    Kobayashi, Ken; Cirtain, Jonathan; Winebarger, Amy; Savage, Sabrina; Golub, Leon; Korreck, Kelly; Kuzin, Sergei; Walsh, Robert; DeForest, Craig; DePontieu, Bart; hide

    2013-01-01

    We present an overview of solar sounding rocket instruments developed jointly by NASA Marshall Space Flight Center and the University of Alabama in Huntsville. The High Resolution Coronal Imager (Hi-C) is an EUV (19.3 nm) imaging telescope which was flown successfully in July 2012. The Chromospheric Lyman-Alpha SpectroPolarimeter (CLASP) is a Lyman Alpha (121.6 nm) spectropolarimeter developed jointly with the National Astronomical Observatory of Japan and scheduled for launch in 2015. The Marshall Grazing Incidence X-ray Spectrograph is a soft X-ray (0.5-1.2 keV) stigmatic spectrograph designed to achieve 5 arcsecond spatial resolution along the slit.

  17. Hydro-gravitational-dynamics cosmology is crucial to astrobiology and the biological big bang at two million years

    NASA Astrophysics Data System (ADS)

    Gibson, Carl H.

    2015-09-01

    Hydro-Gravitational-Dynamics (HGD) cosmology predicts that the 1012 s (30 Kyr) H-He4 plasma protogalaxies become, by viscous fragmentation, proto-globular-star-cluster PGC clumps of a trillion small planets, at the 1013 s transition to gas. Larger planets and stars result from mergers of these hot 3000 K hydrogen planets in the PGCs. Stardust oxides of life chemicals C, N, O, Fe, Si seed the planets when the stars explode as supernovae. Hydrogen reduces the metal oxides and silicates to metal and rocky planet cores with massive hot water oceans at critical water temperature 647 K in which organic chemistry and life can develop. Because information is continually exchanged between the merging planets, they form a cosmic soup. The biological big bang occurs between 2 Myr when liquid water rains hot deep oceans in the cooling cosmos, and 8 Myr when the oceans freeze6. Thus, HGD cosmology explains the Hoyle/Wickramasinghe concept of cometary panspermia by giving a vast, hot, nourishing, cosmological primordial soup for abiogenesis, and the means for transmitting the resulting life forms and their evolving RNA/DNA mechanisms widely throughout the universe. A primordial astrophysical basis is provided for astrobiology by HGD cosmology. Concordance ΛCDMHC cosmology is rendered obsolete by the observation of complex life on Earth.

  18. Use of Consumer Acceptability as a Tool to Determine the Level of Sodium Reduction: A Case Study on Beef Soup Substituted With Potassium Chloride and Soy-Sauce Odor.

    PubMed

    Lee, Cho Long; Lee, Soh Min; Kim, Kwang-Ok

    2015-11-01

    In this study, consumer acceptability was considered as a tool of reducing sodium rather than just using it as a final examination of the successfulness of the substitution. This study consisted of 4 experimental steps. First, by gradually reducing the concentrations of NaCl, consumer rejection threshold (CRT) of NaCl in beef soup was examined. Then, the amount of KCl that can increase preference was examined in 2 low sodium beef soups, with sodium concentrations slightly above or below the CRT. Relative saltiness of various KCl and NaCl/KCl mixtures were also measured. Finally, consumers evaluated acceptability and intensities of sensory characteristics for 9 beef soup samples that differed with respect to NaCl content and/or KCl content with/without addition of salty-congruent odor (soy-sauce odor). The results showed that in the "above CRT" system, consumer acceptability as well as sensory profile of low sodium beef soup substituted using KCl had similar profile to the control although saltiness was not fully recovered, whereas in the "below CRT" system, consumer acceptability was not recovered using KCl solely as a substitute. Potential of using salty-congruent odor as a final touch to induce salty taste was observed; however, the results inferred the importance of having almost no artificialness in the odor and having harmony with the final product when using it as a strategy to substitute sodium. Overall, the results of the study implied the importance of considering consumer acceptability when approaching sodium reduction to better understand the potentials of the sodium substitutes and salty-congruent odor. Strategies attempting to reduce sodium contents in food have mainly substituted sodium to the level that provides equivalent salty taste and then examined consumer liking. However, these approaches may result in failure for consumer appeal. This study attempted to consider consumer acceptability as a tool of reducing sodium in beef soup substituted using potassium chloride and salty-congruent odor. The result showed that considering consumer acceptability during sodium reduction enabled to better understand the potentials of the sodium substitutes and salty-congruent odor. © 2015 Institute of Food Technologists®

  19. Dietary Seawood and Early Breast Cancer: A Randomized Trial

    DTIC Science & Technology

    2007-05-01

    after 9 years of follow-up, that high intake of miso (a seaweed-rich broth flavored with fermented soybean paste) soup was the food most closely...reported after 9 years of follow-up, that high intake of miso ( fermented soybean paste) soup was the food most closely associated with the lowest breast...Ke, Y.F. Liang, and T. Higa. 2002. Assessment of the ability of the antioxidant cocktail-derived from fermentation of plants with effective

  20. "Submesoscale Soup" Vorticity and Tracer Statistics During the Lateral Mixing Experiment

    NASA Astrophysics Data System (ADS)

    Shcherbina, A.; D'Asaro, E. A.; Lee, C. M.; Molemaker, J.; McWilliams, J. C.

    2012-12-01

    A detailed view of upper-ocean velocity, vorticity, and tracer statistics was obtained by a unique synchronized two-vessel survey in the North Atlantic in winter 2012. In winter, North Atlantic Mode water region south of the Gulf Stream is filled with an energetic, homogeneous, and well-developed submesoscale turbulence field - the "submesoscale soup". Turbulence in the soup is produced by frontogenesis and the surface layer instability of mesoscale eddy flows in the vicinity of the Gulf Stream. This region is a convenient representation of the inertial range of the geophysical turbulence forward cascade spanning scales of o(1-100km). During the Lateral Mixing Experiment in February-March 2012, R/Vs Atlantis and Knorr were run on parallel tracks 1 km apart for 500 km in the submesoscale soup region. Synchronous ADCP sampling provided the first in-situ estimates of full 3-D vorticity and divergence without the usual mix of spatial and temporal aliasing. Tracer distributions were also simultaneously sampled by both vessels using the underway and towed instrumentation. Observed vorticity distribution in the mixed layer was markedly asymmetric, with sparse strands of strong anticyclonic vorticity embedded in a weak, predominantly cyclonic background. While the mean vorticity was close to zero, distribution skewness exceeded 2. These observations confirm theoretical and numerical model predictions for an active submesoscale turbulence field. Submesoscale vorticity spectra also agreed well with the model prediction.

  1. Impact of essential oils on the taste acceptance of tomato juice, vegetable soup, or poultry burgers.

    PubMed

    Espina, Laura; García-Gonzalo, Diego; Pagán, Rafael

    2014-08-01

    Despite the vast body of available literature on the possibilities of essential oils (EOs) as food preservatives or functional ingredients, the sensory impact of their addition to foods has barely been approached. This work focuses on the hedonic taste acceptance of 3 food products (tomato juice, vegetable soup, and poultry burgers) when they are incorporated with potentially antimicrobial concentrations (20 to 200 μL/L) of 6 selected EOs (lemon, pennyroyal mint, thyme, and rosemary) and individual compounds (carvacrol, p-cymene). Although addition of 20 μL/L of pennyroyal mint or lemon EO did not change the taste acceptance of tomato juice, higher concentrations of these compounds or any concentration of the other 4 compounds did. In vegetable soup, the tolerance limit for rosemary EO, thyme EO, carvacrol, or p-cymene was 20 μL/L, while the addition of 200 μL/L of lemon EO was accepted. Tolerance limits in poultry burgers were established in 20 μL/L for carvacrol and thyme EOs, 100 μL/L for pennyroyal mint EO and p-cymene, and 200 μL/L for lemon and rosemary EOs. Moreover, incorporation of pennyroyal mint EO to tomato juice or poultry burgers, and enrichment of vegetable soup with lemon EO, could contribute to the development of food products with an improved sensory appeal. © 2014 Institute of Food Technologists®

  2. Salt taste after bariatric surgery and weight loss in obese persons

    PubMed Central

    Maedge, Julia; Lam, Linda; Blasche, Gerhard; Shakeri-Leidenmühler, Soheila; Kundi, Michael; Ludvik, Bernhard; Langer, Felix B.; Prager, Gerhard; Schindler, Karin; Dürrschmid, Klaus

    2016-01-01

    Background. Little is known about the perception of salty taste in obese patients, especially after bariatric surgery. Therefore, the aim of this study was to analyse possible differences in salt detection thresholds and preferences for foods differing in salt content in obese persons before and after bariatric surgery with weight loss compared to non-obese individuals. Methods. Sodium chloride detection thresholds and liking for cream soups with different salt concentrations were studied with established tests. Moreover, a brief salt food questionnaire was assessed to identify the usage and awareness of salt in food. Results. The results showed similar mean sodium chloride detection thresholds between non-obese and obese participants. After bariatric surgery a non-significant increase in the salt detection threshold was observed in the obese patients (mean ± SD: 0.44 ± 0.24 g NaCl/L before OP vs. 0.64 ± 0.47 g NaCl/L after OP, p = 0.069). Cream soup liking between controls and obese patients were not significantly different. However, significant sex specific differences were detected with the tested women not liking the soups (p < 0.001). Results from the food questionnaire were similar between the groups. Conclusion. No differences between non-obese persons and obese patients were shown regarding the salt detection threshold. However, due to highly significant differences in soup liking, sex should be taken into consideration when conducting similar sensory studies. PMID:27330856

  3. [Therapeutic effect of double fill nine tastes soup in treating recurrent respiratory infection (RRI) and change of immune function in children].

    PubMed

    Wang, Youcheng; Zhang, Lijuan; Hu, Guohua; Wang, Menghe; Tang, Xiaoyuan; Guo, Hui; Shi, Yimei; Chen, Shufang; Shi, Changchun

    2012-04-01

    To investigate the therapeutic effect of double fill nine tastes soup in treating children recurrent respiratory infection (RRTI) and the change of immune function. 77 RRTI patients were randomly selected into observation and control groups. The observation group was treated with Chinese medicine- double fill nine tastes soup,water frying points 2 times oral. The control was treated with transfer factor oral liquid,every 10 mL,2 times daily oral. Treatment periods were both two months. IgA, IgG, IgM and IL-12, TNF-alpha, INF-gamma were detected before and after treatment to assess the clinical effects and the changes of immune factors, meanwhile, a health group was established. Before treatment, compared with the health group, the serum IgA, IgG, IgM, IgE, IL-12, TNF-alpha, IFN-gamma in both groups were significantly different (P < 0.01). After treatment, the ratio of IgA, IgG, Ig M, IL-12, TNF-alpha, IFN-gamma in two groups were significantly different (P < 0.01). Compared with the recurrence rate and clinical effects, the observation group was better than control, and the differences were significant (P < 0.01). Double fill nine tastes soup has significant effects in treating recurrent respiratory infection (RRI) and enhance the immune function in children.

  4. Objective and quantitative definitions of modified food textures based on sensory and rheological methodology.

    PubMed

    Wendin, Karin; Ekman, Susanne; Bülow, Margareta; Ekberg, Olle; Johansson, Daniel; Rothenberg, Elisabet; Stading, Mats

    2010-06-28

    Patients who suffer from chewing and swallowing disorders, i.e. dysphagia, may have difficulties ingesting normal food and liquids. In these patients a texture modified diet may enable that the patient maintain adequate nutrition. However, there is no generally accepted definition of 'texture' that includes measurements describing different food textures. Objectively define and quantify categories of texture-modified food by conducting rheological measurements and sensory analyses. A further objective was to facilitate the communication and recommendations of appropriate food textures for patients with dysphagia. About 15 food samples varying in texture qualities were characterized by descriptive sensory and rheological measurements. Soups were perceived as homogenous; thickened soups were perceived as being easier to swallow, more melting and creamy compared with soups without thickener. Viscosity differed between the two types of soups. Texture descriptors for pâtés were characterized by high chewing resistance, firmness, and having larger particles compared with timbales and jellied products. Jellied products were perceived as wobbly, creamy, and easier to swallow. Concerning the rheological measurements, all solid products were more elastic than viscous (G'>G''), belonging to different G' intervals: jellied products (low G') and timbales together with pâtés (higher G'). By combining sensory and rheological measurements, a system of objective, quantitative, and well-defined food textures was developed that characterizes the different texture categories.

  5. Objective and quantitative definitions of modified food textures based on sensory and rheological methodology

    PubMed Central

    Wendin, Karin; Ekman, Susanne; Bülow, Margareta; Ekberg, Olle; Johansson, Daniel; Rothenberg, Elisabet; Stading, Mats

    2010-01-01

    Introduction Patients who suffer from chewing and swallowing disorders, i.e. dysphagia, may have difficulties ingesting normal food and liquids. In these patients a texture modified diet may enable that the patient maintain adequate nutrition. However, there is no generally accepted definition of ‘texture’ that includes measurements describing different food textures. Objective Objectively define and quantify categories of texture-modified food by conducting rheological measurements and sensory analyses. A further objective was to facilitate the communication and recommendations of appropriate food textures for patients with dysphagia. Design About 15 food samples varying in texture qualities were characterized by descriptive sensory and rheological measurements. Results Soups were perceived as homogenous; thickened soups were perceived as being easier to swallow, more melting and creamy compared with soups without thickener. Viscosity differed between the two types of soups. Texture descriptors for pâtés were characterized by high chewing resistance, firmness, and having larger particles compared with timbales and jellied products. Jellied products were perceived as wobbly, creamy, and easier to swallow. Concerning the rheological measurements, all solid products were more elastic than viscous (G′>G″), belonging to different G′ intervals: jellied products (low G′) and timbales together with pâtés (higher G′). Conclusion By combining sensory and rheological measurements, a system of objective, quantitative, and well-defined food textures was developed that characterizes the different texture categories. PMID:20592965

  6. Development of an infrared polarimeter

    NASA Technical Reports Server (NTRS)

    Coffeen, D. L.

    1972-01-01

    AEROPOL infrared polarimeter was built for measurements microns between 1.1 and 3.5 microns, with a 1.5 degree field of view, using a wire grid polarization analyzer. A PbS detector is cooled by condensed Freon-13. The instrument operates under minicomputer control, giving a polarization least squares solution each 2.5 seconds. AEROPOL was flown on the NASA CV-990 aircraft, in a remote-sensing study of terrestrial cloud particle sizes and shapes.

  7. The polarization phase difference of orchard trees

    NASA Technical Reports Server (NTRS)

    Wang, James R.; Mo, Tsan

    1990-01-01

    An image obtained by the Jet Propulsion Laboratory's airborne L-band polarimeter (SAR) over an agricultural area near Fresno, California, was analyzed for the signatures of polarization phase difference (PPD). The PPD of orchard trees was found to be distinctly different from that of bare fields or fields covered with other crops. Thus the PPD signatures obtained from a polarimeter may be useful in the understanding of the radar remote sensing of the earth's surface.

  8. Non-uniformity calibration for MWIR polarization imagery obtained with integrated microgrid polarimeters

    NASA Astrophysics Data System (ADS)

    Liu, Hai-Zheng; Shi, Ze-Lin; Feng, Bin; Hui, Bin; Zhao, Yao-Hong

    2016-03-01

    Integrating microgrid polarimeters on focal plane array (FPA) of an infrared detector causes non-uniformity of polarization response. In order to reduce the effect of polarization non-uniformity, this paper constructs an experimental setup for capturing raw flat-field images and proposes a procedure for acquiring non-uniform calibration (NUC) matrix and calibrating raw polarization images. The proposed procedure takes the incident radiation as a polarization vector and offers a calibration matrix for each pixel. Both our matrix calibration and two-point calibration are applied to our mid-wavelength infrared (MWIR) polarization imaging system with integrated microgrid polarimeters. Compared with two point calibration, our matrix calibration reduces non-uniformity by 30 40% under condition of flat-field data test with polarization. The ourdoor scene observation experiment indicates that our calibration can effectively reduce polarization non-uniformity and improve the image quality of our MWIR polarization imaging system.

  9. Chromospheric LAyer SpectroPolarimeter (CLASP2)

    NASA Technical Reports Server (NTRS)

    Narukage, Noriyuki; Cirtain, Jonathan W.; Ishikawa, Ryoko; Trujillo-Bueno, Javier; De Pontieu, Bart; Kubo, Masahito; Ishikawa, Shinnosuke; Kano, Ryohei; Suematsu, Yoshinori; Yoshida, Masaki; hide

    2016-01-01

    The sounding rocket Chromospheric Lyman-Alpha SpectroPolarimeter (CLASP) was launched on September 3rd, 2015, and successfully detected (with a polarization accuracy of 0.1 %) the linear polarization signals (Stokes Q and U) that scattering processes were predicted to produce in the hydrogen Lyman-alpha line (Ly; 121.567 nm). Via the Hanle effect, this unique data set may provide novel information about the magnetic structure and energetics in the upper solar chromosphere. The CLASP instrument was safely recovered without any damage and we have recently proposed to dedicate its second ight to observe the four Stokes profiles in the spectral region of the Mg II h and k lines around 280 nm; in these lines the polarization signals result from scattering processes and the Hanle and Zeeman effects. Here we describe the modifications needed to develop this new instrument called the "Chromospheric LAyer SpectroPolarimeter" (CLASP2).

  10. Analysis of Data from the Balloon Borne Gamma RAy Polarimeter Experiment (GRAPE)

    NASA Astrophysics Data System (ADS)

    Wasti, Sambid K.; Bloser, Peter F.; Legere, Jason S.; McConnell, Mark L.; Ryan, James M.

    2016-04-01

    The Gamma Ray Polarimeter Experiment (GRAPE), a balloon borne polarimeter for 50~300 keV gamma rays, successfully flew in 2011 and 2014. The main goal of these balloon flights was to measure the gamma ray polarization of the Crab Nebula. Analysis of data from the first two balloon flights of GRAPE has been challenging due to significant changes in the background level during each flight. We have developed a technique based on the Principle Component Analysis (PCA) to estimate the background for the Crab observation. We found that the background depended mostly on the atmospheric depth, pointing zenith angle and instrument temperatures. Incorporating Anti-coincidence shield data (which served as a surrogate for the background) was also found to improve the analysis. Here, we present the calibration data and describe the analysis done on the GRAPE 2014 flight data.

  11. Low cost ellipsometer using a standard commercial polarimeter

    NASA Astrophysics Data System (ADS)

    Velosa, F.; Abreu, M.

    2017-08-01

    Ellipsometry is an optical technique to characterize materials or phenomena that occurs at an interface or thin film between two different media. In this paper, we present an experimental low-cost version of a photometric ellipsometer, assembled with commonly found material at every Optics laboratory. The polarization parameters measurement was performed using a Thorlabs PAX5710 polarimeter. The uncertainty computed using the Guide to the Expression of Uncertainty in Measurement (GUM) procedures. With the assembled ellipsometer we were able to measure the thickness of a 10 nm thick SiO2 thin film deposited upon Si, and the complex refractive index of Gold and Tantalum samples. The SiO2 thickness we achieved had an experimental deviation of 4.5% with 2.00 nm uncertainty. The value complex refractive index of Gold and Tantalum measured agrees with the different values found in several references. The uncertainty values were found to be mostly limited by the polarimeter's uncertainty.

  12. A novel comparison of Møller and Compton electron-beam polarimeters

    DOE PAGES

    Magee, J. A.; Narayan, A.; Jones, D.; ...

