Sample records for unrecognized preanalytical problem

  1. Practical solution for control of the pre-analytical phase in decentralized clinical laboratories for meeting the requirements of the medical laboratory accreditation standard DIN EN ISO 15189.

    PubMed

    Vacata, Vladimir; Jahns-Streubel, Gerlinde; Baldus, Mirjana; Wood, William Graham

    2007-01-01

    This report was written in response to the article by Wood published recently in this journal. It describes a practical solution to the problems of controlling the pre-analytical phase in the clinical diagnostic laboratory. As an indicator of quality in the pre-analytical phase of sample processing, a target analyte was chosen which is sensitive to delay in centrifugation and/or analysis. The results of analyses of the samples sent by satellite medical practitioners were compared with those from an on-site hospital laboratory with a controllable optimized pre-analytical phase. The aim of the comparison was: (a) to identify those medical practices whose mean/median sample values significantly deviate from those of the control situation in the hospital laboratory due to the possible problems in the pre-analytical phase; (b) to aid these laboratories in the process of rectifying these problems. A Microsoft Excel-based Pre-Analytical Survey tool (PAS tool) has been developed which addresses the above mentioned problems. It has been tested on serum potassium which is known to be sensitive to delay and/or irregularities in sample treatment. The PAS tool has been shown to be one possibility for improving the quality of the analyses by identifying the sources of problems within the pre-analytical phase, thus allowing them to be rectified. Additionally, the PAS tool has an educational value and can also be adopted for use in other decentralized laboratories.

  2. 42 CFR 493.1240 - Condition: Preanalytic systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Preanalytic systems. 493.1240 Section 493.1240 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... of the preanalytic systems and correct identified problems as specified in § 493.1249 for each...

  3. Preanalytical requirements of urinalysis

    PubMed Central

    Delanghe, Joris; Speeckaert, Marijn

    2014-01-01

    Urine may be a waste product, but it contains an enormous amount of information. Well-standardized procedures for collection, transport, sample preparation and analysis should become the basis of an effective diagnostic strategy for urinalysis. As reproducibility of urinalysis has been greatly improved due to recent technological progress, preanalytical requirements of urinalysis have gained importance and have become stricter. Since the patients themselves often sample urine specimens, urinalysis is very susceptible to preanalytical issues. Various sampling methods and inappropriate specimen transport can cause important preanalytical errors. The use of preservatives may be helpful for particular analytes. Unfortunately, a universal preservative that allows a complete urinalysis does not (yet) exist. The preanalytical aspects are also of major importance for newer applications (e.g. metabolomics). The present review deals with the current preanalytical problems and requirements for the most common urinary analytes. PMID:24627718

  4. Preanalytics in lung cancer.

    PubMed

    Warth, Arne; Muley, Thomas; Meister, Michael; Weichert, Wilko

    2015-01-01

    Preanalytic sampling techniques and preparation of tissue specimens strongly influence analytical results in lung tissue diagnostics both on the morphological but also on the molecular level. However, in contrast to analytics where tremendous achievements in the last decade have led to a whole new portfolio of test methods, developments in preanalytics have been minimal. This is specifically unfortunate in lung cancer, where usually only small amounts of tissue are at hand and optimization in all processing steps is mandatory in order to increase the diagnostic yield. In the following, we provide a comprehensive overview on some aspects of preanalytics in lung cancer from the method of sampling over tissue processing to its impact on analytical test results. We specifically discuss the role of preanalytics in novel technologies like next-generation sequencing and in the state-of the-art cytology preparations. In addition, we point out specific problems in preanalytics which hamper further developments in the field of lung tissue diagnostics.

  5. Current projects in Pre-analytics: where to go?

    PubMed

    Sapino, Anna; Annaratone, Laura; Marchiò, Caterina

    2015-01-01

    The current clinical practice of tissue handling and sample preparation is multifaceted and lacks strict standardisation: this scenario leads to significant variability in the quality of clinical samples. Poor tissue preservation has a detrimental effect thus leading to morphological artefacts, hampering the reproducibility of immunocytochemical and molecular diagnostic results (protein expression, DNA gene mutations, RNA gene expression) and affecting the research outcomes with irreproducible gene expression and post-transcriptional data. Altogether, this limits the opportunity to share and pool national databases into European common databases. At the European level, standardization of pre-analytical steps is just at the beginning and issues regarding bio-specimen collection and management are still debated. A joint (public-private) project entitled on standardization of tissue handling in pre-analytical procedures has been recently funded in Italy with the aim of proposing novel approaches to the neglected issue of pre-analytical procedures. In this chapter, we will show how investing in pre-analytics may impact both public health problems and practical innovation in solid tumour processing.

  6. Blood venous sample collection: Recommendations overview and a checklist to improve quality.

    PubMed

    Giavarina, Davide; Lippi, Giuseppe

    2017-07-01

    The extra-analytical phases of the total testing process have substantial impact on managed care, as well as an inherent high risk of vulnerability to errors which is often greater than that of the analytical phase. The collection of biological samples is a crucial preanalytical activity. Problems or errors occurring shortly before, or soon after, this preanalytical step may impair sample quality and characteristics, or else modify the final results of testing. The standardization of fasting requirements, rest, patient position and psychological state of the patient are therefore crucial for mitigating the impact of preanalytical variability. Moreover, the quality of materials used for collecting specimens, along with their compatibility, can guarantee sample quality and persistence of chemical and physical characteristics of the analytes over time, so safeguarding the reliability of testing. Appropriate techniques and sampling procedures are effective to prevent problems such as hemolysis, undue clotting in the blood tube, draw of insufficient sample volume and modification of analyte concentration. An accurate identification of both patient and blood samples is a key priority as for other healthcare activities. Good laboratory practice and appropriate training of operators, by specifically targeting collection of biological samples, blood in particular, may greatly improve this issue, thus lowering the risk of errors and their adverse clinical consequences. The implementation of a simple and rapid check-list, including verification of blood collection devices, patient preparation and sampling techniques, was found to be effective for enhancing sample quality and reducing some preanalytical errors associated with these procedures. The use of this tool, along with implementation of objective and standardized systems for detecting non-conformities related to unsuitable samples, can be helpful for standardizing preanalytical activities and improving the quality of laboratory diagnostics, ultimately helping to reaffirm a "preanalytical" culture founded on knowledge and real risk perception. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  7. Pre-analytical issues in the haemostasis laboratory: guidance for the clinical laboratories.

    PubMed

    Magnette, A; Chatelain, M; Chatelain, B; Ten Cate, H; Mullier, F

    2016-01-01

    Ensuring quality has become a daily requirement in laboratories. In haemostasis, even more than in other disciplines of biology, quality is determined by a pre-analytical step that encompasses all procedures, starting with the formulation of the medical question, and includes patient preparation, sample collection, handling, transportation, processing, and storage until time of analysis. This step, based on a variety of manual activities, is the most vulnerable part of the total testing process and is a major component of the reliability and validity of results in haemostasis and constitutes the most important source of erroneous or un-interpretable results. Pre-analytical errors may occur throughout the testing process and arise from unsuitable, inappropriate or wrongly handled procedures. Problems may arise during the collection of blood specimens such as misidentification of the sample, use of inadequate devices or needles, incorrect order of draw, prolonged tourniquet placing, unsuccessful attempts to locate the vein, incorrect use of additive tubes, collection of unsuitable samples for quality or quantity, inappropriate mixing of a sample, etc. Some factors can alter the result of a sample constituent after collection during transportation, preparation and storage. Laboratory errors can often have serious adverse consequences. Lack of standardized procedures for sample collection accounts for most of the errors encountered within the total testing process. They can also have clinical consequences as well as a significant impact on patient care, especially those related to specialized tests as these are often considered as "diagnostic". Controlling pre-analytical variables is critical since this has a direct influence on the quality of results and on their clinical reliability. The accurate standardization of the pre-analytical phase is of pivotal importance for achieving reliable results of coagulation tests and should reduce the side effects of the influence factors. This review is a summary of the most important recommendations regarding the importance of pre-analytical factors for coagulation testing and should be a tool to increase awareness about the importance of pre-analytical factors for coagulation testing.

  8. 42 CFR 493.1249 - Standard: Preanalytic systems quality assessment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Preanalytic systems quality assessment... Nonwaived Testing Preanalytic Systems § 493.1249 Standard: Preanalytic systems quality assessment. (a) The....1241 through 493.1242. (b) The preanalytic systems quality assessment must include a review of the...

  9. Strategies for improving the collection of 24-hour urine for analysis in the clinical laboratory: redesigned instructions, opinion surveys, and application of reference change value to micturition.

    PubMed

    Tormo, Consuelo; Lumbreras, Blanca; Santos, Ana; Romero, Luis; Conca, Minerva

    2009-12-01

    -The preanalytic phase of 24-hour urine collection, before clinical analysis, requires the active participation of patients and usually takes place outside the laboratory. -We verify whether distribution of adequate information to health care personnel and patients will result in fewer preanalytic incidents. We also determine the intraindividual biologic variability associated with micturition and the corresponding reference change value (RCV). -The intervention provided training for 24-hour urine collection to the health care personnel of the 20th health district of the Valencian community in Spain. The preanalytic incidents related to 24-hour micturition were estimated before and after the intervention. An opinion survey on the problems involved in urine collection was also conducted among patients. The Harris formula was used to calculate the RCV. -Before the intervention, 130 preanalytic incidents were recorded (11.5%) and after the intervention, 76 (8.6%) (P = .04) were recorded. Of the 130 incidents recorded before the intervention, 63 (48.5%) involved omission to indicate the urine volume, and of the 76 incidents recorded after the intervention, only 1 (1.3%) (P < .001) involved this omission. Forty of 302 patients (13.2%) surveyed reported problems and more than half (175; 57.9%) had to collect various urine samples sequentially. The RCV determined was 54.5% for a percentage of variation in volume of 24-hour urine (PVVI) of 19.0 +/- 16.5%. Therefore, micturition associated with a PVVI >+/-54.5% suggests that 24-hour urine collection by the patient was incomplete. The results obtained when applying the RCV after the intervention showed that 6.3% of the 24-hour urine samples should be rejected. -The percentage of preanalytic incidents was reduced by providing health care personnel with information and training. The percentage of variation in volume of 24-hour urine can be used to evaluate the variation in patients' micturition. Reference change value was shown to be useful when determining whether 24-hour urine was properly collected.

  10. Monitoring and reporting of preanalytical errors in laboratory medicine: the UK situation.

    PubMed

    Cornes, Michael P; Atherton, Jennifer; Pourmahram, Ghazaleh; Borthwick, Hazel; Kyle, Betty; West, Jamie; Costelloe, Seán J

    2016-03-01

    Most errors in the clinical laboratory occur in the preanalytical phase. This study aimed to comprehensively describe the prevalence and nature of preanalytical quality monitoring practices in UK clinical laboratories. A survey was sent on behalf of the Association for Clinical Biochemistry and Laboratory Medicine Preanalytical Working Group (ACB-WG-PA) to all heads of department of clinical laboratories in the UK. The survey captured data on the analytical platform and Laboratory Information Management System in use; which preanalytical errors were recorded and how they were classified and gauged interest in an external quality assurance scheme for preanalytical errors. Of the 157 laboratories asked to participate, responses were received from 104 (66.2%). Laboratory error rates were recorded per number of specimens, rather than per number of requests in 51% of respondents. Aside from serum indices for haemolysis, icterus and lipaemia, which were measured in 80% of laboratories, the most common errors recorded were booking-in errors (70.1%) and sample mislabelling (56.9%) in laboratories who record preanalytical errors. Of the laboratories surveyed, 95.9% expressed an interest in guidance on recording preanalytical error and 91.8% expressed interest in an external quality assurance scheme. This survey observes a wide variation in the definition, repertoire and collection methods for preanalytical errors in the UK. Data indicate there is a lot of interest in improving preanalytical data collection. The ACB-WG-PA aims to produce guidance and support for laboratories to standardize preanalytical data collection and to help establish and validate an external quality assurance scheme for interlaboratory comparison. © The Author(s) 2015.

  11. Improving preanalytic processes using the principles of lean production (Toyota Production System).

    PubMed

    Persoon, Thomas J; Zaleski, Sue; Frerichs, Janice

    2006-01-01

    The basic technologies used in preanalytic processes for chemistry tests have been mature for a long time, and improvements in preanalytic processes have lagged behind improvements in analytic and postanalytic processes. We describe our successful efforts to improve chemistry test turnaround time from a central laboratory by improving preanalytic processes, using existing resources and the principles of lean production. Our goal is to report 80% of chemistry tests in less than 1 hour and to no longer recognize a distinction between expedited and routine testing. We used principles of lean production (the Toyota Production System) to redesign preanalytic processes. The redesigned preanalytic process has fewer steps and uses 1-piece flow to move blood samples through the accessioning, centrifugation, and aliquoting processes. Median preanalytic processing time was reduced from 29 to 19 minutes, and the laboratory met the goal of reporting 80% of chemistry results in less than 1 hour for 11 consecutive months.

  12. Ten years of preanalytical monitoring and control: Synthetic Balanced Score Card Indicator

    PubMed Central

    López-Garrigós, Maite; Flores, Emilio; Santo-Quiles, Ana; Gutierrez, Mercedes; Lugo, Javier; Lillo, Rosa; Leiva-Salinas, Carlos

    2015-01-01

    Introduction Preanalytical control and monitoring continue to be an important issue for clinical laboratory professionals. The aim of the study was to evaluate a monitoring system of preanalytical errors regarding not suitable samples for analysis, based on different indicators; to compare such indicators in different phlebotomy centres; and finally to evaluate a single synthetic preanalytical indicator that may be included in the balanced scorecard management system (BSC). Materials and methods We collected individual and global preanalytical errors in haematology, coagulation, chemistry, and urine samples analysis. We also analyzed a synthetic indicator that represents the sum of all types of preanalytical errors, expressed in a sigma level. We studied the evolution of those indicators over time and compared indicator results by way of the comparison of proportions and Chi-square. Results There was a decrease in the number of errors along the years (P < 0.001). This pattern was confirmed in primary care patients, inpatients and outpatients. In blood samples, fewer errors occurred in outpatients, followed by inpatients. Conclusion We present a practical and effective methodology to monitor unsuitable sample preanalytical errors. The synthetic indicator results summarize overall preanalytical sample errors, and can be used as part of BSC management system. PMID:25672466

  13. Quality Measures in Pre-Analytical Phase of Tissue Processing: Understanding Its Value in Histopathology.

    PubMed

    Rao, Shalinee; Masilamani, Suresh; Sundaram, Sandhya; Duvuru, Prathiba; Swaminathan, Rajendiran

    2016-01-01

    Quality monitoring in histopathology unit is categorized into three phases, pre-analytical, analytical and post-analytical, to cover various steps in the entire test cycle. Review of literature on quality evaluation studies pertaining to histopathology revealed that earlier reports were mainly focused on analytical aspects with limited studies on assessment of pre-analytical phase. Pre-analytical phase encompasses several processing steps and handling of specimen/sample by multiple individuals, thus allowing enough scope for errors. Due to its critical nature and limited studies in the past to assess quality in pre-analytical phase, it deserves more attention. This study was undertaken to analyse and assess the quality parameters in pre-analytical phase in a histopathology laboratory. This was a retrospective study done on pre-analytical parameters in histopathology laboratory of a tertiary care centre on 18,626 tissue specimens received in 34 months. Registers and records were checked for efficiency and errors for pre-analytical quality variables: specimen identification, specimen in appropriate fixatives, lost specimens, daily internal quality control performance on staining, performance in inter-laboratory quality assessment program {External quality assurance program (EQAS)} and evaluation of internal non-conformities (NC) for other errors. The study revealed incorrect specimen labelling in 0.04%, 0.01% and 0.01% in 2007, 2008 and 2009 respectively. About 0.04%, 0.07% and 0.18% specimens were not sent in fixatives in 2007, 2008 and 2009 respectively. There was no incidence of specimen lost. A total of 113 non-conformities were identified out of which 92.9% belonged to the pre-analytical phase. The predominant NC (any deviation from normal standard which may generate an error and result in compromising with quality standards) identified was wrong labelling of slides. Performance in EQAS for pre-analytical phase was satisfactory in 6 of 9 cycles. A low incidence of errors in pre-analytical phase implies that a satisfactory level of quality standards was being practiced with still scope for improvement.

  14. How to conduct External Quality Assessment Schemes for the pre-analytical phase?

    PubMed

    Kristensen, Gunn B B; Aakre, Kristin Moberg; Kristoffersen, Ann Helen; Sandberg, Sverre

    2014-01-01

    In laboratory medicine, several studies have described the most frequent errors in the different phases of the total testing process, and a large proportion of these errors occur in the pre-analytical phase. Schemes for registration of errors and subsequent feedback to the participants have been conducted for decades concerning the analytical phase by External Quality Assessment (EQA) organizations operating in most countries. The aim of the paper is to present an overview of different types of EQA schemes for the pre-analytical phase, and give examples of some existing schemes. So far, very few EQA organizations have focused on the pre-analytical phase, and most EQA organizations do not offer pre-analytical EQA schemes (EQAS). It is more difficult to perform and standardize pre-analytical EQAS and also, accreditation bodies do not ask the laboratories for results from such schemes. However, some ongoing EQA programs for the pre-analytical phase do exist, and some examples are given in this paper. The methods used can be divided into three different types; collecting information about pre-analytical laboratory procedures, circulating real samples to collect information about interferences that might affect the measurement procedure, or register actual laboratory errors and relate these to quality indicators. These three types have different focus and different challenges regarding implementation, and a combination of the three is probably necessary to be able to detect and monitor the wide range of errors occurring in the pre-analytical phase.

  15. Prevalence and types of preanalytical error in hematology laboratory of a tertiary care hospital in South India.

    PubMed

    Arul, Pitchaikaran; Pushparaj, Magesh; Pandian, Kanmani; Chennimalai, Lingasamy; Rajendran, Karthika; Selvaraj, Eniya; Masilamani, Suresh

    2018-01-01

    An important component of laboratory medicine is preanalytical phase. Since laboratory report plays a major role in patient management, more importance should be given to the quality of laboratory tests. The present study was undertaken to find the prevalence and types of preanalytical errors at a tertiary care hospital in South India. In this cross-sectional study, a total of 118,732 samples ([62,474 outpatient department [OPD] and 56,258 inpatient department [IPD]) were received in hematology laboratory. These samples were analyzed for preanalytical errors such as misidentification, incorrect vials, inadequate samples, clotted samples, diluted samples, and hemolyzed samples. The overall prevalence of preanalytical errors found was 513 samples, which is 0.43% of the total number of samples received. The most common preanalytical error observed was inadequate samples followed by clotted samples. Overall frequencies (both OPD and IPD) of preanalytical errors such as misidentification, incorrect vials, inadequate samples, clotted samples, diluted samples, and hemolyzed samples were 0.02%, 0.05%, 0.2%, 0.12%, 0.02%, and 0.03%, respectively. The present study concluded that incorrect phlebotomy techniques due to lack of awareness is the main reason for preanalytical errors. This can be avoided by proper communication and coordination between laboratory and wards, proper training and continuing medical education programs for laboratory and paramedical staffs, and knowledge of the intervening factors that can influence laboratory results.

  16. A Call to Standardize Preanalytic Data Elements for Biospecimens, Part II.

    PubMed

    Robb, James A; Bry, Lynn; Sluss, Patrick M; Wagar, Elizabeth A; Kennedy, Mary F

    2015-09-01

    Biospecimens must have appropriate clinical annotation (data) to ensure optimal quality for both patient care and research. Additional clinical preanalytic variables are the focus of this continuing study. To complete the identification of the essential preanalytic variables (data fields) that can, and in some instances should, be attached to every collected biospecimen by adding the additional specific variables for clinical chemistry and microbiology to our original 170 variables. The College of American Pathologists Diagnostic Intelligence and Health Information Technology Committee sponsored a second Biorepository Working Group to complete the list of preanalytic variables for annotating biospecimens. Members of the second Biorepository Working Group are experts in clinical pathology and microbiology. Additional preanalytic area-specific variables were identified and ranked along with definitions and potential negative impacts if the variable is not attached to the biospecimen. The draft manuscript was reviewed by additional national and international stakeholders. Four additional required preanalytic variables were identified specifically for clinical chemistry and microbiology biospecimens that can be used as a guide for site-specific implementation into patient care and research biorepository processes. In our collective experience, selecting which of the many preanalytic variables to attach to any specific set of biospecimens used for patient care and/or research is often difficult. The additional ranked list should be of practical benefit when selecting preanalytic variables for a given biospecimen collection.

  17. Privacy and equality in diagnostic genetic testing.

    PubMed

    Nyrhinen, Tarja; Hietala, Marja; Puukka, Pauli; Leino-Kilpi, Helena

    2007-05-01

    This study aimed to determine the extent to which the principles of privacy and equality were observed during diagnostic genetic testing according to views held by patients or child patients' parents (n = 106) and by staff (n = 162) from three Finnish university hospitals. The data were collected through a structured questionnaire and analysed using the SAS 8.1 statistical software. In general, the two principles were observed relatively satisfactorily in clinical practice. According to patients/parents, equality in the post-analytic phase and, according to staff, privacy in the pre-analytic phase, involved the greatest ethical problems. The two groups differed in their views concerning pre-analytic privacy. Although there were no major problems regarding the two principles, the differences between the testing phases require further clarification. To enhance privacy protection and equality, professionals need to be given more genetics/ethics training, and patients individual counselling by genetics units staff, giving more consideration to patients' world-view, the purpose of the test and the test result.

  18. Development and validation of dried matrix spot sampling for the quantitative determination of amyloid β peptides in cerebrospinal fluid.

    PubMed

    Delaby, Constance; Gabelle, Audrey; Meynier, Philippe; Loubiere, Vincent; Vialaret, Jérôme; Tiers, Laurent; Ducos, Jacques; Hirtz, Christophe; Lehmann, Sylvain

    2014-05-01

    The use of dried blood spots on filter paper is well documented as an affordable and practical alternative to classical venous sampling for various clinical needs. This technique has indeed many advantages in terms of collection, biological safety, storage, and shipment. Amyloid β (Aβ) peptides are useful cerebrospinal fluid (CSF) biomarkers for Alzheimer disease diagnosis. However, Aβ determination is hindered by preanalytical difficulties in terms of sample collection and stability in tubes. We compared the quantification of Aβ peptides (1-40, 1-42, and 1-38) by simplex and multiplex ELISA, following either a standard operator method (liquid direct quantification) or after spotting CSF onto dried matrix paper card. The use of dried matrix spot (DMS) overcame preanalytical problems and allowed the determination of Aβ concentrations that were highly commutable (Bland-Altman) with those obtained using CSF in classical tubes. Moreover, we found a positive and significant correlation (r2=0.83, Pearson coefficient p=0.0329) between the two approaches. This new DMS method for CSF represents an interesting alternative that increases the quality and efficiency in preanalytics. This should enable the better exploitation of Aβ analytes for Alzheimer's diagnosis.

  19. National survey on the pre-analytical variability in a representative cohort of Italian laboratories.

    PubMed

    Lippi, Giuseppe; Montagnana, Martina; Giavarina, Davide

    2006-01-01

    Owing to remarkable advances in automation, laboratory technology and informatics, the pre-analytical phase has become the major source of variability in laboratory testing. The present survey investigated the development of several pre-analytical processes within a representative cohort of Italian clinical laboratories. A seven-point questionnaire was designed to investigate the following issues: 1a) the mean outpatient waiting time before check-in and 1b) the mean time from check-in to sample collection; 2) the mean time from sample collection to analysis; 3) the type of specimen collected for clinical chemistry testing; 4) the degree of pre-analytical automation; 5a) the number of samples shipped to other laboratories and 5b) the availability of standardised protocols for transportation; 6) the conditions for specimen storage; and 7) the availability and type of guidelines for management of unsuitable specimens. The questionnaire was administered to 150 laboratory specialists attending the SIMEL (Italian Society of Laboratory Medicine) National Meeting in June 2006. 107 questionnaires (71.3%) were returned. Data analysis revealed a high degree of variability among laboratories for the time required for check-in, outpatient sampling, sample transportation to the referral laboratory and analysis upon the arrival. Only 31% of laboratories have automated some pre-analytical steps. Of the 87% of laboratories that ship specimens to other facilities without sample preparation, 19% have no standardised protocol for transportation. For conventional clinical chemistry testing, 74% of the laboratories use serum evacuated tubes (59% with and 15% without serum separator), whereas the remaining 26% use lithium-heparin evacuated tubes (11% with and 15% without plasma separator). The storage period and conditions for rerun/retest vary widely. Only 63% of laboratories have a codified procedure for the management of unsuitable specimens, which are recognised by visual inspection (69%) or automatic detection (29%). Only 56% of the laboratories have standardised procedures for the management of unsuitable specimens, which vary widely on a local basis. The survey highlights broad heterogeneity in several pre-analytical processes among Italian laboratories. The lack of reliable guidelines encompassing evidence-based practice is a major problem for the standardisation of this crucial part of the testing process and represents a major challenge for laboratory medicine in the 2000s.

  20. A call to standardize preanalytic data elements for biospecimens.

    PubMed

    Robb, James A; Gulley, Margaret L; Fitzgibbons, Patrick L; Kennedy, Mary F; Cosentino, L Mark; Washington, Kay; Dash, Rajesh C; Branton, Philip A; Jewell, Scott D; Lapham, Rosanna L

    2014-04-01

    Biospecimens must have appropriate clinical annotation (data) to ensure optimal quality for both patient care and research. Clinical preanalytic variables are the focus of this study. To define the essential preanalytic variables (data fields) that should be attached to every collected biospecimen and to provide a complete list of such variables, along with their relative importance, which can vary, depending on downstream use, institutional needs, and information technology capabilities. The College of American Pathologists Diagnostic Intelligence and Health Information Technology Committee sponsored a Biorepository Working Group to develop a ranked list of the preanalytic variables for annotating biospecimens. Members of the working group were experts in anatomic, clinical, and molecular pathology; biobanking; medical informatics; and accreditation. Several members had experience with federal government programs, such as the National Cancer Institute's Biospecimens and Biorepository Branch and the National Cancer Institute's Community Cancer Center Program. Potential preanalytic variables were identified and ranked along with available supporting evidence, definitions, and potential negative effects if the variable was not attached to the biospecimen. Additional national and international stakeholders reviewed the draft manuscript. The ranked listing of 170 preanalytic variables produced can be used as a guide for site-specific implementation into patient care and/or research biorepository processes. Conclusions.-In our collective experience, it is often difficult to choose which of the many preanalytic variables to attach to any specific set of biospecimens used for patient care and/or research. The provided ranked list should aid in the selection of preanalytic variables for a given biospecimen collection.

  1. Improving quality in the preanalytical phase through innovation, on behalf of the European Federation for Clinical Chemistry and Laboratory Medicine (EFLM) Working Group for Preanalytical Phase (WG-PRE).

    PubMed

    Lippi, Giuseppe; Baird, Geoffrey S; Banfi, Giuseppe; Bölenius, Karin; Cadamuro, Janne; Church, Stephen; Cornes, Michael P; Dacey, Anna; Guillon, Antoine; Hoffmann, Georg; Nybo, Mads; Premawardhana, Lakdasa Devananda; Salinas, María; Sandberg, Sverre; Slingerland, Robbert; Stankovic, Ana; Sverresdotter, Sylte Marit; Vermeersch, Pieter; Simundic, Ana-Maria

    2017-03-01

    It is now undeniable that laboratory testing is vital for the diagnosis, prognostication and therapeutic monitoring of human disease. Despite the many advances made for achieving a high degree of quality and safety in the analytical part of diagnostic testing, many hurdles in the total testing process remain, especially in the preanalytical phase ranging from test ordering to obtaining and managing the biological specimens. The Working Group for the Preanalytical Phase (WG-PRE) of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) has planned many activities aimed at mitigating the vulnerability of the preanalytical phase, including the organization of three European meetings in the past 7 years. Hence, this collective article follows the previous three opinion papers that were published by the EFLM WGPRE on the same topic, and brings together the summaries of the presentations that will be given at the 4th EFLM-BD meeting "Improving quality in the preanalytical phase through innovation" in Amsterdam, 24-25 March, 2017.

  2. Chemistry and haematology sample rejection and clinical impact in a tertiary laboratory in Cape Town.

    PubMed

    Jacobsz, Lourens A; Zemlin, Annalise E; Roos, Mark J; Erasmus, Rajiv T

    2011-10-14

    Recent publications report that up to 70% of total laboratory errors occur in the pre-analytical phase. Identification of specific problems highlights pre-analytic processes susceptible to errors. The rejection of unsuitable samples can lead to delayed turnaround time and affect patient care. A retrospective audit was conducted investigating the rejection rate of routine blood specimens received at chemistry and haematology laboratories over a 2-week period. The reasons for rejection and potential clinical impact of these rejections were investigated. Thirty patient files were randomly selected and examined to assess the impact of these rejections on clinical care. A total of 32,910 specimens were received during the study period, of which 481 were rejected, giving a rejection rate of 1.46%. The main reasons for rejection were inappropriate clotting (30%) and inadequate sample volume (22%). Only 51.7% of rejected samples were repeated and the average time for a repeat sample to reach the laboratory was about 5 days (121 h). Of the repeated samples, 5.1% had results within critical values. Examination of patient folders showed that in 40% of cases the rejection of samples had an impact on patient care. The evaluation of pre-analytical processes in the laboratory, with regard to sample rejection, allowed one to identify problem areas where improvement is necessary. Rejected samples due to factors out of the laboratory's control had a definite impact on patient care and can thus affect customer satisfaction. Clinicians should be aware of these factors to prevent such rejections.

  3. Is a pre-analytical process for urinalysis required?

    PubMed

    Petit, Morgane; Beaudeux, Jean-Louis; Majoux, Sandrine; Hennequin, Carole

    2017-10-01

    For the reliable urinary measurement of calcium, phosphate and uric acid, a pre-analytical process by adding acid or base to urine samples at laboratory is recommended in order to dissolve precipitated solutes. Several studies on different kind of samples and analysers have previously shown that a such pre-analytical treatment is useless. The objective was to study the necessity of pre-analytical treatment of urine on samples collected using the V-Monovette ® (Sarstedt) system and measured on the analyser Architect C16000 (Abbott Diagnostics). Sixty urinary samples of hospitalized patients were selected (n=30 for calcium and phosphate, and n=30 for uric acid). After acidification of urine samples for measurement of calcium and phosphate, and alkalinisation for measurement of uric acid respectively, differences between results before and after the pre-analytical treatment were compared to acceptable limits recommended by the French society of clinical biology (SFBC). No difference in concentration between before and after pre-analytical treatment of urine samples exceeded acceptable limits from SFBC for measurement of calcium and uric acid. For phosphate, only one sample exceeded these acceptable limits, showing a result paradoxically lower after acidification. In conclusion, in agreement with previous study, our results show that acidification or alkalinisation of urine samples from 24 h urines or from urination is not a pre-analytical necessity for measurement of calcium, phosphate and uric acid.

  4. Preanalytical errors in medical laboratories: a review of the available methodologies of data collection and analysis.

    PubMed

    West, Jamie; Atherton, Jennifer; Costelloe, Seán J; Pourmahram, Ghazaleh; Stretton, Adam; Cornes, Michael

    2017-01-01

    Preanalytical errors have previously been shown to contribute a significant proportion of errors in laboratory processes and contribute to a number of patient safety risks. Accreditation against ISO 15189:2012 requires that laboratory Quality Management Systems consider the impact of preanalytical processes in areas such as the identification and control of non-conformances, continual improvement, internal audit and quality indicators. Previous studies have shown that there is a wide variation in the definition, repertoire and collection methods for preanalytical quality indicators. The International Federation of Clinical Chemistry Working Group on Laboratory Errors and Patient Safety has defined a number of quality indicators for the preanalytical stage, and the adoption of harmonized definitions will support interlaboratory comparisons and continual improvement. There are a variety of data collection methods, including audit, manual recording processes, incident reporting mechanisms and laboratory information systems. Quality management processes such as benchmarking, statistical process control, Pareto analysis and failure mode and effect analysis can be used to review data and should be incorporated into clinical governance mechanisms. In this paper, The Association for Clinical Biochemistry and Laboratory Medicine PreAnalytical Specialist Interest Group review the various data collection methods available. Our recommendation is the use of the laboratory information management systems as a recording mechanism for preanalytical errors as this provides the easiest and most standardized mechanism of data capture.

  5. Preanalytical external quality assessment of the Croatian Society of Medical Biochemistry and Laboratory Medicine and CROQALM: finding undetected weak spots.

    PubMed

    Nikolac, Nora; Krleza, Jasna Lenicek; Simundic, Ana-Maria

    2017-02-15

    The aim of this paper is to present results of first two years of preanalytical external quality assessment (EQA) in Croatia. This paper summarizes results from 6 rounds of preanalytical EQA during 2014-2016 in 161-175 Croatian laboratories (number ranged between cycles). EQA was designed as an online survey of the compliance with National recommendations for phlebotomy (NRP). Forty-seven questions in 5 categories are analyzed (materials and equipment, patient identification, patient preparation, sampling and storage). Additionally, preanalytical cases are presented. Overall performance scores (Question score (Qscore) for compliance with NRP and Case score (Cscore) for preanalytical cases) are calculated for each question/case as a proportion of laboratories with satisfactory procedure (x 100). Qscores and Cscores ≥ 70 were classified as acceptable (maximal score = 100). In investigation of compliance with NRP, acceptable Qscores were obtained for 34/47 questions. The lowest scores were observed for the availability of sterile disposable tourniquets (Qscore = 15) and safe-sharp needles (Qscore = 34), obtaining patients address as an identifier (Qscore = 21), using glycolysis inhibitor tubes for glucose concentration measurement (Qscore = 21) and verification of manufacturers declarations on temperature and time of storage (Qscore = 31). There was no statistically significant difference in overall Qscore according to different categories of phlebotomy procedures (P = 0.284). The results of preanalytical cases showed acceptable Cscore values for all cases (89-96). First two years of preanalytical EQA showed good compliance with the NRP and excellent expertise in resolving complex preanalytical issues. Major critical spots are lack of availability of safe-sharp needles, disposable tourniquets and glucose inhibitor tubes.

  6. Preanalytical external quality assessment of the Croatian Society of Medical Biochemistry and Laboratory Medicine and CROQALM: finding undetected weak spots

    PubMed Central

    Nikolac, Nora; Krleza, Jasna Lenicek; Simundic, Ana-Maria

    2017-01-01

    Introduction The aim of this paper is to present results of first two years of preanalytical external quality assessment (EQA) in Croatia. Materials and methods This paper summarizes results from 6 rounds of preanalytical EQA during 2014-2016 in 161-175 Croatian laboratories (number ranged between cycles). EQA was designed as an online survey of the compliance with National recommendations for phlebotomy (NRP). Forty-seven questions in 5 categories are analyzed (materials and equipment, patient identification, patient preparation, sampling and storage). Additionally, preanalytical cases are presented. Overall performance scores (Question score (Qscore) for compliance with NRP and Case score (Cscore) for preanalytical cases) are calculated for each question/case as a proportion of laboratories with satisfactory procedure (x 100). Qscores and Cscores ≥ 70 were classified as acceptable (maximal score = 100). Results In investigation of compliance with NRP, acceptable Qscores were obtained for 34/47 questions. The lowest scores were observed for the availability of sterile disposable tourniquets (Qscore = 15) and safe-sharp needles (Qscore = 34), obtaining patients address as an identifier (Qscore = 21), using glycolysis inhibitor tubes for glucose concentration measurement (Qscore = 21) and verification of manufacturers declarations on temperature and time of storage (Qscore = 31). There was no statistically significant difference in overall Qscore according to different categories of phlebotomy procedures (P = 0.284). The results of preanalytical cases showed acceptable Cscore values for all cases (89-96). Conclusion First two years of preanalytical EQA showed good compliance with the NRP and excellent expertise in resolving complex preanalytical issues. Major critical spots are lack of availability of safe-sharp needles, disposable tourniquets and glucose inhibitor tubes. PMID:28392736

  7. Dried blood spot specimen quality and validation of a new pre-analytical processing method for qualitative HIV-1 PCR, KwaZulu-Natal, South Africa

    PubMed Central

    Parboosing, Raveen; Siyaca, Ntombizandile; Moodley, Pravikrishnen

    2016-01-01

    Background Poor quality dried blood spot (DBS) specimens are usually rejected by virology laboratories, affecting early infant diagnosis of HIV. The practice of combining two incompletely-filled DBS in one specimen preparation tube during pre-analytical specimen processing (i.e., the two-spot method) has been implemented to reduce the number of specimens being rejected for insufficient volume. Objectives This study analysed laboratory data to describe the quality of DBS specimens and the use of the two-spot method over a one-year period, then validated the two-spot method against the standard (one-spot) method. Methods Data on HIV-1 PCR test requests submitted in 2014 to the Department of Virology at Inkosi Albert Luthuli Central Hospital in KwaZulu-Natal province, South Africa were analysed to describe reasons for specimen rejection, as well as results of the two-spot method. The accuracy, lower limit of detection and precision of the two-spot method were assessed. Results Of the 88 481 specimens received, 3.7% were rejected for pre-analytical problems. Of those, 48.9% were rejected as a result of insufficient specimen volume. Two health facilities had significantly more specimen rejections than other facilities. The two-spot method prevented 10 504 specimen rejections. The Pearson correlation coefficient comparing the standard to the two-spot method was 0.997. Conclusions The two-spot method was comparable with the standard method of pre-analytical specimen processing. Two health facilities were identified for targeted retraining on specimen quality. The two-spot method of DBS specimen processing can be used as an adjunct to retraining, to reduce the number of specimens rejected and improve linkage to care. PMID:28879108

  8. Dried blood spot specimen quality and validation of a new pre-analytical processing method for qualitative HIV-1 PCR, KwaZulu-Natal, South Africa.

    PubMed

    Govender, Kerusha; Parboosing, Raveen; Siyaca, Ntombizandile; Moodley, Pravikrishnen

    2016-01-01

    Poor quality dried blood spot (DBS) specimens are usually rejected by virology laboratories, affecting early infant diagnosis of HIV. The practice of combining two incompletely-filled DBS in one specimen preparation tube during pre-analytical specimen processing (i.e., the two-spot method) has been implemented to reduce the number of specimens being rejected for insufficient volume. This study analysed laboratory data to describe the quality of DBS specimens and the use of the two-spot method over a one-year period, then validated the two-spot method against the standard (one-spot) method. Data on HIV-1 PCR test requests submitted in 2014 to the Department of Virology at Inkosi Albert Luthuli Central Hospital in KwaZulu-Natal province, South Africa were analysed to describe reasons for specimen rejection, as well as results of the two-spot method. The accuracy, lower limit of detection and precision of the two-spot method were assessed. Of the 88 481 specimens received, 3.7% were rejected for pre-analytical problems. Of those, 48.9% were rejected as a result of insufficient specimen volume. Two health facilities had significantly more specimen rejections than other facilities. The two-spot method prevented 10 504 specimen rejections. The Pearson correlation coefficient comparing the standard to the two-spot method was 0.997. The two-spot method was comparable with the standard method of pre-analytical specimen processing. Two health facilities were identified for targeted retraining on specimen quality. The two-spot method of DBS specimen processing can be used as an adjunct to retraining, to reduce the number of specimens rejected and improve linkage to care.

  9. [Quality Management and Quality Specifications of Laboratory Tests in Clinical Studies--Challenges in Pre-Analytical Processes in Clinical Laboratories].

    PubMed

    Ishibashi, Midori

    2015-01-01

    The cost, speed, and quality are the three important factors recently indicated by the Ministry of Health, Labour and Welfare (MHLW) for the purpose of accelerating clinical studies. Based on this background, the importance of laboratory tests is increasing, especially in the evaluation of clinical study participants' entry and safety, and drug efficacy. To assure the quality of laboratory tests, providing high-quality laboratory tests is mandatory. For providing adequate quality assurance in laboratory tests, quality control in the three fields of pre-analytical, analytical, and post-analytical processes is extremely important. There are, however, no detailed written requirements concerning specimen collection, handling, preparation, storage, and shipping. Most laboratory tests for clinical studies are performed onsite in a local laboratory; however, a part of laboratory tests is done in offsite central laboratories after specimen shipping. As factors affecting laboratory tests, individual and inter-individual variations are well-known. Besides these factors, standardizing the factors of specimen collection, handling, preparation, storage, and shipping, may improve and maintain the high quality of clinical studies in general. Furthermore, the analytical method, units, and reference interval are also important factors. It is concluded that, to overcome the problems derived from pre-analytical processes, it is necessary to standardize specimen handling in a broad sense.

  10. Preanalytical Errors in Hematology Laboratory- an Avoidable Incompetence.

    PubMed

    HarsimranKaur, Vikram Narang; Selhi, Pavneet Kaur; Sood, Neena; Singh, Aminder

    2016-01-01

    Quality assurance in the hematology laboratory is a must to ensure laboratory users of reliable test results with high degree of precision and accuracy. Even after so many advances in hematology laboratory practice, pre-analytical errors remain a challenge for practicing pathologists. This study was undertaken with an objective to evaluate the types and frequency of preanalytical errors in hematology laboratory of our center. All the samples received in the Hematology Laboratory of Dayanand Medical College and Hospital, Ludhiana, India over a period of one year (July 2013-July 2014) were included in the study and preanalytical variables like clotted samples, quantity not sufficient, wrong sample, without label, wrong label were studied. Of 471,006 samples received in the laboratory, preanalytical errors, as per the above mentioned categories was found in 1802 samples. The most common error was clotted samples (1332 samples, 0.28% of the total samples) followed by quantity not sufficient (328 sample, 0.06%), wrong sample (96 samples, 0.02%), without label (24 samples, 0.005%) and wrong label (22 samples, 0.005%). Preanalytical errors are frequent in laboratories and can be corrected by regular analysis of the variables involved. Rectification can be done by regular education of the staff.

  11. Prevalence of Pre-Analytical Errors in Clinical Chemistry Diagnostic Labs in Sulaimani City of Iraqi Kurdistan

    PubMed Central

    2017-01-01

    Background Laboratory testing is roughly divided into three phases: a pre-analytical phase, an analytical phase and a post-analytical phase. Most analytical errors have been attributed to the analytical phase. However, recent studies have shown that up to 70% of analytical errors reflect the pre-analytical phase. The pre-analytical phase comprises all processes from the time a laboratory request is made by a physician until the specimen is analyzed at the lab. Generally, the pre-analytical phase includes patient preparation, specimen transportation, specimen collection and storage. In the present study, we report the first comprehensive assessment of the frequency and types of pre-analytical errors at the Sulaimani diagnostic labs in Iraqi Kurdistan. Materials and Methods Over 2 months, 5500 venous blood samples were observed in 10 public diagnostic labs of Sulaimani City. The percentages of rejected samples and types of sample inappropriateness were evaluated. The percentage of each of the following pre-analytical errors were recorded: delay in sample transportation, clotted samples, expired reagents, hemolyzed samples, samples not on ice, incorrect sample identification, insufficient sample, tube broken in centrifuge, request procedure errors, sample mix-ups, communication conflicts, misinterpreted orders, lipemic samples, contaminated samples and missed physician’s request orders. The difference between the relative frequencies of errors observed in the hospitals considered was tested using a proportional Z test. In particular, the survey aimed to discover whether analytical errors were recorded and examine the types of platforms used in the selected diagnostic labs. Results The analysis showed a high prevalence of improper sample handling during the pre-analytical phase. In appropriate samples, the percentage error was as high as 39%. The major reasons for rejection were hemolyzed samples (9%), incorrect sample identification (8%) and clotted samples (6%). Most quality control schemes at Sulaimani hospitals focus only on the analytical phase, and none of the pre-analytical errors were recorded. Interestingly, none of the labs were internationally accredited; therefore, corrective actions are needed at these hospitals to ensure better health outcomes. Internal and External Quality Assessment Schemes (EQAS) for the pre-analytical phase at Sulaimani clinical laboratories should be implemented at public hospitals. Furthermore, lab personnel, particularly phlebotomists, need continuous training on the importance of sample quality to obtain accurate test results. PMID:28107395

  12. Prevalence of Pre-Analytical Errors in Clinical Chemistry Diagnostic Labs in Sulaimani City of Iraqi Kurdistan.

    PubMed

    Najat, Dereen

    2017-01-01

    Laboratory testing is roughly divided into three phases: a pre-analytical phase, an analytical phase and a post-analytical phase. Most analytical errors have been attributed to the analytical phase. However, recent studies have shown that up to 70% of analytical errors reflect the pre-analytical phase. The pre-analytical phase comprises all processes from the time a laboratory request is made by a physician until the specimen is analyzed at the lab. Generally, the pre-analytical phase includes patient preparation, specimen transportation, specimen collection and storage. In the present study, we report the first comprehensive assessment of the frequency and types of pre-analytical errors at the Sulaimani diagnostic labs in Iraqi Kurdistan. Over 2 months, 5500 venous blood samples were observed in 10 public diagnostic labs of Sulaimani City. The percentages of rejected samples and types of sample inappropriateness were evaluated. The percentage of each of the following pre-analytical errors were recorded: delay in sample transportation, clotted samples, expired reagents, hemolyzed samples, samples not on ice, incorrect sample identification, insufficient sample, tube broken in centrifuge, request procedure errors, sample mix-ups, communication conflicts, misinterpreted orders, lipemic samples, contaminated samples and missed physician's request orders. The difference between the relative frequencies of errors observed in the hospitals considered was tested using a proportional Z test. In particular, the survey aimed to discover whether analytical errors were recorded and examine the types of platforms used in the selected diagnostic labs. The analysis showed a high prevalence of improper sample handling during the pre-analytical phase. In appropriate samples, the percentage error was as high as 39%. The major reasons for rejection were hemolyzed samples (9%), incorrect sample identification (8%) and clotted samples (6%). Most quality control schemes at Sulaimani hospitals focus only on the analytical phase, and none of the pre-analytical errors were recorded. Interestingly, none of the labs were internationally accredited; therefore, corrective actions are needed at these hospitals to ensure better health outcomes. Internal and External Quality Assessment Schemes (EQAS) for the pre-analytical phase at Sulaimani clinical laboratories should be implemented at public hospitals. Furthermore, lab personnel, particularly phlebotomists, need continuous training on the importance of sample quality to obtain accurate test results.

  13. Guidelines for the standardization of preanalytic variables for blood-based biomarker studies in Alzheimer’s disease research

    PubMed Central

    Gupta, Veer; Henriksen, Kim; Edwards, Melissa; Jeromin, Andreas; Lista, Simone; Bazenet, Chantal; Soares, Holly; Lovestone, Simon; Hampel, Harald; Montine, Thomas; Blennow, Kaj; Foroud, Tatiana; Carrillo, Maria; Graff-Radford, Neill; Laske, Christoph; Breteler, Monique; Shaw, Leslie; Trojanowski, John Q.; Schupf, Nicole; Rissman, Robert A.; Fagan, Anne M.; Oberoi, Pankaj; Umek, Robert; Weiner, Michael W.; Grammas, Paula; Posner, Holly; Martins, Ralph

    2015-01-01

    The lack of readily available biomarkers is a significant hindrance towards progressing to effective therapeutic and preventative strategies for Alzheimer’s disease (AD). Blood-based biomarkers have potential to overcome access and cost barriers and greatly facilitate advanced neuroimaging and cerebrospinal fluid biomarker approaches. Despite the fact that preanalytical processing is the largest source of variability in laboratory testing, there are no currently available standardized preanalytical guidelines. The current international working group provides the initial starting point for such guidelines for standardized operating procedures (SOPs). It is anticipated that these guidelines will be updated as additional research findings become available. The statement provides (1) a synopsis of selected preanalytical methods utilized in many international AD cohort studies, (2) initial draft guidelines/SOPs for preanalytical methods, and (3) a list of required methodological information and protocols to be made available for publications in the field in order to foster cross-validation across cohorts and laboratories. PMID:25282381

  14. Preanalytical quality in clinical chemistry laboratory.

    PubMed

    Ahmad, M Imteyaz; Ramesh, K L; Kumar, Ravi

    2014-01-01

    Haemolysis is usually caused by inadequate specimen collection or preanalytical handling and is suggested to be a suitable indicator of preanalytical quality. We investigated the prevalence of detectable haemolysis in all routine venous blood samples in OPDs and IPDs to identify differences in preanalytical quality. Haemolysis index (HI) values were obtained from a Vitros 5,1 in the routine clinical chemistry laboratory for samples collected in the outpatient department (OPD) collection centres, a hospital, and inpatient departments (IPD). Haemolysis was defined as a HI > or = 15 (detection limit). Samples from the OPD with the highest prevalence of haemolysis were 6.1 times (95% confidence interval (CI) 4.0 - 9.2) more often haemolysed compared to the center with the lowest prevalence. Of the samples collected in primary health care, 10.4% were haemolysed compared to 31.1% in the IPDs (p = 0.001). A notable difference in haemolysed samples was found between the IPDs section staffed by emergency medicine physicians and the section staffed by primary health care physicians (34.8% vs. 11.3%, p = 0.001). The significant variation in haemolysis indices among the investigated units is likely to reflect varying preanalytical conditions. The HI is a valuable tool for estimation and follow-up of preanalytical quality in the health care laboratory.

  15. Pre-analytical and analytical variation of drug determination in segmented hair using ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Nielsen, Marie Katrine Klose; Johansen, Sys Stybe; Linnet, Kristian

    2014-01-01

    Assessment of total uncertainty of analytical methods for the measurements of drugs in human hair has mainly been derived from the analytical variation. However, in hair analysis several other sources of uncertainty will contribute to the total uncertainty. Particularly, in segmental hair analysis pre-analytical variations associated with the sampling and segmentation may be significant factors in the assessment of the total uncertainty budget. The aim of this study was to develop and validate a method for the analysis of 31 common drugs in hair using ultra-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) with focus on the assessment of both the analytical and pre-analytical sampling variations. The validated method was specific, accurate (80-120%), and precise (CV≤20%) across a wide linear concentration range from 0.025-25 ng/mg for most compounds. The analytical variation was estimated to be less than 15% for almost all compounds. The method was successfully applied to 25 segmented hair specimens from deceased drug addicts showing a broad pattern of poly-drug use. The pre-analytical sampling variation was estimated from the genuine duplicate measurements of two bundles of hair collected from each subject after subtraction of the analytical component. For the most frequently detected analytes, the pre-analytical variation was estimated to be 26-69%. Thus, the pre-analytical variation was 3-7 folds larger than the analytical variation (7-13%) and hence the dominant component in the total variation (29-70%). The present study demonstrated the importance of including the pre-analytical variation in the assessment of the total uncertainty budget and in the setting of the 95%-uncertainty interval (±2CVT). Excluding the pre-analytical sampling variation could significantly affect the interpretation of results from segmental hair analysis. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  16. Preanalytical Nonconformity Management Regarding Primary Tube Mixing in Brazil.

    PubMed

    Lima-Oliveira, Gabriel; Cesare Guidi, Gian; Guimaraes, Andre Valpassos Pacifici; Abol Correa, Jose; Lippi, Giuseppe

    2017-01-01

    The multifaceted clinical laboratory process is divided in three essential phases: the preanalytical, analytical and postanalytical phase. Problems emerging from the preanalytical phase are responsible for more than 60% of laboratory errors. This report is aimed at highlighting and discussing nonconformity (e.g., nonstandardized procedures) in primary blood tube mixing immediately after blood collection by venipuncture with evacuated tube systems. From January 2015 to December 2015, fifty different laboratory quality managers from Brazil were contacted to request their internal audit reports on nonconformity regarding primary blood tube mixing immediately after blood collection by venipuncture performed using evacuated tube systems. A minority of internal audits (i.e., 4%) concluded that evacuated blood tubes were not accurately mixed after collection, whereas more than half of them reported that evacuated blood tubes were vigorously mixed immediately after collection, thus magnifying the risk of producing spurious hemolysis. Despite the vast ma jority of centers declaring that evacuated blood tubes were mixed gently and carefully, the overall number of inversions was found to be different from that recommended by the manufacturer. Since the turbulence generated by the standard vacuum pressure inside the primary evacuated tubes seems to be sufficient for providing solubilization, mixing and stabilization between additives and blood during venipuncture, avoidance of primary tube mixing probably does not introduce a major bias in tests results and may not be considered a nonconformity during audits for accreditation.

  17. Intensive educational efforts combined with external quality assessment improve the preanalytical phase in general practitioner offices and nursing homes.

    PubMed

    Sølvik, Una Ørvim; Bjelkarøy, Wenche Iren; Berg, Kari van den; Saga, Anne Lise; Hager, Helle Borgstrøm; Sandberg, Sverre

    2017-10-26

    Errors in the preanalytical phase in clinical laboratories affect patient safety. The aim of this study was to evaluate the effect of intensive educational efforts together with external quality assessment (EQA) of the preanalytical phase from 2013 to 2015 to improve patient identification in primary health care in Norway. In addition, routines for venous and capillary blood sampling were investigated. A preanalytical EQA was circulated in 2013 by the Norwegian Quality Improvement of Laboratory Examinations (Noklus) to general practitioner offices and nursing homes (n=2000) to obtain information about important issues to focus on before launching an intensive educational program with courses, posters and visits in 2013-2015. Preanalytical EQA surveys were further circulated in 2014 and 2015. The response rate varied between 42% and 55%. The percentages of participants asking for the patients' name and the Norwegian identification number increased from about 8% in 2013 to about 35% in 2015. The increase was similar for those participating in only one EQA survey and for those who participated in EQA surveys both in 2013 and 2015. Guidelines for venous and capillary blood sampling were not always followed. Educational efforts more than the preanalytical EQA influenced the actions and resulted in an increase in the percentages of participants that followed the guidelines for patient identification. Some aspects of blood sampling routines need improvement.

  18. Measuring myokines with cardiovascular functions: pre-analytical variables affecting the analytical output.

    PubMed

    Lombardi, Giovanni; Sansoni, Veronica; Banfi, Giuseppe

    2017-08-01

    In the last few years, a growing number of molecules have been associated to an endocrine function of the skeletal muscle. Circulating myokine levels, in turn, have been associated with several pathophysiological conditions including the cardiovascular ones. However, data from different studies are often not completely comparable or even discordant. This would be due, at least in part, to the whole set of situations related to the preparation of the patient prior to blood sampling, blood sampling procedure, processing and/or store. This entire process constitutes the pre-analytical phase. The importance of the pre-analytical phase is often not considered. However, in routine diagnostics, the 70% of the errors are in this phase. Moreover, errors during the pre-analytical phase are carried over in the analytical phase and affects the final output. In research, for example, when samples are collected over a long time and by different laboratories, a standardized procedure for sample collecting and the correct procedure for sample storage are acknowledged. In this review, we discuss the pre-analytical variables potentially affecting the measurement of myokines with cardiovascular functions.

  19. MS-based monitoring of proteolytic decay of synthetic reporter peptides for quality control of plasma and serum specimens.

    PubMed

    Findeisen, Peter; Thumfart, Jörg Oliver; Costina, Victor; Hofheinz, Ralf; Neumaier, Michael

    2013-09-01

    To determine the preanalytical quality of serum and plasma by monitoring the time-dependent ex vivo decay of a synthetic reporter peptide (RP) with liquid chromatography/mass spectrometry (LC/MS). Serum and plasma specimens were spiked with the RP and proteolytic fragments were monitored with LC/MS at different preanalytical time points ranging from 2 to 24 hours after blood withdrawal. The concentration of fragments changed in a time-dependent manner, and respective peptide profiles were used to classify specimens according to their preanalytical time span. Classification accuracy was high, with values always above 0.89 for areas under receiver operating characteristic curves. This "proteomics degradation clock" can be used to estimate the preanalytical quality of serum and plasma and might have impact on quality control procedures of biobanking repositories.

  20. Quantitative assessment of prevalence of pre-analytical variables and their effect on coagulation assay. Can intervention improve patient safety?

    PubMed

    Bhushan, Ravi; Sen, Arijit

    2017-04-01

    Very few Indian studies exist on evaluation of pre-analytical variables affecting "Prothrombin Time" the commonest coagulation assay performed. The study was performed in an Indian tertiary care setting with an aim to assess quantitatively the prevalence of pre-analytical variables and their effects on the results (patient safety), for Prothrombin time test. The study also evaluated their effects on the result and whether intervention, did correct the results. The firstly evaluated the prevalence for various pre-analytical variables detected in samples sent for Prothrombin Time testing. These samples with the detected variables wherever possible were tested and result noted. The samples from the same patients were repeated and retested ensuring that no pre-analytical variable is present. The results were again noted to check for difference the intervention produced. The study evaluated 9989 samples received for PT/INR over a period of 18 months. The prevalence of different pre-analytical variables was found to be 862 (8.63%). The proportion of various pre-analytical variables detected were haemolysed samples 515 (5.16%), over filled vacutainers 62 (0.62%), under filled vacutainers 39 (0.39%), low values 205 (2.05%), clotted samples 11 (0.11%), wrong labeling 4 (0.04%), wrong vacutainer use 2 (0.02%), chylous samples 7 (0.07%) and samples with more than one variable 17 (0.17%). The comparison of percentage of samples showing errors were noted for the first variables since they could be tested with and without the variable in place. The reduction in error percentage was 91.5%, 69.2%, 81.5% and 95.4% post intervention for haemolysed, overfilled, under filled and samples collected with excess pressure at phlebotomy respectively. Correcting the variables did reduce the error percentage to a great extent in these four variables and hence the variables are found to affect "Prothrombin Time" testing and can hamper patient safety.

  1. [Pre-analytical quality in fluid samples cytopathology: Results of a survey from the French Society of Clinical Cytology].

    PubMed

    Courtade-Saïdi, Monique; Fleury Feith, Jocelyne

    2015-10-01

    The pre-analytical step includes sample collection, preparation, transportation and storage in the pathology unit where the diagnosis is performed. The pathologist ensures that pre-analytical conditions are in line with expectations. The lack of standardization for handling cytological samples makes this pre-analytical step difficult to harmonize. Moreover, this step depends on the nature of the sample: fresh liquid or fixed material, air-dried smears, liquid-based cytology. The aim of the study was to review the different practices in French structures of pathology on the pre-analytical phase concerning cytological fluids such as broncho-alveolar lavage (BALF), serous fluids and urine. A survey was conducted on the basis of the pre-analytical chapter of the ISO 15189 and sent to 191 French pathological structures (105 public and 86 private). Fifty-six laboratories replied to the survey. Ninety-five per cent have a computerized management system and 70% a manual on sample handling. The general instructions requested for the patients and sample identification were highly correctly filled with a short time routing and additional tests prescription. By contrast, information are variable concerning the clinical information requested and the type of tubes for collecting fluids and the volumes required as well as the actions taken in case of non-conformity. For the specific items concerning BALF, serous fluids and urine, this survey has shown a great heterogeneity according to sample collection, fixation and of clinical information. This survey demonstrates that the pre-analytical quality for BALF, serous fluids and urine is not optimal and that some corrections of the practices are recommended with a standardization of numerous steps in order to increase the reproducibility of additional tests such as immunocytochemistry, cytogenetic and molecular biology. Some recommendations have been written. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  2. Identification errors in the blood transfusion laboratory: a still relevant issue for patient safety.

    PubMed

    Lippi, Giuseppe; Plebani, Mario

    2011-04-01

    Remarkable technological advances and increased awareness have both contributed to decrease substantially the uncertainty of the analytical phase, so that the manually intensive preanalytical activities currently represent the leading sources of errors in laboratory and transfusion medicine. Among preanalytical errors, misidentification and mistransfusion are still regarded as a considerable problem, posing serious risks for patient health and carrying huge expenses for the healthcare system. As such, a reliable policy of risk management should be readily implemented, developing through a multifaceted approach to prevent or limit the adverse outcomes related to transfusion reactions from blood incompatibility. This strategy encompasses root cause analysis, compliance with accreditation requirements, strict adherence to standard operating procedures, guidelines and recommendations for specimen collection, use of positive identification devices, rejection of potentially misidentified specimens, informatics data entry, query host communication, automated systems for patient identification and sample labeling and an adequate and safe environment. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. The knowledge and understanding of preanalytical phase among biomedicine students at the University of Zagreb.

    PubMed

    Dukic, Lora; Jokic, Anja; Kules, Josipa; Pasalic, Daria

    2016-01-01

    The educational program for health care personnel is important for reducing preanalytical errors and improving quality of laboratory test results. The aim of our study was to assess the level of knowledge on preanalytical phase in population of biomedicine students through a cross-sectional survey. A survey was sent to students on penultimate and final year of Faculty of Pharmacy and Biochemistry--study of medical biochemistry (FPB), Faculty of Veterinary Medicine (FVM) and School of Medicine (SM), University of Zagreb, Croatia, using the web tool SurveyMonkey. Survey was composed of demographics and 14 statements regarding the preanalytical phase of laboratory testing. Comparison of frequencies and proportions of correct answers was done with Fisher's exact test and test of comparison of proportions, respectively. Study included 135 participants, median age 24 (23-40) years. Students from FPB had higher proportion of correct answers (86%) compared to students from other biomedical faculties 62%, P < 0.001. Students from FPB were more conscious of the importance of specimen mixing (P = 0.027), prevalence of preanalytical errors (P = 0.001), impact of hemolysis (P = 0.032) and lipemia interferences (P = 0.010), proper choice of anticoagulants (P = 0.001), transport conditions for ammonia sample (P < 0.001) and order of draw during blood specimen collection (P < 0.001), in comparison with students from SM and FVM. Students from FPB are more conscious of the importance of preanalytical phase of testing in comparison with their colleagues from other biomedical faculties. No difference in knowledge between penultimate and final year of the same faculty was found.

  4. Evaluation of Preanalytical Quality Indicators by Six Sigma and Pareto`s Principle.

    PubMed

    Kulkarni, Sweta; Ramesh, R; Srinivasan, A R; Silvia, C R Wilma Delphine

    2018-01-01

    Preanalytical steps are the major sources of error in clinical laboratory. The analytical errors can be corrected by quality control procedures but there is a need for stringent quality checks in preanalytical area as these processes are done outside the laboratory. Sigma value depicts the performance of laboratory and its quality measures. Hence in the present study six sigma and Pareto principle was applied to preanalytical quality indicators to evaluate the clinical biochemistry laboratory performance. This observational study was carried out for a period of 1 year from November 2015-2016. A total of 1,44,208 samples and 54,265 test requisition forms were screened for preanalytical errors like missing patient information, sample collection details in forms and hemolysed, lipemic, inappropriate, insufficient samples and total number of errors were calculated and converted into defects per million and sigma scale. Pareto`s chart was drawn using total number of errors and cumulative percentage. In 75% test requisition forms diagnosis was not mentioned and sigma value of 0.9 was obtained and for other errors like sample receiving time, stat and type of sample sigma values were 2.9, 2.6, and 2.8 respectively. For insufficient sample and improper ratio of blood to anticoagulant sigma value was 4.3. Pareto`s chart depicts out of 80% of errors in requisition forms, 20% is contributed by missing information like diagnosis. The development of quality indicators, application of six sigma and Pareto`s principle are quality measures by which not only preanalytical, the total testing process can be improved.

  5. Novel bone metabolism-associated hormones: the importance of the pre-analytical phase for understanding their physiological roles.

    PubMed

    Lombardi, Giovanni; Barbaro, Mosè; Locatelli, Massimo; Banfi, Giuseppe

    2017-06-01

    The endocrine function of bone is now a recognized feature of this tissue. Bone-derived hormones that modulate whole-body homeostasis, are being discovered as for the effects on bone of novel and classic hormones produced by other tissues become known. Often, however, the data regarding these last generation bone-derived or bone-targeting hormones do not give about a clear picture of their physiological roles or concentration ranges. A certain degree of uncertainty could stem from differences in the pre-analytical management of biological samples. The pre-analytical phase comprises a series of decisions and actions (i.e., choice of sample matrix, methods of collection, transportation, treatment and storage) preceding analysis. Errors arising in this phase will inevitably be carried over to the analytical phase where they can reduce the measurement accuracy, ultimately, leading discrepant results. While the pre-analytical phase is all important, in routine laboratory medicine, it is often not given due consideration in research and clinical trials. This is particularly true for novel molecules, such as the hormones regulating the endocrine function of bone. In this review we discuss the importance of the pre-analytical variables affecting the measurement of last generation bone-associated hormones and describe their, often debated and rarely clear physiological roles.

  6. The knowledge and understanding of preanalytical phase among biomedicine students at the University of Zagreb

    PubMed Central

    Dukic, Lora; Jokic, Anja; Kules, Josipa; Pasalic, Daria

    2016-01-01

    Introduction The educational program for health care personnel is important for reducing preanalytical errors and improving quality of laboratory test results. The aim of our study was to assess the level of knowledge on preanalytical phase in population of biomedicine students through a cross-sectional survey. Materials and methods A survey was sent to students on penultimate and final year of Faculty of Pharmacy and Biochemistry – study of medical biochemistry (FPB), Faculty of Veterinary Medicine (FVM) and School of Medicine (SM), University of Zagreb, Croatia, using the web tool SurveyMonkey. Survey was composed of demographics and 14 statements regarding the preanalytical phase of laboratory testing. Comparison of frequencies and proportions of correct answers was done with Fisher’s exact test and test of comparison of proportions, respectively. Results Study included 135 participants, median age 24 (23-40) years. Students from FPB had higher proportion of correct answers (86%) compared to students from other biomedical faculties 62%, P < 0.001. Students from FPB were more conscious of the importance of specimen mixing (P = 0.027), prevalence of preanalytical errors (P = 0.001), impact of hemolysis (P = 0.032) and lipemia interferences (P = 0.010), proper choice of anticoagulants (P = 0.001), transport conditions for ammonia sample (P < 0.001) and order of draw during blood specimen collection (P < 0.001), in comparison with students from SM and FVM. Conclusions Students from FPB are more conscious of the importance of preanalytical phase of testing in comparison with their colleagues from other biomedical faculties. No difference in knowledge between penultimate and final year of the same faculty was found. PMID:26981023

  7. Behavioral Problems in the Classroom and Underlying Language Difficulties

    ERIC Educational Resources Information Center

    Tommerdahl, Jodi; Semingson, Peggy

    2013-01-01

    Dealing with the behavioral problems of students is one of many dimensions of most educators' and schools' requirements. While research has repeatedly shown that a large number of children with behavior problems have underlying, unrecognized language difficulties, few schools have implemented programs where children with problem behavior are…

  8. Pre-analytic and analytic sources of variations in thiopurine methyltransferase activity measurement in patients prescribed thiopurine-based drugs: A systematic review.

    PubMed

    Loit, Evelin; Tricco, Andrea C; Tsouros, Sophia; Sears, Margaret; Ansari, Mohammed T; Booth, Ronald A

    2011-07-01

    Low thiopurine S-methyltransferase (TPMT) enzyme activity is associated with increased thiopurine drug toxicity, particularly myelotoxicity. Pre-analytic and analytic variables for TPMT genotype and phenotype (enzyme activity) testing were reviewed. A systematic literature review was performed, and diagnostic laboratories were surveyed. Thirty-five studies reported relevant data for pre-analytic variables (patient age, gender, race, hematocrit, co-morbidity, co-administered drugs and specimen stability) and thirty-three for analytic variables (accuracy, reproducibility). TPMT is stable in blood when stored for up to 7 days at room temperature, and 3 months at -30°C. Pre-analytic patient variables do not affect TPMT activity. Fifteen drugs studied to date exerted no clinically significant effects in vivo. Enzymatic assay is the preferred technique. Radiochemical and HPLC techniques had intra- and inter-assay coefficients of variation (CVs) below 10%. TPMT is a stable enzyme, and its assay is not affected by age, gender, race or co-morbidity. Copyright © 2011. Published by Elsevier Inc.

  9. History of the preanalytical phase: a personal view

    PubMed Central

    Guder, Walter G.

    2014-01-01

    In the 70ies of the last century, ther term “preanalytical phase” was introduced in the literature. This term describes all actions and aspects of the “brain to brain circle” of the medical laboratory diagnostic procedure happening before the analytical phase. The author describes his personal experiences in the early seventies and the following history of increasing awareness of this phase as the main cause of “laboratory errors”. This includes the definitions of influence and interference factors as well as the first publications in book, internet, CD-Rom and recent App form over the past 40 years. In addition, a short summary of previous developments as prerequesits of laboratory diagnostic actions is described from the middle age matula for urine collection to the blood collection tubes, anticoagulants and centrifuges. The short review gives a personal view on the possible causes of missing awareness of preanalytical causes of error and future aspects of new techniques in regulation of requests to introduction of quality assurance programs for preanalytical factors. PMID:24627712

  10. Influence of Pre-Analytical Factors on Thymus- and Activation-Regulated Chemokine Quantitation in Plasma

    PubMed Central

    Zhao, Xuemei; Delgado, Liliana; Weiner, Russell; Laterza, Omar F.

    2015-01-01

    Thymus- and activation-regulated chemokine (TARC) in serum/plasma associates with the disease activity of atopic dermatitis (AD), and is a promising tool for assessing the response to the treatment of the disease. TARC also exists within platelets, with elevated levels detectable in AD patients. We examined the effects of pre-analytical factors on the quantitation of TARC in human EDTA plasma. TARC levels in platelet-free plasma were significantly lower than those in platelet-containing plasma. After freeze-thaw, TARC levels increased in platelet-containing plasma, but remained unchanged in platelet-free plasma, suggesting TARC was released from the platelets during the freeze-thaw process. In contrast, TARC levels were stable in serum independent of freeze-thaw. These findings underscore the importance of pre-analytical factors to TARC quantitation. Plasma TARC levels should be measured in platelet-free plasma for accurate quantitation. Pre-analytical factors influence the quantitation, interpretation, and implementation of circulating TARC as a biomarker for the development of AD therapeutics. PMID:28936246

  11. Assessment of bedside transfusion practices at a tertiary care center: A step closer to controlling the chaos

    PubMed Central

    Khetan, Dheeraj; Katharia, Rahul; Pandey, Hem Chandra; Chaudhary, Rajendra; Harsvardhan, Rajesh; Pandey, Hemchandra; Sonkar, Atul

    2018-01-01

    BACKGROUND: Blood transfusion chain can be divided into three phases: preanalytical (patient bedside), analytical (steps done at transfusion services), and postanalytical (bedside). Majority (~70%) of events due to blood transfusion have been attributed to errors in bedside blood administration practices. Survey of bedside transfusion practices (pre-analytical and post analytical phase) was done to assess awareness and compliance to guidelines regarding requisition and administration of blood components. MATERIALS AND METHODS: Interview-based questionnaire of ward staff and observational survey of actual transfusion of blood components in total 26 wards of the institute was carried out during November–December 2013. All the collected data were coded (to maintain confidentiality) and analyzed using SPSS (v 20). For analysis, wards were divided into three categories: medical, surgical, and others (including all intensive care units). RESULTS: A total of 104 (33 resident doctors and 71 nursing) staff members were interviewed and observational survey could be conducted in 25 wards during the study period. In the preanalytical phase, major issues were as follows: lack of awareness for institute guidelines (80.6% not aware), improper sampling practices (67.3%), and prescription related (56.7%). In the postanalytical phase, major issues were found to be lack of consent for blood transfusion (72%), improper warming of blood component (~80%), and problems in storage and discarding of blood units. CONCLUSION: There is need to create awareness about policies and guidelines of bed side transfusion among the ward staff. Regular audits are necessary for compliance to guidelines among clinical staff. PMID:29563672

  12. 21 CFR 866.4070 - RNA Preanalytical Systems.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false RNA Preanalytical Systems. 866.4070 Section 866.4070 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents § 866...

  13. 21 CFR 866.4070 - RNA Preanalytical Systems.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false RNA Preanalytical Systems. 866.4070 Section 866.4070 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents § 866...

  14. 21 CFR 866.4070 - RNA Preanalytical Systems.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false RNA Preanalytical Systems. 866.4070 Section 866.4070 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents § 866...

  15. 21 CFR 866.4070 - RNA Preanalytical Systems.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false RNA Preanalytical Systems. 866.4070 Section 866.4070 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents § 866...

  16. 21 CFR 866.4070 - RNA Preanalytical Systems.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false RNA Preanalytical Systems. 866.4070 Section 866.4070 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents § 866...

  17. Review of Pre-Analytical Errors in Oral Glucose Tolerance Testing in a Tertiary Care Hospital.

    PubMed

    Nanda, Rachita; Patel, Suprava; Sahoo, Sibashish; Mohapatra, Eli

    2018-03-13

    The pre-pre-analytical and pre-analytical phases form a major chunk of the errors in a laboratory. The process has taken into consideration a very common procedure which is the oral glucose tolerance test to identify the pre-pre-analytical errors. Quality indicators provide evidence of quality, support accountability and help in the decision making of laboratory personnel. The aim of this research is to evaluate pre-analytical performance of the oral glucose tolerance test procedure. An observational study that was conducted overa period of three months, in the phlebotomy and accessioning unit of our laboratory using questionnaire that examined the pre-pre-analytical errors through a scoring system. The pre-analytical phase was analyzed for each sample collected as per seven quality indicators. About 25% of the population gave wrong answer with regard to the question that tested the knowledge of patient preparation. The appropriateness of test result QI-1 had the most error. Although QI-5 for sample collection had a low error rate, it is a very important indicator as any wrongly collected sample can alter the test result. Evaluating the pre-analytical and pre-pre-analytical phase is essential and must be conducted routinely on a yearly basis to identify errors and take corrective action and to facilitate their gradual introduction into routine practice.

  18. The preanalytical optimization of blood cultures: a review and the clinical importance of benchmarking in 5 Belgian hospitals.

    PubMed

    Willems, Elise; Smismans, Annick; Cartuyvels, Reinoud; Coppens, Guy; Van Vaerenbergh, Kristien; Van den Abeele, Anne-Marie; Frans, Johan

    2012-05-01

    Bloodstream infections remain a major challenge in medicine. Optimal detection of pathogens is only possible if the quality of preanalytical factors is thoroughly controlled. Since the laboratory is responsible for this preanalytical phase, the quality control of critical factors should be integrated in its quality control program. The numerous recommendations regarding blood culture collection contain controversies. Only an unambiguous guideline permits standardization and interlaboratory quality control. We present an evidence-based concise guideline of critical preanalytical determinants for blood culture collection and summarize key performance indicators with their concomitant target values. In an attempt to benchmark, we compared the true-positive rate, contamination rate, and collected blood volume of blood culture bottles in 5 Belgian hospital laboratories. The true-positive blood culture rate fell within previously defined acceptation criteria by Baron et al. (2005) in all 5 hospitals, whereas the contamination rate exceeded the target value in 4 locations. Most unexpected, in each of the 5 laboratories, more than one third of the blood culture bottles were incorrectly filled, irrespective of the manufacturer of the blood culture vials. As a consequence of this shortcoming, one manufacturer recently developed an automatic blood volume monitoring system. In conclusion, clear recommendations for standardized blood culture collection combined with quality control of critical factors of the preanalytical phase are essential for diagnostic blood culture improvement. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Inpatient preanalytic process improvements.

    PubMed

    Wagar, Elizabeth A; Phipps, Ron; Del Guidice, Robert; Middleton, Lavinia P; Bingham, John; Prejean, Cheryl; Johnson-Hamilton, Martha; Philip, Pheba; Le, Ngoc Han; Muses, Waheed

    2013-12-01

    Phlebotomy services are a common target for preanalytic improvements. Many new, quality engineering tools have recently been applied in clinical laboratories. However, data on relatively few projects have been published. This example describes a complete application of current, quality engineering tools to improve preanalytic phlebotomy services. To decrease the response time in the preanalytic inpatient laboratory by 25%, to reduce the number of incident reports related to preanalytic phlebotomy, and to make systematic process changes that satisfied the stakeholders. The Department of Laboratory Medicine, General Services Section, at the University of Texas MD Anderson Cancer Center (Houston) is responsible for inpatient phlebotomy in a 24-hour operation, which serves 689 inpatient beds. The study director was project director of the Division of Pathology and Laboratory Medicine's Quality Improvement Section and was assisted by 2 quality technologists and an industrial engineer from MD Anderson Office of Performance Improvement. After implementing each solution, using well-recognized, quality tools and metrics, the response time for blood collection decreased by 23%, which was close to meeting the original responsiveness goal of 25%. The response time between collection and arrival in the laboratory decreased by 8%. Applicable laboratory-related incident reports were reduced by 43%. Comprehensive application of quality tools, such as statistical control charts, Pareto diagrams, value-stream maps, process failure modes and effects analyses, fishbone diagrams, solution prioritization matrices, and customer satisfaction surveys can significantly improve preset goals for inpatient phlebotomy.

  20. Some imminent but overlooked preanalytical and analytical challenges currently facing biomarkers and companion diagnostics.

    PubMed

    Halim, Abdel-Baset

    2015-06-01

    An incredibly high failure rate in the pharmaceutical industry has positioned personalized medicine with its prerequisite drug-diagnostic codevelopment, commonly known as companion diagnostics (CDx), in the frontline as an potential rescuer. This hopefulness is potentiated by the recent major advances and competitiveness in molecular diagnostics, making laboratory tests widely accessible at affordable prices. If executed correctly, biomarkers and CDx can potentially help the drug industry by enhancing the probability of success and possibly accelerating time to market; help the diagnostics industry develop tests utilizing precious, clinically annotated human samples; and, more importantly, benefit patients by supporting accurate diagnosis and selection of the most efficacious and least toxic therapies. However, this spectacular road is not yet paved, and it faces an enormous number of challenges. This paper will list these challenges and highlight some critical problems with representative examples of imminent but still overlooked preanalytical and analytical variables that can defeat the whole purpose of biomarkers and CDx and mislead drug developers and clinicians. The paper will provide some suggestions for mitigation. © 2015 New York Academy of Sciences.

  1. The preanalytic phase in veterinary clinical pathology.

    PubMed

    Braun, Jean-Pierre; Bourgès-Abella, Nathalie; Geffré, Anne; Concordet, Didier; Trumel, Cathy

    2015-03-01

    This article presents the general causes of preanalytic variability with a few examples showing specialists and practitioners that special and improved care should be given to this too often neglected phase. The preanalytic phase of clinical pathology includes all the steps from specimen collection to analysis. It is the phase where most laboratory errors occur in human, and probably also in veterinary clinical pathology. Numerous causes may affect the validity of the results, including technical factors, such as the choice of anticoagulant, the blood vessel sampled, and the duration and conditions of specimen handling. While the latter factors can be defined, influence of biologic and physiologic factors such as feeding and fasting, stress, and biologic and endocrine rhythms can often not be controlled. Nevertheless, as many factors as possible should at least be documented. The importance of the preanalytic phase is often not given the necessary attention, although the validity of the results and consequent clinical decision making and medical management of animal patients would likely be improved if the quality of specimens submitted to the laboratory was optimized. © 2014 American Society for Veterinary Clinical Pathology.

  2. The Unrecognized Crisis: Library Reference Service at the Crossroads.

    ERIC Educational Resources Information Center

    Hernon, Peter

    1986-01-01

    Briefly describes fundamental problems with library reference service based on the findings of 20 separate studies using unobtrusive tests. An emphasis on quality of service, realistic goals, and effective managerial strategies are identified as possible resolutions of these problems. (CLB)

  3. Use of CTX-I and PINP as bone turnover markers: National Bone Health Alliance recommendations to standardize sample handling and patient preparation to reduce pre-analytical variability.

    PubMed

    Szulc, P; Naylor, K; Hoyle, N R; Eastell, R; Leary, E T

    2017-09-01

    The National Bone Health Alliance (NBHA) recommends standardized sample handling and patient preparation for C-terminal telopeptide of type I collagen (CTX-I) and N-terminal propeptide of type I procollagen (PINP) measurements to reduce pre-analytical variability. Controllable and uncontrollable patient-related factors are reviewed to facilitate interpretation and minimize pre-analytical variability. The IOF and the International Federation of Clinical Chemistry (IFCC) Bone Marker Standards Working Group have identified PINP and CTX-I in blood to be the reference markers of bone turnover for the fracture risk prediction and monitoring of osteoporosis treatment. Although used in clinical research for many years, bone turnover markers (BTM) have not been widely adopted in clinical practice primarily due to their poor within-subject and between-lab reproducibility. The NBHA Bone Turnover Marker Project team aim to reduce pre-analytical variability of CTX-I and PINP measurements through standardized sample handling and patient preparation. Recommendations for sample handling and patient preparations were made based on review of available publications and pragmatic considerations to reduce pre-analytical variability. Controllable and un-controllable patient-related factors were reviewed to facilitate interpretation and sample collection. Samples for CTX-I must be collected consistently in the morning hours in the fasted state. EDTA plasma is preferred for CTX-I for its greater sample stability. Sample collection conditions for PINP are less critical as PINP has minimal circadian variability and is not affected by food intake. Sample stability limits should be observed. The uncontrollable aspects (age, sex, pregnancy, immobility, recent fracture, co-morbidities, anti-osteoporotic drugs, other medications) should be considered in BTM interpretation. Adopting standardized sample handling and patient preparation procedures will significantly reduce controllable pre-analytical variability. The successful adoption of such recommendations necessitates the close collaboration of various stakeholders at the global stage, including the laboratories, the medical community, the reagent manufacturers and the regulatory agencies.

  4. Heparin removal by ecteola-cellulose pre-treatment enables the use of plasma samples for accurate measurement of anti-Yellow fever virus neutralizing antibodies.

    PubMed

    Campi-Azevedo, Ana Carolina; Peruhype-Magalhães, Vanessa; Coelho-Dos-Reis, Jordana Grazziela; Costa-Pereira, Christiane; Yamamura, Anna Yoshida; Lima, Sheila Maria Barbosa de; Simões, Marisol; Campos, Fernanda Magalhães Freire; de Castro Zacche Tonini, Aline; Lemos, Elenice Moreira; Brum, Ricardo Cristiano; de Noronha, Tatiana Guimarães; Freire, Marcos Silva; Maia, Maria de Lourdes Sousa; Camacho, Luiz Antônio Bastos; Rios, Maria; Chancey, Caren; Romano, Alessandro; Domingues, Carla Magda; Teixeira-Carvalho, Andréa; Martins-Filho, Olindo Assis

    2017-09-01

    Technological innovations in vaccinology have recently contributed to bring about novel insights for the vaccine-induced immune response. While the current protocols that use peripheral blood samples may provide abundant data, a range of distinct components of whole blood samples are required and the different anticoagulant systems employed may impair some properties of the biological sample and interfere with functional assays. Although the interference of heparin in functional assays for viral neutralizing antibodies such as the functional plaque-reduction neutralization test (PRNT), considered the gold-standard method to assess and monitor the protective immunity induced by the Yellow fever virus (YFV) vaccine, has been well characterized, the development of pre-analytical treatments is still required for the establishment of optimized protocols. The present study intended to optimize and evaluate the performance of pre-analytical treatment of heparin-collected blood samples with ecteola-cellulose (ECT) to provide accurate measurement of anti-YFV neutralizing antibodies, by PRNT. The study was designed in three steps, including: I. Problem statement; II. Pre-analytical steps; III. Analytical steps. Data confirmed the interference of heparin on PRNT reactivity in a dose-responsive fashion. Distinct sets of conditions for ECT pre-treatment were tested to optimize the heparin removal. The optimized protocol was pre-validated to determine the effectiveness of heparin plasma:ECT treatment to restore the PRNT titers as compared to serum samples. The validation and comparative performance was carried out by using a large range of serum vs heparin plasma:ECT 1:2 paired samples obtained from unvaccinated and 17DD-YFV primary vaccinated subjects. Altogether, the findings support the use of heparin plasma:ECT samples for accurate measurement of anti-YFV neutralizing antibodies. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. [Modal failure analysis and effects in the detection of errors in the transport of samples to the clinical laboratory].

    PubMed

    Parés-Pollán, L; Gonzalez-Quintana, A; Docampo-Cordeiro, J; Vargas-Gallego, C; García-Álvarez, G; Ramos-Rodríguez, V; Diaz Rubio-García, M P

    2014-01-01

    Owing to the decrease in values of biochemical glucose parameter in some samples from external extraction centres, and the risk this implies to patient safety; it was decided to apply an adaptation of the «Health Services Failure Mode and Effects Analysis» (HFMEA) to manage risk during the pre-analytical phase of sample transportation from external centres to clinical laboratories. A retrospective study of glucose parameter was conducted during two consecutive months. The analysis was performed in its different phases: to define the HFMEA topic, assemble the team, graphically describe the process, conduct a hazard analysis, design the intervention and indicators, and identify a person to be responsible for ensuring completion of each action. The results of glucose parameter in one of the transport routes, were significantly lower (P=.006). The errors and potential causes of this problem were analysed, and criteria of criticality and detectability were applied (score≥8) in the decision tree. It was decided to: develop a document management system; reorganise extractions and transport routes in some centres; quality control of the sample container ice-packs, and the time and temperature during transportation. This work proposes quality indicators for controlling time and temperature of transported samples in the pre-analytical phase. Periodic review of certain laboratory parameters can help to detect problems in transporting samples. The HFMEA technique is useful for the clinical laboratory. Copyright © 2013 SECA. Published by Elsevier Espana. All rights reserved.

  6. Pre-analytical Factors Influence Accuracy of Urine Spot Iodine Assessment in Epidemiological Surveys.

    PubMed

    Doggui, Radhouene; El Ati-Hellal, Myriam; Traissac, Pierre; El Ati, Jalila

    2018-03-26

    Urinary iodine concentration (UIC) is commonly used to assess iodine status of subjects in epidemiological surveys. As pre-analytical factors are an important source of measurement error and studies about this phase are scarce, our objective was to assess the influence of urine sampling conditions on UIC, i.e., whether the child ate breakfast or not, urine void rank of the day, and time span between last meal and urine collection. A nationwide, two-stage, stratified, cross-sectional study including 1560 children (6-12 years) was performed in 2012. UIC was determined by the Sandell-Kolthoff method. Pre-analytical factors were assessed from children's mothers by using a questionnaire. Association between iodine status and pre-analytical factors were adjusted for one another and socio-economic characteristics by multivariate linear and multinomial regression models (RPR: relative prevalence ratios). Skipping breakfast prior to morning urine sampling decreased UIC by 40 to 50 μg/L and the proportion of UIC < 100 μg/L was higher among children having those skipped breakfast (RPR = 3.2[1.0-10.4]). In unadjusted analyses, UIC was less among children sampled more than 5 h from their last meal. UIC decreased with rank of urine void (e.g., first vs. second, P < 0.001); also, the proportion of UIC < 100 μg/L was greater among 4th rank samples (vs. second RPR = 2.1[1.1-4.0]). Subjects' breakfast status and urine void rank should be accounted for when assessing iodine status. Providing recommendations to standardize pre-analytical factors is a key step toward improving accuracy and comparability of survey results for assessing iodine status from spot urine samples. These recommendations have to be evaluated by future research.

  7. [Pre-analytical stage for biomarker assessment in breast cancer: 2014 update of the GEFPICS' guidelines in France].

    PubMed

    MacGrogan, Gaëtan; Mathieu, Marie-Christine; Poulet, Bruno; Penault-Llorca, Frédérique; Vincent-Salomon, Anne; Roger, Pascal; Treilleux, Isabelle; Valent, Alexander; Antoine, Martine; Becette, Véronique; Bor, Catherine; Brabencova, Eva; Charafe-Jauffret, Emmanuelle; Chenard, Marie-Pierre; Dauplat, Marie-Mélanie; Delrée, Paul; Devouassoux, Mojgan; Fiche, Maryse; Fondrevelle, Marie-Eve; Fridman, Viviana; Garbar, Christian; Genin, Pascal; Ghnassia, Jean-Pierre; Haudebourg, Juliette; Laberge-Le Couteulx, Sophie; Loussouarn, Delphine; Maran-Gonzalez, Aurélie; Marcy, Myriam; Michenet, Patrick; Sagan, Christine; Trassard, Martine; Verriele, Véronique; Arnould, Laurent; Lacroix-Triki, Magali

    2014-10-01

    Biomarker assessment of breast cancer tumor samples is part of the routine workflow of pathology laboratories. International guidelines have recently been updated, with special regards to the pre-analytical steps that are critical for the quality of immunohistochemical and in situ hybridization procedures, whatever the biomarker analyzed. Fixation and specimen handling protocols must be standardized, validated and carefully tracked. Cooperation and training of the personnel involved in the specimen workflow (e.g. radiologists, surgeons, nurses, technicians and pathologists) are of paramount importance. The GEFPICS' update of the recommendations herein details and comments the different steps of the pre-analytical process. Application of these guidelines and participation to quality insurance programs are mandatory to ensure the correct evaluation of oncotheranostic biomarkers. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  8. Managing Chronic Pain in People with Learning Disabilities: A Case Study

    ERIC Educational Resources Information Center

    Lewis, Sarah; Bell, Dorothy; Gillanders, David

    2007-01-01

    Chronic pain is a prevalent, under-diagnosed problem in the learning disability population. This is in part due to communication problems, unrecognized pain behaviours and the effects of medication. As a consequence, chronic pain often goes untreated and causes ongoing distress. This paper initially describes the main research that has been…

  9. A guide for measurement of circulating metabolic hormones in rodents: Pitfalls during the pre-analytical phase

    PubMed Central

    Bielohuby, Maximilian; Popp, Sarah; Bidlingmaier, Martin

    2012-01-01

    Researchers analyse hormones to draw conclusions from changes in hormone concentrations observed under specific physiological conditions and to elucidate mechanisms underlying their biological variability. It is, however, frequently overlooked that also circumstances occurring after collection of biological samples can significantly affect the hormone concentrations measured, owing to analytical and pre-analytical variability. Whereas the awareness for such potential confounders is increasing in human laboratory medicine, there is sometimes limited consensus about the control of these factors in rodent studies. In this guide, we demonstrate how such factors can affect reliability and consequent interpretation of the data from immunoassay measurements of circulating metabolic hormones in rodent studies. We also compare the knowledge about such factors in rodent studies to recent recommendations established for biomarker studies in humans and give specific practical recommendations for the control of pre-analytical conditions in metabolic studies in rodents. PMID:24024118

  10. Exhaled breath condensate – from an analytical point of view

    PubMed Central

    Dodig, Slavica; Čepelak, Ivana

    2013-01-01

    Over the past three decades, the goal of many researchers is analysis of exhaled breath condensate (EBC) as noninvasively obtained sample. A total quality in laboratory diagnostic processes in EBC analysis was investigated: pre-analytical (formation, collection, storage of EBC), analytical (sensitivity of applied methods, standardization) and post-analytical (interpretation of results) phases. EBC analysis is still used as a research tool. Limitations referred to pre-analytical, analytical, and post-analytical phases of EBC analysis are numerous, e.g. low concentrations of EBC constituents, single-analyte methods lack in sensitivity, and multi-analyte has not been fully explored, and reference values are not established. When all, pre-analytical, analytical and post-analytical requirements are met, EBC biomarkers as well as biomarker patterns can be selected and EBC analysis can hopefully be used in clinical practice, in both, the diagnosis and in the longitudinal follow-up of patients, resulting in better outcome of disease. PMID:24266297

  11. Brief Report: Eosinophilic Esophagitis as a Cause of Feeding Problems in Autistic Boy. The First Reported Case

    ERIC Educational Resources Information Center

    Jarocka-Cyrta, Elzbieta; Wasilewska, Jolanta; Kaczmarski, Maciej Gustaw

    2011-01-01

    Unrecognized gastrointestinal disorders may contribute to the behavioral problems in non-verbal patients, but they are often overlooked since the clinical symptoms are nonspecific. Eosinophilic esophagitis (EE) is a chronic inflammatory disorder manifesting itself predominantly in reflux-type symptoms that do not respond to standard anti-reflux…

  12. Tissue is alive: New technologies are needed to address the problems of protein biomarker pre-analytical variability.

    PubMed

    Espina, Virginia; Mueller, Claudius; Edmiston, Kirsten; Sciro, Manuela; Petricoin, Emanuel F; Liotta, Lance A

    2009-08-01

    Instability of tissue protein biomarkers is a critical issue for molecular profiling. Pre-analytical variables during tissue procurement, such as time delays during which the tissue remains stored at room temperature, can cause significant variability and bias in downstream molecular analysis. Living tissue, ex vivo, goes through a defined stage of reactive changes that begin with oxidative, hypoxic and metabolic stress, and culminate in apoptosis. Depending on the delay time ex vivo, and reactive stage, protein biomarkers, such as signal pathway phosphoproteins will be elevated or suppressed in a manner which does not represent the biomarker levels at the time of excision. Proteomic data documenting reactive tissue protein changes post collection indicate the need to recognize and address tissue stability, preservation of post-translational modifications, and preservation of morphologic features for molecular analysis. Based on the analysis of phosphoproteins, one of the most labile tissue protein biomarkers, we set forth tissue procurement guidelines for clinical research. We propose technical solutions for (i) assessing the state of protein analyte preservation and specimen quality via identification of a panel of natural proteins (surrogate stability markers), and (ii) using multi-purpose fixative solution designed to stabilize, preserve and maintain proteins, nucleic acids, and tissue architecture.

  13. Tissue is alive: New technologies are needed to address the problems of protein biomarker pre-analytical variability

    PubMed Central

    Espina, Virginia; Mueller, Claudius; Edmiston, Kirsten; Sciro, Manuela; Petricoin, Emanuel F.; Liotta, Lance A.

    2010-01-01

    Instability of tissue protein biomarkers is a critical issue for molecular profiling. Pre-analytical variables during tissue procurement, such as time delays during which the tissue remains stored at room temperature, can cause significant variability and bias in downstream molecular analysis. Living tissue, ex vivo, goes through a defined stage of reactive changes that begin with oxidative, hypoxic and metabolic stress, and culminate in apoptosis. Depending on the delay time ex vivo, and reactive stage, protein biomarkers, such as signal pathway phosphoproteins will be elevated or suppressed in a manner which does not represent the biomarker levels at the time of excision. Proteomic data documenting reactive tissue protein changes post collection indicate the need to recognize and address tissue stability, preservation of post-translational modifications, and preservation of morphologic features for molecular analysis. Based on the analysis of phosphoproteins, one of the most labile tissue protein biomarkers, we set forth tissue procurement guidelines for clinical research. We propose technical solutions for (i) assessing the state of protein analyte preservation and specimen quality via identification of a panel of natural proteins (surrogate stability markers), and (ii) using multi-purpose fixative solution designed to stabilize, preserve and maintain proteins, nucleic acids, and tissue architecture. PMID:20871745

  14. Ethics in the laboratory examination of patients

    PubMed Central

    Nyrhinen, T.; Leino-Kilpi, H.

    2000-01-01

    Various value problems are connected with the clinical examination of patients. The purpose of this literature review is to clarify: 1) in which patient examinations ethical problems are generally found; 2) what kind of ethical problems are found in the different phases of the examination process, and 3) what kind of ethical problems are found in connection with the use of examination results. Genetic testing, autopsy, prenatal and HIV examinations were ethically the most problematic laboratory examinations. The most problematic phase in the laboratory examination process proved to be the pre-analytic phase. At present the results of laboratory examination are used more and more often for the prediction of diseases. The problems appear when the examination results are used for discrimination and stigmatisation. Because of the lack of empirical ethical research, it is important to chart empirical knowledge about present value conflict situations involved in the laboratory examination process. Key Words: Ethic • laboratory • test • examination • diagnosis • patient PMID:10701173

  15. Request Pattern, Pre-Analytical and Analytical Conditions of Urinalysis in Primary Care: Lessons from a One-Year Large-Scale Multicenter Study.

    PubMed

    Salinas, Maria; Lopez-Garrigos, Maite; Flores, Emilio; Leiva-Salinas, Carlos

    2018-06-01

    To study the urinalysis request, pre-analytical sample conditions, and analytical procedures. Laboratories were asked to provide the number of primary care urinalyses requested, and to fill out a questionnaire regarding pre-analytical conditions and analytical procedures. 110 laboratories participated in the study. 232.5 urinalyses/1,000 inhabitants were reported. 75.4% used the first morning urine. The sample reached the laboratory in less than 2 hours in 18.8%, between 2 - 4 hours in 78.3%, and between 4 - 6 hours in the remaining 2.9%. 92.5% combined the use of test strip and particle analysis, and only 7.5% used the strip exclusively. All participants except one performed automated particle analysis depending on strip results; in 16.2% the procedure was only manual. Urinalysis was highly requested. There was a lack of compliance with guidelines regarding time between micturition and analysis that usually involved the combination of strip followed by particle analysis.

  16. Variability in, variability out: best practice recommendations to standardize pre-analytical variables in the detection of circulating and tissue microRNAs.

    PubMed

    Khan, Jenna; Lieberman, Joshua A; Lockwood, Christina M

    2017-05-01

    microRNAs (miRNAs) hold promise as biomarkers for a variety of disease processes and for determining cell differentiation. These short RNA species are robust, survive harsh treatment and storage conditions and may be extracted from blood and tissue. Pre-analytical variables are critical confounders in the analysis of miRNAs: we elucidate these and identify best practices for minimizing sample variation in blood and tissue specimens. Pre-analytical variables addressed include patient-intrinsic variation, time and temperature from sample collection to storage or processing, processing methods, contamination by cells and blood components, RNA extraction method, normalization, and storage time/conditions. For circulating miRNAs, hemolysis and blood cell contamination significantly affect profiles; samples should be processed within 2 h of collection; ethylene diamine tetraacetic acid (EDTA) is preferred while heparin should be avoided; samples should be "double spun" or filtered; room temperature or 4 °C storage for up to 24 h is preferred; miRNAs are stable for at least 1 year at -20 °C or -80 °C. For tissue-based analysis, warm ischemic time should be <1 h; cold ischemic time (4 °C) <24 h; common fixative used for all specimens; formalin fix up to 72 h prior to processing; enrich for cells of interest; validate candidate biomarkers with in situ visualization. Most importantly, all specimen types should have standard and common workflows with careful documentation of relevant pre-analytical variables.

  17. NASA's Accident Precursor Analysis Process and the International Space Station

    NASA Technical Reports Server (NTRS)

    Groen, Frank; Lutomski, Michael

    2010-01-01

    This viewgraph presentation reviews the implementation of Accident Precursor Analysis (APA), as well as the evaluation of In-Flight Investigations (IFI) and Problem Reporting and Corrective Action (PRACA) data for the identification of unrecognized accident potentials on the International Space Station.

  18. Immunohistochemistry practices of cytopathology laboratories: a survey of participants in the College of American Pathologists Nongynecologic Cytopathology Education Program.

    PubMed

    Fischer, Andrew H; Schwartz, Mary R; Moriarty, Ann T; Wilbur, David C; Souers, Rhona; Fatheree, Lisa; Booth, Christine N; Clayton, Amy C; Kurtyz, Daniel F I; Padmanabhan, Vijayalakshmi; Crothers, Barbara A

    2014-09-01

    Immunohistochemistry (IHC) is important for cytology but poses special challenges because preanalytic conditions may differ from the conditions of IHC-positive controls. To broadly survey cytology laboratories to quantify preanalytic platforms for cytology IHC and identify problems with particular platforms or antigens. To discover how validation guidelines for HER2 testing have affected cytology. A voluntary survey of cytology IHC practices was sent to 1899 cytology laboratories participating in the College of American Pathologists Nongynecologic Cytopathology Education Program in the fall of 2009. A total of 818 laboratories (43%) responded to the survey by April 2010. Three hundred fourty-five of 791 respondents (44%) performed IHC on cytology specimens. Seventeen different fixation and processing platforms prior to antibody reaction were reported. A total of 59.2% of laboratories reported differences between the platforms for cytology specimens and positive controls, but most (155 of 184; 84%) did not alter antibody dilutions or antigen retrieval for cytology IHC. When asked to name 2 antibodies for which staining conditions differed between cytology and surgical samples, there were 18 responses listing 14 antibodies. A total of 30.6% of laboratories performing IHC offered HER2 testing before publication of the 2007 College of American Pathologists/American Society of Clinical Oncologists guidelines, compared with 33.6% afterward, with increased performance of testing by reference laboratories. Three laboratories validated a nonformalin HER2 platform. The platforms for cytology IHC and positive controls differ for most laboratories, yet conditions are uncommonly adjusted for cytology specimens. Except for the unsuitability of air-dried smears for HER2 testing, the survey did not reveal evidence of systematic problems with any antibody or platform.

  19. Quality of blood culture testing - a survey in intensive care units and microbiological laboratories across four European countries

    PubMed Central

    2013-01-01

    Introduction Blood culture (BC) testing before initiation of antimicrobial therapy is recommended as a standard of care in international sepsis guidelines and has been shown to reduce intensive care unit (ICU) stay, antibiotic use, and costs in hospitalized patients. Whereas microbiological laboratory practice has been highly standardized, shortfalls in the preanalytic procedures in the ICU (that is indication, time-to-incubation, blood volume and numbers of BC sets) have a significant effect on the diagnostic yield. The objective of this study was to gain insights into current practices regarding BC testing in intensive care units. Methods Qualitative survey, data collection by 138 semi-structured telephone interviews in four European countries (Italy, UK, France and Germany) between September and November 2009 in 79 clinical microbiology laboratories (LABs) and 59 ICUs. Results Whereas BC testing is expected to remain the gold standard for sepsis diagnostics in all countries, there are substantial differences regarding preanalytic procedures. The decision to launch BC testing is carried out by physicians vs. ICU nurses in the UK in 92 vs. 8%, in France in 75 vs. 25%, in Italy in 88 vs. 12% and in Germany in 92 vs. 8%. Physicians vs. nurses collect BCs in the UK in 77 vs. 23%, in France in 0 vs. 100%, in Italy in 6 vs. 94% and in Germany in 54 vs. 46%. The mean time from blood collection to incubation in the UK is 2 h, in France 3 h, in Italy 4 h, but 20 h in German remote LABs (2 h in in-house LABs), due to the large number of remote nonresident microbiological laboratories in Germany. There were major differences between the perception of the quality of BC testing between ICUs and LABs. Among German ICU respondents, 62% reported that they have no problems with BC testing, 15% reported time constraints, 15% cost pressure, and only 8% too long time to incubation. However, the corresponding LABs of these German ICUs reported too many false positive results due to preanalytical contaminations (49%), insufficient numbers of incoming BC sets (47%), long transportation time (41%) or cost pressure (18%). Conclusions There are considerable differences in the quality of BC testing across European countries. In Germany, time to incubation is a considerable problem due to the increasing number of remote LABs. This is a major issue of concern to physicians aiming to implement sepsis guidelines in the ICUs. PMID:24144084

  20. Impact of Educational Activities in Reducing Pre-Analytical Laboratory Errors

    PubMed Central

    Al-Ghaithi, Hamed; Pathare, Anil; Al-Mamari, Sahimah; Villacrucis, Rodrigo; Fawaz, Naglaa; Alkindi, Salam

    2017-01-01

    Objectives Pre-analytic errors during diagnostic laboratory investigations can lead to increased patient morbidity and mortality. This study aimed to ascertain the effect of educational nursing activities on the incidence of pre-analytical errors resulting in non-conforming blood samples. Methods This study was conducted between January 2008 and December 2015. All specimens received at the Haematology Laboratory of the Sultan Qaboos University Hospital, Muscat, Oman, during this period were prospectively collected and analysed. Similar data from 2007 were collected retrospectively and used as a baseline for comparison. Non-conforming samples were defined as either clotted samples, haemolysed samples, use of the wrong anticoagulant, insufficient quantities of blood collected, incorrect/lack of labelling on a sample or lack of delivery of a sample in spite of a sample request. From 2008 onwards, multiple educational training activities directed at the hospital nursing staff and nursing students primarily responsible for blood collection were implemented on a regular basis. Results After initiating corrective measures in 2008, a progressive reduction in the percentage of non-conforming samples was observed from 2009 onwards. Despite a 127.84% increase in the total number of specimens received, there was a significant reduction in non-conforming samples from 0.29% in 2007 to 0.07% in 2015, resulting in an improvement of 75.86% (P <0.050). In particular, specimen identification errors decreased by 0.056%, with a 96.55% improvement. Conclusion Targeted educational activities directed primarily towards hospital nursing staff had a positive impact on the quality of laboratory specimens by significantly reducing pre-analytical errors. PMID:29062553

  1. Planned Variation in Preanalytical Conditions to Evaluate Biospecimen Stability in the National Children’s Study (NCS)

    PubMed Central

    Mechanic, Leah; Mendez, Armando; Merrill, Lori; Rogers, John; Layton, Marnie; Todd, Deborah; Varanasi, Arti; O’Brien, Barbara; Meyer, William A.; Zhang, Ming; Schleicher, Rosemary L.; Moye, Jack

    2014-01-01

    BACKGROUND Preanalytical conditions encountered during collection, processing, and storage of biospecimens may influence laboratory results. The National Children’s Study (NCS) is a planned prospective cohort study of 100,000 families to examine the influence of a wide variety of exposures on child health. In developing biospecimen collection, processing, and storage procedures for the NCS, we identified several analytes of different biochemical categories for which it was unclear to what extent deviations from NCS procedures could influence measurement results. METHODS A pilot study was performed to examine effects of preanalytic sample handling conditions (delays in centrifugation, freezing delays, delays in separation from cells, additive delay, and tube type) on concentrations of eight different analytes. 2,825 measurements were made to assess 15 unique combinations of analyte and handling conditions in blood collected from 151 women of childbearing age (≥20 individuals per handling condition). RESULTS The majority of analytes were stable under the conditions evaluated. However, levels of plasma interleukin-6 and serum insulin were decreased in response to sample centrifugation delays of up to 5.5 hours post collection (P<0.0001). In addition, delays in freezing centrifuged plasma samples (comparing 24, 48 and 72 hours to immediate freezing) resulted in increased levels of adrenocorticotropic hormone (P=0.0014). CONCLUSIONS Determining stability of proposed analytes in response to preanalytical conditions and handling helps to ensure high-quality specimens for study now and in the future. The results inform development of procedures, plans for measurement of analytes, and interpretation of laboratory results. PMID:23924524

  2. Evaluation of analytical errors in a clinical chemistry laboratory: a 3 year experience.

    PubMed

    Sakyi, As; Laing, Ef; Ephraim, Rk; Asibey, Of; Sadique, Ok

    2015-01-01

    Proficient laboratory service is the cornerstone of modern healthcare systems and has an impact on over 70% of medical decisions on admission, discharge, and medications. In recent years, there is an increasing awareness of the importance of errors in laboratory practice and their possible negative impact on patient outcomes. We retrospectively analyzed data spanning a period of 3 years on analytical errors observed in our laboratory. The data covered errors over the whole testing cycle including pre-, intra-, and post-analytical phases and discussed strategies pertinent to our settings to minimize their occurrence. We described the occurrence of pre-analytical, analytical and post-analytical errors observed at the Komfo Anokye Teaching Hospital clinical biochemistry laboratory during a 3-year period from January, 2010 to December, 2012. Data were analyzed with Graph Pad Prism 5(GraphPad Software Inc. CA USA). A total of 589,510 tests was performed on 188,503 outpatients and hospitalized patients. The overall error rate for the 3 years was 4.7% (27,520/58,950). Pre-analytical, analytical and post-analytical errors contributed 3.7% (2210/58,950), 0.1% (108/58,950), and 0.9% (512/58,950), respectively. The number of tests reduced significantly over the 3-year period, but this did not correspond with a reduction in the overall error rate (P = 0.90) along with the years. Analytical errors are embedded within our total process setup especially pre-analytical and post-analytical phases. Strategic measures including quality assessment programs for staff involved in pre-analytical processes should be intensified.

  3. Exploring the initial steps of the testing process: frequency and nature of pre-preanalytic errors.

    PubMed

    Carraro, Paolo; Zago, Tatiana; Plebani, Mario

    2012-03-01

    Few data are available on the nature of errors in the so-called pre-preanalytic phase, the initial steps of the testing process. We therefore sought to evaluate pre-preanalytic errors using a study design that enabled us to observe the initial procedures performed in the ward, from the physician's test request to the delivery of specimens in the clinical laboratory. After a 1-week direct observational phase designed to identify the operating procedures followed in 3 clinical wards, we recorded all nonconformities and errors occurring over a 6-month period. Overall, the study considered 8547 test requests, for which 15 917 blood sample tubes were collected and 52 982 tests undertaken. No significant differences in error rates were found between the observational phase and the overall study period, but underfilling of coagulation tubes was found to occur more frequently in the direct observational phase (P = 0.043). In the overall study period, the frequency of errors was found to be particularly high regarding order transmission [29 916 parts per million (ppm)] and hemolysed samples (2537 ppm). The frequency of patient misidentification was 352 ppm, and the most frequent nonconformities were test requests recorded in the diary without the patient's name and failure to check the patient's identity at the time of blood draw. The data collected in our study confirm the relative frequency of pre-preanalytic errors and underline the need to consensually prepare and adopt effective standard operating procedures in the initial steps of laboratory testing and to monitor compliance with these procedures over time.

  4. Bias due to Preanalytical Dilution of Rodent Serum for Biochemical Analysis on the Siemens Dimension Xpand Plus

    PubMed Central

    Johns, Jennifer L.; Moorhead, Kaitlin A.; Hu, Jing; Moorhead, Roberta C.

    2018-01-01

    Clinical pathology testing of rodents is often challenging due to insufficient sample volume. One solution in clinical veterinary and exploratory research environments is dilution of samples prior to analysis. However, published information on the impact of preanalytical sample dilution on rodent biochemical data is incomplete. The objective of this study was to evaluate the effects of preanalytical sample dilution on biochemical analysis of mouse and rat serum samples utilizing the Siemens Dimension Xpand Plus. Rats were obtained from end of study research projects. Mice were obtained from sentinel testing programs. For both, whole blood was collected via terminal cardiocentesis into empty tubes and serum was harvested. Biochemical parameters were measured on fresh and thawed frozen samples run straight and at dilution factors 2–10. Dilutions were performed manually, utilizing either ultrapure water or enzyme diluent per manufacturer recommendations. All diluted samples were generated directly from the undiluted sample. Preanalytical dilution caused clinically unacceptable bias in most analytes at dilution factors four and above. Dilution-induced bias in total calcium, creatinine, total bilirubin, and uric acid was considered unacceptable with any degree of dilution, based on the more conservative of two definitions of acceptability. Dilution often caused electrolyte values to fall below assay range precluding evaluation of bias. Dilution-induced bias occurred in most biochemical parameters to varying degrees and may render dilution unacceptable in the exploratory research and clinical veterinary environments. Additionally, differences between results obtained at different dilution factors may confound statistical comparisons in research settings. Comparison of data obtained at a single dilution factor is highly recommended. PMID:29497614

  5. Impact of Educational Activities in Reducing Pre-Analytical Laboratory Errors: A quality initiative.

    PubMed

    Al-Ghaithi, Hamed; Pathare, Anil; Al-Mamari, Sahimah; Villacrucis, Rodrigo; Fawaz, Naglaa; Alkindi, Salam

    2017-08-01

    Pre-analytic errors during diagnostic laboratory investigations can lead to increased patient morbidity and mortality. This study aimed to ascertain the effect of educational nursing activities on the incidence of pre-analytical errors resulting in non-conforming blood samples. This study was conducted between January 2008 and December 2015. All specimens received at the Haematology Laboratory of the Sultan Qaboos University Hospital, Muscat, Oman, during this period were prospectively collected and analysed. Similar data from 2007 were collected retrospectively and used as a baseline for comparison. Non-conforming samples were defined as either clotted samples, haemolysed samples, use of the wrong anticoagulant, insufficient quantities of blood collected, incorrect/lack of labelling on a sample or lack of delivery of a sample in spite of a sample request. From 2008 onwards, multiple educational training activities directed at the hospital nursing staff and nursing students primarily responsible for blood collection were implemented on a regular basis. After initiating corrective measures in 2008, a progressive reduction in the percentage of non-conforming samples was observed from 2009 onwards. Despite a 127.84% increase in the total number of specimens received, there was a significant reduction in non-conforming samples from 0.29% in 2007 to 0.07% in 2015, resulting in an improvement of 75.86% ( P <0.050). In particular, specimen identification errors decreased by 0.056%, with a 96.55% improvement. Targeted educational activities directed primarily towards hospital nursing staff had a positive impact on the quality of laboratory specimens by significantly reducing pre-analytical errors.

  6. Analysis of Pre-Analytic Factors Affecting the Success of Clinical Next-Generation Sequencing of Solid Organ Malignancies.

    PubMed

    Chen, Hui; Luthra, Rajyalakshmi; Goswami, Rashmi S; Singh, Rajesh R; Roy-Chowdhuri, Sinchita

    2015-08-28

    Application of next-generation sequencing (NGS) technology to routine clinical practice has enabled characterization of personalized cancer genomes to identify patients likely to have a response to targeted therapy. The proper selection of tumor sample for downstream NGS based mutational analysis is critical to generate accurate results and to guide therapeutic intervention. However, multiple pre-analytic factors come into play in determining the success of NGS testing. In this review, we discuss pre-analytic requirements for AmpliSeq PCR-based sequencing using Ion Torrent Personal Genome Machine (PGM) (Life Technologies), a NGS sequencing platform that is often used by clinical laboratories for sequencing solid tumors because of its low input DNA requirement from formalin fixed and paraffin embedded tissue. The success of NGS mutational analysis is affected not only by the input DNA quantity but also by several other factors, including the specimen type, the DNA quality, and the tumor cellularity. Here, we review tissue requirements for solid tumor NGS based mutational analysis, including procedure types, tissue types, tumor volume and fraction, decalcification, and treatment effects.

  7. Congenital rubella syndrome in Haiti (Short communication).

    PubMed

    Golden, Nancy; Kempker, Russell; Khator, Parul; Summerlee, Robert; Fournier, Arthur

    2002-10-01

    To determine if there is an unrecognized problem of congenital rubella syndrome (CRS) in Haiti, a country without a national rubella immunization program. During March 2001 and June 2001, screening physicals were conducted on approximately 80 orphans at three orphanages in Haiti that accept disabled children. Children were classified as probable CRS cases based on established clinical criteria. Photo documentation of findings was obtained whenever possible. Six children met the criteria for probable CRS. Using data from surrounding Caribbean countries and from the United States of America prior to rubella immunization, we estimated that there are between 163 and 440 new cases of CRS per year in Haiti. CRS exists in Haiti, but its presence is generally unrecognized. A national rubella immunization policy should be considered.

  8. Case report of unexplained hypocalcaemia in a slightly haemolysed sample.

    PubMed

    Cornes, Michael

    2017-06-15

    The case presented highlights a common pre-analytical problem identified in the laboratory that was initially missed. It concerns a young, generally healthy adult patient with no significant medical history and no significant family history. They presented with common flu like symptoms to their primary care clinician who considered this was most likely a viral problem that would pass with time. The clinician, however, did some routine bloods to reassure the patient despite a lack of clinical indication. When the sample was analysed the sample was haemolysed with strikingly low calcium. This led to the patient being called into hospital for urgent repeat investigations, all of which turned out to be within normal ranges. On further investigation the original sample was found to be contaminated. This result would normally have been flagged but was missed due to the complication of haemolysis.

  9. Cognitive Behavioral Therapy for Insomnia in Older Adults

    ERIC Educational Resources Information Center

    Belanger, Lynda; LeBlanc, Melanie; Morin, Charles M.

    2012-01-01

    Insomnia is associated with significant morbidity and is often a persistent problem, particularly in older adults. It is important to attend to this complaint and not assume that it will remit spontaneously. In many cases, unfortunately, insomnia remains unrecognized and untreated, often because it is presumed that insomnia is an inevitable…

  10. Evaluation of Analytical Errors in a Clinical Chemistry Laboratory: A 3 Year Experience

    PubMed Central

    Sakyi, AS; Laing, EF; Ephraim, RK; Asibey, OF; Sadique, OK

    2015-01-01

    Background: Proficient laboratory service is the cornerstone of modern healthcare systems and has an impact on over 70% of medical decisions on admission, discharge, and medications. In recent years, there is an increasing awareness of the importance of errors in laboratory practice and their possible negative impact on patient outcomes. Aim: We retrospectively analyzed data spanning a period of 3 years on analytical errors observed in our laboratory. The data covered errors over the whole testing cycle including pre-, intra-, and post-analytical phases and discussed strategies pertinent to our settings to minimize their occurrence. Materials and Methods: We described the occurrence of pre-analytical, analytical and post-analytical errors observed at the Komfo Anokye Teaching Hospital clinical biochemistry laboratory during a 3-year period from January, 2010 to December, 2012. Data were analyzed with Graph Pad Prism 5(GraphPad Software Inc. CA USA). Results: A total of 589,510 tests was performed on 188,503 outpatients and hospitalized patients. The overall error rate for the 3 years was 4.7% (27,520/58,950). Pre-analytical, analytical and post-analytical errors contributed 3.7% (2210/58,950), 0.1% (108/58,950), and 0.9% (512/58,950), respectively. The number of tests reduced significantly over the 3-year period, but this did not correspond with a reduction in the overall error rate (P = 0.90) along with the years. Conclusion: Analytical errors are embedded within our total process setup especially pre-analytical and post-analytical phases. Strategic measures including quality assessment programs for staff involved in pre-analytical processes should be intensified. PMID:25745569

  11. Pre-Test and Post-Test Applications to Shape the Education of Phlebotomists in A Quality Management Program: An Experience in a Training Hospital

    PubMed Central

    Keşapli, Mustafa; Aydin, Özgür; Esen, Hatice; Yeğin, Ayşenur; Güngör, Faruk; Yilmaz, Necat

    2016-01-01

    Summary Background After the introduction of modern laboratory instruments and information systems, preanalytic phase is the new field of battle. Errors in preanalytical phase account for approximately half of total errors in clinical laboratory. The objective of this study was to share an experience of an education program that was believed to be successful in decreasing the number of rejected samples received from the Emergency Department (ED). Methods An education program about laboratory procedures, quality requirements in the laboratory, patient and health-care worker safety was planned by the quality team to be performed on 36 people who were responsible for sample collection in the ED. A questionary which included 11 questions about the preanalytic phase was applied to all the attendees before and after training. The number of rejected samples per million was discovered with right proportion account over the number of accepted and rejected samples to laboratory after and before the training period. Results Most of the attendees were nurses (n: 22/55%), with over 12 years of experience in general and 2–4 years experience in the ED. Knowledge level of the attendees was calculated before training as 58.9% and after training as 91.8%. While the total rate of sample rejection before training was 2.35% (sigma value 3.37–3.50), the rate after training was 1.56% (sigma value 3.62–3.75). Conclusions Increasing the knowledge of staff has a direct positive impact on the preanalytic phase. The application of a pre-test was observed to be a feasible tool to shape group specific education programs. PMID:28356887

  12. Pre-Test and Post-Test Applications to Shape the Education of Phlebotomists in A Quality Management Program: An Experience in a Training Hospital.

    PubMed

    Aykal, Güzin; Keşapli, Mustafa; Aydin, Özgür; Esen, Hatice; Yeğin, Ayşenur; Güngör, Faruk; Yilmaz, Necat

    2016-09-01

    After the introduction of modern laboratory instruments and information systems, preanalytic phase is the new field of battle. Errors in preanalytical phase account for approximately half of total errors in clinical laboratory. The objective of this study was to share an experience of an education program that was believed to be successful in decreasing the number of rejected samples received from the Emergency Department (ED). An education program about laboratory procedures, quality requirements in the laboratory, patient and health-care worker safety was planned by the quality team to be performed on 36 people who were responsible for sample collection in the ED. A questionary which included 11 questions about the preanalytic phase was applied to all the attendees before and after training. The number of rejected samples per million was discovered with right proportion account over the number of accepted and rejected samples to laboratory after and before the training period. Most of the attendees were nurses (n: 22/55%), with over 12 years of experience in general and 2-4 years experience in the ED. Knowledge level of the attendees was calculated before training as 58.9% and after training as 91.8%. While the total rate of sample rejection before training was 2.35% (sigma value 3.37-3.50), the rate after training was 1.56% (sigma value 3.62-3.75). Increasing the knowledge of staff has a direct positive impact on the preanalytic phase. The application of a pre-test was observed to be a feasible tool to shape group specific education programs.

  13. Drone inflight mixing of biochemical samples.

    PubMed

    Katariya, Mayur; Chung, Dwayne Chung Kim; Minife, Tristan; Gupta, Harshit; Zahidi, Alifa Afiah Ahmad; Liew, Oi Wah; Ng, Tuck Wah

    2018-03-15

    Autonomous systems for sample transport to the laboratory for analysis can be improved in terms of timeliness, cost and error mitigation in the pre-analytical testing phase. Drones have been reported for outdoor sample transport but incorporating devices on them to attain homogenous mixing of reagents during flight to enhance sample processing timeliness is limited by payload issues. It is shown here that flipping maneuvers conducted with quadcopters are able to facilitate complete and gentle mixing. This capability incorporated during automated sample transport serves to address an important factor contributing to pre-analytical variability which ultimately impacts on test result reliability. Copyright © 2018 Elsevier Inc. All rights reserved.

  14. Technical pre-analytical effects on the clinical biochemistry of Atlantic salmon (Salmo salar L.).

    PubMed

    Braceland, M; Houston, K; Ashby, A; Matthews, C; Haining, H; Rodger, H; Eckersall, P D

    2017-01-01

    Clinical biochemistry has long been utilized in human and veterinary medicine as a vital diagnostic tool, but despite occasional studies showing its usefulness in monitoring health status in Atlantic salmon (Salmo salar L.), it has not yet been widely utilized within the aquaculture industry. This is due, in part, to a lack of an agreed protocol for collection and processing of blood prior to analysis. Moreover, while the analytical phase of clinical biochemistry is well controlled, there is a growing understanding that technical pre-analytical variables can influence analyte concentrations or activities. In addition, post-analytical interpretation of treatment effects is variable in the literature, thus making the true effect of sample treatment hard to evaluate. Therefore, a number of pre-analytical treatments have been investigated to examine their effect on analyte concentrations and activities. In addition, reference ranges for salmon plasma biochemical analytes have been established to inform veterinary practitioners and the aquaculture industry of the importance of clinical biochemistry in health and disease monitoring. Furthermore, a standardized protocol for blood collection has been proposed. © 2016 The Authors Journal of Fish Diseases Published by John Wiley & Sons Ltd.

  15. Standard operating procedures for pre-analytical handling of blood and urine for metabolomic studies and biobanks.

    PubMed

    Bernini, Patrizia; Bertini, Ivano; Luchinat, Claudio; Nincheri, Paola; Staderini, Samuele; Turano, Paola

    2011-04-01

    (1)H NMR metabolic profiling of urine, serum and plasma has been used to monitor the impact of the pre-analytical steps on the sample quality and stability in order to propose standard operating procedures (SOPs) for deposition in biobanks. We analyzed the quality of serum and plasma samples as a function of the elapsed time (t = 0-4 h) between blood collection and processing and of the time from processing to freezing (up to 24 h). The stability of the urine metabolic profile over time (up to 24 h) at various storage temperatures was monitored as a function of the different pre-analytical treatments like pre-storage centrifugation, filtration, and addition of the bacteriostatic preservative sodium azide. Appreciable changes in the profiles, reflecting changes in the concentration of a number of metabolites, were detected and discussed in terms of chemical and enzymatic reactions for both blood and urine samples. Appropriate procedures for blood derivatives collection and urine preservation/storage that allow maintaining as much as possible the original metabolic profile of the fresh samples emerge, and are proposed as SOPs for biobanking.

  16. Erythema after laser skin resurfacing.

    PubMed

    Ruiz-Esparza, J; Barba Gomez, J M; Gomez de la Torre, O L; David, L

    1998-01-01

    Erythema after laser skin resurfacing is seen by many as a necessary evil in order to get good results from the procedure. A critical review of widely accepted concepts may lead to diminishing the length of postoperative erythema in patients undergoing laser resurfacing. The authors report on two previously unrecognized factors in the causation of this problem.

  17. [The birth of metapsychology. On the current interpretation of "Entwurf einer Psychologie" (1895)].

    PubMed

    Schmidt-Hellerau, C

    1995-12-01

    The general attitude towards Entwurf einer Psychologie (1895) is to reckon it among Freud's pre-analytic writings, i.e. that part of his work later more or less disowned by the author. Schmidt-Hellerau challenges this assessment by Freud and many of his successors, demonstrating that the Entwurf can legitimately be regarded as a meta-theory resolving - or skirting- the old classification problem of whether psychoanalysis is a science or an art by connecting the hitherto dissociated spheres of soma and psyche and conceptualizing of physiological and psychological processes. See thus, the Entwurf reveals itself as a theoretical document of astonishing modernity and undiminished relevance in that it records Freud's ambitious attempt to overcome the mind-body schism and the divide between neurophysiology and psychology. And it is precisely this problem, the author contends, which Freud's later metapsychology--and the controversies it has aroused--revolves around.

  18. The incidence of wound complications related to negative pressure wound therapy power outage and interruption of treatment in orthopaedic trauma patients.

    PubMed

    Collinge, Cory; Reddix, Robert

    2011-02-01

    Negative pressure wound therapy (NPWT) using the Vacuum Assisted Closure system is an invaluable tool for use on patients with complex limb and soft tissue problems. Recently, the manufacturer (Kinetic Concepts, Inc, San Antonio, TX) made significant modifications to the NPWT platform, including computer software, battery, alarming systems, electric cord and plug apparatus, and others. Since these modifications, we have seen several cases in which the NPWT device has powered off resulting in an unrecognized interruption of therapy. We sought to evaluate the conditions and clinical effects, if any, to orthopaedic trauma patients who experienced an interruption of NPWT therapy when the device powers off. Retrospective study of consecutive patients. Two neighboring regional trauma centers. One hundred twenty-three consecutive orthopaedic trauma patients treated with NPWT by two orthopaedic trauma surgeons between May and November 2008. Patient/injury, treatment, and perioperative clinical outcomes data (with emphasis on wound complications such as infection, graft loss, and unscheduled surgery) were collected from medical records and wound care databases. Twelve patients (10%) had problems with the NPWT device powering off causing an unrecognized interruption of therapy. Eleven patients underwent early (less than 6 hours) wound débridement and reapplication of NPWT after detection, of which nine required unplanned surgery. Seven of the 12 patients recognized as having failed NPWT of this type ultimately experienced wound complications, including five deep infections and both patients being treated with an Integra graft (loss of graft). We have seen substantial problems in orthopaedic trauma patients treated with the NPWT, in which the device has powered off resulting in an unrecognized interruption of therapy. This has resulted in atypically unhealthy-appearing wounds, unplanned surgeries for débridement, and most importantly, an increased incidence of wound complications, including infection and graft loss (P < 0.05).

  19. Policy Alternatives for Post-Industrial America Suggested in the "Bell Curve": The Untold Story.

    ERIC Educational Resources Information Center

    Bauer, Norman J.

    The primary problem that Richard J. Herrnstein and Charles Murray address in their book, "The Bell Curve," is that an unrecognized societal migration has been emerging in American society since 1950. People with high IQs are rewarded socially and economically, while the rest of the population has remained stagnant. This paper describes…

  20. When, What, and How Much to Reward in Reinforcement Learning-Based Models of Cognition

    ERIC Educational Resources Information Center

    Janssen, Christian P.; Gray, Wayne D.

    2012-01-01

    Reinforcement learning approaches to cognitive modeling represent task acquisition as learning to choose the sequence of steps that accomplishes the task while maximizing a reward. However, an apparently unrecognized problem for modelers is choosing when, what, and how much to reward; that is, when (the moment: end of trial, subtask, or some other…

  1. Effects of pre-analytical variables on flow cytometric diagnosis of canine lymphoma: A retrospective study (2009-2015).

    PubMed

    Comazzi, S; Cozzi, M; Bernardi, S; Zanella, D R; Aresu, L; Stefanello, D; Marconato, L; Martini, V

    2018-02-01

    Flow cytometry (FC) is increasingly being used for immunophenotyping and staging of canine lymphoma. The aim of this retrospective study was to assess pre-analytical variables that might influence the diagnostic utility of FC of lymph node (LN) fine needle aspirate (FNA) specimens from dogs with lymphoproliferative diseases. The study included 987 cases with LN FNA specimens sent for immunophenotyping that were submitted to a diagnostic laboratory in Italy from 2009 to 2015. Cases were grouped into 'diagnostic' and 'non-diagnostic'. Pre-analytical factors analysed by univariate and multivariate analyses were animal-related factors (breed, age, sex, size), operator-related factors (year, season, shipping method, submitting veterinarian) and sample-related factors (type of sample material, cellular concentration, cytological smears, artefacts). The submitting veterinarian, sample material, sample cellularity and artefacts affected the likelihood of having a diagnostic sample. The availability of specimens from different sites and of cytological smears increased the odds of obtaining a diagnostic result. Major artefacts affecting diagnostic utility included poor cellularity and the presence of dead cells. Flow cytometry on LN FNA samples yielded conclusive results in more than 90% of cases with adequate sample quality and sampling conditions. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Pre-analytical and analytical factors influencing Alzheimer's disease cerebrospinal fluid biomarker variability.

    PubMed

    Fourier, Anthony; Portelius, Erik; Zetterberg, Henrik; Blennow, Kaj; Quadrio, Isabelle; Perret-Liaudet, Armand

    2015-09-20

    A panel of cerebrospinal fluid (CSF) biomarkers including total Tau (t-Tau), phosphorylated Tau protein at residue 181 (p-Tau) and β-amyloid peptides (Aβ42 and Aβ40), is frequently used as an aid in Alzheimer's disease (AD) diagnosis for young patients with cognitive impairment, for predicting prodromal AD in mild cognitive impairment (MCI) subjects, for AD discrimination in atypical clinical phenotypes and for inclusion/exclusion and stratification of patients in clinical trials. Due to variability in absolute levels between laboratories, there is no consensus on medical cut-off value for the CSF AD signature. Thus, for full implementation of this core AD biomarker panel in clinical routine, this issue has to be solved. Variability can be explained both by pre-analytical and analytical factors. For example, the plastic tubes used for CSF collection and storage, the lack of reference material and the variability of the analytical protocols were identified as important sources of variability. The aim of this review is to highlight these pre-analytical and analytical factors and describe efforts done to counteract them in order to establish cut-off values for core CSF AD biomarkers. This review will give the current state of recommendations. Copyright © 2015. Published by Elsevier B.V.

  3. Evaluation of quality indicators in a laboratory supporting tertiary cancer care facilities in India.

    PubMed

    Kumar, Savitha Anil; Jayanna, Prashanth; Prabhudesai, Shilpa; Kumar, Ajai

    2014-01-01

    To collect and tabulate errors and nonconformities in the preanalytical, analytical, and postanalytical process phases in a diagnostic clinical laboratory that supports a super-specialty cancer center in India, and identify areas of potential improvement in patient services. We collected data from our laboratory during a period of 24 months. Departments in the study included clinical biochemistry, hematology, clinical pathology, microbiology and serology, surgical pathology, and molecular pathology. We had initiated quality assessment based on international standards in our laboratory in 2010, with the aim of obtaining accreditation by national and international governing bodies. We followed the guidelines specified by International Organization for Standardization (ISO) 15189:2007 to identify noncompliant elements of our processes. Among a total of 144,030 specimens that our referral laboratory received during the 2-year period of our study, we uncovered an overall error rate for all 3 process phases of 1.23%; all of our error rates closely approximated the results from our peer institutions. Errors were most common in the preanalytical phase in both years of study; preanalytical- and postanalytical-phase errors constituted more than 90% of all errors. Further improvements are warranted in laboratory services and are contingent on adequate training and interdepartmental communication and cooperation. Copyright© by the American Society for Clinical Pathology (ASCP).

  4. Technical evaluation of the novel preanalytical module on instrumentation laboratory ACL TOP: advancing automation in hemostasis testing.

    PubMed

    Lippi, Giuseppe; Ippolito, Luigi; Favaloro, Emmanuel J

    2013-10-01

    Automation in hemostasis testing is entering an exciting and unprecedented phase. This study was planned to assess the performance of the new preanalytical module on the hemostasis testing system Instrumentation Laboratory ACL TOP. The evaluation included interference studies to define reliable thresholds for rejecting samples with significant concentrations of interfering substances; within-run imprecision studies of plasma indices on four different interference degrees for each index; comparison studies with reference measures of hemolysis index, bilirubin, and triglycerides on clinical chemistry analyzers; and calculation of turnaround time with and without automatic performance of preanalytical check. The upper limits for sample rejection according to our interference studies were 3.6 g/L for hemoglobin, 13.6 mg/dL for bilirubin, and 1454 mg/dL for triglycerides. We found optimal precision for all indices (0.6% to 3.1% at clinically relevant thresholds) and highly significant correlations with reference measures on clinical chemistry analyzers (from 0.985 to 0.998). The limited increase of turnaround time (i.e., +3% and +5% with or without cap-piercing), coupled with no adjunctive costs over performance of normal coagulation assays, contribute to make the automatic check of plasma indices on ACL TOP a reliable and practical approach for improving testing quality and safeguarding patient safety.

  5. Need for gender-specific pre-analytical testing: the dark side of the moon in laboratory testing.

    PubMed

    Franconi, Flavia; Rosano, Giuseppe; Campesi, Ilaria

    2015-01-20

    Many international organisations encourage studies in a sex-gender perspective. However, research with a gender perspective presents a high degree of complexity, and the inclusion of sex-gender variable in experiments presents many methodological questions, the majority of which are still neglected. Overcoming these issues is fundamental to avoid erroneous results. Here, pre-analytical aspects of the research, such as study design, choice of utilised specimens, sample collection and processing, animal models of diseases, and the observer's role, are discussed. Artefacts in this stage of research could affect the predictive value of all analyses. Furthermore, the standardisation of research subjects according to their lifestyles and, if female, to their life phase and menses or oestrous cycle, is urgent to harmonise research worldwide. A sex-gender-specific attention to pre-analytical aspects could produce a decrease in the time for translation from the bench to bedside. Furthermore, sex-gender-specific pre-clinical pharmacological testing will enable adequate assessment of pharmacokinetic and pharmacodynamic actions of drugs and will enable, where appropriate, an adequate gender-specific clinical development plan. Therefore, sex-gender-specific pre-clinical research will increase the gender equity of care and will produce more evidence-based medicine. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  6. Pre-analytical phase: The automated ProTube device supports quality assurance in the phlebotomy process.

    PubMed

    Piva, Elisa; Tosato, Francesca; Plebani, Mario

    2015-12-07

    Most errors in laboratory medicine occur in the pre-analytical phase of the total testing process. Phlebotomy, a crucial step in the pre-analytical phase influencing laboratory results and patient outcome, calls for quality assurance procedures and automation in order to prevent errors and ensure patient safety. We compared the performance of a new small, automated device, the ProTube Inpeco, designed for use in phlebotomy with a complete traceability of the process, with a centralized automated system, BC ROBO. ProTube was used for 15,010 patients undergoing phlebotomy with 48,776 tubes being labeled. The mean time and standard deviation (SD) for blood sampling was 3:03 (min:sec; SD ± 1:24) when using ProTube, against 5:40 (min:sec; SD ± 1:57) when using BC ROBO. The mean number of patients per hour managed at each phlebotomy point was 16 ± 3 with ProTube, and 10 ± 2 with BC ROBO. No tubes were labeled erroneously or incorrectly, even if process failure occurred in 2.8% of cases when ProTube was used. Thanks to its cutting edge technology, the ProTube has many advantages over BC ROBO, above all in verifying patient identity, and in allowing a reduction in both identification error and tube mislabeling.

  7. Analytical and pre-analytical performance characteristics of a novel cartridge-type blood gas analyzer for point-of-care and laboratory testing.

    PubMed

    Oyaert, Matthijs; Van Maerken, Tom; Bridts, Silke; Van Loon, Silvi; Laverge, Heleen; Stove, Veronique

    2018-03-01

    Point-of-care blood gas test results may benefit therapeutic decision making by their immediate impact on patient care. We evaluated the (pre-)analytical performance of a novel cartridge-type blood gas analyzer, the GEM Premier 5000 (Werfen), for the determination of pH, partial carbon dioxide pressure (pCO 2 ), partial oxygen pressure (pO 2 ), sodium (Na + ), potassium (K + ), chloride (Cl - ), ionized calcium ( i Ca 2+ ), glucose, lactate, and total hemoglobin (tHb). Total imprecision was estimated according to the CLSI EP5-A2 protocol. The estimated total error was calculated based on the mean of the range claimed by the manufacturer. Based on the CLSI EP9-A2 evaluation protocol, a method comparison with the Siemens RapidPoint 500 and Abbott i-STAT CG8+ was performed. Obtained data were compared against preset quality specifications. Interference of potential pre-analytical confounders on co-oximetry and electrolyte concentrations were studied. The analytical performance was acceptable for all parameters tested. Method comparison demonstrated good agreement to the RapidPoint 500 and i-STAT CG8+, except for some parameters (RapidPoint 500: pCO 2 , K + , lactate and tHb; i-STAT CG8+: pO 2 , Na + , i Ca 2+ and tHb) for which significant differences between analyzers were recorded. No interference of lipemia or methylene blue on CO-oximetry results was found. On the contrary, significant interference for benzalkonium and hemolysis on electrolyte measurements were found, for which the user is notified by an interferent specific flag. Identification of sample errors from pre-analytical sources, such as interferences and automatic corrective actions, along with the analytical performance, ease of use and low maintenance time of the instrument, makes the evaluated instrument a suitable blood gas analyzer for both POCT and laboratory use. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  8. Small and large vessel disease in persons with unrecognized compared to recognized myocardial infarction: The Tromsø Study 2007-2008.

    PubMed

    Øhrn, Andrea Milde; Schirmer, Henrik; von Hanno, Therese; Mathiesen, Ellisiv B; Arntzen, Kjell Arne; Bertelsen, Geir; Njølstad, Inger; Løchen, Maja-Lisa; Wilsgaard, Tom; Bairey Merz, C Noel; Lindekleiv, Haakon

    2018-02-15

    Unrecognized myocardial infarction (MI) is a frequent condition with unknown underlying reason. We hypothesized the lack of recognition of MI is related to pathophysiology, specifically differences in underlying small and large vessel disease. 6128 participants were examined with retinal photography, ultrasound of the carotid artery and a 12‑lead electrocardiography (ECG). Small vessel disease was defined as narrower retinal arterioles and/or wider retinal venules measured on retinal photographs. Large vessel disease was defined as carotid artery pathology. We defined unrecognized MI as ECG-evidence of MI without a clinically recognized event. We analyzed the cross-sectional relationship between MI recognition and markers of small and large vessel disease, adjusted for age and sex. Unrecognized MI was present in 502 (8.2%) and recognized MI in 326 (5.3%) of the 6128 participants. Compared to recognized MI, unrecognized MI was associated with small vessel disease indicated by narrower retinal arterioles (OR 1.66, 95% CI 1.05-2.62, highest vs. lowest quartile). Unrecognized MI was less associated with wider retinal venules (OR 0.55, 95% CI 0.35-0.87, lowest vs. highest quartile). Compared to recognized MI, unrecognized MI was less associated with large vessel disease indicated by presence of plaque in the carotid artery (OR for presence of carotid artery plaque in unrecognized MI 0.51, 95% CI 0.37-0.69). No significant sex interaction was present. Unrecognized MI was more associated with small vessel disease and less associated with large vessel disease compared to recognized MI. These findings suggest that the pathophysiology behind unrecognized and recognized MI may differ. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  9. Hematological reference values of healthy Malaysian population.

    PubMed

    Roshan, T M; Rosline, H; Ahmed, S A; Rapiaah, M; Wan Zaidah, A; Khattak, M N

    2009-10-01

    Health and disease can only be distinguished by accurate and reliable reference values of a particular laboratory test. It is now a proven fact that there is considerable variation in hematology reference intervals depending on the demographic and preanalytical variables. There are evidences that values provided by manufacturers do not have appropriate application for all populations. Moreover, reference ranges provided by different laboratory manuals and books also do not solve this problem. We are presenting here normal reference ranges of Malaysian population. These values were determined by using Sysmex XE-2100 and ACL 9000 hematology and coagulation analyzers. Results from this study showed that there were considerable differences in the reference values from manufacturers, western population or laboratory manuals compared with those from the local population.

  10. Partnerships and Collaborations in Promoting Health and Wellness in Minority Communities: Lessons Learned and Future Directions

    ERIC Educational Resources Information Center

    Bryant, Lawrence O.

    2014-01-01

    Oppression in its many forms is so ingrained in the fabric of the legal, social, economic, educational, political, and medical systems in America that it often goes unrecognized and unaddressed. The chapters in this volume explored the evasive problem of health and wellness for racial, ethnic, and sexual minorities within a framework of adult…

  11. Comorbidity of Asperger's syndrome and Bipolar disorder

    PubMed Central

    2008-01-01

    Background and objective Asperger's Syndrome (AS) is a pervasive developmental disorder that is sometimes unrecognized, especially in the adult psychiatric setting. On the other hand, in patients with an AS diagnosis, comorbid psychiatric disorders may be unrecognized in the juvenile setting. The aim of the paper is to show and discuss some troublesome and complex problems of the management of patients with AS and comorbid Bipolar Disorder (BD). Methods The paper describes three patients affected by AS and bipolar spectrum disorders. Results and conclusion Mood stabilizers and 2nd generation antipsychotics were effective in the treatment of these AS patients with comorbid BD, while the use of antidepressants was associated with worsening of the mood disorder. It is of importance to recognize both the psychiatric diagnoses in order to arrange an exhaustive therapeutic program and to define specific and realistic goals of treatment. PMID:19014623

  12. Equations of motion for the gravitational two-body problem

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whitney, C.K.

    1988-01-01

    This paper reinvestigates the well-known gravitational two-body problem, in light of new information concerning the electrodynamic version of the problem. The well-known Lienard-Wiechert potentials, and the fields derived from them, are suspected to be time-shifted, anticipating the true potentials and fields by the time required for signal propagation from the source to the observer. This time shift is significant because it implies field directions different to first order in v/c. In the gravitational problem, the resulting observer accelerations become correlated with retarded source positions, rather than with present, unretarded source positions as was previously believed. This means there exist previouslymore » unrecognized first-order effects in gravitational systems.« less

  13. Kantian epistemology as an alternative to heroic astronomy

    NASA Astrophysics Data System (ADS)

    McLaughlin, W. I.

    Theoretical and observational methods in astronomy have advanced to a point where certain of their outcomes are difficult to comprehend with the traditional categories of human knowledge. The philosophical discipline of epistemology, the theory of knowledge, is used here to address four current problems in observational astronomy, exobiology, cosmology, and quantum mechanics. The problems are united by an epistemological content which, when unrecognized, has resulted in some heroic solutions of an ad hoc nature. Immanuel Kant's critical philosophy is employed because his work is consistent with basic attitudes in present-day physics and biology.

  14. Typed Linear Chain Conditional Random Fields and Their Application to Intrusion Detection

    NASA Astrophysics Data System (ADS)

    Elfers, Carsten; Horstmann, Mirko; Sohr, Karsten; Herzog, Otthein

    Intrusion detection in computer networks faces the problem of a large number of both false alarms and unrecognized attacks. To improve the precision of detection, various machine learning techniques have been proposed. However, one critical issue is that the amount of reference data that contains serious intrusions is very sparse. In this paper we present an inference process with linear chain conditional random fields that aims to solve this problem by using domain knowledge about the alerts of different intrusion sensors represented in an ontology.

  15. Kantian epistemology as an alternative to heroic astronomy

    NASA Technical Reports Server (NTRS)

    Mclaughlin, W. I.

    1985-01-01

    Theoretical and observational methods in astronomy have advanced to a point where certain of their outcomes are difficult to comprehend with the traditional categories of human knowledge. The philosophical discipline of epistemology, the theory of knowledge, is used here to address four current problems in observational astronomy, exobiology, cosmology, and quantum mechanics. The problems are united by an epistemological content which, when unrecognized, has resulted in some heroic solutions of an ad hoc nature. Kant's critical philosophy is employed because his work is consistent with basic attitudes in present-day physics and biology.

  16. Maslow's Hierarchy of Needs and the individual with chronic vestibular dysfunction.

    PubMed

    Haybach, P J

    1994-01-01

    Individuals with chronic vestibular dysfunction may have unmet physiological or safety needs on a chronic basis. Their inability to fulfill the basic needs and progress to higher needs can lead to a patient population with many psychosocial problems. Very often such problems are ignored or unrecognized or are misdiagnosed, and treated inappropriately. This disruption in the individual's life can lead to an inability to progress as a human being. Nursing assessment and appropriate interventions should be developed to treat psychosocial problems in this patient population. The nursing profession should serve patients with vestibular dysfunction through direct care, teaching, counseling, support group facilitation, and research into appropriate interventions.

  17. Advancing haemostasis automation--successful implementation of robotic centrifugation and sample processing in a tertiary service hospital.