    2017-01-19

    We have performed a novel comparison between electron-beam polarimeters based on Moller and Compton scattering. A sequence of electron-beam polarization measurements were performed at low beam currents (more » $<$ 5 $$\\mu$$A) during the $$Q_{\\rm weak}$$ experiment in Hall C at Jefferson Lab. These low current measurements were bracketed by the regular high current (180 $$\\mu$$A) operation of the Compton polarimeter. All measurements were found to be consistent within experimental uncertainties of 1% or less, demonstrating that electron polarization does not depend significantly on the beam current. This result lends confidence to the common practice of applying Moller measurements made at low beam currents to physics experiments performed at higher beam currents. Here, the agreement between two polarimetry techniques based on independent physical processes sets an important benchmark for future precision asymmetry measurements that require sub-1% precision in polarimetry.« less

  13. Improvements of the target lifetime in the RHIC polarimeter

    NASA Astrophysics Data System (ADS)

    Steski, D. B.; Huang, H.; Kewisch, J.; Sukhanova, L.; Zelenski, A.

    2018-05-01

    The Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory (BNL) is the only collider in the world to collide polarized protons. It is critical to the RHIC experimental program that the polarization of the proton beam is measured. This is accomplished with the Coulomb Nuclear Interference (CNI) polarimeter. The targets used in the RHIC CNI polarimeter are 50 nm thick, 25 mm long and <10 µm wide. As the beam intensity in RHIC has increased and the beam size has decreased, the lifetime of these targets has decreased dramatically. During the 2013 polarized proton experimental run, the targets needed to be replaced twice. This resulted in additional work and lost beam time. Before the 2015 experimental run, metal shields were installed around the ends of the targets which greatly improved the target lifetime. The results from the 2015 experimental run and plans for the 2017 experimental run will be discussed.

  14. Design of a dispersion interferometer combined with a polarimeter to increase the electron density measurement reliability on ITER

    NASA Astrophysics Data System (ADS)

    Akiyama, T.; Sirinelli, A.; Watts, C.; Shigin, P.; Vayakis, G.; Walsh, M.

    2016-11-01

    A dispersion interferometer is a reliable density measurement system and is being designed as a complementary density diagnostic on ITER. The dispersion interferometer is inherently insensitive to mechanical vibrations, and a combined polarimeter with the same line of sight can correct fringe jump errors. A proof of the principle of the CO2 laser dispersion interferometer combined with the PEM polarimeter was recently conducted, where the phase shift and the polarization angle were successfully measured simultaneously. Standard deviations of the line-average density and the polarization angle measurements over 1 s are 9 × 1016 m-2 and 0.19°, respectively, with a time constant of 100 μs. Drifts of the zero point, which determine the resolution in steady-state operation, correspond to 0.25% and 1% of the phase shift and the Faraday rotation angle expected on ITER.

  15. Design of a dispersion interferometer combined with a polarimeter to increase the electron density measurement reliability on ITER.

    PubMed

    Akiyama, T; Sirinelli, A; Watts, C; Shigin, P; Vayakis, G; Walsh, M

    2016-11-01

    A dispersion interferometer is a reliable density measurement system and is being designed as a complementary density diagnostic on ITER. The dispersion interferometer is inherently insensitive to mechanical vibrations, and a combined polarimeter with the same line of sight can correct fringe jump errors. A proof of the principle of the CO 2 laser dispersion interferometer combined with the PEM polarimeter was recently conducted, where the phase shift and the polarization angle were successfully measured simultaneously. Standard deviations of the line-average density and the polarization angle measurements over 1 s are 9 × 10 16 m -2 and 0.19°, respectively, with a time constant of 100 μs. Drifts of the zero point, which determine the resolution in steady-state operation, correspond to 0.25% and 1% of the phase shift and the Faraday rotation angle expected on ITER.

  16. A novel comparison of Møller and Compton electron-beam polarimeters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Magee, J. A.; Narayan, A.; Jones, D.

    We have performed a novel comparison between electron-beam polarimeters based on Moller and Compton scattering. A sequence of electron-beam polarization measurements were performed at low beam currents (more » $<$ 5 $$\\mu$$A) during the $$Q_{\\rm weak}$$ experiment in Hall C at Jefferson Lab. These low current measurements were bracketed by the regular high current (180 $$\\mu$$A) operation of the Compton polarimeter. All measurements were found to be consistent within experimental uncertainties of 1% or less, demonstrating that electron polarization does not depend significantly on the beam current. This result lends confidence to the common practice of applying Moller measurements made at low beam currents to physics experiments performed at higher beam currents. Here, the agreement between two polarimetry techniques based on independent physical processes sets an important benchmark for future precision asymmetry measurements that require sub-1% precision in polarimetry.« less

  17. Double-wedged Wollaston-type polarimeter design and integration to RTT150-TFOSC

    NASA Astrophysics Data System (ADS)

    Helhel, Selcuk; Kirbiyik, Halil; Bayar, Cevdet; Khamitov, Irek; Kahya, Gizem; Okuyan, Oguzhan

    2016-07-01

    Photometric and spectroscopic observation capabilities of 1.5-m Russian- Turkish Telescope RTT150 has been broadened with the integration of presented polarimeter. The well-known double-wedged Wollaston-type dual-beam technique was preferred and applied to design and produce it. The designed polarimeter was integrated into the telescope detector TFOSC, and called TFOSC-WP. Its capabil- ities and limitations were attempted to be determined by a number of observation sets. Non-polarized and strongly polarized stars were observed to determine its limi- tations as well as its linearity. An instrumental intrinsic polarization was determined for the 1×5 arcmin field of view in equatorial coordinate system, the systematic error of polarization degree as 0.2% %, and position angle as 1.9°. These limitations and capabilities are denoted as good enough to satisfy telescopes' present and future astrophysical space missions related to GAIA and SRG projects.

  18. Double-wedged Wollaston-type polarimeter design and integration to RTT150-TFOSC; initial tests, calibration, and characteristics

    NASA Astrophysics Data System (ADS)

    Helhel, S.; Khamitov, I.; Kahya, G.; Bayar, C.; Kaynar, S.; Gumerov, R.

    2015-10-01

    Photometric and spectroscopic observation capabilities of 1.5-m Russian-Turkish Telescope RTT150 has been broadened with the integration of presented polarimeter. The well-known double-wedged Wollaston-type dual-beam technique was preferred and applied to design and produce it. The designed polarimeter was integrated into the telescope detector TFOSC, and called TFOSC-WP. Its capabilities and limitations were attempted to be determined by a number of observation sets. Non-polarized and strongly polarized stars were observed to determine its limitations as well as its linearity. An instrumental intrinsic polarization was determined for the 1 × 5 arcmin field of view in equatorial coordinate system, the systematic error of polarization degree as 0.2 %, and position angle as 1.9∘. These limitations and capabilities are denoted as good enough to satisfy telescopes' present and future astrophysical space missions related to GAIA and SRG projects.

  19. The daily 10 kcal expenditure deficit: a before-and-after study on low-cost interventions in the work environment

    PubMed Central

    Dorresteijn, Johannes A N; van der Graaf, Yolanda; Zheng, Kailiang; Spiering, Wilko; Visseren, Frank L J

    2013-01-01

    Objectives To evaluate whether four types of low-cost interventions in the working environment can promote the small everyday lifestyle adaptations that can halt the epidemics of obesity and hypertension when maintained long term. Design A single-blind uninterrupted time-series intervention study consisting of four study periods: run-in (2 weeks), baseline (2 weeks), intervention (2 weeks), and after intervention 2 weeks). Setting University Medical Centre with over 11 000 employees, over 1000 hospital beds and over 2000 customers visiting the hospital restaurant each day. Participants Hospital staff and visitors. Interventions (1) Point-of-decision prompts on hospital elevator doors promoting stair use. (2) Point-of-purchase prompts in the hospital restaurant promoting reduced-salt soup. (3) Point-of-purchase prompts in the hospital restaurant promoting lean croissants. (4) Reversal of the accessibility and availability of diet margarine and butter in the hospital restaurant. Main outcome measures (1) Number of passages through 15 different parts of the hospital staircases. (2) Number and ratio of normal-salt and reduced-salt soup purchased. (3) Number and ratio of butter croissants and lean croissants purchased. (4) Number and ratio of diet margarine and butter purchased. Results Elevator signs increased the mean 24-h number of stair passages per measurement site (baseline: 992 ± 479 on week days and 208 ± 116 on weekend days) by 11.2% (95% CI 8.7% to 13.7%). This effect was maintained at least 2 weeks after the point-of-decision prompts were removed. Point-of-purchase prompts promoting low-salt soup and lean croissants did not result in altered purchase behaviour. The ratio between the purchase of margarine and butter was changed sevenfold (p<0.01) by reversing the positions of these products in the hospital restaurant. Conclusions Healthy lifestyle adaptations in the working environment can be effectively promoted by making healthy choices easier than unhealthy ones. Educational prompts at points-of-decision moderately increase stair climbing, but do not affect healthy food choices. Protocol registration Clinicaltrials.gov identifier number: NCT01574040. PMID:23355669

  20. The daily 10 kcal expenditure deficit: a before-and-after study on low-cost interventions in the work environment.

    PubMed

    Dorresteijn, Johannes A N; van der Graaf, Yolanda; Zheng, Kailiang; Spiering, Wilko; Visseren, Frank L J

    2013-01-24

    To evaluate whether four types of low-cost interventions in the working environment can promote the small everyday lifestyle adaptations that can halt the epidemics of obesity and hypertension when maintained long term. A single-blind uninterrupted time-series intervention study consisting of four study periods: run-in (2 weeks), baseline (2 weeks), intervention (2 weeks), and after intervention 2 weeks). University Medical Centre with over 11 000 employees, over 1000 hospital beds and over 2000 customers visiting the hospital restaurant each day. Hospital staff and visitors. (1) Point-of-decision prompts on hospital elevator doors promoting stair use. (2) Point-of-purchase prompts in the hospital restaurant promoting reduced-salt soup. (3) Point-of-purchase prompts in the hospital restaurant promoting lean croissants. (4) Reversal of the accessibility and availability of diet margarine and butter in the hospital restaurant. (1) Number of passages through 15 different parts of the hospital staircases. (2) Number and ratio of normal-salt and reduced-salt soup purchased. (3) Number and ratio of butter croissants and lean croissants purchased. (4) Number and ratio of diet margarine and butter purchased. Elevator signs increased the mean 24-h number of stair passages per measurement site (baseline: 992 ± 479 on week days and 208 ± 116 on weekend days) by 11.2% (95% CI 8.7% to 13.7%). This effect was maintained at least 2 weeks after the point-of-decision prompts were removed. Point-of-purchase prompts promoting low-salt soup and lean croissants did not result in altered purchase behaviour. The ratio between the purchase of margarine and butter was changed sevenfold (p<0.01) by reversing the positions of these products in the hospital restaurant. Healthy lifestyle adaptations in the working environment can be effectively promoted by making healthy choices easier than unhealthy ones. Educational prompts at points-of-decision moderately increase stair climbing, but do not affect healthy food choices. Clinicaltrials.gov identifier number: NCT01574040.

  1. “Toxic” beef bone soup

    PubMed Central

    Pandita, Kamal Kishore; Pandita, Sarla; Hassan, Tanveer

    2011-01-01

    Summary Hypercalcaemia is most commonly caused by primary hyperparathyroidism or malignancy. Vitamin D intoxication, also a cause of hypercalcaemia, is mostly caused by excessive administration of vitamin D-containing medications and excessive intake of foods fortified with vitamin D. We present a young cricketer, with recurrent vomiting due to hypercalcaemia and hypervitaminosis D, who used to drink large volumes of soup prepared by boiling long beef bones, for many months. This case presentation highlights the importance of in-depth dietary history for arriving at proper diagnosis. PMID:22461816

  2. Parenteral nutrition combined with rice soup can be a safe and effective intervention for congenital chylous ascites.

    PubMed

    Cao, Yi; Yan, Weihui; Lu, Lina; Tao, Yijing; Lu, Wei; Chen, Yingwei; Tang, Qingya; Cai, Wei

    2016-01-01

    Congenital chylous ascites in the neonatal period is a rare entity. Total parenteral nutrition (TPN), medium chain triglyceride (MCT)-based diet, octreotide and repeated paracentesis are regarded as appropriate medical treatment for congenital chylous ascites, and surgery is recommended when conservative therapy has failed. We present two cases in which ascites were confirmed via an abdominal sonogram and diagnostic paracentesis. In our clinical experience, rice soup combined with PN can be a safe and effective intervention.

  3. The Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP)

    NASA Technical Reports Server (NTRS)

    Ishikawa, Shin-nosuke; Kano, R.; Kobayashi, K.; Bando, T.; Narukage, N..; Ishikawa, R.; Kubo, M.; Katsukawa, Y.; Suematsu, Y.; Hara, H.; hide

    2014-01-01

    To Understand energy release process in the Sun including solar flares, it is essentially important to measure the magnetic field of the atmosphere of the Sun. Magnetic field measurement of the upper layers (upper chromosphere and above) was technically difficult and not well investigated yet. Upper chromosphere and transition region magnetic field measurement by Chromospheric Lyman-Alpha SpectroPolarimeter (CLASP) sounding rocket to be launched in 2015. The proposal is already selected and developments of the flight components are going.

  4. Development of absorber coupled TES polarimeter at millimeter wavelengths.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, G.; Yefremenko, V.; Novosad, V.

    2009-06-01

    We report an absorber coupled TES bolometric polarimeter, consisting of an absorptive metal grid and a Mo/Au bi-layer TES on a suspended silicon nitride membrane disk. The electromagnetic design of the polarization sensitive absorbers, the heat transport modeling of the detector, the thermal response of the TES, and the micro-fabrication processes are presented. We also report the results of laboratory tests of a single pixel prototype detector, and compare with theoretical expectations.

  5. Terrace retro-reflector array for poloidal polarimeter on ITER.

    PubMed

    Imazawa, R; Kawano, Y; Ono, T; Kusama, Y

    2011-02-01

    A new concept of a terrace retro-reflector array (TERRA) as part of the poloidal polarimeter for ITER is proposed in this paper. TERRA reflects a laser light even from a high incident angle in the direction of the incident-light path, while a conventional retro-reflector array cannot. Besides, TERRA can be installed in a smaller space than a corner-cube retro-reflector. In an optical sense, TERRA is equivalent to a Littrow grating, the blaze angle of which varies, depending on the incident angle. The reflected light generates a bright and dark fringe, and the bright fringe is required to travel along the incident-light path to achieve the objects of laser-aided diagnostics. In order to investigate the propagation properties of laser light reflected by TERRA, we have developed a new diffraction formula. Conditions for the propagation of the bright fringe in the direction of the incident light have been obtained using the Littrow grating model and have been confirmed in a simulation applying the new diffraction formula. Finally, we have designed laser transmission optics using TERRA for the ITER poloidal polarimeter and have calculated the light propagation of the system. The optical design obtains a high transmission efficiency, with 88.6% of the incident power returned. These results demonstrate the feasibility of applying TERRA to the ITER poloidal polarimeter.

  6. X-Ray Spectro-Polarimetry with Photoelectric Polarimeters

    NASA Technical Reports Server (NTRS)

    Strohmayer, T. E.

    2017-01-01

    We derive a generalization of forward fitting for X-ray spectroscopy to include linear polarization of X-ray sources, appropriate for the anticipated next generation of space-based photoelectric polarimeters. We show that the inclusion of polarization sensitivity requires joint fitting to three observed spectra, one for each of the Stokes parameters, I(E), U(E), and Q(E). The equations for StokesI (E) (the total intensity spectrum) are identical to the familiar case with no polarization sensitivity, and for which the model-predicted spectrum is obtained by a convolution of the source spectrum, F (E), with the familiar energy response function,(E) R(E,E), where (E) and R(E,E) are the effective area and energy redistribution matrix, respectively. In addition to the energy spectrum, the two new relations for U(E) and Q(E) include the source polarization fraction and position angle versus energy, a(E), and 0(E), respectively, and the model-predicted spectra for these relations are obtained by a convolution with the modulated energy response function, (E)(E) R(E,E), where(E) is the energy-dependent modulation fraction that quantifies a polarimeters angular response to 100 polarized radiation. We present results of simulations with response parameters appropriate for the proposed PRAXyS Small Explorer observatory to illustrate the procedures and methods, and we discuss some aspects of photoelectric polarimeters with relevance to understanding their calibration and operation.

  7. A cryogenic waveplate rotator for polarimetry at mm and submm wavelengths

    NASA Astrophysics Data System (ADS)

    Salatino, M.; de Bernardis, P.; Masi, S.

    2011-04-01

    Context. Polarimetry at mm and submm wavelengths is the new frontier of research in cosmic microwave background and interstellar dust studies. Polarimeters working in the IR to MM range need to be operated at cryogenic temperatures to limit the systematic effects related to the emission of the polarization analyzer. Aims: We study the effect of the temperature of the different components of a waveplate polarimeter and describe a system able to rotate a birefringent crystal at 4 K in a completely automated way. Methods: We simulate the main systematic effects related to the temperature and non-ideality of the optical components in a Stokes polarimeter. To limit these effects, a cryogenic implementation of the polarimeter is mandatory. In our system, the rotation produced by a step motor running at room temperature is transmitted down to cryogenic temperatures by means of a long shaft and gears running on custom cryogenic bearings. Results: Our system is able to rotate a birefringent crystal at 4 K in a completely automated way and dissipates only a few mW in the cold environment. A readout system based on optical fibers allows us to control the rotation of the crystal to better than 0.1°. Conclusions: This device fulfills the stringent requirements for operations in cryogenic space experiments, such as the forthcoming PILOT, BOOMERanG and LSPE.

  8. On the Relation Between Facular Bright Points and the Magnetic Field

    NASA Astrophysics Data System (ADS)

    Berger, Thomas; Shine, Richard; Tarbell, Theodore; Title, Alan; Scharmer, Goran

    1994-12-01

    Multi-spectral images of magnetic structures in the solar photosphere are presented. The images were obtained in the summers of 1993 and 1994 at the Swedish Solar Telescope on La Palma using the tunable birefringent Solar Optical Universal Polarimeter (SOUP filter), a 10 Angstroms wide interference filter tuned to 4304 Angstroms in the band head of the CH radical (the Fraunhofer G-band), and a 3 Angstroms wide interference filter centered on the Ca II--K absorption line. Three large format CCD cameras with shuttered exposures on the order of 10 msec and frame rates of up to 7 frames per second were used to create time series of both quiet and active region evolution. The full field--of--view is 60times 80 arcseconds (44times 58 Mm). With the best seeing, structures as small as 0.22 arcseconds (160 km) in diameter are clearly resolved. Post--processing of the images results in rigid coalignment of the image sets to an accuracy comparable to the spatial resolution. Facular bright points with mean diameters of 0.35 arcseconds (250 km) and elongated filaments with lengths on the order of arcseconds (10(3) km) are imaged with contrast values of up to 60 % by the G--band filter. Overlay of these images on contemporal Fe I 6302 Angstroms magnetograms and Ca II K images reveals that the bright points occur, without exception, on sites of magnetic flux through the photosphere. However, instances of concentrated and diffuse magnetic flux and Ca II K emission without associated bright points are common, leading to the conclusion that the presence of magnetic flux is a necessary but not sufficient condition for the occurence of resolvable facular bright points. Comparison of the G--band and continuum images shows a complex relation between structures in the two bandwidths: bright points exceeding 350 km in extent correspond to distinct bright structures in the continuum; smaller bright points show no clear relation to continuum structures. Size and contrast statistical cross--comparisons compiled from measurements of over two-thousand bright point structures are presented. Preliminary analysis of the time evolution of bright points in the G--band reveals that the dominant mode of bright point evolution is fission of larger structures into smaller ones and fusion of small structures into conglomerate structures. The characteristic time scale for the fission/fusion process is on the order of minutes.

  9. Nutritional and functional characterization of barley flaxseed based functional dry soup mix.

    PubMed

    Kaur, Sumeet; Das, Madhusweta

    2015-09-01

    Barley flaxseed based functional dry soup mix (BFSM) was developed from whole barely flour (46.296%), roasted flaxseed powder (23.148%) and the seasoning (30.555%) comprising several flavoring compounds and anticaking agent, using simple processing technique. Developed BFSM was nutritious. On dry matter basis it contained: protein (14.31%), carbohydrate excluding crude fiber (54.70%), fat (8.70%), ash (17.45%) and crude fiber (4.84%). It was low glycemic soup, free of antinutritional risk and had calorific value of 319.77 kcal/100 g (wet or sample basis, sb) estimated from its composition. 100 g (sb) of BFSM contained 4.36 g β-glucans and 8.08 g total lipid of which 25.6% was ω-3 fatty acids. Different extracts of BFSM revealed the presence of total phenols (0.57-1.86 mg gallic acid equivalent/g, sb) with antioxidants equivalence of DPPH (20.69-39.07%) and FRAP (120-331 μm Fe (II)/g, sb).

  10. Food effect: The combined effect of media pH and viscosity on the gastrointestinal absorption of ciprofloxacin tablet.

    PubMed

    Radwan, Asma; Zaid, Abdel Naser; Jaradat, Nidal; Odeh, Yousef

    2017-04-01

    The clinical implications of food-drug interactions may have to be taken seriously into account with oral drugs administration in order to minimize variations in drug bioavailability. Food intake may alter physiological changes in the pH and viscosity of the gastrointestinal lumen, which could affect the oral absorption of drugs. The aim of the present study was to have an insight on the effect of media parameters: viscosity and pHon the oral absorption of ciprofloxacin HCl from solid formulations using a model food: Corchorus olitorius (Jute) Soup. In vitro disintegration and dissolution rates of ciprofloxacin tablet were evaluated using compendia buffer media in the presence/absence of C. olitorius leaves. These in vitro data were then input to GastroPlus™ to predict ciprofloxacin absorption profiles under fasted and fed states. The present study demonstrated the significance of luminal pH and viscosity on the dissolution and disintegration of solid formulations following postprandial ingestion of the viscous soup. The tablets showed prolonged disintegration times and reduced dissolution rates in this soup, which could be attributed to the postprandial elevation in media viscosity and reduced solubility at elevated gastricpH. The predicted model under fed state showed no impact on AUC but prolonged T max and a decrease in C max . Concomitant intake of C. olitorius soup with ciprofloxacin might have negative effect on the rate of drug release from conventional immediate release tablets. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. 5 MeV Mott polarimeter for rapid precise electron beam polarization measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Price, J.S.; Poelker, B.M.; Sinclair, C.K.

    1997-11-01

    Low energy (E{sub k} = 100 keV) Mott scattering polarimeters are ill-suited to support operations foreseen for the polarized electron injector at Jefferson Lab. One solution is to measure the polarization at 5 MeV where multiple and plural scattering are unimportant and precision beam monitoring is straightforward. The higher injector beam current offsets the lower cross-sections; measured rates scale to 1 kHz/{mu}A with a 1 {mu}m thick gold target foil.

  12. The Cosmology Large Angular Scale Surveyor (CLASS): 38 GHz Detector Array of Bolometric Polarimeters

    NASA Technical Reports Server (NTRS)

    Appel, John W.; Ali, Aamir; Amiri, Mandana; Araujo, Derek; Bennett, Charles L.; Boone, Fletcher; Chan, Manwei; Cho, Hsiao-Mei; Chuss, David T.; Colazo, Felipe; hide

    2014-01-01

    The Cosmology Large Angular Scale Surveyor (CLASS) experiment aims to map the polarization of the Cosmic Microwave Background (CMB) at angular scales larger than a few degrees. Operating from Cerro Toco in the Atacama Desert of Chile, it will observe over 65% of the sky at 38, 93, 148, and 217 GHz. In this paper we discuss the design, construction, and characterization of the CLASS 38 GHz detector focal plane, the first ever Q-band bolometric polarimeter array.

  13. The cosmology large angular scale surveyor (CLASS): 38-GHz detector array of bolometric polarimeters

    NASA Astrophysics Data System (ADS)

    Appel, John W.; Ali, Aamir; Amiri, Mandana; Araujo, Derek; Bennet, Charles L.; Boone, Fletcher; Chan, Manwei; Cho, Hsiao-Mei; Chuss, David T.; Colazo, Felipe; Crowe, Erik; Denis, Kevin; Dünner, Rolando; Eimer, Joseph; Essinger-Hileman, Thomas; Gothe, Dominik; Halpern, Mark; Harrington, Kathleen; Hilton, Gene; Hinshaw, Gary F.; Huang, Caroline; Irwin, Kent; Jones, Glenn; Karakula, John; Kogut, Alan J.; Larson, David; Limon, Michele; Lowry, Lindsay; Marriage, Tobias; Mehrle, Nicholas; Miller, Amber D.; Miller, Nathan; Moseley, Samuel H.; Novak, Giles; Reintsema, Carl; Rostem, Karwan; Stevenson, Thomas; Towner, Deborah; U-Yen, Kongpop; Wagner, Emily; Watts, Duncan; Wollack, Edward; Xu, Zhilei; Zeng, Lingzhen

    2014-07-01

    The Cosmology Large Angular Scale Surveyor (CLASS) experiment aims to map the polarization of the Cosmic Microwave Background (CMB) at angular scales larger than a few degrees. Operating from Cerro Toco in the Atacama Desert of Chile, it will observe over 65% of the sky at 38, 93, 148, and 217 GHz. In this paper we discuss the design, construction, and characterization of the CLASS 38 GHz detector focal plane, the first ever Q-band bolometric polarimeter array.

  14. Observational Aspects of Hard X-ray Polarimetry

    NASA Astrophysics Data System (ADS)

    Chattopadhyay, Tanmoy

    2016-04-01

    Sensitive polarization measurements in X-ray may address a wealth of astrophysical phenomena, which so far remain beyond our understanding through available X-ray spectroscopic, imaging, and timing studies. Though scientific potential of X-ray polarimetry was realized long ago, there has not been any significant advancement in this field for the last four decades since the birth of X-ray astronomy. The only successful polarization measurement in X-rays dates back to 1976, when a Bragg polarimeter onboard OSO-8 measured polarization of Crab nebula. Primary reason behind the lack in progress is its extreme photon hungry nature, which results in poor sensitivity of the polarimeters. Recently, in the last decade or so, with the advancement in detection technology, X-ray polarimetry may see a significant progress in near future, especially in soft X-rays with the invention of photoelectron tracking polarimeters. Though photoelectric polarimeters are expected to provide sensitive polarization measurements of celestial X-ray sources, they are sensitive only in soft X-rays, where the radiation from the sources is dominated by thermal radiation and therefore expected to be less polarized. On the other hand, in hard X-rays, sources are ex-pected to be highly polarized due to the dominance of nonthermal emission over its thermal counterpart. Moreover, polarization measurements in hard X-rays promises to address few interesting scientific issues regarding geometry of corona for black hole sources, emission mechanism responsible for the higher energy peak in the blazars, accretion geometry close to the magnetic poles in accreting neutron star systems and acceleration mechanism in solar flares. Compton polarimeters provide better sensitivity than photoelectric polarimeters in hard X-rays with a broad energy band of operation. Recently, with the development of hard X-ray focusing optics e.g. NuSTAR, Astro-H, it is now possible to conceive Compton polarimeters at the focal plane of such hard X-ray telescopes, which may provide sensitive polarization measurements due to flux concentration in hard X-rays with a very low background. On the other hand, such a configuration ensures implementation of an optimized geometry close to an ideal one for the Compton polarimeters. In this context, we initiated the development of a focal plane Compton polarimeter, consisting of a plastic scatterer surrounded by a cylindrical array of CsI(Tl) scintillators. Geant-4 simulations of the planned configuration estimates 1% MDP for a 100 mCrab source in 1 million seconds of exposure. Sensitivity of the instrument is found to be critically dependent on the lower energy detection limit of the plastic scatterer; lower the threshold, better is the sensitivity. In the actual experiment, the plastic is readout by a photomultiplier tube procured from Saint-Gobain. We carried out extensive experiments to characterize the plastic especially for lower energy depositions. The CsI(Tl) scintillators are readout by Si photomultipliers (SiPM). SiPMs are small in size and robust and therefore provide the compactness necessary for the designing of focal plane detectors. Each of the CsI(Tl)-SiPM systems was characterized precisely to estimate their energy threshold and detection probability along the length of the scintillators away from SiPM. Finally, we integrated the Compton polarimeter and tested its response to polarized and unpolarized radiation and compared the experimental results with Geant-4 simulation. Despite the growing realization of the scientific values of X-ray polarimetry and the efforts in developing sensitive X-ray polarimeters, there has not been a single dedicated X-ray polarimetry mission planned in near future. In this scenario, it is equally important to attempt polarization measurements from the existing or planned instruments which are not meant for X-ray polarization measurements but could be sensitive to it. There have been several attempts in past in retrieving polarization information from few of such spectroscopic instruments like RHESSI, INTEGRAL-IBIS, INTEGRAL-SPI. Cadmium Zinc Telluride Imager (CZTI) onboard Astrosat, India's first astronomical mission, is one of such instruments which is expected to provide sensitive polarization measurements for bright X-ray sources. CZTI consists of 64 CZT detector modules, each of which is 5 mm thick and 4 cm × 4 cm in size. Each CZT module is subdivided into 256 pixels with pixel pitch of 2.5 mm. Due to its pixelation nature and significant Compton scattering efficiency at energies beyond 100 keV, CZTI can work as a sensitive Compton polarimeter in hard X-rays. Detailed Geant-4 simulations and polarization experiments with the flight configuration of CZTI show that CZTI will have significant polarization measurement capability for bright sources in hard X-rays. CZTI is primarily a spectroscopic instrument with coded mask imaging. To properly utilize the spectroscopic capabilities of CZT detectors, it is important to generate accurate response matrix for CZTI, which in turn requires precise modelling of the CZT lines shapes for monoenergetic X-ray interaction. CZT detectors show an extended lower energy tail of an otherwise Gaussian line shape due to low mobility and lifetime of the charge carriers. On the other hand, interpixel charge sharing may also contribute to the lower energy tail making the line shape more complicated. We have developed a model to predict the line shapes from CZTI modules taking into account the mobility and lifetime of the charge carriers and charge sharing fractions. The model predicts the line shape quite well and can be used to generate pixel-wise response matrix for CZTI.

  15. Simultaneous aerosol/ocean products retrieved during the 2014 SABOR campaign using the NASA Research Scanning Polarimeter (RSP)

    NASA Astrophysics Data System (ADS)

    Stamnes, S.; Hostetler, C. A.; Ferrare, R. A.; Hair, J. W.; Burton, S. P.; Liu, X.; Hu, Y.; Stamnes, K. H.; Chowdhary, J.; Brian, C.

    2017-12-01

    The SABOR (Ship-Aircraft Bio-Optical Research) campaign was conducted during the summer of 2014, in the Atlantic Ocean, over the Chesapeake Bay and the eastern coastal region of the United States. The NASA GISS Research Scanning Polarimeter, a multi-angle, multi-spectral polarimeter measured the upwelling polarized radiances from a B200 aircraft. We present results from the new "MAPP" algorithm for RSP that is based on optimal estimation and that can retrieve simultaneous aerosol microphysical properties (including effective radius, single-scattering albedo, and real refractive index) and ocean color products using accurate radiative transfer and Mie calculations. The algorithm was applied to data collected during SABOR to retrieve aerosol microphysics and ocean products for all Aerosols-Above-Ocean (AAO) scenes. The RSP MAPP products are compared against collocated aerosol extinction and backscatter profiles collected by the NASA LaRC airborne High Spectral Resolution Lidar (HSRL-1), including lidar depth profiles of the ocean diffuse attenuation coefficient and the hemispherical backscatter coefficient.

  16. Astronomical Polarimetry with the RIT Polarization Imaging Camera

    NASA Astrophysics Data System (ADS)

    Vorobiev, Dmitry V.; Ninkov, Zoran; Brock, Neal

    2018-06-01

    In the last decade, imaging polarimeters based on micropolarizer arrays have been developed for use in terrestrial remote sensing and metrology applications. Micropolarizer-based sensors are dramatically smaller and more mechanically robust than other polarimeters with similar spectral response and snapshot capability. To determine the suitability of these new polarimeters for astronomical applications, we developed the RIT Polarization Imaging Camera to investigate the performance of these devices, with a special attention to the low signal-to-noise regime. We characterized the device performance in the lab, by determining the relative throughput, efficiency, and orientation of every pixel, as a function of wavelength. Using the resulting pixel response model, we developed demodulation procedures for aperture photometry and imaging polarimetry observing modes. We found that, using the current calibration, RITPIC is capable of detecting polarization signals as small as ∼0.3%. The relative ease of data collection, calibration, and analysis provided by these sensors suggest than they may become an important tool for a number of astronomical targets.

  17. Liquid Water Cloud Properties During the Polarimeter Definition Experiment (PODEX)

    NASA Technical Reports Server (NTRS)

    Alexandrov, Mikhail D.; Cairns, Brian; Wasilewski, Andrzei P.; Ackerman, Andrew S.; McGill, Matthew J.; Yorks, John E.; Hlavka, Dennis L.; Platnick, Steven; Arnold, George; Van Diedenhoven, Bastiaan; hide

    2015-01-01

    We present retrievals of water cloud properties from the measurements made by the Research Scanning Polarimeter (RSP) during the Polarimeter Definition Experiment (PODEX) held between January 14 and February 6, 2013. The RSP was onboard the high-altitude NASA ER-2 aircraft based at NASA Dryden Aircraft Operation Facility in Palmdale, California. The retrieved cloud characteristics include cloud optical thickness, effective radius and variance of cloud droplet size distribution derived using a parameter-fitting technique, as well as the complete droplet size distribution function obtained by means of Rainbow Fourier Transform. Multi-modal size distributions are decomposed into several modes and the respective effective radii and variances are computed. The methodology used to produce the retrieval dataset is illustrated on the examples of a marine stratocumulus deck off California coast and stratus/fog over California's Central Valley. In the latter case the observed bimodal droplet size distributions were attributed to two-layer cloud structure. All retrieval data are available online from NASA GISS website.

  18. A soft X-ray beam-splitting multilayer optic for the NASA GEMS Bragg Reflection Polarimeter

    DOE PAGES

    Allured, Ryan; Kaaret, Philip; Fernandez-Perea, Monica; ...

    2013-04-12

    A soft X-ray, beam-splitting, multilayer optic has been developed for the Bragg Reflection Polarimeter (BRP) on the NASA Gravity and Extreme Magnetism Small Explorer Mission (GEMS). The optic is designed to reflect 0.5 keV X-rays through a 90° angle to the BRP detector, and transmit 2–10 keV X-rays to the primary polarimeter. The transmission requirement prevents the use of a thick substrate, so a 2 μm thick polyimide membrane was used. Atomic force microscopy has shown the membrane to possess high spatial frequency roughness less than 0.2 nm rms, permitting adequate X-ray reflectance. A multilayer thin film was especially developedmore » and deposited via magnetron sputtering with reflectance and transmission properties that satisfy the BRP requirements and with near-zero stress. Furthermore, reflectance and transmission measurements of BRP prototype elements closely match theoretical predictions, both before and after rigorous environmental testing.« less

  19. A soft X-ray beam-splitting multilayer optic for the NASA GEMS Bragg Reflection Polarimeter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Allured, Ryan; Kaaret, Philip; Fernandez-Perea, Monica

    A soft X-ray, beam-splitting, multilayer optic has been developed for the Bragg Reflection Polarimeter (BRP) on the NASA Gravity and Extreme Magnetism Small Explorer Mission (GEMS). The optic is designed to reflect 0.5 keV X-rays through a 90° angle to the BRP detector, and transmit 2–10 keV X-rays to the primary polarimeter. The transmission requirement prevents the use of a thick substrate, so a 2 μm thick polyimide membrane was used. Atomic force microscopy has shown the membrane to possess high spatial frequency roughness less than 0.2 nm rms, permitting adequate X-ray reflectance. A multilayer thin film was especially developedmore » and deposited via magnetron sputtering with reflectance and transmission properties that satisfy the BRP requirements and with near-zero stress. Furthermore, reflectance and transmission measurements of BRP prototype elements closely match theoretical predictions, both before and after rigorous environmental testing.« less

  20. An examination of the sensitivity and systematic error of the NASA GEMS Bragg Reflection Polarimeter using Monte-Carlo simulations

    NASA Astrophysics Data System (ADS)

    Allured, Ryan; Okajima, Takashi; Soufli, Regina; Fernández-Perea, Mónica; Daly, Ryan O.; Marlowe, Hannah; Griffiths, Scott T.; Pivovaroff, Michael J.; Kaaret, Philip

    2012-10-01

    The Bragg Reflection Polarimeter (BRP) on the NASA Gravity and Extreme Magnetism Small Explorer Mission is designed to measure the linear polarization of astrophysical sources in a narrow band centered at about 500 eV. X-rays are focused by Wolter I mirrors through a 4.5 m focal length to a time projection chamber (TPC) polarimeter, sensitive between 2{10 keV. In this optical path lies the BRP multilayer reflector at a nominal 45 degree incidence angle. The reflector reflects soft X-rays to the BRP detector and transmits hard X-rays to the TPC. As the spacecraft rotates about the optical axis, the reflected count rate will vary depending on the polarization of the incident beam. However, false polarization signals may be produced due to misalignments and spacecraft pointing wobble. Monte-Carlo simulations have been carried out, showing that the false modulation is below the statistical uncertainties for the expected focal plane offsets of < 2 mm.

  1. Spectrum orbit utilization program technical manual SOUP5 Version 3.8

    NASA Technical Reports Server (NTRS)

    Davidson, J.; Ottey, H. R.; Sawitz, P.; Zusman, F. S.

    1984-01-01

    The underlying engineering and mathematical models as well as the computational methods used by the SOUP5 analysis programs, which are part of the R2BCSAT-83 Broadcast Satellite Computational System, are described. Included are the algorithms used to calculate the technical parameters and references to the relevant technical literature. The system provides the following capabilities: requirements file maintenance, data base maintenance, elliptical satellite beam fitting to service areas, plan synthesis from specified requirements, plan analysis, and report generation/query. Each of these functions are briefly described.

  2. Story of Stone Soup: A Recipe to Improve Health Disparities

    PubMed Central

    Chung, Bowen; Jones, Loretta; Terry, Chrystene; Jones, Andrea; Forge, Nell; Norris, Keith C.