    PubMed

    Sédille-Mostafaie, Nazanin; Engler, Hanna; Lutz, Susanne; Korte, Wolfgang

    2013-06-01

    Laboratories today face increasing pressure to automate operations due to increasing workloads and the need to reduce expenditure. Few studies to date have focussed on the laboratory automation of preanalytical coagulation specimen processing. In the present study, we examined whether a clinical chemistry automation protocol meets the preanalytical requirements for the analyses of coagulation. During the implementation of laboratory automation, we began to operate a pre- and postanalytical automation system. The preanalytical unit processes blood specimens for chemistry, immunology and coagulation by automated specimen processing. As the production of platelet-poor plasma is highly dependent on optimal centrifugation, we examined specimen handling under different centrifugation conditions in order to produce optimal platelet deficient plasma specimens. To this end, manually processed models centrifuged at 1500 g for 5 and 20 min were compared to an automated centrifugation model at 3000 g for 7 min. For analytical assays that are performed frequently enough to be targets for full automation, Passing-Bablok regression analysis showed close agreement between different centrifugation methods, with a correlation coefficient between 0.98 and 0.99 and a bias between -5% and +6%. For seldom performed assays that do not mandate full automation, the Passing-Bablok regression analysis showed acceptable to poor agreement between different centrifugation methods. A full automation solution is suitable and can be recommended for frequent haemostasis testing.

  18. Sharps and high-pressure injection injuries in veterinary and animal workers.

    PubMed

    Robertson, Colin E; Ackerman, Nicola A; Burke, Francis D; Reilly, William J

    2016-02-01

    Needlestick and 'sharps' injuries among those working with animals are a significant, under-reported and often ill-understood problem. Many patients present initially to Emergency Departments, where their potential to cause local and systemic infections and injury, zoonoses, allergic or anaphylactic reactions and death may be unrecognized. Increased awareness of the possibility of adverse effects and the consequences of these specific injuries is essential.

  19. Pre-analytic evaluation of volumetric absorptive microsampling and integration in a mass spectrometry-based metabolomics workflow.

    PubMed

    Volani, Chiara; Caprioli, Giulia; Calderisi, Giovanni; Sigurdsson, Baldur B; Rainer, Johannes; Gentilini, Ivo; Hicks, Andrew A; Pramstaller, Peter P; Weiss, Guenter; Smarason, Sigurdur V; Paglia, Giuseppe

    2017-10-01

    Volumetric absorptive microsampling (VAMS) is a novel approach that allows single-drop (10 μL) blood collection. Integration of VAMS with mass spectrometry (MS)-based untargeted metabolomics is an attractive solution for both human and animal studies. However, to boost the use of VAMS in metabolomics, key pre-analytical questions need to be addressed. Therefore, in this work, we integrated VAMS in a MS-based untargeted metabolomics workflow and investigated pre-analytical strategies such as sample extraction procedures and metabolome stability at different storage conditions. We first evaluated the best extraction procedure for the polar metabolome and found that the highest number and amount of metabolites were recovered upon extraction with acetonitrile/water (70:30). In contrast, basic conditions (pH 9) resulted in divergent metabolite profiles mainly resulting from the extraction of intracellular metabolites originating from red blood cells. In addition, the prolonged storage of blood samples at room temperature caused significant changes in metabolome composition, but once the VAMS devices were stored at - 80 °C, the metabolome remained stable for up to 6 months. The time used for drying the sample did also affect the metabolome. In fact, some metabolites were rapidly degraded or accumulated in the sample during the first 48 h at room temperature, indicating that a longer drying step will significantly change the concentration in the sample. Graphical abstract Volumetric absorptive microsampling (VAMS) is a novel technology that allows single-drop blood collection and, in combination with mass spectrometry (MS)-based untargeted metabolomics, represents an attractive solution for both human and animal studies. In this work, we integrated VAMS in a MS-based untargeted metabolomics workflow and investigated pre-analytical strategies such as sample extraction procedures and metabolome stability at different storage conditions. The latter revealed that prolonged storage of blood samples at room temperature caused significant changes in metabolome composition, but if VAMS devices were stored at - 80 °C, the metabolome remained stable for up to 6 months.

  20. Pre-Analytical Components of Risk in Four Branches of Clinical Laboratory in Romania--Prospective Study.

    PubMed

    David, Remona E; Dobreanu, Minodora

    2016-01-01

    Development of quality measurement principles is a strategic point for each clinical laboratory. Preexamination process is the most critical and the most difficult to be managed. The aim of this study is to identify, quantify, and monitor the nonconformities of the pre-analytical process using quality indicators that can affect the patient's health safety in four different locations of a Romanian private clinical laboratory. The study group consisted of all the analysis requests received by the departments of biochemistry, hematology, and coagulation from January through March 2015. In order to collect the pre-analytical nonconformities, we created a "Risk Budget", using the entries from the "Evidence notebook--non-conform samples" from the above mentioned departments. The laboratory established the quality indicators by means of the risk management technique in order to identify and control the sources of errors, FMEA (Failure Modes and Effects Analyses), which had been implemented and monitored for its purposes and special needs. For the assessment of the control level over the processes, the results were transformed on the Six Sigma scale, using the Westgard calculation method and being obtained in this way the frequency with which an error may occur. (https://www.westgard. com/six-sigma-calculators.htm). The obtained results prove that the quantification and monitoring of the indicators can be a control instrument for the pre-analytic activities. The calculation of the Six Sigma value adds extra information to the study because it allows the detection of the processes which need improvement (Sigma value higher than 4 represents a well controlled process). The highest rates were observed for the hemolyzed and the lipemic samples, in the department of biochemistry and hemolyzed, insufficient sample volume, or clotted samples for the department of hematology and coagulation. Significant statistical differences between laboratories participating in the study have been recorded for these indicators. The elaborated study between the four branches of a Romanian private clinical laboratory was a challenge, and it helped in choosing strategic decisions regarding the improvement of the patient's health safety in the institution, corresponding to the accreditation requirements in accordance with ISO 15189:2013.

  1. 26 CFR 1.860A-0 - Outline of REMIC provisions.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... foreign persons. § 1.860C-2Determination of REMIC taxable income or net loss. (a) Treatment of gain or... gain or loss. (3) Basis of contributed assets allocated among interests. (i) In general. (ii...) Treatment of unrecognized gain or loss. (i) Unrecognized gain on regular interests. (ii) Unrecognized loss...

  2. 26 CFR 1.1092(b)-5T - Definitions (temporary).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... defined in sections 1092(d)(4) (B) and (C) respectively. (k) Section 1256 contract. The term section 1256... referred to in paragraph (n)(1) of this section. (o) Unrecognized gain. The term unrecognized gain means unrecognized gain as defined in section 1092(a)(3)(A). (p) Substantially identical. The term substantially...

  3. 26 CFR 1.1092(b)-5T - Definitions (temporary).

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... defined in sections 1092(d)(4) (B) and (C) respectively. (k) Section 1256 contract. The term section 1256... referred to in paragraph (n)(1) of this section. (o) Unrecognized gain. The term unrecognized gain means unrecognized gain as defined in section 1092(a)(3)(A). (p) Substantially identical. The term substantially...

  4. 26 CFR 1.1092(b)-5T - Definitions (temporary).

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... defined in sections 1092(d)(4) (B) and (C) respectively. (k) Section 1256 contract. The term section 1256... referred to in paragraph (n)(1) of this section. (o) Unrecognized gain. The term unrecognized gain means unrecognized gain as defined in section 1092(a)(3)(A). (p) Substantially identical. The term substantially...

  5. 26 CFR 1.1092(b)-5T - Definitions (temporary).

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... defined in sections 1092(d)(4) (B) and (C) respectively. (k) Section 1256 contract. The term section 1256... referred to in paragraph (n)(1) of this section. (o) Unrecognized gain. The term unrecognized gain means unrecognized gain as defined in section 1092(a)(3)(A). (p) Substantially identical. The term substantially...

  6. 26 CFR 1.1092(b)-5T - Definitions (temporary).

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... defined in sections 1092(d)(4) (B) and (C) respectively. (k) Section 1256 contract. The term section 1256... referred to in paragraph (n)(1) of this section. (o) Unrecognized gain. The term unrecognized gain means unrecognized gain as defined in section 1092(a)(3)(A). (p) Substantially identical. The term substantially...

  7. Standardizing in vitro diagnostics tasks in clinical trials: a call for action.

    PubMed

    Lippi, Giuseppe; Simundic, Ana-Maria; Rodriguez-Manas, Leocadio; Bossuyt, Patrick; Banfi, Giuseppe

    2016-05-01

    Translational research is defined as the process of applying ideas, insights and discoveries generated through basic scientific inquiry to treatment or prevention of human diseases. Although precise information is lacking, several lines of evidence attest that up to 95% early-phase studies may not translate into tangible outcomes for improving clinical management. Major theoretical hurdles exist in the translational process, but is it also undeniable that many studies may have failed for practical reasons, such as the use of inappropriate diagnostic testing for evaluating efficacy, effectiveness or safety of a given medical intervention, or poor quality in laboratory testing. This can generate biased test results and result in misconceptions during data interpretation, eventually leading to no clinical benefit, possible harm, and a waste of valuable resources. From a genuine economic perspective, it can be estimated that over 10 million euros of funding may be lost each year in clinical trials in the European Union due to preanalytical and analytical problems. These are mostly attributions to the heterogeneity of current guidelines and recommendations for the testing process, to the poor evidence base for basic pre-analytical, analytical and post-analytical requirements in clinical trials, and to the failure to thoughtfully integrate the perspectives of clinicians, patients, nurses and diagnostic companies in laboratory best practices. The most rational means for filling the gap between what we know and what we practice in clinical trials cannot discount the development of multidisciplinary teams including research scientists, clinicians, nurses, patients associations and representative of in vitro diagnostic (IVD) companies, who should actively interplay and collaborate with laboratory professionals to adapt and disseminate evidence-based recommendations about biospecimen collection and management into the research settings, from preclinical to phase III studies.

  8. Pre-analytical and analytical aspects affecting clinical reliability of plasma glucose results.

    PubMed

    Pasqualetti, Sara; Braga, Federica; Panteghini, Mauro

    2017-07-01

    The measurement of plasma glucose (PG) plays a central role in recognizing disturbances in carbohydrate metabolism, with established decision limits that are globally accepted. This requires that PG results are reliable and unequivocally valid no matter where they are obtained. To control the pre-analytical variability of PG and prevent in vitro glycolysis, the use of citrate as rapidly effective glycolysis inhibitor has been proposed. However, the commercial availability of several tubes with studies showing different performance has created confusion among users. Moreover, and more importantly, studies have shown that tubes promptly inhibiting glycolysis give PG results that are significantly higher than tubes containing sodium fluoride only, used in the majority of studies generating the current PG cut-points, with a different clinical classification of subjects. From the analytical point of view, to be equivalent among different measuring systems, PG results should be traceable to a recognized higher-order reference via the implementation of an unbroken metrological hierarchy. In doing this, it is important that manufacturers of measuring systems consider the uncertainty accumulated through the different steps of the selected traceability chain. In particular, PG results should fulfil analytical performance specifications defined to fit the intended clinical application. Since PG has tight homeostatic control, its biological variability may be used to define these limits. Alternatively, given the central diagnostic role of the analyte, an outcome model showing the impact of analytical performance of test on clinical classifications of subjects can be used. Using these specifications, performance assessment studies employing commutable control materials with values assigned by reference procedure have shown that the quality of PG measurements is often far from desirable and that problems are exacerbated using point-of-care devices. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  9. [Automation and organization of technological process of urinalysis].

    PubMed

    Kolenkin, S M; Kishkun, A A; Kol'chenko, O L

    2000-12-01

    Results of introduction into practice of a working model of industrial technology of laboratory studies and KONE Specific Supra and Miditron M devices are shown as exemplified by clinical analysis of the urine. This technology helps standardize all stages and operations, improves the efficiency of quality control of laboratory studies, rationally organizes the work at all stages of the process, creates a system for permanent improvement of the efficiency of investigations at the preanalytical, analytical, and postanalytical stages of technological process of laboratory studies. As a result of introduction of this technology into laboratory practice, violations of quality criteria of clinical urinalysis decreased from 15 to 8% at the preanalytical stage and from 6 to 3% at the analytical stage. Automation of the analysis decreased the need in reagents 3-fold and improved the productivity at the analytical stage 4-fold.

  10. Pre-analytical method for NMR-based grape metabolic fingerprinting and chemometrics.

    PubMed

    Ali, Kashif; Maltese, Federica; Fortes, Ana Margarida; Pais, Maria Salomé; Verpoorte, Robert; Choi, Young Hae

    2011-10-10

    Although metabolomics aims at profiling all the metabolites in organisms, data quality is quite dependent on the pre-analytical methods employed. In order to evaluate current methods, different pre-analytical methods were compared and used for the metabolic profiling of grapevine as a model plant. Five grape cultivars from Portugal in combination with chemometrics were analyzed in this study. A common extraction method with deuterated water and methanol was found effective in the case of amino acids, organic acids, and sugars. For secondary metabolites like phenolics, solid phase extraction with C-18 cartridges showed good results. Principal component analysis, in combination with NMR spectroscopy, was applied and showed clear distinction among the cultivars. Primary metabolites such as choline, sucrose, and leucine were found discriminating for 'Alvarinho', while elevated levels of alanine, valine, and acetate were found in 'Arinto' (white varieties). Among the red cultivars, higher signals for citrate and GABA in 'Touriga Nacional', succinate and fumarate in 'Aragonês', and malate, ascorbate, fructose and glucose in 'Trincadeira', were observed. Based on the phenolic profile, 'Arinto' was found with higher levels of phenolics as compared to 'Alvarinho'. 'Trincadeira' showed lowest phenolics content while higher levels of flavonoids and phenylpropanoids were found in 'Aragonês' and 'Touriga Nacional', respectively. It is shown that the metabolite composition of the extract is highly affected by the extraction procedure and this consideration has to be taken in account for metabolomics studies. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Hemolysis from a nurses' standpoint--survey from four Croatian hospitals.

    PubMed

    Dorotić, Adrijana; Antončić, Dragana; Biljak, Vanja Radišić; Nedić, Dara; Beletić, Andjelo

    2015-01-01

    Hemolysis can occur during sample collection, handling and transport. It is more frequent when the non-laboratory staff performs sampling. The aim of this study was to assess nurses' knowledge on the causes of hemolysis and consequential impact on the laboratory tests results. Additionally, the differences in knowledge, related to work experience, professional degree and previous education about hemolysis were explored. An anonymus survey, containing 11 questions on demographics, causes of hemolysis, its impact on biochemical parameters and nurses' attitude towards additional education in preanalytics, was conducted in four Croatian hospitals. The answers were compared by Chi-squared and Fischer exact test. In total, 562 survey results were collected. Majority of nurses declared familiarity with the term "hemolysis" (99.6%). There were 77% of correct answers regarding questions about the causes of hemolysis, but only 50% when it comes to questions about interference in biochemical tests. The percentage of correct answers about causes was significantly lower (P=0.029) among more experienced nurses, and higher (P=0.027) in those with higher professional degree, while influence of previous education was not significant. Also, higher percentage of correct answers about interferences was encountered in nurses with longer work experience (P=0.039). More than 70% of nurses declared that additional education about preanalytical factors would be beneficial. Croatian nurses are familiar with the definition of hemolysis, but a lack of knowledge about causes and influence on laboratory test results is evident. Nurses are eager to improve their knowledge in this field of preanalytical phase.

  12. Preanalytical requirements for flow cytometric evaluation of platelet activation: choice of anticoagulant.

    PubMed

    Mody, M; Lazarus, A H; Semple, J W; Freedman, J

    1999-06-01

    Accurate assessment of in vivo or in vitro platelet activation requires optimal preanalytical conditions to prevent artefactual in vitro activation of the platelets. The choice of anticoagulant is one of the critical preanalytical conditions as anticoagulants exert different effects on the activation of platelets ex vivo. We tested the effectiveness of Diatube-H (also known as CTAD; sodium citrate, theophylline, adenosine and dipyridamole) and citrate vacutainer tubes in preventing artefactual activation of platelets and preserving functional reserve. Platelet surface expression of the CD62P (reflecting alpha granule release), CD63 (reflecting lysosomal release) and modulation of normal platelet membrane glycoproteins CD41a and CD42b, were measured in whole blood and in isolated platelets immediately after collection and at 6, 24 and 48 h after venipuncture. Samples taken into Diatube-H showed less spontaneous platelet activation than did those taken into citrate. To measure in vitro platelet functional reserve, thrombin was added as agonist to blood stored for varying periods up to 48 h. Although Diatube-H suppressed in vitro platelet activation for up to 4 h, in samples kept for 6-24 h before thrombin addition, the inhibitory effect was lost and platelets responded fully to agonist activation. Hence, Diatube-H preserved platelets and allowed for measurement of in vivo platelet activation as well as thrombin-induced in vitro platelet activation after 6-24 h, in both whole blood and isolated platelets.

  13. Thyroglobulin assay in fluids from lymph node fine needle-aspiration washout: influence of pre-analytical conditions.

    PubMed

    Casson, Florence Boux de; Moal, Valérie; Gauchez, Anne-Sophie; Moineau, Marie-Pierre; Sault, Corinne; Schlageter, Marie-Hélène; Massart, Catherine

    2017-04-01

    The aim of this study was to evaluate the pre-analytical factors contributing to uncertainty in thyroglobulin measurement in fluids from fine-needle aspiration (FNA) washout of cervical lymph nodes. We studied pre-analytical stability, in different conditions, of 41 samples prepared with concentrated solutions of thyroglobulin (FNA washout or certified standard) diluted in physiological saline solution or buffer containing 6% albumin. In this buffer, over time, no changes in thyroglobulin concentrations were observed in all storage conditions tested. In albumin free saline solution, thyroglobulin recovery rates depended on initial sample concentrations and on modalities of their conservation (in conventional storage tubes, recovery mean was 56% after 3 hours-storage at room temperature and 19% after 24 hours-storage for concentrations ranged from 2 to 183 μg/L; recovery was 95%, after 3 hours or 24 hours-storage at room temperature, for a concentration of 5,656 μg/L). We show here that these results are due to non-specific adsorption of thyroglobulin in storage tubes, which depends on sample protein concentrations. We also show that possible contamination of fluids from FNA washout by plasma proteins do not always adequately prevent this adsorption. In conclusion, non-specific adsorption in storage tubes strongly contributes to uncertainty in thyroglobulin measurement in physiological saline solution. It is therefore recommended, for FNA washout, to use a buffer containing proteins provided by the laboratory.

  14. Pre-Analytical Considerations for Successful Next-Generation Sequencing (NGS): Challenges and Opportunities for Formalin-Fixed and Paraffin-Embedded Tumor Tissue (FFPE) Samples

    PubMed Central

    Arreaza, Gladys; Qiu, Ping; Pang, Ling; Albright, Andrew; Hong, Lewis Z.; Marton, Matthew J.; Levitan, Diane

    2016-01-01

    In cancer drug discovery, it is important to investigate the genetic determinants of response or resistance to cancer therapy as well as factors that contribute to adverse events in the course of clinical trials. Despite the emergence of new technologies and the ability to measure more diverse analytes (e.g., circulating tumor cell (CTC), circulating tumor DNA (ctDNA), etc.), tumor tissue is still the most common and reliable source for biomarker investigation. Because of its worldwide use and ability to preserve samples for many decades at ambient temperature, formalin-fixed, paraffin-embedded tumor tissue (FFPE) is likely to be the preferred choice for tissue preservation in clinical practice for the foreseeable future. Multiple analyses are routinely performed on the same FFPE samples (such as Immunohistochemistry (IHC), in situ hybridization, RNAseq, DNAseq, TILseq, Methyl-Seq, etc.). Thus, specimen prioritization and optimization of the isolation of analytes is critical to ensure successful completion of each assay. FFPE is notorious for producing suboptimal DNA quality and low DNA yield. However, commercial vendors tend to request higher DNA sample mass than what is actually required for downstream assays, which restricts the breadth of biomarker work that can be performed. We evaluated multiple genomics service laboratories to assess the current state of NGS pre-analytical processing of FFPE. Significant differences in pre-analytical capabilities were observed. Key aspects are highlighted and recommendations are made to improve the current practice in translational research. PMID:27657050

  15. Contamination of dried blood spots - an underestimated risk in newborn screening.

    PubMed

    Winter, Theresa; Lange, Anja; Hannemann, Anke; Nauck, Matthias; Müller, Cornelia

    2018-01-26

    Newborn screening (NBS) is an established screening procedure in many countries worldwide, aiming at the early detection of inborn errors of metabolism. For decades, dried blood spots have been the standard specimen for NBS. The procedure of blood collection is well described and standardized and includes many critical pre-analytical steps. We examined the impact of contamination of some anticipated common substances on NBS results obtained from dry spot samples. This possible pre-analytical source of uncertainty has been poorly examined in the past. Capillary blood was obtained from 15 adult volunteers and applied to 10 screening filter papers per volunteer. Nine filter papers were contaminated without visible trace. The contaminants were baby diaper rash cream, baby wet wipes, disinfectant, liquid infant formula, liquid infant formula hypoallergenic (HA), ultrasonic gel, breast milk, feces, and urine. The differences between control and contaminated samples were evaluated for 45 NBS quantities. We estimated if the contaminations might lead to false-positive NBS results. Eight of nine investigated contaminants significantly altered NBS analyte concentrations and potentially caused false-positive screening outcomes. A contamination with feces was most influential, affecting 24 of 45 tested analytes followed by liquid infant formula (HA) and urine, affecting 19 and 13 of 45 analytes, respectively. A contamination of filter paper samples can have a substantial effect on the NBS results. Our results underline the importance of good pre-analytical training to make the staff aware of the threat and ensure reliable screening results.

  16. Behavior problems in children at time of first recognized seizure and changes over the following 3 years.

    PubMed

    Austin, J K; Perkins, S M; Johnson, C S; Fastenau, P S; Byars, A W; deGrauw, T J; Dunn, D W

    2011-08-01

    The purposes of this 36-month study of children with first recognized seizures were: (1) to describe baseline differences in behavior problems between children with and without prior unrecognized seizures; (2) to identify differences over time in behavior problems between children with seizures and their healthy siblings; (3) to identify the proportions of children with seizures and healthy siblings who were consistently at risk for behavior problems for 36 months; and (4) to identify risk factors for behavior problems 36 months following the first recognized seizure. Risk factors explored included demographic (child age and gender, caregiver education), neuropsychological (IQ, processing speed), seizure (epileptic syndrome, use of antiepileptic drug, seizure recurrence), and family (family mastery, satisfaction with family relationships, parent response) variables. Participants were 300 children aged 6 through 14 years with a first recognized seizure and 196 healthy siblings. Data were collected from medical records, structured interviews, self-report questionnaires, and neuropsychological testing. Behavior problems were measured using the Child Behavior Checklist and the Teacher's Report Form. Data analyses included descriptive statistics and linear mixed models. Children with prior unrecognized seizures were at higher risk for behavior problems at baseline. As a group, children with seizures showed a steady reduction in behavior problems over time. Children with seizures were found to have significantly more behavior problems than their siblings over time, and significantly more children with seizures (11.3%) than siblings (4.6%) had consistent behavior problems over time. Key risk factors for child behavior problems based on both caregivers and teachers were: less caregiver education, slower initial processing speed, slowing of processing speed over the first 36 months, and a number of family variables including lower levels of family mastery or child satisfaction with family relationships, lower parent support of the child's autonomy, and lower parent confidence in their ability to discipline their child. Children with new-onset seizures who are otherwise developing normally have higher rates of behavior problems than their healthy siblings; however, behavior problems are not consistently in the at-risk range in most children during the first 3 years after seizure onset. When children show behavior problems, family variables that might be targeted include family mastery, parent support of child autonomy, and parents' confidence in their ability to handle their children's behavior.

  17. Teen Depression and Suicide, A SILENT CRISIS.

    PubMed

    Kroning, Maureen; Kroning, Kayla

    2016-01-01

    Adolescent depression is a serious problem affecting 10.7% of all teens and 29.9% of high school students; 17% of high school students have contemplated suicide. Yet, depression in teens is often unrecognized. This article relays the tragic death of a 17-year-old, along with symptoms of depression and suicide in adolescents; DSM-5 criteria for depression; treatments including protective factors, psychotherapy, and medications; and imparts interventions for addressing this huge but silent crisis.

  18. Alcohol use and policy formation: an evolving social problem.

    PubMed

    Levine, Amir

    2012-01-01

    This article explores the evolutionary course that the social problem of alcohol use has taken in the United States since the Colonial Era. This article utilizes a range of theoretical models to analyze the evolving nature of alcohol use from an unrecognized to a perceived social problem. The models used include critical constructionism (Heiner, 2002), top-down policy model (Dye, 2001) and Mauss'(1975) understanding of social problems and movements. These theoretical constructs exhibit the relative nature of alcohol use as a social problem in regards to a specific time, place, and social context as well as the powerful and influential role that social elites have in defining alcohol asa social problem. Studies regarding the development of alcohol policy formation are discussed to illuminate the different powers, constituents, and factors that play a role in alcohol policy formation.Finally, implications for future study are discussed [corrected].

  19. [Optimization of blood gas analysis in intensive care units : Reduction of preanalytical errors and improvement of workflow].

    PubMed

    Kieninger, M; Zech, N; Mulzer, Y; Bele, S; Seemann, M; Künzig, H; Schneiker, A; Gruber, M

    2015-05-01

    Point of care testing with blood gas analysis (BGA) is an important factor for intensive care medicine. Continuous efforts to optimize workflow, improve safety for the staff and avoid preanalytical mistakes are important and should reflect quality management standards. In a prospective observational study it was investigated whether the implementation of a new system for BGA using labeled syringes and automated processing of the specimens leads to improvements compared to the previously used procedure. In a 4-week test period the time until receiving the final results of the BGA with the standard method used in the clinical routine (control group) was compared to the results in a second 4-week test period using the new labeled syringes and automated processing of the specimens (intervention group). In addition, preanalytical mistakes with both systems were checked during routine daily use. Finally, it was investigated whether a delay of 10 min between taking and analyzing the blood samples alters the results of the BGA. Preanalytical errors were frequently observed in the control group where non-deaerated samples were recorded in 87.3 % but in the intervention group almost all samples (98.9 %) were correctly deaerated. Insufficient homogenization due to omission of manual pivoting was seen in 83.2 % in the control group and in 89.9 % in the intervention group; however, in the intervention group the samples were homogenized automatically during the further analytical process. Although a survey among the staff revealed a high acceptance of the new system and a subjective improvement of workflow, a measurable gain in time after conversion to the new procedure could not be seen. The mean time needed for a complete analysis process until receiving the final results was 244 s in the intervention group and 201 s in the control group. A 10-min delay between taking and analyzing the blood samples led to a significant and clinically relevant elevation of the values for partial pressure of oxygen (pO2) in both groups compared to the results when analyzing the samples immediately (118.4 vs. 148.6 mmHg in the control group and 115.3 vs. 123.7 mmHg in the intervention group). When using standard syringes the partial pressure of carbon dioxide (pCO2) was significantly lower (40.5 vs. 38.3 mmHg) whereas no alterations were seen when using the labeled syringes. The implementation of a new BGA system with labeled syringes and automated processing of the specimens was possible without any difficulties under daily clinical routine conditions in this 10-bed intensive care unit (ICU). A gain of time could not be measured but a reduction in preanalytical errors using the labeled syringes with automated processing was found. Delayed analysis of blood samples can lead to significant changes in pO2 and pCO2 depending on the type of syringe used.

  20. Spiking of serum specimens with exogenous reporter peptides for mass spectrometry based protease profiling as diagnostic tool.

    PubMed

    Findeisen, Peter; Peccerella, Teresa; Post, Stefan; Wenz, Frederik; Neumaier, Michael

    2008-04-01

    Serum is a difficult matrix for the identification of biomarkers by mass spectrometry (MS). This is due to high-abundance proteins and their complex processing by a multitude of endogenous proteases making rigorous standardisation difficult. Here, we have investigated the use of defined exogenous reporter peptides as substrates for disease-specific proteases with respect to improved standardisation and disease classification accuracy. A recombinant N-terminal fragment of the Adenomatous Polyposis Coli (APC) protein was digested with trypsin to yield a peptide mixture for subsequent Reporter Peptide Spiking (RPS) of serum. Different preanalytical handling of serum samples was simulated by storage of serum samples for up to 6 h at ambient temperature, followed by RPS, further incubation under standardised conditions and testing for stability of protease-generated MS profiles. To demonstrate the superior classification accuracy achieved by RPS, a pilot profiling experiment was performed using serum specimens from pancreatic cancer patients (n = 50) and healthy controls (n = 50). After RPS six different peak categories could be defined, two of which (categories C and D) are modulated by endogenous proteases. These latter are relevant for improved classification accuracy as shown by enhanced disease-specific classification from 78% to 87% in unspiked and spiked samples, respectively. Peaks of these categories presented with unchanged signal intensities regardless of preanalytical conditions. The use of RPS generally improved the signal intensities of protease-generated peptide peaks. RPS circumvents preanalytical variabilities and improves classification accuracies. Our approach will be helpful to introduce MS-based proteomic profiling into routine laboratory testing.

  1. Hemolysis from a nurses’ standpoint – survey from four Croatian hospitals

    PubMed Central

    Dorotić, Adrijana; Antončić, Dragana; Biljak, Vanja Radišić; Nedić, Dara; Beletić, Andjelo

    2015-01-01

    Introduction Hemolysis can occur during sample collection, handling and transport. It is more frequent when the non-laboratory staff performs sampling. The aim of this study was to assess nurses’ knowledge on the causes of hemolysis and consequential impact on the laboratory tests results. Additionally, the differences in knowledge, related to work experience, professional degree and previous education about hemolysis were explored. Materials and methods An anonymus survey, containing 11 questions on demographics, causes of hemolysis, its impact on biochemical parameters and nurses’ attitude towards additional education in preanalytics, was conducted in four Croatian hospitals. The answers were compared by Chi-squared and Fischer exact test. Results In total, 562 survey results were collected. Majority of nurses declared familiarity with the term “hemolysis” (99.6%). There were 77% of correct answers regarding questions about the causes of hemolysis, but only 50% when it comes to questions about interference in biochemical tests. The percentage of correct answers about causes was significantly lower (P = 0.029) among more experienced nurses, and higher (P = 0.027) in those with higher professional degree, while influence of previous education was not significant. Also, higher percentage of correct answers about interferences was encountered in nurses with longer work experience (P = 0.039). More than 70% of nurses declared that additional education about preanalytical factors would be beneficial. Conclusion Croatian nurses are familiar with the definition of hemolysis, but a lack of knowledge about causes and influence on laboratory test results is evident. Nurses are eager to improve their knowledge in this field of preanalytical phase. PMID:26525069

  2. A Six Sigma Trial For Reduction of Error Rates in Pathology Laboratory.

    PubMed

    Tosuner, Zeynep; Gücin, Zühal; Kiran, Tuğçe; Büyükpinarbaşili, Nur; Turna, Seval; Taşkiran, Olcay; Arici, Dilek Sema

    2016-01-01

    A major target of quality assurance is the minimization of error rates in order to enhance patient safety. Six Sigma is a method targeting zero error (3.4 errors per million events) used in industry. The five main principles of Six Sigma are defining, measuring, analysis, improvement and control. Using this methodology, the causes of errors can be examined and process improvement strategies can be identified. The aim of our study was to evaluate the utility of Six Sigma methodology in error reduction in our pathology laboratory. The errors encountered between April 2014 and April 2015 were recorded by the pathology personnel. Error follow-up forms were examined by the quality control supervisor, administrative supervisor and the head of the department. Using Six Sigma methodology, the rate of errors was measured monthly and the distribution of errors at the preanalytic, analytic and postanalytical phases was analysed. Improvement strategies were reclaimed in the monthly intradepartmental meetings and the control of the units with high error rates was provided. Fifty-six (52.4%) of 107 recorded errors in total were at the pre-analytic phase. Forty-five errors (42%) were recorded as analytical and 6 errors (5.6%) as post-analytical. Two of the 45 errors were major irrevocable errors. The error rate was 6.8 per million in the first half of the year and 1.3 per million in the second half, decreasing by 79.77%. The Six Sigma trial in our pathology laboratory provided the reduction of the error rates mainly in the pre-analytic and analytic phases.

  3. Looking for new biomarkers of skin wound vitality with a cytokine-based multiplex assay: preliminary study.

    PubMed

    Peyron, Pierre-Antoine; Baccino, Éric; Nagot, Nicolas; Lehmann, Sylvain; Delaby, Constance

    2017-02-01

    Determination of skin wound vitality is an important issue in forensic practice. No reliable biomarker currently exists. Quantification of inflammatory cytokines in injured skin with MSD ® technology is an innovative and promising approach. This preliminary study aims to develop a protocol for the preparation and the analysis of skin samples. Samples from ante mortem wounds, post mortem wounds, and intact skin ("control samples") were taken from corpses at the autopsy. After an optimization of the pre-analytical protocol had been performed in terms of skin homogeneisation and proteic extraction, the concentration of TNF-α was measured in each sample with the MSD ® approach. Then five other cytokines of interest (IL-1β, IL-6, IL-10, IL-12p70 and IFN-γ) were simultaneously quantified with a MSD ® multiplex assay. The optimal pre-analytical conditions consist in a proteic extraction from a 6 mm diameter skin sample, in a PBS buffer with triton 0,05%. Our results show the linearity and the reproductibility of the TNF-α quantification with MSD ® , and an inter- and intra-individual variability of the concentrations of proteins. The MSD ® multiplex assay is likely to detect differential skin concentrations for each cytokine of interest. This preliminary study was used to develop and optimize the pre-analytical and analytical conditions of the MSD ® method using injured and healthy skin samples, for the purpose of looking for and identifying the cytokine, or the set of cytokines, that may be biomarkers of skin wound vitality.

  4. Effects of fecal sampling on preanalytical and analytical phases in quantitative fecal immunochemical tests for hemoglobin.

    PubMed

    Rapi, Stefano; Berardi, Margherita; Cellai, Filippo; Ciattini, Samuele; Chelazzi, Laura; Ognibene, Agostino; Rubeca, Tiziana

    2017-07-24

    Information on preanalytical variability is mandatory to bring laboratories up to ISO 15189 requirements. Fecal sampling is greatly affected by lack of harmonization in laboratory medicine. The aims of this study were to obtain information on the devices used for fecal sampling and to explore the effect of different amounts of feces on the results from the fecal immunochemical test for hemoglobin (FIT-Hb). Four commercial sample collection devices for quantitative FIT-Hb measurements were investigated. The volume of interest (VOI) of the probes was measured from diameter and geometry. Quantitative measurements of the mass of feces were carried out by gravimetry. The effects of an increased amount of feces on the analytical environment were investigated measuring the Hb values with a single analytical method. VOI was 8.22, 7.1 and 9.44 mm3 for probes that collected a target of 10 mg of feces, and 3.08 mm3 for one probe that targeted 2 mg of feces. The ratio between recovered and target amounts of devices ranged from 56% to 121%. Different changes in the measured Hb values were observed, in adding increasing amounts of feces in commercial buffers. The amounts of collected materials are related to the design of probes. Three out 4 manufacturers declare the same target amount using different sampling volumes and obtaining different amounts of collected materials. The introduction of a standard probes to reduce preanalytical variability could be an useful step for fecal test harmonization and to fulfill the ISO 15189 requirements.

  5. Evaluation of pre-analytical conditions and comparison of the performance of several digital PCR assays for the detection of major EGFR mutations in circulating DNA from non-small cell lung cancers: the CIRCAN_0 study

    PubMed Central

    Garcia, Jessica; Dusserre, Eric; Cheynet, Valérie; Bringuier, Pierre Paul; Brengle-Pesce, Karen; Wozny, Anne-Sophie; Rodriguez-Lafrasse, Claire; Freyer, Gilles; Brevet, Marie; Payen, Léa; Couraud, Sébastien

    2017-01-01

    Non invasive somatic detection assays are suitable for repetitive tumor characterization or for detecting the appearance of somatic resistance during lung cancer. Molecular diagnosis based on circulating free DNA (cfDNA) offers the opportunity to track the genomic evolution of the tumor, and was chosen to assess the molecular profile of several EGFR alterations, including deletions in exon 19 (delEX19), the L858R substitution on exon 21 and the EGFR resistance mutation T790M on exon 20. Our study aimed at determining optimal pre-analytical conditions and EGFR mutation detection assays for analyzing cfDNA using the picoliter-droplet digital polymerase chain reaction (ddPCR) assay. Within the framework of the CIRCAN project set-up at the Lyon University Hospital, plasma samples were collected to establish a pre-analytical and analytical workflow of cfDNA analysis. We evaluated all of the steps from blood sampling to mutation detection output, including shipping conditions (4H versus 24H in EDTA tubes), the reproducibility of cfDNA extraction, the specificity/sensitivity of ddPCR (using external controls), and the comparison of different PCR assays for the detection of the three most important EGFR hotspots, which highlighted the increased sensitivity of our in-house primers/probes. Hence, we have described a new protocol facilitating the molecular detection of somatic mutations in cancer patients from liquid biopsies, improving their diagnosis and introducing a less traumatic monitoring system during tumor progression. PMID:29152135

  6. Sources of Pre-Analytical Variations in Yield of DNA Extracted from Blood Samples: Analysis of 50,000 DNA Samples in EPIC

    PubMed Central

    Caboux, Elodie; Lallemand, Christophe; Ferro, Gilles; Hémon, Bertrand; Mendy, Maimuna; Biessy, Carine; Sims, Matt; Wareham, Nick; Britten, Abigail; Boland, Anne; Hutchinson, Amy; Siddiq, Afshan; Vineis, Paolo; Riboli, Elio; Romieu, Isabelle; Rinaldi, Sabina; Gunter, Marc J.; Peeters, Petra H. M.; van der Schouw, Yvonne T.; Travis, Ruth; Bueno-de-Mesquita, H. Bas; Canzian, Federico; Sánchez, Maria-José; Skeie, Guri; Olsen, Karina Standahl; Lund, Eiliv; Bilbao, Roberto; Sala, Núria; Barricarte, Aurelio; Palli, Domenico; Navarro, Carmen; Panico, Salvatore; Redondo, Maria Luisa; Polidoro, Silvia; Dossus, Laure; Boutron-Ruault, Marie Christine; Clavel-Chapelon, Françoise; Trichopoulou, Antonia; Trichopoulos, Dimitrios; Lagiou, Pagona; Boeing, Heiner; Fisher, Eva; Tumino, Rosario; Agnoli, Claudia; Hainaut, Pierre

    2012-01-01

    The European Prospective Investigation into Cancer and nutrition (EPIC) is a long-term, multi-centric prospective study in Europe investigating the relationships between cancer and nutrition. This study has served as a basis for a number of Genome-Wide Association Studies (GWAS) and other types of genetic analyses. Over a period of 5 years, 52,256 EPIC DNA samples have been extracted using an automated DNA extraction platform. Here we have evaluated the pre-analytical factors affecting DNA yield, including anthropometric, epidemiological and technical factors such as center of subject recruitment, age, gender, body-mass index, disease case or control status, tobacco consumption, number of aliquots of buffy coat used for DNA extraction, extraction machine or procedure, DNA quantification method, degree of haemolysis and variations in the timing of sample processing. We show that the largest significant variations in DNA yield were observed with degree of haemolysis and with center of subject recruitment. Age, gender, body-mass index, cancer case or control status and tobacco consumption also significantly impacted DNA yield. Feedback from laboratories which have analyzed DNA with different SNP genotyping technologies demonstrate that the vast majority of samples (approximately 88%) performed adequately in different types of assays. To our knowledge this study is the largest to date to evaluate the sources of pre-analytical variations in DNA extracted from peripheral leucocytes. The results provide a strong evidence-based rationale for standardized recommendations on blood collection and processing protocols for large-scale genetic studies. PMID:22808065

  7. 42 CFR 493.1200 - Introduction.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... (that is, preanalytic, analytic, and postanalytic) as well as general laboratory systems. (b) The...) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS Quality System for Nonwaived Testing § 493.1200 Introduction. (a) Each laboratory that performs nonwaived testing must establish and maintain written policies...

  8. Preeclampsia: is it because of the asymptomatic, unrecognized renal scars caused by urinary tract infections in childhood that become symptomatic with pregnancy?

    PubMed

    Ozlü, Tülay; Alçelik, Aytekin; Calişkan, Billur; Dönmez, Melahat Emine

    2012-11-01

    Preeclampsia is an important disease of pregnancy whose exact etiology is still unknown despite continuing developments in medicine. Although most commonly it is believed to be caused by a defective placentation, in this paper, we hypothesize that the primary underlying problem in the development of preeclampsia can be in kidneys in a greater proportion of cases than it is believed today. The increased intravascular volume and the increased work load of kidneys together with the resulting glomerular hypertrophy may precipitate nephrotic syndrome, which in this case is called "preeclampsia" in a previously affected kidney. Urinary tract infections in childhood leaving silent, unrecognized small scars in the kidneys may be the underlying renal cause which disrupts its silence with an increased work load of kidneys prominently occurring after the midtrimester. The histopathologic finding in kidneys with renal scars after childhood urinary tract infections and in preeclampsia is focal segmental glomerulosclerosis in the majority of cases and this similarity strengthens our hypothesis. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. The Clinician and Forensic Medicine

    PubMed Central

    Root, Irving; Scott, Wayne

    1973-01-01

    Although it is an intrinsic part of all medical practice forensic medicine often is either unrecognized as such or is consciously or subconsciously evaded. The failure to apply some rather basic and simple forensic principles that only the physician is capable of doing may result in problems to the patient ranging from frustration to near catastrophe. For physicians who are reasonably well equipped to understand the legal system, the successful conclusion of a legal case, including, sometimes, an appearance in court, can be stimulating and interesting. PMID:4733272

  10. Core components of a comprehensive quality assurance program in anatomic pathology.

    PubMed

    Nakhleh, Raouf E

    2009-11-01

    In this article the core components of a comprehensive quality assurance and improvement plan are outlined. Quality anatomic pathology work comes with focus on accurate, timely, and complete reports. A commitment to continuous quality improvement and a systems approach with a persistent effort helps to achieve this end. Departments should have a quality assurance and improvement plan that includes a risk assessment of real and potential problems facing the laboratory. The plan should also list the individuals responsible for carrying out the program with adequate resources, a defined timetable, and annual assessment for progress and future directions. Quality assurance monitors should address regulatory requirements and be organized by laboratory division (surgical pathology, cytology, etc) as well as 5 segments (preanalytic, analytic, postanalytic phases of the test cycle, turn-around-time, and customer satisfaction). Quality assurance data can also be used to evaluate individual pathologists using multiple parameters with peer group comparison.

  11. The Benefits and Challenges of an Interfaced Electronic Health Record and Laboratory Information System: Effects on Laboratory Processes.

    PubMed

    Petrides, Athena K; Bixho, Ida; Goonan, Ellen M; Bates, David W; Shaykevich, Shimon; Lipsitz, Stuart R; Landman, Adam B; Tanasijevic, Milenko J; Melanson, Stacy E F

    2017-03-01

    - A recent government regulation incentivizes implementation of an electronic health record (EHR) with computerized order entry and structured results display. Many institutions have also chosen to interface their EHR with their laboratory information system (LIS). - To determine the impact of an interfaced EHR-LIS on laboratory processes. - We analyzed several different processes before and after implementation of an interfaced EHR-LIS: the turnaround time, the number of stat specimens received, venipunctures per patient per day, preanalytic errors in phlebotomy, the number of add-on tests using a new electronic process, and the number of wrong test codes ordered. Data were gathered through the LIS and/or EHR. - The turnaround time for potassium and hematocrit decreased significantly (P = .047 and P = .004, respectively). The number of stat orders also decreased significantly, from 40% to 7% for potassium and hematocrit, respectively (P < .001 for both). Even though the average number of inpatient venipunctures per day increased from 1.38 to 1.62 (P < .001), the average number of preanalytic errors per month decreased from 2.24 to 0.16 per 1000 specimens (P < .001). Overall there was a 16% increase in add-on tests. The number of wrong test codes ordered was high and it was challenging for providers to correctly order some common tests. - An interfaced EHR-LIS significantly improved within-laboratory turnaround time and decreased stat requests and preanalytic phlebotomy errors. Despite increasing the number of add-on requests, an electronic add-on process increased efficiency and improved provider satisfaction. Laboratories implementing an interfaced EHR-LIS should be cautious of its effects on test ordering and patient venipunctures per day.

  12. Standardization and optimization of fluorescence in situ hybridization (FISH) for HER-2 assessment in breast cancer: A single center experience.

    PubMed

    Bogdanovska-Todorovska, Magdalena; Petrushevska, Gordana; Janevska, Vesna; Spasevska, Liljana; Kostadinova-Kunovska, Slavica

    2018-05-20

    Accurate assessment of human epidermal growth factor receptor 2 (HER-2) is crucial in selecting patients for targeted therapy. Commonly used methods for HER-2 testing are immunohistochemistry (IHC) and fluorescence in situ hybridization (FISH). Here we presented the implementation, optimization and standardization of two FISH protocols using breast cancer samples and assessed the impact of pre-analytical and analytical factors on HER-2 testing. Formalin fixed paraffin embedded (FFPE) tissue samples from 70 breast cancer patients were tested for HER-2 using PathVysion™ HER-2 DNA Probe Kit and two different paraffin pretreatment kits, Vysis/Abbott Paraffin Pretreatment Reagent Kit (40 samples) and DAKO Histology FISH Accessory Kit (30 samples). The concordance between FISH and IHC results was determined. Pre-analytical and analytical factors (i.e., fixation, baking, digestion, and post-hybridization washing) affected the efficiency and quality of hybridization. The overall hybridization success in our study was 98.6% (69/70); the failure rate was 1.4%. The DAKO pretreatment kit was more time-efficient and resulted in more uniform signals that were easier to interpret, compared to the Vysis/Abbott kit. The overall concordance between IHC and FISH was 84.06%, kappa coefficient 0.5976 (p < 0.0001). The greatest discordance (82%) between IHC and FISH was observed in IHC 2+ group. A standardized FISH protocol for HER-2 assessment, with high hybridization efficiency, is necessary due to variability in tissue processing and individual tissue characteristics. Differences in the pre-analytical and analytical steps can affect the hybridization quality and efficiency. The use of DAKO pretreatment kit is time-saving and cost-effective.

  13. Using Lean-Six Sigma to reduce hemolysis in the emergency care center in a collaborative quality improvement project with the hospital laboratory.

    PubMed

    Damato, Charlotte; Rickard, Dana

    2015-03-01

    As part of a strategic quality improvement plan, laboratory management at Sarasota Memorial Health Care System (SMHCS) focused its efforts on improving preanalytical work flow and blood collection processes-both negatively affected by hemolyzed specimens. When hemolysis is detected in a blood specimen, blood may need to be re-collected, resulting in bottlenecks and rework all along the value stream. From July through December 2009, hemolysis averaged 9.8% in the Emergency Care Center (ECC) and 3.4% housewide. The goal was set to reduce hemolysis to 2%. The project team identified hemolysis as one of seven factors contributing to non-value-added activities and bottlenecks in blood collection and preanalytical processes. Observations and interviews helped to identify error-prone practices and process variation. To verify the root causes of hemolysis, the findings were compared against best practices. The team developed a housewide protocol, standardized collection processes, created competency-based training, and enhanced ECC hiring practices. During December 2010-March 2011, following initial housewide interventions and ECC self-sustaining solutions, ECC hemolysis decreased by 91%-from 9.8% (423 hemolyzed/4,295 collected) to 0.88% (58 hemolyzed/6,560 collected). Housewide hemolysis decreased by 59%-from 3.4% (2,046 hemolyzed/60,307 collected) to 1.39% (619 hemolyzed/44,528 collected). Since the project, hemolysis has continued to trend downward; the mean percentage has consistently been < .05% for the ECC and < 1% housewide. Lean-Six Sigma tools helped to pinpoint hemolysis as a key inefficiency in blood collection and preanalytical work flow. Although focused on the ECC, the project team standardized blood collection practices and instituted quality devices to achieve hemolysis reductions housewide.

  14. Dietary Supplement Polypharmacy: An Unrecognized Public Health Problem?

    PubMed Central

    Gryzlak, Brian M.; Zimmerman, M. Bridget; Wallace, Robert B.

    2010-01-01

    Excessive and inappropriate use of medications, or ‘polypharmacy’, has been recognized as a public health problem. In addition, there is growing use of dietary supplements in the United States; however, little is known about the patterns of supplement use. Recent reports in the literature of cases of excessive or inappropriate use of herbal dietary supplements leading to the term ‘polyherbacy’. The clinical vignettes described in this article highlight the need for further research on the nature and extent of multiple and inappropriate dietary supplement use or ‘dietary supplement polypharmacy’. Clinical interviewing and population surveys both address this issue in complementary ways, and provide a further understanding of dietary supplement use patterns. PMID:18955288

  15. 42 CFR 493.1445 - Standard; Laboratory director responsibilities.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... quality laboratory services for all aspects of test performance, which includes the preanalytic, analytic... result is found to be unacceptable or unsatisfactory; (5) Ensure that the quality control and quality assessment programs are established and maintained to assure the quality of laboratory services provided and...

  16. 42 CFR 493.17 - Test categorization.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., analytic or postanalytic phases of the testing. (2) Training and experience—(i) Score 1. (A) Minimal training is required for preanalytic, analytic and postanalytic phases of the testing process; and (B... necessary for analytic test performance. (3) Reagents and materials preparation—(i) Score 1. (A) Reagents...

  17. 42 CFR 493.17 - Test categorization.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., analytic or postanalytic phases of the testing. (2) Training and experience—(i) Score 1. (A) Minimal training is required for preanalytic, analytic and postanalytic phases of the testing process; and (B... necessary for analytic test performance. (3) Reagents and materials preparation—(i) Score 1. (A) Reagents...

  18. Summary of the ISEV workshop on extracellular vesicles as disease biomarkers, held in Birmingham, UK, during December 2017

    PubMed Central

    Carter, David R. F.; Cheng, Lesley; Compton, Carolyn; Daaboul, George; Devitt, Andrew; Falcon-Perez, Juan Manuel; Gardiner, Chris; Helmbrecht, Clemens; Hendrix, An; Hoffman, Andrew; Kalluri, Raghu; Kang, Ji Yoon; Lässer, Cecilia; Lawson, Charlotte; Lenassi, Metka; Levin, Carina; Llorente, Alicia; Martens-Uzunova, Elena S.; Möller, Andreas; Ochiya, Takahiro; Pink, Ryan C; Tahara, Hidetoshi; Wauben, Marca H. M.; Webber, Jason P.; Yin, Hang; Nieuwland, Rienk

    2018-01-01

    ABSTRACT This report summarises the presentations and activities of the ISEV Workshop on extracellular vesicle biomarkers held in Birmingham, UK during December 2017. Among the key messages was broad agreement about the importance of biospecimen science. Much greater attention needs to be paid towards the provenance of collected samples. The workshop also highlighted clear gaps in our knowledge about pre-analytical factors that alter extracellular vesicles (EVs). The future utility of certified standards for credentialing of instruments and software, to analyse EV and for tracking the influence of isolation steps on the structure and content of EVs were also discussed. Several example studies were presented, demonstrating the potential utility for EVs in disease diagnosis, prognosis, longitudinal serial testing and stratification of patients. The conclusion of the workshop was that more effort focused on pre-analytical issues and benchmarking of isolation methods is needed to strengthen collaborations and advance more effective biomarkers.

  19. Preanalytical considerations in detection of colorectal cancer in blood serum using Raman molecular imaging (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Treado, Patrick J.; Stewart, Shona D.; Smith, Aaron; Kirschner, Heather; Post, Christopher; Overholt, Bergein F.

    2016-03-01

    Colorectal cancer (CRC) is the third most common cancer in men and women in the United States. Raman Molecular Imaging (RMI) is an effective technique to evaluate human tissue, cells and bodily fluids, including blood serum for disease diagnosis. ChemImage Corporation, in collaboration with clinicians, has been engaged in development of an in vitro diagnostic Raman assay focused on CRC detection. The Raman Assay for Colorectal Cancer (RACC) exploits the high specificity of Raman imaging to distinguish diseased from normal dried blood serum droplets without additional reagents. Pilot Study results from testing of hundreds of biobank patient samples have demonstrated that RACC detects CRC with high sensitivity and specificity. However, expanded clinical trials, which are ongoing, are revealing a host of important preanalytical considerations associated with sample collection, sample storage and stability, sample shipping, sample preparation and sample interferents, which impact detection performance. Results from recent clinical studies will be presented.

  20. Reverse transcription-polymerase chain reaction molecular testing of cytology specimens: Pre-analytic and analytic factors.

    PubMed

    Bridge, Julia A

    2017-01-01

    The introduction of molecular testing into cytopathology laboratory practice has expanded the types of samples considered feasible for identifying genetic alterations that play an essential role in cancer diagnosis and treatment. Reverse transcription-polymerase chain reaction (RT-PCR), a sensitive and specific technical approach for amplifying a defined segment of RNA after it has been reverse-transcribed into its DNA complement, is commonly used in clinical practice for the identification of recurrent or tumor-specific fusion gene events. Real-time RT-PCR (quantitative RT-PCR), a technical variation, also permits the quantitation of products generated during each cycle of the polymerase chain reaction process. This review addresses qualitative and quantitative pre-analytic and analytic considerations of RT-PCR as they relate to various cytologic specimens. An understanding of these aspects of genetic testing is central to attaining optimal results in the face of the challenges that cytology specimens may present. Cancer Cytopathol 2017;125:11-19. © 2016 American Cancer Society. © 2016 American Cancer Society.

  1. Errors in clinical laboratories or errors in laboratory medicine?

    PubMed

    Plebani, Mario

    2006-01-01

    Laboratory testing is a highly complex process and, although laboratory services are relatively safe, they are not as safe as they could or should be. Clinical laboratories have long focused their attention on quality control methods and quality assessment programs dealing with analytical aspects of testing. However, a growing body of evidence accumulated in recent decades demonstrates that quality in clinical laboratories cannot be assured by merely focusing on purely analytical aspects. The more recent surveys on errors in laboratory medicine conclude that in the delivery of laboratory testing, mistakes occur more frequently before (pre-analytical) and after (post-analytical) the test has been performed. Most errors are due to pre-analytical factors (46-68.2% of total errors), while a high error rate (18.5-47% of total errors) has also been found in the post-analytical phase. Errors due to analytical problems have been significantly reduced over time, but there is evidence that, particularly for immunoassays, interference may have a serious impact on patients. A description of the most frequent and risky pre-, intra- and post-analytical errors and advice on practical steps for measuring and reducing the risk of errors is therefore given in the present paper. Many mistakes in the Total Testing Process are called "laboratory errors", although these may be due to poor communication, action taken by others involved in the testing process (e.g., physicians, nurses and phlebotomists), or poorly designed processes, all of which are beyond the laboratory's control. Likewise, there is evidence that laboratory information is only partially utilized. A recent document from the International Organization for Standardization (ISO) recommends a new, broader definition of the term "laboratory error" and a classification of errors according to different criteria. In a modern approach to total quality, centered on patients' needs and satisfaction, the risk of errors and mistakes in pre- and post-examination steps must be minimized to guarantee the total quality of laboratory services.

  2. Clinical Laboratory Practice Recommendations for the Use of Cardiac Troponin in Acute Coronary Syndrome: Expert Opinion from the Academy of the American Association for Clinical Chemistry and the Task Force on Clinical Applications of Cardiac Bio-Markers of the International Federation of Clinical Chemistry and Laboratory Medicine.

    PubMed

    Wu, Alan H B; Christenson, Robert H; Greene, Dina N; Jaffe, Allan S; Kavsak, Peter A; Ordonez-Llanos, Jordi; Apple, Fred S

    2018-04-01

    This document is an essential companion to the third iteration of the National Academy of Clinical Biochemistry [NACB, 8 now the American Association for Clinical Chemistry (AACC) Academy] Laboratory Medicine Practice Guidelines (LMPG) on cardiac markers. The expert consensus recommendations were drafted in collaboration with the International Federation of Clinical Chemistry and Laboratory Medicine Task Force on Clinical Applications of Bio-Markers (IFCC TF-CB). We determined that there is sufficient clinical guidance on the use of cardiac troponin (cTn) testing from clinical practice groups. Thus, in this expert consensus document, we focused on clinical laboratory practice recommendations for high-sensitivity (hs)-cTn assays. This document utilized the expert opinion class of evidence to focus on the following 10 topics: ( a ) quality control (QC) utilization, ( b ) validation of the lower reportable analytical limits, ( c ) units to be used in reporting measurable concentrations for patients and QC materials, ( d ) 99th percentile sex-specific upper reference limits to define the reference interval; ( e ) criteria required to define hs-cTn assays, ( f ) communication with clinicians and the laboratory's role in educating clinicians regarding the influence of preanalytic and analytic problems that can confound assay results, ( g ) studies on hs-cTn assays and how authors need to document preanalytical and analytical variables, ( h ) harmonizing and standardizing assay results and the role of commutable materials, ( i ) time to reporting of results from sample receipt and sample collection, and ( j ) changes in hs-cTn concentrations over time and the role of both analytical and biological variabilities in interpreting results of serial blood collections. © 2017 American Association for Clinical Chemistry.

  3. Prevalence and Significance of Unrecognized Lower Extremity Peripheral Arterial Disease in General Medicine Practice

    PubMed Central

    McGrae McDermott, Mary; Kerwin, Diana R; Liu, Kiang; Martin, Gary J; O'Brien, Erin; Kaplan, Heather; Greenland, Philip

    2001-01-01

    OBJECTIVE To determine the prevalence of unrecognized lower extremity peripheral arterial disease (PAD) among men and women aged 55 years and older in a general internal medicine (GIM) practice and to identify characteristics and functional performance associated with unrecognized PAD. DESIGN Cross-sectional. SETTING Academic medical center. PARTICIPANTS We identified 143 patients with known PAD from the noninvasive vascular laboratory, and 239 men and women aged 55 and older with no prior PAD history from a GIM practice. Group 1 consisted of patients with PAD consecutively identified from the noninvasive vascular laboratory (n = 143). Group 2 included GIM practice patients found to have an ankle brachial index less than 0.90, consistent with PAD (n = 34). Group 3 consisted of GIM practice patients without PAD (n = 205). MEASUREMENTS AND MAIN RESULTS Leg functioning was assessed with the 6-minute walk, 4-meter walking velocity, and Walking Impairment Questionnaire (WIQ). Of GIM practice patients, 14% had unrecognized PAD. Only 44% of patients in Group 2 had exertional leg symptoms. Distances achieved in the 6-minute walk were 1,130, 1,362, and 1,539 feet for Groups 1, 2, and 3, respectively, adjusting for age, gender, and race (P < .001). The degree of difficulty walking due to leg symptoms as reported on the WIQ was comparable between Groups 2 and 3 and significantly greater in Group 1 than Group 2. In multiple logistic regression analysis including Groups 2 and 3, current cigarette smoking was associated independently with unrecognized PAD (odds ratio [OR], 6.82; 95% confidence interval [95% CI], 1.55 to 29.93). Aspirin therapy was nearly independently associated with absence of PAD (OR, 0.37; 95% CI, 0.12 to 1.12). CONCLUSION Unrecognized PAD is common among men and women aged 55 years and older in GIM practice and is associated with impaired lower extremity functioning. Ankle brachial index screening may be necessary to diagnose unrecognized PAD in a GIM practice. PMID:11422635

  4. Cirrhosis is Under-recognized in Patients Subsequently Diagnosed with Hepatocellular Cancer

    PubMed Central

    Walker, Megan; El-Serag, Hashem B.; Sada, Yvonne; Mittal, Sahil; Ying, Jun; Duan, Zhigang; Richardson, Peter; Davila, Jessica A.; Kanwal, Fasiha

    2015-01-01

    Background Most clinical practice guidelines recommend screening for HCC in patients with cirrhosis. However, patients with compensated cirrhosis are often asymptomatic and may remain unrecognized for years. Aims To determine the extent to which cirrhosis is unrecognized in a US Veteran population with HCC and to evaluate the association between lack of cirrhosis recognition and stage of HCC at diagnosis. Methods We reviewed the electronic medical records of a random sample of HCC cases diagnosed in the national Veterans Affairs system between 2005 and 2011. We conducted multivariable analyses adjusting for patients’ demographics, comorbidity, etiology of underlying disease, and healthcare utilization including HCC surveillance. Results Of 1201 patients with HCC and cirrhosis, 24.6% had unrecognized cirrhosis prior to HCC diagnosis. Older patients (>65yr, odds ratio [OR] 2.32), African Americans (OR 1.93), patients with alcoholic or NAFLD liver disease (OR 1.69 and 4.77 respectively), HIV (OR 3.02), and fewer comorbidities (Deyo 0 vs. 3, OR 2.42) had significantly higher odds of having unrecognized cirrhosis than comparison groups. Furthermore, patients with unrecognized cirrhosis were 6.5 times more likely to have advanced stage HCC at diagnosis. The effect of cirrhosis recognition on HCC stage remained significant after adjusting for pre-specified covariates (OR 3.37). Conclusions In one fourth of patients, cirrhosis was unrecognized prior to HCC diagnosis, and this group was significantly more likely to have advanced stage HCC. These findings emphasize the importance of timely evaluation for cirrhosis in at-risk populations as a critical step to improving outcomes for HCC patients. PMID:26784271

  5. 42 CFR 493.1241 - Standard: Test request.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 5 2014-10-01 2014-10-01 false Standard: Test request. 493.1241 Section 493.1241 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS Quality System for Nonwaived Testing Preanalytic Systems § 493.1241 Standard: Test request...

  6. A short history, principles, and types of ELISA, and our laboratory experience with peptide/protein analyses using ELISA.

    PubMed

    Aydin, Suleyman

    2015-10-01

    Playing a critical role in the metabolic homeostasis of living systems, the circulating concentrations of peptides/proteins are influenced by a variety of patho-physiological events. These peptide/protein concentrations in biological fluids are measured using various methods, the most common of which is enzymatic immunoassay EIA/ELISA and which guide the clinicians in diagnosing and monitoring diseases that inflict biological systems. All the techniques where enzymes are employed to show antigen-antibody reactions are generally referred to as enzymatic immunoassay EIA/ELISA method. Since the basic principles of EIA and ELISA are the same. The main objective of this review is to present an overview of the historical journey that had led to the invention of EIA/ELISA, an indispensible method for medical and research laboratories, types of ELISA developed after its invention [direct (the first ELISA method invented), indirect, sandwich and competitive methods], problems encountered during peptide/protein analyses (pre-analytical, analytical and post-analytical), rules to be followed to prevent these problems, and our laboratory experience of more than 15 years. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Persistently high prevalence and unrecognized HIV infection among men who have sex with men in Baltimore: the BESURE Study

    PubMed Central

    German, Danielle; Sifakis, Frangiscos; Maulsby, Cathy; Towe, Vivian L.; Flynn, Colin P.; Latkin, Carl A.; Celentano, David D.; Hauck, Heather; Holtgrave, David R.

    2017-01-01

    Background Given high rates of HIV among Baltimore MSM, we examined characteristics associated with HIV prevalence and unrecognized HIV infection among Baltimore MSM at two time points. Methods Cross-sectional behavioral surveys and HIV testing in 2004–2005 and 2008 using venue-based sampling among adult Baltimore men at MSM-identified locations. MSM was defined as sex with a male partner in the past year. Bivariate and backwards stepwise regression identified characteristics associated with HIV and unrecognized infection. Findings HIV prevalence was 37.7% overall in 2004–2005 (n=645) and 37.5% in 2008 (n=448), 51.4% and 44.7% among Black MSM, and 12.9% and 18.3% among non-Hispanic White MSM. Compared to non-Hispanic White MSM, Black MSM were 4.0 times (95% C.I.: 2.3, 7.0) more likely to be HIV-positive in 2004–2005 and 2.5 times (95% C.I.: 1.5, 4.0) more likely in 2008. Prevalence of unrecognized HIV infection was 58.4% overall in 2004–2005 and 74.4% in 2008, 63.8% and 76.9% among Black MSM, and 15.4% and 47.4% among non-Hispanic White MSM. In adjusted models, unrecognized infection was significantly associated with minority race/ethnicity, younger age, and no prior year doctor visits in 2004–5 and with younger age and no prior year doctor visits in 2008. Conclusion High rates of HIV infection and substantial rates of unrecognized HIV infection among Baltimore MSM, particularly men of color and young men, require urgent public and private sector attention and increased prevention response. PMID:21297479

  8. Preanalytical Confounding Factors in the Analysis of Cerebrospinal Fluid Biomarkers for Alzheimer’s Disease: The Issue of Diurnal Variation

    PubMed Central

    Cicognola, Claudia; Chiasserini, Davide; Parnetti, Lucilla

    2015-01-01

    Given the growing use of cerebrospinal fluid (CSF) beta-amyloid (Aβ) and tau as biomarkers for early diagnosis of Alzheimer’s disease (AD), it is essential that the diagnostic procedures are standardized and the results comparable across different laboratories. Preanalytical factors are reported to be the cause of at least 50% of the total variability. Among them, diurnal variability is a key issue and may have an impact on the comparability of the values obtained. The available studies on this issue are not conclusive so far. Fluctuations of CSF biomarkers in young healthy volunteers have been previously reported, while subsequent studies have not confirmed those observations in older subjects, the ones most likely to receive this test. The observed differences in circadian rhythms need to be further assessed not only in classical CSF biomarkers but also in novel forthcoming biomarkers. In this review, the existing data on the issue of diurnal variations of CSF classical biomarkers for AD will be analyzed, also evaluating the available data on new possible biomarkers. PMID:26175714

  9. Deciphering Sources of Variability in Clinical Pathology.

    PubMed

    Tripathi, Niraj K; Everds, Nancy E; Schultze, A Eric; Irizarry, Armando R; Hall, Robert L; Provencher, Anne; Aulbach, Adam

    2017-01-01

    The objectives of this session were to explore causes of variability in clinical pathology data due to preanalytical and analytical variables as well as study design and other procedures that occur in toxicity testing studies. The presenters highlighted challenges associated with such variability in differentiating test article-related effects from the effects of experimental procedures and its impact on overall data interpretation. These presentations focused on preanalytical and analytical variables and study design-related factors and their influence on clinical pathology data, and the importance of various factors that influence data interpretation including statistical analysis and reference intervals. Overall, these presentations touched upon potential effect of many variables on clinical pathology parameters, including animal physiology, sample collection process, specimen handling and analysis, study design, and some discussion points on how to manage those variables to ensure accurate interpretation of clinical pathology data in toxicity studies. This article is a brief synopsis of presentations given in a session entitled "Deciphering Sources of Variability in Clinical Pathology-It's Not Just about the Numbers" that occurred at the 35th Annual Symposium of the Society of Toxicologic Pathology in San Diego, California.

  10. Interferences from blood collection tube components on clinical chemistry assays

    PubMed Central

    Bowen, Raffick A.R.; Remaley, Alan T.

    2014-01-01

    Improper design or use of blood collection devices can adversely affect the accuracy of laboratory test results. Vascular access devices, such as catheters and needles, exert shear forces during blood flow, which creates a predisposition to cell lysis. Components from blood collection tubes, such as stoppers, lubricants, surfactants, and separator gels, can leach into specimens and/or adsorb analytes from a specimen; special tube additives may also alter analyte stability. Because of these interactions with blood specimens, blood collection devices are a potential source of pre-analytical error in laboratory testing. Accurate laboratory testing requires an understanding of the complex interactions between collection devices and blood specimens. Manufacturers, vendors, and clinical laboratorians must consider the pre-analytical challenges in laboratory testing. Although other authors have described the effects of endogenous substances on clinical assay results, the effects/impact of blood collection tube additives and components have not been well systematically described or explained. This review aims to identify and describe blood collection tube additives and their components and the strategies used to minimize their effects on clinical chemistry assays. PMID:24627713

  11. Metabolic profiling of body fluids and multivariate data analysis.

    PubMed

    Trezzi, Jean-Pierre; Jäger, Christian; Galozzi, Sara; Barkovits, Katalin; Marcus, Katrin; Mollenhauer, Brit; Hiller, Karsten

    2017-01-01

    Metabolome analyses of body fluids are challenging due pre-analytical variations, such as pre-processing delay and temperature, and constant dynamical changes of biochemical processes within the samples. Therefore, proper sample handling starting from the time of collection up to the analysis is crucial to obtain high quality samples and reproducible results. A metabolomics analysis is divided into 4 main steps: 1) Sample collection, 2) Metabolite extraction, 3) Data acquisition and 4) Data analysis. Here, we describe a protocol for gas chromatography coupled to mass spectrometry (GC-MS) based metabolic analysis for biological matrices, especially body fluids. This protocol can be applied on blood serum/plasma, saliva and cerebrospinal fluid (CSF) samples of humans and other vertebrates. It covers sample collection, sample pre-processing, metabolite extraction, GC-MS measurement and guidelines for the subsequent data analysis. Advantages of this protocol include: •Robust and reproducible metabolomics results, taking into account pre-analytical variations that may occur during the sampling process•Small sample volume required•Rapid and cost-effective processing of biological samples•Logistic regression based determination of biomarker signatures for in-depth data analysis.

  12. Reproducibility studies for experimental epitope detection in macrophages (EDIM).

    PubMed

    Japink, Dennis; Nap, Marius; Sosef, Meindert N; Nelemans, Patty J; Coy, Johannes F; Beets, Geerard; von Meyenfeldt, Maarten F; Leers, Math P G

    2014-05-01

    We have recently described epitope detection in macrophages (EDIM) by flow cytometry. This is a promising tool for the diagnosis and follow-up of malignancies. However, biological and technical validation is warranted before clinical applicability can be explored. The pre-analytic and analytic phases were investigated. Five different aspects were assessed: blood sample stability, intra-individual variability in healthy persons, intra-assay variation, inter-assay variation and assay transferability. The post-analytic phase was already partly standardized and described in an earlier study. The outcomes in the pre-analytic phase showed that samples are stable for 24h after venipuncture. Biological variation over time was similar to that of serum tumor marker assays; each patient has a baseline value. Intra-assay variation showed good reproducibility, while inter-assay variation showed reproducibility similar to that of to established serum tumor marker assays. Furthermore, the assay showed excellent transferability between analyzers. Under optimal analytic conditions the EDIM method is technically stable, reproducible and transferable. Biological variation over time needs further assessment in future work. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Biospecimen Reporting for Improved Study Quality

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moore, Ph.D., Helen M.; Kelly, Ph.D., Andrea B.; Jewell, Ph.D., Scott D.

    Human biospecimens are subjected to collection, processing, and storage that can significantly alter their molecular composition and consistency. These biospecimen preanalytical factors, in turn, influence experimental outcomes and the ability to reproduce scientific results. Currently, the extent and type of information specific to the biospecimen preanalytical conditions reported in scientific publications and regulatory submissions varies widely. To improve the quality of research that uses human tissues, it is crucial that information on the handling of biospecimens be reported in a thorough, accurate, and standardized manner. The Biospecimen Reporting for Improved Study Quality (BRISQ) recommendations outlined herein are intended to applymore » to any study in which human biospecimens are used. The purpose of reporting these details is to supply others, from researchers to regulators, with more consistent and standardized information to better evaluate, interpret, compare, and reproduce the experimental results. The BRISQ guidelines are proposed as an important and timely resource tool to strengthen communication and publications on biospecimen-related research and to help reassure patient contributors and the advocacy community that their contributions are valued and respected.« less

  14. Platelet Function Tests: Preanalytical Variables, Clinical Utility, Advantages, and Disadvantages.

    PubMed

    Hvas, Anne-Mette; Grove, Erik Lerkevang

    2017-01-01

    Platelet function tests are mainly used in the diagnostic work-up of platelet disorders. During the last decade, the additional use of platelet function tests to evaluate the effect of antiplatelet therapy has also emerged in an attempt to identify patients with an increased risk of arterial thrombosis. Furthermore, platelet function tests are increasingly used to measure residual effect of antiplatelet therapy prior to surgery with the aim of reducing the risk of bleeding. To a limited extend, platelet function tests are also used to evaluate hyperaggregability as a potential marker of a prothrombotic state outside the setting of antiplatelet therapy. This multifaceted use of platelet function tests and the development of simpler point-of-care tests with narrower application have increased the use of platelet function testing and also facilitated the use of platelet function tests outside the highly specialized laboratories. The present chapter describes the preanalytical variables, which should be taken into account when planning platelet function testing. Also, the most widely used platelet function tests are introduced, and their clinical utility and their relative advantages and disadvantages are discussed.

  15. The impact of unrecognized autoimmune rheumatic diseases on the incidence of preeclampsia and fetal growth restriction: a longitudinal cohort study.

    PubMed

    Spinillo, Arsenio; Beneventi, Fausta; Locatelli, Elena; Ramoni, Vèronique; Caporali, Roberto; Alpini, Claudia; Albonico, Giulia; Cavagnoli, Chiara; Montecucco, Carlomaurizio

    2016-10-18

    The burden of pregnancy complications associated with well defined, already established systemic rheumatic diseases preexisting pregnancy such as rheumatoid arthritis, systemic lupus erythematosus or scleroderma is well known. Systemic rheumatic diseases are characterized by a long natural history with few symptoms, an undifferentiated picture or a remitting course making difficult a timely diagnosis. It has been suggested that screening measures for these diseases could be useful but the impact of unrecognized systemic rheumatic disorders on pregnancy outcome is unknown. The objective of the study was to evaluate the impact of previously unrecognized systemic autoimmune rheumatic on the incidence of preeclampsia and fetal growth restriction (FGR). A longitudinal cohort-study with enrolment during the first trimester of pregnancy of women attending routine antenatal care using a two-step approach with a self-reported questionnaire, autoantibody detection and clinical evaluation of antibody-positive subjects. The incidence of FGR and preeclampsia in subjects with newly diagnosed rheumatic diseases was compared to that of selected negative controls adjusting for potential confounders by logistic regression analysis. The prevalence of previously unrecognized systemic rheumatic diseases was 0.4 % for rheumatoid arthritis (19/5232), 0.25 % (13/5232) for systemic lupus erythematosus, 0.31 % (16/5232) for Sjögren's syndrome, 0.3 % for primary antiphospholipid syndrome (14/5232) and 0.11 % (6/5232) for other miscellaneous diseases. Undifferentiated connective tissue disease was diagnosed in an additional 131 subjects (2.5 %). The incidence of either FGR or preeclampsia was 6.1 % (36/594) among controls and 25.3 % (50/198) in subjects with unrecognized rheumatic diseases (excess incidence = 3.9 % (95 % CI = 2.6-9.6) or 34 % (95 % CI = 22-44) of all cases of FGR/preeclampsia). The incidence of small for gestational age infant (SGA) was higher among subjects with unrecognized rheumatic diseases (41/198 as compared to 46/594; adjOdds Ratio = 3.1, 95 % CI =1.96-4.95) than in controls. The excess incidence associated with unrecognized rheumatic diseases was 2.7 % (95 % CI = 1.5-4) or 25 % (95 % CI = 12.8-34.8) of all SGA cases. Unrecognized autoimmune systemic rheumatic disorders are associated with a significant proportion of preeclampsia and fetal growth failure, suggesting that their role in the etiology of adverse pregnancy outcome is probably undervalued.

  16. Quantitative assessment of effect of preanalytic cold ischemic time on protein expression in breast cancer tissues.

    PubMed

    Neumeister, Veronique M; Anagnostou, Valsamo; Siddiqui, Summar; England, Allison Michal; Zarrella, Elizabeth R; Vassilakopoulou, Maria; Parisi, Fabio; Kluger, Yuval; Hicks, David G; Rimm, David L

    2012-12-05

    Companion diagnostic tests can depend on accurate measurement of protein expression in tissues. Preanalytic variables, especially cold ischemic time (time from tissue removal to fixation in formalin) can affect the measurement and may cause false-negative results. We examined 23 proteins, including four commonly used breast cancer biomarker proteins, to quantify their sensitivity to cold ischemia in breast cancer tissues. A series of 93 breast cancer specimens with known time-to-fixation represented in a tissue microarray and a second series of 25 matched pairs of core needle biopsies and breast cancer resections were used to evaluate changes in antigenicity as a function of cold ischemic time. Estrogen receptor (ER), progesterone receptor (PgR), HER2 or Ki67, and 19 other antigens were tested. Each antigen was measured using the AQUA method of quantitative immunofluorescence on at least one series. All statistical tests were two-sided. We found no evidence for loss of antigenicity with time-to-fixation for ER, PgR, HER2, or Ki67 in a 4-hour time window. However, with a bootstrapping analysis, we observed a trend toward loss for ER and PgR, a statistically significant loss of antigenicity for phosphorylated tyrosine (P = .0048), and trends toward loss for other proteins. There was evidence of increased antigenicity in acetylated lysine, AKAP13 (P = .009), and HIF1A (P = .046), which are proteins known to be expressed in conditions of hypoxia. The loss of antigenicity for phosphorylated tyrosine and increase in expression of AKAP13, and HIF1A were confirmed in the biopsy/resection series. Key breast cancer biomarkers show no evidence of loss of antigenicity, although this dataset assesses the relatively short time beyond the 1-hour limit in recent guidelines. Other proteins show changes in antigenicity in both directions. Future studies that extend the time range and normalize for heterogeneity will provide more comprehensive information on preanalytic variation due to cold ischemic time.

  17. Does laboratory automation for the preanalytical phase improve data quality?

    PubMed

    Lima-Oliveira, Gabriel; Lippi, Giuseppe; Salvagno, Gian Luca; Danese, Elisa; Montagnana, Martina; Brocco, Giorgio; Voi, Monica; Picheth, Geraldo; Guidi, Gian Cesare

    2013-10-01

    Our aim was to evaluate whether automation for the preanalytical phase improves data quality. Blood from 100 volunteers was collected into two vacuum tubes. One sample from each volunteer was respectively assigned to (G1) traditional processing, starting with centrifugation at 1200 g for 10 min, and (G2) the MODULAR PRE-ANALYTICALS EVO-MPA system. The routine clinical chemistry tests were performed in duplicate on the same instrument Cobas 6000 module. G1 samples were uncapped manually and immediately placed into the instrument. G2 samples were directly fed from the MPA system to the instrument without further staff intervention. At the end, (1) the G1 samples were stored for 6 h at 4 °C as prescribed in our accredited laboratory and (2) the G2 samples were stored for 6 h in the MPA output buffer. Results from G1 and G2, before and after storage, were compared. Significant increases were observed in G1 compared with G2 samples as follows: (1) before storage for alkaline phosphatase (ALP), lactate dehydrogenase (LDH), phosphate (P), magnesium (MG), iron (FE), and hemolysis index and (2) after storage for total cholesterol (COL), triglycerides (TG), total protein (TP), albumin (ALB), blood urea nitrogen (BUN), creatinine (CRE), uric acid (UA), ALP, pancreatic amylase, aspartate aminotransferase (AST), alanine aminotransferase (ALT), g-glutamyltransferase (GGT), LDH, creatine kinase (CK), calcium (CA), FE, sodium (NA), potassium (K), and hemolysis index. Moreover, significant increases were observed in (3) G1-after versus G1-before storage samples for COL, high-density lipoprotein cholesterol, TG, TP, ALB, BUN, CRE, UA, AST, ALT, GGT, LDH, P, CA, MG, FE, NA, K, and hemolysis index and (4) G2-after versus G2-before storage only for BUN, AST, LDH, P, and CA. In conclusion, our results show that the MPA system improves the quality of laboratory testing.

  18. Evaluation of a model to improve collection of blood cultures in patients with sepsis in the emergency room.

    PubMed

    Mariani, B; Corbella, M; Seminari, E; Sacco, L; Cambieri, P; Capra Marzani, F; Martino, I F; Bressan, M A; Muzzi, A; Marena, C; Tinelli, C; Marone, P

    2018-02-01

    Sepsis begins outside of the hospital for nearly 80% of patients and the emergency room (ER) represents the first contact with the health care system. This study evaluates a project to improve collection of blood cultures (BCs) in patients with sepsis in the ER consisting of staff education and completion of the appropriate BC pre-analytical phase. A retrospective observational study performed to analyse the data on BC collection in the ER before and after a three-phase project. The first phase (1 January to 30 June 2015) before the intervention consisted of evaluation of data on BCs routinely collected in the ER. The second phase (1 July to 31 December 2015) was the intervention phase in which educational courses on sepsis recognition and on pre-analytical phase procedures (including direct incubation) were provided to ER staff. The third phase (1 January to 30 June 2016; after the intervention) again consisted of evaluation. Before the intervention, out of 24,738 admissions to the ER, 103 patients (0.4%) were identified as septic and had BCs drawn (359 BC bottles); 19 out of 103 patients (18.4%) had positive BCs. After the intervention, out of 24,702 admissions, 313 patients (1.3%) had BCs drawn (1,242 bottles); of these, 96 (30.7%) had positive BCs. Comparing the first and third periods, an increase in the percentage of patients with BCs collected (from 0.4% to 1.3% respectively, p < 0.0001) and an increase in the percentages of patients with true-positive BCs (from 0.08% to 0.39% of all patients evaluated respectively, p < 0.0001) were observed. The isolation of bacteria by BCs increased 3.25-fold after project implementation. These results can be principally ascribed to an improved awareness of sepsis in the staff associated with improved pre-analytical phase procedures in BC collection.

  19. Pre-analytical effects of blood sampling and handling in quantitative immunoassays for rheumatoid arthritis.

    PubMed

    Zhao, Xiaoyan; Qureshi, Ferhan; Eastman, P Scott; Manning, William C; Alexander, Claire; Robinson, William H; Hesterberg, Lyndal K

    2012-04-30

    Variability in pre-analytical blood sampling and handling can significantly impact results obtained in quantitative immunoassays. Understanding the impact of these variables is critical for accurate quantification and validation of biomarker measurements. Particularly, in the design and execution of large clinical trials, even small differences in sample processing and handling can have dramatic effects in analytical reliability, results interpretation, trial management and outcome. The effects of two common blood sampling methods (serum vs. plasma) and two widely-used serum handling methods (on the clot with ambient temperature shipping, "traditional", vs. centrifuged with cold chain shipping, "protocol") on protein and autoantibody concentrations were examined. Matched serum and plasma samples were collected from 32 rheumatoid arthritis (RA) patients representing a wide range of disease activity status. Additionally, a set of matched serum samples with two sample handling methods was collected. One tube was processed per manufacturer's instructions and shipped overnight on cold packs (protocol). The matched tube, without prior centrifugation, was simultaneously shipped overnight at ambient temperatures (traditional). Upon delivery, the traditional tube was centrifuged. All samples were subsequently aliquoted and frozen prior to analysis of protein and autoantibody biomarkers. Median correlation between paired serum and plasma across all autoantibody assays was 0.99 (0.98-1.00) with a median % difference of -3.3 (-7.5 to 6.0). In contrast, observed protein biomarker concentrations were significantly affected by sample types, with median correlation of 0.99 (0.33-1.00) and a median % difference of -10 (-55 to 23). When the two serum collection/handling methods were compared, the median correlation between paired samples for autoantibodies was 0.99 (0.91-1.00) with a median difference of 4%. In contrast, significant increases were observed in protein biomarker concentrations among certain biomarkers in samples processed with the 'traditional' method. Autoantibody quantification appears robust to both sample type (plasma vs. serum) and pre-analytical sample collection/handling methods (protocol vs. traditional). In contrast, for non-antibody protein biomarker concentrations, sample type had a significant impact; plasma samples generally exhibit decreased protein biomarker concentrations relative to serum. Similarly, sample handling significantly impacted the variability of protein biomarker concentrations. When biomarker concentrations are combined algorithmically into a single test score such as a multi-biomarker disease activity test for rheumatoid arthritis (MBDA), changes in protein biomarker concentrations may result in a bias of the score. These results illustrate the importance of characterizing pre-analytical methodology, sample type, sample processing and handling procedures for clinical testing in order to ensure test accuracy. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. [Stab injuries of the skull and brain].

    PubMed

    Ritter, C; Adebahr, G

    1986-01-01

    A few cases of skull and brain stab wounds are described and the clinicodiagnostic problems discussed. The injuries often remain unrecognized because the external wound often appears harmless, there are no neurological symptoms, or the clinical picture is interpreted as drunkenness, blunt injury or as another disease. The importance of a precise physical examination of the whole patient's head is pointed out. The refined methods used in modern radiodiagnostics of the skull are the most helpful in correctly recognizing these injuries; there are reports of patients with severe injuries who recovered when the correct diagnosis had been established.

  1. Longitudinal instability of the forearm.

    PubMed

    Phadnis, J; Watts, A C

    2016-10-01

    The Essex Lopresti lesion is a rare triad of injury to the radial head, interosseous membrane of the forearm and distal radio-ulnar joint, which results in longitudinal instability of the radius. If unrecognized this leads to chronic pain and disability which is difficult to salvage. Early recognition and appropriate treatment is therefore desirable to prevent long-term problems. The aim of this article is to review the pathoanatomy of longitudinal radius instability and use the existing literature and authors' experience to provide recommendations for recognition and treatment of acute and chronic forearm instability, including description of the author's technique for interosseous membrane reconstruction.

  2. An Unusual Cause of GI Bleeding in a Quadriplegic: Report of a Case and Review of the Literature

    PubMed Central

    Joseph, Raymond E.; Epsten, Robert; Kowlessar, O. Dhodanand

    1982-01-01

    The authors report a case of upper gastrointestinal hemorrhage in a quadriplegic. The cause was a Mallory-Weiss tear, a previously unrecognized problem in these patients. The incidence of bleeding in patients with spinal cord injury is as high as 25 percent in the few reported series. We feel that with the increased risk of gastrointestinal bleeding in the spinal cord patient and the accompanying significant mortality, early endoscopy is essential for accurate diagnosis since clues to the presence, etiology, and severity of the bleeding are often lacking. PMID:6981707

  3. Impact of Design Effects in Large-Scale District and State Assessments

    ERIC Educational Resources Information Center

    Phillips, Gary W.

    2015-01-01

    This article proposes that sampling design effects have potentially huge unrecognized impacts on the results reported by large-scale district and state assessments in the United States. When design effects are unrecognized and unaccounted for they lead to underestimating the sampling error in item and test statistics. Underestimating the sampling…

  4. Minimizing the influence of unconscious bias in evaluations: a practical guide.

    PubMed

    Goldyne, Adam J

    2007-01-01

    The forensic psychiatrist's efforts to strive for objectivity may be impaired by unrecognized unconscious biases. The author presents a framework for understanding such biases. He then offers a practical approach for individual forensic psychiatrists who want to identify and minimize the influence of previously unrecognized biases on their evaluations.

  5. Blood lipid measurements. Variations and practical utility.

    PubMed

    Cooper, G R; Myers, G L; Smith, S J; Schlant, R C

    1992-03-25

    To describe the magnitude and impact of the major biological and analytical sources of variation in serum lipid and lipoprotein levels on risk of coronary heart disease; to present a way to qualitatively estimate the total intraindividual variation; and to demonstrate how to determine the number of specimens required to estimate, with 95% confidence, the "true" underlying total cholesterol value in the serum of a patient. Representative references on each source of variation were selected from more than 300 reviewed publications, most published within the past 5 years, to document current findings and concepts. Most articles reviewed were in English. Studies on biological sources of variation were selected using the following criteria: representative of published findings, clear statement of either significant or insignificant results, and acquisition of clinical and laboratory data under standardized conditions. Representative results for special populations such as women and children are reported when results differ from those of adult men. References were selected based on acceptable experimental design and use of standardized laboratory lipid measurements. The lipid levels considered representative for a selected source of variation arose from quantitative measurements by a suitably standardized laboratory. Statistical analysis of data was examined to assure reliability. The proposed method of estimating the biological coefficient of variation must be considered to give qualitative results, because only two or three serial specimens are collected in most cases for the estimation. Concern has arisen about the magnitude, impact, and interpretation of preanalytical as well as analytical sources of variation on reported results of lipid measurements of an individual. Preanalytical sources of variation from behavioral, clinical, and sampling sources constitute about 60% of the total variation in a reported lipid measurement of an individual. A technique is presented to allow physicians to qualitatively estimate the intraindividual biological variation of a patient from the results of two or more specimens reported from a standardized laboratory and to determine whether additional specimens are needed to meet the National Cholesterol Education Program recommendation that the intraindividual serum total cholesterol coefficient of variation not exceed 5.0. A National Reference Method Network has been established to help solve analytical problems.

  6. 42 CFR 493.1773 - Standard: Basic inspection requirements for all laboratories issued a CLIA certificate and CLIA...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... issued a certificate of accreditation, must permit CMS or a CMS agent to conduct validation and complaint inspections. (b) General requirements. As part of the inspection process, CMS or a CMS agent may require the... testing process (preanalytic, analytic, and postanalytic). (4) Permit CMS or a CMS agent access to all...

  7. 42 CFR 493.1773 - Standard: Basic inspection requirements for all laboratories issued a CLIA certificate and CLIA...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... issued a certificate of accreditation, must permit CMS or a CMS agent to conduct validation and complaint inspections. (b) General requirements. As part of the inspection process, CMS or a CMS agent may require the... testing process (preanalytic, analytic, and postanalytic). (4) Permit CMS or a CMS agent access to all...

  8. 42 CFR 493.1773 - Standard: Basic inspection requirements for all laboratories issued a CLIA certificate and CLIA...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... issued a certificate of accreditation, must permit CMS or a CMS agent to conduct validation and complaint inspections. (b) General requirements. As part of the inspection process, CMS or a CMS agent may require the... testing process (preanalytic, analytic, and postanalytic). (4) Permit CMS or a CMS agent access to all...

  9. 42 CFR 493.1773 - Standard: Basic inspection requirements for all laboratories issued a CLIA certificate and CLIA...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... issued a certificate of accreditation, must permit CMS or a CMS agent to conduct validation and complaint inspections. (b) General requirements. As part of the inspection process, CMS or a CMS agent may require the... testing process (preanalytic, analytic, and postanalytic). (4) Permit CMS or a CMS agent access to all...

  10. 42 CFR 493.1773 - Standard: Basic inspection requirements for all laboratories issued a CLIA certificate and CLIA...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... issued a certificate of accreditation, must permit CMS or a CMS agent to conduct validation and complaint inspections. (b) General requirements. As part of the inspection process, CMS or a CMS agent may require the... testing process (preanalytic, analytic, and postanalytic). (4) Permit CMS or a CMS agent access to all...

  11. The focus on sample quality: Influence of colon tissue collection on reliability of qPCR data

    PubMed Central

    Korenkova, Vlasta; Slyskova, Jana; Novosadova, Vendula; Pizzamiglio, Sara; Langerova, Lucie; Bjorkman, Jens; Vycital, Ondrej; Liska, Vaclav; Levy, Miroslav; Veskrna, Karel; Vodicka, Pavel; Vodickova, Ludmila; Kubista, Mikael; Verderio, Paolo

    2016-01-01

    Successful molecular analyses of human solid tissues require intact biological material with well-preserved nucleic acids, proteins, and other cell structures. Pre-analytical handling, comprising of the collection of material at the operating theatre, is among the first critical steps that influence sample quality. The aim of this study was to compare the experimental outcomes obtained from samples collected and stored by the conventional means of snap freezing and by PAXgene Tissue System (Qiagen). These approaches were evaluated by measuring rRNA and mRNA integrity of the samples (RNA Quality Indicator and Differential Amplification Method) and by gene expression profiling. The collection procedures of the biological material were implemented in two hospitals during colon cancer surgery in order to identify the impact of the collection method on the experimental outcome. Our study shows that the pre-analytical sample handling has a significant effect on the quality of RNA and on the variability of qPCR data. PAXgene collection mode proved to be more easily implemented in the operating room and moreover the quality of RNA obtained from human colon tissues by this method is superior to the one obtained by snap freezing. PMID:27383461

  12. Croatian Society of Medical Biochemistry and Laboratory Medicine: national recommendations for venous blood sampling

    PubMed Central

    Nikolac, Nora; Šupak-Smolčić, Vesna; Šimundić, Ana-Maria; Ćelap, Ivana

    2013-01-01

    Phlebotomy is one of the most complex medical procedures in the diagnosis, management and treatment of patients in healthcare. Since laboratory test results are the basis for a large proportion (60–80%) of medical decisions, any error in the phlebotomy process could have serious consequences. In order to minimize the possibility of errors, phlebotomy procedures should be standardised, well-documented and written instructions should be available at every workstation. Croatia is one of the few European countries that have national guidelines for phlebotomy, besides the universally used CLSI (Clinical Laboratory Standards Institute) H3-A6 Procedures for the Collection of Diagnostic Blood Specimens by Venipuncture; approved Standard-Sixth Edition (CLSI, 2007) and WHO (World Health Organization) guidelines on drawing blood: best practices in phlebotomy (WHO, 2010). However, the growing body of evidence in importance of preanalytical phase management resulted in a need for evidence based revision and expansion of existing recommendations. The Croatian Society for Medical Biochemistry and Laboratory Medicine, Working Group for the Preanalytical Phase issued this recommendation. This document is based on the CLSI guideline H3-A6, with significant differences and additional information. PMID:24266294

  13. Recognizing and Reducing Analytical Errors and Sources of Variation in Clinical Pathology Data in Safety Assessment Studies.

    PubMed

    Schultze, A E; Irizarry, A R

    2017-02-01

    Veterinary clinical pathologists are well positioned via education and training to assist in investigations of unexpected results or increased variation in clinical pathology data. Errors in testing and unexpected variability in clinical pathology data are sometimes referred to as "laboratory errors." These alterations may occur in the preanalytical, analytical, or postanalytical phases of studies. Most of the errors or variability in clinical pathology data occur in the preanalytical or postanalytical phases. True analytical errors occur within the laboratory and are usually the result of operator or instrument error. Analytical errors are often ≤10% of all errors in diagnostic testing, and the frequency of these types of errors has decreased in the last decade. Analytical errors and increased data variability may result from instrument malfunctions, inability to follow proper procedures, undetected failures in quality control, sample misidentification, and/or test interference. This article (1) illustrates several different types of analytical errors and situations within laboratories that may result in increased variability in data, (2) provides recommendations regarding prevention of testing errors and techniques to control variation, and (3) provides a list of references that describe and advise how to deal with increased data variability.

  14. A Systematic Evaluation of Blood Serum and Plasma Pre-Analytics for Metabolomics Cohort Studies

    PubMed Central

    Jobard, Elodie; Trédan, Olivier; Postoly, Déborah; André, Fabrice; Martin, Anne-Laure; Elena-Herrmann, Bénédicte; Boyault, Sandrine

    2016-01-01

    The recent thriving development of biobanks and associated high-throughput phenotyping studies requires the elaboration of large-scale approaches for monitoring biological sample quality and compliance with standard protocols. We present a metabolomic investigation of human blood samples that delineates pitfalls and guidelines for the collection, storage and handling procedures for serum and plasma. A series of eight pre-processing technical parameters is systematically investigated along variable ranges commonly encountered across clinical studies. While metabolic fingerprints, as assessed by nuclear magnetic resonance, are not significantly affected by altered centrifugation parameters or delays between sample pre-processing (blood centrifugation) and storage, our metabolomic investigation highlights that both the delay and storage temperature between blood draw and centrifugation are the primary parameters impacting serum and plasma metabolic profiles. Storing the blood drawn at 4 °C is shown to be a reliable routine to confine variability associated with idle time prior to sample pre-processing. Based on their fine sensitivity to pre-analytical parameters and protocol variations, metabolic fingerprints could be exploited as valuable ways to determine compliance with standard procedures and quality assessment of blood samples within large multi-omic clinical and translational cohort studies. PMID:27929400

  15. Croatian Society of Medical Biochemistry and Laboratory Medicine: national recommendations for venous blood sampling.

    PubMed

    Nikolac, Nora; Supak-Smolcić, Vesna; Simundić, Ana-Maria; Celap, Ivana

    2013-01-01

    Phlebotomy is one of the most complex medical procedures in the diagnosis, management and treatment of patients in healthcare. Since laboratory test results are the basis for a large proportion (60-80%) of medical decisions, any error in the phlebotomy process could have serious consequences. In order to minimize the possibility of errors, phlebotomy procedures should be standardised, well-documented and written instructions should be available at every workstation. Croatia is one of the few European countries that have national guidelines for phlebotomy, besides the universally used CLSI (Clinical Laboratory Standards Institute) H3-A6 Procedures for the Collection of Diagnostic Blood Specimens by Venipuncture; approved Standard-Sixth Edition (CLSI, 2007) and WHO (World Health Organization) guidelines on drawing blood: best practices in phlebotomy (WHO, 2010). However, the growing body of evidence in importance of preanalytical phase management resulted in a need for evidence based revision and expansion of existing recommendations. The Croatian Society for Medical Biochemistry and Laboratory Medicine, Working Group for the Preanalytical Phase issued this recommendation. This document is based on the CLSI guideline H3-A6, with significant differences and additional information.

  16. MALDI-TOF MS identification of anaerobic bacteria: assessment of pre-analytical variables and specimen preparation techniques.

    PubMed

    Hsu, Yen-Michael S; Burnham, Carey-Ann D

    2014-06-01

    Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has emerged as a tool for identifying clinically relevant anaerobes. We evaluated the analytical performance characteristics of the Bruker Microflex with Biotyper 3.0 software system for identification of anaerobes and examined the impact of direct formic acid (FA) treatment and other pre-analytical factors on MALDI-TOF MS performance. A collection of 101 anaerobic bacteria were evaluated, including Clostridium spp., Propionibacterium spp., Fusobacterium spp., Bacteroides spp., and other anaerobic bacterial of clinical relevance. The results of our study indicate that an on-target extraction with 100% FA improves the rate of accurate identification without introducing misidentification (P<0.05). In addition, we modify the reporting cutoffs for the Biotyper "score" yielding acceptable identification. We found that a score of ≥1.700 can maximize the rate of identification. Of interest, MALDI-TOF MS can correctly identify anaerobes grown in suboptimal conditions, such as on selective culture media and following oxygen exposure. In conclusion, we report on a number of simple and cost-effective pre- and post-analytical modifications could enhance MALDI-TOF MS identification for anaerobic bacteria. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Management of thyroid cytological material, pre-analytical procedures and bio-banking.

    PubMed

    Bode-Lesniewska, Beata; Cochand-Priollet, Beatrix; Straccia, Patrizia; Fadda, Guido; Bongiovanni, Massimo

    2018-06-09

    Thyroid nodules are common and increasingly detected due to recent advances in imaging techniques. However, clinically relevant thyroid cancer is rare and the mortality from aggressive thyroid cancer remains constant. FNAC (Fine Needle Aspiration Cytology) is a standard method for diagnosing thyroid malignancy and the discrimination of malignant nodules from goiter. As the examined nodules on thyroid FNAC are often small incidental findings, it is important to maintain a low rate of undetermined diagnoses requiring further clinical work up or surgery. The most important factors determining the accuracy of the cytological diagnosis and suitability for biobanking of thyroid FNACs are the quality of the sample and availability of adequate tissue for auxiliary studies. This article analyses technical aspects (pre-analytics) of performing thyroid FNACs, including image guidance and rapid on slide evaluation (ROSE), sample collection methods (conventional slides, liquid based methods (LBC), cell blocks) and storage (bio-banking). The spectrum of the special studies (immunocytochemistry on direct slides or LBC, immunohistochemistry on cell blocks and molecular methods) required for improving the precision of the cytological diagnosis of the thyroid nodules is discussed. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  18. Mistakes in a stat laboratory: types and frequency.

    PubMed

    Plebani, M; Carraro, P

    1997-08-01

    Application of Total Quality Management concepts to laboratory testing requires that the total process, including preanalytical and postanalytical phases, be managed so as to reduce or, ideally, eliminate all defects within the process itself. Indeed a "mistake" can be defined as any defect during the entire testing process, from ordering tests to reporting results. We evaluated the frequency and types of mistakes found in the "stat" section of the Department of Laboratory Medicine of the University-Hospital of Padova by monitoring four different departments (internal medicine, nephrology, surgery, and intensive care unit) for 3 months. Among a total of 40490 analyses, we identified 189 laboratory mistakes, a relative frequency of 0.47%. The distribution of mistakes was: preanalytical 68.2%, analytical 13.3%, and postanalytical 18.5%. Most of the laboratory mistakes (74%) did not affect patients' outcome. However, in 37 patients (19%), laboratory mistakes were associated with further inappropriate investigations, thus resulting in an unjustifiable increase in costs. Moreover, in 12 patients (6.4%) laboratory mistakes were associated with inappropriate care or inappropriate modification of therapy. The promotion of quality control and continuous improvement of the total testing process, including pre- and postanalytical phases, seems to be a prerequisite for an effective laboratory service.

  19. GI-POP: a combinational annotation and genomic island prediction pipeline for ongoing microbial genome projects.

    PubMed

    Lee, Chi-Ching; Chen, Yi-Ping Phoebe; Yao, Tzu-Jung; Ma, Cheng-Yu; Lo, Wei-Cheng; Lyu, Ping-Chiang; Tang, Chuan Yi

    2013-04-10

    Sequencing of microbial genomes is important because of microbial-carrying antibiotic and pathogenetic activities. However, even with the help of new assembling software, finishing a whole genome is a time-consuming task. In most bacteria, pathogenetic or antibiotic genes are carried in genomic islands. Therefore, a quick genomic island (GI) prediction method is useful for ongoing sequencing genomes. In this work, we built a Web server called GI-POP (http://gipop.life.nthu.edu.tw) which integrates a sequence assembling tool, a functional annotation pipeline, and a high-performance GI predicting module, in a support vector machine (SVM)-based method called genomic island genomic profile scanning (GI-GPS). The draft genomes of the ongoing genome projects in contigs or scaffolds can be submitted to our Web server, and it provides the functional annotation and highly probable GI-predicting results. GI-POP is a comprehensive annotation Web server designed for ongoing genome project analysis. Researchers can perform annotation and obtain pre-analytic information include possible GIs, coding/non-coding sequences and functional analysis from their draft genomes. This pre-analytic system can provide useful information for finishing a genome sequencing project. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Pertussis in the Era of New Strains of Bordetella pertussis.

    PubMed

    Souder, Emily; Long, Sarah S

    2015-12-01

    Despite implementation of a successful vaccination program, pertussis remains a significant health problem. Although the incidence of pertussis in the United States is reduced by approximately 80% compared with incidence before the introduction of vaccination in the 1940s, deaths still occur and the unrecognized disease burden remains high, with 1 million Bordetella pertussis infections annually in the United States estimated by serologic surveys. Reasons for the resurgence and current prevalence of pertussis may be multifactorial and include waning vaccine-induced protection as well as lower vaccine effectiveness, failure to vaccinate, and changes in the organism itself. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Distant testing in laboratory hematology and flow cytometry--the Indian experience.

    PubMed

    Das Gupta, Amar

    2012-06-01

    Outsourcing or sending out of patients' samples to other laboratories for hematologic investigations is a common practice these days. Preanalytic variables that alter cellular parameters and levels of analytes in transit and on storage can significantly and adversely affect interpretation of test results in hematology. Awareness of these changes is necessary to avoid misinterpretation of results that in turn could influence medical management decisions.

  2. Preanalytic process linked to spuriously elevated HIV viral loads: improvement on an FDA-approved process.

    PubMed

    Procop, Gary W; Taege, Alan J; Starkey, Colleen; Tungsiripat, Marisa; Warner, Diane; Schold, Jesse D; Yen-Lieberman, Belinda

    2017-09-01

    The processing of specimens often occurs in a central processing area within laboratories. We demonstrated that plasma centrifuged in the central laboratory but allowed to remain within the primary tube following centrifugation was associated with spuriously elevated HIV viral loads compared with recentrifugation of the plasma just prior to testing. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Quality Control of RNA Preservation and Extraction from Paraffin-Embedded Tissue: Implications for RT-PCR and Microarray Analysis

    PubMed Central

    Pichler, Martin; Zatloukal, Kurt

    2013-01-01

    Analysis of RNA isolated from fixed and paraffin-embedded tissues is widely used in biomedical research and molecular pathological diagnostics. We have performed a comprehensive and systematic investigation of the impact of factors in the pre-analytical workflow, such as different fixatives, fixation time, RNA extraction method and storage of tissues in paraffin blocks, on several downstream reactions including complementary DNA (cDNA) synthesis, quantitative reverse transcription polymerase chain reaction (qRT-PCR) and microarray hybridization. We compared the effects of routine formalin fixation with the non-crosslinking, alcohol-based Tissue Tek Xpress Molecular Fixative (TTXMF, Sakura Finetek), and cryopreservation as gold standard for molecular analyses. Formalin fixation introduced major changes into microarray gene expression data and led to marked gene-to-gene variations in delta-ct values of qRT-PCR. We found that qRT-PCR efficiency and gene-to-gene variations were mainly attributed to differences in the efficiency of cDNA synthesis as the most sensitive step. These differences could not be reliably detected by quality assessment of total RNA isolated from formalin-fixed tissues by electrophoresis or spectrophotometry. Although RNA from TTXMF fixed samples was as fragmented as RNA from formalin fixed samples, much higher cDNA yield and lower ct-values were obtained in qRT-PCR underlining the negative impact of crosslinking by formalin. In order to better estimate the impact of pre-analytical procedures such as fixation on the reliability of downstream analysis, we applied a qRT-PCR-based assay using amplicons of different length and an assay measuring the efficiency of cDNA generation. Together these two assays allowed better quality assessment of RNA extracted from fixed and paraffin-embedded tissues and should be used to supplement quality scores derived from automated electrophoresis. A better standardization of the pre-analytical workflow, application of additional quality controls and detailed sample information would markedly improve the comparability and reliability of molecular studies based on formalin-fixed and paraffin-embedded tissue samples. PMID:23936242

  4. Quantitative Assessment of Effect of Preanalytic Cold Ischemic Time on Protein Expression in Breast Cancer Tissues

    PubMed Central

    2012-01-01

    Background Companion diagnostic tests can depend on accurate measurement of protein expression in tissues. Preanalytic variables, especially cold ischemic time (time from tissue removal to fixation in formalin) can affect the measurement and may cause false-negative results. We examined 23 proteins, including four commonly used breast cancer biomarker proteins, to quantify their sensitivity to cold ischemia in breast cancer tissues. Methods A series of 93 breast cancer specimens with known time-to-fixation represented in a tissue microarray and a second series of 25 matched pairs of core needle biopsies and breast cancer resections were used to evaluate changes in antigenicity as a function of cold ischemic time. Estrogen receptor (ER), progesterone receptor (PgR), HER2 or Ki67, and 19 other antigens were tested. Each antigen was measured using the AQUA method of quantitative immunofluorescence on at least one series. All statistical tests were two-sided. Results We found no evidence for loss of antigenicity with time-to-fixation for ER, PgR, HER2, or Ki67 in a 4-hour time window. However, with a bootstrapping analysis, we observed a trend toward loss for ER and PgR, a statistically significant loss of antigenicity for phosphorylated tyrosine (P = .0048), and trends toward loss for other proteins. There was evidence of increased antigenicity in acetylated lysine, AKAP13 (P = .009), and HIF1A (P = .046), which are proteins known to be expressed in conditions of hypoxia. The loss of antigenicity for phosphorylated tyrosine and increase in expression of AKAP13, and HIF1A were confirmed in the biopsy/resection series. Conclusions Key breast cancer biomarkers show no evidence of loss of antigenicity, although this dataset assesses the relatively short time beyond the 1-hour limit in recent guidelines. Other proteins show changes in antigenicity in both directions. Future studies that extend the time range and normalize for heterogeneity will provide more comprehensive information on preanalytic variation due to cold ischemic time. PMID:23090068

  5. Unrecognised ventriculitis/meningitis presenting as hydrocephalus in infancy.

    PubMed

    Udani, Vrajesh; Udani, Soonu; Merani, Rohan; Bavdekar, Manisha

    2003-09-01

    Infantile hydrocephalus due to unrecognized neonatal-onset meningitis/ventriculitis, was studied retrospectively using 1991-1998 chart review. Seventy two patients with hydrocephalus were reviewed. Thirteen infants had hydrocephalus associated with active meningitis/ventriculitis which had remained unrecognized. Active meningitis/ventriculitis was confirmed by the finding of an abnormal lumbar and ventricular CSF with or without positive culture. All had perinatal risk factors and 10/13 had been given antibiotics in the postnatal period. 6/13 infants appeared to be well. The most common presentation was increasing head size. All lumbar and ventricular CSFs were abnormal and 10/13 had positive cultures as well. Imaging revealed hydrocephalus in all. The infants were treated with antibiotics for a mean of 32.8 days before VP shunting. 7/11 were severely disabled. Unrecognized active meningitis/ventriculitis is an important cause of infantile hydrocephalus.

  6. Understanding and managing sleep disruption in children with fetal alcohol spectrum disorder.

    PubMed

    Hanlon-Dearman, Ana; Chen, Maida Lynn; Olson, Heather Carmichael

    2018-04-01

    Accumulating evidence has revealed high rates of sleep disruption among children with fetal alcohol spectrum disorder (FASD). Multiple animal and clinical studies have found a clear association between sleep problems and prenatal alcohol exposure, and recent research is beginning to characterize the types and extent of sleep disruption in FASD. Nevertheless, sleep disruption in children with FASD often goes unrecognized or is treated without referring to an evidence base. Children's disrupted sleep interferes with parental sleep and increases caregiver burden, which is of particular importance for families raising children with FASD, a group with very high levels of caregiving stress. The literature supporting an association between sleep problems and deficits in emotional, behavioral, and cognitive function in children is compelling, but needs further investigation in children with FASD. This paper will review the current state of knowledge on sleep in FASD and recommend a rational approach to sleep interventions for affected children and their families.

  7. Pseudomonas aeruginosa folliculitis acquired through use of a contaminated loofah sponge: an unrecognized potential public health problem.

    PubMed Central

    Bottone, E J; Perez, A A

    1993-01-01

    Pseudomonas aeruginosa folliculitis is a well-known entity that occurs among users of closed-cycle recreational water sources such as whirlpools, swimming pools, and hot tubs. In the absence of this epidemiologic link, isolated cases are difficult to diagnose. We encountered a patient who developed P. aeruginosa folliculitis subsequent to the use of a loofah sponge grossly contaminated with the same P. aeruginosa strain (serotype 10; pyocin type 1/a 4,b) that was recovered from her skin lesions. Furthermore, we demonstrated that sterile unused loofah sponges can serve as the sole growth-promoting substrate for P. aeruginosa. To obviate the potential public health problem of contaminated loofah sponges, it is strongly recommended that manufacturers append, and consumers adhere to, instructions as to the care of loofah sponges, which includes allowing the sponge to dry after use. Images PMID:8458939

  8. Alcoholism: diagnosis, prognosis, epidemiology, and burden of the disease.

    PubMed

    Beresford, Thomas P; Wongngamnit, Narin; Temple, Benjamin A

    2014-01-01

    To the clinician, alcoholism can appear as an amorphous entity that is confusing with respect to diagnosis, treatment prognosis, and the role of the health professional, despite its high incidence and associated morbidities and mortality when unrecognized or untreated. This chapter focuses on the clinical application of current knowledge, with the aim of being useful to the practitioner in working directly with patients for whom alcoholism may or may not be an already identified problem. It briefly reviews large-scale studies and then focuses on diagnosis and prognosis assessment and decision making. Also considered are current controversies in nomenclature and the chapter ends with an economic perspective with respect to healthcare and cost to society. As the introductory chapter, the goal is to provide a context of the scope of alcoholism and attendant problems for the rest of the chapters. © 2014 Elsevier B.V. All rights reserved.

  9. Deviation Management: Key Management Subsystem Driver of Knowledge-Based Continuous Improvement in the Henry Ford Production System.

    PubMed

    Zarbo, Richard J; Copeland, Jacqueline R; Varney, Ruan C

    2017-10-01

    To develop a business subsystem fulfilling International Organization for Standardization 15189 nonconformance management regulatory standard, facilitating employee engagement in problem identification and resolution to effect quality improvement and risk mitigation. From 2012 to 2016, the integrated laboratories of the Henry Ford Health System used a quality technical team to develop and improve a management subsystem designed to identify, track, trend, and summarize nonconformances based on frequency, risk, and root cause for elimination at the level of the work. Programmatic improvements and training resulted in markedly increased documentation culminating in 71,641 deviations in 2016 classified by a taxonomy of 281 defect types into preanalytic (74.8%), analytic (23.6%), and postanalytic (1.6%) testing phases. The top 10 deviations accounted for 55,843 (78%) of the total. Deviation management is a key subsystem of managers' standard work whereby knowledge of nonconformities assists in directing corrective actions and continuous improvements that promote consistent execution and higher levels of performance. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  10. CXCL5 is a Novel Mediator of Prostate Cancer Proliferation and Migration/Invasion

    DTIC Science & Technology

    2008-06-01

    such as Crohn disease , ulcerative colitis, and acute appendicitis, and by the exocrine tissue of the pancreas associated with chronic pancreatitis [9... disease , and may act as a previously unrecognized growth factor that promotes prostate cancer cell proliferation and migration/invasion. The major...proliferative prostatic disease , and may act as a previously unrecognized growth factor that promotes prostate cancer cell proliferation and migration

  11. Improving Histopathology Laboratory Productivity: Process Consultancy and A3 Problem Solving.

    PubMed

    Yörükoğlu, Kutsal; Özer, Erdener; Alptekin, Birsen; Öcal, Cem

    2017-01-01

    The ISO 17020 quality program has been run in our pathology laboratory for four years to establish an action plan for correction and prevention of identified errors. In this study, we aimed to evaluate the errors that we could not identify through ISO 17020 and/or solve by means of process consulting. Process consulting is carefully intervening in a group or team to help it to accomplish its goals. The A3 problem solving process was run under the leadership of a 'workflow, IT and consultancy manager'. An action team was established consisting of technical staff. A root cause analysis was applied for target conditions, and the 6-S method was implemented for solution proposals. Applicable proposals were activated and the results were rated by six-sigma analysis. Non-applicable proposals were reported to the laboratory administrator. A mislabelling error was the most complained issue triggering all pre-analytical errors. There were 21 non-value added steps grouped in 8 main targets on the fish bone graphic (transporting, recording, moving, individual, waiting, over-processing, over-transaction and errors). Unnecessary redundant requests, missing slides, archiving issues, redundant activities, and mislabelling errors were proposed to be solved by improving visibility and fixing spaghetti problems. Spatial re-organization, organizational marking, re-defining some operations, and labeling activities raised the six sigma score from 24% to 68% for all phases. Operational transactions such as implementation of a pathology laboratory system was suggested for long-term improvement. Laboratory management is a complex process. Quality control is an effective method to improve productivity. Systematic checking in a quality program may not always find and/or solve the problems. External observation may reveal crucial indicators about the system failures providing very simple solutions.

  12. Differences in metabolite profiles caused by pre-analytical blood processing procedures.

    PubMed

    Nishiumi, Shin; Suzuki, Makoto; Kobayashi, Takashi; Yoshida, Masaru

    2018-05-01

    Recently, the use of metabolomic analysis of human serum and plasma for biomarker discovery and disease diagnosis in clinical studies has been increasing. The feasibility of using a metabolite biomarker for disease diagnosis is strongly dependent on the metabolite's stability during pre-analytical blood processing procedures, such as serum or plasma sampling and sample storage prior to centrifugation. However, the influence of blood processing procedures on the stability of metabolites has not been fully characterized. In the present study, we compared the levels of metabolites in matched human serum and plasma samples using gas chromatography coupled with mass spectrometry and liquid chromatography coupled with mass spectrometry. In addition, we evaluated the changes in plasma metabolite levels induced by storage at room temperature or at a cold temperature prior to centrifugation. As a result, it was found that 76 metabolites exhibited significant differences between their serum and plasma levels. Furthermore, the pre-centrifugation storage conditions significantly affected the plasma levels of 45 metabolites. These results highlight the importance of blood processing procedures during metabolome analysis, which should be considered during biomarker discovery and the subsequent use of biomarkers for disease diagnosis. Copyright © 2017 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  13. Investigations of blood ammonia analysis: Test matrices, storage, and stability.

    PubMed

    Goldstein, Brittany N; Wesler, Jordan; Nowacki, Amy S; Reineks, Edmunds; Natowicz, Marvin R

    2017-06-01

    An assessment of blood ammonia concentration is common medical practice in the evaluation of an individual with an unexplained mental status change or coma. The determination of a blood ammonia level is most commonly done using a glutamate dehydrogenase (GLDH)-based assay, although there are many potential sources of artifact and the literature is inconsistent regarding key preanalytic issues. Using a GLDH-based assay, we first investigated matrix effects using three anticoagulants: heparin, EDTA and oxalate. Heparin-anticoagulated plasma was substantially less precise than EDTA- and oxalate-anticoagulated plasma. Oxalate-anticoagulated plasma showed a greater baseline of apparent ammonia than either heparin- or EDTA-derived plasma, presumably due to interferants. We then evaluated the stability of EDTA-anticoagulated plasma for assessment of ammonia when stored at 4°C,-14°C or -70°C. There was a linear increase of ammonia with storage at both 4°C and -14°C. Plasma kept at -70°C for up to three weeks showed no change in measured ammonia relative to the baseline determination. This work clarifies preanalytic conditions for which a precise determination of ammonia can be accomplished using a GLDH-based assay. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  14. Thawing as a critical pre-analytical step in the lipidomic profiling of plasma samples: New standardized protocol.

    PubMed

    Pizarro, Consuelo; Arenzana-Rámila, Irene; Pérez-del-Notario, Nuria; Pérez-Matute, Patricia; González-Sáiz, José María

    2016-03-17

    Lipid profiling is a promising tool for the discovery and subsequent identification of biomarkers associated with various diseases. However, data quality is quite dependent on the pre-analytical methods employed. To date, potential confounding factors that may affect lipid metabolite levels after the thawing of plasma for biomarker exploration studies have not been thoroughly evaluated. In this study, by means of experimental design methodology, we performed the first in-depth examination of the ways in which thawing conditions affect lipid metabolite levels. After the optimization stage, we concluded that temperature, sample volume and the thawing method were the determining factors that had to be exhaustively controlled in the thawing process to ensure the quality of biomarker discovery. Best thawing conditions were found to be: 4 °C, with 0.25 mL of human plasma and ultrasound (US) thawing. The new US proposed thawing method was quicker than the other methods we studied, allowed more features to be identified and increased the signal of the lipids. In view of its speed, efficiency and detectability, the US thawing method appears to be a simple, economical method for the thawing of plasma samples, which could easily be applied in clinical laboratories before lipid profiling studies. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Exploring phlebotomy technique as a pre-analytical factor in proteomic analyses by mass spectrometry.

    PubMed

    Penn, Andrew M; Lu, Linghong; Chambers, Andrew G; Balshaw, Robert F; Morrison, Jaclyn L; Votova, Kristine; Wood, Eileen; Smith, Derek S; Lesperance, Maria; del Zoppo, Gregory J; Borchers, Christoph H

    2015-12-01

    Multiple reaction monitoring mass spectrometry (MRM-MS) is an emerging technology for blood biomarker verification and validation; however, the results may be influenced by pre-analytical factors. This exploratory study was designed to determine if differences in phlebotomy techniques would significantly affect the abundance of plasma proteins in an upcoming biomarker development study. Blood was drawn from 10 healthy participants using four techniques: (1) a 20-gauge IV with vacutainer, (2) a 21-gauge direct vacutainer, (3) an 18-gauge butterfly with vacutainer, and (4) an 18-gauge butterfly with syringe draw. The abundances of a panel of 122 proteins (117 proteins, plus 5 matrix metalloproteinase (MMP) proteins) were targeted by LC/MRM-MS. In addition, complete blood count (CBC) data were also compared across the four techniques. Phlebotomy technique significantly affected 2 of the 11 CBC parameters (red blood cell count, p = 0.010; hemoglobin concentration, p = 0.035) and only 12 of the targeted 117 proteins (p < 0.05). Of the five MMP proteins, only MMP7 was detectable and its concentration was not significantly affected by different techniques. Overall, most proteins in this exploratory study were not significantly influenced by phlebotomy technique; however, a larger study with additional patients will be required for confirmation.

  16. Laboratory Automation and Intra-Laboratory Turnaround Time: Experience at the University Hospital Campus Bio-Medico of Rome.

    PubMed

    Angeletti, Silvia; De Cesaris, Marina; Hart, Jonathan George; Urbano, Michele; Vitali, Massimiliano Andrea; Fragliasso, Fulvio; Dicuonzo, Giordano

    2015-12-01

    Intra-laboratory turnaround time (TAT) is a key indicator of laboratory performance. Improving TAT is a complex task requiring staff education, equipment acquisition, and adequate TAT monitoring. The aim of the present study was to evaluate the intra-laboratory TAT after laboratory automation implementation (June 2013-June 2014) and to compare it to that in the preautomation period (July 2012-May 2013). Intra-laboratory TAT was evaluated both as the mean TAT registered and the percentage of outlier (OP) exams. The mean TAT was 36, 38, and 34 min during the study periods, respectively. These values respected the goal TAT established at 45 min. The OP, calculated at 45 min as well as at 60 min, decreased from 26 to 21 and from 11 to 5, respectively. From a focused analysis on blood count cell, troponin I, and prothrombin (PT) test, TAT improvement was more evident for tests requiring longer preanalytical process. The follow-up of TAT from June 2013 to June 2014 revealed the reduction of the mean TAT as well as of the OP exams after automation implementation and that automation more strongly affects the test in the preanalytical phase including centrifugation of the sample, such as troponin I and PT. © 2015 Society for Laboratory Automation and Screening.

  17. The mandate for a proper preservation in histopathological tissues.

    PubMed

    Comănescu, Maria; Arsene, D; Ardeleanu, Carmen; Bussolati, G

    2012-01-01

    A sequence of technically reproducible procedures is mandatory to guarantee a proper preservation of tissues and to build up the basis for sound diagnoses. However, while the goal of these procedures was, until recently, to assure only structural (histological and cytological) preservation, an appropriate preservation of antigenic properties and of nucleic acid integrity is now additionally requested, in order to permit pathologists to provide the biological information necessary for the adoption of personalized therapies. The present review analyses the sequence of technical steps open to critical variations. Passages such as dehydration, paraffin embedding, sectioning and staining are relatively well standardized and allow adoption of dedicated (automatic) apparatuses, while other pre-analytical steps, i.e. time and modalities of transfer of surgical specimens from the surgical theatre to the pathology laboratory (s.c. "ischemia time") and the type and length of fixation are not standardized and are a potential cause of discrepancies in diagnostic results. Our group is involved in European-funded projects tackling these problems with the concrete objective of implementing a model of effective tumors investigations by high performance genetic and molecular methodologies. The problem of the discrepant quality level of histopathological and cytological preparations involved five European countries and exploiting the potential of "virtual slide technology". Concrete issues, techniques and pitfalls, as well as proposed guidelines for processing the tissues are shown in this presentation.

  18. A single macrolichen constitutes hundreds of unrecognized species.

    PubMed

    Lücking, Robert; Dal-Forno, Manuela; Sikaroodi, Masoumeh; Gillevet, Patrick M; Bungartz, Frank; Moncada, Bibiana; Yánez-Ayabaca, Alba; Chaves, José Luis; Coca, Luis Fernando; Lawrey, James D

    2014-07-29

    The number of Fungi is estimated at between 1.5 and 3 million. Lichenized species are thought to make up a comparatively small portion of this figure, with unrecognized species richness hidden among little-studied, tropical microlichens. Recent findings, however, suggest that some macrolichens contain a large number of unrecognized taxa, increasing known species richness by an order of magnitude or more. Here we report the existence of at least 126 species in what until recently was believed to be a single taxon: the basidiolichen fungus Dictyonema glabratum, also known as Cora pavonia. Notably, these species are not cryptic but morphologically distinct. A predictive model suggests an even larger number, with more than 400 species. These results call into question species concepts in presumably well-known macrolichens and demonstrate the need for accurately documenting such species richness, given the importance of these lichens in endangered ecosystems such as paramos and the alarming potential for species losses throughout the tropics.

  19. Misleading hallucinations in unrecognized narcolepsy.

    PubMed

    Szucs, A; Janszky, J; Holló, A; Migléczi, G; Halász, P

    2003-10-01

    To describe psychosis-like hallucinatory states in unrecognized narcolepsy. Two patients with hypnagogic/hypnapompic hallucinations are presented. Both patients had realistic and complex - multi-modal and scenic-daytime sexual hallucinations leading, in the first case, to a legal procedure because of false accusation, and in the second, to serious workplace conflicts. Both patients were convinced of the reality of their hallucinatory experiences but later both were able to recognize their hallucinatory character. Clinical data, a multiple sleep latency test, polysomnography, and HLA typing revealed that both patients suffered from narcolepsy. We suggest that in unrecognized narcolepsy with daytime hypnagogic/hypnapompic hallucinations the diagnostic procedure may mistakenly incline towards delusional psychoses. Daytime realistic hypnagogic/hypnapompic hallucinations may also have forensic consequences and mislead legal evaluation. Useful clinical features in differentiating narcolepsy from psychoses are: the presence of other narcoleptic symptoms, features of hallucinations, and response to adequate medication.

  20. Anabolic steroid-induced cardiomyopathy underlying acute liver failure in a young bodybuilder.

    PubMed

    Bispo, Miguel; Valente, Ana; Maldonado, Rosário; Palma, Rui; Glória, Helena; Nóbrega, João; Alexandrino, Paula

    2009-06-21

    Heart failure may lead to subclinical circulatory disturbances and remain an unrecognized cause of ischemic liver injury. We present the case of a previously healthy 40-year-old bodybuilder, referred to our Intensive-Care Unit of Hepatology for treatment of severe acute liver failure, with the suspicion of toxic hepatitis associated with anabolic steroid abuse. Despite the absence of symptoms and signs of congestive heart failure at admission, an anabolic steroid-induced dilated cardiomyopathy with a large thrombus in both ventricles was found to be the underlying cause of the liver injury. Treatment for the initially unrecognized heart failure rapidly restored liver function to normal. To our knowledge, this is the first reported case of severe acute liver failure due to an unrecognized anabolic steroid-induced cardiomyopathy. Awareness of this unique presentation will allow for prompt treatment of this potentially fatal cause of liver failure.

  1. Role of training activities for the reduction of pre-analytical errors in laboratory samples from primary care.

    PubMed

    Romero, Adolfo; Cobos, Andrés; Gómez, Juan; Muñoz, Manuel

    2012-01-18

    The presence of pre-analytical errors (PE) is a usual contingency in laboratories. The incidence may increase where it is difficult to control that period, as it is the case with samples sent from primary care (PC) to clinical reference laboratory. Detection of a large number of PE in PC samples in our Institution led to the development and implementation of preventive strategies. The first of these has been the realization of a cycle of educational sessions for PC nurses, followed by the evaluation of their impact on PE number. The incidence of PE was assessed in two periods, before (October-November 2007) and after (October-November, 2009) the implementation of educational sessions. Eleven PC centers in the urban area and 17 in the rural area participated. In the urban area, samples were withdrawn by any PC nurse; in the rural area, samples were obtained by the patient's reference nurse. The types of analyzed PE included missed sample (MS), hemolyzed sample (HS), coagulated sample (CS), incorrect sample (ISV) and others (OPE), such as lipemic or icteric serum or plasma. In the former period, we received 52,669 blood samples and 18,852 urine samples, detecting 3885 (7.5%) and 1567 (8.3%) PEs, respectively. After the educational intervention, there were 52,659 and 19,048 samples with 5057 (9.6%) and 1.256 (6.5%) PEs, respectively (p<0.001). According to the type of PE, the incidents compared before and after compared incidences were: MS, 4.8% vs. 3.8%, p<0.001; HS, 1.97% vs. 3.9%, p<0.001; CS, 0.54% vs. 0.25%, p<0.001; ISV, 0.15% vs. 0.19% p=0.08; and OPE, 0.3% vs. 0.42%, p<0.001. Surprisingly the PE incidence increased after the educational intervention, although it should be noted that it was primarily due to the increase of HS, as the other EP incidence decreased (MS and CS) or remained unchanged (ISV). This seems to indicate the need for a comprehensive approach to reduce the incidence of errors in the pre-analytical period, as one stage interventions do not seem to be effective enough. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. Technical performance of lactate biosensors and a test-strip device during labour.

    PubMed

    Luttkus, A K; Fotopoulou, C; Sehouli, J; Stupin, J; Dudenhausen, J W

    2010-04-01

    Lactate in fetal blood has a high diagnostic power to detect fetal compromise due to hypoxia, as lactate allows an estimation of duration and intensity of metabolic acidemia. Biosensor technology allows an instantaneous diagnosis of fetal compromise in the delivery room. The goal of the current investigation is to define the preanalytical and analytical biases of this technology under routine conditions in a labour ward in comparison to test-strip technology, which allows measurement of lactate alone. Three lactate biosensors (RapidLab 865, Siemens Medical Solutions Diagnostics, Bad Nauheim, Germany; Radiometer ABL625 and ABL 700, Radiometer Copenhagen, Denmark) and one test-strip device (Lactate Pro, Oxford Instruments, UK) were evaluated regarding precision in serial and repetitive measurements in over 1350 samples of fetal whole blood. The coefficient of variation (CV) and the standard deviation (SD) were calculated. The average value of all three biosensors was defined as an artificial reference value (refval). Blood tonometry was performed in order to test the quality of respiratory parameters and to simulate conditions of fetal hypoxia (pO (2): 10 and 20 mmHg). The precision of serial measurements of all biosensors indicated a coefficient of variation (CV) between 1.55 and 3.16% with an SD from 0.042 to 0.053 mmol/L. The test-strip device (Lactate Pro) mounted to 0.117 mmol/L and 3.99% (SD, CV). When compared to our reference value (refval) ABL 625 showed the closest correlation of -0.1%, while Siemens RapidLab 865 showed an overestimation of +8.9%, ABL700 an underestimation of -6.2% and Lactate Pro of -3.7%. For routine use all tested biosensors show sufficient precision. The test-strip device shows a slightly higher standard deviation. A direct comparison of measured lactate values from the various devices needs to be interpreted with caution as each method detects different lactate concentrations. Furthermore, the 40 min process of tonometry led to an increase of SD and coefficient of variation in all devices. This results in the important preanalytical finding that the precision of replicated measurements worsens significantly with time. The clinician should be aware of the type of analyser used and of preanalytical biases before making clinical decisions on the basis of lactate values.

  3. Evolvable Neuronal Paths: A Novel Basis for Information and Search in the Brain

    PubMed Central

    Fernando, Chrisantha; Vasas, Vera; Szathmáry, Eörs; Husbands, Phil

    2011-01-01

    We propose a previously unrecognized kind of informational entity in the brain that is capable of acting as the basis for unlimited hereditary variation in neuronal networks. This unit is a path of activity through a network of neurons, analogous to a path taken through a hidden Markov model. To prove in principle the capabilities of this new kind of informational substrate, we show how a population of paths can be used as the hereditary material for a neuronally implemented genetic algorithm, (the swiss-army knife of black-box optimization techniques) which we have proposed elsewhere could operate at somatic timescales in the brain. We compare this to the same genetic algorithm that uses a standard ‘genetic’ informational substrate, i.e. non-overlapping discrete genotypes, on a range of optimization problems. A path evolution algorithm (PEA) is defined as any algorithm that implements natural selection of paths in a network substrate. A PEA is a previously unrecognized type of natural selection that is well suited for implementation by biological neuronal networks with structural plasticity. The important similarities and differences between a standard genetic algorithm and a PEA are considered. Whilst most experiments are conducted on an abstract network model, at the conclusion of the paper a slightly more realistic neuronal implementation of a PEA is outlined based on Izhikevich spiking neurons. Finally, experimental predictions are made for the identification of such informational paths in the brain. PMID:21887266

  4. Obstructive sleep apnea and postoperative complications in patients undergoing coronary artery bypass graft surgery: a need for preventive strategies.

    PubMed

    Amra, Babak; Niknam, Nasim; Sadeghi, Mohsen Mir Mohammad; Rabbani, Majid; Fietze, Ingo; Penzel, Thomas

    2014-11-01

    Obstructive sleep apnea (OSA) is very frequent and often unrecognized in surgical patients. OSA is associated with perioperative complications. We evaluated the effects of OSA on postoperative complications and hospital outcomes in patients undergoing coronary artery bypass graft (CABG) surgery. Candidates of elective CABG were evaluated by the Berlin questionnaire for OSA. After surgery, patients were assessed for postoperative complications, re-admission to the Intensive Care Unit (ICU), duration of intubation, re-intubation, days spent in the ICU and the hospital. We studied 61 patients who underwent CABG from which 25 (40.9%) patients had OSA. Patients with OSA had higher body mass index (29.5 ± 3.9 vs. 26.0 ± 3.7 kg/m(2), P = 0.003) and higher frequency of hypertension (68.0% vs. 30.5%, P = 0.003), dyslipidemia (36.0% vs. 5.5%, P = 0.004), and pulmonary disease (16.0 vs. 2.7%, P = 0.08). Regarding the surgical outcomes, OSA patients had longer intubation duration (0.75 ± 0.60 vs. 0.41 ± 0.56 days, P = 0.03). Obstructive sleep apnea is frequent, but unrecognized among patients undergoing CABG. In these patients, OSA is associated with prolonged intubation duration. Preventing these problems may be possible by early diagnosis and management of OSA in cardiac surgery patients. Further studies with larger sample of patients and longer follow-ups are required in this regard.

  5. A single macrolichen constitutes hundreds of unrecognized species

    PubMed Central

    Lücking, Robert; Dal-Forno, Manuela; Sikaroodi, Masoumeh; Gillevet, Patrick M.; Bungartz, Frank; Moncada, Bibiana; Yánez-Ayabaca, Alba; Chaves, José Luis; Coca, Luis Fernando; Lawrey, James D.

    2014-01-01

    The number of Fungi is estimated at between 1.5 and 3 million. Lichenized species are thought to make up a comparatively small portion of this figure, with unrecognized species richness hidden among little-studied, tropical microlichens. Recent findings, however, suggest that some macrolichens contain a large number of unrecognized taxa, increasing known species richness by an order of magnitude or more. Here we report the existence of at least 126 species in what until recently was believed to be a single taxon: the basidiolichen fungus Dictyonema glabratum, also known as Cora pavonia. Notably, these species are not cryptic but morphologically distinct. A predictive model suggests an even larger number, with more than 400 species. These results call into question species concepts in presumably well-known macrolichens and demonstrate the need for accurately documenting such species richness, given the importance of these lichens in endangered ecosystems such as paramos and the alarming potential for species losses throughout the tropics. PMID:24982168

  6. Anatomy of a Hotspot: Chain and Seroepidemiology of Ebola Virus Transmission, Sukudu, Sierra Leone, 2015-16.

    PubMed

    Kelly, J Daniel; Barrie, Mohamed Bailor; Mesman, Annelies W; Karku, Sahr; Quiwa, Komba; Drasher, Michael; Schlough, Gabriel Warren; Dierberg, Kerry; Koedoyoma, Songor; Lindan, Christina P; Jones, James Holland; Chamie, Gabriel; Worden, Lee; Greenhouse, Bryan; Weiser, Sheri D; Porco, Travis C; Rutherford, George W; Richardson, Eugene T

    2018-03-28

    Studies have yet to include minimally symptomatic Ebola virus (EBOV) infections and unrecognized Ebola virus disease (EVD) in Ebola-related transmission chains and epidemiologic risk estimates. We conducted a cross-sectional, sero-epidemiological survey from October 2015 to January 2016 among 221 individuals living in quarantined households from November 2014 to February 2015 during the Ebola outbreak in the village of Sukudu, Sierra Leone. Of 48 EBOV-infected persons, 25% (95% confidence interval [CI], 14%-40%) had minimally symptomatic EBOV infections and 4% (95% CI, 1%-14%) were unrecognized EVD cases. The pattern of minimally symptomatic EBOV infections in the transmission chain was nonrandom (P < .001, permutation test). Not having lived in the same house as an EVD case was significantly associated with minimally symptomatic infection. This is the first study to investigate a chain of EBOV transmission inclusive of minimally symptomatic EBOV infections and unrecognized EVD. Our findings provide new insights into Ebola transmission dynamics and quarantine practices.

  7. Diagnostic procedures for non-small-cell lung cancer (NSCLC): recommendations of the European Expert Group

    PubMed Central

    Dietel, Manfred; Bubendorf, Lukas; Dingemans, Anne-Marie C; Dooms, Christophe; Elmberger, Göran; García, Rosa Calero; Kerr, Keith M; Lim, Eric; López-Ríos, Fernando; Thunnissen, Erik; Van Schil, Paul E; von Laffert, Maximilian

    2016-01-01

    Background There is currently no Europe-wide consensus on the appropriate preanalytical measures and workflow to optimise procedures for tissue-based molecular testing of non-small-cell lung cancer (NSCLC). To address this, a group of lung cancer experts (see list of authors) convened to discuss and propose standard operating procedures (SOPs) for NSCLC. Methods Based on earlier meetings and scientific expertise on lung cancer, a multidisciplinary group meeting was aligned. The aim was to include all relevant aspects concerning NSCLC diagnosis. After careful consideration, the following topics were selected and each was reviewed by the experts: surgical resection and sampling; biopsy procedures for analysis; preanalytical and other variables affecting quality of tissue; tissue conservation; testing procedures for epidermal growth factor receptor, anaplastic lymphoma kinase and ROS proto-oncogene 1, receptor tyrosine kinase (ROS1) in lung tissue and cytological specimens; as well as standardised reporting and quality control (QC). Finally, an optimal workflow was described. Results Suggested optimal procedures and workflows are discussed in detail. The broad consensus was that the complex workflow presented can only be executed effectively by an interdisciplinary approach using a well-trained team. Conclusions To optimise diagnosis and treatment of patients with NSCLC, it is essential to establish SOPs that are adaptable to the local situation. In addition, a continuous QC system and a local multidisciplinary tumour-type-oriented board are essential. PMID:26530085

  8. ASVCP quality assurance guidelines: control of preanalytical, analytical, and postanalytical factors for urinalysis, cytology, and clinical chemistry in veterinary laboratories.

    PubMed

    Gunn-Christie, Rebekah G; Flatland, Bente; Friedrichs, Kristen R; Szladovits, Balazs; Harr, Kendal E; Ruotsalo, Kristiina; Knoll, Joyce S; Wamsley, Heather L; Freeman, Kathy P

    2012-03-01

    In December 2009, the American Society for Veterinary Clinical Pathology (ASVCP) Quality Assurance and Laboratory Standards committee published the updated and peer-reviewed ASVCP Quality Assurance Guidelines on the Society's website. These guidelines are intended for use by veterinary diagnostic laboratories and veterinary research laboratories that are not covered by the US Food and Drug Administration Good Laboratory Practice standards (Code of Federal Regulations Title 21, Chapter 58). The guidelines have been divided into 3 reports: (1) general analytical factors for veterinary laboratory performance and comparisons; (2) hematology, hemostasis, and crossmatching; and (3) clinical chemistry, cytology, and urinalysis. This particular report is one of 3 reports and documents recommendations for control of preanalytical, analytical, and postanalytical factors related to urinalysis, cytology, and clinical chemistry in veterinary laboratories and is adapted from sections 1.1 and 2.2 (clinical chemistry), 1.3 and 2.5 (urinalysis), 1.4 and 2.6 (cytology), and 3 (postanalytical factors important in veterinary clinical pathology) of these guidelines. These guidelines are not intended to be all-inclusive; rather, they provide minimal guidelines for quality assurance and quality control for veterinary laboratory testing and a basis for laboratories to assess their current practices, determine areas for improvement, and guide continuing professional development and education efforts. © 2012 American Society for Veterinary Clinical Pathology.

  9. ASVCP quality assurance guidelines: control of preanalytical and analytical factors for hematology for mammalian and nonmammalian species, hemostasis, and crossmatching in veterinary laboratories.

    PubMed

    Vap, Linda M; Harr, Kendal E; Arnold, Jill E; Freeman, Kathleen P; Getzy, Karen; Lester, Sally; Friedrichs, Kristen R

    2012-03-01

    In December 2009, the American Society for Veterinary Clinical Pathology (ASVCP) Quality Assurance and Laboratory Standards committee published the updated and peer-reviewed ASVCP Quality Assurance Guidelines on the Society's website. These guidelines are intended for use by veterinary diagnostic laboratories and veterinary research laboratories that are not covered by the US Food and Drug Administration Good Laboratory Practice standards (Code of Federal Regulations Title 21, Chapter 58). The guidelines have been divided into 3 reports: (1) general analytical factors for veterinary laboratory performance and comparisons; (2) hematology, hemostasis, and crossmatching; and (3) clinical chemistry, cytology, and urinalysis. This particular report is one of 3 reports and provides recommendations for control of preanalytical and analytical factors related to hematology for mammalian and nonmammalian species, hemostasis testing, and crossmatching and is adapted from sections 1.1 and 2.3 (mammalian hematology), 1.2 and 2.4 (nonmammalian hematology), 1.5 and 2.7 (hemostasis testing), and 1.6 and 2.8 (crossmatching) of the complete guidelines. These guidelines are not intended to be all-inclusive; rather, they provide minimal guidelines for quality assurance and quality control for veterinary laboratory testing and a basis for laboratories to assess their current practices, determine areas for improvement, and guide continuing professional development and education efforts. © 2012 American Society for Veterinary Clinical Pathology.

  10. Quality assurance in the pre-analytical phase of human urine samples by (1)H NMR spectroscopy.

    PubMed

    Budde, Kathrin; Gök, Ömer-Necmi; Pietzner, Maik; Meisinger, Christine; Leitzmann, Michael; Nauck, Matthias; Köttgen, Anna; Friedrich, Nele

    2016-01-01

    Metabolomic approaches investigate changes in metabolite profiles, which may reflect changes in metabolic pathways and provide information correlated with a specific biological process or pathophysiology. High-resolution (1)H NMR spectroscopy is used to identify metabolites in biofluids and tissue samples qualitatively and quantitatively. This pre-analytical study evaluated the effects of storage time and temperature on (1)H NMR spectra from human urine in two settings. Firstly, to evaluate short time effects probably due to acute delay in sample handling and secondly, the effect of prolonged storage up to one month to find markers of sample miss-handling. A number of statistical procedures were used to assess the differences between samples stored under different conditions, including Projection to Latent Structure Discriminant Analysis (PLS-DA), non-parametric testing as well as mixed effect linear regression analysis. The results indicate that human urine samples can be stored at 10 °C for 24 h or at -80 °C for 1 month, as no relevant changes in (1)H NMR fingerprints were observed during these time periods and temperature conditions. However, some metabolites most likely of microbial origin showed alterations during prolonged storage but without facilitating classification. In conclusion, the presented protocol for urine sample handling and semi-automatic metabolite quantification is suitable for large-scale epidemiological studies. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Preanalytical variables in measurement of free (ionized) calcium in lithium heparin-containing blood collection tubes.

    PubMed

    Haverstick, Doris M; Brill, Louis B; Scott, Mitchell G; Bruns, David E

    2009-05-01

    Measurements of free (ionized) calcium (iCa) are increasingly requested in patient care locations where immediate analysis is unavailable. Evacuated blood collection tubes containing lithium heparin and gel separator material are widely used in clinical laboratories, but little information is available on the effects of these tubes or of delay prior to analysis on the concentration or stability of iCa. We collected blood from volunteers into lithium-heparin tubes (PST, Vacutainer PST, BD Pre-Analytic Systems) of multiple lots and into electrolyte-balanced heparin syringes (Portex Dry Heparin, Smiths Medical). iCa was measured (Siemens 1265 blood gas analyzers) immediately and, in PST, at 0-7 h with or without transportation of the tubes from remote sites. The mean difference of free calcium results in the PST tubes and electrolyte-balanced syringes was -0.08 (95% confidence interval -0.17 to 0.012) mmol/l, and the SD of the residuals (Sy, x) of the regression was 0.03 mmol/l. There was no detectable lot-to-lot variation in results. Free calcium was stable in tubes at room temperature and at 4 degrees C for at least 7 h with or without transportation. iCa measured in the examined blood collection tubes is stable and unaffected by lot-to-lot variation of tubes, but results are slightly lower than with special blood gas syringes.

  12. Dried Blood Spots - Preparing and Processing for Use in Immunoassays and in Molecular Techniques

    PubMed Central

    Grüner, Nico; Stambouli, Oumaima; Ross, R. Stefan

    2015-01-01

    The idea of collecting blood on a paper card and subsequently using the dried blood spots (DBS) for diagnostic purposes originated a century ago. Since then, DBS testing for decades has remained predominantly focused on the diagnosis of infectious diseases especially in resource-limited settings or the systematic screening of newborns for inherited metabolic disorders and only recently have a variety of new and innovative DBS applications begun to emerge. For many years, pre-analytical variables were only inappropriately considered in the field of DBS testing and even today, with the exception of newborn screening, the entire pre-analytical phase, which comprises the preparation and processing of DBS for their final analysis has not been standardized. Given this background, a comprehensive step-by-step protocol, which covers al the essential phases, is proposed, i.e., collection of blood; preparation of blood spots; drying of blood spots; storage and transportation of DBS; elution of DBS, and finally analyses of DBS eluates. The effectiveness of this protocol was first evaluated with 1,762 coupled serum/DBS pairs for detecting markers of hepatitis B virus, hepatitis C virus, and human immunodeficiency virus infections on an automated analytical platform. In a second step, the protocol was utilized during a pilot study, which was conducted on active drug users in the German cities of Berlin and Essen. PMID:25867233

  13. A review of blood sample handling and pre-processing for metabolomics studies.

    PubMed

    Hernandes, Vinicius Veri; Barbas, Coral; Dudzik, Danuta

    2017-09-01

    Metabolomics has been found to be applicable to a wide range of clinical studies, bringing a new era for improving clinical diagnostics, early disease detection, therapy prediction and treatment efficiency monitoring. A major challenge in metabolomics, particularly untargeted studies, is the extremely diverse and complex nature of biological specimens. Despite great advances in the field there still exist fundamental needs for considering pre-analytical variability that can introduce bias to the subsequent analytical process and decrease the reliability of the results and moreover confound final research outcomes. Many researchers are mainly focused on the instrumental aspects of the biomarker discovery process, and sample related variables sometimes seem to be overlooked. To bridge the gap, critical information and standardized protocols regarding experimental design and sample handling and pre-processing are highly desired. Characterization of a range variation among sample collection methods is necessary to prevent results misinterpretation and to ensure that observed differences are not due to an experimental bias caused by inconsistencies in sample processing. Herein, a systematic discussion of pre-analytical variables affecting metabolomics studies based on blood derived samples is performed. Furthermore, we provide a set of recommendations concerning experimental design, collection, pre-processing procedures and storage conditions as a practical review that can guide and serve for the standardization of protocols and reduction of undesirable variation. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. A contrarian view of the five-factor approach to personality description.