    2013-01-01

    Just as scientific articles are used as a way of sharing knowledge in scientific communities, stories are used as a way of transferring knowledge within African American communities. This article uses the story and metaphor of Stone Soup to illustrate the Healthy African American Families' (HAAF) Community Partnered Participatory Research (CPPR) method of engaging diverse partners to address health issues, such as preterm birth, depression, diabetes, and kidney disease, and to create community-wide change through education, capacity building, resource sharing, and intervention development. PMID:20629241

  3. Small Sample Studies of Food Habits: I. The Relationship between Food Preference and Food Choice in Naval Enlisted Personnel at the Naval Construction Battalion Center, Davisville, Rhode Island

    DTIC Science & Technology

    1974-10-01

    6-44 102. French onion soup 6-48 103. Strawberry milk shake 6-52 104. Sprite 6-56 105. Broccoli w/mock hollandaise sauce 6-60 106. Parmesan...Sandwich with Brown Gravy Grilled Cheeseburger on Toasted Roll Grilled Hamburger on Toasted Roll. • • < Broccoli with Mock Hollandaise Sauce ...MEAL APPENDIX B NAME/NUMBER ♦Beef Barley Soup _ Croutons > _ ♦Baked Virginia Ham with Pineapple Raisin Sauce _ Grilled Frankfurter on Toasted

  4. Deriving Cloud Droplet Number Concentration from Combined Airborne Lidar and Polarimeter Measurements from the NAAMES Mission

    NASA Astrophysics Data System (ADS)

    Hair, J. W.; Hostetler, C. A.; Brian, C.; Ziemba, L. D.; Alexandrov, M. D.; Hu, Y.; Crosbie, E.; Scarino, A. J.; Butler, C. F.; Moore, R.; Berkoff, T.; Harper, D. B.; Cook, A. L.; Hare, R. J.; Lee, J.; Anderson, B. E.

    2017-12-01

    The NASA Langley High Spectral Resolution lidar (HSRL) and the NASA GISS Research Scanning Polarimeter (RSP) were deployed onboard the NASA C-130 during two field campaigns as part of the NASA's Earth Venture-Suborbital (EVS) North Atlantic Aerosol and Marine Ecosystems Study (NAAMES) during November 2015 and May 2016. The main objectives of NAAMES are to study the phases of the North Atlantic annual plankton cycle and to investigate remote marine aerosols and their impact on boundary layer clouds. Lidar retrievals of the cloud-top extinction and lidar ratio (extinction/backscatter ratio) of boundary layer clouds are presented. These retrievals are unique and are enabled by two characteristics of the lidar: employment of the high-spectral-resolution lidar technique and the high-vertical-resolution (1.25 m) the Langley HSRL instrument. The HSRL lidar ratio retrievals are compared to estimates derived from Research Scanning Polarimeter data to assess consistency between the two remote sensors. The measurements of effective size and variance from RSP are combined with the HSRL cloud top extinction to retrieve the cloud droplet number concentrations (CDNC). The lidar+polarimeter CDNC estimates are compared to those from the Cloud Droplet Probe (CDP) that is part of the NASA Langley Aerosol Research Group Experiment (LARGE) instrument suite. Histograms of the CNDC measurements from remote sensors are shown to highlight the observed differences in CDNC between the November and May deployments.

  5. Mitigation of image artifacts in LWIR microgrid polarimeter images

    NASA Astrophysics Data System (ADS)

    Ratliff, Bradley M.; Tyo, J. Scott; Boger, James K.; Black, Wiley T.; Bowers, David M.; Kumar, Rakesh

    2007-09-01

    Microgrid polarimeters, also known as division of focal plane (DoFP) polarimeters, are composed of an integrated array of micropolarizing elements that immediately precedes the FPA. The result of the DoFP device is that neighboring pixels sense different polarization states. The measurements made at each pixel can be combined to estimate the Stokes vector at every reconstruction point in a scene. DoFP devices have the advantage that they are mechanically rugged and inherently optically aligned. However, they suffer from the severe disadvantage that the neighboring pixels that make up the Stokes vector estimates have different instantaneous fields of view (IFOV). This IFOV error leads to spatial differencing that causes false polarization signatures, especially in regions of the image where the scene changes rapidly in space. Furthermore, when the polarimeter is operating in the LWIR, the FPA has inherent response problems such as nonuniformity and dead pixels that make the false polarization problem that much worse. In this paper, we present methods that use spatial information from the scene to mitigate two of the biggest problems that confront DoFP devices. The first is a polarimetric dead pixel replacement (DPR) scheme, and the second is a reconstruction method that chooses the most appropriate polarimetric interpolation scheme for each particular pixel in the image based on the scene properties. We have found that these two methods can greatly improve both the visual appearance of polarization products as well as the accuracy of the polarization estimates, and can be implemented with minimal computational cost.

  6. Millimeter-Wave Polarimeters Using Kinetic Inductance Detectors for TolTEC and Beyond

    NASA Astrophysics Data System (ADS)

    Austermann, J. E.; Beall, J. A.; Bryan, S. A.; Dober, B.; Gao, J.; Hilton, G.; Hubmayr, J.; Mauskopf, P.; McKenney, C. M.; Simon, S. M.; Ullom, J. N.; Vissers, M. R.; Wilson, G. W.

    2018-05-01

    Microwave kinetic inductance detectors (MKIDs) provide a compelling path forward to the large-format polarimeter, imaging, and spectrometer arrays needed for next-generation experiments in millimeter-wave cosmology and astronomy. We describe the development of feedhorn-coupled MKID detectors for the TolTEC millimeter-wave imaging polarimeter being constructed for the 50-m Large Millimeter Telescope (LMT). Observations with TolTEC are planned to begin in early 2019. TolTEC will comprise ˜ 7000 polarization-sensitive MKIDs and will represent the first MKID arrays fabricated and deployed on monolithic 150 mm diameter silicon wafers—a critical step toward future large-scale experiments with over 10^5 detectors. TolTEC will operate in observational bands at 1.1, 1.4, and 2.0 mm and will use dichroic filters to define a physically independent focal plane for each passband, thus allowing the polarimeters to use simple, direct-absorption inductive structures that are impedance matched to incident radiation. This work is part of a larger program at NIST-Boulder to develop MKID-based detector technologies for use over a wide range of photon energies spanning millimeter-waves to X-rays. We present the detailed pixel layout and describe the methods, tools, and flexible design parameters that allow this solution to be optimized for use anywhere in the millimeter and sub-millimeter bands. We also present measurements of prototype devices operating in the 1.1 mm band and compare the observed optical performance to that predicted from models and simulations.

  7. Self-calibration of Cosmic Microwave Background Polarization Experiments

    NASA Astrophysics Data System (ADS)

    Keating, Brian G.; Shimon, Meir; Yadav, Amit P. S.

    2013-01-01

    Precision measurements of the polarization of the cosmic microwave background (CMB) radiation, especially experiments seeking to detect the odd-parity "B-modes," have far-reaching implications for cosmology. To detect the B-modes generated during inflation, the flux response and polarization angle of these experiments must be calibrated to exquisite precision. While suitable flux calibration sources abound, polarization angle calibrators are deficient in many respects. Man-made polarized sources are often not located in the antenna's far-field, have spectral properties that are radically different from the CMB's, are cumbersome to implement, and may be inherently unstable over the (long) duration these searches require to detect the faint signature of the inflationary epoch. Astrophysical sources suffer from time, frequency, and spatial variability, are not visible from all CMB observatories, and none are understood with sufficient accuracy to calibrate future CMB polarimeters seeking to probe inflationary energy scales of 1015 GeV. Both man-made and astrophysical sources require dedicated observations which detract from the amount of integration time usable for detection of the inflationary B-modes. CMB TB and EB modes, expected to identically vanish in the standard cosmological model, can be used to calibrate CMB polarimeters. By enforcing the observed EB and TB power spectra to be consistent with zero, CMB polarimeters can be calibrated to levels not possible with man-made or astrophysical sources. All of this can be accomplished for any polarimeter without any loss of observing time using a calibration source which is spectrally identical to the CMB B-modes.

  8. Feasibility of a far infrared laser based polarimeter diagnostic system for the JT-60SA fusion experiment

    NASA Astrophysics Data System (ADS)

    Boboc, A.; Gil, C.; Terranova, D.; Orsitto, F. P.; Soare, S.; Lotte, P.; Sozzi, C.; Imazawa, R.; Kubo, H.

    2018-07-01

    JT-60SA is the large Tokamak device that is being built in Japan under the Broader Approach Satellite Tokamak Programme and the Japanese National Programme and will operate as a satellite machine for ITER. The main goal of the JT-60SA Programme is to provide valuable information for the ITER steady-state scenario and for the design of DEMO, where the real-time control of the safety factor profile is very important, in connection with both MHD stability and plasma confinement. It has been demonstrated in this work that to this end polarimetry measurements are necessary, in particular in order to reconstruct the safety factor profile in reversed shear scenarios. In this paper we present the main steps of a conceptual feasibility study of a multi-channel polarimeter diagnostic and the resulting optimised geometry. In this study, magnetic scenario modelling, a realistic CAD-driven design and long-term operation requirements, rarely even considered at this stage, have been considered. It is shown that a far infrared polarimeter system, with a laser operating at a wavelength of 194.7 μm and up to twelve channels can be envisaged for JT-60SA. The top requirements can be attained, i.e., that the polarimeter, together with other diagnostic measurements, should provide q-profile reconstruction with an accuracy of 10% for the entire plasma cycle and suitable time resolution for real-time applications, in particular in high density and ITER-relevant plasma scenarios.

  9. Consumption of a high-fat soup preload leads to differences in short-term energy and fat intake between PROP non-taster and super-taster women.

    PubMed

    Shafaie, Yasmine; Hoffman, Daniel J; Tepper, Beverly J

    2015-06-01

    Taste blindness to the bitterness of PROP (6-n-propylthiouracil) has been used as a genetic marker for food selection and adiposity. We have shown that PROP non-taster (NT) women have higher BMIs and habitually consume more fat and energy than either medium-taster (MT) or super-taster (ST) women. These data imply that differences in dietary selection underlie the body weight differences among PROP taster groups. However, no studies investigated energy compensation in women classified by PROP status. We investigated if NTs would compensate less accurately for the calories and fat in a high-fat soup preload in a subsequent test meal compared to MTs and STs. Energy intake from a buffet meal was measured in 75 healthy non-diet-restrained, lean women 30 min after the ingestion of a high-fat soup preload (0.8 kcal/g; 55% calories from fat), calculated to represent 10% of resting energy expenditure for each subject, or the same volume of water. Subjects (n = 20-28/taster group) ate a standard breakfast followed 3 hr later by an ad-libitum buffet lunch, on two occasions. There were no differences in energy intake or macronutrient selection across taster groups after water. After soup, NTs consumed more energy than STs. Fat intake (as %-energy) was higher in NTs (46.4% ± 2.4) compared to either MTs (36.1 ± 1.9%) or STs (38.1% ± 2.3; p < 0.05). NTs overate by 11% ± 5 after the soup compared to MTs and STs who underrate by 16% ± 6 and 26% ± 10, respectively (p < 0.01). These data suggest that small discrepancies in short-term energy compensation and selection of fat after a mixed-nutrient, high-fat preload may play a role in positive energy balance and increased adiposity in women with the PROP non-taster phenotype. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Higher salt preference in heart failure patients.

    PubMed

    de Souza, Juli Thomaz; Matsubara, Luiz S; Menani, José Vanderlei; Matsubara, Beatriz B; Johnson, Alan Kim; De Gobbi, Juliana Irani Fratucci

    2012-02-01

    Heart failure (HF) is a complex syndrome that involves changes in behavioral, neural and endocrine regulatory systems. Dietary salt restriction along with pharmacotherapy is considered an essential component in the effective management of symptomatic HF patients. However, it is well recognized that HF patients typically have great difficulty in restricting sodium intake. We hypothesized that under HF altered activity in systems that normally function to regulate body fluid and cardiovascular homeostasis could produce an increased preference for the taste of salt. Therefore, this study was conducted to evaluate the perceived palatability (defined as salt preference) of food with different concentrations of added salt in compensated chronically medicated HF patients and comparable control subjects. Healthy volunteers (n=25) and medicated, clinically stable HF patients (n=38, NYHA functional class II or III) were interviewed and given an evaluation to assess their preferences for different amounts of saltiness. Three salt concentrations (0.58, 0.82, and 1.16 g/100 g) of bean soup were presented to the subjects. Salt preference for each concentration was quantified using an adjective scale (unpleasant, fair or delicious). Healthy volunteers preferred the soup with medium salt concentration (p=0.042), HF patients disliked the low concentration (p<0.001) and preferred the high concentration of salted bean soup (p<0.001). When compared to healthy volunteers, HF patients demonstrated a significantly greater preference for the soup with a high salt concentration (p=0.038). It is concluded that medicated, compensated patients under chronic treatment for HF have an increased preference for salt. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. Effectiveness of flavour nutrient learning and mere exposure as mechanisms to increase toddler's intake and preference for green vegetables.

    PubMed

    de Wild, Victoire W T; de Graaf, Cees; Jager, Gerry

    2013-05-01

    Children's consumption of vegetables is still below recommendations. Since preference is the most important predictor of children's intake and most children dislike vegetables, new strategies are needed to increase their preferences for vegetables. Flavour nutrient learning (FNL) could be an effective mechanism to change preferences. Forty healthy toddlers were included in a randomized intervention study. During an intervention period of 7weeks, they consumed vegetable soups (endive and spinach) twice per week. Half of the group received a high-energy variant of one soup (e.g. HE spinach) and a low energy variant of the other (LE endive), whereas for the other half the order was reversed (HE endive, LE spinach). Primary outcome measures were preference and ad libitum consumption (with a maximum of 200g) of both vegetable products (LE), measured before, shortly after the intervention period, and 2 and 6months following conditioning to assess longer-term effects. After completion of the intervention period, 28 children (14 girls and 14 boys, age 35months; SD±8.3) met criteria for FNL to occur, and were included in further data analysis. Results showed a significant increase (~58g) in ad libitum intake for both vegetable soups (stable over time), but irrespective of the energy content. This indicates a robust effect of mere exposure on intake, but no FNL. For preference, however, results showed a significant shift in liking for the vegetable soup consistently paired with high energy, supporting FNL. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Urinary Isoflavonoid Excretion is Similar after Consuming Soy Milk and Miso Soup in Japanese-American Women

    PubMed Central

    Maskarinec, Gertraud; Watts, Kirsten; Kagihara, Jamie; Hebshi, Sandra M.; Franke, Adrian A.

    2009-01-01

    Based on the hypothesis that isoflavones are absorbed more efficiently from fermented than from non-fermented soy foods, we compared the urinary isoflavonoid excretion (UIE) after intake of miso soup or soy milk. We recruited 21 women with Japanese ancestry who consumed standardized soy portions containing 48 mg isoflavones. On day 1, half the women consumed soy milk, the other half started with miso soup. On day 3, the subjects ate the other soy food and on day 5, they repeated the first food. Each participant collected a spot urine sample before and an overnight urine sample after soy food intake. All urine samples were analyzed for the daidzein, genistein, and equol using liquid chromatography-mass spectrometry and were expressed as nmol per mg creatinine. We applied mixed models to evaluate the difference in UIE by food while including the baseline values and covariates. Relative to baseline, both groups experienced significantly higher UIE after consuming any of the soy foods. We observed no significant difference in UIE when soy milk was compared to miso soup (p = 0.87) among all women or in the seven equol producers (p = 0.88). Repeated intake of the same food on different days showed high reproducibility within subjects. These preliminary results indicate similar UIEs after consuming a fermented soy food (miso) as compared to a non-fermented soy food (soy milk). Therefore, recommendations favoring fermented soy foods are not justified as long as the intestinal microflora is capable of hydrolyzing the isoflavone glucosides from non-fermented soy foods. PMID:18275624

  13. Turtle soup, Prohibition, and the population genetic structure of Diamondback Terrapins (Malaclemys terrapin).

    PubMed

    Converse, Paul E; Kuchta, Shawn R; Hauswaldt, J Susanne; Roosenburg, Willem M

    2017-01-01

    Diamondback terrapins (Malaclemys terrapin) were a popular food item in early twentieth century America, and were consumed in soup with sherry. Intense market demand for terrapin meat resulted in population declines, notably along the Atlantic seaboard. Efforts to supply terrapins to markets resulted in translocation events, as individuals were moved about to stock terrapin farms. However, in 1920 the market for turtle soup buckled with the enactment of the eighteenth amendment to the United States' Constitution-which initiated the prohibition of alcoholic drinks-and many terrapin fisheries dumped their stocks into local waters. We used microsatellite data to show that patterns of genetic diversity along the terrapin's coastal range are consistent with historical accounts of translocation and cultivation activities. We identified possible instances of human-mediated dispersal by estimating gene flow over historical and contemporary timescales, Bayesian model testing, and bottleneck tests. We recovered six genotypic clusters along the Gulf and Atlantic coasts with varying degrees of admixture, including increased contemporary gene flow from Texas to South Carolina, from North Carolina to Maryland, and from North Carolina to New York. In addition, Bayesian models incorporating translocation events outperformed stepping-stone models. Finally, we were unable to detect population bottlenecks, possibly due to translocation reintroducing genetic diversity into bottlenecked populations. Our data suggest that current patterns of genetic diversity in the terrapin were altered by the demand for turtle soup followed by the enactment of alcohol prohibition. In addition, our study shows that population genetic tools can elucidate metapopulation dynamics in taxa with complex genetic histories impacted by anthropogenic activities.

  14. Combined effects of astragalus soup and persistent Taiji boxing on improving the immunity of elderly women.

    PubMed

    Song, Qing-Hua; Xu, Rong-Mei; Zhang, Quan-Hai; Shen, Guo-Qing; Ma, Ming; Zhao, Xin-Ping; Guo, Yan-Hua; Wang, Yi

    2014-01-01

    To observe the combined effects of astragalus soup and persistent Taiji boxing on improving the immunity of women of advanced years. 120 elderly women lacking daily exercise were chosen as the study subjects. By using the table of random numbers, they were then divided into the control group and the experiment group, consisting of 60 each. The control group practiced Taiji boxing for 45 minutes twice a day. The experiment group did the same, and, in addition, took astragalus soup after each boxing. Indexes related to physical immunity of the two groups were observed and compared when they were first chosen, when the alternative treatment was applied three, six and twelve months later, respectively. The two groups demonstrated no significant differences in general data and research indexes when chosen (P > 0.05). Three months after the two groups were chosen and treated differently, the control group demonstrated no significant improvement while most indexes of the experiment group improved considerably (P > 0.05). After six months, the related indexes of both groups improved substantially (P < 0.05) and the improvement with the experiment was even clearer (P < 0.05). Twelve months later, the improvement with the experiment group was more noticeable (P < 0.01 or P < 0.05). In a relatively short period of three months, Taiji boxing produces no noticeable effect on the improvement of immunity in elderly women. However, when they resume the exercise for another three months and longer, Taiji boxing has a noticeable advantage and the effect is the most favorable when it is combined with astragalus soup.

  15. New metrics of affordable nutrition: which vegetables provide most nutrients for least cost?

    PubMed

    Drewnowski, Adam

    2013-09-01

    Measuring food prices per gram, rather than per calorie, is one way to make healthful vegetables appear less expensive. However, a better measure of affordability would take the nutrient content of vegetables into account. This study, based on analyses of US Department of Agriculture datasets, aimed to identify which vegetables, including juices and soups, provided the most nutrients per unit cost. Nutrient density was measured using the Nutrient Rich Foods (NRF) index, based on nine nutrients to encourage: protein; fiber; vitamins A, C, and E; calcium; iron; magnesium; and potassium; and on three nutrients to limit: saturated fat, added sugar, and sodium. Food cost in dollars was calculated per 100 g, per 100 kcal, per serving, and per nutrient content. One-way analyses of variance with post hoc tests were used to determine statistical significance. Results showed that tomato juices and tomato soups, dark green leafy and nonleafy vegetables, and deep yellow vegetables, including sweet potatoes, had the highest NRF scores overall. Highest NRF scores per dollar were obtained for sweet potatoes, white potatoes, tomato juices and tomato soups, carrots, and broccoli. Tomato sauces, raw tomatoes, and potato chips were eaten more frequently than were many other vegetables that were both more affordable and more nutrient-rich. These new measures of affordable nutrition can help foodservice and health professionals identify those vegetables that provide the highest nutrient density per unit cost. Processed vegetables, including soups and juices, can contribute to the quality and the affordability of the diet. Copyright © 2013 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  16. Phoenix Deepens Trenches on Mars (3D)

    NASA Technical Reports Server (NTRS)

    2008-01-01

    The Surface Stereo Imager on NASA's Phoenix Mars Lander took this anaglyph on Oct. 21, 2008, during the 145th Martian day, or sol. Phoenix landed on Mars' northern plains on May 25, 2008.

    The trench on the upper left, called 'Dodo-Goldilocks,' is about 38 centimeters (15 inches) long and 4 centimeters (1.5 inches) deep. The trench on the right, called 'Upper Cupboard,' is about 60 centimeters (24 inches) long and 3 centimeters (1 inch) deep. The trench in the lower middle is called 'Stone Soup.'

    The Phoenix mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  17. Development of a Polarimeter for Magnetic Field Measurements in the Ultraviolet

    NASA Technical Reports Server (NTRS)

    West, Edward; Porter, Jason; Davis, John; Gary, Allen; Adams, Mitzi; Rose, M. Franklin (Technical Monitor)

    2001-01-01

    This paper will describe the polarizing optics that are being developed for an ultraviolet magnetograph (SUMI) which will be flown on a sounding rocket payload. With a limited observing program, the polarizing optics were optimized to make simultaneous observation at two magnetic lines CIV (155nm) and MgII (280). This paper will give a brief overview of the SUMI instrument, will describe the polarimeter that will be used in the sounding rocket program and will present some of the measurements that have been made on the (SUMI) polarization optics.

  18. Testing of polarimeter UVP layout on telescope AZT-2

    NASA Astrophysics Data System (ADS)

    Nevodovskyi, P. V.; Vidmachenko, A. P.; Morozhenko, O. V.

    2018-05-01

    Layout of on-board small-sized ultraviolet polarimeter was created. On its basis a ground version of the layout was prepared. It was installed on the AZT-2 telescope for carrying out special tests. With this device we investigated the possibility of determining the degree of polarization of the twilight glow of the Earth's atmosphere, and also worked out the observation methodology required for such work, and the basic principles of the implementation of this method. For this purpose, a special complex of auxiliary equipment was developed.

  19. Determination of optical parameters of atmospheric particulates from ground-based polarimeter measurements

    NASA Technical Reports Server (NTRS)

    Kuriyan, J. G.; Phillips, D. H.; Willson, R. C.

    1974-01-01

    This paper describes the theoretical analysis that is required to infer, from polarimeter measurements of skylight, the size distribution, refractive index and abundance of particulates in the atmosphere. To illustrate the viability of the method, some data obtained at UCLA is analyzed and the atmospheric parameters are derived. The explicit demonstration of the redundancy in the description of aerosol distributions suggests that radiation field measurements will not uniquely determine the modal radius of the size distribution. In spite of this nonuniqueness information useful to heat budget calculations can be derived.

  20. Observations of Halley's Comet by the Solar Maximum Mission (SMM)

    NASA Technical Reports Server (NTRS)

    Niedner, M. B.

    1986-01-01

    Solar Maximum Mission coronagraph/polarimeter observations of large scale phenomena in Halley's Comet are discussed. Observations of the hydrogen coma with the UV spectrometer are considered. It is concluded that coronograph/polarimeter observations of the disconnection event, in which the entire plasma tail uproots itself from the head of the comet, is convected away in the solar wind at speeds in the 50 to 100 km/sec range (relative to the head), and is replaced by a plasma tail constructed from folding ion-tail rays, are the most interesting.

  1. Umami compounds enhance the intensity of retronasal sensation of aromas from model chicken soups.

    PubMed

    Nishimura, Toshihide; Goto, Shingo; Miura, Kyo; Takakura, Yukiko; Egusa, Ai S; Wakabayashi, Hidehiko

    2016-04-01

    We examined the influence of taste compounds on retronasal aroma sensation using a model chicken soup. The aroma intensity of a reconstituted flavour solution from which glutamic acid (Glu), inosine 5'-monophosphate (IMP), or phosphate was omitted was significantly lower (p<0.05) than that of the model soup. The aroma intensity of 0.4% NaCl solution containing the aroma chicken model (ACM) with added Glu and IMP was significantly higher (p<0.05) than that of 0.4% NaCl solution containing only ACM. The quantitative analyses showed that adding monosodium glutamate (MSG) to aqueous aroma solution containing only ACM enhanced the intensity of retronasal aroma sensation by 2.5-folds with increasing MSG concentration from 0% to 0.3%. Sensation intensity using an umami solution with added MSG and IMP was significantly higher than that with only MSG when the MSG concentration was 0.05%, 0.075%, or 0.1%. However, it plateaued when MSG concentration was beyond 0.3%. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Monosodium Glutamate Analysis in Meatballs Soup

    NASA Astrophysics Data System (ADS)

    Marlina, D.; Amran, A.; Ulianas, A.

    2018-04-01

    The analysis of monosodium glutamate (MSG) in meatball soup using Cu2+ ion as a MSG complex by UV-Vis spectrophotometry has carried out. Reaction of MSG with Cu2+ ions have formed complex compounds [Cu(C5H8NO4)2]2+ characterized by the color change of Cu2+ ion solution from light blue to dark blue. Maximum of complex absorbance [Cu(C5H8NO4)2]2+ is at 621 nm wavelength. The results showed that, the greatest condition of complex [Cu(C5H8NO4)2]2+ was at pH 10, concentration of Cu2+ 0.01 M, complex time is a 30 minute and stable for 170 minutes. Linear response and detection limit of MSG analysis with Cu2+ ions are 0.0005-0.025 M (R2 = 0.994) and (LOD) 0.0003 M. repeatability and recovery method is quite good (% RSD = 0.89% and %recovery = 93%). The analysis of MSG content in meatball soup with MSG complex method was 0.00372 M in sample A and 0.00370 M in sample B.

  3. A first study comparing preservation of a ready-to-eat soup under pressure (hyperbaric storage) at 25°C and 30°C with refrigeration.

    PubMed

    Moreira, Sílvia A; Fernandes, Pedro A R; Duarte, Ricardo; Santos, Diana I; Fidalgo, Liliana G; Santos, Mauro D; Queirós, Rui P; Delgadillo, Ivonne; Saraiva, Jorge A

    2015-11-01

    Hyperbaric storage (HS), storage under pressure at 25°C and 30°C, of a ready-to-eat (RTE) soup was studied and compared with refrigeration. Soup was stored at different time (4 and 8 h), temperature (4°C, 25°C, and 30°C), and pressure (0.1, 100, and 150 MPa) conditions, to compare microbial loads and physicochemical parameters. HS resulted in similar (microbial growth inhibition) to better (microbial inactivation) results compared to refrigeration, leading to equal and lower microbial loads, respectively, at the end of storage. Lower/higher pressure (100 vs. 150 MPa) and shorter/longer storage times (4 vs. 8 h) resulted in more pronounced microbial growth inhibition/microbial inactivation. Aerobic mesophiles showed less susceptibility to HS, compared to Enterobacteriaceae and yeast and molds. HS maintained generally the physicochemical parameters at values similar to refrigeration. Thus, HS with no need for temperature control throughout storage and so basically energetically costless, is a potential alternative to refrigeration.

  4. Nonequilibrium quantum mechanics: A "hot quantum soup" of paramagnons

    NASA Astrophysics Data System (ADS)

    Scammell, H. D.; Sushkov, O. P.

    2017-01-01

    Motivated by recent measurements of the lifetime (decay width) of paramagnons in quantum antiferromagnet TlCuCl3, we investigate paramagnon decay in a heat bath and formulate an appropriate quantum theory. Our formulation can be split into two regimes: (i) a nonperturbative, "hot quantum soup" regime where the paramagnon width is comparable to its energy; (ii) a usual perturbative regime where the paramagnon width is significantly lower than its energy. Close to the Neel temperature, the paramagnon width becomes comparable to its energy and falls into the hot quantum soup regime. To describe this regime, we develop a new finite frequency, finite temperature technique for a nonlinear quantum field theory; the "golden rule of quantum kinetics." The formulation is generic and applicable to any three-dimensional quantum antiferromagnet in the vicinity of a quantum critical point. Specifically, we apply our results to TlCuCl3 and find agreement with experimental data. Additionally, we show that logarithmic running of the coupling constant in the upper critical dimension changes the commonly accepted picture of the quantum disordered and quantum critical regimes.

  5. Field Evaluation of Australian Ration Packs. Revision of Combat Ration Ten Man,

    DTIC Science & Technology

    1987-02-01

    the pack. (iii) ’Which Rem would you most like to see added to these packs?’ & If 20% of respondents identify ’ instant noodles ’ as their most...preferred item and fewer than 10% nominate any other individual item it could be safely concluded that instant noodles will be popular. 1. Characteristics of...Sauce 1 x 11Og Tomato Sauce 1 x 11g Garlic Pdr. I x 14g Mustard 1 x 1 4g Chickn noodle Soup I x pouch Pea & Ham Soup 1 x pouch Instant Pudding (choc

  6. Spatially periodic patterns in rotating fluids: a new spin on the old "soup-can race"

    NASA Astrophysics Data System (ADS)

    Carnevali, Antonino; Carnevali, Dora; Christ, Jessica

    2000-11-01

    A student's investigation of the old "soup-can race" experiment revealed spatially periodic structures at the surface of the rotating fluid. To better observe this effect, the experiment was transferred to a test bench, where an electric motor was used to spin a cylindrical bottle, partially filled with fluids of varied densities, about its longitudinal axis. A photogate and event-counter software provided real-time measurements of the rotational frequency. Various cell-formation patterns were observed. Experimental results will be presented, and connections with the theory will be explored.

  7. Occupational Survey Report. Food Service Career Ladder AFSC 622X0

    DTIC Science & Technology

    1980-09-01

    FRY MEATS, SEAFOODS, OR POULTRY 47 G212 COOK CEREALS SUCH AS OATMEAL OR CORNMEAL 47 G209 BRAISE MEATS, SEAFOODS, OR POULTRY 47 G253 PREPARE MEATS...OATMEAL OR CORNMEAL 62 G210 BREW COFFEE OR TEA 62 G259 PREPARE SANDWICHES 61 G245 PREPARE GARNISHES 61 G260 PREPARE SOUPS 61 1341 CLEAN WORK TABLES 61 H288...EGGS FOR COOKING 80 G260 PREPARE SOUPS 80 G257 PREPARE RICE OR PASTA 80 G212 COOK CEREALS, SUCH AS OATMEAL OR CORNMEAL 77 H288 PREPARE GRIDDLES FOR USE

  8. Correction of Depolarizing Resonances in ELSA

    NASA Astrophysics Data System (ADS)

    Steier, C.; Husmann, D.

    1997-05-01

    The 3.5 GeV electron stretcherring ELSA (ELectron Stretcher Accelerator) at Bonn University is operational since 1987, both as a continuous beam facility for external fixed target experiments and as a partially dedicated synchrotron light source. For the external experiments an upgrade to polarized electrons is under way. One source of polarized electrons (GaAs crystal, photoeffect using circular polarized laser light) is operational. The studies of minimizing the losses in polarization degree due to crossing of depolarizing resonances that necessarily exist in circular accelerators (storagerings) just started recently. Calculations concerning different correction schemes for the depolarizing resonances in ELSA are presented, and first results of measurements are shown (done by means of a Møller polarimeter in one of the external beamlines).

  9. Performance characterization of UV science cameras developed for the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP)

    NASA Astrophysics Data System (ADS)

    Champey, P.; Kobayashi, K.; Winebarger, A.; Cirtain, J.; Hyde, D.; Robertson, B.; Beabout, D.; Beabout, B.; Stewart, M.

    2014-07-01

    The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras will be built and tested for flight with the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The goal of the CLASP mission is to observe the scattering polarization in Lyman-α and to detect the Hanle effect in the line core. Due to the nature of Lyman-α polarizationin the chromosphere, strict measurement sensitivity requirements are imposed on the CLASP polarimeter and spectrograph systems; science requirements for polarization measurements of Q/I and U/I are 0.1% in the line core. CLASP is a dual-beam spectro-polarimeter, which uses a continuously rotating waveplate as a polarization modulator, while the waveplate motor driver outputs trigger pulses to synchronize the exposures. The CCDs are operated in frame-transfer mode; the trigger pulse initiates the frame transfer, effectively ending the ongoing exposure and starting the next. The strict requirement of 0.1% polarization accuracy is met by using frame-transfer cameras to maximize the duty cycle in order to minimize photon noise. The CLASP cameras were designed to operate with ≤ 10 e-/pixel/second dark current, ≤ 25 e- read noise, a gain of 2.0 +- 0.5 and ≤ 1.0% residual non-linearity. We present the results of the performance characterization study performed on the CLASP prototype camera; dark current, read noise, camera gain and residual non-linearity.

  10. SELF-CALIBRATION OF COSMIC MICROWAVE BACKGROUND POLARIZATION EXPERIMENTS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keating, Brian G.; Yadav, Amit P. S.; Shimon, Meir

    2013-01-10

    Precision measurements of the polarization of the cosmic microwave background (CMB) radiation, especially experiments seeking to detect the odd-parity 'B-modes', have far-reaching implications for cosmology. To detect the B-modes generated during inflation, the flux response and polarization angle of these experiments must be calibrated to exquisite precision. While suitable flux calibration sources abound, polarization angle calibrators are deficient in many respects. Man-made polarized sources are often not located in the antenna's far-field, have spectral properties that are radically different from the CMB's, are cumbersome to implement, and may be inherently unstable over the (long) duration these searches require to detectmore » the faint signature of the inflationary epoch. Astrophysical sources suffer from time, frequency, and spatial variability, are not visible from all CMB observatories, and none are understood with sufficient accuracy to calibrate future CMB polarimeters seeking to probe inflationary energy scales of 10{sup 15} GeV. Both man-made and astrophysical sources require dedicated observations which detract from the amount of integration time usable for detection of the inflationary B-modes. CMB TB and EB modes, expected to identically vanish in the standard cosmological model, can be used to calibrate CMB polarimeters. By enforcing the observed EB and TB power spectra to be consistent with zero, CMB polarimeters can be calibrated to levels not possible with man-made or astrophysical sources. All of this can be accomplished for any polarimeter without any loss of observing time using a calibration source which is spectrally identical to the CMB B-modes.« less

  11. Development of a hard x-ray focal plane compton polarimeter: a compact polarimetric configuration with scintillators and Si photomultipliers

    NASA Astrophysics Data System (ADS)

    Chattopadhyay, T.; Vadawale, S. V.; Goyal, S. K.; Mithun, N. P. S.; Patel, A. R.; Shukla, R.; Ladiya, T.; Shanmugam, M.; Patel, V. R.; Ubale, G. P.

    2016-02-01

    X-ray polarization measurement of cosmic sources provides two unique parameters namely degree and angle of polarization which can probe the emission mechanism and geometry at close vicinity of the compact objects. Specifically, the hard X-ray polarimetry is more rewarding because the sources are expected to be intrinsically highly polarized at higher energies. With the successful implementation of Hard X-ray optics in NuSTAR, it is now feasible to conceive Compton polarimeters as focal plane detectors. Such a configuration is likely to provide sensitive polarization measurements in hard X-rays with a broad energy band. We are developing a focal plane hard X-ray Compton polarimeter consisting of a plastic scintillator as active scatterer surrounded by a cylindrical array of CsI(Tl) scintillators. The scatterer is 5 mm diameter and 100 mm long plastic scintillator (BC404) viewed by normal PMT. The photons scattered by the plastic scatterer are collected by a cylindrical array of 16 CsI(Tl) scintillators (5 mm × 5 mm × 150 mm) which are read by Si Photomultiplier (SiPM). Use of the new generation SiPMs ensures the compactness of the instrument which is essential for the design of focal plane detectors. The expected sensitivity of such polarimetric configuration and complete characterization of the plastic scatterer, specially at lower energies have been discussed in [11, 13]. In this paper, we characterize the CsI(Tl) absorbers coupled to SiPM. We also present the experimental results from the fully assembled configuration of the Compton polarimeter.

  12. On-sky performance evaluation and calibration of a polarization-sensitive focal plane array

    NASA Astrophysics Data System (ADS)

    Vorobiev, Dmitry; Ninkov, Zoran; Brock, Neal; West, Ray

    2016-07-01

    The advent of pixelated micropolarizer arrays (MPAs) has facilitated the development of polarization-sensitive focal plane arrays (FPAs) based on charge-coupled devices (CCDs) and active pixel sensors (APSs), which are otherwise only able to measure the intensity of light. Polarization sensors based on MPAs are extremely compact, light-weight, mechanically robust devices with no moving parts, capable of measuring the degree and angle of polarization of light in a single snapshot. Furthermore, micropolarizer arrays based on wire grid polarizers (so called micro-grid polarizers) offer extremely broadband performance, across the optical and infrared regimes. These devices have potential for a wide array of commercial and research applications, where measurements of polarization can provide critical information, but where conventional polarimeters could be practically implemented. To date, the most successful commercial applications of these devices are 4D Technology's PhaseCam laser interferometers and PolarCam imaging polarimeters. Recently, MPA-based polarimeters have been identified as a potential solution for space-based telescopes, where the small size, snapshot capability and low power consumption (offered by these devices) are extremely desirable. In this work, we investigated the performance of MPA-based polarimeters designed for astronomical polarimetry using the Rochester Institute of Technology Polarization Imaging Camera (RITPIC). We deployed RITPIC on the 0.9 meter SMARTS telescope at the Cerro Tololo Inter-American Observatory and observed a variety of astronomical objects (calibration stars, variable stars, reflection nebulae and planetary nebulae). We use our observations to develop calibration procedures that are unique to these devices and provide an estimate for polarimetric precision that is achievable.

  13. Search for evidence of low energy protons in solar flares

    NASA Technical Reports Server (NTRS)

    Metcalf, Thomas R.; Wuelser, Jean-Pierre; Canfield, Richard C.; Hudson, Hugh S.

    1992-01-01

    We searched for linear polarization in the H alpha line using the Stokes Polarimeter at Mees Solar Observatory and present observations of a flare from NOAA active region 6659 which began at 01:30 UT on 14 Jun. 1991. Our dataset also includes H alpha spectra from the Mees charge coupled device (MCCD) imaging spectrograph as well as hard x ray observations from the Burst and Transient Source Experiment (BATSE) instrument on board the Gamma Ray Observatory (GRO). The polarimeter scanned a 40 x 40 inch field of view using 16 raster points in a 4 x 4 grid. Each scan took about 30 seconds with 2 seconds at each raster point. The polarimeter stopped 8.5 inches between raster points and each point covered a 6 inch region. This sparse sampling increased the total field of view without reducing the temporal cadence. At each raster point, an H alpha spectrum with 20 mA spectral sampling is obtained covering 2.6 A centered on H alpha line center. The preliminary conclusions from the research are presented.