    PubMed

    Block, J

    1995-03-01

    The 5-factor approach (FFA) to personality description has been represented as a comprehensive and compelling rubric for assessment. In this article, various misgivings about the FFA are delineated. The algorithmic method of factor analysis may not provide dimensions that are incisive. The "discovery" of the five factors may be influenced by unrecognized constraints on the variable sets analyzed. Lexical analyses are based on questionable conceptual and methodological assumptions, and have achieved uncertain results. The questionnaire version of the FFA has not demonstrated the special merits and sufficiencies of the five factors settled upon. Serious uncertainties have arisen in regard to the claimed 5-factor structure and the substantive meanings of the factors. Some implications of these problems are drawn.

  15. Tunneling study of cavity grade Nb : possible magnetic scattering at the surface.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prolier, T.; Zasadzinski, J. F.; Cooley, L.

    Tunneling spectroscopy was performed on Nb pieces prepared by the same processes used to etch and clean superconducting radio frequency (SRF) cavities. Air exposed, electropolished Nb exhibited a surface superconducting gap {Delta} = 1.55 meV, which is characteristic of a clean, bulk Nb. However, the tunneling density of states (DOS) was significantly broadened. The Nb pieces, which were treated with the same mild baking used to improve the Q slope in SRF cavities, reveal a sharper DOS. Good fits to the DOS were obtained by using the Shiba theory, suggesting that magnetic scattering of quasiparticles is the origin of themore » gapless surface superconductivity and a heretofore unrecognized contributor to the Q-slope problem of Nb SRF cavities.« less

  16. Effective estimation of correct platelet counts in pseudothrombocytopenia using an alternative anticoagulant based on magnesium salt

    PubMed Central

    Schuff-Werner, Peter; Steiner, Michael; Fenger, Sebastian; Gross, Hans-Jürgen; Bierlich, Alexa; Dreissiger, Katrin; Mannuß, Steffen; Siegert, Gabriele; Bachem, Maximilian; Kohlschein, Peter

    2013-01-01

    Pseudothrombocytopenia remains a challenge in the haematological laboratory. The pre-analytical problem that platelets tend to easily aggregate in vitro, giving rise to lower platelet counts, has been known since ethylenediamine-tetra acetic acid EDTA and automated platelet counting procedures were introduced in the haematological laboratory. Different approaches to avoid the time and temperature dependent in vitro aggregation of platelets in the presence of EDTA were tested, but none of them proved optimal for routine purposes. Patients with unexpectedly low platelet counts or flagged for suspected aggregates, were selected and smears were examined for platelet aggregates. In these cases patients were asked to consent to the drawing of an additional sample of blood anti-coagulated with a magnesium additive. Magnesium was used in the beginning of the last century as anticoagulant for microscopic platelet counts. Using this approach, we documented 44 patients with pseudothrombocytopenia. In all cases, platelet counts were markedly higher in samples anti-coagulated with the magnesium containing anticoagulant when compared to EDTA-anticoagulated blood samples. We conclude that in patients with known or suspected pseudothrombocytopenia the magnesium-anticoagulant blood samples may be recommended for platelet counting. PMID:23808903

  17. Lean six sigma methodologies improve clinical laboratory efficiency and reduce turnaround times.

    PubMed

    Inal, Tamer C; Goruroglu Ozturk, Ozlem; Kibar, Filiz; Cetiner, Salih; Matyar, Selcuk; Daglioglu, Gulcin; Yaman, Akgun

    2018-01-01

    Organizing work flow is a major task of laboratory management. Recently, clinical laboratories have started to adopt methodologies such as Lean Six Sigma and some successful implementations have been reported. This study used Lean Six Sigma to simplify the laboratory work process and decrease the turnaround time by eliminating non-value-adding steps. The five-stage Six Sigma system known as define, measure, analyze, improve, and control (DMAIC) is used to identify and solve problems. The laboratory turnaround time for individual tests, total delay time in the sample reception area, and percentage of steps involving risks of medical errors and biological hazards in the overall process are measured. The pre-analytical process in the reception area was improved by eliminating 3 h and 22.5 min of non-value-adding work. Turnaround time also improved for stat samples from 68 to 59 min after applying Lean. Steps prone to medical errors and posing potential biological hazards to receptionists were reduced from 30% to 3%. Successful implementation of Lean Six Sigma significantly improved all of the selected performance metrics. This quality-improvement methodology has the potential to significantly improve clinical laboratories. © 2017 Wiley Periodicals, Inc.

  18. A comparative study of family functioning, health, and mental health awareness and utilization among female Bedouin-Arabs from recognized and unrecognized villages in the Negev.

    PubMed

    Al-Krenawi, Alean; Graham, John R

    2006-02-01

    A good portion of geography is contested by the Israeli state and the country's Bedouin-Arab population. There are two categories of Bedouin villages: those areas that are "officially" recognized by the state and those that are not. In this article we determine utilization and awareness of health and mental health services among 376 Bedouin-Arab women in recognized and unrecognized villages in the Negev. Although there are differences between them, primary health care (PHC) services usually are available within recognized villages, accessible to those from unrecognized villages, and tend to precipitate user satisfaction. We conclude with various suggestions for improving health service delivery and making PHC and mental health delivery more accessible. Through this article we intend to help mental health practitioners on two levels: the policy level, regarding the design of mental health services for societies in transition, such as the Bedouin Arab, and the practical level by helping practitioners better appreciate the psychosocial status of women in Bedouin-Arab societies and the factors associated with Bedouin-Arab PHC utilization.

  19. The Henry Ford Production System: LEAN Process Redesign Improves Service in the Molecular Diagnostic Laboratory

    PubMed Central

    Cankovic, Milena; Varney, Ruan C.; Whiteley, Lisa; Brown, Ron; D'Angelo, Rita; Chitale, Dhananjay; Zarbo, Richard J.

    2009-01-01

    Accurate and timely molecular test results play an important role in patient management; consequently, there is a customer expectation of short testing turnaround times. Baseline data analysis revealed that the greatest challenge to timely result generation occurred in the preanalytic phase of specimen collection and transport. Here, we describe our efforts to improve molecular testing turnaround times by focusing primarily on redesign of preanalytic processes using the principles of LEAN production. Our goal was to complete greater than 90% of the molecular tests in less than 3 days. The project required cooperation from different laboratory disciplines as well as individuals outside of the laboratory. The redesigned processes involved defining and standardizing the protocols and approaching blood and tissue specimens as analytes for molecular testing. The LEAN process resulted in fewer steps, approaching the ideal of a one-piece flow for specimens through collection/retrieval, transport, and different aspects of the testing process. The outcome of introducing the LEAN process has been a 44% reduction in molecular test turnaround time for tissue specimens, from an average of 2.7 to 1.5 days. In addition, extending LEAN work principles to the clinician suppliers has resulted in a markedly increased number of properly collected and shipped blood specimens (from 50 to 87%). These continuous quality improvements were accomplished by empowered workers in a blame-free environment and are now being sustained with minimal management involvement. PMID:19661386

  20. Cytological preparations for molecular analysis: A review of technical procedures, advantages and limitations for referring samples for testing.

    PubMed

    da Cunha Santos, G; Saieg, M A; Troncone, G; Zeppa, P

    2018-04-01

    Minimally invasive procedures such as endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) must yield not only good quality and quantity of material for morphological assessment, but also an adequate sample for analysis of molecular markers to guide patients to appropriate targeted therapies. In this context, cytopathologists worldwide should be familiar with minimum requirements for refereeing cytological samples for testing. The present manuscript is a review with comprehensive description of the content of the workshop entitled Cytological preparations for molecular analysis: pre-analytical issues for EBUS TBNA, presented at the 40th European Congress of Cytopathology in Liverpool, UK. The present review emphasises the advantages and limitations of different types of cytology substrates used for molecular analysis such as archival smears, liquid-based preparations, archival cytospin preparations and FTA (Flinders Technology Associates) cards, as well as their technical requirements/features. These various types of cytological specimens can be successfully used for an extensive array of molecular studies, but the quality and quantity of extracted nucleic acids rely directly on adequate pre-analytical assessment of those samples. In this setting, cytopathologists must not only be familiar with the different types of specimens and associated technical procedures, but also correctly handle the material provided by minimally invasive procedures, ensuring that there is sufficient amount of material for a precise diagnosis and correct management of the patient through personalised care. © 2018 John Wiley & Sons Ltd.

  1. Two methods for proteomic analysis of formalin-fixed, paraffin embedded tissue result in differential protein identification, data quality, and cost.

    PubMed

    Luebker, Stephen A; Wojtkiewicz, Melinda; Koepsell, Scott A

    2015-11-01

    Formalin-fixed paraffin-embedded (FFPE) tissue is a rich source of clinically relevant material that can yield important translational biomarker discovery using proteomic analysis. Protocols for analyzing FFPE tissue by LC-MS/MS exist, but standardization of procedures and critical analysis of data quality is limited. This study compared and characterized data obtained from FFPE tissue using two methods: a urea in-solution digestion method (UISD) versus a commercially available Qproteome FFPE Tissue Kit method (Qkit). Each method was performed independently three times on serial sections of homogenous FFPE tissue to minimize pre-analytical variations and analyzed with three technical replicates by LC-MS/MS. Data were evaluated for reproducibility and physiochemical distribution, which highlighted differences in the ability of each method to identify proteins of different molecular weights and isoelectric points. Each method replicate resulted in a significant number of new protein identifications, and both methods identified significantly more proteins using three technical replicates as compared to only two. UISD was cheaper, required less time, and introduced significant protein modifications as compared to the Qkit method, which provided more precise and higher protein yields. These data highlight significant variability among method replicates and type of method used, despite minimizing pre-analytical variability. Utilization of only one method or too few replicates (both method and technical) may limit the subset of proteomic information obtained. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Laboratory testing of extravascular body fluids in Croatia: a survey of the Working group for extravascular body fluids of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    PubMed

    Kopcinovic, Lara Milevoj; Vogrinc, Zeljka; Kocijan, Irena; Culej, Jelena; Aralica, Merica; Jokic, Anja; Antoncic, Dragana; Bozovic, Marija

    2016-10-15

    We hypothesized that extravascular body fluid (EBF) analysis in Croatia is not harmonized and aimed to investigate preanalytical, analytical and postanalytical procedures used in EBF analysis in order to identify key aspects that should be addressed in future harmonization attempts. An anonymous online survey created to explore laboratory testing of EBF was sent to secondary, tertiary and private health care Medical Biochemistry Laboratories (MBLs) in Croatia. Statements were designed to address preanalytical, analytical and postanalytical procedures of cerebrospinal, pleural, peritoneal (ascites), pericardial, seminal, synovial, amniotic fluid and sweat. Participants were asked to declare the strength of agreement with proposed statements using a Likert scale. Mean scores for corresponding separate statements divided according to health care setting were calculated and compared. The survey response rate was 0.64 (58 / 90). None of the participating private MBLs declared to analyse EBF. We report a mean score of 3.45 obtained for all statements evaluated. Deviations from desirable procedures were demonstrated in all EBF testing phases. Minor differences in procedures used for EBF analysis comparing secondary and tertiary health care MBLs were found. The lowest scores were obtained for statements regarding quality control procedures in EBF analysis, participation in proficiency testing programmes and provision of interpretative comments on EBF's test reports. Although good laboratory EBF practice is present in Croatia, procedures for EBF analysis should be further harmonized to improve the quality of EBF testing and patient safety.

  3. Assuring the Quality of Test Results in the Field of Nuclear Techniques and Ionizing Radiation. The Practical Implementation of Section 5.9 of the EN ISO/IEC 17025 Standard

    NASA Astrophysics Data System (ADS)

    Cucu, Daniela; Woods, Mike

    2008-08-01

    The paper aims to present a practical approach for testing laboratories to ensure the quality of their test results. It is based on the experience gained in assessing a large number of testing laboratories, discussing with management and staff, reviewing results obtained in national and international PTs and ILCs and exchanging information in the EA laboratory committee. According to EN ISO/IEC 17025, an accredited laboratory has to implement a programme to ensure the quality of its test results for each measurand. Pre-analytical, analytical and post-analytical measures shall be applied in a systematic manner. They shall include both quality control and quality assurance measures. When designing the quality assurance programme a laboratory should consider pre-analytical activities (like personnel training, selection and validation of test methods, qualifying equipment), analytical activities ranging from sampling, sample preparation, instrumental analysis and post-analytical activities (like decoding, calculation, use of statistical tests or packages, management of results). Designed on different levels (analyst, quality manager and technical manager), including a variety of measures, the programme shall ensure the validity and accuracy of test results, the adequacy of the management system, prove the laboratory's competence in performing tests under accreditation and last but not least show the comparability of test results. Laboratory management should establish performance targets and review periodically QC/QA results against them, implementing appropriate measures in case of non-compliance.

  4. Post-sampling release of free fatty acids - effects of heat stabilization and methods of euthanasia.

    PubMed

    Jernerén, Fredrik; Söderquist, Marcus; Karlsson, Oskar

    2015-01-01

    The field of lipid research has made progress and it is now possible to study the lipidome of cells and organelles. A basic requirement of a successful lipid study is adequate pre-analytical sample handling, as some lipids can be unstable and postmortem changes can cause substantial accumulation of free fatty acids (FFAs). The aim of the present study was to investigate the effects of conductive heat stabilization and euthanasia methods on FFA levels in the rat brain and liver using liquid chromatography tandem mass spectrometry. The analysis of brain homogenates clearly demonstrated phospholipase activity and time-dependent post-sampling changes in the lipid pool of snap frozen non-stabilized tissue. There was a significant increase in FFAs already at 2min, which continued over time. Heat stabilization was shown to be an efficient method to reduce phospholipase activity and ex vivo lipolysis. Post-sampling effects due to tissue thawing and sample preparation induced a massive release of FFAs (up to 3700%) from non-stabilized liver and brain tissues compared to heat stabilized tissue. Furthermore, the choice of euthanasia method significantly influenced the levels of FFAs in the brain. The FFAs were decreased by 15-44% in the group of animals euthanized by pentobarbital injection compared with CO2 inhalation or decapitation. Our results highlight the importance of considering euthanasia methods and pre-analytical treatment in lipid analysis, factors which may otherwise interfere with the outcome of the experiments. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Science and education across cultures: another look at the Negev Bedouins and their environmental management practices

    NASA Astrophysics Data System (ADS)

    Saito, Carlos Hiroo

    2014-12-01

    This is a rejoinder to the original article written by Wisam Sedawi, Orit Ben Zvi Assaraf, and Julie Cwikel about waste-related implication on the welfare of children living in the Negev's Bedouin Arab community. More specifically, the authors discuss the role of environmental education in the improvement of participants' life conditions. They do so by analyzing the impact of current precarious waste management practices on children's health and proposing the implementation of a science study unit in school that could assist them in dealing with the problem. My argument here is divided in three parts: first, based on the original article's information, I comment on some important characteristics of those unrecognized settlements and their waste production practices; second, I try to determine what kind of environmental education—if any—is necessary in that context to promote the desired changes put forward by the authors; and third, I adopt a cross-cultural approach to science and environmental literacy as means to provoke readers to consider the scientific value (often neglected) of traditional knowledge in attempting to solve the issues described in the original paper. In addition, both the Tbilisi Intergovernmental Conference on Environmental Education (1977) and the Treaty on Environmental Education for Sustainable Societies and Global Responsibility (1992) are used to support my argument, which also encompasses the concept of empowerment. Ultimately, bridging the Bedouin's traditional knowledge and Western modern science can help to improve science education at the school level in the unrecognized township under study by linking present and past in search of a more sustainable and peaceful future.

  6. Intestinal Perforation Following Ileoscopy Through a Prolapsed Stoma in an Pediatric Intestinal Transplant Recipient With an Unrecognized Parastomal Hernia

    PubMed Central

    Yeh, Joanna; Hall, Theodore R.; Agopian, Vatche G.; Farmer, Douglas G.; Marcus, Elizabeth A.; Venick, Robert S.; Wozniak, Laura J.

    2016-01-01

    Ileoscopy with mucosal biopsy is fundamental in the management and surveillance of inflammatory bowel disease patients and intestinal transplant recipients. There is a paucity of data describing the risks of ileoscopy in the presence of a prolapsed stoma. Parastomal hernias are frequently associated with prolapsed stomas. We report the first case of perforation during ileoscopy in the setting of a prolapsed stoma and unrecognized parastomal hernia. Recognition of parastomal hernia associated with stoma prolapse is of paramount importance in patients undergoing ileoscopy as it may increase the risk of perforation. PMID:27807575

  7. Chronic sinusitis associated with the use of unrecognized bone substitute: a case report.

    PubMed

    Beklen, Arzu; Pihakari, Antti; Rautemaa, Riina; Hietanen, Jarkko; Ali, Ahmed; Konttinen, Yrjö T

    2008-05-01

    Bone grafts are used for bone augmentation to ensure optimal implant placement. However, this procedure may sometimes cause sinusitis. The case of a 44-year-old woman with the diagnosis of recurrent and chronic sinusitis of her right maxillary sinus with a history of dental implant surgery is presented. After several attempts with normal standard sinusitis therapy, unrecognized bone substitute was removed from the sinus cavity, which finally led to resolution of the sinusitis. This case reiterates the importance of a careful examination, consultation, and second opinion for the selection of optimal treatment.

  8. Stress, burnout, and maladaptive coping: strategies for surgeon well-being.

    PubMed

    Bittner, James G; Khan, Zarrish; Babu, Maya; Hamed, Osama

    2011-08-01

    Practicing physicians and surgeons, medical and surgical residents, and medical students dedicate their lives to providing optimum patient care, but doing so places them at significant risk for personal and professional stress and, ultimately, burnout. Of great concern is the fact that unrecognized stress and unmanaged burnout are more prevalent among residents than previously believed. Research shows that stress without conflict resolution may lead to burnout, which can contribute to impaired technical performance, medical errors, physical and mental health problems, and even increase the risk of suicide. Therefore, it is crucial that surgeons, and the organizations that train and employ them, recognize the early signs of stress and burnout, adopt adaptive coping strategies, and maintain a culture wherein work-life balance and surgeon well-being are shared goals.

  9. Proton pump inhibitors and symptomatic hypomagnesemic hypoparathyroidism.

    PubMed

    Fatuzzo, P; Portale, G; Scollo, V; Zanoli, L; Granata, Antonio

    2017-04-01

    Hypomagnesemia is a common but often overlooked problem in hospitalized patients. Unrecognized hypomagnesemia can cause serious complications. The association of hypokalemia and hypocalcemia is strongly evocative of a magnesium deficiency. Research into the causes of hypomagnesemia is imperative, as it will definitely change the approach, treatment and prognosis. We report the case of a 65-year-old man with chronic hypocalcemia and hypokalemia associated with cerebellar syndrome, a solitary seizure and cerebellar hyperintensities on magnetic resonance imaging. After the detection and treatment of hypomagnesemia with oral supplements of magnesium and the replacement of pantoprazole with ranitidine, we observed immediate relief of the symptoms. In conclusion, in clinical practice, magnesium depletion should be investigated in elderly patients with hypocalcemia treated with proton pump inhibitors for many years, in particular in the presence of neurological disorders.

  10. MR imaging in sports-related glenohumeral instability

    PubMed Central

    Waldt, Simone

    2006-01-01

    Sports-related shoulder pain and injuries represent a common problem. In this context, glenohumeral instability is currently believed to play a central role either as a recognized or as an unrecognized condition. Shoulder instabilities can roughly be divided into traumatic, atraumatic, and microtraumatic glenohumeral instabilities. In athletes, atraumatic and microtraumatic instabilities can lead to secondary impingement syndromes and chronic damage to intraarticular structures. Magnetic resonance (MR) arthrography is superior to conventional MR imaging in the diagnosis of labro-ligamentous injuries, intrinsic impingement, and SLAP (superior labral anteroposterior) lesions, and thus represents the most informative imaging modality in the overall assessment of glenohumeral instability. This article reviews the imaging criteria for the detection and classification of instability-related injuries in athletes with special emphasis on the influence of MR findings on therapeutic decisions. PMID:16633790

  11. Hearing Aid Tester

    NASA Technical Reports Server (NTRS)

    1978-01-01

    Hearing aids often develop malfunctions that are not detected by the wearer. This is particularly true when the wearers are school-age children. Studies of selected groups showed that from 30 to more than 50 percent of school children were not getting adequate benefit from their hearing aids because of unrecognized malfunctions, usually low or dead batteries. This can be serious because hearing impairment retards a child's educational progress. NASA technology incorporated in the Hearing Aid Malfunction Detection Unit (HAMDU), the device pictured, is expected to provide an effective countermeasure to the childrens' hearing aid problem. A patent license has been awarded to a minority-owned firm, Hopkins International Company, a subsidiary of H. H. Aerospace Design Co., Inc., Elmford, New York. The company plans early commercial availability of its version of the device.

  12. The origin of scientific neurology and its consequences for modern and future neuroscience.

    PubMed

    Steinberg, David A

    2014-01-01

    John Hughlings Jackson (1835-1911) created a science of brain function that, in scope and profundity, is among the great scientific discoveries of the 19th century. It is interesting that the magnitude of his achievement is not completely recognized even among his ardent admirers. Although thousands of practitioners around the world use the clinical applications of his science every day, the principles from which bedside neurology is derived have broader consequences-for modern and future science-that remain unrecognized and unexploited. This paper summarizes the scientific formalism that created modern neurology, demonstrates how its direct implications affect a current area of neuroscientific research, and indicates how Hughlings Jackson's ideas form a path toward a novel solution to an important open problem of the brain and mind.

  13. Survey of national guidelines, education and training on phlebotomy in 28 European countries: an original report by the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) working group for the preanalytical phase (WG-PA).

    PubMed

    Simundic, Ana-Maria; Cornes, Michael; Grankvist, Kjell; Lippi, Giuseppe; Nybo, Mads; Kovalevskaya, Svjetlana; Sprongl, Ludek; Sumarac, Zorica; Church, Stephen

    2013-08-01

    European questionnaire survey was conducted by the European Federation of Clinical Chemistry and Laboratory Medicine Working Group for the Preanalytical Phase (EFLM WG-PA) to assess how phlebotomy is performed in EFLM countries, including differences in personnel, level of education and skills, and to investigate the presence and compliance of national phlebotomy guidelines on this matter. A questionnaire was constructed containing questions elucidating different aspects of the organization behind the phlebotomy praxis on a national basis, including questions on the staff performing phlebotomy, the education of these staff members, and the existence of and adherence to national guidelines. All 39 EFLM member countries were invited to participate. In total 28/39 (72%) EFLM member countries responded. Seven out of the 28 (25%) have national phlebotomy guidelines and five have implemented other guidelines. The estimated compliance with phlebotomy guidance for the laboratories in the countries that have national guidelines available is poor, regardless to whether the phlebotomy was under the laboratory control or not. Most countries were interested in EFLM guidelines and to participate in a pilot EFLM preanalytical phase external quality assessment (EQA) scheme. In the responding EFLM member countries, the majority of phlebotomy is performed by nurses and laboratory technicians. Their basic education is generally 4-5 years of high school, followed by 2-5 years of colleague or university studies. Only a third (10/28; 36%) of the participating member countries has any specific training available as a continuous educational resource. A specific training for phlebotomy is not part of the education required to become qualified in 6/28 (21%) and 9/28 (32%) of countries for nurses and laboratory technicians, respectively. In countries and professions where training is required, most require more than 5 h of training. Based on the results of this survey we conclude the following: 1) There is a need to assess the quality of current practices, compliance to the CLSI H3-A6 guidelines and to identify some most critical steps which occur during phlebotomy, in different healthcare settings, across Europe; 2) Existing CLSI H3-A6 phlebotomy guidelines should be adapted and used locally in all European countries which do not have their own guidelines; 3) National EFLM societies need to be engaged in basic training program development and continuous education of healthcare phlebotomy staff (implementing the certification of competence).

  14. Prevalence of diabetes and unrecognized diabetes in hypertensive patients aged 40 to 79 years in southwest China

    PubMed Central

    Liu, Ya; Hu, Rong; Ouyang, Ling-yun; Liu, Jian-xiong; Li, Xiu-jun; Yi, Yan-jing; Wang, Tzung-Dau; Zhao, Shui-ping

    2017-01-01

    This study aimed to assess the prevalence of diabetes and unrecognized diabetes in hypertensive patients aged 40 to 79 years in Southwest China. From September 2013 to March 2014, a cross-sectional survey was conducted in 4021 hypertensive patients aged 40 to 79 years living in Chengdu and Chongqing, China. Fasting plasma glucose (FPG) and 2h plasma glucose (2-hPG) in an oral glucose-tolerance test (OGTT) were used for assessments. Whether the patients previously had diabetes (DM) was determined by their own reports. The survey was carried out by the same questionnaire for all respondents. DM prevalence was 32.0% in hypertensive patients aged 40 to 79 years in Southwest China, with the rates of 29.6% and 33.5% in men and women, respectively (P<0.001). DM prevalence increased with age age and body-mass index. DM prevalence rates were 16.9%, 24.7%, 38.2% and 41.9% in hypertensive patients aged 40–49, 50–59, 60–69 and over 70, respectively. DM prevalence were 30.6%, 27.9%, 37.1%, and 37.4%, for BMI<18.5, 18.5–24.9, 25.0–29.9, and ≥30, respectively. Prevalence of unrecognized DM were 20.8% in hypertensive patients aged 40 to 79 years in Southwest China. Using only fasting blood glucose testing without OGTT would have resulted in 65.0% of missed DM diagnosis in these newly diagnosed patients. The prevalence of DM and unrecognized DM were high in hypertensive patients aged 40 to 79 years in Southwest China.These findings indicate that hypertensive patients aged 40 to 79 years should regularly submit to community-based OGTT screening for timely DM diagnosis. PMID:28192474

  15. Blood transfusion-acquired hemoglobin C.

    PubMed

    Suarez, A A; Polski, J M; Grossman, B J; Johnston, M F

    1999-07-01

    Unexpected and confusing laboratory test results can occur if a blood sample is inadvertently collected following a blood transfusion. A potential for transfusion-acquired hemoglobinopathy exists because heterozygous individuals show no significant abnormalities during the blood donor screening process. Such spurious results are infrequently reported in the medical literature. We report a case of hemoglobin C passively transferred during a red blood cell transfusion. The proper interpretation in our case was assisted by calculations comparing expected hemoglobin C concentration with the measured value. A review of the literature on transfusion-related preanalytic errors is provided.

  16. [Point of Care 2.0: Coagulation Monitoring Using Rotem® Sigma and Teg® 6S].

    PubMed

    Weber, Christian Friedrich; Zacharowski, Kai

    2018-06-01

    New-generation methods for point of care based coagulation monitoring enable fully automated viscoelastic analyses for the assessment of particular parts of hemostasis. Contrary to the measuring techniques of former models, the viscoelastic ROTEM ® sigma and TEG ® 6s analyses are performed in single-use test cartridges without time- and personnel-intensive pre-analytical procedures. This review highlights methodical strengths and limitations of the devices and meets concerns associated with their integration in routine clinical practice. Georg Thieme Verlag KG Stuttgart · New York.

  17. A Republican Egalitarian Approach to Bioethics: The Case of the Unrecognized Bedouin Villages in Israel.

    PubMed

    Filc, Dani; Davidovich, Nadav; Gottlieb, Nora

    2016-10-01

    This article argues that current, mainstream, liberal approaches to the right to health and to bioethics are not adequately aware of the structural and political character of health and illness. We propose a radical egalitarian definition of the right to health as the basis for the discussion of a republican egalitarian perspective on bioethics that redefines autonomy and stresses the importance of equality, political participation, and the common good. The violations of the right to health in unrecognized Bedouin villages in Israel are analyzed to exemplify the possibilities opened by the republican egalitarian approach. © The Author(s) 2015.

  18. Unrecognized pediatric and adult family members of children with acute brucellosis.

    PubMed

    Çiftdoğan, Dilek Yılmaz; Aslan, Selda

    Brucellosis is an infectious, contagious and zoonotic disease that occurs worldwide. The family members of an index case of brucellosis may be especially susceptible, due to sharing the same source of infection and similar risk factors for brucellosis. In this study, we propose to screen pediatric and adult family members of brucellosis index cases for detecting additional unrecognized infected family members. 114 family members of 41 pediatric patients with brucellosis were evaluated. All family members completed a brief questionnaire and were tested by a standard tube agglutination test (STA). The majority of family members (n=96, 84.2%) were children. Among the 114 family members, 42 (36.8%) were seropositive, and 15 (35.7%) were symptomatic. The majority of the symptomatic seropositive family members (n=12, 80%) had STA titers (≥1:640) higher than asymptomatic seropositive family members (n=9, 33%; p=0.004). The routine screening of both pediatric and adult family members of index cases is a priority in endemic areas. Using this screening approach, unrecognized family members who are seropositive for brucellosis will be identified earlier and be able to receive prompt treatment. Copyright © 2017 Sociedade Brasileira de Infectologia. Published by Elsevier Editora Ltda. All rights reserved.

  19. Aedes Mosquitoes and Aedes-Borne Arboviruses in Africa: Current and Future Threats

    PubMed Central

    Weetman, David; Shearer, Freya M.; Coulibaly, Mamadou

    2018-01-01

    The Zika crisis drew attention to the long-overlooked problem of arboviruses transmitted by Aedes mosquitoes in Africa. Yellow fever, dengue, chikungunya and Zika are poorly controlled in Africa and often go unrecognized. However, to combat these diseases, both in Africa and worldwide, it is crucial that this situation changes. Here, we review available data on the distribution of each disease in Africa, their Aedes vectors, transmission potential, and challenges and opportunities for Aedes control. Data on disease and vector ranges are sparse, and consequently maps of risk are uncertain. Issues such as genetic and ecological diversity, and opportunities for integration with malaria control, are primarily African; others such as ever-increasing urbanization, insecticide resistance and lack of evidence for most control-interventions reflect problems throughout the tropics. We identify key knowledge gaps and future research areas, and in particular, highlight the need to improve knowledge of the distributions of disease and major vectors, insecticide resistance, and to develop specific plans and capacity for arboviral disease surveillance, prevention and outbreak responses. PMID:29382107

  20. Sodium citrate blood contamination by K2 -ethylenediaminetetraacetic acid (EDTA): impact on routine coagulation testing.

    PubMed

    Lima-Oliveira, G; Salvagno, G L; Danese, E; Favaloro, E J; Guidi, G C; Lippi, G

    2015-06-01

    The potential cross-contamination of additives between primary blood tubes is a well-known problem during sample collection. The aim of this study was to assess the impact of citrated blood contamination with different amounts of dipotassium ethylenediaminetetraacetic (K2 EDTA blood) on activated partial thromboplastin time (APTT), prothrombin time (PT), and fibrinogen. Blood was collected from 15 ostensibly healthy volunteers into four 0.109 m citrate blood tubes followed by one K2 EDTA blood tube. The citrate tubes of each subject were pooled and divided in five aliquots. The whole blood of the K2 EDTA tube was then added in scalar amounts to autologous citrated blood aliquots, to obtain K2 EDTA contamination ranging from 0% to 43%, and thus mimic potential pre-analytical contamination. A statistically and clinically significant prolongation was observed for both APTT and PT between 29% and 43% K2 EDTA contamination, whereas the decrease of fibrinogen values became statistically and clinically significant at 43% K2 EDTA contamination. The results of this investigation show that contamination of citrated blood with as much as 29% of K2 EDTA blood generates a significant bias in results of routine clotting assays. This has serious implications for patient safety and management. © 2014 John Wiley & Sons Ltd.

  1. The Effect of Pre-Analytical Variability on the Measurement of MRM-MS-Based Mid- to High-Abundance Plasma Protein Biomarkers and a Panel of Cytokines

    PubMed Central

    Aguilar-Mahecha, Adriana; Kuzyk, Michael A.; Domanski, Dominik; Borchers, Christoph H.; Basik, Mark

    2012-01-01

    Blood sample processing and handling can have a significant impact on the stability and levels of proteins measured in biomarker studies. Such pre-analytical variability needs to be well understood in the context of the different proteomics platforms available for biomarker discovery and validation. In the present study we evaluated different types of blood collection tubes including the BD P100 tube containing protease inhibitors as well as CTAD tubes, which prevent platelet activation. We studied the effect of different processing protocols as well as delays in tube processing on the levels of 55 mid and high abundance plasma proteins using novel multiple-reaction monitoring-mass spectrometry (MRM-MS) assays as well as 27 low abundance cytokines using a commercially available multiplexed bead-based immunoassay. The use of P100 tubes containing protease inhibitors only conferred proteolytic protection for 4 cytokines and only one MRM-MS-measured peptide. Mid and high abundance proteins measured by MRM are highly stable in plasma left unprocessed for up to six hours although platelet activation can also impact the levels of these proteins. The levels of cytokines were elevated when tubes were centrifuged at cold temperature, while low levels were detected when samples were collected in CTAD tubes. Delays in centrifugation also had an impact on the levels of cytokines measured depending on the type of collection tube used. Our findings can help in the development of guidelines for blood collection and processing for proteomic biomarker studies. PMID:22701622

  2. The effect of pre-analytical variability on the measurement of MRM-MS-based mid- to high-abundance plasma protein biomarkers and a panel of cytokines.

    PubMed

    Aguilar-Mahecha, Adriana; Kuzyk, Michael A; Domanski, Dominik; Borchers, Christoph H; Basik, Mark

    2012-01-01

    Blood sample processing and handling can have a significant impact on the stability and levels of proteins measured in biomarker studies. Such pre-analytical variability needs to be well understood in the context of the different proteomics platforms available for biomarker discovery and validation. In the present study we evaluated different types of blood collection tubes including the BD P100 tube containing protease inhibitors as well as CTAD tubes, which prevent platelet activation. We studied the effect of different processing protocols as well as delays in tube processing on the levels of 55 mid and high abundance plasma proteins using novel multiple-reaction monitoring-mass spectrometry (MRM-MS) assays as well as 27 low abundance cytokines using a commercially available multiplexed bead-based immunoassay. The use of P100 tubes containing protease inhibitors only conferred proteolytic protection for 4 cytokines and only one MRM-MS-measured peptide. Mid and high abundance proteins measured by MRM are highly stable in plasma left unprocessed for up to six hours although platelet activation can also impact the levels of these proteins. The levels of cytokines were elevated when tubes were centrifuged at cold temperature, while low levels were detected when samples were collected in CTAD tubes. Delays in centrifugation also had an impact on the levels of cytokines measured depending on the type of collection tube used. Our findings can help in the development of guidelines for blood collection and processing for proteomic biomarker studies.

  3. Clinical biochemistry laboratory rejection rates due to various types of preanalytical errors.

    PubMed

    Atay, Aysenur; Demir, Leyla; Cuhadar, Serap; Saglam, Gulcan; Unal, Hulya; Aksun, Saliha; Arslan, Banu; Ozkan, Asuman; Sutcu, Recep

    2014-01-01

    Preanalytical errors, along the process from the beginning of test requests to the admissions of the specimens to the laboratory, cause the rejection of samples. The aim of this study was to better explain the reasons of rejected samples, regarding to their rates in certain test groups in our laboratory. This preliminary study was designed on the rejected samples in one-year period, based on the rates and types of inappropriateness. Test requests and blood samples of clinical chemistry, immunoassay, hematology, glycated hemoglobin, coagulation and erythrocyte sedimentation rate test units were evaluated. Types of inappropriateness were evaluated as follows: improperly labelled samples, hemolysed, clotted specimen, insufficient volume of specimen and total request errors. A total of 5,183,582 test requests from 1,035,743 blood collection tubes were considered. The total rejection rate was 0.65 %. The rejection rate of coagulation group was significantly higher (2.28%) than the other test groups (P < 0.001) including insufficient volume of specimen error rate as 1.38%. Rejection rates of hemolysis, clotted specimen and insufficient volume of sample error were found to be 8%, 24% and 34%, respectively. Total request errors, particularly, for unintelligible requests were 32% of the total for inpatients. The errors were especially attributable to unintelligible requests of inappropriate test requests, improperly labelled samples for inpatients and blood drawing errors especially due to insufficient volume of specimens in a coagulation test group. Further studies should be performed after corrective and preventive actions to detect a possible decrease in rejecting samples.

  4. Validation of cell-based fluorescence assays: practice guidelines from the ICSH and ICCS - part II - preanalytical issues.

    PubMed

    Davis, Bruce H; Dasgupta, Amar; Kussick, Steven; Han, Jin-Yeong; Estrellado, Annalee

    2013-01-01

    Flow cytometry and other technologies of cell-based fluorescence assays are as a matter of good laboratory practice required to validate all assays, which when in clinical practice may pass through regulatory review processes using criteria often defined with a soluble analyte in plasma or serum samples in mind. Recently the U.S. Food and Drug Administration (FDA) has entered into a public dialogue in the U.S. regarding their regulatory interest in laboratory developed tests (LDTs) or so-called "home brew" assays performed in clinical laboratories. The absence of well-defined guidelines for validation of cell-based assays using fluorescence detection has thus become a subject of concern for the International Council for Standardization of Haematology (ICSH) and International Clinical Cytometry Society (ICCS). Accordingly, a group of over 40 international experts in the areas of test development, test validation, and clinical practice of a variety of assay types using flow cytometry and/or morphologic image analysis were invited to develop a set of practical guidelines useful to in vitro diagnostic (IVD) innovators, clinical laboratories, regulatory scientists, and laboratory inspectors. The focus of the group was restricted to fluorescence reporter reagents, although some common principles are shared by immunohistochemistry or immunocytochemistry techniques and noted where appropriate. The work product of this two year effort is the content of this special issue of this journal, which is published as 5 separate articles, this being Validation of Cell-based Fluorescence Assays: Practice Guidelines from the ICSH and ICCS - Part II - Preanalytical issues. © 2013 International Clinical Cytometry Society. © 2013 International Clinical Cytometry Society.

  5. Mobile phone exposure influences some erythrocytes parameters in vitro. A novel source of preanalytical variability?

    PubMed

    Danese, Elisa; Lippi, Giuseppe; Brocco, Giorgio; Montagnana, Martina; Salvagno, Gian Luca

    2016-06-01

    The effect of radiofrequency exposure on human health and health care equipment is a matter of ongoing debate. This study was planned to investigate the influence of radiofrequency (RF) waves emitted by a commercial mobile phone on red blood cells (RBC) in vitro. The study population consisted of 16 ostensibly healthy volunteers. Two whole blood specimens were collected from each volunteer. One sample was placed in a plastic rack, 1 cm distant from the chassis of a commercial mobile phone which was activated by a remote phone call lasting 30 min. The other blood sample was placed in another plastic rack, but was kept distant from any type of RF source. The main RBC parameters including RBC count, hematocrit (Ht), hemoglobin, mean corpuscular platelet volume (MPV), mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC) and RBC distribution width (RDW-CV) were assessed with an Advia 2120. The exposure of whole blood to the mobile phone call significantly increased Ht, hemoglobin, MCV and MCH, whereas the RBC count, MCHC and RDW-CV remained unchanged. A significant correlation was observed between variation of Ht and those of hemoglobin (p=0.008), MCV (p=0.009) or MCH (p=0.037), as well as between hemoglobin and MCV (p=0.048). Increased values were found in 13/16 (81%) samples for both Ht and hemoglobin, 14/16 (88%) samples for MCH and 16/16 (100%) samples for MCV. These results suggest that close mobile phone exposure may be an unappreciated and possibly underestimated cause of preanalytical bias in RBC testing.

  6. Preanalytical stability of maternal serum markers hCGβ and PAPP-A.

    PubMed

    Veyrat, Béatrice; Tosetti, François; Morin, Jean-François; Moineau, Marie-Pierre; Piedimonte, Andrée; Clément, Patrice; Dreux, Sophie; Muller, Françoise

    2017-04-01

    Down syndrome maternal serum marker screening is based on a risk calculation including the free β - human chorionic gonadotropin (hCGβ) and pregnancy-associated placenta protein type A (PAPP-A). The aim of this study was to define the pre-analytical conditions of stability of these markers both in whole blood at 15-25 ̊C and, after centrifugation, in serum at 4-8 ̊C. 158 patients were included in the study. Two automated workstations were used for assays, Cobas 8000e602, Roche Diagnostics (58 patients tested) and DELFIAXpress, PerkinElmer (100 patients tested). The stability of markers was studied in whole blood (15-25 ̊C) 2, 4, 6 and 8 hours after sampling and in serum stored after centrifugation at 4-8 ̊C at 24, 72 and 120 hours. Variations were defined by (C T - C 2 )/C 2 , C 2 being the marker concentration at 2 hours and C T the concentration at time T. In whole blood kept for 8 hours at 15-25 ̊C, hCGβ increased by a mean 2.4%, whereas the mean increase of PAPP-A was < 1%. In the serum kept for 5 days at 4-8̊C, the mean increase of hCGβ was 4.2%, with no change in PAPP-A. The impact of these variations on risk calculation is low. In conclusion, maternal serum can be store 8 hours at 15-25̊C in whole blood and 5 days at 4-8̊C after centrifugation and serum separation for Down syndrome maternal serum screening.

  7. Trace element reference values in tissues from inhabitants of the European Community. III. The control of preanalytical factors in the biomonitoring of trace elements in biological fluids.

    PubMed

    Minoia, C; Pietra, R; Sabbioni, E; Ronchi, A; Gatti, A; Cavalleri, A; Manzo, L

    1992-06-09

    In the context of a programme concerning the determination of trace elements in body fluids and tissues to establish trace element reference values, research has been undertaken on the control of preanalytical factors in order to develop sufficiently accurate and precise guidelines to be applied in routine work by using techniques such as graphite furnace atomic absorption spectroscopy (GFAAS). Aspects investigated are related to the risk of contamination during blood collection and the use of anticoagulants; the risk of losses during storage and freeze-drying as well as the possible risk of contamination arising from trace elements in airborne particulates of the laboratory environment. For the analysis of Al, Ba, Cd, Co, Cr, Mn, Mo, Ni, Sb, W, V and Zn in blood, Teflon cannula is the method of choice. The anticoagulants do not introduce disturbing contaminations of Rb, Se, Zn, while contaminations were observed for Co, Cr, Mn. Radiotracers in 'metabolized form' (radiolabelled rat or rabbit tissues from animals administered with radioisotopes) show that samples stored for 1 month at -20 degrees C have no significant trace metal losses. Strict ambient air quality standard has to be respected (continuous monitoring) due to the possibility of element contaminations inside the laboratory. The use of matrix modifiers could represent a toxicological risk to the operators. Critical factors should be considered ('metal sheets') for each element in each matrix. For instance 27 factors for Cr in serum have been suggested.

  8. [Biochemical markers of bone remodeling: pre-analytical variations and guidelines for their use. SFBC (Société Française de Biologie Clinique) Work Group. Biochemical markers of bone remodeling].

    PubMed

    Garnero, P; Bianchi, F; Carlier, M C; Genty, V; Jacob, N; Kamel, S; Kindermans, C; Plouvier, E; Pressac, M; Souberbielle, J C

    2000-01-01

    Biochemical markers of bone turnover have been developed over the past 20 years that are more specific for bone tissue than conventional ones such as total alkaline phosphatase and urinary hydroxyproline. They have been widely used in clinical research and in clinical trials of new therapies as secondary end points of treatment efficacy. Most of the interest has been devoted to their use in postmenopausal osteoporosis, a condition characterized by subtle modifications of bone metabolism that cannot be detected readily by conventional markers of bone turnover. Although several recent studies have suggested that biochemical markers may be used for the management of the individual patient in routine clinical practice, this has not been clearly defined and is a matter of debate. Because of the crucial importance to clarify this issue, the Société Francaise de Biologie Clinique prompted an expert committee to summarize the available data and to make recommendations. The following paper includes a review on the biochemical and analytical aspects of the markers of bone formation and resorption and on the sources of variability such as sex, age, menstrual cycle, pregnancy and lactation, physical activity, seasonal variation and effects of diseases and treatments. We will also describe the effects of pre-analytical factors on the measurements of the different markers. Finally based on that review, we will make practical recommendations for the use of these markers in order to minimize the variability of the measurements and improve the clinical interpretation of the data.

  9. Preanalytical blood sample workup for cell-free DNA analysis using Droplet Digital PCR for future molecular cancer diagnostics.

    PubMed

    van Ginkel, Joost H; van den Broek, Daan A; van Kuik, Joyce; Linders, Dorothé; de Weger, Roel; Willems, Stefan M; Huibers, Manon M H

    2017-10-01

    In current molecular cancer diagnostics, using blood samples of cancer patients for the detection of genetic alterations in plasma (cell-free) circulating tumor DNA (ctDNA) is an emerging practice. Since ctDNA levels in blood are low, highly sensitive Droplet Digital PCR (ddPCR) can be used for detecting rare mutational targets. In order to perform ddPCR on blood samples, a standardized procedure for processing and analyzing blood samples is necessary to facilitate implementation into clinical practice. Therefore, we assessed the technical sample workup procedure for ddPCR on blood plasma samples. Blood samples from healthy individuals, as well as lung cancer patients were analyzed. We compared different methods and protocols for sample collection, storage, centrifugation, isolation, and quantification. Cell-free DNA (cfDNA) concentrations of several wild-type targets and BRAF and EGFR-mutant ctDNA concentrations quantified by ddPCR were primary outcome measurements. Highest cfDNA concentrations were measured in blood collected in serum tubes. No significant differences in cfDNA concentrations were detected between various time points of up to 24 h until centrifugation. Highest cfDNA concentrations were detected after DNA isolation with the Quick cfDNA Serum & Plasma Kit, while plasma isolation using the QIAamp Circulating Nucleic Acid Kit yielded the most consistent results. DdPCR results on cfDNA are highly dependent on multiple factors during preanalytical sample workup, which need to be addressed during the development of this diagnostic tool for cancer diagnostics in the future. © 2017 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  10. The cobas p 630 instrument: a dedicated pre-analytic solution to optimize COBAS® AmpliPrep/COBAS® TaqMan® system workflow and turn-around-time.

    PubMed

    Vallefuoco, L; Sorrentino, R; Spalletti Cernia, D; Colucci, G; Portella, G

    2012-12-01

    The cobas p 630, a fully automated pre-analytical instrument for primary tube handling recently introduced to complete the Cobas(®) TaqMan systems portfolio, was evaluated in conjunction with: the COBAS(®) AmpliPrep/COBAS(®) TaqMan HBV Test, v2.0, COBAS(®) AmpliPrep/COBAS(®) TaqMan HCV Test, v1.0 and COBAS(®) AmpliPrep/COBAS(®) TaqMan HIV Test, v2.0. The instrument performance in transferring samples from primary to secondary tubes, its impact in improving COBAS(®) AmpliPrep/COBAS(®) TaqMan workflow and hands-on reduction and the risk of possible cross-contamination were assessed. Samples from 42 HBsAg positive, 42 HCV and 42 HIV antibody (Ab) positive patients as well as 21 healthy blood donors were processed with or without automated primary tubes. HIV, HCV and HBsAg positive samples showed a correlation index of 0.999, 0.987 and of 0.994, respectively. To assess for cross-contamination, high titer HBV DNA positive samples, HCV RNA and HIV RNA positive samples were distributed in the cobas p 630 in alternate tube positions, adjacent to negative control samples within the same rack. None of the healthy donor samples showed any reactivity. Based on these results, the cobas p 630 can improve workflow and sample tracing in laboratories performing molecular tests, and reduce turnaround time, errors, and risks. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. External quality assessment of urine particle identification: a Northern European experience.

    PubMed

    Kouri, Timo T; Makkonen, Pirjo

    2015-11-01

    External quality assessment (EQA) schemes for urinalysis have been provided by Labquality Ltd, the publicly owned EQA service provider in Finland, since the 1980s. In 2014, the scheme on urine particle identification had 329 participating laboratories, out of which 60% from 19 countries were outside Finland. Each of the four annual web-based rounds were distributed with four Sternheimer-stained images from a single patient sample, as viewed both by bright-field and phase-contrast optics. Participants reported classified categories either at the basic or at the advanced level. Participating laboratories received assessment of their analytical performance as compared to their peers, including reflections from clinical data and preanalytical detail of the specimen. In general, reporting of basic urine particles succeeded in the eight schemes during the years 2013-2014 as follows: red blood cells 82%-92%, white blood cells 82%-97%, squamous epithelial cells 92%-98%, casts 84%-94%, and small epithelial cells 73%-83% (minimum and maximum of expected or accepted reports). This basic level of differentiation is used in routine laboratory reports, or as verification of results produced by automated instruments. Considerable effort is needed to standardise national procedures and reporting formats, in order to improve the shown figures internationally. Future technologies may help to alleviate limitations created by single digital images. Despite improvements, degenerating cells and casts always exhibit intermediate forms creating disputable classifications. That is why assessment of performance should encompass justified acceptable categories into the assessed outcomes. Preanalytical and clinical detail provide essential added value to morphological findings.

  12. Laboratory testing of extravascular body fluids in Croatia: a survey of the Working group for extravascular body fluids of the Croatian Society of Medical Biochemistry and Laboratory Medicine

    PubMed Central

    Kopcinovic, Lara Milevoj; Vogrinc, Zeljka; Kocijan, Irena; Culej, Jelena; Aralica, Merica; Jokic, Anja; Antoncic, Dragana; Bozovic, Marija

    2016-01-01

    Introduction We hypothesized that extravascular body fluid (EBF) analysis in Croatia is not harmonized and aimed to investigate preanalytical, analytical and postanalytical procedures used in EBF analysis in order to identify key aspects that should be addressed in future harmonization attempts. Materials and methods An anonymous online survey created to explore laboratory testing of EBF was sent to secondary, tertiary and private health care Medical Biochemistry Laboratories (MBLs) in Croatia. Statements were designed to address preanalytical, analytical and postanalytical procedures of cerebrospinal, pleural, peritoneal (ascites), pericardial, seminal, synovial, amniotic fluid and sweat. Participants were asked to declare the strength of agreement with proposed statements using a Likert scale. Mean scores for corresponding separate statements divided according to health care setting were calculated and compared. Results The survey response rate was 0.64 (58 / 90). None of the participating private MBLs declared to analyse EBF. We report a mean score of 3.45 obtained for all statements evaluated. Deviations from desirable procedures were demonstrated in all EBF testing phases. Minor differences in procedures used for EBF analysis comparing secondary and tertiary health care MBLs were found. The lowest scores were obtained for statements regarding quality control procedures in EBF analysis, participation in proficiency testing programmes and provision of interpretative comments on EBF’s test reports. Conclusions Although good laboratory EBF practice is present in Croatia, procedures for EBF analysis should be further harmonized to improve the quality of EBF testing and patient safety. PMID:27812307

  13. Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories.

    PubMed

    Wallin, Olof; Söderberg, Johan; Van Guelpen, Bethany; Stenlund, Hans; Grankvist, Kjell; Brulin, Christine

    2010-09-01

    Scand J Caring Sci; 2010; 24; 581-591 
 Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories   Most errors in venous blood testing result from human mistakes occurring before the sample reach the laboratory.   To survey venous blood sampling (VBS) practices in hospital wards and to compare practices with hospital laboratories.   Staff in two hospitals (all wards) and two hospital laboratories (314 respondents, response rate 94%), completed a questionnaire addressing issues relevant to the collection of venous blood samples for clinical chemistry testing.   The findings suggest that instructions for patient identification and the collection of venous blood samples were not always followed. For example, 79% of the respondents reported the undesirable practice (UDP) of not always using wristbands for patient identification. Similarly, 87% of the respondents noted the UDP of removing venous stasis after the sampling is finished. Compared with the ward staff, a significantly higher proportion of the laboratory staff reported desirable practices regarding the collection of venous blood samples. Neither education nor the existence of established sampling routines was clearly associated with VBS practices among the ward staff.   The results of this study, the first of its kind, suggest that a clinically important risk of error is associated with VBS in the surveyed wards. Most important is the risk of misidentification of patients. Quality improvement of blood sample collection is clearly needed, particularly in hospital wards. © 2009 The Authors. Journal compilation © 2009 Nordic College of Caring Science.

  14. Bayesian Probability Theory

    NASA Astrophysics Data System (ADS)

    von der Linden, Wolfgang; Dose, Volker; von Toussaint, Udo

    2014-06-01

    Preface; Part I. Introduction: 1. The meaning of probability; 2. Basic definitions; 3. Bayesian inference; 4. Combinatrics; 5. Random walks; 6. Limit theorems; 7. Continuous distributions; 8. The central limit theorem; 9. Poisson processes and waiting times; Part II. Assigning Probabilities: 10. Transformation invariance; 11. Maximum entropy; 12. Qualified maximum entropy; 13. Global smoothness; Part III. Parameter Estimation: 14. Bayesian parameter estimation; 15. Frequentist parameter estimation; 16. The Cramer-Rao inequality; Part IV. Testing Hypotheses: 17. The Bayesian way; 18. The frequentist way; 19. Sampling distributions; 20. Bayesian vs frequentist hypothesis tests; Part V. Real World Applications: 21. Regression; 22. Inconsistent data; 23. Unrecognized signal contributions; 24. Change point problems; 25. Function estimation; 26. Integral equations; 27. Model selection; 28. Bayesian experimental design; Part VI. Probabilistic Numerical Techniques: 29. Numerical integration; 30. Monte Carlo methods; 31. Nested sampling; Appendixes; References; Index.

  15. Need for new sensors to map lithologic units

    USGS Publications Warehouse

    Rowan, Lawrence C.; Barringer, Anthony R.

    1980-01-01

    One of the most important contributions that remote sensing can make to mineral energy explorations to provide data from satellites to augment regional geological mapping. Geologic maps, which show information on the subsurface, are the main basis for formulating models of resource genesis that guide exploration. However, conventional compilation procedures are time-consuming and therefore often slow the pace of exploration, especially in large, inaccessible areas. Landsat Multispectral Scanner (MSS) images have been applied to a wide variety of specific geological problems, including discrimination of lithologic and delineation of previously unrecognized tectonic features. However, these lithologic distinctions are based on brightness, spectral reflectance, and, less commonly, the morphology of the unit, which in the wavelength region of MSS images are only rarely diagnostic of specific mineralogical content. Limonite is the only lithological material that can be identified be analyzing MSS spectral radiance.

  16. Improved method for HPLC analysis of polyamines, agmatine and aromatic monoamines in plant tissue

    NASA Technical Reports Server (NTRS)

    Slocum, R. D.; Flores, H. E.; Galston, A. W.; Weinstein, L. H.

    1989-01-01

    The high performance liquid chromatographic (HPLC) method of Flores and Galston (1982 Plant Physiol 69: 701) for the separation and quantitation of benzoylated polyamines in plant tissues has been widely adopted by other workers. However, due to previously unrecognized problems associated with the derivatization of agmatine, this important intermediate in plant polyamine metabolism cannot be quantitated using this method. Also, two polyamines, putrescine and diaminopropane, also are not well resolved using this method. A simple modification of the original HPLC procedure greatly improves the separation and quantitation of these amines, and further allows the simulation analysis of phenethylamine and tyramine, which are major monoamine constituents of tobacco and other plant tissues. We have used this modified HPLC method to characterize amine titers in suspension cultured carrot (Daucas carota L.) cells and tobacco (Nicotiana tabacum L.) leaf tissues.

  17. Success of torsional correction surgery after failed surgeries for patellofemoral pain and instability.

    PubMed

    Stevens, Peter M; Gililland, Jeremy M; Anderson, Lucas A; Mickelson, Jennifer B; Nielson, Jenifer; Klatt, Joshua W

    2014-04-01

    Torsional deformities of the femur and/or tibia often go unrecognized in adolescents and adults who present with anterior knee pain, and patellar maltracking or instability. While open and arthroscopic surgical techniques have evolved to address these problems, unrecognized torsion may compromise the outcomes of these procedures. We collected a group of 16 consecutive patients (23 knees), with mean age of 17, who had undergone knee surgery before torsion was recognized and subsequently treated by means of rotational osteotomy of the tibia and/or femur. By follow-up questionnaire, we sought to determine the role of rotational correction at mean 59-month follow-up. We reasoned that, by correcting torsional alignment, we might be able to optimize long-term outcomes and avert repeated knee surgery. Knee pain was significantly improved after torsional treatment (mean 8.6 pre-op vs. 3.3 post-op, p < 0.001), while 70 % of patients did have some continued knee pain postoperatively. Only 43 % of patients had continued patellar instability, and 57 % could trust their knee after surgery. Activity level remained the same or increased in 78 % of patients after torsional treatment. Excluding planned rod removal, subsequent knee surgery for continued anterior knee pain was undertaken on only 3 knees in 2 patients. We believe that malrotation of the lower limb not only raises the propensity for anterior knee symptoms, but is also a under-recognized etiology in the failure of surgeries for anterior knee pain and patellar instability. Addressing rotational abnormalities in the index surgery yields better clinical outcomes than osteotomies performed after other prior knee surgeries.

  18. Prevention of unrecognized joint penetration during internal fixation of hip fractures: a geometric model based on Steinmetz Solid.

    PubMed

    Mao, Yujiang; Song, Jie; Wei, Jie; Wang, Manyi

    2010-01-01

    Unrecognized joint penetration (UJP) by screw penetration through the articular surface undetectable on routine anteroposterior (AP) and lateral radiographs can cause serious complications. We have developed a geometric model to analyze UJP, and methods for the prevention of the problem. A Steinmetz Solid (SS) is the overlapping portion between two identical, vertically intersecting cylinders. The AP and lateral radiographs of a femoral head (simplified as a sphere) are projections of two cylinder-shaped images. A screw that appears to be within the femoral head in fact only lies within the cylinder. A screw apparently within the femoral head on both AP and lateral images is only confined to the SS generated by two cylinders, but not necessarily confined to the femoral head itself. We have therefore analyzed UJP using a geometric model based on SS. The geometric basis of UJP lies in the fact that the SS is larger than the sphere (femoral head) with a volume ratio of 4: π. The theoretical risk of UJP for any screw therefore can be as high as 21.5% ((4-π)/4). In reality, screws are always carefully placed to ensure a distance between the screw's tip and the edge of femoral head (tip-to-edge distance, or TED). This TED effectively lowers the risk of UJP by reducing the size of the screw-confining SS. When the SS entirely fits into (internally tangential to) the femoral head, the risk of UJP approaches zero. A TED fulfilling this requirement can be regarded as safe (approximately 0.29 x femoral head radius). With a femoral head diameter of 5 cm, the safe TED is approximately 7 mm.

  19. How good are we at managing acute kidney injury in hospital?

    PubMed

    Meran, Soma; Wonnacott, Alexa; Amphlett, Bethan; Phillips, Aled

    2014-04-01

    Acute kidney injury (AKI) is a common clinical problem associated with adverse outcomes. This study identifies the incidence of AKI in two UK district general hospitals' without on-site renal services and assesses AKI management and level of nephrologist input. The AKIN classification was used to identify 1020 AKI patients over 6 months. Data were collated on patient demographics, AKI management and referral to nephrology and intensive care services. Short/long-term renal outcomes were investigated. Patients were followed up for 14 months post-discharge. Incidence of hospital-based AKI was 6.4%. Mean patient age was 73 years. There was 28.1% acute in-hospital mortality with a further 21.6% 14-month mortality. Only 8.3% of patients were referred to nephrology services for in-hospital review, and only 8.1% had outpatient nephrology follow-up. Compliance with the AKI National Confidential Enquiry into Patient Outcomes and Deaths (NCEPOD) recommendations was poor with 32.8% of patients having renal imaging and 15% of patients having acid-base status assessed. NCEPOD compliance improved with nephrology input. Patients referred to nephrology were likely to be younger with pre-existing CKD and severe AKI. 10.5% of AKI episodes were unrecognized. Forty percent of those with unrecognized AKI, (compared with 15% of recognized AKI) developed de novo or progression of pre-existing CKD. AKI in DGHs is mostly managed without nephrology input. There are significant shortcomings in AKI recognition and management in this setting. This is associated with poor mortality and long-term CKD. This study supports a need to improve the teaching and training of front-line medical staff in identifying AKI. Additionally, implementation of AKI e-alert systems may encourage early recognition and provide a prompt for renal referral.

  20. Folklore and traditional ecological knowledge of geckos in Southern Portugal: implications for conservation and science.

    PubMed

    Ceríaco, Luis M P; Marques, Mariana P; Madeira, Natália C; Vila-Viçosa, Carlos M; Mendes, Paula

    2011-09-05

    Traditional Ecological Knowledge (TEK) and folklore are repositories of large amounts of information about the natural world. Ideas, perceptions and empirical data held by human communities regarding local species are important sources which enable new scientific discoveries to be made, as well as offering the potential to solve a number of conservation problems. We documented the gecko-related folklore and TEK of the people of southern Portugal, with the particular aim of understanding the main ideas relating to gecko biology and ecology. Our results suggest that local knowledge of gecko ecology and biology is both accurate and relevant. As a result of information provided by local inhabitants, knowledge of the current geographic distribution of Hemidactylus turcicus was expanded, with its presence reported in nine new locations. It was also discovered that locals still have some misconceptions of geckos as poisonous and carriers of dermatological diseases. The presence of these ideas has led the population to a fear of and aversion to geckos, resulting in direct persecution being one of the major conservation problems facing these animals. It is essential, from both a scientific and conservationist perspective, to understand the knowledge and perceptions that people have towards the animals, since, only then, may hitherto unrecognized pertinent information and conservation problems be detected and resolved.

  1. Folklore and traditional ecological knowledge of geckos in Southern Portugal: implications for conservation and science

    PubMed Central

    2011-01-01

    Traditional Ecological Knowledge (TEK) and folklore are repositories of large amounts of information about the natural world. Ideas, perceptions and empirical data held by human communities regarding local species are important sources which enable new scientific discoveries to be made, as well as offering the potential to solve a number of conservation problems. We documented the gecko-related folklore and TEK of the people of southern Portugal, with the particular aim of understanding the main ideas relating to gecko biology and ecology. Our results suggest that local knowledge of gecko ecology and biology is both accurate and relevant. As a result of information provided by local inhabitants, knowledge of the current geographic distribution of Hemidactylus turcicus was expanded, with its presence reported in nine new locations. It was also discovered that locals still have some misconceptions of geckos as poisonous and carriers of dermatological diseases. The presence of these ideas has led the population to a fear of and aversion to geckos, resulting in direct persecution being one of the major conservation problems facing these animals. It is essential, from both a scientific and conservationist perspective, to understand the knowledge and perceptions that people have towards the animals, since, only then, may hitherto unrecognized pertinent information and conservation problems be detected and resolved. PMID:21892925

  2. Microplates in liquid chromatography--new solution in clinical research? A review.

    PubMed

    Krcmova, Lenka; Solichova, Dagmar; Solich, Petr

    2013-10-15

    Microplates are routinely used in Radio- or Immuno-assays. Recently, microplates have found use not only in analytical but also in the pre-analytical phase in bioanalyses (sample storage, sample preparation). New connection of this technology to liquid chromatography could be economical, fast and simple solution for many routine laboratories handling large sequences of biological samples. This review summarises the application of microplates in bioanalytical laboratories. Different types of sorbents, materials and shapes of microplates are discussed, and the main advantages and disadvantages of microplates used in clinical research are presented. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. [Management of pre-analytical nonconformities].

    PubMed

    Berkane, Z; Dhondt, J L; Drouillard, I; Flourié, F; Giannoli, J M; Houlbert, C; Surgat, P; Szymanowicz, A

    2010-12-01

    The main nonconformities enumerated to facilitate consensual codification. In each case, an action is defined: refusal to realize the examination with request of a new sample, request of information or correction, results cancellation, nurse or physician information. A traceability of the curative, corrective and preventive actions is needed. Then, methodology and indicators are proposed to assess nonconformity and to follow the quality improvements. The laboratory information system can be used instead of dedicated software. Tools for the follow-up of nonconformities scores are proposed. Finally, we propose an organization and some tools allowing the management and control of the nonconformities occurring during the pre-examination phase.

  4. [Blood sampling using "dried blood spot": a clinical biology revolution underway?].

    PubMed

    Hirtz, Christophe; Lehmann, Sylvain

    2015-01-01

    Blood testing using the dried blood spot (DBS) is used since the 1960s in clinical analysis, mainly within the framework of the neonatal screening (Guthrie test). Since then numerous analytes such as nucleic acids, small molecules or lipids, were successfully measured on the DBS. While this pre-analytical method represents an interesting alternative to classic blood sampling, its use in routine is still limited. We review here the different clinical applications of the blood sampling on DBS and estimate its future place, supported by the new methods of analysis as the LC-MS mass spectrometry.

  5. [The taking and transport of biological samples].

    PubMed

    Kerwat, Klaus; Kerwat, Martina; Eberhart, Leopold; Wulf, Hinnerk

    2011-05-01

    The results of microbiological tests are the foundation for a targetted therapy and the basis for monitoring infections. The quality of each and every laboratory finding depends not only on an error-free analytical process. The pre-analysis handling procedures are of particular importance. They encompass all factors and influences prior to the actual analysis. These include the correct timepoint for sample taking, the packaging and the rapid transport of the material to be investigated. Errors in the pre-analytical processing are the most frequent reasons for inappropriate findings. © Georg Thieme Verlag Stuttgart · New York.

  6. Unrecognized heart failure and chronic obstructive pulmonary disease (COPD) in frail elderly detected through a near-home targeted screening strategy.

    PubMed

    van Mourik, Yvonne; Bertens, Loes C M; Cramer, Maarten J M; Lammers, Jan-Willem J; Reitsma, Johannes B; Moons, Karel G M; Hoes, Arno W; Rutten, Frans H

    2014-01-01

    Reduced exercise tolerance and dyspnea are common in older people, and heart failure (HF) and chronic obstructive pulmonary disease (COPD) are the main causes. We want to determine the prevalence of previously unrecognized HF, COPD, and other chronic diseases in frail older people using a near-home targeted screening strategy. Community-dwelling frail persons aged ≥65 years underwent a 2-step screening strategy. First, they received a questionnaire inquiring about dyspnea and exercise tolerance. Those with exercise intolerance and/or dyspnea were invited to visit their primary care physician's office for a screening program, including medical history taking, physical examination, blood tests, electrocardiography, spirometry, and echocardiography. The final diagnosis of every patient was determined by a panel consisting of 3 physicians. Of the 570 elderly who filled out the questionnaire, 395 (69%) had reduced exercise tolerance or dyspnea. Of these, 389 underwent the screening program: 127 (33.5%, 95% confidence interval, 28.9-38.4%) were newly diagnosed with HF (mainly HF with a preserved ejection fraction [23.5%]), and previously unrecognized COPD was detected in 16.8% (95% confidence interval, 13.4-20.9%). In total, 165 patients (43.9%) received a new diagnosis of either HF, COPD, or both. Other new diagnoses (in 32.7% of the screening program patients) included atrial fibrillation (1.8%), valvular disease (21.4%), (persisting) asthma (3.1%), anemia (12.7%), and thyroid disease (0.6%). No clear explanation for the complaints of 47 patients (12.2%) was found using our strategy. Unrecognized chronic diseases might be detected in community-dwelling frail elderly using a near-home screening strategy that is simple to implement. It remains to be proven, however, whether optimizing treatment of the newly detected diagnoses in this fragile population with multimorbidities and polypharmacy improves quality of life and reduces morbidity and mortality. © Copyright 2014 by the American Board of Family Medicine.

  7. Lobectomy is a more Cost-Effective Option than Total Thyroidectomy for 1 to 4 cm Papillary Thyroid Carcinoma that do not Possess Clinically Recognizable High-Risk Features.

    PubMed

    Lang, Brian Hung-Hin; Wong, Carlos K H

    2016-10-01

    Although lobectomy is a viable alternative to total thyroidectomy (TT) in low-risk 1 to 4 cm papillary thyroid carcinoma (PTC), lobectomy is associated with higher locoregional recurrence risk and need for completion TT upon discovery of a previously unrecognized histologic high-risk feature (HRF). The present study evaluated long-term cost-effectiveness between lobectomy and TT. Our base case was a hypothetical female cohort aged 40 years with a low-risk 2.5 cm PTC. A Markov decision tree model was constructed to compare cost-effectiveness between lobectomy and TT after 25 years. Patients with an unrecognized HRF (including aggressive histology, microscopic extrathyroidal extension, lymphovascular invasion, positive resection margin, nodal metastasis >5 mm, and multifocality) underwent completion TT after lobectomy. Outcome probabilities, utilities, and costs were estimated from the literature. The threshold for cost-effectiveness was set at US$50,000/quality-adjusted life-year (QALY). Sensitivity and threshold analyses were used to examine model uncertainty. After 25 years, each patient who underwent lobectomy instead of TT cost an extra US$772.08 but gained an additional 0.300 QALY. The incremental cost-effectiveness ratio was US$2577.65/QALY. In the sensitivity analysis, the lobectomy arm began to become cost-effective only after 3 years. Despite varying the reported prevalence of clinically unrecognized HRFs, complication from surgical procedures, annualized recurrence rates, unit cost of surgical procedure or complication, and utility score, lobectomy remained more cost-effective than TT. Despite the higher locoregional recurrence risk and having almost half of the patients undergoing completion TT after lobectomy upon discovery of a previously unrecognized HRF, initial lobectomy was a more cost-effective long-term option than initial TT for 1 to 4 cm PTCs without clinically recognized HRFs.

  8. Burden of Systolic and Diastolic Left Ventricular Dysfunction among Hispanics in the United States: Insights from the Echocardiographic Study of Latinos (ECHO-SOL)

    PubMed Central

    Mehta, Hardik; Armstrong, Anderson; Swett, Katrina; Shah, Sanjiv J.; Allison, Matthew A.; Hurwitz, Barry; Bangdiwala, Shrikant; Dadhania, Rupal; Kitzman, Dalane W.; Arguelles, William; Lima, Joao; Youngblood, Marston; Schneiderman, Neil; Daviglus, Martha L.; Spevack, Daniel; Talavera, Greg A.; Raisinghani, Ajit; Kaplan, Robert; Rodriguez, Carlos J.

    2016-01-01

    Background Population-based estimates of cardiac dysfunction and clinical heart failure (HF) remain undefined among Hispanics/Latino adults. Methods and Results Participants of Hispanic/Latino origin across the US, aged 45–74 years were enrolled into the Echocardiographic Study of Latinos (ECHO-SOL) and underwent a comprehensive echocardiography exam to define left ventricular systolic dysfunction (LVSD) and left ventricular diastolic dysfunction (LVDD). Clinical HF was defined according to self-report; and those with cardiac dysfunction but without clinical HF were characterized as having subclinical or unrecognized cardiac dysfunction. Of 1,818 ECHO-SOL participants (mean age 56.4 years; 42.6% male) , 49.7% had LVSD and/or LVDD. LVSD prevalence was 3.6%, while LVDD was detected in 50.3%. Participants with LVSD were more likely to be males and current smokers (all p<0.05). Female sex, hypertension, diabetes, higher body-mass index and renal dysfunction were more common among those with LVDD (all p<0.05). In age-sex adjusted models, individuals of Central American and Cuban backgrounds were almost two-fold more likely to have LVDD compared to those of Mexican backgrounds. Prevalence of clinical HF with LVSD (HF with reduced EF) was 7.3%; prevalence of clinical HF with LVDD (HF with preserved EF) was 3.6%. 96.1% of the cardiac dysfunction seen was subclinical or unrecognized. Compared to those with clinical cardiac dysfunction, prevalent coronary heart disease was the only factor independently associated with subclinical or unrecognized cardiac dysfunction (odds ratio: 0.1; 95% confidence interval: 0.1–0.4). Conclusions Among Hispanics/Latinos, most cardiac dysfunction is subclinical or unrecognized, with a high prevalence of diastolic dysfunction. This identifies a high-risk population for the development of clinical HF. PMID:27048764

  9. Using mHealth technologies to improve the identification of behavioral health problems in urban primary care settings.