  14. Spectral line polarimetry with a channeled polarimeter.

    PubMed

    van Harten, Gerard; Snik, Frans; Rietjens, Jeroen H H; Martijn Smit, J; Keller, Christoph U

    2014-07-01

    Channeled spectropolarimetry or spectral polarization modulation is an accurate technique for measuring the continuum polarization in one shot with no moving parts. We show how a dual-beam implementation also enables spectral line polarimetry at the intrinsic resolution, as in a classic beam-splitting polarimeter. Recording redundant polarization information in the two spectrally modulated beams of a polarizing beam-splitter even provides the possibility to perform a postfacto differential transmission correction that improves the accuracy of the spectral line polarimetry. We perform an error analysis to compare the accuracy of spectral line polarimetry to continuum polarimetry, degraded by a residual dark signal and differential transmission, as well as to quantify the impact of the transmission correction. We demonstrate the new techniques with a blue sky polarization measurement around the oxygen A absorption band using the groundSPEX instrument, yielding a polarization in the deepest part of the band of 0.160±0.010, significantly different from the polarization in the continuum of 0.2284±0.0004. The presented methods are applicable to any dual-beam channeled polarimeter, including implementations for snapshot imaging polarimetry.

  15. Infrared spectro-polarimeter on the Solar Flare Telescope at NAOJ/Mitaka

    NASA Astrophysics Data System (ADS)

    Sakurai, Takashi; Hanaoka, Yoichiro; Arai, Takehiko; Hagino, Masaoki; Kawate, Tomoko; Kitagawa, Naomasa; Kobiki, Toshihiko; Miyashita, Masakuni; Morita, Satoshi; Otsuji, Ken'ichi; Shinoda, Kazuya; Suzuki, Isao; Yaji, Kentaro; Yamasaki, Takayuki; Fukuda, Takeo; Noguchi, Motokazu; Takeyama, Norihide; Kanai, Yoshikazu; Yamamuro, Tomoyasu

    2018-05-01

    An infrared spectro-polarimeter installed on the Solar Flare Telescope at the Mitaka headquarters of the National Astronomical Observatory of Japan is described. The new spectro-polarimeter observes the full Sun via slit scans performed at two wavelength bands, one near 1565 nm for a Zeeman-sensitive spectral line of Fe I and the other near 1083 nm for He I and Si I lines. The full Stokes profiles are recorded; the Fe I and Si I lines give information on photospheric vector magnetic fields, and the helium line is suitable for deriving chromospheric magnetic fields. The infrared detector we are using is an InGaAs camera with 640 × 512 pixels and a read-out speed of 90 frames s-1. The solar disk is covered by two swaths (the northern and southern hemispheres) of 640 pixels each. The final magnetic maps are made of 1200 × 1200 pixels with a pixel size of 1{^''.}8. We have been carrying out regular observations since 2010 April, and have provided full-disk, full-Stokes maps, at the rate of a few maps per day, on the internet.

  16. Extended depth measurement for a Stokes sample imaging polarimeter

    NASA Astrophysics Data System (ADS)

    Dixon, Alexander W.; Taberner, Andrew J.; Nash, Martyn P.; Nielsen, Poul M. F.

    2018-02-01

    A non-destructive imaging technique is required for quantifying the anisotropic and heterogeneous structural arrangement of collagen in soft tissue membranes, such as bovine pericardium, which are used in the construction of bioprosthetic heart valves. Previously, our group developed a Stokes imaging polarimeter that measures the linear birefringence of samples in a transmission arrangement. With this device, linear retardance and optic axis orientation; can be estimated over a sample using simple vector algebra on Stokes vectors in the Poincaré sphere. However, this method is limited to a single path retardation of a half-wave, limiting the thickness of samples that can be imaged. The polarimeter has been extended to allow illumination of narrow bandwidth light of controllable wavelength through achromatic lenses and polarization optics. We can now take advantage of the wavelength dependence of relative retardation to remove ambiguities that arise when samples have a single path retardation of a half-wave to full-wave. This effectively doubles the imaging depth of this method. The method has been validated using films of cellulose of varied thickness, and applied to samples of bovine pericardium.

  17. Theoretical and numerical evaluation of polarimeter using counter-circularly-polarized-probing-laser under the coupling between Faraday and Cotton-Mouton effect.

    PubMed

    Imazawa, Ryota; Kawano, Yasunori; Itami, Kiyoshi

    2016-04-01

    This study evaluated an effect of an coupling between the Faraday and Cotton-Mouton effect to a measurement signal of the Dodel-Kunz method which uses counter-circular-polarized probing-laser for measuring the Faraday effect. When the coupling is small (the Faraday effect is dominant and the characteristic eigenmodes are approximately circularly polarized), the measurement signal can be algebraically expressed and it is shown that the finite effect of the coupling is still significant. When the Faraday effect is not dominant, a numerical calculation is necessary. The numerical calculation under an ITER-like condition (Bt = 5.3 T, Ip = 15 MA, a = 2 m, ne = 10(20) m(-3) and λ = 119 μm) showed that difference between the pure Faraday rotation and the measurement signal of the Dodel-Kunz method was an order of one degree, which exceeds allowable error of ITER poloidal polarimeter. In conclusion, similar to other polarimeter techniques, the Dodel-Kunz method is not free from the coupling between the Faraday and Cotton-Mouton effect.

  18. The prescriptions from Shenghui soup enhanced neurite growth and GAP-43 expression level in PC12 cells.

    PubMed

    Zhang, Qi; Zhang, Zi-Jian; Wang, Xing-Hua; Ma, Jie; Song, Yue-Han; Liang, Mi; Lin, Sen-Xiang; Zhao, Jie; Zhang, Ao-Zhe; Li, Feng; Hua, Qian

    2016-09-20

    Shenghui soup is a traditional Chinese herbal medicine used in clinic for the treatment of forgetfulness. In order to understanding the prescription principle, the effects of "tonifying qi and strengthening spleen" group (TQSS) including Poria cocos (Schw.) Wolf. and Panax ginseng C.A.Mey and "eliminating phlegm and strengthening intelligence" group (EPSI) composed of Polygala tenuifolia Willd., Acorus calamus L. and Sinapis alba L from the herb complex on neurite growth in PC12 cells, two disassembled prescriptions derived from Shenghui soup and their molecular mechanisms were investigated. Firstly, CCK-8 kit was used to detect the impact of the two prescriptions on PC12 cell viability; and Flow cytometry was performed to measure the cell apoptosis when PC12 cells were treated with these drugs. Secondly, the effect of the two prescriptions on the differentiation of PC12 cells was observed. Finally, the mRNA and protein expression levels of GAP-43 were analyzed by RT-PCR and western blot, respectively. "Tonifying qi and strengthening spleen" prescription decreased cell viability in a dose-dependent manner, but had no significant effect on cell apoptosis. Meanwhile, it could improve neurite growth and elevate the mRNA and protein expression level of GAP-43. "Eliminating phlegm and strengthening intelligence" prescription also exerted the similar effects on cell viability and apoptosis. Furthermore, it could also enhance cell neurite growth, with a higher expression level of GAP-43 mRNA and protein. "Tonifying qi and strengthening spleen" and "eliminating phlegm and strengthening intelligence" prescriptions from Shenghui soup have a positive effect on neurite growth. Their effects are related to the up-regulating expression of GAP-43.

  19. Late-onset anaphylaxis due to poly (γ-glutamic acid) in the soup of commercial cold Chinese noodles in a patient with allergy to fermented soybeans (natto).

    PubMed

    Inomata, Naoko; Chin, Keishi; Nagashima, Mayumi; Ikezawa, Zenro

    2011-09-01

    Fermented soybeans (natto) have been reported to induce IgE-mediated, late-onset anaphylaxis without early-phase responses. However, the relevant allergens of natto allergy have never been identified. A 38-year-old man developed an anaphylactic reaction accompanied by flashing, generalized urticaria, conjunctival redness, and dyspnea 3 hours after ingestion of commercial cold Chinese noodles. He had avoided natto for the past year due to developing several anaphylactic reactions half a day after natto ingestion. The results of skin prick tests (SPTs) were strongly positive for natto and the soup of cold Chinese noodles. Furthermore, SPTs showed positive for poly (γ-glutamic acid) (PGA), which is a major constituent of natto mucilage, alone among all the ingredients of the cold Chinese noodle soup. Therefore, he was diagnosed with late-onset anaphylaxis to PGA contained in natto and the cold Chinese noodle soup. These results indicated that in the present case, the relevant allergen of late-onset anaphylaxis may have been PGA in all episodes and that the patient had been sensitized by PGA through natto ingestion. PGA is produced by Bacillus subtilis during fermentation and is a high-molecular, biodegradable polymer. The late onset is therefore, hypothesized to be due to a delayed absorption of PGA, as PGA biodegrades to peptides sufficiently small to be absorbed in the bowel. PGA has recently been applied to a wide range of fields such as foods, cosmetics, and medicine. Therefore, patients with late-onset anaphylaxis to PGA of natto should avoid not only natto but also other materials containing PGA.

  20. Effects of eating rate on satiety: A role for episodic memory?

    PubMed Central

    Ferriday, Danielle; Bosworth, Matthew L.; Lai, Samantha; Godinot, Nicolas; Martin, Nathalie; Martin, Ashley A.; Rogers, Peter J.; Brunstrom, Jeffrey M.

    2015-01-01

    Eating slowly is associated with a lower body mass index. However, the underlying mechanism is poorly understood. Here, our objective was to determine whether eating a meal at a slow rate improves episodic memory for the meal and promotes satiety. Participants (N = 40) consumed a 400 ml portion of tomato soup at either a fast (1.97 ml/s) or a slow (0.50 ml/s) rate. Appetite ratings were elicited at baseline and at the end of the meal (satiation). Satiety was assessed using; i) an ad libitum biscuit ‘taste test’ (3 h after the meal) and ii) appetite ratings (collected 2 h after the meal and after the ad libitum snack). Finally, to evaluate episodic memory for the meal, participants self-served the volume of soup that they believed they had consumed earlier (portion size memory) and completed a rating of memory ‘vividness’. Participants who consumed the soup slowly reported a greater increase in fullness, both at the end of the meal and during the inter-meal interval. However, we found little effect of eating rate on subsequent ad libitum snack intake. Importantly, after 3 h, participants who ate the soup slowly remembered eating a larger portion. These findings show that eating slowly promotes self-reported satiation and satiety. For the first time, they also suggest that eating rate influences portion size memory. However, eating slowly did not affect ratings of memory vividness and we found little evidence for a relationship between episodic memory and satiety. Therefore, we are unable to conclude that episodic memory mediates effects of eating rate on satiety. PMID:26143189

  1. A cross-cultural study of acceptability and food pairing for hot sauces.

    PubMed

    Kim, Hyun-Jee; Chung, Seo-Jin; Kim, Kwang-Ok; Nielsen, Belinda; Ishii, Rie; O'Mahony, Michael

    2018-04-01

    This study was conducted to understand the acceptance levels of hot sauces among consumers from different culinary cultures. Two newly developed hot sauces [fermented red chili pepper with soybean-paste-based sauce(GS) and fermented red chili-pepper-based sauce(KS)] were compared with Tabasco sauce(TB) and Sriracha sauce(SR). Two separate cross-cultural home-use tests(HUTs) were conducted: pizza and cream soup were provided as food items in HUT 1, whereas grilled chicken wings and rice noodle soup were provided in HUT 2. Consumers residing in Denmark, South Korea, and US participated in each HUT (n≅100 per country). Acceptance levels and the reasons for (dis)liking particular hot sauces applied to food systems were assessed. The food items that paired well with different hot sauces when the sauces were applied freely to regular meals were also analyzed among the US and Korean subjects. When the hot-sauce samples were applied to pizza and cream soup, the preferred order of the samples exhibited a cross-cultural agreement (GS = KS > TB). In the case of grilled chicken and rice noodle soup, the acceptance rating was similar for the three types of hot sauces among Koreans, whereas the acceptance was higher for SR among the US subjects for both foodstuffs, while Danish subjects preferred GS and KS over SR. The US subjects did not like hot-sauce samples with sweet and weak spiciness, whereas the Korean and Danish subjects disliked the hot-sauce sample when it was too spicy and not sufficiently sweet. These findings indicate that the matching of particular sauces with specific food items is culture-dependent, and this needs to be considered when trying to export food products such as hot sauce to other countries. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Maternal Dietary Patterns and Fetal Growth: A Large Prospective Cohort Study in China.

    PubMed

    Lu, Min-Shan; Chen, Qiao-Zhu; He, Jian-Rong; Wei, Xue-Ling; Lu, Jin-Hua; Li, Sheng-Hui; Wen, Xing-Xuan; Chan, Fan-Fan; Chen, Nian-Nian; Qiu, Lan; Mai, Wei-Bi; Zhang, Rui-Fang; Hu, Cui-Yue; Xia, Hui-Min; Qiu, Xiu

    2016-04-28

    There was limited evidence revealing the association of Chinese maternal dietary patterns with fetal growth. We aimed to examine the relationship of maternal dietary patterns during pregnancy to neonatal birth weight and birth weight for gestational age in a Chinese population. A total of 6954 mother-child pairs were included from the Born in Guangzhou Cohort Study. Maternal diet during pregnancy was assessed using a self-administered food frequency questionnaire. Cluster analysis was used to identify dietary patterns. The following six dietary patterns were identified: "Cereals, eggs, and Cantonese soups" (n 1026, 14.8%), "Dairy" (n 1020, 14.7%), "Fruits, nuts, and Cantonese desserts" (n 799, 11.5%), "Meats" (n 1066, 15.3%), "Vegetables" (n 1383, 19.9%), and "Varied" (n 1224, 17.6%). The mean neonatal birth weight Z scores of women in the above patterns were 0.02, 0.07, 0.20, 0.01, 0.06, and 0.14, respectively. Women in the "Fruits, nuts, and Cantonese desserts" and "Varied" groups had significantly heavier infants compared with those in the "Cereals, eggs, and Cantonese soups" group. Compared with women in the "Cereals, eggs, and Cantonese soups" group, those in the "Varied" group had marginally significantly lower odds of having a small-for-gestational age (SGA) infant after adjustment for other confounders (OR 0.77, 95% CI 0.57, 1.04, p = 0.08). These findings suggest that compared to a traditional Cantonese diet high in cereals, eggs, and Cantonese soups, a diet high in fruits, nuts, and Cantonese desserts might be associated with a higher birth weight, while a varied diet might be associated with a greater birth weight and also a decreased risk of having a SGA baby.

  3. Effects of eating rate on satiety: A role for episodic memory?

    PubMed

    Ferriday, Danielle; Bosworth, Matthew L; Lai, Samantha; Godinot, Nicolas; Martin, Nathalie; Martin, Ashley A; Rogers, Peter J; Brunstrom, Jeffrey M

    2015-12-01

    Eating slowly is associated with a lower body mass index. However, the underlying mechanism is poorly understood. Here, our objective was to determine whether eating a meal at a slow rate improves episodic memory for the meal and promotes satiety. Participants (N=40) consumed a 400ml portion of tomato soup at either a fast (1.97ml/s) or a slow (0.50ml/s) rate. Appetite ratings were elicited at baseline and at the end of the meal (satiation). Satiety was assessed using; i) an ad libitum biscuit 'taste test' (3h after the meal) and ii) appetite ratings (collected 2h after the meal and after the ad libitum snack). Finally, to evaluate episodic memory for the meal, participants self-served the volume of soup that they believed they had consumed earlier (portion size memory) and completed a rating of memory 'vividness'. Participants who consumed the soup slowly reported a greater increase in fullness, both at the end of the meal and during the inter-meal interval. However, we found little effect of eating rate on subsequent ad libitum snack intake. Importantly, after 3h, participants who ate the soup slowly remembered eating a larger portion. These findings show that eating slowly promotes self-reported satiation and satiety. For the first time, they also suggest that eating rate influences portion size memory. However, eating slowly did not affect ratings of memory vividness and we found little evidence for a relationship between episodic memory and satiety. Therefore, we are unable to conclude that episodic memory mediates effects of eating rate on satiety. Copyright © 2015. Published by Elsevier Inc.

  4. Development of two color laser diagnostics for the ITER poloidal polarimeter.

    PubMed

    Kawahata, K; Akiyama, T; Tanaka, K; Nakayama, K; Okajima, S

    2010-10-01

    Two color laser diagnostics using terahertz laser sources are under development for a high performance operation of the Large Helical Device and for future fusion devices such as ITER. So far, we have achieved high power laser oscillation lines simultaneously oscillating at 57.2 and 47.7 μm by using a twin optically pumped CH(3)OD laser, and confirmed the original function, compensation of mechanical vibration, of the two color laser interferometer. In this article, application of the two color laser diagnostics to the ITER poloidal polarimeter and recent hardware developments will be described.

  5. Polarization characterization of an LCTV with a Mueller matrix imaging polarimeter

    NASA Astrophysics Data System (ADS)

    Pezzaniti, J. Larry; Chipman, Russell A.; Gregory, Don A.

    1993-10-01

    The polarization properties of a TVT-6000 LCTV have been investigated. Mueller matrices of multiple ray paths through the TVT-6000 were measured for a single (typical) pixel, and through several pixels, using an imaging polarimeter. The TVT-6000 was characterized as a function of applied voltage and angle of incidence. From the Mueller matrices, the spatially dependent retardance, diattenuation, and depolarization are calculated and displayed as topographic maps. In another set of measurements, the LCTV is illuminated with a plane wave, and the spatial distribution of polarization in the Far Field Diffraction Pattern is measured in Mueller matrix form.

  6. Total elimination of sampling errors in polarization imagery obtained with integrated microgrid polarimeters.

    PubMed

    Tyo, J Scott; LaCasse, Charles F; Ratliff, Bradley M

    2009-10-15

    Microgrid polarimeters operate by integrating a focal plane array with an array of micropolarizers. The Stokes parameters are estimated by comparing polarization measurements from pixels in a neighborhood around the point of interest. The main drawback is that the measurements used to estimate the Stokes vector are made at different locations, leading to a false polarization signature owing to instantaneous field-of-view (IFOV) errors. We demonstrate for the first time, to our knowledge, that spatially band limited polarization images can be ideally reconstructed with no IFOV error by using a linear system framework.

  7. Upgraded photon calorimeter with integrating readout for Hall A Compton Polarimeter at Jefferson Lab

    DOE PAGES

    Friend, M.; Parno, D.; Benmokhtar, F.; ...

    2012-06-01

    The photon arm of the Compton polarimeter in Hall A of Jefferson Lab has been upgraded to allow for electron beam polarization measurements with better than 1% accuracy. The data acquisition system (DAQ) now includes an integrating mode, which eliminates several systematic uncertainties inherent in the original counting-DAQ setup. The photon calorimeter has been replaced with a Ce-doped Gd 2SiO 5 crystal, which has a bright output and fast response, and works well for measurements using the new integrating method at electron beam energies from 1 to 6 GeV.

  8. A graphite crystal polarimeter for stellar X-ray astronomy.

    NASA Technical Reports Server (NTRS)

    Weisskopf, M. C.; Berthelsdorf, R.; Epstein, G.; Linke, R.; Mitchell, D.; Novick, R.; Wolff, R. S.

    1972-01-01

    The first crystal X-ray polarimeter to be used for X-ray astronomy is described. Polarization is measured by modulation of the X rays diffracted at an average 45 deg glancing angle from large, curved graphite crystal panels as these rotate about an axis parallel to the incident X-ray flux. Arrangement of the crystal panels, the design of the detector, and the signal-processing circuitry were optimized to minimize systematic effects produced by off-axis pointing of the rocket and cosmic ray induced events. The in-flight performance of the instrument in relation to the observed background signal is discussed.