    PubMed

    Staeheli, Martha; Aseltine, Robert H; Schilling, Elizabeth; Anderson, Daren; Gould, Bruce

    2017-01-01

    Behavioral health disorders remain under recognized and under diagnosed among urban primary care patients. Screening patients for such problems is widely recommended, yet is challenging to do in a brief primary care encounter, particularly for this socially and medically complex patient population. In 2013, intervention patients at an urban Connecticut primary clinic were screened for post-traumatic stress disorder, depression, and risky drinking (n = 146) using an electronic tablet-based screening tool. Screening data were compared to electronic health record data from control patients (n = 129) to assess differences in the prevalence of behavioral health problems, rates of follow-up care, and the rate of newly identified cases in the intervention group. Results from logistic regressions indicated that both groups had similar rates of disorder at baseline. Patients in the intervention group were five times more likely to be identified with depression (p < 0.05). Post-traumatic stress disorder was virtually unrecognized among controls but was observed in 23% of the intervention group (p < 0.001). The vast majority of behavioral health problems identified in the intervention group were new cases. Follow-up rates were significantly higher in the intervention group relative to controls, but were low overall. This tablet-based electronic screening tool identified significantly higher rates of behavioral health disorders than have been previously reported for this patient population. Electronic risk screening using patient-reported outcome measures offers an efficient approach to improving the identification of behavioral health problems and improving rates of follow-up care.

  10. MULTIMODAL IMAGING OF SYPHILITIC MULTIFOCAL RETINITIS.

    PubMed

    Curi, Andre L; Sarraf, David; Cunningham, Emmett T

    2015-01-01

    To describe multimodal imaging of syphilitic multifocal retinitis. Observational case series. Two patients developed multifocal retinitis after treatment of unrecognized syphilitic uveitis with systemic corticosteroids in the absence of appropriate antibiotic therapy. Multimodal imaging localized the foci of retinitis within the retina in contrast to superficial retinal precipitates that accumulate on the surface of the retina in eyes with untreated syphilitic uveitis. Although the retinitis resolved after treatment with systemic penicillin in both cases, vision remained poor in the patient with multifocal retinitis involving the macula. Treatment of unrecognized syphilitic uveitis with corticosteroids in the absence of antitreponemal treatment can lead to the development of multifocal retinitis. Multimodal imaging, and optical coherence tomography in particular, can be used to distinguish multifocal retinitis from superficial retinal precipitates or accumulations.

  11. Extra-articular hip impingement: a narrative review of the literature

    PubMed Central

    Cheatham, Scott W.

    2016-01-01

    There is growing subgroup of patients with poor outcomes after hip arthroscopy for intra-articular pathology suggesting unrecognized cause(s) of impingement may exist. Extra-articular hip impingement (EHI) is an emerging group of conditions that have been associated with intra-articular causes of impingement and may be an unrecognized source of pain. EHI is caused by abnormal contact between the extra-articular regions of the proximal femur and pelvis. This review discusses the most common forms for EHI including: central iliopsoas impingement, subspine impingement, ischiofemoral impingement, and greater trochanteric-pelvic impingement. The clinical presentation of each pathology will be discussed since EHI conditions share similar clinical features as the intra-articular pathology but also contain some unique characteristics. PMID:27069266

  12. Apparent mineralcorticoid excess syndrome, an often forgotten or unrecognized cause of hypokalemia and hypertension: case report and appraisal of the pathophysiology.

    PubMed

    Bisogni, Valeria; Rossi, Gian Paolo; Calò, Lorenzo A

    2014-06-01

    The glicyrrhizic acid, contained in licorice, has a mineralcorticoid-like effect. Chronic excess intake of licorice induces the rare syndrome of "apparent mineralcorticoid excess", due to the inhibitory effect of glicyrrhizic acid on 11 β-hydroxysteroid dehydrogenase type 2 determining clinical/biochemical manifestations as resistant hypertension, metabolic alkalosis and severe hypokalemia. We report a typical clinical case of licorice abuse to emphasize the importance of a detailed anamnesis, which is essential for the diagnosis, avoid unnecessary and expensive investigations, and reduce the duration of hospitalization. We also provide an appraisal of the pathophysiology of "apparent mineralcorticoid excess" syndrome, still an often forgotten or unrecognized cause of hypokalemia and hypertension.

  13. Hypertension in pediatric patients with chronic kidney disease: management challenges.

    PubMed

    Gallibois, Claire M; Jawa, Natasha A; Noone, Damien G

    2017-01-01

    In contrast to adults where hypertension is a leading cause of chronic kidney disease, in pediatrics, hypertension is predominantly a sequela, however, an important one that, like in adults, is likely associated with a more rapid decline in kidney function or progression of chronic kidney disease to end stage. There is a significant issue with unrecognized, or masked, hypertension in childhood chronic kidney disease. Recent evidence and, therefore, guidelines now suggest targeting a blood pressure of <50th percentile for age, sex, and height in children with proteinuria and chronic kidney disease. This often cannot be achieved by monotherapy and additional agents need to be added. Blockade of the renin angiotensin aldosterone system represents the mainstay of therapy, although often limited by the side effect of hyperkalemia. The addition of a diuretic, at least in the earlier stages of chronic kidney disease, might help mitigate this problem.

  14. Sport-related concussions in adolescent athletes: a critical public health problem for which prevention remains an elusive goal

    PubMed Central

    Fidrocki, Diana; Parachuri, Venu

    2017-01-01

    Sport-related concussions in young athletes are common, generally under reported and often unrecognized. Preventive strategies include education, modification of sport rules, use of equipment such as headgears, face masks and mouth guards, and neck muscle training. Evidence is limited to support effectiveness of these preventive measures with the exception of rule modification in some sports. In the United States, laws have been enacted that require medical evaluation and clearance prior to return to play; however, evidence thus far does not show that laws have been effective in reducing the incidence of concussions in sport. More research is needed in all areas of preventive measures. Sports participation is a complex personal decision on the part of the adolescent and his or her family. They should be provided with all information on inherent risks so that they can make an informed decision. PMID:28795000

  15. Pleural innate response activator B cells protect against pneumonia via a GM-CSF-IgM axis

    PubMed Central

    Chousterman, Benjamin G.; Hilgendorf, Ingo; Robbins, Clinton S.; Theurl, Igor; Gerhardt, Louisa M.S.; Iwamoto, Yoshiko; Quach, Tam D.; Ali, Muhammad; Chen, John W.; Rothstein, Thomas L.; Nahrendorf, Matthias; Weissleder, Ralph

    2014-01-01

    Pneumonia is a major cause of mortality worldwide and a serious problem in critical care medicine, but the immunophysiological processes that confer either protection or morbidity are not completely understood. We show that in response to lung infection, B1a B cells migrate from the pleural space to the lung parenchyma to secrete polyreactive emergency immunoglobulin M (IgM). The process requires innate response activator (IRA) B cells, a transitional B1a-derived inflammatory subset which controls IgM production via autocrine granulocyte/macrophage colony-stimulating factor (GM-CSF) signaling. The strategic location of these cells, coupled with the capacity to produce GM-CSF–dependent IgM, ensures effective early frontline defense against bacteria invading the lungs. The study describes a previously unrecognized GM-CSF-IgM axis and positions IRA B cells as orchestrators of protective IgM immunity. PMID:24821911

  16. Recognition and Prevention of Nosocomial Malnutrition: A Review and A Call to Action!

    PubMed

    Kirkland, Lisa L; Shaughnessy, Erin

    2017-12-01

    Nosocomial malnutrition in hospitalized adults is a morbid, costly, and potentially preventable and treatable problem. Although recognized as contributing to many serious complications of hospitalization, malnutrition is often missed when present on admission and rarely diagnosed if it occurs during hospital stay. Many routine clinical practices such as holding nutrition for testing or failing to address poor intake, when added to acute inflammatory disease states, cause rapid deterioration in nutritional status in up to 70% of inpatients. Malnutrition during hospitalization is associated with increased mortality for years after discharge. In addition, unrecognized (and under-coded) malnutrition is associated with potential lost revenues for hospital systems. Low-cost interventions of recognizing at-risk patients and providing adequate nutrition have the potential to improve patient outcomes and reduce health care costs. Physicians must champion implementation of these interventions, using guidance from national organizations. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Estimation of the Rate of Unrecognized Cross-Contamination with Mycobacterium tuberculosis in London Microbiology Laboratories

    PubMed Central

    Ruddy, M.; McHugh, T. D.; Dale, J. W.; Banerjee, D.; Maguire, H.; Wilson, P.; Drobniewski, F.; Butcher, P.; Gillespie, S. H.

    2002-01-01

    Isolates from patients with confirmed tuberculosis from London were collected over 2.5 years between 1995 and 1997. Restriction fragment length polymorphism (RFLP) analysis was performed by the international standard technique as part of a multicenter epidemiological study. A total of 2,779 samples representing 2,500 individual patients from 56 laboratories were examined. Analysis of these samples revealed a laboratory cross-contamination rate of between 0.54%, when only presumed cases of cross-contamination were considered, and 0.93%, when presumed and possible cases were counted. Previous studies suggest an extremely wide range of laboratory cross-contamination rates of between 0.1 and 65%. These data indicate that laboratory cross-contamination has not been a common problem in routine practice in the London area, but in several incidents patients did receive full courses of therapy that were probably unnecessary. PMID:12409381

  18. Use of dust storm observations on satellite images to identify areas vulnerable to severe wind erosion

    USGS Publications Warehouse

    Breed, C.S.; McCauley, J.F.

    1986-01-01

    Blowing dust is symptomatic of severe wind erosion and deterioration of soils in areas undergoing dessication and/or devegetation. Dust plumes on satellite images can commonly be traced to sources in marginally arable semiarid areas where protective lag gravels or vegetation have been removed and soils are dry, as demonstrated for the Portales Valley, New Mexico. Images from Landsat and manned orbiters such as Skylab and the Space Shuttle are useful for illustrating the regional relations of airborne dust plumes to source areas. Geostationary satellites such as GOES are useful in tracking the time-histories of episodic dust storms. These events sometimes go unrecognized by weather observers and are the precursors of long-term land degradation trends. In areas where soil maps and meteorological data are inadequate, satellite images provide a means for identifying problem areas where measures are needed to control or mitigate wind erosion. ?? 1986 D. Reidel Publishing Company.

  19. In too deep: understanding, detecting and managing DVT.

    PubMed

    Meetoo, Danny

    Venous thromboembolism (VTE), which includes deep vein thrombosis (DVT) and pulmonary embolism (PE), is a serious health and social care problem of the developed world, affecting 1 in 1000 adults every year, and with an annual financial overhead of approximately £640 million. The nature of DVT means that often the condition can go unrecognized until the thrombus becomes an embolus. The pathogenesis of DVT continues to be based on Virchow's triad, which attributes VTE to 'hypercoagulability', 'stasis' and 'intimal injury'. The diagnosis of DVT is often the result of a number of tests performed either sequentially or in combination before mechanical and/or chemical treatment is embarked on. Creating public awareness of DVT and PE is the best way to prevent this condition. Nurses are in an ideal position to discuss the importance of lifestyle changes and other related measures to prevent DVT.

  20. Rapid differentiation of cocci/mixed bacteria from rods in voided urine culture of women with uncomplicated urinary tract infections.

    PubMed

    Yang, Chun-Chun; Yang, Stephen Shei-Dei; Hung, Hui-Ching; Chiang, I-Ni; Peng, Chiung-Hui; Chang, Shang-Jen

    2017-09-01

    To evaluate the ability of laser flow cytometry to predict cocci/mixed growth in the pre-analytical phase of urine specimens. We retrospectively reviewed urine samples from women with uncomplicated urinary tract infections from urologic clinics for study. Urine analyses were performed with laser flow cytometry (UF1000i, Sysmex, Kobe, Japan) and then diagrams were generated (forward scatter vs. fluorescent light scatter). Each specimen (bacteria count >357 BACT/μL) was classified as either cocci bacteria or rods/mixed growth according to the diagrams. Standard urine cultures were performed, and the agreement between cultures and the UF1000i interpretations was analyzed with kappa statistics. Finally, 491 specimens met the criteria for analysis. Among the 376 specimens with single bacteria growth, there were 26 gram-positive cocci (13 Streptococci spp., 7 Staphylococci spp., 6 Enterococci spp.), 1 gram-positive rods (Corynebacterium spp.), and 349 gram-negative rods (273 Escherichia coli, 33 Klebsiella spp., 29 Proteus spp., 6 Citrobacter spp., 4 Enterobacter spp., 3 Pseudomonas spp., and 1 Providencia spp.). There were 115 specimens with two bacteria species or more that were regarded as mixed growth. Agreement of rods or cocci/mixed growth between the laser flow cytometry and urine cultures yielded a kappa value of 0.58. The positive and negative predictive rate of the UF1000i for cocci/mixed growth in voided urine culture was 81.8% and 84.7%, respectively. Through laser flow cytometry, we can predict growth of cocci/mixed growth in the pre-analytical phase of urine culture, thus avoiding unnecessary urine culture and waiting time. © 2016 Wiley Periodicals, Inc.

  1. Impact of Pre-analytic Blood Sample Collection Factors on Metabolomics.

    PubMed

    Townsend, Mary K; Bao, Ying; Poole, Elizabeth M; Bertrand, Kimberly A; Kraft, Peter; Wolpin, Brian M; Clish, Clary B; Tworoger, Shelley S

    2016-05-01

    Many epidemiologic studies are using metabolomics to discover markers of carcinogenesis. However, limited data are available on the influence of pre-analytic blood collection factors on metabolite measurement. We quantified 166 metabolites in archived plasma from 423 Health Professionals Follow-up Study and Nurses' Health Study participants using liquid chromatography-tandem mass spectrometry (LC-MS). We compared multivariable-adjusted geometric mean metabolite LC-MS peak areas across fasting time, season of blood collection, and time of day of blood collection categories. The majority of metabolites (160 of 166 metabolites) had geometric mean peak areas that were within 15% comparing samples donated after fasting 9 to 12 versus ≥13 hours; greater differences were observed in samples donated after fasting ≤4 hours. Metabolite peak areas generally were similar across season of blood collection, although levels of certain metabolites (e.g., bile acids and purines/pyrimidines) tended to be different in the summer versus winter months. After adjusting for fasting status, geometric mean peak areas for bile acids and vitamins, but not other metabolites, differed by time of day of blood collection. Fasting, season of blood collection, and time of day of blood collection were not important sources of variability in measurements of most metabolites in our study. However, considering blood collection variables in the design or analysis of studies may be important for certain specific metabolites, particularly bile acids, purines/pyrimidines, and vitamins. These results may be useful for investigators formulating analysis plans for epidemiologic metabolomics studies, including determining which metabolites to a priori exclude from analyses. Cancer Epidemiol Biomarkers Prev; 25(5); 823-9. ©2016 AACR. ©2016 American Association for Cancer Research.

  2. Setting up a wide panel of patient-derived tumor xenografts of non-small cell lung cancer by improving the preanalytical steps.

    PubMed

    Ilie, Marius; Nunes, Manoel; Blot, Lydia; Hofman, Véronique; Long-Mira, Elodie; Butori, Catherine; Selva, Eric; Merino-Trigo, Ana; Vénissac, Nicolas; Mouroux, Jérôme; Vrignaud, Patricia; Hofman, Paul

    2015-02-01

    With the ongoing need to improve therapy for non-small cell lung cancer (NSCLC) there has been increasing interest in developing reliable preclinical models to test novel therapeutics. Patient-derived tumor xenografts (PDX) are considered to be interesting candidates. However, the establishment of such model systems requires highly specialized research facilities and introduces logistic challenges. We aimed to establish an extensive well-characterized panel of NSCLC xenograft models in the context of a long-distance research network after careful control of the preanalytical steps. One hundred fresh surgically resected NSCLC specimens were shipped in survival medium at room temperature from a hospital-integrated biobank to animal facilities. Within 24 h post-surgery, tumor fragments were subcutaneously xenografted into immunodeficient mice. PDX characterization was performed by histopathological, immunohistochemical, aCGH and next-generation sequencing approaches. For this model system, the tumor take rate was 35%, with higher rates for squamous carcinoma (60%) than for adenocarcinoma (13%). Patients for whom PDX tumors were obtained had a significantly shorter disease-free survival (DFS) compared to patients for whom no PDX tumors (P = 0.039) were obtained. We established a large panel of PDX NSCLC models with a high frequency of mutations (29%) in EGFR, KRAS, NRAS, MEK1, BRAF, PTEN, and PI3KCA genes and with gene amplification (20%) of c-MET and FGFR1. This new patient-derived NSCLC xenograft collection, established regardless of the considerable time required and the distance between the clinic and the animal facilities, recapitulated the histopathology and molecular diversity of NSCLC and provides stable and reliable preclinical models for human lung cancer research. © 2014 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  3. Precise turnaround time measurement of laboratory processes using radiofrequency identification technology.

    PubMed

    Mayer, Horst; Brümmer, Jens; Brinkmann, Thomas

    2011-01-01

    To implement Lean Six Sigma in our central laboratory we conducted a project to measure single pre-analytical steps influencing turnaround time (TAT) of emergency department (ED) serum samples. The traditional approach of extracting data from the Laboratory Information System (LIS) for a retrospective calculation of a mean TAT is not suitable. Therefore, we used radiofrequency identification (RFID) chips for real time tracking of individual samples at any pre-analytical step. 1,200 serum tubes were labelled with RFID chips and were provided to the emergency department. 3 RFID receivers were installed in the laboratory: at the outlet of the pneumatic tube system, at the centrifuge, and in the analyser area. In addition, time stamps of sample entry at the automated sample distributor and communication of results from the analyser were collected from LIS. 1,023 labelled serum tubes arrived at our laboratory. 899 RFID tags were used for TAT calculation. The following transfer times were determined (median 95th percentile in min:sec): pneumatic tube system --> centrifuge (01:25/04:48), centrifuge --> sample distributor (14:06/5:33), sample distributor --> analysis system zone (02:39/15:07), analysis system zone --> result communication (12:42/22:21). Total TAT was calculated at 33:19/57:40 min:sec. Manual processes around centrifugation were identified as a major part of TAT with 44%/60% (median/95th percentile). RFID is a robust, easy to use, and error-free technology and not susceptible to interferences in the laboratory environment. With this study design we were able to measure significant variations in a single manual sample transfer process. We showed that TAT is mainly influenced by manual steps around the centrifugation process and we concluded that centrifugation should be integrated in solutions for total laboratory automation.

  4. Implementation of a new 'community' laboratory CD4 service in a rural health district in South Africa extends laboratory services and substantially improves local reporting turnaround time.

    PubMed

    Coetzee, L M; Cassim, N; Glencross, D K

    2015-12-16

    The CD4 integrated service delivery model (ITSDM) provides for reasonable access to pathology services across South Africa (SA) by offering three new service tiers that extend services into remote, under-serviced areas. ITSDM identified Pixley ka Seme as such an under-serviced district. To address the poor service delivery in this area, a new ITSDM community (tier 3) laboratory was established in De Aar, SA. Laboratory performance and turnaround time (TAT) were monitored post implementation to assess the impact on local service delivery. Using the National Health Laboratory Service Corporate Data Warehouse, CD4 data were extracted for the period April 2012-July 2013 (n=11,964). Total mean TAT (in hours) was calculated and pre-analytical and analytical components assessed. Ongoing testing volumes, as well as external quality assessment performance across ten trials, were used to indicate post-implementation success. Data were analysed using Stata 12. Prior to the implementation of CD4 testing at De Aar, the total mean TAT was 20.5 hours. This fell to 8.2 hours post implementation, predominantly as a result of a lower pre-analytical mean TAT reducing from a mean of 18.9 to 1.8 hours. The analytical testing TAT remained unchanged after implementation and monthly test volumes increased by up to 20%. External quality assessment indicated adequate performance. Although subjective, questionnaires sent to facilities reported improved service delivery. Establishing CD4 testing in a remote community laboratory substantially reduces overall TAT. Additional community CD4 laboratories should be established in under-serviced areas, especially where laboratory infrastructure is already in place.

  5. Laboratory diagnosis of gestational diabetes: An in silico investigation into the effects of pre-analytical processing on the diagnostic sensitivity and specificity of the oral glucose tolerance test.

    PubMed

    Mansell, Erin; Lunt, Helen; Docherty, Paul

    2017-06-01

    Delayed separation of red cells from plasma causes pre analytical glucose loss, which in turn results in an under-diagnosis of GDM (gestational diabetes) based on the OGTT (oral glucose tolerance test). In silico investigations may help laboratory decision making, when exploring pragmatic improvements to sample processing. Late pregnancy 0, 1 and 2h 75g OGTT values were obtained from two distinct populations of pregnant women: 1. Values derived from the HAPO (Hyperglycemia and Adverse Pregnancy Outcome) Study and 2. New Zealand women identified as at higher risk of GDM by their caregivers, undergoing OGTT during routine antenatal care. In both populations studied, in silico modelling focussed on the effects of pre-analytical delays in plasma separation, when using fluoride collection tubes. Using a model that 'batched' samples from the three OGTT collection times, diagnostic sensitivity was estimated as follows: 66.1% for HAPO research population and 48.4% for the 1305 women receiving routine antenatal care. If samples were not batched, but processed shortly after each blood sample was collected, then sensitivity increased to 81%. Exploration of a range of clinical and laboratory scenarios using in silico modelling, showed that delaying the processing of pregnancy OGTT samples, using batched sample collection into fluoride tubes, causes unacceptable loss of GDM diagnostic sensitivity across two distinct population groups. This modelling approach will hopefully provide information that helps with final decision making around improved laboratory processing techniques. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  6. Identification of unrecognized tundra fire events on the north slope of Alaska

    USGS Publications Warehouse

    Jones, Benjamin M.; Breen, Amy L.; Gaglioti, Benjamin V.; Mann, Daniel H.; Rocha, Adrian V.; Grosse, Guido; Arp, Christopher D.; Kunz, Michael L.; Walker, Donald A.

    2013-01-01

    Characteristics of the natural fire regime are poorly resolved in the Arctic, even though fire may play an important role cycling carbon stored in tundra vegetation and soils to the atmosphere. In the course of studying vegetation and permafrost-terrain characteristics along a chronosequence of tundra burn sites from AD 1977, 1993, and 2007 on the North Slope of Alaska, we discovered two large, previously unrecognized tundra fires. The Meade River fire burned an estimated 500 km2 and the Ketik River fire burned an estimated 1200 km2. Based on radiocarbon dating of charred twigs, analysis of historic aerial photography, and regional climate proxy data, these fires likely occurred between AD 1880 and 1920. Together, these events double the estimated burn area on the North Slope of Alaska over the last ~100 to 130 years. Assessment of vegetation succession along the century-scale chronosequence of tundra fire disturbances demonstrates for the first time on the North Slope of Alaska that tundra fires can facilitate the invasion of tundra by shrubs. Degradation of ice-rich permafrost was also evident at the fire sites and likely aided in the presumed changes of the tundra vegetation postfire. Other previously unrecognized tundra fire events likely exist in Alaska and other Arctic regions and identification of these sites is important for better understanding disturbance regimes and carbon cycling in Arctic tundra.

  7. Metabolomic analysis-Addressing NMR and LC-MS related problems in human feces sample preparation.

    PubMed

    Moosmang, Simon; Pitscheider, Maria; Sturm, Sonja; Seger, Christoph; Tilg, Herbert; Halabalaki, Maria; Stuppner, Hermann

    2017-10-31

    Metabolomics is a well-established field in fundamental clinical research with applications in different human body fluids. However, metabolomic investigations in feces are currently an emerging field. Fecal sample preparation is a demanding task due to high complexity and heterogeneity of the matrix. To gain access to the information enclosed in human feces it is necessary to extract the metabolites and make them accessible to analytical platforms like NMR or LC-MS. In this study different pre-analytical parameters and factors were investigated i.e. water content, different extraction solvents, influence of freeze-drying and homogenization, ratios of sample weight to extraction solvent, and their respective impact on metabolite profiles acquired by NMR and LC-MS. The results indicate that profiles are strongly biased by selection of extraction solvent or drying of samples, which causes different metabolites to be lost, under- or overstated. Additionally signal intensity and reproducibility of the measurement were found to be strongly dependent on sample pre-treatment steps: freeze-drying and homogenization lead to improved release of metabolites and thus increased signals, but at the same time induced variations and thus deteriorated reproducibility. We established the first protocol for extraction of human fecal samples and subsequent measurement with both complementary techniques NMR and LC-MS. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. The Dilemma of Mountain Roads

    EPA Science Inventory

    Mountain roads and trails are proliferating throughout developing Southeast Asia with severe but largely unrecognized long-term consequences related to effects of landslides and surface erosion on communities and downstream resources.

  9. Male songbirds provide indirect parental care by guarding females during incubation

    USGS Publications Warehouse

    Fedy, B.C.; Martin, T.E.

    2009-01-01

    Across many taxa, guarding of fertile mates is a widespread tactic that enhances paternity assurance. However, guarding of mates can also occur during the nonfertile period, and the fitness benefits of this behavior are unclear. Male songbirds, for example, sometimes guard nonfertile females during foraging recesses from incubation. We hypothesized that guarding postreproductive mates may have important, but unrecognized, benefits by enhancing female foraging efficiency, thereby increasing time spent incubating eggs. We tested the hypothesis in 2 songbird species by examining female behavior during natural and experimentally induced absences of males. Male absence caused increased vigilance in foraging females that decreased their efficiency and resulted in less time spent incubating eggs. Male guarding of nonfertile females can thus provide a previously unrecognized form of indirect parental care.

  10. Feasibility and quality development of biomaterials in the pretest studies of the German National Cohort.

    PubMed

    Kühn, A; Nieters, A; Köttgen, A; Goek, O N; Michels, K; Nöthlings, U; Jacobs, G; Meisinger, C; Pessler, F; Akmatov, M F; Kühnisch, J; Moebus, S; Glocker, E; Naus, S; Keimling, M; Leitzmann, M; Linseisen, J; Sarioglu, H; von Toerne, C; Hauck, S M; Wallaschofski, H; Wichmann, H E; Illig, Thomas

    2014-11-01

    The German National Cohort (GNC) is designed to address research questions concerning a wide range of possible causes of major chronic diseases (e.g. cancer, diabetes, infectious, allergic, neurologic and cardiovascular diseases) as well as to identify risk factors and prognostic biomarkers for early diagnosis and prevention of these diseases. The collection of biomaterials in combination with extensive information from questionnaires and medical examinations represents one of the central study components. In two pretest studies of the German National Cohort conducted between 2011 and 2013, a range of biomaterials from a defined number of participants was collected. Ten study centres were involved in pretest 1 and 18 study centres were involved in pretest 2. Standard operation procedures (SOP) were developed and evaluated to minimize pre-analytical artefacts during biosample collection. Within the pretest studies different aspects concerning feasibility of sample collection/preparation [pretest 1 (a)] and quality control of biomarkers and proteome analyses were investigated [pretest 1 (b), (c)]. Additionally, recruitment of study participants for specific projects and examination procedures of all study centres in a defined time period according to common standards as well as transportation and decentralized storage of biological samples were tested (pretest 2). These analyses will serve as the basis for the biomaterial collection in the main study of the GNC starting in 2014. Participants, randomly chosen from the population (n = 1000 subjects recruited at ten study sites in pretest 1) were asked to donate blood, urine, saliva and stool samples. Additionally, nasal and oropharyngeal swabs were collected at the study sites and nasal swabs were collected by the participants at home. SOPs for sample collection, preparation, storage and transportation were developed and adopted for pretest 2. In pretest 2, 18 study sites (n = 599 subjects) collected biomaterials mostly identical to pretest 1. Biomarker analyses to test the quality of the biomaterials were performed. In pretest 1 and 2, it was feasible to collect all biomaterials from nearly all invited participants without major problems. The mean response rate of the subjects was 95 %. As one important result we found for example that after blood draw the cellular fraction should be separated from the plasma and serum fractions during the first hour with no significant variation for up to 6 h at 4 ℃ for all analysed biomarkers. Moreover, quality control of samples using a proteomics approach showed no significant clustering of proteins according to different storage conditions. All developed SOPs were validated for use in the main study after some adaptation and modification. Additionally, electronic and paper documentation sheets were developed and tested to record time stamps, volumes, freezing times, and aliquot numbers of the collected biomaterials. The collection of the biomaterials was feasible without major problems at all participating study sites. However, the processing times were in some cases too long. To avoid pre-analytical artefacts in sample collection, appropriate standardisation among the study sites is necessary. To achieve this, blood and urine collection will have to be adapted to specific conditions of usage of liquid handling robots, which will be available at all participating study centres in the main study of the GNC. Strict compliance with the SOPs, thorough training of the staff and accurate documentation are mandatory to obtain high sample quality for later analyses. The so obtained biomaterials represent a valuable resource for research on infectious and other common complex diseases in the GNC.

  11. Identification of Analytical Factors Affecting Complex Proteomics Profiles Acquired in a Factorial Design Study with Analysis of Variance: Simultaneous Component Analysis.

    PubMed

    Mitra, Vikram; Govorukhina, Natalia; Zwanenburg, Gooitzen; Hoefsloot, Huub; Westra, Inge; Smilde, Age; Reijmers, Theo; van der Zee, Ate G J; Suits, Frank; Bischoff, Rainer; Horvatovich, Péter

    2016-04-19

    Complex shotgun proteomics peptide profiles obtained in quantitative differential protein expression studies, such as in biomarker discovery, may be affected by multiple experimental factors. These preanalytical factors may affect the measured protein abundances which in turn influence the outcome of the associated statistical analysis and validation. It is therefore important to determine which factors influence the abundance of peptides in a complex proteomics experiment and to identify those peptides that are most influenced by these factors. In the current study we analyzed depleted human serum samples to evaluate experimental factors that may influence the resulting peptide profile such as the residence time in the autosampler at 4 °C, stopping or not stopping the trypsin digestion with acid, the type of blood collection tube, different hemolysis levels, differences in clotting times, the number of freeze-thaw cycles, and different trypsin/protein ratios. To this end we used a two-level fractional factorial design of resolution IV (2(IV)(7-3)). The design required analysis of 16 samples in which the main effects were not confounded by two-factor interactions. Data preprocessing using the Threshold Avoiding Proteomics Pipeline (Suits, F.; Hoekman, B.; Rosenling, T.; Bischoff, R.; Horvatovich, P. Anal. Chem. 2011, 83, 7786-7794, ref 1) produced a data-matrix containing quantitative information on 2,559 peaks. The intensity of the peaks was log-transformed, and peaks having intensities of a low t-test significance (p-value > 0.05) and a low absolute fold ratio (<2) between the two levels of each factor were removed. The remaining peaks were subjected to analysis of variance (ANOVA)-simultaneous component analysis (ASCA). Permutation tests were used to identify which of the preanalytical factors influenced the abundance of the measured peptides most significantly. The most important preanalytical factors affecting peptide intensity were (1) the hemolysis level, (2) stopping trypsin digestion with acid, and (3) the trypsin/protein ratio. This provides guidelines for the experimentalist to keep the ratio of trypsin/protein constant and to control the trypsin reaction by stopping it with acid at an accurately set pH. The hemolysis level cannot be controlled tightly as it depends on the status of a patient's blood (e.g., red blood cells are more fragile in patients undergoing chemotherapy) and the care with which blood was sampled (e.g., by avoiding shear stress). However, its level can be determined with a simple UV spectrophotometric measurement and samples with extreme levels or the peaks affected by hemolysis can be discarded from further analysis. The loadings of the ASCA model led to peptide peaks that were most affected by a given factor, for example, to hemoglobin-derived peptides in the case of the hemolysis level. Peak intensity differences for these peptides were assessed by means of extracted ion chromatograms confirming the results of the ASCA model.

  12. 36 CFR 60.14 - Changes and revisions to properties listed in the National Register.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... exist for altering a boundary: Professional error in the initial nomination, loss of historic integrity... previously unrecognized significance in American history, architecture, archeology, engineering or culture...

  13. Hidden weapons of microbial destruction in plant genomes

    PubMed Central

    Manners, John M

    2007-01-01

    Recent bioinformatic analyses of sequenced plant genomes reveal a previously unrecognized abundance of genes encoding antimicrobial cysteine-rich peptides, representing a formidable and dynamic defense arsenal against plant pests and pathogens. PMID:17903311

  14. Comorbid fibromyalgia: A qualitative review of prevalence and importance.

    PubMed

    Fitzcharles, M-A; Perrot, S; Häuser, W

    2018-05-26

    Fibromyalgia (FM) may be an unrecognized cause of suffering for persons with an array of medical conditions. This is especially true for illness that is characterized by pain of any nature. Once believed to be a unique diagnosis, FM is recently reported to occur concomitantly with various rheumatic diseases, and importantly adversely impacts global health status. However, there is increasing report of FM associated with other diseases that are not defined by chronic pain. This qualitative review examines the evidence for comorbid FM in illness, and where available the effect of FM on the primary disease. Other than for musculoskeletal disorders, the published literature reporting an association of FM with illness is limited with scanty reports for some neurological, gastrointestinal, mental health and other overlapping pain conditions. Comorbid FM adversely affects both health status and outcome for rheumatic diseases, but with limited study in other diseases. When unrecognized, comorbid FM may be mistaken as poor control of the primary disease, leading to incorrect treatment decisions. FM may be a neglected condition that pervades many conditions and may contribute to the burden of illness. Physicians should be alert to the possibility of comorbid FM, and symptoms of FM should be specifically addressed. Comorbid fibromyalgia (FM) in other medical conditions is largely unrecognized. When reported as accompanying rheumatic diseases, FM adversely affects global health status. With limited reports of comorbid FM with other conditions, neglect to diagnose comorbid FM may misdirect treatments. © 2018 European Pain Federation - EFIC®.

  15. Some Neglected Economic Factors behind Recent Tax and Spending Limitation Movements.

    ERIC Educational Resources Information Center

    Boskin, Michael J.

    1979-01-01

    The demand for tax and spending limitations is caused primarily by the generally unrecognized complete lack of growth in real private income since 1973. Journal availability: see EA 511 898. (Author/IRT)

  16. Hope: A Panacea Unrecognized

    PubMed Central

    Obayuwana, Alphonsus O.

    1980-01-01

    This paper identifies stress as a common and constant irritation to human homeostasis, evaluates the role of hope in the maintenance of health, and recommends a method of anticipatory care for securing optimum health for mankind. PMID:7373668

  17. Satisfying regulatory and accreditation requirements for quality control.

    PubMed

    Ehrmeyer, Sharon S

    2013-03-01

    The Clinical Laboratory Improvement Amendments of 1988 (CLIA) requires all US clinical laboratories that test "materials derived from the human body for the purpose of providing information for the diagnosis, prevention, or treatment of any disease..." to be regulated. The CLIA mandates are site neutral; based on test complexity; and focus on the three phases of the testing process (preanalytical, analytical, and postanalytical). Many testing sites choose to meet the CLIA requirements by following the testing standards of a professional accreditation organization deemed by the Centers for Medicare and Medicaid Services. The three principal organizations are The Joint Commission, the College of American Pathologists, and COLA. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. "Bed Side" Human Milk Analysis in the Neonatal Intensive Care Unit: A Systematic Review.

    PubMed

    Fusch, Gerhard; Kwan, Celia; Kotrri, Gynter; Fusch, Christoph

    2017-03-01

    Human milk analyzers can measure macronutrient content in native breast milk to tailor adequate supplementation with fortifiers. This article reviews all studies using milk analyzers, including (i) evaluation of devices, (ii) the impact of different conditions on the macronutrient analysis of human milk, and (iii) clinical trials to improve growth. Results lack consistency, potentially due to systematic errors in the validation of the device, or pre-analytical sample preparation errors like homogenization. It is crucial to introduce good laboratory and clinical practice when using these devices; otherwise a non-validated clinical usage can severely affect growth outcomes of infants. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. The Da Vinci European BioBank: A Metabolomics-Driven Infrastructure

    PubMed Central

    Carotenuto, Dario; Luchinat, Claudio; Marcon, Giordana; Rosato, Antonio; Turano, Paola

    2015-01-01

    We present here the organization of the recently-constituted da Vinci European BioBank (daVEB, https://www.davincieuropeanbiobank.org/it). The biobank was created as an infrastructure to support the activities of the Fiorgen Foundation (http://www.fiorgen.net/), a nonprofit organization that promotes research in the field of pharmacogenomics and personalized medicine. The way operating procedures concerning samples and data have been developed at daVEB largely stems from the strong metabolomics connotation of Fiorgen and from the involvement of the scientific collaborators of the foundation in international/European projects aimed to tackle the standardization of pre-analytical procedures and the promotion of data standards in metabolomics. PMID:25913579

  20. Recommendations for accreditation of laboratories in molecular biology of hematologic malignancies.

    PubMed

    Flandrin-Gresta, Pascale; Cornillet, Pascale; Hayette, Sandrine; Gachard, Nathalie; Tondeur, Sylvie; Mauté, Carole; Cayuela, Jean-Michel

    2015-01-01

    Over recent years, the development of molecular biology techniques has improved the hematological diseases diagnostic and follow-up. Consequently, these techniques are largely used in the biological screening of these diseases; therefore the Hemato-oncology molecular diagnostics laboratories must be actively involved in the accreditation process according the ISO 15189 standard. The French group of molecular biologists (GBMHM) provides requirements for the implementation of quality assurance for the medical molecular laboratories. This guideline states the recommendations for the pre-analytical, analytical (methods validation procedures, quality controls, reagents), and post-analytical conditions. In addition, herein we state a strategy for the internal quality control management. These recommendations will be regularly updated.

  1. Lessons from a Successful Implementation of a Computerized Provider Order Entry System

    PubMed Central

    Jacobs, Brian R.; Hallstrom, Craig K.; Hart, Kim Ward; Mahoney, Daniela; Lykowski, Gayle

    2007-01-01

    OBJECTIVES The electronic health record (EHR) can improve patient safety, care efficiency, cost effectiveness and regulatory compliance. Cincinnati Children's Hospital Medical Center (CCHMC) has successfully implemented an Integrating Clinical Information System (ICIS) that includes Computerized Provider Order Entry (CPOE). This review describes some of the unanticipated challenges and solutions identified during the implementation of ICIS. METHODS Data for this paper was derived from user-generated feedback within the ICIS. Feedback reports were reviewed and placed into categories based on root cause of the issue. Recurring issues or problems which led to potential or actual patient injury are included. RESULTS Nine distinct challenges were identified: 1) Deterioration in communication; 2) Excessive system alerts to users; 3) Unrecognized discontinuation of medications; 4) Unintended loss of orders; 5) Loss of orders during implementation; 6) Amplification of errors; 7) Unintentional generation of patient care orders by system analysts; 8) Persistence of specific patient care order instructions; 9) Verbal orders entered under the incorrect clinician. CONCLUSIONS Unanticipated challenges are expected when implementing EHRs. The implementation plan for any EHR should include methods to identify, evaluate and repair problems quickly. While continued challenges with this complex system are expected, we believe that the EHR will continue to facilitate improved patient care and safety. The lessons learned at CCHMC will permit other institutions to avoid some of these challenges and design robust processes to detect and respond to problems in a timely fashion to ensure implementation success. PMID:23055847

  2. Associations between bride price stress and intimate partner violence amongst pregnant women in Timor-Leste.

    PubMed

    Rees, Susan; Mohsin, Mohammed; Tay, Alvin Kuowei; Soares, Elisa; Tam, Natalino; da Costa, Zelia; Tol, Wietse; Silove, Derrick

    2017-08-28

    Reducing violence against women is a global public health priority, particularly in low-income and conflict-affected societies. However, more needs to be known about the causes of intimate partner violence (IPV) in these settings, including the stress of bride price obligations. The representative study of women attending ante-natal clinics in Dili, Timor-Leste was conducted between June, 2013 and September, 2014 with 1672 pregnant women, a response rate of 96%. We applied contextually developed measures for the stress of bride price and poverty, and the World Health Organisation measure for intimate partner violence. Compared to those with no problems with bride price, women with moderate or serious problems with that custom reported higher rates of IPV (18.0% vs. 43.6%). Adjusting for socio-demographic factors, multivariate analysis revealed that ongoing poverty (OR = 1.75, 95% CI: 1.20-2.56) was significantly associated with IPV. Importantly, the strongest association with IPV was problems with bride price (OR = 2.73, 95% CI: 1.86-4.01). This is the first large consecutively sampled study to demonstrate a strong association between the stressors of bride price and poverty with IPV. Notably, bride price stress had the strongest association with IPV. Revealing this hitherto unrecognized factor of bride price stress may prove pivotal in guiding policy and interventions aimed at reducing IPV, and thereby improve the health and psychosocial status of women in low income and conflict-affected settings.

  3. Insufficient sleep syndrome: An unrecognized but important clinical entity.

    PubMed

    Kohyama, Jun; Anzai, Yuki; Ono, Makoto; Kishino, Ai; Tamanuki, Keita; Takada, Kazuma; Inoue, Kento; Horiuchi, Maho; Hatai, Yoshiho

    2018-04-01

    A sleep clinic for adults and children was established in the Tokyo Bay Urayasu Ichikawa Medical Centre, in August 2012. Given that few sleep clinics are available in Japan specifically for children, this clinic provides the opportunity to provide data on child patients with sleep problems. Records of patients who visited the sleep clinic at the Tokyo Bay Urayasu Ichikawa Medical Centre aged ≤20 years at the first visit were retrospectively examined, along with the initial and final diagnoses. Of 2,157 patients who visited the sleep clinic at Tokyo Bay Urayasu Ichikawa Medical Centre between August 2012 and March 2017, 181 were ≤20 years old. In these 181 patients, the most frequent final diagnosis was insufficient sleep syndrome (ISS), n = 56, followed by circadian rhythm sleep-wake disorder, n = 28; insomnia, n = 28; and sleep-related movement disorder, n = 15. Insufficient sleep produces various brain dysfunctions in both adults and children, and is associated with behavioral, cognitive and physical problems, as well as with atypical early development. Insufficient sleep has also been reported to cause obesity. Insufficient sleep-induced obesity is often associated with the occurrence of metabolic syndrome. More effort is needed to ensure that children are receiving sufficient sleep. © 2018 Japan Pediatric Society.

  4. Evolution of global contribution in multi-level threshold public goods games with insurance compensation

    NASA Astrophysics Data System (ADS)

    Du, Jinming; Tang, Lixin

    2018-01-01

    Understanding voluntary contribution in threshold public goods games has important practical implications. To improve contributions and provision frequency, free-rider problem and assurance problem should be solved. Insurance could play a significant, but largely unrecognized, role in facilitating a contribution to provision of public goods through providing insurance compensation against the losses. In this paper, we study how insurance compensation mechanism affects individuals’ decision-making under risk environments. We propose a multi-level threshold public goods game model where two kinds of public goods games (local and global) are considered. Particularly, the global public goods game involves a threshold, which is related to the safety of all the players. We theoretically probe the evolution of contributions of different levels and free-riders, and focus on the influence of the insurance on the global contribution. We explore, in both the cases, the scenarios that only global contributors could buy insurance and all the players could. It is found that with greater insurance compensation, especially under high collective risks, players are more likely to contribute globally when only global contributors are insured. On the other hand, global contribution could be promoted if a premium discount is given to global contributors when everyone buys insurance.

  5. The vector homology problem in diagnostic nucleic acid hybridization of clinical specimens.

    PubMed Central

    Ambinder, R F; Charache, P; Staal, S; Wright, P; Forman, M; Hayward, S D; Hayward, G S

    1986-01-01

    Nucleic acid hybridization techniques using cloned probes are finding application in assays of clinical specimens in research and diagnostic laboratories. The probes that we and others have used are recombinant plasmids composed of viral inserts and bacterial plasmid vectors such as pBR322. We suspected that there was material homologous to pBR322 present in many clinical samples. because hybridization occurred in samples which lacked evidence of virus by other techniques. If the presence of this vector-homologous material was unrecognized, hybridization in the test sample might erroneously be interpreted as indicating the presence of viral sequences. In this paper we demonstrate specific hybridization of labeled pBR322 DNA with DNA from various clinical samples. Evidence is presented that nonspecific probe trapping could not account for this phenomenon. In mixing experiments, it is shown that contamination of clinical samples with bacteria would explain such a result. Approaches tested to circumvent this problem included the use of isolated insert probes, alternate cloning vectors, and cold competitor pBR322 DNA in prehybridization and hybridization mixes. None proved entirely satisfactory. We therefore emphasize that it is essential that all hybridization detection systems use a control probe of the vector alone in order to demonstrate the absence of material with vector homology in the specimen tested. Images PMID:3013928

  6. Sex trafficking of adolescents and young adults in the United States: healthcare provider's role.

    PubMed

    Chaffee, Tonya; English, Abigail

    2015-10-01

    Sex trafficking of adolescents and young adults is both a human rights violation and a public health problem, globally and in the United States. Healthcare providers, including obstetricians and gynecologists, interact with victims, often while they remain under their traffickers' control, but because of providers' lack of training in identification and response many victims go unrecognized and unaided. This review provides an overview of the definitions of sex trafficking and commercial sexual exploitation, contributing factors, health consequences, recruitment of victims, and identification and response by healthcare providers. The literature on definitions and risk factors associated with sex trafficking is growing; however, literature on healthcare providers' role in addressing sex trafficking remains more limited. It is increasingly recognized that healthcare providers have an important role in victim identification and response and as advocates, collaborating with national, regional, and local agencies to increase awareness of sex trafficking as a public health problem and to address the needs of adolescent and young adult victims and survivors globally and in the United States. As professionals who interact with adolescent and young adult victims of sex trafficking, healthcare providers have an important role: in collaboration with other professionals and agencies they can help to identify, respond to, extricate, protect, and advocate for victims and survivors.

  7. Prevention and early recognition: the role of family pediatrician.

    PubMed

    Moretti, Carlo; Foltran, Francesca

    2012-05-14

    Even if it is empirically evident that pediatricians play a key role in diagnosis, treatment and prevention of FB injuries, almost all studies have focused on the subset of injured children who receive medical care in the hospital or in the Emergency Department; moreover, a lack of scientific interest to improve information about pediatric injuries in primary care seems to exist. Primary care physicians can play an important role if they promptly identify suspect unrecognized FB aspiration in children. Moreover, prevention is a cornerstone of pediatric practice, and pediatricians, as reliable sources of information, may be efficacious in promoting injury prevention message. Given the paucity of works finalized to evaluate the role of injury preventive strategies in primary care it is arduous to identify an ideal approach to implement counseling strategies. However, evidences obtained elsewhere have suggested that effective preventive strategy origins from an effective communication technique, moreover, the probability of success is greater when the attention toward the problem is greater; particularly, the postpartum period is a time of tremendous change, increased health problems, and emotional upheaval for new parents. General practitioners are in an ideal position to assist families during this period and may consider a sooner rather than later, approach to injury prevention education. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  8. RNA design rules from a massive open laboratory

    PubMed Central

    Lee, Jeehyung; Kladwang, Wipapat; Lee, Minjae; Cantu, Daniel; Azizyan, Martin; Kim, Hanjoo; Limpaecher, Alex; Gaikwad, Snehal; Yoon, Sungroh; Treuille, Adrien; Das, Rhiju

    2014-01-01

    Self-assembling RNA molecules present compelling substrates for the rational interrogation and control of living systems. However, imperfect in silico models—even at the secondary structure level—hinder the design of new RNAs that function properly when synthesized. Here, we present a unique and potentially general approach to such empirical problems: the Massive Open Laboratory. The EteRNA project connects 37,000 enthusiasts to RNA design puzzles through an online interface. Uniquely, EteRNA participants not only manipulate simulated molecules but also control a remote experimental pipeline for high-throughput RNA synthesis and structure mapping. We show herein that the EteRNA community leveraged dozens of cycles of continuous wet laboratory feedback to learn strategies for solving in vitro RNA design problems on which automated methods fail. The top strategies—including several previously unrecognized negative design rules—were distilled by machine learning into an algorithm, EteRNABot. Over a rigorous 1-y testing phase, both the EteRNA community and EteRNABot significantly outperformed prior algorithms in a dozen RNA secondary structure design tests, including the creation of dendrimer-like structures and scaffolds for small molecule sensors. These results show that an online community can carry out large-scale experiments, hypothesis generation, and algorithm design to create practical advances in empirical science. PMID:24469816

  9. Depression and Heart Diseases: Leading Health Problems.

    PubMed

    Raič, Matea

    2017-12-01

    Depression is the most common psychiatric disorder in the world population and the most frequent mental disorder in a primary health care. Unrecognized and untreated depression is associated with a poor outcome of treated chronic diseases which co-exist with depression. Depression and cardiovascular diseases are bidirectional related conditions, risks are for each other, and they often co-exist. Depression is a common disorder in cardiovascular patients with a prevalence of 20% to 45%, which is much more frequent than in the general population. In cardiac patients with acute myocardial infarction, depression occurs three times more often than in the general population. Depression has a direct effect on the pathophysiological changes of various organ systems, changing the values of blood pressure, heart rate, vasomotor tone, vascular resistance, blood viscosity and plasma volume. The potential mechanism for developing heart disease in depressed patients includes hypothalamic-pituitary-adrenal gland dysfunction, increased proinflammatory and prothrombotic factor activity, reduced omega-3 fatty acids, reduced heart rate variability, smoking, physical inactivity, reduced mood, self-esteem and self-efficacy.

  10. Contact dermatitis is an unrecognized problem in the construction industry: Comparison of four different assessment methods.

    PubMed

    Timmerman, Johan G; Heederik, Dick; Spee, Ton; van Rooy, Frits G; Krop, Esmeralda J M; Rustemeyer, Thomas; Smit, Lidwien A M

    2017-10-01

    A high contact dermatitis symptoms prevalence has been observed in Dutch construction workers. Contact dermatitis was diagnosed by an expert panel using questionnaire data and photographs of 751 subjects' hands. A subset was evaluated by two occupational physicians. Their diagnoses were compared to those of the expert panel. In addition, two self-reported questionnaire-based assessment methods were compared to the expert panel evaluation. Associations between contact dermatitis and determinants were assessed using log-binomial regression analysis. Contact dermatitis prevalence was high: 61.4% (expert panel's diagnosis) and 32.9% (self-reported). Agreement between occupational physicians and the expert panel was low but increased after training. Washing hands with solvents and performing job-related tasks at home were related to contact dermatitis. Contact dermatitis prevalence among construction workers is high. Recognition of contact dermatitis by occupational physicians is poor but can be improved by training. Awareness of skin disorders should be raised. © 2017 Wiley Periodicals, Inc.

  11. An overview of treatments for obesity in a population with mental illness.

    PubMed

    Taylor, Valerie H; Stonehocker, Brian; Steele, Margot; Sharma, Arya M

    2012-01-01

    Obesity is associated with early mortality and has overtaken smoking as the health problem with the greatest impact on quality of life, mortality, and morbidity. Despite public health initiatives and numerous commercial enterprises focusing on weight loss, obesity rates continue to rise. In part, this is because obesity is a multifaceted, complex illness, impacted by numerous social, psychological, and behavioural factors that are unrecognized in most current initiatives. One significant factor associated with obesity is mental illness. While having a psychiatric illness does not make weight gain inevitable, it does often require that additional tools be added to lifestyle recommendations around diet and exercise. The following article reviews the common approaches to obesity management and addresses how these strategies can be implemented in psychiatric care. It is important that health professionals involved in the care of people with a mental illness become familiar with the interventions available to control and treat the obesity epidemic, as this will improve treatment compliance and ultimately lead to improved physical and psychological outcomes.

  12. Development of a plastic surgical teaching service in a women's correctional institution.

    PubMed

    Fisher, J C; Powers, W E; Tuerk, D B; Edgerton, M T

    1975-03-01

    A plastic surgical teaching service has been organized at a women's correctional institution to provide a previously unrecognized medical need and to serve a valuable educational function for our residents in training. A total of 177 surgical candidates demonstrating a wide range of reconstructive problems including tattoos, scars, keloids, neoplasms of the skin and hands, deformities of the face and breasts, and numerous disabilities of the hands were identified among 241 inmates requesting examination. Thus far, 116 operative procedures have been performed on 101 patients. Patient acceptance has been high, and the support of prison authorities has been enthusiastic. Persistent efforts to convince legislators of the wisdom of supporting this program financially have only been partially successful and will require further accumulation of sociologic data bearing on the rehabilitative potential of the detained patient with a correctable deformity. Meanwhile, residents in training gain maturity as they provide a very "private" type of service for what has traditionally been considered a very "public" population of patients.

  13. Sources of lead exposure in Mexico City.

    PubMed Central

    Romieu, I; Palazuelos, E; Hernandez Avila, M; Rios, C; Muñoz, I; Jimenez, C; Cahero, G

    1994-01-01

    Many countries, including Mexico, are facing a largely unrecognized epidemic of low-level lead poisoning. Mexico is the sixth largest lead-producing country in the world, and 40% of its production is used locally in different industrial processes that cause lead contamination of the environment. The major sources and pathways of lead exposure among the Mexican population are gasoline emissions, lead-glazed ceramics, leaded paint, and lead in canned foods and beverages. In this paper we present evidence for the presence of lead in different environmental media and its impact on blood lead levels of the Mexican population. Although during the last few years important measures have been implemented to decrease lead exposure, our findings suggest that lead poisoning is still an important problem in Mexico. There is an urgent need for regulatory policies that implement stricter control to protect the Mexican population. There is also a need to develop adequate programs to reduce the lead burden and the associated health effects in the population that has been chronically exposed. Images Figure 1. PMID:7523102

  14. [Amputation and equipment of the lower limb during the Revolution and the Empire].

    PubMed

    Vesselle, Benoît

    2014-01-01

    During the French Revolution and Napoleon's campaigns, above-knee or below-knee amputations were performed either immediately or with a delay, which favoured septic problems. A rapidly operated amputation by a well-trained surgeon was the best way to save the life of a soldier who suffered from an open comminuted fracture of a limb. The conditions on military campaigns were indeed hard ones: doctors and surgeons had practically no resources and the transportation of severely injured persons was difficult. Such conditions favoured the pain and the danger caused by an injury, and it was rather impossible for the medical corps to lavish repeated treatments on the wounds. The amputated soldiers were then given prostheses: either a traditional peg-leg, with a flexed knee joint for trans-tibial amputations, or an "imitative" prosthesis, which tended to look like a real leg with eventually an articulated knee or foot. The author mentions famous or unrecognized amputated men, describing significant events.

  15. Sources of lead exposure in Mexico City

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Romieu, I.; Palazuelos, E.; Cahero, G.

    Many countries, including Mexico, are facing a largely unrecognized epidemic of low-level lead poisoning. Mexico is the sixth largest lead-producing country in the world, and 40% of its production is used locally in different industrial processes that cause lead contamination of the environment. The major sources and pathways of lead exposure among the Mexican population are gasoline emissions, lead-glazed ceramics, leaded paint, and lead in canned foods and beverages. In this paper we present evidence for the presence of lead in different environmental media and its impact on blood lead levels of the Mexican population. Although during the last fewmore » years important measures have been implemented problem in Mexico. There is an urgent need for regulatory policies that implement stricter control to protect the Mexican Population. There is also a need to develop adequate programs to reduce the lead burden and the associated health effects in the population that has been chronically exposed. 37 refs., 1 fig., 8 tabs.« less

  16. Biological and Organic Chemical Decomposition of Silicates. Chapter 7.2

    NASA Technical Reports Server (NTRS)

    Silverman, M. P.

    1979-01-01

    The weathering of silicate rocks and minerals, an important concern of geologists and geochemists for many years, traditionally has been approached from strictly physical and chemical points of view. Biological effects were either unrecognized, ignored, or were mentioned in passing to account for such phenomena as the accumulation of organic matter in sediments or the generation of reducing environments. A major exception occurred in soil science where agricultural scientists, studying the factors important in the development of soils and their ability to nourish and sustain various crops, laid the foundation for much of what is known of the biological breakdown of silicate rocks and minerals. The advent of the space age accelerated the realization that many environmental problems and geo- chemical processes on Earth can only be understood in terms of ecosystems. This in turn, spurred renewed interest and activity among modem biologists, geologists and soil scientists attempting to unravel the intimate relations between biology and the weathering of silicate rocks and minerals of the earth surface.

  17. Biological and Organic Chemical Decomposition of Silicates. Chapter 7.2

    NASA Technical Reports Server (NTRS)

    Sliverman, M. P.

    1979-01-01

    The weathering of silicate rocks and minerals, an important concern of geologists and geochemists for many years, traditionally has been approached from strictly physical and chemical points of view. Biological effects were either unrecognized, ignored, or were mentioned in passing to account for such phenomena as the accumulation of organic matter in sediments or the generation of reducing environments. A major exception occurred in soil science where agricultural scientists, studying the factors important in the development of soils and their ability to nourish and sustain various crops, laid the foundation for much of what is known of the biological breakdown of silicate rocks and minerals. The advent of the space age accelerated the realization that many environmental problems and geochemical processes on Earth can only be understood in terms of ecosystems. This in turn, spurred renewed interest and activity among modem biologists, geologists and soil scientists attempting to unravel the intimate relations between biology and the weathering of silicate rocks and minerals of the earth's surface.

  18. Dietary Treatment Options for Depression among Diabetic Patient, Focusing on Macronutrients

    PubMed Central

    Azadbakht, Leila

    2013-01-01

    There is a bidirectional adverse association between diabetes and depression. The odds for experiencing depressive symptoms in diabetic patients are two times more than nondiabetic persons, and depression is an independent predictor for the onset of diabetes. However, depression has been approximately unrecognized and untreated in two-thirds of diabetic patients, which may lead to worsened diabetes complications. A cornerstone strategy for managing depression among diabetic patients is the use of diet to improve both health problems. Because of similar pathophysiology for chronic diseases and depression, it seems that similar dietary recommendations could be useful. However, few studies have been conducted among diabetic patients. Regarding the complications of diabetes such as renal diseases and coronary heart diseases, the proper range of various macronutrients should be clarified in depressed diabetic patients as well as the proper type of each macronutrient. In this paper, we reviewed the available data on the treatment of depression in diabetic patients. PMID:24199205

  19. Remote monitoring of the earthquake cycle using satellite radar interferometry.

    PubMed

    Wright, Tim J

    2002-12-15

    The earthquake cycle is poorly understood. Earthquakes continue to occur on previously unrecognized faults. Earthquake prediction seems impossible. These remain the facts despite nearly 100 years of intensive study since the earthquake cycle was first conceptualized. Using data acquired from satellites in orbit 800 km above the Earth, a new technique, radar interferometry (InSAR), has the potential to solve these problems. For the first time, detailed maps of the warping of the Earth's surface during the earthquake cycle can be obtained with a spatial resolution of a few tens of metres and a precision of a few millimetres. InSAR does not need equipment on the ground or expensive field campaigns, so it can gather crucial data on earthquakes and the seismic cycle from some of the remotest areas of the planet. In this article, I review some of the remarkable observations of the earthquake cycle already made using radar interferometry and speculate on breakthroughs that are tantalizingly close.

  20. Invariant U2 snRNA nucleotides form a stem loop to recognize the intron early in splicing

    PubMed Central

    Perriman, Rhonda; Ares, Manuel

    2010-01-01

    U2 snRNA-intron branchpoint pairing is a critical step in pre-mRNA recognition by the splicing apparatus, but the mechanism by which these two RNAs engage each other is unknown. Here we identify a new U2 snRNA structure, the branchpoint interaction stem-loop (BSL), that presents the U2 nucleotides that will contact the intron. We provide evidence that the BSL forms prior to interaction with the intron, and is disrupted by the DExD/H protein Prp5p during engagement of the snRNA with the intron. In vitro splicing complex assembly in a BSL-destabilized mutant extract suggests that the BSL is required at a previously unrecognized step between commitment complex and prespliceosome formation. The extreme evolutionary conservation of the BSL suggests it represents an ancient structural solution to the problem of intron branchpoint recognition by dynamic RNA elements that must serve multiple functions at other times during splicing. PMID:20471947

  1. Sources of lead exposure in Mexico City.

    PubMed

    Romieu, I; Palazuelos, E; Hernandez Avila, M; Rios, C; Muñoz, I; Jimenez, C; Cahero, G

    1994-04-01

    Many countries, including Mexico, are facing a largely unrecognized epidemic of low-level lead poisoning. Mexico is the sixth largest lead-producing country in the world, and 40% of its production is used locally in different industrial processes that cause lead contamination of the environment. The major sources and pathways of lead exposure among the Mexican population are gasoline emissions, lead-glazed ceramics, leaded paint, and lead in canned foods and beverages. In this paper we present evidence for the presence of lead in different environmental media and its impact on blood lead levels of the Mexican population. Although during the last few years important measures have been implemented to decrease lead exposure, our findings suggest that lead poisoning is still an important problem in Mexico. There is an urgent need for regulatory policies that implement stricter control to protect the Mexican population. There is also a need to develop adequate programs to reduce the lead burden and the associated health effects in the population that has been chronically exposed.

  2. Moment of Inertia: Psychophysical Study of an Overlooked Sensation.

    ERIC Educational Resources Information Center

    Science, 1979

    1979-01-01

    This article describes the distribution of mass in a hand-held object as a fundamental but unrecognized contributor to the sensation one receives from the object. Experiments producing fractions for human sensitivity are given. (SA)

  3. Unrecognized Subclinical Infection with Tickborne Encephalitis Virus, Japan

    PubMed Central

    Yoshii, Kentaro; Kojima, Reiji

    2017-01-01

    During early 2017, we conducted a seroepidemiologic investigation for tickborne encephalitis virus among 291 Japan Self-Defense Forces members in Hokkaido. Two (0.7%) tested positive. Neither had clinically apparent symptoms after removing ticks. PMID:28930025

  4. New technologies, human-microbe interactions, and the search for previously unrecognized pathogens.

    PubMed

    Relman, David A

    2002-12-01

    Evidence suggests that a significant number of clinically important microbial pathogens remain unrecognized. Observations from the natural world, from patterns of disease in human populations, from the bedside, and from the clinical laboratory all contribute to this body of evidence. A variety of acute and chronic neurologic syndromes illustrate this point; despite features of infection, most cases of aseptic meningitis, encephalitis, and cerebral vasculitis cannot be assigned a microbiologic diagnosis. The development and clinical application of molecular methods have led to the discovery of novel members of the endogenous normal flora as well as putative disease agents. Current challenges include the establishment of criteria for disease causation and further characterization of the human microbiome during states of health. These challenges and the goal of understanding microbial contributions to inflammatory disease may be addressed effectively through the thoughtful integration of modern technologies and clinical insight.

  5. Hypertension among Oral Contraceptive Users in El Paso, Texas

    PubMed Central

    White, Kari; Potter, Joseph E.; Hopkins, Kristine; Amastae, Jon; Grossman, Daniel

    2015-01-01

    On the U.S.-Mexico border, residents frequently cross into Mexico to obtain medications or medical care. We previously reported relatively high prevalence of hypertension among Latina oral contraceptive users in El Paso, particularly those obtaining pills over the counter (OTC) in Mexico. Here, we examine factors associated with having hypertension among 411 OTC users and 399 clinic users. We also assess hypertension awareness and interest in using blood pressure kiosks. Women age 35 to 44 and who had BMI ≥ 30 kg/m2 had higher odds of having hypertension. 59% of hypertensive women had unrecognized hypertension, and 77% of all participants would use a blood pressure kiosk; there were no significant differences between clinic and OTC users. Alternative approaches to increase access to health screenings are needed in this setting, where OTC pill use among women with unrecognized hypertension confers unique health risks. PMID:24185148

  6. Unrecognized "AIDS" in Monkeys, 1969-1980: Explanations and Implications.

    PubMed

    Hammett, Theodore M; Bronson, Roderick T

    2016-06-01

    AIDS was recognized in humans in 1981 and a simian form was described in the years 1983 to 1985. However, beginning in the late 1960s, outbreaks of opportunistic infections of AIDS were seen in monkeys in the United States. This apparent syndrome went unrecognized at the time. We have assembled those early cases in monkeys and offer reasons why they did not result in earlier recognition of simian or human AIDS, including weaknesses in understanding disease mechanisms, absence of evidence of human retroviruses, and a climate of opinion that devalued investigation of infectious disease and immunologic origins of disease. The "epistemological obstacle" explains important elements of this history in that misconceptions blocked understanding of the dependent relationship among viral infection, immunodeficiency, and opportunistic diseases. Had clearer understanding of the evidence from monkeys allowed human AIDS to be recognized earlier, life-saving prevention and treatment interventions might have been implemented sooner.

  7. The pupil as an indicator of unconscious memory: Introducing the pupil priming effect.

    PubMed

    Gomes, Carlos Alexandre; Montaldi, Daniela; Mayes, Andrew

    2015-06-01

    We explored whether object behavioral priming and pupil changes occur in the absence of recognition memory. Experiment 1 found behavioral priming for unrecognized objects (Ms) regardless of whether they had been encoded perceptually or conceptually. Using the same perceptual encoding task, Experiment 2 showed greater pupil dilation for Ms than for correct rejections of unstudied objects (CRs) when reaction times were matched. In Experiment 3, there was relatively less pupil dilation for Ms than for similarly matched CRs when objects had been encoded conceptually. Mean/peak pupil dilation for CRs, but not Ms, increased in Experiment 3, in which novelty expectation was also reduced, and the pupillary time course for both Ms and CRs was distinct in the two experiments. These findings indicate that both behavioral and pupil memory occur for studied, but unrecognized stimuli, and suggest that encoding and novelty expectation modulate pupillary memory responses. © 2015 Society for Psychophysiological Research.

  8. Tendon Disorders After Total Hip Arthroplasty: Evaluation and Management.

    PubMed

    Capogna, Brian M; Shenoy, Kartik; Youm, Thomas; Stuchin, Steven A

    2017-10-01

    Most patients who undergo total hip arthroplasty are very satisfied with their outcomes. However, there is a small subset of patients who have persistent pain after surgery. The etiology of pain after total hip arthroplasty varies widely; however, tendon disorders are a major cause of debilitating pain that often go unrecognized. We performed a literature review to identify the most common tendon pathologies after total hip arthroplasty which include iliopsoas tendinitis, greater trochanteric pain syndrome, snapping hip syndrome, and abductor tendinopathy. We present a simplified approach highlighting the presentation and management of patients with suspected tendinopathies after total hip arthroplasty. These tendinopathies are treatable, and management begins with nonoperative modalities; however, in cases not responsive to conservative management, operative intervention may be necessary. Tendinopathies after total hip arthroplasty sometimes go unrecognized but when treated can result in higher surgeon and patient satisfaction. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. [Biometric method for the description of the head of an unrecognized corpse for the purpose of personality individualization and identification].

    PubMed

    Zviagin, V N; Galitskaia, O I; Negasheva, M A

    2012-01-01

    We have determined absolute dimensions of the head and the relationship between the dimensions of its selected parts. The study enrolled adult subjects (mostly of Russian ethnicity) at the age from 17 to 22 years (1108 men and 1153 women). We calculated the normal values for the estimation of real dimensional characteristics and the frequency of their occurrence in the population. The proposed approach makes it possible to reliably identify the dimensional features of human appearance in terms of the quantitative verbal description (categories 1-5) and to reveal its most characteristic features. The results of this biometric study of the heads of unrecognized corpses obtained by the specially developed technology may be used in operational and search investigations, in the procedure of corpse identification, and forensic medical personality identification of a missing subject.

  10. Unrecognized “AIDS” in Monkeys, 1969–1980: Explanations and Implications

    PubMed Central

    Bronson, Roderick T.

    2016-01-01

    AIDS was recognized in humans in 1981 and a simian form was described in the years 1983 to 1985. However, beginning in the late 1960s, outbreaks of opportunistic infections of AIDS were seen in monkeys in the United States. This apparent syndrome went unrecognized at the time. We have assembled those early cases in monkeys and offer reasons why they did not result in earlier recognition of simian or human AIDS, including weaknesses in understanding disease mechanisms, absence of evidence of human retroviruses, and a climate of opinion that devalued investigation of infectious disease and immunologic origins of disease. The “epistemological obstacle” explains important elements of this history in that misconceptions blocked understanding of the dependent relationship among viral infection, immunodeficiency, and opportunistic diseases. Had clearer understanding of the evidence from monkeys allowed human AIDS to be recognized earlier, life-saving prevention and treatment interventions might have been implemented sooner. PMID:27077355

  11. Environmental hazards of waste disposal patterns--a multimethod study in an unrecognized Bedouin village in the Negev area of Israel.

    PubMed

    Meallem, Ilana; Garb, Yaakov; Cwikel, Julie

    2010-01-01

    The Bedouin of the Negev region of Israel are a formerly nomadic, indigenous, ethnic minority, of which 40% currently live in unrecognized villages without organized, solid waste disposal. This study, using both quantitative and qualitative methods, explored the transition from traditional rubbish production and disposal to current uses, the current composition of rubbish, methods of waste disposal, and the extent of exposure to waste-related environmental hazards in the village of Um Batim. The modern, consumer lifestyle produced both residential and construction waste that was dumped very close to households. Waste was tended to by women who predominantly used backyard burning for disposal, exposing villagers to corrosive, poisonous, and dangerously flammable items at these burn sites. Village residents expressed a high level of concern over environmental hazards, yet no organized waste disposal or environmental hazards reduction was implemented.

  12. Analytical performances of food microbiology laboratories - critical analysis of 7 years of proficiency testing results.

    PubMed

    Abdel Massih, M; Planchon, V; Polet, M; Dierick, K; Mahillon, J

    2016-02-01

    Based on the results of 19 food microbiology proficiency testing (PT) schemes, this study aimed to assess the laboratory performances, to highlight the main sources of unsatisfactory analytical results and to suggest areas of improvement. The 2009-2015 results of REQUASUD and IPH PT, involving a total of 48 laboratories, were analysed. On average, the laboratories failed to detect or enumerate foodborne pathogens in 3·0% of the tests. Thanks to a close collaboration with the PT participants, the causes of outliers could be identified in 74% of the cases. The main causes of erroneous PT results were either pre-analytical (handling of the samples, timing of analysis), analytical (unsuitable methods, confusion of samples, errors in colony counting or confirmation) or postanalytical mistakes (calculation and encoding of results). PT schemes are a privileged observation post to highlight analytical problems, which would otherwise remain unnoticed. In this perspective, this comprehensive study of PT results provides insight into the sources of systematic errors encountered during the analyses. This study draws the attention of the laboratories to the main causes of analytical errors and suggests practical solutions to avoid them, in an educational purpose. The observations support the hypothesis that regular participation to PT, when followed by feed-back and appropriate corrective actions, can play a key role in quality improvement and provide more confidence in the laboratory testing results. © 2015 The Society for Applied Microbiology.

  13. Modifications of haematology analyzers to improve cell counting and leukocyte differentiating in cerebrospinal fluid controls of the Joint German Society for Clinical Chemistry and Laboratory Medicine.

    PubMed

    Kleine, Tilmann O; Nebe, C Thomas; Löwer, Christa; Lehmitz, Reinhard; Kruse, Rolf; Geilenkeuser, Wolf-Jochen; Dorn-Beineke, Alexandra

    2009-08-01

    Flow cytometry (FCM) is used with haematology analyzers (HAs) to count cells and differentiate leukocytes in cerebrospinal fluid (CSF). To evaluate the FCM techniques of HAs, 10 external DGKL trials with CSF controls were carried out in 2004 to 2008. Eight single platform HAs with and without CSF equipment were evaluated with living blood leukocytes and erythrocytes in CSF like DGKL controls: Coulter (LH750,755), Abbott CD3200, CD3500, CD3700, CD4000, Sapphire, ADVIA 120(R) CSF assay, and Sysmex XE-2100(R). Results were compared with visual counting of native cells in Fuchs-Rosenthal chamber, unstained, and absolute values of leukocyte differentiation, assayed by dual platform analysis with immune-FCM (FACSCalibur, CD45, CD14) and the chamber counts. Reference values X were compared with HA values Y by statistical evaluation with Passing/Bablock (P/B) linear regression analysis to reveal conformity of both methods. The HAs, studied, produced no valid results with DGKL CSF controls, because P/B regression revealed no conformity with the reference values due to:-blank problems with impedance analysis,-leukocyte loss with preanalytical erythrocyte lysis procedures, especially of monocytes,-inaccurate results with ADVIA cell sphering and cell differentiation with algorithms and enzyme activities (e.g., peroxidase). HA techniques have to be improved, e.g., using no erythrocyte lysis and CSF adequate techniques, to examine CSF samples precise and accurate. Copyright 2009 International Society for Advancement of Cytometry.

  14. Tracing a roadmap for vitamin B₁₂ testing using the health technology assessment approach.

    PubMed

    Ferraro, Simona; Mozzi, Roberta; Panteghini, Mauro

    2014-06-01

    In our hospital, we are currently working to manage the appropriateness of vitamin B₁₂ (B12) testing. Unfortunately, the classic evidence-based approach is unhelpful in this process and meta-analyzing data on the accuracy of this marker for cobalamin deficiency detection is misleading due to the lack of reference diagnostic methods. The approach currently proposed by the Health Technology Assessment (HTA) enables us to tackle the issue of B₁₂ requests as a "healthcare" problem by considering the position of stakeholders involved in ordering, performing, interpreting the test, and receiving its results. Clinical expectations, methodological issues, and ethical aspects concerning the performance of the test can aid us in providing more guidance on the use of this marker. By building such structured information, hemodialysis patients and pregnant women have emerged as those groups preferentially requiring B₁₂ testing, as it may potentially improve the clinical outcome. To avoid misinterpretation of B₁₂ results more care should be taken in considering its biochemical and biological features, as well as the analytical issues. Spurious values obtained by current automated immunoassays may reflect suboptimal pre-analytical steps as well as known interfering conditions. Furthermore, the harmonization of results by available methods is still a far-reaching goal and the approach to interpret an individual's results should be improved. Tracing a roadmap for B₁₂ testing by exploiting the HTA model to balance the stakeholders' claims and maximizing the patient's outcome may help to manage the marker demand.

  15. Clinically unrecognized miliary tuberculosis: an autopsy study.

    PubMed

    Savic, Ivana; Trifunovic-Skodric, Vesna; Mitrovic, Dragan

    2016-01-01

    Miliary tuberculosis (TB) usually presents with atypical clinical manifestations; thus it is often recognized only at autopsy. Our objectives were to study the frequency of MT diagnosed at autopsy and determine clinical diagnoses that masked TB, as well as causes of death and comorbidities. Retrospective study of all autopsies performed between 2008 and 2014. Institute of Pathology, Belgrade, Serbia. in subjects where autopsy showed the presence of MT that was not recognized clinically, we recorded the clinical diagnoses (presumed causes of death) as reported in autopsy request forms, as well as actual cause of death and comorbidities as determined at autopsy. Clinically unrecognized MT. The total number of autopsies in this period was 6206. thirty-five individuals showed clinically unrecognized MT (0.56% of all autopsies, age: 62.2 [17.2] years, M:F=2:3). Common clinical diagnoses masking pulmonary MT were exacerbation of COPD (25%) and pulmonary thromboembolism (25%), with common radiological presentation of diffuse pulmonary infiltrates (56.3%). Dominant clinical diagnoses in patients with generalized MT were adult respiratory distress syndrome, sepsis, gastrointestinal bleeding and meningoencephalitis. Disseminated MT was often associated with secondary anemia or thrombocytopenia (15.8%) and recent surgery (15.8%). Frequent comorbidities included chronic renal failure and malignancies, whereas MT was a dominant cause of death. Greater awareness of MT is needed to improve recognition in clinical settings. In particular, MT should be considered in patients with atypical clinical presentation and diffuse pulmonary infiltrates on chest X-ray, particularly if they have chronic renal failure, malignancy, hematological disorders or a history of recent surgery. None.

  16. Sleep problems in Dravet syndrome: a modifiable comorbidity.

    PubMed

    Licheni, Shane H; Mcmahon, Jacinta M; Schneider, Amy L; Davey, Margot J; Scheffer, Ingrid E

    2018-02-01

    Many children with severe developmental and epileptic encephalopathies experience significant sleep disturbance, causing major disruption to the family's quality of life. We aimed to determine the frequency and nature of sleep problems in individuals with Dravet syndrome. The Sleep Disturbance Scale for Children and a seizure questionnaire were distributed to the parents/guardians of 96 patients with Dravet syndrome. Sixteen patients had two nights of home oximetry. Fifty-seven out of 96 questionnaires were completed. Forty-three out of 57 (75%) individuals had sleep problems. Twenty-five out of 57 (44%) individuals had an abnormal total sleep score, with difficulty initiating and maintaining sleep (22 out of 57, 39%), sleep-wake transition disorders (20 out of 57, 35%), and sleep breathing disorders (19 out of 57, 33%). Twenty-two out of 57 (39%) individuals took medication to assist sleep, predominantly melatonin (n=14). Thirty out of 57 (53%) recently had nocturnal seizures. Overnight oximetry showed 14 out of 16 (88%) had a higher oxygen desaturation index (>3%), and six out of 16 (38%) had higher mean pulse rates than normative values. Home oximetry was normal or inconclusive in all patients. Seventy-five per cent of individuals with Dravet syndrome had sleep problems, highlighting the importance of routinely assessing sleep and initiating appropriate behavioural and pharmacological interventions to improve the patient and family's quality of life. A high oxygen desaturation index and mean pulse rates on pulse oximetry may reflect unrecognized nocturnal seizures. More than 70% of patients with Dravet syndrome have sleep problems. Difficulty initiating and maintaining sleep was most common, particularly in those older than 20 years. Second most common were sleep-wake transition disorders, affecting more than 50% of those younger than 5 years. Sleep breathing disorders were a frequent problem across all age groups. Oximetry was not diagnostic of sleep-disordered breathing or obvious seizures. © 2017 Mac Keith Press.

  17. Flow cytometry for feline lymphoma: a retrospective study regarding pre-analytical factors possibly affecting the quality of samples.

    PubMed

    Martini, Valeria; Bernardi, Serena; Marelli, Priscilla; Cozzi, Marzia; Comazzi, Stefano

    2018-06-01

    Objectives Flow cytometry (FC) is becoming increasingly popular among veterinary oncologists for the diagnosis of lymphoma or leukaemia. It is accurate, fast and minimally invasive. Several studies of FC have been carried out in canine oncology and applied with great results, whereas there is limited knowledge and use of this technique in feline patients. This is mainly owing to the high prevalence of intra-abdominal lymphomas in this species and the difficulty associated with the diagnostic procedures needed to collect the sample. The purpose of the present study is to investigate whether any pre-analytical factor might affect the quality of suspected feline lymphoma samples for FC analysis. Methods Ninety-seven consecutive samples of suspected feline lymphoma were retrospectively selected from the authors' institution's FC database. The referring veterinarians were contacted and interviewed about several different variables, including signalment, appearance of the lesion, features of the sampling procedure and the experience of veterinarians performing the sampling. Statistical analyses were performed to assess the possible influence of these variables on the cellularity of the samples and the likelihood of it being finally processed for FC. Results Sample cellularity is a major factor in the likelihood of the sample being processed. Moreover, sample cellularity was significantly influenced by the needle size, with 21 G needles providing the highest cellularity. Notably, the sample cellularity and the likelihood of being processed did not vary between peripheral and intra-abdominal lesions. Approximately half of the cats required pharmacological restraint. Side effects were reported in one case only (transient swelling after peripheral lymph node sampling). Conclusions and relevance FC can be safely applied to cases of suspected feline lymphomas, including intra-abdominal lesions. A 21 G needle should be preferred for sampling. This study provides the basis for the increased use of this minimally invasive, fast and cost-effective technique in feline medicine.

  18. Reproducibility of Interferon Gamma (IFN-γ) Release Assays. A Systematic Review

    PubMed Central

    Tagmouti, Saloua; Slater, Madeline; Benedetti, Andrea; Kik, Sandra V.; Banaei, Niaz; Cattamanchi, Adithya; Metcalfe, John; Dowdy, David; van Zyl Smit, Richard; Dendukuri, Nandini

    2014-01-01

    Rationale: Interferon gamma (IFN-γ) release assays for latent tuberculosis infection result in a larger-than-expected number of conversions and reversions in occupational screening programs, and reproducibility of test results is a concern. Objectives: Knowledge of the relative contribution and extent of the individual sources of variability (immunological, preanalytical, or analytical) could help optimize testing protocols. Methods: We performed a systematic review of studies published by October 2013 on all potential sources of variability of commercial IFN-γ release assays (QuantiFERON-TB Gold In-Tube and T-SPOT.TB). The included studies assessed test variability under identical conditions and under different conditions (the latter both overall and stratified by individual sources of variability). Linear mixed effects models were used to estimate within-subject SD. Measurements and Main Results: We identified a total of 26 articles, including 7 studies analyzing variability under the same conditions, 10 studies analyzing variability with repeat testing over time under different conditions, and 19 studies reporting individual sources of variability. Most data were on QuantiFERON (only three studies on T-SPOT.TB). A considerable number of conversions and reversions were seen around the manufacturer-recommended cut-point. The estimated range of variability of IFN-γ response in QuantiFERON under identical conditions was ±0.47 IU/ml (coefficient of variation, 13%) and ±0.26 IU/ml (30%) for individuals with an initial IFN-γ response in the borderline range (0.25–0.80 IU/ml). The estimated range of variability in noncontrolled settings was substantially larger (±1.4 IU/ml; 60%). Blood volume inoculated into QuantiFERON tubes and preanalytic delay were identified as key sources of variability. Conclusions: This systematic review shows substantial variability with repeat IFN-γ release assays testing even under identical conditions, suggesting that reversions and conversions around the existing cut-point should be interpreted with caution. PMID:25188809

  19. Pre-Analytical Conditions in Non-Invasive Prenatal Testing of Cell-Free Fetal RHD

    PubMed Central

    Rieneck, Klaus; Krog, Grethe Risum; Nielsen, Leif Kofoed; Tabor, Ann; Dziegiel, Morten Hanefeld

    2013-01-01

    Background Non-invasive prenatal testing of cell-free fetal DNA (cffDNA) in maternal plasma can predict the fetal RhD type in D negative pregnant women. In Denmark, routine antenatal screening for the fetal RhD gene (RHD) directs the administration of antenatal anti-D prophylaxis only to women who carry an RhD positive fetus. Prophylaxis reduces the risk of immunization that may lead to hemolytic disease of the fetus and the newborn. The reliability of predicting the fetal RhD type depends on pre-analytical factors and assay sensitivity. We evaluated the testing setup in the Capital Region of Denmark, based on data from routine antenatal RHD screening. Methods Blood samples were drawn at gestational age 25 weeks. DNA extracted from 1 mL of plasma was analyzed for fetal RHD using a duplex method for exon 7/10. We investigated the effect of blood sample transportation time (n = 110) and ambient outdoor temperatures (n = 1539) on the levels of cffDNA and total DNA. We compared two different quantification methods, the delta Ct method and a universal standard curve. PCR pipetting was compared on two systems (n = 104). Results The cffDNA level was unaffected by blood sample transportation for up to 9 days and by ambient outdoor temperatures ranging from -10°C to 28°C during transport. The universal standard curve was applicable for cffDNA quantification. Identical levels of cffDNA were observed using the two automated PCR pipetting systems. We detected a mean of 100 fetal DNA copies/mL at a median gestational age of 25 weeks (range 10–39, n = 1317). Conclusion The setup for real-time PCR-based, non-invasive prenatal testing of cffDNA in the Capital Region of Denmark is very robust. Our findings regarding the transportation of blood samples demonstrate the high stability of cffDNA. The applicability of a universal standard curve facilitates easy cffDNA quantification. PMID:24204719

  20. EC4 European Syllabus for Post-Graduate Training in Clinical Chemistry and Laboratory Medicine: version 3 - 2005.

    PubMed

    Zerah, Simone; McMurray, Janet; Bousquet, Bernard; Baum, Hannsjorg; Beastall, Graham H; Blaton, Vic; Cals, Marie-Josèphe; Duchassaing, Danielle; Gaudeau-Toussaint, Marie-Françoise; Harmoinen, Aimo; Hoffmann, Hans; Jansen, Rob T; Kenny, Desmond; Kohse, Klaus P; Köller, Ursula; Gobert, Jean-Gérard; Linget, Christine; Lund, Erik; Nubile, Giuseppe; Opp, Matthias; Pazzagli, Mario; Pinon, Georges; Queralto, José M; Reguengo, Henrique; Rizos, Demetrios; Szekeres, Thomas; Vidaud, Michel; Wallinder, Hans

    2006-01-01

    The EC4 Syllabus for Postgraduate Training is the basis for the European Register of Specialists in Clinical Chemistry and Laboratory Medicine. The syllabus: Indicates the level of requirements in postgraduate training to harmonise the postgraduate education in the European Union (EU); Indicates the level of content of national training programmes to obtain adequate knowledge and experience; Is approved by all EU societies for clinical chemistry and laboratory medicine. The syllabus is not primarily meant to be a training guide, but on the basis of the overview given (common minimal programme), national societies should formulate programmes that indicate where knowledge and experience is needed. The main points of this programme are: Indicates the level of requirements in postgraduate training to harmonise the postgraduate education in the European Union (EU); Indicates the level of content of national training programmes to obtain adequate knowledge and experience; Is approved by all EU societies for clinical chemistry and laboratory medicine. Knowledge in biochemistry, haematology, immunology, etc.; Pre-analytical conditions; Evaluation of results; Interpretations (post-analytical phase); Laboratory management; and Quality insurance management. The aim of this version of the syllabus is to be in accordance with the Directive of Professional Qualifications published on 30 September 2005. To prepare the common platforms planned in this directive, the disciplines are divided into four categories: Indicates the level of requirements in postgraduate training to harmonise the postgraduate education in the European Union (EU); Indicates the level of content of national training programmes to obtain adequate knowledge and experience; Is approved by all EU societies for clinical chemistry and laboratory medicine. Knowledge in biochemistry, haematology, immunology, etc.; Pre-analytical conditions; Evaluation of results; Interpretations (post-analytical phase); Laboratory management; and Quality insurance management. General chemistry, encompassing biochemistry, endocrinology, chemical (humoral), immunology, toxicology, and therapeutic drug monitoring; Haematology, covering cells, transfusion serology, coagulation, and cellular immunology; Microbiology, involving bacteriology, virology, parasitology, and mycology; Genetics and IVF.

  1. A New Approach to Standardize Multicenter Studies: Mobile Lab Technology for the German Environmental Specimen Bank

    PubMed Central

    Lermen, Dominik; Schmitt, Daniel; Bartel-Steinbach, Martina; Schröter-Kermani, Christa; Kolossa-Gehring, Marike; von Briesen, Hagen; Zimmermann, Heiko

    2014-01-01

    Technical progress has simplified tasks in lab diagnosis and improved quality of test results. Errors occurring during the pre-analytical phase have more negative impact on the quality of test results than errors encountered during the total analytical process. Different infrastructures of sampling sites can highly influence the quality of samples and therewith of analytical results. Annually the German Environmental Specimen Bank (ESB) collects, characterizes, and stores blood, plasma, and urine samples of 120–150 volunteers each on four different sampling sites in Germany. Overarching goal is to investigate the exposure to environmental pollutants of non-occupational exposed young adults combining human biomonitoring with questionnaire data. We investigated the requirements of the study and the possibility to realize a highly standardized sampling procedure on a mobile platform in order to increase the required quality of the pre-analytical phase. The results lead to the development of a mobile epidemiologic laboratory (epiLab) in the project “Labor der Zukunft” (future’s lab technology). This laboratory includes a 14.7 m2 reception area to record medical history and exposure-relevant behavior, a 21.1 m2 examination room to record dental fillings and for blood withdrawal, a 15.5 m2 biological safety level 2 laboratory to process and analyze samples on site including a 2.8 m2 personnel lock and a 3.6 m2 cryofacility to immediately freeze samples. Frozen samples can be transferred to their final destination within the vehicle without breaking the cold chain. To our knowledge, we herewith describe for the first time the implementation of a biological safety laboratory (BSL) 2 lab and an epidemiologic unit on a single mobile platform. Since 2013 we have been collecting up to 15.000 individual human samples annually under highly standardized conditions using the mobile laboratory. Characterized and free of alterations they are kept ready for retrospective analyses in their final archive, the German ESB. PMID:25141120

  2. Preanalytical variables and phosphoepitope expression in FFPE tissue: quantitative epitope assessment after variable cold ischemic time.

    PubMed

    Vassilakopoulou, Maria; Parisi, Fabio; Siddiqui, Summar; England, Allison M; Zarella, Elizabeth R; Anagnostou, Valsamo; Kluger, Yuval; Hicks, David G; Rimm, David L; Neumeister, Veronique M

    2015-03-01

    Individualized targeted therapies for cancer patients require accurate and reproducible assessment of biomarkers to be able to plan treatment accordingly. Recent studies have shown highly variable effects of preanalytical variables on gene expression profiling and protein levels of different tissue types. Several publications have described protein degradation of tissue samples as a direct result of delay of formalin fixation of the tissue. Phosphorylated proteins are more labile and epitope degradation can happen within 30 min of cold ischemic time. To address this issue, we evaluated the change in antigenicity of a series of phosphoproteins in paraffin-embedded samples from breast tumors as a function of time to formalin fixation. A tissue microarray consisting of 93 breast cancer specimens with documented time-to-fixation was used to evaluate changes in antigenicity of 12 phosphoepitopes frequently used in research settings as a function of cold ischemic time. Analysis was performed in a quantitative manner using the AQUA technology for quantitative immunofluorescence. For each marker, least squares univariate linear regression was performed and confidence intervals were computed using bootstrapping. The majority of the epitopes tested revealed changes in expression levels with increasing time to formalin fixation. Some phosphorylated proteins, such as phospho-HSP27 and phospho-S6 RP, involved in post-translational modification and stress response pathways increased in expression or phosphorylation levels. Others (like phospho-AKT, phosphor-ERK1/2, phospho-Tyrosine, phospho-MET, and others) are quite labile and loss of antigenicity can be reported within 1-2 h of cold ischemic time. Therefore specimen collection should be closely monitored and subjected to quality control measures to ensure accurate measurement of these epitopes. However, a few phosphoepitopes (like phospho-JAK2 and phospho-ER) are sufficiently robust for routine usage in companion diagnostic testing.

  3. Optimization of analytical and pre-analytical conditions for MALDI-TOF-MS human urine protein profiles.

    PubMed

    Calvano, C D; Aresta, A; Iacovone, M; De Benedetto, G E; Zambonin, C G; Battaglia, M; Ditonno, P; Rutigliano, M; Bettocchi, C

    2010-03-11

    Protein analysis in biological fluids, such as urine, by means of mass spectrometry (MS) still suffers for insufficient standardization in protocols for sample collection, storage and preparation. In this work, the influence of these variables on healthy donors human urine protein profiling performed by matrix assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS) was studied. A screening of various urine sample pre-treatment procedures and different sample deposition approaches on the MALDI target was performed. The influence of urine samples storage time and temperature on spectral profiles was evaluated by means of principal component analysis (PCA). The whole optimized procedure was eventually applied to the MALDI-TOF-MS analysis of human urine samples taken from prostate cancer patients. The best results in terms of detected ions number and abundance in the MS spectra were obtained by using home-made microcolumns packed with hydrophilic-lipophilic balance (HLB) resin as sample pre-treatment method; this procedure was also less expensive and suitable for high throughput analyses. Afterwards, the spin coating approach for sample deposition on the MALDI target plate was optimized, obtaining homogenous and reproducible spots. Then, PCA indicated that low storage temperatures of acidified and centrifuged samples, together with short handling time, allowed to obtain reproducible profiles without artifacts contribution due to experimental conditions. Finally, interesting differences were found by comparing the MALDI-TOF-MS protein profiles of pooled urine samples of healthy donors and prostate cancer patients. The results showed that analytical and pre-analytical variables are crucial for the success of urine analysis, to obtain meaningful and reproducible data, even if the intra-patient variability is very difficult to avoid. It has been proven how pooled urine samples can be an interesting way to make easier the comparison between healthy and pathological samples and to individuate possible differences in the protein expression between the two sets of samples. Copyright 2009 Elsevier B.V. All rights reserved.

  4. Pre-analytical conditions in non-invasive prenatal testing of cell-free fetal RHD.

    PubMed

    Clausen, Frederik Banch; Jakobsen, Tanja Roien; Rieneck, Klaus; Krog, Grethe Risum; Nielsen, Leif Kofoed; Tabor, Ann; Dziegiel, Morten Hanefeld

    2013-01-01

    Non-invasive prenatal testing of cell-free fetal DNA (cffDNA) in maternal plasma can predict the fetal RhD type in D negative pregnant women. In Denmark, routine antenatal screening for the fetal RhD gene (RHD) directs the administration of antenatal anti-D prophylaxis only to women who carry an RhD positive fetus. Prophylaxis reduces the risk of immunization that may lead to hemolytic disease of the fetus and the newborn. The reliability of predicting the fetal RhD type depends on pre-analytical factors and assay sensitivity. We evaluated the testing setup in the Capital Region of Denmark, based on data from routine antenatal RHD screening. Blood samples were drawn at gestational age 25 weeks. DNA extracted from 1 mL of plasma was analyzed for fetal RHD using a duplex method for exon 7/10. We investigated the effect of blood sample transportation time (n = 110) and ambient outdoor temperatures (n = 1539) on the levels of cffDNA and total DNA. We compared two different quantification methods, the delta Ct method and a universal standard curve. PCR pipetting was compared on two systems (n = 104). The cffDNA level was unaffected by blood sample transportation for up to 9 days and by ambient outdoor temperatures ranging from -10 °C to 28 °C during transport. The universal standard curve was applicable for cffDNA quantification. Identical levels of cffDNA were observed using the two automated PCR pipetting systems. We detected a mean of 100 fetal DNA copies/mL at a median gestational age of 25 weeks (range 10-39, n = 1317). The setup for real-time PCR-based, non-invasive prenatal testing of cffDNA in the Capital Region of Denmark is very robust. Our findings regarding the transportation of blood samples demonstrate the high stability of cffDNA. The applicability of a universal standard curve facilitates easy cffDNA quantification.

  5. A method to solubilise protein aggregates for immunoassay quantification which overcomes the neurofilament "hook" effect.

    PubMed

    Lu, Ching-Hua; Kalmar, Bernadett; Malaspina, Andrea; Greensmith, Linda; Petzold, Axel

    2011-02-15

    Neurofilament (Nf) aggregates are a common pathological feature of neurodegenerative disorders. Although Nf levels have been investigated as a potential disease biomarker, Nf aggregates may mask Nf epitopes, preventing accurate quantification by immunoassay. Using the SOD1(G93A) mouse model of amyotrophic lateral sclerosis, we developed a method to disrupt Nf aggregates, allowing optimal immunoassay performance. Phosphorylated (NfH(SMI35)) and hyperphosphorylated (NfH(SMI34)) Nf levels in plasma from 120-day SOD1(G93A) mice were quantified using an in-house ELISA modified for use with small volumes. Different pre-analytical methods were tested for their ability to solubilize Nf aggregates and immunoblotting was used for qualitative analysis. A 'hook effect' was observed for serially diluted plasma samples quantified using an ELISA originally developed for CSF samples. Immunoblotting confirmed the existence of high molecular-weight NfH aggregates in plasma and the resolving effect of timed urea on these aggregates. Thermostatic (pre-thawing) and chemical (calcium chelators, urea) pre-analytical processing of samples had variable success in disrupting NfH aggregates. Timed urea-calcium chelator incubation yielded the most consistent plasma NfH levels. A one hour sample pre-incubation with 0.5M urea in Barbitone-EDTA buffer at room temperature resolved the "hook effect" without compromising the ELISA. In SOD1(G93A) mice, median levels of NfH(SMI34) were over 10-fold and NfH(SMI35) levels 5-fold greater than controls. NfH aggregates can be solubilised and the "hook effect" abolished by a one-hour sample pre-incubation in a urea-calcium chelator-enriched buffer. This method is applicable for quantification of NfH phosphoforms in experimental and disease settings where Nf aggregate formation occurs. © 2010 Elsevier B.V. All rights reserved.

  6. A new approach to standardize multicenter studies: mobile lab technology for the German Environmental Specimen Bank.

    PubMed

    Lermen, Dominik; Schmitt, Daniel; Bartel-Steinbach, Martina; Schröter-Kermani, Christa; Kolossa-Gehring, Marike; von Briesen, Hagen; Zimmermann, Heiko

    2014-01-01

    Technical progress has simplified tasks in lab diagnosis and improved quality of test results. Errors occurring during the pre-analytical phase have more negative impact on the quality of test results than errors encountered during the total analytical process. Different infrastructures of sampling sites can highly influence the quality of samples and therewith of analytical results. Annually the German Environmental Specimen Bank (ESB) collects, characterizes, and stores blood, plasma, and urine samples of 120-150 volunteers each on four different sampling sites in Germany. Overarching goal is to investigate the exposure to environmental pollutants of non-occupational exposed young adults combining human biomonitoring with questionnaire data. We investigated the requirements of the study and the possibility to realize a highly standardized sampling procedure on a mobile platform in order to increase the required quality of the pre-analytical phase. The results lead to the development of a mobile epidemiologic laboratory (epiLab) in the project "Labor der Zukunft" (future's lab technology). This laboratory includes a 14.7 m(2) reception area to record medical history and exposure-relevant behavior, a 21.1 m(2) examination room to record dental fillings and for blood withdrawal, a 15.5 m(2) biological safety level 2 laboratory to process and analyze samples on site including a 2.8 m(2) personnel lock and a 3.6 m2 cryofacility to immediately freeze samples. Frozen samples can be transferred to their final destination within the vehicle without breaking the cold chain. To our knowledge, we herewith describe for the first time the implementation of a biological safety laboratory (BSL) 2 lab and an epidemiologic unit on a single mobile platform. Since 2013 we have been collecting up to 15.000 individual human samples annually under highly standardized conditions using the mobile laboratory. Characterized and free of alterations they are kept ready for retrospective analyses in their final archive, the German ESB.

  7. Preanalytic Factors Associated With Hemolysis in Emergency Department Blood Samples.

    PubMed

    Phelan, Michael P; Reineks, Edmunds Z; Schold, Jesse D; Hustey, Frederic M; Chamberlin, Janelle; Procop, Gary W

    2018-02-01

    - Hemolysis of emergency department blood samples is a common occurrence and has a negative impact on health care delivery. - To determine the effect of preanalytic factors (straight stick, intravenous [IV] line, needle gauge, location of blood draw, syringe versus vacuum tube use, tourniquet time) on hemolysis in emergency department blood samples. - A single 65 000-visit emergency department's electronic health record was queried for emergency department potassium results and blood draw technique for all samples obtained in calendar year 2014, resulting in 54 531 potassium results. Hemolyzed potassium was measured by hemolysis index. Comparisons of hemolysis by sampling technique were conducted by χ 2 tests. - Overall hemolysis was 10.0% (5439 of 54 531). Hemolysis among samples obtained from straight stick was significantly less than among those obtained with IV line (5.4% [33 of 615] versus 10.2% [4821 of 47 266], P < .001). For IV-placed blood draws, antecubital location had a statistically significant lower overall hemolysis compared with other locations: 7.4% (2117 of 28 786) versus 14.6% (2622 of 17 960) ( P < .001). For blood drawn with a syringe compared with vacuum, hemolysis was 13.0% (92 of 705) and 11.0% (1820 of 16 590), respectively ( P = .09, not significant). For large-gauge IV blood draws versus smaller-gauge IV lines, a lower hemolysis was also observed (9.3% [3882 of 41 571] versus 16.7% [939 of 5633]) ( P < .001). For IV-drawn blood with tourniquet time less than 60 seconds, hemolysis was 10.3% (1362 of 13 162) versus 13.9% for more than 60 seconds (532 of 3832), P < .001. - This study confirmed previous findings that straight stick and antecubital location are significantly associated with reduced hemolysis and indicated that shorter tourniquet time and larger gauge for IV draws were significantly associated with lower hemolysis.

  8. Increased length of inpatient stay and poor clinical coding: audit of patients with diabetes.

    PubMed

    Daultrey, Harriet; Gooday, Catherine; Dhatariya, Ketan

    2011-11-01

    People with diabetes stay in hospital for longer than those without diabetes for similar conditions. Clinical coding is poor across all specialties. Inpatients with diabetes often have unrecognized foot problems. We wanted to look at the relationships between these factors. A single day audit, looking at the prevalence of diabetes in all adult inpatients. Also looking at their feet to find out how many were high-risk or had existing problems. A 998-bed university teaching hospital. All adult inpatients. (a) To see if patients with diabetes and foot problems were in hospital for longer than the national average length of stay compared with national data; (b) to see if there were people in hospital with acute foot problems who were not known to the specialist diabetic foot team; and (c) to assess the accuracy of clinical coding. We identified 110 people with diabetes. However, discharge coding data for inpatients on that day showed 119 people with diabetes. Length of stay (LOS) was substantially higher for those with diabetes compared to those without (± SD) at 22.39 (22.26) days, vs. 11.68 (6.46) (P < 0.001). Finally, clinical coding was poor with some people who had been identified as having diabetes on the audit, who were not coded as such on discharge. Clinical coding - which is dependent on discharge summaries - poorly reflects diagnoses. Additionally, length of stay is significantly longer than previous estimates. The discrepancy between coding and diagnosis needs addressing by increasing the levels of awareness and education of coders and physicians. We suggest that our data be used by healthcare planners when deciding on future tariffs.

  9. Increased length of inpatient stay and poor clinical coding: audit of patients with diabetes

    PubMed Central

    Daultrey, Harriet; Gooday, Catherine; Dhatariya, Ketan

    2011-01-01

    Objectives People with diabetes stay in hospital for longer than those without diabetes for similar conditions. Clinical coding is poor across all specialties. Inpatients with diabetes often have unrecognized foot problems. We wanted to look at the relationships between these factors. Design A single day audit, looking at the prevalence of diabetes in all adult inpatients. Also looking at their feet to find out how many were high-risk or had existing problems. Setting A 998-bed university teaching hospital. Participants All adult inpatients. Main outcome measures (a) To see if patients with diabetes and foot problems were in hospital for longer than the national average length of stay compared with national data; (b) to see if there were people in hospital with acute foot problems who were not known to the specialist diabetic foot team; and (c) to assess the accuracy of clinical coding. Results We identified 110 people with diabetes. However, discharge coding data for inpatients on that day showed 119 people with diabetes. Length of stay (LOS) was substantially higher for those with diabetes compared to those without (± SD) at 22.39 (22.26) days, vs. 11.68 (6.46) (P < 0.001). Finally, clinical coding was poor with some people who had been identified as having diabetes on the audit, who were not coded as such on discharge. Conclusion Clinical coding – which is dependent on discharge summaries – poorly reflects diagnoses. Additionally, length of stay is significantly longer than previous estimates. The discrepancy between coding and diagnosis needs addressing by increasing the levels of awareness and education of coders and physicians. We suggest that our data be used by healthcare planners when deciding on future tariffs. PMID:22140609

  10. A Different Vision of Education.

    ERIC Educational Resources Information Center

    Nixon, Nicholas; Coles, Robert

    1999-01-01

    Presents photos featuring students from the Perkins School for the Blind (Massachusetts) reprinted from "School," a book by photographer Nicholas Nixon and psychiatrist Robert Coles. Coles says Nixon's focused, confined scenes paradoxically open viewers' minds to previously unimagined or unrecognized possibilities. Photos are accompanied…

  11. In Abundance: Networked Participatory Practices as Scholarship

    ERIC Educational Resources Information Center

    Stewart, Bonnie E.

    2015-01-01

    In an era of knowledge abundance, scholars have the capacity to distribute and share ideas and artifacts via digital networks, yet networked scholarship often remains unrecognized within institutional spheres of influence. Using ethnographic methods including participant observation, interviews, and document analysis, this study investigates…

  12. A multilocus database for the identification of Aspergillus and Penicillium species

    USDA-ARS?s Scientific Manuscript database

    Identification of Aspergillus and Penicillium isolates using phenotypic methods is increasingly complex and difficult but genetic tools allow recognition and description of species formerly unrecognized or cryptic. We constructed a web-based taxonomic database using BIGSdb for the identification of ...

  13. UNRECOGNIZED OR POTENTIAL RISK FACTORS FOR CHILDHOOD CANCER

    EPA Science Inventory

    Traditional epidemiological studies suggest that the contribution of environmental agents to childhood cancer may be minor. However, epidemiological methods can only seldom identify causal factors associated with a relative risk of less than a factor of one and a half to two. App...

  14. Utility of multiple rule out CT screening of high-risk atraumatic patients in an emergency department-a feasibility study.

    PubMed

    Pries-Heje, Mia M; Hasselbalch, Rasmus B; Raaschou, Henriette; Rezanavaz-Gheshlagh, Bijan; Heebøll, Hanne; Rehman, Shazia; Kristensen, Mariana; Andersen, Erik Henning; Ravn, Lisbet; Nèmery, Michel C; Lind, Morten N; Boel, Thomas; Ulriksen, Peter Sommer; Iversen, Kasper K

    2018-02-17

    Several large trials have evaluated the effect of CT screening based on specific symptoms, with varying outcomes. Screening of patients with CT based on their prognosis alone has not been examined before. For moderate-to-high risk patients presenting in the emergency department (ED), the potential gain from a CT scan might outweigh the risk of radiation exposure. We hypothesized that an accelerated "multiple rule out" CT screening of moderate-to-high risk patients will detect many clinically unrecognized diagnoses that affect change in treatment. Patients ≥ 40 years, triaged as high-risk or moderate-to-high risk according to vital signs, were eligible for inclusion. Patients were scanned with a combined ECG-gated and dual energy CT scan of cerebrum, thorax, and abdomen. The impact of the CT scan on patient diagnosis and treatment was examined prospectively by an expert panel. A total of 100 patients were included in the study, (53% female, mean age 73 years [age range, 43-93]). The scan lead to change in treatment or additional examinations in 37 (37%) patients, of which 24 (24%) were diagnostically significant, change in acute treatment in 11 (11%) cases and previously unrecognized malignant tumors in 10 (10%) cases. The mean size specific radiation dose was 15.9 mSv (± 3.1 mSv). Screening with a multi-rule out CT scan of high-risk patients in an ED is feasible and result in discovery of clinically unrecognized diagnoses and malignant tumors, but at the cost of radiation exposure and downstream examinations. The clinical impact of these findings should be evaluated in a larger randomized cohort.

  15. Association Between Concussion and Lower Extremity Injuries in Collegiate Athletes.

    PubMed

    Gilbert, Frances C; Burdette, G Trey; Joyner, A Barry; Llewellyn, Tracy A; Buckley, Thomas A

    Concussions have been associated with elevated musculoskeletal injury risk; however, the influence of unreported and unrecognized concussions has not been investigated. The purpose of this study was to examine the association between concussion and lower extremity musculoskeletal injury rates across a diverse array of sports among collegiate student-athletes at the conclusion of their athletic career. The hypothesis was that there will be a positive association between athletes who reported a history of concussions and higher rates of lower extremity injuries. Cross-sectional study. Level 3. Student-athletes (N = 335; 62.1% women; mean age, 21.2 ± 1.4 years) from 13 sports completed a reliable injury history questionnaire. Respondents indicated the total number of reported, unreported, and potentially unrecognized concussions as well as lower extremity injuries including ankle sprains, knee injuries, and muscle strains. Chi-square analyses were performed to identify the association between concussion and lower extremity injuries. There were significant associations between concussion and lateral ankle sprain ( P = 0.012), knee injury ( P = 0.002), and lower extremity muscle strain ( P = 0.031). There were also significant associations between reported concussions and knee injury ( P = 0.003), unreported concussions and knee injury ( P = 0.002), and unrecognized concussions and lateral ankle sprain ( P = 0.001) and lower extremity muscle strains ( P = 0.006), with odds ratios ranging from 1.6 to 2.9. There was a positive association between concussion history and lower extremity injuries (odds ratios, 1.6-2.9 elevated risk) among student-athletes at the conclusion of their intercollegiate athletic careers. Clinicians should be aware of these elevated risks when making return-to-participation decisions and should incorporate injury prevention protocols.

  16. Association Between Concussion and Lower Extremity Injuries in Collegiate Athletes

    PubMed Central

    Gilbert, Frances C.; Burdette, G. Trey; Joyner, A. Barry; Llewellyn, Tracy A.; Buckley, Thomas A.

    2016-01-01

    Background: Concussions have been associated with elevated musculoskeletal injury risk; however, the influence of unreported and unrecognized concussions has not been investigated. Hypothesis: The purpose of this study was to examine the association between concussion and lower extremity musculoskeletal injury rates across a diverse array of sports among collegiate student-athletes at the conclusion of their athletic career. The hypothesis was that there will be a positive association between athletes who reported a history of concussions and higher rates of lower extremity injuries. Study Design: Cross-sectional study. Level of Evidence: Level 3. Methods: Student-athletes (N = 335; 62.1% women; mean age, 21.2 ± 1.4 years) from 13 sports completed a reliable injury history questionnaire. Respondents indicated the total number of reported, unreported, and potentially unrecognized concussions as well as lower extremity injuries including ankle sprains, knee injuries, and muscle strains. Chi-square analyses were performed to identify the association between concussion and lower extremity injuries. Results: There were significant associations between concussion and lateral ankle sprain (P = 0.012), knee injury (P = 0.002), and lower extremity muscle strain (P = 0.031). There were also significant associations between reported concussions and knee injury (P = 0.003), unreported concussions and knee injury (P = 0.002), and unrecognized concussions and lateral ankle sprain (P = 0.001) and lower extremity muscle strains (P = 0.006), with odds ratios ranging from 1.6 to 2.9. Conclusion: There was a positive association between concussion history and lower extremity injuries (odds ratios, 1.6-2.9 elevated risk) among student-athletes at the conclusion of their intercollegiate athletic careers. Clinical Relevance: Clinicians should be aware of these elevated risks when making return-to-participation decisions and should incorporate injury prevention protocols. PMID:27587598

  17. Frequency of unrecognized Fabry disease among young European-American and African-American men with first ischemic stroke.

    PubMed

    Wozniak, Marcella A; Kittner, Steven J; Tuhrim, Stanley; Cole, John W; Stern, Barney; Dobbins, Mark; Grace, Marie E; Nazarenko, Irina; Dobrovolny, Robert; McDade, Eric; Desnick, Robert J

    2010-01-01

    The cause of initial ischemic stroke in up to 30% of young patients remains unclear. Fabry disease, due to deficient alpha-galactosidase A (alpha-Gal A) activity, is a vascular endothelial glycosphingolipid storage disease typically presenting in childhood. With advancing age, patients develop renal, cardiac, and cerebrovascular disease and die prematurely. A European study suggested an increased prevalence of unrecognized Fabry disease in patients with cryptogenic stroke. We hypothesized that alpha-Gal A deficiency is a rare cause of initial early-onset ischemic stroke in men. The Stroke Prevention in Young Men Study enrolled >550 men (15 to 49 years) with first ischemic stroke in the Baltimore-Washington area in 2004 to 2007. Frozen plasma samples were assayed for alpha-Gal A activity, and DNA from patients with consistently low plasma alpha-Gal A activities were sequenced. The study sample consisted of 558 men (42% African-American; median age 44 years). Stroke was cryptogenic in 154 men (40% African-American). In 10 patients with low plasma alpha-Gal A activities, DNA sequencing identified alterations in the alpha-Gal A gene in 2 patients. The polymorphism, D313Y, which results in low plasma enzyme activity, but near normal levels of cellular activity was seen in one European-American male. The Fabry disease-causing A143T mutation was seen in an African-American male with cryptogenic stroke (0.18% of all strokes: upper 95% CI=0.53%; 0.65% of cryptogenic strokes: upper 95% CI=1.92%). In this biracial population, unrecognized Fabry disease is a rare but treatable cause of initial ischemic stroke in young men.

  18. Characteristics of Black Men Who Have Sex With Men in Baltimore, Philadelphia, and Washington, D.C.: Geographic Diversity in Socio-Demographics and HIV Transmission Risk.

    PubMed

    German, Danielle; Brady, Kathleen; Kuo, Irene; Opoku, Jenevieve; Flynn, Colin; Patrick, Rudy; Park, Ju Nyeong; Adams, Joella; Carroll, Makeda; Simmons, Ron; Smith, Carlton R; Davis, Wendy W

    2017-07-01

    Baltimore, Philadelphia, and Washington, DC are geographically proximate cities with high HIV prevalence, including among black men who have sex with men (BMSM). Using data collected among BMSM in CDC's National HIV Behavioral Surveillance project, we compared socio-demographic characteristics, HIV risk behaviors, and service utilization to explore similarities and differences that could inform local and regional HIV intervention approaches. BMSM were recruited through venue time location sampling, June-December, 2011. Participants completed identical socio-behavioral surveys and voluntary HIV testing. Analyses were conducted among the full sample and those aged 18-24. Participants included 159 (DC), 364 (Baltimore), and 331 (Philadelphia) eligible BMSM. HIV prevalence was 23.1% (DC), 48.0% (Baltimore), 14.6% (Philadelphia) with 30.6%, 69.0%, 33.3% unrecognized HIV infection, respectively. Among BMSM 18-24, HIV prevalence was 11.1% (DC), 38.9% (Baltimore), 9.6% (Philadelphia) with unrecognized HIV infection 0.0%, 73.8%, 60.0% respectively. Compared with the other 2 cities, Baltimore participants were less likely to identify as gay/homosexual; more likely to report unemployment, incarceration, homelessness, sex exchange; and least likely to use the internet for partners. DC participants were more likely to have a college degree and employment. Philadelphia participants were more likely to report gay/homosexual identity, receptive condomless anal sex, having only main partners, and bars/clubs as partner meeting places. Sexually transmitted disease testing was universally low. Analyses showed especially high HIV prevalence among BMSM in Baltimore including among young BMSM. Socio-demographic characteristics and HIV infection correlates differed across cities but unrecognized HIV infection and unknown partner status were universally high.

  19. Social Class and the Extracurriculum

    ERIC Educational Resources Information Center

    Barratt, Will

    2012-01-01

    Social class is a powerful and often unrecognized influence on student participation in the extracurriculum. Spontaneous student-created extracurricular experiences depend on students affiliating and interacting with each other; student social class is a powerful influence on student affiliations. Students tend to exercise consciousness of kind-…

  20. Masculine Process/Masculine Pathology: A New Psychodynamic Approach.

    ERIC Educational Resources Information Center

    Goldberg, Herb

    1993-01-01

    Notes that traditional masculine conditioning and its underlying unconscious defenses are a major unrecognized cause of psychopathology for men today. Discusses psychodynamics of gender and manifestations of the masculine experience, and illustrates symptoms of male pathology. Hopes that this awareness provides important insights for effective…

  1. Prevalence of unrecognized dyslipidaemia in Dubai and Northern Emirates: a cross-sectional hospital based study.

    PubMed

    Vela, Barbara Karin; Alhessi, Alaaeldin Y; Popović, Marko; Al-Shaqra, Maryam A

    2008-12-01

    The aim of this study is to determine the prevalence of unrecognized dyslipidaemia and a specific correlation between lipid values and age, gender or ethnic origin in the study population. This retrospective cross-sectional study included 311 subjects who had their lipid profiles checked for the first time in a private hospital in Dubai in a six month - period. The analysis shows an increased prevalence of Low Density Lipoprotein (LDL) hypercholesterolemia with relatively higher Low Density Lipoprotein Cholesterol (LDL-c) values in male subjects (p < 0.016) as well as with the Middle East ethnic origin group (p < 0.025), while desirable High Density Lipoprotein (HDL-c) was found among female subjects (p = 0). The discordance between the percentages of elevated LDL-c and Total cholesterol (T-c) signifies the role of the LDL-c/non-HDL-c as the main surrogate for dyslipidaemia as a risk for atherosclerosis, and as a primary target of therapy.

  2. Bilateral pheochromocytoma during the postpartum period.

    PubMed

    Wattanachanya, Lalita; Bunworasate, Udomsak; Plengpanich, Wanee; Houngngam, Natnicha; Buranasupkajorn, Patinut; Sunthornyothin, Sarat; Shotelersuk, Vorasuk; Snabboon, Thiti

    2009-12-01

    Pheochromocytoma manifesting during pregnancy is uncommon but it is responsible for a high maternal and fetal mortality rate, especially when unrecognized. Most cases of pheochromocytoma are sporadic but they can be part of hereditary autosomal dominant syndromes. We describe a case of bilateral pheochromocytoma in a term-pregnant patient with a previous history of medullary thyroid carcinoma (MTC). Her genetic study revealed a heterozygous mutation, c.1900T>C, in the RET proto-oncogene which confirmed the diagnosis of multiple endocrine neoplasia type 2A (MEN2A). Unrecognized, the tumors caused a crisis with fatal outcome in the mother during the postpartum period. This event might have been prevented if the tumor had been detected previously. MEN2A affected pregnancy is an unusual condition. This syndrome should be suspected when a pregnant patient has a history of MTC. Early detection and appropriate management can prevent serious maternal and fetal complications. We also reviewed the literature of MEN2A-affected pregnancies.

  3. Parents' mental health and psychiatric expertise in child welfare family rehabilitation.

    PubMed

    Riihimäki, Kirsi

    2015-02-01

    Parents' mental health disorders are not well known within child welfare services. First, to assess the mental health disorders and treatment needs of parents participating in the child welfare-centred family rehabilitation; Second, to evaluate the work of psychiatric nurses and the effectiveness of consultations by psychiatrists in such cases. During 2010, a total of 141 parents participated in child welfare-centred family rehabilitation. The primary psychiatric disorders of parents not currently receiving psychiatric care were assessed, as was the appropriate treatment for them. The majority of parents in child welfare-centred family rehabilitation suffered from severe mental health disorders, often unrecognized and untreated. As much as 93% of parents were referred to mental health or substance abuse treatment, almost half of them to secondary care. The work of psychiatric nurses and consultations by psychiatrists were found to be useful. Most parents suffered from severe unrecognized and untreated mental health disorders. There is a high demand for adult-psychiatric expertise in child welfare.

  4. Increasing Diversity at the PhD Level in Astronomy: The Fisk-Vanderbilt Masters-to-PhD Bridge Program

    NASA Astrophysics Data System (ADS)

    Stassun, Keivan; Holley-Bockelmann, K.; Berlind, A. A.

    2013-01-01

    We briefly review the current status of underrepresented minorities in the physical sciences: The underrepresentation of Black-, Hispanic-, and Native-Americans is an order of magnitude problem. We then describe the Fisk-Vanderbilt Masters-to-PhD Bridge program as a successful model for effective partnerships with minority-serving institutions toward addressing this problem. Since 2004 the program has admitted 60 students, 54 of them underrepresented minorities (60% female), with a retention rate of 92%. The program leads the nation in master’s degrees in physics for African Americans, is one of the top ten producers of physics master’s degrees among all US citizens in general, and has become the nation’s top producer of underrepresented minority PhDs in physics, astronomy, and materials science. We summarize the main features of the program including two of its core strategies: (1) partnering a minority-serving institution and a major research university through collaborative research, and (2) using the master’s degree as a deliberate stepping stone to the PhD. We also specifically discuss one of the emerging core theories of the program: the concept of properly identifying students with 'unrealized or unrecognized potential'. We discuss our methods to recognize and select for unrealized potential during the admissions process, and how we cultivate that unrealized potential toward development of successful scientists and leaders.

  5. Posttraumatic Stress Disorder in Institutionalized World War II Veterans.

    PubMed

    Herrmann, Nathan; Eryavec, Goran

    1994-01-01

    Relatively little is known about posttraumatic stress disorder (PTSD) in World War II (WWII) veterans, despite the significant number of studies on this problem in Vietnam veterans. The authors document the prevalence of PTSD and other psychiatric disorders and investigate the etiological correlates of the syndrome in elderly, institutionalized WWII veterans. Sixty-two cognitively intact subjects (mean age 74.2 years), residents in a veterans' long-term care facility, were assessed for past and present psychopathology. A second investigator, blind to patients' psychiatric status, determined the degree of combat exposure and administered a checklist of pre-war and wartime variables. The lifetime prevalence of PTSD was 23%. Of those veterans with PTSD, 57% experienced chronic symptoms. The lifetime prevalence of other diagnoses was also high, including 3 7% for major depression and 53% for alcohol abuse. There was a strong correlation between the severity of the combat stressor and the development of PTSD. Significant correlations between PTSD and some pre-war variables were also found: more family histories of alcohol abuse, more deaths of close family members in early life, and less likelihood of having held a job for more than 1 year prior to the war. PTSD in elderly, institutionalized WWII veterans is a common, serious problem that is often unrecognized. Copyright © 1994 American Association for Geriatric Psychiatry. Published by Elsevier Inc. All rights reserved.

  6. Multi-Everything London

    ERIC Educational Resources Information Center

    Blommaert, Jan

    2008-01-01

    This commentary was written after the May Day of 2006, which hundreds of thousands of Latino immigrants in the United States used to protest against their predicament. As a largely "illegal," hence invisible and unrecognized minority, they find themselves in extremely vulnerable positions in the labour, housing, and political markets,…

  7. 36 CFR 60.14 - Changes and revisions to properties listed in the National Register.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... previously unrecognized significance in American history, architecture, archeology, engineering or culture... would be adversely affected by the intrusion of the property; and (iv) Photographs showing the proposed... adversely affected by intrusion of the property. In addition, new photographs, acreage, verbal boundary...

  8. 36 CFR 60.14 - Changes and revisions to properties listed in the National Register.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... previously unrecognized significance in American history, architecture, archeology, engineering or culture... would be adversely affected by the intrusion of the property; and (iv) Photographs showing the proposed... adversely affected by intrusion of the property. In addition, new photographs, acreage, verbal boundary...

  9. 36 CFR 60.14 - Changes and revisions to properties listed in the National Register.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... previously unrecognized significance in American history, architecture, archeology, engineering or culture... would be adversely affected by the intrusion of the property; and (iv) Photographs showing the proposed... adversely affected by intrusion of the property. In addition, new photographs, acreage, verbal boundary...

  10. 36 CFR 60.14 - Changes and revisions to properties listed in the National Register.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... previously unrecognized significance in American history, architecture, archeology, engineering or culture... would be adversely affected by the intrusion of the property; and (iv) Photographs showing the proposed... adversely affected by intrusion of the property. In addition, new photographs, acreage, verbal boundary...

  11. Childhood Depression in School Age Children.

    ERIC Educational Resources Information Center

    Willis, Sandra M.

    At any one time, between 2 percent and 17 percent of the school-age population in the United States experiences moderate to severe depression. Too often, depression goes unrecognized, damaging self-esteem, ruining academic achievement, and disrupting families. This paper discusses childhood depression and treatment. Following an introduction…

  12. TETRAVALENT LEAD: A HITHERTO UNRECOGNIZED CONTROL OF TAP WATER LEAD CONTAMINATION

    EPA Science Inventory

    Almost all of the theoretical framework underlying the control of plumbosolvency and lead release has been based on the presumption that the lead release is explicable by Pb(II) solubility, aqueous speciation, and reaction kinetics. Utilities struggling to comply with the Lead an...

  13. The economic impact of poor sample quality in clinical chemistry laboratories: results from a global survey.

    PubMed

    Erdal, Erik P; Mitra, Debanjali; Khangulov, Victor S; Church, Stephen; Plokhoy, Elizabeth

    2017-03-01

    Background Despite advances in clinical chemistry testing, poor blood sample quality continues to impact laboratory operations and the quality of results. While previous studies have identified the preanalytical causes of lower sample quality, few studies have examined the economic impact of poor sample quality on the laboratory. Specifically, the costs associated with workarounds related to fibrin and gel contaminants remain largely unexplored. Methods A quantitative survey of clinical chemistry laboratory stakeholders across 10 international regions, including countries in North America, Europe and Oceania, was conducted to examine current blood sample testing practices, sample quality issues and practices to remediate poor sample quality. Survey data were used to estimate costs incurred by laboratories to mitigate sample quality issues. Results Responses from 164 participants were included in the analysis, which was focused on three specific issues: fibrin strands, fibrin masses and gel globules. Fibrin strands were the most commonly reported issue, with an overall incidence rate of ∼3%. Further, 65% of respondents indicated that these issues contribute to analyzer probe clogging, and the majority of laboratories had visual inspection and manual remediation practices in place to address fibrin- and gel-related quality problems (55% and 70%, respectively). Probe maintenance/replacement, visual inspection and manual remediation were estimated to carry significant costs for the laboratories surveyed. Annual cost associated with lower sample quality and remediation related to fibrin and/or gel globules for an average US laboratory was estimated to be $100,247. Conclusions Measures to improve blood sample quality present an important step towards improved laboratory operations.

  14. Stability of serum, plasma and urine osmolality in different storage conditions: Relevance of temperature and centrifugation.

    PubMed

    Sureda-Vives, Macià; Morell-Garcia, Daniel; Rubio-Alaejos, Ana; Valiña, Laura; Robles, Juan; Bauça, Josep Miquel

    2017-09-01

    Osmolality reflects the concentration of all dissolved particles in a body fluid, and its measurement is routinely performed in clinical laboratories for the differential diagnosis of disorders related with the hydrolytic balance regulation, the renal function and in small-molecule poisonings. The aim of the study was to assess the stability of serum, plasma and urine osmolality through time and under different common storage conditions, including delayed centrifugation. Blood and urine samples were collected, and classified into different groups according to several preanalytical variables: serum or plasma lithium-heparin tubes; spun or unspun; stored at room temperature (RT), at 4°C or frozen at -21°C. Aliquots from each group were assayed over time, for up to 14days. Statistical differences were based on three different international performance criteria. Whole blood stability was higher in the presence of anticoagulant. Serum osmolality was stable for 2days at RT and 8days at 4°C, while plasma was less stable when refrigerated. Urine stability was 5days at RT, 4days at 4°C and >14days when frozen. Osmolality may be of great interest for the management of several conditions, such as in case of a delay in the clinical suspicion, or in case of problems in sample collection or processing. The ability to obtain reliable results for samples kept up to 14days also offers the possibility to retrospectively assess baseline values for patients which may require it. Copyright © 2017. Published by Elsevier Inc.

  15. Multi-stained whole slide image alignment in digital pathology

    NASA Astrophysics Data System (ADS)

    Déniz, Oscar; Toomey, David; Conway, Catherine; Bueno, Gloria

    2015-03-01

    In Digital Pathology, one of the most simple and yet most useful feature is the ability to view serial sections of tissue simultaneously on a computer monitor. This enables the pathologist to evaluate the histology and expression of multiple markers for a patient in a single review. However, the rate limiting step in this process is the time taken for the pathologist to open each individual image, align the sections within the viewer, with a maximum of four slides at a time, and then manually move around the section. In addition, due to tissue processing and pre-analytical steps, sections with different stains have non-linear variations between the two acquisitions, that is, they will stretch and change shape from section to section. To date, no solution has come close to a workable solution to automatically align the serial sections into one composite image. This research work address this problem to obtain an automated serial section alignment tool enabling the pathologists to simply scroll through the various sections in a single viewer. To this aim a multi-resolution intensity-based registration method using mutual information as a similarity metric, an optimizer based on an evolutionary process and a bilinear transformation has been used. To characterize the performance of the algorithm 40 cases x 5 different serial sections stained with hematoxiline-eosine (HE), estrogen receptor (ER), progesterone receptor (PR), Ki67 and human epidermal growth factor receptor 2 (Her2), have been considered. The qualitative results obtained are promising, with average computation time of 26.4s for up to 14660x5799 images running interpreted code.

  16. Antimicrobial Stewardship: How the Microbiology Laboratory Can Right the Ship

    PubMed Central

    Schwartz, David N.; Weinstein, Robert A.

    2016-01-01

    SUMMARY Antimicrobial stewardship is a bundle of integrated interventions employed to optimize the use of antimicrobials in health care settings. While infectious-disease-trained physicians, with clinical pharmacists, are considered the main leaders of antimicrobial stewardship programs, clinical microbiologists can play a key role in these programs. This review is intended to provide a comprehensive discussion of the different components of antimicrobial stewardship in which microbiology laboratories and clinical microbiologists can make significant contributions, including cumulative antimicrobial susceptibility reports, enhanced culture and susceptibility reports, guidance in the preanalytic phase, rapid diagnostic test availability, provider education, and alert and surveillance systems. In reviewing this material, we emphasize how the rapid, and especially the recent, evolution of clinical microbiology has reinforced the importance of clinical microbiologists' collaboration with antimicrobial stewardship programs. PMID:27974411

  17. Improvements in medical quality and patient safety through implementation of a case bundle management strategy in a large outpatient blood collection center.

    PubMed

    Zhao, Shuzhen; He, Lujia; Feng, Chenchen; He, Xiaoli

    2018-06-01

    Laboratory errors in blood collection center (BCC) are most common in the preanalytical phase. It is, therefore, of vital importance for administrators to take measures to improve healthcare quality and patient safety.In 2015, a case bundle management strategy was applied in a large outpatient BCC to improve its medical quality and patient safety.Unqualified blood sampling, complications, patient waiting time, largest number of patients waiting during peak hours, patient complaints, and patient satisfaction were compared over the period from 2014 to 2016.The strategy reduced unqualified blood sampling, complications, patient waiting time, largest number of patients waiting during peak hours, and patient complaints, while improving patient satisfaction.This strategy was effective in improving BCC healthcare quality and patient safety.

  18. Commercialisation of Biomarker Tests for Mental Illnesses: Advances and Obstacles.

    PubMed

    Chan, Man K; Cooper, Jason D; Bahn, Sabine

    2015-12-01

    Substantial strides have been made in the field of biomarker research for mental illnesses over the past few decades. However, no US FDA-cleared blood-based biomarker tests have been translated into routine clinical practice. Here, we review the challenges associated with commercialisation of research findings and discuss how these challenges can impede scientific impact and progress. Overall evidence indicates that a lack of research funding and poor reproducibility of findings were the most important obstacles to commercialization of biomarker tests. Fraud, pre-analytical and analytical limitations, and inappropriate statistical analysis are major contributors to poor reproducibility. Increasingly, these issues are acknowledged and actions are being taken to improve data validity, raising the hope that robust biomarker tests will become available in the foreseeable future. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Truncated cystatin C in cerebrospiral fluid: Technical [corrected] artefact or biological process?

    PubMed

    Carrette, Odile; Burkhard, Pierre R; Hughes, Severine; Hochstrasser, Denis F; Sanchez, Jean-Charles

    2005-08-01

    Cystatin C, a low molecular weight cysteine proteinase inhibitor present in human body fluids at physiological concentrations, is more expressed in cerebrospinal fluid (CSF) than in plasma. Mass spectrometric characterization showed that after 3 months of storage of human CSF at -20 degrees C, cystatin C was cleaved in the peptide bond between R8 and L9 and lost its eight N-termini amino acids, whereas this cleavage did not occur when stored at -80 degrees C. This truncation occurred in all CSF samples studied irrespective of the underlying neurological status, indicating a storage-related artefact rather than a physiological or pathological processing of the protein. These results stress the importance of optimal preanalytical storage conditions of any sample prior to proteomics studies.

  20. Synthesis of instrumentally and historically recorded earthquakes and studying their spatial statistical relationship (A case study: Dasht-e-Biaz, Eastern Iran)

    NASA Astrophysics Data System (ADS)

    Jalali, Mohammad; Ramazi, Hamidreza

    2018-06-01

    Earthquake catalogues are the main source of statistical seismology for the long term studies of earthquake occurrence. Therefore, studying the spatiotemporal problems is important to reduce the related uncertainties in statistical seismology studies. A statistical tool, time normalization method, has been determined to revise time-frequency relationship in one of the most active regions of Asia, Eastern Iran and West of Afghanistan, (a and b were calculated around 8.84 and 1.99 in the exponential scale, not logarithmic scale). Geostatistical simulation method has been further utilized to reduce the uncertainties in the spatial domain. A geostatistical simulation produces a representative, synthetic catalogue with 5361 events to reduce spatial uncertainties. The synthetic database is classified using a Geographical Information System, GIS, based on simulated magnitudes to reveal the underlying seismicity patterns. Although some regions with highly seismicity correspond to known faults, significantly, as far as seismic patterns are concerned, the new method highlights possible locations of interest that have not been previously identified. It also reveals some previously unrecognized lineation and clusters in likely future strain release.

  1. Plank fence penetration into automobiles-implications for prevention initiatives.

    PubMed

    Procter, Levi; Bernard, Andrew; Ginn, Gary; Kearney, Paul; Pienkowski, David

    2011-01-01

    The wooden plank fence presents a deadly but unrecognized hazard to motorists. We hypothesize that fence plank injury is prevalent and results in significant morbidity and mortality. Databases of the University of Kentucky's Level I Trauma Center and the Fayette County Coroner were retrospectively analyzed over a 12-year period (1995-2006). One hundred and twenty-eight subjects were involved in vehicle contact with wooden plank fences. One hundred and twenty-three subjects were evaluated at the Emergency Department of our trauma center; 35 (27%) had a patient-plank interaction (PPI). Men (30/35) were more frequently involved (86%), and average age was 32.8 years. Thirty-two (91%) were drivers; 14/35 (40%) died from PPI-related injuries. The most common cause of death was blunt head trauma in 13 of these 14 fatally injured subjects (93%). This study provides new data underscoring the frequency, lethality, and economic consequences of this injury mechanism. Further research is needed to quantify the national prevalence of this problem and develop injury-mitigating strategies pertaining to roadway or fence design. © 2010 American Academy of Forensic Sciences.

  2. Rural Australian women's legal help seeking for intimate partner violence: women intimate partner violence victim survivors' perceptions of criminal justice support services.

    PubMed

    Ragusa, Angela T

    2013-03-01

    Intimate partner violence (IPV) is a widespread, ongoing, and complex global social problem, whose victims continue to be largely women. Women often prefer to rely on friends and family for IPV help, yet when informal support is unavailable they remain hesitant to contact formal services, particularly legal support for many reasons. This study applies a sociological lens by framing the IPV and legal help-seeking experiences of rural Australian women gained from 36 in-depth face-to-face interviews as socially contextualized interactions. Findings reveal police and court responses reflect broader social inequalities and rurality exacerbates concerns such as anonymity and lack of service. Cultural differences and power imbalances between survivors and formal support providers are manifested to inform future research seeking to improve survivors' willingness to engage and satisfaction with formal services. Finally, the important role police and the criminal justice system play in de-stigmatizing IPV and legitimating its unacceptability is argued a crucial, yet unrecognized, key to social change.

  3. Exploiting position effects and the gypsy retrovirus insulator to engineer precisely expressed transgenes.

    PubMed

    Markstein, Michele; Pitsouli, Chrysoula; Villalta, Christians; Celniker, Susan E; Perrimon, Norbert

    2008-04-01

    A major obstacle to creating precisely expressed transgenes lies in the epigenetic effects of the host chromatin that surrounds them. Here we present a strategy to overcome this problem, employing a Gal4-inducible luciferase assay to systematically quantify position effects of host chromatin and the ability of insulators to counteract these effects at phiC31 integration loci randomly distributed throughout the Drosophila genome. We identify loci that can be exploited to deliver precise doses of transgene expression to specific tissues. Moreover, we uncover a previously unrecognized property of the gypsy retrovirus insulator to boost gene expression to levels severalfold greater than at most or possibly all un-insulated loci, in every tissue tested. These findings provide the first opportunity to create a battery of transgenes that can be reliably expressed at high levels in virtually any tissue by integration at a single locus, and conversely, to engineer a controlled phenotypic allelic series by exploiting several loci. The generality of our approach makes it adaptable to other model systems to identify and modify loci for optimal transgene expression.

  4. Intracranial pressure increases during exposure to a shock wave.

    PubMed

    Leonardi, Alessandra Dal Cengio; Bir, Cynthia A; Ritzel, Dave V; VandeVord, Pamela J

    2011-01-01

    Traumatic brain injuries (TBI) caused by improvised explosive devices (IEDs) affect a significant percentage of surviving soldiers wounded in Iraq and Afghanistan. The extent of a blast TBI, especially initially, is difficult to diagnose, as internal injuries are frequently unrecognized and therefore underestimated, yet problems develop over time. Therefore it is paramount to resolve the physical mechanisms by which critical stresses are inflicted on brain tissue from blast wave encounters with the head. This study recorded direct pressure within the brains of male Sprague-Dawley rats during exposure to blast. The goal was to understand pressure wave dynamics through the brain. In addition, we optimized in vivo methods to ensure accurate measurement of intracranial pressure (ICP). Our results demonstrate that proper sealing techniques lead to a significant increase in ICP values, compared to the outside overpressure generated by the blast. Further, the values seem to have a direct relation to a rat's size and age: heavier, older rats had the highest ICP readings. These findings suggest that a global flexure of the skull by the transient shockwave is an important mechanism of pressure transmission inside the brain.

  5. Adult Children of Dysfunctional Families: Treatment from a Disenfranchised Grief Perspective.

    ERIC Educational Resources Information Center

    Zupanick, Corinne E.

    1994-01-01

    Generalizes concept of disenfranchised grief to understanding of recovery process for adult children of dysfunctional families. Describes recovery process of this population as parallel to grief process. Identifies two layers of unrecognized loss: loss of one's childhood and loss of one's fantasized and idealized parent. Suggests specific…

  6. MERCURY IN METAL ORE DEPOSITS: AN UNRECOGNIZED, WIDESPREAD SOURCE TO LAKE SUPERIOR SEDIMENTS, CONTRIBUTION #1072

    EPA Science Inventory

    Mining operations have worked the rich mineral resources of the Lake Superior Basin for over 150 years, leaving industrially impacted regions with tailing piles and smelters. In Lake Superior sediments, mercury and copper inventories increase towards shorelines and are highly cor...

  7. Grief: The Unrecognized Parental Response to Mental Illness in a Child.

    ERIC Educational Resources Information Center

    MacGregor, Peggy

    1994-01-01

    Notes that parents whose son or daughter develops serious mental illness experience grief that is often neither recognized by society nor addressed by mental health professionals. Describes some common elements of parental bereavement, losses experienced with mental illness, consequences of ignoring grief, and appropriate interventions for mental…

  8. On the ecological role of salamanders

    Treesearch

    Robert D. Davic; Hartwell H. Welsh Jr.

    2004-01-01

    Salamanders are cryptic and, though largely unrecognized as such, extremely abundant vertebrates in a variety of primarily forest and grassland environments, where they regulate food webs and contribute to ecosystem resilience-resistance (= stability) in several ways: (a) As mid-level vertebrate predators, they provide direct and indirect biotic control of species...

  9. Structured Ethical Reflection in Practitioner Inquiry: Theory, Pedagogy, and Practice

    ERIC Educational Resources Information Center

    Stevens, Douglas M.; Brydon-Miller, Mary; Raider-Roth, Miriam

    2016-01-01

    Practitioner inquiry provides a powerful tool for improving practice and addressing critical issues in classrooms, schools, and broader communities. However, it also raises unique ethical challenges that often go unrecognized and unresolved. Structured Ethical Reflection (SER) provides teacher researchers with a process for identifying core values…

  10. Bipolar Disorder.

    ERIC Educational Resources Information Center

    Spearing, Melissa

    Bipolar disorder, a brain disorder that causes unusual shifts in a person's mood, affects approximately one percent of the population. It commonly occurs in late adolescence and is often unrecognized. The diagnosis of bipolar disorder is made on the basis of symptoms, course of illness, and when possible, family history. Thoughts of suicide are…

  11. 75 FR 51270 - Proposed Data Collections Submitted for Public Comment and Recommendations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-19

    ... involve conducting behavioral assessments and rapid HIV testing at a variety of events serving groups at... profiles and prevalence of unrecognized infection among individuals reachable for HIV counseling and... need for increased behavioral data among some high-risk groups that are more difficult to access or...

  12. Sexual Ethics, Organizational Climate, and the Air Expeditionary Force

    DTIC Science & Technology

    2005-04-01

    do it”. This attitude is symptomatic of the principle of emotivism . According to philosopher Alasdair MacIntyre, “What emotivism asserts is in...The unrecognized philosophical power of emotivism is one clue to its cultural power” (MacIntyre, 1984, 18). Clearly, it was not always this way

  13. Workplace Mobbing: A Discussion for Librarians

    ERIC Educational Resources Information Center

    Hecker, Thomas E.

    2007-01-01

    Workplace mobbing occurs in libraries but is usually unrecognized and unchecked because the phenomenon has not been described and given a name. This discussion provides the library profession with an overview but also with specific background details to assist with recognizing mobbing and preventing severe harm to employees and organizations.

  14. Cultural Dysthymia: An Unrecognized Disorder among African Americans?

    ERIC Educational Resources Information Center

    Vontress, Clemmont E.; Woodland, Calvin E.; Epp, Lawrence

    2007-01-01

    Many African Americans experience low-grade depression, referred to as dysthymia in the Diagnostic and Statistical Manual of Mental Disorders (4th ed., text rev.; American Psychiatric Association, 2000). After more than 250 years of enslavement, prejudice, and discrimination, dysthymia is reflected in chronic low-grade sadness, anger, hostility,…

  15. Gifted Children Grown Up.

    ERIC Educational Resources Information Center

    Freeman, Joan

    This book describes the outcomes of a longitudinal study of 210 British children that compared the recognized and the unrecognized gifted with their classmates. It describes what has happened to them and their families as they have grown up in very different circumstances, in poverty or wealth, through many types of schooling and life…

  16. The Impact of Repeated Health Checks for Adults with Intellectual Disabilities

    ERIC Educational Resources Information Center

    Felce, David; Baxter, Helen; Lowe, Kathy; Dunstan, Frank; Houston, Helen; Jones, Glyn; Felce, Janet; Kerr, Michael

    2008-01-01

    Background: An earlier study (Baxter "et al." 2006) found that a structured health check conducted in primary care identified clinically significant previously unrecognized morbidity among adults with intellectual disabilities. The aim here was to examine whether follow-up health checks would identify equally significant newly identified morbidity…

  17. Diversity at the Holarctic nexus: species of Arostrilepis (Eucestoda: Hymenolepididae) in arvicoline rodents (Cricetidae: Arvicolinae) from greater Beringia

    USDA-ARS?s Scientific Manuscript database

    Previously unrecognized species of hymenolepidid cestodes attributable to Arostrilepis Mas-Coma & Tenora, 1997 in arvicoline rodents from the greater Beringian region and western North America are described. Discovery and characterization of these tapeworms contributes to the recognition of a compl...

  18. Searching for New Double Stars with a Computer

    NASA Astrophysics Data System (ADS)

    Bryant, T. V.

    2015-04-01

    The advent of computers with large amounts of RAM memory and fast processors, as well as easy internet access to large online astronomical databases, has made computer searches based on astrometric data practicable for most researchers. This paper describes one such search that has uncovered hitherto unrecognized double stars.

  19. Level of confidence in venepuncture and knowledge in determining causes of blood sample haemolysis among clinical staff and phlebotomists.

    PubMed

    Makhumula-Nkhoma, Nellie; Whittaker, Vicki; McSherry, Robert

    2015-02-01

    To investigate the association between confidence level in venepuncture and knowledge in determining causes of blood sample haemolysis among clinical staff and phlebotomists. Various collection methods are used to perform venepuncture, also called phlebotomy, the act of drawing blood from a patient using a needle. The collection method used has an impact on preanalytical blood sample haemolysis. Haemolysis is the breakdown of red blood cells, which makes the sample unsuitable. Despite available evidence on the common causes, extensive literature search showed a lack of published evidence on the association of haemolysis with staff confidence and knowledge. A quantitative primary research design using survey method. A purposive sample of 290 clinical staff and phlebotomists conducting venepuncture in one North England hospital participated in this quantitative survey. A three-section web-based questionnaire comprising demographic profile, confidence and competence levels, and knowledge sections was used to collect data in 2012. The chi-squared test for independence was used to compare the distribution of responses for categorical data. anova was used to determine mean difference in the knowledge scores of staff with different confidence levels. Almost 25% clinical staff and phlebotomists participated in the survey. There was an increase in confidence at the last venepuncture among staff of all categories. While doctors' scores were higher compared with healthcare assistants', p ≤ 0·001, nurses' were of wide range and lowest. There was no statistically significant difference (at the 5% level) in the total knowledge scores and confidence level at the last venepuncture F(2,4·690) = 1·67, p = 0·31 among staff of all categories. Evidence-based measures are required to boost staff knowledge base of preanalytical blood sample haemolysis for standardised and quality service. Monitoring and evaluation of the training, conducting and monitoring haemolysis rate are equally crucial. Although the hospital is succeeding in providing regular training in venepuncture, this is only one aspect of quality. The process and outcome also need interventions. © 2014 John Wiley & Sons Ltd.