  9. Monte-Carlo Estimation of the Inflight Performance of the GEMS Satellite X-Ray Polarimeter

    NASA Technical Reports Server (NTRS)

    Kitaguchi, Takao; Tamagawa, Toru; Hayato, Asami; Enoto, Teruaki; Yoshikawa, Akifumi; Kaneko, Kenta; Takeuchi, Yoko; Black, Kevin; Hill, Joanne; Jahoda, Keith; hide

    2014-01-01

    We report a Monte-Carlo estimation of the in-orbit performance of a cosmic X-ray polarimeter designed to be installed on the focal plane of a small satellite. The simulation uses GEANT for the transport of photons and energetic particles and results from Magboltz for the transport of secondary electrons in the detector gas. We validated the simulation by comparing spectra and modulation curves with actual data taken with radioactive sources and an X-ray generator. We also estimated the in-orbit background induced by cosmic radiation in low Earth orbit.

  10. Monte-Carlo estimation of the inflight performance of the GEMS satellite x-ray polarimeter

    NASA Astrophysics Data System (ADS)

    Kitaguchi, Takao; Tamagawa, Toru; Hayato, Asami; Enoto, Teruaki; Yoshikawa, Akifumi; Kaneko, Kenta; Takeuchi, Yoko; Black, Kevin; Hill, Joanne; Jahoda, Keith; Krizmanic, John; Sturner, Steven; Griffiths, Scott; Kaaret, Philip; Marlowe, Hannah

    2014-07-01

    We report a Monte-Carlo estimation of the in-orbit performance of a cosmic X-ray polarimeter designed to be installed on the focal plane of a small satellite. The simulation uses GEANT for the transport of photons and energetic particles and results from Magboltz for the transport of secondary electrons in the detector gas. We validated the simulation by comparing spectra and modulation curves with actual data taken with radioactive sources and an X-ray generator. We also estimated the in-orbit background induced by cosmic radiation in low Earth orbit.

  11. May turbulence and fossil turbulence lead to life in the universe?

    NASA Astrophysics Data System (ADS)

    Gibson, Carl H.

    2013-01-01

    Turbulence is defined as an eddy-like state of fluid motion where the inertial-vortex forces of the eddies are larger than all the other forces that tend to damp the eddies out. Fossil turbulence is a perturbation produced by turbulence that persists after the fluid ceases to be turbulent at the scale of the perturbation. Because vorticity is produced at small scales, turbulence cascades from small scales to large, providing a consistent physical basis for Kolmogorovian universal similarity laws. Oceanic and astrophysical mixing and diffusion are dominated by fossil turbulence and fossil turbulent waves. Observations from space telescopes show turbulence existed in the beginning of the universe and that its fossils still persist. Fossils of big bang turbulence include a preferred large-scale spin direction, large scale microwave temperature anisotropy patterns, and the dominant dark matter of all galaxies; that is, clumps of ~10^12 frozen hydrogen earth-mass planets that make stars and globular-star-clusters when gravitationally agitated. When the planets were hot gas, we can speculate that they hosted the formation of the first life in a seeded cosmic organic-chemical soup of hot- water oceans as planets merged to form and over-feed the first stars.

  12. Turbulence and fossil turbulence lead to life in the universe

    NASA Astrophysics Data System (ADS)

    Gibson, Carl H.

    2013-07-01

    Turbulence is defined as an eddy-like state of fluid motion where the inertial-vortex forces of the eddies are larger than all the other forces that tend to damp the eddies out. Fossil turbulence is a perturbation produced by turbulence that persists after the fluid ceases to be turbulent at the scale of the perturbation. Because vorticity is produced at small scales, turbulence must cascade from small scales to large, providing a consistent physical basis for Kolmogorovian universal similarity laws. Oceanic and astrophysical mixing and diffusion are dominated by fossil turbulence and fossil turbulent waves. Observations from space telescopes show turbulence and vorticity existed in the beginning of the universe and that their fossils persist. Fossils of big bang turbulence include spin and the dark matter of galaxies: clumps of ∼1012 frozen hydrogen planets that make globular star clusters as seen by infrared and microwave space telescopes. When the planets were hot gas, they hosted the formation of life in a cosmic soup of hot-water oceans as they merged to form the first stars and chemicals. Because spontaneous life formation according to the standard cosmological model is virtually impossible, the existence of life falsifies the standard cosmological model.

  13. Turbulence and Fossil Turbulence lead to Life in the Universe

    NASA Astrophysics Data System (ADS)

    Gibson, Carl H.

    2012-03-01

    Turbulence is defined as an eddy-like state of fluid motion where the inertial-vortex forces of the eddies are larger than all the other forces that tend to damp the eddies out. Fossil turbulence is a perturbation produced by turbulence that persists after the fluid ceases to be turbulent at the scale of the perturbation. Because vorticity is produced at small scales, turbulence must cascade from small scales to large, providing a consistent physical basis for Kolmogorovian universal similarity laws. Oceanic and astrophysical mixing and diffusion are dominated by fossil turbulence and fossil turbulent waves. Observations from space telescopes show turbulence and vorticity existed in the beginning of the universe and that their fossils persist. Fossils of big bang turbulence include spin and the dark matter of galaxies: clumps of ~ 1012 frozen hydrogen planets that make globular star clusters as seen by infrared and microwave space telescopes. When the planets were hot gas, they hosted the formation of life in a cosmic soup of hot- water oceans as they merged to form the first stars and chemicals. Because spontaneous life formation according to the standard cosmological model is virtually impossible, the existence of life falsifies the standard cosmological model.

  14. Polarimetric survey of main-belt asteroids. VI. New results from the second epoch of the CASLEO survey

    NASA Astrophysics Data System (ADS)

    Gil-Hutton, R.; García-Migani, E.

    2017-11-01

    Aims: We present the results of a polarimetric survey of main-belt asteroids at Complejo Astronómico El Leoncito (CASLEO), San Juan, Argentina. The aims of this survey are to increase the database of asteroid polarimetry and to estimate the diversity in the polarimetric properties of asteroids that belong to different taxonomic classes. Methods: The data were obtained using the CASPOL polarimeter at the 2.15 m telescope. CASPOL is a polarimeter based on a CCD detector and a Savart plate. The survey began in 1995 and data on a large sample of asteroids were obtained until 2012. A second period began in 2013 using a polarimeter with a more sensitive detector in order to study small asteroids, families, and special taxonomic groups. Results: We present and analyze the unpublished results for 128 asteroids of different taxonomic types, 55 of them observed for the first time. The observational data allowed us to find probable new cases of Barbarian objects but also two D-type objects, (565) Marbachia and (1481) Tubingia, that seem to have phase-polarization curves with a large inversion angle. The data obtained combined with data from the literature enabled us to find phase-polarization curves for 121 objects of different taxonomic types and to study the relations between several polarimetric and physical parameters. Using an approximation for the phase-polarization curve we found the index of refraction of the surface material and the scatter separation distance for all the objects with known polarimetric parameters. We also found that the inversion angle is a function of the index of refraction of the surface, while the phase angle where the minimum of polarization is produced provides information about the distance between scatter particles or, to some extent, the porosity of the surface. Based on observations carried out at the Complejo Astronómico El Leoncito, operated under agreement between the Consejo Nacional de Investigaciones Científicas y Técnicas de la República Argentina and the National Universities of La Plata, Córdoba, and San Juan.Tables 1 and 2 are only available at the CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (http://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/607/A103

  15. Optimization of the GRAPE Polarimeter Design

    NASA Astrophysics Data System (ADS)

    McConnell, Mark

    The Gamma Ray Polarimeter Experiment (GRAPE) is designed to investigate one of the most exotic phenomena in the universe - gamma-ray bursts (GRB). There has been intense observational and theoretical research in recent years, but research in this area has been largely focused on studies of time histories, spectra, and spatial distributions. Theoretical models show that a more complete understanding of the inner structure of GRBs, including the geometry and physical processes close to the central engine, requires the exploitation of gamma-ray polarimetry. Over the past several years, we have developed the GRAPE instrument to measure the polarization of gamma-rays from GRBs over the energy range of 50 to 500 keV. The GRAPE design is a modular one in which several independent modules are required to achieve sufficient sensitivity. A single module fits on the front end of a 2-inch square flat-panel multi-anode photomultiplier tube (MAPMT). The first operational balloon flight took in place in September of 2011 from Ft. Sumner, NM. The purpose of the 2011 flight was to validate the science capability of GRAPE by measuring the Crab polarization with a collimated array of 16 modules. The limited success of that flight led to a second validation flight (also from Ft. Sumner) in the fall of 2014, with significantly improved shielding and a larger array of modules. That flight proved too short to make a full observation of the Crab. Although we did not succeed in measuring the polarization of the Crab with a high degree of confidence, we feel that we are nonetheless prepared to move forward with our program. Our next goal is to fly GRAPE on a long duration balloon (LDB) platform to collect data on a significant sample of GRBs. Our experience with the first two balloon flights, coupled with further design efforts focused on orbital payloads, has led to an improved polarimeter concept that represents a natural evolution of the current design. It is this new concept that we are now proposing to develop and test before embarking on a long-duration balloon program. This new design, with improved sensitivity, will ensure that the science objectives can be achieved within the context of a viable balloon program.

  16. [Application of surface-enhanced Raman spectra to the analysis of Chinese Ephedra soup medicines].

    PubMed

    Zhang, J; Wang, Y

    1998-06-01

    A new method was developed to analyse the spectra of ephedrine in Chinese ephedra soup medicines, using surface-enhanced technique to combine thin layer chromatographic (TLC) technique with surface-enhanced Raman spectroscopy (SERS). The study indicates that the main vibrant characteristic spec tral band of the ephedrine molecules can be obtained by TLC in the samples of about 8 microg, and expounds char acteristics of the sample molecules and the silica gel. Therefore, it is clarified that the main chemical composi tion of Chinese medicines can be carried as finger-print type appraisal by combining TLC and SERS.

  17. Large-scale horizontal flows from SOUP observations of solar granulation

    NASA Technical Reports Server (NTRS)

    November, L. J.; Simon, G. W.; Tarbell, T. D.; Title, A. M.; Ferguson, S. H.

    1987-01-01

    Using high resolution time sequence photographs of solar granulation from the SOUP experiment on Spacelab 2, large scale horizontal flows were observed in the solar surface. The measurement method is based upon a local spatial cross correlation analysis. The horizontal motions have amplitudes in the range 300 to 1000 m/s. Radial outflow of granulation from a sunspot penumbra into surrounding photosphere is a striking new discovery. Both the supergranulation pattern and cellular structures having the scale of mesogranulation are seen. The vertical flows that are inferred by continuity of mass from these observed horizontal flows have larger upflow amplitudes in cell centers than downflow amplitudes at cell boundaries.

  18. Evolution of specific 3'-5'-linkages in RNA in pre-biotic soup: a new hypothesis.

    PubMed

    Kumar, Vaijayanti A

    2016-11-02

    This article reviews the different possibilities towards progression of the formation of DNA/RNA in the chemical world, before life, in enzyme-free conditions. The advent of deoxyribo- and ribopentose-sugars, nucleosides, nucleotides and oligonucleotides in the prebiotic soup is briefly discussed. Further, the formation of early single stranded oligomers, base-pairing possibilities and information transfer based on the stability parameters of the derived duplexes is reviewed. Each theory has its own merits and demerits which we have elaborated upon. Lastly, using clues from this literature, a possible explanation for the specific 3'-5'-linkages in RNA is proposed.

  19. Simple Recipes for Prebiotic Soup: A High School or Undergraduate Chemistry Laboratory

    NASA Astrophysics Data System (ADS)

    Martinez-Meeler, Marisol; Aljinovic, Nika; Swain, Dorothy

    2003-06-01

    A lab activity demonstrating Stanley Miller‘s prebiotic soup experiments is described. This lab activity, which uses only simple, readily available materials and equipment, would be suitable for use in a high school or introductory college chemistry class. The activity starts by asking students to consider some of the debated issues surrounding research into the chemical origins of life on Earth. It continues by having the students set up a simple apparatus that sends an electrical spark through a mixture of methane, ammonia, and water. The experiment concludes (the following week) by having students analyze their reaction products and design their own variation on the experiment.

  20. The Spectrum Orbit Utilization Program (SOUP) used for DBS plan analysis at RARC '83

    NASA Technical Reports Server (NTRS)

    Davidson, J.; Ottey, H. R.; Sawitz, P.; Zusman, F. S.

    1985-01-01

    This paper describes the history, functions, and usage of the program that was used to analyze the plans for direct broadcast satellite service developed in the course of the 1983 Regional Administrative Radio Conference for ITU Region 2. Given the requirements for direct broadcast service by the administrations, the conference delegates (1) developed the appropriate technical parameters; (2) made tentative assignments to the orbit locations, frequencies, and polarizations of space stations, (3) calculated the interferences and margins of such assignments through the use of the Spectrum Orbit Utilization Program (SOUP); and (4) iterated this procedure until an acceptable plan was found.

  1. The role of medium radiation dose on microbiological safety and shelf-life of some traditional soups

    NASA Astrophysics Data System (ADS)

    Irawati, Z.; Natalia, L.; Nurcahya, C. M.; Anas, F.

    2007-11-01

    Irradiation at medium doses in combination with cryogenic condition along the process to ensure the safety, quality and to extend the shelf-life of prepared meals have been investigated. Semi-concentrated black, ox-tail, chicken vegetable and chicken sweet corn soups were individually packed in a dry laminate pouch of PET 12 μ/LDPE adh.2 μ/Al-foil 7 μ/LDPE adh/LLDPE (C 4) 50 μ under vacuum followed by freezing for 24 h at -18 °C prior to irradiation with doses of 1, 3, 5 and 7 kGy at cryogenic condition (-79 °C), respectively. Both the non-irradiated and irradiated prepared meals were then stored in refrigerator at 5±2 °C. Non-irradiated and the irradiated samples at 1 kGy were mostly damaged after a week of storage. Gamma irradiation at doses of 5-7 kGy for the soups could reduce microbial load by about 2-3 log cycles, respectively, without affecting the physical-chemical parameters and palatability within 2-3 months while the unirradiated samples could only withstand for 1 month storage time.

  2. Performance Characterization of UV Science Cameras Developed for the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP)

    NASA Technical Reports Server (NTRS)

    Champey, Patrick; Kobayashi, Ken; Winebarger, Amy; Cirtin, Jonathan; Hyde, David; Robertson, Bryan; Beabout, Brent; Beabout, Dyana; Stewart, Mike

    2014-01-01

    The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras will be built and tested for flight with the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The goal of the CLASP mission is to observe the scattering polarization in Lyman-alpha and to detect the Hanle effect in the line core. Due to the nature of Lyman-alpha polarization in the chromosphere, strict measurement sensitivity requirements are imposed on the CLASP polarimeter and spectrograph systems; science requirements for polarization measurements of Q/I and U/I are 0.1% in the line core. CLASP is a dual-beam spectro-polarimeter, which uses a continuously rotating waveplate as a polarization modulator, while the waveplate motor driver outputs trigger pulses to synchronize the exposures. The CCDs are operated in frame-transfer mode; the trigger pulse initiates the frame transfer, effectively ending the ongoing exposure and starting the next. The strict requirement of 0.1% polarization accuracy is met by using frame-transfer cameras to maximize the duty cycle in order to minimize photon noise. Coating the e2v CCD57-10 512x512 detectors with Lumogen-E coating allows for a relatively high (30%) quantum efficiency at the Lyman-$\\alpha$ line. The CLASP cameras were designed to operate with =10 e- /pixel/second dark current, = 25 e- read noise, a gain of 2.0 and =0.1% residual non-linearity. We present the results of the performance characterization study performed on the CLASP prototype camera; dark current, read noise, camera gain and residual non-linearity.

  3. Performance Characterization of UV Science Cameras Developed for the Chromospheric Lyman-Alpha Spectro-Polarimeter

    NASA Technical Reports Server (NTRS)

    Champey, P.; Kobayashi, K.; Winebarger, A.; Cirtain, J.; Hyde, D.; Robertson, B.; Beabout, D.; Beabout, B.; Stewart, M.

    2014-01-01

    The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras will be built and tested for flight with the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The goal of the CLASP mission is to observe the scattering polarization in Lyman-alpha and to detect the Hanle effect in the line core. Due to the nature of Lyman-alpha polarization in the chromosphere, strict measurement sensitivity requirements are imposed on the CLASP polarimeter and spectrograph systems; science requirements for polarization measurements of Q/I and U/I are 0.1 percent in the line core. CLASP is a dual-beam spectro-polarimeter, which uses a continuously rotating waveplate as a polarization modulator, while the waveplate motor driver outputs trigger pulses to synchronize the exposures. The CCDs are operated in frame-transfer mode; the trigger pulse initiates the frame transfer, effectively ending the ongoing exposure and starting the next. The strict requirement of 0.1 percent polarization accuracy is met by using frame-transfer cameras to maximize the duty cycle in order to minimize photon noise. Coating the e2v CCD57-10 512x512 detectors with Lumogen-E coating allows for a relatively high (30 percent) quantum efficiency at the Lyman-alpha line. The CLASP cameras were designed to operate with 10 e-/pixel/second dark current, 25 e- read noise, a gain of 2.0 +/- 0.5 and 1.0 percent residual non-linearity. We present the results of the performance characterization study performed on the CLASP prototype camera; dark current, read noise, camera gain and residual non-linearity.

  4. Space- and Ground-based Coronal Spectro-Polarimetry

    NASA Astrophysics Data System (ADS)

    Fineschi, Silvano; Bemporad, Alessandro; Rybak, Jan; Capobianco, Gerardo

    This presentation gives an overview of the near-future perspectives of ultraviolet and visible-light spectro-polarimetric instrumentation for probing coronal magnetism from space-based and ground-based observatories. Spectro-polarimetric imaging of coronal emission-lines in the visible-light wavelength-band provides an important diagnostics tool of the coronal magnetism. The interpretation in terms of Hanle and Zeeman effect of the line-polarization in forbidden emission-lines yields information on the direction and strength of the coronal magnetic field. As study case, this presentation will describe the Torino Coronal Magnetograph (CorMag) for the spectro-polarimetric observation of the FeXIV, 530.3 nm, forbidden emission-line. CorMag - consisting of a Liquid Crystal (LC) Lyot filter and a LC linear polarimeter - has been recently installed on the Lomnicky Peak Observatory 20cm Zeiss coronagraph. The preliminary results from CorMag will be presented. The linear polarization by resonance scattering of coronal permitted line-emission in the ultraviolet (UV)can be modified by magnetic fields through the Hanle effect. Space-based UV spectro-polarimeters would provide an additional tool for the disgnostics of coronal magnetism. As a case study of space-borne UV spectro-polarimeters, this presentation will describe the future upgrade of the Sounding-rocket Coronagraphic Experiment (SCORE) to include the capability of imaging polarimetry of the HI Lyman-alpha, 121.6 nm. SCORE is a multi-wavelength imager for the emission-lines, HeII 30.4 nm and HI 121.6 nm, and visible-light broad-band emission of the polarized K-corona. SCORE has flown successfully in 2009. This presentation will describe how in future re-flights SCORE could observe the expected Hanle effect in corona with a HI Lyman-alpha polarimeter.

  5. Coronal multichannel polarimeter for Lomnický štít Observatory. (Slovak Title: Koronálny multikanálový polarimeter pre observatórium Lomnický štít)

    NASA Astrophysics Data System (ADS)

    Rybák, J.; Ambróz, J.; Gömöry, P.; Kozák, M.; Kučera, A.; Tomczyk, S.; Sewell, S.; Summers, R.; Sutherland, L.; Watt, A.