  20. Evaluation of the appropriate time period between sampling and analyzing for automated urinalysis

    PubMed Central

    Dolscheid-Pommerich, Ramona C.; Klarmann-Schulz, Ute; Conrad, Rupert; Stoffel-Wagner, Birgit; Zur, Berndt

    2016-01-01

    Introduction Preanalytical specifications for urinalysis must be strictly adhered to avoid false interpretations. Aim of the present study is to examine whether the preanalytical factor ‘time point of analysis’ significantly influences stability of urine samples for urine particle and dipstick analysis. Materials and methods In 321 pathological spontaneous urine samples, urine dipstick (Urisys™2400, Combur-10-Test™strips, Roche Diagnostics, Mannheim, Germany) and particle analysis (UF-1000 i™, Sysmex, Norderstedt, Germany) were performed within 90 min, 120 min and 240 min after urine collection. Results For urine particle analysis, a significant increase in conductivity (120 vs. 90 min: P < 0.001, 240 vs. 90 min: P < 0.001) and a significant decrease in WBC (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001), RBC (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001), casts (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001) and epithelial cells (120 vs. 90 min P = 0.610, 240 vs. 90 min P = 0.041) were found. There were no significant changes for bacteria. Regarding urine dipstick analysis, misclassification rates between measurements were significant for pH (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001), leukocytes (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001), nitrite (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001), protein (120 vs. 90 min P < 0.001, 240 vs. 90 min P<0.001), ketone (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001), blood (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001), specific gravity (120 vs. 90 min P < 0.001, 240 vs. 90 min P < 0.001) and urobilinogen (120 vs. 90 min, P = 0.031). Misclassification rates were not significant for glucose and bilirubin. Conclusion Most parameters critically depend on the time window between sampling and analysis. Our study stresses the importance of adherence to early time points in urinalysis (within 90 min). PMID:26981022

  1. Lost in translation: Review of identification bias, translation bias and research waste in dentistry.

    PubMed

    Layton, Danielle M; Clarke, Michael

    2016-01-01

    To review how articles are retrieved from bibliographic databases, what article identification and translation problems have affected research, and how these problems can contribute to research waste and affect clinical practice. This literature review sought and appraised articles regarding identification- and translation-bias in the medical and dental literature, which limit the ability of users to find research articles and to use these in practice. Articles can be retrieved from bibliographic databases by performing a word or index-term (for example, MeSH for MEDLINE) search. Identification of articles is challenging when it is not clear which words are most relevant, and which terms have been allocated to indexing fields. Poor reporting quality of abstracts and articles has been reported across the medical literature at large. Specifically in dentistry, research regarding time-to-event survival analyses found the allocation of MeSH terms to be inconsistent and inaccurate, important words were omitted from abstracts by authors, and the quality of reporting in the body of articles was generally poor. These shortcomings mean that articles will be difficult to identify, and difficult to understand if found. Use of specialized electronic search strategies can decrease identification bias, and use of tailored reporting guidelines can decrease translation bias. Research that cannot be found, or cannot be used results in research waste, and undermines clinical practice. Identification- and translation-bias have been shown to affect time-to-event dental articles, are likely affect other fields of research, and are largely unrecognized by authors and evidence seekers alike. By understanding that the problems exist, solutions can be sought to improve identification and translation of our research. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  2. Cancer classification in the genomic era: five contemporary problems.

    PubMed

    Song, Qingxuan; Merajver, Sofia D; Li, Jun Z

    2015-10-19

    Classification is an everyday instinct as well as a full-fledged scientific discipline. Throughout the history of medicine, disease classification is central to how we develop knowledge, make diagnosis, and assign treatment. Here, we discuss the classification of cancer and the process of categorizing cancer subtypes based on their observed clinical and biological features. Traditionally, cancer nomenclature is primarily based on organ location, e.g., "lung cancer" designates a tumor originating in lung structures. Within each organ-specific major type, finer subgroups can be defined based on patient age, cell type, histological grades, and sometimes molecular markers, e.g., hormonal receptor status in breast cancer or microsatellite instability in colorectal cancer. In the past 15+ years, high-throughput technologies have generated rich new data regarding somatic variations in DNA, RNA, protein, or epigenomic features for many cancers. These data, collected for increasingly large tumor cohorts, have provided not only new insights into the biological diversity of human cancers but also exciting opportunities to discover previously unrecognized cancer subtypes. Meanwhile, the unprecedented volume and complexity of these data pose significant challenges for biostatisticians, cancer biologists, and clinicians alike. Here, we review five related issues that represent contemporary problems in cancer taxonomy and interpretation. (1) How many cancer subtypes are there? (2) How can we evaluate the robustness of a new classification system? (3) How are classification systems affected by intratumor heterogeneity and tumor evolution? (4) How should we interpret cancer subtypes? (5) Can multiple classification systems co-exist? While related issues have existed for a long time, we will focus on those aspects that have been magnified by the recent influx of complex multi-omics data. Exploration of these problems is essential for data-driven refinement of cancer classification and the successful application of these concepts in precision medicine.

  3. Evaluation of an Innovative Tool for Child Sexual Abuse Education

    ERIC Educational Resources Information Center

    Davis, Deborah Winders; Pressley-McGruder, Gloria; Jones, V. Faye; Potter, Deborah; Rowland, Michael; Currie, Melissa; Gale, Bruce

    2013-01-01

    Child sexual abuse poses a serious threat to public health and is often unreported, unrecognized, and untreated. Prevention, early recognition, and treatment are critically important to reduce long-term effects. Little data are available on effective methods of preventing child sexual abuse. The current research demonstrates a unique approach to…

  4. Xyleborus bispinatus reared on artificial media using sawdust from avocado or silkbay in presence or absence of the laurel wilt pathogen (Raffaelea lauricola)

    USDA-ARS?s Scientific Manuscript database

    Xyleborus bispinatus Eichhoff (Coleoptera: Curculionidae: Scolytinae) was reported in Florida for the first time in 2013. Previously, it was unrecognized and not distinguished from the morphologically similar Xyleborus ferrugineus (F.). Like other members of the tribe Xyleborini, X. ferrugineus (and...

  5. Exploring Peer Interaction among Multilingual Youth: New Possibilities and Challenges for Language and Literacy Learning

    ERIC Educational Resources Information Center

    Martin-Beltrán, Melinda

    2017-01-01

    Peer interactions are central to student experiences and present tremendous opportunities for language learning and consequences for educational equity, yet these opportunities have often been unrecognized and under-examined. This special issue offers new perspectives examining the potential of peer interaction to foster language, literacy and…

  6. Edge-Region Grouping in Figure-Ground Organization and Depth Perception

    ERIC Educational Resources Information Center

    Palmer, Stephen E.; Brooks, Joseph L.

    2008-01-01

    Edge-region grouping (ERG) is proposed as a unifying and previously unrecognized class of relational information that influences figure-ground organization and perceived depth across an edge. ERG occurs when the edge between two regions is differentially grouped with one region based on classic principles of similarity grouping. The ERG hypothesis…

  7. Suppression of the Aggressive Impulse: Conceptual Difficulties in Anti-Violence Programs

    ERIC Educational Resources Information Center

    Goodman, Joan F.; Kitzmiller, Erika

    2010-01-01

    School anti-violence programs are united in their radical condemnation of aggression, generally equated with violence. The programs advocate its elimination by priming children's emotional and cognitive controls. What goes unrecognized is the embeddedness of aggression in human beings, as well as its positive psychological and moral functions. In…

  8. Neurodevelopment and Chronic Illness: Mechanisms of Disease and Treatment

    ERIC Educational Resources Information Center

    Armstrong, F. Daniel

    2006-01-01

    Successful treatment of many childhood diseases once considered terminal has resulted in the emergence of long-term effects of the disease or consequences of treatment that were previously unrecognized. Many of these long-term effects involve the central nervous system (CNS) and are developmental in the way that they emerge over time. Because we…

  9. Anxiety in Children and Adolescents with Autism Spectrum Disorders

    ERIC Educational Resources Information Center

    MacNeil, Bonnie M.; Lopes, Vicki A.; Minnes, Patricia M.

    2009-01-01

    Anxiety symptoms and disorders are highly prevalent in children and adolescents with Autism Spectrum Disorder (ASD), although they are often unrecognized or misdiagnosed. The purpose of the present review is to (1) provide clinicians with practical information on assessment and diagnosis of co-morbid anxiety in children and adolescents with ASD,…

  10. New Hepatitis E Virus Genotype in Camels, the Middle East

    PubMed Central

    Lau, Susanna K.P.; Teng, Jade L.L.; Tsang, Alan K. L.; Joseph, Marina; Wong, Emily Y.M.; Tang, Ying; Sivakumar, Saritha; Xie, Jun; Bai, Ru; Wernery, Renate; Wernery, Ulrich; Yuen, Kwok-Yung

    2014-01-01

    In a molecular epidemiology study of hepatitis E virus (HEV) in dromedaries in Dubai, United Arab Emirates, HEV was detected in fecal samples from 3 camels. Complete genome sequencing of 2 strains showed >20% overall nucleotide difference to known HEVs. Comparative genomic and phylogenetic analyses revealed a previously unrecognized HEV genotype. PMID:24856611

  11. If IDA Known: The Speaker versus the Speech in Judging Black Dialect

    ERIC Educational Resources Information Center

    Dundes, Lauren; Spence, Bill

    2007-01-01

    While students generally recognize that racism exists on an individual level, the instructor's challenge is to both elucidate patterns of discrimination and to expose their corollary: unearned and unrecognized systemic privilege of the dominant group. Unaware that their sense of entitlement advantages them at the expense of people of color, some…

  12. Suburban Schools: The Unrecognized Frontier in Public Education

    ERIC Educational Resources Information Center

    Gill, Sean; Posamentier, Jordan; Hill, Paul T.

    2016-01-01

    Over the past two decades, big cities have been the most consistent focus of investment and controversy in American public education. The challenges for big cities are obvious. Increasing numbers of foreign-born students and students living in poverty, coupled with dramatic declines in the numbers of native-born middle-class students, mean that…

  13. Student Parents, Hardship and Debt: A Qualitative Study

    ERIC Educational Resources Information Center

    Gerrard, Eve; Roberts, Ron

    2006-01-01

    To date little is known about the effects of financial hardship on student parents, who remain a significant although largely unrecognized proportion of the student population. The objective of this study was to gain an insight into their concerns and illuminate issues which may have far-reaching consequences not only for the mental and physical…

  14. The Design and Transformation of Biofundamentals: A Nonsurvey Introductory Evolutionary and Molecular Biology Course

    ERIC Educational Resources Information Center

    Klymkowsky, Michael W.; Rentsch, Jeremy D.; Begovic, Emina; Cooper, Melanie M.

    2016-01-01

    Many introductory biology courses amount to superficial surveys of disconnected topics. Often, foundational observations and the concepts derived from them and students' ability to use these ideas appropriately are overlooked, leading to unrealistic expectations and unrecognized learning obstacles. The result can be a focus on memorization at the…

  15. Missing: Children and Young People with SEBD

    ERIC Educational Resources Information Center

    Visser, John; Daniels, Harry; Macnab, Natasha

    2005-01-01

    This article explores the issue of missing from and missing out on education. It argues that too little is known with regard to the characteristics of children and young people missing from schooling. It postulates that many of these pupils will have social, emotional and behavioural difficulties which are largely unrecognized and thus not…

  16. Fatal Metacestode Infection in Bornean Orangutan Caused by Unknown Versteria Species

    PubMed Central

    Gendron-Fitzpatrick, Annette; Deering, Kathleen M.; Wallace, Roberta S.; Clyde, Victoria L.; Lauck, Michael; Rosen, Gail E.; Bennett, Andrew J.; Greiner, Ellis C.; O’Connor, David H.

    2014-01-01

    A captive juvenile Bornean orangutan (Pongo pygmaeus) died from an unknown disseminated parasitic infection. Deep sequencing of DNA from infected tissues, followed by gene-specific PCR and sequencing, revealed a divergent species within the newly proposed genus Versteria (Cestoda: Taeniidae). Versteria may represent a previously unrecognized risk to primate health. PMID:24377497

  17. The Impact of Depression on Mothers and Children

    ERIC Educational Resources Information Center

    Beardslee, William R.; Gladstone, Tracy R. G.; Diehl, Anne

    2014-01-01

    Depression in pregnant women and mothers of very young children is a pressing public health issue. Maternal depression is linked to a number of serious difficulties for mothers, their young children, and mother-child relationships. Unrecognized and untreated, it can lead to long-lasting impairment for both mothers and their children. However,…

  18. SITUATION OF THE SPANISH AMERICANS OF NORTHERN NEW MEXICO.

    ERIC Educational Resources Information Center

    KNOWLTON, CLARK S.

    THE SPANISH AMERICANS OF NORTHERN NEW MEXICO HAVE CONSTITUTED ONE OF THE UNRECOGNIZED DISADVANTAGED GROUPS. PER CAPITA INCOME IS LOW AND THE RATES OF UNEMPLOYMENT AND WELFARE ARE HIGH. THE CAUSES OF THE PRESENT SITUATION ARE--(1) LOSS OF LAND, (2) CULTURAL AND LINGUISTIC DISCRIMINATORY ATTITUDES, (3) NON-PROVISION OF ADEQUATE PROGRAMS TO…

  19. 26 CFR 1.860A-0 - Outline of REMIC provisions.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... persons. § 1.860C-2Determination of REMIC taxable income or net loss. (a) Treatment of gain or loss. (b... documents. (b) Treatment of sponsor. (1) Sponsor defined. (2) Nonrecognition of gain or loss. (3) Basis of... expense defined. (B) Syndication expenses. (iii) Pricing date. (4) Treatment of unrecognized gain or loss...

  20. Quality Issues in Propulsion

    NASA Technical Reports Server (NTRS)

    McCarty, John P.; Lyles, Garry M.

    1997-01-01

    Propulsion system quality is defined in this paper as having high reliability, that is, quality is a high probability of within-tolerance performance or operation. Since failures are out-of-tolerance performance, the probability of failures and their occurrence is the difference between high and low quality systems. Failures can be described at 3 levels: the system failure (which is the detectable end of a failure), the failure mode (which is the failure process), and the failure cause (which is the start). Failure causes can be evaluated & classified by type. The results of typing flight history failures shows that most failures are in unrecognized modes and result from human error or noise, i.e. failures are when engineers learn how things really work. Although the study based on US launch vehicles, a sampling of failures from other countries indicates the finding has broad application. The parameters of the design of a propulsion system are not single valued, but have dispersions associated with the manufacturing of parts. Many tests are needed to find failures, if the dispersions are large relative to tolerances, which could contribute to the large number of failures in unrecognized modes.

  1. Previously Unrecognized Large Lunar Impact Basins Revealed by Topographic Data

    NASA Technical Reports Server (NTRS)

    Frey, Herbert V.

    2008-01-01

    The discovery of a large population of apparently buried impact craters on Mars, revealed as Quasi- Circular Depressions (QCDs) in Mars Orbiting Laser Altimeter (MOLA) data [1,2,3] and as Circular Thin Areas (CTAs) [4] in crustal thickness model data [5] leads to the obvious question: are there unrecognized impact features on the Moon and other bodies in the solar system? Early analysis of Clementine topography revealed several large impact basins not previously known [6,7], so the answer certainly is "Yes." How large a population of previously undetected impact basins, their size frequency distribution, and how much these added craters and basins will change ideas about the early cratering history and Late Heavy Bombardment on the Moon remains to be determined. Lunar Orbiter Laser Altimeter (LOLA) data [8] will be able to address these issues. As a prelude, we searched the state-of-the-art global topographic grid for the Moon, the Unified Lunar Control Net (ULCN) [9] for evidence of large impact features not previously recognized by photogeologic mapping, as summarized by Wilhelms [lo].

  2. Unsuspected Leptospirosis Is a Cause of Acute Febrile Illness in Nicaragua

    PubMed Central

    Reller, Megan E.; Wunder, Elsio A.; Miles, Jeremy J.; Flom, Judith E.; Mayorga, Orlando; Woods, Christopher W.; Ko, Albert I.; Dumler, J. Stephen; Matute, Armando J.

    2014-01-01

    Background Epidemic severe leptospirosis was recognized in Nicaragua in 1995, but unrecognized epidemic and endemic disease remains unstudied. Methodology/Principal Findings To determine the burden of and risk factors associated with symptomatic leptospirosis in Nicaragua, we prospectively studied patients presenting with fever at a large teaching hospital. Epidemiologic and clinical features were systematically recorded, and paired sera tested by IgM-ELISA to identify patients with probable and possible acute leptospirosis. Microscopic Agglutination Test and PCR were used to confirm acute leptospirosis. Among 704 patients with paired sera tested by MAT, 44 had acute leptospirosis. Patients with acute leptospirosis were more likely to present during rainy months and to report rural residence and fresh water exposure. The sensitivity of clinical impression and acute-phase IgM detected by ELISA were poor. Conclusions/Significance Leptospirosis is a common (6.3%) but unrecognized cause of acute febrile illness in Nicaragua. Rapid point-of-care tests to support early diagnosis and treatment as well as tests to support population-based studies to delineate the epidemiology, incidence, and clinical spectrum of leptospirosis, both ideally pathogen-based, are needed. PMID:25058149

  3. Science beyond boundary: are premature discoveries things of the past?

    PubMed

    Singh, Rama S

    2016-06-01

    Mendel's name more than of any other draws our attention to the personal side in terms of success and failure in science. Mendel lived 19 years after presenting his research findings and died without receiving any recognition for his work. Are premature discoveries things of the past, you may ask? I review the material basis of science in terms of science boundary and field accessibility and analyze the possibility of premature discoveries in different fields of science such as, for example, physics and biology. I conclude that science has reached a stage where progress is being made mostly by pushing the boundary of the known from inside than by leaping across boundaries. As more researchers become engaged in science, and as more publications become open access, on-line, and interactive, the probability of an important discovery remaining buried and going unrecognized would become exceedingly small. Of course, as examples from physics show, a new theory or an important idea can always lie low, unrecognized until it becomes re-discovered and popularized by other researchers. Thus, premature discoveries will become less likely but not forbidden.

  4. Unrecognized astrometric confusion in the Galactic Centre

    NASA Astrophysics Data System (ADS)

    Plewa, P. M.; Sari, R.

    2018-06-01

    The Galactic Centre is a crowded stellar field and frequent unrecognized events of source confusion, which involve undetected faint stars, are expected to introduce astrometric noise on a sub-mas level. This confusion noise is the main non-instrumental effect limiting the astrometric accuracy and precision of current near-infrared imaging observations and the long-term monitoring of individual stellar orbits in the vicinity of the central supermassive black hole. We self-consistently simulate the motions of the known and the yet unidentified stars to characterize this noise component and show that a likely consequence of source confusion is a bias in estimates of the stellar orbital elements, as well as the inferred mass and distance of the black hole, in particular if stars are being observed at small projected separations from it, such as the star S2 during pericentre passage. Furthermore, we investigate modelling the effect of source confusion as an additional noise component that is time-correlated, demonstrating a need for improved noise models to obtain trustworthy estimates of the parameters of interest (and their uncertainties) in future astrometric studies.

  5. Community-acquired adult Escherichia coli meningitis leading to diagnosis of unrecognized retropharyngeal abscess and cervical spondylodiscitis: a case report.

    PubMed

    Kohlmann, Rebekka; Nefedev, Andrey; Kaase, Martin; Gatermann, Sören G

    2015-12-12

    Escherichia coli is a rare cause of community-acquired meningitis in adults unless predisposing factors are present (e.g., previous penetrating cranio-cerebral injury or neurosurgery, immunosuppression, chronic alcoholism, history of cancer, diabetes mellitus, advanced age). We describe the case of a 53-year-old woman, resident in Germany, suffering from community-acquired bacterial meningitis caused by CTX-M-9 type extended spectrum β-lactamase producing Escherichia coli. Because typical predisposing factors were not apparent, pathogen identification resulted in expanded diagnostics to exclude a distant or contiguous primary focus. By magnetic resonance tomography, a previously unrecognized large retropharyngeal abscess with cervical spondylodiscitis was detected. In retrospect, the patient had complained about neck pain for a few weeks prior to meningitis onset, but the symptoms were interpreted as being related to a herniated disk. Meningitis and osteomyelitis resolved completely under surgical treatment and meropenem therapy. In case of adult Escherichia coli meningitis, underlying diseases should always be carefully excluded, especially if predisposing factors are not apparent.

  6. Computers and clinical arrhythmias.

    PubMed

    Knoebel, S B; Lovelace, D E

    1983-02-01

    Cardiac arrhythmias are ubiquitous in normal and abnormal hearts. These disorders may be life-threatening or benign, symptomatic or unrecognized. Arrhythmias may be the precursor of sudden death, a cause or effect of cardiac failure, a clinical reflection of acute or chronic disorders, or a manifestation of extracardiac conditions. Progress is being made toward unraveling the diagnostic and therapeutic problems involved in arrhythmogenesis. Many of the advances would not be possible, however, without the availability of computer technology. To preserve the proper balance and purposeful progression of computer usage, engineers and physicians have been exhorted not to work independently in this field. Both should learn some of the other's trade. The two disciplines need to come together to solve important problems with computers in cardiology. The intent of this article was to acquaint the practicing cardiologist with some of the extant and envisioned computer applications and some of the problems with both. We conclude that computer-based database management systems are necessary for sorting out the clinical factors of relevance for arrhythmogenesis, but computer database management systems are beset with problems that will require sophisticated solutions. The technology for detecting arrhythmias on routine electrocardiograms is quite good but human over-reading is still required, and the rationale for computer application in this setting is questionable. Systems for qualitative, continuous monitoring and review of extended time ECG recordings are adequate with proper noise rejection algorithms and editing capabilities. The systems are limited presently for clinical application to the recognition of ectopic rhythms and significant pauses. Attention should now be turned to the clinical goals for detection and quantification of arrhythmias. We should be asking the following questions: How quantitative do systems need to be? Are computers required for the detection of all arrhythmias? In all settings? Should we be focusing alternatively on those arrhythmias that are frequent and with clinical significance? The ultimate test of any technology is, after all, its use in advancing knowledge and patient care.

  7. Psychiatric Consultation and Substance Use Disorders

    PubMed Central

    Specker, Sheila; Meller, William H.; Thurber, Steven

    2009-01-01

    Background A substantial number of patients in general hospitals will evince substance abuse problems but a majority is unlikely to be adequately identified in the referral-consultation process. This failure may preclude patients from receiving effective interventions for substance use disorders. Objectives 1. To evaluate all referred patients for possible substance use disorders. 2. To ascertain the degree of convergence between patients referred for chemical problems and the corresponding DSM diagnosis. 3. To compare demographic data for substance abusing patients and referrals not so classified. 4. To evaluate conditions concomitant with substance use disorders. Method Consecutive one-year referrals (524) to consultation-liaison psychiatric services were scrutinized for chemically-related problems by psychiatric consultants. Results Of the referrals, 176 met criteria for substance use disorders (SUD) (57% alcohol; 25% other drugs; 18% both alcohol and other drugs). Persons diagnosed with SUD tended to be younger, male, non-Caucasian, unmarried, and unemployed. They were more likely to be depressed, have liver and other gastrointestinal problems, and to have experienced traumatic events; they also tended to have current financial difficulties. Most were referred for SUD evaluation by personnel in general medicine and family practice. Following psychiatric consultation, SUD designated patients were referred mainly to substance abuse treatment programs. The only variable related to recommended inpatient versus outpatient services for individuals with SUD was the Global Assessment of Functioning Axis (GAF) with persons having lower estimated functioning more likely to be referred for inpatient interventions. Conclusions These data are similar to the results of past studies in this area. Unlike previous investigations in the domain of consultative-liaison psychiatry, financial stressors and specific consultant recommendations were included in data gathering. Although the results are encouraging in that individuals with SUD were identified and potentially sent for appropriate treatment, the likelihood is that many patients with SUD remain unrecognized and do not receive necessary consultative and treatment services. PMID:24357934

  8. Psychiatric consultation and substance use disorders.

    PubMed

    Specker, Sheila; Meller, William H; Thurber, Steven

    2009-01-01

    A substantial number of patients in general hospitals will evince substance abuse problems but a majority is unlikely to be adequately identified in the referral-consultation process. This failure may preclude patients from receiving effective interventions for substance use disorders. 1. To evaluate all referred patients for possible substance use disorders. 2. To ascertain the degree of convergence between patients referred for chemical problems and the corresponding DSM diagnosis. 3. To compare demographic data for substance abusing patients and referrals not so classified. 4. To evaluate conditions concomitant with substance use disorders. Consecutive one-year referrals (524) to consultation-liaison psychiatric services were scrutinized for chemically-related problems by psychiatric consultants. Of the referrals, 176 met criteria for substance use disorders (SUD) (57% alcohol; 25% other drugs; 18% both alcohol and other drugs). Persons diagnosed with SUD tended to be younger, male, non-Caucasian, unmarried, and unemployed. They were more likely to be depressed, have liver and other gastrointestinal problems, and to have experienced traumatic events; they also tended to have current financial difficulties. Most were referred for SUD evaluation by personnel in general medicine and family practice. Following psychiatric consultation, SUD designated patients were referred mainly to substance abuse treatment programs. The only variable related to recommended inpatient versus outpatient services for individuals with SUD was the Global Assessment of Functioning Axis (GAF) with persons having lower estimated functioning more likely to be referred for inpatient interventions. These data are similar to the results of past studies in this area. Unlike previous investigations in the domain of consultative-liaison psychiatry, financial stressors and specific consultant recommendations were included in data gathering. Although the results are encouraging in that individuals with SUD were identified and potentially sent for appropriate treatment, the likelihood is that many patients with SUD remain unrecognized and do not receive necessary consultative and treatment services.

  9. Preschoolers’ Emotion Knowledge and the Differential Effects of Harsh Punishment

    PubMed Central

    Berzenski, Sara R.; Yates, Tuppett M.

    2013-01-01

    This study examined the influence of caregiver-reported harsh physical and verbal punishment on children’s behavioral and self-system adjustment. Children’s emotion knowledge was evaluated as a heretofore unrecognized moderator of these relations. Two hundred fifty preschool age children (50% female; Mage=49.06 months) from diverse backgrounds (50% Hispanic, 18% African American, 10.4% Caucasian, 21.6% Multiracial/Other) were assessed through teacher, caregiver, self, and observer report in the domains of harsh punishment (Parent Child Conflict Tactics Scale), conduct problems (Teacher Report Form, California Child Q-Sort), self concept (Self Description Questionnaire for Preschoolers, California Child Q-Sort), and emotion knowledge (Kuschè Emotion Inventory). Emotion knowledge moderated the relation between harsh punishment and child adjustment. Harsh physical punishment was associated with conduct problems for children with higher emotion knowledge, especially for boys. Harsh verbal punishment was associated with self concept deficits among children with higher emotion knowledge, especially for girls. These relations were also specifically applicable to non-Hispanic children. These results highlight the importance of investigating hypothesis driven interactive effects and the specificity of experience to understand the psychosocial sequelae of parenting practices broadly, and to clarify the mixed evidence in the punishment literature specifically. Clinical implications point to the salience of emotion processes in parent-child disciplinary interventions for understanding the prevalence and pattern of child behavioral adjustment and self concept, as well as more broadly to the role of individual differences in children’s responses to adversity and subsequent therapeutic needs. PMID:23750528

  10. [Hyperkalemia - what the general practitioner must know].

    PubMed

    Schnyder, Aurelia; Hüsler, Carina; Binet, Isabelle

    2015-03-25

    Hyperkalemia can be a challenge for the general practitioner as it can prove to be benign as well as life-threatening. From a diagnostic point of view, four possibilities have to be differenciated: a pre-analytical cause, potassium release through cell lysis, a potassium shift, a reduced renal excretion of potassium. The first differential diagnosis can often be carried out by a thorough medical history, in particular the medication intake. Also, the first clinical and laboratory investigations can take place at the general practitioner's clinic. If the hyperkalemia proves to be a true hyperkalemia or cannot be explained by poly-medication and known diseases of the patient, not yet identified renal, endocrine or cardiac diseases should be searched for. If a serious condition is identified as the cause of hyperkalemia the patient should be referred to a specialized clinic.

  11. Antimicrobial Stewardship: How the Microbiology Laboratory Can Right the Ship.

    PubMed

    Morency-Potvin, Philippe; Schwartz, David N; Weinstein, Robert A

    2017-01-01

    Antimicrobial stewardship is a bundle of integrated interventions employed to optimize the use of antimicrobials in health care settings. While infectious-disease-trained physicians, with clinical pharmacists, are considered the main leaders of antimicrobial stewardship programs, clinical microbiologists can play a key role in these programs. This review is intended to provide a comprehensive discussion of the different components of antimicrobial stewardship in which microbiology laboratories and clinical microbiologists can make significant contributions, including cumulative antimicrobial susceptibility reports, enhanced culture and susceptibility reports, guidance in the preanalytic phase, rapid diagnostic test availability, provider education, and alert and surveillance systems. In reviewing this material, we emphasize how the rapid, and especially the recent, evolution of clinical microbiology has reinforced the importance of clinical microbiologists' collaboration with antimicrobial stewardship programs. Copyright © 2016 American Society for Microbiology.

  12. [ABOUT UNIFICATION OF LABORATORY CRITERIA OF DIFFERENTIATION OF BACTERIAL VAGINOSIS].

    PubMed

    Mavzutov, A R; Tsvetkova, A V; Muretdinova, L A

    2015-06-01

    The article presents analysis of laboratory criteria and classifcations used to interpret results of laboratory analysis by technique of microscopy on bacterial vaginosis or dysbacteriosis of vagina. Their advantages and restrictions are demonstrated The unified criteria of evaluation are proposed concerning results of microscopy of mucosal discharge of vagina and corresponding classification. Thereafter, three degrees of bacterial vaginosis (dysbacteriosis of vagina) are differentiated: first degree--compensated dysbacteriosis of vagina, second degree--sub compensated dysbacteriosis of vagina and third degree--decompensated dysbacteriosis of vagina. The corresponding laboratory report of physician is formulated. The proposals are presented concerning development of common unified requirements to stages (pre-analytical, analytical, post-analytical) of laboratory diagnostic of bacterial vaginosis (dysbacteriosis of vagina) with purpose of their unambiguous understanding by clinicians and hence their decision making concerning necessity and tactics of management of patient.

  13. Hepatitis E virus as an etiology of acute exacerbation of previously unrecognized asymptomatic patients with hepatitis B virus-related chronic liver disease.

    PubMed

    Kumar, Manoj; Sharma, Barjesh C; Sarin, Shiv K

    2008-06-01

    Hepatitis E virus (HEV) has recently been implicated in episodes of acute decompensation in patients having underlying chronic liver disease (CLD) of varying etiology. However, HEV as a cause of acute exacerbation of previously asymptomatic and unrecognized hepatitis B virus (HBV)-infected patients is less well described. The aim of the present study was to investigate the etiology of acute exacerbation of previously asymptomatic and unrecognized HBV-infected patients and to evaluate the relative role of HEV. We also investigated the effect of superinfection on the clinical spectrum of underlying HBV infection. Forty-three patients presented with the following were retrospectively analyzed: (i) clinical features suggestive of acute hepatitis; (ii) with hepatitis B surface antigen (HBsAg) (+); (iii) IgM hepatitis B core antibody (IgM anti-HBc) (-); (iv) no previous history of liver disease; (v) no features suggestive of CLD at presentation; (vi) HBsAg remaining (+) for at least 12 months on follow up; and (vii) having a follow-up biopsy during the convalescent phase showing evidence of chronic hepatitis B. Of the 43 patients, 21 were hepatitis e antigen (HBeAg) (+) (Gr.1) and 22 HBeAg (-) (Gr.2) at presentation. In Gr.1, only two (9.5%) had superinfection (both with hepatitis A virus), whereas in Gr.2, 11 (50%) had superinfection (27.3% hepatitis E, 13.6% hepatitis A and 9.1% both) (P = 0.007). In Gr.1, the remaining 19 (90.5%) patients had spontaneous exacerbation (immune clearance with spontaneous seroconversion) whereas in Gr.2, the remaining 11 (50%) had spontaneous exacerbation (due to reactivation). Overall, HEV superinfection contributed to 20% of acute exacerbation episodes and, in particular, 36% of episodes in initially HBeAg (-) patients. Time to alanine aminotransferase normalization was longer in patients with superinfection (n = 13) as compared to spontaneous exacerbation (n = 30) (median [range] 36 [8-48]vs 16 [6-36] weeks, P = 0.001). During convalescence, there was no significant difference between histological activity index score (median [range] 8 [4-11]vs 8 [4-16] weeks, P = 0.629) and fibrosis scores (median [range] 3.5 [1-4]vs 2 [1-4] weeks, P = 0.099] on liver biopsy after recovery among patients with acute exacerbation due to superinfection and spontaneous exacerbation. Acute exacerbations in HBeAg (+) patients are most often due to spontaneous viral activation, while in HBeAg (-) patients, superinfection with non-B hepatitis viruses and spontaneous viral activation are equally common. HEV is an important cause of acute exacerbation in previously asymptomatic and unrecognized patients with HBV-related CLD.

  14. Xyleborus bispinatus (Coleoptera: Curculionidae) reared on artificial media using sawdust from avocado or silkbay in presence or absence of the laurel wilt pathogen (Raffaelea lauricola).

    USDA-ARS?s Scientific Manuscript database

    Xyleborus bispinatus Eichhoff (Coleoptera: Curculionidae) was reported in Florida for the first time in 2013. Previously, it was unrecognized and not distinguished from the morphologically similar Xyleborus ferrugineus (F.). Like other members of the tribe Xyleborini, X. ferrugineus (and possibly X....

  15. Consistent negative temperature sensitivity and positive influence of precipitation on growth of floodplain Picea glauca in Interior Alaska

    Treesearch

    Glenn Patrick Juday; Claire. Alix

    2012-01-01

    This paper calibrates climate controls over radial growth of floodplain white spruce (Picea glauca (Moench) Voss) and examines whether growth in these populations responds similarly to climate as upland trees in Interior Alaska. Floodplain white spruce trees hold previously unrecognized potential for long-term climate reconstruction because they...

  16. Peer-Reviewed Exploration in Teaching: A Program for Stimulating and Recognizing Innovations in Teaching

    ERIC Educational Resources Information Center

    Simha, Rahul; Teodorescu, Raluca

    2017-01-01

    In an academic world driven by student ratings and publication counts, faculty members are discouraged from exploring new pedagogical ideas because exploration takes time and often goes unrecognized. The contrast with research is striking: everyone is expected to explore and innovate in research, whereas very few make exploration in teaching their…

  17. Growing hickories (Carya spp.) for roost trees: A method to support conservation of declining bat populations

    Treesearch

    Tara Luna; Daniel L. Lindner; R. Kasten Dumroese

    2014-01-01

    Bats (Vespertilionidae and Phyllostomidae) are a critically important component of North American ecosystems. These insectivorous mammals provide largely unrecognized ecosystem services to agriculture and forest health and sustain bat-dependent native plant populations. The decline of North American bat populations reflects the recent emergence of the fungal disease...

  18. Enhancing Self-Determination in Health: Results of an RCT of the Ask Project, a School-Based Intervention for Adolescents with Intellectual Disability

    ERIC Educational Resources Information Center

    McPherson, Lyn; Ware, Robert S.; Carrington, Suzanne; Lennox, Nicholas

    2017-01-01

    Background: Adolescents with intellectual disability have high levels of unrecognized disease and inadequate health screening/promotion which might be addressed by improving health advocacy skills. Methods: A parallel-group cluster randomized controlled trial was conducted to investigate whether a health intervention package, consisting of…

  19. Bereaved Adults with Intellectual Disabilities: A Combined Randomized Controlled Trial and Qualitative Study of Two Community-Based Interventions

    ERIC Educational Resources Information Center

    Dowling, S.; Hubert, J.; White, S.; Hollins, S.

    2006-01-01

    Background: Bereaved adults with intellectual disabilities are known to experience prolonged and atypical grief which is often unrecognized. The aim of this project was to find an effective way to improve mental health and behavioural outcomes. Methods: Subjects were randomized to two different therapeutic interventions: traditional counselling by…

  20. Air travel and venous thromboembolism: minimizing the risk.

    PubMed

    Bartholomew, John R; Schaffer, Jonathan L; McCormick, Georges F

    2011-02-01

    For those traveling on long flights, the risk of deep vein thrombosis or pulmonary embolism, generally referred to as venous thromboembolism (VTE), is real and dangerous if left unrecognized or untreated. The goal of this publication is to provide an overview of how best to prevent VTE during travel, and how to diagnose and treat it.

  1. Identifying Threshold Concepts for Information Literacy: A Delphi Study

    ERIC Educational Resources Information Center

    Townsend, Lori; Hofer, Amy R.; Hanick, Silvia Lin; Brunetti, Korey

    2016-01-01

    This study used the Delphi method to engage expert practitioners on the topic of threshold concepts--core ideas and processes in a discipline that students need to grasp in order to progress in their learning, but that are often unspoken or unrecognized by expert practitioners--for information literacy. A panel of experts considered two questions:…

  2. Developing Cross-Cultural Awareness in IT: Reflections of Australian and Chinese Students

    ERIC Educational Resources Information Center

    Venables, Anne; Tan, Grace; Miliszewska, Iwona

    2013-01-01

    To succeed within the increasingly global context of their work environment, today's IT professional needs to be equipped with both cutting-edge technical skills and a strong repertoire of "soft" skills. An important and often unrecognized soft skill is an appreciation of how various IT issues impact upon different peoples and what…

  3. Using a Critical Reflection Framework and Collaborative Inquiry to Improve Teaching Practice: An Action Research Project

    ERIC Educational Resources Information Center

    Briscoe, Patricia

    2017-01-01

    This action research reports on a three-year collaborative learning process among three teachers. We used current literature and a critical reflection framework to understand why our teaching approaches were not resulting in increased student learning. This allowed us to examine our previously unrecognized and uninterrupted--and often,…

  4. Commentary on Reviews of James Tooley's "The Beautiful Tree" and Tooley's Reply

    ERIC Educational Resources Information Center

    Yagnamurthy, Sreekanth; Tooley, James

    2011-01-01

    In this commentary Yagnamurthy raises several issues such as right to education, English as the medium of instruction, and quality of education in low-fee and unrecognized schools. Also, Yagnamurthy is of the view that both public and private sectors need to endeavor for equitable participation of all children in education. Tooley replies.

  5. Abnormally low hCG in a complete hydatidiform molar pregnancy: The hook effect.

    PubMed

    Nodler, James L; Kim, Kenneth H; Alvarez, Ronald D

    2011-01-01

    ► The hook effect occurs with extremely high levels of hCG, saturating detection antibodies, leading to falsely low laboratory results. ► In the literature, descriptions of the hook effect are rare in cases of gestational trophoblastic diseases. ► If unrecognized, this can lead to delayed therapy or mismanagement of care.

  6. Development of the Little Developmental Coordination Disorder Questionnaire for Preschoolers and Preliminary Evidence of Its Psychometric Properties in Israel

    ERIC Educational Resources Information Center

    Rihtman, Tanya; Wilson, Brenda N.; Parush, Shula

    2011-01-01

    Purpose: The early identification of motor coordination challenges before school age may enable close monitoring of a child's development and perhaps ameliorate some of the social, psychological and behavioral sequela that often accompany unrecognized Developmental Coordination Disorder (DCD). The purpose of this study was to develop and assess…

  7. Unrecognized Dengue Virus Infections in Children, Western Kenya, 2014-2015.

    PubMed

    Vu, David M; Mutai, Noah; Heath, Claire J; Vulule, John M; Mutuku, Francis M; Ndenga, Bryson A; LaBeaud, A Desiree

    2017-11-01

    We detected a cluster of dengue virus infections in children in Kenya during July 2014-June 2015. Most cases were serotype 1, but we detected all 4 serotypes, including co-infections with 2 serotypes. Our findings implicate dengue as a cause of febrile illness in this population and highlight a need for robust arbovirus surveillance.

  8. The Success and Struggles of Filipino Geriatric Nurses in Nursing Homes

    ERIC Educational Resources Information Center

    de Guzman, Allan B.; Coronel, Rona Denise V.; Chua, Kannerin O.; Constantino, Mariz G.; Cordova, Ericsann James C.

    2009-01-01

    Geriatric nursing is a physically and emotionally demanding job in healthcare. It is a neglected field despite the growing population of the elderly, and the experiences of geriatric nurses are one of the unrecognized aspects of this field. This qualitative study purports to explore the successes and struggles of the lived experiences of a select…

  9. Language Management: A Snapshot of Governmentality within the Private Schools in Quetta, Pakistan

    ERIC Educational Resources Information Center

    Manan, Syed Abdul; David, Maya Khemlani; Dumanig, Francisco Perlas

    2016-01-01

    Pakistan is a multilingual and multiethnic country; however, this diversity stands unrecognized in the formal language-in-education policies. Estimates suggest that about 90% of children who speak over 60 indigenous languages do not have access to education in their mother tongues. Linguists estimate that exclusive teaching of Urdu and English…

  10. Unrecognized Cultural Conventions for Assessing Word Reading That Affect Research and Practice

    ERIC Educational Resources Information Center

    Fletcher-Flinn, Claire M.; Thompson, G. Brian; Yamada, Megumi; Naka, Makiko

    2014-01-01

    In research on the acquisition of reading, there have been cross-orthographic comparisons made between some alphabetic scripts and a few syllabic scripts. In the present study of Japanese Grade 1 children learning to read hiragana, a syllabic script, there was a comparison of assessments of oral word reading accuracy levels recorded by scorers…

  11. Assessment of ecosystem services provided by urban trees: public lands within the Urban Growth Boundary of Corvallis, OR

    EPA Science Inventory

    Public lands within the Urban Growth Boundary of Corvallis, Oregon contain a diverse population of about 440,000 trees that include over 300 varieties and have an estimated tree cover of 31%. While often unrecognized, urban trees provide a variety of “ecosystem services” or dire...

  12. Beyond Black and White. New Faces and Voices in U.S. Schools. SUNY Series, Power, Social Identity, and Education.

    ERIC Educational Resources Information Center

    Seller, Maxine, Ed.; Weis, Lois, Ed.

    This collection explores diversity in American schools by opening the discussion to the unprecedented diversity of children in American schools. Sections on rethinking familiar minorities, newcomers to the country, and other, often unrecognized minorities, deal with the common themes of minority status, marginality, and resistance. The following…

  13. Community Health Workers in Health-Related Missouri Agencies: Role, Professional Development and Health Information Needs

    ERIC Educational Resources Information Center

    Visker, Joseph; Rhodes, Darson; Cox, Carol

    2017-01-01

    Community Health Workers (CHWs) serve an indispensable but oftten misunderstood and unrecognized role in public health. These individuals constitute the frontline of health care in many communities and are relied upon to provide an assortment of services. Unfortunately, the full extent to which CHWs are utilized is unknown and there is little…

  14. Hymenolepis folkertsi n. sp. (Eucestoda: Hymenolepididae) in the oldfield mouse Peromyscus polionotus from the southeastern Nearctic with comments on tapeworm faunal diversity among deer mice

    USDA-ARS?s Scientific Manuscript database

    A previously unrecognized species of hymenolepidid cestode attributable to Hymenolepis Weinland, 1858 is described based on specimens in Peromyscus polionotus, oldfield mouse, from Georgia near the southeastern coast of continental North America. Specimens of Hymenolepis folkertsi n. sp. differ from...

  15. Elder Abuse and Neglect: Considerations for Mental Health Practitioners

    ERIC Educational Resources Information Center

    Thompson, Heather; Priest, Ronnie

    2005-01-01

    Elder abuse and neglect are prevalent throughout the U.S. and are often unrecognized and untreated. It is projected that by the year 2030, the number of older adults (age 60 and older) will double, thereby increasing the likelihood that mental health practitioners will encounter instances of elder abuse and neglect. The authors address the…

  16. Beyond Grand Rounds: A Comprehensive and Sequential Intervention to Improve Identification of Delirium

    ERIC Educational Resources Information Center

    Ramaswamy, Ravishankar; Dix, Edward F.; Drew, Janet E.; Diamond, James J.; Inouye, Sharon K.; Roehl, Barbara J. O.

    2011-01-01

    Purpose of the Study: Delirium is a widespread concern for hospitalized seniors, yet is often unrecognized. A comprehensive and sequential intervention (CSI) aiming to effect change in clinician behavior by improving knowledge about delirium was tested. Design and Methods: A 2-day CSI program that consisted of progressive 4-part didactic series,…

  17. Comparison of three noninvasive methods for hemoglobin screening of blood donors.

    PubMed

    Ardin, Sergey; Störmer, Melanie; Radojska, Stela; Oustianskaia, Larissa; Hahn, Moritz; Gathof, Birgit S

    2015-02-01

    To prevent phlebotomy of anemic individuals and to ensure hemoglobin (Hb) content of the blood units, Hb screening of blood donors before donation is essential. Hb values are mostly evaluated by measurement of capillary blood obtained from fingerstick. Rapid noninvasive methods have recently become available and may be preferred by donors and staff. The aim of this study was to evaluate for the first time all different noninvasive methods for Hb screening. Blood donors were screened for Hb levels in three different trials using three different noninvasive methods (Haemospect [MBR Optical Systems GmbH & Co. KG], NBM 200 [LMB Technology GmbH], Pronto-7 [Masimo Europe Ltd]) in comparison to the established fingerstick method (CompoLab Hb [Fresenius Kabi GmbH]) and to levels obtained from venous samples on a cell counter (Sysmex [Sysmex Europe GmbH]) as reference. The usability of the noninvasive methods was assessed with an especially developed survey. Technical failures occurred by using the Pronto-7 due to nail polish, skin color, or ambient light. The NBM 200 also showed a high sensitivity to ambient light and noticeably lower Hb levels for women than obtained from the Sysmex. The statistical analysis showed the following bias and standard deviation of differences of all methods in comparison to the venous results: Haemospect, -0.22 ± 1.24; NBM, 200 -0.12 ± 1.14; Pronto-7, -0.50 ± 0.99; and CompoLab Hb, -0.53 ± 0.81. Noninvasive Hb tests represent an attractive alternative by eliminating pain and reducing risks of blood contamination. The main problem for generating reliable results seems to be preanalytical variability in sampling. Despite the sensitivity to environmental stress, all methods are suitable for Hb measurement. © 2014 AABB.

  18. Invention and validation of an automated camera system that uses optical character recognition to identify patient name mislabeled samples.

    PubMed

    Hawker, Charles D; McCarthy, William; Cleveland, David; Messinger, Bonnie L

    2014-03-01

    Mislabeled samples are a serious problem in most clinical laboratories. Published error rates range from 0.39/1000 to as high as 1.12%. Standardization of bar codes and label formats has not yet achieved the needed improvement. The mislabel rate in our laboratory, although low compared with published rates, prompted us to seek a solution to achieve zero errors. To reduce or eliminate our mislabeled samples, we invented an automated device using 4 cameras to photograph the outside of a sample tube. The system uses optical character recognition (OCR) to look for discrepancies between the patient name in our laboratory information system (LIS) vs the patient name on the customer label. All discrepancies detected by the system's software then require human inspection. The system was installed on our automated track and validated with production samples. We obtained 1 009 830 images during the validation period, and every image was reviewed. OCR passed approximately 75% of the samples, and no mislabeled samples were passed. The 25% failed by the system included 121 samples actually mislabeled by patient name and 148 samples with spelling discrepancies between the patient name on the customer label and the patient name in our LIS. Only 71 of the 121 mislabeled samples detected by OCR were found through our normal quality assurance process. We have invented an automated camera system that uses OCR technology to identify potential mislabeled samples. We have validated this system using samples transported on our automated track. Full implementation of this technology offers the possibility of zero mislabeled samples in the preanalytic stage.

  19. Quality performance of laboratory testing in pharmacies: a collaborative evaluation.

    PubMed

    Zaninotto, Martina; Miolo, Giorgia; Guiotto, Adriano; Marton, Silvia; Plebani, Mario

    2016-11-01

    The quality performance and the comparability between results of pharmacies point-of-care-testing (POCT) and institutional laboratories have been evaluated. Eight pharmacies participated in the project: a capillary specimen collected by the pharmacist and, simultaneously, a lithium-heparin sample drawn by a physician of laboratory medicine for the pharmacy customers (n=106) were analyzed in the pharmacy and in the laboratory, respectively. Glucose, cholesterol, HDL-cholesterol, triglycerides, creatinine, uric acid, aspartate aminotransferase, alanine aminotransferase, were measured using: Reflotron, n=5; Samsung, n=1; Cardiocheck PA, n=1; Cholestech LDX, n=1 and Cobas 8000. The POCT analytical performance only (phase 2) were evaluated testing, in pharmacies and in the laboratory, the lithium heparin samples from a female drawn fasting daily in a week, and a control sample containing high concentrations of glucose, cholesterol and triglycerides. For all parameters, except triglycerides, the slopes showed a satisfactory correlation. For triglycerides, a median value higher in POCT in comparison to the laboratory (1.627 mmol/L vs. 0.950 mmol/L) has been observed. The agreement in the subjects classification, demonstrates that for glucose, 70% of the subjects show concentrations below the POCT recommended level (5.8-6.1 mmol/L), while 56% are according to the laboratory limit (<5.6 mmol/L). Total cholesterol exhibits a similar trend while POCT triglycerides show a greater percentage of increased values (21% vs. 9%). The reduction in triglycerides bias (phase 2) suggests that differences between POCT and central laboratory is attributable to a pre-analytical problem. The results confirm the acceptable analytical performance of POCT pharmacies and specific criticisms in the pre- and post-analytical phases.

  20. Effectiveness of Preanalytic Practices on Contamination and Diagnostic Accuracy of Urine Cultures: a Laboratory Medicine Best Practices Systematic Review and Meta-analysis

    PubMed Central

    Franek, Jacob; Leibach, Elizabeth K.; Weissfeld, Alice S.; Kraft, Colleen S.; Sautter, Robert L.; Baselski, Vickie; Rodahl, Debra; Peterson, Edward J.; Cornish, Nancy E.

    2015-01-01

    SUMMARY Background. Urinary tract infection (UTI) in the United States is the most common bacterial infection, and urine cultures often make up the largest portion of workload for a hospital-based microbiology laboratory. Appropriately managing the factors affecting the preanalytic phase of urine culture contributes significantly to the generation of meaningful culture results that ultimately affect patient diagnosis and management. Urine culture contamination can be reduced with proper techniques for urine collection, preservation, storage, and transport, the major factors affecting the preanalytic phase of urine culture. Objectives. The purposes of this review were to identify and evaluate preanalytic practices associated with urine specimens and to assess their impact on the accuracy of urine culture microbiology. Specific practices included collection methods for men, women, and children; preservation of urine samples in boric acid solutions; and the effect of refrigeration on stored urine. Practice efficacy and effectiveness were measured by two parameters: reduction of urine culture contamination and increased accuracy of patient diagnosis. The CDC Laboratory Medicine Best Practices (LMBP) initiative's systematic review method for assessment of quality improvement (QI) practices was employed. Results were then translated into evidence-based practice guidelines. Search strategy. A search of three electronic bibliographic databases (PubMed, SCOPUS, and CINAHL), as well as hand searching of bibliographies from relevant information sources, for English-language articles published between 1965 and 2014 was conducted. Selection criteria. The search contained the following medical subject headings and key text words: urinary tract infections, UTI, urine/analysis, urine/microbiology, urinalysis, specimen handling, preservation, biological, preservation, boric acid, boric acid/borate, refrigeration, storage, time factors, transportation, transport time, time delay, time factor, timing, urine specimen collection, catheters, indwelling, urinary reservoirs, continent, urinary catheterization, intermittent urethral catheterization, clean voided, midstream, Foley, suprapubic, bacteriological techniques, and microbiological techniques. Main results. Both boric acid and refrigeration adequately preserved urine specimens prior to their processing for up to 24 h. Urine held at room temperature for more than 4 h showed overgrowth of both clinically significant and contaminating microorganisms. The overall strength of this body of evidence, however, was rated as low. For urine specimens collected from women, there was no difference in rates of contamination for midstream urine specimens collected with or without cleansing. The overall strength of this evidence was rated as high. The levels of diagnostic accuracy of midstream urine collection with or without cleansing were similar, although the overall strength of this evidence was rated as low. For urine specimens collected from men, there was a reduction in contamination in favor of midstream clean-catch over first-void specimen collection. The strength of this evidence was rated as high. Only one study compared midstream collection with cleansing to midstream collection without cleansing. Results showed no difference in contamination between the two methods of collection. However, imprecision was due largely to the small event size. The diagnostic accuracy of midstream urine collection from men compared to straight catheterization or suprapubic aspiration was high. However, the overall strength of this body of evidence was rated as low. For urine specimens collected from children and infants, the evidence comparing contamination rates for midstream urine collection with cleansing, midstream collection without cleansing, sterile urine bag collection, and diaper collection pointed to larger reductions in the odds of contamination in favor of midstream collection with cleansing over the other methods of collection. This body of evidence was rated as high. The accuracy of diagnosis of urinary tract infection from midstream clean-catch urine specimens, sterile urine bag specimens, or diaper specimens compared to straight catheterization or suprapubic aspiration was varied. Authors' conclusions. No recommendation for or against is made for delayed processing of urine stored at room temperature, refrigerated, or preserved in boric acid. This does not preclude the use of refrigeration or chemical preservatives in clinical practice. It does indicate, however, that more systematic studies evaluating the utility of these measures are needed. If noninvasive collection is being considered for women, midstream collection with cleansing is recommended, but no recommendation for or against is made for midstream collection without cleansing. If noninvasive collection is being considered for men, midstream collection with cleansing is recommended and collection of first-void urine is not recommended. No recommendation for or against is made for collection of midstream urine without cleansing. If noninvasive collection is being considered for children, midstream collection with cleansing is recommended and collection in sterile urine bags, from diapers, or midstream without cleansing is not recommended. Whether midstream collection with cleansing can be routinely used in place of catheterization or suprapubic aspiration is unclear. The data suggest that midstream collection with cleansing is accurate for the diagnosis of urinary tract infections in infants and children and has higher average accuracy than sterile urine bag collection (data for diaper collection were lacking); however, the overall strength of evidence was low, as multivariate modeling could not be performed, and thus no recommendation for or against can be made. PMID:26598386

  1. Identifying and Assessing Interesting Subgroups in a Heterogeneous Population.

    PubMed

    Lee, Woojoo; Alexeyenko, Andrey; Pernemalm, Maria; Guegan, Justine; Dessen, Philippe; Lazar, Vladimir; Lehtiö, Janne; Pawitan, Yudi

    2015-01-01

    Biological heterogeneity is common in many diseases and it is often the reason for therapeutic failures. Thus, there is great interest in classifying a disease into subtypes that have clinical significance in terms of prognosis or therapy response. One of the most popular methods to uncover unrecognized subtypes is cluster analysis. However, classical clustering methods such as k-means clustering or hierarchical clustering are not guaranteed to produce clinically interesting subtypes. This could be because the main statistical variability--the basis of cluster generation--is dominated by genes not associated with the clinical phenotype of interest. Furthermore, a strong prognostic factor might be relevant for a certain subgroup but not for the whole population; thus an analysis of the whole sample may not reveal this prognostic factor. To address these problems we investigate methods to identify and assess clinically interesting subgroups in a heterogeneous population. The identification step uses a clustering algorithm and to assess significance we use a false discovery rate- (FDR-) based measure. Under the heterogeneity condition the standard FDR estimate is shown to overestimate the true FDR value, but this is remedied by an improved FDR estimation procedure. As illustrations, two real data examples from gene expression studies of lung cancer are provided.

  2. Role of zircon in tracing crustal growth and recycling

    NASA Astrophysics Data System (ADS)

    Compston, W.; Williams, I. S.; Armstrong, R. A.; Claoue-Long, J. C.; Kinny, P. D.; Foster, J. J.; Kroener, A.; Pidgeon, R. T.; Myers, J. S.

    Single crystal ion probe ages of zircons is discussed, which allow much better time resolution compared to other geochronological methods, although the technique is not without problems. Rocks from two areas that contain composite zircon populations, including true magmatic zircons as well as a variety of xenocrystic types are described. It is often difficult to distinguish these; xenocrystic zircons, for example, cannot always be identified on the basis of morphology alone. Additional evidence is needed before making age interpretations. Evidence is also presented of zircon growth long after the original time of crystallization, in some cases apparently at temperatures less than 300 C. The spectacular discovery of 4.1 to 4.2 Ga detrital zircons in metaquartzites from the Mount Narryer area of Western Australia is described. Similar zircons with ages as old as 4276 Ma have been found in the nearby Jack Hills area. The source areas or parent lithologies of these zircons have not yet been determined, but the author expects that they may be unrecognized or buried antecedents of the K rich Narryer gneisses. U or Th concentrations of zircon cannot be used to discriminate between felsic and mafic source rocks.

  3. Glacial sediment causing regional-scale elevated arsenic in drinking water.

    PubMed

    Erickson, Melinda L; Barnes, Randal J

    2005-01-01

    In the upper Midwest, USA, elevated arsenic concentrations in public drinking water systems are associated with the lateral extent of northwest provenance late Wisconsin-aged drift. Twelve percent of public water systems located within the footprint of this drift (212 of 1764) exceed 10 microg/L arsenic, which is the U.S. EPA's drinking water standard. Outside of the footprint, only 2.4% of public water systems (52 of 2182) exceed 10 microg/L arsenic. Both glacial drift aquifers and shallow bedrock aquifers overlain by northwest provenance late Wisconsin-aged sediment are affected by arsenic contamination. Evidence suggests that the distinct physical characteristics of northwest provenance late Wisconsin-aged drift--its fine-grained matrix and entrained organic carbon that fosters biological activity--cause the geochemical conditions necessary to mobilize arsenic via reductive mechanisms such as reductive desorption and reductive dissolution of metal oxides. This study highlights an important and often unrecognized phenomenon: high-arsenic sediment is not necessary to cause arsenic-impacted ground water--when "impacted" is now defined as >10 microg/L. This analysis also demonstrates the scientific and economic value of using existing large but imperfect statewide data sets to observe and characterize regional-scale environmental problems.

  4. [Human African trypanosomiasis: report of three cases].

    PubMed

    Koko, J; Ategbo, S J; Gahouma, D; Engohan-Aloghe, E; Moussavou, A

    2013-08-01

    Prolonged fever is an important cause of morbidity in pediatric practice, especially in tropical areas. It is above all a problem of etiological diagnosis given the vast number of etiologies. In sub-Saharan Africa, practitioners more often focus on bacterial infections and malaria at the expense of other infectious diseases such as human African trypanosomiasis (HAT), most often leading to overuse of antibiotics and antimalarials. A dramatic resurgence of HAT, also called sleeping sickness, has been reported during the last few decades in large areas of Central Africa. Furthermore, with the development of air transport, cases of children infected during a trip to Africa can be exported outside endemic areas, making diagnosis even more difficult. This parasitic infection causes a protracted, often initially unrecognized, illness with episodes of fever, headache, and malaise, accompanied by progressive lymphadenopathy, before the development of a progressive meningoencephalitis. These three case reports aim to remind practitioners of clinical and biological signs suggestive of HAT diagnosis in children living in endemic areas or having stayed there during the months prior to visiting the doctor. The prognosis is largely dependent on the precocity of diagnosis and therapeutic support. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  5. Incorporating uncertainty in predictive species distribution modelling.

    PubMed

    Beale, Colin M; Lennon, Jack J

    2012-01-19

    Motivated by the need to solve ecological problems (climate change, habitat fragmentation and biological invasions), there has been increasing interest in species distribution models (SDMs). Predictions from these models inform conservation policy, invasive species management and disease-control measures. However, predictions are subject to uncertainty, the degree and source of which is often unrecognized. Here, we review the SDM literature in the context of uncertainty, focusing on three main classes of SDM: niche-based models, demographic models and process-based models. We identify sources of uncertainty for each class and discuss how uncertainty can be minimized or included in the modelling process to give realistic measures of confidence around predictions. Because this has typically not been performed, we conclude that uncertainty in SDMs has often been underestimated and a false precision assigned to predictions of geographical distribution. We identify areas where development of new statistical tools will improve predictions from distribution models, notably the development of hierarchical models that link different types of distribution model and their attendant uncertainties across spatial scales. Finally, we discuss the need to develop more defensible methods for assessing predictive performance, quantifying model goodness-of-fit and for assessing the significance of model covariates.

  6. Human behavior recognition using a context-free grammar

    NASA Astrophysics Data System (ADS)

    Rosani, Andrea; Conci, Nicola; De Natale, Francesco G. B.

    2014-05-01

    Automatic recognition of human activities and behaviors is still a challenging problem for many reasons, including limited accuracy of the data acquired by sensing devices, high variability of human behaviors, and gap between visual appearance and scene semantics. Symbolic approaches can significantly simplify the analysis and turn raw data into chains of meaningful patterns. This allows getting rid of most of the clutter produced by low-level processing operations, embedding significant contextual information into the data, as well as using simple syntactic approaches to perform the matching between incoming sequences and models. We propose a symbolic approach to learn and detect complex activities through the sequences of atomic actions. Compared to previous methods based on context-free grammars, we introduce several important novelties, such as the capability to learn actions based on both positive and negative samples, the possibility of efficiently retraining the system in the presence of misclassified or unrecognized events, and the use of a parsing procedure that allows correct detection of the activities also when they are concatenated and/or nested one with each other. An experimental validation on three datasets with different characteristics demonstrates the robustness of the approach in classifying complex human behaviors.

  7. Short-term exposure to dimethylformamide and the impact on digestive system disease: an outdoor study for volatile organic compound.

    PubMed

    Wang, Cui; Huang, Canke; Wei, Yumei; Zhu, Qi; Tian, Weili; Zhang, Qingyu

    2014-07-01

    Occupational and experimental studies have revealed the organs most affected by dimethylformamide (DMF) are liver and gastrointestinal tract. However, few studies have focused on the potential effect of outdoor pollution of DMF. This study examined the health risk of hospitalization due to digestive system disease by time series studies in a case city Longwan, China. The urine metabolite of DMF was correlated well with DMF exposure concentration (EC). A 101.0-μg/m(3) (interquartile range) increase in the two-day moving average of DMF EC was associated with a 1.10 (1.01 ˜ 1.20), 1.22 (1.10 ˜ 1.35), and 1.05 (0.90 ˜ 1.22) increase in hospitalization for total digestive system diseases, liver disease, and gastrointestinal tract disease, respectively. The exposure-dose response between DMF and the relative risk of liver disease was linear only below 350 μg/m(3). These findings highlight a previously unrecognized health problem related to VOCs released into the outdoor environment. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Reliability of infarct volumetry: Its relevance and the improvement by a software-assisted approach.

    PubMed

    Friedländer, Felix; Bohmann, Ferdinand; Brunkhorst, Max; Chae, Ju-Hee; Devraj, Kavi; Köhler, Yvette; Kraft, Peter; Kuhn, Hannah; Lucaciu, Alexandra; Luger, Sebastian; Pfeilschifter, Waltraud; Sadler, Rebecca; Liesz, Arthur; Scholtyschik, Karolina; Stolz, Leonie; Vutukuri, Rajkumar; Brunkhorst, Robert

    2017-08-01

    Despite the efficacy of neuroprotective approaches in animal models of stroke, their translation has so far failed from bench to bedside. One reason is presumed to be a low quality of preclinical study design, leading to bias and a low a priori power. In this study, we propose that the key read-out of experimental stroke studies, the volume of the ischemic damage as commonly measured by free-handed planimetry of TTC-stained brain sections, is subject to an unrecognized low inter-rater and test-retest reliability with strong implications for statistical power and bias. As an alternative approach, we suggest a simple, open-source, software-assisted method, taking advantage of automatic-thresholding techniques. The validity and the improvement of reliability by an automated method to tMCAO infarct volumetry are demonstrated. In addition, we show the probable consequences of increased reliability for precision, p-values, effect inflation, and power calculation, exemplified by a systematic analysis of experimental stroke studies published in the year 2015. Our study reveals an underappreciated quality problem in translational stroke research and suggests that software-assisted infarct volumetry might help to improve reproducibility and therefore the robustness of bench to bedside translation.

  9. Structure of a Reptilian Adenovirus Reveals a Phage Tailspike Fold Stabilizing a Vertebrate Virus Capsid.

    PubMed

    Menéndez-Conejero, Rosa; Nguyen, Thanh H; Singh, Abhimanyu K; Condezo, Gabriela N; Marschang, Rachel E; van Raaij, Mark J; San Martín, Carmen

    2017-10-03

    Although non-human adenoviruses (AdVs) might offer solutions to problems posed by human AdVs as therapeutic vectors, little is known about their basic biology. In particular, there are no structural studies on the complete virion of any AdV with a non-mammalian host. We combine mass spectrometry, cryo-electron microscopy, and protein crystallography to characterize the composition and structure of a snake AdV (SnAdV-1, Atadenovirus genus). SnAdV-1 particles contain the genus-specific proteins LH3, p32k, and LH2, a previously unrecognized structural component. Remarkably, the cementing protein LH3 has a trimeric β helix fold typical of bacteriophage host attachment proteins. The organization of minor coat proteins differs from that in human AdVs, correlating with higher thermostability in SnAdV-1. These findings add a new piece to the intriguing puzzle of virus evolution, hint at the use of cell entry pathways different from those in human AdVs, and will help development of new, thermostable SnAdV-1-based vectors. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. The importance of multilocus sequence typing: cautionary tales from the bacterium Xylella fastidiosa.

    PubMed

    Nunney, L; Elfekih, S; Stouthamer, R

    2012-05-01

    Microbial identification methods have evolved rapidly over the last few decades. One such method is multilocus sequence typing (MLST). MLST is a powerful tool for understanding the evolutionary dynamics of pathogens and to gain insight into their genetic diversity. We illustrate the importance of accurate typing by reporting on three problems that have arisen in the study of a single bacterial species, the plant pathogen Xylella fastidiosa. Two of these were particularly serious since they concerned contamination of important research material that has had detrimental consequences for Xylella research: the contamination of DNA used in the sequencing of an X. fastidiosa genome (Ann-1) with DNA from another X. fastidiosa strain, and the unrecognized mislabeling of a strain (Temecula1) distributed from a culture collection (ATCC). We advocate the routine use of MLST to define strains maintained in culture collections and emphasize the importance of confirming the purity of DNA submitted for sequencing. We also present a third example that illustrates the value of MLST in guiding the choice of taxonomic types. Beyond these situations, there is a strong case for MLST whenever an isolate is used experimentally, especially where genotypic differences are suspected to influence the outcome.

  11. The work impact of dysthymia in a primary care population

    PubMed Central

    Adler, David A.; Irish, Julie; McLaughlin, Thomas J.; Perissinotto, Carla; Chang, Hong; Hood, Maggie; Lapitsky, Leueen; Rogers, William H.; Lerner, Debra

    2014-01-01

    Physicians regard individuals with dysthymia as having relatively normal levels of functioning. This study examines in detail the work impact of dysthymia in a population of employed primary care patients. As part of an observational study conducted between 2001 and 2003 in clinics associated with three health plans in Massachusetts, we compared 69 patients diagnosed with DSM-IV dysthymia without concurrent major depressive disorder to 175 depression-free controls. Patients were employed at least 15 h per week, had no immediate plans to leave the labor market, and no major comorbid medical conditions. We assessed work absences and productivity loss due to on-the-job performance limitations (“presenteeism”). Patients with dysthymia, compared with controls, had less stable work histories and a greater frequency of significant problems at work. While absence rates were not significantly different (1.2 vs. 0.74 days, P < .09), individuals with dysthymia experienced significantly greater on-the-job productivity loss (6.3% vs. 2.8%, P < .0001). Dysthymia is an unrecognized cause of work impairment that has long-term negative consequences for individuals and their employers. The persistence of dysthymia with its serious impact on work functioning calls out for the development of new interventions. PMID:15234821

  12. Role of zircon in tracing crustal growth and recycling

    NASA Technical Reports Server (NTRS)

    Compston, W.; Williams, I. S.; Armstrong, R. A.; Claoue-Long, J. C.; Kinny, P. D.; Foster, J. J.; Kroener, A.; Pidgeon, R. T.; Myers, J. S.

    1988-01-01

    Single crystal ion probe ages of zircons is discussed, which allow much better time resolution compared to other geochronological methods, although the technique is not without problems. Rocks from two areas that contain composite zircon populations, including true magmatic zircons as well as a variety of xenocrystic types are described. It is often difficult to distinguish these; xenocrystic zircons, for example, cannot always be identified on the basis of morphology alone. Additional evidence is needed before making age interpretations. Evidence is also presented of zircon growth long after the original time of crystallization, in some cases apparently at temperatures less than 300 C. The spectacular discovery of 4.1 to 4.2 Ga detrital zircons in metaquartzites from the Mount Narryer area of Western Australia is described. Similar zircons with ages as old as 4276 Ma have been found in the nearby Jack Hills area. The source areas or parent lithologies of these zircons have not yet been determined, but the author expects that they may be unrecognized or buried antecedents of the K rich Narryer gneisses. U or Th concentrations of zircon cannot be used to discriminate between felsic and mafic source rocks.

  13. The health needs of young people in prison.

    PubMed

    Lennox, Charlotte

    2014-12-01

    There has been an unprecedented reduction in the number of young people in prison; however, questions remain about the appropriateness and effectiveness of custody, given the high prevalence of health needs, self-inflected deaths while in custody and high reoffending rates. Articles relating to the health needs of young people, aged 10-17 years in prison in England and Wales were sourced through PubMed and ISI Web of Knowledge, plus additional key reports were included if deemed relevant. Young people in prison have much higher rates of multiple and complex health problems compared with young people in the general population. However, many of their health-care needs are unrecognized and unmet. There is an urgent need for up-to-date and robust prevalence data of all health needs across the age ranges in England and Wales. Research has neglected physical health and neurodevelopmental disorders and the quality of research for females and Black and Minority Ethnic group's requires improvement. There is a dearth of high-quality evaluations of health interventions with robust and sensitive short- and long-term outcome measures. © The Author 2014. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  14. Metagenomics: A Call for Bringing a New Science into the Classroom (While It's Still New)

    ERIC Educational Resources Information Center

    Jurkowski, Anne; Reid, Ann H.; Labov, Jay B.

    2007-01-01

    This article describes the emerging field of metagenomics, a potent new tool that vastly expands the ability of scientists to study the myriad capabilities of microbial communities and the as yet unrecognized relationships and interactions of microbes with other forms of life and the environment. The birth of this exciting new field provides the…

  15. James Baldwin's "Everybody's Protest Novel": Educating Our Responses to Racism

    ERIC Educational Resources Information Center

    Frank, Jeff

    2014-01-01

    The aim of this article is to establish--and explore--James Baldwin's significance for educational theory. Through a close reading of "Everybody's Protest Novel", I show that Baldwin's thinking is an important (if unrecognized) precursor to the work of Stanley Cavell and Cora Diamond, and is relevant to a number of…

  16. Invisible metallic microfiber in clothing presents unrecognized MRI risk for cutaneous burn.

    PubMed

    Pietryga, J A; Fonder, M A; Rogg, J M; North, D L; Bercovitch, L G

    2013-05-01

    We report a case of a thermal burn that occurred during MR imaging likely caused by invisible silver-embedded microfibers in the fabric of an undershirt. As the prevalence of fabric containing nondetectable metallic microfiber increases in athletic and "tech" clothing, the importance of having patients change into safe facility-provided garments before MR imaging is emphasized.

  17. The History of the Discovery of Blood Circulation: Unrecognized Contributions of Ayurveda Masters

    ERIC Educational Resources Information Center

    Patwardhan, Kishor

    2012-01-01

    Ayurveda, the native healthcare system of India, is a rich resource of well-documented ancient medical knowledge. Although the roots of this knowledge date back to the Vedic and post-Vedic eras, it is generally believed that a dedicated branch for healthcare was gradually established approximately between 400 BCE and 200 CE. Probably because the…

  18. [Hydrocholecystis, unrecognized cause of painful abdominal crises in patients with sickle cell anemia].

    PubMed

    Cabrol, S; Desjardin, F; Baruchel, S; Bégué, P; Cordier, M D; Lasfargues, G

    1985-12-01

    The first case of painful abdominal crisis caused by hydrops of the gallbladder during sickle cell disease is reported. The cholecystosonography allowed diagnosis and supervision in a 4 year-old black boy with sickle cell anemia. The persistence of hydrops led to cholecystectomy. Pathophysiology is discussed according to the other etiologies reported in the literature.

  19. Hereditary neuropathy with liability to pressure palsies occurring during military training.

    PubMed

    Delacour, H; Bompaire, F; Biale, L; Sallansonnet-Froment, M; Ceppa, F; Burnat, P

    2012-03-01

    Hereditary neuropathy with liability to pressure palsies (HNPP) is an autosomal-dominant peripheral neuropathy characterized by recurrent isolated nerve palsies, which are precipitated by trivial compression and trauma. Although HNPP has been well-described in literature, it often goes unrecognized. We report a case of HNPP occurring during military training to promote recognition and proper management of this entity.

  20. The Law and Health Personnel; A Study of Minnesota Law Related to Selected Health Manpower Categories.

    ERIC Educational Resources Information Center

    American Rehabilitation Foundation, Minneapolis, Minn. Inst. for Interdisciplinary Studies.

    This report surveys Minnesota laws relating to the use of health manpower. It presents a summary of Minnesota licensure laws as they apply to categories of health personnel and paramedical personnel currently unrecognized by the law. An analysis is also made of malpractice decisional law to examine whether such laws prohibit or inhibit optimal…

Top