    2010-12-01

    The contribution presents the process of development and preparation of the Coronal Multi-channel Polarimeter (COMP-S) for the Lomnický štít Observatory of the SAS Astronomy Institute. The design of the device is based on the experience gained in recent years with the CoMP (High Altitude Observatory / NCAR; Boulder, USA) instrument. The device will be a combination of two main optical components: the Lyot tunable filter and polarimeter, and is prepared specifically for one of the 20 cm Zeiss coronagraph at the Lomnický štít Observatory where it will be installed in 2011. CoMP-S will differ from its predecessor in several respects. The most important difference is that CoMP-S will be able to observe the corona and chromospheric emission lines in the wavelength range from 530 to 1083 nm. This feature will be achieved using superachromatic wave plates and dichroic polarizers with wide bandwidth. Furthermore, in the CoMP-S instrument new SWIFT liquid crystals of Meadowlark Optics company will be used as variable retarders instead of nematic liquid crystal retarders (LCVR) which will considerably shorten the measuring process. Ferroelectric liquid crystals will provide measurements of the full Stokes vector with nearly optimal polarization throughout the whole instrument bandwidth. Recently developed sCMOS cameras are to provide diffraction limit resolution of observations, with the 860x680 arc second field and 30-frames-per-second cadence. The device will be used in the Astronomical Observatory of SAS at Lomnický štít primarily for spectrum polarimetry of prominences and coronal loops of the active solar regions.

  6. Polarimeter Arrays for Cosmic Microwave Background Measurements

    NASA Technical Reports Server (NTRS)

    Stevenson, Thomas; Cao, Nga; Chuss, David; Fixsen, Dale; Hsieh, Wen-Ting; Kogut, Alan; Limon, Michele; Moseley, S. Harvey; Phillips, Nicholas; Schneider, Gideon

    2006-01-01

    We discuss general system architectures and specific work towards precision measurements of Cosmic Microwave Background (CMB) polarization. The CMB and its polarization carry fundamental information on the origin, structure, and evolution of the universe. Detecting the imprint of primordial gravitational radiation on the faint polarization of the CMB will be difficult. The two primary challenges will be achieving both the required sensitivity and precise control over systematic errors. At anisotropy levels possibly as small as a few nanokelvin, the gravity-wave signal is faint compared to the fundamental sensitivity limit imposed by photon arrival statistics, and one must make simultaneous measurements with large numbers, hundreds to thousands, of independent background-limited direct detectors. Highly integrated focal plane architectures, and multiplexing of detector outputs, will be essential. Because the detectors, optics, and even the CMB itself are brighter than the faint gravity-wave signal by six to nine orders of magnitude, even a tiny leakage of polarized light reflected or diffracted from warm objects could overwhelm the primordial signal. Advanced methods of modulating only the polarized component of the incident radiation will play an essential role in measurements of CMB polarization. One promising general polarimeter concept that is under investigation by a number of institutions is to first use planar antennas to separate millimeter-wave radiation collected by a lens or horn into two polarization channels. Then the signals can be fed to a pair of direct detectors through a planar circuit consisting of superconducting niobium microstrip transmission lines, hybrid couplers, band-pass filters, and phase modulators to measure the Stokes parameters of the incoming radiation.

  7. The science case of the PEPSI high-resolution echelle spectrograph and polarimeter for the LBT

    NASA Astrophysics Data System (ADS)

    Strassmeier, K. G.; Pallavicini, R.; Rice, J. B.; Andersen, M. I.

    2004-05-01

    We lay out the scientific rationale for and present the instrumental requirements of a high-resolution adaptive-optics Echelle spectrograph with two full-Stokes polarimeters for the Large Binocular Telescope (LBT) in Arizona. Magnetic processes just like those seen on the Sun and in the space environment of the Earth are now well recognized in many astrophysical areas. The application to other stars opened up a new field of research that became widely known as the solar-stellar connection. Late-type stars with convective envelopes are all affected by magnetic processes which give rise to a rich variety of phenomena on their surface and are largely responsible for the heating of their outer atmospheres. Magnetic fields are likely to play a crucial role in the accretion process of T-Tauri stars as well as in the acceleration and collimation of jet-like flows in young stellar objects (YSOs). Another area is the physics of active galactic nucleii (AGNs) , where the magnetic activity of the accreting black hole is now believed to be responsible for most of the behavior of these objects, including their X-ray spectrum, their notoriously dramatic variability, and the powerful relativistic jets they produce. Another is the physics of the central engines of cosmic gamma-ray bursts, the most powerful explosions in the universe, for which the extreme apparent energy release are explained through the collimation of the released energy by magnetic fields. Virtually all the physics of magnetic fields exploited in astrophysics is somehow linked to our understanding of the Sun's and the star's magnetic fields.

  8. Comparison of two data acquisition and processing systems of Moller polarimeter in Hall A of Jefferson Lab

    DOE PAGES

    Vereshchaka, Vadym V.; Glamazdin, Oleksandr V.; Pomatsalyuk, Roman I.

    2014-07-01

    Two data acquisition and processing systems are used simultaneously to measure electron beam polarization by Moller polarimeter in Hall A of Jefferson Lab (Newport News, VA, USA). The old system (since 1997) is fully functional, but is not repairable in case of malfunction (system modules arenot manufactured anymore). The new system (since 2010) based on flash-ADC is more accurate, but currently requires more detailed adjustment and further improvement. Description and specifications of two data acquisition and processing systems have been given. The results of polarization measurements during experiments conducted in Hall A from 2010 to 2012 are compared.

  9. Development and characterization of a snapshot Mueller matrix polarimeter for the determination of cervical cancer risk in the low resource setting

    NASA Astrophysics Data System (ADS)

    Ramella-Roman, Jessica C.; Gonzalez, Mariacarla; Chue-Sang, Joseph; Montejo, Karla; Krup, Karl; Srinivas, Vijaya; DeHoog, Edward; Madhivanan, Purnima

    2018-04-01

    Mueller Matrix polarimetry can provide useful information about the function and structure of the extracellular matrix. Mueller Matrix systems are sophisticated and costly optical tools that have been used primarily in the laboratory or in hospital settings. Here we introduce a low-cost snapshot Mueller Matrix polarimeter that that does not require external power, has no moving parts, and can acquire a full Mueller Matrix in less than 50 milliseconds. We utilized this technology in the study of cervical cancer in Mysore India, yet the system could be translated in multiple diagnostic applications.

  10. POLOCAM: a millimeter wavelength cryogenic polarimeter prototype for MUSIC-POL

    NASA Astrophysics Data System (ADS)

    Laurent, Glenn T.; Vaillancourt, John E.; Savini, Giorgio; Ade, Peter A. R.; Beland, Stephane; Glenn, Jason; Hollister, Matthew I.; Maloney, Philip R.; Sayers, Jack

    2012-09-01

    As a proof-of-concept, we have constructed and tested a cryogenic polarimeter in the laboratory as a prototype for the MUSIC instrument (Multiwavelength Sub/millimeter Kinetic Inductance Camera). The POLOCAM instrument consists of a rotating cryogenic polarization modulator (sapphire half-waveplate) and polarization analyzer (lithographed copper polarizers deposited on a thin film) placed into the optical path at the Lyot stop (4K cold pupil stop) in a cryogenic dewar. We present an overview of the project, design and performance results of the POLOCAM instrument (including polarization efficiencies and instrumental polarization), as well as future application to the MUSIC-POL instrument.

  11. Parallel, Real-Time and Pipeline Data Reduction for the ROVER Sub-mm Heterodyne Polarimeter on the JCMT with ACSIS and ORAC-DR

    NASA Astrophysics Data System (ADS)

    Leech, J.; Dewitt, S.; Jenness, T.; Greaves, J.; Lightfoot, J. F.

    2005-12-01

    ROVER is a rotating waveplate polarimeter for use with (sub)mm heterodyne instruments, particularly the 16 element focal plane Heterodyne Array Receiver HARP tep{Smit2003} due for commissioning on the JCMT in 2004. The ROVER/HARP back-end will be a digital auto-correlation spectrometer, known as ACSIS, designed specifically for the demanding data volumes from the HARP array receiver. ACSIS is being developed by DRAO, Penticton and UKATC. This paper will describe the data reduction of ROVER polarimetry data both in real-time by ACSIS-DR, and through the ORAC-DR data reduction pipeline.

  12. ASTROPOP: ASTROnomical Polarimetry and Photometry pipeline

    NASA Astrophysics Data System (ADS)

    Campagnolo, Julio C. N.

    2018-05-01

    AstroPoP reduces almost any CCD photometry and image polarimetry data. For photometry reduction, the code performs source finding, aperture and PSF photometry, astrometry calibration using different automated and non-automated methods and automated source identification and magnitude calibration based on online and local catalogs. For polarimetry, the code resolves linear and circular Stokes parameters produced by image beam splitter or polarizer polarimeters. In addition to the modular functions, ready-to-use pipelines based in configuration files and header keys are also provided with the code. AstroPOP was initially developed to reduce the IAGPOL polarimeter data installed at Observatório Pico dos Dias (Brazil).

  13. Highly Uniform 150 mm Diameter Multichroic Polarimeter Array Deployed for CMB Detection

    NASA Technical Reports Server (NTRS)

    Ho, Shuay-Pwu Patty; Austermann, Jason; Beall, James A.; Choi, Steve K.; Cothard, Nicholas F.; Crowley, Kevin; Datta, Rahul; Devlin, Mark J.; Duff, Shannon M.; Wollack, Edward J.

    2016-01-01

    The Advanced Atacama Cosmology Telescope Polarimeter is an upgraded receiver for the Atacama Cosmology Telescope, which has begun making measurements of the small angular scale polarization anisotropies in the Cosmic Microwave Background using the first of four new multichroic superconducting detector arrays. Here, we review all details of the optimization and characterization of this first array, which features 2012 AlMn transition edge sensor bolometers operating at 150 and 230 GHz. We present critical temperatures, thermal conductivities,saturation powers, time constants, and sensitivities for the array. The results show high uniformity across the 150 mm wafer and good performance in the field.

  14. A double-arm Møller Polarimeter for Jefferson Lab's Hall B

    NASA Astrophysics Data System (ADS)

    Grún, E.; Krúger, H.; Dermott, S.; Fechtig, H.; Graps, A. L.; Zook, H. A.; Gustafson, B. A.; Hamilton, D. P.; Hanner, M. S.; Heck, A.; Horányi, M.; Kissel, J.; Lindbad, B. A.; Linkert, D.; Linkert, G.; Mann, I.; Mcdonnell, J. A. M.; Morfill, G. E.; Polanskey, C.; Schwehm, G.; Srama, R.

    1998-10-01

    We have constructed and commissioned a double-arm Møller polarimeter for the Hall B beamline at the Thomas Jefferson National Accelerator Facility. The polarimeter measures the longitudinal polarization of the 0.8-4.0 GeV electron beam as it enters the experimental hall. The primary components of the apparatus are a target chamber, a pair of quadrupole magnets, and a pair of lead/scintillating-fiber detectors. The target chamber contains two 20 μm-thick permendur foils tilted at ± 20^o with respect to the beam axis. A target polarization of approximately 8% is produced along the beam direction by a 90 G (nominal) magnetic field generated by a pair of Helmholtz coils. The scattered Møller-electron pairs are directed toward the detectors by the quadrupoles. The quadrupoles are are individually tuned--depending on the beam energy--to center the peak of the Møller asymmetry (θ_c.m.=90^o) onto the fixed detectors. The real-to-accidental coincident-detection rate is better than 200:1. The beam polarization can be measured to a 3% relative statistical precision in less than 30 minutes with a relative systematic uncertainty of less than 5%.

  15. Neutron Detection Efficiency Optimization Studies of the Neutron Polarimeter for the C-GEN Electric Form Factor at Jefferson National Laboratory

    NASA Astrophysics Data System (ADS)

    Adzima, Ashley; Tireman, William; C-Gen Collaboration

    The electric form factor is an important quantity to further the understanding of the atom and its constituent parts. The C-GEN collaboration at Jefferson National Laboratory plans to measure this fundamental quantity using recoil polarimetry. An efficient neutron polarimeter is essential for the collection of precise data and involves maximizing the ratio of elastic to inelastic events identified. The determination of the elastic to inelastic ratio of neutron events was simulated using GEANT-4 on 5 cm, 10 cm, and 15 cm thick detectors. Specific requirements were set in place by C-GEN to determine what marks an elastic event. Plots of neutron scattering events versus detector thickness were analyzed, and the ratio of elastic to inelastic events was extracted for each section per vertical slice, as well as an average ratio. The average ratio of elastic to inelastic events were 0.2206, 0.1706, and 0.1507 for the 5 cm, 10 cm, and 15 cm detectors, respectfully. The impact of these ratios on the statistics and costs of altering the polarimeter's original 10 cm detector design will be further discussed. U.S. Department of Education - TRIO McNair Scholars Program.

  16. The Galway astronomical Stokes polarimeter: an all-Stokes optical polarimeter with ultra-high time resolution

    NASA Astrophysics Data System (ADS)

    Collins, Patrick; Kyne, Gillian; Lara, David; Redfern, Michael; Shearer, Andy; Sheehan, Brendan

    2013-12-01

    Many astronomical objects emit polarised light, which can give information both about their source mechanisms, and about (scattering) geometry in their source regions. To date (mostly) only the linearly polarised components of the emission have been observed in stellar sources. Observations have been constrained because of instrumental considerations to periods of excellent observing conditions, and to steady, slowly or periodically-varying sources. This leaves a whole range of interesting objects beyond the range of observation at present. The Galway Astronomical Stokes Polarimeter (GASP) has been developed to enable us to make observations on these very sources. GASP measures the four components of the Stokes Vector simultaneously over a broad wavelength range 400-800 nm., with a time resolution of order microseconds given suitable detectors and a bright source - this is possible because the optical design contains no moving or modulating components. The initial design of GASP is presented and we include some preliminary observational results demonstrating that components of the Stokes vector can be measured to % in conditions of poor atmospheric stability. Issues of efficiency and stability are addressed. An analysis of suitable astronomical targets, demanding the unique properties of GASP, is also presented.

  17. Development and manufacturing of panoramic Stokes polarimeter using the polarization films in the Main Astronomical Observatory of NAS of Ukraine

    NASA Astrophysics Data System (ADS)

    Vidmachenko, A. P.; Ivanov, Yu. S.; Syniavskyi, I. I.; Sergeev, A. V.

    2015-08-01

    In the Main Astronomical Observatory of NAS of Ukraine is proposed and implemented the concept of the imaging Stokes polarimeter [1-5]. This device allows carrying out measurements of the four Stokes vector components at the same time, in a wide field, and without any restrictions on the relative aperture of the optical system. Its scheme is developed so that only by turning wheel with replaceable elements, photopolarimeter could be transformed into a low resolution spectropolarimeter. The device has four film's polarizers with positional angles 0°, 45°, 90°, 135°. The device uses a system of special deflecting prisms in each channel. These prisms were achromatizing in the spectral range of 420-850 nm [2], the distortion of the polarimeter optical system is less than 0.65%. In manufacturing version of spectropolarimeter provided for the possibility of using working on passing the diffraction grating with a frequency up to 100 lines/mm. Has begun the laboratory testing of instrument. References. 1. Sinyavskii I.I., Ivanov Yu. S., Vidmachenko Anatoliy P., Karpov N.V. Panoramic Stokes-polarimeter // Ecological bulettin of research centers of the Black Sea Economic Cooperation. - 2013. - V. 3, No 4. - P. 123-127. 2. Sinyavskii I. I., Ivanov Yu. S., Vil'machenko A. P. Concept of the construction, of the optical setup of a panoramic Stokes polarimeter for small telescopes // Journal of Optical Technology. - 2013. - V. 80, Issue 9. - P. 545-548. 3. Vidmachenko A. P., Ivanov Yu. S., Morozhenko A. V., Nevodovsky E. P., Syniavskyi I. I., Sosonkin M. G. Spectropolarimeter of ground-based accompanying for the space experiment "Planetary Monitoring" // Kosmichna Nauka i Tekhnologiya. - 2007. - V. 13, No. 1, p. 63 - 70. 4. Yatskiv Ya. S., Vidmachenko A. P., Morozhenko A. V., Sosonkin M. G., Ivanov Yu. S., Syniavskyi I. I. Spectropolarimetric device for overatmospheric investigations of Solar System bodies // Kosmichna Nauka i Tekhnologiya. - 2008. - V. 14, No. 2. - P. 56-67. 5. Yatskiv Ya. S., Vidmachenk o A. P., Morozhenko A. V., Sosonkin M. G., Ivanov Yu. S., Sinyavskiy I. I. Spectropolarimetric devices for extraterrestrial investigation of the Solar system bodies // 10 Ukrainian Conference on Space Research with International Participation. August 30-September 4, 2010. The program and abstracts. Yevpatoria, Ukraine. P. 81.

  18. Large-scale horizontal flows from SOUP observations of solar granulation

    NASA Astrophysics Data System (ADS)

    November, L. J.; Simon, G. W.; Tarbell, T. D.; Title, A. M.; Ferguson, S. H.

    1987-09-01

    Using high-resolution time-sequence photographs of solar granulation from the SOUP experiment on Spacelab 2 the authors observed large-scale horizontal flows in the solar surface. The measurement method is based upon a local spatial cross correlation analysis. The horizontal motions have amplitudes in the range 300 to 1000 m/s. Radial outflow of granulation from a sunspot penumbra into the surrounding photosphere is a striking new discovery. Both the supergranulation pattern and cellular structures having the scale of mesogranulation are seen. The vertical flows that are inferred by continuity of mass from these observed horizontal flows have larger upflow amplitudes in cell centers than downflow amplitudes at cell boundaries.

  19. Decoding the Assessment Alphabet Soup

    NASA Astrophysics Data System (ADS)

    Engelhardt, Paula

    2010-10-01

    The number of assessment instruments that help physics instructors evaluate the conceptual learning of their students has grown over the last twenty years. Today, the number of tests that are available begin to look like an alphabet soup, FCI, MBT, TUG-K, CSE, CSM, CSEM, DIRECT, BEMA, LOCE, FMCE, SEMCO, etc. What can these assessment tests do for you that is different from what you regularly do? How do these tests differ from the tests and other assessments you already give in class? What is meant by formative and summative assessment and why should you care? What are some of the issues associated with giving one of these assessment tests? These are the questions that will be addressed in this talk.

  20. Universal statistics of vortex tangles in three-dimensional random waves

    NASA Astrophysics Data System (ADS)

    Taylor, Alexander J.

    2018-02-01

    The tangled nodal lines (wave vortices) in random, three-dimensional wavefields are studied as an exemplar of a fractal loop soup. Their statistics are a three-dimensional counterpart to the characteristic random behaviour of nodal domains in quantum chaos, but in three dimensions the filaments can wind around one another to give distinctly different large scale behaviours. By tracing numerically the structure of the vortices, their conformations are shown to follow recent analytical predictions for random vortex tangles with periodic boundaries, where the local disorder of the model ‘averages out’ to produce large scale power law scaling relations whose universality classes do not depend on the local physics. These results explain previous numerical measurements in terms of an explicit effect of the periodic boundaries, where the statistics of the vortices are strongly affected by the large scale connectedness of the system even at arbitrarily high energies. The statistics are investigated primarily for static (monochromatic) wavefields, but the analytical results are further shown to directly describe the reconnection statistics of vortices evolving in certain dynamic systems, or occurring during random perturbations of the static configuration.

Top